Sample records for age-related lens opacities

  1. Risk Factors for Cortical, Nuclear, Posterior Subcapsular, and Mixed Lens Opacities: The Los Angeles Latino Eye Study

    PubMed Central

    Richter, Grace M.; Torres, Mina; Choudhury, Farzana; Azen, Stanley P.; Varma, Rohit

    2012-01-01

    Purpose To identify socio-demographic and biological risk factors associated with having cortical, nuclear, posterior sub-capsular (PSC), and mixed lens opacities. Design Population-based, cross-sectional study Participants Five thousand nine hundred forty-five Latinos 40 years and older from 6 census tracts in Los Angeles, California. Methods Participants underwent an interview and detailed eye examination, including best-corrected visual acuity and slit-lamp assessment of lens opacities using the Lens Opacities Classification System II. Univariate and stepwise logistic regression analyses were used to identify independent risk factors associated with each type of lens opacity. Main Outcome Measures Odds ratios for socio-demographic and biological risk factors associated with cortical only, nuclear only, PSC only, and mixed lens opacities. Results Of the 5945 participants with gradable lenses, 468 had cortical only lens opacities, 217 had nuclear only lens opacities, 27 had PSC only opacities, and 364 had mixed lens opacities. Older age, higher hemoglobin A1c, and history of diabetes mellitus were independent risk factors for cortical only lens opacities. Older age, smoking, and myopic refractive error were independent risk factors for nuclear only lens opacities. Higher systolic blood pressure and history of diabetes were independent risk factors for posterior sub-capsular lens opacities. Older age, myopic refractive error, history of diabetes, higher systolic blood pressure, female gender, and presence of large drusen were independent risk factors for mixed lens opacities. Conclusions The modifiable and non-modifiable risk factors identified in this study provide insight into the mechanisms related to the development of lens opacification. Improved glycemic control, smoking cessation and prevention, and blood pressure control may help to reduce the risk of having lens opacities and their associated vision loss. PMID:22197433

  2. Eye Lens Opacities Among Physicians Occupationally Exposed to Ionizing Radiation.

    PubMed

    Auvinen, Anssi; Kivelä, Tero; Heinävaara, Sirpa; Mrena, Samy

    2015-08-01

    We compared the frequency of lens opacities among physicians with and without occupational exposure to ionizing radiation, and estimated dose-response between cumulative dose and opacities. We conducted ophthalmologic examinations of 21 physicians with occupational exposure to radiation and 16 unexposed physicians. Information on cumulative radiation doses (mean 111 mSv) was based on dosimeter readings recorded in a national database on occupational exposures. Lens changes were evaluated using the Lens Opacities Classification System II, with an emphasis on posterior subcapsular (PSC) and cortical changes. Among the exposed physicians, the prevalences of cortical and PSC changes were both 11% (3/21), and the corresponding frequencies in the unexposed group were 44% (n = 7) and 6% (n = 1). For dose-response analysis, the data were pooled with 29 exposed physicians from our previous study. No association of either type of lens changes with cumulative recorded dose was observed. Our findings do not indicate an increased frequency of lens opacities in physicians with occupational exposure to ionizing radiation. However, the subjects in this study have received relatively low doses and therefore the results do not exclude small increases in lens opacities or contradict the studies reporting increases among interventional cardiologists with materially higher cumulative doses. © The Author 2015. Published by Oxford University Press on behalf of the British Occupational Hygiene Society.

  3. A test of lens opacity as an indicator of preclinical Alzheimer Disease.

    PubMed

    Bei, Ling; Shui, Ying-Bo; Bai, Fang; Nelson, Suzanne K; Van Stavern, Gregory P; Beebe, David C

    2015-11-01

    Previous studies reported that characteristic lens opacities were present in Alzheimer Disease (AD) patients postmortem. We therefore determined whether cataract grade or lens opacity is related to the risk of Alzheimer dementia in participants who have biomarkers that predict a high risk of developing the disease. AD biomarker status was determined by positron emission tomography-Pittsburgh compound B (PET-PiB) imaging and cerebrospinal fluid (CSF) levels of Aβ42. Cognitively normal participants with a clinical dementia rating of zero (CDR = 0; N = 40) or with slight evidence of dementia (CDR = 0.5; N = 2) were recruited from longitudinal studies of memory and aging at the Washington University Knight Alzheimer's Disease Research Center. The age, sex, race, cataract type and cataract grade of all participants were recorded and an objective measure of lens light scattering was obtained for each eye using a Scheimpflug camera. Twenty-seven participants had no biomarkers of Alzheimer dementia and were CDR = 0. Fifteen participants had biomarkers indicating increased risk of AD, two of which were CDR = 0.5. Participants who were biomarker positive were older than those who were biomarker negative. Biomarker positive participants had more advanced cataracts and increased cortical light scattering, none of which reached statistical significance after adjustment for age. We conclude that cataract grade or lens opacity is unlikely to provide a non-invasive measure of the risk of developing Alzheimer dementia. Copyright © 2015 Elsevier Ltd. All rights reserved.

  4. Characteristics of Anterior Lens Opacities in Children

    PubMed Central

    Dixit, Lena; Puente, Michael; Yen, Kimberly G.

    2017-01-01

    Background: Anterior lens opacities (ALO) are found in 3-14% of pediatric patients with cataracts. No clear guidelines exist in the management and treatment of these cataracts. Objective: To evaluate pediatric patients with anterior lens opacities and assess rate of amblyopia and need for surgery over time. Methods: A retrospective chart review was performed on patients with unilateral and bilateral anterior lens opacities (ALOs) seen between January 2008 and December 2014. Size, location, and type of ALO were noted. Refractive error, necessity for treatment of amblyopia, and interventions were recorded. Results: A total of 31 patients were included in the study. 17 patients had unilateral ALOs and 14 had bilateral ALOs. The majority of the cataracts (90.3%) were centrally located. The most common type of cataract was the polar type of cataract and the vast majority (48.4%) was < 1mm in size. 38.7% of patients had concurrent ocular conditions and 9.7% had systemic associations. 28.6% of patients with bilateral cataracts and 35.3% of the patients with unilateral cataracts were treated for amblyopia. Three patients required cataract surgery. Conclusion: About half of anterior lens opacities are less than 1mm in size and the majority are of the polar type. Risk of amblyopia in these patients is higher than in the general population. Anisometropia is the most common cause of amblyopia. Ocular associations are seen at a relatively high frequency and systemic associations can occur but are uncommon. The need for surgical intervention is infrequent; however, growth of ALOs and associated cortical changes may be risk factors for surgery. PMID:28553426

  5. Age-related retention of fiber cell nuclei and nuclear fragments in the lens cortices of multiple species

    PubMed Central

    Pendergrass, William; Zitnik, Galynn; Urfer, Silvan R.

    2011-01-01

    the lens equator and were observable by the DAPI. These nuclei and nuclear fragments were seen from 12 months onward in all C57BL/6 and DBA/2 mice and to a lesser degree in the CBA, increasing in number and in space occupancy with increasing age. Preliminary results suggest that retention of nuclei in the C57BL/6 mouse is correlated with an age-related loss of DLAD from old lenses. Conclusions A very marked apparently light refractive condition caused by retained cortical nuclei and nuclear fragments is present in the lens cortices, increasing with age in the three strains of mice examined and in one of two strains of rats (BN). This condition was also seen in some old dogs and a few old humans. It may be caused by an age-related loss of DLAD, which is essential for nuclear DNA degradation in the lens. However, this condition does not develop in old BNF1 rats, or old monkeys and is only seen sporadically in humans. Thus, it can not be a universal cause for age related lens opacity or cataract presence, although it develops concurrently with opacity in mice. This phenomenon should be considered when using the old mouse as a model for human age-related cataract. PMID:22065920

  6. The ageing lens and cataract: a model of normal and pathological ageing

    PubMed Central

    Michael, R.; Bron, A. J.

    2011-01-01

    Cataract is a visible opacity in the lens substance, which, when located on the visual axis, leads to visual loss. Age-related cataract is a cause of blindness on a global scale involving genetic and environmental influences. With ageing, lens proteins undergo non-enzymatic, post-translational modification and the accumulation of fluorescent chromophores, increasing susceptibility to oxidation and cross-linking and increased light-scatter. Because the human lens grows throughout life, the lens core is exposed for a longer period to such influences and the risk of oxidative damage increases in the fourth decade when a barrier to the transport of glutathione forms around the lens nucleus. Consequently, as the lens ages, its transparency falls and the nucleus becomes more rigid, resisting the change in shape necessary for accommodation. This is the basis of presbyopia. In some individuals, the steady accumulation of chromophores and complex, insoluble crystallin aggregates in the lens nucleus leads to the formation of a brown nuclear cataract. The process is homogeneous and the affected lens fibres retain their gross morphology. Cortical opacities are due to changes in membrane permeability and enzyme function and shear-stress damage to lens fibres with continued accommodative effort. Unlike nuclear cataract, progression is intermittent, stepwise and non-uniform. PMID:21402586

  7. Exome Array Analysis of Nuclear Lens Opacity.

    PubMed

    Loomis, Stephanie J; Klein, Alison P; Lee, Kristine E; Chen, Fei; Bomotti, Samantha; Truitt, Barbara; Iyengar, Sudha K; Klein, Ronald; Klein, Barbara E K; Duggal, Priya

    2018-06-01

    Nuclear cataract is the most common subtype of age-related cataract, the leading cause of blindness worldwide. It results from advanced nuclear sclerosis, or opacity in the center of the optic lens, and is affected by both genetic and environmental risk factors, including smoking. We sought to understand the genetic factors associated with nuclear sclerosis through interrogation of rare and low frequency coding variants using exome array data. We analyzed Illumina Human Exome Array data for 1,488 participants of European ancestry in the Beaver Dam Eye Study who were without cataract surgery for association with nuclear sclerosis grade, controlling for age and sex. We performed single-variant regression analysis for 32,138 variants with minor allele frequency (MAF) ≥0.003. In addition, gene-based analysis of 11,844 genes containing at least two variants with MAF < 0.05 was performed using a gene-based unified burden and non-burden sequence kernel association test (SKAT-O). Additionally, both single-variant and gene-based analyses were analyzed stratified by smoking status. No single-variant test was statistically significant after Bonferroni correction (p < 1.6 × 10 -6 ; top single nucleotide polymorphism (SNP): rs144458991, p = 2.83 × 10 -5 ). Gene-based tests were suggestively associated with the gene RNF149 overall (p = 8.29 × 10 -6 ) and among never smokers (N = 790, p = 2.67 × 10 -6 ). This study did not find a significant genetic association with nuclear sclerosis, the possible association with the RNF149 gene highlights a potential candidate gene for future studies that aim to understand the genetic architecture of nuclear sclerosis.

  8. Epidemiologic study of age-related cataracts among an elderly Chinese population in Shih-Pai, Taiwan.

    PubMed

    Tsai, Su-Ying; Hsu, Wen-Ming; Cheng, Ching-Yu; Liu, Jorn-Hon; Chou, Pesus

    2003-06-01

    The purpose of this study was to determine the prevalence and risk factors for age-related cataracts in a metropolitan elderly Chinese population in Shihpai, Taipei, Taiwan. Population-based cross-sectional study. A total of 2045 subjects at least 65 years of age were invited to participate, and 1361 (66.6%) participated in the survey. An eye examination, including lens opacity grading, was conducted by ophthalmologists using the Lens Opacity Classification System III (LOCS III). A structured questionnaire was used for data collection. Interviewers also collected information on subjects' blood pressure, lifestyle (cigarette smoking and alcohol intake), medical history, and waist and hip circumferences. Subjects were defined as having age-related cataracts if there was any type of lens opacity with an LOCS III grade of more than 2 in one or both eyes. When both eyes of an individual had age-related cataracts, the more affected eye was used for analysis. Among the 1361 participants, 806 were diagnosed with age-related cataracts. The prevalence was 59.2% (95% confidence interval, 56.6%-61.8%). Women had a higher prevalence of cataracts than men (64.0% vs. 56.1%, P = 0.004). The prevalence of age-related cataracts increased with age (P = 0.001). Nuclear opacity was the most prevalent type (38.9%), followed by cortical opacity (21.9%) and posterior subcapsular opacity (9.2%). On the basis of the final logistic regression model, after controlling for all other covariates, increased age and female gender were factors that were associated with an increased risk for all types of cataracts. Besides age and gender, the most significant risk factor for nuclear cataracts was current cigarette smoking; the significant predictors for cortical cataracts were higher systolic blood pressure, a history of cigarette smoking in the past, and history of diabetes; the significant predictor for posterior subcapsular cataracts was higher systolic blood pressure. The increasing prevalence

  9. Aging and Age-Related Diseases of the Ocular Lens and Vitreous Body

    PubMed Central

    Petrash, J. Mark

    2013-01-01

    Reduced quality of life and financial burden due to visual impairment and blindness begin to increase dramatically when individuals reach the age of 40. The major causes of age-related vision loss can be traced to changes to the structure and function of the lens, one of the tissues responsible for focusing light on the retina. Age-related nuclear cataracts, which are caused by aggregation and condensation of proteins, diminish vision because they impede the transmission and focusing of light on the retina. In addition to the slow-developing age-related form, cataracts often develop rapidly as a complication of ocular surgery, such as following vitrectomy or as a consequence of vitreous gel degeneration. Posterior capsular opacification, which can develop following cataract removal, is caused by proliferation and inappropriate accumulation of lens epithelial cells on the surfaces of intraocular lenses and the posterior lens capsule. Presbyopia is a loss of accommodative amplitude and reduced ability to shift focus from far to near objects. Onset of presbyopia is associated with an increase in lens hardness and reduced ability of the lens to change shape in response to ciliary muscle contraction. Avenues of promising research that seek to delay or prevent these causes of low vision are discussed in light of our current understanding of disease pathogenesis and some challenges that must be met to achieve success. PMID:24335070

  10. TU-E-201-01: Methods for Eye Lens Dosimetry and Studies On Lens Opacities with Interventionists

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rehani, M.

    Madan M. Rehani, Massachusetts General Hospital and Harvard Medical School, Boston Methods for Eye Lens Dosimetry and Studies On Lens Opacities with Interventionalists Radiation induced cataract is a major threat among staff working in interventional suites. Nearly 16 million interventional procedures are performed annually in USA. Recent studies by the principal investigator’s group, primarily among interventional cardiologists, on behalf of the International Atomic Energy Agency, show posterior subcapsular (PSC) changes in the eye lens in 38–53% of main operators and 21–45% of support staff. These changes have potential to lead to cataract in future years, as per information from A-Bombmore » survivors. The International Commission on Radiological Protection has reduced dose limit for staff by a factor of 7.5 (from 150 mSv/y to 20 mSv/y). With increasing emphasis on radiation induced cataracts and reduction in threshold dose for eye lens, there is a need to implement strategies for estimating eye lens dose. Unfortunately eye lens dosimetry is at infancy when it comes to routine application. Various approaches are being tried namely direct measurement using active or passive dosimeters kept close to eyes, retrospective estimations and lastly correlating patient dose in interventional procedures with staff eye dose. The talk will review all approaches available and ongoing active research in this area, as well as data from surveys done in Europe on status of eye dose monitoring in interventional radiology and nuclear medicine. The talk will provide update on how good is Hp(10) against Hp(3), estimations from CTDI values, Monte Carlo based simulations and current status of eye lens dosimetry in USA and Europe. The cataract risk among patients is in CT examinations of the head. Since radiation induced cataract predominantly occurs in posterior sub-capsular (PSC) region and is thus distinguishable from age or drug related cataracts and is also preventable

  11. Lens opacities in women in Beaver Dam, Wisconsin: is there evidence of an effect of sex hormones?

    PubMed Central

    Klein, B E

    1993-01-01

    Analyses reported here suggest a protective effect of estrogen status on lens opacities, which are very common in adult Americans. Clinical trials are currently underway to assess protective effects of past menopausal estrogens on other disease. Evaluation of lenses of the participants would shed light on effects in the lens. PMID:8140704

  12. Crystalline lens paradoxes revisited: significance of age-related restructuring of the GRIN.

    PubMed

    Sheil, Conor J; Goncharov, Alexander V

    2017-09-01

    The accommodating volume-constant age-dependent optical (AVOCADO) model of the crystalline lens is used to explore the age-related changes in ocular power and spherical aberration. The additional parameter m in the GRIN lens model allows decoupling of the axial and radial GRIN profiles, and is used to stabilise the age-related change in ocular power. Data for age-related changes in ocular geometry and lens parameter P in the axial GRIN profile were taken from published experimental data. In our age-dependent eye model, the ocular refractive power shows behaviour similar to the previously unexplained "lens paradox". Furthermore, ocular spherical aberration agrees with the data average, in contrast to the proposed "spherical aberration paradox". The additional flexibility afforded by parameter m , which controls the ratio of the axial and radial GRIN profile exponents, has allowed us to study the restructuring of the lens GRIN medium with age, resulting in a new interpretation of the origin of the power and spherical aberration paradoxes. Our findings also contradict the conceptual idea that the ageing eye is similar to the accommodating eye.

  13. Lens Opacity and Hydrogen Sulfide in a New Zealand Geothermal Area.

    PubMed

    Bates, Michael N; Bailey, Ian L; DiMartino, Robert B; Pope, Karl; Crane, Julian; Garrett, Nick

    2017-04-01

    Hydrogen sulfide (H2S) is a highly toxic gas with well-established, acute irritation effects on the eye. The population of Rotorua, New Zealand, sited on an active geothermal field, has some of the highest ambient H2S exposures in the world. Evidence from ecological studies in Rotorua has suggested that H2S is associated with cataract. The purpose of the present study was, using more detailed exposure characterization, clinical examinations, and anterior eye photography, to more directly investigate this previously reported association. Enrolled were 1637 adults, ages 18 to 65, from a comprehensive Rotorua primary care medical register. Patients underwent a comprehensive ophthalmic examination, including pupillary dilation and lens photography to capture evidence of any nuclear opacity, nuclear color, and cortical and posterior subcapsular opacity. Photographs were scored for all four outcomes on the LOCS III scale with decimalized interpolation between the exemplars. H2S exposure for up to the last 30 years was estimated based on networks of passive samplers set out across Rotorua and knowledge of residential, workplace, and school locations over the 30 years. Data analysis using linear and logistic regression examined associations between the degree of opacification and nuclear color or cataract (defined as a LOCS III score ≥2.0) in relation to H2S exposure. No associations were found between estimated H2S exposures and any of the four ophthalmic outcome measures. Overall, results were generally reassuring. They provided no evidence that H2S exposure at the levels found in Rotorua is associated with cataract. The previously found association between cataract and H2S exposure in the Rotorua population seems likely to be attributable to the limitations of the ecological study design. These results cannot rule out the possibility of an association with cataract at higher levels of H2S exposure.

  14. Different alpha crystallin expression in human age-related and congenital cataract lens epithelium.

    PubMed

    Yang, Jing; Zhou, Sheng; Guo, Minfei; Li, Yuting; Gu, Jianjun

    2016-05-28

    The purpose of this study was to investigate the different expressions of αA-crystallin and αB-crystallin in human lens epithelium of age-related and congenital cataracts. The central part of the human anterior lens capsule approximately 5 mm in diameter together with the adhering epithelial cells, were harvested and processed within 6 hours after cataract surgery from age-related and congenital cataract patients or from normal eyes of fresh cadavers. The mRNA and soluble protein levels of αA-crystallin and αB-crystallin in the human lens epithelium were detected by real-time PCR and western blots, respectively. The mRNA and soluble protein expressions of αA-crystallin and αB-crystallin in the lens epithelium were both reduced in age-related and congenital cataract groups when compared with the normal control group. However, the degree of α-crystallin loss in the lens epithelium was highly correlated with different cataract types. The α-crystallin expression of the lens epithelium was greatly reduced in the congenital cataract group but only moderately decreased in the age-related cataract group. The reduction of αA-crystallin soluble protein levels in the congenital cataract group was approximately 2.4 fold decrease compared with that of the age-related cataract group, while an mRNA fold change of 1.67 decrease was observed for the age-related cataract group. Similarly, the reduction of soluble protein levels of αB-crystallin in the congenital cataract group was approximately a 1.57 fold change compared with that of the age-related cataract group. A 1.75 fold change for mRNA levels compared with that of the age-related cataract group was observed. The results suggest that the differential loss of α-crystallin in the human lens epithelium could be associated with the different mechanisms of cataractogenesis in age-related versus congenital cataracts, subsequently resulting in different clinical presentations.

  15. Crystalline lens power and refractive error.

    PubMed

    Iribarren, Rafael; Morgan, Ian G; Nangia, Vinay; Jonas, Jost B

    2012-02-01

    To study the relationships between the refractive power of the crystalline lens, overall refractive error of the eye, and degree of nuclear cataract. All phakic participants of the population-based Central India Eye and Medical Study with an age of 50+ years were included. Calculation of the refractive lens power was based on distance noncycloplegic refractive error, corneal refractive power, anterior chamber depth, lens thickness, and axial length according to Bennett's formula. The study included 1885 subjects. Mean refractive lens power was 25.5 ± 3.0 D (range, 13.9-36.6). After adjustment for age and sex, the standardized correlation coefficients (β) of the association with the ocular refractive error were highest for crystalline lens power (β = -0.41; P < 0.001) and nuclear lens opacity grade (β = -0.42; P < 0.001), followed by axial length (β = -0.35; P < 0.001). They were lowest for corneal refractive power (β = -0.08; P = 0.001) and anterior chamber depth (β = -0.05; P = 0.04). In multivariate analysis, refractive error was significantly (P < 0.001) associated with shorter axial length (β = -1.26), lower refractive lens power (β = -0.95), lower corneal refractive power (β = -0.76), higher lens thickness (β = 0.30), deeper anterior chamber (β = 0.28), and less marked nuclear lens opacity (β = -0.05). Lens thickness was significantly lower in eyes with greater nuclear opacity. Variations in refractive error in adults aged 50+ years were mostly influenced by variations in axial length and in crystalline lens refractive power, followed by variations in corneal refractive power, and, to a minor degree, by variations in lens thickness and anterior chamber depth.

  16. Effect of Age-Related Human Lens Sutures Growth on Its Fluid Dynamics.

    PubMed

    Wu, Ho-Ting D; Howse, Louisa A; Vaghefi, Ehsan

    2017-12-01

    Age-related nuclear cataract is the opacification of the clear ocular lens due to oxidative damage as we age, and is the leading cause of blindness in the world. A lack of antioxidant supply to the core of ever-growing ocular lens could contribute to the cause of this condition. In this project, a computational model was developed to study the sutural fluid inflow of the aging human lens. Three different SOLIDWORKS computational fluid dynamics models of the human lens (7 years old; 28 years old; 46 years old) were created, based on available literature data. The fluid dynamics of the lens sutures were modelled using the Stokes flow equations, combined with realistic physiological boundary conditions and embedded in COMSOL Multiphysics. The flow rate, volume, and flow rate per volume of fluid entering the aging lens were examined, and all increased over the 40 years modelled. However, while the volume of the lens grew by ∼300% and the flow rate increased by ∼400%, the flow rate per volume increased only by very moderate ∼38%. Here, sutural information from humans of 7 to 46 years of age was obtained. In this modelled age range, an increase of flow rate per volume was observed, albeit at very slow rate. We hypothesize that with even further increasing age (60+ years old), the lens volume growth would outpace its flow rate increases, which would eventually lead to malnutrition of the lens nucleus and onset of cataracts.

  17. Age-Related Changes in Centripetal Ciliary Body Movement Relative to Centripetal Lens Movement in Monkeys

    PubMed Central

    Croft, Mary Ann; McDonald, Jared P.; Nadkarni, Nivedita V.; Lin, Ting-Li; Kaufman, Paul L.

    2009-01-01

    The goal was to determine the age-related changes in accommodative movements of the lens and ciliary body in rhesus monkeys. Varying levels of accommodation were stimulated via the Edinger-Westphal (E-W) nucleus in 26 rhesus monkeys, aged 6-27 years, and the refractive changes were measured by coincidence refractometry. Centripetal ciliary process (CP) and lens movements were measured by computerized image analysis of goniovideographic images. Ultrasound biomicroscopy (UBM) at 50 MHz was used to visualize and measure accommodative forward movements of the ciliary body in relation to age, accommodative amplitude, and centripetal CP and lens movements. At ∼3 diopters of accommodation, the amount of centripetal lens movement required did not significantly change with age (p=0.10; n=18 monkeys); however, the amount of centripetal CP movement required significantly increased with age (p=0.01; n=18 monkeys), while the amount of forward ciliary body movement significantly decreased with age (p=0.007; n=11 monkeys). In the middle-aged animals (12-16.5 years), a greater amount of centripetal CP movement was required to induce a given level of lens movement and thereby a given level of accommodation (p=0.01), compared to the young animals (6-10 yrs). Collectively, the data suggests that, with age, the accommodative system may be attempting to compensate for the loss of forward ciliary body movement by increasing the amount of centripetal CP movement. This, in turn, would allow enough zonular relaxation to achieve the magnitude of centripetal lens movement necessary for a given amplitude of accommodation. PMID:19635475

  18. Three-Dimensional Cataract Crystalline Lens Imaging With Swept-Source Optical Coherence Tomography.

    PubMed

    de Castro, Alberto; Benito, Antonio; Manzanera, Silvestre; Mompeán, Juan; Cañizares, Belén; Martínez, David; Marín, Jose María; Grulkowski, Ireneusz; Artal, Pablo

    2018-02-01

    To image, describe, and characterize different features visible in the crystalline lens of older adults with and without cataract when imaged three-dimensionally with a swept-source optical coherence tomography (SS-OCT) system. We used a new SS-OCT laboratory prototype designed to enhance the visualization of the crystalline lens and imaged the entire anterior segment of both eyes in two groups of participants: patients scheduled to undergo cataract surgery, n = 17, age range 36 to 91 years old, and volunteers without visual complains, n = 14, age range 20 to 81 years old. Pre-cataract surgery patients were also clinically graded according to the Lens Opacification Classification System III. The three-dimensional location and shape of the visible opacities were compared with the clinical grading. Hypo- and hyperreflective features were visible in the lens of all pre-cataract surgery patients and in some of the older adults in the volunteer group. When the clinical examination revealed cortical or subcapsular cataracts, hyperreflective features were visible either in the cortex parallel to the surfaces of the lens or in the posterior pole. Other type of opacities that appeared as hyporeflective localized features were identified in the cortex of the lens. The OCT signal in the nucleus of the crystalline lens correlated with the nuclear cataract clinical grade. A dedicated OCT is a useful tool to study in vivo the subtle opacities in the cataractous crystalline lens, revealing its position and size three-dimensionally. The use of these images allows obtaining more detailed information on the age-related changes leading to cataract.

  19. Lens Opacity and Hydrogen Sulfide in a New Zealand Geothermal Area

    PubMed Central

    Bates, Michael N.; Bailey, Ian L.; DiMartino, Robert B.; Pope, Karl; Crane, Julian; Garrett, Nick

    2016-01-01

    Purpose Hydrogen sulfide (H2S) is a highly toxic gas with well-established, acute irritation effects on the eye. The population of Rotorua, New Zealand, sited on an active geothermal field has some of the highest ambient H2S exposures in the world. Evidence from ecological studies in Rotorua has suggested that H2S is associated with cataract. The purpose of the present study was, using more detailed exposure characterization, clinical examinations and anterior eye photography, to more directly investigate this previously reported association. Methods Enrolled were 1637 adults, ages 18–65, from a comprehensive Rotorua primary care medical register. Patients underwent a comprehensive ophthalmic examination, including pupillary dilation and lens photography to capture evidence of any nuclear opacity, nuclear color, and cortical and posterior subcapsular opacity. Photographs were scored for all four outcomes on the LOCS III scale with decimalized interpolation between the exemplars. H2S exposure for up to the last 30 years was estimated based on networks of passive samplers set out across Rotorua and knowledge of residential, workplace and school locations over the 30 years. Data analysis using linear and logistic regression examined associations between the degree of opacification and nuclear color or cataract (defined as a LOCS III score ≥ 2.0) in relation to H2S exposure. Results No associations were found between estimated H2S exposures and any of the four ophthalmic outcome measures. Conclusions Overall, results were generally reassuring. They provided no evidence that H2S exposure at the levels found in Rotorua is associated with cataract. The previously found association between cataract and H2S exposure in the Rotorua population seems likely to be attributable to the limitations of the ecological study design. These results cannot rule out the possibility of an association with cataract at higher levels of H2S exposure. PMID:28182590

  20. Radiation-induced eye lens changes and risk for cataract in interventional cardiology.

    PubMed

    Ciraj-Bjelac, O; Rehani, M; Minamoto, A; Sim, K H; Liew, H B; Vano, E

    2012-01-01

    Recent studies have reported a significant increase in eye lens opacities among staff in the cardiac catheterization laboratory but indicated further studies are needed to confirm the findings. To evaluate the prevalence of opacities in eyes of cardiologists, radiographers and nurses working in interventional cardiology. The eyes of 52 staff in interventional cardiology facilities and 34 age- and sex-matched unexposed controls were screened in a cardiology conference held in Kuala Lumpur by dilated slit-lamp examination, and posterior lens changes were graded. Individual cumulative lens X-ray exposures were calculated from responses to a questionnaire in terms of workload and working practice. The prevalence of posterior lens opacities among interventional cardiologists was 53%, while in nurses and radiographers it was 45%. Corresponding relative risks were 2.6 (95% CI: 1.2-5.4) and 2.2 (95% CI: 0.98-4.9), for interventional cardiologists and support staff, respectively. This study confirms a statistically significant increase in radiation-associated posterior lens changes in the eyes of interventional cardiology staff. Copyright © 2012 S. Karger AG, Basel.

  1. Age-related changes in spectral transmittance of the human crystalline lens in situ.

    PubMed

    Sakanishi, Yoshihito; Awano, Masakazu; Mizota, Atsushi; Tanaka, Minoru; Murakami, Akira; Ohnuma, Kazuhiko

    2012-01-01

    It was the aim of this study to measure spectral transmission of the human crystalline lens in situ. The crystalline lens was illuminated by one of four light-emitting diodes of different colors. The relative spectral transmittance of the human crystalline lens was measured with the Purkinje-Sanson mirror images over a wide range of ages. The study evaluated 36 crystalline lenses of 28 subjects aged 21-76 years. There was a significant correlation between the age and spectral transmittance for blue light. Spectral transmittance of the crystalline lens in situ could be measured with Purkinje-Sanson mirror images. Copyright © 2012 S. Karger AG, Basel.

  2. The lens and cataracts.

    PubMed

    Matthews, Andrew G

    2004-08-01

    It is conservatively estimated that some form of lens opacity is present in 5% to 7% of horses with otherwise clinically normal eyes.These opacities can range from small epicapsular remnants of the fetal vasculature to dense and extensive cataract. A cataract is defined technically as any opacity or alteration in the optical homogeneity of the lens involving one or more of the following: anterior epithelium, capsule, cortex, or nucleus. In the horse, cataracts rarely involve the entire lens structure (ie, complete cataracts) and are more usually localized to one anatomic landmark or sector of the lens. Complete cataracts are invariably associated with overt and significant visual disability. Focal or incomplete cataracts alone seldom cause any apparent visual dysfunction in affected horses,however.

  3. In Vivo Brillouin Analysis of the Aging Crystalline Lens

    PubMed Central

    Besner, Sebastien; Scarcelli, Giuliano; Pineda, Roberto; Yun, Seok-Hyun

    2016-01-01

    Purpose To analyze the age dependence of the longitudinal modulus of the crystalline lens in vivo using Brillouin scattering data in healthy subjects. Methods Brillouin scans were performed along the crystalline lens in 56 eyes from 30 healthy subjects aged from 19 to 63 years. Longitudinal elastic modulus was acquired along the sagittal axis of the lens with a transverse and axial resolution of 4 and 60 μm, respectively. The relative lens stiffness was computed, and correlations with age were analyzed. Results Brillouin axial profiles revealed nonuniform longitudinal modulus within the lens, increasing from a softer periphery toward a stiffer central plateau at all ages. The longitudinal modulus at the central plateau showed no age dependence in a range of 19 to 45 years and a slight decrease with age from 45 to 63 years. A significant intersubject variability was observed in an age-matched analysis. Importantly, the extent of the central stiff plateau region increased steadily over age from 19 to 63 years. The slope of change in Brillouin modulus in the peripheral regions were nearly age-invariant. Conclusions The adult human lens showed no measurable age-related increase in the peak longitudinal modulus. The expansion of the stiff central region of the lens is likely to be the major contributing factor to age-related lens stiffening. Brillouin microscopy may be useful in characterizing the crystalline lens for the optimization of surgical or pharmacological treatments aimed at restoring accommodative power. PMID:27699407

  4. In Vivo Brillouin Analysis of the Aging Crystalline Lens.

    PubMed

    Besner, Sebastien; Scarcelli, Giuliano; Pineda, Roberto; Yun, Seok-Hyun

    2016-10-01

    To analyze the age dependence of the longitudinal modulus of the crystalline lens in vivo using Brillouin scattering data in healthy subjects. Brillouin scans were performed along the crystalline lens in 56 eyes from 30 healthy subjects aged from 19 to 63 years. Longitudinal elastic modulus was acquired along the sagittal axis of the lens with a transverse and axial resolution of 4 and 60 μm, respectively. The relative lens stiffness was computed, and correlations with age were analyzed. Brillouin axial profiles revealed nonuniform longitudinal modulus within the lens, increasing from a softer periphery toward a stiffer central plateau at all ages. The longitudinal modulus at the central plateau showed no age dependence in a range of 19 to 45 years and a slight decrease with age from 45 to 63 years. A significant intersubject variability was observed in an age-matched analysis. Importantly, the extent of the central stiff plateau region increased steadily over age from 19 to 63 years. The slope of change in Brillouin modulus in the peripheral regions were nearly age-invariant. The adult human lens showed no measurable age-related increase in the peak longitudinal modulus. The expansion of the stiff central region of the lens is likely to be the major contributing factor to age-related lens stiffening. Brillouin microscopy may be useful in characterizing the crystalline lens for the optimization of surgical or pharmacological treatments aimed at restoring accommodative power.

  5. NASA study of cataract in astronauts (NASCA). Report 1: Cross-sectional study of the relationship of exposure to space radiation and risk of lens opacity.

    PubMed

    Chylack, Leo T; Peterson, Leif E; Feiveson, Alan H; Wear, Mary L; Manuel, F Keith; Tung, William H; Hardy, Dale S; Marak, Lisa J; Cucinotta, Francis A

    2009-07-01

    The NASA Study of Cataract in Astronauts (NASCA) is a 5-year longitudinal study of the effect of space radiation exposure on the severity/progression of nuclear, cortical and posterior subcapsular (PSC) lens opacities. Here we report on baseline data that will be used over the course of the longitudinal study. Participants include 171 consenting astronauts who flew at least one mission in space and a comparison group made up of three components: (a) 53 astronauts who had not flown in space, (b) 95 military aircrew personnel, and (c) 99 non-aircrew ground-based comparison subjects. Continuous measures of nuclear, cortical and PSC lens opacities were derived from Nidek EAS 1000 digitized images. Age, demographics, general health, nutritional intake and solar ocular exposure were measured at baseline. Astronauts who flew at least one mission were matched to comparison subjects using propensity scores based on demographic characteristics and medical history stratified by gender and smoking (ever/never). The cross-sectional data for matched subjects were analyzed by fitting customized non-normal regression models to examine the effect of space radiation on each measure of opacity. The variability and median of cortical cataracts were significantly higher for exposed astronauts than for nonexposed astronauts and comparison subjects with similar ages (P=0.015). Galactic cosmic space radiation (GCR) may be linked to increased PSC area (P=0.056) and the number of PSC centers (P=0.095). Within the astronaut group, PSC size was greater in subjects with higher space radiation doses (P=0.016). No association was found between space radiation and nuclear cataracts. Cross-sectional data analysis revealed a small deleterious effect of space radiation for cortical cataracts and possibly for PSC cataracts. These results suggest increased cataract risks at smaller radiation doses than have been reported previously.

  6. Localization of low molecular weight crystallin peptides in the aging human lens using a MALDI mass spectrometry imaging approach.

    PubMed

    Su, Shih-Ping; McArthur, Jason D; Andrew Aquilina, J

    2010-07-01

    Low molecular weight (LMW) peptides, derived from the breakdown of the major eye lens proteins, the crystallins, accumulate in the human lens with age. These LMW peptides are associated with age-related lens opacity and cataract, with some shown to inhibit the chaperone activity of alpha-crystallin. However, the mechanism(s) giving rise to the production of these peptides, as well as their distribution within the lens, are not well understood. In this study, we have mapped the distribution of these crystallin-derived peptides present in human lenses of different ages using matrix-assisted laser desorption/ionization-imaging mass spectrometry (MALDI-IMS). Our data showed that most of these LMW peptides emerge in the lens at early middle-age, with peptides greater than 1778 Da in mass being confined to the water insoluble fractions, and to a lesser extent the water soluble fractions of older lenses. MALDI-IMS analyses showed that four peptides, derived from alphaA-, alphaB- and gammaS-crystallins, were confined to the lens nuclear fibre cells upon emergence during early middle-age, but were present in both the cortex and nucleus of old lenses. In contrast, another major peptide, derived from the C-terminal breakdown of betaA3-crystallin, was present in the cortical and nuclear regions of both young and old lenses. A comparison between age-matched cataractous and non-cataractous lenses showed no distinct differences in LMW peptide profiles, indicating that although cataract may be a potential consequence caused by the emergence of these peptides, it does not contribute directly to the peptide-generating process. Crown Copyright 2010. Published by Elsevier Ltd. All rights reserved.

  7. The eye lens: age-related trends and individual variations in refractive index and shape parameters.

    PubMed

    Pierscionek, Barbara; Bahrami, Mehdi; Hoshino, Masato; Uesugi, Kentaro; Regini, Justyn; Yagi, Naoto

    2015-10-13

    The eye lens grows throughout life by cell accrual on its surface and can change shape to adjust the focussing power of the eye. Varying concentrations of proteins in successive cell layers create a refractive index gradient. The continued growth of the lens and age-related changes in proteins render it less able to alter shape with loss of capacity by the end of the sixth decade of life. Growth and protein ageing alter the refractive index but as accurate measurement of this parameter is difficult, the nature of such alterations remains uncertain. The most accurate method to date for measuring refractive index in intact lenses has been developed at the SPring-8 synchrotron. The technique, based on Talbot interferometry, has an X-ray source and was used to measure refractive index in sixty-six human lenses, aged from 16 to 91 years. Height and width were measured for forty-five lenses. Refractive index contours show decentration in some older lenses but individual variations mask age-related trends. Refractive index profiles along the optic axis have relatively flat central sections with distinct micro-fluctuations and a steep gradient in the cortex but do not exhibit an age-related trend. The refractive index profiles in the equatorial aspect show statistical significance with age, particularly for lenses below the age of sixty that had capacity to alter shape in vivo. The maximum refractive index in the lens centre decreases slightly with age with considerable scatter in the data and there are age-related variations in sagittal thickness and equatorial height.

  8. The eye lens: age-related trends and individual variations in refractive index and shape parameters

    PubMed Central

    Pierscionek, Barbara; Bahrami, Mehdi; Hoshino, Masato; Uesugi, Kentaro; Regini, Justyn; Yagi, Naoto

    2015-01-01

    The eye lens grows throughout life by cell accrual on its surface and can change shape to adjust the focussing power of the eye. Varying concentrations of proteins in successive cell layers create a refractive index gradient. The continued growth of the lens and age-related changes in proteins render it less able to alter shape with loss of capacity by the end of the sixth decade of life. Growth and protein ageing alter the refractive index but as accurate measurement of this parameter is difficult, the nature of such alterations remains uncertain. The most accurate method to date for measuring refractive index in intact lenses has been developed at the SPring-8 synchrotron. The technique, based on Talbot interferometry, has an X-ray source and was used to measure refractive index in sixty-six human lenses, aged from 16 to 91 years. Height and width were measured for forty-five lenses. Refractive index contours show decentration in some older lenses but individual variations mask age-related trends. Refractive index profiles along the optic axis have relatively flat central sections with distinct micro-fluctuations and a steep gradient in the cortex but do not exhibit an age-related trend. The refractive index profiles in the equatorial aspect show statistical significance with age, particularly for lenses below the age of sixty that had capacity to alter shape in vivo. The maximum refractive index in the lens centre decreases slightly with age with considerable scatter in the data and there are age-related variations in sagittal thickness and equatorial height. PMID:26416418

  9. NASCA Report 2: Longitudinal Study of Relationship of Exposure to Space Radiation and Risk of Lens Opacity

    NASA Technical Reports Server (NTRS)

    Chylack, Leon T., Jr.; Peterson, Leif E.; Feiveson, Alan H.; Tung, William H.; Wear, Mary L.; Marak, Lisa J.; Hardy, Dale S.; Cucinotta, Francis A.

    2011-01-01

    The NASA Study of Cataract in Astronauts (NASCA) was a five-year longitudinal study of the effect of space radiation exposure on the severity/progression of nuclear (N), cortical (C), and posterior subcapsular (PSC) lens opacities. It began in 2003 and was completed in December, 2009. Participants included 171 consenting astronauts who flew at least one mission in space, and comparison subjects consisted of three groups, a) 53 astronauts who had not flown in space, b) 95 military aircrew personnel, and c) 99 non-aircrew, ground-based subjects.

  10. Eye Lens Radiation Exposure in Greek Interventional Cardiology Article.

    PubMed

    Thrapsanioti, Zoi; Askounis, Panagiotis; Datseris, Ioannis; Diamanti, Ramza Anastasia; Papathanasiou, Miltiadis; Carinou, Eleftheria

    2017-07-01

    The lens of the eye is one of the radiosensitive tissues of the human body; if exposed to ionizing radiation can develop radiation-induced cataract at early ages. This study was held in Greece and included 44 Interventional Cardiologists (ICs) and an unexposed to radiation control group of 22 persons. Of the note, 26 ICs and the unexposed individuals underwent special eye examinations. The detected lens opacities were classified according to LOCS III protocol. Additionally, the lens doses of the ICs were measured using eye lens dosemeters. The mean dose to the lenses of the ICs per month was 0.83 ± 0.59 mSv for the left and 0.35 ± 0.38 mSv for the right eye, while the annual doses ranged between 0.7 and 11 mSv. Regarding the lens opacities, the two groups did not differ significantly in the prevalence of either nuclear or cortical lens opacities, whereas four ICs were detected with early stage subcapsular sclerosis. Though no statistically difference was observed in the cohort, the measured doses indicate that the eye doses received from the ICs can be significant. To minimize the radiation-induced risk at the eye lenses, the use of protective equipment and appropriate training on this issue is highly recommended. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  11. Clinical Detection of Pre-Cataractous Lens Protein Changes using Dynamic Light Scattering

    PubMed Central

    Datiles, Manuel B.; Ansari, Rafat R.; Suh, Kwang I.; Vitale, Susan; Reed, George F.; Zigler, J. Samuel; Ferris., Frederick L.

    2008-01-01

    Purpose To use Dynamic Light Scattering (DLS) to clinically assess early pre-cataractous lens protein changes. Methods We performed a cross sectional study in 380 eyes of 235 subjects aged 7–86 years with AREDS clinical lens nuclear grades ranging from 0–3.8. A DLS device was used to assess α-crystallin, a molecular chaperone protein shown to bind other damaged lens proteins, preventing their aggregation. The outcome measure was the α-crystallin index (ACI), a measure of unbound α-crystallin in each lens. The association of ACI with increasing nuclear opacity and aging was determined. Results There was a significant decrease in ACI associated with increasing grades of lens nuclear opacity (p<0.0001). There are significant losses of α-crystallin even in clinically clear lenses associated with aging (p<0.0001). The standard error of measurement was 3%. Conclusions DLS clinically detects loss of α-crystallin proteins even in clinically clear lenses. ACI measurements may be useful in identifying patients at high risk for developing cataract, and as an outcome variable in clinical lens studies. Clinical Relevance Our studies suggest that the ACI may be a useful measure of the protective α-crystallin molecular chaperone reserve present in a lens, analogous to creatinine clearance in estimating renal function reserve. PMID:19064850

  12. Intrinsically photosensitive retinal ganglion cell function in relation to age: A pupillometric study in humans with special reference to the age-related optic properties of the lens

    PubMed Central

    2012-01-01

    Background The activity of melanopsin containing intrinsically photosensitive ganglion retinal cells (ipRGC) can be assessed by a means of pupil responses to bright blue (appr.480 nm) light. Due to age related factors in the eye, particularly, structural changes of the lens, less light reaches retina. The aim of this study was to examine how age and in vivo measured lens transmission of blue light might affect pupil light responses, in particular, mediated by the ipRGC. Methods Consensual pupil responses were explored in 44 healthy subjects aged between 26 and 68 years. A pupil response was recorded to a continuous 20 s light stimulus of 660 nm (red) or 470 nm (blue) both at 300 cd/m2 intensity (14.9 and 14.8 log photons/cm2/s, respectively). Additional recordings were performed using four 470 nm stimulus intensities of 3, 30, 100 and 300 cd/m2. The baseline pupil size was measured in darkness and results were adjusted for the baseline pupil and gender. The main outcome parameters were maximal and sustained pupil contraction amplitudes and the postillumination response assessed as area under the curve (AUC) over two time-windows: early (0–10 s after light termination) and late (10–30 s after light termination). Lens transmission was measured with an ocular fluorometer. Results The sustained pupil contraction and the early poststimulus AUC correlated positively with age (p = 0.02, p = 0.0014, respectively) for the blue light stimulus condition only. The maximal pupil contraction amplitude did not correlate to age either for bright blue or red light stimulus conditions. Lens transmission decreased linearly with age (p < 0.0001). The pupil response was stable or increased with decreasing transmission, though only significantly for the early poststimulus AUC to 300 cd/m2 light (p = 0.02). Conclusions Age did not reduce, but rather enhance pupil responses mediated by ipRGC. The age related decrease of blue light transmission led

  13. Macular pigment and lens optical density measurements-evaluating a flicker machine with novel features

    NASA Astrophysics Data System (ADS)

    Mukherjee, Anirbaan

    Age related macular degeneration (AMD) is one of the leading causes of blindness amongst the elderly. Macular pigment (MP) in the retina has been established to protect individuals against AMD. Improving levels of MP by diet or supplements is the constant quest of clinical practitioners and researchers, thus necessitating development of instruments capable of repeatable and reliable MP measurement. Cataract, a consequence of the rising opacity levels of the lens with age is one of the other major causes of blindness in the world. Mapcatsf, a LED-based microprocessor-controlled heterochromatic flicker photometer (HFP) using photopic vision is capable of measuring the levels of MP and the opacity of the lens in terms of optical density. Test-retest measurements conducted on 83 subjects were analyzed for repeatability in macular pigment optical density (MPOD) measurements. Reliability of the lens optical density (LOD) measurements were tested and compared with those obtained at absolute scotopic thresholds for 25 individuals. A supplement study with 32 individuals both in the young (50) age groups for 6 months further established Mapcatsf's capacity to monitor changing levels of MP in individuals. As an overall outcome, high levels of repeatability and reliability were obtained in MPOD and LOD measurements establishing Mapcatsf as an instrument for use in clinical settings in the future.

  14. ACCOMMODATIVE MOVEMENTS OF THE LENS/CAPSULE AND THE STRAND THAT EXTENDS BETWEEN THE POSTERIOR VITREOUS ZONULE INSERTION ZONE & THE LENS EQUATOR, IN RELATION TO THE VITREOUS FACE AND AGING

    PubMed Central

    CROFT, MARY ANN; HEATLEY, GREGG; MCDONALD, JARED P.; KATZ, ALEXANDER; KAUFMAN, PAUL L.

    2016-01-01

    Purpose To elucidate the dynamic accommodative movements of the lens capsule, posterior lens and the strand that attaches to the posterior vitreous zonule insertion zone and posterior lens equator (PVZ INS-LE), and their age-related changes. Methods Twelve human subjects (ages 19–65 years) and twelve rhesus monkeys (ages 6–27 years) were studied. Accommodation was induced pharmacologically (humans) or by central electrical stimulation (monkeys). Ultrasound biomicroscopy was used to image intraocular structures in both species. Surgical procedures and contrast agents were utilized in the monkey eyes to elucidate function and allow visualization of the intraocular accommodative structures. Results Human: The posterior pole of the lens moves posteriorly during accommodation in proportion to accommodative amplitude and ciliary muscle movement. Monkey: Similar accommodative movements of the posterior lens pole were seen in the monkey eyes. Following extracapsular lens extraction (ECLE), the central capsule bows backward during accommodation in proportion to accommodative amplitude and ciliary muscle movement, while the peripheral capsule moves forward. During accommodation the ciliary muscle moved forward by ~1.0 mm, pulling forward the vitreous zonule and the PVZ INS-LE structure. During the accommodative response the PVZ INS-LE structure moved forward when the lens was intact and when the lens substance and capsule were removed. In both the monkey and the human eyes these movements declined with age. Conclusions The accommodative shape change of the central capsule may be due to the elastic properties of the capsule itself. For these capsule/lens accommodative posterior movements to occur, the vitreous face must either allow for it or facilitate it. The PVZ INS-LE structure may act as a “strut” to the posterior lens equator (pushing the lens equator forward) and thereby facilitate accommodative forward lens equator movement and lens thickening. The age-related

  15. Age and Smoking Related Changes in Metal Ion Levels in Human Lens: Implications for Cataract Formation

    PubMed Central

    Langford-Smith, Alex; Tilakaratna, Viranga; Lythgoe, Paul R.; Clark, Simon J.; Bishop, Paul N.; Day, Anthony J.

    2016-01-01

    Age-related cataract formation is the primary cause of blindness worldwide and although treatable by surgical removal of the lens the majority of sufferers have neither the finances nor access to the medical facilities required. Therefore, a better understanding of the pathogenesis of cataract may identify new therapeutic targets to prevent or slow its progression. Cataract incidence is strongly correlated with age and cigarette smoking, factors that are often associated with accumulation of metal ions in other tissues. Therefore this study evaluated the age-related changes in 14 metal ions in 32 post mortem human lenses without known cataract from donors of 11 to 82 years of age by inductively coupled plasma mass spectrometry; smoking-related changes in 10 smokers verses 14 non-smokers were also analysed. A significant age-related increase in selenium and decrease in copper ions was observed for the first time in the lens tissue, where cadmium ion levels were also increased as has been seen previously. Aluminium and vanadium ions were found to be increased in smokers compared to non-smokers (an analysis that has only been carried out before in lenses with cataract). These changes in metal ions, i.e. that occur as a consequence of normal ageing and of smoking, could contribute to cataract formation via induction of oxidative stress pathways, modulation of extracellular matrix structure/function and cellular toxicity. Thus, this study has identified novel changes in metal ions in human lens that could potentially drive the pathology of cataract formation. PMID:26794210

  16. Role of αA-crystallin-derived αA66-80 peptide in guinea pig lens crystallin aggregation and insolubilization

    PubMed Central

    Raju, Murugesan; Mooney, Brian P.; Thakkar, Kavi M.; Giblin, Frank J.; Schey, Kevin L.; Sharma, K. Krishna

    2015-01-01

    Earlier we reported that low molecular weight (LMW) peptides accumulate in aging human lens tissue and that among the LMW peptides, the chaperone inhibitor peptide αA66-80, derived from α-crystallin protein, is one of the predominant peptides. We showed that in vitro αA66-80 induces protein aggregation. The current study was undertaken to determine whether LMW peptides are also present in guinea pig lens tissue subjected to hyperbaric oxygen (HBO) in vivo. The nuclear opacity induced by HBO in guinea pig lens is the closest animal model for studying age-related cataract formation in humans. A LMW peptide profile by mass spectrometry showed the presence of an increased amount of LMW peptides in HBO-treated guinea pig lenses compared to age-matched controls. Interestingly, the mass spectrometric data also showed that the chaperone inhibitor peptide αA66-80 accumulates in HBO-treated guinea pig lens. Following incubation of synthetic chaperone inhibitor peptide αA66-80 with α-crystallin from guinea pig lens extracts, we observed a decreased ability of α-crystallin to inhibit the amorphous aggregation of the target protein alcohol dehydrogenase and the formation of large light scattering aggregates, similar to those we have observed with human α-crystallin and αA66-80 peptide. Further, time-lapse recordings showed that a preformed complex of α-crystallin and αA66-80 attracted additional crystallin molecules to form even larger aggregates. These results demonstrate that LMW peptide–mediated cataract development in aged human lens and in HBO-induced lens opacity in the guinea pig may have common molecular pathways. PMID:25639202

  17. Role of αA-crystallin-derived αA66-80 peptide in guinea pig lens crystallin aggregation and insolubilization.

    PubMed

    Raju, Murugesan; Mooney, Brian P; Thakkar, Kavi M; Giblin, Frank J; Schey, Kevin L; Sharma, K Krishna

    2015-03-01

    Earlier we reported that low molecular weight (LMW) peptides accumulate in aging human lens tissue and that among the LMW peptides, the chaperone inhibitor peptide αA66-80, derived from α-crystallin protein, is one of the predominant peptides. We showed that in vitro αA66-80 induces protein aggregation. The current study was undertaken to determine whether LMW peptides are also present in guinea pig lens tissue subjected to hyperbaric oxygen (HBO) in vivo. The nuclear opacity induced by HBO in guinea pig lens is the closest animal model for studying age-related cataract formation in humans. A LMW peptide profile by mass spectrometry showed the presence of an increased amount of LMW peptides in HBO-treated guinea pig lenses compared to age-matched controls. Interestingly, the mass spectrometric data also showed that the chaperone inhibitor peptide αA66-80 accumulates in HBO-treated guinea pig lens. Following incubation of synthetic chaperone inhibitor peptide αA66-80 with α-crystallin from guinea pig lens extracts, we observed a decreased ability of α-crystallin to inhibit the amorphous aggregation of the target protein alcohol dehydrogenase and the formation of large light scattering aggregates, similar to those we have observed with human α-crystallin and αA66-80 peptide. Further, time-lapse recordings showed that a preformed complex of α-crystallin and αA66-80 attracted additional crystallin molecules to form even larger aggregates. These results demonstrate that LMW peptide-mediated cataract development in aged human lens and in HBO-induced lens opacity in the guinea pig may have common molecular pathways. Copyright © 2015 Elsevier Ltd. All rights reserved.

  18. Biomass Stoves and Lens Opacity and Cataract in Nepalese Women

    PubMed Central

    Pokhrel, Amod K.; Bates, Michael N.; Shrestha, Sachet P.; Bailey, Ian L.; DiMartino, Robert B.; Smith, Kirk R.; Joshi, N. D.

    2014-01-01

    Purpose Cataract is the most prevalent cause of blindness in Nepal. Several epidemiologic studies have associated cataracts with use of biomass cookstoves. These studies, however, have had limitations, including potential control selection bias and limited adjustment for possible confounding. This study, in Pokhara city, in an area of Nepal where biomass cookstoves are widely used without direct venting of the smoke to the outdoors, focuses on pre-clinical measures of opacity, while avoiding selection bias and taking into account comprehensive data on potential confounding factors Methods Using a cross-sectional study design, severity of lenticular damage, judged on the LOCS III scales, was investigated in females (n=143), aged 20-65 years, without previously diagnosed cataract. Linear and logistic regression analyses were used to examine the relationships with stove type and length of use. Clinically significant cataract, used in the logistic regression models, was defined as a LOCS III score > 2. Results Using gas cookstoves as the reference group, logistic regression analysis for nuclear cataract showed the evidence of relationships with stove type: for biomass stoves, the odds ratio (OR) was 2.58 (95% confidence interval [CI]: 1.22-5.46) and, for kerosene stoves, the OR was 5.18 (95% CI: 0.88-30.38). Similar results were found for nuclear color (LOCS III score > 2), but no association was found with cortical cataracts. Supporting a relationship between biomass stoves and nuclear cataract was a trend with years of exposure to biomass cookstoves (p=0.01). Linear regression analyses did not show clear evidence of an association between lenticular damage and stove types. Biomass fuel used for heating was not associated with any form of opacity. Conclusions This study provides support for associations of biomass and kerosene cookstoves with nuclear opacity and change in nuclear color. The novel associations with kerosene cookstove use deserve further investigation

  19. Astigmatism of the Ex Vivo Human Lens: Surface and Gradient Refractive Index Age-Dependent Contributions.

    PubMed

    Birkenfeld, Judith; de Castro, Alberto; Marcos, Susana

    2015-08-01

    We estimated the contribution of the gradient refractive index (GRIN) and lens surfaces to lens astigmatism and lens astigmatic angle as a function of age in human donor lenses. Human lenses were imaged, ex vivo, with 3D-spectral optical coherence tomography (OCT) and their back focal length was measured using laser ray tracing. The contribution of lens surfaces and GRIN to lens astigmatism were evaluated by computational ray tracing on the GRIN lens and a homogenous equivalent index lens. Astigmatism magnitude and relative astigmatic angle of and between lens surfaces, GRIN lens, and lens with homogeneous refractive index were evaluated, and all results were correlated with age. The magnitude of astigmatism in the anterior lens surface decreased with age (slope = -0.005 diopters [D]/y; r = 0.397, P = 0.018). Posterior surface astigmatism and lens astigmatism were not age-dependent. Presence of GRIN did not alter significantly the magnitude or axis of the lens astigmatism. The astigmatism of GRIN lens and lens with homogeneous refractive index correlated with anterior lens surface astigmatism (GRIN, P = 3.9E - 6, r = 0.693; equivalent refractive index lens, P = 4.1E - 4, r = 0.565). The astigmatic angle of posterior surface, GRIN lens, and homogeneous refractive index lens did not change significantly with age. The axis of lens astigmatism is close to the astigmatic axis of the anterior lens surface. Age-related changes in lens astigmatism appear to be related to changes in the anterior lens astigmatism. The influence of the GRIN on lens astigmatism and the astigmatic axis is minor.

  20. Autofluorescence imaging of macular pigment: influence and correction of ocular media opacities

    NASA Astrophysics Data System (ADS)

    Sharifzadeh, Mohsen; Obana, Akira; Gohto, Yuko; Seto, Takahiko; Gellermann, Werner

    2014-09-01

    The healthy adult human retina contains in its macular region a high concentration of blue-light absorbing carotenoid compounds, known as macular pigment (MP). Consisting of the carotenoids lutein, zeaxanthin, and meso-zeaxanthin, the MP is thought to shield the vulnerable tissue layers in the retina from light-induced damage through its function as an optical attenuator and to protect the tissue cells within its immediate vicinity through its function as a potent antioxidant. Autofluorescence imaging (AFI) is emerging as a viable optical method for MP screening of large subject populations, for tracking of MP changes over time, and for monitoring MP uptake in response to dietary supplementation. To investigate the influence of ocular media opacities on AFI-based MP measurements, in particular, the influence of lens cataracts, we conducted a clinical trial with a large subject population (93 subjects) measured before and after cataract surgery. General AFI image contrast, retinal blood vessel contrast, and presurgery lens opacity scores [Lens Opacities Classification System III (LOCS III)] were investigated as potential predictors for image degradation. These clinical results show that lens cataracts can severely degrade the achievable pixel contrasts in the AFI images, which results in nominal MP optical density levels that are artifactually reduced. While LOCS III scores and blood vessel contrast are found to be only a weak predictor for this effect, a strong correlation exists between the reduction factor and the image contrast, which can be quantified via pixel intensity histogram parameters. Choosing the base width of the histogram, the presence or absence of ocular media opacities can be determined and, if needed, the nominal MP levels can be corrected with factors depending on the strength of the opacity.

  1. [A case of invasion of the hyaloid artery into the lens].

    PubMed

    Machida, H; Watanabe, I

    1992-11-01

    A 6-year-old boy with hyaloid artery invasion into the crystalline lens is reported. Both lenses had localized opacities and some brown membranous tissue attached to the posterior lens capsule. He had bilateral persistent hyaloid arteries, and in the right eye this vessel penetrated the lens capsule and invaded the lens. The lens opacity had not increased for 6 years. In persistent hyperplastic primary vitreous we can often see the invasion of fibrovascular tissue into the lens, and this process usually leads to destruction and absorption of the lens. This is an unusual case because the lens showed no significant changes for long period of time in spite of vascular invasion into the lens.

  2. Influence of artificial accelerated aging on the color stability and opacity of composites of different shades.

    PubMed

    Mundim, F M; Da Fonseca Roberti Garcia, L; Silva Sousa, A B; Cruvinel, D R; De Carvalho Panzeri Pires-De-Souza, F

    2010-10-01

    The aim of this study was to evaluate the influence of artificial accelerated aging on the color stability and opacity of composites of different shades. Four composites for direct use (Heliomolar, 4 Seasons, Tetric EvoCeram; QuiXfil) and one for indirect use (SR Adoro) in two shades were used: light (A2) and dark (C3 for direct, and D4 for indirect composite). QuiXfil was obtained in Universal shade. A Teflon matrix (12 X 2 mm) was used to obtain 54 specimens (N=6), which were submitted to color and opacity analysis (Spectrophotometer PCB 6807, Byk Gardner) before and after artificial accelerated aging for 384 hours. After the statistical analysis (2-way ANOVA - Bonferroni - P<0.05), significant color alteration was observed in the light and dark composites studied (P<0.05), with the exception of QuiXfil. Composite 4 Seasons/C3 showed less color alteration (ΔE=0.91). The opacity alteration (ΔOP) was higher for light composites. Artificial accelerated aging interfered in the optical properties assessed; however, the alterations seemed to be more related to the composites composition than to their shade.

  3. Germ-line and somatic EPHA2 coding variants in lens aging and cataract.

    PubMed

    Bennett, Thomas M; M'Hamdi, Oussama; Hejtmancik, J Fielding; Shiels, Alan

    2017-01-01

    Rare germ-line mutations in the coding regions of the human EPHA2 gene (EPHA2) have been associated with inherited forms of pediatric cataract, whereas, frequent, non-coding, single nucleotide variants (SNVs) have been associated with age-related cataract. Here we sought to determine if germ-line EPHA2 coding SNVs were associated with age-related cataract in a case-control DNA panel (> 50 years) and if somatic EPHA2 coding SNVs were associated with lens aging and/or cataract in a post-mortem lens DNA panel (> 48 years). Micro-fluidic PCR amplification followed by targeted amplicon (exon) next-generation (deep) sequencing of EPHA2 (17-exons) afforded high read-depth coverage (1000x) for > 82% of reads in the cataract case-control panel (161 cases, 64 controls) and > 70% of reads in the post-mortem lens panel (35 clear lens pairs, 22 cataract lens pairs). Novel and reference (known) missense SNVs in EPHA2 that were predicted in silico to be functionally damaging were found in both cases and controls from the age-related cataract panel at variant allele frequencies (VAFs) consistent with germ-line transmission (VAF > 20%). Similarly, both novel and reference missense SNVs in EPHA2 were found in the post-mortem lens panel at VAFs consistent with a somatic origin (VAF > 3%). The majority of SNVs found in the cataract case-control panel and post-mortem lens panel were transitions and many occurred at di-pyrimidine sites that are susceptible to ultraviolet (UV) radiation induced mutation. These data suggest that novel germ-line (blood) and somatic (lens) coding SNVs in EPHA2 that are predicted to be functionally deleterious occur in adults over 50 years of age. However, both types of EPHA2 coding variants were present at comparable levels in individuals with or without age-related cataract making simple genotype-phenotype correlations inconclusive.

  4. Germ-line and somatic EPHA2 coding variants in lens aging and cataract

    PubMed Central

    Bennett, Thomas M.; M’Hamdi, Oussama; Hejtmancik, J. Fielding

    2017-01-01

    Rare germ-line mutations in the coding regions of the human EPHA2 gene (EPHA2) have been associated with inherited forms of pediatric cataract, whereas, frequent, non-coding, single nucleotide variants (SNVs) have been associated with age-related cataract. Here we sought to determine if germ-line EPHA2 coding SNVs were associated with age-related cataract in a case-control DNA panel (> 50 years) and if somatic EPHA2 coding SNVs were associated with lens aging and/or cataract in a post-mortem lens DNA panel (> 48 years). Micro-fluidic PCR amplification followed by targeted amplicon (exon) next-generation (deep) sequencing of EPHA2 (17-exons) afforded high read-depth coverage (1000x) for > 82% of reads in the cataract case-control panel (161 cases, 64 controls) and > 70% of reads in the post-mortem lens panel (35 clear lens pairs, 22 cataract lens pairs). Novel and reference (known) missense SNVs in EPHA2 that were predicted in silico to be functionally damaging were found in both cases and controls from the age-related cataract panel at variant allele frequencies (VAFs) consistent with germ-line transmission (VAF > 20%). Similarly, both novel and reference missense SNVs in EPHA2 were found in the post-mortem lens panel at VAFs consistent with a somatic origin (VAF > 3%). The majority of SNVs found in the cataract case-control panel and post-mortem lens panel were transitions and many occurred at di-pyrimidine sites that are susceptible to ultraviolet (UV) radiation induced mutation. These data suggest that novel germ-line (blood) and somatic (lens) coding SNVs in EPHA2 that are predicted to be functionally deleterious occur in adults over 50 years of age. However, both types of EPHA2 coding variants were present at comparable levels in individuals with or without age-related cataract making simple genotype-phenotype correlations inconclusive. PMID:29267365

  5. Alpha-A crystallin: quantitation of C-terminal modification during lens aging

    NASA Technical Reports Server (NTRS)

    Takemoto, L.; Gopalakrishnan, S.; Spooner, B. S. (Principal Investigator)

    1994-01-01

    Previous studies have demonstrated that the C-terminal region of alpha-A crystallin is susceptible to age-dependent, posttranslational modification. To quantitate the amount of modification, alpha-A crystallin was purified from total proteins of the aging bovine lens, then digested with lys-C endoproteinase. Reverse phase, high pressure liquid chromatography was used to resolve and quantitate the resulting peptides, to determine the amount of C-terminal peptide relative to peptides from other regions of the protein that have not been reported to undergo modification. The results indicate that relative to alpha-A crystallin from newborn lens, posttranslational modification has occurred in approximately 45-55% of the C-terminal region from mature lens. These results demonstrate extensive modification of the C-terminal region of alpha-A crystallin from the mature lens, indicating that during the aging process, posttranslational modifications in this region may make significant contributions to the aggregated state and/or molecular chaperone properties of the molecule.

  6. In vivo measurement of age-related stiffening in the crystalline lens by Brillouin optical microscopy.

    PubMed

    Scarcelli, Giuliano; Kim, Pilhan; Yun, Seok Hyun

    2011-09-21

    The biophysical and biomechanical properties of the crystalline lens (e.g., viscoelasticity) have long been implicated in accommodation and vision problems, such as presbyopia and cataracts. However, it has been difficult to measure such parameters noninvasively. Here, we used in vivo Brillouin optical microscopy to characterize material acoustic properties at GHz frequency and measure the longitudinal elastic moduli of lenses. We obtained three-dimensional elasticity maps of the lenses in live mice, which showed biomechanical heterogeneity in the cortex and nucleus of the lens with high spatial resolution. An in vivo longitudinal study of mice over a period of 2 months revealed a marked age-related stiffening of the lens nucleus. We found remarkably good correlation (log-log linear) between the Brillouin elastic modulus and the Young's modulus measured by conventional mechanical techniques at low frequencies (~1 Hz). Our results suggest that Brillouin microscopy is potentially useful for basic and animal research and clinical ophthalmology. Copyright © 2011 Biophysical Society. Published by Elsevier Inc. All rights reserved.

  7. Ocular Risk Factors for Age-related Macular Degeneration: The Los Angeles Latino Eye Study (LALES)

    PubMed Central

    Fraser-Bell, Samantha; Choudhury, Farzana; Klein, Ronald; Azen, Stanley; Varma, Rohit

    2010-01-01

    Purpose To assess the association of ocular factors and age-related macular degeneration (AMD) in Latinos. Design Population-based, cross-sectional study of 6357 self-identified Latinos aged 40 years and older. Methods Ophthalmic examination included subjective refraction, measurement of axial length, evaluation of iris color, Lens Opacities Classification System II (LOCS II) grading of cataracts, and stereoscopic macular photographs for AMD lesions. Generalized estimating equation analysis incorporated data from both eyes to estimate odds ratios adjusted for covariates. Results After controlling for confounders (age, gender and smoking), prior cataract surgery was associated with advanced AMD (OR: 2.8, 95% CI 1.0, 7.8), increased retinal pigment (OR: 1.6, 95% CI 1.0, 1.5) and retinal pigment epithelial depigmentation (OR: 2.2, 95% CI 1.1, 4.4). The presence of any lens opacity was associated with soft drusen (OR: 1.2; 95% CI 1.0, 1.5). Longer axial length (per mm) was associated with a decreased odds of soft drusen, increased retinal pigment, and geographic atrophy (GA) (ORs: 0.8 [95% CI 0.7, 0.9], 0.8 [95% CI 0.7, 0.9], 0.7 [95% CI 0.5, 0.9], respectively. Myopia was inversely associated with soft drusen (OR: 0.8; 95% CI 0.7, 1.0). Lighter colored irises were associated with GA (OR: 5.0; 95% CI 1.0, 25.3). Conclusions Cross-sectional associations of ocular factors such as cataract, cataract surgery, and refractive errors with early AMD lesions found in Latinos were consistent with those in whites. Additionally, prior cataract surgery was associated with advanced AMD. PMID:20138605

  8. Risk Factors Associated with Age-Related Macular Degeneration

    PubMed Central

    2006-01-01

    Objective: To investigate possible risk factors for age-related macular degeneration (AMD) in participants in the Age-Related Eye Disease Study (AREDS). Design: Case-control study. Participants: Of the 4757 persons enrolled in AREDS, 4519 persons aged 60 to 80 years were included in this study. The lesions associated with AMD ranged from absent in both eyes to advanced in one eye. Main Outcome Measures: Stereoscopic color fundus photographs of the macula were used to place participants into one of five groups, based on the frequency and severity of lesions associated with AMD. Participants with fewer than 15 small drusen served as the control group. Results: Staged model building techniques were used to compare each of the four case groups with the control group. Increased age was a consistent finding of all four of the case groups compared with the control group, and all the following associations were age adjusted. Persons with either intermediate drusen, extensive small drusen, or the pigment abnormalities associated with AMD (group 2) were more likely to be female, more likely to have a history of arthritis, and less likely to have a history of angina. Persons with one or more large drusen or extensive intermediate drusen (group 3) were more likely to use hydrochlorothiazide diuretics and more likely to have arthritis. Hypertension, hyperopia, presence of lens opacities, and white race were also found more frequently in this group as well as in persons with neovascular AMD (group 5). Only persons in group 5 were more likely to have an increased body mass index, whereas persons with geographic atrophy (group 4) as well as those in groups 3 and 5 were more likely to have completed fewer years in school or to be smokers. Those with geographic atrophy were also more likely to use thyroid hormones and antacids. Conclusions: Our findings for smoking and hypertension, which have been noted in previous studies, suggest that two important public health recommendations

  9. Wavefront aberrations and retinal image quality in different lenticular opacity types and densities.

    PubMed

    Wu, Cheng-Zhe; Jin, Hua; Shen, Zhen-Nv; Li, Ying-Jun; Cui, Xun

    2017-11-10

    To investigate wavefront aberrations in the entire eye and in the internal optics (lens) and retinal image qualities according to different lenticular opacity types and densities. Forty-one eyes with nuclear cataract, 33 eyes with cortical cataract, and 29 eyes with posterior subcapsular cataract were examined. In each group, wavefront aberrations in the entire eye and in the internal optics and retinal image quality were measured using a raytracing aberrometer. Eyes with cortical cataracts showed significantly higher coma-like aberrations compared to the other two groups in both entire eye and internal optic aberrations (P = 0.012 and P = 0.007, respectively). Eyes with nuclear cataract had lower spherical-like aberrations than the other two groups in both entire eye and internal optics aberrations (P < 0.001 and P < 0.001, respectively). In the nuclear cataract group, nuclear lens density was negatively correlated with internal spherical aberrations (r = -0.527, P = 0.005). Wavefront technology is useful for objective and quantitative analysis of retinal image quality deterioration in eyes with different early lenticular opacity types and densities. Understanding the wavefront optical properties of different crystalline lens opacities may help ophthalmic surgeons determine the optimal time to perform cataract surgery.

  10. In Vivo Measurement of Age-Related Stiffening in the Crystalline Lens by Brillouin Optical Microscopy

    PubMed Central

    Scarcelli, Giuliano; Kim, Pilhan; Yun, Seok Hyun

    2011-01-01

    Abtract The biophysical and biomechanical properties of the crystalline lens (e.g., viscoelasticity) have long been implicated in accommodation and vision problems, such as presbyopia and cataracts. However, it has been difficult to measure such parameters noninvasively. Here, we used in vivo Brillouin optical microscopy to characterize material acoustic properties at GHz frequency and measure the longitudinal elastic moduli of lenses. We obtained three-dimensional elasticity maps of the lenses in live mice, which showed biomechanical heterogeneity in the cortex and nucleus of the lens with high spatial resolution. An in vivo longitudinal study of mice over a period of 2 months revealed a marked age-related stiffening of the lens nucleus. We found remarkably good correlation (log-log linear) between the Brillouin elastic modulus and the Young's modulus measured by conventional mechanical techniques at low frequencies (∼1 Hz). Our results suggest that Brillouin microscopy is potentially useful for basic and animal research and clinical ophthalmology. PMID:21943436

  11. Distribution of the Crystalline Lens Power In Vivo as a Function of Age.

    PubMed

    Jongenelen, Sien; Rozema, Jos J; Tassignon, Marie-José

    2015-11-01

    To observe the age-related changes in crystalline lens power in vivo in a noncataractous European population. Data were obtained though Project Gullstrand, a multicenter population study with data from healthy phakic subjects between 20 and 85 years old. One randomly selected eye per subject was used. Lens power was calculated using the modified Bennett-Rabbetts method, using biometry data from an autorefractometer, Oculus Pentacam, and Haag-Streit Lenstar. The study included 1069 Caucasian subjects (490 men, 579 women) with a mean age of 44.2 ± 14.2 years and mean lens power of 24.96 ± 2.18 diopters (D). The average lens power showed a statistically significant decrease as a function of age, with a steeper rate of decrease after the age of 55. The highest crystalline lens power was found in emmetropic eyes and eyes with a short axial length. The correlation of lens power with different refractive components was statistically significant for axial length (r = -0.523, P < 0.01) and anterior chamber depth (r = -0.161, P < 0.01), but not for spherical equivalent and corneal power (P > 0.05). This in vivo study showed a monotonous decrease in crystalline lens power with age, with a steeper decline after 55 years. While this finding fundamentally concurs with previous in vivo studies, it is at odds with studies performed on donor eyes that reported lens power increases after the age of 55.

  12. The Associations of Lens Power With Age and Axial Length in Healthy Chinese Children and Adolescents Aged 6 to 18 Years.

    PubMed

    Xiong, Shuyu; Zhang, Bo; Hong, Yuan; He, Xiangui; Zhu, Jianfeng; Zou, Haidong; Xu, Xun

    2017-11-01

    To investigate the relationship between lens power and age as well as the relationship between lens power and axial length (AL) in Chinese children and adolescents. The participants underwent a comprehensive ophthalmic examination that included AL, cycloplegic refraction, and Pentacam measurements. The crystalline lens power was calculated using Bennett's formula and then compared among the children of different age groups, refractive statuses, and AL categories. The association of lens power and AL was analyzed using multiple regression. A total of 1992 children and adolescents aged 6- to 18-years old were included. The difference in lens power was greater before 10-years old, followed by a relatively smaller difference in children aged 10 to 14 years and the difference in lens power came to a near plateau in adolescents after 14-years old. The negative association between lens power and AL was found to be more evident in nonmyopes than in myopes irrespective of age (younger than 10 years: nonmyopes: β = -1.499, myopes: β = -0.872; older than 10 years: nonmyopes: β = -1.288, myopes: β = -0.390, all P < 0.001). The lens power in children and adolescents aged 6 to 18 years exhibited three stages. The association between lens power and AL differed between the nonmyopes and myopes. These findings suggested that less reduction in lens power might be associated with both growing age and increasing AL in myopes.

  13. Assessing Age-Related Changes in the Biomechanical Properties of Rabbit Lens Using a Coaligned Ultrasound and Optical Coherence Elastography System

    PubMed Central

    Wu, Chen; Han, Zhaolong; Wang, Shang; Li, Jiasong; Singh, Manmohan; Liu, Chih-hao; Aglyamov, Salavat; Emelianov, Stanislav; Manns, Fabrice; Larin, Kirill V.

    2015-01-01

    Purpose. To evaluate the capability of a novel, coaligned focused ultrasound and phase-sensitive optical coherence elastography (US-OCE) system to assess age-related changes in biomechanical properties of the crystalline lens in situ. Methods. Low-amplitude elastic deformations in young and mature rabbit lenses were measured by an US-OCE system consisting of a spectral-domain optical coherence tomography (OCT) system coaligned with a focused ultrasound system used to produce a transient force on the lens surface. Uniaxial compressional tests were used to validate the OCE data. Results. The OCE measurements showed that the maximum displacements of the young rabbit lenses were significantly larger than those of the mature lenses, indicating a gradual increase of the lens stiffness with age. Temporal analyses of the displacements also demonstrate a similar trend of elastic properties in these lenses. The stress-strain measurements using uniaxial mechanical tests confirmed the results obtained by the US-OCE system. Conclusions. The results demonstrate that the US-OCE system can be used for noninvasive analysis and quantification of lens biomechanical properties in situ and possibly in vivo. PMID:25613945

  14. Altered DNA Methylation and Expression Profiles of 8-Oxoguanine DNA Glycosylase 1 in Lens Tissue from Age-related Cataract Patients.

    PubMed

    Wang, Yong; Li, Fei; Zhang, Guowei; Kang, Lihua; Qin, Bai; Guan, Huaijin

    2015-01-01

    Oxidative stress and DNA damage contribute to the pathogenesis of age-related cataract (ARC). Most oxidative DNA lesions are repaired via the base excision repair (BER) proteins including 8-oxoguanine DNA glycosylase 1 (OGG1). This study examined DNA methylation of CpG islands upstream of OGG1 and their relation to the gene expression in lens cortex from ARC patients. The clinical case-control study consisted of 15 cortical type of ARC patients and 15 age-matched non-ARC controls who received transparent lens extraction due to vitreoretinal diseases. OGG1 expression in lens cortex was analyzed by qRT-PCR and Western blot. The localization and the proportion of cells positive for OGG1 were determined by immunofluorescence. Bisulfite-sequencing PCR (BSP) was performed to evaluate the methylation status of CpG islands near OGG1 in DNA extracted from lens cortex. To test relationship between the methylation and the expression of the gene of interest, 5-Aza-2'-deoxycytidine (5-Aza-dC) was used to induce demethylation of cultured human lens epithelium B-3 (HLE B-3). To test the role of OGG1 in the repair of cellular damage, HLE B-3 was transfected with OGG1 vector, followed by ultraviolet radiation b (UVB) exposure to induce apoptosis. The mRNA and protein levels of OGG1 were significantly reduced in the lens cortex of ARC. Immunofluorescence showed that the proportion of OGG1-positive cells decreased significantly in ARC cortex in comparison with the control. The CpG island in first exon of OGG1 displayed hypermethylation in the DNA extracted from the lens cortex of ARC. Treatment of HLEB-3 cells with 5-Aza-dC upregulated OGG1 expression. UVB-induced apoptosis was attenuated after transfection with OGG1. A reduced OGG1 expression was correlated with hypermethylation of a CpG island of OGG1 in lens cortex of ARC. The role of epigenetic change in OGG1 gene in the susceptibility to oxidative stress induced cortical ARC is warranted to further study.

  15. Colour stability and opacity of resin cements and flowable composites for ceramic veneer luting after accelerated ageing.

    PubMed

    Archegas, Lucí Regina Panka; Freire, Andrea; Vieira, Sergio; Caldas, Danilo Biazzetto de Menezes; Souza, Evelise Machado

    2011-11-01

    Colour changes of the luting material can become clinically visible affecting the aesthetic appearance of thin ceramic laminates. The aim of this in vitro study was to evaluate the colour stability and opacity of light- and dual-cured resin cements and flowable composites after accelerated ageing. The luting agents were bonded (0.2 mm thick) to ceramic disks (0.75 mm thick) built with the pressed-ceramic IPS Aesthetic Empress (n=7). Colour measurements were determined using a FTIR spectrophotometer before and after accelerated ageing in a weathering machine with a total energy of 150 kJ. Changes in colour (ΔE) and opacity (ΔO) were obtained using the CIE L*a*b* system. The results were submitted to one-way ANOVA, Tukey HSD test and Student's t test (α=5%). All the materials showed significant changes in colour and opacity. The ΔE of the materials ranged from 0.41 to 2.40. The highest colour changes were attributed to RelyX ARC and AllCem, whilst lower changes were found in Variolink Veneer, Tetric Flow and Filtek Z350 Flow. The opacity of the materials ranged from -0.01 to 1.16 and its variation was not significant only for Opallis Flow and RelyX ARC. The accelerated ageing led to colour changes in all the evaluated materials, although they were considered clinically acceptable (ΔE<3). Amongst the dual-cured resin cements, Variolink II demonstrated the highest colour stability. All the flowable composites showed proper colour stability for the luting of ceramic veneers. After ageing, an increase in opacity was observed for most of the materials. Copyright © 2011 Elsevier Ltd. All rights reserved.

  16. Anterior lens epithelium in cataract patients with retinitis pigmentosa - scanning and transmission electron microscopy study.

