  1. Atrial fibrillation ablation using a closed irrigation radiofrequency ablation catheter.

    PubMed

    Golden, Keith; Mounsey, John Paul; Chung, Eugene; Roomiani, Pahresah; Morse, Michael Andew; Patel, Ankit; Gehi, Anil

    2012-05-01

    Catheter ablation is an effective therapy for symptomatic, medically refractory atrial fibrillation (AF). Open-irrigated radiofrequency (RF) ablation catheters produce transmural lesions at the cost of increased fluid delivery. In vivo models suggest closed-irrigated RF catheters create equivalent lesions, but clinical outcomes are limited. A cohort of 195 sequential patients with symptomatic AF underwent stepwise AF ablation (AFA) using a closed-irrigation ablation catheter. Recurrence of AF was monitored and outcomes were evaluated using Kaplan-Meier survival analysis and Cox proportional hazards models. Mean age was 59.0 years, 74.9% were male, 56.4% of patients were paroxysmal and mean duration of AF was 5.4 years. Patients had multiple comorbidities including hypertension (76.4%), tobacco abuse (42.1%), diabetes (17.4%), and obesity (mean body mass index 30.8). The median follow-up was 55.8 weeks. Overall event-free survival was 73.6% with one ablation and 77.4% after reablation (reablation rate was 8.7%). Median time to recurrence was 26.9 weeks. AF was more likely to recur in patients being treated with antiarrhythmic therapy at the time of last follow-up (recurrence rate 30.3% with antiarrhythmic drugs, 13.2% without antiarrhythmic drugs; hazard ratio [HR] 2.2, 95% confidence interval [CI] 1.1-4.4, P = 0.024) and in those with a history of AF greater than 2 years duration (HR 2.7, 95% CI 1.1-6.9, P = 0.038). Our study represents the largest cohort of patients receiving AFA with closed-irrigation ablation catheters. We demonstrate comparable outcomes to those previously reported in studies of open-irrigation ablation catheters. Given the theoretical benefits of a closed-irrigation system, a large head-to-head comparison using this catheter is warranted. ©2012, The Authors. Journal compilation ©2012 Wiley Periodicals, Inc.

  2. Biomarkers in Persistent AF and Heart Failure: Impact of Catheter Ablation Compared with Rate Control.

    PubMed

    Jones, David G; Haldar, Shouvik K; Donovan, Jacqueline; McDonagh, Theresa A; Sharma, Rakesh; Hussain, Wajid; Markides, Vias; Wong, Tom

    2016-09-01

    To investigate the effects of catheter ablation and rate control strategies on cardiac and inflammatory biomarkers in patients with heart failure and persistent atrial fibrillation (AF). Patients were recruited from the ARC-HF trial (catheter Ablation vs Rate Control for management of persistent AF in Heart Failure, NCT00878384), which compared ablation with rate control for persistent AF in heart failure. B-type natriuretic peptide (BNP), midregional proatrial natriuretic peptide (MR-proANP), apelin, and interleukin-6 (IL-6) were assayed at baseline, 3 months, 6 months, and 12 months. The primary end point, analyzed per-protocol, was changed from baseline at 12 months. Of 52 recruited patients, 24 ablation and 25 rate control subjects were followed to 12 months. After 1.2 ± 0.5 procedures, sinus rhythm was present in 22 (92%) ablation patients; under rate control, rate criteria were achieved in 23 (96%) of 24 patients remaining in AF. At 12 months, MR-proANP fell significantly in the ablation arm (-106.0 pmol/L, interquartile range [IQR] -228.2 to -60.6) compared with rate control (-28.7 pmol/L, IQR -69 to +9.5, P = 0.028). BNP showed a similar trend toward reduction (P = 0.051), with no significant difference in apelin (P = 0.13) or IL-6 (P = 0.68). Changes in MR-proANP and BNP correlated with peak VO2 and ejection fraction, and MR-proANP additionally with quality-of-life score. Catheter ablation, compared with rate control, in patients with heart failure and persistent AF was associated with significant reduction in MR-proANP, which correlated with physiological and symptomatic improvement. Ablation-based rhythm control may induce beneficial cardiac remodeling, unrelated to changes in inflammatory state. This may have prognostic implications, which require confirmation by event end point studies. © 2016 Wiley Periodicals, Inc.

  3. Catheter ablation in patients with persistent atrial fibrillation

    PubMed Central

    Kirchhof, Paulus; Calkins, Hugh

    2017-01-01

    Catheter ablation is increasingly offered to patients who suffer from symptoms due to atrial fibrillation (AF), based on a growing body of evidence illustrating its efficacy compared with antiarrhythmic drug therapy. Approximately one-third of AF ablation procedures are currently performed in patients with persistent or long-standing persistent AF. Here, we review the available information to guide catheter ablation in these more chronic forms of AF. We identify the following principles: Our clinical ability to discriminate paroxysmal and persistent AF is limited. Pulmonary vein isolation is a reasonable and effective first approach for catheter ablation of persistent AF. Other ablation strategies are being developed and need to be properly evaluated in controlled, multicentre trials. Treatment of concomitant conditions promoting recurrent AF by life style interventions and medical therapy should be a routine adjunct to catheter ablation of persistent AF. Early rhythm control therapy has a biological rationale and trials evaluating its value are underway. There is a clear need to generate more evidence for the best approach to ablation of persistent AF beyond pulmonary vein isolation in the form of adequately powered controlled multi-centre trials. PMID:27389907

  4. Is AF Ablation Cost Effective?

    PubMed Central

    Martin-Doyle, William; Reynolds, Matthew R.

    2010-01-01

    The use of catheter ablation to treat AF is increasing rapidly, but there is presently an incomplete understanding of its cost-effectiveness. AF ablation procedures involve significant up-front expenditures, but multiple randomized trials have demonstrated that ablation is more effective than antiarrhythmic drugs at maintaining sinus rhythm in a second-line and possibly first-line rhythm control setting. Although truly long-term data are limited, ablation, as compared with antiarrrhythmic drugs, also appears associated with improved symptoms and quality of life and a reduction in downstream hospitalization and other health care resource utilization. Several groups have developed cost effectiveness models comparing AF ablation primarily to antiarrhythmic drugs and the model results suggest that ablation likely falls within the range generally accepted as cost-effective in developed nations. This paper will review available information on the cost-effectiveness of catheter ablation for the treatment of atrial fibrillation, and discuss continued areas of uncertainty where further research is required. PMID:20936083

  5. Attitudes toward Catheter Ablation for Atrial Fibrillation: A Nationwide Survey among Danish Cardiologists.

    PubMed

    Vadmann, Henrik; Pedersen, Susanne S; Nielsen, Jens Cosedis; Rodrigo-Domingo, Maria; Pehrson, Steen; Johannessen, Arne; Hansen, Peter Steen; Johansen, Jens Brock; Riahi, Sam

    2015-10-01

    Catheter ablation for atrial fibrillation (AF) is an important but expensive procedure that is the subject of some debate. Physicians' attitudes toward catheter ablation may influence promotion and patient acceptance. This is the first study to examine the attitudes of Danish cardiologists toward catheter ablation for AF, using a nationwide survey. We developed a purpose-designed questionnaire to evaluate attitudes toward catheter ablation for AF that was sent to all Danish cardiologists (n = 401; response n = 272 (67.8%)). There was no association between attitudes toward ablation and the experience or age of the cardiologist with respect to patients with recurrent AF episodes with a duration of <48 hours or >7 days and/or need for cardioversion. The majority (69%) expected a recurrence of AF after catheter ablation in more than 30% of the cases. For patients with persistent longstanding AF with a duration of >1 year, the attitude toward ablation for longstanding AF was more likely to be positive with increasing age (P < 0.01) and years of experience of the cardiologist (P = 0.002). Danish cardiologists generally have a positive attitude toward catheter ablation for AF, maintain up-to-date knowledge of the procedure, and are aware what information on ablation treatment should be given to patients with AF. The cardiologists had a positive attitude toward ablation for AF in patients with AF episodes <48 hours and patients with episodes >7 days, or those who needed medical/electrical conversion, but a more negative attitude toward treating longstanding AF patients. © 2015 Wiley Periodicals, Inc.

  6. Catheter ablation of atrial fibrillation using remote magnetic catheter navigation: a case-control study.

    PubMed

    Arya, Arash; Zaker-Shahrak, Ruzbeh; Sommer, Phillip; Bollmann, Andreas; Wetzel, Ulrike; Gaspar, Thomas; Richter, Sergio; Husser, Daniela; Piorkowski, Christopher; Hindricks, Gerhard

    2011-01-01

    To compare the acute and the 6 month outcome of catheter ablation of atrial fibrillation (AF) using irrigated tip magnetic catheter and remote magnetic cathter navigation (RMN) with manual catheter navigation (MCN) in patients with paroxysmal and persistent AF. In this retrospective analysis 356 patients (235 male, mean age: 57.9 ± 10.9 years) with AF (70.5%, paroxysmal) who underwent catheter ablation between August 2007 and May 2008 using either RMN (n = 70, 46 male, mean age: 57.9 ± 10.1 years, 50% paroxysmal) or MCN (n = 286, 189 male, mean age: 58.0 ± 13.9 years, 75.5% paroxysmal) were included. All patients completed an intensive follow-up strategy. Complete pulmonary vein isolation was achieved in 87.6 and 99.6% of patients in RMN and MCN groups, respectively (P < 0.05). The procedure, fluoroscopy, and radiofrequency application times were 223 ± 44 vs. 166 ± 52 min (P < 0.0001), 13.7 ± 7.8 vs. 34.5 ± 15.1 min (P < 0.0001), and 75.4 ± 20.9 vs. 53.2 ± 21.4 min (P < 0.0001) in RMN and MCN groups, respectively. Seven (10.0%) and 28 (9.8%) patients in RMN and MCN groups received antiarrhythmic medications during the follow-up (P = 0.96). All the patients completed the 6 month follow-up. Freedom from AF at 6 months was achieved in 57.8 and 66.4% of the patients in RMN and MCN groups, respectively (P = 0.196). In patients without previous AF catheter ablation procedure the freedom from AF at 6 months were 68.2 and 60.5% in the MCN and RMN groups, respectively (P = 0.36). Catheter ablation using irrigated tip magnetic catheter and RMN is an effective and safe method for catheter ablation of AF. Compared to manual catheter navigation, the procedure and radiofrequency application times were longer and fluoroscopy time was shorter in the RMN group compared with the MCN group.

  7. Catheter Ablation versus Thoracoscopic Surgical Ablation in Long Standing Persistent Atrial Fibrillation (CASA-AF): study protocol for a randomised controlled trial.

    PubMed

    Khan, Habib Rehman; Kralj-Hans, Ines; Haldar, Shouvik; Bahrami, Toufan; Clague, Jonathan; De Souza, Anthony; Francis, Darrel; Hussain, Wajid; Jarman, Julian; Jones, David Gareth; Mediratta, Neeraj; Mohiaddin, Raad; Salukhe, Tushar; Jones, Simon; Lord, Joanne; Murphy, Caroline; Kelly, Joanna; Markides, Vias; Gupta, Dhiraj; Wong, Tom

    2018-02-20

    Atrial fibrillation is the commonest arrhythmia which raises the risk of heart failure, thromboembolic stroke, morbidity and death. Pharmacological treatments of this condition are focused on heart rate control, rhythm control and reduction in risk of stroke. Selective ablation of cardiac tissues resulting in isolation of areas causing atrial fibrillation is another treatment strategy which can be delivered by two minimally invasive interventions: percutaneous catheter ablation and thoracoscopic surgical ablation. The main purpose of this trial is to compare the effectiveness and safety of these two interventions. Catheter Ablation versus Thoracoscopic Surgical Ablation in Long Standing Persistent Atrial Fibrillation (CASA-AF) is a prospective, multi-centre, randomised controlled trial within three NHS tertiary cardiovascular centres specialising in treatment of atrial fibrillation. Eligible adults (n = 120) with symptomatic, long-standing, persistent atrial fibrillation will be randomly allocated to either catheter ablation or thoracoscopic ablation in a 1:1 ratio. Pre-determined lesion sets will be delivered in each treatment arm with confirmation of appropriate conduction block. All patients will have an implantable loop recorder (ILR) inserted subcutaneously immediately following ablation to enable continuous heart rhythm monitoring for at least 12 months. The devices will be programmed to detect episodes of atrial fibrillation and atrial tachycardia ≥ 30 s in duration. The patients will be followed for 12 months, completing appropriate clinical assessments and questionnaires every 3 months. The ILR data will be wirelessly transmitted daily and evaluated every month for the duration of the follow-up. The primary endpoint in the study is freedom from atrial fibrillation and atrial tachycardia at the end of the follow-up period. The CASA-AF Trial is a National Institute for Health Research-funded study that will provide first-class evidence on the

  8. Efficacy of Antiarrhythmic Drugs Short-Term Use After Catheter Ablation for Atrial Fibrillation (EAST-AF) trial.

    PubMed

    Kaitani, Kazuaki; Inoue, Koichi; Kobori, Atsushi; Nakazawa, Yuko; Ozawa, Tomoya; Kurotobi, Toshiya; Morishima, Itsuro; Miura, Fumiharu; Watanabe, Tetsuya; Masuda, Masaharu; Naito, Masaki; Fujimoto, Hajime; Nishida, Taku; Furukawa, Yoshio; Shirayama, Takeshi; Tanaka, Mariko; Okajima, Katsunori; Yao, Takenori; Egami, Yasuyuki; Satomi, Kazuhiro; Noda, Takashi; Miyamoto, Koji; Haruna, Tetsuya; Kawaji, Tetsuma; Yoshizawa, Takashi; Toyota, Toshiaki; Yahata, Mitsuhiko; Nakai, Kentaro; Sugiyama, Hiroaki; Higashi, Yukei; Ito, Makoto; Horie, Minoru; Kusano, Kengo F; Shimizu, Wataru; Kamakura, Shiro; Morimoto, Takeshi; Kimura, Takeshi; Shizuta, Satoshi

    2016-02-14

    Substantial portion of early arrhythmia recurrence after catheter ablation for atrial fibrillation (AF) is considered to be due to irritability in left atrium (LA) from the ablation procedure. We sought to evaluate whether 90-day use of antiarrhythmic drug (AAD) following AF ablation could reduce the incidence of early arrhythmia recurrence and thereby promote reverse remodelling of LA, leading to improved long-term clinical outcomes. A total of 2038 patients who had undergone radiofrequency catheter ablation for paroxysmal, persistent, or long-lasting AF were randomly assigned to either 90-day use of Vaughan Williams class I or III AAD (1016 patients) or control (1022 patients) group. The primary endpoint was recurrent atrial tachyarrhythmias lasting for >30 s or those requiring repeat ablation, hospital admission, or usage of class I or III AAD at 1 year, following the treatment period of 90 days post ablation. Patients assigned to AAD were associated with significantly higher event-free rate from recurrent atrial tachyarrhythmias when compared with the control group during the treatment period of 90 days [59.0 and 52.1%, respectively; adjusted hazard ratio (HR) 0.84; 95% confidence interval (CI) 0.73-0.96; P = 0.01]. However, there was no significant difference in the 1-year event-free rates from the primary endpoint between the groups (69.5 and 67.8%, respectively; adjusted HR 0.93; 95% CI 0.79-1.09; P = 0.38). Short-term use of AAD for 90 days following AF ablation reduced the incidence of recurrent atrial tachyarrhythmias during the treatment period, but it did not lead to improved clinical outcomes at the later phase. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2015. For permissions please email: journals.permissions@oup.com.

  9. Left Atrial Anatomy Relevant to Catheter Ablation

    PubMed Central

    Sánchez-Quintana, Damián; Cabrera, José Angel; Saremi, Farhood

    2014-01-01

    The rapid development of interventional procedures for the treatment of arrhythmias in humans, especially the use of catheter ablation techniques, has renewed interest in cardiac anatomy. Although the substrates of atrial fibrillation (AF), its initiation and maintenance, remain to be fully elucidated, catheter ablation in the left atrium (LA) has become a common therapeutic option for patients with this arrhythmia. Using ablation catheters, various isolation lines and focal targets are created, the majority of which are based on gross anatomical, electroanatomical, and myoarchitectual patterns of the left atrial wall. Our aim was therefore to review the gross morphological and architectural features of the LA and their relations to extracardiac structures. The latter have also become relevant because extracardiac complications of AF ablation can occur, due to injuries to the phrenic and vagal plexus nerves, adjacent coronary arteries, or the esophageal wall causing devastating consequences. PMID:25057427

  10. Are left ventricular ejection fraction and left atrial diameter related to atrial fibrillation recurrence after catheter ablation?

    PubMed Central

    Jin, Xiao; Pan, Jianke; Wu, Huanlin; Xu, Danping

    2018-01-01

    Abstract Atrial fibrillation (AF), the most common form of arrhythmia, is associated with the prevalence of many common cardiovascular and cerebrovascular diseases. Catheter ablation is considered the first-line therapy for AF; however, AF recurrence is very common after catheter ablation. Studies have been performed to analyze the factors associated with AF recurrence, but none have reached a consistent conclusion on whether left ventricular ejection fraction (LVEF) and left atrial diameter (LA diameter) affect AF recurrence after catheter ablation. The databases PubMed, Embase, and the Cochrane Library were used to search for relevant studies up to September 2017. RevMan 5.3.5 software provided by the Cochrane Collaboration Network was used to conduct this meta-analysis. Thirteen studies involving 2825 patients were included in this meta-analysis. Overall, the results revealed that elevated LA diameter values were significantly associated with AF recurrence in patients after catheter ablation (MD = 2.19, 95% CI: 1.63–2.75, P < .001), while baseline LVEF levels were not significantly positively associated with AF recurrence in patients after catheter ablation (MD = −0.91, 95% CI: −1.18 to 1.67, P = .14). Overall, elevated LA diameter may be associated with AF recurrence after catheter ablation; however, there was no direct relationship between LVEF values and AF recurrence after catheter ablation when baseline LVEF values are normal or mildly decreased. Besides, because of publication bias, further studies should be performed to explore the mechanisms underlying AF recurrence. PMID:29768386

  11. Cost Analysis of Periprocedural Imaging in Patients Undergoing Catheter Ablation for Atrial Fibrillation

    PubMed Central

    Pokorney, Sean D.; Hammill, Bradley G.; Qualls, Laura G.; Steinberg, Benjamin A.; Curtis, Lesley H.; Piccini, Jonathan P.

    2014-01-01

    Cardiovascular imaging is an important part of procedural planning and safety for catheter ablation of atrial fibrillation (AF). However, the costs of imaging surrounding catheter ablation of AF have not been described. Medicare fee-for-service data were used to evaluate Medicare expenditures before, during, and after catheter ablation for AF from July 2007 to December 2009. Among 11,525 patients who underwent catheter ablation for AF, the mean overall expenditure on the day of the procedure was $14,455 (SD $7,441). The mean imaging expenditure in the periprocedural period, which included the 30 days before the catheter ablation and the day of the ablation itself, was $884 (SD $455). Periprocedural imaging expenditures varied by the imaging strategy used, ranging from a mean of $557 (SD $269) for patients with electroanatomic mapping only to $1,234 (SD $461) for patients with electroanatomic mapping, transesophageal echocardiogram, and computed tomography or magnetic resonance imaging. Mean patient-level imaging expenditures varied by provider (mean $872, SD $249). Periprocedural imaging expenditures also varied by patient risk, with mean expenditures of $862 (SD $444) for patients with a CHADS2 score of ≥2 compared with $907 (SD $466) for CHADS2 score <2 (p <0.001). In conclusion, peri-procedural imaging accounts for approximately 6% of mean Medicare expenditures for catheter ablation of AF. The expenditures for periprocedural imaging vary both at the patient and at the provider level and they are inversely related to stroke risk by CHADS2 score. PMID:24952929

  12. Persistent Atrial Fibrillation Ablation using the Tip-Versatile Ablation Catheter.

    PubMed

    Davies, Edward J; Clayton, Ben; Lines, Ian; Haywood, Guy A

    2016-07-01

    The mechanisms by which persistent atrial fibrillation (PsAF) develops are incompletely understood. Consequently, the optimal strategy for the ablative management of PsAF remains debated. Current methods are often time consuming, complex and non-reproducible. We assessed the Tip-Versatile Ablation Catheter (T-VAC) technique, a rapidly delivered, empirical technique based on the box-set concept using duty-cycled linear catheter ablation technology. Forty-four procedures in 40 patients undergoing PsAF ablation with the novel technique were prospectively entered onto a database: 27 de novo. Primary endpoint was freedom from arrhythmia at over two-year follow-up. Secondary endpoints were time to first arrhythmia recurrence, freedom from atrial fibrillation (AF) on and off antiarrhythmic drugs (AAD), procedural and fluoroscopy duration and complication rate. At mean follow-up of 33 months, absolute freedom from arrhythmia recurrence was 45% in the de novo group. Overall, at 33 (IQR 24-63) months, 60% of de novo patients were in sustained normal sinus rhythm and a further 15% reported only occasional paroxysms of AF at long-term follow-up. Procedure time was 192±25 mins, total energy delivered 2239±883s and fluoroscopy time was 60±10mins. In selected patients with persistent AF, a long-term rate of 60% arrhythmia free survival off AAD can be achieved using this novel T-VAC technique. Copyright © 2016 Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). Published by Elsevier B.V. All rights reserved.

  13. Persistent Atrial Fibrillation Ablation in Females: Insight from the MAGIC-AF Trial.

    PubMed

    Singh, Sheldon M; D'Avila, Andre; Aryana, Arash; Kim, Young-Hoon; Mangrum, J Michael; Michaud, Gregory F; Dukkipati, Srinivas R; Heist, E Kevin; Barrett, Conor D; Thorpe, Kevin E; Reddy, Vivek Y

    2016-07-27

    Atrial fibrillation (AF) ablation is less frequently performed in women when compared to men. There are conflicting data on the safety and efficacy of AF ablation in women. The objective of this study was to compare the clinical characteristics and outcomes in a contemporary cohort of men and women undergoing persistent AF ablation procedures. A total of 182 men and 53 women undergoing a first-ever persistent AF catheter ablation procedure in The Modified Ablation Guided by Ibutilide Use in Chronic Atrial Fibrillation (MAGIC-AF) trial were evaluated. Clinical and procedural characteristics were compared between each gender. The primary efficacy endpoint was the 1-year single procedure freedom from atrial arrhythmia off anti-arrhythmic drugs. Women undergoing catheter ablation procedures were older than men (P < 0.001). The duration of AF and associated co-morbidities were similar between both genders. Single procedure drug-free atrial arrhythmia recurrence occurred in 53% of the cohort with no difference based on gender (men = 54%, women = 53%; P = 1.0). Procedural (P = 0.04), fluoroscopic (P = 0.02), and ablation times (P = 0.003) were shorter in women compared to men. Periprocedural complications and postablation improvement in quality of life were similar between men and women. Women undergoing a first-ever persistent AF ablation procedure were older but had similar clinical outcomes and complications when compared with men. © 2016 Wiley Periodicals, Inc.

  14. [Chronic outcome of patients with paroxysmal atrial fibrillation post catheter ablation].

    PubMed

    Lin, Yu-bi; Xia, Yun-long; Gao, Lian-jun; Chu, Zhen-liang; Cong, Pei-xin; Chang, Dong; Yin, Xiao-meng; Zhang, Shu-long; Yang, Dong-Hui; Yang, Yan-Zong

    2009-12-01

    High short-term successful rate was reported for catheter ablation in patients with paroxysmal atrial fibrillation (AF), we analyzed the long-term outcome (success rate, anticoagulation therapy and embolism event, anti-arrhythmic therapy and death post procedure) of catheter ablation for paroxysmal AF in this study. From January 2000 to December 2004, 106 consecutive patients with drug-refractory paroxysmal AF underwent catheter ablation and were followed-up for (60.7 + or - 11.8) months. Segmental pulmonary vein isolation (SPVI) was routinely performed by radiofrequency energy under the guidance of circular mapping catheter. The patients were followed up with 24 h-holter, ECG, telephone or letter. Data on recurrence of AF, the anticoagulation medication and the incidence of embolism, anti-arrhythmic therapy were obtained. There were 9 patients lost to follow up. In the remaining 97 patients [65 males, (54.8 + or - 11.2) years old], 3 cases died from cancer, sinus rhythm was maintained in 68 patients (Group S, 72.3%) and AF recurrence evidenced in 26 patients (Group R, 27.7%). In Group S, 56 patients (82.4%) discontinued anticoagulation medication, and 12 patients continued to take aspirin. There was no embolism event in Group S during follow-up. In Group R, 1 patient continued to take warfarin; 11 patients continued to take aspirin and 2 patients suffered from cerebral embolism. Anticoagulation medication was discontinued in 14 patients (53.8%) and 1 patient suffered form cerebral embolism. The incidence of embolism event in Group R is significantly higher than in Group S (P < 0.01). More patients discontinued anti-arrhythmic medication in Group S than in Group R (80.9% vs. 56.0%, P < 0.05). Catheter ablation is associated with satisfactory long-term success rate, reduced anti-arrhythmia medication, improved quality of life in patients with paroxysmal AF.

  15. Atrial fibrillation ablation using very short duration 50 W ablations and contact force sensing catheters.

    PubMed

    Winkle, Roger A; Moskovitz, Ryan; Hardwin Mead, R; Engel, Gregory; Kong, Melissa H; Fleming, William; Salcedo, Jonathan; Patrawala, Rob A; Tranter, John H; Shai, Isaac

    2018-06-01

    The optimal radiofrequency (RF) power and lesion duration using contact force (CF) sensing catheters for atrial fibrillation (AF) ablation are unknown. We evaluate 50 W RF power for very short durations using CF sensing catheters during AF ablation. We evaluated 51 patients with paroxysmal (n = 20) or persistent (n = 31) AF undergoing initial RF ablation. A total of 3961 50 W RF lesions were given (average 77.6 ± 19.1/patient) for an average duration of only 11.2 ± 3.7 s. As CF increased from < 10 to > 40 g, the RF application duration decreased from 13.7 ± 4.4 to 8.6 ± 2.5 s (p < 0.0005). Impedance drops occurred in all ablations, and for patients in sinus rhythm, there was loss of pacing capture during RF delivery suggesting lesion creation. Only 3% of the ablation lesions were at < 5 g and 1% at > 40 g of force. As CF increased, the force time integral (FTI) increased from 47 ± 24 to 376 ± 102 gs (p < 0.0005) and the lesion index (LSI) increased from 4.10 ± 0.51 to 7.63 ± 0.50 (p < 0.0005). Both procedure time (101 ± 19.7 min) and total RF energy time (895 ± 258 s) were very short. For paroxysmal AF, the single procedure freedom from AF was 86% at 1 and 2 years. For persistent AF, it was 83% at 1 year and 72% at 2 years. There were no complications. Short duration 50 W ablations using CF sensing catheters are safe and result in excellent long-term freedom from AF for both paroxysmal and persistent AF with short procedure times and small amounts of total RF energy delivery.

  16. [Catheter ablation of atrial fibrillation: Health Technology Assessment Report from the Italian Association of Arrhythmology and Cardiac Pacing (AIAC)].

    PubMed

    Themistoclakis, Sakis; Tritto, Massimo; Bertaglia, Emanuele; Berto, Patrizia; Bongiorni, Maria Grazia; Catanzariti, Domenico; De Fabrizio, Giuseppe; De Ponti, Roberto; Grimaldi, Massimo; Pandozi, Claudio; Tondo, Claudio; Gulizia, Michele

    2011-11-01

    Atrial fibrillation (AF) is the most common sustained cardiac arrhythmia and significantly impact patients' quality of life, morbidity and mortality. The number of affected patients is expected to increase as well as the costs associated with AF management, mainly driven by hospitalizations. Over the last decade, catheter ablation techniques targeting pulmonary vein isolation have demonstrated to be effective in treating AF and preventing AF recurrence. This Health Technology Assessment report of the Italian Association of Arrhythmology and Cardiac Pacing (AIAC) aims to define the current role of catheter ablation of AF in terms of effectiveness, efficiency and appropriateness. On the basis of an extensive review of the available literature, this report provides (i) an overview of the epidemiology, clinical impact and socio-economic burden of AF; (ii) an evaluation of therapeutic options other than catheter ablation of AF; and (iii) a detailed presentation of clinical outcomes and cost-benefit ratio associated with catheter ablation. The costs of catheter ablation of AF in Italy were obtained using a bottom-up analysis of a resource utilization survey of 52 hospitals that were considered a representative sample, including 4 Centers that contributed with additional unit cost information in a separate questionnaire. An analysis of budget impact was also performed to evaluate the impact of ablation on the management costs of AF. Results of this analysis show that (1) catheter ablation is effective, safe and superior to antiarrhythmic drug therapy in maintaining sinus rhythm; (2) the cost of an ablation procedure in Italy typically ranges from €8868 to €9455, though current reimbursement remains insufficient, covering only about 60% of the costs; (3) the costs of follow-up are modest (about 8% of total costs); (4) assuming an adjustment of reimbursement to the real cost of an ablation procedure and a 5-10% increase in the annual rate of ablation procedures, after

  17. Safe and rapid isolation of pulmonary veins using a novel circular ablation catheter and duty-cycled RF generator.

    PubMed

    Fredersdorf, Sabine; Weber, Stefan; Jilek, Clemens; Heinicke, Norbert; VON Bary, Christian; Jungbauer, Carsten; Riegger, Günter A; Hamer, Okka W; Jeron, Andreas

    2009-10-01

    Ablation of atrial fibrillation (AF) has been one of the most difficult and time-consuming electrophysiological procedures. Due to the rapidly increasing demand for ablation procedures, technical advances would be helpful to reduce complexity and procedure time in AF ablation. Therefore, we investigated the feasibility of a single-catheter technique for pulmonary vein (PV) isolation utilizing a decapolar catheter combined with a duty-cycled, unipolar-bipolar radiofrequency (RF) generator. AF mapping and ablation was performed in 21 consecutive patients (mean age 59 +/- 12 years, 9 males) with paroxysmal AF (n = 17) and persistent AF (n = 4). The ablation catheter was forwarded to the LA via single-transseptal puncture. All electrodes were energized in 2 to 5 applications per vein, followed by segmental RF applications, as needed, to achieve electrical isolation. To assess left atrial anatomy for purposes of catheter manipulation, and later evaluate the possibility of asymptomatic PV-stenosis, CT or MR imaging was performed both prior to ablation and at 6-month follow-up. Isolation could be achieved in 85/86 veins (99%). Procedure time for ablation was 81 +/- 13 minutes, and fluoroscopy time was 30 +/- 11 minutes. There were no procedural complications. Success rate at 6 months was 86% (18/21). MR or CT imaging excluded asymptomatic PV-stenosis. Mapping and ablation of PVs can be performed in a safe and efficient manner using a single-catheter technique, with short procedure times and minimal learning curve. Thus, this system may be of high interest not only for high volume but all centers performing AF ablation.

  18. Catheter Ablation of Atrial Fibrillation in Patients with Hardware in the Heart - Septal Closure Devices, Mechanical Valves and More.

    PubMed

    Bartoletti, Stefano; Santangeli, Pasquale; DI Biase, Luigi; Natale, Andrea

    2013-01-01

    Patients with mechanical "hardware" in the heart, such as those with mechanical cardiac valves or atrial septal closure devices, represent a population at high risk of developing AF. Catheter ablation of AF in these subjects might represent a challenge, due to the perceived higher risk of complications associated with the presence of intracardiac mechanical devices. Accordingly, such patients were excluded or poorly represented in major trials proving the benefit of catheter ablation for the rhythm-control of AF. However, recent evidence supports the concept that catheter ablation procedures might be equally effective in these patients, without a significant increase in the risk of procedural complications. This review will summarize the current state-of-the-art on catheter ablation of AF in patients with mechanical "hardware" in the heart.

  19. Pacemaker implantation after catheter ablation for atrial fibrillation.

    PubMed

    Deshmukh, Abhishek J; Yao, Xiaoxi; Schilz, Stephanie; Van Houten, Holly; Sangaralingham, Lindsey R; Asirvatham, Samuel J; Friedman, Paul A; Packer, Douglas L; Noseworthy, Peter A

    2016-01-01

    Sinus node dysfunction requiring pacemaker implantation is commonly associated with atrial fibrillation (AF), but may not be clinically apparent until restoration of sinus rhythm with ablation or cardioversion. We sought to determine frequency, time course, and predictors for pacemaker implantation after catheter ablation, and to compare the overall rates to a matched cardioversion cohort. We conducted a retrospective analysis using a large US commercial insurance database and identified 12,158 AF patients who underwent catheter ablation between January 1, 2005 and December 31, 2012. Over an average of 2.4 years of follow-up, 5.6 % of the patients underwent pacemaker implantation. Using the Cox proportional hazards models, we found that risk of risks of pacemaker implantation was associated with older age (50-64 and ≥65 versus <50 years), female gender, higher CHADS2 score (≥2 and 1 versus 0), higher Charlson index (≥2 versus 0-1), certain baseline comorbidities (conduction disorder, coronary atherosclerosis, and congestive heart failure), and the year of ablation. There was no significant difference in the risk of pacemaker implantation between ablation patients and propensity score (PS)-matched cardioversion groups (3.5 versus. 4.1 % at 1 year and 8.8 versus 8.3 % at 5 years). Overall, pacemaker implantation occurs in about 1/28 patients within 1 year of catheter ablation. The overall implantation rate decreased between 2005 and 2012. Furthermore, the risk after ablation is similar to cardioversion, suggesting that patients require pacing due to a common underlying electrophysiologic substrate, rather than the ablation itself.

  20. Catheter ablation of atrial fibrillation in patients with concomitant sinus bradycardia-Insights from the German Ablation Registry.

    PubMed

    Zylla, Maura M; Brachmann, Johannes; Lewalter, Thorsten; Hoffmann, Ellen; Kuck, Karl-Heinz; Andresen, Dietrich; Willems, Stephan; Hochadel, Matthias; Senges, Jochen; Katus, Hugo A; Thomas, Dierk

    2016-01-01

    This investigation addresses procedural characteristics of catheter ablation in patients with atrial fibrillation (AF) and sinus bradycardia. From the prospective, multi-center German Ablation Registry 1073 patients with sinus rhythm at the time of AF ablation were divided into two groups according to heart rate at start of procedure (A, <60 beats per minute (bpm), n=197; B, 60-99bpm, n=876). Acute procedural success was high (≥98%) and similar between groups. Procedure duration and energy application time were increased in group A (180min vs. 155min and 2561s vs. 1879s, respectively). Major complications were more frequent in group A (2.2% vs. 0.5%), and a greater proportion of these patients was discharged under antiarrhythmic medication (64% vs. 52%). Catheter ablation of AF with concomitant sinus bradycardia is associated with high procedural efficacy, longer procedure- and energy application durations, and a slightly elevated complication rate. Copyright © 2016 Elsevier Inc. All rights reserved.

  1. Outcomes of repeat catheter ablation using magnetic navigation or conventional ablation.

    PubMed

    Akca, Ferdi; Theuns, Dominic A M J; Abkenari, Lara Dabiri; de Groot, Natasja M S; Jordaens, Luc; Szili-Torok, Tamas

    2013-10-01

    After initial catheter ablation, repeat procedures could be necessary. This study evaluates the efficacy of the magnetic navigation system (MNS) in repeat catheter ablation as compared with manual conventional techniques (MANs). The results of 163 repeat ablation procedures were analysed. Ablations were performed either using MNS (n = 84) or conventional manual ablation (n = 79). Procedures were divided into four groups based on the technique used during the initial and repeat ablation procedure: MAN-MAN (n = 66), MAN-MNS (n = 31), MNS-MNS (n = 53), and MNS-MAN (n = 13). Three subgroups were analysed: supraventricular tachycardias (SVTs, n = 68), atrial fibrillation (AF, n = 67), and ventricular tachycardias (VT, n = 28). Recurrences were assessed during 19 ± 11 months follow-up. Overall, repeat procedures using MNS were successful in 89.0% as compared with 96.2% in the MAN group (P = ns). The overall recurrence rate was significantly lower using MNS (25.0 vs. 41.4%, P = 0.045). Acute success and recurrence rates for the MAN-MAN, MAN-MNS, MNS-MNS, and MNS-MAN groups were comparable. For the SVT subgroup a higher acute success rate was achieved using MAN (87.9 vs. 100.0%, P = 0.049). The use of MNS for SVT is associated with longer procedure times (205 ± 82 vs. 172 ± 69 min, P = 0.040). For AF procedure and fluoroscopy times were longer (257 ± 72 vs. 185 ± 64, P = 0.001; 59.5 ± 19.3 vs. 41.1 ± 18.3 min, P < 0.001). Less fluoroscopy was used for MNS-guided VT procedures (22.8 ± 14.7 vs. 41.2 ± 10.9, P = 0.011). Our data suggest that overall MNS is comparable with MAN in acute success after repeat catheter ablation. However, MNS is related to fewer recurrences as compared with MAN.

  2. Improvements In AF Ablation Outcome Will Be Based More On Technological Advancement Versus Mechanistic Understanding.

    PubMed

    Jiang Md, Chen-Yang; Jiang Ms, Ru-Hong

    2014-01-01

    Atrial fibrillation (AF) is one of the most common cardiac arrhythmias. Catheter ablation has proven more effective than antiarrhythmic drugs in preventing clinical recurrence of AF, however long-term outcome remains unsatisfactory. Ablation strategies have evolved based on progress in mechanistic understanding, and technologies have advanced continuously. This article reviews current mechanistic concepts and technological advancements in AF treatment, and summarizes their impact on improvement of AF ablation outcome.

  3. Atrial Fibrillation Radiofrequency Ablation: Safety Using Contact Force Catheter In A Low-Volume Centre.

    PubMed

    Vaccari Md, Diego; Giacopelli MSc, Daniele; Rocchetto MSc, Eros; Vittadello Md, Sabina; Mantovan Md, Roberto; Neri Md, Gianfilippo

    2014-01-01

    The tip-to-tissue contact force (CF) has been identified as a potential determinant of lesion quality during radiofrequency (RF) ablation. The aim of this paper is to report the experience of a single low-volume centre in the atrial fibrillation (AF) ablation procedure with an RF catheter capable of measuring this parameter. CF data and their possible implications on patient safety are presented. Thirty-nine consecutive patients suffering of paroxysmal or permanent AF received percutaneous ablation with the novel catheter studied. Procedural characteristics, CF applied and safety events related to the procedure were reported. During RF application the mean CF value was 17 ± 3 g, with a maximum mean value of 37 ± 8 g. CF value never exceeded 62 g and in the 74% of the RF applications ranged between 10 g and 30 g. No complication related to the catheter manipulation or to the energy delivered was observed. This study of a single centre with a low level of experience in AF ablation suggests that the ability to measure CF may provide additional useful information to the operator. It ensures uniform ablations, with little variability in the catheter manipulations, and it avoids excessive contact forces increasing the patient safety.

  4. ACUTE TERMINATION OF HUMAN ATRIAL FIBRILLATION BY IDENTIFICATION AND CATHETER ABLATION OF LOCALIZED ROTORS AND SOURCES

    PubMed Central

    Shivkumar, Kalyanam; Ellenbogen, Kenneth A.; Hummel, John D.; Miller, John M.; Steinberg, Jonathan S.

    2012-01-01

    Catheter ablation of atrial fibrillation (AF) currently relies on eliminating triggers, and no reliable method exists to map the arrhythmia itself to identify ablation targets. The aim of this multicenter study was to define the use of Focal Impulse and Rotor Modulation (FIRM) for identifying ablation targets. METHODS We prospectively enrolled the first (n=14, 11 males) consecutive patients undergoing FIRM guided ablation for persistent (n=11) and paroxysmal AF at 5 centers. A 64 pole basket catheter was used for panoramic right and left atrial mapping during AF. AF electrograms were analyzed using a novel system to identify sustained rotors (spiral waves), or focal beats (centrifugal activation to surrounding atrium). Ablation was performed first at identified sources. The primary endpoints were acute AF termination or organization (>10 % cycle length prolongation). Conventional ablation was performed only after FIRM guided ablation. RESULTS 12/14 cases were mapped. AF sources were demonstrated in all patients (average of 1.9±0.8 per patient). Sources were left atrial in 18 cases, and right atrial in 5 cases, and 21/23 were rotors. FIRM guided ablation achieved the acute endpoint in all patients, consisting of AF termination in n=8 (4.9±3.9 min at the primary source), and organization in n=4. Total FIRM time for all patients was 12.3±8.6 min. CONCLUSIONS FIRM guided ablation revealed localized AF rotors/focal sources in patients with paroxysmal, persistent and longstanding persistent AF. Brief targeted FIRM guided ablation at a priori identified sites terminated or substantially organized AF in all cases prior to any other ablation. PMID:23130890

  5. Isolation of canine coronary sinus musculature from the atria by radiofrequency catheter ablation prevents induction of atrial fibrillation.

    PubMed

    Morita, Hiroshi; Zipes, Douglas P; Morita, Shiho T; Wu, Jiashin

    2014-12-01

    The junction between the coronary sinus (CS) musculature and both atria contributes to initiation of atrial tachyarrhythmias. The current study investigated the effects of CS isolation from the atria by radiofrequency catheter ablation on the induction and maintenance of atrial fibrillation (AF). Using an optical mapping system, we mapped action potentials at 256 surface sites in 17 isolated and arterially perfused canine atrial tissues containing the entire musculature of the CS, right atrial septum, posterior left atrium, left inferior pulmonary vein, and vein of Marshal. Rapid pacing from each site before and after addition of acetylcholine (0.5 μmol/L) was applied to induce AF. Epicardial radiofrequency catheter ablation at CS-atrial junctions isolated the CS from the atria. Rapid pacing induced sustained AF in all tissues after acetylcholine. Microreentry within the CS drove AF in 88% of preparations. Reentries associated with the vein of Marshall (29%), CS-atrial junctions (53%), right atrium (65%), and pulmonary vein (76%) (frequently with 2-4 simultaneous circuits) were additional drivers of AF. Radiofrequency catheter ablation eliminated AF in 13 tissues before acetylcholine (P<0.01) and in 5 tissues after acetylcholine. Radiofrequency catheter ablation also abbreviated the duration of AF in 12 tissues (P<0.01). CS and its musculature developed unstable reentry and AF, which were prevented by isolation of CS musculature from atrial tissue. The results suggest that CS can be a substrate of recurrent AF in patients after pulmonary vein isolation and that CS isolation might help prevent recurrent AF. © 2014 American Heart Association, Inc.

  6. Radiofrequency catheter ablation of atrial fibrillation: Electrical modification suggesting transmurality is faster achieved with remote magnetic catheter in comparison with contact force use.

    PubMed

    Bun, Sok-Sithikun; Ayari, Anis; Latcu, Decebal Gabriel; Errahmouni, Abdelkarim; Saoudi, Nadir

    2017-07-01

    Remote magnetic navigation (RMN) and contact force (CF) sensing catheters are available technologies for radiofrequency (RF) catheter ablation of atrial fibrillation (AF). Our purpose was to compare time to electrogram (EGM) modification suggesting transmural lesions between RMN and CF-guided AF ablation. A total of 1,008 RF applications were analyzed in 21 patients undergoing RMN (n = 11) or CF-guided ablation (n = 10) for paroxysmal AF. All procedures were performed in sinus rhythm during general anesthesia. Time to EGM modification was measured until transmurality criteria were fulfilled: (1) complete disappearance of R if initial QR morphology; (2) diminution > 75% of R if initial QRS morphology; (3) complete disappearance of R' of initial RSR' morphology. Impedance drop as well as force time integral (FTI) were also assessed for each application. Mean CF at the beginning of each RF application in the CF group was 11 ± 2 g and mean FTI per application was 488 ± 163 gs. Time to EGM modification was significantly shorter in the RMN group (4.52 ± 0.1 seconds vs. 5.6 ± 0.09 seconds; P < 0.00001). There was no significant difference between other procedural parameters. Remote magnetic AF ablation is associated with faster EGM modification suggesting transmurality than optimized CF and FTI-guided catheter ablation. © 2017 Wiley Periodicals, Inc.

  7. Family history of atrial fibrillation as a predictor of atrial substrate and arrhythmia recurrence in patients undergoing atrial fibrillation catheter ablation.

    PubMed

    Kapur, Sunil; Kumar, Saurabh; John, Roy M; Stevenson, William G; Tedrow, Usha B; Koplan, Bruce A; Epstein, Laurence M; MacRae, Calum A; Michaud, Gregory F

    2018-06-01

    A commonly held notion is that patients with a family history of atrial fibrillation (AF) have worse atrial substrate and higher rates of arrhythmia recurrence following ablation. We sought to examine differences in atrial substrate and catheter ablation outcomes in patients with a 1st degree family member with paroxysmal or persistent AF (PeAF) compared to those without. A total of 256 consecutive patients undergoing their 1st ablation for AF (123 paroxysmal, 133 persistent) with >1 year follow up were included. The presence of one 1st-degree family relative was defined as a 'positive family history'. Clinical characteristics, electroanatomic map findings, ablation characteristics and outcomes were compared in patients with and without a positive family history of AF. Patients with paroxysmal fibrillation with a positive family history (n = 57; 46%) had similar clinical characteristics and arrhythmia recurrence after catheter ablation as those without. Of those that recurred, patients with a positive family history were more likely to have progressed to PeAF (P = 0.05). Patients with PeAF with a positive family history (n = 75; 56%) had similar clinical characteristics, electroanatomic mapping findings and ablation characteristics, but worse long term arrhythmia free survival (P = 0.04). The presence of a 1st-degree family member with AF does not impact the clinical outcomes of catheter ablation for paroxysmal AF. However, a positive family history is associated with worse arrhythmia free survival in patients with PeAF. This finding is not explained by differences in clinical characteristics, atrial substrate assessed by voltage maps or ablation characteristics.

  8. Cigarette smoking causes a worse long-term outcome in persistent atrial fibrillation following catheter ablation.

    PubMed

    Cheng, Wen-Han; Lo, Li-Wei; Lin, Yenn-Jiang; Chang, Shih-Lin; Hu, Yu-Feng; Hung, Yuan; Chung, Fa-Po; Chang, Ting-Yung; Huang, Ting-Chung; Yamada, Shinya; Salim, Simon; Te, Abigail Louise D; Liao, Jo-Nan; Tuan, Ta-Chuan; Chao, Tze-Fan; Tsai, Tseng-Ying; Liu, Shin-Huei; Chen, Shih-Ann

    2018-02-09

    Cigarette smoking contributes to the development of atrial fibrosis via nicotine. The impact of smoking on ablation results in persistent atrial fibrillation (AF) is unknown. We aimed to investigate the triggers and long-term outcome between smokers and nonsmokers in the patients with persistent AF after catheter ablation. This study included 201 (177 males, 53 ± 10 years old) patients who received index catheter ablation, including pulmonary vein isolation (PVI) and complex fractionated atrial electrograms (CFAEs) ablation for persistent AF, retrospectively. Electrophysiological characteristics at the index procedure and long-term outcome were investigated to determine the differences between smokers and nonsmokers. Baseline characteristics were similar between two groups. Pulmonary vein (PV) triggers were found in all patients in the two groups. There was a higher incidence of nonpulmonary vein (NPV) triggers in smokers than in nonsmokers (61% vs. 31%, P < 0.05). There were no differences of the long-term ablation outcomes between smokers and nonsmokers in Kaplan-Meier analysis. Smokers with PV plus right atrial NPV (RA-NPV) triggers had a higher incidence of recurrence (log-rank P < 0.05) than those without RA-NPV triggers, but not in nonsmokers, after a mean follow-up of 31 ± 25 months. Smoking increases the incidence of NPV triggers in patients with persistent AF. Smokers who have RA-NPV triggers during index procedure do have a worse outcome after catheter ablation, indicating the harmful effects of nicotine to right atrium. © 2018 Wiley Periodicals, Inc.

  9. Real-time rotational ICE imaging of the relationship of the ablation catheter tip and the esophagus during atrial fibrillation ablation.

    PubMed

    Helms, Adam; West, J Jason; Patel, Amit; Mounsey, J Paul; DiMarco, John P; Mangrum, J Michael; Ferguson, John D

    2009-02-01

    Atrioesophageal fistula is a rare complication of atrial fibrillation (AF) ablation that should be avoided. We investigated whether rotational intracardiac echocardiography (ICE) can help to minimize ablation close to the esophagus. We studied 41 patients referred for catheter ablation of refractory AF. A rotational ICE catheter was inserted into the (LA) to determine the location of the esophagus. The esophagus was identified to be either adjacent to the pulmonary vein (PV) ostium or to a cuff 2 cm outside the ostium. Circumferential ablation was performed at the PV ostium, with the exact ablation location determined by ICE. The relationship of the catheter tip to the esophagus was imaged during energy delivery, allowing interruption when respiration moved the tip closer to the esophagus. Out of 41 patients, the esophagus was seen near left-sided PVs in 32 and near right-sided PVs in three patients. The median distance from LA endocardium to esophagus was 2.2 mm (range, 1.4-6 mm). In 21 of 35 patients with a closely related esophagus, ablation over the esophagus was avoided by ablating either lateral or medial to the esophagus. In 14 patients, the esophagus could not be avoided, and risk was minimized by limiting lesion size. Significant movement (>10 mm) of the esophagus during the procedure occurred in 3/41 cases. Rotational ICE can accurately determine the distance of ablation sites from the esophagus. Real-time imaging of the relationship of the ablation catheter tip to the esophagus may reduce the incidence of esophageal injury.

  10. Efficacy of catheter ablation of atrial fibrillation beyond HATCH score.

    PubMed

    Tang, Ri-Bo; Dong, Jian-Zeng; Long, De-Yong; Yu, Rong-Hui; Ning, Man; Jiang, Chen-Xi; Sang, Cai-Hua; Liu, Xiao-Hui; Ma, Chang-Sheng

    2012-10-01

    HATCH score is an established predictor of progression from paroxysmal to persistent atrial fibrillation (AF). The purpose of this study was to determine if HATCH score could predict recurrence after catheter ablation of AF. The data of 488 consecutive paroxysmal AF patients who underwent an index circumferential pulmonary veins (PV) ablation were retrospectively analyzed. Of these patients, 250 (51.2%) patients had HATCH score = 0, 185 (37.9%) patients had HATCH score = 1, and 53 (10.9%) patients had HATCH score ≥ 2 (28 patients had HATCH score = 2, 23 patients had HATCH score = 3, and 2 patients had HATCH score = 4). The patients with HATCH score ≥ 2 had significantly larger left atrium size, the largest left ventricular end systolic diameter, and the lowest ejection fraction. After a mean follow-up of (823 ± 532) days, the recurrence rates were 36.4%, 37.8% and 28.3% from the HATCH score = 0, HATCH score = 1 to HATCH score ≥ 2 categories (P = 0.498). Univariate analysis revealed that left atrium size, body mass index, and failure of PV isolation were predictors of AF recurrence. After adjustment for body mass index, left atrial size and PV isolation, the HATCH score was not an independent predictor of recurrence (HR = 0.92, 95% confidence interval = 0.76 - 1.12, P = 0.406) in multivariate analysis. HATCH score has no value in prediction of AF recurrence after catheter ablation.

  11. Safety and Long-Term Outcomes of Catheter Ablation of Atrial Fibrillation Using Magnetic Navigation versus Manual Conventional Ablation: A Propensity-Score Analysis.

    PubMed

    Adragão, Pedro Pulido; Cavaco, Diogo; Ferreira, António Miguel; Costa, Francisco Moscoso; Parreira, Leonor; Carmo, Pedro; Morgado, Francisco Bello; Santos, Katya Reis; Santos, Pedro Galvão; Carvalho, Maria Salomé; Durazzo, Anai; Marques, Hugo; Gonçalves, Pedro Araújo; Raposo, Luís; Mendes, Miguel

    2016-03-01

    Whether or not the potential advantages of using a magnetic navigation system (MNS) translate into improved outcomes in patients undergoing atrial fibrillation (AF) ablation is a question that remains unanswered. In this observational registry study, we used propensity-score matching to compare the outcomes of patients with symptomatic drug-refractory AF who underwent catheter ablation using MNS with the outcomes of those who underwent catheter ablation using conventional manual navigation. Among 1,035 eligible patients, 287 patients in each group had similar propensity scores and were included in the analysis. The primary efficacy outcome was the rate of AF relapse after a 3-month blanking period. At a mean follow-up of 2.6 ± 1.5 years, AF ablation with MNS was associated with a similar risk of AF relapse as compared with manual navigation (18.4% per year and 22.3% per year, respectively; hazard ratio 0.81, 95% CI 0.63-1.05; P = 0.108). Major complications occurred in two patients (0.7%) using MNS, and in six patients (2.1%) undergoing manually navigated ablation (P = 0.286). Fluoroscopy times were 21 ± 10 minutes in the manual navigation group, and 12 ± 9 minutes in the MNS group (P < 0.001), whereas total procedure times were 152 ± 52 minutes and 213 ± 58 minutes, respectively (P < 0.001). In this propensity-score matched comparison, magnetic navigation and conventional manual AF ablations seem to have similar relapse rates and a similar risk of complications. AF ablations with magnetic navigation take longer to perform but expose patients to significantly shorter fluoroscopy times. © 2015 Wiley Periodicals, Inc.

  12. Successful Repeat Catheter Ablation of Recurrent Longstanding Persistent Atrial Fibrillation With Rotor Elimination as the Procedural Endpoint: A Case Series.

    PubMed

    Sommer, Philipp; Kircher, Simon; Rolf, Sascha; John, Silke; Arya, Arash; Dinov, Borislav; Richter, Sergio; Bollmann, Andreas; Hindricks, Gerhard

    2016-03-01

    There remains a lack of consensus regarding the ideal ablation strategy for atrial fibrillation (AF), particularly in patients with persistent or longstanding persistent AF. Given increasing evidence from clinical imaging studies that rotors sustain AF, rotor elimination may be a desirable procedural endpoint. However, there is no description to date of the clinical outcomes using rotor elimination during ablation as the procedural endpoint. Moreover, a series of studies question whether procedural AF termination is a desirable endpoint for ablation after many forms of AF ablation. We report a single-center experience of rotor elimination during AF ablation using Focal Impulse and Rotor Mapping (FIRM), describing 20 consecutive patients with case descriptions of 3 patients with recurrent longstanding persistent AF after prior ablation. In all cases, endocardial mapping using a 64-electrode basket catheter was performed to identify rotors, which were eliminated using radiofrequency catheter ablation. After it was verified that all identified rotors were eliminated, standard ablation consisting of PV isolation was performed. Notably, persistent AF terminated in only 1/20 (5%) patients. However, after a follow-up of 6 months, single-procedure freedom from AF was 80% (16/20 patients) with only 1 patient on antiarrhythmic drugs. All three patients in the highlighted series are AF free despite the lack of acute procedural AF termination. Patients with persistent AF including those with unsuccessful prior ablation can be treated successfully by rotor targeted ablation, using the elimination of all rotors rather than acute AF termination as the procedural endpoint. © 2015 Wiley Periodicals, Inc.

  13. Impact of a Novel Catheter Tracking System on Radiation Exposure during the Procedural Phases of Atrial Fibrillation and Flutter Ablation.

    PubMed

    Malliet, Nicolas; Andrade, Jason G; Khairy, Paul; Thanh, Hien Kiem Nguyen; Venier, Sandrine; Dubuc, Marc; Dyrda, Katia; Guerra, Peter; Mondésert, Blandine; Rivard, Léna; Tadros, Rafik; Talajic, Mario; Thibault, Bernard; Roy, Denis; Macle, Laurent

    2015-07-01

    Fluoroscopic guidance is used to position catheters during cardiac ablation. We evaluated the impact of a novel nonfluoroscopic sensor-guided electromagnetic navigation system (MG) on radiation exposure during catheter ablation of atrial fibrillation (AF) or atrial flutter (AFL). A total of 134 consecutive patients referred for ablation of AF (n = 44) or AFL (n = 90) ablation were prospectively enrolled. In one group the MG system was used for nonfluoroscopic catheter positioning, whereas in the conventional group standard fluoroscopy was utilized. Fluoroscopy times were assessed for each stage of procedure and total radiation exposure was quantified. Patient characteristics were similar between the groups. The procedural end point was achieved in all. Median (interquartile range [IQR]) fluoroscopy times were 12.5 minutes (7.6, 17.4) MG group versus 21.5 minutes (15.3, 23.0) conventional group (P < 0.0001) for AF ablation, and 0.8 minutes (0.4, 2.5) MG group versus 9.9 minutes (5.1, 22.5) conventional group (P < 0.0001) for AFL ablation. Median (IQR) total radiation exposure (μGy·m(2)) was 1,107 (906, 2,033) MG group versus 2,835 (1,688, 3,855) conventional group (P = 0.0001) for AF ablation, and 161 (65, 537) MG group versus 1,651 (796, 4,569) conventional group (P < 0.0001) for AFL ablation. No difference in total procedural time was seen. The use of a novel nonfluoroscopic catheter tracking system is associated with a significant reduction in radiation exposure during AF and AFL ablation (61% and 90% reduction, respectively). In the era of heightened awareness of the importance of radiation reduction, this system represents a safe and efficient tool to decrease radiation exposure during electrophysiological ablation procedures. ©2015 Wiley Periodicals, Inc.

  14. Remote magnetic navigation for circumferential pulmonary vein ablation: single-catheter technique or additional use of a circular mapping catheter?

    PubMed

    Vollmann, Dirk; Lüthje, Lars; Seegers, Joachim; Sohns, Christian; Sossalla, Samuel; Sohns, Jan; Röver, Christian; Hasenfuß, Gerd; Zabel, Markus

    2014-10-01

    Remote magnetic navigation (RMN) is utilized for catheter guidance during pulmonary vein ablation (PVA). We aimed to determine whether the additional use of a circular mapping catheter (CMC) influences efficacy and outcome of RMN-guided PVA. A total of 80 consecutive subjects (65 % male, age 62 ± 9 years) underwent circumferential PVA with a 3D mapping system and an RMN-guided irrigated catheter. Procedural endpoint was complete PV isolation (PVI), total radiofrequency (RF) time >60 min, or procedure duration >5 h. PVI was defined as an entrance and/or exit block, diagnosed with a CMC within the PV ostium or by pacing via the roving RMN-guided catheter (single-catheter technique). Prolonged Holter monitoring after 3 and 6 months was used to detect atrial tachyarrhythmia (AT/AF) recurrences. Complete PVI was achieved in 56 % (45/80) of all subjects (isolated PVs per patient, 3.1 ± 1.2; RF time, 56.3 ± 17.2 min; procedure duration, 3.8 ± 0.8 h). Prospective validation of the single-catheter technique for diagnosing PVI demonstrated high concordance (94 %) with blinded CMC results. CMC use in first-time PVA was associated with similar total RF and procedure times but higher PV isolation rate. Upon multivariate analysis, CMC use, female gender, left PV, smaller PV ostium and repeat PVA predicted PVI during RMN-guided ablation. Persistent AF and mitral regurgitation at baseline and the number of non-isolated PVs predicted AT/AF recurrence during follow-up. Concomitant CMC use for first-time, RMN-guided PVA is associated with similar procedure duration but higher PV isolation rates as compared to a single-catheter approach. Since the number of isolated PVs predicts freedom from AT/AF, CMC utilization appears advisable for first-time, RMN-guided PVA.

  15. HATCH score in the prediction of new-onset atrial fibrillation after catheter ablation of typical atrial flutter.

    PubMed

    Chen, Ke; Bai, Rong; Deng, Wenning; Gao, Chuanyu; Zhang, Jing; Wang, Xianqing; Wang, Shunbao; Fu, Haixia; Zhao, Yonghui; Zhang, Jiaying; Dong, Jianzeng; Ma, Changsheng

    2015-07-01

    New-onset atrial fibrillation (AF) is not uncommon after ablation of typical atrial flutter (AFL); however, limited data are available for a risk prediction model for the future occurrence of AF in patients with typical AFL undergoing successful catheter ablation. This study aimed to determine whether the HATCH score (which is based on hypertension, age ≥75 years, transient ischemic attack or stroke, chronic obstructive pulmonary disease, and heart failure) is useful for risk prediction of subsequent AF after ablation of typical AFL. A total of 216 consecutive patients presenting with typical AFL and no history of AF who underwent successful catheter ablation were enrolled in the study. The clinical endpoint was occurrence of new-onset AF during follow-up after ablation. During a follow-up period of 29.1 ± 18.3 months, 85 patients (39%) experienced at least 1 episode of AF. Multivariate Cox regression analysis demonstrated that the HATCH score (hazard ratio 1.784; 95% confidence interval 1.352-2.324; P < .001) and left atrial diameter (hazard ratio 1.270; 95% confidence interval 1.115-1.426; P < .001) were independently associated with new-onset AF after typical AFL ablation. The area under the receiver operator characteristic curve based on the HATCH score for prediction of new-onset AF was 0.743. The HATCH score could be used to stratify the patients into 2 groups with different incidences of new-onset AF (69% vs 27%, P < .001) at a cutoff value of 2. The HATCH score is a useful predictor of new-onset AF after typical AFL ablation. Copyright © 2015 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  16. Comparison of PV signal quality using a novel circular mapping and ablation catheter versus a standard circular mapping catheter.

    PubMed

    von Bary, Christian; Fredersdorf-Hahn, Sabine; Heinicke, Norbert; Jungbauer, Carsten; Schmid, Peter; Riegger, Günter A; Weber, Stefan

    2011-08-01

    Recently, new catheter technologies have been developed for atrial fibrillation (AF) ablation. We investigate the diagnostic accuracy of a circular mapping and pulmonary vein ablation catheter (PVAC) compared with a standard circular mapping catheter (Orbiter) and the influence of filter settings on signal quality. After reconstruction of the left atrium by three-dimensional atriography, baseline PV potentials (PVP) were recorded consecutively with PVAC and Orbiter in 20 patients with paroxysmal AF. PVPs were compared and attributed to predefined anatomical PV segments. Ablation was performed in 80 PVs using the PVAC. If isolation of the PVs was assumed, signal assessment of each PV was repeated with the Orbiter. If residual PV potentials could be uncovered, different filter settings were tested to improve mapping quality of the PVAC. Ablation was continued until complete PV isolation (PVI) was confirmed with the Orbiter. Baseline mapping demonstrated a good correlation between the Orbiter and PVAC. Mapping accuracy using the PVAC for mapping and ablation was 94% (74 of 79 PVs). Additional mapping with the Orbiter improved the PV isolation rate to 99%. Adjustment of filter settings failed to improve quality of the PV signals compared with standard filter settings. Using the PVAC as a stand-alone strategy for mapping and ablation, one should be aware that in some cases, different signal morphology mimics PVI isolation. Adjustment of filter settings failed to improve signal quality. The use of an additional mapping catheter is recommended to become familiar with the particular signal morphology during the first PVAC cases or whenever there is a doubt about successful isolation of the pulmonary veins.

  17. Robotic assistance and general anaesthesia improve catheter stability and increase signal attenuation during atrial fibrillation ablation.

    PubMed

    Malcolme-Lawes, Louisa C; Lim, Phang Boon; Koa-Wing, Michael; Whinnett, Zachary I; Jamil-Copley, Shahnaz; Hayat, Sajad; Francis, Darrel P; Kojodjojo, Pipin; Davies, D Wyn; Peters, Nicholas S; Kanagaratnam, Prapa

    2013-01-01

    Recurrent arrhythmias after ablation procedures are often caused by recovery of ablated tissue. Robotic catheter manipulation systems increase catheter tip stability which improves energy delivery and could produce more transmural lesions. We tested this assertion using bipolar voltage attenuation as a marker of lesion quality comparing robotic and manual circumferential pulmonary vein ablation for atrial fibrillation (AF). Twenty patients were randomly assigned to robotic or manual AF ablation at standard radiofrequency (RF) settings for our institution (30 W 60 s manual, 25 W 30 s robotic, R30). A separate group of 10 consecutive patients underwent robotic ablation at increased RF duration, 25 W for 60 s (R60). Lesions were marked on an electroanatomic map before and after ablation to measure distance moved and change in bipolar electrogram amplitude during RF. A total of 1108 lesions were studied (761 robotic, 347 manual). A correlation was identified between voltage attenuation and catheter movement during RF (Spearman's rho -0.929, P < 0.001). The ablation catheter was more stable during robotic RF; 2.9 ± 2.3 mm (R30) and 2.6 ± 2.2 mm (R60), both significantly less than the manual group (4.3 ± 3.0 mm, P < 0.001). Despite improved stability, there was no difference in signal attenuation between the manual and R30 group. However, there was increased signal attenuation in the R60 group (52.4 ± 19.4%) compared with manual (47.7 ± 25.4%, P = 0.01). When procedures under general anaesthesia (GA) and conscious sedation were analysed separately, the improvement in signal attenuation in the R60 group was only significant in the procedures under GA. Robotically assisted ablation has the capability to deliver greater bipolar voltage attenuation compared with manual ablation with appropriate selection of RF parameters. General anaesthesia confers additional benefits of catheter stability and greater signal attenuation. These findings may have a significant impact on

  18. Decrease in B-Type Natriuretic Peptide Levels and Successful Catheter Ablation for Atrial Fibrillation in Patients with Heart Failure.

    PubMed

    Yanagisawa, Satoshi; Inden, Yasuya; Kato, Hiroyuki; Fujii, Aya; Mizutani, Yoshiaki; Ito, Tadahiro; Kamikubo, Yosuke; Kanzaki, Yasunori; Hirai, Makoto; Murohara, Toyoaki

    2016-03-01

    Little is known about the association between B-type natriuretic peptide (BNP) levels and catheter ablation of atrial fibrillation (AF) in patients with heart failure. This study aimed to examine the impact of elimination of AF by catheter ablation on BNP levels in patients with left ventricular systolic dysfunction. Fifty-four AF patients with left ventricular ejection fraction (LVEF) ≤ 50%, who underwent radiofrequency catheter ablation therapy of AF, were included. BNP sampling was performed at baseline, 3 days, and 1 month after ablation. After a follow-up period of 6 months, the BNP levels decreased significantly in the nonrecurrence group (n = 35; median 126.3 [interquartile 57.2-206.5] pg/mL, 63.5 [23.9-180.2] pg/mL, and 45.9 [21.9-160.3] pg/mL, P < 0.001, respectively), but not in the recurrence group (n = 19; 144.7 [87.1-217.3] pg/mL, 88.8 [12.9-213.2] pg/mL, and 118.5 [51.6-298.2] pg/mL, P = 0.368, respectively). The patients in the nonrecurrence group had a higher percentage relative reduction in BNP levels from baseline to 1 month after ablation than those in the recurrence group (56.5 [-9.0-77.4]% vs -2.4 [-47.1-60.9]%, P = 0.027). Additionally, a relative reduction in BNP levels significantly correlated with an increase in LVEF after ablation (r = 0.486, P < 0.001). Plasma BNP levels decreased significantly with successful catheter ablation of AF in patients with impaired LVEF. The decrease in BNP levels might be associated with early recovery of cardiac function and subsequent maintenance of sinus rhythm at follow-up. ©2015 Wiley Periodicals, Inc.

  19. Long‐term Outcomes of Catheter Ablation of Atrial Fibrillation: A Systematic Review and Meta‐analysis

    PubMed Central

    Ganesan, Anand N.; Shipp, Nicholas J.; Brooks, Anthony G.; Kuklik, Pawel; Lau, Dennis H.; Lim, Han S.; Sullivan, Thomas; Roberts‐Thomson, Kurt C.; Sanders, Prashanthan

    2013-01-01

    Background In the past decade, catheter ablation has become an established therapy for symptomatic atrial fibrillation (AF). Until very recently, few data have been available to guide the clinical community on the outcomes of AF ablation at ≥3 years of follow‐up. We aimed to systematically review the medical literature to evaluate the long‐term outcomes of AF ablation. Methods and Results A structured electronic database search (PubMed, Embase, Web of Science, Cochrane) of the scientific literature was performed for studies describing outcomes at ≥3 years after AF ablation, with a mean follow‐up of ≥24 months after the index procedure. The following data were extracted: (1) single‐procedure success, (2) multiple‐procedure success, and (3) requirement for repeat procedures. Data were extracted from 19 studies, including 6167 patients undergoing AF ablation. Single‐procedure freedom from atrial arrhythmia at long‐term follow‐up was 53.1% (95% CI 46.2% to 60.0%) overall, 54.1% (95% CI 44.4% to 63.4%) in paroxysmal AF, and 41.8% (95% CI 25.2% to 60.5%) in nonparoxysmal AF. Substantial heterogeneity (I2>50%) was noted for single‐procedure outcomes. With multiple procedures, the long‐term success rate was 79.8% (95% CI 75.0% to 83.8%) overall, with significant heterogeneity (I2>50%).The average number of procedures per patient was 1.51 (95% CI 1.36 to 1.67). Conclusions Catheter ablation is an effective and durable long‐term therapeutic strategy for some AF patients. Although significant heterogeneity is seen with single procedures, long‐term freedom from atrial arrhythmia can be achieved in some patients, but multiple procedures may be required. PMID:23537812

  20. How to perform posterior wall isolation in catheter ablation for atrial fibrillation.

    PubMed

    Sugumar, Hariharan; Thomas, Stuart P; Prabhu, Sandeep; Voskoboinik, Aleksandr; Kistler, Peter M

    2018-02-01

    Catheter ablation has become standard of care in patients with symptomatic atrial fibrillation (AF). Although there have been significant advances in our understanding and technology, a substantial proportion of patients have ongoing AF requiring repeat procedures. Pulmonary vein isolation (PVI) is the cornerstone of AF ablation; however, it is less effective in patients with persistent as opposed to paroxysmal atrial fibrillation. Left atrial posterior wall isolation (PWI) is commonly performed as an adjunct to PVI in patients with persistent AF with nonrandomized studies showing improved outcomes. Anatomical considerations and detailed outline of the various approaches and techniques to performing PWI are detailed, and advantages and pitfalls to assist the clinical electrophysiologist successfully and safely complete PWI are described. © 2017 Wiley Periodicals, Inc.

  1. Initial experience of a novel mapping system combined with remote magnetic navigation in the catheter ablation of atrial fibrillation.

    PubMed

    Lin, Changjian; Pehrson, Steen; Jacobsen, Peter Karl; Chen, Xu

    2017-12-01

    There have been advancements of sophisticated mapping systems used for ablation procedures over the last decade. Utilization of these novel mapping systems in combination with remote magnetic navigation (RMN) needs to be established. We investigated the new EnSite Precision mapping system (St. Jude Medical, Inc., St. Paul, MN, USA), which collects magnetic data for checking navigation field stability and is built on an open platform, allowing physicians to choose diagnostic and ablation catheters. We address its compatibility with RMN. To assess the clinical utility of a novel 3D mapping system (EnSite Precision mapping system) combined with RMN (Niobe ES, Stereotaxis, Inc., St. Louis, MO, USA) for atrial fibrillation (AF) ablation. In this prospective nonrandomized study, two groups of patients were treated in our center for drug refractory AF. Patients were consecutively enrolled in each group. Group A (n = 35, 14 persistent AF [PsAF]) was treated using the novel 3D mapping system combined with RMN. Group B (n = 38, 16 PsAF) was treated using Carto ® 3 (Biosense Webster, Inc., Diamond Bar, CA, USA) combined with RMN. In Group A, the left atrium (LA) was mapped with a circular magnetic catheter manually and was then replaced by a RMN ablation catheter. At the end of the procedures in Group A, the circular catheter was used for confirming field stability. In Group B, an ablation catheter was controlled by RMN to perform both LA mapping and ablation. All patients underwent pulmonary vein antrum isolation. Additional complex fractionated atrial electrograms (CFAEs) ablation was performed for PsAF. Procedural, ablation, and fluoroscopy times were recorded and complications were assessed. Electrophysiological end points were achieved in all patients. Using the novel mapping system, LA mapping time was fast (308 ± 60 seconds) with detailed anatomy points (178,831 ± 70,897) collected and magnetic points throughout LA. At the end of the procedures in Group A, the

  2. Robust tracking of a virtual electrode on a coronary sinus catheter for atrial fibrillation ablation procedures

    NASA Astrophysics Data System (ADS)

    Wu, Wen; Chen, Terrence; Strobel, Norbert; Comaniciu, Dorin

    2012-02-01

    Catheter tracking in X-ray fluoroscopic images has become more important in interventional applications for atrial fibrillation (AF) ablation procedures. It provides real-time guidance for the physicians and can be used as reference for motion compensation applications. In this paper, we propose a novel approach to track a virtual electrode (VE), which is a non-existing electrode on the coronary sinus (CS) catheter at a more proximal location than any real electrodes. Successful tracking of the VE can provide more accurate motion information than tracking of real electrodes. To achieve VE tracking, we first model the CS catheter as a set of electrodes which are detected by our previously published learning-based approach.1 The tracked electrodes are then used to generate the hypotheses for tracking the VE. Model-based hypotheses are fused and evaluated by a Bayesian framework. Evaluation has been conducted on a database of clinical AF ablation data including challenging scenarios such as low signal-to-noise ratio (SNR), occlusion and nonrigid deformation. Our approach obtains 0.54mm median error and 90% of evaluated data have errors less than 1.67mm. The speed of our tracking algorithm reaches 6 frames-per-second on most data. Our study on motion compensation shows that using the VE as reference provides a good point to detect non-physiological catheter motion during the AF ablation procedures.2

  3. Outcomes after cardioversion and atrial fibrillation ablation in patients treated with rivaroxaban and warfarin in the ROCKET AF trial.

    PubMed

    Piccini, Jonathan P; Stevens, Susanna R; Lokhnygina, Yuliya; Patel, Manesh R; Halperin, Jonathan L; Singer, Daniel E; Hankey, Graeme J; Hacke, Werner; Becker, Richard C; Nessel, Christopher C; Mahaffey, Kenneth W; Fox, Keith A A; Califf, Robert M; Breithardt, Günter

    2013-05-14

    This study sought to investigate the outcomes following cardioversion or catheter ablation in patients with atrial fibrillation (AF) treated with warfarin or rivaroxaban. There are limited data on outcomes following cardioversion or catheter ablation in AF patients treated with factor Xa inhibitors. We compared the incidence of electrical cardioversion (ECV), pharmacologic cardioversion (PCV), or AF ablation and subsequent outcomes in patients in a post hoc analysis of the ROCKET AF (Efficacy and Safety Study of Rivaroxaban With Warfarin for the Prevention of Stroke and Non-Central Nervous System Systemic Embolism in Patients With Non-Valvular Atrial Fibrillation) trial. Over a median follow-up of 2.1 years, 143 patients underwent ECV, 142 underwent PCV, and 79 underwent catheter ablation. The overall incidence of ECV, PCV, or AF ablation was 1.45 per 100 patient-years (n = 321; 1.44 [n = 161] in the warfarin arm, 1.46 [n = 160] in the rivaroxaban arm). The crude rates of stroke and death increased in the first 30 days after cardioversion or ablation. After adjustment for baseline differences, the long-term incidence of stroke or systemic embolism (hazard ratio [HR]: 1.38; 95% confidence interval [CI]: 0.61 to 3.11), cardiovascular death (HR: 1.57; 95% CI: 0.69 to 3.55), and death from all causes (HR: 1.75; 95% CI: 0.90 to 3.42) were not different before and after cardioversion or AF ablation. Hospitalization increased after cardioversion or AF ablation (HR: 2.01; 95% CI: 1.51 to 2.68), but there was no evidence of a differential effect by randomized treatment (p value for interaction = 0.58). The incidence of stroke or systemic embolism (1.88% vs. 1.86%) and death (1.88% vs. 3.73%) were similar in the rivaroxaban-treated and warfarin-treated groups. Despite an increase in hospitalization, there were no differences in long-term stroke rates or survival following cardioversion or AF ablation. Outcomes were similar in patients treated with rivaroxaban or warfarin

  4. Ablation for Atrial Fibrillation

    PubMed Central

    2006-01-01

    Executive Summary Objective To review the effectiveness, safety, and costing of ablation methods to manage atrial fibrillation (AF). The ablation methods reviewed were catheter ablation and surgical ablation. Clinical Need Atrial fibrillation is characterized by an irregular, usually rapid, heart rate that limits the ability of the atria to pump blood effectively to the ventricles. Atrial fibrillation can be a primary diagnosis or it may be associated with other diseases, such as high blood pressure, abnormal heart muscle function, chronic lung diseases, and coronary heart disease. The most common symptom of AF is palpitations. Symptoms caused by decreased blood flow include dizziness, fatigue, and shortness of breath. Some patients with AF do not experience any symptoms. According to United States data, the incidence of AF increases with age, with a prevalence of 1 per 200 people aged between 50 and 60 years, and 1 per 10 people aged over 80 years. In 2004, the Institute for Clinical Evaluative Sciences (ICES) estimated that the rate of hospitalization for AF in Canada was 582.7 per 100,000 population. They also reported that of the patients discharged alive, 2.7% were readmitted within 1 year for stroke. One United States prevalence study of AF indicated that the overall prevalence of AF was 0.95%. When the results of this study were extrapolated to the population of Ontario, the prevalence of AF in Ontario is 98,758 for residents aged over 20 years. Currently, the first-line therapy for AF is medical therapy with antiarrhythmic drugs (AADs). There are several AADs available, because there is no one AAD that is effective for all patients. The AADs have critical adverse effects that can aggravate existing arrhythmias. The drug selection process frequently involves trial and error until the patient’s symptoms subside. The Technology Ablation has been frequently described as a “cure” for AF, compared with drug therapy, which controls AF but does not cure it

  5. Outcomes of atrioesophageal fistula following catheter ablation of atrial fibrillation treated with surgical repair versus esophageal stenting.

    PubMed

    Mohanty, Sanghamitra; Santangeli, Pasquale; Mohanty, Prasant; Di Biase, Luigi; Trivedi, Chintan; Bai, Rong; Horton, Rodney; Burkhardt, J David; Sanchez, Javier E; Zagrodzky, Jason; Bailey, Shane; Gallinghouse, Joseph G; Hranitzky, Patrick M; Sun, Albert Y; Hongo, Richard; Beheiry, Salwa; Natale, Andrea

    2014-06-01

    Atrioesophageal fistula (AEF) is a rare but devastating complication of radiofrequency catheter ablation (RFCA) of atrial fibrillation (AF). Surgical repair and esophageal stents are available treatment options for AEF. We report outcomes of these 2 management strategies. Nine patients with AEF post-RFCA for AF were included in this study. AEF was diagnosed based on symptoms and chest CT imaging. Of the 9 patients, 5 received stents and 4 underwent surgical repair of fistula. AF ablation was performed under general anesthesia (n = 4) or conscious sedation (n = 5). During ablation, RF power was maintained between 25 and 35 Watts in areas close to the esophagus and energy delivery discontinued when esophageal temperature reached 38 °C. Seven patients underwent ablation with 3.5-mm open-irrigated catheter, 1 with 8-mm nonirrigated catheter, and 1 had surgical epicardial ablation. Seven patients received proton pump inhibitor and sucralfate before and after procedure. AEF symptoms developed within 2–6 weeks from ablation. Esophageal stenting was performed in 5 patients (median age 58 years, median time from RFCA 4 weeks) and 4 underwent surgical repair (median age 54 years, median time from RFCA 4 weeks) within 2–4 hours from diagnosis. All 5 patients receiving stents died within 1 week of the procedure due to cerebral embolism, septic shock, or respiratory failure. On the other hand, the 4 patients that received surgical repair were alive at median follow-up of 2.1 years (P = 0.005). Esophageal stenting should be discouraged and prompt surgical repair is crucial for survival in patients with atrioesophageal fistula.

  6. Feasibility of zero or near zero fluoroscopy during catheter ablation procedures.

    PubMed

    Haegeli, Laurent M; Stutz, Linda; Mohsen, Mohammed; Wolber, Thomas; Brunckhorst, Corinna; On, Chol-Jun; Duru, Firat

    2018-04-03

    Awareness of risks associated with radiation exposure to patients and medical staff has significantly increased. It has been reported before that the use of advanced three-dimensional electro-anatomical mapping (EAM) system significantly reduces fluoroscopy time, however this study aimed for zero or near zero fluoroscopy ablation to assess its feasibility and safety in ablation of atrial fibrillation (AF) and other tachyarrhythmias in a "real world" experience of a single tertiary care center. This was a single-center study where ablation procedures were attempted without fluoroscopy in 34 consecutive patients with different tachyarrhythmias under the support of EAM system. When transseptal puncture (TSP) was needed, it was attempted under the guidance of intracardiac echocardiography (ICE). Among 34 patients consecutively enrolled in this study, 28 (82.4%) patients were referred for radiofrequency ablation (RFA) of AF, 3 (8.8%) patients for ablation of right ventricular outflow tract (RVOT) ventricular extrasystole (VES), 1 (2.9%) patient for ablation of atrioventricular nodal reentry tachycardia (AVNRT), 2 (5.9%) patients for typical atrial flutter ablation. In 21 (62%) patients the entire procedure was carried out without the use of fluoroscopy. Among 28 AF patients, 15 (54%) patients underwent ablation without the use of fluoroscopy and among these 15 patients, 10 (67%) patients required TSP under ICE guidance while 5 (33%) patients the catheters were introduced to left atrium through a patent foramen ovale. In 13 AF patients, fluoroscopy was only required for double TSP. The total procedure time of AF ablation was 130 ± 50 min. All patients referred for atrial flutter, AVNRT, and VES of the RVOT ablation did not require any fluoroscopy. This study demonstrates the feasibility of zero or near zero fluoroscopy procedure including TSP with the support of EAM and ICE guidance in a "real world" experience of a single tertiary care center. When fluoroscopy was

  7. Catheter ablation of atrial fibrillation in patients with heart failure and preserved ejection fraction.

    PubMed

    Black-Maier, Eric; Ren, Xinru; Steinberg, Benjamin A; Green, Cynthia L; Barnett, Adam S; Rosa, Normita Sta; Al-Khatib, Sana M; Atwater, Brett D; Daubert, James P; Frazier-Mills, Camille; Grant, Augustus O; Hegland, Donald D; Jackson, Kevin P; Jackson, Larry R; Koontz, Jason I; Lewis, Robert K; Sun, Albert Y; Thomas, Kevin L; Bahnson, Tristam D; Piccini, Jonathan P

    2018-05-01

    Few studies have examined outcomes of catheter ablation for atrial fibrillation (AF) in patients with heart failure (HF) with preserved ejection fraction (HFpEF). The purpose of this study was to compare outcomes of AF ablation in patients with HFpEF vs HF with reduced ejection fraction (HFrEF). We performed a retrospective study of 230 patients with HF who underwent AF ablation, including 97 (42.2%) with HFrEF and 133 (57.8%) with HFpEF. Outcomes included adverse events, symptoms (Mayo AF Symptom Inventory [MAFSI]), New York Heart Association (NYHA) functional class, and freedom from recurrent atrial arrhythmia at 12 months. Overall, 150 of 230 patients had nonparoxysmal AF (62.8% HFpEF vs 63.0% HFrEF). Patients with HFpEF had a smaller mean left atrial diameter (4.4 ± 0.8 cm vs 4.7 ± 0.7 cm; P = .013) and were less likely to be taking a beta-blocker at baseline (72.9% vs 85.6%; P = .022). Median (Q1, Q3) procedure times (233 minutes [192, 290] vs 233.5 minutes [193.0, 297.5]; P = .780) and adverse events such as acute HF (3.8% vs 6.2%; P = .395) were similar between HFpEF and HFrEF patients. Freedom from recurrent atrial arrhythmia was not significantly different in HFpEF vs HFrEF patients (33.9% vs 32.6%; adjusted hazard ratio 1.47; 95% confidence interval 0.72-3.01), with similar improvements in NYHA functional class (-0.32 vs -0.19; P = .135) and MAFSI symptom severity (-0.23 vs -0.09; P = .116) after ablation. Catheter ablation of AF seems to have similar effectiveness in patients with HF, regardless of presence of systolic dysfunction. There were no significant differences in procedural characteristics, arrhythmia-free recurrence, or functional improvements between patients with HFpEF and those with HFrEF. Copyright © 2017 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  8. Effect of left atrial volume and pulmonary vein anatomy on outcome of nMARQ™ catheter ablation of paroxysmal atrial fibrillation.

    PubMed

    Stabile, Giuseppe; Anselmino, Matteo; Soldati, Ezio; De Ruvo, Ermengildo; Solimene, Francesco; Iuliano, Assunta; Sciarra, Luigi; Bongiorni, Maria Grazia; Calò, Leonardo; Gaita, Fiorenzo

    2017-03-01

    Left atrial volume (LA) and pulmonary vein (PV) anatomy may potentially relate to technical challenges in achieving stable and effective catheter position in case of atrial fibrillation (AF) ablation by means of "one-shot" catheters. The aim of this study was to investigate whether LA volume and PV anatomy, evaluated by computed tomography (CT) or magnetic resonance (MR) prior to ablation, predict acute and midterm outcome of AF ablation by nMARQ™. We included 75 patients (mean age 58 ± 11 years, 67 % male) with symptomatic paroxysmal AF. All patients underwent CT/MR scanning prior to catheter ablation to evaluate LA volume and PV anatomy. All the patients underwent PV isolation by nMARQ™, an open-irrigated mapping and radiofrequency (RF) decapolar ablation catheter. Ablation was guided by electroanatomic mapping allowing RF energy delivery in the antral region of PVs from ten irrigated electrodes simultaneously. Mean LA volume was 75 ± 40 ml. A normal anatomy (4 PVs) was documented in 40 (53 %) patients and abnormal anatomy (common truncus or accessory PVs) in 35 patients. Mean procedural and fluoroscopy times were 94 ± 55 and 8 ± 5 min, respectively, without significant differences among patients with normal or abnormal anatomy (92 ± 45 vs 95 ± 64 min, p = 0.85 and 6 ± 3 vs 8 ± 4 min, p = 0.65, respectively). Mean ablation time was 14 ± 3 min, and 99 % of the targeted veins were isolated with a mean of 23 ± 5 RF pulses per patient. After a mean follow-up of 17 ± 8 months, 23 (31 %) patients had an atrial arrhythmia recurrence. Neither LA volume nor PV anatomy was a predictor of outcome. LA volume and PV anatomy did not affect procedural data and outcome in patients who underwent PV isolation by an open-irrigated mapping and RF decapolar ablation catheter.

  9. Atrial fibrillation ablation using cryoballoon technology: Recent advances and practical techniques.

    PubMed

    Chen, Shaojie; Schmidt, Boris; Bordignon, Stefano; Bologna, Fabrizio; Perrotta, Laura; Nagase, Takahiko; Chun, K R Julian

    2018-04-16

    Atrial fibrillation (AF) affects 1-2% of the population, and its prevalence is estimated to double in the next 50 years as the population ages. AF results in impaired patients' life quality, deteriorated cardiac function, and even increased mortality. Antiarrhythmic drugs frequently fail to restore sinus rhythm. Catheter ablation is a valuable treatment approach for AF, even as a first-line therapy strategy in selected patients. Effective electrical pulmonary vein isolation (PVI) is the cornerstone of all AF ablation strategies. Use of radiofrequency (RF) catheter in combination of a three-dimensional electroanatomical mapping system is the most established ablation approach. However, catheter ablation of AF is challenging even sometimes for experienced operators. To facilitate catheter ablation of AF without compromising the durability of the pulmonary vein isolation, "single shot" ablation devices have been developed; of them, cryoballoon ablation, is by far the most widely investigated. In this report, we review the current knowledge of AF and discuss the recent evidence in catheter ablation of AF, particularly cryoballoon ablation. Moreover, we review relevant data from the literature as well as our own experience and summarize the key procedural practical techniques in PVI using cryoballoon technology, aiming to shorten the learning curve of the ablation technique and to contribute further to reduction of the disease burden. © 2018 Wiley Periodicals, Inc.

  10. Clinical impact of an open-irrigated radiofrequency catheter with direct force measurement on atrial fibrillation ablation.

    PubMed

    Martinek, Martin; Lemes, Christine; Sigmund, Elisabeth; Derndorfer, Michael; Aichinger, Josef; Winter, Siegmund; Nesser, Hans-Joachim; Pürerfellner, Helmut

    2012-11-01

    Electrode-tissue contact is crucial for adequate lesion formation in radiofrequency catheter ablation (RFCA). We assessed the impact of direct catheter force measurement on acute procedural parameters during RFCA of atrial fibrillation (AF). Fifty consecutive patients (28 male) with paroxysmal AF who underwent their first procedure of circumferential pulmonary vein (PV) isolation (PVI) were assigned to either RFCA using (1) a standard 3.5-mm open-irrigated-tip catheter or (2) a catheter with contact force measurement capabilities. Using the endpoint of PVI with entry and exit block, acute procedural parameters were assessed. Procedural data showed a remarkable decline in ablation time (radiofrequency time needed for PVI) from 50.5 ± 15.9 to 39.0 ± 11.0 minutes (P = 0.007) with a reduction in overall procedure duration from 185 ± 46 to 154 ± 39 minutes (P = 0.022). In parallel, the total energy delivered could be significantly reduced from 70,926 ± 19,470 to 58,511 ± 14,655 Ws (P = 0.019). The number of acute PV reconnections declined from 36% to 12% (P = 0.095). The use of contact force sensing technology is able to significantly reduce ablation and procedure times in PVI. In addition, energy delivery is substantially reduced by avoiding radiofrequency ablation in positions with insufficient surface contact. Procedural efficacy and safety of this new feature have to be evaluated in larger cohorts. ©2012, The Authors. Journal compilation ©2012 Wiley Periodicals, Inc.

  11. Remote magnetic navigation with irrigated tip catheter for ablation of paroxysmal atrial fibrillation.

    PubMed

    Miyazaki, Shinsuke; Shah, Ashok J; Xhaët, Olivier; Derval, Nicolas; Matsuo, Seiichiro; Wright, Matthew; Nault, Isabelle; Forclaz, Andrei; Jadidi, Amir S; Knecht, Sébastien; Rivard, Lena; Liu, Xingpeng; Linton, Nick; Sacher, Frédéric; Hocini, Mélèze; Jaïs, Pierre; Haïssaguerre, Michel

    2010-12-01

    The remote magnetic navigation system (MNS) has been used with a nonirrigated magnetic catheter for atrial fibrillation (AF) ablation. The objective of this study was to evaluate the feasibility and efficiency of the newly available irrigated tip magnetic catheter for index pulmonary vein isolation (PVI) in patients with paroxysmal AF (PAF). Between January 2008 and June 2009, 30 consecutive patients with drug-resistant PAF underwent circular mapping catheter-guided PVI with MNS (MNS group). The outcomes were compared retrospectively with those of a conventional hand-controlled ablation technique during the same period in 44 consecutive patients (manual group). All 4 pulmonary veins were successfully isolated in both groups except in 4 patients in the MNS group. Radiofrequency and procedure duration were higher in the MNS group (60 ± 27 versus 43 ± 16 minutes; P = 0.0019) than in the manual group (246 ± 50 versus 153 ± 51 minutes; P < 0.0001). In the patients who underwent only PVI, total fluoroscopic time also was longer in the MNS group than in the manual group (58 ± 24 versus 40 ± 14 minutes; P = 0.0002). At 12-month follow-up after a single procedure, 69.0% of the patients in MNS group and 61.8% of patients in manual group were free of atrial tachyarrhythmia without antiarrhythmic drugs. There was no significant difference in the atrial tachyarrhythmia-free survival between the 2 groups (P = 0.961). Cardiac tamponade occurred in 1 patient in the manual group. In patients with PAF, MNS-guided PVI with the newly available irrigated tip magnetic catheter backed up with manual ablation whenever required is feasible. However, it requires longer ablation, fluoroscopy, and procedural times than the conventional approach in the early experience stage.

  12. Atrial fibrillation ablation: "perpetual motion" of open irrigated tip catheters at 50 W is safe and improves outcomes.

    PubMed

    Winkle, Roger A; Mead, R Hardwin; Engel, Gregory; Patrawala, Rob A

    2011-05-01

    Point-by-point use of open irrigated tip catheters (OITCs) at 50 W increases atrial fibrillation (AF) ablation cure rates but also increases complications. We determined if constantly moving the OITC (perpetual motion) when using 50 W increases ablation cure rates without increasing complications. We evaluated procedural data, complications, and individual procedure cure rates (IPCRs) for AF ablation using closed tip catheters (CTC) versus OITC at 40, 45, and 50 W in 1,122 ablations. We used "perpetual motion" to move the OITC at 50 W every 3-10 seconds. The OITC showed higher IPCR than CTC at 45 W (P = 0.012) and 50 W (P < 0.0005). For the OITC, IPCR increased from 44.6% to 60.7% as power increased from 40 to 50 W (P = 0.008). The OITC appeared superior to the CTC for all types of AF. For paroxysmal AF, increasing OITC power from 40 to 50 W provided no increase in IPCR (70.6% vs 71.2%, P = 0.827). For persistent AF, increasing power from 40 to 50 W increased IPCR from 34.5% to 59.5% (P = 0.001). Complications were similar for the CTC and the OITC at any power. The OITC at 50 W had shorter procedure, left atrial, and fluoroscopy times (P < 0.0005). Increasing OITC power from 40 to 50 W increases IPCR with no increase in complications as long as the 50 W setting is done using "perpetual motion." The OITC 50 W power setting results in shorter procedure and fluoroscopy times and should be considered for AF ablations. ©2010, The Authors. Journal compilation ©2010 Wiley Periodicals, Inc.

  13. Noninvasive evaluation of reverse atrial remodeling after catheter ablation of atrial fibrillation by P wave dispersion.

    PubMed

    Fujimoto, Yuhi; Yodogawa, Kenji; Takahashi, Kenta; Tsuboi, Ippei; Hayashi, Hiroshi; Uetake, Shunsuke; Iwasaki, Yu-Ki; Hayashi, Meiso; Miyauchi, Yasushi; Shimizu, Wataru

    2017-11-01

    Atrial fibrillation (AF) itself creates structural and electrophysiological changes such as atrial enlargement, shortening of refractory period and decrease in conduction velocity, called "atrial remodeling", promoting its persistence. Although the remodeling process is considered to be reversible, it has not been elucidated in detail. The aim of this study was to assess the feasibility of P wave dispersion in the assessment of reverse atrial remodeling following catheter ablation of AF. Consecutive 126 patients (88 males, age 63.0 ± 10.4 years) who underwent catheter ablation for paroxysmal AF were investigated. P wave dispersion was calculated from the 12 lead ECG before, 1 day, 1 month, 3 months and 6 months after the procedure. Left atrial diameter (LAD), left atrial volume index (LAVI), left ventricular ejection fraction (LVEF), transmitral flow velocity waveform (E/A), and tissue Doppler (E/e') on echocardiography, plasma B-type natriuretic peptide (BNP) concentrations, serum creatinine, and estimated glomerular filtration rate (eGFR) were also measured. Of all patients, 103 subjects remained free of AF for 1 year follow-up. In these patients, P wave dispersion was not changed 1 day and 1 month after the procedure. However, it was significantly decreased at 3 and 6 months (50.1 ± 14.8 to 45.4 ± 14.4 ms, p < 0.05, 45.2 ± 9.9 ms, p < 0.05, respectively). Plasma BNP concentrations, LAD and LAVI were decreased (81.1 ± 103.8 to 44.8 ± 38.3 pg/mL, p < 0.05, 38.2 ± 5.7 to 35.9 ± 5.6 mm, p < 0.05, 33.3 ± 14.2 to 29.3 ± 12.3 mL/m 2 , p < 0.05) at 6 months after the procedure. There were no significant changes in LVEF, E/A, E/e', serum creatinine, and eGFR during the follow up period. P wave dispersion was decreased at 3 and 6 months after catheter ablation in patients without recurrence of AF. P wave dispersion is useful for assessment of reverse remodeling after catheter ablation of AF.

  14. Optimizing radiofrequency ablation of paroxysmal and persistent atrial fibrillation by direct catheter force measurement-a case-matched comparison in 198 patients.

    PubMed

    Sigmund, Elisabeth; Puererfellner, Helmut; Derndorfer, Michael; Kollias, Georgios; Winter, Siegmund; Aichinger, Josef; Nesser, Hans-Joachim; Martinek, Martin

    2015-02-01

    Sufficient electrode-tissue contact is crucial for adequate lesion formation in radiofrequency catheter ablation (RFCA). We assessed the impact of direct catheter force measurement on acute procedural parameters and outcome of RFCA for paroxysmal and persistent atrial fibrillation (AF). Ninety-nine consecutive patients (70% men) with paroxysmal (63.6%) or persistent AF underwent left atrial RFCA using a 3.5-mm open-irrigated-tip (OIT) catheter with contact force measurement capabilities (group 1). For comparison a case-matched cohort with standard OIT catheters was used (99 patients; group 2). Case matching included gender, type of AF, number or RFCA procedures, and type of procedure. Procedural data showed a significant decline in radiofrequency ablation time from 52 ± 20 to 44 ± 16 minutes (P = 0.003) with a remarkable mean reduction in overall procedure time of 34 minutes (P = 0.0001; 225.8 ± 53.1 vs 191.9 ± 53.3 minutes). In parallel, the total fluoroscopy time could be significantly reduced from 28.5 ± 11.0 to 19.9 ± 9.3 minutes (P = 0.0001) as well as fluoroscopy dose from 74.1 ± 58.0 to 56.7 ± 38.9 Gy/cm(2) (P = 0.016). Periprocedural complications were similar in both groups. The use of contact force sensing technology is able to significantly reduce ablation, procedure, and fluoroscopy times as well as dose in RFCA of AF in a mixed case-matched group of paroxysmal and persistent AF. Energy delivery is substantially reduced by avoiding radiofrequency ablation in positions with insufficient surface contact. Additionally 12-month outcome data showed increased efficacy. Such time saving and equally safe technology may have a relevant impact on laboratory management and increased cost effectiveness. © 2014 Wiley Periodicals, Inc.

  15. State-of-the-art and emerging technologies for atrial fibrillation ablation.

    PubMed

    Dewire, Jane; Calkins, Hugh

    2010-03-01

    Catheter ablation is an important treatment modality for patients with atrial fibrillation (AF). Although the superiority of catheter ablation over antiarrhythmic drug therapy has been demonstrated in middle-aged patients with paroxysmal AF, the role the procedure in other patient subgroups-particularly those with long-standing persistent AF-has not been well defined. Furthermore, although AF ablation can be performed with reasonable efficacy and safety by experienced operators, long-term success rates for single procedures are suboptimal. Fortunately, extensive ongoing research will improve our understanding of the mechanisms of AF, and considerable funds are being invested in developing new ablation technologies to improve patient outcomes. These technologies include ablation catheters designed to electrically isolate the pulmonary veins with improved safety, efficacy, and speed, catheters designed to deliver radiofrequency energy with improved precision, robotic systems to address the technological demands of the procedure, improved imaging and electrical mapping systems, and MRI-guided ablation strategies. The tools, technologies, and techniques that will ultimately stand the test of time and become the standard approach to AF ablation in the future remain unclear. However, technological advances are sure to result in the necessary improvements in the safety and efficacy of AF ablation procedures.

  16. Novel robotic catheter manipulation system integrated with remote magnetic navigation for fully remote ablation of atrial tachyarrhythmias: a two-centre evaluation.

    PubMed

    Nölker, Georg; Gutleben, Klaus-Jürgen; Muntean, Bogdan; Vogt, Jürgen; Horstkotte, Dieter; Dabiri Abkenari, Lara; Akca, Ferdi; Szili-Torok, Tamas

    2012-12-01

    Studies have shown that remote magnetic navigation is safe and effective for ablation of atrial arrhythmias, although optimal outcomes often require frequent manual manipulation of a circular mapping catheter. The Vdrive robotic system ('Vdrive') was designed for remote navigation of circular mapping catheters to enable a fully remote procedure. This study details the first human clinical experience with remote circular catheter manipulation in the left atrium. This was a prospective, multi-centre, non-randomized consecutive case series that included patients presenting for catheter ablation of left atrial arrhythmias. Remote systems were used exclusively to manipulate both the circular mapping catheter and the ablation catheter. Patients were followed through hospital discharge. Ninety-four patients were included in the study, including 23 with paroxysmal atrial fibrillation (AF), 48 with persistent AF, and 15 suffering from atrial tachycardias. The population was predominately male (77%) with a mean age of 60.5 ± 11.7 years. The Vdrive was used for remote navigation between veins, creation of chamber maps, and gap identification with segmental isolation. The intended acute clinical endpoints were achieved in 100% of patients. Mean case time was 225.9 ± 70.5 min. Three patients (3.2%) crossed over to manual circular mapping catheter navigation. There were no adverse events related to the use of the remote manipulation system. The results of this study demonstrate that remote manipulation of a circular mapping catheter in the ablation of atrial arrhythmias is feasible and safe. Prospective randomized studies are needed to prove efficiency improvements over manual techniques.

  17. Impact of catheter ablation with remote magnetic navigation on procedural outcomes in patients with persistent and long-standing persistent atrial fibrillation.

    PubMed

    Jin, Qi; Pehrson, Steen; Jacobsen, Peter Karl; Chen, Xu

    2015-11-01

    The objectives of this study were to assess the procedural outcomes of persistent and long-standing persistent atrial fibrillation (PsAF and L-PsAF) ablation guided by remote magnetic navigation (RMN), and to detect factors predicting acute restoration of sinus rhythm (SR) by ablation with RMN. A total of 313 patients (275 male, age 59 ± 9.5 years) with PsAF (187/313) or L-PsAF (126/313) undergoing ablation using RMN were included. Patients' disease history, pulmonary venous anatomy, left atrial (LA) volume, procedure time, mapping plus ablation time, radiofrequency (RF) ablation time, fluoroscopy time, radiation dose, and complications were assessed. Stepwise regression was used to predict which variable could best predict acute restoration from AF to SR by ablation. Compared to PsAF, procedure time and RF ablation time were significantly increased in patients with L-PsAF (P = 0.01 and P < 0.001, respectively). No major complications occurred during the procedures in either PsAF or L-PsAF patients. Fifty five of 313 patients converted directly to SR by ablation. Compared to L-PsAF, the rate of SR restoration was significantly higher in PsAF (21 vs 12%, P = 0.03). Stepwise regression analysis showed LA volume was the primary parameter affecting SR restoration (P = 0.01). The LA volume of patients without direct SR restoration by ablation was 24% greater than that of patients with SR restoration (P < 0.001). Catheter ablation using RMN is a safe and effective method for PsAF and L-PsAF. LA volume could be a predictor of direct restoration of SR from sustaining AF by ablation using RMN.

  18. Common Atrial Fibrillation Risk Alleles at 4q25 Predict Recurrence after Catheter-based Atrial Fibrillation Ablation

    PubMed Central

    Shoemaker, M. Benjamin; Muhammad, Raafia; Parvez, Babar; White, Brenda W.; Streur, Megan; Song, Yanna; Stubblefield, Tanya; Kucera, Gayle; Blair, Marcia; Rytlewski, Jason; Parvathaneni, Sunthosh; Nagarakanti, Rangadham; Saavedra, Pablo; Ellis, Christopher; Whalen, S. Patrick; Roden, Dan M; Darbar, Dawood

    2012-01-01

    Background Common single nucleotide polymorphisms (SNPs) at chromosome 4q25 (rs2200733, rs10033464) are associated with both lone and typical AF. Risk alleles at 4q25 have recently been shown to predict recurrence of AF after ablation in a population of predominately lone AF, but lone AF represents only 5–30% of AF cases. Objective To test the hypothesis that 4q25 AF risk alleles can predict response to AF ablation in the majority of AF cases. Methods Patients enrolled in the Vanderbilt AF Registry underwent 378 catheter-based AF ablations (median age 60 years, 71% male, 89% typical AF) between 2004 and 2011. The primary endpoint was time to recurrence of any non-sinus atrial tachyarrhythmia (atrial tachycardia, atrial flutter, or AF; [AT/AF]). Results Two-hundred AT/AF recurrences (53%) were observed. In multivariable analysis, the rs2200733 risk allele predicted a 24% shorter recurrence-free time (survival time ratio 0.76 95% confidence interval [CI] 0.6–0.95, P=0.016) compared with wild-type. The heterozygous haplotype demonstrated a 21% shorter recurrence-free time (survival time ratio = 0.79, 95% CI 0.62–0.99) and the homozygous risk allele carriers a 39% shorter recurrence-free time (survival time ratio = 0.61, 95% CI 0.37–1.0) (P=0.037). Conclusion Risk alleles at the 4q25 loci predict impaired clinical response to AF ablation in a population of predominately typical AF patients. Our findings suggest the rs2200733 polymorphism may hold promise as an as an objectively measured patient characteristic that can used as a clinical tool for selection of patients for AF ablation. PMID:23178686

  19. [Impact of CHA2DS2 VASc score on substrate for persistent atrial fibrillation and outcome post catheter ablation of atrial fibrillation].

    PubMed

    Ribo, Tang; Jianzeng, Dong; Xiaohui, Liu; Meisheng, Shang; Ronghui, Yu; Deyong, Long; Xin, Du; Junping, Kang; Jiahui, Wu; Man, Ning; Caihua, Sang; Chenxi, Jiang; Rong, Bai; Songnan, Li; Yan, Yao; Songnan, Wen; Changsheng, Ma

    2015-08-01

    To explore if CHA2DS2 VASc score can predict substrate for persistent atrial fibrillation ( AF) and outcome post catheter ablation of AF. From January 2011 to December 2012,116 patients underwent catheter ablation of persistent AF in our department and were enrolled in this study. CHA2DS2VASc score was calculated as follows: two points were assigned for a history of stroke or transient ischemic attack and age ≥ 75 and 1 point each was assigned for age ≥ 65, a history of hypertension, diabetes,recent cardiac failure, vessel disease, female. Left atrial geometry ( LA) was reconstructed with a 3.5 mm tip ablation catheter with fill-in threshold 10 in CARTO system. The mapping catheter was stabled at each endocardial location for at least 3 seconds for recording. The electrogram recordings at each endocardial location were analyzed with a custom software embedded in the CARTO mapping system. Interval confidence level (ICL) was used to characterize complex fractionated atrial electrograms (CFAEs) . As the default setting of the software, ICL more than or equal to 7 was considered sites with a highly repetitive CFAEs complex. CFAEs index was defined as the fraction of area of ICL more than or equal to 7 to the left atrial surface. The CFAEs index and outcome of catheter ablation among different CHA2DS2VASc groups were compared. Of the 116 patients, CHA2DS2VASc was 0 in 33 patients, 1 in 31 patients and ≥ 2 in 52 patients. Left atrial surface ((121.2 ± 18.9) cm2, (133.6 ± 23.8) cm2, (133.9 ± 16.1) cm2, P = 0.008), left atrial volume ((103.6 ± 24.8) ml, (118.3 ± 27.8) ml, (120.9 ± 20.9) ml, P = 0.005) and CFAEs index (44.6% ± 22.4%, 54.2% ± 22.2%, 58.7% ± 23.1%, P = 0.023) increased in proportion with increasing CHA2DS2VASc. ICLmax, ICLmin and CFAEs spatial distribution were similar among the three groups. During the mean follow-up of (13 ± 8) months, the recurrence rate were 36.4%, 35.5%, 55.8% among the three groups (P = 0.025). A high CHA2DS2VASc score

  20. THE MECHANISM OF LESION FORMATION BY FOCUSED ULTRASOUND ABLATION CATHETER FOR TREATMENT OF ATRIAL FIBRILLATION

    PubMed Central

    Sinelnikov, Y.D.; Fjield, T.; Sapozhnikov, O.A.

    2009-01-01

    The application of therapeutic ultrasound for the treatment of atrial fibrillation (AF) is investigated. The results of theoretical and experimental investigation of ultrasound ablation catheter are presented. The major components of the catheter are the high power cylindrical piezoelectric element and parabolic balloon reflector. Thermal elevation in the ostia of pulmonary veins is achieved by focusing the ultrasound beam in shape of a torus that transverses the myocardial tissue. High intensity ultrasound heating in the focal zone results in a lesion surrounding the pulmonary veins that creates an electrical conduction blocks and relief from AF symptoms. The success of the ablation procedure largely depends on the correct choice of reflector geometry and ultrasonic power. We present a theoretical model of the catheter’s acoustic field and bioheat transfer modeling of cardiac lesions. The application of an empirically derived relation between lesion formation and acoustic power is shown to correlate with the experimental data. Developed control methods combine the knowledge of theoretical acoustics and the thermal lesion formation simulations with experiment and thereby establish rigorous dosimetry that contributes to a safe and effective ultrasound ablation procedure. PMID:20161431

  1. Temporal trends in safety and complication rates of catheter ablation for atrial fibrillation.

    PubMed

    Muthalaly, Rahul G; John, Roy M; Schaeffer, Benjamin; Tanigawa, Shinichi; Nakamura, Tomofumi; Kapur, Sunil; Zei, Paul C; Epstein, Laurence M; Tedrow, Usha B; Michaud, Gregory F; Stevenson, William G; Koplan, Bruce A

    2018-06-01

    Atrial fibrillation (AF) ablation is increasingly common, but is associated with potential major complications. Technology, experience, and protocols have evolved significantly in recent times, and may have impacted procedural safety. We sought to compare AF ablation safety profiles, including complication rates and fluoroscopy times in a "modern" versus "historical" cohort. We evaluated consecutive patients undergoing AF ablation from a modern cohort (MC) from 2014 to 2015 and a historic cohort (HC) from 2009 to 2011 for complications. Major complications were categorized according to Heart Rhythm Society guidelines. We included 1,425 patients, 726 in the HC and 699 in the MC. The MC was older, had more OSA and less valvular AF. Fifty-two (3.5%) procedures suffered major complications across the cohorts, with significantly fewer in the MC (5.0% vs. 2.3%, P  =  0.007). The largest reductions were seen in vascular, hemorrhagic, ischemic stroke, and perforation/tamponade related complications. Periprocedural antiplatelets drugs (aHR 2.1 [95 CI 1.1-3.9], P  =  0.02) and force-sensing catheters (aHR 0.4 [95 CI 0.2-0.9], P  =  0.03) were independently related to major complication rates. Direct oral anticoagulants and uninterrupted anticoagulation were not associated with complications. There was a decrease in both fluoroscopy (-17.4 minutes [95 CI 19.2-15.6], P < 0.0001) and radiofrequency ablation times (-561 seconds [95CI -750 to -371], P < 0.0001). The safety profile of AF ablation has improved significantly in less than a decade. © 2018 Wiley Periodicals, Inc.

