Sample records for air gun source

  1. Water gun vs air gun: A comparison

    USGS Publications Warehouse

    Hutchinson, D.R.; Detrick, R. S.

    1984-01-01

    The water gun is a relatively new marine seismic sound source that produces an acoustic signal by an implosive rather than explosive mechanism. A comparison of the source characteristics of two different-sized water guns with those of conventional air guns shows the the water gun signature is cleaner and much shorter than that of a comparable-sized air gun: about 60-100 milliseconds (ms) for an 80-in3. (1.31-liter (I)) water gun compared with several hundred ms for an 80-in3. (1.31-1) air gun. The source spectra of water guns are richer in high frequencies (>200 Hz) than are those of air guns, but they also have less energy than those of air guns at low frequencies. A comparison between water gun and air gun reflection profiles in both shallow (Long Island Sound)-and deep (western Bermuda Rise)-water settings suggests that the water gun offers a good compromise between very high resolution, limited penetration systems (e.g. 3.5-kHz profilers and sparkers) and the large volume air guns and tuned air gun arrays generally used where significant penetration is required. ?? 1984 D. Reidel Publishing Company.

  2. Characteristic Analysis of Air-gun Source Wavelet based on the Vertical Cable Data

    NASA Astrophysics Data System (ADS)

    Xing, L.

    2016-12-01

    Air guns are important sources for marine seismic exploration. Far-field wavelets of air gun arrays, as a necessary parameter for pre-stack processing and source models, plays an important role during marine seismic data processing and interpretation. When an air gun fires, it generates a series of air bubbles. Similar to onshore seismic exploration, the water forms a plastic fluid near the bubble; the farther the air gun is located from the measurement, the more steady and more accurately represented the wavelet will be. In practice, hydrophones should be placed more than 100 m from the air gun; however, traditional seismic cables cannot meet this requirement. On the other hand, vertical cables provide a viable solution to this problem. This study uses a vertical cable to receive wavelets from 38 air guns and data are collected offshore Southeast Qiong, where the water depth is over 1000 m. In this study, the wavelets measured using this technique coincide very well with the simulated wavelets and can therefore represent the real shape of the wavelets. This experiment fills a technology gap in China.

  3. Numerical simulation of seismic wave propagation from land-excited large volume air-gun source

    NASA Astrophysics Data System (ADS)

    Cao, W.; Zhang, W.

    2017-12-01

    The land-excited large volume air-gun source can be used to study regional underground structures and to detect temporal velocity changes. The air-gun source is characterized by rich low frequency energy (from bubble oscillation, 2-8Hz) and high repeatability. It can be excited in rivers, reservoirs or man-made pool. Numerical simulation of the seismic wave propagation from the air-gun source helps to understand the energy partitioning and characteristics of the waveform records at stations. However, the effective energy recorded at a distance station is from the process of bubble oscillation, which can not be approximated by a single point source. We propose a method to simulate the seismic wave propagation from the land-excited large volume air-gun source by finite difference method. The process can be divided into three parts: bubble oscillation and source coupling, solid-fluid coupling and the propagation in the solid medium. For the first part, the wavelet of the bubble oscillation can be simulated by bubble model. We use wave injection method combining the bubble wavelet with elastic wave equation to achieve the source coupling. Then, the solid-fluid boundary condition is implemented along the water bottom. And the last part is the seismic wave propagation in the solid medium, which can be readily implemented by the finite difference method. Our method can get accuracy waveform of land-excited large volume air-gun source. Based on the above forward modeling technology, we analysis the effect of the excited P wave and the energy of converted S wave due to different water shapes. We study two land-excited large volume air-gun fields, one is Binchuan in Yunnan, and the other is Hutubi in Xinjiang. The station in Binchuan, Yunnan is located in a large irregular reservoir, the waveform records have a clear S wave. Nevertheless, the station in Hutubi, Xinjiang is located in a small man-made pool, the waveform records have very weak S wave. Better understanding of

  4. Advance in exploring the subsurface temporal evolution with Air-gun artificial source of Fujian, China

    NASA Astrophysics Data System (ADS)

    Yandan, H.; Jun, L.; Jin, X.; Tianyun, W.

    2017-12-01

    Geological disasters occur with the stress changes of subsurface medium. Since the stress changes slowly in the deep earth where only seismic wave can reach, monitoring the changes with repeatable seismic sources, ambient seismic noise and artificial sources has become a hot topic in seismology. The Fujian Earthquake Agency successfully constructed the Air-gun artificial source system and carried out over 6000 shots in six reservoirs. The correlation coefficient of signals can reach up to 0.99. Besides an excellent source, high recognition ability of seismic wave changes is required. It is common to use time delay estimation method based on cross-correlation to recognize the velocity changes. We investigate the accuracy of time delay detection of Air-gun source signals. Suppose that the medium does not change in a short time, we changed the explosion conditions of the air-gun array and recognized the subtle changes of signals by the time delay estimation method: (1) we changed the excitation depth from 8m to 30m, and found that the arriving time of bubble pulses advanced nearly 90ms. The results are quite consistent with the records of the OBS on the bottom of reservoir; (2) we changed the firing pressure from 800Psi to 2000Psi, and found that the bubble pulses were quite different but now we don't have any suitable numerical model to fit the changes; (3) we changed the excitation position of the air-gun, and divided the changed distance between the Air-gun and the near-shore seismograph by the corresponding changed travelling time. Then we got a velocity of 1.5km/s, which equals to the sound speed in water; (4) we controlled the microsecond of explosion moment from 0ms to 9ms, and counted the time delays of waveforms. Results are quite consistent with the theoretical value; (5) we changed the explosion mode, and quantitatively recognized the 0.1ms changes of the signal travel time. Our experiments show that the method is of high precision that can recognize the

  5. Determining the behavioural dose-response relationship of marine mammals to air gun noise and source proximity.

    PubMed

    Dunlop, Rebecca A; Noad, Michael J; McCauley, Robert D; Scott-Hayward, Lindsay; Kniest, Eric; Slade, Robert; Paton, David; Cato, Douglas H

    2017-08-15

    The effect of various anthropogenic sources of noise (e.g. sonar, seismic surveys) on the behaviour of marine mammals is sometimes quantified as a dose-response relationship, where the probability of an animal behaviourally 'responding' (e.g. avoiding the source) increases with 'dose' (or received level of noise). To do this, however, requires a definition of a 'significant' response (avoidance), which can be difficult to quantify. There is also the potential that the animal 'avoids' not only the source of noise but also the vessel operating the source, complicating the relationship. The proximity of the source is an important variable to consider in the response, yet difficult to account for given that received level and proximity are highly correlated. This study used the behavioural response of humpback whales to noise from two different air gun arrays (20 and 140 cubic inch air gun array) to determine whether a dose-response relationship existed. To do this, a measure of avoidance of the source was developed, and the magnitude (rather than probability) of this response was tested against dose. The proximity to the source, and the vessel itself, was included within the one-analysis model. Humpback whales were more likely to avoid the air gun arrays (but not the controls) within 3 km of the source at levels over 140 re. 1 µPa 2  s -1 , meaning that both the proximity and the received level were important factors and the relationship between dose (received level) and response is not a simple one. © 2017. Published by The Company of Biologists Ltd.

  6. Controlled-Temperature Hot-Air Gun

    NASA Technical Reports Server (NTRS)

    Munoz, M. C.

    1986-01-01

    Materials that find applications in wind tunnels first tested in laboratory. Hot-Air Gun differs from commercial units in that flow rate and temperature monitored and controlled. With typical compressed-airsupply pressure of 25 to 38 psi (170 to 260 kPa), flow rate and maximum temperature are 34 stdft3/min (0.96 stdm3/min) and 1,090 degrees F (590 degrees C), respectively. Resembling elaborate but carefully regulated hot-air gun, setup used to apply blasts of air temperatures above 1,500 degrees F (815 degrees C) to test specimens.

  7. ECR ion source with electron gun

    DOEpatents

    Xie, Z.Q.; Lyneis, C.M.

    1993-10-26

    An Advanced Electron Cyclotron Resonance ion source having an electron gun for introducing electrons into the plasma chamber of the ion source is described. The ion source has a injection enclosure and a plasma chamber tank. The plasma chamber is defined by a plurality of longitudinal magnets. The electron gun injects electrons axially into the plasma chamber such that ionization within the plasma chamber occurs in the presence of the additional electrons produced by the electron gun. The electron gun has a cathode for emitting electrons therefrom which is heated by current supplied from an AC power supply while bias potential is provided by a bias power supply. A concentric inner conductor and outer conductor carry heating current to a carbon chuck and carbon pusher which hold the cathode in place and also heat the cathode. In the Advanced Electron Cyclotron Resonance ion source, the electron gun replaces the conventional first stage used in prior electron cyclotron resonance ion generators. 5 figures.

  8. ECR ion source with electron gun

    DOEpatents

    Xie, Zu Q.; Lyneis, Claude M.

    1993-01-01

    An Advanced Electron Cyclotron Resonance ion source (10) having an electron gun (52) for introducing electrons into the plasma chamber (18) of the ion source (10). The ion source (10) has a injection enclosure (12) and a plasma chamber tank (14). The plasma chamber (18) is defined by a plurality of longitudinal magnets (16). The electron gun (52) injects electrons axially into the plasma chamber (18) such that ionization within the plasma chamber (18) occurs in the presence of the additional electrons produced by the electron gun (52). The electron gun (52) has a cathode (116) for emitting electrons therefrom which is heated by current supplied from an AC power supply (96) while bias potential is provided by a bias power supply (118). A concentric inner conductor (60) and Outer conductor (62) carry heating current to a carbon chuck (104) and carbon pusher (114) Which hold the cathode (116) in place and also heat the cathode (16). In the Advanced Electron Cyclotron Resonance ion source (10), the electron gun (52) replaces the conventional first stage used in prior art electron cyclotron resonance ion generators.

  9. Compressed air noise reductions from using advanced air gun nozzles in research and development environments.

    PubMed

    Prieve, Kurt; Rice, Amanda; Raynor, Peter C

    2017-08-01

    The aims of this study were to evaluate sound levels produced by compressed air guns in research and development (R&D) environments, replace conventional air gun models with advanced noise-reducing air nozzles, and measure changes in sound levels to assess the effectiveness of the advanced nozzles as engineering controls for noise. Ten different R&D manufacturing areas that used compressed air guns were identified and included in the study. A-weighted sound level and Z-weighted octave band measurements were taken simultaneously using a single instrument. In each area, three sets of measurements, each lasting for 20 sec, were taken 1 m away and perpendicular to the air stream of the conventional air gun while a worker simulated typical air gun work use. Two different advanced noise-reducing air nozzles were then installed. Sound level and octave band data were collected for each of these nozzles using the same methods as for the original air guns. Both of the advanced nozzles provided sound level reductions of about 7 dBA, on average. The highest noise reductions measured were 17.2 dBA for one model and 17.7 dBA for the other. In two areas, the advanced nozzles yielded no sound level reduction, or they produced small increases in sound level. The octave band data showed strong similarities in sound level among all air gun nozzles within the 10-1,000 Hz frequency range. However, the advanced air nozzles generally had lower noise contributions in the 1,000-20,000 Hz range. The observed decreases at these higher frequencies caused the overall sound level reductions that were measured. Installing new advanced noise-reducing air nozzles can provide large sound level reductions in comparison to existing conventional nozzles, which has direct benefit for hearing conservation efforts.

  10. Armored umbilical apparatus for towing a marine seismic air gun sub array

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Burrage, E.C.

    1985-06-25

    An armored umbilical and termination housing is disclosed for towing a sub-array of seismic air guns used in marine seismic surveying comprising a single air hose for supplying all the high pressure air to the individual air guns surrounded by all the electrical control cables needed to operate the air guns in the sub-array. Protective coatings are applied around the electrical control cables and stress members for carrying the load of towing the sub-array are incorporated within the umbilical. A termination housing is provided on the end of the umbilical for terminating the single air hose and all the electricalmore » control lines to common connectors so that individual electrical control lines and air hoses can run from the termination housing to each individual air gun in the sub-array. Air shut off valves are provided so that the high pressure air can be shut off to the individual air guns within the sub-array remotely from the survey vessel.« less

  11. Design of 50MM Powder to Air to Light Gas Gun Converter

    DTIC Science & Technology

    2008-06-01

    AFRL-RW-EG-TR-2008-7088 Design of 50MM Powder to Air or Light Gas Gun Converter Justin Chiasson, Matthew Hohenshutz, Jason Picone and Daniel...Final (September 2007-May 2008 4. TITLE AND SUBTITLE Sa. CONTRACT NUMBER 5b. GRANT NUMBER DESIGN OF 50MM POWDER TO AIR OR LIGHT GAS GUN CONVERTER...objectives and progress of the air gun project. The main objective is to design an air or light gas gun to launch a 1 kg projectile up to 2000 ft/s. An

  12. Broadband spectra of seismic survey air-gun emissions, with reference to dolphin auditory thresholds.

    PubMed

    Goold, J C; Fish, P J

    1998-04-01

    Acoustic emissions from a 2120 cubic in air-gun array were recorded through a towed hydrophone assembly during an oil industry 2-D seismic survey off the West Wales Coast of the British Isles. Recorded seismic pulses were sampled, calibrated, and analyzed post-survey to investigate power levels of the pulses in the band 200 Hz-22 kHz at 750-m, 1-km, 2.2-km, and 8-km range from source. At 750-m range from source, seismic pulse power at the 200-Hz end of the spectrum was 140 dB re: 1 microPa2/Hz, and at the 20-kHz end of the spectrum seismic pulse power was 90 dB re: 1 microPa2/Hz. Although the background noise levels of the seismic recordings were far in excess of ambient, due to the proximity of engine, propeller, and flow sources of the ship towing the hydrophone, seismic power dominated the entire recorded bandwidth of 200 Hz-22 kHz at ranges of up to 2 km from the air-gun source. Even at 8-km range seismic power was still clearly in excess of the high background noise levels up to 8 kHz. Acoustic observations of common dolphins during preceding seismic surveys suggest that these animals avoided the immediate vicinity of the air-gun array while firing was in progress, i.e., localized disturbance occurred during seismic surveying. Although a general pattern of localized disturbance is suggested, one specific observation revealed that common dolphins were able to tolerate the seismic pulses at 1-km range from the air-gun array. Given the high broadband seismic pulse power levels across the entire recorded bandwidth, and known auditory thresholds for several dolphin species, we consider such seismic emissions to be clearly audible to dolphins across a bandwidth of tens on kilohertz, and at least out to 8-km range.

  13. Air-gun signature modelling considering the influence of mechanical structure factors

    NASA Astrophysics Data System (ADS)

    Li, Guofa; Liu, Zhao; Wang, Jianhua; Cao, Mingqiang

    2014-04-01

    In marine seismic prospecting, as the air-gun array is usually composed of different types of air-guns, the signature modelling of different air-guns is particularly important to the array design. Different types of air-guns have different mechanical structures, which directly or indirectly affect the signatures. In order to simulate the influence of the mechanical structure, five parameters—the throttling constant, throttling power law exponent, mass release efficiency, fluid viscosity and heat transfer coefficient—are used in signature modelling. Through minimizing the energy relative error between the simulated and the measured signatures by the simulated annealing method, the five optimal parameters can be estimated. The method is tested in a field experiment, and the consistency between the simulated and the measured signatures is improved with the optimal parameters.

  14. Gun Violence Following Inpatient Psychiatric Treatment: Offense Characteristics, Sources of Guns, and Number of Victims.

    PubMed

    Kivisto, Aaron J

    2017-10-01

    This study presents data on the relative contribution to gun violence by people with a history of inpatient psychiatric treatment and on federal efforts to deter presumptively dangerous persons from obtaining firearms, information useful for analyzing the potential public health benefits of gun policies targeting people with serious mental illness. The study also estimates the reduction in gun violence victims that would be expected if individuals with a previous psychiatric hospitalization were prohibited from purchasing firearms. Data from 838 violent gun offenders from a nationally representative sample of state prison inmates were analyzed. Those with and without a history of psychiatric hospitalization were compared on a range of offense characteristics, including relationship to the victim, number of victims, location of the offense, and source of firearms. Inmates with a history of hospitalization constituted 12% of all violent gun offenders and accounted for 13% of the sample's victims. They were less likely than those without a previous hospitalization to victimize strangers (odds ratio=.52) and were no more likely to commit gun violence in public or to have multiple victims. Among those with previous hospitalizations, 78% obtained guns from sources not subject to federal background checks. Of the total 1,041 victims of gun violence, only 3% were victimized by participants with a history of hospitalization who obtained guns from currently regulated sources. Prohibiting all individuals with a history of psychiatric hospitalization from purchasing firearms, absent expanded background checks, was estimated to reduce the number of gun violence victims by only 3%.

  15. Evaluation of high frequency ghost cavitation emissions for two different seismic air-gun arrays using numerical modelling

    NASA Astrophysics Data System (ADS)

    Khodabandeloo, Babak; Landrø, Martin

    2017-04-01

    Sound is deployed by marine mammals for variety of vital purposes such as finding food, communication, echolocation, etc. On the other hand human activities generate underwater noise. One major type of acoustic source is marine seismic acquisition which is carried out to image layers beneath the seabed exploiting reflected acoustic and elastic waves. Air-gun arrays are the most common and efficient marine seismic sources. Field measurements using broad band hydrophones have revealed that acoustic energies emitted by air-gun arrays contains frequencies from a few Hz up to tens of kHz. Frequencies below 200 Hz benefit seismic imaging and the rest is normally considered as wasted energy. On the other hand, the high frequency range (above 200 Hz) overlaps with hearing curves of many marine mammals and especially toothed whales and may have an impact on their behavior. A phenomenon called ghost cavitation is recently recognized to be responsible for a major part of these high frequencies (> 5 kHz). Acoustic pressure waves of individual air guns reflected from sea surface can cause the hydrostatic pressure to drop towards zero close to the source array. In these regions there is a high probability for water vapor cavity growth and subsequent collapse. We have simulated ghost cavitation cloud using numerical modelling and the results are validated by comparing with field measurements. The model is used to compare the amount of high frequency noise due to ghost cavitation for two different air gun arrays. Both of the arrays have three subarrays but the array distance for the one with 2730 in3 air volume is 6 meters and for the slightly bigger array (3250 in3 in air volume) the subarrays are separated by 8 meters. Simulation results indicate that the second array, despite larger subarray distance, generates stronger ghost cavitation signal.

  16. A handheld low temperature atmospheric pressure air plasma gun for nanomaterial synthesis in liquid phase

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yu, Shuang; Wang, Kaile; Zuo, Shasha

    A handheld low temperature atmospheric pressure air plasma gun based on a dielectric barrier structure with hollow electrodes was proposed. The portable plasma gun with an embedded mini air pump was driven by a 12 V direct voltage battery. The air plasma jet generated from the gun could be touched without a common shock hazard. Besides working in air, the plasma gun can also work in water. The diagnostic result of optical emission spectroscopy showed the difference in reactive species of air plasma jet between in air and in water. The plasma gun was excited in 20 ml chloroauric acid aqueous solutionmore » with a concentration of 1.214 mM. A significant amount of gold nanoparticles were synthesized after 2 min continuous discharge. The plasma gun with these unique features is applicable in plasma medicine, etching, and s-nthesis of nanomaterials.« less

  17. Influence of pellet seating on the external ballistic parameters of spring-piston air guns.

    PubMed

    Werner, Ronald; Schultz, Benno; Frank, Matthias

    2016-09-01

    In firearm examiners' and forensic specialists' casework as well as in air gun proof testing, reliable measurement of the weapon's muzzle velocity is indispensable. While there are standardized and generally accepted procedures for testing the performance of air guns, the method of seating the diabolo pellets deeper into the breech of break barrel spring-piston air guns has not found its way into standardized test procedures. The influence of pellet seating on the external ballistic parameters was investigated using ten different break barrel spring-piston air guns. Test shots were performed with the diabolo pellets seated 2 mm deeper into the breech using a pellet seater. The results were then compared to reference shots with conventionally loaded diabolo pellets. Projectile velocity was measured with a high-precision redundant ballistic speed measurement system. In eight out of ten weapons, the muzzle energy increased significantly when the pellet seater was used. The average increase in kinetic energy was 31 % (range 9-96 %). To conclude, seating the pellet even slightly deeper into the breech of spring-piston air guns might significantly alter the muzzle energy. Therefore, it is strongly recommended that this effect is taken into account when accurate and reliable measurements of air gun muzzle velocity are necessary.

  18. A NEW THERMIONIC RF ELECTRON GUN FOR SYNCHROTRON LIGHT SOURCES

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kutsaev, Sergey; Agustsson, R.; Hartzell, J

    A thermionic RF gun is a compact and efficient source of electrons used in many practical applications. RadiaBeam Systems and the Advanced Photon Source at Argonne National Laboratory collaborate in developing of a reliable and robust thermionic RF gun for synchrotron light sources which would offer substantial improvements over existing thermionic RF guns and allow stable operation with up to 1A of beam peak current at a 100 Hz pulse repetition rate and a 1.5 μs RF pulse length. In this paper, we discuss the electromagnetic and engineering design of the cavity and report the progress towards high power testsmore » of the cathode assembly of the new gun.« less

  19. Self-contained hot-hollow cathode gun source assembly

    DOEpatents

    Zeren, Joseph D.

    1986-01-01

    A self-contained hot-hollow cathode gun source assembly for use in a vacuum chamber includes a crucible block having a hot-hollow cathode gun mounted underneath and providing a hole for the magnetic deflection of the ion/electron beam into a crucible on top the block.

  20. Self-contained hot-hollow cathode gun source assembly

    DOEpatents

    Zeren, J.D.

    1984-08-01

    A self-contained hot-hollow cathode gun source assembly for use in a vacuum chamber includes a crucible block having a hot-hollow cathode gun mounted underneath and providing a hole for the magnetic deflection of the ion/electron beam into a crucible on top the block.

  1. Air gun injury with deadly aftermath--case report.

    PubMed

    Stankov, Aleksandar; Jakovski, Zlatko; Pavlovski, Goran; Muric, Nedzat; Dwork, Andrew J; Cakar, Zdravko

    2013-01-01

    In Republic of Macedonia the use of air guns is quite widespread. They are used mainly for target practice. They are regulated by the Law of Arms, where they are defined as pneumatic weapons. There is no legal limit on type or quantity of ammunition that one may possess. Our Institute performs at least 90% of the forensic autopsies in Macedonia. In this report we describe the only fatality by pneumatic weapon to come to our attention over the past 10 years. A 6-year-old girl was accidentally wounded by her brother when he and his father were trying a new air gun, a 4.5mm single shot, break barrel, spring piston air rifle manufactured in China under the brand "Westlake". She died within minutes. Autopsy showed cardiac tamponade due to penetration of the aorta. A 0.5g metal projectile, 4.5mm in diameter, with a pointed, conical shape, was recovered from the pericardial sac. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  2. Penetrated sigmoid colon by air gun pellet could be life threatening: A case report

    PubMed Central

    Krasniqi, Avdyl S.; Hamza, Astrit R.; Zejnullahu, Valon A.; Sada, Fatos E.; Bicaj, Besnik X.

    2014-01-01

    INTRODUCTION Air and paintball guns have been in existence for over 400 year. Although serious injury or death can result from the use of such guns, previous literature has not mentioned the issue of the penetration of the sigmoid colon by an air gun pellet. PRESENTATION OF CASE We report a rare case of a 44-year-old Caucasian woman referred to abdominal surgery after an accidental small wound had occurred in the lower left abdominal quadrant that was caused by an air gun pellet. The blood and biochemical analyses were normal but the CT scan revealed the presence of a foreign body – an air gun pellet in the left iliac region of the abdomen. Clinically, during the initial 24 h significant changes were not noticed. After 42 h, however, pain and local tenderness in the lower left abdominal quadrant was expressed. A laparotomy revealed a retained pellet in the wall of the sigmoid colon and a small leak with colonic content with consecutive local peritonitis also occurred. The foreign body was removed and the opening edges in the colon were excised and closed with the primary suture. DISCUSSION The hollow organs of the digestive tract, albeit very rarely penetrated by an air gun pellet, do not typically show all signs of an acute abdomen in the early posttraumatic phase. Such injuries can lead to a pronounced infection, which may cause septic shock if not appropriately treated. CONCLUSION For correct diagnosis, a careful approach and several daily clinical observations are required. PMID:25437671

  3. Quantitative measures of air-gun pulses recorded on sperm whales (Physeter macrocephalus) using acoustic tags during controlled exposure experiments.

    PubMed

    Madsen, P T; Johnson, M; Miller, P J O; Aguilar Soto, N; Lynch, J; Tyack, P

    2006-10-01

    The widespread use of powerful, low-frequency air-gun pulses for seismic seabed exploration has raised concern about their potential negative effects on marine wildlife. Here, we quantify the sound exposure levels recorded on acoustic tags attached to eight sperm whales at ranges between 1.4 and 12.6 km from controlled air-gun array sources operated in the Gulf of Mexico. Due to multipath propagation, the animals were exposed to multiple sound pulses during each firing of the array with received levels of analyzed pulses falling between 131-167 dB re. 1 microPa (pp) [111-147 dB re. 1 microPa (rms) and 100-135 dB re. 1 microPa2 s] after compensation for hearing sensitivity using the M-weighting. Received levels varied widely with range and depth of the exposed animal precluding reliable estimation of exposure zones based on simple geometric spreading laws. When whales were close to the surface, the first arrivals of air-gun pulses contained most energy between 0.3 and 3 kHz, a frequency range well beyond the normal frequencies of interest in seismic exploration. Therefore air-gun arrays can generate significant sound energy at frequencies many octaves higher than the frequencies of interest for seismic exploration, which increases concern of the potential impact on odontocetes with poor low frequency hearing.

  4. Energy-dependent expansion of .177 caliber hollow-point air gun projectiles.

    PubMed

    Werner, Ronald; Schultz, Benno; Bockholdt, Britta; Ekkernkamp, Axel; Frank, Matthias

    2017-05-01

    Amongst hundreds of different projectiles for air guns available on the market, hollow-point air gun pellets are of special interest. These pellets are characterized by a tip or a hollowed-out shape in their tip which, when fired, makes the projectiles expand to an increased diameter upon entering the target medium. This results in an increase in release of energy which, in turn, has the potential to cause more serious injuries than non-hollow-point projectiles. To the best of the authors' knowledge, reliable data on the terminal ballistic features of hollow-point air gun projectiles compared to standard diabolo pellets have not yet been published in the forensic literature. The terminal ballistic performance (energy-dependent expansion and penetration) of four different types of .177 caliber hollow-point pellets discharged at kinetic energy levels from approximately 3 J up to 30 J into water, ordnance gelatin, and ordnance gelatin covered with natural chamois as a skin simulant was the subject of this investigation. Energy-dependent expansion of the tested hollow-point pellets was observed after being shot into all investigated target media. While some hollow-point pellets require a minimum kinetic energy of approximately 10 J for sufficient expansion, there are also hollow-point pellets which expand at kinetic energy levels of less than 5 J. The ratio of expansion (RE, calculated by the cross-sectional area (A) after impact divided by the cross-sectional area (A 0 ) of the undeformed pellet) of hollow-point air gun pellets reached values up of to 2.2. The extent of expansion relates to the kinetic energy of the projectile with a peak for pellet expansion at the 15 to 20 J range. To conclude, this work demonstrates that the hollow-point principle, i.e., the design-related enlargement of the projectiles' frontal area upon impact into a medium, does work in air guns as claimed by the manufacturers.

  5. Pediatric air gun shot injury.

    PubMed

    Khan, Ubaid U; Kamal, Naglaa M; Mirza, Shazia J; Sherief, Laila M

    2014-12-01

    Air guns (AGs) use air or another compressed gas to propel a projectile. Different injuries may occur in children due to their body structure, which is less-resistant with thin soft tissue coverage that can be easily penetrated by an AG shot. We present 3 cases of pediatric AG shot injury. The first-case had right lumber deep tissue penetration of AG pallet without internal damage, the second-case had a complex course of pellet into the perineum, and the third-case was shot in the left shoulder. All cases were accidentally shot. The shooters were all children, and relatives of the victims. All patients were generally stable on arrival. Two cases were operated, and one received conservative management. On follow up, no complications were noted.  At first sight, AGs and air rifles may appear relatively harmless, but they are potentially lethal and children should not be allowed to play with them. 

  6. Nozzle Extension for Safety Air Gun

    NASA Technical Reports Server (NTRS)

    Zumbrun, H. N.; Croom, Delwin R., Jr.

    1986-01-01

    New nozzle-extension design overcomes problems and incorporates original commercial nozzle, retaining intrinsic safety features. Components include extension tube, length of which made to suit application; adaptor fitting, and nozzle adaptor repinned to maintain original safety features. Design moves conical airstream to end of extension to blow machine chips away from operator. Nozzle-extension modification allows safe and efficient operation of machine tools while maintaining integrity of orginial safety-air-gun design.

  7. Sources of guns to dangerous people: what we learn by asking them.

    PubMed

    Cook, Philip J; Parker, Susan T; Pollack, Harold A

    2015-10-01

    Gun violence exacts a lethal toll on public health. This paper focuses on reducing access to firearms by dangerous offenders, contributing original empirical data on the gun transactions that arm offenders in Chicago. Conducted in the fall of 2013, analysis of an open-ended survey of 99 inmates of Cook County Jail focuses on a subset of violence-prone individuals with the goal of improving law enforcement actions. Among our principal findings: *Our respondents (adult offenders living in Chicago or nearby) obtain most of their guns from their social network of personal connections. Rarely is the proximate source either direct purchase from a gun store, or theft. *Only about 60% of guns in the possession of respondents were obtained by purchase or trade. Other common arrangements include sharing guns and holding guns for others. *About one in seven respondents report selling guns, but in only a few cases as a regular source of income. *Gangs continue to play some role in Chicago in organizing gun buys and in distributing guns to members as needed. *The Chicago Police Department has a considerable effect on the workings of the underground gun market through deterrence. Transactions with strangers and less-trusted associates are limited by concerns over arrest risk (if the buyer should happen to be an undercover officer or a snitch), and about being caught with a "dirty" gun (one that has been fired in a crime). Copyright © 2015 Elsevier Inc. All rights reserved.

  8. Use of a seismic air gun to reduce survival of nonnative lake trout embryos: A tool for conservation?

    USGS Publications Warehouse

    Cox, B.S.; Dux, A.M.; Quist, M.C.; Guy, C.S.

    2012-01-01

    The detrimental impacts of nonnative lake trout Salvelinus namaycush in the western USA have prompted natural resource management agencies in several states to implement lake trout suppression programs. Currently, these programs rely on mechanical removal methods (i.e., gill nets, trap nets, and angling) to capture subadult and adult lake trout. We conducted a study to explore the potential for using high-intensity sound from a relatively small (655.5 cm3 [40 in3]) seismic air gun to reduce survival of lake trout embryos. Lake trout embryos at multiple stages of development were exposed to a single discharge of the seismic air gun at two depths (5 and 15 m) and at two distances from the air gun (0.1 and 2.7 m). Control groups for each developmental stage, distance, and depth were treated identically except that the air gun was not discharged. Mortality in lake trout embryos treated at 0.1 m from the air gun was 100% at 74 daily temperature units in degrees Celsius (TU°C) at both depths. Median mortality in lake trout embryos treated at 0.1 m from the air gun at 207 TU°C (93%) and 267 °C (78%) appeared to be higher than that of controls (49% and 48%, respectively) at 15-m depth. Among the four lake trout developmental stages, exposure to the air gun at 0.1 m resulted in acute mortality up to 60% greater than that of controls. Mortality at a distance of 2.7 m did not appear to differ from that of controls at any developmental stage or at either depth. Our results indicate that seismic air guns have potential as an alternative tool for controlling nonnative lake trout, but further investigation is warranted.

  9. MODE IDENTIFICATION OF AN ARCH DAM BY A DYNAMIC AIR-GUN TEST.

    USGS Publications Warehouse

    Liu, Hsi-Ping; Fedock, Joseph J.; Fletcher, Jon B.

    1986-01-01

    Thirteen natural frequencies of a concrete arch dam (Monticello Dam near Sacramento, California) have been identified by using a dynamic testing method which employs an air gun firing in the reservoir as the excitation source. These vibrations modes are determined from the peak responses in the Fourier amplitude spectra of the free-vibration data recorded at three crest locations using three-component geophones. Comparisons of the first five natural frequencies with results obtained by forced vibration tests using rotating mass shakers show good agreement. The next eight higher-frequency modes, not previously identified, are determined from data of the present tests.

  10. A piloted simulation investigation of yaw dynamics requirements for turreted gun use in low-level helicopter air combat

    NASA Technical Reports Server (NTRS)

    Decker, William A.; Morris, Patrick M.; Williams, Jeffrey N.

    1988-01-01

    A piloted, fixed-base simulation study was conducted to investigate the handling qualities requirements for helicopter air-to-air combat using turreted guns in the near-terrain environment. The study used a version of the helicopter air combat system developed at NASA Ames Research Center for one-on-one air combat. The study focused on the potential trade-off between gun angular movement capability and required yaw axis response. Experimental variables included yaw axis response frequency and damping and the size of the gun-movement envelope. A helmet position and sighting system was used for pilot control of gun aim. Approximately 340 simulated air combat engagements were evaluated by pilots from the Army and industry. Results from the experiment indicate that a highly-damped, high frequency yaw response was desired for Level I handling qualities. Pilot preference for those characteristics became more pronounced as gun turret movement was restricted; however, a stable, slow-reacting platform could be used with a large turret envelope. Most pilots preferred to engage with the opponent near the own-ship centerline. Turret elevation restriction affected the engagement more than azimuth restrictions.

  11. Air pollution: a smoking gun for cancer.

    PubMed

    Zhang, Wei; Qian, Chao-Nan; Zeng, Yi-Xin

    2014-04-01

    Once considered a taboo topic or stigma, cancer is the number one public health enemy in the world. Once a product of an almost untouchable industry, tobacco is indisputably recognized as a major cause of cancer and a target for anticancer efforts. With the emergence of new economic powers in the world, especially in highly populated countries such as China, air pollution has rapidly emerged as a smoking gun for cancer and has become a hot topic for public health debate because of the complex political, economic, scientific, and technologic issues surrounding the air pollution problem. This editorial and the referred articles published in this special issue of the Chinese Journal of Cancer discuss these fundamental questions. Does air pollution cause a wide spectrum of cancers? Should air pollution be considered a necessary evil accompanying economic transformation in developing countries? Is an explosion of cancer incidence coming to China and how soon will it arrive? What must be done to prevent this possible human catastrophe? Finally, the approaches for air pollution control are also discussed.

  12. Air pollution: a smoking gun for cancer

    PubMed Central

    Zhang, Wei; Qian, Chao-Nan; Zeng, Yi-Xin

    2014-01-01

    Once considered a taboo topic or stigma, cancer is the number one public health enemy in the world. Once a product of an almost untouchable industry, tobacco is indisputably recognized as a major cause of cancer and a target for anticancer efforts. With the emergence of new economic powers in the world, especially in highly populated countries such as China, air pollution has rapidly emerged as a smoking gun for cancer and has become a hot topic for public health debate because of the complex political, economic, scientific, and technologic issues surrounding the air pollution problem. This editorial and the referred articles published in this special issue of the Chinese Journal of Cancer discuss these fundamental questions. Does air pollution cause a wide spectrum of cancers? Should air pollution be considered a necessary evil accompanying economic transformation in developing countries? Is an explosion of cancer incidence coming to China and how soon will it arrive? What must be done to prevent this possible human catastrophe? Finally, the approaches for air pollution control are also discussed. PMID:24636233

  13. Country made scare gun vs. air gun--a comparative study of terminal ballistics using gelatine blocks.

    PubMed

    Hallikeri, Vinay R; Gouda, Hareesh S; Kadagoudar, Shivanand A

    2012-01-10

    Country made scare gun also called as bandook in the vernacular language designed with an intention of scaring away the menacing animals is not only unique and effective but also potentially lethal and has found wide spread usage in the rural parts of India. Here an attempt has been made to study the characteristic features such as physical dimensions, mechanism of action of this weapon and to compare its penetrating ability with that of air gun, whose potential lethality is a well-documented fact, using the ballistic gelatine blocks at various ranges. It is hoped that keeping the existence of such firearms in mind by the forensic experts might help to solve the unexplained and bizarre firearm injuries encountered in day to day practice. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  14. Carbon Nanotube Electron Gun

    NASA Technical Reports Server (NTRS)

    Ribaya, Bryan P. (Inventor); Nguyen, Cattien V. (Inventor)

    2013-01-01

    An electron gun, an electron source for an electron gun, an extractor for an electron gun, and a respective method for producing the electron gun, the electron source and the extractor are disclosed. Embodiments provide an electron source utilizing a carbon nanotube (CNT) bonded to a substrate for increased stability, reliability, and durability. An extractor with an aperture in a conductive material is used to extract electrons from the electron source, where the aperture may substantially align with the CNT of the electron source when the extractor and electron source are mated to form the electron gun. The electron source and extractor may have alignment features for aligning the electron source and the extractor, thereby bringing the aperture and CNT into substantial alignment when assembled. The alignment features may provide and maintain this alignment during operation to improve the field emission characteristics and overall system stability of the electron gun.

  15. Carbon nanotube electron gun

    NASA Technical Reports Server (NTRS)

    Nguyen, Cattien V. (Inventor); Ribaya, Bryan P. (Inventor)

    2010-01-01

    An electron gun, an electron source for an electron gun, an extractor for an electron gun, and a respective method for producing the electron gun, the electron source and the extractor are disclosed. Embodiments provide an electron source utilizing a carbon nanotube (CNT) bonded to a substrate for increased stability, reliability, and durability. An extractor with an aperture in a conductive material is used to extract electrons from the electron source, where the aperture may substantially align with the CNT of the electron source when the extractor and electron source are mated to form the electron gun. The electron source and extractor may have alignment features for aligning the electron source and the extractor, thereby bringing the aperture and CNT into substantial alignment when assembled. The alignment features may provide and maintain this alignment during operation to improve the field emission characteristics and overall system stability of the electron gun.

  16. Image-guided percutaneous removal of ballistic foreign bodies secondary to air gun injuries.

    PubMed

    Rothermund, Jacob L; Rabe, Andrew J; Zumberge, Nicholas A; Murakami, James W; Warren, Patrick S; Hogan, Mark J

    2018-01-01

    Ballistic injuries with retained foreign bodies from air guns is a relatively common problem, particularly in children and adolescents. If not removed in a timely fashion, the foreign bodies can result in complications, including pain and infection. Diagnostic methods to identify the presence of the foreign body run the entire gamut of radiology, particularly radiography, ultrasound (US) and computed tomography (CT). Removal of the foreign bodies can be performed by primary care, emergency, surgical, and radiologic clinicians, with or without imaging guidance. To evaluate the modalities of radiologic detection and the experience of image-guided ballistic foreign body removal related to air gun injuries within the interventional radiology department of a large pediatric hospital. A database of more than 1,000 foreign bodies that were removed with imaging guidance by the interventional radiologists at our institution was searched for ballistic foreign bodies from air guns. The location, dimensions, diagnostic modality, duration, complications and imaging modality used for removal were recorded. In addition, the use of sedation and anesthesia required for the procedures was also recorded. Sixty-one patients with ballistic foreign bodies were identified. All foreign bodies were metallic BBs or pellets. The age of the patients ranged from 5 to 20 years. The initial diagnostic modality to detect the foreign bodies was primarily radiography. The primary modality to assist in removal was US, closely followed by fluoroscopy. For the procedure, 32.7% of the patients required some level of sedation. Only two patients had an active infection at the time of the removal. The foreign bodies were primarily in the soft tissues; however, successful removal was also performed from intraosseous, intraglandular and intratendinous locations. All cases resulted in successful removal without complications. Image-guided removal of ballistic foreign bodies secondary to air guns is a very

  17. Development of 50kV air-core transformer for electron gun static power source of 3MeV DC accelerator

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dewangan, S.; Bakhtsingh, R.I.; Rajan, R.N.

    A 3 MeV, 10 mA DC Electron Beam Accelerator based on the capacitively coupled parallel-fed voltage multiplier in 6 kg/cm{sup 2} SF{sub 6} gas environment is under commissioning at Electron Beam Centre, Kharghar, Navi Mumbai. Electron Gun is situated at -3 MV terminal which requires a constant power for its anode and filament. Gun power source has been derived by suitably coupling the ac components present in the HV Multiplier column. An aircore step down transformer rated for 50kV/600V/120kHz floating at 3 MV to extract the required power for electron gun from high voltage column has been developed. The transformermore » has been operated for 7 kW, 1 MeV of electron beam in 6 kg/cm{sup 2} nitrogen gas environment. The paper describes briefly about the design aspects and test results. (author)« less

  18. Seismic data collection from water gun and industrial background sources in the Chicago Sanitary and Ship Canal area, Illinois, 2011

    USGS Publications Warehouse

    Morrow, William S.; Carpenter, Phillip J.; Adams, Ryan F.

    2015-01-01

    The water gun is a tool adapted from deep marine geophysical surveys that is being evaluated for use as an acoustic fish deterrent to control the movement of invasive marine species. The water gun creates a seismic signal by using a compressed air discharge to move a piston rapidly within the water, resulting in an implosion. This energy pulse may be able to modify fish behavior or destroy marine life, such as the Asian carp, at some distance. The effects of this energy pulse on structures in the Chicago Sanitary and Ship Canal (CSSC), such as canal walls, shore lines, and lock structures, are not known. The potential effects of the use of a water gun on structures was identified as a concern in the CSSC and was assessed relative to existing background sources during this study. During September 2011, two water guns with piston sizes of 80 and 343 cubic inches, respectively, were tested in the CSSC at varying pressures and distances from a canal wall consisting of dolomite and dolomite setblock. Seismic data were collected during these water gun firings using geophones on land, in boreholes, and at the canal wall interface. Data were collected at varying depths in the canal water using hydrophones. Seismic data were also collected during the occurrences of barge traffic, railroad traffic located near the electric fish barrier in Lemont, and coal-loading operations at a coal power plant near the electric fish barrier. In general, energy produced by barge and railroad sources was less than energy created by the water gun. Energy levels produced by coal-loading operations at least 200 feet from geophones were approximately four times lower than energy levels measured during water gun operations.

  19. Air Gun Launch Simulation Modeling and Finite Element Model Sensitivity Analysis

    DTIC Science & Technology

    2006-01-01

    Mr. Edward Szymanski, and Mr. William McIntosh of ARL in delivering the air gun test are greatly appreciated. Dr. Dave Hampton of the U.S. Military...ARMY RSCH LABORATORY ATTN AMSRD ARL WM BD P CONROY B FORCH M LEADORE R LIEB B RICE R PESCE RODRIGUEZ A ZIELINSKI BLDG 4600

  20. The Influence of Shaping Air Pressure of Pneumatic Spray Gun

    NASA Astrophysics Data System (ADS)

    Chen, Wenzhuo; Chen, Yan; Pan, Haiwei; Zhang, Weiming; Li, Bo

    2018-02-01

    The shaping air pressure is a very important parameter in the application of pneumatic spray gun, and studying its influence on spray flow field and film thickness distribution has practical values. In this paper, Euler-Lagrangian method is adopted to describe the two-phase spray flow of pneumatic painting process, and the air flow fields, spray patterns and dynamic film thickness distributions were obtained with the help of the computational fluid dynamics code—ANSYS Fluent. Results show that with the increase of the shaping air pressure, the air phase flow field spreads in the plane perpendicular to the shaping air hole plane, the spray pattern becomes narrower and flatter, and the width of the dynamic film increases with the reduced maximum value of the film thickness. But the film thickness distribution seems to change little with the shaping air pressure decreasing from 0.6bar to 0.9bar.

  1. RF Conditioning of the Photo-Cathode RF Gun at the Advanced Photon Source - NWA RF Measurements

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Smith, T. L.; DiMonte, N.; Nassiri, A.

    A new S-band Photo-cathode (PC) gun was recently installed and RF conditioned at the Advanced Photon Source (APS) Injector Test-stand (ITS) at Argonne National Lab (ANL). The APS PC gun is a LCLS type gun fabricated at SLAC [1]. The PC gun was delivered to the APS in October 2013 and installed in the APS ITS in December 2013. At ANL, we developed a new method of fast detection and mitigation of the guns internal arcs during the RF conditioning process to protect the gun from arc damage and to RF condition more efficiently. Here, we report the results ofmore » RF measurements for the PC gun and an Auto-Restart method for high power RF conditioning.« less

  2. [Management of penile trauma from compressed air gun in a child].

    PubMed

    Girón-Vallejo, O; Zambudio, G; Ruiz-Pruneda, R; Hernindez, J P; Ruiz-Jiménez, J I

    2011-01-01

    We report on a 6-year old child with a penile injury resulting in the inclusion of a pellet in the cavernous body, by a fortuitous shot. Conservative approach with elective extraction of the bullet and cavernous body repair led to a satisfactory result, in better anatomic conditions. The patient did not have any perioperative complication. Accidents by air weapons are particularly important in children, because these weapons are erroneously considered as toys. Air gun injuries to head, neck and thorax have been often published, but these injuries are rare in the chidren genitourinary area.

  3. Seismic air gun exposure during early-stage embryonic development does not negatively affect spiny lobster Jasus edwardsii larvae (Decapoda:Palinuridae)

    PubMed Central

    Day, Ryan D.; McCauley, Robert D.; Fitzgibbon, Quinn P.; Semmens, Jayson M.

    2016-01-01

    Marine seismic surveys are used to explore for sub-seafloor oil and gas deposits. These surveys are conducted using air guns, which release compressed air to create intense sound impulses, which are repeated around every 8–12 seconds and can travel large distances in the water column. Considering the ubiquitous worldwide distribution of seismic surveys, the potential impact of exposure on marine invertebrates is poorly understood. In this study, egg-bearing female spiny lobsters (Jasus edwardsii) were exposed to signals from three air gun configurations, all of which exceeded sound exposure levels (SEL) of 185 dB re 1 μPa2·s. Lobsters were maintained until their eggs hatched and the larvae were then counted for fecundity, assessed for abnormal morphology using measurements of larval length and width, tested for larval competency using an established activity test and measured for energy content. Overall there were no differences in the quantity or quality of hatched larvae, indicating that the condition and development of spiny lobster embryos were not adversely affected by air gun exposure. These results suggest that embryonic spiny lobster are resilient to air gun signals and highlight the caution necessary in extrapolating results from the laboratory to real world scenarios or across life history stages. PMID:26947006

  4. Mechanical design and fabrication of the VHF-gun, the Berkeley normal-conducting continuous-wave high-brightness electron source

    NASA Astrophysics Data System (ADS)

    Wells, R. P.; Ghiorso, W.; Staples, J.; Huang, T. M.; Sannibale, F.; Kramasz, T. D.

    2016-02-01

    A high repetition rate, MHz-class, high-brightness electron source is a key element in future high-repetition-rate x-ray free electron laser-based light sources. The VHF-gun, a novel low frequency radio-frequency gun, is the Lawrence Berkeley National Laboratory (LBNL) response to that need. The gun design is based on a normal conducting, single cell cavity resonating at 186 MHz in the VHF band and capable of continuous wave operation while still delivering the high accelerating fields at the cathode required for the high brightness performance. The VHF-gun was fabricated and successfully commissioned in the framework of the Advanced Photo-injector EXperiment, an injector built at LBNL to demonstrate the capability of the gun to deliver the required beam quality. The basis for the selection of the VHF-gun technology, novel design features, and fabrication techniques are described.

  5. Mechanical design and fabrication of the VHF-gun, the Berkeley normal-conducting continuous-wave high-brightness electron source.

    PubMed

    Wells, R P; Ghiorso, W; Staples, J; Huang, T M; Sannibale, F; Kramasz, T D

    2016-02-01

    A high repetition rate, MHz-class, high-brightness electron source is a key element in future high-repetition-rate x-ray free electron laser-based light sources. The VHF-gun, a novel low frequency radio-frequency gun, is the Lawrence Berkeley National Laboratory (LBNL) response to that need. The gun design is based on a normal conducting, single cell cavity resonating at 186 MHz in the VHF band and capable of continuous wave operation while still delivering the high accelerating fields at the cathode required for the high brightness performance. The VHF-gun was fabricated and successfully commissioned in the framework of the Advanced Photo-injector EXperiment, an injector built at LBNL to demonstrate the capability of the gun to deliver the required beam quality. The basis for the selection of the VHF-gun technology, novel design features, and fabrication techniques are described.

  6. Whose guns are stolen? The epidemiology of Gun theft victims.

    PubMed

    Hemenway, David; Azrael, Deborah; Miller, Matthew

    2017-12-01

    Gun theft is an important source of guns used by criminals. Yet no empirical work has focused on the characteristics of gun owners that distinguish those who have had their guns stolen from those who have not. In this study, we examine the demographics and behavioral characteristics of gun owners who report having had a gun stolen. Data come from a nationally representative probability-based online survey conducted in April 2015, with a linked follow-up survey in November 2015 that asked gun owners about any theft of their guns in the past 5 years. Of 1,604 gun-owning respondents, 2.4% (95% CI 1.6,3.6) reported that one or more guns had been stolen, with a mean number of guns stolen per theft of 1.5 (95% CI 1.0,2.0]. Risk factors for having a gun stolen were owning 6 or more guns, owning guns for protection, carrying a gun in the past month, storing guns unsafely, and living in the South region of the United States. The South accounts for 37% of US households, 43% of gun owners, and two-thirds of all gun thefts. We estimate that there are approximately 250,000 gun theft incidents per year, with about 380,000 guns stolen. We find that certain types of gun owners-who own many guns, who carry guns, and who do not store guns safely-are at higher risk to have their guns stolen. Tracing data show that states in the South are exporters of crime guns used in other states. Our survey results find that the majority of guns stolen in the US come from the South.

  7. Extraction of Pn seismic signals from air-gun shots recorded by the Cascadia Amphibious seismic experiment

    NASA Astrophysics Data System (ADS)

    Rathnayaka, S.; Gao, H.

    2017-12-01

    The goal of this study is to extract Pn (head wave) seismic waveforms recorded by both offshore and onshore (broadband and short period) seismic stations and evaluate the data quality. Two offshore active-source seismic experiments, MGL 1211 and MGL 1212, were conducted from 13th June to 24th July 2012, during the first year deployment of the Cascadia Initiative Amphibious Array. In total, we choose 110 ocean bottom seismometers and 209 inland stations that are located along the entire Cascadia subduction zone. We first remove the instrument response, and then explore the potential frequency ranges and the diurnal effect. We make the common receiver gathering for each seismic station and filter the seismic waveforms at multiple frequency bands, ranging from 3-5 Hz, 5-10 Hz, 10-20 Hz, to 20-40 Hz, respectively. To quantitatively evaluate the data quality, we calculate the signal-to-noise ratio (SNR) of the waveforms for usable stations that record clear Pn arrivals at multiple frequency bands. Our results show that most offshore stations located at deep water (>1.5 km) record clear air-gun shot signals at frequencies higher than 3 Hz and up to 550 km away from the source. For most stations located on the shallow continental shelf, the seismic recordings appear much noisier at all the frequencies compared to stations at deep water. Three general trends are observed for the SNR distribution; First, the SNR ratio increases from lower to higher frequency bands; Second, the ratio decreases with the increasing source-to-receiver distance; And third, the ratio increases from shallow to deep water. We also observe a rough negative relationship of the signal-to-noise ratio with the thickness of the marine sediment. Only 5 inland stations record clear air-gun shot arrivals up to 200 km away from the source. More detailed data quality analysis with more results will also be present.

  8. Development of ion source with a washer gun for pulsed neutral beam injection.

    PubMed

    Asai, T; Yamaguchi, N; Kajiya, H; Takahashi, T; Imanaka, H; Takase, Y; Ono, Y; Sato, K N

    2008-06-01

    A new type of economical neutral beam source has been developed by using a single washer gun, pulsed operation, and a simple electrode system. We replaced the conventional hot filaments for arc-discharge-type plasma formation with a single stainless-steel washer gun, eliminating the entire dc power supply for the filaments and the cooling system for the electrodes. Our initial experiments revealed successful beam extraction up to 10 kV and 8.6 A, based on spatial profile measurements of density and temperature in the plasma source. The system also shows the potential to control the beam profile by controlling the plasma parameters in the ion accumulation chamber.

  9. Experimental effect of shots caused by projectiles fired from air guns with kinetic energy below 17 J.

    PubMed

    Smędra-Kaźmirska, Anna; Barzdo, Maciej; Kędzierski, Maciej; Antoszczyk, Łukasz; Szram, Stefan; Berent, Jarosław

    2013-09-01

    Pursuant to the Polish Weapons and Ammunitions Law (Legal Gazette No 53/1999 item 549 with subsequent amendments), air guns with kinetic energy of the fired projectiles below 17 J are not regarded as weapons. The aim of the study was to assess the potential effect of shots caused by projectiles of various mass and structure fired from air guns with kinetic energy below 17 J on human soft tissues. As a model of soft tissue, we used 20% gelatin blocks. After shooting, we measured the depth of gelatin block penetration by pellets fired from various distances and compared these results with autopsy findings. The results demonstrated that examined pneumatic guns may cause serious injuries, including damage to the pleura, pericardium, liver, spleen, kidneys, femoral artery, and thoracic and abdominal aorta. Experiment shown that gelatin blocks do not reflect fully the properties of the human body. © 2013 American Academy of Forensic Sciences.

  10. Fabrication of compact electron gun for 6 MeV X-ray source

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ghodke, S.R.; Barnwal, Rajesh; Kumar, Mahendra, E-mail: ghodke_barc@yahoo.co.in

    The 6 MeV X-Ray source for container cargo scanning application has been designed and developed by the Accelerator and Pulse Power Division, BARC, Mumbai. This compact linac has been designed as a mobile system, to be mounted on a moving container. In linac-based cargo-scanning system, to work electron gun on a movable container, it has to be robust. Electron gun is to work at 10{sup -7} mbar vacuum and 2000 degree Celsius temperature. An effort is made to engineer the gun assembly to make it more robust and aligned. The linac acts as the source of X-rays, which fall onmore » the cargo and are then detected by the detector system. Many components are indigenously developed like grid, insulating ring, Tungsten filament and filament guide, which are made from alumina ceramic and Tantalum which is to work at 1500 degree Celsius. Filament connector is made from Invar to reduce heat loss and to make rigid connection. It was CNC machined and wire cut by EDM. Invar and Copper electrode feed through is shrink fitted with the help of liquid Nitrogen. Shrink fit tolerances of 15 micrometer are achieved by jig boring machining processes. Tantalum cup for LaB6 cathode and heat shield are made from die and punch mechanism. For alignment of electron emitter with beam axis this Tantalum cup is a crucial component. Electron gun is assembled and aligned its components with the help of precision jigs. The whole assembly was Helium leak tested by MSLD up to 4 x 10{sup -10} mbar.l/s vacuum, no leak was found. This paper will describe the machining, Tantalum cup forming, ceramic components development, heat shields, ceramic feed through etc of electron gun. (author)« less

  11. Note: Simulation and test of a strip source electron gun.

    PubMed

    Iqbal, Munawar; Islam, G U; Misbah, I; Iqbal, O; Zhou, Z

    2014-06-01

    We present simulation and test of an indirectly heated strip source electron beam gun assembly using Stanford Linear Accelerator Center (SLAC) electron beam trajectory program. The beam is now sharply focused with 3.04 mm diameter in the post anode region at 15.9 mm. The measured emission current and emission density were 1.12 A and 1.15 A/cm(2), respectively, that corresponds to power density of 11.5 kW/cm(2), at 10 kV acceleration potential. The simulated results were compared with then and now experiments and found in agreement. The gun is without any biasing, electrostatic and magnetic fields; hence simple and inexpensive. Moreover, it is now more powerful and is useful for accelerators technology due to high emission and low emittance parameters.

  12. Gas gun dynamics

    NASA Astrophysics Data System (ADS)

    Denny, Mark

    2013-09-01

    The mechanics and thermodynamics of one- and two-stage gas guns are developed. Very high projectile muzzle speed can be obtained by the two-stage version. The physics of simple gas guns, such as air rifles, is accessible to undergraduates and the same level of presentation is used here to understand more complex designs. Numerical solutions to the equations of motion are shown, along with insightful analytic approximations.

  13. The Internal Ballistics of an Air Gun

    NASA Astrophysics Data System (ADS)

    Denny, Mark

    2011-02-01

    The internal ballistics of a firearm or artillery piece considers the pellet, bullet, or shell motion while it is still inside the barrel. In general, deriving the muzzle speed of a gunpowder firearm from first principles is difficult because powder combustion is fast and it very rapidly raises the temperature of gas (generated by gunpowder deflagration, or burning), which greatly complicates the analysis. A simple case is provided by air guns, for which we can make reasonable approximations that permit a derivation of muzzle speed. It is perhaps surprising that muzzle speed depends upon barrel length (artillerymen debated this dependence for centuries, until it was established experimentally and, later, theoretically ). Here we see that a simple physical analysis, accessible to high school or freshmen undergraduate physics students, not only derives realistic muzzle speed but also shows how it depends upon barrel length.

  14. Note: Simulation and test of a strip source electron gun

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Iqbal, Munawar, E-mail: muniqbal.chep@pu.edu.pk; Institute of High Energy Physics, Chinese Acedemy of Sciences, Beijing 100049; Islam, G. U.