    PubMed

    Andjelic, Sofija; Drašlar, Kazimir; Hvala, Anastazija; Hawlina, Marko

    2017-05-01

    In retinitis pigmentosa (RP) patients, relatively minor lens opacity in central part of posterior pole of the lens may cause disproportionate functional symptoms requiring cataract operation. To investigate the possible structural reasons for this opacity development, we studied the structure of the lens epithelium of patients with RP. The anterior lens capsule (aLC: basement membrane and associated lens epithelial cells, LECs) was obtained from cataract surgery and prepared for scanning and transmission electron microscopy (SEM and TEM). Both SEM and TEM show a number of abnormal features in the anterior lens epithelium of cataract patients with RP. The abnormalities appear mainly as holes, thinning and degradation of the epithelium, with the dimensions from <1 μm to more than 50 μm. Other types of holes in size up to 20 μm were seen that may be formed by gradual stretching of the lens epithelium. Another type of abnormalities was cracks that were seen between adjacent LECs, with dimensions 0.1-2 μm × up to 10 μm. Abnormal structural features were observed in the anterior lens epithelium that may cause water influx into the lens. This may lead to clouding along the water clefts leading towards the posterior pole in the RP cataractous lens. We suggest that the lens epithelium has a role in the development of the cataract in patients with RP. © 2016 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  17. Eye lens dosimetry and the study on radiation cataract in interventional cardiologists.

    PubMed

    Matsubara, Kosuke; Lertsuwunseri, Vorarit; Srimahachota, Suphot; Krisanachinda, Anchali; Tulvatana, Wasee; Khambhiphant, Bharkbhum; Sudchai, Waraporn; Rehani, Madan

    2017-12-01

    To determine the eye lens dose of the Interventional Cardiology (IC) personnel using optically stimulated luminescent dosimeter (OSLD) and the prevalence and risk of radiation - associated lens opacities in Thailand. 48 IC staff, with age- and sex- matches 37 unexposed controls obtained eye examines. Posterior lens change was graded using a modified Merriam-Focht technique by two independent ophthalmologists. Occupational exposure (mSv) was measured in 42 IC staff, using 2 OSLD badges place at inside lead apron and at collar. Annual eye lens doses (mSv) were also measured using 4 nanoDots OSL placed outside and inside lead glass eyewear. The prevalence of radiation-associated posterior lens opacities was 28.6% (2/7) for IC, 19.5% (8/41) for nurses, and 2.7% (1/37) for controls. The average and range of annual whole body effective dose, Hp(10), equivalent dose at skin of the neck, Hp(0.07) and equivalent dose at eye lens, Hp(3) were 0.80 (0.05-6.79), 5.88 (0.14-35.28), and 5.73 (0.14-33.20) mSv respectively. The annual average and range of eye lens dose using nano Dots OSL showed the outside lead glass eyewear on left and right sides as 8.06 (0.17-32.45), 3.55(0.06-8.04) mSv and inside left and right sides as 3.91(0.05-14.26) and 2.44(0.06-6.24) mSv respectively. Eye lens doses measured by OSLD badges and nano Dot dosimeter as Hp(10), Hp(0.07) and Hp(3). The eyes of the IC personnel were examined annually by two ophthalmologists for the prevalence of cataract induced by radiation. Copyright © 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  18. Three-dimensional microscopic tomographic imagings of the cataract in a human lens in vivo

    NASA Astrophysics Data System (ADS)

    Masters, Barry R.

    1998-10-01

    The problem of three-dimensional visualization of a human lens in vivo has been solved by a technique of volume rendering a transformed series of 60 rotated Scheimpflug (a dual slit reflected light microscope) digital images. The data set was obtained by rotating the Scheimpflug camera about the optic axis of the lens in 3 degree increments. The transformed set of optical sections were first aligned to correct for small eye movements, and then rendered into a volume reconstruction with volume rendering computer graphics techniques. To help visualize the distribution of lens opacities (cataracts) in the living, human lens the intensity of light scattering was pseudocolor coded and the cataract opacities were displayed as a movie.

  19. Contact Lens-related Complications: A Review

    PubMed Central

    Alipour, Fateme; Khaheshi, Saeed; Soleimanzadeh, Mahya; Heidarzadeh, Somayeh; Heydarzadeh, Sepideh

    2017-01-01

    Contact lens-related problems are common and can result in severe sight-threatening complications or contact lens drop out if not addressed properly. We systematically reviewed the most important and the most common contact lens-related complications and their diagnosis, epidemiology, and management according to the literature published in the last 20 years. PMID:28540012

  20. Ku80 Counters Oxidative Stress-Induced DNA Damage and Cataract Formation in the Human Lens.

    PubMed

    Smith, Andrew John Oliver; Ball, Simon Sidney Robert; Manzar, Kamal; Bowater, Richard Peter; Wormstone, Ian Michael

    2015-12-01

    Oxidative stress in the human lens leads to a wide range of damage including DNA strand breaks, which are likely to contribute to cataract formation. The protein Ku80 is a fundamental component of the nonhomologous end-joining pathway that repairs DNA double strand breaks. This study investigates the putative impact of Ku80 in cataract prevention in the human lens. The present study used the human lens epithelial cell line FHL124 and whole human lens organ culture. Targeted siRNA was used to deplete Ku80, with Western blot and immunocytochemistry employed to assess Ku80 expression levels. Oxidative stress was induced with hydrogen peroxide and DNA strand breaks measured by alkaline comet assay and γH2AX foci counts. Visual quality of whole human lenses was measured with image analysis software. Expression of Ku80 was predominately found in the cell nucleus of both FHL124 cells and native human lens epithelium. Treatment of FHL124 cells and whole lens cultures with siRNA targeted against Ku80 resulted in a significant knockdown at the protein level. Application of oxidative stress (30 μM H2O2) created more DNA strand breaks when added to Ku80 knockdown cells than in scrambled siRNA control cells as determined by the alkaline comet assay and the number of γH2AX foci. In whole lens cultures, exposure to 1 mM H2O2 resulted in more lens opacity in Ku80 knockdown lenses than match-paired controls. Depletion of Ku80 in the lens through acute change or a consequence of aging is likely to increase levels of DNA strand breaks, which could negatively influence physiological function and promote lens opacity. It is therefore feasible that Ku80 plays a role in retarding cataract formation.

  1. EPHA2 Polymorphisms in Estonian Patients with Age-Related Cataract.

    PubMed

    Celojevic, Dragana; Abramsson, Alexandra; Seibt Palmér, Mona; Tasa, Gunnar; Juronen, Erkki; Zetterberg, Henrik; Zetterberg, Madeleine

    2016-01-01

    Ephrin receptors (Ephs) are tyrosine kinases that together with their ligands, ephrins, are considered important in cell-cell communication, especially during embryogenesis but also for epithelium homeostasis. Studies have demonstrated the involvement of mutations or common variants of the gene encoding Eph receptor A2 (EPHA2), in congenital cataract and in age-related cataract. This study investigated a number of disease-associated single nucleotide polymorphisms (SNPs) in EPHA2 in patients with age-related cataract. The study included 491 Estonian patients who had surgery for age-related cataract, classified as nuclear, cortical, posterior subcapsular and mixed lens opacities, and 185 controls of the same ethnical origin. Seven SNPs in EPHA2 (rs7543472, rs11260867, rs7548209, rs3768293, rs6603867, rs6678616, rs477558) were genotyped using TaqMan Allelic Discrimination. Statistical analyses for single factor associations used χ(2)-test and logistic regression was performed including relevant covariates (age, sex and smoking). In single-SNP allele analysis, only the rs7543472 showed a borderline significant association with risk of cataract (p = 0.048). Regression analysis with known risk factors for cataract showed no significant associations of the studied SNPs with cataract. Stratification by cataract subtype did not alter the results. Adjusted odds ratios were between 0.82 and 1.16 (95% confidence interval 0.61-1.60). The present study does not support a major role of EphA2 in cataractogenesis in an Estonian population.

  2. Radiation-associated lens changes in the cardiac catheterization laboratory: Results from the IC-CATARACT (CATaracts Attributed to RAdiation in the CaTh lab) study.

    PubMed

    Karatasakis, Aris; Brilakis, Harilaos S; Danek, Barbara A; Karacsonyi, Judit; Martinez-Parachini, Jose Roberto; Nguyen-Trong, Phuong-Khanh J; Alame, Aya J; Roesle, Michele K; Rangan, Bavana V; Rosenfield, Kenneth; Mehran, Roxana; Mahmud, Ehtisham; Chambers, Charles E; Banerjee, Subhash; Brilakis, Emmanouil S

    2018-03-01

    To examine the relationship between occupational exposure to ionizing radiation and the prevalence of lens changes in interventional cardiologists (ICs) and catheterization laboratory ("cath-lab") staff. Exposure to ionizing radiation is associated with the development of lens opacities. ICs and cath-lab staff can receive high doses of ionizing radiation without protection, and may thus be at risk for lens opacity formation. We conducted a cross-sectional study at an interventional cardiology conference. Study participants completed a questionnaire pertaining to occupational exposure to radiation and potential confounders for the development of cataracts, followed by slit-lamp examination and grading of lens findings. A total of 117 attendees participated in the study, including 99 (85%; 49 ± 11 years-old; 82% male) with occupational exposure to ionizing radiation and 18 (15%; 39 ± 12 years-old; 61% male) unexposed controls. The prevalence of overall cortical and posterior subcapsular lens changes (including subclinical findings) was higher in exposed participants compared with controls (47 vs. 17%, P = 0.015). Occupational exposure and age over 60 were independent predictors of lens changes (odds ratio [95% CI]: 6.07 [1.38-43.45] and 7.72 [1.60-43.34], respectively). The prevalence of frank opacities was low and similar between the two groups (14 vs. 6%, P = 0.461). Most lens findings consisted of subclinical changes in the periphery of the lens without impact on visual acuity. Compared with unexposed controls, ICs and cath-lab staff had a higher prevalence of lens changes that may be attributable to ionizing radiation exposure. While most of these changes were subclinical, they are important due to the potential to progress to clinical symptoms, highlighting the importance of minimizing staff radiation exposure. © 2017 Wiley Periodicals, Inc.

  3. Disease and Surgery of the Equine Lens.

    PubMed

    Townsend, Wendy M

    2017-12-01

    Examination of the lens is critical, particularly when evaluating horses with visual impairment or performing prepurchase examinations. To adequately evaluate the lens, the pupil must be pharmacologically dilated. A cataract is any lens opacity. The size, density, and position of a cataract determine the impact on vision. Cataracts may be congenital or inherited or occur secondary to trauma or equine recurrent uveitis. Surgical removal is the only treatment option for vision impairing cataracts, but careful selection of surgical candidates is critical for successful outcomes. Copyright © 2017 Elsevier Inc. All rights reserved.

  4. Age-related changes in the water-soluble lens protein composition of Wistar and accelerated-senescence OXYS rats

    PubMed Central

    Kopylova, Lyudmila V.; Cherepanov, Ivan V.; Snytnikova, Olga A.; Rumyantseva, Yuliya V.; Kolosova, Nataliya G.; Sagdeev, Renad Z.

    2011-01-01

    Purpose To determine the age-related and the cataract-specific changes in the crystallin composition in lenses of accelerated-senescence OXYS (cataract model) and Wistar (control) rats. Methods The water soluble (WS) and insoluble (WIS) fractions of the lens proteins were separated; the identity and relative abundance of each crystallin in WS fraction were determined with the use of two-dimensional electrophoresis (2-DE) and Matrix-Assisted Laser Desorption Ionization – Time Of Flight (MALDI-TOF) mass spectrometry. All statistical calculations were performed using the software package Statistica 6.0 by factor dispersion analysis (ANOVA/MANOVA) and Newman-Keuls post-hoc test for comparison of group mean values. Results The WIS protein content increased significantly in the aged animal lenses; the WIS/WS ratio increases in approximately 8 times to the age of 62 weeks. The interstrain difference was insignificant in this experiment. 2-DE maps of the young rat lenses (3 weeks) showed single spots for each lens protein while in older lenses (12 and 62 weeks) each crystallin was presented by several spots. The abundance of γA-γF-crystallins in WS fraction significantly decreases with age. A significant increase in the percentage abundance was also found for α-crystallins and βB2-crystallin from 3 to 12 weeks. The major differences between Wistar and OXYS lenses are the faster decay of the content of γA-γF-crystallins in OXYS lenses, and the significant decrease of unmodified αA-crystallin abundance in old OXYS lenses. Conclusions The presented results demonstrate that the increase of the water-insoluble (WIS) protein fraction is rather age-specific than cataract-specific phenomenon. The major age-related changes in WS protein composition are the fast insolubilization of γ-crystallins, and the increase of αB- and βB2-crystallin abundance. The main interstrain differences, which could be attributed to the cataract-specific processes, are the faster decay of the

  5. Color and opacity of composites protected with surface sealants and submitted to artificial accelerated aging.

    PubMed

    Aguilar, Fabiano Gamero; Roberti Garcia, Lucas da Fonseca; Cruvinel, Diogo Rodrigues; Sousa, Ana Beatriz Silva; de Carvalho Panzeri Pires-de-Souza, Fernanda

    2012-01-01

    To evaluate the color similarity, stability and opacity of composites (TPH, Charisma, and Concept, shade A2) protected with surface sealants (Fortify Plus and Biscover) and cyanoacrylate (Super Bonder). Forty specimens of each composite were made and separated into 4 groups (n=10) according to the surface protection: GI - without sealant; GII - cyanoacrylate; GIII - Fortify Plus; GIV - Biscover. Color and opacity readings were taken before and after Artificial Acelerated Aging (AAA) and the values obtained for color stability were submitted to statistical analysis by 2-way ANOVA and Bonferroni's test (P<.05). The values acquired for color similarity were submitted to 1-way ANOVA and Tukey's test (P<.05). The specimen sufaces were compared before and after AAA using Scanning Electronic Microscopy (SEM). Studied composites did not present the same values for the coordinates L*, a* and b * before AAA, indicating that there was no color similarity among them. All composites presented color alteration after AAA with clinically unacceptable values. Protected groups presented lower opacity variation after AAA, in comparison with the control goup. SEM evaluation demonstrated that AAA increased the surface irregularities in all of the studied groups. Surface sealants were not effective in maintaining composite color, but were able to maintain opacity.

  6. Aquaporin 0 Modulates Lens Gap Junctions in the Presence of Lens-Specific Beaded Filament Proteins

    PubMed Central

    Kumari, Sindhu; Gao, Junyuan; Mathias, Richard T.; Sun, Xiurong; Eswaramoorthy, Amizhdini; Browne, Nicholas; Zhang, Nigel

    2017-01-01

    Purpose The objective of this study was to understand the molecular and physiologic mechanisms behind the lens cataract differences in Aquaporin 0-knockout-Heterozygous (AQP0-Htz) mice developed in C57 and FVB (lacks beaded filaments [BFs]) strains. Methods Lens transparency was studied using dark field light microscopy. Water permeability (Pf) was measured in fiber cell membrane vesicles. Western blotting/immunostaining was performed to verify expression of BF proteins and connexins. Microelectrode-based intact lens intracellular impedance was measured to determine gap junction (GJ) coupling resistance. Lens intracellular hydrostatic pressure (HP) was determined using a microelectrode/manometer system. Results Lens opacity and spherical aberration were more distinct in AQP0-Htz lenses from FVB than C57 strains. In either background, compared to wild type (WT), AQP0-Htz lenses showed decreased Pf (approximately 50%), which was restored by transgenic expression of AQP1 (TgAQP1/AQP0-Htz), but the opacities and differences between FVB and C57 persisted. Western blotting revealed no change in connexin expression levels. However, in C57 AQP0-Htz and TgAQP1/AQP0-Htz lenses, GJ coupling resistance decreased approximately 2.8-fold and the HP gradient decreased approximately 1.9-fold. Increased Pf in TgAQP1/AQP0-Htz did not alter GJ coupling resistance or HP. Conclusions In C57 AQP0-Htz lenses, GJ coupling resistance decreased. HP reduction was smaller than the coupling resistance reduction, a reflection of an increase in fluid circulation, which is one reason for the less severe cataract in C57 than FVB. Overall, our results suggest that AQP0 modulates GJs in the presence of BF proteins to maintain lens transparency and homeostasis. PMID:29196765

  7. Aquaporin 0 Modulates Lens Gap Junctions in the Presence of Lens-Specific Beaded Filament Proteins.

    PubMed

    Kumari, Sindhu; Gao, Junyuan; Mathias, Richard T; Sun, Xiurong; Eswaramoorthy, Amizhdini; Browne, Nicholas; Zhang, Nigel; Varadaraj, Kulandaiappan

    2017-12-01

    The objective of this study was to understand the molecular and physiologic mechanisms behind the lens cataract differences in Aquaporin 0-knockout-Heterozygous (AQP0-Htz) mice developed in C57 and FVB (lacks beaded filaments [BFs]) strains. Lens transparency was studied using dark field light microscopy. Water permeability (Pf) was measured in fiber cell membrane vesicles. Western blotting/immunostaining was performed to verify expression of BF proteins and connexins. Microelectrode-based intact lens intracellular impedance was measured to determine gap junction (GJ) coupling resistance. Lens intracellular hydrostatic pressure (HP) was determined using a microelectrode/manometer system. Lens opacity and spherical aberration were more distinct in AQP0-Htz lenses from FVB than C57 strains. In either background, compared to wild type (WT), AQP0-Htz lenses showed decreased Pf (approximately 50%), which was restored by transgenic expression of AQP1 (TgAQP1/AQP0-Htz), but the opacities and differences between FVB and C57 persisted. Western blotting revealed no change in connexin expression levels. However, in C57 AQP0-Htz and TgAQP1/AQP0-Htz lenses, GJ coupling resistance decreased approximately 2.8-fold and the HP gradient decreased approximately 1.9-fold. Increased Pf in TgAQP1/AQP0-Htz did not alter GJ coupling resistance or HP. In C57 AQP0-Htz lenses, GJ coupling resistance decreased. HP reduction was smaller than the coupling resistance reduction, a reflection of an increase in fluid circulation, which is one reason for the less severe cataract in C57 than FVB. Overall, our results suggest that AQP0 modulates GJs in the presence of BF proteins to maintain lens transparency and homeostasis.

  8. Compliance factors associated with contact lens-related dry eye.

    PubMed

    Ramamoorthy, Padmapriya; Nichols, Jason Jay

    2014-01-01

    To determine if compliance factors are associated with contact lens-related dry eye (CLDE). The data were derived from subject responses to a compliance survey administered in a cross-sectional study including 100 healthy, daily (nonovernight), experienced soft contact lens wearers (50 normal and 50 with CLDE). Classification into normal or CLDE groups was based on Contact Lens Dry Eye Questionnaire scores, tear breakup time, and 2 hours difference between total and comfortable daily lens wear hours. The compliance survey queried aspects of lens care, rub and rinse practices, lens and lens case replacement frequency, solution replacement, and sleeping with lenses. Statistical analysis of the data was performed using unpaired T tests, χ, and Fisher exact tests as applicable. The average age of all subjects was 24.8±4.4 years, and 60% were women. Overall compliance rates were low for several variables including recommended replacement of contact lenses (53%), rub and rinse practices (69% and 45%, respectively), care solution topping-off (80%), and washing hands before handling lenses (48%). However, almost no compliance factors were associated with CLDE status, with the exception of perceived ease or difficulty with lens care, which was rated as more difficult by the CLDE group (P=0.004). Overall compliance rates with contact lens care practices are very low, highlighting the need for more effective methods of patient education regarding contact lens care and compliance. However, almost no compliance factors were found to be associated with CLDE. Factors other than compliance likely play a bigger role in CLDE.

  9. [Non-invasive, spatially resolved determination of tissue properties of the crystalline lens with regard to rheology, refractive index, density and protein concentration by using Brillouin spectroscopy].

    PubMed

    Reiss, S; Stachs, O; Guthoff, R; Stolz, H

    2011-12-01

    The confocal Brillouin spectroscopy is an innovative measurement method that allows the non-invasive determination of the rheological properties of materials. Its application in ophthalmology can offer the possibility to determine in-vivo the deformation properties of sections of transparent biological tissue such as the cornea or eye lens with spatial resolution. This seems to be a promising approach concerning current presbyopia research. Due to the spatially resolved detection of the viscoelastic lens properties, a better understanding of the natural aging process of the lens and the influences of different lens opacities on the stiffness is expected. From the obtained spectral data the relative protein levels, the relative refractive index profile and the relative density profile within the lens tissue can be derived in addition. A measurement set-up for confocal Brillouin microscopy based on spectral analysis of spontaneous Brillouin scattering signals by using a high-resolution dispersive device is presented. First in-vitro test results on animal and human lenses are presented and evaluated concerning their rheological significance. These data are compared with known research results. © Georg Thieme Verlag KG Stuttgart · New York.

  10. [Rules and regulations concerning contact lens-related infection].

    PubMed

    Feys, J

    2004-04-01

    Contact lens-related infectious keratitis is a potentially sight-threatening complication. Bacterial keratitis, mostly due to Gram-negative bacteria, is associated with poor lens hygiene, overnight wear, and contaminated lens care solutions. Contamination of the lens storage case may cause fungal keratitis. Acanthamoeba infection is related to the use of tap water or swimming while wearing soft lenses. Viruses are of less concern among contact lens wearers. Possible transmission of Creutzfeldt-Jakob disease by multi-patient trial lenses must be taken in account. To minimize these risk factors, regulations are applied at various levels: CE marking of contact lenses and care products as they are medical devices; contact lens fitting only by health care professionals; distribution of contact lenses by opticians and lens care solutions by opticians and pharmacists; hygienic management of trial lenses following official recommendations. Contact lens-related keratitis must be reported to health care Authorities.

  11. Eye lens radiation exposure to interventional cardiologists: a retrospective assessment of cumulative doses.

    PubMed

    Jacob, Sophie; Donadille, Laurent; Maccia, Carlo; Bar, Olivier; Boveda, Serge; Laurier, Dominique; Bernier, Marie-Odile

    2013-03-01

    Radiation dose to the eye lens is a crucial issue for interventional cardiologists (ICs) who are exposed during the procedures they perform. This paper presents a retrospective assessment of the cumulative eye lens doses of ICs enrolled in the O'CLOC study for Occupational Cataracts and Lens Opacities in interventional Cardiology. Information on the workload in the catheterisation laboratory, radiation protection equipment, eye lens dose per procedure and dose reduction factors associated with eye-protective equipment were considered. For the 129 ICs at an average age of 51 who had worked for an average period of 22 years, the estimated cumulative eye lens dose ranged from 25 mSv to more than 1600 mSv; the mean ± SD was 423 ± 359 mSv. After several years of practice, without eye protection, ICs may exceed the new ICRP lifetime eye dose threshold of 500 mSv and be at high risk of developing early radiation-induced cataracts. Radiation protection equipment can reduce these doses and should be used routinely.

  12. Changes in the crystalline lens resulting from insertion of a phakic IOL (ICL) into the porcine eye.

    PubMed

    Fujisawa, Kunitoshi; Shimizu, Kimiya; Uga, Shigekazu; Suzuki, Masanobu; Nagano, Koichi; Murakami, Yuuki; Goseki, Hiroko

    2007-01-01

    Insertion of a phakic IOL offers these advantages: the corneal optical zone is not dissected or resected; preservation of the crystalline lens results in preservation of the accommodation force; and since the phakic IOL is removable, any error or change in refraction can be countered by exchanging it. However, the cause of secondary cataracts has never been clarified or discussed to date. The following ICL lenses were inserted under general anaesthesia into 20 eyes of ten 3-month-old miniature pigs: a minus lens without holes into five eyes, a plus lens in two eyes, a minus lens with four holes around the lens haptics in three eyes, and a minus lens with a central hole in the optic in three eyes; and seven eyes were used as controls. The anterior segments were then photographed 1 week, 1 month and 3 months after surgery. At 3 months after surgery, Evans blue (EB) was infused into the vitreous under general anaesthesia, and after 30 min, the eyeball was enucleated, fixed and examined. In the case of the ICL without holes, the anterior subcapsular opacities were observed in all the eyes, and the anterior surfaces of the crystalline lenses were not stained with EB. Use of the ICL with four holes around the lens haptics resulted in light staining of the anterior surface of the crystalline lens, but the anterior subcapsular opacities observed were mild. As for the ICL with a hole in the centre of the optic, the anterior surface of the crystalline lens was stained and no anterior subcapsular opacities were observed. The results suggested that the insertion of an ICL brings about a change in the dynamics of the intraocular aqueous humour, reducing its circulation to the anterior surface of the crystalline lens. This is considered to cause a metabolic disturbance of the crystalline lens, resulting in anterior subcapsular opacification.

  13. [Toxicity of ethylene oxide on the crystalline lense in an occupational milieu. Difficulty of epidemiologic surveys of cataract].

    PubMed

    Deschamps, D; Leport, M; Cordier, S; Laurent, A M; Festy, B; Hamard, H; Renard, G; Pouliquen, Y; Conso, F

    1990-01-01

    Ethylene oxide is a sterilizing gas for heat-sensitive materials. Eight cases of subcapsular cataract were attributed to this compound from 1982 to 1985. This epidemiological study was conducted in 55 persons to determine the prevalence of lens opacities and cataracts in workers exposed to this gas. The 21 persons of more than 45 years of age were then compared to 16 non-exposed persons matched for age and gender. Lens opacities (independently of visual acuity) were observed in 19 of the 55 exposed. Among exposed and non-exposed persons of more than 45 years of age, there were no significantly differences with regard to the following characteristics of lens opacities: prevalence (13 in the 21 exposed; 10 in the 16 non-exposed), distribution of the localisations, morphology and importance of the cortical opacities. No link was found between the characteristics of the lens opacities and the characteristics of the exposure: habitual exposure and accidental overexposures. For cataracts, defined by the association of lens opacities and a visual acuity less than 20/25 (this loss not being attributable to another cause), their prevalence differed significantly (p less than 0.05) between the exposed (6 of 21) and the non-exposed (0 of 16). There was no relation between their existence and accidental overexposures. The risk of lens opacification by ethylene oxide, established in cases of massive exposures as previously described, could also exist during chronic exposure to low concentrations, but is to be confirmed by other studies. It could be explained by saturation of the protective mechanisms against alkylating action of this product. This study prompted us to discuss the epidemiological difficulties in studies of cataracts.

  14. Quantification of plume opacity by digital photography.

    PubMed

    Du, Ke; Rood, Mark J; Kim, Byung J; Kemme, Michael R; Franek, Bill; Mattison, Kevin

    2007-02-01

    The United States Environmental Protection Agency (USEPA) developed Method 9 to describe how plume opacity can be quantified by humans. However, use of observations by humans introduces subjectivity, and is expensive due to semiannual certification requirements of the observers. The Digital Opacity Method (DOM) was developed to quantify plume opacity at lower cost, with improved objectivity, and to provide a digital record. Photographs of plumes were taken with a calibrated digital camera under specified conditions. Pixel values from those photographs were then interpreted to quantify the plume's opacity using a contrast model and a transmission model. The contrast model determines plume opacity based on pixel values that are related to the change in contrast between two backgrounds that are located behind and next to the plume. The transmission model determines the plume's opacity based on pixel values that are related to radiances from the plume and its background. DOM was field tested with a smoke generator. The individual and average opacity errors of DOM were within the USEPA Method 9 acceptable error limits for both field campaigns. Such results are encouraging and support the use of DOM as an alternative to Method 9.

  15. Age-dependent denaturation of enzymes in the human lens: a paradigm for organismic aging?

    PubMed

    Zhu, Xiangjia; Korlimbinis, Anastasia; Truscott, Roger J W

    2010-10-01

    Little is known about the rate of denaturation of proteins within the human body. To monitor this decline, human eye lenses were dissected into discrete regions that were formed at different stages of life and assayed for activity of lactate dehydrogenase (LDH) and a particularly stable enzyme, glutathione reductase (GR). Activity was highest for both enzymes in the most recently synthesized outer part of the lens, decreased further into the lens, and, for LDH, was barely detectable in nuclear regions that consist of proteins that were synthesized in utero. For LDH, 95% of total lens activity was found in the outer half of the adult lens at all ages. Activity was unchanged in the outermost part of the lens as a function of age, suggesting that the ability of humans to synthesize the two enzymes is not impaired, even up to the tenth decade. After age of 40, LDH activity declined steadily in the interior of the lens at the rate of 8.3% per decade. GR activity diminished more slowly, and western blotting indicated that both denaturation of the enzyme and truncation were responsible. These data support the view that few, if any, metabolic pathways remain in the center of older lenses. Exposure of the enzymes to physiological pH and temperature over a period of decades is presumably sufficient to cause denaturation. The center of older human lenses is a unique environment in which the accumulation of untoward posttranslational modifications to proteins can be studied in the absence of significant enzymatic amelioration.

  16. Tropomyosin 2 heterozygous knockout in mice using CRISPR-Cas9 system displays the inhibition of injury-induced epithelial-mesenchymal transition, and lens opacity

    PubMed Central

    Shibata, Teppei; Shibata, Shinsuke; Ishigaki, Yasuhito; Kiyokawa, Etsuko; Ikawa, Masahito; Singh, Dhirendra P.; Sasaki, Hiroshi; Kubo, Eri

    2018-01-01

    The process of epithelial–mesenchymal transition (EMT) of lens epithelial cells (LECs) after cataract surgery contributes to tissue fibrosis, wound healing and lens regeneration via a mechanism not yet fully understood. Here, we show that tropomyosin 2 (Tpm2) plays a critical role in wound healing and lens aging. Posterior capsular opacification (PCO) after lens extraction surgery was accompanied by elevated expression of Tpm2. Tpm2 heterozygous knockout mice, generated via the clustered regularly interspaced short palindromic repeat/ Cas9 (CRISPR/Cas9) system showed promoted progression of cataract with age. Further, injury-induced EMT of the mouse lens epithelium, as evaluated histologically and by the expression patterns of Tpm1 and Tpm2, was attenuated in the absence of Tpm2. In conclusion, Tpm2 may be important in maintaining lens physiology and morphology. However, Tpm2 is involved in the progression of EMT during the wound healing process of mouse LECs, suggesting that inhibition of Tpm2 may suppress PCO. PMID:29510160

  17. Telomere Attrition in Human Lens Epithelial Cells Associated with Oxidative Stress Provide a New Therapeutic Target for the Treatment, Dissolving and Prevention of Cataract with N-Acetylcarnosine Lubricant Eye Drops. Kinetic, Pharmacological and Activity-Dependent Separation of Therapeutic Targeting: Transcorneal Penetration and Delivery of L-Carnosine in the Aqueous Humor and Hormone-Like Hypothalamic Antiaging Effects of the Instilled Ophthalmic Drug Through a Safe Eye Medication Technique.

    PubMed

    Babizhayev, Mark A; Yegorov, Yegor E

    2016-01-01

    Visual impairment broadly impacts the ability of affected people to maintain their function and to remain independent during their daily occupations as they grow older. Visual impairment affects survival of older patients, quality of life, can affect a person's self-ranking of health, may be associated with social and functional decline, use of community support services, depression, falls, nursing home placement, and increased mortality. It has been hypothesized that senile cataract may serve as a marker for generalised tissue aging, since structural changes occurring in the proteins of the lens during cataract formation are similar to those which occur elsewhere as part of the aging process. The published analysis revealed a strong age-dependent relationship between undergoing cataract surgery and subsequent mortality. Nuclear opacity, particularly severe nuclear opacity, and mixed opacities with nuclear were significant predictors of mortality independent of body mass index, comorbid conditions, smoking, age, race, and sex. The lens opacity status is considered as an independent predictor of 2-year mortality, an association that could not be explained by potential confounders. Telomeres have become important biomarkers for aging as well as for oxidative stress-related disease. The lens epithelium is especially vulnerable to oxidative stress. Oxidative damage to the cuboidal epithelial cells on the anterior surface of the lens mediated by reactive oxygen species and phospholipid hydroperoxides can precede and contribute to human lens cataract formation. The erosion and shortening of telomeres in human lens epithelial cells in the lack of telomerase activity has been recognized as a primary cause of premature lens senescence phenotype that trigger human cataractogenesis. In this study we aimed to be focused on research defining the mechanisms that underlie linkages among telomere attrition in human lens epithelial cells associated with oxidative stress, biology of

  18. Application of the ELDO approach to assess cumulative eye lens doses for interventional cardiologists.

    PubMed

    Farah, J; Struelens, L; Auvinen, A; Jacob, S; Koukorava, C; Schnelzer, M; Vanhavere, F; Clairand, I

    2015-04-01

    In preparation of a large European epidemiological study on the relation between eye lens dose and the occurrence of lens opacities, the European ELDO project focused on the development of practical methods to estimate retrospectively cumulative eye lens dose for interventional medical professionals exposed to radiation. The present paper applies one of the ELDO approaches, correlating eye lens dose to whole-body doses, to assess cumulative eye lens dose for 14 different Finnish interventional cardiologists for whom annual whole-body dose records were available for their entire working period. The estimated cumulative left and right eye lens dose ranged from 8 to 264 mSv and 6 to 225 mSv, respectively. In addition, calculations showed annual eye lens doses sometimes exceeding the new ICRP annual limit of 20 mSv. The work also highlights the large uncertainties associated with the application of such an approach proving the need for dedicated dosimetry systems in the routine monitoring of the eye lens dose. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  19. Transient anterior subcapsular vacuolar change of the crystalline lens in patients after posterior chamber phakic intraocular lens implantation.

    PubMed

    Chung, Jin Kwon; Shin, Jin Hee; Lee, Sung Jin

    2013-10-25

    We present two cases of transient vacuolar changes in the anterior subcapsular space of the crystalline lens in patients after posterior chamber phakic intraocular lens implantation. Implantable collamer lenses (ICL) were implanted in healthy myopic patients. Vacuolar changes developed just after the irrigating procedure through the narrow space between the ICL and the crystalline lens. Slit-lamp examinations and spectral domain optical coherence tomography showed bleb-like lesions in the anterior subcapsular space of one eye in each case, though the lesions gradually improved without visual deterioration. Consequently, the lesions turned into a few anterior subcapsular small faint opacities. Direct irrigation of the narrow space confined by the ICL and the crystalline lens is at risk for the development of vacuolar changes in the crystalline lens. The observed spontaneous reversal indicates that surgeons should not rush to surgical intervention but rather opt for close follow over several weeks.

  20. Treatment of contact lens related dry eye with antibacterial honey.

    PubMed

    Wong, Daniel; Albietz, Julie M; Tran, Huan; Du Toit, Cimonette; Li, Anita Hui; Yun, Tina; Han, Jee; Schmid, Katrina L

    2017-12-01

    Contact lens induced dry eye affects approximately 50% of contact lens wearers. The aim was to assess the effects of Manuka (Leptospermum sp.) honey eye drops (Optimel, Melcare, Australia) on dry eye in contact lens wearers. The safety of the honey eye drops in contact lens wear and contact lens wearers' compliance were also evaluated. Prospective, randomised, cross over study, examiner masked, pilot treatment trial. Twenty-four participants aged 20 to 55 years with contact lens related dry eye were recruited and randomised to two treatment groups; 20 completed the study. One group used Optimel eye drops twice a day for two weeks followed by conventional lubricant (Systane Ultra, Alcon) therapy for two weeks; the other group completed the treatments in the reverse order. Before and after each treatment dry eye symptomology, ocular surface inflammation, and tear quantity and quality were assessed. Participants completed a daily log detailing their usage of treatments and any issues. Dry eye symptoms improved significantly after Optimel treatment. Patients with more severe symptoms at baseline showed a greater improvement in symptoms. No significant differences were observed in the objective signs of dry eye; presumably because of the short treatment duration. Seventy-five% of contact lens wearers reported good adherence to Optimel treatment and 95% reported no issues using this product. Optimel Eye Drops reduce the symptoms of dry eye in contact lens wearers and are safe to use. A longer treatment period to assess the effect on clinical signs of dry eye is required. Copyright © 2017 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  1. A Protective Eye Shield for Prevention of Media Opacities during Small Animal Ocular Imaging

    PubMed Central

    Bell, Brent A.; Kaul, Charles; Hollyfield, Joe G.

    2014-01-01

    Optical coherence tomography (OCT), scanning laser ophthalmoscopy (SLO) and other non-invasive imaging techniques are increasingly used in eye research to document disease-related changes in rodent eyes. Corneal dehydration is a major contributor to the formation of ocular opacities that can limit the repeated application of these techniques to individual animals. General anesthesia is usually required for imaging, which is accompanied by the loss of the blink reflex. As a consequence, the tear film cannot be maintained, drying occurs and the cornea becomes dehydrated. Without supplemental hydration, structural damage to the cornea quickly follows. Soon thereafter, anterior lens opacities can also develop. Collectively these changes ultimately compromise image quality, especially for studies involving repeated use of the same animal over several weeks or months. To minimize these changes, a protective shield was designed for mice and rats that prevent ocular dehydration during anesthesia. The eye shield, along with a semi-viscous ophthalmic solution, is placed over the corneas as soon as the anesthesia immobilizes the animal. Eye shields are removed for only the brief periods required for imaging and then reapplied before the fellow eye is examined. As a result, the corneal surface of each eye is exposed only for the time required for imaging. The device and detailed methods described here minimize the corneal and lens changes associated with ocular surface desiccation. When these methods are used consistently, high quality images can be obtained repeatedly from individual animals. PMID:25245081

  2. Automated lamellar therapeutic keratoplasty with fibrin adhesive in the treatment of anterior corneal opacities.

    PubMed

    Hashemi, Hassan; Dadgostar, Alhan

    2011-06-01

    To assess the visual outcome of using fibrin adhesive in automated lamellar therapeutic keratoplasty with a microkeratome in the treatment of anterior corneal opacities. In this prospective noncomparative clinical trial, surgery was done on 10 eyes belonging to 9 patients with anterior stromal opacity (macular dystrophy, spheroidal degeneration, scarring because of advanced recurrent pterygium, refractive surgery, or trauma). Depending on the depth of the opacity, a 130- or 250-μm flap was removed from the recipient cornea using a microkeratome. Then, a thin layer of fibrin adhesive was spread over the bed, and a lenticule with the same thickness, created from the donor cornea, was positioned in place. After allowing the glue to set for about 5 minutes, a bandage contact lens was placed over the cornea, which was removed 7-10 days postoperatively. All corneas healed properly, and none required suturing or reoperation. During the follow-up period, no inflammation or rejection was observed. The donor cornea and the donor-recipient interface remained clear in all cases. The mean of best contact lens-corrected visual acuity improved from 1.14 ± 0.53 to 0.51 ± 0.23 in the logarithm of the minimum angle of resolution scale. The fibrin glue can provide safe and effective attachment needed in automated lamellar therapeutic keratectomy and obviates the need for suturing. However, it requires improvement for easier and safer use in ophthalmology.

  3. Smoking, socioeconomic factors, and age-related cataract: The Singapore Malay Eye study.

    PubMed

    Wu, Renyi; Wang, Jie Jin; Mitchell, Paul; Lamoureux, Ecosse L; Zheng, Yingfeng; Rochtchina, Elena; Tan, Ava G; Wong, Tien Yin

    2010-08-01

    To describe the relationship of smoking, sex, and socioeconomic factors with age-related cataract in Malay adults in Singapore. In a population-based study, 3280 Malay individuals aged 40 to 80 years participated (78.7% response rate). All had interviews, systemic examination, and laboratory investigations. Lens opacity was graded from slitlamp and retroillumination photographs using the Wisconsin Cataract Grading System. Smoking-cataract associations were compared with the Blue Mountains Eye Study in Australia. Of 2927 participants (89.2%) with gradable lens photographs, 1338 (45.7%) had cataract. After adjusting for age, sex, body mass index, hypertension, and diabetes, current smokers had a higher prevalence of nuclear cataract (odds ratio [OR], 2.06; 95% confidence interval [CI], 1.46-2.98), cortical cataract (OR, 1.33; 95% CI, 1.02-1.74), posterior subcapsular cataract (OR, 1.39; 95% CI, 1.02-1.91), or any cataract (OR, 1.48; 95% CI, 1.10-1.99). These associations were not seen in the Blue Mountains Eye Study. Primary or lower education (OR, 1.67; 95% CI, 1.06-2.64) and low monthly income (OR, 1.43; 95% CI, 1.09-1.87) were both associated with nuclear cataract, while small-sized public housing was associated with posterior subcapsular cataract (OR, 1.70; 95% CI, 1.28-2.25). Among men, 43.5% currently smoked compared with only 3.2% of women. The population attributable risk of nuclear cataract due to smoking was estimated to be 17.6% in men. Smoking and indicators of low socioeconomic status were associated with cataract in Malay persons, with 1 in 6 nuclear cataract cases in men attributable to smoking. Smoking-cataract associations were stronger in Malay than in white persons.

  4. TU-E-201-03: Eye Lens Dosimetry in Radiotherapy Using Contact Lens-Shaped Applicator

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Park, J.

    Madan M. Rehani, Massachusetts General Hospital and Harvard Medical School, Boston Methods for Eye Lens Dosimetry and Studies On Lens Opacities with Interventionalists Radiation induced cataract is a major threat among staff working in interventional suites. Nearly 16 million interventional procedures are performed annually in USA. Recent studies by the principal investigator’s group, primarily among interventional cardiologists, on behalf of the International Atomic Energy Agency, show posterior subcapsular (PSC) changes in the eye lens in 38–53% of main operators and 21–45% of support staff. These changes have potential to lead to cataract in future years, as per information from A-Bombmore » survivors. The International Commission on Radiological Protection has reduced dose limit for staff by a factor of 7.5 (from 150 mSv/y to 20 mSv/y). With increasing emphasis on radiation induced cataracts and reduction in threshold dose for eye lens, there is a need to implement strategies for estimating eye lens dose. Unfortunately eye lens dosimetry is at infancy when it comes to routine application. Various approaches are being tried namely direct measurement using active or passive dosimeters kept close to eyes, retrospective estimations and lastly correlating patient dose in interventional procedures with staff eye dose. The talk will review all approaches available and ongoing active research in this area, as well as data from surveys done in Europe on status of eye dose monitoring in interventional radiology and nuclear medicine. The talk will provide update on how good is Hp(10) against Hp(3), estimations from CTDI values, Monte Carlo based simulations and current status of eye lens dosimetry in USA and Europe. The cataract risk among patients is in CT examinations of the head. Since radiation induced cataract predominantly occurs in posterior sub-capsular (PSC) region and is thus distinguishable from age or drug related cataracts and is also preventable

  5. Lens protein composition, glycation and high molecular weight aggregation in aging rats.

    PubMed

    Swamy, M S; Abraham, E C

    1987-10-01

    Because of minimal or no turnover, lens proteins are subjected to substantial post-translational modifications which in turn disrupt lens architecture and change the optical properties leading to senile cataract formation. Progressive glycation is believed to have the potential to initiate the changes that are conducive to lens opacification. Fisher 344 rats were systematically followed from juvenile to older and aged phases of their life to study the relationship between lens glycation and high molecular weight (HMW) aggregate formation as well as quantitative and qualitative changes in lens crystallins. Levels of glycated proteins were quantified by affinity chromatography. Changes in lens crystallin composition and HMW aggregate formation were monitored by molecular sieve HPLC, further confirmed by SDS-PAGE and IEF techniques. As the age advances HMW and insoluble proteins increase with a concomitant disappearance of gamma-crystallins from soluble fraction. This disappearance of gamma-crystallins coincided with increased glycation (approximately 2-fold higher in insoluble fraction) and decreased sulfhydryl groups from soluble fraction. It appears that lens protein glycation, disappearance of gamma-crystallins and sulfhydryls from soluble fraction and increase of insoluble fraction and HMW aggregate are interrelated.

  6. Comparative pulsation calculations with OP and OPAL opacities

    NASA Technical Reports Server (NTRS)

    Kanbur, Shashi M.; Simon, Norman R.

    1994-01-01

    Comparative linear nonadiabatic pulsation calculations are presented using the OPAL and Opacity Project opacities. The two sets of opacities include effects due to intermediate coupling and fine structure as well as new abundances. We used two mass luminosity (M-L) relations, one standard (BIT), and one employing substantial convective core overshoot (COV). The two sets of opacities cannot be differentiated on the basis of the stellar pulsation calculations presented here. The BIT relation can model the beat and bump Cepheids with masses between 4 and 7 solar mass, while if the overshoot relation is used, masses between 2 and 6 solar mass are required. In the RR Lyrae regime, we find the inferred masses of globular cluster RRd stars to be little influenced by the choice of OPAL or OP. Finally, the limited modeling we have done is not able to constrain the Cepheid M-L relation based upon period ratios observed in the beat and bump stars.

  7. The Effect of Age on Compensation for a Negative Lens and Recovery from Lens-induced Myopia in Tree Shrews (Tupaia glis belangeri)

    PubMed Central

    Norton, Thomas T.; Amedo, Angela O.; Siegwart, John T.

    2010-01-01

    We examined in tree shrews the effect of age on the development of, and recovery from, myopia induced with a negative lens. Starting at 11, 16, 24, 35 or 48 days after natural eye-opening (days of visual experience [VE]), juvenile tree shrews (n = 5 per group) wore a monocular −5 D lens for 11 days. A long-term lens-wear group (n=6) began treatment at 16 days of VE and wore the lens for 30 days. A young adult group (n = 5) began to wear a −5 D lens between 93 and 107 days of VE (mean ± SD, 100 ± 6 days of VE) and wore the lens for 29 to 54 days (mean ± SD, 41.8 ± 9.8 days). The recovery phase in all groups was started by discontinuing −5 D lens wear. Contralateral control eyes in the three youngest groups were compared with a group of age-matched normal eyes and showed a small (<1 D), transient myopic shift. The amount of myopia that developed during lens wear was measured as the difference between the treated and control eye refractions. After 11 days of lens wear, the induced myopia was similar for the four younger groups (near full compensation: 11 day, −5.1 ± 0.4 D; 16 day, −4.7 ± 0.3 D, 24 day, −4.9 ± 0.4 D; 35 day, −4.0 ± 0.02) and slightly less in the oldest juvenile group (48 day, −3.3 ± 0.5 D). The young adult animals developed −4.8 ± 0.3 D of myopia after a longer lens-wear period. The rate of compensation (D/day) was high in the 4 youngest groups and decreased in the 48-day and young adult groups. The refractions of the long-term lens-wear juvenile group remained stable after compensating for the −5 D lens. During recovery, all animals in the youngest group recovered fully (< 1 D residual myopia) within seven days. Examples of both rapid (< 10 days) and slow recovery (> 12 days) occurred in all age groups except the youngest. Every animal showed more rapid recovery (higher recovery slope) in the first 4 days than afterward. One animal showed extremely slow recovery. Based on the time-course of myopia development observed in

  8. The molecular chaperone alphaA-crystallin enhances lens epithelial cell growth and resistance to UVA stress.

    PubMed

    Andley, U P; Song, Z; Wawrousek, E F; Bassnett, S

    1998-11-20

    alphaA-Crystallin (alphaA) is a member of the small heat shock protein (sHSP) family and has the ability to prevent denatured proteins from aggregating in vitro. Lens epithelial cells express relatively low levels of alphaA, but in differentiated fiber cells, alphaA is the most abundant soluble protein. The lenses of alphaA-knock-out mice develop opacities at an early age, implying a critical role for alphaA in the maintenance of fiber cell transparency. However, the function of alpha-crystallin in the lens epithelium is unknown. To investigate the physiological function of alphaA in lens epithelial cells, we used the following two systems: alphaA knock-out (alphaA(-/-)) mouse lens epithelial cells and human lens epithelial cells that overexpress alphaA. The growth rate of alphaA(-/-) mouse lens epithelial cells was reduced by 50% compared with wild type cells. Cell cycle kinetics, measured by fluorescence-activated cell sorter analysis of propidium iodide-stained cells, indicated a relative deficiency of alphaA(-/-) cells in the G2/M phases. Exposure of mouse lens epithelial cells to physiological levels of UVA resulted in an increase in the number of apoptotic cells in the cultures. Four hours after irradiation the fraction of apoptotic cells in the alphaA(-/-) cultures was increased 40-fold over wild type. In cells lacking alphaA, UVA exposure modified F-actin, but actin was protected in cells expressing alphaA. Stably transfected cell lines overexpressing human alphaA were generated by transfecting extended life span human lens epithelial cells with the mammalian expression vector construct pCI-neoalphaA. Cells overexpressing alphaA were resistant to UVA stress, as determined by clonogenic survival. alphaA remained cytoplasmic after exposure to either UVA or thermal stress indicating that, unlike other sHSPs, the protective effect of alphaA was not associated with its relocalization to the nucleus. These results indicate that alphaA has important cellular

  9. SOLAR OPACITY CALCULATIONS USING THE SUPER-TRANSITION-ARRAY METHOD

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Krief, M.; Feigel, A.; Gazit, D., E-mail: menahem.krief@mail.huji.ac.il

    A new opacity model has been developed based on the Super-Transition-Array (STA) method for the calculation of monochromatic opacities of plasmas in local thermodynamic equilibrium. The atomic code, named STAR (STA-Revised), is described and used to calculate spectral opacities for a solar model implementing the recent AGSS09 composition. Calculations are carried out throughout the solar radiative zone. The relative contributions of different chemical elements and atomic processes to the total Rosseland mean opacity are analyzed in detail. Monochromatic opacities and charge-state distributions are compared with the widely used Opacity Project (OP) code, for several elements near the radiation–convection interface. STARmore » Rosseland opacities for the solar mixture show a very good agreement with OP and the OPAL opacity code throughout the radiation zone. Finally, an explicit STA calculation was performed of the full AGSS09 photospheric mixture, including all heavy metals. It was shown that, due to their extremely low abundance, and despite being very good photon absorbers, the heavy elements do not affect the Rosseland opacity.« less

  10. Electron microscopic examination of the anterior lens capsule in a case of Alport's syndrome.

    PubMed

    Citirik, Mehmet; Batman, Cosar; Men, Gamze; Tuncel, Murvet; Zilelioglu, Orhan

    2007-09-01

    To report a case of Alport's syndrome and to present electronmicroscopic examination findings of the anterior lens capsule of this patient. A 21-year-old man was referred for low visual acuity and retinal pigment epithelial changes in the left eye. The patient and his relatives underwent detailed ophthalmological examination, including electrophysiological testing. The patient also underwent electronmicroscopic examination of the anterior lens capsule. His visual acuity was 6/18 OD and 6/15 OS. Anterior lenticonus and subcapsular opacities were observed in the left eye. Cataract extraction by phacoemulsification with intraocular lens implantation was performed for his poor visual performance. During the capsulorhexis, the remarkably thin and fragile anterior capsule was noted and removed. Ultrastructural analysis of the anterior lens capsule showed a thinner central zone compared with the periphery. The course of Alport's syndrome can be ameliorated by early diagnosis. Therefore, the ophthalmological examination of a patient with anterior lenticonus must be combined with a detailed medical evaluation. Ultrastructural analysis of the lens capsule can support the diagnosis of Alport's syndrome.

  11. Age-dependent Fourier model of the shape of the isolated ex vivo human crystalline lens.

    PubMed

    Urs, Raksha; Ho, Arthur; Manns, Fabrice; Parel, Jean-Marie

    2010-06-01

    To develop an age-dependent mathematical model of the zero-order shape of the isolated ex vivo human crystalline lens, using one mathematical function, that can be subsequently used to facilitate the development of other models for specific purposes such as optical modeling and analytical and numerical modeling of the lens. Profiles of whole isolated human lenses (n=30) aged 20-69, were measured from shadow-photogrammetric images. The profiles were fit to a 10th-order Fourier series consisting of cosine functions in polar-co-ordinate system that included terms for tilt and decentration. The profiles were corrected using these terms and processed in two ways. In the first, each lens was fit to a 10th-order Fourier series to obtain thickness and diameter, while in the second, all lenses were simultaneously fit to a Fourier series equation that explicitly include linear terms for age to develop an age-dependent mathematical model for the whole lens shape. Thickness and diameter obtained from Fourier series fits exhibited high correlation with manual measurements made from shadow-photogrammetric images. The root-mean-squared-error of the age-dependent fit was 205 microm. The age-dependent equations provide a reliable lens model for ages 20-60 years. The contour of the whole human crystalline lens can be modeled with a Fourier series. Shape obtained from the age-dependent model described in this paper can be used to facilitate the development of other models for specific purposes such as optical modeling and analytical and numerical modeling of the lens. Copyright (c) 2010 Elsevier Ltd. All rights reserved.

  12. Alterations in lenticular proteins during ageing and selenite-induced cataractogenesis in Wistar rats

    PubMed Central

    Sakthivel, Muniyan; Elanchezhian, Rajan; Thomas, Philip A.

    2010-01-01

    Purpose To determine putative alterations in the major lenticular proteins in Wistar rats of different ages and to compare these alterations with those occurring in rats with selenite-induced cataract. Methods Lenticular transparency was determined by morphological examination using slit-lamp biomicroscopy. Alterations in lenticular protein were determined by sodium dodecyl sulfate-PAGE (SDS–PAGE) and confirmed immunologically by western blot. Results Morphological examination did not reveal observable opacities in the lenses of the rats of different age groups; however, dense nuclear opacities were noted in lenses of rats in the selenite-cataract group. Western blot assays revealed age-related changes in soluble and urea-soluble lenticular proteins. Decreased αA- and βB1-crystallins in the soluble fraction and aggregation of αA-crystallin, in addition to the degraded fragment of βB1-crystallin, in the urea-soluble fraction appeared to occur in relation to increasing age of the rats from which the lenses were taken; similarly, cytoskeletal proteins appeared to decline with increasing age. The lenses from rats in the selenite-cataract group exhibited similar changes, except that there was also high molecular weight aggregation of αA-crystallin. Conclusions The results of this study suggest that there is loss, as well as aggregation, of αA-crystallin in the aging rat lens, although there is no accompanying loss of lenticular transparency. PMID:20300567

  13. Alterations in lenticular proteins during ageing and selenite-induced cataractogenesis in Wistar rats.

    PubMed

    Sakthivel, Muniyan; Elanchezhian, Rajan; Thomas, Philip A; Geraldine, Pitchairaj

    2010-03-16

    To determine putative alterations in the major lenticular proteins in Wistar rats of different ages and to compare these alterations with those occurring in rats with selenite-induced cataract. Lenticular transparency was determined by morphological examination using slit-lamp biomicroscopy. Alterations in lenticular protein were determined by sodium dodecyl sulfate-PAGE (SDS-PAGE) and confirmed immunologically by western blot. Morphological examination did not reveal observable opacities in the lenses of the rats of different age groups; however, dense nuclear opacities were noted in lenses of rats in the selenite-cataract group. Western blot assays revealed age-related changes in soluble and urea-soluble lenticular proteins. Decreased alphaA- and betaB1-crystallins in the soluble fraction and aggregation of alphaA-crystallin, in addition to the degraded fragment of betaB1-crystallin, in the urea-soluble fraction appeared to occur in relation to increasing age of the rats from which the lenses were taken; similarly, cytoskeletal proteins appeared to decline with increasing age. The lenses from rats in the selenite-cataract group exhibited similar changes, except that there was also high molecular weight aggregation of alphaA-crystallin. The results of this study suggest that there is loss, as well as aggregation, of alphaA-crystallin in the aging rat lens, although there is no accompanying loss of lenticular transparency.

  14. Age-dependence of the average and equivalent refractive indices of the crystalline lens

    PubMed Central

    Charman, W. Neil; Atchison, David A.

    2013-01-01

    Lens average and equivalent refractive indices are required for purposes such as lens thickness estimation and optical modeling. We modeled the refractive index gradient as a power function of the normalized distance from lens center. Average index along the lens axis was estimated by integration. Equivalent index was estimated by raytracing through a model eye to establish ocular refraction, and then backward raytracing to determine the constant refractive index yielding the same refraction. Assuming center and edge indices remained constant with age, at 1.415 and 1.37 respectively, average axial refractive index increased (1.408 to 1.411) and equivalent index decreased (1.425 to 1.420) with age increase from 20 to 70 years. These values agree well with experimental estimates based on different techniques, although the latter show considerable scatter. The simple model of index gradient gives reasonable estimates of average and equivalent lens indices, although refinements in modeling and measurements are required. PMID:24466474

  15. Development of cataract and corneal opacity in mice due to radon exposure

    NASA Astrophysics Data System (ADS)

    Abdelkawi, S. A.; Abo-Elmagd, M.; Soliman, H. A.

    This work investigates the radiation damage on the eye of albino mice exposed to effective radon doses ranging from 20.92 to 83.68 mSv. These doses were taken over 2-8 weeks using a radon chamber constructed by the National Institute for Standard (Egypt). The guidance on the quality assurance program for radon measurements was followed. Therefore, the estimated doses received by the laboratory animals meet the requirements of national standardE The refractive index(RI) and protein concentration were measured for soluble proteins of both corneas and lenses. In addition, the sodium dodecyle sulfate polyacrylamide gel electrophoresis (SDSPAGE) technique was used. The results show increasing of the RI of both cornea and lens proteins and decreasing in total protein concentration of exposed animals. These results were accompanied with changes in the SDSPAGE profile for both cornea and lens. Therefore, radon exposure produces substantial hazards to the cornea and lens of experimental animals and has a crucial role in the development of cataract and corneal opacity.

  16. Significance of Interactions of Low Molecular Weight Crystallin Fragments in Lens Aging and Cataract Formation*

    PubMed Central

    Santhoshkumar, Puttur; Udupa, Padmanabha; Murugesan, Raju; Sharma, K. Krishna

    2008-01-01

    Analysis of aged and cataract lenses shows the presence of increased amounts of crystallin fragments in the high molecular weight aggregates of water-soluble and water-insoluble fractions. However, the significance of accumulation and interaction of low molecular weight crystallin fragments in aging and cataract development is not clearly understood. In this study, 23 low molecular mass (<3.5-kDa) peptides in the urea-soluble fractions of young, aged, and aged cataract human lenses were identified by mass spectroscopy. Two peptides, αB-(1–18) (MDIAIHHPWIRRPFFPFH) and βA3/A1-(59–74) (SD(N)AYHIERLMSFRPIC), present in aged and cataract lens but not young lens, and a third peptide, γS-(167–178) (SPAVQSFRRIVE) present in all three lens groups were synthesized to study the effects of interaction of these peptides with intact α-, β-, and γ-crystallins and alcohol dehydrogenase, a protein used in aggregation studies. Interaction of αB-(1–18) and βA3/A1-(59–74) peptides increased the scattering of light by β- and γ-crystallin and alcohol dehydrogenase. The ability of α-crystallin subunits to function as molecular chaperones was significantly reduced by interaction with αB-(1–18) and βA3/A1-(59–74) peptides, whereas γS peptide had no effect on chaperone-like activity of α-crystallin. The βA3/A1-(59–74 peptide caused a 5.64-fold increase in αB-crystallin oligomeric mass and partial precipitation. Replacing hydrophobic residues in αB-(1–18) and βA3/A1-(59–74) peptides abolished their ability to induce crystallin aggregation and light scattering. Our study suggests that interaction of crystallin-derived peptides with intact crystallins could be a key event in age-related protein aggregation in lens and cataractogenesis. PMID:18227073

  17. Molecular Genetics of Cataract

    PubMed Central

    Shiels, Alan; Hejtmancik, J. Fielding

    2017-01-01

    Lens opacities or cataract(s) represent a universally important cause of visual impairment and blindness. Typically, cataract is acquired with aging as a complex disorder involving environmental and genetic risk factors. Cataract may also be inherited with an early onset either in association with other ocular and/or systemic abnormalities or as an isolated lens phenotype. Here we briefly review recent advances in gene discovery for inherited and age-related forms of cataract that are providing new insights into lens development and aging. PMID:26310156

  18. Lanthanide/Actinide Opacities

    NASA Astrophysics Data System (ADS)

    Hungerford, Aimee; Fontes, Christopher J.

    2018-06-01

    Gravitational wave observations benefit from accompanying electromagnetic signals in order to accurately determine the sky positions of the sources. The ejecta of neutron star mergers are expected to produce such electromagnetic transients, called macronovae (e.g. the recent and unprecedented observation of GW170817). Characteristics of the ejecta include large velocity gradients and the presence of heavy r-process elements, which pose significant challenges to the accurate calculation of radiative opacities and radiation transport. Opacities include a dense forest of bound-bound features arising from near-neutral lanthanide and actinide elements. Here we present an overview of current theoretical opacity determinations that are used by neutron star merger light curve modelers. We will touch on atomic physics and plasma modeling codes that are used to generate these opacities, as well as the limited body of laboratory experiments that may serve as points of validation for these complex atomic physics calculations.

  19. Epigenetic Regulation of Werner Syndrome Gene in Age-Related Cataract

    PubMed Central

    Guan, Huaijin

    2015-01-01

    Purpose. To examine the promoter methylation and histone modification of WRN (Werner syndrome gene), a DNA repair gene, and their relationship with the gene expression in age-related cataract (ARC) lens. Methods. We collected the lenses after cataract surgery from 117ARC patients and 39 age-matched non-ARC. WRN expression, DNA methylation and histone modification around the CpG island were assessed. The methylation status of Human-lens-epithelium cell (HLEB-3) was chemically altered to observe the relationship between methylation and expression of WRN. Results. The WRN expression was significantly decreased in the ARC anterior lens capsules comparing with the control. The CpG island of WRN promoter in the ARC anterior lens capsules displayed hypermethylation comparing with the controls. The WRN promoter was almost fully methylated in the cortex of ARC and control lens. Acetylated H3 was lower while methylated H3-K9 was higher in ARC anterior lens capsules than that of the controls. The expression of WRN in HLEB-3 increased after demethylation of the cells. Conclusions. A hypermethylation in WRN promoter and altered histone modification in anterior lens capsules might contribute to the ARC mechanism. The data suggest an association of altered DNA repair capability in lens with ARC pathogenesis. PMID:26509079

  20. Higher-order aberrations of lenticular opacities.

    PubMed

    Sachdev, Nisha; Ormonde, Susan E; Sherwin, Trevor; McGhee, Charles N J

    2004-08-01

    spherical aberration compared to eyes without opacities. Both types of lenticular opacities also induced a higher amount of tetrafoil. This could explain the significant visual symptoms in patients with early cataract and relatively good high-contrast Snellen acuity.

  1. Mutations and mechanisms in congenital and age-related cataracts

    PubMed Central

    Shiels, Alan; Hejtmancik, J. Fielding

    2017-01-01

    The crystalline lens plays an important role in the refractive vision of vertebrates by facilitating variable fine focusing of light onto the retina. Loss of lens transparency, or cataract, is a frequently acquired cause of visual impairment in adults and may also present during childhood. Genetic studies have identified mutations in over 30 causative genes for congenital or other early-onset forms of cataract as well as several gene variants associated with age-related cataract. However, the pathogenic mechanisms resulting from genetic determinants of cataract are only just beginning to be understood. Here, we briefly summarize current concepts pointing to differences in the molecular mechanisms underlying congenital and age-related forms of cataract. PMID:27334249

  2. Citation parameters of contact lens-related articles published in the ophthalmic literature.

    PubMed

    Cardona, Genís; Sanz, Joan P

    2014-09-01

    This study aimed at exploring the citation parameters of contact lenses articles published in the Ophthalmology thematic category of the Journal Citation Reports (JCR). The Thompson Reuters Web of Science database was accessed to record bibliometric information and citation parameters of all journals listed under the Ophthalmology area of the 2011 JCR edition, including the journals with main publication interests in the contact lens field. In addition, the same database was used to unveil all contact lens-related articles published in 2011 in the same thematic area, whereupon differences in citation parameters between those articles published in contact lens and non-contact lens-related journals were explored. Significant differences in some bibliometric indicators such as half-life and overall citation count were found between contact lens-related journals (shorter half-life and fewer citations) and the median values for the Ophthalmology thematic area of the JCR. Visual examination of all Ophthalmology journals uncovered a total of 156 contact lens-related articles, published in 28 different journals, with 27 articles each for Contact Lens & Anterior Eye, Eye & Contact Lens, and Optometry and Vision Science. Significant differences in citation parameters were encountered between those articles published in contact lens and non-contact lens source journals. These findings, which disclosed contact lenses to be a fertile area of research, may be of interest to researchers and institutions. Differences in bibliometric indicators are of relevance to avoid unwanted bias when conducting between- and within-discipline comparisons of articles, journals, and researchers.

  3. Thus Spake the OPAC User.

    ERIC Educational Resources Information Center

    Markey, Karen

    1983-01-01

    Findings of focused-group interviews conducted for OCLC study of library users and online public access catalogs (OPACs) indicate users like OPACs, have problems finding right subject heading, envision features to improve subject access, want access to more than books, and want OPACs to provide new services. Eight references are listed. (EJS)

  4. The ability of lens alpha crystallin to protect against heat-induced aggregation is age-dependent

    NASA Technical Reports Server (NTRS)

    Horwitz, J.; Emmons, T.; Takemoto, L.; Spooner, B. S. (Principal Investigator)

    1992-01-01

    Alpha crystallin was prepared from newborn and aged bovine lenses. SDS-PAGE and tryptic peptide mapping demonstrated that both preparations contained only the alpha-A and alpha-B chains, with no significant contamination of other crystallins. Compared with alpha crystallin from the aged lens, alpha crystallin from the newborn lens was much more effective in the inhibition of beta L crystallin denaturation and precipitation induced in vitro by heat. Together, these results demonstrate that during the aging process, the alpha crystallins lose their ability to protect against protein denaturation, consistent with the hypothesis that the alpha crystallins play an important role in the maintenance of protein native structure in the intact lens.

  5. Evidence of Highly Conserved β-Crystallin Disulfidome that Can be Mimicked by In Vitro Oxidation in Age-related Human Cataract and Glutathione Depleted Mouse Lens*

    PubMed Central

    Fan, Xingjun; Zhou, Sheng; Wang, Benlian; Hom, Grant; Guo, Minfei; Li, Binbin; Yang, Jing; Vaysburg, Dennis; Monnier, Vincent M

    2015-01-01

    Low glutathione levels are associated with crystallin oxidation in age-related nuclear cataract. To understand the role of cysteine residue oxidation, we used the novel approach of comparing human cataracts with glutathione-depleted LEGSKO mouse lenses for intra- versus intermolecular disulfide crosslinks using 2D-PAGE and proteomics, and then systematically identified in vivo and in vitro all disulfide forming sites using ICAT labeling method coupled with proteomics. Crystallins rich in intramolecular disulfides were abundant at young age in human and WT mouse lens but shifted to multimeric intermolecular disulfides at older age. The shift was ∼4x accelerated in LEGSKO lens. Most cysteine disulfides in β-crystallins (except βA4 in human) were highly conserved in mouse and human and could be generated by oxidation with H2O2, whereas γ-crystallin oxidation selectively affected γC23/42/79/80/154, γD42/33, and γS83/115/130 in human cataracts, and γB79/80/110, γD19/109, γF19/79, γE19, γS83/130, and γN26/128 in mouse. Analysis based on available crystal structure suggests that conformational changes are needed to expose Cys42, Cys79/80, Cys154 in γC; Cys42, Cys33 in γD, and Cys83, Cys115, and Cys130 in γS. In conclusion, the β-crystallin disulfidome is highly conserved in age-related nuclear cataract and LEGSKO mouse, and reproducible by in vitro oxidation, whereas some of the disulfide formation sites in γ-crystallins necessitate prior conformational changes. Overall, the LEGSKO mouse model is closely reminiscent of age-related nuclear cataract. PMID:26453637

  6. Vitamin C mediates chemical aging of lens crystallins by the Maillard reaction in a humanized mouse model

    PubMed Central

    Fan, Xingjun; Reneker, Lixing W.; Obrenovich, Mark E.; Strauch, Christopher; Cheng, Rongzhu; Jarvis, Simon M.; Ortwerth, Beryl J.; Monnier, Vincent M.

    2006-01-01

    Senile cataracts are associated with progressive oxidation, fragmentation, cross-linking, insolubilization, and yellow pigmentation of lens crystallins. We hypothesized that the Maillard reaction, which leads browning and aroma development during the baking of foods, would occur between the lens proteins and the highly reactive oxidation products of vitamin C. To test this hypothesis, we engineered a mouse that selectively overexpresses the human vitamin C transporter SVCT2 in the lens. Consequently, lenticular levels of vitamin C and its oxidation products were 5- to 15-fold elevated, resulting in a highly compressed aging process and accelerated formation of several protein-bound advanced Maillard reaction products identical with those of aging human lens proteins. These data strongly implicate vitamin C in lens crystallin aging and may serve as a model for protein aging in other tissues particularly rich in vitamin C, such as the hippocampal neurons and the adrenal gland. The hSVCT2 mouse is expected to facilitate the search for drugs that inhibit damage by vitamin C oxidation products. PMID:17075057

  7. Design of the opacity spectrometer for opacity measurements at the National Ignition Facility

    DOE PAGES

    Ross, P. W.; Heeter, R. F.; Ahmed, M. F.; ...

    2016-10-03

    Recent experiments at the Sandia National Laboratory Z facility have called into question models used in calculating opacity, of importance for modeling stellar interiors. An effort is being made to reproduce these results at the National Ignition Facility (NIF). These experiments require a new X-ray opacity spectrometer (OpSpec) spanning 540 eV–2100 eV with a resolving power E/ΔE > 700. The design of the OpSpec is presented. Photometric calculations based on expected opacity data are also presented in this paper. First use on NIF is expected in September 2016.

  8. Design of the opacity spectrometer for opacity measurements at the National Ignition Facility.

    PubMed

    Ross, P W; Heeter, R F; Ahmed, M F; Dodd, E; Huffman, E J; Liedahl, D A; King, J A; Opachich, Y P; Schneider, M B; Perry, T S

    2016-11-01

    Recent experiments at the Sandia National Laboratory Z facility have called into question models used in calculating opacity, of importance for modeling stellar interiors. An effort is being made to reproduce these results at the National Ignition Facility (NIF). These experiments require a new X-ray opacity spectrometer (OpSpec) spanning 540 eV-2100 eV with a resolving power E/ΔE > 700. The design of the OpSpec is presented. Photometric calculations based on expected opacity data are also presented. First use on NIF is expected in September 2016.

  9. Observational Constraints on Submillimeter Dust Opacity

    NASA Astrophysics Data System (ADS)

    Shirley, Yancy L.; Huard, Tracy L.; Pontoppidan, Klaus M.; Wilner, David J.; Stutz, Amelia M.; Bieging, John H.; Evans, Neal J., II

    2011-02-01

    Infrared extinction maps and submillimeter dust continuum maps are powerful probes of the density structure in the envelope of star-forming cores. We make a direct comparison between infrared and submillimeter dust continuum observations of the low-mass Class 0 core, B335, to constrain the ratio of submillimeter to infrared opacity (κsmm/κir) and the submillimeter opacity power-law index (κ vprop λ-β). Using the average value of theoretical dust opacity models at 2.2 μm, we constrain the dust opacity at 850 and 450 μm. Using new dust continuum models based upon the broken power-law density structure derived from interferometric observations of B335 and the infall model derived from molecular line observations of B335, we find that the opacity ratios are \\frac{\\kappa _{850}}{\\kappa _{2.2}} = (3.21{--}4.80)^{+0.44}_{-0.30} \\times 10^{-4} and \\frac{\\kappa _{450}}{\\kappa _{2.2}} = (12.8{--}24.8)^{+2.4}_{-1.3} \\times 10^{-4}with a submillimeter opacity power-law index of βsmm = (2.18-2.58)+0.30 -0.30. The range of quoted values is determined from the uncertainty in the physical model for B335. For an average 2.2 μm opacity of 3800 ± 700 cm2 g-1, we find a dust opacity at 850 and 450 μm of κ850 = (1.18-1.77)+0.36 -0.24 and κ450 = (4.72-9.13)+1.9 -0.98 cm2 g-1 of dust. These opacities are from (0.65-0.97)κOH5 850 of the widely used theoretical opacities of Ossenkopf and Henning for coagulated ice grains with thin mantles at 850 μm.

  10. Early opacification and subsequent in vivo clearing of a silicone intraocular lens.

    PubMed

    Nikrooyan, Idean; Anderson, Justin E

    2011-09-01

    To report a case of early opacification and spontaneous in vivo clearing of a silicone intraocular lens (IOL). A 79-year-old women underwent uncomplicated cataract extraction and subsequent implantation of a +21.5 D AMO Z9002 (Abbott Medical Optics, Santa Ana, CA) silicone lens. On postoperative day 1, the patient presented with a translucent, milky white appearing, diffuse IOL opacification. On postoperative day 8, the IOL periphery had cleared, but a full thickness haze persisted in the central portion of the optic. By postoperative day 14, the IOL had cleared. To date, the lens has remained clear. One possible mechanism might be exposure to industrial chemicals; however, the manufacturer reports no other similar lens opacities from this manufacturing batch of IOLs. We recommend that surgeons who implant or have implanted an AMO Z9002 silicone IOL and observe similar findings follow the patient closely for resolution of the haze.

  11. Effect of humidity on posterior lens opacification during fluid-air exchange.

    PubMed

    Harlan, J B; Lee, E T; Jensen, P S; de Juan, E

    1999-06-01

    To study the relationship of humidity and the rate of lens opacity formation during fluid-air exchange using an animal model. Vitrectomy and fluid-air exchange was carried out using 16 eyes of 8 pigmented rabbits. One eye of each rabbit was exposed to dry air and the fellow eye received humidified air using an intraocular air humidifier. In each case, the percent humidity of the intraocular air was measured using an in-line hygrometer. Elapsed time from initial air entry to lens feathering was recorded for each eye, with the surgeon-observer unaware of the percent humidity of the air infusion. In each rabbit, use of humidified air resulted in a delay in lens feathering (P<.02), with an overall increase in time to feathering of 80% for humidified air vs room air. Use of a humidifier during fluid-air exchange prolongs intraoperative lens clarity in the rabbit model, suggesting that humidified air should prolong lens clarity during phakic fluid-air exchange in patients. Use of humidified air during vitrectomy and fluid-air exchange may retard the intraoperative loss of lens clarity, promoting better visualization of the posterior segment and enhancing surgical performance.

  12. Relativistic opacities for astrophysical applications

    DOE PAGES

    Fontes, Christopher John; Fryer, Christopher Lee; Hungerford, Aimee L.; ...

    2015-06-29

    Here, we report on the use of the Los Alamos suite of relativistic atomic physics codes to generate radiative opacities for the modeling of astrophysically relevant plasmas under local thermodynamic equilibrium (LTE) conditions. The atomic structure calculations are carried out in fine-structure detail, including full configuration interaction. Three example applications are considered: iron opacities at conditions relevant to the base of the solar convection zone, nickel opacities for the modeling of stellar envelopes, and samarium opacities for the modeling of light curves produced by neutron star mergers. In the first two examples, comparisons are made between opacities that are generatedmore » with the fully and semi-relativistic capabilities in the Los Alamos suite of codes. As expected for these highly charged, iron-peak ions, the two methods produce reasonably similar results, providing confidence that the numerical methods have been correctly implemented. However, discrepancies greater than 10% are observed for nickel and investigated in detail. In the final application, the relativistic capability is used in a preliminary investigation of the complicated absorption spectrum associated with cold lanthanide elements.« less

  13. Chlorogenic acid attenuates hydrogen peroxide-induced oxidative stress in lens epithelial cells

    PubMed Central

    Song, Jike; Guo, Dadong; Bi, Hongsheng

    2018-01-01

    Oxidative stress has an important role in the degradation, oxidation, cross-linking and aggregation of lens proteins, and can trigger lens epithelial cell apoptosis. To investigate the protective effect of chlorogenic acid (CGA) against hydrogen peroxide (H2O2)-induced oxidative stress, human lens epithelial cells (hLECs) were exposed to various concentrations of H2O2 in the presence and absence of CGA. Using MTT assay, reverse transcription-quantitative polymerase chain reaction (RT-qPCR) and ELISA techniques, cell viability, and protein/mRNA levels of BCL2 apoptosis regulator (Bcl-2) and BCL2 associated X apoptosis regulator (Bax) were investigated. Additionally, the levels of intracellular reactive oxygen species (ROS) and apoptosis within cells were measured using flow cytometry to determine the protective effect of CGA on H2O2-induced oxidative stress. Furthermore, the protective effect of CGA on H2O2-induced apoptosis was also examined using rabbit lenses ex vivo. The results indicated that CGA reduced H2O2-induced cytotoxicity in a dose-dependent manner. Flow cytometry analysis demonstrated that simultaneous exposure of hLECs to H2O2 and CGA significantly decreased apoptosis and the levels of ROS. RT-qPCR analysis revealed a decrease in Bcl-2 and an increase in Bax in hLECs following exposure to H2O2 for 24 h, regardless of CGA presence. Furthermore, ELISA results indicate that CGA increased Bcl-2 expression and decreased Bax expression following treatment with H2O2 for 24 h and the Bax/Bcl-2 ratio was significantly decreased by CGA treatment. Lens organ culture experiments indicated a dose-dependent decrease in H2O2-induced lens opacity following CGA treatment. These results suggest that CGA suppresses hLECs apoptosis and prevents lens opacity induced by H2O2 via Bax/Bcl-2 signaling pathway. CGA may provide effective defenses against oxidative stress and, thus, haσ potential as treatment for a variety of diseases in clinical practice. PMID:29207051

  14. Peripheral Defocus of the Monkey Crystalline Lens With Accommodation in a Lens Stretcher

    PubMed Central

    Maceo Heilman, Bianca; Manns, Fabrice; Ruggeri, Marco; Ho, Arthur; Gonzalez, Alex; Rowaan, Cor; Bernal, Andres; Arrieta, Esdras; Parel, Jean-Marie

    2018-01-01

    Purpose To characterize the peripheral defocus of the monkey crystalline lens and its changes with accommodation. Methods Experiments were performed on 15 lenses from 11 cynomolgus monkey eyes (age: 3.8–12.4 years, postmortem time: 33.5 ± 15.3 hours). The tissue was mounted in a motorized lens stretcher to allow for measurements of the lens in the accommodated (unstretched) and unaccommodated (stretched) states. A custom-built combined laser ray tracing and optical coherence tomography system was used to measure the paraxial on-axis and off-axis lens power for delivery angles ranging from −20° to +20° (in air). For each delivery angle, peripheral defocus was quantified as the difference between paraxial off-axis and on-axis power. The peripheral defocus of the lens was compared in the unstretched and stretched states. Results On average, the paraxial on-axis lens power was 52.0 ± 3.4 D in the unstretched state and 32.5 ± 5.1 D in the stretched state. In both states, the lens power increased with increasing delivery angle. From 0° to +20°, the relative peripheral lens power increased by 10.7 ± 1.4 D in the unstretched state and 7.5 ± 1.6 D in the stretched state. The change in field curvature with accommodation was statistically significant (P < 0.001), indicating that the unstretched (accommodated) lens has greater curvature or relative peripheral power. Conclusions The cynomolgus monkey lens has significant accommodation-dependent curvature of field, which suggests that the lens asserts a significant contribution to the peripheral optical performance of the eye that also varies with the state of accommodation.

  15. Relative sensitivity of clinical tests to hydrophilic lens-induced corneal thickness changes.

    PubMed

    Elliott, D B; Fonn, D; Flanagan, J; Doughty, M

    1993-12-01

    The relative sensitivity of the van den Berg Straylightmeter, slitlamp biomicroscopy, a modified optical pachometer, Bailey-Lovie logMAR visual acuity (VA), and two glare tests (The Brightness Acuity Tester used with 10% contrast VA and Pelli-Robson contrast sensitivity) to hydrophilic contact lens-induced edema was assessed in 19 subjects (mean age 25.9 +/- 4.5 years). After baseline assessments, subjects wore thick hydrogel lenses on one eye which was patched tightly for 3 h. Assessments were repeated at frequent intervals after lens removal to assess recovery. None of the pachometer measurements returned to baseline within the 2-h monitoring period, although the majority were within 2% of baseline corneal thickness. The average time for the Straylightmeter scores to recover to baseline values after the lens removal was 90 min, which was similar to the time when visible edema at the slitlamp disappeared. The average time for return to baseline of logMAR VA and the two glare tests was consistently two to three times shorter than the time for the Straylightmeter score. The Straylightmeter therefore provided assessments of corneal edema similar to slitlamp examination and was more sensitive than VA or glare testing.

  16. First contact diagnosis and management of contact lens-related complications.

    PubMed

    Fagan, Xavier J; Jhanji, Vishal; Constantinou, Marios; Amirul Islam, F M; Taylor, Hugh R; Vajpayee, Rasik B

    2012-08-01

    To describe the spectrum of contact lens-related problems in cases presenting to a tertiary referral eye hospital. A retrospective case record analysis of 111 eyes of 97 consecutive patients was undertaken over a period of five months at the Royal Victorian Eye and Ear Hospital, Melbourne, Australia. Contact lens-related complications (CLRC) were classified into microbial keratitis, sterile corneal infiltrates, corneal epitheliopathy and contact lens-related red eye (CLARE). Main parameters examined were nature of the first contact, clinical diagnosis, and management pattern. Forty-two percent of the initial presentations were to health care practitioners (HCPs) other than ophthalmologists. Mean duration from the onset of symptoms to presentation was 6.3 ± 10.9 days. Forty-nine percent (n = 54) of patients had an associated risk factor, most commonly overnight use of contact lenses (n = 14, 13 %). Most common diagnosis at presentation was corneal epitheliopathy (68 %) followed by sterile infiltrates (10 %), CLARE (8 %) and microbial keratitis (6 %). No significant differences were found in the pattern of treatment modalities administered by ophthalmologists and other HCPs. HCPs other than ophthalmologists are the first contact for contact lens-related problems in a significant proportion of patients. These HCPs manage the majority of CLRC by direct treatment or immediate referral.

  17. [Bioinorganic chemical composition of the lens and methods of its investigation].

    PubMed

    Avetisov, S E; Novikov, I A; Pakhomova, N A; Motalov, V G

    2018-01-01

    Bioinorganic chemical composition of the lens of human and experimental animals (cows, dogs, rats, rabbits) have been analyzed in various studies. In most cases, the studies employed different methods to determine the gross (total) composition of chemical elements and their concentrations in the examined samples. Less frequently, they included an assessment of the distribution of chemical elements in the lens and correlation of their concentration with its morphological changes. Chemical elements from all groups (series) of the periodic classification system were discovered in the lens substance. Despite similar investigation methods, different authors obtained contradicting results on the chemical composition of the lens. This article presents data suggesting possible correlation between inorganic chemical elements in the lens substance with the development and formation of lenticular opacities. All currently employed methods are known to only analyze limited number of select chemical elements in the tissues and do not consider the whole range of elements that can be analyzed with existing technology; furthermore, the majority of studies are conducted on the animal model lens. Therefore, it is feasible to continue the development of the chemical microanalysis method by increasing the sensitivity of Scanning Electron Microscopy with Energy Dispersive Spectroscopy (SEM/EDS) with the purpose of assessing the gross chemical composition and distribution of the elements in the lens substance, as well as revealing possible correlation between element concentration and morphological changes in the lens.

