Sample records for aerosols carbon monoxide

  1. Seasonal variations in elemental carbon aerosol, carbon monoxide and sulfur dioxide: Implications for sources

    NASA Astrophysics Data System (ADS)

    Antony Chen, L.-W.; Doddridge, Bruce G.; Dickerson, Russell R.; Chow, Judith C.; Mueller, Peter K.; Quinn, John; Butler, William A.

    As part of Maryland Aerosol Research and CHaracterization (MARCH-Atlantic) study, measurements of 24-hr average elemental carbon (EC) aerosol concentration were made at Fort Meade, Maryland, USA, a suburban site within the Baltimore-Washington corridor during July 1999, October 1999, January 2000, April 2000 and July 2000. Carbon monoxide (CO) and sulfur dioxide (SO2) were also measured nearly continuously over the period. Tight correlation between EC and CO in every month suggests common or proximate sources, likely traffic emissions. The EC versus CO slope varies in different seasons and generally increases with ambient temperature. The temperature dependence of EC/CO ratios suggests that EC source strength peaks in summer. By using the well established emission inventory for CO, and EC/CO ratio found in this study, EC emission over North America is estimated at 0.31±0.12 Tg yr-1, on the low end but in reasonable agreement with prior inventories based on emission factors and fuel consumption.

  2. Seasonal variations in elemental carbon aerosol, carbon monoxide and sulfur dioxide: Implications for sources

    NASA Astrophysics Data System (ADS)

    Chen, L.-W. Antony; Doddridge, Bruce G.; Dickerson, Russell R.; Chow, Judith C.; Mueller, Peter K.; Quinn, John; Butler, William A.

    2001-05-01

    As part of Maryland Aerosol Research and CHaracterization (MARCH-Atlantic) study, measurements of 24-hr average elemental carbon (EC) aerosol concentration were made at Fort Meade, Maryland, USA, a suburban site within the Baltimore-Washington corridor during July 1999, October 1999, January 2000, April 2000 and July 2000. Carbon monoxide (CO) and sulfur dioxide (SO2) were also measured nearly continuously over the period. Tight correlation between EC and CO in every month suggests common or proximate sources, likely traffic emissions. The EC versus CO slope varies in different seasons and generally increases with ambient temperature. The temperature dependence of EC/CO ratios suggests that EC source strength peaks in summer. By using the well established emission inventory for CO, and EC/CO ratio found in this study, EC emission over North America is estimated at 0.31+/-0.12Tgyr-1, on the low end but in reasonable agreement with prior inventories based on emission factors and fuel consumption.

  3. Quantifying Wildfire Emissions and associated Aerosol Species using Assimilation of Satellite Carbon Monoxide Retrievals

    NASA Astrophysics Data System (ADS)

    Edwards, David; Barre, Jerome; Worden, Helen; Gaubert, Benjamin

    2017-04-01

    Intense and costly wildfires tend are predicted to increase in frequency under a warming climate. For example, the recent August 2015 Washington State fires were the largest in the state's history. Also in September and October 2015 very intense fires over Indonesia produced some of the highest concentrations of carbon monoxide (CO) ever seen from satellite. Such larges fires impact not only the local environment but also affect air quality far downwind through the long-range transport of pollutants. Global to continental scale coverage showing the evolution of CO resulting from fire emission is available from satellite observations. Carbon monoxide is the only atmospheric trace gas for which satellite multispectral retrievals have demonstrated reliable independent profile information close to the surface and also higher in the free troposphere. The unique CO profile product from Terra/MOPITT clearly distinguishes near-surface CO from the free troposphere CO. Also previous studies have suggested strong correlations between primary emissions of fire organic and black carbon aerosols and CO. We will present results from the Ensemble Adjustement Kalman Filter (DART) system that has been developed to assimilate MOPITT CO in the global-scale chemistry-climate model CAM-Chem. The ensemble technique allows inference on various fire model state variables such as CO emissions, and also aerosol species resulting from fires such as organic and black carbon. The benefit of MOPITT CO profile assimilation for estimating the CO emissions from the Washington and Indonesian fire cases will be discussed, along with the ability of the ensemble approach to infer information on the black and organic carbon aerosol distribution. This study builds on capability to quantitatively integrate satellite observations and models developed in recent years through projects funded by the NASA ACMAP Program.

  4. Quantifying fire emissions and associated aerosols species using assimilation of satellite carbon monoxide retrievals.

    NASA Astrophysics Data System (ADS)

    Barre, J.; Edwards, D. P.; Worden, H. M.

    2016-12-01

    Wildfires tend to be more intense and hence costly and are predicted to increase in frequency under a warming climate. For example, the recent August 2015 Washington State fires were the largest in the state's history. Also in September and October 2015 very intense fires over Indonesia produced some of the highest concentration of carbon monoxide (CO) ever seen from space. Such larges fires impact not only the local environment but also affects air quality far downwind through the long-range transport of pollutants. Global to continental scale coverage showing the evolution of CO resulting from fire emission is available from satellite observations. Carbon monoxide is the only atmospheric trace gas for which satellite multispectral retrievals have demonstrated reliable independent profile information close to the surface and also higher in the free troposphere. The unique CO profile product from Terra/MOPITT clearly distinguishes near-surface CO from the free troposphere CO. Also previous studies have suggested strong correlations between primary emissions of fire organic and black carbon aerosols and CO. We will present results from the Ensemble Adjustement Kalman Filter (DART) system that has been developed to assimilate MOPITT CO in the global scale chemistry-climate model CAM-Chem. The ensemble technique allows inference on various fire model state variables such as CO emissions and also aerosol species resulting from fires such as organic and black carbon. The benefit of MOPITT CO assimilation on the Washington and Indonesian fire cases studies will be diagnosed regarding the CO fire emissions, black and organic carbon inference using the ensemble information.

  5. Carbon Monoxide Toxicity

    PubMed Central

    Aniol, Michael J.

    1992-01-01

    Of all fatal poisonings in the United States, an estimated half are due to carbon monoxide. The number of non-lethal poisonings due to carbon monoxide is difficult to estimate because signs and symptoms of carbon monoxide poisoning cover a wide spectrum and mimic other disorders. Misdiagnosis is serious, as the patient often returns to the contaminated environment. Those not receiving proper treatment are at significant risk, as high as 10% to 12%, of developing late neurological sequelae. The diagnosis of carbon monoxide poisoning depends upon precise history taking, careful physical examination, and a high index of suspicion. ImagesFigure 2 PMID:21221282

  6. Carbon Monoxide Information Center

    MedlinePlus Videos and Cool Tools

    ... Education Centers Carbon Monoxide Information Center Carbon Monoxide Information Center En Español The Invisible Killer Carbon monoxide, ... Install one and check its batteries regularly. View Information About CO Alarms Other CO Topics Safety Tips ...

  7. Carbon Monoxide Poisoning - Multiple Languages

    MedlinePlus

    ... Prevention Guidelines: You Can Prevent Carbon Monoxide Exposure - English PDF Prevention Guidelines: You Can Prevent Carbon Monoxide ... Expand Section Carbon Monoxide - Furnace Safety Fact Sheet - English PDF Carbon Monoxide - Furnace Safety Fact Sheet - العربية ( ...

  8. Carbon Monoxide (CO)

    MedlinePlus

    ... burning appliances -- including furnaces, stoves, fireplaces, clothes dryers, water heaters, and space heaters -- to detect deadly carbon monoxide leaks. Underwriters' Laboratory Product Safety Tips - Carbon Monoxide Alarms ...

  9. Solid State Carbon Monoxide Sensor

    NASA Technical Reports Server (NTRS)

    Upchurch, Billy T. (Inventor); Wood, George M. (Inventor); Schryer, David R. (Inventor); Leighty, Bradley D. (Inventor); Oglesby, Donald M. (Inventor); Kielin, Erik J. (Inventor); Brown, Kenneth G. (Inventor); DAmbrosia, Christine M. (Inventor)

    1999-01-01

    A means for detecting carbon monoxide which utilizes an un-heated catalytic material to oxidize carbon monoxide at ambient temperatures. Because this reaction is exothermic, a thermistor in contact with the catalytic material is used as a sensing element to detect the heat evolved as carbon monoxide is oxidized to carbon dioxide at the catalyst surface, without any heaters or external heating elements for the ambient air or catalytic element material. Upon comparison to a reference thermistor, relative increases in the temperature of the sensing thermistor correspond positively with an increased concentration of carbon monoxide in the ambient medium and are thus used as an indicator of the presence of carbon monoxide.

  10. Occult Carbon Monoxide Poisoning

    PubMed Central

    Kirkpatrick, John N.

    1987-01-01

    A syndrome of headache, fatigue, dizziness, paresthesias, chest pain, palpitations and visual disturbances was associated with chronic occult carbon monoxide exposure in 26 patients in a primary care setting. A causal association was supported by finding a source of carbon monoxide in a patient's home, workplace or vehicle; results of screening tests that ruled out other illnesses; an abnormally high carboxyhemoglobin level in 11 of 14 patients tested, and abatement or resolution of symptoms when the source of carbon monoxide was removed. Exposed household pets provided an important clue to the diagnosis in some cases. Recurrent occult carbon monoxide poisoning may be a frequently overlooked cause of persistent or recurrent headache, fatigue, dizziness, paresthesias, abdominal pain, diarrhea and unusual spells. PMID:3825110

  11. Occult carbon monoxide poisoning.

    PubMed

    Kirkpatrick, J N

    1987-01-01

    A syndrome of headache, fatigue, dizziness, paresthesias, chest pain, palpitations and visual disturbances was associated with chronic occult carbon monoxide exposure in 26 patients in a primary care setting. A causal association was supported by finding a source of carbon monoxide in a patient's home, workplace or vehicle; results of screening tests that ruled out other illnesses; an abnormally high carboxyhemoglobin level in 11 of 14 patients tested, and abatement or resolution of symptoms when the source of carbon monoxide was removed. Exposed household pets provided an important clue to the diagnosis in some cases. Recurrent occult carbon monoxide poisoning may be a frequently overlooked cause of persistent or recurrent headache, fatigue, dizziness, paresthesias, abdominal pain, diarrhea and unusual spells.

  12. Black carbon in aerosol during BIBLE B

    NASA Astrophysics Data System (ADS)

    Liley, J. Ben; Baumgardner, D.; Kondo, Y.; Kita, K.; Blake, D. R.; Koike, M.; Machida, T.; Takegawa, N.; Kawakami, S.; Shirai, T.; Ogawa, T.

    2003-02-01

    The Biomass Burning and Lightning Experiment (BIBLE) A and B campaigns over the tropical western Pacific during springtime deployed a Gulfstream-II aircraft with systems to measure ozone and numerous precursor species. Aerosol measuring systems included a MASP optical particle counter, a condensation nucleus (CN) counter, and an absorption spectrometer for black carbon. Aerosol volume was very low in the middle and upper troposphere during both campaigns, and during BIBLE A, there was little aerosol enhancement in the boundary layer away from urban areas. In BIBLE B, there was marked aerosol enhancement in the lowest 3 km of the atmosphere. Mixing ratios of CN in cloud-free conditions in the upper troposphere were in general higher than in the boundary layer, indicating new particle formation from gaseous precursors. High concentrations of black carbon were observed during BIBLE B, with mass loadings up to 40 μg m-3 representing as much as one quarter of total aerosol mass. Strong correlations with hydrocarbon enhancement allow the determination of a black carbon emission ratio for the fires at that time. Expressed as elemental carbon, it is about 0.5% of carbon dioxide and 6% of carbon monoxide emissions from the same fires, comparable to methane production, and greater than that of other hydrocarbons.

  13. Black carbon in aerosol during BIBLE B

    NASA Astrophysics Data System (ADS)

    Liley, J. Ben; Baumgardner, D.; Kondo, Y.; Kita, K.; Blake, D. R.; Koike, M.; Machida, T.; Takegawa, N.; Kawakami, S.; Shirai, T.; Ogawa, T.

    2002-02-01

    The Biomass Burning and Lightning Experiment (BIBLE) A and B campaigns over the tropical western Pacific during springtime deployed a Gulfstream-II aircraft with systems to measure ozone and numerous precursor species. Aerosol measuring systems included a MASP optical particle counter, a condensation nucleus (CN) counter, and an absorption spectrometer for black carbon. Aerosol volume was very low in the middle and upper troposphere during both campaigns, and during BIBLE A, there was little aerosol enhancement in the boundary layer away from urban areas. In BIBLE B, there was marked aerosol enhancement in the lowest 3 km of the atmosphere. Mixing ratios of CN in cloud-free conditions in the upper troposphere were in general higher than in the boundary layer, indicating new particle formation from gaseous precursors. High concentrations of black carbon were observed during BIBLE B, with mass loadings up to 40 μg m-3 representing as much as one quarter of total aerosol mass. Strong correlations with hydrocarbon enhancement allow the determination of a black carbon emission ratio for the fires at that time. Expressed as elemental carbon, it is about 0.5% of carbon dioxide and 6% of carbon monoxide emissions from the same fires, comparable to methane production, and greater than that of other hydrocarbons.

  14. Measurements of the global distribution of carbon monoxide in the troposphere

    NASA Technical Reports Server (NTRS)

    Hinton, R. R.

    1982-01-01

    Carbon monoxide and methane grab samples were obtained simultaneously with ozone, aerosol, nitric oxide and DACOM CO measurements. Eighty grab samples were collected at various altitudes up to 19,000 ft. along a north-south flight path from Wallops Flight Center, VA to 11 N. CO and CH were analyzed by flame ionization gas chromatography with cryogenic preconcentration. The relationship between CO and O3 concentrated is examined. A comparative analysis between trends in aerosol and CO concentration is performed.

  15. 29 CFR 1917.24 - Carbon monoxide.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 29 Labor 7 2010-07-01 2010-07-01 false Carbon monoxide. 1917.24 Section 1917.24 Labor Regulations...) MARINE TERMINALS Marine Terminal Operations § 1917.24 Carbon monoxide. (a) Exposure limits. The carbon... employees shall be removed from the enclosed space if the carbon monoxide concentration exceeds a ceiling of...

  16. 21 CFR 862.3220 - Carbon monoxide test system.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Carbon monoxide test system. 862.3220 Section 862....3220 Carbon monoxide test system. (a) Identification. A carbon monoxide test system is a device intended to measure carbon monoxide or carboxyhemoglobin (carbon monoxide bound to the hemoglobin in the...

  17. Observation of carbonaceous aerosols and carbon monoxide in Mid-Atlantic region: Seasonal and inter-annual variations

    NASA Astrophysics Data System (ADS)

    Chen, L. A.; Doddridge, B. G.; Doddridge, B. G.; Dickerson, R. R.; Dickerson, R. R.

    2001-05-01

    As part of Maryland Aerosol Research and Characterization (MARCH-Atlantic) study, a long-term monitoring of ambient elemental and organic carbon (EC and OC) aerosols has been made at Fort Meade, MD (39.16° N 76.51° W; elevation 46 m MSL), a suburban site within the Baltimore-Washington (B-W) corridor, since July 1999. 24-hr average EC and OC are measured every day during the season-representative months (July 1999, October 1999, January 2000, April 2000 and July 2000). Carbon monoxide (CO) was also measured nearly continuously over the period. Strong correlation between EC and CO (r = 0.7 ~ 0.9) in every month suggests common or proximate sources, likely traffic emissions. The EC versus CO slope, however, varies in different seasons and is found to increase nonlinearly with the ambient temperature. EC source strength may peak in summer. OC shows strong correlation with EC (r ~ 0.95) only in winter, suggesting that OC is also of the same primary sources during wintertime. The Interagency Monitoring of Protected Visual Environments (IMPROVE) network has been measuring EC and OC around the United States since 1988. The FME data during July 1999 are also compared with simultaneous measurements at nearby IMPROVE sites, showing B-W corridor could be a major contributor to the carbonaceous aerosols in the Mid-Atlantic region. A decreasing trend of EC level is found in three IMPROVE sites in this region. This actually agrees with the decreasing trend of CO observed previously at Big Meadow, Shenandoah National Park if CO and EC are both influenced by traffic emissions.

  18. 29 CFR 1917.24 - Carbon monoxide.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 29 Labor 7 2011-07-01 2011-07-01 false Carbon monoxide. 1917.24 Section 1917.24 Labor Regulations Relating to Labor (Continued) OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR (CONTINUED) MARINE TERMINALS Marine Terminal Operations § 1917.24 Carbon monoxide. (a) Exposure limits. The carbon monoxide content of the atmosphere in...

  19. 29 CFR 1917.24 - Carbon monoxide.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 29 Labor 7 2012-07-01 2012-07-01 false Carbon monoxide. 1917.24 Section 1917.24 Labor Regulations Relating to Labor (Continued) OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR (CONTINUED) MARINE TERMINALS Marine Terminal Operations § 1917.24 Carbon monoxide. (a) Exposure limits. The carbon monoxide content of the atmosphere in...

  20. 29 CFR 1917.24 - Carbon monoxide.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 29 Labor 7 2013-07-01 2013-07-01 false Carbon monoxide. 1917.24 Section 1917.24 Labor Regulations Relating to Labor (Continued) OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR (CONTINUED) MARINE TERMINALS Marine Terminal Operations § 1917.24 Carbon monoxide. (a) Exposure limits. The carbon monoxide content of the atmosphere in...

  1. Probing into the aging dynamics of biomass burning aerosol by using satellite measurements of aerosol optical depth and carbon monoxide

    NASA Astrophysics Data System (ADS)

    Konovalov, Igor B.; Beekmann, Matthias; Berezin, Evgeny V.; Formenti, Paola; Andreae, Meinrat O.

    2017-04-01

    Carbonaceous aerosol released into the atmosphere from open biomass burning (BB) is known to undergo considerable chemical and physical transformations (aging). However, there is substantial controversy about the nature and observable effects of these transformations. A shortage of consistent observational evidence on BB aerosol aging processes under different environmental conditions and at various temporal scales hinders development of their adequate representations in chemistry transport models (CTMs). In this study, we obtain insights into the BB aerosol dynamics by using available satellite measurements of aerosol optical depth (AOD) and carbon monoxide (CO). The basic concept of our method is to consider AOD as a function of the BB aerosol photochemical age (that is, the time period characterizing the exposure of BB aerosol emissions to atmospheric oxidation reactions) predicted by means of model tracers. We evaluate the AOD enhancement ratio (ER) defined as the ratio of optical depth of actual BB aerosol with respect to that of a modeled aerosol tracer that is assumed to originate from the same fires as the real BB aerosol but that is not affected by any aging processes. To limit possible effects of model transport errors, the AOD measurements are normalized to CO column amounts that are also retrieved from satellite measurements. The method is applied to the analysis of the meso- and synoptic-scale evolution of aerosol in smoke plumes from major wildfires that occurred in Siberia in summer 2012. AOD and CO retrievals from MODIS and IASI measurements, respectively, are used in combination with simulations performed with the CHIMERE CTM. The analysis indicates that aging processes strongly affected the evolution of BB aerosol in the situation considered, especially in dense plumes (with spatial average PM2. 5 concentration exceeding 100 µg m-3). For such plumes, the ER is found to increase almost 2-fold on the scale of ˜ 10 h of daytime aerosol

  2. 40 CFR 52.2353 - Control strategy: Carbon monoxide.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 4 2010-07-01 2010-07-01 false Control strategy: Carbon monoxide. 52...: Carbon monoxide. Determination. EPA has determined that the Provo carbon monoxide “moderate” nonattainment area attained the carbon monoxide national ambient air quality standard by December 31, 1995. This...

  3. 40 CFR 52.1237 - Control strategy: Carbon monoxide.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 4 2010-07-01 2010-07-01 false Control strategy: Carbon monoxide. 52... strategy: Carbon monoxide. (a) The base year carbon monoxide emission inventory requirement of section 187... Metropolitan Area and Minneapolis-St. Paul Metropolitan Area. (b) Approval—The 1993 carbon monoxide periodic...

  4. The CAMS interim Reanalysis of Carbon Monoxide, Ozone and Aerosol for 2003-2015

    NASA Astrophysics Data System (ADS)

    Flemming, Johannes; Benedetti, Angela; Inness, Antje; Engelen, Richard J.; Jones, Luke; Huijnen, Vincent; Remy, Samuel; Parrington, Mark; Suttie, Martin; Bozzo, Alessio; Peuch, Vincent-Henri; Akritidis, Dimitris; Katragkou, Eleni

    2017-02-01

    A new global reanalysis data set of atmospheric composition (AC) for the period 2003-2015 has been produced by the Copernicus Atmosphere Monitoring Service (CAMS). Satellite observations of total column (TC) carbon monoxide (CO) and aerosol optical depth (AOD), as well as several TC and profile observations of ozone, have been assimilated with the Integrated Forecasting System for Composition (C-IFS) of the European Centre for Medium-Range Weather Forecasting. Compared to the previous Monitoring Atmospheric Composition and Climate (MACC) reanalysis (MACCRA), the new CAMS interim reanalysis (CAMSiRA) is of a coarser horizontal resolution of about 110 km, compared to 80 km, but covers a longer period with the intent to be continued to present day. This paper compares CAMSiRA with MACCRA and a control run experiment (CR) without assimilation of AC retrievals. CAMSiRA has smaller biases than the CR with respect to independent observations of CO, AOD and stratospheric ozone. However, ozone at the surface could not be improved by the assimilation because of the strong impact of surface processes such as dry deposition and titration with nitrogen monoxide (NO), which were both unchanged by the assimilation. The assimilation of AOD led to a global reduction of sea salt and desert dust as well as an exaggerated increase in sulfate. Compared to MACCRA, CAMSiRA had smaller biases for AOD, surface CO and TC ozone as well as for upper stratospheric and tropospheric ozone. Finally, the temporal consistency of CAMSiRA was better than the one of MACCRA. This was achieved by using a revised emission data set as well as by applying careful selection and bias correction to the assimilated retrievals. CAMSiRA is therefore better suited than MACCRA for the study of interannual variability, as demonstrated for trends in surface CO.

  5. An unusual case of carbon monoxide poisoning.

    PubMed Central

    Auger, P L; Levesque, B; Martel, R; Prud'homme, H; Bellemare, D; Barbeau, C; Lachance, P; Rhainds, M

    1999-01-01

    Carbon monoxide, a gas originating from incomplete combustion of carbon-based fuels, is an important cause of human deaths. In this paper, we describe an unusual carbon monoxide poisoning in a dwelling without obvious sources of combustion gases, for which two adults had to be treated in a hyperbaric chamber. Carbon monoxide readings were taken in the house and in the neighboring homes. Methane gas and nitrogen oxide levels were also monitored in the house air. Soil samples were collected around the house and tested for hydrocarbon residues. The investigation revealed the presence of a pocket of carbon monoxide under the foundation of the house. The first readings revealed carbon monoxide levels of 500 ppm in the basement. The contamination lasted for a week. The investigation indicated that the probable source of contamination was the use of explosives at a nearby rain sewer construction site. The use of explosives in a residential area can constitute a major source of carbon monoxide for the neighboring populations. This must be investigated, and public health authorities, primary-care physicians, governmental authorities, and users and manufacturers of explosives must be made aware of this problem. Images Figure 1 Figure 2 PMID:10379009

  6. 40 CFR 52.1887 - Control strategy: Carbon monoxide.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 4 2010-07-01 2010-07-01 false Control strategy: Carbon monoxide. 52...: Carbon monoxide. (a) Part D—Approval—The following portions of the Ohio plan are approved: (1) The carbon...) The carbon monoxide attainment and reasonable further progress demonstrations for the following urban...

  7. Device for staged carbon monoxide oxidation

    DOEpatents

    Vanderborgh, Nicholas E.; Nguyen, Trung V.; Guante, Jr., Joseph

    1993-01-01

    A method and apparatus for selectively oxidizing carbon monoxide in a hydrogen rich feed stream. The method comprises mixing a feed stream consisting essentially of hydrogen, carbon dioxide, water and carbon monoxide with a first predetermined quantity of oxygen (air). The temperature of the mixed feed/oxygen stream is adjusted in a first the heat exchanger assembly (20) to a first temperature. The mixed feed/oxygen stream is sent to reaction chambers (30,32) having an oxidation catalyst contained therein. The carbon monoxide of the feed stream preferentially absorbs on the catalyst at the first temperature to react with the oxygen in the chambers (30,32) with minimal simultaneous reaction of the hydrogen to form an intermediate hydrogen rich process stream having a lower carbon monoxide content than the feed stream. The elevated outlet temperature of the process stream is carefully controlled in a second heat exchanger assembly (42) to a second temperature above the first temperature. The process stream is then mixed with a second predetermined quantity of oxygen (air). The carbon monoxide of the process stream preferentially reacts with the second quantity of oxygen in a second stage reaction chamber (56) with minimal simultaneous reaction of the hydrogen in the process stream. The reaction produces a hydrogen rich product stream having a lower carbon monoxide content than the process stream. The product stream is then cooled in a third heat exchanger assembly (72) to a third predetermined temperature. Three or more stages may be desirable, each with metered oxygen injection.

  8. 40 CFR 52.349 - Control strategy: Carbon monoxide.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 3 2010-07-01 2010-07-01 false Control strategy: Carbon monoxide. 52... (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS Colorado § 52.349 Control strategy: Carbon monoxide. (a) Revisions to the Colorado State Implementation Plan, Carbon Monoxide Redesignation Request...

  9. 40 CFR 52.1528 - Control strategy: Carbon monoxide.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 4 2010-07-01 2010-07-01 false Control strategy: Carbon monoxide. 52... strategy: Carbon monoxide. (a) Approval—On February 1, 1999, the New Hampshire Department of Environmental... program for carbon monoxide that ceased operating on January 1, 1995. The Nashua Inspection/Maintenance...

  10. 40 CFR 52.1132 - Control strategy: Carbon Monoxide.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 4 2010-07-01 2010-07-01 false Control strategy: Carbon Monoxide. 52... strategy: Carbon Monoxide. (a) Approval—On November 13, 1992, the Massachusetts Department of Environmental Protection submitted a revision to the carbon monoxide State Implementation Plan for the 1990 base year...

  11. 40 CFR 52.1373 - Control strategy: Carbon monoxide.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 4 2010-07-01 2010-07-01 false Control strategy: Carbon monoxide. 52...: Carbon monoxide. (a) On July 8, 1997, the Governor of Montana submitted revisions to the SIP narrative for the Missoula carbon monoxide control plan. (b) Revisions to the Montana State Implementation Plan...

  12. 40 CFR 52.1185 - Control strategy: Carbon monoxide.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 4 2010-07-01 2010-07-01 false Control strategy: Carbon monoxide. 52...: Carbon monoxide. (a) Approval—On November 24, 1994, the Michigan Department of Natural Resources submitted a revision to the carbon monoxide State Implementation Plan. The submittal pertained to a plan for...

  13. 21 CFR 177.1312 - Ethylene-carbon monoxide copolymers.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 3 2010-04-01 2009-04-01 true Ethylene-carbon monoxide copolymers. 177.1312... Basic Components of Single and Repeated Use Food Contact Surfaces § 177.1312 Ethylene-carbon monoxide copolymers. The ethylene-carbon monoxide copolymers identified in paragraph (a) of this section may be safely...

  14. 40 CFR 60.263 - Standard for carbon monoxide.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 6 2010-07-01 2010-07-01 false Standard for carbon monoxide. 60.263... Production Facilities § 60.263 Standard for carbon monoxide. (a) On and after the date on which the... furnace any gases which contain, on a dry basis, 20 or greater volume percent of carbon monoxide...

  15. 40 CFR 60.263 - Standard for carbon monoxide.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 6 2011-07-01 2011-07-01 false Standard for carbon monoxide. 60.263... Production Facilities § 60.263 Standard for carbon monoxide. (a) On and after the date on which the... furnace any gases which contain, on a dry basis, 20 or greater volume percent of carbon monoxide...

  16. Method of removing carbon monoxide from gases

    DOEpatents

    Gerstein, Bernard C.; Macaulay, David B.

    1976-06-01

    A process and catalyst are disclosed for purifying an atmosphere containing carbon monoxide by passing the atmosphere through a bed of a catalyst of TbO.sub.x, where x = 1.8 to 1.5, which oxidizes the carbon monoxide to carbon dioxide.

  17. 21 CFR 868.1430 - Carbon monoxide gas analyzer.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Carbon monoxide gas analyzer. 868.1430 Section 868.1430 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Diagnostic Devices § 868.1430 Carbon monoxide gas analyzer. (a) Identification. A carbon monoxide gas...

  18. Carbon Monoxide Safety

    MedlinePlus

    ... portable generators? Source: National Institute of Standards and Technology More information on carbon monoxide safety Heating fire safety NFPA Educational Messages Desk Reference – these messages provide fire and ...

  19. Method and apparatus for selective removal of carbon monoxide

    DOEpatents

    Borup, Rodney L.; Skala, Glenn W.; Brundage, Mark A.; LaBarge, William J.

    2000-01-01

    There is provided a method and apparatus for treatment of a hydrogen-rich gas to reduce the carbon monoxide content thereof by reacting the carbon monoxide in the gas with an amount of oxygen sufficient to oxidize at least a portion of the carbon monoxide in the presence of a catalyst in a desired temperature range without substantial reaction of hydrogen. The catalyst is an iridium-based catalyst dispersed on, and supported on, a carrier. In the presence of the catalyst, carbon monoxide in a hydrogen-rich feed gas is selectively oxidized such that a product stream is produced with a very low carbon monoxide content.

  20. Carbon monoxide and the burning earth

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Newell, R.E.; Reichle, H.G. Jr.; Seiler, W.

    1989-10-01

    Carbon monoxide is one of many gases whose presence in the atmosphere is blamed largely on industrial activity in the Northern Hemisphere. Data collected by the authors show that the gas is also abundant in the Southern Hemisphere, where it comes mainly from the burning of tropical rain forests and savannas. The high levels of carbon monoxide confirm other evidence that the rain forests are being diminished rapidly, which may affect the climates of these regions as well as globally. Increases in carbon monoxide could also encourage the accumulation of pollutant gases such as ozone and methane. The first ismore » highly toxic to plants and the second would add to the greenhouse effect.« less

  1. Remote Sensing of Global Fire Patterns, Aerosol Optical Thickness, and Carbon Monoxide During April 1994

    NASA Technical Reports Server (NTRS)

    Christopher, Sundar A.; Wang, Min; Klich, Donna V.; Welch, Ronald M.; Nolf, Scott; Connors, Vickie S.

    1997-01-01

    Fires play a crucial role in several ecosystems. They are routinely used to burn forests in order to accommodate the needs of the expanding population, clear land for agricultural purposes, eliminate weeds and pests, regenerate nutrients in grazing and crop lands and produce energy for cooking and heating purposes. Most of the fires on earth are related to biomass burning in the tropics, although they are not confined to these latitudes. The boreal and tundra regions also experience fires on a yearly basis. The current study examines global fire patterns, Aerosol Optical Thickness (AOT) and carbon monoxide concentrations during April 9-19, 1994. Recently, global Advanced Very High Resolution Radiometer (AVHRR) data at nadir ground spatial resolution of 1 km are made available through the NASA/NOAA Pathfinder project. These data from April 9-19, 1994 are used to map fires over the earth. In summary, our analysis shows that fires from biomass burning appear to be the dominant factor for increased tropospheric CO concentrations as measured by the MAPS. The vertical transport of CO by convective activities, along with horizontal transport due to the prevailing winds, are responsible for the observed spatial distribution of CO.

  2. Carbon monoxide and lethal arrhythmias

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Farber, J.P.; Schwartz, P.J.; Vanoli, E.

    1990-12-01

    The effect of acute exposure to carbon monoxide on ventricular arrhythmias was studied in a previously described chronically maintained animal model of sudden cardiac death. In 60 percent of dogs with a healed anterior myocardial infarction, the combination of mild exercise and acute myocardial ischemia induces ventricular fibrillation. The events in this model are highly reproducible, thus allowing study by internal control analysis. Dogs that develop ventricular fibrillation during the test of exercise and acute myocardial ischemia are considered at high risk for sudden death and are defined as 'susceptible'; dogs that survive the test without a fatal arrhythmia aremore » considered at low risk for sudden death and are defined as 'resistant.' In the current study, the effects of carboxyhemoglobin levels ranging from 5 to 15 percent were tested in resistant and susceptible dogs. A trend toward higher heart rates was observed at all levels of carboxyhemoglobin, although significant differences were observed only with 15 percent carboxyhemoglobin. This trend was observed at rest and during exercise in both resistant and susceptible dogs. In resistant animals, in which acute myocardial ischemia is typically associated with bradycardia even under the control condition, this reflex response occurred earlier and was augmented after exposure to carbon monoxide. This effect may depend on the increased hypoxic challenge caused by carbon monoxide, and thus on an augmentation of the neural reflex activation or a sensitization of the sinus node to acetylcholine induced by hypoxia. In both resistant and susceptible dogs, carbon monoxide exposure induced a worsening of ventricular arrhythmias in a minority of cases. This worsening was not reproducible in subsequent trials. These data indicate that acute exposure to carbon monoxide is seldom arrhythmogenic in dogs that have survived myocardial infarction. (Abstract Truncated)« less

  3. POLICY ASSESSMENT FOR THE CARBON MONOXIDE ...

    EPA Pesticide Factsheets

    As part of the NAAQS review process, a Risk/Exposure Assessment (REA) has been developed by OAQPS and has receieved inital review by the Clean Air Scientific Advisory Committee (CASAC). A second review of the REA will be conducted in March 2010. The Policy Assessment for the Carbon monoxide NAAQS Review is being developed and will include summaries of the findings of recent key scientific studies reviewed in the Integrated Science Assessment (ISA), will draw conclusions as to the adequacy of the existing carbon monoxide NAAQS for protection of public health, and will make recommendations regarding revision or reaffirmation of the carbon monoxide NAAQS. This work will be reviewed by the CASAC in March 2010. CASAC provides independent advice to the EPA Administrator on the technical bases for EPA's NAAQS. Presents implications for any needed changes to the carbon monoxide NAAQS, including human health risks and human population exposure associated with the carbon monoxide NAAQS and potential alternative ambient standards. (This work will be reviewed by the Clean Air Scientific Advisory Committee (CASAC). CASAC provides independent advice to the EPA Administrator on the technical bases for EPA's national ambient air quality standards. Established in 1977 under the Clean Air Act (CAA) Amendments of 1977 (see 42 U.S.C. § 7409(d)(2)), CASAC also addresses research related to air quality, sources of air pollution, and the strategies to attain and maintain air quality

  4. Suicide from carbon monoxide poisoning in South Korea: 2006-2012.

    PubMed

    Choi, Young-Rim; Cha, Eun Shil; Chang, Shu-Sen; Khang, Young-Ho; Lee, Won Jin

    2014-01-01

    Suicide from carbon monoxide poisoning by burning coal briquette or barbecue charcoal increased rapidly in some East Asian countries in the recent decade. The purpose of this study was to examine trends in suicides from carbon monoxide poisoning in South Korea and their epidemiologic characteristics. We presented age-standardized mortality rates of carbon monoxide suicide and compared them with those of suicide by other methods using registered death data from Statistics Korea (South Korea) from 2006 to 2012. Logistic regression analysis was conducted to estimate odds ratios of carbon monoxide suicide by socio-demographic characteristics before and after the marked increase in carbon monoxide suicide in September 2008. The number of carbon monoxide suicides in South Korea was only 34 in 2006 but rapidly increased to 267 in 2008 and was 1125 in 2012, with the age-standardized rates of 0.06 (2006), 0.48 (2008), and 1.97 (2012) per 100,000 population respectively (a striking 3,183% increase in 2006-2012). Suicide by carbon monoxide poisoning showed greater odds ratios among men, younger age groups, single or the divorced, and those with high education and non-manual jobs compared with suicides by other methods. This study only used data for fatal self-poisoning by carbon monoxide (non-fatal cases not included) and had no information on the sources of carbon monoxide. Carbon monoxide suicides substantially increased in South Korea over the relatively short study period and showed some distinct socio-demographic characteristics compared with suicides by other methods. Copyright © 2014 Elsevier B.V. All rights reserved.

  5. 40 CFR 86.316-79 - Carbon monoxide and carbon dioxide analyzer specifications.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 18 2011-07-01 2011-07-01 false Carbon monoxide and carbon dioxide... AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) CONTROL OF EMISSIONS FROM NEW AND IN-USE HIGHWAY VEHICLES AND... Test Procedures § 86.316-79 Carbon monoxide and carbon dioxide analyzer specifications. (a) Carbon...

  6. 40 CFR 52.785 - Control strategy: Carbon monoxide.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 3 2010-07-01 2010-07-01 false Control strategy: Carbon monoxide. 52... (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS Indiana § 52.785 Control strategy: Carbon... for attainment and maintenance of the national standards for carbon monoxide in the Metropolitan...

  7. Gas geyser--a cause of fatal domestic carbon monoxide poisoning.

    PubMed

    Mohankumar, T S; Kanchan, Tanuj; Pinakini, K S; Menezes, Ritesh G; Singh, Manisha; Sirohi, Parmendra; Anwar, Naureen

    2012-11-01

    Carbon monoxide is responsible for a large number of accidental domestic poisoning and deaths throughout the world. Domestic carbon monoxide poisoning is rarely reported in India and remains an under recognized problem. The diagnosis of carbon monoxide poisoning is usually based on autopsy findings, circumstantial evidence and estimation of carboxy-haemoglobin in blood. We report a case of fatal accidental carbon monoxide poisoning in a bathroom where an LPG gas water heater was installed recently. Cherry pink discolouration of the body and organs on autopsy suggested carbon monoxide poisoning. Laboratory analysis of blood by UV visible spectrophotometry revealed presence of dangerous levels of carboxy-haemoglobin. Effective preventive measures can help in bringing down the mortality and morbidity associated with carbon monoxide poisoning. Copyright © 2012 Elsevier Ltd and Faculty of Forensic and Legal Medicine. All rights reserved.

  8. 40 CFR 52.376 - Control strategy: Carbon monoxide.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 3 2010-07-01 2010-07-01 false Control strategy: Carbon monoxide. 52... (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS Connecticut § 52.376 Control strategy: Carbon... submitted a revision to the carbon monoxide State Implementation Plan for the 1990 base year emission...

  9. 40 CFR 52.376 - Control strategy: Carbon monoxide.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 3 2013-07-01 2013-07-01 false Control strategy: Carbon monoxide. 52... (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS Connecticut § 52.376 Control strategy: Carbon... submitted a revision to the carbon monoxide State Implementation Plan for the 1990 base year emission...

  10. 40 CFR 52.376 - Control strategy: Carbon monoxide.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 3 2014-07-01 2014-07-01 false Control strategy: Carbon monoxide. 52... (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS Connecticut § 52.376 Control strategy: Carbon... submitted a revision to the carbon monoxide State Implementation Plan for the 1990 base year emission...

  11. 40 CFR 52.376 - Control strategy: Carbon monoxide.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 3 2011-07-01 2011-07-01 false Control strategy: Carbon monoxide. 52... (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS Connecticut § 52.376 Control strategy: Carbon... submitted a revision to the carbon monoxide State Implementation Plan for the 1990 base year emission...

  12. 40 CFR 52.376 - Control strategy: Carbon monoxide.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 3 2012-07-01 2012-07-01 false Control strategy: Carbon monoxide. 52... (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS Connecticut § 52.376 Control strategy: Carbon... submitted a revision to the carbon monoxide State Implementation Plan for the 1990 base year emission...

  13. 40 CFR 52.2089 - Control strategy: carbon monoxide.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 4 2010-07-01 2010-07-01 false Control strategy: carbon monoxide. 52... strategy: carbon monoxide. (a) Approval—On September 22, 2008, the Rhode Island Department of Environmental Management submitted a request to establish a limited maintenance plan for the Providence Rhode Island carbon...

  14. 40 CFR 52.1627 - Control strategy and regulations: Carbon monoxide.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...: Carbon monoxide. 52.1627 Section 52.1627 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... § 52.1627 Control strategy and regulations: Carbon monoxide. (a) Part D Approval. The Albuquerque/Bernalillo County carbon monoxide maintenance plan as adopted on April 13, 1995, meets the requirements of...

  15. Search of medical literature for indoor carbon monoxide exposure

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brennan, T.; Ivanovich, M.

    1995-12-01

    This report documents a literature search on carbon monoxide. The search was limited to the medical and toxicological databases at the National Library of Medicine (MEDLARS). The databases searched were Medline, Toxline and TOXNET. Searches were performed using a variety of strategies. Combinations of the following keywords were used: carbon, monoxide, accidental, residential, occult, diagnosis, misdiagnosis, heating, furnace, and indoor. The literature was searched from 1966 to the present. Over 1000 references were identified and summarized using the following abbreviations: The major findings of the search are: (1) Acute and subacute carbon monoxide exposures result in a large number ofmore » symptoms affecting the brain, kidneys, respiratory system, retina, and motor functions. (2) Acute and subacute carbon monoxide (CO) poisonings have been misdiagnosed on many occasions. (3) Very few systematic investigations have been made into the frequency and consequences of carbon monoxide poisonings.« less

  16. Engineering evidence for carbon monoxide toxicity cases.

    PubMed

    Galatsis, Kosmas

    2016-07-01

    Unintentional carbon monoxide poisonings and fatalities lead to many toxicity cases. Given the unusual physical properties of carbon monoxide-in that the gas is odorless and invisible-unorganized and erroneous methods in obtaining engineering evidence as required during the discovery process often occurs. Such evidence gathering spans domains that include building construction, appliance installation, industrial hygiene, mechanical engineering, combustion and physics. In this paper, we attempt to place a systematic framework that is relevant to key aspects in engineering evidence gathering for unintentional carbon monoxide poisoning cases. Such a framework aims to increase awareness of this process and relevant issues to help guide legal counsel and expert witnesses. © The Author(s) 2015.

  17. Carbon monoxide sensor and method of use thereof

    DOEpatents

    McDaniel; Anthony H. , Medlin; J. Will , Bastasz; Robert J.

    2007-09-04

    Carbon monoxide sensors suitable for use in hydrogen feed streams and methods of use thereof are disclosed. The sensors are palladium metal/insulator/semiconductor (Pd-MIS) sensors which may possess a gate metal layer having uniform, Type 1, or non-uniform, Type 2, film morphology. Type 1 sensors display an increased sensor response in the presence of carbon monoxide while Type 2 sensors display a decreased response to carbon monoxide. The methods and sensors disclosed herein are particularly suitable for use in proton exchange membrane fuel cells (PEMFCs).

  18. Estimating carbon monoxide exposure

    NASA Technical Reports Server (NTRS)

    Edgerley, R. H.

    1971-01-01

    Method predicts effects of carbon monoxide on astronauts confined in spacecraft cabin atmospheres. Information on need for low toxicity level also applies to confined spaces. Benefits are applicable to industry and public health.

  19. Mechanistical studies on the formation of carbon dioxide in extraterrestrial carbon monoxide ice analog samples.

    PubMed

    Bennett, Chris J; Jamieson, Corey S; Kaiser, Ralf I

    2009-06-07

    Binary ice mixtures of two carbon monoxide isotopomers, (13)C(16)O and (12)C(18)O, were subjected at 10 K to energetic electrons to investigate the interaction of ionizing radiation with extraterrestrial, carbon monoxide bearing ices. The chemical modifications were monitored on line and in situ via absorption-reflection-absorption Fourier transform infrared spectroscopy as well as in the gas-phase via a quadrupole mass spectrometer. Detected products include two newly formed carbon monoxide isotopomers ((12)C(16)O and (13)C(18)O), carbon dioxide ((12)C(16)O(2), (12)C(18)O(16)O, (12)C(18)O(2), (13)C(16)O(2), (13)C(18)O(16)O, and (13)C(18)O(2)), and dicarbon monoxide ((12)C(13)C(16)O and (13)C(13)C(16)O). Kinetic profiles of carbon monoxide and of carbon dioxide were extracted and fit to derive reaction mechanisms and information on the decomposition of carbon monoxide and on the formation of carbon dioxide in extraterrestrial ice analog samples.

  20. Estimating Effects of Brazilian Forest Wildfires on the Carbon Monoxide Concentration

    NASA Astrophysics Data System (ADS)

    Bhoi, S.; Qu, J.; Dasgupta, S.

    2004-12-01

    Forest wildfires have dramatically increased in recent years due to global warming and extreme dry conditions. Forest wildfires spew out a significant amount of atmospheric pollutants, such as carbon monoxide, due to incomplete burning of the biomass. According to United State Environmental Protection Agency (EPA), a high increase of carbon monoxide leads to the formation of carboxyhemoglobin in blood which decreases the oxygen intake capacity of human body and at moderate concentration angina, impaired vision and reduced brain function may occur. As compared to Northern America where significant amount of carbon monoxide released is caused by combustion devices and furnace, the increase of carbon monoxide concentration in Brazilian regions is mainly attributed to the forest fires. In this study, carbon monoxide datasets from the Measurements of pollution in the troposphere (MOPITT) have been analyzed to see the amount of increase in the carbon monoxide concentration after forest wildfires, ire, particularly in summer of 2003. The study reveals that there is a significant increase in the carbon monoxide concentration after forest fires.

  1. 40 CFR 52.1179 - Control strategy: Carbon monoxide.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 4 2010-07-01 2010-07-01 false Control strategy: Carbon monoxide. 52.1179 Section 52.1179 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS...: Carbon monoxide. (a) Approval—On March 18, 1999, the Michigan Department of Environmental Quality...

  2. 40 CFR 52.1340 - Control strategy: Carbon monoxide.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 4 2010-07-01 2010-07-01 false Control strategy: Carbon monoxide. 52.1340 Section 52.1340 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS...: Carbon monoxide. Approval—A maintenance plan and redesignation request for the St. Louis, Missouri, area...

  3. Modeling of exposure to carbon monoxide in fires

    NASA Technical Reports Server (NTRS)

    Cagliostro, D. E.

    1980-01-01

    A mathematical model is developed to predict carboxyhemoglobin concentrations in regions of the body for short exposures to carbon monoxide levels expected during escape from aircraft fires. The model includes the respiratory and circulatory dynamics of absorption and distribution of carbon monoxide and carboxyhemoglobin. Predictions of carboxyhemoglobin concentrations are compared to experimental values obtained for human exposures to constant high carbon monoxide levels. Predictions are within 20% of experimental values. For short exposure times, transient concentration effects are predicted. The effect of stress is studied and found to increase carboxyhemoglobin levels substantially compared to a rest state.

  4. Long-term measurements of aerosols and carbon monoxide at the ZOTTO tall tower to characterize polluted and pristine air in the Siberian Taiga

    NASA Astrophysics Data System (ADS)

    Chi, X.; Winderlich, J.; Mayer, J.-C.; Panov, A. V.; Heimann, M.; Birmili, W.; Heintzenberg, J.; Cheng, Y.; Andreae, M. O.

    2013-07-01

    Siberia is one of few background regions in the Northern Hemisphere where the atmosphere may sometimes approach pristine conditions. We present the time series of aerosol and carbon monoxide (CO) measurements between September~2006 and December 2010 at the Zotino Tall Tower Observatory (ZOTTO) in Central Siberia (61° N; 90° E). We investigate the seasonal, weekly and diurnal variations of aerosol properties (including absorption and scattering coefficients and derived parameters, like equivalent black carbon (BCe), Ångström exponent, single scattering albedo, and backscattering ratio) and the CO mixing ratios. Criteria were established to distinguish polluted and near-pristine air masses and characterize them separately. Depending on the season, 15-47% of the sampling time at ZOTTO was representative of a clean atmosphere. The summer pristine data indicates that primary biogenic and/or secondary organic aerosol formation are quite strong particle sources in the Siberian Taiga. The summer seasons 2007-2008 are dominated by an Aitken mode of 80 nm size, whereas the summer 2009 with prevailing easterly winds produced aerosols in the accumulation mode around 200 nm size. We found these differences mainly related to air temperature, in parallel with production rates of biogenic volatile organic compounds (VOC). In winter, the footprint and aerosol size distribution (with a peak at 160 nm) of the clean background air are characteristic for aged aerosols from anthropogenic sources at great distances from ZOTTO and diluted biofuel burning emissions from heating. The wintertime polluted air originates from the large cities to the south and southwest of the site; these aerosols have a dominant mode around 100 nm, and the Δ BCe/Δ CO ratio of 7-11 ng m-3 ppb-1 suggests dominant contributions from coal and biofuel burning for heating. During summer, anthropogenic emissions are the dominant contributor to the pollution aerosols at ZOTTO, while only 12% of the polluted

  5. 21 CFR 868.1430 - Carbon monoxide gas analyzer.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... techniques such as infrared absorption or gas chromatography. (b) Classification. Class II (performance... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Carbon monoxide gas analyzer. 868.1430 Section 868...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Diagnostic Devices § 868.1430 Carbon monoxide gas analyzer. (a...

  6. 21 CFR 868.1430 - Carbon monoxide gas analyzer.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... techniques such as infrared absorption or gas chromatography. (b) Classification. Class II (performance... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Carbon monoxide gas analyzer. 868.1430 Section 868...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Diagnostic Devices § 868.1430 Carbon monoxide gas analyzer. (a...

  7. 40 CFR 52.1132 - Control strategy: Carbon Monoxide.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 4 2013-07-01 2013-07-01 false Control strategy: Carbon Monoxide. 52.1132 Section 52.1132 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS (CONTINUED) Massachusetts § 52.1132 Control strategy: Carbon Monoxide. (a)...

  8. 40 CFR 52.1132 - Control strategy: Carbon Monoxide.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 4 2011-07-01 2011-07-01 false Control strategy: Carbon Monoxide. 52.1132 Section 52.1132 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS (CONTINUED) Massachusetts § 52.1132 Control strategy: Carbon Monoxide. (a)...

  9. 40 CFR 52.1132 - Control strategy: Carbon Monoxide.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 4 2014-07-01 2014-07-01 false Control strategy: Carbon Monoxide. 52.1132 Section 52.1132 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS (CONTINUED) Massachusetts § 52.1132 Control strategy: Carbon Monoxide. (a)...

  10. Carbon Monoxide Oxidation by Clostridium thermoaceticum and Clostridium formicoaceticum

    PubMed Central

    Diekert, Gabriele B.; Thauer, Rudolf K.

    1978-01-01

    Cultures of Clostridium formicoaceticum and C. thermoaceticum growing on fructose and glucose, respectively, were shown to rapidly oxidize CO to CO2. Rates up to 0.4 μmol min−1 mg of wet cells−1 were observed. Carbon monoxide oxidation by cell suspensions was found (i) to be dependent on pyruvate, (ii) to be inhibited by alkyl halides and arsenate, and (iii) to stimulate CO2 reduction to acetate. Cell extracts catalyzed the oxidation of carbon monoxide with methyl viologen at specific rates up to 10 μmol min−1 mg of protein−1 (35°C, pH 7.2). Nicotinamide adenine dinucleotide, nicotinamide adenine dinucleotide phosphate and ferredoxin from C. pasteurianum were ineffective as electron acceptors. The catalytic mechanism of carbon monoxide oxidation was “ping-pong,” indicating that the enzyme catalyzing carbon monoxide oxidation can be present in an oxidized and a reduced form. The oxidized form was shown to react reversibly with cyanide, and the reduced form was shown to react reversibly with alkyl halides: cyanide inactivated the enzyme only in the absence of carbon monoxide, and alkyl halides inactivated it only in the presence of carbon monoxide. Extracts inactivated by alkyl halides were reactivated by photolysis. The findings are interpreted to indicate that carbon monoxide oxidation in the two bacteria is catalyzed by a corrinoid enzyme and that in vivo the reaction is coupled with the reduction of CO2 to acetate. Cultures of C. acidi-urici and C. cylindrosporum growing on hypoxanthine were found not to oxidize CO, indicating that clostridia mediating a corrinoid-independent total synthesis of acetate from CO2 do not possess a CO-oxidizing system. PMID:711675

  11. 40 CFR 52.1340 - Control strategy: Carbon monoxide.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 4 2013-07-01 2013-07-01 false Control strategy: Carbon monoxide. 52.1340 Section 52.1340 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS (CONTINUED) Missouri § 52.1340 Control strategy: Carbon monoxide. Approval—A...

  12. 40 CFR 52.1179 - Control strategy: Carbon monoxide.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 4 2014-07-01 2014-07-01 false Control strategy: Carbon monoxide. 52.1179 Section 52.1179 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS (CONTINUED) Michigan § 52.1179 Control strategy: Carbon monoxide. (a) Approval—On...

  13. 40 CFR 52.2353 - Control strategy: Carbon monoxide.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 5 2014-07-01 2014-07-01 false Control strategy: Carbon monoxide. 52.2353 Section 52.2353 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS (CONTINUED) Utah § 52.2353 Control strategy: Carbon monoxide. Determination. EPA has...

  14. 40 CFR 52.729 - Control strategy: Carbon monoxide.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 3 2013-07-01 2013-07-01 false Control strategy: Carbon monoxide. 52.729 Section 52.729 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS Illinois> § 52.729 Control strategy: Carbon monoxide. The following source specific...

  15. 40 CFR 52.1528 - Control strategy: Carbon monoxide.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 4 2014-07-01 2014-07-01 false Control strategy: Carbon monoxide. 52.1528 Section 52.1528 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS (CONTINUED) New Hampshire § 52.1528 Control strategy: Carbon monoxide. (a)...

  16. 40 CFR 52.2353 - Control strategy: Carbon monoxide.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 5 2013-07-01 2013-07-01 false Control strategy: Carbon monoxide. 52.2353 Section 52.2353 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS (CONTINUED) Utah § 52.2353 Control strategy: Carbon monoxide. Determination. EPA has...

  17. 40 CFR 52.729 - Control strategy: Carbon monoxide.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 3 2014-07-01 2014-07-01 false Control strategy: Carbon monoxide. 52.729 Section 52.729 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS Illinois> § 52.729 Control strategy: Carbon monoxide. The following source specific...

  18. 40 CFR 52.1179 - Control strategy: Carbon monoxide.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 4 2013-07-01 2013-07-01 false Control strategy: Carbon monoxide. 52.1179 Section 52.1179 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS (CONTINUED) Michigan § 52.1179 Control strategy: Carbon monoxide. (a) Approval—On...

  19. 40 CFR 52.1528 - Control strategy: Carbon monoxide.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 4 2013-07-01 2013-07-01 false Control strategy: Carbon monoxide. 52.1528 Section 52.1528 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS (CONTINUED) New Hampshire § 52.1528 Control strategy: Carbon monoxide. (a)...

  20. 40 CFR 52.729 - Control strategy: Carbon monoxide.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 3 2012-07-01 2012-07-01 false Control strategy: Carbon monoxide. 52.729 Section 52.729 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS Illinois> § 52.729 Control strategy: Carbon monoxide. The following source specific...

