Science.gov

Sample records for air return duct

  1. Advanced Strategy Guideline: Air Distribution Basics and Duct Design

    SciTech Connect

    Burdick, A.

    2011-12-01

    This report discusses considerations for designing an air distribution system for an energy efficient house that requires less air volume to condition the space. Considering the HVAC system early in the design process will allow adequate space for equipment and ductwork and can result in cost savings. Principles discussed that will maximize occupant comfort include delivery of the proper amount of conditioned air for appropriate temperature mixing and uniformity without drafts, minimization of system noise, the impacts of pressure loss, efficient return air duct design, and supply air outlet placement, as well as duct layout, materials, and sizing.

  2. Influence of evaporation ducts on radar sea return

    NASA Astrophysics Data System (ADS)

    Reilly, J. P.; Dockery, G. D.

    1990-04-01

    Modeling of radar sea return is discussed with consideration of propagation conditions. Both the intensity and propagation direction of energy incident at the sea surface can be significantly affected by the refractive condition of the atmosphere. The paper describes and evaluates a model that incorporates both of these effects for the situation where the propagation conditions are characterized as evaporation ducts. Such ducts are the most persistent marine propagation environment on a worldwide basis for low-altitude propagation. It is shown that commonly encountered evaporation ducts can profoundly affect sea returns.

  3. Technology Solutions Case Study: Sealed Air-Return Plenum Retrofit

    SciTech Connect

    none,

    2012-08-01

    In this project, Pacific Northwest National Laboratory researchers greatly improved indoor air quality and HVAC performance by replacing an old, leaky air handler with a new air handler with an air-sealed return plenum with filter; they also sealed the ducts, and added a fresh air intake.

  4. 14 CFR 29.1103 - Induction systems ducts and air duct systems.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Induction systems ducts and air duct... TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY ROTORCRAFT Powerplant Induction System § 29.1103 Induction systems ducts and air duct systems. (a) Each induction system duct upstream of the...

  5. 14 CFR 29.1103 - Induction systems ducts and air duct systems.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Induction systems ducts and air duct systems. 29.1103 Section 29.1103 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY ROTORCRAFT Powerplant Induction System § 29.1103 Induction systems ducts and air...

  6. 14 CFR 25.1103 - Induction system ducts and air duct systems.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... between the air duct source and the airplane unit served by the air. (e) Each auxiliary power unit... other compartment or area of the airplane in which a hazard would be created resulting from the entry...

  7. 14 CFR 25.1103 - Induction system ducts and air duct systems.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... between the air duct source and the airplane unit served by the air. (e) Each auxiliary power unit... other compartment or area of the airplane in which a hazard would be created resulting from the entry...

  8. ANALYSIS OF MEASUREMENT UNCERTAINTIES IN THE NULLING TEST FOR AIR LEAKAGE FROM RESIDENTIAL DUCTS.

    SciTech Connect

    ANDREWS,J.W.

    2001-04-01

    An analysis of measurement uncertainties in a recently proposed method of measuring air leakage in residential duct systems has been carried out. The uncertainties in supply and return leakage rates are expressed in terms of the value of the envelope leakage flow coefficient and the uncertainties in measured pressures and air flow rates. Results of the analysis are compared with data published by two research groups.

  9. AIR DUCTS STAND NEXT TO (AND OUTSIDE OF) REACTOR CABINET ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    AIR DUCTS STAND NEXT TO (AND OUTSIDE OF) REACTOR CABINET AT THE SOUTHWEST AND NORTHEAST CORNERS OF THE REACTOR'S THERMAL SHIELD. THEY WILL BE ENVELOPED IN BIOLOGICAL CONCRETE SHIELD. IN THE SUB-BASEMENT, THE TWO DUCTS WILL JOIN TOGETHER AND EXIT THE BUILDING TO THE FAN HOUSE. CAMERA FACING NORTH. INL NEGATIVE NO. 1625. Unknown Photographer, 3/6/1951 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID

  10. Low-noise flow valve for air ducts

    NASA Technical Reports Server (NTRS)

    Gallo, E. A.

    1970-01-01

    Valve assembly controls air flow from feeder into main duct, with minimum of turbulence, friction, pressure differential, and noise. Valve consists of damper, deflector, and spring. Streamlining of damper and deflector merges flow smoothly, while spring keeps damper and deflector in contact and eliminates valve chatter and damping vibrations.

  11. Vortex Shedding Inside a Baffled Air Duct

    NASA Technical Reports Server (NTRS)

    Davis, Philip; Kenny, R. Jeremy

    2010-01-01

    Common in the operation of both segmented and un-segmented large solid rocket motors is the occurrence of vortex shedding within the motor chamber. A portion of the energy within a shed vortex is converted to acoustic energy, potentially driving the longitudinal acoustic modes of the motor in a quasi-discrete fashion. This vortex shedding-acoustic mode excitation event occurs for every Reusable Solid Rocket Motor (RSRM) operation, giving rise to subsequent axial thrust oscillations. In order to better understand this vortex shedding/acoustic mode excitation phenomena, unsteady CFD simulations were run for both a test geometry and the full scale RSRM geometry. This paper covers the results from the subscale geometry runs, which were based on work focusing on the RSRM hydrodynamics. Unsteady CFD simulation parameters, including boundary conditions and post-processing returns, are reviewed. The results were further post-processed to identify active acoustic modes and vortex shedding characteristics. Probable locations for acoustic energy generation, and subsequent acoustic mode excitation, are discussed.

  12. Cooling air recycling for gas turbine transition duct end frame and related method

    DOEpatents

    Cromer, Robert Harold; Bechtel, William Theodore; Sutcu, Maz

    2002-01-01

    A method of cooling a transition duct end frame in a gas turbine includes the steps of a) directing cooling air into the end frame from a region external of the transition duct and the impingement cooling sleeve; and b) redirecting the cooling air from the end frame into the annulus between the transition duct and the impingement cooling sleeve.

  13. The influence of air duct geometry on air jet direction in aircraft cabin ventilated by mixing ventilation.

    NASA Astrophysics Data System (ADS)

    Fišer, J.; Jícha, M.

    2013-04-01

    The paper deals with instigation of influence of air duct geometry on air jet direction in aircraft cabin ventilated by mixing ventilation. CFD approach was used for investigation and model geometry was based on small aircraft cabin mock-up geometry. Model was also equipped by nine seats and five manikins that represent passengers. The air jet direction was observed for selected ambient environment parameters and several types of air duct geometry and influence of main air duct geometry on jets direction is discussed. The model was created in StarCCM+ ver. 6.04.014 software and polyhedral mesh was used.

  14. 14 CFR 25.1103 - Induction system ducts and air duct systems.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... the auxiliary power unit must be capable of resisting the maximum heat conditions likely to occur. (f) Each auxiliary power unit induction system duct must be constructed of materials that will not...

  15. 14 CFR 25.1103 - Induction system ducts and air duct systems.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... the auxiliary power unit must be capable of resisting the maximum heat conditions likely to occur. (f) Each auxiliary power unit induction system duct must be constructed of materials that will not...

  16. 14 CFR 29.1103 - Induction systems ducts and air duct systems.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... resisting the maximum heat conditions likely to occur. (f) Each auxiliary power unit induction system duct must be constructed of materials that will not absorb or trap hazardous quantities of flammable...

  17. 14 CFR 29.1103 - Induction systems ducts and air duct systems.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... resisting the maximum heat conditions likely to occur. (f) Each auxiliary power unit induction system duct must be constructed of materials that will not absorb or trap hazardous quantities of flammable...

  18. 14 CFR 25.1103 - Induction system ducts and air duct systems.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... the auxiliary power unit must be capable of resisting the maximum heat conditions likely to occur. (f) Each auxiliary power unit induction system duct must be constructed of materials that will not...

  19. 14 CFR 29.1103 - Induction systems ducts and air duct systems.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... resisting the maximum heat conditions likely to occur. (f) Each auxiliary power unit induction system duct must be constructed of materials that will not absorb or trap hazardous quantities of flammable...

  20. Apparatus for supplying conditioned air at a substantially constant temperature and humidity

    NASA Technical Reports Server (NTRS)

    Obler, H. D. (Inventor)

    1980-01-01

    The apparatus includes a supply duct coupled to a source of supply air for carrying the supply air therethrough. A return duct is coupled to the supply duct for carrying return conditioned air therethrough. A temperature reducing device is coupled to the supply duct for decreasing the temperature of the supply and return conditioned air. A by-pass duct is coupled to the supply duct for selectively directing portions of the supply and return conditioned air around the temperature reducing device. Another by-pass duct is coupled to the return duct for selectively directing portions of the return conditioned air around the supply duct and the temperature reduction device. Controller devices selectively control the flow and amount of mixing of the supply and return conditioned air.

  1. Experimental study on the flame behaviors of premixed methane/air mixture in horizontal rectangular ducts

    NASA Astrophysics Data System (ADS)

    Chen, Dongliang; Sun, Jinhua; Chen, Sining; Liu, Yi; Chu, Guanquan

    2007-01-01

    In order to explore the flame propagation characteristics and tulip flame formation mechanism of premixed methane/air mixture in horizontal rectangular ducts, the techniques of Schlieren and high-speed video camera are used to study the flame behaviors of the premixed gases in a closed duct and opened one respectively, and the propagation characteristics in both cases and the formation mechanism of the tulip flame are analyzed. The results show that, the propagation flame in a closed duct is prior to form a tulip flame structure than that in an opened duct, and the tulip flame structure formation in a closed duct is related to the flame propagation velocity decrease. The sharp decrease of the flame propagation velocity is one of the reasons to the tulip flame formation, and the decrease of the flame propagation velocity is due to the decrease of the burned product flow velocity mainly.

  2. Particle deposition in ventilation ducts

    SciTech Connect

    Sippola, Mark R.

    2002-09-01

    Exposure to airborne particles is detrimental to human health and indoor exposures dominate total exposures for most people. The accidental or intentional release of aerosolized chemical and biological agents within or near a building can lead to exposures of building occupants to hazardous agents and costly building remediation. Particle deposition in heating, ventilation and air-conditioning (HVAC) systems may significantly influence exposures to particles indoors, diminish HVAC performance and lead to secondary pollutant release within buildings. This dissertation advances the understanding of particle behavior in HVAC systems and the fates of indoor particles by means of experiments and modeling. Laboratory experiments were conducted to quantify particle deposition rates in horizontal ventilation ducts using real HVAC materials. Particle deposition experiments were conducted in steel and internally insulated ducts at air speeds typically found in ventilation ducts, 2-9 m/s. Behaviors of monodisperse particles with diameters in the size range 1-16 {micro}m were investigated. Deposition rates were measured in straight ducts with a fully developed turbulent flow profile, straight ducts with a developing turbulent flow profile, in duct bends and at S-connector pieces located at duct junctions. In straight ducts with fully developed turbulence, experiments showed deposition rates to be highest at duct floors, intermediate at duct walls, and lowest at duct ceilings. Deposition rates to a given surface increased with an increase in particle size or air speed. Deposition was much higher in internally insulated ducts than in uninsulated steel ducts. In most cases, deposition in straight ducts with developing turbulence, in duct bends and at S-connectors at duct junctions was higher than in straight ducts with fully developed turbulence. Measured deposition rates were generally higher than predicted by published models. A model incorporating empirical equations based on

  3. FIELD EVALUATION OF IMPROVED METHODS FOR MEASURING THE AIR LEAKAGE OF DUCT SYSTEMS UNDER NORMAL OPERATING CONDITIONS IN 51 HOMES

    SciTech Connect

    Paul W. Francisco; Larry Palmiter; Erin Kruse; Bob Davis

    2003-10-18

    Duct leakage in forced-air distribution systems has been recognized for years as a major source of energy losses in residential buildings. Unfortunately, the distribution of leakage across homes is far from uniform, and measuring duct leakage under normal operating conditions has proven to be difficult. Recently, two new methods for estimating duct leakage at normal operating conditions have been devised. These are called the nulling test and the Delta-Q test. Small exploratory studies have been done to evaluate these tests, but previously no large-scale study on a broad variety of homes has been performed to determine the accuracy of these new methods in the field against an independent benchmark of leakage. This sort of study is important because it is difficult in a laboratory setting to replicate the range of leakage types found in real homes. This report presents the results of a study on 51 homes to evaluate these new methods relative to an independent benchmark and a method that is currently used. An evaluation of the benchmark procedure found that it worked very well for supply-side leakage measurements, but not as well on the return side. The nulling test was found to perform well, as long as wind effects were minimal. Unfortunately, the time and difficulty of setup can be prohibitive, and it is likely that this method will not be practical for general use by contractors except in homes with no return ducts. The Delta-Q test was found to have a bias resulting in overprediction of the leakage, which qualitatively confirms the results of previous laboratory, simulation, and small-scale field studies. On average the bias was only a few percent of the air handler flow, but in about 20% of the homes the bias was large. A primary flaw with the Delta-Q test is the assumption that the pressure between the ducts and the house remain constant during the test, as this assumption does not hold true. Various modifications to the Delta-Q method were evaluated as

  4. Should You Have the Air Ducts in Your Home Cleaned?

    MedlinePlus

    ... heat exchangers) may improve the efficiency of your system, resulting in a longer operating life, as well as some energy and maintenance ... spraying or otherwise introducing these materials into the operating duct system may cause much of the material to be ...

  5. Air-sea interaction and spatial variability of the surface evaporation duct in a coastal environment

    NASA Astrophysics Data System (ADS)

    Brooks, Ian M.

    Aircraft observations are presented of the horizontal variability in the depth of the surface evaporation duct and the relationship with the mesoscale structure of air-sea interaction processes. The 2-dimensional fields of near-surface wind, stress, wind-stress curl, air and sea-surface temperature are measured directly for flow around a headland. The sea surface temperature field indicates cold upwelling driven by the wind-stress curl. Boundary-layer stability responds rapidly to the spatial changes in surface temperature. These changes result in modification of the evaporation duct, which decreases significantly in depth over the cooler upwelling water.

  6. Development of an ultrasonic airflow measurement device for ducted air.

    PubMed

    Raine, Andrew B; Aslam, Nauman; Underwood, Christopher P; Danaher, Sean

    2015-01-01

    In this study, an in-duct ultrasonic airflow measurement device has been designed, developed and tested. The airflow measurement results for a small range of airflow velocities and temperatures show that the accuracy was better than 3.5% root mean square (RMS) when it was tested within a round or square duct compared to the in-line Venturi tube airflow meter used for reference. This proof of concept device has provided evidence that with further development it could be a low-cost alternative to pressure differential devices such as the orifice plate airflow meter for monitoring energy efficiency performance and reliability of ventilation systems. The design uses a number of techniques and design choices to provide solutions to lower the implementation cost of the device compared to traditional airflow meters. The design choices that were found to work well are the single sided transducer arrangement for a "V" shaped reflective path and the use of square wave transmitter pulses ending with the necessary 180° phase changed pulse train to suppress transducer ringing. The device is also designed so that it does not have to rely on high-speed analogue to digital converters (ADC) and intensive digital signal processing, so could be implemented using voltage comparators and low-cost microcontrollers. PMID:25954952

  7. Development of an Ultrasonic Airflow Measurement Device for Ducted Air

    PubMed Central

    Raine, Andrew B.; Aslam, Nauman; Underwood, Christopher P.; Danaher, Sean

    2015-01-01

    In this study, an in-duct ultrasonic airflow measurement device has been designed, developed and tested. The airflow measurement results for a small range of airflow velocities and temperatures show that the accuracy was better than 3.5% root mean square (RMS) when it was tested within a round or square duct compared to the in-line Venturi tube airflow meter used for reference. This proof of concept device has provided evidence that with further development it could be a low-cost alternative to pressure differential devices such as the orifice plate airflow meter for monitoring energy efficiency performance and reliability of ventilation systems. The design uses a number of techniques and design choices to provide solutions to lower the implementation cost of the device compared to traditional airflow meters. The design choices that were found to work well are the single sided transducer arrangement for a “V” shaped reflective path and the use of square wave transmitter pulses ending with the necessary 180° phase changed pulse train to suppress transducer ringing. The device is also designed so that it does not have to rely on high-speed analogue to digital converters (ADC) and intensive digital signal processing, so could be implemented using voltage comparators and low-cost microcontrollers. PMID:25954952

  8. Duct System Flammability and Air Sealing Fire Separation Assemblies in the International Residential Code

    SciTech Connect

    Rudd, A.; Prahl, D.

    2014-12-01

    IBACOS identified two barriers that limit the ability of builders to cost-effectively achieve higher energy efficiency levels in housing. These are (1) the use of duct system materials that inherently achieve airtightness and are appropriately sized for low-load houses and (2) the ability to air seal fire separation assemblies. The issues identified fall into a gray area of the codes.

  9. Duct System Flammability and Air Sealing Fire Separation Assemblies in the International Residential Code

    SciTech Connect

    Rudd, A.; Prahl, D.

    2014-12-01

    IBACOS identified two barriers that limit the ability of builders to cost-effectively achieve higher energy efficiency levels in housing. These are the use of duct system materials that inherently achieve airtightness and are appropriately sized for low-load houses and the ability to air seal fire separation assemblies. The issues identified fall into a gray area of the codes.

  10. Advanced Strategy Guideline. Air Distribution Basics and Duct Design

    SciTech Connect

    Burdick, Arlan

    2011-12-01

    This report discusses considerations for designing an air distribution system for an energy efficient house that requires less air volume to condition the space. Considering the HVAC system early in the design process will allow adequate space for equipment and ductwork and can result in cost savings.

  11. SENSITIVITY OF THE HOUSE PRESSURE TEST FOR DUCT LEAKAGE TO VARIATIONS IN THE DISTRIBUTION OF AIR LEAKAGE IN THE HOUSE ENVELOPE

    SciTech Connect

    ANDREWS,J.W.

    1998-12-01

    The house pressure test for air leakage in ducts calculates the signed difference between the supply and return leakage from the response of the air pressure in the house to operation of the system fan. The currently accepted version of this calculation was based on particular assumptions about how the house envelope leakage is distributed between the walls, ceiling, and floor. This report generalizes the equation to account for an arbitrary distribution of envelope leakage. It concludes that the currently accepted equation is usually accurate to within {+-}5%, but in a small proportion of cases the results may diverge by 50% or more.

  12. Sensitivity of the house pressure test for duct leakage to variations in the distribution of air leakage in the house envelope

    SciTech Connect

    Andrews, J.W.

    1998-12-01

    The house pressure test for air leakage in ducts calculates the signed difference between the supply and return leakage from the response of the air pressure in the house to operation of the system fan. The currently accepted version of this calculation was based on particular assumptions about how the house envelope leakage is distributed between the walls, ceiling, and floor. This report generalizes the equation to account for an arbitrary distribution of envelope leakage. It concludes that the currently accepted equation is usually accurate to within {+-}5%, but in a small proportion of cases the results may diverge by 50% or more.

  13. Modeling particle loss in ventilation ducts

    SciTech Connect

    Sippola, Mark R.; Nazaroff, William W.

    2003-04-01

    Empirical equations were developed and applied to predict losses of 0.01-100 {micro}m airborne particles making a single pass through 120 different ventilation duct runs typical of those found in mid-sized office buildings. For all duct runs, losses were negligible for submicron particles and nearly complete for particles larger than 50 {micro}m. The 50th percentile cut-point diameters were 15 {micro}m in supply runs and 25 {micro}m in return runs. Losses in supply duct runs were higher than in return duct runs, mostly because internal insulation was present in portions of supply duct runs, but absent from return duct runs. Single-pass equations for particle loss in duct runs were combined with models for predicting ventilation system filtration efficiency and particle deposition to indoor surfaces to evaluate the fates of particles of indoor and outdoor origin in an archetypal mechanically ventilated building. Results suggest that duct losses are a minor influence for determining indoor concentrations for most particle sizes. Losses in ducts were of a comparable magnitude to indoor surface losses for most particle sizes. For outdoor air drawn into an unfiltered ventilation system, most particles smaller than 1 {micro}m are exhausted from the building. Large particles deposit within the building, mostly in supply ducts or on indoor surfaces. When filters are present, most particles are either filtered or exhausted. The fates of particles generated indoors follow similar trends as outdoor particles drawn into the building.

  14. Retrofitting Air Conditioning and Duct Systems in Hot, Dry Climates

    SciTech Connect

    Shapiro, Carl; Aldrich, Robb; Arena, Lois

    2012-07-01

    This technical report describes CARB's work with Clark County Community Resources Division in Las Vegas, Nevada, to optimize procedures for upgrading cooling systems on existing homes in the area to implement health, safety, and energy improvements. Detailed monitoring of five AC systems showed that three of the five systems met or exceeded air flow rate goals.

  15. Dual fan, dual-duct system meets air quality, energy-efficiency needs

    SciTech Connect

    Schuler, M.

    1996-03-01

    Canada`s Space Centre in Saint-Hubert Quebec is a 300,000 ft{sup 2} (27,871 m{sup 2}) complex that houses the headquarters of the Canadian Space Agency, the Canadian Astronaut Training Centre, mission ground control installations, research facilities, offices and the required support facilities. A comfortable, pleasant research environment was a primary concern for the Space Centre, given its elite clientele. The objectives were high indoor-air quality, design flexibility, energy efficiency and low capital costs. Dual duct systems which are the heart of the mechanical concept allowed the designers to meet these objectives. The Space Centre`s offices, laboratories and conference center are all served by dual-duct systems. All operate using an air economizer cycle. Gas boilers provide them with hot water for heating and steam for humidification while centrifugal chillers provide chilled water for cooling. This article describes the design.

  16. Numerical simulation of flow in a circular duct fitted with air-jet vortex generators

    NASA Astrophysics Data System (ADS)

    Küpper, Christoph; Henry, Frank S.

    2002-04-01

    Most of the fundamental studies of the use of air-jet vortex generators (AJVGs) have concentrated on their potential ability to inhibit boundary layer separation on aerofoils. However, AJVGs may be of use in controlling or enhancing certain features of internal duct flows. For example, they may be of use in controlling the boundary layer at the entrance to engine air intakes, or as a means of increasing mixing and heat transfer. The objective of this paper is to analyse the flow field in the proximity of an air-jet vortex generator array in a duct by using two local numerical models, i.e. a simple flat plate model and a more geometrically faithful sector model. The sector model mirrors the circular nature of the duct's cross-section and the centre line conditions on the upper boundary. The flow was assumed fully turbulent and was solved using the finite volume, Navier-Stokes Code CFX 4 (CFDS, AEA Technology, Harwell) on a non-orthogonal, body-fitted, grid using the k- turbulence model and standard wall functions. Streamwise, vertical and cross-stream velocity profiles, circulation and peak vorticity decay, peak vorticity paths in cross-stream and streamwise direction, cross-stream vorticity profiles and cross-stream wall shear stress distributions were predicted. Negligible difference in results was observed between the flat plate and the sector model, since the produced vortices were small relative to the duct diameter and close to the surface. The flow field was most enhanced, i.e. maximum thinning of the boundary layer, with a configuration of 30° pitch and 75° skew angle. No significant difference in results could be observed between co- and counter-rotating vortex arrays. Copyright

  17. Whole house particle removal and clean air delivery rates for in-duct and portable ventilation systems.

    PubMed

    Macintosh, David L; Myatt, Theodore A; Ludwig, Jerry F; Baker, Brian J; Suh, Helen H; Spengler, John D

    2008-11-01

    A novel method for determining whole house particle removal and clean air delivery rates attributable to central and portable ventilation/air cleaning systems is described. The method is used to characterize total and air-cleaner-specific particle removal rates during operation of four in-duct air cleaners and two portable air-cleaning devices in a fully instrumented test home. Operation of in-duct and portable air cleaners typically increased particle removal rates over the baseline rates determined in the absence of operating a central fan or an indoor air cleaner. Removal rates of 0.3- to 0.5-microm particles ranged from 1.5 hr(-1) during operation of an in-duct, 5-in. pleated media filter to 7.2 hr(-1) for an in-duct electrostatic air cleaner in comparison to a baseline rate of 0 hr(-1) when the air handler was operating without a filter. Removal rates for total particulate matter less than 2.5 microm in aerodynamic diameter (PM2.5) mass concentrations were 0.5 hr(-1) under baseline conditions, 0.5 hr(-1) during operation of three portable ionic air cleaners, 1 hr(-1) for an in-duct 1-in. media filter, 2.4 hr(-1) for a single high-efficiency particle arrestance (HEPA) portable air cleaner, 4.6 hr(-1) for an in-duct 5-in. media filter, 4.7 hr(-1) during operation of five portable HEPA filters, 6.1 hr(-1) for a conventional in-duct electronic air cleaner, and 7.5 hr(-1) for a high efficiency in-duct electrostatic air cleaner. Corresponding whole house clean air delivery rates for PM2.5 attributable to the air cleaner independent of losses within the central ventilation system ranged from 2 m3/min for the conventional media filter to 32 m3/min for the high efficiency in-duct electrostatic device. Except for the portable ionic air cleaner, the devices considered here increased particle removal indoors over baseline deposition rates. PMID:19044163

  18. High-speed Tests of a Ducted Body with Various Air-outlet Openings

    NASA Technical Reports Server (NTRS)

    Becker, John V.; Baals, Donald D.

    1942-01-01

    Test of a ducted body with Internal flow were made in the 8-foot high-speed wind tunnel for the purpose of studying the effects on external drag and an critical speed of the addition of efficient inlet and outlet openings to a basic streamline shape. Drag tests of a 13.6- inch-diameter streamline body of fineness ratio 6.14 were made at Mach numbers ranging from 0.20 to 0.75. The model was centrally mounted on a 9-percent-thick airfoil and was designed to have an efficient airfoil-body juncture and a high critical speed. An air inlet at the nose and various outlets at the tail were added: drag and internal-flow data were obtained over the given speed range. The critical speed of the ducted bodies was found to be as high as that of the streamline body. The external - drag with air flow through the body did not exceed the drag of the basic streamline shape. No appreciable variation in the efficiency of the diffuser section of the internal duct occurred throughout the Mach number range of the tests.

  19. Evaluation of mixing downstream of tees in duct systems with respect to single point representative air sampling.

    PubMed

    Kim, Taehong; O'Neal, Dennis L; Ortiz, Carlos

    2006-09-01

    Air duct systems in nuclear facilities must be monitored with continuous sampling in case of an accidental release of airborne radionuclides. The purpose of this work is to identify the air sampling locations where the velocity and contaminant concentrations fall below the 20% coefficient of variation required by the American National Standards Institute/Health Physics Society N13.1-1999. Experiments of velocity and tracer gas concentration were conducted on a generic "T" mixing system which included combinations of three sub ducts, one main duct, and air velocities from 0.5 to 2 m s (100 to 400 fpm). The experimental results suggest that turbulent mixing provides the accepted velocity coefficients of variation after 6 hydraulic diameters downstream of the T-junction. About 95% of the cases achieved coefficients of variation below 10% by 6 hydraulic diameters. However, above a velocity ratio (velocity in the sub duct/velocity in the main duct) of 2, velocity profiles were uniform in a shorter distance downstream of the T-junction as the velocity ratio went up. For the tracer gas concentration, the distance needed for the coefficients of variation to drop 20% decreased with increasing velocity ratio due to the sub duct airflow momentum. The results may apply to other duct systems with similar geometries and, ultimately, be a basis for selecting a proper sampling location under the requirements of single point representative sampling. PMID:16891896

  20. Simulation Analysis of Air Flow and Turbulence Statistics in a Rib Grit Roughened Duct

    PubMed Central

    Vogiatzis, I. I.; Denizopoulou, A. C.; Ntinas, G. K.; Fragos, V. P.

    2014-01-01

    The implementation of variable artificial roughness patterns on a surface is an effective technique to enhance the rate of heat transfer to fluid flow in the ducts of solar air heaters. Different geometries of roughness elements investigated have demonstrated the pivotal role that vortices and associated turbulence have on the heat transfer characteristics of solar air heater ducts by increasing the convective heat transfer coefficient. In this paper we investigate the two-dimensional, turbulent, unsteady flow around rectangular ribs of variable aspect ratios by directly solving the transient Navier-Stokes and continuity equations using the finite elements method. Flow characteristics and several aspects of turbulent flow are presented and discussed including velocity components and statistics of turbulence. The results reveal the impact that different rib lengths have on the computed mean quantities and turbulence statistics of the flow. The computed turbulence parameters show a clear tendency to diminish downstream with increasing rib length. Furthermore, the applied numerical method is capable of capturing small-scale flow structures resulting from the direct solution of Navier-Stokes and continuity equations. PMID:25057511

  1. Interpretation of MST radar returns from clear air

    NASA Technical Reports Server (NTRS)

    Liu, C. H.

    1983-01-01

    The nature of the scattering and reflection mechanisms that give rise to the MST radar echoes from the clear air is essential in the correct interpretation of the data about winds, waves, turbulence and stability in the atmosphere. There are two main aspects: the nature of the targets the radar sees and their generation mechanisms; and the signatures of the radar signals returned from the different targets. Volume scatterings from isotropic or anisotropic turbulence, and partial reflections from horizontally stratified, sharp refractive index gradients are believed the main contributors to radar echoes. Combined effects from all the mechanisms probably produce the observed data. The signature of the echo signals for these different scatterers under realistic experimental conditions should be studied. It is hoped from these studies, the nature of the targets can be better understood, and related to atmospheric dynamic processes.

  2. Room-temperature thermal-resistance measurements of new and existing materials for shipboard air-duct systems

    SciTech Connect

    Zarr, R.R.; Somers, T.A.

    1988-10-01

    Thermal resistance measurements of conventional and composite-material insulation for shipboard air duct systems are described. Conventional shipboard air ducts are constructed of metal walls insulated externally with fibrous-glass board. Composite materials are being considered as replacements for these duct walls. Thermal measurements were conducted using the National Bureau of Standards 1-meter Guarded Hot Plate at a mean temperature of 23.9/sup 0/C (75/sup 0/F). Measurements of the fibrous-glass board specimens were within 3% of certified values of NBS SRM 1450a, fibrous-glass board. Measurements of two aramid-fiber honeycomb specimens were approximately one-half the thermal resistance of the fibrous-glass board specimens.

  3. Duct joining system

    DOEpatents

    Proctor, John P.; deKieffer, Robert C.

    2001-01-01

    A duct joining system for providing an air-tight seal and mechanical connection for ducts and fittings is disclosed. The duct joining system includes a flexible gasket affixed to a male end of a duct or fitting. The flexible gasket is affixed at an angle relative to normal of the male end of the duct. The female end of the other duct includes a raised bead in which the flexible gasket is seated when the ducts are properly joined. The angled flexible gasket seated in the raised bead forms an air-tight seal as well as fastens or locks the male end to the female end. Alternatively, when a flexible duct is used, a band clamp with a raised bead is clamped over the female end of the flexible duct and over the male end of a fitting to provide an air tight seal and fastened connection.

  4. Duct Joining System

    DOEpatents

    Proctor, John P.

    2001-02-27

    A duct joining system for providing an air-tight seal and mechanical connection for ducts and fittings is disclosed. The duct joining system includes a flexible gasket affixed to a male end of a duct or fitting. The flexible gasket is affixed at an angle relative to normal of the male end of the duct. The female end of the other duct includes a raised bead in which the flexible gasket is seated when the ducts are properly joined. The angled flexible gasket seated in the raised bead forms an air-tight seal as well as fastens or locks the male end to the female end. Alternatively, when a flexible duct is used, a band clamp with a raised bead is clamped over the female end of the flexible duct and over the male end of a fitting to provide an air tight seal and fastened connection.

  5. High accuracy acoustic relative humidity measurement in duct flow with air.

    PubMed

    van Schaik, Wilhelm; Grooten, Mart; Wernaart, Twan; van der Geld, Cees

    2010-01-01

    An acoustic relative humidity sensor for air-steam mixtures in duct flow is designed and tested. Theory, construction, calibration, considerations on dynamic response and results are presented. The measurement device is capable of measuring line averaged values of gas velocity, temperature and relative humidity (RH) instantaneously, by applying two ultrasonic transducers and an array of four temperature sensors. Measurement ranges are: gas velocity of 0-12 m/s with an error of ± 0.13 m/s, temperature 0-100 °C with an error of ± 0.07 °C and relative humidity 0-100% with accuracy better than 2 % RH above 50 °C. Main advantage over conventional humidity sensors is the high sensitivity at high RH at temperatures exceeding 50 °C, with accuracy increasing with increasing temperature. The sensors are non-intrusive and resist highly humid environments. PMID:22163610

  6. High Accuracy Acoustic Relative Humidity Measurement in Duct Flow with Air

    PubMed Central

    van Schaik, Wilhelm; Grooten, Mart; Wernaart, Twan; van der Geld, Cees

    2010-01-01

    An acoustic relative humidity sensor for air-steam mixtures in duct flow is designed and tested. Theory, construction, calibration, considerations on dynamic response and results are presented. The measurement device is capable of measuring line averaged values of gas velocity, temperature and relative humidity (RH) instantaneously, by applying two ultrasonic transducers and an array of four temperature sensors. Measurement ranges are: gas velocity of 0–12 m/s with an error of ±0.13 m/s, temperature 0–100 °C with an error of ±0.07 °C and relative humidity 0–100% with accuracy better than 2 % RH above 50 °C. Main advantage over conventional humidity sensors is the high sensitivity at high RH at temperatures exceeding 50 °C, with accuracy increasing with increasing temperature. The sensors are non-intrusive and resist highly humid environments. PMID:22163610

  7. STS-56 inflight maintenance (IFM) air duct routing on OV-103's middeck

    NASA Technical Reports Server (NTRS)

    1993-01-01

    STS-56 inflight maintenance (IFM) repair on Discovery's, Orbiter Vehicle (OV) 103's, middeck was required to offset overheating problems with one of the onboard experiments -- Detailed Supplementary Objective (DSO) 322, Human lymphocyte locomotion in microgravity. This 'elephant's trunk' fix was rigged from the airlock's air recirculation duct to DSO 322's forward locker location by Commander Kenneth Cameron. The 'elephant's trunk' was fashioned from trash bags and other plastic items to extend an airline to the troubled area. DSO 322 is collecting data on the locomotion and migration of human lymphocytes through intercellular matrix and is testing the rotating wall vessel and the specimen temperature controller. In the background is the port side wall with the side hatch, middeck accomodations rack (MAR), and shuttle orbiter repackaged galley (SORG) visible.

  8. Sound transmission loss of double plates with an air cavity between them in a rigid duct.

    PubMed

    Kim, Hyun-Sil; Kim, Sang-Ryul; Lee, Seong-Hyun; Seo, Yun-Ho; Ma, Pyung-Sik

    2016-05-01

    In this paper, the sound transmission loss (STL) of thin double plates with an air cavity between them in a rigid duct is considered using an analytical approach. The vibration motion of the plate and sound pressure field are expanded in terms of an infinite series of the modal functions. Under the plane wave condition, a low frequency solution is derived by including the first few symmetric modes. It is determined that the peak frequencies of the double plates coincide with those of each single plate. When the two plates are identical, the STL becomes zero at the natural frequencies of the single plate. However, when the two plates are not identical, the STL is always greater than zero. The location and amplitude of the dips are investigated using an approximate solution when the cavity depth is very small. It is observed that dividing the single plate into two plates with an air cavity in between degrades the STL in the low frequency range, while the equivalent surface mass density is preserved. However, when the cavity depth is not small, the STL of the single plate can be smaller than that of the double plates. PMID:27250128

  9. Economic Returns to Schooling Decisions. AIR Forum 1979 Paper.

    ERIC Educational Resources Information Center

    Belanger, Charles H.; Lavallee, Lise

    The private internal rate of return to investment is evaluated in two levels in each of the following four educational programs: computer science, nursing, nutrition, and social work. In these fields, a situation occurs in which many bachelor's degree graduates and community college vocational degree holders perform exactly the same work and…

  10. Uncertainty Analysis of Air Radiation for Lunar Return Shock Layers

    NASA Technical Reports Server (NTRS)

    Kleb, Bil; Johnston, Christopher O.

    2008-01-01

    By leveraging a new uncertainty markup technique, two risk analysis methods are used to compute the uncertainty of lunar-return shock layer radiation predicted by the High temperature Aerothermodynamic Radiation Algorithm (HARA). The effects of epistemic uncertainty, or uncertainty due to a lack of knowledge, is considered for the following modeling parameters: atomic line oscillator strengths, atomic line Stark broadening widths, atomic photoionization cross sections, negative ion photodetachment cross sections, molecular bands oscillator strengths, and electron impact excitation rates. First, a simplified shock layer problem consisting of two constant-property equilibrium layers is considered. The results of this simplified problem show that the atomic nitrogen oscillator strengths and Stark broadening widths in both the vacuum ultraviolet and infrared spectral regions, along with the negative ion continuum, are the dominant uncertainty contributors. Next, three variable property stagnation-line shock layer cases are analyzed: a typical lunar return case and two Fire II cases. For the near-equilibrium lunar return and Fire 1643-second cases, the resulting uncertainties are very similar to the simplified case. Conversely, the relatively nonequilibrium 1636-second case shows significantly larger influence from electron impact excitation rates of both atoms and molecules. For all cases, the total uncertainty in radiative heat flux to the wall due to epistemic uncertainty in modeling parameters is 30% as opposed to the erroneously-small uncertainty levels (plus or minus 6%) found when treating model parameter uncertainties as aleatory (due to chance) instead of epistemic (due to lack of knowledge).

  11. Space chimp Enos returns to Patrick Air Force Base

    NASA Technical Reports Server (NTRS)

    1961-01-01

    Enos the chimpanzee that orbited the earth twice in a Mercury spacecraft arrives back at Patrick Air Force Base. Enos landed some 220 nautical miles south of Bermuda and was picked up up by the U.S.S. Stormes.

  12. Stabilization of buoyancy-driven unstable vortex flow in mixed convection of air in a rectangular duct by tapering its top plate

    SciTech Connect

    Tseng, W.S.; Lin, W.L.; Yin, C.P.; Lin, C.L.; Lin, T.F.

    2000-02-01

    At high buoyancy-to-inertia ratio frequently encountered in various heat transfer equipment, the buoyancy-driven secondary vortex flow in a forced laminar flow through a bottom heated rectangular duct is rather unstable. Heat transfer augmentation associated with the buoyancy-driven vortex flow is desirable and welcome in many technological applications in which the efficient energy transport is of major concern. Here, stabilization of the buoyancy-driven unstable mixed convective vortex air flow in a bottom heated rectangular duct by tapering its top plate is investigated experimentally. Specifically, the duct is tapered so that its aspect ratio at the duct inlet is 4 and gradually raised to 12 at the exit of the duct. In the study the secondary flow in the duct is visualized and the steady and transient thermal characteristics of the flow are examined by measuring the spanwise distributions of the time-average temperature. The effects of the Reynolds and Grashof numbers on the vortex flow structure are studied in detail. Moreover, the spanwise-averaged Nusselt numbers for the horizontal rectangular and tapering ducts are also measured and compared. Furthermore, the time records of the air temperature are obtained to further detect the temporal stability of the flow. Over the ranges of the Re and Gr investigated for 5 {le} Re {le} 102 and 1.0 x 10{sup 4} {le} Gr {le} 1.7 x 10{sup 5}, the vortex flow induced in the rectangular duct exhibits temporal transition from a steady laminar to time periodic and then to chaotic state at increasing buoyancy-to-inertia ratio. Substantial change in the spatial structure of the vortex flow is also noted to accompany this temporal transition. The results for the tapering duct indicate that more vortex rolls can be induced due to the increase in the aspect ratio of the duct with the axial distance. But the vortex rolls are weaker and are completely stabilized by the tapering of the top plate.

  13. Ignition of lean fuel-air mixtures in a premixing-prevaporizing duct at temperatures up to 1000 K

    NASA Technical Reports Server (NTRS)

    Tacina, R. R.

    1980-01-01

    Conditions were determined in a premixing prevaporizing fuel preparation duct at which ignition occurred. An air blast type fuel injector with nineteen fuel injection points was used to provide a uniform spatial fuel air mixture. The range of inlet conditions where ignition occurred were: inlet air temperatures of 600 to 1000 K air pressures of 180 to 660 kPa, equivalence ratios (fuel air ratio divided by stoichiometric fuel air ratio) from 0.12 to 1.05, and velocities from 3.5 to 30 m/s. The duct was insulated and the diameter was 12 cm. Mixing lengths were varied from 16.5 to 47.6 and residence times ranged from 4.6 to 107 ms. The fuel was no. 2 diesel. Results show a strong effect of equivalence ratio, pressure and temperature on the conditions where ignition occurred. The data did not fit the most commonly used model of auto-ignition. A correlation of the conditions where ignition would occur which apply to this test apparatus over the conditions tested is (p/V) phi to the 1.3 power = 0.62 e to the 2804/T power where p is the pressure in kPa, V is the velocity in m/e, phi is the equivalence ratio, and T is the temperature in K. The data scatter was considerable, varying by a maximum value of 5 at a given temperature and equivalence ratio. There was wide spread in the autoignition data contained in the references.

  14. X-31 Unloading Returning from Paris Air Show

    NASA Technical Reports Server (NTRS)

    1995-01-01

    After being flown in the Paris Air Show in June 1995, the X-31 Enhanced Fighter Maneuverability Technology Demonstrator Aircraft, based at the NASA Dryden Flight Research Center, Edwards Air Force Base, California, is off-loaded from an Air Force Reserve C-5 transport after the ferry flight back to Edwards. At the air show, the X-31 demonstrated the value of using thrust vectoring (directing engine exhaust flow) coupled with advanced flight control systems to provide controlled flight at very high angles of attack. The X-31 Enhanced Fighter Maneuverability (EFM) demonstrator flew at the Ames- Dryden Flight Research Facility, Edwards, California (redesignated the Dryden Flight Research Center in 1994) from February 1992 until 1995 and before that at the Air Force's Plant 42 in Palmdale, California. The goal of the project was to provide design information for the next generation of highly maneuverable fighter aircraft. This program demonstrated the value of using thrust vectoring (directing engine exhaust flow) coupled with an advanced flight control system to provide controlled flight to very high angles of attack. The result was a significant advantage over most conventional fighters in close-in combat situations. The X-31 flight program focused on agile flight within the post-stall regime, producing technical data to give aircraft designers a better understanding of aerodynamics, effectiveness of flight controls and thrust vectoring, and airflow phenomena at high angles of attack. Stall is a condition of an airplane or an airfoil in which lift decreases and drag increases due to the separation of airflow. Thrust vectoring compensates for the loss of control through normal aerodynamic surfaces that occurs during a stall. Post-stall refers to flying beyond the normal stall angle of attack, which in the X-31 was at a 30-degree angle of attack. During Dryden flight testing, the X-31 aircraft established several milestones. On November 6, 1992, the X-31 achieved

  15. Laboratory Evaluation of Air Flow Measurement Methods for Residential HVAC Returns for New Instrument Standards

    SciTech Connect

    Walker, Iain; Stratton, Chris

    2015-08-01

    This project improved the accuracy of air flow measurements used in commissioning California heating and air conditioning systems in Title 24 (Building and Appliance Efficiency Standards), thereby improving system performance and efficiency of California residences. The research team at Lawrence Berkeley National Laboratory addressed the issue that typical tools used by contractors in the field to test air flows may not be accurate enough to measure return flows used in Title 24 applications. The team developed guidance on performance of current diagnostics as well as a draft test method for use in future evaluations. The study team prepared a draft test method through ASTM International to determine the uncertainty of air flow measurements at residential heating ventilation and air conditioning returns and other terminals. This test method, when finalized, can be used by the Energy Commission and other entities to specify required accuracy of measurement devices used to show compliance with standards.

  16. Estimation of the return period for Gumbel processes with applications to air quality measures. Technical report No. 36

    SciTech Connect

    Galfond, G

    1980-03-01

    The return period for a pollutant concentration to exceed a given level is often of interest. For example, the return period for exceeding government standards is a useful measure of long term air quality. Or, for medical reasons, one might be interested in the return period for exceeding some significant harm level. The report examines several estimates of the return period based on extreme value theory and illustrates applications to air quality data.

  17. Laboratory evaluation of welder's exposure and efficiency of air duct ventilation for welding work in a confined space.

    PubMed

    Ojima, J; Shibata, N; Iwasaki, T

    2000-01-01

    CO2 arc welding in a confined space was simulated in a laboratory by manipulating a welding robot which worked in a small chamber to experimentally evaluate the welder's exposure to welding fumes, ozone and carbon monoxide (CO). The effects of the welding arc on the air temperature rise and oxygen (O2) concentration in the chamber were also investigated. The measuring points for these items were located in the presumed breathing zone of a welder in a confined space. The time averaged concentrations of welding fumes, ozone and CO during the arcing time were 83.55 mg/m3, 0.203 ppm and 0.006%, respectively, at a welding current of 120A-200A. These results suggest serious exposure of a welder who operates in a confined space. Air temperature in the chamber rose remarkably due to the arc heat and the increase in the welding current. No clear decrease in the O2 concentration in the chamber was recognized during this welding operation. A model of air duct ventilation was constructed in the small chamber to investigate the strategy of effective ventilation for hazardous welding contaminants in a confined space. With this model we examined ventilation efficiency with a flow rate of 1.08-1.80 m3/min (ventilation rate for 0.40-0.67 air exchanges per minute) in the chamber, and proved that the exposure level was not drastically reduced during arcing time by this air duct ventilation, but the residual contaminants were rapidly exhausted after the welding operation. PMID:10680307

  18. 32 CFR 884.11 - Procedures for return of an Air Force member to the United States.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 32 National Defense 6 2013-07-01 2013-07-01 false Procedures for return of an Air Force member to... OF THE AIR FORCE MILITARY PERSONNEL DELIVERY OF PERSONNEL TO UNITED STATES CIVILIAN AUTHORITIES FOR TRIAL § 884.11 Procedures for return of an Air Force member to the United States. (a) Include...

  19. 32 CFR 884.11 - Procedures for return of an Air Force member to the United States.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 32 National Defense 6 2010-07-01 2010-07-01 false Procedures for return of an Air Force member to... OF THE AIR FORCE MILITARY PERSONNEL DELIVERY OF PERSONNEL TO UNITED STATES CIVILIAN AUTHORITIES FOR TRIAL § 884.11 Procedures for return of an Air Force member to the United States. (a) Include...

  20. 32 CFR 884.11 - Procedures for return of an Air Force member to the United States.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 32 National Defense 6 2014-07-01 2014-07-01 false Procedures for return of an Air Force member to... OF THE AIR FORCE MILITARY PERSONNEL DELIVERY OF PERSONNEL TO UNITED STATES CIVILIAN AUTHORITIES FOR TRIAL § 884.11 Procedures for return of an Air Force member to the United States. (a) Include...

  1. 32 CFR 884.11 - Procedures for return of an Air Force member to the United States.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 32 National Defense 6 2011-07-01 2011-07-01 false Procedures for return of an Air Force member to... OF THE AIR FORCE MILITARY PERSONNEL DELIVERY OF PERSONNEL TO UNITED STATES CIVILIAN AUTHORITIES FOR TRIAL § 884.11 Procedures for return of an Air Force member to the United States. (a) Include...

  2. 32 CFR 884.11 - Procedures for return of an Air Force member to the United States.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 32 National Defense 6 2012-07-01 2012-07-01 false Procedures for return of an Air Force member to... OF THE AIR FORCE MILITARY PERSONNEL DELIVERY OF PERSONNEL TO UNITED STATES CIVILIAN AUTHORITIES FOR TRIAL § 884.11 Procedures for return of an Air Force member to the United States. (a) Include...

  3. Flame behaviors of propane/air premixed flame propagation in a closed rectangular duct with a 90-deg bend

    NASA Astrophysics Data System (ADS)

    He, Xuechao; Sun, Jinhua; Yuen, K. K.; Ding, Yibin; Chen, Sining

    2008-11-01

    Experiments of flame propagation in a small, closed rectangular duct with a 90° bend were performed for a propane-air mixture. The high speed camera and Schlieren techniques were used to record images of flame propagation process in the combustion pipe. Meanwhile, the fine thermocouples and ion current probes were applied to measure the temperature distribution and reaction intensity of combustion. The characteristics of propane-air flame and its microstructure were analyzed in detail by the experimental results. In the test, the special tulip flame formation was observed. Around the bend, the flame tip proceeded more quickly at the lower side with the flame front elongated toward the axial direction. And transition to turbulent flame occurred. It was suggested that fluctuations of velocity, ion current and temperature were mainly due to the comprehensive effects of multi-wave and the intense of turbulent combustion.

  4. Laboratory Evaluation of Air Flow Measurement Methods for Residential HVAC Returns

    SciTech Connect

    Walker, Iain; Stratton, Chris

    2015-07-01

    This project improved the accuracy of air flow measurements used in commissioning California heating and air conditioning systems in Title 24 (Building and Appliance Efficiency Standards), thereby improving system performance and efficiency of California residences. The research team at Lawrence Berkeley National Laboratory addressed the issue that typical tools used by contractors in the field to test air flows may not be accurate enough to measure return flows used in Title 24 applications. The team developed guidance on performance of current diagnostics as well as a draft test method for use in future evaluations. The series of tests performed measured air flow using a range of techniques and devices. The measured air flows were compared to reference air flow measurements using inline air flow meters built into the test apparatus. The experimental results showed that some devices had reasonable results (typical errors of 5 percent or less) but others had much bigger errors (up to 25 percent).

  5. Loft duct project report

    SciTech Connect

    Reed, J.R.

    1993-06-01

    On October 16, 1992, during a routine examination of the loft of Building 332, the Building Coordinator observed cracks in the welds of the duct work that services the fume hoods for Rooms 1313, 1321, and 1329. Further examination revealed cracks in the weld of the duct work that services the gloveboxes in Rooms 1321 and 1329. Upon discovery of the cracked welds, facility management immediately took the following two actions: Because one crack in the fume hood exhaust extended 70% around the duct circumference, a 1-ton chain fall was used to secure the duct to the roof support structure to prevent the duct from falling if the duct completely fractured. The Facility Manager suspended plutonium handling operations in the gloveboxes and work in the fume hoods in the affected rooms until the situation could be thoroughly investigated. Building 332 is ventilated by drawing conditioned air from the building hallways into the laboratories, hoods, and gloveboxes. This air is filtered through two sets of high-efficiency particulate air (HEPA) filters before being exhausted from the facility. Figure 1 is a schematic of the typical air flow pattern for the facility. All affected duct work is located in the loft of the facility or pressure zone 4. This ducting is fabricated from 12-, 14- and 16-gauge, 304 stainless-steel sheet stock and joined by the Gas Tungsten Arc Welding (GTAW) process.

  6. Vortex generator induced heat transfer augmentation past a rib in a heated duct air flow

    SciTech Connect

    Myrum, T.A.; Acharya, S.; Inamdar, S.; Mehrotra, A. )

    1992-02-01

    The present investigation represents the initial phase of a comprehensive experimental program designed to study the potential for increasing the heat transfer per unit pressure drop in a ribbed duct by positioning vortex generators at key locations in the flow. In particular, the present investigation consists of a rib positioned at the inlet to a rectangular test section with uniform heating at its bottom wall. Local and average Nusselt number results are obtained for a circular rod positioned either immediately above or just downstream of the rib.

  7. Experimental Study on Ash-Returned Reactor of CFB Atmospheric Air Gasifier

    NASA Astrophysics Data System (ADS)

    Shihong, Zhang; Luning, Tian; Xianrong, Zhou; Hanping, Chen; Haiping, Yang; Xianhua, Wang

    In an attempt to improve the gasification efficiency and decrease the carbon content in fly ash of atmospheric air CFB gasifiers, an innovatory equipment by name ash-returned reactor is put forward by SKLCC. Ash-returned reactor is an ash-returned apparatus on line of ash circulation, typically like "U" type valve in CFB boilers, with additional function of some extent combustion of residual carbon and increase the furnace inlet temperature of returning ash, and hence the coal conversion of gasifiers is enhanced. As to its configuration compared to conventional "U" type valve, ash-returned rector has two distinguished features of several times of height scale of fluidizing transportation region to meet the combustion reaction time need and appropriate heat transfer tube bundles arranged in the region to moderate the local temperature so as to avoid slagging. And hence, corresponding to the structure renovation, the material transportation and regulation performance of ash-returned reactor is primarily investigated through a series of experiments in a cold lab-scale facility in this paper. The heat transfer characteristic of the tube bundles is then researched and its influential factors are further discussed. These works lay a foundation on the following study of hot state experiments and industrial applications.

  8. LABORATORY EVALUATION OF AIR FLOW MEASUREMENT METHODS FOR RESIDENTIAL HVAC RETURNS

    SciTech Connect

    Walker, Iain; Stratton, Chris

    2015-02-01

    This project improved the accuracy of air flow measurements used in commissioning California heating and air conditioning systems in Title 24 (Building and Appliance Efficiency Standards), thereby improving system performance and efficiency of California residences. The research team at Lawrence Berkeley National Laboratory addressed the issue that typical tools used by contractors in the field to test air flows may not be accurate enough to measure return flows used in Title 24 applications. The team developed guidance on performance of current diagnostics as well as a draft test method for use in future evaluations. The series of tests performed measured air flow using a range of techniques and devices. The measured air flows were compared to reference air flow measurements using inline air flow meters built into the test apparatus. The experimental results showed that some devices had reasonable results (typical errors of 5 percent or less) but others had much bigger errors (up to 25 percent). Because manufacturers’ accuracy estimates for their equipment do not include many of the sources of error found in actual field measurements (and replicated in the laboratory testing in this study) it is essential for a test method that could be used to determine the actual uncertainty in this specific application. The study team prepared a draft test method through ASTM International to determine the uncertainty of air flow measurements at residential heating ventilation and air conditioning returns and other terminals. This test method, when finalized, can be used by the Energy Commission and other entities to specify required accuracy of measurement devices used to show compliance with standards.

  9. Soyuz 22 Return Samples: Assessment of Air Quality Aboard the International Space Station

    NASA Technical Reports Server (NTRS)

    Jams, John T.

    2010-01-01

    Three mini-grab sample containers (m-GSCs) were returned aboard Soyuz 22 because of concerns that new air pollutants were present in the air and these were getting into the water recovery system. The Total Organic Carbon Analyzer had been giving increasing readings of total organic carbon (TOC) in the potable water, and it was postulated that an increased load into the system was responsible. The toxicological assessment of 3 m-GSCs from the ISS is shown in Table 1. The recoveries of the 3 standards (as listed above) from the GSCs averaged 103, 95 and 76%, respectively. Recovery from formaldehyde control badges were 90 and 91%.

  10. Study of Air Ingress Across the Duct During the Accident Conditions

    SciTech Connect

    Hassan, Yassin

    2013-05-06

    The goal of this project is to study the fundamental physical phenomena associated with air ingress in very high temperature reactors (VHTRs). Air ingress may occur due to a rupture of primary piping and a subsequent breach in the primary pressure boundary in helium-cooled and graphite-moderated VHTRs. Significant air ingress is a concern because it introduces potential to expose the fuel, graphite support rods, and core to a risk of severe graphite oxidation. Two of the most probable air ingress scenarios involve rupture of a control rod or fuel access standpipe, and rupture in the main coolant pipe on the lower part of the reactor pressure vessel. Therefore, establishing a fundamental understanding of air ingress phenomena is critical in order to rationally evaluate safety of existing VHTRs and develop new designs that minimize these risks. But despite this importance, progress toward development these predictive capabilities has been slowed by the complex nature of the underlying phenomena. The combination of inter-diffusion among multiple species, molecular diffusion, natural convection, and complex geometries, as well as the multiple chemical reactions involved, impose significant roadblocks to both modeling and experiment design. The project team will employ a coordinated experimental and computational effort that will help gain a deeper understanding of multiphased air ingress phenomena. This project will enhance advanced modeling and simulation methods, enabling calculation of nuclear power plant transients and accident scenarios with a high degree of confidence. The following are the project tasks: Perform particle image velocimetry measurement of multiphase air ingresses; and, Perform computational fluid dynamics analysis of air ingress phenomena.