  18. Age-related changes in optical and biometric characteristics of emmetropic eyes.

    PubMed

    Atchison, David A; Markwell, Emma L; Kasthurirangan, Sanjeev; Pope, James M; Smith, George; Swann, Peter G

    2008-04-28

    We measured optical and biometric parameters of emmetropic eyes as a function of age. There were approximately 20 subjects each in age groups 18-29, 30-39, 40-49, 50-59, and 60-69 years with similar male and female numbers. One eye was tested for each subject, having spherical equivalent in the range -0.88 D to +0.75 D and age changes: anterior chamber depth decreased 0.011 mm/year, lens central thickness increased 0.024 mm/year, anterior segment depth increased 0.013 mm/year, eye length increased 0.011 mm/year, anterior lens radius of curvature decreased 0.044 mm/year, and lens equivalent refractive index decreased 0.0003/year. Males had higher anterior corneal radii of curvature (0.16 mm), lower lens equivalent refractive index (0.006), longer vitreous lengths (0.51 mm), and longer axial lengths (0.62 mm) than females. Superficially, the results suggest that eyes get bigger as they age. However, results can be related to refraction patterns in which refraction is stable in 20s to 40s and then moves in the hypermetropic direction. It is likely that several young subjects will become hypermetropic as they age, and it is possible that some of the older subjects were myopic when younger.

  19. Measurement of nurses' attitudes and knowledge regarding acute care older patients: Psychometrics of the OPACS-US combined with the KOP-Q.

    PubMed

    Dikken, Jeroen; Hoogerduijn, Jita G; Lagerwey, Mary D; Shortridge-Baggett, Lillie; Klaassen, Sharon; Schuurmans, Marieke J

    In clinical practice, identifying positive and negative attitudes toward older patients is very important to improve quality of care provided to them. The Older People in Acute Care Survey - United States (OPACS-US) is an instrument measuring hospital nurses attitudes regarding older patients. However, psychometrics have never been assessed. Furthermore, knowledge being related to attitude and behavior should also be measured complementing the OPACS-US. The purpose of this study was to assess structural validity and reliability of the OPACS-US and assess whether the OPACS-US can be complemented with the Knowledge about Older Patients-Quiz (KOP-Q). A multicenter cross sectional design was conducted. Registered nurses (n = 130, mean age 39,9 years; working experience 14,6 years) working in four general hospitals were included in the study. Nurses completed the OPACS-US section A: practice experiences, B: general opinion and the KOP-Q online. Findings demonstrated that the OPACS-US is a valid and reliable survey instrument that measures practice experiences and general opinion. Furthermore, the OPACS-US can be combined with the KOP-Q adding a knowledge construct, and is ready for use within education and/or quality improvement programs in the USA. Copyright © 2017 Elsevier Inc. All rights reserved.

  20. A dimensionless ordered pull-through model of the mammalian lens epithelium evidences scaling across species and explains the age-dependent changes in cell density in the human lens

    PubMed Central

    Wu, Jun Jie; Wu, Weiju; Tholozan, Frederique M.; Saunter, Christopher D.; Girkin, John M.; Quinlan, Roy A.

    2015-01-01

    We present a mathematical (ordered pull-through; OPT) model of the cell-density profile for the mammalian lens epithelium together with new experimental data. The model is based upon dimensionless parameters, an important criterion for inter-species comparisons where lens sizes can vary greatly (e.g. bovine (approx. 18 mm); mouse (approx. 2 mm)) and confirms that mammalian lenses scale with size. The validated model includes two parameters: β/α, which is the ratio of the proliferation rate in the peripheral and in the central region of the lens; and γGZ, a dimensionless pull-through parameter that accounts for the cell transition and exit from the epithelium into the lens body. Best-fit values were determined for mouse, rat, rabbit, bovine and human lens epithelia. The OPT model accounts for the peak in cell density at the periphery of the lens epithelium, a region where cell proliferation is concentrated and reaches a maximum coincident with the germinative zone. The β/α ratio correlates with the measured FGF-2 gradient, a morphogen critical to lens cell survival, proliferation and differentiation. As proliferation declines with age, the OPT model predicted age-dependent changes in cell-density profiles, which we observed in mouse and human lenses. PMID:26236824

  1. [Risk of deterministic effects after exposure to low doses of ionizing radiation: retrospective study among health workers in view of a new publication of International Commission on Radiological Protection].

    PubMed

    Negrone, Mario; Di Lascio, Doriana

    2016-01-01

    The new recommended equivalent (publication n. 118 of International Commission on Radiological Protection) dose limit for occupational exposure of the lens of the eye is based on prevention of radiogenic cataracts, with the underlying assumption of a nominal threshold which has been adjusted from 2,5 Gy to 0.5 Gy for acute or protracted exposure. The study aim was to determine the prevalence of ocular lens opacity among healthcare workers (radiologic technologists, physicians, physician assistants) with respect to occupational exposures to ionizing radiations. Therefore, we conducted another retrospective study to explore the relationship between occupational exposure to radiation and opacity lens increase. Healthcare data (current occupational dosimetry, occupational history) are used to investigate risk of increase of opacity lens of eye. The sample of this study consisted of 148 health-workers (64 M and 84 W) aged from 28 to 66 years coming from different hospitals of the ASL of Potenza (clinic, hospital and institute with scientific feature). On the basis of the evaluation of the dosimetric history of the workers (global and effective dose) we agreed to ascribe the group of exposed subjects in cat A (equivalent dose > 2 mSV) and the group of non exposed subjects in cat B (workers with annual absorbed level of dose near 0 mSv). The analisys was conducted using SPSS 15.0 (Statistical Package for Social Science). A trend of increased ocular lens opacity was found with increasing number for workers in highest category of exposure (cat. A, Yates' chi-squared test = 13,7 p = 0,0002); variable significantly related to opacity lens results job: nurse (Χ(2)Y = 14,3 p = 0,0002) physician (Χ(2)Y = 2.2 p = 0,1360) and radiologic technologists (Χ(2)Y = 0,1 p = 0,6691). In conclusion our provides evidence that exposure to relatively low doses of ionizing radiation may be harmful to the lens of the eye and may increase a long-term risk of cataract formation; similary

  2. Lens lipids.

    PubMed

    Zelenka, P S

    1984-11-01

    Lens cells can synthesize, degrade, and remodel lipids. Endogenous lipid synthesis, in conjunction with uptake of exogenous cholesterol and certain fatty acids, leads to the formation of a plasma membrane that is especially rich in sphingomyelin, cholesterol, and long-chain saturated fatty acids. As a result of this unusual lipid composition, lens membranes have very low fluidity, which is restricted even further by lipid-protein interactions. The composition and metabolism of membrane lipids may affect the formation of various types of cataracts. Diets rich in vegetable oils offer some protection against the formation of osmotic cataracts and the hereditary cataract of the RCS rat, although the mechanism of this effect is not clear. Vitamin E also protects against the formation of several types of cataract in vivo and in vitro, suggesting that lipid peroxidation may play a role in cataractogenesis. Certain drugs which inhibit lipid synthesis or degradation are cataractogenic, and a deficiency in cataractogenic, and a deficiency in phosphatidylserine is associated with a loss of Na+/K+ ATPase activity in several types of cataract. Human senile cataracts show a marked loss of protein-lipid interactions, although the overall lipid composition is normal. This loss of protein-lipid interactions may be related to oxidative damage to membrane-associated proteins. Interestingly, the decrease in the fluidity of lens membranes with age would counteract the formation of aqueous pores in the membrane, which can result from the oxidative cross-linking of membrane-associated proteins. Certain pathways of lipid metabolism seem to have regulatory functions. Among these are phosphatidylinositol turnover, phosphatidylethanolamine methylation, and arachidonic acid metabolism. All of these pathways function in the lens. Phosphatidylinositol turnover is correlated with the rate of lens epithelial cell division, while phosphatidylethanolamine methylation seems to be related to the

  3. Quantitative proteomics analysis by iTRAQ in human nuclear cataracts of different ages and normal lens nuclei.

    PubMed

    Zhou, Hai Yan; Yan, Hong; Wang, Li Li; Yan, Wei Jia; Shui, Ying Bo; Beebe, David C

    2015-08-01

    The goal of this study was to quantitatively identify the differentially expressed proteins in nuclear cataracts of different ages and normal lens nuclei in humans. Forty-eight human lens nucleus samples with hardness grades III, IV were obtained during cataract surgery by extracapsular cataract extraction. Seven normal transparent human lens nuclei were obtained from fresh normal cadaver eyes during corneal transplantation surgery. Lens nuclei were divided into seven groups according to age and optic axis: Group A (average age 80.8 ± 1.2 years), Group B (average age 57.0 ± 4.0 years), Group C average age 80.3 ± 4.5 years), Group D (average age 56.9 ± 4.2 years), Group E (average age 78.1 ± 2.5 years), Group F (average age 57.6 ± 3.3 years) and Group G (seven normal transparent human lenses from normal cadaver eyes, average age 34.7 ± 4.2 years). Water-soluble, water-insoluble, and water-insoluble-urea-soluble protein fractions were extracted from samples. The three-part protein fractions from the individual lenses were combined to form the total proteins of each sample. The proteomic profiles of each group were further analyzed using 8-plex iTRAQ labeling combined with 2D-LC-MS/MS. The data were analyzed with the ProteinPilot software for peptide matching, protein identification, and quantification. Differentially expressed proteins were validated by Western blotting. We employed biological and technical replicates and selected the intersection of the two results, which included 80 proteins. Nine proteins were differentially expressed among the 80 proteins identified using proteomic techniques. In age-related nuclear cataracts (ARNC), the expression levels of fatty acid-binding protein and pterin-4-alpha-carbinolamine dehydratase were upregulated, whereas the levels of alpha-crystallin B chain (CRYAB), GSH synthetase, phakinin, gamma-crystallin C, phosphoglycerate kinase 1, betaine-homocysteine S-methyltransferase 1 (BHMT1), and spectrin beta chain were

  4. Deep neural network convolution (NNC) for three-class classification of diffuse lung disease opacities in high-resolution CT (HRCT): consolidation, ground-glass opacity (GGO), and normal opacity

    NASA Astrophysics Data System (ADS)

    Hashimoto, Noriaki; Suzuki, Kenji; Liu, Junchi; Hirano, Yasushi; MacMahon, Heber; Kido, Shoji

    2018-02-01

    Consolidation and ground-glass opacity (GGO) are two major types of opacities associated with diffuse lung diseases. Accurate detection and classification of such opacities are crucially important in the diagnosis of lung diseases, but the process is subjective, and suffers from interobserver variability. Our study purpose was to develop a deep neural network convolution (NNC) system for distinguishing among consolidation, GGO, and normal lung tissue in high-resolution CT (HRCT). We developed ensemble of two deep NNC models, each of which was composed of neural network regression (NNR) with an input layer, a convolution layer, a fully-connected hidden layer, and a fully-connected output layer followed by a thresholding layer. The output layer of each NNC provided a map for the likelihood of being each corresponding lung opacity of interest. The two NNC models in the ensemble were connected in a class-selection layer. We trained our NNC ensemble with pairs of input 2D axial slices and "teaching" probability maps for the corresponding lung opacity, which were obtained by combining three radiologists' annotations. We randomly selected 10 and 40 slices from HRCT scans of 172 patients for each class as a training and test set, respectively. Our NNC ensemble achieved an area under the receiver-operating-characteristic (ROC) curve (AUC) of 0.981 and 0.958 in distinction of consolidation and GGO, respectively, from normal opacity, yielding a classification accuracy of 93.3% among 3 classes. Thus, our deep-NNC-based system for classifying diffuse lung diseases achieved high accuracies for classification of consolidation, GGO, and normal opacity.

  5. Comparison of contact lens and intraocular lens correction of monocular aphakia during infancy: a randomized clinical trial of HOTV optotype acuity at age 4.5 years and clinical findings at age 5 years.

    PubMed

    Lambert, Scott R; Lynn, Michael J; Hartmann, E Eugenie; DuBois, Lindreth; Drews-Botsch, Carolyn; Freedman, Sharon F; Plager, David A; Buckley, Edward G; Wilson, M Edward

    2014-06-01

    The efficacy and safety of primary intraocular lens (IOL) implantation during early infancy is unknown. To compare the visual outcomes of patients optically corrected with contact lenses vs IOLs following unilateral cataract surgery during early infancy. The Infant Aphakia Treatment Study is a randomized clinical trial with 5 years of follow-up that involved 114 infants with unilateral congenital cataracts at 12 sites. A traveling examiner assessed visual acuity at age 4.5 years. Cataract surgery with or without primary IOL implantation. Contact lenses were used to correct aphakia in patients who did not receive IOLs. Treatment was determined through random assignment. HOTV optotype visual acuity at 4.5 years of age. The median logMAR visual acuity was not significantly different between the treated eyes in the 2 treatment groups (both, 0.90 [20/159]; P = .54). About 50% of treated eyes in both groups had visual acuity less than or equal to 20/200. Significantly more patients in the IOL group had at least 1 adverse event after cataract surgery (contact lens, 56%; IOL, 81%; P = .02). The most common adverse events in the IOL group were lens reproliferation into the visual axis, pupillary membranes, and corectopia. Glaucoma/glaucoma suspect occurred in 35% of treated eyes in the contact lens group vs 28% of eyes in the IOL group (P = .55). Since the initial cataract surgery, significantly more patients in the IOL group have had at least 1 additional intraocular surgery (contact lens, 21%; IOL, 72%; P < .001). There was no significant difference between the median visual acuity of operated eyes in children who underwent primary IOL implantation and those left aphakic. However, there were significantly more adverse events and additional intraoperative procedures in the IOL group. When operating on an infant younger than 7 months of age with a unilateral cataract, we recommend leaving the eye aphakic and focusing the eye with a contact lens. Primary IOL

  6. TU-E-201-02: Eye Lens Dosimetry From CT Perfusion Studies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhang, D.

    Madan M. Rehani, Massachusetts General Hospital and Harvard Medical School, Boston Methods for Eye Lens Dosimetry and Studies On Lens Opacities with Interventionalists Radiation induced cataract is a major threat among staff working in interventional suites. Nearly 16 million interventional procedures are performed annually in USA. Recent studies by the principal investigator’s group, primarily among interventional cardiologists, on behalf of the International Atomic Energy Agency, show posterior subcapsular (PSC) changes in the eye lens in 38–53% of main operators and 21–45% of support staff. These changes have potential to lead to cataract in future years, as per information from A-Bombmore » survivors. The International Commission on Radiological Protection has reduced dose limit for staff by a factor of 7.5 (from 150 mSv/y to 20 mSv/y). With increasing emphasis on radiation induced cataracts and reduction in threshold dose for eye lens, there is a need to implement strategies for estimating eye lens dose. Unfortunately eye lens dosimetry is at infancy when it comes to routine application. Various approaches are being tried namely direct measurement using active or passive dosimeters kept close to eyes, retrospective estimations and lastly correlating patient dose in interventional procedures with staff eye dose. The talk will review all approaches available and ongoing active research in this area, as well as data from surveys done in Europe on status of eye dose monitoring in interventional radiology and nuclear medicine. The talk will provide update on how good is Hp(10) against Hp(3), estimations from CTDI values, Monte Carlo based simulations and current status of eye lens dosimetry in USA and Europe. The cataract risk among patients is in CT examinations of the head. Since radiation induced cataract predominantly occurs in posterior sub-capsular (PSC) region and is thus distinguishable from age or drug related cataracts and is also preventable

  7. TU-E-201-00: Eye Lens Dosimetry for Patients and Staff

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    Madan M. Rehani, Massachusetts General Hospital and Harvard Medical School, Boston Methods for Eye Lens Dosimetry and Studies On Lens Opacities with Interventionalists Radiation induced cataract is a major threat among staff working in interventional suites. Nearly 16 million interventional procedures are performed annually in USA. Recent studies by the principal investigator’s group, primarily among interventional cardiologists, on behalf of the International Atomic Energy Agency, show posterior subcapsular (PSC) changes in the eye lens in 38–53% of main operators and 21–45% of support staff. These changes have potential to lead to cataract in future years, as per information from A-Bombmore » survivors. The International Commission on Radiological Protection has reduced dose limit for staff by a factor of 7.5 (from 150 mSv/y to 20 mSv/y). With increasing emphasis on radiation induced cataracts and reduction in threshold dose for eye lens, there is a need to implement strategies for estimating eye lens dose. Unfortunately eye lens dosimetry is at infancy when it comes to routine application. Various approaches are being tried namely direct measurement using active or passive dosimeters kept close to eyes, retrospective estimations and lastly correlating patient dose in interventional procedures with staff eye dose. The talk will review all approaches available and ongoing active research in this area, as well as data from surveys done in Europe on status of eye dose monitoring in interventional radiology and nuclear medicine. The talk will provide update on how good is Hp(10) against Hp(3), estimations from CTDI values, Monte Carlo based simulations and current status of eye lens dosimetry in USA and Europe. The cataract risk among patients is in CT examinations of the head. Since radiation induced cataract predominantly occurs in posterior sub-capsular (PSC) region and is thus distinguishable from age or drug related cataracts and is also preventable

  8. A Comparative Study of Major OPACs in Selected Academic Libraries for Developing Countries: User Study and Subjective User Evaluation.

    ERIC Educational Resources Information Center

    Park, Iljong

    1997-01-01

    A study of five Texas academic libraries provided information on OPAC use by Korean college students to assist system managers select OPACs. The study determined that academic level and age influence preference for the type of OPAC system, that more specific search instructions are needed, and that system menus were the most commonly used source…

  9. The concentration of light in the human lens.

    PubMed Central

    Merriam, J C

    1996-01-01

    PURPOSE: This thesis explores the idea that light energy, especially ultraviolet light, contributes to the unequal distribution of cataract around the world and to the development of cortical opacities. METHODS: In the first section, the thesis reviews historical concepts of the function of the lens and the nature of cataract, epidemiologic data on the global distribution of cataract, and clinical observations of the predominant location of cortical opacification. Second, computer ray tracings and geometric optics demonstrate the passage of light of varying angle of incidence within the lens. Third, two models of the human eye are used to study the refraction of light by the cornea and lens and illustrate the concentration of energy at the equatorial plane of the lens. RESULTS: Cataract prevalence increases with proximity to the earth's equator, and cortical cataract is most common in the inferior and inferonasal lens. Theoretical studies and the eye models both demonstrate that the concentration of light within the lens increases with angle of incidence, and the eye models suggest that the inferior and inferonasal lens receives significantly more energy than other sections of the lens. CONCLUSION: The prevalence of cataract and exposure to ultraviolet energy both increase with decreasing latitude. The most common location of cortical cataract in the inferonasal lens is consistent with the greater dose of light energy received by this portion of the lens. These studies suggest that the global distribution of cataract and the development of cortical cataract are at least in part dependent on the dose of ultraviolet light received by the lens. Images FIGURE 1 FIGURE 2 FIGURE 27 FIGURE 28 FIGURE 29 FIGURE 31 FIGURE 32 FIGURE 33 FIGURE 34 FIGURE 36 FIGURE 37 FIGURE 38 FIGURE 50 FIGURE 51 FIGURE 52 FIGURE 53 FIGURE 54 FIGURE 56 FIGURE 60 FIGURE 61 FIGURE 63 FIGURE 64 FIGURE 65 FIGURE 68 FIGURE 69 FIGURE 70 FIGURE 71 PMID:8981716

  10. The relationship between elastomer opacity, colorimeter beam size, and measured colorimetric response.

    PubMed

    Rugh, E H; Johnston, W M; Hesse, N S

    1991-01-01

    The effect of opacity on the colorimetric responses of large-area and small-area colorimeters was determined using an elastomer intended for maxillofacial prosthetics use and containing various pigments at different concentrations. Opacity was determined by calculating the contrast ratio of 2-mm-thick specimens against black and white backings, using Kubelka-Munk analyses to correct for thickness and backing color variations. The measure of comparison of the two colorimeters was the relative difference in tristimulus reflectance, with the tristimulus reflectance of the large-area colorimeter as the basis of the relative difference. A significant quadratic relationship was found between contrast ratio and the relative difference in tristimulus reflectance. This relationship may be used to describe opacity without the need to make optical observations or measurements of a thin layer of material on contrasting backings. The small-area colorimeter produced color parameters that are a measure of the combined effects of both color and opacity. The importance of beam size considerations of optical measuring devices for translucent natural and prosthetic materials was emphasized.

  11. Life cycle cost evaluation of the digital opacity compliance system.

    PubMed

    McFarland, Michael J; Palmer, Glenn R; Olivas, Arthur C

    2010-01-01

    The US Environmental Protection Agency (EPA) has established EPA Reference Method 9 (Method 9) as the preferred enforcement approach for verifying compliance with federal visible opacity standards. While Method 9 has an extensive history of successful employment, reliance on human observers to quantify visible emissions is inherently subjective, a characteristic that exposes Method 9 results to claims of inaccuracy, bias and, in some cases, outright fraud. The Digital Opacity Compliance System (DOCS), which employs commercial-off-the-shelf digital photography coupled with simple computer processing, is a new approach for quantifying visible opacity. The DOCS technology has been previously demonstrated to meet and, in many cases, surpass the Method 9 accuracy and reliability standards (McFarland et al., 2006). Beyond its performance relative to Method 9, DOCS provides a permanent visual record of opacity, a vital feature in legal compliance challenges. In recent DOCS field testing, the opacity analysis of two hundred and forty one (241) regulated air emissions from the following industrial processes: 1) industrial scrubbers, 2) emergency generators, 3) asphalt paving, 4) steel production and 5) incineration indicated that Method 9 and DOCS were statistically equivalent at the 99% confidence level. However, a life cycle cost analysis demonstrated that implementation of DOCS could potentially save a facility $15,732 per trained opacity observer compared to utilization of Method 9. Copyright 2009 Elsevier Ltd. All rights reserved.

  12. Spectrally resolved opacities and Rosseland and Planck mean opacities of lowly ionized gold plasmas: a detailed level-accounting investigation.

    PubMed

    Zeng, Jiaolong; Yuan, Jianmin

    2007-08-01

    Calculation details of radiative opacity for lowly ionized gold plasmas by using our developed fully relativistic detailed level-accounting approach are presented to show the importance of accurate atomic data for a quantitative reproduction of the experimental observations. Even though a huge number of transition lines are involved in the radiative absorption of high- Z plasmas so that one believes that statistical models can often give a reasonable description of their opacities, we first show in detail that an adequate treatment of physical effects, in particular the configuration interaction (including the core-valence electron correlation), is essential to produce atomic data of bound-bound and bound-free processes for gold plasmas, which are accurate enough to correctly explain the relative intensity of two strong absorption peaks experimentally observed located near photon energy of 70 and 80 eV. A detailed study is also carried out for gold plasmas of an average ionization degree sequence of 10, for both spectrally resolved opacities and Rosseland and Planck means. For comparison, results obtained by using an average atom model are also given to show that even for a relatively higher density of matter, correlation effects are also important to predict the correct positions of absorption peaks of transition arrays.

  13. Web OPAC Interfaces: An Overview.

    ERIC Educational Resources Information Center

    Babu, B. Ramesh; O'Brien, Ann

    2000-01-01

    Discussion of Web-based online public access catalogs (OPACs) focuses on a review of six Web OPAC interfaces in use in academic libraries in the United Kingdom. Presents a checklist and guidelines of important features and functions that are currently available, including search strategies, access points, display, links, and layout. (Author/LRW)

  14. Redesigning the OPAC: Moving outside the ILMS

    ERIC Educational Resources Information Center

    Sokvitne, Lloyd O.

    2006-01-01

    The need to develop new OPACs that meet the needs of users better is becoming well acknowledged. How libraries can transform their OPACs to modern web friendly formats is not yet clear. This paper describes the State Library of Tasmania's experience in developing a new OPAC by exporting bibliographic data to a software package outside the ILMS.…

  15. The effect of lens aging and cataract surgery on circadian rhythm.

    PubMed

    Yan, Shen-Shen; Wang, Wei

    2016-01-01

    Many organisms have evolved an approximately 24-hour circadian rhythm that allows them to achieve internal physiological homeostasis with external environment. Suprachiasmatic nucleus (SCN) is the central pacemaker of circadian rhythm, and its activity is entrained to the external light-dark cycle. The SCN controls circadian rhythm through regulating the synthesis of melatonin by pineal gland via a multisynaptic pathway. Light, especially short-wavelength blue light, is the most potent environmental time cue in circadian photoentrainment. Recently, the discovery of a novel type of retinal photoreceptors, intrinsically photosensitive retinal ganglion cells, sheds light on the mechanism of circadian photoentrainment and raises concerns about the effect of ocular diseases on circadian system. With age, light transmittance is significantly decreased due to the aging of crystalline lens, thus possibly resulting in progressive loss of circadian photoreception. In the current review, we summarize the circadian physiology, highlight the important role of light in circadian rhythm regulation, discuss about the correlation between age-related cataract and sleep disorders, and compare the effect of blue light- filtering intraocular lenses (IOLs) and ultraviolet only filtering IOLs on circadian rhythm.

  16. Guidance on radiation dose limits for the lens of the eye: overview of the recommendations in NCRP Commentary No. 26.

    PubMed

    Dauer, Lawrence T; Ainsbury, Elizabeth A; Dynlacht, Joseph; Hoel, David; Klein, Barbara E K; Mayer, Donald; Prescott, Christina R; Thornton, Raymond H; Vano, Eliseo; Woloschak, Gayle E; Flannery, Cynthia M; Goldstein, Lee E; Hamada, Nobuyuki; Tran, Phung K; Grissom, Michael P; Blakely, Eleanor A

    2017-10-01

    This review summarizes the conclusions and recommendations of the new National Council on Radiation Protection and Measurements (NCRP) Commentary No. 26 guidance on radiation dose limits for the lens of the eye. The NCRP addressed radiation protection principles in respect to the lens of the eye, discussed the current understanding of eye biology and lens effects, reviewed and evaluated epidemiology, and assessed exposed populations with the potential for significant radiation exposures to the lens while suggesting monitoring and protection practices. Radiation-induced damage to the lens of the eye can include the loss of clarity resulting in opacification or clouding several years after exposure. The impact is highly dependent on the type of radiation, how the exposure of the lens was delivered, the genetic susceptibilities of the individual exposed, and the location of the opacity relative to the visual axis of the individual. The preponderance of epidemiological evidence suggests that lens damage could occur at lower doses than previously considered and the NCRP has determined that it is prudent to reduce the recommended annual lens of the eye occupational dose limit from an equivalent dose of 150 mSv to an absorbed dose of 50 mGy. Significant additional research is still needed in the following areas: comprehensive evaluation of the overall effects of ionizing radiation on the eye, dosimetry methodology and dose-sparing optimization techniques, additional high quality epidemiology studies, and a basic understanding of the mechanisms of cataract development.

  17. Talking Relative Age Effects: A Fictional Analysis Based on Scientific Evidence

    ERIC Educational Resources Information Center

    Roberts, Simon J.

    2014-01-01

    During the past 30 years, there has been a considerable amount of scientific attention dedicated to the reported age discrimination which occurs in youth and elite sport. The purpose of this paper is to examine the notion of relative age effects (RAEs) through a slightly different lens. This paper therefore presents a fictional conversation…

  18. Age-dependence of the optomechanical responses of ex vivo human lenses from India and the USA, and the force required to produce these in a lens stretcher: the similarity to in vivo disaccommodation

    PubMed Central

    Augusteyn, Robert C; Mohamed, Ashik; Nankivil, Derek; Veerendranath, Pesala; Arrieta, Esdras; Taneja, Mukesh; Manns, Fabrice; Ho, Arthur; Parel, Jean-Marie

    2011-01-01

    The purpose of this study was to study the age-dependence of the optomechanical properties of human lenses during simulated disaccommodation in a mechanical lens stretcher, designed to determine accommodative forces as a function of stretch distance, to compare the results with in vivo disaccommodation and to examine whether differences exist between eyes harvested in the USA and India. Post-mortem human eyes obtained in the USA (n=46, age = 6 to 83 years) and India (n=91, age = 1 day to 85 years) were mounted in an optomechanical lens stretching system and dissected to expose the lens complete with its accommodating framework, including zonules, ciliary body, anterior vitreous and a segmented rim of sclera. Disaccommodation was simulated through radial stretching of the sectioned globe by 2 mm in increments of 0.25 mm. The load, inner ciliary ring diameter, lens equatorial diameter, central thickness and power were measured at each step. Changes in these parameters were examined as a function of age, as were the dimension/load and power/load responses. Unstretched lens diameter and thickness increased over the whole age range examined and were indistinguishable from those of in vivo lenses as well as those of in vitro lenses freed from zonular attachments. Stretching increased the diameter and decreased the thickness in all lenses examined but the amount of change decreased with age. Unstretched lens power decreased with age and the accommodative amplitude decreased to zero by age 45-50. The load required to produce maximum stretch was independent of age (median 80 mN) whereas the change in lens diameter and power per unit load decreased significantly with age. The age related changes in the properties of human lenses, as observed in the lens stretching device, are similar to those observed in vivo and are consistent with the classical Helmholtz theory of accommodation. The response of lens diameter and power to disaccommodative (stretching) forces decreases with

  19. Racemized and Isomerized Proteins in Aging Rat Teeth and Eye Lens

    PubMed Central

    Warmack, Rebeccah A.; Mansilla, Eduardo; Goya, Rodolfo G.

    2016-01-01

    Abstract The quantification of aspartic acid racemization in the proteins of nonmetabolically active tissues can be used as a measure of chronological aging in humans and other long-lived organisms. However, very few studies have been conducted in shorter-lived animals such as rodents, which are increasingly used as genetic and metabolic models of aging. An initial study had reported significant changes in the ratio of d- to l-aspartate in rat molars with age. Using a sensitive HPLC method for the determination of d- and l-aspartate from protein hydrolysates, we found no accumulation of d-aspartate in the molars of 17 rats that ranged in age from 2 to 44 months, and the amount of d-aspartate per molar did not correspond with molar eruption date as had been previously reported. However, developing an alternate approach, we found significant accumulation of isomerized aspartyl residues in eye lens proteins that are also formed by spontaneous degradation processes. In this study, we used the human protein l-isoaspartate/d-aspartate O-methyltransferase (PCMT1) as an analytical reagent in a sensitive and convenient procedure that could be used to rapidly examine multiple samples simultaneously. We found levels of isomerized aspartyl residues to be about 35 times higher in the lens extracts of 18-month-old rats versus 2-month-old rats, suggesting that isomerization may be an effective marker for biological aging in this range of ages. Importantly, we found that the accumulation appeared to plateau in rats of 18 months and older, indicating that potentially novel mechanisms for removing altered proteins may develop with age. PMID:26650547

  20. Contact Lens Solutions and Contact Lens Discomfort: Examining the Correlations Between Solution Components, Keratitis, and Contact Lens Discomfort.

    PubMed

    Kuc, Christopher J; Lebow, Kenneth A

    2018-06-13

    This article will examine the current literature, as it relates to contact lens discomfort (CLD) secondary to contact lens solutions. The reader will better understand the characteristics of contact lenses, as they uniquely interact with each type of contact lens solution and also gain a better comprehension of the components of contact lens solution such as preservatives, surfactants, and chelating agents, which may contribute to discomfort. By investigating corneal staining theory and the mechanisms that contribute to its presence, the reader will gain insight into this clinical finding, which relates to selection of contact lens solutions. The FDA standards for testing solutions and how this relates to contact lens keratitis will also be appraised in regards to current ISO recommendations. Finally, better selection of multipurpose contact lens solution (MPS) and hydrogen peroxide-based solutions for patients should be accessible to the clinician based on this review and preexisting clinical findings or diagnoses. A review of current published literature from peer reviewed journals and online journals was conducted to gain an understanding of contact lens solution's impact on contact lens discomfort. Many studies have been conducted comparing comfort between various types of contact lens solutions. It is challenging to decipher this information and apply it clinically when selecting solutions for patients. By comparing solution components, how contact lens solutions interact with different types of lenses, keratitis related to contact lenses, and preexisting ocular conditions, this review will improve a clinician's ability to eliminate CLD.

  1. Method for quantifying optical properties of the human lens

    DOEpatents

    Loree, deceased, Thomas R.; Bigio, Irving J.; Zuclich, Joseph A.; Shimada, Tsutomu; Strobl, Karlheinz

    1999-01-01

    Method for quantifying optical properties of the human lens. The present invention includes the application of fiberoptic, OMA-based instrumentation as an in vivo diagnostic tool for the human ocular lens. Rapid, noninvasive and comprehensive assessment of the optical characteristics of a lens using very modest levels of exciting light are described. Typically, the backscatter and fluorescence spectra (from about 300- to 900-nm) elicited by each of several exciting wavelengths (from about 300- to 600-nm) are collected within a few seconds. The resulting optical signature of individual lenses is then used to assess the overall optical quality of the lens by comparing the results with a database of similar measurements obtained from a reference set of normal human lenses having various ages. Several metrics have been identified which gauge the optical quality of a given lens relative to the norm for the subject's chronological age. These metrics may also serve to document accelerated optical aging and/or as early indicators of cataract or other disease processes.

  2. Method for quantifying optical properties of the human lens

    DOEpatents

    Loree, T.R.; Bigio, I.J.; Zuclich, J.A.; Shimada, Tsutomu; Strobl, K.

    1999-04-13

    A method is disclosed for quantifying optical properties of the human lens. The present invention includes the application of fiberoptic, OMA-based instrumentation as an in vivo diagnostic tool for the human ocular lens. Rapid, noninvasive and comprehensive assessment of the optical characteristics of a lens using very modest levels of exciting light are described. Typically, the backscatter and fluorescence spectra (from about 300- to 900-nm) elicited by each of several exciting wavelengths (from about 300- to 600-nm) are collected within a few seconds. The resulting optical signature of individual lenses is then used to assess the overall optical quality of the lens by comparing the results with a database of similar measurements obtained from a reference set of normal human lenses having various ages. Several metrics have been identified which gauge the optical quality of a given lens relative to the norm for the subject`s chronological age. These metrics may also serve to document accelerated optical aging and/or as early indicators of cataract or other disease processes. 8 figs.

  3. The structural alteration and aggregation propensity of glycated lens crystallins in the presence of calcium: Importance of lens calcium homeostasis in development of diabetic cataracts

    NASA Astrophysics Data System (ADS)

    ZM, Sara Zafaranchi; Khoshaman, Kazem; Masoudi, Raheleh; Hemmateenejad, Bahram; Yousefi, Reza

    2017-01-01

    The imbalance of the calcium homeostasis in the lenticular tissues of diabetic patients is an important risk factor for development of cataract diseases. In the current study, the impact of elevated levels of calcium ions were investigated on structure and aggregation propensity of glycated lens crystallins using gel electrophoresis and spectroscopic assessments. The glycated proteins indicated significant resistance against calcium-induced structural insults and aggregation. While, glycated crystallins revealed an increased conformational stability; a slight instability was observed for these proteins upon interaction with calcium ions. Also, in the presence of calcium, the proteolytic pattern of native crystallins was altered and that of glycated protein counterparts remained almost unchanged. According to results of this study it is suggested that the structural alteration of lens crystallins upon glycation may significantly reduce their calcium buffering capacity in eye lenses. Therefore, under chronic hyperglycemia accumulation of this cataractogenic metal ion in the lenticular tissues may subsequently culminate in activation of different pathogenic pathways, leading to development of lens opacity and cataract diseases.

  4. The GUI OPAC: Approach with Caution.

    ERIC Educational Resources Information Center

    Hildreth, Charles R.

    1995-01-01

    Discusses the graphical user interface (GUI) online public access catalog (OPAC), a user interface that uses images to represent options. Topics include user interface design for information retrieval; designing effective bibliographic displays, including subject headings; two design principles; and what GUIs can bring to OPACs. (LRW)

  5. The effect of lens aging and cataract surgery on circadian rhythm

    PubMed Central

    Yan, Shen-Shen; Wang, Wei

    2016-01-01

    Many organisms have evolved an approximately 24-hour circadian rhythm that allows them to achieve internal physiological homeostasis with external environment. Suprachiasmatic nucleus (SCN) is the central pacemaker of circadian rhythm, and its activity is entrained to the external light-dark cycle. The SCN controls circadian rhythm through regulating the synthesis of melatonin by pineal gland via a multisynaptic pathway. Light, especially short-wavelength blue light, is the most potent environmental time cue in circadian photoentrainment. Recently, the discovery of a novel type of retinal photoreceptors, intrinsically photosensitive retinal ganglion cells, sheds light on the mechanism of circadian photoentrainment and raises concerns about the effect of ocular diseases on circadian system. With age, light transmittance is significantly decreased due to the aging of crystalline lens, thus possibly resulting in progressive loss of circadian photoreception. In the current review, we summarize the circadian physiology, highlight the important role of light in circadian rhythm regulation, discuss about the correlation between age-related cataract and sleep disorders, and compare the effect of blue light- filtering intraocular lenses (IOLs) and ultraviolet only filtering IOLs on circadian rhythm. PMID:27500118

  6. Intraocular lenses in age-related macular degeneration.

    PubMed

    Grzybowski, Andrzej; Wasinska-Borowiec, Weronika; Alio, Jorge L; Amat-Peral, Pedro; Tabernero, Juan

    2017-09-01

    The aim of this work is to review the lenses, assessing their advantages and disadvantages. We describe a total of seven types of intraocular lenses (IOLs) recommended for age-related macular degeneration (AMD). We used the PubMed web platform to search for implantable devices in various stages of AMD. We searched for both prospective and retrospective studies and also case reports. Clinical results in AMD patients have been described for a total of seven types of IOLs recommended for AMD: an implantable miniature telescope (IMT), IOL-VIP System, Lipshitz macular implant (LMI), sulcus-implanted Lipshitz macular implant, LMI-SI, Fresnel Prism Intraocular Lens, iolAMD and Scharioth Macula Lens. We conclude that to objectively ascertain the effectiveness and safety of these lenses, further independent clinical studies with longer follow-up data are necessary prior to the general use of these optical devices.

  7. Diagnostic performance of qualitative shear-wave elastography according to different color map opacities for breast masses.

    PubMed

    Kim, Hana; Youk, Ji Hyun; Gweon, Hye Mi; Kim, Jeong-Ah; Son, Eun Ju

    2013-08-01

    To compare the diagnostic performance of qualitative shear-wave elastography (SWE) according to three different color map opacities for breast masses 101 patients aged 21-77 years with 113 breast masses underwent B-mode US and SWE under three different color map opacities (50%, 19% and 100%) before biopsy or surgery. Following SWE features were reviewed: visual pattern classification (pattern 1-4), color homogeneity (Ehomo) and six-point color score of maximum elasticity (Ecol). Combined with B-mode US and SWE, the likelihood of malignancy (LOM) was also scored. The area under the curve (AUC) was obtained by ROC curve analysis to assess the diagnostic performance under each color opacity. A visual color pattern, Ehomo, Ecol and LOM scoring were significantly different between benign and malignant lesions under all color opacities (P<0.001). For 50% opacity, AUCs of visual color pattern, Ecol, Ehomo and LOM scoring were 0.902, 0.951, 0.835 and 0.975. But, for each SWE feature, there was no significant difference in the AUC among three different color opacities. For all color opacities, visual color pattern and Ecol showed significantly higher AUC than Ehomo. In addition, a combined set of B-mode US and SWE showed significantly higher AUC than SWE alone for color patterns, Ehomo, but no significant difference was found in Ecol. Qualitative SWE was useful to differentiate benign from malignant breast lesion under all color opacities. The difference in color map opacity did not significantly influence diagnostic performance of SWE. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  8. Changes in Monkey Crystalline Lens Spherical Aberration During Simulated Accommodation in a Lens Stretcher

    PubMed Central

    Maceo Heilman, Bianca; Manns, Fabrice; de Castro, Alberto; Durkee, Heather; Arrieta, Esdras; Marcos, Susana; Parel, Jean-Marie

    2015-01-01

    Purpose. The purpose of this study was to quantify accommodation-induced changes in the spherical aberration of cynomolgus monkey lenses. Methods. Twenty-four lenses from 20 cynomolgus monkeys (Macaca fascicularis; 4.4–16.0 years of age; postmortem time 13.5 ± 13.0 hours) were mounted in a lens stretcher. Lens spherical aberration was measured in the unstretched (accommodated) and stretched (relaxed) states with a laser ray tracing system that delivered 51 equally spaced parallel rays along 1 meridian of the lens over the central 6-mm optical zone. A camera mounted below the lens was used to measure the ray height at multiple positions along the optical axis. For each entrance ray, the change in ray height with axial position was fitted with a third-order polynomial. The effective paraxial focal length and Zernike spherical aberration coefficients corresponding to a 6-mm pupil diameter were extracted from the fitted values. Results. The unstretched lens power decreased with age from 59.3 ± 4.0 diopters (D) for young lenses to 45.7 ± 3.1 D for older lenses. The unstretched lens shifted toward less negative spherical aberration with age, from −6.3 ± 0.7 μm for young lenses to −5.0 ± 0.5 μm for older lenses. The power and spherical aberration of lenses in the stretched state were independent of age, with values of 33.5 ± 3.4 D and −2.6 ± 0.5 μm, respectively. Conclusions. Spherical aberration is negative in cynomolgus monkey lenses and becomes more negative with accommodation. These results are in good agreement with the predicted values using computational ray tracing in a lens model with a reconstructed gradient refractive index. The spherical aberration of the unstretched lens becomes less negative with age. PMID:25670492

  9. Changes in monkey crystalline lens spherical aberration during simulated accommodation in a lens stretcher.

    PubMed

    Maceo Heilman, Bianca; Manns, Fabrice; de Castro, Alberto; Durkee, Heather; Arrieta, Esdras; Marcos, Susana; Parel, Jean-Marie

    2015-02-10

    The purpose of this study was to quantify accommodation-induced changes in the spherical aberration of cynomolgus monkey lenses. Twenty-four lenses from 20 cynomolgus monkeys (Macaca fascicularis; 4.4-16.0 years of age; postmortem time 13.5 ± 13.0 hours) were mounted in a lens stretcher. Lens spherical aberration was measured in the unstretched (accommodated) and stretched (relaxed) states with a laser ray tracing system that delivered 51 equally spaced parallel rays along 1 meridian of the lens over the central 6-mm optical zone. A camera mounted below the lens was used to measure the ray height at multiple positions along the optical axis. For each entrance ray, the change in ray height with axial position was fitted with a third-order polynomial. The effective paraxial focal length and Zernike spherical aberration coefficients corresponding to a 6-mm pupil diameter were extracted from the fitted values. The unstretched lens power decreased with age from 59.3 ± 4.0 diopters (D) for young lenses to 45.7 ± 3.1 D for older lenses. The unstretched lens shifted toward less negative spherical aberration with age, from -6.3 ± 0.7 μm for young lenses to -5.0 ± 0.5 μm for older lenses. The power and spherical aberration of lenses in the stretched state were independent of age, with values of 33.5 ± 3.4 D and -2.6 ± 0.5 μm, respectively. Spherical aberration is negative in cynomolgus monkey lenses and becomes more negative with accommodation. These results are in good agreement with the predicted values using computational ray tracing in a lens model with a reconstructed gradient refractive index. The spherical aberration of the unstretched lens becomes less negative with age. Copyright 2015 The Association for Research in Vision and Ophthalmology, Inc.

  10. Replicating the Z iron opacity experiments on the NIF

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Perry, T. S.; Heeter, R. F.; Opachich, Y. P.

    Here, X-ray opacity is a crucial factor of all radiation-hydrodynamics calculations, yet it is one of the least validated of the material properties in the simulation codes. Recent opacity experiments at the Sandia Z-machine have shown up to factors of two discrepancies between theory and experiment, casting doubt on the validity of the opacity models. Therefore, a new experimental opacity platform is being developed on the National Ignition Facility (NIF) not only to verify the Z-machine experimental results but also to extend the experiments to other temperatures and densities. The first experiments will be directed towards measuring the opacity ofmore » iron at a temperature of ~160 eV and an electron density of ~7 x 10 21 cm -3. Preliminary experiments on NIF have demonstrated the ability to create a sufficiently bright point backlighter using an imploding plastic capsule and also a hohlraum that can heat the opacity sample to the desired conditions. The first of these iron opacity experiments is expected to be performed in 2017.« less

  11. Replicating the Z iron opacity experiments on the NIF

    NASA Astrophysics Data System (ADS)

    Perry, T. S.; Heeter, R. F.; Opachich, Y. P.; Ross, P. W.; Kline, J. L.; Flippo, K. A.; Sherrill, M. E.; Dodd, E. S.; DeVolder, B. G.; Cardenas, T.; Archuleta, T. N.; Craxton, R. S.; Zhang, R.; McKenty, P. W.; Garcia, E. M.; Huffman, E. J.; King, J. A.; Ahmed, M. F.; Emig, J. A.; Ayers, S. L.; Barrios, M. A.; May, M. J.; Schneider, M. B.; Liedahl, D. A.; Wilson, B. G.; Urbatsch, T. J.; Iglesias, C. A.; Bailey, J. E.; Rochau, G. A.

    2017-06-01

    X-ray opacity is a crucial factor of all radiation-hydrodynamics calculations, yet it is one of the least validated of the material properties in the simulation codes. Recent opacity experiments at the Sandia Z-machine have shown up to factors of two discrepancies between theory and experiment, casting doubt on the validity of the opacity models. Therefore, a new experimental opacity platform is being developed on the National Ignition Facility (NIF) not only to verify the Z-machine experimental results but also to extend the experiments to other temperatures and densities. The first experiments will be directed towards measuring the opacity of iron at a temperature of ∼160 eV and an electron density of ∼7 × 1021 cm-3. Preliminary experiments on NIF have demonstrated the ability to create a sufficiently bright point backlighter using an imploding plastic capsule and also a hohlraum that can heat the opacity sample to the desired conditions. The first of these iron opacity experiments is expected to be performed in 2017.

  12. Replicating the Z iron opacity experiments on the NIF

    DOE PAGES

    Perry, T. S.; Heeter, R. F.; Opachich, Y. P.; ...

    2017-05-12

    Here, X-ray opacity is a crucial factor of all radiation-hydrodynamics calculations, yet it is one of the least validated of the material properties in the simulation codes. Recent opacity experiments at the Sandia Z-machine have shown up to factors of two discrepancies between theory and experiment, casting doubt on the validity of the opacity models. Therefore, a new experimental opacity platform is being developed on the National Ignition Facility (NIF) not only to verify the Z-machine experimental results but also to extend the experiments to other temperatures and densities. The first experiments will be directed towards measuring the opacity ofmore » iron at a temperature of ~160 eV and an electron density of ~7 x 10 21 cm -3. Preliminary experiments on NIF have demonstrated the ability to create a sufficiently bright point backlighter using an imploding plastic capsule and also a hohlraum that can heat the opacity sample to the desired conditions. The first of these iron opacity experiments is expected to be performed in 2017.« less

  13. Hydrodynamical instabilities induced by atomic diffusion in F and A stars : Impact on the opacity profile and asteroseimic age determination

    NASA Astrophysics Data System (ADS)

    Deal, M.; Richard, O.; Vauclair, S.

    2017-12-01

    Atomic diffusion, including the effect of radiative accelerations on individual elements, leads to important variations of the chemical composition inside the stars. The accumulation in specific layers of the elements, which are the main contributors of the local opacity, leads to hydrodynamical instabilities that modify the internal stellar structure and surface abundances. The modification of the initial chemical composition has important effects on the internal stellar mixing and leads to different surface and internal abundances of the elements. These processes also modify the age determination by asteroseismology.

  14. Opacity from two-photon processes

    DOE PAGES

    More, Richard M.; Hansen, Stephanie B.; Nagayama, Taisuke

    2017-07-22

    Here, the recent iron opacity measurements performed at Sandia National Laboratory by Bailey and collaborators have raised questions about the completeness of the physical models normally used to understand partially ionized hot dense plasmas. We describe calculations of two-photon absorption, which is a candidate for the observed extra opacity. Our calculations do not yet match the experiments but show that the two-photon absorption process is strong enough to require careful consideration.

  15. Postoperative diffuse opacification of a hydrophilic acrylic intraocular lens: analysis of an explant.

    PubMed

    Cavallini, Gian Maria; Volante, Veronica; Campi, Luca; De Maria, Michele; Fornasari, Elisa; Urso, Giancarlo

    2017-06-14

    We describe the clinicopathological and ultrastructural features of an opaque single-piece hydrophilic acrylic intraocular lens (IOL) explanted from a patient. The main outcome of this report is the documentation of calcium deposits confirmed by surface analysis. The decrease in visual acuity was due to the opacification of the IOL. The opacification involved both the optic plate and the haptics. The analysis at the scansion electron microscope revealed that the opacity was caused by the deposition of calcium and phosphate within the lens optic and haptics. This is the first case about the opacification of an Oculentis L-313. The opacification was characterized by calcium and phosphate deposition probably due to a morphological alteration of the posterior surface of the IOL.

  16. Effect of contact lens use on Computer Vision Syndrome.

    PubMed

    Tauste, Ana; Ronda, Elena; Molina, María-José; Seguí, Mar

    2016-03-01

    To analyse the relationship between Computer Vision Syndrome (CVS) in computer workers and contact lens use, according to lens materials. Cross-sectional study. The study included 426 civil-service office workers, of whom 22% were contact lens wearers. Workers completed the Computer Vision Syndrome Questionnaire (CVS-Q) and provided information on their contact lenses and exposure to video display terminals (VDT) at work. CVS was defined as a CVS-Q score of 6 or more. The covariates were age and sex. Logistic regression was used to calculate the association (crude and adjusted for age and sex) between CVS and individual and work-related factors, and between CVS and contact lens type. Contact lens wearers are more likely to suffer CVS than non-lens wearers, with a prevalence of 65% vs 50%. Workers who wear contact lenses and are exposed to the computer for more than 6 h day(-1) are more likely to suffer CVS than non-lens wearers working at the computer for the same amount of time (aOR = 4.85; 95% CI, 1.25-18.80; p = 0.02). Regular contact lens use increases CVS after 6 h of computer work. © 2016 The Authors Ophthalmic & Physiological Optics © 2016 The College of Optometrists.

  17. Effect of oil on an electrowetting lenticular lens and related optical characteristics.

    PubMed

    Shin, Dooseub; Kim, Junoh; Kim, Cheoljoong; Koo, Gyo Hyun; Sim, Jee Hoon; Lee, Junsik; Won, Yong Hyub

    2017-03-01

    While there are many ways to realize autostereoscopic 2D/3D switchable displays, the electrowetting lenticular lens is superior due to the high optical efficiency and short response time. In this paper, we propose a more stable electrowetting lenticular lens by controlling the quantity of oil. With a large amount of oil, the oil layer was broken and the lenticular lens was damaged at relatively low voltage. Therefore, controlling the amount of oil is crucial to obtain the required dioptric power with stability. We proposed a new structure to evenly adjust the volume of oil and the dioptric power was measured by varying the volume of oil. Furthermore, the optical characteristics were finally analyzed in the electrowetting lenticular lens array with a proper amount of oil.

  18. Folic Acid, Vitamin B6, and Vitamin B12 in Combination and Age-Related Cataract in a Randomized Trial of Women.

    PubMed

    Christen, William G; Glynn, Robert J; Chew, Emily Y; Albert, Christine M; Manson, JoAnn E

    2016-01-01

    To examine the incidence of cataract and cataract extraction in a trial of folic acid and vitamins B6 and B12. In a randomized, double-masked, placebo-controlled trial, 5442 female health professionals aged 40 years or older with preexisting cardiovascular disease (CVD) or three or more CVD risk factors were randomly assigned to receive a combination of folic acid (2.5 mg/day), vitamin B6 (50 mg/day), and vitamin B12 (1 mg/day), or placebo. A total of 3925 of these women did not have a diagnosis of cataract at baseline and were included in this analysis. The primary endpoint was age-related cataract, defined as an incident age-related lens opacity, responsible for a reduction in best-corrected visual acuity to 20/30 or worse, based on self-report confirmed by medical record review. Extraction of incident age-related cataract was a secondary endpoint of the trial. During an average of 7.3 years of treatment and follow-up, 408 cataracts and 275 cataract extractions were documented. There were 215 cataracts in the combination treatment group and 193 in the placebo group (hazard ratio, HR, 1.10, 95% confidence interval, CI, 0.90-1.33; p = 0.36). For the secondary endpoint of cataract extraction, there were 155 in the combination treatment group and 120 in the placebo group (HR 1.28, 95% CI 1.01-1.63; p = 0.04). In this large-scale randomized trial of women at high risk of CVD, daily supplementation with a combination of folic acid, vitamin B6, and vitamin B12 had no significant effect on cataract, but may have increased the risk of cataract extraction.

  19. A New Generation of Los Alamos Opacity Tables

    DOE PAGES

    Colgan, James Patrick; Kilcrease, David Parker; Magee, Jr., Norman H.; ...

    2016-01-26

    We present a new, publicly available, set of Los Alamos OPLIB opacity tables for the elements hydrogen through zinc. Our tables are computed using the Los Alamos ATOMIC opacity and plasma modeling code, and make use of atomic structure calculations that use fine-structure detail for all the elements considered. Our equation-of-state (EOS) model, known as ChemEOS, is based on the minimization of free energy in a chemical picture and appears to be a reasonable and robust approach to determining atomic state populations over a wide range of temperatures and densities. In this paper we discuss in detail the calculations thatmore » we have performed for the 30 elements considered, and present some comparisons of our monochromatic opacities with measurements and other opacity codes. We also use our new opacity tables in solar modeling calculations and compare and contrast such modeling with previous work.« less

  20. Radiation Transport for Explosive Outflows: Opacity Regrouping

    NASA Astrophysics Data System (ADS)

    Wollaeger, Ryan T.; van Rossum, Daniel R.

    2014-10-01

    Implicit Monte Carlo (IMC) and Discrete Diffusion Monte Carlo (DDMC) are methods used to stochastically solve the radiative transport and diffusion equations, respectively. These methods combine into a hybrid transport-diffusion method we refer to as IMC-DDMC. We explore a multigroup IMC-DDMC scheme that in DDMC, combines frequency groups with sufficient optical thickness. We term this procedure "opacity regrouping." Opacity regrouping has previously been applied to IMC-DDMC calculations for problems in which the dependence of the opacity on frequency is monotonic. We generalize opacity regrouping to non-contiguous groups and implement this in SuperNu, a code designed to do radiation transport in high-velocity outflows with non-monotonic opacities. We find that regrouping of non-contiguous opacity groups generally improves the speed of IMC-DDMC radiation transport. We present an asymptotic analysis that informs the nature of the Doppler shift in DDMC groups and summarize the derivation of the Gentile-Fleck factor for modified IMC-DDMC. We test SuperNu using numerical experiments including a quasi-manufactured analytic solution, a simple 10 group problem, and the W7 problem for Type Ia supernovae. We find that opacity regrouping is necessary to make our IMC-DDMC implementation feasible for the W7 problem and possibly Type Ia supernova simulations in general. We compare the bolometric light curves and spectra produced by the SuperNu and PHOENIX radiation transport codes for the W7 problem. The overall shape of the bolometric light curves are in good agreement, as are the spectra and their evolution with time. However, for the numerical specifications we considered, we find that the peak luminosity of the light curve calculated using SuperNu is ~10% less than that calculated using PHOENIX.

  1. New Generation of Los Alamos Opacity Tables

    NASA Astrophysics Data System (ADS)

    Colgan, James; Kilcrease, D. P.; Magee, N. H.; Sherrill, M. E.; Abdallah, J.; Hakel, P.; Fontes, C. J.; Guzik, J. A.; Mussack, K. A.

    2016-05-01

    We present a new generation of Los Alamos OPLIB opacity tables that have been computed using the ATOMIC code. Our tables have been calculated for all 30 elements from hydrogen through zinc and are publicly available through our website. In this poster we discuss the details of the calculations that underpin the new opacity tables. We also show several recent applications of the use of our opacity tables to solar modeling and other astrophysical applications. In particular, we demonstrate that use of the new opacities improves the agreement between solar models and helioseismology, but does not fully resolve the long-standing `solar abundance' problem. The Los Alamos National Laboratory is operated by Los Alamos National Security, LLC for the National Nuclear Security Administration of the U.S. Department of Energy under Contract No. DE-AC5206NA25396.

  2. The neutrino opacity of neutron rich matter

    NASA Astrophysics Data System (ADS)

    Alcain, P. N.; Dorso, C. O.

    2017-05-01

    The study of neutron rich matter, present in neutron star, proto-neutron stars and core-collapse supernovae, can lead to further understanding of the behavior of nuclear matter in highly asymmetric nuclei. Heterogeneous structures are expected to exist in these systems, often referred to as nuclear pasta. We have carried out a systematic study of neutrino opacity for different thermodynamic conditions in order to assess the impact that the structure has on it. We studied the dynamics of the neutrino opacity of the heterogeneous matter at different thermodynamic conditions with semiclassical molecular dynamics model already used to study nuclear multifragmentation. For different densities, proton fractions and temperature, we calculate the very long range opacity and the cluster distribution. The neutrino opacity is of crucial importance for the evolution of the core-collapse supernovae and the neutrino scattering.

  3. Silicone intraocular lens surface calcification in a patient with asteroid hyalosis.

    PubMed

    Matsumura, Kazuhiro; Takano, Masahiko; Shimizu, Kimiya; Nemoto, Noriko

    2012-07-01

    To confirm a substance presence on the posterior intraocular lens (IOL) surface in a patient with asteroid hyalosis. An 80-year-old man had IOLs for approximately 12 years. Opacities and neodymium-doped yttrium aluminum garnet pits were observed on the posterior surface of the right IOL. Asteroid hyalosis and an epiretinal membrane were observed OD. An IOL exchange was performed on 24 March 2008, and the explanted IOL was analyzed using a light microscope and a transmission electron microscope with a scanning electron micrograph and an energy-dispersive X-ray spectrometer for elemental analysis. To confirm asteroid hyalosis, asteroid bodies were examined with the ionic liquid (EtMeIm+ BF4-) method using a field emission scanning electron microscope (FE-SEM) with digital beam control RGB mapping. X-ray spectrometry of the deposits revealed high calcium and phosphorus peaks. Spectrometry revealed that the posterior IOL surface opacity was due to a calcium-phosphorus compound. Examination of the asteroid bodies using FE-SEM with digital beam control RGB mapping confirmed calcium and phosphorus as the main components. Calcium hydrogen phosphate dihydrate deposits were probably responsible for the posterior IOL surface opacity. Furthermore, analysis of the asteroid bodies demonstrated that calcium and phosphorus were its main components.

  4. Free-free opacity in dense plasmas with an average atom model

    DOE PAGES

    Shaffer, Nathaniel R.; Ferris, Natalie G.; Colgan, James Patrick; ...

    2017-02-28

    A model for the free-free opacity of dense plasmas is presented. The model uses a previously developed average atom model, together with the Kubo-Greenwood model for optical conductivity. This, in turn, is used to calculate the opacity with the Kramers-Kronig dispersion relations. Furthermore, comparisons to other methods for dense deuterium results in excellent agreement with DFT-MD simulations, and reasonable agreement with a simple Yukawa screening model corrected to satisfy the conductivity sum rule.

  5. Free-free opacity in dense plasmas with an average atom model

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shaffer, Nathaniel R.; Ferris, Natalie G.; Colgan, James Patrick

    A model for the free-free opacity of dense plasmas is presented. The model uses a previously developed average atom model, together with the Kubo-Greenwood model for optical conductivity. This, in turn, is used to calculate the opacity with the Kramers-Kronig dispersion relations. Furthermore, comparisons to other methods for dense deuterium results in excellent agreement with DFT-MD simulations, and reasonable agreement with a simple Yukawa screening model corrected to satisfy the conductivity sum rule.

  6. The etiology of human age-related cataract. Proteins don't last forever.

    PubMed

    Truscott, Roger J W; Friedrich, Michael G

    2016-01-01

    It is probable that the great majority of human cataract results from the spontaneous decomposition of long-lived macromolecules in the human lens. Breakdown/reaction of long-lived proteins is of primary importance and recent proteomic analysis has enabled the identification of the particular crystallins, and their exact sites of amino acid modification. Analysis of proteins from cataractous lenses revealed that there are sites on some structural proteins that show a consistently greater degree of deterioration than age-matched normal lenses. The most abundant posttranslational modification of aged lens proteins is racemization. Deamidation, truncation and crosslinking, each arising from the spontaneous breakdown of susceptible amino acids within proteins, are also present. Fundamental to an understanding of nuclear cataract etiology, it is proposed that once a certain degree of modification at key sites occurs, that protein-protein interactions are disrupted and lens opacification ensues. Since long-lived proteins are now recognized to be present in many other sites of the body, such as the brain, the information gleaned from detailed analyses of degraded proteins from aged lenses will apply more widely to other age-related human diseases. This article is part of a Special Issue entitled Crystallin Biochemistry in Health and Disease. Copyright © 2015 Elsevier B.V. All rights reserved.

  7. SURGICAL INTERVENTION AND ACCOMMODATIVE RESPONSES: I. CENTRIPETAL CILIARY BODY, CAPSULE AND LENS MOVEMENT IN RHESUS MONKEYS OF VARYING AGE

    PubMed Central

    Croft, Mary Ann; Mcdonald, Jared P.; James, Rebecca J.; Heatley, Gregg A.; Lin, Ting-Li; Lütjen-Drecoll, Elke; Kaufman, Paul L.

    2009-01-01

    Purpose To determine how surgically altering the normal relationship between the lens and the ciliary body in rhesus monkeys affects centripetal ciliary body and lens movement. Methods In 18 rhesus monkey eyes (aged 6–27 years), accommodation was induced before and after surgery by electrical stimulation of the Edinger-Westphal (E–W) nucleus. Accommodative amplitude was measured by coincidence refractometry. Goniovideography was performed before and after intra- and extra-capsular lens extraction (ICLE, ECLE) and anterior regional zonulolysis. Centripetal lens/capsule movements, centripetal ciliary process (CP) movements, and circumlental space were measured by computerized image analysis of the goniovideography images. Results Centripetal accommodative CP and capsule movement increased in velocity and amplitude post-ECLE compared to pre-ECLE regardless of age (n=5). The presence of the lens substance retarded capsule movement by ~21% in the young eyes and by ~62% in the older eyes. Post-ICLE compared to pre-ICLE centripetal accommodative CP movement was dampened in all eyes in which the anterior vitreous was disturbed (n=7), but not in eyes in which the anterior vitreous was left intact (n=2). Following anterior regional zonulolysis (n=4), lens position shifted toward the lysed quadrant during accommodation. Conclusions The presence of the lens substance, capsule zonular attachments, and Wiegers ligament may play a role in centripetal CP movement. The capsule is still capable of centripetal movement in the older eye (although at a reduced capacity) and may have the ability to produce ~6 diopters of accommodation in the presence of a normal young crystalline lens or a similar surrogate. PMID:18552393

  8. Surgical intervention and accommodative responses, I: centripetal ciliary body, capsule, and lens movements in rhesus monkeys of various ages.

    PubMed

    Croft, Mary Ann; McDonald, Jared P; James, Rebecca J; Heatley, Gregg A; Lin, Ting-Li; Lütjen-Drecoll, Elke; Kaufman, Paul L

    2008-12-01

    To determine how surgically altering the normal relationship between the lens and the ciliary body in rhesus monkeys affects centripetal ciliary body and lens movement. In 18 rhesus monkey eyes (aged 6-27 years), accommodation was induced before and after surgery by electrical stimulation of the Edinger-Westphal nucleus. Accommodative amplitude was measured by coincidence refractometry. Goniovideography was performed before and after intra- and extracapsular lens extraction (ICLE, ECLE) and anterior regional zonulolysis (ARZ). Centripetal lens/capsule movements, centripetal ciliary process (CP) movements, and circumlental space were measured by computerized image analysis of the goniovideography images. Centripetal accommodative CP and capsule movement increased in velocity and amplitude after, compared with before, ECLE regardless of age (n = 5). The presence of the lens substance retarded capsule movement by approximately 21% in the young eyes and by approximately 62% in the older eyes. Post-ICLE compared with pre-ICLE centripetal accommodative CP movement was dampened in all eyes in which the anterior vitreous was disrupted (n = 7), but not in eyes in which the anterior vitreous was left intact (n = 2). After anterior regional zonulolysis (n = 4), lens position shifted toward the lysed quadrant during accommodation. The presence of the lens substance, capsule zonular attachments, and Wieger's ligament may play a role in centripetal CP movement. The capsule is still capable of centripetal movement in the older eye (although at a reduced capacity) and may have the ability to produce approximately 6 D of accommodation in the presence of a normal, young crystalline lens or a similar surrogate.

  9. Contact lens complications.

    PubMed

    Suchecki, Jeanine K; Donshik, Peter; Ehlers, William H

    2003-09-01

    Complications associated with contact lenses range from mild to severe and occur with all lens modalities. Contact lens wear can cause a change in corneal physiology, which can lead to epithelial, stromal, and endothelial compromise. Other complications include lens deposition, allergic conjunctivitis, giant papillary conjunctivitis, peripheral infiltrates, microbial keratitis, and neovascularization. Pre-existing conditions can contribute to these complications, or they can occur in association with contact lens wear and care regimens. Patient-related factors, such as alteration of the recommended wearing or replacement schedules and noncompliance with recommended contact lens care regimens for economic reasons, convenience, or in error, contribute to contact lens-related complications and have led to difficulty in accurate determination of complication rates among the various lens wear modalities. Complications may require discontinuation of contact lenses, topical therapy, and changes in contact lens wearing schedules, materials, and care solutions. On initial lens fitting and follow-up evaluations, practitioners should review contact lens replacement and cleaning regimens with patients and discuss complications. To avoid serious complications, patients should be reminded to remove their contact lenses as soon as ocular irritation occurs, and to call their eye care practitioner immediately if symptoms persist.

  10. Thermal Cyclotron Absorption Coefficients. II. Opacities in the Stokes Formalism

    NASA Astrophysics Data System (ADS)

    Vaeth, H. M.; Chanmugam, G.

    1995-05-01

    We extend the discussion of the calculation of the cyclotron opacities α± of the ordinary and extraordinary mode (Chanmugam et al.) to the opacities κ, q, υ in the Stokes formalism. We derive formulae with which a can be calculated from κ, q, υ. We are hence able to compare our calculations of the opacities, which are based on the single-particle method, with results obtained with the dielectric tensor method of Tam or. Excellent agreement is achieved. We present extensive tables of the opacities in the Stokes formalism for frequencies up to 25ωc, where ωc is the cyclotron frequency, and temperatures kT = 5, 10,20, 30,40, and 50 keV. Furthermore, we derive approximate formulae with which κ, q, υ can be calculated from α± and hence use the Robinson & Melrose analytic formulae for α± in order to calculate the opacities in the Stokes formalism. We compare these opacities to accurate numerical opacities and find that the analytic formulae can reproduce the qualitative behavior of the opacities in the regions where the harmonic structure is unimportant.

  11. The Role of Aquaporins in Ocular Lens Homeostasis

    PubMed Central

    Schey, Kevin L.; Petrova, Rosica S.; Gletten, Romell B.; Donaldson, Paul J.

    2017-01-01

    Aquaporins (AQPs), by playing essential roles in the maintenance of ocular lens homeostasis, contribute to the establishment and maintenance of the overall optical properties of the lens over many decades of life. Three aquaporins, AQP0, AQP1 and AQP5, each with distinctly different functional properties, are abundantly and differentially expressed in the different regions of the ocular lens. Furthermore, the diversity of AQP functionality is increased in the absence of protein turnover by age-related modifications to lens AQPs that are proposed to alter AQP function in the different regions of the lens. These regional differences in AQP functionality are proposed to contribute to the generation and directionality of the lens internal microcirculation; a system of circulating ionic and fluid fluxes that delivers nutrients to and removes wastes from the lens faster than could be achieved by passive diffusion alone. In this review, we present how regional differences in lens AQP isoforms potentially contribute to this microcirculation system by highlighting current areas of investigation and emphasizing areas where future work is required. PMID:29231874

  12. Relationship between changes in crystalline lens shape and axial elongation in young children.

    PubMed

    Ishii, Kotaro; Yamanari, Masahiro; Iwata, Hiroyoshi; Yasuno, Yoshiaki; Oshika, Tetsuro

    2013-01-28

    To evaluate the relationship between changes in crystalline lens shape and axial elongation during growth in young children. Twenty-five patients (age: 1 month to 6 years) who underwent head magnetic resonance imaging (MRI) were included in the analysis. Refractive error was measured with an autorefractor in 22 patients. Crystalline lens dimensions and axial length (AL) were obtained from the MR images. The radius of curvature and asphericity of the crystalline lens were measured using reconstructed MR images. Crystalline lens shape and eyeball shape were numerically expressed by elliptic Fourier descriptors (EFDs) on the basis of MR images. The contours of the crystalline lens and eyeball were evaluated by principal component analysis of the EFDs. The average anterior and posterior radii of curvature were 6.21 mm (range across ages from 3.89-7.26 mm) and -4.81 mm (range across ages from -2.93 to -5.67 mm). These were closely correlated with age by logarithmic analysis. The first principal component (PC1) of the crystalline lens explained 89.15% of the total variance in lens shape, and it was also significantly correlated with age (Pearson's r = 0.648, P < 0.001) and AL (r = 0.847, P < 0.001). In the multiple linear regression analysis in which AL was a dependent variable, only the PC1 of the crystalline lens was associated with AL. Axial elongation is related to the entire contour of the crystalline lens. This result shows that axial elongation progresses in parallel to change in the crystalline lens shape.

  13. A longitudinal study assessing lens thickness changes in the eye of the growing beagle using ultrasound scanning: relevance to age of dogs in regulatory toxicology studies.

    PubMed

    Maynard, Juliana; Sykes, Angela; Powell, Helen; Healing, Guy; Scott, Marietta; Holmes, Andrew; Ricketts, Sally-Ann; Stewart, Jane; Davis, Stewart

    2014-12-01

    The lens is formed in utero with new secondary lens fibres added as outer layers throughout life in a growth pattern characteristic of the species. This study examined the time course of beagle lens growth to better understand the optimal starting age of dogs for safety studies to support adult versus paediatric indications, and to assess the feasibility of non-invasively monitoring lens growth with high frequency ultrasound. Ultrasound scanning was performed in six female beagle dogs using the Vevo770. All dogs were imaged in B-mode using local anaesthetic but without sedation. Imaging was carried out every 2 weeks from 8 to 22 weeks of age and then monthly until 62 weeks of age. The dogs tolerated the procedure well. The lens was visible in all dogs and measuring the lens thickness with high frequency ultrasound demonstrated good analytical reproducibility [Root Mean Square (RMS) = 3.13%]. No differences between the left and right eye existed and lens thickness correlated with body weight. The highest weekly growth rate was before 12 weeks of age. A statistically significant difference between monthly thickness was detected until 42 weeks of age at which point growth reached a plateau. During the experiment, lenses grew by 29.7% reaching an average thickness of 6.4 mm ± 0.03. By 10 months of age (the typical age used for routine toxicological evaluation), beagles have reached a plateau in lens growth that is analogous to human adults. Where lens is a target organ of concern it is suggested that beagles under 6 months old may be a better model for determining paediatric safety. Copyright © 2014 John Wiley & Sons, Ltd.

  14. Computing NLTE Opacities -- Node Level Parallel Calculation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Holladay, Daniel

    Presentation. The goal: to produce a robust library capable of computing reasonably accurate opacities inline with the assumption of LTE relaxed (non-LTE). Near term: demonstrate acceleration of non-LTE opacity computation. Far term (if funded): connect to application codes with in-line capability and compute opacities. Study science problems. Use efficient algorithms that expose many levels of parallelism and utilize good memory access patterns for use on advanced architectures. Portability to multiple types of hardware including multicore processors, manycore processors such as KNL, GPUs, etc. Easily coupled to radiation hydrodynamics and thermal radiative transfer codes.

  15. Detailed opacity calculations for stellar models

    NASA Astrophysics Data System (ADS)

    Pain, Jean-Christophe; Gilleron, Franck

    2016-10-01

    We present a state of the art of precise spectral opacity calculations illustrated by stellar applications. The essential role of laboratory experiments to check the quality of the computed data is underlined. We review some X-ray and XUV laser and Z-pinch photo-absorption measurements as well as X-ray emission spectroscopy experiments of hot dense plasmas produced by ultra-high-intensity laser interaction. The measured spectra are systematically compared with the fine-structure opacity code SCO-RCG. Focus is put on iron, due to its crucial role in the understanding of asteroseismic observations of Beta Cephei-type and Slowly Pulsating B stars, as well as in the Sun. For instance, in Beta Cephei-type stars (which should not be confused with Cepheid variables), the iron-group opacity peak excites acoustic modes through the kappa-mechanism. A particular attention is paid to the higher-than-predicted iron opacity measured on Sandia's Z facility at solar interior conditions (boundary of the convective zone). We discuss some theoretical aspects such as orbital relaxation, electron collisional broadening, ionic Stark effect, oscillator-strength sum rules, photo-ionization, or the ``filling-the-gap'' effect of highly excited states.

  16. OPserver: opacities and radiative accelerations on demand

    NASA Astrophysics Data System (ADS)

    Mendoza, C.; González, J.; Seaton, M. J.; Buerger, P.; Bellorín, A.; Meléndez, M.; Rodríguez, L. S.; Delahaye, F.; Zeippen, C. J.; Palacios, E.; Pradhan, A. K.

    2009-05-01

    We report on developments carried out within the Opacity Project (OP) to upgrade atomic database services to comply with e-infrastructure requirements. We give a detailed description of an interactive, online server for astrophysical opacities, referred to as OPserver, to be used in sophisticated stellar modelling where Rosseland mean opacities and radiative accelerations are computed at every depth point and each evolution cycle. This is crucial, for instance, in chemically peculiar stars and in the exploitation of the new asteroseismological data. OPserver, downloadable with the new OPCD_3.0 release from the Centre de Données Astronomiques de Strasbourg, France, computes mean opacities and radiative data for arbitrary chemical mixtures from the OP monochromatic opacities. It is essentially a client-server network restructuring and optimization of the suite of codes included in the earlier OPCD_2.0 release. The server can be installed locally or, alternatively, accessed remotely from the Ohio Supercomputer Center, Columbus, Ohio, USA. The client is an interactive web page or a subroutine library that can be linked to the user code. The suitability of this scheme in grid computing environments is emphasized, and its extension to other atomic database services for astrophysical purposes is discussed.

  17. Serendipity and Holism: The Beauty of OPACs.

    ERIC Educational Resources Information Center

    Rice, James

    1988-01-01

    Identifies factors which may account for user dissatisfaction with online public access catalogs (OPACs) and discusses some advantages of OPACs over card catalogs: (1) design for subject searching; (2) flexibility; (3) browsing capability; (4) precision; (5) availability of status information; and (6) development of microcomputer software to…

  18. Relationship between relative lens position and appositional closure in eyes with narrow angles.

    PubMed

    Otori, Yasumasa; Tomita, Yuki; Hamamoto, Ayumi; Fukui, Kanae; Usui, Shinichi; Tatebayashi, Misako

    2011-03-01

    To investigate the relationship between relative lens position (RLP) and appositional closure in eyes with narrow angles. Ultrasound biomicroscopy (UBM) was used to measure anterior chamber depth (ACD) and lens thickness (LT), and the IOLMaster to measure axial length (AL). The number of quadrants with appositional closure was assessed by UBM under dark conditions. The RLP was calculated thus: RLP = 10 × (ACD + 0.5 LT) /AL. This study comprised 30 consecutive patients (30 eyes) with narrow-angle eyes defined as Shaffer grade 2 or lower and without peripheral anterior synechiae (24 women, 6 men; mean age ± SD, 67.3 ± 10.4 years; range, 42-87 years). Under dark conditions, 66.7% of the eyes with narrow angles showed appositional closure in at least one quadrant. Of the various ocular biometric parameters, only the RLP significantly decreased with appositional closure in at least one quadrant (P = 0.005). A decrease in the RLP can be predictive of appositional closure for narrow-angle eyes under dark conditions.

  19. NLTE opacity calculations: C-Si and C-Ge mixtures

    NASA Astrophysics Data System (ADS)

    Jarrah, W.; Benredjem, D.; Pain, J.-C.; Dubau, J.

    2017-09-01

    The opacity is an important issue in the knowledge of the radiative properties of ICF and astrophysical plasmas. We present the opacity of dopants (silicon, germanium) embedded in the ablator of some ICF capsules. In recent works, Hill and Rose calculated the opacity of silicon in LTE and non-LTE plasmas, while Minguez and co-workers focused on the opacity of carbon. We have used the Cowan code to calculate the atomic structure of carbon, silicon and germanium in various ionic stages. The cross-sections of atomic processes (collisional excitation, collisional ionization) are obtained by fitting the values given by the code FAC to the Van Regemorter-like formulas of Sampson and Zhang. A corrected Gaunt factor is then obtained. A collisional-radiative code was developed in order to obtain the ionic populations, the level populations and the opacity. Line broadening and line shift are taken into account. The ionization potential depression is included in our calculations. The effect of a radiation field on the opacity is examined.

  20. X ray opacity in cluster cooling flows

    NASA Technical Reports Server (NTRS)

    Wise, Michael W.; Sarazin, Craig L.

    1993-01-01

    We have calculated the emergent x-ray properties for a set of spherically symmetric, steady-state cluster cooling flow models including the effects of radiative transfer. Opacity due to resonant x-ray lines, photoelectric absorption, and electron scattering have been included in these calculations, and homogeneous and inhomogeneous gas distributions were considered. The effects of photoionization opacity are small for both types of models. In contrast, resonant line optical depths can be quite high in both homogeneous and inhomogeneous models. The presence of turbulence in the gas can significantly lower the line opacity. We find that integrated x-ray spectra for the flow cooling now are only slightly affected by radiative transfer effects. However x-ray line surface brightness profiles can be dramatically affected by radiative transfer. Line profiles are also strongly affected by transfer effects. The combined effects of opacity and inflow cause many of the lines in optically thick models to be asymmetrical.

  1. Quantitative evaluation of light scattering intensities of the crystalline lens for radiation related minimal change in interventional radiologists: a cross-sectional pilot study.

    PubMed

    Abe, Toshi; Furui, Shigeru; Sasaki, Hiroshi; Sakamoto, Yasuo; Suzuki, Shigeru; Ishitake, Tatsuya; Terasaki, Kinuyo; Kohtake, Hiroshi; Norbash, Alexander M; Behrman, Richard H; Hayabuchi, Naofumi

    2013-03-01

    To evaluate low-dose X-ray radiation effects on the eye by measuring the amount of light scattering in specific regions of the lens, we compared exposed subjects (interventional radiologists) with unexposed subjects (employees of medical service companies), as a pilot study. According to numerous exclusionary rules, subjects with confounding variables contributing to cataract formation were excluded. Left eye examinations were performed on 68 exposed subjects and 171 unexposed subjects. The eye examinations consisted of an initial screening examination, followed by Scheimpflug imaging of the lens using an anterior eye segment analysis system. The subjects were assessed for the quantity of light scattering intensities found in each of the six layers of the lens. Multiple stepwise regression analyses were performed with the stepwise regression for six variables: age, radiation exposure, smoking, drinking, wearing glasses and workplace. In addition, an age-matched comparison between exposed and unexposed subjects was performed. Minimal increased light scattering intensity in the posterior subcapsular region showed statistical significance. Our results indicate that occupational radiation exposure in interventional radiologists may affect the posterior subcapsular region of the lens. Since by its very nature this retrospective study had many limitations, further well-designed studies concerning minimal radiation-related lens changes should be carried out in a low-dose exposure group.

  2. E-Referencer: Transforming Boolean OPACs to Web Search Engines.

    ERIC Educational Resources Information Center

    Khoo, Christopher S. G.; Poo, Danny C. C.; Toh, Teck-Kang; Hong, Glenn

    E-Referencer is an expert intermediary system for searching library online public access catalogs (OPACs) on the World Wide Web. It is implemented as a proxy server that mediates the interaction between the user and Boolean OPACs. It transforms a Boolean OPAC into a retrieval system with many of the search capabilities of Web search engines.…

  3. Predicting cattle age from eye lens weight and nitrogen content, dentition, and United States Department of Agriculture maturity score.

    PubMed

    Raines, C R; Dikeman, M E; Unruh, J A; Hunt, M C; Knock, R C

    2008-12-01

    This research explores the relationship between generally accepted and alternative cattle age-prediction methods and chronological age. Cattle (n = 386) of documented ages ranging from 370 to 1,115 d of age were used. Dentition (DEN), USDA maturity score (MS), lens weight (LW), and lens total N (LN) content were used as possible predictors of age. Correlations with age were determined: LW (r = 0.77); DEN (r = 0.74); LN (r = 0.71); and MS (r = 0.64). Stepwise backward regression was used to generate an age prediction equation: Age (mo) = -21.79 + 17.23(LW, g) + 0.038(DEN). By this equation, 38% of cattle age were verified as age. Independent measures verified the following percentages of cattle as age: LW (20.2%), MS (11.0%), DEN (9.6%), and LN (8.7%). The DEN verified that 87.6% were verified as <30 mo old, and LW verified 81.6% of cattle as <30 mo old. A separate group of cattle (n = 18) ranging in age from 1 to 12 yr were evaluated for lens properties, for which LW (R(2) = 0.91) and LN (R(2) = 0.92) were highly correlated with age. The LW and DEN were the best predictors of age for cattle 13- to 37-mo-old and yielded the most accurate age prediction when used in combination (R(2) = 0.67).