    We present simulation and test of an indirectly heated strip source electron beam gun assembly using Stanford Linear Accelerator Center (SLAC) electron beam trajectory program. The beam is now sharply focused with 3.04 mm diameter in the post anode region at 15.9 mm. The measured emission current and emission density were 1.12 A and 1.15 A/cm{sup 2}, respectively, that corresponds to power density of 11.5 kW/cm{sup 2}, at 10 kV acceleration potential. The simulated results were compared with then and now experiments and found in agreement. The gun is without any biasing, electrostatic and magnetic fields; hence simple and inexpensive.more » Moreover, it is now more powerful and is useful for accelerators technology due to high emission and low emittance parameters.« less

  15. X-Band RF Gun Development

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vlieks, Arnold; Dolgashev, Valery; Tantawi, Sami

    In support of the MEGa-ray program at LLNL and the High Gradient research program at SLAC, a new X-band multi-cell RF gun is being developed. This gun, similar to earlier guns developed at SLAC for Compton X-ray source program, will be a standing wave structure made of 5.5 cells operating in the pi mode with copper cathode. This gun was designed following criteria used to build SLAC X-band high gradient accelerating structures. It is anticipated that this gun will operate with surface electric fields on the cathode of 200 MeV/m with low breakdown rate. RF will be coupled into themore » structure through a final cell with symmetric duel feeds and with a shape optimized to minimize quadrupole field components. In addition, geometry changes to the original gun, operated with Compton X-ray source, will include a wider RF mode separation, reduced surface electric and magnetic fields.« less

  16. Gun shows across a multistate American gun market: observational evidence of the effects of regulatory policies.

    PubMed

    Wintemute, Garen J

    2007-06-01

    To describe gun shows and assess the impact of increased regulation on characteristics linked to their importance as sources of guns used in crime. Cross-sectional, observational. Data were collected at a structured sample of 28 gun shows in California, which regulates these events and prohibits undocumented private party gun sales; and in Arizona, Nevada, Texas and Florida-all leading sources of California's crime guns--where these restrictions do not exist. Size of shows, measured by numbers of gun vendors and people in attendance; number and nature of guns for sale by gun vendors; measures of private party gun sales and illegal surrogate ("straw") gun purchases. Shows in comparison states were larger, but the number of attendees per gun vendor was higher in California. None of these differences was statistically significant. Armed attendees were more common in other states (median 5.7%, interquartile range (IQR) 3.9-10.0%) than in California (median 1.1%, IQR 0.5-2.2%), p = 0.0007. Thirty percent of gun vendors both in California and elsewhere were identifiable as licensed firearm retailers. There were few differences in the types or numbers of guns offered for sale; vendors elsewhere were more likely to sell assault weapons (34.9% and 13.3%, respectively; p = 0.001). Straw purchases were more common in the comparison states (rate ratio 6.6 (95% CI 0.9 to 49.1), p = 0.06). California's regulatory policies were associated with a decreased incidence of anonymous, undocumented gun sales and illegal straw purchases at gun shows. No significant adverse effects of these policies were observed.

  17. Spot-Welding Gun Is Easy To Use

    NASA Technical Reports Server (NTRS)

    Morgan, Gene E.; Nguyen, Francis H.

    1991-01-01

    Electrical-resistance spot-welding gun designed to produce more welds per unit time by decreasing technician's effort and fatigue. Vacuum cups on frame secure welding gun to workpiece while compressed air drives welding tip against workpiece to make spot resistance weld. When weld completed, vacuum in frame cups released so frame and gun moved to position of next spot weld.

  18. Legal status and source of offenders' firearms in states with the least stringent criteria for gun ownership.

    PubMed

    Vittes, Katherine A; Vernick, Jon S; Webster, Daniel W

    2013-02-01

    Gun possession by high-risk individuals presents a serious threat to public safety. U.S. federal law establishes minimum criteria for legal purchase and possession of firearms; many states have laws disqualifying additional categories for illegal possession. We used data from a national survey of state prison inmates to calculate: 1) the proportion of offenders, incarcerated for crimes committed with firearms in 13 states with the least restrictive firearm purchase and possession laws, who would have been prohibited if their states had stricter gun laws; and 2) the source of gun acquisition for offenders who were and were not legally permitted to purchase and possess firearms. Nearly three of ten gun offenders (73 of 253 or 28.9%) were legal gun possessors but would have been prohibited from purchasing or possessing firearms when committing their most recent offense if their states had stricter prohibitions. Offenders who were already prohibited under current law acquired their gun from a licensed dealer, where a background check is required, five times less often than offenders who were not prohibited (3.9% vs. 19.9%; χ(2)=13.31; p≤0.001). Nearly all (96.1%) offenders who were legally prohibited, acquired their gun from a supplier not required to conduct a background check. Stricter gun ownership laws would have made firearm possession illegal for many state prison inmates who used a gun to commit a crime. Requiring all gun sales to be subject to a background check would make it more difficult for these offenders to obtain guns.

  19. Gun shows across a multistate American gun market: observational evidence of the effects of regulatory policies

    PubMed Central

    Wintemute, Garen J

    2007-01-01

    Objective To describe gun shows and assess the impact of increased regulation on characteristics linked to their importance as sources of guns used in crime. Design Cross‐sectional, observational. Subjects Data were collected at a structured sample of 28 gun shows in California, which regulates these events and prohibits undocumented private party gun sales; and in Arizona, Nevada, Texas and Florida—all leading sources of California's crime guns—where these restrictions do not exist. Main outcome measures Size of shows, measured by numbers of gun vendors and people in attendance; number and nature of guns for sale by gun vendors; measures of private party gun sales and illegal surrogate (“straw”) gun purchases. Results Shows in comparison states were larger, but the number of attendees per gun vendor was higher in California. None of these differences was statistically significant. Armed attendees were more common in other states (median 5.7%, interquartile range (IQR) 3.9–10.0%) than in California (median 1.1%, IQR 0.5–2.2%), p = 0.0007. Thirty percent of gun vendors both in California and elsewhere were identifiable as licensed firearm retailers. There were few differences in the types or numbers of guns offered for sale; vendors elsewhere were more likely to sell assault weapons (34.9% and 13.3%, respectively; p = 0.001). Straw purchases were more common in the comparison states (rate ratio 6.6 (95% CI 0.9 to 49.1), p = 0.06). Conclusions California's regulatory policies were associated with a decreased incidence of anonymous, undocumented gun sales and illegal straw purchases at gun shows. No significant adverse effects of these policies were observed. PMID:17567968

  20. Exposure to seismic air gun signals causes physiological harm and alters behavior in the scallop Pecten fumatus

    PubMed Central

    McCauley, Robert D.; Fitzgibbon, Quinn P.; Hartmann, Klaas; Semmens, Jayson M.

    2017-01-01

    Seismic surveys map the seabed using intense, low-frequency sound signals that penetrate kilometers into the Earth’s crust. Little is known regarding how invertebrates, including economically and ecologically important bivalves, are affected by exposure to seismic signals. In a series of field-based experiments, we investigate the impact of exposure to seismic surveys on scallops, using measurements of physiological and behavioral parameters to determine whether exposure may cause mass mortality or result in other sublethal effects. Exposure to seismic signals was found to significantly increase mortality, particularly over a chronic (months postexposure) time scale, though not beyond naturally occurring rates of mortality. Exposure did not elicit energetically expensive behaviors, but scallops showed significant changes in behavioral patterns during exposure, through a reduction in classic behaviors and demonstration of a nonclassic “flinch” response to air gun signals. Furthermore, scallops showed persistent alterations in recessing reflex behavior following exposure, with the rate of recessing increasing with repeated exposure. Hemolymph (blood analog) physiology showed a compromised capacity for homeostasis and potential immunodeficiency, as a range of hemolymph biochemistry parameters were altered and the density of circulating hemocytes (blood cell analog) was significantly reduced, with effects observed over acute (hours to days) and chronic (months) scales. The size of the air gun had no effect, but repeated exposure intensified responses. We postulate that the observed impacts resulted from high seabed ground accelerations driven by the air gun signal. Given the scope of physiological disruption, we conclude that seismic exposure can harm scallops. PMID:28923925

  1. Gun Theft and Crime.

    PubMed

    Cook, Philip J

    2018-06-01

    Some law enforcement officials and other observers have asserted that theft is the primary source of guns to crime. In fact, the role of theft in supplying the guns used in robbery, assault, and murder is unknown, and current evidence provides little guidance about whether an effective program to reduce gun theft would reduce gun violence. The current article analyzes publicly available national data on gun theft together with a unique data set for Chicago. The results tend to support a conclusion that stolen guns play only a minor role in crime. First, publicly available data are used to calculate that thefts are only about 1% of all gun transactions nationwide. Second, an analysis of original data from Chicago demonstrates that less than 3% of crime guns recovered by the police have been reported stolen to the Chicago Police Department (CPD). If a gun is reported stolen, there is a 20% chance that it will be recovered, usually in conjunction with an arrest for illegal carrying. Less than half of those picked up with a stolen gun have a criminal record that includes violent offenses. Third, results from surveys of convicted criminals, both nationally and in Chicago, suggest that it is rare for respondents to have stolen the gun used in their most recent crime. The data on which these results are based have various shortcomings. A research agenda is proposed that would provide more certainty about the role of theft.

  2. [Reconstruction of an air-gun injury track in the neck region--a case report].

    PubMed

    Woźniak, Krzysztof; Nowaczek-Dziocha, Elzbieta; Moskała, Artur; Urbanik, Andrzej; Pohl, Jerzy

    2009-01-01

    The authors present a case of an air-gun injury of the neck region with a foreign body left in situ. The DICOM files obtained during clinical CT examination (including computed tomography angiography) gave the opportunity for three-dimensional reconstructions of the location of the pellet, neighboring blood vessels and the bullet track--essential for a successful analysis of a possible version according to the testimonies related to the critical event.

  3. FEATURE 1, SMALL GUN POSITION, VIEW FACING NORTH. Naval ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    FEATURE 1, SMALL GUN POSITION, VIEW FACING NORTH. - Naval Air Station Barbers Point, Anti-Aircraft Battery Complex-Small Gun Position, East of Coral Sea Road, northwest of Hamilton Road, Ewa, Honolulu County, HI

  4. Gun ownership and social gun culture

    PubMed Central

    Kalesan, Bindu; Villarreal, Marcos D; Keyes, Katherine M; Galea, Sandro

    2016-01-01

    We assessed gun ownership rates in 2013 across the USA and the association between exposure to a social gun culture and gun ownership. We used data from a nationally representative sample of 4000 US adults, from 50 states and District of Columbia, aged >18 years to assess gun ownership and social gun culture performed in October 2013. State-level firearm policy information was obtained from the Brady Law Center and Injury Prevention and Control Center. One-third of Americans reported owning a gun, ranging from 5.2% in Delaware to 61.7% in Alaska. Gun ownership was 2.25-times greater among those reporting social gun culture (PR=2.25, 95% CI 2.02 to 2.52) than those who did not. In conclusion, we found strong association between social gun culture and gun ownership. Gun cultures may need to be considered for public health strategies that aim to change gun ownership in the USA. PMID:26124073

  5. Wisconsin SRF Electron Gun Commissioning

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bisognano, Joseph J.; Bissen, M.; Bosch, R.

    The University of Wisconsin has completed fabrication and commissioning of a low frequency (199.6 MHz) superconducting electron gun based on a quarter wave resonator (QWR) cavity. Its concept was optimized to be the source for a CW free electron laser facility. The gun design includes active tuning and a high temperature superconducting solenoid. We will report on the status of the Wisconsin SRF electron gun program, including commissioning experience and first beam measurements.

  6. FEATURE A. CONCRETE ANTIAIRCRAFT GUN POSITION, VIEW FACING NORTHNORTHEAST. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    FEATURE A. CONCRETE ANTI-AIRCRAFT GUN POSITION, VIEW FACING NORTH-NORTHEAST. - Naval Air Station Barbers Point, Battery-Anti-Aircraft Gun Position, South of Point Cruz Road & west of Coral Sea Road, Ewa, Honolulu County, HI

  7. Crime, Culture Conflict, and the Sources of Support for Gun Control.

    ERIC Educational Resources Information Center

    Kleck, Gary

    1996-01-01

    Questions whether attitudes towards gun control are influenced primarily by exposure to high crime rates, prior victimization, and fear of crime, or result from membership in social groups hostile to gun ownership. Maintains that support for gun control is more a product of culture conflict than a response to crime. (MJP)

  8. Gun trauma and ophthalmic outcomes.

    PubMed

    Chopra, N; Gervasio, K A; Kalosza, B; Wu, A Y

    2018-04-01

    PurposeThis retrospective cohort study assesses the visual outcomes of patients who survive gunshot wounds to the head.MethodsThe Elmhurst City Hospital Trauma Registry and Mount Sinai Data Warehouse were queried for gun trauma resulting in ocular injury over a 16-year period. Thirty-one patients over 16 years of age were found who suffered a gunshot wound to the head and resultant ocular trauma: orbital fracture, ruptured globe, foreign body, or optic nerve injury. Gun types included all firearms and air guns. Nine patients were excluded due to incorrect coding or unavailable charts. Statistical analysis was performed using a simple bivariate analysis (χ 2 ).ResultsOf the 915 victims of gun trauma to the head, 27 (3.0%) sustained ocular injuries. Of the 22 patients whose records were accessible, 18 survived. Eight of the 18 surviving patients (44%) suffered long-term visual damage, defined as permanent loss of vision in at least one eye to the level of counting fingers or worse. Neither location of injury (P=0.243), nor type of gun used (P=0.296), nor cause of gun trauma (P=0.348) predicted visual loss outcome. The Glasgow Coma Scale eye response score on arrival to the hospital also did not predict visual loss outcome (P=0.793).ConclusionThere has been a dearth of research into gun trauma and even less research on the visual outcomes following gun trauma. Our study finds that survivors of gun trauma to the head suffer long-term visual damage 44% of the time after injury.

  9. Where the guns come from: the gun industry and gun commerce.

    PubMed

    Wintemute, Garen J

    2002-01-01

    Under federal law, it is illegal for youth under age 18 to purchase rifles or shotguns, and for those under age 21 to purchase handguns. However, fatality and injury statistics clearly show that guns are finding their way into young people's hands. Many of these youth obtain guns through illegal gun markets. This article focuses on how guns in the United States are manufactured, marketed, and sold. The article shows how the legal and illegal gun markets are intimately connected and make guns easily accessible to youth. Although the domestic gun manufacturing industry is relatively small and has experienced declining sales in recent years, it has significant political clout and a large market for its products, and has engaged in aggressive marketing to youth. Lax oversight of licensed firearms dealers, combined with little or no regulation of private sales between gun owners, mean that guns can quickly moved from the legal gun market into the illegal market, where they can be acquired by young people. Certain guns, especially inexpensive, poorly made small handguns, are particularly attractive to criminals and youth. The author observes that several policy innovations--including increased regulation of licensed firearms dealers, intensified screening of prospective buyers, regulation of private sales, gun licensing and registration, and bans on some types of weapons--hold promise for decreasing the flow of guns into the hands of youth.

  10. Pediatric eye injuries due to nonpowder guns in the United States, 2002-2012.

    PubMed

    Lee, Rachel; Fredrick, Douglas

    2015-04-01

    To identify epidemiologic trends in nonpowder gun-related pediatric eye injuries and to determine factors associated with severe injury requiring hospital admission. US emergency department data on pediatric eye injuries between 2002 and 2012 were reviewed using the National Electronic Injury Surveillance System. Literature review was conducted to determine trends in visual outcomes after treatment and use of eye protection. In 2012 roughly 3,161 children were treated in US emergency departments for nonpowder gun-related eye injuries. Since 2010 rates of severe nonpowder gun pediatric eye injury have increased by over 500% (P = 0.039). Specifically, while rates of hospital admission due to paintball gun eye injury have dropped precipitously (P = 0.0077), rates of admissions for air gun eye injuries have increased by over 600% since 2010 (P = 0.033). Children sustaining eye injury due to air guns are more likely to be diagnosed and admitted with foreign body or ocular puncture injury. Roughly 28% of documented cases of airsoft or BB gun-related injury had visual acuity worse than 20/50 after initial treatment. Over 98% of injuries occurred without eye protection. Air guns are rising in popularity and now account for the majority of pediatric eye injuries requiring hospital admissions. These eye injuries occur without ocular protection and may lead to permanent eye injury. Increasing regulations for eye protection, sales, and usage of air guns are needed to prevent serious pediatric eye injuries. Copyright © 2015 American Association for Pediatric Ophthalmology and Strabismus. Published by Elsevier Inc. All rights reserved.

  11. FEATURE A. CONCRETE ANTIAIRCRAFT GUN POSITION, VIEW FACING NORTH ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    FEATURE A. CONCRETE ANTI-AIRCRAFT GUN POSITION, VIEW FACING NORTH - NORTHEAST (with scale stick). - Naval Air Station Barbers Point, Battery-Anti-Aircraft Gun Position, South of Point Cruz Road & west of Coral Sea Road, Ewa, Honolulu County, HI

  12. Gun ownership and social gun culture.

    PubMed

    Kalesan, Bindu; Villarreal, Marcos D; Keyes, Katherine M; Galea, Sandro

    2016-06-01

    We assessed gun ownership rates in 2013 across the USA and the association between exposure to a social gun culture and gun ownership. We used data from a nationally representative sample of 4000 US adults, from 50 states and District of Columbia, aged >18 years to assess gun ownership and social gun culture performed in October 2013. State-level firearm policy information was obtained from the Brady Law Center and Injury Prevention and Control Center. One-third of Americans reported owning a gun, ranging from 5.2% in Delaware to 61.7% in Alaska. Gun ownership was 2.25-times greater among those reporting social gun culture (PR=2.25, 95% CI 2.02 to 2.52) than those who did not. In conclusion, we found strong association between social gun culture and gun ownership. Gun cultures may need to be considered for public health strategies that aim to change gun ownership in the USA. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  13. Ion tracking in photocathode rf guns

    NASA Astrophysics Data System (ADS)

    Lewellen, John W.

    2002-02-01

    Projected next-generation linac-based light sources, such as PERL or the TESLA free-electron laser, generally assume, as essential components of their injector complexes, long-pulse photocathode rf electron guns. These guns, due to their design rf pulse durations of many milliseconds to continuous wave, may be more susceptible to ion bombardment damage of their cathodes than conventional rf guns, which typically use rf pulses of microsecond duration. This paper explores this possibility in terms of ion propagation within the gun, and presents a basis for future study of the subject.

  14. Identification of Noise Sources and Design of Noise Reduction Measures for a Pneumatic Nail Gun

    PubMed Central

    Jayakumar, Vignesh; Zechmann, Edward

    2015-01-01

    An experimental-analytical procedure was implemented to reduce the operating noise level of a nail gun, a commonly found power tool in a construction site. The procedure is comprised of preliminary measurements, identification and ranking of major noise sources and application of noise controls. Preliminary measurements show that the impact noise transmitted through the structure and the exhaust related noise were found to be the first and second major contributors. Applying a noise absorbing foam on the outside of the nail gun body was found to be an effective noise reduction technique. One and two-volume small mufflers were designed and applied to the exhaust side of the nail gun which reduced not only the exhaust noise but also the impact noise. It was shown that the overall noise level could be reduced by as much as 3.5 dB, suggesting that significant noise reduction is possible in construction power tools without any significant increase of the cost. PMID:26366038

  15. 6. INTERIOR DETAIL OF GUN MOUNT ON TERRACE, LOOKING EAST ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    6. INTERIOR DETAIL OF GUN MOUNT ON TERRACE, LOOKING EAST (1992). - Wright-Patterson Air Force Base, Area B, Building 22, Armament Laboratory & Gun Range, On flightline between Tenth & Eleventh Streets, Dayton, Montgomery County, OH

  16. FEATURE B. MACHINE GUN POSITION WITH LEWIS MOUNT, VIEW FACING ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    FEATURE B. MACHINE GUN POSITION WITH LEWIS MOUNT, VIEW FACING NORTHWEST. - Naval Air Station Barbers Point, Battery-Machine Gun Positions, South of Point Cruz Road & west of Coral Sea Road, Ewa, Honolulu County, HI

  17. Modeling internal ballistics of gas combustion guns.

    PubMed

    Schorge, Volker; Grossjohann, Rico; Schönekess, Holger C; Herbst, Jörg; Bockholdt, Britta; Ekkernkamp, Axel; Frank, Matthias

    2016-05-01

    Potato guns are popular homemade guns which work on the principle of gas combustion. They are usually constructed for recreational rather than criminal purposes. Yet some serious injuries and fatalities due to these guns are reported. As information on the internal ballistics of homemade gas combustion-powered guns is scarce, it is the aim of this work to provide an experimental model of the internal ballistics of these devices and to investigate their basic physical parameters. A gas combustion gun was constructed with a steel tube as the main component. Gas/air mixtures of acetylene, hydrogen, and ethylene were used as propellants for discharging a 46-mm caliber test projectile. Gas pressure in the combustion chamber was captured with a piezoelectric pressure sensor. Projectile velocity was measured with a ballistic speed measurement system. The maximum gas pressure, the maximum rate of pressure rise, the time parameters of the pressure curve, and the velocity and path of the projectile through the barrel as a function of time were determined according to the pressure-time curve. The maximum gas pressure was measured to be between 1.4 bar (ethylene) and 4.5 bar (acetylene). The highest maximum rate of pressure rise was determined for hydrogen at (dp/dt)max = 607 bar/s. The muzzle energy was calculated to be between 67 J (ethylene) and 204 J (acetylene). To conclude, this work provides basic information on the internal ballistics of homemade gas combustion guns. The risk of injury to the operator or bystanders is high, because accidental explosions of the gun due to the high-pressure rise during combustion of the gas/air mixture may occur.

  18. Theoretical investigation of the microwave electron gun

    NASA Astrophysics Data System (ADS)

    Gao, J.

    1990-12-01

    In this article the microwave electron gun (rf gun) is investigated theoretically in a general way. After a brief review of the sources of emittance growth in a cavity, the optimization criteria are given and optimized electric field distributions on the axes of the cavities are found, from which cavities for a rf gun can be designed.

  19. FEATURE C. MACHINE GUN POSITION WITH REMNANT OF MOUNT, VIEW ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    FEATURE C. MACHINE GUN POSITION WITH REMNANT OF MOUNT, VIEW FACING SOUTH-SOUTHEAST. - Naval Air Station Barbers Point, Battery-Machine Gun Positions, South of Point Cruz Road & west of Coral Sea Road, Ewa, Honolulu County, HI

  20. FEATURE 1, SMALL GUN POSITION, VIEW FACING NORTH, (with scale ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    FEATURE 1, SMALL GUN POSITION, VIEW FACING NORTH, (with scale stick). - Naval Air Station Barbers Point, Anti-Aircraft Battery Complex-Small Gun Position, East of Coral Sea Road, northwest of Hamilton Road, Ewa, Honolulu County, HI

  1. FEATURE 3, LARGE GUN POSITION, SHOWING MULTIPLE COMPARTMENTS, VIEW FACING ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    FEATURE 3, LARGE GUN POSITION, SHOWING MULTIPLE COMPARTMENTS, VIEW FACING SOUTH. - Naval Air Station Barbers Point, Anti-Aircraft Battery Complex-Large Gun Position, East of Coral Sea Road, northwest of Hamilton Road, Ewa, Honolulu County, HI

  2. FEATURE B. MACHINE GUN POSITION WITH LEWIS MOUNT, VIEW FACING ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    FEATURE B. MACHINE GUN POSITION WITH LEWIS MOUNT, VIEW FACING NORTHWEST (with scale stick). - Naval Air Station Barbers Point, Battery-Machine Gun Positions, South of Point Cruz Road & west of Coral Sea Road, Ewa, Honolulu County, HI

  3. Self-bunching electron guns

    NASA Astrophysics Data System (ADS)

    Mako, Frederick M.; Len, L. K.

    1999-05-01

    We report on three electron gun projects that are aimed at power tube and injector applications. The purpose of the work is to develop robust electron guns which produce self-bunched, high-current-density beams. We have demonstrated, in a microwave cavity, self-bunching, cold electron emission, long life, and tolerance to contamination. The cold process is based on secondary electron emission. FMT has studied using simulation codes the resonant bunching process which gives rise to high current densities (0.01-5 kA/cm2), high charge bunches (up to 500 nC/bunch), and short pulses (1-100 ps) for frequencies from 1 to 12 GHz. The beam pulse width is nominally ˜5% of the rf period. The first project is the L-Band Micro-Pulse Gun (MPG). Measurements show ˜40 ps long micro-bunches at ˜20 A/cm2 without contamination due to air exposure. Lifetime testing has been carried out for about 18 months operating at 1.25 GHz for almost 24 hours per day at a repetition rate of 300 Hz and 5 μs-long macro-pulses. Approximately 5.8×1013 micro-bunches or 62,000 coulombs have passed through this gun and it is still working fine. The second project, the S-Band MPG, is now operational. It is functioning at a frequency of 2.85 GHz, a repetition rate of 30 Hz, with a 2 μs-long macro-pulse. It produces about 45 A in the macro-pulse. The third project is a 34.2 GHz frequency-multiplied source driven by an X-Band MPG. A point design was performed at an rf output power of 150 MW at 34.2 GHz. The resulting system efficiency is 53% and the gain is 60 dB. The system efficiency includes the input cavity efficiency, input driver efficiency (a 50 MW klystron at 11.4 GHz), output cavity efficiency, and the post-acceleration efficiency.

  4. FEATURE A. CONCRETE ANTIAIRCRAFT GUN POSITION, SHOWING CORAL RUBBLE BERM, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    FEATURE A. CONCRETE ANTI-AIRCRAFT GUN POSITION, SHOWING CORAL RUBBLE BERM, VIEW FACING SOUTHEAST. - Naval Air Station Barbers Point, Battery-Anti-Aircraft Gun Position, South of Point Cruz Road & west of Coral Sea Road, Ewa, Honolulu County, HI

  5. Development of neutral beam injection system by use of washer gun plasma source

    NASA Astrophysics Data System (ADS)

    Imanaka, Heizo; Kajiya, Hirotaka; Nemoto, Yuichi; Azuma, Akiyoshi; Asai, Tomoaki; Yamada, Takuma; Inomoto, Michiaki; Ono, Yasushi

    2008-11-01

    For the past ten years, we have been investigating high-beta Spherical Tokamaks (ST) formation using reconnection heating of their axial merging in the TS-4 experiment, University of Tokyo. The produced ST was observed to have the maximum beta of 50-60% right after the merging of two STs. A key issue after the formation is to maintain the produced high-beta ST over 100 Alfven times for its stability check. A new low-cost pulsed neutral beam injection (NBI) system has been arranged for its sustainment experiment. Its advantages are 1) low voltage (15kV for low-field side of ST) and high current (20A), 2) maintenance-free, 3) low-cost. The conventional filament plasma source was replaced by the washer gun to realize air-cooled and maintenance free NBI system. In its startup experiment, we already extracted the maximum beam current of 3.7A for then acceleration voltage of 10kV successfully. This result suggests that the increase in the acceleration voltage and several conditioning work will realize its designed beam parameters of 15kV, 20A.

  6. FEATURE 3, LARGE GUN POSITION, SHOWING MULTIPLE COMPARTMENTS, VIEW FACING ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    FEATURE 3, LARGE GUN POSITION, SHOWING MULTIPLE COMPARTMENTS, VIEW FACING SOUTH (with scale stick). - Naval Air Station Barbers Point, Anti-Aircraft Battery Complex-Large Gun Position, East of Coral Sea Road, northwest of Hamilton Road, Ewa, Honolulu County, HI

  7. FEATURE 3, LARGE GUN POSITION, ARMCO HUT (FEATURE 4) IN ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    FEATURE 3, LARGE GUN POSITION, ARMCO HUT (FEATURE 4) IN BACKGROUND, VIEW FACING NORTH. - Naval Air Station Barbers Point, Anti-Aircraft Battery Complex-Large Gun Position, East of Coral Sea Road, northwest of Hamilton Road, Ewa, Honolulu County, HI

  8. Counter-facing plasma guns for efficient extreme ultra-violet plasma light source

    NASA Astrophysics Data System (ADS)

    Kuroda, Yusuke; Yamamoto, Akiko; Kuwabara, Hajime; Nakajima, Mitsuo; Kawamura, Tohru; Horioka, Kazuhiko

    2013-11-01

    A plasma focus system composed of a pair of counter-facing coaxial guns was proposed as a long-pulse and/or repetitive high energy density plasma source. We applied Li as the source of plasma for improvement of the conversion efficiency, the spectral purity, and the repetition capability. For operation of the system with ideal counter-facing plasma focus mode, we changed the system from simple coaxial geometry to a multi-channel configuration. We applied a laser trigger to make synchronous multi-channel discharges with low jitter. The results indicated that the configuration is promising to make a high energy density plasma with high spectral efficiency.

  9. Simulation and optimization of a 10 A electron gun with electrostatic compression for the electron beam ion source.

    PubMed

    Pikin, A; Beebe, E N; Raparia, D

    2013-03-01

    Increasing the current density of the electron beam in the ion trap of the Electron Beam Ion Source (EBIS) in BNL's Relativistic Heavy Ion Collider facility would confer several essential benefits. They include increasing the ions' charge states, and therefore, the ions' energy out of the Booster for NASA applications, reducing the influx of residual ions in the ion trap, lowering the average power load on the electron collector, and possibly also reducing the emittance of the extracted ion beam. Here, we discuss our findings from a computer simulation of an electron gun with electrostatic compression for electron current up to 10 A that can deliver a high-current-density electron beam for EBIS. The magnetic field in the cathode-anode gap is formed with a magnetic shield surrounding the gun electrodes and the residual magnetic field on the cathode is (5 ÷ 6) Gs. It was demonstrated that for optimized gun geometry within the electron beam current range of (0.5 ÷ 10) A the amplitude of radial beam oscillations can be maintained close to 4% of the beam radius by adjusting the injection magnetic field generated by a separate magnetic coil. Simulating the performance of the gun by varying geometrical parameters indicated that the original gun model is close to optimum and the requirements to the precision of positioning the gun elements can be easily met with conventional technology.

  10. Gun Control, Gun Ownership, and Suicide Prevention.

    ERIC Educational Resources Information Center

    Lester, David

    1988-01-01

    Explored relationship between the extent of gun ownership and the strictness of gun control laws to suicide and homicide rates in the nine major geographic regions of the United States. Found gun ownership, rather than the strictness of gun control laws, was the strongest correlate of the rates of suicide and homicide by guns. (Author)

  11. Public Support for Gun Violence Prevention Policies Among Gun Owners and Non-Gun Owners in 2017.

    PubMed

    Barry, Colleen L; Webster, Daniel W; Stone, Elizabeth; Crifasi, Cassandra K; Vernick, Jon S; McGinty, Emma E

    2018-07-01

    To compare public support for 24 different gun policies between gun owners and non-gun owners in 2017. We fielded a national public opinion survey in January 2017 using an online panel to measure US adults' support for 24 gun policies. We compared support among gun owners and non-gun owners. For 23 of the 24 policies examined, most respondents supported restricting or regulating gun ownership. Only 8 of 24 policies had greater than a 10-point support gap between gun owners and non-gun owners. Policies with high public support and minimal support gaps by gun ownership status included universal background checks, greater accountability for licensed gun dealers unable to account for their inventory, higher safety training standards for concealed carry permit holders, improved reporting of records related to mental illness for background checks, gun prohibitions for persons subject to temporary domestic violence restraining orders, and gun violence restraining orders. Public Health Implications. Although there are important areas where Americans disagree on guns, large majorities of both gun owners and non-gun owners strongly support measures to strengthen US gun laws.

  12. A tapered multi-gap multi-aperture pseudospark-sourced electron gun based X-band slow wave oscillator

    NASA Astrophysics Data System (ADS)

    Kumar, N.; Lamba, R. P.; Hossain, A. M.; Pal, U. N.; Phelps, A. D. R.; Prakash, R.

    2017-11-01

    The experimental study of a tapered, multi-gap, multi-aperture pseudospark-sourced electron gun based X-band plasma assisted slow wave oscillator is presented. The designed electron gun is based on the pseudospark discharge concept and has been used to generate a high current density and high energy electron beam simultaneously. The distribution of apertures has been arranged such that the field penetration potency inside the backspace of the hollow-cathode is different while passing through the tapered gap region. This leads to non-concurrent ignition of the discharge through all the channels which is, in general, quite challenging in the case of multi-aperture plasma cathode electron gun geometries. Multiple and successive hollow cathode phases are reported from this electron gun geometry, which have been confirmed using simulations. This geometry also has led to the achievement of ˜71% fill factor inside the slow wave oscillator for an electron beam of energy of 20 keV and a beam current density in the range of 115-190 A/cm2 at a working argon gas pressure of 18 Pa. The oscillator has generated broadband microwave output in the frequency range of 10-11.7 GHz with a peak power of ˜10 kW for ˜50 ns.

  13. Ultra high vacuum test setup for electron gun

    NASA Astrophysics Data System (ADS)

    Pandiyar, M. L.; Prasad, M.; Jain, S. K.; Kumar, R.; Hannurkar, P. R.

    2008-05-01

    Ultra High Vacuum (UHV) test setup for electron gun testing has been developed. The development of next generation light sources and accelerators require development of klystron as a radio frequency power source, and in turn electron gun. This UHV electron gun test setup can be used to test the electron guns ranging from high average current, quasi-continuous wave to high peak current, single pulse etc. An electron gun has been designed, fabricated, assembled and tested for insulation up to 80 kV under the programme to develop high power klystron for future accelerators. Further testing includes the electron emission parameters characterization of the cathode, as it determines the development of a reliable and efficient electron gun with high electron emission current and high life time as well. This needs a clean ultra high vacuum to study these parameters particularly at high emission current. The cathode emission current, work function and vapour pressure of cathode surface material at high temperature studies will further help in design and development of high power electron gun The UHV electron gun test setup consists of Turbo Molecular Pump (TMP), Sputter Ion Pump (SIP), pressure gauge, high voltage and cathode power supplies, current measurement device, solenoid magnet and its power supply, residual gas analyser etc. The ultimate vacuum less than 2×10-9 mbar was achieved. This paper describes the UHV test setup for electron gun testing.

  14. The 3"/50 Gun. NAVPERS 10110.

    ERIC Educational Resources Information Center

    Bureau of Naval Personnel, Washington, DC.

    The document has been designed to provide enlisted men assigned to the 3"/50 gun with a self-study, on-the-job-training source for shipboard use. The material covered includes general description and operation, functions of various components, disassembly and reassembly, maintenance, and operational casualties of the 3"/50 gun. Detailed…

  15. Simulation and optimization of a 10 A electron gun with electrostatic compression for the electron beam ion source

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pikin, A.; Beebe, E. N.; Raparia, D.

    Increasing the current density of the electron beam in the ion trap of the Electron Beam Ion Source (EBIS) in BNL's Relativistic Heavy Ion Collider facility would confer several essential benefits. They include increasing the ions' charge states, and therefore, the ions' energy out of the Booster for NASA applications, reducing the influx of residual ions in the ion trap, lowering the average power load on the electron collector, and possibly also reducing the emittance of the extracted ion beam. Here, we discuss our findings from a computer simulation of an electron gun with electrostatic compression for electron current upmore » to 10 A that can deliver a high-current-density electron beam for EBIS. The magnetic field in the cathode-anode gap is formed with a magnetic shield surrounding the gun electrodes and the residual magnetic field on the cathode is (5 Division-Sign 6) Gs. It was demonstrated that for optimized gun geometry within the electron beam current range of (0.5 Division-Sign 10) A the amplitude of radial beam oscillations can be maintained close to 4% of the beam radius by adjusting the injection magnetic field generated by a separate magnetic coil. Simulating the performance of the gun by varying geometrical parameters indicated that the original gun model is close to optimum and the requirements to the precision of positioning the gun elements can be easily met with conventional technology.« less

  16. Homemade Firearm Suicide With Dumbbell Pipe Triggering by an Air-Compressed Gun: Case Report and Review of Literature.

    PubMed

    Le Garff, Erwan; Delannoy, Yann; Mesli, Vadim; Berthezene, Jean Marie; Morbidelli, Philippe; Hédouin, Valéry

    2015-12-01

    Firearm suicides are frequent and well described in the forensic literature, particularly in Europe and the United States. However, the use of homemade and improvised firearms is less well described. The present case reports a suicide with an original improvised gun created using an air-compressed pellet gun and a dumbbell pipe. The aims of this study were to describe the scene, the external examination of the corpse, the body scan, and the autopsy; to understand the mechanism of death; and to compare the results with a review of the forensic literature to highlight the epidemiology of homemade firearm use, the tools used for homemade and improvised firearms in suicides versus homicides, and the manners in which homemade firearms are used (homicide or suicide, particularly in complex suicide cases).

  17. Gun violence trends in movies.

    PubMed

    Bushman, Brad J; Jamieson, Patrick E; Weitz, Ilana; Romer, Daniel

    2013-12-01

    Many scientific studies have shown that the mere presence of guns can increase aggression, an effect dubbed the "weapons effect." The current research examines a potential source of the weapons effect: guns depicted in top-selling films. Trained coders identified the presence of violence in each 5-minute film segment for one-half of the top 30 films since 1950 and the presence of guns in violent segments since 1985, the first full year the PG-13 rating (age 13+) was used. PG-13-rated films are among the top-selling films and are especially attractive to youth. Results found that violence in films has more than doubled since 1950, and gun violence in PG-13-rated films has more than tripled since 1985. When the PG-13 rating was introduced, these films contained about as much gun violence as G (general audiences) and PG (parental guidance suggested for young children) films. Since 2009, PG-13-rated films have contained as much or more violence as R-rated films (age 17+) films. Even if youth do not use guns, these findings suggest that they are exposed to increasing gun violence in top-selling films. By including guns in violent scenes, film producers may be strengthening the weapons effect and providing youth with scripts for using guns. These findings are concerning because many scientific studies have shown that violent films can increase aggression. Violent films are also now easily accessible to youth (e.g., on the Internet and cable). This research suggests that the presence of weapons in films might amplify the effects of violent films on aggression.

  18. ELECTRON GUN

    DOEpatents

    Christofilos, N.C.; Ehlers, K.W.

    1960-04-01

    A pulsed electron gun capable of delivering pulses at voltages of the order of 1 mv and currents of the order of 100 amperes is described. The principal novelty resides in a transformer construction which is disposed in the same vacuum housing as the electron source and accelerating electrode structure of the gun to supply the accelerating potential thereto. The transformer is provided by a plurality of magnetic cores disposed in circumferentially spaced relation and having a plurality of primary windings each inductively coupled to a different one of the cores, and a helical secondary winding which is disposed coaxially of the cores and passes therethrough in circumferential succession. Additional novelty resides in the disposition of the electron source cathode filament input leads interiorly of the transformer secondary winding which is hollow, as well as in the employment of a half-wave filament supply which is synchronously operated with the transformer supply such that the transformer is pulsed during the zero current portions of the half-wave cycle.

  19. Gun Play

    ERIC Educational Resources Information Center

    Mechling, Jay

    2008-01-01

    Biology and the particular gun culture of the United States come together to explain the persistent and powerful attraction of American boys to both real guns and toy guns. The 1990s saw adults begin to conflate "the gun problem" with "the boy problem," sparking attempts (largely failed) to banish toy guns from homes and…

  20. State Firearm Laws and Interstate Transfer of Guns in the USA, 2006-2016.

    PubMed

    Collins, Tessa; Greenberg, Rachael; Siegel, Michael; Xuan, Ziming; Rothman, Emily F; Cronin, Shea W; Hemenway, David

    2018-06-01

    In a cross-sectional, panel study, we examined the relationship between state firearm laws and the extent of interstate transfer of guns, as measured by the percentage of crime guns recovered in a state and traced to an in-state source (as opposed to guns recovered in a state and traced to an out-of-state source). We used 2006-2016 data on state firearm laws obtained from a search of selected state statutes and 2006-2016 crime gun trace data from the Bureau of Alcohol, Tobacco, Firearms, and Explosives. We examined the relationship between state firearm laws and interstate transfer of guns using annual data from all 50 states during the period 2006-2016 and employing a two-way fixed effects model. The primary outcome variable was the percentage of crime guns recovered in a state that could be traced to an original point of purchase within that state as opposed to another state. The main exposure variables were eight specific state firearm laws pertaining to dealer licensing, sales restrictions, background checks, registration, prohibitors for firearm purchase, and straw purchase of guns. Four laws were independently associated with a significantly lower percentage of in-state guns: a waiting period for handgun purchase, permits required for firearm purchase, prohibition of firearm possession by people convicted of a violent misdemeanor, and a requirement for relinquishment of firearms when a person becomes disqualified from owning them. States with a higher number of gun laws had a lower percentage of traced guns to in-state dealers, with each increase of one in the total number of laws associated with a decrease of 1.6 percentage points in the proportion of recovered guns that were traced to an in-state as opposed to an out-of-state source. Based on an examination of the movement patterns of guns across states, the overall observed pattern of gun flow was out of states with weak gun laws and into states with strong gun laws. These findings indicate that certain

  1. An X-Band Gun Test Area at SLAC

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Limborg-Deprey, C.; Adolphsen, C.; Chu, T.S.

    The X-Band Test Area (XTA) is being assembled in the NLCTA tunnel at SLAC to serve as a test facility for new RF guns. The first gun to be tested will be an upgraded version of the 5.6 cell, 200 MV/m peak field X-band gun designed at SLAC in 2003 for the Compton Scattering experiment run in ASTA. This new version includes some features implemented in 2006 on the LCLS gun such as racetrack couplers, increased mode separation and elliptical irises. These upgrades were developed in collaboration with LLNL since the same gun will be used in an injector formore » a LLNL Gamma-ray Source. Our beamline includes an X-band acceleration section which takes the electron beam up to 100 MeV and an electron beam measurement station. Other X-Band guns such as the UCLA Hybrid gun will be characterized at our facility.« less

  2. Low Emittance Guns for the ILC Polarized Electron Beam

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Clendenin, J. E.; Brachmann, A.; Ioakeimidi, K.

    Polarized electron beams generated by DC guns are routinely available at several accelerators including JLAB, Mainz and SLAC. These guns operate with a cathode bias on the order of -100 kV. To minimize space charge effects, relatively long bunches are generated at the gun and then compressed longitudinally external to the gun just before and during initial acceleration. For linear colliders, this compression is accomplished using a combination of rf bunchers. For the basic design of the International Linear Collider (ILC), a 120 kV DC photocathode gun is used to produce a series of nanosecond bunches that are each compressedmore » by two sub-harmonic bunchers (SHBs) followed by an L-band buncher and capture section. The longitudinal bunching process results in a significantly higher emittance than produced by the gun alone. While high-energy experiments using polarized beams are not generally sensitive to the source emittance, there are several benefits to a lower source emittance including a simpler more efficient injector system and a lower radiation load during transport especially at bends as at the damping ring. For the ILC, the SHBs could be eliminated if the voltage of the gun is raised sufficiently. Simulations using the General Particle Tracer (GPT) package indicate that a cathode bias voltage of {>=}200 kV should allow both SHBs to be operated at 433 or even 650 MHz, while {>=}500 kV would be required to eliminate the SHBs altogether. Simulations can be used to determine the minimum emittance possible if the injector is designed for a given increased voltage. A possible alternative to the DC gun is an rf gun. Emittance compensation, routinely used with rf guns, is discussed for higher-voltage DC guns.« less

  3. Low Emittance Guns for the ILC Polarized Electron Beam

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Clendenin, J.E.; Brachmann, A.; Ioakeimidi, K.

    Polarized electron beams generated by DC guns are routinely available at several accelerators including JLAB, Mainz and SLAC. These guns operate with a cathode bias on the order of -100 kV. To minimize space charge effects, relatively long bunches are generated at the gun and then compressed longitudinally external to the gun just before and during initial acceleration. For linear colliders, this compression is accomplished using a combination of rf bunchers. For the basic design of the International Linear Collider (ILC), a 120 kV DC photocathode gun is used to produce a series of nanosecond bunches that are each compressedmore » by two sub-harmonic bunchers (SHBs) followed by an L-band buncher and capture section. The longitudinal bunching process results in a significantly higher emittance than produced by the gun alone. While high-energy experiments using polarized beams are not generally sensitive to the source emittance, there are several benefits to a lower source emittance including a simpler more efficient injector system and a lower radiation load during transport especially at bends as at the damping ring. For the ILC, the SHBs could be eliminated if the voltage of the gun is raised sufficiently. Simulations using the General Particle Tracer (GPT) package indicate that a cathode bias voltage of {ge}200 kV should allow both SHBs to be operated at 433 or even 650 MHz, while {ge}500 kV would be required to eliminate the SHBs altogether. Simulations can be used to determine the minimum emittance possible if the injector is designed for a given increased voltage. A possible alternative to the DC gun is an rf gun. Emittance compensation, routinely used with rf guns, is discussed for higher-voltage DC guns.« less

  4. Sandia 25-meter compressed helium/air gun

    NASA Astrophysics Data System (ADS)

    Setchell, R. E.

    1982-04-01

    For nearly twenty years the Sandia 25-meter compressed gas gun has been an important tool for studying condensed materials subjected to transient shock compression. Major system modifications are now in progress to provide new control, instrumentation, and data acquisition capabilities. These features will ensure that the facility can continue as an effective means of investigating a variety of physical and chemical processes in shock-compressed solids.

  5. Gun Shows and Gun Violence: Fatally Flawed Study Yields Misleading Results

    PubMed Central

    Hemenway, David; Webster, Daniel; Pierce, Glenn; Braga, Anthony A.

    2010-01-01

    A widely publicized but unpublished study of the relationship between gun shows and gun violence is being cited in debates about the regulation of gun shows and gun commerce. We believe the study is fatally flawed. A working paper entitled “The Effect of Gun Shows on Gun-Related Deaths: Evidence from California and Texas” outlined this study, which found no association between gun shows and gun-related deaths. We believe the study reflects a limited understanding of gun shows and gun markets and is not statistically powered to detect even an implausibly large effect of gun shows on gun violence. In addition, the research contains serious ascertainment and classification errors, produces results that are sensitive to minor specification changes in key variables and in some cases have no face validity, and is contradicted by 1 of its own authors’ prior research. The study should not be used as evidence in formulating gun policy. PMID:20724672

  6. Gun shows and gun violence: fatally flawed study yields misleading results.

    PubMed

    Wintemute, Garen J; Hemenway, David; Webster, Daniel; Pierce, Glenn; Braga, Anthony A

    2010-10-01

    A widely publicized but unpublished study of the relationship between gun shows and gun violence is being cited in debates about the regulation of gun shows and gun commerce. We believe the study is fatally flawed. A working paper entitled "The Effect of Gun Shows on Gun-Related Deaths: Evidence from California and Texas" outlined this study, which found no association between gun shows and gun-related deaths. We believe the study reflects a limited understanding of gun shows and gun markets and is not statistically powered to detect even an implausibly large effect of gun shows on gun violence. In addition, the research contains serious ascertainment and classification errors, produces results that are sensitive to minor specification changes in key variables and in some cases have no face validity, and is contradicted by 1 of its own authors' prior research. The study should not be used as evidence in formulating gun policy.

  7. Encyclopedia of Gun Control and Gun Rights.

    ERIC Educational Resources Information Center

    Utter, Glenn H.

    This reference volume provides information on gun control and gun rights, including resources on the debate surrounding the Second Amendment and individuals and organizations focused on gun issues, along with statutes, court cases, events, and publications surrounding this current topic. Highlighted are the important organizations and their…

  8. 14. BUILDING NO. 445, PHYSICS LAB (FORMERLY GUN BAG LOADING), ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    14. BUILDING NO. 445, PHYSICS LAB (FORMERLY GUN BAG LOADING), LOOKING EAST AT SOUTHWEST END OF BUILDING. HVAC EQUIPMENT LOCATED OUTDOORS IN FOREGROUND. DUCTS CONDUCT HOT OR COLD AIR INDOORS. ROUND PIPES ARE INSULATED STEAM LINES. BUILDING NO. 448, ORDNANCE FACILITY, IN BACKGROUND. - Picatinny Arsenal, 400 Area, Gun Bag Loading District, State Route 15 near I-80, Dover, Morris County, NJ

  9. Brain injury due to air gun shot: report of three adult cases.

    PubMed

    Dalgıç, Ali; Okay, Onder; Ergüngör, Fikret Mehmet; Uçkun, Ozhan; Nacar, Osman Arıkan; Yıldırım, Ali Erdem

    2010-09-01

    Air guns (AGs) are arms that use air or another compressed gas to propel a projectile. Generally, brain injury may occur in children due to their incomplete skull development; however, the less-resistant and thin region of the skull in adults may also be penetrated by an AG shot. In this paper, we present three adult cases treated in our clinic for brain injury caused by an AG. The first case had brain and skull damage related to the high pressure of the compressed gas, and the others additionally had foreign bodies in their brain. All of the patients were operated. Two were discharged without neurological deficit; the third case had a permanent slight hemiparesis. Average follow-up was 11 months and no abscess formation was observed in this period. AGs are known as low-velocity arms; however, they have the potential to cause brain injury, and brain penetration may occur especially in the relatively less resistant and thin sites of the skull such as the orbit and temporal and occipital bones. As cerebrospinal fluid leakage is one of the expected conditions, urgent surgery is usually required.

  10. State Gun Law Environment and Youth Gun Carrying in the United States.

    PubMed

    Xuan, Ziming; Hemenway, David

    2015-11-01

    Gun violence and injuries pose a substantial threat to children and youth in the United States. Existing evidence points to the need for interventions and policies for keeping guns out of the hands of children and youth. (1) To examine the association between state gun law environment and youth gun carrying in the United States, and (2) to determine whether adult gun ownership mediates this association. This was a repeated cross-sectional observational study design with 3 years of data on youth gun carrying from US states. The Youth Risk Behavior Survey comprises data of representative samples of students in grades 9 to 12 from biennial years of 2007, 2009, and 2011. We hypothesized that states with more restrictive gun laws have lower rates of youth gun carrying, and this association is mediated by adult gun ownership. State gun law environment as measured by state gun law score. Youth gun carrying was defined as having carried a gun on at least 1 day during the 30 days before the survey. In the fully adjusted model, a 10-point increase in the state gun law score, which represented a more restrictive gun law environment, was associated with a 9% decrease in the odds of youth gun carrying (adjusted odds ratio [AOR], 0.91 [95% CI, 0.86-0.96]). Adult gun ownership mediated the association between state gun law score and youth gun carrying (AOR, 0.94 [ 95% CI, 0.86-1.01], with 29% attenuation of the regression coefficient from -0.09 to -0.07 based on bootstrap resampling). More restrictive overall gun control policies are associated with a reduced likelihood of youth gun carrying. These findings are relevant to gun policy debates about the critical importance of strengthening overall gun law environment to prevent youth gun carrying.

  11. Two-dimensional computational modeling of high-speed transient flow in gun tunnel

    NASA Astrophysics Data System (ADS)

    Mohsen, A. M.; Yusoff, M. Z.; Hasini, H.; Al-Falahi, A.

    2018-03-01

    In this work, an axisymmetric numerical model was developed to investigate the transient flow inside a 7-meter-long free piston gun tunnel. The numerical solution of the gun tunnel was carried out using the commercial solver Fluent. The governing equations of mass, momentum, and energy were discretized using the finite volume method. The dynamic zone of the piston was modeled as a rigid body, and its motion was coupled with the hydrodynamic forces from the flow solution based on the six-degree-of-freedom solver. A comparison of the numerical data with the theoretical calculations and experimental measurements of a ground-based gun tunnel facility showed good agreement. The effects of parameters such as working gases and initial pressure ratio on the test conditions in the facility were examined. The pressure ratio ranged from 10 to 50, and gas combinations of air-air, helium-air, air-nitrogen, and air-CO2 were used. The results showed that steady nozzle reservoir conditions can be maintained for a longer duration when the initial conditions across the diaphragm are adjusted. It was also found that the gas combination of helium-air yielded the highest shock wave strength and speed, but a longer test time was achieved in the test section when using the CO2 test gas.

  12. Gun threats against and self-defense gun use by California adolescents.

    PubMed

    Hemenway, David; Miller, Matthew

    2004-04-01

    To assess hostile gun use against and self-defense gun use by adolescents. We use random-digit-dial telephone survey data collected from approximately 5800 California adolescents, aged 12 through 17 years, between November 1, 2000, and October 31, 2001. The prevalence and correlates of reported hostile gun use against and self-defense gun use by adolescents, as well as qualitative information about these 2 types of gun uses. Correlates include age, sex, ethnicity, smoking, alcoholic binge drinking, threatening others, parents knowing their adolescent's whereabouts in the afternoon after school, attending school, area urbanization and poverty level, and living in a household with a gun. Approximately 4% of the adolescents reported ever having been threatened with a gun; only 0.3% reported using a gun in self-defense. Boys, smokers, adolescents who threatened others, and adolescents whose parents knew little about their whereabouts in the afternoon after school were more likely to report being threatened with a gun. Most episodes of self-defense gun use seem to be hostile interactions between adolescents with weapons. Far more California adolescents are threatened with a gun than use a gun in self-defense. Self-defense gun use is rare; many of the reported self-defense gun uses seem to be armed confrontations.

  13. Investigating the link between gun possession and gun assault.

    PubMed

    Branas, Charles C; Richmond, Therese S; Culhane, Dennis P; Ten Have, Thomas R; Wiebe, Douglas J

    2009-11-01

    We investigated the possible relationship between being shot in an assault and possession of a gun at the time. We enrolled 677 case participants that had been shot in an assault and 684 population-based control participants within Philadelphia, PA, from 2003 to 2006. We adjusted odds ratios for confounding variables. After adjustment, individuals in possession of a gun were 4.46 (P < .05) times more likely to be shot in an assault than those not in possession. Among gun assaults where the victim had at least some chance to resist, this adjusted odds ratio increased to 5.45 (P < .05). On average, guns did not protect those who possessed them from being shot in an assault. Although successful defensive gun uses occur each year, the probability of success may be low for civilian gun users in urban areas. Such users should reconsider their possession of guns or, at least, understand that regular possession necessitates careful safety countermeasures.

  14. rf traveling-wave electron gun for photoinjectors

    NASA Astrophysics Data System (ADS)

    Schaer, Mattia; Citterio, Alessandro; Craievich, Paolo; Reiche, Sven; Stingelin, Lukas; Zennaro, Riccardo

    2016-07-01

    The design of a photoinjector, in particular that of the electron source, is of central importance for free electron laser (FEL) machines where a high beam brightness is required. In comparison to standard designs, an rf traveling-wave photocathode gun can provide a more rigid beam with a higher brightness and a shorter pulse. This is illustrated by applying a specific optimization procedure to the SwissFEL photoinjector, for which a brightness improvement up to a factor 3 could be achieved together with a double gun output energy compared to the reference setup foreseeing a state-of-the-art S-band rf standing-wave gun. The higher brightness is mainly given by a (at least) double peak current at the exit of the gun which brings benefits for both the beam dynamics in the linac and the efficiency of the FEL process. The gun design foresees an innovative coaxial rf coupling at both ends of the structure which allows a solenoid with integrated bucking coil to be placed around the cathode in order to provide the necessary focusing right after emission.

  15. Gun Safety

    MedlinePlus

    Many U.S. households have guns, but they can cause harm if not handled properly. Here are some things you can do to keep yourself and ... safe: Teach children that they shouldn't touch guns and that if they see a gun, to ...

  16. The Mystery of the Gun Turret in the Desert

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hoffman, R. D.

    The mystery of the gun turret in the desert began with an ingenious idea: to develop a reusable open-air line of sight diagnostic device to support LLNL’s early nuclear weapons development efforts. Obtained from the Mare Island Navy Shipyard (MINS) in January 1957, the gun turret traveled by ship to the Naval Construction Battalion base at Port Hueneme, California, and then by truck to Area 2 in the Yucca Flats valley at the Nevada Nuclear Security Site (NNSS).

  17. Gun utopias? Firearm access and ownership in Israel and Switzerland

    PubMed Central

    Rosenbaum, Janet

    2011-01-01

    The 2011 attempted assassination of a US representative renewed the national gun control debate. Gun advocates claim that mass-casualty events are mitigated and deterred with three policies: (1) permissive gun laws, (2) widespread gun ownership, (3) encouragement of armed civilians who can intercept shooters, and cite Switzerland and Israel as exemplars. We evaluate these claims with analysis of International Crime Victimization Survey (ICVS) data and translation of laws and original source material. Swiss and Israeli laws limit firearm ownership and require permit renewal 14 times annually. ICVS analysis finds that the US has more firearms per capita and per household than either country. Switzerland and Israel curtail off-duty soldiers firearm access to prevent firearm deaths. Suicide among soldiers decreased by 40% after the Israeli armys 2006 reforms. Compared with the US, Switzerland and Israel have lower gun ownership and stricter gun laws, and their policies discourage personal gun ownership. PMID:22089893

  18. Gun utopias? Firearm access and ownership in Israel and Switzerland.

    PubMed

    Rosenbaum, Janet E

    2012-02-01

    The 2011 attempted assassination of a US representative renewed the national gun control debate. Gun advocates claim mass-casualty events are mitigated and deterred with three policies: (a) permissive gun laws, (b) widespread gun ownership, (c) and encouragement of armed civilians who can intercept shooters. They cite Switzerland and Israel as exemplars. We evaluate these claims with analysis of International Crime Victimization Survey (ICVS) data and translation of laws and original source material. Swiss and Israeli laws limit firearm ownership and require permit renewal one to four times annually. ICVS analysis finds the United States has more firearms per capita and per household than either country. Switzerland and Israel curtail off-duty soldiers' firearm access to prevent firearm deaths. Suicide among soldiers decreased by 40 per cent after the Israeli army's 2006 reforms. Compared with the United States, Switzerland and Israel have lower gun ownership and stricter gun laws, and their policies discourage personal gun ownership.

  19. Strong gun laws are not enough: the need for improved enforcement of secondhand gun transfer laws in Massachusetts.

    PubMed

    Braga, Anthony A; Hureau, David M

    2015-10-01

    Research suggests that an overwhelming majority of crime guns were transferred by private sellers before recovery by law enforcement. Unfortunately, most states do not regulate these transactions. This study examines whether analyses of state-level private transfer data could be used to develop interventions to reduce the supply of handguns to violent criminals. Traced Boston crime handguns first sold at Massachusetts license dealers were matched to state secondhand gun transfer data. Logistic regression and descriptive statistics were used to analyze the characteristics of recovered crime guns and in-state primary and secondary market transaction patterns. For crime handguns with records of secondary market transactions in Massachusetts, many rapidly move from private transfer to recovery by the police. Unfortunately, important transaction data on the in-state sources of nearly 63% of recovered handguns were not readily available to law enforcement agencies. Data on private transfers of guns could be used to prevent violent injuries by reducing criminal access. However, the passage of strong private transfer gun laws needs to be accompanied by investments in the vigorous enforcement of reporting requirements. Copyright © 2015 Elsevier Inc. All rights reserved.

  20. The Gun Dispute.

    ERIC Educational Resources Information Center

    Spitzer, Robert J.