  1. 40 CFR 52.1185 - Control strategy: Carbon monoxide.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 4 2013-07-01 2013-07-01 false Control strategy: Carbon monoxide. 52.1185 Section 52.1185 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS (CONTINUED) Michigan § 52.1185 Control strategy: Carbon monoxide. (a) Approval—On...

  2. 40 CFR 52.1340 - Control strategy: Carbon monoxide.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 4 2014-07-01 2014-07-01 false Control strategy: Carbon monoxide. 52.1340 Section 52.1340 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS (CONTINUED) Missouri § 52.1340 Control strategy: Carbon monoxide. Approval—A...

  3. 40 CFR 52.1185 - Control strategy: Carbon monoxide.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 4 2014-07-01 2014-07-01 false Control strategy: Carbon monoxide. 52.1185 Section 52.1185 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS (CONTINUED) Michigan § 52.1185 Control strategy: Carbon monoxide. (a) Approval—On...

  4. 40 CFR 52.1682 - Control strategy: Carbon monoxide.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 4 2014-07-01 2014-07-01 false Control strategy: Carbon monoxide. 52.1682 Section 52.1682 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS (CONTINUED) New York § 52.1682 Control strategy: Carbon monoxide. (a) Approval—The...

  5. 40 CFR 60.103 - Standard for carbon monoxide.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 7 2013-07-01 2013-07-01 false Standard for carbon monoxide. 60.103 Section 60.103 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Petroleum Refineries § 60.103 Standard for carbon monoxide....

  6. 40 CFR 52.1373 - Control strategy: Carbon monoxide.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 4 2014-07-01 2014-07-01 false Control strategy: Carbon monoxide. 52.1373 Section 52.1373 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS (CONTINUED) Montana § 52.1373 Control strategy: Carbon monoxide. (a) On July 8, 1997...

  7. 40 CFR 52.1682 - Control strategy: Carbon monoxide.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 4 2013-07-01 2013-07-01 false Control strategy: Carbon monoxide. 52.1682 Section 52.1682 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS (CONTINUED) New York § 52.1682 Control strategy: Carbon monoxide. (a) Approval—The...

  8. 40 CFR 60.103 - Standard for carbon monoxide.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 7 2012-07-01 2012-07-01 false Standard for carbon monoxide. 60.103 Section 60.103 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Petroleum Refineries § 60.103 Standard for carbon monoxide....

  9. 40 CFR 60.103 - Standard for carbon monoxide.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 7 2014-07-01 2014-07-01 false Standard for carbon monoxide. 60.103 Section 60.103 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Petroleum Refineries § 60.103 Standard for carbon monoxide....

  10. 40 CFR 52.1581 - Control strategy: Carbon monoxide.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 4 2014-07-01 2014-07-01 false Control strategy: Carbon monoxide. 52.1581 Section 52.1581 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS (CONTINUED) New Jersey § 52.1581 Control strategy: Carbon monoxide. (a) Approval—The...

  11. 40 CFR 52.1581 - Control strategy: Carbon monoxide.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 4 2013-07-01 2013-07-01 false Control strategy: Carbon monoxide. 52.1581 Section 52.1581 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS (CONTINUED) New Jersey § 52.1581 Control strategy: Carbon monoxide. (a) Approval—The...

  12. 40 CFR 52.785 - Control strategy: Carbon monoxide.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 3 2014-07-01 2014-07-01 false Control strategy: Carbon monoxide. 52.785 Section 52.785 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS Indiana § 52.785 Control strategy: Carbon monoxide. (a) The requirements of subpart G...

  13. 40 CFR 52.2089 - Control strategy: carbon monoxide.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 5 2013-07-01 2013-07-01 false Control strategy: carbon monoxide. 52.2089 Section 52.2089 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS (CONTINUED) Rhode Island § 52.2089 Control strategy: carbon monoxide. (a) Approval—O...

  14. 40 CFR 52.785 - Control strategy: Carbon monoxide.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 3 2013-07-01 2013-07-01 false Control strategy: Carbon monoxide. 52.785 Section 52.785 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS Indiana § 52.785 Control strategy: Carbon monoxide. (a) The requirements of subpart G...

  15. 40 CFR 52.2089 - Control strategy: carbon monoxide.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 5 2014-07-01 2014-07-01 false Control strategy: carbon monoxide. 52.2089 Section 52.2089 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS (CONTINUED) Rhode Island § 52.2089 Control strategy: carbon monoxide. (a) Approval—O...

  16. 40 CFR 52.1373 - Control strategy: Carbon monoxide.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 4 2013-07-01 2013-07-01 false Control strategy: Carbon monoxide. 52.1373 Section 52.1373 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS (CONTINUED) Montana § 52.1373 Control strategy: Carbon monoxide. (a) On July 8, 1997...

  17. 40 CFR 52.785 - Control strategy: Carbon monoxide.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 3 2012-07-01 2012-07-01 false Control strategy: Carbon monoxide. 52.785 Section 52.785 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS Indiana § 52.785 Control strategy: Carbon monoxide. (a) The requirements of subpart G...

  18. CPSC Warns of Carbon Monoxide Poisoning with Camping Equipment

    MedlinePlus

    ... Warns of Carbon Monoxide Poisoning Hazard with Camping Equipment The U.S. Consumer Product Safety Commission (CPSC) warns ... about the carbon monoxide (CO) hazard with camping equipment. CO can kill you! From 2002–2006, CPSC ...

  19. [Delayed neurological syndrome following carbon monoxide poisoning].

    PubMed

    Vázquez-Lima, Manuel J; Álvarez-Rodríguez, Cesáreo; Cruz-Landeira, Angelines; López-Rivadulla, Manuel

    2015-08-16

    Poisoning by carbon monoxide is the most frequent form of intoxication in our milieu as a result of exposure to poisonous gases. The effects of carbon monoxide poisoning are not limited to acute exposure, since, following apparent recovery from the acute intoxication, neurological or behavioural disorders may appear. A study was conducted to examine the cases of carbon monoxide poisoning that had occurred in a healthcare area of 80,000 inhabitants over a 10-year period. These patients were then submitted to a follow-up to appraise the appearance of delayed neurological syndrome (DNS) and its relationship with different variables in the initial exposure to the carbon monoxide, in the treatment that was administered or in the severity of the intoxication. It was observed that around 9.1% of those intoxicated by carbon dioxide detected within the healthcare district of Salnés went on to develop DNS, which is more frequent in patients with severe analytical criteria and very unlikely in those who do not have them. Patients with DNS did not express any clinical or analytical manifestations that differed from those who did not have the syndrome; no differences were observed in relation to the oxygen therapy that was administered. The rate of DNS within the healthcare district of Salnés between 2002 and 2012 is 0.84 cases per 100,000 inhabitants per year.

  20. Mobile Carbon Monoxide Monitoring System Based on Arduino-Matlab for Environmental Monitoring Application

    NASA Astrophysics Data System (ADS)

    Azieda Mohd Bakri, Nur; Junid, Syed Abdul Mutalib Al; Razak, Abdul Hadi Abdul; Idros, Mohd Faizul Md; Karimi Halim, Abdul

    2015-11-01

    Nowadays, the increasing level of carbon monoxide globally has become a serious environmental issue which has been highlighted in most of the country globally. The monitoring of carbon monoxide content is one of the approaches to identify the level of carbon monoxide pollution towards providing the solution for control the level of carbon monoxide produced. Thus, this paper proposed a mobile carbon monoxide monitoring system for measuring the carbon monoxide content based on Arduino-Matlab General User Interface (GUI). The objective of this project is to design, develop and implement the real-time mobile carbon monoxide sensor system and interfacing for measuring the level of carbon monoxide contamination in real environment. Four phases or stages of work have been carried out for the accomplishment of the project, which classified as sensor development, controlling and integrating sensor, data collection and data analysis. As a result, a complete design and developed system has been verified with the handheld industrial standard carbon monoxide sensor for calibrating the sensor sensitivity and measurement in the laboratory. Moreover, the system has been tested in real environments by measuring the level of carbon monoxide in three different lands used location; industrial area; residential area and main road (commercial area). In this real environment test, the industrial area recorded the highest reading with 71.23 ppm and 82.59 ppm for sensor 1 and sensor 2 respectively. As a conclusion, the mobile realtime carbon monoxide system based on the Arduino-Matlab is the best approach to measure the carbon monoxide concentration in different land-used since it does not require a manual data collection and reduce the complexity of the existing carbon monoxide level concentration measurement practise at the same time with a complete data analysis facilities.

  1. Carbon monoxide: from the origin of life to molecular medicine.

    PubMed

    Bach, Fritz H

    2006-08-01

    Carbon monoxide, long considered only as a toxic gas, has recently been shown to mediate potent anti-inflammatory and other salutary effects in rodents when it is used at low doses. Carbon monoxide is one of the products of the degradation of heme by heme oxygenase 1. Until recently, these beneficial effects of carbon monoxide were shown only when it was given before a stress stimulus. Hagazi and colleagues have recently shown that this substance is effective even when it is given after a disease process has started. The effects of low doses of carbon monoxide are complemented by the production of biliverdin and probably also by ferritin, which are additional products of heme degradation.

  2. Continuous Thermometric Apparatus for Carbon Monoxide Detection

    DTIC Science & Technology

    1943-08-30

    small cell containing Hopcalite , and a stream of air(1.5 li- ters per minute) passes; through the catalyst and around the ther- mometer bulb. The...from the heat of oxidation on the Hopcalite of selected concentrations of carbon monoxide. Thus in one thermometer used the base temperature was...in air. The air was drawn through a small quantity of Hopcalite , on which the carbon monoxide was oxidized, and the rise in temperature resulting

  3. [Exposure to carbon monoxide in wildland firefighters during wildfires suppression].

    PubMed

    Carballo Leyenda, Belén; Rodríguez-Marroyo, José A; López-Satué, Jorge; Avila Ordás, Concepción; Pernía Cubillo, Raúl; Villa Vicente, José Gerardo

    2010-01-01

    Health and occupational performance in wildland firefighters are mainly impaired for the carbon monoxide inhalation. Therefore, the aim of this study was to analyze the personal exposure to carbon monoxide in wildland firefighters during wildfires suppression. Carbon monoxide exposure was monitorized in 44 subjects during 58 real wildfires. Moreover, we analyzed the time weighted average exposure for an 8h shift (VA-ED). The wildfires were classified according to the work done (direct attack, indirect attack and mixed attack) and the current fuel (grass, bush, understory and mixed). The mean exposure to carbon monoxide was of 18,4 ± 1,7 ppm, what supposed a VA-ED of 7,0 ± 1,0 ppm. The highest exposures to carbon monoxide were found during the mixed attack (20,4 ± 2,3 ppm) and direct attack (17,5 ± 2,7 ppm). We only obtained significant differences (p < 0.05) between bush (19,8 ± 2,2) and understory (17,2 ± 3,9) and grass (12,0 ± 5,6). Exposures to carbon monoxide were influenced for the work done during the wildfires suppression and the type of fuel involved. Mean values obtained in this study were within safety limits described by different Spanish (INSHT) and international (NIOSH, OSHA) occupational safety and health agencies.

  4. An interesting cause of pulmonary emboli: Acute carbon monoxide poisoning

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sevinc, A.; Savli, H.; Atmaca, H.

    Carbon monoxide poisoning, a public health problem of considerable significance, is a relatively frequent event today, resulting in thousands of hospitalizations annually. A 70-year-old lady was seen in the emergency department with a provisional diagnosis of carbon monoxide poisoning. The previous night, she slept in a tightly closed room heated with coal ember. She was found unconscious in the morning with poor ventilation. She had a rare presentation of popliteal vein thrombosis, pulmonary emboli, and possible tissue necrosis with carbon monoxide poisoning. Oxygen treatment with low-molecular-weight heparin (nadroparine) and warfarin therapy resulted in an improvement in both popliteal and pulmonarymore » circulations. In conclusion, the presence of pulmonary emboli should be sought in patients with carbon monoxide poisoning.« less

  5. 40 CFR 86.222-94 - Carbon monoxide analyzer calibration.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 18 2011-07-01 2011-07-01 false Carbon monoxide analyzer calibration... PROGRAMS (CONTINUED) CONTROL OF EMISSIONS FROM NEW AND IN-USE HIGHWAY VEHICLES AND ENGINES Emission... New Medium-Duty Passenger Vehicles; Cold Temperature Test Procedures § 86.222-94 Carbon monoxide...

  6. A Fluorescent Source NDIR Carbon Monoxide Analyzer

    NASA Technical Reports Server (NTRS)

    Link, W. T.; McClatchie, E. A.; Watson, D. A.; Compher, A. B.

    1971-01-01

    This paper describes a new technique for measuring trace quantities of carbon monoxide by the nondispersive infrared (NDIR) methods. The technique uses the property of infrared fluorescence in a gas to generate a specific source of radiation which is an exact match of the absorption spectrum of the fundamental band of carbon monoxide. This results in an instrument with high sensitivity and specificity for CO. A novel method of referencing using an isotopic species of CO confers great stability on the instrument.

  7. Carbon monoxide sensor and method of use

    DOEpatents

    Dutta, Prabir K.; Swartz, Scott L.; Holt, Christopher T.; Revur, Ramachandra Rao

    2006-01-10

    A sensor and method of use for detection of low levels of carbon monoxide in gas mixtures. The approach is based on the change in an electrical property (for example: resistance) that occurs when carbon monoxide is selectively absorbed by a film of copper chloride (or other metal halides). The electrical property change occurs rapidly with both increasing and decreasing CO contents, varies with the amount of CO from the gas stream, and is insensitive to the presence of hydrogen. To make a sensor using this approach, the metal halide film will deposited onto an alumina substrate with electrodes. The sensor may be maintained at the optimum temperature with a thick film platinum heater deposited onto the opposite face of the substrate. When the sensor is operating at an appropriate (and constant) temperature, the magnitude of the electrical property measured between the interdigital electrodes will provide a measure of the carbon monoxide content of the gas.

  8. Carbon Monoxide | Air Quality Planning Unit | Ground-level ...

    EPA Pesticide Factsheets

    2017-04-10

    Carbon monoxide (CO) is a colorless, odorless gas that can increase the severity of lung ailments, cause dizziness, fatigue, nausea, and even death. EPA has defined the national ambient air quality standard (NAAQS) for carbon monoxide as nine parts per million averaged over an eight-hour period, and this threshold cannot be exceeded more than once a year or an area would be violating the standard.

  9. CARBON MONOXIDE AND THE NERVOUS SYSTEM

    EPA Science Inventory

    Carbon monoxide (CO) is a colorless, tasteless, odorless, and non-irritating gas formed when carbon in fuel is not burned completely. It enters the bloodstream through the lungs and attaches to hemoglobin (Hb), the body's oxygen carrier, forming carboxyhemoglobin (COHb) and there...

  10. 40 CFR 86.1322-84 - Carbon monoxide analyzer calibration.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... be used. (2) Zero the carbon monoxide analyzer with either zero-grade air or zero-grade nitrogen. (3... columns is one form of corrective action which may be taken.) (b) Initial and periodic calibration. Prior... calibrated. (1) Adjust the analyzer to optimize performance. (2) Zero the carbon monoxide analyzer with...

  11. 40 CFR 86.122-78 - Carbon monoxide analyzer calibration.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... sensitive range to be used. (2) Zero the carbon monoxide analyzer with either zero-grade air or zero-grade... conditioning columns is one form of corrective action which may be taken.) (b) Initial and periodic calibration... calibrated. (1) Adjust the analyzer to optimize performance. (2) Zero the carbon monoxide analyzer with...

  12. Long-term measurements (2010-2014) of carbonaceous aerosol and carbon monoxide at the Zotino Tall Tower Observatory (ZOTTO) in central Siberia

    NASA Astrophysics Data System (ADS)

    Mikhailov, Eugene F.; Mironova, Svetlana; Mironov, Gregory; Vlasenko, Sergey; Panov, Alexey; Chi, Xuguang; Walter, David; Carbone, Samara; Artaxo, Paulo; Heimann, Martin; Lavric, Jost; Pöschl, Ulrich; Andreae, Meinrat O.

    2017-12-01

    We present long-term (5-year) measurements of particulate matter with an upper diameter limit of ˜ 10 µm (PM10), elemental carbon (EC), organic carbon (OC), and water-soluble organic carbon (WSOC) in aerosol filter samples collected at the Zotino Tall Tower Observatory in the middle-taiga subzone (Siberia). The data are complemented with carbon monoxide (CO) measurements. Air mass back trajectory analysis and satellite image analysis were used to characterise potential source regions and the transport pathway of haze plumes. Polluted and background periods were selected using a non-parametric statistical approach and analysed separately. In addition, near-pristine air masses were selected based on their EC concentrations being below the detection limit of our thermal-optical instrument. Over the entire sampling campaign, 75 and 48 % of air masses in winter and in summer, respectively, and 42 % in spring and fall are classified as polluted. The observed background concentrations of CO and EC showed a sine-like behaviour with a period of 365 ± 4 days, mostly due to different degrees of dilution and the removal of polluted air masses arriving at the Zotino Tall Tower Observatory (ZOTTO) from remote sources. Our analysis of the near-pristine conditions shows that the longest periods with clean air masses were observed in summer, with a frequency of 17 %, while in wintertime only 1 % can be classified as a clean. Against a background of low concentrations of CO, EC, and OC in the near-pristine summertime, it was possible to identify pollution plumes that most likely came from crude-oil production sites located in the oil-rich regions of Western Siberia. Overall, our analysis indicates that most of the time the Siberian region is impacted by atmospheric pollution arising from biomass burning and anthropogenic emissions. A relatively clean atmosphere can be observed mainly in summer, when polluted species are removed by precipitation and the aerosol burden returns to

  13. Carbon monoxide poisoning from waterpipe smoking: a retrospective cohort study.

    PubMed

    Eichhorn, Lars; Michaelis, Dirk; Kemmerer, Michael; Jüttner, Björn; Tetzlaff, Kay

    2018-04-01

    Waterpipe smoking may increasingly account for unintentional carbon monoxide poisoning, a serious health hazard with high morbidity and mortality. We aimed at identifying waterpipe smoking as a cause for carbon monoxide poisoning in a large critical care database of a specialty care referral center. This retrospective cohort study included patients with a history of exposure to waterpipe smoking and carbon monoxide blood gas levels >10% or presence of clinical symptoms compatible with CO poisoning admitted between January 2013 and December 2016. Patients' initial symptoms and carbon monoxide blood levels were retrieved from records and neurologic status was assessed before and after hyperbaric oxygen treatment. Sixty-one subjects with carbon monoxide poisoning were included [41 males, 20 females; mean age 23 (SD ± 6) years; range 13-45] with an initial mean carboxyhemoglobin of 26.93% (SD ± 9.72). Most common symptoms included syncope, dizziness, headache, and nausea; 75% had temporary syncope. Symptoms were not closely associated with blood COHb levels. CO poisoning after waterpipe smoking may present in young adults with a wide variability of symptoms from none to unconsciousness. Therefore diagnosis should be suspected even in the absence of symptoms.

  14. Carbon monoxide and methane adsorption of crude oil refinery using activated carbon from palm shells as biosorbent

    NASA Astrophysics Data System (ADS)

    Yuliusman; Afdhol, M. K.; Sanal, Alristo

    2018-03-01

    Carbon monoxide and methane gas are widely present in oil refineries. Off-potential gas is used as raw material for the petrochemical industry. In order for this off-gas to be utilized, carbon monoxide and methane must be removed from off-gas. This study aims to adsorb carbon monoxide and methane using activated carbon of palm shells and commercial activated carbon simultaneously. This research was conducted in 2 stages: 1) Preparation and characterization of activated carbon, 2) Carbon monoxide and methane adsorption test. The activation experiments using carbon dioxide at a flow rate of 150 ml/min yielded a surface area of 978.29 m2/g, Nitrogen at flow rate 150 ml/min yielded surface area 1241.48 m2/g, and carbon dioxide and nitrogen at a flow rate 200 ml/min yielded a surface area 300.37 m2/g. Adsorption of carbon monoxide and methane on activated carbon of palm shell systems yielded results in the amount of 0.5485 mg/g and 0.0649 mg/g and using commercial activated carbon yielded results in the amount of 0.5480 mg/g and 0.0650 mg/g

  15. Four-electron deoxygenative reductive coupling of carbon monoxide at a single metal site

    NASA Astrophysics Data System (ADS)

    Buss, Joshua A.; Agapie, Theodor

    2016-01-01

    Carbon dioxide is the ultimate source of the fossil fuels that are both central to modern life and problematic: their use increases atmospheric levels of greenhouse gases, and their availability is geopolitically constrained. Using carbon dioxide as a feedstock to produce synthetic fuels might, in principle, alleviate these concerns. Although many homogeneous and heterogeneous catalysts convert carbon dioxide to carbon monoxide, further deoxygenative coupling of carbon monoxide to generate useful multicarbon products is challenging. Molybdenum and vanadium nitrogenases are capable of converting carbon monoxide into hydrocarbons under mild conditions, using discrete electron and proton sources. Electrocatalytic reduction of carbon monoxide on copper catalysts also uses a combination of electrons and protons, while the industrial Fischer-Tropsch process uses dihydrogen as a combined source of electrons and electrophiles for carbon monoxide coupling at high temperatures and pressures. However, these enzymatic and heterogeneous systems are difficult to probe mechanistically. Molecular catalysts have been studied extensively to investigate the elementary steps by which carbon monoxide is deoxygenated and coupled, but a single metal site that can efficiently induce the required scission of carbon-oxygen bonds and generate carbon-carbon bonds has not yet been documented. Here we describe a molybdenum compound, supported by a terphenyl-diphosphine ligand, that activates and cleaves the strong carbon-oxygen bond of carbon monoxide, enacts carbon-carbon coupling, and spontaneously dissociates the resulting fragment. This complex four-electron transformation is enabled by the terphenyl-diphosphine ligand, which acts as an electron reservoir and exhibits the coordinative flexibility needed to stabilize the different intermediates involved in the overall reaction sequence. We anticipate that these design elements might help in the development of efficient catalysts for

  16. Carbon monoxide oxidation rates computed for automobile thermal reactor conditions

    NASA Technical Reports Server (NTRS)

    Brokaw, R. S.; Bittker, D. A.

    1972-01-01

    Carbon monoxide oxidation rates in thermal reactors for exhaust manifolds are computed by integrating differential equations for system of twenty-nine reversible chemical reactions. Reactors are noncatalytic replacements for conventional exhaust manifolds and are a system for reducing carbon monoxide and hydrocarbons in automobile exhausts.

  17. Mars in situ propellants: Carbon monoxide and oxygen ignition experiments

    NASA Technical Reports Server (NTRS)

    Linne, Diane L.; Roncace, James; Groth, Mary F.

    1990-01-01

    Carbon monoxide and oxygen were tested in a standard spark-torch igniter to identify the ignition characteristics of this potential Mars in situ propellant combination. The ignition profiles were determined as functions of mixture ratio, amount of hydrogen added to the carbon monoxide, and oxygen inlet temperature. The experiments indicated that the carbon monoxide and oxygen combination must have small amounts of hydrogen present to initiate reaction. Once the reaction was started, the combustion continued without the presence of hydrogen. A mixture ratio range was identified where ignition occurred, and this range varied with the oxygen inlet temperature.

  18. Compact Reconnaissance Imaging Spectrometer Observations of Water Vapor and Carbon Monoxide

    NASA Technical Reports Server (NTRS)

    Smith, Michael D.; Wolff, Michael J.; Clancy, R. Todd; Murchie, Scott L.

    2009-01-01

    The Compact Reconnaissance Imaging Spectrometer for Mars (CRISM) onboard the Mars Reconnaissance Orbiter (MRO) spacecraft began taking observations in September 2006 and has now collected more than a full Martian year of data. Retrievals performed using the near-infrared spectra obtained by CRISM are used to characterize the seasonal and spatial variation of the column abundance of water vapor and the column-averaged mixing ratio of carbon monoxide. CRISM retrievals show nominal behavior in water vapor during northern hemisphere spring and summer with maximum abundance reaching 50 precipitable micrometers. Water vapor abundance during the southern hemisphere spring and summer appears significantly reduced compared to observations by other instruments taken during previous years. The CRISM retrievals show the seasonally and globally averaged carbon monoxide mixing ratio to be 700 ppm, but with strong seasonal variations at high latitudes. The summertime near-polar carbon monoxide mixing ratio falls to 200 ppm in the south and 400 ppm in the north as carbon dioxide sublimates from the seasonal polar ice caps and dilutes noncondensable species including carbon monoxide. At low latitudes, the carbon monoxide mixing ratio varies in response to the mean seasonal cycle of surface pressure.

  19. Occupational carbon monoxide violations in the State of Washington, 1994-1999.

    PubMed

    Lofgren, Don J

    2002-07-01

    Occupational exposure to carbon monoxide continues to cause a number of injuries and deaths. This study reviewed the State of Washington OSHA inspection records for occupational safety or health violations related to carbon monoxide for the time period 1994-1999 to assess the agency's efforts and further identify and characterize causative factors. Inspection data were also compared with carbon monoxide claims data from a companion study to determine if the agency was visiting the most at risk work operations. Inspections were identified by searching computerized violation texts for "carbon monoxide" or "CO." The study found 142 inspections with one or more carbon monoxide violations. Inspections were spread over 84 different 4-digit Standard Industrial Classification codes. Most inspections were initiated as a result of a complaint or other informant. Inspections were predominantly in construction and manufacturing, whereas carbon monoxide claims were mores evenly distributed between the major industries. Inspections also may have failed to find violations for some types of equipment responsible for carbon monoxide claims. Forklifts were the source of carbon monoxide most often associated with a violation, followed by compressors for respirators, auto/truck/bus, and temporary heating devices. Inspections in response to poisonings found common factors associated with lack of recognition and failure to use or maintain equipment and ventilation. Some work sites with one or more poisonings were not being inspected. Only 10 of the 51 incidents with industrial insurance claim reports of carboxyhemoglobin at or above 20 percent were inspected. Further, it was found more preventive efforts should be targeted at cold storage operations and certain warehouse and construction activities. It is proposed that more specific standards, both consensus and regulatory, would provide additional risk reduction. Reliance upon safe work practices as a primary method of control in the

  20. Real World of Industrial Chemistry: Organic Chemicals from Carbon Monoxide.

    ERIC Educational Resources Information Center

    Kolb, Kenneth E.; Kolb, Doris

    1983-01-01

    Carbon Monoxide obtained from coal may serve as the source for a wide variety of organic compounds. Several of these compounds are discussed, including phosgene, benzaldehyde, methanol, formic acid and its derivatives, oxo aldehydes, acrylic acids, and others. Commercial reactions of carbon monoxide are highlighted in a table. (JN)

  1. Investigation of low temperature carbon monoxide oxidation catalysts. [for Spacelab atmosphere control

    NASA Technical Reports Server (NTRS)

    Jagow, R. B.; Katan, T.; Ray, C. D.; Lamparter, R. A.

    1977-01-01

    Carbon monoxide generation rates related to the use of commerical equipment in Spacelab, added to the normal metabolic and subsystem loads, will produce carbon monoxide levels in excess of the maximum allowable concentration. In connection with the sensitivity of carbon monoxide oxidation catalysts to poisoning at room temperature, catalysts for an oxidation of carbon monoxide at low temperatures have been investigated. It was found that platinum and palladium are the only effective room temperature catalysts which are effective at 333 K. Hopcalite was ineffective at ambient temperatures, but converted CO with 100 percent efficiency at 333 K. Poisoning tests showed the noble metal catalysts to be very sensitive, and Hopcalite to be very resistant to poisoning.

  2. High Resolution Trajectory-Based Smoke Forecasts Using VIIRS Aerosol Optical Depth and NUCAPS Carbon Monoxide Retrievals

    NASA Astrophysics Data System (ADS)

    Pierce, R. B.; Smith, N.; Barnet, C.; Barnet, C. D.; Kondragunta, S.; Davies, J. E.; Strabala, K.

    2016-12-01

    We use Suomi National Polar-orbiting Partnership (S-NPP) Visible Infrared Imaging Radiometer Suite (VIIRS) Aerosol Optical Depth (AOD) and combined Cross-track Infrared Sounder (CrIS) and Advanced Technology Microwave Sounder (ATMS) NOAA-Unique CrIS-ATMS Processing System (NUCAPS) carbon monoxide (CO) retrievals to initialize trajectory-based, high spatial resolution North American smoke dispersion forecasts during the May 2016 Fort McMurray wildfire in northern Alberta and the July 2016 Soberanes Fire in Northern California. These two case studies illustrate how long range transport of wild fire smoke can adversely impact surface air quality thousands of kilometers downwind and how local topographic flow can lead to complex transport patterns near the wildfire source region. The NUCAPS CO retrievals are shown to complement the high resolution VIIRS AOD retrievals by providing retrievals in partially cloudy scenes and also providing information on the vertical distribution of the wildfire smoke. This work addresses the need for low latency, web-based, high resolution forecasts of smoke dispersion for use by NWS Incident Meteorologists (IMET) to support on-site decision support services for fire incident management teams. The primary user community for the IDEA-I smoke forecasts is the Western regions of the NWS and US EPA due to the significant impacts of wildfires in these regions. Secondary users include Alaskan NWS offices and Western State and Local air quality management agencies such as the Western Regional Air Partnership (WRAP).

  3. Chemical Production of Vibrationally Excited Carbon Monoxide from Carbon Vapor and Molecular Oxygen Precursors

    NASA Astrophysics Data System (ADS)

    Frederickson, Kraig; Musci, Ben; Rich, J. William; Adamovich, Igor

    2015-09-01

    Recent results demonstrating the formation of vibrationally excited carbon monoxide from carbon vapor and molecular oxygen will be presented. Previous reaction dynamics simulations and crossed molecular beam experiments have shown that gas-phase reaction of carbon atoms and molecular oxygen produces vibrationally excited carbon monoxide. The present work examines the product distribution of this reaction in a collision dominated environment, at a pressure of several Torr. Carbon vapor is produced in an AC arc discharge in argon buffer operated at a voltage of approximately 1 kV and current of 10 A, and mixed with molecular oxygen, which may also be excited by an auxiliary RF discharge, in a flowing chemical reactor. Identification of chemical reaction products and inference of their vibrational populations is performed by comparing infrared emission spectra of the flow in the reactor, taken by a Fourier Transform IR spectrometer, with synthetic spectra. Estimates of vibrationally excited carbon monoxide concentration and relative vibrational level populations will be presented.

  4. Anthropogenic emissions of carbon monoxide.

    PubMed

    Horner, J M

    2000-01-01

    Carbon monoxide (CO) is a colorless, nonirritating, odorless and tasteless gas. Carbon monoxide combines with hemoglobin far more readily than does oxygen, leading to tissue hypoxia. Thousands of people die annually from CO poisoning, and those recovering from acute exposure commonly suffer brain damage. Chronic poisoning is of particular concern to sufferers of coronary heart disease, pregnant women, and people with certain hematological disorders. Indoor emission sources, notably fuel-burning heating appliances, cause most unintentional deaths and cases of illness and should be the main focus of concern. Motor vehicle emissions pose a chronic health risk for occupationally exposed groups. Smoking is a major source of personal exposure. Recent exposure to CO is commonly evaluated by measuring blood carboxyhemoglobin levels, which are related to the concentration of atmospheric CO. Monitoring methods are reviewed here, and monitoring is considered in relation to air quality standards and guidelines. Finally, control measures for motor vehicles and indoor heating appliances are suggested.

  5. Fatal carbon monoxide intoxication after acetylene gas welding of pipes.

    PubMed

    Antonsson, Ann-Beth; Christensson, Bengt; Berge, Johan; Sjögren, Bengt

    2013-06-01

    Acetylene gas welding of district heating pipes can result in exposure to high concentrations of carbon monoxide. A fatal case due to intoxication is described. Measurements of carbon monoxide revealed high levels when gas welding a pipe with closed ends. This fatality and these measurements highlight a new hazard, which must be promptly prevented.

  6. Non-ST elevation myocardial infarction secondary to carbon monoxide intoxication

    PubMed Central

    Jankowska, Danuta; Palabindala, Venkataraman; Salim, Sohail Abdul

    2017-01-01

    ABSTRACT Carbon monoxide poisoning has been documented in literature to cause severe neurological and tissue toxicity within the body. However, cardiotoxicity is often overlooked, but not uncommon. Previous research studies and case reports have revealed a significant relationship between carbon monoxide intoxication and myocardial ischemic events. We report a case of a 48-year-old male, who was exposed to severe smoke inhalation due to a house fire and subsequently developed a non-ST elevation myocardial infarction. Ischemic changes were evident on electrocardiogram, which demonstrated T-wave inversion in lead III and ST-segment depression in leads V4-V6. Elevated cardiac enzymes were also present. After standard treatment for an acute cardiac event, the patient fully recovered. This case demonstrates that myocardial ischemic changes due to carbon monoxide poisoning may be reversible if recognized in early stages and treated appropriately, thus reminding physicians that a proper cardiovascular examination and diagnostic testing should be performed on all patients with carbon monoxide poisoning. Abbreviations: NSTEMI: Non-ST elevation myocardial infarction PMID:28638579

  7. Terpolymerization of ethylene, sulfur dioxide and carbon monoxide

    DOEpatents

    Johnson, Richard; Steinberg, Meyer

    1981-01-01

    This invention relates to a high molecular weight terpolymer of ethylene, sulfur dioxide and carbon monoxide stable to 280.degree. C. and containing as little as 36 mol % ethylene and about 41-51 mol % sulfur dioxide; and to the method of producing said terpolymer by irradiation of a liquid and gaseous mixture of ethylene, sulfur dioxide and carbon monoxide by means of Co-60 gamma rays or an electron beam, at a temperature of about 10.degree.-50.degree. C., and at a pressure of about 140 to 680 atmospheres, to initiate polymerization.

  8. Separation of Carbon Monoxide and Carbon Dioxide for Mars ISRU-Concepts

    NASA Technical Reports Server (NTRS)

    LeVan, M. Douglas; Finn, John E.; Sridhar, K. R.

    2000-01-01

    Solid oxide electrolyzers, such as electrolysis cells utilizing yttria-stabilized zirconia, can produce oxygen from Mars atmospheric carbon dioxide and reject carbon monoxide and unreacted carbon dioxide in a separate stream. The oxygen-production process has been shown to be far more efficient if the high-pressure, unreacted carbon dioxide can be separated and recycled back into the feed stream. Additionally, the mass of the adsorption compressor can be reduced. Also, the carbon monoxide by-product is a valuable fuel for space exploration and habitation, with applications from fuel cells to production of hydrocarbons and plastics. In our research, we will design, construct, and test an innovative, robust, low mass, low power separation device that can recover carbon dioxide and carbon monoxide for Mars ISRU. Such fundamental process technology, involving gas-solid phase separation in a reduced gravitational environment, will help to enable Human Exploration and Development of Space. The separation device will be scaled to operate with a CO2 sorption compressor and a zirconia electrolysis device built at the NASA Ames Research Center and the University of Arizona, respectively. In our research, we will design, construct, and test an innovative, robust, low mass, low power separation device that can recover carbon dioxide and carbon monoxide for Mars ISRU, Such fundamental process technology, involving gas-solid phase separation in a reduced gravitational environment, will help to enable Human Exploration and Development of Space. The separation device will be scaled to operate with a CO2 sorption compressor and a zirconia electrolysis device built at the NASA Ames Research Center and the University of Arizona, The separation device will be scaled to operate with a CO2 sorption compressor and a zirconia electrolysis device built at the NASA Ames Research Center and the University of Arizona, Research needs for the design shown are as follows: (1) The best adsorbent

  9. Carbon monoxide exposure in households in Ciudad Juárez, México.

    PubMed

    Montoya, Teresa; Gurian, Patrick L; Velázquez-Angulo, Gilberto; Corella-Barud, Verónica; Rojo, Analila; Graham, Jay P

    2008-03-01

    This study assessed exposure to carbon monoxide from gas and wood heater emissions in a sample of 64 households in peri-urban residential areas in Ciudad Juárez, Chihuahua, México. Indoor and outdoor carbon monoxide concentrations and temperatures were monitored for a continuous period of 1 week at 1 and 6-min intervals, respectively. The moving average carbon monoxide concentrations were compared to the World Health Organization (WHO) standards for carbon monoxide. Sixty-seven percent of households with gas heaters and 60% of households with wood heaters exceeded a health-based standard at some point during the monitoring. The difference between indoor and outdoor temperatures was modestly correlated with average carbon monoxide exposure (r=0.35, p-value <0.01). Heater type may be a stronger determinant of exposure, as households with a particular heater model (the El Sol FM-210) were significantly more likely to be among the more highly exposed households (odds ratio of 4.8, p-value of 0.02). A variety of health effects were pooled and found at elevated frequency in the households that exceeded the 8-h standard of 9ppm (odds ratio=5.1, p-value=0.031). These results highlight the need for further efforts to identify and mitigate potentially hazardous carbon monoxide exposures, particularly in moderate-income countries with cooler climates.

  10. Production of carbon monoxide-free hydrogen and helium from a high-purity source

    DOEpatents

    Golden, Timothy Christopher [Allentown, PA; Farris, Thomas Stephen [Bethlehem, PA

    2008-11-18

    The invention provides vacuum swing adsorption processes that produce an essentially carbon monoxide-free hydrogen or helium gas stream from, respectively, a high-purity (e.g., pipeline grade) hydrogen or helium gas stream using one or two adsorber beds. By using physical adsorbents with high heats of nitrogen adsorption, intermediate heats of carbon monoxide adsorption, and low heats of hydrogen and helium adsorption, and by using vacuum purging and high feed stream pressures (e.g., pressures of as high as around 1,000 bar), pipeline grade hydrogen or helium can purified to produce essentially carbon monoxide -free hydrogen and helium, or carbon monoxide, nitrogen, and methane-free hydrogen and helium.

  11. Process for producing methane from gas streams containing carbon monoxide and hydrogen

    DOEpatents

    Frost, Albert C.

    1980-01-01

    Carbon monoxide-containing gas streams are passed over a catalyst capable of catalyzing the disproportionation of carbon monoxide so as to deposit a surface layer of active surface carbon on the catalyst essentially without formation of inactive coke thereon. The surface layer is contacted with steam and is thus converted to methane and CO.sub.2, from which a relatively pure methane product may be obtained. While carbon monoxide-containing gas streams having hydrogen or water present therein can be used only the carbon monoxide available after reaction with said hydrogen or water is decomposed to form said active surface carbon. Although hydrogen or water will be converted, partially or completely, to methane that can be utilized in a combustion zone to generate heat for steam production or other energy recovery purposes, said hydrogen is selectively removed from a CO--H.sub.2 -containing feed stream by partial oxidation thereof prior to disproportionation of the CO content of said stream.

  12. 40 CFR 51.241 - Nonattainment areas for carbon monoxide and ozone.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Intergovernmental Consultation Agency Designation § 51.241 Nonattainment areas for carbon monoxide and ozone. (a... 40 Protection of Environment 2 2011-07-01 2011-07-01 false Nonattainment areas for carbon monoxide and ozone. 51.241 Section 51.241 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED...

  13. 40 CFR 51.241 - Nonattainment areas for carbon monoxide and ozone.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Intergovernmental Consultation Agency Designation § 51.241 Nonattainment areas for carbon monoxide and ozone. (a... 40 Protection of Environment 2 2014-07-01 2014-07-01 false Nonattainment areas for carbon monoxide and ozone. 51.241 Section 51.241 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED...

  14. 40 CFR 51.241 - Nonattainment areas for carbon monoxide and ozone.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Intergovernmental Consultation Agency Designation § 51.241 Nonattainment areas for carbon monoxide and ozone. (a... 40 Protection of Environment 2 2013-07-01 2013-07-01 false Nonattainment areas for carbon monoxide and ozone. 51.241 Section 51.241 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED...

  15. 40 CFR 51.241 - Nonattainment areas for carbon monoxide and ozone.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Intergovernmental Consultation Agency Designation § 51.241 Nonattainment areas for carbon monoxide and ozone. (a... 40 Protection of Environment 2 2010-07-01 2010-07-01 false Nonattainment areas for carbon monoxide and ozone. 51.241 Section 51.241 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED...

  16. 40 CFR 51.241 - Nonattainment areas for carbon monoxide and ozone.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Intergovernmental Consultation Agency Designation § 51.241 Nonattainment areas for carbon monoxide and ozone. (a... 40 Protection of Environment 2 2012-07-01 2012-07-01 false Nonattainment areas for carbon monoxide and ozone. 51.241 Section 51.241 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED...

  17. Sciatic neuropathy and rhabdomyolysis after carbon monoxide intoxication: A case report.

    PubMed

    Lee, Hyeok Dong; Lee, Sung Young; Cho, Young-Shin; Han, Seung Hoon; Park, Si-Bog; Lee, Kyu Hoon

    2018-06-01

    Peripheral neuropathy is a rare complication of carbon monoxide intoxication. Peripheral neuropathy following carbon monoxide intoxication is known to completely recover within a few months. A 40-year-old man complained of motor weakness and hypoesthesia of the right lower extremity with swelling of his right thigh after carbon monoxide intoxication resulting from a suicide attempt. Following nerve conduction and electromyographic studies, the patient was diagnosed with sciatic neuropathy with severe axonopathy. Clinical and laboratory findings led to a diagnosis of rhabdomyolysis. The patient was treated conservatively for rhabdomyolysis and underwent comprehensive rehabilitation for sciatic neuropathy during hospitalization. After discharge, he underwent serial follow-up tests with nerve conduction and electromyographic studies, which showed prolonged persistence of sciatic neuropathy; however, he showed significant improvement at his 26-month post-discharge follow-up. Patients presenting with peripheral neuropathy secondary to carbon monoxide intoxication may show variable recovery periods; however, a favorable prognosis can be expected regardless of the concomitant occurrence of rhabdomyolysis and/or compartment syndrome.

  18. Carbon monoxide screen for signalized intersections : COSIM, version 4.0 - technical documentation.

    DOT National Transportation Integrated Search

    2013-06-01

    Illinois Carbon Monoxide Screen for Intersection Modeling (COSIM) Version 3.0 is a Windows-based computer : program currently used by the Illinois Department of Transportation (IDOT) to estimate worst-case carbon : monoxide (CO) concentrations near s...

  19. Occupational carbon monoxide poisoning in the State of Washington, 1994-1999.

    PubMed

    Lofgren, Don J

    2002-04-01

    Carbon monoxide poisonings continue to be significant and preventable for a number of work operations. This study assesses occupational carbon monoxide morbidity and mortality for the state of Washington based on a review of workers' compensation records for the years 1994-1999. The study characterizes sources, industries, and causative factors, and further attempts to identify work operations most at risk. Records were identified by both injury source and diagnostic codes. The study limits itself to non-fire-related carbon monoxide poisonings and primarily those from acute exposure. A decline in the number of claims was not evident, but the number of incidents per year showed a slight decline. Carbon monoxide poisonings were found to occur throughout all types of industries. The greatest number of claims was found in agriculture, followed by construction and wholesale trade, with these three accounting for more than half the claims and nearly half of the incidents. The more severe poisonings did not necessarily occur in industries with the greatest number of incidents. The major source for carbon monoxide poisoning was forklift trucks, followed by auto/truck/bus, portable saws, and more than 20 other sources. Fruit packing and storage had the highest number of incidents mostly due to fuel-powered forklift activity, with nearly half of the incidents occurring in cold rooms. Adverse health effects as measured by carboxyhemoglobin, hyperbaric oxygen treatment, unconsciousness, and number and cost of claims were indexed by source. Though several specific work operations were identified, the episodic nature of carbon monoxide poisonings, as well as the diverse industries and sources, and the opportunity for a severe poisoning in any number of operations, poses challenges for effective intervention.

  20. Terpolymerization of ethylene, sulfur dioxide and carbon monoxide

    DOEpatents

    Johnson, R.; Steinberg, M.

    This invention relates to high molecular weight terpolymer of ethylene, sulfur dioxide and carbon monoxide stable to 280/sup 0/C and containing as little as 36 mo1% ethylene and about 41 to 51 mo1% sulfur dioxide, and to the method of producing said terpolymer by irradiation of a liquid and gaseous mixture of ethylene, sulfur dioxide and carbon monoxide by means of Co-60 gamma rays or an electron beam, at a temperature of about 10 to 50/sup 0/C, and at a pressure of about 140 to 680 atmospheres, to initiate polymerization.

  1. 77 FR 8252 - Adequacy Status of the Anchorage, Alaska, Carbon Monoxide Maintenance Plan for Transportation...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-02-14

    ... Anchorage, Alaska, Carbon Monoxide Maintenance Plan for Transportation Conformity Purposes AGENCY..., Alaska, Carbon Monoxide (CO) Maintenance Plan, submitted by the State of Alaska on September 20, 2011, is... adequacy finding regarding the motor vehicle emissions budget (MVEB) in the carbon monoxide Maintenance...

  2. Experimental evaluation of the ignition process of carbon monoxide and oxygen in a rocket engine

    NASA Technical Reports Server (NTRS)

    Linne, Diane L.

    1996-01-01

    Carbon monoxide and oxygen ignition boundaries were determined in a spark torch igniter as a function of propellant inlet temperatures. The oxygen temperature was varied from ambient to -258 F, and the carbon monoxide temperature was varied from ambient to -241 F. With the oxygen and carbon monoxide at -253 F and -219 F, respectively, they successfully ignited between mixture ratios of 2.42 and 3.10. Analysis of the results indicated that the lower ignition boundary was more sensitive to oxygen temperature than to carbon monoxide temperature. Another series of tests was performed in a small simulated rocket engine with oxygen at -197 F and carbon monoxide at -193 F. An oxygen/hydrogen flame was used to initiate combustion of the oxygen and carbon monoxide. Tests performed at the optimum operating mixture ratio of 0.55 obtained steady-state combustion in every test.

  3. The Distribution of Carbon Monoxide in the GOCART Model

    NASA Technical Reports Server (NTRS)

    Fan, Xiaobiao; Chin, Mian; Einaudi, Franco (Technical Monitor)

    2000-01-01

    Carbon monoxide (CO) is an important trace gas because it is a significant source of tropospheric Ozone (O3) as well as a major sink for atmospheric hydroxyl radical (OH). The distribution of CO is set by a balance between the emissions, transport, and chemical processes in the atmosphere. The Georgia Tech/Goddard Global Ozone Chemistry Aerosol Radiation and Transport (GOCART) model is used to simulate the atmospheric distribution of CO. The GOCART model is driven by the assimilated meteorological data from the Goddard Earth Observing System Data Assimilation System (GEOS DAS) in an off-line mode. We study the distribution of CO on three time scales: (1) day to day fluctuation produced by the synoptic waves; (2) seasonal changes due to the annual cycle of CO sources and sinks; and (3) interannual variability induced by dynamics. Comparison of model results with ground based and remote sensing measurements will also be presented.

  4. Inhalation toxicology. XI., The effect of elevated temperature on carbon monoxide toxicity.

    DOT National Transportation Integrated Search

    1990-12-01

    Laboratory rats were exposed (a) to experimental concentrations of carbon monoxide in air at ambient temperature, (b) to elevated temperature atmospheres from 40 C to 60 C, and (c) to selected carbon monoxide (CO) concentrations at the elevated tem...

  5. Fermentative production of ethanol from carbon monoxide.

    PubMed

    Köpke, Michael; Mihalcea, Christophe; Bromley, Jason C; Simpson, Séan D

    2011-06-01

    'Too much Carbon Monoxide for me to bear…' are the opening lyrics of the CAKE song Carbon Monoxide (from their 2004 album Pressure Chief), and while this may be the case for most living organisms, several species of bacteria both thrive on this otherwise toxic gas, and metabolize it for the production of fuels and chemicals. Indeed CO fermentation offers the opportunity to sustainably produce fuels and chemicals without impacting the availability of food resources or even farm land. Mounting commercial interest in the potential of this process has in turn triggered greater scrutiny of the molecular and genetic basis for CO metabolism, as well as the challenges associated with the implementation and operation of gas fermentation at scale. Copyright © 2011 Elsevier Ltd. All rights reserved.

  6. A review of carbon monoxide sources, sinks, and concentrations in the earth's atmosphere

    NASA Technical Reports Server (NTRS)

    Bortner, M. H.; Kummler, R. H.; Jaffe, L. S.

    1972-01-01

    Carbon monoxide is a toxic pollutant which is continually introduced into the earth's atmosphere in significant quantities. There are apparently some mechanisms operating which destroy most of the CO in the atmosphere, i.e., a carbon monoxide sink. These mechanisms have not as yet been established in a quantitative sense. This report discusses the various possible removal mechanisms which warrant serious consideration. Particular emphasis is given to chemical reactions (especially that with OH), soil bacteria and other biological action, and transport effects. The sources of carbon monoxide, both natural and anthropogenic, are reviewed and it is noted that there is quite possibly a significant undefined natural source. Atmospheric CO concentrations are discussed and their implications on carbon monoxide lifetime, sinks and sources are considered.

  7. METEOROLOGICAL FACTORS RESPONSIBLE FOR HIGH CO (CARBON MONOXIDE) LEVELS IN ALASKAN CITIES

    EPA Science Inventory

    High winter carbon monoxide levels in Anchorage, as in Fairbanks, are due to intense nocturnal (ground-based) inversions persisting through the periods of maximum emissions and at times throughout the day. The problem is exacerbated by the large amounts of carbon monoxide emitted...

  8. Cyclic process for producing methane from carbon monoxide with heat removal

    DOEpatents

    Frost, Albert C.; Yang, Chang-lee

    1982-01-01

    Carbon monoxide-containing gas streams are converted to methane by a cyclic, essentially two-step process in which said carbon monoxide is disproportionated to form carbon dioxide and active surface carbon deposited on the surface of a catalyst, and said carbon is reacted with steam to form product methane and by-product carbon dioxide. The exothermic heat of reaction generated in each step is effectively removed during each complete cycle so as to avoid a build up of heat from cycle-to-cycle, with particularly advantageous techniques being employed for fixed bed, tubular and fluidized bed reactor operations.

  9. Substantially isotactic, linear, alternating copolymers of carbon monoxide and an olefin

    DOEpatents

    Sen, Ayusman; Jiang, Zhaozhong

    1996-01-01

    The compound, [Pd(Me-DUPHOS)(MeCN).sub.2 ](BF.sub.4).sub.2, [Me-DUPHOS: 1,2-bis(2,5-dimethylphospholano)benzene] is an effective catalyst for the highly enantioselective, alternating copolymerization of olefins, such as aliphatic .alpha.-olefins, with carbon monoxide to form optically active, isotactic polymers which can serve as excellent starting materials for the synthesis of other classes of chiral polymers. For example, the complete reduction of a propylene-carbon monoxide copolymer resulted in the formation of a novel, optically active poly(1,4-alcohol). Also, the previously described catalyst is a catalyst for the novel alternating isomerization cooligomerization of 2-butene with carbon monoxide to form optically active, isotactic poly(1,5-ketone)

  10. Substantially isotactic, linear, alternating copolymers of carbon monoxide and an olefin

    DOEpatents

    Sen, A.; Jiang, Z.

    1996-05-28

    The compound, [Pd(Me-DUPHOS)(MeCN){sub 2}](BF{sub 4}){sub 2}, [Me-DUPHOS: 1,2-bis(2,5-dimethylphospholano)benzene] is an effective catalyst for the highly enantioselective, alternating copolymerization of olefins, such as aliphatic {alpha}-olefins, with carbon monoxide to form optically active, isotactic polymers which can serve as excellent starting materials for the synthesis of other classes of chiral polymers. For example, the complete reduction of a propylene-carbon monoxide copolymer resulted in the formation of a novel, optically active poly(1,4-alcohol). Also, the previously described catalyst is a catalyst for the novel alternating isomerization cooligomerization of 2-butene with carbon monoxide to form optically active, isotactic poly(1,5-ketone).

  11. Unusual presentation of death due to carbon monoxide poisoning. A report of two cases.

    PubMed

    Ruszkiewicz, A; de Boer, B; Robertson, S

    1997-06-01

    Two cases are reported representing opposite ends of the spectrum of death as a result of carbon monoxide poisoning from car exhaust fumes. In one case, a women was reported to be found dead in bed early in the morning by her husband. The cause of her death, established by autopsy, was carbon monoxide poisoning. Toxicology examination indicated a car engine as the possible source of carbon monoxide. The mode of administration was never established. In the second case, a women was found in a car located in her garage with a hose leading from the exhaust pipe to the interior of the sealed vehicle. Autopsy revealed negligible carboxyhemoglobin saturation of the blood, bilateral infarction of the globus pallidus, and extensive bronchopneumonia. It was concluded that inhalation of carbon monoxide resulted in sublethal hypoxia with subsequent exhalation of carbon monoxide and a delayed death.

  12. Enhanced carbon monoxide utilization in methanation process

    DOEpatents

    Elek, Louis F.; Frost, Albert C.

    1984-01-01

    Carbon monoxide - containing gas streams are passed over a catalyst to deposit a surface layer of active surface carbon thereon essentially without the formation of inactive coke. The active carbon is subsequently reacted with steam or hydrogen to form methane. Surprisingly, hydrogen and water vapor present in the feed gas do not adversely affect CO utilization significantly, and such hydrogen actually results in a significant increase in CO utilization.

  13. Removal of carbon monoxide. Physical adsorption on natural and synthetic zeolites

    NASA Technical Reports Server (NTRS)

    Alfani, F.; Greco, G., Jr.; Iroio, G.

    1982-01-01

    The utilization of natural zeolite materials in the elimination of polluting gases is investigated. Carbon monoxide pollution is emphasized because its concentration may reach dangerous levels in places such as vehicle tunnels, underground parking lots, etc. The elimination of carbon monoxide is also of interest in some industrial processes relating to the production of pure gases.

  14. Carbon monoxide and lethal arrhythmias. Research report, Jul 85-Jan 89

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Farber, J.P.; Schwartz, P.J.; Vanoli, E.