  2. Emergency catheter ablation in critical patients

    PubMed Central

    Tebbenjohanns, Jürgen; Rühmkorf, Klaus

    2010-01-01

    Emergency catheter ablation is justified in critical patients with drug-refractory life-threatening arrhythmias. The procedure can be used for ablation of an accessory pathway in preexcitation syndrome with high risk of ventricular fibrillation and in patients with shock due to ischemic cardiomyopathy and incessant ventricular tachycardia. Emergency catheter ablation can also be justified in patients with an electrical storm of the implanted cardioverter-defibrillator or in patients with idiopathic ventricular fibrillation. PMID:20606793

  3. Low rate of asymptomatic cerebral embolism and improved procedural efficiency with the novel pulmonary vein ablation catheter GOLD: results of the PRECISION GOLD trial

    PubMed Central

    De Greef, Yves; Dekker, Lukas; Boersma, Lucas; Murray, Stephen; Wieczorek, Marcus; Spitzer, Stefan G.; Davidson, Neil; Furniss, Steve; Hocini, Mélèze; Geller, J. Christoph; Csanádi, Zoltan

    2016-01-01

    Abstract Aims This prospective, multicentre study (PRECISION GOLD) evaluated the incidence of asymptomatic cerebral embolism (ACE) after pulmonary vein isolation (PVI) using a new gold multi-electrode radiofrequency (RF) ablation catheter, pulmonary vein ablation catheter (PVAC) GOLD. Also, procedural efficiency of PVAC GOLD was compared with ERACE. The ERACE study demonstrated that a low incidence of ACE can be achieved with a platinum multi-electrode RF catheter (PVAC) combined with procedural manoeuvres to reduce emboli. Methods and results A total of 51 patients with paroxysmal atrial fibrillation (AF) (age 57 ± 9 years, CHA2DS2-VASc score 1.4 ± 1.4) underwent AF ablation with PVAC GOLD. Continuous oral anticoagulation using vitamin K antagonists, submerged catheter introduction, and heparinization (ACT ≥ 350 s prior to ablation) were applied. Cerebral magnetic resonance imaging (MRI) scans were performed within 48 h before and 16–72 h post-ablation. Cognitive function assessed by the Mini-Mental State Exam at baseline and 30 days post-ablation. New post-procedural ACE occurred in only 1 of 48 patients (2.1%) and was not detectable on MRI after 30 days. The average number of RF applications per patient to achieve PVI was lower in PRECISION GOLD (20.3 ± 10.0) than in ERACE (28.8 ± 16.1; P = 0.001). Further, PVAC GOLD ablations resulted in significantly fewer low-power (<3 W) ablations (15 vs. 23%, 5 vs. 10% and 2 vs. 7% in 4:1, 2:1, and 1:1 bipolar:unipolar energy modes, respectively). Mini-Mental State Exam was unchanged in all patients. Conclusion Atrial fibrillation ablation with PVAC GOLD in combination with established embolic lowering manoeuvres results in a low incidence of ACE. Pulmonary vein ablation catheter GOLD demonstrates improved biophysical efficiency compared with platinum PVAC. Trial registration ClinicalTrials.gov NCT01767558. PMID:26826134

  4. The modified stepwise ablation guided by low-dose ibutilide in chronic atrial fibrillation trial (The MAGIC-AF Study).

    PubMed

    Singh, Sheldon M; d'Avila, Andre; Kim, Young-Hoon; Aryana, Arash; Mangrum, J Michael; Michaud, Gregory F; Dukkipati, Srinivas R; Barrett, Conor D; Heist, E Kevin; Parides, Michael K; Thorpe, Kevin E; Reddy, Vivek Y

    2016-05-21

    Complex fractionated atrial electrograms (CFAE) are targeted during persistent atrial fibrillation (AF) ablation. However, many CFAE sites are non-specific resulting in extensive ablation. Ibutilide has been shown to reduce left atrial surface area exhibiting CFAE. We hypothesized that ibutilide administration prior to CFAE ablation would identify sites critical for persistent AF maintenance allowing for improved procedural efficacy and long-term freedom from atrial arrhythmias. Two hundred patients undergoing a first-ever persistent AF catheter ablation procedure were randomly assigned to receive either 0.25 mg of intravenous ibutilide or saline placebo upon completion of pulmonary vein isolation. Complex fractionated atrial electrogram sites were then targeted with ablation. The primary efficacy endpoint was the 1-year single procedure freedom from atrial arrhythmia off anti-arrhythmic drugs. Similar procedural characteristics (procedure, fluoroscopy, and ablation times) were observed with both strategies despite a greater reduction in left atrial surface area with CFAE sites (8 vs. 1%, P < 0.0001) and AF termination during CFAE ablation with ibutilide compared with placebo (75 vs. 57%, P = 0.007). The primary efficacy endpoint was achieved in 56% of patients receiving ibutilide and 49% receiving placebo (P = 0.35). No significant differences in peri-procedural complications were observed in both groups. Despite a reduction in CFAE area and greater AF termination during CFAE ablation, procedural characteristics and clinical outcomes were unchanged when CFAE ablation was guided by ibutilide administration. ClinicalTrials.gov number: NCT01014741. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2016. For permissions please email: journals.permissions@oup.com.

  5. Long-term outcomes of the current remote magnetic catheter navigation technique for ablation of atrial fibrillation.

    PubMed

    Yuan, Shiwen; Holmqvist, Fredrik; Kongstad, Ole; Jensen, Steen M; Wang, Lingwei; Ljungström, Erik; Hertervig, Eva; Borgquist, Rasmus

    2017-12-01

    Comparisons between remote magnetic (RMN) and manual catheter navigation for atrial fibrillation (AF) ablation have earlier been reported with controversial results. However, these reports were based on earlier generations of the RMN system. To evaluate the outcomes of the most current RMN system for AF ablation in a larger patient population with longer follow-up time, 112 patients with AF (78 paroxysmal, 34 persistent) who underwent AF ablation utilizing RMN (RMN group) were compared to 102 AF ablation patients (72 paroxysmal, 30 persistent) utilizing manual technique (Manual group). The RMN group was associated with significantly shorter fluoroscopy time (10.4 ± 6.4 vs. 16.3 ± 10.9 min, p < .001) but used more RF energy (64.1 ± 19.4KJ vs. 54.3 ± 24.1 KJ, p < .05), while total procedure time showed no significant difference (201 ± 35 vs. 196 ± 44 min, NS). After 39 ± 9/44 ± 10 months of follow-up, AF-free rates at 1year, 2 years and 3.5 years post ablation were 63%, 46% and 42% in the RMN group vs. 60%, 32% and 30% (survival analysis p < .05) in the Manual group, whereas clinically effective rates were 82%, 73% and 70% for the former vs. 70%, 56% and 49% for the latter (survival analysis p < .005). Differing from previous reports, our data from a larger patient population and longer follow-up time demonstrates that compared to manual technique, the most current RMN technique is associated with better procedural and clinical outcomes for AF ablation.

  6. Randomised clinical trial of cryoballoon versus irrigated radio frequency catheter ablation for atrial fibrillation-the effect of double short versus standard exposure cryoablation duration during pulmonary vein isolation (CIRCA-DOSE): methods and rationale.

    PubMed

    Andrade, Jason G; Deyell, Marc W; Badra, Mariano; Champagne, Jean; Dubuc, Marc; Leong-Sit, Peter; Macle, Laurent; Novak, Paul; Roux, Jean-Francois; Sapp, John; Tang, Anthony; Verma, Atul; Wells, George A; Khairy, Paul

    2017-10-05

    Pulmonary vein isolation (PVI) is an effective therapy for paroxysmal atrial fibrillation (AF), but it has limitations. The two most significant recent advances have centred on the integration of real-time quantitative assessment of catheter contact force into focal radio frequency (RF) ablation catheters and the development of dedicated ablation tools capable of achieving PVI with a single ablation lesion (Arctic Front cryoballoon, Medtronic, Minneapolis, MN, USA). Although each of these holds promise for improving the clinical success of catheter ablation of AF, there has not been a rigorous comparison of these advanced ablation technologies. Moreover, the optimal duration of cryoablation (freezing time) has not been determined. Patients undergoing an initial PVI procedure for paroxysmal AF will be recruited. Patients will be randomised 1:1:1 between contact-force irrigated RF ablation, short duration cryoballoon ablation (2 min applications) and standard duration cryoballoon ablation (4 min applications). The primary outcome is time to first documented AF recurrence on implantable loop recorder. With a sample size of 111 per group and a two-sided 0.025 significance level (to account for the two main comparisons), the study will have 80% power (using a log-rank test) to detect a difference of 20% between contact force RF catheter ablation and either of the two cryoballoon ablation groups. Factoring in a 4% loss to follow-up, 116 patients per group should be randomised and followed for a year (total study population of 348). The study was approved by the University of British Columbia Office of Research (Services) Ethics Clinical Research Ethics Board. Results of the study will be submitted for publication in a peer-reviewed journal. NCT01913522; Pre-results. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  7. Pulmonary vein activity does not predict the outcome of catheter ablation for persistent atrial fibrillation: A long-term multicenter prospective study.

    PubMed

    Prabhu, Sandeep; Kalla, Manish; Peck, Kah Y; Voskoboinik, Aleksandr; McLellan, Alex J A; Pathik, Bupesh; Nalliah, Chrishan J; Wong, Geoff R; Sugumar, Hariharan; Azzopardi, Sonia M; Lee, Geoffrey; Ling, Liang-Han; Kalman, Jonathan M; Kistler, Peter M

    2018-03-02

    Pulmonary vein (PV) isolation (PVI) remains the cornerstone of catheter ablation (CA) in persistent atrial fibrillation (AF) (PeAF), although less successful than for paroxysmal AF. Whether rapid or fibrillatory (PV AF) PV firing may identify patients with PeAF more likely to benefit from a PV-based ablation approach is unclear. The purpose of this study was to determine the relationship between the PV cycle length (PVCL) and the PV AF outcome after CA. Before ablation, the multipolar catheter was placed in each PV and the left atrial appendage (LAA) for 100 consecutive cycles. The presence of PV AF, the average PVCL of all 4 veins (PV 4VAverage ), the fastest vein average (PV FVAverage ), the fastest cycle length (PV Fast ) both individually and relative to the average LAA cycle length were calculated. The ablation strategy included PVI and posterior wall isolation with a minimum of 12 months follow-up. A total of 123 patients underwent CA (age 62 ± 9.1 years; CHA 2 DS 2 -VASC score 1.6 ± 1.1; left ventricular ejection fraction 48% ± 13%; left atrial area 31 ± 8.7 cm 2 ; AF duration 16 ± 17 months). PVI was achieved in 100% of patients. Multiprocedure success (MPS; freedom from AF/atrial tachycardia episodes lasting >30 seconds) was achieved in 76% of patients at 24 ± 8.1 months of follow-up after 1.2 ± 0.4 procedures. PV activity was not associated with MPS either absolutely (PV 4VAverage [MPS no vs yes: 178 ± 27 ms vs 177 ± 24 ms; P = .92], PV FVAverage [P = .69], or PV Fast [P = .82]) or as a ratio relative to the LAA cycle length (PV 4VAverage /LAA 1.05 ± 0.11 vs 1.06 ± 0.21; P = .87). The presence of PV AF (31% vs 47%; P = .13) did not predict MPS. The rapidity of PV firing or presence of fibrillation within the PV was not predictive of outcome of CA for PeAF. PV activity does not identify patients most likely to benefit from a PV-based ablation strategy. Copyright © 2018 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  8. Atrial rhythm influences catheter tissue contact during radiofrequency catheter ablation of atrial fibrillation: comparison of contact force between sinus rhythm and atrial fibrillation.

    PubMed

    Matsuda, Hisao; Parwani, Abdul Shokor; Attanasio, Philipp; Huemer, Martin; Wutzler, Alexander; Blaschke, Florian; Haverkamp, Wilhelm; Boldt, Leif-Hendrik

    2016-09-01

    Catheter tissue contact force (CF) is an important factor for durable lesion formation during radiofrequency catheter ablation (RFCA) of atrial fibrillation (AF). Since CF varies in the beating heart, atrial rhythm during RFCA may influence CF. A high-density map and RFCA points were obtained in 25 patients undergoing RFCA of AF using a CF-sensing catheter (Tacticath, St. Jude Medical). The operators were blinded to the CF information. Contact type was classified into three categories: constant, variable, and intermittent contact. Average CF and contact type were analyzed according to atrial rhythm (SR vs. AF) and anatomical location. A total of 1364 points (891 points during SR and 473 points during AF) were analyzed. Average CFs showed no significant difference between SR (17.2 ± 11.3 g) and AF (17.2 ± 13.3 g; p = 0.99). The distribution of points with an average CF of ≥20 and <10 g also showed no significant difference. However, the distribution of excessive CF (CF ≥40 g) was significantly higher during AF (7.4 %) in comparison with SR (4.2 %; p < 0.05). At the anterior area of the right inferior pulmonary vein (RIPV), the average CF during AF was significantly higher than during SR (p < 0.05). Constant contact was significantly higher during AF (32.2 %) when compared to SR (9.9 %; p < 0.01). Although the average CF was not different between atrial rhythms, constant contact was more often achievable during AF than it was during SR. However, excessive CF also seems to occur more frequently during AF especially at the anterior part of RIPV.

  9. Interatrial septum thickness and difficulty with transseptal puncture during redo catheter ablation of atrial fibrillation.

    PubMed

    Tomlinson, David R; Sabharwal, Nikant; Bashir, Yaver; Betts, Timothy R

    2008-12-01

    Patients undergoing catheter ablation for atrial fibrillation (AF) frequently require redo procedures, but there are no data reporting interatrial septum thickness (IAS) and difficulty during repeat transseptal puncture (TSP). Patients undergoing two separate AF ablation procedures had preprocedural fossa ovalis (FO) thickness measured using transesophageal echocardiography (TEE). "Difficult" TSP was defined by two observers as requiring excessive force, or conversion to TEE guidance. The study comprised 42 patients (37 male) with mean+/-SD age 55+/-9 years. Mean FO thickness was significantly greater at the time of redo TSP (2.2+/-1.6 mm vs 2.6+/-1.5 mm at redo, P=0.03); however, this finding was limited to those who underwent initial dual transseptal sheath procedures, FO thickness 2.0+/-1.5 mm and 2.5+/-1.4 mm for TEE 1 and 2, respectively (P=0.048). There was a trend for more frequent difficult redo TSP procedures, 7/42 (17%; 95% confidence interval [CI] 8-31) redo, versus 4/42 (10%; 95% CI 3-23) first TSP. On univariate analysis, FO thickness was not predictive of TSP difficulty; the only predictor of difficult redo TSP was diabetes. IAS thickness at the FO increased following catheter ablation of AF, yet on subgroup analysis this was limited to initial procedures utilizing dual transseptal sheaths. There was a trend toward more frequent difficulty during redo TSP, yet this was not associated with FO thickening. Diabetes may predispose to difficulty during redo TSP; this finding requires confirmation in a larger study population.

  10. Temporal trends of in-hospital complications associated with catheter ablation of atrial fibrillation in the United States: An update from Nationwide Inpatient Sample database (2011-2014).

    PubMed

    Tripathi, Byomesh; Arora, Shilpkumar; Kumar, Varun; Abdelrahman, Mohamed; Lahewala, Sopan; Dave, Mihir; Shah, Mahek; Tan, Bryan; Savani, Sejal; Badheka, Apurva; Gopalan, Radha; Shantha, Ghanshyam Palamaner Subash; Viles-Gonzalez, Juan; Deshmukh, Abhishek

    2018-05-01

    Catheter ablation is widely accepted intervention for atrial fibrillation (AF) refractory to antiarrhythmic drugs, but limited data are available regarding contemporary trends in major complications and in-hospital mortality due to the procedure. This study was aimed at exploring the temporal trends of in-hospital mortality, major complications, and impact of hospital volume on frequency of AF ablation-related outcomes. The Nationwide Inpatient Sample database was utilized to identify the AF patients treated with catheter ablation. In-hospital death and common complications including vascular access complications, cardiac perforation and/or tamponade, pneumothorax, stroke, and transient ischemic attack, were identified using International Classification of Disease (ICD-9-CM) codes. In-hospital mortality rate of 0.15% and overall complication rate of 5.46% were noted among AF ablation recipients (n = 50,969). Significant increase in complications during study period (relative increase 56.37%, P-trend < 0.001) was observed. Cardiac (2.65%), vascular (1.33%), and neurological (1.05%) complications were most common. On multivariate analysis (odds ratio [OR]; 95% confidence interval [95% CI]; P value), significant predictors of complications were female sex (OR = 1.40; CI = 1.17-1.68; P value < 0.001), high burden of comorbidity as indicated by Charlson Comorbidity Index ≥2 (OR = 2.84; CI = 2.29-3.52; P value < 0.001), and low hospital volume (< 50 procedures). Our study noted a decline in AF ablation-related hospitalizations and complications associated with the procedure. These findings largely reflect shifting trends of outpatient performance of the procedure and increasing safety profile due to improved institutional expertise and catheter techniques. © 2018 Wiley Periodicals, Inc.

  11. Low rate of asymptomatic cerebral embolism and improved procedural efficiency with the novel pulmonary vein ablation catheter GOLD: results of the PRECISION GOLD trial.

    PubMed

    De Greef, Yves; Dekker, Lukas; Boersma, Lucas; Murray, Stephen; Wieczorek, Marcus; Spitzer, Stefan G; Davidson, Neil; Furniss, Steve; Hocini, Mélèze; Geller, J Christoph; Csanádi, Zoltan

    2016-05-01

    This prospective, multicentre study (PRECISION GOLD) evaluated the incidence of asymptomatic cerebral embolism (ACE) after pulmonary vein isolation (PVI) using a new gold multi-electrode radiofrequency (RF) ablation catheter, pulmonary vein ablation catheter (PVAC) GOLD. Also, procedural efficiency of PVAC GOLD was compared with ERACE. The ERACE study demonstrated that a low incidence of ACE can be achieved with a platinum multi-electrode RF catheter (PVAC) combined with procedural manoeuvres to reduce emboli. A total of 51 patients with paroxysmal atrial fibrillation (AF) (age 57 ± 9 years, CHA2DS2-VASc score 1.4 ± 1.4) underwent AF ablation with PVAC GOLD. Continuous oral anticoagulation using vitamin K antagonists, submerged catheter introduction, and heparinization (ACT ≥ 350 s prior to ablation) were applied. Cerebral magnetic resonance imaging (MRI) scans were performed within 48 h before and 16-72 h post-ablation. Cognitive function assessed by the Mini-Mental State Exam at baseline and 30 days post-ablation. New post-procedural ACE occurred in only 1 of 48 patients (2.1%) and was not detectable on MRI after 30 days. The average number of RF applications per patient to achieve PVI was lower in PRECISION GOLD (20.3 ± 10.0) than in ERACE (28.8 ± 16.1; P = 0.001). Further, PVAC GOLD ablations resulted in significantly fewer low-power (<3 W) ablations (15 vs. 23%, 5 vs. 10% and 2 vs. 7% in 4:1, 2:1, and 1:1 bipolar:unipolar energy modes, respectively). Mini-Mental State Exam was unchanged in all patients. Atrial fibrillation ablation with PVAC GOLD in combination with established embolic lowering manoeuvres results in a low incidence of ACE. Pulmonary vein ablation catheter GOLD demonstrates improved biophysical efficiency compared with platinum PVAC. ClinicalTrials.gov NCT01767558. © The Author 2016. Published by Oxford University Press on behalf of the European Society of Cardiology.

  12. Cost-Effectiveness of Radiofrequency Catheter Ablation Compared with Antiarrhythmic Drug Therapy for Paroxysmal Atrial Fibrillation

    PubMed Central

    Reynolds, Matthew R.; Zimetbaum, Peter; Josephson, Mark E.; Ellis, Ethan; Danilov, Tatyana; Cohen, David J.

    2009-01-01

    Background Radiofrequency catheter ablation (RFA) has emerged as an important treatment strategy for AF. The potential cost-effectiveness of RFA for AF, relative to antiarrhythmic drug (AAD) therapy, has not been fully explored from a U.S. perspective. Methods and Results We constructed a Markov disease simulation model for a hypothetical cohort of drug- refractory paroxysmal AF patients managed either with RFA ± AAD or AAD alone. Costs and quality-adjusted life years (QALYs) were projected over 5 years. Model inputs were drawn from published clinical trial and registry data, from new registry and trial data analysis, and from data prospectively collected from AF patients managed with RFA at our institution. We assumed no benefit form ablation on stroke, heart failure or death, but did estimate changes in quality-adjusted life expectancy using data from several AF cohorts. In the base case scenario, cumulative costs with the RFA and AAD strategies were $26,584 and $19,898, respectively. Over 5 years, quality adjusted life expectancy was 3.51 QALYs with RFA, versus 3.38 for the AAD group. The incremental cost-effectiveness ratio for RFA vs. AAD was thus $51,431/QALY. Model results were most sensitive to time horizon, the relative utility weights of successful ablation vs. unsuccessful drug therapy, and to the cost of an ablation procedure. Conclusions RFA ± AAD for symptomatic, drug-refractory paroxysmal AF appears to be reasonably cost-effective compared with AAD therapy alone from the perspective of the US health care system, based on improved quality of life and avoidance of future health care costs. PMID:19808491

  13. Association of Left Atrial Function Index With Late Atrial Fibrillation Recurrence after Catheter Ablation.

    PubMed

    Sardana, Mayank; Ogunsua, Adedotun A; Spring, Matthew; Shaikh, Amir; Asamoah, Owusu; Stokken, Glenn; Browning, Clifford; Ennis, Cynthia; Donahue, J Kevin; Rosenthal, Lawrence S; Floyd, Kevin C; Aurigemma, Gerard P; Parikh, Nisha I; McManus, David D

    2016-12-01

    Although catheter ablation (CA) for atrial fibrillation (AF) is commonly used to improve symptoms, AF recurrence is common and new tools are needed to better inform patient selection for CA. Left atrial function index (LAFI), an echocardiographic measure of atrial mechanical function, has shown promise as a noninvasive predictor of AF. We hypothesized that LAFI would relate to AF recurrence after CA. All AF patients undergoing index CA were enrolled in a prospective institutional AF Treatment Registry between 2011 and 2014. LAFI was measured post hoc from pre-ablation clinical echocardiographic images in 168 participants. Participants were mostly male (33% female), middle-aged (60 ± 10 years), obese and had paroxysmal AF (64%). Mean LAFI was 25.9 ± 17.6. Over 12 months of follow-up, 78 participants (46%) experienced a late AF recurrence. In logistic regression analyses adjusting for factors known to be associated with AF, lower LAFI remained associated with AF recurrence after CA [OR 0.04 (0.01-0.67), P = 0.02]. LAFI discriminated AF recurrence after CA slightly better than CHADS2 (C-statistic 0.60 LAFI, 0.57 CHADS2). For participants with persistent AF, LAFI performed significantly better than CHADS2 score (C statistic = 0.79 LAFI, 0.56 CHADS2, P = 0.02). LAFI, an echocardiographic measure of atrial function, is associated with AF recurrence after CA and has improved ability to discriminate AF recurrence as compared to the CHADS-2 score, especially among persistent AF patients. Since LAFI can be calculated using standard 2D echocardiographic images, it may be a helpful tool for predicting AF recurrence. © 2016 Wiley Periodicals, Inc.

  14. Comparison of treatment outcomes between convergent procedure and catheter ablation for paroxysmal atrial fibrillation evaluated with implantable loop recorder monitoring.

    PubMed

    Jan, Matevž; Žižek, David; Geršak, Živa Miriam; Geršak, Borut

    2018-05-03

    While catheter ablation (CA) is an established treatment for symptomatic paroxysmal atrial fibrillation (AF), convergent epicardial and endocardial ablation procedure (CVP) has been primarily used to treat persistent AF. The aim of this single-center, prospective, randomized study was to compare treatment efficacy of CA and CVP in paroxysmal AF patients by monitoring AF, atrial tachycardia (AT), and atrial flutter (AFL) recurrence with Implantable Loop Recorder (ILR). Fifty patients (74% male) with history of paroxysmal AF were randomized between CA and CVP. Outcomes were determined by ILRs; every episode of AF/AT/AFL lasting 6 minutes or more was defined as a recurrence. AF burden (AFB) and required AF reinterventions (cardioversions and repeat ablations) were quantified after a 3-month blanking period. Total procedural (266 ± 44 vs. 242 ± 39 minutes) and ablation duration (52 ± 10 vs. 48 ± 12 minutes) was similar in both groups. Recurrence of AF/AT/AFL was more likely in the CA group compared to the CVP group (OR 3.78 (95% CI (1.17, 12.19), P  =  0.048)). During the follow-up period (mean 30.5 ± 6.9 months), higher AF burden and more reinterventions for recurrent AF were recorded in the CA group. There were more periprocedural complications in the CVP group (12.5%) compared to the CA group (0%). Treatment of paroxysmal AF with CVP showed less arrhythmia recurrence compared to CA. In addition, patients after CVP had fewer reinterventions and lower AF burden, but more periprocedural complications. © 2018 Wiley Periodicals, Inc.

  15. Percutaneous intrapericardial echocardiography during catheter ablation: a feasibility study.

    PubMed

    Horowitz, Barbara Natterson; Vaseghi, Marmar; Mahajan, Aman; Cesario, David A; Buch, Eric; Valderrábano, Miguel; Boyle, Noel G; Ellenbogen, Kenneth A; Shivkumar, Kalyanam

    2006-11-01

    Percutaneous pericardial access, epicardial mapping, and ablation have been used successfully for catheter ablation procedures. The purpose of this study was to evaluate the safety and feasibility of closed-chest direct epicardial ultrasound imaging for aiding cardiac catheter ablation procedures. An intracardiac ultrasound catheter was used for closed-chest epicardial imaging of the heart in 10 patients undergoing percutaneous epicardial access for catheter ablation. All patients underwent concomitant intracardiac echocardiography and preprocedural transesophageal echocardiography. Using a double-wire technique, two sheaths were placed in the pericardium, and a phased-array ultrasound catheter was manipulated within the pericardial sinuses for imaging. Multiple images from varying angles were obtained for catheter navigation. Notably, image stability was excellent, and structures such as the left atrial appendage were seen in great detail. No complications resulting from use of the ultrasound catheter in the pericardium occurred, and no restriction of movement due to the presence of the additional catheter in the pericardial space was observed. Wall motion was correlated to voltage maps in five patients and showed that areas of scars correlated with wall-motion abnormalities. Normal wall-motion score correlated to sensed signals of 4.2 +/- 0.3 mV (normal myocardium >1.5 mV), and scores >1 correlated to areas with signals <0.5 mV in that territory). Intrapericardial imaging using an ultrasound catheter is feasible and safe and has the potential to provide additional valuable information for complex ablation procedures.

  16. Biophysics and clinical utility of irrigated-tip radiofrequency catheter ablation.

    PubMed

    Houmsse, Mahmoud; Daoud, Emile G

    2012-01-01

    Catheter ablation by radiofrequency (RF) energy has successfully eliminated cardiac tachyarrhythmias. RF ablation lesions are created by thermal energy. Electrode catheters with 4-mm-tips have been adequate to ablate arrhythmias located near the endocardium; however, the 4-mm-tip electrode does not readily ablate deeper tachyarrhythmia substrate. With 8- and 10-mm-tip RF electrodes, ablation lesions were larger; yet, these catheters are associated with increased risk for coagulum, char and thrombus formation, as well as myocardial steam rupture. Cooled-tip catheter technology was designed to cool the electrode tip, prevent excessive temperatures at the electrode tip-tissue interface, and thus allow continued delivery of RF current into the surrounding tissue. This ablation system creates larger and deeper ablation lesions and minimizes steam pops and thrombus formation. The purpose of this article is to review cooled-tip RF ablation biophysics and outcomes of clinical studies as well as to discuss future technological improvements.

  17. Catheter ablation for atrial fibrillation on uninterrupted direct oral anticoagulants: A safe approach.

    PubMed

    Sawhney, V; Shaukat, M; Volkova, E; Jones, N; Providencia, R; Honarbakhsh, S; Dhillon, G; Chow, A; Lowe, M; Lambiase, P; Dhinoja, M; Sporton, S; Earley, M J; Schilling, R J; Hunter, R J

    2018-05-16

    Current consensus guidelines suggest DOACs are interrupted peri-procedurally for catheter ablation (CA) of AF. However, this may predispose patients to thromboembolic complications. This study investigates the safety of CA for AF on uninterrupted DOACs compared to uninterrupted warfarin. Single centre, retrospective study of consecutive patients undergoing CA for AF. All patients were heparinised prior to trans-septal puncture with a target activated clotting time (ACT) of 300-350 seconds. Patients who had procedures performed on continuous DOAC were compared to those on continuous warfarin. Clinical, procedural data and complications occurring up to 3 months were analysed from a prospective registry with additional review of electronic health records. 1884 procedures were performed over 28 months: 761(609 patients) on uninterrupted warfarin and 1123(900 patients) on uninterrupted DOAC (rivaroxaban 64%, apixaban 32% and dabigatran 4%). There was no difference in the composite end point of death, thromboembolism or major bleeding complication(2.2% vs 1.4%, p = 0.20). There was no difference in the complications comprising this including tamponade, haematoma, pseudoaneurysm, transfusion(p-values 0.28, 0.13, 0.45 and 0.36). There were no strokes, TIAs or other thromboembolic complications. There was no difference between groups in the proportion of tamponades requiring reversal of oral anticoagulation, the volume of blood lost, the proportion transfused, or the proportion drained percutaneously(p-values 0.50, 0.51, 0.36, 0.38). Catheter ablation for AF can be performed safely and effectively in patients anticoagulated with DOACs and heparinised with a therapeutic ACT. There is no increased risk of peri-procedural bleeding when compared to uninterrupted warfarin. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  18. Apixaban for periprocedural anticoagulation during catheter ablation of atrial fibrillation: a systematic review and meta-analysis of 1691 patients.

    PubMed

    Blandino, Alessandro; Bianchi, Francesca; Biondi-Zoccai, Giuseppe; Grossi, Stefano; Conte, Maria Rosa; Rametta, Francesco; Gaita, Fiorenzo

    2016-09-01

    Apixaban, a direct factor Xa inhibitor recently approved for thromboembolic prophylaxis in patients with nonvalvular atrial fibrillation (AF), is increasingly used in patients undergoing catheter ablation of AF. However, large randomized studies supporting its use in the ablation context are still lacking. We undertook the present meta-analysis to assess the impact of apixaban in terms of thromboembolic and bleeding events in patients undergoing AF ablation as compared to warfarin. MEDLINE/PubMed, Cochrane Library, and references reporting AF ablation and apixaban were screened and studies included if matching inclusion and exclusion criteria. One randomized and five nonrandomized studies were included in the analysis. Patients enrolled were 1691 patients (668 on apixaban and 1023 on warfarin). There was no heterogeneity in all the outcome comparisons. No deaths were reported. We did not observe any difference between apixaban and warfarin with respect to thromboembolic events (OR = 1.10, 95 % CI 0.24-5.16), major bleedings (OR = 1.56, 95 % CI 0.59-4.13), cardiac tamponade (OR 1.69, 95 % CI 0.52-5.54), minor bleedings (OR 0.96, 95 % CI 0.58-1.59), and the composite endpoint of death, thromboembolic events, and bleedings (OR 1.03, 95 % CI 0.65-1.64). The rates of death, thromboembolic events, major bleedings including cardiac tamponade, and minor bleedings in patients on apixaban undergoing AF ablation are very low and similar to that seen in patients treated with uninterrupted warfarin. Although primary driven by nonrandomized studies, these results support apixaban as periprocedural anticoagulation during AF ablation procedures.

  19. The effect of elastic modulus on ablation catheter contact area.

    PubMed

    Camp, Jon J; Linte, Cristian A; Rettmann, Maryam E; Sun, Deyu; Packer, Douglas L; Robb, Richard A; Holmes, David R

    2015-02-21

    Cardiac ablation consists of navigating a catheter into the heart and delivering RF energy to electrically isolate tissue regions that generate or propagate arrhythmia. Besides the challenges of accurate and precise targeting of the arrhythmic sites within the beating heart, limited information is currently available to the cardiologist regarding intricate electrode-tissue contact, which directly impacts the quality of produced lesions. Recent advances in ablation catheter design provide intra-procedural estimates of tissue-catheter contact force, but the most direct indicator of lesion quality for any particular energy level and duration is the tissue-catheter contact area, and that is a function of not only force, but catheter pose and material elasticity as well. In this experiment, we have employed real-time ultrasound (US) imaging to determine the complete interaction between the ablation electrode and tissue to accurately estimate contact, which will help to better understand the effect of catheter pose and position relative to the tissue. By simultaneously recording tracked position, force reading and US image of the ablation catheter, the differing material properties of polyvinyl alcohol cryogel [1] phantoms are shown to produce varying amounts of tissue depression and contact area (implying varying lesion quality) for equivalent force readings. We have shown that the elastic modulus significantly affects the surface-contact area between the catheter and tissue at any level of contact force. Thus we provide evidence that a prescribed level of catheter force may not always provide sufficient contact area to produce an effective ablation lesion in the prescribed ablation time.

  20. Remote magnetic versus manual catheter navigation for circumferential pulmonary vein ablation in patients with atrial fibrillation.

    PubMed

    Lüthje, Lars; Vollmann, Dirk; Seegers, Joachim; Dorenkamp, Marc; Sohns, Christian; Hasenfuss, Gerd; Zabel, Markus

    2011-11-01

    Only limited data exist on the clinical utility of remote magnetic navigation (RMN) for pulmonary vein (PV) ablation. Aim of this prospective study was to evaluate the safety and efficacy of RMN for PV isolation as compared to the manual (CON) approach. A total of 161 consecutive patients undergoing circumferential PV isolation were included. Open-irrigated 3.5 mm ablation catheters under the guidance of a mapping system were used. The catheter was navigated with the Stereotaxis Niobe II system in the RMN group (n = 107) and guided manually in the CON group (n = 54). Electrical isolation of all PVs was achieved in 90% of the patients in the RMN group and in 87% in the CON group (p = 0.6). All subjects were followed every 3 months by 7d Holter-ECG. At 12 months of follow-up, 53.5% (RMN) and 55.5% (CON) of the patients were free of any left atrial tachycardia/atrial fibrillation (AF) episode (p = 0.57). Free of symptomatic AF recurrence were 66.3% (RMN) and 62.1% (CON) of the subjects (p = 0.80). Use of RMN was associated with longer procedure duration (p < 0.0001), ablation times (p < 0.0001), and RF current application duration (p < 0.05). In contrast, fluoroscopy time was lower in the RMN group (p < 0.0001). Major complications occurred in 6 of 161 procedures (3.7%), with no significant difference between groups (p = 0.75). RMN-guided PV ablation provides comparable acute and long-term success rates as compared to manual navigation. Procedural complication rates are similar. The use of RMN is associated with markedly reduced fluoroscopy time, but prolonged ablation and procedure duration.

  1. Strict sequential catheter ablation strategy targeting the pulmonary veins and superior vena cava for persistent atrial fibrillation.

    PubMed

    Yoshiga, Yasuhiro; Shimizu, Akihiko; Ueyama, Takeshi; Ono, Makoto; Fukuda, Masakazu; Fumimoto, Tomoko; Ishiguchi, Hironori; Omuro, Takuya; Kobayashi, Shigeki; Yano, Masafumi

    2018-08-01

    An effective catheter ablation strategy, beyond pulmonary vein isolation (PVI), for persistent atrial fibrillation (AF) is necessary. Pulmonary vein (PV)-reconduction also causes recurrent atrial tachyarrhythmias. The effect of the PVI and additional effect of a superior vena cava (SVC) isolation (SVCI) was strictly evaluated. Seventy consecutive patients with persistent AF who underwent a strict sequential ablation strategy targeting the PVs and SVC were included in this study. The initial ablation strategy was a circumferential PVI. A segmental SVCI was only applied as a repeat procedure when patients demonstrated no PV-reconduction. After the initial procedure, persistent AF was suppressed in 39 of 70 (55.7%) patients during a median follow-up of 32 months. After multiple procedures, persistent AF was suppressed in 46 (65.7%) and 52 (74.3%) patients after receiving the PVI alone and PVI plus SVCI strategies, respectively. In 6 of 15 (40.0%) patients with persistent AF resistant to PVI, persistent AF was suppressed. The persistent AF duration independently predicted persistent AF recurrences after multiple PVI alone procedures [HR: 1.012 (95% confidence interval: 1.006-1.018); p<0.001] and PVI plus SVCI strategies [HR: 1.018 (95% confidence interval: 1.011-1.025); p<0.001]. A receiver-operating-characteristic analysis for recurrent persistent AF indicated an optimal cut-off value of 20 and 32 months for the persistent AF duration using the PVI alone and PVI plus SVCI strategies, respectively. The outcomes of the PVI plus SVCI strategy were favorable for patients with shorter persistent AF durations. The initial SVCI had the additional effect of maintaining sinus rhythm in some patients with persistent AF resistant to PVI. Copyright © 2018 Japanese College of Cardiology. Published by Elsevier Ltd. All rights reserved.

  2. Post-procedural evaluation of catheter contact force characteristics

    NASA Astrophysics Data System (ADS)

    Koch, Martin; Brost, Alexander; Kiraly, Atilla; Strobel, Norbert; Hornegger, Joachim

    2012-03-01

    Minimally invasive catheter ablation of electric foci, performed in electrophysiology labs, is an attractive treatment option for atrial fibrillation (AF) - in particular if drug therapy is no longer effective or tolerated. There are different strategies to eliminate the electric foci inducing the arrhythmia. Independent of the particular strategy, it is essential to place transmural lesions. The impact of catheter contact force on the generated lesion quality has been investigated recently, and first results are promising. There are different approaches to measure catheter-tissue contact. Besides traditional haptic feedback, there are new technologies either relying on catheter tip-to-tissue contact force or on local impedance measurements at the tip of the catheter. In this paper, we present a novel tool for post-procedural ablation point evaluation and visualization of contact force characteristics. Our method is based on localizing ablation points set during AF ablation procedures. The 3-D point positions are stored together with lesion specific catheter contact force (CF) values recorded during the ablation. The force records are mapped to the spatial 3-D positions, where the energy has been applied. The tracked positions of the ablation points can be further used to generate a 3-D mesh model of the left atrium (LA). Since our approach facilitates visualization of different force characteristics for post-procedural evaluation and verification, it has the potential to improve outcome by highlighting areas where lesion quality may be less than desired.

  3. Left atrial pressure pattern without a-wave in sinus rhythm after cardioversion affects the outcomes after catheter ablation for atrial fibrillation.

    PubMed

    Kishima, Hideyuki; Mine, Takanao; Takahashi, Satoshi; Ashida, Kenki; Ishihara, Masaharu; Masuyama, Tohru

    2018-04-24

    The a-wave in left atrial pressure (LAP) is often not observed after cardioversion (CV). We hypothesized that repeated atrial fibrillation (AF) occurs in patients who do not show a-wave pattern after CV. We investigated the impact of "LAP pattern without a-wave" on the outcome after catheter ablation (CA) for AF. We studied 100 patients (64 males, age 66 ± 8 years, 42 with non-paroxysmal AF) who underwent CA for AF. Sustained- or induced-AF were terminated with internal CV, and LAP was measured during sinus rhythm (SR) after CV. LAP pattern without a-wave was defined as absence of a-wave (the "a-wave" was defined as a protruding part by 0.2 mmHg or more from the baseline) in LAP wave form. AF was terminated with CV in all patients. Recurrent AF was detected in 35/100 (35%) during the follow-up period (13.1 ± 7.8 month). Univariate analysis revealed higher prevalence of LAP pattern without a-wave (71 vs. 17%, P < 0.0001), larger left atrial volume, elevated E wave, and decreased deceleration time as significant variables. On multivariate analysis, LAP pattern without a-wave was only independently associated with recurrent AF (P = 0.0014, OR 9.865, 95% CI 2.327-54.861). Moreover, patients with LAP pattern without a-wave had a higher risk of recurrent AF than patients with a-wave (25/36 patients, 69 vs. 10/64 patients, 16%, log-rank P < 0.0001). Left atrial pressure pattern without a-wave in sinus rhythm after cardioversion could predict recurrence after catheter ablation for AF.

  4. Accuracy of Voltage Signal Measurement During Radiofrequency Delivery Through the SMARTTOUCH Catheter.

    PubMed

    Safavi-Naeini, Payam; Zafar-Awan, Dreema; Zhu, Hongjian; Zablah, Gerardo; Ganapathy, Anand V; Rasekh, Abdi; Saeed, Mohammad; Razavi, Joanna Esther Molina; Razavi, Mehdi

    2017-01-01

    Current methods for measuring voltage during radiofrequency (RF) ablation (RFA) necessitate turning off the ablation catheter. If voltage could be accurately read without signal attenuation during RFA, turning off the catheter would be unnecessary, allowing continuous ablation. We evaluated the accuracy of the Thermocool SMARTTOUCH catheter for measuring voltage while RF traverses the catheter. We studied 26 patients undergoing RFA for arrhythmias. A 7.5F SMARTTOUCH catheter was used for sensing voltage and performing RFA. Data were collected from the Carto-3 3-dimensional mapping system. Voltages were measured during ablation (RF-ON) and immediately before or after ablation (RF-OFF). In evaluating the accuracy of RF-ON measurements, we utilized the RF-OFF measure as the gold standard. We measured 465 voltage signals. The median values were 0.2900 and 0.3100 for RF-ON and RF-OFF, respectively. Wilcoxon signed rank testing showed no significant difference in these values (P = 0.608). The intraclass correlation coefficient (ICC) was 0.96, indicating that voltage measurements were similarly accurate during RF-OFF versus RF-ON. Five patients had baseline atrial fibrillation (AF), for whom 82 ablation points were measured; 383 additional ablation points were measured for the remaining patients. The voltages measured during RF-ON versus RF-OFF were similar in the presence of AF (P = 0.800) versus non-AF rhythm (P = 0.456) (ICC, 0.96 for both). Voltage signal measurement was similarly accurate during RF-ON versus RF-OFF independent of baseline rhythm. Physicians should consider not turning off the SMARTTOUCH ablation catheter when measuring voltage during RFA. © 2016 Wiley Periodicals, Inc.

  5. Safety and Efficacy of Uninterrupted Apixaban Therapy Versus Warfarin During Atrial Fibrillation Ablation.

    PubMed

    Shah, Ruchit R; Pillai, Ajay; Schafer, Pascha; Meggo, David; McElderry, Tom; Plumb, Vance; Yamada, Takumi; Kumar, Vineet; Doppalapudi, Harish; Gunter, Alicia; Pentecost, Emily; Maddox, William R

    2017-08-01

    Thromboembolic cerebrovascular accident remains a rare but potentially devastating complication of catheter-based atrial fibrillation (AF) ablation. Uninterrupted oral anticoagulant therapy with warfarin has become the standard of care when performing catheter-based AF ablation. Compared with warfarin, apixaban, a factor Xa inhibitor, has been shown to reduce the risk of stroke and major bleeding in nonvalvular AF. With an increase in apixaban use for stroke prophylaxis in patients with AF, there is an increased interest in the safety and efficacy of uninterrupted apixaban therapy during AF ablation. We compared the safety and efficacy of uninterrupted OA therapy with either warfarin or apixaban in all patients who underwent catheter-based AF ablation at the University of Alabama at Birmingham and at Augusta University Medical Center from January 7, 2013, to February 25, 2016. All patients underwent a transesophageal echocardiogram on the day of their ablation to assess for the presence of intracardiac thrombi. All complications were identified and classified as bleeding, thromboembolic events, or other. A total of 627 patients were analyzed as described earlier. There were 310 patients in the warfarin group and 317 patients in the apixaban group. There were 8 complications in the warfarin group and 5 complications in the apixaban group (p = 0.38). There were no thromboembolic complications in either group. In conclusion, the use of apixaban is as safe and effective as warfarin for uninterrupted OA therapy during catheter-based ablation of AF. Copyright © 2017 Elsevier Inc. All rights reserved.

  6. An approach to ablate and pace:AV junction ablation and pacemaker implantation performed concurrently from the same venous access site.

    PubMed

    Issa, Ziad F

    2007-09-01

    Atrioventricular junction (AVJ) ablation combined with permanent pacemaker implantation (the "ablate and pace" approach) remains an acceptable alternative treatment strategy for symptomatic, drug-refractory atrial fibrillation (AF) with rapid ventricular response. This case series describes the feasibility and safety of catheter ablation of the AVJ via a superior vena caval approach performed during concurrent dual-chamber pacemaker implantation. A total of 17 consecutive patients with symptomatic, drug-refractory, paroxysmal AF underwent combined AVJ ablation and dual-chamber pacemaker implantation procedure using a left axillary venous approach. Two separate introducer sheaths were placed into the axillary vein. The first sheath was used for implantation of the pacemaker ventricular lead, which was then connected to the pulse generator. Subsequently, a standard ablation catheter was introduced through the second axillary venous sheath and used for radiofrequency (RF) ablation of the AVJ. After successful ablation, the catheter was withdrawn and the pacemaker atrial lead was advanced through that same sheath and implanted in the right atrium. Catheter ablation of the AVJ was successfully achieved in all patients. The median number of RF applications required to achieve complete AV block was three (range 1-10). In one patient, AV conduction recovered within the first hour after completion of the procedure, and AVJ ablation was then performed using the conventional femoral venous approach. There were no procedural complications. Catheter ablation of the AVJ can be performed successfully and safely via a superior vena caval approach in patients undergoing concurrent dual-chamber pacemaker implantation.

  7. Use of asymmetric bidirectional catheters with different curvature radius for catheter ablation of cardiac arrhythmias.

    PubMed

    Mantziari, Lilian; Suman-Horduna, Irina; Gujic, Marko; Jones, David G; Wong, Tom; Markides, Vias; Foran, John P; Ernst, Sabine

    2013-06-01

    The impact of recently introduced asymmetric bidirectional ablation catheters on procedural parameters and acute success rates of ablation procedures is unknown. We retrospectively analyzed data regarding ablations using a novel bidirectional catheter in a tertiary cardiac center and compared these in 1:5 ratio with a control group of procedures matched for age, gender, operator, and ablation type. A total of 50 cases and 250 controls of median age 60 (50-68) years were studied. Structural heart disease was equally prevalent in both groups (39%) while history of previous ablations was more common in the study arm (54% vs 30%, P = 0.001). Most of the ablation cases were for atrial fibrillation (46%), followed by atrial tachycardia (28%), supraventricular tachycardia (12%), and ventricular tachycardia (14%). Median procedure duration was 128 (52-147) minutes with the bidirectional, versus 143 (105-200) minutes with the conventional catheter (P = 0.232), and median fluoroscopy time was 17 (10-34) minutes versus 23 (12-39) minutes, respectively (P = 0.988). There was a trend toward a lower procedure duration for the atrial tachycardia ablations, 89 (52-147) minutes versus 130 (100-210) minutes, P = 0.064. The procedure was successfully completed in 96% of the bidirectional versus 84% of the control cases (P = 0.151). A negative correlation was observed between the relative fluoroscopy duration and the case number (r = -0.312, P = 0.028), reflecting the learning curve for the bidirectional catheter. The introduction of the bidirectional catheter resulted in no prolongation of procedure parameters and similar success rates, while there was a trend toward a lower procedure duration for atrial tachycardia ablations. ©2013, The Authors. Journal compilation ©2013 Wiley Periodicals, Inc.

  8. Simplified method for esophagus protection during radiofrequency catheter ablation of atrial fibrillation - prospective study of 704 cases

    PubMed Central

    Mateos, José Carlos Pachón; Mateos, Enrique I Pachón; Peña, Tomas G Santillana; Lobo, Tasso Julio; Mateos, Juán Carlos Pachón; Vargas, Remy Nelson A; Pachón, Carlos Thiene C; Acosta, Juán Carlos Zerpa

    2015-01-01

    Introduction Although rare, the atrioesophageal fistula is one of the most feared complications in radiofrequency catheter ablation of atrial fibrillation due to the high risk of mortality. Objective This is a prospective controlled study, performed during regular radiofrequency catheter ablation of atrial fibrillation, to test whether esophageal displacement by handling the transesophageal echocardiography transducer could be used for esophageal protection. Methods Seven hundred and four patients (158 F/546M [22.4%/77.6%]; 52.8±14 [17-84] years old), with mean EF of 0.66±0.8 and drug-refractory atrial fibrillation were submitted to hybrid radiofrequency catheter ablation (conventional pulmonary vein isolation plus AF-Nests and background tachycardia ablation) with displacement of the esophagus as far as possible from the radiofrequency target by transesophageal echocardiography transducer handling. The esophageal luminal temperature was monitored without and with displacement in 25 patients. Results The mean esophageal displacement was 4 to 9.1cm (5.9±0.8 cm). In 680 of the 704 patients (96.6%), it was enough to allow complete and safe radiofrequency delivery (30W/40ºC/irrigated catheter or 50W/60ºC/8 mm catheter) without esophagus overlapping. The mean esophageal luminal temperature changes with versus without esophageal displacement were 0.11±0.13ºC versus 1.1±0.4ºC respectively, P<0.01. The radiofrequency had to be halted in 68% of the patients without esophageal displacement because of esophageal luminal temperature increase. There was no incidence of atrioesophageal fistula suspected or confirmed. Only two superficial bleeding caused by transesophageal echocardiography transducer insertion were observed. Conclusion Mechanical esophageal displacement by transesophageal echocardiography transducer during radiofrequency catheter ablation was able to prevent a rise in esophageal luminal temperature, helping to avoid esophageal thermal lesion. In most

  9. Simplified method for esophagus protection during radiofrequency catheter ablation of atrial fibrillation--prospective study of 704 cases.

    PubMed

    Mateos, José Carlos Pachón; Mateos, Enrique I Pachón; Peña, Tomas G Santillana; Lobo, Tasso Julio; Mateos, Juán Carlos Pachón; Vargas, Remy Nelson A; Pachón, Carlos Thiene C; Acosta, Juán Carlos Zerpa

    2015-01-01

    Although rare, the atrioesophageal fistula is one of the most feared complications in radiofrequency catheter ablation of atrial fibrillation due to the high risk of mortality. This is a prospective controlled study, performed during regular radiofrequency catheter ablation of atrial fibrillation, to test whether esophageal displacement by handling the transesophageal echocardiography transducer could be used for esophageal protection. Seven hundred and four patients (158 F/546M [22.4%/77.6%]; 52.8 ± 14 [17-84] years old), with mean EF of 0.66 ± 0.8 and drug-refractory atrial fibrillation were submitted to hybrid radiofrequency catheter ablation (conventional pulmonary vein isolation plus AF-Nests and background tachycardia ablation) with displacement of the esophagus as far as possible from the radiofrequency target by transesophageal echocardiography transducer handling. The esophageal luminal temperature was monitored without and with displacement in 25 patients. The mean esophageal displacement was 4 to 9.1cm (5.9 ± 0.8 cm). In 680 of the 704 patients (96.6%), it was enough to allow complete and safe radiofrequency delivery (30W/40ºC/irrigated catheter or 50W/60ºC/8 mm catheter) without esophagus overlapping. The mean esophageal luminal temperature changes with versus without esophageal displacement were 0.11 ± 0.13ºC versus 1.1 ± 0.4ºC respectively, P<0.01. The radiofrequency had to be halted in 68% of the patients without esophageal displacement because of esophageal luminal temperature increase. There was no incidence of atrioesophageal fistula suspected or confirmed. Only two superficial bleeding caused by transesophageal echocardiography transducer insertion were observed. Mechanical esophageal displacement by transesophageal echocardiography transducer during radiofrequency catheter ablation was able to prevent a rise in esophageal luminal temperature, helping to avoid esophageal thermal lesion. In most cases, the esophageal displacement was

  10. Alternate energy sources for catheter ablation.

    PubMed

    Wang, P J; Homoud, M K; Link, M S; Estes III, N A

    1999-07-01

    Because of the limitations of conventional radiofrequency ablation in creating large or linear lesions, alternative energy sources have been used as possible methods of catheter ablation. Modified radiofrequency energy, cryoablation, and microwave, laser, and ultrasound technologies may be able to create longer, deeper, and more controlled lesions and may be particularly suited for the treatment of ventricular tachycardias and for linear atrial ablation. Future studies will establish the efficacy of these new and promising technologies.

  11. Characteristics of atrial fibrillation cycle length predict restoration of sinus rhythm by catheter ablation.

    PubMed

    Di Marco, Luigi Yuri; Raine, Daniel; Bourke, John P; Langley, Philip

    2013-09-01

    Successful termination of atrial fibrillation (AF) during catheter ablation (CA) is associated with arrhythmia-free follow-up. Preablation factors such as mean atrial fibrillation cycle length (AFCL) predict the likelihood of AF termination during ablation but recurring patterns and AFCL stability have not been evaluated. To investigate novel predictors of acute and postoperative ablation outcomes from intracardiac electrograms: (1) recurring AFCL patterns and (2) localization index (LI) of the instantaneous fibrillatory rate distribution. Sixty-two patients with AF (32 paroxysmal AF; 45 men; age 57 ± 10 years) referred for CA were enrolled. One-minute electrogram was recorded from coronary sinus (CS; 5 bipoles) and right atrial appendage (HRA; 2 bipoles). Atrial activations were detected automatically to derive the AFCL and instantaneous fibrillatory rate (inverse of AFCL) time series. Recurring AFCL patterns were quantified by using recurrence plot indices (RPIs): percentage determinism, entropy of determinism, and maximum diagonal length. AFCL stability was determined by using the LI. The CA outcome predictivity of individual indices was assessed. Patients with terminated atrial fibrillation (T-AF) had higher RPI (P < .05 in CS7-8) and LI than did those with nonterminated atrial fibrillation (P < .005 in CS3-4; P < .05 in CS5-6, CS7-8, and HRA). Patients free of arrhythmia after 3-month follow-up had higher RPI and LI (all P < .05 in CS7-8). All indices except percentage determinism predicted T-AF in CS7-8 (area under the curve [AUC] ≥ 0.71; odds ratio [OR] ≥ 4.50; P < .05). The median AFCL and LI predicted T-AF in HRAD (AUC ≥ 0.75; OR ≥ 7.76; P < .05). The RPI and LI predicted 3-month follow-up in CS7-8 (AUC ≥ 0.68; OR ≥ 4.17; P < .05). AFCL recurrence and stability indices could be used in selecting patients more likely to benefit from CA. Copyright © 2013 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  12. Microembolism and catheter ablation I: a comparison of irrigated radiofrequency and multielectrode-phased radiofrequency catheter ablation of pulmonary vein ostia.

    PubMed

    Haines, David E; Stewart, Mark T; Dahlberg, Sarah; Barka, Noah D; Condie, Cathy; Fiedler, Gary R; Kirchhof, Nicole A; Halimi, Franck; Deneke, Thomas

    2013-02-01

    Cerebral diffusion-weighted MRI lesions have been observed after catheter ablation of atrial fibrillation. We hypothesized that conditions predisposing to microembolization could be identified using a porcine model of pulmonary vein ablation and an extracorporeal circulation loop. Ablations of the pulmonary veins were performed in 18 swine with echo monitoring. The femoral artery and vein were cannulated and an extracorporeal circulation loop with 2 ultrasonic bubble detectors and a 73-μm filter were placed in series. Microemboli and microbubbles were compared between ablation with an irrigated radiofrequency system (Biosense-Webster) and a phased radiofrequency multielectrode system (pulmonary vein ablation catheter [PVAC], Medtronic, Inc, Carlsbad, CA) in unipolar and 3 blended unipolar/bipolar modes. Animal pathology was examined. The size and number of microbubbles observed during ablation ranged from 30 to 180 μm and 0 to 3253 bubbles per ablation. Microbubble volumes with PVAC (29.1 nL) were greater than with irrigated radiofrequency (0.4 nL; P=0.045), and greatest with type II or III microbubbles on transesophageal echocardiography. Ablation with the PVAC showed fewest microbubbles in the unipolar mode (P=0.012 versus bipolar). The most occurred during bipolar energy delivery with overlap of proximal and distal electrodes (median microbubble volume, 1744 nL; interquartile range, 737-4082 nL; maximum, 19 516 nL). No cerebral MRI lesions were seen, but 2 animals had renal embolization. Left atrial ablation with irrigated radiofrequency and PVAC catheters in swine is associated with microbubble and microembolus production. Avoiding overlap of electrodes 1 and 10 on PVAC should reduce the microembolic burden associated with this procedure.

  13. Atrial Fibrillation Ablation and its Impact on Stroke.

    PubMed

    Graves, Kevin G; Jacobs, Victoria; May, Heidi T; Cutler, Michael J; Day, John D; Bunch, T Jared

    2018-01-24

    Atrial fibrillation (AF) is a commonly encountered arrhythmia, which is not yet fully understood. Catheter ablation has shown to be an effective strategy for rhythm management and several small or retrospective studies have shown that stroke rates are decreased in ablated AF patients compared to those medically managed. Several studies even show that ablation returns stroke risk to that of non-AF patients. Large scale, prospective trials will further illuminate this connection and provide mechanistic understanding of the role of the procedure versus the process of selection for the procedure and peri- and post-procedural therapy and management. Furthermore, modification of risk factors associated with AF show a significant increase in the sustained success of AF ablation and can also moderate the progression of AF.

  14. Does periprocedural anticoagulation management of atrial fibrillation affect the prevalence of silent thromboembolic lesion detected by diffusion cerebral magnetic resonance imaging in patients undergoing radiofrequency atrial fibrillation ablation with open irrigated catheters? Results from a prospective multicenter study.

    PubMed

    Di Biase, Luigi; Gaita, Fiorenzo; Toso, Elisabetta; Santangeli, Pasquale; Mohanty, Prasant; Rutledge, Neal; Yan, Xue; Mohanty, Sanghamitra; Trivedi, Chintan; Bai, Rong; Price, Justin; Horton, Rodney; Gallinghouse, G Joseph; Beheiry, Salwa; Zagrodzky, Jason; Canby, Robert; Leclercq, Jean François; Halimi, Franck; Scaglione, Marco; Cesarani, Federico; Faletti, Riccardo; Sanchez, Javier; Burkhardt, J David; Natale, Andrea

    2014-05-01

    Silent cerebral ischemia (SCI) has been reported in 14% of cases after catheter ablation of atrial fibrillation (AF) with radiofrequency (RF) energy and discontinuation of warfarin before AF ablation procedures. The purpose of this study was to determine whether periprocedural anticoagulation management affects the incidence of SCI after RF ablation using an open irrigated catheter. Consecutive patients undergoing RF ablation for AF without warfarin discontinuation and receiving heparin bolus before transseptal catheterization (group I, n = 146) were compared with a group of patients who had protocol deviation in terms of maintaining the therapeutic preprocedural international normalized ratio (patients with subtherapeutic INR) and/or failure to receive pretransseptal heparin bolus infusion and/or ≥2 consecutive ACT measurements <300 seconds (noncompliant population, group II, n = 134) and with a group of patients undergoing RF ablation with warfarin discontinuation bridged with low molecular weight heparin (group III, n = 148). All patients underwent preablation and postablation (within 48 hours) diffusion magnetic resonance imaging. SCI was detected in 2% of patients (3/146) in group I, 7% (10/134) in group II, and 14% (21/148) in group III (P <.001). "Therapeutic INR" was strongly associated with a lower prevalence of postprocedural silent cerebral ischemia (SCI). Multivariable analysis demonstrated nonparoxysmal AF (odds ratio 3.8, 95% confidence interval 1.5-9.7, P = .005) and noncompliance to protocol (odds ratio 2.8, 95% confidence interval 1.5-5.1, P <.001] to be significant predictors of ischemic events. Strict adherence to an anticoagulation protocol significantly reduces the prevalence of SCI after catheter ablation of AF with RF energy. Copyright © 2014 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  15. Efficacy and safety of cryoballoon ablation versus radiofrequency catheter ablation in atrial fibrillation: an updated meta-analysis

    PubMed Central

    Ma, Honglan; Sun, Dongdong; Luan, Hui; Feng, Wei; Zhou, Yaqiong; Wu, Jine; He, Caiyun

    2017-01-01

    Introduction Cryoballoon ablation (CBA) and irrigated radiofrequency catheter ablation (RFCA) are the main treatments for drug-refractory symptomatic atrial fibrillation (AF). Aim To compare the efficacy and safety between CBA and RFCA for the treatment of AF. Material and methods We searched the Embase and Medline databases for clinical studies published up to December 2016. Studies that satisfied our predefined inclusion criteria were included. Results After searching through the literature in the two major databases, 20 studies with a total of 9,141 patients were included in our study. The CBA had a significantly shorter procedure time (weighted mean difference (WMD) –30.38 min; 95% CI: –46.43 to –14.33, p = 0.0002) and non-significantly shorter fluoroscopy time (WMD –3.18 min; 95% CI: –6.43 to 0.07, p = 0.06) compared with RFCA. There was no difference in freedom from AF between CBA and RFCA (CBA 78.55% vs. RFCA 83.13%, OR = 1.15, 95% CI: 0.95–1.39, p = 0.14). The CBA was associated with a high risk of procedure-related complications (CBA 9.02% vs. RFCA 6.56%, OR = 1.56, 95% CI: 1.05–2.31, p = 0.03), especially phrenic nerve paralysis (PNP, OR = 10.72, 95% CI: 5.59–20.55, p < 0.00001). The risk of pericardial effusions/cardiac tamponade was low in the CBA group (CBA 1.05% vs. RFCA 1.86%, OR = 0.62, 95% CI: 0.41–0.93, p = 0.02). Conclusions For AF, CBA was as effective as RFCA. However, CBA had a shorter procedure time and a non-significantly shorter fluoroscopy time, a significantly high risk of PNP and a low incidence of pericardial effusions/cardiac tamponade compared with RFCA. PMID:29056997

  16. Echocardiographic predictors of atrial fibrillation recurrence after catheter ablation: A literature review.

    PubMed

    Liżewska-Springer, Aleksandra; Dąbrowska-Kugacka, Alicja; Lewicka, Ewa; Drelich, Łukasz; Królak, Tomasz; Raczak, Grzegorz

    2018-06-20

    Catheter ablation (CA) is a well-known treatment option for patients with symptomatic drug-resistant atrial fibrillation (AF). Multiple factors have been identified to determine AF recurrence after CA, however their predictive value is rather small. Identification of novel predictors of CA outcome is therefore of primary importance to reduce health costs and improve long-term results of this intervention. The recurrence of AF following CA is related to the severity of left ventricular (LV) dysfunction, extend of atrial dilatation and fibrosis. The aim of this paper was to present and discuss the latest studies on utility of echocardiographic parameters in terms of CA effectiveness in patients with paroxysmal and persistent AF. PubMed, Google Scholar, EBSCO databases were searched for studies reporting echocardiographic preprocedural predictors of AF recurrence after CA. LV systolic and diastolic function, as well as atrial size, strain and dyssynchrony were taken into consideration. Twenty one full-text articles were analyzed, including three meta-analyses. Several echocardiographic parameters have been reported to determine a risk of AF recurrence after CA. There are conventional methods that measure left atrial (LA) size and volume, LV ejection fraction, parameters assessing LV diastolic dysfunction, and methods using more innovative technologies based on speckle tracking echocardiography (STE) to determine LA synchrony and strain. Each of these parameters has its own predictive value. Regarding CA effectiveness, every patient has to be evaluated individually to estimate the risk of AF recurrence, optimally using a combination of several echocardiographic parameters.

  17. Radiofrequency catheter ablation of idiopathic ventricular arrhythmias originating from intramural foci in the left ventricular outflow tract: efficacy of sequential versus simultaneous unipolar catheter ablation.

    PubMed

    Yamada, Takumi; Maddox, William R; McElderry, H Thomas; Doppalapudi, Harish; Plumb, Vance J; Kay, G Neal

    2015-04-01

    Idiopathic ventricular arrhythmias (VAs) originating from the left ventricular outflow tract (LVOT) sometimes require catheter ablation from the endocardial and epicardial sides for their elimination, suggesting the presence of intramural VA foci. This study investigated the efficacy of sequential and simultaneous unipolar radiofrequency catheter ablation from the endocardial and epicardial sides in treating intramural LVOT VAs. Fourteen consecutive LVOT VAs, which required sequential or simultaneous irrigated unipolar radiofrequency ablation from the endocardial and epicardial sides for their elimination, were studied. The first ablation was performed at the site with the earliest local ventricular activation and best pace map on the endocardial or epicardial side. When the first ablation was unsuccessful, the second ablation was delivered on the other surface. If this sequential unipolar ablation failed, simultaneous unipolar ablation from both sides was performed. The first ablation was performed on the epicardial side in 9 VAs and endocardial side in 5 VAs. The intramural LVOT VAs were successfully eliminated by the sequential (n=9) or simultaneous (n=5) unipolar catheter ablation. Simultaneous ablation was most likely to be required for the elimination of the VAs when the distance between the endocardial and epicardial ablation sites was >8 mm and the earliest local ventricular activation time relative to the QRS onset during the VAs of <-30 ms was recorded at those ablation sites. LVOT VAs originating from intramural foci could usually be eliminated by sequential unipolar radiofrequency ablation and sometimes required simultaneous ablation from both the endocardial and epicardial sides. © 2015 American Heart Association, Inc.

  18. Catheter Ablation Versus Medical Rate Control in Atrial Fibrillation and Systolic Dysfunction: The CAMERA-MRI Study.

    PubMed

    Prabhu, Sandeep; Taylor, Andrew J; Costello, Ben T; Kaye, David M; McLellan, Alex J A; Voskoboinik, Aleksandr; Sugumar, Hariharan; Lockwood, Siobhan M; Stokes, Michael B; Pathik, Bhupesh; Nalliah, Chrishan J; Wong, Geoff R; Azzopardi, Sonia M; Gutman, Sarah J; Lee, Geoffrey; Layland, Jamie; Mariani, Justin A; Ling, Liang-Han; Kalman, Jonathan M; Kistler, Peter M

    2017-10-17

    Atrial fibrillation (AF) and left ventricular systolic dysfunction (LVSD) frequently co-exist despite adequate rate control. Existing randomized studies of AF and LVSD of varying etiologies have reported modest benefits with a rhythm control strategy. The goal of this study was to determine whether catheter ablation (CA) for AF could improve LVSD compared with medical rate control (MRC) where the etiology of the LVSD was unexplained, apart from the presence of AF. This multicenter, randomized clinical trial enrolled patients with persistent AF and idiopathic cardiomyopathy (left ventricular ejection fraction [LVEF] ≤45%). After optimization of rate control, patients underwent cardiac magnetic resonance (CMR) to assess LVEF and late gadolinium enhancement, indicative of ventricular fibrosis, before randomization to either CA or ongoing MRC. CA included pulmonary vein isolation and posterior wall isolation. AF burden post-CA was assessed by using an implanted loop recorder, and adequacy of MRC was assessed by using serial Holter monitoring. The primary endpoint was change in LVEF on repeat CMR at 6 months. A total of 301 patients were screened; 68 patients were enrolled between November 2013 and October 2016 and randomized with 33 in each arm (accounting for 2 dropouts). The average AF burden post-CA was 1.6 ± 5.0% at 6 months. In the intention-to-treat analysis, absolute LVEF improved by 18 ± 13% in the CA group compared with 4.4 ± 13% in the MRC group (p < 0.0001) and normalized (LVEF ≥50%) in 58% versus 9% (p = 0.0002). In those undergoing CA, the absence of late gadolinium enhancement predicted greater improvements in absolute LVEF (10.7%; p = 0.0069) and normalization at 6 months (73% vs. 29%; p = 0.0093). AF is an underappreciated reversible cause of LVSD in this population despite adequate rate control. The restoration of sinus rhythm with CA results in significant improvements in ventricular function, particularly in the absence of

  19. Catheter ablation as a treatment of atrioventricular block.

    PubMed

    Tuohy, Stephen; Saliba, Walid; Pai, Manjunath; Tchou, Patrick

    2018-01-01

    Symptomatic second-degree atrioventricular (AV) block is typically treated by implantation of a pacemaker. An otherwise healthy AV conduction system can nevertheless develop AV block due to interference from junctional extrasystoles. When present with a high burden, these can produce debilitating symptoms from AV block despite an underlying normal AV node and His-Purkinje system properties. The purpose of this study was to describe a catheter ablation approach for alleviating symptomatic AV block due to a ventricular nodal pathway interfering with AV conduction. Common clinical monitoring techniques such as Holter and event recorders were used. Standard electrophysiological study techniques using multipolar recording and ablation catheters were utilized during procedures. A 55-year-old woman presented with highly symptomatic, high-burden second-degree AV block due to concealed and manifest junctional premature beats. Electrophysiological characteristics indicated interference of AV conduction due to a concealed ventricular nodal pathway as the cause of the AV block. The patient's AV nodal and His-Purkinje system conduction characteristics were otherwise normal. Radiofrequency catheter ablation of the pathway was successful in restoring normal AV conduction and eliminating her clinical symptoms. Pathways inserting into the AV junction can interfere with AV conduction. When present at a high burden, this type of AV block can be highly symptomatic. Catheter ablation techniques can be used to alleviate this type of AV block and restore normal AV conduction. Copyright © 2017 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  20. Modeling and estimation of tip contact force for steerable ablation catheters.

    PubMed

    Khoshnam, Mahta; Skanes, Allan C; Patel, Rajni V

    2015-05-01

    The efficacy of catheter-based cardiac ablation procedures can be significantly improved if real-time information is available concerning contact forces between the catheter tip and cardiac tissue. However, the widely used ablation catheters are not equipped for force sensing. This paper proposes a technique for estimating the contact forces without direct force measurements by studying the changes in the shape of the deflectable distal section of a conventional 7-Fr catheter (henceforth called the "deflectable distal shaft," the "deflectable shaft," or the "shaft" of the catheter) in different loading situations. First, the shaft curvature when the tip is moving in free space is studied and based on that, a kinematic model for the deflectable shaft in free space is proposed. In the next step, the shaft shape is analyzed in the case where the tip is in contact with the environment, and it is shown that the curvature of the deflectable shaft provides useful information about the loading status of the catheter and can be used to define an index for determining the range of contact forces exerted by the ablation tip. Experiments with two different steerable ablation catheters show that the defined index can detect the range of applied contact forces correctly in more than 80% of the cases. Based on the proposed technique, a framework for obtaining contact force information by using the shaft curvature at a limited number of points along the deflectable shaft is constructed. The proposed kinematic model and the force estimation technique can be implemented together to describe the catheter's behavior before contact, detect tip/tissue contact, and determine the range of contact forces. This study proves that the flexibility of the catheter's distal shaft provides a means of estimating the force exerted on tissue by the ablation tip.

  1. Short-Term Heparin Kinetics during Catheter Ablation of Atrial Fibrillation.

    PubMed

    Gabus, Vincent; Rollin, Anne; Maury, Philippe; Forclaz, Andrei; Pascale, Patrizio; Dhutia, Harshil; Bisch, Laurence; Pruvot, Etienne

    2015-10-01

    Percutaneous catheter ablation of atrial fibrillation (CA-AF) is a treatment option for symptomatic drug-refractory atrial fibrillation (AF). CA-AF carries a risk for thromboembolic complications that has been minimized by the use of intraprocedural intravenous unfractionated heparin (UFH). The optimal administration of UFH as well as its kinetics are not well established and need to be precisely determined. A total 102 of consecutive patients suffering from symptomatic drug-refractory AF underwent CA-AF. The mean age was 61 ± 10 years old. After transseptal puncture of the fossa ovalis, weight-adjusted UFH bolus (100 U/kg) was infused. A significant increase in activated clotting time (ACT) was observed from an average value of 100 ± 27 seconds at baseline, to 355 ± 94 seconds at 10 min (T10), to 375 ± 90 seconds at 20 min (T20). Twenty-four patients failed to reach the targeted ACT value of ≥300 seconds at T10 and more than half of these remained with subtherapeutic ACT values at T20. This subset of patients showed similar clinical characteristics and amount of UFH but were more frequently prescribed preprocedural vitamin K1 than the rest of the study population. In a typical intervention setting, UFH displays unexpected slow anticoagulation kinetics in a significant proportion of procedures up to 20 minutes after infusion. These findings support the infusion of UFH before transseptal puncture or any left-sided catheterization with early ACT measurements to identify patients with delayed kinetics. They are in line with recent guidelines to perform CA-AF under therapeutic anticoagulation. © 2015 Wiley Periodicals, Inc.

  2. Low Left Atrial Compliance Contributes to the Clinical Recurrence of Atrial Fibrillation after Catheter Ablation in Patients with Structurally and Functionally Normal Heart.

    PubMed

    Park, Junbeom; Yang, Pil-sung; Kim, Tae-Hoon; Uhm, Jae-Sun; Kim, Joung-Youn; Joung, Boyoung; Lee, Moon-Hyoung; Hwang, Chun; Pak, Hui-Nam

    2015-01-01

    Stiff left atrial (LA) syndrome was initially reported in post-cardiac surgery patients and known to be associated with low LA compliance. We investigated the physiological and clinical implications of LA compliance by estimating LA pulse pressure (LApp) among patients with atrial fibrillation (AF) and structurally and functionally normal heart. Among 1038 consecutive patients with LA pressure measurements before AF ablation, we included 334 patients with structurally and functionally normal heart (81.7% male, 54.1±10.6 years, 77.0% paroxysmal AF) after excluding those with hypertension, diabetes, and previous ablation or cardiac surgery. We measured LApp (peak-nadir LA pressure) at the beginning of the ablation procedure and compared the values with clinical parameters and the AF recurrence rate. AF patients with normal heart were younger and more frequently male and had paroxysmal AF, a lower body mass index, and a lower LApp compared to others (all p<0.05). Based on the median value, the low LA compliance group (LApp≥13 mmHg) had a smaller LA volume index and lower LA voltage (all p<0.05) compared to the high LA compliance group. During a mean follow-up of 16.7±11.8 months, low LA compliance was independently associated with two fold-higher risk of clinical AF recurrence (HR:2.202; 95%CI:1.077-4.503; p = 0.031). Low LA compliance, as determined by an elevated LApp, was associated with a smaller LA volume index and lower LA voltage and independently associated with higher clinical recurrence after catheter ablation in AF patients with structurally and functionally normal heart.

  3. Catheter ablation of asymptomatic longstanding persistent atrial fibrillation: impact on quality of life, exercise performance, arrhythmia perception, and arrhythmia-free survival.

    PubMed

    Mohanty, Sanghamitra; Santangeli, Pasquale; Mohanty, Prasant; Di Biase, Luigi; Holcomb, Shawna; Trivedi, Chintan; Bai, Rong; Burkhardt, David; Hongo, Richard; Hao, Steven; Beheiry, Salwa; Santoro, Francesco; Forleo, Giovanni; Gallinghouse, Joseph G; Horton, Rodney; Sanchez, Javier E; Bailey, Shane; Hranitzky, Patrick M; Zagrodzky, Jason; Natale, Andrea

    2014-10-01

    Impact of catheter ablation on exercise performance, quality of life (QoL) and symptom perception in asymptomatic longstanding persistent AF (LSP-AF) patients has not been reported yet. Sixty-one consecutive patients (mean age 62 ±13 years, 71% males) with asymptomatic LSP-AF undergoing first catheter ablation were enrolled. Extended pulmonary vein antrum isolation plus ablation of complex fractionated atrial electrograms and nonpulmonary vein triggers was performed in all. QoL survey was taken at baseline and 12-months postablation, using Short Form-36 (SF-36). Information on arrhythmia perception was obtained using a standard questionnaire and corroborating symptoms with documented evidence of arrhythmia. Exercise tests were performed on 38 patients at baseline and 5 months after procedure. Recurrence was assessed using event recorder, cardiology evaluation, electrocardiogram, and 7-day holter monitoring. After 20 ± 5 months follow-up, 36 (57%) patients remained recurrence-free off-AAD. Of the 25 patients experiencing recurrence, 21 (84%) were symptomatic. Compared to baseline, follow-up SF-36 scores improved significantly in many measures. For patients with successful ablation, physical component summary (PCS) and mental component summary (MCS) demonstrated substantial improvement ( 64.2 ± 22.3 to 70.1 ± 18.6 [P = 0.041]; PCS: 62.6 ± 18.4 to 70.0 ± 14.4 [P = 0.032]). Postablation exercise study in recurrence-free patients showed significant reduction in resting and peak heart rate (75 ± 11 vs. 90 ± 17 and 132 ± 20 vs. 154.5 ± 36, respectively, P < 0.001), increase in peak oxygen pulse (13.4 ± 3 vs. 18.9 ± 16 mL/beat, Δ5.5 ± 15, P = 0.001), peak VO2 /kg (19.7 ± 5 to 23.4 ± 13 mL/kg/min [Δ 3.7 ± 10, P = 0.043]), and corresponding MET (5.6 ± 1 to 6.7 ± 4 [Δ1.1 ± 3, P = 0.03]). No improvement was observed in patients with failed procedures. Successful ablation improves exercise performance and QoL in asymptomatic LSP-AF patients. © 2014 Wiley

  4. Online Measurement of Microembolic Signal Burden by Transcranial Doppler during Catheter Ablation for Atrial Fibrillation-Results of a Multicenter Trial.

    PubMed

    von Bary, Christian; Deneke, Thomas; Arentz, Thomas; Schade, Anja; Lehrmann, Heiko; Fredersdorf, Sabine; Baldaranov, Dobri; Maier, Lars; Schlachetzki, Felix

    2017-01-01

    Left atrial pulmonary vein isolation (PVI) is an accepted treatment option for patients with symptomatic atrial fibrillation (AF). This procedure can be complicated by stroke or silent cerebral embolism. Online measurement of microembolic signals (MESs) by transcranial Doppler (TCD) may be useful for characterizing thromboembolic burden during PVI. In this prospective multicenter trial, we investigated the burden, characteristics, and composition of MES during left atrial catheter ablation using a variety of catheter technologies. PVI was performed in a total of 42 patients using the circular-shaped multielectrode pulmonary vein ablation catheter (PVAC) technology in 23, an irrigated radiofrequency (IRF) in 14, and the cryoballoon (CB) technology in 5 patients. TCD was used to detect the total MES burden and sustained thromboembolic showers (TESs) of >30 s. During TES, the site of ablation within the left atrium was registered. MES composition was classified manually into "solid," "gaseous," or "equivocal" by off-line expert assessment. The total MES burden was higher when using IRF compared to CB (2,336 ± 1,654 vs. 593 ± 231; p  = 0.007) and showed a tendency toward a higher burden when using IRF compared to PVAC (2,336 ± 1,654 vs. 1,685 ± 2,255; p  = 0.08). TES occurred more often when using PVAC compared to IRF (1.5 ± 2 vs. 0.4 ± 1.3; p  = 0.04) and most frequently when ablation was performed close to the left superior pulmonary vein (LSPV). Of the MES, 17.004 (23%) were characterized as definitely solid, 13.204 (18%) as clearly gaseous, and 44.366 (59%) as equivocal. We investigated the burden and characteristics of MES during left atrial catheter ablation for AF. All ablation techniques applied in this study generated a relevant number of MES. There was a significant difference in total MES burden using IRF compared to CB and a tendency toward a higher burden using IRF compared to PVAC. The highest TES burden was

  5. Respiratory motion influence on catheter contact force during radio frequency ablation procedures

    NASA Astrophysics Data System (ADS)

    Koch, Martin; Brost, Alexander; Hornegger, Joachim; Strobel, Norbert

    2013-03-01

    Minimally invasive catheter ablation is a common treatment option for atrial fibrillation. A common treatment strategy is pulmonary vein isolation. In this case, individual ablation points need to be placed around the ostia of the pulmonary veins attached to the left atrium to generate transmural lesions and thereby block electric signals. To achieve a durable transmural lesion, the tip of the catheter has to be stable with a sufficient tissue contact during radio-frequency ablation. Besides the steerable interface operated by the physician, the movement of the catheter is also influenced by the heart and breathing motion - particularly during ablation. In this paper we investigate the influence of breathing motion on different areas of the endocardium during radio frequency ablation. To this end, we analyze the frequency spectrum of the continuous catheter contact force to identify areas with increased breathing motion using a classification method. This approach has been applied to clinical patient data acquired during three pulmonary vein isolation procedures. Initial findings show that motion due to respiration is more pronounced at the roof and around the right pulmonary veins.

  6. Non-invasive prediction of catheter ablation outcome in persistent atrial fibrillation by fibrillatory wave amplitude computation in multiple electrocardiogram leads.

    PubMed

    Zarzoso, Vicente; Latcu, Decebal G; Hidalgo-Muñoz, Antonio R; Meo, Marianna; Meste, Olivier; Popescu, Irina; Saoudi, Nadir

    2016-12-01

    Catheter ablation (CA) of persistent atrial fibrillation (AF) is challenging, and reported results are capable of improvement. A better patient selection for the procedure could enhance its success rate while avoiding the risks associated with ablation, especially for patients with low odds of favorable outcome. CA outcome can be predicted non-invasively by atrial fibrillatory wave (f-wave) amplitude, but previous works focused mostly on manual measures in single electrocardiogram (ECG) leads only. To assess the long-term prediction ability of f-wave amplitude when computed in multiple ECG leads. Sixty-two patients with persistent AF (52 men; mean age 61.5±10.4years) referred for CA were enrolled. A standard 1-minute 12-lead ECG was acquired before the ablation procedure for each patient. F-wave amplitudes in different ECG leads were computed by a non-invasive signal processing algorithm, and combined into a mutivariate prediction model based on logistic regression. During an average follow-up of 13.9±8.3months, 47 patients had no AF recurrence after ablation. A lead selection approach relying on the Wald index pointed to I, V1, V2 and V5 as the most relevant ECG leads to predict jointly CA outcome using f-wave amplitudes, reaching an area under the curve of 0.854, and improving on single-lead amplitude-based predictors. Analysing the f-wave amplitude in several ECG leads simultaneously can significantly improve CA long-term outcome prediction in persistent AF compared with predictors based on single-lead measures. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  7. A Randomised Controlled Trial on the Effect of Nurse-Led Educational Intervention at the Time of Catheter Ablation for Atrial Fibrillation on Quality of Life, Symptom Severity and Rehospitalisation.

    PubMed

    Bowyer, John L; Tully, Phillip J; Ganesan, Anand N; Chahadi, Fahd K; Singleton, Cameron B; McGavigan, Andrew D

    2017-01-01

    Atrial Fibrillation (AF) is a common condition associated with impaired quality of life (QOL) and recurrent hospitalisation. Catheter ablation for AF is a well-established treatment for symptomatic patients despite medical therapy. We sought to examine the effect of point specific nurse-led education on QOL, AF symptomatology and readmission rate post AF ablation. Forty-one patients undergoing AF ablation were randomised to Nurse Intervention (NI) versus Control (C), n=22 vs. 19. Both groups were well matched with respect to age, sex and AF subtype. All patients completed SF36 and AF Symptom Checklist, Frequency and Severity Scale questionnaires at baseline and six months post ablation. The NI group underwent nurse education on admission, prior to discharge, and with telephone contact. Baseline SF-36 and AF Symptom Checklist, Frequency and Severity scores were similar. The NI group showed significant differences compared to Control with respect to higher QOL on the SF-36 score of Physical Functioning and Vitality at six months. There were significant improvements in seven components of the AF Symptom Checklist, Frequency and Severity at six months in the NI group with a trend in a further seven. There was no difference in AF related hospital readmissions at six months between C and NI groups (10.5% vs. 13.6%, p=ns). Nurse-led education at time of AF ablation is associated with improved QOL and reduced symptom frequency and severity compared to usual care. Copyright © 2016 Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). Published by Elsevier B.V. All rights reserved.

  8. Contact-force guided single-catheter approach for pulmonary vein isolation: Feasibility, outcomes, and cost-effectiveness.

    PubMed

    Pambrun, Thomas; Combes, Stéphane; Sousa, Pedro; Bloa, Mathieu Le; El Bouazzaoui, Rim; Grand-Larrieu, Delphine; Thompson, Nathaniel; Martin, Ruairidh; Combes, Nicolas; Boveda, Serge; Haïssaguerre, Michel; Albenque, Jean-Paul

    2017-03-01

    For conventional ablation of paroxysmal atrial fibrillation (AF), an ablation catheter in conjunction with a circular mapping catheter (CMC) is typically used for pulmonary vein isolation (PVI). The purpose of this study was to evaluate an approach for PVI with a single contact-force (CF) ablation catheter in terms of procedural reliability, outcomes, and cost-effectiveness. One hundred consecutive patients with paroxysmal AF were included in the study. Fifty patients (study group) underwent a CF-guided single-catheter approach, whereby PVI was demonstrated when sequential pacing at 9 equidistant points within the lesion set (carina included) failed to capture the left atrium. For confirmation, PVI was verified with a CMC. In comparison, 50 patients (control group) underwent a conventional PVI ablation guided by a CMC. Procedure time (101 ± 17 minutes vs 107 ± 15 minutes, P = .11), ablation time (24.2 ± 7.1 minutes vs 22.6 ± 8.8 minutes, P = .37), fluoroscopy time (5.6 ± 2.2 minutes vs 8.3 ± 3.4 minutes, P = .09), and applied CF (17.8 ± 2.6 g vs 18 ± 2.8 g, P = .72) did not reach statistical difference between the study and control groups. CF-guided single-catheter ablation achieved successful PVI in 98% of the study group and a 31% reduction in cost. At 1-year follow-up, sinus rhythm maintenance rate was similar in both groups (86% vs 84%, P = .78). In paroxysmal AF, a CF-guided single-catheter technique is an effective method for PVI, yielding substantial cost savings and clinical results similar to a conventional approach. Copyright © 2016 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  9. Radiofrequency catheter ablation of ventricular tachycardia in patients without structural heart disease.

    PubMed

    Klein, L S; Shih, H T; Hackett, F K; Zipes, D P; Miles, W M

    1992-05-01

    Radiofrequency energy has been used safely and successfully to eliminate accessory pathways in patients with the Wolff-Parkinson-White syndrome and the substrate for atrioventricular nodal reentrant tachycardia. However, this form of ablation has had only limited success in eliminating ventricular tachycardia in patients with structural heart disease. In contrast, direct-current catheter ablation has been used successfully to eliminate ventricular tachycardia in patients with and without structural heart disease. The purpose of this study was to test whether radiofrequency energy can safely and effectively ablate ventricular tachycardia in patients without structural heart disease. Sixteen patients (nine women and seven men; mean age, 38 years; range, 18-55 years) without structural heart disease who had ventricular tachycardia underwent radiofrequency catheter ablation to eliminate the ventricular tachycardia. Two patients presented with syncope, nine with presyncope, and five with palpitations only. Mean duration of symptoms was 6.7 years (range, 0.5-20 years). Radiofrequency catheter ablation successfully eliminated ventricular tachycardia in 15 of 16 patients (94%). Sites of ventricular tachycardia origin included the high right ventricular outflow tract (12 patients), the right ventricular septum near the tricuspid valve (three patients), and the left ventricular septum (one patient). The only ablation failure was in a patient whose ventricular tachycardia arose from a region near the His bundle. An accurate pace map, early local endocardial activation, and firm catheter contact with endocardium were associated with successful ablation. Radiofrequency ablation did not cause arrhythmias, produced minimal cardiac enzyme rise, and resulted in no detectable change in cardiac function by Doppler echocardiography. Radiofrequency catheter ablation of ventricular tachycardia in patients without structural heart disease is effective and safe and may be considered as

  10. Radiofrequency catheter ablation of Type 1 atrial flutter using a large-tip electrode catheter and high-power radiofrequency energy generator.

    PubMed

    Feld, Gregory K

    2004-11-01

    Recent studies have demonstrated a high degree of efficacy of 8 mm electrode-tipped or saline-irrigated-tip catheters for ablation of atrial flutter (AFL). These catheters have a theoretical advantage as they produce a large ablation lesion. However, large-tip ablation catheters have a larger surface area and require a higher power radiofrequency (RF) generator with up to 100 W capacity to produce adequate ablation temperatures (50-60 degrees C). The potential advantages of a large-tip ablation catheter and high-power RF generator include the need for fewer energy applications, shorter procedure and fluoroscopy times, and greater efficacy. Therefore, the safety and efficacy of AFL ablation using 8 or 10 mm electrode catheters and a 100-W RF generator was studied using the Boston Scientific, Inc., EPT-1000 XP cardiac ablation system. There were 169 patients, aged 61 +/- 12 years involved. Acute end points were bidirectional isthmus block and no inducible AFL. Following ablation, patients were seen at 1, 3 and 6 months, with event monitoring performed weekly and for any symptoms. Three quality of life surveys were completed during follow-up. Acute success was achieved in 158 patients (93%), with 12 +/- 11 RF energy applications. The efficacy of 8 and 10 mm electrodes did not differ significantly. The number of RF energy applications (10 +/- 8 vs. 14 +/- 8) and ablation time (0.5 +/- 0.4 vs. 0.8 +/- 0.6 h) were less with 10 mm compared with 8 mm electrodes (p < 0.01). Of 158 patients with acute success, 42 were not evaluated at 6 months due to study exclusions. Of the 116 patients evaluated at 6 months, 112 (97%) had no AFL recurrence. Of those without AFL recurrence at 6 months, 95 and 93% were free of symptoms at 12 and 24 months, respectively. Ablation of AFL improved quality of life scores (p < 0.05) and reduced anti-arrhythmic and rate control drug use (p < 0.05). Complications occurred in six out of 169 patients (3.6%) but there were no deaths. It was concluded

  11. The Effect of Atrial Fibrillation Ablation Techniques on P Wave Duration and P Wave Dispersion.

    PubMed

    Furniss, Guy O; Panagopoulos, Dimitrios; Kanoun, Sadeek; Davies, Edward J; Tomlinson, David R; Haywood, Guy A

    2018-02-14

    A reduction in surface electrocardiogram (ECG) P wave duration and dispersion is associated with improved outcomes in atrial fibrillation ablation. We investigated the effects of different ablation strategies on P wave duration and dispersion, hypothesising that extensive left atrial (LA) ablation with left atrial posterior wall isolation would give a greater reduction in P wave duration than more limited ablation techniques. A retrospective analysis of ECGs from patients who have undergone atrial fibrillation (AF) ablation was performed and pre-procedural sinus rhythm ECGs were compared with the post procedure ECGs. Maximal P wave duration was measured in leads I or II, minimum P wave duration in any lead and values were calculated for P wave duration and dispersion. Left atrial dimensions and medications at the time of ECG were documented. Ablation strategies compared were; pulmonary vein isolation (PVI) for paroxysmal atrial fibrillation (PAF) and the persistent AF (PsAF) ablation strategies of pulmonary vein isolation plus additional linear lesions (Lines), left atrial posterior wall isolation via catheter (PWI) and left atrial posterior wall isolation via staged surgical and catheter ablation (Hybrid). Sixty-nine patients' ECGs were analysed: 19 PVI, 21 Lines, 14 PWI, 15 Hybrid. Little correlation was seen between pre-procedure left atrial size and P wave duration (r=0.24) but LA size and P wave duration was larger in PsAF patients. A significant difference was seen in P wave reduction driven by Hybrid AF ablation (p<0.005) and Lines (<0.02). There was no difference amongst P wave dispersion between groups but the largest reduction was seen in the Hybrid ablation group. P wave duration increased with duration of continuous atrial fibrillation. Hybrid AF ablation significantly reduced P wave duration and dispersion compared to other ablation strategies including posterior wall isolation via catheter despite this being the same lesion set. Copyright © 2018

  12. Left atrial ejection force predicts the outcome after catheter ablation for paroxysmal atrial fibrillation.

    PubMed

    Kishima, Hideyuki; Mine, Takanao; Takahashi, Satoshi; Ashida, Kenki; Ishihara, Masaharu; Masuyama, Tohru

    2018-02-01

    Left atrium (LA) systolic dysfunction is observed in the early stages of atrial fibrillation (AF) prior to LA anatomical change. We investigated whether LA systolic dysfunction predicts recurrent AF after catheter ablation (CA) in patients with paroxysmal AF. We studied 106 patients who underwent CA for paroxysmal AF. LA systolic function was assessed with the LA emptying volume = Maximum LA volume (LAV max ) - Minimum LA volume (LAV min ), LA emptying fraction = [(LAV max - LAV min )/LAV max ] × 100, and LA ejection force calculated with Manning's method [LA ejection force = (0.5 × ρ × mitral valve area × A 2 )], where ρ is the blood density and A is the late-diastolic mitral inflow velocity. Recurrent AF was detected in 35/106 (33%) during 14.6 ± 9.1 months. Univariate analysis revealed reduced LA ejection force, decreased LA emptying fraction, larger LA diameter, and elevated brain natriuretic peptide as significant variables. On multivariate analysis, reduced LA ejection force and larger LA diameter were independently associated with recurrent AF. Moreover, patients with reduced LA ejection force and larger LA diameter had a higher risk of recurrent AF than preserved LA ejection force (log-rank P = 0.0004). Reduced LA ejection force and larger LA diameter were associated with poor outcome after CA for paroxysmal AF, and could be a new index to predict recurrent AF. © 2017 Wiley Periodicals, Inc.

  13. Prophylactic Catheter Ablation for the Prevention of Defibrillator Therapy

    PubMed Central

    Reddy, Vivek Y.; Reynolds, Matthew R.; Neuzil, Petr; Richardson, Allison W.; Taborsky, Milos; Jongnarangsin, Krit; Kralovec, Stepan; Sediva, Lucie; Ruskin, Jeremy N.; Josephson, Mark E.

    2008-01-01

    BACKGROUND For patients who have a ventricular tachyarrhythmic event, implantable cardioverter–defibrillators (ICDs) are a mainstay of therapy to prevent sudden death. However, ICD shocks are painful, can result in clinical depression, and do not offer complete protection against death from arrhythmia. We designed this randomized trial to examine whether prophylactic radiofrequency catheter ablation of arrhythmogenic ventricular tissue would reduce the incidence of ICD therapy. METHODS Eligible patients with a history of a myocardial infarction underwent defibrillator implantation for spontaneous ventricular tachycardia or fibrillation. The patients did not receive antiarrhythmic drugs. Patients were randomly assigned to defibrillator implantation alone or defibrillator implantation with adjunctive catheter ablation (64 patients in each group). Ablation was performed with the use of a substrate-based approach in which the myocardial scar is mapped and ablated while the heart remains predominantly in sinus rhythm. The primary end point was survival free from any appropriate ICD therapy. RESULTS The mortality rate 30 days after ablation was zero, and there were no significant changes in ventricular function or functional class during the mean (±SD) follow-up period of 22.5±5.5 months. Twenty-one patients assigned to defibrillator implantation alone (33%) and eight patients assigned to defibrillator implantation plus ablation (12%) received appropriate ICD therapy (antitachycardia pacing or shocks) (hazard ratio in the ablation group, 0.35; 95% confidence interval, 0.15 to 0.78, P = 0.007). Among these patients, 20 in the control group (31%) and 6 in the ablation group (9%) received shocks (P = 0.003). Mortality was not increased in the group assigned to ablation as compared with the control group (9% vs. 17%, P = 0.29). CONCLUSIONS In this randomized trial, prophylactic substrate-based catheter ablation reduced the incidence of ICD therapy in patients with a

  14. Three-Catheter Technique for Ablation of Left-Sided Accessory Pathways in Wolff-Parkinson-White is Less Expensive and Equally Successful When Compared to a Five-Catheter Technique.

    PubMed

    Capone, Christine A; Ceresnak, Scott R; Nappo, Lynn; Gates, Gregory J; Schechter, Clyde B; Pass, Robert H

    2015-12-01

    To compare the efficacy, safety, and cost-effectiveness of a three-catheter approach with a conventional five-catheter approach for the mapping and ablation of supraventricular tachycardia in pediatric patients with Wolff-Parkinson-White Syndrome (WPW) and concealed accessory pathways (APs). A retrospective review from 2008 to 2012 of patients less than 21 years with WPW who underwent a three-catheter radiofrequency (RF) ablation of a left-sided AP (ablation, right ventricular [RV] apical, and coronary sinus [CS] decapolar catheters) was performed. The three-catheter group was compared to a control group who underwent a standard five-catheter (ablation, RV apical, CS decapolar, His catheter, and right atrial catheter) ablation for the treatment of left-sided WPW or concealed AP. Demographics, ablation outcomes, and costs were compared between groups. Twenty-eight patients met inclusion criteria with 28 control patients. The groups did not differ in gender, age, weight, or body surface area. Locations of the AP on the mitral annulus were similar between the groups. All patients were ablated via transseptal approach. Note that 28 of 28 in the three-catheter group (100%) and 27 of 28 (96%) controls were acutely successfully ablated (P = 0.31). No complications were encountered. There was no difference in procedural time, time to loss of AP conduction, or number of RF applications. Use of the three-catheter technique resulted in a total savings of $2,465/case, which includes the $680 savings from using fewer catheters as well as the savings from a shortened procedure time. Ablation in patients with WPW and a left-sided AP can be performed using three catheters with similar efficacy and safety while offering significant cost savings compared to a conventional five-catheter approach. © 2015 Wiley Periodicals, Inc.

  15. A cost-utility analysis for catheter ablation of atrial fibrillation in combination with warfarin and dabigatran based on the CHADS2 score in Japan.

    PubMed

    Kimura, Takehiro; Igarashi, Ataru; Ikeda, Shunya; Nakajima, Kazuaki; Kashimura, Shin; Kunitomi, Akira; Katsumata, Yoshinori; Nishiyama, Takahiko; Nishiyama, Nobuhiro; Fukumoto, Kotaro; Tanimoto, Yoko; Aizawa, Yoshiyasu; Fukuda, Keiichi; Takatsuki, Seiji

    2017-01-01

    We aimed to clarify the cost-effectiveness of an expensive combination therapy for atrial fibrillation (AF) using both catheter ablation and dabigatran compared with warfarin at each CHADS 2 score for patients in Japan. A Markov model was constructed to analyze costs and quality-adjusted life years associated with AF therapeutic options with a time horizon of 10 years. The target population was 60-year-old patients with paroxysmal AF. The indication for anticoagulation was determined according to the Japanese guideline. Anticoagulation-related data were derived from the RE-LY study and the AF recurrence rate was set at 2.7% per month during the first 12 months and at 0.40% per month afterwards. Stroke risk was determined according to AF recurrence, anticoagulation, and CHADS 2 score. The risks for stroke recurrence and stroke death were also considered. Costs were calculated from the healthcare payer's perspective, and only direct medical costs were included. Warfarin was the most preferred option for patients with a CHADS 2 score of 0 from a health economics aspect. Ablation under warfarin was preferred for a CHADS 2 score of 1-3, while ablation under dabigatran was preferred for a CHADS 2 score ≥4. The quality of life score for AF had the largest impact on the incremental cost-effectiveness ratios in the analysis between the anticoagulation arm and the anticoagulation+ablation arm for a CHADS 2 score of 2. Within the range of the Japanese willingness-to-pay threshold (¥5,000,000), the ablation+warfarin arm became the best option with its probability of 81.7% for a CHADS 2 score of 2; the dabigatran+ablation arm was the most preferred option with its probability of 56.1% for a CHADS 2 score of 4. Ablation under dabigatran therapy is an expensive therapeutic option, but it might benefit patients with a low quality of life and a high CHADS 2 score. Copyright © 2016 Japanese College of Cardiology. Published by Elsevier Ltd. All rights reserved.

  16. Efficacy and Safety of Uninterrupted Low-Intensity Warfarin for Radiofrequency Catheter Ablation of Atrial Fibrillation in the Elderly.

    PubMed

    Xing, Yangbo; Xu, Buyun; Xu, Chao; Peng, Fang; Yang, Biao; Qiu, Yufang; Sun, Yong; Wang, Shengkai; Guo, Hangyuan

    2017-09-01

    No previous studies exist investigating the optimal intensity of uninterrupted anticoagulation with warfarin during radiofrequency catheter ablation (RFCA) for atrial fibrillation (AF) in the elderly. Evaluate the efficacy and safety of continuous low-intensity warfarin therapy throughout the periprocedural period of RFCA for AF in the elderly. This is a prospective randomized study. We enrolled AF patients (age ≥ 70 years) who underwent first-time RFCA for AF. Enrolled patients were randomized to group A and group B. The international normalized ratios before ablation were maintained at 1.5 to 2.0 and 2.0 to 2.5 in group A and B, respectively. Primary end points were periprocedural thromboembolic complications and major bleeding. Secondary end points included periprocedural asymptomatic cerebral emboli (ACE) and minor bleeding. A total of 101 patients were enrolled in our study (group A: 52; group B: 49). Baseline characteristics were well balanced between the 2 groups. Only 1 patient suffered from stroke in group B. No major bleeding events occurred in either group. The incidence of new ACE lesions was comparable between the 2 groups (11.5% vs 8.2%, P = 0.82). Minor bleeding occurred in 1 of 52 (1.9%) patients in group A and in 5 of 49 (10.2%) patients in group B ( P = 0.10). Uninterrupted low-intensity warfarin for RFCA of AF might be as effective as standard-intensity warfarin in preventing periprocedural thromboembolic complications and might be associated with fewer bleeding events in the elderly.

  17. The Role Of Contact Force In Atrial Fibrillation Ablation.

    PubMed

    Nakagawa, Hiroshi; Jackman, Warren M

    2014-01-01

    During radiofrequency (RF) ablation, low electrode-tissue contact force (CF) is associated with ineffective RF lesion formation, whereas excessive CF may increase the risk of steam pop and perforation. Recently, ablation catheters using two technologies have been developed to measure real-time catheter-tissue CF. One catheter uses three optical fibers to measure microdeformation of a deformable body in the catheter tip. The other catheter uses a small spring connecting the ablation tip electrode to the catheter shaft with a magnetic transmitter and sensors to measure microdeflection of the spring. Pre-clinical experimental studies have shown that 1) at constant RF power and application time, RF lesion size significantly increases with increasing CF; 2) the incidence of steam pop and thrombus also increase with increasing CF; 3) modulating RF power based on CF (i.e, high RF power at low CF and lower RF power at high CF) results in a similar and predictable RF lesion size. In clinical studies in patients undergoing pulmonary vein (PV) isolation, CF during mapping in the left atrium and PVs showed a wide range of CF and transient high CF. The most common high CF site was located at the anterior/rightward left atrial roof, directly beneath the ascending aorta. There was a poor relationship between CF and previously used surrogate parameters for CF (unipolar or bipolar atrial potential amplitude and impedance). Patients who underwent PV isolation with an average CF of <10 g experienced higher AF recurrence, whereas patients with ablation using an average CF of > 20g had lower AF recurrence. AF recurred within 12 months in 6 of 8 patients (75%) who had a mean Force-Time Integral (FTI, area under the curve for contact force vs. time) < 500 gs. In contrast, AF recurred in only 4 of 13 patients (21%) with ablation using a mean FTI >1000 gs. In another study, controlling RF power based on CF prevented steam pop and impedance rise without loss of lesion effectiveness. These

  18. Contact force monitoring during catheter ablation of intraatrial reentrant tachycardia in patients with congenital heart disease.

    PubMed

    Krause, Ulrich; Backhoff, David; Klehs, Sophia; Schneider, Heike E; Paul, Thomas

    2016-08-01

    Monitoring of catheter contact force during catheter ablation of atrial fibrillation has been shown to increase efficacy and safety. However, almost no data exists on the use of this technology in catheter ablation of intraatrial reentrant tachycardia in patients with congenital heart disease. The aim of the present study was to evaluate the impact of contact force monitoring during catheter ablation of intraatrial reentrant tachycardia in those patients. Catheter ablation of intraatrial reentrant tachycardia using monitoring of catheter contact force was performed in 28 patients with congenital heart disease (CHD). Thirty-two patients matched according to gender, age, and body weight with congenital heart disease undergoing catheter ablation without contact force monitoring served as control group. Parameters reflecting acute procedural success, long-term efficacy, and safety were compared. Acute procedural success was statistically not different in both groups (contact force 93 % vs. control 84 %, p = 0.3). Likewise the recurrence rate 1 year after ablation as shown by Kaplan-Meier analysis did not differ (contact force 28 % vs. control 37 %, p = 0.63). Major complications were restricted to groin vessel injuries and occurred in 3 out of 60 patients (contact force n = 1; control n = 2). Complications related to excessive catheter contact force were not observed. The present study did not show superiority of catheter contact force monitoring during ablation of intraatrial reentrant tachycardia in patients with CHD in terms of efficacy and safety. Higher contact force compared to pulmonary vein isolation might therefore be required to increase the efficacy of catheter ablation of intraatrial reentrant tachycardia in patients with congenital heart disease.

  19. Robotic navigation and ablation.

    PubMed

    Malcolme-Lawes, L; Kanagaratnam, P

    2010-12-01

    Robotic technologies have been developed to allow optimal catheter stability and reproducible catheter movements with the aim of achieving contiguous and transmural lesion delivery. Two systems for remote navigation of catheters within the heart have been developed; the first is based on a magnetic navigation system (MNS) Niobe, Stereotaxis, Saint-Louis, Missouri, USA, the second is based on a steerable sheath system (Sensei, Hansen Medical, Mountain View, CA, USA). Both robotic and magnetic navigation systems have proven to be feasible for performing ablation of both simple and complex arrhythmias, particularly atrial fibrillation. Studies to date have shown similar success rates for AF ablation compared to that of manual ablation, with many groups finding a reduction in fluoroscopy times. However, the early learning curve of cases demonstrated longer procedure times, mainly due to additional setup times. With centres performing increasing numbers of robotic ablations and the introduction of a pressure monitoring system, lower power settings and instinctive driving software, complication rates are reducing, and fluoroscopy times have been lower than manual ablation in many studies. As the demand for catheter ablation for arrhythmias such as atrial fibrillation increases and the number of centres performing these ablations increases, the demand for systems which reduce the hand skill requirement and improve the comfort of the operator will also increase.

  20. Left atrial thrombus and dense spontaneous echocardiographic contrast in patients on continuous direct oral anticoagulant therapy undergoing catheter ablation of atrial fibrillation: Comparison of dabigatran, rivaroxaban, and apixaban.

    PubMed

    Wu, Michael; Gabriels, James; Khan, Mohammad; Shaban, Nada; D'Amato, Salvatore; Liu, Christopher F; Markowitz, Steven M; Ip, James E; Thomas, George; Singh, Parmanand; Lerman, Bruce; Patel, Apoor; Cheung, Jim W

    2018-04-01

    Left atrial thrombus (LAT) and dense spontaneous echocardiographic contrast (SEC) detected by transesophageal echocardiography (TEE) in patients on continuous direct oral anticoagulants (DOAC) therapy before catheter ablation of atrial fibrillation (AF) or atrial flutter (AFL) have been described. We sought to compare rates of TEE-detected LAT and dense SEC among patients taking different DOACs. We evaluated 609 consecutive patients from 3 tertiary hospitals (median age 65 years; interquartile range 58-71 years; 436 (72%) men) who were on ≥4 weeks of continuous DOAC therapy (dabigatran, n = 166 [27%]; rivaroxaban, n = 257 [42%]; or apixaban, n = 186 [31%]) undergoing TEE before catheter ablation of AF/AFL. Demographic, clinical, and TEE data were collected for each patient. Despite ≥4 weeks of continuous DOAC therapy, 17 patients (2.8%) had LAT and 15 patients (2.5%) had dense SEC detected by TEE. The rates of LAT were 3.0%, 3.5%, and 1.6% for patients on dabigatran, rivaroxaban, and apixaban, respectively (P = .482). The rates of dense SEC were 1.2%, 3.5%, and 2.2% for patients on dabigatran, rivaroxaban, and apixaban, respectively (P = .299). Congestive heart failure (odds ratio 4.4; 95% confidence interval 1.6-12; P = .003) and moderate/severe left atrial enlargement (odds ratio 3.1; 95% confidence interval 1.1-8.6; P = .026) were independent predictors of LAT. In this study, ∼3% of patients on continuous DOAC therapy had LAT detected before catheter ablation of AF/AFL. Specific DOAC therapy did not significantly affect the rates of LAT detection. Copyright © 2017 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  1. Safety and efficacy of switching anticoagulation to aspirin three months after successful radiofrequency catheter ablation of atrial fibrillation.