    1999-01-01

    Explores the debate over gun ownership and gun control in the United States, focusing on the historic place of guns in U.S. society. The current national mood is more receptive than ever to restricting and regulating adolescent access to guns in light of recent school shootings. (SLD)

  1. Laser-free RF-gun as a combined source of THz and ps-sub-ps X-rays

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Agustsson, R.; Boucher, S.; Finn, O.

    A coherent, mm-sub-mm-wave source driven by a RF electron gun is proposed for wide research applications as well as auxiliary inspection and screening, safe imaging, cancer diagnostics, surface defectoscopy, and enhanced time-domain spectroscopy. It allows generation of high peak and average THz-sub-THz radiation power provided by beam pre-bunching and chirping in the RF gun followed by microbunching in magnetic compressor, and resonant Cherenkov radiation of an essentially flat beam in a robust, ~inch-long, planar, mm-sub-mm gap structure. The proof-of-principle has been successfully demonstrated in Phase I on a 5 MeV beam of L-band thermionic injector of Idaho Accelerator Center. Themore » system can also deliver an intense, ps-sub-ps bursts of low-to-moderate dose of relativistic electrons and X-ray radiation produced by the same beam required for pulsed radiolysis as well as to enhance screening efficiency, throughput and safety.« less

  2. Laser-free RF-gun as a combined source of THz and ps-sub-ps X-rays

    DOE PAGES

    Agustsson, R.; Boucher, S.; Finn, O.; ...

    2015-01-01

    A coherent, mm-sub-mm-wave source driven by a RF electron gun is proposed for wide research applications as well as auxiliary inspection and screening, safe imaging, cancer diagnostics, surface defectoscopy, and enhanced time-domain spectroscopy. It allows generation of high peak and average THz-sub-THz radiation power provided by beam pre-bunching and chirping in the RF gun followed by microbunching in magnetic compressor, and resonant Cherenkov radiation of an essentially flat beam in a robust, ~inch-long, planar, mm-sub-mm gap structure. The proof-of-principle has been successfully demonstrated in Phase I on a 5 MeV beam of L-band thermionic injector of Idaho Accelerator Center. Themore » system can also deliver an intense, ps-sub-ps bursts of low-to-moderate dose of relativistic electrons and X-ray radiation produced by the same beam required for pulsed radiolysis as well as to enhance screening efficiency, throughput and safety.« less

  3. Gun Safety (For Kids)

    MedlinePlus

    ... Staying Safe Videos for Educators Search English Español Gun Safety KidsHealth / For Kids / Gun Safety What's in ... from guns outside the home. If You Have Guns in Your Home If your parents keep guns ...

  4. Interior of southeast gun chamber (labeled "Gun Turret No. Two), ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Interior of southeast gun chamber (labeled "Gun Turret No. Two), showing gun mounting pad, wall rings, small niche, and opening to outside - U.S. Naval Base, Pearl Harbor, Battery Adair, Princeton Place, Pearl City, Honolulu County, HI

  5. Methods for coating conduit interior surfaces utilizing a thermal spray gun with extension arm

    DOEpatents

    Moore, Karen A.; Zatorski, Raymond A.

    2007-10-02

    Systems and methods for applying a coating to an interior surface of a conduit. In one embodiment, a spray gun configured to apply a coating is attached to an extension arm which may be inserted into the bore of a pipe. The spray gun may be a thermal spray gun adapted to apply a powder coating. An evacuation system may be used to provide a volume area of reduced air pressure for drawing overspray out of the pipe interior during coating. The extension arm as well as the spray gun may be cooled to maintain a consistent temperature in the system, allowing for more consistent coating.

  6. Note: Characteristic beam parameter for the line electron gun.

    PubMed

    Iqbal, M; Islam, G U; Zhou, Z; Chi, Y

    2013-11-01

    We have optimized the beam parameters of line source electron gun using Stanford Linear Accelerator Centre electron beam trajectory program (EGUN), utilizing electrostatic focusing only. We measured minimum beam diameter as 0.5 mm that corresponds to power density of 68.9 kW/cm(2) at 13.5 mm in the post-anode region which is more than two-fold (33 kW/cm(2)), of the previously reported results. The gun was operated for the validation of the theoretical results and found in good agreement. The gun is now without any magnetic and electrostatic focusing thus much simpler and more powerful.

  7. Note: Characteristic beam parameter for the line electron gun

    NASA Astrophysics Data System (ADS)

    Iqbal, M.; Islam, G. U.; Zhou, Z.; Chi, Y.

    2013-11-01

    We have optimized the beam parameters of line source electron gun using Stanford Linear Accelerator Centre electron beam trajectory program (EGUN), utilizing electrostatic focusing only. We measured minimum beam diameter as 0.5 mm that corresponds to power density of 68.9 kW/cm2 at 13.5 mm in the post-anode region which is more than two-fold (33 kW/cm2), of the previously reported results. The gun was operated for the validation of the theoretical results and found in good agreement. The gun is now without any magnetic and electrostatic focusing thus much simpler and more powerful.

  8. 5. GUN MOUNT ON TERRACE, EAST VIEW (1992). WrightPatterson ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    5. GUN MOUNT ON TERRACE, EAST VIEW (1992). - Wright-Patterson Air Force Base, Area B, Building 71, Power Plant Engine Test Torque Stands, Seventh Street between D & G Streets, Dayton, Montgomery County, OH

  9. A Discussion on Personnel Exposure to Posttest Byproducts from a 50-cal. Light Gas Gun

    NASA Technical Reports Server (NTRS)

    Henderson, Don; Rodriquez, Karen

    2007-01-01

    In January of 2002, employees working in the Hypervelocity Test Facility (HTF) at White Sands Test Facility (WSTF) began to notice common physical complaints. These included loss of smell, loss of taste, skin irritation, a burning sensation of the mucus membranes, and redness and chapping of the lips. These conditions extended to home during the weekends and throughout holiday breaks as well. Concerns about air contaminants were raised with regard to the operation of the .50-cal. two-stage light gas gun (2SLGG). Employees suspected that these conditions might be caused by air contaminants from small leaks at the gun pump tube joint at the breech, and exhaust gas entrainment into the WAC systems. The WSTF Industrial Hygienist (IH) was notified and samples were collected using the MIRAN infrared spectrometer (real time) air sampler on 08 January 2002 at the SO-cal. gun. The results from this screening test suggested the need for more detailed investigations with analytical sampling and analysis.

  10. Geophysical investigation of the pressure field produced by water guns at a pond site in La Crosse, Wisconsin

    USGS Publications Warehouse

    Adams, Ryan F.; Morrow, William S.

    2015-09-03

    The July 2013 study consisted of three scenarios: fish behavior, single gun assessment, and experimental barrier evaluation. The fish behavior scenario simulated the pond conditions from previous studies. Two 80-in3 water guns were fired in the south end of the testing pond. Pressures essentially doubled from the testing of the single 80-in3 water gun. The single gun assessment scenario sought to replicate the setup of the 80-in3 scenario in September 2012, but with additional sensors to better define the pressure field. The 5-lb/in2 target pressure field continued to show a radius ranging from 40 to 45 feet, dependent on the pressure of the input air. The final scenario, the experimental barrier evaluation, showed that a two-dimensional continuous plane of 5 lb/in2 can be created between two 80-in3 water guns to a separation of 99 feet and a depth of 6.5 feet with 1,500 lb/in2 of input air.

  11. Temporal association between federal gun laws and the diversion of guns to criminals in Milwaukee.

    PubMed

    Webster, Daniel W; Vernick, Jon S; Bulzacchelli, Maria T; Vittes, Katherine A

    2012-02-01

    The practices of licensed gun dealers can threaten the safety of urban residents by facilitating the diversion of guns to criminals. In 2003, changes to federal law shielded gun dealers from the release of gun trace data and provided other protections to gun dealers. The 14-month period during which the dealer did not sell junk guns was associated with a 68% reduction in the diversion of guns to criminals within a year of sale by the dealer and a 43% increase in guns diverted to criminals following sales by other dealers. The laws were associated with a 203% increase in the number of guns diverted to criminals within a year of sale by the gun store, which was the focus of this study. Policies which affect gun dealer accountability appeared to influence the diversion of guns to criminals.

  12. Effects of Exposure to Gun Violence in Movies on Children's Interest in Real Guns.

    PubMed

    Dillon, Kelly P; Bushman, Brad J

    2017-11-01

    More US children die by accidental gun use than children in other developed countries. One factor that can influence children's interest in guns is exposure to media containing guns. To test whether children who see a movie containing guns will handle a real gun longer and will pull the trigger more times than children who see the same movie not containing guns. One hundred four children aged 8 to 12 years recruited through advertisements were randomly assigned in pairs to watch a 20-minute PG-rated movie containing or not containing guns in a university laboratory. Children then played with toys and games in a room for 20 minutes while being video recorded. A cabinet in the room contained a real (disabled) gun with a sensor counting trigger pulls. Recordings were coded for the time spent holding the gun and in aggressive play. Data were collected from July 15, 2015, through January 1, 2016, and analyzed using generalized estimating equations (Tweedie log-link for time spent holding the gun; Poisson log-link for pulling the trigger). The 2 main outcomes were time spent holding the gun and the number of trigger pulls. Control variables included sex, age, trait aggressiveness, exposure to violent media, interest in guns, and number of guns at home. Among the 104 study participants (62 boys [59.6%] and 42 girls [40.4%]; mean (SD) age, 9.9 [1.5] years), the adjusted median number of trigger pulls among children who saw the movie containing guns was 2.8 (interquartile range [IQR], 0.2-2.8) compared with 0.01 (IQR, 0.01-0.2) among children who saw the movie not containing guns (adjusted odds ratio, 22.3; 95% CI, 6.0-83.4; P < .001). The adjusted median number of seconds spent holding the gun among children who saw a movie containing guns was 53.1 (IQR, 35.5-53.1) compared with 11.1 (IQR, 10.7-16.7) among children who saw the movie not containing guns (adjusted odds ratio, 3.0; 95% CI, 0.9-9.9; P = .07). Qualitative analyses on 4 pairs from each condition found

  13. Subcaliber Guns

    DTIC Science & Technology

    1988-06-16

    310-6 11. TITLE (Include Security Classification) "SUBCALIBER GUNS " 12. PERSONAL AUTHOR(S) 13a. TYPE OF REPORT 13b. TIME COVERED 14. DATE OF REPORT...necessary and identify by block number) FIELD GROUP SUB-GROUP 4Large caliber weapons, .,Subcaliber guns (" J-) Parent weapons.; Small caliber weapons’y...19, ABSTRACT (Continue on reverse if necessary and identify by block number) Provides procedures for determining the suitability of subcaliber guns

  14. Survey of SRF guns

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Belomestnykh, S.

    Developing Superconducting RF (SRF) electron guns is an active field with several laboratories working on different gun designs. While the first guns were based on elliptic cavity geometries, Quarter Wave Resonator (QWR) option is gaining popularity. QWRs are especially well suited for producing beams with high charge per bunch. In this talk we will describe recent progress in developing both types of SRF guns. SRF guns made excellent progress in the last two years. Several guns generated beams and one, at HZDR, injected beam into an accelerator. By accomplishing this, HZDR/ELBE gun demonstrated feasibility of the SRF gun concept withmore » a normal-conducting Cs{sub 2}Te cathode. The cathode demonstrated very good performance with the lifetime of {approx}1 year. However, for high average current/high bunch charge operation CsK{sub 2}Sb is preferred as it needs green lasers, unlike UV laser for the Cs{sub 2}Te, which makes it easier to build laser/optics systems. Other high QE photocathodes are being developed for SRF guns, most notably diamond-amplified photocathode. Several QWR guns are under development with one producing beam already. They are very promising for high bunch charge operation. The field is very active and we should expect more good results soon.« less

  15. Electrostatic focusing of directly heated linear filament gun using EGUN

    NASA Astrophysics Data System (ADS)

    Iqbal, Munawar; Lodhi, M. A. K.; Majeed, Zahid; Batani, Dimitri

    2011-06-01

    This paper presents the optimization of a line source rectangular electron gun using electrostatic focusing. We optimized the gun by shaping the configuration of its electrodes in order to achieve the desired focusing characteristics, namely maximum focusing distance and minimum beam spread. The optimization has been carried out using the software EGUN. We have also simplified the gun design using only one focusing electrode at the same potential as that of the cathode and by avoiding magnetic focusing field, separate focusing electrodes and additional power supply, thus minimizing the cost without any loss in its accuracy and efficient performance. This gun with the optimum configuration was used in actual experiment and the results of the simulation were compared with the experimental measurements.

  16. Note: Characteristic beam parameter for the line electron gun

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Iqbal, M.; Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049; Islam, G. U.

    We have optimized the beam parameters of line source electron gun using Stanford Linear Accelerator Centre electron beam trajectory program (EGUN), utilizing electrostatic focusing only. We measured minimum beam diameter as 0.5 mm that corresponds to power density of 68.9 kW/cm{sup 2} at 13.5 mm in the post-anode region which is more than two-fold (33 kW/cm{sup 2}), of the previously reported results. The gun was operated for the validation of the theoretical results and found in good agreement. The gun is now without any magnetic and electrostatic focusing thus much simpler and more powerful.

  17. Guns and Violence. Current Controversies.

    ERIC Educational Resources Information Center

    Kim, Henny H., Ed.

    This book focuses on gun violence and gun control, presenting both sides of arguments about firearms ownership and gun control. Each of five chapters poses a question about gun control and provides answers for both sides of the question. The following essays are included: (1) "Gun Violence Is Becoming an Epidemic" (Bob Herbert); (2) "Gun Violence…

  18. Reduction of Gun Erosion and Correlation of Gun Erosion Measurements

    NASA Technical Reports Server (NTRS)

    Bogdanoff, Dave; Wercinski, Paul (Technical Monitor)

    1997-01-01

    Gun barrel erosion is serious problem with two-stage light gas guns. Excessive barrel erosion can lead to poor or failed launches and frequent barrel changes, with the corresponding down time. Also, excessive barrel erosion can limit the maximum velocity obtainable by loading down the hydrogen working gas with eroded barrel material. Guided by a CFD code, the operating conditions of the Ames 0.5-inch gun were modified to reduce barrel erosion. The changes implemented included: (1) reduction in the piston mass, powder mass and hydrogen fill pressure; and (2) reduction in pump tube volume, while maintaining hydrogen mass. The latter change was found, in particular, to greatly reduce barrel erosion. For muzzle velocity ranges of 6.1 - 6.9 km/sec, the barrel erosion was reduced by a factor of 10. Even for the higher muzzle velocity range of 7.0 - 8.2 km/sec, the barrel erosion was reduced by a factor of 4. Gun erosion data from the Ames 0.5-inch, 1.0-inch, and 1.5-inch guns operated over a wide variety of launch conditions was examined and it was found that this data could be correlated using four different parameters: normalized powder charge energy, normalized hydrogen energy density, normalized pump tube volume and barrel diameter. The development of the correlation and the steps used to collapse the experimental data are presented. Over a certain parameter range in the correlation developed, the barrel erosion per shot is found to increase very rapidly. The correlation should prove useful in the selection of gun operating conditions and the design of new guns. Representative shapes of eroded gun barrels are also presented.

  19. Gun Sales. Firearm Facts.

    ERIC Educational Resources Information Center

    Duker, Laurie, Ed.

    Minimal federal regulations on firearm sales have facilitated the proliferation of guns, gun owners, and gun dealers in the United States. This fact sheet offers data on the growing number of firearm dealers, the relative ease of obtaining and keeping a license to sell guns from the Federal Bureau of Alcohol, Tobacco, and Firearms, the lack of…

  20. Current transmission and nonlinear effects in un-gated thermionic cathode RF guns

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Edelen, J. P.; Harris, J. R.

    Un-gated thermionic cathode RF guns are well known as a robust source of electrons for many accelerator applications. These sources are in principle scalable to high currents without degradation of the transverse emittance due to control grids but they are also known for being limited by back-bombardment. While back-bombardment presents a significant limitation, there is still a lack of general understanding on how emission over the whole RF period will affect the nature of the beams produced from these guns. In order to improve our understanding of how these guns can be used in general we develop analytical models thatmore » predict the transmission efficiency as a function of the design parameters, study how bunch compression and emission enhancement caused by Schottky barrier lowering affect the output current profile in the gun, and study the onset of space-charge limited effects and the resultant virtual cathode formation leading to a modulation in the output current distribution.« less

  1. Testing a GaAs cathode in SRF gun

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, E.; Kewisch, J.; Ben-Zvi, I.

    RF electron guns with a strained superlattice GaAs cathode are expected to generate polarized electron beams of higher brightness and lower emittance than do DC guns, due to their higher field gradient at the cathode's surface and lower cathode temperature. We plan to install a bulk GaAs:Cs in a SRF gun to evaluate the performance of both the gun and the cathode in this environment. The status of this project is: In our 1.3 GHz 1/2 cell SRF gun, the vacuum can be maintained at nearly 10{sup -12} Torr because of cryo-pumping at 2K. With conventional activation of bulk GaAs,more » we obtained a QE of 10% at 532 nm, with lifetime of more than 3 days in the preparation chamber and have shown that it can survive in transport from the preparation chamber to the gun. The beam line has been assembled and we are exploring the best conditions for baking the cathode under vacuum. We report here the progress of our test of the GaAs cathode in the SRF gun. Future particle accelerators, such as eRHIC and the ILC require high-brightness, high-current polarized electrons. Strained superlattice GaAs:Cs has been shown to be an efficient cathode for producing polarized electrons. Activation of GaAs with Cs,O(F) lowers the electron affinity and makes it energetically possible for all the electrons, excited into the conduction band that drift or diffuse to the emission surface, to escape into the vacuum. Presently, all operating polarized electron sources, such as the CEBAF, are DC guns. In these devices, the excellent ultra-high vacuum extends the lifetime of the cathode. However, the low field gradient on the photocathode's emission surface of the DC guns limits the beam quality. The higher accelerating gradients, possible in the RF guns, generate a far better beam. Until recently, most RF guns operated at room temperature, limiting the vacuum to {approx}10{sup -9} Torr. This destroys the GaAs's NEA surface. The SRF guns combine the excellent vacuum conditions of DC guns and the

  2. Racism, gun ownership and gun control: biased attitudes in US whites may influence policy decisions.

    PubMed

    O'Brien, Kerry; Forrest, Walter; Lynott, Dermot; Daly, Michael

    2013-01-01

    Racism is related to policies preferences and behaviors that adversely affect blacks and appear related to a fear of blacks (e.g., increased policing, death penalty). This study examined whether racism is also related to gun ownership and opposition to gun controls in US whites. The most recent data from the American National Election Study, a large representative US sample, was used to test relationships between racism, gun ownership, and opposition to gun control in US whites. Explanatory variables known to be related to gun ownership and gun control opposition (i.e., age, gender, education, income, conservatism, anti-government sentiment, southern vs. other states, political identification) were entered in logistic regression models, along with measures of racism, and the stereotype of blacks as violent. Outcome variables included; having a gun in the home, opposition to bans on handguns in the home, support for permits to carry concealed handguns. After accounting for all explanatory variables, logistic regressions found that for each 1 point increase in symbolic racism there was a 50% increase in the odds of having a gun at home. After also accounting for having a gun in the home, there was still a 28% increase in support for permits to carry concealed handguns, for each one point increase in symbolic racism. The relationship between symbolic racism and opposition to banning handguns in the home (OR1.27 CI 1.03,1.58) was reduced to non-significant after accounting for having a gun in the home (OR1.17 CI.94,1.46), which likely represents self-interest in retaining property (guns). Symbolic racism was related to having a gun in the home and opposition to gun control policies in US whites. The findings help explain US whites' paradoxical attitudes towards gun ownership and gun control. Such attitudes may adversely influence US gun control policy debates and decisions.

  3. Systems and methods for coating conduit interior surfaces utilizing a thermal spray gun with extension arm

    DOEpatents

    Moore, Karen A.; Zatorski, Raymond A.

    2005-07-12

    Systems and methods for applying a coating to an interior surface of a conduit. In one embodiment, a spray gun configured to apply a coating is attached to an extension arm which may be inserted into the bore of a pipe. The spray gun may be a thermal spray gun adapted to apply a powder coating. An evacuation system may be used to provide a volume area of reduced air pressure for drawing overspray out of the pipe interior during coating. The extension arm as well as the spray gun may be cooled to maintain a consistent temperature in the system, allowing for more consistent coating.

  4. Women and Guns. Firearm Facts.

    ERIC Educational Resources Information Center

    Duker, Laurie, Ed.

    Many gun manufacturers market guns to women claiming a gun can provide protection. Statistics provided in this fact sheet indicate gun ownership may provide a false sense of security that can be fatal, since the greatest threat to a woman comes from the people and guns within her own home. Contrary to "typical" scenarios created by advertisers,…

  5. Racism, Gun Ownership and Gun Control: Biased Attitudes in US Whites May Influence Policy Decisions

    PubMed Central

    O’Brien, Kerry; Forrest, Walter; Lynott, Dermot; Daly, Michael

    2013-01-01

    Objective Racism is related to policies preferences and behaviors that adversely affect blacks and appear related to a fear of blacks (e.g., increased policing, death penalty). This study examined whether racism is also related to gun ownership and opposition to gun controls in US whites. Method The most recent data from the American National Election Study, a large representative US sample, was used to test relationships between racism, gun ownership, and opposition to gun control in US whites. Explanatory variables known to be related to gun ownership and gun control opposition (i.e., age, gender, education, income, conservatism, anti-government sentiment, southern vs. other states, political identification) were entered in logistic regression models, along with measures of racism, and the stereotype of blacks as violent. Outcome variables included; having a gun in the home, opposition to bans on handguns in the home, support for permits to carry concealed handguns. Results After accounting for all explanatory variables, logistic regressions found that for each 1 point increase in symbolic racism there was a 50% increase in the odds of having a gun at home. After also accounting for having a gun in the home, there was still a 28% increase in support for permits to carry concealed handguns, for each one point increase in symbolic racism. The relationship between symbolic racism and opposition to banning handguns in the home (OR1.27 CI 1.03,1.58) was reduced to non-significant after accounting for having a gun in the home (OR1.17 CI.94,1.46), which likely represents self-interest in retaining property (guns). Conclusions Symbolic racism was related to having a gun in the home and opposition to gun control policies in US whites. The findings help explain US whites’ paradoxical attitudes towards gun ownership and gun control. Such attitudes may adversely influence US gun control policy debates and decisions. PMID:24204867

  6. Effects of a Gun Dealer's Change in Sales Practices on the Supply of Guns to Criminals

    PubMed Central

    Vernick, Jon S.; Bulzacchelli, Maria T.

    2006-01-01

    Licensed gun dealers are a major conduit for gun trafficking. Prior to May 1999, a single gun store sold more than half of the guns recovered from criminals in Milwaukee, WI, shortly following retail sale. On May 10, 1999, the store stopped selling small, inexpensive handguns popular with criminals, often called “Saturday night specials.” The purpose of this study was to estimate the effect of this gun store's changed sales practices on criminals' acquisition of new guns. We used an interrupted time-series design with comparisons to test for changes in the number of guns that police recovered from criminals within a year of retail sale following the gun dealer's new sales policy. The dealer's changed sales policy was associated with a 96% decrease in recently sold, small, inexpensive handguns use in crime in Milwaukee, a 73% decrease in crime guns recently sold by this dealer, and a 44% decrease in the flow of all new, trafficked guns to criminals in Milwaukee. The findings demonstrate the substantial impact that a single gun store's sales practices can have on the supply of new guns to criminals. Proposed anti-gun-trafficking efforts in other cities could benefit from targeting problem retail outlets. PMID:16937085

  7. Toward a terahertz-driven electron gun

    PubMed Central

    Huang, W. Ronny; Nanni, Emilio A.; Ravi, Koustuban; Hong, Kyung-Han; Fallahi, Arya; Wong, Liang Jie; Keathley, Phillip D.; Zapata, Luis E.; Kärtner, Franz X.

    2015-01-01

    Femtosecond electron bunches with keV energies and eV energy spread are needed by condensed matter physicists to resolve state transitions in carbon nanotubes, molecular structures, organic salts, and charge density wave materials. These semirelativistic electron sources are not only of interest for ultrafast electron diffraction, but also for electron energy-loss spectroscopy and as a seed for x-ray FELs. Thus far, the output energy spread (hence pulse duration) of ultrafast electron guns has been limited by the achievable electric field at the surface of the emitter, which is 10 MV/m for DC guns and 200 MV/m for RF guns. A single-cycle THz electron gun provides a unique opportunity to not only achieve GV/m surface electric fields but also with relatively low THz pulse energies, since a single-cycle transform-limited waveform is the most efficient way to achieve intense electric fields. Here, electron bunches of 50 fC from a flat copper photocathode are accelerated from rest to tens of eV by a microjoule THz pulse with peak electric field of 72 MV/m at 1 kHz repetition rate. We show that scaling to the readily-available GV/m THz field regime would translate to monoenergetic electron beams of ~100 keV. PMID:26486697

  8. Gun Violence, Mental Illness, And Laws That Prohibit Gun Possession: Evidence From Two Florida Counties

    PubMed Central

    Swanson, Jeffrey W.; Easter, Michele M.; Robertson, Allison G.; Swartz, Marvin S.; Alanis-Hirsch, Kelly; Moseley, Daniel; Dion, Charles; Petrila, John

    2016-01-01

    Gun violence kills about ninety people every day in the United States, a toll measured in wasted and ruined lives and with an annual economic price tag exceeding $200 billion. Some policy makers suggest that reforming mental health care systems and improving point-of-purchase background checks to keep guns from mentally disturbed people will address the problem. Epidemiological research shows that serious mental illness contributes little to the risk of interpersonal violence but is a strong factor in suicide, which accounts for most firearm fatalities. Meanwhile, the effectiveness of gun restrictions focused on mental illness remains poorly understood. This article examines gun-related suicide and violent crime in people with serious mental illnesses, and whether legal restrictions on firearm sales to people with a history of mental health adjudication are effective in preventing gun violence. Among the study population in two large Florida counties, we found that 62 percent of violent gun crime arrests and 28 percent of gun suicides involved individuals not legally permitted to have a gun at the time. Suggested policy reforms include enacting risk-based gun removal laws and prohibiting guns from people involuntarily detained in short-term psychiatric hospitalizations. PMID:27269024

  9. The Hydraulic Mechanism in the Orbital Blowout Fracture Because of a High-Pressure Air Gun Injury.

    PubMed

    Kang, Seok Joo; Chung, Eui Han

    2015-10-01

    There are 2 predominant mechanisms that are used to explain the pathogenesis of orbital blowout fracture; these include hydraulic and buckling mechanisms. Still, however, its pathophysiology remains uncertain. To date, studies in this series have been conducted using dry skulls, cadavers, or animals. But few clinical studies have been conducted to examine whether the hydraulic mechanism is involved in the occurrence of pure orbital blowout fracture. The authors experienced a case of a 52-year-old man who had a pure medial blowout fracture after sustaining an eye injury because of a high-pressure air gun. Our case suggests that surgeons should be aware of the possibility that the hydraulic mechanism might be involved in the blowout fracture in patients presenting with complications, such as limitation of eye movement, diplopia, and enophthalmos.

  10. The Experimental Study of Novel Pseudospark Hollow Cathode Plasma Electron Gun

    NASA Astrophysics Data System (ADS)

    Gu, Xiaowei; Meng, Lin; Sun, Yiqin; Yu, Xinhua

    2008-11-01

    The high-power microwave devices with plasma-filled have unique properties. One of the major problems associated with plasma-filled microwave sources is that ions from the plasma drift toward the gun regions of the tube. This bombardment is particularly dangerous for the gun, where high-energy ion impacts can damage the cathode surface and degrade its electron emission capabilities. One of the techniques investigated to mitigate this issue is to replace the material cathode with plasma cathode. Now, we study the novel electron gun (E-gun) that can be suitable for high power microwave device applications, adopting two forms of discharge channel, 1: a single hole channel, the structure can produce a solid electron beam; 2: porous holes channel, the structure can generate multiple electronic injection which is similar to the annular electron beam.

  11. Gun Violence, Mental Illness, And Laws That Prohibit Gun Possession: Evidence From Two Florida Counties.

    PubMed

    Swanson, Jeffrey W; Easter, Michele M; Robertson, Allison G; Swartz, Marvin S; Alanis-Hirsch, Kelly; Moseley, Daniel; Dion, Charles; Petrila, John

    2016-06-01

    Gun violence kills about ninety people every day in the United States, a toll measured in wasted and ruined lives and with an annual economic price tag exceeding $200 billion. Some policy makers suggest that reforming mental health care systems and improving point-of-purchase background checks to keep guns from mentally disturbed people will address the problem. Epidemiological research shows that serious mental illness contributes little to the risk of interpersonal violence but is a strong factor in suicide, which accounts for most firearm fatalities. Meanwhile, the effectiveness of gun restrictions focused on mental illness remains poorly understood. This article examines gun-related suicide and violent crime in people with serious mental illnesses, and whether legal restrictions on firearm sales to people with a history of mental health adjudication are effective in preventing gun violence. Among the study population in two large Florida counties, we found that 62 percent of violent gun crime arrests and 28 percent of gun suicides involved individuals not legally permitted to have a gun at the time. Suggested policy reforms include enacting risk-based gun removal laws and prohibiting guns from people involuntarily detained in short-term psychiatric hospitalizations. Project HOPE—The People-to-People Health Foundation, Inc.

  12. Improved DC Gun and Insulator Assembly

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Neubauer, Michael

    Many user facilities such as synchrotron radiation light sources and free electron lasers rely on DC high voltage photoguns with internal field gradients as high as 10 to 15 MV/m. These high gradients often lead to field emission which poses serious problems for the photocathode used to generate the electron beam and the ceramic insulators used to bias the photocathode at high voltage. Ceramic insulators are difficult to manufacture, require long commissioning times, and have poor reliability, in part because energetic electrons bury themselves in the ceramic causing a buildup of charge and eventual puncture, and also because large diametermore » ceramics are difficult to braze reliably. The lifetimes of photo cathodes inside high current DC guns exhibiting field emission are limited to less than a hundred hours. Reducing the surface gradients on the metals reduces the field emission, which serves to maintain the required ultrahigh vacuum condition. A novel gun design with gradients around 5 MV/m and operating at 350 kV, a major improvement over existing designs, was proposed that allows for the in-situ replacement of photo cathodes in axially symmetric designs using inverted ceramics. In this project, the existing JLAB CEBAF asymmetric gun design with an inverted ceramic support was modeled and the beam dynamics characterized. An improved structure was designed that reduces the surface gradients and improves the beam optics. To minimize the surface gradients, a number of electrostatic gun designs were studied to determine the optimum configuration of the critical electrodes within the gun structure. Coating experiments were carried out to create a charge dissipative coating for cylindrical ceramics. The phase II proposal, which was not granted, included the design and fabrication of an axially symmetric DC Gun with an inverted ceramic that would operate with less than 5 MV/m at 350 kV and would be designed with an in-situ replaceable photo-cathode.« less

  13. Large Bore Powder Gun Qualification (U)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rabern, Donald A.; Valdiviez, Robert

    A Large Bore Powder Gun (LBPG) is being designed to enable experimentalists to characterize material behavior outside the capabilities of the NNSS JASPER and LANL TA-55 PF-4 guns. The combination of these three guns will create a capability to conduct impact experiments over a wide range of pressures and shock profiles. The Large Bore Powder Gun will be fielded at the Nevada National Security Site (NNSS) U1a Complex. The Complex is nearly 1000 ft below ground with dedicated drifts for testing, instrumentation, and post-shot entombment. To ensure the reliability, safety, and performance of the LBPG, a qualification plan has beenmore » established and documented here. Requirements for the LBPG have been established and documented in WE-14-TR-0065 U A, Large Bore Powder Gun Customer Requirements. The document includes the requirements for the physics experiments, the gun and confinement systems, and operations at NNSS. A detailed description of the requirements is established in that document and is referred to and quoted throughout this document. Two Gun and Confinement Systems will be fielded. The Prototype Gun will be used primarily to characterize the gun and confinement performance and be the primary platform for qualification actions. This gun will also be used to investigate and qualify target and diagnostic modifications through the life of the program (U1a.104 Drift). An identical gun, the Physics Gun, will be fielded for confirmatory and Pu experiments (U1a.102D Drift). Both guns will be qualified for operation. The Gun and Confinement System design will be qualified through analysis, inspection, and testing using the Prototype Gun for the majority of process. The Physics Gun will be qualified through inspection and a limited number of qualification tests to ensure performance and behavior equivalent to the Prototype gun. Figure 1.1 shows the partial configuration of U1a and the locations of the Prototype and Physics Gun/Confinement Systems.« less

  14. Gun carrying by high school students in Boston, MA: does overestimation of peer gun carrying matter?

    PubMed

    Hemenway, David; Vriniotis, Mary; Johnson, Renee M; Miller, Matthew; Azrael, Deborah

    2011-10-01

    This paper investigates: (1) whether high school students overestimate gun carrying by their peers, and (2) whether those students who overestimate peer gun carrying are more likely to carry firearms. Data come from a randomly sampled survey conducted in 2008 of over 1,700 high school students in Boston, MA. Over 5% of students reported carrying a gun, 9% of boys and 2% of girls. Students substantially overestimated the percentage of their peers who carried guns; the likelihood that a respondent carried a gun was strongly associated with their perception of the level of peer gun carrying. Most respondents believed it was easier for other youth to obtain guns than it was for them. Social marketing campaigns designed to lower young people's perceptions about the prevalence of peer gun carrying may be a promising strategy for reducing actual gun carrying among youth. Copyright © 2010 The Foundation for Professionals in Services for Adolescents. Published by Elsevier Ltd. All rights reserved.

  15. Optimizing RF gun cavity geometry within an automated injector design system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Alicia Hofler ,Pavel Evtushenko

    2011-03-28

    RF guns play an integral role in the success of several light sources around the world, and properly designed and optimized cw superconducting RF (SRF) guns can provide a path to higher average brightness. As the need for these guns grows, it is important to have automated optimization software tools that vary the geometry of the gun cavity as part of the injector design process. This will allow designers to improve existing designs for present installations, extend the utility of these guns to other applications, and develop new designs. An evolutionary algorithm (EA) based system can provide this capability becausemore » EAs can search in parallel a large parameter space (often non-linear) and in a relatively short time identify promising regions of the space for more careful consideration. The injector designer can then evaluate more cavity design parameters during the injector optimization process against the beam performance requirements of the injector. This paper will describe an extension to the APISA software that allows the cavity geometry to be modified as part of the injector optimization and provide examples of its application to existing RF and SRF gun designs.« less

  16. Back-bombardment compensation in microwave thermionic electron guns

    NASA Astrophysics Data System (ADS)

    Kowalczyk, Jeremy M. D.; Madey, John M. J.

    2014-12-01

    The development of capable, reliable, and cost-effective compact electron beam sources remains a long-standing objective of the efforts to develop the accelerator systems needed for on-site research and industrial applications ranging from electron beam welding to high performance x-ray and gamma ray light sources for element-resolved microanalysis and national security. The need in these applications for simplicity, reliability, and low cost has emphasized solutions compatible with the use of the long established and commercially available pulsed microwave rf sources and L-, S- or X-band linear accelerators. Thermionic microwave electron guns have proven to be one successful approach to the development of the electron sources for these systems providing high macropulse average current beams with picosecond pulse lengths and good emittance out to macropulse lengths of 4-5 microseconds. But longer macropulse lengths are now needed for use in inverse-Compton x-ray sources and other emerging applications. We describe in this paper our approach to extending the usable macropulse current and pulse length of these guns through the use of thermal diffusion to compensate for the increase in cathode surface temperature due to back-bombardment.

  17. Goods for Guns--the use of a gun buyback as an injury prevention/community education tool.

    PubMed

    McGuire, Margaret; Manno, Mariann; Rook, Allison; Maranda, Louise; Renaud, Elizabeth; DeRoss, Anthony; Hirsh, Michael

    2011-11-01

    US children aged between 5 years and 14 years have a rate of gun-related homicide 17 times higher and a rate of gun-related suicide and unintentional firearm injury 10 times higher than other developed countries. Gun buyback programs have been criticized as ineffective interventions in decreasing violence. The Injury Free Coalition for Kids-Worcester (IFCK-W) Goods for Guns buyback is a multipronged approach to address these concerns and to reduce the number of firearms in the community. The IFCK-W buyback program is funded by corporate sponsors, grants, and individual donations. Citizens are instructed to transport guns, ammunition, and weapons safely to police headquarters on two Saturdays in December. Participants are guaranteed anonymity by the District Attorney's office and receive gift certificates for operable guns. Trained volunteers administer an anonymous survey to willing participants. Individuals who disclose having unsafely stored guns remaining at home receive educational counseling and trigger locks. Guns and ammunition are destroyed at a later time in a gun crushing ceremony. Since 2002, 1,861 guns (444 rifle/shotgun, 738 pistol/revolver, and 679 automatic/semiautomatic) have been collected at a cost of $99,250 (average, $53/gun). Seven hundred ten people have surrendered firearms, 534 surveys have been administered, and ≈ 75 trigger locks have been distributed per year. IFCK-W Goods for Guns is a relatively inexpensive injury prevention model program that removes unwanted firearms from homes, raises community awareness about gun safety, and provides high-risk individuals with trigger locks and educational counseling.

  18. The effects of pulse pressure from seismic water gun technology on Northern Pike

    USGS Publications Warehouse

    Gross, Jackson A.; Irvine, Kathryn M.; Wilmoth, Siri K.; Wagner, Tristany L.; Shields, Patrick A; Fox, Jeffrey R.

    2013-01-01

    We examined the efficacy of sound pressure pulses generated from a water gun for controlling invasive Northern Pike Esox lucius. Pulse pressures from two sizes of water guns were evaluated for their effects on individual fish placed at a predetermined random distance. Fish mortality from a 5,620.8-cm3 water gun (peak pressure source level = 252 dB referenced to 1 μP at 1 m) was assessed every 24 h for 168 h, and damage (intact, hematoma, or rupture) to the gas bladder, kidney, and liver was recorded. The experiment was replicated with a 1,966.4-cm3 water gun (peak pressure source level = 244 dB referenced to 1 μP at 1 m), but fish were euthanized immediately. The peak sound pressure level (SPLpeak), peak-to-peak sound pressure level (SPLp-p), and frequency spectrums were recorded, and the cumulative sound exposure level (SELcum) was subsequently calculated. The SPLpeak, SPLp-p, and SELcum were correlated, and values varied significantly by treatment group for both guns. Mortality increased and organ damage was greater with decreasing distance to the water gun. Mortality (31%) by 168 h was only observed for Northern Pike exhibiting the highest degree of organ damage. Mortality at 72 h and 168 h postexposure was associated with increasing SELcum above 195 dB. The minimum SELcum calculated for gas bladder rupture was 199 dB recorded at 9 m from the 5,620.8-cm3 water gun and 194 dB recorded at 6 m from the 1,966.4-cm3water gun. Among Northern Pike that were exposed to the large water gun, 100% of fish exposed at 3 and 6 m had ruptured gas bladders, and 86% exposed at 9 m had ruptured gas bladders. Among fish that were exposed to pulse pressures from the smaller water gun, 78% exhibited gas bladder rupture. Results from these initial controlled experiments underscore the potential of water guns as a tool for controlling Northern Pike.

  19. Simplified pipe gun

    NASA Astrophysics Data System (ADS)

    Sørensen, H.; Nordskov, A.; Sass, B.; Visler, T.

    1987-12-01

    A simplified version of a deuterium pellet gun based on the pipe gun principle is described. The pipe gun is made from a continuous tube of stainless steel and gas is fed in from the muzzle end only. It is indicated that the pellet length is determined by the temperature gradient along the barrel right outside the freezing cell. Velocities of around 1000 m/s with a scatter of ±2% are obtained with a propellant gas pressure of 40 bar.

  20. Gun Attitudes and Fear of Crime.

    ERIC Educational Resources Information Center

    Heath, Linda; Weeks, Kyle; Murphy, Marie Mackay

    1997-01-01

    Using three studies, examined the relationship between attitudes toward guns and fear of crime. Findings indicate a connection between fear of crime and attitudes toward guns: people higher in fear of crime favored gun control. Results also established a relationship between stereotypical beliefs about gun victims and support for gun control. (RJM)

  1. Numerical modelling of the CEBAF electron gun with EGUN

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Philippe Liger; Geoffrey Krafft

    1990-09-10

    The electron source used in the injector for the CEBAF accelerator is a Hermosa electron gun with a 2 mm diameter cathode and a control electrode. It produces a 100 keV electron beam to be focused on the first of two apertures which comprise an emittance filter. A normalized emittance of less than {pi} mm mrad at 1.2 mA is set by the requirements of the final beam from the CEBAF linac, since downstream of the filter, a system of two choppers and a third aperture removes 5/6 of the current. In addition, for RF test purposes a higher currentmore » of about 5 mA is needed, possibly at higher emittance. This paper presents a way of calculating the characteristics of the CEBAF electron gun with the gun design code EGUN, and the accuracy of the results is discussed. The transverse shape of the beam delivered by the gun has been observed, and its current measured. A halo around the beam has been seen, and the calculations can reproduce this effect.« less

  2. Guns and High Gas Output Devices Panel: Introduction

    NASA Technical Reports Server (NTRS)

    Simmons, Ronald L.; Kaste, Pamela J.

    2000-01-01

    A new panel known as the Guns and High Gas Output Panel was organized in 1999 under the auspices of the JANNAF Propellant and Characterization SubCommittee (PDCS). This is an introduction to our first meeting, purpose of the panel, and the scope of activities to be covered. The primary purpose of the panel is very simple: to provide a single focal point for interfacing Government Laboratories (Department of Defense and Department of Energy) and commercial industry researchers to share R&D activities and findings (i.e. facilitate the exchange of information) specifically aimed at gun-launched propulsion and high-gas output devices (gas generators and air bag inflators). Specific areas of interest included in the Panel's scope (and the Technical Data Base) are the following: (1) new propellant formulations and chemistry, (2) new ingredients, (3) ballistic effects of the new formulations and ingredients, (4) new processing methods unique to gun propellants, (5) thermochemistry of new ingredients, (6) unique physical and mechanical properties, (7) burning rates of new propellants and small scale closed bomb testing, (8) plasma effects on the propellant, and (9) unique safety and insensitive munitions properties.

  3. One-in-a-million shot: a homicidal thoracic air rifle wound, a case report, and a review of the literature.

    PubMed

    Bligh-Glover, William Z

    2012-03-01

    A homicidal shooting with an air gun is reported. The history, mechanisms of action, and crime scene implications of air guns are discussed. The wounds produced by air guns are compared to those produced by powder firearms.

  4. The case for moderate gun control.

    PubMed

    DeGrazia, David

    2014-03-01

    In addressing the shape of appropriate gun policy, this essay assumes for the sake of discussion that there is a legal and moral right to private gun ownership. My thesis is that, against the background of this right, the most defensible policy approach in the United States would feature moderate gun control. The first section summarizes the American gun control status quo and characterizes what I call "moderate gun control." The next section states and rebuts six leading arguments against this general approach to gun policy. The section that follows presents a positive case for moderate gun control that emphasizes safety in the home and society as well as rights whose enforcement entails some limits or qualifications on the right to bear arms. A final section shows how the recommended gun regulations address legitimate purposes, rather than imposing arbitrary restrictions on gun rights, and offers concluding reflections.

  5. Compact streak camera for the shock study of solids by using the high-pressure gas gun

    NASA Astrophysics Data System (ADS)

    Nagayama, Kunihito; Mori, Yasuhito

    1993-01-01

    For the precise observation of high-speed impact phenomena, a compact high-speed streak camera recording system has been developed. The system consists of a high-pressure gas gun, a streak camera, and a long-pulse dye laser. The gas gun installed in our laboratory has a muzzle of 40 mm in diameter, and a launch tube of 2 m long. Projectile velocity is measured by the laser beam cut method. The gun is capable of accelerating a 27 g projectile up to 500 m/s, if helium gas is used as a driver. The system has been designed on the principal idea that the precise optical measurement methods developed in other areas of research can be applied to the gun study. The streak camera is 300 mm in diameter, with a rectangular rotating mirror which is driven by an air turbine spindle. The attainable streak velocity is 3 mm/microsecond(s) . The size of the camera is rather small aiming at the portability and economy. Therefore, the streak velocity is relatively slower than the fast cameras, but it is possible to use low-sensitivity but high-resolution film as a recording medium. We have also constructed a pulsed dye laser of 25 - 30 microsecond(s) in duration. The laser can be used as a light source of observation. The advantage for the use of the laser will be multi-fold, i.e., good directivity, almost single frequency, and so on. The feasibility of the system has been demonstrated by performing several experiments.

  6. Environment and air pollution like gun and bullet for low-income countries: war for better health and wealth.

    PubMed

    Zou, Xiang; Azam, Muhammad; Islam, Talat; Zaman, Khalid

    2016-02-01

    The objective of the study is to examine the impact of environmental indicators and air pollution on "health" and "wealth" for the low-income countries. The study used a number of promising variables including arable land, fossil fuel energy consumption, population density, and carbon dioxide emissions that simultaneously affect the health (i.e., health expenditures per capita) and wealth (i.e., GDP per capita) of the low-income countries. The general representation for low-income countries has shown by aggregate data that consist of 39 observations from the period of 1975-2013. The study decomposes the data set from different econometric tests for managing robust inferences. The study uses temporal forecasting for the health and wealth model by a vector error correction model (VECM) and an innovation accounting technique. The results show that environment and air pollution is the menace for low-income countries' health and wealth. Among environmental indicators, arable land has the largest variance to affect health and wealth for the next 10-year period, while air pollution exerts the least contribution to change health and wealth of low-income countries. These results indicate the prevalence of war situation, where environment and air pollution become visible like "gun" and "bullet" for low-income countries. There are required sound and effective macroeconomic policies to combat with the environmental evils that affect the health and wealth of the low-income countries.

  7. [The chemical action of gun powder gases on biological tissues in a point-blank shot].

    PubMed

    Popov, V L; Isakov, V D; Babakhanian, R V; Karnasevich, Iu A

    1992-01-01

    Chemical effect of gun powder gas on the biologic tissues manifests by red-brown staining of the tissues, mainly at the expense of methemoglobin and sulfhemoglobin. Scarlet staining of the tissues at the edges of gun-shot wounds is not a specific marker of a shot made from a short distance; it may emerge several hours after wounding at the expense of hydroxy-hemoglobin and is not at all related to the chemical effect of gun powder gas. The conditions conducive to scarlet staining are an open wound permitting free oxygenation by air oxygen and hemoglobin transfer from the injured red cells into blood plasma and adjacent tissues.

  8. Long-Life/Low-Power Ion-Gun Cathode

    NASA Technical Reports Server (NTRS)

    Fitzgerald, D. J.

    1982-01-01

    New cathode has form of hollow tube through which gas enters region of high electron density, produced by electric discharge with auxiliary electrode referred to as "keeper." Ion-gun cathode emits electrons that bombard gas in chamber. Ions accelerated out of source are used to dope semiconductor material.

  9. RF study and 3-D simulations of a side-coupling thermionic RF-gun

    NASA Astrophysics Data System (ADS)

    Rimjaem, S.; Kusoljariyakul, K.; Thongbai, C.

    2014-02-01

    A thermionic RF-gun for generating ultra-short electron bunches was optimized, developed and used as a source at a linac-based THz radiation research laboratory of the Plasma and Beam Physics Research Facility, Chiang Mai University, Thailand. The RF-gun is a π/2-mode standing wave structure, which consists of two S-band accelerating cells and a side-coupling cavity. The 2856 MHz RF wave is supplied from an S-band klystron to the gun through the waveguide input-port at the cylindrical wall of the second cell. A fraction of the RF power is coupled from the second cell to the first one via a side-coupling cavity. Both the waveguide input-port and the side-coupling cavity lead to an asymmetric geometry of the gun. RF properties and electromagnetic field distributions inside the RF-gun were studied and numerically simulated by using computer codes SUPERFISH 7.19 and CST Microwave Studio 2012©. RF characterizations and tunings of the RF-gun were performed to ensure the reliability of the gun operation. The results from 3D simulations and measurements are compared and discussed in this paper. The influence of asymmetric field distributions inside the RF-gun on the electron beam properties was investigated via 3D beam dynamics simulations. A change in the coupling-plane of the side-coupling cavity is suggested to improve the gun performance.

  10. Commissioning Results of the 2nd 3.5 Cell SRF Gun for ELBE

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Arnold, A; Freitag, M; Murcek, Petr

    As in 2007 the first 3.5 cell superconducting radio frequency (SRF) gun was taken into operation, it turned out that the specified performance has not been achieved. However, to demonstrate the full potential of this new type of electron source, a second and slightly modified SRF gun II was built in collaboration with Thomas Jefferson National Accelerator Facility (TJNAF). We will report on commissioning and first results of the new gun, which includes in particular the characterization of the most important RF properties as well as their comparison with previous vertical test results.

  11. NASA Researcher with a Coaxial Plasma Gun

    NASA Image and Video Library

    1962-06-21

    Researcher Charles Michels operates a coaxial plasma gun rig in Cell SW-13 of the Engine Research Building at the National Aeronautics and Space Administration (NASA) Lewis Research Center. From 1962 to 1967 NASA Lewis investigated coaxial plasma guns powered by conventional capacitor banks. The studies were part of a larger effort to identify electromagnetic accelerators for space propulsion. NASA worked with General Dynamics, General Electric, General Motors, and Republic Aviation on the project. NASA Lewis conducted a research program to determine which factors influenced the coaxial gun’s efficiency and analyze the acceleration process. The system had not previously been used for propulsion applications. The single-shot gun’s fast gas valve and capacitor banks with variable-delay ignition source permitted the evaluation of gun performance under controllable propellant quantity and distribution conditions. The coaxial plasma gun was the most basic type of electromagnetic accelerator. It included a charged capacitor in series with a pair of coaxial electrodes. An electrical breakdown occurred when gas was admitted to the inter-electrode region. The gas instantly became a good conductor and formed a conducting sheet that separated the magnetic field from the open region beyond. The highly-conducting gas was basically expelled by the force of the magnetic pressure. This type of thruster could operate at the high instantaneous power levels without decreasing its average power level.

  12. Unbalanced field RF electron gun

    DOEpatents

    Hofler, Alicia

    2013-11-12

    A design for an RF electron gun having a gun cavity utilizing an unbalanced electric field arrangement. Essentially, the electric field in the first (partial) cell has higher field strength than the electric field in the second (full) cell of the electron gun. The accompanying method discloses the use of the unbalanced field arrangement in the operation of an RF electron gun in order to accelerate an electron beam.

  13. Note: O-ring stack system for electron gun alignment.

    PubMed

    Park, In-Yong; Cho, Boklae; Han, Cheolsu; Shin, Seungmin; Lee, Dongjun; Ahn, Sang Jung

    2015-01-01

    We present a reliable method for aligning an electron gun which consists of an electron source and lenses by controlling a stack of rubber O-rings in a vacuum condition. The beam direction angle is precisely tilted along two axes by adjusting the height difference of a stack of O-rings. In addition, the source position is shifted in each of three orthogonal directions. We show that the tilting angle and linear shift along the x and y axes as obtained from ten stacked O-rings are ±2.55° and ±2 mm, respectively. This study can easily be adapted to charged particle gun alignment and adjustments of the flange position in a vacuum, ensuring that its results can be useful with regard to electrical insulation between flanges with slight modifications.

  14. An ultrafast nanotip electron gun triggered by grating-coupled surface plasmons

    NASA Astrophysics Data System (ADS)

    Schröder, Benjamin; Sivis, Murat; Bormann, Reiner; Schäfer, Sascha; Ropers, Claus

    2015-12-01

    We demonstrate multiphoton photoelectron emission from gold nanotips induced by nanofocusing surface plasmons, resonantly excited on the tip shaft by a grating coupler. The tip is integrated into an electron gun assembly, which facilitates control over the spatial emission sites and allows us to disentangle direct grating emission from plasmon-triggered apex emission. The nanoscale source size of this electron gun concept enables highly coherent electron pulses with applications in ultrafast electron imaging and diffraction.

  15. An ultrafast nanotip electron gun triggered by grating-coupled surface plasmons

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schröder, Benjamin; Sivis, Murat; Bormann, Reiner

    We demonstrate multiphoton photoelectron emission from gold nanotips induced by nanofocusing surface plasmons, resonantly excited on the tip shaft by a grating coupler. The tip is integrated into an electron gun assembly, which facilitates control over the spatial emission sites and allows us to disentangle direct grating emission from plasmon-triggered apex emission. The nanoscale source size of this electron gun concept enables highly coherent electron pulses with applications in ultrafast electron imaging and diffraction.

  16. From gun politics to self-defense politics: a feminist critique of the great gun debate.

    PubMed

    Carlson, Jennifer D

    2014-03-01

    This article calls attention to a problematic binary produced by public debates surrounding gun rights and gun control-namely, that women must choose armed self-protection or no self-protection at all. I argue that both anti- and pro-gun discourses, drawing on and reproducing race and class privileges, use assumptions about women's physical inferiority to further their agendas. I highlight how both sides have used guns as the proxy for self-defense and conclude by calling for a shift in public discourse to focus on the broader question of the right to self-defense rather than the narrower question of gun rights.

  17. RF Design of the LCLS Gun

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Limborg-Deprey, C

    Final dimensions for the LCLS RF gun are described. This gun, referred to as the LCLS gun, is a modified version of the UCLA/BNL/SLAC 1.6 cell S-Band RF gun [1], referred to as the prototype gun. The changes include a larger mode separation (15 MHz for the LCLS gun vs. 3.5 MHz for the prototype gun), a larger radius at the iris between the 2 cells, a reduced surface field on the curvature of the iris between the two cells, Z power coupling, increased cooling channels for operation at 120 Hz, dual rf feed, deformation tuning of the full cell,more » and field probes in both cells. Temporal shaping of the klystron pulse, to reduce the average power dissipated in the gun, has also been adopted. By increasing the mode separation, the amplitude of the 0-mode electric field on the cathode decreases from 10% of the peak on axis field for the prototype gun to less than 3% for the LCLS gun for the steady state fields. Beam performance is improved as shown by the PARMELA simulations. The gun should be designed to accept a future load lock system. Modifications follow the recommendations of our RF review committee [2]. Files and reference documents are compiled in Section IV.« less

  18. Initial Beam Dynamics Simulations of a High-Average-Current Field-Emission Electron Source in a Superconducting RadioFrequency Gun

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mohsen, O.; Gonin, I.; Kephart, R.

    High-power electron beams are sought-after tools in support to a wide array of societal applications. This paper investigates the production of high-power electron beams by combining a high-current field-emission electron source to a superconducting radio-frequency (SRF) cavity. We especially carry out beam-dynamics simulations that demonstrate the viability of the scheme to formmore » $$\\sim$$ 300 kW average-power electron beam using a 1+1/2-cell SRF gun.« less

  19. The life cycle of crime guns: a description based on guns recovered from young people in California.

    PubMed

    Wintemute, Garen J; Romero, Michael P; Wright, Mona A; Grassel, Kevin M

    2004-06-01

    We describe the life cycle of crime guns recovered from young people-the movement of those guns from manufacture to criminal use-and identify associations between the characteristics of those guns and their possessors, purchasers, sellers, and places of origin. This is a cross-sectional study of data from gun ownership tracing records compiled by the Bureau of Alcohol, Tobacco, Firearms and Explosives for 2,121 crime guns recovered in California from persons younger than 25 years and traced in 1999. Purchaser and seller data for handguns were updated when possible by linking to California handgun sales records. The 2,121 traced guns were recovered from 1,717 young people. Guns recovered from persons aged 21 to 24 years were most frequently also purchased by persons aged 21 to 24 years; those recovered from persons younger than 18 years were most often purchased by persons aged 45 years or older. Small-caliber handguns made up 41.0% of handguns recovered from persons younger than 18 years but 25.2% of handguns recovered from persons aged 21 to 24 years. The median time from sale to recovery (commonly called time to crime) for all guns was 6.4 years (interquartile range 2.7 to 12.4 years). A time to crime of less than 3 years, suggesting deliberate gun trafficking, was observed for 17.3% of guns recovered from persons younger than 18 years but 34.6% of guns recovered from persons aged 21 to 24 years. Ten retailers who sold 10 or more traced guns accounted for 13.1% of all guns traced to a retailer. Handguns whose purchaser and possessor were the same person were more likely than others to be large-caliber semiautomatic pistols (29.3% and 11.7%, respectively); their median time to crime was 0.2 years (69 days). Analysis of crime-gun ownership traces reveals patterns that may help refine gun violence prevention efforts and render them more effective.

  20. A Computer Study of Air Defense Gun Effectiveness.

    DTIC Science & Technology

    1987-12-01

    A7 4 m410 pP 43 ’RANGE=1 C44 5 0 4 10 pR [45 C+( (DAJA+1),(PRANGES))PRANGES L46 Cl 4-(C) V GUN;I VAC;BODY;TOP:SIDE; VRX ;VRY; VRZE1 o...2 10 pP 4 5 A IRANGE=’ 146 n 50 10 pOR4e7 DAA+(DATA+I),-(RANlES))pRANGES 48 C+,(RC) VGUN;I;VAC,.BODY-,TOP;SIDE*. VRX -,VRY;VRZ ?- 2 ****’HA SIMULATES...AXYx (loOl ) [36] VRZ+l NORRAND VZ1 [37] VRX *-1 NORRAN VX ~ v [38] VRY-1 NORRAN VY l~v V INTERCEPT;F1TN;-BURSTIME;-XF1;:YF1 ;ZF1 ;RPROJ;N;FTN 2

  1. Development of a low-energy and high-current pulsed neutral beam injector with a washer-gun plasma source for high-beta plasma experiments.

    PubMed

    Ii, Toru; Gi, Keii; Umezawa, Toshiyuki; Asai, Tomohiko; Inomoto, Michiaki; Ono, Yasushi

    2012-08-01

    We have developed a novel and economical neutral-beam injection system by employing a washer-gun plasma source. It provides a low-cost and maintenance-free ion beam, thus eliminating the need for the filaments and water-cooling systems employed conventionally. In our primary experiments, the washer gun produced a source plasma with an electron temperature of approximately 5 eV and an electron density of 5 × 10(17) m(-3), i.e., conditions suitable for ion-beam extraction. The dependence of the extracted beam current on the acceleration voltage is consistent with space-charge current limitation, because the observed current density is almost proportional to the 3/2 power of the acceleration voltage below approximately 8 kV. By optimizing plasma formation, we successfully achieved beam extraction of up to 40 A at 15 kV and a pulse length in excess of 0.25 ms. Its low-voltage and high-current pulsed-beam properties enable us to apply this high-power neutral beam injection into a high-beta compact torus plasma characterized by a low magnetic field.