  11. FRACTIONAL AEROSOL FILTRATION EFFICIENCY OF IN-DUCT VENTILATION AIR CLEANERS

    EPA Science Inventory

    The filtration efficiency of ventilation air cleaners is highly particle-size dependent over the 0.01 to 3 μm diameter size range. Current standardized test methods, which determine only overall efficiencies for ambient aerosol or other test aerosols, provide data of limited util...

  12. 30 CFR 75.507-1 - Electric equipment other than power-connection points; outby the last open crosscut; return air...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... points; outby the last open crosscut; return air; permissibility requirements. 75.507-1 Section 75.507-1... other than power-connection points; outby the last open crosscut; return air; permissibility requirements. (a) All electric equipment, other than power-connection points, used in return air outby the...

  13. 30 CFR 75.507-1 - Electric equipment other than power-connection points; outby the last open crosscut; return air...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... points; outby the last open crosscut; return air; permissibility requirements. 75.507-1 Section 75.507-1... other than power-connection points; outby the last open crosscut; return air; permissibility requirements. (a) All electric equipment, other than power-connection points, used in return air outby the...

  14. Advanced Duct Sealing Testing

    SciTech Connect

    Sherman, Max H.; Walker, Iain S.

    2003-08-01

    Duct leakage has been identified as a major source of energy loss in residential buildings. Most duct leakage occurs at the connections to registers, plenums or branches in the duct system. At each of these connections a method of sealing the duct system is required. Typical sealing methods include tapes or mastics applied around the joints in the system. Field examinations of duct systems have typically shown that these seals tend to fail over extended periods of time. The Lawrence Berkeley National Laboratory has been testing sealant durability for several years. Typical duct tape (i.e. fabric backed tapes with natural rubber adhesives) was found to fail more rapidly than all other duct sealants. This report summarizes the results of duct sealant durability testing of five UL 181B-FX listed duct tapes (three cloth tapes, a foil tape and an Oriented Polypropylene (OPP) tape). One of the cloth tapes was specifically developed in collaboration with a tape manufacturer to perform better in our durability testing. The first test involved the aging of common ''core-to-collar joints'' of flexible duct to sheet metal collars, and sheet metal ''collar-to-plenum joints'' pressurized with 200 F (93 C) air. The second test consisted of baking duct tape specimens in a constant 212 F (100 C) oven following the UL 181B-FX ''Temperature Test'' requirements. Additional tests were also performed on only two tapes using sheet metal collar-to-plenum joints. Since an unsealed flexible duct joint can have a variable leakage depending on the positioning of the flexible duct core, the durability of the flexible duct joints could not be based on the 10% of unsealed leakage criteria. Nevertheless, the leakage of the sealed specimens prior to testing could be considered as a basis for a failure criteria. Visual inspection was also documented throughout the tests. The flexible duct core-to-collar joints were inspected monthly, while the sheet metal collar-to-plenum joints were inspected

  15. Duct leakage impacts on VAV system performance in California large commercial buildings

    SciTech Connect

    Wray, Craig P.; Matson, Nance E.

    2003-10-01

    The purpose of this study is to evaluate the variability of duct leakage impacts on air distribution system performance for typical large commercial buildings in California. Specifically, a hybrid DOE-2/TRNSYS sequential simulation approach was used to model the energy use of a low-pressure terminal-reheat variable-air-volume (VAV) HVAC system with six duct leakage configurations (tight to leaky) in nine prototypical large office buildings (representing three construction eras in three California climates where these types of buildings are common). Combined fan power for the variable-speed-controlled supply and return fans at design conditions was assumed to be 0.8 W/cfm. Based on our analyses of the 54 simulation cases, the increase in annual fan energy is estimated to be 40 to 50% for a system with a total leakage of 19% at design conditions compared to a tight system with 5% leakage. Annual cooling plant energy also increases by about 7 to 10%, but reheat energy decreases (about 3 to 10%). In combination, the increase in total annual HVAC site energy is 2 to 14%. The total HVAC site energy use includes supply and return fan electricity consumption, chiller and cooling tower electricity consumption, boiler electricity consumption, and boiler natural gas consumption. Using year 2000 average commercial sector energy prices for California ($0.0986/kWh and $7.71/Million Btu), the energy increases result in 9 to 18% ($7,400 to $9,500) increases in HVAC system annual operating costs. Normalized by duct surface area, the increases in annual operating costs are 0.14 to 0.18 $/ft{sup 2}. Using a suggested one-time duct sealing cost of $0.20 per square foot of duct surface area, these results indicate that sealing leaky ducts in VAV systems has a simple payback period of about 1.3 years. Even with total leakage rates as low as 10%, duct sealing is still cost effective. This suggests that duct sealing should be considered at least for VAV systems with 10% or more total duct

  16. Lensing duct

    DOEpatents

    Beach, R.J.; Benett, W.J.

    1994-04-26

    A lensing duct to condense (intensify) light using a combination of front surface lensing and reflective waveguiding is described. The duct tapers down from a wide input side to a narrow output side, with the input side being lens-shaped and coated with an antireflective coating for more efficient transmission into the duct. The four side surfaces are uncoated, preventing light from escaping by total internal reflection as it travels along the duct (reflective waveguiding). The duct has various applications for intensifying light, such as in the coupling of diode array pump light to solid state lasing materials, and can be fabricated from inexpensive glass and plastic. 3 figures.

  17. Lensing duct

    DOEpatents

    Beach, Raymond J. , Benett

    1994-01-01

    A lensing duct to condense (intensify) light using a combination of front surface lensing and reflective waveguiding. The duct tapers down from a wide input side to a narrow output side, with the input side being lens-shaped and coated with an antireflective coating for more efficient transmission into the duct. The four side surfaces are uncoated, preventing light from escaping by total internal reflection as it travels along the duct (reflective waveguiding). The duct has various applications for intensifying light, such as in the coupling of diode array pump light to solid state lasing materials, and can be fabricated from inexpensive glass and plastic.

  18. Effects of pulse width and coding on radar returns from clear air

    NASA Technical Reports Server (NTRS)

    Cornish, C. R.

    1983-01-01

    In atmospheric radar studies it is desired to obtain maximum information about the atmosphere and to use efficiently the radar transmitter and processing hardware. Large pulse widths are used to increase the signal to noise ratio since clear air returns are generally weak and maximum height coverage is desired. Yet since good height resolution is equally important, pulse compression techniques such as phase coding are employed to optimize the average power of the transmitter. Considerations in implementing a coding scheme and subsequent effects of an impinging pulse on the atmosphere are investigated.

  19. Soyuz 23 Return Samples: Assessment of Air Quality Aboard the International Space Station

    NASA Technical Reports Server (NTRS)

    James, John T.

    2011-01-01

    Six mini-grab sample containers (m-GSCs) were returned aboard Soyuz 23 because of concerns that new air pollutants had been present in the air and these were getting into the water recovery system. The Total Organic Carbon Analyzer had been giving increasing readings of total organic carbon (TOC) in the potable water, and it was postulated that an increased load into the system was responsible. The TOC began to decline in late October, 2010. The toxicological assessment of 6 m-GSCs from the ISS is shown in Table 1. The recoveries of 13C-acetone, fluorobenzene, and chlorobenzene from the GSCs averaged 73, 82, and 59%, respectively. We are working to understand the sub-optimal recovery of chlorobenzene.

  20. Longevity of duct tape in residential air distribution systems: 1-D, 2-D, and 3-D joints

    SciTech Connect

    Abushakra, Bass

    2002-05-30

    The aging tests conducted so far showed that duct tape tends to degrade in its performance as the joint it is applied to requires a geometrical description of a higher number of space dimensions (1-D, 2-D, 3-D). One-dimensional joints are the easiest to seal with duct tape, and thus the least to experience failure. Two-dimensional joints, such as the flexible duct core-to-collar joints tested in this study, are less likely to fail than three-dimensional collar-to-plenum joints, as the shrinkage could have a positive effect in tightening the joint. Three-dimensional joints are the toughest to seal and the most likely to experience failure. The 2-D flexible duct core-to-collar joints passed the six-month period of the aging test in terms of leakage, but with the exception of the foil-butyl tape, showed degradation in terms hardening, brittleness, partial peeling, shrinkage, wrinkling, delamination of the tape layers, flaking, cracking, bubbling, oozing and discoloration. The baking test results showed that the failure in the duct tape joints could be attributed to the type of combination of the duct tape and the material it is applied to, as the duct tape behaves differently with different substrates. Overall, the foil-butyl tape (Tape 4) had the best results, while the film tape (Tape 3) showed the most deterioration. The conventional duct tapes tested (Tape 1 and Tape 2) were between these two extremes, with Tape 2 performing better than Tape 1. Lastly, we found that plastic straps became discolored and brittle during the tests, and a couple of straps broke completely. Therefore, we recommend that clamping the duct-taped flexible core-to-collar joints should be done with metallic adjustable straps.

  1. Return glider radiosonde for in situ upper-air research measurements

    NASA Astrophysics Data System (ADS)

    Kräuchi, Andreas; Philipona, Rolf

    2016-06-01

    Upper-air balloon soundings for weather predictions have been made since the beginning of the 20th century. New radiosonde instruments for in situ humidity-, radiation- and gas-profile measurements in the troposphere and the lower stratosphere, were introduced in recent years for atmospheric research and climate monitoring, but such instruments are often expensive and it is desired they be reused on multiple flights. Recovering instruments that freely descend with parachutes is time consuming, sometimes difficult and even dangerous. Here, we introduce the return glider radiosonde (RGR), which enables flying and retrieving valuable in situ upper-air instruments. The RGR is lifted with weather balloons similar to traditional radiosondes to a preset altitude, at which time a release mechanism cuts the tether string, and a built-in autopilot flies the glider autonomously back to the launch site or a desired preprogrammed location. Once the RGR reaches the landing coordinates it circles down and releases a parachute 100 m above ground for landing. The motivation for this project was to measure radiation profiles throughout the atmosphere with the same instrument multiple times and with a rapid turn-around time. The paper describes technical aspects of the return glider radiosonde and the built-in radiation instruments and shows test flights up to 24 km altitude that are analyzed in terms of flight performance and maximal distances covered. Several successive flights measuring radiation profiles demonstrate the reliability and the operational readiness of the RGR, allowing new ways for atmospheric in situ research and monitoring with payloads up to several kg depending on the specific size of the glider.

  2. TWO NEW DUCT LEAKAGE TESTS

    SciTech Connect

    ANDREWS,J.W.

    1998-12-01

    Two variations on the tests for duct leakage currently embodied in ASHRAE Standard 152P (Method of Test for Determining the Design and Seasonal Efficiencies of Residential Thermal Distribution Systems) are presented. Procedures are derived for calculating supply and return duct leakage to/from outside using these new variations. Results of these tests are compared with the original ones in Standard 152P on the basis of data collected in three New York State homes.

  3. Two New Duct Leakage Tests

    SciTech Connect

    Andrews, J.W.

    1998-12-01

    Two variations on the tests for duct leakage currently embodied in ASHRAE Standard 152P (Method of Test for Determining the Design and Seasonal Efficiencies of Residential Thermal Distribution Systems) are presented. Procedures are derived for calculating supply and return duct leakage to/from outside using these new variations. Results of these tests are compared with the original ones in Standard 152P on the basis of data collected in three New York State homes.

  4. Effectiveness of duct sealing and duct insulation in multi-family buildings. Final report

    SciTech Connect

    Karins, N.H.; Tuluca, A.; Modera, M.

    1997-07-01

    This research investigated the cost-effectiveness of sealing and insulating the accessible portions of duct systems exposed to unconditioned areas in multifamily housing. Airflow and temperature measurements were performed in 25 apartments served by 10 systems a 9 multi-family properties. The measurements were performed before and after each retrofit, and included apartment airflow (supply and return), duct system temperatures, system fan flow and duct leakage area. The costs for each retrofit were recorded. The data were analyzed and used to develop a prototypical multifamily house. This prototype was used in energy simulations (DOE-2.1E) and air infiltration simulations (COMIS 2.1). The simulations were performed for two climates: New York City and Albany. In each climate, one simulation was performed assuming the basement was tight, and another assuming the basement was leaky. Simulation results and average retrofit costs were used to calculate cost-effectiveness. The results of the analysis indicate that sealing leaks of the accessible ductwork is cost-effective under all conditions simulated (simple payback was between 3 and 4 years). Insulating the accessible ductwork, however, is only cost-effective for buildings with leaky basement, in both climates (simple paybacks were less than 5 years). The simple payback period for insulating the ducts in buildings with tight basements was greater than 10 years, the threshold of cost-effectiveness for this research. 13 refs., 5 figs., 27 tabs.

  5. Range resolution dependence of VHF radar returns from clear-air turbulence and precipitation

    NASA Astrophysics Data System (ADS)

    Chu, Y.-H. Y.-H.; Su, C.-L.

    1999-06-01

    With employing 1.5 h of the data observed by the Chung-Li VHF radar, the range resolution dependences of the VHF backscatter from refractivity fluctuation and precipitation are investigated in this article. It indicates that the atmospheric layer structure of refractivity seems to play a role in governing the range resolution dependence of clear-air turbulent echoes. Observations shows that the VHF clear-air echo power ratios for 4 to 2 μs pulse lengths are close to 3 dB in the middle or bottom side of the layer, while the ratios are significantly greater than 3 dB in the top side of the layer. The analysis of the precipitation echo power ratio for 4 to 2 ms pulse lengths shows that basically the ratios above 3.0 km are close to 3 dB, but enormously smaller than 3 dB below 3.0 km. The feature of extraordinarily small echo power ratios below 3.0 km is also observed for the radar returns from refractivity turbulence. The radar recovery effect is thought to be a primary factor responsible for the severe diminution of the echo power ratios at the lower altitudes. In addition, statistical analysis reveals that the range resolution effect on the first and second moments of the Doppler spectra for the radar echoes from clear-air turbulence and precipitation is insignificant and negligible. The dependences of the coefficient A and power B in the power-law approximation Vt=APBr to the terminal velocity Vt and range-corrected echo power Pr are examined theoretically and experimentally. The results show that the coefficient A (powers B) is inversely (positively) proportional to the range resolution, in a good agreement with the observations. Because of the strong dependence of coefficient A and power B on the radar pulse width, it suggests that great caution should be taken in comparing the power-law expressions Vt=APBr established from the radar returns obtained with different range resolutions.

  6. Autoignition in a premixing-prevaporizing fuel duct using 3 different fuel injection systems at inlet air temperatures to 1250 K

    NASA Technical Reports Server (NTRS)

    Tacina, R. R.

    1983-01-01

    Conditions were determined in a continuous-flow, premixing-prevaporizing duct at which autoignition occurred. Test conditions were representative of an advanced, regenerative-cycle, automotive gas turbine. The test conditions inlet air temperatures from 600 to 1250 K (a vitiated preheater was used), pressures from 170 to 600 kPa, air velocities of 10 to 30 m/sec, equivalence ratios from 0.3 to 1.0, mixing lengths from 10 to 60 cm, and residence times of 2 to 100 ms. The fuel was diesel number 2. The duct was insulated and had an inside diameter of 12 cm. Three different fuel injection systems were used: One was a single simplex pressure atomizer, and the other two were multiple-source injectors. The data obtained with the simplex and one of the multiple-source injectors agreed satisfactorily with the references and correlated with an Arrenhius expression. The data obtained with the other multiple source injector, which used multiple cones to improve the fuel-air distribution, did not correlate well with residence time.

  7. Method and apparatus for duct sealing using a clog-resistant insertable injector

    DOEpatents

    Wang, Duo; Modera, Mark P.

    2010-12-14

    A method for forming a duct access region through one side of a previously installed air duct, wherein the air duct has an air flow with an air flow direction by inserting an aerosol injector into a previously installed air duct through the access region. The aerosol injector includes a liquid tube having a liquid tube orifice for ejecting a liquid to be atomized; and a propellant cap. The method is accomplished by aligning the aerosol injector with the direction of air flow in the duct; activating an air flow within the duct; and spraying a sealant through the aerosol injector to seal the duct in the direction of the air flow.

  8. Duct closure

    DOEpatents

    Vowell, Kennison L.

    1987-01-01

    A closure for an inclined duct having an open upper end and defining downwardly extending passageway. The closure includes a cap for sealing engagement with the open upper end of the duct. Associated with the cap are an array of vertically aligned plug members, each of which has a cross-sectional area substantially conforming to the cross-sectional area of the passageway at least adjacent the upper end of the passageway. The plug members are interconnected in a manner to provide for free movement only in the plane in which the duct is inclined. The uppermost plug member is attached to the cap means and the cap means is in turn connected to a hoist means which is located directly over the open end of the duct.

  9. Cornice Duct System

    SciTech Connect

    Wayne Place; Chuck Ladd

    2004-10-29

    SYNERGETICS, INC., has designed, developed, and tested an air handling duct system that integrates the air duct with the cornice trim of interior spaces. The device has the advantage that the normal thermal losses from ducts into unconditioned attics and crawl spaces can be totally eliminated by bringing the ducts internal to the conditioned space. The following report details work conducted in the second budget period to develop the Cornice Duct System into a viable product for use in a variety of residential or small commercial building settings. A full-scale prototype has been fabricated and tested in a laboratory test building at the Daylighting Facility at North Carolina State University., Based on the results of that testing, the prototype design as been refined, fabricated, installed, and extensively tested in a residential laboratory house. The testing indicates that the device gives substantially superior performance to a standard air distribution system in terms of energy performance and thermal comfort. Patent Number US 6,511,373 B2 has been granted on the version of the device installed and tested in the laboratory house. (A copy of that patent is attached.) Refinements to the device have been carried through two additional design iterations, with a particular focus on reducing installation time and cost and refining the air control system. These new designs have been fabricated and tested and show substantial promise. Based on these design and testing iterations, a final design is proposed as part of this document. That final design is the basis for a continuation in part currently being filed with the U.5, Patent office.

  10. Ramjet bypass duct and preburner configuration

    NASA Technical Reports Server (NTRS)

    Orlando, Robert J. (Inventor)

    1994-01-01

    A combined turbofan and ramjet aircraft engine includes a forward bypass duct which allows the engine to operate more efficiently during the turbofan mode of operation. By mounting a ramjet preburner in the forward duct and isolating this duct from the turbofan bypass air, a transition from turbofan operation to ramjet operation can take place at lower flight Mach numbers without incurring pressure losses or blockage in the turbofan bypass air.

  11. Ensemble Forecasting of Return Flow over the Gulf of Mexico: Value of the Single Upper Air Obseration

    NASA Astrophysics Data System (ADS)

    Lewis, J. M.; Lakshmivarahan, S.; Hu, J.; Weiss, S.

    2014-12-01

    Abstract A case study of return flow over the Gulf of Mexico has been conducted with the intention of determining the value of a single upper-air observation. This case study makes use of a set of upper-air observations collected by the U. S. Coast Guard ship Salvia that followed the trajectory of return-flow air parcels—essentially collecting observations in a Lagrangian frame of reference. A mixed layer model is used to make an ensemble forecast during the outflow phase of the phenomenon—that period when surface-driven buoyancy is the dynamical mechanism that transports moisture and heat into the atmospheric boundary layer. With this low-order nonlinear model, the contributions to forecast uncertainty that stem from initial conditions, boundary conditions, and physical/empirical parameters can be determined separately. These uncertainties serve as input to a three-dimensional variational (3D-Var) data assimilation scheme. Results indicate that the uncertainty in initial conditions dominates the full complement of uncertainties. An experiment is conducted to evaluate the value of a single set of upper-air observations over the Gulf (at a point near the onset of return flow). It is clear from this experiment that observations near the initial onset point significantly improves the forecast of mixing ratio and offers hope for improvement in operational forecasting with a modest increase in resources.

  12. Soyuz 25 Return Samples: Assessment of Air Quality Aboard the International Space Station

    NASA Technical Reports Server (NTRS)

    James, John T.

    2011-01-01

    Six mini-grab sample containers (m-GSCs) were returned aboard Soyuz 25. The toxicological assessment of 6 m-GSCs from the ISS is shown. The recoveries of the 3 internal standards, C-13-acetone, fluorobenzene, and chlorobenzene, from the GSCs averaged 76, 108 and 88%, respectively. Formaldehyde badges were not returned aboard Soyuz 25.

  13. Soyuz 24 Return Samples: Assessment of Air Quality Aboard the International Space Station

    NASA Technical Reports Server (NTRS)

    James, John T.

    2011-01-01

    Fifteen mini-grab sample containers (m-GSCs) were returned aboard Soyuz. This is the first time all samples were acquired with the mini-grab samplers. The toxicological assessment of 15 m-GSCs from the ISS is shown. The recoveries of the 3 internal standards, C(13)-acetone, fluorobenzene, and chlorobenzene, from the GSCs averaged 75, 97 and 79%, respectively. Formaldehyde badges were not returned on Soyuz 24

  14. LABORATORY EVALUATION OF THE DELTA Q TEST FOR DUCT LEAKAGE

    SciTech Connect

    ANDREWS,J.W.

    2003-05-01

    Using a residential-size duct system in a controlled laboratory setting, the repeatability and accuracy of the Delta Q test for air leakage in residential duct systems have been measured. More than 100 Delta Q tests were performed. These were compared with results using fan pressurization and also with results of a procedure (Delta Q Plus) that uses leakage hole-size information to select the leakage pressures to be used in the Delta Q algorithm. The average error in supply or return leakage for the fan-pressurization test was 6.4% of system fan flow. For the Delta Q test it was 3.4% of fan flow, while for Delta Q Plus it was 1.9% of fan flow.

  15. Low-cost orbiting grinder for cutting ducts

    NASA Technical Reports Server (NTRS)

    Lang, E. J.

    1970-01-01

    Low-cost, portable machine cuts ducts made from heat-treated alloys. An abrasive wheel, powered by a high-speed air motor mounted on an expandible plug against the inner wall of the duct, gives precise cutting.

  16. Soyuz 7 Return Samples: Assessment of Air Quality Aboard the International Space Station

    NASA Technical Reports Server (NTRS)

    James, John T.

    2004-01-01

    The toxicological assessments of one grab sample canister (GSC), 6 dual sorbent tubes (DSTs), and 20 formaldehyde badges returned aboard Soyuz 7 are reported. Analytical methods have not changed from earlier reports. Surrogate standard recoveries from the GSC were 84-89%. The recoveries of the less volatile surrogates from the DSTs were 87 to 112%; however, 13C-acetone was only recovered at 53-59%. Formaldehyde recoveries from 2 lab controls were 87 and 95%; trip controls were not returned to ground.

  17. 26 CFR 40.6071(a)-3 - Time for an eligible air carrier to file a return for the third calendar quarter of 2001.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... return for the third calendar quarter of 2001. 40.6071(a)-3 Section 40.6071(a)-3 Internal Revenue... calendar quarter of 2001. (a) In general. If, in the case of an eligible air carrier, the quarterly return required under § 40.6011(a)-1(a) for the third calendar quarter of 2001 includes tax imposed by...

  18. Heat Transfer Enhancement in a Solar Air Heater with Roughened Duct Having Arc-Shaped Elements as Roughness Element on the Absorber Plate

    NASA Astrophysics Data System (ADS)

    Singh, Anil Prakash; Goel, Varun; Vashishtha, Siddhartha; Kumar, Amit

    2016-07-01

    An experimental study has been carried out for the heat transfer and friction characteristics for arc shaped roughness element used in solar air heaters. Duct has an aspect ratio (W/H) of 11, relative roughness pitch (p/e) range of 4-16, relative roughness height (e/D) range of 0.027-0.045, Reynolds number ( Re) range of 2200-22,000 and arc angle (α) was kept constant at 60°. The effects of Re, relative roughness pitch (p/e) and relative roughness height (e/D) on heat transfer and friction factor have been discussed. The results obtained for Nusselt number and friction factor has been compared with smooth solar air heater to see the enhancement in heat transfer and friction factor and it is found out that considerable enhancement takes place in case of heat transfer as well as in friction factor. Correlations were also developed for Nusselt number and friction factor. Thermo-hydraulic performance parameter is also calculated for the same.

  19. Heat Transfer Enhancement in a Solar Air Heater with Roughened Duct Having Arc-Shaped Elements as Roughness Element on the Absorber Plate

    NASA Astrophysics Data System (ADS)

    Singh, Anil Prakash; Goel, Varun; Vashishtha, Siddhartha; Kumar, Amit

    2016-05-01

    An experimental study has been carried out for the heat transfer and friction characteristics for arc shaped roughness element used in solar air heaters. Duct has an aspect ratio (W/H) of 11, relative roughness pitch (p/e) range of 4-16, relative roughness height (e/D) range of 0.027-0.045, Reynolds number (Re) range of 2200-22,000 and arc angle (α) was kept constant at 60°. The effects of Re, relative roughness pitch (p/e) and relative roughness height (e/D) on heat transfer and friction factor have been discussed. The results obtained for Nusselt number and friction factor has been compared with smooth solar air heater to see the enhancement in heat transfer and friction factor and it is found out that considerable enhancement takes place in case of heat transfer as well as in friction factor. Correlations were also developed for Nusselt number and friction factor. Thermo-hydraulic performance parameter is also calculated for the same.

  20. Reducing Uncertainty for the DeltaQ Duct Leakage Test

    SciTech Connect

    Walker, Iain S.; Sherman, Max H.; Dickerhoff, Darryl J.

    2004-05-01

    The thermal distribution system couples the HVAC components to the building envelope, and shares many properties of the buildings envelope including moisture, conduction and most especially air leakage performance. Duct leakage has a strong influence on air flow rates through building envelopes (usually resulting in much greater flows than those due to natural infiltration) because unbalanced duct air flows and leaks result in building pressurization and depressurization. As a tool to estimate this effect, the DeltaQ duct leakage test has been developed over the past several years as an improvement to existing duct pressurization tests. It focuses on measuring the air leakage flows to outside at operating conditions that are required for envelope infiltration impacts and energy loss calculations for duct systems. The DeltaQ test builds on the standard envelope tightness blower door measurement techniques by repeating the tests with the system air handler off and on. The DeltaQ test requires several assumptions to be made about duct leakage and its interaction with the duct system and building envelope in order to convert the blower door results into duct leakage at system operating conditions. This study examined improvements to the DeltaQ test that account for some of these assumptions using a duct system and building envelope in a test laboratory. The laboratory measurements used a purpose-built test chamber coupled to a duct system typical of forced air systems in US homes. Special duct leaks with controlled air-flow were designed and installed into an airtight duct system. This test apparatus allowed the systematic variation of the duct and envelope leakage and accurate measurement of the duct leakage flows for comparison to DeltaQ test results. This paper will discuss the laboratory test apparatus design, construction and operation, the various analysis techniques applied to the calculation procedure and present estimates of uncertainty in measured duct

  1. Laparoscopic common bile duct exploration.

    PubMed

    Vecchio, Rosario; MacFadyen, Bruce V

    2002-04-01

    In recent years, laparoscopic common bile duct exploration has become the procedure of choice in the management of choledocholithiasis in several laparoscopic centers. The increasing interest for this laparoscopic approach is due to the development of instrumentation and technique, allowing the procedure to be performed safely, and it is also the result of the revised role of endoscopic retrograde cholangiopancreatography, which has been questioned because of its cost, risk of complications and effectiveness. Many surgeons, however, are still not familiar with this technique. In this article we discuss the technique and results of laparoscopic common bile duct exploration. Both the laparoscopic transcystic approach and choledochotomy are discussed, together with the results given in the literature. When one considers the costs, morbidity, mortality and the time required before the patient can return to work, it would appear that laparoscopic cholecystectomy with common bile duct exploration is more favorable than open surgery or laparoscopic cholecystectomy with preoperative or postoperative endoscopic sphincterotomy. However, the technique requires advanced laparoscopic skills, including suturing, knot tying, the use of a choledochoscope, guidewire, dilators and balloon stone extractor. Although laparoscopic common bile duct exploration appears to be the most cost-effective method to treat common bile duct stones, it should be emphasized that this procedure is very challenging, and it should be performed by well-trained laparoscopic surgeons with experience in biliary surgery. PMID:11981684

  2. Investigation of the use of fly-ash based autoclaved cellular concrete blocks in coal mines for air duct work. Final report, January 25, 1993--December 31, 1994

    SciTech Connect

    Horvath, M.L.

    1995-06-19

    Coal mines are required to provide ventilation to occupied portions of underground mines. Concrete block is used in this process to construct air duct walls. However, normal concrete block is heavy and not easy to work with and eventually fails dramatically after being loaded due to mine ceiling convergence and/or floor heave. Autoclaved cellular concrete block made from (70{plus_minus}%) coal fly ash is lightweight and less rigid when loaded. It is lighter and easier to use than regular concrete block for underground mine applications. It has also been used in surface construction around the world for over 40 years. Ohio Edison along with eight other electric utility companies, the Electric Power Research Institute (EPRI), and North American Cellular Concrete constructed a mobile demonstration plant to produce autoclaved cellular concrete block from utility fly ash. To apply this research in Ohio, Ohio Edison also worked with the Ohio Coal Development Office and CONSOL Inc. to produce autoclaved cellular concrete block not only from coal ash but also from LIMB ash, SNRB ash, and PFBC ash from various clean coal technology projects sponsored by the Ohio Coal Development Office. The purpose of this project was to demonstrate the potential for beneficial use of fly ash and clean coal technology by-products in the production of lightweight block.

  3. Non-Boltzmann Modeling for Air Shock-Layer Radiation at Lunar-Return Conditions

    NASA Technical Reports Server (NTRS)

    Johnston, Christopher O.; Hollis, Brian R.; Sutton, Kenneth

    2008-01-01

    This paper investigates the non-Boltzmann modeling of the radiating atomic and molecular electronic states present in lunar-return shock-layers. The Master Equation is derived for a general atom or molecule while accounting for a variety of excitation and de-excitation mechanisms. A new set of electronic-impact excitation rates is compiled for N, O, and N2+, which are the main radiating species for most lunar-return shock-layers. Based on these new rates, a novel approach of curve-fitting the non-Boltzmann populations of the radiating atomic and molecular states is developed. This new approach provides a simple and accurate method for calculating the atomic and molecular non-Boltzmann populations while avoiding the matrix inversion procedure required for the detailed solution of the Master Equation. The radiative flux values predicted by the present detailed non-Boltzmann model and the approximate curve-fitting approach are shown to agree within 5% for the Fire 1634 s case.

  4. STS-113/11A: Assessment of Air Quality in the International Space Station (ISS) and Space Shuttle Based on Samples Returned in December 2002 and in May 2003 aboard Soyuz 5

    NASA Technical Reports Server (NTRS)

    James, John T.

    2003-01-01

    The toxicological assessments of grab sample canisters (GSCs) returned aboard STS-l13 and Soyuz 5 are reported. Analytical methods have not changed from earlier reports. Surrogate standard recoveries from the GSCs were 79-120% except as noted in the table. One sample was returned with the valve opened. The two general criteria used to assess air quality are the total-non-methane-volatile organic hydrocarbons (NMVOCs) and the total T-value (minus the CO2 and formaldehyde contributions). Control of atmospheric alcohols is important to the water recovery system engineers, hence total alcohols (including acetone) are also shown for each sample. Octafluoropropane (OFP) has leaked from heat-exchange units in large quantities, so its concentration is tracked separately. Because formaldehyde is quantified from sorbent badges, its concentration is also listed separately. The table shows that the air quality in general was acceptable for crew respiration through the middle of December 2002. No conclusions can be made about the air quality after that date due to NASA's inability to return air samples from the ISS . Alcohols are not being controlled to the recently lowered guideline of 5 mg/m3, which was recommended to protect the water recovery systems. The airlock sample was taken during the regeneration of Met ox canisters in the adjacent Node. The trace pollutants were not increased above background; however, inspection of table 1 in the appendix shows a CO2 concentration of 17,000 mg/cu m, which is a relatively high concentration, but still below the 24-hour SMAC of23,000 mg/cu m. The control of OFP continues to be adequate at least through December 2002. Formaldehyde concentrations suggest that the high levels that were being found in the Lab atmosphere have subsided. This is probably attributable to the restoration of IMV in early February 2003 . Before the obstructing material was removed from ducts the Lab formaldehyde concentrations approached 0.06 mg/cu m, whereas

  5. Field comparison of design and diagnostic pathways for duct efficiency evaluation

    SciTech Connect

    Andrews, J.W.

    1996-08-01

    A new method of test for residential thermal distribution efficiency is currently being developed under the auspices of the American Society of Heating, Refrigerating, and Air-Conditioning Engineers (ASHRAE). This test method will have three main approaches, or ``pathways``, designated Design, Diagnostic, and Research. The Design Pathway uses builder`s information to predict thermal distribution efficiency in new construction. The Diagnostic Pathway uses air-flow, temperature, and pressure-difference tests--intended to take one to four hours--to evaluate thermal distribution efficiency in a completed house. For forced-air systems, three distinct techniques are being considered, one based on thermal inputs and outputs in the duct system, the second based on pressure and leakage-area measurements, and the third based on pressure differentials induced in the house by partial blockage of the return duct. This paper presents and discusses the results of Design Pathway calculations based on measured duct-system and floor-plan layouts and surface areas (in lieu of building plans) for fifteen residential duct systems in Long Island, New York. These are compared with measured Diagnostic Pathway efficiencies in eight of these homes.

  6. BTS Fact Sheet: Improving the efficiency of your duct system

    SciTech Connect

    BNL

    1999-12-28

    The duct system, used in air heating and air cooling your home, is a collection of tubes that distributes the heated or cooled air to the various rooms. The duct system can have an important effect on health of the occupants through the distribution of indoor air pollution. Changes and repairs to a duct system should always be performed by a qualified professional. This brochure is meant to help you understand the problems that can affect the duct system and how you can save money, improve comfort, and protect against potential health hazards.

  7. INTERIOR DUCT SYSTEM DESIGN, CONSTRUCTION, AND PERFORMANCE

    SciTech Connect

    Janet E.R. Mcllvaine; David Beal; Philip Fairey

    2001-10-10

    By removing air distribution and conditioning equipment from unconditioned spaces, homeowners stand to benefit substantially with respect to both energy savings and indoor air quality. Duct leakage introduces: Greater heating and cooling loads from air at extreme temperatures and humidity levels; Outside air and air from unconditioned spaces that may contain air borne contaminants, combustion gases, pollen, mold spores, and/or particles of building materials; and Higher whole-house infiltration/exfiltration rates. Exemplary studies conducted since 1990 have demonstrated the prevalence of duct leakage throughout the United States and measured energy savings of approximately 20% during both heating and cooling seasons from leakage reduction. These all dealt with duct leakage to and/or from unconditioned spaces. In the building science community, leakage within the conditioned space is generally presumed to eliminate the negative consequences of duct leakage with the exception of possibly creating pressure imbalances in the house which relates to higher infiltration and/or exfiltration. The practical challenges of isolating ducts and air handlers from unconditioned spaces require builders to construct an air-tight environment for the ducts. Florida Solar Energy Center researchers worked with four builders in Texas, North Carolina, and Florida who build a furred-down chase located either in a central hallway or at the edges of rooms as an architectural detail. Some comparison homes with duct systems in attics and crawl spaces were included in the test group of more than 20 homes. Test data reveals that all of the duct/AHU systems built inside the conditioned space had lower duct leakage to unconditioned spaces than their conventional counterparts; however, none of the homes was completely free of duct leakage to unconditioned spaces. Common problems included wiring and plumbing penetrations of the chase, failure to treat the chase as an air tight space, and misguided

  8. Flue gas duct assembly

    SciTech Connect

    Montana, F.J.

    1984-08-28

    A length of longitudinally extending duct assembly for heated corrosive gases includes an outer support duct and a substantially gas-tight liner. The liner is spaced from the outer support duct by a relatively yielding spacer material that accommodates expansion of the liner in directions parallel to the inner surface of the outer support duct and in directions normal to the inner surface of the outer support duct without imposing any substantial resistance to such thermal expansion.

  9. Some recent developments in the interpretation of MST radar returns from clear air (keynote paper), part 2

    NASA Technical Reports Server (NTRS)

    Liu, C. H.

    1984-01-01

    Mesosphere-stratosphere-troposphere (MST) radar returns from clear air come about through the interaction of electromagnetic waves with the inhomogeneous structures of refractive index in the atmosphere. In order to interpret the data correctly to obtain information concerning the dynamics of the atmosphere, one must first know how the various refractive index structures can affect the propagation and scattering of the radio waves. This can be achieved through theoretical and model studies. On the other hand, in order to carry out realistic theoretical studies, realistic models of the inhomogeneous structures of the atmospheric refractive index are needed. These are available only through observational data. Therefore the close interplays between theoretical and observational investigations are essential in making progress in this area. Some results on certain aspects of the problem are presented with emphasis on those aspects that may lead to new developments.

  10. Strategy Guideline. Compact Air Distribution Systems

    SciTech Connect

    Burdick, Arlan

    2013-06-01

    This guideline discusses the benefits and challenges of using a compact air distribution system to handle the reduced loads and reduced air volume needed to condition the space within an energy efficient home. The decision criteria for a compact air distribution system must be determined early in the whole-house design process, considering both supply and return air design. However, careful installation of a compact air distribution system can result in lower material costs from smaller equipment, shorter duct runs, and fewer outlets; increased installation efficiencies, including ease of fitting the system into conditioned space; lower loads on a better balanced HVAC system, and overall improved energy efficiency of the home.

  11. Apollo ASTP crewmen return to Ellington Air Force Base, Houston, Texas

    NASA Technical Reports Server (NTRS)

    1975-01-01

    Dr. Christopher C. Kraft Jr. (second from left), JSC Director, chats with the three ASTP crewmen on the runway at Ellington Air Force Base after their arrival home from the Pacific recovery area. The six men are, left to right, Col. Donald Robinson, EAFB commander; Dr. Kraft; Astronaut John W. Young, Chief of the Astronaut office at JSC; Astronaut Vance D. Brand, command module pilot of the crew; Astronaut Donald K. Slayton, docking module pilot of the crew; and Astronaut Thomas P. Stafford, crew commander. This picture was taken prior to the Official welcoming ceremonies (30109); Dr. Glynn S. Lunney (at microphone), American Technical Director of the Apollo Soyuz Test Project, praises the three ASTP crewmen during welcoming home ceremonies at Ellington. The seven persons behind Lunney are, left to right, Dr. Kraft; Mrs Vance D. Brand; Astronaut Brand; Mrs. Donald K. Slayton; Astronaut Slayton; Astronaut Stafford; and Mrs. Thomas P. Stafford. Medical treatment in Hawaii delayed the ret

  12. STS 134, 135 and 26S Return Samples: Air Quality aboard Shuttle (STS-134) and International Space Station

    NASA Technical Reports Server (NTRS)

    James, John T.

    2011-01-01

    This is a very limited set of samples on which to perform an air quality assessment. However, based on these samples, we have no reason to believe that nominal ISS air is unsafe to breathe. We must continue to be vigilant when dealing with nominal atmospheres in ISS. New, unmanned modules require special attention when the crew first enters. Carbon Monoxide Accumulation aboard ISS: Beginning in late 2008 the nominal concentrations of CO began increasing gradually (Figure 1). The results from samples returned on this flight indicate that the CO concentrations, after dropping in late 2009, have cycled upward and then settled back to concentrations near 2 mg/m3. In any case, these changes are well below the 180-day SMAC for CO, which is17 mg/m3. There is no threat to crew health. Carbon Dioxide: This anthropogenic compound has drawn much attention recently because of the possibility that it could contribute to the effects of intracranial hypertension experienced because of spaceflight-induced fluid shifts. From now on we will maintain a plot (Figure 2) of carbon dioxide concentrations ( SD) by averaging the values found in the 3-5 mini-GSC samples taken each month in diverse locations of the ISS. This will enable us to estimate the average exposure of crewmembers to carbon dioxide during their stay aboard the ISS. In general, concentrations are being maintained below 3.5 mmHg. Figure 1

  13. Particle deposition in ventilation ducts: Connectors, bends anddeveloping flow

    SciTech Connect

    Sippola, Mark R.; Nazaroff, William W.

    2004-03-01

    In ventilation duct flow the turbulent flow profile is commonly disturbed or not fully developed and these conditions are likely to influence particle deposition to duct surfaces. Particle deposition rates at eight S-connectors, in two 90{sup o} duct bends and in two ducts where the turbulent flow profile was not fully developed were measured in a laboratory duct system with both galvanized steel and internally insulated ducts with hydraulic diameters of 15.2 cm. In the steel duct system, experiments with nominal particle diameters of 1, 3, 5, 9 and 16 {micro}m were conducted at each of three nominal air speeds: 2.2, 5.3 and 9.0 m/s. In the insulated duct system, deposition of particles with nominal diameters of 1, 3, 5, 8 and 13 {micro}m was measured at nominal air speeds of 2.2, 5.3 and 8.8 m/s. Fluorescent techniques were used to directly measure the deposition velocities of monodisperse fluorescent particles to duct surfaces. Deposition at S-connectors, in bends and in straight ducts with developing turbulence was often greater than deposition in straight ducts with fully developed turbulence for equal particle sizes, air speeds and duct surface orientations. Deposition rates at all locations were found to increase with an increase in particle size or air speed. High deposition rates at S-connectors resulted from impaction and these rates were nearly independent of the orientation of the S-connector. Deposition rates in the two 90{sup o} bends differed by more than an order of magnitude in some cases, probably because of the difference in turbulence conditions at the bend inlets. In straight steel ducts where the turbulent flow profile was developing, the deposition enhancement relative to fully developed turbulence generally increased with air speed and decreased with downstream distance from the duct inlet. This enhancement was greater at the duct ceiling and wall than at the duct floor. In insulated ducts, deposition enhancement was less pronounced overall

  14. On Modeling Air/Space-Borne Radar Returns in the Melting Layer

    NASA Technical Reports Server (NTRS)

    Liao, Liang; Meneghini, Robert

    2005-01-01

    The bright band is the enhanced radar echo associated with the melting of hydrometeors in stratiform rain where the melting process usually occurs below 0 C isotherm over a distance of about 500m. To simulate this radar signature, a scattering model of melting snow is proposed in which the fractional water content is prescribed as a function of the radius of a spherical mixed- phase particle consisting of air, ice and water. The model is based on the observation that melting starts at the surface of the particle and then gradually develops towards the center. To compute the scattering parameters of a non-uniform melting particle, the particle is modeled as a sphere represented by a collection of 64(exp 3) cubic cells of identical size where the probability of water at any cell is prescribed as a function of the radius. The internal field of the particle, used for deriving the effective dielectric constant, is computed by the Conjugate Gradient and Fast Fourier Transform (CGFFT) numerical methods. To make computations of the scattering parameters more efficient, a multi-layer stratified-sphere scattering model is introduced after demonstrating that the scattering parameters of the non-uniformly melting particle can be accurately reproduced by the stratified sphere. In conjunction with a melting layer model that describes the melting fractions and fall velocities of hydrometeors as a function of the distance from the 0 C isotherm, the stratified-sphere model is used to simulate the radar bright band profiles. These simulated profiles are shown to compare well with measurements from the Precipitation Radar (PR) aboard the Tropical Rainfall Measuring Mission (TRMM) satellite and a dual-wavelength airborne radar. The results suggest that the proposed model of a melting snow particle may be useful in studying the characteristics of the bright-band in particular and mixed- phase hydrometeors in general.

  15. 91. VIEW OF OBSOLETE AIRCONDITIONING DUCTS LOCATED IN NORTHWEST CORNER ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    91. VIEW OF OBSOLETE AIR-CONDITIONING DUCTS LOCATED IN NORTHWEST CORNER OF ROOM, ABOVE SLC-3E AUTOPILOT EQUIPMENT. DIGITAL COUNTDOWN AND HOLD CLOCKS ON WALL LEFT OF DUCTS - Vandenberg Air Force Base, Space Launch Complex 3, Launch Operations Building, Napa & Alden Roads, Lompoc, Santa Barbara County, CA

  16. 54. DETAIL OF AIRCONDITIONING EXHAUST DUCTS ON NORTH FACE OF ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    54. DETAIL OF AIR-CONDITIONING EXHAUST DUCTS ON NORTH FACE OF ERECT UMBILICAL MAST - Vandenberg Air Force Base, Space Launch Complex 3, Launch Pad 3 West, Napa & Alden Roads, Lompoc, Santa Barbara County, CA

  17. Propagation Of Sound In Curved Ducts

    NASA Technical Reports Server (NTRS)

    Rostafinski, Wojciech

    1992-01-01

    Monograph presents concise, comprehensive summary of knowledge of propagation of acoustic waves in ducts and pipes including bends. Pulls together information from Lord Rayleigh's book Theory Of Sound, published in 1878, and from 33 papers scattered throughout various scientific journals published between 1945 and 1989. Monograph useful to scientists and engineers interested in such diverse topics as musical instruments, air-conditioning ducts, and jet engines. Material not available in current texts.

  18. Assessment of Air Quality in the Shuttle and International Space Station (ISS) Based on Samples Returned by STS-104 at the Conclusion of 7A

    NASA Technical Reports Server (NTRS)

    James, John T.

    2001-01-01

    The toxicological assessment of air samples returned at the end of the STS-l04 (7 A) flight to the ISS is reported. ISS air samples were taken in June and July 2001 from the Service Module, FGB, and U.S. Laboratory using grab sample canisters (GSCs) and/or formaldehyde badges. Preflight and end-of-mission samples were obtained from Atlantis using GSCs. Solid sorbent air sampler (SSAS) samples were obtained from the ISS in April, June, and July. Analytical methods have not changed from earlier reports, and all quality control measures were met.

  19. A Comparison of Simulation Capabilities for Ducts

    SciTech Connect

    Miller, William A.; Smith, Matt K.; Gu, Lixing; New, Joshua Ryan

    2014-11-01

    Typically, the cheapest way to install a central air conditioning system in residential buildings is to place the ductwork in the attic. Energy losses due to duct-attic interactions can be great, but current whole-house models are unable to capture the dynamic multi-mode physics of the interactions. The building industry is notoriously fragmented and unable to devote adequate research resources to solve this problem. Builders are going to continue to put ducts in the attic because floor space is too expensive to closet them within living space, and there are both construction and aesthetic issues with other approaches such as dropped ceilings. Thus, there is a substantial need to publicly document duct losses and the cost of energy used by ducts in attics so that practitioners, builders, homeowners and state and federal code officials can make informed decisions leading to changes in new construction and additional retrofit actions. Thus, the goal of this study is to conduct a comparison of AtticSim and EnergyPlus simulation algorithms to identify specific features for potential inclusion in EnergyPlus that would allow higher-fidelity modeling of HVAC operation and duct transport of conditioned air. It is anticipated that the resulting analysis from these simulation tools will inform energy decisions relating to the role of ducts in future building energy codes and standards.

  20. Evaluation of DNA damage in exfoliated tear duct epithelial cells from individuals exposed to air pollution assessed by single cell gel electrophoresis assay.

    PubMed

    Rojas, E; Valverde, M; Lopez, M C; Naufal, I; Sanchez, I; Bizarro, P; Lopez, I; Fortoul, T I; Ostrosky-Wegman, P

    2000-06-22

    The search for relevant target cells for human monitoring purposes has increased during the last few years. Cells such as sperm, buccal or nasal and gastric epithelium are being used. In this study, we report the use of exfoliated tear duct epithelial cells as a potential material for human biomonitoring studies, since these cells are a target for environmental pollutants. We employed the alkaline single cell gel electrophoresis (SCGE) assay to evaluate for differences in the basal level of DNA damage between young adults from the south (exposed mainly to high levels of ozone) and from the north (exposed principally to hydrocarbons) regions of Mexico City. We found an increase in DNA migration in tear duct epithelial cells from individuals who live in the southern part of the city compared to those living in the northern part. Moreover, young people who live in the southwest part of the city with the highest values of ozone presented the highest values of DNA damage. These results show the feasibility of using exfoliated tear duct epithelial cells in human biomonitoring studies. PMID:10863153

  1. Numerical simulation of duct flow with fog droplets

    NASA Astrophysics Data System (ADS)

    Suryan, Abhilash; Lee, J. K.; Kim, D. S.; Kim, H. D.

    2010-12-01

    Evaporative cooling is a widely used air cooling technique. In this method, evaporation of a liquid in the surrounding air cools the air in contact with it. In the current investigation, numerical simulations are carried out to visualize the evaporation and dynamics of tiny water droplets of different diameters in a long air duct. The effect of initial droplet size on the temperature and relative humidity distribution of the air stream in the duct is investigated. Three different initial conditions of air are considered to verify the influence of ambient conditions. Droplet spray patterns are also analyzed to identify the suitable locations for the spray nozzles within the duct. The results obtained are displayed in a series of plots to provide a clear understanding of the evaporative cooling process as well as the droplet dynamics within the ducts.

  2. Lightweight Valve Closes Duct Quickly

    NASA Technical Reports Server (NTRS)

    Fournier, Walter L.; Burgy, N. Frank

    1991-01-01

    Expanding balloon serves as lightweight emergency valve to close wide duct. Uninflated balloon stored in housing of duct. Pad resting on burst diaphragm protects balloon from hot gases in duct. Once control system triggers valve, balloon inflates rapidly to block duct. Weighs much less than does conventional butterfly, hot-gas, or poppet valve capable of closing duct of equal diameter.

  3. Assessment of Air Quality in the Shuttle and International Space Station (ISS) Based on Samples Returned by STS-105 at the Conclusion of 7A.1

    NASA Technical Reports Server (NTRS)

    James, John T.

    2001-01-01

    The toxicological assessment of air samples returned at the end of the STS-105 (7 A.1) flight to the ISS is reported. ISS air samples were taken in August 2001 from the Service Module, FGB, and U.S. Laboratory using grab sample canisters (GSCs) and/or formaldehyde badges. Preflight and end-of-mission samples were obtained from Discovery using GSCs. Analytical methods have not changed from earlier reports, and surrogate standard recoveries were 64-115%. Pressure tracking indicated no leaks in the canisters.

  4. Experiments measuring particle deposition from fully developed turbulent flow in ventilation ducts

    SciTech Connect

    Sippola, Mark R.; Nazaroff, William W.

    2003-08-01

    Particle deposition in ventilation ducts influences particle exposures of building occupants and may lead to a variety of indoor air quality concerns. Experiments have been performed in a laboratory to study the effects of particle size and air speed on deposition rates of particles from turbulent air flows in galvanized steel and internally insulated ducts with hydraulic diameters of 15.2 cm. The duct systems were constructed of materials typically found in commercial heating, ventilating and air conditioning (HVAC) systems. In the steel duct system, experiments with nominal particle sizes of 1, 3, 5, 9 and 16 {micro}m were conducted at each of three nominal air speeds: 2.2, 5.3 and 9.0 m/s. In the insulated duct system, deposition rates of particles with nominal sizes of 1, 3, 5, 8 and 13 {micro}m were measured at nominal air speeds of 2.2, 5.3 and 8.8 m/s. Fluorescent techniques were used to directly measure the deposition velocities of monodisperse fluorescent particles to duct surfaces (floor, wall and ceiling) at two straight duct sections where the turbulent flow profile was fully developed. In steel ducts, deposition rates were higher to the duct floor than to the wall, which were, in turn, greater than to the ceiling. In insulated ducts, deposition was nearly the same to the duct floor, wall and ceiling for a given particle size and air speed. Deposition to duct walls and ceilings was greatly enhanced in insulated ducts compared to steel ducts. Deposition velocities to each of the three duct surface orientations in both systems were found to increase with increasing particle size or air velocity over the ranges studied. Deposition rates measured in the current experiments were in general agreement with the limited observations of similar systems by previous researchers.

  5. SNM holdup assessment of Los Alamos exhaust ducts. Final report

    SciTech Connect

    Marshall, R.S.

    1994-02-01

    Fissile material holdup in glovebox and fume hood exhaust ducting has been quantified for all Los Alamos duct systems. Gamma-based, nondestructive measurements were used to quantify holdup. The measurements were performed during three measurement campaigns. The first campaign, Phase I, provided foot-by-foot, semiquantitative measurement data on all ducting. These data were used to identify ducting that required more accurate (quantitative) measurement. Of the 280 duct systems receiving Phase I measurements, 262 indicated less than 50 g of fissile holdup and 19 indicated fissile holdup of 50 or more grams. Seven duct systems were measured in a second campaign, called Series 1, Phase II. Holdup estimates on these ducts ranged from 421 g of {sup 235}U in a duct servicing a shut-down uranium-machining facility to 39 g of {sup 239}Pu in a duct servicing an active plutonium-processing facility. Measurements performed in the second campaign proved excessively laborious, so a third campaign was initiated that used more efficient instrumentation at some sacrifice in measurement quality. Holdup estimates for the 12 duct systems measured during this third campaign ranged from 70 g of {sup 235}U in a duct servicing analytical laboratories to 1 g of {sup 235}U and 1 g of {sup 239}Pu in a duct carrying exhaust air to a remote filter building. These quantitative holdup estimates support the conclusion made at the completion of the Phase I measurements that only ducts servicing shut-down uranium operations contain about 400 g of fissile holdup. No ventilation ducts at Los Alamos contain sufficient fissile material holdup to present a criticality safety concern.

  6. Ducted auroral kilometric radiation

    NASA Technical Reports Server (NTRS)

    Calvert, W.

    1982-01-01

    Certain discrete, intense wave signals attributed to auroral kilometric radiation (AKR) were observed with ISEE-l while it was within the plasmaspheric shadow zone for direct propagation. It is believed that wave ducting by thin depletions of the plasma density aligned with the magnetic field accounts for such signals, and that their discrete nature is caused by the satellite intercepting individual ducts. These ducts, which were also observed as coincident decreases of the upper hybrid resonance frequency, appeared to be twenty-percent depletions roughly one hundred kilometers across. The AKR, which is emitted approximately perpendicular to the magnetic field, apparently entered these ducts equatorward of the source after the waves had been refracted parallel to the duct axis. A diffuse background was also observed which is consistent with the leakage from similar ducts at lower L-values. These observations establish the existence of ducted AKR, its signature on the satellite wave spectrograms, and new evidence for depletion ducts within the plasmasphere.

  7. Duct Leakage Repeatability Testing

    SciTech Connect

    Walker, Iain; Sherman, Max

    2014-01-01

    Duct leakage often needs to be measured to demonstrate compliance with requirements or to determine energy or Indoor Air Quality (IAQ) impacts. Testing is often done using standards such as ASTM E1554 (ASTM 2013) or California Title 24 (California Energy Commission 2013 & 2013b), but there are several choices of methods available within the accepted standards. Determining which method to use or not use requires an evaluation of those methods in the context of the particular needs. Three factors that are important considerations are the cost of the measurement, the accuracy of the measurement and the repeatability of the measurement. The purpose of this report is to evaluate the repeatability of the three most significant measurement techniques using data from the literature and recently obtained field data. We will also briefly discuss the first two factors. The main question to be answered by this study is to determine if differences in the repeatability of these tests methods is sufficient to indicate that any of these methods is so poor that it should be excluded from consideration as an allowed procedure in codes and standards.