    PubMed

    Uhm, Jae-Sun; Won, Hoyoun; Joung, Boyoung; Nam, Gi-Byoung; Choi, Kee-Joon; Lee, Moon-Hyoung; Kim, You-Ho; Pak, Hui-Nam

    2014-09-01

    Although current guidelines recommend continuing the same antithrombotic strategy regardless of rhythm control after radiofrequency catheter ablation (RFCA) of atrial fibrillation (AF), anticoagulation has a risk of major bleeding. We evaluated the safety of switching warfarin to aspirin in patients with successful AF ablation. Among 721 patients who underwent RFCA of AF, 608 patients (age, 57.3±10.9 years; 77.0% male, 75.5% paroxysmal AF) who had no evidence of AF recurrence at 3 months post-RFCA were included. We compared the thromboembolic and hemorrhagic events in patients for whom warfarin was switched to aspirin (ASA group; n=296) and patients who were kept on warfarin therapy (W group; n=312). There were no significant differences in CHA₂DS₂-VASc or HAS-BLED scores between the groups. In 30 patients in the ASA group and 37 patients in W group, AF recurred and warfarin was restarted or maintained during the 18.0±12.2 months of follow-up. There were no significant differences in thromboembolic (0.3% vs. 1.0%, p=0.342) and major bleeding incidences (0.7% vs. 0.6%, p=0.958) between ASA and W groups during the follow-up period. In the 259 patients with a CHA₂DS₂-VASc score≥2, there were no significant differences in thromboembolism (0.8% and 2.2%, p=0.380) or major bleeding incidences (0.8% and 1.4%, p=0.640) between ASA and W groups. Switching warfarin to aspirin 3 months after successful RFCA of AF could be as safe and efficacious as long-term anticoagulation even in patients with CHA₂DS₂-VASc score≥2. However, strict rhythm monitoring cannot be overemphasized.

  2. [Catheter ablation in patients with refractory cardiac arrhythmias with radiofrequency techniques].

    PubMed

    de Paola, A A; Balbão, C E; Silva Netto, O; Mendonça, A; Villacorta, H; Vattimo, A C; Souza, I A; Guiguer Júnior, N; Portugal, O P; Martinez Filho, E E

    1993-02-01

    evaluate the efficacy of radiofrequency catheter ablation in patients with refractory cardiac arrhythmias. twenty patients with refractory cardiac arrhythmias were undertaken to electrophysiologic studies for diagnosis and radiofrequency catheter ablation of their reentrant arrhythmias. Ten patients were men and 10 women with ages varying from 13 to 76 years (mean = 42.4 years). Nineteen patients had supraventricular tachyarrhythmias: One patient had atrial tachycardia and 1 atrial fibrillation with rapid ventricular rate, 5 patients had reentrant nodal tachycardia, 12 patients had reentrant atrioventricular tachycardia and 1 patient had right ventricular outflow tract tachycardia. the mean time of the procedure was 4.1 hours. The radiofrequency current energy applied was 40-50 V for 30-40 seconds. Ablation was successful in 18/20 (90%) patients; in 15/18 (83%) of successfully treated patients the same study was done for diagnosis and radiofrequency ablation. One patient had femoral arterial occlusion and was treated with no significant sequelae. During a mean follow-up of 4 months no preexcitation or reentrant tachycardia occurred. the results of our experience with radiofrequency catheter ablation of cardiac arrhythmias suggest that this technique can benefit an important number of patients with cardiac arrhythmias.

  3. Changes in Left Atrial Transport Function in Patients Who Maintained Sinus Rhythm After Successful Radiofrequency Catheter Ablation for Atrial Fibrillation: A 1-Year Follow-Up Multislice Computed Tomography Study.

    PubMed

    Kim, Jin-Seok; Im, Sung Il; Shin, Seung Yong; Kang, Jun Hyuk; Na, Jin Oh; Choi, Cheol Ung; Kim, Seong Hwan; Kim, Eung Ju; Rha, Seung-Woon; Park, Chang Gyu; Seo, Hong Seog; Oh, Dong Joo; Hwang, Chun; Kim, Young-Hoon; Yong, Hwan Seok; Lim, Hong Euy

    2017-02-01

    Functional remodeling of left atrium (LA) after radiofrequency catheter ablation (RFCA) for atrial fibrillation (AF) has not been fully elucidated. This study aimed to determine the impact of RFCA on LA transport function in patients who maintained sinus rhythm (SR) after AF ablation. A total of 96 patients (paroxysmal AF [PAF] = 52) who maintained SR during 1 year after AF ablation were enrolled. Multislice computed tomography was performed to determine LA volume (LAV) and LA emptying fraction (LAEF) at pre-RFCA and 1-year post-RFCA. Creatine kinase-MB (CK-MB) and troponin-T levels were analyzed 1-day post-RFCA. At 1-year post-RFCA, mean LAV and LAEF decreased in overall patients. Based on LAEF change (ΔLAEF) cutoff of 5.0%, LAEF reduced in 41 patients (worsened group) and improved or showed no change in 55 patients (preserved group). Compared with preserved group, worsened group had a higher proportion of PAF, higher levels of CK-MB and troponin-T, and additional LA ablation. ΔLAEF was inversely correlated with CK-MB and troponin-T levels. Subgroup analysis showed that LAEF significantly decreased in PAF patients who underwent additional LA ablation. Multivariate analysis revealed that high baseline LAEF and additional LA ablation were independent predictors for worsened LAEF. Although SR was maintained for 1 year after AF ablation, LAEF as well as LAV decreased. The extent of LAEF deterioration was significantly associated with the amount of iatrogenic myocardial damage. Our data indicate that extensive atrial ablation may lead to LA functional deterioration, especially in patients with PAF. © 2016 Wiley Periodicals, Inc.

  4. In vivo evaluation of virtual electrode mapping and ablation utilizing a direct endocardial visualization ablation catheter.

    PubMed

    Chik, William W B; Barry, M A; Malchano, Zach; Wylie, Bryan; Pouliopoulos, Jim; Huang, Kaimin; Lu, Juntang; Thavapalachandran, Sujitha; Robinson, David; Saadat, Vahid; Thomas, Stuart P; Ross, David L; Kovoor, Pramesh; Thiagalingam, Aravinda

    2012-01-01

    Radiofrequency (RF) ablation utilizing direct endocardial visualization (DEV) requires a "virtual electrode" to deliver RF energy while preserving visualization. This study aimed to: (1) examine the virtual electrode RF ablation efficacy; (2) determine the optimal power and duration settings; and (3) evaluate the utility of virtual electrode unipolar electrograms. The DEV catheter lesions were compared to lesions formed using a 3.5 mm open irrigated tip catheter within the right atria of 12 sheep. Generator power settings for DEV were titrated from 12W, 14W and 16W for 20, 30 and 40 seconds duration with 25 mL/min saline irrigation. Standard irrigated tip catheter settings of 30W, 50°C for 30 seconds and 30 mL/min were used. The DEV lesions were significantly greater in surface area and both major and minor axes compared to irrigated tip lesions (surface area 19.43 ± 9.09 vs 10.88 ± 4.72 mm, P<0.01) with no difference in transmurality (93/94 vs 46/47) or depth (1.86 ± 0.75 vs 1.85 ± 0.57 mm). Absolute electrogram amplitude reduction was greater for DEV lesions (1.89 ± 1.31 vs 1.49 ± 0.78 mV, P = 0.04), but no difference in percentage reduction. Pre-ablation pacing thresholds were not different between DEV (0.79 ± 0.36 mA) and irrigated tip (0.73 ± 0.25 mA) lesions. There were no complications noted during ablation with either catheter. Virtual electrode ablation consistently created wider lesions at lower power compared to irrigated tip ablation. Virtual electrode electrograms showed a comparable pacing and sensing efficacy in detecting local myocardial electrophysiological changes. © 2011 Wiley Periodicals, Inc.

  5. Mapping and isolation of the pulmonary veins using the PVAC catheter.

    PubMed

    Duytschaever, Mattias; Anne, Wim; Papiashvili, Giorgi; Vandekerckhove, Yves; Tavernier, Rene

    2010-02-01

    We aimed to investigate the feasibility, efficacy, and safety of the pulmonary vein ablation catheter (PVAC) catheter (a novel multielectrode catheter using duty-cycled bipolar and unipolar radiofrequency energy, Medtronic, Minneapolis, MN, USA) to completely isolate the pulmonary veins (PVs). Twenty-seven patients (60 +/- 8 years) with paroxysmal atrial fibrillation (AF) underwent PV isolation with the PVAC catheter. PVAC was used for both mapping and isolation of the PVs (PVAC-guided ablation). After PVAC ablation, presence/absence of PV potentials (PVP) was verified using a conventional circular mapping catheter. In case of residual PVP on the circular catheter, PVAC ablation was continued. After PVAC-guided ablation 99 of 106 PVs (93%) and 21 of 27 patients (78%) were proven to be isolated. Failure to isolate was due to a mapping failure in four right-sided PVs and a true ablation failure in three right-sided PVs. After continued PVAC ablation, 103 of 106 PVs (97%) and 25 of 27 patients (93%) were shown to be isolated. The total procedural time from femoral vein access to complete catheter withdrawal was 176 +/- 25 minutes. The actual dwelling-time of the PVAC within the left atrium was 102 +/- 37 minutes. Esophageal T degrees rise to >38.5 degrees occurred in nine of 19 monitored patients (47%). (1) PVAC-guided ablation (i.e., mapping and ablation with a single catheter) results in isolation of all PVs in 73% of the patients. (2) An additional circular mapping catheter is required to increase complete isolation rate to 93% of the patients. (3) Given the esophageal T degrees rise in almost 50% of patients, safety precautions are needed.

  6. Safety and Efficacy of Switching Anticoagulation to Aspirin Three Months after Successful Radiofrequency Catheter Ablation of Atrial Fibrillation

    PubMed Central

    Uhm, Jae-Sun; Won, Hoyoun; Joung, Boyoung; Nam, Gi-Byoung; Choi, Kee-Joon; Lee, Moon-Hyoung; Kim, You-Ho

    2014-01-01

    Purpose Although current guidelines recommend continuing the same antithrombotic strategy regardless of rhythm control after radiofrequency catheter ablation (RFCA) of atrial fibrillation (AF), anticoagulation has a risk of major bleeding. We evaluated the safety of switching warfarin to aspirin in patients with successful AF ablation. Materials and Methods Among 721 patients who underwent RFCA of AF, 608 patients (age, 57.3±10.9 years; 77.0% male, 75.5% paroxysmal AF) who had no evidence of AF recurrence at 3 months post-RFCA were included. We compared the thromboembolic and hemorrhagic events in patients for whom warfarin was switched to aspirin (ASA group; n=296) and patients who were kept on warfarin therapy (W group; n=312). Results There were no significant differences in CHA2DS2-VASc or HAS-BLED scores between the groups. In 30 patients in the ASA group and 37 patients in W group, AF recurred and warfarin was restarted or maintained during the 18.0±12.2 months of follow-up. There were no significant differences in thromboembolic (0.3% vs. 1.0%, p=0.342) and major bleeding incidences (0.7% vs. 0.6%, p=0.958) between ASA and W groups during the follow-up period. In the 259 patients with a CHA2DS2-VASc score ≥2, there were no significant differences in thromboembolism (0.8% and 2.2%, p=0.380) or major bleeding incidences (0.8% and 1.4%, p=0.640) between ASA and W groups. Conclusion Switching warfarin to aspirin 3 months after successful RFCA of AF could be as safe and efficacious as long-term anticoagulation even in patients with CHA2DS2-VASc score ≥2. However, strict rhythm monitoring cannot be overemphasized. PMID:25048480

  7. Pulmonary vein stenosis following catheter ablation of atrial fibrillation.

    PubMed

    Pürerfellner, Helmut; Martinek, Martin

    2005-11-01

    This review provides an update on the mechanisms, incidence, and current management of significant pulmonary vein stenosis following catheter ablation of atrial fibrillation. Catheter ablation involving the pulmonary veins and the surrounding left atrial tissue is increasingly used to treat atrial fibrillation. In parallel with the fact that these procedures may cure a substantial proportion of patients, severe complications have been observed. Pulmonary vein stenosis is a new clinical entity produced by radiofrequency energy delivery mainly within or at the orifice of the pulmonary veins. The exact incidence is currently unknown because the diagnosis is dependent on the imaging modality and on the rigor with which patients are followed up. The optimal method for screening patients has not been determined. Stenosis of a pulmonary vein may be assessed by combining anatomic and functional imaging using computed tomographic or magnetic resonance imaging, transesophageal echocardiography, and lung scanning. Symptoms vary considerably and may be misdiagnosed, leading to severe clinical consequences. Current treatment strategies involve pulmonary vein dilatation or stenting; however, the restenosis rate remains high. The long-term outcome in patients with pulmonary vein stenosis is unclear. Strategies under development to prevent pulmonary vein stenosis include alternate energy sources and modified ablation techniques. Pulmonary vein stenosis following catheter ablation is a new clinical entity that has been described in various reports recently. There is much uncertainty with respect to causative factors, incidence, diagnosis, and treatment, and long-term sequelae are unclear.

  8. First In Vivo Use of a Capacitive Micromachined Ultrasound Transducer Array–Based Imaging and Ablation Catheter

    PubMed Central

    Stephens, Douglas N.; Truong, Uyen T.; Nikoozadeh, Amin; Oralkan, Ömer; Seo, Chi Hyung; Cannata, Jonathan; Dentinger, Aaron; Thomenius, Kai; de la Rama, Alan; Nguyen, Tho; Lin, Feng; Khuri-Yakub, Pierre; Mahajan, Aman; Shivkumar, Kalyanam; O’Donnell, Matt; Sahn, David J.

    2012-01-01

    Objectives The primary objective was to test in vivo for the first time the general operation of a new multifunctional intracardiac echocardiography (ICE) catheter constructed with a microlinear capacitive micromachined ultrasound transducer (ML-CMUT) imaging array. Secondarily, we examined the compatibility of this catheter with electroanatomic mapping (EAM) guidance and also as a radiofrequency ablation (RFA) catheter. Preliminary thermal strain imaging (TSI)-derived temperature data were obtained from within the endocardium simultaneously during RFA to show the feasibility of direct ablation guidance procedures. Methods The new 9F forward-looking ICE catheter was constructed with 3 complementary technologies: a CMUT imaging array with a custom electronic array buffer, catheter surface electrodes for EAM guidance, and a special ablation tip, that permits simultaneous TSI and RFA. In vivo imaging studies of 5 anesthetized porcine models with 5 CMUT catheters were performed. Results The ML-CMUT ICE catheter provided high-resolution real-time wideband 2-dimensional (2D) images at greater than 8 MHz and is capable of both RFA and EAM guidance. Although the 24-element array aperture dimension is only 1.5 mm, the imaging depth of penetration is greater than 30 mm. The specially designed ultrasound-compatible metalized plastic tip allowed simultaneous imaging during ablation and direct acquisition of TSI data for tissue ablation temperatures. Postprocessing analysis showed a first-order correlation between TSI and temperature, permitting early development temperature-time relationships at specific myocardial ablation sites. Conclusions Multifunctional forward-looking ML-CMUT ICE catheters, with simultaneous intracardiac guidance, ultrasound imaging, and RFA, may offer a new means to improve interventional ablation procedures. PMID:22298868

  9. Impact of esophageal temperature monitoring guided atrial fibrillation ablation on preventing asymptomatic excessive transmural injury

    PubMed Central

    Kiuchi, Kunihiko; Okajima, Katsunori; Shimane, Akira; Kanda, Gaku; Yokoi, Kiminobu; Teranishi, Jin; Aoki, Kousuke; Chimura, Misato; Toba, Takayoshi; Oishi, Shogo; Sawada, Takahiro; Tsukishiro, Yasue; Onishi, Tetsuari; Kobayashi, Seiichi; Taniguchi, Yasuyo; Yamada, Shinichiro; Yasaka, Yoshinori; Kawai, Hiroya; Yoshida, Akihiro; Fukuzawa, Koji; Itoh, Mitsuaki; Imamura, Kimitake; Fujiwara, Ryudo; Suzuki, Atsushi; Nakanishi, Tomoyuki; Yamashita, Soichiro; Hirata, Ken-ichi; Tada, Hiroshi; Yamasaki, Hiro; Naruse, Yoshihisa; Igarashi, Miyako; Aonuma, Kazutaka

    2015-01-01

    Background Even with the use of a reduced energy setting (20–25 W), excessive transmural injury (ETI) following catheter ablation of atrial fibrillation (AF) is reported to develop in 10% of patients. However, the incidence of ETI depends on the pulmonary vein isolation (PVI) method and its esophageal temperature monitor setting. Data comparing the incidence of ETI following AF ablation with and without esophageal temperature monitoring (ETM) are still lacking. Methods This study was comprised of 160 patients with AF (54% paroxysmal, mean: 24.0±2.9 kg/m2). Eighty patients underwent ablation accompanied by ETM. The primary endpoint was defined as the occurrence of ETI assessed by endoscopy within 5 d after the AF ablation. The secondary endpoint was defined as AF recurrence after a single procedure. If the esophageal temperature probe registered >39 °C, the radiofrequency (RF) application was stopped immediately. RF applications could be performed in a point-by-point manner for a maximum of 20 s and 20 W. ETI was defined as any injury that resulted from AF ablation, including esophageal injury or periesophageal nerve injury (peri-ENI). Results The incidence of esophageal injury was significantly lower in patients whose AF ablation included ETM compared with patients without ETM (0 [0%] vs. 6 [7.5%], p=0.028), but not the incidence of peri-ENI (2 [2.5%] vs. 3 [3.8%], p=1.0). AF recurrence 12 months after the procedure was similar between the groups (20 [25%] in the ETM group vs. 19 [24%] in the non-ETM group, p=1.00). Conclusions Catheter ablation using ETM may reduce the incidence of esophageal injury without increasing the incidence of AF recurrence but not the incidence of peri-ENI. PMID:26949429

  10. Long-term outcome of catheter ablation in atrial fibrillation patients with coexistent metabolic syndrome and obstructive sleep apnea: impact of repeat procedures versus lifestyle changes.

    PubMed

    Mohanty, Sanghamitra; Mohanty, Prasant; DI Biase, Luigi; Bai, Rong; Trivedi, Chintan; Santangeli, Pasquale; Santoro, Francesco; Hongo, Richard; Hao, Steven; Beheiry, Salwa; Burkhardt, David; Gallinghouse, Joseph G; Horton, Rodney; Sanchez, Javier E; Bailey, Shane; Hranitzky, Patrick M; Zagrodzky, Jason; Natale, Andrea

    2014-09-01

    Metabolic syndrome (MS) and obstructive sleep apnea (OSA) are well-known independent risk factors for atrial fibrillation (AF) recurrence. This study evaluated ablation outcome in AF patients with coexistent MS and OSA and influence of lifestyle modifications (LSM) on arrhythmia recurrence. We included 1,257 AF patients undergoing first catheter ablation (30% paroxysmal AF). Patients having MS + OSA were classified into Group 1 (n = 126; 64 ± 8 years; 76% male). Group 2 (n = 1,131; 62 ± 11 years; 72% male) included those with either MS (n = 431) or OSA (n = 112; no CPAP users) or neither of these comorbidities (n = 588). Patients experiencing recurrence after first procedure were divided into 2 subgroups; those having sporadic events (frequency < 2 months) remained on previously ineffective antiarrhythmic drugs (AAD) and aggressive LSM, while those with persistent arrhythmia (incessant or ≥2 months) underwent repeat ablation. After 34 ± 8 months of first procedure, 66 (52%) in Group 1 and 386 (34%) in Group 2 had recurrence (P < 0.001). Recurrence rate in only-MS, only-OSA, and without MS/OSA groups were 40%, 38%, and 29%, respectively. Patients with MS + OSA experienced substantially higher recurrence compared to those with lone MS or OSA (52% vs. 40% vs. 38%; P = 0.036). Of the 452 patients having recurrence, 250 underwent redo-ablation and 194 remained on AAD and LSM. At 20 ± 6 months, 76% of the redo group remained arrhythmia-free off AAD whereas 74% of the LSM group were free from recurrence (P = 0.71), 33% of which were off AAD. MS and OSA have additive negative effect on arrhythmia recurrence following single procedure. Repeat ablation or compliant LSM increase freedom from recurrent AF. © 2014 Wiley Periodicals, Inc.

  11. Interatrial block and interatrial septal thickness in patients with paroxysmal atrial fibrillation undergoing catheter ablation: Long-term follow-up study.

    PubMed

    Gul, Enes E; Pal, Raveen; Caldwell, Jane; Boles, Usama; Hopman, Wilma; Glover, Benedict; Michael, Kevin A; Redfearn, Damian; Simpson, Chris; Abdollah, Hoshiar; Baranchuk, Adrian

    2017-07-01

    Interatrial block (IAB) is a strong predictor of recurrence of atrial fibrillation (AF). IAB is a conduction delay through the Bachman region, which is located in the upper region of the interatrial space. During IAB, the impulse travels from the right atrium to the interatrial septum (IAS) and coronary sinus to finally reach the left atrium in a caudocranial direction. No relation between the presence of IAB and IAS thickness has been established yet. To determine whether a correlation exists between the degree of IAB and the thickness of the IAS and to determine whether IAS thickness predicts AF recurrence. Sixty-two patients with diagnosis of paroxysmal AF undergoing catheter ablation were enrolled. IAB was defined as P-wave duration ≥120 ms. IAS thickness was measured by cardiac computed tomography. Among 62 patients with paroxysmal AF, 45 patients (72%) were diagnosed with IAB. Advanced IAB was diagnosed in 24 patients (39%). Forty-seven patients were male. During a mean follow-up period of 49.8 ± 22 months (range 12-60 months), 32 patients (51%) developed AF recurrence. IAS thickness was similar in patients with and without IAB (4.5 ± 2.0 mm vs. 4.0 ± 1.4 mm; p = .45) and did not predict AF. Left atrial size was significantly enlarged in patients with IAB (40.9 ± 5.7 mm vs. 37.2 ± 4.0 mm; p = .03). Advanced IAB predicted AF recurrence after the ablation (OR: 3.34, CI: 1.12-9.93; p = .03). IAS thickness was not significantly correlated to IAB and did not predict AF recurrence. IAB as previously demonstrated was an independent predictor of AF recurrence. © 2016 Wiley Periodicals, Inc.

  12. Radiofrequency catheter ablation in patients with symptomatic atrial flutter/tachycardia after orthotopic heart transplantation.

    PubMed

    Li, Yi-gang; Grönefeld, Gerian; Israel, Carsten; Lu, Shang-biao; Wang, Qun-shan; Hohnloser, Stefan H

    2006-12-20

    Atrial tachycardia or flutter is common in patients after orthotopic heart transplantation. Radiofrequency catheter ablation to treat this arrhythmia has not been well defined in this setting. This study was conducted to assess the incidence of various symptomatic atrial arrhythmias and the efficacy and safety of radiofrequency catheter ablation in these patients. Electrophysiological study and catheter ablation were performed in patients with symptomatic tachyarrhythmia. One Halo catheter with 20 poles was positioned around the tricuspid annulus of the donor right atrium, or positioned around the surgical anastomosis when it is necessary. Three quadripolar electrode catheters were inserted via the right or left femoral vein and positioned in the recipient atrium, the bundle of His position, the coronary sinus. Programmed atrial stimulation and burst pacing were performed to prove electrical conduction between the recipient and the donor atria and to induce atrial arrhythmias. Out of 55 consecutive heart transplantation patients, 6 males [(58 +/- 12) years] developed symptomatic tachycardias at a mean of (5 +/- 4) years after heart transplantation. Electrical propagation through the suture line between the recipient and the donor atrium was demonstrated during atrial flutter or during recipient atrium and donor atrium pacing in 2 patients. By mapping around the suture line, the earliest fragmented electrogram of donor atrium was assessed. This electrical connection was successfully ablated in the anterior lateral atrium in both patients. There was no electrical propagation through the suture line in the other 4 patients. Two had typical atrial flutter in the donor atrium which was successfully ablated by completing a linear ablation between the tricuspid annulus and the inferior vena cava. Two patients had atrial tachycardia which was ablated in the anterior septal and lateral donor atrium. There were no procedure-related complications. Patients were free of

  13. Impact of Catheter Ablation for Paroxysmal Atrial Fibrillation in Patients With Sick Sinus Syndrome - Important Role of Non-Pulmonary Vein Foci.

    PubMed

    Hayashi, Kentaro; Fukunaga, Masato; Yamaji, Kyohei; An, Yoshimori; Nagashima, Michio; Hiroshima, Kenichi; Ohe, Masatsugu; Makihara, Yu; Yamashita, Kennosuke; Ando, Kenji; Iwabuchi, Masashi; Goya, Masahiko

    2016-01-01

    The clinical efficacy of catheter ablation (CA) for paroxysmal atrial fibrillation (PAF) in patients with sick sinus syndrome (SSS) and the mechanism and predictors of recurrence are not yet completely elucidated. Of 963 consecutive patients who underwent PAF ablation during the study period, a total of 108 patients with SSS (SSS group) and 108 matched controls without SSS (non-SSS group) were followed up. During the follow-up period (mean, 32.8±17.5 months), the SSS group had significantly higher AF recurrence rate since the last procedure than the non-SSS group (26.9% vs. 12.0%; P=0.02). The SSS group had significantly higher prevalence of non-pulmonary vein (non-PV) foci than the non-SSS group (25.9% vs. 13.9%; P=0.027). On multivariate analysis congestive heart failure (HR, 13.7; 95% CI: 1.57-119; P=0.02) and non-PV foci (HR, 5.75; 95% CI: 1.69-19.6; P=0.005) were independent predictors of recurrence following CA in the SSS group. In the SSS group, 88 patients had bradycardia-tachycardia syndrome without prior permanent pacemaker implantation. Of these, 6 required pacemaker implantation because of AF and sinus pause recurrence. Patients with SSS are at higher risk of AF recurrence after CA. Non-PV foci are associated with AF recurrence following PAF with SSS.

  14. A novel four-wire-driven robotic catheter for radio-frequency ablation treatment.

    PubMed

    Yoshimitsu, Kitaro; Kato, Takahisa; Song, Sang-Eun; Hata, Nobuhiko

    2014-09-01

       Robotic catheters have been proposed to increase the efficacy and safety of the radio-frequency ablation treatment. The robotized motion of current robotic catheters mimics the motion of manual ones-namely, deflection in one direction and rotation around the catheter. With the expectation that the higher dexterity may achieve further efficacy and safety of the robotically driven treatment, we prototyped a four-wire-driven robotic catheter with the ability to deflect in two- degree-of-freedom motions in addition to rotation.    A novel quad-directional structure with two wires was designed and developed to attain yaw and pitch motion in the robotic catheter. We performed a mechanical evaluation of the bendability and maneuverability of the robotic catheter and compared it with current manual catheters.    We found that the four-wire-driven robotic catheter can achieve a pitching angle of 184.7[Formula: see text] at a pulling distance of wire for 11 mm, while the yawing angle was 170.4[Formula: see text] at 11 mm. The robotic catheter could attain the simultaneous two- degree-of-freedom motions in a simulated cardiac chamber.    The results indicate that the four-wire-driven robotic catheter may offer physicians the opportunity to intuitively control a catheter and smoothly approach the focus position that they aim to ablate.

  15. Selective Angiography Using the Radiofrequency Catheter: An Alternative Technique for Mapping and Ablation in the Aortic Cusps.

    PubMed

    Roca-Luque, Ivo; Rivas, Nuria; Francisco, Jaume; Perez, Jordi; Acosta, Gabriel; Oristrell, Gerard; Terricabres, Maria; Garcia-Dorado, David; Moya, Angel

    2017-01-01

    Ablation in aortic cusps could be necessary in up to 15% of the patients, especially in para-Hisian atrial tachycardia and ventricular arrhythmias arising from outflow tracts. Risk of coronary damage has led to recommendation of systematic coronary angiography (CA) during the procedure. Other image tests as intravascular (ICE) or transesophageal echocardiography (TEE) have been proposed. Both methods have limitations: additional vascular access for ICE and need for additional CA in some patients in case of TEE. We describe an alternative method to assess relation of catheter tip and coronary ostia during ablation in aortic cusps without additional vascular accesses by performing selective angiography with the ablation catheter. We prospectively evaluated 12 consecutive patients (69.3 ± 8.5, 6 female) who underwent ablation in right (1), left (5), and noncoronary cusps (6). We performed angiography through the ablation cooled tip radiofrequency catheter at the ablation site. Ablation was effective in 91.6% of the patients (3 patients needed additional ablation out of coronary cusps: pulmonary cusp, right ventricular outflow tract (RVOT), and coronary sinus and 1 patient underwent a second procedure because recurrence). No complications occurred neither during procedure nor follow-up (6.2 ± 3.8 months). No technical problems occurred with the ablation catheter after contrast injection. Selective angiography through a cooled-tip radiofrequency ablation catheter is feasible to assess relation of coronary ostia and ablation site when ablation in aortic cusps. It allows continuous real-time assessment of this relation, avoids the need for additional vascular accesses and no complications occurred in our series. © 2016 Wiley Periodicals, Inc.

  16. The Impact of Transforming Growth Factor-β1 Level on Outcome After Catheter Ablation in Patients With Atrial Fibrillation.

    PubMed

    Kishima, Hideyuki; Mine, Takanao; Takahashi, Satoshi; Ashida, Kenki; Ishihara, Masaharu; Masuyama, Tohru

    2017-04-01

    Transforming growth factor-β 1 (TGF-β 1 ) is an important factor that induces atrial fibrosis and atrial fibrillation (AF). The purpose of this study was to evaluate the association between TGF-β 1 level and clinical factors before catheter ablation (CA), and to investigate the impact of TGF-β 1 level on the outcome after CA for AF. This prospective study included 151 patients (persistent AF group: n = 59, paroxysmal AF [PAF] group: n = 54, and control group: n = 38). All patients who underwent CA for AF were followed up for 12 months. The PAF group had the highest TGF-β 1 levels in all patients. An early recurrence of AF (ERAF: defined as episodes of atrial tachyarrhythmia within a 3-month blanking period) was detected in 60 patients (53%). Recurrent AF after the blanking period was detected in 36 patients (32%). On multivariate analysis, low TGF-β 1 level was the only independent factor associated with recurrent AF. Moreover, the AF recurrence ratio was higher in the low TGF-β 1 group (< 12.56 ng/mL) than in the high TGF-β 1 group (16 of 29 patients, 55% vs. 20 of 84 patients, 24%, P = 0.002 by log-rank test). PAF was associated with a higher TGF-β 1 level. Moreover, lower TGF-β 1 level in AF patients could be a cause of recurrent AF after CA. © 2017 Wiley Periodicals, Inc.

  17. A Novel Microwave Catheter Can Perform Noncontact Circumferential Endocardial Ablation in a Model of Pulmonary Vein Isolation.

    PubMed

    Qian, Pierre; Barry, Michael Anthony; Nguyen, Trang; Ross, David; Kovoor, Pramesh; McEwan, Alistair; Thomas, Stuart; Thiagalingam, Aravinda

    2015-07-01

    Pulmonary vein isolation is an effective treatment for atrial fibrillation. Current endocardial ablation techniques require catheter contact for lesion formation. Inadequate or inconsistent catheter contact results in difficulty with achieving acute and long-term isolation and consequent atrial arrhythmia recurrence. Microwave energy produces radiant heating and therefore can be used for noncontact catheter ablation. We hypothesized that it is possible to design a microwave catheter to produce a circumferential transmural thermal lesion in an in vitro model of a pulmonary vein antrum. A monopole microwave catheter with a sideways firing axially symmetrical heating pattern was designed. Noncontact ablations were performed in a perfused pulmonary vein model constructed from microwave myocardial phantom embedded with a sheet of thermochromic liquid crystal to permit visualization and measurement of thermal lesions from color changes. 1200 J ablations were performed at 150 W for 80 seconds and 120 W for 100 seconds at high (0.8 L/min) and low (0.06 L/min) flow through the modeled pulmonary vein. Myocardial tissue was substituted for the phantom material and ablations repeated at 150 W for 180 seconds and stained with nitro-blue tetrazolium. The catheter was able to induce deep circumferential antral lesions in myocardial phantom and myocardial tissue. Higher power and shorter ablations delivering the same amount of microwave energy resulted in larger lesions with less surface sparing. A microwave catheter can be designed to produce a circumferential thermal lesion on noncontact ablation and may have possible applications for pulmonary vein isolation. © 2015 Wiley Periodicals, Inc.

  18. Treatment of Atrial Fibrillation By The Ablation Of Localized Sources

    PubMed Central

    Narayan, Sanjiv M.; Krummen, David E.; Shivkumar, Kalyanam; Clopton, Paul; Rappel, Wouter-Jan; Miller, John M.

    2012-01-01

    Objectives We hypothesized that human atrial fibrillation (AF) may be sustained by localized sources (electrical rotors and focal impulses), whose elimination (Focal Impulse and Rotor Modulation, FIRM) may improve outcome from AF ablation. Background Catheter ablation for AF is a promising therapy, whose success is limited in part by uncertainty in the mechanisms that sustain AF. We developed a computational approach to map whether AF is sustained by several meandering waves (the prevailing hypothesis) or localized sources, then prospectively tested whether targeting patient-specific mechanisms revealed by mapping would improve AF ablation outcome. Methods We recruited 92 individuals during 107 consecutive ablation procedures for paroxysmal or persistent (72%) AF. Cases were prospectively treated, in a 2-arm 1:2 design, by ablation at sources (FIRM-Guided) followed by conventional ablation (n=36), or conventional ablation alone (n=71; FIRM-Blinded). Results Localized rotors or focal impulses were detected in 98 (97%) of 101 cases with sustained AF, each exhibiting 2.1±1.0 sources. The acute endpoint (AF termination or consistent slowing) was achieved in 86% of FIRM-guided versus 20% of FIRM-Blinded cases (p<0.001). FIRM ablation alone at the primary source terminated AF in 2.5 minutes (median; IQR 1.0–3.1). Total ablation time did not differ between groups (57.8±22.8 versus 52.1±17.8 minutes, p=0.16). During 273 days (median; IQR 132–681 days) after a single procedure, FIRM-Guided cases had higher freedom from AF (82.4% versus 44.9%; p<0.001) after a single procedure than FIRM-blinded cases with rigorous, often implanted, ECG monitoring. Adverse events did not differ between groups. CONCLUSIONS Localized electrical rotors and focal impulse sources are prevalent sustaining-mechanisms for human AF. FIRM ablation at patient-specific sources acutely terminated or slowed AF, and improved outcome. These results offer a novel mechanistic framework and treatment

  19. Single-ring ablation compared with standard circumferential pulmonary vein isolation using remote magnetic catheter navigation.

    PubMed

    Sohns, Christian; Bergau, Leonard; Seegers, Joachim; Lüthje, Lars; Vollmann, Dirk; Zabel, Markus

    2014-10-01

    In ablation of atrial fibrillation, the single-ring method aims for isolation of the posterior wall of the left atrium (LA) including the pulmonary veins (PVs) but avoiding posterior LA lesions. The aim of this randomized prospective study was to evaluate safety and efficacy of remote magnetic navigation (RMN)-guided single-ring ablation strategy as compared to standard RMN-guided circumferential PV ablation (PVA). Eighty consecutive patients undergoing PVA were enrolled prospectively and randomized equally into two study groups. RMN using the Stereotaxis system and open-irrigated 3.5-mm ablation catheters were used with a 3D mapping system in all procedures. Forty patients underwent RMN-guided single-ring ablation, and 40 patients received RMN-guided circumferential PVA. In the circumferential group, 3.3 ± 1.1 PVs were successfully isolated at the end of the procedure as compared to 3.1 ± 1.3 in the single-ring (box) group (p=0.38). All patients in the box group required additional posterior lesions in order to achieve electrical isolation of the PVs. Single-ring ablation was associated with longer procedure duration (p=0.01) and ablation time (p=0.001). After a single procedure, the proportion of patients free of any atrial tachycardia (AT)/atrial fibrillation (AF) episode at 12-month follow-up was 57 % in the box group and 58 % in the circ group. Using RMN, only minor complications have been observed. RMN-guided single-ring PVA provides comparable acute and long-term success rates as compared to RMN-guided circumferential PVA but requires additional posterior lesions to achieve PV isolation and increased procedure and ablation time. Procedural complication rates are low when using RMN.

  20. [Predictive value of HATCH score on atrial fibrillation recurrence post radiofrequency catheter ablation].

    PubMed

    Miao, Dan-dan; Zang, Xiao-biao; Zhang, Shu-long; Gao, Lian-jun; Xia, Yun-long; Yin, Xiao-meng; Chang, Dong; Dong, Ying-xue; Yang, Yan-zong

    2012-10-01

    To determine the predictive value of HATCH score on recurrence of atrial fibrillation (AF) after radiofrequency catheter ablation (RFCA). The data of 123 consecutive AF patients (74 paroxysmal and 49 persistent AF) who underwent RFCA between April 2009 and December 2010 in our department were retrospectively analyzed. Of theses patients, 65 (52.9%) patients had HATCH score = 0, 41 (33.3%) patients had HATCH score = 1, and 17 (13.8%) patients had HATCH score ≥ 2 (HATCH = 2 in 11 patients, HATCH = 3 in 5 patients, HATCH = 4 in 1 patient). The recurrence was defined as atrial tachyarrhythmia lasting more than 30 seconds after 3 months post RFCA. The patients were divided into recurrence group and no recurrence group. Relationship between HATCH score and recurrence was observed. There were 43 cases in recurrence group and 80 cases in no recurrence group. After 12 months follow-up, HATCH score was significant higher in recurrence group than in non-recurrence group [(0.91 ± 0.94) score vs. (0.53 ± 0.80) score, P < 0.05]. The ratio of patients with HATCH ≥ 2 in recurrence group was higher than in non-recurrence group [23.3% (10/43) vs. 8.8% (7/80), P < 0.01]. The sensitivity and specificity of HATCH ≥ 2 to define the risk of recurrence was 25.0%, 92.4% respectively. Cumulative non-recurrence rate of patients with HATCH score ≥ 2 was lower than patients with HATCH score = 0 and 1 (P < 0.05). Higher HATCH score is associated with increased risk of AF recurrence post RFCA.

  1. Limitations of dormant conduction as a predictor of atrial fibrillation recurrence and pulmonary vein reconnection after catheter ablation.

    PubMed

    Lin, Frank S; Ip, James E; Markowitz, Steven M; Liu, Christopher F; Thomas, George; Lerman, Bruce B; Cheung, Jim W

    2015-05-01

    Adenosine (ADO) can uncover dormant conduction following pulmonary vein (PV) isolation. We sought to identify the value of dormant conduction for predicting atrial fibrillation (AF) recurrence and chronic PV reconnection. One hundred fifty-two patients (80 male; age 60 ± 11 years) undergoing PV isolation for AF were studied. After PV isolation, sites of ADO-induced PV reconnection were recorded and targeted with additional ablation. In patients undergoing repeat ablation for recurrent AF, chronic PV reconnection was assessed. Forty-five (30%) patients had ADO-induced PV reconnection following PV isolation. Dormant conduction was successfully eliminated with additional ablation in 41 (91%) of these patients. After follow-up of 598 ± 270 days, 60 (39%) patients had recurrent AF. Dormant PV conduction was not a significant predictor of AF recurrence (hazard ratio 1.51; 95% confidence interval: 0.89-2.56; P = 0.12) although three of four (75%) patients with residual dormant conduction following initial ablation developed recurrent AF. Twenty-six patients with recurrent AF underwent repeat ablation with 52 of 99 (53%) PVs found to have chronic reconnection. Nine of 11 (82%) PVs with dormant conduction and 43 of 88 (49%) PVs without dormant conduction at initial procedure had chronic reconnection at repeat ablation. When additional ablation is performed to eliminate ADO-induced PV reconnection after PV isolation, dormant conduction is not a significant predictor of recurrent AF. Although PVs with dormant conduction at initial procedure may develop chronic reconnection, the majority of PVs that show conduction recovery at repeat ablation occur in nondormant PVs. © 2015 Wiley Periodicals, Inc.

  2. Asymptomatic Ventricular Pre-excitation: Between Sudden Cardiac Death and Catheter Ablation.

    PubMed

    Brugada, Josep; Keegan, Roberto

    2018-03-01

    Debate about the best clinical approach to the management of asymptomatic patients with ventricular pre-excitation and advice on whether or not to invasively stratify and ablate is on-going. Weak evidence about the real risk of sudden cardiac death and the potential benefit of catheter ablation has probably prevented the clarification of action in this not infrequent and sometimes conflicting clinical situation. After analysing all available data, real evidence-based medicine could be the alternative strategy for managing this group of patients. According to recent surveys, most electrophysiologists invasively stratify. Based on all accepted risk factors - younger age, male, associated structural heart disease, posteroseptal localisation, ability of the accessory pathway to conduct anterogradely at short intervals of ≤250 milliseconds and inducibility of sustained atrioventricular re-entrant tachycardia and/or atrial fibrillation - a shared decisionmaking process on catheter ablation is proposed.

  3. Recurring patterns of atrial fibrillation in surface ECG predict restoration of sinus rhythm by catheter ablation.

    PubMed

    Di Marco, Luigi Yuri; Raine, Daniel; Bourke, John P; Langley, Philip

    2014-11-01

    Non-invasive tools to help identify patients likely to benefit from catheter ablation (CA) of atrial fibrillation (AF) would facilitate personalised treatment planning. To investigate atrial waveform organisation through recurrence plot indices (RPI) and their ability to predict CA outcome. One minute 12-lead ECG was recorded before CA from 62 patients with AF (32 paroxysmal AF; 45 men; age 57±10 years). Organisation of atrial waveforms from i) TQ intervals in V1 and ii) QRST suppressed continuous AF waveforms (CAFW), were quantified using RPI: percentage recurrence (PR), percentage determinism (PD), entropy of recurrence (ER). Ability to predict acute (terminating vs. non-terminating AF), 3-month and 6-month postoperative outcome (AF vs. AF free) were assessed. RPI either by TQ or CAFW analysis did not change significantly with acute outcome. Patients arrhythmia-free at 6-month follow-up had higher organisation in TQ intervals by PD (p<0.05) and ER (p<0.005) and both were significant predictors of 6-month outcome (PD (AUC=0.67, p<0.05) and ER (AUC=0.72, p<0.005)). For paroxysmal AF cases, all RPI predicted 3-month (AUC(ER)=0.78, p<0.05; AUC(PD)=0.79, p<0.05; AUC(PR)=0.80, p<0.01) and 6-month (AUC(ER)=0.81, p<0.005; AUC(PD)=0.75, p<0.05; AUC(PR)=0.71, p<0.05) outcome. CAFW-derived RPIs did not predict acute or postoperative outcomes. Higher values of any RPI from TQ (values greater than 25th percentile of preoperative distribution) were associated with decreased risk of AF relapse at follow-up (hazard ratio ≤0.52, all p<0.05). Recurring patterns from preprocedural 1-minute recordings of ECG TQ intervals were significant predictors of CA 6-month outcome. Copyright © 2014 Elsevier Ltd. All rights reserved.

  4. History of hyperthyroidism and long-term outcome of catheter ablation of drug-refractory atrial fibrillation.

    PubMed

    Wongcharoen, Wanwarang; Lin, Yenn-Jiang; Chang, Shih-Lin; Lo, Li-Wei; Hu, Yu-Feng; Chung, Fa-Po; Chong, Eric; Chao, Tze-Fan; Tuan, Ta-Chuan; Chang, Yao-Ting; Lin, Chin-Yu; Liao, Jo-Nan; Lin, Yi-Chun; Chen, Yun-Yu; Chen, Shih-Ann

    2015-09-01

    Hyperthyroidism is a known reversible cause of atrial fibrillation (AF). However, some patients remain in AF despite restoration of euthyroid status. The purpose of this study was to compare the electrophysiologic characteristics and long-term ablation outcome in AF patients with and without history of hyperthyroidism. The study enrolled 717 consecutive patients with AF who underwent first AF ablation, which involved pulmonary vein (PV) isolation in paroxysmal AF and additional substrate modification in nonparoxysmal AF patients. Eighty-four patients (12%) with hyperthyroidism history were compared to those without. Euthyroid status was achieved for ≥3 months before ablation in hyperthyroid patients. Patients with hyperthyroid history were associated with older age, more female gender, lower mean right atrial voltage, higher number of PV ectopic foci (1.3 ± 0.4 vs 1.0 ± 0.2, P < .01), and higher prevalence of non-PV foci (42% vs 23%, P < .01). Ectopic foci from ligament of Marshall were demonstrated more often in hyperthyroid patients (7.1% vs 1.6%, P < .01) in whom alcohol ablations were required. After propensity score matching for potential covariates, history of hyperthyroidism was an independent predictor of AF recurrence after single procedure (hazard ratio 2.07, 95% confidence interval 1.27-3.38). AF recurrence rates after multiple procedures were not different between patients with and those without hyperthyroid history. Patients with hyperthyroid history had a significantly higher number of PV ectopies and higher prevalence of non-PV ectopic foci compared to euthyroid patients, which resulted in a higher AF recurrence rate after a single procedure. Copyright © 2015 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  5. Apixaban versus Warfarin for the Prevention of Periprocedural Cerebral Thromboembolism in Atrial Fibrillation Ablation: Multicenter Prospective Randomized Study.

    PubMed

    Kuwahara, Taishi; Abe, Mitsunori; Yamaki, Masaru; Fujieda, Hiroyuki; Abe, Yumiko; Hashimoto, Katsushi; Ishiba, Misako; Sakai, Hirotsuka; Hishikari, Keiichi; Takigawa, Masateru; Okubo, Kenji; Takagi, Katsumasa; Tanaka, Yasuaki; Nakajima, Jun; Takahashi, Atsushi

    2016-05-01

    Stroke can be a life-threatening complication of atrial fibrillation (AF) catheter ablation. Uninterrupted warfarin treatment contributes to minimizing the risk of stroke complications. This was a prospective, open-label, randomized, multicenter study assessing the safety and efficacy of apixaban for the prevention of cerebral thromboembolism complicating AF catheter ablation. Two hundred patients with drug-resistant AF were equally assigned to take either apixaban (5 mg or 2.5 mg twice daily) or warfarin (target international normalized ratio, 2-3) for at least 1 month before AF ablation. Neither drug regimen was interrupted throughout the operative period. Diffusion-weighted magnetic resonance imaging was performed for all patients to detect silent cerebral infarction (SCI) after the ablation. Primary outcomes were defined as the occurrence of stroke, transient ischemic attack, SCI, or major bleeding that required intervention. The secondary outcome was minor bleeding. The groups did not statistically differ in patients' backgrounds or procedural parameters. During AF ablation, the apixaban group required administration of more heparin to maintain an activated clotting time > 300 seconds than the warfarin group (apixaban, 14,000 ± 4,000 units; warfarin, 9,000 ± 3,000 units). Three primary outcome events occurred in each group (apixaban, 2 SCI and 1 major bleed; warfarin, 3 SCI, P = 1.00), and 3 and 4 secondary outcome events occurred in the apixaban and warfarin groups (P = 0.70), respectively. Apixaban has similar safety and effectiveness to warfarin for the prevention of cerebral thromboembolism during the periprocedural period of AF ablation. © 2016 Wiley Periodicals, Inc.

  6. Asymptomatic Ventricular Pre-excitation: Between Sudden Cardiac Death and Catheter Ablation

    PubMed Central

    Brugada, Josep

    2018-01-01

    Debate about the best clinical approach to the management of asymptomatic patients with ventricular pre-excitation and advice on whether or not to invasively stratify and ablate is on-going. Weak evidence about the real risk of sudden cardiac death and the potential benefit of catheter ablation has probably prevented the clarification of action in this not infrequent and sometimes conflicting clinical situation. After analysing all available data, real evidence-based medicine could be the alternative strategy for managing this group of patients. According to recent surveys, most electrophysiologists invasively stratify. Based on all accepted risk factors – younger age, male, associated structural heart disease, posteroseptal localisation, ability of the accessory pathway to conduct anterogradely at short intervals of ≤250 milliseconds and inducibility of sustained atrioventricular re-entrant tachycardia and/or atrial fibrillation – a shared decisionmaking process on catheter ablation is proposed. PMID:29636970

  7. Rationale and design of the NO-PARTY trial: near-zero fluoroscopic exposure during catheter ablation of supraventricular arrhythmias in young patients.

    PubMed

    Casella, Michela; Dello Russo, Antonio; Pelargonio, Gemma; Bongiorni, Maria Grazia; Del Greco, Maurizio; Piacenti, Marcello; Andreassi, Maria Grazia; Santangeli, Pasquale; Bartoletti, Stefano; Moltrasio, Massimo; Fassini, Gaetano; Marini, Massimiliano; Di Cori, Andrea; Di Biase, Luigi; Fiorentini, Cesare; Zecchi, Paolo; Natale, Andrea; Picano, Eugenio; Tondo, Claudio

    2012-10-01

    Radiofrequency catheter ablation is the mainstay of therapy for supraventricular tachyarrhythmias. Conventional radiofrequency catheter ablation requires the use of fluoroscopy, thus exposing patients to ionising radiation. The feasibility and safety of non-fluoroscopic radiofrequency catheter ablation has been recently reported in a wide range of supraventricular tachyarrhythmias using the EnSite NavX™ mapping system. The NO-PARTY is a multi-centre, randomised controlled trial designed to test the hypothesis that catheter ablation of supraventricular tachyarrhythmias guided by the EnSite NavX™ mapping system results in a clinically significant reduction in exposure to ionising radiation compared with conventional catheter ablation. The study will randomise 210 patients undergoing catheter ablation of supraventricular tachyarrhythmias to either a conventional ablation technique or one guided by the EnSite NavX™ mapping system. The primary end-point is the reduction of the radiation dose to the patient. Secondary end-points include procedural success, reduction of the radiation dose to the operator, and a cost-effectiveness analysis. In a subgroup of patients, we will also evaluate the radiobiological effectiveness of dose reduction by assessing acute chromosomal DNA damage in peripheral blood lymphocytes. NO-PARTY will determine whether radiofrequency catheter ablation of supraventricular tachyarrhythmias guided by the EnSite NavX™ mapping system is a suitable and cost-effective approach to achieve a clinically significant reduction in ionising radiation exposure for both patient and operator.

  8. Comparison of resource utilization of pulmonary vein isolation: cryoablation versus RF ablation with three-dimensional mapping in the Value PVI Study.

    PubMed

    DeVille, J Brian; Svinarich, J Thomas; Dan, Dan; Wickliffe, Andrew; Kantipudi, Charan; Lim, Hae W; Plummer, Lisa; Baker, James; Kowalski, Marcin; Baydoun, Hassan; Jenkins, Mark; Chang-Sing, Peter

    2014-06-01

    Point-to-point focal radiofrequency (RF) catheter ablation for aberrant pulmonary vein triggers that manifest into atrial fibrillation (AF) is the traditional method for treating symptomatic drug-resistant paroxysmal AF (PAF) when an ablation procedure is warranted. More recently, pulmonary vein isolation (PVI) using the cryoballoon has been demonstrated to be safe and effective (STOP AF clinical trial). Currently, two small studies have reviewed the procedural efficiency when comparing cryoballoon to focal RF catheter ablation procedures; however, no multicenter study has yet reported on this comparison of the two types of ablation catheters. A multicenter retrospective chart extraction and evaluation was conducted at seven geographically mixed cardiac care centers. The study examined procedural variables during ablation for PVI in PAF patients. In several procedural measurements, the two modalities were comparable in efficiencies, including: acute PVI >96%; length of hospital stay at approximately 27 hours; and about 30% usage of adenosine after procedural testing. However, when compared to RF catheters, the cryoballoon procedure demonstrated a 13% reduction in laboratory occupancy time (247 min vs 283 min), a 13% reduction in procedure time (174 min vs 200 min), and a 21% reduction in fluoroscopy time (33 min vs 42 min). Additionally, when comparing the material usage of both cryoballoon and RF catheters, the cryoballoon used more radiopaque contrast agent (78 cc vs 29 cc) while using less intraprocedural saline (1234 cc vs 2386 cc), intracardiac echocardiography (88% vs 99%), three-dimensional electroanatomic mapping (30% vs 87%), and fewer transseptal punctures (1.5 vs 1.9). This study is the first United States multicenter examination to report the procedural comparisons between the cryoballoon and focal RF catheters when used for the treatment of PAF patients. In this hospital chart review study, potential advantages were found when operating the cryoballoon

  9. Importance of catheter contact force during irrigated radiofrequency ablation: evaluation in a porcine ex vivo model using a force-sensing catheter.

    PubMed

    Thiagalingam, Aravinda; D'Avila, Andre; Foley, Lori; Guerrero, J Luis; Lambert, Hendrik; Leo, Giovanni; Ruskin, Jeremy N; Reddy, Vivek Y

    2010-07-01

    Ablation electrode-tissue contact has been shown to be an important determinant of lesion size and safety during nonirrigated ablation but little data are available during irrigated ablation. We aimed to determine the importance of contact force during irrigated-tip ablation. Freshly excised hearts from 11 male pigs were perfused and superfused using fresh, heparinized, oxygenated swine blood in an ex vivo model. One-minute ablations were placed using one of 3 different power control strategies (impedance control-15 Omega target impedance drop, and 20 W or 30 W fixed power) and 3 different contact forces (2 g, 20 g, and 60 g) to give a grid of 9 ablation groups. The force sensing catheter (Tacticath, Endosense SA) was irrigated at 17 mL/min for all of the ablations. Of a total 101 ablations, no thrombus formation was noted but popping was seen in 17 lesions. The lesion depth and incidence of pops was 5.0 +/- 1.3 mm /0%, 5.0 +/- 1.6 mm /10% and 6.7 +/- 2.5 mm /45% for the 15 Omega, 20 W, and 30 W groups (P < 0.01), respectively, and 4.4 +/- 1.8 mm /3%, 5.8 +/- 1.6 mm /17% and 6.6 +/- 2.0 mm /37% for the 2 g, 20 g, and 60 g groups, respectively (P < 0.01). The impedance drop in the first 5 seconds was significantly correlated to catheter contact force: 9.7 +/- 9.9 Omega, 22.3 +/- 11.0 Omega, and 41.7 +/- 22.1 Omega, respectively, for the 2 g, 20 g, and 60 g groups (Pearson's r = 0.65, P < 0.01). Catheter contact force has an important impact on both ablation lesion size and the incidence of pops.

  10. Prediction of radiofrequency ablation lesion formation using a novel temperature sensing technology incorporated in a force sensing catheter.

    PubMed

    Rozen, Guy; Ptaszek, Leon; Zilberman, Israel; Cordaro, Kevin; Heist, E Kevin; Beeckler, Christopher; Altmann, Andres; Ying, Zhang; Liu, Zhenjiang; Ruskin, Jeremy N; Govari, Assaf; Mansour, Moussa

    2017-02-01

    Real-time radiofrequency (RF) ablation lesion assessment is a major unmet need in cardiac electrophysiology. The purpose of this study was to assess whether improved temperature measurement using a novel thermocoupling (TC) technology combined with information derived from impedance change, contact force (CF) sensing, and catheter orientation allows accurate real-time prediction of ablation lesion formation. RF ablation lesions were delivered in the ventricles of 15 swine using a novel externally irrigated-tip catheter containing 6 miniature TC sensors in addition to force sensing technology. Ablation duration, power, irrigation rate, impedance drop, CF, and temperature from each sensor were recorded. The catheter "orientation factor" was calculated using measurements from the different TC sensors. Information derived from all the sources was included in a mathematical model developed to predict lesion depth and validated against histologic measurements. A total of 143 ablation lesions were delivered to the left ventricle (n = 74) and right ventricle (n = 69). Mean CF applied during the ablations was 14.34 ± 3.55g, and mean impedance drop achieved during the ablations was 17.5 ± 6.41 Ω. Mean difference between predicted and measured ablation lesion depth was 0.72 ± 0.56 mm. In the majority of lesions (91.6%), the difference between estimated and measured depth was ≤1.5 mm. Accurate real-time prediction of RF lesion depth is feasible using a novel ablation catheter-based system in conjunction with a mathematical prediction model, combining elaborate temperature measurements with information derived from catheter orientation, CF sensing, impedance change, and additional ablation parameters. Copyright © 2016 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  11. Remote magnetic navigation for accurate, real-time catheter positioning and ablation in cardiac electrophysiology procedures.

    PubMed

    Filgueiras-Rama, David; Estrada, Alejandro; Shachar, Josh; Castrejón, Sergio; Doiny, David; Ortega, Marta; Gang, Eli; Merino, José L

    2013-04-21

    New remote navigation systems have been developed to improve current limitations of conventional manually guided catheter ablation in complex cardiac substrates such as left atrial flutter. This protocol describes all the clinical and invasive interventional steps performed during a human electrophysiological study and ablation to assess the accuracy, safety and real-time navigation of the Catheter Guidance, Control and Imaging (CGCI) system. Patients who underwent ablation of a right or left atrium flutter substrate were included. Specifically, data from three left atrial flutter and two counterclockwise right atrial flutter procedures are shown in this report. One representative left atrial flutter procedure is shown in the movie. This system is based on eight coil-core electromagnets, which generate a dynamic magnetic field focused on the heart. Remote navigation by rapid changes (msec) in the magnetic field magnitude and a very flexible magnetized catheter allow real-time closed-loop integration and accurate, stable positioning and ablation of the arrhythmogenic substrate.

  12. Remote Magnetic Navigation for Accurate, Real-time Catheter Positioning and Ablation in Cardiac Electrophysiology Procedures

    PubMed Central

    Filgueiras-Rama, David; Estrada, Alejandro; Shachar, Josh; Castrejón, Sergio; Doiny, David; Ortega, Marta; Gang, Eli; Merino, José L.

    2013-01-01

    New remote navigation systems have been developed to improve current limitations of conventional manually guided catheter ablation in complex cardiac substrates such as left atrial flutter. This protocol describes all the clinical and invasive interventional steps performed during a human electrophysiological study and ablation to assess the accuracy, safety and real-time navigation of the Catheter Guidance, Control and Imaging (CGCI) system. Patients who underwent ablation of a right or left atrium flutter substrate were included. Specifically, data from three left atrial flutter and two counterclockwise right atrial flutter procedures are shown in this report. One representative left atrial flutter procedure is shown in the movie. This system is based on eight coil-core electromagnets, which generate a dynamic magnetic field focused on the heart. Remote navigation by rapid changes (msec) in the magnetic field magnitude and a very flexible magnetized catheter allow real-time closed-loop integration and accurate, stable positioning and ablation of the arrhythmogenic substrate. PMID:23628883

  13. Factors affecting basket catheter detection of real and phantom rotors in the atria: A computational study.

    PubMed

    Martinez-Mateu, Laura; Romero, Lucia; Ferrer-Albero, Ana; Sebastian, Rafael; Rodríguez Matas, José F; Jalife, José; Berenfeld, Omer; Saiz, Javier

    2018-03-01

    Anatomically based procedures to ablate atrial fibrillation (AF) are often successful in terminating paroxysmal AF. However, the ability to terminate persistent AF remains disappointing. New mechanistic approaches use multiple-electrode basket catheter mapping to localize and target AF drivers in the form of rotors but significant concerns remain about their accuracy. We aimed to evaluate how electrode-endocardium distance, far-field sources and inter-electrode distance affect the accuracy of localizing rotors. Sustained rotor activation of the atria was simulated numerically and mapped using a virtual basket catheter with varying electrode densities placed at different positions within the atrial cavity. Unipolar electrograms were calculated on the entire endocardial surface and at each of the electrodes. Rotors were tracked on the interpolated basket phase maps and compared with the respective atrial voltage and endocardial phase maps, which served as references. Rotor detection by the basket maps varied between 35-94% of the simulation time, depending on the basket's position and the electrode-to-endocardial wall distance. However, two different types of phantom rotors appeared also on the basket maps. The first type was due to the far-field sources and the second type was due to interpolation between the electrodes; increasing electrode density decreased the incidence of the second but not the first type of phantom rotors. In the simulations study, basket catheter-based phase mapping detected rotors even when the basket was not in full contact with the endocardial wall, but always generated a number of phantom rotors in the presence of only a single real rotor, which would be the desired ablation target. Phantom rotors may mislead and contribute to failure in AF ablation procedures.

  14. Percutenous Catheter Ablation of the Accessory Pathway in a Patient with Wolff-Parkinson-White Syndrome Associated with Familial Atrial Fibrillation

    PubMed Central

    Cay, Serkan; Topaloglu, Serkan; Aras, Dursun

    2008-01-01

    Percutenous catheter ablation of the accessory pathway in Wolff-Parkinson-White syndrome is a highly successful mode of therapy. Sudden cardiac arrest survivors associated with WPW syndrome should undergo radiofrequency catheter ablation. WPW syndrome associated with familial atrial fibrillation is a very rare condition. Herein, we describe a case who presented with sudden cardiac arrest secondary to WPW syndrome and familial atrial fibrillation and treated via radiofrequency catheter ablation. PMID:18379660

  15. Contact force with magnetic-guided catheter ablation.

    PubMed

    Bessière, Francis; Zikry, Christopher; Rivard, Lena; Dyrda, Katia; Khairy, Paul

    2018-05-01

    Achieving adequate catheter tip-tissue contact is essential for delivering robust radiofrequency (RF) ablation lesions. We measured the contact force generated by a remote magnetic-guided catheter navigation system. A plexiglass model with an integrated scale was fashioned to mimic transvenous and retrograde access to sites in the right atrium and right and left ventricles. An 8 Fr RF ablation catheter was steered by remote magnetic guidance at fields of 0.08 and 0.10 T, with and without a long sheath positioned at the entrance of the chamber. Ten contact force readings were taken at each setting, with the scale recalibrated prior to each measurement. Generalized estimating equations were used to compare contact force measurements while adjusting for the non-independent data structure. A total of 240 contact force measurements were taken. Without a long sheath, contact forces with magnetic fields of 0.10 T (n = 60) and 0.08 T (n = 60) were similar (6.1 ± 1.4 g vs. 6.0 ± 1.3 g, P = 0.089). Contact forces were not significantly different with simulated transvenous (n = 80) and retrograde aortic (n = 40) approaches (6.2 ± 1.4 g vs. 5.7 ± 1.2 g, P = 0.132). The contact force increased substantially with a long sheath (P < 0.001) and was significantly higher with 0.10 T (n = 60) vs. 0.08 T (n = 60) fields (20.4 ± 0.6 g vs. 18.0 ± 0.5 g, P < 0.001). Magnetic fields of 0.08 and 0.10 T provide stable catheter contact forces, as reflected by the small variability between measurements. The average contact force is approximately 6 g without a sheath and increases to 20 g with a long sheath positioned at the entrance of the chamber of interest.

  16. Meta-analysis of efficacy and safety of apixaban and uninterrupted apixaban therapy compared to vitamin K antagonists in patients undergoing catheter ablation for atrial fibrillation.

    PubMed

    Ukaigwe, Anene; Shrestha, Pragya; Karmacharya, Paras; Hussain, Sarah K; Samii, Soraya; Gonzalez, Mario D; Wolbrette, Deborah; Naccarrelli, Gerald V

    2017-03-01

    Apixaban is a Factor Xa inhibitor increasingly being used for stroke prevention in atrial fibrillation (AF). Although several studies have been done, the efficacy and safety of apixaban during the peri-procedural period of AF ablation remains unclear. We sought to systematically review pooled data from these various studies to evaluate thromboembolic and bleeding risks in patients undergoing catheter ablation for AF who are treated with apixaban (interrupted and uninterrupted). Studies comparing anticoagulation with apixaban or vitamin K antagonists (VKA) in patients undergoing ablation for AF were identified via an electronic search of MEDLINE, EMBASE, clinical trials.gov, and Cochrane Library from inception to January 2016. Study-specific risk ratios were calculated and combined with a fixed-effects model meta-analysis. In the analysis of 2100 pooled patients, thromboembolic complications (TE) occurred in 14/778 (1.80 %) patients in the apixaban group (AG) compared to 20/1322 patients in the VKA group (RR 1.03, 95 % CI 0.55-1.90, p = 0.93, I 2  = 0 %). Major bleeding occurred in 9/778 (1.2 %) of the AG compared to 20/1322 (1.51 %) in the VKA group (RR 1.03, 95 % CI 0.55-1.90, p = 0.93, I 2  = 0 %). In uninterrupted apixaban group (uAG), TE occurred in 4/585 (0.68 %) patients in the uAG compared to 6/910 (0.66 %) in VKA group (RR 0.86, 95 % CI 0.25-2.95, p = 0.81, I 2  = 0 %). Major bleeding occurred in 5/585 (0.85 %) in uAG compared to 7/910 (0.77 %) in the VKA group (RR 1.20, 95 % CI 0.37-3.88, p = 0.76, I 2  = 0 %). Our study demonstrates patients treated with apixaban and VKA during the peri-procedural period for AF ablation have similar rates of TE and bleeding complications. Interrupted and uninterrupted apixaban strategies were associated with similar outcomes.

  17. Mechanistic Comparison of "Nearly Missed" Versus "On-Target" Rotor Ablation.

    PubMed

    Yamazaki, Masatoshi; Avula, Uma Mahesh R; Berenfeld, Omer; Kalifa, Jérôme

    2015-08-01

    This study used advanced optical mapping techniques to examine atrial fibrillation (AF) dynamics before and after 2 distinct electrogram-based ablation strategies: complex fractionated atrial electrograms (CFAEs) and DFmax/rotor ablation. Among the electrogram analytical features proposed to unravel the atrial regions that perpetuate AF, CFAEs, highest dominant frequency sites (DFmax), and, more recently, phase analysis-enabled rotor mapping have received the largest attention. Still, the mechanisms by which these approaches modulate AF dynamics and lead to AF termination are unknown. In Langendorff-perfused sheep hearts, AF was maintained by the continuous perfusion of acetylcholine and high-resolution endocardial-epicardial optical videos were recorded from the left atrial free wall and the posterior left atrium. Then, DFmax/rotor regions (n = 7), or CFAE regions harboring the highest wavebreak density (HWD) (n = 5), were targeted with a 4F ablation catheter (5 to 15 W, 30 to 60 s/point). Thereafter, we examined the changes in AF dynamics and whether AF terminated. DFmax/rotor point ablation resulted in a significant decrease in DFmax values. In 2 animals AF terminated, whereas in the remaining 5 animals the post-ablation DFmax domain remained in the vicinity of its pre-ablation location. However, after HWD/CFAEs density ablation, DFmax values did not change, AF did not terminate, and post-ablation DFmax domains relocated from the left atrial free wall to the pulmonary vein-posterior left atrium region. In another group of hearts (n = 12), we observed that upon a progressive increase in acetylcholine concentration-mimicking the acute electrophysiological changes occurring after ablation-3-dimensional rotors drifted from one atrial region to another along large gradients of myocardial thickness. "On-target" DFmax/rotor ablation leads to the annihilation of the fibrillation-driving rotor. This translates into large decreases in AF frequency or AF termination. In

  18. Radiofrequency Catheter Ablation Improves the Quality of Life Measured with a Short Form-36 Questionnaire in Atrial Fibrillation Patients: A Systematic Review and Meta-Analysis

    PubMed Central

    Choi, Jong-Il; Kim, Young-Hoon

    2016-01-01

    Background The main purpose of performing radiofrequency catheter ablation (RFCA) in atrial fibrillation (AF) patients is to improve the quality of life (QoL) and alleviate AF-related symptoms. We aimed to determine the qualitative and quantitative effects of RFCA on the QoL in AF patients. Methods We performed a systemic review and meta-analysis using a random effects model. We searched for the studies that reported the physical component summary score (PCS) and mental component summary score (MCS) of the short form-36, a validated system to assess and quantify the QoL, before and after RFCA in AF patients. PCS and MCS are T-scores with a mean of 50 and standard deviation of 10. Results Of the 470 studies identified through systematic search, we included 13 studies for pre-RFCA vs. the post-RFCA analysis and 5 studies for treatment success vs. AF recurrence analyses. In the pre-RFCA vs. post-RFCA analysis, RFCA was associated with a significant increase in both the PCS (weighted mean difference [WMD] = 6.33 [4.81–7.84]; p < 0.001) and MCS (WMD = 7.80 [6.15–9.44]; p < 0.001). The ΔPCS (post-RFCA PCS–pre-RFCA PCS) and ΔMCS values were used for the treatment success vs. AF recurrence analysis. Patients with successful ablation had a higher ΔPCS (WMD = 7.46 [4.44–10.49]; p < 0.001) and ΔMCS (WMD = 7.59 [4.94–10.24]; p < 0.001). Conclusions RFCA is associated with a significant increase in the PCS and MCS in AF patients. Patients without AF recurrence after RFCA had a better improvement in the PCS and MCS than patients who had AF recurrence. PMID:27681507

  19. Ablation as targeted perturbation to rewire communication network of persistent atrial fibrillation

    PubMed Central

    Tao, Susumu; Way, Samuel F.; Garland, Joshua; Chrispin, Jonathan; Ciuffo, Luisa A.; Balouch, Muhammad A.; Nazarian, Saman; Spragg, David D.; Marine, Joseph E.; Berger, Ronald D.; Calkins, Hugh

    2017-01-01

    Persistent atrial fibrillation (AF) can be viewed as disintegrated patterns of information transmission by action potential across the communication network consisting of nodes linked by functional connectivity. To test the hypothesis that ablation of persistent AF is associated with improvement in both local and global connectivity within the communication networks, we analyzed multi-electrode basket catheter electrograms of 22 consecutive patients (63.5 ± 9.7 years, 78% male) during persistent AF before and after the focal impulse and rotor modulation-guided ablation. Eight patients (36%) developed recurrence within 6 months after ablation. We defined communication networks of AF by nodes (cardiac tissue adjacent to each electrode) and edges (mutual information between pairs of nodes). To evaluate patient-specific parameters of communication, thresholds of mutual information were applied to preserve 10% to 30% of the strongest edges. There was no significant difference in network parameters between both atria at baseline. Ablation effectively rewired the communication network of persistent AF to improve the overall connectivity. In addition, successful ablation improved local connectivity by increasing the average clustering coefficient, and also improved global connectivity by decreasing the characteristic path length. As a result, successful ablation improved the efficiency and robustness of the communication network by increasing the small-world index. These changes were not observed in patients with AF recurrence. Furthermore, a significant increase in the small-world index after ablation was associated with synchronization of the rhythm by acute AF termination. In conclusion, successful ablation rewires communication networks during persistent AF, making it more robust, efficient, and easier to synchronize. Quantitative analysis of communication networks provides not only a mechanistic insight that AF may be sustained by spatially localized sources and

  20. Atrial Fibrillation Ablation Guided by a Novel Nonfluoroscopic Navigation System.

    PubMed

    Ballesteros, Gabriel; Ramos, Pablo; Neglia, Renzo; Menéndez, Diego; García-Bolao, Ignacio

    2017-09-01

    Rhythmia is a new nonfluoroscopic navigation system that is able to create high-density electroanatomic maps. The aim of this study was to describe the acute outcomes of atrial fibrillation (AF) ablation guided by this system, to analyze the volume provided by its electroanatomic map, and to describe its ability to locate pulmonary vein (PV) reconnection gaps in redo procedures. This observational study included 62 patients who underwent AF ablation with Rhythmia compared with a retrospective cohort who underwent AF ablation with a conventional nonfluoroscopic navigation system (Ensite Velocity). The number of surface electrograms per map was significantly higher in Rhythmia procedures (12 125 ± 2826 vs 133 ± 21 with Velocity; P < .001), with no significant differences in the total procedure time. The Orion catheter was placed for mapping in 99.5% of PV (95.61% in the control group with a conventional circular mapping catheter; P = .04). There were no significant differences in the percentage of PV isolation between the 2 groups. In redo procedures, an ablation gap could be identified on the activation map in 67% of the reconnected PV (40% in the control group; P = .042). The measured left atrial volume was lower than that calculated by computed tomography (109.3 v 15.2 and 129.9 ± 13.2 mL, respectively; P < .001). There were no significant differences in the number of complications. The Rhythmia system is effective for AF ablation procedures, with procedure times and safety profiles similar to conventional nonfluoroscopic navigation systems. In redo procedures, it appears to be more effective in identifying reconnected PV conduction gaps. Copyright © 2016 Sociedad Española de Cardiología. Published by Elsevier España, S.L.U. All rights reserved.

  1. Clinical Implications of Ablation of Drivers for Atrial Fibrillation: A Systematic Review and Meta-Analysis.

    PubMed

    Baykaner, Tina; Rogers, Albert J; Meckler, Gabriela L; Zaman, Junaid; Navara, Rachita; Rodrigo, Miguel; Alhusseini, Mahmood; Kowalewski, Christopher A B; Viswanathan, Mohan N; Narayan, Sanjiv M; Clopton, Paul; Wang, Paul J; Heidenreich, Paul A

    2018-05-01

    The outcomes from pulmonary vein isolation (PVI) for atrial fibrillation (AF) are suboptimal, but the benefits of additional lesion sets remain unproven. Recent studies propose ablation of AF drivers improves outcomes over PVI, yet with conflicting reports in the literature. We undertook a systematic literature review and meta-analysis to determine outcomes from ablation of AF drivers in addition to PVI or as a stand-alone procedure. Database search was done using the terms atrial fibrillation and ablation or catheter ablation and driver or rotor or focal impulse or FIRM (Focal Impulse and Rotor Modulation). We pooled data using random effects model and assessed heterogeneity with I 2 statistic. Seventeen studies met inclusion criteria, in a cohort size of 3294 patients. Adding AF driver ablation to PVI reported freedom from AF of 72.5% (confidence interval [CI], 62.1%-81.8%; P <0.01) and from all arrhythmias of 57.8% (CI, 47.5%-67.7%; P <0.01). AF driver ablation when added to PVI or as stand-alone procedure compared with controls produced an odds ratio of 3.1 (CI, 1.3-7.7; P =0.02) for freedom from AF and an odds ratio of 1.8 (CI, 1.2-2.7; P <0.01) for freedom from all arrhythmias in 4 controlled studies. AF termination rate was 40.5% (CI, 30.6%-50.9%) and predicted favorable outcome from ablation( P <0.05). In controlled studies, the addition of AF driver ablation to PVI supports the possible benefit of a combined approach of AF driver ablation and PVI in improving single-procedure freedom from all arrhythmias. However, most studies are uncontrolled and are limited by substantial heterogeneity in outcomes. Large multicenter randomized trials are needed to precisely define the benefits of adding driver ablation to PVI. © 2018 American Heart Association, Inc.

  2. Formation of thermal coagulum on multielectrode catheters during phased radiofrequency energy ablation of persistent atrial fibrillation.

    PubMed

    Debruyne, Philippe; Rossenbacker, Tom; Vankelecom, Bart; Charlier, Filip; Roosen, John; Ector, Bavo; Janssens, Luc

    2014-02-01

    Radiofrequency ablation (RFA) can unfavorably cause coagulum on the ablation electrode. The aim of this study was to assess this phenomenon on three different multielectrode catheters used to treat persistent atrial fibrillation with duty-cycled RFA. Twenty-six consecutive patients have been treated with the pulmonary vein ablation catheter (PVAC) and the multiarray ablation catheter (MAAC). In 13 patients, additional ablation with the multiarray septal catheter (MASC) has been performed. The multichannel RF generator GENius™ (Medtronic Inc., Minneapolis, MN, USA) independently delivered energy in a bipolar and unipolar mode (ratio of 4/1, 2/1, or 1/1) to any of the electrodes. Versions 14.2, 14.3, and 14.4 of the generator were used. Coagulum presence was determined postablation by careful visual inspection of the catheter electrodes. No coagulum formation was visualized on the PVACs. Coagulum formation was visualized in 59% of the electrodes of the MAACs using a 2/1 mode and the 14.2 software version versus 69% using the 14.4 version and a 2/1 mode (P = 0.7) versus 14% of the electrodes applying a 1/1 ratio and the 14.4 software version (P < 0.001). Duty-cycled RFA in 2/1 bipolar/unipolar ratio generates a substantial frequency of coagulum formation on the multielectrode catheters MAAC and MASC. The use of the 14.4 version of the software to drive the RF generator and the use of energy in the default 1/1 bipolar/unipolar ratio could significantly reduce the frequency of coagulum formation, but so far, could not completely overcome it. The PVAC did not form coagulum, regardless of generator version or energy ratio used. ©2013, The Authors. Journal compilation ©2013 Wiley Periodicals, Inc.

  3. Intracardiac echo-guided radiofrequency catheter ablation of atrial fibrillation in patients with atrial septal defect or patent foramen ovale repair: a feasibility, safety, and efficacy study.

    PubMed

    Lakkireddy, Dhanunjaya; Rangisetty, Umamahesh; Prasad, Subramanya; Verma, Atul; Biria, Mazda; Berenbom, Loren; Pimentel, Rhea; Emert, Martin; Rosamond, Thomas; Fahmy, Tamer; Patel, Dimpi; Di Biase, Luigi; Schweikert, Robert; Burkhardt, David; Natale, Andrea

    2008-11-01

    Intracardiac Echo-Guided Radiofrequency Catheter. Patients with atrial septal defect (ASD) are at higher risk for atrial fibrillation (AF) even after repair. Transseptal access in these patients is perceived to be difficult. We describe the feasibility, safety, and efficacy of pulmonary vein antral isolation (PVAI) in these patients. We prospectively compared post-ASD/patent foramen ovale (PFO) repair patients (group I, n = 45) with age-gender-AF type matched controls (group II, n = 45). All the patients underwent PVAI through a double transseptal puncture with a roving circular mapping catheter technique guided by intracardiac echocardiography (ICE). The short-term (3 months) and long-term (12 month) failure rates were assessed. In group I, 23 (51%) had percutaneous closure devices and 22 (49%) had a surgical closure. There was no significant difference between group I and II in the baseline characteristics. Intracardiac echo-guided double transseptal access was obtained in 98% of patients in group I and in 100% of patients in group II. PVAI was performed in all patients, with right atrial flutter ablation in 7 patients in group I and in 4 patients in group II. Over a mean follow-up of 15 +/- 4 months, group I had higher short-term (18% vs 13%, P = 0.77) and long-term recurrence (24% vs 18%, P = 0.6) than group II. There was no significant difference in the perioperative complications between the two groups. Echocardiography at 3 months showed interatrial communication in 2 patients in group I and 1 patient in group II, which resolved at 12 months. Percutaneous AF ablation using double transseptal access is feasible, safe, and efficacious in patients with ASD and PFO repairs.

  4. Prospective evaluation of a simplified approach for common atrial flutter radio frequency ablation with only two catheters.

    PubMed

    Klug, D; Lacroix, D; Marquié, C; Mairesse, G; Alix, D; Dennetière, S; d'Hautefeuille, B; Zghal, N; Kacet, S

    2001-07-01

    Intra-atrial conduction block within the inferior vena cava-tricuspid annulus isthmus (IVCT) has been shown to predict successful common atrial flutter ablation. However, its demonstration requires the use of several electrode catheters and mapping of the line of block. The aim of this study was prospectively to test the feasibility of a simplified ablation procedure using only two catheters. Radio frequency (RF) ablation of common atrial flutter was performed in 30 patients with the sole use of a catheter for atrial pacing and a RF catheter. RF ablation lesions were created in the IVCT. Surface ECG criteria were used to monitor the conduction within the IVCT. The end point during low lateral atrial pacing was an increment in the interval between the pacing artefact and the peak of the R wave in surface lead II >50 ms and clockwise rotation of the P wave axis beyond -30 degrees and inferiorly. Then, the line of lesions was mapped during atrial pacing with the RF catheter. Additional RF lesions were applied if mapping disclosed a zone of residual conduction. Otherwise the procedure was stopped if mapping showed parallel double potentials all along the line. Finally, the block was reassessed with a 'Halo' catheter. Surface ECG criteria were met in 26 patients. Mapping the line of lesions showed a complete corridor of parallel double potentials in these 26 cases and in 3 of the 4 patients in whom ECG criteria were not met. Conduction evaluated with the Halo catheter showed bi-directional complete block in these 29 patients. After a follow-up of 16 +/- 4 months there was no recurrence of atrial flutter. Surface ECG criteria combined with mapping of the line of block demonstrate evidence of bi-directional IVCT block. This simplified RF ablation of common atrial flutter is feasible with a low recurrence rate.

  5. Successful Radiofrequency Catheter Ablation for Wolff-Parkinson-White Syndrome Within the Neck of a Coronary Sinus Diverticulum

    PubMed Central

    Jang, Sung-Won; Kim, Dong-Bin; Kwon, Bum-Jun; Cho, Eun-Joo; Shin, Woo-Seung; Kim, Ji-Hoon; Jin, Seung-Won; Oh, Yong-Seog; Lee, Man-Young; Kim, Jae-Hyung

    2009-01-01

    Posteroseptal accessory pathways are often associated with coronary sinus diverticula. These diverticula contain myocardial coats which serve as a bypass tract. We report a 54-year-old woman who underwent radiofrequency (RF) catheter ablation for Wolff-Parkinson-White (WPW) syndrome. The surface electrocardiography (ECG) demonstrated pre-excitation, indicating a posteroseptal accessory pathway. A catheter ablation via a transaortic approach failed to ablate the accessory pathway. Coronary sinus venography revealed the presence of a diverticulum near the ostium. An electrogram in the neck of the diverticulum showed the coronary sinus myocardial extension potential, which was successfully ablated by delivery of RF energy. PMID:19949625

  6. Factors affecting basket catheter detection of real and phantom rotors in the atria: A computational study

    PubMed Central

    Romero, Lucia; Rodríguez Matas, José F.; Berenfeld, Omer; Saiz, Javier

    2018-01-01

    Anatomically based procedures to ablate atrial fibrillation (AF) are often successful in terminating paroxysmal AF. However, the ability to terminate persistent AF remains disappointing. New mechanistic approaches use multiple-electrode basket catheter mapping to localize and target AF drivers in the form of rotors but significant concerns remain about their accuracy. We aimed to evaluate how electrode-endocardium distance, far-field sources and inter-electrode distance affect the accuracy of localizing rotors. Sustained rotor activation of the atria was simulated numerically and mapped using a virtual basket catheter with varying electrode densities placed at different positions within the atrial cavity. Unipolar electrograms were calculated on the entire endocardial surface and at each of the electrodes. Rotors were tracked on the interpolated basket phase maps and compared with the respective atrial voltage and endocardial phase maps, which served as references. Rotor detection by the basket maps varied between 35–94% of the simulation time, depending on the basket’s position and the electrode-to-endocardial wall distance. However, two different types of phantom rotors appeared also on the basket maps. The first type was due to the far-field sources and the second type was due to interpolation between the electrodes; increasing electrode density decreased the incidence of the second but not the first type of phantom rotors. In the simulations study, basket catheter-based phase mapping detected rotors even when the basket was not in full contact with the endocardial wall, but always generated a number of phantom rotors in the presence of only a single real rotor, which would be the desired ablation target. Phantom rotors may mislead and contribute to failure in AF ablation procedures. PMID:29505583

  7. The role of adenosine challenge in catheter ablation for atrial fibrillation: A systematic review and meta-analysis.

    PubMed

    McLellan, Alex J A; Kumar, Saurabh; Smith, Catherine; Ling, Liang-Han; Prabhu, Sandeep; Kalman, Jonathan M; Kistler, Peter M

    2017-06-01

    Adenosine may unmask dormant PV conduction and facilitate consolidation of PV isolation. We performed a meta-analysis to determine the impact of adenosine administration on clinical outcomes in patients undergoing PVI. References and electronic databases reporting AF ablation and adenosine following PVI were searched through to 22nd November 2015. The impact of adenosine on freedom from AF was assessed in twenty publications after radiofrequency ablation (RFA), and in four publications after cryoablation to achieve PVI. Relative risks were calculated and combined in a meta-analysis using random effects modeling. In patients undergoing RFA with adenosine challenge, there was a significant reduction in freedom from AF in patients with versus without adenosine induced reconnection (RR 0.86; 95%CI 0.77-0.98; p=0.02) particularly if no further ablation was performed (RR 0.66; 95%CI 0.50-0.87; p<0.01). There was no difference when comparing outcomes in studies of routine adenosine challenge vs no adenosine (RR 1.07; 95%CI 0.93-1.22; p=0.36). There was a non-significant trend to an increase in freedom from AF in patients receiving routine adenosine challenge (RR 1.18 95%CI 0.99-1.42; p=0.07) in non-randomized studies using cryoablation. Adenosine induced PV reconnection following PVI is associated with a significant increase in AF recurrence, particularly if the reconnection sites are not targeted for ablation. The routine use of adenosine may be beneficial in AF ablation if given early post-PVI, at sufficient dose and reconnection is ablated. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. Approaches to catheter ablation for persistent atrial fibrillation.

    PubMed

    Verma, Atul; Jiang, Chen-yang; Betts, Timothy R; Chen, Jian; Deisenhofer, Isabel; Mantovan, Roberto; Macle, Laurent; Morillo, Carlos A; Haverkamp, Wilhelm; Weerasooriya, Rukshen; Albenque, Jean-Paul; Nardi, Stefano; Menardi, Endrj; Novak, Paul; Sanders, Prashanthan

    2015-05-07

    Catheter ablation is less successful for persistent atrial fibrillation than for paroxysmal atrial fibrillation. Guidelines suggest that adjuvant substrate modification in addition to pulmonary-vein isolation is required in persistent atrial fibrillation. We randomly assigned 589 patients with persistent atrial fibrillation in a 1:4:4 ratio to ablation with pulmonary-vein isolation alone (67 patients), pulmonary-vein isolation plus ablation of electrograms showing complex fractionated activity (263 patients), or pulmonary-vein isolation plus additional linear ablation across the left atrial roof and mitral valve isthmus (259 patients). The duration of follow-up was 18 months. The primary end point was freedom from any documented recurrence of atrial fibrillation lasting longer than 30 seconds after a single ablation procedure. Procedure time was significantly shorter for pulmonary-vein isolation alone than for the other two procedures (P<0.001). After 18 months, 59% of patients assigned to pulmonary-vein isolation alone were free from recurrent atrial fibrillation, as compared with 49% of patients assigned to pulmonary-vein isolation plus complex electrogram ablation and 46% of patients assigned to pulmonary-vein isolation plus linear ablation (P=0.15). There were also no significant differences among the three groups for the secondary end points, including freedom from atrial fibrillation after two ablation procedures and freedom from any atrial arrhythmia. Complications included tamponade (three patients), stroke or transient ischemic attack (three patients), and atrioesophageal fistula (one patient). Among patients with persistent atrial fibrillation, we found no reduction in the rate of recurrent atrial fibrillation when either linear ablation or ablation of complex fractionated electrograms was performed in addition to pulmonary-vein isolation. (Funded by St. Jude Medical; ClinicalTrials.gov number, NCT01203748.).

  9. Remote magnetic with open-irrigated catheter vs. manual navigation for ablation of atrial fibrillation: a systematic review and meta-analysis.

    PubMed

    Proietti, Riccardo; Pecoraro, Valentina; Di Biase, Luigi; Natale, Andrea; Santangeli, Pasquale; Viecca, Maurizio; Sagone, Antonio; Galli, Alessio; Moja, Lorenzo; Tagliabue, Ludovica

    2013-09-01

    The aim of this study was to determine the efficacy and safety of remote magnetic navigation (RMN) with open-irrigated catheter vs. manual catheter navigation (MCN) in performing atrial fibrillation (AF) ablation. We searched in PubMed (1948-2013) and EMBASE (1974-2013) studies comparing RMN with MCN. Outcomes considered were AF recurrence (primary outcome), pulmonary vein isolation (PVI), procedural complications, and data on procedure's performance. Odds ratios (OR) and mean difference (MD) were extracted and pooled using a random-effect model. Confidence in the estimates of the obtained effects (quality of evidence) was assessed using the Grading of Recommendations Assessment, Development and Evaluation approach. We identified seven controlled trials, six non-randomized and one randomized, including a total of 941 patients. Studies were at high risk of bias. No difference was observed between RMN and MCN on AF recurrence [OR 1.18, 95% confidence interval (CI) 0.85 to 1.65, P = 0.32] or PVI (OR 0.41, 95% CI 0.11-1.47, P = 0.17). Remote magnetic navigation was associated with less peri-procedural complications (Peto OR 0.41, 95% CI 0.19-0.88, P = 0.02). Mean fluoroscopy time was reduced in RMN group (-22.22 min; 95% CI -42.48 to -1.96, P = 0.03), although the overall duration of the procedure was longer (60.91 min; 95% CI 31.17 to 90.65, P < 0.0001). In conclusion, RMN is not superior to MCN in achieving freedom from recurrent AF at mid-term follow-up or PVI. The procedure implies less peri-procedural complications, requires a shorter fluoroscopy time but a longer total procedural time. For the low quality of the available evidence, a proper designed randomized controlled trial could turn the direction and the effect of the dimensions explored.

  10. Identification and Characterization of Sites Where Persistent Atrial Fibrillation Is Terminated by Localized Ablation.

    PubMed

    Zaman, Junaid A B; Sauer, William H; Alhusseini, Mahmood I; Baykaner, Tina; Borne, Ryan T; Kowalewski, Christopher A B; Busch, Sonia; Zei, Paul C; Park, Shirley; Viswanathan, Mohan N; Wang, Paul J; Brachmann, Johannes; Krummen, David E; Miller, John M; Rappel, Wouter Jan; Narayan, Sanjiv M; Peters, Nicholas S

    2018-01-01

    The mechanisms by which persistent atrial fibrillation (AF) terminates via localized ablation are not well understood. To address the hypothesis that sites where localized ablation terminates persistent AF have characteristics identifiable with activation mapping during AF, we systematically examined activation patterns acquired only in cases of unequivocal termination by ablation. We recruited 57 patients with persistent AF undergoing ablation, in whom localized ablation terminated AF to sinus rhythm or organized tachycardia. For each site, we performed an offline analysis of unprocessed unipolar electrograms collected during AF from multipolar basket catheters using the maximum -dV/dt assignment to construct isochronal activation maps for multiple cycles. Additional computational modeling and phase analysis were used to study mechanisms of map variability. At all sites of AF termination, localized repetitive activation patterns were observed. Partial rotational circuits were observed in 26 of 57 (46%) cases, focal patterns in 19 of 57 (33%), and complete rotational activity in 12 of 57 (21%) cases. In computer simulations, incomplete segments of partial rotations coincided with areas of slow conduction characterized by complex, multicomponent electrograms, and variations in assigning activation times at such sites substantially altered mapped mechanisms. Local activation mapping at sites of termination of persistent AF showed repetitive patterns of rotational or focal activity. In computer simulations, complete rotational activation sequence was observed but was sensitive to assignment of activation timing particularly in segments of slow conduction. The observed phenomena of repetitive localized activation and the mechanism by which local ablation terminates putative AF drivers require further investigation. © 2018 American Heart Association, Inc.

  11. Use of Oral Steroid and its Effects on Atrial Fibrillation Recurrence and Inflammatory Cytokines Post Ablation - The Steroid AF Study.

    PubMed

    Iskandar, Sandia; Reddy, Madhu; Afzal, Muhammad R; Rajasingh, Johnson; Atoui, Moustapha; Lavu, Madhav; Atkins, Donita; Bommana, Sudha; Umbarger, Linda; Jaeger, Misty; Pimentel, Rhea; Dendi, Raghuveer; Emert, Martin; Turagam, Mohit; Di Biase, Luigi; Natale, Andrea; Lakkireddy, Dhanunjaya

    2017-01-01

    Use of corticosteroids before and after atrial fibrillation (AF) ablation can decrease acute inflammation and reduce AF recurrence. To assess the efficacy of oral prednisone in improving the outcomes of pulmonary vein isolation with radiofrequency ablation and its effect on inflammatory cytokine. A total of 60 patients with paroxysmal AF undergoing radiofrequency ablation were randomized (1:1) to receive either 3 doses of 60 mg daily of oral prednisone or a placebo. Inflammatory cytokine levels (TNF-α, IL-1, IL6, IL-8) were measured at baseline, prior to ablation, immediately after ablation, and 24 hours post ablation. Patients underwent 30 day event monitoring at 3 months, 6 months and 12 months post procedure. Immediate post ablation levels of inflammatory cytokines were lower in the steroid group when compared to the placebo group; IL-6: 9.0 ±7 vs 15.8 ±13 p=0.031; IL-8: 10.5 ±9 vs 15.3 ±8; p=0.047 respectively. Acute PV reconnection rates during the procedure (7/23% vs 10/36%; p = 0.39), and RF ablation time (51±13 vs 56±11 min, p = 0.11) trended to be lower in the placebo group than the steroid group. There was no difference in the incidence of early recurrence of AF during the blanking period and freedom from AF off AAD at 12 months between both groups (5/17% vs 8/27%; p = 0.347 and 21/70% vs 18/60%; p=0.417 in placebo and steroid groups respectively). Although oral corticosteroids have significant effect in lowering certain cytokines, it did not impact the clinical outcomes of AF ablation.

  12. Six-month follow-up of isthmus-dependent right atrial flutter ablation using a remote magnetic catheter navigation system: a case-control study.

    PubMed

    Huo, Yan; Hindricks, Gerhard; Piorkowski, Christopher; Bollmann, Andreas; Wetzel, Ulrike; Sommer, Phillip; Gaspar, Thomas; Kottkamp, Hans; Arya, Arash

    2010-06-01

    The objective of this study was to compare results between the magnetic navigation system (MNS) and conventional catheter ablation of cavo-tricuspid isthmus (CTI)-dependent right atrial flutter (AFL) in a case control study. A remote MNS has been used for ablation of various arrhythmias including CTI-dependent AFL but comparative results between MNS and conventional ablation are not available. Between May and September 2007, a total of 51 consecutive patients (45 men, mean age 65.4 +/- 9.4 years) had undergone catheter ablation for CTI-dependent AFL. The catheter ablation (70 degrees C, 70 W, 90 s) was performed with either an 8-mm-tip magnetic catheter using MNS (case group, n = 26, 23 men, mean age 64.6 +/- 9.6 y) or a conventional 8-mm catheter (case group, n = 25, 22 men, mean age 65.4 +/- 9.1 y). Acute procedural success was defined as complete bidirectional isthmus block and success at six months was defined as absence of AFL during the six months follow-up. With respect to baseline characteristics there were no differences between the two groups. The procedure time in MNS and conventional group was [median (range)] 53 (30-130) min and 45 (30-100) min, respectively (P = 0.12). Acute success was achieved by MNS and conventional ablation in 25/26 (96.2%) and 25/25 (100%) of patients, respectively (P = 0.53). During the six months of follow-up 4 patients, 2 in each group, experienced recurrence (P = 0.90). No major complication occurred during the procedure. Charring on the catheter tip occurred in 5 patients (19.2%) in MNS and none of the patients in the control group (P <0.05). This case-control study demonstrated the acute and mid-term efficacy and safety of catheter ablation by MNS for CTI-dependent AFL, similar to rates achieved by conventional radiofrequency catheter ablation.

  13. The influence of residual apixaban on bleeding complications during and after catheter ablation of atrial fibrillation.

    PubMed

    Mukai, Yutaro; Wada, Kyoichi; Miyamoto, Koji; Nakagita, Kazuki; Fujimoto, Mai; Hosomi, Kouichi; Kuwahara, Takeshi; Takada, Mitsutaka; Kusano, Kengo; Oita, Akira

    2017-10-01

    The periprocedural protocol for atrial fibrillation (AF) ablation commonly includes anticoagulation therapy. Apixaban, a direct oral anticoagulant, is currently approved for clinical use; however, little is known about the effects of residual apixaban concentration on bleeding complications during/after AF ablation. Therefore, we measured residual apixaban concentration by using mass spectrometry and examined the anticoagulant's residual effects on bleeding complications. Fifty-eight patients (Mean age of 64.7±12.5 years; 31 males, 27 females) were enrolled and administered apixaban twice daily. We analyzed trough apixaban concentration, activated clotting time (ACT), heparin dose, and bleeding complications during/after AF ablation. Apixaban concentrations were directly measured using mass spectrometry. Bleeding complications were observed in 19 patients (delayed hemostasis at the puncture site, 16; hematuria, 3; hemosputum, 1). No patient required blood transfusion. The mean trough apixaban concentration was significantly lower in patients with bleeding complications than without (152.4±73.1 vs. 206.8±98.8 ng/mL respectively, P =0.037), while the heparin dose to achieve ACT>300 s was significantly higher in patients with bleeding complications (9368.4±2929.0 vs. 7987.2±2135.2 U/body respectively, P =0.046). Interestingly, a negative correlation was found between the trough apixaban concentration and the heparin dose to achieve ACT>300 s ( P =0.033, R=-0.281). Low residual plasma apixaban is associated with a higher incidence of bleeding complications during/after AF ablation, potentially because of a greater heparin requirement during AF ablation.

  14. Using electrical impedance to predict catheter-endocardial contact during RF cardiac ablation.

    PubMed

    Cao, Hong; Tungjitkusolmun, Supan; Choy, Young Bin; Tsai, Jang-Zern; Vorperian, Vicken R; Webster, John G

    2002-03-01

    During radio-frequency (RF) cardiac catheter ablation, there is little information to estimate the contact between the catheter tip electrode and endocardium because only the metal electrode shows up under fluoroscopy. We present a method that utilizes the electrical impedance between the catheter electrode and the dispersive electrode to predict the catheter tip electrode insertion depth into the endocardium. Since the resistivity of blood differs from the resistivity of the endocardium, the impedance increases as the catheter tip lodges deeper in the endocardium. In vitro measurements yielded the impedance-depth relations at 1, 10, 100, and 500 kHz. We predict the depth by spline curve interpolation using the obtained calibration curve. This impedance method gives reasonably accurate predicted depth. We also evaluated alternative methods, such as impedance difference and impedance ratio.

  15. Initial clinical experience with a remote magnetic catheter navigation system for ablation of cavotricuspid isthmus-dependent right atrial flutter.

    PubMed

    Arya, Arash; Kottkamp, Hans; Piorkowski, Christopher; Bollmann, Andreas; Gerdes-Li, Jin-Hong; Riahi, Sam; Esato, Masahiro; Hindricks, Gerhard

    2008-05-01

    A remote magnetic navigation system (MNS) is available and has been used with a 4-mm-tip magnetic catheter for radiofrequency (RF) ablation of some supraventricular and ventricular arrhythmias; however, it has not been evaluated for the ablation of cavotricuspid isthmus-dependent right atrial flutter (AFL). The present study evaluates the feasibility and efficiency of this system and the newly available 8-mm-tip magnetic catheter to perform RF ablation in patients with AFL. Twenty-six consecutive patients (23 men, mean age 64.6 +/- 9.6 years) underwent RF ablation using a remote MNS. RF ablation was performed with an 8-mm-tip magnetic catheter (70 degrees C, maximum power 70 W, 90 seconds). The endpoint of ablation was complete bidirectional isthmus block. To assess a possible learning curve, procedural data were compared between the first 14 (group 1) and the rest (group 2) of the patients. The initial rhythm during ablation was AFL in 20 (19 counterclockwise and 1 clockwise) and sinus rhythm in six patients. Due to technical issues, the ablation in the 18th patient could not be done with the MNS, and so we switched to conventional ablation. The remote magnetic navigation and ablation procedure was successful in 24 of the 25 (96%) remaining patients with AFL. In one patient (patient 2), conventional catheter was used to complete the isthmus block after termination of AFL. The procedure, preparation, ablation, and fluoroscopy times (median [range]) were 53 (30-130) minutes, 28 (10-65) minutes, 25 (12-78) minutes, and 7.5 (3.2-20.8) minutes, respectively. Patients in group 2 had shorter procedure (45 [30-70] min vs 80 [57-130] min, P = 0.0001), preparation (25 [10-30] min vs 42 [30-65] min, P = 0.0001), ablation (20 [12-40] min vs 31 [20-78] min, P = 0.002), and fluoroscopy (7.2 [3.2-12.2] min vs 11.0 [5.4-20.8] min, P = 0.014) times. No complication occurred during the procedure. Using a remote MNS and an 8-mm-tip magnetic catheter, ablation of AFL is feasible

  16. Catheter ablation of junctional ectopic tachycardia in children, with preservation of atrioventricular conduction.

    PubMed

    Emmel, M; Sreeram, N; Brockmeier, K

    2005-04-01

    Idiopathic junctional ectopic tachycardia is a rare arrhythmia in children. Several studies have demonstrated that drug therapy is often ineffective and sometimes the only achieved effect is rate control. Early presentation and frequent recurrence are associated with adverse outcome. Three consecutive children, aged 9, 7 and 12 years respectively, underwent radiofrequency catheter ablation for junctional ectopic tachycardia, after having failed antiarrhythmic drug therapy. The entire His bundle was plotted out and marked, using the Localisa navigation system. The arrhythmia was readily and repeatedly inducible using intravenous isoprenaline infusion and the site of earliest retrograde conduction during tachycardia could be assessed. Ablations were performed in sinus rhythm, empirically targeting the site of earliest retrograde conduction during tachycardia. This approach was successful in abolishing tachyarrhythmia in the first two patients, in whom the successful ablation site was located superoparaseptally. In the third patient, junctional ectopic tachycardia was inducible, despite abolishing retrograde atrial activation, in a septal location on the tricuspid valve annulus. Further ablations in the superoparaseptal region, closer to the His bundle, were successful in rendering tachyarrhythmia noninducible. Over a median follow-up of 10 months, none of the patients has had recurrence of arrhythmia, despite discontinuing all antiarrhythmic medications. Radio frequency catheter ablation of junctional ectopic tachycardia is feasible with preservation of atrioventricular conduction.

  17. Role of Contact Force Sensing in Catheter Ablation of Cardiac Arrhythmias: Evolution or History Repeating Itself?

    PubMed

    Ariyarathna, Nilshan; Kumar, Saurabh; Thomas, Stuart P; Stevenson, William G; Michaud, Gregory F

    2018-06-01

    Adequate catheter-tissue contact facilitates efficient heat energy transfer to target tissue. Tissue contact is thus critical to achieving lesion transmurality and success of radiofrequency (RF) ablation procedures, a fact recognized more than 2 decades ago. The availability of real-time contact force (CF)-sensing catheters has reinvigorated the field of ablation biophysics and optimized lesion formation. The ability to measure and display CF came with the promise of dramatic improvement in safety and efficacy; however, CF quality was noted to have just as important an influence on lesion formation as absolute CF quantity. Multiple other factors have emerged as key elements influencing effective lesion formation, including catheter stability, lesion contiguity and continuity, lesion density, contact homogeneity across a line of ablation, spatiotemporal dynamics of contact governed by cardiac and respiratory motion, contact directionality, and anatomic wall thickness, in addition to traditional ablation indices of power and RF duration. There is greater appreciation of surrogate markers as a guide to lesion formation, such as impedance fall, loss of pace capture, and change in unipolar electrogram morphology. In contrast, other surrogates such as tactile feedback, catheter motion, and electrogram amplitude are notably poor predictors of actual contact and lesion formation. This review aims to contextualize the role of CF sensing in lesion formation with respect of the fundamental principles of biophysics of RF ablation and summarize the state-of-the-art evidence behind the role of CF in optimizing lesion formation. Copyright © 2018 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  18. Catheter-based high-intensity ultrasound for epicardial ablation of the left ventricle: device design and in vivo feasiblity

    NASA Astrophysics Data System (ADS)

    Salgaonkar, Vasant A.; Nazer, Babak; Jones, Peter D.; Tanaka, Yasuaki; Martin, Alastair; Ng, Bennett; Duggirala, Srikant; Diederich, Chris J.; Gerstenfeld, Edward P.

    2015-03-01

    The development and in vivo testing of a high-intensity ultrasound thermal ablation catheter for epicardial ablation of the left ventricle (LV) is presented. Scar tissue can occur in the mid-myocardial and epicardial space in patients with nonischemic cardiomyopathy and lead to ventricular tachycardia. Current ablation technology uses radiofrequency energy, which is limited epicardially by the presence of coronary vessels, phrenic nerves, and fat. Ultrasound energy can be precisely directed to deliver targeted deep epicardial ablation while sparing intervening epicardial nerve and vessels. The proof-of-concept ultrasound applicators were designed for sub-xyphoid access to the pericardial space through a steerable 14-Fr sheath. The catheter consists of two rectangular planar transducers, for therapy (6.4 MHz) and imaging (5 MHz), mounted at the tip of a 3.5-mm flexible nylon catheter coupled and encapsulated within a custom-shaped balloon for cooling. Thermal lesions were created in the LV in a swine (n = 10) model in vivo. The ultrasound applicator was positioned fluoroscopically. Its orientation and contact with the LV were verified using A-mode imaging and a radio-opaque marker. Ablations employed 60-s exposures at 15 - 30 W (electrical power). Histology indicated thermal coagulation and ablative lesions penetrating 8 - 12 mm into the left ventricle on lateral and anterior walls and along the left anterior descending artery. The transducer design enabled successful sparing from the epicardial surface to 2 - 4 mm of intervening ventricle tissue and epicardial fat. The feasibility of targeted epicardial ablation with catheter-based ultrasound was demonstrated.

  19. Left Atrial Size and Left Ventricular End-Systolic Dimension Predict the Progression of Paroxysmal Atrial Fibrillation After Catheter Ablation.

    PubMed

    Liao, Ying-Chieh; Liao, Jo-Nan; Lo, Li-Wei; Lin, Yenn-Jiang; Chang, Shih-Lin; Hu, Yu-Feng; Chao, Tze-Fan; Chung, Fa-Po; Tuan, Ta-Chuan; Te, Abigail Louise D; Walia, Rohit; Yamada, Shinya; Lin, Chung-Hsing; Lin, Chin-Yu; Chang, Yao-Ting; Allamsetty, Suresh; Yu, Wen-Chung; Huang, Jing-Long; Wu, Tsu-Juey; Chen, Shih-Ann

    2017-01-01

    Although rare, some paroxysmal atrial fibrillations (AF) still progress despite radiofrequency (RF) ablation. In the study, we evaluated the long-term efficacy of RF ablation and the predictors of AF progression. A total of 589 paroxysmal AF patients (404 men and 185 women; aged 54 ± 12 years) who received 3-dimensional mapping and ablation were enrolled. Their clinical parameters and electrophysiological characteristics were collected. They were divided into Group 1 (N = 13, with AF progression) and Group 2 (N = 576, no AF progression). AF progression was defined as recurrence of persistent AF. Group 1 patients had larger left atrial (LA) diameter, larger left ventricle (LV) end-systolic and end-diastolic diameters, poorer LV systolic function, and more amiodarone use at baseline. After 1.2 ± 0.5 procedures, 123 (21%) patients experienced recurrence during 56 ± 29 months' follow-up. In the multivariate analysis, LA diameter (P = 0.018, HR = 1.12, 95% CI = 1.02-1.24) and LV end-systolic diameter (P = 0.005, HR = 1.10, 95% CI = 1.03-1.17) independently predicted AF progression. LA diameter >43 mm and LV end-systolic diameter >31 mm were the best cut-off values for predicting AF progression by ROC analysis. AF progression rate achieved 19% if they had both larger LA diameter (>43 mm) and LV end-systolic diameter (>31 mm). RF ablation prevents the progression of paroxysmal AF effectively, except in patients with increased LA diameter and LV end-systolic diameter on echocardiogram, suggesting more aggressive rhythm control therapies should be considered in these patients. © 2016 Wiley Periodicals, Inc.

  20. Ablation of "Background Tachycardia" in Long Standing Atrial Fibrillation: Improving the Outcomes by Unmasking a Residual Atrial Fibrillation Perpetuator.

    PubMed

    Pachón-M, José Carlos; Pachón-M, Enrique I; Santillana P, Tomas G; Lobo, Tasso Julio; Pachón, Carlos Thiene C; Pachón-M, Juán Carlos; Albornoz V, Remy Nelson; Zerpa A, Juán Carlos; Ortencio, Felipe; Arruda, Mauricio

    2017-01-01

    Catheter ablation of long-standing persistent AF (LSAF) remains challenging. Since AF-Nest (AFN) description, we have observed that a stable, protected, fast source firing, namely "Background Tachycardia"(BT), could be hidden beneath the chaotic AF. Following pulmonary vein isolation (PVI)+AFN ablation one or more BT may arise or be induced in 30-40% of patients, which could be the culprit forAF maintenance and ablation recurrences. We studied 114 patients, from 322 sequential LSAF regular ablations, having spontaneous or induced residual BT after EGM-guided PVI+AFN ablation of LSAF; 55.6±11y/o, 97males (85.1%), EF=65.5±8%, LA=42.8±6.7mm. Macroreentrant tachycardias were excluded. Pre-ablationAF 12-leads ECG Digital processing(DP) and spectral analysis(SA) was performed searching for BT before AF ablation and its correlation with BT during ablation.After PVI, 38.1±9 AFN sites/patient and 135 sustained BTs (1-3, 1.2±0.5/patient) were ablated. BT cycle length(CL) was 246.3±37.3ms. In 79 patients presenting suitable DP for SA, the BT-CL was 241.6±34.3ms with intra procedure BT-CL correlation r=0.83/p<0.01. Following BT ablation, AF could not be induced. During FU of 13→60 months(22.8±12m), AF freedom for BT RF(+) vs. BT RF(-) groups were 77.9% vs. 56.4% (p=0.009), respectively. There was no significant complication. BT ablation following PVI and AFN ablation improved long-term outcomes ofLSAF ablation. BT is likely due to sustained microreentry, protected during AF by entry block. BT can be suspected by spectral analysis of the pre-ablation ECG and is likely one important AF perpetuator by causing electrical resonance of the AFN. This ablation strategy warrants randomized, multicenter investigation.