  2. 77 FR 37834 - Revocation of Certain Requirements Pertaining to Caps Intended for Use With Toy Guns and Toy Guns...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-06-25

    ... Certain Requirements Pertaining to Caps Intended for Use With Toy Guns and Toy Guns Not Intended for Use... compliance than our existing regulations pertaining to caps intended for use with toy guns and toy guns not... regulations pertaining to caps intended for use with toy guns and toy guns not intended for use with caps...

  3. Magnetron Electron Gun,

    DTIC Science & Technology

    1980-05-23

    ULMAGNETRON ELECTRON GUN . (U) .Ay G0 A L GOLOENBERG, T B PANKRATOVA UNCLASSIFIED FTD..In(RS)T41896-?9 4 __ ihD - -111113 MICROCOPY RESOLUTION TEST...CHART NATIONAL BUREAU OF STANDARD 1961 A -_"D-I-D ,RS)T-18q6-79 v FOREIGN TECHNOLOGY DIVISION MAGNETRON ELECTRON GUN by A. L. Gol’denberg, T. B...VISION. WP.AP6. OHIO. FTD -ID(RS)T-1396-79 Date z.-.:a’,-lq -,o • 110ewm /A Is a, -D r.l MAGNETRON ELECTRON GUN A. L. Gol’denberg, T. B. Pankratova and M

  4. Effects of undercover police stings of gun dealers on the supply of new guns to criminals

    PubMed Central

    Webster, D W; Bulzacchelli, M T; Zeoli, A M; Vernick, J S

    2006-01-01

    Objective To assess the effects of undercover police stings and lawsuits against gun dealers suspected of facilitating illegal gun sales in three US cities (Chicago, Detroit, Gary) on the flow of new firearms to criminals. Methods An interrupted time series design and negative binomial regression analyses were used to test for temporal change in the recovery of guns used in crimes within one year of retail sale in both intervention and comparison cities. Results The stings were associated with an abrupt 46.4% reduction in the flow of new guns to criminals in Chicago (95% confidence interval, −58.6% to −30.5%), and with a gradual reduction in new crime guns recovered in Detroit. There was no significant change associated with the stings in Gary, and no change in comparison cities that was coincident with the stings in Chicago and Detroit. Conclusions The announcement of police stings and lawsuits against suspect gun dealers appeared to have reduced the supply of new guns to criminals in Chicago significantly, and may have contributed to beneficial effects in Detroit. Given the important role that gun stores play in supplying guns to criminals in the US, further efforts of this type are warranted and should be evaluated. PMID:16887943

  5. Keeping Naval Guns Ready

    DTIC Science & Technology

    2016-03-01

    Keeping Naval Guns Ready David L. Rogers Rogers is the Deputy Department Head, Systems Integration Department, Naval Surface Warfare Center Indian...maritime routes and the global economy. This protection depends on keeping these forward naval ships ready, par- ticularly their guns and ammunition...the weapons of choice for counter- ing a multitude of threats. That gun readiness is assured with responsive technical support. It is done fast, and

  6. Loaded: Gun involvement among opioid users.

    PubMed

    Stein, Michael D; Kenney, Shannon R; Anderson, Bradley J; Bailey, Genie L

    2018-06-01

    Despite ample research examining how alcohol use relates to gun involvement, little is known about the relationship between opioids and gun involvement. In the current study, we examined correlates of gun possession, accessibility, and related behaviors in an opioid dependent sample. Between October 2016 and April 2017, we surveyed persons entering a brief, inpatient opioid detoxification (n = 386) and 51 contemporaneous persons seeking alcohol detoxification at the same facility in Massachusetts and recorded their lifetime experiences with gun involvement. Participants averaged 33 years of age, 74% were male, 83% were White, and 64% had a history of incarceration. Opioid users had significantly higher rates of gun involvement than persons in alcohol detoxification; for example, 31.3% (vs. 3.9%) had carried a gun for protection, 45.1% (vs. 25.5%) had been threatened with a gun, and 13.8% (vs. 2.0%) had shot at another person. Among persons misusing opioids, male and non-White respondents, and those with a history of incarceration or poorer self-control reported greater gun involvement. Opioid users, both men and women, lead gun-involved lives. Copyright © 2018 Elsevier B.V. All rights reserved.

  7. Air gun wounding and current UK laws controlling air weapons.

    PubMed

    Bruce-Chwatt, Robert Michael

    2010-04-01

    Air weapons whether rifles or pistols are, potentially, lethal weapons. The UK legislation is complex and yet little known to the public. Hunting with air weapons and the laws controlling those animals that are permitted to be shot with air weapons is even more labyrinthine due to the legal power limitations on the possession of air weapons. Still relatively freely available by mail order or on the Internet, an increasing number of deaths have been reported from the misuse of air weapons or accidental discharges. Ammunition for air weapons has become increasingly sophisticated, effective and therefore increasingly dangerous if misused, though freely available being a mere projectile without a concomitant cartridge containing a propellant and an initiator.

  8. Revisiting Pneumatic Nail Gun Trigger Recommendations

    PubMed Central

    Albers, James; Lipscomb, Hester; Hudock, Stephen; Dement, John; Evanoff, Bradley; Fullen, Mark; Gillen, Matt; Kaskutas, Vicki; Nolan, James; Patterson, Dennis; Platner, James; Pompeii, Lisa; Schoenfisch, Ashley

    2015-01-01

    Summary Use of a pneumatic nail gun with a sequential actuation trigger (SAT) significantly diminishes the risk for acute traumatic injury compared to use of a contact actuation trigger (CAT) nail gun. A theoretically-based increased risk of work-related musculoskeletal disorders from use of a SAT nail gun, relative to CAT, appears unlikely and remains unproven. Based on current knowledge, the use of CAT nail guns cannot be justified as a safe alternative to SAT nail guns. This letter provides a perspective of ergonomists and occupational safety researchers recommending the use of the sequential actuation trigger for all nail gun tasks in the construction industry. PMID:26366020

  9. Revisiting Pneumatic Nail Gun Trigger Recommendations.

    PubMed

    Albers, James; Lowe, Brian; Lipscomb, Hester; Hudock, Stephen; Dement, John; Evanoff, Bradley; Fullen, Mark; Gillen, Matt; Kaskutas, Vicki; Nolan, James; Patterson, Dennis; Platner, James; Pompeii, Lisa; Schoenfisch, Ashley

    2015-03-01

    Use of a pneumatic nail gun with a sequential actuation trigger (SAT) significantly diminishes the risk for acute traumatic injury compared to use of a contact actuation trigger (CAT) nail gun. A theoretically-based increased risk of work-related musculoskeletal disorders from use of a SAT nail gun, relative to CAT, appears unlikely and remains unproven. Based on current knowledge, the use of CAT nail guns cannot be justified as a safe alternative to SAT nail guns. This letter provides a perspective of ergonomists and occupational safety researchers recommending the use of the sequential actuation trigger for all nail gun tasks in the construction industry.

  10. Children, Youth, and Gun Violence.

    ERIC Educational Resources Information Center

    Behrman, Richard E., Ed.

    2002-01-01

    This collection of articles summarizes knowledge and research about how gun violence affects children and youth and discusses which policies hold promise for reducing youth gun violence. The papers are: (1) "Statement of Purpose" (Richard E. Behrman); "Children, Youth, and Gun Violence: Analysis and Recommendations" (Kathleen…

  11. Note: O-ring stack system for electron gun alignment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Park, In-Yong; Cho, Boklae; Han, Cheolsu

    We present a reliable method for aligning an electron gun which consists of an electron source and lenses by controlling a stack of rubber O-rings in a vacuum condition. The beam direction angle is precisely tilted along two axes by adjusting the height difference of a stack of O-rings. In addition, the source position is shifted in each of three orthogonal directions. We show that the tilting angle and linear shift along the x and y axes as obtained from ten stacked O-rings are ±2.55° and ±2 mm, respectively. This study can easily be adapted to charged particle gun alignmentmore » and adjustments of the flange position in a vacuum, ensuring that its results can be useful with regard to electrical insulation between flanges with slight modifications.« less

  12. Experimental evaluation of a mathematical model for predicting transfer efficiency of a high volume-low pressure air spray gun.

    PubMed

    Tan, Y M; Flynn, M R

    2000-10-01

    The transfer efficiency of a spray-painting gun is defined as the amount of coating applied to the workpiece divided by the amount sprayed. Characterizing this transfer process allows for accurate estimation of the overspray generation rate, which is important for determining a spray painter's exposure to airborne contaminants. This study presents an experimental evaluation of a mathematical model for predicting the transfer efficiency of a high volume-low pressure spray gun. The effects of gun-to-surface distance and nozzle pressure on the agreement between the transfer efficiency measurement and prediction were examined. Wind tunnel studies and non-volatile vacuum pump oil in place of commercial paint were used to determine transfer efficiency at nine gun-to-surface distances and four nozzle pressure levels. The mathematical model successfully predicts transfer efficiency within the uncertainty limits. The least squares regression between measured and predicted transfer efficiency has a slope of 0.83 and an intercept of 0.12 (R2 = 0.98). Two correction factors were determined to improve the mathematical model. At higher nozzle pressure settings, 6.5 psig and 5.5 psig, the correction factor is a function of both gun-to-surface distance and nozzle pressure level. At lower nozzle pressures, 4 psig and 2.75 psig, gun-to-surface distance slightly influences the correction factor, while nozzle pressure has no discernible effect.

  13. Preventing gun injuries in children.

    PubMed

    Crossen, Eric J; Lewis, Brenna; Hoffman, Benjamin D

    2015-02-01

    Firearms are involved in the injury and death of a large number of children each year from both intentional and unintentional causes. Gun ownership in homes with children is common, and pediatricians should incorporate evidence-based means to discuss firearms and protect children from gun-related injuries and violence. Safe storage of guns, including unloaded guns locked and stored separately from ammunition, can decrease risks to children, and effective tools are available that pediatricians can use in clinical settings to help decrease children's access to firearms. Furthermore, several community-based interventions led by pediatricians have effectively reduced firearm-related injury risks to children. Educational programs that focus on children's behavior around guns have not proven effective. © American Academy of Pediatrics, 2015. All rights reserved.

  14. Integrated numerical modeling of a laser gun injector

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liu, H.; Benson, S.; Bisognano, J.

    1993-06-01

    CEBAF is planning to incorporate a laser gun injector into the linac front end as a high-charge cw source for a high-power free electron laser and nuclear physics. This injector consists of a DC laser gun, a buncher, a cryounit and a chicane. The performance of the injector is predicted based on integrated numerical modeling using POISSON, SUPERFISH and PARMELA. The point-by-point method incorporated into PARMELA by McDonald is chosen for space charge treatment. The concept of ``conditioning for final bunching`` is employed to vary several crucial parameters of the system for achieving highest peak current while maintaining low emittancemore » and low energy spread. Extensive parameter variation studies show that the design will perform beyond the specifications for FEL operations aimed at industrial applications and fundamental scientific research. The calculation also shows that the injector will perform as an extremely bright cw electron source.« less

  15. BEAM DYNAMICS SIMULATIONS FOR A DC GUN BASED INJECTOR FOR PERL.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    ZHOU,F.; BEN-ZVI,I.; WANG,X.J.

    2001-06-18

    The National Synchrotron Light Source (NSLS) at Brookhaven National Laboratory (BNL) is considering an upgrade based on the Photoinjected Energy Recovering Linac (PERL). The various injector schemes for this machine are being extensively investigated at BNL. One of the possible options is photocathode DC gun. The schematic layout of a PERL DC gun based injector and its preliminary beam dynamics are presented in this paper. The transverse and longitudinal emittance of photo-electron beam were optimized for a DC field 500 kV.

  16. A gasdynamic gun driven by gaseous detonation

    NASA Astrophysics Data System (ADS)

    Li, Jinping; Chen, Hong; Zhang, Shizhong; Zhang, Xiaoyuan; Yu, Hongru

    2016-01-01

    A gasdynamic gun driven by gaseous detonation was developed to address the disadvantages of the insufficient driving capability of high-pressure gas and the constraints of gunpowder. The performance of this gasdynamic gun was investigated through experiments and numerical simulations. Much more powerful launching capability was achieved by this gun relative to a conventional high-pressure gas gun, owing to the use of the chemical energy of the driver gas. To achieve the same launching condition, the initial pressure required for this gun was an order of magnitude lower than that for a gun driven by high-pressure H2. Because of the presence of the detonation, however, a more complex internal ballistic process of this gun was observed. Acceleration of projectiles for this gun was accompanied by a series of impulse loads, in contrast with the smooth acceleration for a conventional one, which indicates that this gun should be used conditionally. The practical feasibility of this gun was verified by experiments. The experiments demonstrated the convenience of taking advantage of the techniques developed for detonation-driven shock tubes and tunnels.

  17. Guns at College.

    ERIC Educational Resources Information Center

    Miller, Matthew; Hemenway, David; Wechsler, Henry

    1999-01-01

    Surveyed undergraduate students nationwide concerning firearm possession. About 3.5% possessed working firearms. Students with guns were more likely to be male, White, or Native American; binge drink; live off-campus; and live with a spouse or significant other. Students with guns were more likely to engage in activities that put themselves and…

  18. 78 FR 66840 - Revocation of Certain Requirements Pertaining to Caps Intended for Use With Toy Guns and Toy Guns...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-11-07

    ... Certain Requirements Pertaining to Caps Intended for Use With Toy Guns and Toy Guns Not Intended for Use... regulations pertaining to caps intended for use with toy guns refer to obsolete equipment, but the ASTM F963... revokes the existing regulations pertaining to caps intended for use with toy guns and toy guns not...

  19. Vacuum vapor deposition gun assembly

    DOEpatents

    Zeren, Joseph D.

    1985-01-01

    A vapor deposition gun assembly includes a hollow body having a cylindrical outer surface and an end plate for holding an adjustable heat sink, a hot hollow cathode gun, two magnets for steering the plasma from the gun into a crucible on the heat sink, and a shutter for selectively covering and uncovering the crucible.

  20. Teen Suicide and Guns

    MedlinePlus

    ... Text Size Email Print Share Teen Suicide and Guns Page Content Article Body Protect Your Teenager Many ... American teenagers commit suicide every day. Does a gun in the home increase the chance of suicide? ...

  1. Automatic targeting of plasma spray gun

    DOEpatents

    Abbatiello, Leonard A.; Neal, Richard E.

    1978-01-01

    A means for monitoring the material portion in the flame of a plasma spray gun during spraying operations is provided. A collimated detector, sensitive to certain wavelengths of light emission, is used to locate the centroid of the material with each pass of the gun. The response from the detector is then relayed to the gun controller to be used to automatically realign the gun.

  2. Hot hollow cathode gun assembly

    DOEpatents

    Zeren, J.D.

    1983-11-22

    A hot hollow cathode deposition gun assembly includes a hollow body having a cylindrical outer surface and an end plate for holding an adjustable heat sink, the hot hollow cathode gun, two magnets for steering the plasma from the gun into a crucible on the heat sink, and a shutter for selectively covering and uncovering the crucible.

  3. Are "goods for guns" good for the community? An update of a community gun buyback program.

    PubMed

    Green, Jonathan; Damle, Rachelle N; Kasper, Rebecca E; Violano, Pina; Manno, Mariann; Nazarey, Pradeep P; Aidlen, Jeremy T; Hirsh, Michael P

    2017-08-01

    Gun violence remains a leading cause of death in the United States. Community gun buyback programs provide an opportunity to dispose of extraneous firearms. The purpose of this study was to understand the demographics, motivation, child access to firearms, and household mental illness of buyback participants in hopes of improving the program's effectiveness. A 2015 Injury Free Coalition for Kids gun buyback program which collaborated with local police departments was studied. We administered a 23-item questionnaire survey to gun buyback participants assessing demographic characteristics, motivation for relinquishing firearms, child firearm accessibility, and mental illness/domestic violence history. A total of 186 individuals from Central/Western Massachusetts turned in 339 weapons. Participants received between US $25 and US $75 in gift cards dependent on what type of gun was turned in, with an average cost of $41/gun. A total of 109 (59%) participants completed the survey. Respondents were mostly white (99%), men (90%) and first-time participants in the program (85.2%). Among survey respondents, 54% turned in firearms "for safety reasons." Respondents reported no longer needing/wanting their weapons (47%) and approximately one in eight participants were concerned the firearm(s) were accessible to children. Most respondents (87%) felt the program encouraged neighborhood awareness of firearm safety. Three of every five participants reported that guns still remained in their homes; additionally, 21% where children could potentially access them and 14% with a history of mental illness/suicide/domestic violence in the home. Gun buybacks can provide a low-cost means of removing unwanted firearms from the community. Most participants felt their homes were safer after turning in the firearm(s). In homes still possessing guns, emphasis on secure gun storage should continue, increasing the safety of children and families. The results of this survey also provided new

  4. Development program on a Spindt cold-cathode electron gun

    NASA Technical Reports Server (NTRS)

    Spindt, C. A.

    1982-01-01

    A thin film field emission cathode (TFFEC) array and a cold cathode electron gun based on the emitter were developed. A microwave tube gun that uses the thin film field emission cathode as an electron source is produced. State-of-the-art cathodes were fabricated and tested. The tip-packing density of the arrays were increased thereby increasing the cathode's current density capability. The TFFEC is based on the well known field emission effect and was conceived to exploit the advantages of that phenomenon while minimizing the difficulties associated with conventional field emission structures, e.g. limited life and high voltage requirements. Field emission follows the Fowler-Nordheim equation.

  5. Development of a novel thermionic RF electron gun applied on a compact THz-FEL facility

    NASA Astrophysics Data System (ADS)

    Hu, T. N.; Pei, Y. J.; Qin, B.; Liu, K. F.; Feng, G. Y.

    2018-04-01

    The current requirements from civil and commercial applications lead to the development of compact free-electron laser (FEL)-based terahertz (THz) radiation sources. A picosecond electron gun plays an important role in an FEL-THz facility and attracts significant attention, as machine performance is very sensitive to initial conditions. A novel thermionic gun with an external cathode (EC) and two independently tunable cavities (ITCs) has been found to be a promising alternative to conventional electron sources due to its remarkable characteristics, and correspondingly an FEL injector can achieve a balance between a compact layout and high brightness benefitting from the velocity bunching properties and RF focusing effects in the EC-ITC gun. Nevertheless, the EC-ITC gun has not been extensively examined as part of the FEL injector in the past years. In this regard, to fill this gap, a development focusing on the experimental setup of an FEL injector based on an EC-ITC gun is described in detail. Before assembly, dynamic beam simulations were performed to investigate the optimal mounting position for the Linac associated with the focusing coils, and a suitable radio-frequency (RF) system was established based on a power coupling design and allocation. The testing bench proved to be fully functional through basic experiments using typical diagnostic approaches for estimating primary parameters. Associated with dynamic beam calculations, a performance evaluation for an EC-ITC gun was established while providing indirect testing results for an FEL injector.

  6. Air pollution source identification

    NASA Technical Reports Server (NTRS)

    Fordyce, J. S.

    1975-01-01

    Techniques for air pollution source identification are reviewed, and some results obtained with them are evaluated. Described techniques include remote sensing from satellites and aircraft, on-site monitoring, and the use of injected tracers and pollutants themselves as tracers. The use of a large number of trace elements in ambient airborne particulate matter as a practical means of identifying sources is discussed in detail. Sampling and analysis techniques are described, and it is shown that elemental constituents can be related to specific source types such as those found in the earth's crust and those associated with specific industries. Source identification sytems are noted which utilize charged particle X-ray fluorescence analysis of original field data.

  7. High gradient rf gun studies of CsBr photocathodes

    DOE PAGES

    Vecchione, Theodore; Maldonado, Juan R.; Gierman, Stephen; ...

    2015-04-03

    CsBr photocathodes have 10 times higher quantum efficiency with only 3 times larger intrinsic transverse emittance than copper. They are robust and can withstand 80 MV/m fields without breaking down or emitting dark current. They can operate in 2×10⁻⁹ torr vacuum and survive exposure to air. They are well suited for generating high pulse charge in rf guns without a photocathode transfer system.

  8. Glue Guns: Aiming for Safety

    ERIC Educational Resources Information Center

    Roy, Ken

    2010-01-01

    While glue guns are very useful, there are safety issues. Regardless of the temperature setting, glue guns can burn skin. The teacher should demonstrate and supervise the use of glue guns and have a plan should a student get burned. There should be an initial first aid protocol in place, followed by a visit to the school nurse. An accident report…

  9. "Is there a gun in the home?" Assessing the risks of gun ownership in older adults.

    PubMed

    Pinholt, Ellen M; Mitchell, Joshua D; Butler, Jane H; Kumar, Harjinder

    2014-06-01

    An important ethical and safety concern that geriatricians, primary care providers, and home health professionals need to address is gun ownership by elderly adults. Those aged 65 and older now have the highest rate of gun ownership in America, and they also have a high prevalence of depression and suicide. Dementia can add additional layers of risk. Even older gun owners who are otherwise intellectually intact may benefit from information about gun safety with the increasing numbers of children being cared for by grandparents. Health professionals should ask patients, "Is there a gun in the home?" in the clinic and during home visits. Healthcare professionals must have knowledge and skills to address safe gun ownership in elderly adults. The 5 L's (Locked, Loaded, Little children, feeling Low, Learned owner) will assist professionals in addressing all aspects of safe ownership. © 2014, Copyright the Authors Journal compilation © 2014, The American Geriatrics Society.

  10. THz and Sub-THz Capabilities of a Table-Top Radiation Source Driven by an RF Thermionic Electron Gun

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Smirnov, Alexei V.; Agustsson, R.; Boucher, S.

    Design features and experimental results are presented for a sub-mm wave source [1] based on APS RF thermionic electron gun. The setup includes compact alpha-magnet, quadrupoles, sub-mm-wave radiators, and THz optics. The sub-THz radiator is a planar, oversized structure with gratings. Source upgrade for generation frequencies above 1 THz is discussed. The THz radiator will use a short-period undulator having 1 T field amplitude, ~20 cm length, and integrated with a low-loss oversized waveguide. Both radiators are integrated with a miniature horn antenna and a small ~90°-degree in-vacuum bending magnet. The electron beamline is designed to operate different modes includingmore » conversion to a flat beam interacting efficiently with the radiator. The source can be used for cancer diagnostics, surface defectoscopy, and non-destructive testing. Sub-THz experiment demonstrated a good potential of a robust, table-top system for generation of a narrow bandwidth THz radiation. This setup can be considered as a prototype of a compact, laser-free, flexible source capable of generation of long trains of Sub-THz and THz pulses with repetition rates not available with laser-driven sources.« less

  11. Water pressure and ground vibrations induced by water guns near Bandon Road Lock and Dam and Lemont, Illinois

    USGS Publications Warehouse

    Adams, Ryan F.; Koebel, Carolyn M.; Morrow, William S.

    2018-02-13

    surface. A combination of two 80-in3 water guns set at 6 and 8 ft, respectively, produced a similarly shaped 5 lb/in2 pressure field 30 ft in radius. Neither of the water gun configurations exceeded the given threshold of 5 lb/in2 above the static pressure along the walls of the canal at the 700 lb/in2 water gun input pressure. Velocity and acceleration data were collected simultaneously with the underwater pressure data to understand the response of adjacent canal walls to the water gun firings. Maximum velocity and acceleration were 0.239 in/s and 0.0188 feet per second squared (ft/s2), respectively.The Lemont study replicated and expanded upon work done in 2011. The pressure field created by the water gun was evaluated in a deeper environment (about 25 ft of water depth) than that of the Brandon Road study. To replicate the 2011 study, data were collected with the same water gun placements and input pressure, but static underwater pressure monitoring was added. Two 80-in3 water guns were suspended below a platform at depths of 4 and 14 ft bws. Pressure was lower when the gun suspended at 4 ft bws was fired as compared to firing the single gun suspended at 14 ft bws. Firing both guns simultaneously produced similar pressures to the single gun suspended at 14 ft bws. Data were collected to assess the pressure field produced by two 80-in3 water guns separated by 80 ft and suspended at a depth of 14 ft bws. The spatial extent of the 5-lb/in2 threshold varied substantially with gun input air pressure. Firing the water gun with an air pressure of 2,000 lb/in2 generated a pressure field greater than the threshold at all but one location in the measured region. Additionally, the water gun with an air pressure of 1,000 lb/in2 did not reach the threshold anywhere in the measured region. Maximum velocity and acceleration were 0.304 in/s and 0.015 ft/s2, respectively.

  12. Firearm retailers' willingness to participate in an illegal gun purchase.

    PubMed

    Wintemute, Garen

    2010-09-01

    Firearm-related violence is a significant public health and public safety problem for cities in the USA, and licensed firearm retailers are an important source of the guns used in that violence. Using a scripted telephone interview, we screened a sample of licensed retailers in California to assess their willingness to participate in the surrogate or "straw" purchase of a handgun; such purchases are illegal under federal law. Of 149 retailers who provided a response, 30 (20.1%) agreed to participate. In multivariate analysis, pawnbrokers were more likely to agree than were gun dealers (odds ratio 6.58, 95% confidence interval 1.99-21.71). Sales of handguns that were later subjected to ownership tracing (a proxy measure for a gun's use in crime) were not more frequent among retailers who agreed to participate than among others, and other findings were unexpected as well.

  13. Gun muzzle blast and flash

    NASA Astrophysics Data System (ADS)

    Klingenberg, Guenter; Heimerl, Joseph M.

    A repository of fundamental experimental and analytical data concerning the complex phenomena associated with gun-muzzle blast and flash effects is presented, proceeding from gun muzzle signatures to modern gun-propulsion concepts, interior and transitional ballistics, and characterizations of blast-wave research and muzzle flash. Data are presented in support of a novel hypothesis which explains the ignition of secondary flash and elucidates the means for its suppression. Both chemical and mechanical (often competing) methods of flash suppression are treated. The historical work of Kesslau and Ladenburg is noted, together with French, British, Japanese and American research efforts and current techniques of experimental characterization for gun muzzle phenomena.

  14. Source apportionment of indoor air pollution

    NASA Astrophysics Data System (ADS)

    Sexton, Ken; Hayward, Steven B.

    An understanding of the relative contributions from important pollutant sources to human exposures is necessary for the design and implementation of effective control strategies. In the past, societal efforts to control air pollution have focused almost exclusively on the outdoor (ambient) environment. As a result, substantial amounts of time and money have been spent to limit airborne discharges from mobile and stationary sources. Yet it is now recognized that exposures to elevated pollutant concentrations often occur as a result of indoor, rather than outdoor, emissions. While the major indoor sources have been identified, their relative impacts on indoor air quality have not been well defined. Application of existing source apportionment models to nonindustrial indoor environments is only just beginning. It is possible that these models might be used to distinguish between indoor and outdoor emissions, as well as to distinguish among indoor sources themselves. However, before the feasibility and suitability of source-apportionment methods for indoor applications can be assessed adequately, it is necessary to take account of model assumptions and associated data requirements. This paper examines the issue of indoor source apportionment and reviews the need for emission characterization studies to support such source-apportionment efforts.

  15. A Robust High Current Density Electron Gun

    NASA Astrophysics Data System (ADS)

    Mako, F.; Peter, W.; Shiloh, J.; Len, L. K.

    1996-11-01

    Proof-of-principle experiments are proposed to validate a new concept for a robust, high-current density Pierce electron gun (RPG) for use in klystrons and high brightness electron sources for accelerators. This rugged, long-life electron gun avoids the difficulties associated with plasma cathodes, thermionic emitters, and field emission cathodes. The RPG concept employs the emission of secondary electrons in a transmission mode as opposed to the conventional mode of reflection, i.e., electrons exit from the back face of a thin negative electron affinity (NEA) material, and in the same direction as the incident beam. Current amplification through one stage of a NEA material could be over 50 times. The amplification is accomplished in one or more stages consisting of one primary emitter and one or more secondary emitters. The primary emitter is a low current density robust emitter (e.g., thoriated tungsten). The secondary emitters are thin NEA electrodes which emit secondary electrons in the same direction as the incident beam. Specific application is targeted for a klystron gun to be used by SLAC with a cold cathode at 30-40 amps/cm^2 output from the secondary emission stage, a ~2 μs pulse length, and ~200 pulses/second.

  16. A Low Velocity 0.30-cal. Gun System

    DTIC Science & Technology

    2015-02-01

    control number. PLEASE DO NOT RETURN YOUR FORM TO THE ABOVE ADDRESS. 1. REPORT DATE (DD-MM-YYYY) February 2015 2. REPORT TYPE Final 3. DATES COVERED...298 (Rev. 8/98) Prescribed by ANSI Std. Z39.18 iii Contents List of Figures iv List of Tables iv 1. Introduction 1 2. Approach 4 3...the speed of sound in air. It is exceedingly difficult to get precise velocity control of gun-fired FSPs in this velocity regime using a

  17. Plasma-anode electron gun

    NASA Astrophysics Data System (ADS)

    Santoru, Joseph; Schumacher, Robert W.; Gregoire, Daniel J.

    1994-11-01

    The plasma-anode electron gun (PAG) is an electron source in which the thermionic cathode is replaced with a cold, secondary-electron-emitting electrode. Electron emission is stimulated by bombarding the cathode with high-energy ions. Ions are injected into the high-voltage gap through a gridded structure from a plasma source (gas pressure less than or equal to 50 mTorr) that is embedded in the anode electrode. The gridded structure serves as both a cathode for the plasma discharge and as an anode for the PAG. The beam current is modulated at near ground potential by modulating the plasma source, eliminating the need for a high-voltage modulator system. During laboratory tests, the PAG has demonstrated square-wave, 17-microsecond-long beam pulses at 100 kV and 10 A, and it has operated stably at 70 kV and 2.5 A for 210 microsecond pulse lengths without gap closure.

  18. Alignment Fixtures For Vacuum-Plasma-Spray Gun

    NASA Technical Reports Server (NTRS)

    Woodford, William H.; Mckechnie, Timothy N.; Power, Christopher A.; Daniel, Ronald L., Jr.

    1993-01-01

    Fixtures for alignment of vacuum-plasma-spray guns built. Each fixture designed to fit specific gun and holds small, battery-powered laser on centerline of gun. Laser beam projects small red dot where centerline intersects surface of workpiece to be sprayed. After laser beam positioned on surface of workpiece, fixture removed from gun and spraying proceeds.

  19. Cost Estimate for Gun Liner Emplacement

    DTIC Science & Technology

    2011-08-01

    material. The M2 machine gun has a Stellite 21 liner that covers only about one-half of the barrel length. It has been successful in reducing the...Michael R. M2 Machine Gun Barrel Wear with SLAP Ammunition. To be published in Journal of Materials and Manufacturing Processes. 8. Miller, Mark D...case in point is the use of a Stellite 21 liner in the M2 0.50-cal machine gun . However, liners have generally been difficult to place into gun tubes

  20. Advances in light-gas gun technology

    NASA Technical Reports Server (NTRS)

    Cowan, P. L.; Murphy, J. R.

    1968-01-01

    Constant-area accelerator used with light-gas guns increases the velocity of accelerating projectiles. A disposable accelerator on the muzzle of the gun uses the energy and momentum of a primary projectile, launched by the gun, to achieve high velocities of a light secondary projectile accelerated from rest in the accelerator.

  1. Superconducting 112 MHz QWR electron gun

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Belomestnykh, S.; Ben-Zvi, I.; Boulware, C.H.

    Brookhaven National Laboratory and Niowave, Inc. have designed and fabricated a superconducting 112 MHz quarter-wave resonator (QWR) electron gun. The first cold test of the QWR cryomodule has been completed at Niowave. The paper describes the cryomodule design, presents the cold test results, and outline plans to upgrade the cryomodule. Future experiments include studies of different photocathodes and use for the coherent electron cooling proof-of-principle experiment. Two cathode stalk options, one for multi-alkali photocathodes and the other one for a diamond-amplified photocathode, are discussed. A quarter-wave resonator concept of superconducting RF (SRF) electron gun was proposed at BNL for electronmore » cooling hadron beams in RHIC. QWRs can be made sufficiently compact even at low RF frequencies (long wavelengths). The long wavelength allows to produce long electron bunches, thus minimizing space charge effects and enabling high bunch charge. Also, such guns should be suitable for experiments requiring high average current electron beams. A 112 MHz QWR gun was designed, fabricated, and cold-tested in collaboration between BNL and Niowave. This is the lowest frequency SRF gun ever tested successfully. In this paper we describe the gun design and fabrication, present the cold test results, and outline our plans. This gun will also serve as a prototype for a future SRF gun to be used for coherent electron cooling of hadrons in eRHIC.« less

  2. Association Between Substance Use and Gun-Related Behaviors

    PubMed Central

    Chen, Danhong; Wu, Li-Tzy

    2016-01-01

    Gun-related violence is a public health concern. This study synthesizes findings on associations between substance use and gun-related behaviors. Searches through PubMed, Embase, and PsycINFO located 66 studies published in English between 1992 and 2014. Most studies found a significant bivariate association between substance use and increased odds of gun-related behaviors. However, their association after adjustment was mixed, which could be attributed to a number of factors such as variations in definitions of substance use and gun activity, study design, sample demographics, and the specific covariates considered. Fewer studies identified a significant association between substance use and gun access/possession than other gun activities. The significant association between nonsubstance covariates (e.g., demographic covariates and other behavioral risk factors) and gun-related behaviors might have moderated the association between substance use and gun activities. Particularly, the strength of association between substance use and gun activities tended to reduce appreciably or to become nonsignificant after adjustment for mental disorders. Some studies indicated a positive association between the frequency of substance use and the odds of engaging in gun-related behaviors. Overall, the results suggest a need to consider substance use in research and prevention programs for gun-related violence. PMID:26769722

  3. Not an 'iron pipeline', but many capillaries: regulating passive transactions in Los Angeles' secondary, illegal gun market.

    PubMed

    Chesnut, Kelsie Y; Barragan, Melissa; Gravel, Jason; Pifer, Natalie A; Reiter, Keramet; Sherman, Nicole; Tita, George E

    2017-08-01

    California has strict firearm-related laws and is exceptional in its regulation of firearms retailers. Though evidence suggests that these laws can reduce illegal access to guns, high levels of gun violence persist in Los Angeles (LA), California. This research seeks to describe the sources of guns accessed by active offenders in LA, California and reports offenders' motivations for obtaining guns. Los Angeles County Jail (LACJ) system (four facilities). Random sampling from a screened pool of eligible participants was used to conduct qualitative semistructured interviews with 140 incarcerated gun offenders in one of four (LACJ) facilities. Researchers collected data on firearm acquisition, experiences related to gun violence, and other topics, using a validated survey instrument. Grounded theory guided the collection and analysis of data. Respondents reported possession of 77 specific guns (79.2% handguns) collectively. Social networks facilitate access to illegal guns; the majority of interviewees acquired their illegal guns through a social connection (85.7%) versus an outside broker/unregulated retailer (8.5%). Most guns were obtained through illegal purchase (n=51) or gift (n=15). A quarter of gun purchasers report engaging in a passive transaction, or one initiated by another party. Passive gun buyers were motivated by concerns for personal safety and/or economic opportunity. In LA's illegal gun market, where existing social relationships facilitate access to guns across a diffuse network, individuals, influenced by both fear and economic opportunity, have frequent opportunities to illegally possess firearms through passive transactions. Gun policies should better target and minimise these transactions. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  4. Nail-Gun Injuries to the Hand

    PubMed Central

    Pierpont, Yvonne N.; Pappas-Politis, Effie; Naidu, Deepak K.; Salas, R. Emerick; Johnson, Erika L.; Payne, Wyatt G.

    2008-01-01

    Background: The nail gun is a commonly utilized tool in carpentry and construction. When used properly with appropriate safety precautions, it can facilitate production and boost efficiency; however, this powerful tool also has the potential to cause serious injury. The most common site of nail-gun injuries in both industrial and nonoccupational settings is the hand. Materials and Methods: We report on two patients with nail-gun injuries to the hand. A review of the literature and discussion of clinical evaluation and treatment of nail-gun injuries to the hand are presented. Results: Two patients present with soft tissue injuries to the hand with the nail embedded and intact at the injury site. Operative removal of the nail and wound care resulted in successful treatment in both cases. Nail-gun injuries to the hand vary in severity on the basis of the extent of structural damage. Treatment is based on the severity of injury and the presence and location of barbs on the penetrating nail. Conclusion: Healthcare providers must understand and educate patients on the prevention mechanics of nail-gun injuries. Nail-gun injuries to the hand necessitate appropriate evaluation techniques, understanding of surgical management versus nonsurgical management, and awareness of potential pitfalls in treatment. PMID:19079574

  5. Design and development of line type modulators for high impedance electron gun

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dixit, Kavita P.; Tillu, Abhijit; Chavan, Ramchandra

    Conventional line type modulators are routinely used for powering pulsed power microwave devices such as magnetrons and klystrons used for radar, medical and scientific applications. The load impedance (operating point) is fairly well defined in these cases, and makes the design of the discharging circuit of the modulator straight forward. This paper describes the Line type modulators that have been developed and being routinely used for powering the Triode Electron Gun of industrial electron linacs. The beam parameters of such guns are user defined and the pulse current varies from few mA to 800mA (typ). The beam energies requirement variesmore » from 40 keV to 80 keV. Hence the impedance offered by the electron gun to the power source (modulator) is not well defined. The load capacitance which is inclusive of the various stray capacitances along with the intrinsic gun capacitance is ∼ 200-400 pF. This capacitance, which depends on the configuration, shunts the load and makes the effective load highly capacitive with the resistive part varying over a wide range. The paper describes the design and development of conventional line type modulators for powering Electron gun load of the type described above. (author)« less

  6. Interpreting the empirical evidence on illegal gun market dynamics.

    PubMed

    Braga, Anthony A; Wintemute, Garen J; Pierce, Glenn L; Cook, Philip J; Ridgeway, Greg

    2012-10-01

    Thousands of Americans are killed by gunfire each year, and hundreds of thousands more are injured or threatened with guns in robberies and assaults. The burden of gun violence in urban areas is particularly high. Critics suggest that the results of firearm trace data and gun trafficking investigation studies cannot be used to understand the illegal supply of guns to criminals and, therefore, that regulatory and enforcement efforts designed to disrupt illegal firearms markets are futile in addressing criminal access to firearms. In this paper, we present new data to address three key arguments used by skeptics to undermine research on illegal gun market dynamics. We find that criminals rely upon a diverse set of illegal diversion pathways to acquire guns, gun traffickers usually divert small numbers of guns, newer guns are diverted through close-to-retail diversions from legal firearms commerce, and that a diverse set of gun trafficking indicators are needed to identify and shut down gun trafficking pathways.

  7. News media framing of serious mental illness and gun violence in the United States, 1997-2012.

    PubMed

    McGinty, Emma E; Webster, Daniel W; Jarlenski, Marian; Barry, Colleen L

    2014-03-01

    Recent mass shootings by persons seemingly afflicted with serious mental illness (SMI) have received extensive news media coverage and prompted national dialogue about the causes of, and policy responses to, mass shootings. News media framing of SMI as a cause of gun violence may influence public attitudes about persons with SMI and support for gun violence prevention proposals. We analyzed the content of a 25% random sample of news stories on SMI and gun violence published in 14 national and regional news sources from 1997 to 2012. Across the study period, most news coverage occurred in the wake of mass shootings, and "dangerous people" with SMI were more likely than "dangerous weapons" to be mentioned as a cause of gun violence.

  8. News Media Framing of Serious Mental Illness and Gun Violence in the United States, 1997-2012

    PubMed Central

    Webster, Daniel W.; Jarlenski, Marian; Barry, Colleen L.

    2014-01-01

    Recent mass shootings by persons seemingly afflicted with serious mental illness (SMI) have received extensive news media coverage and prompted national dialogue about the causes of, and policy responses to, mass shootings. News media framing of SMI as a cause of gun violence may influence public attitudes about persons with SMI and support for gun violence prevention proposals. We analyzed the content of a 25% random sample of news stories on SMI and gun violence published in 14 national and regional news sources from 1997 to 2012. Across the study period, most news coverage occurred in the wake of mass shootings, and “dangerous people” with SMI were more likely than “dangerous weapons” to be mentioned as a cause of gun violence. PMID:24432874

  9. Remotely controlled spray gun

    NASA Technical Reports Server (NTRS)

    Cunningham, William C. (Inventor)

    1987-01-01

    A remotely controlled spray gun is described in which a nozzle and orifice plate are held in precise axial alignment by an alignment member, which in turn is held in alignment with the general outlet of the spray gun by insert. By this arrangement, the precise repeatability of spray patterns is insured.

  10. Beam Dynamics Simulation of Photocathode RF Electron Gun at the PBP-CMU Linac Laboratory

    NASA Astrophysics Data System (ADS)

    Buakor, K.; Rimjaem, S.

    2017-09-01

    Photocathode radio-frequency (RF) electron guns are widely used at many particle accelerator laboratories due to high quality of produced electron beams. By using a short-pulse laser to induce the photoemission process, the electrons are emitted with low energy spread. Moreover, the photocathode RF guns are not suffered from the electron back bombardment effect, which can cause the limited electron current and accelerated energy. In this research, we aim to develop the photocathode RF gun for the linac-based THz radiation source. Its design is based on the existing gun at the PBP-CMU Linac Laboratory. The gun consists of a one and a half cell S-band standing-wave RF cavities with a maximum electric field of about 60 MV/m at the centre of the full cell. We study the beam dynamics of electrons traveling through the electromagnetic field inside the RF gun by using the particle tracking program ASTRA. The laser properties i.e. transverse size and injecting phase are optimized to obtain low transverse emittance. In addition, the solenoid magnet is applied for beam focusing and emittance compensation. The proper solenoid magnetic field is then investigated to find the optimum value for proper emittance conservation condition.

  11. Community gun safety in Central Pennsylvania.

    PubMed

    Wargo, Christina; Erdman, Deborah A; Smith, Jill Gray; Widom, Kenneth; Reardon, Judith

    2013-01-01

    Firearm-related injuries are a public health issue in the United States. In rural Pennsylvania, it is a familiar way of life to have a gun or guns in the home. Safety behaviors along with gun storage in the home, specifically where there are young children (aged 6 years and younger), are a concern for this level I regional resource center in rural Pennsylvania. Head Start families were surveyed regarding gun safety habits before and after safety educational activities. A noteworthy number of families reported changing behaviors regarding better safety habits for storing and use of firearms in the home postsurvey.

  12. Conceptual Design for CLIC Gun Pulser

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tang, Tao

    The Compact Linear Collider (CLIC) is a proposed future electron-positron collider, designed to perform collisions at energies from 0.5 to 5 TeV, with a nominal design optimized for 3 TeV (Dannheim, 2012). The Drive Beam Accelerator consists of a thermionic DC gun, bunching section and an accelerating section. The thermionic gun needs deliver a long (~143us) pulse of current into the buncher. A pulser is needed to drive grid of the gun to generate a stable current output. This report explores the requirements of the gun pulser and potential solutions to regulate grid current.

  13. Impurities, temperature, and density in a miniature electrostatic plasma and current source

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Den Hartog, D.J.; Craig, D.J.; Fiksel, G.

    1996-10-01

    We have spectroscopically investigated the Sterling Scientific miniature electrostatic plasma source-a plasma gun. This gun is a clean source of high density (10{sup 19} - 10{sup 20} m{sup -3}), low temperature (5 - 15 eV) plasma. A key result of our investigation is that molybdenum from the gun electrodes is largely trapped in the internal gun discharge; only a small amount escapes in the plasma flowing out of the gun. In addition, the gun plasma parameters actually improve (even lower impurity contamination and higher ion temperature) when up to 1 kA of electron current is extracted from the gun viamore » the application of an external bias. This improvement occurs because the internal gun anode no longer acts as the current return for the internal gun discharge. The gun plasma is a virtual plasma electrode capable of sourcing an electron emission current density of 1 kA/cm{sup 2}. The high emission current, small size (3 - 4 cm diameter), and low impurity generation make this gun attractive for a variety of fusion and plasma technology applications.« less

  14. Correlates of Gun Involvement and Aggressiveness among Adolescents.

    ERIC Educational Resources Information Center

    Ding, Cody S.; Nelsen, Edward A.; Lassonde, Cynthia T.

    2002-01-01

    Investigated adolescents' aggressiveness in relation to their experiences, beliefs, and attitudes concerning gun use, also noting family composition, relationships with parents, and emotionality as correlates of gun involvement and aggression. Student surveys indicated links between gun ownership and recreational use, beliefs about gun use, and…

  15. Air Pollution Source/receptor Relationships in South Coast Air Basin, CA

    NASA Astrophysics Data System (ADS)

    Gao, Ning

    This research project includes the application of some existing receptor models to study the air pollution source/receptor relationships in the South Coast Air Basin (SoCAB) of southern California, the development of a new receptor model and the testing and the modifications of some existing models. These existing receptor models used include principal component factor analysis (PCA), potential source contribution function (PSCF) analysis, Kohonen's neural network combined with Prim's minimal spanning tree (TREE-MAP), and direct trilinear decomposition followed by a matrix reconstruction. The ambient concentration measurements used in this study are a subset of the data collected during the 1987 field exercise of Southern California Air Quality Study (SCAQS). It consists of a number of gaseous and particulate pollutants analyzed from samples collected by SCAQS samplers at eight sampling sites, Anaheim, Azusa, Burbank, Claremont, Downtown Los Angeles, Hawthorne, Long Beach, and Rubidoux. Based on the information of emission inventories, meteorology and ambient concentrations, this receptor modeling study has revealed mechanisms that influence the air quality in SoCAB. Some of the mechanisms affecting the air quality in SoCAB that were revealed during this study include the following aspects. The SO_2 collected at sampling sites is mainly contributed by refineries in the coastal area and the ships equipped with oil-fired boilers off shore. Combustion of fossil fuel by automobiles dominates the emission of NO_{rm x} that is subsequently transformed and collected at sampling sites. Electric power plants also contribute HNO_3 to the sampling sites. A large feedlot in the eastern region of SoCAB has been identified as the major source of NH_3. Possible contributions from other industrial sources such as smelters and incinerators were also revealed. The results of this study also suggest the possibility of DMS (dimethylsulfide) and NH_3 emissions from off-shore sediments

  16. Gun Violence, mental health, and Connecticut physicians.

    PubMed

    Dodds, Peter R; Anderson, Caitlyn O; Dodds, Jon H

    2014-01-01

    While there is a public perception that gun violence is associated with mental illness we present evidence that it is a complex public health problem which defies simple characterizations and solutions. Only a small percentage of individuals with mental illness are at risk for extreme violence and they account for only a small percentage of gun-related homicides. Individuals who are at risk for gun violence are difficult to identify and successfully treat. The incidence, and perhaps the demographics, of gun violence vary substantially from state to state. We make a case for Connecticut physicians to study gun violence at the state level. We recommend that Connecticut physicians promote and expand upon the American Academy of Pediatrics' recommendation for creating a "safe home environment. "We suggest that guns be secured in all homes in which there are children. In addition we suggest that guns be voluntarily removed from homes in which there are individuals with a history of violence, threats of violence, depression, drug and/or alcohol abuse, and individuals with major mental illnesses who are not cooperating with therapy.

  17. Femtosecond-laser-driven photoelectron-gun for time-resolved cathodoluminescence measurement of GaN.

    PubMed

    Onuma, T; Kagamitani, Y; Hazu, K; Ishiguro, T; Fukuda, T; Chichibu, S F

    2012-04-01

    A rear-excitation femtosecond-laser-driven photoelectron gun (PE-gun) is developed for measuring time-resolved cathodoluminescence (TRCL) spectrum of wide bandgap materials and structures such as semiconductors and phosphors. The maximum quantum efficiency of a 20-nm-thick Au photocathode excited using a frequency-tripled Al(2)O(3):Ti laser under a rear-excitation configuration is 3.6×10(-6), which is a reasonable value for a PE-gun. When the distance between the front edge of the PE-gun and the observation point is 10 mm, the narrowest electron-beam (e-beam) diameter is 19 μm, which corresponds to one tenth of the laser-beam diameter and is comparable to the initial e-beam diameter of a typical W hair-pin filament of thermionic electron-gun. From the results of TRCL measurements on the freestanding GaN grown by the ammonothermal method and a GaN homoepitaxial film grown by metalorganic vapor phase epitaxy, overall response time for the present TRCL system is estimated to be 8 ps. The value is the same as that of time-resolved photoluminescence measurement using the same excitation laser pulses, meaning that the time-resolution is simply limited by the streak-camera, not by the PE-gun performance. The result of numerical simulation on the temporal e-beam broadening caused by the space-charge-effect suggests that the present PE-gun can be used as a pulsed e-beam source for spatio-time-resolved cathodoluminescence, when equipped in a scanning electron microscope. © 2012 American Institute of Physics

  18. Femtosecond-laser-driven photoelectron-gun for time-resolved cathodoluminescence measurement of GaN

    NASA Astrophysics Data System (ADS)

    Onuma, T.; Kagamitani, Y.; Hazu, K.; Ishiguro, T.; Fukuda, T.; Chichibu, S. F.

    2012-04-01

    A rear-excitation femtosecond-laser-driven photoelectron gun (PE-gun) is developed for measuring time-resolved cathodoluminescence (TRCL) spectrum of wide bandgap materials and structures such as semiconductors and phosphors. The maximum quantum efficiency of a 20-nm-thick Au photocathode excited using a frequency-tripled Al2O3:Ti laser under a rear-excitation configuration is 3.6×10-6, which is a reasonable value for a PE-gun. When the distance between the front edge of the PE-gun and the observation point is 10 mm, the narrowest electron-beam (e-beam) diameter is 19 μm, which corresponds to one tenth of the laser-beam diameter and is comparable to the initial e-beam diameter of a typical W hair-pin filament of thermionic electron-gun. From the results of TRCL measurements on the freestanding GaN grown by the ammonothermal method and a GaN homoepitaxial film grown by metalorganic vapor phase epitaxy, overall response time for the present TRCL system is estimated to be 8 ps. The value is the same as that of time-resolved photoluminescence measurement using the same excitation laser pulses, meaning that the time-resolution is simply limited by the streak-camera, not by the PE-gun performance. The result of numerical simulation on the temporal e-beam broadening caused by the space-charge-effect suggests that the present PE-gun can be used as a pulsed e-beam source for spatio-time-resolved cathodoluminescence, when equipped in a scanning electron microscope.

  19. Association Between Substance Use and Gun-Related Behaviors.

    PubMed

    Chen, Danhong; Wu, Li-Tzy

    2016-01-01

    Gun-related violence is a public health concern. This study synthesizes findings on associations between substance use and gun-related behaviors. Searches through PubMed, Embase, and PsycINFO located 66 studies published in English between 1992 and 2014. Most studies found a significant bivariate association between substance use and increased odds of gun-related behaviors. However, their association after adjustment was mixed, which could be attributed to a number of factors such as variations in definitions of substance use and gun activity, study design, sample demographics, and the specific covariates considered. Fewer studies identified a significant association between substance use and gun access/possession than other gun activities. The significant association between nonsubstance covariates (e.g., demographic covariates and other behavioral risk factors) and gun-related behaviors might have moderated the association between substance use and gun activities. Particularly, the strength of association between substance use and gun activities tended to reduce appreciably or to become nonsignificant after adjustment for mental disorders. Some studies indicated a positive association between the frequency of substance use and the odds of engaging in gun-related behaviors. Overall, the results suggest a need to consider substance use in research and prevention programs for gun-related violence. © The Author 2016. Published by Oxford University Press on behalf of the Johns Hopkins Bloomberg School of Public Health. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  20. Is There a Gun in the House? Gun Safety in the Home.

    ERIC Educational Resources Information Center

    Keller, Rosanne

    Written in a conversational style with illustrations, this booklet from a series of home literacy readers is directed at the Alaskan environment where guns are a way of life, used for food and defense from animals. But more than 10% of the 1,300 U.S. deaths from gun accidents occur in Alaska, and more than 70%, at home. Nearly half the victims are…

  1. A novel electron gun for inline MRI-linac configurations.

    PubMed

    Constantin, Dragoş E; Holloway, Lois; Keall, Paul J; Fahrig, Rebecca

    2014-02-01

    This work introduces a new electron gun geometry capable of robust functioning in the presence of a high strength external magnetic field for axisymmetric magnetic resonance imaging (MRI)-linac configurations. This allows an inline MRI-linac to operate without the need to isolate the linear accelerator (linac) using a magnetic shield. This MRI-linac integration approach not only leaves the magnet homogeneity unchanged but also provides the linac flexibility to move along the magnet axis of symmetry if the source to target distance needs to be adjusted. Simple electron gun geometry modifications of a Varian 600 C electron gun are considered and solved in the presence of an external magnetic field in order to determine a set of design principles for the new geometry. Based on these results, a new gun geometry is proposed and optimized in the fringe field of a 0.5 T open bore MRI magnet (GE Signa SP). A computer model for the 6 MeV Varian 600 C linac is used to determine the capture efficiency of the new electron gun-linac system in the presence of the fringe field of the same MRI scanner. The behavior of the new electron gun plus the linac system is also studied in the fringe fields of two other magnets, a 1.0 T prototype open bore magnet and a 1.5 T GE Conquest scanner. Simple geometrical modifications of the original electron gun geometry do not provide feasible solutions. However, these tests show that a smaller transverse cathode diameter with a flat surface and a slightly larger anode diameter could alleviate the current loss due to beam interactions with the anode in the presence of magnetic fields. Based on these findings, an initial geometry resembling a parallel plate capacitor with a hole in the anode is proposed. The optimization procedure finds a cathode-anode distance of 5 mm, a focusing electrode angle of 5°, and an anode drift tube length of 17.1 mm. Also, the linac can be displaced with ± 15 cm along the axis of the 0.5 T magnet without capture

  2. A novel electron gun for inline MRI-linac configurations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Constantin, Dragoş E., E-mail: dragos.constantin@varian.com; Fahrig, Rebecca; Holloway, Lois

    2014-02-15

    Purpose: This work introduces a new electron gun geometry capable of robust functioning in the presence of a high strength external magnetic field for axisymmetric magnetic resonance imaging (MRI)-linac configurations. This allows an inline MRI-linac to operate without the need to isolate the linear accelerator (linac) using a magnetic shield. This MRI-linac integration approach not only leaves the magnet homogeneity unchanged but also provides the linac flexibility to move along the magnet axis of symmetry if the source to target distance needs to be adjusted. Methods: Simple electron gun geometry modifications of a Varian 600C electron gun are considered andmore » solved in the presence of an external magnetic field in order to determine a set of design principles for the new geometry. Based on these results, a new gun geometry is proposed and optimized in the fringe field of a 0.5 T open bore MRI magnet (GE Signa SP). A computer model for the 6 MeV Varian 600C linac is used to determine the capture efficiency of the new electron gun-linac system in the presence of the fringe field of the same MRI scanner. The behavior of the new electron gun plus the linac system is also studied in the fringe fields of two other magnets, a 1.0 T prototype open bore magnet and a 1.5 T GE Conquest scanner. Results: Simple geometrical modifications of the original electron gun geometry do not provide feasible solutions. However, these tests show that a smaller transverse cathode diameter with a flat surface and a slightly larger anode diameter could alleviate the current loss due to beam interactions with the anode in the presence of magnetic fields. Based on these findings, an initial geometry resembling a parallel plate capacitor with a hole in the anode is proposed. The optimization procedure finds a cathode-anode distance of 5 mm, a focusing electrode angle of 5°, and an anode drift tube length of 17.1 mm. Also, the linac can be displaced with ±15 cm along the axis of the 0

  3. A novel electron gun for inline MRI-linac configurations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Constantin, Dragoş E., E-mail: dragos.constantin@varian.com; Fahrig, Rebecca; Holloway, Lois

    Purpose: This work introduces a new electron gun geometry capable of robust functioning in the presence of a high strength external magnetic field for axisymmetric magnetic resonance imaging (MRI)-linac configurations. This allows an inline MRI-linac to operate without the need to isolate the linear accelerator (linac) using a magnetic shield. This MRI-linac integration approach not only leaves the magnet homogeneity unchanged but also provides the linac flexibility to move along the magnet axis of symmetry if the source to target distance needs to be adjusted. Methods: Simple electron gun geometry modifications of a Varian 600C electron gun are considered andmore » solved in the presence of an external magnetic field in order to determine a set of design principles for the new geometry. Based on these results, a new gun geometry is proposed and optimized in the fringe field of a 0.5 T open bore MRI magnet (GE Signa SP). A computer model for the 6 MeV Varian 600C linac is used to determine the capture efficiency of the new electron gun-linac system in the presence of the fringe field of the same MRI scanner. The behavior of the new electron gun plus the linac system is also studied in the fringe fields of two other magnets, a 1.0 T prototype open bore magnet and a 1.5 T GE Conquest scanner. Results: Simple geometrical modifications of the original electron gun geometry do not provide feasible solutions. However, these tests show that a smaller transverse cathode diameter with a flat surface and a slightly larger anode diameter could alleviate the current loss due to beam interactions with the anode in the presence of magnetic fields. Based on these findings, an initial geometry resembling a parallel plate capacitor with a hole in the anode is proposed. The optimization procedure finds a cathode-anode distance of 5 mm, a focusing electrode angle of 5°, and an anode drift tube length of 17.1 mm. Also, the linac can be displaced with ±15 cm along the axis of the 0

  4. Brief use of a specific gun in a violent game does not affect attitudes towards that gun

    PubMed Central

    Engelhardt, Christopher R.; Bartholow, Bruce D.