  4. Are Older Adults Less Embodied? A Review of Age Effects through the Lens of Embodied Cognition

    PubMed Central

    Costello, Matthew C.; Bloesch, Emily K.

    2017-01-01

    Embodied cognition is a theoretical framework which posits that cognitive function is intimately intertwined with the body and physical actions. Although the field of psychology is increasingly accepting embodied cognition as a viable theory, it has rarely been employed in the gerontological literature. However, embodied cognition would appear to have explanatory power for aging research given that older adults typically manifest concurrent physical and mental changes, and that research has indicated a correlative relationship between such changes. The current paper reviews age-related changes in sensory processing, mental representation, and the action-perception relationship, exploring how each can be understood through the lens of embodied cognition. Compared to younger adults, older adults exhibit across all three domains an increased tendency to favor visual processing over bodily factors, leading to the conclusion that older adults are less embodied than young adults. We explore the significance of this finding in light of existing theoretical models of aging and argue that embodied cognition can benefit gerontological research by identifying further factors that can explain the cause of age-related declines. PMID:28289397

  5. Impact of Neutrino Opacities on Core-collapse Supernova Simulations

    NASA Astrophysics Data System (ADS)

    Kotake, Kei; Takiwaki, Tomoya; Fischer, Tobias; Nakamura, Ko; Martínez-Pinedo, Gabriel

    2018-02-01

    The accurate description of neutrino opacities is central to both the core-collapse supernova (CCSN) phenomenon and the validity of the explosion mechanism itself. In this work, we study in a systematic fashion the role of a variety of well-selected neutrino opacities in CCSN simulations where the multi-energy, three-flavor neutrino transport is solved using the isotropic diffusion source approximation (IDSA) scheme. To verify our code, we first present results from one-dimensional (1D) simulations following the core collapse, bounce, and ∼250 ms postbounce of a 15 {M}ȯ star using a standard set of neutrino opacities by Bruenn. A detailed comparison with published results supports the reliability of our three-flavor IDSA scheme using the standard opacity set. We then investigate in 1D simulations how individual opacity updates lead to differences with the baseline run with the standard opacity set. Through detailed comparisons with previous work, we check the validity of our implementation of each update in a step-by-step manner. Individual neutrino opacities with the largest impact on the overall evolution in 1D simulations are selected for systematic comparisons in our two-dimensional (2D) simulations. Special attention is given to the criterion of explodability in the 2D models. We discuss the implications of these results as well as its limitations and the requirements for future, more elaborate CCSN modeling.

  6. Aberrant Epigenetic Alterations of Glutathione-S-Transferase P1 in Age-Related Nuclear Cataract.

    PubMed

    Chen, Jia; Zhou, Jing; Wu, Jian; Zhang, Guowei; Kang, Lihua; Ben, Jindong; Wang, Yong; Qin, Bai; Guan, Huaijin

    2017-03-01

    Oxidative damage of lens tissue contributes to the formation of age-related cataract. Pi-class glutathione-S-transferase (GSTP1) plays a role in the removal of oxidative adducts by transferring them to glutathione. To assess epigenetic regulation of GSTP1 and its potential role in age-related nuclear cataract (ARNC) pathogenesis, we evaluated GSTP1 mRNA expression, methylation, and chromatin modifications in lenses from ARNC patients. The mRNA and protein of lens GSTP1 were assayed by relative quantitative real-time polymerase chain reaction (qRT-PCR) and Western blots. Methylation of the GSTP1 promoter was determined by bisulfite genomic sequencing. Chromatin modification was detected by chromatin immunoprecipitation. DNA methyltransferase (DNMT) and histone deacetylase (HDAC) activities were also assayed by enzyme-linked immunosorbent assay (ELISA)-like reaction. To assess the effect of DNA methylation on the mRNA expression of GSTP1, human lens epithelium HLE-B3 cells were treated with the demethylation compound 5-aza-dC, followed by qRT-PCR assay. GSTP1 mRNA and protein levels were significantly reduced in lens epithelium and cortex of ARNC cases versus age-matched controls. The changes corresponded to hypermethylation of the GSTP1 promoter CpG islands. The loss of GSTP1 mRNA and protein and the increased DNA promoter methylation might be correlated with the severity of the ARNC. ARNC lenses also had lower acetylation of histone proteins H3, H4, and lower methylation of H3K4, and higher methylation of H3K9. Histone modifications were not correlated with the severity of the ARNCs. DNMT and HDAC were elevated in lenses from ARNCs compared with controls. Demethylation treatment of HLE-B3 cells with 5-aza-dC enhanced the expression of GSTP1. Epigenetic alteration of GSTP1 regulates its expression in lens epithelial and cortical tissues. These changes likely contribute to the pathogenesis of ARNC.

  7. Investigating the Effect of Cosmic Opacity on Standard Candles

    NASA Astrophysics Data System (ADS)

    Hu, J.; Yu, H.; Wang, F. Y.

    2017-02-01

    Standard candles can probe the evolution of dark energy over a large redshift range. But the cosmic opacity can degrade the quality of standard candles. In this paper, we use the latest observations, including Type Ia supernovae (SNe Ia) from the “joint light-curve analysis” sample and Hubble parameters, to probe the opacity of the universe. A joint fitting of the SNe Ia light-curve parameters, cosmological parameters, and opacity is used in order to avoid the cosmological dependence of SNe Ia luminosity distances. The latest gamma-ray bursts are used in order to explore the cosmic opacity at high redshifts. The cosmic reionization process is considered at high redshifts. We find that the sample supports an almost transparent universe for flat ΛCDM and XCDM models. Meanwhile, free electrons deplete photons from standard candles through (inverse) Compton scattering, which is known as an important component of opacity. This Compton dimming may play an important role in future supernova surveys. From analysis, we find that about a few per cent of the cosmic opacity is caused by Compton dimming in the two models, which can be corrected.

  8. Investigating the Effect of Cosmic Opacity on Standard Candles

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hu, J.; Yu, H.; Wang, F. Y., E-mail: fayinwang@nju.edu.cn

    Standard candles can probe the evolution of dark energy over a large redshift range. But the cosmic opacity can degrade the quality of standard candles. In this paper, we use the latest observations, including Type Ia supernovae (SNe Ia) from the “joint light-curve analysis” sample and Hubble parameters, to probe the opacity of the universe. A joint fitting of the SNe Ia light-curve parameters, cosmological parameters, and opacity is used in order to avoid the cosmological dependence of SNe Ia luminosity distances. The latest gamma-ray bursts are used in order to explore the cosmic opacity at high redshifts. The cosmicmore » reionization process is considered at high redshifts. We find that the sample supports an almost transparent universe for flat ΛCDM and XCDM models. Meanwhile, free electrons deplete photons from standard candles through (inverse) Compton scattering, which is known as an important component of opacity. This Compton dimming may play an important role in future supernova surveys. From analysis, we find that about a few per cent of the cosmic opacity is caused by Compton dimming in the two models, which can be corrected.« less

  9. Identification of the in vivo truncation sites at the C-terminal region of alpha-A crystallin from aged bovine and human lens

    NASA Technical Reports Server (NTRS)

    Takemoto, L. J.; Spooner, B. S. (Principal Investigator)

    1995-01-01

    Total alpha-A crystallin was purified from young versus old lens, followed by digestion with cyanogen bromide. Laser desorption mass spectrometry of the C-terminal fragment demonstrated age-dependent loss of one and five amino acids from the C-terminus of alpha-A crystallin from both bovine and human lens. These results demonstrate specific peptide bonds of alpha-A crystallin are cleaved during the aging process of the normal lens. The C-terminal region is cleaved in two places between the two hydroxyl-containing amino acids present in the sequence -P-S(T)-S-.

  10. Phenotype-genotype correlation in potential female carriers of X-linked developmental cataract (Nance-Horan syndrome).

    PubMed

    Khan, Arif O; Aldahmesh, Mohammed A; Mohamed, Jawahir Y; Alkuraya, Fowzan S

    2012-06-01

    To correlate clinical examination with underlying genotype in asymptomatic females who are potential carriers of X-linked developmental cataract (Nance-Horan syndrome). An ophthalmologist blind to the pedigree performed comprehensive ophthalmic examination for 16 available family members (two affected and six asymptomatic females, five affected and three asymptomatic males). Facial features were also noted. Venous blood was collected for sequencing of the gene NHS. All seven affected family members had congenital or infantile cataract and facial dysmorphism (long face, bulbous nose, abnormal dentition). The six asymptomatic females ranged in age from 4-35 years old. Four had posterior Y-suture centered lens opacities; these four also exhibited the facial dysmorphism of the seven affected family members. The fifth asymptomatic girl had scattered fine punctate lens opacities (not centered on the Y-suture) while the sixth had clear lenses, and neither exhibited the facial dysmorphism. A novel NHS mutation (p.Lys744AsnfsX15 [c.2232delG]) was found in the seven patients with congenital or infantile cataract. This mutation was also present in the four asymptomatic girls with Y-centered lens opacities but not in the other two asymptomatic girls or in the three asymptomatic males (who had clear lenses). Lens opacities centered around the posterior Y-suture in the context of certain facial features were sensitive and specific clinical signs of carrier status for NHS mutation in asymptomatic females. Lens opacities that did not have this characteristic morphology in a suspected female carrier were not a carrier sign, even in the context of her affected family members.

  11. More missing stellar opacity?

    NASA Technical Reports Server (NTRS)

    Stothers, Richard B.; Chin, Chao-Wen

    1994-01-01

    Observational data for Population I stars have shown that blue loops on the Hertzsprung-Russell (H-R) diagram form for stellar masses as low as approximately 4 solar mass. However, current state-of-the-art stellar models, unlike the older ones that were based on smaller opacities, fail to loop out of the red-giant region during core helium burning for masses less than 7 solar mass. A possible explanation is that the currently used Livermore opacities need to be further increased, by at least 70%, at temperatures characteristic of the base of the outer convection zone, around 1 x 10(exp 6) K. Indeed, no other suggested remedy seems to yield a blue loop at the lowest observed loop luminosities.

  12. Nanoceria have no genotoxic effect on human lens epithelial cells

    NASA Astrophysics Data System (ADS)

    Pierscionek, Barbara K.; Li, Yuebin; Yasseen, Akeel A.; Colhoun, Liza M.; Schachar, Ronald A.; Chen, Wei

    2010-01-01

    There are no treatments for reversing or halting cataract, a disease of the structural proteins in the eye lens, that has associations with other age-related degenerative conditions such as Alzheimer's disease. The incidence of cataract and associated conditions is increasing as the average age of the population rises. Protein folding diseases are difficult to assess in vivo as proteins and their age-related changes are assessed after extraction. Nanotechnology can be used to investigate protein changes in the intact lens as well as for a potential means of drug delivery. Nanoparticles, such as cerium oxide (CeO2) which have antioxidant properties, may even be used as a means of treating cataract directly. Prior to use in treatments, nanoparticle genotoxicity must be tested to assess the extent of any DNA or chromosomal damage. Sister chromatid exchanges were measured and DNA damage investigated using the alkaline COMET assay on cultured human lens epithelial cells, exposed to 5 and 10 µg ml-1 of CeO2 nanoparticles (nanoceria). Nanoceria at these dosages did not cause any DNA damage or significant increases in the number of sister chromatid exchanges. The absence of genotoxic effects on lens cells suggests that nanoceria, in the doses and exposures tested in this study, are not deleterious to the eye lens and have the potential for use in studying structural alterations, in developing non-surgical cataract treatments and in investigating other protein folding diseases.

  13. Model-independent Constraints on Cosmic Curvature and Opacity

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, Guo-Jian; Li, Zheng-Xiang; Xia, Jun-Qing

    2017-09-20

    In this paper, we propose to estimate the spatial curvature of the universe and the cosmic opacity in a model-independent way with expansion rate measurements, H ( z ), and type Ia supernova (SNe Ia). On the one hand, using a nonparametric smoothing method Gaussian process, we reconstruct a function H ( z ) from opacity-free expansion rate measurements. Then, we integrate the H ( z ) to obtain distance modulus μ {sub H}, which is dependent on the cosmic curvature. On the other hand, distances of SNe Ia can be determined by their photometric observations and thus are opacity-dependent.more » In our analysis, by confronting distance moduli μ {sub H} with those obtained from SNe Ia, we achieve estimations for both the spatial curvature and the cosmic opacity without any assumptions for the cosmological model. Here, it should be noted that light curve fitting parameters, accounting for the distance estimation of SNe Ia, are determined in a global fit together with the cosmic opacity and spatial curvature to get rid of the dependence of these parameters on cosmology. In addition, we also investigate whether the inclusion of different priors for the present expansion rate ( H {sub 0}: global estimation, 67.74 ± 0.46 km s{sup −1} Mpc{sup −1}, and local measurement, 73.24 ± 1.74 km s{sup −1} Mpc{sup −1}) exert influence on the reconstructed H ( z ) and the following estimations of the spatial curvature and cosmic opacity. Results show that, in general, a spatially flat and transparent universe is preferred by the observations. Moreover, it is suggested that priors for H {sub 0} matter a lot. Finally, we find that there is a strong degeneracy between the curvature and the opacity.« less

  14. Assessment of tilt and decentration of crystalline lens and intraocular lens relative to the corneal topographic axis using anterior segment optical coherence tomography

    PubMed Central

    Morizane, Yuki; Shiode, Yusuke; Hirano, Masayuki; Doi, Shinichiro; Toshima, Shinji; Fujiwara, Atsushi; Shiraga, Fumio

    2017-01-01

    Purpose To investigate the tilt and decentration of the crystalline lens and the intraocular lens (IOL) relative to the corneal topographic axis using anterior segment ocular coherence tomography (AS-OCT). Methods A sample set of 100 eyes from 49 subjects (41 eyes with crystalline lenses and 59 eyes with IOLs) were imaged using second generation AS-OCT (CASIA2, TOMEY) in June and July 2016 at Okayama University. Both mydriatic and non-mydriatic images were obtained, and the tilt and decentration of the crystalline lens and the IOL were quantified. The effects of pupil dilation on measurements were also assessed. Results The crystalline lens showed an average tilt of 5.15° towards the inferotemporal direction relative to the corneal topographic axis under non-mydriatic conditions and 5.25° under mydriatic conditions. Additionally, an average decentration of 0.11 mm towards the temporal direction was observed under non-mydriatic conditions and 0.08 mm under mydriatic conditions. The average tilt for the IOL was 4.31° towards the inferotemporal direction relative to the corneal topographic axis under non-mydriatic conditions and 4.65° in the same direction under mydriatic conditions. The average decentration was 0.05 mm towards the temporal direction under non-mydriatic conditions and 0.08 mm in the same direction under mydriatic conditions. A strong correlation was found between the average tilt and decentration values of the crystalline lens and the IOL under both non-mydriatic and mydriatic conditions (all Spearman correlation coefficients, r ≥ 0.800; all P < 0.001). Conclusion When measured using second generation AS-OCT, both the crystalline lens and the IOL showed an average tilt of 4–6° toward the inferotemporal direction relative to the corneal topographic axis and an average decentration of less than 0.12 mm towards the temporal direction. These results were not influenced by pupil dilation and they showed good repeatability. PMID:28863141

  15. Assessment of tilt and decentration of crystalline lens and intraocular lens relative to the corneal topographic axis using anterior segment optical coherence tomography.

    PubMed

    Kimura, Shuhei; Morizane, Yuki; Shiode, Yusuke; Hirano, Masayuki; Doi, Shinichiro; Toshima, Shinji; Fujiwara, Atsushi; Shiraga, Fumio

    2017-01-01

    To investigate the tilt and decentration of the crystalline lens and the intraocular lens (IOL) relative to the corneal topographic axis using anterior segment ocular coherence tomography (AS-OCT). A sample set of 100 eyes from 49 subjects (41 eyes with crystalline lenses and 59 eyes with IOLs) were imaged using second generation AS-OCT (CASIA2, TOMEY) in June and July 2016 at Okayama University. Both mydriatic and non-mydriatic images were obtained, and the tilt and decentration of the crystalline lens and the IOL were quantified. The effects of pupil dilation on measurements were also assessed. The crystalline lens showed an average tilt of 5.15° towards the inferotemporal direction relative to the corneal topographic axis under non-mydriatic conditions and 5.25° under mydriatic conditions. Additionally, an average decentration of 0.11 mm towards the temporal direction was observed under non-mydriatic conditions and 0.08 mm under mydriatic conditions. The average tilt for the IOL was 4.31° towards the inferotemporal direction relative to the corneal topographic axis under non-mydriatic conditions and 4.65° in the same direction under mydriatic conditions. The average decentration was 0.05 mm towards the temporal direction under non-mydriatic conditions and 0.08 mm in the same direction under mydriatic conditions. A strong correlation was found between the average tilt and decentration values of the crystalline lens and the IOL under both non-mydriatic and mydriatic conditions (all Spearman correlation coefficients, r ≥ 0.800; all P < 0.001). When measured using second generation AS-OCT, both the crystalline lens and the IOL showed an average tilt of 4-6° toward the inferotemporal direction relative to the corneal topographic axis and an average decentration of less than 0.12 mm towards the temporal direction. These results were not influenced by pupil dilation and they showed good repeatability.

  16. Autophagy and UPR in alpha-crystallin mutant knock-in mouse models of hereditary cataracts.

    PubMed

    Andley, Usha P; Goldman, Joshua W

    2016-01-01

    Knock-in mice provide useful models of congenital and age-related cataracts caused by α-crystallin mutations. R49C αA-crystallin and R120G αB-crystallin mutations are linked with hereditary cataracts. Knock-in αA-R49C+/- heterozygotes develop cataracts by 1-2months, whereas homozygote mice have cataracts at birth. The R49C mutation drastically reduces lens protein water solubility and causes cell death in knock-in mouse lenses. Mutant crystallin cannot function as a chaperone, which leads to protein aggregation and lens opacity. Protein aggregation disrupts the lens fiber cell structure and normal development and causes cell death in epithelial and fiber cells. We determined what aspects of the wild-type phenotype are age-dependently altered in the mutant lens. Wild-type, heterozygote (αA-R49C+/-), and homozygote (αA-R49C+/+) mouse lenses were assessed pre- and postnatally for lens morphology (electron microscopy, immunohistochemistry), and autophagy or unfolded protein response markers (immunoblotting). Morphology was altered by embryonic day 17 in R49C+/+ lenses; R49C+/- lens morphology was unaffected at this stage. Active autophagy in the lens epithelium of mutant lenses was indicated by the presence of autophagosomes using electron microscopy. Protein p62 levels, which are degraded specifically by autophagy, increased in αA-R49C mutant versus wild-type lenses, suggesting autophagy inhibition in the mutant lenses. The unfolded protein response marker XBP-1 was upregulated in adult lenses of αB-R120G+/+ mice, suggesting its role in lens opacification. Mutated crystallins alter lens morphology, autophagy, and stress responses. Therapeutic modulation of autophagic pathways may improve protein degradation in cataractous lenses and reduce lens opacity. This article is part of a Special Issue entitled Crystallin Biochemistry in Health and Disease. Copyright © 2015 Elsevier B.V. All rights reserved.

  17. Long-Term Visual Outcomes of Secondary Intraocular Lens Implantation in Children with Congenital Cataracts

    PubMed Central

    Jiang, Yongxiang; Lu, Yi

    2015-01-01

    Aim The aim of this study was to evaluate the long-term visual outcomes and factors affecting visual results in children undergoing secondary intraocular lens (IOL) implantation following primary congenital cataract extraction. Methods Children with congenital cataracts who underwent secondary IOL implantation for aphakia at the Eye and ENT Hospital of Fudan University between January 1, 2001, and December 31, 2007, were retrospectively reviewed. One eye was randomly selected in children with bilateral cataracts. Laterality, type of cataract (total or partial opacity), sex, age at primary and secondary surgeries, visual axis opacity (VAO), compliance with amblyopia therapy, postoperative ocular complications, refractive error, ocular alignment, and best corrected visual acuity (BCVA) at last follow-up were recorded; potential factors that might have affected the visual results were evaluated. Results Seventy-six bilateral and 34 unilateral congenital cataract cases were analyzed; the mean ages of the children were 12.70±5.06 and 12.50±2.71 years at final follow-up, the mean follow-up periods from IOL implantation were 94.93±24.22 and 109.09±18.89 months, and the mean BCVA (Log MAR) values were 0.51±0.37 and 1.05±0.46, respectively. Final BCVA after secondary IOL implantation was significantly associated with laterality, type of cataract, age at primary cataract extraction, compliance with amblyopia therapy, and refractive correction after surgery. No significant associations were found between BCVA and sex, age at secondary IOL implantation, VAO, or other ocular complications. The most common ocular complications were VAO and elevated intraocular pressure after surgery. There were no other complications, with the exception of one eye with IOL dislocation. Conclusions The results indicate that the important determinants of long-term visual outcomes in children with congenital cataracts undergoing secondary IOL implantation are laterality, cataract type, age at

  18. Post-lens tear turbidity and visual quality after scleral lens wear.

    PubMed

    Carracedo, Gonzalo; Serramito-Blanco, Maria; Martin-Gil, Alba; Wang, Zicheng; Rodriguez-Pomar, Candela; Pintor, Jesús

    2017-11-01

    The aim was to evaluate the turbidity and thickness of the post-lens tear layer and its effect on visual quality in patients with keratoconus after the beginning of lens wear and before lens removal at the end of eight hours. Twenty-six patients with keratoconus (aged 36.95 ± 8.95 years) participated voluntarily in the study. The sample was divided into two groups: patients with intrastromal corneal ring (ICRS group) and patients without ICRS (KC group). Distance visual acuity (VA), contrast sensitivity, pachymetry, post-lens tear layer height and post-lens tear layer turbidity (percentage area occupied and number of particles per mm 2 ) were evaluated with optical coherence tomography before and after wearing a scleral lens. A significant increase of turbidity was found in all groups assessed (p < 0.05). The number of particles per square millimetre was eight times higher after scleral lens wear than at the beginning of wearing the lens for all groups. VA decreases in all groups after scleral lens wear (p < 0.001). All patients showed a statistical diminishing of contrast sensitivity after scleral lens wear (p < 0.05). A significant correlation was found for both turbidity parameters with distance VA but no correlation between turbidity and post-lens tear layer thickness at the beginning was found (p > 0.05). A strong correlation in all groups between the post-lens tear layer at the beginning and differences of tear layer thickness between two measures was also found (p < 0.05). The VA decrease during the scleral lens wearing, filled with preserved saline solution, was due to the increasing post-lens tear layer turbidity. © 2017 Optometry Australia.

  19. Combined laser-ray tracing and OCT system for biometry of the crystalline lens (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Ruggeri, Marco; Maceo Heilman, Bianca M.; Yao, Yue; Chang, Yu-Cherng; Gonzalez, Alex; Rowaan, Cornelis; Mohamed, Ashik; Williams, Siobhan; Durkee, Heather A.; Silgado, Juan; Bernal, Andres; Arrieta-Quintero, Esdras; Ho, Arthur; Parel, Jean-Marie A.; Manns, Fabrice

    2017-02-01

    Age-related changes in the crystalline lens shape and refractive index gradient produce changes in dioptric power and high-order aberrations that influence the optics of the whole eye and contribute to a decrease in overall visual quality. Despite their key role, the changes in lens shape and refractive index gradient with age and accommodation and their effects on high-order aberrations are still not well understood. The goal of this project was to develop a combined laser ray tracing (LRT) and optical coherence tomography (OCT) system to measure high-order aberrations, shape and refractive index gradient in non-human primate and human lenses. A miniature motorized lens stretching system was built to enable imaging and aberrometry of the lens during simulated accommodation. A positioning system was also built to enable on- and off-axis OCT imaging and aberrometry for characterization of the peripheral defocus of the lens. We demonstrated the capability of the LRT-OCT system to produce OCT images and aberration measurements of crystalline lens with age and accommodation in vitro. In future work, the information acquired with the LRT-OCT system will be used to develop an accurate age-dependent lens model to predict the role of the lens in the development of refractive error and aberrations of the whole eye.

  20. The clinical and cellular basis of contact lens-related corneal infections

    PubMed Central

    Robertson, Danielle M; Cavanagh, H Dwight

    2008-01-01

    Microbial keratitis (MK) is the most visually devastating complication associated with contact lens wear. Pseudomonas aeruginosa (PA) is highly invasive in the corneal epithelium and is responsible for more than half of the reported cases of contact lens-related MK. To protect against Pseudomonas-mediated MK, the corneal epithelium has evolved overlapping defense mechanisms that function to protect the ocular surface from microbial invasion. Research has shown that contact lens wear disrupts these protective mechanisms through breakdown of normal homeostatic surface renewal as well as damaging the corneal surface, exposing underlying cell membrane receptors that bind and internalize PA through the formation of lipid rafts. Human clinical trials have shown that initial adherence of PA with resulting increased risk for microbial infection is mediated in part by contact lens oxygen transmissibility. Recently, chemical preserved multipurpose solutions (MPS) have been implicated in increasing PA adherence to corneal epithelial cells, in addition to inducing significant levels of toxic staining when used in conjunction with specific silicone hydrogel lenses. This review summarizes what is currently known about the relationship between contact lenses, the corneal epithelium, MPS, and infection. PMID:19277209

  1. [The "light" water effect on lenticular opacity development in mice after repeated low dose gamma-irradiation].

    PubMed

    Abrosimova, A N; Rakov, D V; Siniak, Iu E

    2009-01-01

    Action of "light" water with reduced quantities of heavy stable hydrogen and 18O ions on incidence and progress of lenticular opacity was studied in gamma-irradiated mice (60Co, 1.0 Gy). The animals were subjected to electroophthalmoscopy regularly till end of life time. The observation showed that chronic intake of "light" water safeguarded the irradiated mice against lenticular opacity. The experimental data indicate that "light" water strengthens the general body resistance as well as slows down aging of mammals.

  2. A role for γS-crystallin in the organization of actin and fiber cell maturation in the mouse lens

    PubMed Central

    Fan, Jianguo; Dong, Lijin; Mishra, Sanghamitra; Chen, Yingwei; FitzGerald, Paul; Wistow, Graeme

    2012-01-01

    γS-crystallin (γS) is a highly conserved component of the eye lens. To gain insights into the functional role(s) of this protein, the mouse gene (Crygs) was deleted. Although mutations in γS can cause severe cataracts, loss of function of γS in knockout (KO) mice produced no obvious lens opacity, but was associated with focusing defects. Electron microscopy showed no major differences in lens cell organization, suggesting that the optical defects are primarily cytoplasmic in origin. KO lenses were also grossly normal by light microscopy but showed evidence of incomplete clearance of cellular organelles in maturing fiber cells. Phalloidin labeling showed an unusual distribution of F-actin in a band of mature fiber cells in KO lenses, suggesting a defect in the organization or processing of the actin cytoskeleton. Indeed, in wild-type lenses, γS and F-actin colocalize along the fiber cell plasma membrane. Relative levels of F-actin and G-actin in wild-type and KO lenses were estimated from fluorescent staining profiles and from isolation of actin fractions from whole lenses. Both methods showed a twofold reduction in the F-actin/G-actin ratio in KO lenses, whereas no difference in tubulin organization was detected. In vitro experiments showed that recombinant mouse γS can directly stabilize F-actin. This suggests that γS may have a functional role related to actin, perhaps in ‘shepherding’ filaments to maintain the optical properties of the lens cytoplasm and normal fiber cell maturation. PMID:22715935

  3. Monochromatic, Rosseland mean, and Planck mean opacity routine

    NASA Astrophysics Data System (ADS)

    Semenov, D.

    2006-11-01

    Several FORTRAN77 codes were developed to compute frequency-dependent, Rosseland and Planck mean opacities of gas and dust in protoplanetary disks. The opacities can be computed for an ensemble of dust grains having various compositions (ices, silicates, organics, etc), sizes, topologies (homogeneous/composite aggregates, homogeneous/layered/composite spheres, etc.), porosities, and dust-to-gas ratio. Several examples are available. In addition, a very fast opacity routine to be used in modeling of the radiative transfer in hydro simulations of disks is available upon request (10^8 routine calls require about 30s on Pentium 4 3.0GHz).

  4. Experiment to measure oxygen opacity at high density and temperature

    NASA Astrophysics Data System (ADS)

    Keiter, Paul; Mussack, Katie; Orban, Chris; Colgan, James; Ducret, Jean-Eric; Fontes, Christopher J.; Guzik, Joyce Ann; Heeter, Robert F.; Kilcrease, Dave; Le Pennec, Maelle; Mancini, Roberto; Perry, Ted; Turck-Chièze, Sylvaine; Trantham, Matt

    2017-06-01

    In recent years, there has been a debate over the abundances of heavy elements (Z >2) in the solar interior. Recent solar atmosphere models [Asplund 2009] find a significantly lower abundance for C, N, and O compared to models used roughly a decade ago. This discrepancy has led to an investigation of opacities through laboratory experiments and improved opacity models for many of the larger contributors to the sun’s opacity, including iron and oxygen. Recent opacity measurements of iron disagree with opacity model predictions [Bailey et al, 2015]. Although these results are still controversial, repeated scrutiny of the experiment and data has not produced a conclusive reason for the discrepancy. New models have been implemented in the ATOMIC opacity code for C, O and Fe to address the solar abundance issue [Colgan, 2013]. Armstrong et al [2014] have also implemented changes in the ATOMIC code for low-Z elements. However, no data currently exists to test the low-Z material models in the regime relevant to the solar convection zone. We present an experimental design using the opacity platform developed at the National Ignition Facility to study the oxygen opacity at densities and temperatures near the solar convection zone conditions.This work is funded by the U.S. DOE, through the NNSA-DS and SC-OFES Joint Program in HEDPLP, grant No. DE-NA0001840, and the NLUF Program, grant No. DE-NA0000850, and through LLE, University of Rochester by the NNSA/OICF under Agreement No. DE-FC52-08NA28302.

  5. Treatment of atomic and molecular line blanketing by opacity sampling

    NASA Technical Reports Server (NTRS)

    Johnson, H. R.; Krupp, B. M.

    1976-01-01

    A sampling technique for treating the radiative opacity of large numbers of atomic and molecular lines in cool stellar atmospheres is subjected to several tests. In this opacity sampling (OS) technique, the global opacity is sampled at only a selected set of frequencies, and at each of these frequencies the total monochromatic opacity is obtained by summing the contribution of every relevant atomic and molecular line. In accord with previous results, we find that the structure of atmospheric models is accurately fixed by the use of 1000 frequency points, and 100 frequency points are adequate for many purposes. The effects of atomic and molecular lines are separately studied. A test model computed using the OS method agrees very well with a model having identical atmospheric parameters, but computed with the giant line (opacity distribution function) method.

  6. Galactic cold cores. V. Dust opacity

    NASA Astrophysics Data System (ADS)

    Juvela, M.; Ristorcelli, I.; Marshall, D. J.; Montillaud, J.; Pelkonen, V.-M.; Ysard, N.; McGehee, P.; Paladini, R.; Pagani, L.; Malinen, J.; Rivera-Ingraham, A.; Lefèvre, C.; Tóth, L. V.; Montier, L. A.; Bernard, J.-P.; Martin, P.

    2015-12-01

    Context. The project Galactic Cold Cores has carried out Herschel photometric observations of interstellar clouds where the Planck satellite survey has located cold and compact clumps. The sources represent different stages of cloud evolution from starless clumps to protostellar cores and are located in different Galactic environments. Aims: We examine this sample of 116 Herschel fields to estimate the submillimetre dust opacity and to search for variations that might be attributed to the evolutionary stage of the sources or to environmental factors, including the location within the Galaxy. Methods: The submillimetre dust opacity was derived from Herschel data, and near-infrared observations of the reddening of background stars are converted into near-infrared optical depth. We investigated the systematic errors affecting these parameters and used modelling to correct for the expected biases. The ratio of 250 μm and J band opacities is correlated with the Galactic location and the star formation activity. We searched for local variations in the ratio τ(250 μm)/τ(J) using the correlation plots and opacity ratio maps. Results: We find a median ratio of τ(250 μm) /τ(J) = (1.6 ± 0.2) × 10-3, which is more than three times the mean value reported for the diffuse medium. Assuming an opacity spectral index β = 1.8 instead of β = 2.0, the value would be lower by ~ 30%. No significant systematic variation is detected with Galactocentric distance or with Galactic height. Examination of the τ(250 μm) /τ(J) maps reveals six fields with clear indications of a local increase of submillimetre opacity of up to τ(250 μm) /τ(J) ~ 4 × 10-3 towards the densest clumps. These are all nearby fields with spatially resolved clumps of high column density. Conclusions: We interpret the increase in the far-infrared opacity as a sign of grain growth in the densest and coldest regions of interstellar clouds. Planck (http://www.esa.int/Planck) is a project of the European

  7. Accounting for Ethnicity-Related Differences in Ocular Surface Integrity as a Step Toward Understanding Contact Lens Discomfort.

    PubMed

    Chan, Stefanie M; Svitova, Tatyana F; Lin, Meng C

    2017-01-01

    Contact lens discomfort is a common problem that can lead to unsuccessful or limited contact lens wear. Although many factors may contribute to contact lens discomfort, limited research has explored the influence of ethnicity-related differences in the anatomy and physiology of the ocular surface. Therefore, we performed a search of the literature in PubMed using key words related to "ocular surface" paired with the terms "race" and "ethnicity." The goal of this review was to determine potential areas of research regarding ethnicity differences, particularly between Asian and non-Asian eyes, in ocular surface integrity to advance our understanding of contact lens discomfort.

  8. Unilateral congenital corneal keloid with anterior segment mesenchymal dysgenesis and subluxated lens: case report and review of literature.

    PubMed

    Vanathi, M; Sen, Seema; Panda, Anita; Dada, Tanuj; Behera, Geeta; Khokhar, Sudharshan

    2007-01-01

    To report the unusual association of unilateral congenital corneal keloid with anterior-segment mesenchymal dysgenesis and bilateral subluxated lens. A 20-year old man presented with a mass lesion involving the left cornea. The corneal lesion had been present since birth. On biomicroscopic examination, a well-defined vascularized, grayish-white mass occupying the whole of the left cornea was seen. The right eye showed multiple peripheral corneal opacities with iridocorneal adhesions, a poorly defined supranasal limbus, and a subluxated lens. Excision biopsy of the mass was done for histopathologic examination. Histopathologic examination of the excised corneal mass showed features consistent with that of a corneal keloid: thickened keratinized epithelium, absent Bowman membrane layer, and fibrovascular hyperplasia composed of hyalinized collagen fibers with irregular orientation of the collagen lamellae. During penetrating keratoplasty of the left eye, an anomalous iris pattern with poorly defined angle and a supranasal subluxated lens was also observed. Extraction of the subluxated lens was also done. The graft failed subsequent to a nonhealing persistent epithelial defect. Our case report highlights the rare association of a unilateral congenital corneal keloid with anterior-segment mesenchymal dysgenesis and bilateral subluxated lens.

  9. The role of Prdx6 in the protection of cells of the crystalline lens from oxidative stress induced by UV exposure.

    PubMed

    Shibata, Shinsuke; Shibata, Naoko; Shibata, Teppei; Sasaki, Hiroshi; Singh, Dhirendra P; Kubo, Eri

    2016-09-01

    The immediate aim of this study was to investigate alterations in peroxiredoxin (Prdx) 6 at posttranslational levels, and the levels of protein oxidation, lipid peroxidation, and reactive oxygen species (ROS) in lens epithelial cells (LECs) after exposure to severe oxidative stress, such as ultraviolet-B (UV-B). Our ultimate aim was to provide new information on antioxidant defenses in the lens and their regulation, thereby broadening existing knowledge of the role of Prdx6 in lens physiology and pathophysiology. The expression of the hyperoxidized form of Prdx6 and oxidation of protein were analyzed by western blotting and the OxyBlot assay in human LECs (hLECs). ROS levels were quantified using DCFH-DA dye, and cell viability was quantified by the MTS and TUNEL assays. To evaluate the protective effect of Prdx6, we cultured lenses with or without the TAT transduction domain (TAT-HA-Prdx6) and observed (and photographed) the cultures at specified time-points after the exposure to UV-B for the development of opacity. Prdx6 in hLECs was hyperoxidized after exposure to high amounts of UV-B. UV-B treatment of hLECs increased the levels of cell death, protein oxidation, and ROS. hLECs exposed to UV-B showed higher levels of ROS, which could be reduced by the application of extrinsic TAT-HA-Prdx6, attenuating UV-B-induced lens opacity and apoptotic cell death. Excessive oxidative stress induces the hyperoxidation of Prdx6 and may reduce the ability of Prdx6 to protect LECs against ROS or stresses. Because extrinsic Prdx6 could attenuate UV-B-induced abuse, this molecule may have a potential in preventing cataractogenesis.

  10. Crystalline lens thickness determines the perceived chromatic difference in magnification.

    PubMed

    Chen, Yun; Schaeffel, Frank

    2014-03-01

    Since the origin of the high interindividual variability of the chromatic difference in retinal image magnification (CDM) in the human eye is not well understood, optical parameters that might determine its magnitude were studied in 21 healthy subjects with ages ranging from 21 to 58 years. Two psychophysical procedures were used to quantify CDM. They produced highly correlated results. First, a red and a blue square, presented on a black screen, had to be matched in size by the subjects with their right eyes. Second, a filled red and blue square, flickering on top of each other at 2 Hz, had to be adjusted in perceived brightness and then in size to minimize the impression of flicker. CDM varied widely among subjects from 0.0% to 3.6%. Biometric ocular parameters were measured with low coherence interferometry and crystalline lens tilt and decentration with a custom-built Purkinjemeter. Correlations were studied between CDM and corneal power, anterior chamber depth, lens thickness, lens tilt and lens decentration, and vitreous chamber depths. Lens thickness was found significantly correlated with CDM and accounted for 64% of its variance. Vertical lens tilt and decentration were also significantly correlated. It was also found that CDM increased by 3.5% per year, and part of this change can be attributed to the age-related increase in lens thickness.

  11. The current status of eye lens dose measurement in interventional cardiology personnel in Thailand.

    PubMed

    Krisanachinda, Anchali; Srimahachota, Suphot; Matsubara, Kosuke

    2017-06-01

    Workers involved in interventional cardiology procedures receive high eye lens doses if radiation protection tools are not properly utilized. Currently, there is no suitable method for routine measurement of eye dose. In Thailand, the eye lens equivalent doses in terms of Hp(3) of the interventional cardiologists, nurses, and radiographers participating in interventional cardiology procedures have been measured at 12 centers since 2015 in the pilot study. The optically stimulated luminescence (OSL) dosimeter was used for measurement of the occupational exposure and the eye lens dose of 42 interventional cardiology personnel at King Chulalongkorn Memorial Hospital as one of the pilot centers. For all personnel, it is recommended that a first In Light OSL badge is placed at waist level and under the lead apron for determination of Hp(10); a second badge is placed at the collar for determination of Hp(0.07) and estimation of Hp(3). Nano Dots OSL dosimeter has been used as an eye lens dosimeter for 16 interventional cardiology personnel, both with and without lead-glass eyewear. The mean effective dose at the body, equivalent dose at the collar, and estimated eye lens dose were 0.801, 5.88, and 5.70 mSv per year, respectively. The mean eye lens dose measured by the Nano Dots dosimeter was 8.059 mSv per year on the left eye and 3.552 mSv per year on the right eye. Two of 16 interventional cardiologists received annual eye lens doses on the left side without lead glass that were higher than 20 mSv per year, the new eye lens dose limit as recommended by ICRP with the risk of eye lens opacity and cataract.

  12. Correlation of plume opacity with particles and sulfates from boilers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lou, J.C.; Lee, M.; Chen, K.S.

    1997-07-01

    The effects of emission concentrations of particulate matters and sulfates on plume opacity are investigated by in situ measurements. The studies are conducted for three processes of two coal-fired plants and one oil-fired that are all equipped with electrostatic precipitators. Flue-gas sampling and analysis include the concentrations of particles and total water soluble sulfates, particle size distribution, and flue-gas composition; while in-stack and out-of-stack opacities are determined by a transmissometer and certified smoke inspectors, respectively. Experimental results show that plume opacity outside the stack linearly correlates well with the in-stack opacity. The mixing of hot flue gas with cold ambientmore » air would result in the condensation of hygroscopic sulfuric acid aerosols and an increase about 1.6% out of typical 15--25% measured opacity. An empirical equation similar to the Beer-Lambert-Bouger form is derived for predicting the plume opacity in terms of the stack diameter and the concentrations of particles and total water soluble sulfates. Good comparisons are achieved between predictions by the empirical equation and other available field data.« less

  13. The Effect of the Crystalline Lens on Central Vault After Implantable Collamer Lens Implantation.

    PubMed

    Qi, Meng-Ying; Chen, Qian; Zeng, Qing-Yan

    2017-08-01

    To identify associations between crystalline lens-related factors and central vault after Implantable Collamer Lens (ICL) (Staar Surgical, Monrovia, CA) implantation. This retrospective clinical study included 320 eyes from 186 patients who underwent ICL implantation surgery. At 1 year after surgery, the central vault was measured using anterior segment optical coherence tomography. Preoperative anterior chamber depth, lens thickness, lens position (lens position = anterior chamber depth + 1/2 lens thickness), and vault were analyzed to investigate the effects of lens-related factors on postoperative vault. The mean vault was 513 ± 215 µm at 1 year after surgery. Vault was positively correlated with preoperative anterior chamber depth (r = 0.495, P < .001) and lens position (r = 0.371, P < .001), but negatively correlated with lens thickness (r = -0.262, P < .001). Eyes with vaults of less than 250 µm had shallower anterior chambers, thicker lenses, and smaller lens position than eyes in the other two vault groups (which had vaults ≥ 250 µm) (P < .001). Eyes with both anterior chamber depth less than 3.1 mm and lens position less than 5.1 mm had greatly reduced vaults (P < .001). The crystalline lens could have an important influence on postoperative vault. Eyes with a shallower anterior chamber and a forward lens position will have lower vaults. [J Refract Surg. 2017;33(8):519-523.]. Copyright 2017, SLACK Incorporated.

  14. Heterochromatic Flicker Photometry for Objective Lens Density Quantification.

    PubMed

    Najjar, Raymond P; Teikari, Petteri; Cornut, Pierre-Loïc; Knoblauch, Kenneth; Cooper, Howard M; Gronfier, Claude

    2016-03-01

    Although several methods have been proposed to evaluate lens transmittance, to date there is no consensual in vivo approach in clinical practice. The aim of this study was to compare ocular lens density and transmittance measurements obtained by an improved psychophysical scotopic heterochromatic flicker photometry (sHFP) technique to the results obtained by three other measures: a psychophysical threshold technique, a Scheimpflug imaging technique, and a clinical assessment using a validated subjective scale. Forty-three subjects (18 young, 9 middle aged, and 16 older) were included in the study. Individual lens densities were measured and transmittance curves were derived from sHFP indexes. Ocular lens densities were compared across methods by using linear regression analysis. The four approaches showed a quadratic increase in lens opacification with age. The sHFP technique revealed that transmittance decreased with age over the entire visual spectrum. This decrease was particularly pronounced between young and older participants in the short (53.03% decrease in the 400-500 nm range) wavelength regions of the light spectrum. Lens density derived from sHFP highly correlated with the values obtained with the other approaches. Compared to other objective measures, sHFP also showed the lowest variability and the best fit with a quadratic trend (r2 = 0.71) of lens density increase as a function of age. The sHFP technique offers a practical, reliable, and accurate method to measure lens density in vivo and predict lens transmittance over the visible spectrum. An accurate quantification of lens transmittance should be obtained in clinical practice, but also in research in visual and nonvisual photoreception.

  15. SOURCES OF BINOCULAR SUPRATHRESHOLD VISUAL FIELD LOSS IN A COHORT OF OLDER WOMEN BEING FOLLOWED FOR RISK OF FALLS (AN AMERICAN OPHTHALMOLOGICAL SOCIETY THESIS)

    PubMed Central

    Coleman, Anne Louise

    2007-01-01

    Purpose To determine the sources of binocular visual field loss most strongly associated with falls in a cohort of older women. Methods In the Study of Osteoporotic Fractures, women with severe binocular visual field loss had an increased risk of two or more falls during the 12 months following the eye examination. The lens and fundus photographs of the 422 women with severe binocular visual field loss, plus a random sample of 141 white women with no, mild, or moderate binocular visual field loss—47 white women with no binocular visual field loss, 46 white women with mild binocular visual field loss, and 48 white women with moderate binocular visual field loss —were evaluated for lens opacities, glaucomatous optic nerve damage, age-related macular degeneration, and diabetic retinopathy. Results Eighty-four percent of the women with severe binocular visual field loss had ocular disease in one or both eyes. Bilateral cataracts and glaucomatous optic nerve damage were the most common sources of this severe binocular visual field loss. Approximately 15.2% of women had no evidence of lens opacities, glaucomatous optic nerve damage, age-related macular degeneration, or diabetic retinopathy. Conclusion Severe binocular visual field loss due primarily to cataracts, glaucoma, and age-related macular degeneration explains 33.3% of the falls among women who fell frequently. Because binocular visual field loss may be treatable and/or preventable, screening programs for binocular visual field loss and subsequent referral for intervention and treatment are recommended as a strategy for preventing falls among the elderly. PMID:18427619

  16. Research on Spectroscopy, Opacity, and Atmospheres

    NASA Technical Reports Server (NTRS)

    Kurucz, Robert L.

    1999-01-01

    To make my calculations more readily accessible I have set up a web site cfaku5.harvard.edu that can also be accessed by FTP. it has 5 9GB disks that hold all of my atomic and diatomic molecular data, my tables of distribution function opacities, my grids of model atmospheres, colors, fluxes, etc, my program that are ready for distribution, most of my recent papers. Atlases and computed spectra will be added as they are completed. New atomic and molecular calculations will be added as they are completed. I got my atomic programs that had been running on a Cray at the San Diego Supercomputer Center to run on my Vaxes and Alpha. I started with Ni and Co because there were new laboratory analyses that included isotopic and hyperfine splitting. Those calculations are described in the appended abstract for the 6th Atomic Spectroscopy and oscillator Strengths meeting in Victoria last summer. A surprising finding is that quadrupole transitions have been grossly in error because mixing with higher levels has not been included. I now have enough memory in my Alpha to treat 3000 x 3000 matrices. I now include all levels up through n=9 for Fe I and 11, the spectra for which the most information is available. I am finishing those calculations right now. After Fe I and Fe 11, all other spectra are "easy", and I will be in mass production. ATL;LS12, my opacity sampling program for computing models with arbitrary abundances, has been put on the web server. I wrote a new distribution function opacity program for workstations that replaces the one I used on the Cray at the San Diego Supercomputer Center. Each set of abundances would take 100 Cray hours costing $100,000. 1 ran 25 cases. Each of my opacity CDs contains three abundances. I have a new program -iinning on the Alpha that takes about a week. I am going to have to get a faster processor or I will have to dedicate a whole workstation just to opacities.

  17. Hyperelastic modelling of the crystalline lens: Accommodation and presbyopia

    PubMed Central

    Lanchares, Elena; Navarro, Rafael; Calvo, Begoña

    2012-01-01

    Purpose The modification of the mechanical properties of the human crystalline lens with age can be a major cause of presbyopia. Since these properties cannot be measured in vivo, numerical simulation can be used to estimate them. We propose an inverse method to determine age-dependent change in the material properties of the tissues composing the human crystalline lens. Methods A finite element model of a 30-year-old lens in the accommodated state was developed. The force necessary to achieve full accommodation in a 30-year-old lens of known external geometry was computed using this model. Two additional numerical models of the lens corresponding to the ages of 40 and 50 years were then built. Assuming that the accommodative force applied to the lens remains constant with age, the material properties of nucleus and cortex were estimated by inverse analysis. Results The zonular force necessary to reshape the model of a 30-year-old lens from the accommodated to the unaccommodated geometry was 0.078 newton (N). Both nucleus and cortex became stiffer with age. The stiffness of the nucleus increased with age at a higher rate than the cortex. Conclusions In agreement with the classical theory of Helmholtz, on which we based our model, our results indicate that a major cause of presbyopia is that both nucleus and cortex become stiffer with age; therefore, a constant value of the zonular forces with aging does not achieve full accommodation, that is, the accommodation capability decreases.

  18. On the methane opacity for Uranus and Neptune.

    NASA Technical Reports Server (NTRS)

    Trafton, L.

    1972-01-01

    The contribution of methane to the thermal opacity in the atmospheres of Uranus and Neptune is shown to be negligible. The relevance of this finding lies in the importance of knowing all the sources of thermal opacity to include in models of these atmospheres, for only then may it be possible to deduce their atmospheric structure and composition correctly.

  19. Universe opacity and CMB

    NASA Astrophysics Data System (ADS)

    Vavryčuk, Václav

    2018-07-01

    A cosmological model, in which the cosmic microwave background (CMB) is a thermal radiation of intergalactic dust instead of a relic radiation of the big bang, is revived and revisited. The model suggests that a virtually transparent local Universe becomes considerably opaque at redshifts z > 2-3. Such opacity is hardly to be detected in the Type Ia supernova data, but confirmed using quasar data. The opacity steeply increases with redshift because of a high proper density of intergalactic dust in the previous epochs. The temperature of intergalactic dust increases as (1 + z) and exactly compensates the change of wavelengths due to redshift, so that the dust radiation looks apparently like the radiation of the blackbody with a single temperature. The predicted dust temperature is TD = 2.776 K, which differs from the CMB temperature by 1.9 per cent only, and the predicted ratio between the total CMB and extragalactic background light (EBL) intensities is 13.4 which is close to 12.5 obtained from observations. The CMB temperature fluctuations are caused by EBL fluctuations produced by galaxy clusters and voids in the Universe. The polarization anomalies of the CMB correlated with temperature anisotropies are caused by the polarized thermal emission of needle-shaped conducting dust grains aligned by large-scale magnetic fields around clusters and voids. A strong decline of the luminosity density for z > 4 is interpreted as the result of high opacity of the Universe rather than of a decline of the global stellar mass density at high redshifts.

  20. Universe opacity and CMB

    NASA Astrophysics Data System (ADS)

    Vavryčuk, Václav

    2018-04-01

    A cosmological model, in which the cosmic microwave background (CMB) is a thermal radiation of intergalactic dust instead of a relic radiation of the Big Bang, is revived and revisited. The model suggests that a virtually transparent local Universe becomes considerably opaque at redshifts z > 2 - 3. Such opacity is hardly to be detected in the Type Ia supernova data, but confirmed using quasar data. The opacity steeply increases with redshift because of a high proper density of intergalactic dust in the previous epochs. The temperature of intergalactic dust increases as (1 + z) and exactly compensates the change of wavelengths due to redshift, so that the dust radiation looks apparently like the radiation of the blackbody with a single temperature. The predicted dust temperature is TD = 2.776 K, which differs from the CMB temperature by 1.9% only, and the predicted ratio between the total CMB and EBL intensities is 13.4 which is close to 12.5 obtained from observations. The CMB temperature fluctuations are caused by EBL fluctuations produced by galaxy clusters and voids in the Universe. The polarization anomalies of the CMB correlated with temperature anisotropies are caused by the polarized thermal emission of needle-shaped conducting dust grains aligned by large-scale magnetic fields around clusters and voids. A strong decline of the luminosity density for z > 4 is interpreted as the result of high opacity of the Universe rather than of a decline of the global stellar mass density at high redshifts.

  1. Computational design of short pulse laser driven iron opacity experiments

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Martin, M. E.; London, R. A.; Goluoglu, S.

    Here, the resolution of current disagreements between solar parameters calculated from models and observations would benefit from the experimental validation of theoretical opacity models. Iron's complex ionic structure and large contribution to the opacity in the radiative zone of the sun make iron a good candidate for validation. Short pulse lasers can be used to heat buried layer targets to plasma conditions comparable to the radiative zone of the sun, and the frequency dependent opacity can be inferred from the target's measured x-ray emission. Target and laser parameters must be optimized to reach specific plasma conditions and meet x-ray emissionmore » requirements. The HYDRA radiation hydrodynamics code is used to investigate the effects of modifying laser irradiance and target dimensions on the plasma conditions, x-ray emission, and inferred opacity of iron and iron-magnesium buried layer targets. It was determined that plasma conditions are dominantly controlled by the laser energy and the tamper thickness. The accuracy of the inferred opacity is sensitive to tamper emission and optical depth effects. Experiments at conditions relevant to the radiative zone of the sun would investigate the validity of opacity theories important to resolving disagreements between solar parameters calculated from models and observations.« less

  2. Computational design of short pulse laser driven iron opacity experiments

    DOE PAGES

    Martin, M. E.; London, R. A.; Goluoglu, S.; ...

    2017-02-23

    Here, the resolution of current disagreements between solar parameters calculated from models and observations would benefit from the experimental validation of theoretical opacity models. Iron's complex ionic structure and large contribution to the opacity in the radiative zone of the sun make iron a good candidate for validation. Short pulse lasers can be used to heat buried layer targets to plasma conditions comparable to the radiative zone of the sun, and the frequency dependent opacity can be inferred from the target's measured x-ray emission. Target and laser parameters must be optimized to reach specific plasma conditions and meet x-ray emissionmore » requirements. The HYDRA radiation hydrodynamics code is used to investigate the effects of modifying laser irradiance and target dimensions on the plasma conditions, x-ray emission, and inferred opacity of iron and iron-magnesium buried layer targets. It was determined that plasma conditions are dominantly controlled by the laser energy and the tamper thickness. The accuracy of the inferred opacity is sensitive to tamper emission and optical depth effects. Experiments at conditions relevant to the radiative zone of the sun would investigate the validity of opacity theories important to resolving disagreements between solar parameters calculated from models and observations.« less

  3. Severe keratomalacia after 12 months of continuous hydrogel contact lens wear in a psychiatric patient.

    PubMed

    Rico-Sergado, Laura; Pérez-Canales, Jose L; Pérez-Santonja, Juan J; Cigüenza-Sancho, Sonia

    2015-04-01

    A 53-year-old cachectic patient diagnosed with major depressive disorder was referred to our department for evaluation of a visible deformation of the right eye. She had been wearing hydrogel contact lenses on a continuous basis without removal for the last 12 months, influenced by low self-esteem and social isolation. Slit-lamp examination of the right eye showed a conical cornea, extensive neovascularization, severe stromal melting with descemetocele formation and forward bulging of the iris. Examination of the left eye revealed multiple corneal opacities, deep stromal neovascularization and anterior chamber inflammation. No sign of infection was present. Vitamin A deficiency was suspected and later confirmed. The patient required evisceration of the right eye and psychiatric treatment. Inflammatory signs of the left eye resolved within 1 week of initiating treatment. This case illustrates the synergistic effect of soft contact lens abuse and vitamin A deficiency in a psychiatric patient, and emphasizes the importance of instructing vulnerable patients on appropriate lens use and care. Copyright © 2014 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  4. Dependent lung opacity at thin-section CT: evaluation by spirometrically-gated CT of the influence of lung volume.

    PubMed

    Lee, Ki Nam; Yoon, Seong Kuk; Sohn, Choon Hee; Choi, Pil Jo; Webb, W Richard

    2002-01-01

    To evaluate the influence of lung volume on dependent lung opacity seen at thin-section CT. In thirteen healthy volunteers, thin-section CT scans were performed at three levels (upper, mid, and lower portion of the lung) and at different lung volumes (10, 30, 50, and 100% vital capacity), using spirometric gated CT. Using a three-point scale, two radiologists determined whether dependent opacity was present, and estimated its degree. Regional lung attenuation at a level 2 cm above the diaphragm was determined using semiautomatic segmentation, and the diameter of a branch of the right lower posterior basal segmental artery was measured at each different vital capacity. At all three anatomic levels, dependent opacity occurred significantly more often at lower vital capacities (10, 30%) than at 100% vital capacity (p = 0.001). Visually estimated dependent opacity was significantly related to regional lung attenuation (p < 0.0001), which in dependent areas progressively increased as vital capacity decreased (p < 0.0001). The presence of dependent opacity and regional lung attenuation of a dependent area correlated significantly with increased diameter of a segmental arterial branch (r = 0.493 and p = 0.0002; r = 0.486 and p = 0.0003, respectively). Visual estimation and CT measurements of dependent opacity obtained by semiautomatic segmentation are significantly influenced by lung volume and are related to vascular diameter.

  5. Dietary vitamin C and E modulates oxidative stress induced-kidney and lens injury in diabetic aged male rats through modulating glucose homeostasis and antioxidant systems.

    PubMed

    Özkaya, Dilek; Naziroğlu, Mustafa; Armağan, Abdullah; Demirel, Alpay; Köroglu, Banu Kale; Çolakoğlu, Neriman; Kükner, Aysel; Sönmez, Tolga Taha

    2011-06-01

    Diabetes induces oxidative stress in aged human and rat, although daily supplementation of vitamins C and E (VCE) can be beneficial to aged diabetic rats by reducing free radical production. The aim of the present study was to evaluate whether dietary VCE supplementation relieves oxidative stress in streptozotocin (STZ)-induced diabetic in aged rats. Thirty aged rats were randomly divided into three groups. The first group was used as a control. The second group was made diabetic using a single dose of intraperitoneal STZ. VCE-supplemented feed was given to aged diabetic rats constituting the third group. On the 21st day of the experiment, blood, lens and kidney samples were taken from all animals. Glutathione peroxidase (GSH-Px) activity in lens and kidney, reduced glutathione (GSH), vitamin E and β-carotene concentrations in kidney were lower in the diabetic group than in the control whereas plasma glucose, urea and creatinine, and kidney and lens peroxidation (LP) levels were higher in the diabetic group than in the control. However, kidney and lens LP levels, and plasma glucose, urea and creatinine values were decreased by VCE supplementation. Lens and kidney GSH-Px activity, kidney GSH, vitamin E and β-carotene concentrations and erythrocyte counts were increased by VCE treatment. Kidney weights, vitamin A, haemoglobin, hematocrit, leukocyte and platelets values were not changed by diabetes and/or VCE supplementation. VCE ameliorated also diabetes-induced histopathological changes in kidney. In conclusion, we observed that VCE supplementation is beneficial towards kidney and lens of aged diabetic rats by modulating oxidative and antioxidant systems. Copyright © 2011 John Wiley & Sons, Ltd.

  6. The role of configuration interaction in the LTE opacity of Fe

    NASA Astrophysics Data System (ADS)

    Colgan, James; Kilcrease, David; Magee, Norm; Armstrong, Gregory; Abdallah, Joe; Sherrill, Manolo; Fontes, Christopher; Zhang, Honglin; Hakel, Peter

    2013-05-01

    The Los Alamos National Laboratory code ATOMIC has been recently used to generate a series of local-thermodynamic-equilibrium (LTE) light element opacities for the elements H through Ne. Our calculations, which include fine-structure detail, represent a systematic improvement over previous Los Alamos opacity calculations using the LEDCOP legacy code. Recent efforts have resulted in comprehensive new calculations of the opacity of Fe. In this presentation we explore the role of configuration interaction (CI) in the Fe opacity, and show where CI influences the monochromatic opacity. We present such comparisons for conditions of astrophysical interest. The Los Alamos National Laboratory is operated by Los Alamos National Security, LLC for the National Nuclear Security Administration of the U.S. Department of Energy under Contract No. DE-AC5206NA25396.

  7. Validation of the digital opacity compliance system under regulatory enforcement conditions.

    PubMed

    McFarland, Michael J; Rasmussen, Steve L; Stone, Daniel A; Palmer, Glenn R; Wander, Joseph D

    2006-09-01

    U.S. Environmental Protection Agency (EPA) Emission Measurement Center in conjunction with EPA Regions VI and VIII, the state of Utah, and the U.S. Department of Defense have conducted a series of long-term pilot and field tests to determine the accuracy and reliability of a visible opacity monitoring system consisting of a conventional digital camera and a separate computer software application for plume opacity determination. This technology, known as the Digital Opacity Compliance System (DOCS), has been successfully demonstrated at EPA-sponsored Method-9 "smoke schools", as well as at a number of government and commercially operated industrial facilities. Results from the current DOCS regulatory pilot study demonstrated that, under regulatory enforcement conditions, the average difference in opacity measurement between the DOCS technology and EPA Reference Method 9 (Method 9) was 1.12%. This opacity difference, which was computed from the evaluation of 241 regulated air sources, was found to be statistically significant at the 99% confidence level. In evaluating only those sources for which a nonzero visible opacity level was recorded, the

  8. Absorbance and light scattering of lenses organ cultured with glucose.

    PubMed

    Alghamdi, Ali Hendi Sahmi; Mohamed, Hasabelrasoul; Sledge, Samiyyah M; Borchman, Douglas

    2018-06-06

    Purpose/Aim: Diabetes is one of the major factors related to cataract. Our aim was to determine if the attenuation of light through glucose treated lenses was due to light scattering from structural changes or absorbance from metabolic changes. Human and rat lenses were cultured in a medium with and without 55 mM glucose for a period of five days. Absorbance and light scattering were measured using a ultraviolet spectrometer. Aldose reductase and catalase activity, RAGE, and glutathione were measured using classical assays. Almost all of the glucose related attenuation of light through the human lens was due to light scattering from structural changes. Glucose treatment caused three absorbance band to appear at 484, 540 to 644 and 657 nm in both the rat and human lens. The optimum time point for equilibration of human lenses was found to be between 2 and 3 days in organ culture. Glucose caused a more significant effect on the opacity of human lenses compared with rat lenses. Since the levels of glutathione, catalase and aldose reductase were reduced in glucose treated rat lenses compared with untreated lenses, glucose may have caused oxidative stress on the rat lens. The absorbance and light scattering of glucose treated lenses in organ culture were quantitated for the first time which could be important for future studies designed to test the efficacy of agents to ameliorate the opacity. Almost all of the glucose related attenuation of light through the human lens was due to light scattering from structural changes and not absorbance from metabolic changes. Glucose caused a more significant effect on the opacity of human lenses compared with rat lenses. The lens model employed could be used to study the efficacy of agents that potentially ameliorate lens opacity.

  9. Iron and molecular opacities and the evolution of Population I stars

    NASA Technical Reports Server (NTRS)

    Stothers, Richard B.; Chin, Chao-Wen

    1993-01-01

    Effects of recent opacity revisions on the evolution of Population I stars are explored over the range 1.5-60 solar masses. Opacity parameters considered include the angular momentum coupling scheme for iron, the relative iron abundance, the total metal abundance, and diatomic and triatomic molecular sources. Only the total metal abundance exerts an important control over the evolutionary tracks. Blue loops on the H-R diagram during core helium burning can be very sensitive to opacity, but only insofar as the simple formation or suppression of a blue loop is concerned. The blue loops are most robust for stellar masses around 10 solar masses. We confirm, from a comparison of stellar models with observational data, that the total metal abundance is close to solar and that convective core overshooting is likely to be very slight. The new models predict the existence of an iron convection zone in the envelope and a great widening of the main-sequence band in the H-R diagram at luminosities brighter than 100,000 solar luminosities.

  10. Supernova Neutrino Opacity from Nucleon-Nucleon Bremsstrahlung and Related Processes

    NASA Astrophysics Data System (ADS)

    Hannestad, Steen; Raffelt, Georg

    1998-11-01

    Elastic scattering on nucleons, νN --> Nν, is the dominant supernova (SN) opacity source for μ and τ neutrinos. The dominant energy- and number-changing processes were thought to be νe- --> e-ν and νν¯<-->e+e- until Suzuki showed that the bremsstrahlung process νν¯NN<-->NN was actually more important. We find that for energy exchange, the related ``inelastic scattering process'' νNN<-->NNν is even more effective by about a factor of 10. A simple estimate implies that the νμ and ντ spectra emitted during the Kelvin-Helmholtz cooling phase are much closer to that of ν¯e than had been thought previously. To facilitate a numerical study of the spectra formation we derive a scattering kernel that governs both bremsstrahlung and inelastic scattering and give an analytic approximation formula. We consider only neutron-neutron interactions; we use a one-pion exchange potential in Born approximation, nonrelativistic neutrons, and the long-wavelength limit, simplifications that appear justified for the surface layers of an SN core. We include the pion mass in the potential, and we allow for an arbitrary degree of neutron degeneracy. Our treatment does not include the neutron-proton process and does not include nucleon-nucleon correlations. Our perturbative approach applies only to the SN surface layers, i.e., to densities below about 1014 g cm-3.

  11. Improvement of chronic corneal opacity in ocular surface disease with prosthetic replacement of the ocular surface ecosystem (PROSE) treatment.

    PubMed

    Cressey, Anna; Jacobs, Deborah S; Remington, Crystal; Carrasquillo, Karen G

    2018-06-01

    To demonstrate clearing of chronic corneal opacities and improvement of visual acuity with the use of BostonSight prosthetic replacement of the ocular surface ecosystem (PROSE) treatment in ocular surface disease. We undertook retrospective analysis of the medical records of a series of patients who underwent PROSE treatment from August 2006 to December 2014. Patients were referred for ocular surface disease of various etiologies. Primary inclusion criterion was corneal opacity that improved with PROSE treatment. Patients were excluded if topical steroids or adjuvant therapy used once PROSE treatment was initiated. Underlying disease, prior treatment, clinical presentation, and clinical course were extracted from the medical record. Four patients are included in this series. There were three females and one male; median age at time of treatment initiation was 30 years (range = 0.5-58 years). Median duration of PROSE treatment at time of retrospective analysis was 3.5 years (range = 1-8 years). Two cases had corneal opacification in the context of neurotrophic keratopathy: a unilateral case due to presumed herpes simplex keratitis and a bilateral case due to congenital corneal anesthesia associated with familial dysautonomia. One case had corneal opacity from exposure related to seventh nerve palsy, and one had corneal opacification associated with recurrent surface breakdown, neurotrophic keratopathy, and limbal stem deficiency of uncertain etiology. After consistent wear of prosthetic devices used in PROSE treatment for support of the ocular surface, visual acuity improved and clearing of the opacities was observed, without use of topical steroids or adjuvant therapy. These cases demonstrate clearing of chronic corneal opacity with PROSE treatment for ocular surface disease. This clearing can occur with no adjuvant therapy, suggesting that restoration of ocular surface function and integrity allows for corneal remodeling.

  12. Cataract formation associated with ocular toxocariasis.

    PubMed

    Ahn, Seong Joon; Woo, Se Joon; Hyon, Joon Young; Park, Kyu Hyung

    2013-06-01

    To report the clinical features of cataracts in eyes with ocular toxocariasis. Department of Ophthalmology, Seoul National University Bundang Hosptal, Seongnam, South Korea. Retrospective observational case series. The clinical diagnosis of ocular toxocariasis was based on the following characteristic features: retinal granuloma with or without ocular inflammation and positive results in serum antibody enzyme-linked immunosorbent assay. Patients younger than 60 years who presented with a unilateral cataract and were diagnosed with ocular toxocariasis between January 2009 and January 2012 were included. Demographic and ocular examination data for all patients showing atypical cataract features were collected. All cataracts were documented with anterior segment photography. Seven of 83 patients (8.4%) presented with an atypical cataract in the eye with ocular toxocariasis only. The mean patient age was 49.7 years ± 8.3 (SD) (range 38 to 59 years). All patients had small, round, white lens opacities resembling retinal granulomas. The granuloma-like opacities were located primarily in the lens midperiphery and in the subcapsular level. The lens opacity migrated in 1 patient. Ocular toxocariasis can cause a cataract with distinctive clinical features. These cataracts show a granuloma-like opacity primarily in the posterior subcapsular level; the opacity can migrate. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2013 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  13. Risk factors for interruption to soft contact lens wear in children and young adults.

    PubMed

    Wagner, Heidi; Chalmers, Robin L; Mitchell, G Lynn; Jansen, Meredith E; Kinoshita, Beth T; Lam, Dawn Y; McMahon, Timothy T; Richdale, Kathryn; Sorbara, Luigina

    2011-08-01

    The purpose of this study was to describe age and other risk factors for ocular events that interrupt soft contact lens (SCL) wear in youth. A retrospective chart review of SCL wearers aged 8 to 33 years at the first observed visit was conducted at six academic eye care centers in North America. Data were extracted from all visits during the observation period (>3 years). Clinical records that documented conditions resulting in an interruption of SCL wear "events" were scanned, masked for age and SCL parameters, and then adjudicated to consensus diagnosis. Generalized estimating equations were used to examine the effect of selected covariates, including age, on the risk of an event. Chart review of 3549 SCL wearers yielded 522 events among 426 wearers (12%). The risk of an event increased from ages 8 to 18 years, showed modest increases between ages 19 and 25 years, and then began to decline after age 25 years. New lens wearers (<1 year) were less likely to experience events (p = 0.001). Lens replacement schedule and material were also predictive of interruptions to SCL wear with the lowest risk in daily replacement and hydrogel lens wearers (both p < 0.0001). These results suggest that the risk of events that interrupt SCL wear peaks in late adolescence and early adulthood and reflects risk factors identified in prospective contact lens studies. Relative to older teens and young adults, patients younger than 14 years presented with significantly fewer events resulting in interrupted lens wear.

  14. Lens growth and protein changes in the eastern grey kangaroo

    PubMed Central

    2011-01-01

    Purpose Development in marsupials takes place predominantly ex utero while the young is attached to a nipple in the mother’s pouch, very different from that in other species. This study was undertaken to examine whether this affects lens growth and the production of lens proteins in kangaroos. Methods Fresh lenses were obtained at official culls from eastern gray kangaroos (Macropus giganteus). Wet weights were recorded for all and protein contents were determined for one lens from each animal. Dry weights, after fixation were obtained for 20 lenses. Ages were determined using both molar progression and total lens protein content. Lenses were divided into concentric layers by controlled dissolution using phosphate buffered saline. Samples were taken for determination of protein contents and dry weights, which were then used to determine the age of the layer removed. Soluble crystallin distributions were determined by fractionation of the centrifuged extracts using HPLC-GPC and the polypeptide contents of both soluble and insoluble proteins were assessed by SDS–PAGE. Results Lens growth is continuous from birth throughout adulthood and the increases in wet weight and fixed dry weight can be described with a single logistic growth functions for the whole life span. Three major crystallin classes, α-, β-, and γ-crystallins, were identified in the immature pouch-young animals aged around 60 days after birth. Adult lenses contain, in addition, the taxon-specific μ-crystallin. The proportions of these vary with the age of the lens tissue due to age related insolubilization as well as changes in the synthesis patterns. During early lactation (birth to 190 days), the α-, β-, and γ-crystallins represent 25, 53, and 20% of the total protein, respectively. After the pouch-young first releases the nipple (190 days), there is a rapid decrease in the production of γ-crystallins to around 5% of the total and a corresponding increase in μ-crystallin, from 0.5% to 15

  15. Lens growth and protein changes in the eastern grey kangaroo.

    PubMed

    Augusteyn, Robert C

    2011-01-01

    Development in marsupials takes place predominantly ex utero while the young is attached to a nipple in the mother's pouch, very different from that in other species. This study was undertaken to examine whether this affects lens growth and the production of lens proteins in kangaroos. Fresh lenses were obtained at official culls from eastern gray kangaroos (Macropus giganteus). Wet weights were recorded for all and protein contents were determined for one lens from each animal. Dry weights, after fixation were obtained for 20 lenses. Ages were determined using both molar progression and total lens protein content. Lenses were divided into concentric layers by controlled dissolution using phosphate buffered saline. Samples were taken for determination of protein contents and dry weights, which were then used to determine the age of the layer removed. Soluble crystallin distributions were determined by fractionation of the centrifuged extracts using HPLC-GPC and the polypeptide contents of both soluble and insoluble proteins were assessed by SDS-PAGE. Lens growth is continuous from birth throughout adulthood and the increases in wet weight and fixed dry weight can be described with a single logistic growth functions for the whole life span. Three major crystallin classes, α-, β-, and γ-crystallins, were identified in the immature pouch-young animals aged around 60 days after birth. Adult lenses contain, in addition, the taxon-specific μ-crystallin. The proportions of these vary with the age of the lens tissue due to age related insolubilization as well as changes in the synthesis patterns. During early lactation (birth to 190 days), the α-, β-, and γ-crystallins represent 25, 53, and 20% of the total protein, respectively. After the pouch-young first releases the nipple (190 days), there is a rapid decrease in the production of γ-crystallins to around 5% of the total and a corresponding increase in μ-crystallin, from 0.5% to 15%. These changes were complete

  16. OPACITY BROADENING OF {sup 13}CO LINEWIDTHS AND ITS EFFECT ON THE VARIANCE-SONIC MACH NUMBER RELATION

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Correia, C.; De Medeiros, J. R.; Burkhart, B.

    2014-04-10

    We study how the estimation of the sonic Mach number (M{sub s} ) from {sup 13}CO linewidths relates to the actual three-dimensional sonic Mach number. For this purpose we analyze MHD simulations that include post-processing to take radiative transfer effects into account. As expected, we find very good agreement between the linewidth estimated sonic Mach number and the actual sonic Mach number of the simulations for optically thin tracers. However, we find that opacity broadening causes M{sub s} to be overestimated by a factor of ≈1.16-1.3 when calculated from optically thick {sup 13}CO lines. We also find that there ismore » a dependence on the magnetic field: super-Alfvénic turbulence shows increased line broadening compared with sub-Alfvénic turbulence for all values of optical depth for supersonic turbulence. Our results have implications for the observationally derived sonic Mach number-density standard deviation (σ{sub ρ/(ρ)}) relationship, σ{sub ρ/〈ρ〉}{sup 2}=b{sup 2}M{sub s}{sup 2}, and the related column density standard deviation (σ {sub N/(N)}) sonic Mach number relationship. In particular, we find that the parameter b, as an indicator of solenoidal versus compressive driving, will be underestimated as a result of opacity broadening. We compare the σ {sub N/(N)}-M{sub s} relation derived from synthetic dust extinction maps and {sup 13}CO linewidths with recent observational studies and find that solenoidally driven MHD turbulence simulations have values of σ {sub N/(N)}which are lower than real molecular clouds. This may be due to the influence of self-gravity which should be included in simulations of molecular cloud dynamics.« less

  17. A higher-than-predicted measurement of iron opacity at solar interior temperatures.

    PubMed

    Bailey, J E; Nagayama, T; Loisel, G P; Rochau, G A; Blancard, C; Colgan, J; Cosse, Ph; Faussurier, G; Fontes, C J; Gilleron, F; Golovkin, I; Hansen, S B; Iglesias, C A; Kilcrease, D P; MacFarlane, J J; Mancini, R C; Nahar, S N; Orban, C; Pain, J-C; Pradhan, A K; Sherrill, M; Wilson, B G

    2015-01-01

    Nearly a century ago it was recognized that radiation absorption by stellar matter controls the internal temperature profiles within stars. Laboratory opacity measurements, however, have never been performed at stellar interior conditions, introducing uncertainties in stellar models. A particular problem arose when refined photosphere spectral analysis led to reductions of 30-50 per cent in the inferred amounts of carbon, nitrogen and oxygen in the Sun. Standard solar models using the revised element abundances disagree with helioseismic observations that determine the internal solar structure using acoustic oscillations. This could be resolved if the true mean opacity for the solar interior matter were roughly 15 per cent higher than predicted, because increased opacity compensates for the decreased element abundances. Iron accounts for a quarter of the total opacity at the solar radiation/convection zone boundary. Here we report measurements of wavelength-resolved iron opacity at electron temperatures of 1.9-2.3 million kelvin and electron densities of (0.7-4.0) × 10(22) per cubic centimetre, conditions very similar to those in the solar region that affects the discrepancy the most: the radiation/convection zone boundary. The measured wavelength-dependent opacity is 30-400 per cent higher than predicted. This represents roughly half the change in the mean opacity needed to resolve the solar discrepancy, even though iron is only one of many elements that contribute to opacity.

  18. Application of adipose-derived stem cells on scleral contact lens carrier in an animal model of severe acute alkaline burn.

    PubMed

    Espandar, Ladan; Caldwell, Delmar; Watson, Richard; Blanco-Mezquita, Tomas; Zhang, Shijia; Bunnell, Bruce

    2014-07-01

    To evaluate the therapeutic effect of human adipose-derived stem cells (hASCs) overlaid on a scleral contact lens (SCL) carrier in a rabbit model of ocular alkaline burn. After inducing alkaline burn in 11 New Zealand white rabbits, hASCs cultured on SCLs were placed on the right eye of 5 rabbits, SCLs without cells were used in 5, and no treatment was applied in 1 eye. Each eye was examined and photographed for corneal vascularization, opacities, and epithelial defect in week 1, 2, and 4 after surgery. After 1 month, rabbits were killed and the corneas were removed and cut in half for electron and light microscopy examination. Human adipose-derived stem cells were attached to SCL surface and confluent easily. Human adipose-derived stem cells on SCL eyes showed smaller epithelial defect, less corneal opacity, corneal neovascularization relative to SCL eyes. Both groups showed no symblepharon. However, the cornea in the untreated eye was melted in 2 weeks and developed severe symblepharon. Human adipose-derived stem cells on SCL can reduce inflammation and corneal haziness in severe ocular alkaline burn injury in rabbits.

  19. Application of Adipose-Derived Stem Cells on Scleral Contact Lens Carrier in an Animal Model of Severe Acute Alkaline Burn

    PubMed Central

    Espandar, Ladan; Caldwell, Delmar; Watson, Richard; Blanco-Mezquita, Tomas; Zhang, Shijia; Bunnell, Bruce

    2015-01-01

    Purpose To evaluate the therapeutic effect of human adipose-derived stem cells (hASCs) overlaid on a scleral contact lens (SCL) carrier in a rabbit model of ocular alkaline burn. Materials and Methods After inducing alkaline burn in 11 New Zealand white rabbits, hASCs cultured on SCLs were placed on the right eye of 5 rabbits, SCLs without cells were used in 5, and no treatment was applied in 1 eye. Each eye was examined and photographed for corneal vascularization, opacities, and epithelial defect in week 1, 2, and 4 after surgery. After 1 month, rabbits were killed and the corneas were removed and cut in half for electron and light microscopy examination. Results Human adipose-derived stem cells were attached to SCL surface and confluent easily. Human adipose-derived stem cells on SCL eyes showed smaller epithelial defect, less corneal opacity, corneal neovascularization relative to SCL eyes. Both groups showed no symblepharon. However, the cornea in the untreated eye was melted in 2 weeks and developed severe symblepharon. Conclusion Human adipose-derived stem cells on SCL can reduce inflammation and corneal haziness in severe ocular alkaline burn injury in rabbits. PMID:24901976

  20. The hydrogeology of complex lens conditions in Qatar

    NASA Astrophysics Data System (ADS)

    Lloyd, J. W.; Pike, J. G.; Eccleston, B. L.; Chidley, T. R. E.

    1987-01-01

    The emirate of Qatar lies on a peninsula extending northward from the mainland of Saudi Arabia into the Arabian Gulf. The peninsula is underlain by sedimentary rocks ranging from late Cretaceous to Holocene age but only two Lower Tertiary units are identified as aquifers. The groundwater distribution in these units is seen to be controlled by facies distributions related to tectonically controlled sedimentation and subsequent dissolution. Dissolution has created permeability, in the Umm er Rhaduma limestones and in the overlying Rus anhydrites. In the latter case the dissolution has lead to extensive surface collapse which has provided a mechanism for recharge from runoff. Despite very low rainfall and high evaporation rates, recharge related to storm runoff has resulted in the establishment of a complex fresh groundwater lens in both aquifer units. The lens is constrained by saline groundwaters which in the lower unit are controlled by heads in eastern Saudi Arabia but in the upper unit by the Arabian Gulf sea level. Groundwater abstraction is shown to be distorting the fresh groundwater lens configuration, and estimates of the resultant flow responses affecting the lens are given.

  1. OPAC Missing Record Retrieval.

    ERIC Educational Resources Information Center

    Johnson, Karl E.

    1996-01-01

    When the Higher Education Library Information Network of Rhode Island transferred members' bibliographic data into a shared online public access catalog (OPAC), 10% of the University of Rhode Island's monograph records were missing. This article describes the consortium's attempts to retrieve records from the database and the effectiveness of…

  2. Refractive power and biometric properties of the nonhuman primate isolated crystalline lens.

    PubMed

    Borja, David; Manns, Fabrice; Ho, Arthur; Ziebarth, Noel M; Acosta, Ana Carolina; Arrieta-Quintera, Esdras; Augusteyn, Robert C; Parel, Jean-Marie

    2010-04-01

    Purpose. To characterize the age dependence of shape, refractive power, and refractive index of isolated lenses from nonhuman primates. Methods. Measurements were performed on ex vivo lenses from cynomolgus monkeys (cyno: n = 120; age, 2.7-14.3 years), rhesus monkeys (n = 61; age, 0.7-13.3 years), and hamadryas baboons (baboon: n = 16; age, 1.7-27.3 years). Lens thickness, diameter, and surface curvatures were measured with an optical comparator. Lens refractive power was measured with a custom optical system based on the Scheiner principle. The refractive contributions of the gradient, the surfaces, and the equivalent refractive index were calculated with optical ray-tracing software. The age dependence of the optical and biometric parameters was assessed. Results. Over the measured age range isolated lens thickness decreased (baboon: -0.04, cyno: -0.05, and rhesus: -0.06 mm/y) and equatorial diameter increased (logarithmically for the baboon and rhesus, and linearly for cyno: 0.07 mm/y). The isolated lens surfaces flattened and the corresponding refractive power from the surfaces decreased with age (-0.33, -0.48, and -0.68 D/y). The isolated lens equivalent refractive index decreased (only significant for the baboon, -0.001 D/y), and as a result the total isolated lens refractive power decreased with age (baboon: -1.26, cyno: -0.97, and rhesus: -1.76 D/y). Conclusions. The age-dependent trends in the optical and biometric properties, growth, and aging, of nonhuman primate lenses are similar to those of the pre-presbyopic human lens. As the lens ages, the decrease in refractive contributions from the gradient refractive index causes a rapid age-dependent decrease in maximally accommodated lens refractive power.