  8. Strategy Guideline: Compact Air Distribution Systems

    SciTech Connect

    Burdick, A.

    2013-06-01

    This Strategy Guideline discusses the benefits and challenges of using a compact air distribution system to handle the reduced loads and reduced air volume needed to condition the space within an energy efficient home. Traditional systems sized by 'rule of thumb' (i.e., 1 ton of cooling per 400 ft2 of floor space) that 'wash' the exterior walls with conditioned air from floor registers cannot provide appropriate air mixing and moisture removal in low-load homes. A compact air distribution system locates the HVAC equipment centrally with shorter ducts run to interior walls, and ceiling supply outlets throw the air toward the exterior walls along the ceiling plane; alternatively, high sidewall supply outlets throw the air toward the exterior walls. Potential drawbacks include resistance from installing contractors or code officials who are unfamiliar with compact air distribution systems, as well as a lack of availability of low-cost high sidewall or ceiling supply outlets to meet the low air volumes with good throw characteristics. The decision criteria for a compact air distribution system must be determined early in the whole-house design process, considering both supply and return air design. However, careful installation of a compact air distribution system can result in lower material costs from smaller equipment, shorter duct runs, and fewer outlets; increased installation efficiencies, including ease of fitting the system into conditioned space; lower loads on a better balanced HVAC system, and overall improved energy efficiency of the home.

  9. Assessment of Air Quality in the Shuttle and International Space Station (ISS) Based on Samples Returned by STS-102 at the Conclusion of 5A.1

    NASA Technical Reports Server (NTRS)

    James, John T.

    2001-01-01

    The toxicological assessment of air samples returned at the end of the STS-102 (5A.1) flight to the ISS is reported. ISS air samples were taken in late February 2001 from the Service Module, FGB, and U.S. Laboratory using grab sample canisters (GSCs) and/or formaldehyde badges . A "first-entry" sample of the multipurpose logistics module (MPLM) atmosphere was taken with a GSC, and preflight and end-of-mission samples were obtained from Discovery using GSCs. Analytical methods have not changed from earlier reports, and all quality control measures were met for the data presented herein. The two general criteria used to assess air quality are the total-non-methane-volatile organic hydrocarbons (NMVOCs) and the total T-value (minus the CO2 contribution). Control of atmospheric alcohols is important to the water recovery system engineers, hence total alcohols were also assessed in each sample. Formaldehyde is quantified separately.

  10. Investigation of the tone-burst tube for duct lining attenuation measurement

    NASA Technical Reports Server (NTRS)

    Soffel, A. R.; Morrow, P. F.

    1972-01-01

    The tone burst technique makes practical the laboratory evaluation of potential inlet and discharge duct treatments. Tone burst apparatus requires only simple machined parts and standard components. Small, simply made, lining samples are quickly and easily installed in the system. Two small electromagnetric loudspeaker drivers produce peak sound pressure level of over 166 db in the 3-square-inch sample duct. Air pump available in most laboratories can produce air flows of over plus and minus Mach 0.3 in the sample duct. The technique uses short shaped pulses of sound propagated down a progressive wave tube containing the sample duct. The peak pressure level output of the treated duct is compared with the peak pressure level output of a substituted reference duct. The difference between the levels is the attenuation or insertion loss of the treated duct. Evaluations of resonant absorber linings by the tone burst technique check attenuation values predicted by empirical formulas based on full scale ducts.

  11. HVAC pipe/duct sizing using artificial neural networks

    SciTech Connect

    Yeh, S.J.D.; Wong, K.F.V.

    1995-12-31

    The main objective of this study is to demonstrate that artificial neural networks (ANN`s) serve as useful aids to Heating, Ventilating and Air-Conditioning (HVAC) system design. In the present work, the design process for sizing fluid systems in HVAC is simulated by using ANN`S. Four ANN`s have been constructed in a personal computer, one for air duct sizing and three for pipe sizing. The air duct network was trained to output the friction rate and duct size. The three pipe sizing neural networks product pressure drops and pipe diameters. By using the trained artificial neural networks, data can be obtained instantly with errors less than 3%. Thus, ANN`s have been shown to simplify traditional methods and procedures in HVAC pipe and air duct sizing.

  12. Primary zone air proportioner

    DOEpatents

    Cleary, Edward N. G.

    1982-10-12

    An air proportioner is provided for a liquid hydrocarbon fueled gas turbine of the type which is convertible to oil gas fuel and to coal gas fuel. The turbine includes a shell for enclosing the turbine, an air duct for venting air in said shell to a gasifier, and a fuel injector for injecting gasified fuel into the turbine. The air proportioner comprises a second air duct for venting air from the air duct for mixing with fuel from the gasifier. The air can be directly injected into the gas combustion basket along with the fuel from the injector or premixed with fuel from the gasifier prior to injection by the fuel injector.

  13. Better Duct Systems for Home Heating and Cooling

    SciTech Connect

    Not Available

    2004-11-01

    Duct systems used in forced-air space-conditioning systems are a vital element in home energy efficiency. How well a system works makes a big difference in the cost and the effectiveness of heating and cooling a home. At the same time, a duct system that is poorly designed or maintained can have a detrimental effect on the health of the people who live in the house, through the unintended distribution of indoor air pollution.

  14. Salivary duct stones

    MedlinePlus

    ... glands. Salivary duct stones are a type of salivary gland disorder. ... 83. Jackson NM, Mitchell JL, Walvekar RR. Inflammatory disorders of the salivary glands. In: Flint PW, Haughey BH, Lund LJ, et ...

  15. Determination of the evaporation duct height from standard meteorological data

    NASA Astrophysics Data System (ADS)

    Ivanov, V. K.; Shalyapin, V. N.; Levadnyi, Yu. V.

    2007-02-01

    Four models used for evaluating the height of the evaporation duct from measured atmospheric pressure, water and air temperatures, and air humidity are considered.The calculated results are compared with the duct heights measured during two oceanographic expeditions in the tropical zone of the Atlantic Ocean and the equatorial zone of the Indian Ocean. The sensitivity of models to the errors in the meteorological parameters is investigated. It is shown that, in the case of unstable stratification, the heights of ducts in the 5 20-m range can be evaluated with an error of about 2.5 m. Recommendations for selection of optimal models are given.

  16. Assessment of Air Quality in the International Space Station (ISS) and Space Shuttle Based on Samples Returned Aboard STS-110 (ISS-8A) in April 2002

    NASA Technical Reports Server (NTRS)

    James, John T.

    2002-01-01

    The toxicological assessment of grab sample canisters (GSCs) returned aboard STS-110 is reported. Analytical methods have not changed from earlier reports, and surrogate standard recoveries from the GSCs were 77-121%, with one exception. Pressure tracking indicated no leaks in the canisters. Recoveries from lab and trip controls for formaldehyde analyses ranged from 87 to 96%. The two general criteria used to assess air quality are the total-non-methane-volatile organic hydrocarbons (NMVOCs) and the total T-value (minus the CO2 and formaldehyde contributions). Because of the inertness of Freon 218 (octafluoropropane, OFP), its contribution to the NMVOC is subtracted and tabulated separately. Control of atmospheric alcohols is important to the water recovery system engineers, hence total alcohols are also shown for each sample. Because formaldehyde is quantified from sorbent badges, its concentration is listed separately. These five indices of air quality are summarized.

  17. Film condensation in a horizontal rectangular duct

    NASA Technical Reports Server (NTRS)

    Lu, Qing; Suryanarayana, N. V.

    1993-01-01

    Condensation heat transfer in a horizontal rectangular duct was experimentally and analytically investigated. To prevent the dripping of condensate on the film, the experiment was conducted inside a horizontal rectangular duct with vapor condensing only on the bottom cooled plate of the duct. R-113 and FC-72 (Fluorinert Electronic Fluid developed by the 3M Company) were used as the condensing fluids. The experimental program included measurements of film thickness, local and average heat transfer coefficients, wave length, wave speed, and a study of wave initiation. The measured film thickness was used to obtain the local heat transfer coefficient. The wave initiation was studied both with condensation and with an adiabatic air-liquid flow. The test sections used in both experiments were identical.

  18. Environmental Technology Verification: Supplement to Test/QA Plan for Biological and Aerosol Testing of General Ventilation Air Cleaners; Bioaerosol Inactivation Efficiency by HVAC In-Duct Ultraviolet Light Air Cleaners

    EPA Science Inventory

    The Air Pollution Control Technology Verification Center has selected general ventilation air cleaners as a technology area. The Generic Verification Protocol for Biological and Aerosol Testing of General Ventilation Air Cleaners is on the Environmental Technology Verification we...

  19. Ducts Sealing Using Injected Spray Sealant, Raleigh, North Carolina (Fact Sheet)

    SciTech Connect

    Not Available

    2014-03-01

    In multifamily and attached buildings, traditional duct sealing methods are often impractical or costly and disruptive because of the difficulty in accessing leakage sites. In this project, two retrofit duct sealing techniques - manually-applied sealants and injecting a spray sealant, were implemented in several low-rise multi-unit buildings. An analysis on the cost and performance of the two methods are presented. Each method was used in twenty housing units: approximately half of each group of units are single story and the remainder two-story. Results show that duct leakage to the outside was reduced by an average of 59% through the use of manual methods, and by 90% in the units where the injected spray sealant was used. It was found that 73% of the leakage reduction in homes that were treated with injected spray sealant was attributable to the manual sealing done at boots, returns and the air handler. The cost of manually-applying sealant ranged from $275 to $511 per unit and for the injected spray sealant the cost was $700 per unit. Modeling suggests a simple payback of 2.2 years for manual sealing and 4.7 years for the injected spray sealant system. Utility bills were collected for one year before and after the retrofits. Utility bill analysis shows 14% and 16% energy savings using injected spray sealant system and hand sealing procedure respectively in heating season whereas in cooling season, energy savings using injected spray sealant system and hand sealing were both 16%.

  20. Patent arterial duct

    PubMed Central

    Forsey, Jonathan T; Elmasry, Ola A; Martin, Robin P

    2009-01-01

    Patent arterial duct (PAD) is a congenital heart abnormality defined as persistent patency in term infants older than three months. Isolated PAD is found in around 1 in 2000 full term infants. A higher prevalence is found in preterm infants, especially those with low birth weight. The female to male ratio is 2:1. Most patients are asymptomatic when the duct is small. With a moderate-to-large duct, a characteristic continuous heart murmur (loudest in the left upper chest or infraclavicular area) is typical. The precordium may be hyperactive and peripheral pulses are bounding with a wide pulse pressure. Tachycardia, exertional dyspnoea, laboured breathing, fatigue or poor growth are common. Large shunts may lead to failure to thrive, recurrent infection of the upper respiratory tract and congestive heart failure. In the majority of cases of PAD there is no identifiable cause. Persistence of the duct is associated with chromosomal aberrations, asphyxia at birth, birth at high altitude and congenital rubella. Occasional cases are associated with specific genetic defects (trisomy 21 and 18, and the Rubinstein-Taybi and CHARGE syndromes). Familial occurrence of PAD is uncommon and the usual mechanism of inheritance is considered to be polygenic with a recurrence risk of 3%. Rare families with isolated PAD have been described in which the mode of inheritance appears to be dominant or recessive. Familial incidence of PAD has also been linked to Char syndrome, familial thoracic aortic aneurysm/dissection associated with patent arterial duct, and familial patent arterial duct and bicuspid aortic valve associated with hand abnormalities. Diagnosis is based on clinical examination and confirmed with transthoracic echocardiography. Assessment of ductal blood flow can be made using colour flow mapping and pulsed wave Doppler. Antenatal diagnosis is not possible, as PAD is a normal structure during antenatal life. Conditions with signs and symptoms of pulmonary overcirculation

  1. Patent arterial duct.

    PubMed

    Forsey, Jonathan T; Elmasry, Ola A; Martin, Robin P

    2009-01-01

    Patent arterial duct (PAD) is a congenital heart abnormality defined as persistent patency in term infants older than three months. Isolated PAD is found in around 1 in 2000 full term infants. A higher prevalence is found in preterm infants, especially those with low birth weight. The female to male ratio is 2:1. Most patients are asymptomatic when the duct is small. With a moderate-to-large duct, a characteristic continuous heart murmur (loudest in the left upper chest or infraclavicular area) is typical. The precordium may be hyperactive and peripheral pulses are bounding with a wide pulse pressure. Tachycardia, exertional dyspnoea, laboured breathing, fatigue or poor growth are common. Large shunts may lead to failure to thrive, recurrent infection of the upper respiratory tract and congestive heart failure. In the majority of cases of PAD there is no identifiable cause. Persistence of the duct is associated with chromosomal aberrations, asphyxia at birth, birth at high altitude and congenital rubella. Occasional cases are associated with specific genetic defects (trisomy 21 and 18, and the Rubinstein-Taybi and CHARGE syndromes). Familial occurrence of PAD is uncommon and the usual mechanism of inheritance is considered to be polygenic with a recurrence risk of 3%. Rare families with isolated PAD have been described in which the mode of inheritance appears to be dominant or recessive. Familial incidence of PAD has also been linked to Char syndrome, familial thoracic aortic aneurysm/dissection associated with patent arterial duct, and familial patent arterial duct and bicuspid aortic valve associated with hand abnormalities. Diagnosis is based on clinical examination and confirmed with transthoracic echocardiography. Assessment of ductal blood flow can be made using colour flow mapping and pulsed wave Doppler. Antenatal diagnosis is not possible, as PAD is a normal structure during antenatal life. Conditions with signs and symptoms of pulmonary overcirculation

  2. Converting dual-duct constant-volume systems to variable-volume systems without retrofitting the terminal boxes

    SciTech Connect

    Liu, M.; Claridge, D.E.

    1999-07-01

    Dual-duct constant-air-volume systems can be converted to variable-air-volume systems by installing hot air dampers in the main hot air ducts. No terminal box retrofit is needed. The detailed retrofit procedures and control sequences are described in this paper. Results from a case study building are also presented.

  3. Detonation duct gas generator demonstration program

    NASA Technical Reports Server (NTRS)

    Wortman, Andrew; Brinlee, Gayl A.; Othmer, Peter; Whelan, Michael A.

    1991-01-01

    The feasibility of the generation of detonation waves moving periodically across high speed channel flow is experimentally demonstrated. Such waves are essential to the concept of compressing requirements and increasing the engine pressure compressor with the objective of reducing conventional compressor requirements and increasing the engine thermodynamic efficiency through isochoric energy addition. By generating transient transverse waves, rather than standing waves, shock wave losses are reduced by an order of magnitude. The ultimate objective is to use such detonation ducts downstream of a low pressure gas turbine compressor to produce a high overall pressure ratio thermodynamic cycle. A 4 foot long, 1 inch x 12 inch cross-section, detonation duct was operated in a blow-down mode using compressed air reservoirs. Liquid or vapor propane was injected through injectors or solenoid valves located in the plenum or the duct itself. Detonation waves were generated when the mixture was ignited by a row of spark plugs in the duct wall. Problems with fuel injection and mixing limited the air speeds to about Mach 0.5, frequencies to below 10 Hz, and measured pressure ratios of about 5 to 6. The feasibility of the gas dynamic compression was demonstrated and the critical problem areas were identified.

  4. Turbofan Duct Propagation Model

    NASA Technical Reports Server (NTRS)

    Lan, Justin H.; Posey, Joe W. (Technical Monitor)

    2001-01-01

    The CDUCT code utilizes a parabolic approximation to the convected Helmholtz equation in order to efficiently model acoustic propagation in acoustically treated, complex shaped ducts. The parabolic approximation solves one-way wave propagation with a marching method which neglects backwards reflected waves. The derivation of the parabolic approximation is presented. Several code validation cases are given. An acoustic lining design process for an example aft fan duct is discussed. It is noted that the method can efficiently model realistic three-dimension effects, acoustic lining, and flow within the computational capabilities of a typical computer workstation.

  5. Air

    MedlinePlus

    ... do to protect yourself from dirty air . Indoor air pollution and outdoor air pollution Air can be polluted indoors and it can ... this chart to see what things cause indoor air pollution and what things cause outdoor air pollution! Indoor ...

  6. Gas turbine engine and its associated air intake system

    SciTech Connect

    Ballard, J.R.; Bennett, G.H.; Lee, L.A.

    1984-01-17

    A gas turbine engine and its associated air intake system are disclosed in which the air intake system comprises a generally horizontally extending duct through which an airflow is induced by an ejector pump powered by the engine. A portion of the air passing through the duct is directed through a second duct to the air inlet of the engine. The second duct is connected to the first duct in such a manner that the air directed to the engine air inlet is derived from a vertically upper region of the first duct. The arrangement is intended to reduce the amount of airborne particulate material ingested by the gas turbine engine.

  7. Seasonal variations of surface duct conditions in Ngaoundere, North Cameroon

    NASA Astrophysics Data System (ADS)

    Kaissassou, Samuel; Lenouo, André; Nzeukou, Armand; Tchawoua, Clément; Vondou, D. A.

    2015-12-01

    The seasonal variations of refractivity gradients from 104 to 3000 m above ground level in the troposphere layer are presented based on observations from the radiosonde station located in Ngaoundere (13.5°E, 7.3°N), a middle belt savannah region of Cameroon. Six years (2006-2011) of data from in situ measurements made by Agency for the Safety of Air Navigation in Africa and Madagascar (ASECNA) of the temperature, moisture, and pressure are used to determine the surface duct conditions over Ngaoundere region. Each time that a negative gradient from the Abel-retrieved refractivity profiles is seen, it implies the presence of a duct in this study. The occurrence of ducts strongly depends on the local climate and synoptic weather conditions which have an appreciable influence on the refractivity vertical profile, especially the seasonal north-south movement of the Inter Tropical Convergence Zone (ITCZ) which provides wet and dry seasons to the region. Monthly and seasonal variations of ducts were also determined from the measured data. The highest and the lowest occurrence rate of surface ducts were observed during the wet and the dry seasons, respectively. September appears as the month when most of the ducts occur at the rate of at least one duct per day. The median duct thickness and duct strength are high and strong during the wet season, whereas they are low and weak during the dry season. When the data are separated into stable and unstable atmospheric conditions, we noticed that surface duct characteristics show some seasonal differences. Surface ducts are found to be more frequent in a stable atmosphere than in an unstable atmosphere. Statistical results are discussed alongside with local meteorological conditions and weather systems affecting the town of Ngaoundere. Besides, comments are made on their prospective significance in the region.

  8. Assessment of Air Quality in the Shuttle and International Space Station (ISS) Based on Samples Returned by STS-100 at the Conclusion of 6A

    NASA Technical Reports Server (NTRS)

    James, John T.

    2001-01-01

    The toxicological assessment of air samples returned at the end of the STS-100 (6A) flight to the ISS is reported. ISS air samples were taken in March and April 2001 from the Service Module, FGB, and U.S. Laboratory using grab sample canisters (GSCs) and/or formaldehyde badges. An unplanned "first-entry" sample of the MPLM2 (multipurpose logistics module) atmosphere was taken with a GSC, and preflight and end-of-mission samples were obtained from Endeavour using GSCs. Analytical methods have not changed from earlier reports, and all quality control measures were met for the data presented herein. The two general criteria used to assess air quality are the total-non-methane-volatile organic hydrocarbons (NMVOCs) and the total T-value (minus the CO2 and formaldehyde contribution). Because of the Freon 218 (octafluoropropane, OFP) leak, its contribution to the NMVOC is indicated in brackets. When comparing the NMVOC values with the 25 mg/cubic m guideline, the OFP contributions should be subtracted. Control of atmospheric alcohols is important to the water recovery system engineers, hence total alcohols were also assessed in each sample.

  9. What Is Bile Duct Cancer?

    MedlinePlus

    ... of bile duct cancer. The rest of this document refers only to cholangiocarcinomas. Benign bile duct tumors ... tumors, which aren’t discussed further in this document. Other cancers in the liver The most common ...

  10. Dynamic instability of ducts conveying fluid

    NASA Technical Reports Server (NTRS)

    Yu, Y. Y.

    1975-01-01

    A finite element analysis was used to study dynamic instability in ducts conveying high speed fluids. Ducts examined include cantilevered curved, flexibly supported, arbitrarily shaped, and composite duct systems. Partial differential equations were used to study the duct systems.

  11. Lidar description of the evaporative duct in ocean environments

    NASA Astrophysics Data System (ADS)

    Willitsford, Adam; Philbrick, C. R.

    2005-08-01

    The description of radar propagation in the presence of the evaporation duct has proven to be a difficult problem in both littoral and open ocean environments. To properly characterize the propagation of a radar beam at low elevation angles, the evaporation duct must be located and scattering properties quantified. The two key elements defining an evaporation duct are the gradients in density and specific humidity. The gradients of the neutral density are determined from the rotational Raman temperature profile. The profile of water vapor is measured directly from the vibrational Raman scattered returns. High spatial resolution and high temporal resolution measurements of water vapor and temperature are required to accurately describe the evaporation duct. Raman lidar techniques can provide these measurements continuously with high accuracy and high resolution so the development of the evaporation duct can be studied. A detailed simulation of a Raman lidar has been developed and applied to a near horizontal path, to examine the expected accuracy for high vertical resolution profiles. The simulation also allows various atmospheric scenarios to be investigated and analyzed. The evaporation duct is an atmospheric phenomenon that causes radar propagation to remain trapped in the surface layer. The duct can be thought of as a waveguide that bends and reflects the radar beam along a path effectively trapping it and guiding it over long distances. This is a major problem for radar propagation paths in both littoral and open ocean environments. Moreover, ducting skews details of radar returns such that radar objects are hidden, or are detected at unexpected distances, or may appear with apparent cross-sections and speeds much different than their actual values.

  12. Ducted fan type gas turbine engine power plants

    SciTech Connect

    Balzer, R.L.

    1992-02-25

    This patent describes a ducted fan type power plant which is cable of generating reverse thrust. It comprises: a gas turbine engine; a fan driven by the engine; an elongated bypass duct which is open at its front and rear ends and surrounds the fan, the bypass duct having a fixed forward section and a rear section which can be translated away from the fixed section as the pitch of the fan blades is reversed to reverse the flow of air through the bypass duct and generate a thrust directed from the front toward the rear of the power plant, thereby allowing air to be induced into the bypass duct through the downstream end thereof and also through the annular gap between the fixed and translated, rear sections of the bypass duct; means for generating a supply of high velocity fluid; means for injecting the high velocity fluid into the bypass duct from a locus to the rear means for delivering the high velocity fluid from the generating means to the injecting means.

  13. Duct Leakage Repeatability Testing

    SciTech Connect

    Walker, Iain; Sherman, Max

    2014-08-01

    The purpose of this report is to evaluate the repeatability of the three most significant measurement techniques for duct leakage using data from the literature and recently obtained field data. We will also briefly discuss the first two factors. The main question to be answered by this study is to determine if differences in the repeatability of these tests methods is sufficient to indicate that any of these methods is so poor that it should be excluded from consideration as an allowed procedure in codes and standards. The three duct leak measurement methods assessed in this report are the two duct pressurization methods that are commonly used by many practitioners and the DeltaQ technique. These are methods B, C and A, respectively of the ASTM E1554 standard. Although it would be useful to evaluate other duct leak test methods, this study focused on those test methods that are commonly used and are required in various test standards, such as BPI (2010), RESNET (2014), ASHRAE 62.2 (2013), California Title 24 (CEC 2012), DOE Weatherization and many other energy efficiency programs.

  14. EFFECT OF AIRFLOW AND HEAT INPUT RATES ON DUCT EFFICIENCY.

    SciTech Connect

    ANDREWS,J.W.

    2003-05-28

    Reducing the airflow and heat input rates of a furnace that is connected to a duct system in thermal contact with unconditioned spaces can significantly reduce thermal distribution efficiency. This is a straightforward theoretical calculation based on the increased residence time of the air in the duct at the lower flow rate, which results in greater conduction losses. Experimental tests in an instrumented residential-size duct system have confirmed this prediction. Results are compared with the heat-loss algorithm in ASHRAE Standid 152P. The paper concludes with a discussion of possible remedies for this loss of efficiency in existing systems and optional design strategies in new construction.

  15. STS 129 Return Samples: Assessment of Air Quality aboard the Shuttle (STS-129) and International Space Station (ULF3)

    NASA Technical Reports Server (NTRS)

    James, John T.

    2010-01-01

    Reports on the air quality aboard the Space Shuttle (STS-129), and the International Space station (ULF3). NASA analyzed the grab sample canisters (GSCs) and the formaldehyde badges aboard both locations for carbon monoxide levels. The three surrogates: (sup 13)C-acetone, fluorobenzene, and chlorobenzene registered 109, 101, and 109% in the space shuttle and 81, 87, and 55% in the International Space Station (ISS). From these results the atmosphere in both the Space Shuttle and the International Space Station (ISS) was found to be breathable.

  16. Heat Transfer in a Superelliptic Transition Duct

    NASA Technical Reports Server (NTRS)

    Poinsatte, Philip; Thurman, Douglas; Hippensteele, Steven

    2008-01-01

    Local heat transfer measurements were experimentally mapped using a transient liquid-crystal heat transfer technique on the surface of a circular-to-rectangular transition duct. The transition duct had a length-to-diameter ratio of 1.5 and an exit-plane aspect ratio of 3. The crosssectional geometry was defined by the equation of a superellipse. The cross-sectional area was the same at the inlet and exit but varied up to 15 percent higher through the transition. The duct was preheated to a uniform temperature (nominally 64 C) before allowing room temperature air to be suddenly drawn through it. As the surface cooled, the resulting isothermal contours on the duct surface were revealed using a surface coating of thermochromic liquid crystals that display distinctive colors at particular temperatures. A video record was made of the surface temperature and time data for all points on the duct surfaces during each test. Using this surface temperature-time data together with the temperature of the air flowing through the model and the initial temperature of the model wall, the heat transfer coefficient was calculated by employing the classic one-dimensional, semi-infinite wall heat transfer conduction model. Test results are reported for inlet diameter-based Reynolds numbers ranging from 0.4x106 to 2.4x106 and two grid-generated freestream turbulence intensities of about 1 percent, which is typical of wind tunnels, and up to 16 percent, which may be more typical of real engine conditions.

  17. Compact Buried Ducts in a Hot-Humid Climate House

    SciTech Connect

    Mallay, D.

    2016-01-01

    A system of compact, buried ducts provides a high-performance and cost-effective solution for delivering conditioned air throughout the building. This report outlines research activities that are expected to facilitate adoption of compact buried duct systems by builders. The results of this research would be scalable to many new house designs in most climates and markets, leading to wider industry acceptance and building code and energy program approval.

  18. Efficiency of shock wave attenuation in ducts by various methods

    NASA Astrophysics Data System (ADS)

    Frolov, S. M.

    1993-02-01

    Different methods of shock wave attenuation in ducts are compared in terms of efficiency. The methods investigated include expansion of the duct cross section, the use of perforated side walls, and the use of porous screens and screen cascades. The attentuation of air shock waves is estimated by using a unified approach which provides satisfactory agreement with experimental data. Based on the results of the study, a nomogram is plotted which can be used for practical calculations.

  19. Measure Guideline: Summary of Interior Ducts in New Construction, Including an Efficient, Affordable Method to Install Fur-Down Interior Ducts

    SciTech Connect

    Beal, D.; McIlvaine , J.; Fonorow, K.; Martin, E.

    2011-11-01

    This document illustrates guidelines for the efficient installation of interior duct systems in new housing, including the fur-up chase method, the fur-down chase method, and interior ducts positioned in sealed attics or sealed crawl spaces. This document illustrates guidelines for the efficient installation of interior duct systems in new housing. Interior ducts result from bringing the duct work inside a home's thermal and air barrier. Architects, designers, builders, and new home buyers should thoroughly investigate any opportunity for energy savings that is as easy to implement during construction, such as the opportunity to construct interior duct work. In addition to enhanced energy efficiency, interior ductwork results in other important advantages, such as improved indoor air quality, increased system durability and increased homeowner comfort. While the advantages of well-designed and constructed interior duct systems are recognized, the implementation of this approach has not gained a significant market acceptance. This guideline describes a variety of methods to create interior ducts including the fur-up chase method, the fur-down chase method, and interior ducts positioned in sealed attics or sealed crawl spaces. As communication of the intent of an interior duct system, and collaboration on its construction are paramount to success, this guideline details the critical design, planning, construction, inspection, and verification steps that must be taken. Involved in this process are individuals from the design team; sales/marketing team; and mechanical, insulation, plumbing, electrical, framing, drywall and solar contractors.

  20. 29. DETAIL OF OUTLET DUCTS FOR MST AIRCONDITIONING SYSTEM IN ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    29. DETAIL OF OUTLET DUCTS FOR MST AIR-CONDITIONING SYSTEM IN NORTHWEST CORNER OF SLC-3W MST STATION 70.5 (LOWEST PAYLOAD SERVICE STATION). NOTE RING ATTACHMENT FOR PERSONNEL SAFETY HARNESS IN LEFT FOREGROUND. - Vandenberg Air Force Base, Space Launch Complex 3, Launch Pad 3 West, Napa & Alden Roads, Lompoc, Santa Barbara County, CA

  1. The flow field of an underexpanded H2 jet coaxially injected into a hot free or ducted supersonic jet of air or nitrogen

    NASA Technical Reports Server (NTRS)

    Jenkins, R. V.

    1977-01-01

    Experimental data obtained in an investigation of the mixing of an underexpanded hydrogen jet in a supersonic flow both with and without combustion are presented. Tests were conducted in a Mach 2 test stream with both air and nitrogen as test media. Total temperature of the test stream was 2170 K, and static exit pressure was about one atmosphere. The static pressure at the exit of the hydrogen injector's Mach 2 nozzle was about two atmospheres. Primary measurements included shadowgraphs and pitot pressure surveys of the flow field. Pitot surveys and wall static pressures were measured for the case where the entire flow was shrouded. The results are compared to similar experimental data and theoretical predictions for the matched pressure case.

  2. 6S Return Samples: Assessment of Air Quality in the International Space Station (ISS) Based on Solid Sorbent Air Sampler (SSAS) and Formaldehyde Monitoring Kit (FMK) Analyses

    NASA Technical Reports Server (NTRS)

    James, John T.

    2004-01-01

    The toxicological assessments of SSAS and FMK analytical results are reported. Analytical methods have not changed from earlier reports. Surrogate standard recoveries from the SSAS tubes were 66-76% for 13C-acetone, 85-96% for fluorobenzene, and 73-89% for chlorobenzene. Post-flight flows were far below pre-flight flows and an investigation of the problem revealed that the reduced flow was caused by a leak at the interface of the pump inlet tube and the pump head. This resulted in degradation of pump efficiency. Further investigation showed that the problem occurred before the SSAS was operated on orbit and that use of the post-flight flows yielded consistent and useful results. Recoveries from formaldehyde control badges were 86 to 104%. The two general criteria used to assess air quality are the total-non-methane-volatile organic hydrocarbons (NMVOCs) and the total T-value (minus the CO2 and formaldehyde contributions). The T values will not be reported for these data due to the flow anomaly. Control of atmospheric alcohols is important to the water recovery system engineers, hence total alcohols (including acetone) are also shown for each sample. Octafluoropropane (OFP) is not efficiently trapped by the sorbents used in the SSAS. Because formaldehyde is quantified from sorbent badges, its concentration is also listed separately. These five indices of air quality are summarized.

  3. Complicated bile duct stones.

    PubMed

    Roy, Ashwin; Martin, Derrick

    2013-01-01

    Common bile duct stones (CBDSs) are solid deposits that can either form within the gallbladder or migrate to the common bile duct (CBD), or form de novo in the biliary tree. In the USA around 15% of the population have gallstones and of these, 3% present with symptoms annually. Because of this, there have been major advancements in the management of gallstones and related conditions. Management is based on the patient's risk profile; young and healthy patients are likely to be recommended for surgery and elderly patients with comorbidities are usually recommended for endoscopic procedures. Imaging of gallstones has advanced in the last 30 years with endoscopic retrograde cholangiopancreatography evolving from a diagnostic to a therapeutic procedure in removing CBDSs. We present a complicated case of a patient with a CBDS and periampullary diverticulum and discuss the techniques used to diagnose and remove the stone from the biliary system. PMID:23946532

  4. Complicated bile duct stones

    PubMed Central

    Roy, Ashwin; Martin, Derrick

    2013-01-01

    Common bile duct stones (CBDSs) are solid deposits that can either form within the gallbladder or migrate to the common bile duct (CBD), or form de novo in the biliary tree. In the USA around 15% of the population have gallstones and of these, 3% present with symptoms annually. Because of this, there have been major advancements in the management of gallstones and related conditions. Management is based on the patient's risk profile; young and healthy patients are likely to be recommended for surgery and elderly patients with comorbidities are usually recommended for endoscopic procedures. Imaging of gallstones has advanced in the last 30 years with endoscopic retrograde cholangiopancreatography evolving from a diagnostic to a therapeutic procedure in removing CBDSs. We present a complicated case of a patient with a CBDS and periampullary diverticulum and discuss the techniques used to diagnose and remove the stone from the biliary system. PMID:23946532

  5. Lacrimal duct cyst abscess.

    PubMed

    Dharmasena, Aruna; Sobajo, Cassandra; Irion, Luciane; Ataullah, Sajid

    2014-12-01

    Cystic dilatation within the lacrimal gland is thought to be related to chronic inflammation and scarring of the lacrimal gland ductules. We review the literature and discuss a case and of lacrimal duct cyst suppuration presenting with visual loss, external ophthalmoplegia, proptosis and ptosis. To our knowledge, only one other report of a lacrimal ductal cyst abscess has been reported in the literature so far. PMID:25208223

  6. Assessment of Air Quality in the International Space Station (ISS) and Space Shuttle Based on Samples Returned Aboard STS-ll1 (UF2) in June 2002

    NASA Technical Reports Server (NTRS)

    James, John T.

    2003-01-01

    The toxicological assessments of grab sample canisters (GSCs) and 2 solid sorbent air samplers (SSASs) returned aboard STS-111 are reported. Analytical methods have not changed from earlier reports. Surrogate standard recoveries from the GSCs were 86-106% and 62% to 136 % from the SSASs; 2 tubes with low surrogate recoveries were not reported. Pressure tracking indicated no leaks in the canisters during analysis. Recoveries from lab and trip controls for formaldehyde analyses ranged from 87 to 96%. The two general criteria used to assess air quality are the total-non-methane-volatile organic hydrocarbons (NMVOCs) and the total T-value (minus the CO2 and formaldehyde contributions). Because of the inertness of Freon 218 (octafluoropropane, OFP), Its contribution to the NMVOC is subtracted and tabulated separately. Control of atmospheric alcohols is important to the water recovery system engineers, hence total alcohols (including acetone) are also shown for each sample. Because formaldehyde is quantified from sorbent badges, its concentration is listed separately. The table shows that the air quality in general was acceptable for crew respiration; however, certain values shown in bold require further explanation. The 1.05 T value on 2/28/02 was caused by an unusually high measurement ofhexamethylcyc1otrisiloxane (T value = 0.50), which is not a concern. The MPLM T value of 1.42 and the alcohol level of 7.5 mg/cu m were due to an overall polluted atmosphere, which was expected at first entry. The major T-value component was carbon monoxide at a contribution of 0.44 units. Since the crew was only exposed momentarily to the polluted atmosphere, no health effects are expected. The formaldehyde value of 0.060 mg/cu m found in the Lab sample from 3/27/02 is cause for concern because the Lab consistently shows higher concentrations of formaldehyde than the SM and occasionally the concentrations are above the acceptable guideline. Levels of OFP have remained low, suggesting

  7. Bile duct malignancies.

    PubMed

    Tucek, S; Tomasek, J; Halámkova, J; Kiss, I; Andrasina, T; Hemmelová, B; Adámková-Krákorová, D; Vyzula, R

    2010-01-01

    Bile duct malignancies include intrahepatic cholangiocarcinoma (ICC), extrahepatic cholangiocarcinoma (ECC), gall bladder carcinoma (GC) and carcinoma of Vater's ampulla (ampulloma). Bile duct neoplasms are rare tumours with overall poor prognosis. The overall incidence affects up to 12.5 per 100,000 persons in the Czech Republic. The mortality rate has risen recently to 9.5 per 100,000 persons. The incidence and mortality have been remarkably stable over the past 3 decades. The survival rate of patients with these tumours is poor, usually not exceeding 12 months. The diagnostic process is complex, uneasy and usually late. Most cases are diagnosed when unresectable, and palliative treatment is the main approach of medical care for these tumours. The treatment remains very challenging. New approaches have not brought much improvement in this field. Standards of palliative care are lacking and quality of life assessments are surprisingly not common. From the scarce data it seems, however, that multimodal individually tailored treatment can prolong patients'survival and improve the health-related quality of life. The care in specialized centres offers methods of surgery, interventional radiology, clinical oncology and high quality supportive care. These methods are discussed in the article in greater detail. Improvements in this field can be sought in new diagnostic methods and new procedures in surgery and interventional radiology. Understanding the tumour biology on the molecular level could shift the strategy to a more successful one, resulting in more cured patients. Further improvements in palliative care can be sought by defining new targets and new drug development. The lack of patients with bile duct neoplasms has been the limiting factor for any improvements. A new design of larger randomized international multicentric clinical trials with prompt data sharing could help to overcome this major problem. Defining standards of palliative care is a necessity

  8. Measure Guideline: Optimizing the Configuration of Flexible Duct Junction Boxes

    SciTech Connect

    Beach, R.; Burdick, A.

    2014-03-01

    This measure guideline offers additional recommendations to heating, ventilation, and air conditioning (HVAC) system designers for optimizing flexible duct, constant-volume HVAC systems using junction boxes within Air Conditioning Contractors of America (ACCA) Manual D guidance (Rutkowski, H. Manual D -- Residential Duct Systems, 3rd edition, Version 1.00. Arlington, VA: Air Conditioning Contractors of America, 2009.). IBACOS used computational fluid dynamics software to explore and develop guidance to better control the airflow effects of factors that may impact pressure losses within junction boxes among various design configurations (Beach, R., Prahl, D., and Lange, R. CFD Analysis of Flexible Duct Junction Box Design. Golden, CO: National Renewable Energy Laboratory, submitted for publication 2013). These recommendations can help to ensure that a system aligns more closely with the design and the occupants' comfort expectations. Specifically, the recommendations described herein show how to configure a rectangular box with four outlets, a triangular box with three outlets, metal wyes with two outlets, and multiple configurations for more than four outlets. Designers of HVAC systems, contractors who are fabricating junction boxes on site, and anyone using the ACCA Manual D process for sizing duct runs will find this measure guideline invaluable for more accurately minimizing pressure losses when using junction boxes with flexible ducts.

  9. Subsonic Flows through S-Ducts with Flow Control

    NASA Astrophysics Data System (ADS)

    Chen, Yi

    An inlet duct of an aircraft connects the air intake mounted on the fuselage to the engine within the aircraft body. The ideal outflow quality of the duct is steady, uniform and of high total pressure. Recently compact S-shaped inlet ducts are drawing more attention in the design of UAVs with short propulsion system. Compact ducts usually involve strong streamwise adverse pressure gradient and transverse secondary flow, leading to large-scale harmful vortical structures in the outflow. To improve the outflow quality modern flow control techniques have to be applied. Before designing successful flow control methods a solid understanding of the baseline flow field with the duct is crucial. In this work the fundamental mechanism of how the three dimensional flow topology evolves when the relevant parameters such as the duct geometry and boundary layer thickness are varied, is studied carefully. Two distinct secondary-flow patterns are identified. For the first time the sensitivity of the flow topology to the inflow boundary layer thickness in long ducts is clearly addressed. The interaction between the transverse motion induced by the transverse pressure gradient and the streamwise separation is revealed as the crucial reason for the various flow patterns existing in short ducts. A non-symmetric flow pattern is identified for the first time in both experiments and simulations in short ducts in which the intensity of the streamwise separation and the transverse invasion are in the same order of magnitude. A theory of energy accumulation and solution bifurcation is used to give a reasonable explanation for this non-symmetry. After gaining the knowledge of where and how the harmful vortical structures are generated several flow control techniques are tested to achieve a better outflow quality. The analysis of the flow control cases also provides a deeper insight into the behavior of the three-dimensional flow within the ducts. The conventional separation control method

  10. Intrahepatic Transposition of Bile Ducts

    PubMed Central

    Delić, Jasmin; Savković, Admedina; Isaković, Eldar; Marković, Sergije; Bajtarevic, Alma; Denjalić, Amir

    2012-01-01

    Objective. To describe the intrahepatic bile duct transposition (anatomical variation occurring in intrahepatic ducts) and to determine the frequency of this variation. Material and Methods. The researches were performed randomly on 100 livers of adults, both sexes. Main research methods were anatomical macrodissection. As a criterion for determination of variations in some parts of bile tree, we used the classification of Segmentatio hepatis according to Couinaud (1957) according to Terminologia Anatomica, Thieme Stuugart: Federative Committee on Anatomical Terminology, 1988. Results. Intrahepatic transposition of bile ducts was found in two cases (2%), out of total examined cases (100): right-left transposition (right segmental bile duct, originating from the segment VIII, joins the left liver duct-ductus hepaticus sinister) and left-right intrahepatic transposition (left segmental bile duct originating from the segment IV ends in right liver duct-ductus hepaticus dexter). Conclusion. Safety and success in liver transplantation to great extent depends on knowledge of anatomy and some common embryological anomalies in bile tree. Variations in bile tree were found in 24–43% of cases, out of which 1–22% are the variations of intrahepatic bile ducts. Therefore, good knowledge on ductal anatomy enables good planning, safe performance of therapeutic and operative procedures, and decreases the risk of intraoperative and postoperative complications. PMID:22550601

  11. Ascariasis of the pancreatic duct.

    PubMed

    Klimovskij, Michail; Dulskas, Audrius; Kraulyte, Zita; Mikalauskas, Saulius

    2015-01-01

    Ascariasis is a common helminthic disease worldwide, although Lithuania and other European countries are not considered endemic areas. The presence of the Ascaris worm in the biliary tree causes choledocholithiasis-like symptoms. We report a case of pancreatic duct ascariasis causing such symptoms. A 73-year-old Lithuanian woman underwent endoscopic retrograde cholangiopancreatography (ERCP) suspecting choledocholithiasis. Contrast injection into the common bile duct demonstrated a slightly dilated biliary tree without any filling defects, and the tail of an Ascaris worm protruding from the opening of the papilla Vater. The worm was captured by a snare but escaped deep into the duct. After a small wirsungotomy the worm was retrieved from the pancreatic duct. The patient received a 150 mg dose of levamisole orally repeated 7 days later and was discharged after complete resolution of symptoms. This first reported sporadic case of pancreatic duct ascariasis in Lithuania was successfully treated with ERCP and Levamisole. PMID:26374772

  12. Measure Guideline: Buried and/or Encapsulated Ducts

    SciTech Connect

    Shapiro, C.; Zoeller, W.; Mantha, P.

    2013-08-01

    Buried and/or encapsulated ducts (BEDs) are a class of advanced, energy-efficiency strategies intended to address the significant ductwork thermal losses associated with ducts installed in unconditioned attics. BEDs are ducts installed in unconditioned attics that are covered in loose-fill insulation and/or encapsulated in closed cell polyurethane spray foam insulation. This Measure Guideline covers the technical aspects of BEDs as well as the advantages, disadvantages, and risks of BEDs compared to other alternative strategies. This guideline also provides detailed guidance on installation of BEDs strategies in new and existing homes through step-by-step installation procedures. This Building America Measure Guideline synthesizes previously published research on BEDs and provides practical information to builders, contractors, homeowners, policy analysts, building professions, and building scientists. Some of the procedures presented here, however, require specialized equipment or expertise. In addition, some alterations to duct systems may require a specialized license. Persons implementing duct system improvements should not go beyond their expertise or qualifications. This guideline provides valuable information for a building industry that has struggled to address ductwork thermal losses in new and existing homes. As building codes strengthen requirements for duct air sealing and insulation, flexibility is needed to address energy efficiency goals. While ductwork in conditioned spaces has been promoted as the panacea for addressing ductwork thermal losses, BEDs installations approach - and sometimes exceed - the performance of ductwork in conditioned spaces.

  13. [A case of lacrimal duct obstruction caused by capecitabine].

    PubMed

    Noguchi, Yusuke; Mitani, Takuya; Kawara, Hiroko; Tokuyama, Yoko; Tamura, Yoshiko; Uchiyama, Kiyoshi; Shimizu, Yoshihiro

    2015-01-01

    In recent years, the incidence of adverse ocular reactions, including corneal problems and lacrimal duct obstruction, due to antineoplastic agents such as S-1 has increased. Very few reports of adverse ocular reactions caused by capecitabine, a fluorinated pyrimidine antineoplastic agent like S-1, exist, and consequently, the mechanism underlying these reactions is not well understood. This report describes our recent experience with a case of lacrimal duct obstruction caused by capecitabine. The patient was a 71-year-old woman who was being administered trastuzumab plus capecitabine combination chemotherapy for breast cancer-related bone metastasis. She complained of epiphora 7 days after capecitabine was initiated. Thereafter, her capecitabine dose was reduced owing to exacerbation of hand-foot syndrome, but the epiphora persisted. Capecitabine was discontinued 287 days after initiation owing to exacerbation of the hand-foot syndrome. However, because the epiphora persisted, the patient visited the ophthalmology department. The ophthalmologist diagnosed the patient with binocular nasolacrimal duct obstruction and cataract, and prescribed a 0.3% gatifloxacin ophthalmic solution and 0.1% fluorometholone ophthalmic suspension. Thereafter, the epiphora reduced. When the patient returned to the ophthalmology department, symptom improvement was confirmed. In this case, lacrimal duct obstruction likely developed due to capecitabine. The symptoms were reversible with discontinuation of capecitabine and ophthalmic treatment. We believe that reporting this case could be valuable in discussing capecitabine-induced lacrimal duct obstruction. PMID:25596694

  14. The impact of duct-to-duct interaction on the hex duct dilation

    SciTech Connect

    Lee, M.J.; Chang, L.K.; Lahm, C.E.; Porter, D.L.

    1992-07-01

    Dilation of the hex duct is an important factor in the operational lifetime of fuel subassemblies in liquid metal fast reactors. It is caused primarily by the irradiation-enhanced creep and void swelling of the hex duct material. Excessive dilation may jeopardize subassembly removal from the core or cause a subassembly storage problem where the grid size of the storage basket is limited. Dilation of the hex duct in Experimental Breeder Reactor II (EBR-II) limits useful lifetime because of these storage basket limitations. It is, therefore, important to understand the hex duct dilation behavior to guide the design and in-core management of fuel subassemblies in a way that excessive duct deformation can be avoided. To investigate the dilation phenomena, finite-element models of the hex duct have been developed. The inelastic analyses were performed using the structural analysis code, ANSYS. Both Type 316 and D9 austenitic stainless steel ducts are considered. The calculated dilations are in good agreement with profilometry measurements made after irradiation. The analysis indicates that subassembly interaction is an important parameter in addition to neutron fluence and temperature in determining hex duct dilation. 5 refs.

  15. Observations of Strong Surface Radar Ducts over the Persian Gulf.

    NASA Astrophysics Data System (ADS)

    Brooks, Ian M.; Goroch, Andreas K.; Rogers, David P.

    1999-09-01

    Ducting of microwave radiation is a common phenomenon over the oceans. The height and strength of the duct are controlling factors for radar propagation and must be determined accurately to assess propagation ranges. A surface evaporation duct commonly forms due to the large gradient in specific humidity just above the sea surface; a deeper surface-based or elevated duct frequently is associated with the sudden change in temperature and humidity across the boundary layer inversion.In April 1996 the U.K. Meteorological Office C-130 Hercules research aircraft took part in the U.S. Navy Ship Antisubmarine Warfare Readiness/Effectiveness Measuring exercise (SHAREM-115) in the Persian Gulf by providing meteorological support and making measurements for the study of electromagnetic and electro-optical propagation. The boundary layer structure over the Gulf is influenced strongly by the surrounding desert landmass. Warm dry air flows from the desert over the cooler waters of the Gulf. Heat loss to the surface results in the formation of a stable internal boundary layer. The layer evolves continuously along wind, eventually forming a new marine atmospheric boundary layer. The stable stratification suppresses vertical mixing, trapping moisture within the layer and leading to an increase in refractive index and the formation of a strong boundary layer duct. A surface evaporation duct coexists with the boundary layer duct.In this paper the authors present aircraft- and ship-based observations of both the surface evaporation and boundary layer ducts. A series of sawtooth aircraft profiles map the boundary layer structure and provide spatially distributed estimates of the duct depth. The boundary layer duct is found to have considerable spatial variability in both depth and strength, and to evolve along wind over distances significant to naval operations (100 km). The depth of the evaporation duct is derived from a bulk parameterization based on Monin-Obukhov similarity theory

  16. Building America Case Study: Duct in Conditioned Space in a Dropped Ceiling or Fur-down, Gainesville, Florida (Fact Sheet)

    SciTech Connect

    Not Available

    2014-09-01

    Forced air distribution systems (duct systems) typically are installed out of sight for aesthetic reasons, most often in unconditioned areas such as an attic or crawlspace. Any leakage of air to or from the duct system (duct leakage) in unconditioned space not only loses energy, but impacts home and equipment durability and indoor air quality. An obvious solution to this problem is to bring the duct system into the interior of the house, either by sealing the area where the ducts are installed (sealed attic or crawlspace) or by building an interior cavity or chase above the ceiling plane (raised ceiling or fur-up chase) or below the ceiling plane (dropped ceiling or fur-down) for the duct system. This case study examines one Building America builder partner's implementation of an inexpensive, quick and effective method of building a fur-down or dropped ceiling chase.

  17. Buoyancy-driven flow reversal phenomena in radially rotating serpentine ducts

    SciTech Connect

    Hwang, J.J.; Wang, W.J.; Chen, C.K.

    2000-02-01

    Convective characteristics are analyzed numerically in a rotating multipass square duct connecting with 180-deg sharp returns. Isoflux is applied to each duct wall and periodic conditions are used between the entrance and exit of a typical two-pass module. Emphasis is placed on the phenomenon of buoyancy-driven reversed flow in the serpentine duct. Predictions reveal that the radial distance from the rotational axis to the location of flow separation in the radial-outward duct decreases with increasing the Richardson number. In addition, the local buoyancy that is required to yield the radial flow reversal increases with increasing the rotation number. This buoyancy-driven reversed flow in the radial-outward duct always results in local hot spots in the cooling channels. The critical buoyancy for the initiation of flow reversal is therefore concluded for the design purpose.

  18. High-Performance Ducts in Hot-Dry Climates

    SciTech Connect

    Hoeschele, Marc; Chitwood, Rick; German, Alea; Weitzel, Elizabeth

    2015-07-30

    Duct thermal losses and air leakage have long been recognized as prime culprits in the degradation of heating, ventilating, and air-conditioning (HVAC) system efficiency. Both the U.S. Department of Energy’s Zero Energy Ready Home program and California’s proposed 2016 Title 24 Residential Energy Efficiency Standards require that ducts be installed within conditioned space or that other measures be taken to provide similar improvements in delivery effectiveness (DE). Pacific Gas & Electric Company commissioned a study to evaluate ducts in conditioned space and high-performance attics (HPAs) in support of the proposed codes and standards enhancements included in California’s 2016 Title 24 Residential Energy Efficiency Standards. The goal was to work with a select group of builders to design and install high-performance duct (HPD) systems, such as ducts in conditioned space (DCS), in one or more of their homes and to obtain test data to verify the improvement in DE compared to standard practice. Davis Energy Group (DEG) helped select the builders and led a team that provided information about HPD strategies to them. DEG also observed the construction process, completed testing, and collected cost data.

  19. DUCT RETROFIT STRATEGY TO COMPLEMENT A MODULATING FURNACE.

    SciTech Connect

    ANDREWS,J.W.

    2002-10-02

    Some recent work (Walker 2001, Andrews 2002) has indicated that installing a modulating furnace in a conventional duct system may, in many cases, result in a significant degradation in thermal distribution efficiency. The fundamental mechanism was pointed out nearly two decades ago (Andrews and Krajewski 1985). The problem occurs in duct systems that are less-than-perfectly insulated (e.g., R-4 duct wrap) and are located outside the conditioned space. It stems from the fact that when the airflow rate is reduced, as it will be when the modulating furnace reduces its heat output rate, the supply air will have a longer residence time in the ducts and will therefore lose a greater percentage of its heat by conduction than it did at the higher airflow rate. The impact of duct leakage, on the other hand, is not expected to change very much under furnace modulation. The pressures in the duct system will be reduced when the airflow rate is reduced, thus reducing the leakage per unit time. This is balanced by the fact that the operating time will increase in order to meet the same heating load as with the conventional furnace operating at higher output and airflow rates. The balance would be exact if the exponent in the pressure vs. airflow equation were the same as that in the pressure vs. duct leakage equation. Since the pressure-airflow exponent is usually {approx}0.5 and the pressure-leakage exponent is usually {approx}0.6, the leakage loss as a fraction of the load should be slightly lower for the modulating furnace. The difference, however, is expected to be small, determined as it is by a function with an exponent equal to the difference between the above two exponents, or {approx}0.1. The negative impact of increased thermal conduction losses from the duct system may be partially offset by improved efficiency of the modulating furnace itself. Also, the modulating furnace will cycle on and off less often than a single-capacity model, and this may add a small amount

  20. PMR Graphite Engine Duct Development

    NASA Technical Reports Server (NTRS)

    Stotler, C. L.; Yokel, S. A.

    1989-01-01

    The objective was to demonstrate the cost and weight advantages that could be obtained by utilizing the graphite/PMR15 material system to replace titanium in selected turbofan engine applications. The first component to be selected as a basis for evaluation was the outer bypass duct of the General Electric F404 engine. The operating environment of this duct was defined and then an extensive mechanical and physical property test program was conducted using material made by processing techniques which were also established by this program. Based on these properties, design concepts to fabricate a composite version of the duct were established and two complete ducts fabricated. One of these ducts was proof pressure tested and then run successfully on a factory test engine for over 1900 hours. The second duct was static tested to 210 percent design limit load without failure. An improved design was then developed which utilized integral composite end flanges. A complete duct was fabricated and successfully proof pressure tested. The net results of this effort showed that a composite version of the outer duct would be 14 percent lighter and 30 percent less expensive that the titanium duct. The other type of structure chosen for investigation was the F404 fan stator assembly, including the fan stator vanes. It was concluded that it was feasible to utilize composite materials for this type structure but that the requirements imposed by replacing an existing metal design resulted in an inefficient composite design. It was concluded that if composites were to be effectively used in this type structure, the design must be tailored for composite application from the outset.

  1. Better Duct Systems for Home Heating and Cooling; Building Technologies Program (Brochure)

    SciTech Connect

    2004-11-01

    Duct systems used in forced-air space-conditioning systems are a vital element in home energy efficiency. How well a system works makes a big difference in the cost and the effectiveness of heating and cooling a home.