    2016-01-01

    Although much attention has been paid to the question of whether violent video games increase aggressive behaviour, little attention has been paid to how such games might encourage antecedents of gun violence. In this study, we examined how product placement, the attractive in-game presentation of certain real-world firearm brands, might encourage gun ownership, a necessary antecedent of gun violence. We sought to study how the virtual portrayal of a real-world firearm (the Bushmaster AR-15) could influence players' attitudes towards the AR-15 specifically and gun ownership in general. College undergraduates (N = 176) played one of four modified video games in a 2 (gun: AR-15 or science-fiction control) × 2 (gun power: strong or weak) between-subjects design. Despite collecting many outcomes and examining many potential covariates and moderators, experimental assignment did little to influence outcomes of product evaluations or purchasing intentions with regard to the AR-15. Attitudes towards public policy and estimation of gun safety were also not influenced by experimental condition, although these might have been better tested by comparison against a no-violence control condition. By contrast, gender and political party had dramatic associations with all outcomes. We conclude that, if product placement shapes attitudes towards firearms, such effects will need to be studied with stronger manipulations or more sensitive measures. PMID:28018611

  5. Brief use of a specific gun in a violent game does not affect attitudes towards that gun.

    PubMed

    Hilgard, Joseph; Engelhardt, Christopher R; Bartholow, Bruce D

    2016-11-01

    Although much attention has been paid to the question of whether violent video games increase aggressive behaviour, little attention has been paid to how such games might encourage antecedents of gun violence. In this study, we examined how product placement, the attractive in-game presentation of certain real-world firearm brands, might encourage gun ownership, a necessary antecedent of gun violence. We sought to study how the virtual portrayal of a real-world firearm (the Bushmaster AR-15) could influence players' attitudes towards the AR-15 specifically and gun ownership in general. College undergraduates ( N  = 176) played one of four modified video games in a 2 (gun: AR-15 or science-fiction control) × 2 (gun power: strong or weak) between-subjects design. Despite collecting many outcomes and examining many potential covariates and moderators, experimental assignment did little to influence outcomes of product evaluations or purchasing intentions with regard to the AR-15. Attitudes towards public policy and estimation of gun safety were also not influenced by experimental condition, although these might have been better tested by comparison against a no-violence control condition. By contrast, gender and political party had dramatic associations with all outcomes. We conclude that, if product placement shapes attitudes towards firearms, such effects will need to be studied with stronger manipulations or more sensitive measures.

  6. Nail gun injuries among construction workers.

    PubMed

    Dement, John M; Lipscomb, Hester; Li, Leiming; Epling, Carol; Desai, Tejas

    2003-05-01

    Pneumatic nail guns greatly increase worker productivity and are extensively used in wood frame building construction, with especially high use in residential construction. One surveillance report of nail gun injuries in Washington State has been published; however, other literature consists largely of case reports and case series in trauma journals. The major objective of the current study was to investigate the occurrence of nail gun-associated injuries among construction workers and to identify preventable work-related factors associated with these injuries. Nail gun-related injuries occurring among a cohort of 13,347 carpenters in Ohio who worked union hours during the time period January 1, 1994, until September 30, 1997, were identified by matching the cohort with workers' compensation claims made to the Ohio Bureau of Workers' Compensation. We also analyzed workers' compensation claims for North Carolina Home Builders Association members for the period July 1996-November 1999 to identify nail gun-related injuries. Analyses included stratified analyses of claims by nature and body part injured, calculation of nail gun injury rates, and analyses of free text descriptions of injuries. Overall, nail gun injuries were responsible for 3.9 percent of workers' compensation claims with 8.3 percent to 25.5 percent of claims involving paid lost work time. The overall rate of nail gun injuries (cases per 200,000 work hours) was 0.33 in North Carolina and 0.26 in Ohio, reflecting the greater concentration of wood frame construction workers in the North Carolina population studied. Higher rates of injury were observed for carpenters in North Carolina and among residential carpenters in Ohio. The predominant body part injured was the hands/fingers, with 80 to 89 percent of injuries being nail punctures. Analyses of free text information for puncture injuries found approximately 70 percent of injuries to occur during the framing/sheathing stage of construction. Our data

  7. Source Emissions in Multipollutant Air Quality Management

    EPA Science Inventory

    Human activities and natural processes that emit pollutants into the ambient atmosphere are the underlying cause of all air quality problems. In a technical sense, we refer to these activities and processes as pollutant sources. Although air quality management is usually concerne...

  8. Near-source air pollution and mitigation strategies

    EPA Science Inventory

    Abstract. Local-scale air pollution impact is of concern for populations located in close proximity to transit sources, including highway, port, rail, and other areas of concentrated diesel emissions. Previous near-road air monitoring research has prompted the U.S. EPA to implem...

  9. GUN4-Porphyrin Complexes Bind the ChlH/GUN5 Subunit of Mg-Chelatase and Promote Chlorophyll Biosynthesis in Arabidopsis[W

    PubMed Central

    Adhikari, Neil D.; Froehlich, John E.; Strand, Deserah D.; Buck, Stephanie M.; Kramer, David M.; Larkin, Robert M.

    2011-01-01

    The GENOMES UNCOUPLED4 (GUN4) protein stimulates chlorophyll biosynthesis by activating Mg-chelatase, the enzyme that commits protoporphyrin IX to chlorophyll biosynthesis. This stimulation depends on GUN4 binding the ChlH subunit of Mg-chelatase and the porphyrin substrate and product of Mg-chelatase. After binding porphyrins, GUN4 associates more stably with chloroplast membranes and was proposed to promote interactions between ChlH and chloroplast membranes—the site of Mg-chelatase activity. GUN4 was also proposed to attenuate the production of reactive oxygen species (ROS) by binding and shielding light-exposed porphyrins from collisions with O2. To test these proposals, we first engineered Arabidopsis thaliana plants that express only porphyrin binding–deficient forms of GUN4. Using these transgenic plants and particular mutants, we found that the porphyrin binding activity of GUN4 and Mg-chelatase contribute to the accumulation of chlorophyll, GUN4, and Mg-chelatase subunits. Also, we found that the porphyrin binding activity of GUN4 and Mg-chelatase affect the associations of GUN4 and ChlH with chloroplast membranes and have various effects on the expression of ROS-inducible genes. Based on our findings, we conclude that ChlH and GUN4 use distinct mechanisms to associate with chloroplast membranes and that mutant alleles of GUN4 and Mg-chelatase genes cause sensitivity to intense light by a mechanism that is potentially complex. PMID:21467578

  10. Advanced Laser Technologies for High-brightness Photocathode Electron Gun

    NASA Astrophysics Data System (ADS)

    Tomizawa, Hiromitsu

    A laser-excited photocathode RF gun is one of the most reliable high-brightness electron beam sources for XFELs. Several 3D laser shaping methods have been developed as ideal photocathode illumination sources at SPring-8 since 2001. To suppress the emittance growth caused by nonlinear space-charge forces, the 3D cylindrical UV-pulse was optimized spatially as a flattop and temporally as squarely stacked chirped pulses. This shaping system is a serial combination of a deformable mirror that adaptively shapes the spatial profile with a genetic algorithm and a UV-pulse stacker that consists of four birefringent α-BBO crystal rods for temporal shaping. Using this 3D-shaped pulse, a normalized emittance of 1.4 π mm mrad was obtained in 2006. Utilizing laser's Z-polarization, Schottky-effect-gated photocathode gun was proposed in 2006. The cathode work functions are reduced by a laser-induced Schottky effect. As a result of focusing a radially polarized laser pulse with a hollow lens in vacuum, the Z-field (Z-polarization) is generated at the cathode.

  11. A Particle-In-Cell Gun Code for Surface-Converter H- Ion Source Modeling

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chacon-Golcher, Edwin; Bowers, Kevin J.

    2007-08-10

    We present the current status of a particle-in-cell with Monte Carlo collisions (PIC-MCC) gun code under development at Los Alamos for the study of surface-converter H- ion sources. The program preserves a first-principles approach to a significant extent and simulates the production processes without ad hoc models within the plasma region. Some of its features include: solution of arbitrary electrostatic and magnetostatic fields in an axisymmetric (r,z) geometry to describe the self-consistent time evolution of a plasma; simulation of a multi-species (e-,H+,H{sub 2}{sup +},H{sub 3}{sup +},H-) plasma discharge from a neutral hydrogen gas and filament-originated seed electrons; full 2-dimensional (r,z)more » 3-velocity (vr,vz,v{phi}) dynamics for all species with exact conservation of the canonical angular momentum p{phi}; detailed collision physics between charged particles and neutrals and the ability to represent multiple smooth (not stair-stepped) electrodes of arbitrary shape and voltage whose surfaces may be secondary-particle emitters (H- and e-). The status of this development is discussed in terms of its physics content and current implementation details.« less

  12. The Status of Normal Conducting RF (NCRF) Guns, a Summary of the ERL2005 Workshop

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dowell, D.H.; /SLAC; Lewellen, J.W.

    The 32nd Advanced ICFA Beam Dynamics Workshop on Energy Recovering Linacs (ERL2005) was held at Jefferson Laboratory, March 20 to 23, 2005. A wide range of ERL-related topics were presented and discussed in several working groups with Working Group 1 concentrated upon the physics and technology issues for DC, superconducting RF (SRF) and normal conducting RF (NCRF) guns. This paper summarizes the NCRF gun talks and reviews the status of NCRF gun technology. It begins with the presentations made on the subject of low-frequency, high-duty factor guns most appropriate for ERLs. One such gun at 433MHz was demonstrated at 25%DFmore » in 1992, while the CW and much improved version is currently being constructed at 700MHz for LANL. In addition, the idea of combining the NCRF gun with a SRF linac booster was presented and is described in this paper. There was also a talk on high-field guns typically used for SASE free electron lasers. In particular, the DESY coaxial RF feed design provides rotationally symmetric RF fields and greater flexibility in the placement of the focusing magnetic field. While in the LCLS approach, the symmetric fields are obtained with a dual RF feed and racetrack cell shape. Although these guns cannot be operated at high-duty factor, they do produce the best quality beams. With these limitations in mind, a section with material not presented at the workshop has been included in the paper. This work describes a re-entrant approach which may allow NCRF guns to operate with simultaneously increased RF fields and duty factors. And finally, a novel proposal describing a high-duty factor, two-frequency RF gun using a field emission source instead of a laser driven photocathode was also presented.« less

  13. The status of normal conducting RF (NCRF) guns; a summary of the ERL2005 Workshop

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    D.H. Dowell; J.W. Lewellen; D. Nguyen

    The 32nd Advanced ICFA Beam Dynamics Workshop on Energy Recovering Linacs (ERL2005) was held at Jefferson Laboratory, March 20 to 23, 2005. A wide range of ERL-related topics were presented and discussed in several working groups with Working Group 1 concentrated upon the physics and technology issues for DC, superconducting RF (SRF) and normal conducting RF (NCRF) guns. This paper summarizes the NCRF gun talks and reviews the status of NCRF gun technology. It begins with the presentations made on the subject of low-frequency, high-duty factor guns most appropriate for ERLs. One such gun at 433MHz was demonstrated at 25%DFmore » in 1992, while the CW and much improved version is currently being constructed at 700MHz for LANL. In addition, the idea of combining the NCRF gun with a SRF linac booster was presented and is described in this paper. There was also a talk on high-field guns typically used for SASE free electron lasers. In particular, the DESY coaxial RF feed design provides rotationally symmetric RF fields and greater flexibility in the placement of the focusing magnetic field. While in the LCLS approach, the symmetric fields are obtained with a dual RF feed and racetrack cell shape. Although these guns cannot be operated at high-duty factor, they do produce the best quality beams. With these limitations in mind, a section with material not presented at the workshop has been included in the paper. This work describes a re-entrant approach which may allow NCRF guns to operate with simultaneously increased RF fields and duty factors. And finally, a novel proposal describing a high-duty factor, two-frequency RF gun using a field emission source instead of a laser driven photocathode was also presented.« less

  14. The status of normal conducting RF (NCRF) guns, a summary of the ERL2005 workshop

    NASA Astrophysics Data System (ADS)

    Dowell, David H.; Lewellen, John W.; Nguyen, Dinh; Rimmer, Robert

    2006-02-01

    The 32nd Advanced ICFA Beam Dynamics Workshop on Energy Recovering Linacs (ERL2005) was held at Jefferson Laboratory, March 20-23, 2005. A wide range of ERL-related topics were presented and discussed in several working groups with Working Group 1 concentrating upon the physics and technology issues for DC, superconducting RF (SRF) and normal conducting RF (NCRF) guns. This paper summarizes the NCRF gun talks and reviews the status of NCRF gun technology. It begins with the presentations made on the subject of low-frequency, high-duty factor guns most appropriate for ERLs. One such gun at 433 MHz was demonstrated at 25%DF in 1992, while the CW and much improved version is currently being constructed at 700 MHz for LANL. In addition, the idea of combining the NCRF gun with a SRF linac booster was presented and is described in this paper. There was also a talk on high-field guns typically used for SASE-free electron lasers. In particular, the DESY coaxial RF feed design provides rotationally symmetric RF fields and greater flexibility in the placement of the focusing magnetic field. While in the LCLS approach, the symmetric fields are obtained with a dual RF feed and racetrack cell shape. Although these guns cannot be operated at high-duty factor, they do produce the best quality beams. With these limitations in mind, a section with material not presented at the workshop has been included in the paper. This work describes a re-entrant approach which may allow NCRF guns to operate with simultaneously increased RF fields and duty factors. And finally, a novel proposal describing a high-duty factor, two-frequency RF gun using a field emission source instead of a laser driven photocathode was also presented.

  15. Background Checks for all Gun Buyers and Gun Violence Restraining Orders: State Efforts to Keep Guns from High-Risk Persons.

    PubMed

    Vernick, Jon S; Alcorn, Ted; Horwitz, Joshua

    2017-03-01

    There were more than 36,000 firearm-related deaths in the U.S. in 2015. Under federal law, a background check is required only for gun purchases from licensed dealers. Research suggests that some persons prohibited from owning a gun turn to private sellers, including those identified online, to attempt to obtain a firearm. State-level approaches to make it more difficult for high-risk persons to purchase or possess firearms include universal background check (UBC) and gun violence restraining order (GVRO) laws. UBC laws, on the books in 18 states as of the end of 2016, can reduce both homicide and suicide rates. After Colorado adopted a UBC law in 2013, the number of background checks conducted by private sellers for sales occurring at places other than gun shows steadily increased. GVRO laws give law enforcement and families the authority to petition a court to temporarily remove firearms from an individual who presents a danger to himself or others during times of crisis, regardless of whether that person has been diagnosed with a mental illness. California enacted a GVRO law in 2014. Data are emerging to suggest the effectiveness of GVRO-type laws at averting suicides and providing an entryway to services.

  16. Extended suicide using an atypical stud gun.

    PubMed

    Hagemeier, L; Schyma, C; Madea, B

    2009-08-10

    Suicides with stud guns are uncommon, but are well documented in the literature. On rare occasions, stud guns are also used as a homicide weapon. This case report describes an extended suicide in which a husband killed his wife and their two dogs, which lived on the property. The husband then committed suicide with a shot from the stud gun into his skull. He was a 70-year-old pensioner, a retired butcher, who was found by his son. He was lying in a supine position on a carpet in the living room, with the stud gun stuck in his skull. During autopsy, high concentrations of an antihistamine were found in the blood of each corpse; this drug is used as a soporific. In contrast to the literature, which mainly describes powder deposits due to the use of conventional stud guns, in this case a stud gun was used in which the expanding gases and powder escaped together with the central bolt at the front of the device; powder drains were not involved. Detailed findings of the autopsy are given with reference to this type of stud gun.

  17. The National Near-Road Mobile Source Air Toxics Study

    EPA Science Inventory

    Recently, much attention has been directed at understanding the impact of mobile sources on near-road air quality, especially PM and its components, NOx and CO, but little information exists for mobile source air toxics (MSATs). MSATs of interest to this project are 1,3-butadiene...

  18. Ready, Fire, Aim: The College Campus Gun Fight

    ERIC Educational Resources Information Center

    Birnbaum, Robert

    2013-01-01

    The question of whether guns should be permitted on college and university campuses in the United States reflects the tension between two competing perspectives. America has both a robust gun culture and an equally robust (if less well known) gun-control culture. The gun culture is as American as apple pie: There may be as many as 300 million…

  19. Gas gun shock experiments with single-pulse x-ray phase contrast imaging and diffraction at the Advanced Photon Source

    NASA Astrophysics Data System (ADS)

    Luo, S. N.; Jensen, B. J.; Hooks, D. E.; Fezzaa, K.; Ramos, K. J.; Yeager, J. D.; Kwiatkowski, K.; Shimada, T.

    2012-07-01

    The highly transient nature of shock loading and pronounced microstructure effects on dynamic materials response call for in situ, temporally and spatially resolved, x-ray-based diagnostics. Third-generation synchrotron x-ray sources are advantageous for x-ray phase contrast imaging (PCI) and diffraction under dynamic loading, due to their high photon fluxes, high coherency, and high pulse repetition rates. The feasibility of bulk-scale gas gun shock experiments with dynamic x-ray PCI and diffraction measurements was investigated at the beamline 32ID-B of the Advanced Photon Source. The x-ray beam characteristics, experimental setup, x-ray diagnostics, and static and dynamic test results are described. We demonstrate ultrafast, multiframe, single-pulse PCI measurements with unprecedented temporal (<100 ps) and spatial (˜2 μm) resolutions for bulk-scale shock experiments, as well as single-pulse dynamic Laue diffraction. The results not only substantiate the potential of synchrotron-based experiments for addressing a variety of shock physics problems, but also allow us to identify the technical challenges related to image detection, x-ray source, and dynamic loading.

  20. The design of an electron gun switchable between immersed and Brillouin flowa)

    NASA Astrophysics Data System (ADS)

    Becker, R.; Kester, O.

    2012-02-01

    An electron gun, which can be switched from immersed flow to Brillouin flow during operation, may have advantages for charge breeders as well as for electron beam ion sources and traps (EBISTs). For EBISTs this allows to change the current density according to the repetition frequency and charge state, for charge breeders and EBISTs a lower current density in immersed flow provides higher acceptance for injected ions, while the higher current density in Brillouin flow results in shorter breeding times and a lower emittance for the extracted beam. Therefore, we have designed such a gun for an EBIS with 5 T central magnetic field and without the use of iron and moving the gun. The gun was placed in the axial fringing field of the 5 T solenoid in such a position that a gate valve can be placed between the gun and the cryostat to allow for simple maintenance. The field at the cathode surface turned out to be only 0.05 T, which is not enough to focus 50 A/cm2 at a few kV. However, if a small normal conducting solenoid is placed over the vacuum tube in position of the gun, a field of 0.1 T may be obtained. With this the use of LaB6 as cathode material results in a magnetic compression of 44 and therewith in a focused current density in the trap region of more than 2000 A/cm2. By reversing the current in the gun solenoid the cathode field can easily compensated to zero. By proper design of the electrodes and the compression region, the gun will be able to deliver a beam in Brillouin flow. While this is interesting by itself - remember the "super-compression" reported on CRYEBIS-I - any magnetic field between zero and the value for immersed flow will result in an electron beam with a wide range of adjustable high current densities. The design tools used have been INTMAG(C) for the calculation of magnetic fields, EGN2(C) for the simulation of the gun and ANALYSE(C) for detailed analysis of the results (for more information see www.egun-igun.com).

  1. The design of an electron gun switchable between immersed and Brillouin flow.

    PubMed

    Becker, R; Kester, O

    2012-02-01

    An electron gun, which can be switched from immersed flow to Brillouin flow during operation, may have advantages for charge breeders as well as for electron beam ion sources and traps (EBISTs). For EBISTs this allows to change the current density according to the repetition frequency and charge state, for charge breeders and EBISTs a lower current density in immersed flow provides higher acceptance for injected ions, while the higher current density in Brillouin flow results in shorter breeding times and a lower emittance for the extracted beam. Therefore, we have designed such a gun for an EBIS with 5 T central magnetic field and without the use of iron and moving the gun. The gun was placed in the axial fringing field of the 5 T solenoid in such a position that a gate valve can be placed between the gun and the cryostat to allow for simple maintenance. The field at the cathode surface turned out to be only 0.05 T, which is not enough to focus 50 A∕cm(2) at a few kV. However, if a small normal conducting solenoid is placed over the vacuum tube in position of the gun, a field of 0.1 T may be obtained. With this the use of LaB(6) as cathode material results in a magnetic compression of 44 and therewith in a focused current density in the trap region of more than 2000 A∕cm(2). By reversing the current in the gun solenoid the cathode field can easily compensated to zero. By proper design of the electrodes and the compression region, the gun will be able to deliver a beam in Brillouin flow. While this is interesting by itself--remember the "super-compression" reported on CRYEBIS-I--any magnetic field between zero and the value for immersed flow will result in an electron beam with a wide range of adjustable high current densities. The design tools used have been INTMAG(C) for the calculation of magnetic fields, EGN2(C) for the simulation of the gun and ANALYSE(C) for detailed analysis of the results (for more information see www.egun-igun.com).

  2. Electron gun jitter effects on beam bunching

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liu, M. S.; Iqbal, M., E-mail: muniqbal.chep@pu.edu.pk; Centre for High Energy Physics, University of the Punjab, Lahore 45590

    For routine operation of Beijing Electron Positron Collider II (BEPCII) linac, many factors may affect the beam bunching process directly or indirectly. We present the measurements and analyses of the gun timing jitter, gun high voltage jitter, and beam energy at the exit of the standard acceleration section of the linac quantitatively. Almost 80 mV and more than 200 ps of gun high voltage and time jitters have ever been measured, respectively. It was analyzed that the gun timing jitter produced severe effects on beam energy than the gun high voltage jitter, if the timing jitter exceeded 100 ps whichmore » eventually deteriorates both the beam performance and the injection rate to the storage ring.« less

  3. Numerical investigation of a laser gun injector at CEBAF

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Byung Yunn; Charles Sinclair; David Neuffer

    1993-08-23

    A laser gun injector is being developed based on the superconducting rf technologies established at CEBAF. This injector will serve as a high charge cw source for a high power free electron laser. It consists of a dc laser gun, a buncher, a cryounit and a chicane. Its space-charge-dominated performance has been thoroughly investigated using the time-consuming but more appropriate point-by-point space charge calculation method in PARMELA. The notion of ``conditioning for final bunching'' will be introduced. This concept has been built into the code and has greatly facilitated the optimization of the whole system to achieve the highest possiblemore » peak current while maintaining low emittance and low energy spread. Extensive parameter variation studies have shown that the design will perform better than the specifications.« less

  4. A Practical Example Aiding Understanding Momentum in 1D: The Water Gun Experiment

    ERIC Educational Resources Information Center

    MacLeod, Katarin

    2007-01-01

    The law of conservation of momentum is one that students often have difficulties understanding. This experiment allows students to use childhood toys to examine and calculate the muzzle velocity of their favourite water gun by using an air track, a spark timer or data logger and the law of conservation of momentum in a one-dimensional case, a…

  5. Higher-order mode rf guns

    NASA Astrophysics Data System (ADS)

    Lewellen, John W.

    2001-04-01

    Traditional photocathode rf gun design is based around the use of TM0,1,0-mode cavities. This is typically done in the interest of obtaining the highest possible gradient per unit supplied rf power and for historical reasons. In a multicell, aperture-coupled photoinjector, however, the gun as a whole is produced from strongly coupled cavities oscillating in a π mode. This design requires very careful preparation and tuning, as the field balance and resonant frequencies are easily disturbed. Side-coupled designs are often avoided because of the dipole modes introduced into the cavity fields. This paper proposes the use of a single higher-order mode rf cavity in order to generate the desired on-axis fields. It is shown that the field experienced by a beam in a higher-order mode rf gun is initially very similar to traditional 1.5- or 2.5-cell π-mode gun fields, and projected performance in terms of beam quality is also comparable. The new design has the advantages of much greater ease of fabrication, immunity from coupled-cell effects, and simpler tuning procedures. Because of the gun geometry, the possibility also exists for improved temperature stabilization and cooling for high duty-cycle applications.

  6. Air Mobility and the Development of Attack Aviation During the Vietnam War from 1965-1967

    DTIC Science & Technology

    2014-06-13

    frame covered with thin sheet metal was vulnerable to small arms and heavy machine gun fire. The most vulnerable time was during the low-level...reviewing instructions, searching existing data sources , gathering and maintaining the data needed, and completing and reviewing this collection of...of on- call aircraft necessary for tactical support. The Air Force had additional missions that received higher apportionment based on strategic and

  7. An ultrafast electron microscope gun driven by two-photon photoemission from a nanotip cathode

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bormann, Reiner; Strauch, Stefanie; Schäfer, Sascha, E-mail: schaefer@ph4.physik.uni-goettingen.de

    We experimentally and numerically investigate the performance of an advanced ultrafast electron source, based on two-photon photoemission from a tungsten needle cathode incorporated in an electron microscope gun geometry. Emission properties are characterized as a function of the electrostatic gun settings, and operating conditions leading to laser-triggered electron beams of very low emittance (below 20 nm mrad) are identified. The results highlight the excellent suitability of optically driven nano-cathodes for the further development of ultrafast transmission electron microscopy.

  8. Cobalt-Base Alloy Gun Barrel Study

    DTIC Science & Technology

    2014-07-01

    Cobalt-Base Alloy Gun Barrel Study by William S. de Rosset and Jonathan S. Montgomery ARL-RP-0491 July 2014 A reprint...21005-5069 ARL-RP-0491 July 2014 Cobalt-Base Alloy Gun Barrel Study William S. de Rosset and Jonathan S. Montgomery Weapons and Materials... Gun Barrel Study 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) William S. de Rosset and Jonathan S. Montgomery

  9. Development program on a cold cathode electron gun

    NASA Technical Reports Server (NTRS)

    Spindt, C. A.

    1979-01-01

    A prototype electron gun with a field emitter cathode capable of producing 95 mA in a 1/4 mm diameter beam at 12 kV was produced. Achievement of this goal required supporting studies in cathode fabrication, cathode performance, gun design, cathode mounting and gun fabrication. A series of empirical investigations advanced fabrication technology: More stable emitters were produced and multiple cone failure caused by chain reaction discharges were reduced. The cathode is capable of producing well over 95 mA, but a substantial collector development effort was required to demonstrate emission levels in the 100 mA region. Space charge problems made these levels difficult to achieve. Recommendations are made for future process and materials investigation. Electron gun designs were modeled and tested. A pair of two-electrode gun structures were fabricated and tested; one gun was delivered to NASA. Cathodes were pretested up to 100 mA at SRI and delivered to NASA for test in the gun structure.

  10. Arc-driven rail gun research

    NASA Technical Reports Server (NTRS)

    Ray, P. K.

    1984-01-01

    The equations describing the performance of an inductively-driven rail gun are analyzed numerically. Friction between the projectile and rails is included through an empirical formulation. The equations are applied to the experiment of Rashleigh and Marshall to obtain an estimate of energy distribution in rail guns as a function of time. The effect of frictional heat dissipation on the bore of the gun is calculated. The mechanism of plasma and projectile acceleration in a dc rail gun is described from a microscopic point of view through the establishment of the Hall field. The plasma conductivity is shown to be a tensor indicating that there is a small component of current parallel to the direction of acceleration. The plasma characteristics are evaluated as a function of plasma mass through a simple fluid mechanical analysis of the plasma. By equating the energy dissipated in the plasma with the radiation heat loss, the properties of the plasma are determined.

  11. Gun Possession among American Youth: A Discovery-Based Approach to Understand Gun Violence

    PubMed Central

    Ruggles, Kelly V.; Rajan, Sonali

    2014-01-01

    Objective To apply discovery-based computational methods to nationally representative data from the Centers for Disease Control and Preventions’ Youth Risk Behavior Surveillance System to better understand and visualize the behavioral factors associated with gun possession among adolescent youth. Results Our study uncovered the multidimensional nature of gun possession across nearly five million unique data points over a ten year period (2001–2011). Specifically, we automated odds ratio calculations for 55 risk behaviors to assemble a comprehensive table of associations for every behavior combination. Downstream analyses included the hierarchical clustering of risk behaviors based on their association “fingerprint” to 1) visualize and assess which behaviors frequently co-occur and 2) evaluate which risk behaviors are consistently found to be associated with gun possession. From these analyses, we identified more than 40 behavioral factors, including heroin use, using snuff on school property, having been injured in a fight, and having been a victim of sexual violence, that have and continue to be strongly associated with gun possession. Additionally, we identified six behavioral clusters based on association similarities: 1) physical activity and nutrition; 2) disordered eating, suicide and sexual violence; 3) weapon carrying and physical safety; 4) alcohol, marijuana and cigarette use; 5) drug use on school property and 6) overall drug use. Conclusions Use of computational methodologies identified multiple risk behaviors, beyond more commonly discussed indicators of poor mental health, that are associated with gun possession among youth. Implications for prevention efforts and future interdisciplinary work applying computational methods to behavioral science data are described. PMID:25372864

  12. Gun possession among American youth: a discovery-based approach to understand gun violence.

    PubMed

    Ruggles, Kelly V; Rajan, Sonali

    2014-01-01

    To apply discovery-based computational methods to nationally representative data from the Centers for Disease Control and Preventions' Youth Risk Behavior Surveillance System to better understand and visualize the behavioral factors associated with gun possession among adolescent youth. Our study uncovered the multidimensional nature of gun possession across nearly five million unique data points over a ten year period (2001-2011). Specifically, we automated odds ratio calculations for 55 risk behaviors to assemble a comprehensive table of associations for every behavior combination. Downstream analyses included the hierarchical clustering of risk behaviors based on their association "fingerprint" to 1) visualize and assess which behaviors frequently co-occur and 2) evaluate which risk behaviors are consistently found to be associated with gun possession. From these analyses, we identified more than 40 behavioral factors, including heroin use, using snuff on school property, having been injured in a fight, and having been a victim of sexual violence, that have and continue to be strongly associated with gun possession. Additionally, we identified six behavioral clusters based on association similarities: 1) physical activity and nutrition; 2) disordered eating, suicide and sexual violence; 3) weapon carrying and physical safety; 4) alcohol, marijuana and cigarette use; 5) drug use on school property and 6) overall drug use. Use of computational methodologies identified multiple risk behaviors, beyond more commonly discussed indicators of poor mental health, that are associated with gun possession among youth. Implications for prevention efforts and future interdisciplinary work applying computational methods to behavioral science data are described.

  13. Gun ownership and firearm-related deaths.

    PubMed

    Bangalore, Sripal; Messerli, Franz H

    2013-10-01

    A variety of claims about possible associations between gun ownership rates, mental illness burden, and the risk of firearm-related deaths have been put forward. However, systematic data on this issue among various countries remain scant. Our objective was to assess whether the popular notion "guns make a nation safer" has any merits. Data on gun ownership were obtained from the Small Arms Survey, and for firearm-related deaths from a European detailed mortality database (World Health Organization), the National Center for Health Statistics, and others. Crime rate was used as an indicator of safety of the nation and was obtained from the United Nations Surveys of Crime Trends. Age-standardized disability-adjusted life-year rates due to major depressive disorder per 100,000 inhabitants with data obtained from the World Health Organization database were used as a putative indicator for mental illness burden in a given country. Among the 27 developed countries, there was a significant positive correlation between guns per capita per country and the rate of firearm-related deaths (r = 0.80; P <.0001). In addition, there was a positive correlation (r = 0.52; P = .005) between mental illness burden in a country and firearm-related deaths. However, there was no significant correlation (P = .10) between guns per capita per country and crime rate (r = .33), or between mental illness and crime rate (r = 0.32; P = .11). In a linear regression model with firearm-related deaths as the dependent variable with gun ownership and mental illness as independent covariates, gun ownership was a significant predictor (P <.0001) of firearm-related deaths, whereas mental illness was of borderline significance (P = .05) only. The number of guns per capita per country was a strong and independent predictor of firearm-related death in a given country, whereas the predictive power of the mental illness burden was of borderline significance in a multivariable model. Regardless of exact

  14. Hot air heat gun

    NASA Astrophysics Data System (ADS)

    Poston, Terry L.

    1989-10-01

    The invention relates generally to the art of self-contained heating devices and in particular to portable heating devices employing chemical reaction to produce heat. Currently, hand-held heat sources, capable of producing heat at a sufficiently high temperature to activate heat-shrink material, rely on either the combustion of flammable material or electrical power to provide energy for generating the required heat. An object of the present invention is to provide a portable device capable of providing sufficient heat to shrink heat-shrinkable tubing. A further object of the invention is to provide a non-flammable heat source suitable for use in the presence of explosive atmospheres. Still another object of the invention is to provide a portable hand-held device for generating heat which can be directed to a specific location on a work surface.

  15. Improved Orifice Plate for Spray Gun

    NASA Technical Reports Server (NTRS)

    Cunningham, W.

    1986-01-01

    Erratic spray pattern of commercial spray gun changed to repeatable one by simple redesign of two parts. In modified spray gun orifice plate and polytetrafluoroethylene bushing redesigned to assure centering and alignment with nozzle. Such improvement useful in many industrial applications requiring repeatable spray patterns. Might include spraying of foam insulation, paint, other protective coatings, detergents, abrasives, adhesives, process chemicals, or fuels. Unmodified spray gun produces erratic spray because lateral misalignment between orifice plate and nozzle.

  16. Frequency of Guns in the Households of High School Seniors*

    PubMed Central

    Coker, Ann L.; Bush, Heather M.; Follingstad, Diane R.; Brancato, Candace J.

    2017-01-01

    BACKGROUND In 2013, President Obama lifted the federal ban on gun violence research. The current study provides one of the first reports to estimate household gun ownership as reported by youth. METHODS In this cohort study of 3006 high school seniors from 24 schools, we examined the frequency of household guns ownership. RESULTS About 65% reported having at least 1 gun in their household. White males were more likely to have a gun and to have more guns than other demographically characterized groups. After adjustment for race and sex, those of higher income, who lived in suburban or rural areas, identified as being exclusively attracted to the opposite sex, and in a romantic relationship, were more likely to have a gun in their household. Having a gun was not associated with increasing symptoms of depression or current poor physical or mental health. CONCLUSIONS Whereas we cannot determine gun types or reasons for having a gun, this research indicates that high school seniors are aware of and may have access to guns for use other than their intended purpose. Household gun ownership among students at higher risk for violence may pose safety challenges for communities and schools. PMID:28147456

  17. Frequency of Guns in the Households of High School Seniors.

    PubMed

    Coker, Ann L; Bush, Heather M; Follingstad, Diane R; Brancato, Candace J

    2017-03-01

    In 2013, President Obama lifted the federal ban on gun violence research. The current study provides one of the first reports to estimate household gun ownership as reported by youth. In this cohort study of 3006 high school seniors from 24 schools, we examined the frequency of household guns ownership. About 65% reported having at least 1 gun in their household. White males were more likely to have a gun and to have more guns than other demographically characterized groups. After adjustment for race and sex, those of higher income, who lived in suburban or rural areas, identified as being exclusively attracted to the opposite sex, and in a romantic relationship, were more likely to have a gun in their household. Having a gun was not associated with increasing symptoms of depression or current poor physical or mental health. Whereas we cannot determine gun types or reasons for having a gun, this research indicates that high school seniors are aware of and may have access to guns for use other than their intended purpose. Household gun ownership among students at higher risk for violence may pose safety challenges for communities and schools. © 2017, American School Health Association.

  18. Unintentional Gun Deaths among Children. Firearm Facts.

    ERIC Educational Resources Information Center

    Duker, Laurie, Ed.

    Children are at risk of being killed or injured by a gun if their parents own a gun because many guns obtained for self-defense are kept loaded and within reach of children. This brief fact sheet presents statistical information relating to accidental deaths involving young people and firearms. Safety measures are suggested for preventing…

  19. Mole gun injury.

    PubMed

    Pistré, V; Rezzouk, J

    2013-09-01

    A mole gun is a weapon, which is used to trap and kill moles. This report provides an overview of the state of knowledge of mole gun injuries, comparable to blast injuries caused by fireworks, explosive or gunshot. Over a 2-year period, the authors reported their experience with ten hand injuries caused by mole gun. Radial side of the hand was often concerned, particularly the thumb. The authors explain their choices in the management of such lesions. Surgery was performed primarily and a large debridement currently seemed to offer the best outcome for the patient. Blast, crush, burns and lacerations may explain the higher rate of amputation to the digits. A long period of physiotherapy, specifically of the hand, was needed before the patient could return to work. This ballistic hand trauma encountered by surgeons requires knowledge and understanding of these injuries. It should be in accordance with firearms law because of severe injuries encountered and possible lethal wounds. Copyright © 2013 Elsevier Masson SAS. All rights reserved.

  20. In vitro fatigue behaviour of vacuum plasma and detonation gun sprayed hydroxyapatite coatings.

    PubMed

    Gledhill, H C; Turner, I G; Doyle, C

    2001-06-01

    The fatigue behaviour of vacuum plasma sprayed (VPS) and detonation gun sprayed (DGUN) hydroxyapatite coatings on titanium substrates has been compared in air and in buffered Ringer's solution. There was an increase in the surface microcracking and bulk porosity of both types of coating tested in air. After 1 million cycles in Ringer's solution the VPS coatings had completely delaminated from their substrates. In contrast the DGUN coatings retained their integrity when tested up to 10 million cycles but were beginning to show signs of delamination at the interface.

  1. "Gun-shooting hearing loss": A pilot study.

    PubMed

    Sataloff, Joseph; Hawkshaw, Mary J; Sataloff, Robert T

    2010-01-01

    Gun-shooting deafness is the common terminology applied to sensorineural hearing loss caused by shooting firearms. Many characteristics of gun-shooting hearing loss have been proposed, but they have not been defined clearly or established conclusively. We studied 37 users of recreational firearms to obtain pilot data to help determine if it is true that right-handed gun shooters develop more hearing loss in the left ear and vice versa, whether everyone who frequently shoots guns develops sensorineural hearing loss, and whether significant hearing loss is typically prevented by wearing commercially available ear protectors while shooting.

  2. Patterns of gun deaths across US counties 1999-2013.

    PubMed

    Kalesan, Bindu; Galea, Sandro

    2017-05-01

    We examined the socio-demographic distribution of gun deaths across 3143 counties in 50 United States' states to understand the spatial patterns and correlates of high and low gun deaths. We used aggregate counts of gun deaths and population in all counties from 1999 to 2013 from the Centers for Disease Control and Prevention's Wide-ranging Online Data for Epidemiologic Research (WONDER). We characterized four levels of gun violence, as distinct levels of gun death rates of relatively safe, unsafe, violent, and extremely violent counties, based on quartiles of 15-year county-specific gun death rates per 100,000 and used negative binomial regression models allowing clustering by state to calculate incidence rate ratios and 95% confidence intervals (95% CIs). Most states had at least one violent or extremely violent county. Extremely violent gun counties were mostly rural, poor, predominantly minority, had high unemployment rate and homicide rate. Overall, homicide rate was significantly associated with gun deaths (incidence rate ratios = 1.08, 95% CI = 1.06-1.09). In relatively safe counties, this risk was 1.09 (95% CI = 1.05-1.13) and in extremely violent gun counties was 1.03 (95% CI = 1.03-1.04). There are broad differences in gun death rates across the United States representing different levels of gun death rates in each state with distinct socio-demographic profiles. Copyright © 2017 Elsevier Inc. All rights reserved.

  3. Acute Alcohol Consumption, Alcohol Outlets, and Gun Suicide

    PubMed Central

    Branas, Charles C.; Richmond, Therese S.; Ten Have, Thomas R.; Wiebe, Douglas J.

    2014-01-01

    A case–control study of 149 intentionally self-inflicted gun injury cases (including completed gun suicides) and 302 population-based controls was conducted from 2003 to 2006 in a major US city. Two focal independent variables, acute alcohol consumption and alcohol outlet availability, were measured. Conditional logistic regression was adjusted for confounding variables. Gun suicide risk to individuals in areas of high alcohol outlet availability was less than the gun suicide risk they incurred from acute alcohol consumption, especially to excess. This corroborates prior work but also uncovers new information about the relationships between acute alcohol consumption, alcohol outlets, and gun suicide. Study limitations and implications are discussed. PMID:21929327

  4. Acute alcohol consumption, alcohol outlets, and gun suicide.

    PubMed

    Branas, Charles C; Richmond, Therese S; Ten Have, Thomas R; Wiebe, Douglas J

    2011-01-01

    A case-control study of 149 intentionally self-inflicted gun injury cases (including completed gun suicides) and 302 population-based controls was conducted from 2003 to 2006 in a major US city. Two focal independent variables, acute alcohol consumption and alcohol outlet availability, were measured. Conditional logistic regression was adjusted for confounding variables. Gun suicide risk to individuals in areas of high alcohol outlet availability was less than the gun suicide risk they incurred from acute alcohol consumption, especially to excess. This corroborates prior work but also uncovers new information about the relationships between acute alcohol consumption, alcohol outlets, and gun suicide. Study limitations and implications are discussed.

  5. Separating Batterers and Guns: A Review and Analysis of Gun Removal Laws in 50 States

    ERIC Educational Resources Information Center

    Frattaroli, Shannon; Vernick, Jon S.

    2006-01-01

    Firearms play an important role in lethal domestic violence incidents. The authors review state laws regarding two policies to separate batterers from firearms: laws authorizing police to remove firearms when responding to a domestic violence complaint ("police gun removal laws") and laws authorizing courts to order guns removed from batterers…

  6. Car indoor air pollution - analysis of potential sources

    PubMed Central

    2011-01-01

    The population of industrialized countries such as the United States or of countries from the European Union spends approximately more than one hour each day in vehicles. In this respect, numerous studies have so far addressed outdoor air pollution that arises from traffic. By contrast, only little is known about indoor air quality in vehicles and influences by non-vehicle sources. Therefore the present article aims to summarize recent studies that address i.e. particulate matter exposure. It can be stated that although there is a large amount of data present for outdoor air pollution, research in the area of indoor air quality in vehicles is still limited. Especially, knowledge on non-vehicular sources is missing. In this respect, an understanding of the effects and interactions of i.e. tobacco smoke under realistic automobile conditions should be achieved in future. PMID:22177291

  7. Mobile source air toxics mitigation measures.

    DOT National Transportation Integrated Search

    2013-10-01

    In accordance with the Federal Highway Administration (FHWA) Interim Guidance Update on Mobile Source Air Toxic Analysis in NEPA Documents (September 30, 2009), transportation projects subject to the National Environmental Policy Act (NEPA) mus...

  8. Magnetized Target Fusion Propulsion: Plasma Injectors for MTF Guns

    NASA Technical Reports Server (NTRS)

    Griffin, Steven T.

    2003-01-01

    To achieve increased payload size and decreased trip time for interplanetary travel, a low mass, high specific impulse, high thrust propulsion system is required. This suggests the need for research into fusion as a source of power and high temperature plasma. The plasma would be deflected by magnetic fields to provide thrust. Magnetized Target Fusion (MTF) research consists of several related investigations into these topics. These include the orientation and timing of the plasma guns and the convergence and interface development of the "pusher" plasma. Computer simulations of the gun as it relates to plasma initiation and repeatability are under investigation. One of the items under development is the plasma injector. This is a surface breakdown driven plasma generator designed to function at very low pressures. The performance, operating conditions and limitations of these injectors need to be determined.

  9. High Current, High Density Arc Plasma as a New Source for WiPAL

    NASA Astrophysics Data System (ADS)

    Waleffe, Roger; Endrizzi, Doug; Myers, Rachel; Wallace, John; Clark, Mike; Forest, Cary; WiPAL Team

    2016-10-01

    The Wisconsin Plasma Astrophysics Lab (WiPAL) has installed a new array of nineteen plasma sources (plasma guns) on its 3 m diameter, spherical vacuum vessel. Each gun is a cylindrical, molybdenum, washer-stabilized, arc plasma source. During discharge, the guns are maintained at 1.2 kA across 100 V for 10 ms by the gun power supply establishing a high density plasma. Each plasma source is fired independently allowing for adjustable plasma parameters, with densities varying between 1018 -1019 m-3 and electron temperatures of 5-15 eV. Measurements were characterized using a 16 tip Langmuir probe. The plasma source will be used as a background plasma for the magnetized coaxial plasma gun (MCPG), the Terrestrial Reconnection Experiment (TREX), and as the plasma source for a magnetic mirror experiment. Temperature, density, and confinement results will be presented. This work is supported by the DoE and the NSF.

  10. High-voltage testing of a 500-kV dc photocathode electron gun.

    PubMed

    Nagai, Ryoji; Hajima, Ryoichi; Nishimori, Nobuyuki; Muto, Toshiya; Yamamoto, Masahiro; Honda, Yosuke; Miyajima, Tsukasa; Iijima, Hokuto; Kuriki, Masao; Kuwahara, Makoto; Okumi, Shoji; Nakanishi, Tsutomu

    2010-03-01

    A high-voltage dc photocathode electron gun was successfully conditioned up to a voltage of 550 kV and a long-time holding test for 8 h was demonstrated at an acceleration voltage of 500 kV. The dc photocathode electron gun is designed for future light sources based on energy-recovery linac and consists of a Cockcroft-Walton generator, a segmented cylindrical ceramic insulator, guard-ring electrodes, a support-rod electrode, a vacuum chamber, and a pressurized insulating gas tank. The segmented cylindrical ceramic insulator and the guard-ring electrodes were utilized to prevent any damage to the insulator from electrons emitted by the support-rod electrode.

  11. Sequential injection gas guns for accelerating projectiles

    DOEpatents

    Lacy, Jeffrey M [Idaho Falls, ID; Chu, Henry S [Idaho Falls, ID; Novascone, Stephen R [Idaho Falls, ID

    2011-11-15

    Gas guns and methods for accelerating projectiles through such gas guns are described. More particularly, gas guns having a first injection port located proximate a breech end of a barrel and a second injection port located longitudinally between the first injection port and a muzzle end of the barrel are described. Additionally, modular gas guns that include a plurality of modules are described, wherein each module may include a barrel segment having one or more longitudinally spaced injection ports. Also, methods of accelerating a projectile through a gas gun, such as injecting a first pressurized gas into a barrel through a first injection port to accelerate the projectile and propel the projectile down the barrel past a second injection port and injecting a second pressurized gas into the barrel through the second injection port after passage of the projectile and to further accelerate the projectile are described.

  12. Toroid Joining Gun For Fittings And Couplings

    NASA Technical Reports Server (NTRS)

    Fox, Robert L.; Swaim, Robert J.; Johnson, Samuel D.; Buckley, John D.; Copeland, Carl E.; Coultrip, Robert H.; Johnston, David F.; Phillips, William M.

    1992-01-01

    Hand-held gun used to join metal heat-to-shrink couplings. Uses magnetic induction (eddy currents) to produce heat in metal coupling, and thermocouple to measure temperature and signals end of process. Gun, called "toroid joining gun" concentrates high levels of heat in localized areas. Reconfigured for use on metal heat-to-shrink fitting and coupling applications. Provides rapid heating, operates on low power, lightweight and portable. Safe for use around aircraft fuel and has no detrimental effects on surrounding surfaces or objects. Reliable in any environment and under all weather conditions. Gun logical device for taking full advantage of capabilities of new metal heat-to-shrink couplings and fittings.

  13. NASA-Ames vertical gun

    NASA Technical Reports Server (NTRS)

    Schultz, P. H.

    1984-01-01

    A national facility, the NASA-Ames vertical gun range (AVGR) has an excellent reputation for revealing fundamental aspects of impact cratering that provide important constraints for planetary processes. The current logistics in accessing the AVGR, some of the past and ongoing experimental programs and their relevance, and the future role of this facility in planetary studies are reviewed. Publications resulting from experiments with the gun (1979 to 1984) are listed as well as the researchers and subjects studied.

  14. Gun Concerns Personal for Duncan

    ERIC Educational Resources Information Center

    McNeil, Michele

    2013-01-01

    As U.S. Secretary of Education Arne Duncan works with other Obama administration officials on policy responses to the shootings at a Connecticut elementary school, he brings a personal and professional history that has acquainted him with the impact of gun violence. As schools chief in Chicago from 2001 to 2008, he was affected by the gun deaths…

  15. Gun Safety Management with Patients at Risk for Suicide

    ERIC Educational Resources Information Center

    Simon, Robert I.

    2007-01-01

    Guns in the home are associated with a five-fold increase in suicide. All patients at risk for suicide must be asked if guns are available at home or easily accessible elsewhere, or if they have intent to buy or purchase a gun. Gun safety management requires a collaborative team approach including the clinician, patient, and designated person…

  16. Development of spray guns for the application of rigid foam insulation

    NASA Technical Reports Server (NTRS)

    Allen, Peter B.

    1993-01-01

    The paper describes the activities initiated to improve the existing spray gun system used for spraying insulating foam on the External Tank of the Space Shuttle, due to the quality variations of the applied foam noted in the past. Consideration is given to the two tasks of the project: (1) investigations of possible improvements, as an interim measure, to the spray gun currently used to apply the large acreage spray-on-foam insulation and the evaluation of other commercial equipment; and (2) the design and fabrication of a new automatic spray gun. The design and operation of the currently used Binks 43 PA spray gun are described together with several new breadboard spray guns designed and fabricated and the testing procedures developed. These new guns include the Modular Automatic Foam spray gun, the Ball Valve spray gun, and the Tapered Plug Valve (TPV) gun. As a result of tests, the TPV spray gun is recommended to replace the currently used automatic spray gun.

  17. 49 CFR 232.107 - Air source requirements and cold weather operations.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 4 2011-10-01 2011-10-01 false Air source requirements and cold weather... source requirements and cold weather operations. (a) Monitoring plans for yard air sources. (1) A... to the equipment and territory of that railroad to cover safe train operations during cold weather...

  18. Performance of a carbon nanotube field emission electron gun

    NASA Astrophysics Data System (ADS)

    Getty, Stephanie A.; King, Todd T.; Bis, Rachael A.; Jones, Hollis H.; Herrero, Federico; Lynch, Bernard A.; Roman, Patrick; Mahaffy, Paul

    2007-04-01

    A cold cathode field emission electron gun (e-gun) based on a patterned carbon nanotube (CNT) film has been fabricated for use in a miniaturized reflectron time-of-flight mass spectrometer (RTOF MS), with future applications in other charged particle spectrometers, and performance of the CNT e-gun has been evaluated. A thermionic electron gun has also been fabricated and evaluated in parallel and its performance is used as a benchmark in the evaluation of our CNT e-gun. Implications for future improvements and integration into the RTOF MS are discussed.

  19. Law Enforcement and Gun Retailers as Partners for Safely Storing Guns to Prevent Suicide: A Study in 8 Mountain West States.

    PubMed

    Runyan, Carol W; Brooks-Russell, Ashley; Brandspigel, Sara; Betz, Marian; Tung, Gregory; Novins, Douglas; Agans, Robert

    2017-11-01

    To examine the extent to which law enforcement agencies (LEAs) and gun retailers are willing to offer voluntary, temporary storage as a part of an overall suicide prevention effort. We invited all LEAs and gun retailers in 8 US states to respond to questionnaires asking about their willingness to offer temporary gun storage and their recommendations to gun owners about safe storage. We collected data in 2016 from 448 LEAs and 95 retailers (response rates of 53% and 25%, respectively). Three quarters of LEAs (74.8%; 95% confidence interval [CI] = 72.1, 77.5) indicated they already provided temporary storage compared with 47.6% (95% CI = 39.2, 56.0) of retailers. LEAs were most willing to provide storage when a gun owner was concerned about the mental health of a family member. Retailers were more receptive than were LEAs to providing storage when visitors were coming or for people wanting storage while traveling. Both groups recommended locking devices within the home, but LEAs were slightly more favorable to storing guns away from the home. Law enforcement agencies and gun retailers are important resources for families concerned about suicide.

  20. X-band RF gun and linac for medical Compton scattering X-ray source

    NASA Astrophysics Data System (ADS)

    Dobashi, Katsuhito; Uesaka, Mitsuru; Fukasawa, Atsushi; Sakamoto, Fumito; Ebina, Futaro; Ogino, Haruyuki; Urakawa, Junji; Higo, Toshiyasu; Akemoto, Mitsuo; Hayano, Hitoshi; Nakagawa, Keiichi

    2004-12-01

    Compton scattering hard X-ray source for 10-80 keV are under construction using the X-band (11.424 GHz) electron linear accelerator and YAG laser at Nuclear Engineering Research laboratory, University of Tokyo. This work is a part of the national project on the development of advanced compact medical accelerators in Japan. National Institute for Radiological Science is the host institute and U.Tokyo and KEK are working for the X-ray source. Main advantage is to produce tunable monochromatic hard (10-80 keV) X-rays with the intensities of 108-1010 photons/s (at several stages) and the table-top size. Second important aspect is to reduce noise radiation at a beam dump by adopting the deceleration of electrons after the Compton scattering. This realizes one beamline of a 3rd generation SR source at small facilities without heavy shielding. The final goal is that the linac and laser are installed on the moving gantry. We have designed the X-band (11.424 GHz) traveling-wave-type linac for the purpose. Numerical consideration by CAIN code and luminosity calculation are performed to estimate the X-ray yield. X-band thermionic-cathode RF-gun and RDS(Round Detuned Structure)-type X-band accelerating structure are applied to generate 50 MeV electron beam with 20 pC microbunches (104) for 1 microsecond RF macro-pulse. The X-ray yield by the electron beam and Q-switch Nd:YAG laser of 2 J/10 ns is 107 photons/RF-pulse (108 photons/sec at 10 pps). We design to adopt a technique of laser circulation to increase the X-ray yield up to 109 photons/pulse (1010 photons/s). 50 MW X-band klystron and compact modulator have been constructed and now under tuning. The construction of the whole system has started. X-ray generation and medical application will be performed in the early next year.

  1. WORKSHOP ON SOURCE EMISSION AND AMBIENT AIR MONITORING OF MERCURY

    EPA Science Inventory

    AN EPA/ORD Workshop on Source Emission and Ambient Air Monitoring of Mercury was held on 9/13-14/99, Bloomington, Minnesota. The purpose of the workshop was to discuss the state-of-the-science in source and ambient air mercury monitoring as well as mercury monitoring research and...

  2. Analysis of magnetically immersed electron guns with non-adiabatic fields.

    PubMed

    Pikin, Alexander; Alessi, James G; Beebe, Edward N; Raparia, Deepak; Ritter, John

    2016-11-01

    Electron diode guns, which have strongly varying magnetic or electric fields in a cathode-anode gap, were investigated in order to generate laminar electron beams with high current density using magnetically immersed guns. By creating a strongly varying radial electric field in a cathode-anode gap of the electron gun, it was demonstrated that the optical properties of the gun can be significantly altered, which allows the generation of a laminar, high-current electron beam with relatively low magnetic field on the cathode. The relatively high magnetic compression of the electron beam achieved by this method is important for producing electron beams with high current density. A similar result can be obtained by inducing a strong variation of the magnetic field in a cathode-anode gap. It was observed that creating a dip in the axial magnetic field in the cathode-anode gap of an adiabatic electron gun has an optical effect similar to guns with strong variation of radial electric field. By analyzing the electron trajectories angles and presenting the results in a gun performance map, different geometries of magnetically immersed electron guns with non-adiabatic fields are compared with each other and with a more traditional adiabatic electron gun. Some advantages and limitations of guns with non-adiabatic fields are outlined. The tests' results of a non-adiabatic electron gun with modified magnetic field are presented.

  3. Atmospheric aerosol source identification and estimates of source contributions to air pollution in Dundee, UK

    NASA Astrophysics Data System (ADS)

    Qin, Y.; Oduyemi, K.

    Anthropogenic aerosol (PM 10) emission sources sampled at an air quality monitoring station in Dundee have been analysed. However, the information on local natural aerosol emission sources was unavailable. A method that combines receptor model and atmospheric dispersion model was used to identify aerosol sources and estimate source contributions to air pollution. The receptor model identified five sources. These are aged marine aerosol source with some chlorine replaced by sulphate, secondary aerosol source of ammonium sulphate, secondary aerosol source of ammonium nitrate, soil and construction dust source, and incinerator and fuel oil burning emission source. For the vehicle emission source, which has been comprehensively described in the atmospheric emission inventory but cannot be identified by the receptor model, an atmospheric dispersion model was used to estimate its contributions. In Dundee, a significant percentage, 67.5%, of the aerosol mass sampled at the study station could be attributed to the six sources named above.

  4. Utility of indices of gun availability in the community.

    PubMed

    Shenassa, Edmond D; Daskalakis, Constantine; Buka, Stephen L

    2006-01-01

    To estimate the degree to which the proportion of homicides and suicides committed with a gun is associated with reported availability of firearms across Chicago neighbourhoods. Data were collected as part of the Project on Human Development in Chicago Neighborhoods (PHDCN), a combined neighbourhood and individual level study of the city of Chicago. The study used data from 837 PHDCN participants between the ages of 17 and 22, residing in 170 different neighbourhoods. Gun availability was measured via participant reports on whether they had carried a gun and whether they perceived gun access to be easy in their community. Data on suicides and homicides were obtained from the Chicago Department of Health. A 10% change in the proportion of homicides committed by a gun in a neighbourhood was associated with a 20% increase in both the odds of reported gun access and reported gun carrying (p=0.002 and 0.048, respectively). The proportion of firearm related suicides was not associated with either of those self reported measures. The proportion of firearm related homicides, but not the proportion of firearm related suicides, is a useful predictor of gun availability across small areas such as neighbourhoods.

  5. EVALUATING SOURCES OF INDOOR AIR POLLUTION

    EPA Science Inventory

    The article discusses a three-phase approach, employing environmental chambers, indoor air quality (IAQ) models, and test house experiments, that is effective in linking sources of indoor pollutants to measured concentrations. mission factors developed in test chambers can be use...

  6. Physicians Asking Patients About Guns: Promoting Patient Safety, Respecting Patient Rights.

    PubMed

    Parent, Brendan

    2016-10-01

    Recent debate on whether physicians should discuss gun ownership with their patients has centered on determining whether gun injuries are an issue of health or safety, and on protecting patient privacy. Yet, physicians' duties span personal health, public health, and safety spheres, and they often must address private patient matters. To prioritize gun safety and reduce gun injuries, the primary policy-driving question should be: will physician counseling on gun ownership effectively reduce gun-related injuries without interfering with the physician's other treatment obligations or compromising the physician-patient relationship? Existing data on physician-initiated conversations with patients about guns support a positive prevention effect. However, it is critical that physician-initiated discussions of safe gun practices are not motivated by, nor convey, disapproval of gun ownership. To be ethical, respectful, and efficient, the conversation should be standard between primary care providers and all of their patients (not limited to patient subsets); questions and education should be limited to topics of gun-ownership risks and storage practices; and the conversation must be framed without bias against gun ownership.