    1990-01-01

    The effect of acute exposure to carbon monoxide on ventricular arrhythmias was studied in dogs with a healed anterior myocardial infarction. The combination of mild exercise and acute myocardial ischemia induces ventricular fibrillation in 60 percent of the animals. Dogs that develop ventricular fibrillation are considered at high risk for sudden death and are defined as susceptible; dogs that survive the test without fatal arrhythmia are considered at low risk and are defined as 'resistant.' The effects of carboxyhemoglobin levels ranging from 5 to 15 percent were tested in resistant and susceptible dogs. A trend toward higher heart rates wasmore » observed at rest and during exercise in both resistant and susceptible dogs at all levels of carboxyhemoglobin, although significant differences were observed only with 15 percent carboxyhemoglobin. In resistant animals, in which acute myocardial ischemia is typically associated with bradycardia even under the control condition, the reflex response occurred earlier and was augmented after exposure to carbon monoxide. In both resistant and susceptible dogs, carbon monoxide exposure induced a worsening of ventricular arrhythmias in a minority of cases. The worsening was not reproducible in subsequent trials. These data indicate that acute exposure to carbon monoxide is seldom arrhythmogenic in dogs that have survived myocardial infarction. Nevertheless, the observation that carbon monoxide exposure increases heart rate at rest and during moderate exercise may have clinical implications relevant to patients with coronary artery disease.« less

  15. Catalytic Copolymerization of Ethene and Carbon Monoxide on Nickel Complexes.

    PubMed

    Domhöver, Bernd; Kläui, Wolfgang; Kremer-Aach, Andreas; Bell, Ralf; Mootz, Dietrich

    1998-11-16

    Can palladium be replaced by nickel? For the industrial copolymerization of carbon monoxide and ethene a palladium catalyst is used which cannot be recovered-a cheaper procedure would be desirable. The presented complex 1 is the first structurally characterized nickel compound which does not polymerize ethene but a mixture from carbon monoxide and ethene unter mild conditions to give a perfectly alternating polyketone. © 1998 WILEY-VCH Verlag GmbH, Weinheim, Fed. Rep. of Germany.

  16. Carbon monoxide toxicity. (Latest citations from the Life Sciences Collection database). NewSearch

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    The bibliography contains citations concerning the mechanism and clinical manifestations of carbon monoxide (CO) exposure, including the effects on the liver, cardiovascular, and nervous systems. Topics include studies of the carbon monoxide binding affinity with hemoglobin, measurement of carboxyhemoglobin in humans and various animal species, carbon monoxide levels resulting from tobacco and marijuana smoke, occupational exposure and the NIOSH (National Institute for Occupational Safety and Health) biological exposure index, symptomology and percent of blood CO, and intrauterine exposure. Air pollution, tobacco smoking, and occupational exposure are discussed as primary sources of carbon monoxide exposure. The effects of cigarette smoking onmore » fetal development and health are excluded and examined in a separate bibliography. (Contains a minimum of 137 citations and includes a subject term index and title list.)« less

  17. Carbon monoxide toxicity. (Latest citations from the Life Sciences Collection database). Published Search

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    The bibliography contains citations concerning the mechanism and clinical manifestations of carbon monoxide (CO) exposure, including the effects on the liver, cardiovascular, and nervous systems. Topics include studies of the carbon monoxide binding affinity with hemoglobin, measurement of carboxyhemoglobin in humans and various animal species, carbon monoxide levels resulting from tobacco and marijuana smoke, occupational exposure and the NIOSH (National Institute for Occupational Safety and Health) biological exposure index, symptomology and percent of blood CO, and intrauterine exposure. Air pollution, tobacco smoking, and occupational exposure are discussed as primary sources of carbon monoxide exposure. The effects of cigarette smoking onmore » fetal development and health are excluded and examined in a separate bibliography.(Contains 50-250 citations and includes a subject term index and title list.) (Copyright NERAC, Inc. 1995)« less

  18. Carbon monoxide toxicity. (Latest citations from the Life Sciences Collection database). Published Search

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    The bibliography contains citations concerning the mechanism and clinical manifestations of carbon monoxide (CO) exposure, including the effects on the liver, cardiovascular, and nervous systems. Topics include studies of the carbon monoxide binding affinity with hemoglobin, measurement of carboxyhemoglobin in humans and various animal species, carbon monoxide levels resulting from tobacco and marijuana smoke, occupational exposure and the NIOSH (National Institute for Occupational Safety and Health) biological exposure index, symptomology and percent of blood CO, and intrauterine exposure. Air pollution, tobacco smoking, and occupational exposure are discussed as primary sources of carbon monoxide exposure. The effects of cigarette smoking onmore » fetal development and health are excluded and examined in a separate bibliography. (Contains 50-250 citations and includes a subject term index and title list.) (Copyright NERAC, Inc. 1995)« less

  19. Digital image analysis of fingernail colour in cadavers comparing carbon monoxide poisoning to controls.

    PubMed

    Langlois, Neil E I

    2010-03-01

    Carbon monoxide is a component of motor vehicle exhaust fumes, provided a functional catalytic converter is not present. This gas binds avidly to the hemoglobin molecule in red blood cells preventing its oxygen transport function, effectively poisoning the body by starving it of oxygen. In binding to hemoglobin, carbon monoxide forms carboxyhemoglobin, which has a characteristic bright pink color. It has been remarked that the fingernails of victims of carbon monoxide tend to exhibit pink color, otherwise fingernails of deceased bodies tend towards a dark red to blue color. This study sought to objectively determine by using digital image analysis if a color difference occurred between the fingernails of a group of cadavers with carbon monoxide poisoning compared to a group of controls. The fingernails of the carbon monoxide group did tend to be more red than the controls, but due to overlap between the two groups assessment of the fingernails cannot be recommended as a rapid screening test.

  20. 40 CFR 89.112 - Oxides of nitrogen, carbon monoxide, hydrocarbon, and particulate matter exhaust emission standards.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 21 2013-07-01 2013-07-01 false Oxides of nitrogen, carbon monoxide....112 Oxides of nitrogen, carbon monoxide, hydrocarbon, and particulate matter exhaust emission... emissions of oxides of nitrogen, carbon monoxide, hydrocarbon, and nonmethane hydrocarbon are measured using...

  1. 40 CFR 89.112 - Oxides of nitrogen, carbon monoxide, hydrocarbon, and particulate matter exhaust emission standards.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 21 2012-07-01 2012-07-01 false Oxides of nitrogen, carbon monoxide....112 Oxides of nitrogen, carbon monoxide, hydrocarbon, and particulate matter exhaust emission... emissions of oxides of nitrogen, carbon monoxide, hydrocarbon, and nonmethane hydrocarbon are measured using...

  2. 40 CFR 89.112 - Oxides of nitrogen, carbon monoxide, hydrocarbon, and particulate matter exhaust emission standards.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 20 2014-07-01 2013-07-01 true Oxides of nitrogen, carbon monoxide....112 Oxides of nitrogen, carbon monoxide, hydrocarbon, and particulate matter exhaust emission... emissions of oxides of nitrogen, carbon monoxide, hydrocarbon, and nonmethane hydrocarbon are measured using...

  3. Long-term measurements of aerosol and carbon monoxide at the ZOTTO tall tower to characterize polluted and pristine air in the Siberian taiga

    NASA Astrophysics Data System (ADS)

    Chi, X.; Winderlich, J.; Mayer, J.-C.; Panov, A. V.; Heimann, M.; Birmili, W.; Heintzenberg, J.; Cheng, Y.; Andreae, M. O.

    2013-12-01

    Siberia is one of few continental regions in the Northern Hemisphere where the atmosphere may sometimes approach pristine background conditions. We present the time series of aerosol and carbon monoxide (CO) measurements between September 2006 and December 2011 at the Zotino Tall Tower Observatory (ZOTTO) in Central Siberia (61° N; 89° E). We investigate the seasonal, weekly and diurnal variations of aerosol properties (including absorption and scattering coefficients and derived parameters, such as equivalent black carbon (BCe), Ångström exponent, single scattering albedo, and backscattering ratio) and the CO mixing ratios. Criteria were established to distinguish polluted from near-pristine air masses, providing quantitative characteristics for each type. Depending on the season, 23-36% of the sampling time at ZOTTO was found to be representative of a clean atmosphere. The summer pristine data indicate that primary biogenic and secondary organic aerosol formation are quite strong particle sources in the Siberian taiga. The summer seasons 2007-2008 were dominated by an Aitken mode around 80 nm size, whereas the summer 2009 with prevailing easterly winds produced particles in the accumulation mode around 200 nm size. We found these differences to be mainly related to air temperature, through its effect on the production rates of biogenic volatile organic compounds (VOC) precursor gases. In winter, the particle size distribution peaked at 160 nm, and the footprint of clean background air was characteristic for aged particles from anthropogenic sources at great distances from ZOTTO and diluted biofuel burning emissions from domestic heating. The wintertime polluted air originates mainly from large cities south and southwest of the site; these particles have a dominant mode around 100 nm, and the ΔBCe / ΔCO ratio of 7-11 ng m-3 ppb-1 suggests dominant contributions from coal and biofuel burning for heating. During summer, anthropogenic emissions are the dominant

  4. 40 CFR 415.330 - Applicability; description of the carbon monoxide and by-product hydrogen production subcategory.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... carbon monoxide and by-product hydrogen production subcategory. 415.330 Section 415.330 Protection of... MANUFACTURING POINT SOURCE CATEGORY Carbon Monoxide and By-Product Hydrogen Production Subcategory § 415.330 Applicability; description of the carbon monoxide and by-product hydrogen production subcategory. The provisions...

  5. 40 CFR 415.330 - Applicability; description of the carbon monoxide and by-product hydrogen production subcategory.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... carbon monoxide and by-product hydrogen production subcategory. 415.330 Section 415.330 Protection of... MANUFACTURING POINT SOURCE CATEGORY Carbon Monoxide and By-Product Hydrogen Production Subcategory § 415.330 Applicability; description of the carbon monoxide and by-product hydrogen production subcategory. The provisions...

  6. 40 CFR 415.330 - Applicability; description of the carbon monoxide and by-product hydrogen production subcategory.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... carbon monoxide and by-product hydrogen production subcategory. 415.330 Section 415.330 Protection of... MANUFACTURING POINT SOURCE CATEGORY Carbon Monoxide and By-Product Hydrogen Production Subcategory § 415.330 Applicability; description of the carbon monoxide and by-product hydrogen production subcategory. The provisions...

  7. 40 CFR 415.330 - Applicability; description of the carbon monoxide and by-product hydrogen production subcategory.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... carbon monoxide and by-product hydrogen production subcategory. 415.330 Section 415.330 Protection of... MANUFACTURING POINT SOURCE CATEGORY Carbon Monoxide and By-Product Hydrogen Production Subcategory § 415.330 Applicability; description of the carbon monoxide and by-product hydrogen production subcategory. The provisions...

  8. 40 CFR 415.330 - Applicability; description of the carbon monoxide and by-product hydrogen production subcategory.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... carbon monoxide and by-product hydrogen production subcategory. 415.330 Section 415.330 Protection of... MANUFACTURING POINT SOURCE CATEGORY Carbon Monoxide and By-Product Hydrogen Production Subcategory § 415.330 Applicability; description of the carbon monoxide and by-product hydrogen production subcategory. The provisions...

  9. Composite catalyst for carbon monoxide and hydrocarbon oxidation

    DOEpatents

    Liu, W.; Flytzani-Stephanopoulos, M.

    1996-03-19

    A method and composition are disclosed for the complete oxidation of carbon monoxide and/or hydrocarbon compounds. The method involves reacting the carbon monoxide and/or hydrocarbons with an oxidizing agent in the presence of a metal oxide composite catalyst. The catalyst is prepared by combining fluorite-type oxygen ion conductors with active transition metals. The fluorite oxide, selected from the group consisting of cerium oxide, zirconium oxide, thorium oxide, hafnium oxide, and uranium oxide, and may be doped by alkaline earth and rare earth oxides. The transition metals, selected from the group consisting of molybdenum, copper, cobalt, manganese, nickel, and silver, are used as additives. The atomic ratio of transition metal to fluorite oxide is less than one.

  10. Composite catalyst for carbon monoxide and hydrocarbon oxidation

    DOEpatents

    Liu, Wei; Flytzani-Stephanopoulos, Maria

    1996-01-01

    A method and composition for the complete oxidation of carbon monoxide and/or hydrocarbon compounds. The method involves reacting the carbon monoxide and/or hydrocarbons with an oxidizing agent in the presence of a metal oxide composite catalyst. The catalyst is prepared by combining fluorite-type oxygen ion conductors with active transition metals. The fluorite oxide, selected from the group consisting of cerium oxide, zirconium oxide, thorium oxide, hafnium oxide, and uranium oxide, and may be doped by alkaline earth and rare earth oxides. The transition metals, selected from the group consisting of molybdnum, copper, cobalt, maganese, nickel, and silver, are used as additives. The atomic ratio of transition metal to fluorite oxide is less than one.

  11. A new method for inferring carbon monoxide concentrations from gas filter radiometer data

    NASA Technical Reports Server (NTRS)

    Wallio, H. A.; Reichle, H. G., Jr.; Casas, J. C.; Gormsen, B. B.

    1981-01-01

    A method for inferring carbon monoxide concentrations from gas filter radiometer data is presented. The technique can closely approximate the results of more costly line-by-line radiative transfer calculations over a wide range of altitudes, ground temperatures, and carbon monoxide concentrations. The technique can also be used over a larger range of conditions than those used for the regression analysis. Because the influence of the carbon monoxide mixing ratio requires only addition, multiplication and a minimum of logic, the method can be implemented on very small computers or microprocessors.

  12. Severe carbon monoxide poisoning complicated by hypothermia: a case report.

    PubMed

    Kamijo, Yoshito; Ide, Toshimitsu; Ide, Ayako; Soma, Kazui

    2011-03-01

    It is proposed that the significant elevation of interleukin-6 (>400 pg/mL) in cerebrospinal fluid during the early phase of carbon monoxide poisoning may be a predictive biomarker for the development of delayed encephalopathy. A 52-year-old man presented to the emergency department with severe carbon monoxide poisoning. On arrival, the patient was comatose with decorticate rigidity (Glasgow Coma Scale, E1V1M3). His core body temperature, measured in the urinary bladder, was 32.4°C. Laboratory blood analysis revealed elevated CO-Hb (36.0%) and metabolic acidosis with elevated lactate (pH 7.081; base excess [BE], -19.2 mmol/L; HCO3, -9.8 mmol/L; lactate, 168.8 mg/dL). After treatment with hyperbaric oxygen and several different rewarming techniques, he became alert and his core body temperature increased to normal. Interleukin-6 in cerebrospinal fluid at 5.5 hours after his last exposure to carbon monoxide was significantly elevated (752 pg/mL). However, he did not develop delayed encephalopathy. In this case, hypothermia in the range of therapeutic hypothermia (32°C to 34°C) may have suppressed formation of reactive oxygen species and subsequent lipid peroxydation, preventing the development of delayed encephalopathy. Therapeutic hypothermia initiated soon after the last exposure to carbon monoxide may be an effective prophylactic method for preventing the development of delayed encephalopathy.

  13. 78 FR 48638 - Approval and Promulgation of State Implementation Plans: Alaska; Fairbanks Carbon Monoxide...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-08-09

    ... Promulgation of State Implementation Plans: Alaska; Fairbanks Carbon Monoxide Limited Maintenance Plan AGENCY: Environmental Protection Agency (EPA). ACTION: Proposed rule. SUMMARY: The EPA is proposing to approve a carbon... carbon monoxide National Ambient Air Quality Standards through the second 10- year maintenance period...

  14. Selected constituents in the smokes of foreign commercial cigaretts: tar, nicotine, carbon monoxide, and carbon dioxide

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jenkins, R.A.; Quincy, R.B.; Guerin, M.R.

    The tar, nicotine, carbon monoxide, and carbon dioxide contents of the smokes of 220 brands of foreign commercial cigarettes are reported. In some instances, filter cigarettes of certain brands were found to deliver as much or more smoke constituents than their nonfilter counterparts. Also, data indicated that there can be a great variation in the tar, nicotine, or carbon monoxide content of the smoke of samples of a given brand of cigarettes, depending on the nation in which they are purchased. 24 tables.

  15. [Carboxyhemoglobin concentration in carbon monoxide poisoning. Critical appraisal of the predictive value].

    PubMed

    Köthe, L; Radke, J

    2010-06-01

    In cases of unclear depression of conciousness, arrhythmia and symptoms of cardiac insufficiency inadvertent carbon monoxide intoxication should always be taken into consideration. Rapid diagnosis of acute carbon monoxide intoxication with mostly unspecific symptoms requires an immediate supply of high dose oxygen which enables a distinct reduction of mortality and long-term morbidity. Levels of carboxyhemoglobin, however, should not be used as a parameter to decide whether to supply normobaric or the more efficient hyperbaric oxygen. There is no sufficient coherence between carboxyhemoglobin blood levels and clinical symptoms. Increased carboxyhemoglobin concentrations help to diagnose acute carbon monoxide intoxication but do not allow conclusions to be drawn about possible long-term neuropsychiatric or cardiac consequences.

  16. CRISM Observations of Water Vapor and Carbon Monoxide

    NASA Technical Reports Server (NTRS)

    Smith, Michael D.; Wolff, Michael J.; Clancy, R. Todd

    2008-01-01

    Near-infrared spectra returned by the Compact Reconnaissance Imaging Spectrometer for Mars (CRISM, [1]) on-board the Mars Reconnaissance Orbiter (MRO) contain the clear spectral signature of several atmospheric gases including carbon dioxide (CO2), water vapor (H2O), and carbon monoxide (CO). Here we describe the seasonal and spatial mapping of water vapor and carbon dioxide for one full Martian year using CRISM spectra.

  17. The oxidation of carbon monoxide using tin oxide based catalysts

    NASA Technical Reports Server (NTRS)

    Sampson, Christopher F.; Jorgensen, Norman

    1990-01-01

    The preparation conditions for precious metal/tin oxide catalysts were optimized for maximum carbon monoxide/oxygen recombination efficiency. This was achieved by controlling the tin digestion, the peptization to form the sol, the calcination process and the method of adding the precious metals. Extensive studies of the tin oxide structure were carried out over the temperature range 20 to 500 C in air or hydrogen environments using Raman scattering and X ray diffraction. Adsorbed species on tin oxide, generated in an environment containing carbon monoxide, gave rise to a Raman band at about 1600 cm(exp -1) which was assigned to carbonaceous groups, possible carbonate.

  18. Carbon monoxide toxicity. (Latest citations from the Life Sciences Collection data base). Published Search

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    The bibliography contains citations concerning the mechanism and clinical manifestations of carbon monoxide (CO) exposure, including the effects on the liver, cardiovascular, and nervous systems. Topics include studies of the carbon monoxide binding affinity with hemoglobin, measurement of carboxyhemoglobin in humans and various animal species, carbon monoxide levels resulting from tobacco and marijuana smoke, occupational exposure and the NIOSH (National Institute for Occupational Safety and Health) biological exposure index, symptomology and percent of blood CO, and intrauterine exposure. Air pollution, tobacco smoking, and occupational exposure are discussed as primary sources of carbon monoxide exposure. The effects of cigarette smoking onmore » fetal development and health are excluded and examined in a separate bibliography. (Contains a minimum of 172 citations and includes a subject term index and title list.)« less

  19. Utility of the Measurement of Carboxyhemoglobin Level at the Site of Acute Carbon Monoxide Poisoning in Rural Areas.

    PubMed

    Onodera, Makoto; Fujino, Yasuhisa; Kikuchi, Satoshi; Sato, Masayuki; Mori, Kiyofumi; Beppu, Takaaki; Inoue, Yoshihiro

    2016-01-01

    Objective. This study examined the hypothesis that correlations exist between the carbon monoxide exposure time and the carboxyhemoglobin concentration at the site of carbon monoxide poisoning, using a pulse carbon monoxide oximeter in rural areas or the carboxyhemoglobin concentration measured at a given medical institution. Background. In previous studies, no definitive relationships between the arterial blood carboxyhemoglobin level and the severity of carbon monoxide poisoning have been observed. Method. The subjects included patients treated for acute carbon monoxide poisoning in whom a medical emergency team was able to measure the carboxyhemoglobin level at the site of poisoning. We examined the relationship between the carboxyhemoglobin level at the site of poisoning and carbon monoxide exposure time and the relationships between the arterial blood carboxyhemoglobin level and carbon monoxide exposure time. Results. A total of 10 patients met the above criteria. The carboxyhemoglobin levels at the site of poisoning were significantly and positively correlated with the exposure time (rs = 0.710, p = 0.021), but the arterial blood carboxyhemoglobin levels were not correlated with the exposure time. Conclusion. In rural areas, the carboxyhemoglobin level measured at the site of carbon monoxide poisoning correlated with the exposure time.

  20. 49 CFR 392.66 - Carbon monoxide; use of commercial motor vehicle when detected.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 5 2011-10-01 2011-10-01 false Carbon monoxide; use of commercial motor vehicle... SAFETY REGULATIONS DRIVING OF COMMERCIAL MOTOR VEHICLES Prohibited Practices § 392.66 Carbon monoxide; use of commercial motor vehicle when detected. (a) No person shall dispatch or drive any commercial...

  1. An Unusual Cause of Carbon Monoxide Poisoning: Narghile Smoking

    PubMed Central

    Ateş, Alpay; Arikan, Müge; Özgök, Ayşegül

    2016-01-01

    Patient: Male, 27 Final Diagnosis: Carbon monoxide poisoning Symptoms: Dizziness • nausea • Syncope Medication: — Clinical Procedure: O2 treatment Specialty: Anesthesiology Objective: Challenging differential diagnosis Background: Carbon monoxide (CO) poisoning is commonly seen during the winter season in Turkey due to use of charcoal stoves and water heaters, but narghile smoking is a rare cause of CO poisoning. Case Report: In this paper, we report a CO poisoning case caused by narghile smoking. The patient was admitted to the ED with nausea, dizziness, vertigo, and syncope. Conclusions: The diagnosis of CO poisoning depends on suspicious anamnesis. The major treatment of CO poisoning is oxygen supply. PMID:27618983

  2. Carbon monoxide poisoning-induced cardiomyopathy from charcoal at a barbecue restaurant: a case report.

    PubMed

    Kim, Hyun-Jun; Chung, Yun Kyung; Kwak, Kyeong Min; Ahn, Se-Jin; Kim, Yong-Hyun; Ju, Young-Su; Kwon, Young-Jun; Kim, Eun-A

    2015-01-01

    Acute carbon monoxide poisoning has important clinical value because it can cause severe adverse cardiovascular effects and sudden death. Acute carbon monoxide poisoning due to charcoal is well reported worldwide, and increased use of charcoal in the restaurant industry raises concern for an increase in occupational health problems. We present a case of carbon monoxide poisoning induced cardiomyopathy in a 47-year-old restaurant worker. A male patient was brought to the emergency department to syncope and complained of left chest pain. Cardiac angiography and electrocardiography were performed to rule out acute ischemic heart disease, and cardiac markers were checked. After relief of the symptoms and stabilization of the cardiac markers, the patient was discharged without any complications. Electrocardiography was normal, but cardiac angiography showed up to a 40% midsegmental stenosis of the right coronary artery with thrombotic plaque. The level of cardiac markers was elevated at least 5 to 10 times higher than the normal value, and the carboxyhemoglobin concentration was 35% measured at one hour after syncope. Following the diagnosis of acute carbon monoxide poisoning induced cardiomyopathy, the patient's medical history and work exposure history were examined. He was found to have been exposed to burning charcoal constantly during his work hours. Severe exposure to carbon monoxide was evident in the patient because of high carboxyhemoglobin concentration and highly elevated cardiac enzymes. We concluded that this exposure led to subsequent cardiac injury. He was diagnosed with acute carbon monoxide poisoning-induced cardiomyopathy due to an unsafe working environment. According to the results, the risk of exposure to noxious chemicals such as carbon monoxide by workers in the food service industry is potentially high, and workers in this sector should be educated and monitored by the occupational health service to prevent adverse effects.

  3. CARBON MONOXIDE POISONING--A PUBLIC HEALTH PERSPECTIVE.

    EPA Science Inventory

    Carbon monoxide (CO) may be the cause of more than one-half of the fatal poisonings reported in many countries: fatal cases also are grossly under-reported or mis-diagnosed by medical professionals. Therefore, the precise number of individuals who have suffered from CO intoxicat...

  4. 40 CFR 91.317 - Carbon monoxide analyzer calibration.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... service and annually thereafter, check the NDIR carbon monoxide analyzer for response to water vapor and... N2 through water at room temperature and record analyzer response. (4) An analyzer response of more...

  5. 40 CFR 91.317 - Carbon monoxide analyzer calibration.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... service and annually thereafter, check the NDIR carbon monoxide analyzer for response to water vapor and... N2 through water at room temperature and record analyzer response. (4) An analyzer response of more...

  6. 40 CFR 91.317 - Carbon monoxide analyzer calibration.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... service and annually thereafter, check the NDIR carbon monoxide analyzer for response to water vapor and... N2 through water at room temperature and record analyzer response. (4) An analyzer response of more...

  7. 40 CFR 91.317 - Carbon monoxide analyzer calibration.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... service and annually thereafter, check the NDIR carbon monoxide analyzer for response to water vapor and... N2 through water at room temperature and record analyzer response. (4) An analyzer response of more...

  8. Development of a breadboard model correlation interferometer for the carbon monoxide pollution experiment

    NASA Technical Reports Server (NTRS)

    Bortner, M. H.; Dick, R.; Goldstein, H. W.; Grenda, R. N.; Levy, G. M.

    1973-01-01

    The breadboard model of the correlation interferometer for the Carbon Monoxide Pollution Experiment has been designed, fabricated, and tested. Laboratory, long-path, and atmospheric tests which were performed show the technique to be a feasible method for obtaining a global carbon monoxide map and a vertical carbon monoxide profile and similar information is readily obtainable for methane as well. In addition, the technique is readily applicable to other trace gases by minor instrumental changes. As shown by the results and the conclusions, it has been determined that CO and CH4 data can be obtained with an accuracy of 10% using this technique on the spectral region around 2.3 microns.

  9. Environmental variables and levels of exhaled carbon monoxide and carboxyhemoglobin in elderly people taking exercise.

    PubMed

    Salicio, Marcos Adriano; Mana, Viviane Aparecida Martins; Fett, Waléria Christiane Rezende; Gomes, Luciano Teixeira; Botelho, Clovis

    2016-04-01

    This article aims to analyze levels of exhaled carbon monoxide, carboxyhemoglobinand cardiopulmonary variables in old people practicing exercise in external environments, and correlate them with climate and pollution factors. Temporal ecological study with118 active elderly people in the city of Cuiabá, in the state of Mato Grosso, Brazil. Data were obtained on use of medication, smoking, anthropometric measurements, spirometry, peak flow, oxygen saturation, heart rate, exhaled carbon monoxide, carboxyhemoglobin, climate, number of farm fires and pollution. Correlations were found between on the one hand environmental temperature, relative humidity of the air and number of farmers' fires, and on the other hand levels of carbon monoxide exhaled and carboxyhemoglobin (p < 0.05).There was a correlation between heart rate and changes in environmental temperature, time of exposure to the sun and relative humidity (p < 0.05). In elderly people, environmental factors influence levels of exhaled carbon monoxide, carboxyhemoglobin and heart rate. There is thus a need for these to be monitored during exercise. The use of a carbon monoxide monitor to evaluate exposure to pollutants is suggested.

  10. Airborne Observations of Enhanced Marine Boundary Layer Carbon Monoxide over Remote Tropical Oceans

    NASA Astrophysics Data System (ADS)

    Campos, T. L.; Stell, M. H.; Apel, E. C.; Hornbrook, R. S.; Hills, A. J.; Weinheimer, A. J.; Montzka, D.; Kaser, L.; Aquino, J.

    2014-12-01

    Recent airborne observations of tropical marine boundary layer carbon monoxide included several instances of elevated MBL CO with a notable absence of corresponding enhancements in ozone. Instances were observed during the recent CONTRAST exploration of tropical Pacific marine dynamics and composition. The lack of correlation between sampled carbon monoxide and ozone is consistent with an oceanic source of CO. Carbon monoxide vertical flux will be estimated for all CONTRAST boundary layer transects, with particular focus on these events. Complementary correlative observations of trace organics lend insight into processes defining this composition. The frequency of occurrence will be presented along with comparison to similar observations within other data sets, including TORERO (2012), and HIPPO (2009-2012).

  11. Carbon monoxide in breath in relation to smoking and carboxyhaemoglobin levels.

    PubMed Central

    Wald, N J; Idle, M; Boreham, J; Bailey, A

    1981-01-01

    Carboxyhaemoglobin (COHb) levels were studied in 11 249 men. The distribution among the 2613 men who smoked cigarettes was well separated from that in 6641 non-smokers (including ex-smokers). The distribution for 2005 cigar and pipe smokers was intermediate, though some of the highest COHb levels occurred in cigar smokers. Using a COHb cut-off level of 2%, 81% of cigarette smokers, 35% of cigar and pipe smokers, and 1.0% of non-smokers had raised COHb levels. In a subsidiary experiment alveolar air samples were collected from 162 smokers and 25 non-smokers using a simple breath sampling technique. Carbon monoxide concentrations in alveolar breath were highly correlated with COHb levels (r = 0.97) indicating that COHb levels can be estimated reliably by measuring the concentration of carbon monoxide in breath. Alveolar carbon monoxide measurement is thus a simple method of estimating whether a person is likely to be a smoker. PMID:7314006

  12. Inhalation Toxicology. X., Times to incapacitation for rats exposed continuously to carbon monoxide, acrolein, and to carbon monoxide-acrolein mixtures.

    DOT National Transportation Integrated Search

    1990-12-01

    Laboratory rats were exposed to experimental atmospheres of (a) carbon monoxide (CO) in air, (b) acrolein in air, and (c) to mixtures of CO and acrolein in air. The toxic potency of each of the three types of environments was evaluated toxicokinetica...

  13. Vibrationally Excited Carbon Monoxide Produced via a Chemical Reaction Between Carbon Vapor and Oxygen

    NASA Astrophysics Data System (ADS)

    Jans, Elijah R.; Eckert, Zakari; Frederickson, Kraig; Rich, Bill; Adamovich, Igor V.

    2017-06-01

    Measurements of the vibrational distribution function of carbon monoxide produced via a reaction between carbon vapor and molecular oxygen has shown a total population inversion on vibrational levels 4-7. Carbon vapor, produced using an arc discharge to sublimate graphite, is mixed with an argon oxygen flow. The excited carbon monoxide is vibrationally populated up to level v=14, at low temperatures, T=400-450 K, in a collision-dominated environment, 15-20 Torr, with total population inversions between v=4-7. The average vibrational energy per CO molecule formed by the reaction is 0.6-1.2 eV/molecule, which corresponds to 10-20% of the reaction enthalpy. Kinetic modeling of the flow reactor, including state specific vibrational processes, was performed to infer the vibrational distribution of the products of the reaction. The results show viability of developing of a new chemical CO laser from the reaction of carbon vapor and oxygen.

  14. Effect of carbon monoxide on plants. [Mimosa pudica

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zimmerman, P.W.; Crocker, W.; Hitchcock, A.E.

    Of 108 species of plants treated with one per cent carbon monoxide, 45 showed epinastic growth of leaves. Several species showed hyponasty which caused upward curling of leaves. Other effects included: retarded stem elongation; abnormally small new leaves; abnormal yellowing of the leaves, beginning with the oldest; abscission of leaves usually associated with yellowing; and hypertrophied tissues on stems and roots. During recovery an abnormally large number of side shoots arose from latent buds of many species. Motion pictures of Mimosa pudica showed a loss of correlation, normal equilibrium position to gravity, and sensitiveness to contact or heat stimuli; however,more » the leaves moved about more rapidly than those of controls. Since carbon monoxide causes growth rigor and loss of sensitiveness to external stimuli, it is here considered as an anesthetic.« less

  15. Assessment of carbon monoxide values in smokers: a comparison of carbon monoxide in expired air and carboxyhaemoglobin in arterial blood.

    PubMed

    Andersson, Mette F; Møller, Ann M

    2010-09-01

    Smoking increases perioperative complications. Carbon monoxide concentrations can estimate patients' smoking status and might be relevant in preoperative risk assessment. In smokers, we compared measurements of carbon monoxide in expired air (COexp) with measurements of carboxyhaemoglobin (COHb) in arterial blood. The objectives were to determine the level of correlation and to determine whether the methods showed agreement and evaluate them as diagnostic tests in discriminating between heavy and light smokers. The study population consisted of 37 patients. The Micro Smokerlyzer was used to measure COexp; it measures COexp in parts per million (ppm) and converts it to the percentage of haemoglobin combined with carbon monoxide (%Hb). COHb in arterial blood was measured by the ABL 725. Correlation analysis and Bland-Altman analysis were performed, and 2 x 2 contingency tables and receiver operating characteristic curve analysis were conducted. The correlation between the methods was high (rho = 0.964). Bland-Altman analysis demonstrated that the Micro Smokerlyzer underestimated COHb values. The areas under the receiver operating characteristic curves were 0.746 (ABL 725) and 0.754 (Micro Smokerlyzer) and, by comparison, no statistically significant difference was found (P = 0.815). The two methods showed a high level of correlation, but poor agreement. The Micro Smokerlyzer systematically underestimated COHb values and, in order to avoid this, we suggested an alternative algorithm for converting COexp from ppm to %Hb. The ABL 725 and Micro Smokerlyzer were fair diagnostic tests in distinguishing between heavy and light smokers, but the longer the patients' smoking cessation time, the poorer the ability as diagnostic tests.

  16. Carbon monoxide-induced suspended animation protects against hypoxic damage in Caenorhabditis elegans

    PubMed Central

    Nystul, Todd G.; Roth, Mark B.

    2004-01-01

    Oxygen deprivation is a major cause of cellular damage and death. Here we demonstrate that Caenorhabditis elegans embryos, which can survive both in anoxia (<0.001 kPa O2) by entering into suspended animation and in mild hypoxia (0.25-1 kPa O2) through a hypoxia-inducible factor 1-mediated response, cannot survive in intermediate concentrations of oxygen, between 0.01 and 0.1 kPa O2. Moreover, we show that carbon monoxide can protect C. elegans embryos against hypoxic damage in this sensitive range. Carbon monoxide can also rescue the hypoxia-sensitive mutant hif-1(ia04) from lethality in hypoxia. This work defines the oxygen tensions over which hypoxic damage occurs in C. elegans embryos and demonstrates that carbon monoxide can prevent this damage by inducing suspended animation. PMID:15184665

  17. Correlation of computed tomography, magnetic resonance imaging and clinical outcome in acute carbon monoxide poisoning.

    PubMed

    Ozcan, Namik; Ozcam, Giray; Kosar, Pinar; Ozcan, Ayse; Basar, Hulya; Kaymak, Cetin

    2016-01-01

    Carbon monoxide is a toxic gas for humans and is still a silent killer in both developed and developing countries. The aim of this case series was to evaluate early radiological images as a predictor of subsequent neuropsychological sequelae, following carbon monoxide poisoning. After carbon monoxide exposure, early computed tomography scans and magnetic resonance imaging findings of a 52-year-old woman showed bilateral lesions in the globus pallidus. This patient was discharged and followed for 90 days. The patient recovered without any neurological sequela. In a 58-year-old woman exposed to carbon monoxide, computed tomography showed lesions in bilateral globus pallidus and periventricular white matter. Early magnetic resonance imaging revealed changes similar to that like in early tomography images. The patient recovered and was discharged from hospital. On the 27th day of exposure, the patient developed disorientation and memory impairment. Late magnetic resonance imaging showed diffuse hyperintensity in the cerebral white matter. White matter lesions which progress to demyelination and end up in neuropsychological sequelae cannot always be diagnosed by early computed tomography and magnetic resonance imaging in carbon monoxide poisoning. Copyright © 2014 Sociedade Brasileira de Anestesiologia. Published by Elsevier Editora Ltda. All rights reserved.

  18. Photoproduction of Carbon Monoxide from Natural Organic Matter

    EPA Science Inventory

    Pioneering studies by Valentine provided early kinetic results that used carbon monoxide (CO) production to evaluate the photodecomposition of aquatic natural organic matter (NOM) . (ES&T 1993 27 409-412). Comparatively few kinetic studies have been conducted of the photodegradat...

  19. Measuring Carbon Monoxide in Auto Exhaust by Gas Chromatography.

    ERIC Educational Resources Information Center

    Jaffe, Dan; Herndon, Scott

    1995-01-01

    Presents a simple and reliable technique using commonly available equipment for monitoring carbon monoxide in automobile exhaust. The experiment utilizes a gas chromatograph and a thermal conductivity detector (TCD). (DDR)

  20. Non-convulsive status epilepticus in a patient with carbon-monoxide poisoning treated with hyperbaric oxygen therapy.

    PubMed

    Marziali, Simone; Di Giuliano, Francesca; Picchi, Eliseo; Natoli, Silvia; Leonardis, Carlo; Leonardis, Francesca; Garaci, Francesco; Floris, Roberto

    2016-12-01

    The presentation of carbon monoxide poisoning is non-specific and highly variable. Hyperbaric oxygen therapy is used for the treatment of this condition. Various reports show the occurrence of self-limiting seizures after carbon monoxide poisoning and as a consequence of hyperbaric oxygen therapy. Contrary to the seizures, status epilepticus has been rarely observed in these conditions. The exact pathophysiology underlying seizures and status epilepticus associated with carbon monoxide poisoning and hyperbaric oxygen therapy is not really clear, and some elements appear to be common to both conditions. We describe a case of non-convulsive status epilepticus in a patient with carbon monoxide poisoning treated with hyperbaric oxygen therapy. The mechanism, MRI findings and implications are discussed. © The Author(s) 2016.

  1. A Fire Department Community Health Intervention to Prevent Carbon Monoxide Poisoning Following a Hurricane

    PubMed Central

    Levy, Matthew; Jenkins, J Lee; Seaman, Kevin

    2014-01-01

    Portable generators are commonly used during electrical service interruptions that occur following large storms such as hurricanes. Nearly all portable generators use carbon based fuels and produce deadly carbon monoxide gas. Despite universal warnings to operate these generators outside only, the improper placement of generators makes these devices the leading cause of engine related carbon monoxide deaths in the United States. The medical literature reports many cases of Carbon Monoxide (CO) toxicity associated with generator use following hurricanes and other weather events. This paper describes how Howard County, Maryland Fire and Rescue (HCFR) Services implemented a public education program that focused on prevention of Carbon Monoxide poisoning from portable generator use in the wake of events where electrical service interruptions occurred or had the potential to occur. A major challenge faced was communication with those members of the population who were almost completely dependent upon electronic and wireless technologies and were without redundancies. HCFR utilized several tactics to overcome this challenge including helicopter based surveillance and the use of geocoded information from the electrical service provider to identify outage areas. Once outage areas were identified, HCFR personnel conducted a door-to-door canvasing of effected communities, assessing for hazards and distributing information flyers about the dangers of generator use. This effort represents one of the first reported examples of a community-based endeavor by a fire department to provide proactive interventions designed to prevent carbon monoxide illness. PMID:24596660

  2. Tar, nicotine, and carbon monoxide yields of some Nigerian cigarettes.

    PubMed Central

    Awotedu, A A; Higenbottam, T W; Onadeko, B O

    1983-01-01

    Fourteen cigarette brands manufactured in Nigeria in 1981 were analysed to determine the tar, nicotine, and carbon monoxide yields. Five of the brands belonged to the high and middle to high tar category (greater than 22 mg/cigarette) and nine to the middle tar (17-22 mg/cigarette) category. None of the cigarettes was in the low to middle and low tar (less than 17 mg/cigarette) category. The nicotine and carbon monoxide yields were similar to those of European cigarettes. Tobacco companies need to manufacture low tar cigarettes in the Third World as is the practice in the economically developed parts of the world. PMID:6619721

  3. AIR QUALITY CRITERIA CARBON MONOXIDE, EXTERNAL REVIEW DRAFT

    EPA Science Inventory

    The U.S. Environmental Protection Agency (EPA) promulgates the National Ambient Air Quality Standards (NAAQS) on the basis of scientific information contained in criteria documents. The last air quality criteria document for carbon monoxide (CO) was completed by EPA in 1991. This...

  4. Carbon Monoxide Exposure in Youth Ice Hockey.

    PubMed

    Macnow, Theodore; Mannix, Rebekah; Meehan, William P

    2017-11-01

    To examine the effect of ice resurfacer type on carboxyhemoglobin levels in youth hockey players. We hypothesized that players in arenas with electric resurfacers would have normal, stable carboxyhemoglobin levels during games, whereas those in arenas with internal combustion engine (IC) resurfacers would have an increase in carboxyhemoglobin levels. Prospective cohort study. Enclosed ice arenas in the northeastern United States. Convenience sample of players aged 8 to 18 years old in 16 games at different arenas. Eight arenas (37 players) used an IC ice resurfacer and 8 arenas (36 players) an electric resurfacer. Carboxyhemoglobin levels (SpCO) were measured using a pulse CO-oximeter before and after the game. Arena air was tested for carbon monoxide (CO) using a metered gas detector. Players completed symptom questionnaires. The change in SpCO from pregame to postgame was compared between players at arenas with electric versus IC resurfacers. Carbon monoxide was present at 6 of 8 arenas using IC resurfacers, levels ranged from 4 to 42 parts per million. Carbon monoxide was not found at arenas with electric resurfacers. Players at arenas with IC resurfacers had higher median pregame SpCO levels compared with those at electric arenas (4.3% vs 1%, P < 0.01). Players in the IC group also had a significant increase in their SpCO level during a hockey game compared with those in the electric group (2.8% vs 1%, P = 0.01). There were no significant differences in symptom scores. Players at arenas operating IC resurfacers had significantly higher SpCO levels. Youth hockey players in arenas with IC resurfacers have an increase in carboxyhemoglobin during games and have elevated baseline carboxyhemoglobin levels compared with players at arenas with electric resurfacers. Electric resurfacers decrease the risk of CO exposure.

  5. Carbon Monoxide Improves Efficacy of Mesenchymal Stromal Cells During Sepsis by Production of Specialized Proresolving Lipid Mediators.

    PubMed

    Tsoyi, Konstantin; Hall, Sean R R; Dalli, Jesmond; Colas, Romain A; Ghanta, Sailaja; Ith, Bonna; Coronata, Anna; Fredenburgh, Laura E; Baron, Rebecca M; Choi, Augustine M K; Serhan, Charles N; Liu, Xiaoli; Perrella, Mark A

    2016-12-01

    Mesenchymal stromal cells are being investigated as a cell-based therapy for a number of disease processes, with promising results in animal models of systemic inflammation and sepsis. Studies are ongoing to determine ways to further improve the therapeutic potential of mesenchymal stromal cells. A gas molecule that improves outcome in experimental sepsis is carbon monoxide. We hypothesized that preconditioning of mesenchymal stromal cells with carbon monoxide ex vivo would promote further therapeutic benefit when cells are administered in vivo after the onset of polymicrobial sepsis in mice. Animal study and primary cell culture. Laboratory investigation. BALB/c mice. Polymicrobial sepsis was induced by cecal ligation and puncture. Mesenchymal stromal cells, mesenchymal stromal cells-conditioned with carbon monoxide, fibroblasts, or fibroblasts-conditioned with carbon monoxide were delivered by tail vein injections to septic mice. The mice were assessed for survival, bacterial clearance, and the inflammatory response during sepsis in each of the groups. Mesenchymal stromal cells were also assessed for their ability to promote bacterial phagocytosis by neutrophils, the production of specialized proresolving lipid mediators, and their importance for mesenchymal stromal cells function using gene silencing. Ex vivo preconditioning with carbon monoxide allowed mesenchymal stromal cells to be administered later after the onset of sepsis (6 hr), and yet maintain their therapeutic effect with increased survival. Carbon monoxide preconditioned mesenchymal stromal cells were also able to alleviate organ injury, improve bacterial clearance, and promote the resolution of inflammation. Mesenchymal stromal cells exposed to carbon monoxide, with docosahexaenoic acid substrate, produced specialized proresolving lipid mediators, particularly D-series resolvins, which promoted survival. Silencing of lipoxygenase pathways (5-lipoxygenase and 12/15-lipoxygenase), which are

  6. 40 CFR 52.2353 - Control strategy: Carbon monoxide.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 5 2012-07-01 2012-07-01 false Control strategy: Carbon monoxide. 52.2353 Section 52.2353 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS (CONTINUED) Utah § 52.2353 Control strategy...

  7. 40 CFR 52.1340 - Control strategy: Carbon monoxide.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 4 2011-07-01 2011-07-01 false Control strategy: Carbon monoxide. 52.1340 Section 52.1340 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS (CONTINUED) Missouri § 52.1340 Control strategy...

  8. 40 CFR 52.1340 - Control strategy: Carbon monoxide.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 4 2012-07-01 2012-07-01 false Control strategy: Carbon monoxide. 52.1340 Section 52.1340 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS (CONTINUED) Missouri § 52.1340 Control strategy...

  9. 40 CFR 52.2353 - Control strategy: Carbon monoxide.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 4 2011-07-01 2011-07-01 false Control strategy: Carbon monoxide. 52.2353 Section 52.2353 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS (CONTINUED) Utah § 52.2353 Control strategy...

  10. Production of Ethylene and Carbon Monoxide by Microorganisms

    Treesearch

    T. H. Filer; L. R. Brown; S. Brown-Sarobot; S. Martin

    1984-01-01

    Various quantities of ethylene and carbon monoxide were produced on PDA by Fusicladium effusum, Pestilotia nucicola, Alternaria tenuis, and Fusarium oxysporum subcultured from diseased pecan shucks. Repeated subculturing of these fungi on potato dextrose broth supplemented with iron powder produced ethylene. The production of...

  11. Cardiological aspects of carbon monoxide poisoning.

    PubMed

    Marchewka, Jakub; Gawlik, Iwona; Dębski, Grzegorz; Popiołek, Lech; Marchewka, Wojciech; Hydzik, Piotr

    2017-01-01

    The aim of this study was to assess cardiological manifestations of carbon monoxide (CO) poisoning. Background/introduction: Carbon monoxide intoxication is one of the most important toxicological causes of morbidity and mortality worldwide. Early clinical manifestation of CO poisoning is cardiotoxicity. We enrolled 75 patients (34 males and 41 females, mean age 37.6 ± 17.7 y/o) hospitalized due to CO poisoning. Laboratory tests including troponin I, blood pressure measurements, HR and electrocardiograms (ECG) were collected. Pach's scale scoring and grading system was used to establish severity of poisoning. Grade of poisoning is positively correlated with troponin I levels and systolic blood pressure. Moreover, troponin levels are significantly correlated with exposition time, lactates and are higher in tachycardiac, hypertensive and positive ECG subpopulations. COHb levels are indicative of exposure but do not correlate with grade of poisoning. The main cause of CO poisoning were bathroom heaters - 83%, only 11% of examined intoxicated population were equipped with CO detectors. Complex cardiological screening covering troponin levels, ECG, blood pressure and heart rate measurements as well as complete blood count with particular attention to platelet parameters should be performed in each case where CO intoxication is suspected. More emphasis on education on CO poisoning is needed.

  12. 75 FR 54805 - Approval and Promulgation of Air Quality Implementation Plans; Minnesota; Carbon Monoxide (CO...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-09-09

    ... Promulgation of Air Quality Implementation Plans; Minnesota; Carbon Monoxide (CO) Limited Maintenance Plan for... June 16, 2010, to revise the Minnesota State Implementation Plan (SIP) for carbon monoxide (CO) under the Clean Air Act (CAA). The State has submitted a limited maintenance plan for CO showing continued...

  13. 40 CFR 89.320 - Carbon monoxide analyzer calibration.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... introduction into service and annually thereafter, the NDIR carbon monoxide analyzer shall be checked for... to its introduction into service, after any maintenance which could alter calibration, and every two... engineering practice. For each range calibrated, if the deviation from a least-squares best-fit straight line...

  14. Catalyst for the methanation of carbon monoxide in sour gas

    DOEpatents

    Kustes, William A.; Hausberger, Arthur L.

    1985-01-01

    The invention involves the synergistic effect of the specific catalytic constituents on a specific series of carriers for the methanation of carbon monoxide in the presence of sulfur at relatively high temperatures and at low steam to gas ratios in the range of 0.2:1 or less. This effect was obtained with catalysts comprising the mixed sulfides and oxides of nickel and chromium supported on carriers comprising magnesium aluminate and magnesium silicate. Conversion of carbon monoxide to methane was in the range of from 40 to 80%. Tests of this combination of metal oxides and sulfides on other carriers and tests of other metal oxides and sulfides on the same carrier produced a much lower level of conversion.

  15. Ambient carbon monoxide and cardiovascular mortality: a nationwide time-series analysis in 272 cities in China.

    PubMed

    Liu, Cong; Yin, Peng; Chen, Renjie; Meng, Xia; Wang, Lijun; Niu, Yue; Lin, Zhijing; Liu, Yunning; Liu, Jiangmei; Qi, Jinlei; You, Jinling; Kan, Haidong; Zhou, Maigeng

    2018-01-01

    Evidence of the acute health effects of ambient carbon monoxide air pollution in developing countries is scarce and mixed. We aimed to evaluate short-term associations between carbon monoxide and daily cardiovascular disease mortality in China. We did a nationwide time-series analysis in 272 major cities in China from January, 2013, to December, 2015. We extracted daily cardiovascular disease mortality data from China's Disease Surveillance Points system. Data on daily carbon monoxide concentrations for each city were obtained from the National Urban Air Quality Real-time Publishing Platform. City-specific associations between carbon monoxide concentrations and daily mortality from cardiovascular disease, coronary heart disease, and stroke were estimated with over-dispersed generalised linear models. Bayesian hierarchical models were used to obtain national and regional average associations. Exposure-response association curves and potential effect modifiers were evaluated. Two-pollutant models were fit to evaluate the robustness of the effects of carbon monoxide on cardiovascular mortality. The average annual mean carbon monoxide concentration in these cities from 2013 to 2015 was 1·20 mg/m 3 , ranging from 0·43 mg/m 3 to 2·45 mg/m 3 . For a 1 mg/m 3 increase in average carbon monoxide concentrations on the present day and previous day (lag 0-1), we observed significant increments in mortality of 1·12% (95% posterior interval [PI] 0·42-1·83) from cardiovascular disease, 1·75% (0·85-2·66) from coronary heart disease, and 0·88% (0·07-1·69) from stroke. These associations did not vary substantially by city, region, and demographic characteristics (age, sex, and level of education), and the associations for cardiovascular disease and coronary heart disease were robust to the adjustment of criteria co-pollutants. We did not find a threshold below which carbon monoxide exposure had no effect on cardiovascular disease mortality. This analysis is, to our

  16. Detection of Carbon Monoxide Using Polymer-Carbon Composite Films

    NASA Technical Reports Server (NTRS)

    Homer, Margie L.; Ryan, Margaret A.; Lara, Liana M.

    2011-01-01

    A carbon monoxide (CO) sensor was developed that can be incorporated into an existing sensing array architecture. The CO sensor is a low-power chemiresistor that operates at room temperature, and the sensor fabrication techniques are compatible with ceramic substrates. Sensors made from four different polymers were tested: poly (4-vinylpryridine), ethylene-propylene-diene-terpolymer, polyepichlorohydrin, and polyethylene oxide (PEO). The carbon black used for the composite films was Black Pearls 2000, a furnace black made by the Cabot Corporation. Polymers and carbon black were used as received. In fact, only two of these sensors showed a good response to CO. The poly (4-vinylpryridine) sensor is noisy, but it does respond to the CO above 200 ppm. The polyepichlorohydrin sensor is less noisy and shows good response down to 100 ppm.

  17. Treatment in carbon monoxide poisoning patients with headache: a prospective, multicenter, double-blind, controlled clinical trial.

    PubMed

    Ocak, Tarik; Tekin, Erdal; Basturk, Mustafa; Duran, Arif; Serinken, Mustafa; Emet, Mucahit

    2016-11-01

    There is a lack of specificity of the analgesic agents used to treat headache and underlying acute carbon monoxide poisoning. To compare effectiveness of "oxygen alone" vs "metoclopramide plus oxygen" vs "metamizole plus oxygen" therapy in treating carbon monoxide-induced headache. A prospective, multicenter, double-blind, controlled trial. Three emergency departments in Turkey. Adult carbon monoxide poisoning patients with headache. A total of 117 carbon monoxide-intoxicated patients with headache were randomized into 3 groups and assessed at baseline, 30 minutes, 90 minutes, and 4 hours. The primary outcome was patient-reported improvement rates for headache. Secondary end points included nausea, need for rescue medication during treatment, and reduction in carboxyhemoglobin levels. During observation, there was no statistical difference between drug type and visual analog scale score change at 30 minutes, 90 minutes, or 4 hours, for either headache or nausea. No rescue medication was needed during the study period. The reduction in carboxyhemoglobin levels did not differ among the 3 groups. The use of "oxygen alone" is as efficacious as "oxygen plus metoclopramide" or "oxygen plus metamizole sodium" in the treatment of carbon monoxide-induced headache. Copyright © 2016 Elsevier Inc. All rights reserved.

  18. Hyperbaric Oxygen Therapy Alleviates Carbon Monoxide Poisoning-Induced Delayed Memory Impairment by Preserving Brain-Derived Neurotrophic Factor-Dependent Hippocampal Neurogenesis.

    PubMed

    Liu, Wen-Chung; Yang, San-Nan; Wu, Chih-Wei J; Chen, Lee-Wei; Chan, Julie Y H

    2016-01-01

    To test the hypothesis that hyperbaric oxygen therapy ameliorates delayed cognitive impairment after acute carbon monoxide poisoning by promoting neurogenesis through upregulating the brain-derived neurotrophic factor in the hippocampus. Laboratory animal experiments. University/Medical center research laboratory. Adult, male Sprague-Dawley rats. Rats were divided into five groups: (1) non-carbon monoxide-treated control, (2) acute carbon monoxide poisoning, (3) acute carbon monoxide poisoning followed by 7-day hyperbaric oxygen treatment, (4) carbon monoxide + hyperbaric oxygen with additional intracerebroventricular infusion of Fc fragment of tyrosine kinase receptor B protein (TrkB-Fc) chimera, and (5) acute carbon monoxide poisoning followed by intracerebroventricular infusion of brain-derived neurotrophic factor. Acute carbon monoxide poisoning was achieved by exposing the rats to carbon monoxide at 2,500 ppm for 40 minutes, followed by 3,000 ppm for 20 minutes. Hyperbaric oxygen therapy (at 2.5 atmospheres absolute with 100% oxygen for 60 min) was conducted during the first 7 days after carbon monoxide poisoning. Recombinant human TrkB-Fc chimera or brain-derived neurotrophic factor was infused into the lateral ventricle via the implanted osmotic minipump. For labeling of mitotic cells in the hippocampus, bromodeoxyuridine was injected into the peritoneal cavity. Distribution of bromodeoxyuridine and two additional adult neurogenesis markers, Ki-67 and doublecortin, in the hippocampus was evaluated by immunohistochemistry or immunofluorescence staining. Tissue level of brain-derived neurotrophic factor was assessed by enzyme-linked immunosorbent assay. Cognitive behavior was evaluated by the use of eight-arm radial maze. Acute carbon monoxide poisoning significantly suppressed adult hippocampal neurogenesis evident by the reduction in number of bromodeoxyuridine-positive, Ki-67⁺, and doublecortin⁺ cells in the subgranular zone of the dentate gyrus. This

  19. 40 CFR 60.103 - Standard for carbon monoxide.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Refineries § 60.103 Standard for carbon monoxide. Each owner or operator of any fluid catalytic cracking unit... the fluid catalytic cracking unit catalyst regenerator will be operated, or 180 days after initial... discharge or cause the discharge into the atmosphere from any fluid catalytic cracking unit catalyst...