  3. Patient Compliance During Contact Lens Wear: Perceptions, Awareness, and Behavior

    PubMed Central

    Bui, Thai H.; Cavanagh, H. Dwight; Robertson, Danielle M.

    2011-01-01

    Objectives Patient noncompliance with recommended hygienic practices in contact lens wear is often considered a significant risk factor for microbial keratitis and adverse contact lens–related events. Despite advancements in lens materials and care solutions, noncompliant behavior continues to hinder efforts to maximize contact lens safety. The objective of this pilot study was to assess the relationship between perceived and actual compliance with awareness of risk and behavior. Methods One hundred sixty-two established contact lens wearers were sequentially evaluated after their routine contact lens examination at the Optometry Clinic at the University of Texas Southwestern Medical Center at Dallas, TX. Each patient was questioned by a single trained interviewer regarding his or her lens care practices and knowledge of risk factors associated with lens wear. Results Eighty-six percent of patients believed they were compliant with lens wear and care practices; 14% identified themselves as noncompliant. Using a scoring model, 32% demonstrated good compliance, 44% exhibited average compliance, and 24% were noncompliant; age was a significant factor (P = 0.020). Only 34% of patients who perceived themselves as compliant exhibited a good level of compliance (P<0.001). Eighty percent of patients reported an awareness of risk factors, but awareness did not influence negative behavior. Replacing the lens case was the only behavior associated with a positive history for having experienced a prior contact lens–related complication (P = 0.002). Conclusions Perceived compliance is not an indicator for appropriate patient behavior. A large proportion of patients remain noncompliant despite awareness of risk. Education alone is not a sufficient strategy to improve behavior; newer approaches aimed at improving compliance with lens care practices are urgently needed. PMID:20935569

  4. UV-blocking spectacle lens protects against UV-induced decline of visual performance.

    PubMed

    Liou, Jyh-Cheng; Teng, Mei-Ching; Tsai, Yun-Shan; Lin, En-Chieh; Chen, Bo-Yie

    2015-01-01

    Excessive exposure to sunlight may be a risk factor for ocular diseases and reduced visual performance. This study was designed to examine the ability of an ultraviolet (UV)-blocking spectacle lens to prevent visual acuity decline and ocular surface disorders in a mouse model of UVB-induced photokeratitis. Mice were divided into 4 groups (10 mice per group): (1) a blank control group (no exposure to UV radiation), (2) a UVB/no lens group (mice exposed to UVB rays, but without lens protection), (3) a UVB/UV400 group (mice exposed to UVB rays and protected using the CR-39™ spectacle lens [UV400 coating]), and (4) a UVB/photochromic group (mice exposed to UVB rays and protected using the CR-39™ spectacle lens [photochromic coating]). We investigated UVB-induced changes in visual acuity and in corneal smoothness, opacity, and lissamine green staining. We also evaluated the correlation between visual acuity decline and changes to the corneal surface parameters. Tissue sections were prepared and stained immunohistochemically to evaluate the structural integrity of the cornea and conjunctiva. In blank controls, the cornea remained undamaged, whereas in UVB-exposed mice, the corneal surface was disrupted; this disruption significantly correlated with a concomitant decline in visual acuity. Both the UVB/UV400 and UVB/photochromic groups had sharper visual acuity and a healthier corneal surface than the UVB/no lens group. Eyes in both protected groups also showed better corneal and conjunctival structural integrity than unprotected eyes. Furthermore, there were fewer apoptotic cells and less polymorphonuclear leukocyte infiltration in corneas protected by the spectacle lenses. The model established herein reliably determines the protective effect of UV-blocking ophthalmic biomaterials, because the in vivo protection against UV-induced ocular damage and visual acuity decline was easily defined.

  5. An Evaluation of Online Help for the NOTIS OPAC.

    ERIC Educational Resources Information Center

    White, Frank

    1994-01-01

    Discussion of online help systems in online public access catalogs (OPACs) focuses on a study that evaluated the online help system for the NOTIS (Northwestern Online Total Integrated System) OPAC. Features of the system reviewed include online functions; training features; general interface features; access points; and message content and display…

  6. Design of Initial Opacity Platform at the National Ignition Facility

    NASA Astrophysics Data System (ADS)

    Heeter, R. F.; Ahmed, M. F.; Ayers, S. L.; Emig, J. A.; Iglesias, C. A.; Liedahl, D. A.; Schneider, M. B.; Wilson, B. G.; Huffman, E. J.; King, J. A.; Opachich, Y. P.; Ross, P. W.; Bailey, J. E.; Rochau, G. A.; Craxton, R. S.; Garcia, E. M.; McKenty, P. W.; Zhang, R.; Cardenas, T.; Devolder, B. G.; Dodd, E. S.; Kline, J. L.; Sherrill, M. E.; Perry, T. S.

    2016-10-01

    The absorption and re-emission of x-rays by partly stripped ions plays a critical role in stars and in many laboratory plasmas. A NIF Opacity Platform has been designed to resolve a persistent disagreement between theory and experiments on the Sandia Z facility, studying iron in conditions closely related to the solar radiation-convection transition boundary. A laser heated hohlraum ``oven'' will produce iron plasmas at temperatures >150 eV and electron densities >=7x1021/cm3, and be probed with continuum X-rays from a capsule implosion backlighter source. The resulting X-ray transmission spectra will be recorded on a specially designed Opacity Spectrometer. This work was performed under the auspices of the U.S. Department of Energy by LLNL under Contract DE-AC52-07NA27344.

  7. Research on the relation between the contact angle and the interface curvature radius of electrowetting liquid zoom lens

    NASA Astrophysics Data System (ADS)

    Zhao, Cunhua; Liang, Huiqin; Cui, Dongqing; Hong, Xinhua; Wei, Daling; Gao, Changliu

    2011-08-01

    In the ultralight or ultrathin applied domain of zoom lens, the traditional glass / plastic lens is limited for manufacture technology or cost. Therefore, a liquid lens was put forward to solve the problems. The liquid zoom lens has the merits of lower cost, smaller volume, quicker response, lower energy consumption, continuous zoom and higher accuracy. In liquid zoom lens the precise focal length is obtained by the contact angle changing to affect the curvature radius of interface. In our works, the relations of the exerted voltage, the contact angle, the curvature radius and the focal length were researched and accurately calculated. The calculation of the focal length provides an important theoretical basis for instructing the design of liquid zoom lens.

  8. Transient Asymptomatic Pulmonary Opacities Occurring during Osimertinib Treatment.

    PubMed

    Noonan, Sinead A; Sachs, Peter B; Camidge, D Ross

    2016-12-01

    Osimertinib is an EGFR inhibitor licensed for the treatment of EGFR-mutant, T790M-positive NSCLC. Previously unreported, frequent transient asymptomatic pulmonary opacities were noted in patients during osimertinib therapy at the University of Colorado. Computed tomography imaging and clinical notes on patients with NSCLC who had been treated with osimertinib at the University of Colorado were retrospectively reviewed. Transient asymptomatic pulmonary opacities developed in seven of 20 patients (35%) while they were receiving osimertinib. The radiological patterns seen included ground-glass opacities with or without nodular consolidation. The median time to development of the first lesion was 8.7 weeks (range 1.6-43 weeks), the median time to resolution during continued osimertinib was 6 weeks (range 1-11 weeks). Transient asymptomatic pulmonary opacities may be a previously unrecognized, benign feature associated with osimertinib therapy that may be mistaken for isolated pulmonary progression or the beginning of more severe pneumonitis. If new-onset pulmonary lesions, especially those associated with ground-glass appearances, are asymptomatic and localized and there is no evidence of disease progression elsewhere, it may be reasonable to continue treatment with osimertinib and monitor the lesions for resolution. Copyright © 2016 International Association for the Study of Lung Cancer. Published by Elsevier Inc. All rights reserved.

  9. Association Between Contact Lens Discomfort and Pre-lens Tear Film Kinetics.

    PubMed

    Guillon, Michel; Dumbleton, Kathryn A; Theodoratos, Panagiotis; Wong, Stephanie; Patel, Kishan; Banks, Gaidig; Patel, Trisha

    2016-08-01

    The relationship between contact lens wettability and comfort has been extensively evaluated; however, a direct correlation between the characteristics of the pre-lens tear film and the symptoms associated with contact lens discomfort has yet to be established. In addition, there is relatively limited knowledge relating to the entire tear film kinetics during the inter-blink period in contact lens wearers. The purpose of this analysis was to identify the characteristics of the pre-lens tear film kinetics that may be associated with the symptoms of contact lens discomfort. The study population comprised 202 soft (hydrogel and silicone hydrogel) contact lens wearers attending pre-screening visits at the OTG-i research clinic. All participants completed the Ocular Surface Disease Index (OSDI) questionnaire and the tear film was quantified via post hoc, masked analysis of high definition digital Tearscope videos recorded at the visit. The tear film kinetics of the least symptomatic wearers (OSDI lowest quintile scores, n = 45) were compared to the tear film kinetics of the most symptomatic wearers (OSDI highest quintile scores, n = 43). The hypothesis tested was that the tear film kinetics of asymptomatic wearers were better than tear film kinetics of symptomatic wearers. The distribution of lens types worn was as follows: Daily Disposable 46.5%, 1-Month Replacement 39.6%, and 2-Week Replacement 13.6%. 48.2% of lenses were silicone hydrogel and 51.8% hydrogel. Symptomatic wearers had a shorter break-up time (4.7 s vs. 6.0 s; p = 0.003), lesser surface coverage by the tear film during the interblink period (95.1% vs. 98.5%; p < 0.001) and greater surface exposure at the time of the blink (9.4% vs. 3.9%; p = 0.001). The current study demonstrated that the tear film kinetics of asymptomatic and symptomatic contact lens wearers were different, the findings supporting the hypothesis of poorer tear film kinetics for symptomatic than asymptomatic wearers in a general contact

  10. Identification of preoperative prediction factors of tumor subtypes for patients with solitary ground-glass opacity pulmonary nodules.

    PubMed

    Li, Meishuang; Wang, Yanan; Chen, Yulong; Zhang, Zhenfa

    2018-01-17

    Recent wide spread use of low-dose helical computed tomography for the screening of lung cancer have led to an increase in the detection rate of very faint and smaller lesions known as ground-glass opacity nodules. The purpose of this study was to investigate the clinical factors of lung cancer patients with solitary ground-glass opacity pulmonary nodules on computed tomography. A total of 423 resected solitary ground-glass opacity nodules were retrospectively evaluated. We analyzed the clinical, imaging and pathological data and investigated the clinical differences in patient with adenocarcinoma in situ / minimally invasive adenocarcinoma and those with invasive adenocarcinoma. Three hundred and ninety-three adenocarcinomas (92.9%) and 30 benign nodules were diagnosed. Age, the history of family cancer, serum carcinoembryonic antigen level, tumor size, ground-glass opacity types, and bubble-like sign in chest CT differed significantly between adenocarcinoma in situ / minimally invasive adenocarcinoma and invasive adenocarcinoma (p:0.008, 0.046, 0.000, 0.000, 0.000 and 0.001). Receiver operating characteristic curves and univariate analysis revealed that patients with more than 58.5 years, a serum carcinoembryonic antigen level > 1.970 μg/L, a tumor size> 13.50 mm, mixed ground-glass opacity nodules and a bubble-like sign were more likely to be diagnosed as invasive adenocarcinoma. The combination of five factors above had an area under the curve of 0.91, with a sensitivity of 82% and a specificity of 87%. The five-factor combination helps us to distinguish adenocarcinoma in situ / minimally invasive adenocarcinoma from invasive adenocarcinoma and to perform appropriate surgery for solitory ground-glass opacity nodules.

  11. Diagnosis of high-temperature implosions using low- and high-opacity Krypton lines

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yaakobi, B.; Epstein, R.; Hooper, C.F. Jr.

    1996-04-01

    High-temperature laser target implosions can be achieved by using relatively thin-shell targets, and they can be. diagnosed by doping the fuel with krypton and measuring K-shell and L-shell lines. Electron temperatures of up to 5 keV at modest compressed densities ({approximately}1-5g/cm{sup 3}) are predicted for such experiments, with ion temperatures peaking above 10 keV at the center. It is found that the profiles of low-opacity (optically thin) lines in the expected density range are dominated by the Doppler broadening and can provide a measurement of the ion temperature if spectrometers of spectral resolution {Delta}{lambda}/{lambda} {ge} 1000 are used. For high-opacitymore » lines, obtained with a higher krypton fill pressure, the measurement of the escape factor can yield the {rho}R of the compressed fuel. At higher densities, Stark broadening of low-opacity lines becomes important and can provide a density measurement, whereas lines of higher opacity can be used to estimate the extent of mixing.« less

  12. Lens capsule structure assessed with atomic force microscopy

    PubMed Central

    Sueiras, Vivian M.; Moy, Vincent T.

    2015-01-01

    Purpose To image the ultrastructure of the anterior lens capsule at the nanoscale level using atomic force microscopy (AFM). Methods Experiments were performed on anterior lens capsules maintained in their in situ location surrounding the lens from six human cadavers (donor age range: 44–88 years), four cynomolgus monkeys (Macaca fascicularis age range: 4.83–8.92 years), and seven pigs (<6 months). Hydration of all samples was maintained using Dulbecco’s Modified Eagle Medium (DMEM). Whole lenses were removed from the eye and placed anterior side up in agarose gel before gel hardening where only the posterior half of the lens was contained within the gel. After the gel hardened, the Petri dish was filled with DMEM until the point where the intact lens was fully submerged. AFM was used to image the anterior lens surface in contact mode. An integrated analysis program was used to calculate the interfibrillar spacing, fiber diameter, and surface roughness of the samples. Results The AFM images depict a highly ordered fibrous structure at the surface of the lens capsule in all three species. The interfibrillar spacing for the porcine, cynomolgus monkey, and human lens capsules was 0.68±0.25, 1.80±0.39, and 1.08±0.25 μm, respectively. In the primate, interfibrillar spacing significantly decreased linearly as a function of age. The fiber diameters ranged from 50 to 950 nm. Comparison of the root mean square (RMS) and average deviation demonstrate that the surface of the porcine lens capsule is the smoothest, and that the human and cynomolgus monkey capsules are significantly rougher. Conclusions AFM was successful in providing high-resolution images of the nanostructure of the lens capsule samples. Species-dependent differences were observed in the overall structure and surface roughness. PMID:25814829

  13. Intraocular Lenses for the Treatment of Age-Related Cataracts

    PubMed Central

    2009-01-01

    Executive Summary Objective The objective of the report is to examine the comparative effectiveness and cost-effectiveness of various intraocular lenses (IOLs) for the treatment of age-related cataracts. Clinical Need: Target Population and Condition A cataract is a hardening and clouding of the normally transparent crystalline lens that may result in a progressive loss of vision depending on its size, location and density. The condition is typically bilateral, seriously compromises visual acuity and contrast sensitivity and increases glare. Cataracts can also affect people at any age, however, they usually occur as a part of the natural aging process. The occurrence of cataracts increases with age from about 12% at age 50 years, to 60% at age 70. In general, approximately 50% of people 65 year of age or older have cataracts. Mild cataracts can be treated with a change in prescription glasses, while more serious symptoms are treated by surgical removal of the cataract and implantation of an IOL. In Ontario, the estimated prevalence of cataracts increased from 697,000 in 1992 to 947,000 in 2004 (35.9% increase, 2.4% annual increase). The number of cataract surgeries per 1,000 individuals at risk of cataract increased from 64.6 in 1992 to 140.4 in 1997 (61.9% increase, 10.1% annual increase) and continued to steadily increase to 115.7 in 2004 (10.7% increase, 5.2% increase per year). Description of Technology/Therapy IOLs are classified either as monofocal, multifocal, or accommodative. Traditionally, monofocal (i.e.. fixed focusing power) IOLs are available as replacement lenses but their implantation can cause a loss of the eye’s accommodative capability (which allows variable focusing). Patients thus usually require eyeglasses after surgery for reading and near vision tasks. Multifocal IOLs aim to improve near and distant vision and obviate the need for glasses. Potential disadvantages include reduced contrast sensitivity, halos around lights and glare

  14. Effects of Nongray Opacity on Radiatively Driven Wolf-Rayet Winds

    NASA Astrophysics Data System (ADS)

    Onifer, A. J.; Gayley, K. G.

    2002-05-01

    Wolf-Rayet winds are characterized by their large momentum fluxes, and simulations of radiation driving have been increasingly successful in modeling these winds. Simple analytic approaches that help understand the most critical processes for copious momentum deposition already exist in the effectively gray approximation, but these have not been extended to more realistic nongray opacities. With this in mind, we have developed a simplified theory for describing the interaction of the stellar flux with nongray wind opacity. We replace the detailed line list with a set of statistical parameters that are sensitive not only to the strength but also the wavelength distribution of lines, incorporating as a free parameter the rate of photon frequency redistribution. We label the resulting flux-weighted opacity the statistical Sobolev- Rosseland (SSR) mean, and explore how changing these various statistical parameters affects the flux/opacity interaction. We wish to acknowledge NSF grant AST-0098155

  15. Glutathione and catalase suppress TGFβ-induced cataract-related changes in cultured rat lenses and lens epithelial explants

    PubMed Central

    Chamberlain, Coral G.; Cerra, Anna

    2009-01-01

    Purpose The damaging effects of oxidative stress and transforming growth factor-β (TGFβ)-induced transdifferentiation of lens epithelial cells have both been implicated independently in the etiology of cataract. The aim of this study was to investigate whether the presence of antioxidant systems in the lens influences the ability of lens epithelial cells to respond to TGFβ. Methods Whole lenses from young rats were cultured with or without TGFβ in the presence or absence of reduced glutathione (GSH). Lens epithelial explants from weanling rats were used to investigate the effects of GSH and catalase on TGFβ-induced cataract-related changes. Lenses were monitored for opacification for three to four days, photographed, and then processed for routine histology. Explants were assessed by phase contrast microscopy, enzyme-linked immunosorbent assay (ELISA) of α-smooth muscle actin (αSMA), and/or immunolocalization of αSMA and Pax6, markers for transdifferentiation and normal lens epithelial phenotype, respectively. Results In cultured lenses, GSH strongly suppressed TGFβ-induced opacification and subcapsular plaque formation. In explants, both GSH and catalase suppressed changes typically associated with TGFβ-induced transdifferentiation including wrinkling of the lens capsule, cell-surface blebbing, apoptotic cell loss, induction of αSMA, and loss of Pax6 expression. Conclusions This study suggests that antioxidant systems present in the normal lens, which protect the epithelium against the damaging effects of reactive oxygen species, may also serve to protect it against the potentially cataractogenic effects of TGFβ. Taken together with other recent studies, it also raises the possibility that TGFβ may induce cataract-related changes in lens epithelial cells via release of hydrogen peroxide. PMID:19421408

  16. VizieR Online Data Catalog: Opacities from the Opacity Project (Seaton+, 1995)

    NASA Astrophysics Data System (ADS)

    Seaton, M. J.; Yan, Y.; Mihalas, D.; Pradhan, A. K.

    1997-08-01

    1 CODES. ***** 1.1 Code rop.for ************ This code reads opacity files written in standard OP format. Its main purpose is to provide documentation on the contents of the files. This code, like the other codes provided, prompts for the name of the file (or files) to be read. The file names read in response to the prompt may have up to 128 characters. 1.2 Code opfit.for ************** This code reads opacity files in standard OP format, and provides for interpolation of opacities to any required values of temperature and mass-density. The method used is described in OPF. The code prompts for the name of a file giving all required control parameters. As an example, the file opfit.dat is provided (users will need to change directory names and file names). The use of opfit.for is illustrated using opfit.dat. Most users will probably want to adapt opfit.for for use as a subroutine in other codes. Timings for DEC 7000 ALPHA: 0.3 sec for data read and initialisations; then 0.0007 sec for each temperature-density point. Users who like OPAL formats should note that opfit.for has a facility to produce files of OP data in OPAL-type formats. 1.3 Code ixz.for ************ This code provides for interpolations to any required values of X and Z. See IXZ. It prompts for the name of a file giving all required control parameters. An example of such a file if provided, ixz.dat (the user will need to change directory and file names). The output files have names s92INT.'nnn'. The user specifies the first value of nnn, and the number of files to be produced. 2. DATA FILES ********** 2.1 Data files for solar metal-mix ****************************** Data for solar metal-mix s92 as defined in SYMP. These files are from version 2 runs of December 1994 (see IXZ for details on Version 2). There are 213 files with names s92.'nnn', 'nnn'=201 to 413. Each file occupies 83762 bytes. The file s92.version2 gives values of X (hydrogen mass-faction) and Z (metals mass-fraction) for each value of

  17. Atomic structure considerations for the low-temperature opacity of Sn

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Colgan, J.; Kilcrease, D. P.; Abdallah, J.

    Here, we have begun a preliminary investigation into the opacity of Sn at low temperatures (< 50 eV). The emissivity and opacity of Sn is a crucial factor in determining the utility of Sn in EUV lithography, with numerous industrial implications. To this end, we have been exploring the accuracy of some approximations used in opacity models for the relevant ion stages of Sn (neutral through ~ 18 times ionized). We also find that the use of intermediate-coupling, as compared to full configuration-interaction, is not adequate to obtain accurate line positions of the important bound-bound transitions in Sn. One requiresmore » full configuration-interaction to properly describe the strong mixing between the various n=4 sub-shells that give rise to the Δn= 0 transitions that dominate the opacity spectrum at low temperatures. Furthermore, since calculations that include full configuration-interaction for large numbers of configurations quickly become computationally prohibitive, we have explored hybrid calculations, in which full configuration-interaction is retained for the most important transitions, while intermediate-coupling is employed for all other transitions. After extensive exploration of the atomic structure properties, local-thermodynamic-equilibrium (LTE) opacities are generated using the ATOMIC code at selected temperatures and densities and compared to experiment.« less

  18. Atomic structure considerations for the low-temperature opacity of Sn

    DOE PAGES

    Colgan, J.; Kilcrease, D. P.; Abdallah, J.; ...

    2017-03-31

    Here, we have begun a preliminary investigation into the opacity of Sn at low temperatures (< 50 eV). The emissivity and opacity of Sn is a crucial factor in determining the utility of Sn in EUV lithography, with numerous industrial implications. To this end, we have been exploring the accuracy of some approximations used in opacity models for the relevant ion stages of Sn (neutral through ~ 18 times ionized). We also find that the use of intermediate-coupling, as compared to full configuration-interaction, is not adequate to obtain accurate line positions of the important bound-bound transitions in Sn. One requiresmore » full configuration-interaction to properly describe the strong mixing between the various n=4 sub-shells that give rise to the Δn= 0 transitions that dominate the opacity spectrum at low temperatures. Furthermore, since calculations that include full configuration-interaction for large numbers of configurations quickly become computationally prohibitive, we have explored hybrid calculations, in which full configuration-interaction is retained for the most important transitions, while intermediate-coupling is employed for all other transitions. After extensive exploration of the atomic structure properties, local-thermodynamic-equilibrium (LTE) opacities are generated using the ATOMIC code at selected temperatures and densities and compared to experiment.« less

  19. [The occupational radiation-induced cataract in five industrial radiographers].

    PubMed

    Benzarti Mezni, A; Loukil, I; Hriz, N; Kallel, K; Mlaiki, N; Ben Jemaâ, A

    2012-04-01

    The industrial uses of ionizing radiation in Tunisia are expanding, especially in industry and most particularly in the nondestructive testing of welds. Thus workers operating in the non-destructive testing of welds may develop a radiation-induced cataract varying in time to onset depending on the dose. To describe the characteristics of the radiation-induced cataract in patients exposed to ionizing radiation, determine the risk factors of radiation-induced cataracts. This was an anamnestic, clinical, and environmental study of five cases of radiation-induced cataract in workers employed in non-destructive testing of welds. This series of five cases had a mean age of 30.2 years and 5.53 years of work experience, ranging from 14 months to 15 years. All the patients were male and industrial radiographers specialized in nondestructive testing of welds. The average duration of exposure to ionizing radiation was 5.53 years. None of the patients had worn protective gear such as eye goggles. The ophthalmic check-up for the five special industrial radiographers showed punctuate opacities in three cases, punctiform opacities in one eye in one case, and phacosclerosis with bilateral lens multiple crystalline stromal opacities in a case of micro-lens opacities in both eyes with opalescence of both eyes in one case. These cataracts had been declared as occupational diseases. The value of a specialized ophthalmologic surveillance among these workers and the early diagnosis of lens opacities must be emphasized. Copyright © 2011 Elsevier Masson SAS. All rights reserved.

  20. 40 CFR 63.1653 - Opacity standards.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 60 percent opacity, measured as a 6-minute average. (b) Blowing taps, poling and oxygen lancing of the tap hole; burndowns associated with electrode measurements; and maintenance activities associated...

  1. Contact lens material characteristics associated with hydrogel lens dehydration.

    PubMed

    Ramamoorthy, Padmapriya; Sinnott, Loraine T; Nichols, Jason J

    2010-03-01

    To determine the association between material dehydration and hydrogel contact lens material characteristics, including water content and ionicity. Water content and refractive index data were derived from automated refractometry measurements of worn hydrogel contact lenses of 318 participants in the Contact Lens and Dry Eye Study (CLADES). Dehydration was determined in two ways; as the difference between nominal and measured (1) water content and (2) refractive index. Multiple regression models were used to examine the relation between dehydration and material characteristics, controlling for tear osmolality. The overall measured and nominal water content values were 52.58 +/- 7.49% and 56.88 +/- 7.81% respectively, while the measured and nominal refractive indices were 1.429 +/- 0.015 and 1.410 +/- 0.017. High water content and ionic hydrogel lens materials were associated with greater dehydration (p < 0.0001 for both) than low water content and non-ionic materials. When dehydration was assessed as the difference in refractive index, only high water content was associated with dehydration (p < 0.0001). High water content and ionic characteristics of hydrogel lens materials are associated with hydrogel lens dehydration, with the former being more strongly associated. Such dehydration changes could in turn lead to important clinical ramifications such as reduced oxygen transmissibility, greater lens adherence and reduced tear exchange.

  2. Age-related changes in the kinetics of human lenses: prevention of the cataract

    PubMed Central

    Pescosolido, Nicola; Barbato, Andrea; Giannotti, Rossella; Komaiha, Chiara; Lenarduzzi, Fiammetta

    2016-01-01

    The crystalline lens is a transparent, biconvex structure in the eye that, along with the cornea, helps to refract light to be focused on the retina and, by changing shape, it adjusts focal distance (accommodation). The three classes of structural proteins found in the lens are α, β, and γ crystallins. These proteins make up more than 90% of the total dry mass of the eye lens. Other components which can be found are sugars, lipids, water, several antioxidants and low weight molecules. When ageing changes occur in the lens, it causes a gradual reduction in transparency, presbyopia and an increase in the scattering and aberration of light waves as well as a degradation of the optical quality of the eye. The main changes that occur with aging are: 1) reduced diffusion of water from the outside to the inside of the lens and from its cortical to its nuclear zone; 2) crystalline change due to the accumulation of high molecular weight aggregates and insoluble proteins; 3) production of advanced glycation end products (AGEs), lipid accumulation, reduction of reduced glutathione content and destruction of ascorbic acid. Even if effective strategies in preventing cataract onset are not already known, good results have been reached in some cases with oral administration of antioxidant substances such as caffeine, pyruvic acid, epigallocatechin gallate (EGCG), α-lipoic acid and ascorbic acid. Furthermore, methionine sulfoxide reductase A (MSRA) over expression could protect lens cells both in presence and in absence of oxidative stress-induced damage. Nevertheless, promising results have been obtained by reducing ultraviolet-induced oxidative damage. PMID:27803872

  3. Opacity Limit for Supermassive Protostars

    NASA Astrophysics Data System (ADS)

    Becerra, Fernando; Marinacci, Federico; Inayoshi, Kohei; Bromm, Volker; Hernquist, Lars E.

    2018-04-01

    We present a model for the evolution of supermassive protostars from their formation at {M}\\star ≃ 0.1 {M}ȯ until their growth to {M}\\star ≃ {10}5 {M}ȯ . To calculate the initial properties of the object in the optically thick regime, we follow two approaches: one based on idealized thermodynamic considerations, and another based on a more detailed one-zone model. Both methods derive a similar value of {n}{{F}}≃ 2× {10}17 {cm}}-3 for the density of the object when opacity becomes important, i.e., the opacity limit. The subsequent evolution of the growing protostar is determined by the accretion of gas onto the object and can be described by a mass–radius relation of the form {R}\\star \\propto {M}\\star 1/3 during the early stages, and of the form {R}\\star \\propto {M}\\star 1/2 when internal luminosity becomes important. For the case of a supermassive protostar, this implies that the radius of the star grows from {R}\\star ≃ 0.65 {au} to {R}\\star ≃ 250 {au} during its evolution. Finally, we use this model to construct a subgrid recipe for accreting sink particles in numerical simulations. A prime ingredient thereof is a physically motivated prescription for the accretion radius and the effective temperature of the growing protostar embedded inside it. From the latter, we can conclude that photoionization feedback can be neglected until very late in the assembly process of the supermassive object.

  4. Vitrectomy for primary symptomatic vitreous opacities: an evidence-based review

    PubMed Central

    Ivanova, T; Jalil, A; Antoniou, Y; Bishop, P N; Vallejo-Garcia, J L; Patton, N

    2016-01-01

    Floaters are a common ocular condition which form as a consequence of aging changes in the vitreous. Although in most patients the symptoms are minimal, they can cause significant impairment in vision-related quality of life in a small population of patients. Recently there has been an increase in awareness of the visual disability caused by floaters, and the evidence-base for treatment of this condition using small-gauge vitrectomy has increased. In this review, we define the term ‘floaters' as symptomatic vitreous opacities (SVO). We suggest a classification dependent on the presence or absence of posterior vitreous detachment and discuss their pathogenesis and natural history. We review their impact on patients' quality of life related to visual function. We review the psychological factors that may have a role in some patients who appear to be affected by SVO to the extent that they pursue all options including surgery with all its attendant risks. We summarise the available evidence-base of treatment options available for SVO with special emphasis on the safety and efficacy of vitrectomy for this condition. PMID:26939559

  5. Fly ash system technology improves opacity

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    2007-06-15

    Unit 3 of the Dave Johnston Power Plant east of Glenrock, WY, USA had problems staying at or below the opacity limits set by the state. The unit makes use of a Lodge Cottrell precipitator. When the plant changed to burning Power River Basin coal, ash buildup became a significant issue as the fly ash control system was unable to properly evacuate hoppers on the unit. To overcome the problem, the PLC on the unit was replaced with a software optimization package called SmartAsh for the precipitator fly ash control system, at a cost of $500,000. After the upgrade, theremore » have been no plugged hoppers and the opacity has been reduced from around 20% to 3-5%. 2 figs.« less

  6. [Keratoconus special soft contact lens fitting].

    PubMed

    Yamazaki, Ester Sakae; da Silva, Vanessa Cristina Batista; Morimitsu, Vagner; Sobrinho, Marcelo; Fukushima, Nelson; Lipener, César

    2006-01-01

    To evaluate the fitting and use of a soft contact lens in keratoconic patients. Retrospective study on 80 eyes of 66 patients, fitted with a special soft contact lens for keratoconus, at the Contact Lens Section of UNIFESP and private clinics. Keratoconus was classified according to degrees of disease severity by keratometric pattern. Age, gender, diagnosis, keratometry, visual acuity, spherical equivalent (SE), base curve and clinical indication were recorded. Of 66 patients (80 eyes) with keratoconus the mean age was 29 years, 51.5% were men and 48.5% women. According to the groups: 15.0% were incipient, 53.7% moderate, 26.3% advanced and 5.0% were severe. The majority of the eyes of patients using contact lenses (91.25%) achieved visual acuity better than 20/40. To 88 eyes 58% were tihed with lens with spherical power (mean -5.45 diopters) and 41% with spherocylinder power (from -0.5 to -5.00 cylindrical diopters). The most frequent base curve was 7.6 in 61% of the eyes. The main reasons for this special lens fitting were due to reduced tolerance and poor fitting pattern achieved with other lenses. The special soft contact lens is useful in fitting difficult keratoconic patients by offering comfort and improving visual rehabilitation that may allow more patients to postpone the need for corneal transplant.

  7. OPACs in the Clouds

    ERIC Educational Resources Information Center

    Webb, Paula L.; Nero, Muriel D.

    2009-01-01

    In today's world of instant everything, everyone has been exposed to some form of Web 2.0 technology, and higher education is not exempt from its long reach. Libraries of all types are incorporating Web 2.0 features to attract users as well as to showcase library services. The Online Public Access Catalog (OPAC) has become more user-friendly with…

  8. Measurement of Crystalline Lens Volume During Accommodation in a Lens Stretcher

    PubMed Central

    Marussich, Lauren; Manns, Fabrice; Nankivil, Derek; Maceo Heilman, Bianca; Yao, Yue; Arrieta-Quintero, Esdras; Ho, Arthur; Augusteyn, Robert; Parel, Jean-Marie

    2015-01-01

    Purpose To determine if the lens volume changes during accommodation. Methods The study used data acquired on 36 cynomolgus monkey lenses that were stretched in a stepwise fashion to simulate disaccommodation. At each step, stretching force and dioptric power were measured and a cross-sectional image of the lens was acquired using an optical coherence tomography system. Images were corrected for refractive distortions and lens volume was calculated assuming rotational symmetry. The average change in lens volume was calculated and the relation between volume change and power change, and between volume change and stretching force, were quantified. Linear regressions of volume-power and volume-force plots were calculated. Results The mean (±SD) volume in the unstretched (accommodated) state was 97 ± 8 mm3. On average, there was a small but statistically significant (P = 0.002) increase in measured lens volume with stretching. The mean change in lens volume was +0.8 ± 1.3 mm3. The mean volume-power and volume-load slopes were −0.018 ± 0.058 mm3/D and +0.16 ± 0.40 mm3/g. Conclusions Lens volume remains effectively constant during accommodation, with changes that are less than 1% on average. This result supports a hypothesis that the change in lens shape with accommodation is accompanied by a redistribution of tissue within the capsular bag without significant compression of the lens contents or fluid exchange through the capsule. PMID:26161985

  9. Measurement of Crystalline Lens Volume During Accommodation in a Lens Stretcher.

    PubMed

    Marussich, Lauren; Manns, Fabrice; Nankivil, Derek; Maceo Heilman, Bianca; Yao, Yue; Arrieta-Quintero, Esdras; Ho, Arthur; Augusteyn, Robert; Parel, Jean-Marie

    2015-07-01

    To determine if the lens volume changes during accommodation. The study used data acquired on 36 cynomolgus monkey lenses that were stretched in a stepwise fashion to simulate disaccommodation. At each step, stretching force and dioptric power were measured and a cross-sectional image of the lens was acquired using an optical coherence tomography system. Images were corrected for refractive distortions and lens volume was calculated assuming rotational symmetry. The average change in lens volume was calculated and the relation between volume change and power change, and between volume change and stretching force, were quantified. Linear regressions of volume-power and volume-force plots were calculated. The mean (± SD) volume in the unstretched (accommodated) state was 97 ± 8 mm3. On average, there was a small but statistically significant (P = 0.002) increase in measured lens volume with stretching. The mean change in lens volume was +0.8 ± 1.3 mm3. The mean volume-power and volume-load slopes were -0.018 ± 0.058 mm3/D and +0.16 ± 0.40 mm3/g. Lens volume remains effectively constant during accommodation, with changes that are less than 1% on average. This result supports a hypothesis that the change in lens shape with accommodation is accompanied by a redistribution of tissue within the capsular bag without significant compression of the lens contents or fluid exchange through the capsule.

  10. 40 CFR 63.1653 - Opacity standards.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Opacity standards. No owner or operator shall cause emissions exiting from a shop due solely to operations... during any performance test, with the following exceptions: (a) Visible particulate emissions from a shop...

  11. Compliance among soft contact lens wearers.

    PubMed

    Kuzman, Tomislav; Kutija, Marija Barisić; Masnec, Sanja; Jandroković, Sonja; Mrazovac, Danijela; Jurisić, Darija; Skegro, Ivan; Kalauz, Miro; Kordić, Rajko

    2014-12-01

    Contact lens compliance is proven to be crucial for preventing lens wear-related complications because of the interdependence of the steps in lens care regime and their influence on lens system microbial contamination. Awareness of the patients' lens handling compliance as well as correct recognition of non-compliant behaviours is the basis for creating more targeted strategies for patient education. The aim of this study was to investigate compliance among soft contact lens (SCL) wearers in different aspects of lens care handling and wearing habits. In our research 50 asymptomatic lens wearers filled out a questionnaire containing demographic data, lens type, hygiene and wearing habits, lenses and lens care system replacement schedule and self-evaluation of contact lens handling hygiene. We established criteria of compliance according to available manufacturer's recommendations, prior literature and our clinical experience. Only 2 (4%) of patients were fully compliant SCL wearers. The most common non-compliant behaviours were insufficient lens solution soaking time (62%), followed by failure to daily exchange lens case solution and showering while wearing lenses. 44% of patients reported storing lenses in saline solution. Mean lens storage case replacement was 3.6 months, with up to 78% patients replacing lens case at least once in 3 months. Average grade in self evaluating level of compliance was very good (4 +/- 0.78) (from 1-poor level of hygiene to 5-great level of hygiene). Lens wearers who reported excessive daily lens wear and more than 10 years of lens wearing experience were also found to be less compliant with other lens system care procedures. (t = -2.99, df=47, p < 0.0045 and t = -2.33, df= 48, p < 0.024, respectively). Our study indicates that almost all patients had some degree of non-compliance in lens system maintenance steps. Most common non-compliant behaviours were the ones that are crucial for maintaining lens sterility and preventing infection

  12. Relationship of the actual thick intraocular lens optic to the thin lens equivalent.

    PubMed

    Holladay, J T; Maverick, K J

    1998-09-01

    To theoretically derive and empirically validate the relationship between the actual thick intraocular lens and the thin lens equivalent. Included in the study were 12 consecutive adult patients ranging in age from 54 to 84 years (mean +/- SD, 73.5 +/- 9.4 years) with best-corrected visual acuity better than 20/40 in each eye. Each patient had bilateral intraocular lens implants of the same style, placed in the same location (bag or sulcus) by the same surgeon. Preoperatively, axial length, keratometry, refraction, and vertex distance were measured. Postoperatively, keratometry, refraction, vertex distance, and the distance from the vertex of the cornea to the anterior vertex of the intraocular lens (AV(PC1)) were measured. Alternatively, the distance (AV(PC1)) was then back-calculated from the vergence formula used for intraocular lens power calculations. The average (+/-SD) of the absolute difference in the two methods was 0.23 +/- 0.18 mm, which would translate to approximately 0.46 diopters. There was no statistical difference between the measured and calculated values; the Pearson product-moment correlation coefficient from linear regression was 0.85 (r2 = .72, F = 56). The average intereye difference was -0.030 mm (SD, 0.141 mm; SEM, 0.043 mm) using the measurement method and +0.124 mm (SD, 0.412 mm; SEM, 0.124 mm) using the calculation method. The relationship between the actual thick intraocular lens and the thin lens equivalent has been determined theoretically and demonstrated empirically. This validation provides the manufacturer and surgeon additional confidence and utility for lens constants used in intraocular lens power calculations.

  13. Dialogue with an OPAC: How Visionary Was Swanson in 1964?

    ERIC Educational Resources Information Center

    Su, Shiao-Feng

    1994-01-01

    Traces the development of online public access catalogs (OPACs) and compares what has occurred with a 1964 article that outlined recommendations for a future card catalog. Subject access is emphasized, including Library of Congress Subject Headings, expansion of OPACs, user-friendly interfaces, new technologies, and current visions of the future…

  14. Interaction of intraocular lenses with fibronectin and human lens epithelial cells: Effect of chemical composition and aging.

    PubMed

    Tortolano, Lionel; Serrano, Carole; Jubeli, Emile; Saunier, Johanna; Yagoubi, Najet

    2015-12-01

    The aim of this study is to investigate in vitro interactions between hydrophobic acrylate intraocular lenses (IOLs) and their biological environment. The influence of lens chemical composition and aging on fibronectin (FN) adsorption and on IOLs cytotoxicity on human lens epithelial cells was examined. Cytotoxicity of acrylate monomers used in IOLs manufacture was also investigated. Four different IOLs were included in the study: Acrysof(®), Tecnis(®), EnVista(®), and iSert(®). Implants were artificially aged in a xenon arc chamber to simulate 2 years of light exposure. Fibronectin adsorption on IOL surface was quantified using ELISA and correlated to surface roughness determined with AFM. Direct contact cytotoxicity was determined with the MTT assay and cell morphology was observed with light microscopy. Results showed that fibronectin adsorption did not differ significantly among IOLs, whatever their chemical composition. Moreover, aging conditions did not impact fibronectin adsorption. All IOLs were biocompatible even after applying 2-year aging conditions, with cell viability higher than 70%. Five acrylate monomers appeared to be toxic in the range of concentrations tested, but no monomer release from the IOLs could be detected during accelerated 2-year incubation with saline solution. This study did not reveal an influence of chemical composition and aging on protein adsorption and on biocompatibility. © 2015 Wiley Periodicals, Inc.

  15. 77 FR 18709 - Quality Assurance Requirements for Continuous Opacity Monitoring Systems at Stationary Sources

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-03-28

    ... Quality Assurance Requirements for Continuous Opacity Monitoring Systems at Stationary Sources AGENCY... direct final rule titled ``Quality Assurance Requirements for Continuous Opacity Monitoring Systems at...--Quality Assurance Requirements for Continuous Opacity Monitoring Systems at Stationary Sources Docket, EPA...

  16. Ultrastructural characterization and Fourier analysis of fiber cell cytoplasm in the hyperbaric oxygen treated guinea pig lens opacification model.

    PubMed

    Freel, Christopher D; Gilliland, Kurt O; Mekeel, Harold E; Giblin, Frank J; Costello, M Joseph

    2003-04-01

    The structural characteristics of differentiated fiber cells in control and hyperbaric oxygen (HBO)-treated guinea pig lenses were examined by transmission electron microscopy (TEM). Emphasis was placed on cell damage, membrane integrity, and cytoplasmic texture. Given the faint gross opacities observed in HBO-treated lenses in previous studies, it was hypothesized that subtle but significant morphological differences due to oxidative damage exist between control and treated animals. Experimental animals received either 70 or 85 treatments with HBO (2.5 atm of 100% O(2) for 2.5 hr, 3 times per week for 5-7 months). All specimens were obtained within 24 hr of death. Freshly cut Vibratome lens sections were fixed and processed for low and high-magnification thin-section TEM analysis. Cytoplasmic texture was analyzed using Fourier and autocorrelation image processing techniques. Low-magnification analysis revealed relatively insignificant differences in general appearance between the fiber cells of the inner fetal and embryonic nuclei in control and HBO-treated guinea pigs. Both groups demonstrated cells of similar morphology with equivalent membrane complexity and homogeneous cytoplasmic texture. Evidence of any major cellular damage or extracellular space debris was not obvious. High-magnification analysis of the cytoplasm of the treated lenses exhibited a mild, yet detectable increase in texture compared with controls and was confirmed by Fourier analysis. Cytoplasmic texture increased in complexity with additional treatments. The absence of major cellular damage in the lenses of HBO-treated animals suggests a less conspicuous source of light scattering. The small changes in cytoplasmic organization observed between treated and control animals may entirely account for the increase in nuclear light scattering observed by slit lamp. The results obtained with this guinea pig/HBO model parallel many of the morphological data associated with human nuclear cataracts. The

  17. We Never Have to Say Goodbye: Finding a Place for OPACS in Discovery Environments

    ERIC Educational Resources Information Center

    Matthews, J. Greg

    2009-01-01

    It is easy to lament the shortcomings of traditional online public access catalogs (OPACs) in the Google Age. Users cannot, for example, usually input a snippet of a long-forgotten pop song's chorus into an online library catalog and almost instantly retrieve a relevant result along with hundreds of other options. On the other hand, should OPACs…

  18. Effects of injection pressure and injection timing to exhaust gas opacity for a conventional indirect diesel engine

    NASA Astrophysics Data System (ADS)

    Budiman, Agus; Majid, Akmal Irfan; Pambayun, Nirmala Adhi Yoga; Yuswono, Lilik Chaerul; Sukoco

    2016-06-01

    In relation to pollution control and environmental friendliness, the quality of exhaust gas from diesel engine needs to be considered. The influences of injection pressure and timing to exhaust gas opacity were investigated. A series of experiments were conducted in a one-cylinder conventional diesel engine with a naturally aspirated system and indirect injection. The default specification of injection pressure was 120 kg/cm2. To investigate the injection pressure, the engine speed was retained on 1000 rpm with pressure variations from 80 to 215 kg/cm2. On the other hand, the various injection timing (8, 10, 12, 16 degrees before TDC point and exact 18 degrees before TDC point) were used to determine their effects to exhaust gas opacity. In this case, the engine speed was varied from 1000 to 2400 rpm. The injector tester was used to measure injection pressure whereas the exhaust gas opacity was determined by the smoke meter. Those data were also statistically analyzed by product moment correlation. As the results, the injection pressure of diesel engine had a non-significant positive correlation to the exhaust gas opacity with r = 0.113 and p > 5 %. Injection pressure should be adjusted to the specification listed on the diesel engine as if it was too high or too low will lead to the higher opacity. Moreover, there was a significant positive correlation between injection timing and the exhaust gas opacity in all engine speeds.

  19. A high excitation magnetic quadrupole lens quadruplet incorporating a single octupole lens for a low spherical aberration probe forming lens system

    NASA Astrophysics Data System (ADS)

    Dou, Yanxin; Jamieson, David N.; Liu, Jianli; Li, Liyi

    2018-03-01

    This paper describes the design of a new probe forming lens system consisting of a high excitation magnetic quadrupole lens quadruplet that incorporates a single magnetic octupole lens. This system achieves both a high demagnification and a low spherical aberration compared to conventional high excitation systems and is intended for deployment for the Harbin 300 MeV proton microprobe for applications in space science and ion beam therapy. This relative simplicity of the ion optical design to include a single octupole lens minimizes the risks associated with the constructional and operational precision usually needed for the probe forming lens system and this system could also be deployed in microprobe systems that operate with less magnetically rigid ions. The design of the new system is validated with reference to two independent ion optical computer codes.

  20. Measuring the opacity of stellar interior matter in terrestrial laboratories

    NASA Astrophysics Data System (ADS)

    Bailey, James

    2015-11-01

    How does energy propagate from the core to the surface of the Sun, where it emerges to warm the Earth? Nearly a century ago Eddington recognized that the attenuation of radiation by stellar matter controls the internal structure of stars like the sun. Opacities for high energy density (HED) matter are challenging to calculate because accurate and complete descriptions of the energy levels, populations, and plasma effects such as continuum lowering and line broadening are needed for partially ionized atoms. This requires approximations, in part because billions of bound-bound and bound-free electronic transitions can contribute to the opacity. Opacity calculations, however, have never been benchmarked against laboratory measurements at stellar interior conditions. Laboratory opacity measurements were limited in the past by the challenges of creating and diagnosing sufficiently large and uniform samples at the extreme conditions found inside stars. In research conducted over more than 10 years, we developed an experimental platform on the Z facility and measured wavelength-resolved iron opacity at electron temperatures Te = 156-195 eV and densities ne = 0.7-4.0 x 1022 cm-3 - conditions very similar to the radiation/convection boundary zone within the Sun. The wavelength-dependent opacity in the 975-1775 eV photon energy range is 30-400% higher than models predict. This raises questions about how well we understand the behavior of atoms in HED plasma. These measurements may also help resolve decade-old discrepancies between solar model predictions and helioseismic observations. This talk will provide an overview of the measurements, investigations of possible errors, and ongoing experiments aimed at testing hypotheses to resolve the model-data discrepancy. Sandia is a multiprogram laboratory operated by Sandia Corporation, a Lockheed Martin Company, for the United States Department of Energy under contract DE-AC04-94AL85000.

  1. Web-Based OPACs in Indian Academic Libraries: A Functional Comparison

    ERIC Educational Resources Information Center

    Kapoor, Kanta; Goyal, O. P.

    2007-01-01

    Purpose: The paper seeks to provide a comparative analysis of the functionality of five web-based OPACs available in Indian academic libraries. Design/methodology/approach: Same-topic searches were carried out by three researchers on the web-based OPACs of Libsys, VTLS's iPortal, NewGenLib, Troodon, and Alice for Windows, implemented in five…

  2. [The effect of UV-irradiation on telomerase activity and other stress-related proteins in human lens epithelial cells].

    PubMed

    Wu, Zhi-hong; Zhang, Jin-song

    2005-05-01

    To investigate the changes and the role of telomerase activity and other stress-related proteins in the process of UV-induced DNA damage and repair in human lens epithelial cells. Human lens epithelial cells were irradiated at UV-doses 0.0 (control group) and 0.5, 1.5, 2.5, 3.5, 5.0, 7.5, 10.0 mJ/cm(2) (treated 1-7 group). Telomerase activity was determined by Telomerase Repeat Amplification Protocol-Enzyme Linked Immunosorbent Assay (TRAP-ELISA), p53, growth arrest and DNA damage inducible (GADD45), proliferating cell nuclear antigen (PCNA) and p16 protein levels were analyzed by Western blotting. Telomerase activity in control group and treated 1-7 group showed increased tendency, the differences of telomerase activity in 8 groups were significantly (P < 0.01). The expression of p53, GADD45, PCNA, p16 proteins showed increased tendency in experimental group, comparing with the control group, there were significant difference (P < 0.01). During UV-induced DNA damage and repair in human lens epithelial cells, telomerase activity was upregulated and the expression of stress-related proteins levels was increased. Upregulated telomerase activity may play both a protective and a proliferative role in human lens epithelial cells. Increased stress-related proteins level is critic in UV-induced DNA damage and repair in human lens epithelial. Increased telomerase activity is associated with increased levels of the stress-related proteins.

  3. Radiative opacities of iron using a difference algebraic converging method at temperatures near solar convection zone

    NASA Astrophysics Data System (ADS)

    Fan, Zhixiang; Sun, Weiguo; Zhang, Yi; Fu, Jia; Hu, Shide; Fan, Qunchao

    2018-03-01

    An interpolation method named difference algebraic converging method for opacity (DACMo) is proposed to study the opacities and transmissions of metal plasmas. The studies on iron plasmas at temperatures near the solar convection zone show that (1) the DACMo values reproduce most spectral structures and magnitudes of experimental opacities and transmissions. (2) The DACMo can be used to predict unknown opacities at other temperature Te' and density ρ' using the opacity constants obtained at ( Te , ρ). (3) The DACMo may predict reasonable opacities which may not be available experimentally but the least-squares (LS) method does not. (4) The computational speed of the DACMo is at least 10 times faster than that of the original difference converging method for opacity.

  4. 40 CFR 63.1653 - Opacity standards.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Silicomanganese § 63.1653 Opacity standards. No owner or operator shall cause emissions exiting from a shop due... particulate emissions from a shop due solely to operation of a semi-closed submerged arc furnace, may exceed...

  5. 40 CFR 63.1653 - Opacity standards.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Silicomanganese § 63.1653 Opacity standards. No owner or operator shall cause emissions exiting from a shop due... particulate emissions from a shop due solely to operation of a semi-closed submerged arc furnace, may exceed...

  6. 40 CFR 63.1653 - Opacity standards.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Silicomanganese § 63.1653 Opacity standards. No owner or operator shall cause emissions exiting from a shop due... particulate emissions from a shop due solely to operation of a semi-closed submerged arc furnace, may exceed...

  7. A Case of Bilateral Descemet's Membrane and Subepithelial Opacity: In vivo Laser Confocal Microscopic Study.

    PubMed

    Hatta, Yukiko; Yokogawa, Hideaki; Kobayashi, Akira; Torisaki, Makoto; Sugiyama, Kazuhisa

    2013-01-01

    To report the in vivo laser confocal microscopy findings from a patient with Descemet's membrane and subepithelial opacity OU. A healthy 41-year-old male with Descemet's membrane and subepithelial opacity OU was studied. Routine ophthalmic examination, standard slit-lamp biomicroscopy, and in vivo laser confocal microscopic analysis of the entire corneal layer were performed. Slit-lamp biomicroscopy revealed subepithelial opacity in the mid-peripheral to peripheral cornea and numerous opacities located at the level of Descemet's membrane. It was difficult to distinguish the precise histological location of the opacity. In vivo laser confocal microscopy showed numerous hyperreflective particles in the subepithelium to superficial stroma and hyperreflectivity of Descemet's membrane. No abnormalities could be detected in the epithelial cell layer, midstromal layer, deep stromal layer, or endothelial cell layer. Although the origin of the corneal opacities was unclear, in vivo laser confocal microscopy was useful for observing microstructural abnormalities in a case of Descemet's membrane and subepithelial opacity.

  8. A Case of Bilateral Descemet's Membrane and Subepithelial Opacity: In vivo Laser Confocal Microscopic Study

    PubMed Central

    Hatta, Yukiko; Yokogawa, Hideaki; Kobayashi, Akira; Torisaki, Makoto; Sugiyama, Kazuhisa

    2013-01-01

    Purpose To report the in vivo laser confocal microscopy findings from a patient with Descemet's membrane and subepithelial opacity OU. Case Report A healthy 41-year-old male with Descemet's membrane and subepithelial opacity OU was studied. Routine ophthalmic examination, standard slit-lamp biomicroscopy, and in vivo laser confocal microscopic analysis of the entire corneal layer were performed. Slit-lamp biomicroscopy revealed subepithelial opacity in the mid-peripheral to peripheral cornea and numerous opacities located at the level of Descemet's membrane. It was difficult to distinguish the precise histological location of the opacity. In vivo laser confocal microscopy showed numerous hyperreflective particles in the subepithelium to superficial stroma and hyperreflectivity of Descemet's membrane. No abnormalities could be detected in the epithelial cell layer, midstromal layer, deep stromal layer, or endothelial cell layer. Conclusion Although the origin of the corneal opacities was unclear, in vivo laser confocal microscopy was useful for observing microstructural abnormalities in a case of Descemet's membrane and subepithelial opacity. PMID:23626574

  9. Systematic measurements of opacity dependence on temperature, density, and atomic number at stellar interior conditions

    NASA Astrophysics Data System (ADS)

    Nagayama, Taisuke

    2017-10-01

    Model predictions for iron opacity are notably different from measurements performed at matter conditions similar to the boundary between the solar radiation and convection zones. The calculated iron opacities have narrower spectral lines, weaker quasi-continuum at short wavelength, and deeper opacity windows than the measurements. If correct, these measurements help resolve a decade old problem in solar physics. A key question is therefore: What is responsible for the model-data discrepancy? The answer is complex because the experiments are challenging and opacity theories depend on multiple entangled physical processes such as the influence of completeness and accuracy of atomic states, line broadening, contributions from myriad transitions from excited states, and multi-photon absorption processes. To help determine the cause of this discrepancy, a systematic study of opacity variation with temperature, density, and atomic number is underway. Measurements of chromium, iron, and nickel opacities have been performed at two different temperatures and densities. The collection of measured opacities provides constraints on hypotheses to explain the discrepancy. We will discuss implications of measured opacities, experimental errors, and possible opacity model refinements. Sandia National Laboratories is a multi-mission laboratory managed and operated by National Technology and Engineering Solutions of Sandia, LLC., a wholly owned subsidiary of Honeywell International, Inc., for the U.S. Department of Energy's National Nuclear Security Administration under contract DE-NA0003525.

  10. ENERGY AND ANGULAR DEPENDENCE OF RADIOPHOTOLUMINESCENT GLASS DOSEMETERS FOR EYE LENS DOSIMETRY.

    PubMed

    Silva, E H; Knežević, Ž; Struelens, L; Covens, P; Ueno, S; Vanhavere, F; Buls, N

    2016-09-01

    Recent studies demonstrated that lens opacities can occur at lower radiation doses than previously accepted. In view of these studies, the International Commission of Radiological Protection recommended in 2011 to reduce the eye lens dose limit from 150 mSv/y to 20 mSv/y. This implies in the need of monitoring doses received by the eye lenses. In this study, small rod radiophotoluminescent glass dosemeters (GD-300 series; AGC, Japan) were characterized in terms of their energy (ISO 4037 X-rays narrow spectrum series, S-Cs and S-Co) and angular dependence (0  up to 90 degrees, with 2 ISO energies: N-60 and S-Cs). All acquisitions were performed at SCK•CEN-Belgium, using the ORAMED proposed cylindrical phantom. For selected energies (N-60, N-80, N-100, N-120 and N-250), the response of dosemeters irradiated on the ISO water slab phantom, at the Ruđer Bošković Institute-Croatia, was compared to those irradiated on the cylindrical phantom. GD-300 series showed good energy dependence, relative to S-Cs, on the cylindrical phantom. From 0 up to 45 degrees, the dosemeters showed no significant angular dependence, regardless whether they were tested when placed vertically or horizontally on the cylindrical phantom. However, at higher angles, some angular dependence was observed, mainly when the dosemeters were irradiated with low-energy photons (N-60). Results showed that GD-300 series have good properties related to Hp(3), although some improvements may be necessary. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  11. AMO Teledioptric System for age-related macular degeneration

    NASA Astrophysics Data System (ADS)

    Chou, Jim-Son; Ting, Albert C.

    1994-05-01

    A 2.5 X magnification system consisting of a two-zone intraocular implant and a spectacle was developed, tested, and clinically tried by fifty patients with cataract ad age-related macular degeneration. Optical bench testing results and clinical data confirmed that the field of view of the system was 2.6 times wider than an equivalent external telescope. The study also demonstrated that the implant itself was clinically equivalent to a standard monofocal intraocular lens for cataract. The clinical study indicated that higher magnification without compromising the compactness and optical quality was needed as the disease progressed. Also, a sound vision rehabilitation process is important to provide patients the full benefits of the system.

  12. The Iron Project & Opacity Project: Photoionization, radiative transitions of iron ions for Opacities and Astrophysical Applications

    NASA Astrophysics Data System (ADS)

    Zhao, Lianshui; Nahar, Sultana; Pradhan, Anil; Eissner, Werner

    2017-04-01

    We have carried out converged close coupling R-Matrix (CCC-RM) calculations for photoionization of Ne-like Fe XVII and demonstrate orders-of-magnitude enhancements in cross section due to successive core excitations. Convergence criteria are: (i) inclusion of sufficient number of residual ion Fe XVIII core states, (ii) high-resolution of myriad autoionizing resonances, and (iii) high-energy cross sections. We discuss verification of the conventional oscillator strength sum-rule in limited energy regions for bound-free plasma opacity. High energy cross sections are also under investigation. In order to obtain solar iron opacity at the boundary of the radiative and convection zones, we have studied the residual ion states that should provide convergence of resonances of other L-shell iron ions, Fe XIV - Fe XX, in the plasma region. Preliminary results from R-matrix calculations of photoionization cross sections will be reported. NSF, DOE, OSC.

  13. Combined 23-gauge transconjunctival vitrectomy and scleral fixation of intraocular lens without conjunctival dissection in managing lens complications.

    PubMed

    Yeung, Ling; Wang, Nan-Kai; Wu, Wei-Chi; Chen, Kuan-Jen

    2018-04-23

    To evaluate the safety and efficacy of combined 23-gauge transconjunctival pars plana vitrectomy and scleral fixation of intraocular lens (IOL) without conjunctival dissection. A retrospective study in Chang Gung Memorial Hospital, Keelung and Taoyuan, Taiwan. Patients receiving combined 23-gauge transconjunctival pars plana vitrectomy and scleral fixation of IOL without conjunctival dissection were enrolled. The ocular findings, causes of lens complication, surgical procedures, type of IOL used, and complications were documented. We included 40 eyes from 39 patients (27 male, 12 female) with a mean age of 59.5 [standard deviation (±) 14.8] years old. The mean follow-up duration was 6.8 ± 5.4 months. The cause of lens complications was ocular trauma in 24 (60%) eyes, cataract surgery complications in 11 (28%) eyes, and spontaneous subluxation of crystalline lens in 5 (13%) eyes. The overall best corrected visual acuity (BCVA) (logMAR) improved from 1.359 ± 0.735 to 0.514 ± 0.582 (p < 0.001). The BCVA also improved significantly in each group with different causes of lens complications. Preoperative BCVA was the only factor associated with the postoperative visual outcome (p = 0.008). Most surgery-related complications were self-limited, including mild vitreous hemorrhage (5%), microhyphema (5%), transient elevated intraocular pressure (3%), and transient hypotony (3%). Cystoid macular edema and IOL decentration was found in 3 (8%) eyes and 1 (3%) eye respectively. Combined 23-gauge transconjunctival vitrectomy and scleral fixation of IOL without conjunctival dissection is effective and safe in managing a wide variety of lens complications, with good postoperative comfort and visual recovery. Retrospective study, not applicable.

  14. Ultrashort-pulse lasers treating the crystalline lens: will they cause vision-threatening cataract? (An American Ophthalmological Society thesis).

    PubMed

    Krueger, Ronald R; Uy, Harvey; McDonald, Jared; Edwards, Keith

    2012-12-01

    To demonstrate that ultrashort-pulse laser treatment in the crystalline lens does not form a focal, progressive, or vision-threatening cataract. An Nd:vanadate picosecond laser (10 ps) with prototype delivery system was used. Primates: 11 rhesus monkey eyes were prospectively treated at the University of Wisconsin (energy 25-45 μJ/pulse and 2.0-11.3M pulses per lens). Analysis of lens clarity and fundus imaging was assessed postoperatively for up to 4½ years (5 eyes). Humans: 80 presbyopic patients were prospectively treated in one eye at the Asian Eye Institute in the Philippines (energy 10 μJ/pulse and 0.45-1.45M pulses per lens). Analysis of lens clarity, best-corrected visual acuity, and subjective symptoms was performed at 1 month, prior to elective lens extraction. Bubbles were immediately seen, with resolution within the first 24 to 48 hours. Afterwards, the laser pattern could be seen with faint, noncoalescing, pinpoint micro-opacities in both primate and human eyes. In primates, long-term follow-up at 4½ years showed no focal or progressive cataract, except in 2 eyes with preexisting cataract. In humans, <25% of patients with central sparing (0.75 and 1.0 mm radius) lost 2 or more lines of best spectacle-corrected visual acuity at 1 month, and >70% reported acceptable or better distance vision and no or mild symptoms. Meanwhile, >70% without sparing (0 and 0.5 mm radius) lost 2 or more lines, and most reported poor or severe vision and symptoms. Focal, progressive, and vision-threatening cataracts can be avoided by lowering the laser energy, avoiding prior cataract, and sparing the center of the lens.

  15. Molecular opacities for exoplanets.

    PubMed

    Bernath, Peter F

    2014-04-28

    Spectroscopic observations of exoplanets are now possible by transit methods and direct emission. Spectroscopic requirements for exoplanets are reviewed based on existing measurements and model predictions for hot Jupiters and super-Earths. Molecular opacities needed to simulate astronomical observations can be obtained from laboratory measurements, ab initio calculations or a combination of the two approaches. This discussion article focuses mainly on laboratory measurements of hot molecules as needed for exoplanet spectroscopy.

  16. A new in vitro method to evaluate radio-opacity of endodontic sealers.

    PubMed

    Malka, V B; Hochscheidt, G L; Larentis, N L; Grecca, F S; Fontanella, V R C; Kopper, P M P

    2015-01-01

    To evaluate a new method for assessing the radio-opacity of endodontic sealers and to compare radio-opacity values with a well-established standard method. The sealers evaluated in this study were AH Plus(®) (Dentsply DeTrey GmbH, Konstanz, Germany), Endo CPM Sealer (EGEO SRL, Buenos Aires, Argentina) and MTA Fillapex(®) (Angelus Dental Products Industry S/A, Londrina, Parana, Brazil). Two methods were used to evaluate radio-opacity: (D) standard discs and (S) a tissue simulator. For (D), ten standard discs were prepared for each sealer and were radiographed using Digora(®) phosphor storage plates (Soredex; Orion Corporation, Helsinki, Finland), alongside an aluminium stepwedge. For (S), polyethylene tubes filled with sealer (n = 10 for each) were radiographed inside the simulator as described. The digital images were analysed using Adobe Photoshop(®) software v. 10.0 (Adobe Systems, San Jose, CA). To compare the radio-opacity among the sealers, the data were analysed by ANOVA and Tukey's test, and to compare methods, they were analysed by the Mann-Whitney U test. To compare the data obtained from dentin and sealers in method (S), Student's paired t-test was used (=0.05). In both methods, the sealers showed significant differences, according to the following decreasing order: AH Plus, MTA Fillapex and Endo CPM. In (D), MTA Fillapex and Endo CPM showed less radio-opacity than aluminium. For all of the materials, the radio-opacity was higher in (S) than in (D). Compared with dentin, all of the materials were more radio-opaque. The comparison of the two assessment methods for sealer radio-opacity testing validated the use of a tissue simulator block.

  17. Simulations of the National Ignition Facility Opacity Sample

    NASA Astrophysics Data System (ADS)

    Martin, M. E.; London, R. A.; Heeter, R. F.; Dodd, E. S.; Devolder, B. G.; Opachich, Y. P.; Liedahl, D. A.; Perry, T. S.

    2017-10-01

    A platform to study the opacity of high temperature materials at the National Ignition Facility has been developed. Experiments to study the opacity of materials relevant to inertial confinement fusion and stellar astrophysics are being conducted. The initial NIF experiments are focused on reaching the same plasma conditions (T >150 eV and Ne >= 7 ×1021 cm-3) , for iron, as those achieved in previous experiments at Sandia National Laboratories' (SNL) Z-facility which have shown discrepancies between opacity theory and experiment. We developed a methodology, using 1D HYDRA simulations, to study the effects of tamper thickness on the conditions of iron-magnesium samples. We heat the sample using an x-ray drive from 2D LASNEX hohlraum simulations. We also use this methodology to predict sample uniformity and expansion for comparison with experimental data. This work was performed under the auspices of the U.S. Department of Energy by Lawrence Livermore National Laboratory under Contract DE-AC52-07NA27344. Lawrence Livermore National Security, LLC.

  18. Expanding the Therapy Paradigm with Queer Couples: A Relational Intersectional Lens.

    PubMed

    Addison, Sheila M; Coolhart, Deborah

    2015-09-01

    North American and global cultures in general-and the field of Couple and Family Therapy in particular-have made significant strides toward recognizing and validating LGBTQ identities and relationships. However, clinical assessment and conceptualization of queer couples still lack the complexity needed to encompass the issues involved in treatment. Existing literature provides clinicians a basic understanding of queer couples and the dynamics that make them unique from nonqueer couples. However, much of this knowledge has been normed on White middle-class couples and has rarely included couples with transgender or bisexual members. This article invites clinicians and researchers to apply a feminist model of intersectionality to understand queer couples. Our proposed intersectional lens considers multiple axes of identity and power and their interrelationships (Crenshaw, 1989, 1991). We argue that intersectionality is important for understanding all identities, whether privileged or marginalized (Falicov, 2003). This application of the concept of intersectionality is unique in its relational focus, emphasizing how partners' complex individual identities overlap with and intersect with one another. Additionally, this lens considers how the therapists' and clients' multidimensional identities intersect. Three case studies are presented to illustrate application of the intersectional lens. In each case, exploring the partners' multiple social locations, their influences on one another, and the therapist's intersections of identity all proved critical to the direction of therapy. © 2015 Family Process Institute.

  19. Aberration design of zoom lens systems using thick lens modules.

    PubMed

    Zhang, Jinkai; Chen, Xiaobo; Xi, Juntong; Wu, Zhuoqi

    2014-12-20

    A systematic approach for the aberration design of a zoom lens system using a thick lens module is presented. Each component is treated as a thick lens module at the beginning of the design. A thick lens module refers to a thick lens component with a real lens structure, like lens materials, lens curvatures, lens thicknesses, and lens interval distances. All nine third-order aberrations of a thick lens component are considered during the design. The relationship of component aberrations in different zoom positions can be approximated from the aberration shift. After minimizing the aberrations of the zoom lens system, the nine third-order aberrations of every lens component can be determined. Then the thick lens structure of every lens component can be determined after optimization according to their first-order properties and third-order aberration targets. After a third optimization for minimum practical third-order aberrations of a zoom lens system, the aberration design using the thick lens module is complete, which provides a practical zoom lens system with thick lens structures. A double-sided telecentric zoom lens system is designed using the thick lens module in this paper, which shows that this method is practical for zoom lens design.

  20. Growth of the eye lens: I. Weight accumulation in multiple species

    PubMed Central

    2014-01-01

    Purpose To examine the accumulation of wet and/or dry weight in the ocular lens as a function of age in different species. Methods Wet weights and/or fixed dry weights were obtained from measurements in the author’s laboratory and from the literature for over 14,000 lenses of known-ages, representing 130 different species. Various algorithms were tested to determine the most suitable for describing the relationship between lens weight and age. Results For 126 of the species examined, lens growth is continuous throughout life but asymptotic and can be reasonably described with a single logistic equation, W=Wm e-(k/A), where W is lens wet or dry weight; Wm is the maximum asymptotic weight, k is the logistic growth constant and A is the time from conception. For humans, elephants, hippopotami, minks, wild goats and woodchucks, lens growth appears to be biphasic. No gender differences could be detected in the lens weights for 70 species but male lenses are reportedly 10% larger than those of females in northern fur seals and pheasants. Dry weight accumulation is faster than that for wet weight in all species except birds and reptiles where the rates are the same. Low lens growth rates are associated with small animals with short gestation periods and short life spans. Conclusions Lens growth is continuous throughout life and, for most species, is independent of gender. For most, growth takes place through a monophasic asymptotic mode and is unaffected by events such as hibernation. This makes lens weight measurement a reliable tool for age determination of species culled in the wild. Compaction of the growing lens generates different properties, appropriate to an animal's lifestyle. How these events are controlled remains to be established. PMID:24715758

  1. FIRST NEW SOLAR MODELS WITH OPAS OPACITY TABLES

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Le Pennec, M.; Turck-Chièze, S.; Salmon, S.

    Stellar seismology appears more and more as a powerful tool for a better determination of the fundamental properties of solar-type stars. However, the particular case of the Sun is still challenging. For about a decade now, the helioseismic sound-speed determination has continued to disagree with the standard solar model (SSM) prediction, questioning the reliability of this model. One of the sources of uncertainty could be in the treatment of the transport of radiation from the solar core to the surface. In this Letter, we use the new OPAS opacity tables, recently available for solar modeling, to address this issue. Wemore » discuss first the peculiarities of these tables, then we quantify their impact on the solar sound-speed and density profiles using the reduced OPAS tables taken on the grids of the OPAL ones. We use the two evolution codes, Modules for Experiments in Stellar Astrophysics and Code Liégeois d’Evolution Stellaire, that led to similar conclusions in the solar radiative zone. In comparison to commonly used OPAL opacity tables, the new solar models are computed for the most recent photospheric composition with OPAS tables and present improvements to the location of the base of the convective zone and to the description of the solar radiative zone in comparison to the helioseismic observations, even if the differences in the Rosseland mean opacity do not exceed 6%. We finally carry out a comparison to a solar model computed with the OP opacity tables.« less

  2. Molecular opacities for exoplanets

    PubMed Central

    Bernath, Peter F.

    2014-01-01

    Spectroscopic observations of exoplanets are now possible by transit methods and direct emission. Spectroscopic requirements for exoplanets are reviewed based on existing measurements and model predictions for hot Jupiters and super-Earths. Molecular opacities needed to simulate astronomical observations can be obtained from laboratory measurements, ab initio calculations or a combination of the two approaches. This discussion article focuses mainly on laboratory measurements of hot molecules as needed for exoplanet spectroscopy. PMID:24664921

  3. Population-based Incidence of Intraocular Lens Exchange in Olmsted County, Minnesota.

    PubMed

    Bothun, Erick D; Cavalcante, Lilian C B; Hodge, David O; Patel, Sanjay V

    2018-03-01

    To determine the population-based incidence of pseudophakic intraocular lens exchange in Olmsted County, Minnesota. Retrospective review of a population-based cohort. Patients undergoing pseudophakic intraocular lens exchange in Olmsted County, Minnesota, between January 1, 1986 and December 31, 2016 were identified from the Rochester Epidemiology Project medical record linkage system. Indications and outcomes were determined, and the incidence rate was calculated as cases per 1 000 000 person-years. Poisson regression analysis was used to assess changes in incidence over time, and the cumulative probability of needing a lens exchange was estimated by Kaplan-Meier analysis. Eighty cases of intraocular lens exchange were identified, yielding an overall age- and sex-adjusted incidence rate of 28.4 per million (confidence interval [CI], 22.1-34.7), which increased over the study period (P = .04). The 30-year cumulative probability of intraocular lens exchange among patients undergoing cataract surgery was 1.5% (CI, 0.6%-2.4%), increasing at a relatively constant rate. Dislocated lenses accounted for 72.5% of lens exchanges. Unplanned refractive outcome of primary cataract surgery and uveitis-glaucoma-hyphema syndrome from squared-edged haptics emerged as newer indications for intraocular lens exchange. The population-based incidence of pseudophakic intraocular lens exchange has increased over the last 30 years, and can be explained by the increase in incidence rate of cataract surgery over the same period. Surgeons should be aware of emerging indications of intraocular lens exchange, which reflect changes in lens design and increasing expectations of refractive outcomes. Copyright © 2017 Elsevier Inc. All rights reserved.

  4. The retina/RPE proteome in chick myopia and hyperopia models: Commonalities with inherited and age-related ocular pathologies

    PubMed Central

    Riddell, Nina; Faou, Pierre; Murphy, Melanie; Giummarra, Loretta; Downs, Rachael A.; Rajapaksha, Harinda

    2017-01-01

    Purpose Microarray and RNA sequencing studies in the chick model of early optically induced refractive error have implicated thousands of genes, many of which have also been linked to ocular pathologies in humans, including age-related macular degeneration (AMD), choroidal neovascularization, glaucoma, and cataract. These findings highlight the potential relevance of the chick model to understanding both refractive error development and the progression to secondary pathological complications. The present study aimed to determine whether proteomic responses to early optical defocus in the chick share similarities with these transcriptome-level changes, particularly in terms of dysregulation of pathology-related molecular processes. Methods Chicks were assigned to a lens condition (monocular +10 D [diopters] to induce hyperopia, −10 D to induce myopia, or no lens) on post-hatch day 5. Biometric measures were collected following a further 6 h and 48 h of rearing. The retina/RPE was then removed and prepared for liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-ESI-MS/MS) on an LTQ-Orbitrap Elite. Raw data were processed using MaxQuant, and differentially abundant proteins were identified using moderated t tests (fold change ≥1.5, Benjamini-Hochberg adjusted p<0.05). These differentially abundant proteins were compared with the genes and proteins implicated in previous exploratory transcriptome and proteomic studies of refractive error, as well as the genes and proteins linked to the ocular pathologies listed above for which myopia or hyperopia are risk factors. Finally, gene set enrichment analysis (GSEA) was used to assess whether gene sets from the Human Phenotype Ontology database were enriched in the lens groups relative to the no lens groups, and at the top or bottom of the protein data ranked by Spearman’s correlation with refraction at 6 and 48 h. Results Refractive errors of −2.63 D ± 0.31 D (mean ± standard error, SE) and 3

  5. A transgenic animal model of osmotic cataract. Part 1: over-expression of bovine Na+/myo-inositol cotransporter in lens fibers.

    PubMed

    Cammarata, P R; Zhou, C; Chen, G; Singh, I; Reeves, R E; Kuszak, J R; Robinson, M L

    1999-07-01

    and subcapsular fibers of the central zone, whereas the lens epithelium appeared morphologically normal. The lenticular changes, initiated early during lens development in TG MLR21 embryos, result in severe bilateral nuclear cataracts readily observable in neonates under normal rearing and dietary conditions. In contrast, TG MLR14 pups reared under standard conditions produced no lens opacity. Lens fiber swelling and related cataractous outgrowth positively correlated to the degree of lens bSMIT gene expression and intralenticular myo-inositol content. The affected (i.e., swollen) lens fibers appeared to be unable to cope with the water stress generated by the transgene-induced over-accumulation of myo-inositol and, as a result of this inability to osmoregulate, suffered osmotic damage due to water influx.

  6. The influence of urban area opacity on biologically active UV-B irradiance

    NASA Astrophysics Data System (ADS)

    Chubarova, Nataly; Rozental', Victor

    2013-04-01

    The study of UV irradiance changes in urban area is an essential problem due to the significant effect of UV irradiance on human health which can be positive (vitamin D synthesis) and negative (erythema, skin cancer, eye damage). According to the results of several experiments within the Moscow megacity we studied the effects of urban area opacity on the different types of biologically active UV-B irradiance on the base of a specially developed mobile photometric complex snd additional measurements of the urban opacity by Nikon Fisheye Converter FC-E8. We analyzed both the level of erythemally-active irradiance and the UV eye damaging radiation using the broadband UVB-1 YES pyranometer calibrated against ultraviolet spectroradiometer Bentham DTM-300 of the Medical University of Innsbruck (courtesy of Dr. M.Blumthaler). In order to estimate the effects of the urban opacity the measurements were normalized on similar measurements at the Meteorological Observatory of Moscow State University with zero opacity. This ratio is defined as an urban radiative transmittance (URT). Different atmospheric conditions were considered. In cloudy conditions the effect of opacity on URT is much less than that in conditions when the sun disk is open from clouds. We revealed some spectral features in transmittance of biologically active UV-B irradiance which is characterized by higher URT variations in overcast cloudy conditions due to more intensive scattering and smaller direct solar radiation component. In the absence of cloudiness the effect of opacity was studied for open and screening solar disk conditions. We obtained much higher URT in UVB spectral region compared with that for total solar irradiance for screening solar disk conditions with a significant URT dependence on the opacity only in UVB spectral region. No URT dependence was obtained for total solar irradiance in these conditions. Some model calculations were fulfilled to match the experimental results.

  7. A new in vitro method to evaluate radio-opacity of endodontic sealers

    PubMed Central

    Malka, V B; Hochscheidt, G L; Larentis, N L; Grecca, F S; Kopper, P M P

    2015-01-01

    Objectives: To evaluate a new method for assessing the radio-opacity of endodontic sealers and to compare radio-opacity values with a well-established standard method. Methods: The sealers evaluated in this study were AH Plus® (Dentsply DeTrey GmbH, Konstanz, Germany), Endo CPM Sealer (EGEO SRL, Buenos Aires, Argentina) and MTA Fillapex® (Angelus Dental Products Industry S/A, Londrina, Parana, Brazil). Two methods were used to evaluate radio-opacity: (D) standard discs and (S) a tissue simulator. For (D), ten standard discs were prepared for each sealer and were radiographed using Digora® phosphor storage plates (Soredex; Orion Corporation, Helsinki, Finland), alongside an aluminium stepwedge. For (S), polyethylene tubes filled with sealer (n = 10 for each) were radiographed inside the simulator as described. The digital images were analysed using Adobe Photoshop® software v. 10.0 (Adobe Systems, San Jose, CA). To compare the radio-opacity among the sealers, the data were analysed by ANOVA and Tukey's test, and to compare methods, they were analysed by the Mann–Whitney U test. To compare the data obtained from dentin and sealers in method (S), Student's paired t-test was used (=0.05). Results: In both methods, the sealers showed significant differences, according to the following decreasing order: AH Plus, MTA Fillapex and Endo CPM. In (D), MTA Fillapex and Endo CPM showed less radio-opacity than aluminium. For all of the materials, the radio-opacity was higher in (S) than in (D). Compared with dentin, all of the materials were more radio-opaque. Conclusions: The comparison of the two assessment methods for sealer radio-opacity testing validated the use of a tissue simulator block. PMID:25651275

  8. Advances in lens implant technology

    PubMed Central

    Kampik, Anselm; Dexl, Alois K.; Zimmermann, Nicole; Glasser, Adrian; Baumeister, Martin; Kohnen, Thomas

    2013-01-01

    Cataract surgery is one of the oldest and the most frequent outpatient clinic operations in medicine performed worldwide. The clouded human crystalline lens is replaced by an artificial intraocular lens implanted into the capsular bag. During the last six decades, cataract surgery has undergone rapid development from a traumatic, manual surgical procedure with implantation of a simple lens to a minimally invasive intervention increasingly assisted by high technology and a broad variety of implants customized for each patient’s individual requirements. This review discusses the major advances in this field and focuses on the main challenge remaining – the treatment of presbyopia. The demand for correction of presbyopia is increasing, reflecting the global growth of the ageing population. Pearls and pitfalls of currently applied methods to correct presbyopia and different approaches under investigation, both in lens implant technology and in surgical technology, are discussed. PMID:23413369

  9. Cholesterol Bilayer Domains in the Eye Lens Health: A Review.

    PubMed

    Widomska, Justyna; Subczynski, Witold K; Mainali, Laxman; Raguz, Marija

    2017-12-01

    The most unique biochemical characteristic of the eye lens fiber cell plasma membrane is its extremely high cholesterol content, the need for which is still unclear. It is evident, however, that the disturbance of Chol homeostasis may result in damages associated with cataracts. Electron paramagnetic resonance methods allow discrimination of two types of lipid domains in model membranes overloaded with Chol, namely, phospholipid-cholesterol domains and pure Chol bilayer domains. These domains are also detected in human lens lipid membranes prepared from the total lipids extracted from lens cortices and nuclei of donors from different age groups. Independent of the age-related changes in phospholipid composition, the physical properties of phospholipid-Chol domains remain the same for all age groups and are practically identical for cortical and nuclear membranes. The presence of Chol bilayer domains in these membranes provides a buffering capacity for cholesterol concentration in the surrounding phospholipid-Chol domains, keeping it at a constant saturating level and thus keeping the physical properties of the membrane consistent with and independent of changes in phospholipid composition. It seems that the presence of Chol bilayer domains plays an integral role in the regulation of cholesterol-dependent processes in fiber cell plasm membranes and in the maintenance of fiber cell membrane homeostasis.