  1. Electroanatomic Mapping-Guided Catheter Ablation of Supraventricular Tachycardia in Children with Ebstein's Anomaly.

    PubMed

    Ergul, Yakup; Koca, Serhat; Akdeniz, Celal; Tuzcu, Volkan

    2018-06-07

    In Ebstein's anomaly (EA), tachycardia substrates are complex, and accessory pathway (AP) ablations are often challenging. This study demonstrates the utility of the EnSite Velocity system (St. Jude Medical, St Paul, MN) in the catheter ablation of supraventricular tachycardia in children with EA. Twenty patients [Female/Male = 8/12, median age 11.5 years (2.6-18)] with EA who underwent catheter ablation guided by the EnSite Velocity system between December 2011 and December 2016 were retrospectively evaluated. Five patients had severe EA, and two of them were at Fontan palliation pathway. The most common indications for ablations were palpitations/syncope and treatment-resistant arrhythmias. Thirty-one tachycardia substrate foci (21 manifest AP, 2 concealed AP, 4 Mahaim AP, 3 focal atrial tachycardias, and 1 typical atrioventricular nodal reentrant tachycardia) were detected in 20 patients. There were multiple tachycardia substrates in 11 patients (55%). The patient-based acute procedure success rate was 19/20 (95%), and the tachycardia-based success rate was 30/31 (97%). The mean procedure time was 170 ± 43 min (90-265). Fluoroscopy was not used in 15 (75%) patients. The mean fluoroscopy time in the remaining five patients was 3.6 ± 2.9 min (0.7-7.8). During a mean follow-up of 35.1 ± 20.3 months (6-60), tachycardia recurred in four patients (4/19, 21%). No complications were seen. Catheter ablation of arrhythmias can be performed effectively and safely in pediatric EA patients by using a limited fluoroscopic approach with the help of electroanatomical mapping systems. However, the rate of tachycardia recurrence at follow-up remains high.

  2. Long-term influence of body mass index on cardiovascular events after atrial fibrillation ablation.

    PubMed

    Bunch, T Jared; May, Heidi T; Bair, Tami L; Crandall, Brian G; Cutler, Michael J; Jacobs, Victoria; Mallender, Charles; Muhlestein, Joseph B; Osborn, Jeffrey S; Weiss, J Peter; Day, John D

    2016-09-01

    Catheter ablation of atrial fibrillation (AF) is an established therapeutic rhythm approach in symptomatic patients. Obesity is a dominant driver of AF recurrence after ablation. However, being both overweight and underweight drives long-term cardiac and general health risks. Long-term data are needed to understand the influence of body mass index (BMI) on outcomes after ablation in regard to arrhythmia recurrence and cardiovascular outcomes. All patients who underwent an index ablation with a BMI recorded and at least 3 years of follow-up were included (n = 1558). The group was separated and compared by index ablation BMI status (≤20, 21-25, 26-30, >30 kg/m(2)). Long-term outcomes included AF recurrence, stroke/TIA, heart failure (HF) hospitalization, and death. Patients with advancing BMI status were more likely to be male and have hypertension, a smoking history, diabetes, HF, and a prior cardioversion. Patients with a BMI ≤20 were more likely to have a moderate-high congestive heart failure, hypertension, age >75, diabetes, stroke (CHADS2) score. At 3 years, recurrence rates of AF increased significantly with increasing BMI status (p = 0.02); paradoxically, there was a trend for increased stroke risk with decreasing BMI (p = 0.06). Long-term death rates tended to increase inversely with BMI status, and HF rates were greatest in the highest and lowest BMI groups. Lower weight at AF ablation lowers arrhythmia recurrence risk. However, AF ablation patients who are normal or underweight remain at high risk of other cardiovascular outcomes including increased stroke risk with less AF burden.

  3. Evaluation of left ventricular scar identification from contrast enhanced magnetic resonance imaging for guidance of ventricular catheter ablation therapy

    NASA Astrophysics Data System (ADS)

    Rettmann, M. E.; Lehmann, H. I.; Johnson, S. B.; Packer, D. L.

    2016-03-01

    Patients with ventricular arrhythmias typically exhibit myocardial scarring, which is believed to be an important anatomic substrate for reentrant circuits, thereby making these regions a key target in catheter ablation therapy. In ablation therapy, a catheter is guided into the left ventricle and radiofrequency energy is delivered into the tissue to interrupt arrhythmic electrical pathways. Low bipolar voltage regions are typically localized during the procedure through point-by-point construction of an electroanatomic map by sampling the endocardial surface with the ablation catheter and are used as a surrogate for myocardial scar. This process is time consuming, requires significant skill, and has the potential to miss low voltage sites. This has led to efforts to quantify myocardial scar preoperatively using delayed, contrast-enhanced MRI. In this paper, we evaluate the utility of left ventricular scar identification from delayed contrast enhanced magnetic resonance imaging for guidance of catheter ablation of ventricular arrhythmias. Myocardial infarcts were created in three canines followed by a delayed, contrast enhanced MRI scan and electroanatomic mapping. The left ventricle and myocardial scar is segmented from preoperative MRI images and sampled points from the procedural electroanatomical map are registered to the segmented endocardial surface. Sampled points with low bipolar voltage points visually align with the segmented scar regions. This work demonstrates the potential utility of using preoperative delayed, enhanced MRI to identify myocardial scarring for guidance of ventricular catheter ablation therapy.

  4. Effects of radiofrequency catheter ablation on left ventricular structure and function in patients with atrial fibrillation: a meta-analysis.

    PubMed

    Zhu, Pengju; Zhang, Yong; Jiang, Peiqing; Wang, Zhongsu; Wang, Jiangrong; Yin, Xiangcui; Hou, Yinglong

    2014-08-01

    Radiofrequency catheter ablation (RFCA) is an effective therapy for atrial fibrillation (AF). This study was designed to investigate the effects of RFCA on left ventricular (LV) structure and function in AF patients. A systematic literature search in MEDLINE, EMBASE, and Cochrane Central Register of Controlled Trials was performed to identify trials involving changes of LV structure and function in AF patients undergoing RFCA. Effect size was expressed as weighted mean difference (WMD) with 95% confidence interval (CI). LV end-diastolic diameter (LVEDD), LV end-systolic diameter (LVESD), LV end-diastolic volume (LVEDV), LV end-systolic volume (LVESV), and LV ejection fraction (LVEF) were estimated. A total of 21 trials including 1,135 participants were qualified for this meta-analysis. Compared to the baseline values, there were significant decreases in LVEDV (WMD, -6.39 ml; 95%CI, -12.46 to -0.33) and LVESV (WMD, -6.39 ml; 95%CI, -11.35 to -1.42) and a significant improvement in LVEF (WMD, 6.23%; 95%CI, 3.70 to 8.75), but no significant changes were observed in LVEDD (WMD, -0.64 mm; 95%CI, -2.40 to 1.13) and LVESD (WMD, -0.38 mm; 95%CI, -1.32 to 0.56) after RFCA. Subgroup analysis demonstrated that patients with low LVEF (WMD, 11.90%; 95%CI, 9.16 to 14.64) gained more benefits than those with normal LVEF (WMD, 1.56%; 95%CI, 0.38 to 2.74). Besides, patients with chronic AF (WMD, 10.96%; 95%CI, 4.92 to 17.01) improved more than those with paroxysmal AF (WMD, 1.93%; 95%CI, -0.27 to 4.12). RFCA in AF patients could reverse LV structural remodeling and improve LV systolic function, especially in patients with low LVEF and chronic AF.

  5. Causes and Predictors of Readmission in Patients With Atrial Fibrillation Undergoing Catheter Ablation: A National Population-Based Cohort Study.

    PubMed

    Arora, Shilpkumar; Lahewala, Sopan; Tripathi, Byomesh; Mehta, Varshil; Kumar, Varun; Chandramohan, Divya; Lemor, Alejandro; Dave, Mihir; Patel, Nileshkumar; Patel, Nilay V; Palamaner Subash Shantha, Ghanshyam; Viles-Gonzalez, Juan; Deshmukh, Abhishek

    2018-06-15

    Reducing readmission after catheter ablation (CA) in atrial fibrillation (AF) is important. We utilized National Readmission Data (NRD) 2010-2014. AF was identified by International Classification of Diseases, Ninth Edition, Clinical Modification (ICD-9-CM) diagnostic code 427.31 in the primary field, while first CA of AF was identified via ICD-9 -procedure code 37.34. Any admission within 30 or 90 days of index admission was considered a readmission. Cox proportional hazard regression was used to adjust for confounders. The primary outcomes were 30- and 90-day readmissions and the secondary outcome was AF recurrence. In total, 1 128 372 patients with AF were identified from January 1, 2010 to September 30, 2014. Of which 37 360 (3.3%) underwent CA. Patients aged ≥65 years and female sex were less likely to receive CA for AF. Overall, 10.9% and 16.5% of CA patients were readmitted within 30 and 90 days post-CA, respectively. Most common causes of readmissions were arrhythmia (AF, atrial flutter), heart failure, pulmonary causes (pneumonia, chronic obstructive pulmonary disease) and bleeding complications (gastrointestinal bleed, intracranial hemorrhage). Patients with diabetes mellitus, heart failure, coronary artery disease (CAD), chronic pulmonary and kidney disease, prior stroke/transient ischemic attack (TIA), female sex, length of stay ≥2 and disposition to the facility were prone to higher 30- and 90-day readmissions post-CA. Predictors of increase in AF recurrence post-CA were female sex, diabetes mellitus, chronic pulmonary disease, and length of stay ≥2. Trends of 90-day readmission and AF recurrence were found to improve over the study period. We identified several demographic and clinical factors associated with the use of CA in AF, and short-term outcomes of the same, which could potentially help in the patient selection and improve outcomes. © 2018 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley.

  6. [Electrophysiological findings and ablation strategies in patients with atrial tachyarrhythmias after left atrial circumferential ablation in the treatment of atrial fibrillation].

    PubMed

    Chen, Ming-long; Yang, Bing; Xu, Dong-jie; Zou, Jian-gang; Shan, Qi-jun; Chen, Chun; Chen, Hong-wu; Li, Wen-qi; Cao, Ke-jiang

    2007-02-01

    To report the electrophysiological findings and the ablation strategies in patients with atrial tachyarrhythmias (ATAs) or atrial fibrillation (AF) recurrence after left atrial circumferential ablation (LACA) in the treatment of AF. 91 patients with AF had LACA procedure from April 2004 to May 2006, 19 of which accepted the second ablation procedure due to ATAs or AF recurrence. In all the 19 patients [17 male, 2 female, age 25 - 65 (53 +/- 12) years], 11 presented with paroxysmal AF before the first ablation procedure, 2 with persistent AF and 6 with permanent AF. Pulmonary vein potentials (PVP) were investigated in both sides in all the patients. Delayed PVP was identified inside the left circular line in 5 patients, in the right in 1 and both in 2 during sinus rhythm. "Gap" conduction was found and successfully closed guided by circular mapping catheter. In 3 cases, irregular left atrial tachycardia was caused by fibrillation rhythm inside the left ring via decremental "gap" conduction. Reisolation was done successfully again guided by 3-D mapping and made the left atrium in sinus rhythm but the fibrillation rhythm was still inside the left ring. Pulmonary vein tachycardia with 1:1 conduction to the left atrium presented in one case and reisolation stopped the tachycardia. No PVP was discovered in both sides in 4 patients but other tachycardias could be induced, including two right atrial scar related tachycardias, two supraventricular tachycardias mediated by concealed accessory pathway, one cavo-tricuspid isthmus dependent atrial flutter and one focal atrial tachycardia near the coronary sinus ostium. All the tachycardias in these 4 patients were successfully ablated with the help of routine and 3-D mapping techniques. In the rest 3, which were in AF rhythm, LACA was successfully done again. After a mean follow-up of 4 - 26 (11.5 +/- 8.5) months, 16 patients were symptom free without anti-arrhythmic drug therapy; 1 of them had frequent palpitation attack with

  7. Thermal distribution of microwave antenna for atrial fibrillation catheter ablation.

    PubMed

    Zhang, Huijuan; Nan, Qun; Liu, Youjun

    2013-09-01

    The aim of this study is to investigate the effects of ablation parameters on thermal distribution during microwave atrial fibrillation catheter ablation, such as ablation time, ablation power, blood condition and antenna placement, and give proper ablative parameters to realise transmural ablation. In this paper, simplified 3D antenna-myocardium-blood finite element method models were built to simulate the endocardial ablation operation. Thermal distribution was obtained based on the coupled electromagnetic-thermal analysis. Under different antenna placement conditions and different microwave power inputs within 60 s, the lesion dimensions (maximum depth, maximum width) of the ablation zones were analysed. The ablation width and depth increased with the ablation time. The increase rate significantly slowed down after 10 s. The maximum temperature was located in 1 mm under the antenna tip when perpendicular to the endocardium, while 1.5 mm away from the antenna axis and 26 mm along the antenna (with antenna length about 30 mm) in the myocardium when parallel to the endocardium. The maximum temperature in the ablated area decreased and the effective ablation area (with the temperature raised to 50°C) shifted deeper into the myocardium due to the blood cooling. The research validated that the microwave antenna can provide continuous long and linear lesions for the treatment of atrial fibrillation. The dimensions of the created lesion widths were all larger than those of the depths. It is easy for the microwave antenna to produce transmural lesions for an atrial wall thickness of 2-6 mm by adjusting the applied power and ablation time.

  8. Stiff Left Atrial Syndrome: A Complication Undergoing Radiofrequency Catheter Ablation for Atrial Fibrillation.

    PubMed

    Yang, Yufan; Liu, Qiming; Wu, Zhihong; Li, Xuping; Xiao, Yichao; Tu, Tao; Zhou, Shenghua

    2016-07-01

    Radiofrequency catheter ablation for atrial fibrillation is an effective approach for treating atrial fibrillation. Its complications have attracted much attention, of which the stiff left atrial syndrome is a recently discovered complication that has not been completely understood. This study aims to investigate the concept, pathologic basis, clinical characteristics, predictors, and treatment protocols of the stiff left atrial syndrome after radiofrequency ablation for atrial fibrillation. © 2016 Wiley Periodicals, Inc.

  9. Radiofrequency Catheter Ablation for Atrial Fibrillation Elicited "Jackhammer Esophagus": A New Complication Due to Vagal Nerve Stimulation?

    PubMed

    Tolone, Salvatore; Savarino, Edoardo; Docimo, Ludovico

    2015-10-01

    Radiofrequency catheter ablation (RFCA) is a potentially curative method for treatment of highly symptomatic and drug-refractory atrial fibrillation (AF). However, this technique can provoke esophageal and nerve lesion, due to thermal injury. To our knowledge, there have been no reported cases of a newly described motor disorder, the Jackhammer esophagus (JE) after RFCA, independently of GERD. We report a case of JE diagnosed by high-resolution manometry (HRM), in whom esophageal symptoms developed 2 weeks after RFCA, in absence of objective evidence of GERD. A 65-year-old male with highly symptomatic, drug-refractory paroxysmal AF was candidate to complete electrical pulmonary vein isolation with RFCA. Prior the procedure, the patient underwent HRM and impedance-pH to rule out GERD or hiatal hernia presence. All HRM parameters, according to Chicago classification, were within normal limits. No significant gastroesophageal reflux was documented at impedance pH monitoring. Patient underwent RFCA with electrical disconnection of pulmonary vein. After two weeks, patient started to complain of dysphagia for solids, with acute chest-pain. The patient repeated HRM and impedance-pH monitoring 8 weeks after RFCA. HRM showed in all liquid swallows the typical spastic hypercontractile contractions consistent with the diagnosis of JE, whereas impedance-pH monitoring resulted again negative for GERD. Esophageal dysmotility can represent a possible complication of RFCA for AF, probably due to a vagal nerve injury, and dysphagia appearance after this procedure must be timely investigated by HRM.

  10. Impact of Voltage Mapping to Guide Whether to Perform Ablation of the Posterior Wall in Patients With Persistent Atrial Fibrillation.

    PubMed

    Cutler, Michael J; Johnson, Jeremy; Abozguia, Khalid; Rowan, Shane; Lewis, William; Costantini, Otto; Natale, Andrea; Ziv, Ohad

    2016-01-01

    Fibrosis as a substrate for atrial fibrillation (AF) has been shown in numerous preclinical models. Voltage mapping enables in vivo assessment of scar in the left atrium (LA), which can be targeted with catheter ablation. We hypothesized that using the presence or absence of low voltage to guide ablation beyond pulmonary vein antral isolation (PVAI) will improve atrial arrhythmia (AF/AT)-free survival in persistent AF. Single-center retrospective analysis of 2 AF ablation strategies: (1) standard ablation (SA) versus (2) voltage-guided ablation (VGA). PVAI was performed in both groups. With SA, additional lesions beyond PVAI were performed at the discretion of the operator. With VGA, additional lesions to isolate the LA posterior wall were performed if voltage mapping of this region in sinus rhythm showed scar (LA voltage < 0.5 mV). AF-/AT-free endpoint was defined as no sustained AF/AT seen off antiarrhythmic medications after a 2-month postablation blanking period. Seventy-six patients underwent SA and 65 underwent VGA. Patients were well matched for comorbidities, LVEF, and left atrial size. Posterior wall ablation was performed in 57% of patient with SA compared to 42% with VGA. VGA ablation increased 1-year AF-/AT-free survival in patients when compared to SA (80% vs. 57%; P = 0.005). In a multivariate analysis, VGA was the only independent predictor of AF-/AT-free survival (hazard ratio of 0.30; P = 0.002). The presence of LA posterior wall scar may be an important ablation target in persistent AF. A prospective randomized trial is needed to confirm these data. © 2015 Wiley Periodicals, Inc.

  11. Left atrial low-voltage areas predict atrial fibrillation recurrence after catheter ablation in patients with paroxysmal atrial fibrillation.

    PubMed

    Masuda, Masaharu; Fujita, Masashi; Iida, Osamu; Okamoto, Shin; Ishihara, Takayuki; Nanto, Kiyonori; Kanda, Takashi; Tsujimura, Takuya; Matsuda, Yasuhiro; Okuno, Shota; Ohashi, Takuya; Tsuji, Aki; Mano, Toshiaki

    2018-04-15

    Association between the presence of left atrial low-voltage areas and atrial fibrillation (AF) recurrence after pulmonary vein isolation (PVI) has been shown mainly in persistent AF patients. We sought to compare the AF recurrence rate in paroxysmal AF patients with and without left atrial low-voltage areas. This prospective observational study included 147 consecutive patients undergoing initial ablation for paroxysmal AF. Voltage mapping was performed after PVI during sinus rhythm, and low-voltage areas were defined as regions where bipolar peak-to-peak voltage was <0.50mV. Left atrial low-voltage areas after PVI were observed in 22 (15%) patients. Patients with low-voltage areas were significantly older (72±6 vs. 66±10, p<0.0001), more likely to be female (68% vs. 32%, p=0.002), and had higher CHA 2 DS 2 -VASc score (2.5±1.5 vs. 1.8±1.3, p=0.028). During a mean follow-up of 22 (18, 26) months, AF recurrence was observed in 24 (16%) and 16 (11%) patients after the single and multiple ablation procedures, respectively. AF recurrence rate after multiple ablations was higher in patients with low-voltage areas than without (36% vs. 6%, p<0.001). Low-voltage areas were independently associated with AF recurrence even after adjustment for the other related factors (Hazard ratio, 5.89; 95% confidence interval, 2.16 to 16.0, p=0.001). The presence of left atrial low-voltage areas after PVI predicts AF recurrence in patients with paroxysmal AF as well as in patients with persistent AF. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. Initial clinical experience of remote magnetic navigation system for catheter mapping and ablation of supraventricular tachycardias.

    PubMed

    Xu, Dongjie; Yang, Bin; Shan, Qijun; Zou, Jiangang; Chen, Minglong; Chen, Chun; Hou, Xiaofeng; Zhang, Fengxiang; Li, Wen-Qi; Cao, Kejiang; Tse, Hung-Fat

    2009-09-01

    A remote magnetic navigation system (MNS) has been developed for mapping and catheter ablation of cardiac arrhythmias. The present study evaluates the safety and feasibility of this system to perform radiofrequency (RF) ablation in patients with supraventricular tachycardias (SVT). A total of 32 patients (22 female; mean age 44 +/- 16 years) with documented SVT underwent mapping and ablation using Helios II (a 4-mm-tip magnetic catheter), under the guidance of the MNS (Niobe II, Stereotaxis, Inc.). Catheter ablation procedure with MNS was successful in 30/32 (94%) patients including all patients (27/27, 100%) with atrioventricular nodal reentrant tachycardia (AVNRT) and three of five patients (60%) with atrioventricular reentrant tachycardia (AVRT) without any complication. The procedural successful rate in patients with AVNRT was significantly higher than those in patients with AVRT (P < 0.001). Overall, the medium number of RF application using the MNS was 2 (mean 2.7 +/- 1.6, range 1 to 7), and the medium numbers of RF for AVNRT and AVRT were 2 and 3, respectively. There was no significant difference in the mean procedural time between patients with AVNRT and AVRT (126.3 +/- 38.6 vs. 138.0 +/- 40.3 min, P = 0.54). However, the mean fluoroscopy time was significantly shorter in patients with AVNRT than those with AVRT (5.7 +/- 3.0 vs. 16.5 +/- 2.5 min, P < 0.001). Among those patients with AVNRT, the mean procedural time (139.3 +/- 45.0 vs. 112.3 +/- 24.9 min, P = 0.07) and fluoroscopic time (3.2 +/- 1.0 vs. 8.0 +/- 2.2 min, P < 0.001) were shorter for the later 13 patients than the first 14 patients, suggesting a learning curve in using the MNS for RF ablation. The Niobe MNS is a new technique that can allow safe and effective remote-controlled navigation and minimize the need for fluoroscopic guidance for ablation catheter of AVNRT. However, further improvement is required to achieve a higher successful rate for treatment of AVRT.

  13. A new catheter design for combined radiofrequency ablation and optoacoustic treatment monitoring using copper-coated light-guides

    NASA Astrophysics Data System (ADS)

    Rebling, Johannes; Oyaga Landa, Francisco Javier; Deán-Ben, Xosé Luis; Razansky, Daniel

    2018-02-01

    Electrosurgery, i.e. the application of radiofrequency current for tissue ablation, is a frequently used treatment for many cardiac arrhythmias. Electrophysiological and anatomic mapping, as well as careful radiofrequency power control typically guide the radiofrequency ablation procedure. Despite its widespread application, accurate monitoring of the lesion formation with sufficient spatio-temporal resolution remains challenging with the existing imaging techniques. We present a novel integrated catheter for simultaneous radiofrequency ablation and optoacoustic monitoring of the lesion formation in real time and 3D. The design combines the delivery of both electric current and optoacoustic excitation beam in a single catheter consisting of copper-coated multimode light-guides and its manufacturing is described in detail. The electrical current causes coagulation and desiccation while the excitation light is locally absorbed, generating OA responses from the entire treated volume. The combined ablation-monitoring capabilities were verified using ex-vivo bovine tissue. The formed ablation lesions showed a homogenous coagulation while the ablation was monitored in realtime with a volumetric frame rate of 10 Hz over 150 seconds.

  14. Radiation exposure to operator and patients during cardiac electrophysiology study, radiofrequency catheter ablation and cardiac device implantation procedures

    NASA Astrophysics Data System (ADS)

    Lee, C. H.; Cho, J. H.; Park, S. J.; Kim, J. S.; On, Y. K.; Huh, J.

    2015-10-01

    The purpose of this study was to measure the radiation exposure to operator and patient during cardiac electrophysiology study, radiofrequency catheter ablation and cardiac device implantation procedures and to calculate the allowable number of cases per year. We carried out 9 electrophysiology studies, 40 radiofrequency catheter ablation and 11 cardiac device implantation procedures. To measure occupational radiation dose and dose-area product (DAP), 13 photoluminescence glass dosimeters were placed at eyes (inside and outside lead glass), thyroids (inside and outside thyroid collar), chest (inside and outside lead apron), wrists, genital of the operator (inside lead apron), and 6 of photoluminescence glass dosimeters were placed at eyes, thyroids, chest and genital of the patient. Exposure time and DAP values were 11.7 ± 11.8 min and 23.2 ± 26.2 Gy cm2 for electrophysiology study; 36.5 ± 42.1 min and 822.4 ± 125.5 Gy cm2 for radiofrequency catheter ablation; 16.2 ± 9.3 min and 27.8 ± 16.5 Gy cm2 for cardiac device implantation procedure, prospectively. 4591 electrophysiology studies can be conducted within the occupational exposure limit for the eyes (150 mSv), and 658-electrophysiology studies with radiofrequency catheter ablation can be carried out within the occupational exposure limit for the hands (500 mSv). 1654 cardiac device implantation procedure can be conducted within the occupational exposure limit for the eyes (150 mSv). The amounts of the operator and patient's radiation exposure were comparatively small. So, electrophysiology study, radio frequency catheter ablation and cardiac device implantation procedures are safe when performed with modern equipment and optimized protective radiation protect equipment.

  15. The quest for durable lesions in catheter ablation of atrial fibrillation - technological advances in radiofrequency catheters and balloon devices.

    PubMed

    Maurer, Tilman; Kuck, Karl-Heinz

    2017-08-01

    Atrial fibrillation is the most common cardiac arrhythmia and represents a growing clinical, social and economic challenge. Catheter ablation for symptomatic atrial fibrillation has evolved from an experimental procedure into a widespread therapy and offers a safe and effective treatment option. A prerequisite for durable PVI are transmural and contiguous circumferential lesions around the pulmonary veins. However, electrical reconnection of initially isolated pulmonary veins remains a primary concern and is a dominant factor for arrhythmia recurrence during long-term follow up. Areas covered: This article discusses the physiology of lesion formation using radiofrequency-, cryo- or laser- energy for pulmonary vein isolation and provides a detailed review of recent technological advancements in the field of radiofrequency catheters and balloon devices. Finally, future directions and upcoming developments for the interventional treatment of atrial fibrillation are discussed. Expert commentary: Durable conduction block across deployed myocardial lesions is mandatory not only for PVI but for any other cardiac ablation strategy as well. A major improvement urgently expected is the intraprocedural real-time distinction of durable lesions from interposed gaps with only transiently impaired electrical conduction. Furthermore, a simplification of ablation tools used for PVI is required to reduce the high technical complexity of the procedure.

  16. Foley catheter balloon endometrial ablation: successful treatment of three cases.

    PubMed

    Api, Murat; Api, Olus

    2012-03-01

    Endometrial ablation is one of the most effective methods for treatment of dysfunctional uterine bleeding (DUB). Balloon devices with circulating hot water inside or electrodes on the outer surface and radiofrequency-induced thermal destructors are the most recently introduced available tools for endometrial ablation. All of these methods are effective and simple but expensive technologies. The aim of this brief report is to evaluate the effectiveness and safety of a new, simple and money-saving procedure, namely foley catheter balloon endometrial ablation (FCBEA), for treatment of DUB. We present our experience with FCBEA performed on 3 women with severe meno-metrorrhagia unresponsive to medical therapy. There were no procedure-related complications with achievement of complete amenorrhea for a 19 months follow-up period. Although FCBA has yielded encouraging results, there exists a need for further investigation and validation on larger groups, before its universal application.

  17. Idiopathic ventricular outflow tract arrhythmias from the great cardiac vein: challenges and risks of catheter ablation.

    PubMed

    Steven, D; Pott, C; Bittner, A; Sultan, A; Wasmer, K; Hoffmann, B A; Köbe, J; Drewitz, I; Milberg, P; Lueker, J; Mönnig, G; Servatius, H; Willems, S; Eckardt, L

    2013-11-20

    Catheter ablation for idiopathic ventricular arrhythmia is well established but epicardial origin, proximity to coronary arteries, and limited accessibility may complicate ablation from the venous system in particular from the great cardiac vein (GCV). Between April 2009 and October 2010 14 patients (56 ± 15 years; 9 male) out of a total group of 117 patients with idiopathic outflow tract tachycardias were included undergoing ablation for idiopathic VT or premature ventricular contractions (PVC) originating from GCV. All patients in whom the PVC arose from the GCV were subject to the study. In these patients angiography of the left coronary system was performed with the ablation catheter at the site of earliest activation. Successful ablation was performed in 6/14 (43%) and long-term success was achieved in 5/14 (36%) patients. In 4/14 patients (28.6%) ablation was not performed. In another 4 patients (26.7%), ablation did not abolish the PVC/VT. In the majority, the anatomical proximity to the left coronary system prohibited effective RF application. In 3 patients RF application resulted in a coronary spasm with complete regression as revealed in repeat coronary angiography. A relevant proportion idiopathic VT/PVC can safely be ablated from the GCV without significant permanent coronary artery stenosis after RF application. Our data furthermore demonstrate that damage to the coronary artery system is likely to be transient. © 2013.

  18. Outcome of Radiofrequency Catheter Ablation as a non-pharmacological therapy for idiopathic Ventricular Tachycardia.

    PubMed

    Samore, Naseer Ahmed; Imran Majeed, Syed Muhammad; Kayani, Azhar Mahmud; Bhalli, Muhammad Asif; Shabbir, Muhammad

    2009-09-01

    To determine the outcome of Radiofrequency Catheter Ablation (RFCA) as a non-pharmacological curative therapy for idiopathic Ventricular Tachycardia (VT) and to identify procedure-related complications. Descriptive study. The Armed Forces Institute of Cardiology and National Institute of Heart Diseases, Rawalpindi, from February 2001 to October 2008. Ninety eight consecutive patients with idiopathic VT, resistant to drug therapy, who underwent Electrophysiology Studies (EPS) radiofrequency catheter ablation were enrolled. Clinical and electrophysiological variables were recorded and a descriptive analysis was done. Out of the 98 patients, 79 were males (80.6%). The mean age was 33.29+11.93 years. Modes of presentation were sustained VT, Repetitive Monomorphic VT (RMVT), Non-sustained VT (NSVT) and Ventricular Premature Beats (VPBs). Right Ventricular Outflow Tract (RVOT) VT was found in 37 patients, 37 had Idiopathic Left Ventricular Tachycardia (ILVT), 20 had Left Ventricular Outflow Tract (LVOT) VT, and Inflow Right Ventricular Tachycardia (IRVT) was found in 7 patients. Other sites of origin of VT were infrequent. Eight patients had dual morphologies of VT. Atrioventricular Nodal Re-entry Tachycardia (AVNRT) was found in 8 patients. RFCA was successful in abolishing inducible VT in 88 patients. One patient developed complete AV block requiring a permanent pacemaker. Results of this study confirm a high degree of success and safety of radiofrequency catheter ablation as curative therapy for idiopathic ventricular tachycardia.

  19. Wholly Patient-tailored Ablation of Atrial Fibrillation Guided by Spatio-Temporal Dispersion of Electrograms in the Absence of Pulmonary Veins Isolation

    PubMed Central

    Seitz, Julien; Bars, Clément; Théodore, Guillaume; Beurtheret, Sylvain; Lellouche, Nicolas; Bremondy, Michel; Ferracci, Ange; Faure, Jacques; Penaranda, Guillaume; Yamazaki, Masatoshi; Avula, Uma Mahesh R.; Curel, Laurence; Siame, Sabrina; Berenfeld, Omer; Pisapia, André; Kalifa, Jérôme

    2017-01-01

    Background The use of intra-cardiac electrograms to guide atrial fibrillation (AF) ablation has yielded conflicting results. We evaluated an electrogram marker of AF drivers: the clustering of electrograms exhibiting spatio-temporal dispersion — regardless of whether such electrograms were fractionated or not. Objective To evaluate the usefulness of spatio-temporal dispersion, a visually recognizable electric footprint of AF drivers, for the ablation of all forms of AF. Methods We prospectively enrolled 105 patients admitted for AF ablation. AF was sequentially mapped in both atria with a 20-pole PentaRay catheter. We tagged and ablated only regions displaying electrogram dispersion during AF. Results were compared to a validation set in which a conventional ablation approach was used (pulmonary vein isolation/stepwise approach). To establish the mechanism underlying spatio-temporal dispersion of AF electrograms, we conducted realistic numerical simulations of AF drivers in a 2-dimensional model and optical mapping of ovine atrial scar-related AF. Results Ablation at dispersion areas terminated AF in 95%. After ablation of 17±10% of the left atrial surface and 18 months of follow-up, the atrial arrhythmia recurrence rate was 15% after 1.4±0.5 procedure/patient vs 41% in the validation set after 1.5±0.5 procedure/patient (arrhythmia free-survival rates: 85% vs 59%, log rank P<0.001). In comparison with the validation set, radiofrequency times (49 ± 21 minutes vs 85 ± 34.5 minutes, p=0.001) and procedure times (168 ± 42 minutes vs. 230 ± 67 minutes, p<.0001) were shorter. In simulations and optical mapping experiments, virtual PentaRay recordings demonstrated that electrogram dispersion is mostly recorded in the vicinity of a driver. Conclusions The clustering of intra-cardiac electrograms exhibiting spatio-temporal dispersion is indicative of AF drivers. Their ablation allows for a non-extensive and patient-tailored approach to AF ablation. Clinical trial

  20. Treatment of Recurrent Nonparoxysmal Atrial Fibrillation Using Focal Impulse and Rotor Mapping (FIRM)-Guided Rotor Ablation: Early Recurrence and Long-Term Outcomes.

    PubMed

    Spitzer, Stefan Georg; Károlyi, László; Rämmler, Carola; Scharfe, Frank; Weinmann, Thomas; Zieschank, Mirko; Langbein, Anke

    2017-01-01

    A patient-tailored ablation approach focused on the elimination of both pulmonary vein triggers as well as substrate drivers may result in favorable outcomes in recurrent persistent AF patients. We evaluated the long-term outcomes of rotor ablation combined with conventional pulmonary vein isolation (PVI) in patients with recurrent nonparoxysmal AF. Fifty-eight consecutive patients underwent FIRM-guided rotor ablation followed by conventional PVI for the treatment of recurrent nonparoxysmal AF. A software algorithm was used to display rotational activity at rotor sites by creating propagation maps from unipolar electrograms recorded using a 64-electrode basket catheter. These rotor sites were targeted for ablation, followed by conventional PVI. All patients had nonparoxysmal AF (83% longstanding persistent) and a previously failed conventional ablation procedure. Stable rotors were identified in all patients (mean of 3.0 ± 1.6 per patient), with 55.2% having right atrial rotors and 96.6% left atrial rotors, respectively. Complications occurred in 5.2% of patients, none related to the FIRM procedure. The median follow-up was 12 months. At 6 and 12 months of follow-up, 73.2% and 76.9% of patients remained free from AF/AT, respectively. Excluding 2 patients who underwent a successful redo ablation procedure/electrical cardioversion, at 12 months of follow-up, 69.2% were free from any AF/AT and 73.1% were free from AF after a single FIRM-guided ablation procedure. A high degree of success was observed in this cohort of primarily longstanding persistent AF patients treated for recurrent AF with FIRM-guided rotor ablation. Prospective randomized controlled trials are needed. © 2016 Wiley Periodicals, Inc.

  1. Ablation of Persistent Atrial Fibrillation Targeting Low-Voltage Areas With Selective Activation Characteristics.

    PubMed

    Jadidi, Amir S; Lehrmann, Heiko; Keyl, Cornelius; Sorrel, Jérémie; Markstein, Viktor; Minners, Jan; Park, Chan-Il; Denis, Arnaud; Jaïs, Pierre; Hocini, Mélèze; Potocnik, Clemens; Allgeier, Juergen; Hochholzer, Willibald; Herrera-Sidloky, Claudia; Kim, Steve; Omri, Youssef El; Neumann, Franz-Josef; Weber, Reinhold; Haïssaguerre, Michel; Arentz, Thomas

    2016-03-01

    Complex-fractionated atrial electrograms and atrial fibrosis are associated with maintenance of persistent atrial fibrillation (AF). We hypothesized that pulmonary vein isolation (PVI) plus ablation of selective atrial low-voltage sites may be more successful than PVI only. A total of 85 consecutive patients with persistent AF underwent high-density atrial voltage mapping, PVI, and ablation at low-voltage areas (LVA < 0.5 mV in AF) associated with electric activity lasting > 70% of AF cycle length on a single electrode (fractionated activity) or multiple electrodes around the circumferential mapping catheter (rotational activity) or discrete rapid local activity (group I). The procedural end point was AF termination. Arrhythmia freedom was compared with a control group (66 patients) undergoing PVI only (group II). PVI alone was performed in 23 of 85 (27%) patients of group I with low amount (< 10% of left atrial surface area) of atrial low voltage. Selective atrial ablation in addition to PVI was performed in 62 patients with termination of AF in 45 (73%) after 11 ± 9 minutes radiofrequency delivery. AF-termination sites colocalized within LVA in 80% and at border zones in 20%. Single-procedural arrhythmia freedom at 13 months median follow-up was achieved in 59 of 85 (69%) patients in group I, which was significantly higher than the matched control group (31/66 [47%], P < 0.001). There was no significant difference in the success rate of patients in group I with a low amount of low voltage undergoing PVI only and patients requiring PVI+selective low-voltage ablation (P = 0.42). Ablation of sites with distinct activation characteristics within/at borderzones of LVA in addition to PVI is more effective than conventional PVI-only strategy for persistent AF. PVI only seems to be sufficient to treat patients with left atrial low voltage < 10%. © 2016 American Heart Association, Inc.

  2. Mapping of the left-sided phrenic nerve course in patients undergoing left atrial catheter ablations.

    PubMed

    Huemer, Martin; Wutzler, Alexander; Parwani, Abdul S; Attanasio, Philipp; Haverkamp, Wilhelm; Boldt, Leif-Hendrik

    2014-09-01

    Catheter ablation of atrial fibrillation has been associated with left-sided phrenic nerve palsy. Knowledge of the individual left phrenic nerve course therefore is essential to prevent nerve injury. The aim of this study was to test the feasibility of an intraprocedural pace mapping and reconstruction of the left phrenic nerve course and to characterize which anatomical areas are affected. In patients undergoing left atrial catheter ablation, a three-dimensional map of the left atrial anatomical structures was created. The left-sided phrenic nerve course was determined by high-output pace mapping and reconstructed in the map. In this study, 40 patients with atrial fibrillation or atrial tachycardias were included. Left phrenic nerve capture was observed in 23 (57.5%) patients. Phrenic nerve was captured in 22 (55%) patients inside the left atrial appendage, in 22 (55%) in distal parts, in 21 (53%) in medial parts, and in two (5%) in ostial parts of the appendage. In three (7.5%) patients, capture was found in the distal coronary sinus and in one (2.5%) patient in the left atrium near the left atrial appendage ostium. Ablation target was changed due to direct spatial relationship to the phrenic nerve in three (7.5%) patients. No phrenic nerve palsy was observed. Left-sided phrenic nerve capture was found inside and around the left atrial appendage in the majority of patients and additionally in the distal coronary sinus. Phrenic nerve mapping and reconstruction can easily be performed and should be considered prior catheter ablations in potential affected areas. ©2014 Wiley Periodicals, Inc.

  3. Radiofrequency catheter ablation versus balloon cryoablation of atrial fibrillation: markers of myocardial damage, inflammation, and thrombogenesis.

    PubMed

    Antolič, Bor; Pernat, Andrej; Cvijić, Marta; Žižek, David; Jan, Matevž; Šinkovec, Matjaž

    2016-07-01

    Evidence from animal and human studies suggests that cryoablation might be associated with a lesser inflammatory response and activation of coagulation compared with radiofrequency ablation. The study was aimed at comparing the effect of cryoballoon and radiofrequency catheter ablation of paroxysmal atrial fibrillation on markers of myocardial damage, inflammation, and activation of coagulation. Forty-one patients received either cryoballoon (n = 23) or radiofrequency (n = 18) ablation of atrial fibrillation. We measured troponin I, high-sensitivity CRP, and interleukin 6 at baseline from the cubital vein, and from the right and left atrium before and after ablation, and from the cubital vein the following day. Prothrombin fragments 1 + 2, soluble P‑selectin, and D‑dimer were measured before and after ablation from both atria. We observed higher troponin I release in the cryoballoon than in the radiofrequency group (7.01 mcg/l (interquartile range [IQR]: 5.30-9.09) vs 2.32 mcg/l (IQR: 1.45-2.98), p < 0.001). The levels of inflammatory markers (high-sensitivity CRP and interleukin 6) in the two groups were comparable, as were the levels of markers of coagulation activation. Procedure duration, fluoroscopy times, and mid-term success (23 months, IQR 7-32) of the two groups were also comparable. Cryoballoon ablation of atrial fibrillation causes more significant myocardial damage, that is, more extensive ablation lesions, compared with radiofrequency catheter ablation. However, no major differences between these two ablation techniques with regard to the inflammatory response and activation of the coagulation system were observed.

  4. Comparison of remote magnetic navigation ablation and manual ablation of idiopathic ventricular arrhythmia after failed manual ablation.

    PubMed

    Kawamura, Mitsuharu; Scheinman, Melvin M; Tseng, Zian H; Lee, Byron K; Marcus, Gregory M; Badhwar, Nitish

    2017-01-01

    Catheter ablation for idiopathic ventricular arrhythmia (VA) is effective and safe, but efficacy is frequently limited due to an epicardial origin and difficult anatomy. The remote magnetic navigation (RMN) catheter has a flexible catheter design allowing access to difficult anatomy. We describe the efficacy of the RMN for ablation of idiopathic VA after failed manual ablation. Among 235 patients with idiopathic VA referred for catheter ablation, we identified 51 patients who were referred for repeat ablation after a failed manual ablation. We analyzed the clinical characteristics, including the successful ablation site and findings at electrophysiology study, in repeat procedures conducted using RMN as compared with manual ablation. Among these patients, 22 (43 %) underwent repeat ablation with the RMN and 29 (57 %) underwent repeat ablation with a manual ablation. Overall, successful ablation rate was significantly higher using RMN as compared with manual ablation (91 vs. 69 %, P = 0.02). Fluoroscopy time in the RMN was 17 ± 12 min as compared with 43 ± 18 min in the manual ablation (P = 0.009). Successful ablation rate in the posterior right ventricular outflow tract (RVOT) plus posterior-tricuspid annulus was higher with RMN as compared with manual ablation (92 vs. 50 %, P = 0.03). Neither groups exhibited any major complications. The RMN is more effective in selected patients with recurrent idiopathic VA after failed manual ablation and is associated with less fluoroscopy time. The RMN catheters have a flexible design enabling them to access otherwise difficult anatomy including the posterior tricuspid annulus and posterior RVOT.

  5. Biophysics and pathology of catheter energy delivery systems.

    PubMed

    Nath, S; Haines, D E

    1995-01-01

    Catheter ablation has rapidly emerged as the treatment of choice for many symptomatic cardiac arrhythmias. The initial experience with catheter ablation used high-energy DC as the energy source. However, over the last several years radiofrequency (RF) catheter ablation has become the dominant mode of energy delivery. Currently, a major limitation of RF ablation is the small lesion size created by this technique that has reduced its success rate in ablation of larger arrhythmogenic substrates such as coronary artery disease-related ventricular tachycardia. Alternate energy sources such as microwave or ultrasound catheter ablation are being developed that have the potential for producing larger lesions than RF ablation. This review will discuss the biophysics and pathophysiology of the various energy modalities used in catheter ablation.

  6. Long-Term Outcome With Catheter Ablation of Ventricular Tachycardia in Patients With Arrhythmogenic Right Ventricular Cardiomyopathy.

    PubMed

    Santangeli, Pasquale; Zado, Erica S; Supple, Gregory E; Haqqani, Haris M; Garcia, Fermin C; Tschabrunn, Cory M; Callans, David J; Lin, David; Dixit, Sanjay; Hutchinson, Mathew D; Riley, Michael P; Marchlinski, Francis E

    2015-12-01

    Catheter ablation of ventricular tachycardia (VT) in arrhythmogenic right ventricular cardiomyopathy improves short-term VT-free survival. We sought to determine the long-term outcomes of VT control and need for antiarrhythmic drug therapy after endocardial (ENDO) and adjuvant epicardial (EPI) substrate modification in patients with arrhythmogenic right ventricular cardiomyopathy. We examined 62 consecutive patients with Task Force criteria for arrhythmogenic right ventricular cardiomyopathy referred for VT ablation with a minimum follow-up of 1 year. Catheter ablation was guided by activation/entrainment mapping for tolerated VT and pacemapping/targeting of abnormal substrate for unmappable VT. Adjuvant EPI ablation was performed when recurrent VT or persistent inducibility after ENDO-only ablation. Endocardial plus adjuvant EPI ablation was performed in 39 (63%) patients, including 13 who crossed over to ENDO-EPI after VT recurrence during follow-up, after ENDO-only ablation. Before ablation, 54 of 62 patients failed a mean of 2.4 antiarrhythmic drugs, including amiodarone in 29 (47%) patients. During follow-up of 56±44 months after the last ablation, VT-free survival was 71% with only a single VT episode in additional 9 patients (15%). At last follow-up, 39 (64%) patients were only on β-blockers or no treatment, 21 were on class 1 or 3 antiarrhythmic drugs (11 for atrial arrhythmias), and 2 were on amiodarone as a bridge to heart transplantation. The long-term outcome after ENDO and adjuvant EPI substrate ablation of VT in arrhythmogenic right ventricular cardiomyopathy is good. Most patients have complete VT control without amiodarone therapy and limited need for antiarrhythmic drugs. © 2015 American Heart Association, Inc.

  7. Remote magnetic navigation for catheter ablation of atrioventricular nodal reentrant tachycardia: a systematic review and meta-analysis.

    PubMed

    Shurrab, Mohammed; Danon, Asaf; Crystal, Alexander; Arouny, Banafsheh; Tiong, Irving; Lashevsky, Ilan; Newman, David; Crystal, Eugene

    2013-07-01

    Catheter ablation has become a well-established, first-line therapy for atrioventricular nodal reentrant tachycardia (AVNRT), the most common reentry supraventricular tachycardia in humans. Robotic systems are becoming increasingly common in both complex and simple ablation procedures with presumed potential improvements in procedural efficacy and safety. The authors of this article conducted a systematic review and meta-analysis on the effectiveness and safety of the magnetic navigation system (MNS) in comparison with conventional catheter navigation for AVNRT ablation. An electronic search was performed using Cochrane Central database, Medline, Embase and Web of Knowledge between 2002 and 2012. References were searched manually. Outcomes of interest were: acute and long-term success, complications, total procedure, ablation and fluoroscopic times. Continuous variables were reported as standardized difference in means (SDM); odds ratios (OR) were reported for dichotomous variables. Thirteen studies (seven of which were nonrandomized controlled, four were case series and two were randomized controlled studies) involving 679 adult patients were identified. Twelve studies were based on a single center and one study was multicentral. MNS was deployed in 339 patients. The follow-up period ranged between 75 and 180 days. Acute success and long-term freedom from arrhythmia were not significantly different between MNS and control groups (98 vs 98%, OR: 0.94 [95% CI: 0.21-4.1] and 97 vs 96%, OR: 1.18 [95% CI: 0.35-4.0], respectively). A shorter fluoroscopic time was achieved with MNS; however, this did not reach statistical significance (15 vs 19 min, SDM: -0.26 [95% CI: -0.64-0.12]). Longer total procedure but similar ablation times were noted with MNS (160 vs 148 min, SDM: 3.48 [95% CI: 0.75-6.21] and 4 vs 6 min, SDM: -0.83 [95% CI: -2.19-0.53], respectively). The overall complication rate was similar between both groups (2.7 vs 1.0%, OR: 1.28 [95%

  8. Reasons for recurrent ventricular tachycardia after catheter ablation of post-infarction ventricular tachycardia.

    PubMed

    Yokokawa, Miki; Desjardins, Benoit; Crawford, Thomas; Good, Eric; Morady, Fred; Bogun, Frank

    2013-01-08

    The purpose of this study was to assess the determinants of ventricular tachycardia (VT) recurrence in patients who underwent VT ablation for post-infarction VT. The factors that predict recurrence of VT after catheter ablation in patients with prior infarctions are not well described. Catheter ablation was performed in 98 consecutive patients (88 males [90%]; mean age 67 ± 10 years; ejection fraction 27 ± 13%) with post-infarction VT. Electrograms from the implantable cardioverter-defibrillator were analyzed, and VTs were classified as clinical, nonclinical, or new clinical. A total of 725 VTs were induced during the ablation procedure. All VTs were targeted. In 76 patients, 105 clinical VTs were inducible. Critical sites were identified with entrainment mapping and pace-mapping (≥10 of 12 matching leads) for 75 of 105 clinical VTs (71%) and for 278 of 620 nonclinical VTs (45%). Post-ablation, the clinical VT was not inducible in any patient, and all VTs were rendered noninducible in 63% of the patients. Over a mean follow-up period of 35 ± 23 months, 65 of 98 patients (66%) had no recurrent VTs and 33 (34%) had VT recurrence. A new VT occurred in 26 of 33 patients (79%), and a prior clinical VT recurred in 7 patients (21%). Patients with recurrent VT had a larger scar area as assessed by electroanatomic mapping compared with patients without recurrent VTs (93 ± 40 cm(2) vs. 69 ± 30 cm(2); p = 0.002). In patients with repeat procedures, the majority of inducible VTs for which a critical area could be identified were at a distance of 6 ± 3 mm to the prior ablation lesions. Patients with recurrent VTs have a larger scar as assessed by electroanatomic mapping. Most recurrent VTs were new, and the majority of these VTs were mapped to the vicinity of prior ablation lesions in patients with repeat procedures. Copyright © 2013 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  9. Box Isolation of Fibrotic Areas (BIFA): A Patient-Tailored Substrate Modification Approach for Ablation of Atrial Fibrillation.

    PubMed

    Kottkamp, Hans; Berg, Jan; Bender, Roderich; Rieger, Andreas; Schreiber, Doreen

    2016-01-01

    Catheter ablation strategies beyond pulmonary vein isolation (PVI) for treatment of atrial fibrillation (AF) are less well defined. Increasing clinical data indicate that atrial fibrosis is a critical common left atrial (LA) substrate in AF patients (pts). We applied a new substrate modification concept according to the individual fibrotic substrate as estimated from electroanatomic voltage mapping (EAVM) in 41 pts undergoing catheter ablation of AF. First, EAVM during sinus rhythm was done in redo cases of 10 pts with paroxysmal AF despite durable PVI. Confluent low-voltage areas (LVA) were found in all pts and were targeted with circumferential isolation, so-called box isolation of fibrotic areas (BIFA). This strategy led to stable sinus rhythm in 9/10 pts and was transferred prospectively to first procedures of 31 pts with nonparoxysmal AF. In 13 pts (42%), no LVA (<0.5 mV) were identified, and only PVI was performed. In 18 pts (58%), additional BIFA strategies were applied (posterior box in 5, anterior box in 7, posterior plus anterior box in 5, no box in 1 due to diffuse fibrosis). Mean follow-up was 12.5 ± 2.4 months. Single-procedure freedom from AF/atrial tachycardia was achieved in 72.2% of pts and in 83.3% of pts with 1.17 procedures/patient. In approximately 40% of pts with nonparoxysmal AF, no substantial LVA were identified, and PVI alone showed high success rate. In pts with paroxysmal AF despite durable PVI and in approximately 60% of pts with nonparoxysmal AF, individually localized LVA were identified and could be targeted successfully with the BIFA strategy. © 2015 Wiley Periodicals, Inc.

  10. Successful catheter ablation of a left anterior accessory pathway from the non-coronary cusp of the aortic valve.

    PubMed

    Laranjo, Sérgio; Oliveira, Mário; Trigo, Conceição

    2015-08-01

    Left anterior accessory pathways are considered to be rare findings. Catheter ablation of accessory pathways in this location remains a challenging target, and few reports about successful ablation of these accessory pathways are available. We describe our experience regarding a case of a manifest left anterior accessory pathway ablation using radiofrequency energy at the junction of the left coronary cusp with the non-coronary cusp.

  11. Materials for multifunctional balloon catheters with capabilities in cardiac electrophysiological mapping and ablation therapy

    NASA Astrophysics Data System (ADS)

    Kim, Dae-Hyeong; Lu, Nanshu; Ghaffari, Roozbeh; Kim, Yun-Soung; Lee, Stephen P.; Xu, Lizhi; Wu, Jian; Kim, Rak-Hwan; Song, Jizhou; Liu, Zhuangjian; Viventi, Jonathan; de Graff, Bassel; Elolampi, Brian; Mansour, Moussa; Slepian, Marvin J.; Hwang, Sukwon; Moss, Joshua D.; Won, Sang-Min; Huang, Younggang; Litt, Brian; Rogers, John A.

    2011-04-01

    Developing advanced surgical tools for minimally invasive procedures represents an activity of central importance to improving human health. A key challenge is in establishing biocompatible interfaces between the classes of semiconductor device and sensor technologies that might be most useful in this context and the soft, curvilinear surfaces of the body. This paper describes a solution based on materials that integrate directly with the thin elastic membranes of otherwise conventional balloon catheters, to provide diverse, multimodal functionality suitable for clinical use. As examples, we present sensors for measuring temperature, flow, tactile, optical and electrophysiological data, together with radiofrequency electrodes for controlled, local ablation of tissue. Use of such ‘instrumented’ balloon catheters in live animal models illustrates their operation, as well as their specific utility in cardiac ablation therapy. The same concepts can be applied to other substrates of interest, such as surgical gloves.

  12. Arrhythmia Termination Versus Elimination of Dormant Pulmonary Vein Conduction as a Procedural End Point of Catheter Ablation for Paroxysmal Atrial Fibrillation: A Prospective Randomized Trial.

    PubMed

    Theis, Cathrin; Konrad, Torsten; Mollnau, Hanke; Sonnenschein, Sebastian; Kämpfner, Denise; Potstawa, Maik; Ocete, Blanca Quesada; Bock, Karsten; Himmrich, Ewald; Münzel, Thomas; Rostock, Thomas

    2015-10-01

    Pulmonary vein isolation (PVI) is still associated with a substantial number of arrhythmia recurrences in paroxysmal atrial fibrillation (AF). This prospective, randomized study aimed to compare 2 different procedural strategies. A total of 152 patients undergoing de novo ablation for paroxysmal AF were randomized to 2 different treatment arms. The procedure in group A consisted of PVI exclusively. In this group, all isolated PVs were challenged with adenosine to reveal and ablate dormant conduction. In group B, PVI was performed with the patient either in spontaneous or in induced AF. If AF did not terminate with PVI, ablation was continued by targeting extra-PV AF sources with the desired procedural end point of termination to sinus rhythm. Primary study end point was freedom from arrhythmia during 1-year follow-up. In group A, adenosine provoked dormant conduction in 31 (41%) patients with a mean of 1.6±0.8 transiently recovered PVs per patient. Termination of AF during PVI was observed in 31 (65%) patients, whereas AF persisted afterward in 17 (35%) patients. AF termination occurred in 13 (76%) patients by AF source ablation. After 1-year follow-up, significantly more group B patients were free of arrhythmia recurrences (87 versus 68%; P=0.006). During redo ablation, the rate of PV reconduction did not differ between both groups (group A: 55% versus group B: 61%; P=0.25). Elimination of extra-PV AF sources after PVI is superior to sole PV isolation with the adjunct of abolishing potential dormant conduction. URL: http://www.clinicaltrials.gov. Unique identifier: NCT02238392. © 2015 The Authors.

  13. Remote magnetic navigation in atrial fibrillation.

    PubMed

    Szili-Torok, Tamas; Akca, Ferdi

    2012-05-01

    Atrial fibrillation (AF) is of profound public health importance and is largely a disease of aging and is responsible for increased morbidity- and mortality-related healthcare expenditures. Catheter ablation to isolate the pulmonary veins has become the therapy of choice for treatment of drug-refractory AF. Procedures can be very challenging and multiple difficulties must be overcome in order to achieve a successful outcome. The magnetic navigation system (MNS) has advantages in catheter maneuverability, stability and reproducibility. Due to the catheter design safety and efficacy of AF, ablation has increased. New developments are being made to allow fully remote ablation procedures in combination with the MNS. However, new technologies are still necessary to improve MNS ablation for AF.

  14. Visualizing intramyocardial steam formation with a radiofrequency ablation catheter incorporating near-field ultrasound.

    PubMed

    Wright, Matthew; Harks, Erik; Deladi, Szabolcs; Fokkenrood, Steven; Zuo, Fei; Van Dusschoten, Anneke; Kolen, Alexander F; Belt, Harm; Sacher, Frederic; Hocini, Mélèze; Haïssaguerre, Michel; Jaïs, Pierre

    2013-12-01

    Steam pops are a risk of irrigated RF ablation even when limiting power delivery. There is currently no way to predict gas formation during ablation. It would be useful to visualize intramyocardial gas formation prior to a steam pop occurring using near-field ultrasound integrated into a RF ablation catheter. In an in vivo open-chest ovine model (n = 9), 86 lesions were delivered to the epicardial surface of the ventricles. Energy was delivered for 15-60 seconds, to achieve lesions with and without steam pops, based on modeling data. The ultrasound image was compared to a digital audio recording from within the pericardium by a blinded observer. Of 86 lesions, 28 resulted in an audible steam pop. For lesions that resulted in a steam pop compared to those that did not (n = 58), the mean power delivered was 8.0 ± 1.8 W versus 6.7 ± 2.0 W, P = 0.006. A change in US contrast due to gas formation in the tissue occurred in all lesions that resulted in a steam pop. In 4 ablations, a similar change in US contrast was observed in the tissue and RF delivery was stopped; in these cases, no pop occurred. The mean depth of gas formation was 0.9 ± 0.8 mm, which correlated with maximal temperature predicted by modeling. Changes in US contrast occurred 7.6 ± 7.2 seconds before the impedance rise and 7.9 ± 6.2 seconds (0.1-17.0) before an audible pop. Integrated US in an RF ablation catheter is able to visualize gas formation intramyocardially several seconds prior to a steam pop occurring. This technology may help prevent complications arising from steam pops. © 2013 Wiley Periodicals, Inc.

  15. Value of local electrogram characteristics predicting successful catheter ablation of left-versus right-sided accessory atrioventricular pathways by radiofrequency current.

    PubMed

    Lin, J L; Schie, J T; Tseng, C D; Chen, W J; Cheng, T F; Tsou, S S; Chen, J J; Tseng, Y Z; Lien, W P

    1995-01-01

    Despite similar guidance by local electrogram criteria, catheter ablation of right-sided accessory atrioventricular (AV) pathways by radiofrequency current has been less effective than that of left-sided ones. In order to elucidate the possible diversities in local electrosignal criteria, we systematically analyzed the morphological and timing characteristics of 215 bipolar local electrograms from catheter ablation sites of 65 left-sided accessory AV pathways and of 356 from those of 37 right-sided ones in 92 consecutive patients with Wolff-Parkinson-White syndrome or AV reentrant tachycardia incorporating concealed accessory AV pathways. After stepwise multivariate analysis, we selected the presence of a possible accessory pathway potential, local ventricular activation preceding QRS complex for 20 ms or more during ventricular insertion mapping, and the local retrograde ventriculoatrial (VA) continuity, local retrograde VA interval < or = 50 ms, electrogram stability (left-sided targets only), retrograde accessory pathway potential (right-sided targets only) during atrial insertion mapping, as independent local electrogram predictors for successful ablation of left- and right-sided accessory AV pathways. Combination of all local electrogram predictors could have moderate chance of success (80 and 51%) for the ventricular and atrial insertion ablation of left-sided accessory AV pathways, but only low probability of success (40% in ventricular insertion ablation) or very low sensitivity (12.5% in atrial insertion ablation) for right-sided ones. In conclusion, with the present approach, successful catheter ablation of right-sided accessory AV pathways, compared to left-sided ones, still necessitate a breakthrough in the precision mapping and the efficiency of energy delivery.

  16. Pulmonary Vein Isolation Alone Versus Additional Linear Ablation in Patients With Persistent Atrial Fibrillation Converted to Paroxysmal Type With Antiarrhythmic Drug Therapy: A Multicenter, Prospective, Randomized Study.

    PubMed

    Yu, Hee Tae; Shim, Jaemin; Park, Junbeom; Kim, In-Soo; Kim, Tae-Hoon; Uhm, Jae-Sun; Joung, Boyoung; Lee, Moon-Hyoung; Kim, Young-Hoon; Pak, Hui-Nam

    2017-06-01

    Atrial fibrillation (AF) type can vary depending on condition and timing, and some patients who initially present with persistent AF may be changed to paroxysmal AF after antiarrhythmic drug medication and cardioversion. We investigated whether circumferential pulmonary vein isolation (CPVI) alone is an effective rhythm control strategy in patients with persistent AF to paroxysmal AF. We enrolled 113 patients with persistent AF to paroxysmal AF (male 75%, 60.4±10.1 years old) who underwent catheter ablation for nonvalvular AF at 3 tertiary hospitals. The participants were randomly assigned to 2 groups: CPVI alone (n=59) or CPVI plus linear ablation (CPVI+Line; posterior box+anterior line, n=54). Compared with the CPVI+Line, CPVI alone required shorter procedure (187.2±58.0 versus 211.2±63.9 min; P =0.043) and ablation times (4922.1±1110.5 versus 6205.7±1425.2 s; P <0.001) without difference in procedure-related major complication (3% versus 2%; P =0.611). Antiarrhythmic drug utility rates after ablation were not different between the 2 groups (22% versus 30%; P =0.356). Overall, AF-free survival (log-rank; P =0.206) and AF and antiarrhythmic drug-free survival (log-rank; P =0.321) were not different between groups. CPVI alone is an effective rhythm control strategy with a shorter procedure time in persistent AF patients converted to paroxysmal AF compared with CPVI with linear ablation. URL: https://www.clinicaltrials.gov. Unique identifier: NCT02176616. © 2017 American Heart Association, Inc.

  17. Remotely controlled steerable sheath improves result and procedural parameters of atrial fibrillation ablation with magnetic navigation.

    PubMed

    Errahmouni, Abdelkarim; Latcu, Decebal Gabriel; Bun, Sok-Sithikun; Rijo, Nicolas; Dugourd, Céline; Saoudi, Nadir

    2015-07-01

    The magnetic navigation (MN) system may be coupled with a new advancement system that fully controls both the catheter and a robotic deflectable sheath (RSh) or with a fixed-curve sheath and a catheter-only advancement system (CAS). We aimed to compare these approaches for atrial fibrillation (AF) ablation. Atrial fibrillation ablation patients (45, 23 paroxysmal and 22 persistent) performed with MN-RSh (RSh group) were compared with a control group (37, 18 paroxysmal and19 persistent) performed with MN-CAS (CAS group). Setup duration was measured from the procedure's start to operator transfer to control room. Ablation step duration was defined as the time from the beginning of the first radiofrequency (RF) pulse to the end of the last one and was separately acquired for the left and the right pulmonary vein (PV) pairs. Clinical characteristics, left atrial size, and AF-type distribution were similar between the groups. Setup duration as well as mapping times was also similar. Ablation step duration for the left PVs was similar, but was shorter for the right PVs in RSh group (46 ± 9 vs. 63 ± 12 min, P < 0.0001). Radiofrequency delivery time (34 ± 9 vs. 40 ± 11 min, P = 0.007) and procedure duration (227 ± 36 vs. 254 ± 62 min, P = 0.01) were shorter in RSh group. No complication occurred in RSh group. During follow-up, there were five recurrences (11%) in RSh group and 11 (29%) in CAS group (P = 0.027). The use of the RSh for AF ablation with MN is safe and improves outcome. Right PV isolation is faster, RF delivery time and procedure time are reduced. © The Author 2015. Published by Oxford University Press on behalf of the European Society of Cardiology.

  18. Remotely controlled steerable sheath improves result and procedural parameters of atrial fibrillation ablation with magnetic navigation

    PubMed Central

    Errahmouni, Abdelkarim; Latcu, Decebal Gabriel; Bun, Sok-Sithikun; Rijo, Nicolas; Dugourd, Céline; Saoudi, Nadir

    2015-01-01

    Aims The magnetic navigation (MN) system may be coupled with a new advancement system that fully controls both the catheter and a robotic deflectable sheath (RSh) or with a fixed-curve sheath and a catheter-only advancement system (CAS). We aimed to compare these approaches for atrial fibrillation (AF) ablation. Methods and results Atrial fibrillation ablation patients (45, 23 paroxysmal and 22 persistent) performed with MN–RSh (RSh group) were compared with a control group (37, 18 paroxysmal and19 persistent) performed with MN–CAS (CAS group). Setup duration was measured from the procedure's start to operator transfer to control room. Ablation step duration was defined as the time from the beginning of the first radiofrequency (RF) pulse to the end of the last one and was separately acquired for the left and the right pulmonary vein (PV) pairs. Clinical characteristics, left atrial size, and AF-type distribution were similar between the groups. Setup duration as well as mapping times was also similar. Ablation step duration for the left PVs was similar, but was shorter for the right PVs in RSh group (46 ± 9 vs. 63 ± 12 min, P < 0.0001). Radiofrequency delivery time (34 ± 9 vs. 40 ± 11 min, P = 0.007) and procedure duration (227 ± 36 vs. 254 ± 62 min, P = 0.01) were shorter in RSh group. No complication occurred in RSh group. During follow-up, there were five recurrences (11%) in RSh group and 11 (29%) in CAS group (P = 0.027). Conclusion The use of the RSh for AF ablation with MN is safe and improves outcome. Right PV isolation is faster, RF delivery time and procedure time are reduced. PMID:25662989

  19. Does a patent foramen ovale matter when using a remote-controlled magnetic system for pulmonary vein isolation?

    PubMed

    Gate-Martinet, Alexie; Da Costa, Antoine; Romeyer-Bouchard, Cécile; Bisch, Laurence; Levallois, Marie; Isaaz, Karl

    2014-02-01

    Pulmonary vein isolation (PVI) takes longer when using a patent foramen ovale (PFO) compared with a transseptal puncture in paroxysmal atrial fibrillation (AF) with manual catheter ablation. To our knowledge, no data exist concerning the impact of a PFO on AF ablation procedure variables when using a remote magnetic navigation (RMN) system. To assess the impact of a PFO when using an RMN system in patients requiring AF ablation. Between December 2011 and December 2012, catheter ablation was performed remotely using the CARTO(®) 3 system in 167 consecutive patients who underwent PVI for symptomatic drug-refractory AF. The radiofrequency generator was set to a fixed power ≤ 35 W. The primary endpoint was wide-area circumferential PVI confirmed by spiral catheter recording during ablation for all patients and including additional lesion lines (left atrial roof) or complex fractionated atrial electrograms for persistent AF. Secondary endpoints included procedural data. Mean age 58±10 years; 18% women; 107 (64%) patients with symptomatic paroxysmal AF; 60 (36%) with persistent AF; CHA2DS2-VASc score 1.2 ± 1. The PFO presence was evidenced in 49/167 (29.3%) patients during the procedure but in only 26/167 (16%) by transoesophageal echocardiography. Median procedure time 2.5 ± 1 hours; median total X-ray exposure time 14 ± 7 minutes; transseptal puncture and catheter positioning time 7.5 ± 5 minutes; left atrium electroanatomical reconstruction time 3 ± 2.3 minutes; catheter ablation time 3 ± 3 minutes. No procedure time or X-ray exposure differences were observed between patients with or without a PFO during magnetic navigation catheter ablation. X-ray exposure time was significantly reduced using a PFO compared with double transseptal puncture access. A PFO does not affect magnetic navigation during AF ablation; procedure times and X-ray exposure were similar. Septal catheter probing is mandatory to limit X-ray exposure and prevent potential complications

  20. Safety and feasibility of single-catheter ablation using remote magnetic navigation for treatment of slow-fast atrioventricular nodal reentrant tachycardia compared to conventional ablation strategies.

    PubMed

    Akca, Ferdi; Schwagten, Bruno; Theuns, Dominic A J; Takens, Marieke; Musters, Paul; Szili-Torok, Tamas

    2013-12-01

    Ablation of atrioventricular nodal re-entrant tachycardia (AVNRT) is a highly effective procedure both with radiofrequency (RF) and cryoenergy (CE). Conventionally, it requires several diagnostic catheters and hospital admission. This study assessed the safety and efficacy of a highly simplified approach using the magnetic navigation system (MNS) compared to CE and manual RF ablation (MAN). In the MNS group a single magnetic-guided quadripolar catheter was inserted through the internal jugular vein to perform ablation. In the CE group cryomapping preceded ablation and for MAN procedures conventional ablation was performed. The following parameters were analysed: success- and recurrence rate, procedure-, fluoroscopy- and total application time. In total 69 eligible patients were treated with MNS (n = 26), CE (n = 25) and MAN (n = 16). The success rates were 100%, 100% and 94%, respectively (p = ns). The mean procedural time was 83 +/- 25 min for MNS, 117 +/- 47 min for CE and 117 +/- 55 min for MAN (P < 0.01). Total radiation time was significantly lower for MNS [0.0 min (IQR 0.0-0.0)] compared to CE [15.1 min (IQR 9.1-23.8), P < 0.001] and MAN [17.5 min (IQR 7.0-31.3), P < 0.001]. The total application time was comparable for both RF groups: 357 +/- 315 s (MNS) vs 204 +/- 177 s (MAN) (P = 0.14). No major adverse events occurred. After 3 months follow-up similar PR intervals were recorded for all patients. During a follow-up of 26 +/- 5 months recurrence rates were 3.8%, 4.0% and 6.3%, respectively, for each group. The MNS-guided single-catheter approach is a feasible and safe technique for the treatment of patients with typical AVNRT.

  1. Robotically assisted ablation produces more rapid and greater signal attenuation than manual ablation.

    PubMed

    Koa-Wing, Michael; Kojodjojo, Pipin; Malcolme-Lawes, Louisa C; Salukhe, Tushar V; Linton, Nick W F; Grogan, Aaron P; Bergman, Dale; Lim, Phang Boon; Whinnett, Zachary I; McCarthy, Karen; Ho, Siew Yen; O'Neill, Mark D; Peters, Nicholas S; Davies, D Wyn; Kanagaratnam, Prapa

    2009-12-01

    Robotic remote catheter ablation potentially provides improved catheter-tip stability, which should improve the efficiency of radiofrequency energy delivery. Percentage reduction in electrogram peak-to-peak voltage has been used as a measure of effectiveness of ablation. We tested the hypothesis that improved catheter-tip stability of robotic ablation can diminish signals to a greater degree than manual ablation. In vivo NavX maps of 7 pig atria were constructed. Separate lines of ablation were performed robotically and manually, recording pre- and postablation peak-to-peak voltages at 10, 20, 30, and 60 seconds and calculating signal amplitude reduction. Catheter ablation settings were constant (25W, 50 degrees , 17 mL/min, 20-30 g catheter tip pressure). The pigs were sacrificed and ablation lesions correlated with NavX maps. Robotic ablation reduced signal amplitude to a greater degree than manual ablation (49 +/- 2.6% vs 29 +/- 4.5% signal reduction after 1 minute [P = 0.0002]). The mean energy delivered (223 +/- 184 J vs 231 +/- 190 J, P = 0.42), power (19 +/- 3.5 W vs 19 +/- 4 W, P = 0.84), and duration of ablation (15 +/- 9 seconds vs 15 +/- 9 seconds, P = 0.89) was the same for manual and robotic. The mean peak catheter-tip temperature was higher for robotic (45 +/- 5 degrees C vs 42 +/- 3 degrees C [P < 0.0001]). The incidence of >50% signal reduction was greater for robotic (37%) than manual (21%) ablation (P = 0.0001). Robotically assisted ablation appears to be more effective than manual ablation at signal amplitude reduction, therefore may be expected to produce improved clinical outcomes.

  2. Magnetic navigation and catheter ablation of right atrial ectopic tachycardia in the presence of a hemi-azygos continuation: a magnetic navigation case using 3D electroanatomical mapping.

    PubMed

    Ernst, Sabine; Chun, Julian K R; Koektuerk, Buelent; Kuck, Karl-Heinz

    2009-01-01

    We report on a 63-year-old female patient in whom an electrophysiologic study discovered a hemi-azygos continuation. Using the magnetic navigation system, remote-controlled ablation was performed in conjunction with the 3D electroanatomical mapping system. Failing the attempt to advance a diagnostic catheter from the femoral vein, a diagnostic catheter was advanced via the left subclavian vein into the coronary sinus. The soft magnetic catheter was positioned in the right atrium via the hemi-azygos vein, and 3D mapping demonstrated an ectopic atrial tachycardia. Successful ablation was performed entirely remote controlled. Fluoroscopy time was only 7.1 minutes, of which 45 seconds were required during remote navigation. Remote-controlled catheter ablation using magnetic navigation in conjunction with the electroanatomical mapping system proved to be a valuable tool to perform successful ablation in the presence of a hemi-azygos continuation.

  3. Successful catheter ablation of ventricular premature complexes from the right atrial side of the atrioventricular septum with good contact force.

    PubMed

    Arai, Marina; Fukamizu, Seiji; Kawamura, Iwanari; Miyazawa, Satoshi; Hojo, Rintaro; Sakurada, Harumizu; Hiraoka, Masayasu

    2018-04-01

    The acquisition of good contact force for radiofrequency catheter ablation of ventricular premature complexes (VPCs) originating from the basal septum of the left ventricle (LV) is often difficult. We describe a case of VPCs originating from the basal septum of the LV, which were successfully eliminated by applying radiofrequency at the right atrium (RA) side of the atrioventricular septum (AVS) without causing any significant impairment of atrioventricular conduction because the ablation catheter could obtain better contact force through the RA approach. Moreover, intracardiac echocardiography (ICE) and RA angiography effectively demonstrated the AVS.

  4. Magnetic versus manual catheter navigation for mapping and ablation of right ventricular outflow tract ventricular arrhythmias: a randomized controlled study.

    PubMed

    Zhang, Fengxiang; Yang, Bing; Chen, Hongwu; Ju, Weizhu; Kojodjojo, Pipin; Cao, Kejiang; Chen, Minglong

    2013-08-01

    No randomized controlled study has prospectively compared the performance and clinical outcomes of remote magnetic control (RMC) vs manual catheter control (MCC) during ablation of right ventricular outflow tract (RVOT) ventricular premature complexes (VPC) or ventricular tachycardia (VT). The purpose of this study was to prospectively evaluate the efficacy and safety of using either RMC vs MCC for mapping and ablation of RVOT VPC/VT. Thirty consecutive patients with idiopathic RVOT VPC/VT were referred for catheter ablation and randomized into either the RMC or MCC group. A noncontact mapping system was deployed in the RVOT to identify origins of VPC/VT. Conventional activation and pace-mapping was performed to guide ablation. If ablation performed using 1 mode of catheter control was acutely unsuccessful, the patient crossed over to the other group. The primary endpoints were patients' and physicians' fluoroscopic exposure and times. Mean procedural times were similar between RMC and MCC groups. The fluoroscopic exposure and times for both patients and physicians were much lower in the RMC group than in the MCC group. Ablation was acutely successful in 14 of 15 patients in the MCC group and 10 of 15 in the RMC group. Following crossover, acute success was achieved in all patients. No major complications occurred in either group. During 22 months of follow-up, RVOT VPC recurred in 2 RMC patients. RMC navigation significantly reduces patients' and physicians' fluoroscopic times by 50.5% and 68.6%, respectively, when used in conjunction with a noncontact mapping system to guide ablation of RVOT VPC/VT. Copyright © 2013 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  5. Catheter ablation versus medical therapy for patients with persistent atrial fibrillation: a systematic review and meta-analysis of evidence from randomized controlled trials.

    PubMed

    Chen, Chen; Zhou, Xinbin; Zhu, Min; Chen, Shenjie; Chen, Jie; Cai, Hongwen; Dai, Jin; Xu, Xiaoming; Mao, Wei

    2018-06-01

    The superiority of catheter ablation (CA) for persistent (and long-standing persistent) atrial fibrillation (AF) is currently not well defined. We performed a meta-analysis of randomized controlled trials (RCTs) to assess the clinical outcomes of CA compared with medical therapy in persistent AF patients. We systematically searched PubMed, EMBASE, the Cochrane Library, and clinicaltrials.gov for RCTs comparing CA with medical therapy in patients with persistent AF. For CA vs medical rhythm control, the primary outcome was freedom from atrial arrhythmia. For CA vs medical rate control, the primary outcome was the change in the left ventricular ejection fraction (LVEF). Eight studies with a total of 809 patients were included in the final analysis. Compared with medical rhythm control, CA was superior in achieving freedom from atrial arrhythmia (RR 2.08, 95% CI [1.67, 2.58]; P < 0.00001). Similar result was found in CA arm without antiarrhythmic drug use after operation (RR 1.82, 95%CI [1.33, 2.49]; P = 0.0002). CA was also superior in reducing the probability of cardioversion (RR 0.59, 95%CI [0.46, 0.76]; P < 0.0001) and hospitalization (RR 0.54, 95%CI [0.39, 0.74]; P = 0.0002). Compared with the medical rate control in persistent AF patients with heart failure (HF), CA significantly improved the LVEF (MD 7.72, 95%CI [4.78, 10.67]; P < 0.00001) and reduced Minnesota Living with Heart Failure Questionnaire scores (MD 11.1395% CI [2.52-19.75]; P = 0.01). CA appeared to be superior to medical therapy in persistent AF patients and might be considered as a first-line therapy for some persistent AF patients especially for those with HF.

  6. Results of Cryoenergy and Radiofrequency-Based Catheter Ablation for Treating Ventricular Arrhythmias Arising From the Papillary Muscles of the Left Ventricle, Guided by Intracardiac Echocardiography and Image Integration.

    PubMed

    Rivera, Santiago; Ricapito, Maria de la Paz; Tomas, Leandro; Parodi, Josefina; Bardera Molina, Guillermo; Banega, Rodrigo; Bueti, Pablo; Orosco, Agustin; Reinoso, Marcelo; Caro, Milagros; Belardi, Diego; Albina, Gaston; Giniger, Alberto; Scazzuso, Fernando

    2016-04-01

    Catheter radiofrequency ablation of ventricular arrhythmias (VAs) arising from the left ventricle's papillary muscles has been associated with inconsistent results. The use of cryoenergy versus radiofrequency has not been compared yet. This study compares outcomes and complications of catheter ablation of VA from the papillary muscles of the left ventricle with either cryoenergy or radiofrequency. Twenty-one patients (40±12 years old; 47% males; median ejection fraction 59±7.3%) with drug refractory premature ventricular contractions or ventricular tachycardia underwent catheter cryoablation or radiofrequency ablation. VAs were localized using 3-dimensional mapping, multidetector computed tomography, and intracardiac echocardiography, with arrhythmia foci being mapped at either the anterolateral papillary muscle or posteromedial papillary muscles of the left ventricle. Focal ablation was performed using an 8-mm cryoablation catheter or a 4-mm open-irrigated radiofrequency catheter, via transmitral approach. Acute success rate was 100% for cryoenergy (n=12) and 78% for radiofrequency (n=9; P=0.08). Catheter stability was achieved in all patients (100%) treated with cryoenergy, and only in 2 (25%) patients treated with radiofrequency (P=0.001). Incidence of multiple VA morphologies was observed in 7 patients treated with radiofrequency (77.7%), whereas none was observed in those treated with cryoenergy (P=0.001). VA recurrence at 6 months follow-up was 0% for cryoablation and 44% for radiofrequency (P=0.03). Cryoablation was associated with higher success rates and lower recurrence rates than radiofrequency catheter ablation, better catheter stability, and lesser incidence of polymorphic arrhythmias. © 2016 American Heart Association, Inc.

  7. Atrial fibrillation ablation using remote magnetic navigation and the risk of atrial-esophageal fistula: international multicenter experience.

    PubMed

    Danon, Asaf; Shurrab, Mohammed; Nair, Krishnakumar Mohanan; Latcu, Decebal Gabriel; Arruda, Mauricio S; Chen, Xu; Szili-Torok, Tamas; Rossvol, Ole; Wissner, Eric E; Lashevsky, Ilan; Crystal, Eugene

    2015-08-01

    Remote magnetic navigation (RMN) has been used in various electrophysiological procedures, including atrial fibrillation (AF) ablation. Atrial-esophageal fistula (AEF) is one of most disastrous complications of AF ablation. We aimed to evaluate the incidence of AEF during AF ablation using RMN in comparison to manual ablation. We conducted the first international survey among RMN operators for assessment of the prevalence of AEF and procedural parameters affecting the risk. Data from parallel survey of AEF among Canadian interventional electrophysiologists (CIE) using only manual catheters served as control. Fifteen RMN operators (who performed 3637 procedures) and 25 manual CIE operators (7016 procedures) responded to the survey. RMN operators were more experienced than CIE operators (16.3 ± 8.3 vs. 9.2 ± 5.4 practice years in electrophysiology, p = 0.007). The maximal energy output in the posterior wall was higher in the operator using RMN (33 ± 5 vs. 28.6 ± 4.9 W; p = 0.02). Other parameters including use of preprocedural images, irrigated catheter, pump flow rate, esophageal temperature monitoring, intracardiac echocardiography (ICE), and general anesthesia were similar. CIE operators administered proton-pump inhibitors postoperatively significantly more than RMN operators (76 vs. 35%, p = 0.01). AEF was reported in 5 of the 7016 patients in the control group (0.07%) but in none of the RMN group (p = 0.11). AEF is a rare complication and its evaluation necessitates large-scale studies. Although no AEF case with RMN was reported in this large study or previously on the literature, the rarity of this complication prevents firm conclusion about the risk.

  8. Improvement in quality of life after catheter ablation for paroxysmal versus long-standing persistent atrial fibrillation: a prospective study with 3-year follow-up.

    PubMed

    Bulková, Veronika; Fiala, Martin; Havránek, Stěpán; Simek, Jan; Skňouřil, Libor; Januška, Jaroslav; Spinar, Jindřich; Wichterle, Dan

    2014-07-18

    Changes in quality of life (QoL) after catheter ablation for long-standing persistent atrial fibrillation (LSPAF) are not well described. We sought to compare QoL improvement after catheter ablation of paroxysmal atrial fibrillation (PAF) versus that after LSPAF. A total of 261 PAF and 126 LSPAF ablation recipients were prospectively followed for arrhythmia recurrence, QoL, hospital stay, and sick leave. In PAF versus LSPAF groups, 1.3±0.6 versus 1.6±0.7 procedures were performed per patient (P<0.00001) during a 3-year follow-up. Good arrhythmia control was achieved in 86% versus 87% of patients (P=0.69) and in 69% versus 69% of patients not receiving antiarrhythmic drugs (P=0.99). The baseline QoL was better in the PAF than in the LSPAF group (European Quality of Life Group instrument self-report questionnaire visual analog scale: 66.4±14.2 versus 61.0±14.2, P=0.0005; European Quality of Life Group 3-level, 5-dimensional descriptive system: 71.4±9.2 versus 67.7±13.8, P=0.002). Postablation 3-year increase in QoL was significant in both groups (all P<0.00001) and significantly lower in PAF versus LSPAF patients (visual analog scale: +5.0±14.5 versus +10.2±12.8, P=0.001; descriptive system: +5.9±14.3 versus +9.3±13.9, P=0.03). In multivariate analysis, LSPAF, less advanced age, shorter history of AF and good arrhythmia control were consistently associated with postablation 3-year improvement in QoL. Days of hospital stay for cardiovascular reasons and days on sick leave per patient/year were significantly reduced in both groups. Patients with LSPAF had worse baseline QoL. The magnitude of QoL improvement after ablation of LSPAF was significantly greater compared with after ablation of PAF, particularly when good arrhythmia control was achieved without the use of antiarrhythmic drugs. © 2014 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley Blackwell.

  9. Electrophysiology testing and catheter ablation are helpful when evaluating asymptomatic patients with Wolff-Parkinson-White pattern: the pro perspective.

    PubMed

    Pappone, Carlo; Santinelli, Vincenzo

    2015-09-01

    Important advances in the natural history and diagnosis of, and therapy for, asymptomatic Wolff-Parkinson-White (WPW) syndrome have been made in the last decade by our group. These data have necessitated revisiting current practice guidelines to decide on the optimal management of the asymptomatic WPW population. There has also been an emphasis on identifying initially asymptomatic individuals who are at risk by nationwide screening programs using the electrocardiogram for prophylactic catheter ablation to prevent the lifetime risk of sudden cardiac death, particularly in young asymptomatic people, because only a subgroup of them is at high risk, requiring early catheter ablation. Copyright © 2015 Elsevier Inc. All rights reserved.

  10. Isolated Disruption of the Right Coronary Artery Following a Steam Pop during Cavotricuspid Linear Ablation with a Contact Force Catheter.

    PubMed

    Brunelli, Michele; Frommhold, Markus; Back, Dieter; Mierzwa, Marco; Lauer, Bernard; Geller, J Christoph

    2016-07-01

    A 70-year-old woman with persistent atrial fibrillation underwent pulmonary vein isolation and linear ablation with a contact sensor catheter. During cavotricuspid isthmus ablation, a steam pop resulted in cardiac tamponade, and the patient developed severe hypotension despite successful pericardial puncture and minimal residual pericardial effusion. Right coronary artery angiography revealed extravasal contrast medium accumulation posterior of the Crux Cordis. Emergent cardiac surgery confirmed isolated disruption of the artery in the absence of additional heart perforation. Although contact sensor catheters may reduce complications, steam pops can still occur and result in dramatic complications. © 2016 Wiley Periodicals, Inc.

  11. Epicardial phrenic nerve displacement during catheter ablation of atrial and ventricular arrhythmias: procedural experience and outcomes.

    PubMed

    Kumar, Saurabh; Barbhaiya, Chirag R; Baldinger, Samuel H; Koplan, Bruce A; Maytin, Melanie; Epstein, Laurence M; John, Roy M; Michaud, Gregory F; Tedrow, Usha B; Stevenson, William G

    2015-08-01

    Arrhythmia origin in close proximity to the phrenic nerve (PN) can hinder successful catheter ablation. We describe our approach with epicardial PN displacement in such instances. PN displacement via percutaneous pericardial access was attempted in 13 patients (age 49±16 years, 9 females) with either atrial tachycardia (6 patients) or atrial fibrillation triggered from a superior vena cava focus (1 patient) adjacent to the right PN or epicardial ventricular tachycardia origin adjacent to the left PN (6 patients). An epicardially placed steerable sheath/4 mm-catheter combination (5 patients) or a vascular or an esophageal balloon (8 patients) was ultimately successful. Balloon placement was often difficult requiring manipulation via a steerable sheath. In 2 ventricular tachycardia cases, absence of PN capture was achieved only once the balloon was directly over the ablation catheter. In 3 atrial tachycardia patients, PN displacement was not possible with a balloon; however, a steerable sheath/catheter combination was ultimately successful. PN displacement allowed acute abolishment of all targeted arrhythmias. No PN injury occurred acutely or in follow up. Two patients developed acute complications (pleuro-pericardial fistula 1 and pericardial bleeding 1). Survival free of target arrhythmia was achieved in all atrial tachycardia patients; however, a nontargeted ventricular tachycardia recurred in 1 patient at a median of 13 months' follow up. Arrhythmias originating in close proximity to the PN can be targeted successfully with PN displacement with an epicardially placed steerable sheath/catheter combination, or balloon, but this strategy can be difficult to implement. Better tools for phrenic nerve protection are desirable. © 2015 American Heart Association, Inc.

  12. Outcomes after cryoballoon or radiofrequency ablation for persistent atrial fibrillation: a multicentric propensity-score matched study.

    PubMed

    Boveda, Serge; Providência, Rui; Defaye, Pascal; Pavin, Dominique; Cebron, Jean-Pierre; Anselme, Frederic; Halimi, Franck; Khoueiry, Ziad; Combes, Nicolas; Combes, Stephane; Jacob, Sophie; Albenque, Jean-Paul; Sousa, Pedro

    2016-11-01

    Recent data show no benefit of additional ablation beyond pulmonary vein isolation (PVI) in persistent atrial fibrillation (AF). Evidence suggests that radiofrequency energy (RF) and cryoballoon (CRYO) have comparable efficacy for PVI. We aimed to assess the outcomes after a single catheter ablation procedure, comparing PVI using CRYO vs. RF ablation for PVI plus additional ablation in a cohort of patients with persistent AF. In this prospective multicenter propensity score-matched comparison, 59 consecutive patients undergoing CRYO ablation of persistent AF were matched to 59 patients treated with RF from November 2010 to June 2012. During a mean follow-up of 15.6 ± 11.5 months, 43.2 % of patients presented atrial arrhythmia relapse after a blanking period of 3 months, which was comparable between the two groups (40.7 % in CRYO vs. 45.8 % in RF, Log rank P = 0.14; HR = 0.67, 95 %CI 0.38-1.16, P = 0.15), despite the fact that 52.5 % of RF patients add additional complex fractionated atrial electrogram ablation, as well as left atrial linear ablation in over two-thirds (roof line in 67.8 % and mitral isthmus in 32.2 %). On multivariate Cox regression, only AF duration in years (HR = 1.10, 95 %CI 1.01-1.10, P = 0.04) was a predictor of relapse. Patients undergoing RF ablation presented a numerically, but non-significantly, lower complication rate (6.8 vs 10.2 %, P = 0.51). In our multicenter experience, freedom from atrial arrhythmias was comparable among matched patients treated with CRYO and RF, despite non-significant trends in favor of RF in terms of complications, at the cost of longer procedure times.

  13. Incidences of esophageal injury during esophageal temperature monitoring: a comparative study of a multi-thermocouple temperature probe and a deflectable temperature probe in atrial fibrillation ablation.

    PubMed

    Kuwahara, Taishi; Takahashi, Atsushi; Takahashi, Yoshihide; Okubo, Kenji; Takagi, Katsumasa; Fujino, Tadashi; Kusa, Shigeki; Takigawa, Masateru; Watari, Yuji; Yamao, Kazuya; Nakashima, Emiko; Kawaguchi, Naohiko; Hikita, Hiroyuki; Sato, Akira; Aonuma, Kazutaka

    2014-04-01

    The study aim was to compare the incidence of esophageal injuries between different temperature probes in the monitoring of esophageal temperature during atrial fibrillation (AF) ablation. One hundred patients with drug-resistant AF were prospectively and randomly assigned into two groups according to the esophageal temperature probe used: the multi-thermocouple probe group (n = 50) and the deflectable temperature probe group (n = 50). Extensive pulmonary vein (PV) isolation was performed with a 3.5-mm open irrigated tip ablation catheter by using a radiofrequency (RF) power of 25-30 W. In both groups, the esophageal temperature thermocouple was placed on the area of the esophagus adjacent to the ablation site. When the esophageal temperature reached 42 °C, the RF energy delivery was stopped. Esophageal endoscopy was performed 1 day after the catheter ablation. No differences existed between the two groups in terms of clinical background and various parameters related to the catheter ablation, including RF delivery time and number of RF deliveries at an esophageal temperature of >42 °C. Esophageal lesions, such as esophagitis and esophageal ulcers, occurred in 10/50 (20 %) and 15/50 (30 %) patients in the multi-thermocouple and deflectable temperature probe groups, respectively (P = 0.25). Most lesions were mild to moderate injuries, and all were cured using conservative treatment. The incidence of esophageal injury was almost equal between the multi-thermocouple temperature probe and the deflectable temperature probe during esophageal temperature monitoring. Most of the esophageal lesions that developed during esophageal temperature monitoring were mild to moderate and reversible.

  14. Atrial Fibrillation and Pulmonary Venous Electrical Conduction Recovery After Full Surgical Resection and Anastomosis of the Pulmonary Veins: Insights From Follow-Up and Ablation Procedures in Lung Transplant Recipients.

    PubMed

    Hussein, Ayman A; Panchabhai, Tanmay S; Budev, Marie M; Tarakji, Khaldoun; Barakat, Amr F; Saliba, Walid; Lindsay, Bruce; Wazni, Oussama M

    2017-06-01

    The authors report their experience with atrial fibrillation (AF) rates and ablation findings in lung transplant recipients. Pulmonary venous (PV) conduction recovery accounts for most failed atrial fibrillation (AF) catheter ablation procedures. Lung transplantation involves full surgical resection and replacement of the recipient's PVs with donor's PVs, which may represent the ultimate PV ablation. They followed 755 consecutive lung transplant recipients categorized based on transplant status (unilateral vs. bilateral) and pre-transplant AF. In patients without pre-transplant AF (n = 704), late AF (beyond 6 months after transplant) occurred in 2.5% and 3.3% of unilateral or bilateral lung transplants, respectively. In patients with pre-transplant AF (n = 51), AF recurred in 19.4% and 25.0% of bilateral and unilateral transplants, respectively. In a subset of patients who underwent left atrial ablations after transplant for recurrent refractory AF (n = 8), PV conduction recovery across the surgical anastomoses lines was observed in 22 of 26 previously disconnected PVs. Conduction recovery was observed in ≥1 vein in all but 1 patient. Re-isolation of the veins with additional substrate modification/flutter ablations successfully restored and maintained sinus rhythm in 7 of 8 patients. In lung transplant recipients who undergo full surgical resection of the PVs, a prior history of AF was associated with late AF, regardless of whether patients underwent single or bilateral lung transplantation. PV conduction recovery still occurred and was observed in most patients who underwent left atrial ablation procedures for recurrent AF. Copyright © 2017. Published by Elsevier Inc.

  15. Acute and long term outcomes of catheter ablation using remote magnetic navigation for the treatment of electrical storm in patients with severe ischemic heart failure.

    PubMed

    Jin, Qi; Jacobsen, Peter Karl; Pehrson, Steen; Chen, Xu

    2015-03-15

    Catheter ablation with remote magnetic navigation (RMN) can offer some advantages compared to manual techniques. However, the relevant clinical evidence for how RMN-guided ablation affects electrical storm (ES) due to ventricular tachycardia (VT) in patients with severe ischemic heart failure (SIHF) is still limited. Forty consecutive SIHF patients (left ventricular ejection fraction, 21 ± 6.9%) presenting with ES underwent ablation using RMN. All the patients received implantable cardioverter-defibrillators (ICDs) either before or after ablation. Acute ablation success was defined as noninducibility of any sustained monophasic VT at the end of the procedure. Long-term analysis addressed VT recurrence, ICD therapies and all-cause death. ES was acutely suppressed by ablation in all patients. Acute ablation success was obtained in 32 of 40 (80%) patients. The procedure time and fluoroscopy time were 105 ± 27 min and 7.5 ± 4.8 min respectively. No major complications occurred during procedures. During a mean follow-up of 17.4 months, 19 patients (47.5%) remained free of VT recurrence. The percentage of patients receiving ICD shocks after ablation was lower than before ablation (30% vs 69%, P<0.01). The mean number of ICD shocks per individual per year was reduced from 4.3 before ablation to 1.9 after ablation (P<0.05). Ten patients died during follow-up. Acute catheter ablation with RMN is safe and effective to suppress ES in SIHF patients. RMN-guided catheter ablation can prevent VT recurrence and significantly reduce ICD shocks, suggesting that this strategy can be used as an alternative therapy for VT storm in SIHF patients with ICDs. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  16. Loss of pace capture on the ablation line: a new marker for complete radiofrequency lesions to achieve pulmonary vein isolation.

    PubMed

    Steven, Daniel; Reddy, Vivek Y; Inada, Keiichi; Roberts-Thomson, Kurt C; Seiler, Jens; Stevenson, William G; Michaud, Gregory F

    2010-03-01

    Catheter ablation procedures for atrial fibrillation (AF) often involve circumferential antral isolation of pulmonary veins (PV). Inability to reliably identify conduction gaps on the ablation line necessitates placing additional lesions within the intended lesion set. This pilot study investigated the relationship between loss of pace capture directly along the ablation line and electrogram criteria for PV isolation (PVI). Using a 3-dimensional anatomic mapping system and irrigated-tip radiofrequency (RF) ablation catheter, lesions were placed in the PV antra to encircle ipsilateral vein pairs until pace capture at 10 mA/2 ms no longer occurred along the line. During ablation, a circular mapping catheter was placed in an ipsilateral PV, but the electrograms were not revealed until loss-of-pace capture. The procedural end point was PVI (entrance and exit block). Thirty patients (57 +/- 12 years; 15 male [50%]) undergoing PVI in 2 centers (3 primary operators) were included (left atrial diameter 40 +/- 4 mm, left ventricular ejection fraction 60 +/- 7%). All patients reached the end points of complete PVI and loss of pace capture. When PV electrograms were revealed after loss of pace capture along the line, PVI was present in 57 of 60 (95%) vein pairs. In the remaining 3 of 60 (5%) PV pairs, further RF applications achieved PVI. The procedure duration was 237 +/- 46 minutes, with a fluoroscopy time of 23 +/- 9 minutes. Analysis of the blinded PV electrograms revealed that even after PVI was achieved, additional sites of pace capture were present on the ablation line in 30 of 60 (50%) of the PV pairs; 10 +/- 4 additional RF lesions were necessary to fully achieve loss of pace capture. After ablation, the electrogram amplitude was lower at unexcitable sites (0.25 +/- 0.15 mV vs. 0.42 +/- 0.32 mV, P < .001), but there was substantial overlap with pace capture sites, suggesting that electrogram amplitude lacks specificity for identifying pace capture sites. Complete

  17. Cryo-balloon catheter localization in fluoroscopic images

    NASA Astrophysics Data System (ADS)

    Kurzendorfer, Tanja; Brost, Alexander; Jakob, Carolin; Mewes, Philip W.; Bourier, Felix; Koch, Martin; Kurzidim, Klaus; Hornegger, Joachim; Strobel, Norbert

    2013-03-01

    Minimally invasive catheter ablation has become the preferred treatment option for atrial fibrillation. Although the standard ablation procedure involves ablation points set by radio-frequency catheters, cryo-balloon catheters have even been reported to be more advantageous in certain cases. As electro-anatomical mapping systems do not support cryo-balloon ablation procedures, X-ray guidance is needed. However, current methods to provide support for cryo-balloon catheters in fluoroscopically guided ablation procedures rely heavily on manual user interaction. To improve this, we propose a first method for automatic cryo-balloon catheter localization in fluoroscopic images based on a blob detection algorithm. Our method is evaluated on 24 clinical images from 17 patients. The method successfully detected the cryoballoon in 22 out of 24 images, yielding a success rate of 91.6 %. The successful localization achieved an accuracy of 1.00 mm +/- 0.44 mm. Even though our methods currently fails in 8.4 % of the images available, it still offers a significant improvement over manual methods. Furthermore, detecting a landmark point along the cryo-balloon catheter can be a very important step for additional post-processing operations.

  18. Zero-fluoroscopy cryothermal ablation of atrioventricular nodal re-entry tachycardia guided by endovascular and endocardial catheter visualization using intracardiac echocardiography (Ice&ICE Trial).

    PubMed

    Luani, Blerim; Zrenner, Bernhard; Basho, Maksim; Genz, Conrad; Rauwolf, Thomas; Tanev, Ivan; Schmeisser, Alexander; Braun-Dullaeus, Rüdiger C

    2018-01-01

    Stochastic damage of the ionizing radiation to both patients and medical staff is a drawback of fluoroscopic guidance during catheter ablation of cardiac arrhythmias. Therefore, emerging zero-fluoroscopy catheter-guidance techniques are of great interest. We investigated, in a prospective pilot study, the feasibility and safety of the cryothermal (CA) slow-pathway ablation in patients with symptomatic atrioventricular-nodal-re-entry-tachycardia (AVNRT) using solely intracardiac echocardiography (ICE) for endovascular and endocardial catheter visualization. Twenty-five consecutive patients (mean age 55.6 ± 12.0 years, 17 female) with ECG-documentation or symptoms suggesting AVNRT underwent an electrophysiology study (EPS) in our laboratory utilizing ICE for catheter navigation. Supraventricular tachycardia was inducible in 23 (92%) patients; AVNRT was confirmed by appropriate stimulation maneuvers in 20 (80%) patients. All EPS in the AVNRT subgroup could be accomplished without need for fluoroscopy, relying solely on ICE-guidance. CA guided by anatomical location and slow-pathway potentials was successful in all patients, median cryo-mappings = 6 (IQR:3-10), median cryo-ablations = 2 (IQR:1-3). Fluoroscopy was used to facilitate the trans-septal puncture and localization of the ablation substrate in the remaining 3 patients (one focal atrial tachycardia and two atrioventricular-re-entry-tachycardias). Mean EPS duration in the AVNRT subgroup was 99.8 ± 39.6 minutes, ICE guided catheter placement 11.9 ± 5.8 minutes, time needed for diagnostic evaluation 27.1 ± 10.8 minutes, and cryo-application duration 26.3 ± 30.8 minutes. ICE-guided zero-fluoroscopy CA in AVNRT patients is feasible and safe. Real-time visualization of the true endovascular borders and cardiac structures allow for safe catheter navigation during the ICE-guided EPS and might be an alternative to visualization technologies using geometry reconstructions. © 2017 Wiley Periodicals, Inc.

  19. Ablation of Rotor and Focal Sources Reduces Late Recurrence of Atrial Fibrillation Compared to Trigger Ablation Alone

    PubMed Central

    Narayan, Sanjiv M.; Baykaner, Tina; Clopton, Paul; Schricker, Amir; Lalani, Gautam; Krummen, David E.; Shivkumar, Kalyanam; Miller, John M.

    2014-01-01

    Objectives To determine if ablation that targets patient-specific AF-sustaining substrates (rotors or focal sources) is more durable than trigger ablation alone at preventing late AF recurrences. Background Late recurrence substantially limits the efficacy of pulmonary vein (PV) isolation for AF, and is associated with PV reconnection and the emergence of new triggers. Methods We performed 3 year follow-up of the CONFIRM trial, in which 92 consecutive AF patients (70.7% persistent) underwent novel computational mapping to reveal a median of 2 (IQR 1–2) rotors or focal sources in 97.7% of patients during AF. Ablation comprised source (Focal Impulse and Rotor Modulation, FIRM) then conventional ablation in n=27 (FIRM-guided), and conventional ablation alone in n=65 (FIRM-blinded). Patients were followed with implanted ECG monitors when possible (85.2% FIRM guided, 23.1% FIRM-blinded). Results On 890 days follow-up (median; IQR 224–1563) compared FIRM-blinded therapy, patients receiving FIRM-guided ablation maintained higher freedom from AF after 1.2±0.4 procedures (median 1, IQR 1–1) (77.8% vs 38.5%; p=0.001) and a single procedure (p>0.001), and higher freedom from all atrial arrhythmias (p=0.003). Freedom from AF was higher when ablation directly or coincidentally passed through sources than when it missed sources (p>0.001). CONCLUSIONS FIRM-guided ablation is more durable than conventional trigger-based ablation at preventing 3 year AF recurrence. Future studies should investigate how ablation of patient-specific AF-sustaining rotors and focal sources alters the natural history of arrhythmia recurrence. PMID:24632280

  20. Catheter ablation of ventricular ectopy with para-hisian origin: importance of mapping both sides of the interventricular septum and understanding when to stop ablating.

    PubMed

    Madaffari, Antonio; Große, Anett; Raffa, Santi; Frommhold, Markus; Fink, Agnes; Geller, J Christoph

    2016-12-01

    Catheter ablation of para-Hisian premature ventricular contractions (PVCs) still represents a challenge and is a compromise between success and inadvertent AV block. We describe a possible strategy to address PVCs from this location with high-amplitude His-bundle potentials at the site of earliest activation.

  1. Pulmonary vein anatomy predicts freedom from atrial fibrillation using remote magnetic navigation for circumferential pulmonary vein ablation.

    PubMed

    Sohns, Christian; Sohns, Jan M; Bergau, Leonard; Sossalla, Samuel; Vollmann, Dirk; Lüthje, Lars; Staab, Wieland; Dorenkamp, Marc; Harrison, James L; O'Neill, Mark D; Lotz, Joachim; Zabel, Markus

    2013-08-01

    Multidetector computed tomography (MDCT) is frequently used to guide circumferential pulmonary vein ablation (PVA) for treatment of atrial fibrillation (AF) as it offers accurate visualization of the left atrial (LA) and pulmonary vein (PV) anatomy. This study aimed to identify if PV anatomy is associated with outcomes following PVA using remote magnetic navigation (RMN). We analysed data from 138 consecutive patients and 146 ablation procedures referred for PVA due to drug-refractory symptomatic AF (age 63 ± 11 years; 57% men; 69% paroxysmal AF). The RMN using the stereotaxis system and open-irrigated 3.5 mm ablation catheters was used in all procedures. Prior to PVA, all patients underwent electrocardiogram-gated 64-MDCT for assessment of LA dimensions, PV anatomy, and electro-anatomical image integration during the procedure. Regular PV anatomy was found in 68%, a common left PV ostium was detected in 26%, and variant anatomy of the right PVs was detected in 6%. After a mean follow-up of 337 ± 102 days, 63% of the patients maintained sinus rhythm after the initial ablation, and 83% when including repeat PVA. Although acutely successful PV isolation did not differ between anatomical subgroups (regular 3.5 ± 0.8 vs. variant 3.2 ± 1.3; P = 0.31), AF recurrence was significantly higher in patients with non-regular PV anatomy (P = 0.04, hazard ratio 1.72). Pulmonary vein anatomy did not influence complication rates. Pulmonary vein anatomy assessed by MDCT is a good predictor of AF recurrence after PVA using RMN.

  2. Effect of vitamin K2 on the anticoagulant activity of warfarin during the perioperative period of catheter ablation: Population analysis of retrospective clinical data.

    PubMed

    Zhou, Zhi; Yano, Ikuko; Odaka, Sumiko; Morita, Yosuke; Shizuta, Satoshi; Hayano, Mamoru; Kimura, Takeshi; Akaike, Akinori; Inui, Ken-Ichi; Matsubara, Kazuo

    2016-01-01

    Catheter ablation is a non-medication therapy for atrial fibrillation, and during the procedure, warfarin is withdrawn in the preoperative period to prevent the risk of bleeding. In case of emergency, vitamin K2 can be intravenously administered to antagonize the anticoagulant activity of warfarin. The aims of this study were to conduct population pharmacokinetic/pharmacodynamic modeling for retrospective clinical data and to investigate the effect of vitamin K2 on the anticoagulant activity of warfarin in the perioperative period of catheter ablation. A total of 579 international normalized ratio (INR) values of prothrombin time from 100 patients were analyzed using the nonlinear mixed-effects modeling program NONMEM. A 1-compartment model was adapted to the pharmacokinetics of warfarin and vitamin K2, and the indirect response model was used to investigate the relationship between plasma concentration and the pharmacodynamic response of warfarin and vitamin K2. Since no plasma concentration data for warfarin and vitamin K2 were available, 3 literally available pharmacokinetic parameters were used to simultaneously estimate 1 pharmacokinetic parameter and 5 pharmacodynamic parameters. The population parameters obtained not only successfully explained the observed INR values, but also indicated an increase in sensitivity to warfarin in patients with reduced renal function. Simulations using these parameters indicated that vitamin K2 administration of more than 20 mg caused a slight dose-dependent decrease in INR on the day of catheter ablation and a delayed INR elevation after warfarin re-initiation. A pharmacokinetic/pharmacodynamic model was successfully built to explain the retrospective INR data during catheter ablation. Simulation studies suggest that vitamin K2 should be administered with care and that more than 20 mg is unnecessary in the preoperative period of catheter ablation.

  3. Real-time magnetic resonance-guided ablation of typical right atrial flutter using a combination of active catheter tracking and passive catheter visualization in man: initial results from a consecutive patient series.

    PubMed

    Hilbert, Sebastian; Sommer, Philipp; Gutberlet, Matthias; Gaspar, Thomas; Foldyna, Borek; Piorkowski, Christopher; Weiss, Steffen; Lloyd, Thomas; Schnackenburg, Bernhard; Krueger, Sascha; Fleiter, Christian; Paetsch, Ingo; Jahnke, Cosima; Hindricks, Gerhard; Grothoff, Matthias

    2016-04-01

    Recently cardiac magnetic resonance (CMR) imaging has been found feasible for the visualization of the underlying substrate for cardiac arrhythmias as well as for the visualization of cardiac catheters for diagnostic and ablation procedures. Real-time CMR-guided cavotricuspid isthmus ablation was performed in a series of six patients using a combination of active catheter tracking and catheter visualization using real-time MR imaging. Cardiac magnetic resonance utilizing a 1.5 T system was performed in patients under deep propofol sedation. A three-dimensional-whole-heart sequence with navigator technique and a fast automated segmentation algorithm was used for online segmentation of all cardiac chambers, which were thereafter displayed on a dedicated image guidance platform. In three out of six patients complete isthmus block could be achieved in the MR scanner, two of these patients did not need any additional fluoroscopy. In the first patient technical issues called for a completion of the procedure in a conventional laboratory, in another two patients the isthmus was partially blocked by magnetic resonance imaging (MRI)-guided ablation. The mean procedural time for the MR procedure was 109 ± 58 min. The intubation of the CS was performed within a mean time of 2.75 ± 2.21 min. Total fluoroscopy time for completion of the isthmus block ranged from 0 to 7.5 min. The combination of active catheter tracking and passive real-time visualization in CMR-guided electrophysiologic (EP) studies using advanced interventional hardware and software was safe and enabled efficient navigation, mapping, and ablation. These cases demonstrate significant progress in the development of MR-guided EP procedures. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2015. For permissions please email: journals.permissions@oup.com.

  4. An efficient cardiac mapping strategy for radiofrequency catheter ablation with active learning.

    PubMed

    Feng, Yingjing; Guo, Ziyan; Dong, Ziyang; Zhou, Xiao-Yun; Kwok, Ka-Wai; Ernst, Sabine; Lee, Su-Lin

    2017-07-01

    A major challenge in radiofrequency catheter ablation procedures is the voltage and activation mapping of the endocardium, given a limited mapping time. By learning from expert interventional electrophysiologists (operators), while also making use of an active-learning framework, guidance on performing cardiac voltage mapping can be provided to novice operators or even directly to catheter robots. A learning from demonstration (LfD) framework, based upon previous cardiac mapping procedures performed by an expert operator, in conjunction with Gaussian process (GP) model-based active learning, was developed to efficiently perform voltage mapping over right ventricles (RV). The GP model was used to output the next best mapping point, while getting updated towards the underlying voltage data pattern as more mapping points are taken. A regularized particle filter was used to keep track of the kernel hyperparameter used by GP. The travel cost of the catheter tip was incorporated to produce time-efficient mapping sequences. The proposed strategy was validated on a simulated 2D grid mapping task, with leave-one-out experiments on 25 retrospective datasets, in an RV phantom using the Stereotaxis Niobe ® remote magnetic navigation system, and on a tele-operated catheter robot. In comparison with an existing geometry-based method, regression error was reduced and was minimized at a faster rate over retrospective procedure data. A new method of catheter mapping guidance has been proposed based on LfD and active learning. The proposed method provides real-time guidance for the procedure, as well as a live evaluation of mapping sufficiency.