  2. Introduction to Indoor Air Quality

    MedlinePlus

    ... as conditions caused by outdoor impacts (such as climate change). Many reports and studies indicate that the following ... Air Duct Cleaning Asthma Health, Energy Efficiency and Climate Change Flood Cleanup Home Remodel Indoor airPLUS Mold Radon ...

  3. Tatanka Returns.

    ERIC Educational Resources Information Center

    Simonelli, Richard

    1993-01-01

    Describes efforts of the InterTribal Bison Cooperative (Rapid City, SD) to reintroduce the buffalo for cultural purposes to American Indian reservations. Explains how the buffalo's return is contributing to community wellness. Discusses career opportunities for both Native and non-Native people in buffalo management. (LP)

  4. Articulated transition duct in turbomachine

    DOEpatents

    Flanagan, James Scott; McMahan, Kevin Weston; LeBegue, Jeffrey Scott; Pentecost, Ronnie Ray

    2014-04-29

    Turbine systems are provided. A turbine system includes a transition duct comprising an inlet, an outlet, and a duct passage extending between the inlet and the outlet and defining a longitudinal axis, a radial axis, and a tangential axis. The outlet of the transition duct is offset from the inlet along the longitudinal axis and the tangential axis. The duct passage includes an upstream portion and a downstream portion. The upstream portion extends from the inlet between an inlet end and an aft end. The downstream portion extends from the outlet between an outlet end and a head end. The turbine system further includes a joint coupling the aft end of the upstream portion and the head end of the downstream portion together. The joint is configured to allow movement of the upstream portion and the downstream portion relative to each other about or along at least one axis.

  5. Wave reflections from duct terminations.

    PubMed

    Selamet, A; Ji, Z L; Kach, R A

    2001-04-01

    The reflection coefficients and inertial end corrections of several duct terminations, including finite length duct extensions perpendicular to an infinite wall, as well as at a number of angles, curved interface surfaces, and annular cavities, are determined and analyzed in the absence of flow by employing the boundary element method. Predictions for the classical unflanged and flanged circular ducts show good agreement with analytical and computational results available in the literature. The predictions for curved interface surfaces (bellmouth or horn) are also consistent with the available experimental data. In view of its high reflection coefficient, the duct termination with an annular cavity may be suggested for the suppression of noise radiation in a specific frequency band or for an effective wave reflection from the termination. PMID:11325101

  6. Sound propagation in choked ducts

    NASA Technical Reports Server (NTRS)

    Hersh, A. S.; Liu, C. Y.

    1976-01-01

    The linearized equations describing the propagation of sound in variable area ducts containing flow are shown to be singular when the duct mean flow is sonic. The singularity is removed when previously ignored nonlinear terms are retained. The results of a numerical study, for the case of plane waves propagating in a one-dimensional converging-diverging duct, show that the sound field is adequately described by the linearized equations only when the axial mean flow Mach number at the duct throat M sub th 0.6. For M sub th 0.6, the numerical results showed that acoustic energy flux was not conserved. An attempt was made to extend the study to include the nonlinear behavior of the sound field. Meaningful results were not obtained due, primarily, to numerical difficulties.

  7. Reverse Flow Engine Core Having a Ducted Fan with Integrated Secondary Flow Blades

    NASA Technical Reports Server (NTRS)

    Kisska, Michael K. (Inventor); Princen, Norman H. (Inventor); Kuehn, Mark S. (Inventor); Cosentino, Gary B. (Inventor)

    2014-01-01

    Secondary air flow is provided for a ducted fan having a reverse flow turbine engine core driving a fan blisk. The fan blisk incorporates a set of thrust fan blades extending from an outer hub and a set of integral secondary flow blades extending intermediate an inner hub and the outer hub. A nacelle provides an outer flow duct for the thrust fan blades and a secondary flow duct carries flow from the integral secondary flow blades as cooling air for components of the reverse flow turbine engine.

  8. Flow duct for nuclear reactors

    DOEpatents

    Straalsund, Jerry L.

    1978-01-01

    Improved liquid sodium flow ducts for nuclear reactors are described wherein the improvement comprises varying the wall thickness of each of the walls of a polygonal tubular duct structure so that each of the walls is of reduced cross-section along the longitudinal center line and of a greater cross-section along wall junctions with the other walls to form the polygonal tubular configuration.

  9. Guide to Air Cleaners in the Home

    MedlinePlus

    ... Air Duct Cleaning Asthma Health, Energy Efficiency and Climate Change Flood Cleanup Home Remodel Indoor airPLUS Mold Radon ... menu Learn the Issues Air Chemicals and Toxics Climate Change Emergencies Greener Living Health and Safety Land and ...

  10. Turbofan aft duct suppressor study

    NASA Technical Reports Server (NTRS)

    Syed, A. A.; Motsinger, R. E.; Fiske, G. H.; Joshi, M. C.; Kraft, R. E.

    1983-01-01

    Suppressions due to acoustic treatment in the annular exhaust duct of a model fan were theoretically predicted and compared with measured suppressions. The predictions are based on the modal analysis of sound propagation in a straight annular flow duct with segmented treatment. Modal distributions of the fan noise source (fan-stator interaction only) were measured using in-duct modal probes. The flow profiles were also measured in the vicinity of the modal probes. The acoustic impedance of the single degree of freedom treatment was measured in the presence of grazing flow. The measured values of mode distribution of the fan noise source, the flow velocity profile and the acoustic impedance of the treatment in the duct were used as input to the prediction program. The predicted suppressions, under the assumption of uniform flow in the duct, compared well with the suppressions measured in the duct for all test conditions. The interaction modes generated by the rotor-stator interaction spanned a cut-off ratio range from nearly 1 to 7.

  11. Aeroacoustic interaction in a corrugated duct

    NASA Astrophysics Data System (ADS)

    Kop'ev, V. F.; Mironov, M. A.; Solntseva, V. S.

    2008-03-01

    The sound generation by an air flow in a corrugated tube is studied experimentally for different values of the corrugation pitch and different tube lengths. The Strouhal numbers of sound generated in different tubes with different flow velocities lie within 0.4-0.6. As the flow velocity increases, the Strouhal number decreases. The effect of sound absorption by an air flow in a corrugated duct is described: in a corrugated tube with a flow, at frequencies below the generation frequency, the absorption of sound produced by an external source is observed. A semiempirical model of aeroacoustic interaction in a corrugated tube is proposed. The model provides a qualitative agreement with the experiment.

  12. Estimating evaporation duct heights from radar sea echo

    NASA Astrophysics Data System (ADS)

    Rogers, L. Ted; Hattan, Claude P.; Stapleton, Janet K.

    2000-07-01

    The evaporation duct is a downward refracting layer that results from the rapid decrease in humidity with respect to altitude occurring in the atmospheric surface layer above bodies of water. The evaporation duct affects radar detection ranges at frequencies of approximately 1 GHz and above. Models based on Monin-Obukhov similarity theory are usually used to calculate evaporation duct refractivity profiles from bulk measurements of air temperature, humidity, wind speed, and the sea surface temperature. Modeling results by Pappert et al. [1992] indicated that the falloff of radar sea echo as a function of range was an increasing function of the evaporation duct height. On the basis of those results, the authors proposed inferring the evaporation duct height by a slope fit to modeled clutter power, a nonlinear least squares inversion procedure. Data for testing the inversion procedure were obtained using the S band Space Range Radar at Wallops Island, Virginia. Evaporation duct heights were inferred from the radar data on the basis of the assumption of a range-independent evaporation duct height and sea clutter radar cross section (σ°). Validation data consist of buoy and boat in situ bulk measurements. The result of comparing the radar-inferred evaporation duct heights and those calculated from bulk measurements indicates that the radar-inferred duct heights are strongly correlated with those from the in situ measurements, but there is some uncertainty as to whether they are biased or unbiased. That uncertainty arises from the assumed dependence of σ° on the grazing angle ψ. That dependence is currently a matter of debate in the open literature, with the lower and upper ends of modeling results being σ° ∝ ψ0; and σ° ∝ ψ4, respectively. We show results for both dependencies and note that the σ° ∝ ψ0; provides the best agreement with our measurements. It should be noted that inferring the evaporation duct height from radar sea echo is a problem

  13. CASE STUDY OF DUCT RETROFIT OF A 1985 HOME AND GUIDELINES FOR ATTIC AND CRAWL SPACE DUCT SEALING

    SciTech Connect

    Boudreaux, Philip R; Christian, Jeffrey E; Jackson, Roderick K

    2012-01-01

    The U.S. Department of Energy (DOE) is fully committed to research for developing the information and capabilities necessary to provide cost-effective residential retrofits yielding 50% energy savings within the next several years. Heating, ventilation, and air conditioning (HVAC) is the biggest energy end use in the residential sector, and a significant amount of energy can be wasted through leaky ductwork in unconditioned spaces such as attics and crawl spaces. A detailed duct sealing case study is presented for one house along with nine brief descriptions of other duct retrofits completed in the mixed-humid climate. Costs and estimated energy savings are reported for most of the ten houses. Costs for the retrofits ranged from $0.92/ft2 to $1.80/ft2 of living space and estimated yearly energy cost savings due to the duct retrofits range from 1.8% to 18.5%. Lessons learned and duct sealing guidelines based on these ten houses, as well as close work with the HVAC industry in the mixed-humid climate of East Tennessee, northern Georgia, and south-central Kentucky are presented. It is hoped that the lessons learned and guidelines will influence local HVAC contractors, energy auditors, and homeowners when diagnosing or repairing HVAC duct leakage and will be useful for steering DOE s future research in this area.

  14. Air Distribution Retrofit Strategies for Affordable Housing

    SciTech Connect

    Dentz, J.; Conlin, F.; Holloway, P.; Podorson, D.; Varshney, K.

    2014-03-01

    In multifamily and attached buildings, traditional duct sealing methods are often impractical or costly and disruptive because of the difficulty in accessing leakage sites. In this project, two retrofit duct sealing techniques -- manually-applied sealants and injecting a spray sealant, were implemented in several low-rise multi-unit buildings. An analysis on the cost and performance of the two methods are presented. Each method was used in twenty housing units: approximately half of each group of units are single story and the remainder two-story. Results show that duct leakage to the outside was reduced by an average of 59% through the use of manual methods, and by 90% in the units where the injected spray sealant was used. It was found that 73% of the leakage reduction in homes that were treated with injected spray sealant was attributable to the manual sealing done at boots, returns and the air handler. The cost of manually-applying sealant ranged from $275 to $511 per unit and for the injected spray sealant the cost was $700 per unit. Modeling suggests a simple payback of 2.2 years for manual sealing and 4.7 years for the injected spray sealant system. Utility bills were collected for one year before and after the retrofits. Utility bill analysis shows 14% and 16% energy savings using injected spray sealant system and hand sealing procedure respectively in heating season whereas in cooling season, energy savings using injected spray sealant system and hand sealing were both 16%.

  15. Air Distribution Retrofit Strategies for Affordable Housing

    SciTech Connect

    Dentz, J.; Conlin, F.; Holloway, Parker; Podorson, David; Varshney, Kapil

    2014-03-01

    In multifamily and attached buildings, traditional duct sealing methods are often impractical or costly and disruptive because of the difficulty in accessing leakage sites. In this project, two retrofit duct sealing techniques, manually-applied sealants and injecting a spray sealant, were implemented in several low-rise multiunit buildings. An analysis on the cost and performance of the two methods are presented. Each method was used in twenty housing units: approximately half of each group of units are single story and the remainder are two story. Results show that duct leakage to the outside was reduced by an average of 59% through the use of manual methods, and by 90% in the units where the injected spray sealant was used. It was found that 73% of the leakage reduction in homes that were treated with injected spray sealant was attributable to the manual sealing done at boots, returns and the air handler. The cost of manually-applying sealant ranged from $275 to $511 per unit and for the injected spray sealant the cost was $700 per unit. Modeling suggests a simple payback of 2.2 years for manual sealing and 4.7 years for the injected spray sealant system. Utility bills were collected for one year before and after the retrofits. Utility bill analysis shows 14% and 16% energy savings using injected spray sealant system and hand sealing procedure respectively in heating season whereas in cooling season, energy savings using injected spray sealant system and hand sealing were both 16%.

  16. Evaporation duct refractivity profile from satellite meteorological data

    NASA Astrophysics Data System (ADS)

    Levadnyi, Iu.; Ivanov, V.; Shalyapin, V.

    The refractivity profile is initial data for the microwave propagation prediction models Evaporation duct height is usually used to characterize refractivity profile in the surface layer over sea The evaporation duct height is calculated using bulk measurement of air temperature wind speed humidity pressure at some level and sea surface temperature Four prevailing models LKB Liu-Katsaros-Businger RSHMU Russian State Hydro-Meteorological University optimized by us ECMWF European Center for Medium range Weather Forecast and COARE Coupled Ocean-Atmosphere Response Experiment were examined The results of computation using above mentioned models were compared with the direct refractometric measurements All measurements meteorological and refractometric were made by us during two marine expeditions First expedition was in the Atlantic ocean from March to May in latitude 22 circ-32° North and longitude 52 circ-65° West 29 measurements Second one was in the Indian ocean from December to February in latitude 0 circ-15° North and longitude 55 circ-80° East 94 measurements The approximation by least square-root method was carried out to compare the direct measurements of evaporation duct height with the results of computations The minimum square-root error is obtained for LKB model 2 59m for negative air-sea temperature difference 2 42m maximum - for ECMWF model 2 72m All models overestimate low evaporation duct heights and underestimate - high values This effect is least of all define in RSHMU

  17. Technology Solutions Case Study: Duct in Conditioned Space in a Dropped Ceiling or Fur-down, Gainesville, Florida

    SciTech Connect

    2014-09-01

    Forced-air distribution systems (duct systems) typically are installed out of sight for aesthetic reasons, most often in unconditioned areas such as attics or crawlspaces. Any leakage of air to or from the duct system in unconditioned space not only loses energy, but impacts home and equipment durability and indoor air quality. An obvious solution is to bring the duct system into the interior of the house, either by sealing the area where the ducts are installed (attic or crawlspace) or by building an interior cavity or chase above the ceiling plane (raised ceiling or fur-up chase) or below the ceiling plane (dropped ceiling or fur-down) for the duct system. In this project, Building America Partnership for Improved Residential Construction team partnered with Tommy Williams Homes to implement an inexpensive, quick, and effective method of building a fur-down chase.

  18. Evaporation duct communication: Test Plan

    NASA Astrophysics Data System (ADS)

    Anderson, K. D.

    1991-02-01

    The Evaporation Duct Communication (EDCOM) project is an effort to provide an alternative ship-to-ship communications channel using the natural environment. A microwave communication link can be used on an over-the-water, over-the-horizon path through the evaporation duct. This report shows how a microwave communication link, operating at a range separation of more than twice the line-of-sight range, can be constructed. This link can achieve about 80-percent availability at a transmission frequency of 14.5 GHz and can be constructed using off-the-shelf RF equipment. Operation of this link will provide the first set of measurements of channel capacity that can be critically dependent on the existence of an oceanic evaporation duct. Construction of this link presents a unique opportunity to study and evaluate an alternative communications channel that can be used to alleviate naval battlegroup communications load.

  19. Congenital Atresia of Wharton's Duct.

    PubMed

    Hseu, Anne; Anne, Premchand; Anne, Samantha

    2016-02-01

    This is a case report of a three-month-old male who presented to clinic with a cystic lesion under the tongue. On clinical examination, a cystic lesion was observed in the, floor-of-mouth. The patient was referred to Paediatric Otorhinolaryngology service for further management. The differential diagnoses for floor-of-mouth lesions should be reviewed with primary focus on the Wharton's duct atresia and its management. It is crucial to recognize submandibular duct atresia in the primary Paediatric clinic in order to expedite management of lesion before complications arise including infection, enlargement of cyst, and feeding and breathing difficulties. PMID:27042492

  20. General Information about Extrahepatic Bile Duct Cancer

    MedlinePlus

    ... Bile Duct Cancer Treatment (PDQ®)–Patient Version General Information About Bile Duct Cancer Go to Health Professional ... the PDQ Adult Treatment Editorial Board . Clinical Trial Information A clinical trial is a study to answer ...

  1. What Are the Key Statistics about Bile Duct Cancer?

    MedlinePlus

    ... for bile duct cancer? What are the key statistics about bile duct cancer? Bile duct cancer is ... it is when it is found. For survival statistics, see the section “ Survival statistics for bile duct ...

  2. Viscous flow computations for elliptical two-duct version of the SSME hot gas manifold

    NASA Technical Reports Server (NTRS)

    Roger, R. P.

    1986-01-01

    The objective of the effort was to numerically simulate viscous subsonic flow in a proposed elliptical two-duct version of the fuel side Hot Gas Manifold (HGM) for the Space Shuttle Main Engine (SSME). The numerical results were to complement both water flow and air flow experiments in the two-duct geometry performed at NASA-MSFC and Rocketdyne. The three-dimensional character of the HGM consists of two essentially different geometries. The first part of the construction is a concentric shell duct structure which channels the gases from a turbine exit into the second part comprised of two cylindrically shaped transfer ducts. The initial concentric shell portion can be further subdivided into a turnaround section and a bowl section. The turnaround duct (TAD) changes the direction of the mean flow by 180 degress from a smaller radius to a larger radius duct which discharges into the bowl. The cylindrical transfer ducts are attached to the bowl on one side thus providing a plane of symmetry midway between the two. Centerline flow distance from the TAD inlet to the transfer duct exit is approximately two feet. Details of the approach used to numerically simulate laminar or turbulent flow in the HGM geometry are presented. Computational results are presented and discussed.

  3. Moulded calculus of common bile duct mimicking a stenosis

    PubMed Central

    Brocki, Marian; Śmigielski, Jacek

    2014-01-01

    Bile duct stenosis, in most cases, appears to be the consequence of pancreatic head, ampulla of Vater and bile duct tumours, cholangitis sclerosans, as well as iatrogenic damages, which may all be diagnosed during endoscopic retrograde cholangiopancreatography (ERCP). In very rare cases the restriction may result from an atypically shaped wedged stone. This situation creates many diagnostic problems, which in the majority of cases can be solved using imaging studies. However, in some patients even a significant extension of diagnostic procedures may not lead to a correct diagnosis. We present a diagnostically difficult case of a deposit imitating restriction. We present a 70-year-old woman with common bile duct restriction undiagnosed despite several ultrasound examinations (USG), computed tomography (CT), double magnetic resonance cholangiopancreatography (MRCP) and endoscopic retrograde cholangiopancreatography (ERCP). Only after the third ERCP examination a fragmented, by formerly introduced prosthesis, deposit, imitating narrowing, was revealed. Identification of bile duct deposits depends on their composition, localisation and the imaging techniques used. Pigment calculi with atypical shape, bile density, air density or surrounding tissue density are very difficult to diagnose. Thus, the sensitivity of common bile duct stone detection in USG, CT, MRCP and endoscopic ultrasound (EUS) is 5–88%; 6–88%; 73–97%; and 84–98%, respectively. Moreover, ERCP may not diagnose the character of the restriction even in 5.2% up to 30% of the patients. Consequently, assessment of diagnosis in a number of patients is difficult. A deposit imitating common bile duct (CBD) restriction is a rare, difficult to diagnose phenomenon, which should be taken into account during differential diagnosis of CBD restrictions. PMID:25061493

  4. Wind Turbine With Concentric Ducts

    NASA Technical Reports Server (NTRS)

    Muhonen, A. J.

    1983-01-01

    Wind Turbine device is relatively compact and efficient. Converging inner and outer ducts increase pressure difference across blades of wind turbine. Turbine shaft drives alternator housed inside exit cone. Suitable for installation on such existing structures as water towers, barns, houses, and commercial buildings.

  5. Vitellointestinal Duct Anomalies in Infancy

    PubMed Central

    Kadian, Yogender Singh; Verma, Anjali; Rattan, Kamal Nain; Kajal, Pardeep

    2016-01-01

    Background: Vitellointestinal duct (VID) or omphalomesenteric duct anomalies are secondary to the persistence of the embryonic vitelline duct, which normally obliterates by weeks 5–9 of intrauterine life. Methods: This is a retrospective analysis of a total of 16 patients of symptomatic remnants of vitellointestinal duct from period of Jan 2009 to May 2013. Results: Male to female ratio (M:F) was 4.3:1 and mean age of presentation was 2 months and their mode of presentation was: patent VID in 9 (56.25%) patients, umbilical cyst in 2(12.25%), umbilical granuloma in 2 (12.25%), and Meckel diverticulum as content of hernia sac in obstructed umbilical hernia in 1 (6.25%) patient. Two patients with umbilical fistula had severe electrolyte disturbance and died without surgical intervention. Conclusion: Persistent VID may have varied presentations in infancy. High output umbilical fistula and excessive bowel prolapse demand urgent surgical intervention to avoid morbidity and mortality. PMID:27433448

  6. Design and performance of duct acoustic treatment

    NASA Technical Reports Server (NTRS)

    Motsinger, R. E.; Kraft, R. E.

    1991-01-01

    The procedure for designing acoustic treatment panels used to line the walls of aircraft engine ducts and for estimating the resulting suppression of turbofan engine duct noise is discussed. This procedure is intended to be used for estimating noise suppression of existing designs or for designing new acoustic treatment panels and duct configurations to achieve desired suppression levels.

  7. 46 CFR 116.610 - Ventilation ducts.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... requirements relative to the passage of smoke and flame as the fire control boundary penetrated; (2) A steel duct penetrating an A-Class fire control boundary must be of at least 11 USSG, and a steel duct... duct penetrating an A-Class fire control boundary and opening into a space formed by that boundary...

  8. 46 CFR 116.610 - Ventilation ducts.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... requirements relative to the passage of smoke and flame as the fire control boundary penetrated; (2) A steel duct penetrating an A-Class fire control boundary must be of at least 11 USSG, and a steel duct... duct penetrating an A-Class fire control boundary and opening into a space formed by that boundary...

  9. 30 CFR 57.22215 - Separation of intake and return air (I-A, II-A, III, and V-A mines).

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... openings to the surface— (1) Ventilation tubing approved by MSHA in accordance with 30 CFR part 7 or... for separation of air currents. Such wall or partition shall be constructed of reinforced concrete...

  10. 30 CFR 57.22215 - Separation of intake and return air (I-A, II-A, III, and V-A mines).

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... openings to the surface— (1) Ventilation tubing approved by MSHA in accordance with 30 CFR part 7 or... for separation of air currents. Such wall or partition shall be constructed of reinforced concrete...

  11. 30 CFR 57.22215 - Separation of intake and return air (I-A, II-A, III, and V-A mines).

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... openings to the surface— (1) Ventilation tubing approved by MSHA in accordance with 30 CFR part 7 or... separation of main air currents in the same opening. Flexible ventilation tubing shall not exceed 250 feet...

  12. 30 CFR 57.22215 - Separation of intake and return air (I-A, II-A, III, and V-A mines).

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... openings to the surface— (1) Ventilation tubing approved by MSHA in accordance with 30 CFR part 7 or... separation of main air currents in the same opening. Flexible ventilation tubing shall not exceed 250 feet...

  13. 30 CFR 57.22215 - Separation of intake and return air (I-A, II-A, III, and V-A mines).

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... openings to the surface— (1) Ventilation tubing approved by MSHA in accordance with 30 CFR part 7 or... for separation of air currents. Such wall or partition shall be constructed of reinforced concrete...

  14. Improved Duct Systems Task Report with StageGate 2 Analysis

    SciTech Connect

    Moyer, Neil; Stroer, Dennis

    2007-12-31

    This report is about Building America Industrialized Housing Partnership's work with two industry partners, Davalier Homes and Southern Energy Homes, in constructing and evaluating prototype interior duct systems. Issues of energy performance, comfort, DAPIA approval, manufacturability and cost is addressed. A stage gate 2 analysis addresses the current status of project showing that there are still refinements needed to the process of incorporating all of the ducts within the air and thermal boundaries of the envelope.

  15. Pressure losses across multiple fittings in ventilation ducts.

    PubMed

    Ai, Z T; Mak, C M

    2013-01-01

    The accurate prediction of pressure losses across in-duct fittings is of significance in relation to the accurate sizing and good energy efficiency of air-delivery systems. Current design guides provide design methods and data for the prediction of pressure losses only for a single and isolated fitting. This study presents an investigation of pressure losses across multiple interactive in-duct fittings in a ventilation duct. A laboratory measurement of pressure losses across one fitting and multiple fittings in a ventilation duct is carried out. The pressure loss across multiple interactive fittings is lower than that across multiple similar individual fittings, while the percentage decrease is dependent on the configuration and combination of the fittings. This implies that the pressure loss across multiple closely mounted fittings calculated by summing the pressure losses across individual fittings, as provided in the ASHRAE handbook and the CIBSE guide, is overpredicted. The numerical prediction of the pressure losses across multiple fittings using the large-eddy simulation (LES) model shows good agreement with the measured data, suggesting that this model is a useful tool in ductwork design and can help to save experimental resources and improve experimental accuracy and reliability. PMID:24385871

  16. Pressure Losses across Multiple Fittings in Ventilation Ducts

    PubMed Central

    Ai, Z. T.; Mak, C. M.

    2013-01-01

    The accurate prediction of pressure losses across in-duct fittings is of significance in relation to the accurate sizing and good energy efficiency of air-delivery systems. Current design guides provide design methods and data for the prediction of pressure losses only for a single and isolated fitting. This study presents an investigation of pressure losses across multiple interactive in-duct fittings in a ventilation duct. A laboratory measurement of pressure losses across one fitting and multiple fittings in a ventilation duct is carried out. The pressure loss across multiple interactive fittings is lower than that across multiple similar individual fittings, while the percentage decrease is dependent on the configuration and combination of the fittings. This implies that the pressure loss across multiple closely mounted fittings calculated by summing the pressure losses across individual fittings, as provided in the ASHRAE handbook and the CIBSE guide, is overpredicted. The numerical prediction of the pressure losses across multiple fittings using the large-eddy simulation (LES) model shows good agreement with the measured data, suggesting that this model is a useful tool in ductwork design and can help to save experimental resources and improve experimental accuracy and reliability. PMID:24385871

  17. 21. STATION 70.5 OF MST, WEST SIDE. AIRCONDITIONING DUCT AT ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    21. STATION 70.5 OF MST, WEST SIDE. AIR-CONDITIONING DUCT AT TOP; POWER BOX ON RIGHT; WINCH ON LEFT. - Vandenberg Air Force Base, Space Launch Complex 3, Launch Pad 3 East, Napa & Alden Roads, Lompoc, Santa Barbara County, CA

  18. Designing insulation for cryogenic ducts

    NASA Astrophysics Data System (ADS)

    Love, C. C.

    1984-03-01

    It is pointed out that the great temperature difference between the outside of a cryogenic duct and the liquified gas it carries can cause a high heat input unless blocked by a high thermal resistance. High thermal resistance for lines needing maximum insulation is provided by metal vacuum jackets. Low-density foam is satisfactory in cases in which higher heat input can be tolerated. Attention is given to the heat transfer through a duct vacuum jacket, the calculation of heat input and the exterior surface's steady-state temperature for various thicknesses of insulation, the calculation of the heat transfer through gimbal jackets, and design specifications regarding the allowable pressure rise in the jacket's annular space.

  19. Tear-ducts in wine

    NASA Astrophysics Data System (ADS)

    Bush, John W. M.

    1999-11-01

    We examine the radial spoke pattern evident in the meniscus region in glasses of strong alcoholic beverages exhibiting the `tears-in-wine' phenomenon. We demonstrate that the pattern results from ridge-like elevations of the free surface which are supported by evaporatively-driven Marangoni convection in the meniscus region. Vortices associated with the convective motions are aligned in the radial direction by the surface tension gradient responsible for the generation of tears. The radial flow is focussed into the ridges, which thus serve as the principal conduits of fluid for the tears; consequently, we refer to the ridges as `tear-ducts'. The phenomenon is examined experimentally, and a numerical model of evaporatively-driven Marangoni convection is developed which reproduces the salient features of the tear-duct phenomenon.

  20. HAARP-Induced Ionospheric Ducts

    SciTech Connect

    Milikh, Gennady; Vartanyan, Aram

    2011-01-04

    It is well known that strong electron heating by a powerful HF-facility can lead to the formation of electron and ion density perturbations that stretch along the magnetic field line. Those density perturbations can serve as ducts for ELF waves, both of natural and artificial origin. This paper presents observations of the plasma density perturbations caused by the HF-heating of the ionosphere by the HAARP facility. The low orbit satellite DEMETER was used as a diagnostic tool to measure the electron and ion temperature and density along the satellite orbit overflying close to the magnetic zenith of the HF-heater. Those observations will be then checked against the theoretical model of duct formation due to HF-heating of the ionosphere. The model is based on the modified SAMI2 code, and is validated by comparison with well documented experiments.

  1. STS 127 Return Samples: Assessment of Air Quality aboard the Shuttle (STS-127) and International Space Station (2J/A)

    NASA Technical Reports Server (NTRS)

    James, John T.

    2010-01-01

    The toxicological assessments of 2 grab sample canisters (GSCs) from the Shuttle are reported. The toxicological assessment of 9 GSCs and 6 pairs of formaldehyde badges from the ISS is also reported. Other than a problem with traces of acrolein in the samples, the air quality was acceptable for respiration.

  2. Small duct primary sclerosing cholangitis without inflammatory bowel disease is genetically different from large duct disease

    PubMed Central

    Næss, Sigrid; Björnsson, Einar; Anmarkrud, Jarl A.; Al Mamari, Said; Juran, Brian D.; Lazaridis, Konstantinos N.; Chapman, Roger; Bergquist, Annika; Melum, Espen; Marsh, Steven G. E.; Schrumpf, Erik; Lie, Benedicte A.; Boberg, Kirsten Muri; Karlsen, Tom H.; Hov, Johannes R.

    2014-01-01

    Background & aims Small duct primary sclerosing cholangitis (PSC) is phenotypically a mild version of large duct PSC, but it is unknown whether these phenotypes share aetiology. We aimed to characterize their relationship by investigating genetic associations in the HLA complex, which represent the strongest genetic risk factors in large duct PSC. Methods Four classical HLA loci (HLA-A, HLA-B, HLA-C, HLA-DRB1) were genotyped in 87 small duct PSC patients, 485 large duct PSC patients and 1117 controls across three geographical regions. Results HLA-DRB1*13:01 (OR=2.0, 95% CI 1.2–3.4, P=0.01) and HLA-B*08 (OR=1.6, 95% CI 1.1–2.4, P=0.02) were significantly associated with small duct PSC compared with healthy controls. Based on the observed frequency of HLA-B*08 in small duct PSC, the strongest risk factor in large duct PSC, an estimated 32% (95% CI 4%–65%) of this population can be hypothesized to represent early stages or mild variants of large duct PSC. This subgroup may be constituted by small duct PSC patients with inflammatory bowel disease (IBD), which greatly resembled large duct PSC in its HLA association. In contrast, small duct PSC without IBD was only associated with HLA-DRB1*13:01(P=0.03) and was otherwise distinctly dissimilar from large duct PSC. Conclusions Small duct PSC with IBD resembles large duct PSC in its HLA association and may represent early stages or mild variants of large duct disease. Different HLA associations in small duct PSC without IBD could indicate that this subgroup is a different entity. HLA-DRB1*13:01 may represent a specific risk factor for inflammatory bile duct disease. PMID:24517468

  3. Laser Microdissection of the Alveolar Duct Enables Single-Cell Genomic Analysis

    PubMed Central

    Bennett, Robert D.; Ysasi, Alexandra B.; Belle, Janeil M.; Wagner, Willi L.; Konerding, Moritz A.; Blainey, Paul C.; Pyne, Saumyadipta; Mentzer, Steven J.

    2014-01-01

    Complex tissues such as the lung are composed of structural hierarchies such as alveoli, alveolar ducts, and lobules. Some structural units, such as the alveolar duct, appear to participate in tissue repair as well as the development of bronchioalveolar carcinoma. Here, we demonstrate an approach to conduct laser microdissection of the lung alveolar duct for single-cell PCR analysis. Our approach involved three steps. (1) The initial preparation used mechanical sectioning of the lung tissue with sufficient thickness to encompass the structure of interest. In the case of the alveolar duct, the precision-cut lung slices were 200 μm thick; the slices were processed using near-physiologic conditions to preserve the state of viable cells. (2) The lung slices were examined by transmission light microscopy to target the alveolar duct. The air-filled lung was sufficiently accessible by light microscopy that counterstains or fluorescent labels were unnecessary to identify the alveolar duct. (3) The enzymatic and microfluidic isolation of single cells allowed for the harvest of as few as several thousand cells for PCR analysis. Microfluidics based arrays were used to measure the expression of selected marker genes in individual cells to characterize different cell populations. Preliminary work suggests the unique value of this approach to understand the intra- and intercellular interactions within the regenerating alveolar duct. PMID:25309876

  4. Studies in short haul air transportation in the California corridor: Effects of design runway length; community acceptance; impact of return on investment and fuel cost increases, volume 1

    NASA Technical Reports Server (NTRS)

    Shevell, R. S.; Jones, D. W., Jr.

    1973-01-01

    The impact of design runway length on the economics and traffic demand of a 1985 short haul air transportation system in the California Corridor was investigated. The community acceptance of new commercial airports for short haul service was studied. The following subjects were analyzed: (1) travel demand, (2) vehicle technology, (3) infrastructure, (4) systems analysis, and (5) effects on the community. The operation of the short haul system is compared with conventional airline operations.

  5. Measure Guideline: Optimizing the Configuration of Flexible Duct Junction Boxes

    SciTech Connect

    Beach, R.; Burdick, A.

    2014-03-01

    This measure guideline offers additional recommendations to heating, ventilation, and air conditioning (HVAC) system designers for optimizing flexible duct, constant-volume HVAC systems using junction boxes within Air Conditioning Contractors of America (ACCA) Manual D guidance. IBACOS used computational fluid dynamics software to explore and develop guidance to better control the airflow effects of factors that may impact pressure losses within junction boxes among various design configurations. These recommendations can help to ensure that a system aligns more closely with the design and the occupants' comfort expectations. Specifically, the recommendations described herein show how to configure a rectangular box with four outlets, a triangular box with three outlets, metal wyes with two outlets, and multiple configurations for more than four outlets. Designers of HVAC systems, contractors who are fabricating junction boxes on site, and anyone using the ACCA Manual D process for sizing duct runs will find this measure guideline invaluable for more accurately minimizing pressure losses when using junction boxes with flexible ducts.

  6. Refraction of acoustic duct waveguide modes by exhaust jets.

    NASA Technical Reports Server (NTRS)

    Mani, R.

    1973-01-01

    The refraction of acoustic duct waveguide modes emitted from the open end of a semiinfinite rectangular duct by a jet-like exhaust flow is studied theoretically. The problem is formulated as a Wiener-Hopf problem and is ultimately solved by an approximate method due to Carrier and Koiter. Continuity of transverse acoustic particle displacement and of acoustic pressure is assumed at the jet/still-air interface. The solution exhibits several features of the acoustics of moving media such as a source convection effect, zones of relative silence, and simple refraction. Plots of far-field directivity patterns are presented for several cases and show refraction effects to be important even at modest exhaust Mach numbers of order 0.3. Only subsonic exhaust Mach numbers are considered.

  7. Duct wall impedance control as an advanced concept for acoustic impression

    NASA Technical Reports Server (NTRS)

    Dean, P. D.; Tester, B. J.

    1975-01-01

    Models and tests on an acoustic duct liner system which has the property of controlled-variable acoustic impedance are described. This is achieved by a novel concept which uses the effect of steady air flow through a multi-layer, locally reacting, resonant-cavity absorber. The scope of this work was limited to a 'proof of concept.' The test of the concept was implemented by means of a small-scale, square-section flow duct facility designed specifically for acoustic measurements, with one side of the duct acoustically lined. The test liners were designed with the aid of previously established duct acoustic theory and a semi-empirical impedance model of the liner system. Over the limited range tested, the liner behaved primarily as predicted, exhibiting significant changes in resistance and reactance, thus providing the necessary concept validation.

  8. Parotid salivary duct stenosis following caudal maxillectomy.

    PubMed

    Mestrinho, Lisa A; Faísca, Pedro B; Niza, Maria M R E

    2014-01-01

    Parotid salivary duct dilation was diagnosed in a 9-year-old male dog. The dog had undergone caudal maxillectomy on the ipsilateral side 2-years prior to presentation. Treatment consisted of parotid salivary duct excision and superficial parotidectomy that lead to the resolution of clinical signs. Transient facial neuropraxia was observed immediately after surgery and resolved spontaneously after 2-weeks. Parotid salivary duct dilation should be considered as a chronic postoperative complication following caudal maxillectomy. PMID:24902412

  9. Lightweight Forms for Epoxy/Aramid Ducts

    NASA Technical Reports Server (NTRS)

    Mix, E. W.; Anderson, A. N.; Bedford, Donald L., Sr.

    1986-01-01

    Aluminum mandrels easy to remove. Lightweight aluminum mandrel for shaping epoxy/aramid ducts simplifies and speeds production. In new process, glass-reinforced epoxy/aramid cloth wrapped on aluminum mandrel. Stainless-steel flanges and other hardware fitted on duct and held by simple tooling. Entire assembly placed in oven to cure epoxy. After curing, assembly placed in alkaline bath dissolves aluminum mandrel in about 4 hours. Epoxy/aramid shell ready for use as duct. Aluminum mandrel used to make ducts of various inside diameters up to 6 in. Standard aluminum forms used. Conventional tube-bending equipment produces requisite curves in mandrels.

  10. Traumatic injury of the thoracic duct.

    PubMed

    Guzman, A E; Rossi, L; Witte, C L; Smyth, S

    2002-03-01

    Injuries to the thoracic duct are infrequent but may become life-threatening when chylous leakage persists. This report describes 6 patients with such injuries in whom the leakage resolved spontaneously in one, was corrected using microsurgical lymphatic repair or lymphatic-venous anastomosis in two, successfully treated either by ligation of the thoracic duct or insertion of a peritoneovenous shunt in two, and was eventually controlled after bilateral pleurodesis and thoracic duct ligation by insertion of a peritoneo-venous shunt in one. Conventional lymphography is superior to lymphoscintigraphy and is usually required to document disruption of the thoracic duct. PMID:11939572

  11. Generator stator core vent duct spacer posts

    DOEpatents

    Griffith, John Wesley; Tong, Wei

    2003-06-24

    Generator stator cores are constructed by stacking many layers of magnetic laminations. Ventilation ducts may be inserted between these layers by inserting spacers into the core stack. The ventilation ducts allow for the passage of cooling gas through the core during operation. The spacers or spacer posts are positioned between groups of the magnetic laminations to define the ventilation ducts. The spacer posts are secured with longitudinal axes thereof substantially parallel to the core axis. With this structure, core tightness can be assured while maximizing ventilation duct cross section for gas flow and minimizing magnetic loss in the spacers.

  12. Extent of fungal growth on fiberglass duct liners with and without biocides under challenging environmental conditions.

    PubMed

    Samimi, Behzad S; Ross, Kristen

    2003-03-01

    Eight brands of fiberglass duct liners, including three that contained biocides, were exposed to challenging environmental conditions that would promote fungal growth. Twenty-four rectangular sheet metal ducts in three groups of eight ducts per group were lined with the eight selected liners. Each group of ducts was exposed to one of the three test conditions within an environmental chamber for a period of 15 days. These conditions were a) 75 percent RH, b) 75 percent RH plus water spray, c) 75 percent RH plus dry nutrient, and d) 75 percent RH plus water plus nutrient. Viable spores of Aspergillus niger were aerosolized into each duct as seed. On the 16th day, air and surface samples for fungal spores were collected from inside ducts. The results of air sampling using N6 sampler and visual inspection indicated that two out of three biocide-containing liners, Permacote and Toughgard, inhibited fungal growth but only under condition A. The third biocide-containing liner, Aeroflex Plus, was effective even when it was wet (conditions A and B). All three biocide-containing liners failed to inhibit fungal growth under conditions C and D. Among the five other types of liners that did not contain biocides, ATCO Flex with a smooth Mylar coating was more preferable, exhibiting lower fungal activity during conditions A, B, and C. All liners failed under condition D when nutrient and water were added together. Surface sampling using adhesive tape failed to produce representative results, apparently due to rough/porous surface of duct liners. It was concluded that duct liners with biocide treatment could be less promoting to microbial growth under high humidity as long as their surfaces remain clean and water-free. A liner with an impermeable and smooth surface seems to be less subject to microbial growth under most conditions than biocide-containing liners having porous and/or rough surfaces. PMID:12573965

  13. Wastefree in-duct FGD

    SciTech Connect

    Nelson, S. Jr.

    1995-12-31

    The first generation of easily-retrofitable duct-injection technologies experienced problems with modest performance, particulate non-compliance, and difficult waste disposal. A new sorbent concept, called Fluesorbent, has been developed specifically to address these problems. Based on a new lime sorbent material, the technology results in 80+% SO{sub 2} removal, net particulate reductions, and a valuable agricultural by-product instead of wastes. A 6,500 acfm, 2-MWe Fluesorbent pilot plant was recently constructed at Ohio Edison`s R.E. Burger station. This paper describes the technology and the Burger demonstration project.

  14. Numerical characterization of the hydrodynamics and thermal behavior of air flow in flexible air distribution system

    NASA Astrophysics Data System (ADS)

    Gharehdaghi, Samad; Moujaes, Samir

    2013-10-01

    Flexible duct air distribution systems are used in a large percentage of residential and small commercial buildings in the United States . Very few empirical or predictive data are available though to help provide the HVAC design engineer with reliable information . Moreover, because of the ducts flexibility, the shapes of these ducts offer a different set of operating fluid flow and thermal conditions from traditional smooth metal ducts. Hence, both the flow field and heat transfer through this kind of ducts are much more complex and merit to be analyzed from a numerical predictive approach. The aim of this research paper is to compute some of the hydrodynamic and heat transfer characteristics of the air flow inside these ducts over a range of Re numbers commonly used in the flow conditions of these air distribution systems. The information resulting from this CFD simulation, where a κ-ɛ turbulent model is used to predict the flow conditions, provide pressure drop and average convective heat transfer coefficients that exist in these ducts and was compared to previously found data. Circulation zones in the depressions of these ducts are found to exist which are suspected of influencing the pressured drop and heat transfer coefficients as compared to smooth ducts. The results show that fully developed conditions exist much earlier with regard to the inlet for both hydrodynamic and thermal entrance regions than what would be expected in smooth ducts under the same turbulent conditions.

  15. Optimization of the mechanical performance of a two-duct semicircular duct system--part 1: dynamics and duct dimensions.

    PubMed

    Muller, M; Verhagen, J H G

    2002-06-21

    The classical representation of the semicircular duct system consists of three separate duct circuits. The ducts are, however, in reality, hydrodynamically interconnected. Muller & Verhagen (1988a,b) derived equations for the mechanical behaviour of an interconnected system with three ducts (anterior, posterior and horizontal). An analytical solution of these equations would, however, be too complex to provide surveyable formulae. A system of two interconnected ducts avoids this complexity whilst keeping the essentials of the coupling of ducts intact. The solution of the equation of motion leads to expressions for time constants and maximal endolymph excursions which are functions of morphological parameters, viz. the ratios of radii (gamma) and lengths (lambda) of the common vestibular part (crus commune or utriculus) and the ducts. The system possesses two short time constants which are shown to have similar values. The maximum endolymph displacements in the two ducts after a steplike stimulus are the products of the respective initial velocities and combinations of time constants. The initial velocities depend strongly on the position of the labyrinth with respect to the excitating rotation vector. Measured data of gamma and lambda are compared with the theoretical results. For gamma, excellent agreement was found. lambda is treated elsewhere. PMID:12151258

  16. Vanishing bile duct syndrome in the context of concurrent temozolomide for glioblastoma.

    PubMed

    Mason, Matthew; Adeyi, Oyedele; Fung, Scott; Millar, Barbara-Ann

    2014-01-01

    Temozolomide, an oral alkylating agent, is used in the treatment of glioblastoma. We describe a case of a 62-year-old woman developing jaundice with significant derangement of liver function tests on day 17 of focal radiotherapy with concomitant temozolomide. There was no structural abnormality on imaging and liver biopsy was performed. Pathology revealed absence of small terminal bile ducts affecting up to 60% of sampled portal tracts and senescence of many of the remaining small bile ducts, in keeping with a diagnosis of acute vanishing bile duct syndrome. This is a rare syndrome. It has been documented in association with Hodgkin's lymphoma and viral causes. Drugs implicated as precipitating this condition include antiseizure medications, some antibiotics, ibuprofen and antifungals. Temozolomide was stopped. The patient received supportive care, ursodeoxycholic acid 750 mg daily and cholestyramine 4 g twice daily. She was otherwise asymptomatic and her blood results returned to normal by day 129. PMID:25432915

  17. Measure Guideline: Sealing and Insulating of Ducts in Existing Homes

    SciTech Connect

    Aldrich, R.; Puttagunta, S.

    2011-12-01

    This document begins with a discussion on potential cost and performance benefits of duct sealing and insulating. It continues with a review of typical duct materials and components and the overall procedures for assessing and improving the duct system.

  18. What's New in Bile Duct Cancer Research and Treatment?

    MedlinePlus

    ... Topic Additional resources for bile duct cancer What’s new in bile duct cancer research and treatment? Bile ... is tumor blood vessels. Bile duct tumors need new blood vessels to grow beyond a certain size. ...

  19. Measure Guideline. Sealing and Insulating Ducts in Existing Homes

    SciTech Connect

    Aldrich, R.; Puttagunta, S.

    2011-12-01

    This document begins with a discussion on potential cost and performance benefits of duct sealing and insulating. It continues with a review of typical duct materials and components and the overall procedures for assessing and improving the duct system.

  20. Do We Know What Causes Bile Duct Cancer?

    MedlinePlus

    ... duct cancer be prevented? Do we know what causes bile duct cancer? We don’t know the exact cause of ... to top » Guide Topics What Is Bile Duct Cancer? Causes, Risk Factors, and Prevention Early Detection, Diagnosis, and ...

  1. Navier-Stokes analysis and experimental data comparison of compressible flow within ducts

    NASA Technical Reports Server (NTRS)

    Harloff, G. J.; Reichert, B. A.; Sirbaugh, J. R.; Wellborn, S. R.

    1992-01-01

    Many aircraft employ ducts with centerline curvature or changing cross-sectional shape to join the engine with inlet and exhaust components. S-ducts convey air to the engine compressor from the intake and often decelerate the flow to achieve an acceptable Mach number at the engine compressor by increasing the cross-sectional area downstream. Circular-to-rectangular transition ducts are used on aircraft with rectangular exhaust nozzles to connect the engine and nozzle. To achieve maximum engine performance, the ducts should minimize flow total pressure loss and total pressure distortion at the duct exit. Changes in the curvature of the duct centerline or the duct cross-sectional shape give rise to streamline curvature which causes cross stream pressure gradients. Secondary flows can be caused by deflection of the transverse vorticity component of the boundary layer. This vortex tilting results in counter-rotating vortices. Additionally, the adverse streamwise pressure gradient caused by increasing cross-sectional area can lead to flow separation. Vortex pairs have been observed in the exit planes of both duct types. These vortices are due to secondary flows induced by pressure gradients resulting from streamline curvature. Regions of low total pressure are produced when the vortices convect boundary layer fluid into the main flow. The purpose of the present study is to predict the measured flow field in a diffusing S-duct and a circular-to-rectangular transition duct with a full Navier-Stokes computer program, PARC3D, and to compare the numerical predictions with new detailed experimental measurements. The work was undertaken to extend previous studies and to provide additional CFD validation data needed to help model flows with strong secondary flow and boundary layer separation. The S-duct computation extends the study of Smith et al, and Harloff et al, which concluded that the computation might be improved by using a finer grid and more advanced turbulence models

  2. Investigation in the 7-By-10 Foot Wind Tunnel of Ducts for Cooling Radiators Within an Airplane Wing, Special Report

    NASA Technical Reports Server (NTRS)

    Harris, Thomas A.; Recant, Isidore G.

    1938-01-01

    An investigation was made in the NACA 7- by 10-foot wind tunnel of a large-chord wing model with a duct to house a simulated radiator suitable for a liquid-cooled engine. The duct was expanded to reduce the radiator losses, and the installation of the duct and radiator was made entirely within the wing to reduce form and interference drag. The tests were made using a two-dimensional flow set-up with a full-span duct and radiator. Section aerodynamic characteristics of the basic airfoil are given and also curves showing the characteristics of the various duct-radiator combinations. An expression for efficiency, the primary criterion of merit of any duct, and the effect of the several design parameters of the duct-radiator arrangement are discussed. The problem of throttling is considered and a discussion of the power required for cooling is included. It was found that radiators could be mounted in the wing and efficiently pass enough air for cooling with duct outlets located at any point from 0.25c to 0.70c from the wing leading edge on the upper surface. The duct-inlet position was found to be critical and, for maximum efficiency, had to be at the stagnation point of the airfoil and to change with flight attitude. The flow could be efficiently throttled only by a simultaneous variation of duct inlet and outlet sizes and of inlet position. It was desirable to round both inlet and outlet lips. With certain arrangements of duct, the power required for cooling at high speed was a very low percentage of the engine power.

  3. Salivary duct carcinoma of parotid gland.

    PubMed

    Kinnera, Vijay Sreedhar Babu; Mandyam, Kumaraswamy Reddy; Chowhan, Amit Kumar; Nandyala, Rukmangadha; Bobbidi, Venkata Phaneendra; Vutukuru, Venkatarami Reddy

    2009-07-01

    A 40-year old male presented with rapidly growing swelling in the right parotid region. Based on the fine needle aspiration cytology report of adenocarcinoma not otherwise specified, superficial parotidectomy was performed, which showed the features of salivary duct carcinoma by histopathological examination. The smears were reviewed to identify the potential pitfalls in the cytological diagnosis of salivary duct carcinoma. PMID:21887008

  4. Salivary duct carcinoma of parotid gland

    PubMed Central

    Kinnera, Vijay Sreedhar Babu; Mandyam, Kumaraswamy Reddy; Chowhan, Amit Kumar; Nandyala, Rukmangadha; Bobbidi, Venkata Phaneendra; Vutukuru, Venkatarami Reddy

    2009-01-01

    A 40-year old male presented with rapidly growing swelling in the right parotid region. Based on the fine needle aspiration cytology report of adenocarcinoma not otherwise specified, superficial parotidectomy was performed, which showed the features of salivary duct carcinoma by histopathological examination. The smears were reviewed to identify the potential pitfalls in the cytological diagnosis of salivary duct carcinoma. PMID:21887008

  5. Double-duct liquid metal magnetohydrodynamic engine

    DOEpatents

    Haaland, Carsten M.

    1995-01-01

    An internal combustion, liquid metal (LM) magnetohydrodynamic (MHD) engine and an alternating current (AC) magnetohydrodynamic generator, are used in combination to provide useful AC electric energy output. The engine design has-four pistons and a double duct configuration, with each duct containing sodium potassium liquid metal confined between free pistons located at either end of the duct. The liquid metal is forced to flow back and forth in the duct by the movement of the pistons, which are alternatively driven by an internal combustion process. In the MHD generator, the two LM-MHD ducts pass in close proximity through a Hartmann duct with output transformer. AC power is produced by operating the engine with the liquid metal in the two generator ducts always flowing in counter directions. The amount of liquid metal maintained in the ducts may be varied. This provides a variable stroke length for the pistons. The engine/generator provides variable AC power at variable frequencies that correspond to the power demands of the vehicular propulsion. Also the engine should maintain nearly constant efficiency throughout the range of power usage. Automobiles and trucks could be powered by the invention, with no transmission or power converter devices being required.

  6. Double-duct liquid metal magnetohydrodynamic engine

    DOEpatents

    Haaland, Carsten M.

    1997-01-01

    An internal combustion, liquid metal (LM) magnetohydrodynamic (MHD) engine and an alternating current (AC) magnetohydrodynamic generator, are used in combination to provide useful AC electric energy output. The engine design has four pistons and a double duct configuration, with each duct containing sodium potassium liquid metal confined between free pistons located at either end of the duct. The liquid metal is forced to flow back and forth in the duct by the movement of the pistons, which are alternatively driven by an internal combustion process. In the MHD generator, the two LM-MHD ducts pass in close proximity through a Hartmann duct with output transformer. AC power is produced by operating the engine with the liquid metal in the two generator ducts always flowing in counter directions. The amount of liquid metal maintained in the ducts may be varied. This provides a variable stroke length for the pistons. The engine/generator provides variable AC power at variable frequencies that correspond to the power demands of the vehicular propulsion. Also the engine should maintain nearly constant efficiency throughout the range of power usage. Automobiles and trucks could be powered by the invention, with no transmission or power converter devices being required.

  7. Tear-Duct Obstruction and Surgery

    MedlinePlus

    ... could block a duct, but reconstructive surgery right after the accident or injury may prevent this. Signs of Blocked Tear Ducts ... kids. It may take up to a week after surgery before symptoms improve. Your doctor will give you antibiotic ointment or drops along with ... Injuries Pinkeye (Conjunctivitis) Retinopathy of Prematurity Preparing Your Child ...

  8. Predicting vibrational failure of flexible ducting

    NASA Technical Reports Server (NTRS)

    Henry, R. H.

    1971-01-01

    Technique applies to liquid or gas transfer through flexible ducting and proves valuable in high velocity fluid flow cases. Fluid mechanism responsible for free bellows vibrational excitation also causes flexible hose oscillation. Static pressure stress influences flexible ducting fatigue life and is considered separately.

  9. Rocket-in-a-Duct Performance Analysis

    NASA Technical Reports Server (NTRS)

    Schneider, Steven J.; Reed, Brian D.

    1999-01-01

    An axisymmetric, 110 N class, rocket configured with a free expansion between the rocket nozzle and a surrounding duct was tested in an altitude simulation facility. The propellants were gaseous hydrogen and gaseous oxygen and the hardware consisted of a heat sink type copper rocket firing through copper ducts of various diameters and lengths. A secondary flow of nitrogen was introduced at the blind end of the duct to mix with the primary rocket mass flow in the duct. This flow was in the range of 0 to 10% of the primary massflow and its effect on nozzle performance was measured. The random measurement errors on thrust and massflow were within +/-1%. One dimensional equilibrium calculations were used to establish the possible theoretical performance of these rocket-in-a-duct nozzles. Although the scale of these tests was small, they simulated the relevant flow expansion physics at a modest experimental cost. Test results indicated that lower performance was obtained at higher free expansion area ratios and longer ducts, while, higher performance was obtained with the addition of secondary flow. There was a discernable peak in specific impulse efficiency at 4% secondary flow. The small scale of these tests resulted in low performance efficiencies, but prior numerical modeling of larger rocket-in-a-duct engines predicted performance that was comparable to that of optimized rocket nozzles. This remains to be proven in large-scale, rocket-in-a-duct tests.

  10. Fabrication process of a high temperature polymer matrix engine duct

    NASA Technical Reports Server (NTRS)

    Pratt, R. D.; Wilson, A. J.

    1985-01-01

    The process that was used in the molding of an advanced composite outer by-pass duct planned for the F404 engine is discussed. This duct was developed as a potential replacement for the existing titanium duct in order to reduce both the weight and cost of the duct. The composite duct is now going into the manufacturing technology portion of the program. The duct is fabricated using graphite cloth impregnated with the PMR-15 matrix system.