  10. A Novel Technique to Calculate UV Opacity at Gale Crater from MSL/REMS Measurements

    NASA Astrophysics Data System (ADS)

    Vicente-Retortillo, Álvaro; Martínez, Germán M.; Renno, Nilton O.; Lemmon, Mark T.; Mason, Emily L.; de la Torre-Juárez, Manuel

    2016-04-01

    The Rover Environmental Monitoring Station (REMS) on board the Mars Science Laboratory (MSL) mission carries a UV sensor that for the first time is measuring the solar radiation at the surface of Mars in six bands between 200 and 380 nm [1]. Here we present a novel methodology to calculate the atmospheric opacity by using the UV photodiode output currents measured by this sensor (TELRDR products) and ancillary (ADR) data. We estimate the diffuse and total radiation signals by analyzing the events in which the direct solar beam was temporarily blocked by the masthead or by the mast of the rover. Then we use a radiative transfer model with updated radiative properties of the Martian aerosols ([2], [3]) based on the Monte-Carlo method to retrieve the UV opacity from those measurements. Therefore, this methodology is not sensitive to the degradation of the sensor due to the deposition of dust on it. In addition, by using TELRDR and ADR data, inconsistencies in the processed reduced data (ENVRDR and MODRDR products, in units of W/m2) found when the solar zenith angle relative to REMS rover frame is above 30° are avoided. In order to validate our technique, we compare the UV opacities with those derived from Mastcam observations at 880 nm. We find that both opacities show a good agreement and follow a similar seasonal trend, with the UV opacity showing values generally lower than at 880 nm. The difference between both opacities varies over the year, with the minimum difference occurring during the first half of the winter, when both opacities show their annual lowest values. The temporal variation of this difference may be used to analyze changes in the dust size distribution. [1] Gómez-Elvira, J., Armiens, C., Castañer, L., Domínguez, M., Genzer, M. et al. REMS: the environmental sensor suite for the Mars Science Laboratory rover. Space Sci. Rev., 170 (1-4), 583-640, 2012. [2] Vicente-Retortillo, A., Valero, F., Vázquez, L. and Martínez, G. M. A model to calculate

  11. Crystalline lens and refractive development.

    PubMed

    Iribarren, Rafael

    2015-07-01

    Individual refractive errors usually change along lifespan. Most children are hyperopic in early life. This hyperopia is usually lost during growth years, leading to emmetropia in adults, but myopia also develops in children during school years or during early adult life. Those subjects who remain emmetropic are prone to have hyperopic shifts in middle life. And even later, at older ages, myopic shifts are developed with nuclear cataract. The eye grows from 15 mm in premature newborns to approximately 24 mm in early adult years, but, in most cases, refractions are maintained stable in a clustered distribution. This growth in axial length would represent a refractive change of more than 40 diopters, which is compensated by changes in corneal and lens powers. The process which maintains the balance between the ocular components of refraction during growth is still under study. As the lens power cannot be measured in vivo, but can only be calculated based on the other ocular components, there have not been many studies of lens power in humans. Yet, recent studies have confirmed that the lens loses power during growth in children, and that hyperopic and myopic shifts in adulthood may be also produced by changes in the lens. These studies in children and adults give a picture of the changing power of the lens along lifespan. Other recent studies about the growth of the lens and the complexity of its internal structure give clues about how these changes in lens power are produced along life. Copyright © 2015 Elsevier Ltd. All rights reserved.

  12. Research on Spectroscopy, Opacity, and Atmospheres

    NASA Technical Reports Server (NTRS)

    Kurucz, Robert L.

    1999-01-01

    A web site has been set up to make the calculations accessible; (i.e., cfakus.harvard.edu) This data can also be accessed by FTP. It has all of the atomic and diatomic molecular data, tables of distribution function opacities, grids of model atmospheres, colors, fluxes, etc, programs that are ready for distribution, and most of recent papers developed during this grant. Atlases and computed spectra will be added as they are completed. New atomic and molecular calculations will be added as they are completed. The atomic programs that had been running on a Cray at the San Diego Supercomputer Center can now run on the Vaxes and Alpha. The work started with Ni and Co because there were new laboratory analyses that included isotopic and hyperfine splitting. Those calculations are described in the appended abstract for the 6th Atomic Spectroscopy and oscillator Strengths meeting in Victoria last summer. A surprising finding is that quadrupole transitions have been grossly in error because mixing with higher levels has not been included. All levels up through n=9 for Fe I and II, the spectra for which the most information is available, are now included. After Fe I and Fe II, all other spectra are "easy". ATLAS12, the opacity sampling program for computing models with arbitrary abundances, has been put on the web server. A new distribution function opacity program for workstations that replaces the one used on the Cray at the San Diego Supercomputer Center has been written. Each set of abundances would take 100 Cray hours costing $100,000.

  13. Pigmented striae of the anterior lens capsule and age-associated pigment dispersion of variable degree in a group of older African-Americans: an age, race, and gender matched study.

    PubMed

    Roberts, D K; Winters, J E; Castells, D D; Clark, C A; Teitelbaum, B A

    2001-01-01

    To investigate pigmented striae of the anterior lens capsule in African-Americans, a potential indicator of significant anterior segment pigment dispersion. A group of 40 African-American subjects who exhibited pigmented lens striae (PLS) were identified from a non-referred, primary eye care population in Chicago, IL, USA. These subjects were then compared to an age, race, and gender matched control group relative to refractive error and the presence or absence of diabetes and hypertension. The PLS subjects (mean age = 65.4 +/- 8.8 years, range = 50-87 years) consisted of 36 females and 4 males. PLS were bilateral in 36 (85%) of the 40 subjects. Among the eyes with PLS, 21 (55%) of 38 right eyes and 22 (61%) of 36 left eyes also had significant corneal endothelial pigment dusting, commonly in the shape of a Krukenberg's spindle. Ten (25%) of the PLS subjects had either glaucoma or ocular hypertension (7 bilateral, 3 unilateral). The presence of trabecular meshwork pigment varied from minimal to heavy. The mean +/- SD (range) refractive error of the PLS right eyes was +1.61 +/- 1.43D (-1.50 to +5.00D) and +1.77 +/- 1.37D (-1.00 to +5.00D) for the left eyes. Based on these data, the PLS right eyes were +1.63D (Student's t, p = 0.0001; 95% CI = +0.82 to +2.44D) more hyperopic on average than the control right eyes, and the PLS left eyes were +1.77D (p = 0.0001; 95% CI = +0.92 to +2.63D) more hyperopic on average than the control left eyes. Trend analysis showed a gradually increasing likelihood of PLS with increasing magnitude of hyperopia in both eyes (Mantel-Haenszel chi-square, p = 0.001). Among PLS subjects, 24 (60%) of 40 were hypertensive and 9 (23%) of 40 were diabetic. However, these proportions were not significantly different (two-tailed Fisher's exact test; hypertension: p = 0.30; diabetes: p = 0.70) from the randomly selected controls. Among our African-American group, which consisted predominately of females >50 years of age, the likelihood of PLS

  14. Calculation of crystalline lens power in chickens with a customized version of Bennett's equation.

    PubMed

    Iribarren, Rafael; Rozema, Jos J; Schaeffel, Frank; Morgan, Ian G

    2014-03-01

    This paper customizes Bennett's equation for calculating lens power in chicken eyes from refraction, keratometry and biometry. Previously published data on refraction, corneal power, anterior chamber depth, lens thickness, lens radii of curvature, axial length and eye power in chickens aged 10-90 days were used to estimate Gullstrand's lens power and Bennett's lens power for chicken eyes, and to calculate the lens equivalent refractive index. Bennett's A and B constants for the front and back surface powers of the lens were calculated for data measured from day 10 to 90 at 10 day intervals, and mean customized constants were calculated. The mean customized constants for Bennett's equation for chicks were A=0.574±0.023 and B=0.379±0.021. As found previously, lens power decreases with age in chicks, while corneal power decreases and axial length increases. The lens equivalent refractive index decreases with age from 10 to 90 days after hatching. Bennett's equation can be used to calculate lens power in chicken eyes for studies on animal myopia, using standard biometry. Copyright © 2014 Elsevier B.V. All rights reserved.

  15. Effective Tree Scattering and Opacity at L-Band

    NASA Technical Reports Server (NTRS)

    Kurum, Mehmet; O'Neill, Peggy E.; Lang, Roger H.; Joseph, Alicia T.; Cosh, Michael H.; Jackson, Thomas J.

    2011-01-01

    This paper investigates vegetation effects at L-band by using a first-order radiative transfer (RT) model and truck-based microwave measurements over natural conifer stands to assess the applicability of the tau-omega) model over trees. The tau-omega model is a zero-order RT solution that accounts for vegetation effects with effective vegetation parameters (vegetation opacity and single-scattering albedo), which represent the canopy as a whole. This approach inherently ignores multiple-scattering effects and, therefore, has a limited validity depending on the level of scattering within the canopy. The fact that the scattering from large forest components such as branches and trunks is significant at L-band requires that zero-order vegetation parameters be evaluated (compared) along with their theoretical definitions to provide a better understanding of these parameters in the retrieval algorithms as applied to trees. This paper compares the effective vegetation opacities, computed from multi-angular pine tree brightness temperature data, against the results of two independent approaches that provide theoretical and measured optical depths. These two techniques are based on forward scattering theory and radar corner reflector measurements, respectively. The results indicate that the effective vegetation opacity values are smaller than but of similar magnitude to both radar and theoretical estimates. The effective opacity of the zero-order model is thus set equal to the theoretical opacity and an explicit expression for the effective albedo is then obtained from the zero- and first- order RT model comparison. The resultant albedo is found to have a similar magnitude as the effective albedo value obtained from brightness temperature measurements. However, it is less than half of that estimated using the theoretical calculations (0.5 - 0.6 for tree canopies at L-band). This lower observed albedo balances the scattering darkening effect of the large theoretical albedo

  16. Palm is expressed in both developing and adult mouse lens and retina

    PubMed Central

    Castellini, Meryl; Wolf, Louise V; Chauhan, Bharesh K; Galileo, Deni S; Kilimann, Manfred W; Cvekl, Ales; Duncan, Melinda K

    2005-01-01

    Background Paralemmin (Palm) is a prenyl-palmitoyl anchored membrane protein that can drive membrane and process formation in neurons. Earlier studies have shown brain preferred Palm expression, although this protein is a major water insoluble protein in chicken lens fiber cells and the Palm gene may be regulated by Pax6. Methods The expression profile of Palm protein in the embryonic, newborn and adult mouse eye as well as dissociated retinal neurons was determined by confocal immunofluorescence. The relative mRNA levels of Palm, Palmdelphin (PalmD) and paralemmin2 (Palm2) in the lens and retina were determined by real time rt-PCR. Results In the lens, Palm is already expressed at 9.5 dpc in the lens placode, and this expression is maintained in the lens vesicle throughout the formation of the adult lens. Palm is largely absent from the optic vesicle but is detectable at 10.5 dpc in the optic cup. In the developing retina, Palm expression transiently upregulates during the formation of optic nerve as well as in the formation of both the inner and outer plexiform layers. In short term dissociated chick retinal cultures, Palm protein is easily detectable, but the levels appear to reduce sharply as the cultures age. Palm mRNA was found at much higher levels relative to Palm2 or PalmD in both the retina and lens. Conclusion Palm is the major paralemmin family member expressed in the retina and lens and its expression in the retina transiently upregulates during active neurite outgrowth. The expression pattern of Palm in the eye is consistent with it being a Pax6 responsive gene. Since Palm is known to be able to drive membrane formation in brain neurons, it is possible that this molecule is crucial for the increase in membrane formation during lens fiber cell differentiation. PMID:15969763

  17. Macular pigment density variation after supplementation of lutein and zeaxanthin using the Visucam® 200 pigment module: Impact of age-related macular degeneration and lens status.

    PubMed

    Azar, G; Quaranta-El Maftouhi, M; Masella, J-J; Mauget-Faÿsse, M

    2017-04-01

    To assess the evolution of macular pigment optical density (MPOD) following supplementation with various macular formulations obtained with the Visucam ® 200, and to study the factors affecting MPOD measurements. In this prospective, randomized, double-masked multicenter study, patients were divided into 2 groups: group A (patients without retinal pathology who underwent cataract surgery 1 month previously) and group B (patients with neovascular age-related macular degeneration [AMD] in one eye). In each group, half of the patients were randomly assigned to receive a food supplementation either with or without carotenoids (5mg of Lutein and 1mg of Zeaxanthin). Outcome measures included MPOD responses obtained with the Visucam ® 200 for one year. In total, 126 subjects (52 men, 74 women) with a mean age of 75.3±7.61 years were enrolled. Mean MPOD values at the time of inclusion were statistically lower in group A (0.088 density unit [DU]) compared to group B (0.163 DU, P<0.05). No statistically significant increase in MPOD was noted in either group, even after discontinuation of the supplementation. By multiple regression analysis, age, female gender, lens status and the presence of AMD seemed to significantly affect MPOD measurements. No significant improvement in MPOD seems to be detected with the Visucam ® 200 after carotenoid supplementation. The MPOD measurement seems to be highly affected by cataract extraction and the presence of AMD. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  18. Massive formation of square array junctions dramatically alters cell shape but does not cause lens opacity in the cav1-KO mice.

    PubMed

    Biswas, Sondip K; Brako, Lawrence; Lo, Woo-Kuen

    2014-08-01

    The wavy square array junctions are composed of truncated aquaporin-0 (AQP0) proteins typically distributed in the deep cortical and nuclear fibers in wild-type lenses. These junctions may help maintain the narrowed extracellular spaces between fiber cells to minimize light scattering. Herein, we investigate the impact of the cell shape changes, due to abnormal formation of extensive square array junctions, on the lens opacification in the caveolin-1 knockout mice. The cav1-KO and wild-type mice at age 1-22 months were used. By light microscopy examinations, cav1-KO lenses at age 1-18 months were transparent in both cortical and nuclear regions, whereas some lenses older than 18 months old exhibited nuclear cataracts. Scanning EM consistently observed the massive formation of ridge-and-valley membrane surfaces in young fibers at approximately 150 μm deep in all cav1-KO lenses studied. In contrast, the typical ridge-and-valleys were only seen in mature fibers deeper than 400 μm in wild-type lenses. The resulting extensive ridge-and-valleys dramatically altered the overall cell shape in cav1-KO lenses. Remarkably, despite dramatic shape changes, these deformed fiber cells remained intact and made close contact with their neighboring cells. By freeze-fracture TEM, ridge-and-valleys exhibited the typical orthogonal arrangement of 6.6 nm square array intramembrane particles and displayed the narrowed extracellular spaces. Immunofluorescence analysis showed that AQP0 C-terminus labeling was significantly decreased in outer cortical fibers in cav1-KO lenses. However, freeze-fracture immunogold labeling showed that the AQP0 C-terminus antibody was sparsely distributed on the wavy square array junctions, suggesting that the cleavage of AQP0 C-termini might not yet be complete. The cav1-KO lenses with nuclear cataracts showed complete cellular breakdown and large globule formation in the lens nucleus. This study suggests that despite dramatic cell shape changes, the

  19. Ultrashort-Pulse Lasers Treating the Crystalline Lens: Will They Cause Vision-Threatening Cataract? (An American Ophthalmological Society Thesis)

    PubMed Central

    Krueger, Ronald R.; Uy, Harvey; McDonald, Jared; Edwards, Keith

    2012-01-01

    Purpose: To demonstrate that ultrashort-pulse laser treatment in the crystalline lens does not form a focal, progressive, or vision-threatening cataract. Methods: An Nd:vanadate picosecond laser (10 ps) with prototype delivery system was used. Primates: 11 rhesus monkey eyes were prospectively treated at the University of Wisconsin (energy 25–45 μJ/pulse and 2.0–11.3M pulses per lens). Analysis of lens clarity and fundus imaging was assessed postoperatively for up to 4½ years (5 eyes). Humans: 80 presbyopic patients were prospectively treated in one eye at the Asian Eye Institute in the Philippines (energy 10 μJ/pulse and 0.45–1.45M pulses per lens). Analysis of lens clarity, best-corrected visual acuity, and subjective symptoms was performed at 1 month, prior to elective lens extraction. Results: Bubbles were immediately seen, with resolution within the first 24 to 48 hours. Afterwards, the laser pattern could be seen with faint, noncoalescing, pinpoint micro-opacities in both primate and human eyes. In primates, long-term follow-up at 4½ years showed no focal or progressive cataract, except in 2 eyes with preexisting cataract. In humans, <25% of patients with central sparing (0.75 and 1.0 mm radius) lost 2 or more lines of best spectacle-corrected visual acuity at 1 month, and >70% reported acceptable or better distance vision and no or mild symptoms. Meanwhile, >70% without sparing (0 and 0.5 mm radius) lost 2 or more lines, and most reported poor or severe vision and symptoms. Conclusions: Focal, progressive, and vision-threatening cataracts can be avoided by lowering the laser energy, avoiding prior cataract, and sparing the center of the lens. PMID:23818739

  20. Semiautomated analysis of optical coherence tomography crystalline lens images under simulated accommodation

    PubMed Central

    Kim, Eon; Ehrmann, Klaus; Uhlhorn, Stephen; Borja, David; Arrieta-Quintero, Esdras; Parel, Jean-Marie

    2011-01-01

    Presbyopia is an age related, gradual loss of accommodation, mainly due to changes in the crystalline lens. As part of research efforts to understand and cure this condition, ex vivo, cross-sectional optical coherence tomography images of crystalline lenses were obtained by using the Ex-Vivo Accommodation Simulator (EVAS II) instrument and analyzed to extract their physical and optical properties. Various filters and edge detection methods were applied to isolate the edge contour. An ellipse is fitted to the lens outline to obtain central reference point for transforming the pixel data into the analysis coordinate system. This allows for the fitting of a high order equation to obtain a mathematical description of the edge contour, which obeys constraints of continuity as well as zero to infinite surface slopes from apex to equator. Geometrical parameters of the lens were determined for the lens images captured at different accommodative states. Various curve fitting functions were developed to mathematically describe the anterior and posterior surfaces of the lens. Their differences were evaluated and their suitability for extracting optical performance of the lens was assessed. The robustness of these algorithms was tested by analyzing the same images repeated times. PMID:21639571

  1. Semiautomated analysis of optical coherence tomography crystalline lens images under simulated accommodation.

    PubMed

    Kim, Eon; Ehrmann, Klaus; Uhlhorn, Stephen; Borja, David; Arrieta-Quintero, Esdras; Parel, Jean-Marie

    2011-05-01

    Presbyopia is an age related, gradual loss of accommodation, mainly due to changes in the crystalline lens. As part of research efforts to understand and cure this condition, ex vivo, cross-sectional optical coherence tomography images of crystalline lenses were obtained by using the Ex-Vivo Accommodation Simulator (EVAS II) instrument and analyzed to extract their physical and optical properties. Various filters and edge detection methods were applied to isolate the edge contour. An ellipse is fitted to the lens outline to obtain central reference point for transforming the pixel data into the analysis coordinate system. This allows for the fitting of a high order equation to obtain a mathematical description of the edge contour, which obeys constraints of continuity as well as zero to infinite surface slopes from apex to equator. Geometrical parameters of the lens were determined for the lens images captured at different accommodative states. Various curve fitting functions were developed to mathematically describe the anterior and posterior surfaces of the lens. Their differences were evaluated and their suitability for extracting optical performance of the lens was assessed. The robustness of these algorithms was tested by analyzing the same images repeated times.

  2. Fac-Back-OPAC: An Open Source Interface to Your Library System

    ERIC Educational Resources Information Center

    Beccaria, Mike; Scott, Dan

    2007-01-01

    The new Fac-Back-OPAC (a faceted backup OPAC) is built on code that was originally developed by Casey Durfee in February 2007. It represents the convergence of two prominent trends in library tools: the decoupling of discovery tools from the traditional integrated library system (ILS) and the use of readily available open source components to…

  3. The effect of successful contact lens wear on mucosal immunity of the eye.

    PubMed

    McClellan, K A; Cripps, A W; Clancy, R L; Billson, F A

    1998-08-01

    This study aimed to assess the effect of contact lens wear on the mucosal defenses of the outer eye against infection. A case-controlled study of daily contact lens wearers in their initial 6 months of contact lens wear. Contact lens wearers (mean age, 23.1 years; 47 subjects) were compared with age-matched control subjects (mean age, 24.7 years; 44 subjects). Outer eye defenses were studied by assay of tear constituents and quantitative conjunctival microbiology. Antimicrobial activity of tears was studied by assay of total immunoglobulin A (IgA), IgA isotype-specific antibodies reactive with Escherichia coli, Haemophilus influenzae, Staphylococcus epidermidis, albumin and lysozyme, and the ocular surface microbial load determined using quantitative microbiology of the conjunctival sac. The IgA isotype-specific antibodies reactive with E. coli (P = 0.03) and S. epidermidis (P = 0.068) were lower in contact lens wearers, but antibody:albumin ratios were not significantly different in the two groups. Contact lens wear also had no significant effect on tear IgA, albumin, or lysozyme or its ratios with albumin. Bacterial numbers and colonization rates for coagulase-negative staphylococci were greater in contact lens wearers than in age-matched control subjects. Corynebacterium sp. and non-Enterobacteriaceae (P = 0.007) were isolated more frequently and in greater numbers from contact lens wearers. Colonization rates were increased for Corynebacterium sp., but non-Enterobacteriaceae were transient. In both daily contact lens wearers and age-matched control subjects, most conjunctival flora were transient rather than colonizing, and no subject developed an outer eye infection during the study. These results suggest that daily contact lens wear does not significantly alter the mucosal defenses of the outer eye that function to eliminate organisms from the conjunctival sac and prevent outer eye infection.

  4. Cat-Map: putting cataract on the map

    PubMed Central

    Bennett, Thomas M.; Hejtmancik, J. Fielding

    2010-01-01

    Lens opacities, or cataract(s), may be inherited as a classic Mendelian disorder usually with early-onset or, more commonly, acquired with age as a multi-factorial or complex trait. Many genetic forms of cataract have been described in mice and other animal models. Considerable progress has been made in mapping and identifying the genes and mutations responsible for inherited forms of cataract, and genetic determinants of age-related cataract are beginning to be discovered. To provide a convenient and accurate summary of current information focused on the increasing genetic complexity of Mendelian and age-related cataract we have created an online chromosome map and reference database for cataract in humans and mice (Cat-Map). PMID:21042563

  5. Primate lens capsule elasticity assessed using Atomic Force Microscopy

    PubMed Central

    Ziebarth, Noël M.; Arrieta, Esdras; Feuer, William J.; Moy, Vincent T.; Manns, Fabrice; Parel, Jean-Marie

    2011-01-01

    The purpose of this project is to measure the elasticity of the human and non-human primate lens capsule at the microscopic scale using Atomic Force Microscopy (AFM). Elasticity measurements were performed using AFM on the excised anterior lens capsule from 9 cynomolgus monkey (5.9–8.0 years), 8 hamadryas baboon (2.8–10.1 years), and 18 human lenses (33–79 years). Anterior capsule specimens were obtained by performing a 5mm continuous curvilinear capsulorhexis and collecting the resulting disk of capsular tissue. To remove the lens epithelial cells the specimen was soaked in 0.1% trypsin and 0.02% EDTA for five minutes, washed, and placed on a Petri dish and immersed in DMEM. Elasticity measurements of the capsule were performed with a laboratory-built AFM system custom designed for force measurements of ophthalmic tissues. The capsular specimens were probed with an AFM cantilever tip to produce force-indentation curves for each specimen. Young’s modulus was calculated from the force-indentation curves using the model of Sneddon for a conical indenter. Young’s modulus of elasticity was 20.1–131kPa for the human lens capsule, 9.19–117kPa for the cynomolgus lens capsule, and 13.1–62.4kPa for the baboon lens capsule. Young’s modulus increased significantly with age in humans (p=0.03). The age range of the monkey and baboon samples was not sufficient to justify an analysis of age dependence. The capsule elasticity of young humans (<45 years) was not statistically different from that of the monkey and baboon. In humans, there is an increase in lens capsule stiffness at the microscale that could be responsible for an increase in lens capsule bulk stiffness. PMID:21420953

  6. Compound lens

    DOEpatents

    Brixner, B.B.; Klein, M.M.; Winkler, M.A.

    1980-05-21

    The disclosure relates to at least one calcium fluoride optical element used in combination with at least two ordinary crown glass lens elements to greatly reduce secondary spectrum in optical systems.

  7. Compound lens

    DOEpatents

    Brixner, Berlyn B.; Klein, Morris M.; Winkler, Max A.

    1982-01-01

    The disclosure relates to at least one calcium fluoride optical element used in combination with at least two ordinary crown glass lens elements to greatly reduce secondary spectrum in optical systems.

  8. Does infrared or ultraviolet light damage the lens?

    PubMed Central

    Söderberg, P G; Talebizadeh, N; Yu, Z; Galichanin, K

    2016-01-01

    In daylight, the human eye is exposed to long wavelength ultraviolet radiation (UVR), visible radiation and short wavelength infrared radiation (IRR). Almost all the UVR and a fraction of the IRR waveband, respectively, left over after attenuation in the cornea, is absorbed in the lens. The time delay between exposure and onset of biological response in the lens varies from immediate-to-short-to-late. After exposure to sunlight or artificial sources, generating irradiances of the same order of magnitude or slightly higher, biological damage may occur photochemically or thermally. Epidemiological studies suggest a dose-dependent association between short wavelength UVR and cortical cataract. Experimental data infer that repeated daily in vivo exposures to short wavelength UVR generate photochemically induced damage in the lens, and that short delay onset cataract after UVR exposure is photochemically induced. Epidemiology suggests that daily high-intensity short wavelength IRR exposure of workers, is associated with a higher prevalence of age-related cataract. It cannot be excluded that this effect is owing to a thermally induced higher denaturation rate. Recent experimental data rule out a photochemical effect of 1090 nm in the lens but other wavelengths in the near IRR should be investigated. PMID:26768915

  9. Tear analysis in contact lens wearers.

    PubMed Central

    Farris, R L

    1985-01-01

    Tear analysis in contact lens wearers was compared with tear analysis in aphakics without contact lens wear and normal phakic patients. Subjects were divided into five groups: group 1, aphakic without contact lens; group 2, phakic with daily-wear hard contact lens; group 3, phakic with daily-wear soft contact lens; group 4, phakic with extended-wear soft contact lens; and group 5, aphakic with extended-wear soft contact lens. The experimental groups were compared with age- and sex-matched control groups for statistical analysis of tear variables by means of the Student's t-test. The variables measured were tear osmolarity, tear albumin, and lysozyme and lactoferrin concentrations in basal and reflex tears. Highly significant elevations of tear osmolarity were found in aphakic subjects without contact lenses. Less significant differences in tear osmolarity were found in phakic subjects with hard daily-wear lenses or with extended-wear soft lenses. Tear albumin, lysozyme, and lactoferrin in basal and reflex tears were not significantly different in the different groups of contact lens wearers or in the group of aphakic subjects without contact lenses compared with their control groups. Individual variations in tear albumin, lysozyme, and lactoferrin appeared to be responsible for the inability to demonstrate significant differences in tear composition in association with the wearing of different types of contact lenses. Older and aphakic patients demonstrated a tendency to have increased concentrations of proteins in the tears compared with younger, phakic contact lens wearers and normal controls without contact lenses. PMID:3914131

  10. Galactic cold cores. VI. Dust opacity spectral index

    NASA Astrophysics Data System (ADS)

    Juvela, M.; Demyk, K.; Doi, Y.; Hughes, A.; Lefèvre, C.; Marshall, D. J.; Meny, C.; Montillaud, J.; Pagani, L.; Paradis, D.; Ristorcelli, I.; Malinen, J.; Montier, L. A.; Paladini, R.; Pelkonen, V.-M.; Rivera-Ingraham, A.

    2015-12-01

    Context. The Galactic Cold Cores project has carried out Herschel photometric observations of 116 fields where the Planck survey has found signs of cold dust emission. The fields contain sources in different environments and different phases of star formation. Previous studies have revealed variations in their dust submillimetre opacity. Aims: The aim is to measure the value of dust opacity spectral index and to understand its variations spatially and with respect to other parameters, such as temperature, column density, and Galactic location. Methods: The dust opacity spectral index β and the dust colour temperature T are derived using Herschel and Planck data. The relation between β and T is examined for the whole sample and inside individual fields. Results: Based on IRAS and Planck data, the fields are characterised by a median colour temperature of 16.1 K and a median opacity spectral index of β = 1.84. The values are not correlated with Galactic longitude. We observe a clear T-β anti-correlation. In Herschel observations, constrained at lower resolution by Planck data, the variations follow the column density structure and βFIR can rise to ~2.2 in individual clumps. The highest values are found in starless clumps. The Planck 217 GHz band shows a systematic excess that is not restricted to cold clumps and is thus consistent with a general flattening of the dust emission spectrum at millimetre wavelengths. When fitted separately below and above 700 μm, the median spectral index values are βFIR ~ 1.91 and β(mm) ~ 1.66. Conclusions: The spectral index changes as a function of column density and wavelength. The comparison of different data sets and the examination of possible error sources show that our results are robust. However, β variations are partly masked by temperature gradients and the changes in the intrinsic grain properties may be even greater. Planck http://www.esa.int/Planck is a project of the European Space Agency - ESA - with instruments

  11. Ocular surface and tear film status among contact lens wearers and non-wearers who use VDT at work: comparing three different lens types.

    PubMed

    Tauste, Ana; Ronda, Elena; Baste, Valborg; Bråtveit, Magne; Moen, Bente E; Seguí Crespo, María-Del-Mar

    2018-04-01

    To analyze differences in the ocular surface appearance and tear film status of contact lens wearers and non-wearers in a group of visual display terminals (VDT) workers and additionally to assess differences between lens materials. Cross-sectional study of 236 office workers, of whom 92 were contact lens wearers. Workers provided information on their contact lenses (conventional hydrogel, silicone hydrogel or rigid gas permeable lenses) and exposure to VDT at work. Ocular surface and tear film status were determined by the presence of bulbar, limbal and lid redness, lid roughness and corneal staining type, and by Schirmer's and tear break-up time tests (TBUT). A generalized linear model was used to calculate the crude (cRR) and age- and sex-adjusted (aRR) relative risk to measure the association between ocular surface and tear film abnormalities and contact lens use and type. The aRR of ocular surface abnormalities was higher in contact lens wearers compared to non-wearers: bulbar redness (aRR 1.69; 95% CI 1.25-2.30), limbal redness (aRR 2.87; 1.88-4.37), lid redness (aRR 2.53; 1.35-4.73) and lid roughness (aRR 7.03; 1.31-37.82). VDT exposure > 4 h/day increased wearers' risk of limbal and lid redness. Conventional hydrogel wearers had the highest risk of ocular surface abnormalities, followed by silicone hydrogel wearers. Both contact and non-contact lens wearers had a high prevalence of altered TBUT (77.3 and 75.7% respectively) and Schirmer (51.8 and 41.3%). Regular contact lens use during VDT exposure at work increases risk of bulbar, limbal and lid redness, and lid roughness, especially in soft contact lens wearers. The high prevalence of altered TBUT and Schirmer's results in all participants suggests that VDT use greatly affects tear film characteristics.

  12. Four-year Follow-up of the Changes in Anterior Segment After Phakic Collamer Lens Implantation.

    PubMed

    Lu, Yuanyuan; Yang, Na; Li, Xuedong; Kong, Jun

    2017-06-01

    To assess the changes and relationship in central vaulting, flare intensity, and crystalline lens thickness during a follow-up period of 4 years after implantable collamer lens (ICL) implantation in eyes with high myopia. Retrospective observational study. Ninety-eight eyes of 50 patients were followed up with routine measurements of central vaulting, crystalline lens thickness, endothelial cell density, and aqueous flare postoperatively. Data were analyzed by repeated-measures analysis of variance. The relationship between the annual change in crystal lens thickness after surgery and age was evaluated by Pearson correlation coefficient and linear regression. There was a continuous reduction in central vaulting and endothelial cell density as well as an increase in crystalline lens thickness in ICL eyes from 1 month onward to 5 years postoperatively (P < .001). Although the trend of variation during the individual visit period was accentuated, the variation turned out to be smaller between 12 and 36 months or 60 months postoperatively (P = .42, P = .65). Aqueous flare intensity increased significantly after surgery and returned to normal 1 year later. Additionally, a positive correlation between patient age and crystalline lens thickness (r = 0.617, P < .0001) was observed in eyes with ICL implantation. The changes in central vaulting, endothelial cell density, and crystalline lens thickness are more prominent during the first year after ICL implantation, tending to be relatively stable afterwards. The anterior inflammation during the early postoperative period synchronizes with the sharp progression of crystalline lens changes within the first year. Copyright © 2017 Elsevier Inc. All rights reserved.

  13. Target simulations with SCROLL non-LTE opacity/emissivity databases.

    NASA Astrophysics Data System (ADS)

    Klapisch, M.; Colombant, D.; Bar-Shalom, A.

    2001-10-01

    SCROLL[1], a collisional radiative model and code based on superconfigurations, is able to compute high Z non-LTE opacities and emissivities accurately and efficiently. It was used to create opacity/emissivity databases for Pd, Lu, Au on a 50 temperatures/80 densities grid. Incident radiation field was shown to have no effect on opacities in the case of interest, and was not taken into account. These databases were introduced in the hydrocode FAST1D[2]. SCROLL also gives an ionization temperature Tz which is used in FAST1D to obtain non-LTE corrections to the equation of state. Results will be compared to those of a previous version using Busquet’s algorithm[3]. Work supported by USDOE under a contract with NRL. [1] A. Bar-Shalom, J. Oreg and M. Klapisch, J. Quant. Spectrosc. Radiat. Transfer, 65, 43(2000). [2] J. H. Gardner, A. J. Schmitt, J. P. Dahlburg, C. J. Pawley, S. E. Bodner, S. P. Obenschain, V. Serlin and Y. Aglitskiy, Phys. Plasmas, 5, 1935 (1998). [3] M. Busquet, Phys. Fluids B, 5, 4191 (1993).

  14. Momentum deposition on Wolf-Rayet winds: Nonisotropic diffusion with effective gray opacity

    NASA Technical Reports Server (NTRS)

    Gayley, Kenneth G.; Owocki, Stanley P.; Cranmer, Steven R.

    1995-01-01

    We derive the velocity and mass-loss rate of a steady state Wolf-Rayet (WR) wind, using a nonisotropic diffusion approximation applied to the transfer between strongly overlapping spectral lines. Following the approach of Friend & Castor (1983), the line list is assumed to approximate a statistically parameterized Poisson distribution in frequency, so that photon transport is controlled by an angle-dependent, effectively gray opacity. We show the nonisotropic diffusion approximation yields good agreement with more accurate numerical treatments of the radiative transfer, while providing analytic insight into wind driving by multiple scattering. We illustrate, in particular, that multiple radiative momentum deposition does not require that potons be repeatedly reflected across substantial distances within the spherical envelope, but indeed is greatest when photons undergo a nearly local diffusion, e.g., through scattering by many lines closely spaced in frequency. Our results reiterate the view that the so-called 'momentum problem' of Wolf-Rayet winds is better characterized as an 'opacity problem' of simply identfying enough lines. One way of increasing the number of thick lines in Wolf-Rayet winds is to transfer opacity from saturated to unsaturated lines, yielding a steeper opacity distribution than that found in OB winds. We discuss the implications of this perspective for extending our approach to W-R wind models that incorporate a more fundamental treatment of the ionization and excitation processes that determine the line opacity. In particular, we argue that developing statistical descriptions of the lines to allow an improved effective opacity for the line ensemble would offer several advantages for deriving such more fundamental W-R wind models.

  15. Momentum deposition on Wolf-Rayet winds: Nonisotropic diffusion with effective gray opacity

    NASA Astrophysics Data System (ADS)

    Gayley, Kenneth G.; Owocki, Stanley P.; Cranmer, Steven R.

    1995-03-01

    We derive the velocity and mass-loss rate of a steady state Wolf-Rayet (WR) wind, using a nonisotropic diffusion approximation applied to the transfer between strongly overlapping spectral lines. Following the approach of Friend & Castor (1983), the line list is assumed to approximate a statistically parameterized Poisson distribution in frequency, so that photon transport is controlled by an angle-dependent, effectively gray opacity. We show the nonisotropic diffusion approximation yields good agreement with more accurate numerical treatments of the radiative transfer, while providing analytic insight into wind driving by multiple scattering. We illustrate, in particular, that multiple radiative momentum deposition does not require that photons be repeatedly reflected across substantial distances within the spherical envelope, but indeed is greatest when photons undergo a nearly local diffusion, e.g., through scattering by many lines closely spaced in frequency. Our results reiterate the view that the so-called 'momentum problem' of Wolf-Rayet winds is better characterized as an 'opacity problem' of simply identifying enough lines. One way of increasing the number of thick lines in Wolf-Rayet winds is to transfer opacity from saturated to unsaturated lines, yielding a steeper opacity distribution than that found in OB winds. We discuss the implications of this perspective for extending our approach to W-R wind models that incorporate a more fundamental treatment of the ionization and excitation processes that determine the line opacity. In particular, we argue that developing statistical descriptions of the lines to allow an improved effective opacity for the line ensemble would offer several advantages for deriving such more fundamental W-R wind models.

  16. Practical protective tools for occupational exposure: 1) double focus spectacles for the aged with highly refracted glass lens 2) remodeled barrier for radiation protection.

    PubMed

    Kurokawa, S; Yabe, S; Takamura, A; Ishizaki, H; Aizawa, S

    2000-11-30

    Two practical protective tools for occupational exposure for neurointerventional radiologists are presented. The first purpose of this study was to investigate the effectiveness of double focus spectacles for the aged with a highly refracted glass lens (special spectacles for the aged) for radiation protection of the crystalline lens of the eye in comparison with other spectacles on the market, based on the measurement of film density which was obtained by exposure of X-ray through those spectacles. As a result of the film densitometry mentioned above, the effectiveness of special spectacles for the aged in radiation protection was nearly equal to the effectiveness of a goggle type shield which is made with a 0.07 mm lead-equivalent plastic lens. The second purpose of this study was to investigate the effectiveness of the protective barrier, which we remodeled for cerebral angiography or neuroendovascular therapy, for radiation exposure, based on the measurement in a simulated study with a head phantom, and on the measurement of radiation exposure in operaters during procedures of clinical cases. In the experimental study radiation exposure in supposed position of the crystalline lens was reduced to about one third and radiation exposure in supposed position of the gonadal glands was reduced to about one seventh, compared to radiation exposure without employing the barrier. The radiation exposure was monitored at the left breast of three radiologists, in 215 cases of cerebral angiography. Employing the barrier in cerebral angiography, average equivalent dose at the left breast measured 1.49mu Sv during 10 min of fluoroscopy. In three kinds of neuroendovascular therapy in 40 cases, radiation exposure in an operator was monitored in the same fashion and the dose was recorded less than the result reported in previous papers in which any protective barrier have not been employed in the procedure (1,2). As a result, the two above mentioned protective tools are

  17. Age-related Cataract in a Randomized Trial of Selenium and Vitamin E in Men: The SELECT Eye Endpoints (SEE) Study

    PubMed Central

    Christen, William G.; Glynn, Robert J.; Gaziano, J. Michael; Darke, Amy K.; Crowley, John J.; Goodman, Phyllis J.; Lippman, Scott M.; Lad, Thomas E.; Bearden, James D.; Goodman, Gary E.; Minasian, Lori M.; Thompson, Ian M.; Blanke, Charles D.; Klein, Eric A.

    2014-01-01

    Importance Observational studies suggest a role for dietary nutrients such as vitamin E and selenium in cataract prevention. However, the results of randomized trials of vitamin E supplements and cataract have been disappointing, and are not yet available for selenium. Objective To test whether long-term supplementation with selenium and vitamin E affects the incidence of cataract in a large cohort of men. Design, Setting, and Participants The SELECT Eye Endpoints (SEE) study was an ancillary study of the SWOG-coordinated Selenium and Vitamin E Cancer Prevention Trial (SELECT), a randomized, placebo-controlled, four arm trial of selenium and vitamin E conducted among 35,533 men aged 50 years and older for African Americans and 55 and older for all other men, at 427 participating sites in the US, Canada, and Puerto Rico. A total of 11,267 SELECT participants from 128 SELECT sites participated in the SEE ancillary study. Intervention Individual supplements of selenium (200 µg/d from L-selenomethionine) and vitamin E (400 IU/d of all rac-α-tocopheryl acetate). Main Outcome Measures Incident cataract, defined as a lens opacity, age-related in origin, responsible for a reduction in best-corrected visual acuity to 20/30 or worse based on self-report confirmed by medical record review, and cataract extraction, defined as the surgical removal of an incident cataract. Results During a mean (SD) of 5.6 (1.2) years of treatment and follow-up, 389 cases of cataract were documented. There were 185 cataracts in the selenium group and 204 in the no selenium group (hazard ratio [HR], 0.91; 95 percent confidence interval [CI], 0.75 to 1.11; P=.37). For vitamin E, there were 197 cases in the treated group and 192 in the placebo group (HR, 1.02; CI, 0.84 to 1.25; P=.81). Similar results were observed for cataract extraction. Conclusions and Relevance These randomized trial data from a large cohort of apparently healthy men indicate that long-term daily supplementation with selenium

  18. Time Patterns in Remote OPAC Use.

    ERIC Educational Resources Information Center

    Lucas, Thomas A.

    1993-01-01

    Describes a transaction log analysis of the New York Public Library research libraries' OPAC (online public access catalog). Much of the remote searching occurred when the libraries were closed and was more evenly distributed than internal searching, demonstrating that remote searching could expand access and reduce peak system loads. (Contains…

  19. The effect of Livermore OPAL opacities on the evolutionary masses of RR Lyrae stars

    NASA Technical Reports Server (NTRS)

    Yi, Sukyoung; Lee, Young-Wook; Demarque, Pierre

    1993-01-01

    We have investigated the effect of the new Livermore OPAL opacities on the evolution of horizontal-branch (HB) stars. This work was motivated by the recent stellar pulsation calculations using the new Livermore opacities, which suggest that the masses of double-mode RR Lyrae stars are 0.1-0.2 solar mass larger than those based on earlier opacities. Unlike the pulsation calculations, we find that the effect of opacity change on the evolution of HB stars is not significant. In particular, the effect of the mean masses of RR Lyrae stars is very small, showing a decrease of only 0.01-0.02 solar mass compared to the models based on old Cox-Stewart opacities. Consequently, with the new Livermore OPAL opacities, both the stellar pulsation and evolution models now predict approximately the same masses for the RR Lyrae stars. Our evolutionary models suggest that the mean masses of the RR Lyrae stars are about 0.76 and about 0.71 solar mass for M15 (Oosterhoff group II) and M3 (group I), respectively. If (alpha/Fe) = 0.4, these values are decreased by about 0.03 solar mass. Variations of the mean masses of RR Lyrae stars with HB morphology and metallicity are also presented.

  20. Light Scattering by Fractal Dust Aggregates. II. Opacity and Asymmetry Parameter

    NASA Astrophysics Data System (ADS)

    Tazaki, Ryo; Tanaka, Hidekazu

    2018-06-01

    Optical properties of dust aggregates are important at various astrophysical environments. To find a reliable approximation method for optical properties of dust aggregates, we calculate the opacity and the asymmetry parameter of dust aggregates by using a rigorous numerical method, the T-Matrix Method, and then the results are compared to those obtained by approximate methods: the Rayleigh–Gans–Debye (RGD) theory, the effective medium theory (EMT), and the distribution of hollow spheres method (DHS). First of all, we confirm that the RGD theory breaks down when multiple scattering is important. In addition, we find that both EMT and DHS fail to reproduce the optical properties of dust aggregates with fractal dimensions of 2 when the incident wavelength is shorter than the aggregate radius. In order to solve these problems, we test the mean field theory (MFT), where multiple scattering can be taken into account. We show that the extinction opacity of dust aggregates can be well reproduced by MFT. However, it is also shown that MFT is not able to reproduce the scattering and absorption opacities when multiple scattering is important. We successfully resolve this weak point of MFT, by newly developing a modified mean field theory (MMF). Hence, we conclude that MMF can be a useful tool to investigate radiative transfer properties of various astrophysical environments. We also point out an enhancement of the absorption opacity of dust aggregates in the Rayleigh domain, which would be important to explain the large millimeter-wave opacity inferred from observations of protoplanetary disks.

  1. Impact of crystalline lens opacification on effective phacoemulsification time in femtosecond laser-assisted cataract surgery.

    PubMed

    Mayer, Wolfgang J; Klaproth, Oliver K; Hengerer, Fritz H; Kohnen, Thomas

    2014-02-01

    , which correlates positively with the preoperative lens opacity. Copyright © 2014 Elsevier Inc. All rights reserved.

  2. New dust opacity maps from Viking IR thermal mapper data

    NASA Technical Reports Server (NTRS)

    Martin, T. Z.; Richardson, M. I.

    1992-01-01

    Mapping of dust opacity of the Martian atmosphere, using the silicate-induced absorption of 9 micron radiation, was performed with the Viking Infrared Thermal Mapper (IRTM) data for several local dust storms and in a global sense. We present here the first results from an effort to extend the earlier mapping work to the period of the 1977b major storm, and to concentrate attention on the details of opacity behavior during the initial phases of the 1977a and b storms.

  3. Insights into the beaded filament of the eye lens

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Perng, M.-D.; Zhang Qingjiong; Quinlan, Roy A.

    2007-06-10

    Filensin (BFSP1) and CP49 (BFSP2) represent two members of the IF protein superfamily that are thus far exclusively expressed in the eye lens. Mutations in both proteins cause lens cataract and careful consideration of the detail of these cataract phenotypes alerts us to several interesting features concerning the function of filensin (BFSP1) and CP49 (BFSP2) in the lens. With the first filensin (BFSP1) mutation now having been reported to cause a recessive cataract phenotype, there is the suggestion that the mutation could predispose heterozygote carriers to the early onset of age-related nuclear cataract. In the case of CP49 (BFSP2), theremore » are now three unrelated families who have been identified with a common E233{delta} mutation. Very interestingly this is linked to myopia in one family. Despite the apparent phenotypic differences of the filensin (BFSP1) and CP49 (BFSP2) mutations, the data are still consistent with the beaded filament proteins being essential for lens function and specifically contributing to the optical properties of the lens. The fact that none of the mutations thus far reported affect either the conserved LNDR or TYRKLLEGE motifs that flank the central rod domain supports the view that this pair of IF proteins have unusual structural features and a distinctive assembly mechanism. The multiple sequence divergences suggest these proteins have been adapted to the specific functional requirements of lens fibre cells, a function that can be traced from squid to man.« less

  4. Predicting Rosseland mean opacities of Aluminum using a difference converging method

    NASA Astrophysics Data System (ADS)

    Sun, Weiguo; Fan, Zhixiang; Zhang, Yi; Fu, Jia; Hu, Shide; Zhang, Lulu; Fan, Qunchao

    2018-01-01

    A difference converging method for opacity (DCMo) calculation is suggested to predict opacities and transmissions of metal plasmas at other photon energies that were not measured. The applications of the DCMo to the opacity and transmission calculations of Aluminum plasmas, in the spectral range of 73.5eV ≤ hν ≤ 245eV with Te = 20eV, and of 1475eV ≤ hν ≤ 1540eV with Te = 19eV, show that: 1) the DCMo correctly reproduce all important absorption structures of the Al plasmas and their corresponding intensities; 2) the agreement between the experimental and the DCMo transmissions is notably better than that between the experimental and some other computational transmissions like the ones obtained using OPAL and ATOMIC models.

  5. A Class I UV-Blocking (senofilcon A) Soft Contact Lens Prevents UVA-induced Yellow Fluorescence and NADH loss in the Rabbit Lens Nucleus in vivo

    PubMed Central

    Giblin, Frank J.; Lin, Li-Ren; Simpanya, Mukoma F.; Leverenz, Victor R.; Fick, Catherine E.

    2012-01-01

    It is known that fluorescence, much of it caused by UVA light excitation, increases in the aging human lens, resulting in loss of sharp vision. This study used an in vivo animal model to investigate UVA-excited fluorescence in the rabbit lens, which contains a high level of the UVA chromophore NADH, existing both free and bound to λ-crystallin. Also, the ability of a Class I (senofilcon A) soft contact lens to protect against UVA-induced effects on the rabbit lens was tested. Rabbit eyes were irradiated with UVA light in vivo (100 mW/cm2 on the cornea) for 1 hour using monochromatic 365 nm light. Irradiation was conducted in the presence of either a senofilcon A contact lens, a minimally UV-absorbing lotrafilcon A contact lens, or no contact lens at all. Eyes irradiated without a contact lens showed blue 365 nm-excited fluorescence initially, but this changed to intense yellow fluorescence after 1 hour. Isolated, previously irradiated lenses exhibited yellow fluorescence originating from the lens nucleus when viewed under 365 nm light, but showed normal blue fluorescence arising from the cortex. Previously irradiated lenses also exhibited a faint yellow color when observed under visible light. The senofilcon A contact lens protected completely against the UVA-induced effects on fluorescence and lens yellowing, whereas the lotrafilcon A lens showed no protection. The UVA-exposure also produced a 53% loss of total NADH (free plus bound) in the lens nucleus, with only a 13% drop in the anterior cortex. NADH loss in the nucleus was completely prevented with use of a senofilcon A contact lens, but no significant protection was observed with a lotrafilcon A lens. Overall, the senofilcon A lens provided an average of 67% protection against UVA-induced loss of four pyridine nucleotides in four different regions of the lens. HPLC analysis with fluorescence detection indicated a nearly six-fold increase in 365 nm-excited yellow fluorescence arising from lens nuclear

  6. LENS: μLENS Simulations, Analysis, and Results

    NASA Astrophysics Data System (ADS)

    Rasco, Charles

    2013-04-01

    Simulations of the Low-Energy Neutrino Spectrometer prototype, μLENS, have been performed in order to benchmark the first measurements of the μLENS detector at the Kimballton Underground Research Facility (KURF). μLENS is a 6x6x6 celled scintillation lattice filled with Linear Alkylbenzene based scintillator. We have performed simulations of μLENS using the GEANT4 toolkit. We have measured various radioactive sources, LEDs, and environmental background radiation measurements at KURF using up to 96 PMTs with a simplified data acquisition system of QDCs and TDCs. In this talk we will demonstrate our understanding of the light propagation and we will compare simulation results with measurements of the μLENS detector of various radioactive sources, LEDs, and the environmental background radiation.

  7. Continuous opacity from Ne^-

    NASA Astrophysics Data System (ADS)

    John, T. L.

    1996-04-01

    Free-free absorption coefficients of the negative neon ion are calculated by the phase-shift approximation based on multiconfiguration Hartree-Fock continuum wave functions. These wave functions accurately account for electron-neon correlation and polarization, and yield scattering cross-sections in excellent agreement with the latest experimental values. The coefficients are expected to give the best current estimates of Ne^- continuous absorption. We find that Ne^- makes only a small contribution (less than 0.3 per cent) to stellar opacities, including hydrogen-deficient stars with enhanced Ne abundances.

  8. Validating solar and solar-like star opacities

    NASA Astrophysics Data System (ADS)

    Le Pennec, Maëlle; TURCK-CHIEZE, Sylvaine; RIBEYRE, Xavier; DUCRET, Jean-Eric; BLANCARD, Christophe; COSSE, Philippe; MONDET, Guillaume; FAUSSURIER, Gérald

    2015-08-01

    The Sun is, as being our closest star, a privilege place to test and validate physics. However, the solar physics is not yet completely understood. Indeed, since the recent update of the solar composition, there are differences between solar models and seismic data, visible on the solar sound speed profile comparison. This well established large discrepancy (Turck-Chièze et al. 2001, 2004, 2011, Christensen-Dalsgaard et al. 2009, Basu et al. 2015) could be linked to radiative transfer issue.Two directions of investigation are proposed. One possibility to explain this gap could be that the Sun produces slightly more energy that it liberates on its surface (around 5%). This energy could be transformed into macroscopic motions in the radiative zone, which are not taken into account in the solar standard model. Another explanation could be that the calculations of energy transport are not correctly taken into account either on the calculation of the Rosseland mean values or in the treatment of the radiative acceleration. This could have an impact on the determination of the internal solar abundances.Unfortunately, there are very few experiments to validate these calculations (Bailey et al. 2014). That's why we are proposing an opacity experiment on a high-energy laser like LMJ, in the conditions of the radiative zone (T=[2 - 15.106 K] and ρ=[0.2 - 150 g/cm3]). The aim is to measure the opacity of the most important contributors to the global opacity in this solar area : iron, oxygen and silicon. We are exploiting in that purpose a technical approach called the Double Ablation Front. During the laser-plasma interaction, the plasma radiative effects allow to reach these high temperatures and densities at LTE and validate or not plasma effects and line widths. We will show the principle of this technique and the results of our simulations on several elements.In the mean time, we are also exploiting new opacity calculations thanks to the OPAS code (Blancard et al. 2012

  9. Surface thermodynamics and adhesion forces governing bacterial transmission in contact lens related microbial keratitis.

    PubMed

    Qu, Wenwen; Busscher, Henk J; Hooymans, Johanna M M; van der Mei, Henny C

    2011-06-15

    Contact lens induced microbial keratitis results from bacterial transmission from one surface to another. We investigated the adhesion forces of Pseudomonas aeruginosa, Staphylococci and Serratia to different contact lenses, lens cases and corneal surfaces using AFM, and applied a Weibull analysis on these adhesion forces to calculate bacterial transmission probabilities from lens case to corneas with a contact lens as an intermediate. Also a new surface thermodynamic parameter was introduced, the interfacial free energy of transmission, which in essence compares the interfacial free energies of bacterial adhesion, calculated from measured contact angles with liquids on the donating and receiving surfaces in the transmission process. Bacterial adhesion forces were generally strongest among all eight strains for the lens case (-6.5 to -12.0 nN) and corneas (-3.5 to -11.5 nN), while contact lenses (-0.6 to -13.1 nN) exerted slightly smaller adhesion forces. Consequently, bacterial transmission from lens case to contact lens yielded a smaller contribution in the final transmission than from contact lens to cornea. Bacterial transmission probabilities as derived from force analyses were higher when the interfacial free energies of transmission were more negative, which is in line with surface thermodynamic principles. Therewith this parameter could provide useful in analyzing other bacterial transmission phenomena between donating and receiving surfaces as well. Copyright © 2011 Elsevier Inc. All rights reserved.

  10. The Relationship between Crystalline Lens Power and Refractive Error in Older Chinese Adults: The Shanghai Eye Study.

    PubMed

    He, Jiangnan; Lu, Lina; He, Xiangui; Xu, Xian; Du, Xuan; Zhang, Bo; Zhao, Huijuan; Sha, Jida; Zhu, Jianfeng; Zou, Haidong; Xu, Xun

    2017-01-01

    To report calculated crystalline lens power and describe the distribution of ocular biometry and its association with refractive error in older Chinese adults. Random clustering sampling was used to identify adults aged 50 years and above in Xuhui and Baoshan districts of Shanghai. Refraction was determined by subjective refraction that achieved the best corrected vision based on monocular measurement. Ocular biometry was measured by IOL Master. The crystalline lens power of right eyes was calculated using modified Bennett-Rabbetts formula. We analyzed 6099 normal phakic right eyes. The mean crystalline lens power was 20.34 ± 2.24D (range: 13.40-36.08). Lens power, spherical equivalent, and anterior chamber depth changed linearly with age; however, axial length, corneal power and AL/CR ratio did not vary with age. The overall prevalence of hyperopia, myopia, and high myopia was 48.48% (95% CI: 47.23%-49.74%), 22.82% (95% CI: 21.77%-23.88%), and 4.57% (95% CI: 4.05-5.10), respectively. The prevalence of hyperopia increased linearly with age while lens power decreased with age. In multivariate models, refractive error was strongly correlated with axial length, lens power, corneal power, and anterior chamber depth; refractive error was slightly correlated with best corrected visual acuity, age and sex. Lens power, hyperopia, and spherical equivalent changed linearly with age; Moreover, the continuous loss of lens power produced hyperopic shifts in refraction in subjects aged more than 50 years.

  11. 40 CFR 60.1760 - What is required for my continuous opacity monitoring system and how are the data used?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... opacity monitoring system and how are the data used? 60.1760 Section 60.1760 Protection of Environment... continuous opacity monitoring system and how are the data used? (a) Install, calibrate, maintain, and operate a continuous opacity monitoring system. (b) Install, evaluate, and operate each continuous opacity...

  12. The Influence of Different OK Lens Designs on Peripheral Refraction.

    PubMed

    Kang, Pauline; Swarbrick, Helen

    2016-09-01

    To compare peripheral refraction changes along the horizontal and vertical meridians induced by three different orthokeratology (OK) lens designs: BE, Paragon CRT, and Contex lenses. Nineteen subjects (6M, 13F, mean age 28 ± 7 years) were initially fitted with BE OK lenses in both eyes which were worn overnight for 14 days. Central and peripheral refraction and corneal topography were measured at baseline and after 14 nights of lens wear. After a minimum 2-week washout period, one randomly selected eye was re-fitted with a Paragon CRT lens and the other eye with a Contex OK lens. Measurements were repeated before and after 14 nights of lens wear. The three different OK lenses caused significant changes in peripheral refraction along both the horizontal and vertical visual fields (VFs). BE and Paragon CRT lenses induced a significant hyperopic shift within the central ±20° along the horizontal VF and at all positions along the vertical meridian except at 30° in the superior VF. There were no significant differences in peripheral refraction changes induced between BE and Paragon CRT lenses. When comparing BE and Contex OK lens designs, BE caused greater hyperopic shifts at 10° and 30° in the temporal VF and at center, 10°, and 20° in the superior VF along the vertical meridian. Furthermore, BE lenses caused greater reduction in Flat and Steep K values compared to Contex OK. OK lenses induced significant changes in peripheral refraction along the horizontal and vertical meridians. Despite the clinically significant difference in central corneal flattening induced by BE and Contex OK lenses, relative peripheral refraction changes differed minimally between the three OK lens designs. If the peripheral retina influences refractive error development, these results suggest that myopia control effects are likely to be similar between different OK lens designs.

  13. 40 CFR 63.1357 - Temporary, conditioned exemption from particulate matter and opacity standards.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... particulate matter and opacity standards. 63.1357 Section 63.1357 Protection of Environment ENVIRONMENTAL... Cement Manufacturing Industry Other § 63.1357 Temporary, conditioned exemption from particulate matter... methods) is exempt from: (1) Any particulate matter and opacity standards of part 60 or part 63 of this...

  14. Oxygen transport through soft contact lens and cornea: Lens characterization and metabolic modeling

    NASA Astrophysics Data System (ADS)

    Chhabra, Mahendra

    The human cornea requires oxygen to sustain metabolic processes critical for its normal functioning. Any restriction to corneal oxygen supply from the external environment (e.g., by wearing a low oxygen-permeability contact lens) can lead to hypoxia, which may cause corneal edema (swelling), limbal hyperemia, neovascularization, and corneal acidosis. The need for adequate oxygen to the cornea is a major driving force for research and development of hypertransmissible soft contact lenses (SCLs). Currently, there is no standard technique for measuring oxygen permeability (Dk) of hypertransmissible silicone-hydrogel SCLs. In this work, an electrochemistry-based polarographic apparatus was designed, built, and operated to measure oxygen permeability in hypertransmissible SCLs. Unlike conventional methods where a range of lens thickness is needed for determining oxygen permeabilities of SCLs, this apparatus requires only a single lens thickness. The single-lens permeameter provides a reliable, efficient, and economic tool for measuring oxygen permeabilities of commercial hypertransmissible SCLs. The single-lens permeameter measures not only the product Dk, but, following modification, it measures separately diffusivity, D, and solubility, k, of oxygen in hypertransmissible SCLs. These properties are critical for designing better lens materials that ensure sufficient oxygen supply to the cornea. Metabolism of oxygen in the cornea is influenced by contact-lens-induced hypoxia, diseases such as diabetes, surgery, and drug treatment, Thus, estimation of the in-vivo corneal oxygen consumption rate is essential for gauging adequate oxygen supply to the cornea. Therefore, we have developed an unsteady-state reactive-diffusion model for the cornea-contact-lens system to determine in-vivo human corneal oxygen-consumption rate. Finally, a metabolic model was developed to determine the relation between contact-lens oxygen transmissibility (Dk/L) and corneal oxygen deficiency. A

  15. Immunoglobulin Concentration in Tears of Contact Lens Wearers

    PubMed Central

    Maurya, Rajendra P.; Bhushan, Prashant; Singh, Virendra P.; Singh, Mahendra K.; Kumar, Prakash; Bhatia, Ravindra P.S.; Singh, Usha

    2014-01-01

    Purpose: To evaluate changes in the concentration of tear immunoglobulins in contact lens wearers. Methods: A total of 45 cases including 23 contact lens wearers (43 eyes) and 22 age and sex matched healthy controls having no ocular pathology were studied for immunoglobulins (IgA, IgG, IgM) in their tears by single radial immunodiffusion method. Results: Most of the cases used soft (56.6%) and semi-soft gas permeable (30.4%) contact lenses. Tear IgM was detected in only 17.4% and tear IgG in 43.6% of contact lens wearers, while in controls IgG was detected in 9.1% but none of the controls had IgM. There was a significant rise in total tear IgA (13.17 ± 4.44 mg/dl) in contact lens wearer as compared to controls (8.93 ± 3.79 mg/dl). Rise of tear IgA was more in symptomatic patients (15.38 ± 5.28 mg/dl) and in those wearing hard (19.73 ± 5.43 mg/dl) and semi-soft contact lenses (13.31 ± 5.43 mg/dl). A significant increase in tear IgA was noticed in subjects wearing lenses for >3 years (15.69 ± 5.39 mg/dl). About 43.4% of lens wearers were symptomatic and 80% of their lenses showed deposits and/or haziness. All cases with IgM in tear were symptomatic. Conclusion: The relation of immunoglobulin concentration with increasing duration of wear and material of contact lens shows that tear immunoglobulin rise accrues due to mechanical stimulation, hence contact lenses should not be used for a long period and lenses of hard nature should be discouraged. The maintenance, cleaning and deproteinization of the lenses are of high importance to avoid immunostimulation. PMID:25667732

  16. Web-based OPACs: Between Tradition and Innovation.

    ERIC Educational Resources Information Center

    Moscoso, Purificacion; Ortiz-Repiso, Virginia

    1999-01-01

    Analyzes the change that Internet-based OPACs (Online Public Access Catalogs) have represented to the structure, administration, and maintenance of the catalogs, retrieval systems, and user interfaces. Examines the structure of databases and traditional principles that have governed systems development. Discusses repercussions of the application…

  17. Potentiation of intraocular absorption and drug metabolism of N-acetylcarnosine lubricant eye drops: drug interaction with sight threatening lipid peroxides in the treatment for age-related eye diseases.

    PubMed

    Babizhayev, Mark A

    2009-01-01

    Cataract is the dominant cause of blindness worldwide. Studies of the morphological structure and biophysical changes of the lens in human senile cataracts have demonstrated the disappearance of normal fiber structure in the opaque region of the lens and the disintegration of the lens fiber plasma membrane in the lens tissue. Morphological and biochemical techniques have revealed the regions in human cataractous lenses in which the plasma membrane derangement occurs as the primary light scattering centers which cause the observed lens opacity. Human cataract formation is mostly considered to be a multifactorial disease; however, oxidative stress might be one of the leading causes for both nuclear and cortical cataract. Phospholipid molecules modified with oxygen, accumulating in the lipid bilayer, change its geometry and impair lipid-lipid and protein-lipid interactions in lenticular fiber membranes. Electron microscopy data of human lenses at various stages of age-related cataract document that these disruptions were globules, vacuoles, multilamellar membranes, and clusters of highly undulating membranes. The opaque shades of cortical cataracts represent cohorts of locally affected fibres segregated from unaffected neighbouring fibres by plasma membranes. Other potential scattering centers found throughout the mature cataract nucleus included variations in staining density between adjacent cells, enlarged extracellular spaces between undulating membrane pairs, and protein-like deposits in the extracellular space. These affected parts had membranes with a fine globular aspect and in cross-section proved to be filled with medium to large globular elements. Lipid peroxidation (LPO) is a pathogenetic and causative factor of cataract. Increased concentrations of primary molecular LPO products (diene conjugates, lipid hydroperoxides, fatty acid oxy-derivatives) and end fluorescent LPO products were detected in the lipid moieties of the aqueous humor samples and human

  18. Wider pulsation instability regions for β Cephei and SPB stars calculated using new Los Alamos opacities

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Walczak, Przemysław; Fontes, Christopher John; Colgan, James Patrick

    Here, our goal is to test the newly developed OPLIB opacity tables from Los Alamos National Laboratory and check their influence on the pulsation properties of B-type stars. We calculated models using MESA and Dziembowski codes for stellar evolution and linear, nonadiabatic pulsations, respectively. We derived the instability domains of β Cephei and SPB-types for different opacity tables OPLIB, OP, and OPAL. As a result, the new OPLIB opacities have the highest Rosseland mean opacity coefficient near the so-called Z-bump. Therefore, the OPLIB instability domains are wider than in the case of OP and OPAL data.

  19. Wider pulsation instability regions for β Cephei and SPB stars calculated using new Los Alamos opacities

    DOE PAGES

    Walczak, Przemysław; Fontes, Christopher John; Colgan, James Patrick; ...

    2015-08-13

    Here, our goal is to test the newly developed OPLIB opacity tables from Los Alamos National Laboratory and check their influence on the pulsation properties of B-type stars. We calculated models using MESA and Dziembowski codes for stellar evolution and linear, nonadiabatic pulsations, respectively. We derived the instability domains of β Cephei and SPB-types for different opacity tables OPLIB, OP, and OPAL. As a result, the new OPLIB opacities have the highest Rosseland mean opacity coefficient near the so-called Z-bump. Therefore, the OPLIB instability domains are wider than in the case of OP and OPAL data.

  20. Dose estimation to eye lens of industrial gamma radiography workers using the Monte Carlo method.

    PubMed

    de Lima, Alexandre Roza; Hunt, John Graham; Da Silva, Francisco Cesar Augusto

    2017-12-01

    The ICRP Statement on Tissue Reactions (2011), based on epidemiological evidence, recommended a reduction for the eye lens equivalent dose limit from 150 to 20 mSv per year. This paper presents mainly the dose estimations received by industrial gamma radiography workers, during planned or accidental exposure to the eye lens, Hp(10) and effective dose. A Brazilian Visual Monte Carlo Dose Calculation program was used and two relevant scenarios were considered. For the planned exposure situation, twelve radiographic exposures per day for 250 days per year, which leads to a direct exposure of 10 h per year, were considered. The simulation was carried out using a 192 Ir source with 1.0 TBq of activity; a source/operator distance between 5 and 10 m and placed at heights of 0.02 m, 1 m and 2 m, and an exposure time of 12 s. Using a standard height of 1 m, the eye lens doses were estimated as being between 16.3 and 60.3 mGy per year. For the accidental exposure situation, the same radionuclide and activity were used, but in this case the doses were calculated with and without a collimator. The heights above ground considered were 1.0 m, 1.5 m and 2.0 m; the source/operator distance was 40 cm, and the exposure time 74 s. The eye lens doses at 1.5 m were 12.3 and 0.28 mGy without and with a collimator, respectively. The conclusions were that: (1) the estimated doses show that the 20 mSv annual limit for eye lens equivalent dose can directly impact industrial gamma radiography activities, mainly in industries with high number of radiographic exposures per year; (2) the risk of lens opacity has a low probability for a single accident, but depending on the number of accidental exposures and the dose levels found in planned exposures, the threshold dose can easily be exceeded during the professional career of an industrial radiography operator, and; (3) in a first approximation, Hp(10) can be used to estimate the equivalent dose to the eye lens.

  1. Smart lens: tunable liquid lens for laser tracking

    NASA Astrophysics Data System (ADS)

    Lin, Fan-Yi; Chu, Li-Yu; Juan, Yu-Shan; Pan, Sih-Ting; Fan, Shih-Kang

    2007-05-01

    A tracking system utilizing tunable liquid lens is proposed and demonstrated. Adapting the concept of EWOD (electrowetting-on-dielectric), the curvature of a droplet on a dielectric film can be controlled by varying the applied voltage. When utilizing the droplet as an optical lens, the focal length of this adaptive liquid lens can be adjusted as desired. Moreover, the light that passes through it can therefore be focused to different positions in space. In this paper, the tuning range of the curvature and focal length of the tunable liquid lens is investigated. Droplet transformation is observed and analyzed under a CCD camera. A tracking system combining the tunable liquid lens with a laser detection system is also proposed. With a feedback circuit that maximizing the returned signal by controlling the tunable lens, the laser beam can keep tracked on a distant reflected target while it is moving.

  2. A Stochastic Model of Eye Lens Growth

    PubMed Central

    Šikić, Hrvoje; Shi, Yanrong; Lubura, Snježana; Bassnett, Steven

    2015-01-01

    The size and shape of the ocular lens must be controlled with precision if light is to be focused sharply on the retina. The lifelong growth of the lens depends on the production of cells in the anterior epithelium. At the lens equator, epithelial cells differentiate into fiber cells, which are added to the surface of the existing fiber cell mass, increasing its volume and area. We developed a stochastic model relating the rates of cell proliferation and death in various regions of the lens epithelium to deposition of fiber cells and lens growth. Epithelial population dynamics were modeled as a branching process with emigration and immigration between various proliferative zones. Numerical simulations were in agreement with empirical measurements and demonstrated that, operating within the strict confines of lens geometry, a stochastic growth engine can produce the smooth and precise growth necessary for lens function. PMID:25816743

  3. The Lens Capsule

    PubMed Central

    Danysh, Brian P.; Duncan, Melinda K.

    2009-01-01

    The lens capsule is a modified basement membrane that completely surrounds the ocular lens. It is known that this extracellular matrix is important for both the structure and biomechanics of the lens in addition to providing informational cues to maintain lens cell phenotype. This review covers the development and structure of the lens capsule, lens diseases associated with mutations in extracellular matrix genes and the role of the capsule in lens function including those proposed for visual accommodation, selective permeability to infectious agents, and cell signaling. PMID:18773892

  4. Treatment of atomic and molecular line blanketing by opacity sampling. [atmospheric optics - stellar atmospheres

    NASA Technical Reports Server (NTRS)

    Johnson, H. R.; Krupp, B. M.

    1975-01-01

    An opacity sampling (OS) technique for treating the radiative opacity of large numbers of atomic and molecular lines in cool stellar atmospheres is presented. Tests were conducted and results show that the structure of atmospheric models is accurately fixed by the use of 1000 frequency points, and 500 frequency points is often adequate. The effects of atomic and molecular lines are separately studied. A test model computed by using the OS method agrees very well with a model having identical atmospheric parameters computed by the giant line (opacity distribution function) method.

  5. The Relationship between Crystalline Lens Power and Refractive Error in Older Chinese Adults: The Shanghai Eye Study

    PubMed Central

    He, Jiangnan; Lu, Lina; He, Xiangui; Xu, Xian; Du, Xuan; Zhang, Bo; Zhao, Huijuan; Sha, Jida; Zhu, Jianfeng; Zou, Haidong; Xu, Xun

    2017-01-01

    Purpose To report calculated crystalline lens power and describe the distribution of ocular biometry and its association with refractive error in older Chinese adults. Methods Random clustering sampling was used to identify adults aged 50 years and above in Xuhui and Baoshan districts of Shanghai. Refraction was determined by subjective refraction that achieved the best corrected vision based on monocular measurement. Ocular biometry was measured by IOL Master. The crystalline lens power of right eyes was calculated using modified Bennett-Rabbetts formula. Results We analyzed 6099 normal phakic right eyes. The mean crystalline lens power was 20.34 ± 2.24D (range: 13.40–36.08). Lens power, spherical equivalent, and anterior chamber depth changed linearly with age; however, axial length, corneal power and AL/CR ratio did not vary with age. The overall prevalence of hyperopia, myopia, and high myopia was 48.48% (95% CI: 47.23%–49.74%), 22.82% (95% CI: 21.77%–23.88%), and 4.57% (95% CI: 4.05–5.10), respectively. The prevalence of hyperopia increased linearly with age while lens power decreased with age. In multivariate models, refractive error was strongly correlated with axial length, lens power, corneal power, and anterior chamber depth; refractive error was slightly correlated with best corrected visual acuity, age and sex. Conclusion Lens power, hyperopia, and spherical equivalent changed linearly with age; Moreover, the continuous loss of lens power produced hyperopic shifts in refraction in subjects aged more than 50 years. PMID:28114313

  6. Opacity Variations in the Ionized Absorption in NGC 3783: A Compact Absorber

    NASA Astrophysics Data System (ADS)

    Krongold, Y.; Nicastro, F.; Brickhouse, N. S.; Elvis, M.; Mathur, S.

    2005-04-01

    We show that the Fe VII-Fe XII M-shell unresolved transition array (UTA) in the Chandra HETGS observation of NGC 3783 (900 ks) clearly changes in opacity on a timescale of 31 days, responding to a factor of ~2 change in the ionizing continuum. The opacity variation is observed at a level >10 σ. There is also evidence for variability in the O VI K edge (at ~3 σ). The observed changes are consistent with the gas producing these absorption features (i.e., the low-ionization component) being close to photoionization equilibrium. The gas responsible for the Fe XVII-Fe XXII L-shell absorption (i.e., the high-ionization component) does not seem to be responding as expected in photoionization equilibrium. The observed change in opacity for the UTA implies a density >1×104 cm-3, thus locating the gas within 6 pc of the X-ray source. The scenario in which the gas is composed of a continuous radial range of ionization structures is ruled out, as in such scenario, no opacity variations are expected. Rather, the structure of the absorber is likely composed of heavily clumped gas.

  7. Measuring opacities for high energy density matter

    DOE PAGES

    Bailey, James E.

    2015-07-01

    How does energy propagate from the solar core to the surface of the sun, where it emerges to warm the Earth? How old are the stellar systems that host the numerous exoplanets that have now been discovered outside our solar system? How does radiation penetrate and heat an inertial fusion capsule? The answers to these seemingly disparate questions hinge on knowledge of the fundamental material property that controls the absorption of radiation: opacity. Opacity plays a critical role for many high energy density (HED) systems and is highly important for the NNSA stewardship mission. In addition, laboratory astrophysics research servesmore » as a conduit for establishing collaborations between the NNSA laboratories, between the NNSA laboratories and universities, and between the NNSA laboratories and our international partners. Exposure to open peer review sharpens the research capabilities and interactions of NNSA scientists with students and professors as a natural path for recruiting the next generation of stockpile stewards.« less

  8. Expression of the sodium potassium chloride cotransporter (NKCC1) and sodium chloride cotransporter (NCC) and their effects on rat lens transparency.

    PubMed

    Chee, K N; Vorontsova, I; Lim, J C; Kistler, J; Donaldson, P J

    2010-05-04

    To characterize the expression patterns of the Na+-K+-Cl(-) cotransporter (NKCC) 1 and NKCC2, and the Na+-Cl(-) cotransporter (NCC) in the rat lens and to determine if they play a role in regulating lens volume and transparency. RT-PCR was performed on RNA extracted from fiber cells to identify sodium dependent cotransporters expressed in the rat lens. Western blotting and immunohistochemistry, using NKCC1, NKCC2, and NCC antibodies, were used to verify expression at the protein level and to localize transporter expression. Organ cultured rat lenses were incubated in Artificial Aqueous Humor (AAH) of varying osmolarities or isotonic AAH that contained either the NKCC specific inhibitor bumetanide, or the NCC specific inhibitor thiazide for up to 18 h. Lens transparency was monitored with dark field microscopy, while tissue morphology and antibody labeling patterns were recorded using a confocal microscope. Molecular experiments showed that NKCC1 and NCC were expressed in the lens at both the transcript and protein levels, but NKCC2 was not. Immunohistochemistry showed that both NKCC1 and NCC were expressed in the lens cortex, but NCC expression was also found in the lens core. In the lens cortex the majority of labeling for both transporters was cytoplasmic in nature, while in the lens core, NCC labeling was associated with the membrane. Exposure of lenses to either hypotonic or hypertonic AAH had no noticeable effects on the predominantly cytoplasmic location of either transporter in the lens cortex. Incubation of lenses in isotonic AAH plus the NKCC inhibitor bumetanide for 18 h induced a cortical opacity that was initiated by a shrinkage of peripheral fiber cells and the dilation of the extracellular space between fiber cells in a deeper zone located some approximately 150 microm in from the capsule. In contrast, lenses incubated in isotonic AAH and the NCC inhibitor thiazide maintained both their transparency and their regular fiber cell morphology. We have

  9. Age determination of raccoons

    USGS Publications Warehouse

    Grau, G.A.; Sanderson, G.C.; Rogers, J.P.

    1970-01-01

    Age criteria, based on 61 skulls and eye lenses from 103 known-age captives, are described for separating raccoons (Procyon lotor) into eight age-classes as follows: young-of-the-year, 1, 2, 3, 4, 5, 6-7, > 7 years. Criteria studied were eye lens nitrogen, cranial suture closure, tooth wear and incisor cementum layers. Lens nitrogen increased rapidly up to 12 months of age, but at much reduced rate thereafter. Total lens nitrogen was useful only in separating young-of-the-year from adults. The closure sequence for five cranial sutures accurately divided the total known-age sample of males into seven groups, and the adults into five groups. The tooth wear criteria divided the known-age sample into five relative age groups, but aging of individuals by this method was inaccurate. Histological sectioning of known-age teeth was the best method of observing layering in the cementum tissue. The technique of basing estimation of age on cementum ring counts, although subjective, was accurate for aging individuals through their fourth year but tended to underestimate the age of animals over 4 years old. However, suture closure or tooth wear can be used to identify males over 4 years old. In field studies, technical difficulties limit the utility of age estimation by cementum layers. Maximum root thickness of the lower canine was accurate in determining the sex of individuals from 5 months to ,at least 48 months of age.

  10. Models of H II regions - Heavy element opacity, variation of temperature

    NASA Technical Reports Server (NTRS)

    Rubin, R. H.

    1985-01-01

    A detailed set of H II region models that use the same physics and self-consistent input have been computed and are used to examine where in parameter space the effects of heavy element opacity is important. The models are briefly described, and tabular data for the input parameters and resulting properties of the models are presented. It is found that the opacities of C, Ne, O, and to a lesser extent N play a vital role over a large region of parameter space, while S and Ar opacities are negligible. The variation of the average electron temperature T(e) of the models with metal abundance, density, and T(eff) is investigated. It is concluded that by far the most important determinator of T(e) is metal abundance; an almost 7000 K difference is expected over the factor of 10 change from up to down abundances.

  11. Tamper asymmetry and its effect on transmission for x-ray driven opacity simulations

    DOE PAGES

    Morris, H. E.; Tregillis, I. L.; Hoffman, N. M.; ...

    2017-08-01

    This paper reports on synthetic transmission results from Lasnex [1] radiation-hydrodynamics simulations of opacity experiments carried out at Sandia National Laboratories' recently upgraded ZR facility. The focus is on experiments utilizing disk targets composed of a half-moon Fe/Mg mixture tamped on either end with 10- m CH and an additional 35- m beryllium tamper accessory on the end facing the spectrometer. Five x-ray sources with peak power ranging from 10 to 24 TW were used in the simulations to heat and backlight the opacity target. The dominant effect is that the beryllium behind the Fe/Mg mixture is denser and moremore » opaque than the beryllium unshielded by metal during the times of greatest importance for the transmission measurement for all drives. This causes the simulated transmission to be lower than expected, and this is most pronounced for the case using the lowest drive power. While beryllium has a low opacity, its areal density is sufficiently high such that the expected reduction of the measured transmission is significant. This situation leads to an overestimate of iron opacity by 10-215% for a photon energy range of 975- 1775 eV for the 10-TW case. It is shown that if the tamper conditions are known, the transmission through each component of the target can be calculated and the resulting opacity can be corrected.« less

  12. Refractive index measurement of the mouse crystalline lens using optical coherence tomography

    PubMed Central

    Chakraborty, Ranjay; Lacy, Kip D.; Tan, Christopher C.; Park, Han na; Pardue, Machelle T.