  5. Impact of acute atrial fibrillation termination and prolongation of atrial fibrillation cycle length on the outcome of ablation of persistent atrial fibrillation: A substudy of the STAR AF II trial.

    PubMed

    Kochhäuser, Simon; Jiang, Chen-Yang; Betts, Timothy R; Chen, Jian; Deisenhofer, Isabel; Mantovan, Roberto; Macle, Laurent; Morillo, Carlos A; Haverkamp, Wilhelm; Weerasooriya, Rukshen; Albenque, Jean-Paul; Nardi, Stefano; Menardi, Endrj; Novak, Paul; Sanders, Prashanthan; Verma, Atul

    2017-04-01

    Controversy exists about the impact of acute atrial fibrillation (AF) termination and prolongation of atrial fibrillation cycle length (AFCL) during ablation on long-term procedural outcome. The purpose of this study was to analyze the influence of AF termination and AFCL prolongation on freedom from AF in patients from the STAR AF II (Substrate and Trigger Ablation for Reduction of Atrial Fibrillation Trial-Part II) trial. Acute changes in AFCL and AF termination were collected during the index procedure of the STAR AF II trial and compared to recurrence of AF at 18 months. Recurrence was assessed by ECG, Holter (3, 6, 9, 12, 18 months), and weekly transtelephonic ECG monitoring for 18 months. AF terminated in 8% of the pulmonary vein isolation (PVI) arm, 45% in the PVI+complex electrogram arm, and 22% of the PVI+linear ablation arm (P <.001), but freedom from AF did not differ among the 3 groups (P = .15). Freedom from AF was significantly higher in patients who presented to the laboratory in sinus rhythm (SR) compared to those without AF termination (63% vs 44%, P = .007). Patients with AF termination had an intermediate outcome (53%) that was not significantly different from those in SR (P = .84) or those who did not terminate (P = .08). AF termination was a univariable predictor of success (P = .007), but by multivariable analysis, presence of early SR was the strongest predictor of success (hazard ratio 0.67, P = .004). Prolongation of AFCL was not predictive of 18-month freedom from AF. Acute AF termination and prolongation in AFCL did not consistently predict 18-month freedom from AF. Presence of SR before or early during the ablation was the strongest predictor of better outcome. Copyright © 2016 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  6. Robust classification of contact orientation between tissue and an integrated spectroscopy and radiofrequency ablation catheter

    NASA Astrophysics Data System (ADS)

    Zaryab, Mohammad; Singh-Moon, Rajinder P.; Hendon, Christine P.

    2017-02-01

    Using light-based catheters for radiofrequency ablation (RFA) therapies grants the ability to accurately derive tissue properties such as lesion depth and overtreatment from spectroscopic information. However, this information is heavily reliant on contact quality with the treatment area and the orientation of the catheter. Thus to improve assessments of tissue properties, this work utilizes Bayesian modelling to classify whether the catheter is indeed in proper contact with the tissue. Initially in-laboratory experiments were conducted with ten fresh swine hearts submerged in blood. A total of 1555 unique near infrared spectra were collected from a spectrometer using a light-based catheter and manually tagged as "full perpendicular contact," "angled contact," and "no contact," between the catheter and heart tissue. Three features were prominent in all spectra for distinguishing purposes: area underneath the spectra, an intensity "valley" between 730 nm and 800 nm, along with the slope between 850 nm and 1150 nm. A classifier featuring bootstrapping, adaboost, and k-means techniques was thus created and achieved a 96.05% accuracy in classifying full contact, 98.33% accuracy in classifying angled contact, and 100% accuracy in classifying no contact.

  7. Magnetic resonance imaging-compatible circular mapping catheter: an in vivo feasibility and safety study.

    PubMed

    Elbes, Delphine; Magat, Julie; Govari, Assaf; Ephrath, Yaron; Vieillot, Delphine; Beeckler, Christopher; Weerasooriya, Rukshen; Jais, Pierre; Quesson, Bruno

    2017-03-01

    Interventional cardiac catheter mapping is routinely guided by X-ray fluoroscopy, although radiation exposure remains a significant concern. Feasibility of catheter ablation for common flutter has recently been demonstrated under magnetic resonance imaging (MRI) guidance. The benefit of catheter ablation under MRI could be significant for complex arrhythmias such as atrial fibrillation (AF), but MRI-compatible multi-electrode catheters such as Lasso have not yet been developed. This study aimed at demonstrating the feasibility and safety of using a multi-electrode catheter [magnetic resonance (MR)-compatible Lasso] during MRI for cardiac mapping. We also aimed at measuring the level of interference between MR and electrophysiological (EP) systems. Experiments were performed in vivo in sheep (N = 5) using a multi-electrode, circular, steerable, MR-compatible diagnostic catheter. The most common MRI sequences (1.5T) relevant for cardiac examination were run with the catheter positioned in the right atrium. High-quality electrograms were recorded while imaging with a maximal signal-to-noise ratio (peak-to-peak signal amplitude/peak-to-peak noise amplitude) ranging from 5.8 to 165. Importantly, MRI image quality was unchanged. Artefacts induced by MRI sequences during mapping were demonstrated to be compatible with clinical use. Phantom data demonstrated that this 10-pole circular catheter can be used safely with a maximum of 4°C increase in temperature. This new MR-compatible 10-pole catheter appears to be safe and effective. Combining MR and multipolar EP in a single session offers the possibility to correlate substrate information (scar, fibrosis) and EP mapping as well as online monitoring of lesion formation and electrical endpoint. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2016. For permissions please email: journals.permissions@oup.com.

  8. [Thoracoscopic, epicardial ablation of atrial fibrillation using the COBRA Fusion system as the first part of hybrid ablation].

    PubMed

    Budera, P; Osmančík, P; Talavera, D; Fojt, R; Kraupnerová, A; Žďárská, J; Vaněk, T; Straka, Z

    2017-01-01

    Treatment of persistent and long-standing persistent atrial fibrillation is not successfully managed by methods of catheter ablation or pharmacotherapy. Hybrid ablation (i.e. combination of minimally invasive surgical ablation, followed by electrophysiological assessment and subsequent endocardial catheter ablation to complete the entire intended procedure) presents an ever more used and very promising treatment method. Patients underwent thoracoscopic ablation of pulmonary veins and posterior wall of the left atrium (the box-lesion) with use of the COBRA Fusion catheter; thoracoscopic occlusion of the left atrial appendage using the AtriClip system was also done in later patients. After 23 months, electrophysiological assessment and catheter ablation followed. In this article we summarize a strategy of the surgical part of the hybrid procedure performed in our centre. We describe the surgery itself (including possible periprocedural complications) and we also present our short-term results, especially with respect to subsequent electrophysiological findings. Data of the first 51 patients were analyzed. The first 25 patients underwent unilateral ablation; the mean time of surgery was 102 min. Subsequent 26 patients underwent the bilateral procedure with the mean surgery time of 160 min. Serious complications included 1 stroke, 1 phrenic nerve palsy and 2 surgical re-explorations for bleeding. After 1 month, 65% of patients showed sinus rhythm. The box-lesion was found complete during electrophysiological assessment in 38% of patients and after catheter ablation, 96% of patients were discharged in sinus rhythm. The surgical part of the hybrid procedure with use of the minimally invasive approach and the COBRA Fusion catheter is a well-feasible method with a low number of periprocedural complications. For electrophysiologists, it provides a very good basis for successful completion of the hybrid ablation.Key words: atrial fibrillation hybrid ablation - thoracoscopy

  9. Recent advances in rhythm control for atrial fibrillation

    PubMed Central

    Bond, Richard; Olshansky, Brian; Kirchhof, Paulus

    2017-01-01

    Atrial fibrillation (AF) remains a difficult management problem. The restoration and maintenance of sinus rhythm—rhythm control therapy—can markedly improve symptoms and haemodynamics for patients who have paroxysmal or persistent AF, but some patients fare well with rate control alone. Sinus rhythm can be achieved with anti-arrhythmic drugs or electrical cardioversion, but the maintenance of sinus rhythm without recurrence is more challenging. Catheter ablation of the AF triggers is more effective than anti-arrhythmic drugs at maintaining sinus rhythm. Whilst pulmonary vein isolation is an effective strategy, other ablation targets are being evaluated to improve sinus rhythm maintenance, especially in patients with chronic forms of AF. Previously extensive ablation strategies have been used for patients with persistent AF, but a recent trial has shown that pulmonary vein isolation without additional ablation lesions is associated with outcomes similar to those of more extensive ablation. This has led to an increase in catheter-based technology to achieve durable pulmonary vein isolation. Furthermore, a combination of anti-arrhythmic drugs and catheter ablation seems useful to improve the effectiveness of rhythm control therapy. Two large ongoing trials evaluate whether a modern rhythm control therapy can improve prognosis in patients with AF. PMID:29043080

  10. Catheter ablation for premature ventricular contractions and ventricular tachycardia in patients with heart failure.

    PubMed

    Kumar, Saurabh; Stevenson, William G; John, Roy M

    2014-09-01

    Ventricular arrhythmias (VA) are a significant contributor to morbidity and mortality in patients with heart failure (HF). Implantable cardioverter defibrillators are effective in reducing mortality, but do not prevent arrhythmia recurrence. There is increasing recognition that frequent premature ventricular contractions or repetitive ventricular tachycardia may also lead to new onset ventricular dysfunction or deterioration of ventricular function in patients with pre-existing HF. Suppression of the arrhythmia may lead to recovery of ventricular function. Catheter ablation has emerged as a safe and effective treatment option for reducing arrhythmia recurrence and for suppression of PVCs but its efficacy is governed by the nature of the arrhythmias, the underlying HF substrate and the accessibility of the arrhythmia substrates to ablation.

  11. Comparisons of the underlying mechanisms of left atrial remodeling after repeat circumferential pulmonary vein isolation with or without additional left atrial linear ablation in patients with recurrent atrial fibrillation.

    PubMed

    Yang, Chia-Hung; Chou, Chung-Chuan; Hung, Kuo-Chun; Wen, Ming-Shien; Chang, Po-Cheng; Wo, Hung-Ta; Lee, Cheng-Hung; Lin, Fen-Chiung

    2017-02-01

    Radiofrequency catheter ablation (RFCA) is a potentially curative treatment for atrial fibrillation (AF), however, whether or not additional left atrial (LA) linear ablation for recurrent AF adversely affects LA remodeling is unknown. Thirty-eight patients experiencing AF recurrence after the 1st circumferential pulmonary vein isolation (CPVI) underwent a repeat RFCA, including 20 and 18 patients receiving a repeat CPVI (group I) or CPVI plus LA linear ablation (group II), respectively. 2-D echocardiography was performed during sinus rhythm within 24h, at 1-m and 6-m after RFCA. Longitudinal strains and strain rate were measured with speckle-tracking echocardiography. The standard deviation of contraction duration was defined as LA mechanical dispersion. One and two patients experienced AF recurrence after the 2nd RFCA in group I and II, respectively (P=NS). The 1st CPVI with AF recurrence did not reduce LA size significantly in two groups. After a repeat CPVI, LA diameter but not LA maximal and minimal volume was significantly reduced in group I; additional LA linear ablation significantly decreased LA diameter, maximal and minimal volume in group II. However, there was no significant difference in LA emptying function, global and segmental LA strain and strain rate among the baseline, 1-m and 6-m follow-up in two groups. RFCA did not significantly increase LA mechanical dispersion regardless of the AF ablation strategies. In patients with recurrent AF, a successful repeat CPVI with or without additional LA linear ablation reduced LA size without significant deleterious effects on LA function and mechanical dispersion. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  12. Intrapericardial echocardiography: a novel catheter-based approach to cardiac imaging.

    PubMed

    Rodrigues, Ana Clara Tude; d'Avila, Andre; Houghtaling, Christopher; Ruskin, Jeremy N; Picard, Michael; Reddy, Vivek Y

    2004-03-01

    Transvascular catheter-based intracardiac echocardiography has been successfully used to help guide catheter ablation and electrophysiologic procedures. It has recently been demonstrated that catheters can be safely placed into the pericardial space to allow for epicardial cardiac mapping and ablation. We evaluated the feasibility of catheter-based intrapericardial echocardiography (IPE) during such procedures to identify cardiac structures and visualize intracardiac catheters. IPE was performed in 7 goats by placing a phased-array ultrasound transducer contained within a 10F steerable catheter into the pericardial space using the same transthoracic subxyphoid approach as used to map and ablate epicardial ventricular tachycardia. Images were obtained of cardiac structures and of intracardiac ablation catheters. After the procedure, the hearts were harvested to assess for possible IPE-related lesions. The IPE catheter could be easily placed inside the pericardial space in all animals. In 7 of 7 cases, longitudinal and short-axis views of right- and left-sided chambers and valves were obtained, similar in orientation to transesophageal echocardiography. Visualization of atrial appendages (6/7), pulmonary veins (6/7), coronary arteries (6/7), and coronary sinus (3/6) was also feasible. Assessment of intracardiac transvalvar and venous blood flow was achieved by spectral and color Doppler. The ablation catheter could be clearly visualized inside cardiac chambers. No arrhythmias were induced with IPE catheter manipulation. After harvesting the hearts, no lesions resulting from the procedure were observed. In this experimental setting, IPE was able to provide detailed images of cardiac structures and establish the relative position of the ablation catheter.

  13. Pediatric Catheter Ablation: Characteristics and Results of a Series in a Tertiary Referral Hospital.

    PubMed

    Alonso-García, Andrés; Atienza, Felipe; Ávila, Pablo; Ugueto, Clara; Centeno, Miriam; Álvarez, Reyes; Datino, Tomás; González-Torrecilla, Esteban; Castellanos, Evaristo; Loughlin, Gerard; Medrano, Constancio; Arenal, Ángel; Fernández-Avilés, Francisco

    2018-02-23

    Catheter ablation has become the treatment of choice in an increasing number of arrhythmias in children and adolescents. There is still limited evidence of its use at a national level in Spain. The aim was to describe the characteristics and results of a modern monocentric series form a referral tertiary care centre. Retrospective register of invasive procedures between 2004 and 2016 performed in patients under 17 years and recorded clinical characteristic, ablation methodology and acute and chronic results of the procedure. A total of 291 procedures in 224 patients were included. Median age was 12.2 years, 60% male. Overall, 46% patients were referred from other autonomous communities. The most frequent substrates were accessory pathways (AP) (70.2%,>50% septal AP localization) and atrioventricular nodal reentrant tachycardia (AVNRT) (15.8%). Congenital and acquired heart disease was frequent (16.8%). Cryoablation was used in 35.5% of the cases. Overall acute success of the primary procedure was 93.5% (AP 93.8%; AVNRT 100%). Redo procedures after recurrence were performed in 18.9% of all substrates, with a long-term cumulative efficacy of 98.4% (AP 99.3%; AVNRT 100%). One (0.37%) serious complication occurred, a case of complete atrioventricular block. Our study replicated previous international reports of high success rates with scarce complications in a high complexity series, confirming the safety and efficacy of pediatric catheter ablation in our environment performed at highly experienced referral centers. Copyright © 2017 Sociedad Española de Cardiología. Published by Elsevier España, S.L.U. All rights reserved.

  14. A comparative analysis of clinical outcomes and disposable costs of different catheter ablation methods for the treatment of atrioventricular nodal reentrant tachycardia

    PubMed Central

    Berman, Adam E; Rivner, Harold; Chalkley, Robin; Heboyan, Vahé

    2017-01-01

    Background Catheter ablation of atrioventricular nodal reentrant tachycardia (AVNRT) is a commonly performed electrophysiology (EP) procedure. Few data exist comparing conventional (CONV) versus novel ablation strategies from both clinical and direct cost perspectives. We sought to investigate the disposable costs and clinical outcomes associated with three different ablation methodologies used in the ablation of AVNRT. Methods We performed a retrospective review of AVNRT ablations performed at Augusta University Medical Center from 2006 to 2014. A total of 183 patients were identified. Three different ablation techniques were compared: CONV manual radiofrequency (RF) (n=60), remote magnetic navigation (RMN)-guided RF (n=67), and cryoablation (CRYO) (n=56). Results Baseline demographics did not differ between the three groups except for a higher prevalence of cardiomyopathy in the RMN group (p<0.01). The clinical end point of interest was recurrent AVNRT following the index ablation procedure. A significantly higher number of recurrent AVNRT cases occurred in the CRYO group as compared to CONV and RMN (p=0.003; OR =7.75) groups. Cost-benefit analysis showed both CONV and RMN to be dominant compared to CRYO. Cost-minimization analysis demonstrated the least expensive ablation method to be CONV (mean disposable catheter cost = CONV US$2340; CRYO US$3515; RMN US$5190). Despite comparable clinical outcomes, the incremental cost of RMN over CONV averaged US$3094 per procedure. Conclusion AVNRT ablation using either CONV or RMN techniques is equally effective and associated with lower AVNRT recurrence rates than CRYO. CONV ablation carries significant disposable cost savings as compared to RMN, despite similar efficacy. PMID:29138585

  15. A comparative analysis of clinical outcomes and disposable costs of different catheter ablation methods for the treatment of atrioventricular nodal reentrant tachycardia.

    PubMed

    Berman, Adam E; Rivner, Harold; Chalkley, Robin; Heboyan, Vahé

    2017-01-01

    Catheter ablation of atrioventricular nodal reentrant tachycardia (AVNRT) is a commonly performed electrophysiology (EP) procedure. Few data exist comparing conventional (CONV) versus novel ablation strategies from both clinical and direct cost perspectives. We sought to investigate the disposable costs and clinical outcomes associated with three different ablation methodologies used in the ablation of AVNRT. We performed a retrospective review of AVNRT ablations performed at Augusta University Medical Center from 2006 to 2014. A total of 183 patients were identified. Three different ablation techniques were compared: CONV manual radiofrequency (RF) (n=60), remote magnetic navigation (RMN)-guided RF (n=67), and cryoablation (CRYO) (n=56). Baseline demographics did not differ between the three groups except for a higher prevalence of cardiomyopathy in the RMN group ( p <0.01). The clinical end point of interest was recurrent AVNRT following the index ablation procedure. A significantly higher number of recurrent AVNRT cases occurred in the CRYO group as compared to CONV and RMN ( p =0.003; OR =7.75) groups. Cost-benefit analysis showed both CONV and RMN to be dominant compared to CRYO. Cost-minimization analysis demonstrated the least expensive ablation method to be CONV (mean disposable catheter cost = CONV US$2340; CRYO US$3515; RMN US$5190). Despite comparable clinical outcomes, the incremental cost of RMN over CONV averaged US$3094 per procedure. AVNRT ablation using either CONV or RMN techniques is equally effective and associated with lower AVNRT recurrence rates than CRYO. CONV ablation carries significant disposable cost savings as compared to RMN, despite similar efficacy.

  16. Fluoroless catheter ablation of various right and left sided supra-ventricular tachycardias in children and adolescents.

    PubMed

    Jan, Matevž; Žižek, David; Rupar, Katja; Mazić, Uroš; Kuhelj, Dimitrij; Lakič, Nikola; Geršak, Borut

    2016-11-01

    Electrophysiology study (EPS) and catheter ablation (CA) in children and adolescents carries a potentially harmful effect of radiation exposure when performed with the use of fluoroscopy. Our aim was to evaluate the feasibility, safety and effectiveness of fluoroless EPS and CA of various supra-ventricular tachycardias (SVTs) with the use of the 3D mapping system and intracardiac echocardiography (ICE). Forty-three consecutive children and adolescents (age 13 ± 3 years) underwent fluoroless EPS and CA for various supra-ventricular tachycardias. A three-dimensional (3D) mapping system NavX™ was used for guidance of diagnostic and ablation catheters in the heart. ICE was used as a fundamental imaging tool for transseptal punctures. Acute procedural success rate was 100 %. There were no procedure related complications and short-term follow up (10 ± 3 months) revealed 93 % arrhythmia free survival rate. Fluoroless CA of various SVTs in the paediatric population is feasible, safe and can be performed successfully with 3D mapping system and ICE.

  17. Evolution of Force Sensing Technologies.

    PubMed

    Shah, Dipen

    2017-06-01

    In order to Improve the procedural success and long-term outcomes of catheter ablation techniques for atrial fibrillation (AF), an Important unfulfilled requirement is to create durable electrophysiologically complete lesions. Measurement of contact force (CF) between the catheter tip and the target tissue can guide physicians to optimise both mapping and ablation procedures. Contact force can affect lesion size and clinical outcomes following catheter ablation of AF. Force sensing technologies have matured since their advent several years ago, and now allow the direct measurement of CF between the catheter tip and the target myocardium in real time. In order to obtain complete durable lesions, catheter tip spatial stability and stable contact force are important. Suboptimal energy delivery, lesion density/contiguity and/or excessive wall thickness of the pulmonary vein-left atrial (PV-LA) junction may result in conduction recovery at these sites. Lesion assessment tools may help predict and localise electrical weak points resulting in conduction recovery during and after ablation. There is increasing clinical evidence to show that optimal use of CF sensing during ablation can reduce acute PV re-conduction, although prospective randomised studies are desirable to confirm long-term favourable clinical outcomes. In combination with optimised lesion assessment tools, contact force sensing technology has the potential to become the standard of care for all patients undergoing AF catheter ablation.

  18. Predictability of lesion durability for AF ablation using phased radiofrequency: Power, temperature, and duration impact creation of transmural lesions.

    PubMed

    Hocini, Mélèze; Condie, Cathy; Stewart, Mark T; Kirchhof, Nicole; Foell, Jason D

    2016-07-01

    Long-term clinical outcomes for atrial fibrillation ablation depend on the creation of durable transmural lesions during pulmonary vein isolation and on substrate modification. Focal conventional radiofrequency (RF) ablation studies have demonstrated that tissue temperature and power are important factors for lesion formation. However, the impact and predictability of temperature and power on contiguous, transmural lesion formation with a phased RF system has not been described. The purpose of this study was to determine the sensitivity, specificity, and predictability of power and temperature to create contiguous, transmural lesions with the temperature-controlled, multielectrode phased RF PVAC GOLD catheter. Single ablations with the PVAC GOLD catheter were performed in the superior vena cava of 22 pigs. Ablations from 198 PVAC GOLD electrodes were evaluated by gross examination and histopathology for lesion transmurality and contiguity. Lesions were compared to temperature and power data from the phased RF GENius generator. Effective contact was defined as electrodes with a temperature of ≥50°C and a power of ≥3 W. Eighty-five percent (168 of 198) of the lesions were transmural and 79% (106 of 134) were contiguous. Electrode analysis showed that >30 seconds of effective contact identified transmural lesions with 85% sensitivity (95% confidence interval [CI] 78%-89%), 93% specificity (95% CI 76%-99%), and 99% positive predictive value (95% CI 94%-100%). Sensitivity for lesion contiguity was 95% (95% CI 89%-98%), with 62% specificity (95% CI 42%-78%) and 90% positive predictive value (95% CI 83%-95%). No char or coagulum was observed on the catheter or tissue. PVAC GOLD safely, effectively, and predictably creates transmural and contiguous lesions. Copyright © 2016 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  19. A Prospective Randomized Trial of Apixaban Dosing During Atrial Fibrillation Ablation: The AEIOU Trial.

    PubMed

    Reynolds, Matthew R; Allison, J Scott; Natale, Andrea; Weisberg, Ian L; Ellenbogen, Kenneth A; Richards, Mark; Hsieh, Wen-Hua; Sutherland, Julie; Cannon, Christopher P

    2018-05-01

    This study sought to determine whether uninterrupted apixaban would have similar rates of bleeding and thromboembolic events as does minimally interrupted apixaban at the time of atrial fibrillation (AF) ablation and to compare those results with rates in historical patients treated with uninterrupted warfarin. The safety, efficacy, and optimal dosing regimen for apixaban at the time of AF ablation are uncertain. This prospective, multicenter clinical trial enrolled 306 patients undergoing catheter ablation for nonvalvular AF and randomized 300 to uninterrupted versus minimally interrupted (holding 1 dose) periprocedural apixaban. A retrospective cohort of patients treated with uninterrupted warfarin at the same centers was matched to the apixaban-treated subjects for comparison. Endpoints included clinically significant bleeding, major bleeding, and nonhemorrhagic stroke or systemic embolism (SE) from the time of ablation through 30 days. There were no stroke or SE events. Clinically significant bleeding occurred in 11.3% of 150 evaluable patients on uninterrupted apixaban and 9.7% of 145 evaluable patients on interrupted apixaban (risk difference: 1.7% [95% confidence interval: -5.5% to 8.8%]; p = NS). Rates of major bleeding were 1.3% with uninterrupted apixaban, and 2.1% with interrupted (risk difference: -0.7%; p = NS). The rates of clinically significant and major bleeding were similar for all apixaban patients combined (10.5% and 1.7%), compared with the matched warfarin group (9.8% and 1.4%). Both uninterrupted and minimally interrupted apixaban at the time of AF ablation were associated with a very low rate of thromboembolic events, and rates of both major (<2%) and clinically significant bleeding were similar to uninterrupted warfarin. (Apixaban Evaluation of Interrupted Or Uninterrupted Anticoagulation for Ablation of Atrial Fibrillation [AEIOU]; NCT02608099). Copyright © 2018 American College of Cardiology Foundation. Published by Elsevier Inc

  20. Safety profile of multielectrode-phased radiofrequency pulmonary vein ablation catheter and irrigated radiofrequency catheter.

    PubMed

    Wasmer, K; Foraita, P; Leitz, P; Güner, F; Pott, C; Lange, P S; Eckardt, L; Mönnig, G

    2016-01-01

    Silent cerebral lesions with the multielectrode-phased radiofrequency (RF) pulmonary vein ablation catheter (PVAC(®)) have recently been investigated. However, comparative data on safety in relation to irrigated RF ablation are missing. One hundred and fifty consecutive patients (58 ± 12 years, 56 female) underwent first pulmonary vein isolation (PVI) for atrial fibrillation (61% paroxysmal) using PVAC(®) (PVAC). Procedure data as well as in-hospital complications were compared with 300 matched patients who underwent PVI using irrigated RF (iRF). Procedure duration (148 ± 63 vs. 208 ± 70 min; P < 0.001), RF duration (24 ± 10 vs. 49 ± 25 min; P < 0.001), and fluoroscopy time (21 ± 10 vs. 35 ± 13 min; P < 0.001) were significantly shorter using PVAC. Major complication rates [major bleeding, transitoric ischaemic attack (TIA), and pericardial tamponade] were not significantly different between groups (PVAC, n = 3; 2% vs. iRF n = 17; 6%). Overall complication rate, including minor events, was similar in both groups [n = 21 (14%) vs. n = 48 (16%)]. Most of these were bleeding complications due to vascular access [n = 8 (5.3%) vs. n = 22 (7.3%)], which required surgical intervention in five patients [n = 1 (0.7%) vs. n = 4 (1.3%)]. Pericardial effusion [n = 4 (2.7%) vs. n = 19 (6.3%); pericardial tamponade requiring drainage n = 0 vs. n = 6] occurred more frequently using iRF. Two patients in each group developed a TIA (1.3% vs. 0.6%). Of note, four of five thromboembolic events in the PVAC group (two TIAs and three transient ST elevations during ablation) occurred when all 10 electrodes were used for ablation. Pulmonary vein isolation using PVAC as a 'one-shot-system' has a comparable complication rate but a different risk profile. Pericardial effusion and tamponade occurred more frequently using iRF, whereas thromboembolic events were more prevalent using PVAC. Occurrence of clinically relevant thromboembolic events might be reduced by avoidance of electrode

  1. Patient specific optimization-based treatment planning for catheter-based ultrasound hyperthermia and thermal ablation

    NASA Astrophysics Data System (ADS)

    Prakash, Punit; Chen, Xin; Wootton, Jeffery; Pouliot, Jean; Hsu, I.-Chow; Diederich, Chris J.

    2009-02-01

    to model thermal ablation, including the addition of temperature dependent attenuation, perfusion, and tissue damage. Pilot point control at the target boundaries was implemented to control power delivery to each transducer section, simulating an approach feasible for MR guided procedures. The computer model of thermal ablation was evaluated on representative patient anatomies to demonstrate the feasibility of using catheter-based ultrasound thermal ablation for treatment of benign prostate hyperplasia (BPH) and prostate cancer, and to assist in designing applicators and treatment delivery strategies.

  2. Real-time circumferential mapping catheter tracking for motion compensation in atrial fibrillation ablation procedures

    NASA Astrophysics Data System (ADS)

    Brost, Alexander; Bourier, Felix; Wimmer, Andreas; Koch, Martin; Kiraly, Atilla; Liao, Rui; Kurzidim, Klaus; Hornegger, Joachim; Strobel, Norbert

    2012-02-01

    Atrial fibrillation (AFib) has been identified as a major cause of stroke. Radiofrequency catheter ablation has become an increasingly important treatment option, especially when drug therapy fails. Navigation under X-ray can be enhanced by using augmented fluoroscopy. It renders overlay images from pre-operative 3-D data sets which are then fused with X-ray images to provide more details about the underlying soft-tissue anatomy. Unfortunately, these fluoroscopic overlay images are compromised by respiratory and cardiac motion. Various methods to deal with motion have been proposed. To meet clinical demands, they have to be fast. Methods providing a processing frame rate of 3 frames-per-second (fps) are considered suitable for interventional electrophysiology catheter procedures if an acquisition frame rate of 2 fps is used. Unfortunately, when working at a processing rate of 3 fps, the delay until the actual motion compensated image can be displayed is about 300 ms. More recent algorithms can achieve frame rates of up to 20 fps, which reduces the lag to 50 ms. By using a novel approach involving a 3-D catheter model, catheter segmentation and a distance transform, we can speed up motion compensation to 25 fps which results in a display delay of only 40 ms on a standard workstation for medical applications. Our method uses a constrained 2-D/3-D registration to perform catheter tracking, and it obtained a 2-D tracking error of 0.61 mm.

  3. [Radiofrequency catheter ablation in children with Wolff-Parkinson-White syndrome and sudden cardiac death who had been resuscitated].

    PubMed

    Benito Bartolomé, F; Sánchez Fernández-Bernal, C

    2001-04-01

    Sudden death may be the first manifestation of the Wolff-Parkinson-White syndrome, especially in children and adolescents. The aim of this study was to evaluate the usefulness of radiofrequency catheter ablation in children with Wolff-Parkinson-White syndrome with aborted sudden death. We report four patients with Wolff-Parkinson-White syndrome who survived cardiac arrest. The patients were aged from 2.5 months to 16 years. The two first patients were lactating infants; in the first sudden death occurred during digoxin treatment for supraventricular tachycardia secondary to Wolff-Parkinson-White syndrome and in the second the syndrome was diagnosed after an episode of sudden death. In these patients a free wall accessory pathway (left posterior and left lateral, respectively) was successfully ablated using a transseptal approach. The third patient was diagnosed with asymptomatic Wolff-Parkinson-White syndrome; sudden death occurred during exercise. In the fourth patient, sudden death occurred after intravenous therapy with adenosine triphosphate and amiodarone for rapid atrial fibrillation. In both patients, one accessory pathway, located in right posteroseptal and right anterior free wall, respectively, was ablated. After a mean follow-up of 43.5 26.4 months, no recurrence of sudden death had occurred and electrocardiogram showed sinus rhythm without delta wave. The third patient presented severe sequelae of hypoxemic encephalopathy, which persisted during the follow-up. Radiofrequency catheter ablation is the treatment of choice in Wolff-Parkinson-White syndrome with episodes of aborted sudden death.

  4. Effect of pre-procedural interrupted apixaban on heparin anticoagulation during catheter ablation for atrial fibrillation: a prospective observational study.

    PubMed

    Bin Abdulhak, Aref A; Kennedy, Kevin F; Gupta, Sanjaya; Giocondo, Michael; Ramza, Brian; Wimmer, Alan P

    2015-11-01

    Effective intraprocedural anticoagulation is considered essential to minimize the risk of thromboembolism in catheter ablation (CA) of atrial fibrillation (AF). The effect of interrupted apixaban on intraprocedural heparin dosing requirements and levels of achieved anticoagulation with heparin has not been well studied. The purpose of the present study was to compare heparin administration and activated clotted times (ACTs) for patients undergoing CA for AF treated with interrupted apixaban before the procedure with patients on uninterrupted warfarin. Consecutive patients undergoing CA for AF treated with interrupted apixaban or uninterrupted warfarin were prospectively enrolled. Heparin administration determined by a standard protocol and normalized to patient weight and procedure duration, as well as rapidity, and degree of anticoagulation with heparin (as measured by mean ACT, peak ACT, time to ACT ≥300 s, and time to ACT ≥350 s) were compared between the groups. Forty-eight patients were enrolled (25 apixaban and 23 warfarin). Heparin administered by bolus (51.3 ± 21.5 vs 27.8 ± 9.6 units/kg/h; p < 0.001) and mean heparin drip rate (25.3 ± 3.6 vs 20.7 ± 2.4 units/kg/h; p < 0.001) were significantly higher in the apixaban group compared to the warfarin group. Despite greater heparin administration, apixaban patients achieved a significantly lower mean ACT (332.3 ± 17.0 vs 384.5 ± 53.9; p < 0.001) and peak ACT (369.5 ± 22.6 vs 432.3 ± 75.8, p < 0.001) compared to the warfarin group. The time to ACT ≥350 s (66.7 ± 35.8 vs 26.9 ± 34.0; p < 0.001) was significantly longer for apixaban-treated patients. Outcome differences persisted after analysis using linear models and Cox proportional hazard regression with adjustment for propensity scores. A standard intraprocedural heparin protocol results in delayed and lower levels of anticoagulation as measured by the ACT for interrupted apixaban

  5. Feasibility, Process, and Outcomes of Cardiovascular Clinical Trial Data Sharing: A Reproduction Analysis of the SMART-AF Trial.

    PubMed

    Gay, Hawkins C; Baldridge, Abigail S; Huffman, Mark D

    2017-12-01

    Data sharing is as an expanding initiative for enhancing trust in the clinical research enterprise. To evaluate the feasibility, process, and outcomes of a reproduction analysis of the THERMOCOOL SMARTTOUCH Catheter for the Treatment of Symptomatic Paroxysmal Atrial Fibrillation (SMART-AF) trial using shared clinical trial data. A reproduction analysis of the SMART-AF trial was performed using the data sets, data dictionary, case report file, and statistical analysis plan from the original trial accessed through the Yale Open Data Access Project using the SAS Clinical Trials Data Transparency platform. SMART-AF was a multicenter, single-arm trial evaluating the effectiveness and safety of an irrigated, contact force-sensing catheter for ablation of drug refractory, symptomatic paroxysmal atrial fibrillation in 172 participants recruited from 21 sites between June 2011 and December 2011. Analysis of the data was conducted between December 2016 and April 2017. Effectiveness outcomes included freedom from atrial arrhythmias after ablation and proportion of participants without any arrhythmia recurrence over the 12 months of follow-up after a 3-month blanking period. Safety outcomes included major adverse device- or procedure-related events. The SMART AF trial participants' mean age was 58.7 (10.8) years, and 72% were men. The time from initial proposal submission to final analysis was 11 months. Freedom from atrial arrhythmias at 12 months postprocedure was similar compared with the primary study report (74.0%; 95% CI, 66.0-82.0 vs 76.4%; 95% CI, 68.7-84.1). The reproduction analysis success rate was higher than the primary study report (65.8%; 95% CI 56.5-74.2 vs 75.6%; 95% CI, 67.2-82.5). Adverse events were minimal and similar between the 2 analyses, but contact force range or regression models could not be reproduced. The feasibility of a reproduction analysis of the SMART-AF trial was demonstrated through an academic data-sharing platform. Data sharing can be

  6. Thinking outside the Box: Rotor Modulation in the Treatment of Atrial Fibrillation.

    PubMed

    Sehra, Ruchir; Narayan, Sanjiv M; Hummel, John

    2013-01-01

    Ablation for atrial fibrillation (AF) is an important and exciting therapy whose results remain suboptimal. Although most clinical trials show that ablation eliminates AF more effectively than medications, it is disappointing that the continued single procedural success remains ≈50% despite the substantial advances that have taken place in imaging, catheter positioning and energy delivery. Focal impulse and rotor modulation (FIRM), on the other hand, offers the opportunity to precisely define and then ablate patient-specific sustaining mechanisms for AF, rather than trying to eliminate all possible AF triggers. For over a decade, electrophysiologists have described cases in which AF terminates after only limited ablation - usually that cannot be explained by 'random' meandering wavelets. Indeed, recent studies from several laboratories show that all forms of clinical AF are typically 'driven' by stable electrical rotors and focal sources, not by multiple meandering waves. FIRM mapping enables an operator to place a catheter at typically 1-3 predicted sites in the atria, and with <5-10 minutes of RF ablation, terminate AF and potentially render it non-inducible. Several independent laboratories have now shown that such FIRM ablation alone can terminate or substantially slow AF in >80% of patients with persistent and paroxysmal AF and increase the single procedure rate of AF elimination from 50% with PV isolation alone to >80%. Ongoing studies hint that FIRM only ablation, enabling ablation times in the range observed for typical atrial flutter, may also achieve these high success rates without subsequent trigger ablation. This review summarizes the current state-of-the-art on FIRM mapping and ablation.

  7. Microembolism and catheter ablation II: effects of cerebral microemboli injection in a canine model.

    PubMed

    Haines, David E; Stewart, Mark T; Barka, Noah D; Kirchhof, Nicole; Lentz, Linnea R; Reinking, Nicki M; Urban, Jon F; Halimi, Franck; Deneke, Thomas; Kanal, Emanuel

    2013-02-01

    Asymptomatic cerebral lesions have been observed on diffusion weighted MRI (DWI) scans shortly after catheter ablation of atrial fibrillation, but the pathogenesis of these lesions is incompletely understood. Twelve dogs underwent selective catheterization of the internal carotid or vertebral arteries. Either a microbubbled mixture of air (1.0-4.0 mL), blood, contrast, and saline (n=5), or heat-dried pulverized blood (particle size <600 μm) mixed with saline and contrast (n=6) was injected. One sham control experiment was performed. MRI scans were performed preinjection, and at 1, 2, and 4 days postinjection. Neurological tests were performed daily. Gross pathology and histopathology were performed on the brains after being euthanized on day 4. Three animals died <24 hours after injection. Hyperintense lesions were observed on DWI (median maximum diameter 3.1 mm) in 2 of 4 animals after air embolism and in 3 of 5 animals after particulate embolism. No DWI lesions were detected in the remaining 5 animals (including the sham control). Lesions seen on DWI and confirmed on the fluid attenuating inversion recovery sequence correlated well with anatomic lesions on histopathology. Cerebral embolization of air microbubbles or microparticulate debris that approximate the embolic sources from catheter ablation can create hyperintense DWI punctate lesions in a canine model. The location and size of the DWI/fluid attenuating inversion recovery lesions correlate with pathological findings.

  8. Capturing Pain in the Cortex during General Anesthesia: Near Infrared Spectroscopy Measures in Patients Undergoing Catheter Ablation of Arrhythmias

    PubMed Central

    Yücel, Meryem A.; Steele, Sarah C.; Alexander, Mark E.; Boas, David A.; Borsook, David; Becerra, Lino

    2016-01-01

    The predictability of pain makes surgery an ideal model for the study of pain and the development of strategies for analgesia and reduction of perioperative pain. As functional near-infrared spectroscopy reproduces the known functional magnetic resonance imaging activations in response to a painful stimulus, we evaluated the feasibility of functional near-infrared spectroscopy to measure cortical responses to noxious stimulation during general anesthesia. A multichannel continuous wave near-infrared imager was used to measure somatosensory and frontal cortical activation in patients undergoing catheter ablation of arrhythmias under general anesthesia. Anesthetic technique was standardized and intraoperative NIRS signals recorded continuously with markers placed in the data set for the timing and duration of each cardiac ablation event. Frontal cortical signals only were suitable for analysis in five of eight patients studied (mean age 14 ± 1 years, weight 66.7 ± 17.6 kg, 2 males). Thirty ablative lesions were recorded for the five patients. Radiofrequency or cryoablation was temporally associated with a hemodynamic response function in the frontal cortex characterized by a significant decrease in oxyhemoglobin concentration (paired t-test, p<0.05) with the nadir occurring in the period 4 to 6 seconds after application of the ablative lesion. Cortical signals produced by catheter ablation of arrhythmias in patients under general anesthesia mirrored those seen with noxious stimulation in awake, healthy volunteers, during sedation for colonoscopy, and functional Magnetic Resonance Imaging activations in response to pain. This study demonstrates the feasibility and potential utility of functional near-infrared spectroscopy as an objective measure of cortical activation under general anesthesia. PMID:27415436

  9. Capturing Pain in the Cortex during General Anesthesia: Near Infrared Spectroscopy Measures in Patients Undergoing Catheter Ablation of Arrhythmias.

    PubMed

    Kussman, Barry D; Aasted, Christopher M; Yücel, Meryem A; Steele, Sarah C; Alexander, Mark E; Boas, David A; Borsook, David; Becerra, Lino

    2016-01-01

    The predictability of pain makes surgery an ideal model for the study of pain and the development of strategies for analgesia and reduction of perioperative pain. As functional near-infrared spectroscopy reproduces the known functional magnetic resonance imaging activations in response to a painful stimulus, we evaluated the feasibility of functional near-infrared spectroscopy to measure cortical responses to noxious stimulation during general anesthesia. A multichannel continuous wave near-infrared imager was used to measure somatosensory and frontal cortical activation in patients undergoing catheter ablation of arrhythmias under general anesthesia. Anesthetic technique was standardized and intraoperative NIRS signals recorded continuously with markers placed in the data set for the timing and duration of each cardiac ablation event. Frontal cortical signals only were suitable for analysis in five of eight patients studied (mean age 14 ± 1 years, weight 66.7 ± 17.6 kg, 2 males). Thirty ablative lesions were recorded for the five patients. Radiofrequency or cryoablation was temporally associated with a hemodynamic response function in the frontal cortex characterized by a significant decrease in oxyhemoglobin concentration (paired t-test, p<0.05) with the nadir occurring in the period 4 to 6 seconds after application of the ablative lesion. Cortical signals produced by catheter ablation of arrhythmias in patients under general anesthesia mirrored those seen with noxious stimulation in awake, healthy volunteers, during sedation for colonoscopy, and functional Magnetic Resonance Imaging activations in response to pain. This study demonstrates the feasibility and potential utility of functional near-infrared spectroscopy as an objective measure of cortical activation under general anesthesia.

  10. Outcomes of Cryoballoon Ablation in High- and Low-Volume Atrial Fibrillation Ablation Centres: A Russian Pilot Survey

    PubMed Central

    Mikhaylov, Evgeny N.; Lebedev, Dmitry S.; Pokushalov, Evgeny A.; Davtyan, Karapet V.; Ivanitskii, Eduard A.; Nechepurenko, Anatoly A.; Kosonogov, Alexey Ya.; Kolunin, Grigory V.; Morozov, Igor A.; Termosesov, Sergey A.; Maykov, Evgeny B.; Khomutinin, Dmitry N.; Eremin, Sergey A.; Mayorov, Igor M.; Romanov, Alexander B.; Shabanov, Vitaliy V.; Shatakhtsyan, Victoria; Tsivkovskii, Viktor; Revishvili, Amiran Sh.; Shlyakhto, Evgeny V.

    2015-01-01

    Purpose. The results of cryoballoon ablation (CBA) procedure have been mainly derived from studies conducted in experienced atrial fibrillation (AF) ablation centres. Here, we report on CBA efficacy and complications resulting from real practice of this procedure at both high- and low-volume centres. Methods. Among 62 Russian centres performing AF ablation, 15 (24%) used CBA technology for pulmonary vein isolation. The centres were asked to provide a detailed description of all CBA procedures performed and complications, if encountered. Results. Thirteen sites completed interviews on all CBAs in their centres (>95% of CBAs in Russia). Six sites were high-volume AF ablation (>100 AF cases/year) centres, and 7 were low-volume AF ablation. There was no statistical difference in arrhythmia-free rates between high- and low-volume centres (64.6 versus 60.8% at 6 months). Major complications developed in 1.5% of patients and were equally distributed between high- and low-volume centres. Minor procedure-related events were encountered in 8% of patients and were more prevalent in high-volume centres. Total event and vascular access site event rates were higher in women than in men. Conclusions. CBA has an acceptable efficacy profile in real practice. In less experienced AF ablation centres, the major complication rate is equal to that in high-volume centres. PMID:26640789

  11. Impact of steerable sheaths on contact forces and reconnection sites in ablation for persistent atrial fibrillation.

    PubMed

    Ullah, Waqas; Hunter, Ross J; McLean, Ailsa; Dhinoja, Mehul; Earley, Mark J; Sporton, Simon; Schilling, Richard J

    2015-03-01

    In preclinical studies, catheter contact force (CF) during radiofrequency ablation correlates with the subsequent lesion size. We investigated the impact of steerable sheaths on ablation CF, its consistency, and wide area circumferential ablation (WACA) line reconnection sites. Five thousand and sixty-four ablations were analyzed across 60 patients undergoing first-time ablation for persistent AF using a CF-sensing catheter: 19 manual nonsteerable sheath (Manual-NSS), 11 manual steerable sheath, and 30 robotic steerable sheath (Sensei, Hansen Medical Inc.) procedures were studied. Ablation CFs were higher in the steerable sheath groups for all left atrial ablations and also WACA ablations specifically (P < 0.006), but less consistent per WACA segment (P < 0.005). There were significant differences in the CFs around both WACAs by group: in the left WACA CFs were lower with Manual-NSS, other than at the anterior-inferior and posterior-superior regions, and lower in the right WACA, other than the anterior-superior region. There was a difference in the proportion of segments chronically reconnecting across groups: Manual-NSS 26.5%, manual steerable sheath 4.6%, robotic 12% (P < 0.0005). The left atrial appendage/PV ridge and right posterior wall were common sites of reconnection in all groups. Steerable sheaths increased ablation CF; however, there were region-specific heterogeneities in the extent of increment, with some segments where they failed to increase CF. Steerable sheath use was associated with reduced WACA-segment reconnection. It may be that the benefits of steerable sheath use in terms of higher CFs could be translated to improved clinical outcomes if regional weaknesses of this technology are taken into account during ablation procedures. © 2014 Wiley Periodicals, Inc.

  12. Ex vivo human bile duct radiofrequency ablation with a bipolar catheter.

    PubMed

    Atar, Mustafa; Kadayifci, Abdurrahman; Daglilar, Ebubekir; Hagen, Catherine; Fernandez-Del Castillo, Carlos; Brugge, William R

    2018-06-01

    Management of the primary and secondary tumors of the bile ducts still remains as a major clinical challenge. Radiofrequency (RF) ablation (RFA) of these tumors is feasible but the effect of RF energy on the human common bile duct (CBD) and surrounding tissues has not been investigated. This pilot study aimed to determine the relationship between RF energy and the depth of ablation in the normal human CBD. The study was performed on fresh ex vivo human biliary-pancreatic tissue which had been resected for a pancreatic cyst or mass. The study was conducted within 15 min after resection. A bipolar Habib RFA catheter was placed into the middle of the intact CBD, and three different (5, 7, 10 W) power settings were applied over a 90-s period by an RF generator. Gross and histological examinations were performed. The depth of coagulation necrosis in CBD and the effect of RFA on CBD wall and surrounding pancreas tissue were determined by microscopic examination. The study included eight tissue samples. 5 W power was applied to three sites and RFA caused only focal epithelial necrosis limited to the CBD mucosa. 7 and 10 W were applied to five sites and coagulation necrosis occurred in all cases. Microscopically, necrosis was transmural, involved accessory bile duct glands, and extended to the surrounding pancreatic tissue in four of these cases. Macroscopically, RFA resulted in circumferential white-yellowish color change extending approximately 2 cm of the CBD. Bipolar RF energy application with 5 W resulted in limited ablation on CBD wall. However, 7 and 10 W generated tissue necrosis which extended through the CBD wall and into surrounding pancreas tissue. Endoscopic biliary RFA is an effective technique for local biliary tissue ablation but the use of high energy may injure surrounding tissue.

  13. Ablating Atrial Fibrillation: Customizing Lesion Sets Guided by Rotor Mapping.

    PubMed

    Zaman, Junaid A B; Narayan, Sanjiv M

    2015-01-01

    Ablation occupies an increasing role in the contemporary management of atrial fibrillation (AF), but results are suboptimal, particularly for persistent AF. While an anatomic approach to ablation is a highly efficacious and safe method to isolate pulmonary vein (PV) triggers, recurrence of AF is not always associated with PV reconnection, and there is compelling evidence that non-PV sites sustain AF after it is triggered. Recent developments in wide-area mapping and signal processing now identify rotors in the vast majority of AF patients that sustain AF and whose elimination improves long-term freedom from AF in multicenter studies. Investigators have now demonstrated rotor and focal sources for AF that show many analogous properties between approaches: they lie in spatially reproducible regions temporally over hours to days, and they are amenable to targeted ablation. This review outlines the rationale and technical developments supporting this mechanistic paradigm for human AF, and discusses how rotor mapping may be implemented for individual patient customization of lesion sets. Mechanistic studies are required to explain why rotor elimination (or other ablation approaches) producing long-term elimination of AF may not always terminate AF acutely, how AF correlates with structural changes on magnetic resonance imaging, and how these findings can be integrated clinically with current ablation strategies to improve patient outcomes.

  14. Critical phase transitions during ablation of atrial fibrillation

    NASA Astrophysics Data System (ADS)

    Iravanian, Shahriar; Langberg, Jonathan J.

    2017-09-01

    Atrial fibrillation (AF) is the most common sustained cardiac arrhythmia with significant morbidity and mortality. Pharmacological agents are not very effective in the management of AF. Therefore, ablation procedures have become the mainstay of AF management. The irregular and seemingly chaotic atrial activity in AF is caused by one or more meandering spiral waves. Previously, we have shown the presence of sudden rhythm organization during ablation of persistent AF. We hypothesize that the observed transitions from a disorganized to an organized rhythm is a critical phase transition. Here, we explore this hypothesis by simulating ablation in an anatomically-correct 3D AF model. In 722 out of 2160 simulated ablation, at least one sudden transition from AF to an organized rhythm (flutter) was noted (33%). They were marked by a sudden decrease in the cycle length entropy and increase in the mean cycle length. At the same time, the number of reentrant wavelets decreased from 2.99 ± 0.06 in AF to 1.76 ± 0.05 during flutter, and the correlation length scale increased from 13.3 ± 1.0 mm to 196.5 ± 86.6 mm (both P < 0.0001). These findings are consistent with the hypothesis that transitions from AF to an anatomical flutter behave as phase transitions in complex non-equilibrium dynamical systems with flutter acting as an absorbing state. Clinically, the facilitation of phase transition should be considered a novel mechanism of ablation and may help to design effective ablation strategies.

  15. Stand alone totally endoscopic epimyocardial ablation in patients with persistent atrial fibrillation and significant atrial dilatation.

    PubMed

    Wagner, Florian Mathias; Pecha, Simon; Conradi, Lenard; Reichenspurner, Hermann

    2015-05-01

    To analyze safety and efficacy of surgical totally endoscopic epimyocardial ablation in patients (pts) turned down for interventional catheter therapy due to long-standing persistent atrial fibrillation (pAF) combined with significant atrial dilatation (> 5 cm). Since December 2010, 15 pts were referred for surgical ablation due to persistent AF combined with biatrial dilatation (left atrium [LA] 5.0 ± 0.6 cm). Mean age was 52 ± 6 years, body mass index (BMI) 38 ± 6, duration of AF 2.8 ± 1.2 years, left ventricular end diastolic diameter (LVEDD) 5.8 cm ± 0.6 cm. Ablation was performed via a bilateral endoscopic approach using bipolar RF energy application. Monitoring was achieved by an event recorder (Reveal XT Medtronic, Inc., Minneapolis, MN, USA) or repeated 24-hours Holter electrocardiogram. All pts successfully received bilateral pulmonary vein isolation + box lesion + trigonal lesion + left atrial appendage resection. Mean duration of procedure was 235 ± 70 minutes. There was no intraoperative complication; however, one patient had persistent left phrenic nerve palsy. Mean hospital stay was 4 ± 2 days, mean follow-up time was 21 ± 11 months. Incidence of sinus rhythm (SR) was 67, 73, and 80% at discharge, three months, and 12 months follow-up. Mean LA diameter was reduced from 58.1 mm ± 6.0 mm preoperative to 49.7 mm ± 5.4 mm (p = 0.004) at 12 months follow-up. Incidence of SR was 86% at latest follow-up (mean time 21 months). All pts currently in SR (13/15 = 86%) are of class I or III antiarrhythmic drugs. Totally endoscopic left atrial ablation including left atrial resection can safely be performed. It achieved excellent rates of SR restoration in patients with long-standing persistent AF combined with significant atrial dilatation. © 2015 Wiley Periodicals, Inc.

  16. Microwave, irrigated, pulsed, or conventional radiofrequency energy source: which energy source for which catheter ablation?

    PubMed

    Erdogan, Ali; Grumbrecht, Stephan; Neumann, Thomas; Neuzner, Joerg; Pitschner, Heinz F

    2003-01-01

    The aim of the study was to compare the diameter of endomyocardial lesions induced with the delivery of microwave, cooled, or pulsed energy versus conventional RF energy. In vitro tests were performed in fresh endomyocardial preparations of pig hearts in a 10-L bath of NaCl 0.9% solution at 37 degrees C and constant 1.5 L/min flow. Ablation 7 Fr catheters with 4-mm tip electrodes were used, except for the delivery of microwave energy. Energy delivery time was set to 60 s/50 W in all experiments. Cooled energy delivery was performed with a closed irrigation catheter. Pulsed energy delivery was performed using a special controller with a duty-cycle of 5 ms. Microwave energy was delivered with a 2.5-GHz generator and 10-mm antenna. Electrode temperature and impedance were measured simultaneously. After ablation, lesion length, width, and depth were measured with microcalipers, and volume calculated by a formula for ellipsoid bodies. Each energy delivery mode was tested in ten experiments. The deepest lesions were created with cooled energy delivery, and the largest volume by microwave energy delivery. Pulsed RF produced significantly deeper lesions than conventional RF energy delivery. Cooled or pulsed RF energy delivery created deeper transmural lesions than conventional RF. To create linear lesions at anatomically complex sites (isthmus), microwave energy seemed superior by rapidly creating deep and long lesions.

  17. Low Rates of Major Complications for Radiofrequency Ablation of Atrial Fibrillation Maintained Over 14 Years: A Single Centre Experience of 2750 Consecutive Cases.

    PubMed

    Voskoboinik, Aleksandr; Sparks, Paul B; Morton, Joseph B; Lee, Geoffrey; Joseph, Stephen A; Hawson, Joshua J; Kistler, Peter M; Kalman, Jonathan M

    2018-02-03

    Despite technological advances, studies continue to report high complication rates for atrial fibrillation (AF) ablation. We sought to review complication rates for AF ablation at a high-volume centre over a 14-year period and identify predictors of complications. We reviewed prospectively collected data from 2750 consecutive AF ablation procedures at our institution using radiofrequency energy (RF) between January 2004 and May 2017. All cases were performed under general anaesthetic with transoesophageal echocardiography (TEE), 3D-mapping and an irrigated ablation catheter. Double transseptal puncture was performed under TEE guidance. All patients underwent wide antral circumferential isolation of the pulmonary veins (30W anteriorly, 25W posteriorly) with substrate modification at operator discretion. Of 2255 initial and 495 redo procedures, ablation strategies were: pulmonary vein isolation (PVI) only 2097 (76.3%), PVI+lines 368 (13.4%), PVI+posterior wall 191 (6.9%), PVI+cavotricuspid isthmus 277 (10.1%). There were 23 major (0.84%) and 20 minor (0.73%) complications. Cardiac tamponade (five cases - 0.18%) and phrenic nerve palsy (one case - 0.04%) rates were very low. Major vascular complications necessitating surgery or blood transfusion occurred in five patients (0.18%). There were no cases of death, permanent disability, atrio-oesophageal fistulae or symptomatic pulmonary vein (PV) stenosis, although there were five TEE probe-related complications (0.18%). Female gender (OR 2.14; 95% CI 1.07-4.26) but not age >70 (OR 1.01) was the only multivariate predictor of complications. Atrial fibrillation ablation performed at a high-volume centre using RF can be achieved with a low major complication rate in a representative AF population over a sustained period of time. Copyright © 2018 Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). Published by Elsevier B.V. All rights

  18. Long-term outcome of catheter ablation for left posterior fascicular ventricular tachycardia with the development of left posterior fascicular block and characteristics of repeat procedures.

    PubMed

    Luo, Bin; Zhou, Gongbu; Guo, Xiaogang; Liu, Xu; Yang, Jiandu; Sun, Qi; Ma, Jian; Zhang, Shu

    2017-06-01

    The present study aimed to retrospectively investigate long-term clinical outcomes of patients undergoing catheter ablation of left posterior fascicular ventricular tachycardia (LPF-VT) with the development of left posterior fascicular block (LPF block) and characteristics of repeat procedures. A total of 195 patients (mean age 29.76±1.03years, 16.4% females) who underwent catheter ablation for LPF-VT were consecutively enrolled. The earliest ventricular potential with a single fused Purkinje potential (PP) during VT and the PP located in the inferior-apical or mid-apical septum during SR were targeted for linear ablation. The endpoint of the procedure was noninducible VT and development of new-onset LPF block. Follow-up with clinic visits or telephonic interviews, electrocardiogram (ECG), or Holter monitoring was performed after the procedure. With a median follow-up of 85 (18,181) months, 20 patients were censored and 152 of 175 (86.86%) patients had long-term freedom from VT after a single procedure. No statistical difference in the outcome of catheter ablation of LPF-VT was found between inducible and non-inducible groups (P=0.89). Twenty-three patients exhibited recurrent LPF-VT. Seven of 23 patients developed new-onset left upper septal ventricular tachycardia that was successfully ablated. All the patients undergoing repeat procedures had freedom from VT. No procedural complications occurred. Ablation of LPF-VT using the development of LPF block as the endpoint is associated with a high procedural success rate. No difference in freedom from LPF-VT was found between inducible and non-inducible patients. New-onset LPF block recovery and non-early PP-QRS interval can be the predictors of LPF-VT repeat procedure. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. Ablating Atrial Fibrillation: Customizing Lesion Sets Guided by Rotor Mapping

    PubMed Central

    Zaman, Junaid A. B.; Narayan, Sanjiv M.

    2015-01-01

    Ablation occupies an increasing role in the contemporary management of atrial fibrillation (AF), but results are suboptimal, particularly for persistent AF. While an anatomic approach to ablation is a highly efficacious and safe method to isolate pulmonary vein (PV) triggers, recurrence of AF is not always associated with PV reconnection, and there is compelling evidence that non-PV sites sustain AF after it is triggered. Recent developments in wide-area mapping and signal processing now identify rotors in the vast majority of AF patients that sustain AF and whose elimination improves long-term freedom from AF in multicenter studies. Investigators have now demonstrated rotor and focal sources for AF that show many analogous properties between approaches: they lie in spatially reproducible regions temporally over hours to days, and they are amenable to targeted ablation. This review outlines the rationale and technical developments supporting this mechanistic paradigm for human AF, and discusses how rotor mapping may be implemented for individual patient customization of lesion sets. Mechanistic studies are required to explain why rotor elimination (or other ablation approaches) producing long-term elimination of AF may not always terminate AF acutely, how AF correlates with structural changes on magnetic resonance imaging, and how these findings can be integrated clinically with current ablation strategies to improve patient outcomes. PMID:26306123

  20. Incessant ventricular tachycardia early after acute myocardial infarction: efficacy of radiofrequency catheter ablation but not of optimal coronary revascularization.

    PubMed

    Bonanno, C; Ometto, R; Finocchi, G; Rulfo, F; La Vecchia, L; Vincenzi, M

    1999-12-01

    Incessant ventricular tachycardia is an arrhythmia refractory to conventional antiarrhythmic treatment. We describe the case of 55-year-old man who presented incessant ventricular tachycardia in the early post-acute phase of myocardial infarction. Optimal coronary revascularization was not effective, but radiofrequency catheter ablation was able to eliminate the anatomic substrate and clinical arrhythmic recurrence.

  1. Developing the Safety of Atrial Fibrillation Ablation Registry Initiative (SAFARI) as a collaborative pan-stakeholder critical path registry model: a Cardiac Safety Research Consortium "Incubator" Think Tank.

    PubMed

    Al-Khatib, Sana M; Calkins, Hugh; Eloff, Benjamin C; Kowey, Peter; Hammill, Stephen C; Ellenbogen, Kenneth A; Marinac-Dabic, Danica; Waldo, Albert L; Brindis, Ralph G; Wilbur, David J; Jackman, Warren M; Yaross, Marcia S; Russo, Andrea M; Prystowsky, Eric; Varosy, Paul D; Gross, Thomas; Pinnow, Ellen; Turakhia, Mintu P; Krucoff, Mitchell W

    2010-10-01

    Although several randomized clinical trials have demonstrated the safety and efficacy of catheter ablation of atrial fibrillation (AF) in experienced centers, the outcomes of this procedure in routine clinical practice and in patients with persistent and long-standing persistent AF remain uncertain. Brisk adoption of this therapy by physicians with diverse training and experience highlights potential concerns regarding the safety and effectiveness of this procedure. Some of these concerns could be addressed by a national registry of AF ablation procedures such as the Safety of Atrial Fibrillation Ablation Registry Initiative that was initially proposed at a Cardiac Safety Research Consortium Think Tank meeting in April 2009. In January 2010, the Cardiac Safety Research Consortium, in collaboration with the Duke Clinical Research Institute, the US Food and Drug Administration, the American College of Cardiology, and the Heart Rhythm Society, held a follow-up meeting of experts in the field to review the construct and progress to date. Other participants included the National Heart, Lung, and Blood Institute; the Centers for Medicare and Medicaid Services; the Agency for Healthcare Research and Quality; the AdvaMed AF working group; and additional industry representatives. This article summarizes the discussions that occurred at the meeting of the state of the Safety of Atrial Fibrillation Ablation Registry Initiative, the identification of a clear pathway for its implementation, and the exploration of solutions to potential issues in the execution of this registry. Copyright © 2010 Mosby, Inc. All rights reserved.

  2. Predictors of Long-term Success After Concomitant Surgical Ablation for Atrial Fibrillation.

    PubMed

    Pecha, Simon; Ghandili, Susanne; Hakmi, Samer; Willems, Stephan; Reichenspurner, Hermann; Wagner, Florian Mathias

    2017-01-01

    According to guidelines, atrial fibrillation (AF) ablation success should be measured by 24-hour Holter electrocardiogram (ECG). However, information on long-term success, especially obtained by 24-hour Holter ECG, is rare. We therefore analyzed rhythm course and long-term outcomes of our patients undergoing concomitant surgical AF ablation. Between January 2003 and April 2011, 486 patients underwent concomitant surgical AF ablation in our institution. Patients with 24-hour Holter ECG rhythm status available between 5 and 10 years postoperatively were included in this retrospective data analysis (n = 155). Ablation lesions were limited to either a pulmonary vein isolation (n = 31, 20%), a more complex left atrial lesion set (n = 89, 57%), or biatrial lesions (n = 35, 23%). Primary end point of the study was freedom from AF during long-term follow-up. Mean patient age was 68.1 ± 8.4 years; 57.4% were male. Mean follow-up time was 5.9 years. Surgical AF ablation provided freedom from AF rate of 56.6% during long-term follow-up, with significantly better results in patients with paroxysmal than in those with persistent AF (67.2% vs 51.8% P = 0.03). A stable rhythm course was observed during follow-up, without statistically significant differences between 12 months and latest follow-up (63.2% vs 56.6%; P = 0.25). In multivariate analysis, preoperative paroxysmal AF, duration of AF, and left atrial diameter were predictors of long-term ablation success. Surgical AF ablation provided freedom from AF rate of 56.6% during long-term follow-up. Statistically significant predictors of ablation success at latest follow-up were preoperative paroxysmal AF, duration of AF, and a preoperative smaller left atrial diameter. Copyright © 2017. Published by Elsevier Inc.

  3. Catheter ablation of ventricular tachycardias using remote magnetic navigation: a consecutive case-control study.

    PubMed

    Szili-Torok, Tamas; Schwagten, Bruno; Akca, Ferdi; Bauernfeind, Tamas; Abkenari, Lara Dabiri; Haitsma, David; Van Belle, Yves; Groot, Natasja D E; Jordaens, Luc

    2012-09-01

    Remote Magnetic Navigation for VT Ablation. This study aimed to compare acute and late outcomes of VT ablation using the magnetic navigation system (MNS) to manual techniques (MAN) in patients with (SHD) and without (NSHD) structural heart disease. Ablation data of 113 consecutive patients (43 SHD, 70 NSHD) with ventricular tachycardia treated with catheter ablation at our center were analyzed. Success rate, complications, procedure, fluoroscopy, and ablation times, and recurrence rates were systematically recorded for all patients. A total of 72 patients were included in the MNS group and 41 patients were included in the MAN group. Patient age, gender, and right ventricular and left ventricular VT were equally distributed. Acute success was achieved in 59 patients in the MNS group (82%) versus 27 (66%) patients in the MAN group (P = 0.046). Overall procedural time (177 ± 79 vs 232 ± 99 minutes, P < 0.01) and mean patient fluoroscopy time (27 ± 19 vs 56 ± 32 minutes, P < 0.001) were all significantly lower using MNS. In NSHD pts, higher acute success was achieved with MNS (83,7% vs 61.9%, P = 0.049), with shorter procedure times (151 ± 57 vs 210 ± 96, P = 0.011), whereas in SHD-VT these were not significantly different. No major complications occurred in the MNS group (0%) versus 1 cardiac tamponade and 1 significantly damaged ICD lead in the MAN group (4.9%, NS). After follow-up (20 ± 11 vs 20 ± 10 months, NS), VT recurred in 14 pts (23.7%) in the MNS group versus 12 pts (44.4%) in the MAN group (P = 0.047). The use of MNS offers advantages for ablation of NSHD-VT, while it offers similar efficacy for SHD-VT. (J Cardiovasc Electrophysiol, Vol. 23, pp. 948-954, September 2012). © 2012 Wiley Periodicals, Inc.

  4. Linear ablation of right atrial free wall flutter: demonstration of bidirectional conduction block as an endpoint associated with long-term success.

    PubMed

    Snowdon, Richard L; Balasubramaniam, Richard; Teh, Andrew W; Haqqani, Haris M; Medi, Caroline; Rosso, Raphael; Vohra, Jitendra K; Kistler, Peter M; Morton, Joseph B; Sparks, Paul B; Kalman, Jonathan M

    2010-05-01

    Ablation for atypical atrial flutter (AFL) is often performed during tachycardia, with termination or noninducibility of AFL as the endpoint. Termination alone is, however, an inadequate endpoint for typical AFL ablation, where incomplete isthmus block leads to high recurrence rates. We assessed conduction block across a low lateral right atrial (RA) ablation line (LRA) from free wall scar to the inferior vena cava (IVC) or tricuspid annulus in 11 consecutive patients with atypical RA free wall flutter. LRA block was assessed following termination of AFL, by pacing from the ablation catheter in the low lateral RA posterior to the ablation line and recording the sequence and timing of activation anterior to the line with a duodecapole catheter, and vice versa for bidirectional block. LRA block resulted in a high to low activation pattern on the halo and a mean conduction time of 201 +/- 48 ms to distal halo. LRA conduction block was present in only 2 out of 6 patients after termination of AFL by ablation. Ablation was performed during sinus rhythm (SR) in 9 patients to achieve LRA conduction block. No recurrence of AFL was observed at long-term follow-up (22 +/- 12 months); 3 patients developed AF. Termination of right free wall flutter is often associated with persistent LRA conduction and additional radiofrequency ablation (RFA) in SR is usually required. Low RA pacing may be used to assess LRA conduction block and offers a robust endpoint for atypical RA free wall flutter ablation, which results in a high long-term cure rate.

  5. Possible role for cryoballoon ablation of right atrial appendage tachycardia when conventional ablation fails.

    PubMed

    Amasyali, Basri; Kilic, Ayhan

    2015-06-01

    Focal atrial tachycardia arising from the right atrial appendage usually responds well to radiofrequency ablation; however, successful ablation in this anatomic region can be challenging. Surgical excision of the right atrial appendage has sometimes been necessary to eliminate the tachycardia and prevent or reverse the resultant cardiomyopathy. We report the case of a 48-year-old man who had right atrial appendage tachycardia resistant to multiple attempts at ablation with use of conventional radiofrequency energy guided by means of a 3-dimensional mapping system. The condition led to cardiomyopathy in 3 months. The arrhythmia was successfully ablated with use of a 28-mm cryoballoon catheter that had originally been developed for catheter ablation of paroxysmal atrial fibrillation. To our knowledge, this is the first report of cryoballoon ablation without isolation of the right atrial appendage. It might also be an alternative to epicardial ablation or surgery when refractory atrial tachycardia originates from the right atrial appendage.

  6. Features of intrinsic ganglionated plexi in both atria after extensive pulmonary isolation and their clinical significance after catheter ablation in patients with atrial fibrillation.

    PubMed

    Kurotobi, Toshiya; Shimada, Yoshihisa; Kino, Naoto; Ito, Kazato; Tonomura, Daisuke; Yano, Kentaro; Tanaka, Chiharu; Yoshida, Masataka; Tsuchida, Takao; Fukumoto, Hitoshi

    2015-03-01

    The features of intrinsic ganglionated plexi (GP) in both atria after extensive pulmonary vein isolation (PVI) and their clinical implications have not been clarified in patients with atrial fibrillation (AF). The purpose of this study was to assess the features of GP response after extensive PVI and to evaluate the relationship between GP responses and subsequent AF episodes. The study population consisted of 216 consecutive AF patients (104 persistent AF) who underwent an initial ablation. We searched for the GP sites in both atria after an extensive PVI. GP responses were determined in 186 of 216 patients (85.6%). In the left atrium, GP responses were observed around the right inferior GP in 116 of 216 patients (53.7%) and around the left inferior GP in 57 of 216 (26.4%). In the right atrium, GP responses were observed around the posteroseptal area: inside the CS in 64 of 216 patients (29.6%), at the CS ostium in 150 of 216 (69.4%), and in the lower right atrium in 45 of 216 (20.8%). The presence of a positive GP response was an independent risk factor for AF recurrence (hazard ratio 4.04, confidence interval 1.48-11.0) in patients with paroxysmal, but not persistent, AF. The incidence of recurrent atrial tachyarrhythmias in patients with paroxysmal AF with a positive GP response was 51% vs 8% in those without a GP response (P = .002). The presence of GP responses after extensive PVI was significantly associated with increased AF recurrence after ablation in patients with paroxysmal AF. Copyright © 2015 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  7. Pulmonary Hypertension due to Radiofrequency Catheter Ablation (RFCA) for Atrial Fibrillation: The Lungs, the Atrium or the Ventricle?

    PubMed

    Verma, Isha; Tripathi, Hemantkumar; Sikachi, Rutuja Rajanikant; Agrawal, Abhinav

    2016-12-01

    Atrial fibrillation is the most common heart rhythm disorder in United States, characterised by rapid and irregular beating of both the atria resulting in the similar ventricular response. While rate and rhythm control using pharmacological regimens remain the primary management strategies in these patients, radiofrequency catheter ablation (RFCA) is rapidly rising as an alternative modality of treatment. Increase in the incidence of RFCA has shed light on complications associated with this procedure. Pulmonary hypertension (PH) is one of the long-term complications that has been observed postcatheter ablation. There have been multiple mechanisms which have been proposed to explain these elevated pulmonary pressures. These include the involvement of the lungs due to pulmonary vein stenosis, pulmonary vein occlusion and, rarely, pulmonary embolism. Radiofrequency catheter ablation can also lead to scarring of the atrium which can cause left atrial diastolic dysfunction leading to elevated pulmonary pressures. Recently, it was also proposed that elevated pulmonary pressure was related to the unmasking of left ventricular diastolic dysfunction occurring after this procedure. In this article, we review all the mechanisms that are associated with the development of pulmonary hypertension in patients undergoing RCFA for atrial fibrillation and the approach to diagnosis and management of such patients. Copyright © 2016 Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). Published by Elsevier B.V. All rights reserved.

  8. Cryo-balloon catheter position planning using AFiT

    NASA Astrophysics Data System (ADS)

    Kleinoeder, Andreas; Brost, Alexander; Bourier, Felix; Koch, Martin; Kurzidim, Klaus; Hornegger, Joachim; Strobel, Norbert

    2012-02-01

    Atrial fibrillation (AFib) is the most common heart arrhythmia. In certain situations, it can result in life-threatening complications such as stroke and heart failure. For paroxsysmal AFib, pulmonary vein isolation (PVI) by catheter ablation is the recommended choice of treatment if drug therapy fails. During minimally invasive procedures, electrically active tissue around the pulmonary veins is destroyed by either applying heat or cryothermal energy to the tissue. The procedure is usually performed in electrophysiology labs under fluoroscopic guidance. Besides radio-frequency catheter ablation devices, so-called single-shot devices, e.g., the cryothermal balloon catheters, are receiving more and more interest in the electrophysiology (EP) community. Single-shot devices may be advantageous for certain cases, since they can simplify the creation of contiguous (gapless) lesion sets around the pulmonary vein which is needed to achieve PVI. In many cases, a 3-D (CT, MRI, or C-arm CT) image of a patient's left atrium is available. This data can then be used for planning purposes and for supporting catheter navigation during the procedure. Cryo-thermal balloon catheters are commercially available in two different sizes. We propose the Atrial Fibrillation Planning Tool (AFiT), which visualizes the segmented left atrium as well as multiple cryo-balloon catheters within a virtual reality, to find out how well cryo-balloons fit to the anatomy of a patient's left atrium. First evaluations have shown that AFiT helps physicians in two ways. First, they can better assess whether cryoballoon ablation or RF ablation is the treatment of choice at all. Second, they can select the proper-size cryo-balloon catheter with more confidence.

  9. Design, development and evaluation of a compact telerobotic catheter navigation system.

    PubMed

    Tavallaei, Mohammad Ali; Gelman, Daniel; Lavdas, Michael Konstantine; Skanes, Allan C; Jones, Douglas L; Bax, Jeffrey S; Drangova, Maria

    2016-09-01

    Remote catheter navigation systems protect interventionalists from scattered ionizing radiation. However, these systems typically require specialized catheters and extensive operator training. A new compact and sterilizable telerobotic system is described, which allows remote navigation of conventional tip-steerable catheters, with three degrees of freedom, using an interface that takes advantage of the interventionalist's existing dexterity skills. The performance of the system is evaluated ex vivo and in vivo for remote catheter navigation and ablation delivery. The system has absolute errors of 0.1 ± 0.1 mm and 7 ± 6° over 100 mm of axial motion and 360° of catheter rotation, respectively. In vivo experiments proved the safety of the proposed telerobotic system and demonstrated the feasibility of remote navigation and delivery of ablation. The proposed telerobotic system allows the interventionalist to use conventional steerable catheters; while maintaining a safe distance from the radiation source, he/she can remotely navigate the catheter and deliver ablation lesions. Copyright © 2015 John Wiley & Sons, Ltd. Copyright © 2015 John Wiley & Sons, Ltd.

  10. Planning the Safety of Atrial Fibrillation Ablation Registry Initiative (SAFARI) as a Collaborative Pan-Stakeholder Critical Path Registry Model: a Cardiac Safety Research Consortium "Incubator" Think Tank.

    PubMed

    Al-Khatib, Sana M; Calkins, Hugh; Eloff, Benjamin C; Packer, Douglas L; Ellenbogen, Kenneth A; Hammill, Stephen C; Natale, Andrea; Page, Richard L; Prystowsky, Eric; Jackman, Warren M; Stevenson, William G; Waldo, Albert L; Wilber, David; Kowey, Peter; Yaross, Marcia S; Mark, Daniel B; Reiffel, James; Finkle, John K; Marinac-Dabic, Danica; Pinnow, Ellen; Sager, Phillip; Sedrakyan, Art; Canos, Daniel; Gross, Thomas; Berliner, Elise; Krucoff, Mitchell W

    2010-01-01

    Atrial fibrillation (AF) is a major public health problem in the United States that is associated with increased mortality and morbidity. Of the therapeutic modalities available to treat AF, the use of percutaneous catheter ablation of AF is expanding rapidly. Randomized clinical trials examining the efficacy and safety of AF ablation are currently underway; however, such trials can only partially determine the safety and durability of the effect of the procedure in routine clinical practice, in more complex patients, and over a broader range of techniques and operator experience. These limitations of randomized trials of AF ablation, particularly with regard to safety issues, could be addressed using a synergistically structured national registry, which is the intention of the SAFARI. To facilitate discussions about objectives, challenges, and steps for such a registry, the Cardiac Safety Research Consortium and the Duke Clinical Research Institute, Durham, NC, in collaboration with the US Food and Drug Administration, the American College of Cardiology, and the Heart Rhythm Society, organized a Think Tank meeting of experts in the field. Other participants included the National Heart, Lung and Blood Institute, the Centers for Medicare and Medicaid Services, the Agency for Healthcare Research and Quality, the Society of Thoracic Surgeons, the AdvaMed AF working group, and additional industry representatives. The meeting took place on April 27 to 28, 2009, at the US Food and Drug Administration headquarters in Silver Spring, MD. This article summarizes the issues and directions presented and discussed at the meeting. Copyright 2010 Mosby, Inc. All rights reserved.

  11. Role of Rotors in the Ablative Therapy of Persistent Atrial Fibrillation

    PubMed Central

    Schricker, Amir A; Zaman, Junaid; Narayan, Sanjiv M

    2015-01-01

    Atrial fibrillation (AF) ablation is increasingly used to maintain sinus rhythm yet its results are sub-optimal, especially in patients with persistent AF or prior unsuccessful procedures. Attempts at improvement have often targeted substrates that sustain AF after it is triggered, yet those mechanisms are debated. Many studies now challenge the concept that AF is driven by self-sustaining disordered wavelets, showing instead that localised drivers (rotors) may drive disorder via a process known as fibrillatory conduction. Novel mapping using wide-area recordings, physiological filtering and phase analysis demonstrates rotors in human AF. Contact mapping with focal impulse and rotor modulation (FIRM) shows that localised ablation at sources can improve procedural success in many populations on long-term follow up and some newer approaches to rotor mapping are qualitatively similar. This review critically evaluates the data on rotor mapping and ablation, which advances our conceptual understanding of AF and holds the promise of substantially improving ablative outcomes in patients with persistent AF. PMID:26835100

  12. Real-time x-ray fluoroscopy-based catheter detection and tracking for cardiac electrophysiology interventions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ma Yingliang; Housden, R. James; Razavi, Reza

    2013-07-15

    Purpose: X-ray fluoroscopically guided cardiac electrophysiology (EP) procedures are commonly carried out to treat patients with arrhythmias. X-ray images have poor soft tissue contrast and, for this reason, overlay of a three-dimensional (3D) roadmap derived from preprocedural volumetric images can be used to add anatomical information. It is useful to know the position of the catheter electrodes relative to the cardiac anatomy, for example, to record ablation therapy locations during atrial fibrillation therapy. Also, the electrode positions of the coronary sinus (CS) catheter or lasso catheter can be used for road map motion correction.Methods: In this paper, the authors presentmore » a novel unified computational framework for image-based catheter detection and tracking without any user interaction. The proposed framework includes fast blob detection, shape-constrained searching and model-based detection. In addition, catheter tracking methods were designed based on the customized catheter models input from the detection method. Three real-time detection and tracking methods are derived from the computational framework to detect or track the three most common types of catheters in EP procedures: the ablation catheter, the CS catheter, and the lasso catheter. Since the proposed methods use the same blob detection method to extract key information from x-ray images, the ablation, CS, and lasso catheters can be detected and tracked simultaneously in real-time.Results: The catheter detection methods were tested on 105 different clinical fluoroscopy sequences taken from 31 clinical procedures. Two-dimensional (2D) detection errors of 0.50 {+-} 0.29, 0.92 {+-} 0.61, and 0.63 {+-} 0.45 mm as well as success rates of 99.4%, 97.2%, and 88.9% were achieved for the CS catheter, ablation catheter, and lasso catheter, respectively. With the tracking method, accuracies were increased to 0.45 {+-} 0.28, 0.64 {+-} 0.37, and 0.53 {+-} 0.38 mm and success rates increased to

  13. Remote magnetic navigation for mapping and ablating right ventricular outflow tract tachycardia.

    PubMed

    Thornton, Andrew S; Jordaens, Luc J

    2006-06-01

    Navigation, mapping, and ablation in the right ventricular outflow tract (RVOT) can be difficult. Catheter navigation using external magnetic fields may allow more accurate mapping and ablation. The purpose of this study was to assess the feasibility of RVOT tachycardia ablation using remote magnetic navigation. Mapping and ablation were performed in eight patients with outflow tract ventricular arrhythmias. Tachycardia mapping was undertaken with a 64-polar basket catheter, followed by remote activation and pace-mapping using a magnetically enabled catheter. The area of interest was localized on the basket catheter in seven patients in whom an RVOT arrhythmia was identified. Remote navigation of the magnetic catheter to this area was followed by pace-mapping. Ablation was performed at the site of perfect pace-mapping, with earliest activation if possible. Acute success was achieved in all patients (median four applications). Median procedural time was 144 minutes, with 13.4 minutes of patient fluoroscopy time and 3.8 minutes of physician fluoroscopy time. No complications occurred. One recurrence occurred during follow-up (mean 366 days). RVOT tachycardias can be mapped and ablated using remote magnetic navigation, initially guided by a basket catheter. Precise activation and pace-mapping are possible. Remote magnetic navigation permitted low fluoroscopy exposure for the physician. Long-term results are promising.

  14. Incidence of silent cerebral thromboembolic lesions after atrial fibrillation ablation may change according to technology used: comparison of irrigated radiofrequency, multipolar nonirrigated catheter and cryoballoon.

    PubMed

    Gaita, Fiorenzo; Leclercq, Jean François; Schumacher, Burghard; Scaglione, Marco; Toso, Elisabetta; Halimi, Franck; Schade, Anja; Froehner, Steffen; Ziegler, Volker; Sergi, Domenico; Cesarani, Federico; Blandino, Alessandro

    2011-09-01

    Silent cerebral ischemic lesions have recently emerged as the most frequent complications after pulmonary vein isolation (PVI). To reduce thromboembolic complications, new types of catheters and energy source have been introduced in clinical practice. The study purpose is to compare the incidence of new silent cerebral ischemic events in patients with paroxysmal atrial fibrillation (PAF) undergoing PVI with different ablation technologies. One hundred and eight patients (67% men; age 56 ± 9 years) with PAF were enrolled in a consecutive manner to undergo PVI performed with irrigated radiofrequency (RF) catheter (Group 1, 36 patients), multielectrode catheter (PVAC) associated with duty-cycled RF generator (Group 2, 36 patients) and cryoballoon (Group 3, 36 patients). The protocol included a cerebral magnetic resonance imaging before and after the procedure. After PVI, the following patients showed new silent cerebral ischemic lesions at postprocedural cerebral MRI: 3 patients in Group 1 (8.3%), 14 patients in Group 2 (38.9%), 2 patients in Group 3 (5.6%). PVAC related to higher incidence of silent cerebral ischemic events compared to irrigated RF (P = 0.002) and cryoballoon (P = 0.001), whereas no statistical differences were found between irrigated RF catheter and cryoballoon groups (8.3% vs 5.6%, P = 0.5). At the multivariate analysis, the only independent predictor of new ischemic asymptomatic cerebral lesions after PVI was ablation performed with PVAC (OR 1.48 95% CI 1.19-1.62, P < 0.001). The incidence of silent cerebral lesions after PVI is different depending on technologies used: PVAC increases the risk of 1.48 times compared to irrigated RF and cryoballoon ablation.  © 2011 Wiley Periodicals, Inc.

  15. Peri-procedural interrupted oral anticoagulation for atrial fibrillation ablation: comparison of aspirin, warfarin, dabigatran, and rivaroxaban

    PubMed Central

    Winkle, Roger A.; Mead, R. Hardwin; Engel, Gregory; Kong, Melissa H.; Patrawala, Rob A.

    2014-01-01

    Aims Atrial fibrillation ablation requires peri-procedural oral anticoagulation (OAC) to prevent thromboembolic events. There are several options for OAC. We evaluate peri-procedural AF ablation complications using a variety of peri-procedural OACs. Methods and results We examined peri-procedural OAC and groin, bleeding, and thromboembolic complications for 2334 consecutive AF ablations using open irrigated-tip radiofrequency (RF) catheters. Pre-ablation OAC was warfarin in 1113 (47.7%), dabigatran 426 (18.3%), rivaroxaban 187 (8.0%), aspirin 472 (20.2%), and none 136 (5.8%). Oral anticoagulation was always interrupted and intraprocedural anticoagulation was unfractionated heparin (activated clotting time, ACT = 237 ± 26 s). Pre- and post-OAC drugs were the same for 1591 (68.2%) and were different for 743 (31.8%). Following ablation, 693 (29.7%) were treated with dabigatran and 291 (12.5%) were treated with rivaroxaban. There were no problems changing from one OAC pre-ablation to another post-ablation. Complications included 12 (0.51%) pericardial tamponades [no differences for dabigatran (P = 0.457) or rivaroxaban (P = 0.163) compared with warfarin], 12 (0.51%) groin complications [no differences for rivaroxaban (P = 0.709) and fewer for dabigatran (P = 0.041) compared with warfarin]. Only 5 of 2334 (0.21%) required blood transfusions. There were two strokes (0.086%) and no transient ischaemic attacks (TIAs) in the first 48 h post-ablation. Three additional strokes (0.13%), and two TIAs (0.086%) occurred from 48 h to 30 days. Only one stroke had a residual deficit. Compared with warfarin, the neurologic event rate was not different for dabigatran (P = 0.684) or rivaroxaban (P = 0.612). Conclusion Using interrupted OAC, low target intraprocedural ACT, and irrigated-tip RF, the rate of peri-procedural groin, haemorrhagic, and thromboembolic complications was extremely low. There were only minimal differences between OACs. Low-risk patients may remain on aspirin

  16. Concurrent application of charge using a novel circuit prevents heat-related coagulum formation during radiofrequency ablation.

    PubMed

    Lim, Bernard; Venkatachalam, Kalpathi L; Jahangir, Arshad; Johnson, Susan B; Asirvatham, Samuel J

    2008-08-01

    Thromboembolism resulting from coagulum formation on the catheter and electrode surfaces is a serious complication with radiofrequency ablation procedures for heart rhythm disorders. Why coagulum occurs despite therapeutic heparinization is unclear. In this report, we demonstrate a novel approach to minimize coagulum formation based on the electromolecular characteristics of fibrinogen. Atomic force microscopy was used to establish that fibrinogen deposited on surfaces underwent conformational changes that resulted in spontaneous clot formation. We then immersed ablation catheters that were uncharged, negatively, or positively charged in heparinized blood for 30 minutes and noted the extent of clot formation. In separate experiments, ablation catheters were sutured to the ventricle of an excised porcine heart immersed in whole, heparinized blood and radiofrequency ablation performed for 5 minutes with and without charge delivered to the catheter tips. Electron microscopy of the catheter tips showed surface coverage of fibrin clot of the catheter to be 33.8% for negatively charged catheters, compared with 84.7% (P = 0.01) in noncharged catheters. There was no significant difference in surface coverage of fibrin clot between positively charged catheters (93.8%) and noncharged catheters (84.7%, P = ns). In contrast, the thickness of surface clot coverage for positively charged catheters was 87.5%, compared with 28.45% (P= 0.03) for noncharged catheters and 11.25% (P = 0.03) for negatively charged catheters, compared with noncharged catheters. We describe a novel method of placing negative charge on electrodes during ablation that reduced coagulum formation. This may decrease thromboembolism-related complications with radiofrequency ablation procedures.

  17. Toward magnetic resonance-guided electroanatomical voltage mapping for catheter ablation of scar-related ventricular tachycardia: a comparison of registration methods.

    PubMed

    Tao, Qian; Milles, Julien; VAN Huls VAN Taxis, Carine; Lamb, Hildo J; Reiber, Johan H C; Zeppenfeld, Katja; VAN DER Geest, Rob J

    2012-01-01

    Integration of preprocedural delayed enhanced magnetic resonance imaging (DE-MRI) with electroanatomical voltage mapping (EAVM) may provide additional high-resolution substrate information for catheter ablation of scar-related ventricular tachycardias (VT). Accurate and fast image integration of DE-MRI with EAVM is desirable for MR-guided ablation. Twenty-six VT patients with large transmural scar underwent catheter ablation and preprocedural DE-MRI. With different registration models and EAVM input, 3 image integration methods were evaluated and compared to the commercial registration module CartoMerge. The performance was evaluated both in terms of distance measure that describes surface matching, and correlation measure that describes actual scar correspondence. Compared to CartoMerge, the method that uses the translation-and-rotation model and high-density EAVM input resulted in a registration error of 4.32±0.69 mm as compared to 4.84 ± 1.07 (P <0.05); the method that uses the translation model and high-density EAVM input resulted in a registration error of 4.60 ± 0.65 mm (P = NS); and the method that uses the translation model and a single anatomical landmark input resulted in a registration error of 6.58 ± 1.63 mm (P < 0.05). No significant difference in scar correlation was observed between all 3 methods and CartoMerge (P = NS). During VT ablation procedures, accurate integration of EAVM and DE-MRI can be achieved using a translation registration model and a single anatomical landmark. This model allows for image integration in minimal mapping time and is likely to reduce fluoroscopy time and increase procedure efficacy. © 2011 Wiley Periodicals, Inc.

  18. Prospective study of atrial fibrillation termination during ablation guided by automated detection of fractionated electrograms.

    PubMed

    Porter, Michael; Spear, William; Akar, Joseph G; Helms, Ray; Brysiewicz, Neil; Santucci, Peter; Wilber, David J

    2008-06-01

    Complex fractionated atrial electrograms (CFAE) may identify critical sites for perpetuation of atrial fibrillation (AF) and provide useful targets for ablation. Current assessment of CFAE is subjective; automated detection algorithms may improve reproducibility, but their utility in guiding ablation has not been tested. In 67 patients presenting for initial AF ablation (42 paroxysmal, 25 persistent), LA and CS mapping were performed during induced or spontaneous AF. CFAE were identified by an online automated computer algorithm and displayed on electroanatomical maps. A mean of 28 +/- 18 sites/patient were identified (20 +/- 13% of mapped sites), and were more frequent during persistent AF. CFAE occurred most commonly within the CS, on the atrial septum, and around the pulmonary veins. Ablation initially targeting CFAE terminated AF in 88% of paroxysmal AF, but only 20% of persistent AF (P < 0.001). Subsequently, additional ablation was performed in all patients (PV isolation for paroxysmal AF, PV isolation + mitral and roof lines for persistent AF). Minimum follow-up was 1 year. One-year freedom from recurrent atrial arrhythmias without antiarrhythmic drug therapy after a single procedure was 90% for paroxysmal AF, and 68% for persistent AF. Ablation guided by automated detection of CFAE proved feasible, and was associated with a high AF termination rate in paroxysmal, but not persistent AF. As an adjunct to conventional techniques, it was associated with excellent long-term single procedure outcomes in both groups. Criteria for identifying optimal CFAE sites for ablation, and selection of patients most likely to benefit, require additional study.

  19. Electrophysiology testing and catheter ablation are helpful when evaluating asymptomatic patients with Wolff-Parkinson-White pattern: the con perspective.

    PubMed

    Skanes, Allan C; Obeyesekere, Manoj; Klein, George J

    2015-09-01

    The association between asymptomatic Wolff-Parkinson-White (WPW) syndrome and sudden cardiac death (SCD) has been well documented. The inherent properties of the accessory pathway determine the risk of SCD in WPW, and catheter ablation essentially eliminates this risk. An approach to WPW syndrome is needed that incorporates the patient's individualized considerations into the decision making. Patients must understand that there is a trade-off of a small immediate risk of an invasive approach for elimination of a small lifetime risk of the natural history of asymptomatic WPW. Clinicians can minimize the invasive risk by only performing ablation for patients with at-risk pathways. Copyright © 2015 Elsevier Inc. All rights reserved.

  20. Retrieval of a detached transseptal sheath tip from a right pulmonary artery branch following catheter ablation.

    PubMed

    Schricker, Amir A; Feld, Gregory K; Tsimikas, Sotirios

    2015-11-15

    Transseptal introducer sheaths are being used with increasing frequency for left-sided arrhythmia ablations and structural heart disease interventions. Sheath tip detachment and embolization is an uncommon but known complication, and several sheaths have been recalled due to such complications. We report a unique case of a fractured transseptal sheath tip that embolized to a branch of the right pulmonary artery in a patient who had undergone ablation of a left-sided atypical atrial flutter. During final removal of one of the two long 8.5-French SL1 transseptal sheaths used routinely as part of the ablation, the radiopaque tip of the sheath fractured and first embolized to the right atrium and subsequently to a secondary right pulmonary artery branch. Using techniques derived from percutaneous interventional approaches, including a multipurpose catheter, coronary guidewire, and monorail angioplasty balloon, the sheath tip was successfully wired through its inner lumen, trapped from the inside with the balloon, and removed from the body via a large femoral vein sheath, without complications. The approach detailed in this case may guide future cases and circumvent urgent surgical intervention. © 2015 Wiley Periodicals, Inc.

  1. Venous hemostasis postcatheter ablation of atrial fibrillation while under therapeutic levels of oral and intravenous anticoagulation.

    PubMed

    Issa, Ziad F; Amr, Bashar S

    2015-11-01

    Catheter ablation of atrial fibrillation (AF) requires utilizing multiple venous femoral sheaths in conjunction with aggressive periprocedural anticoagulation, which can lead to increased risk of vascular access complications. The objective of this study is to evaluate the safety and efficacy of the "figure-of-eight" ("F-8") suture technique for femoral venous hemostasis while on therapeutic doses of intravenous anticoagulation at the time of sheath removal. In this case-control analysis, 376 consecutive patients underwent AF ablation while on uninterrupted oral anticoagulation and received intraprocedural heparin. In the first 253 patients (the control group), manual pressure was used for femoral venous hemostasis after reversal of heparin effects. The subsequent 123 patients (the F-8 group) had femoral venous hemostasis using the F-8 suture technique and while under therapeutic heparin effects. The F-8 subcutaneous suture technique achieved adequate venous hemostasis in 98.4% of patients. As compared to the control group, there was significantly less frequent utilization of the FemoStop compression assist device (1.2 vs. 16.8%, p < 0.0001) and in a significantly shorter interval (6.8 ± 5.7 vs. 50.7 ± 12.2 min, p < 0.0001). Vascular access complications and thromboembolic events occurred in 9.8% in the F-8 group vs. 13.0% in the control group (p = 0.678). Immediate hemostasis of the femoral venous access sites after insertion of multiple sheaths for AF ablation in the presence of anticoagulation can be safely and effectively achieved using the F-8 suture technique. This technique helps minimize the period of inadequate anticoagulation immediately following ablation and shortens the time required to achieve adequate hemostasis.

  2. Comparison of health-related quality of life in patients with atrial fibrillation treated with catheter ablation or antiarrhythmic drug therapy: a systematic review and meta-analysis protocol.

    PubMed

    Allan, Katherine S; Henry, Shaunattonie; Aves, Theresa; Banfield, Laura; Victor, J Charles; Dorian, Paul; Healey, Jeff S; Andrade, Jason; Carroll, Sandra; McGillion, Michael

    2017-08-21

    Atrial fibrillation (AF) is the most prevalent cardiac arrhythmia and causes patients considerable burden; symptoms such as palpitations and dyspnoea are common, leading to frequent emergency room visits. Patients with AF report reduced health-related quality of life (HQOL) compared with the general population; thus, treatments focus on the restoration of sinus rhythm to improve symptoms. Catheter ablation (CA) is a primary treatment strategy to treat AF-related burden in select patient populations; however, repeat procedures are often needed, there is a risk of major complications and the procedure is quite costly in comparison to medical therapy. As the outcomes after CA are mixed, an updated review that synthesises the available literature, on outcomes that matter to patients, is needed so that patients and their healthcare providers can make quality treatment decisions. The purpose of this review protocol is to extend previous findings by systematically analysing randomised controlled trials (RCTs) of CA in patients with AF and using meta-analytic techniques to identify the benefits and risks of CA with respect to HQOL and AF-related symptoms. We will include all RCTs that compare CA with antiarrhythmic drugs, or radiofrequency CA with cryoballoon CA, in patients with paroxysmal or persistent AF. To locate studies we will perform comprehensive electronic database searches from database inception to 4 April 2017, with no language restrictions. We will conduct a quantitative synthesis of the effect of CA on HQOL as well as AF-related symptoms and the number of CA procedures needed for success, using meta-analytic techniques. No ethical issues are foreseen and ethical approval is not required given that this is a protocol. The findings of the study will be reported at national and international conferences, and in a peer-reviewed journal using the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. In accordance with the

  3. Endo-epicardial ablation of ventricular arrhythmias in the left ventricle with the Remote Magnetic Navigation System and the 3.5-mm open irrigated magnetic catheter: results from a large single-center case-control series.

    PubMed

    Di Biase, Luigi; Santangeli, Pasquale; Astudillo, Vladimir; Conti, Sergio; Mohanty, Prasant; Mohanty, Sanghamitra; Sanchez, Javier E; Horton, Rodney; Thomas, Barbara; Burkhardt, J David; Natale, Andrea

    2010-08-01

    Remote magnetic navigation (RMN) has been reported as a feasible and safe mapping and ablation system for treatment of ventricular arrhythmias (VAs). However, the reported success rates have been limited with the 4- and 8-mm catheter tips. This study sought to report the results in a large series of consecutive patients undergoing radiofrequency (RF) catheter ablation of VAs using the RMN with the 3.5-mm magnetic open-irrigated-tip catheter (OIC). A total of 110 consecutive patients with a clinical history of left VA were included in the study. In all cases, an OIC was utilized for mapping and ablation. When ablation with the RMN catheters failed, a manual OIC was used to eliminate the VA. Postablation pacing maneuvers and isoproterenol were used to verify the inducibility of the VAs. Outcomes were compared with those of a group of 92 consecutive patients undergoing manual ablation by the same operator. Mapping and ablation with the magnetic OIC were performed in all 110 patients with VA. Ischemic cardiomyopathy was present in 33 (30%), nonischemic in 14 (13%), and in 63 (57%) patients no structural heart disease was present. Endocardial mapping was performed in all patients, whereas both endocardial and epicardial mapping were performed in 36 (33%) patients. Compared with manual ablation, RMN was associated with a longer procedural time (2.9 +/- 1.2 hours vs. 3.3 +/- 1.1 hours, P = 0.004) and RF time (24 +/- 12 minutes vs. 33 +/- 18 minutes, P = 0.005), whereas fluoroscopic time was significantly shorter (35 +/- 22 minutes vs. 26 +/- 14 minutes, P = 0.033). During the procedures, crossover to manual ablation was required in 15 patients (14%). At 11.7 +/- 2.1 months of follow-up in the study group and 18.7 +/- 3.7 months in the manual ablation group, 85% and 86% (P = 0.817) of patients, respectively, were free of VA. This large series of consecutive patients demonstrates that OIC ablation using RMN is effective for the treatment of left VAs. Copyright 2010 Heart

  4. MEMS-Based Flexible Force Sensor for Tri-Axial Catheter Contact Force Measurement

    PubMed Central

    Sheng, Jun; Desai, Jaydev P.

    2016-01-01

    Atrial fibrillation (AFib) is a significant healthcare problem caused by the uneven and rapid discharge of electrical signals from pulmonary veins (PVs). The technique of radiofrequency (RF) ablation can block these abnormal electrical signals by ablating myocardial sleeves inside PVs. Catheter contact force measurement during RF ablation can reduce the rate of AFib recurrence, since it helps to determine effective contact of the catheter with the tissue, thereby resulting in effective power delivery for ablation. This paper presents the development of a three-dimensional (3D) force sensor to provide the real-time measurement of tri-axial catheter contact force. The 3D force sensor consists of a plastic cubic bead and five flexible force sensors. Each flexible force sensor was made of a PEDOT:PSS strain gauge and a PDMS bump on a flexible PDMS substrate. Calibration results show that the fabricated sensor has a linear response in the force range required for RF ablation. To evaluate its working performance, the fabricated sensor was pressed against gelatin tissue by a micromanipulator and also integrated on a catheter tip to test it within deionized water flow. Both experiments simulated the ventricular environment and proved the validity of applying the 3D force sensor in RF ablation. PMID:28190945

  5. Assessment of atrial electromechanical interval using echocardiography after catheter ablation in patients with persistent atrial fibrillation

    PubMed Central

    Chen, Xiaodong; Chen, Minglong; Wang, Yingying; Yang, Bing; Ju, Weizhu; Zhang, Fengxiang; Cao, Kejiang

    2016-01-01

    Abstract We sought to investigate variation of atrial electromechanical interval after catheter ablation procedure in patients with persistent atrial fibrillation using pulse Doppler (PW) and pulse tissue Doppler imaging (PW-TDI). A total of 25 consecutive in-patients with persistent atrial fibrillation, who restored sinus rhythm after ablation procedure, were recruited in our cardiac center. Echocardiography was performed on each patient at 2 hours, 1 day, 5 days, 1 month and 3 months after the ablation therapy, and atrial electromechanical delay was measured simultaneously by PW and PW-TDI. There was no significant difference between PW and TDI in measuring atrial electromechanical delay. However, at postoperative 2 hours, peak A detection rates were mathematically but nonsignificantly greater by PW-TDI than by PW. Second, there was a significant decreasing trend in atrial electromechanical interval from postoperative 2 hours to 3 months, but only postoperative 2-hour atrial electromechanical interval was significantly greater than atrial electromechanical interval at other time. Lastly, patients without postoperative 2-hour atrial electromechanical interval had a significantly longer duration of atrial fibrillation as compared to those with postoperative 2-hour atrial electromechanical interval, by the PW or by PW-TDI, respectively. In patients with persistent atrial fibrillation, atrial electromechanical interval may decrease significantly within the first 24 hours after ablation but remain consistent later, and was significantly related to patients’ duration of atrial fibrillation. Atrial electromechanical interval, as a potential predicted factor, is recommended to be measured by either PW or TDI after 24 hours, when patients had recovered sinus rhythm by radiofrequency ablation. PMID:27924066

  6. Ventricular fibrillation occurring after atrioventricular node ablation despite minimal difference between pre- and post-ablation heart rates.

    PubMed

    Squara, F; Theodore, G; Scarlatti, D; Ferrari, E

    2017-02-01

    We report the case of an 82-year-old man presenting with ventricular fibrillation (VF) occurring acutely after atrioventricular node (AVN) ablation. This patient had severe valvular cardiomyopathy, chronic atrial fibrillation (AF), and underwent prior to the AVN ablation a biventricular implantable cardiac defibrillator positioning. The VF was successfully cardioverted with one external electrical shock. What makes this presentation original is that the pre-ablation spontaneous heart rate in AF was slow (84 bpm), and that VF occurred after ablation despite a minimal heart rate drop of only 14 bpm. VF is the most feared complication of AVN ablation, but it had previously only been described in case of acute heart rate drop after ablation of at least 30 bpm (and more frequently>50 bpm). This case report highlights the fact that VF may occur after AVN ablation regardless of the heart rate drop, rendering temporary fast ventricular pacing mandatory whatever the pre-ablation heart rate. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  7. Termination of persistent atrial fibrillation during pulmonary vein isolation: insight from the MAGIC-AF trial.

    PubMed

    Singh, Sheldon M; d'Avila, Andre; Kim, Young-Hoon; Aryana, Arash; Mangrum, J Michael; Michaud, Gregory F; Dukkipati, Srinivas R; Barrett, Conor D; Heist, E Kevin; Parides, Michael K; Thorpe, Kevin E; Reddy, Vivek Y

    2017-10-01

    Controversy on the optimal ablation strategy for persistent atrial fibrillation (AF) exists with limited work evaluating a strategy of pulmonary vein isolation (PVI) alone when AF terminates during PVI. Thirty-five patients had AF termination during PVI in the Modified Ablation Guided by Ibutilide Use in Chronic Atrial Fibrillation (MAGIC-AF; ClinicalTrials.gov number: NCT01014741) study. The objective of the current study is to report the 1-year outcome after PVI alone in this unique patient group. The 1-year single procedure freedom from atrial arrhythmia off anti-arrhythmic drugs was reported for the 35 patients in the MAGIC-AF study with persistent AF termination during or upon completion of PVI. Freedom from recurrent atrial arrhythmia was achieved in 60% of patients where AF terminated during PVI. Cavotricuspid isthmus flutter was common when AF terminated to a macro re-entrant flutter during PVI, and responsible for 92% of all flutter circuits with AF termination. Persistent AF termination during PVI may identify a subgroup of patients who experience a similar long-term clinical outcome with PVI ablation alone when compared with other more extensive persistent AF ablation strategies. Pulmonary vein isolation alone may be an appropriate tactic in this subgroup of persistent AF patients. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2016. For permissions please email: journals.permissions@oup.com.

  8. Clinical impact of rotor ablation in atrial fibrillation: a systematic review.

    PubMed

    Parameswaran, Ramanathan; Voskoboinik, Aleksandr; Gorelik, Alexandra; Lee, Geoffrey; Kistler, Peter M; Sanders, Prashanthan; Kalman, Jonathan M

    2018-01-11

    Rotor mapping and ablation have gained favour over the recent years as an emerging ablation strategy targeting drivers of atrial fibrillation (AF). Their efficacy, however, has been a topic of great debate with variable outcomes across centres. The aim of this study was to systematically review the recent medical literature to determine the medium-term outcomes of rotor ablation in patients with paroxysmal atrial fibrillation (PAF) and persistent atrial fibrillation (PeAF). A systematic search of the contemporary scientific literature (PubMed and EMBASE) was performed in August 2017. Only studies assessing arrhythmia-free survival from rotor ablation of AF were included. We used the random-effects model to assess the primary outcome of pooled medium-term single-procedure AF-free survival for both PAF and PeAF. Success rates from multiple procedures and complication rates were also examined. We included 11 observational studies (4 PAF and 10 PeAF) with a total of 556 patients (166 PAF and 390 PeAF). Pooled single-procedure freedom from AF was 37.8% [95% confidence interval 5.6-86.3%] at a mean follow-up period of 13.8 ± 1.8 months for PAF and 59.2% (95% CI 41.4-74.9%) at a mean follow-up period of 12.9 ± 6 months for PeAF. There was a marked heterogeneity between studies (I2 = 93.8% for PAF and 88.3% for PeAF). The mean complication rate of rotor ablation among the reported studies was 3.4%. The wide variability in success rate between different centres performing rotor ablations suggests that the optimal ablation strategy, particularly targeting rotors, is unclear. Results from randomized studies are necessary before this technique can be considered as an established clinical tool. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author(s) 2018. For permissions, please email: journals.permissions@oup.com.

  9. Reduction in radiation dose for atrial fibrillation ablation over time: A 12-year single-center experience of 2344 patients.

    PubMed

    Voskoboinik, Aleksandr; Kalman, Elana S; Savicky, Yonatan; Sparks, Paul B; Morton, Joseph B; Lee, Geoffrey; Kistler, Peter M; Kalman, Jonathan M

    2017-06-01

    Pulmonary vein isolation (PVI) is a well-established treatment of atrial fibrillation (AF), with contact force (CF)-sensing catheters joining 3-dimensional mapping systems and image integration as technological advancements over the last decade. The purpose of this study was to analyze trends in radiation exposure for AF ablation over the last 12 years at our center. We reviewed prospectively collected data of 2344 consecutive PVI procedures for either paroxysmal or persistent AF between January 2004 and December 2015. During this period, all cases used 3-dimensional mapping systems, with 8 software and 2 hardware upgrades. Primary endpoints were fluoroscopy time, absorbed dose (Air Kerma in mGy), and effective dose (mSv). In total, 1914 patients underwent initial PVI, and 430 patients underwent redo PVI using radiofrequency energy. Fluoroscopy time, and absorbed and effective doses significantly and progressively decreased over the 12-year period for initial PVI as follows: 2004-2006: 61 ± 27 minutes; 2007-2009: 46 ± 14 minutes, 1365 ± 1369 mGy, 11.3 ± 12.5 mSv; 2010-2012: 31 ± 11, 464 ± 339 mGy, 9.0 ± 10.4 mSv; and 2013-2015: 17 ± 9 minutes, 304 ± 758 mGy, 5.5 ± 6.7 mSv. CF-sensing catheters were used for 357/508 PVI only cases between 2014 and 2015. Fluoroscopy times (11 ± 5 vs 21 ± 8 minutes; P <.001) and absorbed dose (200 ± 524 vs 470 ± 1326 mGy; P = .004) were significantly shorter with this catheter. Radiation exposure has dramatically decreased over the last decade for PVI and is related to operator experience, annual case volume, technology evolution, and more recently CF-sensing catheters. This has significant implications for both patient and operator long-term risk. Copyright © 2017 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  10. The best of two worlds? Pulmonary vein isolation using a novel radiofrequency ablation catheter incorporating contact force sensing technology and 56-hole porous tip irrigation.