  20. 40 CFR 60.103 - Standard for carbon monoxide.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Refineries § 60.103 Standard for carbon monoxide. Each owner or operator of any fluid catalytic cracking unit... the fluid catalytic cracking unit catalyst regenerator will be operated, or 180 days after initial... discharge or cause the discharge into the atmosphere from any fluid catalytic cracking unit catalyst...

  1. 21 CFR 862.3220 - Carbon monoxide test system.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Carbon monoxide test system. 862.3220 Section 862.3220 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CLINICAL CHEMISTRY AND CLINICAL TOXICOLOGY DEVICES Clinical Toxicology Test Systems § 862...

  2. 21 CFR 862.3220 - Carbon monoxide test system.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Carbon monoxide test system. 862.3220 Section 862.3220 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CLINICAL CHEMISTRY AND CLINICAL TOXICOLOGY DEVICES Clinical Toxicology Test Systems § 862...

  3. 21 CFR 862.3220 - Carbon monoxide test system.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Carbon monoxide test system. 862.3220 Section 862.3220 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CLINICAL CHEMISTRY AND CLINICAL TOXICOLOGY DEVICES Clinical Toxicology Test Systems § 862...

  4. 21 CFR 862.3220 - Carbon monoxide test system.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Carbon monoxide test system. 862.3220 Section 862.3220 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CLINICAL CHEMISTRY AND CLINICAL TOXICOLOGY DEVICES Clinical Toxicology Test Systems § 862...

  5. Ethylene and Carbon Monoxide Production by Septoria musiva

    Treesearch

    S. Brown-Skrobot; L. R. Brown; T. H. Filer

    1984-01-01

    An investigation into the mechanism by which Septoria musiva causes the premature defoliation of cottonwood trees was undertaken. Gas-chromatograpic analysis of the atmosphere overlying the original culture indicated that this fungus produced significant quantities of ethylene and carbon monoxide. Subcultures failed to produce either gas on a variety...

  6. 40 CFR 89.112 - Oxides of nitrogen, carbon monoxide, hydrocarbon, and particulate matter exhaust emission standards.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ..., hydrocarbon, and particulate matter exhaust emission standards. 89.112 Section 89.112 Protection of....112 Oxides of nitrogen, carbon monoxide, hydrocarbon, and particulate matter exhaust emission... emissions of oxides of nitrogen, carbon monoxide, hydrocarbon, and nonmethane hydrocarbon are measured using...

  7. 40 CFR 89.112 - Oxides of nitrogen, carbon monoxide, hydrocarbon, and particulate matter exhaust emission standards.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ..., hydrocarbon, and particulate matter exhaust emission standards. 89.112 Section 89.112 Protection of....112 Oxides of nitrogen, carbon monoxide, hydrocarbon, and particulate matter exhaust emission... emissions of oxides of nitrogen, carbon monoxide, hydrocarbon, and nonmethane hydrocarbon are measured using...

  8. Selected constituents in the smokes of U. S. commercial cigaretts: tar, nicotine, carbon monoxide and carbon dioxide

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jenkins, R.A.; Quincy, R.B.; Guerin, M.R.

    One hundred twenty-one brands of United States commercial cigarettes were analyzed for their deliveries of tar, nicotine, carbon monoxide, and carbon dioxide under standard analytical smoking conditions. The sample included both filter and nonfilter cigarettes. Comparisons of carbon monoxide deliveries over the range of observed tar deliveries indicated a very high correlation between CO and tar for filter cigarettes, but nonfilter cigarettes tended to produce much less CO than would have been predicted from their tar deliveries. Comparison of ORNL nicotine values for specific brands with those determined by the Federal Trade Commission yield no statistically significant differences between laboratories.more » 4 figures, 6 tables.« less

  9. Risk and Protective Factors for Fires, Burns, and Carbon Monoxide Poisoning in U.S. Households

    PubMed Central

    Runyan, Carol W.; Johnson, Renee M.; Yang, Jingzhen; Waller, Anna E.; Perkis, David; Marshall, Stephen W.; Coyne-Beasley, Tamera; McGee, Kara S.

    2011-01-01

    Background More needs to be known about the prevalence of risk and protective factors for fires, burns, and carbon monoxide poisoning in U.S. households. Methods A random-digit-dial survey was conducted about home safety with 1003 respondents representing households in the continental United States. Descriptive statistics assess the prevalence of risk and protective factors for fires, burns, and carbon monoxide overall, and by demographic characteristics, household structure, region, and residential tenure. The data were weighted to adjust for nonresponse and to reflect the U.S. population. Results Although most respondents reported having a smoke alarm (97%), and 80% reported having one on each level of their home, <20% reported checking the alarm at least every 3 months. Seventy-one percent reported having a fire extinguisher, 29% had a carbon monoxide detector, and 51% of those living with at least one other person had a fire escape plan. Few could report the temperature of their hot water at the tap (9%), or the setting on the hot water heater (25%). Only 6% had an antiscald device. Conclusions Results suggest that there is much room for improvement regarding adoption of measures to prevent fires, burns, and carbon monoxide poisoning. Further investigations of the efficacy of carbon monoxide detectors, fire extinguishers, and escape plans, as well as effectiveness studies of fire and burn-prevention efforts are needed. PMID:15626564

  10. Risk and protective factors for fires, burns, and carbon monoxide poisoning in U.S. households.

    PubMed

    Runyan, Carol W; Johnson, Renee M; Yang, Jingzhen; Waller, Anna E; Perkis, David; Marshall, Stephen W; Coyne-Beasley, Tamera; McGee, Kara S

    2005-01-01

    More needs to be known about the prevalence of risk and protective factors for fires, burns, and carbon monoxide poisoning in U.S. households. A random-digit-dial survey was conducted about home safety with 1003 respondents representing households in the continental United States. Descriptive statistics assess the prevalence of risk and protective factors for fires, burns, and carbon monoxide overall, and by demographic characteristics, household structure, region, and residential tenure. The data were weighted to adjust for nonresponse and to reflect the U.S. population. Although most respondents reported having a smoke alarm (97%), and 80% reported having one on each level of their home, <20% reported checking the alarm at least every 3 months. Seventy-one percent reported having a fire extinguisher, 29% had a carbon monoxide detector, and 51% of those living with at least one other person had a fire escape plan. Few could report the temperature of their hot water at the tap (9%), or the setting on the hot water heater (25%). Only 6% had an antiscald device. Results suggest that there is much room for improvement regarding adoption of measures to prevent fires, burns, and carbon monoxide poisoning. Further investigations of the efficacy of carbon monoxide detectors, fire extinguishers, and escape plans, as well as effectiveness studies of fire and burn-prevention efforts are needed.

  11. [Carbon monoxide poisoning by a heating system].

    PubMed

    Dietz, Eric; Gehl, Axel; Friedrich, Peter; Kappus, Stefan; Petter, Franz; Maurer, Klaus; Püschel, Klaus

    2016-01-01

    A case of accidental carbon monoxide poisoning in several occupants of two neighboring residential buildings in Hamburg-Harburg (Germany) caused by a defective gas central heating system is described. Because of leaks in one of the residential buildings and the directly adjacent wall of the neighboring house, the gas could spread and accumulated in both residential buildings, which resulted in a highly dangerous situation. Exposure to the toxic gas caused mild to severe intoxication in 15 persons. Three victims died still at the site of the accident. Measures to protect the occupants were taken only with a great delay. As symptoms were unspecific, it was not realized that the various alarms given by persons involved in the accident were related to the same cause. In order to take appropriate measures in time it is indispensible to recognize, assess and check potential risks, which can be done by using carbon monoxide warning devices and performing immediate COHb measurements with special pulse oximeters on site. Moreover, the COHb content in the blood should be routinely determined in all patients admitted to an emergency department with unspecific symptoms.

  12. 40 CFR 52.1682 - Control strategy: Carbon monoxide.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS (CONTINUED) New York § 52.1682 Control strategy... plan for the New York portion of the New York—Northern New Jersey—Long Island Carbon Monoxide... plan. The November 23, 1999, request to redesignate the New York portion of the New York—Northern New...

  13. 40 CFR 60.263 - Standard for carbon monoxide.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 7 2012-07-01 2012-07-01 false Standard for carbon monoxide. 60.263 Section 60.263 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Ferroalloy Production Facilities § 60.263 Standard for carbo...

  14. 40 CFR 86.1522 - Carbon monoxide analyzer calibration.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 20 2013-07-01 2013-07-01 false Carbon monoxide analyzer calibration. 86.1522 Section 86.1522 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) CONTROL OF EMISSIONS FROM NEW AND IN-USE HIGHWAY VEHICLES AND ENGINES (CONTINUED) Emission Regulations for Otto-Cycle Heavy-Duty...

  15. 40 CFR 60.263 - Standard for carbon monoxide.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 7 2014-07-01 2014-07-01 false Standard for carbon monoxide. 60.263 Section 60.263 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Ferroalloy Production Facilities § 60.263 Standard for carbo...

  16. 40 CFR 86.1522 - Carbon monoxide analyzer calibration.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 19 2011-07-01 2011-07-01 false Carbon monoxide analyzer calibration. 86.1522 Section 86.1522 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) CONTROL OF EMISSIONS FROM NEW AND IN-USE HIGHWAY VEHICLES AND ENGINES (CONTINUED) Emission Regulations for Otto-Cycle Heavy-Duty...

  17. 40 CFR 60.263 - Standard for carbon monoxide.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 7 2013-07-01 2013-07-01 false Standard for carbon monoxide. 60.263 Section 60.263 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Ferroalloy Production Facilities § 60.263 Standard for carbo...

  18. Nano-crystalline porous tin oxide film for carbon monoxide sensing

    NASA Technical Reports Server (NTRS)

    Liu, Chung-Chiun (Inventor); Savinell, Robert F. (Inventor); Jin, Zhihong (Inventor)

    2000-01-01

    A tin oxide sol is deposited on platinum electrodes (12) of a sensor (10). The sol is calcined at a temperature of 500 to 800.degree. C. to produce a thin film of tin oxide with a thickness of about 150 nm to 2 .mu. and having a nano-crystalline structure with good stability. The sensor rapidly detects reducing gases, such as carbon monoxide, or hydrocarbons and organic vapors. Sensors using films calcined at around 700.degree. C. have high carbon monoxide selectivity with a response time of around 4 minutes and a recovery time of 1 minute, and therefore provide good detection systems for detection of trace amounts of pollutants such as toxic and flammable gases in homes, industrial settings, and hospitals.

  19. Characteristics of Children with Acute Carbon Monoxide Poisoning in Ankara: A Single Centre Experience.

    PubMed

    Unsal Sac, Rukiye; Taşar, Medine Ayşin; Bostancı, İlknur; Şimşek, Yurda; Bilge Dallar, Yıldız

    2015-12-01

    The purpose of the study was to define characteristics of children with acute carbon monoxide poisoning. Eighty children hospitalized with acute carbon monoxide poisoning were recruited prospectively over a period of 12 months. Sociodemographic features, complaints and laboratory data were recorded. When the patient was discharged, necessary preventive measures to be taken were explained to parents. One month later, the parents were questioned during a control examination regarding the precautions that they took. The ages of the cases were between one month and 16 yr. Education levels were low in 86.2% of mothers and 52.6% of fathers. All families had low income and 48.8% did not have formal housing. The source of the acute carbon monoxide poisoning was stoves in 71.2% of cases and hot-water heaters in 28.8% of cases. Three or more people were poisoned at home in 85.1% of the cases. The most frequent symptoms of poisoning were headache and vertigo (58.8%). Median carboxyhemoglobin levels at admission to the hospital and discharge were measured as 19.5% and 1.1% (P < 0.001). When families were called for re-evaluation, it was determined that most of them had taken the necessary precautions after the poisoning incident (86.3%). This study determined that children with acute childhood carbon monoxide poisoning are usually from families with low socioeconomic and education levels. Education about prevention should be provided to all people who are at risk of carbon monoxide poisoning before a poisoning incident occurs.

  20. Characteristics of Children with Acute Carbon Monoxide Poisoning in Ankara: A Single Centre Experience

    PubMed Central

    Unsal Sac, Rukiye; Bostancı, İlknur; Şimşek, Yurda; Bilge Dallar, Yıldız

    2015-01-01

    The purpose of the study was to define characteristics of children with acute carbon monoxide poisoning. Eighty children hospitalized with acute carbon monoxide poisoning were recruited prospectively over a period of 12 months. Sociodemographic features, complaints and laboratory data were recorded. When the patient was discharged, necessary preventive measures to be taken were explained to parents. One month later, the parents were questioned during a control examination regarding the precautions that they took. The ages of the cases were between one month and 16 yr. Education levels were low in 86.2% of mothers and 52.6% of fathers. All families had low income and 48.8% did not have formal housing. The source of the acute carbon monoxide poisoning was stoves in 71.2% of cases and hot-water heaters in 28.8% of cases. Three or more people were poisoned at home in 85.1% of the cases. The most frequent symptoms of poisoning were headache and vertigo (58.8%). Median carboxyhemoglobin levels at admission to the hospital and discharge were measured as 19.5% and 1.1% (P < 0.001). When families were called for re-evaluation, it was determined that most of them had taken the necessary precautions after the poisoning incident (86.3%). This study determined that children with acute childhood carbon monoxide poisoning are usually from families with low socioeconomic and education levels. Education about prevention should be provided to all people who are at risk of carbon monoxide poisoning before a poisoning incident occurs. PMID:26713060

  1. 40 CFR 86.522-78 - Carbon monoxide analyzer calibration.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... thereafter the NDIR carbon monoxide analyzer shall be checked for response to water vapor and CO2: (1) Follow... zero grade nitrogen. (3) Bubble a mixture of 3 percent CO2 in N2 through water at room temperature and...

  2. 40 CFR 86.522-78 - Carbon monoxide analyzer calibration.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... thereafter the NDIR carbon monoxide analyzer shall be checked for response to water vapor and CO2: (1) Follow... zero grade nitrogen. (3) Bubble a mixture of 3 percent CO2 in N2 through water at room temperature and...

  3. 40 CFR 86.522-78 - Carbon monoxide analyzer calibration.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... thereafter the NDIR carbon monoxide analyzer shall be checked for response to water vapor and CO2: (1) Follow... zero grade nitrogen. (3) Bubble a mixture of 3 percent CO2 in N2 through water at room temperature and...

  4. 40 CFR 86.522-78 - Carbon monoxide analyzer calibration.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... thereafter the NDIR carbon monoxide analyzer shall be checked for response to water vapor and CO2: (1) Follow... zero grade nitrogen. (3) Bubble a mixture of 3 percent CO2 in N2 through water at room temperature and...

  5. 40 CFR 52.1627 - Control strategy and regulations: Carbon monoxide.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... § 52.1627 Control strategy and regulations: Carbon monoxide. (a) Part D Approval. The Albuquerque... Section 172 of the Clean Air Act, and is therefore approved. (b) Approval—The Albuquerque/Bernalillo...

  6. 40 CFR 52.1627 - Control strategy and regulations: Carbon monoxide.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... § 52.1627 Control strategy and regulations: Carbon monoxide. (a) Part D Approval. The Albuquerque... Section 172 of the Clean Air Act, and is therefore approved. (b) Approval—The Albuquerque/Bernalillo...

  7. Anaesthetic properties of carbon monoxide and other gases in relation to plants, insects, and centipedes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zimmerman, P.W.

    The anaesthetic effect of carbon monoxide, carbon dioxide, propylene, butylene, ethylene, and acetylene, when mixed with oxygen, was tested on ten different species of insects and centipedes. The lowest concentrations found to cause anaesthesia are given in per cent by volume as follows: propylene, for centipede, 30; katydid, 75; rose chafer, 60. Carbon monoxide, for centipede, 81.5; katydid, 89, rose chafer, 85. Butylene, for centipede, 5; katydid, 10; rose chafer, 40. Ethylene or acetylene, for centipede, katydid, and rose chafer, 100. Carbon dioxide, for rose chafer, 30. Ethylene was the most effective plant anaesthetic, 0.0005 per cent stopping growth movementsmore » of tomato and sunflower plants as shown by motion pictures; 0.001 per cent stopped elongation of sweet pea seedlings, while 0.00001 per cent retarded elongation nearly 50 per cent. The degree of retardation in growth from ethylene gas varied with the concentration and the plant species. Acetylene and propylene were about equally effective as plant anaesthetics. Both were approximately 10 times as effective as carbon monoxide. Mimosa pudica lost its capacity to respond to external stimuli while being exposed to 0.25 per cent of carbon monoxide, but became normal again upon being removed from the gas. 3 references, 4 tables.« less

  8. 40 CFR 90.317 - Carbon monoxide analyzer calibration.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... its initial use and annually thereafter, check the NDIR carbon monoxide analyzer for response to water vapor and CO2. (1) Follow good engineering practices for instrument start-up and operation. Adjust the... CO2 in N2 through water at room temperature and record analyzer response. (4) An analyzer response of...

  9. 40 CFR 90.317 - Carbon monoxide analyzer calibration.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... its initial use and annually thereafter, check the NDIR carbon monoxide analyzer for response to water vapor and CO2. (1) Follow good engineering practices for instrument start-up and operation. Adjust the... CO2 in N2 through water at room temperature and record analyzer response. (4) An analyzer response of...

  10. 40 CFR 90.317 - Carbon monoxide analyzer calibration.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... its initial use and annually thereafter, check the NDIR carbon monoxide analyzer for response to water vapor and CO2. (1) Follow good engineering practices for instrument start-up and operation. Adjust the... CO2 in N2 through water at room temperature and record analyzer response. (4) An analyzer response of...

  11. 40 CFR 90.317 - Carbon monoxide analyzer calibration.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... its initial use and annually thereafter, check the NDIR carbon monoxide analyzer for response to water vapor and CO2. (1) Follow good engineering practices for instrument start-up and operation. Adjust the... CO2 in N2 through water at room temperature and record analyzer response. (4) An analyzer response of...

  12. Absorption of nicotine and carbon monoxide from passive smoking under natural conditions of exposure.

    PubMed Central

    Jarvis, M J; Russell, M A; Feyerabend, C

    1983-01-01

    Seven non-smokers were exposed to tobacco smoke under natural conditions for two hours in a public house. Measures of nicotine and cotinine in plasma, saliva, and urine and expired air carbon monoxide all showed reliable increases. The concentrations of carbon monoxide and nicotine after exposure averaged 15.7% and 7.5% respectively of the values found in heavy smokers. Although the increase in expired air carbon monoxide of 5.9 ppm was similar to increases in smokers after a single cigarette, the amount of nicotine absorbed was between a tenth and a third of the amount taken in from one cigarette. Since this represented a relatively extreme acute natural exposure, any health risks of passive smoking probably depend less on quantitative factors than on qualitative differences between sidestream and mainstream smoke. PMID:6648864

  13. Shock tube measurements of growth constants in the branched chain formaldehyde-carbon monoxide-oxygen system

    NASA Technical Reports Server (NTRS)

    Brabbs, T. A.; Brokaw, R. S.

    1982-01-01

    Exponential free radical growth constants were measured for formaldehyde carbon monoxide-oxygen systems by monitoring the growth of oxygen atom concentration as manifested by CO flame band emission. Data were obtained over the temperature range of 1200 to 2000 K. The data were analyzed using a formaldehyde oxidation mechanism involving 12 elementary reaction steps. The computed growth constants are roughly in accord with experimental values, but are much more temperature dependent. The data was also analyzed assuming formaldehyde is rapidly decomposed to carbon monoxide and hydrogen. Growth constants computed for the resulting carbon monoxide hydrogen oxygen mixtures have a temperature dependence similar to experiments; however, for most mixtures, the computed growth constants were larger than experimental values.

  14. An operando FTIR spectroscopic and kinetic study of carbon monoxide pressure influence on rhodium-catalyzed olefin hydroformylation.

    PubMed

    Kubis, Christoph; Sawall, Mathias; Block, Axel; Neymeyr, Klaus; Ludwig, Ralf; Börner, Armin; Selent, Detlef

    2014-09-08

    The influence of carbon monoxide concentration on the kinetics of the hydroformylation of 3,3-dimethyl-1-butene with a phosphite-modified rhodium catalyst has been studied for the pressure range p(CO)=0.20-3.83 MPa. Highly resolved time-dependent concentration profiles of the organometallic intermediates were derived from IR spectroscopic data collected in situ for the entire olefin-conversion range. The dynamics of the catalyst and organic components are described by enzyme-type kinetics with competitive and uncompetitive inhibition reactions involving carbon monoxide taken into account. Saturation of the alkyl-rhodium intermediates with carbon monoxide as a cosubstrate occurs between 1.5 and 2 MPa of carbon monoxide pressure, which brings about a convergence of aldehyde regioselectivity. Hydrogenolysis of the acyl intermediate is fast at 30 °C and low pressure of p(CO)=0.2 MPa, but is of minus first order with respect to the solution concentration of carbon monoxide. Resting 18-electron hydrido and acyl complexes that correspond to early and late rate-determining states, respectively, coexist as long as the conversion of the substrate is not complete. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  15. [Risk of chronic carbon monoxide poisoning in automobile garages. Results of a study in the Lausanne region].

    PubMed

    Köhl, U; Lob, M

    1975-01-11

    Clinical and physiologic data on chronic carbon monoxide poisoning are reviewed and the results of an investigation involving 7 garages in the Lausanne (Switzerland) area are reported. The aim was a practical approach to the relationships between carbon monoxide level in the air, COHb and clinical picture. The study covered working conditions (especially ventilation) but did not take into account of other factors (stresses) which may effect the parameters investigated. CO was measured by continuous recording with an MSA Carbon Monoxide Alarm and the hourly and daily averages were determined. The garage personnel replied to a questionnaire and underwent a brief clinical examination including taking of digital blood samples for measurement of hematocrit and carboxyhemoglobin level by the method of COMMINS and LAWTHER as modified by BUCHWALD. One of the garages did not meet present health requirements. Statistical analysis revealed a significant correlation between carbon monoxide and carboxyhemoglobin. The incidence of complaints was highest in poorly ventilated garages. On the basis of COHb level in the total group of employees, together with data from individual histories, it is possible to evaluate the risk of carbon monoxide poisoning in a given garage.

  16. 40 CFR 90.317 - Carbon monoxide analyzer calibration.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... analyzer to optimize performance on the most sensitive range to be used. (2) Zero the carbon monoxide analyzer with either purified synthetic air or zero-grade nitrogen. (3) Bubble a mixture of three percent... more than one percent of full scale for ranges above 300 ppm full scale or more than three ppm on...

  17. Concentration and Transport of Carbon Monoxide from the California Wildfires

    NASA Image and Video Library

    2009-09-04

    Carbon monoxide in the smoke from the Station fire was lofted high into the atmosphere, where it was observed by JPL Atmospheric Infrared Sounder instrument onboard NASA Aqua satellite. Animation available at the Photojournal.

  18. MRI and clinical manifestations of delayed encephalopathy after carbon monoxide poisoning.

    PubMed

    Wang, Xiahong; Li, Zhenyu; Berglass, Jacqueline; He, Wenlong; Zhao, Jianmin; Zhang, Min; Gao, Chongyang; Zhang, Caixia; Zhang, Huimin; Yi, Xuewei

    2016-11-01

    To explore the relationship between the clinical manifestations and functional magnetic resonance images of delayed encephalopathy after carbon monoxide intoxication. Six patients received the MRI were diagnosed with delayed encephalopathy after carbon monoxide (CO) poisoning. Clinical manifestations were observed in each patient. MRI revealed multiple lesions. The majority of the lesions were located in the globus pallidus, sub cortical white matter, and basal ganglia. The cognitive injury, akinetic mutism, fecal and uroclepsia, forced crying, forced laughing and extra pyramidal syndromes such as chorea and parkinsonism were manifested in clinic. Cognitive impairment improved greatly while involuntary movements only improved slightly after several months. Meanwhile brain MRI suggested remarkable improvement. Neuroimaging directly correlated with the clinical manifestations.

  19. 40 CFR 91.317 - Carbon monoxide analyzer calibration.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... to optimize performance on the most sensitive range to be used. (2) Zero the carbon monoxide analyzer with either purified synthetic air or zero-grade nitrogen. (3) Bubble a mixture of three percent CO2 in... than one percent of full scale for ranges above 300 ppm full scale or more than three ppm on ranges...

  20. Carbon Monoxide as an Electron Donor for the Biological Reduction of Sulphate

    PubMed Central

    Parshina, Sofiya N.; Sipma, Jan; Henstra, Anne Meint; Stams, Alfons J. M.

    2010-01-01

    Several strains of Gram-negative and Gram-positive sulphate-reducing bacteria (SRB) are able to use carbon monoxide (CO) as a carbon source and electron donor for biological sulphate reduction. These strains exhibit variable resistance to CO toxicity. The most resistant SRB can grow and use CO as an electron donor at concentrations up to 100%, whereas others are already severely inhibited at CO concentrations as low as 1-2%. Here, the utilization, inhibition characteristics, and enzymology of CO metabolism as well as the current state of genomics of CO-oxidizing SRB are reviewed. Carboxydotrophic sulphate-reducing bacteria can be applied for biological sulphate reduction with synthesis gas (a mixture of hydrogen and carbon monoxide) as an electron donor. PMID:20628586

  1. Integrated Science Assessment (ISA) for Carbon Monoxide ...

    EPA Pesticide Factsheets

    EPA announced the availability of the final report, Integrated Science Assessment (ISA) for Carbon Monoxide (CO). This report is EPA’s latest evaluation of the scientific literature on the potential human health and welfare effects associated with ambient exposures to CO. The development of this document is part of the Agency's periodic review of the national ambient air quality standards (NAAQS) for CO. The recently completed CO ISA and supplementary annexes, in conjunction with additional technical and policy assessments developed by EPA’s Office of Air and Radiation, will provide the scientific basis to inform EPA decisions related to the review of the current CO NAAQS. The integrated Plan for Review of the National Ambient Air Quality Standards for Carbon Monoxide (U.S. EPA, 2008, 193995) identifies key policy-relevant questions that provide a framework for this assessment of the scientific evidence. These questions frame the entire review of the NAAQS for CO and thus are informed by both science and policy considerations. The ISA organizes, presents, and integrates the scientific evidence which is considered along with findings from risk analyses and policy considerations to help the U.S. Environmental Protection Agency (EPA) address these questions during the NAAQS review.

  2. 40 CFR 52.1164 - Localized high concentrations-carbon monoxide.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... meteorological modeling, traffic flow monitoring, air quality monitoring and other measures necessary to... reviewing all available traffic data, physical site data and air quality and meteorological data for all... containing measures to regulate traffic and parking so as to reduce carbon monoxide emissions to achieve air...

  3. 40 CFR 52.1164 - Localized high concentrations-carbon monoxide.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... meteorological modeling, traffic flow monitoring, air quality monitoring and other measures necessary to... reviewing all available traffic data, physical site data and air quality and meteorological data for all... containing measures to regulate traffic and parking so as to reduce carbon monoxide emissions to achieve air...

  4. 40 CFR 52.1164 - Localized high concentrations-carbon monoxide.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... meteorological modeling, traffic flow monitoring, air quality monitoring and other measures necessary to... reviewing all available traffic data, physical site data and air quality and meteorological data for all... containing measures to regulate traffic and parking so as to reduce carbon monoxide emissions to achieve air...

  5. 40 CFR 52.1164 - Localized high concentrations-carbon monoxide.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... meteorological modeling, traffic flow monitoring, air quality monitoring and other measures necessary to... reviewing all available traffic data, physical site data and air quality and meteorological data for all... containing measures to regulate traffic and parking so as to reduce carbon monoxide emissions to achieve air...

  6. 40 CFR 52.1164 - Localized high concentrations-carbon monoxide.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... meteorological modeling, traffic flow monitoring, air quality monitoring and other measures necessary to... reviewing all available traffic data, physical site data and air quality and meteorological data for all... containing measures to regulate traffic and parking so as to reduce carbon monoxide emissions to achieve air...

  7. Material processing with hydrogen and carbon monoxide on Mars

    NASA Astrophysics Data System (ADS)

    Hepp, Aloysius F.; Landis, Geoffrey A.; Linne, Diane L.

    Several novel proposals are examined for propellant production from carbon dioxide and monoxide and hydrogen. Potential uses were also examined of CO as a fuel or as a reducing agent in metal oxide processing as obtained or further reduced to carbon. Hydrogen can be reacted with CO to produce a wide variety of hydrocarbons, alcohols, and other organic compounds. Methanol, produced by Fischer-Tropsch chemistry may be useful as a fuel; it is easy to store and handle because it is a liquid at Mars temperatures. The reduction of CO2 to hydrocarbons such as methane or acetylene can be accomplished with hydrogen. Carbon monoxide and hydrogen require cryogenic temperatures for storage as liquids. Noncryogenic storage of hydrogen may be accomplished using hydrocarbons, inorganic hydrides, or metal hydrides. Noncryogenic storage of CO may be accomplished in the form of iron carbonyl (FE(CO)5) or other metal carbonyls. Low hydrogen content fuels such as acetylene (C2H2) may be effective propellants with low requirements for earth derived resources. The impact on manned Mars missions of alternative propellant production and utilization is discussed.

  8. Material processing with hydrogen and carbon monoxide on Mars

    NASA Astrophysics Data System (ADS)

    Hepp, Aloysius F.; Linne, Diane L.; Landis, Geoffrey A.

    Several novel proposals are examined for propellant production from carbon dioxide and monoxide and hydrogen. Potential uses were also examined of CO as a fuel or as a reducing agent in metal oxide processing as obtained or further reduced to carbon. Hydrogen can be reacted with CO to produce a wide variety of hydrocarbons, alcohols, and other organic compounds. Methanol, produced by Fischer-Tropsch chemistry may be useful as a fuel; it is easy to store and handle because it is a liquid at Mars temperatures. The reduction of CO2 to hydrocarbons such as methane or acetylene can be accomplished with hydrocarbons. Carbon monoxide and hydrogen require cryogenic temperatures for storage as liquid. Noncryogenic storage of hydrogen may be accomplished using hydrocarbons, inorganic hydrides, or metal hydrides. Noncryogenic storage of CO may be accomplished in the form of iron carbonyl (FE(CO)5) or other metal carbonyls. Low hydrogen content fuels such as acetylene (C2H2) may be effective propellants with low requirements for earth derived resources. The impact on manned Mars missions of alternative propellant production and utilization is discussed.

  9. Material processing with hydrogen and carbon monoxide on Mars

    NASA Technical Reports Server (NTRS)

    Hepp, Aloysius F.; Landis, Geoffrey A.; Linne, Diane L.

    1991-01-01

    Several novel proposals are examined for propellant production from carbon dioxide and monoxide and hydrogen. Potential uses were also examined of CO as a fuel or as a reducing agent in metal oxide processing as obtained or further reduced to carbon. Hydrogen can be reacted with CO to produce a wide variety of hydrocarbons, alcohols, and other organic compounds. Methanol, produced by Fischer-Tropsch chemistry may be useful as a fuel; it is easy to store and handle because it is a liquid at Mars temperatures. The reduction of CO2 to hydrocarbons such as methane or acetylene can be accomplished with hydrogen. Carbon monoxide and hydrogen require cryogenic temperatures for storage as liquids. Noncryogenic storage of hydrogen may be accomplished using hydrocarbons, inorganic hydrides, or metal hydrides. Noncryogenic storage of CO may be accomplished in the form of iron carbonyl (FE(CO)5) or other metal carbonyls. Low hydrogen content fuels such as acetylene (C2H2) may be effective propellants with low requirements for earth derived resources. The impact on manned Mars missions of alternative propellant production and utilization is discussed.

  10. 40 CFR 86.222-94 - Carbon monoxide analyzer calibration.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... PROGRAMS (CONTINUED) CONTROL OF EMISSIONS FROM NEW AND IN-USE HIGHWAY VEHICLES AND ENGINES Emission Regulations for 1994 and Later Model Year Gasoline-Fueled New Light-Duty Vehicles, New Light-Duty Trucks and New Medium-Duty Passenger Vehicles; Cold Temperature Test Procedures § 86.222-94 Carbon monoxide...

  11. Carbon monoxide poisoning in children riding in the back of pickup trucks.

    PubMed

    Hampson, N B; Norkool, D M

    OBJECTIVE - To describe the case characteristics of a series of children poisoned with carbon monoxide while traveling in the back of pickup trucks. DESIGN - Pediatric cases referred for treatment of carbon monoxide poisoning with hyperbaric oxygen between 1986 and 1991 were reviewed. Those cases that occurred during travel in the back of pickup trucks were selected. Clinical follow-up by telephone interview ranged from 2 to 55 months. SETTING - A private, urban, tertiary care center in Seattle, Wash. PATIENTS - Twenty children ranging from 4 to 16 years of age. INTERVENTION - All patients were treated with hyperbaric oxygen. MAIN OUTCOME MEASURES - Characteristics of the poisoning incident and clinical patient outcome. RESULTS - Of 68 pediatric patients treated for accidental carbon monoxide poisoning, 20 cases occurred as children rode in the back of pickup trucks. In 17 of these, the children were riding under a rigid closed canopy on the rear of the truck, while three episodes occurred as children rode beneath a tarpaulin. Average carboxyhemoglobin level on emergency department presentation was 18.2% +/- 2.4% (mean +/- SEM; range, 1.6% to 37.0%). Loss of consciousness occurred in 15 of the 20 children. One child died of cerebral edema, one had permanent neurologic deficits, and 18 had no recognizable sequelae related to the episode. In all cases, the truck exhaust system had a previously known leak or a tail pipe that exited at the rear rather than at the side of the pickup truck. CONCLUSIONS - Carbon monoxide poisoning is a significant hazard for children who ride in the back of pickup trucks. If possible, this practice should be avoided.

  12. Exergy parametric study of carbon monoxide oxidation in moist air

    NASA Astrophysics Data System (ADS)

    Souidi, Ferhat; Benmalek, Toufik; Yesaad, Billel; Baik, Mouloud

    2015-12-01

    This study aims to analyze the oxidation of carbon monoxide in moist air from the second thermodynamic law aspect. A mathematical model of laminar premixed flame in a stagnation point flow has been achieved by numerical solution of the boundary layer equation using a self-made code. The chemical kinetic mechanism for flameless combustion of fuel, which is a mixture of carbon monoxide, oxygen, and water vapor, is modeled by 34 elementary reactions that incorporate (09) nine chemical species: CO, O, CO2, O2, H2O, H, H2, HO2, and OH. The salient point is that for all the parameters we considered, the exergy of the process is completely destroyed by irreversibilities. From the chemical viewpoint, the OH radical plays an essential role in CO oxidation. This latter point has already been mentioned by previous investigators.

  13. Catalysis of carbon monoxide methanation by deep sea manganate minerals

    NASA Technical Reports Server (NTRS)

    Cabrera, A. L.; Maple, M. B.; Arrhenius, G.

    1990-01-01

    The catalytic activity of deep sea manganese nodule minerals for the methanation of carbon monoxide was measured with a microcatalytic technique between 200 and 460 degrees C. The manganate minerals were activated at 248 degrees C by immersion into a stream of hydrogen in which pulses of carbon monoxide were injected. Activation energies for the methanation reaction and hydrogen desorption from the manganate minerals were obtained and compared with those of pure nickel. Similar energy values indicate that the activity of the nodule materials for the reaction appears to be related to the amount of reducible transition metals present in the samples (ca. 11 wt.-%). Since the activity of the nodule minerals per gram is comparable to that of pure nickel, most of the transition metal ions located between manganese oxide layers appear to be exposed and available to catalyze the reaction.

  14. Complexes of horseradish peroxidase with formate, acetate, and carbon monoxide.

    PubMed

    Carlsson, Gunilla H; Nicholls, Peter; Svistunenko, Dimitri; Berglund, Gunnar I; Hajdu, Janos

    2005-01-18

    Carbon monoxide, formate, and acetate interact with horseradish peroxidase (HRP) by binding to subsites within the active site. These ligands also bind to catalases, but their interactions are different in the two types of enzymes. Formate (notionally the "hydrated" form of carbon monoxide) is oxidized to carbon dioxide by compound I in catalase, while no such reaction is reported to occur in HRP, and the CO complex of ferrocatalase can only be obtained indirectly. Here we describe high-resolution crystal structures for HRP in its complexes with carbon monoxide and with formate, and compare these with the previously determined HRP-acetate structure [Berglund, G. I., et al. (2002) Nature 417, 463-468]. A multicrystal X-ray data collection strategy preserved the correct oxidation state of the iron during the experiments. Absorption spectra of the crystals and electron paramagnetic resonance data for the acetate and formate complexes in solution correlate electronic states with the structural results. Formate in ferric HRP and CO in ferrous HRP bind directly to the heme iron with iron-ligand distances of 2.3 and 1.8 A, respectively. CO does not bind to the ferric iron in the crystal. Acetate bound to ferric HRP stacks parallel with the heme plane with its carboxylate group 3.6 A from the heme iron, and without an intervening solvent molecule between the iron and acetate. The positions of the oxygen atoms in the bound ligands outline a potential access route for hydrogen peroxide to the iron. We propose that interactions in this channel ensure deprotonation of the proximal oxygen before binding to the heme iron.

  15. The distribution of middle tropospheric carbon monoxide during early October 1984

    NASA Technical Reports Server (NTRS)

    Reichle, Henry G., Jr.; Connors, Vickie S.; Wallio, H. Andrew; Holland, J. Alvin; Sherrill, Robert T.; Casas, Joseph C.; Gormsen, Barbara B.

    1989-01-01

    The distribution of middle tropospheric carbon monoxide measure by the Measurement of Air Pollution from Satellites (MAPS) instrument carried aboard the space shuttle is reported. The data represent average mixing ratios in the middle troposphere and are presented in the form of maps that show the carbon monoxide mixing ratios averaged for 6 days of the mission. Comparisons with concurrent, direct measurements taken aboard aircraft show that the inferred concentrations are systematically low by from 20 to 40 percent depending upon which direct measurement calibration standard is used. The data show that there are very large CO sources resulting from biomass burning over South America and southern Africa. Measured mixing ratios were high over northeast Asia and were highly variable over Europe.

  16. EDUCATION LEVEL IS GREATEST RISK-FACTOR IN CARBON MONOXIDE POISONING

    EPA Science Inventory

    Carbon monoxide (CO) is a toxic by-product of the combustion of fossil fuels. In confined spaces, inefficient combustion sources, such as furnaces, stoves, kerosene heaters and automobiles can generate levels of CO that interrupt oxygen transport throughout the body, potentially ...

  17. Neuroprotective, neurotherapeutic, and neurometabolic effects of carbon monoxide.

    PubMed

    Mahan, Vicki L

    2012-12-27

    Studies in animal models show that the primary mechanism by which heme-oxygenases impart beneficial effects is due to the gaseous molecule carbon monoxide (CO). Produced in humans mainly by the catabolism of heme by heme-oxygenase, CO is a neurotransmitter important for multiple neurologic functions and affects several intracellular pathways as a regulatory molecule. Exogenous administration of inhaled CO or carbon monoxide releasing molecules (CORM's) impart similar neurophysiological responses as the endogenous gas. Its' involvement in important neuronal functions suggests that regulation of CO synthesis and biochemical properties may be clinically relevant to neuroprotection and the key may be a change in metabolic substrate from glucose to lactate. Currently, the drug is under development as a therapeutic agent and safety studies in humans evaluating the safety and tolerability of inhaled doses of CO show no clinically important abnormalities, effects, or changes over time in laboratory safety variables. As an important therapeutic option, inhaled CO has entered clinical trials and its clinical role as a neuroprotective and neurotherapeutic agent has been suggested. In this article, we review the neuroprotective effects of endogenous CO and discuss exogenous CO as a neuroprotective and neurotherapeutic agent.

  18. Carbon monoxide poisoning--Weld County, Colorado, 1993.

    PubMed

    1994-10-28

    In March 1993, the Colorado Department of Public Health and Environment (CDPHE) was notified that six family members residing in a home in Weld County had suffered carbon monoxide (CO) poisoning; five of the persons died. An investigation indicated that the source of CO had been a van parked in the garage of the home; the van had been left running, and the exhaust fumes leaked into the home. This report summarizes the investigation of this incident.

  19. 40 CFR 86.222-94 - Carbon monoxide analyzer calibration.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 19 2013-07-01 2013-07-01 false Carbon monoxide analyzer calibration. 86.222-94 Section 86.222-94 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) CONTROL OF EMISSIONS FROM NEW AND IN-USE HIGHWAY VEHICLES AND ENGINES Emission Regulations for 1994 and Later Model Year...

  20. Levels of maximum end-expiratory carbon monoxide and certain cardiovascular parameters following hubble-bubble smoking.

    PubMed

    Shafagoj, Yanal A; Mohammed, Faisal I

    2002-08-01

    The physiological effects of cigarette smoking have been widely studied, however, little is known regarding the effects of smoking hubble-bubble. We examined the acute effects of hubble-bubble smoking on heart rate, systolic, diastolic, and mean arterial blood pressure and maximum end-expiratory carbon monoxide. This study was carried out in the student laboratory, School of Medicine, Department of Physiology, University of Jordan, Amman, Jordan, during the summer of 1999. In 18 healthy habitual hubble-bubble smokers, heart rate, blood pressure, and maximum end-expiratory carbon monoxide was measured before, during and post smoking of one hubble-bubble run (45 minutes). Compared to base line (time zero), at the end of smoking heart rate, systolic blood pressure, diastolic blood pressure, mean arterial blood pressure, and maximum end-expiratory carbon monoxide were increased 16 2.4 beats per minute, 6.7 2.5 mm Hg, 4.4 1.6 mm Hg, 5.2 1.7 mm Hg, and 14.2 1.8 ppm, (mean standard error of mean, P<.05). Acute short-term active hubble-bubble smoking elicits a modest increase in heart rate, systolic blood pressure, diastolic blood pressure, mean arterial blood pressure and maximum end-expiratory carbon monoxide in healthy hubble-bubble smokers.

  1. Pathology of carbon monoxide poisoning in two cats.

    PubMed

    Sobhakumari, Arya; Poppenga, Robert H; Pesavento, J Brad; Uzal, Francisco A

    2018-03-05

    Carbon monoxide (CO), a common cause of poisoning in human beings has also been implicated in the death of animals. Though there are multiple studies on CO poisoning and relevant lethal blood COHb concentrations in humans, there are no reliable reports of diagnostic lethal carboxyhemoglobin percentage of saturation (COHb%) in cats. Additionally, due to shared housing environments, exposures to companion animals can be a surrogate for lethal exposures in human beings and provide valuable information in concurrent forensic investigations. Two adult Singapura brown ticked cats were submitted to the California Animal Health and Food Safety Laboratory (CAHFS) for necropsy and diagnostic work-up. These animals were found dead along with their two deceased owners. Similar lesions were observed in both cats. At necropsy, gross lesions consisted of multifocal, large, irregular, bright red spots on the skin of the abdomen and the inner surface of ear pinnae, bright red muscles and blood. The carcasses, and tissues fixed in formalin retained the bright red discoloration for up to two weeks. Microscopic lesions included diffuse pulmonary congestion and edema, and multifocal intense basophilia of cardiomyocytes mostly affecting whole fibers or occasionally a portion of the fiber. Based on the clinical history,gross and microscopic changes, cyanide or carbon monoxide poisoning was suspected. Blood samples analyzed for carbon monoxide showed 57 and 41% carboxyhemoglobin COHb%. Muscle samples were negative for cyanide. There are no established reference values for lethal COHb concentration in cats. The COHb % values detected in this case which fell within the lethal range reported for other species, along with the gross lesions and unique histological findings in the heart suggest a helpful criteria for diagnosis of CO intoxication associated death in cats. This case demonstrates that since pets share the same environment as human beings and often are a part of their activities

  2. Hyperbaric oxygen therapy for carbon monoxide poisoning.

    PubMed

    Weaver, Lindell K

    2014-01-01

    Despite established exposure limits and safety standards, and the availability of carbon monoxide (CO) alarms, each year 50,000 people in the United States visit emergency departments for CO poisoning. Carbon monoxide poisoning can occur from brief exposures to high levels of CO, or from longer exposures to lower levels. Common symptoms include headaches, nausea and vomiting, dizziness, general malaise, and altered mental status. Some patients may have chest pain, shortness of breath and myocardial ischemia, and may require mechanical ventilation and treatment of shock. Individuals poisoned by CO often go on to develop neurological problems, including cognitive sequelae, anxiety and depression, persistent headaches, dizziness, sleep problems, motor weakness, vestibular and balance problems, gaze abnormalities, peripheral neuropathies, hearing loss, tinnitus and Parkinsonian-like syndrome. While breathing oxygen hastens the removal of carboxyhemoglobin (COHb), hyperbaric oxygen (HBO2) hastens COHb elimination and favorably modulates inflammatory processes instigated by CO poisoning, an effect not observed with breathing normobaric oxygen. Hyperbaric oxygen improves mitochondrial function, inhibits lipid peroxidation transiently, impairs leukocyte adhesion to injured microvasculature, and reduces brain inflammation caused by the CO-induced adduct formation of myelin basic protein. Based upon three supportive randomized clinical trials in humans and considerable evidence from animal studies, HBO2 should be considered for all cases of acute symptomatic CO poisoning. Hyperbaric oxygen is indicated for CO poisoning complicated by cyanide poisoning, often concomitantly with smoke inhalation.

  3. Electricity generation from carbon monoxide in a single chamber microbial fuel cell.

    PubMed

    Mehta, P; Hussain, A; Tartakovsky, B; Neburchilov, V; Raghavan, V; Wang, H; Guiot, S R

    2010-05-05

    Electricity production from carbon monoxide (CO) is demonstrated in a single chamber microbial fuel cell (MFC) with a CoTMPP-based air cathode. The MFC was inoculated with anaerobic sludge and continuously sparged with CO as a sole carbon source. Volumetric power output was maximized at a CO flow rate of 4.8LLR(-1)d(-1) reaching 6.4mWLR(-1). Several soluble and gaseous degradation products including hydrogen, methane, and acetate were detected, resulting in a relatively low apparent Coulombic efficiency of 8.7%. Tests also demonstrated electricity production from hydrogen and acetate with the highest and fastest increase in voltage exhibited after acetate injection. It is hypothesized that electricity generation in a CO-fed MFC is accomplished by a consortium of carboxydotrophic and carbon monoxide - tolerant anodophilic microorganisms. Crown Copyright © 2010. Published by Elsevier Inc. All rights reserved.

  4. Aerosol generation and measurement of multi-wall carbon nanotubes

    NASA Astrophysics Data System (ADS)

    Myojo, Toshihiko; Oyabu, Takako; Nishi, Kenichiro; Kadoya, Chikara; Tanaka, Isamu; Ono-Ogasawara, Mariko; Sakae, Hirokazu; Shirai, Tadashi

    2009-01-01

    Mass production of some kinds of carbon nanotubes (CNT) is now imminent, but little is known about the risk associated with their exposure. It is important to assess the propensity of the CNT to release particles into air for its risk assessment. In this study, we conducted aerosolization of a multi-walled CNT (MWCNT) to assess several aerosol measuring instruments. A Palas RBG-1000 aerosol generator applied mechanical stress to the MWCNT by a rotating brush at feed rates ranging from 2 to 20 mm/h, which the MWCNT was fed to a two-component fluidized bed. The fluidized bed aerosol generator was used to disperse the MWCNT aerosol once more. We monitored the generated MWCNT aerosol concentrations based on number, area, and mass using a condensation particle counter and nanoparticle surface area monitor. Also we quantified carbon mass in MWCNT aerosol samples by a carbon monitor. The shape of aerosolized MWCNT fibers was observed by a scanning electron microscope (SEM). The MWCNT was well dispersed by our system. We found isolated MWCNT fibers in the aerosols by SEM and the count median lengths of MWCNT fibers were 4-6 μm. The MWCNT was quantified by the carbon monitor with a modified condition based on the NIOSH analytical manual. The MWCNT aerosol concentration (EC mass base) was 4 mg/m3 at 2 mm/h in this study.

  5. AIRS Map of Carbon Monoxide Draped on Globe: Time Series from 8/1/2005 to 9/30/2005

    NASA Technical Reports Server (NTRS)

    2007-01-01

    [figure removed for brevity, see original site] Click on the image for movie of AIRS Map of Carbon Monoxide Draped on Globe

    Forest fires and agricultural burning create large amounts of carbon monoxide. AIRS provides daily global maps of carbon monoxide from space, allowing scientists to follow the global transport of this gas day-to-day. In this image sequence, carbon monoxide pollution from agricultural burning blooms repeatedly over the Amazonian basin. The gas is then transported across the Atlantic Ocean. Carbon monoxide pollution from fires in sub-Saharan Africa is also apparent.

    The Atmospheric Infrared Sounder Experiment, with its visible, infrared, and microwave detectors, provides a three-dimensional look at Earth's weather. Working in tandem, the three instruments can make simultaneous observations all the way down to the Earth's surface, even in the presence of heavy clouds. With more than 2,000 channels sensing different regions of the atmosphere, the system creates a global, 3-D map of atmospheric temperature and humidity and provides information on clouds, greenhouse gases, and many other atmospheric phenomena. The AIRS Infrared Sounder Experiment flies onboard NASA's Aqua spacecraft and is managed by NASA's Jet Propulsion Laboratory, Pasadena, Calif., under contract to NASA. JPL is a division of the California Institute of Technology in Pasadena.

  6. 40 CFR 52.2428 - Control Strategy: Carbon monoxide and ozone.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... ozone. 52.2428 Section 52.2428 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Control Strategy: Carbon monoxide and ozone. (a) Determination—EPA has determined that, as of November 5, 1997, the Richmond ozone nonattainment area, which consists of the counties of Chesterfield, Hanover...

  7. 40 CFR 52.2428 - Control Strategy: Carbon monoxide and ozone.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... ozone. 52.2428 Section 52.2428 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Control Strategy: Carbon monoxide and ozone. (a) Determination—EPA has determined that, as of November 5, 1997, the Richmond ozone nonattainment area, which consists of the counties of Chesterfield, Hanover...

  8. 40 CFR 52.2428 - Control Strategy: Carbon monoxide and ozone.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... ozone. 52.2428 Section 52.2428 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Control Strategy: Carbon monoxide and ozone. (a) Determination—EPA has determined that, as of November 5, 1997, the Richmond ozone nonattainment area, which consists of the counties of Chesterfield, Hanover...

  9. 40 CFR 52.2428 - Control Strategy: Carbon monoxide and ozone.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... ozone. 52.2428 Section 52.2428 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Control Strategy: Carbon monoxide and ozone. (a) Determination—EPA has determined that, as of November 5, 1997, the Richmond ozone nonattainment area, which consists of the counties of Chesterfield, Hanover...

  10. 40 CFR 52.2428 - Control Strategy: Carbon monoxide and ozone.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... ozone. 52.2428 Section 52.2428 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Control Strategy: Carbon monoxide and ozone. (a) Determination—EPA has determined that, as of November 5, 1997, the Richmond ozone nonattainment area, which consists of the counties of Chesterfield, Hanover...

  11. Postmortem and ex vivo carbon monoxide ventilation reduces injury in rat lungs transplanted from non-heart-beating donors.

    PubMed

    Dong, Boming; Stewart, Paul W; Egan, Thomas M

    2013-08-01

    We sought to determine whether ventilation of lungs after death in non-heart-beating donors with carbon monoxide during warm ischemia and ex vivo lung perfusion and after transplant would reduce ischemia-reperfusion injury and improve lung function. One hour after death, Sprague-Dawley rats were ventilated for another hour with 60% oxygen (control group) or 500 ppm carbon monoxide in 60% oxygen (CO-vent group; n=6/group). Then, lungs were flushed with 20 mL cold Perfadex, stored cold for 1 hour, then warmed to 37 °C in an ex vivo lung perfusion circuit perfused with Steen solution. At 37 °C, lungs were ventilated for 15 minutes with alveolar gas with or without 500 ppm carbon monoxide, then perfusion-cooled to 20 °C, flushed with cold Perfadex and stored cold for 2 hours. The left lung was transplanted using a modified cuff technique. Recipients were ventilated with 60% oxygen with or without carbon monoxide. One hour after transplant, we measured blood gases from the left pulmonary vein and aorta, and wet-to-dry ratio of both lungs. The RNA and protein extracted from graft lungs underwent real-time polymerase chain reaction and Western blotting, and measurement of cyclic guanosine monophosphate by enzyme-linked immunosorbent assay. Carbon monoxide ventilation begun 1 hour after death reduced wet/dry ratio after ex vivo lung perfusion. After transplantation, the carbon monoxide-ventilation group had better oxygenation; higher levels of tissue cyclic guanosine monophosphate, heme oxidase-1 expression, and p38 phosphorylation; reduced c-Jun N-terminal kinase phosphorylation; and reduced expression of interleukin-6 and interleukin-1β messenger RNA. Administration of carbon monoxide to the deceased donor and non-heart-beating donor lungs reduces ischemia-reperfusion injury in rat lungs transplanted from non-heart-beating donors. Therapy to the deceased donor via the airway may improve post-transplant lung function. Copyright © 2013 The American Association for

  12. Carbon Monoxide Poisoning: Death on Mount McKinley,

    DTIC Science & Technology

    1987-05-08

    Additionally, studies by Astrup(5) and Thomas(6) have reported decreased erythrocytic 2, 3- diphosphoglycerate (2, 3-DPG) concentrations with acute...Halebian, et al found no significant difference in measured 02 consumption or extraction between dogs subjected to CO poisoning vs nitrogen anoxia .(9...Astrup P: Intraerythrocytic 2,3- diphosphoglycerate and carbon monoxide exposure. Ann NY Acad Sci 1970;174:252-254. 6. Thomas MF, Penny DG: Hematologic

  13. 40 CFR 86.522-78 - Carbon monoxide analyzer calibration.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... performance on the most sensitive range. (2) Zero the carbon monoxide analyzer with either zero grade air or zero grade nitrogen. (3) Bubble a mixture of 3 percent CO2 in N2 through water at room temperature and... action. (Use of conditioning columns is one form of corrective action which may be taken.) (b) Initial...

  14. In situ gasification process for producing product gas enriched in carbon monoxide and hydrogen

    DOEpatents

    Capp, John P.; Bissett, Larry A.