  7. Gun buyback programs: a venue to eliminate unwanted guns in the community.

    PubMed

    Violano, Pina; Driscoll, Cassandra; Chaudhary, Neil K; Schuster, Kevin M; Davis, Kimberly A; Borer, Esther; Winters, Jane K; Hirsh, Michael P

    2014-09-01

    The United States has a high rate of death due to firearms, and gun buyback programs may mitigate these high death rates. Understanding the demographics, motivation, and geographic region of participants may improve program efficacy. Three Injury Free Coalition for Kids gun buyback programs, in collaboration with the local police, were studied: Phoenix, Arizona; Worcester, Massachusetts; and New Haven, Connecticut. Participants were defined as those who relinquished a firearm. A self-administered, anonymous, paper survey elicited information from participants regarding demographic data, formal training on the use of the firearm, how the firearm was acquired, potential child access, knowledge of others injured by a firearm, whether the firearm was stored unlocked, factors motivating the surrender of the firearm, and other factors. Survey results were entered into a composite database and analyzed for differences in location, race, sex, and other factors. Participants (n = 301) were predominantly male (73.5%), white (80.9%), and older than 55 years (59.0%). They lived an average of 19.0 miles from the event by zip codes and had an average median household income of $65,731. More than half (54.5%) did not purchase the firearm, acquiring it through inheritance, gift, or random find. Most (74.8%) had previous firearms training and were relinquishing for safety reasons (68.3%). Those relinquishing firearms for safety reasons were less likely to have purchased the firearm (odds ratio [OR], 2.46, p <0.05), less likely to have any formal training (OR, 5.92; p < 0.01), and less likely to keep the firearm locked (OR, 3.50; p < 0.01). Women were less likely to have purchased the firearm (OR, 0.50; p < 0.05). Fifty-three percent of those turning in firearms reported having at least one more firearm at home; designated themselves to be white, compared with all other groups combined (OR, 2.55; p < 0.05); more likely to report locking the firearm (OR, 0.11; p < 0.001); more

  8. Should gun safety be taught in schools? Perspectives of teachers.

    PubMed

    Obeng, Cecilia

    2010-08-01

    Gun-related injuries and deaths among children occur at disproportionately high rates in the United States. Children who live in homes with guns are the most likely victims. This study describes teachers' views on whether gun safety should be taught to children in the preschool and elementary years. A total of 150 survey questionnaires were distributed to public and private school teachers in preschools and elementary schools in 2 counties of a Midwestern state. In total, 62% of the 102 respondents indicated that they favored the teaching of gun safety, while 13% disapproved and 25% had no opinion. Overall, 28.4% of the respondents supported the teaching of gun safety in grades pre-K (pre-kindergarten) through first grade. About 54% indicated that police or trained military personnel should do the teaching of this subject in schools, while 6.9% suggested that teachers should do the teaching. With a majority of the teachers in favor of teaching gun safety in the schools, a larger study should be conducted that explores the introduction of gun safety into the curriculum in preschool through grade 6. Such a study should evaluate the efficacy of teaching gun safety as a measure to prevent gun violence and injuries involving guns.

  9. In-state and interstate associations between gun shows and firearm deaths and injuries: A quasi-experimental study

    PubMed Central

    Matthay, Ellicott C.; Galin, Jessica; Rudolph, Kara E.; Farkas, Kriszta; Wintemute, Garen; Ahern, Jennifer

    2018-01-01

    Background Gun shows are an important source of firearms, but no adequately powered studies have examined whether these events are associated with increases in firearm injuries. Objective To determine whether gun shows are associated with short-term increases in locally occurring firearm injuries and whether this association differs by the state in which the gun show occurs. Design Quasi-experimental. Setting California. Study Population Individuals in California within driving distance of gun shows. Measurements Gun shows in California and Nevada between 2005 and 2013 (n = 915 shows) and rates of firearm-related deaths, emergency department visits, and inpatient hospitalizations in California. Results Compared to the two weeks before gun shows occurred, post-show firearm injury rates remained stable in regions near California gun shows but increased from 0.67 (95% CI, 0.55 to 0.80) to 1.14 (95% CI, 0.97 to 1.30) per 100,000 in regions near Nevada shows. After adjustment for seasonality and clustering, California shows were not associated with increases in local firearm injuries (RR, 0.99 [95% CI, 0.97 to 1.02]), but Nevada shows were associated with increases in injuries occurring in California (RR, 1.69 [95% CI, 1.16 to 2.45]). The pre-post difference was significantly higher for Nevada shows compared to California shows (Ratio of RRs, 1.70 [95% CI, 1.17 to 2.47]). The Nevada association was driven by significant increases in interpersonal violence firearm injuries (RR, 2.23 [95% CI, 1.01 to 4.89), but corresponded to a small increase in absolute numbers. Non-firearm injuries served as a negative control and were not associated with California or Nevada gun shows. Results were robust to sensitivity analyses. Limitation We only examined firearm injuries in California, and gun show occurrence was not randomized. Conclusion Gun shows occurring in Nevada, but not California, are associated with local, short-term increases in firearm injuries in California. Differing

  10. Note: design and development of improved indirectly heated cathode based strip electron gun.

    PubMed

    Maiti, Namita; Bade, Abhijeet; Tembhare, G U; Patil, D S; Dasgupta, K

    2015-02-01

    An improved design of indirectly heated solid cathode based electron gun (200 kW, 45 kV, 270° bent strip type electron gun) has been presented. The solid cathode is made of thoriated tungsten, which acts as an improved source of electron at lower temperature. So, high power operation is possible without affecting structural integrity of the electron gun. The design issues are addressed based on the uniformity of temperature on the solid cathode and the single long filament based design. The design approach consists of simulation followed by extensive experimentation. In the design, the effort has been put to tailor the non-uniformity of the heat flux from the filament to the solid cathode to obtain better uniformity of temperature on the solid cathode. Trial beam experiments have been carried out and it is seen that the modified design achieves one to one correspondence of the solid cathode length and the electron beam length.

  11. Note: Design and development of improved indirectly heated cathode based strip electron gun

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Maiti, Namita; Patil, D. S.; Dasgupta, K.

    An improved design of indirectly heated solid cathode based electron gun (200 kW, 45 kV, 270° bent strip type electron gun) has been presented. The solid cathode is made of thoriated tungsten, which acts as an improved source of electron at lower temperature. So, high power operation is possible without affecting structural integrity of the electron gun. The design issues are addressed based on the uniformity of temperature on the solid cathode and the single long filament based design. The design approach consists of simulation followed by extensive experimentation. In the design, the effort has been put to tailor themore » non-uniformity of the heat flux from the filament to the solid cathode to obtain better uniformity of temperature on the solid cathode. Trial beam experiments have been carried out and it is seen that the modified design achieves one to one correspondence of the solid cathode length and the electron beam length.« less

  12. High current polarized electron source for future eRHIC

    NASA Astrophysics Data System (ADS)

    Wang, Erdong

    2018-05-01

    The high current and high bunch charge polarized electron source is essential for cost reduction of Linac-Ring (L-R) eRHIC. In the baseline design, electron beam from multiple guns (probably 4-8) will be combined using deflection plates or accumulate ring. Each gun aims to deliver electron beam with 10 mA average current and 5.3 nC bunch charge. With total 50 mA and 5.3 nC electron beam, this beam combining design could use for generating positron too. The gun has been designed, fabricated and expected to start commissioning by the mid of this year. In this paper, we will present the DC gun design parameters and beam combine schemes. Also, we will describe the details of gun design and the strategies to demonstrate high current high charge polarized electron beam from this source.

  13. Engineering design of the PLX- α coaxial gun

    NASA Astrophysics Data System (ADS)

    Cruz, Edward; Brockington, Samuel; Case, Andrew; Luna, Marco; Witherspoon, Douglas; Langendorf, Samuel

    2016-10-01

    We describe the engineering and technical aspects of the coaxial gun designed for the 60-gun scaling study of spherically imploding plasma liners as a standoff driver for plasma-jet-driven magneto-inertial fusion. Each coaxial gun incorporates a fast, dense gas injection and triggering system, a compact low-weight pfn with integral sparkgap switching, and a contoured gap designed to suppress the blow-by instability. Alpha1 and Alpha2 guns are compared, with emphasis on the improvements on Alpha2, which include a faster more robust gas valve, an improved electrode contour, a custom 600- μF, 5-kV pfn, and a set of six inline sparkgap switches operated in parallel. The switch and pfn configurations are mounted directly to the back of the gun, and are designed to reduce inductance, cost, and complexity, maximize efficiency and system reliability, and ensure symmetric current flow. We will provide a detailed overview of the design choices made for the PLX- α coaxial gun. This work supported by the ARPA-E ALPHA Program.

  14. Analysis of magnetically immersed electron guns with non-adiabatic fields

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pikin, Alexander; Alessi, James G.; Beebe, Edward N.

    Electron diode guns, which have strongly varying magnetic or electric fields in a cathode-anode gap, were investigated in order to generate laminar electron beams with high current density using magnetically immersed guns. By creating a strongly varying radial electric field in a cathode-anode gap of the electron gun, it was demonstrated that the optical properties of the gun can be significantly altered, which allows the generation of a laminar, high-current electron beam with relatively low magnetic field on the cathode. The relatively high magnetic compression of the electron beam achieved by this method is important for producing electron beams withmore » high current density. A similar result can be obtained by inducing a strong variation of the magnetic field in a cathode-anode gap. It was observed that creating a dip in the axial magnetic field in the cathode-anode gap of an adiabatic electron gun has an optical effect similar to guns with strong variation of radial electric field. By analyzing the electron trajectories angles and presenting the results in a gun performance map different geometries of magnetically immersed electron guns with non-adiabatic fields are compared with each other and with a more traditional adiabatic electron gun. Some advantages and limitations of guns with non-adiabatic fields are outlined. In conclusion, the tests results of non-adiabatic electron gun with modified magnetic field are presented.« less

  15. Analysis of magnetically immersed electron guns with non-adiabatic fields

    DOE PAGES

    Pikin, Alexander; Alessi, James G.; Beebe, Edward N.; ...

    2016-11-08

    Electron diode guns, which have strongly varying magnetic or electric fields in a cathode-anode gap, were investigated in order to generate laminar electron beams with high current density using magnetically immersed guns. By creating a strongly varying radial electric field in a cathode-anode gap of the electron gun, it was demonstrated that the optical properties of the gun can be significantly altered, which allows the generation of a laminar, high-current electron beam with relatively low magnetic field on the cathode. The relatively high magnetic compression of the electron beam achieved by this method is important for producing electron beams withmore » high current density. A similar result can be obtained by inducing a strong variation of the magnetic field in a cathode-anode gap. It was observed that creating a dip in the axial magnetic field in the cathode-anode gap of an adiabatic electron gun has an optical effect similar to guns with strong variation of radial electric field. By analyzing the electron trajectories angles and presenting the results in a gun performance map different geometries of magnetically immersed electron guns with non-adiabatic fields are compared with each other and with a more traditional adiabatic electron gun. Some advantages and limitations of guns with non-adiabatic fields are outlined. In conclusion, the tests results of non-adiabatic electron gun with modified magnetic field are presented.« less

  16. Model for intensity calculation in electron guns

    NASA Astrophysics Data System (ADS)

    Doyen, O.; De Conto, J. M.; Garnier, J. P.; Lefort, M.; Richard, N.

    2007-04-01

    The calculation of the current in an electron gun structure is one of the main investigations involved in the electron gun physics understanding. In particular, various simulation codes exist but often present some important discrepancies with experiments. Moreover, those differences cannot be reduced because of the lack of physical information in these codes. We present a simple physical three-dimensional model, valid for all kinds of gun geometries. This model presents a better precision than all the other simulation codes and models encountered and allows the real understanding of the electron gun physics. It is based only on the calculation of the Laplace electric field at the cathode, the use of the classical Child-Langmuir's current density, and a geometrical correction to this law. Finally, the intensity versus voltage characteristic curve can be precisely described with only a few physical parameters. Indeed, we have showed that only the shape of the electric field at the cathode without beam, and a distance of an equivalent infinite planar diode gap, govern mainly the electron gun current generation.

  17. Utility of indices of gun availability in the community

    PubMed Central

    Shenassa, Edmond D; Daskalakis, Constantine; Buka, Stephen L

    2006-01-01

    Objective To estimate the degree to which the proportion of homicides and suicides committed with a gun is associated with reported availability of firearms across Chicago neighbourhoods. Methods Data were collected as part of the Project on Human Development in Chicago Neighborhoods (PHDCN), a combined neighbourhood and individual level study of the city of Chicago. The study used data from 837 PHDCN participants between the ages of 17 and 22, residing in 170 different neighbourhoods. Gun availability was measured via participant reports on whether they had carried a gun and whether they perceived gun access to be easy in their community. Data on suicides and homicides were obtained from the Chicago Department of Health. Results A 10% change in the proportion of homicides committed by a gun in a neighbourhood was associated with a 20% increase in both the odds of reported gun access and reported gun carrying (p = 0.002 and 0.048, respectively). The proportion of firearm related suicides was not associated with either of those self reported measures. Conclusions The proportion of firearm related homicides, but not the proportion of firearm related suicides, is a useful predictor of gun availability across small areas such as neighbourhoods. PMID:16401610

  18. HVAC SYSTEMS AS EMISSION SOURCES AFFECTING INDOOR AIR QUALITY: A CRITICAL REVIEW

    EPA Science Inventory

    The study evaluates heating, ventilating, and air-conditioning (HVAC) systems as contaminant emission sources that affect indoor air quality (IAQ). Various literature sources and methods for characterizing HVAC emission sources are reviewed. Available methods include in situ test...

  19. Experiments and Demonstrations with Soldering Guns.

    ERIC Educational Resources Information Center

    Henry, Dennis C.; Danielson, Sarah A.

    1993-01-01

    Discusses the essential electrical characteristics of a particular model of soldering gun. Presents four classroom demonstrations that utilize the soldering gun to test the following geometrics of wire loops as electromagnets: (1) the original tip; (2) a single circular loop; (3) a Helmholtz coil; and (4) the solenoid. (MDH)

  20. Global Power Requires a Global, Persistent Air-to-Air Capability

    DTIC Science & Technology

    2010-01-01

    anywhere on the high seas, and in most coastal waters as well, and sink them if necessary by using guns, missiles, or tor- pedoes . Current Air Force...apparently a number of so-far-undisclosed challenges remain, perhaps including the air refuel- ing of an RPA and maintaining the data link with it in...will remain relatively short- range systems.31 With regard to the data link , a remote pi- lot flies the Predator—our primary opera- tional, fighter-sized

  1. Simulations of Gaussian electron guns for RHIC electron lens

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pikin, A.

    Simulations of two versions of the electron gun for RHIC electron lens are presented. The electron guns have to generate an electron beam with Gaussian radial profile of the electron beam density. To achieve the Gaussian electron emission profile on the cathode we used a combination of the gun electrodes and shaping of the cathode surface. Dependence of electron gun performance parameters on the geometry of electrodes and the margins for electrodes positioning are presented.

  2. Gun Carrying by High School Students in Boston, MA: Does Overestimation of Peer Gun Carrying Matter?

    ERIC Educational Resources Information Center

    Hemenway, David; Vriniotis, Mary; Johnson, Renee M.; Miller, Matthew; Azrael, Deborah

    2011-01-01

    This paper investigates: (1) whether high school students overestimate gun carrying by their peers, and (2) whether those students who overestimate peer gun carrying are more likely to carry firearms. Data come from a randomly sampled survey conducted in 2008 of over 1700 high school students in Boston, MA. Over 5% of students reported carrying a…

  3. Research on vibration characteristics of gun barrel based on contact model

    NASA Astrophysics Data System (ADS)

    Zhao, Yang; Zhou, Qizheng; Yue, Pengfei

    2017-04-01

    In order to study vibration characteristics of the gun barrel under the action of moving projectile, the gun barrel is simplified to cross sectional cantilever beam such as Euler. Considering contact conditions of inertia effect and projectile with the gun barrel, the equation of lateral vibration of the gun barrel is established under the projectile-gun coupling effect; the modal analysis method is used to give the analytic solutions of equation series. The effect of the motion parameters the projectile on the vibration of gun barrel is discussed, and characteristics of vibration of gun barrel are further studied under two conditions of repeating and projectile with mass eccentricity. The research results show that reasonable control of the acceleration of the projectile in the gun bore, and reduction of projectile mass eccentricity can help reduce the muzzle vibration at the gun firing. The research results can provide reference for overall design of the gun, and the modeling and analysis method used in the paper can be promoted for the solution of vibration of other related projects under the moving excitation.

  4. The PLX- α Plasma Guns: Progress and Plans

    NASA Astrophysics Data System (ADS)

    Witherspoon, F. D.; Brockington, S.; Case, A.; Cruz, E.; Luna, M.; Thio, Y. C. Francis; LANL PLX-α Team

    2017-10-01

    The ALPHA coaxial plasma guns are being developed to support a 60-gun scaling study of spherically imploding plasma liners as a standoff driver for plasma-jet-driven magneto-inertial fusion (PJMIF). Seven complete guns have been delivered to LANL with 6 guns currently undergoing simultaneous test firings on PLX. The guns are designed to operate over a range of parameters: 0.5-5.0 mg of Ar, Ne, N2, Kr, and Xe; 20-60 km/s; 2 × 1016 cm-3 muzzle density; and up to 7.5 kJ stored energy per gun. Each coaxial gun incorporates a fast dense gas injection and triggering system, a compact low-weight pfn with integral sparkgap switching, and a contoured coaxial gap to suppress the blow-by instability. Optimizing parameter scans performed at HyperV have achieved : 4 mg at >50 km/s and length of 10 cm. Peak axial density 30 cm from the muzzle is 2 ×1016 cm-3. We will provide an overview of the experimental results, along with plans for further improvements in reliability, maintainability, fabricability, and plasma jet performance, with the latter focused on further improvements in the fast gas valve and the ignitors. This work supported by the ARPA-E ALPHA Program under contract DE-AR0000566 and Strong Atomics, LLC.

  5. HVAC SYSTEMS AS EMISSION SOURCES AFFECTING INDOOR AIR QUALITY: A CRITICAL REVIEW

    EPA Science Inventory

    The paper discusses results of an evaluation of literature on heating, ventilating, and air-conditioning (HVAC) systems as contaminant emission sources that affect indoor air quality (IAQ). The various literature sources and methods for characterizing HVAC emission sources are re...

  6. Quantum efficiency temporal response and lifetime of a GaAs cathode in SRF electron gun

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, E.; Ben-Zvi, I.; Kewisch, J.

    2010-05-23

    RF electron guns with a strained super lattice GaAs cathode can generate polarized electron beam of higher brightness and lower emittance than do DC guns, due to their higher field gradient at the cathode's surface. In a normal conducting RF gun, the extremely high vaccum required by these cathodes can not be met. We report on an experiment with a superconducting SRF gun, which can maintain a vacuum of nearly 10-12 torr because of cryo-pumping at the temperature of 4.2K. With conventional activation, we obtained a QE of 3% at 532 nm, with lifetime of nearly 3 days in themore » preparation chamber. We plan to use this cathode in a 1.3 GHz 1/2 cell SRF gun to study its performance. In addition, we studied the multipacting at the location of cathode. A new model based on the Forkker-Planck equation which can estimate the bunch length of the electron beam is discussed in this paper. Future particle accelerators such as eRHIC and ILC require high brightness, high current polarized electrons Recently, using a superlattice crystal, the maximum polarization of 95% was reached. Activation with Cs,O lowers the electron affinity and makes it energetically possible for all the electrons excited in to the conduction band and reach the surface to escape into the vacuum. Presently the polarized electron sources are based on DC gun, such as that at the CEBAF at Jlab. In these devices, the life time of the cathode is extended due to the reduced back bombardment in their UHV conditions. However, the low accelerating gradient of the DC guns lead to poor longitudinal emittance. The higher accelerating gradient of the RF gun generates low emittance beams. Superconducting RF guns combine the excellent vacuum conditions of the DC guns with the higher accelerating gradients of the RF guns and provide potentially a long lived cathode with very low transverse and longitudinal emittance. In our work at BNL, we successfully activated the GaAs. The quantum efficient is 3% at 532 nm and is

  7. Development of plasma cathode electron guns

    NASA Astrophysics Data System (ADS)

    Oks, Efim M.; Schanin, Peter M.

    1999-05-01

    The status of experimental research and ongoing development of plasma cathode electron guns in recent years is reviewed, including some novel upgrades and applications to various technological fields. The attractiveness of this kind of e-gun is due to its capability of creating high current, broad or focused beams, both in pulsed and steady-state modes of operation. An important characteristic of the plasma cathode electron gun is the absence of a thermionic cathode, a feature which leads to long lifetime and reliable operation even in the presence of aggressive background gas media and at fore-vacuum gas pressure ranges such as achieved by mechanical pumps. Depending on the required beam parameters, different kinds of plasma discharge systems can be used in plasma cathode electron guns, such as vacuum arcs, constricted gaseous arcs, hollow cathode glows, and two kinds of discharges in crossed E×B fields: Penning and magnetron. At the present time, plasma cathode electron guns provide beams with transverse dimension from fractional millimeter up to about one meter, beam current from microamperes to kiloamperes, beam current density up to about 100 A/cm2, pulse duration from nanoseconds to dc, and electron energy from several keV to hundreds of keV. Applications include electron beam melting and welding, surface treatment, plasma chemistry, radiation technologies, laser pumping, microwave generation, and more.

  8. Portable air pollution control equipment for the control of toxic particulate emissions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chaurushia, A.; Odabashian, S.; Busch, E.

    1997-12-31

    Chromium VI (Cr VI) has been identified by the environmental regulatory agencies as a potent carcinogen among eleven heavy metals. A threshold level of 0.0001 lb/year for Cr VI emissions has been established by the California Air Resources Board for reporting under Assembly Bill 2588. A need for an innovative control technology to reduce fugitive emissions of Cr VI was identified during the Air Toxic Emissions Reduction Program at Northrop Grumman Military Aircraft Systems Division (NGMASD). NGMASD operates an aircraft assembly facility in El Segundo, CA. Nearly all of the aircraft components are coated with a protective coating (primer) priormore » to assembly. The primer has Cr VI as a component for its excellent corrosion resistance property. The complex assembly process requires fasteners which also need primer coating. Therefore, NGMASD utilizes High Volume Low Pressure (HVLP) guns for the touch-up spray coating operations. During the touch-up spray coating operations, Cr VI particles are atomized and transferred to the aircraft surface. The South Coast Air Quality Management District (SCAQMD) has determined that the HVLP gun transfers 65% of the paint particles onto the substrate and the remaining 35% are emitted as an overspray if air pollution controls are not applied. NGMASD has developed the Portable Air Pollution Control Equipment (PAPCE) to capture and control the overspray in order to reduce fugitive Cr VI emissions from the touch-up spray coating operations. A source test was performed per SCAQMD guidelines and the final report has been approved by the SCAQMD.« less

  9. Optimization of a two stage light gas gun. M.S. Thesis

    NASA Technical Reports Server (NTRS)

    Rynearson, R. J.; Rand, J. L.

    1972-01-01

    Performance characteristics of the Texas A&M University light gas gun are presented along with a review of basic gun theory and popular prediction methods. A computer routine based on the simple isentropic compression method is discussed. Results from over 60 test shots are given which demonstrate an increase in gun muzzle velocity from 9.100 ft/sec. to 19,000 ft/sec. The data gathered indicated the Texas A&M light gas gun more closely resembles an isentropic compression gun rather than a shock compression gun.

  10. Accidental Bolt Gun Injury to Femur - A Case Report.

    PubMed

    Kattimani, Ravi Prasad; Shetty, Sanath; Mirza, Humayun

    2016-01-01

    Bolt gun or slaughterer's guns are used in meat industry for "humane killing" of animals. Injuries caused by bolt gun are rare, reported exclusively from central European countries. We report a case of 28 year old male, who accidentally shot himself with a bolt gun to his right thigh. A 28 years old male presented to our Accident and Emergency department after accidental injury to his right thigh with bolt gun. He had an entry wound measuring 2 cm in length and 1 cm in breadth over anterior aspect of lower one third of thigh at lower and sustained Grade II compound fracture of right femur shaft at distal one third. The wound was treated with multiple debridements, negative pressure wound therapy and intravenous antibiotics based on culture and sensitivity. Bolt gun or slaughterer's guns are weapons used in meat industry for slaughtering animals. Wounds inflicted by bolt guns have specific morphological feature, distinctive from wounds made by other kinds of hand firearms. Most of the time wound will be infected at presentation. Lesions caused by these weapons are likely to have a more serious character than is to be expected from the size of the entrance wound. The mainstay of treatment is liberal wound exploration, multiple debridement's and intra venous antibiotics based on culture reports to treat infection and prevent morbidity.

  11. Characteristics of a gun exchange program, and an assessment of potential benefits

    PubMed Central

    Romero, M.; Wintemute, G.; Vernick, J.

    1998-01-01

    Objectives—To describe a gun exchange program and assess potential benefits for participants and host communities. Methods—Mail survey of participants in a Sacramento, California gun exchange program, August 1993; the response rate was 79%. Comparative data were obtained from nationwide polls of gun owners. Results—Most (62%) respondents were men; 40% were more than 55 years old; none was less than 25. Concern that children might find and use the gun was the most frequently cited reason for participating (46% of respondents). Of 141 firearms exchanged, 72% were handguns; 23% of respondents indicated that the guns they turned in were not in working order. Of respondents who owned a gun at the time of the program (rather than those who owned no guns and turned in a gun owned by someone else), 41% owned no guns after participating; the prevalence of handgun ownership declined from 79% to 32%. Those who continued to own guns were as likely as gun owners nationwide to keep a gun loaded in the house (odds ratio (OR) 0.9, 95% confidence interval (CI) 0.4 to 1.7) or to carry a gun with them (OR 1.5, 95% CI 0.6 to 3.8). Conclusions—Gun exchange programs may reduce risk for firearm violence among some participants, but a number of factors limit their overall benefits to host communities. PMID:9788092

  12. In-State and Interstate Associations Between Gun Shows and Firearm Deaths and Injuries: A Quasi-experimental Study.

    PubMed

    Matthay, Ellicott C; Galin, Jessica; Rudolph, Kara E; Farkas, Kriszta; Wintemute, Garen J; Ahern, Jennifer

    2017-12-19

    Gun shows are an important source of firearms, but no adequately powered studies have examined whether they are associated with increases in firearm injuries. To determine whether gun shows are associated with short-term increases in local firearm injuries and whether this association differs by the state in which the gun show is held. Quasi-experimental. California. Persons in California within driving distance of gun shows. Gun shows in California and Nevada between 2005 and 2013 (n = 915 shows) and rates of firearm-related deaths, emergency department visits, and inpatient hospitalizations in California. Compared with the 2 weeks before, postshow firearm injury rates remained stable in regions near California gun shows but increased from 0.67 injuries (95% CI, 0.55 to 0.80 injuries) to 1.14 injuries (CI, 0.97 to 1.30 injuries) per 100 000 persons in regions near Nevada shows. After adjustment for seasonality and clustering, California shows were not associated with increases in local firearm injuries (rate ratio [RR], 0.99 [CI, 0.97 to 1.02]) but Nevada shows were associated with increased injuries in California (RR, 1.69 [CI, 1.16 to 2.45]). The pre-post difference was significantly higher for Nevada shows than California shows (ratio of RRs, 1.70 [CI, 1.17 to 2.47]). The Nevada association was driven by significant increases in firearm injuries from interpersonal violence (RR, 2.23 [CI, 1.01 to 4.89]) but corresponded to a small increase in absolute numbers. Nonfirearm injuries served as a negative control and were not associated with California or Nevada gun shows. Results were robust to sensitivity analyses. Firearm injuries were examined only in California, and gun show occurrence was not randomized. Gun shows in Nevada, but not California, were associated with local, short-term increases in firearm injuries in California. Differing associations for California versus Nevada gun shows may be due to California's stricter firearm regulations. National

  13. Gun violence in Americans' social network during their lifetime.

    PubMed

    Kalesan, Bindu; Weinberg, Janice; Galea, Sandro

    2016-12-01

    The overall burden of gun violence death and injury in the US is now well understood. However, no study has shown the extent to which gun violence is associated with the individual lives of Americans. We used fatal and non-fatal gun injury rates in 2013 from Centers for Disease Control and Prevention's Web-based Injury Statistics Query and Reporting System (WISQARS) and generally accepted estimates about the size of an American's social network to determine the likelihood that any given person will know someone in their personal social network who is a victim of gun violence during their lifetime. We derived estimates in the overall population and among racial/ethnic groups and by gun-injury intent. The likelihood of knowing a gun violence victim within any given personal network over a lifetime is 99.85% (99.8% to 99.9%). The likelihood among non-Hispanic white, black, Hispanic and other race Americans were 97.1%, 99.9%, 99.5% and 88.9% respectively. Nearly all Americans of all racial/ethnic groups are likely to know a victim of gun violence in their social network during their lifetime. Copyright © 2016 Elsevier Inc. All rights reserved.

  14. Modeling electron beam parameters and plasma interface position in an anode plasma electron gun with hydrogen atmosphere

    NASA Astrophysics Data System (ADS)

    Krauze, A.; Virbulis, J.; Kravtsov, A.

    2018-05-01

    A beam glow discharge based electron gun can be applied as heater for silicon crystal growth systems in which silicon rods are pulled from melt. Impacts of high-energy charged particles cause wear and tear of the gun and generate an additional source of silicon contamination. A steady-state model for electron beam formation has been developed to model the electron gun and optimize its design. Description of the model and first simulation results are presented. It has been shown that the model can simulate dimensions of particle impact areas on the cathode and anode, but further improvements of the model are needed to correctly simulate electron trajectory distribution in the beam and the beam current dependence on the applied gas pressure.

  15. NPS Gas Gun for Planar Impact Studies

    NASA Astrophysics Data System (ADS)

    Cheong Ho, Chien; Hixson, Robert

    2009-11-01

    The Naval Postgraduate School (NPS) commissioned a Gas Gun for shock wave studies on 9^th October 2009, by performing the first experiment. The Gas Gun is the key element of NPS Shock Wave Research Program within the Physics Department, where well-characterized planar impacts are essential for obtaining high quality data, to characterize a solid material. This first experiment was very successful, and returned key data on the quality of the impact conditions created. The Gas Gun is designed by SANDIA NATIONAL LABORATORIES, and the NPS spent twelve months fabricating the components of the Gas Gun and six months assembling the Gas Gun. Three inch projectile are launched at velocities up to 0.5 km/s, creating high pressure and temperature states that can be used to characterize the fundamental response of relevant materials to dynamic loading. The projectile is launched from a `wrap around' gas breech where helium gas is pressurized to relatively low pressure. This gas is used to accelerate the projectile down a 3m barrel. Upon impact, the speed of the projectile and the flatness of the impact is measured, via a stepped circular pin array circuit. The next stage of development for the Gas Gun is to integrate a Velocity Interferometer System for Any Reflector (VISAR). The VISAR sees all the waves that flow through the target plate as a result of the impact. This is a key diagnostic for determining material properties under dynamic loading conditions.

  16. Handgun waiting periods reduce gun deaths

    PubMed Central

    Luca, Michael; Malhotra, Deepak

    2017-01-01

    Handgun waiting periods are laws that impose a delay between the initiation of a purchase and final acquisition of a firearm. We show that waiting periods, which create a “cooling off” period among buyers, significantly reduce the incidence of gun violence. We estimate the impact of waiting periods on gun deaths, exploiting all changes to state-level policies in the Unites States since 1970. We find that waiting periods reduce gun homicides by roughly 17%. We provide further support for the causal impact of waiting periods on homicides by exploiting a natural experiment resulting from a federal law in 1994 that imposed a temporary waiting period on a subset of states. PMID:29078268

  17. Law enforcement officers' opinions about gun locks: anchors on life jackets?

    PubMed Central

    Coyne-Beasley, T; Johnson, R

    2001-01-01

    Objectives—One way law enforcement officers support firearm safety is by promoting the use of gun locks. This investigation examined law enforcement officers' willingness to use gun locks on their own guns, as well as their opinions regarding gun locks in general. Setting—Law enforcement officers from an urban agency in the southern region of the United States. Methods—Free keyed cable gun locks were distributed to all law enforcement officers in one agency who wanted one, and then an anonymous questionnaire survey was conducted about their subsequent use of, and attitudes toward, these devices. Results—About half of the 207 officers collected gun locks (n=103). Nearly three quarters (73%) completed and returned the questionnaire. Two thirds reported that they were not using the gun lock they collected (65%), and over half disagreed that gun lock use should be required (56%). Very few cited any actual or potential technical problems with the device. An important reason given for non-use of gun locks related to being able to access the weapon quickly in case of an emergency. Conclusions—The findings highlight the need for further investigation into law enforcement officers' attitudes toward gun locks, the degree to which their attitudes affect their firearm safety counseling, and the need to develop a gun safety device that can be disengaged quickly. PMID:11565984

  18. ONEGUN: an interior ballistics code for closed breech guns

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Reis, G.E.

    1982-07-01

    This program computes the gun and projectile motion and the gas thermodynamic properties (the internal ballistics) of a closed breech gun. Heat losses and friction losses are taken into account. A dual grain charge can be used. The inputs required are the usual propellant characteristics (density, impetus, gamma, burn rate coefficient and exponent, grain geometry, covolume and isochoric flame temperature). The gun characteristics (chamber volume and length, rifle twist rate, bore diameter, gun weight and start pressure) and the projectile characteristics (projectile weight, radius of gyration and start pressure). The output consists of the motion (displacement, velocity, and acceleration) ofmore » both the projectile and the recoiling gun and the gas pressures and temperature, all as a function of time.« less

  19. Youth Homicide and Guns. Firearm Facts.

    ERIC Educational Resources Information Center

    Duker, Laurie, Ed.

    Young Americans are killed with guns at rates far higher than young people in other countries and than older Americans, with young, urban African-American males being most at risk. This fact sheet presents data on gun-related homicides among teenagers in the United States. The high rate of youth homicide in the United States is unique in the…

  20. RF Guns for Generation of Polarized Electron Beams

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Clendenin, J.E.; Brachmann, A.; Dowell, D.H.

    2005-11-09

    Several accelerators, including the SLC, JLAB, Mainz, Bates/MIT, and Bonn have successfully operated for medium and high energy physics experiments using polarized electron beams generated by dc-biased guns employing GaAs photocathodes. Since these guns have all used a bias on the order of 100 kV, the longitudinal emittance of the extracted bunch is rather poor. Downstream rf bunching systems increase the transverse emittance. An rf gun with a GaAs photocathode would eliminate the need for separate rf bunchers, resulting in a simpler injection system. In addition, the thermal emittance of GaAs-type cathodes is significantly lower than for other photocathode materials.more » The environmental requirements for operating activated GaAs photocathodes cannot be met by rf guns as currently designed and operated. These requirements, including limits on vacuum and electron back bombardment, are discussed in some detail. Modifications to actual and proposed rf gun designs that would allow these requirements to be met are presented.« less

  1. A practical example aiding understanding momentum in 1D: the water gun experiment

    NASA Astrophysics Data System (ADS)

    MacLeod, Katarin

    2007-09-01

    The law of conservation of momentum is one that students often have difficulties understanding. This experiment allows students to use childhood toys to examine and calculate the muzzle velocity of their favourite water gun by using an air track, a spark timer or data logger and the law of conservation of momentum in a one-dimensional case, a modification of the standard ballistic pendulum laboratory experiment (1990 Physics 100 Lab Manual St Francis Xavier University).

  2. Specifying the role of exposure to violence and violent behavior on initiation of gun carrying: a longitudinal test of three models of youth gun carrying.

    PubMed

    Spano, Richard; Pridemore, William Alex; Bolland, John

    2012-01-01

    Two waves of longitudinal data from 1,049 African American youth living in extreme poverty are used to examine the impact of exposure to violence (Time 1) and violent behavior (Time 1) on first time gun carrying (Time 2). Multivariate logistic regression results indicate that (a) violent behavior (Time 1) increased the likelihood of initiation of gun carrying (Time 2) by 76% after controlling for exposure to violence at Time 1, which is consistent with the stepping stone model of youth gun carrying, and (b) youth who were both exposed to violence at Time 1 and engaged in violent behavior at Time 1 were more than 2.5 times more likely to initiate gun carrying at Time 2 compared to youth who had neither of these characteristics, which supports the cumulative risk model of youth gun carrying. The authors discuss the implications of these findings in clarifying the role of violence in the community on youth gun carrying and the primary prevention of youth gun violence.

  3. Engineering design of the PLX- α coaxial gun

    NASA Astrophysics Data System (ADS)

    Cruz, E.; Brockington, S.; Case, A.; Luna, M.; Witherspoon, F. D.; Thio, Y. C. Francis; PLX-α Team

    2017-10-01

    We describe the engineering and technical improvements, as well as provide a detailed overview of the design choices, of the latest PLX- α coaxial gun designed for the 60-gun scaling study of spherically imploding plasma liners as a standoff driver for plasma-jet-driven magneto-inertial fusion. Each coaxial gun incorporates a fast, dense gas injection and triggering system, a compact low-weight pfn with integral sparkgap switching, and a contoured gap designed to suppress the blow-by instability. The evolution of the latest Alpha gun is presented with emphasis on its upgraded performance. Changes include a faster more robust gas valve, better-quality ceramic insulator material and enhancements to overall design layout. These changes result in a gun with increased repeatability, reduced potential failure modes, improved fault tolerance and better than expected efficiency. A custom 600- μF, 5-kV pfn and a set of six inline sparkgap switches operated in parallel are mounted directly to the back of the gun, and are designed to reduce inductance, cost, and complexity, maximize efficiency and system reliability, and ensure symmetric current flow. This work supported by the ARPA-E ALPHA Program under contract DE-AR0000566 and Strong Atomics, LLC.

  4. Investigations and Applications of Field- and Photo-emitted Electron Beams from a Radio Frequency Gun

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Panuganti, SriHarsha

    Production of quality electron bunches using e cient ways of generation is a crucial aspect of accelerator technology. Radio frequency electron guns are widely used to generate and rapidly accelerate electron beams to relativistic energies. In the current work, we primarily study the charge generation processes of photoemission and eld emission inside an RF gun installed at Fermilab's High Brightness Electron Source Laboratory (HBESL). Speci cally, we study and characterize second-order nonlinear photoemission from a Cesium Telluride (Cs 2Te) semiconductor photocathode, and eld emission from carbon based cathodes including diamond eld emission array (DFEA) and carbon nanotube (CNT) cathodes locatedmore » in the RF gun's cavity. Finally, we discuss the application experiments conducted at the facility to produce soft x-rays via inverse Compton scattering (ICS), and to generate uniformly lled ellipsoidal bunches and temporally shaped electron beams from the Cs 2Te photocathode.« less

  5. Spectrometer gun

    DOEpatents

    Waechter, David A.; Wolf, Michael A.; Umbarger, C. John

    1985-01-01

    A hand-holdable, battery-operated, microprocessor-based spectrometer gun includes a low-power matrix display and sufficient memory to permit both real-time observation and extended analysis of detected radiation pulses. Universality of the incorporated signal processing circuitry permits operation with various detectors having differing pulse detection and sensitivity parameters.

  6. Mass Shootings, Mental Illness, and Gun Control.

    PubMed

    Philpott-Jones, Sean

    2018-03-01

    In the wake of the Stoneman Douglas School shooting, Republican and Democratic leaders-like the American electorate they represent-remain sharply divided in their responses to gun violence. They are united in their condemnation of these mass shootings, but they disagree about whether stricter or looser gun control laws are the answer. Those on the right side of the political aisle suggest that the issue is one of mental illness rather than gun control. Conversely, those who are more liberal or progressive in their political learnings are quick to condemn attempts to reframe the issue of mass shootings as a mental health problem. Both sides are wrong. Mass shootings are indeed partially a mental health problem, albeit one poorly addressed by our current laws and policies. But the solution to mass shootings also needs to consider strategies that may reduce gun violence in general. © 2018 The Hastings Center.

  7. Design and development of a 40 kV pierce electron gun

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bhattacharjee, D.; Tiwari, R.; Jayaprakash, D., E-mail: dhruva.bhattacharjee@gmail.com

    A 40 kV electron gun is designed and developed using the Pierce configuration for the focusing electrode. Simulations were carried out using CST Particle Studio. The Gun is a thermionic type electron gun with indirect heating of the LaB6 cathode. The gun is capable of delivering a beam current of more than 500 mA at 40 kV with a beam size of less than 5 mm. The cathode assembly consists of cups and heat shields made out of Tantalum and Rhenium sheets. The cathode assembly and the electron gun was fabricated, assembled and tested on test bench for cathode conditioning,more » HV conditioning and beam characterization. This paper presents the gun design, particle simulations study, testing of the gun on test bench. (author)« less

  8. Modeling population exposures to outdoor sources of hazardous air pollutants.

    PubMed

    Ozkaynak, Halûk; Palma, Ted; Touma, Jawad S; Thurman, James

    2008-01-01

    Accurate assessment of human exposures is an important part of environmental health effects research. However, most air pollution epidemiology studies rely upon imperfect surrogates of personal exposures, such as information based on available central-site outdoor concentration monitoring or modeling data. In this paper, we examine the limitations of using outdoor concentration predictions instead of modeled personal exposures for over 30 gaseous and particulate hazardous air pollutants (HAPs) in the US. The analysis uses the results from an air quality dispersion model (the ASPEN or Assessment System for Population Exposure Nationwide model) and an inhalation exposure model (the HAPEM or Hazardous Air Pollutant Exposure Model, Version 5), applied by the US. Environmental protection Agency during the 1999 National Air Toxic Assessment (NATA) in the US. Our results show that the total predicted chronic exposure concentrations of outdoor HAPs from all sources are lower than the modeled ambient concentrations by about 20% on average for most gaseous HAPs and by about 60% on average for most particulate HAPs (mainly, due to the exclusion of indoor sources from our modeling analysis and lower infiltration of particles indoors). On the other hand, the HAPEM/ASPEN concentration ratio averages for onroad mobile source exposures were found to be greater than 1 (around 1.20) for most mobile-source related HAPs (e.g. 1, 3-butadiene, acetaldehyde, benzene, formaldehyde) reflecting the importance of near-roadway and commuting environments on personal exposures to HAPs. The distribution of the ratios of personal to ambient concentrations was found to be skewed for a number of the VOCs and reactive HAPs associated with major source emissions, indicating the importance of personal mobility factors. We conclude that the increase in personal exposures from the corresponding predicted ambient levels tends to occur near locations where there are either major emission sources of HAPs

  9. Handgun waiting periods reduce gun deaths.

    PubMed

    Luca, Michael; Malhotra, Deepak; Poliquin, Christopher

    2017-11-14

    Handgun waiting periods are laws that impose a delay between the initiation of a purchase and final acquisition of a firearm. We show that waiting periods, which create a "cooling off" period among buyers, significantly reduce the incidence of gun violence. We estimate the impact of waiting periods on gun deaths, exploiting all changes to state-level policies in the Unites States since 1970. We find that waiting periods reduce gun homicides by roughly 17%. We provide further support for the causal impact of waiting periods on homicides by exploiting a natural experiment resulting from a federal law in 1994 that imposed a temporary waiting period on a subset of states. Copyright © 2017 the Author(s). Published by PNAS.

  10. Unusual Case of Suicide With a Modified Trap Gun.

    PubMed

    Vadysinghe, Amal; Dassanayake, Prasanna; Wickramasinghe, Medhani

    2017-06-01

    Trap gun is an illegal, locally manufactured gun with a basic trip system used to hunt wild animals. The body of a 28-year-old man was found in the jungle in supine position with both legs apart. A trap gun was between the legs pointing toward the cranial side of the body. It had 2 free wires that were not connected together. There was no evidence of foul play.The body had a single-entry wound (2.5-cm diameter) in the anterior chest, with blackening, burning, and tattooing. Six metal particles and nylon clothing material were embedded into soft tissue. No exit wound was found. Toxicology analysis reported an alcohol level of 72 mg/dL. The cause of death was multiple shrapnel injury to the chest at close to intermediate range by a single discharge from a trap gun. Circumstance was concluded as suicide.Ballistic and firearm experts opined that an illegal, manually operated, battery-powered ignition device was used to ignite the gun powder. We report the first case of suicide by a modified trap gun in literature.

  11. Contoured-gap coaxial guns for imploding plasma liner experiments

    NASA Astrophysics Data System (ADS)

    Witherspoon, F. D.; Case, A.; Brockington, S.; Cassibry, J. T.; Hsu, S. C.

    2014-10-01

    Arrays of supersonic, high momentum flux plasma jets can be used as standoff compression drivers for generating spherically imploding plasma liners for driving magneto-inertial fusion, hence the name plasma-jet-driven MIF (PJMIF). HyperV developed linear plasma jets for the Plasma Liner Experiment (PLX) at LANL where two guns were successfully tested. Further development at HyperV resulted in achieving the PLX goal of 8000 μg at 50 km/s. Prior work on contoured-gap coaxial guns demonstrated an approach to control the blowby instability and achieved substantial performance improvements. For future plasma liner experiments we propose to use contoured-gap coaxial guns with small Minirailgun injectors. We will describe such a gun for a 60-gun plasma liner experiment. Discussion topics will include impurity control, plasma jet symmetry and topology (esp. related to uniformity and compactness), velocity capability, and techniques planned for achieving gun efficiency of >50% using tailored impedance matched pulse forming networks. Mach2 and UAH SPH code simulations will be included. Work supported by US DOE DE-FG02-05ER54810.

  12. National attitudes concerning gun carrying in the United States

    PubMed Central

    Hemenway, D; Azrael, D; Miller, M

    2001-01-01

    Objectives—To determine public attitudes in the United States concerning gun carrying. Setting—In the past 15 years, many state legislatures have passed laws making it easier for United States citizens to carry concealed firearms, not only on the street but into various locations, including churches and government buildings. Methods—National random digit dial telephone surveys conducted in 1996 and 1999 asked questions concerning the public's feelings of safety as more people in their community carry firearms, and whether, in the language of the question, respondents believe "regular" citizens should be allowed to carry guns into public or government buildings. Results—Americans feel less safe rather than more safe as more people in their community begin to carry guns. By margins of at least nine to one, Americans do not believe that "regular" citizens should be allowed to bring their guns into restaurants, college campuses, sports stadiums, bars, hospitals, or government buildings. Conclusions—The public believes that increased gun carrying by others reduces rather than increases their safety. Overwhelmingly, the public believes that in many venues gun carrying should be prohibited. PMID:11770652

  13. Spectrometer gun

    DOEpatents

    Waechter, D.A.; Wolf, M.A.; Umbarger, C.J.

    1981-11-03

    A hand-holdable, battery-operated, microprocessor-based spectrometer gun is described that includes a low-power matrix display and sufficient memory to permit both real-time observation and extended analysis of detected radiation pulses. Universality of the incorporated signal processing circuitry permits operation with various detectors having differing pulse detection and sensitivity parameters.

  14. Gunshot injuries due to celebratory gun shootings.

    PubMed

    Ozdemir, Mevci; Unlü, Ağahan

    2009-01-01

    Traditional shooting with guns often occurs and leads to unwanted gunshot injuries in areas where celebrations are held. Such injuries have been classified as celebratory gun shooting injury in the international disease classification system. An 8-year-old female patient presented with respiratory arrest. The heartbeats normalized upon cardiopulmonary resuscitation. On physical examination, the only pathological finding was a skin defect measuring 1 x 1 cm on the midline and located 2 cm in front of the coronal suture. Cranial CT revealed a bone defect of 0.5 cm in the area 2 cm in front of the coronal suture on the midline, tetraventricular and extensive subarachnoid hemorrhage and parenchymal hematoma in the frontal area. It was initially thought to be a gunshot injury; however, on cranial CT, no bullet fragments or bullet exit hole was observed. A cervicothoracal direct graph was obtained and an image that might have been compatible with a bullet core was detected at Th 2-3 vertebra level. Although gunshot injuries are generally well- known, this may not be a very familiar topic for neurosurgeons. The primary aim of this report is to emphasize that a bullet round randomly fired into the air ascends in reverse direction to gravity and after reaching a zero point, it returns to the ground at a high velocity that facilitates its penetration into the skull according to a principal physics law.

  15. Youth, Guns, and the Juvenile Justice System. Research Report.

    ERIC Educational Resources Information Center

    Butts, Jeffrey; Coggeshall, Mark; Gouvis, Caterina; Mears, Daniel; Travis, Jeremy; Waul, Michelle; White, Ruth

    This report documents trends in youth gun violence and the response within the justice system, noting the growing variety of data resources available to investigate the effect of new gun laws on youth, communities, and public safety. The first section reviews recent trends, examining the major wave of gun violence in the United States during the…

  16. Recoil Experiments Using a Compressed Air Cannon

    ERIC Educational Resources Information Center

    Taylor, Brett

    2006-01-01

    Ping-Pong vacuum cannons, potato guns, and compressed air cannons are popular and dramatic demonstrations for lecture and lab. Students enjoy them for the spectacle, but they can also be used effectively to teach physics. Recently we have used a student-built compressed air cannon as a laboratory activity to investigate impulse, conservation of…

  17. Water guns affect abundance and behavior of bigheaded carp and native fish differently

    USGS Publications Warehouse

    Rivera, Jose; Glover, David C.; Kocovsky, Patrick; Garvey, James E.; Gaikowski, Mark; Jensen, Nathan R.; Adams, Ryan F.

    2018-01-01

    Water guns have shown the potential to repel nuisance aquatic organisms. This study examines the effects of exposure to a 1966.4 cm3 seismic water gun array (two guns) on the abundance and behavior of Bighead Carp Hypophthalmichthys nobilis, Silver Carp H. molitrix (collectively referred to as bigheaded carp) and native fishes (e.g., Smallmouth Buffalo Ictiobus bubalus). Water guns were deployed in a channel that connects the Illinois River to backwater quarry pits that contained a large transient population of bigheaded carp. To evaluate the effect of water guns, mobile side-looking split-beam hydroacoustic surveys were conducted before, during and between replicated water gun firing periods. Water guns did not affect abundance of bigheaded carp, but abundance of native fish detected during the firing treatment was 43 and 34% lower than the control and water guns off treatments, respectively. The proximity of bigheaded carp to the water gun array was similar between the water guns on and water guns off treatments. In contrast, the closest detected native fish were detected farther from the water guns during the water guns on treatment (mean ± SE, 32.38 ± 3.32 m) than during the water guns off treatment (15.04 ± 1.59 m). The water gun array had a greater impact on native fish species than on bigheaded carp. Caution should be taken to the extrapolation of these results to other fish species and to fish exposed to water guns in different environments (e.g., reduced shoreline interaction) or exposure to a larger array of water guns, or for use of water guns for purposes other than a barrier.

  18. 46th Annual Gun and Missile Systems Conference and Exhibition

    DTIC Science & Technology

    2011-09-01

    Grade Sensors Through Use of Accelerated Aging Principles Mr. Scott Gift 11657 Modeling of the Autofrettage Processes of a Gun Barrel Mr. Sudhir...Emissions Measured on the Outer Portion of a Composite Barrel Ms. Rushie Ghimire GUN & MISSILE SYSTEMS ADDITIONAL AUTHORS GUN & MISSILE SYSTEMS...X 3BCT 2BCT X 1BCT TACP COLT • BLUFOR scout squad engaged by enemy infantry and are overwhelmed by heavy machine gun fire 100m to their northwest

  19. VIEW OF SOUTH GUN EMPLACEMENT. NOTE THE EXCAVATED EDGE OF ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    VIEW OF SOUTH GUN EMPLACEMENT. NOTE THE EXCAVATED EDGE OF THE GUN BLOCK IN THE FOREGROUND. VIEW FACING NORTH - U.S. Naval Base, Pearl Harbor, Ford Island 5-Inch Antiaircraft Battery, South Gun Emplacement, Ford Island, Pearl City, Honolulu County, HI

  20. The electric rail gun for space propulsion

    NASA Technical Reports Server (NTRS)

    Bauer, D. P.; Barber, J. P.; Vahlberg, C. J.

    1981-01-01

    An analytic feasibility investigation of an electric propulsion concept for space application is described. In this concept, quasistatic thrust due to inertial reaction to repetitively accelerated pellets by an electric rail gun is used to propel a spacecraft. The study encompasses the major subsystems required in an electric rail gun propulsion system. The mass, performance, and configuration of each subsystem are described. Based on an analytic model of the system mass and performance, the electric rail gun mission performance as a reusable orbital transfer vehicle (OTV) is analyzed and compared to a 30 cm ion thruster system (BIMOD) and a chemical propulsion system (IUS) for payloads with masses of 1150 kg and 2300 kg. For system power levels in the range from 25 kW(e) to 100 kW(e) an electric rail gun OTV is more attractive than a BIMOD system for low Earth orbit to geosynchronous orbit transfer durations in the range from 20 to 120 days.

  1. Direct launch using the electric rail gun

    NASA Technical Reports Server (NTRS)

    Barber, J. P.

    1983-01-01

    The concept explored involves using a large single stage electric rail gun to achieve orbital velocities. Exit aerodynamics, launch package design and size, interior ballistics, system and component sizing and design concepts are treated. Technology development status and development requirements are identified and described. The expense of placing payloads in Earth orbit using conventional chemical rockets is considerable. Chemical rockets are very inefficient in converting chemical energy into payload kinetic energy. A rocket motor is relatively expensive and is usually expended on each launch. In addition specialized and expensive forms of fuel are required. Gun launching payloads directly to orbit from the Earth's surface is a possible alternative. Guns are much more energy efficient than rockets. The high capital cost of the gun installation can be recovered by reusing it over and over again. Finally, relatively inexpensive fuel and large quantities of energy are readily available to a fixed installation on the Earth's surface.

  2. Impact of Firearm Availability and Gun Regulation on State Suicide Rates.

    PubMed

    Kposowa, Augustine; Hamilton, David; Wang, Katy

    2016-12-01

    Past studies on suicide have investigated the association of firearm ownership and suicide risk in the United States. The aim of the present study was to build on previous work by examining the impact of firearm storage practices and the strictness of firearm regulation on suicide rates at the state level. Data were compiled from primarily three sources. Suicide and firearm ownership information was obtained from the Centers for Disease Control and Prevention. Strictness of handgun regulation was derived from figures available at the Law Center to Prevent Violence, and controls were taken from the US Bureau of the Census. Mixed models were fitted to the data. Household firearm ownership was strongly associated with both suicide by all mechanisms, and firearm suicide. Storage practices had especially elevated consequences on suicide rates. Percent with loaded guns and gun readiness increased suicide rates, and strictness of gun regulation reduced suicide rates. Ready access to firearms can make a difference between life and death. Loaded and unlocked firearms within reach become risk factors for fatal outcomes from suicidal behavior. Future research might want to examine ways of obtaining more recent data on individual firearm ownership. This study proposes several policy recommendations for suicide prevention. © 2016 The American Association of Suicidology.

  3. Pediatricians' involvement in gun injury prevention.

    PubMed

    Olson, L M; Christoffel, K K; O'Connor, K G

    2007-04-01

    Injuries from small arms are of concern internationally. The health perspective is an emerging aspect of international work to reduce these injuries. This aspect has been evident in US firearm injury prevention work for over a decade, exhibited by strong statements from the American Academy of Pediatrics (AAP) to remove firearms from children's environments. To assess trends among US pediatricians related to firearm injury prevention counseling practices and attitudes toward gun legislation. National random sample, mailed surveys of AAP members: (1) 1994 (response rate = 68.9%, n = 982); (2) 2000 (response rate = 62.4%, n = 922). chi(2) Tests were used to assess bivariate relationships and logistic regression to assess multivariate relationships regarding counseling practices. Respondents in both years believed that violence prevention should be a priority for pediatricians (91.4% and 92.0%) and reported always or sometimes recommending handgun removal from the home (46.2% and 55.9%, respectively). In 2000, 74% of the respondents were comfortable discussing firearm safety; fewer thought they had sufficient training (32.7%) or time (27.5%) to discuss firearms. In 1994 and 2000, the likelihood of counseling on handgun removal was positively related to recent experience treating a gun injury, female sex and not owning a gun. In both years, >80% of pediatricians thought that gun control legislation or regulations would reduce injury and death. US pediatricians continue to adopt policies promoting gun injury prevention. The practices and attitudes of pediatricians may be important for public education strategies regarding firearm injury prevention in the US and internationally.

  4. ION GUN

    DOEpatents

    Dandl, R.A.

    1961-10-24

    An ion gun is described for the production of an electrically neutral ionized plasma. The ion gun comprises an anode and a cathode mounted in concentric relationship with a narrow annulus between. The facing surfaces of the rear portions of the anode and cathode are recessed to form an annular manifold. Positioned within this manifold is an annular intermediate electrode aligned with the an nulus between the anode and cathode. Gas is fed to the manifold and an arc discharge is established between the anode and cathode. The gas is then withdrawn from the manifold through the annulus between the anode and cathode by a pressure differential. The gas is then ionized by the arc discharge across the annulus. The ionized gas is withdrawn from the annulus by the combined effects of the pressure differential and a collimating magnetic field. In a 3000 gauss magnetic field, an arc voltage of 1800 volts, and an arc current of 0.2 amp, a plasma of about 3 x 10/sup 11/ particles/cc is obtained. (AEC)

  5. Planning Support for Maintenance and Overhaul of Gun Weapon Systems

    DTIC Science & Technology

    1981-05-01

    13 (shielded twin) gun mounts are targeted to receive ORDALTs 9335 and 9409. Sixty-seven ship hulls are involved in the program, for a total of 147...gun mounts (excluding four training mounts ). Seventy-three Mod 0 and seventy-four Mod 13 gun mounts are included in the program, for an estimated total ...of gun mounts included in the GWSIP. Each mount will receive one amplifier ORDALT, for a. a total of 147, and two upgraded oscillating assemblies

  6. Light gas gun with reduced timing jitter

    DOEpatents

    Laabs, Gary W.; Funk, David J.; Asay, Blaine W.

    1998-01-01

    Gas gun with reduced timing jitter. A gas gun having a prepressurized projectile held in place with a glass rod in compression is described. The glass rod is destroyed with an explosive at a precise time which allows a restraining pin to be moved and free the projectile.