    PubMed

    Maurer, Tilman; Rottner, Laura; Makimoto, Hisaki; Reissmann, Bruno; Heeger, Christian-H; Lemes, Christine; Fink, Thomas; Riedl, Johannes; Santoro, Francesco; Wohlmuth, Peter; Volkmer, Marius; Mathew, Shibu; Metzner, Andreas; Ouyang, Feifan; Kuck, Karl-Heinz; Sohns, Christian

    2018-05-08

    This study aimed to evaluate feasibility and safety as well as 1-year clinical outcome of pulmonary vein isolation (PVI) using a unique radiofrequency ablation catheter ("Thermocool SmartTouch SurroundFlow"; STSF) incorporating both, contact force (CF) sensing technology and enhanced tip irrigation with 56 holes, in one device. A total of 110 patients suffering from drug-refractory atrial fibrillation underwent wide area circumferential PVI using either the STSF ablation catheter (75 consecutive patients, study group) or a CF catheter with conventional tip irrigation ("Thermocool SmartTouch", 35 consecutive patients, control group). For each ablation lesion, a target CF of ≥ 10-39 g and a force time integral (FTI) of > 400 g s was targeted. Acute PVI was achieved in all patients with target CF obtained in > 85% of ablation points when using either device. Mean procedure time (131.3 ± 33.7 min in the study group vs. 133.0 ± 42.0 min in the control group; p = 0.99), mean fluoroscopy time (14.0 ± 6 vs. 13.5 ± 6.6 min; p = 0.56) and total ablation time were not significantly different (1751.0 ± 394.0 vs. 1604.6 ± 287.8 s; p = 0.2). However, there was a marked reduction in total irrigation fluid delivery by 51.7% (265.52 ± 64.4 vs. 539.6 ± 118.2 ml; p < 0.01). The Kaplan-Meier estimate 12-month arrhythmia-free survival after the index procedure following a 3-month blanking period was 79.9% (95% CI 70.4%, 90.4%) for the study group and 66.7% for the control group (95% CI 50.2%, 88.5%). This finding did not reach statistical significance (p = 0.18). Major complications occurred in 2/75 patients (2.7%; one pericardial tamponade and one transient ischemic attack) in the study group and no patient in the control group (p = 18). PVI using the STSF catheter is safe and effective and results in beneficial 1-year clinical outcome. The improved tip irrigation leads to a significant reduction in

  11. Remote navigation systems in electrophysiology.

    PubMed

    Schmidt, Boris; Chun, Kyoung Ryul Julian; Tilz, Roland R; Koektuerk, Buelent; Ouyang, Feifan; Kuck, Karl-Heinz

    2008-11-01

    Today, atrial fibrillation (AF) is the dominant indication for catheter ablation in big electrophysiologists (EP) centres. AF ablation strategies are complex and technically challenging. Therefore, it would be desirable that technical innovations pursue the goal to improve catheter stability to increase the procedural success and most importantly to increase safety by helping to avoid serious complications. The most promising technical innovation aiming at the aforementioned goals is remote catheter navigation and ablation. To date, two different systems, the NIOBE magnetic navigation system (MNS, Stereotaxis, USA) and the Sensei robotic navigation system (RNS, Hansen Medical, USA), are commercially available. The following review will introduce the basic principles of the systems, will give an insight into the merits and demerits of remote navigation, and will further focus on the initial clinical experience at our centre with focus on pulmonary vein isolation (PVI) procedures.

  12. Considerations for theoretical modeling of thermal ablation with catheter-based ultrasonic sources: implications for treatment planning, monitoring and control

    PubMed Central

    Prakash, Punit; Diederich, Chris J.

    2012-01-01

    Purpose To determine the impact of including dynamic changes in tissue physical properties during heating on feedback controlled thermal ablation with catheter-based ultrasound. Additionally, we compared impact several indicators of thermal damage on predicted extents of ablation zones for planning and monitoring ablations with this modality. Methods A 3D model of ultrasound ablation with interstitial and transurethral applicators incorporating temperature based feedback control was used to simulate thermal ablations in prostate and liver tissue. We investigated five coupled models of heat dependent changes in tissue acoustic attenuation/absorption and blood perfusion of varying degrees of complexity.. Dimensions of the ablation zone were computed using temperature, thermal dose, and Arrhenius thermal damage indicators of coagulative necrosis. A comparison of the predictions by each of these models was illustrated on a patient-specific anatomy in the treatment planning setting. Results Models including dynamic changes in blood perfusion and acoustic attenuation as a function of thermal dose/damage predicted near-identical ablation zone volumes (maximum variation < 2.5%). Accounting for dynamic acoustic attenuation appeared to play a critical role in estimating ablation zone size, as models using constant values for acoustic attenuation predicted ablation zone volumes up to 50% larger or 47% smaller in liver and prostate tissue, respectively. Thermal dose (t43 ≥ 240min) and thermal damage (Ω ≥ 4.6) thresholds for coagulative necrosis are in good agreement for all heating durations, temperature thresholds in the range of 54 °C for short (< 5 min) duration ablations and 50 °C for long (15 min) ablations may serve as surrogates for determination of the outer treatment boundary. Conclusions Accounting for dynamic changes in acoustic attenuation/absorption appeared to play a critical role in predicted extents of ablation zones. For typical 5—15 min ablations

  13. [Magnetic navigation for ablation of cardiac arrhythmias].

    PubMed

    Chen, Jian; Hoff, Per Ivar; Solheim, Eivind; Schuster, Peter; Off, Morten Kristian; Ohm, Ole-Jørgen

    2010-08-12

    The first use of magnetic navigation for radiofrequency ablation of supraventricular tachycardias, was published in 2004. Subsequently, the method has been used for treatment of most types of tachyarrhythmias. This paper provides an overview of the method, with special emphasis on usefulness of a new remote-controlled magnetic navigation system. The paper is based on our own scientific experience and literature identified through a non-systematic search in PubMed. The magnetic navigation system consists of two external electromagnets (to be placed on opposite sides of the patient), which guide an ablation catheter (with a small magnet at the tip of the catheter) to the target area in the heart. The accuracy of this procedure is higher than that with manual navigation. Personnel can be quickly trained to use remote magnetic navigation, but the procedure itself is time-consuming, particularly for patients with atrial fibrillation. The major advantage is a considerably lower radiation burden to both patient and operator, in some studies more than 50 %, and a corresponding reduction in physical strain on the operator. The incidence of procedure-related complications seems to be lower than that observed with use of manually operated ablation catheters. Work is ongoing to improve magnetic ablation catheters and methods that can simplify mapping procedures and improve efficacy of arrhythmia ablation. The basic cost for installing a complete magnetic navigation laboratory may be three times that of a conventional electrophysiological laboratory. The new magnetic navigation system has proved to be applicable during ablation for a variety of tachyarrhythmias, but is still under development.

  14. An E/e' ratio on echocardiography predicts the existence of left atrial low-voltage areas and poor outcomes after catheter ablation for atrial fibrillation.

    PubMed

    Masuda, Masaharu; Fujita, Masashi; Iida, Osamu; Okamoto, Shin; Ishihara, Takayuki; Nanto, Kiyonori; Kanda, Takashi; Sunaga, Akihiro; Tsujimura, Takuya; Matsuda, Yasuhiro; Ohashi, Takuya; Uematsu, Masaaki

    2018-05-01

    An elevated left atrial pressure has been reported to play an important role in the development of atrial remodelling in atrial fibrillation (AF) patients. The study aimed at elucidating the association between the diastolic early transmitral flow velocity/mitral annular velocity (E/e', a non-invasive surrogate of left atrial pressure) and left atrial low-voltage-area existence, and the prognostic impact of the E/e' on procedural outcomes in patients undergoing AF ablation. Total of 215 consecutive patients were divided into 3 groups based on the estimated left atrial pressure: normal (E/e' < 8.0, n = 58), undetermined (E/e' = 8.0-14.0, n = 114), and elevated (E/e' > 14.0, n = 43). Left atrial endocardial voltage mapping was performed following pulmonary vein isolation. Patients with a high E/e' more frequently had low-voltage areas (E/e' < 8.0, 31%, E/e' = 8.0-14.0, 35%; E/e' > 14.0, 67%; P = 0.0001). After adjusting for other correlates, a high E/e' was an independent predictor of low-voltage-area existence (HR = 1.11, 95% CI = 1.02-1.21, P = 0.017). During a mean follow-up period of 12 ± 6 months, recurrent atrial tachyarrhythmias occurred in 22 (10%) patients after multiple (1.4 ± 0.5) procedures. Patients with an E/e' > 14 had more frequent recurrent atrial tachyarrhythmias after multiple ablation procedures than those with an E/e' ≤ 14 (23% vs. 7%, P = 0.001). A high E/e' obtained by pre-ablation echocardiography was associated with a left atrial arrhythmogenic substrate in patients undergoing AF ablation. Furthermore, a high E/e' predicted poor procedural outcomes after pulmonary vein isolation.

  15. Renal sympathetic denervation using an externally irrigated radiofrequency ablation catheter for treatment of resistant hypertension - Acute safety and short term efficacy.

    PubMed

    Yalagudri, Sachin; Raju, Narayana; Das, Bharati; Daware, Ashwin; Maiya, Shreesha; Jothiraj, Kannan; Ravikishore, A G

    2015-01-01

    This study was conducted to assess the acute safety and short term efficacy of renal sympathetic denervation (RSDN) using solid tip radiofrequency ablation (RFA) catheter and saline irrigation through the renal guiding catheter to achieve effective denervation. RSDN using a specialized solid-tip RFA catheter has recently been demonstrated to safely reduce systemic blood pressure in patients with refractory hypertension, the limitation being inadequate power delivery in renal arteries. So, we used solid-tip RFA catheter along with saline irrigation for RSDN. Nine patients with resistant hypertension underwent CT and conventional renal angiography, followed by bilateral or unilateral RSDN using 5F RFA catheter with saline irrigation through renal guiding catheter. Repeat renal angiography was performed at the end of the procedure. In all patients, pre- and post-procedure serum creatinine was measured. Over 1-month period: 1) the systolic/diastolic blood pressure decreased by -57 ± 20/-25 ± 7.5 mm Hg; 2) all patients experienced a decrease in systolic blood pressure of at least -36 mm Hg (range 36-98 mm Hg); 3) there was no evidence of renal artery injury immediate post-procedure. There was no significant change in serum creatinine level. This data shows the acute procedural safety and short term efficacy of RSDN using modified externally irrigated solid tip RFA catheter. Copyright © 2015 Cardiological Society of India. Published by Elsevier B.V. All rights reserved.

  16. Catheter radiofrequency ablation for arrhythmias under the guidance of the Carto 3 three-dimensional mapping system in an operating room without digital subtraction angiography.

    PubMed

    Huang, Xingfu; Chen, Yanjia; Huang, Zheng; He, Liwei; Liu, Shenrong; Deng, Xiaojiang; Wang, Yongsheng; Li, Rucheng; Xu, Dingli; Peng, Jian

    2018-06-01

    Several studies have reported the efficacy of a zero-fluoroscopy approach for catheter radiofrequency ablation of arrhythmias in a digital subtraction angiography (DSA) room. However, no reports are available on the ablation of arrhythmias in the absence of DSA in the operating room. To investigate the efficacy and safety of catheter radiofrequency ablation for arrhythmias under the guidance of a Carto 3 three-dimensional (3D) mapping system in an operating room without DSA. Patients were enrolled according to the type of arrhythmia. The Carto 3 mapping system was used to reconstruct heart models and guide the electrophysiologic examination, mapping, and ablation. The total procedure, reconstruction, electrophysiologic examination, and mapping times were recorded. Furthermore, immediate success rates and complications were also recorded. A total of 20 patients were enrolled, including 12 males. The average age was 51.3 ± 17.2 (19-76) years. Nine cases of atrioventricular nodal re-entrant tachycardia, 7 cases of frequent ventricular premature contractions, 3 cases of Wolff-Parkinson-White syndrome, and 1 case of typical atrial flutter were included. All arrhythmias were successfully ablated. The procedure time was 127.0 ± 21.0 (99-177) minutes, the reconstruction time was 6.5 ± 2.9 (3-14) minutes, the electrophysiologic study time was 10.4 ± 3.4 (6-20) minutes, and the mapping time was 11.7 ± 8.3 (3-36) minutes. No complications occurred. Radiofrequency ablation of arrhythmias without DSA is effective and feasible under the guidance of the Carto 3 mapping system. However, the electrophysiology physician must have sufficient experience, and related emergency measures must be present to ensure safety.

  17. Assessment of atrial electromechanical interval using echocardiography after catheter ablation in patients with persistent atrial fibrillation.

    PubMed

    Chen, Xiaodong; Chen, Minglong; Wang, Yingying; Yang, Bing; Ju, Weizhu; Zhang, Fengxiang; Cao, Kejiang

    2016-11-01

    We sought to investigate variation of atrial electromechanical interval after catheter ablation procedure in patients with persistent atrial fibrillation using pulse Doppler (PW) and pulse tissue Doppler imaging (PW-TDI). A total of 25 consecutive in-patients with persistent atrial fibrillation, who restored sinus rhythm after ablation procedure, were recruited in our cardiac center. Echocardiography was performed on each patient at 2 hours, 1 day, 5 days, 1 month and 3 months after the ablation therapy, and atrial electromechanical delay was measured simultaneously by PW and PW-TDI. There was no significant difference between PW and TDI in measuring atrial electromechanical delay. However, at postoperative 2 hours, peak A detection rates were mathematically but nonsignificantly greater by PW-TDI than by PW. Second, there was a significant decreasing trend in atrial electromechanical interval from postoperative 2 hours to 3 months, but only postoperative 2-hour atrial electromechanical interval was significantly greater than atrial electromechanical interval at other time. Lastly, patients without postoperative 2-hour atrial electromechanical interval had a significantly longer duration of atrial fibrillation as compared to those with postoperative 2-hour atrial electromechanical interval, by the PW or by PW-TDI, respectively. In patients with persistent atrial fibrillation, atrial electromechanical interval may decrease significantly within the first 24 hours after ablation but remain consistent later, and was significantly related to patients' duration of atrial fibrillation. Atrial electromechanical interval, as a potential predicted factor, is recommended to be measured by either PW or TDI after 24 hours, when patients had recovered sinus rhythm by radiofrequency ablation. © 2016 by the Journal of Biomedical Research. All rights reserved.

  18. Real-Time MRI-Guided Cardiac Cryo-Ablation: A Feasibility Study.

    PubMed

    Kholmovski, Eugene G; Coulombe, Nicolas; Silvernagel, Joshua; Angel, Nathan; Parker, Dennis; Macleod, Rob; Marrouche, Nassir; Ranjan, Ravi

    2016-05-01

    MRI-based ablation provides an attractive capability of seeing ablation-related tissue changes in real time. Here we describe a real-time MRI-based cardiac cryo-ablation system. Studies were performed in canine model (n = 4) using MR-compatible cryo-ablation devices built for animal use: focal cryo-catheter with 8 mm tip and 28 mm diameter cryo-balloon. The main steps of MRI-guided cardiac cryo-ablation procedure (real-time navigation, confirmation of tip-tissue contact, confirmation of vessel occlusion, real-time monitoring of a freeze zone formation, and intra-procedural assessment of lesions) were validated in a 3 Tesla clinical MRI scanner. The MRI compatible cryo-devices were advanced to the right atrium (RA) and right ventricle (RV) and their position was confirmed by real-time MRI. Specifically, contact between catheter tip and myocardium and occlusion of superior vena cava (SVC) by the balloon was visually validated. Focal cryo-lesions were created in the RV septum. Circumferential ablation of SVC-RA junction with no gaps was achieved using the cryo-balloon. Real-time visualization of freeze zone formation was achieved in all studies when lesions were successfully created. The ablations and presence of collateral damage were confirmed by T1-weighted and late gadolinium enhancement MRI and gross pathological examination. This study confirms the feasibility of a MRI-based cryo-ablation system in performing cardiac ablation procedures. The system allows real-time catheter navigation, confirmation of catheter tip-tissue contact, validation of vessel occlusion by cryo-balloon, real-time monitoring of a freeze zone formation, and intra-procedural assessment of ablations including collateral damage. © 2016 Wiley Periodicals, Inc.

  19. Force Trends and Pulsatility for Catheter Contact Identification in Intracardiac Electrograms during Arrhythmia Ablation

    PubMed Central

    Muñoz-Romero, Sergio; Erazo-Rodas, Mayra; Sánchez-Muñoz, Juan José; García-Alberola, Arcadi

    2018-01-01

    The intracardiac electrical activation maps are commonly used as a guide in the ablation of cardiac arrhythmias. The use of catheters with force sensors has been proposed in order to know if the electrode is in contact with the tissue during the registration of intracardiac electrograms (EGM). Although threshold criteria on force signals are often used to determine the catheter contact, this may be a limited criterion due to the complexity of the heart dynamics and cardiac vorticity. The present paper is devoted to determining the criteria and force signal profiles that guarantee the contact of the electrode with the tissue. In this study, we analyzed 1391 force signals and their associated EGM recorded during 2 and 8 s, respectively, in 17 patients (82 ± 60 points per patient). We aimed to establish a contact pattern by first visually examining and classifying the signals, according to their likely-contact joint profile and following the suggestions from experts in the doubtful cases. First, we used Principal Component Analysis to scrutinize the force signal dynamics by analyzing the main eigen-directions, first globally and then grouped according to the certainty of their tissue-catheter contact. Second, we used two different linear classifiers (Fisher discriminant and support vector machines) to identify the most relevant components of the previous signal models. We obtained three main types of eigenvectors, namely, pulsatile relevant, non-pulsatile relevant, and irrelevant components. The classifiers reached a moderate to sufficient discrimination capacity (areas under the curve between 0.84 and 0.95 depending on the contact certainty and on the classifier), which allowed us to analyze the relevant properties in the force signals. We conclude that the catheter-tissue contact profiles in force recordings are complex and do not depend only on the signal intensity being above a threshold at a single time instant, but also on time pulsatility and trends. These

  20. Force Trends and Pulsatility for Catheter Contact Identification in Intracardiac Electrograms during Arrhythmia Ablation.

    PubMed

    Rivas-Lalaleo, David; Muñoz-Romero, Sergio; Huerta, Mónica; Erazo-Rodas, Mayra; Sánchez-Muñoz, Juan José; Rojo-Álvarez, José Luis; García-Alberola, Arcadi

    2018-05-02

    The intracardiac electrical activation maps are commonly used as a guide in the ablation of cardiac arrhythmias. The use of catheters with force sensors has been proposed in order to know if the electrode is in contact with the tissue during the registration of intracardiac electrograms (EGM). Although threshold criteria on force signals are often used to determine the catheter contact, this may be a limited criterion due to the complexity of the heart dynamics and cardiac vorticity. The present paper is devoted to determining the criteria and force signal profiles that guarantee the contact of the electrode with the tissue. In this study, we analyzed 1391 force signals and their associated EGM recorded during 2 and 8 s, respectively, in 17 patients (82 ± 60 points per patient). We aimed to establish a contact pattern by first visually examining and classifying the signals, according to their likely-contact joint profile and following the suggestions from experts in the doubtful cases. First, we used Principal Component Analysis to scrutinize the force signal dynamics by analyzing the main eigen-directions, first globally and then grouped according to the certainty of their tissue-catheter contact. Second, we used two different linear classifiers (Fisher discriminant and support vector machines) to identify the most relevant components of the previous signal models. We obtained three main types of eigenvectors, namely, pulsatile relevant, non-pulsatile relevant, and irrelevant components. The classifiers reached a moderate to sufficient discrimination capacity (areas under the curve between 0.84 and 0.95 depending on the contact certainty and on the classifier), which allowed us to analyze the relevant properties in the force signals. We conclude that the catheter-tissue contact profiles in force recordings are complex and do not depend only on the signal intensity being above a threshold at a single time instant, but also on time pulsatility and trends

  1. Pulmonary vein region ablation in experimental vagal atrial fibrillation: role of pulmonary veins versus autonomic ganglia.

    PubMed

    Lemola, Kristina; Chartier, Denis; Yeh, Yung-Hsin; Dubuc, Marc; Cartier, Raymond; Armour, Andrew; Ting, Michael; Sakabe, Masao; Shiroshita-Takeshita, Akiko; Comtois, Philippe; Nattel, Stanley

    2008-01-29

    Pulmonary vein (PV) -encircling radiofrequency ablation frequently is effective in vagal atrial fibrillation (AF), and there is evidence that PVs may be particularly prone to cholinergically induced arrhythmia mechanisms. However, PV ablation procedures also can affect intracardiac autonomic ganglia. The present study examined the relative role of PVs versus peri-PV autonomic ganglia in an experimental vagal AF model. Cholinergic AF was studied under carbachol infusion in coronary perfused canine left atrial PV preparations in vitro and with cervical vagal stimulation in vivo. Carbachol caused dose-dependent AF promotion in vitro, which was not affected by excision of all PVs. Sustained AF could be induced easily in all dogs during vagal nerve stimulation in vivo both before and after isolation of all PVs with encircling lesions created by a bipolar radiofrequency ablation clamp device. PV elimination had no effect on atrial effective refractory period or its responses to cholinergic stimulation. Autonomic ganglia were identified by bradycardic and/or tachycardic responses to high-frequency subthreshold local stimulation. Ablation of the autonomic ganglia overlying all PV ostia suppressed the effective refractory period-abbreviating and AF-promoting effects of cervical vagal stimulation, whereas ablation of only left- or right-sided PV ostial ganglia failed to suppress AF. Dominant-frequency analysis suggested that the success of ablation in suppressing vagal AF depended on the elimination of high-frequency driver regions. Intact PVs are not needed for maintenance of experimental cholinergic AF. Ablation of the autonomic ganglia at the base of the PVs suppresses vagal responses and may contribute to the effectiveness of PV-directed ablation procedures in vagal AF.

  2. Conventional versus 3-D Echocardiography to Predict Arrhythmia Recurrence After Atrial Fibrillation Ablation.

    PubMed

    Bossard, Matthias; Knecht, Sven; Aeschbacher, Stefanie; Buechel, Ronny R; Hochgruber, Thomas; Zimmermann, Andreas J; Kessel-Schaefer, Arnheid; Stephan, Frank-Peter; Völlmin, Gian; Pradella, Maurice; Sticherling, Christian; Osswald, Stefan; Kaufmann, Beat A; Conen, David; Kühne, Michael

    2017-06-01

    Arrhythmia recurrence after atrial fibrillation (AF) ablation remains high and requires repeat interventions in a substantial number of patients. We assessed the value of conventional and 3-D echocardiography to predict AF recurrence. Consecutive patients undergoing AF ablation by means of pulmonary vein isolation were included in a prospective registry. Echocardiograms were obtained prior to the ablation procedure, and analyzed offline in a standardized manner, including 3-D left atrial (LA) volumetry and determination of LA function and sphericity. The primary endpoint, AF recurrence (>30 seconds) between 3 to 12 months after AF ablation, was independently adjudicated. We included 276 patients (73% male, mean age 59.9 ± 9.9 years). Paroxysmal and persistent AF were present in 178 (64%) and 98 (36%) patients, respectively. Mean left ventricular ejection fraction and indexed LA volume in 3-D (LAVI) were 52 ± 12% and 42 ± 13 mL/m 2 , respectively. AF recurrence was observed in 110 (40%) patients after a single procedure. Median (interquartile range) time to AF recurrence was 123 (92; 236) days. In multivariable Cox regression models, the only predictors for AF recurrence were the minimal, maximal, and indexed 3-D LA volumes, P = 0.024, P = 0.016, and P = 0.014, respectively. Quartile specific analysis of 3-D LAVI showed an HR of 1.885 (95%CI 1.066-3.334; P for trend = 0.015) for the highest compared to the lowest quartile. Our results show the important role of LA volume for the long-term freedom from arrhythmia after AF ablation. These data also highlight the potential of 3-D echocardiography in this context and may facilitate patient selection for AF ablation. © 2017 Wiley Periodicals, Inc.

  3. The burden of proof: The current state of atrial fibrillation prevention and treatment trials

    PubMed Central

    Zakeri, Rosita; Van Wagoner, David R.; Calkins, Hugh; Wong, Tom; Ross, Heather M.; Heist, E. Kevin; Meyer, Timothy E.; Kowey, Peter R.; Mentz, Robert J.; Cleland, John G.; Pitt, Bertram; Zannad, Faiez; Linde, Cecilia

    2017-01-01

    Atrial fibrillation (AF) is an age-related arrhythmia of enormous socioeconomic significance. In recent years, our understanding of the basic mechanisms that initiate and perpetuate AF has evolved rapidly, catheter ablation of AF has progressed from concept to reality, and recent studies suggest lifestyle modification may help prevent AF recurrence. Emerging developments in genetics, imaging, and informatics also present new opportunities for personalized care. However, considerable challenges remain. These include a paucity of studies examining AF prevention, modest efficacy of existing antiarrhythmic therapies, diverse ablation technologies and practice, and limited evidence to guide management of high-risk patients with multiple comorbidities. Studies examining the long-term effects of AF catheter ablation on morbidity and mortality outcomes are not yet completed. In many ways, further progress in the field is heavily contingent on the feasibility, capacity, and efficiency of clinical trials to incorporate the rapidly evolving knowledge base and to provide substantive evidence for novel AF therapeutic strategies. This review outlines the current state of AF prevention and treatment trials, including the foreseeable challenges, as discussed by a unique forum of clinical trialists, scientists, and regulatory representatives in a session endorsed by the Heart Rhythm Society at the 12th Global CardioVascular Clinical Trialists Forum in Washington, DC, December 3–5, 2015. PMID:28161513

  4. Antifungal catheter lock therapy for the management of a persistent Candida albicans bloodstream infection in an adult receiving hemodialysis.

    PubMed

    Paul DiMondi, V; Townsend, Mary L; Johnson, Melissa; Durkin, Michael

    2014-07-01

    Antifungal catheter lock therapy (AfLT) with liposomal amphotericin B has been used in the treatment of pediatric central line infections caused by Candida species; however, reports describing the use of liposomal amphotericin B lock therapy in the adult hemodialysis patient population are lacking. Management of central line-associated candidemia with systemic therapy alone is often challenging due to the propensity of Candida species to form biofilms on foreign bodies. We describe a 64-year-old woman who was receiving hemodialysis 3 times/week and was hospitalized with persistent fungemia. Despite receiving intravenous micafungin, she had multiple positive blood cultures for Candida albicans, which finally cleared after 7 days. Her double-lumen catheter was considered the most likely nidus of infection. Although catheter removal would have been preferred, this was not possible given her vasculopathy, history of multiple bloodstream infections, and lack of other available sites for vascular access. Catheter exchange was performed, and liposomal amphotericin B AfLT was administered in combination with intravenous micafungin for a total of 6 days. During this time, the patient experienced no discernible adverse effects secondary to AfLT. At discharge, AfLT was discontinued, and intravenous micafungin was changed to oral fluconazole. After 6 months of treatment, the patient remained culture negative and maintained her dialysis access. To our knowledge, this is the first case report of liposomal amphotericin B catheter lock therapy used to manage a persistent C. albicans bloodstream infection in an adult receiving hemodialysis. AfLT is a novel concept for treating catheter-associated fungal infections. Liposomal amphotericin B was chosen based on its favorable in vitro activity against Candida species biofilms in catheter lock environments. We identified several barriers to implementing AfLT, and these issues may prohibit the use of AfLT. This case report

  5. Method and apparatus for guiding ablative therapy of abnormal biological electrical excitation

    NASA Technical Reports Server (NTRS)

    Armoundas, Antonis A. (Inventor); Feldman, Andrew B. (Inventor); Sherman, Derin A. (Inventor); Cohen, Richard J. (Inventor)

    2001-01-01

    This invention involves method and apparatus for guiding ablative therapy of abnormal biological electrical excitation. In particular, it is designed for treatment of cardiac arrhythmias. In the method of this invention electrical signals are acquired from passive electrodes, and an inverse dipole method is used to identify the site of origin of an arrhytmia. The location of the tip of the ablation catheter is similarly localized from signals acquired from the passive electrodes while electrical energy is delivered to the tip of the catheter. The catheter tip is then guided to the site of origin of the arrhythmia, and ablative radio frequency energy is delivered to its tip to ablate the site.

  6. Isolation of the posterior left atrium for patients with persistent atrial fibrillation: routine adenosine challenge for dormant posterior left atrial conduction improves long-term outcome.

    PubMed

    McLellan, Alex J A; Prabhu, Sandeep; Voskoboinik, Alex; Wong, Michael C G; Walters, Tomos E; Pathik, Bhupesh; Morris, Gwilym M; Nisbet, Ashley; Lee, Geoffrey; Morton, Joseph B; Kalman, Jonathan M; Kistler, Peter M

    2017-12-01

    Catheter ablation to achieve posterior left atrial wall (PW) isolation may be performed as an adjunct to pulmonary vein isolation (PVI) in patients with persistent atrial fibrillation (AF). We aimed to determine whether routine adenosine challenge for dormant posterior wall conduction improved long-term outcome. A total of 161 patients with persistent AF (mean age 59 ± 9 years, AF duration 6 ± 5 years) underwent catheter ablation involving circumferential PVI followed by PW isolation. Posterior left atrial wall isolation was performed with a roof and inferior wall line with the endpoint of bidirectional block. In 54 patients, adenosine 15 mg was sequentially administered to assess reconnection of the pulmonary veins and PW. Sites of transient reconnection were ablated and adenosine was repeated until no further reconnection was present. Holter monitoring was performed at 6 and 12 months to assess for arrhythmia recurrence. Posterior left atrial wall isolation was successfully achieved in 91% of 161 patients (procedure duration 191 ± 49 min, mean RF time 40 ± 19 min). Adenosine-induced reconnection of the PW was demonstrated in 17%. The single procedure freedom from recurrent atrial arrhythmia was superior in the adenosine challenge group (65%) vs. no adenosine challenge (40%, P < 0.01) at a mean follow-up of 19 ± 8 months. After multiple procedures, there was significantly improved freedom from AF between patients with vs. without adenosine PW challenge (85 vs. 65%, P = 0.01). Posterior left atrial wall isolation in addition to PVI is a readily achievable ablation strategy in patients with persistent AF. Routine adenosine challenge for dormant posterior wall conduction was associated with an improvement in the success of catheter ablation for persistent AF. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2017. For permissions please email: journals.permissions@oup.com.

  7. Atriocaval Rupture After Right Atrial Isthmus Ablation for Atrial Flutter.

    PubMed

    Vloka, Caroline; Nelson, Daniel W; Wetherbee, Jule

    2016-06-01

    A patient with symptomatic typical atrial flutter (AFL) underwent right atrial isthmus ablation with an 8-mm catheter. Eight months later, his typical AFL recurred. Ten months later, he underwent a repeat right atrial isthmus ablation with an irrigated tip catheter and an 8-mm tip catheter. Six weeks after his second procedure, while performing intense sprint intervals on a treadmill, he developed an abrupt onset of chest pain, hypotension, and cardiac tamponade. He underwent emergency surgery to repair an atriocaval rupture and has done well since. Our report suggests that an association of multiple radiofrequency ablations with increased risk for delayed atriocaval rupture occurring 1 to 3 months after ablation. In conclusion, although patients generally were advised to limit exercise for 1 to 2 weeks after AFL ablation procedures in the past, it may be prudent to avoid intense exercise for at least 3 months after procedure. Copyright © 2016 Elsevier Inc. All rights reserved.

  8. Assessment of Atrial Fibrillation and Vulnerability in Patients with Wolff-Parkinson-White Syndrome Using Two-Dimensional Speckle Tracking Echocardiography

    PubMed Central

    Li, Jing-Jie; Wei, Fang; Chen, Ju-Gang; Yu, Yan-Wei; Gu, Hong-Yue; Jiang, Rui; Wu, Xiu-Li; Sun, Qian

    2014-01-01

    Purpose The aim was to assess atrial fibrillation (AF) and vulnerability in Wolff-Parkinson-White (WPW) syndrome patients using two-dimensional speckle tracking echocardiography (2D-STE). Methods All patients were examined via transthoracic echocardiography and 2D-STE in order to assess atrial function 7 days before and 10 days after RF catheter ablation. A postoperative 3-month follow-up was performed via outpatient visit or telephone calls. Results Results showed significant differences in both body mass index (BMI) and supraventricular tachycardia (SVT) duration between WPW patients and DAVNP patients (both P<0.05). Echocardiography revealed that the maximum left atrial volume (LAVmax) and the left ventricular mass index (LVMI) in diastole increased noticeably in patients with WPW compared to patients with DAVNP both before and after ablation (all P<0.05). Before ablation, there were obvious differences in the levels of SRs, SRe, and SRa from the 4-chamber view (LA) in the WPW patients group compared with patients in the DAVNP group (all P<0.05). In the AF group, there were significant differences in the levels of systolic strain rate (SRs), early diastolic strain rate (SRe), and late diastolic strain rate (SRa) from the 4-chamber view (LA) both before and after ablation (all P<0.05). In the non-AF group, there were decreased SRe levels from the 4-chamber view (LA/RA) pre-ablation compared to post-ablation (all P<0.05). Conclusion Our findings provide convincing evidence that WPW syndrome may result in increased atrial vulnerability and contribute to the development of AF. Further, RF catheter ablation of AAV pathway can potentially improve atrial function in WPW syndrome patients. Two-dimensional speckle tracking echocardiography imaging in WPW patients would be necessary in the evaluation and improvement of the overall function of RF catheter ablation in a long-term follow-up period. PMID:25397668

  9. Assessment of atrial fibrillation and vulnerability in patients with Wolff-Parkinson-White syndrome using two-dimensional speckle tracking echocardiography.

    PubMed

    Li, Jing-Jie; Wei, Fang; Chen, Ju-Gang; Yu, Yan-Wei; Gu, Hong-Yue; Jiang, Rui; Wu, Xiu-Li; Sun, Qian

    2014-01-01

    The aim was to assess atrial fibrillation (AF) and vulnerability in Wolff-Parkinson-White (WPW) syndrome patients using two-dimensional speckle tracking echocardiography (2D-STE). All patients were examined via transthoracic echocardiography and 2D-STE in order to assess atrial function 7 days before and 10 days after RF catheter ablation. A postoperative 3-month follow-up was performed via outpatient visit or telephone calls. Results showed significant differences in both body mass index (BMI) and supraventricular tachycardia (SVT) duration between WPW patients and DAVNP patients (both P<0.05). Echocardiography revealed that the maximum left atrial volume (LAVmax) and the left ventricular mass index (LVMI) in diastole increased noticeably in patients with WPW compared to patients with DAVNP both before and after ablation (all P<0.05). Before ablation, there were obvious differences in the levels of SRs, SRe, and SRa from the 4-chamber view (LA) in the WPW patients group compared with patients in the DAVNP group (all P<0.05). In the AF group, there were significant differences in the levels of systolic strain rate (SRs), early diastolic strain rate (SRe), and late diastolic strain rate (SRa) from the 4-chamber view (LA) both before and after ablation (all P<0.05). In the non-AF group, there were decreased SRe levels from the 4-chamber view (LA/RA) pre-ablation compared to post-ablation (all P<0.05). Our findings provide convincing evidence that WPW syndrome may result in increased atrial vulnerability and contribute to the development of AF. Further, RF catheter ablation of AAV pathway can potentially improve atrial function in WPW syndrome patients. Two-dimensional speckle tracking echocardiography imaging in WPW patients would be necessary in the evaluation and improvement of the overall function of RF catheter ablation in a long-term follow-up period.

  10. Left septal atrial tachycardia after open-heart surgery: relevance to surgical approach, anatomical and electrophysiological characteristics associated with catheter ablation, and procedural outcomes.

    PubMed

    Adachi, Toru; Yoshida, Kentaro; Takeyasu, Noriyuki; Masuda, Keita; Sekiguchi, Yukio; Sato, Akira; Tada, Hiroshi; Nogami, Akihiko; Aonuma, Kazutaka

    2015-02-01

    Septal atrial tachycardia (AT) can occur in patients without structural heart disease and in patients with previous catheter ablation of atrial fibrillation. We aimed to assess septal AT that occurs after open-heart surgery. This study comprised 20 consecutive patients undergoing catheter ablation of macroreentrant AT after open-heart surgery. Relevance to surgical approach, mechanisms, anatomic and electrophysiological characteristics, and outcomes were assessed. Septal AT was identified in 7 patients who had all undergone mitral valve surgery. All septal ATs were localized in the left atrial septum, whereas 10 of 13 nonseptal ATs originated from the right atrium. Patients with left septal AT had a thicker fossa ovalis (median, 4.0; 25th-75th percentile, 3.6-4.2 versus 2.3; 1.6-2.6 mm; P=0.006) and broader area of low voltage (<0.3 mV) in the septum than patients with nonseptal AT (82; 76-89 versus 31; 28%-36%; P=0.02). Repeated gradual prolongations of the tachycardia cycle length without change of the septal circuit were observed in all patients with septal AT (70; 63-100 versus 15; 10-40 ms; P=0.0008). Although ablation terminated all ATs, recurrence of targeted ATs was more frequent in patients with left septal AT during 30-month follow-up (71 versus 0%; P=0.001). Left septal AT after open-heart surgery was characterized by a thicker septum, more scar burden in the septum, and repeated prolongations of the tachycardia cycle length during ablation. Such an arrhythmogenic substrate may interfere with transmural lesion formation by ablation and may account for higher likelihood of recurrence of left septal AT. © 2014 American Heart Association, Inc.

  11. Large eccentric laser angioplasty catheter

    NASA Astrophysics Data System (ADS)

    Taylor, Kevin D.; Reiser, Christopher

    1997-05-01

    In response to recent demand for increased debulking of large diameter coronary vascular segments, a large eccentric catheter for excimer laser coronary angioplasty has been developed. The outer tip diameter is 2.0 mm and incorporates approximately 300 fibers of 50 micron diameter in a monorail- type percutaneous catheter. The basic function of the device is to ablate a coronary atherosclerotic lesion with 308 nm excimer laser pulses, while passing the tip of the catheter through the lesion. By employing multiple passes through the lesion, rotating the catheter 90 degrees after each pass, we expect to create luminal diameters close to 3 mm with this device. Design characteristics, in-vitro testing, and initial clinical experience is presented.

  12. Novel Percutaneous Epicardial Autonomic Modulation in the Canine for Atrial Fibrillation: Results of an Efficacy and Safety Study

    PubMed Central

    Madhavan, Malini; Venkatachalam, K. L.; Swale, Matthew J.; DeSimone, Christopher V.; Gard, Joseph J.; Johnson, Susan B.; Suddendorf, Scott H.; Mikell, Susan B.; Ladewig, Dorothy J.; Nosbush, Toni Grabinger; Danielsen, Andrew J.; Knudson, Mark; Asirvatham, Samuel J.

    2016-01-01

    Background Endocardial ablation of atrial ganglionated plexi (GP) has been described for treatment of atrial fibrillation (AF). Our objective in this study was to develop percutaneous epicardial GP ablation in a canine model using novel energy sources and catheters. Methods Phase 1: The efficacy of several modalities to ablate the GP was tested in an open chest canine model (n=10). Phase 2: Percutaneous epicardial ablation of GP was done in 6 dogs using the most efficacious modality identified in phase 1 using 2 novel catheters. Results Phase 1: DC in varying doses [blocking (7 -12μA), electroporation (300-500μA), ablation (3000- 7500μA)], radiofrequency ablation (25–50 W), ultrasound (1.5MHz), and alcohol (2-5ml) injection were successful at 0/8, 4/12, 5/7, 3/8, 1/5 and 5/7 GP sites. DC (500–5000μA) along with alcohol irrigation was tested in phase 2. Phase 2: Percutaneous epicardial ablation of the right atrium, oblique sinus, vein of Marshall, and transverse sinus GP was successful in 5/6 dogs. One dog died of ventricular fibrillation (VF) during DC ablation at 5000 μA. Programmed stimulation induced AF in 6 dogs pre-ablation and no atrial arrhythmia in 3, flutter in 1 and AF in 1 post-ablation. Heart rate, blood pressure, effective atrial refractory period and local atrial electrogram amplitude did not change significantly post-ablation. Microscopic examination showed elimination of GP, and minimal injury to atrial myocardium. Conclusion Percutaneous epicardial ablation of GP using direct current and novel catheters is safe and feasible and may be used as an adjunct to pulmonary vein isolation in the treatment of atrial fibrillation in order to minimize additional atrial myocardial ablation. PMID:26854009

  13. Fiber photo-catheters for laser treatment of atrial fibrillation

    PubMed Central

    Peshko, Igor; Rubtsov, Vladimir; Vesselov, Leonid; Sigal, Gennady; Laks, Hillel

    2009-01-01

    A fiber photo-catheter has been developed for surgical treatment of atrial fibrillation with laser radiation. Atrial fibrillation (AF) is a heart rhythm abnormality that involves irregular and rapid heartbeats. Recent studies demonstrate the superiority of treating AF disease with optical radiation of the near infrared region. To produce long continuous transmural lesions, solid-state lasers and laser diodes, along with end-emitting fiber catheters, have been used experimentally. The absence of side-emitting flexible catheters with the ability to produce long continuous lesions limits the further development of this technology. In this research, a prototype of an optical catheter, consisting of a flexible 10-cm fiber diffuser has been used to make continuous photocoagulation lesions for effective maze procedure treatments. The system also includes: a flexible optical reflector; a series of openings for rapid self-attachment to the tissue; and an optional closed-loop irrigating chamber with circulating saline to cool the optical diffuser and irrigate the tissue. PMID:19587838

  14. Mechanisms for the Termination of Atrial Fibrillation by Localized Ablation: Computational and Clinical Studies.

    PubMed

    Rappel, Wouter-Jan; Zaman, Junaid A B; Narayan, Sanjiv M

    2015-12-01

    Human atrial fibrillation (AF) can terminate after ablating localized regions, which supports the existence of localized rotors (spiral waves) or focal drivers. However, it is unclear why ablation near a spiral wave tip would terminate AF and not anchor reentry. We addressed this question by analyzing competing mechanisms for AF termination in numeric simulations, referenced to clinical observations. Spiral wave reentry was simulated in monodomain 2-dimensional myocyte sheets using clinically realistic rate-dependent values for repolarization and conduction. Heterogeneous models were created by introduction of parameterized variations in tissue excitability. Ablation lesions were applied as nonconducting circular regions. Models confirmed that localized ablation may anchor spiral wave reentry, producing organized tachycardias. Several mechanisms referenced to clinical observations explained termination of AF to sinus rhythm. First, lesions may create an excitable gap vulnerable to invasion by fibrillatory waves. Second, ablation of rotors in regions of low-excitability (from remodeling) produced re-entry in more excitable tissue allowing collision of wavefront and back. Conversely, ablation of rotors in high-excitability regions migrated spiral waves to less excitable tissue, where they detached to collide with nonconducting boundaries. Third, ablation may connect rotors to nonconducting anatomic orifices. Fourth, reentry through slow-conducting channels may terminate if ablation closes these channels. Limited ablation can terminate AF by several mechanisms. These data shed light on how clinical AF may be sustained in patients' atria, emphasizing heterogeneities in tissue excitability, slow-conducting channels, and obstacles that are increasingly detectable in patients and should be the focus of future translational studies. © 2015 American Heart Association, Inc.

  15. Long-term efficacy of single procedure remote magnetic catheter navigation for ablation of ischemic ventricular tachycardia: a retrospective study.

    PubMed

    Dinov, Borislav; Schönbauer, Robert; Wojdyla-Hordynska, Agnieska; Braunschweig, Frieder; Richter, Sergio; Altmann, David; Sommer, Philipp; Gaspar, Thomas; Bollmann, Andreas; Wetzel, Ulrike; Rolf, Sascha; Piorkowski, Christopher; Hindricks, Gerhard; Arya, Arash

    2012-05-01

    Remote magnetic navigation (RMN) aims to reduce some inherent limitations of manual radiofrequency (RF) ablation. However, data comparing the effectiveness of both methods are scarce. This study evaluated the acute and long-term success of RMN guided versus manual RF ablation in patients with ischemic sustained ventricular tachycardia (sVT). One hundred two consecutive patients (age 68 ± 10 years, LVEF 32 ± 12%, 88 men) with ischemic sVT were ablated with RMN (Stereotaxis; 49%) or manually (51%) using substrate and/or activation mapping (Carto) and open-irrigated-tip catheters. All received implantable defibrillators or loop recorders. Acute success was defined as noninducibility of any sVT at the end of the ablation procedure and long-term success as freedom from VT upon follow-up. There was no difference in the baseline characteristics between the groups. Three patients died in hospital. Acute success rate was similar for RMN and manual ablation (82% vs 71%, P = 0.246). RMN was associated with significantly shorter fluoroscopy time (13 ± 12 minutes vs 32 ± 17 minutes, P = 0.0001) and RF time (2337.59 ± 1248.22 seconds vs 1589.95 ± 1047.42 seconds, P = 0.049), although total procedure time was similar (157 ± 40 minutes vs 148 ± 50 minutes, P = 0.42). There was a nonsignificant trend toward better long-term success in RMN group: after a median of 13 (range 1-34) months, 63% in the RMN and 53% in the manual ablation group were free from VT recurrence (P = 0.206). RMN guided RF ablation of ischemic sustained VT is equally efficient compared with manual ablation in terms of acute and long-term success rate. These results are achieved with a significantly reduced fluoroscopy time and shorter RF time. © 2012 Wiley Periodicals, Inc.

  16. Myotonic Dystrophy Initially Presenting as Tachycardiomyopathy Successful Catheter Ablation of Atrial Flutter

    PubMed Central

    Asbach, S.; Gutleben, K. J.; Dahlem, P.; Brachmann, J.; Nölker, G.

    2010-01-01

    Myotonic dystrophy is a genetic muscular disease that is frequently associated with cardiac arrhythmias. Bradyarrhythmias, such as sinus bradycardia and atrioventricular block, are more common than tachyarrhythmias. Rarely, previously undiagnosed patients with myotonic dystrophy initially present with a tachyarrhythmia. We describe the case of a 14-year-old boy, who was admitted to the hospital with clinical signs and symptoms of decompensated heart failure and severely reduced left ventricular function. Electrocardiography showed common-type atrial flutter with 2 : 1 conduction resulting in a heart rate of 160 bpm. Initiation of medical therapy for heart failure as well as electrical cardioversion led to a marked clinical improvement. Catheter ablation of atrial flutter was performed to prevent future cardiac decompensations and to prevent development of tachymyopathy. Left ventricular function normalized during followup. Genetic analysis confirmed the clinical suspicion of myotonic dystrophy as known in other family members in this case. PMID:20871860

  17. Feasibility and safety of catheter ablation of electrical storm in ischemic dilated cardiomyopathy.

    PubMed

    Dello Russo, Antonio; Casella, Michela; Pelargonio, Gemma; Santangeli, Pasquale; Bartoletti, Stefano; Bencardino, Gianluigi; Al-Mohani, Ghaliah; Innocenti, Ester; Di Biase, Luigi; Avella, Andrea; Pappalardo, Augusto; Carbucicchio, Corrado; Bellocci, Fulvio; Fiorentini, Cesare; Natale, Andrea; Tondo, Claudio

    2016-06-01

    Electrical storm is an emergency in 'implantation of a cardioverter defibrillator' carriers with ischemic dilated cardiomyopathy (DCM) and negatively impacts long-term prognosis. We evaluated the feasibility, safety, and effectiveness of radiofrequency catheter ablation (RFCA) in controlling electrical storm and its impact on survival and ventricular tachycardia/fibrillation recurrence. We enrolled 27 consecutive patients (25 men, age 73.1 ± 6.5 years) with ischemic DCM and an indication to RFCA for drug-refractory electrical storm. The immediate outcome was defined as failure or success, depending on whether the patient's clinical ventricular tachycardia could still be induced after RFCA; electrical storm resolution was defined as no sustained ventricular tachycardia/ventricular fibrillation in the next 7 days. Of the 27 patients, 1 died before RFCA; in the remaining 26 patients, a total of 33 RFCAs were performed. In all 26 patients, RFCA was successful, although in 6/26 patients (23.1%), repeated procedures were needed, including epicardial ablation in 3/26 (11.5%). In 23/26 patients (88.5%), electrical storm resolution was achieved. At a follow-up of 16.7 ± 8.1 months, 5/26 patients (19.2%) had died (3 nonsudden cardiac deaths, 2 noncardiac deaths) and 10/26 patients (38.5%) had ventricular tachycardia recurrence; none had electrical storm recurrence. A worse long-term outcome was associated with lower glomerular filtration rate, wider baseline QRS, and presence of atrial fibrillation before electrical storm onset. In patients with ischemic DCM, RFCA is well tolerated, feasible and effective in the acute management of drug-refractory electrical storm. It is associated with a high rate of absence of sustained ventricular tachycardia episodes over the subsequent 7 days. After successful ablation, long-term outcome was mainly predicted by baseline clinical variables.

  18. Method and apparatus for the guided ablative therapy of fast ventricular arrhythmia

    NASA Technical Reports Server (NTRS)

    Cohen, Richard J. (Inventor); Barley, Maya (Inventor)

    2010-01-01

    Method and apparatus for guiding ablative therapy of abnormal biological electrical excitation. The excitation from the previous excitatory wave is significant at the beginning of the next excitation. In particular, it is designed for treatment of fast cardiac arrhythmias. Electrical signals are acquired from recording electrodes, and an inverse dipole method is used to identify the site of origin of an arrhythmia. The location of the tip of an ablation catheter is similarly localized from signals acquired from the recording electrodes while electrical pacing energy is delivered to the tip of the catheter close to or in contact with the cardiac tissue. The catheter tip is then guided to the site of origin of the arrhythmia, and ablative radio frequency energy is delivered to its tip to ablate the site.

  19. Direct His bundle pacing post AVN ablation.

    PubMed

    Lakshmanadoss, Umashankar; Aggarwal, Ashim; Huang, David T; Daubert, James P; Shah, Abrar

    2009-08-01

    Atrioventricular nodal (AVN) ablation with concomitant pacemaker implantation is one of the strategies that reduce symptoms in patients with atrial fibrillation (AF). However, the long-term adverse effects of right ventricular (RV) apical pacing have led to the search for alternating sites of pacing. Biventricular pacing produces a significant improvement in functional capacity over RV pacing in patients undergoing AVN ablation. Another alternative site for pacing is direct His bundle to reduce the adverse outcome of RV pacing. Here, we present a case of direct His bundle pacing using steerable lead delivery system in a patient with symptomatic paroxysmal AF with concurrent AVN ablation.

  20. The burden of proof: The current state of atrial fibrillation prevention and treatment trials.

    PubMed

    Zakeri, Rosita; Van Wagoner, David R; Calkins, Hugh; Wong, Tom; Ross, Heather M; Heist, E Kevin; Meyer, Timothy E; Kowey, Peter R; Mentz, Robert J; Cleland, John G; Pitt, Bertram; Zannad, Faiez; Linde, Cecilia

    2017-05-01

    Atrial fibrillation (AF) is an age-related arrhythmia of enormous socioeconomic significance. In recent years, our understanding of the basic mechanisms that initiate and perpetuate AF has evolved rapidly, catheter ablation of AF has progressed from concept to reality, and recent studies suggest lifestyle modification may help prevent AF recurrence. Emerging developments in genetics, imaging, and informatics also present new opportunities for personalized care. However, considerable challenges remain. These include a paucity of studies examining AF prevention, modest efficacy of existing antiarrhythmic therapies, diverse ablation technologies and practice, and limited evidence to guide management of high-risk patients with multiple comorbidities. Studies examining the long-term effects of AF catheter ablation on morbidity and mortality outcomes are not yet completed. In many ways, further progress in the field is heavily contingent on the feasibility, capacity, and efficiency of clinical trials to incorporate the rapidly evolving knowledge base and to provide substantive evidence for novel AF therapeutic strategies. This review outlines the current state of AF prevention and treatment trials, including the foreseeable challenges, as discussed by a unique forum of clinical trialists, scientists, and regulatory representatives in a session endorsed by the Heart Rhythm Society at the 12th Global CardioVascular Clinical Trialists Forum in Washington, DC, December 3-5, 2015. Copyright © 2017 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  1. Detection of electrophysiology catheters in noisy fluoroscopy images.

    PubMed

    Franken, Erik; Rongen, Peter; van Almsick, Markus; ter Haar Romeny, Bart

    2006-01-01

    Cardiac catheter ablation is a minimally invasive medical procedure to treat patients with heart rhythm disorders. It is useful to know the positions of the catheters and electrodes during the intervention, e.g. for the automatization of cardiac mapping. Our goal is therefore to develop a robust image analysis method that can detect the catheters in X-ray fluoroscopy images. Our method uses steerable tensor voting in combination with a catheter-specific multi-step extraction algorithm. The evaluation on clinical fluoroscopy images shows that especially the extraction of the catheter tip is successful and that the use of tensor voting accounts for a large increase in performance.

  2. Impact of Atrial Fibrillation Ablation on Left Ventricular Filling Pressure and Left Atrial Remodeling

    PubMed Central

    dos Santos, Simone Nascimento; Henz, Benhur Davi; Zanatta, André Rodrigues; Barreto, José Roberto; Loureiro, Kelly Bianca; Novakoski, Clarissa; dos Santos, Marcus Vinícius Nascimento; Giuseppin, Fabio F.; Oliveira, Edna Maria; Leite, Luiz Roberto

    2014-01-01

    Background Left ventricular (LV) diastolic dysfunction is associated with new-onset atrial fibrillation (AF), and the estimation of elevated LV filling pressures by E/e' ratio is related to worse outcomes in patients with AF. However, it is unknown if restoring sinus rhythm reverses this process. Objective To evaluate the impact of AF ablation on estimated LV filling pressure. Methods A total of 141 patients underwent radiofrequency (RF) ablation to treat drug-refractory AF. Transthoracic echocardiography was performed 30 days before and 12 months after ablation. LV functional parameters, left atrial volume index (LAVind), and transmitral pulsed and mitral annulus tissue Doppler (e' and E/e') were assessed. Paroxysmal AF was present in 18 patients, persistent AF was present in 102 patients, and long-standing persistent AF in 21 patients. Follow-up included electrocardiographic examination and 24-h Holter monitoring at 3, 6, and 12 months after ablation. Results One hundred seventeen patients (82.9%) were free of AF during the follow-up (average, 18 ± 5 months). LAVind reduced in the successful group (30.2 mL/m2 ± 10.6 mL/m2 to 22.6 mL/m2 ± 1.1 mL/m2, p < 0.001) compared to the non-successful group (37.7 mL/m2 ± 14.3 mL/m2 to 37.5 mL/m2 ± 14.5 mL/m2, p = ns). Improvement of LV filling pressure assessed by a reduction in the E/e' ratio was observed only after successful ablation (11.5 ± 4.5 vs. 7.1 ± 3.7, p < 0.001) but not in patients with recurrent AF (12.7 ± 4.4 vs. 12 ± 3.3, p = ns). The success rate was lower in the long-standing persistent AF patient group (57% vs. 87%, p = 0.001). Conclusion Successful AF ablation is associated with LA reverse remodeling and an improvement in LV filling pressure. PMID:25590928

  3. Slow pathway radiofrequency ablation in patients with AVNRT: junctional rhythm is less frequent during magnetic navigation ablation than with the conventional technique.

    PubMed

    Ricard, Philippe; Latcu, Decebal Gabriel; Yaïci, Khelil; Zarqane, Naima; Saoudi, Nadir

    2010-01-01

    The occurrence of accelerated junctional rhythm (JR) during radiofrequency ablation of the slow pathway in patients with atrioventricular nodal reentrant tachycardia (AVNRT) is frequent. The aim of the present study was to compare the occurrence of JR during magnetic remote catheter ablation to the conventional manual ablation. Twenty six patients (males: seven; age: 51 + or - 15 years) underwent slow pathway ablation with magnetic navigation (MN) system (Niobe, Stereotaxis Inc., St. Louis, MO, USA) and were compared to a control group of 11 patients (males: three; age: 53 + or - 16 years) treated with conventional manual ablation. A 4-mm nonirrigated tip catheter was used in both groups with a maximum of 30 W and 60 degrees C. Acute success was obtained in all patients. In the MN group, three patients out of 24 had no junctional beat (JB) at all and seven patients had 10 or less JB. In contrast, in the conventional group no patient had less than 10 JB. The mean number of JB in the MN group was 66 + or - 94.9 (0-410) and 200 + or - 243.1 (43-914) in the control group (P = 0.019). In the MN group one patient had a first-degree atrioventricular block. No other complication occurred. Magnetic remote catheter ablation of AVNRT is effective and is associated with less JB than the manual conventional technique. Therefore, JB may not be considered as a mandatory indicator for successful AVNRT ablation with MN system.

  4. The New 2016 European Society of Cardiology/European Association for Cardio-Thoracic Surgery Guidelines: Enough Guidance? Enough Evidence?

    PubMed

    Castellá, Manuel

    2018-04-01

    For the first time, the European Society of Cardiology and the European Association for Cardio-Thoracic Surgery have joined forces to develop consensus guidelines for the management of atrial fibrillation (AF). One of the main issues is the integrated care of patients with AF, with emphasis on multidisciplinary teams of general physicians, cardiologists, stroke specialists and surgeons, together with the patient's involvement for better management of AF. These guidelines also help in the detection of risk factors and concomitant cardiovascular diseases, stroke prevention therapies, including anticoagulation and antiplatelet therapies after acute coronary episodes, major haemorrhages or strokes. In the field of ablation, surgery plays an important role as concomitant with other surgical procedures, and it should be considered in symptomatic patients with the highest level of evidence. Asymptomatic patients with mitral insufficiency should also be considered for combined mitral and AF surgery if they have new-onset AF. In patients with stand-alone AF, recommendations for minimally invasive ablation have an increased level of recommendation and should be considered as the same level as catheter ablation in patients with persistent or long-standing persistent AF or with paroxysmal AF who fail catheter ablation. Surgical occlusion or exclusion of the left atrial appendage may be considered for stroke prevention in patients with AF about to have surgery. Nevertheless, not enough is known to avoid long-term anticoagulation in patients at risk of stroke even if the left atrial appendage has been excluded. These Guidelines provide a full spectrum of recommendations on the management of patients with AF including prevention, treatment and complications based on the latest published evidence.

  5. Effectiveness of atrial fibrillation rotor ablation is dependent on conduction velocity: An in-silico 3-dimensional modeling study

    PubMed Central

    Lim, Byounghyun; Hwang, Minki; Song, Jun-Seop; Ryu, Ah-Jin; Joung, Boyoung; Shim, Eun Bo; Ryu, Hyungon

    2017-01-01

    Background We previously reported that stable rotors are observed in in-silico human atrial fibrillation (AF) models, and are well represented by a dominant frequency (DF). In the current study, we hypothesized that the outcome of DF ablation is affected by conduction velocity (CV) conditions and examined this hypothesis using in-silico 3D-AF modeling. Methods We integrated 3D CT images of left atrium obtained from 10 patients with persistent AF (80% male, 61.8±13.5 years old) into in-silico AF model. We compared AF maintenance durations (max 300s), spatiotemporal stabilities of DF, phase singularity (PS) number, life-span of PS, and AF termination or defragmentation rates after virtual DF ablation with 5 different CV conditions (0.2, 0.3, 0.4, 0.5, and 0.6m/s). Results 1. AF maintenance duration (p<0.001), spatiotemporal mean variance of DF (p<0.001), and the number of PS (p = 0.023) showed CV dependent bimodal patterns (highest at CV0.4m/s and lowest at CV0.6m/s) consistently. 2. After 10% highest DF ablation, AF defragmentation rates were the lowest at CV0.4m/s (37.8%), but highest at CV0.5 and 0.6m/s (all 100%, p<0.001). 3. In the episodes with AF termination or defragmentation followed by 10% highest DF ablation, baseline AF maintenance duration was shorter (p<0.001), spatiotemporal mean variance of DF was lower (p = 0.014), and the number of PS was lower (p = 0.004) than those with failed AF defragmentation after DF ablation. Conclusion Virtual ablation of DF, which may indicate AF driver, was more likely to terminate or defragment AF with spatiotemporally stable DF, but not likely to do so in long-lasting and sustained AF conditions, depending on CV. PMID:29287119

  6. Direct cooling of the catheter tip increases safety for CMR-guided electrophysiological procedures

    PubMed Central

    2012-01-01

    Background One of the safety concerns when performing electrophysiological (EP) procedures under magnetic resonance (MR) guidance is the risk of passive tissue heating due to the EP catheter being exposed to the radiofrequency (RF) field of the RF transmitting body coil. Ablation procedures that use catheters with irrigated tips are well established therapeutic options for the treatment of cardiac arrhythmias and when used in a modified mode might offer an additional system for suppressing passive catheter heating. Methods A two-step approach was chosen. Firstly, tests on passive catheter heating were performed in a 1.5 T Avanto system (Siemens Healthcare Sector, Erlangen, Germany) using a ASTM Phantom in order to determine a possible maximum temperature rise. Secondly, a phantom was designed for simulation of the interface between blood and the vascular wall. The MR-RF induced temperature rise was simulated by catheter tip heating via a standard ablation generator. Power levels from 1 to 6 W were selected. Ablation duration was 120 s with no tip irrigation during the first 60 s and irrigation at rates from 2 ml/min to 35 ml/min for the remaining 60 s (Biotronik Qiona Pump, Berlin, Germany). The temperature was measured with fluoroscopic sensors (Luxtron, Santa Barbara, CA, USA) at a distance of 0 mm, 2 mm, 4 mm, and 6 mm from the catheter tip. Results A maximum temperature rise of 22.4°C at the catheter tip was documented in the MR scanner. This temperature rise is equivalent to the heating effect of an ablator's power output of 6 W at a contact force of the weight of 90 g (0.883 N). The catheter tip irrigation was able to limit the temperature rise to less than 2°C for the majority of examined power levels, and for all examined power levels the residual temperature rise was less than 8°C. Conclusion Up to a maximum of 22.4°C, the temperature rise at the tissue surface can be entirely suppressed by using the catheter's own irrigation system. The irrigated tip

  7. Outcome of stand-alone thoracoscopic epicardial left atrial posterior box isolation with bipolar radiofrequency energy for longstanding persistent atrial fibrillation.

    PubMed

    Compier, M G; Braun, J; Tjon, A; Zeppenfeld, K; Klautz, R J M; Schalij, M J; Trines, S A

    2016-02-01

    Catheter ablation of longstanding (> 1 year) persistent atrial fibrillation (AF) is associated with poor outcome. This might be due to remodelling and fibrosis formation, mainly located in the posterior left atrial (LA) wall. Therefore, we adopted a thoracoscopic epicardial box isolation of the posterior left atrium using bipolar RF energy with intraoperative testing of conduction block. Bilateral thoracoscopic box isolation was performed with a bipolar RF clamp. Entrance block was defined as absence of a conducted electrogram within the box, while exit block was confirmed by pacing at 10.0 V/2 ms. Ablation outcome was evaluated after 3, 6, 12 and 24 months with 12-lead ECGs and 24-hour Holter recordings. Twenty-five consecutive patients were included (58 ± 7 years, persistent AF duration 1.8 ± 0.9 years). Entrance block was achieved in all patients and exit block confirmed if sinus rhythm was achieved. After 17 ± 7 months, 76 % of the patients (n = 19) were free of AF recurrence. One patient died within 1 month and was considered an ablation failure. Four patients with AF recurrences regained sinus rhythm with additional catheter ablation or antiarrhythmic drugs. Treatment of longstanding persistent AF with thoracoscopic epicardial LA posterior box isolation using bipolar RF energy with intraoperative testing of conduction block is feasible and highly effective.

  8. Localization of gaps during redo ablations of paroxysmal atrial fibrillation: Preferential patterns depending on the choice of cryoballoon ablation or radiofrequency ablation for the initial procedure.

    PubMed

    Galand, Vincent; Pavin, Dominique; Behar, Nathalie; Auffret, Vincent; Fénéon, Damien; Behaghel, Albin; Daubert, Jean-Claude; Mabo, Philippe; Martins, Raphaël P

    2016-11-01

    Pulmonary vein (PV) isolation, using cryoballoon or radiofrequency ablation, is the cornerstone therapy for symptomatic paroxysmal atrial fibrillation (AF) refractory to antiarrhythmic drugs. One-third of the patients have recurrences, mainly due to PV reconnections. To describe the different locations of reconnection sites in patients who had previously undergone radiofrequency or cryoballoon ablation, and to compare the characteristics of the redo procedures in both instances. Demographic data and characteristics of the initial ablation (cryoballoon or radiofrequency) were collected. Number and localization of reconduction gaps, and redo characteristics were reviewed. Seventy-four patients scheduled for a redo ablation of paroxysmal AF were included; 38 had been treated by radiofrequency ablation and 36 by cryoballoon ablation during the first procedure. For the initial ablation, procedural and fluoroscopy times were significantly shorter for cryoballoon ablation (147.8±52.6min vs. 226.6±64.3min [P<0.001] and 37.0±17.7min vs. 50.8±22.7min [P=0.005], respectively). Overall, an identical number of gaps was found during redo procedures of cryoballoon and radiofrequency ablations. However, a significantly higher number of gaps were located in the right superior PV for patients first ablated with radiofrequency (0.9±1.0 vs. 0.5±0.9; P=0.009). Gap localization displayed different patterns. Although not significant, redo procedures of cryoballoon ablation were slightly shorter and needed shorter durations of radiofrequency to achieve PV isolation. During redo procedures, gap localization pattern is different for patients first ablated with cryoballoon or radiofrequency ablation, and right superior PV reconnections occur more frequently after radiofrequency ablation. Redo ablation of a previous cryoballoon ablation appears to be easier. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  9. CO laser angioplasty system: efficacy of manipulatable laser angioscope catheter

    NASA Astrophysics Data System (ADS)

    Arai, Tsunenori; Kikuchi, Makoto; Mizuno, Kyoichi; Sakurada, Masami; Miyamoto, Akira; Arakawa, Koh; Kurita, Akira; Nakamura, Haruo; Takeuchi, Kiyoshi; Utsumi, Atsushi; Akai, Yoshiro

    1992-08-01

    A percutaneous transluminal coronary angioplasty system using a unique combination of CO laser (5 micrometers ) and As-S infrared glass fiber under the guidance of a manipulatable laser angioscope catheter is described. The ablation and guidance functions of this system are evaluated. The angioplasty treatment procedure under angioscope guidance was studied by in vitro model experiment and in vivo animal experiment. The whole angioplasty system is newly developed. That is, a transportable compact medical CO laser device which can emit up to 10 W, a 5 F manipulatable laser angioscope catheter, a thin CO laser cable of which the diameter is 0.6 mm, an angioscope imaging system for laser ablation guidance, and a system controller were developed. Anesthetized adult mongrel dogs (n equals 5) with an artificial complete occlusion in the femoral artery and an artificial human vessel model including occluded or stenotic coronary artery were used. The manipulatability of the catheter was drastically improved (both rotation and bending), therefore, precise control of ablation to expand stenosis was obtained. A 90% artificial stenosis made of human yellow plaque in 4.0 mm diameter in the vessel was expanded to 70% stenosis by repetitive CO laser ablations of which total energy was 220 J. All procedures were performed and controlled under angioscope visualization.

  10. Early Efficacy Analysis of Biatrial Ablation versus Left and Simplified Right Atrial Ablation for Atrial Fibrillation Treatment in Patients with Rheumatic Heart Disease.

    PubMed

    Liu, Hong; Chen, Lin; Xiao, Yingbin; Ma, Ruiyan; Hao, Jia; Chen, Baicheng; Qin, Chuan; Cheng, Wei

    2015-08-01

    Atrial fibrillation (AF) is the most common sustained arrhythmia. About 60% of patients with rheumatic heart disease have persistent AF. A total of 197 patients underwent valve replacement concomitant bipolar radiofrequency ablation (BRFA). Patients were divided into the biatrial ablation group and the simplified right atrial ablation group. In biatrial ablation group, the patients underwent a complete left and right atrial ablation. In simplified right atrial ablation group, the patients underwent a complete left atrial ablation and a simplified right atrial ablation. The conversion of sinus rhythm (SR) was high in both groups during the follow-up period. In the simplified right atrial ablation group, SR conversion rate was 88.29% at discharge. At six months and 12 months after surgery, 87.39% of patients and 86.49% of patients were in SR free of antiarrhythmic drugs, respectively. While in the biatrial ablation group, SA conversion rate was 89.53% at discharge. Percentage of patients in SR free of antiarrhythmic drugs was 88.37% and 88.37% at six months and 12 months after surgery, respectively. Echocardiography showed left atrial diameter decreased significantly after the surgery in the two groups. The ejection fraction and fractional shortening were improved significantly, without significant differences between the two groups. The results suggest that the concomitant left atrial and simplified right atrial BRFA for AF in patients undergoing valve replacement can achieve similar early efficiency as biatrial ablation. Copyright © 2015 Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). Published by Elsevier B.V. All rights reserved.

  11. Late outcomes after the Cox maze IV procedure for atrial fibrillation.

    PubMed

    Henn, Matthew C; Lancaster, Timothy S; Miller, Jacob R; Sinn, Laurie A; Schuessler, Richard B; Moon, Marc R; Melby, Spencer J; Maniar, Hersh S; Damiano, Ralph J

    2015-11-01

    The Cox maze IV procedure (CMPIV) has been established as the gold standard for surgical ablation; however, late outcomes using current consensus definitions of treatment failure have not been well described. To compare to reported outcomes of catheter-based ablation, we report our institutional outcomes of patients who underwent a left-sided or biatrial CMPIV at 5 years of follow-up. Between January 2002 and September 2014, data were collected prospectively on 576 patients with AF who underwent a CMPIV (n = 532) or left-sided CMPIV (n = 44). Perioperative variables and long-term freedom from AF, with and without AADs, were compared in multiple subgroups. Follow-up at any time point was 89%. At 5 years, overall freedom from AF was 93 of 119 (78%), and freedom from AF off AADs was 77 of 177 (66%). No differences were found in freedom from AF, with or without AADs, at 1, 2, 3, 4, and 5 years for patients with paroxysmal AF (n = 204) versus with persistent/longstanding persistent AF (n = 305), or for those who underwent standalone versus a concomitant CMP. Duration of preoperative AF and hospital length of stay were the best predictors of failure at 5 years. The outcomes of the CMPIV remain good at late follow-up. The type of preoperative AF or the addition of a concomitant procedure did not affect late success. The results of the CMPIV remain superior to those reported for catheter ablation and other forms of surgical AF ablation, especially for patients with persistent or longstanding AF. Copyright © 2015 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.

  12. Panoramic Electrophysiological Mapping but not Electrogram Morphology Identifies Stable Sources for Human Atrial Fibrillation

    PubMed Central

    Narayan, Sanjiv M.; Shivkumar, Kalyanam; Krummen, David E.; Miller, John M.; Rappel, Wouter-Jan

    2013-01-01

    Background The foundation for successful arrhythmia ablation is the mapping of electric propagation to identify underlying mechanisms. In atrial fibrillation (AF), however, mapping is difficult so that ablation has often targeted electrogram features, with mixed results. We hypothesized that wide field-of-view (panoramic) mapping of both atria would identify causal mechanisms for AF and allow interpretation of local electrogram features, including complex fractionated atrial electrograms (CFAE). Methods and Results Contact mapping was performed using biatrial multipolar catheters in 36 AF subjects (29 persistent). Stable AF rotors (spiral waves) or focal sources were seen in 35 of 36 cases and targeted for ablation (focal impulse and rotor modulation) before pulmonary vein isolation. In 31 of 36 subjects (86.1%), AF acutely terminated (n=20; 16 to sinus rhythm) or organized (n=11; 19±8% slowing) with 2.5 minutes focal impulse and rotor modulation (interquartile range, 1.0–3.1) at one source, defined as the primary source. Subjects exhibited 2.1±1.0 concurrent AF sources of which the primary, by phase mapping, precessed in limited areas (persistent 2.5±1.7 versus paroxysmal 1.7±0.5 cm2; P=0.30). Notably, source regions showed mixed electrogram amplitudes and CFAE grades that did not differ from surrounding atrium (P=NS). AF sources were not consistently surrounded by CFAE (P=0.67). Conclusions Stable rotors and focal sources for human AF were revealed by contact panoramic mapping (focal impulse and rotor modulation mapping), but not by electrogram footprints. AF sources precessed within areas of ≈2 cm2, with diverse voltage characteristics poorly correlated with CFAE. Most CFAE sites lie remote from AF sources and are not suitable targets for catheter ablation of AF. PMID:23392583

  13. Cardiac memory in patients with Wolff-Parkinson-White syndrome: noninvasive imaging of activation and repolarization before and after catheter ablation.

    PubMed

    Ghosh, Subham; Rhee, Edward K; Avari, Jennifer N; Woodard, Pamela K; Rudy, Yoram

    2008-08-26

    Cardiac memory refers to a change in ventricular repolarization induced by and persisting for minutes to months after cessation of a period of altered ventricular activation (eg, resulting from pacing or preexcitation in patients with Wolff-Parkinson-White syndrome). ECG imaging (ECGI) is a novel imaging modality for noninvasive electroanatomic mapping of epicardial activation and repolarization. Fourteen pediatric patients with Wolff-Parkinson-White syndrome and no other congenital disease, were imaged with ECGI a day before and 45 minutes, 1 week, and 1 month after successful catheter ablation. ECGI determined that preexcitation sites were consistent with sites of successful ablation in all cases to within a 1-hour arc of each atrioventricular annulus. In the preexcited rhythm, activation-recovery interval (ARI) was the longest (349+/-6 ms) in the area of preexcitation leading to high average base-to-apex ARI dispersion of 95+/-9 ms (normal is approximately 40 ms). The ARI dispersion remained the same 45 minutes after ablation, although the activation sequence was restored to normal. ARI dispersion was still high (79+/-9 ms) 1 week later and returned to normal (45+/-6 ms) 1 month after ablation. The study demonstrates that ECGI can noninvasively localize ventricular insertion sites of accessory pathways to guide ablation and evaluate its outcome in pediatric patients with Wolff-Parkinson-White syndrome. Wolff-Parkinson-White is associated with high ARI dispersion in the preexcited rhythm that persists after ablation and gradually returns to normal over a period of 1 month, demonstrating the presence of cardiac memory. The 1-month time course is consistent with transcriptional reprogramming and remodeling of ion channels.

  14. Prediction and prognosis of ventricular tachycardia recurrence after catheter ablation with remote magnetic navigation for electrical storm in patients with ischemic cardiomyopathy.

    PubMed

    Jin, Qi; Jacobsen, Peter Karl; Pehrson, Steen; Chen, Xu

    2017-11-01

    Ventricular tachycardia (VT) recurrence after catheter ablation for electrical storm is commonly seen in patients with ischemic cardiomyopathy (ICM). We hypothesized that VT recurrence can be predicted and be related to the all-cause death after VT storm ablation guided by remote magnetic navigation (RMN) in patients with ICM. A total of 54 ICM patients (87% male; mean age, 65 ± 7.1 years) presenting with VT storm undergoing acute ablation using RMN were enrolled. Acute complete ablation success was defined as noninducibility of any sustained monomorphic VT at the end of the procedure. Early VT recurrence was defined as the occurrence of sustained VT within 1 month after the first ablation. After a mean follow-up of 17.1 months, 27 patients (50%) had freedom from VT recurrence. Sustained VT recurred in 12 patients (22%) within 1 month following the first ablation. In univariate analysis, VT recurrence was associated with incomplete procedural success (hazard ratio [HR]: 6.25, 95% confidence interval [CI]: 1.20-32.47, P = 0.029), lack of amiodarone usage before ablation (HR: 4.71, 95% CI: 1.12-19.7, P = 0.034), and a longer procedural time (HR: 1.023, 95% CI: 1.00-1.05, P = 0.05). The mortality of patients with early VT recurrence was higher than that of patients without recurrence (P < 0.01). Inducibility of any VT at the end of procedure for VT storm guided by RMN is the strongest predictor of VT recurrence. ICM patients who have early recurrences after VT storm ablation are at high risk of all-cause death. © 2017 Wiley Periodicals, Inc.

  15. Epidemiological profile of Wolff-Parkinson-White syndrome in a general population younger than 50 years of age in an era of radiofrequency catheter ablation.

    PubMed

    Lu, Chun-Wei; Wu, Mei-Hwan; Chen, Hui-Chi; Kao, Feng-Yu; Huang, San-Kuei

    2014-07-01

    The prevalence of Wolff-Parkinson-White (WPW) syndrome varies between 0.68 and 1.7/1000. The epidemiological profile may be modified after the introduction of transcatheter interventions. The aim of this study is to investigate the epidemiological trends of the WPW syndrome in a general population during a period with available and reimbursed transcatheter ablation. Data of WPW patients <50 years old were retrieved from our national database (2000-2010). We identified 6086 (61% male) patients, accounting for an overall prevalence of 0.36/1000 with a peak of 0.61/1000 in ages 20-24 years. The risk of death and sudden death was 0.071% and 0.02% per patient-year, respectively. The 42 deaths occurred at a median age of 29 years. Associated congenial heart disease was noted in 158 (2.6%) patients, including 42 with Ebstein's anomaly that increased the mortality risk (P=0.001, OR=8.5). In those without congenital heart disease, myocardial dysfunction occurred in 115 (1.9%) patients and increased the risk of death (P<0.001, OR=10.6) and sudden death. Radiofrequency catheter ablation was performed in 2527 patients at a median age of 25.7 years (4.54% per patient-year, discharge mortality 0.16%); 11 (0.4%) before the age of 5, and 2231 (88%) after the age of 15. Whereas repeated ablation procedures accounted for 6.0% of the procedures, those in Ebstein's patients were 25%. Radiofrequency catheter ablation is already a common treatment for WPW patients, particularly during young adulthood, which accounts for a lower prevalence. Myocardial dysfunction and associated congenital heart disease remain as risks of mortality. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  16. Long-term outcomes following high intensity focused ultrasound ablation for atrial fibrillation.

    PubMed

    Davies, Edward J; Bazerbashi, Samer; Asopa, Sanjay; Haywood, Guy; Dalrymple-Hay, Malcolm

    2014-01-01

    The aim of this study is to assess the safety and efficacy of the Epicor high intensity focused ultrasound (St. Jude, Inc.®, Minneapolis, MN, USA) system using seven-day ambulatory electrocardiogram (ECG) monitoring over a two-year follow-up period. One hundred and ten patients undergoing ablation were included from a single center between January 2006 and December 2009. Rhythm was assessed using seven-day ambulatory ECG or permanent pacemaker interrogation. Seventeen patients were lost to follow-up, seven through death. Results were reported according to atrial fibrillation (AF) class preoperatively: paroxysmal, persistent, and long-standing persistent (LSP). Forty-nine percent of patients remained in sinus rhythm at greater than two years. The percentage of patients in sinus rhythm according to preoperative AF class were 81% (paroxysmal AF), 56% (persistent AF), and 18% (long-standing AF). The class of AF prior to surgery, left atrium size, and body mass index determined the long-term outcome. There were no procedure-related complications. We conclude that high intensity focused ultrasound ablation for atrial fibrillation using the Epicor system is safe and effective for surgical patients with paroxysmal AF. The persistent and LSP AF results suggest that alternative ablation strategies should be considered for these patients. © 2013 Wiley Periodicals, Inc.

  17. REAL TIME MRI GUIDED RADIOFREQUENCY ATRIAL ABLATION AND VISUALIZATION OF LESION FORMATION AT 3-TESLA

    PubMed Central

    Vergara, Gaston R.; Vijayakumar, Sathya; Kholmovski, Eugene G.; Blauer, Joshua J.E.; Guttman, Mike A.; Gloschat, Christopher; Payne, Gene; Vij, Kamal; Akoum, Nazem W.; Daccarett, Marcos; McGann, Christopher J.; MacLeod, Rob S.; Marrouche, Nassir F.

    2011-01-01

    Background MRI allows visualization of location and extent of RF ablation lesion, myocardial scar formation, and real-time (RT) assessment of lesion formation. In this study, we report a novel 3-Tesla RT-MRI based porcine RF ablation model and visualization of lesion formation in the atrium during RF energy delivery. Objective To develop of a 3-Tesla RT-MRI based catheter ablation and lesion visualization system. Methods RF energy was delivered to six pigs under RT-MRI guidance. A novel MRI compatible mapping and ablation catheter was used. Under RT-MRI this catheter was safely guided and positioned within either the left or right atrium. Unipolar and bi-polar electrograms were recorded. The catheter tip-tissue interface was visualized with a T1-weighted gradient echo sequence. RF energy was then delivered in a power-controlled fashion. Myocardial changes and lesion formation were visualized with a T2-weighted (T2w) HASTE sequence during ablation. Results Real-time visualization of lesion formation was achieved in 30% of the ablations performed. In the other cases, either the lesion was formed outside the imaged region (25%) or lesion was not created (45%) presumably due to poor tissue-catheter tip contact. The presence of lesions was confirmed by late gadolinium enhancement (LGE) MRI and macroscopic tissue examination. Conclusion MRI compatible catheters can be navigated and RF energy safely delivered under 3-Tesla RT-MRI guidance. It is also feasible to record electrograms during RT imaging. Real-time visualization of lesion as it forms during delivery of RF energy is possible and was demonstrated using T2w HASTE imaging. PMID:21034854

  18. Management of ventricular tachycardia in the ablation era: results of the European Heart Rhythm Association Survey.

    PubMed

    Tilz, Roland Richard; Lenarczyk, Radoslaw; Scherr, Daniel; Haugaa, Kristina Herman; Iliodromitis, Konstantinos; Pürerfellner, Helmut; Kiliszek, Marek; Dagres, Nikolaos

    2018-01-01

    Patients with sustained ventricular tachycardia (VT) are at risk of sudden death. Treatment options for VT include antiarrhythmic drug therapy, insertion of an implantable cardioverter-defibrillator, and catheter ablation. Evidence on indications for VT ablation, timing, ablation strategies, and periprocedural management is sparse. The aim of this European Heart Rhythm Association (EHRA) survey was to evaluate clinical practice regarding management of VT among the European countries. An electronic questionnaire was sent to members of the EHRA Electrophysiology Research Network. Responses were received from 88 centres in 12 countries. The results have shown that management of VTs is very heterogeneous across the participating centres. Indications, periprocedural management, and ablation strategies vary substantially. This EP Wire survey has revealed that catheter ablation is the first-line therapy for the treatment of recurrent monomorphic stable VT in patients without structural heart disease as well as in patients with ischaemic cardiomyopathy and impaired left ventricular ejection fraction in the majority of centres. Furthermore, in patients with ischaemic cardiomyopathy and the first episode of monomorphic VT, most centres (62.0%) performed catheter ablation. On the contrary, in patients with non-ischaemic cardiomyopathy, amiodarone (41.4%) and catheter ablation (37.1%) are used in a very similar proportion. Ablation strategies, endpoints, and post-ablation antithrombotic management vary substantially among European centres. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2017. For permissions, please email: journals.permissions@oup.com.

  19. Trends in U.S. Hospitalizations Rates and Rhythm Control Therapies Following Publication of the AFFIRM and RACE Trials

    PubMed Central

    Martin-Doyle, William; Essebag, Vidal; Zimetbaum, Peter; Reynolds, Matthew R.

    2010-01-01

    Introduction The impact of trials comparing rate vs. rhythm control for AF on subsequent use of rhythm control therapies and hospitalizations at a national level has not been described. Methods and Results We queried the Healthcare Cost & Utilization Project on the frequency of hospital admissions and performance of specific rhythm control procedures from 1998–2006. We analyzed trends in hospitalization for AF as principal diagnosis before and after the publication of key rate vs. rhythm trials in 2002. We also reviewed the use of electrical cardioversion and catheter ablation as principal procedures during hospital admissions for any cause and for AF as principal diagnosis. We additionally appraised the overall outpatient utilization of antiarrhythmic drugs during this same time frame using IMS Health’s National Prescription Audit.™ Admissions for AF as a principal diagnosis increased at 5%/year from 1998–2002. Following publication of the AFFIRM and RACE trials in 2002, admissions declined by 2%/year from 2002–2004, before rising again from 2004–06. In-hospital electrical cardioversion followed a similar pattern. National prescription volumes for antiarrhythmic drugs grew at <1%/yr from 2002–06, with a marked decline in the use of Class I-A agents, while catheter ablations during admissions for AF as the principal diagnosis increased at 30%/year. Conclusion The use of rhythm control therapies in the U.S. declined significantly in the first few years after publication of AFFIRM and RACE. This trend reversed by 2005, at which time rapid growth in the use of catheter ablation for AF was observed. PMID:21087329

  20. Impact of obesity on atrial fibrillation ablation: Patient characteristics, long-term outcomes, and complications.

    PubMed

    Winkle, Roger A; Mead, R Hardwin; Engel, Gregory; Kong, Melissa H; Fleming, William; Salcedo, Jonathan; Patrawala, Rob A

    2017-06-01

    There is an association between obesity and atrial fibrillation (AF). The impact of obesity on AF ablation procedures is unclear. The purpose of this study was to evaluate the influence of body mass index (BMI) on patient characteristics, long-term ablation outcomes, and procedural complications. We evaluated 2715 patients undergoing 3742 AF ablation procedures. BMI was ≥30 kg/m 2 in 1058 (39%) and ≥40 kg/m 2 in 129 (4.8%). Patients were grouped by BMI ranges (<25, 25-<30, 30-<35, 35-<40, and ≥40 kg/m 2 ). As BMI increased from <25 to ≥40 kg/m 2 , age decreased from 65.3 ± 11.2 to 61.2 ± 9.2 years (P < .001), left atrial size increased from 3.91 ± 0.68 to 4.72 ± 0.62 cm (P < .005), and CHADS 2 scores increased from 1.24 ± 1.10 to 1.62 ± 1.09 (P < .001). As BMI increased, paroxysmal AF decreased from 48.0% to 16.3% (P < .0001) and there was an increase in dilated cardiomyopathy (from 7.6% to 12.4%; P < .0001), hypertension (from 41.0% to 72.9%; P < .0001), diabetes (from 4.3% to 23.3%; P < .0001), and sleep apnea (from 7.0% to 46.9%; P < .0001). For the entire cohort, for BMI ≥35 kg/m 2 the 5-year ablation freedom from AF decreased from 67%-72% to 57% (P = .036). For paroxysmal AF, when BMI was ≥40 kg/m 2 ablation success decreased from 79%-82% to 60% (P = .064), and for persistent AF, when BMI was ≥35 kg/m 2 ablation success decreased from 64%-70% to 52%-57% (P = .021). For long-standing AF, there was no impact of BMI on outcomes (P = .624). In multivariate analysis, BMI ≥35 kg/m 2 predicted worse outcomes (P = .036). Higher BMI did not impact major complication rates (P = .336). However, when BMI was ≥40 kg/m 2 , minor (from 2.1% to 4.4%; P = .035) and total (from 3.5% to 6.7%; P = .023) complications increased. In patients undergoing AF ablation, increasing BMI is associated with more patient comorbidities and more persistent and long-standing AF. BMI ≥35 kg/m 2 adversely impacts ablation outcomes, and BMI ≥40 kg/m 2 increases minor

  1. Use of bipolar radiofrequency catheter ablation in treatment of cardiac arrhythmias.

    PubMed

    Soucek, Filip; Starek, Zdenek

    2018-05-23

    Background Arrhythmia management is a complex process involving both pharmacological and non-pharmacological approaches. Radiofrequency ablation is the pillar of non-pharmacological arrhythmia treatment. Unipolar ablation is considered to be the gold standard in the treatment of the majority of arrhythmias; however, its efficacy is limited to specific cases. In particular, the creation of deep or transmural lesions to eliminate intramurally originating arrhythmias remains inadequate. Bipolar ablation is proposed as an alternative to overcome unipolar ablation boundaries. Results Despite promising results gained from in vitro and animal studies showing that bipolar ablation is superior in creating transmural lesions, the use of bipolar ablation in daily clinical practice is limited. Several studies have been published showing that bipolar ablation is effective in the treatment of clinical arrhythmias after failed unipolar ablation, however there is inconsistency regarding safety of bipolar ablation within the available research papers. According to research evidence the most common indications for bipolar ablation use are ventricular originating rhythmic disorders in patients with structural heart disease resistant to standard radiofrequency ablation. Conclusions To allow wider clinical application the efficiency and safety of bipolar ablation need to be verified in future studies. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  2. Expression of TGFbeta1 in pulmonary vein stenosis after radiofrequency ablation in chronic atrial fibrillation of dogs.

    PubMed

    Li, Shufeng; Li, Hongli; Mingyan, E; Yu, Bo

    2009-02-01

    The development of pulmonary vein stenosis has recently been described after radiofrequency ablation (RF) to treat atrial fibrillation (AF). The purpose of this study was to examine expression of TGFbeta1 in pulmonary vein stenosis after radiofrequency ablation in chronic atrial fibrillation of dogs. About 28 mongrel dogs were randomly assigned to the sham-operated group (n = 7), the AF group (n = 7), AF + RF group (n = 7), and RF group (n = 7). In AF or AF + RF groups, dogs underwent chronic pulmonary vein (PV) pacing to induce sustained AF. RF application was applied around the PVs until electrical activity was eliminated. Histological assessment of pulmonary veins was performed using hematoxylin and eosin staining; TGFbeta1 gene expression in pulmonary veins was examined by RT-PCR analysis; expression of TGFbeta1 protein in pulmonary veins was assessed by Western blot analysis. Rapid pacing from the left superior pulmonary vein (LSPV) induced sustained AF in AF group and AF + RF group. Pulmonary vein ablation terminated the chronic atrial fibrillation in dogs. Histological examination revealed necrotic tissues in various stages of collagen replacement, intimal thickening, and cartilaginous metaplasia with chondroblasts and chondroclasts. Compared with sham-operated and AF group, TGFbeta1 gene and protein expressions was increased in AF + RF or RF groups. It was concluded that TGFbeta1 might be associated with pulmonary vein stenosis after radiofrequency ablation in chronic atrial fibrillation of dogs.

  3. [Catheter ablation for paroxysmal atrial fibrillation: new generation cryoballoon or contact force sensing radiofrequency ablation?].

    PubMed

    Nagy, Zsófia; Kis, Zsuzsanna; Som, Zoltán; Földesi, Csaba; Kardos, Attila

    2016-05-29

    Contact force sensing radiofrequency ablation and the new generation cryoballoon ablation are prevalent techniques for the treatment of paroxysmal atrial fibrillation. The authors aimed to compare the procedural and 1-year outcome of patients after radiofrequency and cryoballoon ablation. 96 patients with paroxysmal atrial fibrillation (radiofrequency ablation: 58, cryoballoon: 38 patients; 65 men and 31 women aged 28-70 years) were enrolled. At postprocedural 1, 3, 6 and 12 months ECG, Holter monitoring and telephone interviews were performed. Procedure and fluorosocopy time were: radiofrequency ablation, 118.5 ± 15 min and 15.8 ± 6 min; cryoballoon, 73.5 ± 16 min (p<0.05) and 13.8 ± 4.,1 min (p = 0.09), respectively. One year later freedom from atrial fibrillation was achieved in 76.5% of patients who underwent radiofrequency ablation and in 81% of patients treated with cryoballoon. Temporary phrenic nerve palsy occurred in two patients and pericardial tamponade developed in one patient. In this single center study freedom from paroxysmal atrial fibrillation was similar in the two groups with significant shorter procedure time in the cryoballoon group.

  4. Long-term follow-up of patients with paroxysmal atrial fibrillation and severe left atrial scarring: comparison between pulmonary vein antrum isolation only or pulmonary vein isolation combined with either scar homogenization or trigger ablation.

    PubMed

    Mohanty, Sanghamitra; Mohanty, Prasant; Di Biase, Luigi; Trivedi, Chintan; Morris, Eli Hamilton; Gianni, Carola; Santangeli, Pasquale; Bai, Rong; Sanchez, Javier E; Hranitzky, Patrick; Gallinghouse, G Joseph; Al-Ahmad, Amin; Horton, Rodney P; Hongo, Richard; Beheiry, Salwa; Elayi, Claude S; Lakkireddy, Dhanunjaya; Madhu Reddy, Yaruva; Viles Gonzalez, Juan F; Burkhardt, J David; Natale, Andrea

    2017-11-01

    Left atrial (LA) scarring, a consequence of cardiac fibrosis is a powerful predictor of procedure-outcome in atrial fibrillation (AF) patients undergoing catheter ablation. We sought to compare the long-term outcome in patients with paroxysmal AF (PAF) and severe LA scarring identified by 3D mapping, undergoing pulmonary vein isolation (PVAI) only or PVAI and the entire scar areas (scar homogenization) or PVAI+ ablation of the non-PV triggers. Totally, 177 consecutive patients with PAF and severe LA scarring were included. Patients underwent PVAI only (n = 45, Group 1), PVAI+ scar homogenization (n = 66, Group 2) or PVAI+ ablation of non-PV triggers (n = 66, Group 3) based on operator's choice. Baseline characteristics were similar across the groups. After first procedure, all patients were followed-up for a minimum of 2 years. The success rate at the end of the follow-up was 18% (8 pts), 21% (14 pts), and 61% (40 pts) in Groups 1, 2, and 3, respectively. Cumulative probability of AF-free survival was significantly higher in Group 3 (overall log-rank P <0.01, pairwise comparison 1 vs. 3 and 2 vs. 3 P < 0.01). During repeat procedures, non-PV triggers were ablated in all. After average 1.5 procedures, the success rates were 28 (62%), 41 (62%), and 56 (85%) in Groups 1, 2, and 3, respectively (log-rank P< 0.001). In patients with PAF and severe LA scarring, PVAI+ ablation of non-PV triggers is associated with significantly better long-term outcome than PVAI alone or PVAI+ scar homogenization. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2016. For Permissions, please email: journals.permissions@oup.com.

  5. Polish and European management strategies in patients with atrial fibrillation. Data from the EURObservational Research Programme-Atrial Fibrillation General Registry Pilot Phase (EORP-AF Pilot).

    PubMed

    Lenarczyk, Radosław; Mitręga, Katarzyna; Mazurek, Michał; Janion, Marianna; Opolski, Grzegorz; Drożdż, Jarosław; Streb, Witold; Fuglewicz, Artur; Sokal, Adam; Laroche, Cécile; Lip, Gregory Y H; Kalarus, Zbigniew

    2016-01-01

    Despite continued efforts of the European Society of Cardiology (ESC) to unify management of patients with atrial fibrillation (AF) across Europe, interregional differences in guideline adherence are likely. The aim of the study was to compare treatment strategies depending on baseline characteristics of AF patients between Poland and other members of the European Union (EU). We analyzed the baseline data and treatment strategies in participants of the ESC registry: the EURObservational Research Programme-Atrial Fibrillation General Registry Pilot Phase. A total of 3119 consecutive patients with AF diagnosed within the last year were included in 67 centers from 9 countries, including 419 patients enrolled in 15 Polish centers. A rhythm control strategy was more frequent in Poland than in other EU countries (20.8% vs 11.9%; P <0.0001). Catheter ablation for AF was also used more frequently in Polish cardiology wards (13.9% vs 8.3%; P = 0.0017), while amiodarone at discharge was used less frequently (12.0% vs 22.7%; P <0.0001). In-hospital use of vitamin K antagonists (VKAs) and non-VKA anticoagulants was less frequent in Polish patients with a CHA2DS2-VASc score of 2 or higher than in patients from other EU countries (61.1% vs 79.0%; P <0.0001), but overall anticoagulation rates at discharge were similar to those in other countries (83.3% vs 82.6%). A rhythm control-oriented strategy in patients with AF with the use of ablation in cardiology wards is more frequent in Poland than in other EU countries. Similar to other EU countries, compliance with the ESC guidelines regarding anticoagulation in AF patients is suboptimal in Poland. Undertreatment was observed in a significant proportion of patients at high risk of stroke, while a large group of low-risk patients are overtreated. Differences between the types of recruiting centers in Poland and other EU countries might have influenced the results.

  6. Increase in pulmonary arterial pressure after atrial fibrillation ablation: incidence and associated findings.

    PubMed

    Witt, Chance M; Fenstad, Eric R; Cha, Yong-Mei; Kane, Garvan C; Kushwaha, Sudhir S; Hodge, David O; Asirvatham, Samuel J; Oh, Jae K; Packer, Douglas L; Powell, Brian D

    2014-06-01

    The stiff left atrial (LA) syndrome is defined as pulmonary hypertension (PH) secondary to reduced LA compliance and has recently been shown to be one cause of PH after atrial fibrillation (AF) ablation. We aimed to determine the incidence of an increase in pulmonary arterial (PA) pressure post-ablation and examine the clinical and echocardiographic associations. Patients who underwent AF ablation between 1999 and 2011 were included if they had both an echocardiogram pre-ablation and 3 months post-ablation. Patients were then separated into two groups with the increased PA pressure group defined as patients with >10 mmHg increase in right ventricular systolic pressure (RVSP) post-ablation and a post-ablation RVSP >35 mmHg. Of the 499 patients meeting the study criteria, 41 (8.2%) had an increase in RVSP >10 mmHg and RVSP >35 mmHg post-ablation. On echocardiogram, the two groups had similar E/A and E/e' ratios pre-ablation. However, post-ablation, the increased PA pressure group had higher E/A (2.12 vs. 1.49, p < 0.01) and E/e' (14.7 vs. 11.2, p < 0.01) ratios. LA expansion index values were lower in the increased PA pressure group pre-ablation (51 vs. 92%, p < 0.01), but not significantly different post-ablation (82 vs. 88%, p = 0.44). Around 8% of patients develop an increase in estimated PA pressure after AF ablation. Echocardiographic parameters suggest that patients who develop increased PA pressure are developing (or unmasking) left ventricular diastolic dysfunction.

  7. The impact of B-type natriuretic peptide levels on the suppression of accompanying atrial fibrillation in Wolff-Parkinson-White syndrome patients after accessory pathway ablation.

    PubMed

    Kawabata, Mihoko; Goya, Masahiko; Takagi, Takamitsu; Yamashita, Shu; Iwai, Shinsuke; Suzuki, Masahito; Takamiya, Tomomasa; Nakamura, Tomofumi; Hayashi, Tatsuya; Yagishita, Atsuhiko; Sasaki, Takeshi; Takahashi, Yoshihide; Ono, Yuhichi; Hachiya, Hitoshi; Yamauchi, Yasuteru; Otomo, Kenichiro; Nitta, Junichi; Okishige, Kaoru; Nishizaki, Mitsuhiro; Iesaka, Yoshito; Isobe, Mitsuaki; Hirao, Kenzo

    2016-12-01

    Atrial fibrillation (AF) often coexists with Wolff-Parkinson-White (WPW) syndrome. We compared the efficacy of Kent bundle ablation alone and additional AF ablation on accompanying AF, and examined which patients would still have a risk of AF after successful Kent bundle ablation. This retrospective multicenter study included 96 patients (56±15 years, 72 male) with WPW syndrome and AF undergoing Kent bundle ablation. Some patients underwent simultaneous pulmonary vein isolation (PVI) for AF. The incidence of post-procedural AF was examined. Sixty-four patients underwent only Kent bundle ablation (Kent-only group) and 32 also underwent PVI (+PVI group). There was no significant difference in the basic patient characteristics between the groups. Additional PVI did not improve the freedom from residual AF compared to Kent bundle ablation alone (p=0.53). In the Kent-only group, AF episodes remained in 25.0% during the follow-up (709 days). A univariate analysis showed that age ≥60 years, left atrial dimension ≥38mm, B-type natriuretic peptide (BNP) ≥40pg/ml, and concomitant hypertension were predictive factors for residual AF. However, in the multivariate analysis, only BNP ≥40pg/ml remained as an independent predictive factor (HR=17.1 and CI: 2.3-128.2; p=0.006). Among patients with WPW syndrome and AF, Kent bundle ablation alone may have a sufficient clinical impact of preventing recurrence of AF in select patients. Screening the BNP level would help decide the strategy to manage those patients. Copyright © 2016 Japanese College of Cardiology. Published by Elsevier Ltd. All rights reserved.

  8. Observation of the efficacy of radiofrequency catheter ablation on patients with different forms of atrial fibrillation.

    PubMed

    Zhao, R-C; Han, W; Han, J; Yu, J; Guo, J; Fu, J-L; Li, Z; Zhao, R-Z

    2016-10-01

    To study the efficacy and safety of radiofrequency catheter ablation (RFCA) in patients with different forms of atrial fibrillation. By retrospective analysis, we summarize 720 cases, where patients diagnosed with atrial fibrillation in our hospital were treated with RFCA from February 2010 to October 2014. Among the cases, 425 were diagnosed with paroxysmal atrial fibrillation and 295 with non-paroxysmal atrial fibrillation (including persistent atrial fibrillation and permanent atrial fibrillation). All patients were followed up until June 2015 to compare and analyze the differences in operation success rates, complications and recurrence rates. 395 cases (92.9%) of paroxysmal atrial fibrillation and 253 cases (85.8%) with non-paroxysmal atrial fibrillation were subject to surgery and followed up. The age of onset, disease course, underlying diseases, left atrial diameter and combined anti-arrhythmics of patients with paroxysmal atrial fibrillation were lower than those of patients with non-paroxysmal atrial fibrillation, and the differences were statistically significant (p < 0.05). The success rate of the first ablation was higher than that of non-paroxysmal atrial fibrillation. Procedure time, procedure method, complications and recurrence rate of patients with paroxysmal atrial fibrillation were lower than those of non-paroxysmal atrial fibrillation group, and the differences were statistically significant (p < 0.05). When we compared apoplexy and heart failure caused by atrial fibrillation in the two groups, the difference was not statistically significant (Apoplexy: p = 0.186; Heart failure: p = 0.170). The individual ablation success rate was higher for paroxysmal atrial fibrillation, and long-term follow-up showed that the occurrence of apoplexy and heart failure was not different from the non-paroxysmal atrial fibrillation group.

  9. Development of a force-reflecting robotic platform for cardiac catheter navigation.

    PubMed

    Park, Jun Woo; Choi, Jaesoon; Pak, Hui-Nam; Song, Seung Joon; Lee, Jung Chan; Park, Yongdoo; Shin, Seung Min; Sun, Kyung

    2010-11-01

    Electrophysiological catheters are used for both diagnostics and clinical intervention. To facilitate more accurate and precise catheter navigation, robotic cardiac catheter navigation systems have been developed and commercialized. The authors have developed a novel force-reflecting robotic catheter navigation system. The system is a network-based master-slave configuration having a 3-degree of freedom robotic manipulator for operation with a conventional cardiac ablation catheter. The master manipulator implements a haptic user interface device with force feedback using a force or torque signal either measured with a sensor or estimated from the motor current signal in the slave manipulator. The slave manipulator is a robotic motion control platform on which the cardiac ablation catheter is mounted. The catheter motions-forward and backward movements, rolling, and catheter tip bending-are controlled by electromechanical actuators located in the slave manipulator. The control software runs on a real-time operating system-based workstation and implements the master/slave motion synchronization control of the robot system. The master/slave motion synchronization response was assessed with step, sinusoidal, and arbitrarily varying motion commands, and showed satisfactory performance with insignificant steady-state motion error. The current system successfully implemented the motion control function and will undergo safety and performance evaluation by means of animal experiments. Further studies on the force feedback control algorithm and on an active motion catheter with an embedded actuation mechanism are underway. © 2010, Copyright the Authors. Artificial Organs © 2010, International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  10. Origin and ablation of the adenosine triphosphate induced atrial fibrillation after circumferential pulmonary vein isolation: effects on procedural success rate.

    PubMed

    Zhang, Jinlin; Tang, Cheng; Zhang, Yonghua; Su, X I

    2014-04-01

    Adenosine triphosphate (ATP) has been used to provoke dormant pulmonary vein (PV) conduction after circumferential PV isolation (CPVI). However, there have been no systematic studies examining the incidence and the mechanism of ATP-induced atrial fibrillation (AF) following CPVI in paroxysmal AF. In this study, we explore the mechanism of ATP-induced AF and assess the feasibility of eliminating this response by additional radiofrequency (RF) ablation. A total of 300 consecutive patients with paroxysmal AF underwent CPVI. After all PVs were isolated, intravenous ATP (40 mg) was administered during an intravenous isoproterenol (ISP) infusion (5 μg/min). AF was reproducibly induced by ATP in 39 patients. Non-PV foci were confirmed and located in 29 of these patients at the onset of AF, including 27 foci in the superior vena cava (SVC), 1 focus in the crista terminalis, and 1 focus near the antrum of the PV. In all these cases, ATP-induced AF was eliminated after the non-PV foci were successfully ablated. For the other 10 patients, the foci triggering AF could not be confirmed or located due to the transient effect of ATP, thus no further ablation was performed. After a mean follow-up period of 18.7 ± 6.4 (8-24) months, the success rate in the ATP-induced AF group was not significantly different compared with the conventional treatment group who did not exhibit ATP-induced AF (76.9% vs 67.3%; P = 0.25). But in the subgroup of which the ATP-induced AF could be eliminated by additional RF ablation, the success rate was significantly higher than the non-ATP inducible group (86.2% vs 67.3%; P = 0.04). A large proportion of the ATP-induced AF post CPVI were initiated by rapid firing in the SVC. Eliminating this response by additional ablation may have an influence on clinical results of paroxysmal AF ablation. © 2014 Wiley Periodicals, Inc.

  11. Is Cryoballoon Ablation Preferable to Radiofrequency Ablation for Treatment of Atrial Fibrillation by Pulmonary Vein Isolation? A Meta-Analysis

    PubMed Central

    Xu, Junxia; Huang, Yingqun; Cai, Hongbin; Qi, Yue; Jia, Nan; Shen, Weifeng; Lin, Jinxiu; Peng, Feng; Niu, Wenquan

    2014-01-01

    Objective Currently radiofrequency and cryoballoon ablations are the two standard ablation systems used for catheter ablation of atrial fibrillation; however, there is no universal consensus on which ablation is the optimal choice. We therefore sought to undertake a meta-analysis with special emphases on comparing the efficacy and safety between cryoballoon and radiofrequency ablations by synthesizing published clinical trials. Methods and Results Articles were identified by searching the MEDLINE and EMBASE databases before September 2013, by reviewing the bibliographies of eligible reports, and by consulting with experts in this field. Data were extracted independently and in duplicate. There were respectively 469 and 635 patients referred for cryoballoon and radiofrequency ablations from 14 qualified clinical trials. Overall analyses indicated that cryoballoon ablation significantly reduced fluoroscopic time and total procedure time by a weighted mean of 14.13 (95% confidence interval [95% CI]: 2.82 to 25.45; P = 0.014) minutes and 29.65 (95% CI: 8.54 to 50.77; P = 0.006) minutes compared with radiofrequency ablation, respectively, whereas ablation time in cryoballoon ablation was nonsignificantly elongated by a weighted mean of 11.66 (95% CI: −10.71 to 34.04; P = 0.307) minutes. Patients referred for cryoballoon ablation had a high yet nonsignificant success rate of catheter ablation compared with cryoballoon ablation (odds ratio; 95% CI; P: 1.34; 0.53 to 3.36; 0.538), and cryoballoon ablation was also found to be associated with the relatively low risk of having recurrent atrial fibrillation (0.75; 0.3 to 1.88; 0.538) and major complications (0.46; 0.11 to 1.83; 0.269). There was strong evidence of heterogeneity and low probability of publication bias. Conclusion Our findings demonstrate greater improvement in fluoroscopic time and total procedure duration for atrial fibrillation patients referred for cryoballoon ablation than those for

  12. Quantitative Analysis of Localized Sources Identified by Focal Impulse and Rotor Modulation Mapping in Atrial Fibrillation

    PubMed Central

    Benharash, Peyman; Buch, Eric; Frank, Paul; Share, Michael; Tung, Roderick; Shivkumar, Kalyanam; Mandapati, Ravi

    2015-01-01

    Background New approaches to ablation of atrial fibrillation (AF) include focal impulse and rotor modulation (FIRM) mapping, and initial results reported with this technique have been favorable. We sought to independently evaluate the approach by analyzing quantitative characteristics of atrial electrograms used to identify rotors and describe acute procedural outcomes of FIRM-guided ablation. Methods and Results All FIRM-guided ablation procedures (n=24; 50% paroxysmal) at University of California, Los Angeles Medical Center were included for analysis. During AF, unipolar atrial electrograms collected from a 64-pole basket catheter were used to construct phase maps and identify putative AF sources. These sites were targeted for ablation, in conjunction with pulmonary vein isolation in most patients (n=19; 79%). All patients had rotors identified (mean, 2.3±0.9 per patient; 72% in left atrium). Prespecified acute procedural end point was achieved in 12 of 24 (50%) patients: AF termination (n=1), organization (n=3), or >10% slowing of AF cycle length (n=8). Basket electrodes were within 1 cm of 54% of left atrial surface area, and a mean of 31 electrodes per patient showed interpretable atrial electrograms. Offline analysis revealed no differences between rotor and distant sites in dominant frequency or Shannon entropy. Electroanatomic mapping showed no rotational activation at FIRM-identified rotor sites in 23 of 24 patients (96%). Conclusions FIRM-identified rotor sites did not exhibit quantitative atrial electrogram characteristics expected from rotors and did not differ quantitatively from surrounding tissue. Catheter ablation at these sites, in conjunction with pulmonary vein isolation, resulted in AF termination or organization in a minority of patients (4/24; 17%). Further validation of this approach is necessary. PMID:25873718

  13. Efficacy and safety of the second-generation cryoballoons versus radiofrequency ablation for the treatment of paroxysmal atrial fibrillation: a systematic review and meta-analysis.