    1978-01-01

    The present invention is directed to an in situ coal gasification process wherein the combustion zone within the underground coal bed is fed with air at increasing pressure to increase pressure and temperature in the combustion zone for forcing product gases and water naturally present in the coal bed into the coal bed surrounding the combustion zone. No outflow of combustion products occurs during the build-up of pressure and temperature in the combustion zone. After the coal bed reaches a temperature of about 2000.degree. F and a pressure in the range of about 100-200 psi above pore pressure the airflow is terminated and the outflow of the combustion products from the combustion zone is initiated. The CO.sub.2 containing gaseous products and the water bleed back into the combustion zone to react endothermically with the hot carbon of the combustion zone to produce a burnable gas with a relatively high hydrogen and carbon monoxide content. About 11 to 29 percent of the gas recovered from the combustion zone is carbon monoxide which is considerably better than the 4 to 10 percent carbon monoxide obtained by employing previously known coal gasification techniques.

  15. Modeling fire-induced smoke spread and carbon monoxide transportation in a long channel: Fire Dynamics Simulator comparisons with measured data.

    PubMed

    Hu, L H; Fong, N K; Yang, L Z; Chow, W K; Li, Y Z; Huo, R

    2007-02-09

    Smoke and toxic gases, such as carbon monoxide, are the most fatal factors in fires. This paper models fire-induced smoke spread and carbon monoxide transportation in an 88m long channel by Fire Dynamics Simulator (FDS) with large eddy simulation (LES). FDS is now a well-founded fire dynamics computational fluid dynamic (CFD) program, which was developed by National Institute of Standards and Technology (NIST). Two full scale experiments with fire sizes of 0.75 and 1.6MW were conducted in this channel to validate the program. The spread of the fire-induced smoke flow together with the smoke temperature distribution along the channel, and the carbon monoxide concentration at an assigned position were measured. The FDS simulation results were compared with experimental data with fairly good agreement demonstrated. The validation work is then extended to numerically study the carbon monoxide concentration distribution, both vertically and longitudinally, in this long channel. Results showed that carbon monoxide concentration increase linearly with the height above the floor and decreases exponentially with the distance away from the fire source.

  16. File Specification for the MERRA Aerosol Reanalysis (MERRAero): MODIS AOD Assimilation based on a MERRA Replay

    NASA Technical Reports Server (NTRS)

    Da Silva, A. M.; Randles, C. A.; Buchard, V.; Darmenov, A.; Colarco, P. R.; Govindaraju, R.

    2015-01-01

    This document describes the gridded output files produced by the Goddard Earth Observing System version 5 (GEOS-5) Goddard Aerosol Assimilation System (GAAS) from July 2002 through December 2014. The MERRA Aerosol Reanalysis (MERRAero) is produced with the hydrostatic version of the GEOS-5 Atmospheric Global Climate Model (AGCM). In addition to standard meteorological parameters (wind, temperature, moisture, surface pressure), this simulation includes 15 aerosol tracers (dust, sea-salt, sulfate, black and organic carbon), ozone, carbon monoxide and carbon dioxide. This model simulation is driven by prescribed sea-surface temperature and sea-ice, daily volcanic and biomass burning emissions, as well as high-resolution inventories of anthropogenic emission sources. Meteorology is replayed from the MERRA Reanalysis.

  17. Electron impact excitation of carbon monoxide in comet Hale-Bopp

    NASA Astrophysics Data System (ADS)

    Campbell, L.; Brunger, M. J.

    2009-02-01

    The fourth positive emissions of carbon monoxide in the coma of comet Hale-Bopp have been assumed to be due mainly to fluorescence induced by sunlight. Based on this assumption they were used to deduce the abundance of carbon monoxide in the comet, giving a value higher than in other comets. Emissions produced by electron impact excitation of CO were not considered. Recent measurements and theoretical calculations of integral cross sections for electron impact excitation of CO allow the contribution of electron impact to be calculated, giving about 40% of the total. This implies that the abundance of CO in the outer coma of comet Hale-Bopp was only 60% of that previously deduced. However, as the high proportion of CO in comet Hale-Bopp was also seen in some other measurements, alternative explanations are considered. The method of calculation is tested by successfully predicting the O I emission at 1356 Å, supporting the belief that this line is due to electron impact excitation.

  18. Reaction engineering for materials processing in space: Reduction of ilmenite by hydrogen and carbon monoxide

    NASA Technical Reports Server (NTRS)

    Zhao, Y.; Shadman, F.

    1991-01-01

    Oxygen is a consumable material which needs to be produced continuously in most space missions. Its use for propulsion as well as life support makes oxygen one of the largest volume chemicals to be produced in space. Production of oxygen from lunar materials is of particular interest and is very attractive possibility. The kinetics and mechanism of reduction of ilmenite by carbon monoxide and hydrogen at 800 to 1100 C were investigated. The temporal profiles of conversion for carbon monoxide have a sigmoidal shape and indicate the presence of three different stages (induction, acceleration, and deceleration) during the reduction reaction. The apparent activation energy decreases from 18 kcal/mole at 10 percent conversion to 10 kcal/mole at 50 percent conversion. The reaction is first order with respect to carbon monoxide under the experimental conditions studied. Both SEM and EDX analysis show that the diffusion of Fe product away from the reaction front and through the TiO2 phase, followed by the nucleation and growth of a separate Fe phase are important steps affecting the process kinetics. The results from hydrogen reduction show that the mechanism of ilmenite reduction by hydrogen is similar to that by carbon monoxide. However, the titanium dioxide can be further reduced by hydrogen at 800 to 1000 C. The detailed comparison and theoretical modeling of both reduction processes is presented.

  19. Unique case of fatal carbon monoxide poisoning in the absence of a combustible fossil fuel.

    PubMed

    Morgan, D R; Poon, P; Titley, J; Jagger, S F; Rutty, G N

    2001-09-01

    A 37-year-old man died as a result of exposure to carbon monoxide within an apartment. An investigation of the apartment showed no gas appliances or gas supply to the apartment and no evidence of any combustion event to any part of the apartment or roof space. Inhalation of dichloromethane was excluded. Heating to the apartment was found to be via an electrical storage heater, the examination of which revealed that the cast-iron core and insulating material showed evidence of heat damage with significant areas devoid of carbon. This electric storage heater is hypothesized to be the source of carbon for the fatal production of carbon monoxide within the apartment.

  20. 40 CFR 52.1627 - Control strategy and regulations: Carbon monoxide.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 4 2014-07-01 2014-07-01 false Control strategy and regulations: Carbon monoxide. 52.1627 Section 52.1627 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS (CONTINUED) New Mexico § 52.1627 Control strategy and regulations:...

  1. 40 CFR 52.1627 - Control strategy and regulations: Carbon monoxide.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 4 2013-07-01 2013-07-01 false Control strategy and regulations: Carbon monoxide. 52.1627 Section 52.1627 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS (CONTINUED) New Mexico § 52.1627 Control strategy and regulations:...

  2. Revised Evaluation of Health Effects Associated with Carbon Monoxide Exposure: An Addendum to the 1979 U.S. EPA Air Quality Criteria Document for Carbon Monoxide (1984)

    EPA Science Inventory

    The addendum re-evaluates the scientific data base concerning health effects associated with exposure to carbon monoxide (CO) at ambient or near ambient levels by providing: (1) a concise summary of key health effects information pertaining to relatively low-level CO exposure; an...

  3. Inhalation toxicology. IX., Times-to-incapacitation for rats exposed to carbon monoxide alone, to hydrogen cyanide alone, and to mixtures of carbon monoxide and hydrogen cyanide.

    DOT National Transportation Integrated Search

    1989-01-01

    Laboratory rats were exposed to experimental atmospheres that contained a) carbon monoxide in air, b) hydrogen cyanide in air, and c) mixtures of CO and HCN in air. The toxic potency of each of the three types of environments was evaluated toxico-kin...

  4. Supply Ventilation and Prevention of Carbon Monoxide (II) Ingress into Building Premises

    NASA Astrophysics Data System (ADS)

    Litvinova, N. A.

    2017-11-01

    The article contains the relationships of carbon monoxide (II) concentration versus height-above-ground near buildings derived based on results of studies. The results of studies are crucial in preventing external pollutants ingress into a ventilation system. Being generated by external emission sources, such as motor vehicles and city heating plants, carbon monoxide (II) enters the premises during operation of a supply ventilation system. Fresh air nomographic charts were drawn to select the height of a fresh air intake into the ventilation system. Nomographic charts take into account external sources. The selected emission sources are located at various levels above ground relative to the building. The recommendations allow designing supply ventilation taking into account the quality of ambient air through the whole building height.

  5. Mechanism of Ethylene and Carbon Monoxide Production by Septoria musiva

    Treesearch

    Susan K. Brown-Skrobot; Lewis R. Brown; Ted H. Filer

    1985-01-01

    S. musiva, a causative agent of premature defoliation of cottonwood trees, has been shown previously to produce ethylene and carbon monoxide (CO) on media containing glucose, methionine, and iron. Chemical analyses have shown that all three substances are present in the cottonwood leaves. Of seven carbohydrates tested, none supported the production...

  6. Carbon monoxide toxicity. January 1978-March 1989 (Citations from the Life Sciences Collection data base). Report for January 1978-March 1989

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    This bibliography contains citations concerning the mechanism and clinical manifestations of carbon monoxide exposure, including the effects on the liver, cardiovascular, and nervous systems. Topics include carbon monoxide binding affinity studies with hemoglobin, measurement of carboxyhemoglobin in humans and various animal species, carbon monoxide levels as related to tobacco and marijuana smoke, occupational exposure and the NIOSH biological exposure index, symptomology and percent of blood CO, and intrauterine exposure. Air pollution, tobacco smoking, and occupational exposure are discussed as primary sources of carbon monoxide exposure. The effects of cigarette smoking on fetal development and health are excluded and examined inmore » a separate bibliography. (This updated bibliography contains 221 citations, 19 of which are new entries to the previous edition.)« less

  7. Accidental Carbon Monoxide Poisoning While Driving: A Case Report With Review of the Literature.

    PubMed

    Fisher-Hubbard, Amanda O; Appleford, Colin; Kesha, Kilak; Schmidt, Carl J; Gupta, Avneesh

    2018-05-16

    Carbon monoxide (CO) is the cause of a significant percentage of fatal poisonings in many countries. It is known that fatalities resulting from CO poisoning are underreported and/or misclassified. Carbon monoxide exposure while driving can occur due to faulty exhaust systems, defective ventilation systems, emission from other vehicles, and even cigarette smoking. We report the case of a 23-year-old woman who was involved in a low-speed motor vehicle collision and was found unresponsive in her vehicle due to CO poisoning. A review of the literature revealed rare vehicle-related accidental CO poisonings.

  8. Acute Compartment Syndrome Which Causes Rhabdomyolysis by Carbon Monoxide Poisoning and Sciatic Nerve Injury Associated with It: A Case Report.

    PubMed

    Ji, Jung-Woo

    2017-09-01

    Rhabdomyolysis is most frequently caused by soft tissue injury with trauma to the extremities. Non-traumatic rhabdomyolysis may be caused by alcohol or drug abuse, infection, collagen disease, or intensive exercise, but incidence is low. In particular, rhabdomyolysis resulting from carbon monoxide poisoning is especially rare. If caught before death, carbon monoxide poisoning has been shown to cause severe muscle necrosis and severe muscle damage leading to acute renal failure. In cases of carbon-monoxide-induced rhabdomyolsis leading to acute compartment syndrome in the buttocks and sciatic nerve injury are rare. We have experience treating patients with acute compartment syndrome due to rhabdomyolysis following carbon monoxide poisoning. We report the characteristic features of muscle necrosis observed during a decompression operation and magnetic resonance imaging findings with a one-year follow-up in addition to a review of the literature.

  9. Methanation of gas streams containing carbon monoxide and hydrogen

    DOEpatents

    Frost, Albert C.

    1983-01-01

    Carbon monoxide-containing gas streams having a relatively high concentration of hydrogen are pretreated so as to remove the hydrogen in a recoverable form for use in the second step of a cyclic, essentially two-step process for the production of methane. The thus-treated streams are then passed over a catalyst to deposit a surface layer of active surface carbon thereon essentially without the formation of inactive coke. This active carbon is reacted with said hydrogen removed from the feed gas stream to form methane. The utilization of the CO in the feed gas stream is appreciably increased, enhancing the overall process for the production of relatively pure, low-cost methane from CO-containing waste gas streams.

  10. A Computer Model for Evaluating the Effects on Fighting Vehicle Crewmembers of Exposure to Carbon Monoxide Emissions.

    DTIC Science & Technology

    1980-01-01

    SUPPLEMENTARY NOTES Is. KEY WORDS (Continue on reverse ede If neceseay id Identify by block number) Carbon Monoxide (CO) Computer Program Carboxyhemoglobin ...several researchers, which predicts the instantaneous amount of carboxyhemoglobin (COHb) in the blood of a person based upon the amount of carbon monoxide...developed from an empirical equation (derived from reference I and detailed in reference 3) which predicts the amount of carboxyhemoglobin (COHb) in

  11. Integrated Science Assessment (ISA) for Carbon Monoxide (Final Report, Jan 2010)

    EPA Science Inventory

    EPA announced the availability of the final report, Integrated Science Assessment (ISA) for Carbon Monoxide (CO). This report is EPA’s latest evaluation of the scientific literature on the potential human health and welfare effects associated with ambient exposures to CO...

  12. LOW-LEVEL CARBON MONOXIDE EXPOSURE AND WORK CAPACITY AT 1600 METERS

    EPA Science Inventory

    At sea level, low-level carbon monoxide (CO) exposure impairs exercise performance. To determine if altitude residence at 1600 m augments this CO effect, two studies of graded treadmill work capacity were done. The Initial Study investigated nine, non-smoking male subjects breath...

  13. Carbon monoxide and oxygen combustion experiments: A demonstration of Mars in situ propellants

    NASA Technical Reports Server (NTRS)

    Linne, Diane L.

    1991-01-01

    The feasibility of using carbon monoxide and oxygen as rocket propellants was examined both experimentally and theoretically. The steady-state combustion of carbon monoxide and oxygen was demonstrated for the first time in a subscale rocket engine. Measurements of experimental characteristic velocity, vacuum specific impulse, and thrust coefficient efficiency were obtained over a mixture ratio range of 0.30 to 2.0 and a chamber pressures of 1070 and 530 kPa. The theoretical performance of the propellant combination was studied parametrically over the same mixture ratio range. In addition to one dimensional ideal performance predictions, various performance reduction mechanisms were also modeled, including finite-rate kinetic reactions, two-dimensional divergence effects and viscous boundary layer effects.

  14. Carbon monoxide detector. [electrochemical gas detector for spacecraft use

    NASA Technical Reports Server (NTRS)

    Holleck, G. L.; Bradspies, J. L.; Brummer, S. B.; Nelsen, L. L.

    1973-01-01

    A sensitive carbon monoxide detector, developed specifically for spacecraft use, is described. An instrument range of 0 to 60 ppm CO in air was devised. The fuel cell type detector is used as a highly sensitive electrolysis cell for electrochemically detecting gases. The concept of an electrochemical CO detector is discussed and the CO oxidation behavior in phosphoric and sulfuric acid electrolytes is reported.

  15. Table of Historical Carbon Monoxide (CO) National Ambient Air Quality Standards (NAAQS)

    EPA Pesticide Factsheets

    See the history of limits to the level of carbon monoxide (CO) in ambient air, set through the NAAQS review and rulemaking process under the Clean Air Act. This includes both primary and secondary standards.

  16. CARBON MONOXIDE REVERSIBLY DISRUPTS IRON HOMEOSTATIS AND RESPIRATORY EPITHELIAL CELLS FUNCTION

    EPA Science Inventory

    Iron dissociation from heme is a major factor in iron metabolism and cellular concentrations of the metal correlate inversely with the expression of heme oxygenase (HO). We tested the hypothesis that 1) exposure to a product of HO, carbon monoxide (CO), disturbs iron homeostas...

  17. [Risk of underestimating blood carbon monoxide by certain analytic methods].

    PubMed

    Gourlain, H; Laforge, M; Buneaux, F; Galliot-Guilley, M

    1999-01-30

    Study the effect of delay to assay on the measurement of carboxyhemoglobin (HbCO) in total blood samples. Carbon monoxide (CO) and carboxyhemoglobin were measured on 75 blood samples drawn from healthy subjects (smokers and non smokers) and in subjects with carbon monoxide (CO) poisoning. Blood samples were drawn on lithium heparinate in perfectly closed tubes with no head space and stored at 4 infinity C until assay. The samples were pooled into 4 classes for 4 delays to assay: immediate, less than one hour, 3 hours, 12 hours. Infrared spectrometry was used to assay CO and order 4 and 5 derived spectrophotometry using CO-oximeters (AVL 912, IL 482, Corning 270, Radiometer OSM 3, Radiometer ABL 520) for HbCO. Regression lines for CO versus HbCO suggested that oxycarbonemia was underestimated using techniques measuring HbCO. This underestimation varied from 3 to 40% for delays to assay of 0 to 3 hours. Clinicians should be aware that the underestimation in oxycarbonemia related to HbCO assays is sensitive to delay to assay.

  18. Gas filter radiometer for carbon monoxide measurements during the 1979 Summer Monsoon Experiment (MONEX)

    NASA Technical Reports Server (NTRS)

    Reichle, H. G., Jr.; Wallio, H. A.; Casas, J. C.; Condon, E. P.

    1986-01-01

    The instrumental and data-reduction techniques used in obtaining remote measurements of carbon monoxide during the 1979 Summer Monsoon Experiment are described. The form of the signal function (the variation of signal with altitude) and the impact of variations in the vertical distribution of carbon monoxide are discussed. Estimates of the experimental accuracy are made both by assessment of error sources through the use of numerical simulations and by comparison with concurrent measurements made by means of gas chromatography. It is found that the radiometric measurements tend to be about 9 percent lower than the direct measurements and to have a precision of about 8 percent.

  19. Carbon monoxide toxicity. April 1978-November 1989 (A Bibliography from the Life Sciences Collection data base). Report for April 1978-November 1989

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    This bibliography contains citations concerning the mechanism and clinical manifestations of carbon monoxide exposure, including the effects on the liver, cardiovascular, and nervous systems. Topics include carbon monoxide binding affinity studies with hemoglobin, measurement of carboxyhemoglobin in humans and various animal species, carbon monoxide levels as related to tobacco and marijuana smoke, occupational exposure and the NIOSH biological exposure index, symptomology and percent of blood CO, and intrauterine exposure. Air pollution, tobacco smoking, and occupational exposure are discussed as primary sources of carbon monoxide exposure. The effects of cigarette smoking on fetal development and health are excluded and examined inmore » a separate bibliography. (This updated bibliography contains 237 citations, 16 of which are new entries to the previous edition.)« less

  20. Connections between Concepts Revealed by the Electronic Structure of Carbon Monoxide

    ERIC Educational Resources Information Center

    Liu, Ying; Liu, Bihui; Liu, Yue; Drew, Michael G. B.

    2012-01-01

    Different models for the electronic structure of carbon monoxide are suggested in influential textbooks. Therefore, this electronic structure offers an interesting subject in teaching because it can be used as an example to relate seemingly conflicting concepts. Understanding the connections between ostensibly different methods and between…

  1. Reduced tar, nicotine, and carbon monoxide exposure while smoking ultralow- but not low-yield cigarettes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Benowitz, N.L.; Jacob, P. III; Yu, L.

    An unresolved public health issue is whether some modern cigarettes are less hazardous than other and whether patients who cannot stop smoking should be advised to switch to lower-yield cigarettes. The authors studied tar (estimated by urine mutagenicity), nicotine, and carbon monoxide exposure in habitual smokers switched from their usual brand to high- (15 mg of tar), low- (5 mg of tar), or ultralow-yield (1 mg of tar) cigarettes. There were no differences in exposure comparing high- or low-yield cigarettes, but tar and nicotine exposures were reduced by 49% and 56%, respectively, and carbon monoxide exposure by 36% while smokingmore » ultralow-yield cigarettes. Similarly, in 248 subjects smoking their self-selected brand, nicotine intake, estimated by blood concentrations of its metabolite continine, was 40% lower in those who smoked ultralow but no different in those smoking higher yields of cigarettes. The data indicate that ultralow-yield cigarettes do deliver substantial doses of tar, nicotine, and carbon monoxide, but that exposure are considerably less than for other cigarettes.« less

  2. Suicidal carbon monoxide poisoning using a gas-powered generator.

    PubMed

    Blässer, Katharina; Tatschner, Thomas; Bohnert, Michael

    2014-03-01

    The presented case deals with an unusual suicide by carbon monoxide poisoning. In a car parked in a highway rest area, the body of a middle-aged man was found. In the open trunk of the car there was a gas-powered generator which was switched on, but no longer running. The tank was three quarters full. At autopsy, bright-red livores, cherry-pink fingernails, cherry-red blood and salmon-red skeletal musculature were found. According to the toxicological analysis performed during autopsy, the COHb content in the corpse blood was 68%. To reconstruct the event, the emergency generator was started again in the man's car. By means of measuring probes placed in the interior of the car, carbon monoxide, carbon dioxide and oxygen were measured and recorded in a concentration-time curve; the concentration of cyanide was measured at the end of the experiment. The lower explosion limit of 500 ppm CO was reached after 30s already. For technical reasons, no further values could be recorded. After about 14 min the engine started stuttering with approximately 14 vol.% of oxygen in the air, but continued to run at a lower speed until the experiment was stopped after 25 min. The final concentration of cyanide was 7.5 ppm. In view of the rapid CO increase in the interior of the vehicle it is to be assumed that the victim lost consciousness very fast. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  3. Incidence and causes of carbon monoxide intoxication: results of an epidemiologic survey in a French department.

    PubMed

    Gajdos, P; Conso, F; Korach, J M; Chevret, S; Raphael, J C; Pasteyer, J; Elkharrat, D; Lanata, E; Geronimi, J L; Chastang, C

    1991-01-01

    The purpose of this study was to estimate the incidence, mortality, and causes of carbon monoxide intoxications in France. A survey was conducted in the department of the Hauts-de-Seine, which is representative of the French population. Data were collected through a headquarters that had direct contact with all department emergency organizations and to a technical laboratory. During the 3-y study, 735 cases that were related to 291 events were reported. Thirty-six patients died. The average incidence of carbon monoxide intoxications was 17.5 per 100,000 inhabitants. Poisoning was caused by fires in 36 events and by car exhausts in 12. For the remaining events, causes were determined as follows for 196: water heaters (57%), boiler (20.5%), coal stove (9%), brazier (4%), cooker (2%), heating device (1.5%), and miscellaneous (6%). The main mechanisms of intoxication were a defective device, poor ventilation, or poor evacuation of combustion gases. Carbon monoxide intoxication occurs frequently in France, and preventive actions are warranted.

  4. Thermal device and method for production of carbon monoxide and hydrogen by thermal dissociation of hydrocarbon gases

    DOEpatents

    Detering, Brent A.; Kong, Peter C.

    2001-01-01

    Carbon monoxide is produced in a fast quench reactor. The production of carbon monoxide includes injecting carbon dioxide and some air into a reactor chamber having a high temperature at its inlet and a rapidly expanding a reactant stream, such as a restrictive convergent-divergent nozzle at its outlet end. Carbon dioxide and other reactants such as methane and other low molecular weight hydrocarbons are injected into the reactor chamber. Other gas may be added at different stages in the process to form a desired end product and prevent back reactions. The resulting heated gaseous stream is then rapidly cooled by expansion of the gaseous stream.

  5. Characterization of Ambient Black Carbon Aerosols

    NASA Astrophysics Data System (ADS)

    Zhang, R.; Levy, M. E.; Zheng, J.; Molina, L. T.

    2013-12-01

    Because of the strong absorption over a broad range of the electromagnetic spectra, black carbon (BC) is a key short-lived climate forcer, which contributes significantly to climate change by direct radiative forcing and is the second most important component causing global warming after carbon dioxide. The impact of BC on the radiative forcing of the Earth-Atmosphere system is highly dependent of the particle properties. In this presentation, emphasis will be placed on characterizing BC containing aerosols in at the California-Mexico border to obtain a greater understanding of the atmospheric aging and properties of ambient BC aerosols. A comprehensive set of directly measured aerosol properties, including the particle size distribution, effective density, hygroscopicity, volatility, and several optical properties, will be discussed to quantify the mixing state and composition of ambient particles. In Tijuana, Mexico, submicron aerosols are strongly influenced by vehicle emissions; subsequently, the BC concentration in Tijuana is considerably higher than most US cities with an average BC concentration of 2.71 × 2.65 g cm-3. BC accounts for 24.75 % × 9.44 of the total submicron concentration on average, but periodically accounts for over 50%. This high concentration of BC strongly influences many observed aerosol properties such as single scattering albedo, hygroscopicity, effective density, and volatility.

  6. Separation of Carbon Monoxide and Carbon Dioxide for Mars ISRU

    NASA Technical Reports Server (NTRS)

    Walton, Krista S.; LeVan, M. Douglas

    2004-01-01

    The atmosphere of Mars has many resources that can be processed to produce things such as oxygen, fuel, buffer gas, and water for support of human exploration missions. Successful manipulation of these resources is crucial for safe, cost-effective, and self-sufficient long-term human exploration of Mars. In our research, we are developing enabling technologies that require fundamental knowledge of adsorptive gas storage and separation processes. In particular, we are designing and constructing an innovative, low mass, low power separation device to recover carbon dioxide and carbon monoxide for Mars ISRU (in-situ resource utilization). The technology has broad implications for gas storage and separations for gas-solid systems that are ideally suited for reduced gravitational environments. This paper describes our separation process design and experimental procedures and reports results for the separation of CO2 and CO by a four-step adsorption cycle.

  7. Distribution of anaerobic carbon monoxide dehydrogenase genes in deep subseafloor sediments.

    PubMed

    Hoshino, T; Inagaki, F

    2017-05-01

    Carbon monoxide (CO) is the simplest oxocarbon generated by the decomposition of organic compounds, and it is expected to be in marine sediments in substantial amounts. However, the availability of CO in the deep subseafloor sedimentary biosphere is largely unknown even though anaerobic oxidation of CO is a thermodynamically favourable reaction that possibly occurs with sulphate reduction, methanogenesis, acetogenesis and hydrogenesis. In this study, we surveyed for the first time the distribution of the CO dehydrogenase gene (cooS), which encodes the catalytic beta subunit of anaerobic CO dehydrogenase (CODH), in subseafloor sediment-core samples from the eastern flank of the Juan de Fuca Ridge, Mars-Ursa Basin, Kumano Basin, and off the Shimokita Peninsula, Japan, during Integrated Ocean Drilling Program (IODP) Expeditions 301, 308 and 315 and the D/V Chikyu shakedown cruise CK06-06, respectively. Our results show the occurrence of diverse cooS genes from the seafloor down to about 390 m below the seafloor, suggesting that microbial communities have metabolic functions to utilize CO in anoxic microbial ecosystems beneath the ocean floor, and that the microbial community potentially responsible for anaerobic CO oxidation differs in accordance with possible energy-yielding metabolic reactions in the deep subseafloor sedimentary biosphere. Little is known about the microbial community associated with carbon monoxide (CO) in the deep subseafloor. This study is the first survey of a functional gene encoding anaerobic carbon monoxide dehydrogenase (CODH). The widespread occurrence of previously undiscovered CO dehydrogenase genes (cooS) suggests that diverse micro-organisms are capable of anaerobic oxidation of CO in the deep subseafloor sedimentary biosphere. © 2017 The Society for Applied Microbiology.

  8. SEASONAL SOIL FLUXES OF CARBON MONOXIDE IN BURNED AND UNBURNED BRAZILIAN SAVANNAS

    EPA Science Inventory

    Soil-atmosphere fluxes of carbon monoxide (CO) were measured from September 1999 through November 2000 in savanna areas in central Brazil (Cerrado) under different fire regimes using transparent and opaque static chambers. Studies focused on two vegetation types, cerrado stricto...

  9. High carbon monoxide levels measured in enclosed skating rinks

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Spengler, J.D.; Stone, K.R.; Lilley, F.W.

    Carbon monoxide (CO) levels were measured in enclosed skating rinks in the Boston area. The 1 hr National Ambient Air Quality Standard of 35 ppm was exceeded in 82% of the sampled hours. In a separate study, alveolar breath samples were taken of 12 Harvard hockey players, indicating a fivefold increase in carboxyhemoglobin levels after 93 min of exercise in air with a relatively low 25 ppm CO concentration. This paper demonstrates that exercising athletes are incurring physiologically dangerous levels of carboxyhemoglobin when performing in legal ambient air concentrations of CO-25 ppm, and concentrations of the poisonous gas in manymore » indoor skating rinks regularly exceed the national ambient standards by as much as 300%. It is suggested that the Clean Air Act should be amended to include indoor public exposure to at least the criteria pollutants of carbon monoxide, sulfur dioxide, nitrogen dioxide, and suspended particulates. The U.S. Environmental Protection Agency should require revisions in State Implementation Plans to ensure state responsibility for public air pollution exposures indoors. Finally, it is suggested that rink maintenance machinery be redesigned to reduce noxious output by shifting to electrical motors, by upgrading pollution control equipment, or by routine use of ventilation equipment.« less

  10. Modelling of Carbon Monoxide Air Pollution in Larg Cities by Evaluetion of Spectral LANDSAT8 Images

    NASA Astrophysics Data System (ADS)

    Hamzelo, M.; Gharagozlou, A.; Sadeghian, S.; Baikpour, S. H.; Rajabi, A.

    2015-12-01

    Air pollution in large cities is one of the major problems that resolve and reduce it need multiple applications and environmental management. Of The main sources of this pollution is industrial activities, urban and transport that enter large amounts of contaminants into the air and reduces its quality. With Variety of pollutants and high volume manufacturing, local distribution of manufacturing centers, Testing and measuring emissions is difficult. Substances such as carbon monoxide, sulfur dioxide, and unburned hydrocarbons and lead compounds are substances that cause air pollution and carbon monoxide is most important. Today, data exchange systems, processing, analysis and modeling is of important pillars of management system and air quality control. In this study, using the spectral signature of carbon monoxide gas as the most efficient gas pollution LANDSAT8 images in order that have better spatial resolution than appropriate spectral bands and weather meters،SAM classification algorithm and Geographic Information System (GIS ), spatial distribution of carbon monoxide gas in Tehran over a period of one year from the beginning of 2014 until the beginning of 2015 at 11 map have modeled and then to the model valuation ،created maps were compared with the map provided by the Tehran quality comparison air company. Compare involved plans did with the error matrix and results in 4 types of care; overall, producer, user and kappa coefficient was investigated. Results of average accuracy were about than 80%, which indicates the fit method and data used for modeling.

  11. Carbon Monoxide Isotopes: On the Trail of Galactic Chemical Evolution

    NASA Technical Reports Server (NTRS)

    Langer, W.

    1995-01-01

    From the early days of the discovery of radio emission from carbon monoxide it was realized that it offered unusual potential for under- standing the chemical evolution of the Galaxy and external galaxies through measurements of molecular isotopes. These results bear on stellar nucleosynthesis, star formation, and gases in the interstellar medium. Progress in isotopic radio measurements will be reviewed.

  12. [Cerebellar Infarction After Carbon Monoxide Poisoning and Hyperbaric Oxygen Therapy].

    PubMed

    Wick, Matthias; Schneiker, André; Bele, Sylvia; Pawlik, Michael; Meyringer, Helmut; Graf, Bernhard; Wendl, Christina; Kieninger, Martin

    2017-06-01

    We report on a patient who developed a space-occupying cerebellar infarction with occlusive hydrocephalus after a poisoning with carbon monoxide with the intention to commit suicide. A neurosurgical and intensive care therapy were needed. The patient's survival without severe neurological deficits could be secured due to the early detection of the intracerebral lesions. Georg Thieme Verlag KG Stuttgart · New York.

  13. Exposure and Emissions Monitoring during Carbon Nanofiber Production—Part I: Elemental Carbon and Iron–Soot Aerosols

    PubMed Central

    Birch, M. Eileen; Ku, Bon-Ki; Evans, Douglas E.; Ruda-Eberenz, Toni A.

    2015-01-01

    Production of carbon nanofibers and nanotubes (CNFs/CNTs) and their composite products is increasing globally. High volume production may increase the exposure risks for workers who handle these materials. Though health effects data for CNFs/CNTs are limited, some studies raise serious health concerns. Given the uncertainty about their potential hazards, there is an immediate need for toxicity data and field studies to assess exposure to CNFs/CNTs. An extensive study was conducted at a facility that manufactures and processes CNFs. Filter, sorbent, cascade impactor, bulk, and microscopy samples, combined with direct-reading instruments, provided complementary information on air contaminants. Samples were analyzed for organic carbon (OC) and elemental carbon (EC), metals, and polycyclic aromatic hydrocarbons (PAHs), with EC as a measure of CNFs. Transmission electron microscopy with energy-dispersive X-ray spectroscopy also was applied. Fine/ultrafine iron-rich soot, PAHs, and carbon monoxide were production byproducts. Direct-reading instrument results were reported previously [Evans DE et al. (Aerosol monitoring during carbon nanofiber production: mobile direct-reading sampling. Ann Occup Hyg 2010;54:514–31.)] Results for time-integrated samples are reported as companion papers in this Issue. OC and EC, metals, and microscopy results are reported here, in Part I, while results for PAHs are reported in Part II [Birch ME. (Exposure and Emissions Monitoring during Carbon Nanofiber Production—Part II: Polycyclic Aromatic Hydrocarbons. Ann. Occup. Hyg 2011; 55: 1037–47.)]. Respirable EC area concentrations inside the facility were about 6–68 times higher than outdoors, while personal breathing zone samples were up to 170 times higher. PMID:21965464

  14. The Future of Carbon Monoxide Measurements from Space

    NASA Astrophysics Data System (ADS)

    Drummond, J.

    It is now over 20 years since the Measurements of Air Pollution from Space MAPS instrument made the first measurements of tropospheric carbon monoxide from the shuttle Since that time a number of instruments have flown including the Measurements Of Pollution In The Troposphere MOPITT Tropospheric Emission Spectrometer TES and SCanning Imaging Absorption SpectroMeter for Atmospheric CHartographY SCIAMCHY to name only three of many Each of these instruments has a unique observing method and unique mission characteristics It is accepted that measurements of carbon monoxide provide a useful proxy of the pollution of the troposphere and contribute significantly to studies of various phenomena in the atmosphere and atmosphere-surface interactions These measurements should therefore be continued -- but in what form Technology has progresses significantly since the current generation of instruments was designed and our ability to interpret the data from such instrumentation has likewise expanded It is therefore fruitful to consider what is the best set of measurements that can be made which parameters should be emphasized and which compromised on the way to the next generation of sensors The Measurements of Air Pollution Levels in the Environment MAPLE instrument is a study financed by the Canadian Space Agency to design a next-generation instrument and since instrument spacecraft and mission are now intimately linked a consideration of the whole mission is appropriate This talk will outline some potential developments in the hardware

  15. Aerosol carbon isotope composition over Baltic Sea

    NASA Astrophysics Data System (ADS)

    Garbaras, Andrius; Pabedinskas, Algirdas; Masalaite, Agne; Petelski, Tomasz; Gorokhova, Elena; Sapolaite, Justina; Ezerinskis, Zilvinas; Remeikis, Vidmantas

    2017-04-01

    Particulate carbonaceous matter is significant contributor to ambient particulate matter originating from intervening sources which contribution is difficult to quantify due to source diversity, chemical complexity and processes during atmospheric transport. Carbon isotope analysis can be extremely useful in source apportionment of organic matter due to the unique isotopic signatures associated with anthropocentric (fossil fuel), continental (terrestrial plants) and marine sources, and is particularly effective when these sources are mixed (Ceburnis et al., 2011;Ceburnis et al., 2016). We will present the isotope ratio measurement results of aerosol collected during the cruise in the Baltic Sea. Sampling campaign of PM10 and size segregated aerosol particles was performed on the R/V "Oceania" in October 2015. Air mass back trajectories were prevailing both from the continental and marine areas during the sampling period. The total carbon concentration varied from 1 µg/m3 to 8 µg/m3. Two end members (δ13C = -25‰ and δ13C = -28 ‰ ) were established from the total stable carbon isotope analysis in PM10 fraction. δ13C analysis in size segregated aerosol particles revealed δ13C values being highest in the 1 - 2.5 µm range (δ13C = -24.9 ‰ ) during continental transport, while lowest TC δ13C values (δ13C ≈ -27 ‰ ) were detected in the size range D50 <1 µm during stormy weather when air mass trajectory prevailed from the western direction. These measurements revealed that simplified isotope mixing model can not be applied for the aerosol source apportionment (Masalaite et al., 2015) in the perturbed marine environment. Additionally, concentration of bacteria and fungi were measured in size segregated and PM10 aerosol fraction. We were able to relate aerosol source δ13C end members with the abundance of bacteria and fungi over Baltic Sea combining air mass trajectories, stable isotope data, fungi and bacteria concentrations. Ceburnis, D., Garbaras, A

  16. The Carbon Monoxide Tape Recorder

    NASA Technical Reports Server (NTRS)

    Schoeberl, M. R.; Duncan, B. N.; Douglass, A. R.; Waters, J.; Livesey, N.; Read, W.; Filipiak, M.

    2006-01-01

    Using Aura MLS data we have identified the stratospheric tape recorder in carbon monoxide (CO). Unlike the water vapor tape recorder, which is controlled by upper troposphere processes, the CO tape recorder is linked to seasonal biomass burning. Since CO has a lifetime of only a few months, the CO tape recorder barely extends above 20 km. The tape head for CO appears to be close to 360K near the same location as the water vapor tape head [Read et al, 20041. Both tape heads are below the equatorial cold point tropopause but above the base of the tropical tropopause layer. The tape recorder signal becomes more distinct from 360K to 380K suggesting that convective detrainment of plays a decreasingly important role with altitude. The Global Modeling Initiative chemical transport model forced by the climatology of biomass burning reproduces the CO tape recorder.

  17. High Resolution Spectra of Carbon Monoxide, Propane and Ammonia for Atmospheric Remote Sensing

    NASA Astrophysics Data System (ADS)

    Beale, Christopher Andrew

    Spectroscopy is a critical tool for analyzing atmospheric data. Identification of atmospheric parameters such as temperature, pressure and the existence and concentrations of constituent gases via remote sensing techniques are only possible with spectroscopic data. These form the basis of model atmospheres which may be compared to observations to determine such parameters. To this end, this dissertation explores the spectroscopy of three molecules: ammonia, propane and carbon monoxide. Infrared spectra have been recorded for ammonia in the region 2400-9000 cm-1. These spectra were recorded at elevated temperatures (from 293-973 K) using a Fourier Transform Spectrometer (FTS). Comparison between the spectra recorded at different temperatures yielded experimental lower state energies. These spectra resulted in the measurement of roughly 30000 lines and about 3000 quantum assignments. In addition spectra of propane were recorded at elevated temperatures (296-700 K) using an FTS. Atmospheres with high temperatures require molecular data at appropriate conditions. This dissertation describes collection of such data and the potential application to atmospheres in our solar system, such as auroral regions in Jupiter, to those of planets orbiting around other stars and cool sub-stellar objects known as brown dwarfs. The spectra of propane and ammonia provide the highest resolution and most complete experimental study of these gases in their respective spectral regions at elevated temperatures. Detection of ammonia in an exoplanet or detection of propane in the atmosphere of Jupiter will most likely rely on the work presented here. The best laboratory that we have to study atmospheres is our own planet. The same techniques that are applied to these alien atmospheres originated on Earth. As such it is appropriate to discuss remote sensing of our own atmosphere. This idea is explored through analysis of spectroscopic data recorded by an FTS on the Atmospheric Chemistry

  18. EFFECT OF LOW LEVEL CARBON MONOXIDE ON COMPENSATORY TRACKING AND EVENT MONITORING

    EPA Science Inventory

    Experiments by Putz et al. concerning the effect of carbon monoxide (CO) exposure on compensatory tracking and monitoring in healthy young men were replicated. Task and procedural variables were reproduced as closely as practical. Subjects were exposed to either room air or 100 p...

  19. CARBON MONOXIDE FLUXES OF DIFFERENT SOIL LAYERS IN UPLAND CANADIAN BOREAL FORESTS

    EPA Science Inventory

    Dark or low-light carbon monoxide fluxes at upland Canadian boreal forest sites were measured on-site with static chambers and with a laboratory incubation technique using cores from different depths at the same sites. Three different upland black spruce sites, burned in 1987,199...

  20. Ab initio molecular dynamics simulation study of successive hydrogenation reactions of carbon monoxide producing methanol

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pham, Thi Nu; Ono, Shota; Ohno, Kaoru, E-mail: ohno@ynu.ac.jp

    Doing ab initio molecular dynamics simulations, we demonstrate a possibility of hydrogenation of carbon monoxide producing methanol step by step. At first, the hydrogen atom reacts with the carbon monoxide molecule at the excited state forming the formyl radical. Formaldehyde was formed after adding one more hydrogen atom to the system. Finally, absorption of two hydrogen atoms to formaldehyde produces methanol molecule. This study is performed by using the all-electron mixed basis approach based on the time dependent density functional theory within the adiabatic local density approximation for an electronic ground-state configuration and the one-shot GW approximation for an electronicmore » excited state configuration.« less

  1. Influence of carbon monoxide poisoning on the fetal heart monitor tracing: a report of 3 cases.

    PubMed

    Towers, Craig V; Corcoran, Vincent A

    2009-03-01

    The diagnosis of carbon monoxide poisoning in the third trimester of pregnancy requires an index of suspicion, and the appearance of the fetal heart monitor tracing may help in this regard. Three cases of third-trimester acute carbon monoxide poisoning occurred. In each pregnancy, the fetal heart monitor tracing on admission was correlated with the maternal carboxyhemoglobin level, and how the pattern changed following the institution of therapy was analyzed. In all 3 cases, the initial fetal heart rate pattern demonstrated decreased variability with an elevated baseline and an absence of accelerations and decelerations. Within 45-90 minutes of treatment onset, the baseline fetal heart rate dropped by 20-40 beats per minute, the variability became moderate, and accelerations occurred. Absent accelerations with minimal variability, if caused by uteroplacental insufficiency, are usually preceded by recurrent decelerations. Absent accelerations with minimal variability in the absence of recurrent decelerations may suggest another cause, of which carbon monoxide intoxication can be added to the differential, especially since this disorder often has nonspecific clinical symptoms.

  2. Iron catalyst chemistry in modeling a high-pressure carbon monoxide nanotube reactor

    NASA Technical Reports Server (NTRS)

    Scott, Carl D.; Povitsky, Alexander; Dateo, Christopher; Gokcen, Tahir; Willis, Peter A.; Smalley, Richard E.

    2003-01-01

    The high-pressure carbon monoxide (HiPco) technique for producing single-wall carbon nanotubes (SWNTs) is analyzed with the use of a chemical reaction model coupled with flow properties calculated along streamlines, calculated by the FLUENT code for pure carbon monoxide. Cold iron pentacarbonyl, diluted in CO at about 30 atmospheres, is injected into a conical mixing zone, where hot CO is also introduced via three jets at 30 degrees with respect to the axis. Hot CO decomposes the Fe(CO)5 to release atomic Fe. Then iron nucleates and forms clusters that catalyze the formation of SWNTs by a disproportionation reaction (Boudouard) of CO on Fe-containing clusters. Alternative nucleation rates are estimated from the theory of hard sphere collision dynamics with an activation energy barrier. The rate coefficient for carbon nanotube growth is estimated from activation energies in the literature. The calculated growth was found be about an order of magnitude greater than measured, regardless of the nucleation rate. A study of cluster formation in an incubation zone prior to injection into the reactor shows that direct dimer formation from Fe atoms is not as important as formation via an exchange reaction of Fe with CO in FeCO.

  3. Iron catalyst chemistry in modeling a high-pressure carbon monoxide nanotube reactor.

    PubMed

    Scott, Carl D; Povitsky, Alexander; Dateo, Christopher; Gökçen, Tahir; Willis, Peter A; Smalley, Richard E

    2003-01-01

    The high-pressure carbon monoxide (HiPco) technique for producing single-wall carbon nanotubes (SWNTs) is analyzed with the use of a chemical reaction model coupled with flow properties calculated along streamlines, calculated by the FLUENT code for pure carbon monoxide. Cold iron pentacarbonyl, diluted in CO at about 30 atmospheres, is injected into a conical mixing zone, where hot CO is also introduced via three jets at 30 degrees with respect to the axis. Hot CO decomposes the Fe(CO)5 to release atomic Fe. Then iron nucleates and forms clusters that catalyze the formation of SWNTs by a disproportionation reaction (Boudouard) of CO on Fe-containing clusters. Alternative nucleation rates are estimated from the theory of hard sphere collision dynamics with an activation energy barrier. The rate coefficient for carbon nanotube growth is estimated from activation energies in the literature. The calculated growth was found be about an order of magnitude greater than measured, regardless of the nucleation rate. A study of cluster formation in an incubation zone prior to injection into the reactor shows that direct dimer formation from Fe atoms is not as important as formation via an exchange reaction of Fe with CO in FeCO.

  4. Influence of wildfires in the boreal forests of Eastern Siberia on atmospheric aerosol parameters

    NASA Astrophysics Data System (ADS)

    Tomshin, Oleg A.; Solovyev, Vladimir S.

    2017-11-01

    The results of studies of the dynamics of forest fires in the boreal forests of Yakutia (Eastern Siberia) for 2001-2016 are presented. Variations of aerosol optical thickness (AOT), aerosol index (AI) and total carbon monoxide content during May-September were studied depending on the different forest fire activity level. It is shown that the seasonal variations of AOT, AI and CO in the most fire-dangerous years differ significantly from the fire seasons when forest fire activity was medium or low.

  5. Sources and Removal of Springtime Arctic Aerosol

    NASA Astrophysics Data System (ADS)

    Willis, M. D.; Burkart, J.; Bozem, H.; Kunkel, D.; Schulz, H.; Hanna, S.; Aliabadi, A. A.; Bertram, A. K.; Hoor, P. M.; Herber, A. B.; Leaitch, R.; Abbatt, J.

    2017-12-01

    The sources and removal mechanisms of pollution transported to Arctic regions are key factors in controlling the impact of short-lived climate forcing agents on Arctic climate. We lack a predictive understanding of pollution transport to Arctic regions largely due to poor understanding of removal mechanisms and aerosol chemical and physical processing both within the Arctic and during transport. We present vertically resolved observations of aerosol physical and chemical properties in High Arctic springtime. While much previous work has focused on characterizing episodic events of high pollutant concentrations transported to Arctic regions, here we focus on measurements made under conditions consistent with chronic Arctic Haze, which is more representative of the pollution seasonal maximum observed at long term monitoring stations. On six flights based at Alert and Eureka, Nunavut, Canada, we observe evidence for vertical variations in both aerosol sources and removal mechanisms. With support from model calculations, we show evidence for sources of partially neutralized aerosol with higher organic aerosol (OA) and black carbon content in the middle troposphere, compared to lower tropospheric aerosol with higher amounts of acidic sulfate. Further, we show evidence for aerosol depletion relative to carbon monoxide, both in the mid-to-upper troposphere and within the Arctic Boundary Layer (ABL). Dry deposition, with relatively low removal efficiency, was responsible for aerosol removal in the ABL while ice or liquid-phase scavenging was responsible for aerosol removal at higher altitudes during transport. Overall, we find that vertical variations in both regional and remote aerosol sources, and removal mechanisms, combine with long aerosol residence times to drive the properties of springtime Arctic aerosol.

  6. Anion-Receptor Mediated Oxidation of Carbon Monoxide to Carbonate by Peroxide Dianion

    DOE PAGES

    Nava, Matthew; Lopez, Nazario; Muller, Peter; ...

    2015-10-14

    The reactivity of peroxide dianion O 2 2– has been scarcely explored in organic media due to the lack of soluble sources of this reduced oxygen species. We now report the finding that the encapsulated peroxide cryptate, [O 2cmBDCA-5t-H 6] 2– (1), reacts with carbon monoxide in organic solvents at 40 °C to cleanly form an encapsulated carbonate. Characterization of the resulting hexacarboxamide carbonate cryptate by single crystal X-ray diffraction reveals that carbonate dianion forms nine complementary hydrogen bonds with the hexacarboxamide cryptand, [CO 3cmBDCA-5t-H 6] 2– (2), a conclusion that is supported by spectroscopic data. Labeling studies and 17Omore » solid-state NMR data confirm that two-thirds of the oxygen atoms in the encapsulated carbonate derive from peroxide dianion, while the carbon is derived from CO. Further evidence for the formation of a carbonate cryptate was obtained by three methods of independent synthesis: treatment of (i) free cryptand with K 2CO 3; (ii) monodeprotonated cryptand with PPN[HCO 3]; and (iii) free cryptand with TBA[OH] and atmospheric CO 2. This work demonstrates CO oxidation mediated by a hydrogen-bonding anion receptor, constituting an alternative to transition-metal catalysis.« less

  7. Inhalation Toxicology. 11. The Effect of Elevated Temperature on Carbon Monoxide Toxicity

    DTIC Science & Technology

    1990-12-01

    DOT/FAA/AM-90/16 Inhalation Toxicology : XI. The Effect of Elevated Temperature on Carbon Office of Aviation Medicine Washington, D.C. 20591 M onoxide...Accession No. 3. Recipient’s Catalog No. DOT/FAA/AM-90/16 4. Title and Subtitie S. Report Date INHALATION TOXICOLOGY : XI. THE EFFECT OF ELEVATED December...Statement Combustion toxicology , carbon monoxide, This document is available to the public heat, thermal effects, time-to- through the National Technical

  8. TES/MLS Aura L2 Carbon Monoxide (CO) Nadir (TML2CO)

    Atmospheric Science Data Center

    2018-05-06

    TES/MLS Aura L2 Carbon Monoxide (CO) Nadir (TML2CO) Atmospheric ... profile estimates and associated errors derived using TES & MLS spectral radiance measurements taken at nearest time and locations. ... a priori constraint vectors. News:  TES News Join TES News List Project Title:  TES ...

  9. TES/MLS Aura L2 Carbon Monoxide (CO) Nadir (TML2CO)

    Atmospheric Science Data Center

    2018-05-07

    TES/MLS Aura L2 Carbon Monoxide (CO) Nadir (TML2CO) ... profile estimates and associated errors derived using TES & MLS spectral radiance measurements taken at nearest time and locations. ... a priori constraint vectors. News:  TES News Join TES News List Project Title:  TES ...

  10. Hemispheric aerosol vertical profiles: anthropogenic impacts on optical depth and cloud nuclei.

    PubMed

    Clarke, Antony; Kapustin, Vladimir

    2010-09-17

    Understanding the effect of anthropogenic combustion upon aerosol optical depth (AOD), clouds, and their radiative forcing requires regionally representative aerosol profiles. In this work, we examine more than 1000 vertical profiles from 11 major airborne campaigns in the Pacific hemisphere and confirm that regional enhancements in aerosol light scattering, mass, and number are associated with carbon monoxide from combustion and can exceed values in unperturbed regions by more than one order of magnitude. Related regional increases in a proxy for cloud condensation nuclei (CCN) and AOD imply that direct and indirect aerosol radiative effects are coupled issues linked globally to aged combustion. These profiles constrain the influence of combustion on regional AOD and CCN suitable for challenging climate model performance and informing satellite retrievals.

  11. Combustion characteristics of hydrogen. Carbon monoxide based gaseous fuels

    NASA Technical Reports Server (NTRS)

    Notardonato, J. J.; White, D. J.; Kubasco, A. J.; Lecren, R. T.

    1981-01-01

    An experimental rig program was conducted with the objective of evaluating the combuston performance of a family of fuel gases based on a mixture of hydrogen and carbon monoxide. These gases, in addition to being members of a family, were also representative of those secondary fuels that could be produced from coal by various gasification schemes. In particular, simulated Winkler, Lurgi, and Blue-water low and medium energy content gases were used as fuels in the experimental combustor rig. The combustor used was originally designed as a low NOx rich-lean system for burning liquid fuels with high bound nitrogen levels. When used with the above gaseous fuels this combustor was operated in a lean-lean mode with ultra long residence times. The Blue-water gas was also operated in a rich-lean mode. The results of these tests indicate the possibility of the existence of an 'optimum' gas turbine hydrogen - carbon monoxide based secondary fuel. Such a fuel would exhibit NOx and high efficiency over the entire engine operating range. It would also have sufficient stability range to allow normal light-off and engine acceleration. Solar Turbines Incorporated would like to emphasize that the results presented here have been obtained with experimental rig combustors. The technologies generated could, however, be utilized in future commercial gas turbines.

  12. Measurements of Carbon Dioxide, Carbon Monoxide, and Other Related Tracers at High Spatial and Temporal Resolution in an Urban Environment

    NASA Astrophysics Data System (ADS)

    Rella, C.; Jacobson, G.

    2012-04-01

    The ability to quantify the sources and sinks of carbon dioxide on the urban scale is essential for understanding the atmospheric drivers to global climate change. In the 'top-down' approach, overall carbon fluxes are determined by combining remote measurements of carbon dioxide concentrations with complex atmospheric transport models, and these emissions measurements are compared to "bottoms-up" predictions based on detailed inventories of the sources and sinks of carbon, both anthropogenic and biogenic in nature. This approach, which has been proven to be effective at continental scales, becomes challenging to implement at the urban scale, due to poorly understood micrometeorological atmospheric transport models and high variability of the emissions sources in space (e.g., factories, highways, residences) and time (rush hours, factory shifts and shutdowns, residential energy usage variability during the day and over the year). New measurement and analysis techniques are required to make sense of the carbon dioxide signal in cities. Here we present detailed, high spatial- and temporal-resolution greenhouse gas measurements in Silicon Valley in California. The synthesis of two experimental campaigns is presented: real-time measurements from two ten-meter urban 'towers,' and ground-based mobile mapping measurements. Real-time carbon dioxide data from a nine-month period are combined with real-time carbon monoxide, methane, acetylene, and carbon 13 measurements to partition the observed CO2 concentrations between different anthropogenic sectors (e.g., transport, residential) and biogenic sources. The carbon monoxide to carbon dioxide ratio is shown to vary over more than a factor of two from season to season or even from day to night, indicating rapid and frequent shifts in the balance between different carbon dioxide sources. Clear differences are seen between the two urban sites, which are separated by 7 km. Further information is given by the carbon 13 signature

  13. Carbon monoxide and related trace gases and aerosols over the Amazon Basin during the wet and dry seasons

    NASA Astrophysics Data System (ADS)

    Andreae, M. O.; Artaxo, P.; Beck, V.; Bela, M.; Freitas, S.; Gerbig, C.; Longo, K.; Munger, J. W.; Wiedemann, K. T.; Wofsy, S. C.