  11. Film condensation in a horizontal rectangular duct

    NASA Technical Reports Server (NTRS)

    Lu, Qing; Suryanarayana, N. V.

    1992-01-01

    Condensation heat transfer in an annular flow regime with and without interfacial waves was experimentally investigated. The study included measurements of heat transfer rate with condensation of vapor flowing inside a horizontal rectangular duct and experiments on the initiation of interfacial waves in condensation, and adiabatic air-liquid flow. An analytical model for the condensation was developed to predict condensate film thickness and heat transfer coefficients. Some conclusions drawn from the study are that the condensate film thickness was very thin (less than 0.6 mm). The average heat transfer coefficient increased with increasing the inlet vapor velocity. The local heat transfer coefficient decreased with the axial distance of the condensing surface, with the largest change at the leading edge of the test section. The interfacial shear stress, which consisted of the momentum shear stress and the adiabatic shear stress, appeared to have a significant effect on the heat transfer coefficients. In the experiment, the condensate flow along the condensing surface experienced a smooth flow, a two-dimensional wavy flow, and a three-dimensional wavy flow. In the condensation experiment, the local wave length decreased with the axial distance of the condensing surface and the average wave length decreased with increasing inlet vapor velocity, while the wave speed increased with increasing vapor velocity. The heat transfer measurements are reliable. And, the ultrasonic technique was effective for measuring the condensate film thickness when the surface was smooth or had waves of small amplitude.

  12. Salivary Duct Cyst: Histo-pathologic Correlation

    PubMed Central

    Vinayachandran, Divya; Sankarapandian, Sathasivasubramanian

    2013-01-01

    Non-neoplastic cysts of the salivary glands are uncommon and represent 2-5% of all salivary gland lesions. They are mainly mucoceles or salivary duct cysts. Unlike a mucocele, which is surrounded by granulation tissue, the salivary duct cyst is lined by epithelium. Salivary duct cysts are more common in the oral minor salivary glands and rarely occur in the major salivary glands, show a marked predilection for the superficial lobe of the parotid, and represent 10% of all salivary gland cysts. Neoplastic differentiation of the lining of the salivary duct cyst has been reported. We report a case of a salivary duct cyst of the left parotid gland, with a review of radiographic and histopathologic features. PMID:23878772

  13. Salivary Duct Cyst: Histo-pathologic Correlation.

    PubMed

    Vinayachandran, Divya; Sankarapandian, Sathasivasubramanian

    2013-01-01

    Non-neoplastic cysts of the salivary glands are uncommon and represent 2-5% of all salivary gland lesions. They are mainly mucoceles or salivary duct cysts. Unlike a mucocele, which is surrounded by granulation tissue, the salivary duct cyst is lined by epithelium. Salivary duct cysts are more common in the oral minor salivary glands and rarely occur in the major salivary glands, show a marked predilection for the superficial lobe of the parotid, and represent 10% of all salivary gland cysts. Neoplastic differentiation of the lining of the salivary duct cyst has been reported. We report a case of a salivary duct cyst of the left parotid gland, with a review of radiographic and histopathologic features. PMID:23878772

  14. Laparoscopic Anatomical Left Hepatectomy for Intrahepatic Bile Duct Papillary Mucinous Cystadenoma With Intraoperative Vascular Repair: A Case Report.

    PubMed

    Li, Hongyu; Peng, Bing

    2016-02-01

    Laparoscopic hepatectomy has been widely performed for patients with benign liver tumors such as hepatic hemangioma, focal nodular hyperplasia, and hepatic adenoma.We here present a case of a 78-year-old female patient who was initially admitted to our department due to fever and jaundice for 2 days. Abdominal enhanced computed tomography scan showed intrahepatic and extrahepatic bile duct dilatation with liver atrophy of left lobe. Unenhanced nodules were seen within the left intrahepatic bile duct. Ultrasonography revealed intrahepatic and extrahepatic bile duct dilatation with viscous fluid, tubular adenoma? Tumor markers including alpha fetoprotein, carcinoembryonic antigen, and CA19-9 were normal. Preoperative total bilirubin was 64.4 mmol/L.Laparoscopic anatomical left hepatectomy and common bile duct exploration were performed. In this procedure, a lot of mucus was seen within the common bile duct and left intrahepatic bile duct. No bile duct stones were found after the exploration. During parenchymal transection, intraoperative hemorrhage from middle hepatic vein was met, and we repaired middle hepatic vein by laparoscopic suture (5-0 Prolene). No air embolism and hypotension were met. This operation took 232 minutes and estimated blood loss was 300 mL. Postoperative ultrasonography indicated a normal outflow of middle hepatic vein and there was no stricture. The patient's postoperative course was uneventful and was discharged on the 6th day after surgery. Postoperative pathological diagnosis was intrahepatic bile duct papillary mucinous cystadenoma. PMID:26871845

  15. Electromagnetic propagation in PEC and absorbing curved S-ducts

    NASA Technical Reports Server (NTRS)

    Baumeister, Kenneth J.

    1988-01-01

    A finite-element Galerkin formulation has been developed to study transverse magnetic (TM) wave propagation in 2-D S-curved ducts with both perfectly conducting and absorbing walls. The reflection and transmission at the entrances and the exits of the curved ducts are determined by coupling the finite-element solutions in the curved ducts to the eigenfunctions of an infinite, uniform, perfectly conducting duct. Example solutions are presented for a double mitred and S-ducts of various lengths. The length of the S-duct is found to significantly effect the reflective characteristics of the duct. Also, the effect of curvature on an absorbing duct is illustrated.

  16. MINIMIZING DECOMPOSITION OF VAPORIZED HYDROGEN PEROXIDE IN CLEAN GALVANIZED STEEL DUCTING: IMPLICATIONS FOR BIOLOGICAL DECONTAMINATION

    SciTech Connect

    Verce, M F; Jayaraman, B; Ford, T D; Fisher, S E; Gadgil, A J; Carlsen, T M

    2007-09-07

    This work examined the behavior of vaporous hydrogen peroxide (VHP) in clean, room-scale galvanized steel (GS) and polyvinylchloride-coated steel air ducts, to understand how it might be used to decontaminate larger ventilation systems. VHP injected into the GS duct decreased in concentration along the length of the duct, whereas VHP concentrations in the polyvinylchloride coated duct remained essentially constant, suggesting that VHP decomposed at the GS surface. However, decomposition was reduced at lower temperatures ({approx} 22 C) and higher flow rates ({approx} 80 actual cubic meter per hour). A computational fluid dynamics model incorporating reactive transport was used to estimate surface VHP concentrations where contamination is likely to reside, and also showed how bends encourage VHP decomposition. Use of G. stearothermophilus indicators, in conjunction with model estimates, indicated that a concentration-contact time of {approx} 100 mg/L H{sub 2}O{sub 2}(g){center_dot}min was required to achieve a 6 log reduction of indicator spores in clean GS duct, at 30 C. When VHP is selected for building decontamination, this work suggests the most efficacious strategy may be to decontaminate GS ducting separately from the rest of the building, as opposed to a single decontamination event in which the ventilation system is used to distribute VHP throughout the entire building.

  17. Mixed convection heat and mass transfer in radially rotating rectangular ducts

    SciTech Connect

    Lee, K.T.; Yan, W.M.

    1998-11-27

    Heat transfer in rotating ducts is encountered in many engineering applications, such as cooling of turbomachinery, gas turbines, and other rotating systems. The present work investigates mixed convection heat and mass transfer in the entrance region of radially rotating rectangular ducts with water film evaporation along the porous duct walls. Mechanisms of secondary vortex development in the ducts under various conditions are examined by a vorticity-velocity numerical method. Emphasis is placed on the rotation effects, including both Coriolis and centrifugal buoyancy forces, and the mass diffusion effect on the flow structure and heat transfer characteristics. Results are presented in particular for an air-water vapor system under various conditions. Predicted results show that the effects of liquid film evaporation along the porous duct walls on the mixed convection heat transfer are rather substantial. The magnitude of the evaporative latent heat transfer may be 10 times greater than that of sensible heat transfer. The predictions also demonstrate that the distributions of Nu, Sh{sub z}, and fRe are closely related to the emergence, disappearance, growth, and decay of the rotating-induced secondary vortices. Additionally, a higher Nu{sub z} is found for a rectangular duct with a larger aspect ratio ({gamma} = 2) due to the relatively stronger secondary flows.

  18. Field investigation of duct system performance in California light commercial buildings

    SciTech Connect

    Delp, W.W.; Matson, N.E.; Tschudy, E.

    1997-12-09

    This paper discusses field measurements of duct system performance in fifteen systems located in eight northern California buildings. Light commercial buildings, one- and two-story with package roof-top HVAC units, make up approximately 50% of the non-residential building stock in the U.S. Despite this fact little is known about the performance of these package roof-top units and their associated ductwork. These simple systems use similar duct materials and construction techniques as residential systems (which are known to be quite leaky). This paper discusses a study to characterize the buildings, quantify the duct leakage, and analyze the performance of the ductwork in these types of buildings. The study tested fifteen systems in eight different buildings located in northern California. All of these buildings had the ducts located in the cavity between the drop ceiling and the roof deck. In 50% of these buildings, this cavity was functionally outside the building`s air and thermal barriers. The effective leakage area of the ducts in this study was approximately 2.6 times that in residential buildings. This paper looks at the thermal analysis of the ducts, from the viewpoint of efficiency and thermal comfort. This includes the length of a cycle, and whether the fan is always on or if it cycles with the cooling equipment. 66% of the systems had frequent on cycles of less than 10 minutes, resulting in non-steady-state operation.

  19. An inlet/sampling duct for airborne OH and sulfuric acid measurements

    NASA Astrophysics Data System (ADS)

    Eisele, F. L.; Mauldin, R. L.; Tanner, D. J.; Fox, J. R.; Mouch, T.; Scully, T.

    1997-12-01

    An inlet assembly has been designed, tested, and used for the airborne measurements of OH and sulfuric acid. The inlet sampling duct, which incorporates a shroud connected to two nested, restricted flow ducts, slows air velocity by approximately a factor of 16 while maintaining a uniform and well-defined flow. Qualitative wind tunnel tests showed that an inlet shroud that incorporates a 3:1 inner surface and 4.5:1 outer elliptical front surface can straighten the airflow at angles of attack of up to 18°-20° with no visible signs of turbulence. Tests using a Pitot tube to scan the flow velocity profile of the restricted flow ducts showed that the shroud, coupled to inlet ducts, could slow the flow and provide a relatively flat average velocity profile across the central portion of the ducts at angles of attack up to 17°. Tests performed using a chemical tracer showed that at angles of attack where the Pitot tube measurements began to indicate slight flow instabilities (17°-24°), there was no mixing from the walls into the center of the inlet. The inlet assembly also possesses the ability to produce a fairly uniform concentration of OH in the relatively constant velocity portion of the inner duct for instrument calibration. Actual measurements of rapidly changing OH and H2SO4 provide both additional evidence of proper inlet operation and new insight into H2SO4 production and loss in and around clouds.

  20. Computational Fluid Dynamics Analysis of Flexible Duct Junction Box Design

    SciTech Connect

    Beach, Robert; Prahl, Duncan; Lange, Rich

    2013-12-01

    IBACOS explored the relationships between pressure and physical configurations of flexible duct junction boxes by using computational fluid dynamics (CFD) simulations to predict individual box parameters and total system pressure, thereby ensuring improved HVAC performance. Current Air Conditioning Contractors of America (ACCA) guidance (Group 11, Appendix 3, ACCA Manual D, Rutkowski 2009) allows for unconstrained variation in the number of takeoffs, box sizes, and takeoff locations. The only variables currently used in selecting an equivalent length (EL) are velocity of air in the duct and friction rate, given the first takeoff is located at least twice its diameter away from the inlet. This condition does not account for other factors impacting pressure loss across these types of fittings. For each simulation, the IBACOS team converted pressure loss within a box to an EL to compare variation in ACCA Manual D guidance to the simulated variation. IBACOS chose cases to represent flows reasonably correlating to flows typically encountered in the field and analyzed differences in total pressure due to increases in number and location of takeoffs, box dimensions, and velocity of air, and whether an entrance fitting is included. The team also calculated additional balancing losses for all cases due to discrepancies between intended outlet flows and natural flow splits created by the fitting. In certain asymmetrical cases, the balancing losses were significantly higher than symmetrical cases where the natural splits were close to the targets. Thus, IBACOS has shown additional design constraints that can ensure better system performance.

  1. CHARACTERIZATION OF LEAK PATHWAYS IN THE BELOW GRADE DUCTS OF THE BROOKHAVEN GRAPHITE RESEARCH REACTOR USING PERFLUOROCARBON TRACERS.

    SciTech Connect

    HEISER,J.; SULLIVAN,T.; KALB,P.; MILIAN,L.; WILKE,R.; NEWSON,C.; LILIMPAKIS,M.

    2001-04-01

    The focus of this program was the characterization of the soils beneath the main air ducts connecting the exhaust plenums with the Fan House. The air plenums experienced water intrusion during BGRR operations and after shutdown. The water intrusions were attributed to rainwater leaks into degraded parts of the system and to internal cooling water system leaks. As part of the overall characterization efforts, a state-of-the-art gaseous perfluorocarbon tracer technology was utilized to characterize leak pathways from the ducts. This in turn suggests what soil regions under or adjacent to the ductwork should be emphasized in the characterization process. Knowledge of where gaseous tracers leak from the ducts yields a conservative picture of where water transport, out of or into, the ducts might have occurred.

  2. Turbofan engine with a low pressure turbine driven supercharger in a bypass duct operated by a fuel rich combustor and an afterburner

    NASA Technical Reports Server (NTRS)

    Bartos, James W. (Inventor)

    1999-01-01

    A multiple bypass turbofan engine includes a core Brayton Cycle gas generator with a fuel rich burning combustor and is provided with a variable supercharged bypass duct around the gas generator with a supercharging means in the supercharged bypass duct powered by a turbine not mechanically connected to the gas generator. The engine further includes a low pressure turbine driven forward fan upstream and forward of an aft fan and drivingly connected to a low pressure turbine by a low pressure shaft, the low pressure turbine being aft of and in serial flow communication with the core gas generator. A fan bypass duct is disposed radially outward of the core engine assembly and has first and second inlets disposed between the forward and aft fans. An inlet duct having an annular duct wall is disposed radially inward of the bypass duct and connects the second inlet to the bypass duct. A supercharger means for compressing air is drivingly connected to the low pressure turbine and is disposed in the inlet duct. A secondary combustor or augmentor is disposed in an exhaust duct downstream of and in fluid flow communication with the bypass duct and the gas generator.

  3. A preliminary study on the application of remotely sensed SST in locating evaporation duct height

    NASA Astrophysics Data System (ADS)

    Baig, Muhammad Hasan Ali; Wang, Zhenhui; Zhang, Lifu; Yang, Lu

    2012-10-01

    Refractivity happens due to stratification in the lower boundary layer over oceans due to variability of moisture, temperature, wind and sea surface temperature which collectively may lead to generate evaporation duct. The evaporation duct has a significant impact on the spread of electromagnetic waves in the atmosphere over oceans both from the meteorological and military point of view. This ducting sometimes supports normal propagation of radar signals and sometimes may cause distortion and attenuation of signals depending on the height of evaporation duct. This leads to over-estimation and under-estimation of rainfall by weather radar meteorologically and for other targets militarily. The aim of this study was not only to locate evaporation duct height but also to check the efficiency of Weather Research and Forecasting Model (WRF) and Babin's model so that results may be used in applying correction measures for precise identification of targets by radar. In this study by utilizing the high vertical resolution of WRF for the simulation of different meteorological parameters, the Babin's method was used for calculating the evaporation duct height over South China Sea for the two months, April and July. Very clear duct heights were calculated at different areas over sea in different time domains. Study reveals that maximum height existed in the month of April although July was rich with different EDHs in different regions in contrast to April. It was found that in most of the cases EDH was higher or maximum when relative humidity was comparatively lower and air temperature and wind speed were comparatively higher. This study paves a way for futuristic study of evaporation duct monitoring and forecasting by assimilation of remote sensing data especially through that of Geostationary satellites by incorporating verification measures from radar.

  4. Advanced Turbofan Duct Liner Concepts

    NASA Technical Reports Server (NTRS)

    Bielak, Gerald W.; Premo, John W.; Hersh, Alan S.

    1999-01-01

    The Advanced Subsonic Technology Noise Reduction Program goal is to reduce aircraft noise by 10 EPNdB by the year 2000 relative, to 1992 technology. The improvement goal for nacelle attenuation is 25% relative to 1992 technology by 1997 and 50% by 2000. The Advanced Turbofan Duct Liner Concepts Task work by Boeing presented in this document was in support of these goals. The basis for the technical approach was a Boeing study conducted in 1993-94 under NASA/FAA contract NAS1-19349, Task 6, investigating broadband acoustic liner concepts. As a result of this work, it was recommended that linear double layer, linear and perforate triple layer, parallel element, and bulk absorber liners be further investigated to improve nacelle attenuations. NASA LaRC also suggested that "adaptive" liner concepts that would allow "in-situ" acoustic impedance control also be considered. As a result, bias flow and high-temperature liner concepts were also added to the investigation. The major conclusion from the above studies is that improvements in nacelle liner average acoustic impedance characteristics alone will not result in 25% increased nacelle noise reduction relative to 1992 technology. Nacelle design advancements currently being developed by Boeing are expected to add 20-40% more acoustic lining to hardwall regions in current inlets, which is predicted to result in and additional 40-80% attenuation improvement. Similar advancements are expected to allow 10-30% more acoustic lining in current fan ducts with 10-30% more attenuation expected. In addition, Boeing is currently developing a scarf inlet concept which is expected to give an additional 40-80% attenuation improvement for equivalent lining areas.

  5. Gas turbine engine adapted for use in combination with an apparatus for separating a portion of oxygen from compressed air

    DOEpatents

    Bland, Robert J.; Horazak, Dennis A.

    2012-03-06

    A gas turbine engine is provided comprising an outer shell, a compressor assembly, at least one combustor assembly, a turbine assembly and duct structure. The outer shell includes a compressor section, a combustor section, an intermediate section and a turbine section. The intermediate section includes at least one first opening and at least one second opening. The compressor assembly is located in the compressor section to define with the compressor section a compressor apparatus to compress air. The at least one combustor assembly is coupled to the combustor section to define with the combustor section a combustor apparatus. The turbine assembly is located in the turbine section to define with the turbine section a turbine apparatus. The duct structure is coupled to the intermediate section to receive at least a portion of the compressed air from the compressor apparatus through the at least one first opening in the intermediate section, pass the compressed air to an apparatus for separating a portion of oxygen from the compressed air to produced vitiated compressed air and return the vitiated compressed air to the intermediate section via the at least one second opening in the intermediate section.

  6. ASU nitrogen sweep gas in hydrogen separation membrane for production of HRSG duct burner fuel

    DOEpatents

    Panuccio, Gregory J.; Raybold, Troy M.; Jamal, Agil; Drnevich, Raymond Francis

    2013-04-02

    The present invention relates to the use of low pressure N2 from an air separation unit (ASU) for use as a sweep gas in a hydrogen transport membrane (HTM) to increase syngas H2 recovery and make a near-atmospheric pressure (less than or equal to about 25 psia) fuel for supplemental firing in the heat recovery steam generator (HRSG) duct burner.

  7. EVALUATING THE POTENTIAL EFFICACY OF AN ANTIMICROBIAL-CONTAINING SEALANT ON DUCT LINER AND GALVANIZED STEEL

    EPA Science Inventory

    The article gives results of an evaluation of the potential efficacy of an antimicrobial-containing sealant on fibrous-glass duct liner (FGDL) and galvanized steel (GS) as used in heating, ventilating, and air-conditioning (HVAC) systems. HVAC systems become dirty to various degr...

  8. Development of an Experimental Rig for Investigation of Higher Order Modes in Ducts

    NASA Technical Reports Server (NTRS)

    Gerhold, Carl H.; Cabell, Randolph H.; Brown, Martha C.

    2006-01-01

    Continued progress to reduce fan noise emission from high bypass ratio engine ducts in aircraft increasingly relies on accurate description of the sound propagation in the duct. A project has been undertaken at NASA Langley Research Center to investigate the propagation of higher order modes in ducts with flow. This is a two-pronged approach, including development of analytic models (the subject of a separate paper) and installation of a laboratory-quality test rig. The purposes of the rig are to validate the analytical models and to evaluate novel duct acoustic liner concepts, both passive and active. The dimensions of the experimental rig test section scale to between 25% and 50% of the aft bypass ducts of most modern engines. The duct is of rectangular cross section so as to provide flexibility to design and fabricate test duct liner samples. The test section can accommodate flow paths that are straight through or offset from inlet to discharge, the latter design allowing investigation of the effect of curvature on sound propagation and duct liner performance. The maximum air flow rate through the duct is Mach 0.3. Sound in the duct is generated by an array of 16 high-intensity acoustic drivers. The signals to the loudspeaker array are generated by a multi-input/multi-output feedforward control system that has been developed for this project. The sound is sampled by arrays of flush-mounted microphones and a modal decomposition is performed at the frequency of sound generation. The data acquisition system consists of two arrays of flush-mounted microphones, one upstream of the test section and one downstream. The data are used to determine parameters such as the overall insertion loss of the test section treatment as well as the effect of the treatment on a modal basis such as mode scattering. The methodology used for modal decomposition is described, as is a description of the mode generation control system. Data are presented which demonstrate the performance

  9. Duct Remediation Program: Remediation operations and implementation

    SciTech Connect

    Beckman, T.d.; Davis, M.M.; Karas, T.M.

    1992-11-01

    Plutonium holdup material has accumulated in the process ventilation duct systems at Rocky Flats. Non-Destructive Assay (NDA) measurements identified ducts containing this material. The Defense Nuclear Facility Safety Board and the Department of Energy established the criteria for remediation of these ducts. A remediation team was assembled and a program plan created. This program plan included activities such as fissile material accumulation identification, criticality safety assessments, radiation dose determinations, facility safety evaluations, prevention of future accumulation, and removal of holdup material. Several operational considerations had to be evaluated in determining completion of remediation.

  10. Magnetospheric whistler ducts observed by ISIS satellites

    NASA Technical Reports Server (NTRS)

    Ondoh, T.

    1976-01-01

    The latitudinal width of the magnetospheric whistler duct has been estimated by the first and final invariant latitudes of whistler echoes and the conservation of the magnetic flux for the centered dipole field, using 105 whistler echoes in ISIS VLF data received at Kashima, Japan for 1972-1973. The latitudinal distribution of whistler duct occurrence shows a maximum at invariant latitudes of 40-45 degrees near the maximum occurrence latitude of ground whistlers. The radial width of magnetospheric whistler duct in the geomagnetically equatorial plane increases with invariant latitude of the geomagnetic flux tube in which whistlers propagate.

  11. 40 CFR 63.6092 - Are duct burners and waste heat recovery units covered by subpart YYYY?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 13 2014-07-01 2014-07-01 false Are duct burners and waste heat recovery units covered by subpart YYYY? 63.6092 Section 63.6092 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) NATIONAL EMISSION STANDARDS FOR HAZARDOUS AIR POLLUTANTS FOR SOURCE CATEGORIES...

  12. 40 CFR 63.6092 - Are duct burners and waste heat recovery units covered by subpart YYYY?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 13 2013-07-01 2012-07-01 true Are duct burners and waste heat recovery units covered by subpart YYYY? 63.6092 Section 63.6092 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) NATIONAL EMISSION STANDARDS FOR HAZARDOUS AIR POLLUTANTS FOR SOURCE CATEGORIES...

  13. Improved on-line thoracic duct drainage for lymphocytapheresis.

    PubMed

    Sato, T; Koga, N; Nagano, T; Ohteki, H; Masuda, T; Agishi, T

    1991-12-01

    Lymphocytapheresis using thoracic duct drainage (TDD) is a recognized technique of extracorporeal immunomodulation for various autoimmune diseases such as rheumatoid arthritis (RA), and its clinical benefit has been reported and generally accepted. Lymphocytapheresis using TDD is very selective for removing lymphocytes (especially helper T-cells) but raises some problems such as hypoproteinemia due to the massive removal of lymph, and difficulties in repeated treatment. Along with the development of a new polyester fiber filter, we have developed a simple and effective method of lymphocytapheresis for wide adoption for these techniques. We performed lymphocytapheresis using TDD in patients with RA and previously reported its clinical efficacy indicated by the significantly lower number of peripheral lymphocytes and T4/T8 ratio. We present here our newly-developed on-line system designed to prevent hypoproteinemia. Furthermore we report on the advantages with a new subcutaneous vascular access device set up to manage the problems of repeated treatments. A small reservoir for keeping the thoracic duct open and returning lymph to the patient permitted sufficient lymph drainage and removal of lymphocytes and the clinical application of TDD is discussed. PMID:1783455

  14. Why Do Staff Return?

    ERIC Educational Resources Information Center

    Magnuson, Connie

    1992-01-01

    Surveyed 211 returning staff from 25 camps and interviewed 19 returning staff to study factors that influence a counselor's decision to return to camp. Examined the following dimensions of motivation and hygiene factors: (1) stimulation or inspiration; (2) personal; (3) job-related experience; (4) living conditions and camp life; (5) camp…

  15. Natural Flow Air Cooled Photovoltaics

    NASA Astrophysics Data System (ADS)

    Tanagnostopoulos, Y.; Themelis, P.

    2010-01-01

    Our experimental study aims to investigate the improvement in the electrical performance of a photovoltaic installation on buildings through cooling of the photovoltaic panels with natural air flow. Our experimental study aims to investigate the improvement in the electrical performance of a photovoltaic installation on buildings through cooling of the photovoltaic panels with natural air flow. We performed experiments using a prototype based on three silicon photovoltaic modules placed in series to simulate a typical sloping building roof with photovoltaic installation. In this system the air flows through a channel on the rear side of PV panels. The potential for increasing the heat exchange from the photovoltaic panel to the circulating air by the addition of a thin metal sheet (TMS) in the middle of air channel or metal fins (FIN) along the air duct was examined. The operation of the device was studied with the air duct closed tightly to avoid air circulation (CLOSED) and the air duct open (REF), with the thin metal sheet (TMS) and with metal fins (FIN). In each case the experiments were performed under sunlight and the operating parameters of the experimental device determining the electrical and thermal performance of the system were observed and recorded during a whole day and for several days. We collected the data and form PV panels from the comparative diagrams of the experimental results regarding the temperature of solar cells, the electrical efficiency of the installation, the temperature of the back wall of the air duct and the temperature difference in the entrance and exit of the air duct. The comparative results from the measurements determine the improvement in electrical performance of the photovoltaic cells because of the reduction of their temperature, which is achieved by the naturally circulating air.

  16. Error analysis for duct leakage tests in ASHRAE standard 152P

    SciTech Connect

    Andrews, J.W.

    1997-06-01

    This report presents an analysis of random uncertainties in the two methods of testing for duct leakage in Standard 152P of the American Society of Heating, Refrigerating, and Air-Conditioning Engineers (ASHRAE). The test method is titled Standard Method of Test for Determining Steady-State and Seasonal Efficiency of Residential Thermal Distribution Systems. Equations have been derived for the uncertainties in duct leakage for given levels of uncertainty in the measured quantities used as inputs to the calculations. Tables of allowed errors in each of these independent variables, consistent with fixed criteria of overall allowed error, have been developed.

  17. Transmission of wave energy in curved ducts

    NASA Technical Reports Server (NTRS)

    Rostafinski, W.

    1973-01-01

    A formation of wave energy flow was developed for motion in curved ducts. A parametric study over a range of frequencies determined the ability of circular bends to transmit energy for the case of perfectly rigid walls.

  18. How Is Bile Duct Cancer Diagnosed?

    MedlinePlus

    ... line through which a different kind of contrast dye (IV contrast) is injected. This helps better outline ... common bile duct. A small amount of contrast dye is injected through the tube to help outline ...

  19. Treatment Options for Extrahepatic Bile Duct Cancer

    MedlinePlus

    ... checked to measure the amounts of bilirubin and alkaline phosphatase released into the blood by the liver. ... which a stent (a thin, flexible tube or metal tube) is placed in the bile duct to ...

  20. Treatment Option Overview (Extrahepatic Bile Duct Cancer)

    MedlinePlus

    ... checked to measure the amounts of bilirubin and alkaline phosphatase released into the blood by the liver. ... which a stent (a thin, flexible tube or metal tube) is placed in the bile duct to ...

  1. Stages of Extrahepatic Bile Duct Cancer

    MedlinePlus

    ... checked to measure the amounts of bilirubin and alkaline phosphatase released into the blood by the liver. ... which a stent (a thin, flexible tube or metal tube) is placed in the bile duct to ...

  2. Bile Duct (Cholangiocarcinoma) Cancer: Radiation Therapy

    MedlinePlus

    ... form of radiation for bile duct cancer. External beam radiation therapy (EBRT) This type of radiation therapy ... determine the correct angles for aiming the radiation beams and the proper dose of radiation. The treatment ...

  3. Intraoperative cholangiography and bile duct injury.

    PubMed

    Sarli, L; Costi, R; Roncoroni, L

    2006-01-01

    We are not in agreement with the opinion that the credit for excellent results after laparoscopic cholecystectomy is to be attributed to the routine performing of intraoperative cholangiography. We performed 2538 laparoscopic cholecystectomies without routine intraoperative cholangiography and we obtained very low rate and severity of common bile duct injuries: there was a total of four common bile duct injuries (0.16%), in no case was the injury a major transaction, and injuries were detected intraoperatively and easily repaired with a T-tube. Cholangiography could prevent bile duct transaction, but that it is not necessary for intraoperative cholangiography to be routinely performed for this purpose. It is sufficient for intraoperative cholangiography to be performed whenever the surgeon is in doubt as to the biliary anatomy or common bile duct clearance, and that when dissection of the cholecystic peduncle proves difficult he does not hesitate to convert to open access. PMID:16333543

  4. Investigation of heat transfer in porous duct

    NASA Astrophysics Data System (ADS)

    Athani, Abdulgaphur; Khan, T. M. Yunus

    2016-05-01

    Investigation of heat transfer in a square porous duct is carried out. The porous medium is sandwiched between inner and outer surface of a square duct. The flow is assumed to follow the Darcy law. The governing momentum and energy equations are non-dimensionalised and then converted to algebraic form of equations using finite element method. Galerkin method is used to transform the partial differential equations into simpler algebraic equations then solved in a iterative manner to arrive at the solution. The results are presented with respect to various geometric and physical parameters such as depth of porous medium, Rayleigh number etc. It is found that the isotherms and the streamlines take symmetrical position along the vertical central line of square duct. The isotherms are penetrated into deeper area at upper half of duct as compared to lower half.

  5. Model for coal dust duct explosions

    SciTech Connect

    Pickles, J.H.

    1982-01-01

    A theoretical discussion is given of the propagation of a dust explosion in a linear duct or pipeline. The particular aim is to investigate the experimental observation that propagating explosions are much harder to initiate in small laboratory scale ducts than in, say, coal mine galleries. A model is proposed in which a turbulent mixing phenomenon first identified by G.I. Taylor gives, for large ducts, very high flame velocities, which in turn lead to large fluid velocities and further increases in flame velocity. In small ducts, the time scale of the turbulent mixing is less than the time needed for the burning of individual coal particles. The particle burning time becomes an additional constraint on the rate of flame propagation and the development of explosions is inhibited.

  6. Rotating Rake Turbofan Duct Mode Measurement System

    NASA Technical Reports Server (NTRS)

    Sutliff, Daniel L.

    2005-01-01

    An experimental measurement system was developed and implemented by the NASA Glenn Research Center in the 1990s to measure turbofan duct acoustic modes. The system is a continuously rotating radial microphone rake that is inserted into the duct. This Rotating Rake provides a complete map of the acoustic duct modes present in a ducted fan and has been used on a variety of test articles: from a low-speed, concept test rig, to a full-scale production turbofan engine. The Rotating Rake has been critical in developing and evaluating a number of noise reduction concepts as well as providing experimental databases for verification of several aero-acoustic codes. More detailed derivation of the unique Rotating Rake equations are presented in the appendix.

  7. [Isolated neurofibroma of the common bile duct].

    PubMed

    Carbia, S; Pagola, J; Flaster, N; Guida, A; Jufe, L; González, B; Caniparoli, A

    1995-01-01

    The neurogenic tumors in the biliary tract are rare and usually are amputation neuroma that occur after cholecystectomy. We describe a case of isolated neurofibroma of the common bile duct in a young man not cholecystectomized. The patient suffered recurrent episodes of abdominal pain, vomiting and weight loss without clinical signs of Von Recklinghausen's disease or jaundice. The hepatogram was normal. The echography indicated a solid formation with obstruction of the proximal common bile duct. In the ERCP the stenosis was found. Surgical excision of the tumor and anastomosis of bilateral hepatic ducts and jejunum were carried out. At microscopic examination intraparietal neurofibroma of the common bile duct was found. As isolated entity, we know of only one reported case. PMID:8731581

  8. Device for Measuring Low Flow Speed in a Duct

    NASA Technical Reports Server (NTRS)

    Quinn, Frank; Magee, Kevin

    2009-01-01

    A multiple-throat venturi system has been invented for measuring laminar flow of air or other gas at low speed (1 to 30 cm/s) in a duct while preserving the laminar nature of the flow and keeping the velocity profile across the duct as nearly flat as possible. While means for measuring flows at higher speeds are well established, heretofore, there have been no reliable means for making consistent, accurate measurements in this speed range. In the original application for which this system was invented, the duct leads into the test section of a low-speed wind tunnel wherein uniform, low-speed, laminar flow is required for scientific experiments. The system could also be used to monitor a slow flow of gas in an industrial process like chemical vapor deposition. In the original application, the multiple- throat venturi system is mounted at the inlet end of the duct having a rectangular cross section of 19 by 14 cm, just upstream of an assembly of inlet screens and flow straighteners that help to suppress undesired flow fluctuations (see Figure 1). The basic venturi measurement principle is well established: One measures the difference in pressure between (1) a point just outside the inlet, where the pressure is highest and the kinetic energy lowest; and (2) the narrowest part (the throat) of the venturi passage, where the kinetic energy is highest and the pressure is lowest. Then by use of Bernoulli s equation for the relationship between pressure and kinetic energy, the volumetric flow speed in the duct can be calculated from the pressure difference and the inlet and throat widths. The design of this system represents a compromise among length, pressure recovery, uniformity of flow, and complexity of assembly. Traditionally, venturis are used to measure faster flows in narrower cross sections, with longer upstream and downstream passages to maintain accuracy. The dimensions of the passages of the present venturi system are sized to provide a readily measurable

  9. Evaporation duct communication: Test plan, part 2

    NASA Astrophysics Data System (ADS)

    Anderson, K. D.; Rogers, L. T.

    1991-11-01

    This document is a continuation and expansion of an earlier study that examines the feasibility of using the evaporation duct to support an alternative high-speed communication system for Navy applications. This Evaporation Duct Communication (EDCOM) experiment is a unique opportunity to evaluate another communication channel that can alleviate Navy ship-to-ship communication problems. Therefore, it is strongly recommended to proceed with this measurement program.

  10. Mucoepidermoid carcinoma in a thyroglossal duct remnant

    PubMed Central

    Warner, E.; Ofo, E.; Connor, S.; Odell, E.; Jeannon, J.P.

    2015-01-01

    Introduction Thyroglossal duct cysts (TDC) are common midline neck swellings resulting from embryological remnants of the thyroglossal duct. They often contain ectopic thyroid tissue and malignant transformation has been reported, most commonly to papillary thyroid carcinoma. Mucoepidermoid carcinoma (MEC) usually occurs in the salivary glands and only rarely in the thyroid. This is the first case of a MEC occurring within a thyroglossal duct remnant. Presentation of a case A 73 year old lady presented with a thyroglossal duct cyst. She declined surgical excision, as she was adamant she wanted to avoid surgery. The neck mass rapidly enlarged at two years following initial diagnosis. Fine needle aspiration cytology was suspicious for carcinoma. She underwent total thyroidectomy and selective central compartment neck dissection with adjuvant radiotherapy. She remains alive and well two years post treatment. Discussion Mucoepidermoid carcinoma is the most common malignant neoplasm of salivary glands, although it has rarely been reported in diverse locations including the thyroid, lung and pancreas. To the best of our knowledge, this is the first reported case of mucoepidermoid carcinoma arising from a thyroglossal duct remnant. Conclusion This case adds weight to the literature favouring surgical excision of thyroglossal duct remnants due to the risk of malignant transformation. PMID:26101054

  11. Fundamental investigation of duct/ESP phenomena: Flow visualization

    NASA Astrophysics Data System (ADS)

    Brown, C. T.; Sowa, W. A.; Samuelsen, G. S.

    1990-11-01

    The objective is to characterize the performance and behavior of twin-fluid atomizers used for in-duct sulfur capture. Such atomizers characteristically produce dense sprays featuring very narrow dispersion angles and high droplet velocities. To meet the objective, several tasks were identified (1) demonstrate the usefulness of phase Doppler interferometry to characterize humidification atomizers, (2) screen several commercially available atomizers to guide in the selection of nozzles used of field testing, and (3) develop a data base useful for computational code development and validation. The approach taken is to characterize the liquid phase produced by practical, full scale, twin-fluid humidification atomizers. Eight such twin-fluid atomizers are considered. Several of these atomizers were used in field tests. Only water sprays are considered. Atomizer responses to changes in air pressure (air flow rate) and water pressure (water flow rate) are examined. Measurements of droplet size and corresponding mean axial velocity are obtained.

  12. Positive direct current corona discharges in single wire-duct electrostatic precipitators

    NASA Astrophysics Data System (ADS)

    Yehia, Ashraf; Abdel-Fattah, E.; Mizuno, Akira

    2016-05-01

    This paper is aimed to study the characteristics of the positive dc corona discharges in single wire-duct electrostatic precipitators. Therefore, the corona discharges were formed inside dry air fed single wire-duct reactor under positive dc voltage at the normal atmospheric conditions. The corona current-voltage characteristics curves have been measured in parallel with the ozone concentration generated inside the reactor under different discharge conditions. The corona current-voltage characteristics curves have agreed with a semi empirical equation derived from the previous studies. The experimental results of the ozone concentration generated inside the reactor were formulated in the form of an empirical equation included the different parameters that were studied experimentally. The obtained equations are valid to expect both the current-voltage characteristics curves and the corresponding ozone concentration that generates with the positive dc corona discharges inside single wire-duct electrostatic precipitators under any operating conditions in the same range of the present study.

  13. Analysis and consequences of fire inside the ventilation ducts of a nuclear facility

    SciTech Connect

    Briand, A.R.; Laborde, J.C. ); Savornin, J.H.; Tessier, J.L. )

    1989-01-01

    Accident events involving fire are rather frequent and could have a severe effect on the safety of nuclear facilities. Among the fires that have broken out in nuclear plants, several have resulted from ignition of dust deposited inside the ventilation ducts and on the high-efficiency particulate air (HEPA) filters. The BEATRICE test facility has been designed and built at a French nuclear studies center to enable the analysis and consequences of these types of fires to be evaluated. The associated experimental program is aimed at characterizing the fire (fire spread, aerosols formed), determining and simulating the temperature profiles along the duct (thermal losses evaluation by the pipette code), and evaluating the challenge and behavior of the associated HEPA filters (efficiency, contamination release, etc.). The tests performed in this study contributed to improvements in the basic knowledge about fires inside ventilation ducts and define the associated strategies (ventilation control, filters protection, etc.).

  14. Return flux experiment

    NASA Technical Reports Server (NTRS)

    Tveekrem, June L.

    1992-01-01

    All spacecraft emit molecules via outgassing, thruster plumes, vents, etc. The return flux is the portion of those molecules that scatter from the ambient atmosphere and return to the spacecraft. Return flux allows critical spacecraft surfaces to become contaminated even when there is no direct line of sight between the contamination source and the critical surface. Data from the Long Duration Exposure Facility (LDEF) show that contamination of LDEF surfaces could not have come entirely from direct flux. The data suggest significant return flux. Several computer models have been developed to simulate return flux, but the predictions have never been verified in orbit. Large uncertainties in predictions lead to overly conservative spacecraft designs. The purpose of the REturn FLux EXperiment (REFLEX) is to fly a controlled experiment that can be directly compared with predictions from several models.

  15. Assured crew return vehicle

    NASA Technical Reports Server (NTRS)

    Cerimele, Christopher J. (Inventor); Ried, Robert C. (Inventor); Peterson, Wayne L. (Inventor); Zupp, George A., Jr. (Inventor); Stagnaro, Michael J. (Inventor); Ross, Brian P. (Inventor)

    1991-01-01

    A return vehicle is disclosed for use in returning a crew to Earth from low earth orbit in a safe and relatively cost effective manner. The return vehicle comprises a cylindrically-shaped crew compartment attached to the large diameter of a conical heat shield having a spherically rounded nose. On-board inertial navigation and cold gas control systems are used together with a de-orbit propulsion system to effect a landing near a preferred site on the surface of the Earth. State vectors and attitude data are loaded from the attached orbiting craft just prior to separation of the return vehicle.

  16. Effect of radiant barriers and attic ventilation on residential attics and attic duct systems: New tools for measuring and modeling

    SciTech Connect

    Petrie, T.W.; Childs, P.W.; Christian, J.E.; Wilkes, K.E.

    1998-07-01

    A simple duct system was installed in an attic test module for a large scale climate simulator at a US national laboratory. The goal of the tests and subsequent modeling was to develop an accurate method of assessing duct system performance in the laboratory, enabling limiting conditions to be imposed at will and results to be applied to residential attics with attic duct systems. Steady-state tests were done at a severe summer and a mild winter condition. In all tests the roof surface was heated above ambient air temperatures by infrared lights. The attic test module first included then did not include the duct system. Attic ventilation from eave vents to a ridge vent was varied from none to values achievable by a high level of power ventilation. A radiant barrier was attached to the underside of the roof deck, both with and without the duct system in place. Tests were also done without the radiant barrier, both with and without the duct system. When installed, the insulated ducts ran along the floor of the attic, just above the attic insulation and along the edge of the attic near the eaves and one gable. These tests in a climate simulator achieved careful control and reproducibility of conditions. This elucidated dependencies that would otherwise be hidden by variations in uncontrolled variables. Based on the comparisons with the results of the tests at the mild winter condition and the severe summer condition, model predictions for attic air and insulation temperatures should be accurate within {+-} 10 F ({+-} 6 C). This is judged adequate for design purposes and could be better when exploring the effect of changes in attic and duct parameters at fixed climatic conditions.

  17. Size limitations in semicircular duct systems

    PubMed

    Muller

    1999-06-01

    The present article discusses mechanical requirements and limitations which are applicable to the construction of the system of semicircular ducts, especially to its size. The simplified case of a single, uniform duct system has been considered which can be described by a second order equation of motion. The principal functional quantities for this rotation-sensor are: (1) response speed; (2) sensitivity; and (3) regular flow. The response speed of a single, uniform semicircular duct is characterized by the short time constant (T2) which is dependent on the duct radius (r). Its estimated range is from 0.04 ms in the smallest to 140 ms in the largest known labyrinth. The sensitivity is characterized by the maximal endolymph displacement after a step stimulus (xmax). Its estimated range is from 0.0016 &mgr;m to 5.97 mm (6.56 decades!), assuming an input angular velocity of omega=1 rad s-1. The Reynolds number is a measure for an undisturbed laminar flow. Its estimated range varies from 7.38.10(-4)to 45.1 for omega=1 rad s-1. The above data follow from graphs in which, for a single uniform duct, circuit radius (R) is plotted against duct radius (r) for labyrinths of 233 species belonging to different vertebrate-groups. A relation R =38.9. r1.60was determined. The smallest labyrinth was found in a carp larva (Cyprinus), the largest in a whale shark (Rhincodon). Large whales possess labyrinths of average mammalian size. It is revealed that semicircular duct size is bound by requirements concerning regular flow and by a too low response speed for large labyrinths, and by a too low sensitivity for small labyrinths. Other important quantities are mechanical amplification factors which are a consequence of more complex vestibular constructions than a single uniform duct circuit. Allometric relationships are interpreted as compromises between the quantities mentioned. A hypothesis for the relatively large semicircular duct sizes of fishes, especially Elasmobranchii, compared

  18. Remodeling of the Fetal Collecting Duct Epithelium

    PubMed Central

    Hiatt, Michael J.; Ivanova, Larissa; Toran, Nuria; Tarantal, Alice F.; Matsell, Douglas G.

    2010-01-01

    Congenital urinary tract obstruction induces changes to the renal collecting duct epithelium, including alteration and depletion of intercalated cells. To study the effects of obstruction on the ontogeny of intercalated cell development, we examined normal and obstructed human fetal and postnatal kidneys. In the normal human fetal kidney, intercalated cells originated in the medullary collecting duct at 8 weeks gestation and remained most abundant in the inner medulla throughout gestation. In the cortex, intercalated cells were rare at 18 and 26 weeks gestation and observed at low abundance at 36 weeks gestation. Although early intercalated cells exhibit an immature phenotype, Type A intercalated cells predominated in the inner and outer medullae at 26 and 36 weeks gestation with other intercalated cell subtypes observed rarely. Postnatally, the collecting duct epithelium underwent a remodeling whereby intercalated cells become abundant in the cortex yet absent from the inner medulla. In 18-week obstructed kidneys with mild to moderate injury, the intercalated cells became more abundant and differentiated than the equivalent age-matched normal kidney. In contrast, more severely injured ducts of the late obstructed kidney exhibited a significant reduction in intercalated cells. These studies characterize the normal ontogeny of human intercalated cell development and suggest that obstruction induces premature remodeling and differentiation of the fetal collecting duct epithelium. PMID:20035053

  19. Convolution seal for transition duct in turbine system

    SciTech Connect

    Flanagan, James Scott; LeBegue, Jeffrey Scott; McMahan, Kevin Weston; Dillard, Daniel Jackson; Pentecost, Ronnie Ray

    2015-05-26

    A turbine system is disclosed. In one embodiment, the turbine system includes a transition duct. The transition duct includes an inlet, an outlet, and a passage extending between the inlet and the outlet and defining a longitudinal axis, a radial axis, and a tangential axis. The outlet of the transition duct is offset from the inlet along the longitudinal axis and the tangential axis. The transition duct further includes an interface feature for interfacing with an adjacent transition duct. The turbine system further includes a convolution seal contacting the interface feature to provide a seal between the interface feature and the adjacent transition duct.

  20. Energy effectiveness of duct sealing and insulation in two multifamily buildings

    SciTech Connect

    Walker, I.S.; Modera, M.P.; Tuluca, A.; Graham, I. |

    1996-08-01

    Energy losses from forced air distribution systems have a significant impact on the energy efficiency of buildings. Little work has been done to quantify these losses in apartment buildings. In this paper the authors will discuss field measurements made on four forced air heating systems to evaluate the duct system energy losses to unconditioned basements. The apartments were heated by natural gas furnaces located in the basements. The systems had bare sheet metal ductwork exposed to the basement conditions. The pre-retrofit measurements were made on the systems after sealing large easily visible leaks. The post-retrofit measurements were made after wrapping the ducts in foil backed glass fiber insulation and additional leak sealing. Only the sections of duct exposed to the basement were retrofitted because only these sections were accessible. This study examines the potential energy savings for this type of limited retrofit. The energy losses were separated into leakage and conduction terms. Leakage measurements were made using register flowhood techniques. Conduction losses were estimated by measuring temperatures in the plenums and at the registers. Analysis of the measurements has shown typical reduction in leakage flow due to duct sealing of about 40%. The reduction in leakage translated into a reduction in energy consumption of about 10%.

  1. User's Manual for DuctE3D: A Program for 3D Euler Unsteady Aerodynamic and Aeroelastic Analysis of Ducted Fans

    NASA Technical Reports Server (NTRS)

    Srivastava, R.; Reddy, T. S. R.

    1997-01-01

    The program DuctE3D is used for steady or unsteady aerodynamic and aeroelastic analysis of ducted fans. This guide describes the input data required and the output files generated, in using DuctE3D. The analysis solves three dimensional unsteady, compressible Euler equations to obtain the aerodynamic forces. A normal mode structural analysis is used to obtain the aeroelastic equations, which are solved using either the time domain or the frequency domain solution method. Sample input and output files are included in this guide for steady aerodynamic analysis and aeroelastic analysis of an isolated fan row.

  2. "Mustache sign" due to Stensen duct dilation.

    PubMed

    Yoruk, O; Kılıc, K; Kantarcı, M

    2013-12-01

    An 80-year-old woman presented with a 5-year history of painless swellings of the left and right cheeks. The degree of swelling did not change with mastication. On palpation, the cheeks were soft, well defined, and movable. Compression and massage of the swollen areas caused increased salivary discharge from the orifices of the Stensen ducts. Three-dimensional computed tomography showed well-bordered, 15- to 20-mm wide, bilateral, tube-like dilatations of the ducts. The ductal origin of the swellings was explained to the patient, but she refused invasive procedures, thus no sialogram or surgical procedure was performed. We describe the clinical and radiographic features of a case of bilateral, congenital Stensen duct dilatation with bilateral swelling of the cheeks. PMID:24209996

  3. Acoustic energy in ducts - Further observations

    NASA Technical Reports Server (NTRS)

    Eversman, W.

    1979-01-01

    The transmission of acoustic energy in uniform ducts carrying uniform flow is investigated with the purpose of clarifying two points of interest. The two commonly used definitions of acoustic 'energy' flux are shown to be related by a Legendre transformation of the Lagrangian density exactly as in deriving the Hamiltonian density in mechanics. In the acoustic case the total energy density and the Hamiltonian density are not the same which accounts for two different 'energy' fluxes. When the duct has acoustically absorptive walls neither of the two flux expressions gives correct results. A reevaluation of the basis of derivation of the energy density and energy flux provides forms which yield consistent results for soft walled ducts.

  4. Modeling of three-dimensional mixing and reacting ducted flows

    NASA Technical Reports Server (NTRS)

    Zelazny, S. W.; Baker, A. J.; Rushmore, W. L.

    1976-01-01

    A computer code, based upon a finite element solution algorithm, was developed to solve the governing equations for three-dimensional, reacting boundary region, and constant area ducted flow fields. Effective diffusion coefficients are employed to allow analyses of turbulent, transitional or laminar flows. The code was used to investigate mixing and reacting hydrogen jets injected from multiple orifices, transverse and parallel to a supersonic air stream. Computational results provide a three-dimensional description of velocity, temperature, and species-concentration fields downstream of injection. Experimental data for eight cases covering different injection conditions and geometries were modeled using mixing length theory (MLT). These results were used as a baseline for examining the relative merits of other mixing models. Calculations were made using a two-equation turbulence model (k+d) and comparisons were made between experiment and mixing length theory predictions. The k+d model shows only a slight improvement in predictive capability over MLT. Results of an examination of the effect of tensorial transport coefficients on mass and momentum field distribution are also presented. Solutions demonstrating the ability of the code to model ducted flows and parallel strut injection are presented and discussed.

  5. Computing Propagation Of Sound In Engine Ducts

    NASA Technical Reports Server (NTRS)

    Saylor, Silvia

    1995-01-01

    Frequency Domain Propagation Model (FREDOM) computer program accounts for acoustic loads applied to components of engines. Models propagation of noise through fluids in ducts between components and through passages within components. Used not only to analyze hardware problems, but also for design purposes. Updated version of FREQPL program easier to use. Devised specifically for use in analyzing acoustic loads in rocket engines. Underlying physical and mathematical concepts implemented also applicable to acoustic propagation in other enclosed spaces; analyzing process plumbing and ducts in industrial buildings with view toward reducing noise in work areas.

  6. Modern management of common bile duct stones.

    PubMed

    Buxbaum, James

    2013-04-01

    It is imperative for gastroenterologists to understand the different formations of bile duct stones and the various medical treatments available. To minimize the complications of endoscopic retrograde cholangiopancreatography (ERCP), it is critical to appropriately assess the risk of bile duct stones before intervention. Biliary endoscopists should be comfortable with the basic techniques of stone removal, including sphincterotomy, mechanical lithotripsy, and stent placement. It is important to be aware of advanced options, including laser and electrohydraulic stone fragmentation, and papillary dilatation for problematic cases. The timing and need for ERCP in those who require a cholecystectomy is also a consideration. PMID:23540960

  7. Fundamental investigation of duct/ESP phenomena

    SciTech Connect

    Brown, C.A. ); Durham, M.D. ); Sowa, W.A. . Combustion Lab.); Himes, R.M. ); Mahaffey, W.A. )

    1991-10-21

    Radian Corporation was contracted to investigate duct injection and ESP phenomena in a 1.7 MW pilot plant constructed for this test program. This study was an attempt to resolve problems found in previous studies and answer remaining questions for the technology using an approach which concentrates on the fundamental mechanisms of the process. The goal of the study was to obtain a better understanding of the basic physical and chemical phenomena that control: (1) the desulfurization of flue gas by calcium-based reagent, and (2) the coupling of an existing ESP particulate collection device to the duct injection process. Process economics are being studied by others. (VC)

  8. Preconditioning the Helmholtz Equation for Rigid Ducts

    NASA Technical Reports Server (NTRS)

    Baumeister, Kenneth J.; Kreider, Kevin L.

    1998-01-01

    An innovative hyperbolic preconditioning technique is developed for the numerical solution of the Helmholtz equation which governs acoustic propagation in ducts. Two pseudo-time parameters are used to produce an explicit iterative finite difference scheme. This scheme eliminates the large matrix storage requirements normally associated with numerical solutions to the Helmholtz equation. The solution procedure is very fast when compared to other transient and steady methods. Optimization and an error analysis of the preconditioning factors are present. For validation, the method is applied to sound propagation in a 2D semi-infinite hard wall duct.

  9. Congenital Atresia of Wharton’s Duct

    PubMed Central

    Hseu, Anne; Anne, Premchand

    2016-01-01

    This is a case report of a three-month-old male who presented to clinic with a cystic lesion under the tongue. On clinical examination, a cystic lesion was observed in the, floor-of-mouth. The patient was referred to Paediatric Otorhinolaryngology service for further management. The differential diagnoses for floor-of-mouth lesions should be reviewed with primary focus on the Wharton’s duct atresia and its management. It is crucial to recognize submandibular duct atresia in the primary Paediatric clinic in order to expedite management of lesion before complications arise including infection, enlargement of cyst, and feeding and breathing difficulties. PMID:27042492

  10. Air Travel Health Tips

    MedlinePlus

    MENU Return to Web version Air Travel Health Tips Air Travel Health Tips How can I improve plane travel? Most people don't have any problems when ... and dosages of all of your medicines. The air in airplanes is dry, so drink nonalcoholic, decaffeinated ...

  11. What Should You Ask Your Doctor about Bile Duct Cancer?

    MedlinePlus

    ... treatment for bile duct cancer? What should you ask your doctor about bile duct cancer? It is ... your own. For instance, you might want to ask about clinical trials for which you may qualify. ...

  12. Experimental evaluation of a pilot multinozzle-duct apparatus

    NASA Technical Reports Server (NTRS)

    Puster, R. L.