    PubMed

    Jiang, Jingbo; Li, Jinyi; Zhong, Guoqiang; Jiang, Junjun

    2017-01-01

    Currently, radiofrequency (RF) and cryoballoon are the most commonly used ablation technologies for atrial fibrillation (AF). We performed a meta-analysis to assess the efficacy and safety of the second-generation cryoballoons (CB-2) compared with RF for paroxysmal atrial fibrillation (PAF) ablation. The PubMed, Cochrane Library, and Embase databases were searched and qualified studies were identified. The primary clinical outcome was the recurrence rate of atrial tachyarrhythmia (AT), and the secondary clinical outcomes were procedure time, fluoroscopy time, and the complications that followed. Nine observational studies (2336 patients) with a mean follow-up period ranging from 8.8 to 16.8 months were included. The CB-2 group was associated with a significantly lower recurrence rate of ATs (20.8 versus 29.8 %, p = 0.01). In subgroup analysis, compared with non-contact force sensing (NCF) catheter, using CB-2 showed significantly reduced incidence of ATs (22.0 versus 38.5 %, p < 0.00001). However, the difference became negligible in contrast with contact force sensing (CF) catheter. Moreover, the CB-2 group had a tendency to decrease procedure time (weighted mean difference -39.72 min, p = 0.0003), whereas fluoroscopy time was similar between the two groups. The total complication rate showed no statistical difference (8.8 versus 4.4 %, p = 0.08). Almost all the cases of phrenic nerve palsy occurred in the CB-2 group, whereas pericardial tamponade was seldom manifested in the CB-2 group. CB-2 tended to be more effective in comparison to NCF catheter and at least non-inferior to CF catheter, with shorter procedure time and similar safety endpoint.

  14. Brain Emboli After Left Ventricular Endocardial Ablation.

    PubMed

    Whitman, Isaac R; Gladstone, Rachel A; Badhwar, Nitish; Hsia, Henry H; Lee, Byron K; Josephson, S Andrew; Meisel, Karl M; Dillon, William P; Hess, Christopher P; Gerstenfeld, Edward P; Marcus, Gregory M

    2017-02-28

    Catheter ablation for ventricular tachycardia and premature ventricular complexes (PVCs) is common. Catheter ablation of atrial fibrillation is associated with a risk of cerebral emboli attributed to cardioversions and numerous ablation lesions in the low-flow left atrium, but cerebral embolic risk in ventricular ablation has not been evaluated. We enrolled 18 consecutive patients meeting study criteria scheduled for ventricular tachycardia or PVC ablation over a 9-month period. Patients undergoing left ventricular (LV) ablation were compared with a control group of those undergoing right ventricular ablation only. Patients were excluded if they had implantable cardioverter defibrillators or permanent pacemakers. Radiofrequency energy was used for ablation in all cases and heparin was administered with goal-activated clotting times of 300 to 400 seconds for all LV procedures. Pre- and postprocedural brain MRI was performed on each patient within a week of the ablation procedure. Embolic infarcts were defined as new foci of reduced diffusion and high signal intensity on fluid-attenuated inversion recovery brain MRI within a vascular distribution. The mean age was 58 years, half of the patients were men, half had a history of hypertension, and the majority had no known vascular disease or heart failure. LV ablation was performed in 12 patients (ventricular tachycardia, n=2; PVC, n=10) and right ventricular ablation was performed exclusively in 6 patients (ventricular tachycardia, n=1; PVC, n=5). Seven patients (58%) undergoing LV ablation experienced a total of 16 cerebral emboli, in comparison with zero patients undergoing right ventricular ablation ( P =0.04). Seven of 11 patients (63%) undergoing a retrograde approach to the LV developed at least 1 new brain lesion. More than half of patients undergoing routine LV ablation procedures (predominately PVC ablations) experienced new brain emboli after the procedure. Future research is critical to understanding the

  15. Integrated HIFU Drive System on a Chip for CMUT-Based Catheter Ablation System.

    PubMed

    Farhanieh, Omid; Sahafi, Ali; Bardhan Roy, Rupak; Ergun, Arif Sanli; Bozkurt, Ayhan

    2017-06-01

    Conventional High Intensity Focused Ultrasound (HIFU) is a therapeutic modality which is extracorporeally administered. In applications where a relatively small HIFU lesion is required, an intravascular HIFU probe can be deployed to the ablation site. In this paper, we demonstrate the design and implementation a fully integrated HIFU drive system on a chip to be placed on a 6 Fr catheter probe. An 8-element capacitive micromachined ultrasound transducer (CMUT) ring array of 2 mm diameter has been used as the ultrasound source. The driver chip is fabricated in 0.35 μm AMS high-voltage CMOS technology and comprises eight continuous-wave (CW) high-voltage CMUT drivers (10.9 ns and 9.4 ns rise and fall times at 20 V pp output into a 15 pF), an eight-channel digital beamformer (8-12 MHz output frequency with 11.25 ° phase accuracy) and a phase locked loop with an integrated VCO as a tunable clock source (128-192 MHz). The chip occupies 1.85 × 1.8 mm 2 area including input and output (I/O) pads. When the transducer array is immersed in sunflower oil and driven by the IC with eight 20 V pp CW pulses at 10 MHz, real-time thermal images of the HIFU beam indicate that the focal temperature rises by 16.8  ° C in 11 seconds. Each HV driver consumes around 67 mW of power when driving the CMUT array at 10 MHz, which adds up to 560 mW for the whole chip. FEM based analysis reveals that the outer surface temperature of the catheter is expected to remain below the 42  ° C tissue damage limit during therapy.

  16. Is HATCH score a reliable predictor of atrial fibrillation after cavotricuspid isthmus ablation for typical atrial flutter?

    PubMed

    García-Seara, Javier; Gude Sampedro, Francisco; Martínez Sande, Jose L; Fernández López, Xesus Alberte; Rodríguez Mañero, Moisés; González Melchor, Laila; Alvarez Alvarez, Belén; Iglesias Alvarez, Diego; González Juanatey, José Ramón

    2016-09-01

    We determined the effectiveness of the HATCH score in patients with typical atrial flutter (AFl) undergoing cavotricuspid isthmus (CTI) ablation to predict long-term atrial fibrillation (AF). We conducted an observational retrospective single-center cohort study including all patients admitted to our hospital for a CTI ablation between 1998 and 2010. The patients were divided into four categories: 1) new-onset AF (no prior AF and AF during follow-up (FU)); 2) old AF (prior AF and no AF during FU); 3) prior and post AF (AF prior and post CTI ablation); and 4) no AF. Four hundred and eight patients were included. In patients without prior AF, the hazard ratio (HR) for new-onset AF during FU was 0.98 (CI 95%: 0.65-1.50; p = 0.95) and 1.00 (CI 95%: 0.57-1.77; p = 0.98) for HATCH ≥ 2 and HATCH ≥ 3, respectively. In patients with prior AF, the HR for AF was 1.41 (CI 95%: 0.87-2.28; p = 0.17) and 1.79 (CI 95%: 0.96-3.35; p = 0.06), for HATCH ≥ 2 and HATCH ≥ 3, respectively. Left atrial enlargement was positively correlated with the occurrence of AF during FU, especially in the subgroup without prior AF, which had a HR of 2.44 (CI 95%: 1.35-4.40; p = 0.003), a HR of 2.88 (CI 95%: 1.36-6.10; p = 0.006) and a HR of 3.68 (CI 95%: 1.71-7.94; p = 0.001), for slight, moderate and severely dilated left atrial dimension, respectively, compared with a normal value. HATCH score did not predict AF in patients with typical AFl who underwent CTI ablation. Basal left atrium dimension could help predict new-onset AF.

  17. Wolff-Parkinson-White syndrome in the era of catheter ablation: insights from a registry study of 2169 patients.

    PubMed

    Pappone, Carlo; Vicedomini, Gabriele; Manguso, Francesco; Saviano, Massimo; Baldi, Mario; Pappone, Alessia; Ciaccio, Cristiano; Giannelli, Luigi; Ionescu, Bogdan; Petretta, Andrea; Vitale, Raffaele; Cuko, Amarild; Calovic, Zarko; Fundaliotis, Angelica; Moscatiello, Mario; Tavazzi, Luigi; Santinelli, Vincenzo

    2014-09-02

    The management of Wolff-Parkinson-White is based on the distinction between asymptomatic and symptomatic presentations, but evidence is limited in the asymptomatic population. The Wolff-Parkinson-White registry was an 8-year prospective study of either symptomatic or asymptomatic Wolff-Parkinson-White patients referred to our Arrhythmology Department for evaluation or ablation. Inclusion criteria were a baseline electrophysiological testing with or without radiofrequency catheter ablation (RFA). Primary end points were the percentage of patients who experienced ventricular fibrillation (VF) or potentially malignant arrhythmias and risk factors. Among 2169 enrolled patients, 1001 (550 asymptomatic) did not undergo RFA (no-RFA group) and 1168 (206 asymptomatic) underwent ablation (RFA group). There were no differences in clinical and electrophysiological characteristics between the 2 groups except for symptoms. In the no-RFA group, VF occurred in 1.5% of patients, virtually exclusively (13 of 15) in children (median age, 11 years), and was associated with a short accessory pathway antegrade refractory period (P<0.001) and atrioventricular reentrant tachycardia initiating atrial fibrillation (P<0.001) but not symptoms. In the RFA group, ablation was successful in 98.5%, and after RFA, no patients developed malignant arrhythmias or VF over the 8-year follow-up. Untreated patients were more likely to experience malignant arrhythmias and VF (log-rank P<0.001). Time-dependent receiver-operating characteristic curves for predicting VF identified an optimal anterograde effective refractory period of the accessory pathway cutoff of 240 milliseconds. The prognosis of the Wolff-Parkinson-White syndrome essentially depends on intrinsic electrophysiological properties of AP rather than on symptoms. RFA performed during the same procedure after electrophysiological testing is of benefit in improving the long-term outcomes. © 2014 American Heart Association, Inc.

  18. Surgical RF ablation of atrial fibrillation in patients undergoing mitral valve repair for Barlow disease.

    PubMed

    Rostagno, Carlo; Droandi, G; Gelsomino, S; Carone, E; Gensini, G F; Stefàno, P L

    2013-01-01

    At present, limited experience exists on the treatment of atrial fibrillation (AF) in patients undergoing mitral valve repair (MVR) for Barlow disease. The aim of this investigation was to prospectively evaluate the radiofrequency ablation of AF in patients undergoing MVR for severe regurgitation due to Barlow disease. From January 1, 2007 to December 31, 2010, out of 85 consecutive patients with Barlow disease, 27 with AF underwent RF ablation associated with MVR. They were examined every 4 months in the first year after surgery and thereafter twice yearly. At follow-up, AF was observed in 4/25 (16.0%). NYHA (New York Heart Association) functional class improved significantly, with no patients in class III or IV (before surgery, 81.5% had been). Otherwise, among 58 patients in sinus rhythm, 6 (11%) developed AF during follow-up. No clinical or echocardiographic predictive factor was found in this subgroup. Results from our investigation suggest that radiofrequency ablation of AF in patients with Barlow disease undergoing MVR for severe regurgitation is effective and should be considered in every patient with Barlow disease and AF undergoing valve surgical repair. Copyright © 2013 S. Karger AG, Basel.

  19. Pace-capture-guided ablation after contact-force-guided pulmonary vein isolation: results of the randomized controlled DRAGON trial.

    PubMed

    Masuda, Masaharu; Fujita, Masashi; Iida, Osamu; Okamoto, Shin; Ishihara, Takayuki; Nanto, Kiyonori; Kanda, Takashi; Sunaga, Akihiro; Tsujimura, Takuya; Matsuda, Yasuhiro; Ohashi, Takuya; Uematsu, Masaaki

    2017-11-17

    Before the discovery of contact-force guidance, eliminating pacing capture along the pulmonary vein (PV) isolation line had been reported to improve PV isolation durability and rhythm outcomes. DRAGON (UMIN-CTR, UMIN000015332) aimed to elucidate the efficacy of pace-capture-guided ablation following contact-force-guided PV isolation ablation in paroxysmal atrial fibrillation (AF) patients. A total of 156 paroxysmal AF patients with AF-trigger ectopies from any of the four PVs induced by isoproterenol were randomly assigned to undergo pace-capture-guided ablation along a contact-force-guided isolation line around AF-trigger PVs (PC group, n = 76) or contact-force-guided PV isolation ablation alone (control group, n = 80). Follow-up of at least 1 year commenced with serial 24 h Holter and symptom-triggered ambulatory monitoring. There was no significant difference in acute PV reconnection rates during a 20 min waiting period after the last ablation or adenosine infusion testing between the PC and the control groups (per patient, 21% vs. 27%, P = 0.27; per AF-trigger PV, 5.9% vs. 7.3%, P = 0.70; and per non-AF-trigger PV, 7.1% vs. 7.4%, P = 0.92). Atrial tachyarrhythmia-free survival rates off antiarrhythmic drugs after the initial session were comparable at 19.3 ± 6.2 months between the two groups (82% vs. 80%, P = 0.80). Among 22 patients who required a second ablation procedure, there was no difference between the PC and the control groups in the PV reconnection rates at both previously AF-trigger (29% vs. 43%, P = 0.70) and non-AF-trigger PVs (18% vs. 19%, P = 0.88). Pace-capture-guided ablation performed after contact-force-guided PV isolation demonstrated no improvement in PV isolation durability or rhythm outcome. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2017. For permissions, please email: journals.permissions@oup.com.

  20. Automated planning of ablation targets in atrial fibrillation treatment

    NASA Astrophysics Data System (ADS)

    Keustermans, Johannes; De Buck, Stijn; Heidbüchel, Hein; Suetens, Paul

    2011-03-01

    Catheter based radio-frequency ablation is used as an invasive treatment of atrial fibrillation. This procedure is often guided by the use of 3D anatomical models obtained from CT, MRI or rotational angiography. During the intervention the operator accurately guides the catheter to prespecified target ablation lines. The planning stage, however, can be time consuming and operator dependent which is suboptimal both from a cost and health perspective. Therefore, we present a novel statistical model-based algorithm for locating ablation targets from 3D rotational angiography images. Based on a training data set of 20 patients, consisting of 3D rotational angiography images with 30 manually indicated ablation points, a statistical local appearance and shape model is built. The local appearance model is based on local image descriptors to capture the intensity patterns around each ablation point. The local shape model is constructed by embedding the ablation points in an undirected graph and imposing that each ablation point only interacts with its neighbors. Identifying the ablation points on a new 3D rotational angiography image is performed by proposing a set of possible candidate locations for each ablation point, as such, converting the problem into a labeling problem. The algorithm is validated using a leave-one-out-approach on the training data set, by computing the distance between the ablation lines obtained by the algorithm and the manually identified ablation points. The distance error is equal to 3.8+/-2.9 mm. As ablation lesion size is around 5-7 mm, automated planning of ablation targets by the presented approach is sufficiently accurate.

  1. Atrial fibrillation patients with isolated pulmonary veins: Is sinus rhythm achievable?

    PubMed

    Szilágyi, Judit; Marcus, Gregory M; Badhwar, Nitish; Lee, Byron K; Lee, Randall J; Vedantham, Vasanth; Tseng, Zian H; Walters, Tomos; Scheinman, Melvin; Olgin, Jeffrey; Gerstenfeld, Edward P

    2017-07-01

    The cornerstone of atrial fibrillation (AF) ablation is isolation of the pulmonary veins (PVs). Patients with recurrent AF undergoing repeat ablation usually have PV reconnection (PVr). The ablation strategy and outcome of patients undergoing repeat ablation who have persistent isolation of all PVs (PVi) at the time of repeat ablation is unknown. We studied consecutive patients with recurrent AF undergoing repeat ablation and compared patients with PVi to those with PVr. One hundred fifty-two patients underwent repeat ablation, and of these, 25 patients (16.4%) had PVi. Patients with PVi underwent ablation targeting any isoproterenol induced AF triggers, atrial substrate, or inducible atrial tachycardias or flutters. Patients with PVi compared to PVr were more likely to have a history of persistent AF (64% vs. 26%; P < 0.0001), obesity (BMI 30.4 vs. 28.2; P = 0.05), and prior use of contact force sensing catheters (28% vs. 0.8%, P < 0.0001). After a mean follow-up of 19 ± 15 months, 56% of PVi patients remained in sinus rhythm compared to 76.3% of PVr patients (P = 0.036). In a multivariable model, PVi patients and those with cardiomyopathy had a higher risk of recurrent atrial tachyarrhythmias (HR = 3.6 95%, CI 1.6-8.3, P = 0.002 and HR = 6.2, 95% CI 2.3-16.3, P < 0.0001, respectively). In patients who have all PVs isolated at the time of the redo AF ablation, a strategy of targeting non-PV AF triggers and inducible flutters can still lead to AF freedom in more than half of patients. Patients with PVr, however, have a better long-term outcome. © 2017 Wiley Periodicals, Inc.

  2. Real-time magnetic resonance imaging-guided radiofrequency atrial ablation and visualization of lesion formation at 3 Tesla.

    PubMed

    Vergara, Gaston R; Vijayakumar, Sathya; Kholmovski, Eugene G; Blauer, Joshua J E; Guttman, Mike A; Gloschat, Christopher; Payne, Gene; Vij, Kamal; Akoum, Nazem W; Daccarett, Marcos; McGann, Christopher J; Macleod, Rob S; Marrouche, Nassir F

    2011-02-01

    Magnetic resonance imaging (MRI) allows visualization of location and extent of radiofrequency (RF) ablation lesion, myocardial scar formation, and real-time (RT) assessment of lesion formation. In this study, we report a novel 3-Tesla RT -RI based porcine RF ablation model and visualization of lesion formation in the atrium during RF energy delivery. The purpose of this study was to develop a 3-Tesla RT MRI-based catheter ablation and lesion visualization system. RF energy was delivered to six pigs under RT MRI guidance. A novel MRI-compatible mapping and ablation catheter was used. Under RT MRI, this catheter was safely guided and positioned within either the left or right atrium. Unipolar and bipolar electrograms were recorded. The catheter tip-tissue interface was visualized with a T1-weighted gradient echo sequence. RF energy was then delivered in a power-controlled fashion. Myocardial changes and lesion formation were visualized with a T2-weighted (T2W) half Fourier acquisition with single-shot turbo spin echo (HASTE) sequence during ablation. RT visualization of lesion formation was achieved in 30% of the ablations performed. In the other cases, either the lesion was formed outside the imaged region (25%) or the lesion was not created (45%) presumably due to poor tissue-catheter tip contact. The presence of lesions was confirmed by late gadolinium enhancement MRI and macroscopic tissue examination. MRI-compatible catheters can be navigated and RF energy safely delivered under 3-Tesla RT MRI guidance. Recording electrograms during RT imaging also is feasible. RT visualization of lesion as it forms during RF energy delivery is possible and was demonstrated using T2W HASTE imaging. Copyright © 2011 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  3. Validation of a novel mapping system and utility for mapping complex atrial tachycardias.

    PubMed

    Honarbakhsh, S; Hunter, R J; Dhillon, G; Ullah, W; Keating, E; Providencia, R; Chow, A; Earley, M J; Schilling, R J

    2018-03-01

    This study sought to validate a novel wavefront mapping system utilizing whole-chamber basket catheters (CARTOFINDER, Biosense Webster). The system was validated in terms of (1) mapping atrial-paced beats and (2) mapping complex wavefront patterns in atrial tachycardia (AT). Patients undergoing catheter ablation for AT and persistent AF were included. A 64-pole-basket catheter was used to acquire unipolar signals that were processed by CARTOFINDER mapping system to generate dynamic wavefront propagation maps. The left atrium was paced from four sites to demonstrate focal activation. ATs were mapped with the mechanism confirmed by conventional mapping, entrainment, and response to ablation. Twenty-two patients were included in the study (16 with AT and 6 with AF initially who terminated to AT during ablation). In total, 172 maps were created with the mapping system. It correctly identified atrial-pacing sites in all paced maps. It accurately mapped 9 focal/microreentrant and 18 macroreentrant ATs both in the left and right atrium. A third and fourth observer independently identified the sites of atrial pacing and the AT mechanism from the CARTOFINDER maps, while being blinded to the conventional activation maps. This novel mapping system was effectively validated by mapping focal activation patterns from atrial-paced beats. The system was also effective in mapping complex wavefront patterns in a range of ATs in patients with scarred atria. The system may therefore be of practical use in the mapping and ablation of AT and could have potential for mapping wavefront activations in AF. © 2018 Wiley Periodicals, Inc.

  4. Simultaneous assessment of contact pressure and local electrical coupling index using robotic navigation.

    PubMed

    Dello Russo, Antonio; Fassini, Gaetano; Casella, Michela; Bologna, Fabrizio; Al-Nono, Osama; Colombo, Daniele; Biagioli, Viviana; Santangeli, Pasquale; Di Biase, Luigi; Zucchetti, Martina; Majocchi, Benedetta; Marino, Vittoria; Gallinghouse, Joseph J; Natale, Andrea; Tondo, Claudio

    2014-06-01

    Contact with cardiac tissue is a determinant of lesion efficacy during atrial fibrillation (AF) ablation. The Sensei®X Robotic Catheter System (Hansen Medical, CA) has been validated for contact force sensing. The electrical coupling index (ECI) from the EnSite Contact™ system (St. Jude Medical, MN) has been validated as an indicator of tissue contact. We aimed at analyzing ECI behavior during radiofrequency (RF) pulses maintaining a stable contact through the robotic navigation contact system. In 15 patients (age, 59 ± 12) undergoing AF ablation, pulmonary vein (PV) isolation was guided by the Sensei®X System, employing the Contact™ catheter. During the procedure, we assessed ECI changes associated with adequate contact based on the IntelliSense® force-sensing technology (Hansen Medical, CA. Baseline contact (27 ± 8 g/cm(2)) ECI value was 99 ± 13, whereas ECI values in a noncontact site (0 g/cm(2)) and in a light contact site (1-10 g/cm(2)) were respectively 66 ± 12 and 77 ± 10 (p < 0.0001). Baseline contact ECI values were not different depending on AF presentation (paroxysmal AF, 98 ± 9; persistent AF, 100 ± 9) or on cardiac rhythm (sinus rhythm, 97 ± 7; AF,101 ± 10). In all PVs, ECI was significantly reduced during and after ablation (ECI during RF, 56 ± 15; ECI after RF, 72 ± 16; p < 0.001). A mean reduction of 32.2% during RF delivery and 25.4% immediately after RF discontinuation compared with baseline ECI was observed. Successful PV isolation is associated with a significant decrease in ECI of at least 20 %. This may be used as a surrogate marker of effective lesion in AF ablation.

  5. Discrete prepotential as an indicator of successful ablation in patients with coronary cusp ventricular arrhythmia.

    PubMed

    Hachiya, Hitoshi; Yamauchi, Yasuteru; Iesaka, Yoshito; Yagishita, Atsuhiko; Sasaki, Takeshi; Higuchi, Koji; Kawabata, Mihoko; Sugiyama, Koji; Tanaka, Yasuaki; Kusa, Shigeki; Nakamura, Hiroaki; Miyazaki, Shinsuke; Taniguchi, Hiroshi; Isobe, Mitsuaki; Hirao, Kenzo

    2013-10-01

    Although coronary cusp (CC) ventricular arrhythmia (VA) can be treated by catheter ablation, reliable indicators of successful ablation sites have not been fully identified. This study comprised 392 patients undergoing radiofrequency catheter ablation for outflow tract-VA at 3 institutions from January 2007 to August 2012. The successful ablation site was on the left CC or right CC in 35 (8.9%) of the 392 patients. In 9 (26%) of these 35 patients, a discrete prepotential was recognized, 5 of whom had left CC-VAs and 4 of whom had right CC-VAs. Radiofrequency catheter ablation was successful at the site of the prepotential in all 9 of these patients. The duration of the isoelectric line between the end of the discrete prepotential and the onset of the ventricular electrogram was 27±13 ms. The time from onset of the discrete prepotential at the successful ablation site on the CC to the QRS onset (activation time) was 69±20 ms (range, 50-98 ms). Pace mapping was graded as excellent at the successful ablation site in only 1 patient. No discrete prepotential was recorded in any successful right outflow tract-VA ablation case in this study. A discrete prepotential was seen in 9 (26%) of 35 patients with CC-VA. In left and right CC-VA, the site of a discrete prepotential with ≥50 ms activation time may indicate a successful ablation site.

  6. Electrophysiological Rotor Ablation in In-Silico Modeling of Atrial Fibrillation: Comparisons with Dominant Frequency, Shannon Entropy, and Phase Singularity.

    PubMed

    Hwang, Minki; Song, Jun-Seop; Lee, Young-Seon; Li, Changyong; Shim, Eun Bo; Pak, Hui-Nam

    2016-01-01

    Although rotors have been considered among the drivers of atrial fibrillation (AF), the rotor definition is inconsistent. We evaluated the nature of rotors in 2D and 3D in- silico models of persistent AF (PeAF) by analyzing phase singularity (PS), dominant frequency (DF), Shannon entropy (ShEn), and complex fractionated atrial electrogram cycle length (CFAE-CL) and their ablation. Mother rotor was spatiotemporally defined as stationary reentries with a meandering tip remaining within half the wavelength and lasting longer than 5 s. We generated 2D- and 3D-maps of the PS, DF, ShEn, and CFAE-CL during AF. The spatial correlations and ablation outcomes targeting each parameter were analyzed. 1. In the 2D PeAF model, we observed a mother rotor that matched relatively well with DF (>9 Hz, 71.0%, p<0.001), ShEn (upper 2.5%, 33.2%, p<0.001), and CFAE-CL (lower 2.5%, 23.7%, p<0.001). 2. The 3D-PeAF model also showed mother rotors that had spatial correlations with DF (>5.5 Hz, 39.7%, p<0.001), ShEn (upper 8.5%, 15.1%, p <0.001), and CFAE (lower 8.5%, 8.0%, p = 0.002). 3. In both the 2D and 3D models, virtual ablation targeting the upper 5% of the DF terminated AF within 20 s, but not the ablations based on long-lasting PS, high ShEn area, or lower CFAE-CL area. Mother rotors were observed in both 2D and 3D human AF models. Rotor locations were well represented by DF, and their virtual ablation altered wave dynamics and terminated AF.

  7. Reversion of left ventricular systolic dysfunction and abnormal stress test: by catheter ablation, in a patient with Wolff-Parkinson-White syndrome from Para-Hisian Kent bundle.

    PubMed

    Tu, Chung-Ming; Chu, Kai-Ming; Cheng, Cheng-Chung; Cheng, Shu-Mung; Lin, Wei-Shiang

    2010-01-01

    The diagnosis of Wolff-Parkinson-White syndrome is typically reserved for patients who experience ventricular pre-excitation and symptoms that are related to paroxysmal supraventricular tachycardia, such as chest pain, dyspnea, dizziness, palpitations, or syncope. Herein, we report the case of a 38-year-old woman who presented at our outpatient department because of exercise intolerance. Cardiac auscultation revealed a grade 2/6 pansystolic murmur over the left lower sternal border. Twelve-lead electrocardiography showed sinus rhythm at a rate of 76 beats/min, with a significant delta wave. Transthoracic echocardiography revealed abnormal left ventricular systolic function. The results of a thallium stress test were also abnormal. Coronary artery disease was suspected; however, coronary angiography yielded normal results. Electrophysiologic study revealed a para-Hisian Kent bundle and a dual atrioventricular nodal pathway. After radiofrequency catheter ablation was performed, the patient's left ventricular function improved and her symptoms disappeared. In Wolff-Parkinson-White syndrome, left ventricular systolic dyssynchrony can yield abnormal findings on echocardiography and thallium scanning--even in persons who have no cardiovascular risk factors. Physicians who are armed with this knowledge can avoid performing coronary angiography unnecessarily. Catheter ablation can reverse the dyssynchrony of the ventricle and improve the patient's symptoms.

  8. High intensity focused ultrasound ablation for atrial fibrillation: results from the National Spanish Registry.

    PubMed

    Reyes, Guillermo; Ruyra, Xavier; Valderrama, Francisco; Jimenez, Antonio; Duran, Dario; Perez, Enrique; Daroca, Tomas; Moya, Javier; Ramirez, Ulises; Aldamiz, Gonzalo

    2016-10-01

    A National Spanish Registry to compile all patients treated with high intensity focused ultrasound (HIFU) energy for atrial fibrillation (AF) was created to evaluate the safety and efficacy of AF surgical ablation. A national Spanish registry was created, and ten hospitals using HIFU to ablate AF joined it. A total of 412 patients undergoing cardiac surgery between 2006 and February 2013 were included. AF was divided between paroxysmal AF (33%) and persistent AF (67%) with a mean AF duration of 29.3±108.2 months. Mean left atrial diameter was 51.2±6.5 mm. Mean underlying heart disease were aortic valve disease (49.3%), ischemic disease (25.2%) and mitral disease (33.2%) Clinical follow-up of patients and a 6 months postoperative echocardiogram were performed in all patients. A pacemaker implantation was needed in 4.9% of patients with a perioperative stroke in 2.5%. Rhythm at discharge from hospital was sinus rhythm in 58%, AF in 35.9% and atrial flutter in 0.8% of patients. Sinus rhythm restoration at 6, 12, 24 and 36 months follow-up was achieved in 66.1%, 63.8%, 63.9% and 45.9% of patients respectively. Multivariate analysis showed paroxysmal AF and sinus rhythm restoration in the operating theatre as factors related to sinus rhythm long term restoration. The Spanish national registry showed an efficacy of AF ablation with the HIFU Epicor system of 66.1%, 63.8%, 63.9% and 45.9% at 6, 12, 24 and 36 months follow-up. There were no device-related complications.

  9. Value of an old school approach: safety and long-term success of radiofrequency current catheter ablation of atrioventricular nodal reentrant tachycardia in children and young adolescents.

    PubMed

    Siebels, Henrike; Sohns, Christian; Nürnberg, Jan-Hendrik; Siebels, Jürgen; Langes, Klaus; Hebe, Joachim

    2018-05-15

    Radiofrequency current energy (RFC) ablation is still considered as the gold standard for atrioventricular nodal reentrant tachycardia (AVNRT). Success-rates for AVNRT ablation vary irrespective of the ablation technology and strategy. This study aimed to access safety, efficacy, and long-term outcome of RFC catheter ablation for the treatment of AVNRT in children and adolescents aged < 19 years with special focus on modulation versus ablation of the AV nodal slow pathway (SP). A total number of 1143 patients (pts) < 19 years were referred for invasive electrophysiological testing due to paroxysmal supraventricular tachycardia (SVT). Diagnosis of AVNRT was confirmed in 412 pts, and RFC-guided ablation was attempted in 386 pts (age 13.0 ± 3.5 years). No permanent complications were observed. RFC application resulted in SP-ablation in 171/386 (44.3%) and in SP modulation in 208/386 (53.9%) children, whereas attempts for RFC treatment failed in 7 pts. Follow-up was completed for 396/412 patients (96.1%). Within a mean follow-up period of 54.9 ± 39.7 months, in 51/379 pts (13.5%) AVNRT recurrence was observed. The median time until tachycardia recurrence was 19.5 months. No difference for AVNRT recurrence was found comparing SP ablation versus SP modulation (p > 0.05), whereas the recurrence rate was significantly higher in patients with non-inducible SVT and therefore empiric SP treatment as compared to patients with inducible AVNRT (p = 0.01). RFC-guided ablation for AVNRT in children and adolescents is safe and leads to an acceptable long-term freedom from recurrences. SP modulation and SP ablation resulted in comparable acute and long-term success rates. Late AVNRT recurrences can occur even after years of freedom from tachycardia-related symptoms.

  10. Outcomes after cryoablation vs. radiofrequency in patients with paroxysmal atrial fibrillation: impact of pulmonary veins anatomy.

    PubMed

    Khoueiry, Z; Albenque, J-P; Providencia, R; Combes, S; Combes, N; Jourda, F; Sousa, P A; Cardin, C; Pasquie, J-L; Cung, T T; Massin, F; Marijon, E; Boveda, S

    2016-09-01

    Pulmonary vein isolation is the mainstay of treatment in catheter ablation of paroxysmal atrial fibrillation (AF). Cryoballoon ablation has been introduced more recently than radiofrequency ablation, the standard technique in most centres. Pulmonary veins frequently display anatomical variants, which may compromise the results of cryoballoon ablation. We aimed to evaluate the mid-term outcomes of cryoballoon ablation in an unselected population with paroxysmal AF from an anatomical viewpoint. Consecutive patients with paroxysmal AF who underwent a first procedure of cryoballoon ablation or radiofrequency were enrolled in this single-centre study. All patients underwent systematic standardized follow-up. Comparisons between radiofrequency and cryoballoon ablation (Arctic Front™ or Arctic Front Advance™) were performed regarding safety and efficacy endpoints, according to pulmonary vein (PV) anatomical variants. A total of 687 patients were enrolled (376 radiofrequency and 311 cryoballoon ablation). Baseline characteristics and distribution of PV anatomical variants were generally similar in the groups. After a mean follow-up of 14 ± 8 months, there was no difference in the incidence of relapse (17.0% cryoballoon ablation vs. 14.1% radiofrequency, P = 0.25). We observed no interaction of PV anatomical variants on mid-term procedural success. Our findings suggest that mid-term outcomes of cryoballoon ablation for paroxysmal AF ablation are similar to those of radiofrequency, regardless of PV anatomy. The presence of anatomical variants of PVs should not discourage the referral of patients with paroxysmal AF for cryoballoon ablation. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2016. For permissions please email: journals.permissions@oup.com.

  11. Randomized ablation strategies for the treatment of persistent atrial fibrillation: RASTA study.

    PubMed

    Dixit, Sanjay; Marchlinski, Francis E; Lin, David; Callans, David J; Bala, Rupa; Riley, Michael P; Garcia, Fermin C; Hutchinson, Mathew D; Ratcliffe, Sarah J; Cooper, Joshua M; Verdino, Ralph J; Patel, Vickas V; Zado, Erica S; Cash, Nancy R; Killian, Tony; Tomson, Todd T; Gerstenfeld, Edward P

    2012-04-01

    The single-procedure efficacy of pulmonary vein isolation (PVI) is less than optimal in patients with persistent atrial fibrillation (AF). Adjunctive techniques have been developed to enhance single-procedure efficacy in these patients. We conducted a study to compare 3 ablation strategies in patients with persistent AF. Subjects were randomized as follows: arm 1, PVI + ablation of non-PV triggers identified using a stimulation protocol (standard approach); arm 2, standard approach + empirical ablation at common non-PV AF trigger sites (mitral annulus, fossa ovalis, eustachian ridge, crista terminalis, and superior vena cava); or arm 3, standard approach + ablation of left atrial complex fractionated electrogram sites. Patients were seen at 6 weeks, 6 months, and 1 year; transtelephonic monitoring was performed at each visit. Antiarrhythmic drugs were discontinued at 3 to 6 months. The primary study end point was freedom from atrial arrhythmias off antiarrhythmic drugs at 1 year after a single-ablation procedure. A total of 156 patients (aged 59±9 years; 136 males; AF duration, 47±50 months) participated (arm 1, 55 patients; arm 2, 50 patients; arm 3, 51 patients). Procedural outcomes (procedure, fluoroscopy, and PVI times) were comparable between the 3 arms. More lesions were required to target non-PV trigger sites than a complex fractionated electrogram (33±9 versus 22±9; P<0.001). The primary end point was achieved in 71 patients and was worse in arm 3 (29%) compared with arm 1 (49%; P=0.04) and arm 2 (58%; P=0.004). These data suggest that additional substrate modification beyond PVI does not improve single-procedure efficacy in patients with persistent AF. URL: http://www.clinicaltrials.gov. Unique identifier: NCT00379301.

  12. Atrial Tachycardias Following Atrial Fibrillation Ablation

    PubMed Central

    Sághy, László; Tutuianu, Cristina; Szilágyi, Judith

    2015-01-01

    One of the most important proarrhythmic complications after left atrial (LA) ablation is regular atrial tachycardia (AT) or flutter. Those tachycardias that occur after atrial fibrillation (AF) ablation can cause even more severe symptoms than those from the original arrhythmia prior to the index ablation procedure since they are often incessant and associated with rapid ventricular response. Depending on the method and extent of LA ablation and on the electrophysiological properties of underlying LA substrate, the reported incidence of late ATs is variable. To establish the exact mechanism of these tachycardias can be difficult and controversial but correlates with the ablation technique and in the vast majority of cases the mechanism is reentry related to gaps in prior ablation lines. When tachycardias occur, conservative therapy usually is not effective, radiofrequency ablation procedure is mostly successful, but can be challenging, and requires a complex approach. PMID:25308808

  13. Renal denervation using catheter-based radiofrequency ablation with temperature control: renovascular safety profile and underlying mechanisms in a hypertensive canine model.

    PubMed

    Li, Huijie; Yu, Hang; Zeng, Chunyu; Fang, Yuqiang; He, Duofen; Zhang, Xiaoqun; Wen, Chunlan; Yang, Chengming

    2015-01-01

    Renal denervation is a novel method for hypertension treatment. In this study, we aimed to investigate the safety and efficacy of radiofrequency ablation (RFA) at ablation temperatures of 45 °C or 50 °C and its possible mechanisms. A hypertensive canine model was established by abdominal aortic constriction in 20 healthy hybrid dogs. These dogs were then randomly assigned to the treatment and the control groups, with dogs in the treatment group further randomly assigned to receive RFA at ablation temperatures of 45 °C or 50 °C. In the treatment group, RFA was performed at 1 month after modeling; renal angiography was performed at 2 months after ablation. The arterial vessels of the dogs were examined histologically with hematoxylin and eosin staining. Changes in blood pressure in the foreleg and whole-body norepinephrine spillover rate were also assessed. No arterial stenosis, dissection, thrombosis or other abnormalities were detected in the treated vessels by renal angiography, yet histology results showed minimal to mild renal arterial injury. Renal denervation resulted in a marked decrease in the whole-body norepinephrine spillover rate (p < 0.05) in addition to significantly reducing blood pressure (p < 0.05), with no significant differences detected between the 45 °C and 50 °C subgroups for both (p > 0.05). Renal denervation can be performed without acute major adverse events, using catheter-based RFA with temperature control. The procedure was feasible in reducing blood pressure by at least partially inhibiting sympathetic drive and systemic sympathetic outflow.

  14. Electrophysiological Rotor Ablation in In-Silico Modeling of Atrial Fibrillation: Comparisons with Dominant Frequency, Shannon Entropy, and Phase Singularity

    PubMed Central

    Hwang, Minki; Song, Jun-Seop; Lee, Young-Seon; Li, Changyong; Shim, Eun Bo; Pak, Hui-Nam

    2016-01-01

    Background Although rotors have been considered among the drivers of atrial fibrillation (AF), the rotor definition is inconsistent. We evaluated the nature of rotors in 2D and 3D in- silico models of persistent AF (PeAF) by analyzing phase singularity (PS), dominant frequency (DF), Shannon entropy (ShEn), and complex fractionated atrial electrogram cycle length (CFAE-CL) and their ablation. Methods Mother rotor was spatiotemporally defined as stationary reentries with a meandering tip remaining within half the wavelength and lasting longer than 5 s. We generated 2D- and 3D-maps of the PS, DF, ShEn, and CFAE-CL during AF. The spatial correlations and ablation outcomes targeting each parameter were analyzed. Results 1. In the 2D PeAF model, we observed a mother rotor that matched relatively well with DF (>9 Hz, 71.0%, p<0.001), ShEn (upper 2.5%, 33.2%, p<0.001), and CFAE-CL (lower 2.5%, 23.7%, p<0.001). 2. The 3D-PeAF model also showed mother rotors that had spatial correlations with DF (>5.5 Hz, 39.7%, p<0.001), ShEn (upper 8.5%, 15.1%, p <0.001), and CFAE (lower 8.5%, 8.0%, p = 0.002). 3. In both the 2D and 3D models, virtual ablation targeting the upper 5% of the DF terminated AF within 20 s, but not the ablations based on long-lasting PS, high ShEn area, or lower CFAE-CL area. Conclusion Mother rotors were observed in both 2D and 3D human AF models. Rotor locations were well represented by DF, and their virtual ablation altered wave dynamics and terminated AF. PMID:26909492

  15. Rapid recovery from congestive heart failure following successful radiofrequency catheter ablation in a patient with late onset of Wolff-Parkinson-White syndrome.

    PubMed

    Yodogawa, Kenji; Ono, Norihiko; Seino, Yoshihiko

    2012-01-01

    A 56-year-old man was admitted because of palpitations and dyspnea. A 12-lead electrocardiogram showed irregular wide QRS complex tachycardia with a slur at the initial portion of the QRS complex. He had preexisting long-standing persistent atrial fibrillation, but early excitation syndrome had never been noted. Chest X-ray showed heart enlargement and pulmonary congestion. He was diagnosed with late onset of Wolff-Parkinson-White syndrome, and congestive heart failure was probably caused by rapid ventricular response of atrial fibrillation through the accessory pathway. Emergency catheter ablation for the accessory pathway was undertaken, and heart failure was dramatically improved.

  16. Optimal contact forces to minimize cardiac perforations before, during, and/or after radiofrequency or cryothermal ablations.

    PubMed

    Quallich, Stephen G; Van Heel, Michael; Iaizzo, Paul A

    2015-02-01

    Catheter perforations remain a major clinical concern during ablation procedures for treatment of atrial arrhythmias and may lead to life-threatening cardiac tamponade. Radiofrequency (RF) ablation alters the biomechanical properties of cardiac tissue, ultimately allowing for perforation to occur more readily. Studies on the effects of cryoablation on perforation force as well as studies defining the perforation force of human tissue are limited. The purpose of this study was to investigate the required force to elicit perforation of cardiac atrial tissue after or during ablation procedures. Effects of RF or cryothermal ablations on catheter perforation forces for both swine (n = 83 animals, 530 treatments) and human (n = 8 specimens, 136 treatments) cardiac tissue were investigated. Overall average forces resulting in perforation of healthy unablated tissue were 406g ± 170g for swine and 591g ± 240g for humans. Post-RF ablation applications considerably reduced these forces to 246g ± 118g for swine and 362 ± 185g for humans (P <.001). Treatments with cryoablation did not significantly alter forces required to induce perforations. Decreasing catheter sizes resulted in a reduction in forces required to perforate the atrial wall (P <.001). Catheter perforations occurred over an array of contact forces with a minimum of 38g being observed. The swine model likely underestimates the required perforation forces relative to those of human tissues. We provide novel insights related to the comparative effects of RF and cryothermal ablations on the potential for inducing undesired punctures, with RF ablation reducing perforation force significantly. These data are insightful for physicians performing ablation procedures as well as for medical device designers. Copyright © 2015 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  17. Catheter ablation of fatal ventricular tachyarrhythmias storm in acute coronary syndrome--role of Purkinje fiber network.

    PubMed

    Enjoji, Yoshihisa; Mizobuchi, Masahiro; Muranishi, Hiromi; Miyamoto, Chinae; Utsunomiya, Makoto; Funatsu, Atsushi; Kobayashi, Tomoko; Nakamura, Shigeru

    2009-12-01

    Ventricular fibrillation (VF) or ventricular tachycardia (VT) storm is a life-threatening arrhythmia. Antiarrhythmic drugs (AADs) are not necessarily effective to rescue life from such conditions. Catheter ablation (CA) targeting triggering premature ventricular contractions (PVCs) of VF or VT that originates from Purkinje fiber network (PFN) is reported to be effective, especially in idiopathic patients. However, in condition of acute coronary syndrome (ACS), the efficacy of CA is not well understood. To clarify the usefulness of CA as an alternative way to AADs, we performed CA in four patients with VF or VT storm. The Purkinje potential was seen just before the myocardial ventricular wave during sinus rhythm that became more prominent and double components during the initiating PVC at the targeted area. Following CA, spontaneous episodes of VF or VT were no longer observed. CA is an efficacious way to bail out PFN-related VF or VT storm even in ACS.

  18. Radiofrequency ablation vs antiarrhythmic drugs as first-line treatment of paroxysmal atrial fibrillation (RAAFT-2): a randomized trial.

    PubMed

    Morillo, Carlos A; Verma, Atul; Connolly, Stuart J; Kuck, Karl H; Nair, Girish M; Champagne, Jean; Sterns, Laurence D; Beresh, Heather; Healey, Jeffrey S; Natale, Andrea

    2014-02-19

    Atrial fibrillation (AF) is the most common rhythm disorder seen in clinical practice. Antiarrhythmic drugs are effective for reduction of recurrence in patients with symptomatic paroxysmal AF. Radiofrequency ablation is an accepted therapy in patients for whom antiarrhythmic drugs have failed; however, its role as a first-line therapy needs further investigation. To compare radiofrequency ablation with antiarrhythmic drugs (standard therapy) in treating patients with paroxysmal AF as a first-line therapy. A randomized clinical trial involving 127 treatment-naive patients with paroxysmal AF were randomized at 16 centers in Europe and North America to received either antiarrhythmic therapy or ablation. The first patient was enrolled July 27, 2006; the last patient, January 29, 2010. The last follow-up was February 16, 2012. Sixty-one patients in the antiarrhythmic drug group and 66 in the radiofrequency ablation group were followed up for 24 months. The time to the first documented atrial tachyarrhythmia of more than 30 seconds (symptomatic or asymptomatic AF, atrial flutter, or atrial tachycardia), detected by either scheduled or unscheduled electrocardiogram, Holter, transtelephonic monitor, or rhythm strip, was the primary outcome. Secondary outcomes included symptomatic recurrences of atrial tachyarrhythmias and quality of life measures assessed by the EQ-5D tool. Forty-four patients (72.1%) in the antiarrhythmic group and in 36 patients (54.5%) in the ablation group experienced the primary efficacy outcome (hazard ratio [HR], 0.56 [95% CI, 0.35-0.90]; P = .02). For the secondary outcomes, 59% in the drug group and 47% in the ablation group experienced the first recurrence of symptomatic AF, atrial flutter, atrial tachycardia (HR, 0.56 [95% CI, 0.33-0.95]; P = .03). No deaths or strokes were reported in either group; 4 cases of cardiac tamponade were reported in the ablation group. In the standard treatment group, 26 patients (43%) underwent ablation

  19. Toward guidance of epicardial cardiac radiofrequency ablation therapy using optical coherence tomography

    NASA Astrophysics Data System (ADS)

    Fleming, Christine P.; Quan, Kara J.; Rollins, Andrew M.

    2010-07-01

    Radiofrequency ablation (RFA) is the standard of care to cure many cardiac arrhythmias. Epicardial ablation for the treatment of ventricular tachycardia has limited success rates due in part to the presence of epicardial fat, which prevents proper rf energy delivery, inadequate contact of ablation catheter with tissue, and increased likelihood of complications with energy delivery in close proximity to coronary vessels. A method to directly visualize the epicardial surface during RFA could potentially provide feedback to reduce complications and titrate rf energy dose by detecting critical structures, assessing probe contact, and confirming energy delivery by visualizing lesion formation. Currently, there is no technology available for direct visualization of the heart surface during epicardial RFA therapy. We demonstrate that optical coherence tomography (OCT) imaging has the potential to fill this unmet need. Spectral domain OCT at 1310 nm is employed to image the epicardial surface of freshly excised swine hearts using a microscope integrated bench-top scanner and a forward imaging catheter probe. OCT image features are observed that clearly distinguish untreated myocardium, ablation lesions, epicardial fat, and coronary vessels, and assess tissue contact with catheter-based imaging. These results support the potential for real-time guidance of epicardial RFA therapy using OCT imaging.

  20. Endurance Sport Activity and Risk of Atrial Fibrillation – Epidemiology, Proposed Mechanisms and Management

    PubMed Central

    Vicedomini, Gabriele; Pappone, Carlo

    2014-01-01

    There is evidence for a higher prevalence of atrial fibrillation (AF) in athletes engaged in long-term endurance sports training compared with the general population. Although atrial anatomic adaptations, alterations in autonomic nervous system, chronic systemic inflammation and fibrosis have been proposed as potential mechanisms, they remain speculative. Medical therapy with long-term antiarrhythmic agents or ‘pill in the pocket’ medications is hampered by limitations, such as sports eligibility and interference with exercise tolerance. AF ablation represents a valid therapeutic option with results similar to these achieved in other patients. Nevertheless, further clinical trials are needed to confirm whether endurance sport practice affects the maintenance of sinus rhythm following catheter ablation of AF. PMID:26835059

  1. Designing Comparative Effectiveness Trials of Surgical Ablation for Atrial Fibrillation: Experience of the Cardiothoracic Surgical Trials Network

    PubMed Central

    Gillinov, A. Marc; Argenziano, Michael; Blackstone, Eugene H.; Iribarne, Alexander; DeRose, Joseph J.; Ailawadi, Gorav; Russo, Mark J.; Ascheim, Deborah D.; Parides, Michael K.; Rodriguez, Evelio; Bouchard, Denis; Taddei-Peters, Wendy C.; Geller, Nancy L.; Acker, Michael A.; Gelijns, Annetine C.

    2013-01-01

    Background Since the introduction of the cut-and-sew Cox-Maze procedure for atrial fibrillation (AF) there has been substantial innovation in techniques for ablation. Use of alternate energy sources for ablation simplified the procedure and has resulted in dramatic increase in the number of AF patients treated by surgical ablation. Despite its increasingly widespread adoption, there is lack of rigorous clinical evidence to establish this as an effective clinical therapy. Methods and Results This paper describes a comparative effectiveness randomized trial, supported by the Cardiothoracic Surgical Trials Network, of surgical ablation with left atrial appendage (LAA) closure versus LAA closure alone in patients with persistent and longstanding persistent AF undergoing mitral valve surgery. Nested within this trial, is a further randomized comparison of 2 different lesions sets: pulmonary vein isolation and full Maze lesion set. This paper addresses trial design challenges, including how to best characterize the target population, operationalize freedom from AF as a primary endpoint, account for the impact of anti-arrhythmic drugs, and measure and analyze secondary endpoints, such as post-operative AF load. Conclusions This paper concludes by discussing how insights that emerge from this trial may affect surgical practice and guide future research in this area. PMID:21616507

  2. Insights into energy delivery to myocardial tissue during radiofrequency ablation through application of the first law of thermodynamics.

    PubMed

    Bunch, T Jared; Day, John D; Packer, Douglas L

    2009-04-01

    The approach to catheter-based radiofrequency ablation of atrial fibrillation has evolved, and as a consequence, more energy is delivered in the posterior left atrium, exposing neighboring tissue to untoward thermal injury. Simultaneously, catheter technology has advanced to allow more efficient energy delivery into the myocardium, which compounds the likelihood of collateral injury. This review focuses on the basic principles of thermodynamics as they apply to energy delivery during radiofrequency ablation. These principles can be used to titrate energy delivery and plan ablative approaches in an effort to minimize complications during the procedure.

  3. Predictors of cerebral microembolization during phased radiofrequency ablation of atrial fibrillation: analysis of biophysical parameters from the ablation generator.

    PubMed

    Nagy-Balo, Edina; Kiss, Alexandra; Condie, Catherine; Stewart, Mark; Edes, Istvan; Csanadi, Zoltan

    2014-06-01

    Pulmonary vein isolation with phased radiofrequency current and use of a pulmonary vein ablation catheter (PVAC) has recently been associated with a high incidence of clinically silent brain infarcts on diffusion-weighted magnetic resonance imaging and a high microembolic signal (MES) count detected by transcranial Doppler. The purpose of this study was to investigate the potential correlation between different biophysical parameters of energy delivery (ED) and MES generation during PVAC ablation. MES counts during consecutive PVAC ablations were recorded for each ED and time stamped for correlation with temperature, power, and impedance data from the GENius 14.4 generator. Additionally, catheter-tissue contact was characterized by the template deviation score, calculated by comparing the temperature curve with an ideal template representing good contact, and by the respiratory contact failure score, to quantify temperature variations indicative of intermittent contact due to respiration. A total of 834 EDs during 48 PVAC ablations were analyzed. A significant increase in MES count was associated with a lower average temperature, a temperature integral over 62°C, a higher average power, the total energy delivered, higher respiration and template deviation scores (P <.0001), and simultaneous ED to the most proximal and distal poles of the PVAC (P <.0001). MES generation during ablation is related to different indicators of poor electrode-tissue contact, the total power delivered, and the interaction between the most distal and the most proximal electrodes. Copyright © 2014. Published by Elsevier Inc.

  4. Determination of lesion size by ultrasound during radiofrequency catheter ablation.

    PubMed

    Awad, S; Eick, O

    2003-01-01

    The catheter tip temperature that is used to control the radiofrequency generator output poorly correlates to lesion size. We, therefore, evaluated lesions created in vitro using a B-mode ultrasound imaging device as a potential means to assess lesion generation during RF applications non-invasively. Porcine ventricular tissue was immersed in saline solution at 37 degrees C. The catheter was fixed in a holder and positioned in a parallel orientation to the tissue with an array transducer (7.5 MHz) app. 3 cm above the tissue. Lesions were produced either in a temperature controlled mode with a 4-mm tip catheter with different target temperatures (50, 60, 70 and 80 degrees C, 80 W maximum output) or in a power controlled mode (25, 50 and 75 W, 20 ml/min irrigation flow) using an irrigated tip catheter. Different contact forces (0.5 N, 1.0 N) were tested, and RF was delivered for 60 s. A total of 138 lesions was produced. Out of these, 128 could be identified on the ultrasound image. The lesion depth and volume was on average 4.1 +/- 1.6 mm and 52 +/- 53 mm3 as determined by ultrasound and 3.9 +/- 1.7 mm and 52 +/- 55 mm3 as measured thereafter, respectively. A linear correlation between the lesion size determined by ultrasound and that measured thereafter was demonstrated with a correlation coefficient of r = 0.87 for lesion depth and r = 0.93 for lesion volume. We conclude that lesions can be assessed by B-mode ultrasound imaging.

  5. Current status of the surgical treatment of atrial fibrillation.

    PubMed

    Geha, Alexander S; Abdelhady, Khaled

    2008-03-01

    Atrial fibrillation (AF) affects several million patients worldwide and is associated with a number of heart conditions, particularly coronary artery disease, rheumatic heart disease, hypertension, and congestive heart failure. The treatment of AF and its complications is quite costly. Atrial fibrillation usually results from multiple macro-re-entrant circuits in the left atrium. Very frequently, particularly in association with mitral valve disease, these circuits arise from the area of the junction of the pulmonary venous endothelium and the left atrial endocardium. Pharmacological therapy is at best 50% effective. Therapeutic options for AF include antiarrhythmic drugs, cardioversion, atrioventricular (A-V) node block, pacemaker insertion, and ablative surgery. In 1987, Cox developed an effective surgical procedure to achieve ablation. Current ablative procedures include the classic cut-and-sew Maze operation or a modification of it, namely through catheter ablation, namely, cryoablation, radiofrequency ablation (dry or irrigated), and other forms of ablation (e.g., laser, microwave). These procedures will be described, along with the indications, advantages and disadvantages of each. Special emphasis on the alternative means to cutting and sewing to achieve appropriate effective atrial scars will be stressed, and our experience with these approaches in 50 patients with AF and associated cardiac lesions and their outcomes is presented.

  6. Computationally efficient method for localizing the spiral rotor source using synthetic intracardiac electrograms during atrial fibrillation.

    PubMed

    Shariat, M H; Gazor, S; Redfearn, D

    2015-08-01

    Atrial fibrillation (AF), the most common sustained cardiac arrhythmia, is an extremely costly public health problem. Catheter-based ablation is a common minimally invasive procedure to treat AF. Contemporary mapping methods are highly dependent on the accuracy of anatomic localization of rotor sources within the atria. In this paper, using simulated atrial intracardiac electrograms (IEGMs) during AF, we propose a computationally efficient method for localizing the tip of the electrical rotor with an Archimedean/arithmetic spiral wavefront. The proposed method deploys the locations of electrodes of a catheter and their IEGMs activation times to estimate the unknown parameters of the spiral wavefront including its tip location. The proposed method is able to localize the spiral as soon as the wave hits three electrodes of the catheter. Our simulation results show that the method can efficiently localize the spiral wavefront that rotates either clockwise or counterclockwise.

  7. CoolLoop® First: A First In Man Study To Test A Novel Circular Cryoablation System In Paroxysmal Atrial Fibrillation.

    PubMed

    Stuehlinger, Markus; Hoenig, Simon; Spuller, Karin; Koman, Christian; Stoeger, Markus; Poelzl, Gerhard; Ulmer, Hanno; Pachinger, Otmar; Steinwender, Clemens

    2015-01-01

    Pulmonary vein (PV) isolation is the mainstay of catheter treatment of paroxysmal atrial fibrillation (AF). The CoolLoop® cryoablation catheter (AFreeze® GmbH; Innsbruck, Austria) was developed to create wide and complete circular lesions around the PVs. In this study we evaluated feasibility and safety of this novel ablation system in humans. 10 patients (6M/4F; 57.6±7.6y) with paroxysmal AF were included in 2 referral centers. The CoolLoop® catheter was positioned at each PV antrum using a steerable transseptal sheath. Subsequently, 2-6 double-freezes over 5min were performed at each vein and PV-isolation was assessed thereafter using a circular mapping catheter. During cryoablation of the right PVs, pacing was used to monitor phrenic nerve function. The CoolLoop® catheter could be successfully positioned at each PV. A mean of 5.6±1.8 cryoablations were performed in the LSPV, 5.2±1.6 in the LIPV, 6.3±2.5 in the RSPV and 5.4±1.6 in the RIPV, respectively. Mean procedure time was 251±60min and mean fluoroscopy time was 44.0±13.2min. 6 / 10 LSPV, 6 / 10 LIPV, 5 / 10 RSPV and 6 / 10 RIPV could be isolated exclusively using the novel cryoablation system. One patient developed groin hematoma and a brief episode of ST-elevation due to air embolism was observed in another subject. No other clinical complications occurred during 3 months of follow up. PV-isolation for paroxysmal atrial fibrillation using the CoolLoop® catheter is feasible and appears safe. Clinical long term efficacy still needs to be evaluated and will be compared with established catheters used for AF ablation.

  8. Accessory atrioventricular pathways refractory to catheter ablation: role of percutaneous epicardial approach.

    PubMed

    Scanavacca, Maurício Ibrahim; Sternick, Eduardo Back; Pisani, Cristiano; Lara, Sissy; Hardy, Carina; d'Ávila, André; Correa, Frederico Soares; Darrieux, Francisco; Hachul, Denise; Marcial, Miguel Barbero; Sosa, Eduardo A

    2015-02-01

    Epicardial mapping and ablation of accessory pathways through a subxiphoid approach can be an alternative when endocardial or epicardial transvenous mapping has failed. We reviewed acute and long-term follow-up of 21 patients (14 males) referred for percutaneous epicardial accessory pathway ablation. There was a median of 2 previous failed procedures. All patients were highly symptomatic, 8 had atrial fibrillation (3 with cardiac arrest) and 13 had frequent symptomatic episodes of atrioventricular reentrant tachycardia. Six patients (28.5%) had a successful epicardial ablation. Five patients (23.8%) underwent a successful repeated endocardial mapping, and ablation after epicardial mapping yielded no early activation site. Epicardial mapping was helpful in guiding endocardial ablation in 2 patients (9.5%), showing that the earliest activation was simultaneous at the epicardium and endocardium. Four patients (19%) underwent successful open-chest surgery after failing epicardial/endocardial ablation. Two patients (9.5%) remained controlled under antiarrhythmic drugs after unsuccessful endocardial/epicardial ablation. Two patients had a coronary sinus diverticulum and one a right atrium to right ventricle diverticulum. Three patients acquired postablation coronary sinus stenosis. There was no major complication related to pericardial access. Percutaneous epicardial approach is an alternative when conventional endocardial or transvenous epicardial ablation fails in the elimination of the accessory pathway. A new attempt by endocardial approach was successful in a significant number of patients. Open-chest surgery may be required in symptomatic cases refractory to endocardial-epicardial approach. © 2014 American Heart Association, Inc.

  9. Phrenic nerve protection via packing of gauze into the pericardial space during ablation of cristal atrial tachycardia in a child.

    PubMed

    Takahashi, Kazuhiro; Fuchigami, Tai; Nabeshima, Taisuke; Sashinami, Arata; Nakayashiro, Mami

    2016-03-01

    The success of catheter ablation of focal atrial tachycardia is limited by possible collateral damage to the phrenic nerve. Protection of the phrenic nerve is required. Here we present a case of a 9-year-old girl having a history of an unsuccessful catheter ablation of a focal atrial tachycardia near the crista terminalis (because of proximity of the phrenic nerve) who underwent a successful ablation by means of a novel technique for phrenic nerve protection: packing of gauze into the pericardial space. This method is a viable approach for patients with a failed endocardial ablation due to the proximity of the phrenic nerve.

  10. Beyond the Storm: Comparison of Clinical Factors, Arrhythmogenic Substrate, and Catheter Ablation Outcomes in Structural Heart Disease Patients With versus Those Without a History of Ventricular Tachycardia Storm.

    PubMed

    Kumar, Saurabh; Fujii, Akira; Kapur, Sunil; Romero, Jorge; Mehta, Nishaki K; Tanigawa, Shinichi; Epstein, Laurence M; Koplan, Bruce A; Michaud, Gregory F; John, Roy M; Stevenson, William G; Tedrow, Usha B

    2017-01-01

    Catheter ablation can be lifesaving in ventricular tachycardia (VT) storm, but the underlying substrate in patients with storm is not well characterized. We sought to compare the clinical factors, substrate, and outcomes differences in patients with sustained monomorphic VT who present for catheter ablation with VT storm versus those with a nonstorm presentation. Consecutive ischemic (ICM; n = 554) or nonischemic cardiomyopathy patients (NICM; n = 369) with a storm versus nonstorm presentation were studied (ICM storm 186; NICM storm 101). In ICM, storm compared with nonstorm patients had significantly lower left ventricular (LV) ejection fraction (EF), greater number of antiarrhythmic drug (AAD) failures, slower VTs, greater number of scarred LV segments, higher incidence of anterior, septal, and apical endocardial LV scar (all P < 0.05). However, outcomes in follow-up were similar (12-month ventricular arrhythmia [VA]-free survival: 51% vs. 52%, P = 0.6; survival free of death/transplant 75% vs. 87%, P = 0.7). In addition to the above differences, NICM storm patients were also older; however, the extent and distribution of scar was similar except for a higher incidence of lateral endocardial scar in storm patients (P = 0.05). VA-free survival (36% vs. 47%, P = 0.004) and survival free of death/transplant, however, were worse in NICM storm than nonstorm patients (72% vs. 88%, P = 0.001). NICM storm patients had worse VA-free survival than ICM storm patients. There are differences in clinical factors and scar patterns in patients undergoing VT ablation who present with VT storm versus those with a nonstorm presentation. Clinical outcomes are worse in NICM storm patients. © 2016 Wiley Periodicals, Inc.

  11. Right atrium positioning for exposure of right pulmonary veins during off-pump atrial fibrillation ablation.

    PubMed

    Suwalski, Grzegorz; Emery, Robert; Mróz, Jakub; Kaczejko, Kamil; Gryszko, Leszek; Cwetsch, Andrzej; Skrobowski, Andrzej

    2017-06-01

    Concomitant surgical ablation of atrial fibrillation (AF) is recommended for patients undergoing off-pump coronary revascularization in the presence of this arrhythmia. Achievement of optimal visualization of pulmonary veins while maintaining stable haemodynamic conditions is crucial for proper completion of the ablation procedure. This study evaluates the safety and feasibility of right atrial positioning using a suction-based cardiac positioner as opposed to compressive manoeuvres for exposure during off-pump surgical ablation for AF. Thirty-four consecutive patients underwent pulmonary vein isolation, ganglionated plexi ablation and left atrial appendage occlusion during off-pump coronary artery bypass grafting. Right atrial suction positioning was used to visualize right pulmonary veins. Safety and feasibility end points were analysed intraoperatively and in the early postoperative course. In all patients, right atrial positioning created optimal conditions to complete transverse and oblique sinus blunt dissection, correct placement of a bipolar ablation probe, detection and ablation of ganglionated plexi and conduction block assessment. In all patients, this entire right-sided ablation procedure was completed with a single exposure manoeuvre. Feasibility end points were achieved in all study patients. This report documents the safety and feasibility of right atrial exposure using a suction-based cardiac positioner to complete ablation for AF concomitant with off-pump coronary revascularization. This technique may be widely adopted to create stable haemodynamic conditions and optimal visualization of the right pulmonary veins. © The Author 2017. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  12. Radiofrequency ablation of fast ventricular tachycardia causing an ICD storm in an infant with hypertrophic cardiomyopathy.

    PubMed

    Ergul, Yakup; Ozyilmaz, Isa; Bilici, Meki; Ozturk, Erkut; Haydin, Sertaç; Guzeltas, Alper

    2018-04-01

    An implantable cardioverter defibrillator (ICD) storm involves very frequent arrhythmia episodes and ICD shocks, and it is associated with poor short-term and long-term prognosis. Radiofrequency catheter ablation can be used as an effective rescue treatment for patients with an ICD storm. To our knowledge, this is the first report of an infant with hypertrophic cardiomyopathy presenting with an ICD storm and undergoing successful radiofrequency catheter ablation salvage treatment for the fast left posterior fascicular ventricular tachycardia. © 2017 Wiley Periodicals, Inc.

  13. Multimodal Examination of Atrial Fibrillation Substrate: Correlation of Left Atrial Bipolar Voltage Using Multi-Electrode Fast Automated Mapping, Point-by-Point Mapping, and Magnetic Resonance Image Intensity Ratio.

    PubMed

    Zghaib, Tarek; Keramati, Ali; Chrispin, Jonathan; Huang, Dong; Balouch, Muhammad A; Ciuffo, Luisa; Berger, Ronald D; Marine, Joseph E; Ashikaga, Hiroshi; Calkins, Hugh; Nazarian, Saman; Spragg, David D

    2018-01-01

    Bipolar voltage mapping, as part of atrial fibrillation (AF) ablation, is traditionally performed in a point-by-point (PBP) approach using single-tip ablation catheters. Alternative techniques for fibrosis-delineation include fast-anatomical mapping (FAM) with multi-electrode circular catheters, and late gadolinium-enhanced magnetic-resonance imaging (LGE-MRI). The correlation between PBP, FAM, and LGE-MRI fibrosis assessment is unknown. In this study, we examined AF substrate using different modalities (PBP, FAM, and LGE-MRI mapping) in patients presenting for an AF ablation. LGE-MRI was performed pre-ablation in 26 patients (73% males, age 63±8years). Local image-intensity ratio (IIR) was used to normalize myocardial intensities. PBP- and FAM-voltage maps were acquired, in sinus rhythm, prior to ablation and co-registered to LGE-MRI. Mean bipolar voltage for all 19,087 FAM voltage points was 0.88±1.27mV and average IIR was 1.08±0.18. In an adjusted mixed-effects model, each unit increase in local IIR was associated with 57% decrease in bipolar voltage (p<0.0001). IIR of >0.74 corresponded to bipolar voltage <0.5 mV. A total of 1554 PBP-mapping points were matched to the nearest FAM-point. In an adjusted mixed-effects model, log-FAM bipolar voltage was significantly associated with log-PBP bipolar voltage (ß=0.36, p<0.0001). At low-voltages, FAM-mapping distribution was shifted to the left compared to PBP-mapping; at intermediate voltages, FAM and PBP voltages were overlapping; and at high voltages, FAM exceeded PBP-voltages. LGE-MRI, FAM and PBP-mapping show good correlation in delineating electro-anatomical AF substrate. Each approach has fundamental technical characteristics, the awareness of which allows proper assessment of atrial fibrosis.

  14. Investigating relationships between left atrial volume, symmetry, and sphericity

    NASA Astrophysics Data System (ADS)

    Menon, Prahlad G.; Nedios, Sotiris; Hindricks, Gerhard; Bollmann, Andreas

    2016-03-01

    Catheter ablation is a safe and effective therapy for drug-refractory patients symptomatic of atrial fibrillation (AF), with up to 80% of patients experiencing long-term arrhythmia-free survival. However, up to 20-40% of patients require more than one procedure in order to become arrhythmia-free. Therefore, appropriate patient selection is paramount to the effective implementation and long-term success of ablation therapy for patients with atrial fibrillation (AF). In this study, as a precursor to evaluating clinical significance of specific LA shape metrics as pre-procedural predictors of AF recurrence following ablative pulmonary vein isolation therapy, we report on a computational geometric analysis in a pilot cohort evaluating relationships between various patient-specific metrics of LA shape which might have such predictive value. This study specifically is focused on establishing the relationship between LA volume and sphericity, using a novel methodology for computing atrial sphericity based on regional shape.

  15. Non-fluoroscopic navigation systems for radiofrequency catheter ablation for supraventricular tachycardia reduce ionising radiation exposure.

    PubMed

    See, Jason; Amora, Jonah L; Lee, Sheldon; Lim, Paul; Teo, Wee Siong; Tan, Boon Yew; Ho, Kah Leng; Lee, Chee Wan; Ching, Chi-Keong

    2016-07-01

    The use of non-fluoroscopic systems (NFS) to guide radiofrequency catheter ablation (RFCA) for the treatment of supraventricular tachycardia (SVT) is associated with lower radiation exposure. This study aimed to determine if NFS reduces fluoroscopy time, radiation dose and procedure time. We prospectively enrolled patients undergoing RFCA for SVT. NFS included EnSiteTM NavXTM or CARTO® mapping. We compared procedure and fluoroscopy times, and radiation exposure between NFS and conventional fluoroscopy (CF) cohorts. Procedural success, complications and one-year success rates were reported. A total of 200 patients over 27 months were included and RFCA was guided by NFS for 79 patients; those with atrioventricular nodal reentrant tachycardia (AVNRT), left-sided atrioventricular reentrant tachycardia (AVRT) and right-sided AVRT were included (n = 101, 63 and 36, respectively). Fluoroscopy times were significantly lower with NFS than with CF (10.8 ± 11.1 minutes vs. 32.0 ± 27.5 minutes; p < 0.001). The mean fluoroscopic dose area product was also significantly reduced with NFS (NSF: 5,382 ± 5,768 mGy*cm2 vs. CF: 21,070 ± 23,311 mGy*cm2; p < 0.001); for all SVT subtypes. There was no significant reduction in procedure time, except for left-sided AVRT ablation (NFS: 79.2 minutes vs. CF: 116.4 minutes; p = 0.001). Procedural success rates were comparable (NFS: 97.5% vs. CF: 98.3%) and at one-year follow-up, there was no significant difference in the recurrence rates (NFS: 5.2% vs. CF: 4.2%). No clinically significant complications were observed in both groups. The use of NFS for RFCA for SVT is safe, with significantly reduced radiation dose and fluoroscopy time. Copyright © Singapore Medical Association.

  16. Remodeling of sinus node function after catheter ablation of right atrial flutter.

    PubMed

    Daoud, Emile G; Weiss, Raul; Augostini, Ralph S; Kalbfleisch, Steven J; Schroeder, Jason; Polsinelli, Georgia; Hummel, John D

    2002-01-01

    The purpose of this study was to investigate the effect of ablation of right atrial flutter upon sinus node function in humans. This study enrolled 35 patients. Twenty-four patients (16 men and 8 women; age 68 +/- 11 years) were referred for ablation of persistent atrial flutter (duration 8 +/- 11 months). After ablation, there was abnormal sinus node function defined as a corrected sinus node recovery time (CSNRT) > or = 550 msec. The control group consisted of 11 patients who were undergoing pacemaker implantation for sinus node disease but did not have a history of atrial dysrhythmias or ablation. Within 24 hours of ablation or pacemaker implantation, baseline maximal CSNRT was measured through a permanent pacemaker by AAI pacing at six cycle lengths: 600, 550, 500, 450, 400, and 350 msec. CSNRT then was measured in the same manner at 48 hours, 14 days, and 3 months after ablation/pacemaker implantation. P wave amplitude and duration, and percent atrial sensing also were assessed at the same intervals. For patients undergoing atrial flutter ablation, there was progressive temporal recovery of CSNRT (1,204 +/- 671 msec at baseline vs 834 +/- 380 msec at 3 months; P < 0.001) and a significant increase in the percent atrial sensing and P wave amplitude at 3 months compared with baseline (P < 0.001). In control subjects, there was no change in the CSNRT, percent atrial pacing, or P wave amplitude. After ablation of persistent atrial flutter, there is temporal recovery of CSNRT and increase in spontaneous atrial activity. These findings suggest that atrial flutter induces reversible changes in sinus node function.

  17. Real-time dominant frequency mapping and ablation of dominant frequency sites in atrial fibrillation with left-to-right frequency gradients predicts long-term maintenance of sinus rhythm.

    PubMed

    Atienza, Felipe; Almendral, Jesús; Jalife, José; Zlochiver, Sharon; Ploutz-Snyder, Robert; Torrecilla, Esteban G; Arenal, Angel; Kalifa, Jérôme; Fernández-Avilés, Francisco; Berenfeld, Omer

    2009-01-01

    Spectral analysis identifies localized sites of high-frequency activity during atrial fibrillation (AF). This study sought to determine the effectiveness of using real-time dominant frequency (DF) mapping for radiofrequency ablation of maximal DF (DFmax) sites and elimination of left-to-right frequency gradients in the long-term maintenance of sinus rhythm (SR) in AF patients. DF mapping was performed in 50 patients during ongoing AF (32 paroxysmal, 18 persistent), acquiring a mean of 117 +/- 38 points. Ablation was performed targeting DFmax sites, followed by circumferential pulmonary vein isolation. Ablation significantly reduced DFs (Hz) in the LA (7.9 +/- 1.4 vs. 5.7 +/- 1.3, P <.001), coronary sinus (CS) (5.7 +/- 1.1 vs. 5.3 +/- 1.2, P = .006), and RA (6.3 +/- 1.4 vs. 5.4 +/- 1.3, P <.001) abolishing baseline left-to-right atrial DF gradient (1.7 +/- 1.7 vs. 0.2 +/- 0.9; P <.001). Only a significant reduction in DFs in all chambers with a loss of the left-to-right atrial gradient after ablation was associated with a higher probability of long-term SR maintenance in both paroxysmal and persistent AF patients. After a mean follow-up of 9.3 +/- 5.4 months, 88% of paroxysmal and 56% of persistent AF patients were free of AF (P = .02). Ablation of DFmax sites was associated with a higher probability of remaining both free of arrhythmias (78% vs. 20%; P = .001) and free of AF (88% vs. 30%; P <.001). Radiofrequency ablation leading to elimination of LA-to-RA frequency gradients predicts long-term SR maintenance in AF patients.

  18. The prevalence of early repolarization in Wolff-Parkinson-White syndrome with a special reference to J waves and the effects of catheter ablation.

    PubMed

    Yagihara, Nobue; Sato, Akinori; Iijima, Kenichi; Izumi, Daisuke; Furushima, Hiroshi; Watanabe, Hiroshi; Irie, Tadanobu; Kaneko, Yoshiaki; Kurabayashi, Masahiko; Chinushi, Masaomi; Satou, Masahito; Aizawa, Yoshifusa

    2012-01-01

    We determined the prevalence of J waves in the electrocardiograms (ECG) of 120 patients with Wolff-Parkinson-White syndrome in comparison with J-wave prevalence in a control group of 1936 men and women with comparable demographic and ECG characteristics and with normal atrioventricular conduction. J waves were present only during manifest preexcitation in 22 of 120 patients (18.3%), disappearing after catheter ablation and suggesting that J waves were associated with the presence of preexcitation. J waves were present in 19 (15.8%) of 120 patients only after ablation, apparently having been masked by early depolarization of the preexcited myocardial region, and in 22 patients (18.3%), J waves were not altered significantly by preexcitation. Thus, the overall J-wave prevalence was 52.5% (63/120) and, excluding those apparently due to preexcitation, 34.8% (41/120), both substantially higher than the prevalence (11.5%) in the control group (P < .001 for both). The patients with J waves appearing only during preexcitation were younger, predominantly females. The presence of J waves after ablation was associated with a history of atrial fibrillation and shorter ventricular effective refractory period. It is concluded that the prevalence of J waves is high in patients with Wolff-Parkinson-White syndrome and is influenced by manifest preexcitation. Copyright © 2012 Elsevier Inc. All rights reserved.

  19. Arrhythmogenic substrate at the interventricular septum as a target site for radiofrequency catheter ablation of recurrent ventricular tachycardia in left dominant arrhythmogenic cardiomyopathy.

    PubMed

    Havranek, Stepan; Palecek, Tomas; Kovarnik, Tomas; Vitkova, Ivana; Psenicka, Miroslav; Linhart, Ales; Wichterle, Dan

    2015-03-10

    Left dominant arrhythmogenic cardiomyopathy (LDAC) is a rare condition characterised by progressive fibrofatty replacement of the myocardium of the left ventricle (LV) in combination with ventricular arrhythmias of LV origin. A thirty-five-year-old male was referred for evaluation of recurrent sustained monomorphic ventricular tachycardia (VT) of 200 bpm and right bundle branch block (RBBB) morphology. Cardiac magnetic resonance imaging showed late gadolinium enhancement distributed circumferentially in the epicardial layer of the LV free wall myocardium including the rightward portion of the interventricular septum (IVS). The clinical RBBB VT was reproduced during the EP study. Ablation at an LV septum site with absence of abnormal electrograms and a suboptimum pacemap rendered the VT of clinical morphology noninducible. Three other VTs, all of left bundle branch block (LBBB) pattern, were induced by programmed electrical stimulation. The regions corresponding to abnormal electrograms were identified and ablated at the mid-to-apical RV septum and the anteroseptal portion of the right ventricular outflow tract. No abnormalities were found at the RV free wall including the inferolateral peritricuspid annulus region. Histological examination confirmed the presence of abnormal fibrous and adipose tissue with myocyte reduction in endomyocardial samples taken from both the left and right aspects of the IVS. LDAC rarely manifests with sustained monomorphic ventricular tachycardia. In this case, several VTs of both RBBB and LBBB morphology were amenable to endocardial radiofrequency catheter ablation.

  20. Saphenous Venous Ablation with Hot Contrast in a Canine Model

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Prasad, Amit; Qian Zhong; Kirsch, David

    2008-01-15

    Purpose. To determine the feasibility, efficacy, and safety of thermal ablation of the saphenous vein with hot contrast medium. Methods. Twelve saphenous veins of 6 dogs were percutaneously ablated with hot contrast medium. In all animals, ablation was performed in the vein of one leg, followed by ablation in the contralateral side 1 month later. An occlusion balloon catheter was placed in the infragenicular segment of the saphenous vein via a jugular access to prevent unwanted thermal effects on the non-target segment of the saphenous vein. After inflation of the balloon, 10 ml of hot contrast medium was injected undermore » fluoroscopic control through a sheath placed in the saphenous vein above the ankle. A second 10 ml injection of hot contrast medium was made after 5 min in each vessel. Venographic follow-up of the ablated veins was performed at 1 month (n = 12) and 2 months (n = 6). Results. Follow-up venograms showed that all ablated venous segments were occluded at 1 month. In 6 veins which were followed up to 2 months, 4 (66%) remained occluded, 1 (16%) was partially patent, and the remaining vein (16%) was completely patent. In these latter 2 cases, an inadequate amount of hot contrast was delivered to the lumen due to a closed balloon catheter downstream which did not allow contrast to displace blood within the vessel. Discussion. Hot contrast medium thermal ablation of the saphenous vein appears feasible, safe, and effective in the canine model, provided an adequate amount of embolization agent is used.« less

  1. Contact force sensing for ablation of persistent atrial fibrillation: A randomized, multicenter trial.

    PubMed

    Conti, Sergio; Weerasooriya, Rukshen; Novak, Paul; Champagne, Jean; Lim, Hong Euy; Macle, Laurent; Khaykin, Yaariv; Pantano, Alfredo; Verma, Atul

    2018-02-01

    Impact of contact force sensing (CFS) on ablation of persistent atrial fibrillation (PeAF) is unknown. The purpose of the TOUCH AF (Therapeutic Outcomes Using Contact force Handling during Ablation of Persistent Atrial Fibrillation) randomized trial was to compare CFS-guided ablation to a CFS-blinded strategy. Patients (n = 128) undergoing first-time ablation for persistent AF were randomized to a CFS-guided vs CFS-blinded strategy. In the CFS-guided procedure, operators visualized real-time force data. In the blinded procedure, force data were hidden. Wide antral pulmonary vein isolation plus a roof line were performed. Patients were followed at 3, 6, 9, and 12 months with clinical visit, ECG, and 48-hour Holter monitoring. The primary endpoint was cumulative radiofrequency (RF) time for all procedures. Atrial arrhythmia >30 seconds after 3 months was a recurrence. PeAF was continuous for 26 weeks (interquartile range [IQR] 13-52), and left atrial size was 45 ± 5 mm. Force in the CFS-blinded and CFS-guided arms was 12 g [IQR 6-20] and 14 g [IQR 9-20] (P = .10), respectively. Total RF time did not differ between CFS-guided and CFS-blinded groups (49 ± 14 min vs 50 ± 20 min, respectively; P = .70). Single procedure freedom from atrial arrhythmia was 60% in the CFS-guided arm and 63% in the CFS-blinded arm off drugs. Lesions with gaps were associated with significantly less force (11.4 g [IQR 6-19] vs 13.2 g [IQR 8-20], respectively; P = .0007) and less force-time integral (174 gs [IQR 91-330] vs 210 gs [IQR 113-388], respectively; P <.001). CFS-guided ablation resulted in no difference to RF time or 12-month outcome. Lower force/force-time integral was associated with significantly more gaps. Copyright © 2017 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  2. Feasibility of implementation of a "simplified, No-X-Ray, no-lead apron, two-catheter approach" for ablation of supraventricular arrhythmias in children and adults.

    PubMed

    Stec, Sebastian; Śledź, Janusz; Mazij, Mariusz; Raś, Małgorzata; Ludwik, Bartosz; Chrabąszcz, Michał; Śledź, Arkadiusz; Banasik, Małgorzata; Bzymek, Magdalena; Młynarczyk, Krzysztof; Deutsch, Karol; Labus, Michał; Śpikowski, Jerzy; Szydłowski, Lesław

    2014-08-01

    Although the "near-zero-X-Ray" or "No-X-Ray" catheter ablation (CA) approach has been reported for treatment of various arrhythmias, few prospective studies have strictly used "No-X-Ray," simplified 2-catheter approaches for CA in patients with supraventricular tachycardia (SVT). We assessed the feasibility of a minimally invasive, nonfluoroscopic (MINI) CA approach in such patients. Data were obtained from a prospective multicenter CA registry of patients with regular SVTs. After femoral access, 2 catheters were used to create simple, 3D electroanatomic maps and to perform electrophysiologic studies. Medical staff did not use lead aprons after the first 10 MINI CA cases. A total of 188 patients (age, 45 ± 21 years; 17% <19 years; 55% women) referred for the No-X-Ray approach were included. They were compared to 714 consecutive patients referred for a simplified approach using X-rays (age, 52 ± 18 years; 7% <19 years; 55% women). There were 9 protocol exceptions that necessitated the use of X-rays. Ultimately, 179/188 patients underwent the procedure without fluoroscopy, with an acute success rate of 98%. The procedure times (63 ± 26 vs. 63 ± 29 minutes, P > 0.05), major complications (0% vs. 0%, P > 0.05) and acute (98% vs. 98%, P > 0.05) and long-term (93% vs. 94%, P > 0.05) success rates were similar in the "No-X-Ray" and control groups. Implementation of a strict "No-X-Ray, simplified 2-catheter" CA approach is safe and effective in majority of the patients with SVT. This modified approach for SVTs should be prospectively validated in a multicenter study. © 2014 Wiley Periodicals, Inc.

  3. Amiodarone and Catheter Ablation as Cardiac Resynchronization Therapy for Children with Dilated Cardiomyopathy and Wolff-Parkinson-White Syndrome

    PubMed Central

    Kim, Sung Hoon; Jeong, Soo In; Kang, I-Seok; Lee, Heung Jae

    2013-01-01

    Preexcitation by accessory pathways (APs) is known to cause dyssynchrony of the ventricle, related to ventricular dysfunction. Correction of ventricular dyssynchrony can improve heart failure in cases of dilated cardiomyopathy (DCMP) with preexcitation. Here, we report the first case of a child with DCMP and Wolff-Parkinson-White (WPW) syndrome treated with amiodarone and radiofrequency catheter ablation (RFCA) in Korea. A 7-year-old boy, who suffered from DCMP and WPW syndrome, showed improved left ventricular function and clinical functional class after treatment with amiodarone to eliminate preexcitation. QRS duration and left ventricular ejection fraction (LVEF) were inversely correlated with amiodarone dosage. After confirming the reduction of preexcitation effects in DCMP, successful RFCA of the right anterior AP resulted in LVEF improvement, along with the disappearance of preexcitation. Our findings suggest that ventricular dyssynchrony, caused by preexcitation in DCMP with WPW syndrome, can worsen ventricular function and amiodarone, as well as RFCA, which should be considered as a treatment option, even in young children. PMID:23407697

  4. Limited left atrial surgical ablation effectively treats atrial fibrillation but decreases left atrial function.

    PubMed

    Compier, Marieke G; Tops, Laurens F; Braun, Jerry; Zeppenfeld, Katja; Klautz, Robert J; Schalij, Martin J; Trines, Serge A

    2017-04-01

    Limited left atrial (LA) surgical ablation with bipolar radiofrequency is considered to be an effective procedure for treatment of atrial fibrillation (AF). We studied whether limited LA surgical ablation concomitant to cardiac surgery is able to maintain LA function. Thirty-six consecutive patients (age 66 ± 12 years, 53% male, 78% persistent AF) scheduled for valve surgery and/or coronary revascularization and concomitant LA surgical ablation were included. Epicardial pulmonary vein isolation (PVI) and additional endo-epicardial lines were performed using bipolar radiofrequency. An age- and gender-matched control group (n = 36, age 66 ± 9 years, 69% male, 81% paroxysmal AF) was selected from patients undergoing concomitant epicardial PVI only. Left atrial dimensions and function were assessed on two-dimensional echocardiography preoperatively and at 3- and 12-month follow-up. Sinus rhythm (SR) maintenance was 67% for limited LA ablation and 81% for PVI at 1-year follow-up (P = 0.18). Left atrial volume decreased from 72 ± 21 to 50 ± 14 mL (31%, P < 0.01) after limited LA ablation and from 65 ± 23 to 56 ± 20 mL (14%, P < 0.01) after PVI. Atrial transport function was restored in 54% of patients in SR after limited LA ablation compared with 100% of patients in SR after PVI. Atrial strain and contraction parameters (LA ejection fraction, A-wave velocity, reservoir function, and strain rate) significantly decreased after limited LA ablation. After PVI, strain and contraction parameters remained unchanged. Even limited LA ablation decreased LA volume, contraction, transport function, and compliance, indicating both reverse remodelling combined with significant functional deterioration. In contrast, surgical PVI decreased LA volume while function remained unchanged. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2016. For permissions please email: journals.permissions@oup.com.

  5. [Intravenous ablation of the atrio-ventricular junction in patients with supraventricular tachyarrhythmias].

    PubMed

    Drzewiecki, J; Trusz-Gluza, M; Wnuk-Wojnar, A; Jaklik, A; Czerwiński, C; Filipecki, A; Szydło, K; Ciemniewski, Z; Giec, L

    1993-01-01

    Since the first successful therapeutic DC ablation of the AV junction in 1986, we have treated 20 symptomatic patients with drug-refractory supraventricular tachyarrhythmias (average of 6 antiarrhythmic drugs prior to the ablation attempt). The primary rhythm disturbances necessitating ablation were: AV nodal reentrant tachycardia (50% of pts), atrial flutter or fibrillation, with an uncontrolled rapid ventricular response (40%), atrioventricular reentrant tachycardia using an accessory pathway (20%), atrial tachycardia (10%), and junctional reciprocating tachycardia (5%). Percutaneous catheter ablation of the AV junction was made by Gallagher's method. The USCI 4-polar catheter (7F) was used in 40% of pts, and bipolar Cordis catheter (5F) in the remaining 60%. 70% of pts received either one or two shocks, usually of 200 or 300 J during one session. Another 25% received stored cumulative energy from 800 to 1200 J (in two sessions), and one patient--1800 J (during three sessions). In 85% of pts, the immediate post-ablation conduction was third-degree AV block with the escape pacemaker, ranging from 20 to 50 beats/min., which was infra-His in 57%, and supra-His in 43% of pts. In 15% of pts were either first-degree AV block (10%) or normal AV conduction (5%). A His bundle deflection more than 0.2 mV was predictive of successful production of third-degree AV block. Except a mild and transient increase of indicating enzymes (CPK and CPK-MB) we did not observe any other serious complications directly related to the ablalation procedure. Follow-up study included 19 pts (time range from 2 to 56 months, mean 28).(ABSTRACT TRUNCATED AT 250 WORDS)

  6. Integration of intracardiac echocardiography and computed tomography during atrial fibrillation ablation: Combining ultrasound contours obtained from the right atrium and ventricular outflow tract.

    PubMed

    Nakamura, Kohki; Naito, Shigeto; Kaseno, Kenichi; Nakatani, Yosuke; Sasaki, Takehito; Anjo, Naofumi; Yamashita, Eiji; Kumagai, Koji; Funabashi, Nobusada; Kobayashi, Yoshio; Oshima, Shigeru

    2017-02-01

    We aimed to optimize the acquisition of the left atrial (LA) and pulmonary vein (PV) ultrasound contours for more accurate integration of intracardiac echocardiography (ICE) and computed tomography (CT) using the CARTO ® 3 system during atrial fibrillation (AF) ablation. Eighty-five AF patients underwent integration of ICE and CT using (1) the LA roof and posterior wall contours acquired from the right atrium (RA), (2) all LA/PV contours from the RA (Whole-RA-integration), (3) the LA roof/posterior wall contours from the RA and right ventricular outflow tract (RVOT) (Posterior-RA/RV-integration), and (4) all LA/PV contours from the RA and RVOT (Whole-RA/RV-integration). The integration accuracy was compared using the (1) surface registration error, (2) distances between the three-dimensional CT and eight specific sites on the anterior, posterior, superior, and inferior aspects of the right and left circumferential PV isolation lines, and (3) registration score: a score of 0 or 1 was assigned for whether or not each specific site was visually aligned with the CT, and summed for each method (0 best, 8 worst). Posterior-RA/RV-integration revealed a significantly lower surface registration error (1.30±0.15mm) than Whole-RA- and Whole-RA/RV-integration (p<0.001). The mean distances of the eight specific sites and the registration score for Posterior-RA/RV-integration (median 1.26mm and 2, respectively) were significantly smaller than those for the other integration approaches (p<0.001). Image integration with the LA roof and posterior wall contours acquired from the RA and RVOT may provide greater accuracy for catheter navigation with three-dimensional CT during AF ablation. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  7. Persistent atrial fibrillation vs paroxysmal atrial fibrillation: differences in management.

    PubMed

    Margulescu, Andrei D; Mont, Lluis

    2017-08-01

    Atrial fibrillation (AF) is the most common human arrhythmia. AF is a progressive disease, initially being nonsustained and induced by trigger activity, and progressing towards persistent AF through alteration of the atrial myocardial substrate. Treatment of AF aims to decrease the risk of stroke and improve the quality of life, by preventing recurrences (rhythm control) or controlling the heart rate during AF (rate control). In the last 20 years, catheter-based and, less frequently, surgical and hybrid ablation techniques have proven more successful compared with drug therapy in achieving rhythm control in patients with AF. However, the efficiency of ablation techniques varies greatly, being highest in paroxysmal and lowest in long-term persistent AF. Areas covered: In this review, we discuss the fundamental differences between paroxysmal and persistent AF and the potential impact of those differences on patient management, emphasizing the available therapeutic strategies to achieve rhythm control. Expert commentary: Treatment to prevent AF recurrences is suboptimal, particularly in patients with persistent AF. Emerging technologies, such as documentation of atrial fibrosis using magnetic resonance imaging and documentation of electrical substrate using advanced electrocardiographic imaging techniques are likely to provide valuable insights about patient-specific tailoring of treatments.

  8. Voltage and pace-capture mapping of linear ablation lesions overestimates chronic ablation gap size.

    PubMed

    O'Neill, Louisa; Harrison, James; Chubb, Henry; Whitaker, John; Mukherjee, Rahul K; Bloch, Lars Ølgaard; Andersen, Niels Peter; Dam, Høgni; Jensen, Henrik K; Niederer, Steven; Wright, Matthew; O'Neill, Mark; Williams, Steven E

    2018-04-26

    Conducting gaps in lesion sets are a major reason for failure of ablation procedures. Voltage mapping and pace-capture have been proposed for intra-procedural identification of gaps. We aimed to compare gap size measured acutely and chronically post-ablation to macroscopic gap size in a porcine model. Intercaval linear ablation was performed in eight Göttingen minipigs with a deliberate gap of ∼5 mm left in the ablation line. Gap size was measured by interpolating ablation contact force values between ablation tags and thresholding at a low force cut-off of 5 g. Bipolar voltage mapping and pace-capture mapping along the length of the line were performed immediately, and at 2 months, post-ablation. Animals were euthanized and gap sizes were measured macroscopically. Voltage thresholds to define scar were determined by receiver operating characteristic analysis as <0.56 mV (acutely) and <0.62 mV (chronically). Taking the macroscopic gap size as gold standard, error in gap measurements were determined for voltage, pace-capture, and ablation contact force maps. All modalities overestimated chronic gap size, by 1.4 ± 2.0 mm (ablation contact force map), 5.1 ± 3.4 mm (pace-capture), and 9.5 ± 3.8 mm (voltage mapping). Error on ablation contact force map gap measurements were significantly less than for voltage mapping (P = 0.003, Tukey's multiple comparisons test). Chronically, voltage mapping and pace-capture mapping overestimated macroscopic gap size by 11.9 ± 3.7 and 9.8 ± 3.5 mm, respectively. Bipolar voltage and pace-capture mapping overestimate the size of chronic gap formation in linear ablation lesions. The most accurate estimation of chronic gap size was achieved by analysis of catheter-myocardium contact force during ablation.

  9. Radiofrequency and microwave energy sources in surgical ablation of atrial fibrillation: a comparative analysis.

    PubMed

    Topkara, Veli K; Williams, Mathew R; Barili, Fabio; Bastos, Renata; Liu, Judy F; Liberman, Elyse A; Russo, Mark J; Oz, Mehmet C; Argenziano, Michael

    2006-01-01

    Due to its complexity and risk of bleeding, the Maze III procedure has been largely replaced by surgical ablation for atrial fibrillation (AF) using alternative energy sources. Radiofrequency (RF) and microwave (MW) are the most commonly used energy forms. In this study, we sought to compare these energy modalities in terms of clinical outcomes. Two hundred five patients underwent surgical ablation of AF, from October 1999 to May 2004 at our institution via an endocardial approach. Patients were categorized into 2 groups: RF and MW. Baseline characteristics, operative details, and clinical outcomes were compared between the 2 groups. Rhythm success was defined as freedom from AF and atrial flutter as determined by postoperative electrocardiograms. One hundred twenty patients (58.5%) were ablated using RF, whereas 85 (41.5%) were ablated with MW. Most of the patients had persistent AF in both the RF and MW groups (85.7% versus 80.0%, respectively; P = .363). Intraoperative left atrial size was 6.4 +/- 1.7 cm for the RF group and 6.4 +/- 1.7 cm for the MW group (P = .820). Postoperative rhythm success at 6 and 12 months was 72.4% versus 71.4% (P +/- .611) and 75.0% versus 66.7% (P = .909) for the RF and MW groups, respectively. Hospital length of stay was comparable for both groups (15.4 +/- 14.0 versus 13.3 +/- 13.9 days; P = .307). Postoperative survival at 6 months, 1 year, and 3 years was 90.4%, 89.5%, and 86.1% for RF patients compared to 87.9%, 86.5%, and 84.4% for MW patients, respectively (log rank P = .490). RF and MW energy forms yield comparable postoperative rhythm success, hospital length of stay, and postoperative survival. Both sources are rapid, safe, and effective alternatives to "cut and sew" techniques for surgical treatment of AF.

  10. 3 Tesla MRI-detected brain lesions after pulmonary vein isolation for atrial fibrillation: results of the MACPAF study.

    PubMed

    Haeusler, Karl Georg; Koch, Lydia; Herm, Juliane; Kopp, Ute A; Heuschmann, Peter U; Endres, Matthias; Schultheiss, Heinz-Peter; Schirdewan, Alexander; Fiebach, Jochen B

    2013-01-01

    Left atrial catheter ablation (LACA) is an established therapeutic approach to abolish symptomatic atrial fibrillation (AF). Based on the prospective MACPAF study (clinicaltrials.gov NCT01061931) we report the rate of ischemic brain lesions postablation and their impact on cognitive function. Patients with symptomatic paroxysmal AF were randomized to LACA using the Arctic Front® or the HD Mesh Ablator® catheter. All patients underwent brain MRI at 3 Tesla, neurological, and neuropsychological examinations within 48 hours prior and after the ablation procedure. There was no clinically evident stroke in 37 patients (mean age 62.4 ± 8.4 years; 41% female; median CHADS2 score 1 [IQR 0-2]) after LACA but high-resolution diffusion-weighted imaging (DWI) detected new ischemic lesions in 15 (41%) patients after LACA. Four (27%) of the HD Mesh Ablator® patients and 11 (50%) of the Arctic Front® patients suffered a silent ischemic lesion (P = 0.19). In these 15 patients, there was a nonsignificant trend toward lower cardiac ejection fraction (P = 0.07) and AF episodes during LACA (P = 0.09), while activated clotting time levels, number of energy applications, periprocedural electrocardioversion or CHADS(2) score had no impact. Lesion volumes varied from 5 to 150 mm(3) and 1 to 5 lesions were detected per patient. However, acute brain lesions had no effect on cognitive performance immediately after LACA. Of the DWI lesions postablation 82% were not detectable on FLAIR images 6-9 months postablation. According to 3 Tesla high-resolution DWI, ischemic brain lesions after LACA were common but not associated with impaired cognitive function after the ablation procedure. © 2012 Wiley Periodicals, Inc.

  11. Surgical perspectives in the management of atrial fibrillation

    PubMed Central

    Kyprianou, Katerina; Pericleous, Agamemnon; Stavrou, Antonio; Dimitrakaki, Inetzi A; Challoumas, Dimitrios; Dimitrakakis, Georgios

    2016-01-01

    Atrial fibrillation (AF) is the most common cardiac arrhythmia and a huge public health burden associated with significant morbidity and mortality. For decades an increasing number of patients have undergone surgical treatment of AF, mainly during concomitant cardiac surgery. This has sparked a drive for conducting further studies and researching this field. With the cornerstone Cox-Maze III “cut and sew” procedure being technically challenging, the focus in current literature has turned towards less invasive techniques. The introduction of ablative devices has revolutionised the surgical management of AF, moving away from the traditional surgical lesions. The hybrid procedure, a combination of catheter and surgical ablation is another promising new technique aiming to improve outcomes. Despite the increasing number of studies looking at various aspects of the surgical management of AF, the literature would benefit from more uniformly conducted randomised control trials. PMID:26839656

  12. Determining the Optimal Dose of Adenosine for Unmasking Dormant Pulmonary Vein Conduction Following Atrial Fibrillation Ablation: Electrophysiological and Hemodynamic Assessment. DORMANT-AF Study.

    PubMed

    Prabhu, Sandeep; Mackin, Vincent; McLellan, Alex J A; Phan, Tuong; McGlade, Desmond; Ling, Liang-Han; Peck, Kah Y; Voskoboinik, Alexandr; Pathik, Bupesh; Nalliah, Chrishan J; Wong, Geoff R; Azzopardi, Sonia M; Lee, Geoffrey; Mariani, Justin; Taylor, Andrew J; Kalman, Jonathan M; Kistler, Peter M

    2017-01-01

    ELECTROPHYSIOLOGICAL AND HEMODYNAMIC ASSESSMENT. The significance of adenosine induced dormant pulmonary vein (PV) conduction in atrial fibrillation (AF) ablation remains controversial. The optimal dose of adenosine to determine dormant PV conduction is yet to be systematically explored. ELECTROPHYSIOLOGICAL AND HEMODYNAMIC ASSESSMENT. Consecutive patients undergoing index AF ablation received 3 adenosine doses (12, 18, and 24 mg) in a randomized blinded order, immediately after pulmonary vein isolation (PVI). Electrophysiological (PR prolongation, AV block (AVB) and PV reconnection) and hemodynamic (BP) parameters were measured. A total, 339 doses (113/dose) assessed 191 PVs in 50 patients (66% male, 72% PAF, 52% hypertensive). Dormant PV conduction occurred in 28% of patients (16.5% [32] of PVs). All cases were associated with AVB (AVB: PV reconnection vs. no PV reconnection 100% vs. 83%, P = 0.007). AVB occurred more frequently at 24 mg versus 12 mg (92% vs. 82%, P = 0.019) but not versus 18 mg (91%, P = 0.62). AVB duration progressed between 12 mg (12.0 ± 8.9 seconds), 18 mg (16.1 ± 9.1 seconds, P = 0.001), and 24 mg (19.0 ± 9.3 seconds, P < 0.001) doses. MBP fell further at 24 mg (ΔMBP: 27 ± 12 mmHg) and 18 mg (26 ± 13 mmHg) doses compared to 12 mg (22 ± 10 mmHg vs., P < 0.001). A significant reduction in AVB in patients >110 kg (65% vs. 91% in 70-110 kg group, P < 0.001) in response to adenosine was seen. ELECTROPHYSIOLOGICAL AND HEMODYNAMIC ASSESSMENT. An adenosine dose producing AVB is required to unmask dormant PV conduction. AVB is significantly reduced in patients >110 kg. Weight and dosing variability may in part explain the conflicting results of studies evaluating the clinical utility of adenosine in PVI. © 2016 Wiley Periodicals, Inc.

  13. Renal denervation with standard radiofrequency ablation catheter is effective in 24-hour ambulatory blood pressure reduction - follow-up at 1/3/6/12 months.

    PubMed

    Prochnau, D; Otto, S; Figulla, H-R; Surber, R

    2016-07-01

    To examine the effect of renal denervation (RDN) on 24‑h ambulatory blood pressure (ABP) with a standard radiofrequency ablation catheter (RF catheter). Seventy-five patients with resistant hypertension received bilateral RDN with an RF catheter (6 RF applications, 1 minute each, 8-12 watts). Seventy patients fulfilled inclusion criteria with mean systolic ABP ≥140 mmHg (mean 165/89) despite treatment with ≥3 antihypertensive drugs (mean 5.9) including a diuretic, and were further analysed for ABP changes. Follow-up at 1/3/6/12 months comprised biochemical evaluations and ABP measurement. At 6/12 months, duplex sonography of the renal arteries was additionally performed. At 1/3/6/12 months we observed a significant reduction in systolic ABP of -15/-17/-18/-15 mmHg (n = 55/53/57/50; non-parametric Friedman test, p < 0.001) and diastolic ABP of -6/-9/-10/-7 mmHg (p < 0.001). Of the patients, 70 %/64 % showed a systolic ABP reduction of ≥10 mmHg, and 77 %/70 % of ≥5 mmHg at 6/12-month follow-up. Two patients (2.7 %) developed renal artery stenosis (>70 %) with subsequent stenting without complications. Logistic regression analysis with systolic ABP reduction ≥10 mmHg at 12 months follow-up as criterion revealed that only the mean baseline systolic ABP was significant, OR = 2.174. RDN with a standard RF catheter can be used safely to reduce mean ABP in resistant hypertension as shown in long-term follow-up.

  14. Navigation for fluoroscopy-guided cryo-balloon ablation procedures of atrial fibrillation

    NASA Astrophysics Data System (ADS)

    Bourier, Felix; Brost, Alexander; Kleinoeder, Andreas; Kurzendorfer, Tanja; Koch, Martin; Kiraly, Attila; Schneider, Hans-Juergen; Hornegger, Joachim; Strobel, Norbert; Kurzidim, Klaus

    2012-02-01

    Atrial fibrillation (AFib), the most common arrhythmia, has been identified as a major cause of stroke. The current standard in interventional treatment of AFib is the pulmonary vein isolation (PVI). PVI is guided by fluoroscopy or non-fluoroscopic electro-anatomic mapping systems (EAMS). Either classic point-to-point radio-frequency (RF)- catheter ablation or so-called single-shot-devices like cryo-balloons are used to achieve electrically isolation of the pulmonary veins and the left atrium (LA). Fluoroscopy-based systems render overlay images from pre-operative 3-D data sets which are then merged with fluoroscopic imaging, thereby adding detailed 3-D information to conventional fluoroscopy. EAMS provide tracking and visualization of RF catheters by means of electro-magnetic tracking. Unfortunately, current navigation systems, fluoroscopy-based or EAMS, do not provide tools to localize and visualize single shot devices like cryo-balloon catheters in 3-D. We present a prototype software for fluoroscopy-guided ablation procedures that is capable of superimposing 3-D datasets as well as reconstructing cyro-balloon catheters in 3-D. The 3-D cyro-balloon reconstruction was evaluated on 9 clinical data sets, yielded a reprojected 2-D error of 1.72 mm +/- 1.02 mm.

  15. Isthmus sites identified by Ripple Mapping are usually anatomically stable: A novel method to guide atrial substrate ablation?

    PubMed

    Luther, Vishal; Qureshi, Norman; Lim, Phang Boon; Koa-Wing, Michael; Jamil-Copley, Shahnaz; Ng, Fu Siong; Whinnett, Zachary; Davies, D Wyn; Peters, Nicholas S; Kanagaratnam, Prapa; Linton, Nick

    2018-03-01

    Postablation reentrant ATs depend upon conducting isthmuses bordered by scar. Bipolar voltage maps highlight scar as sites of low voltage, but the voltage amplitude of an electrogram depends upon the myocardial activation sequence. Furthermore, a voltage threshold that defines atrial scar is unknown. We used Ripple Mapping (RM) to test whether these isthmuses were anatomically fixed between different activation vectors and atrial rates. We studied post-AF ablation ATs where >1 rhythm was mapped. Multipolar catheters were used with CARTO Confidense for high-density mapping. RM visualized the pattern of activation, and the voltage threshold below which no activation was seen. Isthmuses were characterized at this threshold between maps for each patient. Ten patients were studied (Map 1 was AT1; Map 2: sinus 1/10, LA paced 2/10, AT2 with reverse CS activation 3/10; AT2 CL difference 50 ± 30 ms). Point density was similar between maps (Map 1: 2,589 ± 1,330; Map 2: 2,214 ± 1,384; P  =  0.31). RM activation threshold was 0.16 ± 0.08 mV. Thirty-one isthmuses were identified in Map 1 (median 3 per map; width 27 ± 15 mm; 7 anterior; 6 roof; 8 mitral; 9 septal; 1 posterior). Importantly, 7 of 31 (23%) isthmuses were unexpectedly identified within regions without prior ablation. AT1 was treated following ablation of 11/31 (35%) isthmuses. Of the remaining 20 isthmuses, 14 of 16 isthmuses (88%) were consistent between the two maps (four were inadequately mapped). Wavefront collision caused variation in low voltage distribution in 2 of 16 (12%). The distribution of isthmuses and nonconducting tissue within the ablated left atrium, as defined by RM, appear concordant between rhythms. This could guide a substrate ablative approach. © 2018 Wiley Periodicals, Inc.

  16. The identification of conduction gaps after pulmonary vein isolation using a new electroanatomic mapping system.

    PubMed

    Masuda, Masaharu; Fujita, Masashi; Iida, Osamu; Okamoto, Shin; Ishihara, Takayuki; Nanto, Kiyonori; Kanda, Takashi; Tsujimura, Takuya; Matsuda, Yasuhiro; Okuno, Shota; Ohashi, Takuya; Tsuji, Aki; Mano, Toshiaki

    2017-11-01

    The reconnection of left atrial-pulmonary vein (LA-PV) conduction after the initial procedure of pulmonary vein (PV) isolation is not rare, and is one of the main cause of atrial fibrillation (AF) recurrence after PV isolation. We investigated feasibility of a new ultrahigh-resolution mapping system using a 64-pole small basket catheter for the identification of LA-PV conduction gaps. This prospective study included 31 consecutive patients (20 with persistent AF) undergoing a second ablation after a PV isolation procedure with LA-PV reconnected conduction at any of the 4 PVs. An LA-PV map was created using the mapping system, and ablation was performed at the estimated gap location. The propagation map identified 54 gaps from 39 ipsilateral PV pairs, requiring manual electrogram reannotation for 23 gaps (43%). Gaps at the anterior and carinal regions of left and right ipsilateral PVs required manual electrogram reannotation more frequently than the other regions. The voltage map could identify the gap only in 19 instances (35%). Electrophysiological properties of the gaps (multiple gaps in the same ipsilateral PVs, conduction time, velocity, width, and length) did not differ between those needing and not needing manual electrogram reannotation. During the gap ablation, either the activation sequence alteration or elimination of PV potentials was observed using a circular catheter placed in the PV, suggesting that all the identified gaps were correct. This new electroanatomic mapping system visualized all the LA-PV gaps in patients undergoing a second AF ablation. Copyright © 2017 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  17. Left atrial concomitant surgical ablation for treatment of atrial fibrillation in cardiac surgery: A meta-analysis of randomized controlled trials

    PubMed Central

    Wang, Chunguo; Ye, Minhua; Lin, Jiang; Jin, Jiang; Hu, Quanteng; Zhu, Chengchu; Chen, Baofu

    2018-01-01

    Introduction Surgical ablation is a generally established treatment for patients with atrial fibrillation undergoing concomitant cardiac surgery. Left atrial (LA) lesion set for ablation is a simplified procedure suggested to reduce the surgery time and morbidity after procedure. The present meta-analysis aims to explore the outcomes of left atrial lesion set versus no ablative treatment in patients with AF undergoing cardiac surgery. Methods A literature research was performed in six database from their inception to July 2017, identifying all relevant randomized controlled trials (RCTs) comparing left atrial lesion set versus no ablative treatment in AF patient undergoing cardiac surgery. Data were extracted and analyzed according to predefined clinical endpoints. Results Eleven relevant RCTs were included for analysis in the present study. The prevalence of sinus rhythm in ablation group was significantly higher at discharge, 6-month and 1-year follow-up period. The morbidity including 30 day mortality, late all-cause mortality, reoperation for bleeding, permanent pacemaker implantation and neurological events were of no significant difference between two groups. Conclusions The result of our meta-analysis demonstrates that left atrial lesion set is an effective and safe surgical ablation strategy for AF patients undergoing concomitant cardiac surgery. PMID:29360851

  18. Pulmonary Vein Antral Isolation and Nonpulmonary Vein Trigger Ablation Are Sufficient to Achieve Favorable Long-Term Outcomes Including Transformation to Paroxysmal Arrhythmias in Patients With Persistent and Long-Standing Persistent Atrial Fibrillation.