    2012-03-01

    We present the results of airborne measurements of carbon monoxide (CO) and aerosol particle number concentration (CN) made during the Balanço Atmosférico Regional de Carbono na Amazônia (BARCA) program. The primary goal of BARCA is to address the question of basin-scale sources and sinks of CO2 and other atmospheric carbon species, a central issue of the Large-scale Biosphere-Atmosphere (LBA) program. The experiment consisted of two aircraft campaigns during November-December 2008 (BARCA-A) and May 2009 (BARCA-B), which covered the altitude range from the surface up to about 4500 m, and spanned most of the Amazon Basin. Based on meteorological analysis and measurements of the tracer, SF6, we found that airmasses over the Amazon Basin during the late dry season (BARCA-A, November 2008) originated predominantly from the Southern Hemisphere, while during the late wet season (BARCA-B, May 2009) low-level airmasses were dominated by northern-hemispheric inflow, and mid-tropospheric airmasses were of mixed origin. In BARCA-A we found strong influence of biomass burning emissions on the composition of the atmosphere over much of the Amazon Basin, with CO enhancements up to 300 ppb and CN concentrations approaching 10 000 cm-3; the highest values were in the southern part of the Basin at altitudes of 1-3 km. The ΔCN/ΔCO ratios were diagnostic for biomass burning emissions, and were lower in aged than in fresh smoke. Fresh emissions indicated CO/CO2 and CN/CO emission ratios in good agreement with previous work, but our results also highlight the need to consider the residual smoldering combustion that takes place after the active flaming phase of deforestation fires. During the late wet season, in contrast, there was little evidence for a significant presence of biomass smoke. Low CN concentrations (300-500 cm-3) prevailed basinwide, and CO mixing ratios were enhanced by only ~10 ppb above the mixing line between Northern and Southern Hemisphere air. There was no

  14. Carbon monoxide and related trace gases and aerosols over the Amazon Basin during the wet and dry seasons

    NASA Astrophysics Data System (ADS)

    Andreae, M. O.; Artaxo, P.; Beck, V.; Bela, M.; Freitas, S.; Gerbig, C.; Longo, K.; Munger, J. W.; Wiedemann, K. T.; Wofsy, S. C.

    2012-07-01

    We present the results of airborne measurements of carbon monoxide (CO) and aerosol particle number concentration (CN) made during the Balanço Atmosférico Regional de Carbono na Amazônia (BARCA) program. The primary goal of BARCA is to address the question of basin-scale sources and sinks of CO2 and other atmospheric carbon species, a central issue of the Large-scale Biosphere-Atmosphere (LBA) program. The experiment consisted of two aircraft campaigns during November-December 2008 (BARCA-A) and May-June 2009 (BARCA-B), which covered the altitude range from the surface up to about 4500 m, and spanned most of the Amazon Basin. Based on meteorological analysis and measurements of the tracer, SF6, we found that airmasses over the Amazon Basin during the late dry season (BARCA-A, November 2008) originated predominantly from the Southern Hemisphere, while during the late wet season (BARCA-B, May 2009) low-level airmasses were dominated by northern-hemispheric inflow and mid-tropospheric airmasses were of mixed origin. In BARCA-A we found strong influence of biomass burning emissions on the composition of the atmosphere over much of the Amazon Basin, with CO enhancements up to 300 ppb and CN concentrations approaching 10 000 cm-3; the highest values were in the southern part of the Basin at altitudes of 1-3 km. The ΔCN/ΔCO ratios were diagnostic for biomass burning emissions, and were lower in aged than in fresh smoke. Fresh emissions indicated CO/CO2 and CN/CO emission ratios in good agreement with previous work, but our results also highlight the need to consider the residual smoldering combustion that takes place after the active flaming phase of deforestation fires. During the late wet season, in contrast, there was little evidence for a significant presence of biomass smoke. Low CN concentrations (300-500 cm-3) prevailed basinwide, and CO mixing ratios were enhanced by only ~10 ppb above the mixing line between Northern and Southern Hemisphere air. There was no

  15. Catalysts for the Oxidation of Carbon Monoxide at Low Temperatures.

    DTIC Science & Technology

    1979-11-21

    Four catalysts ( hopcalite , Whetlerite, a supported palladium, and a supported platinum) were tested for efficiency in promoting the oxidation of...carbon monoxide (CO). At room temperature and 50% RH, hopcalite has no catalytic capability and platinum has practically none. At room temperature and 15...RH, hopcalite is superior to platinum in catalyzing the oxidation of CO. Hopcalite is more efficient than either of the other three catalysts in the

  16. Yields of tar, nicotine, and carbon monoxide in the sidestream smoke from 15 brands of Canadian cigarettes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rickert, W.S.; Robinson, J.C.; Collishaw, N.

    Sidestream smoke yields for 15 brands of cigarettes were determined under conditions where mainstream yields were approximately equal to those used for determining the values which appear on packages of Canadian cigarettes. Sidestream yields of tar, nicotine, and carbon monoxide were much higher than mainstream yields for all brands tested. The average sidestream-to-mainstream ratios for the 15 brands were 3.5, 6.6, and 6.8 for tar, nicotine, and carbon monoxide, respectively. The highest yields of sidestream were obtained from the brands with the lowest mainstream yields.

  17. The effect of ambient temperature and humidity on the carbon monoxide emissions of an idling gas turbine

    NASA Technical Reports Server (NTRS)

    Kauffman, C. W.; Subramaniam, A. K.

    1977-01-01

    Changes in ambient temperature and humidity affect the exhaust emissions of a gas turbine engine. The results of a test program employing a JT8D combustor are presented which quantize the effect of these changes on carbon monoxide emissions at simulated idle operating conditions. Analytical results generated by a kinetic model of the combustion process and reflecting changing ambient conditions are given. It is shown that for a complete range of possible ambient variations, significant changes do occur in the amount of carbon monoxide emitted by a gas turbine engine.

  18. Sublimation rates of carbon monoxide and carbon dioxide from comets at large heliocentric distances

    NASA Technical Reports Server (NTRS)

    Sekanina, Zdenek

    1992-01-01

    Using a simple model for outgassing from a small flat surface area, the sublimation rates of carbon monoxide and carbon dioxide, two species more volatile than water ice that are known to be present in comets, are calculated for a suddenly activated discrete source on the rotating nucleus. The instantaneous sublimation rate depends upon the comet's heliocentric distance and the Sun's zenith angle at the location of the source. The values are derived for the constants of CO and CO2 in an expression that yields the local rotation-averaged sublimation rate as a function of the comet's spin parameters and the source's cometocentric latitude.

  19. An empirical relationship between mesoscale carbon monoxide concentrations and vehicular emission rates : final report.

    DOT National Transportation Integrated Search

    1979-01-01

    Presented is a relatively simple empirical equation that reasonably approximates the relationship between mesoscale carbon monoxide (CO) concentrations, areal vehicular CO emission rates, and the meteorological factors of wind speed and mixing height...

  20. New Class of Hybrid Materials for Detection, Capture, and "On-Demand" Release of Carbon Monoxide.

    PubMed

    Pitto-Barry, Anaïs; Lupan, Alexandru; Ellingford, Christopher; Attia, Amr A A; Barry, Nicolas P E

    2018-04-25

    Carbon monoxide (CO) is both a substance hazardous to health and a side product of a number of industrial processes, such as methanol steam reforming and large-scale oxidation reactions. The separation of CO from nitrogen (N 2 ) in industrial processes is considered to be difficult because of the similarities of their electronic structures, sizes, and physicochemical properties (e.g., boiling points). Carbon monoxide is also a major poison in fuel cells because of its adsorption onto the active sites of the catalysts. It is therefore of the utmost economic importance to discover new materials that enable effective CO capture and release under mild conditions. However, methods to specifically absorb and easily release CO in the presence of contaminants, such as water, nitrogen, carbon dioxide, and oxygen, at ambient temperature are not available. Here, we report the simple and versatile fabrication of a new class of hybrid materials that allows capture and release of carbon monoxide under mild conditions. We found that carborane-containing metal complexes encapsulated in networks made of poly(dimethylsiloxane) react with CO, even when immersed in water, leading to dramatic color and infrared signature changes. Furthermore, we found that the CO can be easily released from the materials by simply dipping the networks into an organic solvent for less than 1 min, at ambient temperature and pressure, which not only offers a straightforward recycling method, but also a new method for the "on-demand" release of carbon monoxide. We illustrated the utilization of the on-demand release of CO from the networks by carrying out a carbonylation reaction on an electron-deficient metal complex that led to the formation of the CO-adduct, with concomitant recycling of the gel. We anticipate that our sponge-like materials and scalable methodology will open up new avenues for the storage, transport, and controlled release of CO, the silent killer and a major industrial poison.

  1. Strong radiative heating due to the mixing state of black carbon in atmospheric aerosols.

    PubMed

    Jacobson, M Z

    2001-02-08

    Aerosols affect the Earth's temperature and climate by altering the radiative properties of the atmosphere. A large positive component of this radiative forcing from aerosols is due to black carbon--soot--that is released from the burning of fossil fuel and biomass, and, to a lesser extent, natural fires, but the exact forcing is affected by how black carbon is mixed with other aerosol constituents. From studies of aerosol radiative forcing, it is known that black carbon can exist in one of several possible mixing states; distinct from other aerosol particles (externally mixed) or incorporated within them (internally mixed), or a black-carbon core could be surrounded by a well mixed shell. But so far it has been assumed that aerosols exist predominantly as an external mixture. Here I simulate the evolution of the chemical composition of aerosols, finding that the mixing state and direct forcing of the black-carbon component approach those of an internal mixture, largely due to coagulation and growth of aerosol particles. This finding implies a higher positive forcing from black carbon than previously thought, suggesting that the warming effect from black carbon may nearly balance the net cooling effect of other anthropogenic aerosol constituents. The magnitude of the direct radiative forcing from black carbon itself exceeds that due to CH4, suggesting that black carbon may be the second most important component of global warming after CO2 in terms of direct forcing.

  2. Carbon Monoxide in Mid-Troposphere over Indonesia Fires, October 2015

    NASA Image and Video Library

    2015-10-30

    Widespread forest fires across Indonesia have burned tens of thousands of acres over three months, causing high levels of pollution, loss of life, and billions of dollars to the Indonesian government. It is estimated that more than 43 million people have been inhaling toxic fumes, and large parts of Indonesia have been placed in a state of emergency. Most of the fires are believed to have been set to clear farmland during the dry season, but a long term drought enhanced by El Niño conditions have contributed to the fires remaining unchecked due to lack of rain. These images made with data acquired by AIRS, the Atmospheric Infrared Sounder on NASA's Aqua Satellite, show the global concentration of carbon monoxide at the 500hPa pressure level, or approximately 18,000 feet (5,500 meters) altitude. The data are an average of measurements taken over three days, from October 14 through 16, and October 26 through 28, and the high concentration and large extent of the fires over Indonesia are quite apparent. While the scale for this image extends to 400 parts per billion, local values of carbon monoxide can be significantly higher. http://photojournal.jpl.nasa.gov/catalog/PIA20042

  3. Integrated Science Assessment (ISA) for Carbon Monoxide (Second External Review Draft, Sep 2009)

    EPA Science Inventory

    EPA announced that the Second External Review Draft of the Integrated Science Assessment (ISA) for Carbon Monoxide (CO) and related Annexes was made available for independent peer review and public review. This draft ISA document represents a concise synthesis and evaluation of t...

  4. Integrated Science Assessment (ISA) for Carbon Monoxide (First External Review Draft, Mar 2009)

    EPA Science Inventory

    EPA announced that the First External Review Draft of the Integrated Science Assessment (ISA) for Carbon Monoxide (CO) and related Annexes was made available for independent peer review and public review. This draft ISA document represents a concise synthesis and evaluation of th...

  5. 49 CFR 392.66 - Carbon monoxide; use of commercial motor vehicle when detected.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... (Continued) FEDERAL MOTOR CARRIER SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION FEDERAL MOTOR CARRIER SAFETY REGULATIONS DRIVING OF COMMERCIAL MOTOR VEHICLES Prohibited Practices § 392.66 Carbon monoxide; use of commercial motor vehicle when detected. (a) No person shall dispatch or drive any commercial...

  6. Optimization of bio-ethanol autothermal reforming and carbon monoxide removal processes

    NASA Astrophysics Data System (ADS)

    Markova, D.; Bazbauers, G.; Valters, K.; Alhucema Arias, R.; Weuffen, C.; Rochlitz, L.

    Experimental investigation of bio-ethanol autothermal reforming (ATR) and water-gas shift (WGS) processes for hydrogen production and regression analysis of the data is performed in the study. The main goal was to obtain regression relations between the most critical dependent variables such as hydrogen, carbon monoxide and methane content in the reformate gas and independent factors such as air-to-fuel ratio (λ), steam-to-carbon ratio (S/C), inlet temperature of reactants into reforming process (T ATRin), pressure (p) and temperature (T ATR) in the ATR reactor from the experimental data. Purpose of the regression models is to provide optimum values of the process factors that give the maximum amount of hydrogen. The experimental ATR system consisted of an evaporator, an ATR reactor and a one-stage WGS reactor. Empirical relations between hydrogen, carbon monoxide, methane content and the controlling parameters downstream of the ATR reactor are shown in the work. The optimization results show that within the considered range of the process factors the maximum hydrogen concentration of 42 dry vol. % and yield of 3.8 mol mol -1 of ethanol downstream of the ATR reactor can be achieved at S/C = 2.5, λ = 0.20-0.23, p = 0.4 bar, T ATRin = 230 °C, T ATR = 640 °C.

  7. 40 CFR 52.243 - Interim approval of the Carbon Monoxide plan for the South Coast.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 3 2010-07-01 2010-07-01 false Interim approval of the Carbon Monoxide plan for the South Coast. 52.243 Section 52.243 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS California § 52.243 Interim approval of the Carbon...

  8. 40 CFR 52.243 - Interim approval of the Carbon Monoxide plan for the South Coast.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 3 2014-07-01 2014-07-01 false Interim approval of the Carbon Monoxide plan for the South Coast. 52.243 Section 52.243 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS California § 52.243 Interim approval of the Carbon...

  9. 40 CFR 52.243 - Interim approval of the Carbon Monoxide plan for the South Coast.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 3 2013-07-01 2013-07-01 false Interim approval of the Carbon Monoxide plan for the South Coast. 52.243 Section 52.243 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS California § 52.243 Interim approval of the Carbon...

  10. 40 CFR 52.243 - Interim approval of the Carbon Monoxide plan for the South Coast.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 3 2012-07-01 2012-07-01 false Interim approval of the Carbon Monoxide plan for the South Coast. 52.243 Section 52.243 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS California § 52.243 Interim approval of the Carbon...

  11. Chemical Properties of Brown Carbon Aerosol Generated at the Missoula Fire Sciences Laboratory

    NASA Astrophysics Data System (ADS)

    Washenfelder, R. A.; Womack, C.; Franchin, A.; Middlebrook, A. M.; Wagner, N.; Manfred, K.

    2017-12-01

    Aerosol scattering and absorption are still among the largest uncertainties in quantifying radiative forcing. Biomass burning is a major source of light-absorbing carbonaceous aerosol in the United States. These aerosol are generally classified into two categories: black carbon (graphitic-like aerosol that absorbs broadly across the ultraviolet and visible spectral regions) and brown carbon (organic aerosol that absorbs strongly in the ultraviolet and near-visible spectral regions). The composition, volatility, and chemical aging of brown carbon are poorly known, but are important to understanding its radiative effects. We deployed three novel instruments to the Missoula Fire Sciences Laboratory in 2016 to measure brown carbon absorption: a photoacoustic spectrometer, broadband cavity enhanced spectrometer, and particle-into-liquid sampler coupled to a liquid waveguide capillary cell. The instruments sampled from a shared inlet with well-characterized dilution and thermal denuding. We sampled smoke from 32 controlled burns of fuels relevant to western U.S. wildfires. We use these measurements to determine the volatility of water-soluble brown carbon, and compare this to the volatility of water-soluble organic aerosol and total organic aerosol. We further examine the wavelength-dependence of the water-soluble brown carbon absorption as a function of denuder temperature. Together this gives new information about the solubility, volatility, and chemical composition of brown carbon.

  12. Carbon Isotopic Measurements and Aerosol Optical Determinations during CARES: Indications of the Importance of Background Biogenic Aerosols

    NASA Astrophysics Data System (ADS)

    Gaffney, J. S.; Marley, N. A.; Begum, M.; Sturchio, N. C.; Guilderson, T. P.

    2011-12-01

    High volume size-fractionated aerosol samples were obtained in Cool, CA during the Carbonaceous Aerosol and Radiative Effects Study (CARES) in June of 2010. This site was chosen to study the regional impacts of carbonaceous aerosols originating from the Sacramento area. Samples were collected for 6 to 24 hour time periods on quartz fiber filters by using slotted impactors to allow for collection of sample size cuts above and below one micron. Both total carbon content and carbon isotopic composition, including 13C/12C and 14C, were determined on the samples. In addition, Ångstrom absorption exponents (AAEs) were determined for the region of 300-900 nm on the sub-micron size cut by using state of the art diffuse reflectance UV-visible spectroscopy with integrating sphere technology. The overall carbonaceous aerosol loadings were found to be quite low and relatively constant during the study, suggesting that most of the aerosols at the site were locally formed background aerosols. The 14C data is consistent with a substantial fraction (~80 %) being from modern carbon sources and 13C/12C results indicate that the carbon source was from C-3 plants. This is consistent with a significant fraction of the aerosols in the area arising from secondary formation from biogenic precursor emissions from trees, most likely mono- and sesquiterpenes. These results are compared to past results obtained in Mexico City and discussed in terms of the potential importance of biogenic emissions to UV absorbing aerosols as these are anticipated to increase with climate change. This work was supported by the Office of Science (BER), U.S. Department of Energy, Grant No. DE-FG02-07ER64328 and Grant No. DE-FG02-07-ER64329 as part of the Atmospheric Systems Research program.

  13. Molten metal reactor and method of forming hydrogen, carbon monoxide and carbon dioxide using the molten alkaline metal reactor

    DOEpatents

    Bingham, Dennis N.; Klingler, Kerry M.; Turner, Terry D.; Wilding, Bruce M.

    2012-11-13

    A molten metal reactor for converting a carbon material and steam into a gas comprising hydrogen, carbon monoxide, and carbon dioxide is disclosed. The reactor includes an interior crucible having a portion contained within an exterior crucible. The interior crucible includes an inlet and an outlet; the outlet leads to the exterior crucible and may comprise a diffuser. The exterior crucible may contain a molten alkaline metal compound. Contained between the exterior crucible and the interior crucible is at least one baffle.

  14. Observation of hydration of single, modified carbon aerosols

    NASA Technical Reports Server (NTRS)

    Wyslouzil, B. E.; Carleton, K. L.; Sonnenfroh, D. M.; Rawlins, W. T.; Arnold, S.

    1994-01-01

    We have compared the hydration behavior of single carbon particles that have been treated by exposure to gaseous H2SO4 with that of untreated particles. Untreated carbon particles did not hydrate as the relative humidity varied from 0 to 80% at 23 C. In contrast, treated particles hydrated under subsaturation conditions; mass increases of up to 30% were observed. The mass increase is consistent with sulfuric acid equilibration with the ambient relative humidity in the presence of inert carbon. For the samples studied, the average amount of absorbed acid was 14% +/- 6% by weight, which corresponds to a surface coverage of approximately 0.1 monolayer. The mass fraction of surface-absorbed acid is comparable to the soluble mass fraction observed by Whitefield et al. (1993) in jet aircraft engine aerosols. Estimates indicate this mass fraction corresponds to 0.1% of the available SO2 exiting an aircraft engine ending up as H2SO4 on the carbon aerosol. If this heterogeneous process occurs early enough in the exhaust plume, it may compete with homogeneous nucleation as a mechanism for producing sulfuric acid rich aerosols.

  15. Reduction of Carbon Monoxide. Past Research Summary

    DOE R&D Accomplishments Database

    Schrock, R. R.

    1982-01-01

    Research programs for the year on the preparation, characterization, and reactions of binuclear tantalum complexes are described. All evidence to date suggest the following of these dimeric molecules: (1) the dimer does not break into monomers under mild conditions; (2) intermolecular hydride exchange is not negligible, but it is slow; (3) intermolecular non-ionic halide exchange is fast; (4) the ends of the dimers can rotate partially with respect to one another. The binuclear tantalum hydride complexes were found to react with carbon monoxide to give a molecule which is the only example of reduction of CO by a transition metal hydride to give a complex containing a CHO ligand. Isonitrides also reacted in a similar manner with dimeric tantalum hydride. (ATT)

  16. 76 FR 53364 - Recreational Vessel Propeller Strike and Carbon Monoxide Poisoning Casualty Prevention

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-26

    ... in Outdoor Recreation Activity Participation--1980 to Now, May 2009 (A Recreation Research Report in the Internet Research Information Series), available at http://warnell.forestry.uga.edu/nrrt/nsre... casualties caused by propeller strikes and carbon monoxide (CO) poisoning, we will hold a meeting at a time...

  17. Pathology of deaths from carbon monoxide poisoning in Port Harcourt: an autopsy study of 75 cases.

    PubMed

    Seleye-Fubara, D; Etebu, E N; Athanasius, B

    2011-01-01

    Carbon monoxide (CO) poisoning is a notable cause of death at homes and industries that is posing public health problem worldwide that requires an elaborate study. To study and characterize deaths resulting from the noxious gas (CO). A ten year (January 1st, 1995 December 31st 2004) autopsy study. Port Harcourt, Nigeria. Coroners and hospital autopsies performed by the authors at the University of Port Harcourt Teaching Hospital (UPTH), other hospitals and private mortuaries in Port Harcourt on deaths from carbon monoxide poisoning were studied over ten years. The circumstances of death reported by police were accidental, homicidal or suicidal; and other autopsy findings were used for the study. A total of seventy five autopsies were studied; out which 21 (28.0%) were females and 54 (72.0%) males giving a ratio 1:2.6 male dominance. The highest frequency of death 25 (33.3%) occurred in the age group 60 69 years; while the least 3 (4%) occurred in the age group 0 9 years. The youngest was an unborn 7 month old male fetus while the eldest was 85 years old female. The most common was accidental carbon monoxide poisoning which accounted for 48 (64%) cases. While Homicidal CO poisoning .was 24 (32%) and suicidal CO poisoning was 3 (4.0%). Body recovered from fumy electric generator rooms was 46 (61.3%) while least frequency was bodies recovered from naked flame 3 (4%). Carbon monoxide poisoning is posing a serious public health problem when ever it occurs. There is need for public enlightenment about this gas as it is related to fumes from generator, car exhausts, poorly ventilated rooms and enclosed chambers in order to reduce the carnage associated with it both at home and industries.

  18. Pathways and Bioenergetics of Anaerobic Carbon Monoxide Fermentation.

    PubMed

    Diender, Martijn; Stams, Alfons J M; Sousa, Diana Z

    2015-01-01

    Carbon monoxide can act as a substrate for different modes of fermentative anaerobic metabolism. The trait of utilizing CO is spread among a diverse group of microorganisms, including members of bacteria as well as archaea. Over the last decade this metabolism has gained interest due to the potential of converting CO-rich gas, such as synthesis gas, into bio-based products. Three main types of fermentative CO metabolism can be distinguished: hydrogenogenesis, methanogenesis, and acetogenesis, generating hydrogen, methane and acetate, respectively. Here, we review the current knowledge on these three variants of microbial CO metabolism with an emphasis on the potential enzymatic routes and bio-energetics involved.

  19. Pathways and Bioenergetics of Anaerobic Carbon Monoxide Fermentation

    PubMed Central

    Diender, Martijn; Stams, Alfons J. M.; Sousa, Diana Z.

    2015-01-01

    Carbon monoxide can act as a substrate for different modes of fermentative anaerobic metabolism. The trait of utilizing CO is spread among a diverse group of microorganisms, including members of bacteria as well as archaea. Over the last decade this metabolism has gained interest due to the potential of converting CO-rich gas, such as synthesis gas, into bio-based products. Three main types of fermentative CO metabolism can be distinguished: hydrogenogenesis, methanogenesis, and acetogenesis, generating hydrogen, methane and acetate, respectively. Here, we review the current knowledge on these three variants of microbial CO metabolism with an emphasis on the potential enzymatic routes and bio-energetics involved. PMID:26635746

  20. Conversion of carbon dioxide to carbon monoxide by pulse dielectric barrier discharge plasma

    NASA Astrophysics Data System (ADS)

    Wang, Taobo; Liu, Hongxia; Xiong, Xiang; Feng, Xinxin

    2017-01-01

    The conversion of carbon dioxide (CO2) to carbon monoxide (CO) was investigated in a non-thermal plasma dielectric barrier discharge (DBD) reactor, and the effects of different process conditions on the CO2 conversion were investigated. The results showed that the increase of input power could optimize the conversion of CO2 to CO. The CO2 conversion and CO yield were negatively correlated with the gas flow rate, but there was an optimum gas flow rate, that made the CO selectivity best. The carrier gas (N2, Ar) was conducive to the conversion of CO2, and the effect of N2 as carrier gas was better than Ar. The conversion of CO2 to CO was enhanced by addition of the catalyst (5A molecular sieve).

  1. Analysis of GASP carbon monoxide data

    NASA Technical Reports Server (NTRS)

    Wu, M. F.

    1981-01-01

    Atmospheric carbon monoxide in the upper troposphere and lower stratosphere for the period March 1977 through October 1978 was analyzed. The CO data are summarized and the distribution and variations in space and time of this gas are presented. The data show that the CO mixing ratios are higher in the troposphere than those in the stratosphere. In the Northern Hemisphere the highest value of CO mixing ratio occurs in spring, although more data are needed to verify these findings. Correlation coefficients among CO, O3, air temperature (T) and winds were calculated for different regions under different seasons. It was found that the CO correlates negatively with O3 above 20 degrees latitude and positively below that latitude. Case studies using the data of CO, O3, and T measured simultaneously were performed. Discussions and suggestions are made. Ozone data on seasonal basis is also summarized.

  2. Triton's Summer Sky of Methane and Carbon Monoxide

    NASA Astrophysics Data System (ADS)

    2010-04-01

    According to the first ever infrared analysis of the atmosphere of Neptune's moon Triton, summer is in full swing in its southern hemisphere. The European observing team used ESO's Very Large Telescope and discovered carbon monoxide and made the first ground-based detection of methane in Triton's thin atmosphere. These observations revealed that the thin atmosphere varies seasonally, thickening when warmed. "We have found real evidence that the Sun still makes its presence felt on Triton, even from so far away. This icy moon actually has seasons just as we do on Earth, but they change far more slowly," says Emmanuel Lellouch, the lead author of the paper reporting these results in Astronomy & Astrophysics. On Triton, where the average surface temperature is about minus 235 degrees Celsius, it is currently summer in the southern hemisphere and winter in the northern. As Triton's southern hemisphere warms up, a thin layer of frozen nitrogen, methane, and carbon monoxide on Triton's surface sublimates into gas, thickening the icy atmosphere as the season progresses during Neptune's 165-year orbit around the Sun. A season on Triton lasts a little over 40 years, and Triton passed the southern summer solstice in 2000. Based on the amount of gas measured, Lellouch and his colleagues estimate that Triton's atmospheric pressure may have risen by a factor of four compared to the measurements made by Voyager 2 in 1989, when it was still spring on the giant moon. The atmospheric pressure on Triton is now between 40 and 65 microbars - 20 000 times less than on Earth. Carbon monoxide was known to be present as ice on the surface, but Lellouch and his team discovered that Triton's upper surface layer is enriched with carbon monoxide ice by about a factor of ten compared to the deeper layers, and that it is this upper "film" that feeds the atmosphere. While the majority of Triton's atmosphere is nitrogen (much like on Earth), the methane in the atmosphere, first detected by

  3. 40 CFR 52.269 - Control strategy and regulations: Photochemical oxidants (hydrocarbons) and carbon monoxide.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ...: Photochemical oxidants (hydrocarbons) and carbon monoxide. 52.269 Section 52.269 Protection of Environment... PLANS California § 52.269 Control strategy and regulations: Photochemical oxidants (hydrocarbons) and... provide for attainment and maintenance of the national standards for photochemical oxidants (hydrocarbons...

  4. 40 CFR 52.269 - Control strategy and regulations: Photochemical oxidants (hydrocarbons) and carbon monoxide.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...: Photochemical oxidants (hydrocarbons) and carbon monoxide. 52.269 Section 52.269 Protection of Environment... PLANS California § 52.269 Control strategy and regulations: Photochemical oxidants (hydrocarbons) and... provide for attainment and maintenance of the national standards for photochemical oxidants (hydrocarbons...

  5. 49 CFR 392.66 - Carbon monoxide; use of commercial motor vehicle when detected.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 5 2012-10-01 2012-10-01 false Carbon monoxide; use of commercial motor vehicle when detected. 392.66 Section 392.66 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL MOTOR CARRIER SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION FEDERAL MOTOR CARRIER SAFETY REGULATIONS DRIVING OF COMMERCIAL MOTO...

  6. 49 CFR 392.66 - Carbon monoxide; use of commercial motor vehicle when detected.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 5 2013-10-01 2013-10-01 false Carbon monoxide; use of commercial motor vehicle when detected. 392.66 Section 392.66 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL MOTOR CARRIER SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION FEDERAL MOTOR CARRIER SAFETY REGULATIONS DRIVING OF COMMERCIAL MOTO...

  7. 49 CFR 392.66 - Carbon monoxide; use of commercial motor vehicle when detected.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 5 2014-10-01 2014-10-01 false Carbon monoxide; use of commercial motor vehicle when detected. 392.66 Section 392.66 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL MOTOR CARRIER SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION FEDERAL MOTOR CARRIER SAFETY REGULATIONS DRIVING OF COMMERCIAL MOTO...

  8. The Importance of H-FABP in Determining the Severity of Carbon Monoxide Poisoning.

    PubMed

    Koylu, Ramazan; Cander, Basar; Dundar, Zerrin Defne; Koylu, Oznur; Akilli, Nazire Belgin; Ivelik, Korhan

    2011-12-01

    In this study, we aimed to investigate the importance of the use of heart-type fatty acid binding protein (H-FABP) in evaluating the myocardial damage in patients admitted to the emergency department with moderate to severe carbon monoxide (CO) poisoning. All patients admitted to the emergency department with severe acute CO intoxication were enrolled the study. The H-FABP and cardiac biomarker levels were assessed at 0, 6th and 24th hours. The patients were divided into groups as those with normal echocardiography findings and with wall motion abnormalities. The differences between the groups for these parameters were compared. The mean age of 80 patients was 32.3 ± 12.9 years old. 42 of them were male. On admission, 29 (36.3%) had elevated serum troponin I levels and 56 (70.0%) had elevated serum H-FABP levels. At 6thhour, 4 (5.0%) of 80 patients had higher serum H-FABP levels and 23 (28.8%) of them had higher serum Troponin I levels than 0 hour. The patients with wall motion abnormality had significantly higher serum H-FABP levels compared to the patients with normal echocardiography findings at 6th and 24th hours (p = 0.001 and 0.009). While the serum COHb and H-FABP levels tended to decrease continuously in time (p < 0.001), the serum troponin I levels increased at 6th hour and then decreased at 24th hour (p = 0.017). The serum H-FABP levels are useful in identifying the myocardial damage in patients admitted to the emergency department with moderate to severe carbon monoxide poisoning at an early phase. Carbon monoxide; Poisoning; H-FABP; Myocardial injury.

  9. An overview of carbon monoxide generation and release by home appliances

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Batey, J

    Carbon monoxide (CO) is an odorless, colorless and tasteless gas which is highly toxic and can be produced by many combustion sources commonly found within homes. Potential sources include boilers and furnaces, water heaters, space heaters, stoves, ovens, clothes dryers, wood stoves, fireplaces, charcoal grilles, automobiles, cigarettes, oil lamps, and candles. Any fuel that contains carbon can form CO including, natural gas, propane, kerosene, fuel oil, wood, and coal. Exposure to elevated CO levels typically requires its production by a combustion source and its release into the home through a venting system malfunction. The health effects of CO range frommore » headaches and flue-like symptoms to loss of concentration, coma and death depending on the concentration of CO and the exposure time. At levels of only 1%, which is the order of magnitude produced by automobile exhaust, carbon monoxide can cause death in less than 3 minutes. While most combustion equipment operate with low CO levels, many operating factors can contribute to elevated CO levels in the home including: burner adjustment, combustion air supply, house air-tightness, exhaust fan operation, cracked heat exchangers, vent blockages, and flue pipe damage. Test data on CO emissions is presented from a wide range of sources including Brookhaven National Laboratory, Gas Research Institute, American Gas Association, the US Environmental Protection Agency, and the US Consumer Product Safety Commission for many potential CO sources in and near the home.« less

  10. Aerosol volatility in a boreal forest environment

    NASA Astrophysics Data System (ADS)

    Häkkinen, S. A. K.; ńijälä, M.; Lehtipalo, K.; Junninen, H.; Virkkula, A.; Worsnop, D. R.; Kulmala, M.; Petäjä, T.; Riipinen, I.

    2012-04-01

    during spring and autumn 2008. Results from the aerosol mass spectrometry indicate that the non-volatile residual consists of nitrate and organic compounds, especially during autumn. These compounds may be low-volatile organic nitrates or salts. During winter and spring the non-volatile core (black carbon removed) correlated markedly with carbon monoxide, which is a tracer of anthropogenic emissions. Due to this, the non-volatile residual may also contain other pollutants in addition to black carbon. Thus, it seems that the amount of different compounds in submicron aerosol particles varies with season and as a result the chemical composition of the non-volatile residual changes within a year. This work was supported by University of Helsinki three-year research grant No 490082 and Maj and Tor Nessling Foundation grant No 2010143. Aalto et al., (2001). Physical characterization of aerosol particles during nucleation events. Tellus B, 53, 344-358. Jayne, et al., (2000). Development of an aerosol mass spectrometer for size and composition analysis of submicron particles. Aerosol Sci. Technol., 33(1-2), 49-70. Kalberer et al., (2004). Identification of Polymers as Major Components of Atmospheric Organic Aerosols. Science, 303, 1659-1662. Smith et al., (2010). Observations of aminium salts in atmospheric nanoparticles and possible climatic implications. P. Natl. Acad. Sci., 107(15). Vesala et al., (1998). Long-term field measurements of atmosphere-surface interactions in boreal forest combining forest ecology, micrometeorology, aerosol physics and atmospheric chemistry. Trends Heat, Mass Mom. Trans., 4, 17-35. Wehner et al., (2002). Design and calibration of a thermodenuder with an improved heating unit to measure the size-dependent volatile fraction of aerosol particles. J. Aerosol Sci., 33, 1087-1093.

  11. Follow the Carbon: Isotopic Labeling Studies of Early Earth Aerosol.

    PubMed

    Hicks, Raea K; Day, Douglas A; Jimenez, Jose L; Tolbert, Margaret A

    2016-11-01

    Despite the faint young Sun, early Earth might have been kept warm by an atmosphere containing the greenhouse gases CH 4 and CO 2 in mixing ratios higher than those found on Earth today. Laboratory and modeling studies suggest that an atmosphere containing these trace gases could lead to the formation of organic aerosol haze due to UV photochemistry. Chemical mechanisms proposed to explain haze formation rely on CH 4 as the source of carbon and treat CO 2 as a source of oxygen only, but this has not previously been verified experimentally. In the present work, we use isotopically labeled precursor gases and unit-mass resolution (UMR) and high-resolution (HR) aerosol mass spectrometry to examine the sources of carbon and oxygen to photochemical aerosol formed in a CH 4 /CO 2 /N 2 atmosphere. UMR results suggest that CH 4 contributes 70-100% of carbon in the aerosol, while HR results constrain the value from 94% to 100%. We also confirm that CO 2 contributes approximately 10% of the total mass to the aerosol as oxygen. These results have implications for the geochemical interpretations of inclusions found in Archean rocks on Earth and for the astrobiological potential of other planetary atmospheres. Key Words: Atmosphere-Early Earth-Planetary atmospheres-Carbon dioxide-Methane. Astrobiology 16, 822-830.

  12. Performance of a fire detector based on a compact laser spectroscopic carbon monoxide sensor.

    PubMed

    Hangauer, A; Chen, J; Strzoda, R; Fleischer, M; Amann, M-C

    2014-06-02

    In this paper we show the suitability of a miniaturized tunable diode laser spectroscopy (TDLS)-based carbon-monoxide (CO) sensor for fire detection applications. The sensor utilizes a vertical-cavity surface-emitting laser (VCSEL) and inherent calibration scheme with reference gas filled in the photodetector housing. The fire-detection experiments are carried out under realistic conditions as described in the European standard EN54. The CO generation of all class C fires (according to EN54) could be well resolved. The cross-sensitivity to other substances was found to be very low: the maximum CO false response from cigarette smoke, hairspray and general aerosols reaches a low value of a few μL/L and only if the substance is directly applied into the sensor gas inlet. Therefore this sensor overcomes the disadvantage of high false alarm rate given by smoke detectors and is also in small size which is suitable for household and industrial applications. Hence, the VCSEL-based TDLS sensor is shown to have sufficient performance for fire-detection. It has advantages such as capability for fail-safe operation and, low cross-sensitivities as compared to existing point fire detector technology which is presently limited by these factors.

  13. The effects of reduced oxygen and of carbon monoxide on performance in a mouse pole-jump apparatus

    NASA Technical Reports Server (NTRS)

    Cagliostro, D. E.; Islas, A.

    1982-01-01

    The effects on reaction time and behavior were studied for exposure to reduced oxygen concentrations in the presence and absence of carbon monoxide. Tests were run with Swiss Webster mice in a pole-jump apparatus. The results show that reaction times increase gradually with a decrease in oxygen (O2) to 10 percent O2. Below 10 percent O2 reaction times increase dramatically and performance is degraded almost immediately. At carbon monoxide (CO) concentrations of 500 ppm and reduced O2 levels, reaction times are increased even more. At CO concentrations of 1000 ppm, performance is nearly completely degraded even without reduced oxygen levels.

  14. Evaluation of Length-of-Stain Gas Indicator Tubes for Measuring Carbon Monoxide in Air

    DOT National Transportation Integrated Search

    1971-11-01

    Techniques for detection and measurement of carbon monoxide (CO) in air are of interest and utility in many aspects of automotive safety. CO concentrations may range from less than 100 parts per million (ppm), or 0.01 percent, to about 10 percent by ...

  15. Identical linkage and cooperativity of oxygen and carbon monoxide binding to Octopus dofleini hemocyanin

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Connelly, P.R.; Gill, S.J.; Miller, K.I.

    1989-02-21

    Employment of high-precision thin-layer methods has enabled detailed functional characterization of oxygen and carbon monoxide binding for (1) the fully assembled form with 70 binding sites and (2) the isolated chains with 7 binding sites of octopus dofleini hemocyanin. The striking difference in the cooperativities of the two ligands for the assembled decamer is revealed through an examination of the binding capacities and the partition coefficient, determined as functions of the activities of both ligands. A global analysis of the data sets supported by a two-state allosteric model assuming an allosteric unit of 7. Higher level allosteric interactions were notmore » indicated. This contrasts to results obtained for arthropod hemocyanins. Oxygen and carbon monoxide experiments performed on the isolated subunit chain confirmed the presence of functional heterogeneity reported previously. The analysis shows two types of binding sites in the ratio of 4:3.« less

  16. The effect of ambient conditions on carbon monoxide emissions from an idling gas turbine combustor. M.S. Thesis

    NASA Technical Reports Server (NTRS)

    Subramanian, A. K.

    1977-01-01

    A test program employing a gas turbine combustor is outlined; the results of which quantize the effects of changes in ambient temperature and humidity on carbon monoxide emissions at simulated idle operating conditions. A comparison of the experimental results with analytical results generated by a kinetic model of the combustion process, and reflecting changing ambient conditions, is given. It is demonstrated that for a complete range of possible ambient variations, significant changes do occur in the amount of carbon monoxide emitted by a gas turbine at idle, and that the analytical model is reasonably successful in predicting changes.

  17. Cavity-enhanced quantum-cascade laser-based instrument for carbon monoxide measurements.

    PubMed

    Provencal, Robert; Gupta, Manish; Owano, Thomas G; Baer, Douglas S; Ricci, Kenneth N; O'Keefe, Anthony; Podolske, James R

    2005-11-01

    An autonomous instrument based on off-axis integrated cavity output spectroscopy has been developed and successfully deployed for measurements of carbon monoxide in the troposphere and tropopause onboard a NASA DC-8 aircraft. The instrument (Carbon Monoxide Gas Analyzer) consists of a measurement cell comprised of two high-reflectivity mirrors, a continuous-wave quantum-cascade laser, gas sampling system, control and data-acquisition electronics, and data-analysis software. CO measurements were determined from high-resolution CO absorption line shapes obtained by tuning the laser wavelength over the R(7) transition of the fundamental vibration band near 2172.8 cm(-1). The instrument reports CO mixing ratio (mole fraction) at a 1-Hz rate based on measured absorption, gas temperature, and pressure using Beer's Law. During several flights in May-June 2004 and January 2005 that reached altitudes of 41,000 ft (12.5 km), the instrument recorded CO values with a precision of 0.2 ppbv (1-s averaging time) and an accuracy limited by the reference CO gas cylinder (uncertainty < 1.0%). Despite moderate turbulence and measurements of particulate-laden airflows, the instrument operated consistently and did not require any maintenance, mirror cleaning, or optical realignment during the flights.

  18. 40 CFR 50.8 - National primary ambient air quality standards for carbon monoxide.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 2 2010-07-01 2010-07-01 false National primary ambient air quality standards for carbon monoxide. 50.8 Section 50.8 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS NATIONAL PRIMARY AND SECONDARY AMBIENT AIR QUALITY STANDARDS § 50.8 National primary ambient air quality standards for...

  19. 40 CFR 50.8 - National primary ambient air quality standards for carbon monoxide.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 2 2014-07-01 2014-07-01 false National primary ambient air quality standards for carbon monoxide. 50.8 Section 50.8 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS NATIONAL PRIMARY AND SECONDARY AMBIENT AIR QUALITY STANDARDS § 50.8 National primary ambient air quality standards for...

  20. 40 CFR 50.8 - National primary ambient air quality standards for carbon monoxide.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 2 2012-07-01 2012-07-01 false National primary ambient air quality standards for carbon monoxide. 50.8 Section 50.8 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS NATIONAL PRIMARY AND SECONDARY AMBIENT AIR QUALITY STANDARDS § 50.8 National primary ambient air quality standards for...

  1. 77 FR 31351 - Adequacy Determination for Aspen PM10 and Fort Collins Carbon Monoxide Maintenance Plans' Motor...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-05-25

    ...[bdi1][bdi0] and Fort Collins Carbon Monoxide Maintenance Plans' Motor Vehicle Emissions Budgets for... Aspen Attainment/Maintenance Area'' \\1\\ and its motor vehicle emissions budget, and the ``Revised Carbon... which we determine whether a SIP revision's motor vehicle emissions budget (MVEB) is adequate for...

  2. Remote detection of carbon monoxide by FTIR for simulating field detection in industrial process

    NASA Astrophysics Data System (ADS)

    Gao, Qiankun; Liu, Wenqing; Zhang, Yujun; Gao, Mingguang; Xu, Liang; Li, Xiangxian; Jin, Ling

    2016-10-01

    In order to monitor carbon monoxide in industrial production, we developed a passive gas radiation measurement system based on Fourier transform infrared spectroscopy and carried out infrared radiation measurement experiment of carbon monoxide detection in simulated industrial production environment by this system. The principle, condition, device and data processing method of the experiment are introduced in this paper. In order to solve the problem of light path jitter in the actual industrial field, we simulated the noise in the industrial environment. We combine the advantages of MATHEMATICA software in the aspects of graph processing and symbolic computation to data processing to improve the signal noise ratio and noise suppression. Based on the HITRAN database, the nonlinear least square fitting method was used to calculate the concentration of the CO spectra before and after the data processing. By comparing the calculated concentration, the data processed by MATHEMATICA is reliable and necessary in the industrial production environment.

  3. The impact of biogenic carbon emissions on aerosol absorption inMexico City

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Marley, N; Gaffney, J; Tackett, M J

    2009-02-24

    In order to determine the wavelength dependence of atmospheric aerosol absorption in the Mexico City area, the absorption angstrom exponents (AAEs) were calculated from aerosol absorption measurements at seven wavelengths obtained with a seven-channel aethalometer during two field campaigns, the Mexico City Metropolitan Area study in April 2003 (MCMA 2003) and the Megacity Initiative: Local and Global Research Observations in March 2006 (MILAGRO). The AAEs varied from 0.76 to 1.56 in 2003 and from 0.54 to 1.52 in 2006. The AAE values determined in the afternoon were consistently higher than the corresponding morning values, suggesting the photochemical formation of absorbingmore » secondary organic aerosols (SOA) in the afternoon. The AAE values were compared to stable and radiocarbon isotopic measurements of aerosol samples collected at the same time to determine the sources of the aerosol carbon. The fraction of modern carbon (fM) in the aerosol samples, as determined from {sup 14}C analysis, showed that 70% of the carbonaceous aerosols in Mexico City were from modern sources, indicating a significant impact from biomass burning during both field campaigns. The {sup 13}C/{sup 12}C ratios of the aerosol samples illustrate the significant impact of Yucatan forest fires (C-3 plants) in 2003 and local grass fires (C-4 plants) at site T1 in 2006. A direct comparison of the fM values, stable carbon isotope ratios, and calculated aerosol AAEs suggested that the wavelength dependence of the aerosol absorption was controlled by the biogenically derived aerosol components.« less

  4. Carbon monoxide exposure from aircraft fueling vehicles.

    PubMed

    McCammon, C S; Halperin, W F; Lemen, R A

    1981-01-01

    Investigators from the National Institute for Occupational Safety and Health observed deficiencies in maintenance of fueling trucks at an international airport. The exhaust system is vented under the front bumper, a standard design on fueling trucks which is intended to minimize the proximity of the exhaust system to the jet fuel in the vehicles. Carbon monoxide levels were measured in the cabs of 17 fueling trucks with windows closed, heaters on, and in different positions relative to the wind. One truck had an average CO level of 300 ppm, two exceeded 100 ppm, five others exceeded 50 ppm, while levels in the other nine averaged less than or equal to 500 ppm. Levels of CO depended on the mechanical condition of the vehicle and the vehicle's orientation to the wind. Stringent maintenance is required as the exhaust design is not fail-safe.

  5. 78 FR 48611 - Approval and Promulgation of State Implementation Plans: Alaska; Fairbanks Carbon Monoxide...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-08-09

    ... rule. SUMMARY: The EPA is taking direct final action to approve a carbon monoxide (CO) Limited... maintain the CO National Ambient Air Quality Standards (NAAQS) through the second 10-year maintenance..., Suite 900, Seattle, WA 98101. Hand Delivery/Courier: U.S. EPA Region 10, 1200 Sixth Avenue, Suite 900...

  6. Operations and maintenance manual, atmospheric contaminant sensor. Addendum 1: Carbon monoxide monitor model 204

    NASA Technical Reports Server (NTRS)

    1972-01-01

    An instrument for monitoring the carbon monoxide content of the ambient atmosphere is described. The subjects discussed are: (1) theory of operation, (2) system features, (3) controls and monitors, (4) operational procedures, and (5) maintenance and troubleshooting. Block drawings and circuit diagrams are included to clarify the text.

  7. Room-temperature cold-welding of gold nanoparticles for enhancing the electrooxidation of carbon monoxide.

    PubMed

    Liu, Cai; Li, Yong-Jun; Sun, Shi-Gang; Yeung, Edward S

    2011-04-21

    A cold-welding strategy is proposed to rapidly join together Au nanoparticles (AuNPs) into two-dimensional continuous structures for enhancing the electrooxidation of carbon monoxide by injecting a mixture of ethanol and tolulene into the bottom of a AuNP solution. © The Royal Society of Chemistry 2011

  8. Research and development of a luminol-carbon monoxide flow system

    NASA Technical Reports Server (NTRS)

    Thomas, R. R.

    1977-01-01

    Adaption of the luminol-carbon monoxide injection system to a flowing type system is reported. Analysis of actual wastewater samples was carried out and revealed that bacteria can be associated with particles greater than 10 microns in size in samples such as mixed liquor. Research into the luminol reactive oxidation state indicates that oxidized iron porphyrins, cytochrome-c in particular, produce more luminol chemiluminescence than the reduced form. Correlation exists between the extent of porphyrin oxidation and relative chemiluminescence. In addition, the porphyrin nucleus is apparently destroyed under the current chemiluminescent reaction conditions.

  9. Effect of multi-walled carbon nanotubes aspect ratio and temperature on the dielectric behavior of alternating alkene-carbon monoxide polyketone nanocomposites

    NASA Astrophysics Data System (ADS)

    Abu-Surrah, Adnan S.; Abdul Jawad, Saadi; Al-Ramahi, Esraa; Hallak, Awni B.; Khattari, Z.

    2015-04-01

    New alternating poly(propylene-alt-carbon monoxide/ethylene-alt-carbon monoxide) (PECO)/multiwalled carbon nanotubes (MWCNTs) composites have been prepared. Dielectric permittivity, electric modulus and ac conductivity of the isolated materials were investigated as a function of fiber aspect ratio, frequency and temperature. For aspect ratio of 30 and 200, a transition from insulator to semiconductor was observed at frequency 1×104. However, for high aspect ratio sample (660), no transition was observed and the conductivity is frequency independent in the measured frequency range of 10-106 Hz. The conductivity increases from about 1×10-4 for the sample that contain fibers of aspect ratio 30 and reaches 5×10-2 (Ω m)-1 for aspect ratio was 660. This behavior can be modeled by a circuit that consists of a contact resistance in series with a parallel combination of resistance (R) and capacitance (C). The calculated activation energy for sample filled with fibers having aspect ratio 30 is about 0.26 eV and decreases to about 0.16 eV when the aspect ratio is 660.

  10. Determining the diagnostic value of endogenous carbon monoxide in chronic obstructive pulmonary disease exacerbations.

    PubMed

    Dogan, Nurettin Özgür; Corbacioglu, Seref Kerem; Bildik, Fikret; Kilicaslan, Isa; Günaydin, Gül Pamukcu; Cevik, Yunsur; Ülker, Volkan; Hakoglu, Onur; Gökcen, Emre

    2014-09-01

    To determine whether endogenous carbon monoxide levels in exacerbations of Chronic Obstructive Pulmonary Disease patients were higher compared to healthy individuals and to investigate alteration of carbon monoxide levels across the three different severity stages of Global Initiative for Chronic Obstructive Lung Disease criteria related to Chronic Obstructive Pulmonary Disease exacerbations. The prospective study was conducted from January to March 2011 at two medical institutions in Ankara, Turkey, and comprised patients of acute Chronic Obstructive Pulmonary Disease exacerbations. The severity of the exacerbations was based on the Global Initiative for Chronic Obstructive Lung Disease criteria. Patients with active tobacco smoking, suspicious carbon monoxide poisoning and uncertain diagnosis were excluded. healthy control subjects who did not have any comorbid diseases and smoking habitus were also enrolled to compare the differences between carboxyhaemoglobin levels A two-tailed Mann-Whitney U test with Bonferroni correction was done following a Kruskal-Wallis test for statistical purposes. There were 90 patients and 81 controls in the study. Carboxyhaemoglobin levels were higher in the patients than the controls (p < 0.001). As for the three severity stages, Group 1 had a median carboxyhaemoglobin of 1.6 (0.95- 2.00). The corresponding levels in Group 2 (1.8 [1.38-2.20]) and Group 3 (1.9 [1.5-3.0]) were higher than the controls (p < 0.001 and p < 0.005 respectively). No statistically significant difference between Group 1 and the controls (1.30 [1.10-1.55]) was observed (p < 0.434). Carboxyhaemoglobin levels were significantly higher in exacerbations compared with the normal population. Also, in more serious exacerbations, carboxyhaemoglobin levels were significantly increased compared with healthy individuals and mild exacerbations.

  11. Long term aerosol and trace gas measurements in Central Amazonia

    NASA Astrophysics Data System (ADS)

    Artaxo, Paulo; Barbosa, Henrique M. J.; Ferreira de Brito, Joel; Carbone, Samara; Rizzo, Luciana V.; Andreae, Meinrat O.; Martin, Scot T.

    2016-04-01

    The central region of the Amazonian forest is a pristine region in terms of aerosol and trace gases concentrations. In the wet season, Amazonia is actually one of the cleanest continental region we can observe on Earth. A long term observational program started 20 years ago, and show important features of this pristine region. Several sites were used, between then ATTO (Amazon Tall Tower Observatory) and ZF2 ecological research site, both 70-150 Km North of Manaus, receiving air masses that traveled over 1500 km of pristine tropical forests. The sites are GAW regional monitoring stations. Aerosol chemical composition (OC/EC and trace elements) is being analysed using filters for fine (PM2.5) and coarse mode aerosol as well as Aerodyne ACSM (Aerosol Chemical Speciation Monitors). VOCs are measured using PTR-MS, while CO, O3 and CO2 are routinely measured. Aerosol absorption is being studied with AE33 aethalometers and MAAP (Multi Angle Absorption Photometers). Aerosol light scattering are being measured at several wavelengths using TSI and Ecotech nephelometers. Aerosol size distribution is determined using scanning mobility particle sizer at each site. Lidars measure the aerosol column up to 12 Km providing the vertical profile of aerosol extinction. The aerosol column is measures using AERONET sun photometers. In the wet season, organic aerosol comprises 75-85% of fine aerosol, and sulfate and nitrate concentrations are very low (1-3 percent). Aerosols are dominated by biogenic primary particles as well as SOA from biogenic precursors. Black carbon in the wet season accounts for 5-9% of fine mode aerosol. Ozone in the wet season peaks at 10-12 ppb at the middle of the day, while carbon monoxide averages at 50-80 ppb. Aerosol optical thickness (AOT) is a low 0.05 to 0.1 at 550 nm in the wet season. Sahara dust transport events sporadically enhance the concentration of soil dust aerosols and black carbon. In the dry season (August-December), long range transported

  12. Carbon monoxide – physiology, detection and controlled release

    PubMed Central

    Heinemann, Stefan H.; Hoshi, Toshinori; Westerhausen, Matthias

    2014-01-01

    Carbon monoxide (CO) is increasingly recognized as a cell-signalling molecule akin to nitric oxide (NO). CO has attracted particular attention as a potential therapeutic agent because of its reported anti-hypertensive, anti-inflammatory and cell-protective effects. We discuss recent progress in identifying new effector systems and elucidating the mechanisms of action of CO on, e.g., ion channels, as well as the design of novel methods to monitor CO in cellular environments. We also report on recent developments in the area of CO-releasing molecules (CORMs) and materials for controlled CO application. Novel triggers for CO release, metal carbonyls and degradation mechanisms of CORMs, are highlighted. In addition, potential formulations of CORMs for targeted CO release are discussed. PMID:24556640

  13. Palladium-catalyzed double carbonylation using near stoichiometric carbon monoxide: expedient access to substituted 13C2-labeled phenethylamines.