    1979-01-01

    A pilot multinozzle and duct were tested at ambient enthalpy to evaluate the suitability of such apparatus for testing thermal protection system panels mounted in the sidewalls of the duct downstream of the nozzle array. The flow field in the duct was complex: effects of wakes and shock waves from the nozzle dominated the flow field; the wakes continually mixed with the surrounding fluid; the boundary layer on the sidewalls of the duct was nonuniform; and near the exit of the duct the sidewall pressure variation was as much as 8.5 percent about the mean wall pressure. Starting loads on the duct walls were higher than those of a similar conventional nozzle and duct. It was concluded that the multinozzle-duct apparatus was not suitable for testing TPS panels, although the design and flow-field information should be of interest to designers of high-energy gasdynamic lasers.

  13. In-duct identification of fluid-borne source with high spatial resolution

    NASA Astrophysics Data System (ADS)

    Heo, Yong-Ho; Ih, Jeong-Guon; Bodén, Hans

    2014-11-01

    Source identification of acoustic characteristics of in-duct fluid machinery is required for coping with the fluid-borne noise. By knowing the acoustic pressure and particle velocity field at the source plane in detail, the sound generation mechanism of a fluid machine can be understood. The identified spatial distribution of the strength of major radiators would be useful for the low noise design. Conventional methods for measuring the source in a wide duct have not been very helpful in investigating the source properties in detail because their spatial resolution is improper for the design purpose. In this work, an inverse method to estimate the source parameters with a high spatial resolution is studied. The theoretical formulation including the evanescent modes and near-field measurement data is given for a wide duct. After validating the proposed method to a duct excited by an acoustic driver, an experiment on a duct system driven by an air blower is conducted in the presence of flow. A convergence test for the evanescent modes is performed to find the necessary number of modes to regenerate the measured pressure field precisely. By using the converged modal amplitudes, very-close near-field pressure to the source is regenerated and compared with the measured pressure, and the maximum error was -16.3 dB. The source parameters are restored from the converged modal amplitudes. Then, the distribution of source parameters on the driver and the blower is clearly revealed with a high spatial resolution for kR<1.84 in which range only plane waves can propagate to far field in a duct. Measurement using a flush mounted sensor array is discussed, and the removal of pure radial modes in the modeling is suggested.

  14. Cold air systems: Sleeping giant

    SciTech Connect

    MacCracken, C.D. )

    1994-04-01

    This article describes how cold air systems help owners increase the profits from their buildings by reducing electric costs and improving indoor air quality through lower relative humidity levels. Cold air distribution involves energy savings, cost savings, space savings, greater comfort, cleaner air, thermal storage, tighter ducting, coil redesign, lower relative humidities, retrofitting, and improved indoor air quality (IAQ). It opens a door for architects, engineers, owners, builders, environmentalists, retrofitters, designers, occupants, and manufacturers. Three things have held up cold air's usage: multiple fan-powered boxes that ate up the energy savings of primary fans. Cold air room diffusers that provided inadequate comfort. Condensation from ducts, boxes, and diffusers. Such problems have been largely eliminated through research and development by utilities and manufacturers. New cold air diffusers no longer need fan powered boxes. It has also been found that condensation is not a concern so long as the ducts are located in air conditioned space, such as drop ceilings or central risers, where relative humidity falls quickly during morning startup.

  15. Lightning return stroke models

    NASA Technical Reports Server (NTRS)

    Lin, Y. T.; Uman, M. A.; Standler, R. B.

    1980-01-01

    We test the two most commonly used lightning return stroke models, Bruce-Golde and transmission line, against subsequent stroke electric and magnetic field wave forms measured simultaneously at near and distant stations and show that these models are inadequate to describe the experimental data. We then propose a new return stroke model that is physically plausible and that yields good approximations to the measured two-station fields. Using the new model, we derive return stroke charge and current statistics for about 100 subsequent strokes.

  16. The refractive propagation factor and the rough evaporation duct experiment

    NASA Astrophysics Data System (ADS)

    Doss-Hammel, Stephen M.; Tsintikidis, Dimitris; Davidson, Kenneth L.; Frederickson, Paul A.

    2003-03-01

    The Rough Evaporation Duct Experiment (RED) assessed the effects of the air-sea boundary layer on microwave and infrared (IR) signal propagation near the sea surface. The experiment was designed around the Floating Instrument Platform (FLIP) research platform, which was moored 10 kilometers off the northeast shore of Oahu, Hawaii. A 10-kilometer infrared propagation path was created from FLIP to a shore-based receiver and both scintillation and transmission measurements were made around the clock for a two-week period. An accurate model for the propagation of infrared signals in the marine atmospheric surface layer remains an elusive goal. Within the first tens of meters of elevation above the sea surface there are substantial vertical gradients of mass and temperature, and this has a strong effect on the prediction of extinction of the infrared signal. The effectiveness of the propagation models will be investigated and the results from the infrared signal propagation study during RED will be shown.

  17. Ducted Fan Designs Lead to Potential New Vehicles

    NASA Technical Reports Server (NTRS)

    2010-01-01

    In 1994, aerospace engineers Rob Bulaga and Mike Moshier formed Trek Aerospace Inc., based in Folsom, California, to develop personal air vehicles using a novel ducted fan design. The company relied on Ames Research Center for a great deal of testing, the results of which have provided greater lift, lowered weight, more power, and improved maneuverability. The technology has been applied to three models: the Dragonfly UMR-1, the Springtail EFV, and the OVIWUN, a small-scale version that is for sale through the company's Web site. It is safer than a manned vehicle, and its size makes it relatively difficult for it to damage itself during test flights the way a larger mass, faster craft could.

  18. Increased Expression of TGF-β Signaling Components in a Mouse Model of Fibrosis Induced by Submandibular Gland Duct Ligation

    PubMed Central

    Woods, Lucas T.; Camden, Jean M.; El-Sayed, Farid G.; Khalafalla, Mahmoud G.; Petris, Michael J.; Erb, Laurie; Weisman, Gary A.

    2015-01-01

    Transforming growth factor-β (TGF-β) is a multi-functional cytokine with a well-described role in the regulation of tissue fibrosis and regeneration in the liver, kidney and lung. Submandibular gland (SMG) duct ligation and subsequent deligation in rodents is a classical model for studying salivary gland damage and regeneration. While previous studies suggest that TGF-β may contribute to salivary gland fibrosis, the expression of TGF-β signaling components has not been investigated in relation to mouse SMG duct ligation-induced fibrosis and regeneration following ductal deligation. Following a 7 day SMG duct ligation, TGF-β1 and TGF-β3 were significantly upregulated in the SMG, as were TGF-β receptor 1 and downstream Smad family transcription factors in salivary acinar cells, but not in ductal cells. In acinar cells, duct ligation also led to upregulation of snail, a Smad-activated E-cadherin repressor and regulator of epithelial-mesenchymal transition, whereas in ductal cells upregulation of E-cadherin was observed while snail expression was unchanged. Upregulation of these TGF-β signaling components correlated with upregulation of fibrosis markers collagen 1 and fibronectin, responses that were inhibited by administration of the TGF-β receptor 1 inhibitors SB431542 or GW788388. After SMG regeneration following a 28 day duct deligation, TGF-β signaling components and epithelial-mesenchymal transition markers returned to levels similar to non-ligated controls. The results from this study indicate that increased TGF-β signaling contributes to duct ligation-induced changes in salivary epithelium that correlate with glandular fibrosis. Furthermore, the reversibility of enhanced TGF-β signaling in acinar cells of duct-ligated mouse SMG after deligation indicates that this is an ideal model for studying TGF-β signaling mechanisms in salivary epithelium as well as mechanisms of fibrosis initiation and their resolution. PMID:25955532

  19. Minimum airflow reset of single-duct VAV terminal boxes

    NASA Astrophysics Data System (ADS)

    Cho, Young-Hum

    Single duct Variable Air Volume (VAV) systems are currently the most widely used type of HVAC system in the United States. When installing such a system, it is critical to determine the minimum airflow set point of the terminal box, as an optimally selected set point will improve the level of thermal comfort and indoor air quality (IAQ) while at the same time lower overall energy costs. In principle, this minimum rate should be calculated according to the minimum ventilation requirement based on ASHRAE standard 62.1 and maximum heating load of the zone. Several factors must be carefully considered when calculating this minimum rate. Terminal boxes with conventional control sequences may result in occupant discomfort and energy waste. If the minimum rate of airflow is set too high, the AHUs will consume excess fan power, and the terminal boxes may cause significant simultaneous room heating and cooling. At the same time, a rate that is too low will result in poor air circulation and indoor air quality in the air-conditioned space. Currently, many scholars are investigating how to change the algorithm of the advanced VAV terminal box controller without retrofitting. Some of these controllers have been found to effectively improve thermal comfort, indoor air quality, and energy efficiency. However, minimum airflow set points have not yet been identified, nor has controller performance been verified in confirmed studies. In this study, control algorithms were developed that automatically identify and reset terminal box minimum airflow set points, thereby improving indoor air quality and thermal comfort levels, and reducing the overall rate of energy consumption. A theoretical analysis of the optimal minimum airflow and discharge air temperature was performed to identify the potential energy benefits of resetting the terminal box minimum airflow set points. Applicable control algorithms for calculating the ideal values for the minimum airflow reset were developed and

  20. Numerical Simulation of Noise from Supersonic Jets Passing Through a Rigid Duct

    NASA Technical Reports Server (NTRS)

    Kandula, Max

    2012-01-01

    The generation, propagation and radiation of sound from a perfectly expanded Mach 2.5 cold supersonic jet flowing through an enclosed rigid-walled duct with an upstream J-deflector have been numerically simulated with the aid of OVERFLOW Navier-Stokes CFD code. A one-equation turbulence model is considered. While the near-field sound sources are computed by the CFD code, the far-field sound is evaluated by Kirchhoff surface integral formulation. Predictions of the farfield directivity of the OASPL (Overall Sound Pressure Level) agree satisfactorily with the experimental data previously reported by the author. Calculations also suggest that there is significant entrainment of air into the duct, with the mass flow rate of entrained air being about three times the jet exit mass flow rate.

  1. Will Duct Tape and Plastic Really Work? Issues Related to Expedient Shelter-In-Place

    SciTech Connect

    Sorensen, J.H.

    2002-08-30

    Expedient sheltering involves the use of common materials to enhance the safety of a room inside a building against the impacts of a chemical plume. The central premise behind taping and sealing with duct tape and plastic is to reduce airflow into a room. This paper reviews issues associated with the use of expedient sheltering materials and the effectiveness of this strategy. Expedient sheltering provides additional protection to people sheltering in place beyond that provided by the house and by a safe room without expedient measures. The materials chosen for taping and sealing--duct tape and plastic--are appropriate because they effectively reduce infiltration and the materials should withstand a vapor challenge. Taping is essential to reduce air infiltration. Plastic sheeting is not a critical element for reducing air infiltration, but it makes sealing off large windows easier.

  2. Thyroglossal Duct Carcinoma in a Cat.

    PubMed

    Moorer, Jeremiah D; Breshears, Melanie A; Dugat, Danielle R

    2016-01-01

    A 14 yr old castrated domestic shorthair cat presented for a fluid-filled structure in the ventral cervical region that had been present for 1 yr and had not resolved after repeated aspiration and drainage. Cervical computed tomography showed an approximately 10 cm, fluid-filled, multilobulated mass located on the ventrolateral right side of the cervical region extending into the thoracic inlet. Cytologic examination of the fluid revealed cystic fluid with evidence of chronic hemorrhage. The mass was surgically removed, and histopathologic examination revealed a thyroglossal duct carcinoma. Thyroid and parathyroid gland origin were ruled out by negative immunohistochemical staining for thyroglobulin, parathyroid hormone, calcitonin, and synaptophysin. No adjunctive treatment was performed and no recurrence was noted at 14 mo. Thyroglossal duct carcinoma has not been previously reported in a cat. There are two previous reports of squamous cell carcinoma of the thyroglossal duct in dogs. In humans, with complete removal and no evidence of metastasis, carcinoma of the thyroglossal duct has a good prognosis for recovery. PMID:27259027

  3. Idea Bank: Duct Tape Note Twister

    ERIC Educational Resources Information Center

    McHenry, Molly

    2008-01-01

    In this article, the author relates how she observed a middle school math teacher deliver a miserable class. She realized that she did the same thing to her music students. To engage her students, she developed "Note Twister," a music reading game using duct tape to form musical notes and the basic premise behind the game, "Twister." She finds…

  4. Starting flow in regular polygonal ducts

    NASA Astrophysics Data System (ADS)

    Wang, C. Y.

    2016-06-01

    The starting flows in regular polygonal ducts of S = 3, 4, 5, 6, 8 sides are determined by the method of eigenfunction superposition. The necessary S-fold symmetric eigenfunctions and eigenvalues of the Helmholtz equation are found either exactly or by boundary point match. The results show the starting time is governed by the first eigenvalue.

  5. Thoracoscopic Ligation of the Thoracic Duct

    PubMed Central

    Teixeira, Julio A.

    2000-01-01

    Objective: When nonoperative treatment of chylothorax fails, thoracic duct ligation is usually performed through a thoracotomy. We describe two cases of persistent chylothorax, in a child and an adult, successfully treated with thoracoscopic ligation of the thoracic duct. Methods: A 4-year-old girl developed a right chylothorax following a Fontan procedure. Aggressive nonoperative management failed to eliminate the persistent chyle loss. A 72-year-old insulin-dependent diabetic man was involved in a motor vehicle accident, in which he sustained multiple fractured ribs, a right hemopneumothorax, a right femoral shaft fracture, and a T-11 thoracic vertebral fracture. Subsequently, he developed a right chylothorax, which did not respond to nonoperative management. Both patients were successfully treated with thoracoscopic ligation of the thoracic duct. Results: The child had significant decrease of chyle drainage following surgery. Increased drainage that appeared after the introduction of full feedings five days postoperatively was controlled with the somatostatin analog octreotide. The chest tube was removed two weeks after surgery. After two years' follow-up, she has had no recurrence of chylothorax. The adult had no chyle drainage following surgery. He was maintained on a medium-chain triglyceride diet postoperatively for two weeks. The chest tube was removed four days after surgery. After six months' follow-up, he has had no recurrence of chylothorax. Conclusions: Thoracoscopic ligation of the thoracic duct provides a safe and effective treatment of chylothorax and may avoid thoracotomy and its associated morbidity. PMID:10987402

  6. 46 CFR 116.610 - Ventilation ducts.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... prevent corrosion; (4) Fire dampers must be capable of manual operation from outside the space served, be... damper, automatic damper, or vent cover, must be provided in an accessible location outside the space... duct penetrating an A-Class fire control boundary and opening into a space formed by that boundary...

  7. 46 CFR 116.610 - Ventilation ducts.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... prevent corrosion; (4) Fire dampers must be capable of manual operation from outside the space served, be... damper, automatic damper, or vent cover, must be provided in an accessible location outside the space... duct penetrating an A-Class fire control boundary and opening into a space formed by that boundary...

  8. Sound attenuation of fiberglass lined ventilation ducts

    NASA Astrophysics Data System (ADS)

    Albright, Jacob

    Sound attenuation is a crucial part of designing any HVAC system. Most ventilation systems are designed to be in areas occupied by one or more persons. If these systems do not adequately attenuate the sound of the supply fan, compressor, or any other source of sound, the affected area could be subject to an array of problems ranging from an annoying hum to a deafening howl. The goals of this project are to quantify the sound attenuation properties of fiberglass duct liner and to perform a regression analysis to develop equations to predict insertion loss values for both rectangular and round duct liners. The first goal was accomplished via insertion loss testing. The tests performed conformed to the ASTM E477 standard. Using the insertion loss test data, regression equations were developed to predict insertion loss values for rectangular ducts ranging in size from 12-in x 18-in to 48-in x 48-in in lengths ranging from 3ft to 30ft. Regression equations were also developed to predict insertion loss values for round ducts ranging in diameters from 12-in to 48-in in lengths ranging from 3ft to 30ft.

  9. The Energy Implications of Air-Side Fouling in Constant Air Volume HVAC Systems

    NASA Astrophysics Data System (ADS)

    Wilson, Eric J. H.

    2011-12-01

    This thesis examines the effect of air-side fouling on the energy consumption of constant air volume (CAV) heating, ventilating, and air conditioning (HVAC) systems in residential and small commercial buildings. There is a particular focus on evaluating the potential energy savings that may result from the remediation of such fouling from coils, filters, and other air system components. A computer model was constructed to simulate the behavior of a building and its duct system under various levels of fouling. The model was verified through laboratory and field testing and then used to run parametric simulations to examine the range of energy impacts for various climates and duct system characteristics. A sensitivity analysis was conducted to determine the impact of parameters like duct insulation, duct leakage, duct location, and duct design on savings potential. Duct system pressures, temperatures, and energy consumption for two houses were monitored for one month. The houses' duct systems, which were both in conditioned space, were given a full cleaning, and were then monitored for another month. The flow rates at the houses improved by 10% and 6%. The improvements were primarily due to installing a new filter, as both houses had only light coil fouling. The results indicate that there was negligible change in heating energy efficiency due to the system cleaning. The parametric simulation results are in agreement with the field experiment: for systems in all eight climates, with flowrates degraded by 20% or less, if ducts are located within the thermal zone, HVAC source energy savings from cleaning are negligible or even slightly negative. However, if ducts are outside the thermal zone, savings are in the 1 to 5% range. For systems with flowrates degraded by 40%, if ducts are within the thermal zone, savings from cleaning occurs only for air conditioning energy, up to 8% in climates like Miami, FL. If ducts are outside the thermal zone, savings occurs with both

  10. Turbofan aft duct suppressor study program listing and user's guide

    NASA Technical Reports Server (NTRS)

    Joshi, M. C.; Kraft, R. E.

    1983-01-01

    A description of the structure of the Annular Flow Duct Program (AFDP) for the calculation of acoustic suppression due to treatment in a finite length annular duct carrying sheared flow is presented. Although most appropriate for engine exhaust ducts, this program can be used to study sound propagation in any duct that maintains annular geometry over a considerable length of the duct. The program is based on the modal analysis of sound propagation in ducts with axial segments of different wall impedances. For specified duct geometry, wall impedance, flow and acoustic conditions in the duct (including mode amplitude distribution of the source) and duct termination reflection characteristics, the program calculates the suppression due to the treatment in the duct. The presence of forward and backward traveling modes in the duct due to the reflection and redistribution of modes at segment interfaces and duct end terminations are taken into account in the calculations. The effects of thin wall boundary layers (with a linear or mean flow velocity profile) on the acoustic propagation are also included in the program. A functional description of the major subroutines is included and a sample run is provided with an explanation of the output.

  11. A bidirectional microphone for the measurement of duct noise

    NASA Astrophysics Data System (ADS)

    La Fontaine, R. F.; Shepherd, I. C.; Cabelli, A.

    1985-08-01

    A bidirectional microphone which resolves acoustic plane waves in ducts into forward and backward propagating components is described. The microphone has a flat frequency response and finds applications in the analysis of duct noise and in the determination of reflection coefficients for various duct configurations. It can also be employed as a unidirectional microphone in active noise attenuators.

  12. Return to Bangka Island.

    PubMed

    Spence, J

    2001-07-01

    This article is a return in a couple of ways to one of the most tragic events in the history of Australian military nursing. Firstly, it describes how the evacuation of nurses from Singapore in 1941 led to circumstances that resulted in the massacre or internment of many of those women. Then in 1993, a group of surviving World War II nurses and current serving Australian Army nurses returned to the site of their sorrow. PMID:15129536

  13. Aerosol sampling from stacks and ducts at the Rocky Flats Plant

    SciTech Connect

    McFarlane, A.R.; Anand, N.K.; Ortiz, C.A.

    1995-12-31

    While the Rocky Flats Plant (RFP) in Golden, CO is being decommissioned; there is air flow through the ventilation systems in the buildings. Although the air is HEPA filtered, under the requirements of both the U.S. EPA and the U.S. DOE, several of the stacks and ducts must be continuously monitored for radionuclide aerosol particles, where plutonium is the principal radionuclide of concern. The air sampling effort for compliance with EPA requirements is focussed on the acquisition of representative aerosol samples, which are collected on filters and subsequently analyzed in a laboratory. The goal of the DOE sampling is to acquire representative samples that can be analyzed with near-real-time monitors for alarming purposes, where the alarms are used to warn workers that may be affected by elevated concentrations of radionuclides. The air sampling at RFP is based on single point representative sampling with a shrouded probe. For stacks and ducts that are under the cognizance of EPA, the approach is embodied in a set of Alternate Reference Methodologies that EPA has approved for use at DOE facilities. Shrouded probes were designed based on numerical predictions of performance and the efficacy of the probes was verified by wind tunnel tests. Aerosol transport lines were designed using a code, DEPOSITION that provides optimization of aerosol penetration. Adequacy of a location for single point sampling was based on numerical criteria for mixing of both contaminant mass and fluid momentum as manifested by the uniformity of the velocity profile and the profiles of tracer gas and aerosol particles. Scale models were constructed of key ducts and these were tested in the laboratory to determine the proper locations. For ducts and stacks that fall under DOE, but not EPA requirements, similar methodology was used; however, the single point sampling location is based on alarming considerations.

  14. Studies in short haul air transportation in the California corridor: Effects of design runway length; community acceptance; impact of return on investment and fuel cost increases. Volume 2: Appendices

    NASA Technical Reports Server (NTRS)

    Shevell, R. S.; Jones, D. W., Jr.

    1973-01-01

    The development of a forecast model for short haul air transportation systems in the California Corridor is discussed. The factors which determine the level of air traffic demand are identified. A forecast equation for use in airport utilization analysis is developed. A mathematical model is submitted to show the relationship between population, employment, and income for indicating future air transportation utilization. Diagrams and tables of data are included to support the conclusions reached regarding air transportation economic factors.

  15. Basement utility room (room 24; air handling room), near the ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Basement utility room (room 24; air handling room), near the west end of the combat operations center, looking southwest towards fan system one, air ducts, and walk-in filter rooms. The exterior equipment well is visible at the left - March Air Force Base, Strategic Air Command, Combat Operations Center, 5220 Riverside Drive, Moreno Valley, Riverside County, CA

  16. Duct injection for SO{sub 2} control, Design Handbook, Volume 1, Process design and engineering guidelines

    SciTech Connect

    1995-09-01

    PETC developed a comprehensive program of coal-related, acid-rain research and development with a major activity area centering on flue gas cleanup and control of SO{sub 2} emissions. Particular emphasis was placed on the retrofit measures for older coal-fired power plants which predate the 1971 New Source Performance Standards. Candidate emission control technologies fall into three categories, depending upon their point of application along the fuel path (i.e., pre, during, or post combustion). The post-combustion, in-duct injection of a calcium-based chemical reagent seemed promising. Preliminary studies showed that reagent injection between the existing air heater and electrostatic precipitator (ESP) could remove between 50-60% of the SO{sub 2} and produce an environmentally safe, dry, solid waste that is easily disposed. Although SO{sub 2} removal efficiencies were less, the estimated capital costs for duct injection technology were low making the economics of duct injection systems seem favorable when compared to conventional wet slurry scrubbers under certain circumstances. With the promulgation of the Clean Air Act Amendments of 1990 came more incentive for the development of low capital cost flue gas desulfurization (FGD) processes. A number of technical problems had to be resolved, however, before duct injection technology could be brought to a state of commercial readiness. The Duct Injection Technology Development Program was launched as a comprehensive, four-year research effort undertaken by PETC to develop this new technology. Completed in 1992, this Duct Injection Design Handbook and the three-dimensional predictive mathematical model constitute two primary end products from this development program. The aim of this design handbook and the accompanying math model is to provide utility personnel with sufficient information to evaluate duct injection technology against competing SO{sub 2} emissions reduction strategies for an existing plant.

  17. Thermal environmental case study of an existing underfloor air distribution (UFAD) system in a high-rise building in the tropics

    NASA Astrophysics Data System (ADS)

    Ya, Y. H.; Poh, K. S.

    2015-09-01

    The performance of an existing underfloor air distribution (UFAD) system in a renowned high-rise office tower in Malaysia was studied to identify the root cause issues behind the poor indoor air quality. Occupants are the best thermal sensor. The building was detected with the sick building syndrome (SBS) that causes runny noses, flu-like symptoms, irritated skin, and etc. Long period of exposure to indoor air pollutants may increase the occupant's health risk. The parameters such as the space temperature, relative humidity, air movement, air change, fresh air flow rate, chilled water supply and return are evaluated at three stories that consist of five open offices. A full traverse study was carried out at one of the fresh air duct. A simplified duct flow measurement method using pitot-tubes was developed. The results showed that the diffusers were not effective in creating the swirl effect to the space. Internal heat gain from human and office electrical equipment were not drawn out effectively. Besides, relative humidity has exceeded the recommended level. These issues were caused by the poor maintenance of the building. The energy efficiency strategy of the UFAD system comes from the higher supply air temperature. It may leads to insufficient cooling load for the latent heat gained under improper system performance. Special care and considerations in design, construction and maintenance are needed to ensure the indoor air quality to be maintained. Several improvements were recommended to tackle the existing indoor air quality issues. Solar system was studied as one of the innovative method for retrofitting.

  18. Experimental testing and computational modeling of flat oval duct deflection

    SciTech Connect

    Smolinski, P.J.; Palmer, G.S.

    1998-10-01

    The deflection characteristics of spiral seam flat oval HVAC duct are examined in this study, and the effects of duct size, wall thickness, and the size spacing, and type of external reinforcement on the duct deformation are investigated. A duct test setup and a deflection measurement frame were developed for measuring the deformation of flat oval duct, and experimental testing was performed on a variety of duct configurations to measure the duct deflections at various positive and negative internal pressures. Finite element computer models of the ducts were developed to predict the deflections. The correlation between the predictions of the computer model and the data from the experimental testing is highly variable with differences ranging from a few percent to several hundred percent. In general, it was found that there was closer agreement between the finite element results and the experimental measurements for smaller duct and at locations of type 2 external reinforcements. This may be due to the fact that the finite element model assumed the idealized flat oval shape and this shape was better matched by smaller ducts and near the external reinforcement. It was also found that in some cases, unreinforced duct could achieve higher pressures than type 1 reinforced duct before exceeding the deflection limits. Sources of error include the uneven surface of the mastic in the measurement of the duct joint deflection and the variance of the actual duct shape from the idealized shape used in the finite element model. This study did not examine the variability of the experimental results due to differences in duct shape or manufacture.

  19. Investigation of the Rocket Induced Flow Field in a Rectangular Duct

    NASA Technical Reports Server (NTRS)

    Landrum, D. Brian; Lambert, James; Thames, Mignon; Hawk, Clark

    1999-01-01

    Rocket-Based Combined Cycle (RBCC) concepts attempt to improve the performance of launch vehicles at all points in the launch trajectory and make highly reusable launch vehicles a reality. The Aerojet Strutjet RBCC concept consists of a variable geometry duct with internal, vertical struts that functions in ducted rocket, ramjet, scramjet, and pure rocket modes. These struts have rocket and turbine exhaust nozzles imbedded within them. The rocket flows create an ejector effect with the ingested air at subsonic flight velocities. In ramjet and scramjet modes, the fuel rich nozzle flows react with the ingested air producing an afterburner effect. Under a NASA Marshall Space Flight Center contract, the UAH Propulsion Research Center (PRC) has designed and built a Strutjet simulation facility. A scale model of a single strut has been built and is undergoing cold-flow testing to investigate the mixing of the rocket and turbine exhausts with the ingested air. A complementary experimental program is also underway to examine the induced flow-field generated by rocket nozzles confined in a rectangular duct. Characterizing the induced flow behavior is critical to understanding and optimizing the performance of future Strutjet-based RBCC propulsion systems. The proposed paper will present results from the rocket induced flow investigation.

  20. Performance Study and CFD Predictions of a Ducted Fan System

    NASA Technical Reports Server (NTRS)

    Abrego, Anita I.; Chang, I-Chung; Bulaga, Robert W.; Rutkowski, Michael (Technical Monitor)

    2002-01-01

    An experimental investigation was completed in the NASA Ames 7 by 10-Foot Wind Tunnel to study the performance characteristics of a ducted fan. The goal of this effort is to study the effect of ducted fan geometry and utilize Computational Fluid Dynamics (CFD) analysis to provide a baseline for correlation. A 38-inch diameter, 10-inch chord duct with a five-bladed fixed-pitch fan was tested. Duct performance data were obtained in hover, vertical climb, and forward flight test conditions. This paper will present a description of the test, duct performance results and correlation with CFD predictions.

  1. Transition duct with divided upstream and downstream portions

    SciTech Connect

    McMahan, Kevin Weston; LeBegue, Jeffrey Scott; Maldonado, Jaime Javier; Dillard, Daniel Jackson; Flanagan, James Scott

    2015-07-14

    Turbine systems are provided. In one embodiment, a turbine system includes a transition duct comprising an inlet, an outlet, and a duct passage extending between the inlet and the outlet and defining a longitudinal axis, a radial axis, and a tangential axis. The outlet of the transition duct is offset from the inlet along the longitudinal axis and the tangential axis. The duct passage includes an upstream portion extending from the inlet and a downstream portion extending from the outlet. The turbine system further includes a rib extending from an outer surface of the duct passage, the rib dividing the upstream portion and the downstream portion.

  2. Acoustic radiation from lined, unflanged ducts: Acoustic source distribution program

    NASA Technical Reports Server (NTRS)

    Beckemeyer, R. J.; Sawdy, D. T.

    1971-01-01

    An acoustic radiation analysis was developed to predict the far-field characteristics of fan noise radiated from an acoustically lined unflanged duct. This analysis is comprised of three modular digital computer programs which together provide a capability of accounting for the impedance mismatch at the duct exit plane. Admissible duct configurations include circular or annular, with or without an extended centerbody. This variation in duct configurations provides a capability of modeling inlet and fan duct noise radiation. The computer programs are described in detail.

  3. Investigation Flow Uniformity in a Supersonic Duct with High Enthalpy Flows

    NASA Technical Reports Server (NTRS)

    Balboni, John; Atler, Doug; Gokcen, Tahir; Hartman, G. Joseph (Technical Monitor)

    1995-01-01

    Flow uniformity in a high enthalpy facility is investigated. The scramjet research facility is composed of a rectangular combustor duct connected to a 100 MW electric arc air heater. The Mach 3.3 flow is accelerated through a two-dimensional contoured nozzle. Instream measurements were made with water-cooled Pitot probes and stagnation point heat flux gages at stream enthalpy levels ranging from 4 to 7 Mj/kg. Flow surveys were made on the flow centerline and off centerline in order to measure the three dimensional uniformity of the flow in the rectangular duct. Measurements indicated that although the flow in the aspect ratio 6:1 duct was relatively uniform on the centerline, three dimensional viscous effects were apparent near the corners. Flow through the nozzle and constant area duct was modeled computationally using a two dimensional, Navier-Stokes, reacting gas code. The computations predict that the flow in the test section is in vibrational equilibrium. The computed and measured Pitot pressure and heat flux profiles are in reasonable agreement with the experimental data.

  4. Coupled parametric design of flow control and duct shape

    NASA Technical Reports Server (NTRS)

    Florea, Razvan (Inventor); Bertuccioli, Luca (Inventor)

    2009-01-01

    A method for designing gas turbine engine components using a coupled parametric analysis of part geometry and flow control is disclosed. Included are the steps of parametrically defining the geometry of the duct wall shape, parametrically defining one or more flow control actuators in the duct wall, measuring a plurality of performance parameters or metrics (e.g., flow characteristics) of the duct and comparing the results of the measurement with desired or target parameters, and selecting the optimal duct geometry and flow control for at least a portion of the duct, the selection process including evaluating the plurality of performance metrics in a pareto analysis. The use of this method in the design of inter-turbine transition ducts, serpentine ducts, inlets, diffusers, and similar components provides a design which reduces pressure losses and flow profile distortions.

  5. Curved Duct Noise Prediction Using the Fast Scattering Code

    NASA Technical Reports Server (NTRS)

    Dunn, M. H.; Tinetti, Ana F.; Farassat, F.

    2007-01-01

    Results of a study to validate the Fast Scattering Code (FSC) as a duct noise predictor, including the effects of curvature, finite impedance on the walls, and uniform background flow, are presented in this paper. Infinite duct theory was used to generate the modal content of the sound propagating within the duct. Liner effects were incorporated via a sound absorbing boundary condition on the scattering surfaces. Simulations for a rectangular duct of constant cross-sectional area have been compared to analytical solutions and experimental data. Comparisons with analytical results indicate that the code can properly calculate a given dominant mode for hardwall surfaces. Simulated acoustic behavior in the presence of lined walls (using hardwall duct modes as incident sound) is consistent with expected trends. Duct curvature was found to enhance weaker modes and reduce pressure amplitude. Agreement between simulated and experimental results for a straight duct with hard walls (no flow) was excellent.

  6. Study on numerical simulation of flowfield in afterburner for ducted rocket

    NASA Astrophysics Data System (ADS)

    Ding, Xiaoyu; Jin, Xing; Zhang, Peng

    2015-03-01

    Ducted rocket has been widely concerned on account of its high specific impulse, combustion stability and convenient maintenance which mixes the exhaust from a fuel gas generator with air from air inlet, and burns to produce thrust. It is necessary to establish two-dimensional or three-dimensional numerical models based on computational fluid dynamics to study on the flowfield in afterburner which is the key of ducted rocket because of expensive experiments, which is aimed at providing theoretical foundation for ducted rocket's development. In this paper, the gas-phase turbulent combustion process in afterburner with dual inlet three-dimensional mode was simulated numerically by solving Favre-averaged compressible turbulent N-S equations, the renormalization group (RNG) k-ɛ turbulence model was applied to simulate the turbulent flow, and Eddy-Dissipation Model (EDM) was applied to simulate gas combustion. Through simulation, situation analysis of flowfield in afterburner was done, and the influence of mixing combustion on afterburner was studied by taking air inlet angles and air-fuel ratio into account respectively. The results indicate that the distribution of temperature in afterburner is nonuniform, the backflow and axial swirl produced by gas mixing have an important influence on afterburner combustion. As air inlet angle is increased, the intensity of gas mixing is enhanced which is beneficial for afterburner combustion. That increasing air-fuel ratio is able to strength contact of oxygen with fuel gas, so that more fuel gas is consumed in the same location which is more beneficial for afterburner combustion.

  7. Hydrogen-air ignition torch

    NASA Technical Reports Server (NTRS)

    Repas, G. A.

    1986-01-01

    The design and operation of a hydrogen-air ignition torch presently being used to burn off excess hydrogen that accumulates in the scrubber exhaust ducts of two rocket engine test facilities at the NASA Lewis Research Center in Cleveland, Ohio, is described.

  8. Optimization of the mechanical performance of a two-duct semicircular duct system--part 2: excitation of endolymph movements.

    PubMed

    Muller, M; Verhagen, J H G

    2002-06-21

    The endolymph flow inside the semicircular ducts is analytically investigated by considering a system of two hydrodynamically interconnected ducts. Rotation of this system adds an amount of motion (momentum) to parts of it. This results in an endolymph flow in generally all vestibular parts. The "external impulses" are the impulses which emerge by rotation of exclusively a particular vestibular part. The real impulses can be calculated from a set of equations which contain the external impulses. Analytical expressions are derived for the initial velocities in the ducts and for the maximum endolymph displacements. These formulae contain the external impulses and the ratios of: (1) the radii of crus commune and ducts (gamma), (2) the lengths of crus commune and ducts (lambda). It was proven that an interconnected system composed of two ducts, and also a system composed of two such semicircular duct systems, behaves as a pure rotation transducer (like a single duct does), also when it is rotated excentrically. Duct systems with polygonal and circular geometries were used to evaluate whether an optimal value of lambda would exist (gamma was already considered elsewhere). Optimum values of lambda in a range of about 0.10-0.52 were found. This rather wide range of values agrees with values from measurements. Optimization of an interconnected duct system appeared to be equal to optimization of a system composed of separate ducts. PMID:12151259

  9. Contrasting the efficiency of radiation belt losses caused by ducted and non-ducted whistler mode waves from manmade transmitters

    NASA Astrophysics Data System (ADS)

    Rodger, C. J.; Carson, Bonar; Cummer, Steven A.; Gamble, R. J.; Clilverd, Mark; Sauvaud, Jean-Andre; Parrot, Michel; Green, Janet

    Electromagnetic waves in the VLF range generated at or near the Earth's surface can penetrate the ionosphere and propagate through the plasmasphere. It has long been recognized that whistler-mode waves can be trapped in localized field-aligned enhancements in plasmaspheric ionization density termed "whistler ducts", which guide the waves from one hemisphere to the other. For the non-guided cases, the whistler mode waves are said to be "nonducted". The nature of wave-particle interactions are affected by the wave being ducted or non-ducted through influence on the wave-normal angles. In the field-aligned ducted case, the dominant resonance possible is first-order cyclotron, whereas non-ducted interactions open up a much wider range of energies through equatorial and off-equatorial gyro-resonance. Thus the significance of these VLF waves as drivers of radiation belt losses is strongly influenced by whether these waves are dominantly ducted or non-ducted. At this point there is conflicting information in the literature as to whether the most significant loss processes are driven by ducted or non-ducted waves. In this study we use loss cone observations from instruments onboard the DEMETER and POES low-altitude satellites to focus on losses driven by powerful VLF communications transmitters. We wish to better characterise the losses previously reported and explained through interactions with ducted VLF transmissions. We also plan to examine losses into the atmosphere driven by non-ducted transmissions.

  10. Theoretical analysis of HVAC duct hanger systems

    NASA Technical Reports Server (NTRS)

    Miller, R. D.

    1987-01-01

    Several methods are presented which, together, may be used in the analysis of duct hanger systems over a wide range of frequencies. The finite element method (FEM) and component mode synthesis (CMS) method are used for low- to mid-frequency range computations and have been shown to yield reasonably close results. The statistical energy analysis (SEA) method yields predictions which agree with the CMS results for the 800 to 1000 Hz range provided that a sufficient number of modes participate. The CMS approach has been shown to yield valuable insight into the mid-frequency range of the analysis. It has been demonstrated that it is possible to conduct an analysis of a duct/hanger system in a cost-effective way for a wide frequency range, using several methods which overlap for several frequency bands.

  11. Porokeratotic Eccrine Ostial and Dermal Duct Nevus

    PubMed Central

    Naraghi, Mona Masoumeh; Goodarzi, Azadeh

    2013-01-01

    PEODDN is a rare benign cutaneous disorder that clinically resembles comedo nevus but favors the palms and soles, where pilosebaceous follicles are absent. Widespread involvement along Blaschko's lines can also occur. It is a disorder of keratinization involving the intraepidermal eccrine duct (acrosyringium) and is characterized by eccrine hamartoma and cornoid lamellation in pathology. The patient is a 29-year-old man with an 8-year history of pruritic skin lesions on his right lateral ankle. In the pathologic examination, multiple small epidermal invagination with overlying parakeratotic cornoid lamellation, loss of granular layer, and few dyskeratotic cells at the base of epidermal invagination are revealed. After clinic-pathologic correlation, the diagnosis of porokeratotic eccrine ostial and dermal duct nevus (PEODDN) was made. Late-onset and rare clinical presentation as pruritic lesion are the characteristic features that make this patient an extraordinary presentation of PEODDN. PMID:24307955

  12. Sea echo in tropospheric ducting environments

    NASA Astrophysics Data System (ADS)

    Pappert, R. A.; Paulus, R. A.; Tappert, F. D.

    1992-04-01

    Path loss formulas for sea surface backscatter are developed for horizontally stratified tropospheric ducting environments. First-order Bragg backscatter results coupled with ray and waveguide formalism serve as the basis for the development. Two features of composite model formalism, namely shadowing and tilting of the surface normal in the plane of incidence, are included in the development. Though developed for hh polarization, conventional composite model modifications for vertical polarization and depolarization can be incorporated into the echo models. Comparisons are made with previously generated parabolic equation results and with empirical model results generated by Engineers Refractive Effects Prediction System. These comparisons are for a frequency of 9.6 GHz for the standard atmosphere and for 14- and 28-m evaporation ducts. Results apply to wind speeds of 10, 20, 30, and 40 knots (about 5, 10, 15, and 20 m/s).

  13. Evaporation duct assessment from meteorological buoys

    NASA Astrophysics Data System (ADS)

    Hitney, Herbert V.

    2002-07-01

    The evaporation duct over the sea is usually assessed using bulk meteorological measurements. This paper investigates the utility of meteorological buoys as a source for these bulk measurements and compares evaporation duct assessments using two buoys in southern California waters separated by 128 km. A simple radio propagation experiment at 2.4 GHz between one of the buoys and the coast on an 18.2 km path is described. Observed propagation loss from this experiment is compared to modeled loss based on the meteorological measurements at each buoy. The purpose of this paper is to investigate radio propagation effects using established and accepted methods already described in the literature. Accordingly, no discussion of atmospheric surface layer meteorology affecting radio propagation is given.

  14. Low frequency sound attenuation in a flow duct using a thin slow sound material.

    PubMed

    Aurégan, Yves; Farooqui, Maaz; Groby, Jean-Philippe

    2016-05-01

    A thin subwavelength material that can be flush mounted in a duct and that gives an attenuation band at low frequencies in air flow channels is presented. To decrease the material thickness, the sound is slowed in the material using folded side branch tubes. The impedance of the material is compared to the optimal value given by the Cremer condition, which can differ greatly from the air characteristic impedance. Grazing flow on this material increases the losses at the interface between the flow and the material. PMID:27250200

  15. Ontogeny of the nasopalatine duct in primates.

    PubMed

    Shimp, Kristin L; Bhatnagar, Kunwar P; Bonar, Christopher J; Smith, Timothy D

    2003-09-01

    Ecological explanations have been put forward to account for the precocious or delayed development of patency in ducts leading to the vomeronasal organ (VNO) in certain mammals. Perinatal function may be related, in part, to the patency or fusion of the vomeronasal and nasopalatine (NPD) ducts. However, few studies have focused on NPD development in primates, which generally have a prolonged period of dependence during infancy. In this study we examined 24 prenatal primates and 13 neonatal primates, and a comparative sample of fetal mice and insectivores. In embryonic and early fetal Microcebus murinus, the NPD was completely fused, whereas in fetuses of later stages the duct was partially fused or completely patent. M. myoxinus of all stages demonstrated some degree of NPD fusion. In all other prenatal primates, the NPD was fused to some extent. Four prenatal insectivores (Tenrec ecaudatus) showed some degree of NPD fusion. In Mus musculus at 19 days gestation, the NPD was patent, although the anatomically separate VNO duct was fused. T. ecaudatus and most of the neonatal primates revealed complete NPD patency. An exception was Saguinus geoffroyi, which exhibited fusion of the NPD near the VNO opening. These observations may relate to differences in perinatal VNO function. The differences noted in our study suggest that M. murinus and M. myoxinus may differ in perinatal VNO functionality and perhaps in related behavior. Observations of neonatal primates suggest that NPD patency may be relatively common at birth and could serve other purposes in addition to being an access route for VNO stimuli. PMID:12923897

  16. Acoustic-Liner Admittance in a Duct

    NASA Technical Reports Server (NTRS)

    Watson, W. R.

    1986-01-01

    Method calculates admittance from easily obtainable values. New method for calculating acoustic-liner admittance in rectangular duct with grazing flow based on finite-element discretization of acoustic field and reposing of unknown admittance value as linear eigenvalue problem on admittance value. Problem solved by Gaussian elimination. Unlike existing methods, present method extendable to mean flows with two-dimensional boundary layers as well. In presence of shear, results of method compared well with results of Runge-Kutta integration technique.

  17. Zero leakage separable and semipermanent ducting joints

    NASA Technical Reports Server (NTRS)

    Mischel, H. T.

    1973-01-01

    A study program has been conducted to explore new methods of achieving zero leakage, separable and semipermanent, ducting joints for space flight vehicles. The study consisted of a search of literature of existing zero leakage methods, the generation of concepts of new methods of achieving the desired zero leakage criteria and the development of detailed analysis and design of a selected concept. Other techniques of leak detection were explored with a view toward improving this area.

  18. [Fever in returning travelers].

    PubMed

    Burchard, G

    2014-03-01

    Travel-related illness is most often due to gastrointestinal, febrile, and dermatologic diseases. Fever in a returned traveler demands prompt attention because it may be a manifestation of an infection that could be rapidly progressive and lethal. The approach to the febrile patient should be stepwise and consider travel and exposure history. Malaria is the most common cause of fever in patients returning from Sub-Saharan Africa, whereas dengue is more frequent in travelers from other tropical and subtropical areas. Other serious diseases are typhoid and paratyphoid fever, amebic liver abscess, visceral leishmaniasis, leptospirosis and-rarely-viral hemorrhagic fevers. PMID:24557143

  19. Electrostatic Return of Contaminants

    NASA Technical Reports Server (NTRS)

    Rantanen, R.; Gordon, T.

    2003-01-01

    A Model has been developed capable of calculating the electrostatic return of spacecraft-emitted molecules that are ionized and attracted back to the spacecraft by the spacecraft electric potential on its surfaces. The return of ionized contaminant molecules to charged spacecraft surfaces is very important to all altitudes. It is especially important at geosynchronous and interplanetary environments, since it may be the only mechanism by which contaminants can degrade a surface. This model is applicable to all altitudes and spacecraft geometries. In addition to results of the model will be completed to cover a wide range of potential space systems.

  20. A duct mapping method using least squares support vector machines

    NASA Astrophysics Data System (ADS)

    Douvenot, RéMi; Fabbro, Vincent; Gerstoft, Peter; Bourlier, Christophe; Saillard, Joseph

    2008-12-01

    This paper introduces a "refractivity from clutter" (RFC) approach with an inversion method based on a pregenerated database. The RFC method exploits the information contained in the radar sea clutter return to estimate the refractive index profile. Whereas initial efforts are based on algorithms giving a good accuracy involving high computational needs, the present method is based on a learning machine algorithm in order to obtain a real-time system. This paper shows the feasibility of a RFC technique based on the least squares support vector machine inversion method by comparing it to a genetic algorithm on simulated and noise-free data, at 1 and 5 GHz. These data are simulated in the presence of ideal trilinear surface-based ducts. The learning machine is based on a pregenerated database computed using Latin hypercube sampling to improve the efficiency of the learning. The results show that little accuracy is lost compared to a genetic algorithm approach. The computational time of a genetic algorithm is very high, whereas the learning machine approach is real time. The advantage of a real-time RFC system is that it could work on several azimuths in near real time.

  1. The aerodynamic characteristics of vortex ingestion for the F/A-18 inlet duct

    NASA Technical Reports Server (NTRS)

    Anderson, Bernhard H.

    1991-01-01

    A Reduced Navier-Stokes (RNS) solution technique was successfully combined with the concept of partitioned geometry and mesh generation to form a very efficient 3D RNS code aimed at the analysis-design engineering environment. Partitioned geometry and mesh generation is a pre-processor to augment existing geometry and grid generation programs which allows the solver to (1) recluster an existing gridlife mesh lattice, and (2) perturb an existing gridfile definition to alter the cross-sectional shape and inlet duct centerline distribution without returning to the external geometry and grid generator. The present results provide a quantitative validation of the initial value space marching 3D RNS procedure and demonstrates accurate predictions of the engine face flow field, with a separation present in the inlet duct as well as when vortex generators are installed to supress flow separation. The present results also demonstrate the ability of the 3D RNS procedure to analyze the flow physics associated with vortex ingestion in general geometry ducts such as the F/A-18 inlet. At the conditions investigated, these interactions are basically inviscid like, i.e., the dominant aerodynamic characteristics have their origin in inviscid flow theory.

  2. Laminar heat transfer in annular sector ducts

    SciTech Connect

    Soliman, H.M. )

    1987-02-01

    The continuing interest in compact heat exchangeers has created the need for friction factor and Nusselt number data for different passage shapes. It has long been recognized that circular tube results are generally not applicable to noncircular passages even when the hydraulic diameter is used as the characteristic dimension. Hence, design data should be generated for each passage individually, and a good source of such information is Shah and London. One duct geometry for which complete design information does not appear to be available in the open literature is that of annular sector ducts. Such configuration is encountered in multipassage internally finned tubes and many other compact het exchanger applications. The fluid flow problem for this configuration has been solved by Sparrow et al., and more recently by Niida. However, to the beest of the author's knowledge, the heat transfer results are not available yet. The purpose of this note is to summarize the analysis and results of fluid flow and heat transfer in annular sector ducts.

  3. Autoignitions and detonations in engines and ducts.

    PubMed

    Bradley, Derek

    2012-02-13

    The origins of autoignition at hot spots are analysed and the pressure pulses that arise from them are related to knock in gasoline engines and to developing detonations in ducts. In controlled autoignition engines, autoignition is benign with little knock. There are several modes of autoignition and the existence of an operational peninsula, within which detonations can develop at a hot spot, helps to explain the performance of various engines. Earlier studies by Urtiew and Oppenheim of the development of autoignitions and detonations ahead of a deflagration in ducts are interpreted further, using a simple one-dimensional theory of the generation of shock waves ahead of a turbulent flame. The theory is able to indicate entry into the domain of autoignition in an 'explosion in the explosion'. Importantly, it shows the influence of the turbulent burning velocity, and particularly its maximum attainable value, upon autoignition. This value is governed by localized flame extinctions for both turbulent and laminar flames. The theory cannot show any details of the transition to a detonation, but regimes of eventually stable or unstable detonations can be identified on the operational peninsula. Both regimes exhibit transverse waves, triple points and a cellular structure. In the case of unstable detonations, transverse waves are essential to the continuing propagation. For hazard assessment, more needs to be known about the survival, or otherwise, of detonations that emerge from a duct into the same mixture at atmospheric pressure. PMID:22213665

  4. The transient response above an evaporation duct

    NASA Astrophysics Data System (ADS)

    Abo-Seliem, Adel A. S.

    1998-11-01

    The transient electromagnetic field generated by a vertical electric dipole above an evaporation duct is investigated theoretically. The evaporation duct model used is that previously described by Kahan and Eckart. A vertical electric dipole, above the surface layer, is taken as the source of the electromagnetic field. We determine the electrical field strength exactly at some fixed point above the duct layer, having chosen a certain polarization of the primary source whose moment is allowed to vary arbitrarily with time. A series expansion with respect to the images of the primary source permits us to apply the method first reported by Cagniard and later extended by de Hoop and Frankena to the case where the source is positioned in a medium of lesser permittivity. Hence, we can give a physically intuitive description of the polarization dependence of the time history of the electrical field strength. The distinction of different cases where the distances between the receiving and transmitting ends are greater or lesser than the total reflection distance is studied. The electrical field strength is evaluated for different excitation functions at some fixed but arbitrary positions of the point of observation in the half-space.

  5. Radiative interactions in laminar duct flows

    NASA Technical Reports Server (NTRS)

    Trivedi, P. A.; Tiwari, S. N.

    1990-01-01

    Analyses and numerical procedures are presented for infrared radiative energy transfer in gases when other modes of energy transfer occur simultaneously. Two types of geometries are considered, a parallel plate duct and a circular duct. Fully developed laminar incompressible flows of absorbing-emitting species in black surfaced ducts are considered under the conditions of uniform wall heat flux. The participating species considered are OH, CO, CO2, and H2O. Nongray as well as gray formulations are developed for both geometries. Appropriate limiting solutions of the governing equations are obtained and conduction-radiation interaction parameters are evaluated. Tien and Lowder's wide band model correlation was used in nongray formulation. Numerical procedures are presented to solve the integro-differential equations for both geometries. The range of physical variables considered are 300 to 2000 K for temperature, 0.1 to 100.0 atm for pressure, and 0.1 to 100 cm spacings between plates/radius of the tube. An extensive parametric study based on nongray formulation is presented. Results obtained for different flow conditions indicate that the radiative interactions can be quite significant in fully developed incompressible flows.

  6. Pronephric duct extension in amphibian embryos: migration and other mechanisms.

    PubMed

    Drawbridge, Julie; Meighan, Christopher M; Lumpkins, Rebecca; Kite, Mary E

    2003-01-01

    Initiation of excretory system development in all vertebrates requires (1) delamination of the pronephric and pronephric duct rudiments from intermediate mesoderm at the ventral border of anterior somites, and (2) extension of the pronephric duct to the cloaca. Pronephric duct extension is the central event in nephric system development; the pronephric duct differentiates into the tubule that carries nephric filtrate out of the body and induces terminal differentiation of adult kidneys. Early studies concluded that pronephric ducts formed by means of in situ segregation of pronephric duct tissue from lateral mesoderm ventral to the forming somites; more recent studies highlight caudal migration of the pronephric duct as the major morphogenetic mechanism. The purpose of this review is to provide the historical background on studies of the mechanisms of amphibian pronephric duct extension, to review evidence showing that different amphibians perform pronephric duct morphogenesis in different ways, and to suggest future studies that may help illuminate the molecular basis of the mechanisms that have evolved in amphibians to extend the pronephric duct to the cloaca. PMID:12508219

  7. Accessory Pancreatic Duct Patterns and Their Clinical Implications

    PubMed Central

    Prasanna, Lokadolalu Chandracharya; Rajagopal, KV; Thomas, Huban R

    2015-01-01

    Context and Objective: Accessory pancreatic duct (APD) designed to reduce the pressure of major pancreatic duct by forming a secondary drainage channel. Few studies have mentioned the variant types of accessory ducts and their mode of formation, some of these have a clear clinical significance. Present study is aimed to evaluate the possible variations in the APD and its terminations. Materials and Methods: Forty formalin fixed adult human pancreas with duodenum in situ specimens were studied by injecting 1% aqueous eosin, followed by piece meal dissection of the head of the pancreas from posterior surface. Formation, tributaries, relations, and the termination of the accessory pancreatic duct were noted and photographed. Results: Accessory ducts revealed 50% belonged to long type, 22.5% were of short and ansa pancreatica type each, and embryonic type of duct pattern was seen in 5% specimens. 75% of long type ducts showed positive patency with eosin dye, followed by ansa type (44.4%), and least patency was found in short type (22.2%). With regard to the patency of the accessory pancreatic ducts towards their termination, we found 52.5% of the accessory ducts and 5% of the embryonic type pancreatic ducts were patent and in 42.5% of the specimen the ducts were obliterated. In 85% of specimens the minor duodenal papillae was anterosuperior to the major papilla and superior to the major papillae in 10% of the cases, and in 5% minor papillae was absent. The average distance between the two papillae was 2.35 cm. Conclusion: The knowledge of the complex anatomical relations of the gland with its duct, duodenum and bile ducts are essential for the surgeons and sinologists to plan and perform both the diagnostic as well as therapeutic procedures effectively. PMID:25954609

  8. Sustainable Mars Sample Return

    NASA Technical Reports Server (NTRS)

    Alston, Christie; Hancock, Sean; Laub, Joshua; Perry, Christopher; Ash, Robert

    2011-01-01

    The proposed Mars sample return mission will be completed using natural Martian resources for the majority of its operations. The system uses the following technologies: In-Situ Propellant Production (ISPP), a methane-oxygen propelled Mars Ascent Vehicle (MAV), a carbon dioxide powered hopper, and a hydrogen fueled balloon system (large balloons and small weather balloons). The ISPP system will produce the hydrogen, methane, and oxygen using a Sabatier reactor. a water electrolysis cell, water extracted from the Martian surface, and carbon dioxide extracted from the Martian atmosphere. Indigenous hydrogen will fuel the balloon systems and locally-derived methane and oxygen will fuel the MAV for the return of a 50 kg sample to Earth. The ISPP system will have a production cycle of 800 days and the estimated overall mission length is 1355 days from Earth departure to return to low Earth orbit. Combining these advanced technologies will enable the proposed sample return mission to be executed with reduced initial launch mass and thus be more cost efficient. The successful completion of this mission will serve as the next step in the advancement of Mars exploration technology.