    PubMed

    Liang, Jackson J; Elafros, Melissa A; Muser, Daniele; Pathak, Rajeev K; Santangeli, Pasquale; Zado, Erica S; Frankel, David S; Supple, Gregory E; Schaller, Robert D; Deo, Rajat; Garcia, Fermin C; Lin, David; Hutchinson, Mathew D; Riley, Michael P; Callans, David J; Marchlinski, Francis E; Dixit, Sanjay

    2016-11-01

    Transformation from persistent to paroxysmal atrial fibrillation (AF) after ablation suggests modification of the underlying substrate. We examined the nature of initial arrhythmia recurrence in patients with nonparoxysmal AF undergoing antral pulmonary vein isolation and nonpulmonary vein trigger ablation and correlated recurrence type with long-term ablation efficacy after the last procedure. Three hundred and seventeen consecutive patients with persistent (n=200) and long-standing persistent (n=117) AF undergoing first ablation were included. AF recurrence was defined as early (≤6 weeks) or late (>6 weeks after ablation) and paroxysmal (either spontaneous conversion or treated with cardioversion ≤7 days) or persistent (lasting >7 days). During median follow-up of 29.8 (interquartile range: 14.8-49.9) months, 221 patients had ≥1 recurrence. Initial recurrence was paroxysmal in 169 patients (76%) and persistent in 52 patients (24%). Patients experiencing paroxysmal (versus persistent) initial recurrence were more likely to achieve long-term freedom off antiarrhythmic drugs (hazard ratio, 2.2; 95% confidence interval, 1.5-3.2; P<0.0001), freedom on/off antiarrhythmic drugs (hazard ratio, 2.5; 95% confidence interval, 1.6-3.8; P<0.0001), and arrhythmia control (hazard ratio, 5.2; 95% confidence interval, 2.9-9.2; P<0.0001) after last ablation. In patients with persistent and long-standing persistent AF, limited ablation targeting pulmonary veins and documented nonpulmonary vein triggers improves the maintenance of sinus rhythm and reverses disease progression. Transformation to paroxysmal AF after initial ablation may be a step toward long-term freedom from recurrent arrhythmia. © 2016 American Heart Association, Inc.

  19. Pulmonary vein reconnection following catheter ablation of atrial fibrillation using the second-generation cryoballoon versus open-irrigated radiofrequency: results of a multicenter analysis.

    PubMed

    Aryana, Arash; Singh, Sheldon M; Mugnai, Giacomo; de Asmundis, Carlo; Kowalski, Marcin; Pujara, Deep K; Cohen, Andrew I; Singh, Steve K; Fuenzalida, Charles E; Prager, Nelson; Bowers, Mark R; O'Neill, Padraig Gearoid; Brugada, Pedro; d'Avila, André; Chierchia, Gian-Battista

    2016-12-01

    Catheter ablation of atrial fibrillation (CAAF) using the cryoballoon has emerged as an alternate strategy to point-by-point radiofrequency. However, there is little comparative data on long-term durability of pulmonary vein (PV) isolation comparing these two modalities. In this multicenter, retrospective analysis, the incidences/patterns of late PV reconnection following an index CAAF using the second-generation cryoballoon versus open-irrigated, non-force-sensing radiofrequency were examined. Of the 2002 patients who underwent a first-time CAAF, 186/1126 patients (16.5 %) ablated using cryoballoon and 174/876 patients (19.9 %) with non-contact force-guided radiofrequency required a repeat procedure at 11 ± 5 months. During follow-up, the incidence of atrial flutters/tachycardias was lower (19.9 vs. 32.8 %; p = 0.005) and fewer patients exhibited PV reconnection (47.3 vs. 60.9 %; p = 0.007) with cryoballoon versus radiofrequency. Additionally, fewer PVs had reconnected with cryoballoon versus radiofrequency (18.8 vs. 34.6 %; p < 0.001). With cryoballoon, the right inferior (p < 0.001) and left common (p = 0.039) PVs were more likely to exhibit late reconnection, versus the left superior PV with radiofrequency (p = 0.012). However, when comparing the two strategies, the left common PV was more likely to exhibit reconnection with cryoballoon, whereas all other PVs with the exception of the right inferior PV demonstrated a lower reconnection rate with cryoballoon versus radiofrequency. Lastly, in a logistic regression multivariate analysis, cryoballoon ablation and PV ablation time emerged as significant predictors of durable PV isolation at repeat procedure. In this large multicenter, retrospective analysis, CAAF using the second-generation cryoballoon was associated with improved durability of PV isolation compared to open-irrigated, non-force-sensing radiofrequency.

  20. Right diaphragmatic paralysis following endocardial cryothermal ablation of inappropriate sinus tachycardia.

    PubMed

    Vatasescu, Radu; Shalganov, Tchavdar; Kardos, Attila; Jalabadze, Khatuna; Paprika, Dora; Gyorgy, Margit; Szili-Torok, Tamas

    2006-10-01

    Inappropriate sinus tachycardia (IST) is a rare disorder amenable to catheter ablation when refractory to medical therapy. Radiofrequency (RF) catheter modification/ablation of the sinus node (SN) is the usual approach, although it can be complicated by right phrenic nerve paralysis. We describe a patient with IST, who had symptomatic recurrences despite previous acutely successful RF SN modifications, including the use of electroanatomical mapping/navigation system. We decided to try transvenous cryothermal modification of the SN. We used 2 min applications at -85 degrees C at sites of the earliest atrial activation guided by activation mapping during isoprenaline infusion. Every application was preceded by high output stimulation to reveal phrenic nerve proximity. During the last application, heart rate slowly and persistently fell below 85 bpm despite isoprenaline infusion, but right diaphragmatic paralysis developed. At 6 months follow-up, the patient was asymptomatic and the diaphragmatic paralysis had partially resolved. This is the first report, we believe, of successful SN modification for IST by endocardial cryoablation, although this case also demonstrates the considerable risk of right phrenic nerve paralysis even with this ablation energy.

  1. Initial clinical results with the ThermoCool® SmartTouch® Surround Flow catheter.

    PubMed

    Gonna, Hanney; Domenichini, Giulia; Zuberi, Zia; Norman, Mark; Kaba, Riyaz; Grimster, Alexander; Gallagher, Mark M

    2017-08-01

    The Biosense Webster ThermoCool® SmartTouch® Surround Flow (STSF) catheter is a recently developed ablation catheter incorporating Surround Flow (SF) technology to ensure efficient cooling and force sensing to quantify tissue contact. In our unit, it superseded the ThermoCool® SF catheter from the time of its introduction in May 2015. Procedure-related data were collected prospectively for the first 100 ablation procedures performed in our department using the STSF catheter. From a database of 654 procedures performed in our unit using the SF catheter, we selected one to match each STSF procedure, matching for procedure type, operator experience, patient age, and gender. The groups were well matched for patient age, gender, and procedure type. Procedure duration was similar in both groups (mean 225.5 vs. 221.4 min, IQR 106.5 vs. 91.5, P = 0.55), but fluoroscopy duration was shorter in the STSF group (mean 25.8 vs. 30.0, IQR 19.6 vs. 18.5, P = 0.03). No complication occurred in the STSF group. Complications occurred in two cases in the SF group (one pericardial effusion requiring drainage and one need for permanent pacing). Complete procedural success was achieved in 98 cases in the STSF group and 94 cases in the SF group (P = 0.15). The composite endpoint of procedure failure or acute complication was less common in the STSF group (2 vs. 8, P = 0.05). The STSF catheter is safe and effective in treating a range of arrhythmias. Compared with the SF catheter, it shows a trend towards improved safety-efficacy balance. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2016. For permissions please email: journals.permissions@oup.com.

  2. Long-term outcomes of remote magnetic navigation for ablation of supraventricular tachycardias.

    PubMed

    Kim, Sung-Hwan; Oh, Yong-Seog; Kim, Dong-Hwi; Choi, Ik Jun; Kim, Tae-Seok; Shin, Woo-Seung; Kim, Ji-Hoon; Jang, Sung-Won; Lee, Man Young; Rho, Tai-Ho

    2015-08-01

    Little is known about the long-term outcomes of catheter ablation of supraventricular tachycardia (SVT) using remote magnetic navigation system (RMN). One hundred twenty patients underwent catheter ablation of SVTs with RMN (Niobe, Stereotaxis, USA): atrioventricular nodal re-entrant tachycardia (AVNRT; n = 59), atrioventricular re-entrant tachycardia (AVRT; n = 45), and focal atrial tachycardia (AT, n = 16). The outcome of AVRT with right free wall accessory pathway was compared with those of a group of 26 consecutive patients undergoing manual ablation. Mean follow-up period was 2.2 ± 1.4 years. Overall arrhythmia-free survival was 86%; AVRT (77%), AVNRT (96%), and focal AT (71%). After the learning period (initial 50 cases), procedural outcomes had improved for AVRT and AVNRT (91% in overall group, 90% in AVRT group, 100% in AVNRT group, and 68% in focal AT group). The recurrence-free rate was higher for the free wall accessory pathways than those of the other sites (92 vs. 73%, log-rank P = 0.06). Furthermore, when it is confined for the right free wall accessory pathway, RMN showed excellent long-term outcome (7/7, 100 %) compared to the results of manual approach (18/26, 69.2%, log-rank P = 0.07). RMN showed favorable long-term outcomes for the ablation of SVT. In our experience, RMN-guided ablation may be associated with a higher success rate as compared to manual ablation when treating right-sided free wall pathways.

  3. Utility of esophageal temperature monitoring during pulmonary vein isolation for atrial fibrillation using duty-cycled phased radiofrequency ablation.

    PubMed

    Deneke, Thomas; Bünz, Kathrin; Bastian, Annely; Päsler, Marcus; Anders, Helge; Lehmann, Rainer; Meuser, Wolfgang; de Groot, Joris R; Horlitz, Marc; Haberkorn, Ron; Mügge, Andreas; Shin, Dong-In

    2011-03-01

    A novel ablation system has been introduced for rapid treatment of atrial fibrillation (AF). This system delivers duty-cycled phased radiofrequency (RF) energy via an over-the-wire catheter (PVAC® , Medtronic) to achieve pulmonary vein (PV) isolation. Lower power and depth control suggests that collateral damage might be minimized. However, no studies have investigated the potential for thermal effect and damage to the esophagus. Ninety consecutive patients undergoing PV-isolation were evaluated. Group A (48 patients) had continuous luminal esophageal temperature (LET) monitoring using a temperature probe with 3 metal electrodes located in the vicinity of the targeted PV ostia. Ablation ceased when LET exceeded 40 °C. Only patients with LET ≥ 39 °C underwent endoscopic evaluation to assess esophageal damage. Group B (42 patients) excluded LET monitoring but all patients underwent endoscopy. In Group A, 27 (56%) patients showed LET ≥ 39 °C (mean LET 40.5 °C). Endoscopy revealed esophageal alterations in 5 (8%) (3 erythema and 2 intramural bleeding). One hundred eighty-nine out of 190 (99.5%) targeted PVs were successfully isolated, with 1 PV unsuccessful due to high LET. In Group B all 165 targeted PVs (100%) were successfully isolated. Endoscopy in Group 2 revealed no esophageal alterations. Using a duty-cycled, phased RF ablation system is safe and effective to isolate PVs. No Eso alteration was documented after ablation when LET was not monitored. This suggests that the LET probe may contribute to the thermal effect. Whether the documented increments in LET are due to direct tissue heating or possible interaction between the LET probe requires further investigation. © 2010 Wiley Periodicals, Inc.

  4. Interest of waiting time for spontaneous early reconnection after cavotricuspid isthmus ablation: A monocentric randomized trial.

    PubMed

    Marchandise, Sébastien; Scavée, Christophe; Barbraud, Cynthia; de Meester de Ravenstein, Christophe; Balola Bagalwa, Mittérand; Goesaert, Cédric; Reis-Pinheiro, Ivone; le Polain de Waroux, Jean-Benoit

    2017-12-01

    The aim of this study was to determine the rate of recurrent atrial flutter (AFl) after isolated cavotricuspid isthmus (CTI) ablation and to evaluate the impact of a waiting period with the search for early resumption of the CTI block on the long-term outcome. Three hundred and nineteen consecutive patients referred for typical AFl ablation were randomly assigned to CTI ablation with continuous reevaluation of the CTI block during 30 minutes and early reablation if needed (waiting time [WT] + group, n  =  155) or to CTI ablation with no waiting period after proven bidirectional CTI block (WT - group, n  =  164). All patients were regularly followed-up. In the WT+ group, 10 patients (6%) presented a recovery across the CTI (time to recovery: 17 ± 7') and were reablated at the end of the waiting period. After a median follow-up of 21 months, the rate of recurrent AFl was significantly higher in the WT - group as compared to the WT+ group (11.6% [19/164] vs 2.5% [4/155], respectively; P  =  0.007). However, no significant differences in the subsequent rate of AF were observed between the two groups (29% [WT -] vs 32% [WT+], P  =  0.66). During the follow-up, 28 patients from the WT - group underwent a second ablation procedure (16 AFl redo and 12 AF ablation) versus 10 patients form the WT+ group (three AFl redo and seven AF ablation). Waiting 30 minutes after CTI ablation to check for early resumption and early reablation allows for decreasing significantly the rate of recurrent atrial flutter. © 2017 Wiley Periodicals, Inc.

  5. Successful retrieval of an entrapped Rotablator burr using 5 Fr guiding catheter.

    PubMed

    Kimura, Masayoshi; Shiraishi, Jun; Kohno, Yoshio

    2011-10-01

    Although burr entrapment is a rare complication of the Rotablator, it is extremely difficult to retrieve a fixedly entrapped burr without surgical procedure. An 84-year-old male with effort angina had heavily calcified coronary trees as well as severe stenosis in the mid LCx, and moderate stenosis in the proximal LCx, and in the LMT. We planned to perform rotational atherectomy in the LCx lesions. Using 7 Fr Q-curve guiding catheter and Rotawire floppy, we began to ablate using 1.5-mm burr at 200,000 rpm. Because the burr could not pass the proximal stenosis, we exchanged the wire for Rotawire extrasupport and the burr for 1.25-mm burr, and restarted the ablation at 220,000 rpm. Although the burr could manage to pass the proximal stenosis, it had become trapped in the mid LCx lesion. Simple pull on the Rotablator, rotation of the burr, and crossing the Conquest (Confianza) wire could not retrieve it. Thus, we cut off the drive shaft and sheath of the Rotablator, inserted 5 Fr 120-cm straight guiding catheter (Heartrail ST01; Terumo) through the remaining Rotablator system, pushed the catheter tip to the lesion around the burr as well as simultaneously pulled the Rotablator, and finally could retrieve it. Then we implanted stents in the LCx and in the LMT without difficulty. The 5 Fr straight guiding catheter might be useful for retrieving an entrapped burr (1.25-mm burr). Copyright © 2011 Wiley-Liss, Inc.

  6. A systematical analysis of in vivo contact forces on virtual catheter tip/tissue surface contact during cardiac mapping and intervention.

    PubMed

    Okumura, Yasuo; Johnson, Susan B; Bunch, T Jared; Henz, Benhur D; O'Brien, Christine J; Packer, Douglas L

    2008-06-01

    While catheter tip/tissue contact has been shown to be an important determinant of ablative lesions in in vitro studies, the impact of contact on the outcomes of mapping and ablation in the intact heart has not been evaluated. Twelve dogs underwent atrial ablation guided by the Senesitrade mark robotic catheter remote control system. After intracardiac ultrasound (ICE) validation of contact force measured by an in-line mechanical sensor, the relationship between contact force and individual lesion formation was established during irrigated-tipped ablation (flow 17 mL/sec) at 15 watts for 30 seconds. Minimal contact by ICE correlated with force of 4.7 +/- 5.8 grams, consistent contact 9.9 +/- 8.6 grams and tissue tenting produced 25.0 +/- 14.0 grams. Conversely, catheter tip/tissue contact by ICE was predicted by contact force. A contact force of 10-20 and > or =20 grams generated full-thickness, larger volume ablative lesions than that created with <10 grams (98 +/- 69 and 89 +/- 70 mm(3) vs 40 +/- 42 mm(3), P < 0.05). Moderate (10 grams) and marked contact (15-20 grams) application produced 1.5 X greater electroanatomic map volumes that were seen with minimal contact (5 grams) (26 +/- 3 cm(3) vs 33 +/- 6, 39 +/- 3 cm(3), P < 0.05). The electroanatomic map/CT merge process was also more distorted when mapping was generated at moderate to marked contact force. This study shows that mapping and ablation using a robotic sheath guidance system are critically dependent on generated force. These findings suggest that ablative lesion size is optimized by the application of 10-20 grams of contact force, although mapping requires lower-force application to avoid image distortions.

  7. Catheter-Based Renal Sympathetic Denervation Significantly Inhibits Atrial Fibrillation Induced by Electrical Stimulation of the Left Stellate Ganglion and Rapid Atrial Pacing

    PubMed Central

    Po, Sunny S.; Wang, Huan; Zhang, Ling; Zhang, Feng; Wang, Kun; Zhou, Qina

    2013-01-01

    Background Sympathetic activity involves the pathogenesis of atrial fibrillation (AF). Renal sympathetic denervation (RSD) decreases sympathetic renal afferent nerve activity, leading to decreased central sympathetic drive. The aim of this study was to identify the effects of RSD on AF inducibility induced by hyper-sympathetic activity in a canine model. Methods To establish a hyper-sympathetic tone canine model of AF, sixteen dogs were subjected to stimulation of left stellate ganglion (LSG) and rapid atrial pacing (RAP) for 3 hours. Then animals in the RSD group (n = 8) underwent radiofrequency ablation of the renal sympathetic nerve. The control group (n = 8) underwent the same procedure except for ablation. AF inducibility, effective refractory period (ERP), ERP dispersion, heart rate variability and plasma norepinephrine levels were measured at baseline, after stimulation and after ablation. Results LSG stimulation combined RAP significantly induced higher AF induction rate, shorter ERP, larger ERP dispersion at all sites examined and higher plasma norepinephrine levels (P<0.05 in all values), compared to baseline. The increased AF induction rate, shortened ERP, increased ERP dispersion and elevated plasma norepinephrine levels can be almost reversed by RSD, compared to the control group (P<0.05). LSG stimulation combined RAP markedly shortened RR-interval and standard deviation of all RR-intervals (SDNN), Low-frequency (LF), high-frequency (HF) and LF/HF ratio (P<0.05). These changes can be reversed by RSD, compared to the control group (P<0.05). Conclusions RSD significantly reduced AF inducibility and reversed the atrial electrophysiological changes induced by hyper-sympathetic activity. PMID:24223140

  8. The definition of success in atrial fibrillation ablation surgery.

    PubMed

    Hunter, Steven

    2014-01-01

    In spite of recent attempts to define and clarify the treatment endpoints in atrial fibrillation (AF) ablation surgery, the definition of success has remained blurred. It is of importance to address the burden of AF in the non-symptomatic population. Thromboembolic events invariably blight the outcomes, therefore freedom from stroke must be incorporated into any definition of success and guidelines. It is essential to meticulously study the long-term outcomes of an unsuccessful treatment as a supplement to the definition of success.

  9. Intracardiac echo-facilitated 3D electroanatomical mapping of ventricular arrhythmias from the papillary muscles: assessing the 'fourth dimension' during ablation.

    PubMed

    Proietti, Riccardo; Rivera, Santiago; Dussault, Charles; Essebag, Vidal; Bernier, Martin L; Ayala-Paredes, Felix; Badra-Verdu, Mariano; Roux, Jean-François

    2017-01-01

    Ventricular arrhythmias (VA) originating from a papillary muscle (PM) have recently been described as a distinct clinical entity with peculiar features that make its treatment with catheter ablation challenging. Here, we report our experience using an intracardiac echo-facilitated 3D electroanatomical mapping approach in a case series of patients undergoing ablation for PM VA. Sixteen patients who underwent catheter ablation for ventricular tachycardia (VT) or symptomatic premature ventricular contractions originating from left ventricular PMs were included in the study. A total of 24 procedures (mean 1.5 per patient) were performed: 15 using a retrograde aortic approach and 9 using a transseptal approach. Integrated intracardiac ultrasound for 3D electroanatomical mapping was used in 15 of the 24 procedures. The posteromedial PM was the most frequent culprit for the clinical arrhythmia, and the body was the part of the PM most likely to be the successful site for ablation. The site of ablation was identified based on the best pace map matching the clinical arrhythmia and the site of earliest the activation. At a mean follow-up of 10.5 ± 7 months, only two patients had recurrent arrhythmias following a repeat ablation procedure. An echo-facilitated 3D electroanatomical mapping allows for real-time creation of precise geometries of cardiac chambers and endocavitary structures. This is useful during procedures such as catheter ablation of VAs originating from PMs, which require detailed representation of anatomical landmarks. Routine adoption of this technique should be considered to improve outcomes of PM VA ablation. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2016. For permissions please email: journals.permissions@oup.com.

  10. Remote magnetic navigation to map and ablate left coronary cusp ventricular tachycardia.

    PubMed

    Burkhardt, J David; Saliba, Walid I; Schweikert, Robert A; Cummings, Jennifer; Natale, Andrea

    2006-10-01

    Premature ventricular contractions (PVCs) and ventricular tachycardia may arise from the coronary cusps. Navigation, mapping, and ablation in the coronary cusps can be challenging. Remote magnetic navigation may offer an alternative to conventional manually operated catheters. We report a case of left coronary cusp ventricular tachycardia ablation using remote magnetic navigation. Right ventricular outflow tract and coronary cusp mapping, and ablation of the left coronary cusp using a remote magnetic navigation and three-dimensional (3-D) mapping system was performed in a 28-year-old male with frequent, symptomatic PVCs and ventricular tachycardia. Successful ablation of left coronary cusp ventricular tachycardia was performed using remote magnetic navigation. Remote magnetic navigation may be used to map and ablate PVCs and ventricular tachycardia originating from the coronary cusps.

  11. Pulmonary Vein Isolation with the Cryoballoon Technique: Feasibility, Procedural Outcomes, and Adoption in the Real World: Data from One Shot Technologies TO Pulmonary Vein Isolation (1STOP) Project.

    PubMed

    Padeletti, Luigi; Curnis, Antonio; Tondo, Claudio; Lunati, Maurizio; Porcellini, Stefano; Verlato, Roberto; Sciarra, Luigi; Senatore, Gaetano; Catanzariti, Domenico; Leoni, Loira; Landolina, Maurizio; Delise, Pietro; Iacopino, Saverio; Pieragnoli, Paolo; Arena, Giuseppe

    2017-01-01

    Catheter ablation (CA) is recommended for patients with drug refractory symptomatic atrial fibrillation (AF). "One Shot" catheters have been introduced to simplify CA and cryoballoon ablation (CBA) is spreading rapidly. Few real-world data are available on standard clinical practice, mainly from single-center experience. We aimed to evaluate clinical settings, demographics, and acute procedural outcomes in a large cohort of patients treated with CBA. A total of 903 patients (73% male, mean age 59 ± 11) underwent pulmonary vein CBA. Correlations between the patient's inclusion time and clinical characteristics, procedure duration, acute success rate, and intraprocedural complications were evaluated. Seventy-seven percent of patients were affected by paroxysmal AF and 23% by persistent AF. Overall, acute success rate was 97.9% and periprocedural complications were observed in 35 (3.9%) patients, 13 (1.4%) of which were classified as major complications. With respect to the patient's inclusion time analysis, an increase in treatment of persistent AF was observed, a significant decrease in CBA times (procedure, ablation, and fluoroscopy: 136.0 ± 46.5 minutes, 28.8 ± 19.6 minutes, and 34.3 ± 15.4 minutes, respectively) was observed, with comparable acute success rate and intraprocedural complications over time. The rate of major complications was extremely low (1.4%); no death, atrioesophageal fistula, stroke, or other major periinterventional or late complications occurred. This series represents the largest experience of CBA in the treatment of AF that also describes the adoption curve of this relatively recent technology. CBA showed an excellent safety profile when performed in a large real-world clinical setting, with satisfactory acute success rate and, on average, short procedural times. clinicaltrials.gov (NCT01007474). © 2016 Wiley Periodicals, Inc.

  12. Magnetic versus manual catheter navigation for ablation of free wall accessory pathways in children.

    PubMed

    Kim, Jeffrey J; Macicek, Scott L; Decker, Jamie A; Kertesz, Naomi J; Friedman, Richard A; Cannon, Bryan C

    2012-08-01

    Transcatheter ablation of accessory pathway (AP)-mediated tachycardia is routinely performed in children. Little data exist regarding the use of magnetic navigation (MN) and its potential benefits for ablation of AP-mediated tachycardia in this population. We performed a retrospective review of prospectively gathered data in children undergoing radiofrequency ablation at our institution since the installation of MN (Stereotaxis Inc, St. Louis, MO) in March 2009. The efficacy and safety between an MN-guided approach and standard manual techniques for mapping and ablation of AP-mediated tachycardia were compared. During the 26-month study period, 145 patients underwent radiofrequency ablation for AP-mediated tachycardia. Seventy-three patients were ablated with MN and 72 with a standard manual approach. There were no significant differences in demographic factors between the 2 groups with a mean cohort age of 13.1±4.0 years. Acute success rates were equivalent with 68 of 73 (93.2%) patients in the MN group being successfully ablated versus 68 of 72 (94.4%) patients in the manual group (P=0.889). During a median follow-up of 21.4 months, there were no recurrences in the MN group and 2 recurrences in the manual group (P=0.388). There were no differences in time to effect, number of lesions delivered, or average ablation power. There was also no difference in total procedure time, but fluoroscopy time was significantly reduced in the MN group at 14.0 (interquartile range, 3.8-23.9) minutes compared with the manual group at 28.1 (interquartile range, 15.3-47.3) minutes (P<0.001). There were no complications in either group. MN is a safe and effective approach to ablate AP-mediated tachycardia in children.

  13. Ultrafast laser ablation for targeted atherosclerotic plaque removal

    NASA Astrophysics Data System (ADS)

    Lanvin, Thomas; Conkey, Donald B.; Descloux, Laurent; Frobert, Aurelien; Valentin, Jeremy; Goy, Jean-Jacques; Cook, Stéphane; Giraud, Marie-Noelle; Psaltis, Demetri

    2015-07-01

    Coronary artery disease, the main cause of heart disease, develops as immune cells and lipids accumulate into plaques within the coronary arterial wall. As a plaque grows, the tissue layer (fibrous cap) separating it from the blood flow becomes thinner and increasingly susceptible to rupturing and causing a potentially lethal thrombosis. The stabilization and/or treatment of atherosclerotic plaque is required to prevent rupturing and remains an unsolved medical problem. Here we show for the first time targeted, subsurface ablation of atherosclerotic plaque using ultrafast laser pulses. Excised atherosclerotic mouse aortas were ablated with ultrafast near-infrared (NIR) laser pulses. The physical damage was characterized with histological sections of the ablated atherosclerotic arteries from six different mice. The ultrafast ablation system was integrated with optical coherence tomography (OCT) imaging for plaque-specific targeting and monitoring of the resulting ablation volume. We find that ultrafast ablation of plaque just below the surface is possible without causing damage to the fibrous cap, which indicates the potential use of ultrafast ablation for subsurface atherosclerotic plaque removal. We further demonstrate ex vivo subsurface ablation of a plaque volume through a catheter device with the high-energy ultrafast pulse delivered via hollow-core photonic crystal fiber.

  14. Catheter-based renal denervation for resistant hypertension: 12-month results of the EnligHTN I first-in-human study using a multielectrode ablation system.

    PubMed

    Papademetriou, Vasilios; Tsioufis, Costas P; Sinhal, Ajay; Chew, Derek P; Meredith, Ian T; Malaiapan, Yuvi; Worthley, Matthew I; Worthley, Stephen G

    2014-09-01

    Renal denervation has emerged as a novel approach for the treatment of patients with drug-resistant hypertension. To date, only limited data have been published using multielectrode radiofrequency ablation systems. In this article, we present the 12-month data of EnligHTN I, a first-in-human study using a multielectrode ablation catheter. EnligHTN I enrolled 46 patients (average age, 60±10 years; on average 4.7±1.0 medications) with drug-resistant hypertension. Eligible patients were on ≥3 antihypertensive medications and had a systolic blood pressure (BP) ≥160 mm Hg (≥150 mm Hg for diabetics). Bilateral renal artery ablation was performed using a percutaneous femoral approach and standardized techniques. The average baseline office BP was 176/96 mm Hg, average 24-hour ambulatory BP was 150/83 mm Hg, and average home BP was 158/90 mm Hg. The average reductions (mm Hg) at 1, 3, 6, and 12 months were as follows: office: -28/-10, -27/-10, -26/-10, and -27/-11 mm Hg (P<0.001 for all); 24-hour ambulatory: -10/-5, -10/-5, -10/-6 (P<0.001 for all), and -7/-4 for 12 months (P<0.0094). Reductions in home measurements (based on 2-week average) were -9/-4, -8/-5,-10/-7, and -11/-6 mm Hg (P<0.001 at 12 months). At 12 months, there were no signals of worsening renal function and no new serious or life-threatening adverse events. One patient with baseline nonocclusive renal artery stenosis progressed to 75% diameter stenosis, requiring renal artery stenting. The 12-month data continue to demonstrate safety and efficacy of the EnligHTN ablation system in patients with drug-resistant hypertension. Home BP measurements parallel measurements obtained with 24-hour ambulatory monitoring. © 2014 American Heart Association, Inc.

  15. Minimally invasive surgery for atrial fibrillation

    PubMed Central

    Suwalski, Piotr

    2013-01-01

    Atrial fibrillation (AF) remains the most common cardiac arrhythmia, affecting nearly 2% of the general population worldwide. Minimally invasive surgical ablation remains one of the most dynamically evolving fields of modern cardiac surgery. While there are more than a dozen issues driving this development, two seem to play the most important role: first, there is lack of evidence supporting percutaneous catheter based approach to treat patients with persistent and long-standing persistent AF. Paucity of this data offers surgical community unparalleled opportunity to challenge guidelines and change indications for surgical intervention. Large, multicenter prospective clinical studies are therefore of utmost importance, as well as honest, clear data reporting. Second, a collaborative methodology started a long-awaited debate on a Heart Team approach to AF, similar to the debate on coronary artery disease and transcatheter valves. Appropriate patient selection and tailored treatment options will most certainly result in better outcomes and patient satisfaction, coupled with appropriate use of always-limited institutional resources. The aim of this review, unlike other reviews of minimally invasive surgical ablation, is to present medical professionals with two distinctly different, approaches. The first one is purely surgical, Standalone surgical isolation of the pulmonary veins using bipolar energy source with concomitant amputation of the left atrial appendage—a method of choice in one of the most important clinical trials on AF—The Atrial Fibrillation Catheter Ablation Versus Surgical Ablation Treatment (FAST) Trial. The second one represents the most complex approach to this problem: a multidisciplinary, combined effort of a cardiac surgeon and electrophysiologist. The Convergent Procedure, which includes both endocardial and epicardial unipolar ablation bonds together minimally invasive endoscopic surgery with electroanatomical mapping, to deliver best of

  16. Accuracy of epicardial electroanatomic mapping and ablation of sustained ventricular tachycardia merged with heart CT scan in chronic Chagasic cardiomyopathy.

    PubMed

    Valdigem, Bruno Pereira; da Silva, Nilton José Carneiro; Dietrich, Cristiano Oliveira; Moreira, Dalmo; Sasdelli, Roberto; Pinto, Ibraim M; Cirenza, Claudio; de Paola, Angelo Amato Vincenzo

    2010-11-01

    As damage to coronary arteries is a potential complication of epicardial RF catheter ablation (EPRFCA), the procedure must be associated with coronary angiography. Chronic Chagasic cardiomiopathy (CCC) is a disease where epicardial VT are common. Eletroanatomic mapping merged with computed totmography (CT) scan data is a useful tool for mapping the endocardium, and its accuracy in guiding ablation on the epicardium was not adequately evaluated so far. Compare electronatomic map merged with Heart CT to fluoroscopy for epicardial ablation of CCC. Describe the distribution of the scars on CCC. We performed epicardial and endocardial mapping and ablation using CARTO XP V8 on eight patients and merged the map with coronary arteries CT scan using at least three landmarks. To compare the 3D image obtained with CARTO MERGE and the 2D fluoroscopic image obtained during the ablation procedure, we used computer graphic software (Inkscape™) in order to prove that the images were equivalent and to compare the distance between the catheter tip on fluoroscopy to catheter tip on 3D EA map. EPRFCA was successfully performed in all patients and they did not present recurrence for at least 3-month follow-up. The mean difference between the tip of the catheter on fluoroscopy and on the 3D model was 6.03 ± 2.09 mm. Scars were present in the epicardium and endocardium and most of patients presented with posterior wall scars and RV scar. The combination of electroanatomic map and CT coronary artery scan data is feasible and can be an important tool for EPRFCA in patients with CCC and VT.

  17. Impact of number of co-existing rotors and inter-electrode distance on accuracy of rotor localization☆,☆☆

    PubMed Central

    Aronis, Konstantinos N.; Ashikaga, Hiroshi

    2018-01-01

    Background Conflicting evidence exists on the efficacy of focal impulse and rotor modulation on atrial fibrillation ablation. A potential explanation is inaccurate rotor localization from multiple rotors coexistence and a relatively large (9–11 mm) inter-electrode distance (IED) of the multi-electrode basket catheter. Methods and results We studied a numerical model of cardiac action potential to reproduce one through seven rotors in a two-dimensional lattice. We estimated rotor location using phase singularity, Shannon entropy and dominant frequency. We then spatially downsampled the time series to create IEDs of 2–30 mm. The error of rotor localization was measured with reference to the dynamics of phase singularity at the original spatial resolution (IED = 1 mm). IED has a significant impact on the error using all the methods. When only one rotor is present, the error increases exponentially as a function of IED. At the clinical IED of 10 mm, the error is 3.8 mm (phase singularity), 3.7 mm (dominant frequency), and 11.8 mm (Shannon entropy). When there are more than one rotors, the error of rotor localization increases 10-fold. The error based on the phase singularity method at the clinical IED of 10 mm ranges from 30.0 mm (two rotors) to 96.1 mm (five rotors). Conclusions The magnitude of error of rotor localization using a clinically available basket catheter, in the presence of multiple rotors might be high enough to impact the accuracy of targeting during AF ablation. Improvement of catheter design and development of high-density mapping catheters may improve clinical outcomes of FIRM-guided AF ablation. PMID:28988690

  18. Impact of number of co-existing rotors and inter-electrode distance on accuracy of rotor localization.

    PubMed

    Aronis, Konstantinos N; Ashikaga, Hiroshi

    Conflicting evidence exists on the efficacy of focal impulse and rotor modulation on atrial fibrillation ablation. A potential explanation is inaccurate rotor localization from multiple rotors coexistence and a relatively large (9-11mm) inter-electrode distance (IED) of the multi-electrode basket catheter. We studied a numerical model of cardiac action potential to reproduce one through seven rotors in a two-dimensional lattice. We estimated rotor location using phase singularity, Shannon entropy and dominant frequency. We then spatially downsampled the time series to create IEDs of 2-30mm. The error of rotor localization was measured with reference to the dynamics of phase singularity at the original spatial resolution (IED=1mm). IED has a significant impact on the error using all the methods. When only one rotor is present, the error increases exponentially as a function of IED. At the clinical IED of 10mm, the error is 3.8mm (phase singularity), 3.7mm (dominant frequency), and 11.8mm (Shannon entropy). When there are more than one rotors, the error of rotor localization increases 10-fold. The error based on the phase singularity method at the clinical IED of 10mm ranges from 30.0mm (two rotors) to 96.1mm (five rotors). The magnitude of error of rotor localization using a clinically available basket catheter, in the presence of multiple rotors might be high enough to impact the accuracy of targeting during AF ablation. Improvement of catheter design and development of high-density mapping catheters may improve clinical outcomes of FIRM-guided AF ablation. Copyright © 2017 Elsevier Inc. All rights reserved.

  19. Stand-Alone Pulmonary Vein Isolation Versus Pulmonary Vein Isolation With Additional Substrate Modification as Index Ablation Procedures in Patients With Persistent and Long-Standing Persistent Atrial Fibrillation: The Randomized Alster-Lost-AF Trial (Ablation at St. Georg Hospital for Long-Standing Persistent Atrial Fibrillation).

    PubMed

    Fink, Thomas; Schlüter, Michael; Heeger, Christian-Hendrik; Lemes, Christine; Maurer, Tilman; Reissmann, Bruno; Riedl, Johannes; Rottner, Laura; Santoro, Francesco; Schmidt, Boris; Wohlmuth, Peter; Mathew, Shibu; Sohns, Christian; Ouyang, Feifan; Metzner, Andreas; Kuck, Karl-Heinz

    2017-07-01

    Pulmonary vein isolation (PVI) for persistent atrial fibrillation is associated with limited success rates and often requires multiple procedures to maintain stable sinus rhythm. In the prospective and randomized Alster-Lost-AF trial (Ablation at St. Georg Hospital for Long-Standing Persistent Atrial Fibrillation), we sought to assess, in patients with symptomatic persistent or long-standing persistent atrial fibrillation, the outcomes of initial ablative strategies comprising either stand-alone PVI (PVI-only approach) or a stepwise approach of PVI followed by complex fractionated atrial electrogram ablation and linear ablation (Substrate-modification approach). Patients were randomized 1:1 to stand-alone PVI or PVI plus substrate modification. The primary study end point was freedom from recurrence of any atrial tachyarrhythmia, outside a 90-day blanking period, at 12 months. A total of 124 patients were enrolled, with 118 patients included in the analysis (61 in the PVI-only group, 57 in the Substrate-modification group). Atrial tachyarrhythmias recurred in 28 PVI-only group patients and 24 Substrate-modification group patients, for 1-year freedom from tachyarrhythmia recurrence after a single ablation procedure of 54% (95% confidence interval, 43%-68%) in the PVI-only and 57% (95% confidence interval, 46%-72%) in the Substrate-modification group ( P =0.86). Twenty-four patients in the PVI-only group (39%) and 18 in the Substrate-modification group (32%) were without arrhythmia recurrence and off antiarrhythmic drug therapy at the end of the 12-month follow-up. In patients with persistent and long-standing persistent atrial fibrillation, no significant difference was observed in 12-month freedom from atrial tachyarrhythmias between an index ablative approach of stand-alone PVI and a stepwise approach of PVI plus complex fractionated atrial electrogram and linear ablation. URL: http://www.clinicaltrials.gov. Unique identifier: NCT00820625. © 2017 American Heart

  20. Accessory pathway ablation in a 6-year-old girl using remote magnetic navigation as an alternative to cryoablation.

    PubMed

    Mantziari, Lilian; Rigby, Michael; Till, Janice; Ernst, Sabine

    2013-03-01

    A 6-year-old girl with evidence of a parahisian accessory pathway on a baseline electrocardiogram underwent successful catheter ablation using magnetic navigation. Magnetic remote controlled ablation eliminated the parahisian pathway with the first radiofrequency application. A second anterolaterally located concealed pathway was successfully ablated in the same session, resulting in exclusively atrioventricular nodal conduction bidirectionally (total fluoroscopy, 4 min; 25 μGy).

  1. Magnetic electroanatomical mapping for ablation of focal atrial tachycardias.

    PubMed

    Marchlinski, F; Callans, D; Gottlieb, C; Rodriguez, E; Coyne, R; Kleinman, D

    1998-08-01

    Uniform success for ablation of focal atrial tachycardias has been difficult to achieve using standard catheter mapping and ablation techniques. In addition, our understanding of the complex relationship between atrial anatomy, electrophysiology, and surface ECG P wave morphology remains primitive. The magnetic electroanatomical mapping and display system (CARTO) offers an on-line display of electrical activation and/or signal amplitude related to the anatomical location of the recorded sites in the mapped chamber. A window of electrical interest is established based on signals timed from an electrical reference that usually represents a fixed electrogram recording from the coronary sinus or the atrial appendage. This window of electrical interest is established to include atrial activation prior to the onset of the P wave activity associated with the site of origin of a focal atrial tachycardia. Anatomical and electrical landmarks are defined with limited fluoroscopic imaging support and more detailed global chamber and more focal atrial mapping can be performed with minimal fluoroscopic guidance. A three-dimensional color map representing atrial activation or voltage amplitude at the magnetically defined anatomical sites is displayed with on-line data acquisition. This display can be manipulated to facilitate viewing from any angle. Altering the zoom control, triangle fill threshold, clipping plane, or color range can all enhance the display of a more focal area of interest. We documented the feasibility of using this single mapping catheter technique for localizing and ablating focal atrial tachycardias. In a consecutive series of 8 patients with 9 focal atrial tachycardias, the use of the single catheter CARTO mapping system was associated with ablation success in all but one patient who had a left atrial tachycardia localized to the medial aspect of the orifice of the left atrial appendage. Only low power energy delivery was used in this patient because of the

  2. Spatial Relationship of Focal Impulses, Rotors and Low Voltage Zones in Patients With Persistent Atrial Fibrillation.

    PubMed

    Schade, Anja; Nentwich, Karin; Costello-Boerrigter, Lisa C; Halbfass, Philipp; Mueller, Patrick; Roos, Markus; Barth, Sebastian; Krug, Joachim; Szoelloesi, Geza-Atilla; Lapp, Harald; Deneke, Thomas

    2016-05-01

    Focal impulses (FI) and rotors are sources associated with the initiation and maintenance of atrial fibrillation (AF). Their ablation results in a lower recurrence rate. The aim of this study was to characterize for the first time the spatial relationship between such sources and atrial low voltage zones (LVZ) representing fibrosis. Twenty-five consecutive patients undergoing their first ablation for persistent AF were included. Voltage mapping of both atria was done during AF. Endocardial mapping of FI and rotors (sources) was performed using a basket catheter and displayed using RhythmView(TM) (Topera Inc.) before ablation. Spatial relationship of LVZ and sources was analyzed. LVZs covered 13 ± 12% of right atrial (RA) endocardial surface and 33 ± 25% of left atrial (LA) endocardial surface. The median number of sources was 1 [1-3] in RA and 3 [1-4] in LA. Of LA sources, 18 (30%) were definitely not associated with LVZs or pulmonary vein (PV) antra. Of RA sources, 32 (84%) were remote from LVZ. During ablation of such sources substantial cycle length (CL) prolongation or AF conversion occurred in 11/23 patients (48%). Altogether, 8/11 (73%) of these pertinent sources were located remotely from LVZ and PV antra. There is a wide discrepancy in distribution of LVZ areas and sites of identified rotors. Site and incidence of FIRM sources appear to be unpredictable with atrial substrate mapping. Further prospective, randomized studies are necessary to elucidate the impact of additional ablation of such sources in patients with persistent or longstanding persistent AF. © 2016 Wiley Periodicals, Inc.

  3. Management of atrial fibrillation in seven European countries after the publication of the 2010 ESC Guidelines on atrial fibrillation: primary results of the PREvention oF thromboemolic events--European Registry in Atrial Fibrillation (PREFER in AF).

    PubMed

    Kirchhof, Paulus; Ammentorp, Bettina; Darius, Harald; De Caterina, Raffaele; Le Heuzey, Jean-Yves; Schilling, Richard John; Schmitt, Josef; Zamorano, Jose Luis

    2014-01-01

    We sought to describe the management of patients with atrial fibrillation (AF) in Europe after the release of the 2010 AF Guidelines of the European Society of Cardiology. The PREFER in AF registry enrolled consecutive patients with AF from January 2012 to January 2013 in 461 centres in seven European countries. Seven thousand two hundred and forty-three evaluable patients were enrolled, aged 71.5 ± 11 years, 60.1% male, CHA2DS2VASc score 3.4 ± 1.8 (mean ± standard deviation). Thirty per cent patients had paroxysmal, 24.0% had persistent, 7.2% had long-standing persistent, and 38.8% had permanent AF. Oral anticoagulation was used in the majority of patients: 4799 patients (66.3%) received a vitamin K antagonist (VKA) as mono-therapy, 720 patients a combination of VKA and antiplatelet agents (9.9%), 442 patients (6.1%) a new oral anticoagulant drugs (NOAC). Antiplatelet agents alone were given to 808 patients (11.2%), no antithrombotic therapy to 474 patients (6.5%). Of 7034 evaluable patients, 5530 (78.6%) patients were adequately rate controlled (mean heart rate 60-100 bpm). Half of the patients (50.7%) received rhythm control therapy by electrical cardioversion (18.1%), pharmacological cardioversion (19.5%), antiarrhythmic drugs (amiodarone 24.1%, flecainide or propafenone 13.5%, sotalol 5.5%, dronedarone 4.0%), and catheter ablation (5.0%). The management of AF patients in 2012 has adapted to recent evidence and guideline recommendations. Oral anticoagulant therapy with VKA (majority) or NOACs is given to over 80% of eligible patients, including those at risk for bleeding. Rate is often adequately controlled, and rhythm control therapy is widely used.

  4. Three-dimensional rotational angiography of the left atrium and the oesophagus: the short-term mobility of the oesophagus and the stability of the fused three-dimensional model of the left atrium and the oesophagus during catheter ablation for atrial fibrillation.

    PubMed

    Starek, Zdenek; Lehar, Frantisek; Jez, Jiri; Scurek, Martin; Wolf, Jiri; Kulik, Tomas; Zbankova, Alena; Novak, Miroslav

    2017-08-01

    The objective of this study was to evaluate the mobility of the oesophagus and the stability of the three-dimensional (3D) model of the oesophagus using 3D rotational angiography (3DRA) of the left atrium (LA) and the oesophagus, fused with live fluoroscopy during catheter ablation for atrial fibrillation. From March 2015 to September 2015, 3DRA of the LA and the oesophagus was performed in 33 patients before catheter ablation for atrial fibrillation. Control contrast oesophagography was performed every 30 min. The positions of the oesophagograms and the 3D model of the LA and the oesophagus were repeatedly measured and compared with the spine. The average shift of the oesophagus ranged from 2.7 ± 2.2 to 5.0 ± 3.5 mm. The average real-time oesophageal shift ranged from 2.7 ± 2.2 to 3.8 ± 3.4 mm. No significant shift was detected until the 90th minute of the procedure. The average shift of the 3D model of the LA and the oesophagus ranged from 1.4 ± 1.8 to 3.3 ± 3.0 mm (right-left direction) and from 0.9 ± 1.2 to 2.2 ± 1.3 mm (craniocaudal direction). During the 2 h procedure, there were no significant shifts of the model. During catheter ablation for atrial fibrillation, there is no significant change in the position of the oesophagus until the 90th minute of the procedure and no significant shift in the 3D model of the LA and the oesophagus. The 3D model of the oesophagus reliably depicts the position of the oesophagus during the entire procedure. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2016. For permissions please email: journals.permissions@oup.com.

  5. Ultrasound detection of cavitation as a phenomenon common to intervention devices causing tissue ablation

    NASA Astrophysics Data System (ADS)

    Bach, David S.; Armstrong, William F.; Erbel, Raimund; Ellis, Stephen G.; Sousa, Joao; Rosenschein, Uri

    1992-08-01

    Cavitation previously has been observed in association with ultrasonic angioplasty and high- frequency rotational atherectomy. This study evaluates the production of cavitation accompanying the use of several catheter-based devices under development or in current use in the practice of interventional cardiology. Catheters were examined in an in vitro model, and cavitation was evaluated using standard ultrasound imaging equipment. Cavitation was detected with each of the devices that effects tissue ablation, but not tissue resection. Devices produced characteristic patterns of cavitation dependent on the mode of energy release of the device. The size, but not the intensity, of the cavitation effect was proportional to the energy output of the devices. The precise role of cavitation in the mechanism of tissue ablation remains uncertain.

  6. Feasibility, Safety and Efficacy of a Novel Pre-Shaped Nitinol Esophageal Deviator to Successfully Deflect the Esophagus and Ablate Left Atrium without Esophageal Temperature Rise during Atrial Fibrillation Ablation - The DEFLECT GUT study.

    PubMed

    Parikh, Valay; Swarup, Vijay; Hantla, Jacob; Vuddanda, Venkat; Dar, Tawseef; Yarlagadda, Bharath; Di Biase, Luigi; Al-Ahmad, Amin; Natale, Andrea; Lakkireddy, Dhanunjaya

    2018-04-17

    Esophageal thermal injury is a feared complication of radiofrequency ablation (RFA) for atrial fibrillation (AF). Rise in luminal esophageal temperature (LET) limits the ability to deliver RF energy on posterior wall of LA. The aim of this registry was to evaluate feasibility, safety and efficacy of a mechanical esophageal deviation (ED) tool during AF ablation. We evaluated 687 patients who underwent RFA for AF. In 209 patients, EsoSure® was used to deflect esophagus away from ablation site. Propensity-score matching was performed to obtain 180 patients each in ED and non-ED arms. ED was used for LET rise seen in 61.7% (111/180) patients and was used if esophagus was in the line of ablation on fluoroscopy in 38.3% (69/180) patients. The mean deviation of trailing edge of esophagus with EsoSure® was 2.45 ± 0.9 cm (range: 1-4.5 cm). LET rise >1°C was significantly lower in ED than non-ED group (3% vs 79.4%, p<0.001). Mean LET rise (ED 0.34 ± 0.59 vs non-ED 1.66 ± 0.54, p<0.001). Intra-procedural success of PVAI, was slightly improved in ED arm than in non-ED arm without statistical significance. AF recurrence was lower in ED arm at 3-month, 6-month and 1-year follow-up than non-ED arm. No ED-related complications were noted. Mechanical displacement of esophagus with EsoSure® appears to be feasible, safe and efficacious in enabling adequate RF energy delivery to posterior wall of LA without significant LET rise and obvious clinical signs of esophageal injury. Copyright © 2018. Published by Elsevier Inc.

  7. Role of Echocardiography in the Management and Prognosis of Atrial Fibrillation

    PubMed Central

    Silverman, David I; Ayirala, Srilatha R; Manning, Warren J

    2012-01-01

    Echocardiography plays a longstanding and vital role in the management of atrial fibrillation (AF). Advances in 2D imaging, Doppler echocardiography and strain imaging have all contributed to major progress in AF treatment. Echocardiographically measured left atrial (LA) volume is a powerful predictor of maintenance of sinus rhythm following cardioversion as well as risk of thrombus formation and thromboembolism. Doppler derived parameters of atrial mechanical function including atrial ejection force provide related prognostic information. Transesophageal echocardiocardiograpy (TEE) guided cardioversion of AF allows for rapid conversion to sinus rhythm without prolonged oral anticoagulation, and TEE serves as a useful tool during catheter ablation of AF and atrial flutter. Newer measures derived from speckle tracking offer great promise in further improving the care of patients with AF. PMID:28496715

  8. Trends in hospitalization for atrial fibrillation: epidemiology, cost, and implications for the future.

    PubMed

    Sheikh, Azfar; Patel, Nileshkumar J; Nalluri, Nikhil; Agnihotri, Kanishk; Spagnola, Jonathan; Patel, Aashay; Asti, Deepak; Kanotra, Ritesh; Khan, Hafiz; Savani, Chirag; Arora, Shilpkumar; Patel, Nilay; Thakkar, Badal; Patel, Neil; Pau, Dhaval; Badheka, Apurva O; Deshmukh, Abhishek; Kowalski, Marcin; Viles-Gonzalez, Juan; Paydak, Hakan

    2015-01-01

    Atrial fibrillation (AF) is the most prevalent arrhythmia worldwide and the most common arrhythmia leading to hospitalization. Due to a substantial increase in incidence and prevalence of AF over the past few decades, it attributes to an extensive economic and public health burden. The increasing number of hospitalizations, aging population, anticoagulation management, and increasing trend for disposition to a skilled facility are drivers of the increasing cost associated with AF. There has been significant progress in AF management with the release of new oral anticoagulants, use of left atrial catheter ablation, and novel techniques for left atrial appendage closure. In this article, we aim to review the trends in epidemiology, hospitalization, and cost of AF along with its future implications on public health. Published by Elsevier Inc.

  9. Long-term survival in patients undergoing cardiac resynchronization therapy: the importance of performing atrio-ventricular junction ablation in patients with permanent atrial fibrillation

    PubMed Central

    Gasparini, Maurizio; Auricchio, Angelo; Metra, Marco; Regoli, François; Fantoni, Cecilia; Lamp, Barbara; Curnis, Antonio; Vogt, Juergen; Klersy, Catherine

    2008-01-01

    Aims To investigate the effects of cardiac resynchronization therapy (CRT) on survival in heart failure (HF) patients with permanent atrial fibrillation (AF) and the role of atrio-ventricular junction (AVJ) ablation in these patients. Methods and results Data from 1285 consecutive patients implanted with CRT devices are presented: 1042 patients were in sinus rhythm (SR) and 243 (19%) in AF. Rate control in AF was achieved by either ablating the AVJ in 118 patients (AVJ-abl) or prescribing negative chronotropic drugs (AF-Drugs). Compared with SR, patients with AF were significantly older, more likely to be non-ischaemic, with higher ejection fraction, shorter QRS duration, and less often received ICD back-up. During a median follow-up of 34 months, 170/1042 patients in SR and 39/243 in AF died (mortality: 8.4 and 8.9 per 100 person-year, respectively). Adjusted hazard ratios were similar for all-cause and cardiac mortality [0.9 (0.57–1.42), P = 0.64 and 1.00 (0.60–1.66) P = 0.99, respectively]. Among AF patients, only 11/118 AVJ-abl patients died vs. 28/125 AF-Drugs patients (mortality: 4.3 and 15.2 per 100 person-year, respectively, P < 0.001). Adjusted hazard ratios of AVJ-abl vs. AF-Drugs was 0.26 [95% confidence interval (CI) 0.09–0.73, P = 0.010] for all-cause mortality, 0.31 (95% CI 0.10–0.99, P = 0.048) for cardiac mortality, and 0.15 (95% CI 0.03–0.70, P = 0.016) for HF mortality. Conclusion Patients with HF and AF treated with CRT have similar mortality compared with patients in SR. In AF, AVJ ablation in addition to CRT significantly improves overall survival compared with CRT alone, primarily by reducing HF death. PMID:18390869

  10. Enhanced Radiofrequency Ablation With Magnetically Directed Metallic Nanoparticles.

    PubMed

    Nguyen, Duy T; Tzou, Wendy S; Zheng, Lijun; Barham, Waseem; Schuller, Joseph L; Shillinglaw, Benjamin; Quaife, Robert A; Sauer, William H

    2016-05-01

    Remote heating of metal located near a radiofrequency ablation source has been previously demonstrated. Therefore, ablation of cardiac tissue treated with metallic nanoparticles may improve local radiofrequency heating and lead to larger ablation lesions. We sought to evaluate the effect of magnetic nanoparticles on tissue sensitivity to radiofrequency energy. Ablation was performed using an ablation catheter positioned with 10 g of force over prepared ex vivo specimens. Tissue temperatures were measured and lesion volumes were acquired. An in vivo porcine thigh model was used to study systemically delivered magnetically guided iron oxide (FeO) nanoparticles during radiofrequency application. Magnetic resonance imaging and histological staining of ablated tissue were subsequently performed as a part of ablation lesion analysis. Ablation of ex vivo myocardial tissue treated with metallic nanoparticles resulted in significantly larger lesions with greater impedance changes and evidence of increased thermal conductivity within the tissue. Magnet-guided localization of FeO nanoparticles within porcine thigh preps was demonstrated by magnetic resonance imaging and iron staining. Irrigated ablation in the regions with greater FeO, after FeO infusion and magnetic guidance, created larger lesions without a greater incidence of steam pops. Metal nanoparticle infiltration resulted in significantly larger ablation lesions with altered electric and thermal conductivity. In vivo magnetic guidance of FeO nanoparticles allowed for facilitated radiofrequency ablation without direct infiltration into the targeted tissue. Further research is needed to assess the clinical applicability of this ablation strategy using metallic nanoparticles for the treatment of cardiac arrhythmias. © 2016 American Heart Association, Inc.

  11. High incidence of echocardiographic abnormalities of the interatrial septum in patients undergoing ablation for atrial fibrillation.

    PubMed

    Schernthaner, Christiana; Danmayr, Franz; Daburger, Apollonia; Eichinger, Jörg; Hammerer, Matthias; Strohmer, Bernhard

    2013-04-01

    Atrial fibrosis or fatty deposition is known to increase the propensity for the development of atrial fibrillation (AF). Apart from the pulmonic veins, the interatrial septum (IAS) might play a role in the maintenance of AF. In contrast to left atrial anatomy and adjacent veins, the IAS cannot be visualized in detail with computed tomography. Thus, preprocedural transesophageal echocardiography (TEE) may provide important morphologic information beyond exclusion from atrial thrombi. The study comprised 108 consecutive patients (mean age 60 ± 11 years; 98 men). AF was paroxysmal in 91 (84%) and persistent in 17 (16%) patients. We investigated the morphological characteristics of the IAS by TEE in patients who underwent radiofrequency ablation of AF. The IAS was structurally abnormal in 46 (43%) patients, showing the following echocardiograhic findings: atrial septal hypermobility or aneurysm (n = 27) associated with a patent foramen ovale (PFO) (n = 11) or with a small atrial septal defect (ASD) (n = 2), a septal flap associated with a PFO or an ASD (n = 8), and an abnormally thickened IAS (n = 12). A thrombus in the left atrial appendage was discovered in only 2 (2%) patients. A structurally abnormal IAS was diagnosed in nearly half of the patients undergoing ablation therapy for AF. The information obtained by TEE is mandatory to exclude left atrial thrombi prior the ablation procedure. Moreover, detailed knowledge of morphologic characteristics of the IAS facilitates an optimized and safe performance of the transseptal puncture using long sheaths with large diameters. © 2012, Wiley Periodicals, Inc.

  12. Radiofrequency Thermal Ablation Heat Energy Transfer in an Ex-Vivo Model.

    PubMed

    Thakur, Shivani; Lavito, Sandi; Grobner, Elizabeth; Grobner, Mark

    2017-12-01

    Little work has been done to consider the temperature changes and energy transfer that occur in the tissue outside the vein with ultrasound-guided vein ablation therapy. In this experiment, a Ex-Vivo model of the human calf was used to analyze heat transfer and energy degradation in tissue surrounding the vein during endovascular radiofrequency ablation (RFA). A clinical vein ablation protocol was used to determine the tissue temperature distribution in 10 per cent agar gel. Heat energy from the radiofrequency catheter was measured for 140 seconds at fixed points by four thermometer probes placed equidistant radially at 0.0025, 0.005, and 0.01 m away from the RFA catheter. The temperature rose 1.5°C at 0.0025 m, 0.6°C at 0.005 m, and 0.0°C at 0.01 m from the RFA catheter. There was a clinically insignificant heat transfer at the distances evaluated, 1.4 ± 0.2 J/s at 0.0025 m, 0.7 ± 0.3 J/s at 0.0050 m, and 0.3 ± 0.0 J/s at 0.01 m. Heat degradation occurred rapidly: 4.5 ± 0.5 J (at 0.0025 m), 4.0 ± 1.6 J (at 0.0050 m), and 3.9 ± 3.6 J (at 0.01 m). Tumescent anesthesia injected one centimeter around the vein would act as a heat sink to absorb the energy transferred outside the vein to minimize tissue and nerve damage and will help phlebologists strategize options for minimizing damage.

  13. Thulium fiber laser recanalization of occluded ventricular catheters in an ex vivo tissue model

    NASA Astrophysics Data System (ADS)

    Hutchens, Thomas C.; Gonzalez, David A.; Hardy, Luke A.; McLanahan, C. Scott; Fried, Nathaniel M.

    2017-04-01

    Hydrocephalus is a chronic medical condition that occurs in individuals who are unable to reabsorb cerebrospinal fluid (CSF) created within the ventricles of the brain. Treatment requires excess CSF to be diverted from the ventricles to another part of the body, where it can be returned to the vascular system via a shunt system beginning with a catheter within the ventricle. Catheter failures due to occlusion by brain tissues commonly occur and require surgical replacement of the catheter. In this preliminary study, minimally invasive clearance of occlusions is explored using an experimental thulium fiber laser (TFL), with comparison to a conventional holmium: yttrium aluminium garnet (YAG) laser. The TFL utilizes smaller optical fibers (<200-μm OD) compared with holmium laser (>450-μm OD), providing critical extra cross-sectional space within the 1.2-mm-inner-diameter ventricular catheter for simultaneous application of an endoscope for image guidance and a saline irrigation tube for visibility and safety. TFL ablation rates using 100-μm core fiber, 33-mJ pulse energy, 500-μs pulse duration, and 20- to 200-Hz pulse rates were compared to holmium laser using a 270-μm core fiber, 325-mJ, 300-μs, and 10 Hz. A tissue occluded catheter model was prepared using coagulated egg white within clear silicone tubing. An optimal TFL pulse rate of 50 Hz was determined, with an ablation rate of 150 μm/s and temperature rise outside the catheter of ˜10°C. High-speed camera images were used to explore the mechanism for removal of occlusions. Image guidance using a miniature, 0.7-mm outer diameter, 10,000 pixel endoscope was explored to improve procedure safety. With further development, simultaneous application of TFL with small fibers, miniature endoscope for image guidance, and irrigation tube for removal of tissue debris may provide a safe, efficient, and minimally invasive method of clearing occluded catheters in the treatment of hydrocephalus.

  14. Organized Atrial Tachycardias after Atrial Fibrillation Ablation

    PubMed Central

    Castrejón-Castrejón, Sergio; Ortega, Marta; Pérez-Silva, Armando; Doiny, David; Estrada, Alejandro; Filgueiras, David; López-Sendón, José L.; Merino, José L.

    2011-01-01

    The efficacy of catheter-based ablation techniques to treat atrial fibrillation is limited not only by recurrences of this arrhythmia but also, and not less importantly, by new-onset organized atrial tachycardias. The incidence of such tachycardias depends on the type and duration of the baseline atrial fibrillation and specially on the ablation technique which was used during the index procedure. It has been repeatedly reported that the more extensive the left atrial surface ablated, the higher the incidence of organized atrial tachycardias. The exact origin of the pathologic substrate of these trachycardias is not fully understood and may result from the interaction between preexistent regions with abnormal electrical properties and the new ones resultant from radiofrequency delivery. From a clinical point of view these atrial tachycardias tend to remit after a variable time but in some cases are responsible for significant symptoms. A precise knowledge of the most frequent types of these arrhythmias, of their mechanisms and components is necessary for a thorough electrophysiologic characterization if a new ablation procedure is required. PMID:21941669

  15. Atrial fibrillation and stroke: the evolving role of rhythm control.

    PubMed

    Patel, Taral K; Passman, Rod S

    2013-06-01

    Atrial fibrillation (AF) remains a major risk factor for stroke. Unfortunately, clinical trials have failed to demonstrate that a strategy of rhythm control--therapy to maintain normal sinus rhythm (NSR)--reduces stroke risk. The apparent lack of benefit of rhythm control likely reflects the difficulty in maintaining NSR using currently available therapies. However, there are signals from several trials that the presence of NSR is indeed beneficial and associated with better outcomes related to stroke and mortality. Most electrophysiologists feel that as rhythm control strategies continue to improve, the crucial link between rhythm control and stroke reduction will finally be demonstrated. Therefore, AF specialists tend to be aggressive in their attempts to maintain NSR, especially in patients who have symptomatic AF. A step-wise approach from antiarrhythmic drugs to catheter ablation to cardiac surgery is generally used. In select patients, catheter ablation or cardiac surgery may supersede antiarrhythmic drugs. The choice depends on the type of AF, concurrent heart disease, drug toxicity profiles, procedural risks, and patient preferences. Regardless of strategy, given the limited effectiveness of currently available rhythm control therapies, oral anticoagulation is still recommended for stroke prophylaxis in AF patients with other stroke risk factors. Major challenges in atrial fibrillation management include selecting patients most likely to benefit from rhythm control, choosing specific antiarrhythmic drugs or procedures to achieve rhythm control, long-term monitoring to gauge the efficacy of rhythm control, and determining which (if any) patients may safely discontinue anticoagulation if long-term NSR is achieved.

  16. Obstructive Sleep Apnoea and Atrial Fibrillation

    PubMed Central

    Zhang, Ling; Hou, Yuemei; Po, Sunny S

    2015-01-01

    Atrial fibrillation (AF) is the most prevalent cardiac arrhythmia and is associated with significant morbidity and mortality. Obstructive sleep apnoea (OSA) is common among patients with AF. Growing evidence suggests that OSA is associated with the initiation and maintenance of AF. This association is independent of obesity, body mass index and hypertension. OSA not only promotes initiation of AF but also has a significant negative impact on the treatment of AF. Patients with untreated OSA have a higher AF recurrence rate with drug therapy, electrical cardioversion and catheter ablation. Treatment with continuous positive airway pressure (CPAP) has been shown to improve AF control in patients with OSA. In this article, we will review and discuss the pathophysiological mechanisms of OSA that may predispose OSA patients to AF as well as the standard and emerging therapies for patients with both OSA and AF. PMID:26835094

  17. Magnetic navigation in adults with atrial isomerism (heterotaxy syndrome) and supraventricular arrhythmias.

    PubMed

    Suman-Horduna, Irina; Babu-Narayan, Sonya V; Ueda, Akiko; Mantziari, Lilian; Gujic, Marko; Marchese, Procolo; Dimopoulos, Konstantinos; Gatzoulis, Michael A; Rigby, Michael L; Ho, Siew Yen; Ernst, Sabine

    2013-06-01

    We analysed the type and mechanism of supraventricular arrhythmias encountered in a series of symptomatic adults with atrial isomerism undergoing catheter ablation procedures. The study population included consecutive adults with atrial isomerism who had previously undergone surgical repair or palliation of the associated anomalies. Patients underwent electrophysiological study for symptomatic arrhythmia in our institution between 2010 and 2012 using magnetic navigation in conjunction with CARTO RMT and three-dimensional (3D) image integration. Eight patients (five females) with a median age of 33 years [interquartile range (IQR) 24-39] were studied. Access to the cardiac chambers of interest was obtained retrogradely via the aorta using remotely navigated magnetic catheters in six patients. Radiofrequency ablation successfully targeted twin atrioventricular (AV) nodal reentrant tachycardia in two patients, atrial fibrillation (AF) in three, focal atrial tachycardia (AT) mainly originating in the left-sided atrium in four patients, and macro-reentrant AT dependent on a right-sided inferior isthmus in three patients. The median fluoroscopy time was 3.0 min (IQR 2-11). After a median follow-up of 10 months (IQR 6-21), five of the ablated patients are free from arrhythmia; two patients experienced episodes of self-terminated AF and AT, respectively, within one month post-ablation; the remaining patient had only non-sustained AT during the electrophysiological study and was managed medically. Various supraventricular tachycardia mechanisms are possible in adults with heterotaxy syndrome, all potentially amenable to radiofrequency ablation. The use of remote magnetic navigation along with 3D mapping facilitated the procedures and resulted in a short radiation time.

  18. [Combined left atrial appendage percutaneous closure and atrial fibrillation ablation: a single center experience].

    PubMed

    Pelissero, Elisa; Giuggia, Marco; Todaro, Maria Chiara; Trapani, Giuseppe; Giordano, Benedetta; Senatore, Gaetano

    2017-12-01

    We evaluated long-term safety and efficacy of concomitant left atrial appendage (LAA) closure and atrial fibrillation (AF) ablation. From February 2013 to June 2017, all patients referred for AF ablation and LAA closure (group 1) were enrolled in the study and compared with a matched control group undergoing AF ablation only (group 2). Pulmonary vein isolation was achieved in all cases with radiofrequency or cryoballoon. LAA was occluded with Watchman or Amplatzer Cardiac Plug or Amulet (ACP) devices. All patients were treated with oral anticoagulation therapy for at least 3 months after the procedure ("blanking period"), and then switched to dual antiplatelet therapy with aspirin and clopidogrel for other 3 months, and then to single antiplatelet therapy with aspirin in case of LAA closure, while group 2 was treated with long-term oral anticoagulation therapy according to CHA2DS2-VASc score. Follow-up was performed with transesophageal echocardiography and clinical visit at 3, 6 and 12 months after the procedure. AF burden was evaluated by loop recorder or pacemaker interrogation in all patients. Overall, 42 patients were enrolled, 21 in each group. Mean age was 66.86 ± 10.35 years in group 1 vs 68.42 ± 10.61 in group 2 (p=NS); mean CHA2DS2-VASc score was 2.8 ± 1.22 in group 1 vs 2.01 ± 0.93 in group 2 (p=NS), mean HAS-BLED score was 3.2 ± 0.83 in group 1 vs 3.1 ± 0.95 in group 2 (p=NS). Persistent AF was present in 80% of patients in group 1 and in 85% in group 2. LAA closure was successful in all cases (14 Watchman, 7 ACP devices). Procedural and fluoroscopy times were shorter in group 2 (68 ± 17 vs 52 ± 15 min, p <0.05; 23 ± 5 vs 18 ± 3 min, p <0.05, respectively). No procedural complications were observed in group 2, while in group 1 one case of self-terminating pericardial effusion and one arteriovenous fistula were observed. At a mean follow-up of 14.93 ± 10.05 months, complete seal of LAA was documented in all patients, with neither dislocations

  19. Calcified lesion modeling for excimer laser ablation

    NASA Astrophysics Data System (ADS)

    Scott, Holly A.; Archuleta, Andrew; Splinter, Robert

    2009-06-01

    Objective: Develop a representative calcium target model to evaluate penetration of calcified plaque lesions during atherectomy procedures using 308 nm Excimer laser ablation. Materials and Methods: An in-vitro model representing human calcified plaque was analyzed using Plaster-of-Paris and cement based composite materials as well as a fibrinogen model. The materials were tested for mechanical consistency. The most likely candidate(s) resulting from initial mechanical and chemical screening was submitted for ablation testing. The penetration rate of specific multi-fiber catheter designs and a single fiber probe was obtained and compared to that in human cadaver calcified plaque. The effects of lasing parameters and catheter tip design on penetration speed in a representative calcified model were verified against the results in human cadaver specimens. Results: In Plaster of Paris, the best penetration was obtained using the single fiber tip configuration operating at 100 Fluence, 120 Hz. Calcified human lesions are twice as hard, twice as elastic as and much more complex than Plaster of Paris. Penetration of human calcified specimens was highly inconsistent and varied significantly from specimen to specimen and within individual specimens. Conclusions: Although Plaster of Paris demonstrated predictable increases in penetration with higher energy density and repetition rate, it can not be considered a totally representative laser ablation model for calcified lesions. This is in part due to the more heterogeneous nature and higher density composition of cadaver intravascular human calcified occlusions. Further testing will require a more representative model of human calcified lesions.

  20. Modeling and Validation of the Three Dimensional Deflection of an MRI-Compatible Magnetically-Actuated Steerable Catheter

    PubMed Central

    Liu, Taoming; Poirot, Nate Lombard; Franson, Dominique; Seiberlich, Nicole; Griswold, Mark A.; Çavuşoğlu, M. Cenk

    2016-01-01

    Objective This paper presents the three dimensional kinematic modeling of a novel steerable robotic ablation catheter system. The catheter, embedded with a set of current-carrying micro-coils, is actuated by the magnetic forces generated by the magnetic field of the magnetic resonance imaging (MRI) scanner. Methods This paper develops a 3D model of the MRI actuated steerable catheter system by using finite differences approach. For each finite segment, a quasi-static torque-deflection equilibrium equation is calculated using beam theory. By using the deflection displacements and torsion angles, the kinematic model of the catheter system is derived. Results The proposed models are validated by comparing the simulation results of the proposed model with the experimental results of a hardware prototype of the catheter design. The maximum tip deflection error is 4.70 mm and the maximum root-mean-square (RMS) error of the shape estimation is 3.48 mm. Conclusion The results demonstrate that the proposed model can successfully estimate the deflection motion of the catheter. Significance The presented three dimensional deflection model of the magnetically controlled catheter design paves the way to efficient control of the robotic catheter for treatment of atrial fibrillation. PMID:26731519

  1. [Successful transcatheter ablation of fascicular potential in pediatric patients with left posterior fascicular tachycardia].

    PubMed

    Zeng, Shao-ying; Shi, Ji-jun; Li, Hong; Zhang, Zhi-wei; Li, Yu-fen

    2010-08-01

    To simplify the methods of transcatheter mapping and ablation in the pediatric patients with left posterior fascicular tachycardia. While in sinus rhythm, the fascicular potential can be mapped at the posterior septal region (1 - 2 cm below inferior margin of orifice of coronary sinus vein), which display a biphasic wave before ventricular wave, and exist equipotential lines between them. When the fascicular potential occurs 20 ms later than the bundle of His' potential, radiofrequency was applied. Before applying radiofrequency, catheter position must be observed using double angle viewing (LAO 45°RAO 30°), and it should be made sure that the catheter is not at His' bundle. If the electrocardiogram displays left posterior fascicular block, the correct region is identified and ablation can continue for 60 s. Electrocardiogram monitoring should continue for 24 - 48 hours after operation, and notice abnormal repolarization after termination of ventricular tachycardia. Aspirin [2 - 3 mg/(kg·d)] was used for 3 months, and antiarrhythmic drug was discontinued. Surface electrocardiogram, chest X-ray and ultrasound cardiography were rechecked 1 d after operation. Follow-up was made at 1 month and 3 months post-discharge. Recheck was made half-yearly or follow-up was done by phone from then on. Fifteen pediatric patients were ablated successfully, and their electrocardiograms all displayed left posterior fascicular block after ablation. None of the patients had recurrences during the 3 to 12 months follow-up period. In one case, the electrocardiogram did not change after applying radiofrequency ablation and the ventricular tachycardia remained; however, on second attempt after remapping, the electrocardiogram did change. The radiofrequency lasted for 90 seconds and ablation was successful. This case had no recurrences at 6 months follow-up. Transcatheter ablation of the fascicular potential in pediatric patients with left posterior fascicular tachycardia can simplify

  2. Wireless monitoring of reconstructed 12-lead ECG in atrial fibrillation patients enables differential diagnosis of recurrent arrhythmias.

    PubMed

    Vukajlovic, Dejan; Gussak, Ihor; George, Samuel; Simic, Goran; Bojovic, Bosko; Hadzievski, Ljupco; Stojanovic, Bojan; Angelkov, Lazar; Panescu, Dorin

    2011-01-01

    Differential diagnosis of symptomatic events in post-ablation atrial fibrillation (AF) patients (pts) is important; in particular, accurate, reliable detection of AF or atrial flutter (AFL) is essential. However, existing remote monitoring devices usually require attached leads and are not suitable for prolonged monitoring; moreover, most do not provide sufficient information to assess atrial activity, since they generally monitor only 1-3 ECG leads and rely on RR interval variability for AF diagnosis. A new hand-held, wireless, symptom-activated event monitor (CardioBip; CB) does not require attached leads and hence can be conveniently used for extended periods. Moreover, CB provides data that enables remote reconstruction of full 12-lead ECG data including atrial signal information. We hypothesized that these CB features would enable accurate remote differential diagnosis of symptomatic arrhythmias in post-ablation AF pts. 21 pts who underwent catheter ablation for AF were instructed to make a CB transmission (TX) whenever palpitations, lightheadedness, or similar symptoms occurred, and at multiple times daily when asymptomatic, during a 60 day post-ablation time period. CB transmissions (TXs) were analyzed blindly by 2 expert readers, with differences adjudicated by consensus. 7 pts had no symptomatic episodes during the monitoring period. 14 of 21 pts had symptomatic events and made a total of 1699 TX, 164 of which were during symptoms. TX quality was acceptable for rhythm diagnosis and atrial activity in 96%. 118 TX from 10 symptomatic pts showed AF (96 TX from 10 pts) or AFL (22 TX from 3 pts), and 46 TX from 9 pts showed frequent PACs or PVCs. No other arrhythmias were detected. Five pts made symptomatic TX during AF/AFL and also during PACs/PVCs. Use of CB during symptomatic episodes enabled detection and differential diagnosis of symptomatic arrhythmias. The ability of CB to provide accurate reconstruction of 12 L ECGs including atrial activity, combined

  3. Prevalence of right atrial non-pulmonary vein triggers in atrial fibrillation patients treated with thyroid hormone replacement therapy.

    PubMed

    Kim, Ki-Hun; Mohanty, Sanghamitra; Mohanty, Prasant; Trivedi, Chintan; Morris, Eli Hamilton; Santangeli, Pasquale; Bai, Rong; Al-Ahmad, Amin; Burkhardt, John David; Gallinghouse, Joseph G; Horton, Rodney; Sanchez, Javier E; Bailey, Shane; Hranitzky, Patrick M; Zagrodzky, Jason; Kim, Soo G; Di Biase, Luigi; Natale, Andrea

    2017-08-01

    Thyroid hormone (TH) is known to enhance arrhythmogenicity, and high-normal thyroid function is related with an increased recurrence of atrial fibrillation (AF) after catheter ablation. However, the impact of thyroid hormone replacement (THR) on AF ablation is not well known. This study evaluated 1163 consecutive paroxysmal AF patients [160 (14%) on THR and 1003 (86%) without THR] undergoing their first catheter ablation. A total of 146 patients on THR and 146 controls were generated by propensity matching, based on calculated risk factor scores, using a logistic model (age, sex, body mass index, and left atrium size). The presence of non-pulmonary vein (PV) triggers was disclosed by a high-dose isoproterenol challenge (up to 30 μg/min) after PV isolation. Clinical characteristics were not different between the groups. When compared to the control, non-PV triggers were significantly greater in the THR patients [112 (77%) vs. 47 (32%), P < 0.001], and most frequently originated from the right atrium (95 vs. 56%, P < 0.001). Other sources of non-PV triggers were the interatrial septum (25 vs. 11%, P = 0.002), coronary sinus (70 vs. 52%, P = 0.01), left atrial appendage (47 vs. 34%, P = 0.03), crista terminalis/superior vena cava (11 vs. 8%, P = 0.43), and mitral valve annulus (7 vs. 5%, P = 0.45) (THR vs. control), respectively. After mean follow-up of 14.7 ± 5.2 months, success rate was lower in patients on THR therapy [94 (64.4%)] compared to patients not receiving THR therapy [110 (75.3%), log-rank test value = 0.04]. Right atrial non-PV triggers were more prevalent in AF patients treated with THR. Elimination of non-PV triggers provided better arrhythmia-free survival in the non-THR group.

  4. Noninvasive Assessment of Tissue Heating During Cardiac Radiofrequency Ablation Using MRI Thermography

    PubMed Central

    Kolandaivelu, Aravindan; Zviman, Menekhem M.; Castro, Valeria; Lardo, Albert C.; Berger, Ronald D.; Halperin, Henry R.

    2010-01-01

    Background Failure to achieve properly localized, permanent tissue destruction is a common cause of arrhythmia recurrence after cardiac ablation. Current methods of assessing lesion size and location during cardiac radiofrequency ablation are unreliable or not suited for repeated assessment during the procedure. MRI thermography could be used to delineate permanent ablation lesions because tissue heating above 50°C is the cause of permanent tissue destruction during radiofrequency ablation. However, image artifacts caused by cardiac motion, the ablation electrode, and radiofrequency ablation currently pose a challenge to MRI thermography in the heart. In the current study, we sought to demonstrate the feasibility of MRI thermography during cardiac ablation. Methods and Results An MRI-compatible electrophysiology catheter and filtered radiofrequency ablation system was used to perform ablation in the left ventricle of 6 mongrel dogs in a 1.5-T MRI system. Fast gradient-echo imaging was performed before and during radiofrequency ablation, and thermography images were derived from the preheating and postheating images. Lesion extent by thermography was within 20% of the gross pathology lesion. Conclusions MR thermography appears to be a promising technique for monitoring lesion formation and may allow for more accurate placement and titration of ablation, possibly reducing arrhythmia recurrences. PMID:20657028

  5. Endovascular Radiofrequency Ablation for Varicose Veins

    PubMed Central

    2011-01-01

    or worse as other chronic diseases such as back pain and arthritis. Lower limb VV is a very common disease affecting adults – estimated to be the 7th most common reason for physician referral in the US. There is a very strong familial predisposition to VV. The risk in offspring is 90% if both parents affected, 20% when neither affected and 45% (25% boys, 62% girls) if one parent affected. The prevalence of VV worldwide ranges from 5% to 15% among men and 3% to 29% among women varying by the age, gender and ethnicity of the study population, survey methods and disease definition and measurement. The annual incidence of VV estimated from the Framingham Study was reported to be 2.6% among women and 1.9% among men and did not vary within the age range (40-89 years) studied. Approximately 1% of the adult population has a stasis ulcer of venous origin at any one time with 4% at risk. The majority of leg ulcer patients are elderly with simple superficial vein reflux. Stasis ulcers are often lengthy medical problems and can last for several years and, despite effective compression therapy and multilayer bandaging are associated with high recurrence rates. Recent trials involving surgical treatment of superficial vein reflux have resulted in healing and significantly reduced recurrence rates. Endovascular Radiofrequency Ablation for Varicose Veins RFA is an image-guided minimally invasive treatment alternative to surgical stripping of superficial venous reflux. RFA does not require an operating room or general anaesthesia and has been performed in an outpatient setting by a variety of medical specialties including surgeons and interventional radiologists. Rather than surgically removing the vein, RFA works by destroying or ablating the refluxing vein segment using thermal energy delivered through a radiofrequency catheter. Prior to performing RFA, color-flow Doppler ultrasonography is used to confirm and map all areas of venous reflux to devise a safe and effective

  6. The efficacy of intraoperative atrial radiofrequency ablation for atrial fibrillation during concomitant cardiac surgery-the Surgical Atrial Fibrillation Suppression (SAFS) Study.

    PubMed

    Veasey, Rick A; Segal, Oliver R; Large, Janet K; Lewis, Michael E; Trivedi, Uday H; Cohen, Andrew S; Hyde, Jonathan A J; Sulke, A Neil

    2011-10-01

    Studies assessing radiofrequency ablation (RFA) for atrial fibrillation (AF) performed at the time of concomitant cardiac surgery have reported high success rates. The efficacy of this treatment has primarily been determined by a single electrocardiogram (ECG) or 24-h Holter monitor at follow-up. We sought to assess the true efficacy of this procedure using prolonged cardiac rhythm monitoring. One hundred patients with paroxysmal (n = 47) and persistent AF (n = 53) requiring cardiac surgery were enrolled. Patients were clinically reviewed 6 weeks post-operatively and were monitored with 7-day Holter with full disclosure, 6 months post-surgery. A cohort of 50 patients also underwent 7 day Holter monitoring preoperatively. AF recurrence was defined as >30 s of AF. At 6 months, 75% of patients were in sinus rhythm according to a single ECG. However, only 62% of patients were free from AF on 7-day Holter; all AF episodes in these patients were asymptomatic. The procedure resulted in a significant decrease in AF burden from 56.2% at baseline to 27.5% at 6 months follow-up, (p < 0.001). Predictors of AF recurrence were (1) pre-operative AF duration; (2) persistent compared with paroxysmal AF; (3) increasing left atrial diameter and (4) requirement for mitral valve surgery. Surgical RFA for the treatment of AF, during concomitant cardiac surgery, is a successful procedure and significantly reduces AF burden. However, 13% of patients have asymptomatic AF episodes only identified with continuous monitoring. This has important implications for post-operative anti-arrhythmic and anticoagulant management and for the definition of surgical AF ablation success.

  7. Impact of attributed audit on procedural performance in cardiac electrophysiology catheter laboratory.

    PubMed

    Sawhney, V; Volkova, E; Shaukat, M; Khan, F; Segal, O; Ahsan, S; Chow, A; Ezzat, V; Finlay, M; Lambiase, P; Lowe, M; Dhinoja, M; Sporton, S; Earley, M J; Hunter, R J; Schilling, R J

    2018-06-01

    Audit has played a key role in monitoring and improving clinical practice. However, audit often fails to drive change as summative institutional data alone may be insufficient to do so. We hypothesised that the practice of attributed audit, wherein each individual's procedural performance is presented will have a greater impact on clinical practice. This hypothesis was tested in an observational study evaluating improvement in fluoroscopy times for AF ablation. Retrospective analyses of fluoroscopy times in AF ablations at the Barts Heart Centre (BHC) from 2012-2017. Fluoroscopy times were compared pre- and post- the introduction of attributed audit in 2012 at St Bartholomew's Hospital (SBH). In order to test the hypothesis, this concept was introduced to a second group of experienced operators from the Heart Hospital (HH) as part of a merger of the two institutions in 2015 and change in fluoroscopy times recorded. A significant drop in fluoroscopy times (33.3 ± 9.14 to 8.95 ± 2.50, p < 0.0001) from 2012-2014 was noted after the introduction of attributed audit. At the time of merger, a significant difference in fluoroscopy times between operators from the two centres was seen in 2015. Each operator's procedural performance was shared openly at the audit meeting. Subsequent audits showed a steady decrease in fluoroscopy times for each operator with the fluoroscopy time (min, mean±SD) decreasing from 13.29 ± 7.3 in 2015 to 8.84 ± 4.8 (p < 0.0001) in 2017 across the entire group. Systematic improvement in fluoroscopy times for AF ablation procedures was noted byevaluating individual operators' performance. Attributing data to physicians in attributed audit can promptsignificant improvement and hence should be adopted in clinical practice.

  8. Surgical ablation for atrial fibrillation for two decades: are the results of new techniques equivalent to the Cox maze III procedure?

    PubMed

    Stulak, John M; Suri, Rakesh M; Burkhart, Harold M; Daly, Richard C; Dearani, Joseph A; Greason, Kevin L; Joyce, Lyle D; Park, Soon J; Schaff, Hartzell V

    2014-05-01

    A significant evolution has occurred in surgical ablation for atrial fibrillation (AF) toward alternate energy sources, lesion sets, and approaches, with the intent of simplifying the Cox maze III operation and maintaining similar outcomes. Because no large comparative studies with long-term follow-up exist, we have reviewed our experience. From January 1993 to January 2011, 1540 patients underwent surgical ablation for AF. The operations were performed in conjunction with repair of congenital heart disease in 351 (30%) and adult-acquired disease in 1189 patients (70%). In the 1189 patients, preoperative AF was paroxysmal in 598 (50%) and persistent in 591 (50%). The energy sources included cut and sew in 521 (44%), cryothermy in 267 (22%), radiofrequency in 262 (22%), and a combination in 139 patients (12%). The lesion sets included biatrial in 810 (68%), isolated pulmonary vein isolation in 269 (23%), and isolated left atrial in 110 (9%). AF ablation was performed during isolated mitral valve surgery in 516 patients (43%). The median follow-up was 33 months (maximum, 20.3 years), and late rhythm follow-up was available for 80%. The cut and sew Cox maze III procedure was superior at each follow-up interval (P = .01, P = .03, and P < .001). On multivariate analysis, the cut and sew maze procedure was independently associated with less risk of recurrent AF at a follow-up period of 1 to 5 years (hazard ratio, 0.4; 95% confidence interval, 0.24-0.69; P < .001) and >5 years (hazard ratio, 0.23; 95% confidence interval, 0.12-0.42; P < .001) for all patients. When performed during isolated mitral valve surgery, the cut and sew Cox maze III was also independently associated with less risk of recurrent AF at >5 years (hazard ratio, 0.23; 95% confidence interval, 0.08-0.66; P = .007). The cut and sew Cox maze III procedure appears to offer significantly greater freedom from AF without antiarrhythmic medications compared with alternate energy sources and lesion

  9. Using Discrete Event Simulation to Model the Economic Value of Shorter Procedure Times on EP Lab Efficiency in the VALUE PVI Study.

    PubMed

    Kowalski, Marcin; DeVille, J Brian; Svinarich, J Thomas; Dan, Dan; Wickliffe, Andrew; Kantipudi, Charan; Foell, Jason D; Filardo, Giovanni; Holbrook, Reece; Baker, James; Baydoun, Hassan; Jenkins, Mark; Chang-Sing, Peter

    2016-05-01

    The VALUE PVI study demonstrated that atrial fibrillation (AF) ablation procedures and electrophysiology laboratory (EP lab) occupancy times were reduced for the cryoballoon compared with focal radiofrequency (RF) ablation. However, the economic impact associated with the cryoballoon procedure for hospitals has not been determined. Assess the economic value associated with shorter AF ablation procedure times based on VALUE PVI data. A model was formulated from data from the VALUE PVI study. This model used a discrete event simulation to translate procedural efficiencies into metrics utilized by hospital administrators. A 1000-day period was simulated to determine the accrued impact of procedure time on an institution's EP lab when considering staff and hospital resources. The simulation demonstrated that procedures performed with the cryoballoon catheter resulted in several efficiencies, including: (1) a reduction of 36.2% in days with overtime (422 days RF vs 60 days cryoballoon); (2) 92.7% less cumulative overtime hours (370 hours RF vs 27 hours cryoballoon); and (3) an increase of 46.7% in days with time for an additional EP lab usage (186 days RF vs 653 days cryoballoon). Importantly, the added EP lab utilization could not support the time required for an additional AF ablation procedure. The discrete event simulation of the VALUE PVI data demonstrates the potential positive economic value of AF ablation procedures using the cryoballoon. These benefits include more days where overtime is avoided, fewer cumulative overtime hours, and more days with time left for additional usage of EP lab resources.

  10. Stability of rotors and focal sources for human atrial fibrillation: focal impulse and rotor mapping (FIRM) of AF sources and fibrillatory conduction.

    PubMed

    Swarup, Vijay; Baykaner, Tina; Rostamian, Armand; Daubert, James P; Hummel, John; Krummen, David E; Trikha, Rishi; Miller, John M; Tomassoni, Gery F; Narayan, Sanjiv M

    2014-12-01

    Several groups report electrical rotors or focal sources that sustain atrial fibrillation (AF) after it has been triggered. However, it is difficult to separate stable from unstable activity in prior studies that examined only seconds of AF. We applied phase-based focal impulse and rotor mapping (FIRM) to study the dynamics of rotors/sources in human AF over prolonged periods of time. We prospectively mapped AF in 260 patients (169 persistent, 61 ± 12 years) at 6 centers in the FIRM registry, using baskets with 64 contact electrodes per atrium. AF was phase mapped (RhythmView, Topera, Menlo Park, CA, USA). AF propagation movies were interpreted by each operator to assess the source stability/dynamics over tens of minutes before ablation. Sources were identified in 258 of 260 of patients (99%), for 2.8 ± 1.4 sources/patient (1.8 ± 1.1 in left, 1.1 ± 0.8 in right atria). While AF sources precessed in stable regions, emanating activity including spiral waves varied from collision/fusion (fibrillatory conduction). Each source lay in stable atrial regions for 4,196 ± 6,360 cycles, with no differences between paroxysmal versus persistent AF (4,290 ± 5,847 vs. 4,150 ± 6,604; P = 0.78), or right versus left atrial sources (P = 0.26). Rotors and focal sources for human AF mapped by FIRM over prolonged time periods precess ("wobble") but remain within stable regions for thousands of cycles. Conversely, emanating activity such as spiral waves disorganize and collide with the fibrillatory milieu, explaining difficulties in using activation mapping or signal processing analyses at fixed electrodes to detect AF rotors. These results provide a rationale for targeted ablation at AF sources rather than fibrillatory spiral waves. © 2014 Wiley Periodicals, Inc.

  11. Sensitivity of reentrant driver localization to electrophysiological parameter variability in image-based computational models of persistent atrial fibrillation sustained by a fibrotic substrate

    NASA Astrophysics Data System (ADS)

    Deng, Dongdong; Murphy, Michael J.; Hakim, Joe B.; Franceschi, William H.; Zahid, Sohail; Pashakhanloo, Farhad; Trayanova, Natalia A.; Boyle, Patrick M.

    2017-09-01

    Atrial fibrillation (AF) is the most common sustained cardiac arrhythmia, causing morbidity and mortality in millions worldwide. The atria of patients with persistent AF (PsAF) are characterized by the presence of extensive and distributed atrial fibrosis, which facilitates the formation of persistent reentrant drivers (RDs, i.e., spiral waves), which promote fibrillatory activity. Targeted catheter ablation of RD-harboring tissues has shown promise as a clinical treatment for PsAF, but the outcomes remain sub-par. Personalized computational modeling has been proposed as a means of non-invasively predicting optimal ablation targets in individual PsAF patients, but it remains unclear how RD localization dynamics are influenced by inter-patient variability in the spatial distribution of atrial fibrosis, action potential duration (APD), and conduction velocity (CV). Here, we conduct simulations in computational models of fibrotic atria derived from the clinical imaging of PsAF patients to characterize the sensitivity of RD locations to these three factors. We show that RDs consistently anchor to boundaries between fibrotic and non-fibrotic tissues, as delineated by late gadolinium-enhanced magnetic resonance imaging, but those changes in APD/CV can enhance or attenuate the likelihood that an RD will anchor to a specific site. These findings show that the level of uncertainty present in patient-specific atrial models reconstructed without any invasive measurements (i.e., incorporating each individual's unique distribution of fibrotic tissue from medical imaging alongside an average representation of AF-remodeled electrophysiology) is sufficiently high that a personalized ablation strategy based on targeting simulation-predicted RD trajectories alone may not produce the desired result.

  12. Free-beam and contact laser soft-tissue ablation in urology.

    PubMed

    Tan, Andrew H H; Gilling, Peter J

    2003-10-01

    The ablation of tissue by laser has several applications in urology. Most of the published research has been concerned with the treatment of benign prostatic hyperplasia (BPH). Other applications studied include superficial upper- and lower-tract transitional-cell carcinoma, urethral and ureteral strictures, ureteropelvic junction stenosis, and posterior urethral valves. The attraction of laser ablation for the treatment of BPH lies with the decreased morbidity in comparison with standard transurethral electrocautery resection of the prostate and the ability to remove tissue immediately and therefore allow a more rapid progression to catheter removal and early voiding. The three main laser wavelengths used in urology for tissue ablation are the neodymium:yttrium-aluminum-garnet when used with contact tips or high-density power settings, the potassium-titanyl-phosphate, and the holmium:YAG. This article reviews the published literature on the use of these laser wavelengths in soft-tissue ablation, focusing on the treatment of BPH.

  13. Characteristics of Cavotricuspid Isthmus Ablation for Atrial Flutter Guided by Novel Parameters Using a Contact Force Catheter.

    PubMed

    Gould, Paul A; Booth, Cameron; Dauber, Kieran; Ng, Kevin; Claughton, Andrew; Kaye, Gerald C

    2016-12-01

    This study sought to investigate specific contact force (CF) parameters to guide cavotricuspid isthmus (CTI) ablation and compare the outcome with a historical control cohort. Patients (30) undergoing CTI ablation were enrolled prospectively in the Study cohort and compared with a retrospective Control cohort of 30 patients. Ablation in the Study cohort was performed using CF parameters >10 g and <40 g and a Force Time Integral (FTI) of 800 ± 10 g. The Control cohort underwent traditionally guided CTI ablation. Traditional parameters (electrogram and impedance change) were assessed in both cohorts. All ablations regardless of achieving targets were included in data analysis. Bidirectional CTI block was achieved in all of the Study and 27 of the Control cohort. Atrial flutter recurred in 3 (10%) patients (follow-up 564 ± 212 days) in the study cohort and in 3 (10%) patients (follow-up 804 ± 540 days) in the Control cohort. There were no major complications in either cohort. Traditional parameters correlated poorly with CF parameters. In the Study cohort, flutter recurrence was associated with significantly lower FTI and ablation duration, but was not associated with total average CF. CTI ablation can be safely performed using CF parameters guiding ablation, with similar long-term results to a historical ablation control group. Potentially CF parameters may provide adjunctive information to enable a more efficient CTI ablation. Further research is required to confirm this. © 2016 Wiley Periodicals, Inc.

  14. Towards multispectral endoscopic imaging of cardiac lesion assessment and classification for cardiac ablation therapy

    NASA Astrophysics Data System (ADS)

    Park, Soo Young; Singh-Moon, Rajinder P.; Hendon, Christine P.

    2018-02-01

    Pulmonary vein (PV) isolation is a critical procedure for the treatment and termination of atrial fibrillation (AF). The success of such treatment depends on the extent of tissue damage, where partial lesions can allow abnormal electrical conduction and risk relapse of AF. Proper evaluation of lesion delivery and ablation line continuity remains challenging with current techniques and in part limit procedural efficacy. A tool for direct visualization of endo-myocardial lesions in vivo could potentially reduce ambiguity in treatment location and extent and improve the overall fidelity of lesion sets. In this work, we introduce a method for wide-field visualization of myocardial tissue including the discernment of ablated and non-ablated regions using an endoscopic multispectral imaging system (EMIS). The system was designed to fit the working channel of most commercial sheathes (<4 Fr) and supported quadruple-wavelength reflectance imaging through a flexible fiber-bundle. A total of 50 endocardial lesions were created and imaged on nine swine hearts, ex vivo in addition to 15 lesions on human LA samples near PV regions. A pixel-wise linear discriminant analysis algorithm was developed to classify regions of ablation treatment based on calibrated EMI maps. Results show good agreement of treatment severity and spatial extent compared to post-hoc tissue vital staining.

  15. Safety and Efficacy of Cryoballoon Ablation for Paroxysmal Atrial Fibrillation in Japan - Results From the Japanese Prospective Post-Market Surveillance Study.

    PubMed

    Okumura, Ken; Matsumoto, Kazuo; Kobayashi, Yoshinori; Nogami, Akihiko; Hokanson, Robert B; Kueffer, Fred

    2016-07-25

    Outcomes of cryoballoon ablation for paroxysmal atrial fibrillation (PAF) have been reported in the Western countries but not in Japan. The CRYO-Japan PMS study was a single-arm, observational, multicenter, prospective study of the 2nd-generation cryoballoon Arctic Front Advance(TM). We evaluated device- and procedure-related complications and clinical outcomes at 6 months. The 616 patients (male, 72%; mean age, 63±11 years) were enrolled from 33 Japanese hospitals. Of all patients, 610 had PAF, and procedural data were analyzed in 607. A subset of 328 patients was followed for 6 months for the primary efficacy analysis. AF recurrence outside the 3-month blanking period or repeat ablation was considered treatment failure. Pulmonary vein isolation was achieved in 606/607 patients (99.8%); 1 patient (0.3%) had a repeat ablation during the blanking period. Freedom from AF at 6 months was 88.4% (95% CI: 84.1-91.6%). Device- and/or procedure-related adverse events included phrenic nerve injury unresolved at hospital discharge in 9/616 patients (1.5%), which resolved within 6 months in 7, pericardial effusion in 5/616 (0.8%), and tamponade in 4/616 (0.6%). One non-device-related death from pneumonia was reported 6 days post-procedure. Cryoballoon ablation is safe and effective for Japanese PAF patients, with 88.4% AF freedom at 6 months post-ablation. (Circ J 2016; 80: 1744-1749).

  16. Electrocardiographic left ventricular hypertrophy predicts recurrence of atrial arrhythmias after catheter ablation of paroxysmal atrial fibrillation.

    PubMed

    Li, Song-Nan; Wang, Lu; Dong, Jian-Zeng; Yu, Rong-Hui; Long, De-Yong; Tang, Ri-Bo; Sang, Cai-Hua; Jiang, Chen-Xi; Liu, Nian; Bai, Rong; Du, Xin; Ma, Chang-Sheng

    2018-06-01

    Left ventricular hypertrophy (LVH) is an independent predictor of new-onset atrial fibrillation. Whether LVH can predict the recurrence of arrhythmia after radiofrequency catheter ablation (RFCA) in patients with paroxysmal atrial fibrillation (PAF) remains unclear. PAF patients with baseline-electrocardiographic LVH has a higher recurrence rate after RFCA procedure compared with those without LVH. A total of 436 patients with PAF undergoing first RFCA were consecutively enrolled and clustered into 2 groups based on electrocardiogram (ECG) findings: non-ECG LVH (218 patients) and ECG LVH (218 patients). LVH was characterized by the Romhilt-Estes point score system; the score ≥5points were defined as LVH. At 42 months' (interquartile range, 18.0-60.0 months) follow-up after RFCA, 151 (69.3%) patients in the non-ECG LVH group and 108 (49.5%) patients in the ECG LVH group maintained sinus rhythm without using antiarrhythmic drugs (P < 0.001). Patients with ECG LVH tended to experience a much higher prevalence of stroke and recurrence of atrial arrhythmia episodes compared with those without ECG LVH (log-rank P < 0.001). Multivariate analysis found the presence of ECG LVH and left atrial diameter to be independent risk factors for recurrence after adjusting for confounding factors. The presence of ECG LVH was a strong and independent predictor of recurrence in patients with PAF following RFCA. © 2018 Wiley Periodicals, Inc.

  17. Targeted Prostate Thermal Therapy with Catheter-Based Ultrasound Devices and MR Thermal Monitoring

    NASA Astrophysics Data System (ADS)

    Diederich, Chris; Ross, Anthony; Kinsey, Adam; Nau, Will H.; Rieke, Viola; Butts Pauly, Kim; Sommer, Graham

    2006-05-01

    Catheter-based ultrasound devices have significant advantages for thermal therapy procedures, including potential for precise spatial and dynamic control of heating patterns to conform to targeted volumes. Interstitial and transurethral ultrasound applicators, with associated treatment strategies, were developed for thermal ablation of prostate combined with MR thermal monitoring. Four types of multielement transurethral applicators were devised, each with different levels of selectivity and intended therapeutic goals: sectored tubular transducer devices with fixed directional heating patterns; planar and lightly focused curvilinear devices with narrow heating patterns; and multi-sectored tubular devices capable of dynamic angular control without applicator movement. These devices are integrated with a 4 mm delivery catheter, incorporate an inflatable cooling balloon (10 mm OD) for positioning within the prostate and capable of rotation via an MR-compatible motor. Similarly, interstitial devices (2.4 mm OD) have been developed for percutaneous implantation with fixed directional heating patterns (e.g., 180 deg.). In vivo experiments in canine prostate (n=15) under MR temperature imaging were used to evaluate the heating technology and develop treatment strategies. MR thermal imaging in a 0.5 T interventional MRI was used to monitor temperature contours and thermal dose in multiple slices through the target volume. Sectored transurethral devices produce directional coagulation zones, extending 15-20 mm radial distance to the outer prostate capsule. The curvilinear applicator produces distinct 2-3 mm wide lesions, and with sequential rotation and modulated dwell time can precisely conform thermal ablation to selected areas or the entire prostate gland. Multi-sectored transurethral applicators can dynamically control the angular heating profile and target large regions of the gland in short treatment times without applicator manipulation. Interstitial implants with

  18. Consensus for the Treatment of Varicose Vein with Radiofrequency Ablation

    PubMed Central

    Joh, Jin Hyun; Kim, Woo-Shik; Jung, In Mok; Park, Ki-Hyuk; Lee, Taeseung; Kang, Jin Mo

    2014-01-01

    The objective of this paper is to introduce the schematic protocol of radiofrequency (RF) ablation for the treatment of varicose veins. Indication: anatomic or pathophysiologic indication includes venous diameter within 2–20 mm, reflux time ≥0.5 seconds and distance from the skin ≥5 mm or subfascial location. Access: it is recommended to access at or above the knee joint for great saphenous vein and above the mid-calf for small saphenous vein. Catheter placement: the catheter tip should be placed 2.0 cm inferior to the saphenofemoral or saphenopopliteal junction. Endovenous heat-induced thrombosis ≥class III should be treated with low-molecular weight heparin. Tumescent solution: the composition of solution can be variable (e.g., 2% lidocaine 20 mL+500 mL normal saline+bicarbonate 2.5 mL with/without epinephrine). Infiltration can be done from each direction. Ablation: two cycles’ ablation for the first proximal segment of saphenous vein and the segment with the incompetent perforators is recommended. The other segments should be ablated one time. During RF energy delivery, it is recommended to apply external compression. Concomitant procedure: It is recommended to do simultaneously ambulatory phlebectomy. For sclerotherapy, it is recommended to defer at least 2 weeks. Post-procedural management: post-procedural ambulation is encouraged to reduce the thrombotic complications. Compression stocking should be applied for at least 7 days. Minor daily activity is not limited, but strenuous activities should be avoided for 2 weeks. It is suggested to take showers after 24 hours and tub baths, swimming, or soaking in water after 2 weeks. PMID:26217628

  19. Renal denervation for improving outcomes of catheter ablation in patients with atrial fibrillation and hypertension: early experience.

    PubMed

    Pokushalov, Evgeny; Romanov, Alexander; Katritsis, Demosthenes G; Artyomenko, Sergey; Bayramova, Sevda; Losik, Denis; Baranova, Vera; Karaskov, Alexander; Steinberg, Jonathan S

    2014-07-01

    The potential role of renal denervation (RD) in patients with AF and less severe hypertension is unknown. The purpose of this study was to assess the potential role of RD as an adjunct to pulmonary vein isolation (PVI) in patients with atrial fibrillation (AF) and moderate resistant or severe resistant hypertension. The data for this study were obtained from 2 different prospective randomized studies, analyzed by meta-analysis. Patients with paroxysmal AF or persistent AF and moderate resistant hypertension (office blood pressure BP ≥140/90 mm Hg and <160/100 mm Hg; first study; n = 48) or severe resistant hypertension (≥160/100 mm Hg; second study; n = 38) were randomized to PVI or PVI with RD. At 12 months, 26 of the 41 PVI with RD patients (63%) were AF-free vs 16 of the 39 patients (41%) in the PVI-only group (P = .014). In patients with severe hypertension, 11 of the 18 PVI with RD patients (61%) vs 5 of the 18 PVI-only patients (28%) were AF-free (P = .03). For moderate hypertension, the differences were less dramatic: 11 of 21 (52%) vs 15 of 23 (65%) when RD added (P = .19). The superior efficacy of adding RD was most apparent in persistent AF and severe hypertension (hazard ratio 0.25, confidence interval 0.09-0.72, P = .01). Duration of the procedure and fluoroscopy were nonsignificantly longer in the RD group. RD may improve the results of PVI in patients with persistent AF and/or severe resistant hypertension. Copyright © 2014 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  20. Prostate thermal therapy with catheter-based ultrasound devices and MR thermal monitoring

    NASA Astrophysics Data System (ADS)

    Diederich, Chris J.; Nau, Will H.; Kinsey, Adam; Ross, Tony; Wootton, Jeff; Juang, Titania; Butts-Pauly, Kim; Ricke, Viola; Liu, Erin H.; Chen, Jing; Bouley, Donna M.; Van den Bosch, Maurice; Sommer, Graham

    2007-02-01

    Four types of transurethral applicators were devised for thermal ablation of prostate combined with MR thermal monitoring: sectored tubular transducer devices with directional heating patterns; planar and curvilinear devices with narrow heating patterns; and multi-sectored tubular devices capable of dynamic angular control without applicator movement. These devices are integrated with a 4 mm delivery catheter, incorporate an inflatable cooling balloon (10 mm OD) for positioning within the prostate and capable of rotation via an MR-compatible motor. Interstitial devices (2.4 mm OD) have been developed for percutaneous implantation with directional or dynamic angular control. In vivo experiments in canine prostate under MR temperature imaging were used to evaluate the heating technology and develop treatment control strategies. MR thermal imaging in a 0.5 T interventional MRI was used to monitor temperature and thermal dose in multiple slices through the target volume. Sectored tubular, planar, and curvilinear transurethral devices produce directional coagulation zones, extending 15-20 mm radial distance to the outer prostate capsule. Sequential rotation and modulated dwell time can conform thermal ablation to selected regions. Multi-sectored transurethral applicators can dynamically control the angular heating profile and target large regions of the gland in short treatment times without applicator manipulation. Interstitial implants with directional devices can be used to effectively ablate the posterior peripheral zone of the gland while protecting the rectum. The MR derived 52 °C and lethal thermal dose contours (t 43=240 min) allowed for real-time control of the applicators and effectively defined the extent of thermal damage. Catheter-based ultrasound devices, combined with MR thermal monitoring, can produce relatively fast and precise thermal ablation of prostate, with potential for treatment of cancer or BPH.