    PubMed

    Nielsen, Dennis U; Neumann, Karoline; Taaning, Rolf H; Lindhardt, Anders T; Modvig, Amalie; Skrydstrup, Troels

    2012-07-20

    A novel and general approach for (13)C(2)- and (2)H-labeled phenethylamine derivatives has been developed, based on a highly convergent single-step assembly of the carbon skeleton. The efficient incorporation of two carbon-13 isotopes into phenethylamines was accomplished using a palladium-catalyzed double carbonylation of aryl iodides with near stoichiometric carbon monoxide.

  14. [Estimation of carbon monoxide poisonings frequency, based on carboxyhemoglobin determinations performed in Toxicology Laboratory in Krakow in years 2002-2010].

    PubMed

    Gomółka, Ewa; Gawlikowski, Tomasz

    2011-01-01

    Carboxyhemoglobin is a specific biomarker of carbon monoxide (CO) exposition. The source of CO indoors are most often gas, oil or carbon furnaces and stoves or bathroom gas heaters. CO intoxication during fire or exposition to car fumes are sporadic. The aim of the study was: to present the frequency of CO intoxications diagnosed in Laboratory of Analytical Toxicology UJ Collegium Medicum in years 2002 - 2010, to present the season trends of CO intoxications, show sex and age structure of CO intoxicated patients. Material were Laboratory of Analytical Toxicology and Drug Monitoring data records from years 2002 - 2010. CO intoxication was confirmed and recognized when COHb blood concentration was higher than 10%. Annual number of CO poisonings was stable in the period of time, varied from 209 to 296 (mean 256,2 CO poisonings per year). Sex structure of CO poisoned patients showed little female dominance (54.6%). Carbon monoxide poisonings distribution was seasonal. The season of intensified CO intoxications lasted from October to March, the highest intensity was in December and January. The CO poisoning problem is still actual. Society education about security, recognition, diagnosis and practice in carbon monoxide exposition is still needful.

  15. Black Carbon Concentration from Worldwide Aerosol Robotic Network (AERONET)

    NASA Technical Reports Server (NTRS)

    Schuster, Greg; Dubovik, Oleg; Holben, Brent; Clothiaux, Eugene

    2008-01-01

    Worldwide black carbon concentration measurements are needed to assess the efficacy of the carbon emissions inventory and transport model output. This requires long-term measurements in many regions, as model success in one region or season does not apply to all regions and seasons. AERONET is an automated network of more than 180 surface radiometers located throughout the world. The sky radiance measurements obtained by AERONET are inverted to provide column-averaged aerosol refractive indices and size distributions for the AERONET database, which we use to derive column-averaged black carbon concentrations and specific absorptions that are constrained by the measured radiation field. This provides a link between AERONET sky radiance measurements and the elemental carbon concentration of transport models without the need for an optics module in the transport model. Knowledge of both the black carbon concentration and aerosol absorption optical depth (i.e., input and output of the optics module) will enable improvements to the transport model optics module.

  16. Black carbon aerosol mixing state, organic aerosols and aerosol optical properties over the UK

    NASA Astrophysics Data System (ADS)

    McMeeking, G. R.; Morgan, W. T.; Flynn, M.; Highwood, E. J.; Turnbull, K.; Haywood, J.; Coe, H.

    2011-05-01

    Black carbon (BC) aerosols absorb sunlight thereby leading to a positive radiative forcing and a warming of climate and can also impact human health through their impact on the respiratory system. The state of mixing of BC with other aerosol species, particularly the degree of internal/external mixing, has been highlighted as a major uncertainty in assessing its radiative forcing and hence its climate impact, but few in situ observations of mixing state exist. We present airborne single particle soot photometer (SP2) measurements of refractory BC (rBC) mass concentrations and mixing state coupled with aerosol composition and optical properties measured in urban plumes and regional pollution over the UK. All data were obtained using instrumentation flown on the UK's BAe-146-301 large Atmospheric Research Aircraft (ARA) operated by the Facility for Airborne Atmospheric Measurements (FAAM). We measured sub-micron aerosol composition using an aerosol mass spectrometer (AMS) and used positive matrix factorization to separate hydrocarbon-like (HOA) and oxygenated organic aerosols (OOA). We found a higher number fraction of thickly coated rBC particles in air masses with large OOA relative to HOA, higher ozone-to-nitrogen oxides (NOx) ratios and large concentrations of total sub-micron aerosol mass relative to rBC mass concentrations. The more ozone- and OOA-rich air masses were associated with transport from continental Europe, while plumes from UK cities had higher HOA and NOx and fewer thickly coated rBC particles. We did not observe any significant change in the rBC mass absorption efficiency calculated from rBC mass and light absorption coefficients measured by a particle soot absorption photometer despite observing significant changes in aerosol composition and rBC mixing state. The contributions of light scattering and absorption to total extinction (quantified by the single scattering albedo; SSA) did change for different air masses, with lower SSA observed in

  17. Anesthesia-related Carbon Monoxide Exposure: Toxicity and Potential Therapy

    PubMed Central

    Levy, Richard J.

    2016-01-01

    Exposure to carbon monoxide (CO) during general anesthesia can result from volatile anesthetic degradation by carbon dioxide absorbents as well as re-breathing of endogenously produced CO. Although adherence to the Anesthesia Patient Safety Foundation guidelines reduces the risk of CO poisoning, patients may still experience a sub-toxic CO exposure during low-flow anesthesia. The consequences of such exposures are relatively unknown. In contrast to the widely recognized toxicity of high CO concentrations, the biological activity of low concentration CO has recently been shown be cytoprotective. As such, low dose CO is being explored as a novel treatment for a variety of different diseases. Here we review the concept of anesthesia-related CO exposure, identify the sources of production, detail the mechanisms of overt CO toxicity, highlight the cellular effects of low dose CO, and discuss the potential therapeutic role for CO as a part of routine anesthetic management. PMID:27537758

  18. Effects of morphology on the radiative properties of internally mixed light absorbing carbon aerosols with different aging status.

    PubMed

    Cheng, Tianhai; Wu, Yu; Chen, Hao

    2014-06-30

    Light absorbing carbon aerosols play a substantial role in climate change through radiative forcing, which is the dominant absorber of solar radiation. Radiative properties of light absorbing carbon aerosols are strongly dependent on the morphological factors and the mixing mechanism of black carbon with other aerosol components. This study focuses on the morphological effects on the optical properties of internally mixed light absorbing carbon aerosols using the numerically exact superposition T-matrix method. Three types aerosols with different aging status such as freshly emitted BC particles, thinly coated light absorbing carbon aerosols, heavily coated light absorbing carbon aerosols are studied. Our study showed that morphological factors change with the aging of internally mixed light absorbing carbon aerosols to result in a dramatic change in their optical properties. The absorption properties of light absorbing carbon aerosols can be enhanced approximately a factor of 2 at 0.67 um, and these enhancements depend on the morphological factors. A larger shell/core diameter ratio of volume-equivalent shell-core spheres (S/C), which indicates the degree of coating, leads to stronger absorption. The enhancement of absorption properties accompanies a greater enhancement of scattering properties, which is reflected in an increase in single scattering albedo (SSA). The enhancement of single scattering albedo due to the morphological effects can reach a factor of 3.75 at 0.67 μm. The asymmetry parameter has a similar yet smaller enhancement. Moreover, the corresponding optical properties of shell-and-core model determined by using Lorenz -Mie solutions are presented for comparison. We found that the optical properties of internally mixed light absorbing carbon aerosol can differ fundamentally from those calculated for the Mie theory shell-and-core model, particularly for thinly coated light absorbing carbon aerosols. Our studies indicate that the complex morphology

  19. Cardiovascular Abnormalities in Carbon Monoxide Poisoning.

    PubMed

    Garg, Jalaj; Krishnamoorthy, Parasuram; Palaniswamy, Chandrasekar; Khera, Sahil; Ahmad, Hasan; Jain, Diwakar; Aronow, Wilbert S; Frishman, William H

    Acute carbon monoxide (CO) poisoning is the most common cause of poisoning and poisoning-related death in the United States. It manifests as broad spectrum of symptoms ranging from mild headache, nausea, and fatigue to dizziness, syncope, coma, seizures resulting in cardiovascular collapse, respiratory failure, and death. Cardiovascular complications of CO poisoning has been well reported and include myocardial stunning, left ventricular dysfunction, pulmonary edema, and arrhythmias. Acute myocardial ischemia has also been reported from increased thrombogenicity due to CO poisoning. Myocardial toxicity from CO exposure is associated with increased short-term and long-term mortality. Carboxyhemoglobin (COHb) levels do not correlate well with the clinical severity of CO poisoning. Supplemental oxygen remains the cornerstone of therapy for CO poisoning. Hyperbaric oxygen therapy increases CO elimination and has been used with wide variability in patients with evidence of neurological and myocardial injury from CO poisoning, but its benefit in limiting or reversing cardiac injury is unknown. We present a comprehensive review of literature on cardiovascular manifestations of CO poisoning and propose a diagnostic algorithm for managing patients with CO poisoning.

  20. [Outbreak of carbon monoxide poisoning in the Ile-de-France region during the spring 2016 Seine flooding].

    PubMed

    Dufayet, Laurène; Médernach, Chantal; Bassi, Clément; Garnier, Robert; Langrand, Jérôme

    2017-01-01

    Heavy rainfall in May 2016 caused large-scale flooding of the Seine and its tributaries. Analysis of this unusual event showed that it could recur on an even larger scale. The sanitary consequences were less frequently assessed in this analysis, particularly the risk of accidental collective carbon monoxide (CO) poisoning caused by the use of combustion engine drainage pumps. We retrospectively reviewed all cases of acute accidental carbon monoxide exposure observed in the Ile-de-France region, related to the use of drainage pumps in spring and summer 2016 and notified to the Ile-de-France CO poisoning surveillance network. Five events were identified, including 45 people exposed to carbon monoxide. Thirty-four of these people were poisoned, 5 were not poisoned and insufficient data were available for 6 people. Three people showed signs of severity and 2 were treated by hyperbaric oxygen therapy. The other poisoned individuals were managed in hospital and treated by oxygen therapy. All were cured. Collective CO poisonings are common sanitary events during flooding and can be potentially severe. They can occur during the event or over the following days. Preventive measures may help to reduce the risk of CO poisoning, such as increased awareness among professionals, better information of individuals who rent these types of devices or even the use of CO detectors during their use.

  1. Sublimation rates of carbon monoxide and carbon dioxide from comet nuclei at large distances from the Sun

    NASA Technical Reports Server (NTRS)

    Sekanina, Zdenek

    1991-01-01

    One of the more attractive among the plausible scenarios for the major emission event recently observed on Comet Halley at a heliocentric distance of 14.3 AU is activation of a source of ejecta driven by an icy substance much more volatile than water. As prerequisite for the forthcoming detailed analysis of the imaging observations of this event, a simple model is proposed that yields the sublimation rate versus time at any location on the surface of a rotating cometary nucleus for two candidate ices: carbon monoxide and carbon dioxide. The model's variable parameters are the comet's heliocentric distance r and the Sun's instantaneous zenith angle z.

  2. The climatology of carbon monoxide and water vapor on Mars as observed by CRISM and modeled by the GEM-Mars general circulation model

    NASA Astrophysics Data System (ADS)

    Smith, Michael D.; Daerden, Frank; Neary, Lori; Khayat, Alain

    2018-02-01

    Radiative transfer modeling of near-infrared spectra taken by the Compact Reconnaissance Imaging Spectrometer for Mars (CRISM) instrument onboard Mars Reconnaissance Orbiter (MRO) enables the column-integrated abundance of carbon monoxide (CO) and water vapor (H2O) to be retrieved. These results provide a detailed global description of the seasonal and spatial distribution of CO in the Mars atmosphere and new information about the interannual variability of H2O. The CRISM retrievals show the seasonally and globally averaged carbon monoxide mixing ratio to be near 800 ppm, but with strong seasonal variations, especially at high latitudes. At low latitudes, the carbon monoxide mixing ratio varies in response to the mean seasonal cycle of surface pressure and shows little variation with topography. At high latitudes, carbon monoxide is depleted in the summer hemisphere by a factor of two or more, while in the winter hemisphere there is relatively higher mixing ratio in regions with low-lying topography. Water vapor shows only modest interannual variations, with the largest observed difference being unusually dry conditions in the wake of the Mars Year 28 global dust storm. Modeling results from the GEM-Mars general circulation model generally reproduce the observed seasonal and spatial trends and provide insight into the underlying physical processes.

  3. Variations of time-to-incapacitation and carboxyhemoglobin values in rats exposed to two carbon monoxide concentrations.

    DOT National Transportation Integrated Search

    1993-05-01

    It has been suggested that passenger protective breathing equipment protect aircraft passengers from smoke for 5 min during an evacuation phase and for 35 min during an in-flight-plus-evacuation phase. Carbon monoxide (CO) is one of the most abundant...

  4. Historical (1850-2000) gridded anthropogenic and biomass burning emissions of reactive gases and aerosols:methodology and application

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lamarque, J. F.; Bond, Tami C.; Eyring, Veronika

    2010-08-11

    We present and discuss a new dataset of gridded emissions covering the historical period (1850-2000) in decadal increments at a horizontal resolution of 0.5° in latitude and longitude. The primary purpose of this inventory is to provide consistent gridded emissions of reactive gases and aerosols for use in chemistry model simulations needed by climate models for the Climate Model Intercomparison Program #5 (CMIP5) in support of the Intergovernmental Panel on Climate Change (IPCC) Fifth Assessment report. Our best estimate for the year 2000 inventory represents a combination of existing regional and global inventories to capture the best information available atmore » this point; 40 regions and 12 sectors were used to combine the various sources. The historical reconstruction of each emitted compound, for each region and sector, was then forced to agree with our 2000 estimate, ensuring continuity between past and 2000 emissions. Application of these emissions into two chemistry-climate models is used to test their ability to capture long-term changes in atmospheric ozone, carbon monoxide and aerosols distributions. The simulated long-term change in the Northern mid-latitudes surface and mid-troposphere ozone is not quite as rapid as observed. However, stations outside this latitude band show much better agreement in both present-day and long-term trend. The model simulations consistently underestimate the carbon monoxide trend, while capturing the long-term trend at the Mace Head station. The simulated sulfate and black carbon deposition over Greenland is in very good agreement with the ice-core observations spanning the simulation period. Finally, aerosol optical depth and additional aerosol diagnostics are shown to be in good agreement with previously published estimates.« less

  5. Carbon monoxide measurement in the global atmospheric sampling program

    NASA Technical Reports Server (NTRS)

    Dudzinski, T. J.

    1979-01-01

    The carbon monoxide measurement system used in the NASA Global Atmospheric Sampling Program (GASP) is described. The system used a modified version of a commercially available infrared absorption analyzer. The modifications increased the sensitivity of the analyzer to 1 ppmv full scale, with a limit of detectability of 0.02 ppmv. Packaging was modified for automatic, unattended operation in an aircraft environment. The GASP system is described along with analyzer operation, calibration procedures, and measurement errors. Uncertainty of the CO measurement over a 2-year period ranged from + or - 3 to + or - 13 percent of reading, plus an error due to random fluctuation of the output signal + or - 3 to + or - 15 ppbv.

  6. An evaluation of a carbon monoxide poisoning education program.

    PubMed

    Schwartz, Lauren; Martinez, Luz; Louie, Jean; Mercurio-Zappala, Maria; Howland, Mary Ann; Nokes, Kathleen; Hoffman, Robert S

    2010-05-01

    Carbon monoxide (CO) is the leading cause of poisoning death in the United States. Research has shown that proper use of a CO detector in the home can reduce morbidity and mortality related to unintentional CO exposure. The authors evaluated three CO education workshops that included distribution of free CO detectors for home use, and their intervention reached 133 participants. Pretest surveys and follow-up calls evaluated change in knowledge and behavior factors. Results showed that statistically significant increases were found on three out of five knowledge-based items and 91% of respondents (N = 80) reported installing CO detectors in their home. Follow-up calls provided an opportunity to clarify information and provide tailored information to participants.

  7. Refractive Index and Absorption Attribution of Highly Absorbing Brown Carbon Aerosols from an Urban Indian City-Kanpur.

    PubMed

    Shamjad, P M; Tripathi, S N; Thamban, Navaneeth M; Vreeland, Heidi

    2016-11-24

    Atmospheric aerosols influence Earth's radiative balance, having both warming and cooling effects. Though many aerosols reflect radiation, carbonaceous aerosols such as black carbon and certain organic carbon species known as brown carbon have the potential to warm the atmosphere by absorbing light. Black carbon absorbs light over the entire solar spectrum whereas brown carbon absorbs near-UV wavelengths and, to a lesser extent, visible light. In developing countries, such as India, where combustion sources are prolific, the influence of brown carbon on absorption may be significant. In order to better characterize brown carbon, we present experimental and modeled absorption properties of submicron aerosols measured in an urban Indian city (Kanpur). Brown carbon here is found to be fivefold more absorbing at 365 nm wavelength compared to previous studies. Results suggest ~30% of total absorption in Kanpur is attributed to brown carbon, with primary organic aerosols contributing more than secondary organics. We report the spectral brown carbon refractive indices along with an experimentally constrained estimate of the influence of aerosol mixing state on absorption. We conclude that brown carbon in Kanpur is highly absorbing in nature and that the mixing state plays an important role in light absorption from volatile species.

  8. Refractive Index and Absorption Attribution of Highly Absorbing Brown Carbon Aerosols from an Urban Indian City-Kanpur

    PubMed Central

    Shamjad, P. M.; Tripathi, S. N.; Thamban, Navaneeth M.; Vreeland, Heidi

    2016-01-01

    Atmospheric aerosols influence Earth’s radiative balance, having both warming and cooling effects. Though many aerosols reflect radiation, carbonaceous aerosols such as black carbon and certain organic carbon species known as brown carbon have the potential to warm the atmosphere by absorbing light. Black carbon absorbs light over the entire solar spectrum whereas brown carbon absorbs near-UV wavelengths and, to a lesser extent, visible light. In developing countries, such as India, where combustion sources are prolific, the influence of brown carbon on absorption may be significant. In order to better characterize brown carbon, we present experimental and modeled absorption properties of submicron aerosols measured in an urban Indian city (Kanpur). Brown carbon here is found to be fivefold more absorbing at 365 nm wavelength compared to previous studies. Results suggest ~30% of total absorption in Kanpur is attributed to brown carbon, with primary organic aerosols contributing more than secondary organics. We report the spectral brown carbon refractive indices along with an experimentally constrained estimate of the influence of aerosol mixing state on absorption. We conclude that brown carbon in Kanpur is highly absorbing in nature and that the mixing state plays an important role in light absorption from volatile species. PMID:27883083

  9. Multiple Victims of Carbon Monoxide Poisoning in the Aftermath of a Wildfire: A Case Series.

    PubMed

    Santos, Luís Ramos; Alves-Correia, Magna; Câmara, Margarida; Lélis, Manuela; Caldeira, Carmo; Brazão, Maria Luz; Nóbrega, José Júlio

    2018-03-29

    Carbon monoxide poisoning may occur in several contexts. Retrospective of 37 carbon monoxide poisoning cases that underwent hyperbaric oxygen during wildfires in Funchal in August 2016. The studied sample included 37 patients, mean age of 38 years, 78% males. Ten were firefighters, four children and two pregnant victims. Neurological symptoms were the most reported. Median carboxyhemoglobin level was 3.7% (IQR 2.7). All received high-flow oxygen from admission to delivery of hyperbaric oxygen. Persistence of symptoms was the main indication for hyperbaric oxygen. Median time to hyperbaric oxygen was 4.8 hours (IQR 9.5), at 2.5 ATA for 90 minutes, without major complications. Discharge in less than 24 hours occurred in 92% of the cases. Thirty days follow-up: five patients presented clinical symptoms of late neurological syndrome; twelve patients were lost to follow-up. Carboxyhemoglobin levels on admission and mean time to hyperbaric oxygen were no different between those who did and did not develop the syndrome at 30 days (p = 0.44 and p = 0.58, respectively). Late neurological syndrome at 30 days occurred in 20% and no new cases were reported at 12 months. Use of hyperbaric oxygen appears to have reduced the incidence of the syndrome. This seems to be the first Portuguese series reporting use of hyperbaric oxygen in carbon monoxide poisoning due to wildfires. The authors intend to alert to the importance of referral of these patients because the indications and benefits of this treatment are well documented. This is especially important given the ever-growing issue of wildfires in Portugal.

  10. Integrated Science Assessment (ISA) for Carbon Monoxide ...

    EPA Pesticide Factsheets

    EPA announced that the First External Review Draft of the Integrated Science Assessment (ISA) for Carbon Monoxide (CO) and related Annexes was made available for independent peer review and public review. This draft ISA document represents a concise synthesis and evaluation of the most policy-relevant science and will ultimately provide the scientific bases for EPA's decision regarding whether the current standards for CO sufficiently protect public health and the environment. The Integrated Plan for Review of the NAAQS for CO {U.S. EPA, 2008 #8615} identifies key policy-relevant questions that provide a framework for this review of the scientific evidence. These questions frame the entire review of the NAAQS, and thus are informed by both science and policy considerations. The ISA organizes and presents the scientific evidence such that it, when considered along with findings from risk analyses and policy considerations, will help the EPA address these questions during the NAAQS review:

  11. High Altitude Emissions of Black Carbon Aerosols: Potential Climate Implications

    NASA Astrophysics Data System (ADS)

    Satheesh, S. K.

    2017-12-01

    Synthesizing a series of ground-based and airborne measurements of aerosols over the Indian region during summer and pre-monsoon seasons have revealed the persistence of elevated absorbing aerosol layers over most of the Indian region; more than 50% of which located above clouds. Subsequent, in situ measurements of black carbon (BC) using high-altitude balloons, showed surprising layers with high concentrations in the middle and upper troposphere even at an altitude of 8 to 10 kms. Simultaneous measurements of the vertical thermal structure have shown localized warming due to BC absorption leading to large reduction in lapse rate and sharp temperature inversion, which in turn increases the atmospheric stability. This aerosol-induced stable layer is conducive for maintaining the black carbon layer longer at that level, leading thereby to further solar absorption and subsequently triggering dry convection. These observations support the `solar escalator' concept through which absorption-warming-convection cycles lead to self-lifting of BC to upper troposphere or even to lower stratosphere under favorable conditions in a matter of a few days. Employing an on-line regional chemistry transport model (WRF-Chem), incorporating aircraft emissions, it is shown that emissions from high-flying aircrafts as the most likely source of these elevated black carbon layers. These in-situ injected particles, produce significant warming of the thin air in those heights and lift these layers to even upper tropospheric/lower stratospheric heights, aided by the strong monsoonal convection occurring over the region, which are known to overshoot the tropical tropopause leading to injection of tropospheric air mass (along with its constituent aerosols) into the stratosphere, especially during monsoon season when the tropical tropopause layer is known to be thinnest. These simulations are further supported by the CALIPSO space-borne LIDAR derived extinction coefficient profiles. Based on

  12. Black carbon aerosol mixing state, organic aerosols and aerosol optical properties over the United Kingdom

    NASA Astrophysics Data System (ADS)

    McMeeking, G. R.; Morgan, W. T.; Flynn, M.; Highwood, E. J.; Turnbull, K.; Haywood, J.; Coe, H.

    2011-09-01

    Black carbon (BC) aerosols absorb sunlight thereby leading to a positive radiative forcing and a warming of climate and can also impact human health through their impact on the respiratory system. The state of mixing of BC with other aerosol species, particularly the degree of internal/external mixing, has been highlighted as a major uncertainty in assessing its radiative forcing and hence its climate impact, but few in situ observations of mixing state exist. We present airborne single particle soot photometer (SP2) measurements of refractory BC (rBC) mass concentrations and mixing state coupled with aerosol composition and optical properties measured in urban plumes and regional pollution over the United Kingdom. All data were obtained using instrumentation flown on the UK's BAe-146-301 large Atmospheric Research Aircraft (ARA) operated by the Facility for Airborne Atmospheric Measurements (FAAM). We measured sub-micron aerosol composition using an aerosol mass spectrometer (AMS) and used positive matrix factorization to separate hydrocarbon-like (HOA) and oxygenated organic aerosols (OOA). We found a higher number fraction of thickly coated rBC particles in air masses with large OOA relative to HOA, higher ozone-to-nitrogen oxides (NOx) ratios and large concentrations of total sub-micron aerosol mass relative to rBC mass concentrations. The more ozone- and OOA-rich air masses were associated with transport from continental Europe, while plumes from UK cities had higher HOA and NOx and fewer thickly coated rBC particles. We did not observe any significant change in the rBC mass absorption efficiency calculated from rBC mass and light absorption coefficients measured by a particle soot absorption photometer despite observing significant changes in aerosol composition and rBC mixing state. The contributions of light scattering and absorption to total extinction (quantified by the single scattering albedo; SSA) did change for different air masses, with lower SSA

  13. Unsuccessful Suicide by Carbon Monoxide: A Secondary Benefit of Emissions Control

    PubMed Central

    Landers, Dennis

    1981-01-01

    Emission systems and devices are required on automobile engines to reduce air pollution problems. Catalytic converters have been used on most 1975 and newer automobiles to reduce hydrocarbon and carbon monoxide (CO) emissions to a value that meets the Environmental Protection Agency requirements established for 1975 and 1976. The 1980-1981 Boise, Idaho, study shows that with a functioning catalytic converter either unmeasurable or sublethal quantities of CO appear in automobile exhaust. Thus, emissions control has produced a secondary benefit in reducing the number of suicides by CO poisoning from automobile exhaust fumes. PMID:6176074

  14. Unsuccessful suicide by carbon monoxide: a secondary benefit of emissions control

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Landers, D.

    Emission systems and devices are required on automobile engines to reduce air pollution problems. Catalytic converters have been used on most 1975 and newer automobiles to reduce hydrocarbon and carbon monoxide (CO) emissions to a value that meets the Environmental Protection Agency requirements established for 1975 and 1976. The 1980-1981 Boise, Idaho, study shows that with a functioning catalytic converter either unmeasurable or sublethal quantities of CO appear in automobile exhaust. Thus, emissions control has produced a secondary benefit in reducing the number of suicides by CO poisoning from automobile exhaust fumes.

  15. Direct radiative effect due to brownness in organic carbon aerosols generated from biomass combustion

    NASA Astrophysics Data System (ADS)

    Rathod, T. D.; Sahu, S. K.; Tiwari, M.; Pandit, G. G.

    2016-12-01

    We report the enhancement in the direct radiative effect due the presence of Brown carbon (BrC) as a part of organic carbon aerosols. The optical properties of organic carbon aerosols generated from pyrolytic combustion of mango tree wood (Magnifera Indica) and dung cake at different temperatures were considered. Mie codes were used to calculate absorption and scattering coefficients coupled with experimentally derived imaginary complex refractive index. The direct radiative effect (DRE) for sampled organic carbon aerosols was estimated using a wavelength dependent radiative transfer equation. The BrC DRE was estimated taking virtually non absorbing organic aerosols as reference. The BrC DRE from wood and dung cake was compared at different combustion temperatures and conditions. The BrC contributed positively to the direct top of the atmosphere radiative effect. Dung cake generated BrC aerosols were found to be strongly light absorbing as compared to BrC from wood combustion. It was noted that radiative effects of BrC from wood depended on its generation temperature and conditions. For BrC aerosols from dung cake such strong dependence was not observed. The average BrC aerosol DRE values were 1.53±0.76 W g-1 and 17.84±6.45 W g-1 for wood and dung cake respectively. The DRE contribution of BrC aerosols came mainly (67-90%) from visible light absorption though they exhibited strong absorption in shorter wavelengths of the UV-visible spectrum.

  16. Chemical Composition of African Biomass Burning Aerosols Over the Southeast Atlantic: Aerosol Mass Spectrometer Results from the 2016 and 2017 ORACLES Field Campaigns.

    NASA Astrophysics Data System (ADS)

    Dobracki, A. N.; Howell, S. G.; Freitag, S.; Smirnow, N.; Podolske, J. R.

    2017-12-01

    Biomass burning (BB) is one of the largest contributors of anthropogenic aerosols in the atmosphere. During BB events, organic and inorganic gases and particles are emitted into the atmosphere. Because of their abundance, particle size, and radiative properties, BB aerosols play an important role in global climate. Southern Africa produces 30% of the Earth's BB aerosol particles. Organics, Nitrates, sulfates, and refractory black carbon, along with other chemical species are lofted into the free troposphere and transported over the Southeast Atlantic Ocean. However, considerate uncertainty remains in the chemical composition of these plumes with its large variety of organic and inorganic species. As part of the NASA ORACLES (ObseRvations of Aerosols above CLouds and their intEractionS) 2016 and 2017 airborne field campaigns, an Aerosol Mass Spectrometer (AMS) was used to sample the chemical composition and chemical structure of the aerosol in this region. Results show constant vertical stratification within the plume over the course of the campaign (August 2017 / September 2016). Using nitrate (NO3) and organic carbon (OC) as two tracers, the structure of the September 2016 plume had a ratio of 1:8 (NO3:OC) in the upper plume (3km-5km), while the lower plume (1km-2.5km) had a ratio of 1:12 (NO3:OC). AMS measurements were supported by carbon monoxide (CO) and carbon dioxide (CO2) measurements. This data revealed a modified combustion efficiency (MCE= ΔCO2/ΔCO2 + ΔCO) of <0.97 in the upper plume, and a higher MCE > 0.97 in the lower plume. An MCE above 0.9 represents efficient burning processes. Additionally, concentrations of C2(H2O)2 (m/z60), a common chemical fragment from breaking up carbohydrates (primarily levoglucosan) emitted by burning biomass only represented <1% of total organics throughout the campaign. These low concentrations are due to efficient combustion rather than oxidation during transport. These results are consistent with earlier studies of

  17. Biogenic influence on the composition and growth of summertime Arctic aerosol

    NASA Astrophysics Data System (ADS)

    Willis, M. D.; Burkart, J.; Thomas, J. L.; Koellner, F.; Schneider, J.; Bozem, H.; Hoor, P. M.; Aliabadi, A. A.; Schulz, H.; Herber, A. B.; Leaitch, R.; Abbatt, J.

    2016-12-01

    The summertime Arctic lower troposphere is a relatively pristine background aerosol environment dominated by nucleation and Aitken mode particles. Understanding the mechanisms that control the formation and growth of aerosol is crucial for our ability to predict cloud properties and therefore radiative balance and climate. We present aircraft-based observations of submicron aerosol composition from an aerosol mass spectrometer made during the NETCARE 2014 summertime arctic campaign, based in the Canadian High Arctic, at Resolute Bay, NU (74°N). Under stable and regionally influenced atmospheric conditions with low carbon monoxide and black carbon concentrations (< 100 ppbv and < 50 ng/m3, respectively), we observed organic aerosol (OA)-to-sulfate ratios ranging from 0.5 to > 6 with evidence for enhancement within the lower boundary layer. Methanesulfonic acid (MSA), a marker for the contribution of ocean-derived biogenic sulphur, was also observed in submicron aerosol. MSA-to-sulfate ratios ranged from near zero to 0.3 and tended to increase within the lower boundary layer, suggesting a contribution to aerosol loading from the ocean. In one notable case while flying in the lower boundary layer above open water in Lancaster Sound, we observed growth of small particles, <20 nm in diameter, into sizes above 50 nm. Aerosol growth was correlated with the presence of organic species, trimethylamine, and MSA in particles 80 nm and larger, where the organics were similar to those previously observed in marine settings. The organic-rich aerosol contributed significantly to particles active as cloud condensation nuclei (CCN, supersaturation = 0.6%). Our results highlight the potential importance of secondary organic aerosol formation and its role in growing nucleation mode aerosol into CCN-active sizes in this remote marine environment.

  18. Inorganic markers, carbonaceous components and stable carbon isotope from biomass burning aerosols in northeast China

    NASA Astrophysics Data System (ADS)

    Cao, F.; Zhang, Y.; Kawamura, K.

    2015-12-01

    To better characterize the sources of fine particulate matter (i.e. PM2.5) in Sanjiang Plain, Northeast China, aerosol chemical composition such total carbon (TC), organic carbon (OC), elemental carbon (EC), water-soluble organic carbon (WSOC), and inorganic ions were studied as well as stable carbon isotopic composition (δ13C) of TC. Intensively open biomass burning episodes were identified from late September to early October by satellite fire and aerosol optical depth maps. During the biomass burning episodes, concentrations of PM2.5, OC, EC, and WSOC increased by a factor of 4-12 compared to non-biomass-burning periods. Non-sea-salt potassium is strongly correlated with PM2.5, OC, EC and WSOC, suggesting an important contribution of biomass burning emission. The enrichment in both the non-sea-salt potassium and chlorine is significantly larger than other inorganic species, indicating that biomass burning aerosols in Sanjiang Plain is mostly fresh and less aged. In addition, WSOC to OC ratio is relatively lower compared to that reported in biomass burning aerosols in tropical regions, supporting that biomass burning aerosols in Sanjiang Plain is mostly primary and secondary organic aerosols is not significant. A lower average δ13C value (-26.2‰) is found for the biomass-burning aerosols, suggesting a dominant contribution from combustion of C3 plants in the studied region.

  19. Regulation of Multiple Carbon Monoxide Consumption Pathways in Anaerobic Bacteria

    PubMed Central

    Techtmann, Stephen M.; Colman, Albert S.; Murphy, Michael B.; Schackwitz, Wendy S.; Goodwin, Lynne A.; Robb, Frank T.

    2011-01-01

    Carbon monoxide (CO), well known as a toxic gas, is increasingly recognized as a key metabolite and signaling molecule. Microbial utilization of CO is quite common, evidenced by the rapid escalation in description of new species of CO-utilizing bacteria and archaea. Carbon monoxide dehydrogenase (CODH), the protein complex that enables anaerobic CO-utilization, has been well-characterized from an increasing number of microorganisms, however the regulation of multiple CO-related gene clusters in single isolates remains unexplored. Many species are extraordinarily resistant to high CO concentrations, thriving under pure CO at more than one atmosphere. We hypothesized that, in strains that can grow exclusively on CO, both carbon acquisition via the CODH/acetyl CoA synthase complex and energy conservation via a CODH-linked hydrogenase must be differentially regulated in response to the availability of CO. The CO-sensing transcriptional activator, CooA is present in most CO-oxidizing bacteria. Here we present a genomic and phylogenetic survey of CODH operons and cooA genes found in CooA-containing bacteria. Two distinct groups of CooA homologs were found: one clade (CooA-1) is found in the majority of CooA-containing bacteria, whereas the other clade (CooA-2) is found only in genomes that encode multiple CODH clusters, suggesting that the CooA-2 might be important for cross-regulation of competing CODH operons. Recombinant CooA-1 and CooA-2 regulators from the prototypical CO-utilizing bacterium Carboxydothermus hydrogenoformans were purified, and promoter binding analyses revealed that CooA-1 specifically regulates the hydrogenase-linked CODH, whereas CooA-2 is able to regulate both the hydrogenase-linked CODH and the CODH/ACS operons. These studies point to the ability of dual CooA homologs to partition CO into divergent CO-utilizing pathways resulting in efficient consumption of a single limiting growth substrate available across a wide range of concentrations. PMID

  20. Remote sensing of soot carbon - Part 1: Distinguishing different absorbing aerosol species

    NASA Astrophysics Data System (ADS)

    Schuster, G. L.; Dubovik, O.; Arola, A.

    2016-02-01

    We describe a method of using the Aerosol Robotic Network (AERONET) size distributions and complex refractive indices to retrieve the relative proportion of carbonaceous aerosols and free iron minerals (hematite and goethite). We assume that soot carbon has a spectrally flat refractive index and enhanced imaginary indices at the 440 nm wavelength are caused by brown carbon or hematite. Carbonaceous aerosols can be separated from dust in imaginary refractive index space because 95 % of biomass burning aerosols have imaginary indices greater than 0.0042 at the 675-1020 nm wavelengths, and 95 % of dust has imaginary refractive indices of less than 0.0042 at those wavelengths. However, mixtures of these two types of particles can not be unambiguously partitioned on the basis of optical properties alone, so we also separate these particles by size. Regional and seasonal results are consistent with expectations. Monthly climatologies of fine mode soot carbon are less than 1.0 % by volume for West Africa and the Middle East, but the southern African and South American biomass burning sites have peak values of 3.0 and 1.7 %. Monthly averaged fine mode brown carbon volume fractions have a peak value of 5.8 % for West Africa, 2.1 % for the Middle East, 3.7 % for southern Africa, and 5.7 % for South America. Monthly climatologies of free iron volume fractions show little seasonal variability, and range from about 1.1 to 1.7 % for coarse mode aerosols in all four study regions. Finally, our sensitivity study indicates that the soot carbon retrieval is not sensitive to the component refractive indices or densities assumed for carbonaceous and free iron aerosols, and the retrieval differs by only 15.4 % when these parameters are altered from our chosen baseline values. The total uncertainty of retrieving soot carbon mass is ˜ 50 % (when uncertainty in the AERONET product and mixing state is included in the analysis).

  1. Atmospheric Carbon Dioxide and Aerosols: Effects of Large Increases on Global Climate

    ERIC Educational Resources Information Center

    Science, 1971

    1971-01-01

    Mathematical models indicate increasing atmospheric carbon dioxide causes an increase in surface temperature at a decreasing rate, and the rate of temperature decrease caused by increasing aerosols increases with aerosol concentration. (AL)

  2. Estimation of black carbon content for biomass burning aerosols from multi-channel Raman lidar data

    NASA Astrophysics Data System (ADS)

    Talianu, Camelia; Marmureanu, Luminita; Nicolae, Doina

    2015-04-01

    Biomass burning due to natural processes (forest fires) or anthropical activities (agriculture, thermal power stations, domestic heating) is an important source of aerosols with a high content of carbon components (black carbon and organic carbon). Multi-channel Raman lidars provide information on the spectral dependence of the backscatter and extinction coefficients, embedding information on the black carbon content. Aerosols with a high content of black carbon have large extinction coefficients and small backscatter coefficients (strong absorption), while aerosols with high content of organic carbon have large backscatter coefficients (weak absorption). This paper presents a method based on radiative calculations to estimate the black carbon content of biomass burning aerosols from 3b+2a+1d lidar signals. Data is collected at Magurele, Romania, at the cross-road of air masses coming from Ukraine, Russia and Greece, where burning events are frequent during both cold and hot seasons. Aerosols are transported in the free troposphere, generally in the 2-4 km altitude range, and reaches the lidar location after 2-3 days. Optical data are collected between 2011-2012 by a multi-channel Raman lidar and follows the quality assurance program of EARLINET. Radiative calculations are made with libRadTran, an open source radiative model developed by ESA. Validation of the retrievals is made by comparison to a co-located C-ToF Aerosol Mass Spectrometer. Keywords: Lidar, aerosols, biomass burning, radiative model, black carbon Acknowledgment: This work has been supported by grants of the Romanian National Authority for Scientific Research, Programme for Research- Space Technology and Advanced Research - STAR, project no. 39/2012 - SIAFIM, and by Romanian Partnerships in priority areas PNII implemented with MEN-UEFISCDI support, project no. 309/2014 - MOBBE

  3. Submillimeter heterodyne detection of interstellar carbon monoxide at 434 micrometers

    NASA Technical Reports Server (NTRS)

    Fetterman, H. R.; Clifton, B. J.; Peck, D. D.; Tannenwald, P. E.; Koepf, G. A.; Goldsmith, P. F.; Erickson, N. R.; Buhl, D.; Mcavoy, N.

    1981-01-01

    Laser heterodyne observations of submillimeter emissions from carbon monoxide in the Orion molecular cloud are reported. High frequency and spatial resolution observations were made at the NASA Infrared Telescope Facility on Mauna Kea by the use of an optically pumped laser local oscillator and quasi-optical Schottky diode mixer for heterodyne detection of the J = 6 - 5 rotational transition of CO at 434 microns. Spectral analysis of the 434-micron emission indicates that the emitting gas is optically thin and is at a temperature above 180 K. Results thus demonstrate the potential contributions of ground-based high-resolution submillimeter astronomy to the study of active regions in interstellar molecular clouds.

  4. Carbon monoxide transport and actions in blood and tissues.

    PubMed

    Thom, Stephen R

    2011-01-01

    This chapter will discuss the transport of carbon monoxide (CO) from the environment to the tissues of the body and physiological effects on blood-borne cells and perivascular tissues. It will review the physiology of CO exchange between alveolar gas and pulmonary capillary blood, dynamics of hemoglobin transport, the effects of CO on blood elements, and the effects of CO on extravascular tissues at the capillary bed. Effects of CO from exogenous and endogenous sources on the activities of different proteins will be reviewed. Because CO binds competitively to heme-containing proteins its effects depend on CO concentration relative to alternative ligands. Therefore, some discussion is devoted to how nitric oxide and hydrogen sulfide influence CO effects. © 2011 American Physiological Society.

  5. Carbon Monoxide: An Essential Signalling Molecule

    NASA Astrophysics Data System (ADS)

    Mann, Brian E.

    Carbon monoxide (CO), like nitric oxide (NO), is an essential signalling molecule in humans. It is active in the cardiovascular system as a vasodilator. In addition, CO possesses anti-inflammatory, anti-apoptotic and anti-proliferative properties and protects tissues from hypoxia and reperfusion injury. Some of its applications in animal models include suppression of organ graft rejection and safeguarding the heart during reperfusion after cardiopulmonary bypass surgery. CO also suppresses arteriosclerotic lesions following angioplasty, reverses established pulmonary hypertension and mitigates the development of post-operative ileus in the murine small intestine and the development of cerebral malaria in mice as well as graft-induced intimal hyperplasia in pigs. There have been several clinical trials using air-CO mixtures for the treatment of lung-, heart-, kidney- and abdominal-related diseases. This review examines the research involving the development of classes of compounds (with particular emphasis on metal carbonyls) that release CO, which could be used in clinically relevant conditions. The review is drawn not only from published papers in the chemical literature but also from the extensive biological literature and patents on CO-releasing molecules (CO-RMs).

  6. Non-accidental carbon monoxide poisoning from burning charcoal in attempted combined homicide-suicide.

    PubMed

    Lee, A C W; Ou, Y; Lam, S Y; So, K T; Kam, C W

    2002-10-01

    To describe an emerging form of serious child abuse in combined homicide-suicide in Hong Kong. This is a retrospective hospital chart review in a regional hospital in Hong Kong from January to December 2000. Eight children, with a mean age of 7.8 years (range 0.5-11 years), from four families were admitted to hospital because of non-accidental exposure to carbon monoxide when their parents attempted suicide by burning charcoal. A 7-year-old boy died on arrival. His 5.6-year-old sister and another 6-month-old boy had cerebral hypoxia on admission. Hyperbaric oxygen therapy was used in both cases, with rapid improvement, although there were persistent neurological deficits in the girl. The other children in the present study were asymptomatic and none had delayed neurological sequelae. Concomitant use of sedatives was also detected in three of the surviving patients. Non-accidental poisoning with carbon monoxide appears to be a new means of child abuse with potentially serious consequences. Concomitant intoxication with psychotropic drugs is common in such cases. The reason for parents killing their own children under such circumstances was unclear, but a desire to exact revenge on an estranged partner was suggested.

  7. Measuring Carbon Monoxide With TROPOMI: First Results and a Comparison With ECMWF-IFS Analysis Data

    NASA Astrophysics Data System (ADS)

    Borsdorff, T.; Aan de Brugh, J.; Hu, H.; Aben, I.; Hasekamp, O.; Landgraf, J.

    2018-03-01

    The Tropospheric Monitoring Instrument (TROPOMI) was launched onboard of the European Space Agency's (ESA) Sentinel-5P satellite. One of the mission's key products is the total column density of carbon monoxide, inferred from TROPOMI's 2.3 μm measurements. Using the operational processing algorithm, we analyze six subsequent days of measurements during the commissioning phase. The TROPOMI product is compared with CO fields from the European Centre for Medium-Range Weather Forecasts (ECMWF) assimilation system. Globally, a small mean difference between the data sets of 3.2 ± 5.5% with a correlation coefficient of 0.97 is found. The daily global coverage of TROPOMI enables it to capture day-to-day evolution of the atmospheric composition. As an example, we discuss the air pollution event of India in November 2017 with high carbon monoxide (CO) concentrations, which partly dispersed when the CO polluted air was transported north alongside the Himalaya to China. The striking agreement and also regional differences with ECMWF indicate new exciting applications for the TROPOMI CO data product.

  8. Carbon monoxide inhibits omega-oxidation of leukotriene B4 by human polymorphonuclear leukocytes: evidence that catabolism of leukotriene B4 is mediated by a cytochrome P-450 enzyme.

    PubMed

    Shak, S; Goldstein, I M

    1984-09-17

    Carbon monoxide significantly inhibits omega-oxidation of exogenous leukotriene B4 to 20-OH-leukotriene B4 and 20-COOH-leukotriene B4 by unstimulated polymorphonuclear leukocytes as well as omega-oxidation of leukotriene B4 that is generated when cells are stimulated with the calcium ionophore, A23187. Inhibition of omega-oxidation by carbon monoxide is concentration-dependent, completely reversible, and specific. Carbon monoxide does not affect synthesis of leukotriene B4 by stimulated polymorphonuclear leukocytes or other cell functions (i.e., degranulation, superoxide anion generation). These findings suggest that a cytochrome P-450 enzyme in human polymorphonuclear leukocytes is responsible for catabolizing leukotriene B4 by omega-oxidation.

  9. a New Gas Correlation Radiometer for Remote Sounding of Carbon Monoxide

    NASA Astrophysics Data System (ADS)

    Tikhomirov, Alexey; Drummond, James

    Carbon monoxide (CO) is extremely important component of the Earth's atmosphere since it is an indicator of air quality and plays a great role in tropospheric chemistry. Experimental data about CO mixing ratio distribution are necessary to study long range transport of pollutions and are being used along with models in understanding the CO budget. Remote sounding techniques from space are very advantageous in terms of global monitoring of CO. The gas correlation radiometry method has been successfully employed on a number of satellite based instruments for remote sounding of atmospheric gases for several decades. In this report a new concept of gas correlation radiometer for remote sounding of carbon monoxide from space is described. A length modulated cell, used for the first time with the MOPITT instrument, coupled with a static dual detector per channel architecture underlies the optical design of the new sounder. The main goal of the design is to produce an extremely simple and compact system which will in turn lead to a small space instrument. A laboratory prototype of the radiometer has been built in Dalhousie University. Its characteristics are investigated to verify the new concept. The sources of optical imbalance will be discussed as well as the methods for optical imbalance characterization and minimization. The results of the radiometer calibration and laboratory measurements of CO are presented. This work is supported by the Canadian Space Agency, the Canadian Foundation for Innovation, the Atlantic Innovation Fund/Nova Scotia Research Innovation Trust and Dalhousie University.

  10. Mechanism of organic aerosol formation and aging: Role of the precursor carbon skeleton

    NASA Astrophysics Data System (ADS)

    Hunter, J. F.; Carrasquillo, A. J.; Daumit, K. E.; Cross, E. S.; Worsnop, D. R.; Kroll, J. H.

    2012-12-01

    Oxidative aging of organic aerosol consists of a complex set of reactions coupled with gas-particle partitioning processes. Functionalization reactions involve adding oxygen containing functional groups onto a molecule, leading to reduced vapor pressures and promoting aerosol formation. In fragmentation reactions carbon-carbon bonds are broken as oxygen containing functional groups are added, which generally splits the parent molecule into two smaller and more volatile products. The initial structure of an aerosol-forming precursor molecule may influence what chemistry will occur both by changing the branching between fragmentation and functionalization processes as well as changing the effects of those processes. The fate of early generation oxidation products upon further aging is dependent on this initial chemistry, leading to a persistent effect of the precursor carbon skeleton. Aging experiments have been conducted using a high NOx smog chamber based aging technique. Long residence times and modestly elevated OH concentrations lead to typical maximum OH exposure of 3e11 molecule*seconds/cc, approaching several days equivalent exposure to ambient OH concentrations. A broad set of linear, branched and cyclic aliphatic hydrocarbons has been oxidized to determine the effects of carbon skeleton on the relative importance of fragmentation and functionalization and impacts on aerosol formation chemistry. Relative degree of fragmentation and functionalization is constrained by mass spectrometry of both the gas and particle phase. Measurements of the aerosol oxygen content and mass yield are reported, and structural effects on these properties are determined. Degree of unsaturation is hypothesized to have a significant impact on the effect of fragmentation reactions and to promote additional aerosol formation, extended aging and more oxygenated aerosol.

  11. Satellite observations of tropospheric ammonia and carbon monoxide: Global distributions, regional correlations and comparisons to model simulations

    EPA Science Inventory

    Ammonia (NH3) and carbon monoxide (CO) are primary pollutants emitted to the Earth's atmosphere from common as well as distinct sources associated with anthropogenic and natural activities. The seasonal and global distributions and correlations of NH3 and CO from the Tropospheric...

  12. Regional and hemispheric influences on temporal variability in baseline carbon monoxide and ozone over the Northeast US

    EPA Science Inventory

    Interannual variability in baseline carbon monoxide (CO) and ozone (O3), defined as mixing ratios under minimal influence of recent and local emissions, was studied for seven rural sites in the Northeast US over 2001–2010. Annual baseline CO exhibited statistically signific...

  13. Radiative absorption enhancement from coatings on black carbon aerosols.

    PubMed

    Cui, Xinjuan; Wang, Xinfeng; Yang, Lingxiao; Chen, Bing; Chen, Jianmin; Andersson, August; Gustafsson, Örjan

    2016-05-01

    The radiative absorption enhancement of ambient black carbon (BC), by light-refractive coatings of atmospheric aerosols, constitutes a large uncertainty in estimates of climate forcing. The direct measurements of radiative absorption enhancement require the experimentally-removing the coating materials in ambient BC-containing aerosols, which remains a challenge. Here, the absorption enhancement of the BC core by non-absorbing aerosol coatings was quantified using a two-step removal of both inorganic and organic matter coatings of ambient aerosols. The mass absorption cross-section (MAC) of decoated/pure atmospheric BC aerosols of 4.4±0.8m(2)g(-1) was enhanced to 9.6±1.8m(2)g(-1) at 678-nm wavelength for ambiently-coated BC aerosols at a rural Northern China site. The enhancement of MAC (EMAC) rises from 1.4±0.3 in fresh combustion emissions to ~3 for aged ambient China aerosols. The three-week high-intensity campaign observed an average EMAC of 2.25±0.55, and sulfates were primary drivers of the enhanced BC absorption. Copyright © 2016 Elsevier B.V. All rights reserved.

  14. Toxicity of carbon monoxide hydrogen cyanide gas mixtures : exposure concentration, time to incapacitation, carboxyhemoglobin and blood cyanide parameters.

    DOT National Transportation Integrated Search

    1994-04-01

    During aircraft interior fires, carbon monoxide (CO) and hydrogen cyanide (HCN) are produced in sufficient amounts to cause incapacitation and death. Time-to-incapacitation (ti) is a practical parameter for estimating escape time in fire environments...

  15. Unintentional deaths from carbon monoxide in motor vehicle exhaust: West Virginia.

    PubMed Central

    Baron, R C; Backer, R C; Sopher, I M

    1989-01-01

    We investigated the circumstances of unintended carbon monoxide deaths from motor vehicle exhaust. Of 64 episodes involving 82 deaths investigated by the West Virginia Office of the Chief Medical Examiner, 1978-84, 50 occurred outdoors in older vehicles with defective exhaust systems and 14 occurred in enclosed or semi-enclosed home garages. Blood alcohol was detected in 50 (68 per cent) of 74 victims tested; 34 had blood alcohol concentrations greater than or equal to 0.10 g/dl. We suggest increasing public awareness of the hazards of motor vehicle exhaust and enforcing vehicle inspection regulations. PMID:2464951

  16. Light Absorption of Brown Carbon Aerosol in the Pearl River Delta Region of China

    NASA Astrophysics Data System (ADS)

    Huang, X.

    2015-12-01

    X.F. Huang, J.F. Yuan, L.M. Cao, J. Cui, C.N. Huang, Z.J. Lan and L.Y. He Key Laboratory for Urban Habitat Environmental Science and Technology, School of Environment and Energy, Peking University Shenzhen Graduate School, Shenzhen 518055, ChinaCorresponding author. Tel.: +86 755 26032532; fax: +86 755 26035332. E-mail address: huangxf@pku.edu.cn (X. F. Huang). Abstract: The strong spectral dependence of light absorption of brown carbon (BrC) aerosol has been recognized in recent decades. The Absorption Angstrom Exponent (AAE) of ambient aerosol was widely used in previous studies to attribute light absorption of brown carbon at shorter wavelengths, with a theoretical assumption that the AAE of black carbon (BC) aerosol equals to unit. In this study, the AAE method was improved by statistical extrapolation based on ambient measurements in the polluted seasons in typical urban and rural areas in the Pearl River Delta (PRD) region of China. A three-wavelength photoacoustic soot spectrometer (PASS-3) and an aerosol mass spectrometer (AMS) were used to explore the relationship between the ambient measured AAE and the ratio of organic aerosol to BC aerosol, in order to extract the more realistic AAE by pure BC aerosol, which were found to be 0.86, 0.82 and 1.02 at 405nm and 0.70, 0.71, and 0.86 at 532nm in the campaigns of urban-winter, urban-fall, and rural-fall, respectively. Roadway tunnel experiment results further supported the effectiveness of the obtained AAE for pure BC aerosol. In addition, biomass burning experiments proved higher spectral dependence of more-BrC environment and further verified the reliability of the instruments' response. Then, the average light absorption contribution of BrC aerosol was calculated to be 11.7, 6.3 and 12.1% (with total relative uncertainty of 7.5, 6.9 and 10.0%) at 405nm and 10.0, 4.1 and 5.5% (with total relative uncertainty of 6.5, 8.6 and 15.4%) at 532nm of the three campaigns, respectively. These results indicate that the

  17. Carbon monoxide in an extremely metal-poor galaxy.

    PubMed

    Shi, Yong; Wang, Junzhi; Zhang, Zhi-Yu; Gao, Yu; Hao, Cai-Na; Xia, Xiao-Yang; Gu, Qiusheng

    2016-12-09

    Extremely metal-poor galaxies with metallicity below 10% of the solar value in the local universe are the best analogues to investigating the interstellar medium at a quasi-primitive environment in the early universe. In spite of the ongoing formation of stars in these galaxies, the presence of molecular gas (which is known to provide the material reservoir for star formation in galaxies such as our Milky Way) remains unclear. Here we report the detection of carbon monoxide (CO), the primary tracer of molecular gas, in a galaxy with 7% solar metallicity, with additional detections in two galaxies at higher metallicities. Such detections offer direct evidence for the existence of molecular gas in these galaxies that contain few metals. Using archived infrared data, it is shown that the molecular gas mass per CO luminosity at extremely low metallicity is approximately one-thousand times the Milky Way value.