    2014-01-01

    In recent years, there has been a growing interest for using mouse models in refractive development and myopia research. The crystalline lens is a critical optical component of the mouse eye that occupies greater than 50% of the ocular space, and significant increases in thickness with age. However, changes in refractive index of the mouse crystalline lens are less known. In this study, we examined the changes in thickness and refractive index of the mouse crystalline lens for two different strains, wild-type (WT) and a nyx mutant (nob) over the course of normal visual development or after form deprivation. Refractive index and lens thickness measurements were made on ex vivo lens using spectral domain optical coherence tomography (SD-OCT). Comparison of refractive index measurements on 5 standard ball lenses using the SD-OCT and their known refractive indices (manufacturer provided) indicated good precision (intra-class correlation coefficient, 0.998 and Bland-Altman coefficient of repeatability, 0.116) of the SD-OCT to calculate mouse lens refractive index ex vivo. During normal visual development, lens thickness increased significantly with age for three different cohorts of mice, aged 4 (average thickness from both eyes; WT: 1.78 ± 0.03, nob: 1.79 ± 0.08 mm), 10 (WT: 2.02 ± 0.05, nob: 2.01 ± 0.04 mm) and 16 weeks (WT: 2.12 ± 0.06, nob: 2.09 ± 0.06 mm, p<0.001). Lens thickness was not significantly different between the two strains at any age (p=0.557). For mice with normal vision, refractive index for isolated crystalline lenses in nob mice was significantly greater than WT mice (mean for all ages; WT: 1.42 ± 0.01, nob: 1.44 ± 0.001, p<0.001). After 4 weeks of form deprivation to the right eye using a skull-mounted goggling apparatus, a thinning of the crystalline lens was observed in both right and left eyes of goggled animals compared to their naïve controls (average from both the right and the left eye) for both strains (p=0.052). In form deprived

  13. Modified cataract surgery with telescopic magnification for patients with age-related macular degeneration.

    PubMed

    Iizuka, Megumi; Gorfinkel, John; Mandelcorn, Mark; Lam, Wai-Ching; Devenyi, Robert; Markowitz, Samuel N

    2007-12-01

    The most desirable effect following cataract surgery in the presence of age-related macular degeneration (AMD) is to obtain an improvement in distance resolution acuity, and the only optical solution to this is the use of telescopic magnification. The purpose of the study was to develop and verify the clinical utility of inducing low-grade telescopic magnification (<33%) at the time of cataract surgery by the choice of an appropriate intraocular lens power and spectacle glasses in patients with AMD and cataract. The design was a prospective, nonrandomized, interventional case series involving 6 patients aged 74-86 (mean 80; SD 4) years with AMD and cataract. Participants were males and females, equal in number, who had visual acuity of less than 20/400 in the weaker eye. Standard cataract surgery was performed in the weaker eye. The power of the intraocular lens was derived from the reduced Gullstrand model of the eye in such a way that at the intraocular lens plane a minus lens was created, which, together with a plus lens in matching glasses, formed a Galilean telescopic system with magnification of up to 33%. Outcome measures were visual acuity, contrast sensitivity, and activities of daily living (ADL) scores. The mean power of the implanted intraocular lenses was 6.31 (SD 2.42) diopters and, according to the theoretical derivations, achieved magnification between 20% and 30% (mean 26%; SD 4.92%). Visual acuity improved for the group from a mean of 20/525 (logMAR 1.48; SD 0.13) to a mean of 20/290 (logMAR 1.20; SD 0.21). Contrast sensitivity improved significantly (p < 0.001) only in the lower spatial frequencies. Postoperatively, ADL scores improved significantly in all patients except one. At the end of the follow-up period, 3 patients reported that they would like to proceed with similar surgery for the other eye. An optimal surgical telescopic device based on low-grade telescopic magnification may improve functional vision for usage in all tasks in AMD

  14. AKT activation promotes PTEN hamartoma tumor syndrome–associated cataract development

    PubMed Central

    Sellitto, Caterina; Li, Leping; Gao, Junyuan; Robinson, Michael L.; Lin, Richard Z.; Mathias, Richard T.; White, Thomas W.

    2013-01-01

    Mutations in the human phosphatase and tensin homolog (PTEN) gene cause PTEN hamartoma tumor syndrome (PHTS), which includes cataract development among its diverse clinical pathologies. Currently, it is not known whether cataract formation in PHTS patients is secondary to other systemic problems, or the result of the loss of a critical function of PTEN within the lens. We generated a mouse line with a lens-specific deletion of Pten (PTEN KO) and identified a regulatory function for PTEN in lens ion transport. Specific loss of PTEN in the lens resulted in cataract. PTEN KO lenses exhibited a progressive age-related increase in intracellular hydrostatic pressure, along with, increased intracellular sodium concentrations, and reduced Na+/K+-ATPase activity. Collectively, these defects lead to lens swelling, opacities and ultimately organ rupture. Activation of AKT was highly elevated in PTEN KO lenses compared to WT mice. Additionally, pharmacological inhibition of AKT restored normal Na+/K+-ATPase activity in primary cultured lens cells and reduced lens pressure in intact lenses from PTEN KO animals. These findings identify a direct role for PTEN in the regulation of lens ion transport through an AKT-dependent modulation of Na+/K+-ATPase activity, and provide a new animal model to investigate cataract development in PHTS patients. PMID:24270425

  15. TI-59 PROGRAMMABLE CALCULATOR PROGRAMS FOR IN-STACK OPACITY, VENTURI SCRUBBERS, AND ELECTROSTATIC PRECIPITATORS

    EPA Science Inventory

    The report explains the basic concepts of in-stack opacity as measured by in-stack opacity monitors. Also included are calculator programs that model the performance of venturi scrubbers and electrostatic precipitators. The effect of particulate control devices on in-stack opacit...

  16. The (lack of) relation between straylight and visual acuity. Two domains of the point-spread-function.

    PubMed

    van den Berg, Thomas J T P

    2017-05-01

    The effect of cataract and other media opacities on functional vision is typically assessed clinically using visual acuity. In both clinical and basic research, straylight (the functional result of light scattering in the eye) is commonly measured. The purpose of the present study was to determine the link between these two measures: is visual acuity in cataract and other media opacities related to straylight? Interdependence between acuity and straylight is addressed from three different points of view: (1) Methodological: can acuity differences affect the measurement value of straylight, and vice versa? (2) Basic optics: does the optical process of light scattering in the human eye affect both straylight and visual acuity? (3) Statistical: how strongly are acuity and straylight correlated in the practice of important clinical conditions? Experimental and theoretical aspects will be considered, with a focus on normal ageing and cataract formation. (1) Methodological: testing potential effects of acuity, artificially manipulated with positive trial lenses, showed no effect on measured straylight values. Since light scattering in the eye involves a low percentage of the light and has large angular spreading, contrast reduction due to straylight is limited, resulting in virtually absent acuity effects. (2) Basic optics: light scattering from the human donor eye lens is found to have virtually no effect in the centre of the point-spread-function, also for cataractous lenses, resulting in virtually absent acuity effects. (3) Statistical: literature data on straylight and visual acuity show a weak correlation for the important groups of normal ageing and cataract populations. The point-spread-function of the normal ageing and cataractous human eye is built upon two rather independent basic parts. Aberrations control the central peak. Light scattering controls the periphery from about 1° onwards. The way acuity and straylight are measured ensures no confounding between

  17. Effects of adhesive used as modeling liquid on the stability of the color and opacity of composites.

    PubMed

    Araujo, Fernanda Santos; Barros, Mellany Cristie Ramos; Santana, Márcia Luciana Carregosa; de Jesus Oliveira, Ludmila Smith; Silva, Paula Fernanda Damasceno; Lima, Giana da Silveira; Faria-E-Silva, André Luis

    2018-04-01

    This study evaluated the effects of adhesive type used as modeling liquid on the stability of the color and opacity of composites submitted to thermal cycling in staining solutions followed by a bleaching procedure. Thirty cylinder-shaped composite specimens (10 mm diameter × 1.5 mm thickness) were built using or not using (control) an adhesive (Adper Universal or Scotchbond Multipurpose) as the modeling liquid. After polishing procedures, the color and opacity were measured, and the specimens were submitted to 200 thermal cycles with 10 s of dwell time in baths of grape juice at 5°C, water at 37°C, and coffee at 55°C. Changes in opacity and color caused by the staining solutions were measured. Then, the specimens were bleached with 35% hydrogen peroxide for 45 minutes followed by color/opacity measurements. Data were analyzed by ANOVA and Tukey's test (α = 0.05). The use of modeling liquids did not affect the initial color and opacity of composite. Reduced changes to color (E 00  = 3.44) and opacity (+2.67%) were observed for specimens modeled using Adper Universal. Bleaching procedures reduced the color (E 00  = 1.9-3.8) and opacity (-2.3 to 3.1%) alterations caused by staining solutions but were unable to restore the values observed at baseline. The use of universal adhesive as modeling liquid significantly reduced the color and opacity changes caused by staining solutions, and the bleaching procedure partially re-established the opacity and color of the composites. This study evaluates whether using adhesive systems for modeling a composite affects the color and opacity changes caused by staining solutions followed by a bleaching procedure. The findings suggest that the use of a universal adhesive as modeling liquid can reduce the alterations in optical properties caused by staining solutions, and the application of high-concentrated hydrogen peroxide over the composite reduce the color changes without fully recover the initial color. © 2018

  18. [Magnetic resonance imaging study of effects of accommodation on human lens morphological characters].

    PubMed

    Zheng, Sui-lian; Zhang, Ai; Shi, Jian-jing; Zhou, Yun-xin

    2013-11-05

    To evaluate the effects of accommodation on lens morphological characters. From January 2011 to June 2011, magnetic resonance images of eyes were acquired from 30 subjects aged 20 to 24 years during accommodation and at rest. The optimal images were analyzed by Autocad 2010 to obtain the total lens cross-sectional area (CSA) and CSA of anterior and posterior portions of lens, anterior chamber depth, lens thickness, lens diameter, vitreous chamber depth and axial length during accommodation and at rest. Paired-t test was performed. The anterior curvature radius (mm), posterior curvature radius (mm), CSA of anterior portion (mm(2)), CSA of posterior portion (mm(2)), total lens CSA (mm(2)) was (8.7 ± 0.8), (6.2 ± 0.5), (7.5 ± 2.1), (12.0 ± 2.6), (20 ± 4) during relaxed accommodation; anterior curvature radius (mm), posterior curvature radius (mm), CSA of anterior portion (mm(2)), CSA of posterior portion (mm(2)), total lens CSA (mm(2)) was (7.1 ± 1.3), (5.6 ± 0.5), (14.7 ± 2.9), (12.2 ± 2.1) and (27 ± 4) during accommodation. The total lens CSA (t = -11.556, P < 0.01) and CSA of anterior portion (t = -15.653, P < 0.01) both increased in accommodative states. The CSA of posterior portion of lens (t = -0.437, P > 0.05) under a statistically independent accommodative state. There was significant difference in the anterior chamber depth (t = 4.366, P < 0.01), lens thickness (t = -5.456, P < 0.01) and lens diameter (t = 4.597, P < 0.01) in accommodative states. There were insignificant differences both in vitreous chamber depth (t = 0.428, P > 0.05) and axial length (t = 0.418, P > 0.05) under accommodative states. During accommodation, the anterior chamber depth decreases, lens thickness increases and diameter of lens decreases while anterior portions and total lens CSA increase. There are insignificant changes in posterior portions of lens CSA, vitreous chamber depth and axial length. The accommodative changes in CSA indicate that the anterior portion of lens

  19. Effect of chronic smoking on lens nucleus as assessed by Pentacam HR lens densitometry in young adults.

    PubMed

    Pekel, Gökhan; Cetin, Ebru Nevin; Acer, Semra; Yagci, Ramazan; Altintas, Seher; Ongun, Gülin Tugba

    2014-06-01

    To evaluate the effects of chronic tobacco smoking on lens nucleus by Pentacam HR lens densitometry (LD) in young adults. Prospective cross-sectional case series. Thirty subjects (23 M, 7 F) who were chronic cigarette smokers (≥10 cigarettes/day for at least 2 years) (group 1) and another 30 subjects (23 M, 7 F) who did not smoke (group 2), were included in this study. The patients were matched for age and sex between the groups. The exclusion criteria were any history of ocular surgery, any systemic disorders and any ocular diseases except for mild refractive disorders. Lens densitometry measurements were done with the Pentacam HR (Oculus, Wetzlar, Germany). The Schirmer test and pachymetry measurements were also performed. Mean age of the patients for both groups was 28.90 ± 8.20 years (range: 18-40 years). Mean lens densitometry (LD) measurements of Group 1 (chronic cigarette smoking group) were higher than those of Group 2 (control group) in all LD techniques; however only mean "peak" LD measurements showed a statistically significant difference between these two groups (Group 1: 8.67 ± 0.61, Group 2: 8.44 ± 0.70, p = 0.04). The mean Schirmer test value was 12.43 ± 5.60 mm in Group 1 and 13.00 ± 4.26 mm in Group 2 (p = 0.55). The mean central corneal thickness (CCT) value was 564.23 ± 34.61 µm in Group 1 and 550.47 ± 32.94 µm in Group 2 (p = 0.03). The Pentacam HR LD seems to be an important option for the evaluation of lens nucleus in young adults, because it gives objective and quantitative data. Although chronic smoking increases lens nucleus density in young adults, the effect is not statistically significant when compared with the control group.

  20. A Class I UV-blocking (senofilcon A) soft contact lens prevents UVA-induced yellow fluorescence and NADH loss in the rabbit lens nucleus in vivo.

    PubMed

    Giblin, Frank J; Lin, Li-Ren; Simpanya, Mukoma F; Leverenz, Victor R; Fick, Catherine E

    2012-09-01

    It is known that fluorescence, much of it caused by UVA light excitation, increases in the aging human lens, resulting in loss of sharp vision. This study used an in vivo animal model to investigate UVA-excited fluorescence in the rabbit lens, which contains a high level of the UVA chromophore NADH, existing both free and bound to λ-crystallin. Also, the ability of a Class I (senofilcon A) soft contact lens to protect against UVA-induced effects on the rabbit lens was tested. Rabbit eyes were irradiated with UVA light in vivo (100 mW/cm(2) on the cornea) for 1 h using monochromatic 365 nm light. Irradiation was conducted in the presence of either a senofilcon A contact lens, a minimally UV-absorbing lotrafilcon A contact lens, or no contact lens at all. Eyes irradiated without a contact lens showed blue 365 nm-excited fluorescence initially, but this changed to intense yellow fluorescence after 1 h. Isolated, previously irradiated lenses exhibited yellow fluorescence originating from the lens nucleus when viewed under 365 nm light, but showed normal blue fluorescence arising from the cortex. Previously irradiated lenses also exhibited a faint yellow color when observed under visible light. The senofilcon A contact lens protected completely against the UVA-induced effects on fluorescence and lens yellowing, whereas the lotrafilcon A lens showed no protection. The UVA-exposure also produced a 53% loss of total NADH (free plus bound) in the lens nucleus, with only a 13% drop in the anterior cortex. NADH loss in the nucleus was completely prevented with use of a senofilcon A contact lens, but no significant protection was observed with a lotrafilcon A lens. Overall, the senofilcon A lens provided an average of 67% protection against UVA-induced loss of four pyridine nucleotides in four different regions of the lens. HPLC analysis with fluorescence detection indicated a nearly six-fold increase in 365 nm-excited yellow fluorescence arising from lens nuclear

  1. Multimedia Visualizer: An Animated, Object-Based OPAC.

    ERIC Educational Resources Information Center

    Lee, Newton S.

    1991-01-01

    Describes the Multimedia Visualizer, an online public access catalog (OPAC) that uses animated visualizations to make it more user friendly. Pictures of the system are shown that illustrate the interactive objects that patrons can access, including card catalog drawers, librarian desks, and bookshelves; and access to multimedia items is described.…

  2. Exposure to subthreshold dose of UVR-B induces apoptosis in the lens epithelial cells and does not in the lens cortical fibre cells.

    PubMed

    Galichanin, Konstantin

    2017-12-01

    The aim of this study was to investigate in which part of the lens in vivo exposure to subthreshold dose of UVR-B radiation induces apoptosis. Twenty 6-week-old female albino Sprague-Dawley rats were exposed to subthreshold dose (1 kJ/m 2 ) of UVR-B unilaterally and killed at 120 hr after exposure. Lenses were enucleated and dissected on three regions: the lens epithelium, the cortex and the nucleus. The lens nucleus then was removed. Apoptosis markers p53 and caspase 3 were used to study apoptosis in the lens regions. qRT-PCR and Western blot were utilized to analyse the lenses. TP53 and CASP3 mRNA expressions are increased in exposed lenses, both in the lens epithelium and in the cortex regions, in relation to non-exposed lenses. Expression of p53 protein is increased in exposed lens epithelium in relation to non-exposed lens epithelium. Caspase 3 protein is expressed in exposed lens epithelial cells, while it is not expressed in non-exposed lens epithelial cells. p53 and caspase 3 proteins are not expressed in either exposed nor non-exposed lens fibre cells. Exposure to UVR-B increases mRNA transcription of apoptosis marker p53 in vivo in both regions of the lens and of apoptosis marker caspase 3 in the lens cortex. Exposure to UVR-B increases p53 and caspase 3 proteins expression just in the lens epithelium. In vivo exposure to subthreshold dose of UVR-B induces apoptosis in the lens epithelial cells and does not in the lens fibre cells. © 2017 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  3. Manual small incision cataract surgery (MSICS) with posterior chamber intraocular lens versus phacoemulsification with posterior chamber intraocular lens for age-related cataract.

    PubMed

    Riaz, Yasmin; de Silva, Samantha R; Evans, Jennifer R

    2013-10-10

    Age-related cataract is a major cause of blindness and visual morbidity worldwide. It is therefore important to establish the optimal technique of lens removal in cataract surgery. To compare manual small incision cataract surgery (MSICS) and phacoemulsification techniques. We searched CENTRAL (which contains the Cochrane Eyes and Vision Group Trials Register) (The Cochrane Library 2013, Issue 6), Ovid MEDLINE, Ovid MEDLINE In-Process and Other Non-Indexed Citations, Ovid MEDLINE Daily, Ovid OLDMEDLINE (January 1946 to July 2013), EMBASE (January 1980 to July 2013), Latin American and Caribbean Literature on Health Sciences (LILACS) (January 1982 to July 2013), Web of Science Conference Proceedings Citation Index - Science (CPCI-S) (January 1970 to July 2013), the metaRegister of Controlled Trials (mRCT) (www.controlled-trials.com), ClinicalTrials.gov (www.clinicaltrials.gov) and the WHO International Clinical Trials Registry Platform (ICTRP) (www.who.int/ictrp/search/en). We did not use any date or language restrictions in the electronic searches for trials. We last searched the electronic databases on 23 July 2013. We included randomised controlled trials (RCTs) for age-related cataract that compared MSICS and phacoemulsification. Two authors independently assessed all studies. We defined two primary outcomes: 'good functional vision' (presenting visual acuity of 6/12 or better) and 'poor visual outcome' (best corrected visual acuity of less than 6/60). We collected data on these outcomes at three and 12 months after surgery. Complications such as posterior capsule rupture rates and other intra- and postoperative complications were also assessed. In addition, we examined cost effectiveness of the two techniques. Where appropriate, we pooled data using a random-effects model. We included eight trials in this review with a total of 1708 participants. Trials were conducted in India, Nepal and South Africa. Follow-up ranged from one day to six months, but most trials

  4. Tamper asymmetry and its effect on transmission for x-ray driven opacity simulations

    NASA Astrophysics Data System (ADS)

    Morris, H. E.; Tregillis, I. L.; Hoffman, N. M.; Sherrill, M. E.; Fontes, C. J.; Marshall, A. J.; Urbatsch, T. J.; Bradley, P. A.

    2017-09-01

    This paper reports on synthetic transmission results from Lasnex [Zimmerman and Kruer, Comments Plasma Phys. 2, 51 (1975)] radiation-hydrodynamics simulations of opacity experiments carried out at Sandia National Laboratories' recently upgraded ZR facility. The focus is on experiments utilizing disk targets composed of a half-moon Fe/Mg mixture tamped on either end with 10-μm CH and an additional 35-μm beryllium tamper accessory on the end facing the spectrometer. Five x-ray sources with peak power ranging from 10 to 24 TW were used in the simulations to heat and backlight the opacity target. The dominant effect is that the beryllium behind the Fe/Mg mixture is denser and more opaque than the beryllium unshielded by metal during the times of greatest importance for the transmission measurement for all drives. This causes the simulated transmission to be lower than expected, and this is most pronounced for the case using the lowest drive power. While beryllium has a low opacity, its areal density is sufficiently high such that the expected reduction of the measured transmission is significant. This situation leads to an overestimate of iron opacity by 10%-215% for a photon energy range of 975-1775 eV for the 10-TW case. It is shown that if the tamper conditions are known, the transmission through each component of the target can be calculated and the resulting opacity can be corrected.

  5. Variable focus photographic lens without mechanical movements

    NASA Astrophysics Data System (ADS)

    Chen, Jiabi; Peng, Runling; Zhuang, Songlin

    2007-09-01

    A novel design of a zoom lens system without motorized movements is proposed. The lens system consists of a fixed lens and two double-liquid variable-focus lenses. The liquid lenses, made out of two immiscible liquids, are based on the principle of electrowetting: an effect controlling the wetting properties of a liquid on a solid by modifying the applied voltage at the solid-liquid interface. The structure and principle of the lens system are introduced in this paper. And detailed calculations and simulation examples are presented to predict how two liquid lenses are related to meet the basic requirements of zoom lenses.

  6. The molecular mechanisms underlying lens fiber elongation

    PubMed Central

    Audette, Dylan S.; Scheiblin, David A.; Duncan, Melinda K.

    2016-01-01

    Lens fiber cells are highly elongated cells with complex membrane morphologies that are critical for the transparency of the ocular lens. Investigations into the molecular mechanisms underlying lens fiber cell elongation were first reported in the 1960s, however, our understanding of the process is still poor nearly 50 years later. This review summarizes what is currently hypothesized about the regulation of lens fiber cell elongation along with the available experimental evidence, and how this information relates to what is known about the regulation of cell shape/elongation in other cell types, particularly neurons. PMID:27015931

  7. Castroviejo Lecture 2009: 40 years in search of the perfect contact lens.

    PubMed

    Cavanagh, H Dwight; Robertson, Danielle M; Petroll, W Matthew; Jester, James V

    2010-10-01

    To identify the pathophysiological changes produced by contact lens wear that predispose the cornea to infection and search for prospective modifiable risk factors that could reduce the incidence of this critical complication in millions of patients worldwide. Significant experimental and clinical publications are reviewed, and the results of ongoing studies are presented. Pseudomonas aeruginosa (PA) is the most common pathogen causing lens-related infectious keratitis over 3 decades. Contact lens wear can increase the risk of infection by increasing surface cell PA binding, thereby promoting invasion between broken tight junctions and initiating direct intracellular invasion mediated by lens-induced membrane lipid rafts. Prevention of upregulation of specific surface-binding receptors for PA with concomitant increase in infection risk is a zero damage game where independent interactions among lens type, mode of wear, oxygen transmissibility, polymer, and toxic effects of associated care solutions ideally should collectively produce no increased ability for PA to attach and/or to invade, thus minimizing the risk for lens-associated infections. The specific hypothesis tested is, "no increased epithelial surface damage... no increased PA binding or invasion... no increased risk for infection." Testing of this new paradigm has been performed in vitro and in animal and human clinical trials and correlated clinically with relative risk results from robust current epidemiological studies. Results to date clearly support the use of lens-related increases in PA binding (bench) as a noninvasive clinical predictor of risk for lens-related infection in subsequent large-scale population studies (bedside). Currently, results suggest that use of common commercial multipurpose lens care solutions with soft lenses may alone significantly increase infection risk by enhancing lens-related PA binding as compared with use of nonpreserved solutions (hydrogen peroxide). Clinical testing

  8. The Gaussian Plasma Lens in Astrophysics: Refraction

    NASA Astrophysics Data System (ADS)

    Clegg, Andrew W.; Fey, Alan L.; Lazio, T. Joseph W.

    1998-03-01

    We present the geometrical optics for refraction of a distant background radio source by an interstellar plasma lens, with specific application to a lens with a Gaussian profile of free-electron column density. The refractive properties of the lens are specified completely by a dimensionless parameter α, which is a function of the wavelength of observation, the free-electron column density through the lens, the lens-observer distance, and the diameter of the lens transverse to the line of sight. A lens passing between the observer and a background source, due to the relative motions of the observer, lens, and source, produces modulations in the light curve of the background source. Because plasma lenses are diverging, the light curve displays a minimum in the background source's flux density, formed when the lens is on-axis, surrounded by enhancements above the nominal (unlensed) flux density. The exact form of the light curve depends only upon the parameter α and the relative angular sizes of the source and lens as seen by the observer. Other effects due to lensing include the following: (1) the formation of caustic surfaces, upon which the apparent brightness of the background source becomes very large; (2) the possible creation of multiple images of the background source; and (3) angular position wander of the background source. If caustics are formed, the separation of the outer caustics can be used to constrain α, while the separation of the inner caustics can constrain the size of the lens. We apply our analysis to two sources, which have undergone extreme scattering events: (1) 0954+658, a source for which we can identify multiple caustics in its light curve, and (2) 1741-038, for which polarization observations were obtained during and after the scattering event. We find general agreement between modeled and observed light curves at 2.25 GHz, but poor agreement at 8.1 GHz. The discrepancies between the modeled and observed light curves may result from

  9. Physical and Chemical Processes Opacity Project: an Overview and Some Preliminary Results

    NASA Astrophysics Data System (ADS)

    Mendoza, C.

    1990-11-01

    RESUMEN. El Proyecto de la Opacidad es un esfuerzo internacional dedicado a calcular con precisi6n la gran cantidad de datos at6micos que se necesitan para estimar opacidades en los envolventes estelares. Describimos el panorama general del proyecto incluyendo aspectos astrofisicos, flsico-at6micos y computacionales. El volumen y calidad de los datos que se estan generando se puede apreciar en los resultados preliminares que se presentan. ABSTRACT The Opacity Project is an international effort dedicated to the calculation of the vast, accurate, atomic data required to estimate stellar envelope opacities. We give an overview of the project including astrophysical, atomic-physical and computational aspects. The volume and quality of the data which are being generated can be appreciated in the preliminary results that are presented. }% words: ATOMIC PROCESSES - OPACITIES - STARS-INThRIORS

  10. Longitudinal Andhra Pradesh Eye Disease Study: rationale, study design and research methodology.

    PubMed

    Khanna, Rohit C; Murthy, Gudlavalleti Vs; Marmamula, Srinivas; Mettla, Asha Latha; Giridhar, Pyda; Banerjee, Seema; Shekhar, Konegari; Chakrabarti, Subhabrata; Gilbert, Clare; Rao, Gullapalli N

    2016-03-01

    The rationale, objectives, study design and procedures for the longitudinal Andhra Pradesh Eye Disease Study are described. A longitudinal cohort study was carried out. Participants include surviving cohort from the rural component of Andhra Pradesh Eye Disease Study. During 1996-2000, Andhra Pradesh Eye Disease Survey was conducted in three rural (n = 7771) and one urban (n = 2522) areas (now called Andhra Pradesh Eye Disease Study 1). In 2009-2010, a feasibility exercise (Andhra Pradesh Eye Disease Study 2) for a longitudinal study (Andhra Pradesh Eye Disease Study 3) was undertaken in the rural clusters only, as urban clusters no longer existed. In Andhra Pradesh Eye Disease Study 3, a detailed interview will be carried out to collect data on sociodemographic factors, ocular and systemic history, risk factors, visual function, knowledge of eye diseases and barriers to accessing services. All participants will also undergo a comprehensive eye examination including photography of lens, optic disc and retina, Optic Coherence Tomography of the posterior segment, anthropometry, blood pressure and frailty measures. Measures include estimates of the incidence of visual impairment and age-related eye disease (lens opacities, glaucoma and age-related macular degeneration) and the progression of eye disease (lens opacities and myopia) and associated risk factors. Of the 7771 respondents examined in rural areas in Andhra Pradesh Eye Disease Study 1, 5447 (70.1%) participants were traced in Andhra Pradesh Eye Disease Study 2. These participants will be re-examined. Andhra Pradesh Eye Disease Study 3 will provide data on the incidence and progression of visual impairment and major eye diseases and their associated risk factors in India. The study will provide further evidence to aid planning eye care services. © 2015 Royal Australian and New Zealand College of Ophthalmologists.

  11. The status of intercellular junctions in established lens epithelial cell lines.

    PubMed

    Dave, Alpana; Craig, Jamie E; Sharma, Shiwani

    2012-01-01

    Cataract is the major cause of vision-related disability worldwide. Mutations in the crystallin genes are the most common known cause of inherited congenital cataract. Mutations in the genes associated with intercellular contacts, such as Nance-Horan Syndrome (NHS) and Ephrin type A receptor-2 (EPHA2), are other recognized causes of congenital cataract. The EPHA2 gene has been also associated with age-related cataract, suggesting that intercellular junctions are important in not only lens development, but also in maintaining lens transparency. The purpose of this study was to analyze the expression and localization of the key cell junction and cytoskeletal proteins, and of NHS and EPHA2, in established lens epithelial cell lines to determine their suitability as model epithelial systems for the functional investigation of genes involved in intercellular contacts and implicated in cataract. The expression and subcellular localization of occludin and zona occludens protein-1 (ZO-1), which are associated with tight junctions; E-cadherin, which is associated with adherence junctions; and the cytoskeletal actin were analyzed in monolayers of a human lens epithelial cell line (SRA 01/04) and a mouse lens epithelial cell line (αTN4). In addition, the expression and subcellular localization of the NHS and EPHA2 proteins were analyzed in these cell lines. Protein or mRNA expression was respectively determined by western blotting or reverse transcription-polymerase chain reaction (RT-PCR), and localization was determined by immunofluorescence labeling. Human SRA 01/04 and mouse αTN4 lens epithelial cells expressed either the proteins of interest or their encoding mRNA. Occludin, ZO-1, and NHS proteins localized to the cellular periphery, whereas E-cadherin, actin, and EPHA2 localized in the cytoplasm in these cell lines. The human SRA 01/04 and mouse αTN4 lens epithelial cells express the key junctional proteins. The localization patterns of these proteins suggest that

  12. Site specific oxidation of amino acid residues in rat lens γ-crystallin induced by low-dose γ-irradiation.

    PubMed

    Kim, Ingu; Saito, Takeshi; Fujii, Norihiko; Kanamoto, Takashi; Chatake, Toshiyuki; Fujii, Noriko

    2015-10-30

    Although cataracts are a well-known age-related disease, the mechanism of their formation is not well understood. It is currently thought that eye lens proteins become abnormally aggregated, initially causing clumping that scatters the light and interferes with focusing on the retina, and ultimately resulting in a cataract. The abnormal aggregation of lens proteins is considered to be triggered by various post-translational modifications, such as oxidation, deamidation, truncation and isomerization, that occur during the aging process. Such modifications, which are also generated by free radical and reactive oxygen species derived from γ-irradiation, decrease crystallin solubility and lens transparency, and ultimately lead to the development of a cataract. In this study, we irradiated young rat lenses with low-dose γ-rays and extracted the water-soluble and insoluble protein fractions. The water-soluble and water-insoluble lens proteins were digested with trypsin, and the resulting peptides were analyzed by LC-MS. Specific oxidation sites of methionine, cysteine and tryptophan in rat water-soluble and -insoluble γE and γF-crystallin were determined by one-shot analysis. The oxidation sites in rat γE and γF-crystallin resemble those previously identified in γC and γD-crystallin from human age-related cataracts. Our study on modifications of crystallins induced by ionizing irradiation may provide useful information relevant to human senile cataract formation. Copyright © 2015 Elsevier Inc. All rights reserved.

  13. First Iron Opacity Experiments on the National Ignition Facility

    NASA Astrophysics Data System (ADS)

    Perry, Theodore; Dodd, Evan; Cardenas, Tana; Devolder, Barbara; Flippo, Kirk; Johns, Heather; Kline, John; Sherrill, Manolo; Urbatsch, Todd; Heeter, Robert; Ahmed, Maryum; Emig, James; Iglesias, Carlos; Liedahl, Duane; London, Richard; Martin, Madison; Schneider, Marilyn; Thompson, Nathaniel; Wilson, Brian; Opachich, Yekaterina; King, James; Huffman, Eric; Knight, Russel; Bailey, James; Rochau, Gregory

    2017-10-01

    Iron opacity experiments on the Sandia National Laboratories Z machine have shown up to factors of two discrepancies between theory and experiment. To help resolve these discrepancies an experimental platform for doing comparable opacity experiments is being developed on the National Ignition Facility (NIF). Initial iron data has been taken at a temperature of 150 eV and an electron density of 6x1021/cm3, but higher temperatures and densities will be required to address the discrepancies that have been observed in the Z experiments. The plans to go to higher temperatures and densities and how to deal with current issues with instrumental backgrounds will be discussed. Performed under the auspices of USDOE LANL Contract DE-AC52-06NA25396.

  14. Preventive role of lens antioxidant defense mechanism against riboflavin-mediated sunlight damaging of lens crystallins.

    PubMed

    Anbaraki, Afrooz; Khoshaman, Kazem; Ghasemi, Younes; Yousefi, Reza

    2016-10-01

    The main components of sunlight reaching the eye lens are UVA and visible light exerting their photo-damaging effects indirectly by the aid of endogenous photosensitizer molecules such as riboflavin (RF). In this study, lens proteins solutions were incubated with RF and exposed to the sunlight. Then, gel mobility shift analysis and different spectroscopic assessments were applied to examine the structural damaging effects of solar radiation on these proteins. Exposure of lens proteins to direct sunlight, in the presence of RF, leads to marked structural crosslinking, oligomerization and proteolytic instability. These structural damages were also accompanied with reduction in the emission fluorescence of Trp and Tyr and appearance of a new absorption peak between 300 and 400nm which can be related to formation of new chromophores. Also, photo-oxidation of lens crystallins increases their oligomeric size distribution as examined by dynamic light scattering analysis. The above mentioned structural insults, as potential sources of sunlight-induced senile cataract and blindness, were significantly attenuated in the presence of ascorbic acid and glutathione which are two important components of lens antioxidant defense system. Therefore, the powerful antioxidant defense mechanism of eye lens is an important barrier against molecular photo-damaging effects of solar radiations during the life span. Copyright © 2016 Elsevier B.V. All rights reserved.

  15. Generation of dark hollow beam by focusing a sine-Gaussian beam using a cylindrical lens and a focusing lens

    NASA Astrophysics Data System (ADS)

    Tang, Huiqin; Zhu, Kaicheng

    2013-12-01

    Based on the generalized Huygens-Fresnel diffraction integral, a closed-form propagation equation related to sine-Gaussian beams through a cylindrical lens and a focusing lens is derived and illustrated with numerical methods. It is found that a sine-Gaussian beam through such a system may be converted into a dark hollow beam (DHB) with topological charge index one and its bright enclosure is approximately an elongated ellipse with very high ellipticity. Moreover, the parameter values at which the DHBs have perfect intensity patterns are designed. The optimal relative orientation between the dislocation line of the input sine-Gaussian beam and the axial orientation of the cylindrical lens is specified. And the ellipticity of the elliptical DHBs is mainly defined by the focal length of the cylindrical lens and the Fresnel number of the optical system.

  16. Conceptual design of initial opacity experiments on the national ignition facility

    NASA Astrophysics Data System (ADS)

    Heeter, R. F.; Bailey, J. E.; Craxton, R. S.; Devolder, B. G.; Dodd, E. S.; Garcia, E. M.; Huffman, E. J.; Iglesias, C. A.; King, J. A.; Kline, J. L.; Liedahl, D. A.; McKenty, P. W.; Opachich, Y. P.; Rochau, G. A.; Ross, P. W.; Schneider, M. B.; Sherrill, M. E.; Wilson, B. G.; Zhang, R.; Perry, T. S.

    2017-02-01

    Accurate models of X-ray absorption and re-emission in partly stripped ions are necessary to calculate the structure of stars, the performance of hohlraums for inertial confinement fusion and many other systems in high-energy-density plasma physics. Despite theoretical progress, a persistent discrepancy exists with recent experiments at the Sandia Z facility studying iron in conditions characteristic of the solar radiative-convective transition region. The increased iron opacity measured at Z could help resolve a longstanding issue with the standard solar model, but requires a radical departure for opacity theory. To replicate the Z measurements, an opacity experiment has been designed for the National Facility (NIF). The design uses established techniques scaled to NIF. A laser-heated hohlraum will produce X-ray-heated uniform iron plasmas in local thermodynamic equilibrium (LTE) at temperatures eV and electron densities 21~\\text{cm}-3$ . The iron will be probed using continuum X-rays emitted in a ps, diameter source from a 2 mm diameter polystyrene (CH) capsule implosion. In this design, of the NIF beams deliver 500 kJ to the mm diameter hohlraum, and the remaining directly drive the CH capsule with 200 kJ. Calculations indicate this capsule backlighter should outshine the iron sample, delivering a point-projection transmission opacity measurement to a time-integrated X-ray spectrometer viewing down the hohlraum axis. Preliminary experiments to develop the backlighter and hohlraum are underway, informing simulated measurements to guide the final design.

  17. Corneal and crystalline lens dimensions before and after myopia onset.

    PubMed

    Mutti, Donald O; Mitchell, G Lynn; Sinnott, Loraine T; Jones-Jordan, Lisa A; Moeschberger, Melvin L; Cotter, Susan A; Kleinstein, Robert N; Manny, Ruth E; Twelker, J Daniel; Zadnik, Karla

    2012-03-01

    To describe corneal and crystalline lens dimensions before, during, and after myopia onset compared with age-matched emmetropic values. Subjects were 732 children aged 6 to 14 years who became myopic and 596 emmetropic children participating between 1989 and 2007 in the Collaborative Longitudinal Evaluation of Ethnicity and Refractive Error Study. Refractive error was measured using cycloplegic autorefraction, corneal power using a hand-held autokeratometer, crystalline lens parameters using video-based phakometry, and vitreous chamber depth (VCD) using A-scan ultrasonography. Corneal and crystalline lens parameters in children who became myopic were compared with age-, gender-, and ethnicity-matched model estimates of emmetrope values annually from 5 years before through 5 years after the onset of myopia. The comparison was made without and then with statistical adjustment of emmetrope component values to compensate for the effects of longer VCDs in children who became myopic. Before myopia onset, the crystalline lens thinned, flattened, and lost power at similar rates for emmetropes and children who became myopic. The crystalline lens stopped thinning, flattening, and losing power within ±1 year of onset in children who became myopic compared with emmetropes statistically adjusted to match the longer VCDs of children who became myopic. In contrast, the cornea was only slightly steeper in children who became myopic compared with emmetropes (<0.25 D) and underwent little change across visits. Myopia onset is characterized by an abrupt loss of compensatory changes in the crystalline lens that continue in emmetropes throughout childhood axial elongation. The mechanism responsible for this decoupling remains speculative but might include restricted equatorial growth from internal mechanical factors.

  18. Corneal and Crystalline Lens Dimensions Before and After Myopia Onset

    PubMed Central

    Mutti, Donald O.; Mitchell, G. Lynn; Sinnott, Loraine T.; Jones-Jordan, Lisa A.; Moeschberger, Melvin L.; Cotter, Susan A.; Kleinstein, Robert N.; Manny, Ruth E.; Twelker, J. Daniel; Zadnik, Karla

    2011-01-01

    Purpose To describe corneal and crystalline lens dimensions before, during, and after myopia onset compared to age-matched emmetropic values. Methods Subjects were 732 children 6 to 14 years of age who became myopic and 596 emmetropic children participating between 1989 and 2007 in the Collaborative Longitudinal Evaluation of Ethnicity and Refractive Error Study. Refractive error was measured using cycloplegic autorefraction, corneal power using a hand-held autokeratometer, crystalline lens parameters using video-based phakometry, and vitreous chamber depth (VCD) using A-scan ultrasonography. Corneal and crystalline lens parameters in children who became myopic were compared to age-, gender-, and ethnicity-matched model estimates of emmetrope values annually from 5 years before through 5 years after the onset of myopia. The comparison was made without, then with statistical adjustment of emmetrope component values to compensate for the effects of longer VCDs in children who became myopic. Results Before myopia onset, the crystalline lens thinned, flattened, and lost power at similar rates for emmetropes and children who became myopic. The crystalline lens stopped thinning, flattening, and losing power within ±1 year of onset in children who became myopic compared to emmetropes statistically adjusted to match the longer vitreous chamber depths of children who became myopic. In contrast, the cornea was only slightly steeper in children who became myopic compared to emmetropes (<0.25 D) and underwent little change across visits. Conclusions Myopia onset is characterized by an abrupt loss of compensatory changes in the crystalline lens that continue in emmetropes throughout childhood axial elongation. The mechanism responsible for this decoupling remains speculative, but might include restricted equatorial growth from internal mechanical factors. PMID:22227914

  19. MAFAGS-OS: New opacity sampling model atmospheres for A, F and G stars. I. The model and the solar flux

    NASA Astrophysics Data System (ADS)

    Grupp, F.

    2004-06-01

    We present a new opacity sampling model atmosphere code, named MAFAGS-OS. This code, designed for stars reaching from A0 down to G9 on a solar and metal poor main sequence and up to an evolutionary stage represented by the turnoff is introduced in its basic input physics and modelling techniques. Fe I bound-free cross-sections of \\citet{BAUTISTA97} are used and convection is treated according to \\citet{canuto91}. An αcm-parameter for the efficiency of convection of 0.82 is used as determined by \\citet{BERNKOPF98} from stellar evolution requirements. Within the process of opacity sampling, special attention is drawn to the matter of line selection. We show that a selection criterion, in which lines are chosen by their opacity weighted relative to the continuous background opacity, is useful and valid. The solar model calculated using this new code is shown to fit the measured solar flux distribution. It is also tested against the measured solar colours and leads to U-B=0.21 and B-V=0.64, in good agreement with observation. Comparison with measured centre-to-limb continuum data show only small improvement with respect to opacity-sampling type model atmospheres. This is the first of a series of 2 papers. Paper II will deal with the matter of temperature determination using Balmer lines and the infrared-flux method; furthermore it will present three ``standard'' stars analysed using this new model.

  20. The prevalence of enamel opacities in permanent teeth of 11-12 year-old school children in Kuala Lumpur, Malaysia.

    PubMed

    Yusoff, N; Jaafar, N; Razak, I A; Chew, Y Y; Ismail, N; Bulgiba, A M

    2008-03-01

    To determine the prevalence, distribution, severity and treatment need of enamel opacities among 11-12 year-old school children in a fluoridated urban community. A cross-sectional descriptive survey of enamel opacities in 11-12 year-old schoolchildren. A questionnaire survey and a clinical examination of erupted teeth using the Modified DDE Index was conducted on schoolchildren in randomly selected schools. 957 schoolchildren from government schools in Kuala Lumpur comprising the three major ethnic groups of Malay, Chinese and Indian children. The severity of enamel opacities was assessed by the extent of buccal surface involvement. Normative treatment need was based on severity of opacities. Enamel opacities were found in 90.7% of subjects and 47.2% of teeth. Malays have the highest prevalence with Chinese the least. Although ethnic differences is statistically significant (p < 0.01), the differences in prevalence between ethnicity is small. The most common type of defect was "diffuse opacities" (88.6% of subjects). Most subjects (70%) showed bilateral distribution of diffuse opacities indicating a systemic disturbance. Posterior teeth were twice more commonly affected (p < 0.05). The majority of opacities in anterior teeth (66.7%) were minor, involving less than 1/3 of the labial surface. Only 0.6% of the whole sample required some form of aesthetic intervention. Despite the high prevalence of enamel opacities, the degree of severity is very mild with only minimal aesthetic and public health concern.

  1. Bioinspired adaptive gradient refractive index distribution lens

    NASA Astrophysics Data System (ADS)

    Yin, Kezhen; Lai, Chuan-Yar; Wang, Jia; Ji, Shanzuo; Aldridge, James; Feng, Jingxing; Olah, Andrew; Baer, Eric; Ponting, Michael

    2018-02-01

    Inspired by the soft, deformable human eye lens, a synthetic polymer gradient refractive index distribution (GRIN) lens with an adaptive geometry and focal power has been demonstrated via multilayer coextrusion and thermoforming of nanolayered elastomeric polymer films. A set of 30 polymer nanolayered films comprised of two thermoplastic polyurethanes having a refractive index difference of 0.05 were coextruded via forced-assembly technique. The set of 30 nanolayered polymer films exhibited transmission near 90% with each film varying in refractive index by 0.0017. An adaptive GRIN lens was fabricated from a laminated stack of the variable refractive index films with a 0.05 spherical GRIN. This lens was subsequently deformed by mechanical ring compression of the lens. Variation in the optical properties of the deformable GRIN lens was determined, including 20% variation in focal length and reduced spherical aberration. These properties were measured and compared to simulated results by placido-cone topography and ANSYS methods. The demonstration of a solid-state, dynamic focal length, GRIN lens with improved aberration correction was discussed relative to the potential future use in implantable devices.

  2. Sharing of secondary electrons by in-lens and out-lens detector in low-voltage scanning electron microscope equipped with immersion lens.

    PubMed

    Kumagai, Kazuhiro; Sekiguchi, Takashi

    2009-03-01

    To understand secondary electron (SE) image formation with in-lens and out-lens detector in low-voltage scanning electron microscopy (LV-SEM), we have evaluated SE signals of an in-lens and an out-lens detector in LV-SEM. From the energy distribution spectra of SEs with various boosting voltages of the immersion lens system, we revealed that the electrostatic field of the immersion lens mainly collects electrons with energy lower than 40eV, acting as a low-pass filter. This effect is also observed as a contrast change in LV-SEM images taken by in-lens and out-lens detectors.

  3. 77 FR 8160 - Quality Assurance Requirements for Continuous Opacity Monitoring Systems at Stationary Sources

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-02-14

    ..., glass windows (uncoated or anti-reflection coated, but with no curvature), lenses with mounts where such... requirements must I meet if I use a substitute opacity monitor? In the event that your certified opacity... the above in the maintenance log or in other appropriate permanently maintained records. 10.7 When do...

  4. LENS: Prototyping Program

    NASA Astrophysics Data System (ADS)

    Rountree, S. Derek

    2013-04-01

    The Low-Energy Neutrino Spectrometer (LENS) prototyping program is broken into two phases. The first of these is μLENS, a small prototype to study the light transmission in the as built LENS scintillation lattice--- a novel detector method of high segmentation in a large liquid scintillation detector. The μLENS prototype is currently deployed and taking data at the Kimballton Underground Research Facility (KURF) near Virginia Tech. I will discuss the Scintillation Lattice construction methods and schemes of the μLENS program for running with minimal channels instrumented to date ˜41 compared to full coverage 216). The second phase of prototyping is the miniLENS detector for which construction is under way. I will discuss the overall design from the miniLENS Scintillation Lattice to the shielding.

  5. Laboratory Measurements of Sulfuric Acid Vapor Opacity at Millimeter Wavelengths Under Venus Conditions

    NASA Astrophysics Data System (ADS)

    Akins, Alexander Brooks; Steffes, Paul G.

    2017-10-01

    Radio astronomical observations of the lower-cloud and sub-cloud regions of the Venusian atmosphere at millimeter wavelengths can provide insight into the nature of the sub-cloud sulfur chemistry. Previous observations (de Pater et al., Icarus 90, 1991 and Sagawa, J. Natl. Inst. of Inf. And Comm. Tech. 55, 2008) indicate substantial variations in Venus disc brightness at millimeter wavelengths, likely due to variations in SO2 and H2SO4 vapor abundances. Although previous measurements of H2SO4 vapor opacity provide accurate information at centimeter wavelengths (Kolodner and Steffes, Icarus 132, 1998), extrapolation to millimeter wavelength observations is speculative. A Fabry-Perot open resonator with a quality factor in excess of 15,000 has been designed to measure the opacity of H2SO4 vapor in a CO2 atmosphere under Venus temperature and pressure conditions below the clouds. The resonator system has been designed using corrosion-resistant materials to ensure data integrity. Opacity measurements made with this system target the 2-4 millimeter wavelength range, applicable to recent Atacama Large Millimeter Array observations of Venus. Initial laboratory results for H2SO4 vapor opacity will be presented, and the implications of these results for pressure broadened opacity formalisms will be discussed. In addition to radio astronomical observations, these results of these measurements can aid in the interpretation of radiometer and radio occultation measurements from future Venus missions, such as the Venera D orbiter. This work is supported by the NASA Solar System Workings Program under grant NNX17AB19G.

  6. Quantitative determination of radio-opacity: equivalence of digital and film X-ray systems.

    PubMed

    Nomoto, R; Mishima, A; Kobayashi, K; McCabe, J F; Darvell, B W; Watts, D C; Momoi, Y; Hirano, S

    2008-01-01

    To evaluate the equivalence of a digital X-ray system (DenOptix) to conventional X-ray film in terms of the measured radio-opacity of known filled-resin materials and the suitability of attenuation coefficient for radio-opacity determination. Discs of five thicknesses (0.5-2.5mm) and step-wedges of each of three composite materials of nominal aluminum-equivalence of 50%, 200% and 450% were used. X-ray images of a set of discs (or step-wedge), an aluminum step-wedge, and a lead block were taken at 65 kV and 10 mA at a focus-film distance of 400 mm for 0.15s and 1.6s using an X-ray film or imaging plate. Radio-opacity was determined as equivalent aluminum thickness and attenuation coefficient. The logarithm of the individual optical density or gray scale value, corrected for background, was plotted against thickness, and the attenuation coefficient determined from the slope. The method of ISO 4049 was used for equivalent aluminum thickness. The equivalent aluminum thickness method is not suitable for materials of low radio-opacity, while the attenuation coefficient method could be used for all without difficulty. The digital system gave attenuation coefficients of greater precision than did film, but the use of automatic gain control (AGC) distorted the outcome unusably. Attenuation coefficient is a more precise and generally applicable approach to the determination of radio-opacity. The digital system was equivalent to film but with less noise. The use of AGC is inappropriate for such determinations.

  7. Prototyping for LENS

    NASA Astrophysics Data System (ADS)

    Rasco, B. C.

    2012-03-01

    The Low-Energy Neutrino Spectroscopy (LENS) experiment will precisely measure the energy spectrum of low-energy solar neutrinos via charged-current neutrino reactions on indium. The LENS detector concept applies indium-loaded scintillator in an optically-segmented lattice geometry to achieve precise time and spatial resolution with unprecedented sensitivity for low-energy neutrino events. The LENS collaboration is currently developing prototypes that aim to demonstrate the performance and selectivity of the technology and to benchmark Monte Carlo simulations that will guide scaling to the full LENS instrument. Currently a 120 liter prototype, microLENS, is operating with pure scintillator (no indium loading) in the Kimballton Underground Research Facility (KURF). We will present results from initial measurements with microLENS and plans for a 400 liter prototype, miniLENS, using indium loaded scintillator that will be installed this summer.

  8. First-principles opacity table of warm dense deuterium for inertial-confinement-fusion applications.

    PubMed

    Hu, S X; Collins, L A; Goncharov, V N; Boehly, T R; Epstein, R; McCrory, R L; Skupsky, S

    2014-09-01

    Accurate knowledge of the optical properties of a warm dense deuterium-tritium (DT) mixture is important for reliable design of inertial confinement fusion (ICF) implosions using radiation-hydrodynamics simulations. The opacity of a warm dense DT shell essentially determines how much radiation from hot coronal plasmas can be deposited in the DT fuel of an imploding capsule. Even for the simplest species of hydrogen, the accurate calculation of their opacities remains a challenge in the warm-dense matter regime because strong-coupling and quantum effects play an important role in such plasmas. With quantum-molecular-dynamics (QMD) simulations, we have derived a first-principles opacity table (FPOT) of deuterium (and the DT mixture by mass scaling) for a wide range of densities from ρ(D)=0.5 to 673.518g/cm(3) and temperatures from T=5000K up to the Fermi temperature T(F) for each density. Compared with results from the astrophysics opacity table (AOT) currently used in our hydrocodes, the FPOT of deuterium from our QMD calculations has shown a significant increase in opacity for strongly coupled and degenerate plasma conditions by a factor of 3-100 in the ICF-relevant photon-energy range. As conditions approach those of classical plasma, the opacity from the FPOT converges to the corresponding values of the AOT. By implementing the FPOT of deuterium and the DT mixture into our hydrocodes, we have performed radiation-hydrodynamics simulations for low-adiabat cryogenic DT implosions on the OMEGA laser and for direct-drive-ignition designs for the National Ignition Facility. The simulation results using the FPOT show that the target performance (in terms of neutron yield and energy gain) could vary from ∼10% up to a factor of ∼2 depending on the adiabat of the imploding DT capsule; the lower the adiabat, the more variation is seen in the prediction of target performance when compared to the AOT modeling.

  9. Refractive index measurement of the mouse crystalline lens using optical coherence tomography.

    PubMed

    Chakraborty, Ranjay; Lacy, Kip D; Tan, Christopher C; Park, Han Na; Pardue, Machelle T

    2014-08-01

    In recent years, there has been a growing interest for using mouse models in refractive development and myopia research. The crystalline lens is a critical optical component of the mouse eye that occupies greater than 50% of the ocular space, and significant increases in thickness with age. However, changes in refractive index of the mouse crystalline lens are less known. In this study, we examined the changes in thickness and refractive index of the mouse crystalline lens for two different strains, wild-type (WT) and a nyx mutant (nob) over the course of normal visual development or after form deprivation. Refractive index and lens thickness measurements were made on ex vivo lenses using spectral domain optical coherence tomography (SD-OCT). Comparison of refractive index measurements on 5 standard ball lenses using the SD-OCT and their known refractive indices (manufacturer provided) indicated good precision (intra-class correlation coefficient, 0.998 and Bland-Altman coefficient of repeatability, 0.116) of the SD-OCT to calculate mouse lens refractive index ex vivo. During normal visual development, lens thickness increased significantly with age for three different cohorts of mice, aged 4 (average thickness from both eyes; WT: 1.78 ± 0.03, nob: 1.79 ± 0.08 mm), 10 (WT: 2.02 ± 0.05, nob: 2.01 ± 0.04 mm) and 16 weeks (WT: 2.12 ± 0.06, nob: 2.09 ± 0.06 mm, p < 0.001). Lens thickness was not significantly different between the two strains at any age (p = 0.557). For mice with normal vision, refractive index for isolated crystalline lenses in nob mice was significantly greater than WT mice (mean for all ages; WT: 1.42 ± 0.01, nob: 1.44 ± 0.001, p < 0.001). After 4 weeks of form deprivation to the right eye using a skull-mounted goggling apparatus, a thinning of the crystalline lens was observed in both right and left eyes of goggled animals compared to their naïve controls (average from both the right and the left eye) for both

  10. Contact lens-related dry eye and ocular surface changes with mapping technique in long-term soft silicone hydrogel contact lens wearers.

    PubMed

    Sengor, Tomris; Aydin Kurna, Sevda; Ozbay, Nurver; Ertek, Semahat; Aki, Suat; Altun, Ahmet

    2012-01-01

    To evaluate ocular surface changes in long-term silicone hydrogel contact lens wearers. Thirty patients were included in this study. Twenty patients (40 eyes) using contact lenses constituted group 1 and 10 (20 eyes) volunteers constituted group 2. The duration of average contact lens usage was 7.74 ± 3.3 years. Ocular surface was evaluated by surface staining, tear film break-up time (TBUT), Schirmer I test, and conjunctival impression cytology with color-coded mapping technique and by the Ocular Surface Disease Index (OSDI). The mean break-up time was lower and staining scores were higher in group 1 (p<0.001) but Schirmer values were not significantly different from group 2 (p>0.05). The mean OSDI score was 34.59 ± 11.93 to 19.28 ± 6.7 in group 1 and 2. Increased metaplastic predominant changes of grade II and III were observed in the interpalpebral and perilimbal areas in group 1. Significant correlations were observed in TBUT, cornea staining, and grade II to grade III metaplasia ratios between duration of the lens usage and contact lens wear time in a day. Silicone hydrogel lenses produce significant changes on tear film and impression cytology of the ocular surface in long-term use.

  11. Growth of the eye lens: II. Allometric studies

    PubMed Central

    2014-01-01

    Purpose The purpose of this study was to examine the ontogeny and phylogeny of lens growth in a variety of species using allometry. Methods Data on the accumulation of wet and/or dry lens weight as a function of bodyweight were obtained for 40 species and subjected to allometric analysis to examine ontogenic growth and compaction. Allometric analysis was also used to compare the maximum adult lens weights for 147 species with the maximum adult bodyweight and to compare lens volumes calculated from wet and dry weights with eye volumes calculated from axial length. Results Linear allometric relationships were obtained for the comparison of ontogenic lens and bodyweight accumulation. The body mass exponent (BME) decreased with increasing animal size from around 1.0 in small rodents to 0.4 in large ungulates for both wet and dry weights. Compaction constants for the ontogenic growth ranged from 1.00 in birds and reptiles up to 1.30 in mammals. Allometric comparison of maximum lens wet and dry weights with maximum bodyweights also yielded linear plots with a BME of 0.504 for all warm blooded species except primates which had a BME of 0.25. When lens volumes were compared with eye volumes, all species yielded a scaling constant of 0.75 but the proportionality constants for primates and birds were lower. Conclusions Ontogenic lens growth is fastest, relative to body growth, in small animals and slowest in large animals. Fiber cell compaction takes place throughout life in most species, but not in birds and reptiles. Maximum adult lens size scales with eye size with the same exponent in all species, but birds and primates have smaller lenses relative to eye size than other species. Optical properties of the lens are generated through the combination of variations in the rate of growth, rate of compaction, shape and size. PMID:24715759

  12. Growth of the eye lens: II. Allometric studies.

    PubMed

    Augusteyn, Robert C

    2014-01-01

    The purpose of this study was to examine the ontogeny and phylogeny of lens growth in a variety of species using allometry. Data on the accumulation of wet and/or dry lens weight as a function of bodyweight were obtained for 40 species and subjected to allometric analysis to examine ontogenic growth and compaction. Allometric analysis was also used to compare the maximum adult lens weights for 147 species with the maximum adult bodyweight and to compare lens volumes calculated from wet and dry weights with eye volumes calculated from axial length. Linear allometric relationships were obtained for the comparison of ontogenic lens and bodyweight accumulation. The body mass exponent (BME) decreased with increasing animal size from around 1.0 in small rodents to 0.4 in large ungulates for both wet and dry weights. Compaction constants for the ontogenic growth ranged from 1.00 in birds and reptiles up to 1.30 in mammals. Allometric comparison of maximum lens wet and dry weights with maximum bodyweights also yielded linear plots with a BME of 0.504 for all warm blooded species except primates which had a BME of 0.25. When lens volumes were compared with eye volumes, all species yielded a scaling constant of 0.75 but the proportionality constants for primates and birds were lower. Ontogenic lens growth is fastest, relative to body growth, in small animals and slowest in large animals. Fiber cell compaction takes place throughout life in most species, but not in birds and reptiles. Maximum adult lens size scales with eye size with the same exponent in all species, but birds and primates have smaller lenses relative to eye size than other species. Optical properties of the lens are generated through the combination of variations in the rate of growth, rate of compaction, shape and size.

  13. The use of films to simulate age-related declines in yellow vision.

    PubMed

    Yoshida, C A; Sakuraba, S

    1996-06-01

    One of characteristics of normal age-related vision losses depends on yellow-intensity in the lens of the eye. (1) We investigated discrimination between seven intensities of yellow in 303 elderly people aged from late 60s to early 90s. The results demonstrated that the failures of vision increase with age, and the losses depend on yellow intensity. (2) We got a yellow index (YI) from different Y-intensity color charts used in (I) above, covering 12 kinds of marketable yellow films, and selected two kinds of films which match (YI) original color charts, corresponding to 53% or 89% of Y intensity. (3) Finally, we judged that all of these colors' xy-chromaticities with or without the two films, were exactly on the unique-yellow line in the diagram, which means a pure yellow, not mixed. (4) Then, these two films could simulate each of the mid-level or high-level Y intensity, respectively, in age-related vision. (5) We analyzed changes of all kinds of colors (220) in xy-chromaticity diagrams and obtained mean changing distances from every original chromatogram compared to the others. These data would be useful for architects or designers to design cities or buildings for use by the elderly.

  14. Numerical investigations of potential systematic uncertainties in iron opacity measurements at solar interior temperatures

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nagayama, T.; Bailey, J. E.; Loisel, G. P.

    Iron opacity calculations presently disagree with measurements at an electron temperature of ~180–195 eV and an electron density of (2–4)×10 22cm –3, conditions similar to those at the base of the solar convection zone. The measurements use x rays to volumetrically heat a thin iron sample that is tamped with low-Z materials. The opacity is inferred from spectrally resolved x-ray transmission measurements. Plasma self-emission, tamper attenuation, and temporal and spatial gradients can all potentially cause systematic errors in the measured opacity spectra. In this article we quantitatively evaluate these potential errors with numerical investigations. The analysis exploits computer simulations thatmore » were previously found to reproduce the experimentally measured plasma conditions. The simulations, combined with a spectral synthesis model, enable evaluations of individual and combined potential errors in order to estimate their potential effects on the opacity measurement. Lastly, the results show that the errors considered here do not account for the previously observed model-data discrepancies.« less

  15. Numerical investigations of potential systematic uncertainties in iron opacity measurements at solar interior temperatures

    DOE PAGES

    Nagayama, T.; Bailey, J. E.; Loisel, G. P.; ...

    2017-06-26

    Iron opacity calculations presently disagree with measurements at an electron temperature of ~180–195 eV and an electron density of (2–4)×10 22cm –3, conditions similar to those at the base of the solar convection zone. The measurements use x rays to volumetrically heat a thin iron sample that is tamped with low-Z materials. The opacity is inferred from spectrally resolved x-ray transmission measurements. Plasma self-emission, tamper attenuation, and temporal and spatial gradients can all potentially cause systematic errors in the measured opacity spectra. In this article we quantitatively evaluate these potential errors with numerical investigations. The analysis exploits computer simulations thatmore » were previously found to reproduce the experimentally measured plasma conditions. The simulations, combined with a spectral synthesis model, enable evaluations of individual and combined potential errors in order to estimate their potential effects on the opacity measurement. Lastly, the results show that the errors considered here do not account for the previously observed model-data discrepancies.« less

  16. The Correlation between Daily Lens Wear Duration and Dry Eye Syndrome.

    PubMed

    Lubis, Rodiah Rahmawaty; Gultom, Monica Tumiar Hanna

    2018-05-20

    To analyze the correlation between the daily lens wear duration and dry eye syndrome. This study was an analytic cross sectional study using consecutive sampling conducted among the students in Economy and Bussiness Faculty and Faculty of Humanities in University of Sumatera Utara aged between 17 to 23 that wore contact lens continously for at least a year and 5 days a week. The symptoms were assessed using Contact Lens Dry Eye Questionnaire-8 (CLDEQ-8) and interview about their contact lens comfort; eye drops usage, contact lens washing habit, daily circumstances, places to buy contact lens and personal experince in wearing contact lens. The questionnaire was completed by 53 students. All of them were female and wore softlens wearers. The mean duration of daily wear was 8.19 ± 2.20 hours. The most common symptom experienced was dry eye and the least symptom experienced was removing lens. The most frequent symptom experienced was closing eyes and the least frequent symptom experienced was removing lenses. This study used Exact Test as analysis statistic method. The result was p > 0.05 which means there is no correlation between daily lens wear duration and dry eye syndrome. This study showed that dry eye syndrome was not correlated with daily lens wear duration, but affected by many factors such as contact lens, lens care solution, eye drops usage and environment.

  17. Increased resistance of contact lens related bacterial biofilms to antimicrobial activity of soft contact lens care solutions

    PubMed Central

    Szczotka-Flynn, Loretta B.; Imamura, Yoshifumi; Chandra, Jyotsna; Yu, Changping; Mukherjee, Pranab K.; Pearlman, Eric; Ghannoum, Mahmoud A.

    2014-01-01

    PURPOSE To determine if clinical and reference strains of Pseudomonas aeruginosa, Serratia marcescens, and Staphylococcus aureus form biofilms on silicone hydrogel contact lenses, and ascertain antimicrobial activities of contact lens care solutions. METHODS Clinical and American Type Culture Collection (ATCC) reference strains of Pseudomonas aeruginosa, Serratia marcescens, and Staphylococcus aureus were incubated with lotrafilcon A lenses under conditions that facilitate biofilm formation. Biofilms were quantified by quantitative culturing (colony forming units, CFUs), and gross morphology and architecture were evaluated using scanning electron microscopy (SEM) and confocal microscopy. Susceptibilities of the planktonic and biofilm growth phases of the bacteria to five common multipurpose contact lens care solutions and one hydrogen peroxide care solution were assessed. RESULTS P. aeruginosa, S. marcescens, and S. aureus reference and clinical strains formed biofilms on lotrafilcon A silicone hydrogel contact lenses, as dense networks of cells arranged in multiple layers with visible extracellular matrix. The biofilms were resistant to commonly used biguanide preserved multipurpose care solutions. P. aeruginosa and S. aureus biofilms were susceptible to a hydrogen peroxide and a polyquaternium preserved care solution, whereas S. marcescens biofilm was resistant to a polyquaternium preserved care solution but susceptible to hydrogen peroxide disinfection. In contrast, the planktonic forms were always susceptible. CONCLUSIONS P. aeruginosa, S. marcescens, and S. aureus form biofilms on lotrafilcon A contact lenses, which in contrast to planktonic cells, are resistant to the antimicrobial activity of several soft contact lens care products. PMID:19654521

  18. Increased numbers of Demodex in contact lens wearers.

    PubMed

    Jalbert, Isabelle; Rejab, Shazana

    2015-06-01

    The aim of this study was to determine if Demodex infestation is more frequent in contact lens wearers than in nonwearers. Secondary aims were to evaluate the effects of Demodex on the ocular surface (symptoms and signs) and to evaluate the ability of confocal laser scanning microscopy to detect and quantify the Demodex infestation compared with the conventional light microscopic technique. Forty Asian female participants (20 nonwearers, 20 lens wearers) with a mean (± SD) age of 27 (± 9) years were recruited. Ocular comfort scores (Ocular Surface Disease Index, Ocular Comfort Index, and Dry Eye Questionnaire), vital staining (corneal, conjunctival, and lid wiper), tear osmolarity, tear breakup time, and meibomian gland evaluation were evaluated. Demodex was detected using in vivo confocal microscopy and conventional light microscopy. The number of Demodex was higher in lens wearers than in nonwearers (7.6 [± 5.8] vs. 5.0 [± 3.1]; p = 0.02). Demodex was observed in a large majority (90%) of lens wearers and in 65% of nonwearers using confocal microscopy (p = 0.06). The detection rate was lower in both groups using conventional light microscopy (p = 0.003) where Demodex could only be confirmed in 70% and 60% of lens wearers and nonwearers, respectively. The number of Demodex tended to increase with age (ρ = 0.28, p = 0.08), but Demodex did not appear to affect ocular comfort or any clinical signs (p > 0.05). Contact lens wearers harbor Demodex as frequently as nonwearers and in higher numbers, which is best detected using in vivo confocal microscopy. The significance of these findings is uncertain because no associations were found with any symptoms and signs of dry eye disease.

  19. Hydrophilic acrylic intraocular lens optic and haptics opacification in a diabetic patient: bilateral case report and clinicopathologic correlation.

    PubMed

    Pandey, Suresh K; Werner, Liliana; Apple, David J; Kaskaloglu, Mahmut

    2002-11-01

    To report clinicopathologic and ultrastructural features of two opacified single-piece hydrophilic acrylic intraocular lenses (IOLs) explanted from a diabetic patient. Interventional case report with clinicopathologic correlation. A 64-year-old white female underwent phacoemulsification and implantation of a single-piece hydrophilic acrylic lens (SC60B-OUV; Medical Developmental Research, Inc., Clear Water, FL) in October 1998 in the left eye and in July 1999 in the right eye. The best-corrected visual acuity after surgery was 20/60 in the left eye and 20/50 in the right eye. The patient had a marked decrease in visual acuity in June 2000 as a result of a milky, white opalescence of both lenses. Intraocular lens explantation and exchange was performed in both eyes and the explanted IOLs were submitted to our center for detailed pathologic, histochemical, and ultrastructural evaluation. They were stained with alizarin red and the von Kossa method for calcium, and also underwent scanning electron microscopy and energy dispersive radiograph spectroscopy to ascertain the nature of the deposits leading to opacification. Documentation of calcium deposits confirmed by histochemical stains and surface analyses. Opacification of the IOL was found to be the cause of decreased visual acuity. The opacification involved both the IOL optic and the haptics in the left eye and was confined to the IOL optic in the right eye. Histochemical and ultrastructural analyses revealed that the opacity was caused by deposition of calcium and phosphate within the lens optic and haptics. There are two features that distinguish this case from those reported earlier. This is the first clinicopathologic report of lens opacification that has involved completely the lens optic and the haptics. Second, these two explanted IOLs document the first bilateral case. This process of intraoptic and haptic opacification represents dystrophic calcification of unknown cause. Diabetic patients appear to be

  20. LENS: web-based lens for enrichment and network studies of human proteins

    PubMed Central

    2015-01-01

    Background Network analysis is a common approach for the study of genetic view of diseases and biological pathways. Typically, when a set of genes are identified to be of interest in relation to a disease, say through a genome wide association study (GWAS) or a different gene expression study, these genes are typically analyzed in the context of their protein-protein interaction (PPI) networks. Further analysis is carried out to compute the enrichment of known pathways and disease-associations in the network. Having tools for such analysis at the fingertips of biologists without the requirement for computer programming or curation of data would accelerate the characterization of genes of interest. Currently available tools do not integrate network and enrichment analysis and their visualizations, and most of them present results in formats not most conducive to human cognition. Results We developed the tool Lens for Enrichment and Network Studies of human proteins (LENS) that performs network and pathway and diseases enrichment analyses on genes of interest to users. The tool creates a visualization of the network, provides easy to read statistics on network connectivity, and displays Venn diagrams with statistical significance values of the network's association with drugs, diseases, pathways, and GWASs. We used the tool to analyze gene sets related to craniofacial development, autism, and schizophrenia. Conclusion LENS is a web-based tool that does not require and download or plugins to use. The tool is free and does not require login for use, and is available at http://severus.dbmi.pitt.edu/LENS. PMID:26680011

  1. 40 CFR 62.15215 - What is required for my continuous opacity monitoring system and how are the data used?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... opacity monitoring system and how are the data used? 62.15215 Section 62.15215 Protection of Environment... required for my continuous opacity monitoring system and how are the data used? (a) Install, calibrate, maintain, and operate a continuous opacity monitoring system. (b) Install, evaluate, and operate each...

  2. Asp 58 modulates lens αA-crystallin oligomer formation and chaperone function.

    PubMed

    Takata, Takumi; Nakamura-Hirota, Tooru; Inoue, Rintaro; Morishima, Ken; Sato, Nobuhiro; Sugiyama, Masaaki; Fujii, Noriko

    2018-06-01

    Senile cataract onset is caused by insolubilization of lens proteins. The lens crystallin protein family correctly orders the formation of homo- or hetero-oligomers in lens fiber cells. Because lens fiber cells do not divide, covalent post-translational modifications, such as isomerization of aspartate residues, accumulate with aging. Although many isomerization sites of αA-crystallin have been reported, their structural and functional contributions have never been identified. In this study, αA-crystallin was extracted from aged human lens and separated into each oligomeric state by size exclusion chromatography and electrophoresis. The novel combination methodology of in-solution/gel tryptic digestion with liquid chromatography equipped with mass spectrometry (LC-MS/MS) was used to evaluate the isomerization of Asp 58. The contributions of isomerization to assembly, solubility, and chaperone functions of αA-crystallin were estimated using a series of mutations of Asp 58 in αA-crystallin. The results indicated that the isomerization of Asp 58 depended on the oligomer size and age of the lens. The substitution of Asp 58 for hydrophobic residues increased αA-crystallin oligomer size and decreased solubility. All substitutions decreased the chaperone function of αA-crystallin for aggregates of bovine βL-crystallin and alcohol dehydrogenase. The data indicated that Asp 58 in αA-crystallin was critical for intermolecular interactions in the lens. Our results also suggested that LC-MS/MS-based isomerization analyses of in-gel-digested products could be useful for investigating the isomerization of Asp residues in oligomeric states. This method could also be used to analyze d/l ratios of amino acid residues in soluble protein aggregates. © 2018 Federation of European Biochemical Societies.

  3. Mars dust and cloud opacities and scattering properties

    NASA Technical Reports Server (NTRS)

    Clancy, R. T.; Lee, S. W.

    1992-01-01

    We have recently completed an analysis of the visible emission-phase function (EPF) sequences obtained with the solar-band channel of the Infrared Thermal Mapping (IRTM) instrument onboard the two Viking Orbiters. Roughly 100 of these EPF sequences were gathered during the 1977-1980 period, in which the total broadband (.3-3.0 microns) reflectances of the atmosphere/surface above specific locations on Mars were measured versus emission angle as the spacecraft passed overhead. A multiple scattering radiative transfer program was employed to model the EPF observations in terms of the optical depths of dust/clouds, their single scattering albedos and phase functions, and the Lambert albedos and phase coefficient of the underlying surfaces. Due to the predominance of atmospheric scattering at large atmospheric pathlengths and/or large dust opacities, we were able to obtain strong constraints on the scattering properties of dust/clouds and their opacities for a wide range of latitudes, longitudes, and seasons on Mars.

  4. Light element opacities of astrophysical interest from ATOMIC

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Colgan, J.; Kilcrease, D. P.; Magee, N. H. Jr.

    We present new calculations of local-thermodynamic-equilibrium (LTE) light element opacities from the Los Alamos ATOMIC code for systems of astrophysical interest. ATOMIC is a multi-purpose code that can generate LTE or non-LTE quantities of interest at various levels of approximation. Our calculations, which include fine-structure detail, represent a systematic improvement over previous Los Alamos opacity calculations using the LEDCOP legacy code. The ATOMIC code uses ab-initio atomic structure data computed from the CATS code, which is based on Cowan's atomic structure codes, and photoionization cross section data computed from the Los Alamos ionization code GIPPER. ATOMIC also incorporates a newmore » equation-of-state (EOS) model based on the chemical picture. ATOMIC incorporates some physics packages from LEDCOP and also includes additional physical processes, such as improved free-free cross sections and additional scattering mechanisms. Our new calculations are made for elements of astrophysical interest and for a wide range of temperatures and densities.« less

  5. OCT-based crystalline lens topography in accommodating eyes.

    PubMed

    Pérez-Merino, Pablo; Velasco-Ocana, Miriam; Martinez-Enriquez, Eduardo; Marcos, Susana

    2015-12-01

    Custom Spectral Domain Optical Coherence Tomography (SD-OCT) provided with automatic quantification and distortion correction algorithms was used to measure anterior and posterior crystalline lens surface elevation in accommodating eyes and to evaluate relationships between anterior segment surfaces. Nine young eyes were measured at different accommodative demands. Anterior and posterior lens radii of curvature decreased at a rate of 0.78 ± 0.18 and 0.13 ± 0.07 mm/D, anterior chamber depth decreased at 0.04 ± 0.01 mm/D and lens thickness increased at 0.04 ± 0.01 mm/D with accommodation. Three-dimensional surface elevations were estimated by subtracting best fitting spheres. In the relaxed state, the spherical term accounted for most of the surface irregularity in the anterior lens (47%) and astigmatism (70%) in the posterior lens. However, in accommodated lenses astigmatism was the predominant surface irregularity (90%) in the anterior lens. The RMS of high-order irregularities of the posterior lens surface was statistically significantly higher than that of the anterior lens surface (x2.02, p<0.0001). There was significant negative correlation in vertical coma (Z3 (-1)) and oblique trefoil (Z3 (-3)) between lens surfaces. The astigmatic angle showed high degree of alignment between corneal surfaces, moderate between corneal and anterior lens surface (~27 deg), but differed by ~80 deg between the anterior and posterior lens surfaces (including relative anterior/posterior lens astigmatic angle shifts (10-20 deg).

  6. OCT-based crystalline lens topography in accommodating eyes

    PubMed Central

    Pérez-Merino, Pablo; Velasco-Ocana, Miriam; Martinez-Enriquez, Eduardo; Marcos, Susana

    2015-01-01

    Custom Spectral Domain Optical Coherence Tomography (SD-OCT) provided with automatic quantification and distortion correction algorithms was used to measure anterior and posterior crystalline lens surface elevation in accommodating eyes and to evaluate relationships between anterior segment surfaces. Nine young eyes were measured at different accommodative demands. Anterior and posterior lens radii of curvature decreased at a rate of 0.78 ± 0.18 and 0.13 ± 0.07 mm/D, anterior chamber depth decreased at 0.04 ± 0.01 mm/D and lens thickness increased at 0.04 ± 0.01 mm/D with accommodation. Three-dimensional surface elevations were estimated by subtracting best fitting spheres. In the relaxed state, the spherical term accounted for most of the surface irregularity in the anterior lens (47%) and astigmatism (70%) in the posterior lens. However, in accommodated lenses astigmatism was the predominant surface irregularity (90%) in the anterior lens. The RMS of high-order irregularities of the posterior lens surface was statistically significantly higher than that of the anterior lens surface (x2.02, p<0.0001). There was significant negative correlation in vertical coma (Z3−1) and oblique trefoil (Z3−3) between lens surfaces. The astigmatic angle showed high degree of alignment between corneal surfaces, moderate between corneal and anterior lens surface (~27 deg), but differed by ~80 deg between the anterior and posterior lens surfaces (including relative anterior/posterior lens astigmatic angle shifts (10-20 deg). PMID:26713216

  7. Density of the crystalline lens in obese and nonobese children.

    PubMed

    Acer, Semra; Ağladıoğlu, Sebahat Yılmaz; Pekel, Gökhan; Özhan, Bayram; Çetin, Ebru Nevin; Yağcı, Ramazan; Yıldırım, Cem

    2016-02-01

    To compare crystalline lens density in obese and nonobese children. A total of 40 obese (25 females) and 46 age-sex matched controls (26 females) were included in this prospective study. Children with ocular diseases (except for mild refractive errors), ocular trauma, or surgery and any systemic disorders, including diabetes, were excluded. Lens densitometry (LD), central corneal thickness (CCT), anterior chamber depth (ACD) and corneal volume (CV) were measured by Pentacam HR. Mean participant age was 12.0 ± 1.9 (range, 7.2-18 years) in the obese group and 11.7 ± 2.0 (range, 7.5-16.1 years) in the control group. The BMI was 29.9 ± 4.5 in the obese group and 18.7 ± 2.5 in the control group (P ≤ 0.05). The vertical, horizontal, and areal lens density measurements were higher in obese group than in controls (P ≤ 0.05). There was a positive correlation between BMI and vertical, horizontal, and areal lens density measurements. The difference in CCT, ACD, and CV was not statistically significant between groups (P ≥ 0.05). There is increased lens density in the obese children compared with controls. Pentacam HR may provide objective data about lens density in children. Copyright © 2016 American Association for Pediatric Ophthalmology and Strabismus. Published by Elsevier Inc. All rights reserved.

  8. Molecular chaperone properties of the high molecular weight aggregate from aged lens

    NASA Technical Reports Server (NTRS)

    Takemoto, L.; Boyle, D.; Spooner, B. S. (Principal Investigator)

    1994-01-01

    The high molecular weight aggregate (HMWA) fraction was isolated from the water soluble proteins of aged bovine lenses. Its composition and ability to inhibit heat-induced denaturation and aggregation were compared with the lower molecular weight, oligomeric fraction of alpha isolated from the same lens. Although the major components of both fractions were the alpha-A and alpha-B chains, the HMWA fraction possessed a decreased ability to protect other proteins against heat-induced denaturation and aggregation. Immunoelectron microscopy of both fractions demonstrated that alpha particles from the HMWA fraction contained increased amounts of beta and gamma crystallins, bound to a central region of the supramolecular complex. Together, these results demonstrate that alpha crystallins found in the HMWA fraction possess a decreased ability to protect against heat-induced denaturation and aggregation, and suggest that at least part of this decrease could be due to the increased presence of beta and gamma crystallins complexed to the putative chaperone receptor site of the alpha particles.

  9. Uranium Workers Demonstrate Lower Lobe Predominant Irregular Pneumoconiotic Opacities on Chest Radiographs.

    PubMed

    Kocher, Elizabeth; Rendon, Kristi J; Kesler, Denece; Boyce, Tawny Wilson; Myers, Orrin; Evans, Kandace; Cook, Linda S; Sood, Akshay

    2016-01-01

    There is a paucity of literature on the chest radiographic findings in uranium workers. To characterize the chest radiographic findings of pneumoconiosis in a New Mexican cohort of uranium workers. The most recent results from chest radiographs were abstracted in this cross-sectional study. Radiographs showed small pneumoconiotic opacities of profusion score of ≥ 1/0 in 155/429 (36.1%) uranium workers. The most common shape/size of the primary and secondary opacities was s (90.3%) and t (83.7%) types, respectively. Lower lung zones were the most affected. American Indians were the population group at greatest odds for having profusion score ≥ 1/0 (O.R. 2.65, 95% C.I. 1.61, 4.36). Uranium workers' pneumoconiosis is associated with predominantly lower lobe, irregular, and small opacities. Clinical providers and policymakers must consider uranium workers' pneumoconiosis in the differential diagnosis for lower lobe-predominant interstitial lung disease, in the appropriate exposure setting.

  10. Determinants of lens vault and association with narrow angles in patients from Singapore.

    PubMed

    Tan, Gavin S; He, Mingguang; Zhao, Wanting; Sakata, Lisandro M; Li, Jialiang; Nongpiur, Monisha E; Lavanya, Raghavan; Friedman, David S; Aung, Tin

    2012-07-01

    To describe the distribution and determinants of lens vault and to investigate the association of lens vault with narrow angles. Prospective cross-sectional study. Phakic subjects 50 years and older were evaluated at a primary healthcare clinic with gonioscopy, partial laser interferometry, and anterior segment optical coherence tomography (AS-OCT). Narrow angles were defined as posterior trabecular meshwork not visible for ≥2 quadrants on non-indentation gonioscopy. Lens vault was defined as the perpendicular distance between the anterior pole of the crystalline lens and the horizontal line joining the 2 scleral spurs on horizontal AS-OCT scans. Analysis of covariance, multivariate logistic regression, and area under the receiver operating characteristic curves (AUC) were performed. Of the 2047 subjects recruited, 582 were excluded because of poor image quality or inability to locate scleral spurs, leaving 1465 subjects for analysis. Eyes with narrow angles had greater lens vault compared to eyes with open angles (775.6 µm vs 386.5 µm, P < .0001). Women had significantly greater lens vault than men (497.28 µm vs 438.56 µm, P < .001), and lens vault increased significantly with age (P for trend <.001). Adjusted for age and sex, significant associations with greater lens vault were shorter axial length, shallower anterior chamber depth(ACD), higher intraocular pressure, and more hyperopic spherical equivalent (all P < .001). On multivariate analysis, subjects with lens vault >667.6 µm were more likely to have narrow angles (OR 2.201, 95% CI: 1.070-4.526) compared to those with lens vault ≤462.7 µm. The AUC for lens vault (0.816) and ACD (0.822) for detecting narrow angles were similar (P = .582). Lens vault was independently associated with narrow angles and may be useful in screening to detect eyes with narrow angles. Copyright © 2012 Elsevier Inc. All rights reserved.