  9. Higher Education Endowments Return

    ERIC Educational Resources Information Center

    Bahlmann, David; Walda, John D.; Sedlacek, Verne O.

    2012-01-01

    A new study of endowments by the National Association of College and University Business Officers (NACUBO) and the Commonfund Institute has brought good news to college and universities: While endowment returns dropped precipitously in fiscal year 2009 as a result of the financial crisis and accompanying slide in equity markets, they climbed to an…

  10. Return to Play

    ERIC Educational Resources Information Center

    Mangan, Marianne

    2013-01-01

    Call it physical activity, call it games, or call it play. Whatever its name, it's a place we all need to return to. In the physical education, recreation, and dance professions, we need to redesign programs to address the need for and want of play that is inherent in all of us.

  11. Optimizing Electrospray Interfaces Using Slowly Diverging Conical Duct (ConDuct) Electrodes

    PubMed Central

    Krutchinsky, Andrew N.; Padovan, Júlio C.; Cohen, Herbert; Chait, Brian T.

    2015-01-01

    We demonstrate that the efficiency of ion transmission from atmosphere to vacuum through stainless steel electrodes that contain slowly divergent conical duct (ConDuct) channels can be close to 100%. Here, we explore the properties of 2.5 cm long electrodes with angles of divergence of 0°, 1°, 2°, 3°, 5°, 8°, 13°, and 21°, respectively. The ion transmission efficiency was observed to jump from 10–20% for the 0° (straight) channels to 90–95% for channels with an angle of divergence as small as 1°. Furthermore, the 2–3° ConDuct electrodes produced extraordinarily low divergence ion beams that propagated in a laser-like fashion over long distances in vacuum. To take advantage of these newly discovered properties, we constructed a novel atmosphere-to-vacuum ion interface utilizing a 2° ConDuct as an inlet electrode and compared its ion transmission efficiency with that of the interface used in the commercial (Thermo) Velos Orbitrap and Q Exactive mass spectrometers. We observed that the ConDuct interface transmitted up to 17 times more ions than the commercial reference interface and also yielded improved signal-to-noise mass spectra of peptides. We infer from these results that the performance of many current atmosphere-tovacuum interfaces utilizing metal capillaries can be substantially improved by replacing them with 1° or 2° metal ConDuct electrodes, which should preserve the convenience of supplying ion desolvation energy by heating the electrode while greatly increasing the efficiency of ion transmission into the mass spectrometer. PMID:25667060

  12. Duct wall impedance control as an advanced concept for acoustic suppression enhancement. [engine noise reduction

    NASA Technical Reports Server (NTRS)

    Dean, P. D.

    1978-01-01

    A systems concept procedure is described for the optimization of acoustic duct liner design for both uniform and multisegment types. The concept was implemented by the use of a double reverberant chamber flow duct facility coupled with sophisticated computer control and acoustic analysis systems. The optimization procedure for liner insertion loss was based on the concept of variable liner impedance produced by bias air flow through a multilayer, resonant cavity liner. A multiple microphone technique for in situ wall impedance measurements was used and successfully adapted to produce automated measurements for all liner configurations tested. The complete validation of the systems concept was prevented by the inability to optimize the insertion loss using bias flow induced wall impedance changes. This inability appeared to be a direct function of the presence of a higher order energy carrying modes which were not influenced significantly by the wall impedance changes.

  13. Effect of flow on the acoustic performance of extended reaction lined ducts

    NASA Technical Reports Server (NTRS)

    Hersh, A. S.; Walker, B.

    1983-01-01

    A model is developed for the effects of uniform and boundary-layer mean flow on the attenuation and propagation of harmonically excited sound waves in an extended reaction lined cylindrical duct. A duct geometry consisting of an annular outer region of bulk material surrounding an inner cylinder of air is utilized. A numerical solution is obtained for the coupled wave equations governing the motion of the sound in both the inner and annular regions. It is found that the numerically predicted attenuation and propagations constants are in excellent agreement with measured values using Kevlar as the liner material for plane-wave mode (O,O) excitation over a wide range of mean flows and sound frequency. The boundary-layer effects are determined to be unimportant, at least for plane-wave sound. In addition, numerical studies indicate small differences between the use of either the radial velocity or the radial displacement boundary conditions.

  14. Peripheral temperature variation in the wall of a noncircular duct - An experimental investigation

    NASA Astrophysics Data System (ADS)

    Barrow, H.; Hassan, A. K. A.; Avgerinos, C.

    1984-07-01

    This paper is concerned with the peripheral variation of the temperature in the wall of a straight noncircular duct, with special reference to the prediction of the temperature in the cladding of the fuel rods of a pressurized water reactor, in the event of a loss of coolant. A simple model of the conjugate heat transfers in the wall and the fluid is used to predict the temperature variation around the wall. To test the theory, experiments have been made to determine wall temperatures in a cusped duct using air as the working fluid for a range of fluid flow rates. Overall pressure drop and heat transfer measurements for friction factor and average heat transfer coefficient indicate the inadequacy of the hydraulic radius concept in the case of the very noncircular geometry used in the experiments, and the effect of asymmetry in heat transfer. It is thought that these heat transfer experiments are the first for this particular geometry.

  15. Method and apparatus for duct sealing using a clog-resistant insertable injector

    DOEpatents

    Wang, Duo; Modera, Mark P.

    2007-01-02

    A clog-resistant injector spray nozzle allows relatively unobtrusive insertion through a small access aperture into existing ductwork in occupied buildings for atomized particulate sealing of a ductwork. The spray nozzle comprises an easily cleaned and easily replaced straight liquid tube whose liquid contents are principally propelled by a heated propellant gas, such as heated air. Heat transfer is minimized from the heated propellant gas to the liquid tube until they both exit the injector, thereby greatly reducing the likelihood of nozzle clogging. A method of duct sealing using particles driven by heated propellant gas is described, whereby duct-sealing operations become both faster, and commercially practicable in inhabited commercial and residential buildings.

  16. Experimental validation of a ducted propeller analysis method

    NASA Astrophysics Data System (ADS)

    Hughes, M. J.; Kinnas, S. A.; Kerwin, J. E.

    1992-06-01

    A ducted propeller model was tested in the MIT water tunnel. A hub apparatus was designed which allowed for the duct and propeller forces to be measured separately. The forces on the duct and propeller were measured over a range of advance coefficients. Velocities were measured upstream and downstream from the duct using a Laser Doppler Velocimetry system. Using these velocities the exprimental values for the spanwise distribution of circulation on the propeller blades were then calculated. The experimental results were compared to the results from a propeller lifting surface/duct and hub surface panel analysis code over the same range of advance coefficients showing very good agreement for the duct and propeller forces and the circulation in the region of attached flow.

  17. Optimization of the mechanical performance of a two-duct semicircular duct system--part 3: the positioning of the ducts in the head.

    PubMed

    Muller, M; Verhagen, J H G

    2002-06-21

    In the majority of vertebrates, the horizontal duct of the vestibular system lies approximately in the yawing plane of the head. The positioning of the vertical ducts, however, is not in the pitch- and roll planes but the vertical ducts generally lie under an angle of about 30-45 degrees relative to the medial plane. Using the equations for a hydrodynamically interconnected two-duct system, optimal positions of the vertical and horizontal ducts in different vertebrate groups can be derived. It was stated that the mean response of the vertical ducts should be optimized. This leads to a symmetrical positioning of the vertical ducts with respect to the medial plane. In all observed vertebrate groups, a solution of mu =(pi-alpha)/2 is found (mu is the angle of the vertical ducts relative to the medial plane, alpha is the angle between the vertical duct planes). For alpha=90 degrees, this provides an equal sensitivity for pitch- and roll- movements. For alpha>90 degrees, a larger sensitivity for pitch movements is obtained, at the expense of a lower sensitivity for roll movements. It is argued that the angle alpha between the vertical ducts may vary from 90 to 120 degrees. In most vertebrates, the centre of mass is stabilized by e.g. fins, tri- or quadrupedal stability, a crawling body or upside-down resting positions (e.g. bats). Birds are generally biped, so in walking they are also rather sensitive to roll. These features are related to labyrinth positioning in the head. PMID:12151260

  18. Phobos Sample Return mission

    NASA Astrophysics Data System (ADS)

    Zelenyi, Lev; Zakharov, A.; Martynov, M.; Polischuk, G.

    Very mysterious objects of the Solar system are the Martian satellites, Phobos and Deimos. Attempt to study Phobos in situ from an orbiter and from landers have been done by the Russian mission FOBOS in 1988. However, due to a malfunction of the onboard control system the landers have not been delivered to the Phobos surface. A new robotics mission to Phobos is under development now in Russia. Its main goal is the delivery of samples of the Phobos surface material to the Earth for laboratory studies of its chemical, isotopic, mineral composition, age etc. Other goals are in situ studies of Phobos (regolith, internal structure, peculiarities in orbital and proper rotation), studies of Martian environment (dust, plasma, fields). The payload includes a number of scientific instruments: gamma and neutron spectrometers, gaschromatograph, mass spectrometers, IR spectrometer, seismometer, panoramic camera, dust sensor, plasma package. To implement the tasks of this mission a cruise-transfer spacecraft after the launch and the Earth-Mars interplanetary flight will be inserted into the first elliptical orbit around Mars, then after several corrections the spacecraft orbit will be formed very close to the Phobos orbit to keep the synchronous orbiting with Phobos. Then the spacecraft will encounter with Phobos and will land at the surface. After the landing the sampling device of the spacecraft will collect several samples of the Phobos regolith and will load these samples into the return capsule mounted at the returned vehicle. This returned vehicle will be launched from the mother spacecraft and after the Mars-Earth interplanetary flight after 11 monthes with reach the terrestrial atmosphere. Before entering into the atmosphere the returned capsule will be separated from the returned vehicle and will hopefully land at the Earth surface. The mother spacecraft at the Phobos surface carrying onboard scientific instruments will implement the "in situ" experiments during an year

  19. Design and evaluation of a low nitrogen oxides natural gas-fired conical wire-mesh duct burner for a micro-cogeneration unit

    NASA Astrophysics Data System (ADS)

    Ramadan, Omar Barka Ab

    A novel low NOx conical wire-mesh duct burner was designed, built and tested in the present research. This thesis documents the design process and the in-depth evaluation of this novel duct burner for the development of a more efficient micro-cogeneration unit. This duct burner provides the thermal energy necessary to raise the microturbine exhaust gases temperature to increase the heat recovery capability. The duct burner implements both lean-premixed and surface combustion techniques to achieve low NOx and CO emissions. The design of the duct burner was supported by a qualitative flow visualization study for the duct burner premixer to provide insight into the premixer flow field (mixing process). Different premixer geometries were used to control the homogeneity of the fuel-oxidant mixture at the exit of the duct burner premixer. Laser sheet illumination (LSI) technique was used to capture images of the mixing process, for each configuration studied. A quasi-quantitative analysis technique was developed to rank the different premixer geometries in terms of mixing effectiveness. The premixer geometries that provided better mixing were selected and used for the combustion tests. The full-scale gas-fired duct burner was installed in the exhaust duct of a micro-cogeneration unit for the evaluation. Three wire-mesh burners with different pressure drops were used. Each burner has a conical shape made from FeCrAL alloy mat and was designed based on a heat release per unit area of 2500 kW/m2 and a total heat release of 240kW at 100 percent excess air. The local momentum of the gaseous mixture introduced through the wire-mesh was adjusted so that the flame stabilized outside the burner mesh (surface combustion). Cold flow tests (i.e., the duct burner was off, but the microturbine was running) were conducted to measure the effect of different duct burner geometrical parameters on flow split between the combustion zone and the bypass channel, and on pressure drop across

  20. Air heating system

    DOEpatents

    Primeau, John J.

    1983-03-01

    A self-starting, fuel-fired, air heating system including a vapor generator, a turbine, and a condenser connected in a closed circuit such that the vapor output from the vapor generator is conducted to the turbine and then to the condenser where it is condensed for return to the vapor generator. The turbine drives an air blower which passes air over the condenser for cooling the condenser. Also, a condensate pump is driven by the turbine. The disclosure is particularly concerned with the provision of heat exchanger and circuitry for cooling the condensed fluid output from the pump prior to its return to the vapor generator.

  1. Assured Crew Return Vehicle

    NASA Technical Reports Server (NTRS)

    Stone, D. A.; Craig, J. W.; Drone, B.; Gerlach, R. H.; Williams, R. J.

    1991-01-01

    The developmental status is discussed regarding the 'lifeboat' vehicle to enhance the safety of the crew on the Space Station Freedom (SSF). NASA's Assured Crew Return Vehicle (ACRV) is intended to provide a means for returning the SSF crew to earth at all times. The 'lifeboat' philosophy is the key to managing the development of the ACRV which further depends on matrixed support and total quality management for implementation. The risk of SSF mission scenarios are related to selected ACRV mission requirements, and the system and vehicle designs are related to these precepts. Four possible ACRV configurations are mentioned including the lifting-body, Apollo shape, Discoverer shape, and a new lift-to-drag concept. The SCRAM design concept is discussed in detail with attention to the 'lifeboat' philosophy and requirements for implementation.

  2. Patent vitellointestinal duct as paraumblical abcess: A rare presentation

    PubMed Central

    Rekhi, Harnam Singh; Mittal, Sushil; Singh, Gurtej; Rekhi, Balwinder Kaur; Dugg, Pankaj

    2015-01-01

    Introduction Umbilical and paraumblical abscess can occur in children with presenting complaint of discharge from umbilical region. However, patent vitello intestinal duct presenting as paraumblical abscess is rare phenomenon. Presentation of case One year old male child presented with complain of discharge from umbilical region since birth. Incision & drainage done twice thinking it to be paraumblical abscess. Discussion Vitellointestinal duct as abscess is rare presentation but it should be considered as a differential diagnosis of discharging umbilicus as management of abscess and patent duct are different. Conclusion Patent vitellointestinal duct can present as paraumbilical abscess, and it should be kept in differential diagnosis specifically in children. PMID:26301682

  3. Duct injection technology prototype development: Evaluation of engineering data

    SciTech Connect

    Not Available

    1990-07-01

    The objective of the Duct Injection Technology Prototype Development Project is to develop a sound design basis for applying duct injection technology as a post-combustion SO{sub 2}emissions control method to existing coal-fired power plants. The necessary engineering design and scale-up criteria will be developed for the commercialization of duct injection technology for the control of SO{sub 2} emissions from coal-fired boilers in the utility industry. The primary focus of the analyses summarized in this Topical Report is the review of the known technical and economic information associated with duct injection technology. (VC)

  4. Duct Remediation Program: Engineered access research and construction

    SciTech Connect

    Beckman, T.D.; Davis, M.M.; Karas, T.M.

    1992-11-01

    The Rocky Flats Plant, Duct Remediation mission concentrated on removing Plutonium Oxide from the process ductwork in the primary Plutonium processing facility. When possible, remediation took place from existing process gloveboxes. Fifteen locations were identified, however, that required accessing duct runs where no process gloveboxes existed. The building`s second floor utility areas had many locations where long, inaccessible duct runs were prevalent. Consequently, an extensive program for design, procurement and construction was initiated to contain and isolate ducts for penetration when existing glovebox sites were not present.

  5. Leaf seal for transition duct in turbine system

    SciTech Connect

    Flanagan, James Scott; LeBegue, Jeffrey Scott; McMahan, Kevin Weston; Dillard, Daniel Jackson; Pentecost, Ronnie Ray

    2013-06-11

    A turbine system is disclosed. In one embodiment, the turbine system includes a transition duct. The transition duct includes an inlet, an outlet, and a passage extending between the inlet and the outlet and defining a longitudinal axis, a radial axis, and a tangential axis. The outlet of the transition duct is offset from the inlet along the longitudinal axis and the tangential axis. The transition duct further includes an interface member for interfacing with a turbine section. The turbine system further includes a leaf seal contacting the interface member to provide a seal between the interface member and the turbine section.

  6. Convolution seal for transition duct in turbine system

    SciTech Connect

    Flanagan, James Scott; LeBegue, Jeffrey Scott; McMahan, Kevin Weston; Dillard, Daniel Jackson; Pentecost, Ronnie Ray

    2015-03-10

    A turbine system is disclosed. In one embodiment, the turbine system includes a transition duct. The transition duct includes an inlet, an outlet, and a passage extending between the inlet and the outlet and defining a longitudinal axis, a radial axis, and a tangential axis. The outlet of the transition duct is offset from the inlet along the longitudinal axis and the tangential axis. The transition duct further includes an interface member for interfacing with a turbine section. The turbine system further includes a convolution seal contacting the interface member to provide a seal between the interface member and the turbine section.

  7. Flexible metallic seal for transition duct in turbine system

    SciTech Connect

    Flanagan, James Scott; LeBegue, Jeffrey Scott; McMahan, Kevin Weston; Dillard, Daniel Jackson; Pentecost, Ronnie Ray

    2014-04-22

    A turbine system is disclosed. In one embodiment, the turbine system includes a transition duct. The transition duct includes an inlet, an outlet, and a passage extending between the inlet and the outlet and defining a longitudinal axis, a radial axis, and a tangential axis. The outlet of the transition duct is offset from the inlet along the longitudinal axis and the tangential axis. The transition duct further includes an interface member for interfacing with a turbine section. The turbine system further includes a flexible metallic seal contacting the interface member to provide a seal between the interface member and the turbine section.

  8. Buried and Encapsulated Ducts, Jacksonville, Florida (Fact Sheet)

    SciTech Connect

    Not Available

    2013-11-01

    Ductwork installed in unconditioned attics can significantly increase the overall heating and cooling costs of residential buildings. In fact, estimated duct thermal losses for single-family residential buildings with ductwork installed in unconditioned attics range from 10% to 45%. In a study of three single-story houses in Florida, the Building America research team Consortium for Advanced Residential Buildings (CARB) investigated the strategy of using buried and/or encapsulated ducts (BED) to reduce duct thermal losses in existing homes. The BED strategy consists of burying ducts in loose-fill insulation and/or encapsulating them in closed cell polyurethane spray foam (ccSPF) insulation. There are three possible combinations of BED strategies: (1) buried ducts; (2) encapsulated ducts (with ccSPF); and (3) buried and encapsulated ducts. The best solution for each situation depends on the climate, age of the house, and the configuration of the HVAC system and attic. For new construction projects, the team recommends that ducts be both encapsulated and buried as the minimal planning and costs required for this will yield optimal energy savings. The encapsulated/buried duct strategy, which utilizes ccSPF to address condensation concerns, is an approach that was developed specifically for humid climates.

  9. Analysis of nephric duct specification in the avian embryo

    PubMed Central

    Attia, Lital; Yelin, Ronit; Schultheiss, Thomas M.

    2012-01-01

    Vertebrate kidney tissue exhibits variable morphology that in general increases in complexity when moving from anterior to posterior along the body axis. The nephric duct, a simple unbranched epithelial tube, is derived in the avian embryo from a rudiment located in the anterior intermediate mesoderm (IM) adjacent to somites 8 to 10. Using quail-chick chimeric embryos, the current study finds that competence to form nephric duct is fixed when IM precursor cells are still located in the primitive streak, significantly before the onset of duct differentiation. In the primitive streak, expression of the gene HoxB4 is associated with prospective duct IM, whereas expression of the more posterior Hox gene HoxA6 is associated with more posterior, non-duct-forming IM. Misexpression of HoxA6, but not of HoxB4, in prospective duct-forming regions of the IM resulted in repression of duct formation, suggesting a mechanism for the restriction of duct formation to the anterior-most IM. The results are discussed with respect to their implications for anterior-posterior patterning of kidney tissue and of mesoderm in general, and for the loss of duct-forming ability in more posterior regions of the IM that has occurred during vertebrate evolution. PMID:23034630

  10. 24 CFR 3280.715 - Circulating air systems.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 24 Housing and Urban Development 5 2014-04-01 2014-04-01 false Circulating air systems. 3280.715... Systems § 3280.715 Circulating air systems. Link to an amendment published at 78 FR 73989, Dec. 9, 2013... steel, tin-plated steel, or aluminum, or shall be listed Class 0, Class 1, or Class 2 air ducts. Class...

  11. Postoperative Chemoradiotherapy for Extrahepatic Bile Duct Cancer

    SciTech Connect

    Park, Jin-hong; Choi, Eun Kyung; Ahn, Seung Do; Lee, Sang-wook; Song, Si Yeol; Yoon, Sang Min; Kim, Young Seok; Lee, Yu Sun; Lee, Sung-Gyu; Hwang, Shin; Lee, Young-Joo; Park, Kwang-Min; Kim, Tae Won; Chang, Heung Moon; Lee, Jae-Lyun; Kim, Jong Hoon

    2011-03-01

    Purpose: To evaluate the effect of postoperative concurrent chemoradiotherapy using three-dimensional conformal radiotherapy and to identify the prognostic factors that influence survival in patients with extrahepatic bile duct cancer. Methods and Materials: We retrospectively analyzed the data from 101 patients with extrahepatic bile duct cancer who had undergone postoperative concurrent chemoradiotherapy using three-dimensional conformal radiotherapy. Of the 101 patients, 52 (51%) had undergone complete resection (R0 resection) and 49 (49%) had microscopic or macroscopic residual tumors (R1 or R2 resection). The median radiation dose was 50 Gy. Also, 85 patients (84%) underwent concurrent chemotherapy with 5-fluorouracil. Results: The median follow-up period was 47 months for the surviving patients. The 5-year overall survival rate was 34% for all patients. A comparison between patients with R0 and R1 resection indicated no significant difference in the 5-year overall survival (44% vs. 33%, p = .2779), progression-free survival (35% vs. 22%, p = .3107), or locoregional progression-free survival (75% vs. 63%, p = .2784) rates. An analysis of the first failure site in the 89 patients with R0 or R1 resection indicated isolated locoregional recurrence in 7 patients. Elevated postoperative carbohydrate antigen 19-9 level was an independent prognostic factor for overall survival (p = .001) and progression-free survival (p = .033). A total of 3 patients developed Grade 3 or greater late toxicity. Conclusion: Adjuvant concurrent chemoradiotherapy using three-dimensional conformal radiotherapy appears to improve locoregional control and survival in extrahepatic bile duct cancer patients with R1 resection. The postoperative carbohydrate antigen 19-9 level might be a useful prognostic marker to select patients for more intensified adjuvant therapy.

  12. Radiation of sound from unflanged cylindrical ducts

    NASA Technical Reports Server (NTRS)

    Hartharan, S. L.; Bayliss, A.

    1983-01-01

    Calculations of sound radiated from unflanged cylindrical ducts are presented. The numerical simulation models the problem of an aero-engine inlet. The time dependent linearized Euler equations are solved from a state of rest until a harmonic solution is attained. A fourth order accurate finite difference scheme is used and solutions are obtained from a fully vectorized Cyber-203 computer program. Cases of both plane waves and spin modes are treated. Spin modes model the sound generated by a turbofan engine. Boundary conditions for both plane waves and spin modes are treated. Solutions obtained are compared with experiments conducted at NASA Langley Research Center.

  13. Levitated Duct Fan (LDF) Aircraft Auxiliary Generator

    NASA Technical Reports Server (NTRS)

    Eichenberg, Dennis J.; Emerson, Dawn C.; Gallo, Christopher A.; Thompson, William K.

    2011-01-01

    This generator concept includes a novel stator and rotor architecture made from composite material with blades attached to the outer rotating shell of a ducted fan drum rotor, a non-contact support system between the stator and rotor using magnetic fields to provide levitation, and an integrated electromagnetic generation system. The magnetic suspension between the rotor and the stator suspends and supports the rotor within the stator housing using permanent magnets attached to the outer circumference of the drum rotor and passive levitation coils in the stator shell. The magnets are arranged in a Halbach array configuration.

  14. Anatomy of the nipple and breast ducts.

    PubMed

    Zucca-Matthes, Gustavo; Urban, Cícero; Vallejo, André

    2016-02-01

    Over time, variations of mastectomy came up and started allowing the oncological safety and the possibility of an immediate breast reconstruction. Nipple sparing mastectomy (NSM) procedures have strongly increased in frequency and have become one of the best alternatives to treat breast cancer, also improving overall aesthetic outcomes and the achievement of contralateral breast symmetry. The nipple areola-complex (NAC) must be considered the identity of the breast concerning self-esteem of patients. This paper will remind the main anatomical topics around the nipple and breast ducts. PMID:26855906

  15. [Carcinoma of the extrahepatic bile ducts].

    PubMed

    Cappelletti, F; Marzano, P F; Giacinti, I; Di Bello, M G; Maturo, A; Di Matteo, F M; Micacchi, M; Zaccagnino, P; Morucci, R; Petrassi, P; Ascenzi, P; Di Curzio, B

    1996-01-01

    In the last 5 years 25 patients (11 men, 14 women) with carcinoma of the extrahepatic biliary duct were studied. The most frequent localization of the carcinoma was the hepatic hilum. D.C.P. according to Whipple was possible only in one patient, while in 20 patients a palliative approach with external and internal biliary derivations was the choice. In the remaining 4 patients an explorative laparotomy with biopsy was performed. It is concluded that palliative resection allows for a better quality of life. PMID:9162182

  16. Porokeratotic eccrine ostial and dermal duct nevus

    PubMed Central

    Bandyopadhyay, Debabrata; Saha, Abanti; Das, Dipti; Das, Anupam

    2015-01-01

    Porokeratotic eccrine ostial and dermal duct nevus (PEODDN) is a rare nevoid condition characterized by asymptomatic grouped keratotic papules and plaques with a linear pattern on the extremities, having distinct porokeratotic histopathological features. The lesions usually present at birth or in childhood. We present here a case of late-onset PEODDN in a 23-year-old man who had lesions on the palm, forearm, arm and the chest along the lines of Blaschko, strictly localized to the left side of the body. PMID:25821735

  17. Anatomy of the nipple and breast ducts

    PubMed Central

    Urban, Cícero; Vallejo, André

    2016-01-01

    Over time, variations of mastectomy came up and started allowing the oncological safety and the possibility of an immediate breast reconstruction. Nipple sparing mastectomy (NSM) procedures have strongly increased in frequency and have become one of the best alternatives to treat breast cancer, also improving overall aesthetic outcomes and the achievement of contralateral breast symmetry. The nipple areola-complex (NAC) must be considered the identity of the breast concerning self-esteem of patients. This paper will remind the main anatomical topics around the nipple and breast ducts. PMID:26855906

  18. [Liver, bile ducts and pancreatic diseases].

    PubMed

    Kanno, T

    1995-06-01

    A fundamental guideline for the use of test results concerning liver, bile duct and pancreatic diseases was proposed in 1991 from the Japan Society of Clinical Pathology (JSCP). This guideline was principally based on the document of 1988 from the Committee on liver function tests of the Japanese Society of Gastroenterology (JSG). The document from the JSG was revised in May, 1994. Also a guideline for selection of markers of hepatitis virus in hepatic disorders, was proposed in January, 1994 from the same Committee of JSG. Here, we reevaluated and discussed the JSCP guideline as taking into consideration the two 1994 JSG documents. PMID:7602802

  19. Detonation duct gas generator demonstration program

    NASA Technical Reports Server (NTRS)

    Wortman, A.; Othmer, P.; Rostafinski, W.

    1992-01-01

    An experimental demonstration is presented for the generation of detonation waves that move periodically across high speed channel flow; these waves can compress the outflow from a low pressure compressor, and thereby both reduce the compressor requirements associated with conventional gas turbines and enhance thermodynamic efficiency through isochoric energy addition. By generating transient transverse waves, rather than standing waves, shock-wave losses are reduced by an order of magnitude; the result is a Humphrey cycle augmenting the basic Brayton-cycle gas turbine. Attention is presently given to results from an experimental detonation duct.

  20. Turbulent flame speeds in ducts and the deflagration/detonation transition

    SciTech Connect

    Bradley, D.; Lawes, M.; Liu, Kexin

    2008-07-15

    A methodology is proposed for determining whether a deflagration-to-detonation transition (DDT) might occur for flame propagation along a duct with baffles, closed at the ignition end. A flammable mixture can attain a maximum turbulent burning velocity. If this is sufficiently high, a strong shock is formed ahead of the flame. It is assumed that this maximum burning velocity is soon attained and on the basis of previous studies, this value can be obtained for the given conditions. The increase in temperature and pressure of the reactants, due to the shock, further increases the maximum turbulent burning velocity. The gas velocity ahead of the flame is linked to one-dimensional shock wave equations in a numerical analysis. The predicted duct flame speeds with the appropriate maximum turbulent burning velocities are in good agreement with those measured in the slow and fast flame regimes of a range of CH{sub 4}-air and H{sub 2}-air mixtures. DDTs are possible if autoignition of the reactants occurs in the time available, and if the projected flame speed approaches the Chapman-Jouguet velocity at the same temperature and pressure. Prediction of the first condition requires values of the autoignition delay time of the mixture at the shocked temperatures and pressures. Prediction of the second requires values of the laminar burning velocity and Markstein number. With the appropriate values of these parameters, it is shown numerically that there is no DDT with CH{sub 4}-air. With H{sub 2}-air, the onset of DDT occurs close to the values of equivalence ratio at which it has been observed experimentally. The effects of different duct sizes also are predicted, although details of the DDT cannot be predicted. Extension of the study to a wider range of fuels requires more data on their laminar burning velocities and Markstein numbers at higher temperatures and pressures and on autoignition delay times at lower temperatures and pressures. (author)

  1. Distribution and Room Air Mixing Risks to Retrofitted Homes

    SciTech Connect

    Burdick, A.

    2014-12-01

    ​Energy efficiency upgrades reduce heating and cooling loads on a house. With enough load reduction and if the HVAC system warrants replacement, the HVAC system is often upgraded with a more efficient, lower capacity system that meets the loads of the upgraded house. For a single-story house with ceiling supply air diffusers, ducts are often removed and upgraded. For houses with ducts that are embedded in walls, the cost of demolition precludes the replacement of ducts. The challenge with the use of existing ducts is that the reduced airflow creates a decreased throw at the supply registers, and the supply air and room air do not mix well, leading to potential thermal comfort complaints. This project investigates this retrofit scenario. The issues and solutions discussed here are relevant to all climate zones, with emphasis on climates that require cooling.

  2. Distribution and Room Air Mixing Risks to Retrofitted Homes

    SciTech Connect

    Burdick, A.

    2014-12-01

    Energy efficiency upgrades reduce heating and cooling loads on a house. With enough load reduction and if the HVAC system warrants replacement, the HVAC system is often upgraded with a more efficient, lower capacity system that meets the loads of the upgraded house. For a single-story house with ceiling supply air diffusers, ducts are often removed and upgraded. For houses with ducts that are embedded in walls, the cost of demolition precludes the replacement of ducts. The challenge with the use of existing ducts is that the reduced airflow creates a decreased throw at the supply registers, and the supply air and room air do not mix well, leading to potential thermal comfort complaints. This project investigates this retrofit scenario. The issues and solutions discussed here are relevant to all climate zones, with emphasis on climates that require cooling.

  3. Improving air handler efficiency in houses

    SciTech Connect

    Walker, Iain S.

    2004-05-01

    Although furnaces, air conditioners and heat pumps have become significantly more efficient over the last couple of decades, residential air handlers have typical efficiencies of only 10% to 15% due to poor electric motor performance and aerodynamically poor fans and fan housings. Substantial increases in performance could be obtained through improved air handler design and construction. A prototype residential air handler intended to address these issues has recently been developed. The prototype and a standard production fan were tested in a full-scale duct system and test chamber at LBNL specifically designed for testing heating, ventilation, and air conditioning systems. The laboratory tests compared efficiency, total airflow, sensitivity to duct system flow resistance, and the effects of installation in a smaller cabinet. The test results showed that the prototype air handler had about twice the efficiency of the standard air handler (averaged over a wide range of operating conditions) and was less sensitive to duct system flow resistance changes. The performance of both air handlers was significantly reduced by reducing the clearance between the air handler and cabinet it was placed in. These test results showed that in addition to the large scope for performance improvement, air handler fans need to be tested in the cabinets they operate in.

  4. Ultrasound imaging of the mouse pancreatic duct using lipid microbubbles

    NASA Astrophysics Data System (ADS)

    Banerjee, B.; McKeown, K. R.; Skovan, B.; Ogram, E.; Ingram, P.; Ignatenko, N.; Paine-Murrieta, G.; Witte, R.; Matsunaga, T. O.

    2012-03-01

    Research requiring the murine pancreatic duct to be imaged is often challenging due to the difficulty in selectively cannulating the pancreatic duct. We have successfully catheterized the pancreatic duct through the common bile duct in severe combined immune deficient (SCID) mice and imaged the pancreatic duct with gas filled lipid microbubbles that increase ultrasound imaging sensitivity due to exquisite scattering at the gas/liquid interface. A SCID mouse was euthanized by CO2, a midline abdominal incision made, the common bile duct cut at its midpoint, a 2 cm, 32 gauge tip catheter was inserted about 1 mm into the duct and tied with suture. The duodenum and pancreas were excised, removed in toto, embedded in agar and an infusion pump was used to instill normal saline or lipid-coated microbubbles (10 million / ml) into the duct. B-mode images before and after infusion of the duct with microbubbles imaged the entire pancreatic duct (~ 1 cm) with high contrast. The microbubbles were cavitated by high mechanical index (HMI) ultrasound for imaging to be repeated. Our technique of catheterization and using lipid microbubbles as a contrast agent may provide an effective, affordable technique of imaging the murine pancreatic duct; cavitation with HMI ultrasound would enable repeated imaging to be performed and clustering of targeted microbubbles to receptors on ductal cells would allow pathology to be localized accurately. This research was supported by the Experimental Mouse Shared Service of the AZ Cancer Center (Grant Number P30CA023074, NIH/NCI and the GI SPORE (NIH/NCI P50 CA95060).

  5. Collecting duct intercalated cell function and regulation.

    PubMed

    Roy, Ankita; Al-bataineh, Mohammad M; Pastor-Soler, Núria M

    2015-02-01

    Intercalated cells are kidney tubule epithelial cells with important roles in the regulation of acid-base homeostasis. However, in recent years the understanding of the function of the intercalated cell has become greatly enhanced and has shaped a new model for how the distal segments of the kidney tubule integrate salt and water reabsorption, potassium homeostasis, and acid-base status. These cells appear in the late distal convoluted tubule or in the connecting segment, depending on the species. They are most abundant in the collecting duct, where they can be detected all the way from the cortex to the initial part of the inner medulla. Intercalated cells are interspersed among the more numerous segment-specific principal cells. There are three types of intercalated cells, each having distinct structures and expressing different ensembles of transport proteins that translate into very different functions in the processing of the urine. This review includes recent findings on how intercalated cells regulate their intracellular milieu and contribute to acid-base regulation and sodium, chloride, and potassium homeostasis, thus highlighting their potential role as targets for the treatment of hypertension. Their novel regulation by paracrine signals in the collecting duct is also discussed. Finally, this article addresses their role as part of the innate immune system of the kidney tubule. PMID:25632105

  6. Evaporation duct effects at millimeter wavelengths

    NASA Astrophysics Data System (ADS)

    Anderson, K. D.

    1992-03-01

    The evaporation duct strongly influences low-altitude over-the-horizon propagation at millimeter wavelengths. Results from more than 2000 hours of propagation and meteorological measurements made at 94 GHz on a 40.6 km over-horizon, over-water path along the southern California coast show that the average received power was 63 dB greater than d for propagation in a nonducting, or standard, atmosphere; 90 percent of the measurements were at least 55 dB greater than diffraction. A numerical model of transmission loss based on the observed surface meteorology is discussed and results are compared to measured transmission loss. On average, modeling results underestimate observations by only 10 dB. In addition, results from modeling based on an independent climatology of evaporation duct heights for the area are shown to be adequate for most propagation assessment purposes. The reliability and reasonable accuracy of the numerical model provides a strong justification for utilizing the technique to assess millimeter wave communication and radar systems operating in many, if not all, ocean regions.

  7. Evaporation duct effects at millimeter wavelengths

    NASA Astrophysics Data System (ADS)

    Anderson, K. D.

    1990-03-01

    The evaporation duct strongly influences low-altitude over-the horizon propagation at millimeter wavelengths. Results from more than 2000 hours of propagation and meteorological measurements were made at 94 GHz on a 40.6 km over-horizon, over-water path along the southern California coast show that the average received power was 63 dB greater than expected for propagation in a nonconducting, or normal, atmosphere; 90 percent of the measurements were at least 55 dB greater than the normal atmosphere. A numerical model of transmission loss based on observed surface meteorology is discussed and results are compared to measured transmission loss. On average, modeling results underestimate the transmission loss by 10 dB. In addition, results from modeling based on an independent climatology of evaporation duct heights for the area are shown to be adequate for most propagation assessment purposes. The reliability and reasonable accuracy of the model provide a strong justification for utilizing the technique to assess millimeter wave communication and radar systems operating in many, if not all, ocean regions.

  8. Returns to Education in Bangladesh

    ERIC Educational Resources Information Center

    Asadullah, Mohammad Niaz

    2006-01-01

    This paper reports labour market returns to education in Bangladesh using data from recent nationwide household survey. Returns are estimated separately for rural and urban samples, males, females and private-sector employees. Substantial heterogeneity in returns is observed; for example, estimates are higher for urban (than rural sample) and…

  9. Energy Vs. Productivity: Diminishing Returns

    ERIC Educational Resources Information Center

    MOSAIC, 1975

    1975-01-01

    Energy invested in corn production is compared with food energy returned in calculations by David Pimentel at Cornell University. The rate of return is falling off sharply in this already energy-intensive agriculture. Increased energy input, in the form of fertilizer, would yield far greater returns where agriculture is less sophisticated.…

  10. A Look at Returning Teachers

    ERIC Educational Resources Information Center

    DeAngelis, Karen J.

    2013-01-01

    Research shows that one-quarter to one-third of teachers who leave the profession return, the majority after only a short absence. Though returning teachers can constitute a substantial share of newly hired teachers in schools each year, little is known about them, the factors associated with their decisions to return, or the schools to which…

  11. Puerto Rican Return Migrant Youth.

    ERIC Educational Resources Information Center

    Carrasquillo, Angela; Carrasquillo, Ceferino

    Among Puerto Ricans who have migrated to the United States, a significant number have returned to Puerto Rico, while others shuttle between Puerto Rico and the United States. These groups of people are identified as return migrants. Studies suggest that return migrant youth in Puerto Rico have had to make environmental and cultural adjustments…

  12. Scale Model Experiments on Sound Propagation From a Mach 2.5 Cold Nitrogen Jet Flowing Through a Rigid-Walled Duct With a J-Deflector

    NASA Technical Reports Server (NTRS)

    Kandula, Max; Vu, Bruce

    2003-01-01

    The Launch Systems Testbed (LST) represents the evolution of vibroacoustics research and development work performed at NASA John F. Kennedy Space Center (KSC) over the last 15 years. The LST is located at the Launch Equipment Test Facility (LETF) in the KSC industrial complex. The LETF is operated by Sierra Lobo, Inc., as a member of University-Affiliated Technology Development Contract (USTDC) to KSC Spaceport and Engineering and Technology Directorate (YA), with ASRC Aerospace Corporation as a the prime contractor. Trajectory Simulation Mechanism (TSM) is a major component of the LST, developed specifically to simulate nonstationary acoustic loads on launch pad structures, vehicles, and payloads. TSM enhances the capabilities within LST for simulating launch environments of future vehicles. The scaled launch environments will be used to predict the full-scale launch environment via an appropriate scaling procedure. Air Force Research Laboratory (AFRL) has tasked NASA KSC to perform a basic technology test program in support of developing a low-cost clean pad (incorporating passive mitigation techniques) for future launch vehicles. The overall goal of the program is to develop innovative launch exhaust management systems, which effectively reduce launch acoustic environment with innovative duct designs, while eliminating traditional sound suppression water systems. Passive techniques, such as nontraditional duct geometries, resonators, and diffusers, etc., will be investigated. The overall goals are to advance innovative concepts for a clean pad while developing ideas to reduce transmitted sound via investigation and modeling of jet exhaust acoustic and flow field characteristics. The series of tests outlined in this report represent baseline tests and are geared towards defining the acoustic load environment on the TSM pad for open and closed duct configurations. This report summarizes the cold jet acoustic testing for Mach 2.5 supersonic nitrogen jet issuing

  13. Sample Return Science

    NASA Astrophysics Data System (ADS)

    Williford, K. H.; Allwood, A.; Beegle, L. W.; Bhartia, R.; Flannery, D.; Hoffmann, A.; Mora, M. F.; Orbay, J.; Petrizzo, D. A.; Tuite, M. L., Jr.; Willis, P. A.

    2014-12-01

    The first clear identification of an ancient habitable environment on Mars by the Mars Science Laboratory (MSL) rover mission relied on a synthetic analytical approach combining orbital and surface imagery and spectroscopy with sophisticated sample acquisition and handling technology including a rotary percussive drill that provided powdered rock for bulk geochemical analysis [1]. The recent announcement of the instrument package for the proposed NASA Mars2020 rover mission, including micro x-ray fluorescence (PIXL) for elemental mapping as well as scanning ultraviolet laser fluorescence and Raman (SHERLOC) suggests a shift in emphasis of Mars surface science towards spatially resolved geochemical analysis that will support the selection and acquisition of samples for coring, caching, and possible return to Earth for further analysis. During a recent field expedition to investigate Archean and Proterozoic biosignatures in the Pilbara region of Western Australia, we deployed a dry, rotary percussive coring drill with a bit assembly analogous to that being considered for Mars2020. Six targets of varying age and lithology were sampled with the coring drill, and surrounding and adjacent rock samples were collected simultaneously. These samples were subsequently prepared and subsampled for bulk and in situ, spatially resolved analysis using conventional laboratory methods as well as the existing PIXL and SHERLOC platforms currently in development. Here we present new approaches and data from this integrated and ongoing program of "sample return science" designed to simulate, and eventually reduce risk associated with a long-term effort towards Mars sample return. [1] Grotzinger, J.P. et al. 2014. Science 343 DOI: 10.1126/science.1242777.

  14. Impaired pancreatic duct-cell growth in focal areas of regeneration after partial pancreatectomy in the adult Goto-Kakizaki rat, a spontaneous model of non-insulin dependent diabetes mellitus.

    PubMed

    Plachot, C; Portha, B

    2001-03-01

    The Paris colony of adult Goto-Kakizaki (GK/Par) rat, a genetic model of non-insulin dependent diabetes mellitus, is characterized by a restriction of the beta-cell mass and reduced beta-cell regeneration capacity. In order to have a better understanding of the impaired mechanism(s) leading to reduced beta-cell plasticity in the GK/Par rat, we have investigated duct-cell growth capacity following 90% pancreatectomy, a well-defined procedure leading in non-diabetic rats, to sequential duct proliferation and subsequent differentiation. To this aim, we have performed pancreatectomy in 8-10-week-old male normoglycaemic Wistar and diabetic GK rats. Duct-cell proliferation and apoptosis were evaluated at different time points: day 0 (D0), day 2 (D2), day 7 (D7) and day 14 (D14) after pancreatectomy. A transient wave of duct-cell proliferation was observed on D2 in both small and main ducts in the pancreatectomized Wistar rats. A similar increase occurred in the similarly treated GK rats, but to a higher extent as compared to the Wistar rats. Thereafter, duct-cell proliferation from main or small ducts returned to non-pancreatectomized values on D7 and remained at this level on D14 in both the Wistar and GK pancreatectomized groups. In the common pancreatic duct, the number of proliferative duct-cells was higher in GK rats compared to Wistar on D0. In both the operated Wistar and GK rats, duct-cell proliferation from the common pancreatic duct similarly decreased on D2. On D7 and D14, the same parameter returned to non-pancreatectomized values in the Wistar rats, while it was maintained lower in the GK rats as compared to the GK values on D0. In focal areas of regeneration, duct-cell proliferation was significantly lower in the pancreatectomized GK group compared to the age-related Wistar group on D7 (Wistar: 5.85+/-0.98%, GK: 3.02+/-0.69%; p < 0.01) and D14 (Wistar: 3.82+/-0.29%, GK: 2.62+/-0.27%; ns). Only a few apoptotic duct-cells were observed, with no difference

  15. 57. Building 105, another view of ion return RF balance ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    57. Building 105, another view of ion return RF balance tube system, and beginning of waveguide return connections to right of photograph; note bottoms of waveguide systems around circumference of scanner switch in upper part of photograph. - Clear Air Force Station, Ballistic Missile Early Warning System Site II, One mile west of mile marker 293.5 on Parks Highway, 5 miles southwest of Anderson, Anderson, Denali Borough, AK

  16. Mars sample return - Science

    NASA Technical Reports Server (NTRS)

    Blanchard, Douglas P.

    1988-01-01

    The possible scientific goals of a Mars sample return mission are reviewed, including the value of samples and the selection of sampling sites. The fundamental questions about Mars which could be studied using samples are examined, including planetary formation, differentiation, volcanism and petrogenesis, weathering, and erosion. Scenarios are presented for sample acquisition and analysis. Possible sampling methods and tools are discussed, including drilling techniques, types of rovers, and processing instruments. In addition, the possibility of aerocapture out of elliptical or circular orbit is considered.

  17. Titan Science Return Quantification

    NASA Technical Reports Server (NTRS)

    Weisbin, Charles R.; Lincoln, William

    2014-01-01

    Each proposal for a NASA mission concept includes a Science Traceability Matrix (STM), intended to show that what is being proposed would contribute to satisfying one or more of the agency's top-level science goals. But the information traditionally provided cannot be used directly to quantitatively compare anticipated science return. We added numerical elements to NASA's STM and developed a software tool to process the data. We then applied this methodology to evaluate a group of competing concepts for a proposed mission to Saturn's moon, Titan.

  18. 14 CFR 23.1103 - Induction system ducts.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Induction system ducts. 23.1103 Section 23.1103 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Powerplant Induction System § 23.1103 Induction system ducts....

  19. 14 CFR 23.1103 - Induction system ducts.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Induction system ducts. 23.1103 Section 23.1103 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Powerplant Induction System § 23.1103 Induction system ducts....

  20. Sound waves in two-dimensional ducts with sinusoidal walls

    NASA Technical Reports Server (NTRS)

    Nayfeh, A. H.

    1974-01-01

    The method of multiple scales is used to analyze the wave propagation in two-dimensional hard-walled ducts with sinusoidal walls. For traveling waves, resonance occurs whenever the wall wavenumber is equal to the difference of the wavenumbers of any two duct acoustic modes. The results show that neither of these resonating modes could occur without strongly generating the other.

  1. 11. VIEW OF A HEATING DUCT SITUATED SOUTHWEST OF THE ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    11. VIEW OF A HEATING DUCT SITUATED SOUTHWEST OF THE FAN HOUSE, ALONG THE MINE ROAD. THE BURNED RUINS OF THE MINE OFFICE ARE LOCATED ON THE FAR SIDE OF THE HEATING DUCT, TO THE NORTHWEST. - Tower Hill No. 2 Mine, Approximately 0.47 mile Southwest of intersection of Stone Church Road & Township Route 561, Hibbs, Fayette County, PA

  2. Duct thermal performance models for large commercial buildings

    SciTech Connect

    Wray, Craig P.

    2003-10-01

    Despite the potential for significant energy savings by reducing duct leakage or other thermal losses from duct systems in large commercial buildings, California Title 24 has no provisions to credit energy-efficient duct systems in these buildings. A substantial reason is the lack of readily available simulation tools to demonstrate the energy-saving benefits associated with efficient duct systems in large commercial buildings. The overall goal of the Efficient Distribution Systems (EDS) project within the PIER High Performance Commercial Building Systems Program is to bridge the gaps in current duct thermal performance modeling capabilities, and to expand our understanding of duct thermal performance in California large commercial buildings. As steps toward this goal, our strategy in the EDS project involves two parts: (1) developing a whole-building energy simulation approach for analyzing duct thermal performance in large commercial buildings, and (2) using the tool to identify the energy impacts of duct leakage in California large commercial buildings, in support of future recommendations to address duct performance in the Title 24 Energy Efficiency Standards for Nonresidential Buildings. The specific technical objectives for the EDS project were to: (1) Identify a near-term whole-building energy simulation approach that can be used in the impacts analysis task of this project (see Objective 3), with little or no modification. A secondary objective is to recommend how to proceed with long-term development of an improved compliance tool for Title 24 that addresses duct thermal performance. (2) Develop an Alternative Calculation Method (ACM) change proposal to include a new metric for thermal distribution system efficiency in the reporting requirements for the 2005 Title 24 Standards. The metric will facilitate future comparisons of different system types using a common ''yardstick''. (3) Using the selected near-term simulation approach, assess the impacts of

  3. Reactive control of subsonic axial fan noise in a duct.

    PubMed

    Liu, Y; Choy, Y S; Huang, L; Cheng, L

    2014-10-01

    Suppressing the ducted fan noise at low frequencies without varying the flow capacity is still a technical challenge. This study examines a conceived device consisting of two tensioned membranes backed with cavities housing the axial fan for suppression of the sound radiation from the axial fan directly. The noise suppression is achieved by destructive interference between the sound fields from the axial fan of a dipole nature and sound radiation from the membrane via vibroacoustics coupling. A two-dimensional model with the flow effect is presented which allows the performance of the device to be explored analytically. The air flow influences the symmetrical behavior and excites the odd in vacuo mode response of the membrane due to kinematic coupling. Such an asymmetrical effect can be compromised with off-center alignment of the axial fan. Tension plays an important role to sustain the performance to revoke the deformation of the membrane during the axial fan operation. With the design of four appropriately tensioned membranes covered by a cylindrical cavity, the first and second blade passage frequencies of the axial fan can be reduced by at least 20 dB. The satisfactory agreement between experiment and theory demonstrates that its feasibility is practical. PMID:25324066

  4. An electronically tunable duct silencer using dielectric elastomer actuators.

    PubMed

    Lu, Zhenbo; Godaba, Hareesh; Cui, Yongdong; Foo, Choon Chiang; Debiasi, Marco; Zhu, Jian

    2015-09-01

    A duct silencer with tunable acoustic characteristics is presented in this paper. Dielectric elastomer, a smart material with lightweight, high elastic energy density and large deformation under high direct current/alternating current voltages, was used to fabricate this duct silencer. The acoustic performances and tunable mechanisms of this duct silencer were experimentally investigated. It was found that all the resonance peaks of this duct silencer could be adjusted using external control signals without any additional mechanical part. The physics of the tunable mechanism is further discussed based on the electro-mechanical interactions using finite element analysis. The present promising results also provide insight into the appropriateness of the duct silencer for possible use as next generation acoustic treatment device to replace the traditional acoustic treatment. PMID:26428819

  5. Heat Transfer in Conical Corner and Short Superelliptical Transition Ducts

    NASA Technical Reports Server (NTRS)

    Poinsatte, Philip; Thurman, Douglas; Hippensteele, Steven

    2008-01-01

    Local surface heat transfer measurements were experimentally mapped using a transient liquid-crystal heat-transfer technique on the surface of two circular-to-rectangular transition ducts. One has a transition cross section defined by conical corners (Duct 1) and the other by an elliptical equation with changing coefficients (Duct 2). Duct 1 has a length-to-diameter ratio of 0.75 and an exit plane aspect ratio of 1.5. Duct 2 has a length-to-diameter ratio of 1.0 and an exit plane aspect ratio of 2.9. Test results are reported for various inlet-diameter-based Reynolds numbers ranging from 0.45 106 to 2.39 106 and two freestream turbulence intensities of about 1 percent, which is typical of wind tunnels, and up to 16 percent, which may be more typical of real engine conditions.

  6. Anicteric early bile duct carcinoma detection with magnetic resonance cholangiopancreatography.

    PubMed

    Oshikiri, Taro; Morita, Takayuki; Fujita, Miyoshi; Miyasaka, Yuji; Senmaru, Naoto; Yamada, Hidehisa; Kondo, Satoshi; Katoh, Hiroyuki

    2005-01-01

    The poor prognosis of extrahepatic bile duct carcinoma makes early detection and diagnosis essential for positive patient outcomes. We describe 2 cases of jaundice-free early extrahepatic bile duct carcinoma detected by magnetic resonance cholangiopancreatography. Extrahepatic bile duct carcinoma was discovered incidentally in patient 1 by magnetic resonance cholangiopancreatography during evaluation of a gallbladder stone. In patient 2, extrahepatic bile duct carcinoma was found during a routine health maintenance exam. Both patients underwent radical surgical intervention. Both patient 1 and 2 have remained in good health for over one year, 3.5 and one year, respectively, and have not exhibited any signs or symptoms of relapse or cancer recurrence. Based on these cases, it appears that magnetic resonance cholangiopancreatography can play a significant role in the early detection of extrahepatic bile duct carcinoma and improve disease prognosis. PMID:15816438

  7. Extravasation Mucocele Arising from a Lingual Thyroglossal Duct Remnant

    PubMed Central

    Nakahira, Mitsuhiko; Nakatani, Hiroaki

    2015-01-01

    Although a thyroglossal duct cyst is a congenital anomaly, it can also appear in adults. Despite the presence of embryological remnants, it is still unclear why the cyst should suddenly develop later in life. We report a case of a 46-year-old male with an extravasation mucocele arising from a long-standing lingual thyroglossal duct remnant. MRI demonstrated a lingual cystic lesion near the hyoid bone associated with a suprahyoid tract-like structure masquerading as a thyroglossal duct cyst. However, histopathological examination demonstrated a mucocele secondary to a rupture of a thyroglossal duct remnant with numerous intramural heterotopic salivary glands. We propose a new mechanism of an acquired cystic formation of this congenital disease that excessive production of mucus from heterotopic salivary glands and a physical trauma such as swallowing may lead to extravasation of mucus from the thyroglossal duct. PMID:25861502

  8. Extravasation mucocele arising from a lingual thyroglossal duct remnant.

    PubMed

    Nakahira, Mitsuhiko; Nakatani, Hiroaki

    2015-01-01

    Although a thyroglossal duct cyst is a congenital anomaly, it can also appear in adults. Despite the presence of embryological remnants, it is still unclear why the cyst should suddenly develop later in life. We report a case of a 46-year-old male with an extravasation mucocele arising from a long-standing lingual thyroglossal duct remnant. MRI demonstrated a lingual cystic lesion near the hyoid bone associated with a suprahyoid tract-like structure masquerading as a thyroglossal duct cyst. However, histopathological examination demonstrated a mucocele secondary to a rupture of a thyroglossal duct remnant with numerous intramural heterotopic salivary glands. We propose a new mechanism of an acquired cystic formation of this congenital disease that excessive production of mucus from heterotopic salivary glands and a physical trauma such as swallowing may lead to extravasation of mucus from the thyroglossal duct. PMID:25861502

  9. The surface evaporative duct height product: An evaluation

    NASA Astrophysics Data System (ADS)

    Thompson, William T.