  7. Gun Control: The Debate and Public Policy.

    ERIC Educational Resources Information Center

    Watkins, Christine

    1997-01-01

    Provides an overview and background information on the debate over gun control, as well as several teaching ideas. Handouts include a list of related topics drawn from various disciplines (economics, U.S. history), seven arguments for and against gun control, and a set of policy evaluation guidelines. (MJP)

  8. Does gun accessibility lead to violence-related injury?

    PubMed

    Downey, La Vonne A; Zun, Leslie S; Burke, Trena; Jefferson, Tangula

    2013-02-01

    Because of high rates of violent gun-related injuries seen in emergency department (EDs), the ED has become involved in prevention violence intervention. The purpose of the study was to determine the relation between access to guns and the risk of violence-related injuries in youth and young adults. This study was a convenience sample in an inner-city level I trauma center. A 28-item validated questionnaire consisting of a short questionnaire about guns, the New York City Youth Violence Survey, and the SAGE Baseline Survey was given to 201 subjects. Half of the subjects were victims of violence and half were seen for nonviolence-related problems. Subjects with violence-related injuries did not have a higher rate of accessibility to guns. They did, however, show a difference in their attitudes toward guns. The subjects who came into the ED with violence-related injuries believed that having a weapon was a way to avoid a fight (F = 4.68, P = 0.032). They were more likely to have grabbed or shoved someone in the last 6 months (F = 5.18, P = 0.025), punched someone in the last 6 months (F = 11.9, P = 0.011), and have been seen in the ED within the last 6 months for a injury related to being punched, attacked, or shot (F = 117, P = 0.00), as compared to those with nonviolence-related injuries. There was no difference between the two subject groups in terms of their being victims of violence and the rate of gun accessibility. There was, however, a difference in their attitudes toward guns.

  9. Analysis of air quality management with emphasis on transportation sources

    NASA Technical Reports Server (NTRS)

    English, T. D.; Divita, E.; Lees, L.

    1980-01-01

    The current environment and practices of air quality management were examined for three regions: Denver, Phoenix, and the South Coast Air Basin of California. These regions were chosen because the majority of their air pollution emissions are related to mobile sources. The impact of auto exhaust on the air quality management process is characterized and assessed. An examination of the uncertainties in air pollutant measurements, emission inventories, meteorological parameters, atmospheric chemistry, and air quality simulation models is performed. The implications of these uncertainties to current air quality management practices is discussed. A set of corrective actions are recommended to reduce these uncertainties.

  10. Cure violence: a public health model to reduce gun violence.

    PubMed

    Butts, Jeffrey A; Roman, Caterina Gouvis; Bostwick, Lindsay; Porter, Jeremy R

    2015-03-18

    Scholars and practitioners alike in recent years have suggested that real and lasting progress in the fight against gun violence requires changing the social norms and attitudes that perpetuate violence and the use of guns. The Cure Violence model is a public health approach to gun violence reduction that seeks to change individual and community attitudes and norms about gun violence. It considers gun violence to be analogous to a communicable disease that passes from person to person when left untreated. Cure Violence operates independently of, while hopefully not undermining, law enforcement. In this article, we describe the theoretical basis for the program, review existing program evaluations, identify several challenges facing evaluators, and offer directions for future research.

  11. 27 CFR 479.105 - Transfer and possession of machine guns.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... machine guns. 479.105 Section 479.105 Alcohol, Tobacco Products, and Firearms BUREAU OF ALCOHOL, TOBACCO, FIREARMS, AND EXPLOSIVES, DEPARTMENT OF JUSTICE FIREARMS AND AMMUNITION MACHINE GUNS, DESTRUCTIVE DEVICES, AND CERTAIN OTHER FIREARMS Registration and Identification of Firearms Machine Guns § 479.105 Transfer...

  12. 27 CFR 479.105 - Transfer and possession of machine guns.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... machine guns. 479.105 Section 479.105 Alcohol, Tobacco Products, and Firearms BUREAU OF ALCOHOL, TOBACCO, FIREARMS, AND EXPLOSIVES, DEPARTMENT OF JUSTICE FIREARMS AND AMMUNITION MACHINE GUNS, DESTRUCTIVE DEVICES, AND CERTAIN OTHER FIREARMS Registration and Identification of Firearms Machine Guns § 479.105 Transfer...

  13. 27 CFR 479.105 - Transfer and possession of machine guns.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... machine guns. 479.105 Section 479.105 Alcohol, Tobacco Products, and Firearms BUREAU OF ALCOHOL, TOBACCO, FIREARMS, AND EXPLOSIVES, DEPARTMENT OF JUSTICE FIREARMS AND AMMUNITION MACHINE GUNS, DESTRUCTIVE DEVICES, AND CERTAIN OTHER FIREARMS Registration and Identification of Firearms Machine Guns § 479.105 Transfer...

  14. 27 CFR 479.105 - Transfer and possession of machine guns.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... machine guns. 479.105 Section 479.105 Alcohol, Tobacco Products, and Firearms BUREAU OF ALCOHOL, TOBACCO, FIREARMS, AND EXPLOSIVES, DEPARTMENT OF JUSTICE FIREARMS AND AMMUNITION MACHINE GUNS, DESTRUCTIVE DEVICES, AND CERTAIN OTHER FIREARMS Registration and Identification of Firearms Machine Guns § 479.105 Transfer...

  15. 27 CFR 479.105 - Transfer and possession of machine guns.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... machine guns. 479.105 Section 479.105 Alcohol, Tobacco Products, and Firearms BUREAU OF ALCOHOL, TOBACCO, FIREARMS, AND EXPLOSIVES, DEPARTMENT OF JUSTICE FIREARMS AND AMMUNITION MACHINE GUNS, DESTRUCTIVE DEVICES, AND CERTAIN OTHER FIREARMS Registration and Identification of Firearms Machine Guns § 479.105 Transfer...

  16. Comparison of air-kerma strength determinations for HDR (192)Ir sources.

    PubMed

    Rasmussen, Brian E; Davis, Stephen D; Schmidt, Cal R; Micka, John A; Dewerd, Larry A

    2011-12-01

    To perform a comparison of the interim air-kerma strength standard for high dose rate (HDR) (192)Ir brachytherapy sources maintained by the University of Wisconsin Accredited Dosimetry Calibration Laboratory (UWADCL) with measurements of the various source models using modified techniques from the literature. The current interim standard was established by Goetsch et al. in 1991 and has remained unchanged to date. The improved, laser-aligned seven-distance apparatus of the University of Wisconsin Medical Radiation Research Center (UWMRRC) was used to perform air-kerma strength measurements of five different HDR (192)Ir source models. The results of these measurements were compared with those from well chambers traceable to the original standard. Alternative methodologies for interpolating the (192)Ir air-kerma calibration coefficient from the NIST air-kerma standards at (137)Cs and 250 kVp x rays (M250) were investigated and intercompared. As part of the interpolation method comparison, the Monte Carlo code EGSnrc was used to calculate updated values of A(wall) for the Exradin A3 chamber used for air-kerma strength measurements. The effects of air attenuation and scatter, room scatter, as well as the solution method were investigated in detail. The average measurements when using the inverse N(K) interpolation method for the Classic Nucletron, Nucletron microSelectron, VariSource VS2000, GammaMed Plus, and Flexisource were found to be 0.47%, -0.10%, -1.13%, -0.20%, and 0.89% different than the existing standard, respectively. A further investigation of the differences observed between the sources was performed using MCNP5 Monte Carlo simulations of each source model inside a full model of an HDR 1000 Plus well chamber. Although the differences between the source models were found to be statistically significant, the equally weighted average difference between the seven-distance measurements and the well chambers was 0.01%, confirming that it is not necessary to

  17. The Need for a Permanent Gun System On the F-35 Joint Strike Fighter

    DTIC Science & Technology

    2007-04-01

    subject material . Finally, I would like to thank my wife, Niki, for her love, support and understanding. iv Abstract Historically, the United...concept that showed the most promise involved building upon the Gatlin gun technology of the nineteenth century.20 By using a multiple barrel design...one form or another, has been present since military pilots first took to the air. From simply using their own handguns to shoot at enemy aircraft

  18. Individual-level risk factors for gun victimization in a sample of probationers.

    PubMed

    Wells, William; Chermak, Steven

    2011-07-01

    Interventions aimed at preventing the important problem of gun injuries could be improved with an understanding of whether there are unique factors that place individuals at an increased risk of gun victimization. Much remains to be known about the victims of gun violence. The purpose of this article is to assess whether there are individual-level variables uniquely related to the likelihood of experiencing a gun victimization in a sample of probationers, individuals already at a heightened risk for criminal victimization. Self-report data were collected from 235 felony probationers about, for instance, gun and nongun victimization, gang involvement, and drug sales. Results show different variables are related to nongun victimization and gun victimization. In the current sample, involvement in gun crimes are linked to an increased risk of gun victimization. Violent offending and residential stability are associated with an increased chance of crime victimization.

  19. 76 FR 13514 - National Emission Standards for Hazardous Air Pollutants for Chemical Manufacturing Area Sources

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-03-14

    ... National Emission Standards for Hazardous Air Pollutants for Chemical Manufacturing Area Sources AGENCY... Emission Standards for Hazardous Air Pollutants for Chemical Manufacturing Area Sources. Among the... Emission Standards for Hazardous Air Pollutants for Chemical Manufacturing Area Sources (CMAS) on October...

  20. Research on Near Roadway and Other Near Source Air Pollution

    EPA Pesticide Factsheets

    Research has shown that living and working near sources of air pollution can lead to higher exposures to air contaminants many of which contribute to adverse health effects including reduced lung function, asthma, cardiovascular disease and premature death

  1. Differences Between New and Long-Standing US Gun Owners: Results From a National Survey.

    PubMed

    Wertz, Joseph; Azrael, Deborah; Hemenway, David; Sorenson, Susan; Miller, Matthew

    2018-07-01

    To quantify the proportion of current US gun owners who are new to owning firearms and compare new versus long-standing gun owners with respect to their firearms and firearm-related behaviors. We performed a cross-sectional analysis of a nationally representative probability-based online survey conducted in 2015 in the United States. We defined new gun owners as current firearm owners who acquired all of their firearms within the past 5 years, but who lived in a home without a gun at some time over the past 5 years. We defined long-standing firearm owners as all other current gun owners. New gun owners represented 10% of all current US adult gun owners. In addition to being younger than long-standing gun owners, new gun owners were more likely to be liberal, own fewer guns, own handguns, own guns only for protection, and store guns in a safe manner. Gun ownership is dynamic, with approximately 1 million Americans becoming new gun owners each year. Public Health Implications. Clinical guidelines should be updated to explicitly endorse re-evaluating household firearm status at regular intervals.

  2. Light gas gun with reduced timing jitter

    DOEpatents

    Laabs, G.W.; Funk, D.J.; Asay, B.W.

    1998-06-09

    Gas gun with reduced timing jitter is disclosed. A gas gun having a prepressurized projectile held in place with a glass rod in compression is described. The glass rod is destroyed with an explosive at a precise time which allows a restraining pin to be moved and free the projectile. 4 figs.

  3. Gun policy and serious mental illness: priorities for future research and policy.

    PubMed

    McGinty, Emma Elizabeth; Webster, Daniel W; Barry, Colleen L

    2014-01-01

    In response to recent mass shootings, policy makers have proposed multiple policies to prevent persons with serious mental illness from having guns. The political debate about these proposals is often uninformed by research. To address this gap, this review article summarizes the research related to gun restriction policies that focus on serious mental illness. Gun restriction policies were identified by researching the THOMAS legislative database, state legislative databases, prior review articles, and the news media. PubMed, PsycINFO, and Web of Science databases were searched for publications between 1970 and 2013 that addressed the relationship between serious mental illness and violence, the effectiveness of gun policies focused on serious mental illness, the potential for such policies to exacerbate negative public attitudes, and the potential for gun restriction policies to deter mental health treatment seeking. Limited research suggests that federal law restricting gun possession by persons with serious mental illness may prevent gun violence from this population. Promotion of policies to prevent persons with serious mental illness from having guns does not seem to exacerbate negative public attitudes toward this group. Little is known about how restricting gun possession among persons with serious mental illness affects suicide risk or mental health treatment seeking. Future studies should examine how gun restriction policies for serious mental illness affect suicide, how such policies are implemented by states, how persons with serious mental illness perceive policies that restrict their possession of guns, and how gun restriction policies influence mental health treatment seeking among persons with serious mental illness.

  4. Dynamic Radioactive Source for Evaluating and Demonstrating Time-dependent Performance of Continuous Air Monitors.

    PubMed

    McLean, Thomas D; Moore, Murray E; Justus, Alan L; Hudston, Jonathan A; Barbé, Benoît

    2016-11-01

    Evaluation of continuous air monitors in the presence of a plutonium aerosol is time intensive, expensive, and requires a specialized facility. The Radiation Protection Services Group at Los Alamos National Laboratory has designed a Dynamic Radioactive Source, intended to replace plutonium aerosol challenge testing. The Dynamic Radioactive Source is small enough to be inserted into the sampler filter chamber of a typical continuous air monitor. Time-dependent radioactivity is introduced from electroplated sources for real-time testing of a continuous air monitor where a mechanical wristwatch motor rotates a mask above an alpha-emitting electroplated disk source. The mask is attached to the watch's minute hand, and as it rotates, more of the underlying source is revealed. The measured alpha activity increases with time, simulating the arrival of airborne radioactive particulates at the air sampler inlet. The Dynamic Radioactive Source allows the temporal behavior of puff and chronic release conditions to be mimicked without the need for radioactive aerosols. The new system is configurable to different continuous air monitor designs and provides an in-house testing capability (benchtop compatible). It is a repeatable and reusable system and does not contaminate the tested air monitor. Test benefits include direct user control, realistic (plutonium) aerosol spectra, and iterative development of continuous air monitor alarm algorithms. Data obtained using the Dynamic Radioactive Source has been used to elucidate alarm algorithms and to compare the response time of two commercial continuous air monitors.

  5. Dynamic Radioactive Source for Evaluating and Demonstrating Time-dependent Performance of Continuous Air Monitors

    DOE PAGES

    McLean, Thomas D.; Moore, Murray E.; Justus, Alan L.; ...

    2016-01-01

    Evaluation of continuous air monitors in the presence of a plutonium aerosol is time intensive, expensive, and requires a specialized facility. The Radiation Protection Services Group at Los Alamos National Laboratory has designed a Dynamic Radioactive Source, intended to replace plutonium aerosol challenge testing. Furthermore, the Dynamic Radioactive Source is small enough to be inserted into the sampler filter chamber of a typical continuous air monitor. Time-dependent radioactivity is introduced from electroplated sources for real-time testing of a continuous air monitor where a mechanical wristwatch motor rotates a mask above an alpha-emitting electroplated disk source. The mask is attached tomore » the watch’s minute hand, and as it rotates, more of the underlying source is revealed. The alpha activity we measured increases with time, simulating the arrival of airborne radioactive particulates at the air sampler inlet. The Dynamic Radioactive Source allows the temporal behavior of puff and chronic release conditions to be mimicked without the need for radioactive aerosols. The new system is configurable to different continuous air monitor designs and provides an in-house testing capability (benchtop compatible). It is a repeatable and reusable system and does not contaminate the tested air monitor. Test benefits include direct user control, realistic (plutonium) aerosol spectra, and iterative development of continuous air monitor alarm algorithms. We also used data obtained using the Dynamic Radioactive Source to elucidate alarm algorithms and to compare the response time of two commercial continuous air monitors.« less

  6. Panama Canal Expansion Illustrates Need for Multimodal Near-Source Air Quality Assessment

    EPA Science Inventory

    The compelling issue raised is potential major changes in goods movement due to the Panama Canal expansion and considerations for near-source air quality. Near-source air quality may be affected both at near-port areas as well as along the freight transportation corridor.

  7. The US gun stock: results from the 2004 national firearms survey.

    PubMed

    Hepburn, L; Miller, M; Azrael, D; Hemenway, D

    2007-02-01

    To examine the size and composition of the privately held firearm stock in the US; and to describe demographic patterns of firearm ownership and motivations for ownership. A nationally representative household telephone survey of 2770 adults aged>or=18 years living in the US, conducted in the spring of 2004. Responses to questions regarding firearm ownership, the number and types of guns owned, and motivations for ownership. 38% of households and 26% of individuals reported owning at least one firearm. This corresponds to 42 million US households with firearms, and 57 million adult gun owners. 64% of gun owners or 16% of American adults reported owning at least one handgun. Long guns represent 60% of the privately held gun stock. Almost half (48%) of all individual gun owners reported owning>or=4 firearms. Men more often reported firearm ownership, with 45% stating that they personally owned at least one firearm, compared with 11% for women. The US population continues to contain at least one firearm for every adult, and ownership is becoming increasingly concentrated. Long guns are the most prevalent type of gun in the US but handgun ownership is widespread. Ownership demographic patterns support findings of previous studies.

  8. International correlations between gun ownership and rates of homicide and suicide.

    PubMed Central

    Killias, M

    1993-01-01

    OBJECTIVE: To examine international correlations between reported rates of household gun ownership and rates of homicide and suicide with a gun. DESIGN: Survey. POPULATION: People who responded to a telephone survey conducted by the 1989 International Crime Survey in 11 European countries, Australia, Canada and the United States. RESULTS: Positive correlations were obtained between the rates of household gun ownership and the national rates of homicide and suicide as well as the proportions of homicides and suicides committed with a gun. There was no negative correlation between the rates of ownership and the rates of homicide and suicide committed by other means; this indicated that the other means were not used to "compensate" for the absence of guns in countries with a lower rate of gun ownership. CONCLUSION: Larger studies are needed to examine more closely possible confounding factors such as the national tendency toward violent solutions, and more information on the type and availability of guns will be helpful in future studies. Nevertheless, the correlations detected in this study suggest that the presence of a gun in the home increases the likelihood of homicide or suicide. PMID:8485675

  9. Performance of a clinical gridded electron gun in magnetic fields: Implications for MRI-linac therapy.

    PubMed

    Whelan, Brendan; Holloway, Lois; Constantin, Dragos; Oborn, Brad; Bazalova-Carter, Magdalena; Fahrig, Rebecca; Keall, Paul

    2016-11-01

    MRI-linac therapy is a rapidly growing field, and requires that conventional linear accelerators are operated with the fringe field of MRI magnets. One of the most sensitive accelerator components is the electron gun, which serves as the source of the beam. The purpose of this work was to develop a validated finite element model (FEM) model of a clinical triode (or gridded) electron gun, based on accurate geometric and electrical measurements, and to characterize the performance of this gun in magnetic fields. The geometry of a Varian electron gun was measured using 3D laser scanning and digital calipers. The electric potentials and emission current of these guns were measured directly from six dose matched true beam linacs for the 6X, 10X, and 15X modes of operation. Based on these measurements, a finite element model (FEM) of the gun was developed using the commercial software opera/scala. The performance of the FEM model in magnetic fields was characterized using parallel fields ranging from 0 to 200 G in the in-line direction, and 0-35 G in the perpendicular direction. The FEM model matched the average measured emission current to within 5% across all three modes of operation. Different high voltage settings are used for the different modes; the 6X, 10X, and 15X modes have an average high voltage setting of 15, 10, and 11 kV. Due to these differences, different operating modes show different sensitivities in magnetic fields. For in line fields, the first current loss occurs at 40, 20, and 30 G for each mode. This is a much greater sensitivity than has previously been observed. For perpendicular fields, first beam loss occurred at 8, 5, and 5 G and total beam loss at 27, 22, and 20 G. A validated FEM model of a clinical triode electron gun has been developed based on accurate geometric and electrical measurements. Three different operating modes were simulated, with a maximum mean error of 5%. This gun shows greater sensitivity to in-line magnetic fields than

  10. Performance of a clinical gridded electron gun in magnetic fields: Implications for MRI-linac therapy

    PubMed Central

    Whelan, Brendan; Holloway, Lois; Constantin, Dragos; Oborn, Brad; Bazalova-Carter, Magdalena; Fahrig, Rebecca; Keall, Paul

    2016-01-01

    Purpose: MRI-linac therapy is a rapidly growing field, and requires that conventional linear accelerators are operated with the fringe field of MRI magnets. One of the most sensitive accelerator components is the electron gun, which serves as the source of the beam. The purpose of this work was to develop a validated finite element model (FEM) model of a clinical triode (or gridded) electron gun, based on accurate geometric and electrical measurements, and to characterize the performance of this gun in magnetic fields. Methods: The geometry of a Varian electron gun was measured using 3D laser scanning and digital calipers. The electric potentials and emission current of these guns were measured directly from six dose matched true beam linacs for the 6X, 10X, and 15X modes of operation. Based on these measurements, a finite element model (FEM) of the gun was developed using the commercial software opera/scala. The performance of the FEM model in magnetic fields was characterized using parallel fields ranging from 0 to 200 G in the in-line direction, and 0–35 G in the perpendicular direction. Results: The FEM model matched the average measured emission current to within 5% across all three modes of operation. Different high voltage settings are used for the different modes; the 6X, 10X, and 15X modes have an average high voltage setting of 15, 10, and 11 kV. Due to these differences, different operating modes show different sensitivities in magnetic fields. For in line fields, the first current loss occurs at 40, 20, and 30 G for each mode. This is a much greater sensitivity than has previously been observed. For perpendicular fields, first beam loss occurred at 8, 5, and 5 G and total beam loss at 27, 22, and 20 G. Conclusions: A validated FEM model of a clinical triode electron gun has been developed based on accurate geometric and electrical measurements. Three different operating modes were simulated, with a maximum mean error of 5%. This gun shows greater

  11. The Baltimore Youth Ammunition Initiative: a model application of local public health authority in preventing gun violence.

    PubMed

    Lewin, Nancy L; Vernick, Jon S; Beilenson, Peter L; Mair, Julie S; Lindamood, Melisa M; Teret, Stephen P; Webster, Daniel W

    2005-05-01

    In 2002, the Baltimore City Health Department, in collaboration with the Baltimore Police Department and the Johns Hopkins Center for Gun Policy and Research, launched the Youth Ammunition Initiative. The initiative addressed Baltimore's problem of youth gun violence by targeting illegal firearm ammunition sales to the city's young people. The initiative included undercover "sting" investigations of local businesses and issuance of health department violation and abatement notices. Intermediate results included the passage of 2 Baltimore city council ordinances regulating ammunition sales and reducing the number of outlets eligible to sell ammunition. Although it is too early to assess effects on violent crime, the intervention could theoretically reduce youth violence by interrupting one source of ammunition to youths. More important, the initiative can serve as a policy model for health commissioners seeking to become more active in gun violence prevention efforts.

  12. Pediatricians’ involvement in gun injury prevention

    PubMed Central

    Olson, L M; Christoffel, K K; O’Connor, K G

    2007-01-01

    Background: Injuries from small arms are of concern internationally. The health perspective is an emerging aspect of international work to reduce these injuries. This aspect has been evident in US firearm injury prevention work for over a decade, exhibited by strong statements from the American Academy of Pediatrics (AAP) to remove firearms from children’s environments. Objectives: To assess trends among US pediatricians related to firearm injury prevention counseling practices and attitudes toward gun legislation. Design: National random sample, mailed surveys of AAP members: (1) 1994 (response rate  = 68.9%, n = 982); (2) 2000 (response rate  = 62.4%, n = 922). χ2 Tests were used to assess bivariate relationships and logistic regression to assess multivariate relationships regarding counseling practices. Results: Respondents in both years believed that violence prevention should be a priority for pediatricians (91.4% and 92.0%) and reported always or sometimes recommending handgun removal from the home (46.2% and 55.9%, respectively). In 2000, 74% of the respondents were comfortable discussing firearm safety; fewer thought they had sufficient training (32.7%) or time (27.5%) to discuss firearms. In 1994 and 2000, the likelihood of counseling on handgun removal was positively related to recent experience treating a gun injury, female sex and not owning a gun. In both years, >80% of pediatricians thought that gun control legislation or regulations would reduce injury and death. Conclusions: US pediatricians continue to adopt policies promoting gun injury prevention. The practices and attitudes of pediatricians may be important for public education strategies regarding firearm injury prevention in the US and internationally. PMID:17446249

  13. Guns, Mental Illness, and the Law: Introduction to This Issue.

    PubMed

    Swanson, Jeffrey W; Felthous, Alan R

    2015-06-01

    Firearm violence is a top-tier public health problem in the U.S., killing 33,563 and injuring an additional 81,396 people in 2012 (Centers for Disease Control and Prevention, CDC, ). Given constitutional protection and the cultural entrenchment of private gun ownership in the U.S., it is likely that guns will remain widely accessible--and largely unrestricted--for the foreseeable future. Therefore, most policies and laws intended to reduce firearm violence focus selectively on preventing "dangerous people" from having access to guns. That is a formidable challenge. How do we think productively about guns and mental illness in this context, and about the role of law in lessening the toll of gun violence? Copyright © 2015 John Wiley & Sons, Ltd.

  14. Multipacting simulation and test results of BNL 704 MHz SRF gun

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Xu W.; Belomestnykh, S.; Ben-Zvi, I.

    The BNL 704MHz SRF gun has a grooved choke joint to support the photo-cathode. Due to the distortion of grooves at the choke joint during the BCP for the choke joint, several multipacting barriers showed up when it was tested with Nb cathode stalk at JLab. We built a setup to use the spare large grain SRF cavity to test and condition the multipacting at BNL with various power sources up to 50kW. The test is carried out in three stages: testing the cavity performance without cathode, testing the cavity with the Nb cathode stalk that was used at Jlab,more » and testing the cavity with a copper cathode stalk that is based on the design for the SRF gun. This paper summarizes the results of multipacting simulation, and presents the large grain cavity test setup and the test results.« less

  15. Diagnostic Air Quality Model Evaluation of Source-Specific ...

    EPA Pesticide Factsheets

    Ambient measurements of 78 source-specific tracers of primary and secondary carbonaceous fine particulate matter collected at four midwestern United States locations over a full year (March 2004–February 2005) provided an unprecedented opportunity to diagnostically evaluate the results of a numerical air quality model. Previous analyses of these measurements demonstrated excellent mass closure for the variety of contributing sources. In this study, a carbon-apportionment version of the Community Multiscale Air Quality (CMAQ) model was used to track primary organic and elemental carbon emissions from 15 independent sources such as mobile sources and biomass burning in addition to four precursor-specific classes of secondary organic aerosol (SOA) originating from isoprene, terpenes, aromatics, and sesquiterpenes. Conversion of the source-resolved model output into organic tracer concentrations yielded a total of 2416 data pairs for comparison with observations. While emission source contributions to the total model bias varied by season and measurement location, the largest absolute bias of −0.55 μgC/m3 was attributed to insufficient isoprene SOA in the summertime CMAQ simulation. Biomass combustion was responsible for the second largest summertime model bias (−0.46 μgC/m3 on average). Several instances of compensating errors were also evident; model underpredictions in some sectors were masked by overpredictions in others. The National Exposure Research L

  16. [Contextual study of Airsoft gun related ocular injuries].

    PubMed

    Rambaud, C; Tabary, A; Contraires, G; El Hassan, F; Labalette, P

    2013-03-01

    Airsoft guns have become more common in France since the Decree of March 24, 1999, allowing people over 18 years of age to use weapons with an energy level below 2J. The present study aimed to assess the relationship between the context of Airsoft gun pellet related ocular injuries and their clinical consequences, in order to determine an effective prevention strategy. A retrospective analysis of ocular injuries due to Airsoft gun pellets was conducted in two hospitals in northern France between September 2009 and August 2010. Six patients with a mean age of 12.6 ± 3.2 years were included. The most frequent injuries were corneal abrasion, hyphema and iris trauma. Functional sequelae were observed in 50% of cases and surgical intervention was necessary in one third of cases. A direct shot had occurred in all cases. In 83% of cases, the accident took place while playing in or around the house. In one out of every two cases, the gun had been won at a booth in a fair or had been purchased in a big-box store and in no cases did the patients own safety glasses. The strong appeal of Airsoft guns to minors leads us to propose several practical measures to help protect them, with the main one being to forbid selling these guns outside of specialized stores. Copyright © 2012 Elsevier Masson SAS. All rights reserved.

  17. Characterization of the C-2W Plasma Guns

    NASA Astrophysics Data System (ADS)

    Dubois, Ami; Sokolov, Vladimir; Korepanov, Sergey; Osin, Dima; Player, Gabriel; TAE Team

    2017-10-01

    Previous use of coaxial arc discharge plasma guns on the C-2U device exhibited great success in plasma stabilization and improved confinement. On the C-2W experiment, arc discharge plasma guns will again be used to facilitate the electrical connection between the plasma core and the divertor electrodes in order to maintain the electrode edge biasing and induce E x B shear to control plasma rotation. Each plasma gun contains an internal solenoid used to shape the plasma stream. Characterization of electron density (ne) , electron temperature (Te) , floating potential (Vf) , and total plasma flux in an arc discharge lasting 6 ms without the internal solenoid are presented. A Langmuir probe located 27 cm axially outside of the plasma gun anode measures a bell-like radial ne profile with peak ne 1018 m-3 and Te 2 - 10 eV. Observed spectral lines of impurity ions provide an estimate of Te, and Balmer series line ratios of the main ion component are used to evaluate ne at both the probe location and near the plasma gun anode. A calorimeter measures the plasma flux to be constant and equivalent to 1 kA.

  18. Gun-Control Legislation and the Impact on Suicide.

    PubMed

    Leenaars, Antoon A

    2007-01-01

    Gun control is the prototypical example of controlling the environment for the means of suicide, an effective public health approach to suicide prevention. Canada's Criminal Law Amendment Act of 1977 (Bill C-51) provides an excellent opportunity to illustrate the effects of legislative gun-control laws and the impact on suicide. The research in Canada supports the significant effect of C-51 in reducing suicides and firearm suicides, even if one controls for socioeconomic factors, although not equally for all ages. The young, a high-risk group, show the most significant decrease, without significant substitution of other methods (displacement). Studies on gun-control laws from New Zealand, the United States, and Australia support the Canadian findings. It is concluded that, although not equally applicable in all countries, gun control may well have significant applications in reducing suicide worldwide.

  19. New light-gas guns for studying high-velocity impact at space velocities

    NASA Astrophysics Data System (ADS)

    Khristenko, Yuri F.

    2017-10-01

    The paper describes new light-gas guns for the high-velocity throwing of different projectiles: an upgraded two-stage light-gas powder gun and single-, two- and three-stage compressed light-gas guns. The paper also provides the schemes, pictures and characteristics of light-gas guns.

  20. Guns and Fear: A One-Way Street?

    ERIC Educational Resources Information Center

    Hauser, Will; Kleck, Gary

    2013-01-01

    Surveys show that more than one half of gun owners report owning their firearm for self-protection. Although research has examined the effect of fear of crime on gun ownership, the issue of reciprocity and temporal order has been largely ignored. Furthermore, the effect of firearm acquisition and relinquishment on fear has not been evaluated…

  1. Gun Violence and Children: Factors Related To Exposure and Trauma.

    ERIC Educational Resources Information Center

    Slovak, Karen

    2002-01-01

    Study investigated relationship between access to firearms and parental monitoring on rural youths' exposure to gun violence, and examined the effect of gun violence exposure on mental health. Results indicated a substantial number were exposed to gun violence. Exposure was related to firearm access and parental monitoring. Implications for social…

  2. Modifications Of A Commercial Spray Gun

    NASA Technical Reports Server (NTRS)

    Allen, Peter B.

    1993-01-01

    Commercial spray gun modified to increase spray rate and make sprayed coats more nearly uniform. Consists of gun head and pneumatic actuator. Actuator opens valves for two chemical components, called "A" and "B," that react to produce foam. Components flow through orifices, into mixing chamber in head. Mixture then flows through control orifice to spray tip. New spray tip tapered to reduce area available for accumulation of foam and makes tip easier to clean.

  3. From gunstore to smoking gun: tracking guns that kill children in North Carolina.

    PubMed

    Campbell, Brendan T; Radisch, Deborah L; Phillips, J Duncan; von Allmen, Daniel

    2004-12-01

    This study reviews the epidemiology of pediatric firearm deaths in North Carolina and estimates the time from the retail sale of guns to their involvement in pediatric firearm deaths. The authors reviewed autopsy reports for all children 0 to 14 years of age that died of firearm-related injuries in North Carolina from January 1999 through December 2002. Data obtained included demographic information, firearm type, and manner of death. Data from the Bureau of Alcohol, Tobacco and Firearms, which traced guns involved in crimes and determined the time elapsed from purchase to their involvement in a crime (ie, time-to-crime were also reviewed). During the study period, 40 children died of firearm injuries. Mean age was 7.6 years. Handguns were responsible for the majority of deaths (59%) followed by shotguns (27%), rifles (10%), and undetermined cause (10%). Most deaths were homicides (67%) followed by unintentional death (18%), suicide (13%), and undetermined cause (2%). Most crime guns (76%) were purchased legally, and many (40%) had a time-to-crime of less than 3 years. Legally purchased firearms pose a significant threat to children in North Carolina. A more restrictive approach to the sale of handguns is a logical approach to reducing pediatric firearm-related deaths in the United States.

  4. Coaxial-gun design and testing for the PLX- α Project

    NASA Astrophysics Data System (ADS)

    Witherspoon, F. Douglas; Brockington, Samuel; Case, Andrew; Cruz, Edward; Luna, Marco; Langendorf, Samuel

    2016-10-01

    We describe the Alpha coaxial gun designed for a 60-gun scaling study of spherically imploding plasma liners as a standoff driver for plasma-jet-driven magneto-inertial fusion (PJMIF). The guns operate over a range of parameters: 0.5-5.0 mg of Ar, Ne, N2, Kr, and Xe; 20-60 km/s; 2 × 1016 cm-3 muzzle density; and up to 7.5 kJ stored energy per gun. Each coaxial gun incorporates a fast dense gas injection and triggering system, a compact low-weight pfn with integral sparkgap switching, and a contoured gap designed to suppress the blow-by instability. The latest design iteration incorporates a faster more robust gas valve, an improved electrode contour, a custom 600- μF, 5-kV pfn, and six inline sparkgap switches operated in parallel. The switch and pfn are mounted directly to the back of the gun and are designed to reduce inductance, cost, and complexity, maximize efficiency and system reliability, and ensure symmetric current flow. We provide a brief overview of the design choices, the projected performance over the parameter ranges mentioned above, and experimental results from testing of the PLX- α coaxial gun. This work supported by the ARPA-E ALPHA Program.

  5. 27 CFR 478.36 - Transfer or possession of machine guns.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... machine guns. 478.36 Section 478.36 Alcohol, Tobacco Products, and Firearms BUREAU OF ALCOHOL, TOBACCO... Administrative and Miscellaneous Provisions § 478.36 Transfer or possession of machine guns. No person shall transfer or possess a machine gun except: (a) A transfer to or by, or possession by or under the authority...

  6. 27 CFR 478.36 - Transfer or possession of machine guns.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... machine guns. 478.36 Section 478.36 Alcohol, Tobacco Products, and Firearms BUREAU OF ALCOHOL, TOBACCO... Administrative and Miscellaneous Provisions § 478.36 Transfer or possession of machine guns. No person shall transfer or possess a machine gun except: (a) A transfer to or by, or possession by or under the authority...

  7. 27 CFR 478.36 - Transfer or possession of machine guns.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... machine guns. 478.36 Section 478.36 Alcohol, Tobacco Products, and Firearms BUREAU OF ALCOHOL, TOBACCO... Administrative and Miscellaneous Provisions § 478.36 Transfer or possession of machine guns. No person shall transfer or possess a machine gun except: (a) A transfer to or by, or possession by or under the authority...

  8. 27 CFR 478.36 - Transfer or possession of machine guns.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... machine guns. 478.36 Section 478.36 Alcohol, Tobacco Products, and Firearms BUREAU OF ALCOHOL, TOBACCO... Administrative and Miscellaneous Provisions § 478.36 Transfer or possession of machine guns. No person shall transfer or possess a machine gun except: (a) A transfer to or by, or possession by or under the authority...

  9. 27 CFR 478.36 - Transfer or possession of machine guns.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... machine guns. 478.36 Section 478.36 Alcohol, Tobacco Products, and Firearms BUREAU OF ALCOHOL, TOBACCO... Administrative and Miscellaneous Provisions § 478.36 Transfer or possession of machine guns. No person shall transfer or possess a machine gun except: (a) A transfer to or by, or possession by or under the authority...

  10. 46 CFR 160.031-4 - Equipment for shoulder gun type line-throwing appliance.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 6 2014-10-01 2014-10-01 false Equipment for shoulder gun type line-throwing appliance... Appliance, Shoulder Gun Type (and Equipment) § 160.031-4 Equipment for shoulder gun type line-throwing... the gun. The line canister shall be secured by clamps or brackets below the barrel of the gun. (c) One...

  11. 46 CFR 160.031-4 - Equipment for shoulder gun type line-throwing appliance.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 6 2010-10-01 2010-10-01 false Equipment for shoulder gun type line-throwing appliance... Appliance, Shoulder Gun Type (and Equipment) § 160.031-4 Equipment for shoulder gun type line-throwing... the gun. The line canister shall be secured by clamps or brackets below the barrel of the gun. (c) One...

  12. 46 CFR 160.031-4 - Equipment for shoulder gun type line-throwing appliance.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 6 2013-10-01 2013-10-01 false Equipment for shoulder gun type line-throwing appliance... Appliance, Shoulder Gun Type (and Equipment) § 160.031-4 Equipment for shoulder gun type line-throwing... the gun. The line canister shall be secured by clamps or brackets below the barrel of the gun. (c) One...

  13. 46 CFR 160.031-4 - Equipment for shoulder gun type line-throwing appliance.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 6 2012-10-01 2012-10-01 false Equipment for shoulder gun type line-throwing appliance... Appliance, Shoulder Gun Type (and Equipment) § 160.031-4 Equipment for shoulder gun type line-throwing... the gun. The line canister shall be secured by clamps or brackets below the barrel of the gun. (c) One...

  14. 46 CFR 160.031-4 - Equipment for shoulder gun type line-throwing appliance.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 6 2011-10-01 2011-10-01 false Equipment for shoulder gun type line-throwing appliance... Appliance, Shoulder Gun Type (and Equipment) § 160.031-4 Equipment for shoulder gun type line-throwing... the gun. The line canister shall be secured by clamps or brackets below the barrel of the gun. (c) One...

  15. Outdoor air pollution in close proximity to a continuous point source

    NASA Astrophysics Data System (ADS)

    Klepeis, Neil E.; Gabel, Etienne B.; Ott, Wayne R.; Switzer, Paul

    Data are lacking on human exposure to air pollutants occurring in ground-level outdoor environments within a few meters of point sources. To better understand outdoor exposure to tobacco smoke from cigarettes or cigars, and exposure to other types of outdoor point sources, we performed more than 100 controlled outdoor monitoring experiments on a backyard residential patio in which we released pure carbon monoxide (CO) as a tracer gas for continuous time periods lasting 0.5-2 h. The CO was emitted from a single outlet at a fixed per-experiment rate of 120-400 cc min -1 (˜140-450 mg min -1). We measured CO concentrations every 15 s at up to 36 points around the source along orthogonal axes. The CO sensors were positioned at standing or sitting breathing heights of 2-5 ft (up to 1.5 ft above and below the source) and at horizontal distances of 0.25-2 m. We simultaneously measured real-time air speed, wind direction, relative humidity, and temperature at single points on the patio. The ground-level air speeds on the patio were similar to those we measured during a survey of 26 outdoor patio locations in 5 nearby towns. The CO data exhibited a well-defined proximity effect similar to the indoor proximity effect reported in the literature. Average concentrations were approximately inversely proportional to distance. Average CO levels were approximately proportional to source strength, supporting generalization of our results to different source strengths. For example, we predict a cigarette smoker would cause average fine particle levels of approximately 70-110 μg m -3 at horizontal distances of 0.25-0.5 m. We also found that average CO concentrations rose significantly as average air speed decreased. We fit a multiplicative regression model to the empirical data that predicts outdoor concentrations as a function of source emission rate, source-receptor distance, air speed and wind direction. The model described the data reasonably well, accounting for ˜50% of the log

  16. Automated Chromium Plating Line for Gun Barrels

    DTIC Science & Technology

    1979-09-01

    consistent pretreatments and bath dwell times. Some of the advantages of automated processing include increased productivity (average of 20^) due to...when automated processing procedures’ are used. The current method of applying chromium electrodeposits to gun tubes is a manual, batch operation...currently practiced with rotary swaged gun tubes would substantially reduce the difficulties in automated processing . RECOMMENDATIONS

  17. Should Gun Safety Be Taught in Schools? Perspectives of Teachers

    ERIC Educational Resources Information Center

    Obeng, Cecilia

    2010-01-01

    Background: Gun-related injuries and deaths among children occur at disproportionately high rates in the United States. Children who live in homes with guns are the most likely victims. This study describes teachers' views on whether gun safety should be taught to children in the preschool and elementary years. Methods: A total of 150 survey…

  18. The US gun stock: results from the 2004 national firearms survey

    PubMed Central

    Hepburn, L; Miller, M; Azrael, D; Hemenway, D

    2007-01-01

    Objectives To examine the size and composition of the privately held firearm stock in the US; and to describe demographic patterns of firearm ownership and motivations for ownership. Design, setting and participants A nationally representative household telephone survey of 2770 adults aged ⩾18 years living in the US, conducted in the spring of 2004. Main outcome measure Responses to questions regarding firearm ownership, the number and types of guns owned, and motivations for ownership. Results 38% of households and 26% of individuals reported owning at least one firearm. This corresponds to 42 million US households with firearms, and 57 million adult gun owners. 64% of gun owners or 16% of American adults reported owning at least one handgun. Long guns represent 60% of the privately held gun stock. Almost half (48%) of all individual gun owners reported owning ⩾4 firearms. Men more often reported firearm ownership, with 45% stating that they personally owned at least one firearm, compared with 11% for women. Conclusions The US population continues to contain at least one firearm for every adult, and ownership is becoming increasingly concentrated. Long guns are the most prevalent type of gun in the US but handgun ownership is widespread. Ownership demographic patterns support findings of previous studies. PMID:17296683

  19. Gun Testing Ballistics Issues for Insensitive Munitions Fragment Impact Testing

    NASA Astrophysics Data System (ADS)

    Baker, Ernest; Schultz, Emmanuel; NATO Munitions Safety Information Analysis Centre Team

    2017-06-01

    The STANAG 4496 Ed. 1 Fragment Impact, Munitions Test Procedure is normally conducted by gun launching a projectile for attack against a munition. The purpose of this test is to assess the reaction of a munition impacted by a fragment. The test specifies a standardized projectile (fragment) with a standard test velocity of 2530+/-90 m/s, or an alternate test velocity of 1830+/-60 m/s. The standard test velocity can be challenging to achieve and has several loosely defined and undefined characteristics that can affect the test item response. This publication documents the results of an international review of the STANAG 4496 related to the fragment impact test. To perform the review, MSIAC created a questionnaire in conjunction with the custodian of this STANAG and sent it to test centers. Fragment velocity variation, projectile tilt upon impact and aim point variation were identified as observed gun testing issues. Achieving 2530 m/s consistently and cost effectively can be challenging. The aim point of impact of the fragment is chosen with the objective of obtaining the most violent reaction. No tolerance for aim point is specified, although aim point variation can be a source for IM response variation. Fragment tilt on impact is also unspecified. The standard fragment fabricated from a variety of different steels which have a significant margin for mechanical properties. These, as well as other gun testing issues, have significant implications to resulting IM response.

  20. Performance of a first generation X-band photoelectron rf gun

    DOE PAGES

    Limborg-Deprey, C.; Adolphsen, C.; McCormick, D.; ...

    2016-05-04

    Building more compact accelerators to deliver high brightness electron beams for the generation of high flux, highly coherent radiation is a priority for the photon science community. A relatively straightforward reduction in footprint can be achieved by using high-gradient X-band (11.4 GHz) rf technology. To this end, an X-band injector consisting of a 5.5 cell rf gun and a 1-m long linac has been commissioned at SLAC. It delivers an 85 MeV electron beam with peak brightness somewhat better than that achieved in S-band photoinjectors, such as the one developed for the Linac Coherent Light Source (LCLS). The X-band rfmore » gun operates with up to a 200 MV/m peak field on the cathode, and has been used to produce bunches of a few pC to 1.2 nC in charge. Notably, bunch lengths as short as 120 fs rms have been measured for charges of 5 pC (~3×10 7 electrons), and normalized transverse emittances as small as 0.22 mm-mrad have been measured for this same charge level. Bunch lengths as short as 400 (250) fs rms have been achieved for electron bunches of 100 (20) pC with transverse normalized emittances of 0.7 (0.35) mm-mrad. As a result, we report on the performance and the lessons learned from the operation and optimization of this first generation X-band gun.« less

  1. Performance of a first generation X-band photoelectron rf gun

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Limborg-Deprey, C.; Adolphsen, C.; McCormick, D.

    Building more compact accelerators to deliver high brightness electron beams for the generation of high flux, highly coherent radiation is a priority for the photon science community. A relatively straightforward reduction in footprint can be achieved by using high-gradient X-band (11.4 GHz) rf technology. To this end, an X-band injector consisting of a 5.5 cell rf gun and a 1-m long linac has been commissioned at SLAC. It delivers an 85 MeV electron beam with peak brightness somewhat better than that achieved in S-band photoinjectors, such as the one developed for the Linac Coherent Light Source (LCLS). The X-band rfmore » gun operates with up to a 200 MV/m peak field on the cathode, and has been used to produce bunches of a few pC to 1.2 nC in charge. Notably, bunch lengths as short as 120 fs rms have been measured for charges of 5 pC (~3×10 7 electrons), and normalized transverse emittances as small as 0.22 mm-mrad have been measured for this same charge level. Bunch lengths as short as 400 (250) fs rms have been achieved for electron bunches of 100 (20) pC with transverse normalized emittances of 0.7 (0.35) mm-mrad. As a result, we report on the performance and the lessons learned from the operation and optimization of this first generation X-band gun.« less

  2. Examining the relationship between the prevalence of guns and homicide rates in the USA using a new and improved state-level gun ownership proxy.

    PubMed

    Siegel, Michael; Ross, Craig S; King, Charles

    2014-12-01

    Determining the relationship between gun ownership levels and firearm homicide rates is critical to inform public health policy. Previous research has shown that state-level gun ownership, as measured by a widely used proxy, is positively associated with firearm homicide rates. A newly developed proxy measure that incorporates the hunting license rate in addition to the proportion of firearm suicides correlates more highly with state-level gun ownership. To corroborate previous research, we used this new proxy to estimate the association of state-level gun ownership with total, firearm, and non-firearm homicides. Using state-specific data for the years 1981-2010, we modelled these rates as a function of gun ownership level, controlling for potential confounding factors. We used a negative binomial regression model and accounted for clustering of observations among states. We found that state-level gun ownership as measured by the new proxy, is significantly associated with firearm and total homicides but not with non-firearm homicides. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  3. Frequency of Guns in the Households of High School Seniors

    ERIC Educational Resources Information Center

    Coker, Ann L.; Bush, Heather M.; Follingstad, Diane R.; Brancato, Candace J.

    2017-01-01

    Background: In 2013, President Obama lifted the federal ban on gun violence research. The current study provides one of the first reports to estimate household gun ownership as reported by youth. Methods: In this cohort study of 3,006 high school seniors from 24 schools, we examined the frequency of household guns ownership. Results: About 65%…

  4. Spatio-temporal patterns of gun violence in Syracuse, New York 2009-2015.

    PubMed

    Larsen, David A; Lane, Sandra; Jennings-Bey, Timothy; Haygood-El, Arnett; Brundage, Kim; Rubinstein, Robert A

    2017-01-01

    Gun violence in the United States of America is a large public health problem that disproportionately affects urban areas. The epidemiology of gun violence reflects various aspects of an infectious disease including spatial and temporal clustering. We examined the spatial and temporal trends of gun violence in Syracuse, New York, a city of 145,000. We used a spatial scan statistic to reveal spatio-temporal clusters of gunshots investigated and corroborated by Syracuse City Police Department for the years 2009-2015. We also examined predictors of areas with increased gun violence using a multi-level zero-inflated Poisson regression with data from the 2010 census. Two space-time clusters of gun violence were revealed in the city. Higher rates of segregation, poverty and the summer months were all associated with increased risk of gun violence. Previous gunshots in the area were associated with a 26.8% increase in the risk of gun violence. Gun violence in Syracuse, NY is both spatially and temporally stable, with some neighborhoods of the city greatly afflicted.

  5. Spatio-temporal patterns of gun violence in Syracuse, New York 2009-2015

    PubMed Central

    Lane, Sandra; Jennings-Bey, Timothy; Haygood-El, Arnett; Brundage, Kim; Rubinstein, Robert A.

    2017-01-01

    Gun violence in the United States of America is a large public health problem that disproportionately affects urban areas. The epidemiology of gun violence reflects various aspects of an infectious disease including spatial and temporal clustering. We examined the spatial and temporal trends of gun violence in Syracuse, New York, a city of 145,000. We used a spatial scan statistic to reveal spatio-temporal clusters of gunshots investigated and corroborated by Syracuse City Police Department for the years 2009–2015. We also examined predictors of areas with increased gun violence using a multi-level zero-inflated Poisson regression with data from the 2010 census. Two space-time clusters of gun violence were revealed in the city. Higher rates of segregation, poverty and the summer months were all associated with increased risk of gun violence. Previous gunshots in the area were associated with a 26.8% increase in the risk of gun violence. Gun violence in Syracuse, NY is both spatially and temporally stable, with some neighborhoods of the city greatly afflicted. PMID:28319125

  6. Finite element analyses of a linear-accelerator electron gun

    NASA Astrophysics Data System (ADS)

    Iqbal, M.; Wasy, A.; Islam, G. U.; Zhou, Z.

    2014-02-01

    Thermo-structural analyses of the Beijing Electron-Positron Collider (BEPCII) linear-accelerator, electron gun, were performed for the gun operating with the cathode at 1000 °C. The gun was modeled in computer aided three-dimensional interactive application for finite element analyses through ANSYS workbench. This was followed by simulations using the SLAC electron beam trajectory program EGUN for beam optics analyses. The simulations were compared with experimental results of the assembly to verify its beam parameters under the same boundary conditions. Simulation and test results were found to be in good agreement and hence confirmed the design parameters under the defined operating temperature. The gun is operating continuously since commissioning without any thermal induced failures for the BEPCII linear accelerator.

  7. Finite element analyses of a linear-accelerator electron gun.

    PubMed

    Iqbal, M; Wasy, A; Islam, G U; Zhou, Z

    2014-02-01

    Thermo-structural analyses of the Beijing Electron-Positron Collider (BEPCII) linear-accelerator, electron gun, were performed for the gun operating with the cathode at 1000 °C. The gun was modeled in computer aided three-dimensional interactive application for finite element analyses through ANSYS workbench. This was followed by simulations using the SLAC electron beam trajectory program EGUN for beam optics analyses. The simulations were compared with experimental results of the assembly to verify its beam parameters under the same boundary conditions. Simulation and test results were found to be in good agreement and hence confirmed the design parameters under the defined operating temperature. The gun is operating continuously since commissioning without any thermal induced failures for the BEPCII linear accelerator.

  8. Lung cancer and air pollution.

    PubMed

    Aoki, K; Shimizu, H

    1977-12-01

    The relationship between incidence of lung cancer and the volume of traffic as indicated by auto exhaust concentration was examined; the results, though suggestive, did not yield consistent evidence of the association between them. Traffic jams in Nagoya began 15 years ago, a period that may not be long enough to provide definitive data on the incidence of lung cancer. The high standardized mortality ratio (SMR) of lung cancer was observed in cities with a population of less than 1 million and guns (rural areas) along the coast, although those in the metropolitan areas with populations of more than 1 million were average. The SMR did not correlate with various socioeconomic conditions and industrial air pollution. Meteorologic or geologic conditions and ocean currents were not associated with SMR of lung cancer by city and gun. The population of a gun or of some cities was not large enough to be statistically significant, and the mortality rate of lung cancer was not always stable.

  9. Back-trajectory modeling of high time-resolution air measurement data to separate nearby sources

    EPA Science Inventory

    Strategies to isolate air pollution contributions from sources is of interest as voluntary or regulatory measures are undertaken to reduce air pollution. When different sources are located in close proximity to one another and have similar emissions, separating source emissions ...

  10. Energy partitioning in an inductively driven rail gun

    NASA Technical Reports Server (NTRS)

    Sen, K. K.; Ray, P. K.

    1984-01-01

    The equations describing the performance of an inductively driven rail are analyzed numerically. Friction between the projectile and rails is included through an empirical formulation. The equations are applied to the experiment of Rashleigh and Marshall to obtain an estimate of energy distribution in rail guns as a function of time. It is found that only 15 percent of energy delivered by the inductor to the gun is transformed into the kinetic energy of the projectile. This study provides an insight into the nature of nonlinear coupling involved in the electromechanical interactions in a rail gun.

  11. The Baltimore Youth Ammunition Initiative: A Model Application of Local Public Health Authority in Preventing Gun Violence

    PubMed Central

    Lewin, Nancy L.; Vernick, Jon S.; Beilenson, Peter L.; Mair, Julie S.; Lindamood, Melisa M.; Teret, Stephen P.; Webster, Daniel W.

    2005-01-01

    In 2002, the Baltimore City Health Department, in collaboration with the Baltimore Police Department and the Johns Hopkins Center for Gun Policy and Research, launched the Youth Ammunition Initiative. The initiative addressed Baltimore’s problem of youth gun violence by targeting illegal firearm ammunition sales to the city’s young people. The initiative included undercover “sting” investigations of local businesses and issuance of health department violation and abatement notices. Intermediate results included the passage of 2 Baltimore city council ordinances regulating ammunition sales and reducing the number of outlets eligible to sell ammunition. Although it is too early to assess effects on violent crime, the intervention could theoretically reduce youth violence by interrupting one source of ammunition to youths. More important, the initiative can serve as a policy model for health commissioners seeking to become more active in gun violence prevention efforts. PMID:15855448

  12. The Transmission of Gun and Other Weapon-Involved Violence Within Social Networks

    PubMed Central

    Tracy, Melissa; Braga, Anthony A.; Papachristos, Andrew V.

    2016-01-01

    Fatal and nonfatal injuries resulting from gun violence remain a persistent problem in the United States. The available research suggests that gun violence diffuses among people and across places through social relationships. Understanding the relationship between gun violence within social networks and individual gun violence risk is critical in preventing the spread of gun violence within populations. This systematic review examines the existing scientific evidence on the transmission of gun and other weapon-related violence in household, intimate partner, peer, and co-offending networks. Our review identified 16 studies published between 1996 and 2015 that suggest that exposure to a victim or perpetrator of violence in one's interpersonal relationships and social networks increases the risk of individual victimization and perpetration. Formal network analyses find high concentrations of gun violence in small networks and that exposure to gun violence in one's networks is highly correlated with one's own probability of being a gunshot victim. Physical violence by parents and weapon use by intimate partners also increase risk for victimization and perpetration. Additional work is needed to better characterize the mechanisms through which network exposures increase individual risk for violence and to evaluate interventions aimed at disrupting the spread of gun and other weapon violence in high-risk social networks. PMID:26733492

  13. College Students Opinions on Gun Violence.

    PubMed

    Lewis, Rhonda K; LoCurto, Jamie; Brown, Kyrah; Stowell, David; Maryman, J'Vonnah; Dean, Amber; McNair, Thoi; Ojeda, Debbie; Siwierka, Julia

    2016-06-01

    Gun violence and control issues have become serious public health problems. This study gathered the opinions from 419 college students from a Midwestern University. Participants were asked about beliefs about purchasing assault weapons, beliefs about bringing handguns to college campuses and beliefs about contributing factors that lead to gun violence. Participants completed surveys online. The findings showed that overall 54 % of respondents believed that military assault weapons should be banned and 53 % agree that teachers should be allowed to carry a registered handgun on campus. There were statistically significant differences between males and females on these issues. For instance, females believed military assault weapons and high capacity magazines should be banned more than 1.9 times (p = .004) p < .05 compared to male students. On the other hand, female students were more likely to believe that school teachers should be allowed to carry registered handguns on school campuses more than 1.55 times (p = .046) p < .05 compared to their male student counterparts. There were no statistically significant differences between ethnic groups. The top four contributing factors that students believed led to gun violence were decline in parenting and family values (17 %), gang involvement (14 %), bullying (13.8 %) and guns being easy to obtain (13.8 %). Limitations and implications for policy work are discussed.

  14. Selling a gun to a stranger without a background check: acceptable behaviour?

    PubMed

    Hemenway, David; Azrael, Deborah; Miller, Matthew

    2018-06-01

    One way that guns get into the wrong hands is via gun sales without a background check. While the large majority of Americans support laws requiring universal background checks, no prior study has assessed whether Americans think it is acceptable behaviour to sell a gun to a stranger without a background check, whether or not there is a law against it. We sponsored a nationally representative survey of over 3900 American adults, oversampling gun owners, using an online panel provided by the survey firm Growth for Knowledge. Over 72% of American adults agree or strongly agree with the statement that 'whether it is legal or not, it is NOT acceptable to sell a gun to a stranger without a background check' and 11% disagree or strongly disagree. Subgroups less likely to agree are young adults, men, conservatives, those with less than a high school education and gun owners. Reducing the number of guns sold without a background check could help reduce the flow of guns to felons. Changes in normative attitudes and behaviours, as well as changes in law, could help accomplish this goal. Most Americans, including gun owners, believe selling a gun to a stranger without a background check is not acceptable behaviour. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  15. Characterization of outdoor air particles as source of impurities in supply air

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pasanen, P.; Kalliokoski, P.; Tuomainen, A.