  11. Intracapsular lensectomy and sulcus intraocular lens fixation in dogs with primary lens luxation or subluxation.

    PubMed

    Stuhr, Charles M; Schilke, Hillary K; Forte, Christina

    2009-01-01

    To evaluate the postoperative results of lensectomy and sulcus intraocular lens fixation (SIOLF) via an ab interno approach in dogs with progressive lens subluxation or early luxation. Retrospective study. Twenty eyes from 19 dogs presented to the Animal Eye Clinic for lens luxation or subluxation between 1999 and 2006. Medical records were reviewed to evaluate preoperative lens position, vision status, intraocular pressure (IOP), and whether surgery was performed on an emergent or elective nature. Lensectomy and SIOLF were performed and postoperative status including vision, glaucoma, and retinal detachment was assessed. Average age was 8.6 years (range 4-14 years) and 55% (11/20) were terriers. Patients were followed a mean of 29.2 months (range 1-92 months) after surgery. Retinal detachment or secondary glaucoma was observed in 1 of 20 (5%) and 5 of 20 (20%) eyes, respectively, with 1 of 20 (5%) exhibiting both. Mean preoperative IOP was 16 mmHg and preoperative lens position was equally divided between luxated and subluxated lenses. Surgery was performed more frequently as an elective procedure (18/20; 90%) due to normalized IOP vs. an emergency procedure (2/20; 10%). Vision was retained in 70% (14/20) of eyes with a mean time to vision loss of 41 months in the remaining eyes due to glaucoma, retinal detachment, or retinal degeneration. Complications of glaucoma and retinal detachment after SIOLF in this study were less when compared with previously reported incidence rates in the literature for lensectomy alone which may reflect improved patient selection.

  12. In vitro evaluation of UV opacity potential of Aloe vera L. gel from different germplasms.

    PubMed

    Kumar, M Shyam; Datta, P K; Dutta Gupta, S

    2009-04-01

    In this study, lyophilized crude and methanolic extracts of aloe gel from different germplasms (S24, RM, TN, OR, and RJN) of Aloe vera L. were tested for their ultraviolet (UV) opacity potential. UV absorption profiles, sun protection factor (SPF), and percentage blocking of UVA and UVB were considered to test UV opacity potential. Both the extracts showed UV absorption and followed the same path in the wavelength range of 250-400 nm in all the germplasms. Methanolic extract showed a stronger absorptivity than the crude lyophilized extract. Among the tested germplasms, maximum UV opacity property with a SPF of 9.97% and 79.12% UVB blocking was obtained with RJN, whereas a poor response was evident in TN with a SPF of 1.37% and 28.5% UVB blocking at 4 mg/ml methanolic extract. To our knowledge the present work for the first time documents UV opacity properties of A. vera L. gel and opens up new vistas in Aloe gel characterization.

  13. Opacity meter for monitoring exhaust emissions from non-stationary sources

    DOEpatents

    Dec, John Edward

    2000-01-01

    Method and apparatus for determining the opacity of exhaust plumes from moving emissions sources. In operation, a light source is activated at a time prior to the arrival of a diesel locomotive at a measurement point, by means of a track trigger switch or the Automatic Equipment Identification system, such that the opacity measurement is synchronized with the passage of an exhaust plume past the measurement point. A beam of light from the light source passes through the exhaust plume of the locomotive and is detected by a suitable detector, preferably a high-rate photodiode. The light beam is well-collimated and is preferably monochromatic, permitting the use of a narrowband pass filter to discriminate against background light. In order to span a double railroad track and provide a beam which is substantially stronger than background, the light source, preferably a diode laser, must provide a locally intense beam. A high intensity light source is also desirable in order to increase accuracy at the high sampling rates required. Also included is a computer control system useful for data acquisition, manipulation, storage and transmission of opacity data and the identification of the associated diesel engine to a central data collection center.

  14. Ethnic differences in lens parameters measured by ocular biometry in a cataract surgery population.

    PubMed

    Wang, Dajiang; Amoozgar, Behzad; Porco, Travis; Wang, Zhen; Lin, Shan C

    2017-01-01

    To investigate whether differences exist in lens position and other lens parameters among major ethnic groups with cataractous eyes, which may help explain racial differences in angle closure risk. This retrospective, cross-sectional study included 807 adult patients who had cataract surgery between years 2014 and 2016 at the University of California, San Francisco (UCSF). Adult patients of white, Asian, Hispanic and African-American ethnicity were included. Lens position (LP), defined as anterior chamber depth (ACD) + 1/2 lens thickness (LT), was assessed using measurements from optical biometry. Other assessed biometric parameters included axial length (AL), relative lens position (RLP) (defined as LP/AL), and anterior chamber depth (ACD). A total of 807 patients and 1361 eyes were included in this study from a database of patients having cataract surgery. Mean age was 69.2 years (age range from 18 to 101 years old), and 60.3% of patients were women. The mean LP measurements were 5.54±0.32 mm for white, 5.38±0.32 mm for Asian, 5.32±0.30 mm for Hispanic, and 5.40±0.28 mm for African-American participants. After adjusting for age, sex, and AL, significant differences were found when comparing LP in paired comparisons among White cohort with Asians (P<0.001), Hispanics (P<0.001) and African-Americans (P = 0.003). Additionally, when comparing RLP, similar significant results were found when comparing Whites with Asians (P<0.001), Hispanics (P<0.001) and African-Americans (P = 0.002). Lastly, pair-wise comparison of LT between ethnic groups showed significant differences while comparing Asians with Whites (P = 0.001) and Asians with African-Americans (P<0.001). The results of this study suggest that the LP of Hispanic, Asian, and African-American patients are significantly smaller than that of White patients, and among all ethnic groups, Hispanics and after Asians have the smallest LP (P<0.001) and RLP (P<0.001). These findings may have implications for the

  15. Early lens extraction with intraocular lens implantation for the treatment of primary angle closure glaucoma: an economic evaluation based on data from the EAGLE trial

    PubMed Central

    Javanbakht, Mehdi; Azuara-Blanco, Augusto; Burr, Jennifer M; Ramsay, Craig; Cooper, David; Cochran, Claire; Norrie, John; Scotland, Graham

    2017-01-01

    Objective To investigate the cost-effectiveness of early lens extraction with intraocular lens implantation for the treatment of primary angle closure glaucoma (PACG) compared to standard care. Design Cost-effectiveness analysis alongside a multicentre pragmatic two-arm randomised controlled trial. Patients were followed-up for 36 months, and data on health service usage and health state utility were collected and analysed within the trial time horizon. A Markov model was developed to extrapolate the results over a 5-year and 10-year time horizon. Setting 22 hospital eye services in the UK. Population Males and females aged 50 years or over with newly diagnosed PACG or primary angle closure (PAC). Interventions Lens extraction compared to standard care (ie, laser iridotomy followed by medical therapy and glaucoma surgery). Outcome measures Costs of primary and secondary healthcare usage (UK NHS perspective), quality-adjusted life years (QALYs) and the incremental cost-effectiveness ratio (ICER) for lens extraction versus standard care. Results The mean age of participants was 67.5 (8.42), 57.5% were women, 44.6% had both eyes eligible, 1.4% were of Asian ethnicity and 35.4% had PAC. The mean health service costs were higher in patients randomised to lens extraction: £2467 vs £1486. The mean adjusted QALYs were also higher with early lens extraction: 2.602 vs 2.533. The ICER for lens extraction versus standard care was £14 284 per QALY gained at three years. Modelling suggests that the ICER may drop to £7090 per QALY gained by 5 years and that lens extraction may be cost saving by 10 years. Our results are generally robust to changes in the key input parameters and assumptions. Conclusions We find that lens extraction has a 67–89% chance of being cost-effective at 3 years and that it may be cost saving by 10 years. Trial registration number ISRCTN44464607; Results. PMID:28087548

  16. 40 CFR 60.1270 - What is required for my continuous opacity monitoring system and how are the data used?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... opacity monitoring system and how are the data used? 60.1270 Section 60.1270 Protection of Environment... Continuous Emission Monitoring § 60.1270 What is required for my continuous opacity monitoring system and how... system. (b) Install, evaluate, and operate each continuous opacity monitoring system according to § 60.13...

  17. A Comparison of Keyword Subject Searching on Six British University OPACs Online Public Access Catalogs.

    ERIC Educational Resources Information Center

    Aanonson, John

    1987-01-01

    Compares features of online public access catalogs (OPACs) at six British universities: (1) Cambridge; (2) Hull; (3) Newcastle; (4) Surrey; (5) Sussex; and (6) York. Results of keyword subject searches on two topics performed on each of the OPACs are reported and compared. Six references are listed. (MES)

  18. The Searching Behavior of Remote Users: A Study of One Online Public Access Catalog (OPAC).

    ERIC Educational Resources Information Center

    Kalin, Sally W.

    1991-01-01

    Describes a study that was conducted to determine whether the searching behavior of remote users of LIAS (Library Information Access System), Pennsylvania State University's online public access catalog (OPAC), differed from those using the OPAC within the library. Differences in search strategies and in user satisfaction are discussed. (eight…

  19. Gravitational-Like Lens Based on Graphene Ripple.

    PubMed

    Liu, Daqing; Chen, Shuyue; Ma, Ning; Zhao, Xiang; Xu, Zhuo

    2015-10-01

    We conducted a semiclassical study on carrier movement in curved graphene. A previous attempt was made to show that curved graphene is a readily available and cheap laboratory material used to study general relativity effects, especially if the electron energies satisfy 4μeV ≪ |E| ≪ 3eV. Furthermore, a gravitational-like lens can be constructed based on a special graphene ripple; this lens has neither chromatic nor cometic aberration. One can design an ideal electron lens using a graphene ripple.

  20. Disinfection capacity of PuriLens contact lens cleaning unit against Acanthamoeba.

    PubMed

    Hwang, Thomas S; Hyon, Joon Young; Song, Jae Kyung; Reviglio, Victor E; Spahr, Harry T; O'Brien, Terrence P

    2004-01-01

    The PuriLens contact lens system is indicated for cleaning and disinfection of soft (hydrophilic) contact lenses by means of subsonic agitation to remove lens deposits and microorganisms, and ultraviolet irradiation of the storage solution for disinfection. The capacity of the PuriLens system to disinfect storage solutions contaminated with known concentrations of Staphylococcus aureus, Pseudomonas aeruginosa, and Acanthamoeba species was evaluated. An in vitro assessment of the antibacterial and antiparasitic efficacy of the PuriLens system was performed. Separated batches of the storage solution for the cleansing system were contaminated with stock strains of S. aureus and P. aeruginosa. A comparison of the microbiologic content was made between the solution before and after the cycle. The PuriLens system effectively eradicated S. aureus and P. aeruginosa organisms after a 15-minute cycle. However, viable cysts of acanthamoeba were recovered in the solution after the 15-minute cycle. The PuriLens system is highly efficient in protecting against contamination with common bacterial ocular pathogens. Acanthamoeba cysts, however, can survive in the solution or contact lens bath undergoing integrated subsonic debridement and indirect ultraviolet light disinfection. Use of chemical disinfecting solutions that contain agents such as chlorhexidine or other cationic antiseptics may be advisable in conjunction with use of the PuriLens device, especially in high-risk settings.

  1. Bibliographic Displays in OPACs and Web Catalogs: How Well Do They Comply with Display Guidelines?

    ERIC Educational Resources Information Center

    Cherry, Joan M.

    1998-01-01

    Evaluation of data from assessments of full bibliographic displays in academic library OPACs (online public access catalogs) and World Wide Web catalogs against a checklist of desirable features found that OPAC displays scored 58% and Web displays scored 60%. Discusses weaknesses, focusing on those found in the majority of the displays…

  2. The status of intercellular junctions in established lens epithelial cell lines

    PubMed Central

    Dave, Alpana; Craig, Jamie E.

    2012-01-01

    Purpose Cataract is the major cause of vision-related disability worldwide. Mutations in the crystallin genes are the most common known cause of inherited congenital cataract. Mutations in the genes associated with intercellular contacts, such as Nance-Horan Syndrome (NHS) and Ephrin type A receptor-2 (EPHA2), are other recognized causes of congenital cataract. The EPHA2 gene has been also associated with age-related cataract, suggesting that intercellular junctions are important in not only lens development, but also in maintaining lens transparency. The purpose of this study was to analyze the expression and localization of the key cell junction and cytoskeletal proteins, and of NHS and EPHA2, in established lens epithelial cell lines to determine their suitability as model epithelial systems for the functional investigation of genes involved in intercellular contacts and implicated in cataract. Methods The expression and subcellular localization of occludin and zona occludens protein-1 (ZO-1), which are associated with tight junctions; E-cadherin, which is associated with adherence junctions; and the cytoskeletal actin were analyzed in monolayers of a human lens epithelial cell line (SRA 01/04) and a mouse lens epithelial cell line (αTN4). In addition, the expression and subcellular localization of the NHS and EPHA2 proteins were analyzed in these cell lines. Protein or mRNA expression was respectively determined by western blotting or reverse transcription-polymerase chain reaction (RT–PCR), and localization was determined by immunofluorescence labeling. Results Human SRA 01/04 and mouse αTN4 lens epithelial cells expressed either the proteins of interest or their encoding mRNA. Occludin, ZO-1, and NHS proteins localized to the cellular periphery, whereas E-cadherin, actin, and EPHA2 localized in the cytoplasm in these cell lines. Conclusions The human SRA 01/04 and mouse αTN4 lens epithelial cells express the key junctional proteins. The localization

  3. Protein size resolution in human eye lenses by dynamic light scattering after in vivo measurements: first analysis of a clinical validation

    NASA Astrophysics Data System (ADS)

    Dierks, Karsten; Dieckmann, Matthias; Niederstrasser, Dirk; Schwartz, R.; Wegener, Alfred R.

    1995-01-01

    Laser light source powers of our instrument LEPOSIAR are minimized so that dynamic light scattering (DLS) measurements can be conducted with lowest intensity levels on human eye lenses (3.2 mW/cm2) within measurement times of 3 to 5 seconds. We describe an extension of DLS and an eye lens characterization along the optical axis (OA), revealing the molecular size ranges together with distributions found in lens regions parallel to the OA. The microstructures of various lens regions are separated by the analyzed radius distributions reflecting the visco-elastic properties of the eye lens. Detailed analysis and applied statistical categorization of results are described. The data obtained by DLS allow for an objective interpretation of opacity occurrences on molecular size range which are related to refraction anomalies. Apart from changes in color and fluorescence properties, the refractive anomalies can be assumed as the origin of the cataract. The bimodal radius distributions are characterized as a function of patient ages varying from 9 to 85 years. Our clinical study on 42 subjects proves a size decrease of the monomeric fraction with age, whereby their relative frequency of occurrence decreases. The larger polymeric radius fractions which are detected in lenses of all subjects increase with their age. An increase of protein polymer size is likely to be linked to the decrease of the (gamma) -crystallin fraction in old eye lens nuclei. Our preliminary analysis of clinical results is corresponding to the chemical gradients parallel to the OA of the lenses which are reported by O. Hockwin after examination on extracted eye lenses. The normalization of the lens densitometric data derived after Scheimpflug- photography against the protein size fraction analysis by DLS is performed. As a comparison mean between both techniques on identical eye lenses, an absorption corrected densitometry is conducted for the first time.

  4. Research on Spectroscopy, Opacity, and Atmospheres

    NASA Technical Reports Server (NTRS)

    Oliversen, Ronald (Technical Monitor); Kurucz, Robert L.

    2004-01-01

    I propose to continue providing observers with basic data for interpreting spectra from stars, novas, supernovas, clusters, and galaxies. These data will include allowed forbidden line lists both laboratory and computed, for the first five to ten ions of all atoms and for all relevant diatomic molecules. I will eventually expend to all ions of the first thirty elements to treat far UV end X-ray spectra, and for envelope opacities. I also include triatomic molecules providing by other researchers. I have made CDs with Partridge and Schwanke's water data for work on M stars.The luna data also serve as input to my model atmosphere and synthesis programs that generated energy distributions, photometry, limb darkening, and spectra that can be used for planning observations and for fitting observed spectra. The spectrum synthesis programs produce detailed plots with the line identified. Grids of stellar spectra can be used for radial velocity-, rotation-, or abundance templates and for population synthesis. I am fitting spectra of bright stars to test the data and to produce atlases to guide observer. For each star the whole spectrum is computed from the UV to the far IR. The line data, opacities, models, spectra, and programs are freely distributed on CDs and on my web site and represent a unique resource for many NASA programs.

  5. Opacity annotation of diffuse lung diseases using deep convolutional neural network with multi-channel information

    NASA Astrophysics Data System (ADS)

    Mabu, Shingo; Kido, Shoji; Hashimoto, Noriaki; Hirano, Yasushi; Kuremoto, Takashi

    2018-02-01

    This research proposes a multi-channel deep convolutional neural network (DCNN) for computer-aided diagnosis (CAD) that classifies normal and abnormal opacities of diffuse lung diseases in Computed Tomography (CT) images. Because CT images are gray scale, DCNN usually uses one channel for inputting image data. On the other hand, this research uses multi-channel DCNN where each channel corresponds to the original raw image or the images transformed by some preprocessing techniques. In fact, the information obtained only from raw images is limited and some conventional research suggested that preprocessing of images contributes to improving the classification accuracy. Thus, the combination of the original and preprocessed images is expected to show higher accuracy. The proposed method realizes region of interest (ROI)-based opacity annotation. We used lung CT images taken in Yamaguchi University Hospital, Japan, and they are divided into 32 × 32 ROI images. The ROIs contain six kinds of opacities: consolidation, ground-glass opacity (GGO), emphysema, honeycombing, nodular, and normal. The aim of the proposed method is to classify each ROI into one of the six opacities (classes). The DCNN structure is based on VGG network that secured the first and second places in ImageNet ILSVRC-2014. From the experimental results, the classification accuracy of the proposed method was better than the conventional method with single channel, and there was a significant difference between them.

  6. Conceptual design of initial opacity experiments on the national ignition facility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Heeter, R.  F.; Bailey, J.  E.; Craxton, R.  S.

    Accurate models of X-ray absorption and re-emission in partly stripped ions are necessary to calculate the structure of stars, the performance of hohlraums for inertial confinement fusion and many other systems in high-energy-density plasma physics. Despite theoretical progress, a persistent discrepancy exists with recent experiments at the Sandia Z facility studying iron in conditions characteristic of the solar radiative–convective transition region. The increased iron opacity measured at Z could help resolve a longstanding issue with the standard solar model, but requires a radical departure for opacity theory. To replicate the Z measurements, an opacity experiment has been designed for the National Facility (NIF). The design uses established techniques scaled to NIF. A laser-heated hohlraum will produce X-ray-heated uniform iron plasmas in local thermodynamic equilibrium (LTE) at temperaturesmore » $${\\geqslant}150$$ eV and electron densities$${\\geqslant}7\\times 10^{21}~\\text{cm}^{-3}$$. The iron will be probed using continuum X-rays emitted in a$${\\sim}200$$ ps,$${\\sim}200~\\unicode[STIX]{x03BC}\\text{m}$$diameter source from a 2 mm diameter polystyrene (CH) capsule implosion. In this design,$2/3$$of the NIF beams deliver 500 kJ to the$${\\sim}6$$ mm diameter hohlraum, and the remaining$$1/3$directly drive the CH capsule with 200 kJ. Calculations indicate this capsule backlighter should outshine the iron sample, delivering a point-projection transmission opacity measurement to a time-integrated X-ray spectrometer viewing down the hohlraum axis. Preliminary experiments to develop the backlighter and hohlraum are underway, informing simulated measurements to guide the final design.« less

  7. Implicit Monte Carlo with a linear discontinuous finite element material solution and piecewise non-constant opacity

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wollaeger, Ryan T.; Wollaber, Allan B.; Urbatsch, Todd J.

    2016-02-23

    Here, the non-linear thermal radiative-transfer equations can be solved in various ways. One popular way is the Fleck and Cummings Implicit Monte Carlo (IMC) method. The IMC method was originally formulated with piecewise-constant material properties. For domains with a coarse spatial grid and large temperature gradients, an error known as numerical teleportation may cause artificially non-causal energy propagation and consequently an inaccurate material temperature. Source tilting is a technique to reduce teleportation error by constructing sub-spatial-cell (or sub-cell) emission profiles from which IMC particles are sampled. Several source tilting schemes exist, but some allow teleportation error to persist. We examinemore » the effect of source tilting in problems with a temperature-dependent opacity. Within each cell, the opacity is evaluated continuously from a temperature profile implied by the source tilt. For IMC, this is a new approach to modeling the opacity. We find that applying both source tilting along with a source tilt-dependent opacity can introduce another dominant error that overly inhibits thermal wavefronts. We show that we can mitigate both teleportation and under-propagation errors if we discretize the temperature equation with a linear discontinuous (LD) trial space. Our method is for opacities ~ 1/T 3, but we formulate and test a slight extension for opacities ~ 1/T 3.5, where T is temperature. We find our method avoids errors that can be incurred by IMC with continuous source tilt constructions and piecewise-constant material temperature updates.« less

  8. Clinical and biometric determinants of actual lens position after cataract surgery.

    PubMed

    Plat, Julien; Hoa, Didier; Mura, Frederic; Busetto, Timothe; Schneider, Christelle; Payerols, Arnaud; Villain, Max; Daien, Vincent

    2017-02-01

    To evaluate the preoperative clinical and biometric determinants associated with the actual lens position after cataract surgery. Department of Ophthalmology, University Hospital of Montpellier, France. Prospective longitudinal cohort study. The data collected included clinical factors (age, sex, history of vitrectomy) and biometry factors (axial length [AL], anterior chamber depth [ACD], lens thickness, white-to-white [WTW] distance) that might affect actual lens position. Each patient had optical low-coherence reflectometry biometry (Lenstar) preoperatively and 1 month postoperatively. The actual lens position was measured as the postoperative position of the center of the intraocular lens (IOL). Patients were stratified into 3 groups by type of IOL: Acrysof SN60WF or SN6AT (Group 1), Tecnis ZCB00 or ZCT (Group 2), and Asphina 409 MV (Group 3). The study comprised 168 eyes (mean age 73.3 years ± 9.8 [SD]). The mean actual lens position was 4.88 ± 0.29 mm, 5.01 ± 0.29 mm, and 5.05 ± 0.32 mm in Group 1 (n = 67 eyes), Group 2 (n = 52 eyes), and Group 3 (n = 49 eyes), respectively. In the overall population, AL, ACD, anterior segment depth, and WTW distance were correlated with actual lens position (r = 0.48, P < .0001; r = 0.64, P < .001; r = 0.58, P < .0001; r = 0.39, P < .001, respectively). The AL, ACD, anterior segment depth, and WTW distance correlated with actual lens position after cataract surgery. The integration of these data in IOL formulas could help improve refractive outcomes after the surgery. Copyright © 2017 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  9. Library OPACs on the Web: Finding and Describing Directories.

    ERIC Educational Resources Information Center

    Henry, Marcia

    1997-01-01

    Provides current descriptions of some of the major directories that link to library catalogs on the World Wide Web. Highlights include LibWeb; Hytelnet; WebCats; WWW Library Directory; and techniques for finding new library OPAC (online public access catalog) directories. (LRW)

  10. Ferulic Acid Suppresses Amyloid β Production in the Human Lens Epithelial Cell Stimulated with Hydrogen Peroxide

    PubMed Central

    Nagai, Noriaki; Kotani, Sachiyo; Mano, Yu; Ueno, Akina; Ito, Yoshimasa; Kitaba, Toshio; Takata, Takumi

    2017-01-01

    It is well known that oxidative stresses induce the production of amyloid β (Aβ) in the brain, lens, and retina, leading to age-related diseases. In the present study, we investigated the effects of ferulic acid on the Aβ levels in H2O2-stimulated human lens epithelial (HLE) SRA 01/04 cells. Three types of Aβ peptides (Aβ1-40, Aβ1-42, and Aβ1-43) were measured by ELISA, and the levels of mRNA for the expressed proteins related to Aβ production (APP, BACE1, and PS proteins) and degradation (ADAM10, NEP, and ECE1 proteins) were determined by quantitative real-time RT-PCR. H2O2 stimulation augmented gene expression of the proteins related to Aβ production, resulting in the production of three types of Aβ peptides. Treatment with 0.1 μM ferulic acid attenuated the augmentations of gene expression and production of the proteins related to the secretion of three types of Aβ peptides in the H2O2-stimulated HLE cells. These results provided evidence of antioxidative functions of ferulic acid for lens epithelial cells. PMID:28409157

  11. Tunable Polymer Lens

    DTIC Science & Technology

    2008-08-04

    can also be initiated mechanically to produce variable lenses [9-11]. Recent work shows lens properties of a controlled liquid drop shape, with no... liquid crystal spherical lens ," Appl. Phys. Lett. 84, 4789-4791 (2004). 3. H. W. Ren, D. W. Fox, B. Wu, and S. T. Wu, " Liquid crystal lens with large...and S. S. Lee, "Focal tunable liquid lens integrated with an electromagnetic actuator," Appl. Phys. Lett. 90, 121129 (2007). 10. H. W. Ren, D. Fox

  12. Adjustable internal structure for reconstructing gradient index profile of crystalline lens.

    PubMed

    Bahrami, Mehdi; Goncharov, Alexander V; Pierscionek, Barbara K

    2014-03-01

    Employing advanced technologies in studying the crystalline lens of the eye has improved our understanding of the refractive index gradient of the lens. Reconstructing and studying such a complex structure requires models with adaptable internal geometry that can be altered to simulate geometrical and optical changes of the lens with aging. In this Letter, we introduce an optically well-defined, geometrical structure for modeling the gradient refractive index profile of the crystalline lens with the advantage of an adjustable internal structure that is not available with existing models. The refractive index profile assigned to this rotationally symmetric geometry is calculated numerically, yet it is shown that this does not limit the model. The study provides a basis for developing lens models with sophisticated external and internal structures without the need for analytical solutions to calculate refractive index profiles.

  13. How should initial fit inform soft contact lens prescribing.

    PubMed

    Boychev, Nikolay; Laughton, Deborah S; Bharwani, Gulshan; Ghuman, Hafsa; Wolffsohn, James S

    2016-06-01

    To investigate how initial HEMA and silicone-hydrogel (SiHy) contact lens fit on insertion, which informs prescribing decisions, reflect end of day fit. Thirty participants (aged 22.9±4.9 years) were fitted contralaterally with HEMA and SiHy contact lenses. Corneal topography and tear break-up time were assessed pre-lens wear. Centration, lag, post-blink movement during up-gaze and push-up recovery speed were recorded after 5,10,20min and 8h of contact lens wear by a digital slit-lamp biomicroscope camera, along with reported comfort. Lens fit metrics were analysed using bespoke software. Comfort and centration were similar with the HEMA and SiHy lenses (p>0.05), but comfort decreased with time (p<0.01) whereas centration remained stable (F=0.036, p=0.991). Movement-on-blink and lag were greater with the HEMA than the SiHy lens (p<0.01), but movement-on-blink decreased with time after insertion (F=22.423, p<0.001) whereas lag remained stable (F=1.967, p=0.129). Push-up recovery speed was similar with the HEMA and the SiHy lens 5-20min after insertion (p>0.05), but was slower with SiHy after 8h wear (p=0.016). Lens movement on blink and push-up recovery speed was predictive of the movement after 8h of wear after 10-20min SiHy wear, but after 5 to 20min of HEMA lens wear. A HEMA or SiHy contact lens with poor movement on blink/push-up after at least 10min after insertion should be rejected. Copyright © 2015 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  14. Image registration reveals central lens thickness minimally increases during accommodation

    PubMed Central

    Schachar, Ronald A; Mani, Majid; Schachar, Ira H

    2017-01-01

    Purpose To evaluate anterior chamber depth, central crystalline lens thickness and lens curvature during accommodation. Setting California Retina Associates, El Centro, CA, USA. Design Healthy volunteer, prospective, clinical research swept-source optical coherence biometric image registration study of accommodation. Methods Ten subjects (4 females and 6 males) with an average age of 22.5 years (range: 20–26 years) participated in the study. A 45° beam splitter attached to a Zeiss IOLMaster 700 (Carl Zeiss Meditec Inc., Jena, Germany) biometer enabled simultaneous imaging of the cornea, anterior chamber, entire central crystalline lens and fovea in the dilated right eyes of subjects before, and during focus on a target 11 cm from the cornea. Images with superimposable foveal images, obtained before and during accommodation, that met all of the predetermined alignment criteria were selected for comparison. This registration requirement assured that changes in anterior chamber depth and central lens thickness could be accurately and reliably measured. The lens radii of curvatures were measured with a pixel stick circle. Results Images from only 3 of 10 subjects met the predetermined criteria for registration. Mean anterior chamber depth decreased, −67 μm (range: −0.40 to −110 μm), and mean central lens thickness increased, 117 μm (range: 100–130 μm). The lens surfaces steepened, anterior greater than posterior, while the lens, itself, did not move or shift its position as appeared from the lack of movement of the lens nucleus, during 7.8 diopters of accommodation, (range: 6.6–9.7 diopters). Conclusion Image registration, with stable invariant references for image correspondence, reveals that during accommodation a large increase in lens surface curvatures is associated with only a small increase in central lens thickness and no change in lens position. PMID:28979092

  15. Lens Systems for Sky Surveys and Space Surveillance

    NASA Astrophysics Data System (ADS)

    Ackermann, M.; McGraw, J.; Zimmer, P.

    2013-09-01

    Since the early days of astrophotography, lens systems have played a key role in capturing images of the night sky. The first images were attempted with visual-refractors. These were soon followed with color-corrected refractors and finally specially designed photo-refractors. Being telescopes, these instruments were of long-focus and imaged narrow fields of view. Simple photographic lenses were soon put into service to capture wide-field images. These lenses also had the advantage of requiring shorter exposure times than possible using large refractors. Eventually, lenses were specifically designed for astrophotography. With the introduction of the Schmidt-camera and related catadioptric systems, the popularity of astrograph lenses declined, but surprisingly, a few remained in use. Over the last 30 years, as small CCDs have displaced large photographic plates, lens systems have again found favor for their ability to image great swaths of sky in a relatively small and simple package. In this paper, we follow the development of lens-based astrograph systems from their beginnings through the current use of both commercial and custom lens systems for sky surveys and space surveillance. Some of the optical milestones discussed include the early Petzval-type portrait lenses, the Ross astrographic lens and the current generation of optics such as the commercial 200mm camera lens by Canon, and the Russian VT-53e in service with ISON.

  16. Opacplot2: Enabling tabulated EoS and opacity compatibility for HEDLP simulations with the FLASH code

    NASA Astrophysics Data System (ADS)

    Laune, Jordan; Tzeferacos, Petros; Feister, Scott; Fatenejad, Milad; Yurchak, Roman; Flocke, Norbert; Weide, Klaus; Lamb, Donald

    2017-10-01

    Thermodynamic and opacity properties of materials are necessary to accurately simulate laser-driven laboratory experiments. Such data are compiled in tabular format since the thermodynamic range that needs to be covered cannot be described with one single theoretical model. Moreover, tabulated data can be made available prior to runtime, reducing both compute cost and code complexity. This approach is employed by the FLASH code. Equation of state (EoS) and opacity data comes in various formats, matrix-layouts, and file-structures. We discuss recent developments on opacplot2, an open-source Python module that manipulates tabulated EoS and opacity data. We present software that builds upon opacplot2 and enables easy-to-use conversion of different table formats into the IONMIX format, the native tabular input used by FLASH. Our work enables FLASH users to take advantage of a wider range of accurate EoS and opacity tables in simulating HELP experiments at the National Laser User Facilities.

  17. Research on Spectroscopy, Opacity, and Atmospheres

    NASA Technical Reports Server (NTRS)

    Kurucz, Robert L.; West, Donald (Technical Monitor)

    2001-01-01

    With this funding I produced a web site kurucz.harvard.edu that can also be accessed by FTP. it has a 73GB disk that holds all of my atomic and diatomic molecular data, my tables of distribution function opacities, my grids of model atmospheres, colors, fluxes, etc., my programs that are ready for distribution, and most of my recent papers. Atlases and computed spectra will be added as they are completed. New atomic and molecular calculations will be added as they are completed.

  18. Site specific oxidation of amino acid residues in rat lens γ-crystallin induced by low-dose γ-irradiation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kim, Ingu; Saito, Takeshi; Research Reactor Institute, Kyoto University, Kumatori, Osaka 590-0494

    Although cataracts are a well-known age-related disease, the mechanism of their formation is not well understood. It is currently thought that eye lens proteins become abnormally aggregated, initially causing clumping that scatters the light and interferes with focusing on the retina, and ultimately resulting in a cataract. The abnormal aggregation of lens proteins is considered to be triggered by various post-translational modifications, such as oxidation, deamidation, truncation and isomerization, that occur during the aging process. Such modifications, which are also generated by free radical and reactive oxygen species derived from γ-irradiation, decrease crystallin solubility and lens transparency, and ultimately leadmore » to the development of a cataract. In this study, we irradiated young rat lenses with low-dose γ-rays and extracted the water-soluble and insoluble protein fractions. The water-soluble and water-insoluble lens proteins were digested with trypsin, and the resulting peptides were analyzed by LC-MS. Specific oxidation sites of methionine, cysteine and tryptophan in rat water-soluble and -insoluble γE and γF-crystallin were determined by one-shot analysis. The oxidation sites in rat γE and γF-crystallin resemble those previously identified in γC and γD-crystallin from human age-related cataracts. Our study on modifications of crystallins induced by ionizing irradiation may provide useful information relevant to human senile cataract formation. - Highlights: • Low-dose γ-rays induced oxidation at specific residues in γE- and γF-crystallin. • The number of oxidation sites was higher in insoluble than soluble crystallins. • γ-Irradiation closely mimics the oxidation that occur in senile human cataracts.« less

  19. Night and Day: The Opacity of Clouds Measured by the Mars Orbiter Laser Altimeter (MOLA)

    NASA Technical Reports Server (NTRS)

    Neumann, G. A.; Wilson, R. J.

    2006-01-01

    The Mars Orbiter Laser Altimeter (MOLA) [l] on the Mars Global Surveyor spacecraft ranged to clouds over the course of nearly two Mars years [2] using an active laser ranging system. While ranging to the surface, the instrument was also able to measure the product of the surface reflectivity with the two-way atmospheric transmission at 1064 nm. Furthermore, the reflectivity has now been mapped over seasonal cycles using the passive radiometric capability built into MOLA [3]. Combining these measurements, the column opacity may be inferred. MOLA uniquely provides these measurements both night and day. This study examines the pronounced nighttime opacity of the aphelion season tropical water ice clouds, and the indiscernibly low opacity of the southern polar winter clouds. The water ice clouds (Figure 1) do not themselves trigger the altimeter but have measured opacities tau > 1.5 and are temporally and spatially correlated with temperature anomalies predicted by a Mars Global Circulation Model (MGCM) that incorporates cloud radiative effects [4]. The south polar CO2 ice clouds trigger the altimeter with a very high backscatter cross-section over a thickness of 3-9 m and are vertically dispersed over several km, but their total column opacities lie well below the MOLA measurement limit of tau = 0.7. These clouds correspond to regions of supercooled atmosphere that may form either very large specularly reflecting particles [2] or very compact, dense concentrations (>5x10(exp 6)/cu m) of 100-p particles

  20. LC-MS display of the total modified amino acids in cataract lens proteins and in lens proteins glycated by ascorbic acid in vitro.

    PubMed

    Cheng, Rongzhu; Feng, Qi; Ortwerth, Beryl J

    2006-05-01

    We previously reported chromatographic evidence supporting the similarity of yellow chromophores isolated from aged human lens proteins, early brunescent cataract lens proteins and calf lens proteins ascorbylated in vitro [Cheng, R. et al. Biochimica et Biophysica Acta 1537, 14-26, 2001]. In this paper, new evidence supporting the chemical identity of the modified amino acids in these protein populations were collected by using a newly developed two-dimensional LC-MS mapping technique supported by tandem mass analysis of the major species. The pooled water-insoluble proteins from aged normal human lenses, early stage brunescent cataract lenses and calf lens proteins reacted with or without 20 mM ascorbic acid in air for 4 weeks were digested with a battery of proteolytic enzymes under argon to release the modified amino acids. Aliquots equivalent to 2.0 g of digested protein were subjected to size-exclusion chromatography on a Bio-Gel P-2 column and four major A330nm-absorbing peaks were collected. Peaks 1, 2 and 3, which contained most of the modified amino acids were concentrated and subjected to RP-HPLC/ESI-MS, and the mass elution maps were determined. The samples were again analyzed and those peaks with a 10(4) - 10(6) response factor were subjected to MS/MS analysis to identify the daughter ions of each modification. Mass spectrometric maps of peaks 1, 2 and 3 from cataract lenses showed 58, 40 and 55 mass values, respectively, ranging from 150 to 600 Da. Similar analyses of the peaks from digests of the ascorbylated calf lens proteins gave 81, 70 and 67 mass values, respectively, of which 100 were identical to the peaks in the cataract lens proteins. A total of 40 of the major species from each digest were analyzed by LC-MS/MS and 36 were shown to be identical. Calf lens proteins incubated without ascorbic acid showed several similar mass values, but the response factors were 100 to 1000-fold less for every modification. Based upon these data, we conclude

  1. Open-Source Tools for Enhancing Full-Text Searching of OPACs: Use of Koha, Greenstone and Fedora

    ERIC Educational Resources Information Center

    Anuradha, K. T.; Sivakaminathan, R.; Kumar, P. Arun

    2011-01-01

    Purpose: There are many library automation packages available as open-source software, comprising two modules: staff-client module and online public access catalogue (OPAC). Although the OPAC of these library automation packages provides advanced features of searching and retrieval of bibliographic records, none of them facilitate full-text…

  2. Conjunctival epithelial flap in continuous contact lens wear.

    PubMed

    Graham, Andrew D; Truong, Tan N; Lin, Meng C

    2009-04-01

    Composed of sheets of cells detached from the underlying conjunctiva, conjunctival epithelial flap (CEF) is a recently reported phenomenon associated with contact lens wear with potential consequences for ocular health. Although CEF is generally asymptomatic, it is not known to what extent it might increase the longer-term risk of discomfort, inflammatory response, or infection. In this study, we use survival analysis methods to obtain unbiased estimates of the probability of developing CEF, the mean survival time free of CEF, and the effects of age, gender, ethnicity, and contact lens type. Two hundred four subjects were recruited for a continuous wear (CW) study of silicone hydrogel (SiH) and gas permeable (GP) contact lenses. Subjects were examined by optometrists throughout contact lens adaptation and CW periods. Statistical methods included the Kaplan-Meier nonparametric estimator of the survival function and the Cox proportional hazards model for estimating the relative effects of covariates. Of the 204 subjects, 72 (35%) developed CEF. In 64% of cases, CEFs were observed bilaterally. The majority of cases (90.3%) presented with CEF in the superior conjunctiva. Mean survival time free of CEF was longer for GP lenses (94.3 days) than for SiH lenses (76.5 days), and the probability of developing CEF was significantly greater for SiH lenses (p = 0.002). Although there was some evidence that women and non-Asians remain free of CEF longer, the effects of age, gender, and ethnicity were not statistically significant. There was a significantly increased risk of CEF in subjects wearing SiH lenses, compared with GP lenses. Subjects wearing SiH lenses remained free of CEF for a shorter time on average. Further study is needed to determine whether the increased incidence of CEF in CW with SiH lenses poses an increased risk of adverse ocular response or infection.

  3. AutoLens: Automated Modeling of a Strong Lens's Light, Mass and Source

    NASA Astrophysics Data System (ADS)

    Nightingale, J. W.; Dye, S.; Massey, Richard J.

    2018-05-01

    This work presents AutoLens, the first entirely automated modeling suite for the analysis of galaxy-scale strong gravitational lenses. AutoLens simultaneously models the lens galaxy's light and mass whilst reconstructing the extended source galaxy on an adaptive pixel-grid. The method's approach to source-plane discretization is amorphous, adapting its clustering and regularization to the intrinsic properties of the lensed source. The lens's light is fitted using a superposition of Sersic functions, allowing AutoLens to cleanly deblend its light from the source. Single component mass models representing the lens's total mass density profile are demonstrated, which in conjunction with light modeling can detect central images using a centrally cored profile. Decomposed mass modeling is also shown, which can fully decouple a lens's light and dark matter and determine whether the two component are geometrically aligned. The complexity of the light and mass models are automatically chosen via Bayesian model comparison. These steps form AutoLens's automated analysis pipeline, such that all results in this work are generated without any user-intervention. This is rigorously tested on a large suite of simulated images, assessing its performance on a broad range of lens profiles, source morphologies and lensing geometries. The method's performance is excellent, with accurate light, mass and source profiles inferred for data sets representative of both existing Hubble imaging and future Euclid wide-field observations.

  4. Effects of Progressive Addition Lens Wear on Digital Work in Pre-presbyopes

    PubMed Central

    Kee, Chea-su; Leung, Tsz Wing; Kan, Ka-hung; Lam, Christie Hang-I

    2018-01-01

    SIGNIFICANCE Growing popularity of handheld digital devices imposes significant challenges to our visual system and clinical management. This study aimed to determine the effects of lens design on parameters that may influence the refractive management of pre-presbyopic adult computer users. PURPOSE To determine the effects of wearing conventional single-vision lenses (SVL) versus progressive addition lenses (PAL) on the working distance and refractive status. METHODS Adult computer users, recruited from two age cohorts (18 to 25 years, n = 19; 30 to 40 years, n = 45), were prescribed SVLs and PALs designed for use with handheld digital devices. For each lens type, the working distance and refractive shift (post-task − pre-task) were measured immediately after lens delivery (T0) and after 1 month of lens wear (T1). Working distances were recorded with an automatic ultrasound device while the participants were playing a video game. Refractive status through the subjects' glasses was measured before (pre-task) and after playing the game (post-task). Questionnaires assessing the frequencies of 10 digital work–related visual symptoms were conducted for both lens types at T1. RESULTS Switching from SVL to PAL increased the working distance in both cohorts (mean ± SEM = 1.88 ± 0.60 cm; P = .002) and induced a small but significant positive refractive shift (+0.08 ± 0.04 D, P = .021) in the older cohort at T1. In the younger cohort, the changes in working distance due to the switching lens design were correlated with myopic error (r = +0.66, P = .002). In the older cohort, the changes in refractive shift due to switching lens design were correlated with amplitude of accommodation at both time points (r for T0 and T1 = −0.32 and −0.30, respectively; both P < .05). Progressive addition lens was rated as causing less “increased sensitivity to light” compared with SVL. CONCLUSIONS Switching from SVL to PAL increased the working distance and induced a positive

  5. Lens material and formulation of multipurpose solutions affects contact lens disinfection.

    PubMed

    Santos, Lívia; Oliveira, Rosário; Oliveira, M Elisabete C D Real; Azeredo, Joana

    2011-08-01

    To assess the disinfection efficacy of multipurpose solutions (MPS) against different bacterial species adhered either to silicon hydrogel or to conventional hydrogel contact lenses (CLs). The influences of the MPS formulation and the chemical composition of the lens material were investigated. This investigation followed the standard 14729, which establishes the guidelines for assessing CL disinfecting solutions. Two commercially available (Opti-Free(®) Express(®) and Renu(®) Multiplus) solutions and one recalled solution (Complete(®) MoisturePlus™) were used in this study. After disinfection, the number of survivors was estimated by the colony forming units' method. The lens material appears to influence disinfection. The conventional hydrogel polymacon exhibited the highest disinfection scores, a fact that should be related with the lack of electrostatic attraction towards the biocides and its hydrophilicity. The MPS formulation appears to have influence in disinfection efficacy as well. For most adhered bacteria, Opti-Free(®) was capable of reducing cell concentration in 4-log. Disinfection results from multivariate factors and this study confirmed that the lens material and the MPS play a very important role in the disinfection efficacy of CL. Copyright © 2011. Published by Elsevier Ltd.

  6. 40 CFR 75.14 - Specific provisions for monitoring opacity.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... PROGRAMS (CONTINUED) CONTINUOUS EMISSION MONITORING Monitoring Provisions § 75.14 Specific provisions for monitoring opacity. (a) Coal-fired units and oil-fired units. The owner or operator shall meet the general... 40 Protection of Environment 16 2010-07-01 2010-07-01 false Specific provisions for monitoring...

  7. 40 CFR 75.14 - Specific provisions for monitoring opacity.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... PROGRAMS (CONTINUED) CONTINUOUS EMISSION MONITORING Monitoring Provisions § 75.14 Specific provisions for monitoring opacity. (a) Coal-fired units and oil-fired units. The owner or operator shall meet the general... 40 Protection of Environment 17 2014-07-01 2014-07-01 false Specific provisions for monitoring...

  8. 40 CFR 75.14 - Specific provisions for monitoring opacity.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... PROGRAMS (CONTINUED) CONTINUOUS EMISSION MONITORING Monitoring Provisions § 75.14 Specific provisions for monitoring opacity. (a) Coal-fired units and oil-fired units. The owner or operator shall meet the general... 40 Protection of Environment 16 2011-07-01 2011-07-01 false Specific provisions for monitoring...

  9. 40 CFR 75.14 - Specific provisions for monitoring opacity.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... PROGRAMS (CONTINUED) CONTINUOUS EMISSION MONITORING Monitoring Provisions § 75.14 Specific provisions for monitoring opacity. (a) Coal-fired units and oil-fired units. The owner or operator shall meet the general... 40 Protection of Environment 17 2012-07-01 2012-07-01 false Specific provisions for monitoring...

  10. 40 CFR 75.14 - Specific provisions for monitoring opacity.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... PROGRAMS (CONTINUED) CONTINUOUS EMISSION MONITORING Monitoring Provisions § 75.14 Specific provisions for monitoring opacity. (a) Coal-fired units and oil-fired units. The owner or operator shall meet the general... 40 Protection of Environment 17 2013-07-01 2013-07-01 false Specific provisions for monitoring...

  11. LENS: Light Transport

    NASA Astrophysics Data System (ADS)

    Yokley, Zachary

    2013-04-01

    The LENS detector uses an optically segmented 3D lattice, a scintillation lattice (SL), that channels light via total internal reflection from a scintillation event down channels parallel to the 3 primary Cartesian axes to the edge of the detector. This unique design provides spatial and temporal resolution required to distinguish the internal background of ^115In from the neutrino signal. Optical segmentation is achieved with Teflon films. Currently a 400 liter prototype, miniLENS, is being developed to demonstrate the internal background rejection techniques needed for LENS. This requires that miniLENS be shielded from external backgrounds from the surrounding materials and the photomultiplier tubes (PMTs). This shielding is provided by a water tank that surrounds miniLENS. In order to retain the channel information and separate the PMTs from the detector the LENS collaboration has developed light guides (LGs) made from multilayer films. These LGs transport light both by total internal and specular reflection providing an efficient means of coupling the SL through the water shield to the PMTs outside the water tank. This talk will discuss light transport in the SL as well as the design and construction of the LGs in the context of miniLENS.

  12. Bilateral ring-shaped intrastromal opacities after corneal cross-linking for keratoconus.

    PubMed

    Camesasca, Fabrizio I; Vinciguerra, Paolo; Seiler, Theo

    2011-12-01

    To report a case of bilateral, ring-shaped, intrastromal corneal opacities after corneal cross-linking (CXL) for progressive keratoconus. A 21-year-old man with bilateral, progressive keratoconus underwent CXL with riboflavin 0.1% and ultraviolet A (UVA) light in the right eye and, 6 months later, in the left eye. One day after CXL, the right eye showed a sharply demarcated white ring in the corneal periphery. The ring involved the superficial stroma at 2 mm from the limbus, extended from 1 to 11 o'clock, and was 1.5-mm wide. Corneal topography showed marked central flattening. Six months after treatment, a residual, faint, ring-shaped opacity remained, with a decrease in corneal ectasia. Cross-linking was then performed in the left eye. Different ultraviolet devices were used in the two eyes. On postoperative day 1, the left eye also showed a white ring of stromal opacity. Scheimpflug imaging showed corneal stromal contraction in the zone of whitening. At final examination, >1 year after surgery, corrected visual acuity was 0.00 logMAR with cylinder of 2.00 diopters in both eyes. The bilateral intrastromal corneal changes were innocuous in the long-term, with preservation of good visual acuity and successful stabilization of progressive keratoconus.

  13. Plasticity for axolotl lens regeneration is associated with age‐related changes in gene expression

    PubMed Central

    Sousounis, Konstantinos; Athippozhy, Antony T.; Voss, S. Randal

    2014-01-01

    Abstract Mexican axolotls lose potential for lens regeneration 2 weeks after hatching. We used microarrays to identify differently expressed genes before and after this critical time, using RNA isolated from iris. Over 3700 genes were identified as differentially expressed in response to lentectomy between young (7 days post‐hatching) and old (3 months post‐hatching) axolotl larvae. Strikingly, many of the genes were only expressed in the early or late iris. Genes that were highly expressed in young iris significantly enriched electron transport chain, transcription, metabolism, and cell cycle gene ontologies, all of which are associated with lens regeneration. In contrast, genes associated with cellular differentiation and tissue maturation were uniquely expressed in old iris. Many of these expression differences strongly suggest that young and old iris samples were collected before and after the spleen became developmentally competent to produce and secrete cells with humoral and innate immunity functions. Our study establishes the axolotl as a powerful model to investigate age‐related cellular differentiation and immune system ontogeny within the context of tissue regeneration. PMID:27499863

  14. Converging or Diverging Lens?

    ERIC Educational Resources Information Center

    Branca, Mario

    2013-01-01

    Why does a lens magnify? Why does it shrink objects? Why does this happen? The activities that we propose here are useful in helping us to understand how lenses work, and they show that the same lens can have different magnification capabilities. A converging lens can also act as a diverging lens. (Contains 4 figures.)

  15. The Rosseland Mean Opacity in Dense Plasmas

    NASA Astrophysics Data System (ADS)

    van Horn, H. M.

    1992-05-01

    In post-main-sequence phases of stellar evolution, densities in the interiors of stars become large enough so that hbar omega_p /kT>1, where omega_p is the electron plasma frequency. The plasma is thus a strongly dispersive medium at frequencies near the peak of the Planck function, and only photons with frequencies omega >omega_p can propagate in the plasma. These effects must be taken into account in computing radiative transfer in stellar interiors. Here I first identify several late evolutionary stages in which these effects may be significant. Then I use the formalism Harris 1965 has developed to treat radiative transfer in a dispersive medium in order to derive the resulting modification of the Rosseland mean opacity kappa_R . The resulting expression is the same as that presented (without a full derivation) by Aharony & Opher 1979, who interpreted the frequency-dependent absorption coefficient kappa_ ω as that in vacuo. However, the absorption coefficient in a plasma scales from that in vacuum according to the relation kappa_ ω=n_ω(-1) kappa_ ω((vac)) (Bekefi 1966, p. 52), where n_ω equiv (kc/omega ) = [1-(omega_p (2/) omega (2)right ](1/2)) is the index of refraction of the plasma. With this correction, we find the Rosseland mean opacity to be given by the expression {1\\over \\kappa_R}={{\\int_{\\omega_p}^{\\infty} {n_{\\omega}^3 \\over \\kappa_{\\omega}^{(vac)}}{partial B_{\\omega} \\over partial T} \\bigg|_{\\omega} d\\omega} \\over{\\int_0^{\\infty}{partial B_{\\omega} \\over partial T} \\bigg|_{\\omega} d\\omega}}. This research has been supported in part by NASA grant NAGW-2444 and in part by NSF grant AST 91-15132. \\centerline{References} Aharony, U., and Opher, R. 1979, A&A, 79, 27. Bekefi, G. 1966, Radiation Processes in Plasmas, (John Wiley & Sons, Inc.: New York). Harris, E. G. 1965, Phys. Rev., 138, B479.

  16. 50. (no plate) Lens, lens pedestal, mercury float, drawing # ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    50. (no plate) Lens, lens pedestal, mercury float, drawing # 3101, sheet 1 of 2. Approved April 6, 1928. - Block Island Southeast Light, Spring Street & Mohegan Trail at Mohegan Bluffs, New Shoreham, Washington County, RI

  17. 68 Ga-PSMA-PET/CT for the evaluation of pulmonary metastases and opacities in patients with prostate cancer.

    PubMed

    Damjanovic, Jonathan; Janssen, Jan-Carlo; Furth, Christian; Diederichs, Gerd; Walter, Thula; Amthauer, Holger; Makowski, Marcus R

    2018-05-16

    The purpose of this study was to investigate the imaging properties of pulmonary metastases and benign opacities in 68 Ga-PSMA positron emission tomography (PET) in patients with prostate cancer (PC). 68 Ga-PSMA-PET/CT scans of 739 PC patients available in our database were evaluated retrospectively for lung metastases and non-solid focal pulmonary opacities. Maximum standardized uptake values (SUV max ) were assessed by two- and three-dimensional regions of interest (2D/3D ROI). Additionally CT features of the lesions, such as location, morphology and size were identified. Ninety-one pulmonary metastases and fourteen opacities were identified in 34 PC patients. In total, 66 PSMA-positive (72.5%) and 25 PSMA-negative (27.5%) metastases were identified. The mean SUV max of pulmonary opacities was 2.2±0.7 in 2D ROI and 2.4±0.8 in 3D ROI. The mean SUV max of PSMA-positive pulmonary metastases was 4.5±2.7 in 2D ROI and in 4.7±2.9 in 3D ROI; this was significantly higher than the SUV max of pulmonary opacities in both 2D and 3D ROI (p<0.001). The mean SUV max of PSMA-negative metastases was 1.0±0.5 in 2D ROI and 1.0±0.4 in 3D ROI, and significantly lower than that of the pulmonary opacities (p<0.001). A significant (p<0.05) weak linear correlation between size and 3D SUV max in lung metastases (ρ Spearman =0.207) was found. Based on the SUV max in 68 Ga-PSMA-PET alone, it was not possible to differentiate between pulmonary metastases and pulmonary opacities. The majority of lung metastases highly overexpressed PSMA, while a relevant number of metastases were PSMA-negative. Pulmonary opacities demonstrated a moderate tracer uptake, significantly lower than PSMA-positive lung metastases, yet significantly higher than PSMA-negative metastases.

  18. A conserved role of αA-crystallin in the development of the zebrafish embryonic lens.

    PubMed

    Zou, Ping; Wu, Shu-Yu; Koteiche, Hanane A; Mishra, Sanjay; Levic, Daniel S; Knapik, Ela; Chen, Wenbiao; Mchaourab, Hassane S

    2015-09-01

    αA- and αB-crystallins are small heat shock proteins that bind thermodynamically destabilized proteins thereby inhibiting their aggregation. Highly expressed in the mammalian lens, the α-crystallins have been postulated to play a critical role in the maintenance of lens optical properties by sequestering age-damaged proteins prone to aggregation as well as through a multitude of roles in lens epithelial cells. Here, we have examined the role of α-crystallins in the development of the vertebrate zebrafish lens. For this purpose, we have carried out morpholino-mediated knockdown of αA-, αBa- and αBb-crystallin and characterized the gross morphology of the lens. We observed lens abnormalities, including increased reflectance intensity, as a consequence of the interference with expression of these proteins. These abnormalities were less frequent in transgenic zebrafish embryos expressing rat αA-crystallin suggesting a specific role of α-crystallins in embryonic lens development. To extend and confirm these findings, we generated an αA-crystallin knockout zebrafish line. A more consistent and severe lens phenotype was evident in maternal/zygotic αA-crystallin mutants compared to those observed by morpholino knockdown. The penetrance of the lens phenotype was reduced by transgenic expression of rat αA-crystallin and its severity was attenuated by maternal αA-crystallin expression. These findings demonstrate that the role of α-crystallins in lens development is conserved from mammals to zebrafish and set the stage for using the embryonic lens as a model system to test mechanistic aspects of α-crystallin chaperone activity and to develop strategies to fine-tune protein-protein interactions in aging and cataracts. Copyright © 2015 Elsevier Ltd. All rights reserved.

  19. Bacterial flora of the eye and contact lens. Cases during hydrogel lens wear.

    PubMed

    Callender, M G; Tse, L S; Charles, A M; Lutzi, D

    1986-03-01

    Bacteriological comparisons between the tear fluids of soft contact lens wearers and noncontact lens wearers indicate that there is an increase in the bacterial population in contact lens wearers but not a significant change in the varieties present. Differences between groups of contact lens wearers appear to depend on the method of disinfection used.

  20. Hohlraum modeling for opacity experiments on the National Ignition Facility

    NASA Astrophysics Data System (ADS)

    Dodd, E. S.; DeVolder, B. G.; Martin, M. E.; Krasheninnikova, N. S.; Tregillis, I. L.; Perry, T. S.; Heeter, R. F.; Opachich, Y. P.; Moore, A. S.; Kline, J. L.; Johns, H. M.; Liedahl, D. A.; Cardenas, T.; Olson, R. E.; Wilde, B. H.; Urbatsch, T. J.

    2018-06-01

    This paper discusses the modeling of experiments that measure iron opacity in local thermodynamic equilibrium (LTE) using laser-driven hohlraums at the National Ignition Facility (NIF). A previous set of experiments fielded at Sandia's Z facility [Bailey et al., Nature 517, 56 (2015)] have shown up to factors of two discrepancies between the theory and experiment, casting doubt on the validity of the opacity models. The purpose of the new experiments is to make corroborating measurements at the same densities and temperatures, with the initial measurements made at a temperature of 160 eV and an electron density of 0.7 × 1022 cm-3. The X-ray hot spots of a laser-driven hohlraum are not in LTE, and the iron must be shielded from a direct line-of-sight to obtain the data [Perry et al., Phys. Rev. B 54, 5617 (1996)]. This shielding is provided either with the internal structure (e.g., baffles) or external wall shapes that divide the hohlraum into a laser-heated portion and an LTE portion. In contrast, most inertial confinement fusion hohlraums are simple cylinders lacking complex gold walls, and the design codes are not typically applied to targets like those for the opacity experiments. We will discuss the initial basis for the modeling using LASNEX, and the subsequent modeling of five different hohlraum geometries that have been fielded on the NIF to date. This includes a comparison of calculated and measured radiation temperatures.

  1. Lid wiper microvascular responses as an indicator of contact lens discomfort

    PubMed Central

    Deng, Zhihong; Wang, Jianhua; Jiang, Hong; Fadli, Zohra; Liu, Che; Tan, Jia; Zhou, Jin

    2016-01-01

    Purpose To analyze quantitatively the alterations in the microvascular network of the upper tarsal conjunctiva, lid wiper, and bulbar conjunctiva relative to ocular discomfort after contact lens wear. Design A prospective, cross-over clinical study. Methods Functional slit-lamp biomicroscopy (FSLB) was used to image the microvascular network of the upper tarsal conjunctiva, lid wiper, and bulbar conjunctiva. The microvascular network was automatically segmented, and fractal analyses were performed to yield the fractal dimension (Dbox) that represented vessel density. Sixteen healthy subjects (nine female and seven male) with an average age of 35.5 ± 6.7 years old (mean ± standard deviation) were recruited. The right eye was imaged at 9 AM and 3 PM at the first visit (Day 1) when the subject was not wearing contact lenses. During the second visit (Day 2), the right eye was fit with a contact lens for 6 h. Microvascular imaging was performed before (at 9 AM) and after lens wear (at 3 PM). Ocular comfort was rated using a 50-point visual analogue scale before and after 6 h of lens wear, and its relationships with microvascular parameters were analyzed. Results There were no significant differences in Dbox among the upper tarsal conjunctiva, lid wiper, and bulbar conjunctiva among the measurements at 9 AM (Day 1 and Day 2) and 3 PM (Day 1) when the subjects were not wearing the lenses (P > 0.05), whereas after 6 h of lens wear, the microvascular network densities were increased in all three of these locations. Dbox of the lid wiper increased from 1.411 ± 0.116 to 1.548 ± 0.079 after 6 h of contact lens wear (P < 0.01). Dbox of the tarsal conjunctiva was 1.731 ± 0.026 at baseline and increased to 1.740 ± 0.030 (P < 0.05). Dbox of the bulbar conjunctiva increased from 1.587 ± 0.059 to 1.632 ± 0.060 (P < 0.001). The decrease in ocular discomfort was strongly related to the Dbox change in the lid wiper (r = 0.61, P < 0.05). There were no correlations between the

  2. [Clinical, morphological and molecular biological characteristics of the aging eye].

    PubMed

    Böhm, M R R; Thomasen, H; Parnitzke, F; Steuhl, K-P

    2017-02-01

    The physiological aging of the eye is associated with loss of visual function. Age-related changes of the eye can result in ophthalmological diseases. The aim of this article is to display morphological, histological and molecular biological alterations of the aging eye. A web-based search and review of the literature for aging of the visual system including cornea, lens, vitreous humor, retina, retinal pigment epithelium (RPE), choroidea and optic nerve were carried out. The most important results related to morphological, histological and molecular biological changes are summarized. Age-related, morphological alterations can be found in preretinal structures, e. g. cornea, lens and vitreous humor, as well as neuronal structures, such as the retina. In addition to negligible clinical signs of the aging eye, there are clinically relevant changes which can develop into pathological ophthalmological diseases. These transitions from age-related alterations to relevant ophthalmological diseases, e. g. age-related macular degeneration and glaucoma are continuous. An understanding of aging could provide predictive factors to detect the conversion of physiological aging into pathological conditions. The derivation of physiological markers or new approaches to detection and treatment of disease-related entities associated with the risk factor aging are desirable. Translational approaches in clinical and basic science are necessary to provide new therapeutic options for relevant ophthalmological diseases in the future.

  3. Lightweight, high-opacity Bible paper by fiber loading

    Treesearch

    Klaus Doelle; Oliver Heise; John H. Klungness; Said M. AbuBakr

    2000-01-01

    This paper has been prepared in order to discuss Fiber Loading™ for lightweight, high-opacity bible paper. Incorporating fillers within pulp fibers has been subject to research since 1960 (Green et al. 1962, Scallan et al. 1985, Allen et al. 1992). Fiber Loading™ is a method for manufacturing precipitated calcium carbonate (PCC) directly within the pulp processing...

  4. Optical integration of Pancharatnam-Berry phase lens and dynamical phase lens

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ke, Yougang; Liu, Yachao; Zhou, Junxiao

    In the optical system, most elements such as lens, prism, and optical fiber are made of silica glass. Therefore, integrating Pancharatnam-Berry phase elements into silica glass has potential applications in the optical system. In this paper, we take a lens, for example, which integrates a Pancharatnam-Berry phase lens into a conventional plano-convex lens. The spin states and positions of focal points can be modulated by controlling the polarization states of the incident beam. The proposed lens has a high transmission efficiency, and thereby acts as a simple and powerful tool to manipulate spin photons. Furthermore, the method can be convenientlymore » extended to the optical fiber and laser cavity, and may provide a route to the design of the spin-photonic devices.« less

  5. ANALYTICAL SOLUTIONS OF SINGULAR ISOTHERMAL QUADRUPOLE LENS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chu Zhe; Lin, W. P.; Yang Xiaofeng, E-mail: chuzhe@shao.ac.cn, E-mail: linwp@shao.ac.cn

    Using an analytical method, we study the singular isothermal quadrupole (SIQ) lens system, which is the simplest lens model that can produce four images. In this case, the radial mass distribution is in accord with the profile of the singular isothermal sphere lens, and the tangential distribution is given by adding a quadrupole on the monopole component. The basic properties of the SIQ lens have been studied in this Letter, including the deflection potential, deflection angle, magnification, critical curve, caustic, pseudo-caustic, and transition locus. Analytical solutions of the image positions and magnifications for the source on axes are derived. Wemore » find that naked cusps will appear when the relative intensity k of quadrupole to monopole is larger than 0.6. According to the magnification invariant theory of the SIQ lens, the sum of the signed magnifications of the four images should be equal to unity, as found by Dalal. However, if a source lies in the naked cusp, the summed magnification of the left three images is smaller than the invariant 1. With this simple lens system, we study the situations where a point source infinitely approaches a cusp or a fold. The sum of the magnifications of the cusp image triplet is usually not equal to 0, and it is usually positive for major cusps while negative for minor cusps. Similarly, the sum of magnifications of the fold image pair is usually not equal to 0 either. Nevertheless, the cusp and fold relations are still equal to 0 in that the sum values are divided by infinite absolute magnifications by definition.« less

  6. Contribution of the crystalline lens gradient refractive index to the accommodation amplitude in non-human primates: in vitro studies.

    PubMed

    Maceo, Bianca M; Manns, Fabrice; Borja, David; Nankivil, Derek; Uhlhorn, Stephen; Arrieta, Esdras; Ho, Arthur; Augusteyn, Robert C; Parel, Jean-Marie

    2011-11-30

    The purpose of this study was to determine the contribution of the gradient refractive index to the change in lens power in hamadryas baboon and cynomolgus monkey lenses during simulated accommodation in a lens stretcher. Thirty-six monkey lenses (1.4-14.1 years) and twenty-five baboon lenses (1.8-28.0 years) were stretched in discrete steps. At each stretching step, the lens back vertex power was measured and the lens cross-section was imaged with optical coherence tomography. The radii of curvature for the lens anterior and posterior surfaces were calculated for each step. The power of each lens surface was determined using refractive indices of 1.365 for the outer cortex and 1.336 for the aqueous. The gradient contribution was calculated by subtracting the power of the surfaces from the measured lens power. In all lenses, the contribution of the surfaces and gradient increased linearly with the amplitude of accommodation. The gradient contributes on average 65 ± 3% for monkeys and 66 ± 3% for baboons to the total power change during accommodation. When expressed in percent of the total power change, the relative contribution of the gradient remains constant with accommodation and age in both species. These findings are consistent with Gullstrand's intracapsular theory of accommodation.

  7. UVA Light-excited Kynurenines Oxidize Ascorbate and Modify Lens Proteins through the Formation of Advanced Glycation End Products

    PubMed Central

    Linetsky, Mikhail; Raghavan, Cibin T.; Johar, Kaid; Fan, Xingjun; Monnier, Vincent M.; Vasavada, Abhay R.; Nagaraj, Ram H.

    2014-01-01

    Advanced glycation end products (AGEs) contribute to lens protein pigmentation and cross-linking during aging and cataract formation. In vitro experiments have shown that ascorbate (ASC) oxidation products can form AGEs in proteins. However, the mechanisms of ASC oxidation and AGE formation in the human lens are poorly understood. Kynurenines are tryptophan oxidation products produced from the indoleamine 2,3-dioxygenase (IDO)-mediated kynurenine pathway and are present in the human lens. This study investigated the ability of UVA light-excited kynurenines to photooxidize ASC and to form AGEs in lens proteins. UVA light-excited kynurenines in both free and protein-bound forms rapidly oxidized ASC, and such oxidation occurred even in the absence of oxygen. High levels of GSH inhibited but did not completely block ASC oxidation. Upon UVA irradiation, pigmented proteins from human cataractous lenses also oxidized ASC. When exposed to UVA light (320–400 nm, 100 milliwatts/cm2, 45 min to 2 h), young human lenses (20–36 years), which contain high levels of free kynurenines, lost a significant portion of their ASC content and accumulated AGEs. A similar formation of AGEs was observed in UVA-irradiated lenses from human IDO/human sodium-dependent vitamin C transporter-2 mice, which contain high levels of kynurenines and ASC. Our data suggest that kynurenine-mediated ASC oxidation followed by AGE formation may be an important mechanism for lens aging and the development of senile cataracts in humans. PMID:24798334

  8. Temporal evolution of UV opacity and dust particle size at Gale Crater from MSL/REMS measurements

    NASA Astrophysics Data System (ADS)

    Vicente-Retortillo, Álvaro; Martinez, German; Renno, Nilton O.; Lemmon, Mark T.; Mason, Emily; De la Torre, Manuel

    2016-10-01

    A better characterization of the size, radiative properties and temporal variability of suspended dust in the Martian atmosphere is necessary to improve our understanding of the current climate of Mars. The REMS UV sensor onboard the Mars Science Laboratory (MSL) Curiosity rover has performed ground-based measurements of solar radiation in six different UV spectral bands for the first time on Mars.We developed a novel technique to retrieve dust opacity and particle size from REMS UV measurements. We use the electrical output current (TELRDR products) of the six photodiodes and the ancillary data (ADR products) to avoid inconsistencies found in the processed data (units of W/m2) when the solar zenith angle is above 30°. In addition, we use TELRDR and ADR data only in events during which the Sun is temporally blocked by the rover's masthead or mast to mitigate uncertainties associated to the degradation of the sensor due to the deposition of dust on it. Then we use a radiative transfer model with updated dust properties based on the Monte-Carlo method to retrieve the dust opacity and particle size.We find that the seasonal trend of UV opacity is consistent with opacity values at 880 nm derived from Mastcam images of the Sun, with annual maximum values in spring and in summer and minimum values in winter. The interannual variability is low, with two local maxima in mid-spring and mid-summer. Finally, dust particle size also varies throughout the year with typical values of the effective radius in the range between 0.5 and 2 μm. These variations in particle size occur in a similar way to those in dust opacity; the smallest sizes are found when the opacity values are the lowest.

  9. Computational Design of Short Pulse Laser Driven Iron Opacity Measurements at Stellar-Relevant Conditions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Martin, Madison E.

    Opacity is a critical parameter in the simulation of radiation transport in systems such as inertial con nement fusion capsules and stars. The resolution of current disagreements between solar models and helioseismological observations would bene t from experimental validation of theoretical opacity models. Overall, short pulse laser heated iron experiments reaching stellar-relevant conditions have been designed with consideration of minimizing tamper emission and optical depth effects while meeting plasma condition and x-ray emission goals.

  10. Non-LTE H2+ as the source of missing opacity in the solar atmosphere

    NASA Technical Reports Server (NTRS)

    Swamy, K. S. K.; Stecher, T. P.

    1974-01-01

    The population of the various vibrational levels of the H2+ molecule has been calculated from the consideration of formation and destruction mechanisms. The resulting population is used in calculating the total absorption due to H2+ and is compared with the other known sources of opacity at several optical depths of the solar atmosphere. It is shown that the absorption due to H2+ can probably account for the missing ultraviolet opacity in the solar atmosphere.

  11. Ultrasound liquid crystal lens

    NASA Astrophysics Data System (ADS)

    Shimizu, Yuki; Koyama, Daisuke; Fukui, Marina; Emoto, Akira; Nakamura, Kentaro; Matsukawa, Mami

    2018-04-01

    A variable-focus lens using a combination of liquid crystals and ultrasound is discussed. The lens uses a technique based on ultrasound vibration to control the molecular orientation of the liquid crystal. The lens structure is simple, with no mechanical moving parts and no transparent electrodes, which is helpful for device downsizing; the structure consists of a liquid crystal layer sandwiched between two glass substrates with a piezoelectric ring. The tens-of-kHz ultrasonic resonance flexural vibration used to excite the lens generates an acoustic radiation force on the liquid crystal layer to induce changes in the molecular orientation of the liquid crystal. The orientations of the liquid crystal molecules and the optical characteristics of the lens were investigated under ultrasound excitation. Clear optical images were observed through the lens, and the focal point could be controlled using the input voltage to the piezoelectric ring to give the lens its variable-focus action.

  12. Influence of the atmospheric opacity cycle on the near surface environment of Gale Crater on Mars

    NASA Astrophysics Data System (ADS)

    de la Torre Juarez, Manuel; Gomez-Elvira, Javier; Guzewich, Scott David; Lemmon, Mark T.; Martinez, German; Mason, Emily; Navarro, Sara; Newman, Claire E.; Smith, Michael D.; Retortillo, Alvaro de Vicente

    2016-10-01

    The Mars atmospheric dust changes the capacity of the atmosphere to absorb solar radiation or release outgoing thermal infrared radiation. This alters the atmospheric heat exchange fluxes and can interfere with the global circulation. The response of near surface pressure, temperature and winds has been characterized at the higher northern latitudes of 45 degree N at the Viking landing sites. The Rover Environmental Monitoring Station (REMS) on Curiosity allows a similar characterization at near-equatorial latitudes of 4.5 degree S. Using MCAM-880 nm opacities as a measure of local atmospheric dust load, we analyze the response of changes in surface variables measured by REMS and compare to those observed by Viking. As on Viking, diurnal and semidiurnal pressure tide amplitudes track very closely the atmospheric opacity and the mean daily pressure shows the increased wave activity. Temperature tides show a more complex response that combines its sensitivity to changes in dust and cloud opacities. Differences in UV opacities for the REMS set of finite spectral windows are explored during the dust and clear seasons.

  13. Mice deficient for the secreted glycoprotein SPARC/osteonectin/BM40 develop normally but show severe age-onset cataract formation and disruption of the lens.

    PubMed Central

    Gilmour, D T; Lyon, G J; Carlton, M B; Sanes, J R; Cunningham, J M; Anderson, J R; Hogan, B L; Evans, M J; Colledge, W H

    1998-01-01

    SPARC (secreted protein acidic and rich in cysteine, also known as osteonectin/BM40) is a secreted Ca2+-binding glycoprotein that interacts with a range of extracellular matrix molecules, including collagen IV. It is widely expressed during embryogenesis, and in vitro studies have suggested roles in the regulation of cell adhesion and proliferation, and in the modulation of cytokine activity. In order to analyse the function of this protein in vivo, the endogenous Sparc locus was disrupted by homologous recombination in murine embryonic stem cells. SPARC-deficient mice (Sparctm1Cam) appear normal and fertile until around 6 months of age, when they develop severe eye pathology characterized by cataract formation and rupture of the lens capsule. The first sign of lens pathology occurs in the equatorial bow region where vacuoles gradually form within differentiating epithelial cells and fibre cells. The lens capsule, however, shows no qualitative changes in the major basal lamina proteins laminin, collagen IV, perlecan or entactin. These mice are an excellent resource for further studies on how SPARC affects cell behaviour in vivo. PMID:9524110

  14. Influence of Gravity on Ocular Lens Position.

    PubMed

    Lister, Lucas J; Suheimat, Marwan; Verkicharla, Pavan K; Mallen, Edward A H; Atchison, David A

    2016-04-01

    We determined whether human ocular lens position is influenced by gravity. Anterior chamber depth (ACD) and lens thickness (LT) were determined with a Haag-Streit Lenstar LS900 for right eyes of participants in two age groups, with a young group of 13 participants aged 18 to 21 years (mean, 21 years; SD, 1 year) and an older group of 10 participants aged 50 to 63 years (mean, 58 years; SD, 4 years). There were two sessions for each participant separated by at least 48 hours, with one session for the usual upright head position and one session for a downwards head position. In a session, testing was done for minimum accommodation followed by testing at maximum accommodation. A drop of 2% pilocarpine nitrate was instilled, and testing was repeated after 30 minutes under minimum and maximum accommodation conditions. Gravity, manipulated through head posture, affected ACD for young adult and older adult groups but mean effects were only small, ranging from 0.04 to 0.12 mm, and for the older group required the instillation of an accommodation-stimulating drug. Gravity had a weakly significant effect on LT for the young group without accommodation or a drug, but the effect was small at 0.04 ± 0.06 mm (mean ± SD, P = 0.04). There is a small but real effect of gravity on crystalline lens position, manifested as reduction in ACD at high levels of accommodative effort with the head in a downwards position. This provides evidence of the ability of zonules to slacken during strong accommodation.

  15. A note on the contribution of multi-photon processes to radiative opacity

    NASA Astrophysics Data System (ADS)

    Pain, Jean-Christophe

    2018-03-01

    Recently, Bailey et al. performed iron opacity measurements on the Z machine at Sandia National Laboratory in conditions close to the ones of the base of the convective zone of the Sun. Such experiments have raised questions about the physical models commonly used in opacity codes. To understand the discrepancy between experiment and theory, More et al. investigated the role of two-photon processes. In the present work we show, by simple estimate and using hydrogenic formulas, that due to the intensity of the backlight radiation seen by the sample, such processes are likely to play an important role only for highly excited states.

  16. Gradient parameter and axial and field rays in the gradient-index crystalline lens model

    NASA Astrophysics Data System (ADS)

    Pérez, M. V.; Bao, C.; Flores-Arias, M. T.; Rama, M. A.; Gómez-Reino, C.

    2003-09-01

    Gradient-index models of the human lens have received wide attention in optometry and vision sciences for considering how changes in the refractive index profile with age and accommodation may affect refractive power. This paper uses the continuous asymmetric bi-elliptical model to determine gradient parameter and axial and field rays of the human lens in order to study the paraxial propagation of light through the crystalline lens of the eye.

  17. Capsule implosions for continuum x-ray backlighting of opacity samples at the National Ignition Facility

    NASA Astrophysics Data System (ADS)

    Opachich, Y. P.; Heeter, R. F.; Barrios, M. A.; Garcia, E. M.; Craxton, R. S.; King, J. A.; Liedahl, D. A.; McKenty, P. W.; Schneider, M. B.; May, M. J.; Zhang, R.; Ross, P. W.; Kline, J. L.; Moore, A. S.; Weaver, J. L.; Flippo, K. A.; Perry, T. S.

    2017-06-01

    Direct drive implosions of plastic capsules have been performed at the National Ignition Facility to provide a broad-spectrum (500-2000 eV) X-ray continuum source for X-ray transmission spectroscopy. The source was developed for the high-temperature plasma opacity experimental platform. Initial experiments using 2.0 mm diameter polyalpha-methyl styrene capsules with ˜20 μm thickness have been performed. X-ray yields of up to ˜1 kJ/sr have been measured using the Dante multichannel diode array. The backlighter source size was measured to be ˜100 μm FWHM, with ˜350 ps pulse duration during the peak emission stage. Results are used to simulate transmission spectra for a hypothetical iron opacity sample at 150 eV, enabling the derivation of photometrics requirements for future opacity experiments.

  18. Formation of Planetary Populations I: Metallicity & Envelope Opacity Effects

    NASA Astrophysics Data System (ADS)

    Alessi, Matthew; Pudritz, Ralph E.

    2018-05-01

    We present a comprehensive body of simulations of the formation of exoplanetary populations that incorporate the role of planet traps in slowing planetary migration. The traps we include in our model are the water ice line, the disk heat transition, and the dead zone outer edge. We reduce our model parameter set to two physical parameters: the opacity of the accreting planetary atmospheres (κenv) and a measure of the efficiency of planetary accretion after gap opening (fmax). We perform planet population synthesis calculations based on the initial observed distributions of host star and disk properties - their disk masses, lifetimes, and stellar metallicities. We find the frequency of giant planet formation scales with disk metallicity, in agreement with the observed Jovian planet frequency-metallicity relation. We consider both X-ray and cosmic ray disk ionization models, whose differing ionization rates lead to different dead zone trap locations. In both cases, Jovian planets form in our model out to 2-3 AU, with a distribution at smaller radii dependent on the disk ionization source and the setting of envelope opacity. We find that low values of κenv (0.001-0.002 cm2 g-1) and X-ray disk ionization are necessary to obtain a separation between hot Jupiters near 0.1 AU, and warm Jupiters outside 0.6 AU, a feature present in the data. Our model also produces a large number of super Earths, but the majority are outside of 2 AU. As our model assumes a constant dust to gas ratio, we suggest that radial dust evolution must be taken into account to reproduce the observed super Earth population.

  19. [Comparative analysis of visual function and the quality of life index with eyeglasses or a progressive contact lens].

    PubMed

    Sant'Anna, Neusa Vidal; Schor, Paulo; Lipener, César; Uras, Ricardo

    2006-01-01

    To compare the visual function and the answers to a questionnaire of quality of life of patients wearing a progressive contact lens or eyeglasses. The Focus Progressive contact lens had been fitted in 35 patients with far visual acuity with progressive-addition eyeglasses equal to zero (log MAR) and near J1 (Jaeger). The far and near visual acuities and the measurement of contrast sensitivity were compared when the patients were wearing the eyeglasses or the contact lens and the patients' results of the scores of the quality of life questionnaire (NEI VFQ-25) were analyzed statistically considering the type of ametropy and the age. The far and near visual acuities and the contrast sensitivity measurement were worse with the contact lens than with eyeglasses. The answers to the questionnaire did not differ when were comparing the same patients wearing eyeglasses or contact lens, no matter the type of ametropy. The myopic and the hyperopic subgroups had worse answers to the quality of life questionnaire when corrected with the contact lens than with eyeglasses, both with age equal to or less than their median. The visual function was worse with the contact lens. The type of ametropy did not influence the answers to the quality of life questionnaire considering the optical correction, but age did.

  20. Anterior Lens Capsule and Iris Thicknesses in Pseudoexfoliation Syndrome.

    PubMed

    Batur, Muhammed; Seven, Erbil; Tekin, Serek; Yasar, Tekin

    2017-11-01

    The aim of this study was to evaluate anatomic properties of the lens capsule and iris by anterior segment optical coherence tomography (AS-OCT) in patients with pseudoexfoliation (PEX). This prospective study included 62 eyes of 62 patients with PEX syndrome and 43 eyes of 43 age- and gender-matched controls. All subjects underwent full ophthalmologic examinations including AS-OCT. Pupillary diameter, midperipheral stromal iris thickness, central and temporal lens capsule thicknesses, and peripheral pseudoexfoliation material thickness on the anterior lens capsule surface were measured and recorded. Mean age was 66.8 ± 9.3 years in the PEX group and 65.5 ± 8.9 years in the control group (p = 0.44). The PEX group consisted of 62 patients: 38 men (61.3%) and 24 women (38.7%); the control group included 43 subjects: 25 men (58.1%) and 18 women (41.9%). Pupillary diameter after pharmacologic mydriasis was 21% smaller in the PEX group than controls. Mean midperipheral iris thickness was 36 ± 7.2 μm (7.8%) thinner in the PEX group than that of control group (p = 0.047). The central anterior capsule was a mean of 3.40 ± 0.51 μm (18%) thicker in the PEX group compared to the control group (p = 0.0001). The temporal anterior lens capsule was a mean of 0.17 ± 0.15 μm thicker in the PEX group compared to the control group (p = 0.81). With high-resolution OCT imaging, it has become possible to evaluate the anterior lens capsule without histologic examination and demonstrate that it is thicker than normal in PEX patients.