  18. Carbon monoxide in an extremely metal-poor galaxy

    PubMed Central

    Shi, Yong; Wang, Junzhi; Zhang, Zhi-Yu; Gao, Yu; Hao, Cai-Na; Xia, Xiao-Yang; Gu, Qiusheng

    2016-01-01

    Extremely metal-poor galaxies with metallicity below 10% of the solar value in the local universe are the best analogues to investigating the interstellar medium at a quasi-primitive environment in the early universe. In spite of the ongoing formation of stars in these galaxies, the presence of molecular gas (which is known to provide the material reservoir for star formation in galaxies such as our Milky Way) remains unclear. Here we report the detection of carbon monoxide (CO), the primary tracer of molecular gas, in a galaxy with 7% solar metallicity, with additional detections in two galaxies at higher metallicities. Such detections offer direct evidence for the existence of molecular gas in these galaxies that contain few metals. Using archived infrared data, it is shown that the molecular gas mass per CO luminosity at extremely low metallicity is approximately one-thousand times the Milky Way value. PMID:27934880

  19. 40 CFR 60.45Da - Alternative standards for combined nitrogen oxides (NOX) and carbon monoxide (CO).

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 7 2013-07-01 2013-07-01 false Alternative standards for combined nitrogen oxides (NOX) and carbon monoxide (CO). 60.45Da Section 60.45Da Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for...

  20. 40 CFR 60.45Da - Alternative standards for combined nitrogen oxides (NOX) and carbon monoxide (CO).

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 7 2012-07-01 2012-07-01 false Alternative standards for combined nitrogen oxides (NOX) and carbon monoxide (CO). 60.45Da Section 60.45Da Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for...

  1. 40 CFR 60.45Da - Alternative standards for combined nitrogen oxides (NOX) and carbon monoxide (CO).

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 7 2014-07-01 2014-07-01 false Alternative standards for combined nitrogen oxides (NOX) and carbon monoxide (CO). 60.45Da Section 60.45Da Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for...

  2. Contribution of Black Carbon Aerosol to Drying of the Mediterranean

    NASA Astrophysics Data System (ADS)

    Tang, T.; Shindell, D. T.; Samset, B. H.; Boucher, O.; Forster, P.; Hodnebrog, Ø.; Myhre, G.; Sillmann, J.; Voulgarakis, A.; Andrews, T.; Faluvegi, G.; Fläschner, D.; Iverson, T.; Kasoar, M.; Kharin, V. V.; Kirkevag, A.; Lamarque, J. F.; Olivié, D.; Richardson, T.; Stjern, C.; Takemura, T.; Zwiers, F. W.

    2017-12-01

    Atmospheric aerosols affect cloud properties, radiative balance and thus, the hydrological cycle. Many studies have reported that precipitation has decreased in the Mediterranean since the mid-20th century, and investigated possible mechanisms. So far, however, the effects of aerosol forcing on Mediterranean precipitation remain largely unknown. Here we compare observed Mediterranean precipitation trends during 1951-2010 with responses to individual forcing in a set of state-of-the-art global climate models. Our analyses suggest that nearly one-third (30%) of the observed precipitation decrease may be attributable to black carbon forcing. The remainder is most strongly linked to forcing of well-mixed greenhouse gases (WMGHGs), with scattering sulfate aerosols having negligible impacts. Black carbon caused an enhanced positive North Atlantic Oscillation (NAO)/Arctic Oscillation (AO)-like sea level pressure (SLP) pattern, characterized by higher SLP at mid-latitudes and lower SLP at high-latitudes. This SLP change diverted the jet stream and storm tracks further northward, reducing precipitation in the Mediterranean while increasing precipitation in Northern Europe. The results from this study suggest that future black carbon emissions may significantly affect regional water resources, agricultural practices, ecosystems, and economy in the Mediterranean region.

  3. Source contributions to black carbon mass fractions in aerosol particles over the northwestern Pacific

    NASA Astrophysics Data System (ADS)

    Koga, Seizi; Maeda, Takahisa; Kaneyasu, Naoki

    Aerosol particle number size distributions above 0.3 μm in diameter and black carbon mass concentrations in aerosols were observed on Chichi-jima of the Ogasawara Islands in the northwestern Pacific from January 2000 to December 2002. Chichi-jima is suitable to observe polluted air masses from East Asia in winter and clean air masses over the western North Pacific in summer. In winter, aerosols over Chichi-jima were strongly affected by anthropogenic emissions in East Asia. The form of energy consumption in East Asia varies in various regions. Hence, each source region is expected to be characterized by an individual black carbon mass fraction. A three-dimensional Eulerian transport model was used to estimate contribution rates to air pollutants from each source region in East Asia. Because the Miyake-jima eruption began at the end of June 2000, the influence of smokes from Miyake-jima was also considered in the model calculation. The results of model calculations represent what must be noticed about smokes from volcanoes including Miyake-jima to interpret temporal variations of sulfur compounds over the northwestern Pacific. To evaluate black carbon mass fractions in anthropogenic aerosols as a function of source region, the relationships between the volume concentration of aerosol particles and the black carbon mass concentration in the winter were classified under each source region in East Asia. Consequently, the black carbon mass fractions in aerosols from China, Japan and the Korean Peninsula, and other regions were estimated to be 9-13%, 5-7%, and 4-5%, respectively.

  4. Chemical Feedback From Decreasing Carbon Monoxide Emissions

    NASA Astrophysics Data System (ADS)

    Gaubert, B.; Worden, H. M.; Arellano, A. F. J.; Emmons, L. K.; Tilmes, S.; Barré, J.; Martinez Alonso, S.; Vitt, F.; Anderson, J. L.; Alkemade, F.; Houweling, S.; Edwards, D. P.

    2017-10-01

    Understanding changes in the burden and growth rate of atmospheric methane (CH4) has been the focus of several recent studies but still lacks scientific consensus. Here we investigate the role of decreasing anthropogenic carbon monoxide (CO) emissions since 2002 on hydroxyl radical (OH) sinks and tropospheric CH4 loss. We quantify this impact by contrasting two model simulations for 2002-2013: (1) a Measurement of the Pollution in the Troposphere (MOPITT) CO reanalysis and (2) a Control-Run without CO assimilation. These simulations are performed with the Community Atmosphere Model with Chemistry of the Community Earth System Model fully coupled chemistry climate model with prescribed CH4 surface concentrations. The assimilation of MOPITT observations constrains the global CO burden, which significantly decreased over this period by 20%. We find that this decrease results to (a) increase in CO chemical production, (b) higher CH4 oxidation by OH, and (c) 8% shorter CH4 lifetime. We elucidate this coupling by a surrogate mechanism for CO-OH-CH4 that is quantified from the full chemistry simulations.

  5. Lethal carbon monoxide toxicity in a concrete shower unit.

    PubMed

    Heath, Karen; Byard, Roger W

    2018-05-23

    A 47-year-old previously-well woman was found dead on the floor of a shower cubicle on a property in rural South Australia. The impression of the attending doctor and police was of collapse due to natural disease. Although there was significant stenosing coronary artery atherosclerosis found at autopsy, cherry pink discoloration of tissues prompted measurement of the blood carboxyhemoglobin level which was found to be 55%. The source of the gas was a poorly-maintained hot water heater that was mounted on the inside wall of the shower. Construction of the shower using an impermeable concrete rain water tank had caused gas accumulation when the water heater malfunctioned. Had lethal carbon monoxide exposure not been identified others using the same shower unit would also have been at risk.

  6. Monitoring of endogenous carbon monoxide dynamics in human breath by tunable diode laser

    NASA Astrophysics Data System (ADS)

    Stepanov, Eugene V.; Daraselia, Mikhail V.; Zyrianov, Pavel V.; Shulagin, Yurii A.; Skrupskii, Vladimir A.

    1996-01-01

    High sensitive CO gas analyzer based on tunable diode laser (TDL) was used as a real time monitor of endogenous carbon monoxide in a set of breath physiology experiments. The measurements of the CO content dynamics in exhaled air with 10 ppb sensitivity were attended with detection of carbon dioxide and O2 in breath, lung ventilation parameters, heart rate and blood analysis using conventional techniques. Temporal variations of endogenous CO in human breath caused by hyperoxia, hypoxia, hyperventilation and sport loading were first studied in real time. Scattering of the CO variation time constants was observed for different tested persons. Possible reasons for this scattering related with the organisms' physiology peculiarities are discussed.

  7. Assessment of the Aerosol Generation and Toxicity of Carbon Nanotubes

    PubMed Central

    O’Shaughnessy, Patrick T.; Adamcakova-Dodd, Andrea; Altmaier, Ralph; Thorne, Peter S.

    2014-01-01

    Current interest in the pulmonary toxicity of carbon nanotubes (CNTs) has resulted in a need for an aerosol generation system that is capable of consistently producing a CNT aerosol at a desired concentration level. This two-part study was designed to: (1) assess the properties of a commercially-available aerosol generator when producing an aerosol from a purchased powder supply of double-walled carbon nanotubes (DWCNTs); and (2) assess the pulmonary sub-acute toxicity of DWCNTs in a murine model during a 5-day (4 h/day) whole-body exposure. The aerosol generator, consisting of a novel dustfeed mechanism and venturi ejector was determined to be capable of producing a DWCNT consistently over a 4 h exposure period at an average level of 10.8 mg/m3. The count median diameter was 121 nm with a geometric standard deviation of 2.04. The estimated deposited dose was 32 µg/mouse. The total number of cells in bronchoalveolar lavage (BAL) fluid was significantly (p < 0.01) increased in exposed mice compared to controls. Similarly, macrophages in BAL fluid were significantly elevated in exposed mice, but not neutrophils. All animals exposed to CNT and euthanized immediately after exposure had changes in the lung tissues showing acute inflammation and injury; however these pathological changes resolved two weeks after the exposure. PMID:28344231

  8. Assessment of the Aerosol Generation and Toxicity of Carbon Nanotubes.

    PubMed

    O'Shaughnessy, Patrick T; Adamcakova-Dodd, Andrea; Altmaier, Ralph; Thorne, Peter S

    2014-06-12

    Current interest in the pulmonary toxicity of carbon nanotubes (CNTs) has resulted in a need for an aerosol generation system that is capable of consistently producing a CNT aerosol at a desired concentration level. This two-part study was designed to: (1) assess the properties of a commercially-available aerosol generator when producing an aerosol from a purchased powder supply of double-walled carbon nanotubes (DWCNTs); and (2) assess the pulmonary sub-acute toxicity of DWCNTs in a murine model during a 5-day (4 h/day) whole-body exposure. The aerosol generator, consisting of a novel dustfeed mechanism and venturi ejector was determined to be capable of producing a DWCNT consistently over a 4 h exposure period at an average level of 10.8 mg/m³. The count median diameter was 121 nm with a geometric standard deviation of 2.04. The estimated deposited dose was 32 µg/mouse. The total number of cells in bronchoalveolar lavage (BAL) fluid was significantly ( p < 0.01) increased in exposed mice compared to controls. Similarly, macrophages in BAL fluid were significantly elevated in exposed mice, but not neutrophils. All animals exposed to CNT and euthanized immediately after exposure had changes in the lung tissues showing acute inflammation and injury; however these pathological changes resolved two weeks after the exposure.

  9. Diiridium Bimetallic Complexes Function as a Redox Switch To Directly Split Carbonate into Carbon Monoxide and Oxygen.

    PubMed

    Chen, Tsun-Ren; Wu, Fang-Siou; Lee, Hsiu-Pen; Chen, Kelvin H-C

    2016-03-23

    A pair of diiridium bimetallic complexes exhibit a special type of oxidation-reduction reaction that could directly split carbonate into carbon monoxide and molecular oxygen via a low-energy pathway needing no sacrificial reagent. One of the bimetallic complexes, Ir(III)(μ-Cl)2Ir(III), can catch carbonato group from carbonate and reduce it to CO. The second complex, the rare bimetallic complex Ir(IV)(μ-oxo)2Ir(IV), can react with chlorine to release O2 by the oxidation of oxygen ions with synergistic oxidative effect of iridium ions and chlorine atoms. The activation energy needed for the key reaction is quite low (∼20 kJ/mol), which is far less than the dissociation energy of the C═O bond in CO2 (∼750 kJ/mol). These diiridium bimetallic complexes could be applied as a redox switch to split carbonate or combined with well-known processes in the chemical industry to build up a catalytic system to directly split CO2 into CO and O2.

  10. The validation of the Yonsei CArbon Retrieval algorithm with improved aerosol information using GOSAT measurements

    NASA Astrophysics Data System (ADS)

    Jung, Yeonjin; Kim, Jhoon; Kim, Woogyung; Boesch, Hartmut; Goo, Tae-Young; Cho, Chunho

    2017-04-01

    Although several CO2 retrieval algorithms have been developed to improve our understanding about carbon cycle, limitations in spatial coverage and uncertainties due to aerosols and thin cirrus clouds are still remained as a problem for monitoring CO2 concentration globally. Based on an optimal estimation method, the Yonsei CArbon Retrieval (YCAR) algorithm was developed to retrieve the column-averaged dry-air mole fraction of carbon dioxide (XCO2) using the Greenhouse Gases Observing SATellite (GOSAT) measurements with optimized a priori CO2 profiles and aerosol models over East Asia. In previous studies, the aerosol optical properties (AOP) are the most important factors in CO2 retrievals since AOPs are assumed as fixed parameters during retrieval process, resulting in significant XCO2 retrieval error up to 2.5 ppm. In this study, to reduce these errors caused by inaccurate aerosol optical information, the YCAR algorithm improved with taking into account aerosol optical properties as well as aerosol vertical distribution simultaneously. The CO2 retrievals with two difference aerosol approaches have been analyzed using the GOSAT spectra and have been evaluated throughout the comparison with collocated ground-based observations at several Total Carbon Column Observing Network (TCCON) sites. The improved YCAR algorithm has biases of 0.59±0.48 ppm and 2.16±0.87 ppm at Saga and Tsukuba sites, respectively, with smaller biases and higher correlation coefficients compared to the GOSAT operational algorithm. In addition, the XCO2 retrievals will be validated at other TCCON sites and error analysis will be evaluated. These results reveal that considering better aerosol information can improve the accuracy of CO2 retrieval algorithm and provide more useful XCO2 information with reduced uncertainties. This study would be expected to provide useful information in estimating carbon sources and sinks.

  11. Detection of carbon monoxide and water absorption lines in an exoplanet atmosphere.

    PubMed

    Konopacky, Quinn M; Barman, Travis S; Macintosh, Bruce A; Marois, Christian

    2013-03-22

    Determining the atmospheric structure and chemical composition of an exoplanet remains a formidable goal. Fortunately, advancements in the study of exoplanets and their atmospheres have come in the form of direct imaging--spatially resolving the planet from its parent star--which enables high-resolution spectroscopy of self-luminous planets in jovian-like orbits. Here, we present a spectrum with numerous, well-resolved molecular lines from both water and carbon monoxide from a massive planet orbiting less than 40 astronomical units from the star HR 8799. These data reveal the planet's chemical composition, atmospheric structure, and surface gravity, confirming that it is indeed a young planet. The spectral lines suggest an atmospheric carbon-to-oxygen ratio that is greater than that of the host star, providing hints about the planet's formation.

  12. Vehicle occupant exposure to carbon monoxide.

    PubMed

    Koushki, P A; al-Dhowalia, K H; Niaizi, S A

    1992-12-01

    This paper focuses on the auto commuting micro-environment and presents typical carbon monoxide (CO) concentrations to which auto commuters in central Riyadh, Saudi Arabia were exposed. Two test vehicles traveling over four main arterial roadways were monitored for inside and outside CO levels during eighty peak and off-peak hours extending over an eight-month period. The relative importance of several variables which explained the variability in CO concentrations inside autos was also assessed. It was found that during peak hours auto commuters were exposed to mean CO levels that ranged from 30 to 40 ppm over trips that typically took between 25 to 40 minutes. The mean ratio of inside to outside CO levels was 0.84. Results of variance component analyses indicated that the most important variables affecting CO concentrations inside autos were, in addition to the smoking of vehicle occupants, traffic volume, vehicle speed, period of day and wind velocity. An increase in traffic volume from 1,000 to 5,000 vehicles per hour (vph) increased mean CO level exposure by 71 percent. An increase in vehicle speed from 14 to 55 km/h reduced mean CO exposure by 36 percent. The number of traffic interruptions had a moderate effect on mean concentrations of CO inside vehicles.

  13. Carbon Monoxide Hydrogenation on Ice Surfaces.

    PubMed

    Kuwahata, Kazuaki; Ohno, Kaoru

    2018-03-14

    We have performed density functional calculations to investigate the carbon monoxide hydrogenation reaction (H+CO→HCO), which is important in interstellar clouds. We found that the activation energy of the reaction on amorphous ice is lower than that on crystalline ice. In the course of this study, we demonstrated that it is roughly possible to use the excitation energy of the reactant molecule (CO) in place of the activation energy. This relationship holds also for small water clusters at the CCSD level of calculation and the two-layer-level ONIOM (CCSD : X3LYP) calculation. Generally, since it is computationally demanding to estimate activation energies of chemical reactions in a circumstance of many water molecules, this relationship enables one to determine the activation energy of this reaction on ice surfaces from the knowledge of the excitation energy of CO only. Incorporating quantum-tunneling effects, we discuss the reaction rate on ice surfaces. Our estimate that the reaction rate on amorphous ice is almost twice as large as that on crystalline ice is qualitatively consistent with the experimental evidence reported by Hidaka et al. [Chem. Phys. Lett., 2008, 456, 36.]. © 2018 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. Comparison of measurement capability with 100 μmol/mol of carbon monoxide in nitrogen

    NASA Astrophysics Data System (ADS)

    Lee, Jeongsoon; Lee, JinBok; Lim, Jeongsik; Tarhan, Tanıl; Liu, Hsin-Wang; Aggarwal, Shankar G.

    2018-01-01

    Carbon monoxide (CO) in nitrogen was one of the first types of gas mixtures used in an international key comparison. The comparison dates back to 1998 (CCQMK1a) [1]. Since then, many National Metrology Institutes (NMIs) have developed calibration and measurement capabilities (CMCs) for these mixtures. Recently, NMIs in the APMP region have actively participated in international comparisons to provide domestic services. At the 2013 APMP meeting, several NMIs requested a CO comparison to establish CO/N2 certification for industrial applications, which was to be coordinated by KRISS. Consequently, this comparison provides an opportunity for APMP regional NMIs to develop CO/N2 CMC claims. The goal of this supplementary comparison is to support CMC claim for carbon monoxide in the N2 range of 50–2000 μmol/mol. An extended range may be supported as described in the GAWG strategy for comparisons and CMC claims. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  15. Carbon-monoxide poisoning in young drug addicts due to indoor use of a gasoline-powered generator.

    PubMed

    Marc, B; Bouchez-Buvry, A; Wepierre, J L; Boniol, L; Vaquero, P; Garnier, M

    2001-06-01

    We report six fatal cases of unintentional carbon-monoxide poisoning which occurred in a house occupied by young people. The source of carbon monoxide was a gasoline-powered generator. For all victims, an external body examination was carried out and blood and urine samples collected. Blood carboxyhaemoglobin (COHb) was performed using an automated visible spectrophotometric analysis. Blood-alcohol level quantification was performed using gas chromatography and drug screening in urine was performed by a one-step manual qualitative immunochromatography (Syva Rapid test, Behring Diagnostics Inc.) for benzoylecgonine (the main metabolite of cocaine in urine), morphine, 11-nor-Delta(9)-THC-9-COOH (cannabinoids) and d-methamphetamine. In all victims the COHb value was as high or higher than 65%. No alcohol was found in blood samples, but urine samples were positive for methamphetamine, cocaine and cannabis in five cases and for opiates in one case. In four victims, the urine sample was positive for at least three drugs. The availability and accuracy of rapid toxicological screening is an important tool for the medical examiner at the immediate scene of a clinical forensic examination.

  16. Carbon content of common airborne fungal species and fungal contribution to aerosol organic carbon in a subtropical city

    NASA Astrophysics Data System (ADS)

    Cheng, Jessica Y. W.; Chan, Chak K.; Lee, C.-T.; Lau, Arthur P. S.

    Interest in the role and contribution of fungi to atmospheric aerosols and processes grows in the past decade. Substantial data or information such as fungal mass or carbon loading to ambient aerosols is however still lacking. This study aimed to quantify the specific organic carbon content (OC per spore) of eleven fungal species commonly found airborne in the subtropics, and estimated their contribution to organic carbon in aerosols. The specific OC contents showed a size-dependent relationship ( r = 0.64, p < 0.05) and ranged from 3.6 to 201.0 pg carbon per spore or yeast cell, giving an average of 6.0 pg carbon per spore (RSD 51%) for spore or cell size less than 10 μm. In accounting for natural variations in the composition and abundance of fungal population, weighted-average carbon content for field samples was adopted using the laboratory determined specific OC values. An average of 5.97 pg carbon per spore (RSD 3.8%) was enumerated from 28 field samples collected at the university campus. The mean fungal OC concentration was 3.7, 6.0 and 9.7 ng m -3 in PM 2.5, PM 2.5-10 and PM 10, respectively. These corresponded to 0.1%, 1.2% and 0.2% of the total OC in PM 2.5, PM 2.5-10 and PM 10, respectively. In the study period, rain provided periods with low total OC but high fungal prevalence and fungi contributed 7-32% OC in PM 2.5-10 or 2.4-7.1% OC in PM 10. More extensive studies are deserved to better understand the spatial-, temporal- and episodic dependency on the fungal OC contribution to the atmospheric aerosols.

  17. Convective Influence and Transport Pathways Controlling the Tropical Distribution of Carbon Monoxide at 100 Hpa

    NASA Technical Reports Server (NTRS)

    Jensen, Eric; Bergman, John; Pfister, Leonard; Ueyama, Rei; Kinnison, Doug

    2014-01-01

    Trajectory calculations with convective influence diagnosed from geostationary-satellite cloud measurements are used to evaluate the relative importance of different Tropical Tropopause Layer (TTL) transport pathways for establishing the distribution of carbon monoxide (CO) at 100 hPa as observed by the Microwave Limb Sounder (MLS) on board the Aura satellite. Carbon monoxide is a useful tracer for investigating TTL transport and convective influence because the CO lifetime is comparable to the time require for slow ascent through the TTL (a couple of months). Offline calculations of TTL radiative heating are used to determine the vertical motion field. The simple trajectory model does a reasonable job of reproducing the MLS CO distributions during Boreal wintertime and summertime. The broad maximum in CO concentration over the Pacific is primarily a result of the strong radiative heating (indicating upward vertical motion) associated with the abundant TTL cirrus in this region. Sensitivity tests indicate that the distinct CO maximum in the Asian monsoon anticyclone is strongly impacted by extreme convective systems with detrainment of polluted air above 360 K potential temperature. The relative importance of different CO source regions will also be discussed.

  18. Carbon monoxide and nitrogen dioxide levels in an indoor ice skating rink with mitigation methods

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lee, K.; Yanagisawa, Y.; Spengler, J.D.

    1993-05-01

    An indoor ice skating rink is an enclosed space with intermittent air pollutant emissions from fuel-powered ice-resurfacing equipment, such as a resurfacer and an edger. Exhaust gases discharged from the resurfacing equipment actually include significant quantities of carbon monoxide (CO) and nitrogen dioxide (NO[sub 2]) which may induced adverse health effects. Carbon monoxide exposures in ice skating rinks resulting from malfunctioning ice resurfacing equipment were first reported more than twenty years ago. Attempts to reduce emissions of CO and NO[sub 2] form resurfacing equipment, such as the extended exhaust pipe, operation of the air recirculation system or reduced resurfacer operation,more » appeared not to be effective for maintaining the air pollutant concentrations below guidelines. Even though improved indoor air quality was obtained by the combination of the full operation of the air exhaust system and the reduced number of resurfacer operations in this investigation, these methods may be impractical for most skating rinks. Replacement of the fuel-powered resurfacer with a battery operated resurfacer is recommended. If replacement is not feasible, then increasing the air ventilation rate is recommended as a second choice. 10 refs., 1 fig., 1 tab.« less

  19. Increase in upper tropospheric and lower stratospheric aerosol levels and its potential connection with Asian pollution.

    PubMed

    Vernier, J-P; Fairlie, T D; Natarajan, M; Wienhold, F G; Bian, J; Martinsson, B G; Crumeyrolle, S; Thomason, L W; Bedka, K M

    2015-02-27

    Satellite observations have shown that the Asian Summer Monsoon strongly influences the upper troposphere and lower stratosphere (UTLS) aerosol morphology through its role in the formation of the Asian Tropopause Aerosol Layer (ATAL). Stratospheric Aerosol and Gas Experiment II solar occultation and Cloud-Aerosol Lidar and Infrared Pathfinder Satellite Observation (CALIPSO) lidar observations show that summertime UTLS Aerosol Optical Depth (AOD) between 13 and 18 km over Asia has increased by three times since the late 1990s. Here we present the first in situ balloon measurements of aerosol backscatter in the UTLS from Western China, which confirm high aerosol levels observed by CALIPSO since 2006. Aircraft in situ measurements suggest that aerosols at lower altitudes of the ATAL are largely composed of carbonaceous and sulfate materials (carbon/sulfur elemental ratio ranging from 2 to 10). Back trajectory analysis from Cloud-Aerosol Lidar with Orthogonal Polarization observations indicates that deep convection over the Indian subcontinent supplies the ATAL through the transport of pollution into the UTLS. Time series of deep convection occurrence, carbon monoxide, aerosol, temperature, and relative humidity suggest that secondary aerosol formation and growth in a cold, moist convective environment could play an important role in the formation of ATAL. Finally, radiative calculations show that the ATAL layer has exerted a short-term regional forcing at the top of the atmosphere of -0.1 W/m 2 in the past 18 years. Increase of summertime upper tropospheric aerosol levels over Asia since the 1990s Upper tropospheric enhancement also observed by in situ backscatter measurements Significant regional radiative forcing of -0.1 W/m 2 .

  20. Formation of carbon allotrope aerosol by colliding plasmas in an inertial fusion reactor

    NASA Astrophysics Data System (ADS)

    Hirooka, Y.; Sato, H.; Ishihara, K.; Yabuuchi, T.; Tanaka, K. A.

    2014-02-01

    Along with repeated implosions, the interior of an inertial fusion target chamber is exposed to short pulses of high-energy x-ray, unburned DT-fuel particles, He-ash and pellet debris. As a result, chamber wall materials are subjected to ablation, emitting particles in the plasma state. Ablated particles will either be re-deposited elsewhere or collide with each other, perhaps in the centre-of-symmetry region of the chamber volume. Colliding ablation plasma particles can lead to the formation of clusters to grow into aerosol, possibly floating thereafter, which can deteriorate the subsequent implosion performance via laser scattering, etc. In a laboratory-scale YAG laser setup, the formation of nano-scale aerosol has been demonstrated in vacuum at irradiation power densities of the orders of 108-10 W cm-2 at 10 Hz, each 6 ns long, simulating the high-repetition rate inertial fusion reactor situation. Interestingly, carbon aerosol formation has been observed in the form of fullerene onion, nano- and micro-tubes when laser-ablated plasma plumes of carbon collide with each other. In contrast, colliding plasma plumes of metals tend to generate aerosol in the form of droplets under identical laser irradiation conditions. An atomic and molecular reaction model is proposed to interpret the process of carbon allotrope aerosol formation.

  1. Organic carbon content of marine aerosols collected on Bermuda

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hoffman, E.J.; Duce, R.A.

    1974-01-01

    The concentration of total organic carbon in marine aerosols collected from a 20-m tower on the Southwest Coast of Bermuda ranged from 0.15 to 0.47 microgram/M/sup 3/ STP under onshore wind conditions. The mass of the organic carbon ranged from 1 to 19% of the mass of sea salt in the particles in Bermuda, and the percentage decreased with increasing salt content.

  2. Identifying Aerosol Type/Mixture from Aerosol Absorption Properties Using AERONET

    NASA Technical Reports Server (NTRS)

    Giles, D. M.; Holben, B. N.; Eck, T. F.; Sinyuk, A.; Dickerson, R. R.; Thompson, A. M.; Slutsker, I.; Li, Z.; Tripathi, S. N.; Singh, R. P.; hide

    2010-01-01

    Aerosols are generated in the atmosphere through anthropogenic and natural mechanisms. These sources have signatures in the aerosol optical and microphysical properties that can be used to identify the aerosol type/mixture. Spectral aerosol absorption information (absorption Angstrom exponent; AAE) used in conjunction with the particle size parameterization (extinction Angstrom exponent; EAE) can only identify the dominant absorbing aerosol type in the sample volume (e.g., black carbon vs. iron oxides in dust). This AAE/EAE relationship can be expanded to also identify non-absorbing aerosol types/mixtures by applying an absorption weighting. This new relationship provides improved aerosol type distinction when the magnitude of absorption is not equal (e.g, black carbon vs. sulfates). The Aerosol Robotic Network (AERONET) data provide spectral aerosol optical depth and single scattering albedo - key parameters used to determine EAE and AAE. The proposed aerosol type/mixture relationship is demonstrated using the long-term data archive acquired at AERONET sites within various source regions. The preliminary analysis has found that dust, sulfate, organic carbon, and black carbon aerosol types/mixtures can be determined from this AAE/EAE relationship when applying the absorption weighting for each available wavelength (Le., 440, 675, 870nm). Large, non-spherical dust particles absorb in the shorter wavelengths and the application of 440nm wavelength absorption weighting produced the best particle type definition. Sulfate particles scatter light efficiently and organic carbon particles are small near the source and aggregate over time to form larger less absorbing particles. Both sulfates and organic carbon showed generally better definition using the 870nm wavelength absorption weighting. Black carbon generation results from varying combustion rates from a number of sources including industrial processes and biomass burning. Cases with primarily black carbon showed

  3. Iron Catalyst Chemistry in High Pressure Carbon Monoxide Nanotube Reactor

    NASA Technical Reports Server (NTRS)

    Scott, Carl D.; Povitsky, Alexander; Dateo, Christopher; Gokcen, Tahir; Smalley, Richard E.

    2001-01-01

    The high-pressure carbon monoxide (HiPco) technique for producing single wall carbon nanotubes (SWNT) is analyzed using a chemical reaction model coupled with properties calculated along streamlines. Streamline properties for mixing jets are calculated by the FLUENT code using the k-e turbulent model for pure carbon monixide. The HiPco process introduces cold iron pentacarbonyl diluted in CO, or alternatively nitrogen, at high pressure, ca. 30 atmospheres into a conical mixing zone. Hot CO is also introduced via three jets at angles with respect to the axis of the reactor. Hot CO decomposes the Fe(CO)5 to release atomic Fe. Cluster reaction rates are from Krestinin, et aI., based on shock tube measurements. Another model is from classical cluster theory given by Girshick's team. The calculations are performed on streamlines that assume that a cold mixture of Fe(CO)5 in CO is introduced along the reactor axis. Then iron forms clusters that catalyze the formation of SWNTs from the Boudouard reaction on Fe-containing clusters by reaction with CO. To simulate the chemical process along streamlines that were calculated by the fluid dynamics code FLUENT, a time history of temperature and dilution are determined along streamlines. Alternative catalyst injection schemes are also evaluated.

  4. Carbon monoxide mixing ratio inference from gas filter radiometer data

    NASA Technical Reports Server (NTRS)

    Wallio, H. A.; Reichle, H. G., Jr.; Casas, J. C.; Saylor, M. S.; Gormsen, B. B.

    1983-01-01

    A new algorithm has been developed which permits, for the first time, real time data reduction of nadir measurements taken with a gas filter correlation radiometer to determine tropospheric carbon monoxide concentrations. The algorithm significantly reduces the complexity of the equations to be solved while providing accuracy comparable to line-by-line calculations. The method is based on a regression analysis technique using a truncated power series representation of the primary instrument output signals to infer directly a weighted average of trace gas concentration. The results produced by a microcomputer-based implementation of this technique are compared with those produced by the more rigorous line-by-line methods. This algorithm has been used in the reduction of Measurement of Air Pollution from Satellites, Shuttle, and aircraft data.

  5. Wet Removal of Organic and Black Carbon Aerosols

    NASA Astrophysics Data System (ADS)

    Torres, A.; Bond, T. C.; Lehmann, C.

    2012-12-01

    Organic carbon (OC) and black carbon (BC) aerosols derived from the combustion of fossil fuels and biomass are significant atmospheric pollutants that alter the Earth's radiation balance and affect human health. Carbonaceous aerosol lifetime and extent of its effects are mainly controlled by its wet removal, especially by rain. Limited work has been done to measure both BC and OC from rain events even though these aerosols are co-emitted and exist together in the atmosphere. The choices of analytical techniques for measuring OC and BC in water are limited, and researchers often employ the same techniques used for measuring atmospheric carbon particles. There is no agreement in the methods employed for monitoring carbon concentration in precipitation. As part of the method development, the Single Particle Soot Photometer (SP2), Thermal-Optical Analysis (TOA), Ultraviolet/Visible (UV/VIS) Spectrophotometer, and the Total Organic Carbon (TOC) Analyzer were evaluated for measuring BC suspended in water, water insoluble OC (WIOC) and dissolved OC (DOC). The study also monitored the concentration of BC, WIOC, and DOC in rainwater collected at Bondville (Illinois) for 18 months. Results indicated that 34% (±3%) of the BC mass was lost in the SP2 analysis, most probably during the nebulization process. Filtration required for TOA also had large losses (>75%) because quartz fiber filters were ineffective for capturing BC particles from water. Addition of NH4H2PO4 as a coagulant improved (>95%) the capture efficiency of the filters. UV/VIS spectrophotometry had good linearity, but the sensitivity for detecting BC particles (±20 μg/L) suspended in water was inadequate. TOC analysis was a robust technique for measuring both DOC and total carbon (BC + OC). The chosen techniques were TOC analysis for DOC, and TOA with an optimized filtration procedure for BC and WIOC. The mean concentrations in rainwater were 8.72 (±9.84) μg/L of BC, 88.97 (±62.64) μg/L of WIOC, and 1

  6. Multi-walled carbon nanotubes: sampling criteria and aerosol characterization

    PubMed Central

    Chen, Bean T.; Schwegler-Berry, Diane; McKinney, Walter; Stone, Samuel; Cumpston, Jared L.; Friend, Sherri; Porter, Dale W.; Castranova, Vincent; Frazer, David G.

    2015-01-01

    This study intends to develop protocols for sampling and characterizing multi-walled carbon nanotube (MWCNT) aerosols in workplaces or during inhalation studies. Manufactured dry powder containing MWCNT’s, combined with soot and metal catalysts, form complex morphologies and diverse shapes. The aerosols, examined in this study, were produced using an acoustical generator. Representative samples were collected from an exposure chamber using filters and a cascade impactor for microscopic and gravimetric analyses. Results from filters showed that a density of 0.008–0.10 particles per µm2 filter surface provided adequate samples for particle counting and sizing. Microscopic counting indicated that MWCNT’s, resuspended at a concentration of 10 mg/m3, contained 2.7 × 104 particles/cm3. Each particle structure contained an average of 18 nanotubes, resulting in a total of 4.9 × 105 nanotubes/cm3. In addition, fibrous particles within the aerosol had a count median length of 3.04 µm and a width of 100.3 nm, while the isometric particles had a count median diameter of 0.90 µm. A combination of impactor and microscopic measurements established that the mass median aerodynamic diameter of the mixture was 1.5 µm. It was also determined that the mean effective density of well-defined isometric particles was between 0.71 and 0.88 g/cm3, and the mean shape factor of individual nanotubes was between 1.94 and 2.71. The information obtained from this study can be used for designing animal inhalation exposure studies and adopted as guidance for sampling and characterizing MWCNT aerosols in workplaces. The measurement scheme should be relevant for any carbon nanotube aerosol. PMID:23033994

  7. Exhaled carbon monoxide: a non-invasive biomarker of short-term exposure to outdoor air pollution.

    PubMed

    Lawin, Herve; Ayi Fanou, Lucie; Hinson, Vikkey; Wanjiku, Jacqueline; Ukwaja, N Kingsley; Gordon, Stephen B; Fayomi, Benjamin; Balmes, John R; Houngbegnon, Parfait; Avokpaho, Euripide; Sanni, Ambaliou

    2017-04-17

    In urban settings of Africa with rapidly increasing population, traffic-related air pollution is a major contributor to outdoor air pollution (OAP). Although OAP has been identified as a leading cause of global morbidity and mortality, there is however, lack of a simple biomarker to assess levels of exposure to OAP in resource-poor settings. This study evaluated the role of exhaled carbon monoxide (exhCO) as a potential biomarker of exposure to ambient carbon monoxide (ambCO) from OAP. This was a descriptive study conducted among male commercial motorcycle riders in Cotonou - the economic capital of Benin. The participants' AmbCO was measured using a portable carbon monoxide (CO) data logger for 8 h during the period of their shift. ExhCO was measured just before and immediately after their shift (8-h) Participants were asked not to cook or to smoke during the day of the measurements. Linear regression analysis was used to assess the association between ambCO and exhCO for the last 2, 4 and 6 h of their shift. Of 170 participants who completed the study, their mean ± SD age was 42.2 ± 8.4 years, and their mean ± SD daily income was 7.3 ± 2.7$. Also, 95% of the participants' used solid fuels for cooking and only 2% had ever smoked. Average exhCO increased by 5.1 ppm at the end of the shift (p = 0.004). Post-shift exhCO was significantly associated to ambCO, this association was strongest for the last 2 h of OAP exposure before exhCO measurement (β = 0.34, p < 0.001). ExhCO level was associated with recent exposure to ambCO from OAP with measurable increase after 8 h of exposure. These findings suggest that ExhCO may be a potential biomarker of short-term exposure to OAP.

  8. Technical note: Aerosol light absorption measurements with a carbon analyser - Calibration and precision estimates

    NASA Astrophysics Data System (ADS)

    Ammerlaan, B. A. J.; Holzinger, R.; Jedynska, A. D.; Henzing, J. S.

    2017-09-01

    Equivalent Black Carbon (EBC) and Elemental Carbon (EC) are different mass metrics to quantify the amount of combustion aerosol. Both metrics have their own measurement technique. In state-of-the-art carbon analysers, optical measurements are used to correct for organic carbon that is not evolving because of pyrolysis. These optical measurements are sometimes used to apply the technique of absorption photometers. Here, we use the transmission measurements of our carbon analyser for simultaneous determination of the elemental carbon concentration and the absorption coefficient. We use MAAP data from the CESAR observatory, the Netherlands, to correct for aerosol-filter interactions by linking the attenuation coefficient from the carbon analyser to the absorption coefficient measured by the MAAP. Application of the calibration to an independent data set of MAAP and OC/EC observations for the same location shows that the calibration is applicable to other observation periods. Because of simultaneous measurements of light absorption properties of the aerosol and elemental carbon, variation in the mass absorption efficiency (MAE) can be studied. We further show that the absorption coefficients and MAE in this set-up are determined within a precision of 10% and 12%, respectively. The precisions could be improved to 4% and 8% when the light transmission signal in the carbon analyser is very stable.

  9. Understanding the interacted mechanism between carbonation and chloride aerosol attack in ordinary Portland cement concrete

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liu, Jun; Qiu, Qiwen; Chen, Xiaochi

    An experimental study is carried out with the aim to understand the interacted mechanism between carbonation and chloride aerosol attack in ordinary Portland cement (OPC) concrete. Effects of carbonation on the chloride profile, the chloride binding capacity and the chloride diffusion coefficient are evaluated. Besides, effect of chloride aerosol attack on the carbonation rate is investigated. Concrete specimens with three water-to-cement ratios (0.38, 0.47 and 0.53) are fabricated in this work. Tested results demonstrate that carbonation remarkably affects the chloride profile, reduces the chloride binding capacity, and also accelerates the rate of chloride ion diffusion of concrete. Besides, the presencemore » of chloride aerosol can lead to lower the carbonation depth and increase the pH value of carbonated concrete. Microscopic properties such as morphology, porosity, and pore size distribution for the contaminated concretes are explored by scanning electron microscope and mercury intrusion porosimetry, which provide strong evidence to these research findings.« less

  10. The characteristics of brown carbon aerosol during winter in Beijing

    NASA Astrophysics Data System (ADS)

    Cheng, Yuan; He, Ke-bin; Du, Zhen-yu; Engling, Guenter; Liu, Jiu-meng; Ma, Yong-liang; Zheng, Mei; Weber, Rodney J.

    2016-02-01

    Brown carbon (i.e., light-absorbing organic carbon, or BrC) exerts important effects on the environment and on climate in particular. Based on spectrophotometric absorption measurements on extracts of bulk aerosol samples, this study investigated the characteristics of BrC during winter in Beijing, China. Organic compounds extractable by methanol contributed approximately 85% to the organic carbon (OC) mass. Light absorption by the methanol extracts exhibited a strong wavelength dependence, with an average absorption Ångström exponent of 7.10 (fitted between 310 and 450 nm). Normalizing the absorption coefficient (babs) measured at 365 nm to the extractable OC mass yielded an average mass absorption efficiency (MAE) of 1.45 m2/g for the methanol extracts. This study suggests that light absorption by BrC could be comparable with black carbon in the spectral range of near-ultraviolet light. Our results also indicate that BrC absorption and thus BrC radiative forcing could be largely underestimated when using water-soluble organic carbon (WSOC) as a surrogate for BrC. Compared to previous work relying only on WSOC, this study provides a more comprehensive understanding of BrC aerosol based on methanol extraction.

  11. Simulations of exercise and brain effects of acute exposure to carbon monoxide in normal and vascular-diseased persons.

    EPA Science Inventory

    At some level, carboxyhemoglobin (RbCO) due to inhalation of carbon monoxide (CO) reduces maximum exercise duration in normal and ischemic heart patients. At high RbCO levels in normal subjects, brain function is also affected and behavioral performance is impaired. These are fin...

  12. Solar cycle variations in mesospheric carbon monoxide

    NASA Astrophysics Data System (ADS)

    Lee, Jae N.; Wu, Dong L.; Ruzmaikin, Alexander; Fontenla, Juan

    2018-05-01

    As an extension of Lee et al. (2013), solar cycle variation of carbon monoxide (CO) is analyzed with MLS observation, which covers more than thirteen years (2004-2017) including maximum of solar cycle 24. Being produced primarily by the carbon dioxide (CO2) photolysis in the lower thermosphere, the variations of the mesospheric CO concentration are largely driven by the solar cycle modulated ultraviolet (UV) variation. This solar signal extends down to the lower altitudes by the dynamical descent in the winter polar vortex, showing a time lag that is consistent with the average descent velocity. To characterize a global distribution of the solar impact, MLS CO is correlated with the SORCE measured total solar irradiance (TSI) and UV. As high as 0.8 in most of the polar mesosphere, the linear correlation coefficients between CO and UV/TSI are more robust than those found in the previous work. The photochemical contribution explains most (68%) of the total variance of CO while the dynamical contribution accounts for 21% of the total variance at upper mesosphere. The photochemistry driven CO anomaly signal is extended in the tropics by vertical mixing. The solar cycle signal in CO is further examined with the Whole Atmosphere Community Climate Model (WACCM) 3.5 simulation by implementing two different modeled Spectral Solar Irradiances (SSIs): SRPM 2012 and NRLSSI. The model simulations underestimate the mean CO amount and solar cycle variations of CO, by a factor of 3, compared to those obtained from MLS observation. Different inputs of the solar spectrum have small impacts on CO variation.

  13. An Improved Extraction and Analysis Technique for Determination of Carbon Monoxide Stable Isotopes and Mixing Ratios from Ice Core and Atmospheric Air Samples.

    NASA Astrophysics Data System (ADS)

    Place, P., Jr.; Petrenko, V. V.; Vimont, I.

    2017-12-01

    Carbon Monoxide (CO) is an important atmospheric trace gas that affects the oxidative capacity of the atmosphere and contributes indirectly to anthropogenic radiative forcing. Carbon monoxide stable isotopes can also serve as a tracer for variations in biomass burning, particularly in the preindustrial atmosphere. A good understanding of the past variations in CO mole fractions and isotopic composition can help improve the skill of chemical transport models and constrain biomass burning changes. Ice cores may preserve a record of past atmospheric CO for analysis and interpretation. To this end, a new extraction system has been developed for analysis of stable isotopes (δ13CO and δC18O) of atmospheric carbon monoxide from ice core and atmospheric air samples. This system has been designed to measure relatively small sample sizes (80 cc STP of air) to accommodate the limited availability of ice core samples. Trapped air is extracted from ice core samples via melting in a glass vacuum chamber. This air is expanded into a glass expansion loop and then compressed into the sample loop of a Reducing Gas Detector (Peak Laboratories, Peak Performer 1 RCP) for the CO mole fraction measurement. The remaining sample gas will be expelled from the melt vessel into a larger expansion loop via headspace compression for isotopic analysis. The headspace compression will be accomplished by introduction of clean degassed water into the bottom of the melt vessel. Isotopic analysis of the sample gas is done utilizing the Schütze Reagent to convert the carbon monoxide to carbon dioxide (CO2) which is then measured using continuous-flow isotope ratio mass spectrometry (Elementar Americas, IsoPrime 100). A series of cryogenic traps are used to purify the sample air, capture the converted sample CO2, and cryofocus the sample CO2 prior to injection.

  14. Quantification of black carbon mixing state from traffic: Implications for aerosol optical properties

    DOE PAGES

    Willis, Megan D.; Healy, Robert M.; Riemer, Nicole; ...

    2016-04-14

    The climatic impacts of black carbon (BC) aerosol, an important absorber of solar radiation in the atmosphere, remain poorly constrained and are intimately related to its particle-scale physical and chemical properties. Using particle-resolved modelling informed by quantitative measurements from a soot-particle aerosol mass spectrometer, we confirm that the mixing state (the distribution of co-emitted aerosol amongst fresh BC-containing particles) at the time of emission significantly affects BC-aerosol optical properties even after a day of atmospheric processing. Both single particle and ensemble aerosol mass spectrometry observations indicate that BC near the point of emission co-exists with hydrocarbon-like organic aerosol (HOA) inmore » two distinct particle types: HOA-rich and BC-rich particles. The average mass fraction of black carbon in HOA-rich and BC-rich particle classes was < 0.1 and 0.8, respectively. Notably, approximately 90 % of BC mass resides in BC-rich particles. This new measurement capability provides quantitative insight into the physical and chemical nature of BC-containing particles and is used to drive a particle-resolved aerosol box model. Lastly, significant differences in calculated single scattering albedo (an increase of 0.1) arise from accurate treatment of initial particle mixing state as compared to the assumption of uniform aerosol composition at the point of BC injection into the atmosphere.« less

  15. Black carbon aerosol size in snow.

    PubMed

    Schwarz, J P; Gao, R S; Perring, A E; Spackman, J R; Fahey, D W

    2013-01-01

    The effect of anthropogenic black carbon (BC) aerosol on snow is of enduring interest due to its consequences for climate forcing. Until now, too little attention has been focused on BC's size in snow, an important parameter affecting BC light absorption in snow. Here we present first observations of this parameter, revealing that BC can be shifted to larger sizes in snow than are typically seen in the atmosphere, in part due to the processes associated with BC removal from the atmosphere. Mie theory analysis indicates a corresponding reduction in BC absorption in snow of 40%, making BC size in snow the dominant source of uncertainty in BC's absorption properties for calculations of BC's snow albedo climate forcing. The shift reduces estimated BC global mean snow forcing by 30%, and has scientific implications for our understanding of snow albedo and the processing of atmospheric BC aerosol in snowfall.

  16. Desert dust and anthropogenic aerosol interactions in the Community Climate System Model coupled-carbon-climate model

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mahowald, Natalie; Rothenberg, D.; Lindsay, Keith

    2011-02-01

    Coupled-carbon-climate simulations are an essential tool for predicting the impact of human activity onto the climate and biogeochemistry. Here we incorporate prognostic desert dust and anthropogenic aerosols into the CCSM3.1 coupled carbon-climate model and explore the resulting interactions with climate and biogeochemical dynamics through a series of transient anthropogenic simulations (20th and 21st centuries) and sensitivity studies. The inclusion of prognostic aerosols into this model has a small net global cooling effect on climate but does not significantly impact the globally averaged carbon cycle; we argue that this is likely to be because the CCSM3.1 model has a small climatemore » feedback onto the carbon cycle. We propose a mechanism for including desert dust and anthropogenic aerosols into a simple carbon-climate feedback analysis to explain the results of our and previous studies. Inclusion of aerosols has statistically significant impacts on regional climate and biogeochemistry, in particular through the effects on the ocean nitrogen cycle and primary productivity of altered iron inputs from desert dust deposition.« less

  17. Paediatric emergency department-based carbon monoxide detector intervention: a randomised trial

    PubMed Central

    McKenzie, Lara B; Roberts, Kristin J; Kaercher, Roxanne M; Collins, Christy L; Comstock, R Dawn; Fernandez, Soledad; Abdel-Rasoul, Mahmoud; Casavant, Marcel J; Mihalov, Leslie

    2017-01-01

    Background Although non-fire-related carbon monoxide (CO) poisoning is almost entirely preventable, over 400 people die and 20 000 people are injured each year in the USA from unintentional CO poisoning. Thus, there is a critical need for evidence-based interventions for preventing CO poisoning and increasing the proper use and installation of CO detectors. Methods A randomised, controlled trial (Project CODE, a Carbon Monoxide Detector Education intervention) with 2-week and 6-month follow-up home observations was conducted in 299 parents of children aged ≤18 years recruited in the emergency department of a level 1 paediatric trauma centre. The intervention group received an educational tool, a spiral-bound, laminated booklet that resembled a CO detector containing theory-based safety messages based on the precaution adoption process model, a plug-in CO detector and 9 V battery. The control group received a one page flyer on CO poisoning prevention. Results Although the difference was not statistically significant, mean CO knowledge score increased at a greater rate for the intervention group than the control group. Intervention group parents were more likely to exhibit ‘safe’ CO detector use than control group parents at the 2-week follow-up (RR: 2.75; 95% CI 2.06 to 3.69) and 6-month follow-up (RR: 2.78; 95% CI 2.06 to 3.76), after adjusting for self-reported CO detector use behaviour at enrolment and annual per capita income. Conclusions An emergency department-delivered intervention containing a theory-based educational tool paired with a CO detector can be an effective method for increasing knowledge about CO poisoning, for prevention and for appropriate use of a CO detector. Trial registration number NCT00959478. PMID:28007971

  18. Paediatric emergency department-based carbon monoxide detector intervention: a randomised trial.

    PubMed

    McKenzie, Lara B; Roberts, Kristin J; Kaercher, Roxanne M; Collins, Christy L; Comstock, R Dawn; Fernandez, Soledad; Abdel-Rasoul, Mahmoud; Casavant, Marcel J; Mihalov, Leslie

    2017-10-01

    Although non-fire-related carbon monoxide (CO) poisoning is almost entirely preventable, over 400 people die and 20 000 people are injured each year in the USA from unintentional CO poisoning. Thus, there is a critical need for evidence-based interventions for preventing CO poisoning and increasing the proper use and installation of CO detectors. A randomised, controlled trial (Project CODE, a Carbon Monoxide Detector Education intervention) with 2-week and 6-month follow-up home observations was conducted in 299 parents of children aged ≤18 years recruited in the emergency department of a level 1 paediatric trauma centre. The intervention group received an educational tool, a spiral-bound, laminated booklet that resembled a CO detector containing theory-based safety messages based on the precaution adoption process model, a plug-in CO detector and 9 V battery. The control group received a one page flyer on CO poisoning prevention. Although the difference was not statistically significant, mean CO knowledge score increased at a greater rate for the intervention group than the control group. Intervention group parents were more likely to exhibit 'safe' CO detector use than control group parents at the 2-week follow-up (RR: 2.75; 95% CI 2.06 to 3.69) and 6-month follow-up (RR: 2.78; 95% CI 2.06 to 3.76), after adjusting for self-reported CO detector use behaviour at enrolment and annual per capita income. An emergency department-delivered intervention containing a theory-based educational tool paired with a CO detector can be an effective method for increasing knowledge about CO poisoning, for prevention and for appropriate use of a CO detector. NCT00959478. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  19. Relation of Hydrogen and Methane to Carbon Monoxide in Exhaust Gases from Internal-Combustion Engines

    NASA Technical Reports Server (NTRS)

    Gerrish, Harold C; Tessmann, Arthur M

    1935-01-01

    The relation of hydrogen and methane to carbon monoxide in the exhaust gases from internal-combustion engines operating on standard-grade aviation gasoline, fighting-grade aviation gasoline, hydrogenated safety fuel, laboratory diesel fuel, and auto diesel fuel was determined by analysis of the exhaust gases. Two liquid-cooled single-cylinder spark-ignition, one 9-cylinder radial air-cooled spark-ignition, and two liquid-cooled single-cylinder compression-ignition engines were used.

  20. Inhalation Exposures to Particulate Matter and Carbon Monoxide during Ethiopian Coffee Ceremonies in Addis Ababa: A Pilot Study

    PubMed Central

    Keil, Chris; Kassa, Hailu; Brown, Alexander; Kumie, Abera; Tefera, Worku

    2010-01-01

    The unique Ethiopian cultural tradition of the coffee ceremony increases inhalation exposures to combustion byproducts. This pilot study evaluated exposures to particulate matter and carbon monoxide in ten Addis Ababa homes during coffee ceremonies. For coffee preparers the geometric mean (57 μg/m3) and median (72 μg/m3) contributions to an increase in a 24-hour time-weighted average exposure were above World Health Organization (WHO) guidelines. At 40% of the study sites the contribution to the 24-hour average exposure was greater than twice the WHO guideline. Similar exposure increases existed for ceremony participants. Particulate matter concentrations may be related to the use of incense during the ceremony. In nearly all homes the WHO guideline for a 60-minute exposure to carbon monoxide was exceeded. Finding control measures to reduce these exposures will be challenging due to the deeply engrained nature of this cultural practice and the lack of availability of alternative fuels. PMID:20886061