    1997-12-31

    Odor emission of supply air filters has proved to be a major source of stuffy odor of supply air. In this study, the odor emission characteristics of outdoor air particles and odor emissions of coarse prefilters and fine filters were studied. The outdoor air samples were collected by the aid of high volume impactor. Odor emissions of the size fractions, < 2.1 {micro}m , 2.1--10 {micro}m and >10 {micro}m were studied separately in laboratory with a trained olf panel: The odor emissions of the ventilation filters in real use were evaluated five times during the 14 month study period. Aftermore » the field evaluation the emissions of carbonyl compounds and other volatile organic compounds. The odor emissions of outdoor air particles were the highest during the heating season and lowest in the summer. The particles in the coarsest fraction had the most abundant emissions (1,200 olf/g) while the emissions from fine particles were lowest (100 olf/g). The odor emissions evaluated from the coarse and fine ventilation filters supported the finding that particles collected on coarse prefilter had the most abundant odor emission.« less

  16. Air pollution sources and childhood asthma attacks in Catano, Puerto Rico.

    PubMed

    Loyo-Berríos, Nilsa I; Irizarry, Rafael; Hennessey, Joseph G; Tao, Xuguang Grant; Matanoski, Genevieve

    2007-04-15

    Asthma prevalence in the Cataño Air Basin of Puerto Rico is 27% for children aged 13-14 years and 45% for children aged 5-6 years. There is concern that these rates are related to air pollution. The authors conducted a nested case-control study to evaluate whether proximity to air pollution point sources was associated with increased risk of asthma attacks. For 1997-2001, 1,382 asthma-related medical visits (International Classification of Diseases, Ninth Revision, codes 493 and 493.9) in children under 17 were identified through health insurance claims. Controls were children with no asthma attacks who were randomly selected from enrollees in two health insurance companies by incidence density sampling (1:5) and matched to cases on gender, age, insurance company, and event date. The distance from a point source to the subject's residence area represented a surrogate exposure measurement. Odds ratios for a 1-km decrease in distance were obtained by conditional logistic regression. Risk of asthma attack was associated with residing near a grain mill (odds ratio (OR) = 1.35), petroleum refinery (OR = 1.44), asphalt plant (OR = 1.23), or power plant (OR = 1.28) (all p's < 0.05). Residence near major air emissions sources (>100 tons/year) increased asthma attack risk by 108% (p < 0.05). These results showed that proximity to some air pollution sources is associated with increased risks of asthma attacks.

  17. Parallel 3D Finite Element Numerical Modelling of DC Electron Guns

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Prudencio, E.; Candel, A.; Ge, L.

    2008-02-04

    In this paper we present Gun3P, a parallel 3D finite element application that the Advanced Computations Department at the Stanford Linear Accelerator Center is developing for the analysis of beam formation in DC guns and beam transport in klystrons. Gun3P is targeted specially to complex geometries that cannot be described by 2D models and cannot be easily handled by finite difference discretizations. Its parallel capability allows simulations with more accuracy and less processing time than packages currently available. We present simulation results for the L-band Sheet Beam Klystron DC gun, in which case Gun3P is able to reduce simulation timemore » from days to some hours.« less

  18. Low-energy plasma-cathode electron gun with a perforated emission electrode

    NASA Astrophysics Data System (ADS)

    Burdovitsin, Victor; Kazakov, Andrey; Medovnik, Alexander; Oks, Efim; Tyunkov, Andrey

    2017-11-01

    We describe research of influence of the geometric parameters of perforated electrode on emission parameters of a plasma cathode electron gun generating continuous electron beams at gas pressure 5-6 Pa. It is shown, that the emission current increases with increasing the hole diameters and decreasing the thickness of the perforated emission electrode. Plasma-cathode gun with perforated electron can provide electron extraction with an efficiency of up to 72 %. It is shown, that the current-voltage characteristic of the electron gun with a perforated emission electrode differs from that of similar guns with fine mesh grid electrode. The plasma-cathode electron gun with perforated emission electrode is used for electron beam welding and sintering.

  19. The Air Force Handbook 2007

    DTIC Science & Technology

    2007-01-01

    sPEcIfIcATIOns Weight 51,000 lb. (22,950 kg ) Range 800 miles (695 nautical miles) Armament One 30 mm GAU-8/A seven-barrel Gatling gun with over 1,150...battlefield air and space profession- als who bring unequaled accuracy, responsiveness, flexibility, and persistence to the Joint warfight. LOSS Of...approximately $12.4 billion. This loss of buying power reduced Air Force Program content by an additional $10 billion per year. Base Realignment

  20. Effect of Gun Carrying on Perceptions of Risk Among Adolescent Offenders.

    PubMed

    Loughran, Thomas A; Reid, Joan A; Collins, Megan Eileen; Mulvey, Edward P

    2016-02-01

    We observed how perceptions of risks, costs, crime rewards, and violence exposure change as individual gun-carrying behavior changes among high-risk adolescents. We analyzed a longitudinal study (2000-2010) of serious juvenile offenders in Maricopa County, Arizona, or Philadelphia County, Pennsylvania, assessing within-person changes in risk and reward perceptions, and violence exposure as individuals initiated or ceased gun carrying. Despite being associated with heightened exposure to violence, gun carrying was linked to lower perceptions of risks and costs and higher perceived rewards of offending. Gun carrying was not time-stable, as certain individuals both started and stopped carrying during the study. Within-person changes in carrying guns were associated with shifting perceptions of risks, costs, and rewards of crime, and changes in exposure to violence in expected directions. Gun carrying reduces perceptions of risks associated with offending while increasing actual risk of violence exposure. This suggests that there is an important disconnect between perceptions and objective levels of safety among high-risk youths. Gun-carrying decisions may not only be influenced by factors of protection and self-defense, but also by perceptions of risks and reward associated with engaging in crime more generally.

  1. Hand injury with a nail gun: a case report with literature review.

    PubMed

    Boya, Hakan; Uzun, Belkan

    2015-01-01

    The nail gun was introduced in the late 1950s to increase the ease of driving nails, studs, bolts, or staples into various hard surfaces. The nail gun is a potentially dangerous device that is still commonly used in the construction industry. Since its introduction, an increasing number of studies have reported injuries associated with nail guns. Nail gun-related injuries-such as to the head, neck, and chest-can be devastating, and in some cases, even fatal. Extremity injuries, notably in the hand, can cause loss of function, missed work, and long-term health effects. This case report describes a nail-gun injury of the hand along with a discussion of the unique features of and treatment strategies for nail gun injuries.

  2. High-perveance W-band Sheet-beam Electron Gun Design

    DTIC Science & Technology

    2008-04-01

    APR 2008 2. REPORT TYPE 3. DATES COVERED 00-00-2008 to 00-00-2008 4. TITLE AND SUBTITLE High -perveance W- band Sheet-beam Electron Gun Design 5a...8-98) Prescribed by ANSI Std Z39-18 10.1: High -perveance W- band Sheet-beam Electron Gun Design Khanh T. Nguyen1, John Pasour, Edward L. Wright1...effects due to cathode temperature are also included in the simulation. Keywords: Sheet beam; W- band ; electron gun; high perveance; amplifiers

  3. Thermal analysis of electron gun for travelling wave tubes

    NASA Astrophysics Data System (ADS)

    Bhat, K. S.; Sreedevi, K.; Ravi, M.

    2006-11-01

    Thermal analysis of a pierce type electron gun using the FEM software ANSYS and its experimental validation are presented in this paper. Thermal analysis of the electron gun structure has been carried out to find out the effect of heater power on steady state temperature and warm-up time. The thermal drain of the supporting structure has also been analyzed for different materials. These results were experimentally verified in an electron gun. The experimental results closely match the ANSYS results.

  4. Near-source air quality assessment: challenges and collaboration

    EPA Science Inventory

    This presentation is to give a general overview of near-source air pollution concerns and recent EPA projects (near-road, near-rail, near-port), as well as explaining how these projects were implemented through collaboration internally and externally.

  5. Gated Field-Emission Cathode Radio-Frequency (RF) Gun

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fermi Research Alliance, Fermi Alliance

    The goal of this CRADA was to procure the carbon nanotube cathode from Radiabeam, install it in HBESL and make current measurements as a function of the gun gradient. The gun was operated at 1.3 GHz. After testing, send the cathode back to RadiaBeam for surface analysis.

  6. Construction and Test of a Novel Superconducting RF Electron gun

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bisognano, Joseph J.

    The University of Wisconsin-Madison has completed installation of a superconducting electron gun. Its concept was optimized to be the source for a CW free electron laser facility with multiple megahertz repetition rate end stations. This VHF superconducting configuration holds the promise of the highest performance for CW injectors. Initial commissioning efforts show that the cavity can achieve gradients of 35 MV/m at the cathode position. With the cathode inserted CW operation has been achieved at 20 MV/m with good control of microphonics, negligible dark current, and Q0 > 3×109 at 4 K. Bunch charges of ~100 pC have been delivered,more » and first simple beam measurements made. These preliminary results are very encouraging for production of 100s pC bunches with millimeter-milliradian or smaller normalized emittances. Plans are in place to carry out more definitive studies to establish the full capabilities. However, since the grant was not renewed, the electron gun is currently mothballed, and without supplemental fund the opportunity for further work will be lost.« less

  7. Firearm Retailers’ Willingness to Participate in an Illegal Gun Purchase

    PubMed Central

    2010-01-01

    Firearm-related violence is a significant public health and public safety problem for cities in the USA, and licensed firearm retailers are an important source of the guns used in that violence. Using a scripted telephone interview, we screened a sample of licensed retailers in California to assess their willingness to participate in the surrogate or “straw” purchase of a handgun; such purchases are illegal under federal law. Of 149 retailers who provided a response, 30 (20.1%) agreed to participate. In multivariate analysis, pawnbrokers were more likely to agree than were gun dealers (odds ratio 6.58, 95% confidence interval 1.99–21.71). Sales of handguns that were later subjected to ownership tracing (a proxy measure for a gun’s use in crime) were not more frequent among retailers who agreed to participate than among others, and other findings were unexpected as well. Electronic supplementary material The online version of this article (doi:10.1007/s11524-010-9489-6) contains supplementary material, which is available to authorized users. PMID:20803095

  8. Effect of low emission sources on air quality in Cracow

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nedoma, J.

    1995-12-31

    The paper presents calculation of power engineering low emission and results of stimulation of the effect of this emission on air quality in Cracow, Poland. It has been stated that the segment of low emission in central areas of the town makes up ca. 40% of the observed concentration of sulfur dioxide. Furthermore it has been stated that the capital investment must be concentrated in the central part of the town in order to reach noticeable improvement of air quality in Cracow. Neither the output of a separate power source nor the emission level and its individual harmful effect, butmore » the location of the source and especially packing density of the sources must decide the priority of upgrading actions.« less

  9. Gun Safety (For Parents)

    MedlinePlus

    ... Kids Teens How Media Use Affects Your Child School Violence and the News How to Talk to Your ... What Should I Do? Should You Worry About School Violence? Gun Safety Posttraumatic Stress Disorder View more About ...

  10. Ways to Increase Launch Velocities of 2-Stage Gas Guns

    NASA Technical Reports Server (NTRS)

    Bogdanoff, David W.; Cambier, Jean-Luc; Arnold, James O. (Technical Monitor)

    1994-01-01

    velocity can be obtained with multiple compressions in the pump tube. With a conventional two-stage gun, an important limitation to obtaining higher velocities is friction and heat transfer to the barrel, which typically has a length- to- diameter ratio of 200-400. These viscous losses greatly reduce the effectiveness of the regions of the barrel far removed from the second stage breech. We have studied computationally the effect of adding an additional breech (or breeches) along the barrel to reduce these viscous losses. Velocity increases from 6.5 to 7.2 km/sec have been obtained using the main breech and one additional breech. In these results, both breeches were operated with hydrogen, heated electrothermally. We have also studied a gun geometry where the main breech is operated in the conventional manner, using piston compression. The additional breech is operated either with electrothermal heating or heating by using a high explosive charge in a novel geometry. The latter option provides very effective compression, heating and acceleration of the hydrogen working gas and is fully reusable. Calculations are presented which show that very substantial increases in muzzle velocity can be obtained this way, without overstressing the projectile or the 'gun. The third technique studied is to add a section of ram accelerator tube after the barrel to further accelerate the projectile. The ram accelerator used here is not the conventional premixed gas ram accelerator, but a new technique using high explosive as the energy source and pure hydrogen as the working gas in a geometry which can be made fully reusable. Preliminary results with this new rain accelerator geometry were presented and showed that stable ram accelerator drive can be established. Herein, detailed calculations axe presented which show that substantial velocity increases can be obtained using this ram accelerator technique in tandem with a conventional light gas gun.

  11. The Origins of Gun Culture in the United States, 1760-1865.

    ERIC Educational Resources Information Center

    Bellesiles, Michael A.

    1996-01-01

    Maintains that, counter to popular opinion, guns played no significant role in U.S. frontier life until the Civil War era. Evidence from probate and militia records reveal a consistent lack of gun ownership while magazine articles painted unflattering portraits of gun ownership and hunting. Discusses reasons for the change. (MJP)

  12. Compact Electron Gun Based on Secondary Emission Through Ionic Bombardment

    PubMed Central

    Diop, Babacar; Bonnet, Jean; Schmid, Thomas; Mohamed, Ajmal

    2011-01-01

    We present a new compact electron gun based on the secondary emission through ionic bombardment principle. The driving parameters to develop such a gun are to obtain a quite small electron gun for an in-flight instrument performing Electron Beam Fluorescence measurements (EBF) on board of a reentry vehicle in the upper atmosphere. These measurements are useful to characterize the gas flow around the vehicle in terms of gas chemical composition, temperatures and velocity of the flow which usually presents thermo-chemical non-equilibrium. Such an instrument can also be employed to characterize the upper atmosphere if placed on another carrier like a balloon. In ground facilities, it appears as a more practical tool to characterize flows in wind tunnel studies or as an alternative to complex electron guns in industrial processes requiring an electron beam. We describe in this paper the gun which has been developed as well as its different features which have been characterized in the laboratory. PMID:22163896

  13. The synthesis method for design of electron flow sources

    NASA Astrophysics Data System (ADS)

    Alexahin, Yu I.; Molodozhenzev, A. Yu

    1997-01-01

    The synthesis method to design a relativistic magnetically - focused beam source is described in this paper. It allows to find a shape of electrodes necessary to produce laminar space charge flows. Electron guns with shielded cathodes designed with this method were analyzed using the EGUN code. The obtained results have shown the coincidence of the synthesis and analysis calculations [1]. This method of electron gun calculation may be applied for immersed electron flows - of interest for the EBIS electron gun design.

  14. Effects of Maryland's law banning Saturday night special handguns on crime guns

    PubMed Central

    Vernick, J.; Webster, D.; Hepburn, L.

    1999-01-01

    Objectives—To determine the effects of a 1988 Maryland law that banned "Saturday night special" handguns on the types of guns used in crime. To determine if controls on the lawful market for handguns affect the illegal market as well. Setting—Baltimore, Maryland, and 15 other US cities participating in a crime gun tracing project. Methods—Cross sectional comparison of the proportion of crime guns that are banned by the Maryland law, comparing Baltimore, MD with 15 other cities outside of Maryland. Multivariate linear regression analysis to determine if observed differences between Baltimore and 15 other cities are explained by demographic or regional differences among the cities rather than Maryland's law. Results—Among crime guns, a gun banned by Maryland's law is more than twice as likely (relative risk (RR) 2.3, 95% confidence interval (CI) 2.0 to 2.5) to be the subject of a crime gun trace request in 15 other cities combined, than in Baltimore. Among homicide guns, a crime especially relevant for public safety, a comparable difference (RR 2.1, 95% CI 1.1 to 4.2) was observed. The proportion of Baltimore's crime guns that are banned is 12 percentage points lower than would be expected based on its demographic and regional characteristics alone. Among crime guns purchased after 1990, a much smaller proportion in Baltimore are banned models than in 15 other cities. Conclusions—Maryland's law has reduced the use of banned Saturday night specials by criminals in Baltimore. Contrary to the claims of some opponents of gun control laws, regulation of the lawful market for firearms can also affect criminals. PMID:10628912

  15. The Transmission of Gun and Other Weapon-Involved Violence Within Social Networks.

    PubMed

    Tracy, Melissa; Braga, Anthony A; Papachristos, Andrew V

    2016-01-01

    Fatal and nonfatal injuries resulting from gun violence remain a persistent problem in the United States. The available research suggests that gun violence diffuses among people and across places through social relationships. Understanding the relationship between gun violence within social networks and individual gun violence risk is critical in preventing the spread of gun violence within populations. This systematic review examines the existing scientific evidence on the transmission of gun and other weapon-related violence in household, intimate partner, peer, and co-offending networks. Our review identified 16 studies published between 1996 and 2015 that suggest that exposure to a victim or perpetrator of violence in one's interpersonal relationships and social networks increases the risk of individual victimization and perpetration. Formal network analyses find high concentrations of gun violence in small networks and that exposure to gun violence in one's networks is highly correlated with one's own probability of being a gunshot victim. Physical violence by parents and weapon use by intimate partners also increase risk for victimization and perpetration. Additional work is needed to better characterize the mechanisms through which network exposures increase individual risk for violence and to evaluate interventions aimed at disrupting the spread of gun and other weapon violence in high-risk social networks. © The Author 2016. Published by Oxford University Press on behalf of the Johns Hopkins Bloomberg School of Public Health. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  16. Gun control saves lives.

    PubMed

    Matzopoulos, Richard

    2016-05-19

    Reducing firearm mortality by means of stricter gun control is one of the most important short- to medium-term measures to address the burden of violence in South Africa, while longer-term interventions and policy measures take effect.

  17. Modification of anisotropic plasma diffusion via auxiliary electrons emitted by a carbon nanotubes-based electron gun in an electron cyclotron resonance ion source.

    PubMed

    Malferrari, L; Odorici, F; Veronese, G P; Rizzoli, R; Mascali, D; Celona, L; Gammino, S; Castro, G; Miracoli, R; Serafino, T

    2012-02-01

    The diffusion mechanism in magnetized plasmas is a largely debated issue. A short circuit model was proposed by Simon, assuming fluxes of lost particles along the axial (electrons) and radial (ions) directions which can be compensated, to preserve the quasi-neutrality, by currents flowing throughout the conducting plasma chamber walls. We hereby propose a new method to modify Simon's currents via electrons injected by a carbon nanotubes-based electron gun. We found this improves the source performances, increasing the output current for several charge states. The method is especially sensitive to the pumping frequency. Output currents for given charge states, at different auxiliary electron currents, will be reported in the paper and the influence of the frequency tuning on the compensation mechanism will be discussed.

  18. Dependence with air density of the response of the PTW SourceCheck ionization chamber for low energy brachytherapy sources.

    PubMed

    Tornero-López, Ana M; Guirado, Damián; Perez-Calatayud, Jose; Ruiz-Arrebola, Samuel; Simancas, Fernando; Gazdic-Santic, Maja; Lallena, Antonio M

    2013-12-01

    Air-communicating well ionization chambers are commonly used to assess air kerma strength of sources used in brachytherapy. The signal produced is supposed to be proportional to the air density within the chamber and, therefore, a density-independent air kerma strength is obtained when the measurement is corrected to standard atmospheric conditions using the usual temperature and pressure correction factor. Nevertheless, when assessing low energy sources, the ionization chambers may not fulfill that condition and a residual density dependence still remains after correction. In this work, the authors examined the behavior of the PTW 34051 SourceCheck ionization chamber when measuring the air kerma strength of (125)I seeds. Four different SourceCheck chambers were analyzed. With each one of them, two series of measurements of the air kerma strength for (125)I selectSeed(TM) brachytherapy sources were performed inside a pressure chamber and varying the pressure in a range from 747 to 1040 hPa (560 to 780 mm Hg). The temperature and relative humidity were kept basically constant. An analogous experiment was performed by taking measurements at different altitudes above sea level. Contrary to other well-known ionization chambers, like the HDR1000 PLUS, in which the temperature-pressure correction factor overcorrects the measurements, in the SourceCheck ionization chamber they are undercorrected. At a typical atmospheric situation of 933 hPa (700 mm Hg) and 20 °C, this undercorrection turns out to be 1.5%. Corrected measurements show a residual linear dependence on the density and, as a consequence, an additional density dependent correction must be applied. The slope of this residual linear density dependence is different for each SourceCheck chamber investigated. The results obtained by taking measurements at different altitudes are compatible with those obtained with the pressure chamber. Variations of the altitude and changes in the weather conditions may produce

  19. Coaxial Plasma Gun Development for the ARPA-E PLX- α Project

    NASA Astrophysics Data System (ADS)

    Witherspoon, F. Douglas; Case, Andrew; Brockington, Samuel

    2015-11-01

    We describe the renewed effort to design and build coaxial plasma guns appropriate for a scaling study of spherically imploding plasma liners as a standoff magneto-inertial-fusion driver under the ARPA-E Accelerating Low-Cost Plasma Heating And Assembly (ALPHA) program. HyperV joins LANL, UAH, UNM, BNL, and Tech-X to develop, build, operate and analyze a 60 plasma gun experiment using the existing PLX facility at LANL. The guns will be designed to operate over a scaling range of operating parameters: 0.5-5.0 mg of Ar, Ne, N2, Kr, and Xe; 20-60 km/s; 1016 -1017 cm-3 muzzle density; and up to 7.5 kJ stored energy per gun. Each gun is planned to incorporate contoured gaps, fast dense gas injection and triggering, and innovative integral sparkgap switching and pfn configurations to reduce inductance, cost, and complexity, and to increase efficiency and system reliability. We will describe the overall design approach for the guns and pulsed power systems. This work supported by the ARPA-E ALPHA Program.

  20. Possible application of electromagnetic guns to impact fusion

    NASA Astrophysics Data System (ADS)

    Kostoff, R. N.; Peaslee, A. T., Jr.; Ribe, F. L.

    1982-01-01

    The possible application of electromagnetic guns to impact fusion for the generation of electric power is discussed, and advantages of impact fusion over the more conventional inertial confinement fusion concepts are examined. It is shown that impact fusion can achieve the necessary high yields, of the order of a few gigajoules, which are difficult to achieve with lasers except at unrealistically high target gains. The rail gun accelerator is well adapted to the delivery of some 10-100 megajoules of energy to the fusion target, and the electrical technology involved is relatively simple: inductive storage or rotating machinery and capacitors. It is concluded that the rail gun has the potential of developing into an impact fusion macroparticle accelerator.

  1. High Velocity Gas Gun

    NASA Technical Reports Server (NTRS)

    1988-01-01

    A video tape related to orbital debris research is presented. The video tape covers the process of loading a High Velocity Gas Gun and firing it into a mounted metal plate. The process is then repeated in slow motion.

  2. Temporal and modal characterization of DoD source air toxic ...

    EPA Pesticide Factsheets

    This project tested three, real-/near real-time monitoring techniques to develop air toxic emission factors for Department of Defense (DoD) platform sources. These techniques included: resonance enhanced multi photon ionization time of flight mass spectrometry (REMPI-TOFMS) for organic air toxics, laser induced breakdown spectroscopy (LIBS) for metallic air toxics, and optical remote sensing (ORS) methods for measurement of criteria pollutants and other hazardous air pollutants (HAPs). Conventional emission measurements were used for verification of the real-time monitoring results. The REMPI-TOFMS system was demonstrated on the following: --a United States U.S. Marine Corps (USMC) diesel generator, --a U.S. Air Force auxiliary power unit (APU), --the waste combustor at the Portsmouth Naval Shipyard, during a multi-monitor environmental technology verification (ETV) test for dioxin monitoring systems, --two dynamometer-driven high mobility multi-purpose wheeled vehicles (HMMWVs), --an idling Abrams battle tank, --a Bradley infantry fighting vehicle (IFV), and --an F-15 and multiple F-22 U.S. Air Force aircraft engines. LIBS was tested and applied solely to the U.S. Marine Corps diesel generator. The high detection limits of LIBS for toxic metals limited its usefulness as a real time analyzer for most DoD sources. ORS was tested only on the APU with satisfactory results for non-condensable combustion products (carbon monoxide [CO], carbon dioxide

  3. Assessment of Near-Source Air Pollution at a Fine Spatial ...

    EPA Pesticide Factsheets

    Mobile monitoring is an emerging strategy to characterize spatially and temporally variable air pollution in areas near sources. EPA’s Geospatial Monitoring of Air Pollution (GMAP) vehicle – an all-electric vehicle measuring real-time concentrations of particulate and gaseous pollutants – was used to map air pollution levels near the Port of Charleston in South Carolina. High-resolution monitoring was performed along driving routes near several port terminals and rail yard facilities, recording geospatial coordinates and concentrations of pollutants including black carbon, size-resolved particle count ranging from ultrafine to coarse (6 nm to 20 um), carbon monoxide, carbon dioxide, and nitrogen dioxide. Additionally, a portable meteorological station was used to characterize local conditions. The primary objective of this work is to characterize the impact of port facilities on local scale air quality. It is found that elevated concentration measurements of Black Carbon and PM correlate to periods of increased port activity and a significant elevation in concentration is observed downwind of ports. However, limitations in study design prevent a more complete analysis of the port effect. As such, we discuss the ways in which this study is limited and how future work could be improved. Mobile monitoring is an emerging strategy to characterize spatially and temporally variable air pollution in areas near sources. EPA’s Geospatial Monitoring of Air Pollut

  4. A new design of indirectly heated cathode based strip type electron gun.

    PubMed

    Maiti, Namita; Lijeesh, K; Barve, U D; Quadri, Nishad; Tembhare, G U; Mukherjee, S; Thakur, K B; Das, A K

    2013-08-01

    A new design of indirectly heated solid cathode based electron gun (200 kW, 45 kV, 270° bent strip type electron gun) has been presented. The design issue addressed is the uniformity of temperature on the solid cathode using (a) a multi-segmented filament with variable height as the primary heat source and (b) trapezoidal shaped single long filament as the primary heat source. The proposed design in this paper is based on computer simulation and validated by extensive experimentations. The design emphasis is on maintaining uniform temperature on the solid cathode. The designed multi-segment filament and the single long filament provide a temperature uniformity on the solid cathode of about 250 K and 110 K, respectively. The better temperature uniformity inspite of the thermal expansion, in case of a single long filament tightly clamped at two ends, has been possible due to shaping of the single filament with a number of constituent sections such that the thermal expansion of different sections forming the actual filament takes care of not only the mechanical stability but also does not affect the emitting surface of the filament. Experiments show that the modified design achieves a one to one correspondence of the solid cathode length and the electron beam length emitted from the solid cathode.

  5. Gun Possession among Massachusetts Batterer Intervention Program Enrollees

    ERIC Educational Resources Information Center

    Rothman, Emily F.; Johnson, Renee M.; Hemenway, David

    2006-01-01

    Batterers with access to firearms present a serious lethal threat to their partners. The purpose of this exploratory study is to estimate the prevalence of and risk markers for gun possession among Massachusetts men enrolled in batterer intervention programs. The authors found that 1.8% of the men reported having a gun in or around their home.…

  6. Air core detectors for Cerenkov-free scintillation dosimetry of brachytherapy β-sources.

    PubMed

    Eichmann, Marion; Thomann, Benedikt

    2017-09-01

    Plastic scintillation detectors are used for dosimetry in small radiation fields with high dose gradients, e.g., provided by β-emitting sources like 106 Ru/ 106 Rh eye plaques. A drawback is a background signal caused by Cerenkov radiation generated by electrons passing the optical fibers (light guides) of this dosimetry system. Common approaches to correct for the Cerenkov signal are influenced by uncertainties resulting from detector positioning and calibration procedures. A different approach to avoid any correction procedure is to suppress the Cerenkov signal by replacing the solid core optical fiber with an air core light guide, previously shown for external beam therapy. In this study, the air core concept is modified and applied to the requirements of dosimetry in brachytherapy, proving its usability for measuring water energy doses in small radiation fields. Three air core detectors with different air core lengths are constructed and their performance in dosimetry for brachytherapy β-sources is compared with a standard two-fiber system, which uses a second fiber for Cerenkov correction. The detector systems are calibrated with a 90 Sr/ 90 Y secondary standard and tested for their angular dependence as well as their performance in depth dose measurements of 106 Ru/ 106 Rh sources. The signal loss relative to the standard detector increases with increasing air core length to a maximum value of 58.3%. At the same time, however, the percentage amount of Cerenkov light in the total signal is reduced from at least 12.1% to a value below 1.1%. There is a linear correlation between induced dose and measured signal current. The air core detectors determine the dose rates for 106 Ru/ 106 Rh sources without any form of correction for the Cerenkov signal. The air core detectors show advantages over the standard two-fiber system especially when measuring in radiation fields with high dose gradients. They can be used as simple one-fiber systems and allow for an almost

  7. The progress of funnelling gun high voltage condition and beam test

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, E.; Ben-Zvi, I.; Gassner, D. M.

    A prototype of a high average current polarized electron funneling gun as an eRHIC injector has been built at BNL. The gun was assembled and tested at Stangenes Incorporated. Two beams were generated from two GaAs photocathodes and combined by a switched combiner field. We observed the combined beams on a YAG crystal and measured the photocurrent by a Faraday cup. The gun has been shipped to Stony Brook University and is being tested there. In this paper we will describe the major components of the gun and recent beam test results. High voltage conditioning is discussed as well.

  8. An Air Quality Data Analysis System for Interrelating Effects, Standards and Needed Source Reductions

    ERIC Educational Resources Information Center

    Larsen, Ralph I.

    1973-01-01

    Makes recommendations for a single air quality data system (using average time) for interrelating air pollution effects, air quality standards, air quality monitoring, diffusion calculations, source-reduction calculations, and emission standards. (JR)

  9. Nerf gun eye injuries: traumatic hyphema.

    PubMed

    Bizrah, Mukhtar; Verma, Seema

    2017-09-18

    Three unrelated patients attended the accident and emergency department with pain and blurred vision after ocular injury with a Nerf gun. Two were adults and one was a child, all of which presented within a 3 months' period. All three cases were found to have ≥1 mm of traumatic hyphema (pooling of blood in anterior chamber of the eye), indicating significant ocular trauma. The two adult patients had formed hyphema and uveitis. The 11-year-old child had formed hyphema, corneal oedema, anterior uveitis, localised angle recession and commotio retinae, which further highlight the severity of the ocular trauma. Significant Nerf gun ocular injuries are not reported in the literature, as far as we know. This case series serves to raise awareness of the seriousness of Nerf gun ocular injuries. It encourages further exploration of reasons for such injuries, as well as a review of protective measures against ocular trauma. © BMJ Publishing Group Ltd (unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  10. Media Agenda Setting Regarding Gun Violence before and after a Mass Shooting.

    PubMed

    Jashinsky, Jared Michael; Magnusson, Brianna; Hanson, Carl; Barnes, Michael

    2016-01-01

    Gun violence is related to substantial morbidity and mortality with surrounding discussions framed and shaped by the media. This study's objective was to explore national news media's reporting of gun violence around a mass shooting. National news pieces were coded according to categories of gun violence, media frames, entities held responsible, responses, and reporting of the public heath approach. Individuals were held responsible for gun violence in 63% of pieces before and 32% after the shooting. Lawmakers were held responsible in 30% of pieces before and 66% after. Background checks were a proposed gun violence prevention method in 18% of pieces before and 55% after Sandy Hook, and lethality reduction of firearms was in 9% before and 57% after. Following a mass shooting, the media tended to hold government, not individuals, primarily responsible. The media often misrepresented the real picture of gun violence and key public health roles.

  11. Gun Dealers, USA.

    ERIC Educational Resources Information Center

    Duker, Laurie; And Others

    In the United States, more than 11,500 adolescents' and young adults' lives are taken each year by firearms. Although Federal law prohibits minors from purchasing handguns, they typically get them by asking someone of legal age (18 years or older) to purchase them from one of the 256,771 Federally licensed gun dealers. This pamphlet answers…

  12. Unusual blunt force wound produced by a gun muzzle.

    PubMed

    Hanzlick, R; Zaki, S A

    1986-09-01

    Most blunt force injuries produced by guns are associated with gun butts, and patterned, muzzle/sight impressions are usually produced by discharging firearms. An unusual and distinct forehead laceration produced by a blow with the muzzle end of a .32 caliber revolver is presented.

  13. Optimization Study of the Ames 0.5 Two-Stage Light Gas Gun

    NASA Technical Reports Server (NTRS)

    Bogdanoff, D. W.

    1996-01-01

    There is a need for more faithful simulation of space debris impacts on various space vehicles. Space debris impact velocities can range up to 14 km/sec and conventional two-stage light gas guns with moderately heavy saboted projectiles are limited to launch velocities of 7-8 km/sec. Any increases obtained in the launch velocities will result in more faithful simulations of debris impacts. It would also be valuable to reduce the maximum gun and projectile base pressures and the gun barrel erosion rate. In this paper, the results of a computational fluid dynamics (CFD) study designed to optimize the performance of the NASA Ames 0.5' gun by systematically varying seven gun operating parameters are reported. Particularly beneficial effects were predicted to occur if (1) the piston mass was decreased together with the powder mass and the hydrogen fill pressure and (2) the pump tube length was decreased. The optimum set of changes in gun operating conditions were predicted to produce an increase in muzzle velocity of 0.7-1.0 km/sec, simultaneously with a substantial decrease in gun erosion. Preliminary experimental data have validated the code predictions. Velocities of up to 8.2 km/sec with a 0.475 cm diameter saboted aluminum sphere have been obtained, along with large reductions in gun erosion rates.

  14. Gas Gun Model and Comparison to Experimental Performance of Pipe Guns Operating with Light Propellant Gases and Large Cryogenic Pellets

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Reed, J. R.; Carmichael, J. R.; Gebhart, T. E.

    Injection of multiple large (~10 to 30 mm diameter) shattered pellets into ITER plasmas is presently part of the scheme planned to mitigate the deleterious effects of disruptions on the vessel components. To help in the design and optimize performance of the pellet injectors for this application, a model referred to as “the gas gun simulator” has been developed and benchmarked against experimental data. The computer code simulator is a Java program that models the gas-dynamics characteristics of a single-stage gas gun. Following a stepwise approach, the code utilizes a variety of input parameters to incrementally simulate and analyze themore » dynamics of the gun as the projectile is launched down the barrel. Using input data, the model can calculate gun performance based on physical characteristics, such as propellant-gas and fast-valve properties, barrel geometry, and pellet mass. Although the model is fundamentally generic, the present version is configured to accommodate cryogenic pellets composed of H2, D2, Ne, Ar, and mixtures of them and light propellant gases (H2, D2, and He). The pellets are solidified in situ in pipe guns that consist of stainless steel tubes and fast-acting valves that provide the propellant gas for pellet acceleration (to speeds ~200 to 700 m/s). The pellet speed is the key parameter in determining the response time of a shattered pellet system to a plasma disruption event. The calculated speeds from the code simulations of experiments were typically in excellent agreement with the measured values. With the gas gun simulator validated for many test shots and over a wide range of physical and operating parameters, it is a valuable tool for optimization of the injector design, including the fast valve design (orifice size and volume) for any operating pressure (~40 bar expected for the ITER application) and barrel length for any pellet size (mass, diameter, and length). Key design parameters and proposed values for the pellet

  15. Gas Gun Model and Comparison to Experimental Performance of Pipe Guns Operating with Light Propellant Gases and Large Cryogenic Pellets

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Combs, S. K.; Reed, J. R.; Lyttle, M. S.

    2016-01-01

    Injection of multiple large (~10 to 30 mm diameter) shattered pellets into ITER plasmas is presently part of the scheme planned to mitigate the deleterious effects of disruptions on the vessel components. To help in the design and optimize performance of the pellet injectors for this application, a model referred to as “the gas gun simulator” has been developed and benchmarked against experimental data. The computer code simulator is a Java program that models the gas-dynamics characteristics of a single-stage gas gun. Following a stepwise approach, the code utilizes a variety of input parameters to incrementally simulate and analyze themore » dynamics of the gun as the projectile is launched down the barrel. Using input data, the model can calculate gun performance based on physical characteristics, such as propellant-gas and fast-valve properties, barrel geometry, and pellet mass. Although the model is fundamentally generic, the present version is configured to accommodate cryogenic pellets composed of H2, D2, Ne, Ar, and mixtures of them and light propellant gases (H2, D2, and He). The pellets are solidified in situ in pipe guns that consist of stainless steel tubes and fast-acting valves that provide the propellant gas for pellet acceleration (to speeds ~200 to 700 m/s). The pellet speed is the key parameter in determining the response time of a shattered pellet system to a plasma disruption event. The calculated speeds from the code simulations of experiments were typically in excellent agreement with the measured values. With the gas gun simulator validated for many test shots and over a wide range of physical and operating parameters, it is a valuable tool for optimization of the injector design, including the fast valve design (orifice size and volume) for any operating pressure (~40 bar expected for the ITER application) and barrel length for any pellet size (mass, diameter, and length). Key design parameters and proposed values for the pellet

  16. Compression-Ignition Sensitivity Studies of Liquid Propellants for Guns

    DTIC Science & Technology

    1979-07-01

    a -- h f m1 Report No. PCRL-F’.-75-004 July 1979 COMPRESSION-I=NITION SDNSITrI"Y STUDIES j? LIQUID PROPELLAhTS rOR GUNS Contract No. DAXK10-78-C-0315...Rmpression- qnition nsitivit 24AU7ud1ies,ś of Liquid Pr ielants or Guns # It) M~oehe BenReuven E6ad Martin ýumme rfielId - AAK10-78-C-0315/J 9...levels and pressurization rates comparable to .’iose of liquid propellant gun (LPG) systems, particularly during the start-up phase o-f the ballistic cycle

  17. Commentary: evidence to guide gun violence prevention in America.

    PubMed

    Webster, Daniel W

    2015-03-18

    Gun violence is a major threat to the public's health and safety in the United States. The articles in this volume's symposium on gun violence reveal the scope of the problem and new trends in mortality rates from gunfire. Leading scholars synthesize research evidence that demonstrates the ability of numerous policies and programs-each consistent with lessons learned from successful efforts to combat public health problems-to prevent gun violence. Each approach presents challenges to successful implementation. Future research should inform efforts to assess which approaches are most effective and how to implement evidence-based interventions most effectively.

  18. The Sources of Air Pollution and Their Control.

    ERIC Educational Resources Information Center

    National Air Pollution Control Administration (DHEW), Arlington, VA.

    The problems of air pollution and its control are discussed. Major consideration is given the sources of pollution - motor vehicles, industry, power plants, space heating, and refuse disposal. Annual emission levels of five principle pollutants - carbon monoxide, sulfur dioxide, nitrogen oxides, hydrocarbons, and particulate matter - are listed…

  19. Improving firearm storage in Alaska native villages: a randomized trial of household gun cabinets.

    PubMed

    Grossman, David C; Stafford, Helen A; Koepsell, Thomas D; Hill, Ryan; Retzer, Kyla D; Jones, Ward

    2012-05-01

    We determined if the installation of gun cabinets improved household firearm storage practices. We used a wait list, randomized trial design with 2 groups. The "early" group received the intervention at baseline, and the "late" group received it at 12 months. Up to 2 gun cabinets were installed in each enrolled home, along with safety messages. In-person surveys were conducted at 12 and 18 months to determine the proportion of households reporting unlocked guns or ammunition. Direct observations of unlocked guns were also compared. At baseline, 93% of homes reported having at least 1 unlocked gun in the home, and 89% reported unlocked ammunition. At 12 months, 35% of homes in the early group reported unlocked guns compared with 89% in the late group (P < .001). Thirty-six percent of the early homes reported unlocked ammunition compared with 84% of late homes (P < .001). The prevalence of these storage practices was maintained at 18 months. Observations of unlocked guns decreased significantly (from 20% to 8%) between groups (P < .03). Gun cabinet installation in rural Alaskan households improved the storage of guns and ammunition. If these gains are sustained over time, it may lead to a reduction in gun-related injuries and deaths in this population.

  20. Secondary emission electron gun using external primaries

    DOEpatents

    Srinivasan-Rao, Triveni [Shoreham, NY; Ben-Zvi, Ilan [Setauket, NY

    2009-10-13

    An electron gun for generating an electron beam is provided, which includes a secondary emitter. The secondary emitter includes a non-contaminating negative-electron-affinity (NEA) material and emitting surface. The gun includes an accelerating region which accelerates the secondaries from the emitting surface. The secondaries are emitted in response to a primary beam generated external to the accelerating region. The accelerating region may include a superconducting radio frequency (RF) cavity, and the gun may be operated in a continuous wave (CW) mode. The secondary emitter includes hydrogenated diamond. A uniform electrically conductive layer is superposed on the emitter to replenish the extracted current, preventing charging of the emitter. An encapsulated secondary emission enhanced cathode device, useful in a superconducting RF cavity, includes a housing for maintaining vacuum, a cathode, e.g., a photocathode, and the non-contaminating NEA secondary emitter with the uniform electrically conductive layer superposed thereon.

  1. Secondary emission electron gun using external primaries

    DOEpatents

    Srinivasan-Rao, Triveni [Shoreham, NY; Ben-Zvi, Ilan [Setauket, NY; Kewisch, Jorg [Wading River, NY; Chang, Xiangyun [Middle Island, NY

    2007-06-05

    An electron gun for generating an electron beam is provided, which includes a secondary emitter. The secondary emitter includes a non-contaminating negative-electron-affinity (NEA) material and emitting surface. The gun includes an accelerating region which accelerates the secondaries from the emitting surface. The secondaries are emitted in response to a primary beam generated external to the accelerating region. The accelerating region may include a superconducting radio frequency (RF) cavity, and the gun may be operated in a continuous wave (CW) mode. The secondary emitter includes hydrogenated diamond. A uniform electrically conductive layer is superposed on the emitter to replenish the extracted current, preventing charging of the emitter. An encapsulated secondary emission enhanced cathode device, useful in a superconducting RF cavity, includes a housing for maintaining vacuum, a cathode, e.g., a photocathode, and the non-contaminating NEA secondary emitter with the uniform electrically conductive layer superposed thereon.

  2. Source attribution and mitigation strategies for air pollution in Delhi

    NASA Astrophysics Data System (ADS)

    Kiesewetter, Gregor; Purohit, Pallav; Schoepp, Wolfgang; Liu, Jun; Amann, Markus; Bhanarkar, Anil

    2017-04-01

    Indian cities, and the megacity of Delhi in particular, have suffered from high air pollution for years. Recent observations show that ambient concentrations of fine particulate matter (PM2.5) in Delhi strongly exceed the Indian national ambient air quality standards as well as the World Health Organization's interim target levels. At the same time, India is experiencing strong urbanization, and both Delhi's emissions as well as the exposed population are growing. Therefore the question arises how PM2.5 concentrations will evolve in the future, and how they can be improved efficiently. In the past, typical responses of the Delhi government to high pollution episodes have been restrictions on motorized road traffic, on power plant operations and on construction activities. However, to design sustainable and efficient pollution mitigation measures, the contribution of different source sectors and spatial scales needs to be quantified. Here we combine the established emission calculation scheme of the Greenhouse Gas - Air Pollution Interactions and Synergies (GAINS) model with regional chemistry-transport model simulations (0.5° resolution) as well as local particle dispersion (2 × 2 km resolution) to arrive at a source attribution of ambient PM2.5 in Delhi. Calculated concentrations compare well to observations. We find that roughly 60% of total population-weighted PM2.5 originates from sources outside the national capital territory of Delhi itself. Consequently, mitigation strategies need to involve neighboring states and address the typical sources there. We discuss the likely evolution of ambient concentrations under different scenarios which assume either current emission control legislation, or application of a Clean Air Scenario foreseeing additional regulations in non-industrial sectors which are often overlooked, such as phase-out of solid fuel cookstoves, and road paving. Only in the case where the Clean Air Scenario is applied both in Delhi as well as in

  3. Preventing Clogging In A Vacuum Plasma Spray Gun

    NASA Technical Reports Server (NTRS)

    Krotz, Phillip D.; Daniel, Ronald L., Jr.; Davis, William M.

    1994-01-01

    Modification of powder-injection ports enables lengthy, high-temperature deposition operations. Graphite inserts prevent clogging of ports through which copper powder injected into vacuum plasma spray (VPS) gun. Graphite liners eliminate need to spend production time refurbishing VPS gun, reducing cost of production and increasing productivity. Concept also applied to other material systems used for net-shape fabrication via VPS.

  4. Everyday Engineering: What Makes a Squirt Gun Squirt?

    ERIC Educational Resources Information Center

    Moyer, Richard; Everett, Susan

    2009-01-01

    You may not think of engineering and squirt guns in the same sentence. However, like many examples of engineering design, the squirt gun pump mechanism is uncomplicated, yet elegant, and very inexpensive to manufacture. The design is widely used because of its simplicity and low cost. With only a few moving parts, it is able to deliver a stream of…

  5. Source apportionment analysis of air pollutants using CMAQ/BFM for national air quality management policy over Republic of Korea.

    NASA Astrophysics Data System (ADS)

    Moon, N.; Kim, S.; Seo, J.; Lee, Y. J.

    2017-12-01

    Recently, the Korean government is focusing on solving air pollution problem such as fine particulate matter and ozone. Korea has high population density and concentrated industrial complex in its limited land space. For better air quality management, it is important to understand source and contribution relation to target pollutant. The air quality analysis representing the mutual contribution among the local regions enables to understand the substantive state of the air quality of a region in association with neighboring regions. Under this background, the source apportionment of PM10, PM2.5, O3, NO2, SO2 using WRF and CMAQ/BFM was analyzed over Korea and BFM was applied to mobile, area and point sources in each local government. The contribution rate from neighboring region showed different pattern for each pollutant. In case of primary pollutants such as NO2, SO2, local source contribution is dominant, on the other hand secondary pollutants case especially O3, contribution from neighboring region is higher than that from source region itself. Local source contribution to PM10 showed 20-25% and the contribution rate to O3 has big difference with different meteorological condition year after year. From this study, we tried to estimate the conversion rate between source (NOx, VOC, SO2, NH3, PMC, PM2.5, CO) and concentration (PM10, PM2.5, O3, NO2, SO2,) by regional group over Korea. The result can contribute to the decision-making process of important national planning related to large-scale industrial developments and energy supply policies (eg., operations of coal-fired power plants and diesel cars) and emission control plan, where many controversies and concerns are currently concentrated among local governments in Korea. With this kind of approach, various environmental and social problems related to air quality can also be identified early so that a sustainable and environmentally sound plan can be established by providing data infrastructures to be utilized

  6. Los Alamos Guns Take Aim at Material's Mysteries

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Byers, Mark; Moore, David; Dimarino, Steve

    Los Alamos National Laboratory scientists and technicians conduct thousands of experiments a year, delving into the fundamental nature of everything from supernovas to subatomic particles. One set of instruments used to better understand the fundamental nature of various materials are 10 scientific gun systems that fire various projectiles at high-tech targets to create enormous velocities, pressures, and temperatures - and using laser, x-ray, and other diagnostics - explore the very nature of metals and other materials. The hundreds of gun-based experiments conducted every year at the Laboratory require a highly-skilled staff of scientists and technicians, and has given rise tomore » a special organization called the "gun working group" to foster open communications, cooperation, problem-solving, and a healthy safety culture.« less

  7. Los Alamos Guns Take Aim at Material's Mysteries

    ScienceCinema

    Byers, Mark; Moore, David; Dimarino, Steve

    2018-05-30

    Los Alamos National Laboratory scientists and technicians conduct thousands of experiments a year, delving into the fundamental nature of everything from supernovas to subatomic particles. One set of instruments used to better understand the fundamental nature of various materials are 10 scientific gun systems that fire various projectiles at high-tech targets to create enormous velocities, pressures, and temperatures - and using laser, x-ray, and other diagnostics - explore the very nature of metals and other materials. The hundreds of gun-based experiments conducted every year at the Laboratory require a highly-skilled staff of scientists and technicians, and has given rise to a special organization called the "gun working group" to foster open communications, cooperation, problem-solving, and a healthy safety culture.

  8. Cyclic Gun--Human Evolution: Soldiers, Guns, Machine Logic, and the Future

    ERIC Educational Resources Information Center

    Blackmore, Tim

    2006-01-01

    Guns, slug-throwing weapons, have evolved as humans have increased their grasp of the mechanical arts. In the near future, however, it seems likely that soldiers' rifles operating at punishing cyclic rates of fire face the limits of physics and materials science--heat and speed will cost accuracy and distance. This article considers not only the…

  9. Media Agenda Setting Regarding Gun Violence before and after a Mass Shooting

    PubMed Central

    Jashinsky, Jared Michael; Magnusson, Brianna; Hanson, Carl; Barnes, Michael

    2017-01-01

    Gun violence is related to substantial morbidity and mortality with surrounding discussions framed and shaped by the media. This study’s objective was to explore national news media’s reporting of gun violence around a mass shooting. National news pieces were coded according to categories of gun violence, media frames, entities held responsible, responses, and reporting of the public heath approach. Individuals were held responsible for gun violence in 63% of pieces before and 32% after the shooting. Lawmakers were held responsible in 30% of pieces before and 66% after. Background checks were a proposed gun violence prevention method in 18% of pieces before and 55% after Sandy Hook, and lethality reduction of firearms was in 9% before and 57% after. Following a mass shooting, the media tended to hold government, not individuals, primarily responsible. The media often misrepresented the real picture of gun violence and key public health roles. PMID:28119907

  10. Guns in Intimate Partner Violence: Comparing Incidents by Type of Weapon.

    PubMed

    Sorenson, Susan B

    2017-03-01

    The goal of this study was to assess the frequency, nature, and outcome of weapon use in intimate partner violence (IPV) and to assess compliance with related gun policies. Data were drawn from forms police are mandated to complete at the scene of IPV in the fifth largest U.S. city during 2013. Proportions were calculated and odds ratios were adjusted for demographic and contextual characteristics and a Bonferroni correction for multiple statistical tests was applied. Of the 35,413 incidents, 6,573 involved hands, fists, or feet, and 1,866 involved external weapons of which 576 were guns. Most incidents were male-on-female: 63.4% (no weapon), 77.4% (bodily weapon), 50.2% (nongun external weapon), and 79.5% (gun). Guns were used most often to threaten the partner (69.1%). When a gun (vs. bodily or nongun external weapon) was used, IPV victims were less likely to have visible injuries (adjusted odds ratio [AOR] = 0.64 and 0.23, respectively)-offenders were less likely to have pushed or shoved, grabbed, punched, or kicked the victim-but (victims) were more likely to be frightened (AOR = 3.13 and 1.49, respectively). Weapon use of any type by an intimate partner is associated with a wide range of violent offender behavior and multiple negative outcomes for victims. The use of a gun has implications that include, but go beyond, physical injury of the victim. Documentation of the enforcement of state law regarding gun removal merits improvement, which has important implications for the evaluation of policies designed to keep guns out of the hands of abusers.

  11. Guns in Intimate Partner Violence: Comparing Incidents by Type of Weapon

    PubMed Central

    2017-01-01

    Abstract Objective: The goal of this study was to assess the frequency, nature, and outcome of weapon use in intimate partner violence (IPV) and to assess compliance with related gun policies. Methods: Data were drawn from forms police are mandated to complete at the scene of IPV in the fifth largest U.S. city during 2013. Proportions were calculated and odds ratios were adjusted for demographic and contextual characteristics and a Bonferroni correction for multiple statistical tests was applied. Results: Of the 35,413 incidents, 6,573 involved hands, fists, or feet, and 1,866 involved external weapons of which 576 were guns. Most incidents were male-on-female: 63.4% (no weapon), 77.4% (bodily weapon), 50.2% (nongun external weapon), and 79.5% (gun). Guns were used most often to threaten the partner (69.1%). When a gun (vs. bodily or nongun external weapon) was used, IPV victims were less likely to have visible injuries (adjusted odds ratio [AOR] = 0.64 and 0.23, respectively)—offenders were less likely to have pushed or shoved, grabbed, punched, or kicked the victim—but (victims) were more likely to be frightened (AOR = 3.13 and 1.49, respectively). Conclusions: Weapon use of any type by an intimate partner is associated with a wide range of violent offender behavior and multiple negative outcomes for victims. The use of a gun has implications that include, but go beyond, physical injury of the victim. Documentation of the enforcement of state law regarding gun removal merits improvement, which has important implications for the evaluation of policies designed to keep guns out of the hands of abusers. PMID:28134571

  12. Micro-gun based on laser pulse propulsion.

    PubMed

    Yu, Haichao; Li, Hanyang; Cui, Lugui; Liu, Shuangqiang; Yang, Jun

    2017-11-24

    This paper proposes a novel "micro-gun" structure for laser pulse propulsion. The "micro-bullets" (glass microspheres) are irradiated by a laser pulse with a 10 ns duration in a dynamic process. Experimental parameters such as the microsphere diameter and the laser pulse energy are varied to investigate their influence on laser pulse propulsion. The energy field and spatial intensity distribution in the capillary tube were simulated using a three-dimensional finite-difference time-domain method. The experimental results demonstrate that the propulsion efficiency is dependent on the laser pulse energy and the microsphere size. The propulsion modes and sources of the propelling force were confirmed through direct observation and theoretical calculation. Waves also generated by light-pressure and thermal expansions assisted the propulsion.

  13. Hartford's gun buy-back program: are we on target?

    PubMed

    Marinelli, Laura W; Thaker, Shefali; Borrup, Kevin; Shapiro, David S; Bentley, George C; Saleheen, Hassan; Lapidus, Garry; Campbell, Brendan T

    2013-09-01

    Gunbuy-backprograms have been proposed as away to remove unwanted firearms from circulation, but remain controversial because their ability to prevent firearm injuries remains unproven. The purpose of this study is to describe the demographics of individuals participating in Connecticut's gun buy-backprogram in the context of annual gun sales and the epidemiology of firearm violence in the state. Over four years the buy-back program collected 464 firearms, including 232 handguns. In contrast, 91,602 firearms were sold in Connecticut during 2009 alone. The incidence of gun-related deaths was unchanged in the two years following the inception of the buy-back program. Suicide was associated with older age (mean = 51 +/- 18years) and Caucasian race (n = 539, 90%). Homicide was associated with younger age (mean = 30 +/- 12 years) and minority race (n = 425, 81%). A gun buy-back program alone is not likely to produce a measurable decrease in firearm injuries and deaths.

  14. Short haul air passenger data sources in the United States

    NASA Technical Reports Server (NTRS)

    Al-Kazily, J.; Gosling, G.; Horonjeff, R.

    1977-01-01

    The sources and characteristics of existing data on short haul air passenger traffic in the United States domestic air market are described along with data availability, processing, and costs. Reference is made to data derived from aircraft operations since these data can be used to insure that no short haul operators are omitted during the process of assembling passenger data.

  15. College Student Attitudes Towards "Smart" Guns: Results from a Nationwide Survey.

    PubMed

    Wallace, Lacey N; Dunn, Kaylin C

    2018-02-01

    Existing studies focusing on "smart" guns, weapons that can only be fired by an authorized user, have focused largely on overall views towards the topic. Little is known about how views differ within key demographics or why Americans feel positively or negatively towards smart guns. This study used data from a nationwide web survey of 520 college students to address these concerns. Multinomial regression was used to identify patterns of smart gun preference in quantitative data. Respondents' open-ended reasoning for their views was examined through common themes and descriptive statistics. About half of the sample preferred smart guns over traditional firearms, with support more likely among females and liberals. Those with more advanced academic standing were more likely to have a traditional gun preference. The sample did not rank cost as a significant concern. Child protection was a much less prominent theme than concerns over (un)authorized users.

  16. Dependence with air density of the response of the PTW SourceCheck ionization chamber for low energy brachytherapy sources

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tornero-López, Ana M.; Guirado, Damián; Ruiz-Arrebola, Samuel

    2013-12-15

    Purpose: Air-communicating well ionization chambers are commonly used to assess air kerma strength of sources used in brachytherapy. The signal produced is supposed to be proportional to the air density within the chamber and, therefore, a density-independent air kerma strength is obtained when the measurement is corrected to standard atmospheric conditions using the usual temperature and pressure correction factor. Nevertheless, when assessing low energy sources, the ionization chambers may not fulfill that condition and a residual density dependence still remains after correction. In this work, the authors examined the behavior of the PTW 34051 SourceCheck ionization chamber when measuring themore » air kerma strength of {sup 125}I seeds.Methods: Four different SourceCheck chambers were analyzed. With each one of them, two series of measurements of the air kerma strength for {sup 125}I selectSeed{sup TM} brachytherapy sources were performed inside a pressure chamber and varying the pressure in a range from 747 to 1040 hPa (560 to 780 mm Hg). The temperature and relative humidity were kept basically constant. An analogous experiment was performed by taking measurements at different altitudes above sea level.Results: Contrary to other well-known ionization chambers, like the HDR1000 PLUS, in which the temperature-pressure correction factor overcorrects the measurements, in the SourceCheck ionization chamber they are undercorrected. At a typical atmospheric situation of 933 hPa (700 mm Hg) and 20 °C, this undercorrection turns out to be 1.5%. Corrected measurements show a residual linear dependence on the density and, as a consequence, an additional density dependent correction must be applied. The slope of this residual linear density dependence is different for each SourceCheck chamber investigated. The results obtained by taking measurements at different altitudes are compatible with those obtained with the pressure chamber.Conclusions: Variations of the

  17. Analysis of mobile source air toxics (MSATs)–Near-Road VOC and carbonyl concentrations

    EPA Science Inventory

    Exposures to mobile source air toxics (MSATs) have been associated with numerous adverse health effects. While thousands of air toxic compounds are emitted from mobile sources, a subset of compounds are considered high priority due to their significant contribution to cancer and...

  18. The Evolution of the Combined Allied Headquarters in the North African Theater of Operations from 1942 to 1943

    DTIC Science & Technology

    2015-05-21

    Benjamin Franklin Cooling, Case Studies in the Development of Close Air Support (Washington, DC: Office of Air Force History, United States Air Force, 1990...Leavenworth, as they were able to interpret my very vague guidance and provide a wealth of source documentation that helped my research immeasurably...for example, the M3 Stuart tanks and their 37mm gun giving way later to the M4 Sherman’s 75mm gun.25 The author acknowledges that these theories

  19. LARGE-SCALE PREDICTIONS OF MOBILE SOURCE CONTRIBUTIONS TO CONCENTRATIONS OF TOXIC AIR POLLUTANTS

    EPA Science Inventory

    This presentation shows concentrations and deposition of toxic air pollutants predicted by a 3-D air quality model, the Community Multi Scale Air Quality (CMAQ) modeling system. Contributions from both on-road and non-road mobile sources are analyzed.

  20. Charge Design Considerations and Their Effect on Pressure Waves in Guns

    DTIC Science & Technology

    1980-12-01

    Interior Ballistic Analysis of Guns", "Interior Ballistics of Guns Ed, M. Summerfield and H. Krier, Progress in Astro - nautics and Aeronautics, Vol. 66...8217 • - -O.8 - Fx " • 0.48 S0.2 U G 00 2 4 64_ . -APi (kpsi) Figure 28. Distribution of Pressure-Wave Amplitudes f r the 175-mm, M107 Gun (M86A2, Zone 3