    1987-12-01

    The existence of a surface evaporative duct has many serious operational implications. One of the most serious and obvious implications is that the extended range of the radar will allow distant hostile units to detect the radar (and to be detected by the radar). Thus, the existence of a surface evaporative duct is an important component of the decision on whether or not to radiate. Another consequence of the duct is that a radar hole will exist between the top of the duct and the base of the lobes unaffected by the duct (see figure 1). Hostile aircraft or missiles will thus be able to approach the radar undetected. Conversely, knowledge of the refractivity profile in the vicinity of enemy radars can be turned to tactical advantage.

  10. A new evaporation duct climatology over the South China Sea

    NASA Astrophysics Data System (ADS)

    Shi, Yang; Yang, Kunde; Yang, Yixin; Ma, Yuanliang

    2015-10-01

    The climatology of evaporation ducts is important for shipborne electromagnetic system design and application. The evaporation duct climatology that is currently used for such applications was developed in the mid 1980s; this study presents efforts to improve it over the South China Sea (SCS) by using a state-of-the-art evaporation duct model and an improved meteorology dataset. This new climatology provides better evaporation duct height (EDH) data over the SCS, at a higher resolution of 0.312°×0.313°. A comparison between the new climatology and the old one is performed. The monthly average EDH in the new climatology is between 10 and 12 m over the SCS, higher than that in the old climatology. The spatiotemporal characteristics of the evaporation duct over the SCS in different months are analyzed in detail, based on the new climatology.

  11. Regeneratively cooled transition duct with transversely buffered impingement nozzles

    SciTech Connect

    Morrison, Jay A; Lee, Ching-Pang; Crawford, Michael E

    2015-04-21

    A cooling arrangement (56) having: a duct (30) configured to receive hot gases (16) from a combustor; and a flow sleeve (50) surrounding the duct and defining a cooling plenum (52) there between, wherein the flow sleeve is configured to form impingement cooling jets (70) emanating from dimples (82) in the flow sleeve effective to predominately cool the duct in an impingement cooling zone (60), and wherein the flow sleeve defines a convection cooling zone (64) effective to cool the duct solely via a cross-flow (76), the cross-flow comprising cooling fluid (72) exhausting from the impingement cooling zone. In the impingement cooling zone an undimpled portion (84) of the flow sleeve tapers away from the duct as the undimpled portion nears the convection cooling zone. The flow sleeve is configured to effect a greater velocity of the cross-flow in the convection cooling zone than in the impingement cooling zone.

  12. Rhinosporidiosis in the parotid duct: a rare case report.

    PubMed

    Panda, Swagatika; Lenka, Sthitaprajna; Padhiary, Subrat K; Sahoo, Sujit R; Srivastava, Gunjan

    2013-11-01

    Endemic to South India and Sri Lanka, Rhinosporidiosis is a chronic granulomatous infection caused by an agent of uncertain taxonomy: Rhinosporidium seeberi. Although it commonly manifests as a proliferative nasal lesion, many cases of Rhinosporidiosis have been reported where it has appeared as an extranasal lesion. The reported extranasal sites include the eye, ear, trachea, and parotid duct. However, the involvement of the parotid duct is quite rare, even among extranasal sites. The case presented is an adult female from the non-endemic zone of East India with a proliferative mass in the parotid duct. Although Rhinosporidiosis was not taken into consideration in the clinical differential diagnosis, eventual histopathological diagnosis confirmed Rhinosporidiosis. As this appears to be the second case of Rhinosporidiosis in the parotid duct in East India in 4 years, we encourage clinicians to be flexible in the differential diagnosis of proliferative growth in the parotid duct, even in those from non-endemic areas. PMID:23371913

  13. Analysis of pressure spectra measurements in a ducted combustion system. Ph.D. Thesis - Toledo Univ.

    NASA Technical Reports Server (NTRS)

    Miles, J. H.

    1980-01-01

    Combustion noise propagation in an operating ducted liquid fuel combustion system is studied in relation to the development of combustion noise prediction and suppression techniques. The presence of combustor emissions in the duct is proposed as the primary mechanism producing the attenuation and dispersion of combustion noise propagating in an operating liquid fuel combustion system. First, a complex mathematical model for calculating attenuation and dispersion taking into account mass transfer, heat transfer, and viscosity effects due to the presence of liquid fuel droplets or solid soot particles is discussed. Next, a simpler single parameter model for calculating pressure auto-spectra and cross-spectra which takes into account dispersion and attenuation due to heat transfer between solid soot particles and air is developed. Then, auto-spectra and cross-spectra obtained from internal pressure measurements in a combustion system consisting of a J-47 combustor can, a spool piece, and a long duct are presented. Last, analytical results obtained with the single parameter model are compared with the experimental measurements. The single parameter model results are shown to be in excellent agreement with the measurements.

  14. MSFC hot air collectors. Phase 1: Test report

    NASA Technical Reports Server (NTRS)

    Losey, R.

    1977-01-01

    A development test program of 3 hot air flat plate solar collectors is described in detail. The pressure drop versus flow rate performance characteristics for these collectors, mounted in series, was determined under 14 different test conditions each of which was characterized by a unique combination of inlet air temperature and air flow rate. Characteristics of inlet, exit and transfer ducts of these collectors were also determined during this testing. The test results indicate that significant pressure drop occurs at air flow rates greater than 150 standard cubic feet per minute and this drop is not heavily dependent upon inlet air temperature; and inlet, exit and transfer duct characteristics differ sufficiently to suggest that system performance may be enhanced through careful design of each type of duct individually.

  15. New Insights for Improving the Designs of Flexible Duct Junction Boxes (Fact Sheet)

    SciTech Connect

    Not Available

    2014-01-01

    IBACOS explored the relationships between pressure and physical configurations of flexible duct junction boxes by using computational fluid dynamics (CFD) simulations to predict individual box parameters and total system pressure, thereby ensuring improved HVAC performance. Current Air Conditioning Contractors of America (ACCA) guidance (Group 11, Appendix 3, ACCA Manual D, Rutkowski 2009) allows for unconstrained variation in the number of takeoffs, box sizes, and takeoff locations. The only variables currently used in selecting an equivalent length (EL) are velocity of air in the duct and friction rate, given the first takeoff is located at least twice its diameter away from the inlet. This condition does not account for other factors impacting pressure loss across these types of fittings. For each simulation, the IBACOS team converted pressure loss within a box to an EL to compare variation in ACCA Manual D guidance to the simulated variation. IBACOS chose cases to represent flows reasonably correlating to flows typically encountered in the field and analyzed differences in total pressure due to increases in number and location of takeoffs, box dimensions, and velocity of air, and whether an entrance fitting is included. The team also calculated additional balancing losses for all cases due to discrepancies between intended outlet flows and natural flow splits created by the fitting. In certain asymmetrical cases, the balancing losses were significantly higher than symmetrical cases where the natural splits were close to the targets. Thus, IBACOS has shown additional design constraints that can ensure better system performance.

  16. Low frequency sound attenuation in a flow duct using a thin slow sound material

    NASA Astrophysics Data System (ADS)

    Aurégan, Yves; Farooqui, Maaz; Groby, Jean-Philippe

    2016-05-01

    We present a thin subwavelength material that can be flush mounted to a duct and which gives a large wide band attenuation at remarkably low frequencies in air flow channels. To decrease the material thickness, the sound is slowed in the material using folded side branch tubes. The impedance of the material is compared to the optimal value, which differs greatly from the characteristic impedance. In particular, the viscous and thermal effects have to be very small to have high transmission losses. Grazing flow on this material increases the losses at the interface between the flow and the material.

  17. Analysis of an advanced ducted propeller subsonic inlet

    NASA Technical Reports Server (NTRS)

    Iek, Chanthy; Boldman, Donald R.; Ibrahim, Mounir

    1992-01-01

    A time marching Navier-Stokes code called PARC (PARC2D for 2-D/axisymmetric and PARC3D for 3-D flow simulations) was validated for an advanced ducted propeller (ADP) subsonic inlet. The code validation for an advanced ducted propeller (ADP) subsonic inlet. The code validation was implemented for a non-separated flow condition associated with the inlet operating at angles-of-attack of 0 and 25 degrees. The inlet test data were obtained in the 9 x 15 ft Low Speed Wind Tunnel at NASA Lewis Research Center as part of a cooperative study with Pratt and Whitney. The experimental study focused on the ADP inlet performance for take-off and approach conditions. The inlet was tested at a free stream Mach number of 0.2, at angles-of-attack between O and 35 degrees, and at a maximum propeller speed of 12,000 RPM which induced a corrected air flow rate of about 46 lb/sec based on standard day conditions. The computational grid and flow boundary conditions (BC) were based on the actual inlet geometry and the funnel flow conditions. At the propeller face, two types of BC's were applied: a mass flow BC and a fixed flow properties BC. The fixed flow properties BC was based on a combination of data obtained from the experiment and calculations using a potential flow code. Comparison of the computational results with the test data indicates that the PARC code with the propeller face fixed flow properties BC provided a better prediction of the inlet surface static pressures than the predictions when the mass flow BC was used. For an angle-of-attack of 0 degrees, the PARC2D code with the propeller face mass flow BC provided a good prediction of inlet static pressures except in the region of high pressure gradient. With the propeller face fixed flow properties BC, the PARC2D code provided a good prediction of the inlet static pressures. For an angle-of-attack of 25 degrees with the mass flow BC, the PARC3D code predicted statis pressures which deviated significantly from the test data

  18. Acoustic propagation in rigid ducts with blockage

    NASA Technical Reports Server (NTRS)

    El-Raheb, M.; Wagner, P.

    1982-01-01

    Acoustic levitation has been suggested for moving nonmagnetic material in furnaces for heat processing in space experiments. Basically, acoustic standing waves under resonant conditions are excited in the cavity of the furnace while the material blockage is located at a pressure node and thus at a maximum gradient. The position of the blockage is controlled by displacing the node as a result of frequency change. The present investigation is concerned with the effect of blockage on the longitudinal and transverse resonances of a cylindrical cavity, taking into account the results of a one-dimensional and three-dimensional (3-D) analysis. Based on a Green's function surface element method, 3-D analysis is tested experimentally and proved to be accurate over a wide range of geometric parameters and boundary shapes. The shift in resonance depends on the change in pressure gradient and duct shortening caused by the blockage.

  19. Technology readiness for advanced ducted engines

    SciTech Connect

    Eckardt, D.; Brines, G.L.

    1989-01-01

    The Advanced Ducted Engines (ADEs) currently undergoing development for next-generation passenger aircraft typically possess bypass ratios of the order of 12-25 and specific fuel consumption figures 12-17 percent lower than current advanced turbofans. An extensive technology-readiness program has been mounted on behalf of ADE design definition over the last two years, encompassing among its concerns aircraft/engine-installation interference, low pressure-ratio fan aerodynamics, fan/nacelle interactions (including windmilling and thrust-reversal), acoustic characteristics, transonic-drive turbines, and slender nacelle aerodynamic and mechanical design. Both turbine-driven and geared ADE fans, which may be of single-rotating or contrarotating type, are discussed. 5 refs.

  20. ADAM: An Axisymmetric Duct Aeroacoustic Modeling system

    NASA Astrophysics Data System (ADS)

    Abrahamson, A. L.

    1983-01-01

    An interconnected system of computer programs for analyzing the propagation and attenuation of sound in aeroengine ducts containing realistic compressible subsonic mean flows, ADAM was developed primarily for research directed towards the reduction of noise emitted from turbofan aircraft engines. The two basic components are a streamtube curvature program for determination of the mean flow, and a finite element code for solution of the acoustic propagation problem. The system, which has been specifically tailored for ease of use, is presently installed at NASA Langley Reseach Center on a Control Data Cyber 175 Computer under the NOS Operating system employing a Tektronix terminal for interactive graphics. The scope and organization of the ADAM system is described. A users guide, examples of input data, and results for selected cases are included.

  1. Live 3D image overlay for arterial duct closure with Amplatzer Duct Occluder II additional size.

    PubMed

    Goreczny, Sebstian; Morgan, Gareth J; Dryzek, Pawel

    2016-03-01

    Despite several reports describing echocardiography for the guidance of ductal closure, two-dimensional angiography remains the mainstay imaging tool; three-dimensional rotational angiography has the potential to overcome some of the drawbacks of standard angiography, and reconstructed image overlay provides reliable guidance for device placement. We describe arterial duct closure solely from venous approach guided by live three-dimensional image overlay. PMID:26358032

  2. Experimental and analytical methods for the determination of connected-pipe ramjet and ducted rocket internal performance

    NASA Astrophysics Data System (ADS)

    1994-07-01

    Connected-pipe, subsonic combustion ramjet and ducted rocket performance determination procedures used by the NATO countries have been reviewed and evaluated. A working document has been produced which provides recommended methods for reporting test results and delineates the parameters that are required to be measured. Explanations and detailed numerical examples are presented covering the determination of both theoretical and experimental performances, the use of air heaters and uncertainty and error analysis.

  3. Returning Samples from Enceladus

    NASA Astrophysics Data System (ADS)

    Tsou, P.; Kanik, I.; Brownlee, D.; McKay, C.; Anbar, A.; Glavin, D.; Yano, H.

    2012-12-01

    From the first half century of space exploration, we have obtained samples only from the Moon, comet Wild 2, the Solar Wind and the asteroid Itokawa. The in-depth analyses of these samples in terrestrial laboratories have yielded profound knowledge that could not have been obtained without the returned samples. While obtaining samples from Solar System bodies is crucial science, it is rarely done due to cost and complexity. Cassini's discovery of geysers on Enceladus and organic materials, indicate that there is an exceptional opportunity and science rational to do a low-cost flyby sample return mission, similar to what was done by the Stardust. The earliest low cost possible flight opportunity is the next Discovery Mission [Tsou et al 2012]. Enceladus Plume Discovery - While Voyager provided evidence for young surfaces on Enceladus, the existence of Enceladus plumes was discovered by Cassini. Enceladus and comets are the only known solar system bodies that have jets enabling sample collection without landing or surface contact. Cassini in situ Findings -Cassini's made many discoveries at Saturn, including the break up of large organics in the plumes of Enceladus. Four prime criteria for habitability are liquid water, a heat source, organics and nitrogen [McKay et al. 2008, Waite et al. 2009, Postberg et al. 2011]. Out of all the NASA designated habitability targets, Enceladus is the single body that presents evidence for all four criteria. Significant advancement in the exploration of the biological potential of Enceladus can be made on returned samples in terrestrial laboratories where the full power of state-of-the-art laboratory instrumentation and procedures can be used. Without serious limits on power, mass or even cost, terrestrial laboratories provide the ultimate in analytical capability, adaptability, reproducibility and reliability. What Questions can Samples Address? - Samples collected from the Enceladus plume will enable a thorough and replicated

  4. Return to Space

    NASA Technical Reports Server (NTRS)

    1989-01-01

    This video documents the preparations for Shuttle Flight STS-26 with Shuttle Discovery, NASA's return to manned space flight after the Challenger disaster. Footage and descriptions document such changes to the new Shuttle as new joints, improved insulation, and added O-rings to the solid rocket boosters; new safety hardware and procedures such as parachute and sidewire evacuations during liftoff, and new pressure suits; modified landing gear, brakes, and nose wheel steering, as well as a modified landing runway. Also profiled are the 5 member crew of all veteran Shuttle astronauts, the TDRS 3 Satellite to be released from the cargo bay in orbit, and 11 commercial and student experiments to be performed during the mission.

  5. Dealing with returned manuscripts.

    PubMed

    Peh, W C G; Ng, K H

    2009-11-01

    It is useful for authors to learn to deal with returned manuscripts with a rejection decision or a request for revision. Common reasons for rejection include contents outside the scope of the journal or inappropriate for the journal, incomplete submission, poor methodology, faulty experimental design, major flaws in the interpretation of results, extremely poor writing, and duplicated or plagiarised work. Authors should use the editor's and reviewers' comments to improve their manuscripts and resubmit elsewhere. Common reasons for revision requests include minor faults in the methodology, minor inaccuracies in data, inconsistencies among different sections of the manuscript, faulty deductions, data that do not support the conclusions, excessive data or text, poor or excessive illustrations, and poor but salvageable writing. A request for revision should be viewed positively, as it means that there is a possibility that the manuscript may still be potentially publishable, provided that all the editor's and reviewers' comments are addressed. PMID:19960157

  6. Return to space

    NASA Astrophysics Data System (ADS)

    1989-08-01

    This video documents the preparations for Shuttle Flight STS-26 with Shuttle Discovery, NASA's return to manned space flight after the Challenger disaster. Footage and descriptions document such changes to the new Shuttle as new joints, improved insulation, and added O-rings to the solid rocket boosters; new safety hardware and procedures such as parachute and sidewire evacuations during liftoff, and new pressure suits; modified landing gear, brakes, and nose wheel steering, as well as a modified landing runway. Also profiled are the 5 member crew of all veteran Shuttle astronauts, the TDRS 3 Satellite to be released from the cargo bay in orbit, and 11 commercial and student experiments to be performed during the mission.

  7. EFFECT OF CENTRAL FANS AND IN-DUCT FILTERS ON DEPOSITION RATES OF ULTRAFINE AND FINE PARTICLES IN AN OCCUPIED TOWNHOUSE

    EPA Science Inventory

    Airborne particles are implicated in morbidity and mortality of certain high-risk subpopulations. Exposure to particles occurs mostly indoors, where a main removal mechanism is deposition to surfaces. Deposition can be affected by the use of forced- air circulation through duct...

  8. Negative space filling and 3D reconstruction of histological sections demonstrates differences in volumes of vessels and ducts within portal tracts of canine livers

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Visualizing areas of tissue that are occupied by air or liquid can provide a unique perspective on the relationships between various spaces within the tissue. The portal tracts of liver tissue are an example of such a space since the liver contains several vessels and ducts in various patterns of i...

  9. Register Closing Effects on Forced Air Heating System Performance

    SciTech Connect

    Walker, Iain S.

    2003-11-01

    Closing registers in forced air heating systems and leaving some rooms in a house unconditioned has been suggested as a method of quickly saving energy for California consumers. This study combined laboratory measurements of the changes in duct leakage as registers are closed together with modeling techniques to estimate the changes in energy use attributed to closing registers. The results of this study showed that register closing led to increased energy use for a typical California house over a wide combination of climate, duct leakage and number of closed registers. The reduction in building thermal loads due to conditioning only a part of the house was offset by increased duct system losses; mostly due to increased duct leakage. Therefore, the register closing technique is not recommended as a viable energy saving strategy for California houses with ducts located outside conditioned space. The energy penalty associated with the register closing technique was found to be minimized if registers furthest from the air handler are closed first because this tends to only affect the pressures and air leakage for the closed off branch. Closing registers nearer the air handler tends to increase the pressures and air leakage for the whole system. Closing too many registers (more than 60%) is not recommended because the added flow resistance severely restricts the air flow though the system leading to safety concerns. For example, furnaces may operate on the high-limit switch and cooling systems may suffer from frozen coils.

  10. Duct Leakage Modeling in EnergyPlus and Analysis of Energy Savings from Implementing SAV with InCITeTM

    SciTech Connect

    Wray, Craig; Sherman, Max

    2010-03-01

    This project addressed two significant deficiencies in air-handling systems for large commercial building: duct leakage and duct static pressure reset. Both constitute significant energy reduction opportunities for these buildings. The overall project goal is to bridge the gaps in current duct performance modeling capabilities, and to expand our understanding of air-handling system performance in California large commercial buildings. The purpose of this project is to provide technical support for the implementation of a duct leakage modeling capability in EnergyPlus, to demonstrate the capabilities of the new model, and to carry out analyses of field measurements intended to demonstrate the energy saving potential of the SAV with InCITeTM duct static pressure reset (SPR) technology. A new duct leakage model has been successfully implemented in EnergyPlus, which will enable simulation users to assess the impacts of leakage on whole-building energy use and operation in a coupled manner. This feature also provides a foundation to support code change proposals and compliance analyses related to Title 24 where duct leakage is an issue. Our example simulations continue to show that leaky ducts substantially increase fan power: 10percent upstream and 10percent downstream leakage increases supply fan power 30percent on average compared to a tight duct system (2.5percent upstream and 2.5percent downstream leakage). Much of this increase is related to the upstream leakage rather than to the downstream leakage. This does not mean, however, that downstream leakage is unimportant. Our simulations also demonstrate that ceiling heat transfer is a significant effect that needs to be included when assessing the impacts of duct leakage in large commercial buildings. This is not particularly surprising, given that ?ceiling regain? issues have already been included in residential analyses as long as a decade ago (e.g., ASHRAE Standard 152); mainstream simulation programs that are

  11. Generation of Higher Order Modes in a Rectangular Duct

    NASA Technical Reports Server (NTRS)

    Gerhold, Carl H.; Cabell, Randolph H.; Brown, Donald E.

    2004-01-01

    Advanced noise control methodologies to reduce sound emission from aircraft engines take advantage of the modal structure of the noise in the duct. This noise is caused by the interaction of rotor wakes with downstream obstructions such as exit guide vanes. Mode synthesis has been accomplished in circular ducts and current active noise control work has made use of this capability to cancel fan noise. The goal of the current effort is to examine the fundamental process of higher order mode propagation through an acoustically treated, curved duct. The duct cross-section is rectangular to permit greater flexibility in representation of a range of duct curvatures. The work presented is the development of a feedforward control system to generate a user-specified modal pattern in the duct. The multiple-error, filtered-x LMS algorithm is used to determine the magnitude and phase of signal input to the loudspeakers to produce a desired modal pattern at a set of error microphones. Implementation issues, including loudspeaker placement and error microphone placement, are discussed. Preliminary results from a 9-3/8 inch by 21 inch duct, using 12 loudspeakers and 24 microphones, are presented. These results demonstrate the ability of the control system to generate a user-specified mode while suppressing undesired modes.

  12. Modeling low elevation GPS signal propagation in maritime atmospheric ducts

    NASA Astrophysics Data System (ADS)

    Zhang, Jinpeng; Wu, Zhensen; Wang, Bo; Wang, Hongguang; Zhu, Qinglin

    2012-05-01

    Using the parabolic wave equation (PWE) method, we model low elevation GPS L1 signal propagation in maritime atmospheric ducts. To consider sea surface impedance, roughness, and the effects of earth's curvature, we propose a new initial field model for the GPS PWE split-step solution. On the basis of the comparison between the proposed model and the conventional initial field model for a smooth, perfectly conducting sea surface on a planar earth, we conclude that both the amplitude and phase of the initial field are influenced by surface impedance and roughness, and that the interference behavior between direct and reflected GPS rays is affected by earth's curvature. The performance of the proposed model is illustrated with examples of low elevation GPS L1 signal propagation in three types of ducts: an evaporation duct, a surface-based duct, and an elevated duct. The GPS PWE is numerically implemented using the split-step discrete mixed Fourier transform algorithm to enforce impedance-type boundary conditions at the rough sea surface. Because the GPS signal is right hand circularly polarized, we calculate its power strength by combining the propagation predictions of the horizontally and the vertically polarized components. The effects of the maritime atmospheric ducts on low elevation GPS signal propagation are demonstrated according to the presented examples, and the potential applications of the GPS signals affected by ducts are discussed.

  13. Remnant cystic duct adenocarcinoma presenting as gastric outlet obstruction

    PubMed Central

    Lo, Samuel Tsoon Wuan; Cheng, Yue; Cheung, Frances; Tang, Chung Ngai

    2016-01-01

    Only a few case reports of remnant cystic duct carcinoma exist. The presented case of remnant cystic duct carcinoma with invasion to pylorus and bulbus of duodenum leading to gastric outlet obstruction was the first of its kind. We reviewed all cases of remnant cystic duct carcinoma that we found in the literature and summarized its definition, presentation, extent of invasion and clinical outcome after operation. The diagnosis can be difficult due to the rarity of disease, locally advanced nature of disease and distorted postoperative anatomy. A high index of suspicion can increase the likelihood of a preoperative diagnosis. PMID:27154747

  14. Finite-amplitude waves in cylindrical lined ducts

    NASA Technical Reports Server (NTRS)

    Nayfeh, A. H.; Tsai, M.-S.

    1974-01-01

    A second-order uniformly valid expansion is obtained for nonlinear waves propagating in a cylindrical duct lined with a point-reacting acoustic material that consists of a porous sheet followed by honey-comb cavities and backed by the impervious walls of the duct. The effect of the liner is taken into account by coupling the waves in the duct with those in the liner. As in the two-dimensional case, the nonlinearity increases the attenuation rate at all frequencies except in narrow bandwidths around the resonant frequencies, irrespective of the geometrical dimensions of the liner or the acoustic properties of the porous sheet.

  15. Modal density function and number of propagating modes in ducts

    NASA Technical Reports Server (NTRS)

    Rice, E. J.

    1976-01-01

    Often raised questions in duct sound propagation studies involve the total number of propagating modes, the number of propagating radial modes for a particular spinning lobe number, and the number of modes possible between two given values of cutoff ratio or eigenvalue. These questions can be answered approximately by using the modal distribution function which is the integral of the modal density function for ducts in a manner similar to that previously published for architectural acoustics. The modal density functions are derived for rectangular and circular ducts with a uniform steady flow. Results from this continuous theory are compared to the actual (discrete) modal distributions.

  16. Millimetre-wave propagation in the evaporation duct

    NASA Astrophysics Data System (ADS)

    Levy, M. F.; Craig, K. H.

    1990-03-01

    Recent developments in propagation modeling based on the Parabolic Equation Method allow the forecasting of two-dimensional antenna coverage diagrams at millimeter wavelengths, in a dispersive atmosphere with arbitrary two-dimensional variation of the refractive index. The model was applied successfully to mm-wave propagation in the evaporation duct. The evaporation duct height is not sufficient to characterize mm-wave propagation, and information on the water vapor content is essential for the correct modeling of atmospheric absorption. Turbulence simulations were carried out, showing marked scintillation, effects in the evaporation duct. The method can be applied to arbitrary refractivity spectra, and gives a complete numerical description of the field statistics.

  17. Duplicated extrahepatic bile duct identified following cholecystectomy injury

    PubMed Central

    Hoepfner, Lauren; Sweeney, Mary Katherine; White, Jared A.

    2016-01-01

    Though variations of intrahepatic biliary anatomy are quite common, duplication of the extrahepatic biliary system is extremely rare and reported infrequently in the literature. Laparoscopic cholecystectomy is one of the most common general surgery procedures performed. Unfortunately, iatrogenic bile duct injuries can contribute to significant morbidity including hospital readmissions, infectious complications and death. Anomalous extrahepatic biliary anatomy may be one of the factors, which increases the likelihood of bile duct injury during laparoscopic cholecystectomy. We present a case of an iatrogenic bile duct injury that occurred during a laparoscopic cholecystectomy, in which a duplicated extrahepatic biliary system was identified intraoperatively during the definitive operative repair. PMID:27141049

  18. Transition duct with late injection in turbine system

    SciTech Connect

    LeBegue, Jeffrey Scott; Pentecost, Ronnie Ray; Flanagan, James Scott; Kim, Won -Wook; McMahan, Kevin Weston

    2015-09-15

    A system for supplying an injection fluid to a combustor is disclosed. The system includes a transition duct comprising an inlet, an outlet, and a passage extending between the inlet and the outlet and defining a longitudinal axis, a radial axis, and a tangential axis. The outlet of the transition duct is offset from the inlet along the longitudinal axis and the tangential axis. The passage defines a combustion chamber. The system further includes a tube providing fluid communication for the injection fluid to flow through the transition duct and into the combustion chamber.

  19. Validation of the criteria for initiating the cleaning of heating, ventilation, and air-conditioning (HVAC) ductwork under real conditions.

    PubMed

    Lavoie, Jacques; Marchand, Geneviève; Cloutier, Yves; Lavoué, Jérôme

    2011-08-01

    Dust accumulation in the components of heating, ventilation, and air-conditioning (HVAC) systems is a potential source of contaminants. To date, very little information is available on recognized methods for assessing dust buildup in these systems. The few existing methods are either objective in nature, involving numerical values, or subjective in nature, based on experts' judgments. An earlier project aimed at assessing different methods of sampling dust in ducts was carried out in the laboratories of the Institut de recherche Robert-Sauvé en santé et en sécurité du travail (IRSST). This laboratory study showed that all the sampling methods were practicable, provided that a specific surface-dust cleaning initiation criterion was used for each method. However, these conclusions were reached on the basis of ideal conditions in a laboratory using a reference dust. The objective of this present study was to validate these laboratory results in the field. To this end, the laboratory sampling templates were replicated in real ducts and the three sampling methods (the IRSST method, the method of the U.S. organization National Air Duct Cleaner Association [NADCA] and that of the French organization Association pour la Prévention et l'Étude de la Contamination [ASPEC]) were used simultaneously in a statistically representative number of systems. The air return and supply ducts were also compared. Cleaning initiation criteria under real conditions were found to be 6.0 mg/100 cm(2) using the IRSST method, 2.0 mg/100 cm(2) using the NADCA method, and 23 mg/100 cm(2) using the ASPEC method. In the laboratory study, the criteria using the same methods were 6.0 for the IRSST method, 2.0 for the NADCA method, and 3.0 for the ASPEC method. The laboratory criteria for the IRSST and NADCA methods were therefore validated in the field. The ASPEC criterion was the only one to change. The ASPEC method therefore allows for the most accurate evaluation of dust accumulation in HVAC

  20. 11. VIEW OF A SITE RETURN WEAPONS COMPONENT. SITE RETURNS ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    11. VIEW OF A SITE RETURN WEAPONS COMPONENT. SITE RETURNS WERE NUCLEAR WEAPONS SHIPPED TO THE ROCKY FLATS PLANT FROM THE NUCLEAR WEAPON STOCKPILE FOR RETIREMENT, TESTING, OR UPGRADING. FISSILE MATERIALS (PLUTONIUM, URANIUM, ETC.) AND RARE MATERIALS (BERYLLIUM) WERE RECOVERED FOR REUSE, AND THE REMAINDER WAS DISPOSED. (8/7/62) - Rocky Flats Plant, Plutonium Fabrication, Central section of Plant, Golden, Jefferson County, CO

  1. Christmas Island birds returning

    NASA Astrophysics Data System (ADS)

    Six months after their mass exodus, birds are beginning to return to Christmas Island. Roughly 17 million birds, almost the entire adult bird population, either perished or fled their mid-Pacific atoll home last autumn, leaving behind thousands of nestlings to starve (Eos, April 5, 1983, p. 131). It is believed that the strong El Niño altered the ecology of the surrounding waters and forced the birds to flee. Christmas Island is the world's largest coral atoll.“Ocean and atmosphere scientists are unsure of future directions for the El Niño conditions and cannot now predict what will happen to the birds in the coming months,” said Ralph W. Schreiber, curator of ornithology at the Natural History Museum of Los Angeles County in California. Heisthe ornithologist who discovered the disappearance. “The recovery of the bird populations depends on the food supply in the waters surrounding the island.” The island's birds feed exclusively on small fish and squid.

  2. Air Conditioning and Refrigeration Book III.

    ERIC Educational Resources Information Center

    Eckes, William; Fulkerson, Dan

    Designed to present theory as a functional aspect, this air conditioning and refrigeration curriculum guide is comprised of nine units of instruction. Unit titles include (1) Job Orientation, (2) Applying for a Job, (3) Customer Relations, (4) Business Management, (5) Psychometrics, (6) Residential Heat Loss and Heat Gain, (7) Duct Design and…

  3. The Point of No Return

    PubMed Central

    Logan, Gordon D.

    2015-01-01

    Bartlett (1958) described the point of no return as a point of irrevocable commitment to action, which was preceded by a period of gradually increasing commitment. As such, the point of no return reflects a fundamental limit on the ability to control thought and action. I review the literature on the point of no return, taking three perspectives. First, I consider the point of no return from the perspective of the controlled act, as a locus in the architecture and anatomy of the underlying processes. I review experiments from the stop-signal paradigm that suggest that the point of no return is located late in the response system. Then I consider the point of no return from the perspective of the act of control that tries to change the controlled act before it becomes irrevocable. From this perspective, the point of no return is a point in time that provides enough “lead time” for the act of control to take effect. I review experiments that measure the response time to the stop signal as the lead time required for response inhibition in the stop-signal paradigm. Finally, I consider the point of no return in hierarchically controlled tasks, in which there may be many points of no return at different levels of the hierarchy. I review experiments on skilled typing that suggest different points of no return for the commands that determine what is typed and the countermands that inhibit typing, with increasing commitment to action the lower the level in the hierarchy. I end by considering the point of no return in perception and thought as well as action. PMID:25633089

  4. Enhanced Mixing in a Rectangular Duct

    NASA Technical Reports Server (NTRS)

    Liscinsky, D. S.; True, B.

    2003-01-01

    An experimental investigation of the mixing of non-reacting opposed rows of jets injected normal to a confined rectangular crossflow has been conducted. Planar Mie-scattering was used to measure the time-average concentration distribution of the jet fluid in planes perpendicular to the duct axis. Particular emphasis was placed on the study of closely spaced orifice configurations applicable to the mixing zone of an RQL combustor. Baseline studies were performed of mixing under "ideal" conditions, i.e., plenum fed jets injecting into a crossflow uniform in velocity and turbulence intensity. In addition, more practical ("non-ideal") issues encountered during hardware design were also studied. As in other studies, mixing effectiveness, determined using a spatial unmixedness parameter based on the variance of mean jet concentration distributions, was found to be optimum when the spacing-to-duct-height ratio was inversely proportional to the square root of the jet-to-mainstream momentum-flux ratio. This relationship is suitable for design under ideal flow conditions. Inlet flow boundary conditions of the jet and approach flow (mainstream) were found to strongly influence mixing performance, but no attempt was made to determine optimum performance under non-ideal conditions. The tests performed do offer some guidance as to expected mixing behavior for several common variables likely to be imposed by hardware constraints. Additionally, in this study it was found that for rows of orifices with opposite centerlines inline, mixing was similar for blockages up to 89 percent (previous crossflow mixing studies concerned with dilution zone configurations, blockages were typically less than 50 percent). Lower levels of unmixedness were obtained as a function of downstream location when axial injection length was minimized. Mixing may be enhanced if orifice centerlines of opposed rows are staggered, but blockage must be =50 percent in this configuration. Round hole and "square

  5. 14 CFR 23.1103 - Induction system ducts.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... duct and entering any other compartment of the airplane in which a hazard would be created by the entry... system must be suitably constructed of material that will not produce hazardous quantities of toxic...

  6. 14 CFR 23.1103 - Induction system ducts.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... duct and entering any other compartment of the airplane in which a hazard would be created by the entry... system must be suitably constructed of material that will not produce hazardous quantities of toxic...

  7. Flow field measurements in a 90 degree turning duct

    NASA Technical Reports Server (NTRS)

    Crawford, Roger A.; Peters, Carroll E.

    1985-01-01

    The objective of this investigation is the experimental evaluation of the influence of inlet turbulence intensity on secondary flow development in a turning duct. The existing 25.4 cm square turning duct (90) facility is being utilized to investigate of bulk turbulence levels on secondary flow development. The large scale duct flow facility allows detailed mean velocity and turbulence quantities to be measured at several streamwise planes in the curved duct. Non-intrusive laser velocimetry is being used to measure the mean and fluctuating components of velocity in all three orthogonal directions. To assure that the turbulence measurements are unbiased by particle lag and other effects, comparison hot wire data will be taken to validate the laser velocimetry system calibration.

  8. External linkage tie permits reduction in ducting system flange thickness

    NASA Technical Reports Server (NTRS)

    Pfleger, R. O.

    1966-01-01

    External linkage tie reduces flange thickness and increases seal efficiency in high pressure ducting and piping systems. The linkage transmits the pressure separating load to the tube wall behind the flange allowing the flange to support only the seal.

  9. Measure Guideline: Buried and/or Encapsulated Ducts

    SciTech Connect

    Shapiro, C.; Zoeller, W.; Mantha, P.

    2013-08-01

    Buried and/or encapsulated ducts (BEDs) are a class of advanced, energy-efficiency strategies intended to address the significant ductwork thermal losses associated with ducts installed in unconditioned attics. BEDs are ducts installed in unconditioned attics that are covered in loose-fill insulation and/or encapsulated in closed cell polyurethane spray foam insulation. This Measure Guideline covers the technical aspects of BEDs as well as the advantages, disadvantages, and risks of BEDs compared to other alternative strategies. This guideline also provides detailed guidance on installation of BEDs strategies in new and existing homes through step-by-step installation procedures. Some of the procedures presented here, however, require specialized equipment or expertise. In addition, some alterations to duct systems may require a specialized license.

  10. Nasolacrimal Duct Mucocele: Case Report and Literature Review

    PubMed Central

    Britto, Fernanda Carneiro Corujeira de; Rosier, Vitor Veloso; Luz, Tovar Vicente; Verde, Raquel Crisóstomo Lima; Lima, Clara Mônica Figueiredo de; Lessa, Marcus Miranda

    2014-01-01

    Introduction Mucoceles are benign expansive cystic formations, composed of a mucus-secreting epithelium (respiratory or pseudostratified epithelium). Nasolacrimal mucocele occurs in a small proportion of children with nasolacrimal duct obstruction and is characterized by a cystic mass in the medial canthus with dilation of the nasolacrimal duct; although dacryocystoceles are rare in adults, they have been reported in patients with trachoma. Objective Discuss clinical aspects, diagnosis, and therapeutic management of mucocele of nasolacrimal duct based on literature review. Resumed Report The authors report a case of bilateral congenital nasolacrimal duct cysts in a 30-year-old man, identified as a tumor in the topography of both lacrimal sacs since birth without associated symptoms. The patient underwent successive surgical treatments, leading to recurrence of the tumor at the right side and recurrent local infections. Conclusion Endoscopic dacryocystorhinostomy has been increasingly used with good results and success rates similar to the external access. PMID:25992160

  11. Nasolacrimal duct mucocele: case report and literature review.

    PubMed

    Britto, Fernanda Carneiro Corujeira de; Rosier, Vitor Veloso; Luz, Tovar Vicente; Verde, Raquel Crisóstomo Lima; Lima, Clara Mônica Figueiredo de; Lessa, Marcus Miranda

    2015-01-01

    Introduction Mucoceles are benign expansive cystic formations, composed of a mucus-secreting epithelium (respiratory or pseudostratified epithelium). Nasolacrimal mucocele occurs in a small proportion of children with nasolacrimal duct obstruction and is characterized by a cystic mass in the medial canthus with dilation of the nasolacrimal duct; although dacryocystoceles are rare in adults, they have been reported in patients with trachoma. Objective Discuss clinical aspects, diagnosis, and therapeutic management of mucocele of nasolacrimal duct based on literature review. Resumed Report The authors report a case of bilateral congenital nasolacrimal duct cysts in a 30-year-old man, identified as a tumor in the topography of both lacrimal sacs since birth without associated symptoms. The patient underwent successive surgical treatments, leading to recurrence of the tumor at the right side and recurrent local infections. Conclusion Endoscopic dacryocystorhinostomy has been increasingly used with good results and success rates similar to the external access. PMID:25992160

  12. Diaphragm eliminates leakage in cryogenic fluid duct coupling

    NASA Technical Reports Server (NTRS)

    1965-01-01

    Duct coupling with nickel steel diaphragm of low thermal expansivity is leakproof when used with cryogenic fluids. The diaphragm, located between the two flanges of the coupling, reduces axial shrinkage at the coupling flanges to a minimum.

  13. Materials for outlet ducts in wet FGD systems

    SciTech Connect

    Rosenberg, H.S.; Koch, G.H.; Kistler, C.W.; Beavers, J.A.; Meadows, M.L.; Stewart, D.A.; Dene, C.E.

    1985-01-01

    It was found that the major materials problems are occurring with outlet ducts and stack linings. Outlet ducts and stacks are critical components in that failures may require complete boiler shutdown and loss of generating capacity for lengthy periods due to the lack of standby components or bypass capability. Accordingly, EPRI funded a study by Battelle on the performance of candidate materials in the outlet ducts of FGD systems at two utility plants. Because of the impact of materials failures on FGD system reliability, EPRI is currently funding a study by Battelle on the causes of these failures. This study involves site visits for field evaluations of the failures, laboratory analyses of samples collected in the field, and analysis of the data to establish the causes of the failures. Information on outlet ducts is presented in this paper.

  14. 68. Credit FM. Detail showing operators. Note cooling duct (now ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    68. Credit FM. Detail showing operators. Note cooling duct (now removed), governor (now removed), hand-operated needle valve controls (now removed). - Battle Creek Hydroelectric System, Battle Creek & Tributaries, Red Bluff, Tehama County, CA

  15. Technology Solutions Case Study: Buried and Encapsulated Ducts, Jacksonville, Florida

    SciTech Connect

    2013-11-01

    Ductwork installed in unconditioned attics can significantly increase the overall heating and cooling costs of residential buildings. In fact, estimated duct thermal losses for single-family residential buildings with ductwork installed in unconditioned attics range from 10% to 45%. In a study of three single-story houses in Florida, the Building America research team Consortium for Advanced Residential Buildings (CARB) investigated the strategy of using buried and/or encapsulated ducts (BED) to reduce duct thermal losses in existing homes. The BED strategy consists of burying ducts in loose-fill insulation and/or encapsulating them in closed cell polyurethane spray foam (ccSPF) insulation; specifically for use in humid climates.

  16. Bile Duct Diseases - Multiple Languages: MedlinePlus

    MedlinePlus

    ... Supplements Videos & Tools You Are Here: Home → Multiple Languages → All Health Topics → Bile Duct Diseases URL of this page: https://medlineplus.gov/languages/bileductdiseases.html Other topics A-Z A B ...

  17. Ducting arrangement for cooling a gas turbine structure

    DOEpatents

    Lee, Ching-Pang; Morrison, Jay A.

    2015-07-21

    A ducting arrangement (10) for a can annular gas turbine engine, including: a duct (12, 14) disposed between a combustor (16) and a first row of turbine blades and defining a hot gas path (30) therein, the duct (12, 14) having raised geometric features (54) incorporated into an outer surface (80); and a flow sleeve (72) defining a cooling flow path (84) between an inner surface (78) of the flow sleeve (72) and the duct outer surface (80). After a cooling fluid (86) traverses a relatively upstream raised geometric feature (90), the inner surface (78) of the flow sleeve (72) is effective to direct the cooling fluid (86) toward a landing (94) separating the relatively upstream raised geometric feature (90) from a relatively downstream raised geometric feature (94).

  18. 12. SANDSORTING BUILDING, THIRD FLOOR, VIBRATING SCREENS ON RIGHT, DUCT ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    12. SAND-SORTING BUILDING, THIRD FLOOR, VIBRATING SCREENS ON RIGHT, DUCT FOR DUST COLLECTION SYSTEM IN FOREGROUND, LOOKING NORTH - Mill "C" Complex, Sand-Sorting Building, South of Dee Bennet Road, near Illinois River, Ottawa, La Salle County, IL

  19. What Are the Risk Factors for Bile Duct Cancer?

    MedlinePlus

    ... the large intestine called ulcerative colitis. Bile duct stones , which are similar to, but much smaller than ... between ulcerative colitis and primary sclerosing cholangitis. Older age Older people are more likely than younger people ...

  20. Bile Duct Diseases - Multiple Languages: MedlinePlus

    MedlinePlus

    ... Supplements Videos & Tools You Are Here: Home → Multiple Languages → All Health Topics → Bile Duct Diseases URL of this page: https://www.nlm.nih.gov/medlineplus/languages/bileductdiseases.html Other topics A-Z A B ...

  1. High frequency sound attenuation in short flow ducts

    NASA Technical Reports Server (NTRS)

    Posey, J. W.

    1978-01-01

    A geometrical acoustics approach is proposed as a practical design tool for absorbent liners in such short flow ducts as may be found in turbofan engine nacelles. As an example, a detailed methodology is presented for three different types of sources in a parallel plate duct containing uniform ambient flow. A plane wave whose wavefronts are not normal to the duct walls, an arbitrarily located point source, and a spatially harmonic line source are each considered. Optimal wall admittance distributions are found, and it is shown how to estimate the insertion loss for any admittance distribution. The extension of the methodology to realistic source distributions in variable area cylindrical or annular ducts containing arbitrary flow is shown to be conceptually straightforward and computationally practical on a vector-hardware digital computer.

  2. Remote sensing of the evaporation duct using an X-band radar

    NASA Astrophysics Data System (ADS)

    Anderson, Kenneth D.

    1992-02-01

    Results from a unique analytical and measurement effort to assess low-altitude short-range radar detection capabilities in an evaporation ducting environment are presented. Although the measurement effort is ongoing, current results for unstable conditions validate propagation model predictions of reduced radar detection ranges within the radio horizon. In addition, discrepancies between measured and predicted radar data demand a close examination of both meteorological data and surface layer theory. At ranges near and beyond the horizon, radar detection capabilities crucially depend both on the surface layer refractivity profile and on the refractivity profile determined from upper-air observation. An empirical model to merge the surface layer with the mixed layer is discussed. Other discrepancies, which are thought to be caused either by inadequate surface layer modeling or by inadequate surface layer meteorological measurements, suggest the need for an improved surface layer model. Remote sensing of the evaporation duct by radar measurements is not a viable tactical tool. However, the combination of direct surface and upper-air meteorological measurements with remotely sensed radar measurements and with advanced numerical modeling capabilities does provide valuable insight for a better understanding of the atmospheric surface layer and its effects on low-altitude short-range radar detection.

  3. Non-Returning Student Survey.

    ERIC Educational Resources Information Center

    Charles County Community Coll., La Plata, MD. Dept. of Institutional Research and Assessment.

    In spring 1992, Charles County Community College (CCCC) conducted a telephone survey of non-returning fall 1991 students to determine their reasons for not returning to CCCC. In order to obtain comparison data, a questionnaire designed and administered by Prince George's Community College (PGCC) (Largo, Maryland) in 1988 was used with one minor…

  4. Capital Structure and Stock Returns

    ERIC Educational Resources Information Center

    Welch, Ivo

    2004-01-01

    U.S. corporations do not issue and repurchase debt and equity to counteract the mechanistic effects of stock returns on their debt-equity ratios. Thus over one- to five-year horizons, stock returns can explain about 40 percent of debt ratio dynamics. Although corporate net issuing activity is lively and although it can explain 60 percent of debt…

  5. Differing current and optical return stroke speeds in lightning

    NASA Astrophysics Data System (ADS)

    Liang, C.; Carlson, B.; Lehtinen, N.; Cohen, M.; Marshall, R. A.; Inan, U.

    2014-04-01

    During the return stroke in downward negative cloud-to-ground lightning, a current wave propagates upward from the ground along the lightning channel. The current wave causes rapid heating of the channel and induces intense optical radiation. The optical radiation wave propagation speed along the channel has been measured to be between 1/5 and 2/3 of the speed of light. The current wave speed is commonly assumed to be the same but cannot be directly measured. Past modeling efforts treat either the thermodynamics or electrodynamics. We present the first model that simultaneously treats the coupled current and thermodynamic physics in the return stroke channel. We utilize numerical simulations using realistic high-temperature air plasma properties that self-consistently solve Maxwell's equations coupled with equations of air plasma thermodynamics. The predicted optical radiation wave speed, rise time, and attenuation agree well with observations. The model predicts significantly higher current return stroke speed.

  6. Beam loss by collimation in a neutralizer duct

    SciTech Connect

    Hamilton, G.W.; Willmann, P.A.

    1980-04-03

    Beam fractions lost by collimation in a neutralizer duct are computed in x-x' phase space by using three examples of slab beam distributions under a broad range of duct dimensions, beam half-widths, and beam divergences. The results can be used to design compact neutralizers and to specify beam requirements. The computer code ILOST can be used under a broad range of beam conditions to compute the fraction lost by collimation.

  7. Acoustic attenuation analysis program for ducts with mean flow

    NASA Technical Reports Server (NTRS)

    Kunze, R. K., Jr.

    1972-01-01

    A computerized acoustic attenuation prediction procedure has been developed to evaluate acoustically lined ducts for various geometric and environmental parameters. The analysis procedure is based on solutions to the acoustic wave equation, assuming uniform airflow on a duct cross section, combined with appropriate mathematical lining impedance models. The impedance models included in the analysis procedure are representative of either perforated sheet or porous polyimide impregnated fiberglass facing sheet coupled with a cellular backing space. Advantages and limitations of the analysis procedure are reviewed.

  8. Acoustic propagation in partially choked converging-diverging ducts

    NASA Astrophysics Data System (ADS)

    Kelly, J. J.; Nayfeh, A. H.; Watson, L. T.

    1982-04-01

    A computer model based on the wave-envelope technique is used to study acoustic propagation in converging-diverging hard walled and lined circular ducts carrying near sonic mean flows. The influences of the liner admittance, boundary layer thickness, spinning mode number, and mean Mach number are considered. The numerical results indicate that the diverging portion of the duct can have a strong reflective effect for partially choked flows.

  9. Tubulopapillary adenoma of the common bile duct presenting with jaundice

    PubMed Central

    Yusif-zade, Kenan; Musayev, Jamal; Yeler, Maryam

    2016-01-01

    In this report, an adult patient with tubulopapillary adenoma of the common bile duct that manifested with jaundice is presented. Diagnostic challenges were analyzed. Although adenomas of the common bile duct are rare, they should be kept in mind in the differentiation of lesions of this region. It should be remembered that these lesions radiologically could mimic carcinoma and choledocholithiasis. Endoscopic resection should be considered as the primary method for treatment. Histopathology is the gold standard in diagnosis. PMID:27528819

  10. BETTER DUCT SYSTEMS FOR HOME HEATING AND COOLING.

    SciTech Connect

    ANDREWS,J.

    2001-01-01

    This is a series of six guides intended to provide a working knowledge of residential heating and cooling duct systems, an understanding of the major issues concerning efficiency, comfort, health, and safety, and practical tips on installation and repair of duct systems. These guides are intended for use by contractors, system designers, advanced technicians, and other HVAC professionals. The first two guides are also intended to be accessible to the general reader.

  11. Numerical techniques in linear duct acoustics - A status report

    NASA Technical Reports Server (NTRS)

    Baumeister, K. J.

    1980-01-01

    A review is presented covering both finite difference and finite element analysis of small amplitude (linear) sound propagation in straight and variable area ducts with flow, as might be found in a typical turbojet engine duct, muffer, or industrial ventilation system. Both 'steady' state and transient theories are discussed. Emphasis is placed on the advantages and limitations associated with the various numerical techniques. Examples of practical problems are given for which the numerical techniques have been applied.

  12. Persistent Mullerian Duct Syndrome with Transverse Testicular Ectopia

    PubMed Central

    Kumar, P. Naresh; Venugopala, Kandgal

    2015-01-01

    Persistent Mullerian duct syndrome (PMDS) is a rare form of male pseudohermaphroditism characterized by the presence of Mullerian duct structures in a normal male with 46, XY karyotype. Transverse testicular ectopia (TTE) is rare form of testicular ectopia in which two testes are located on one inguinal side. The opposite scrotum is empty. PMDS with TTE is rare. We report a case of PMDS with TTE discovered during surgery for a right inguinal hernia in a 25-year-old male. PMID:27512542

  13. Benign disease of the common bile duct.

    PubMed

    Saxena, R; Pradeep, R; Chander, J; Kumar, P; Wig, J D; Yadav, R V; Kaushik, S P

    1988-08-01

    The incidence of common bile duct (CBD) pathology in a group of patients with benign biliary disease (n = 505) was found to be 23.2 per cent. The spectrum included 111 patients (90.2 per cent) with CBD stones, 37 of whom (33.3 per cent) had no symptoms or findings pre-operatively indicating CBD involvement. Five patients had papillary stenosis, three had postoperative CBD strictures, one had a choledochal cyst and one had an external biliary fistula. Of the 100 CBDs measuring more than 10 mm in diameter, 90 harboured calculi. In the remaining 23 CBDs measuring less than 10 mm, calculi were present in 21. The presence of CBD calculi was demonstrated by intra-operative cholangiography in 49 patients. In the remaining patients (n = 74), the diagnosis of CBD pathology was made either by percutaneous transhepatic cholangiography, endoscopic retrograde cholangio-pancreatography, T-tube cholangiography or peroperative palpation. The surgical procedures performed included choledochotomy and T-tube drainage (n = 74), transduodenal sphincteroplasty (n = 27) and choledochoduodenostomy (n = 18). The overall mortality and morbidity of CBD exploration was 3.3 per cent and 24.4 per cent respectively, which was significantly greater than that for cholecystectomy alone (0.3 per cent and 8.6 per cent respectively). Transduodenal sphincteroplasty carried a much higher mortality (11 per cent) and morbidity (52 per cent) when compared with other procedures. PMID:3167536

  14. Sarcoidosis of the liver and bile ducts.

    PubMed

    Ishak, K G

    1998-05-01

    In sarcoidosis, granulomas are frequently present in multiple organs, including the liver. Typically, epithelioid granulomas (noncaseating) are scattered throughout the liver, but confluent granulomas can be present in cases with severe hepatic involvement. The characteristic inclusions in giant cells (for example, Schaumann bodies and asteroid bodies) are not seen in all cases and are not pathognomonic. The granulomas of sarcoidosis may heal without a trace, but confluent granulomas can result in extensive, irregular scarring. Occlusion of intrahepatic portal vein branches by the granulomatous inflammation probably accounts for the development of portal hypertension in some cases. A granulomatous cholangitis leading to ductopenia seems to be the underlying pathogenetic mechanism of the chronic cholestatic syndrome of sarcoidosis. Recognition of this syndrome is important in the differential diagnosis of other chronic cholestatic diseases, such as primary biliary cirrhosis or primary sclerosing cholangitis. Other rare complications of sarcoidosis are the Budd-Chiari syndrome and obstructive jaundice attributable to hepatic hilar lymphadenopathy or strictures of the bile ducts. PMID:9581591

  15. 56. Building 105, close view of ion return RF balance ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    56. Building 105, close view of ion return RF balance tube adjustment controls. - Clear Air Force Station, Ballistic Missile Early Warning System Site II, One mile west of mile marker 293.5 on Parks Highway, 5 miles southwest of Anderson, Anderson, Denali Borough, AK

  16. Improving Diffusing S-duct Performance by Secondary Flow Control

    NASA Technical Reports Server (NTRS)

    Reichert, Bruce A.; Wendt, Bruce J.

    1994-01-01

    The objective of this research was to study ways to reduce inlet flow distortion (i.e., total pressure nonuniformity) and improve total pressure recovery in a diffusing S-duct. This was accomplished by controlling the development of secondary flows within the duct through the use of tapered-fin type vortex generators. Reported are results for the bare duct and seven different configurations of vortex generators. Data presented for each configuration include surface static pressure, surface flow visualization, and exit plane total pressure and transverse velocity. The performance of each configuration was assessed by calculating total pressure recovery and inlet distortion descriptors from the data and comparing them to the values for the bare duct. The best configuration tested reduced distortion (as measured by the DC(45) and DC(90) descriptors) by more than 50 percent while improving total pressure recovery by 0.5 percent. These results should provide valuable guidance in designing vortex generator installations in ducts and for assessing the accuracy of computational fluid dynamics (CFD) methods to calculate duct flows with installed vortex generators.

  17. [Thoracic duct valves in man and albino rat].

    PubMed

    Petrenko, V M; Kruglov, S V

    2004-01-01

    The aim of this research was to determine the number, structure and position of valves along the whole length of thoracic duct in man and albino rat. The study was performed using the material obtained from 30 human corpses of men and women aged 17 to 60 years with no history of cardiovascular pathology and from 60 outbred albino rats of both sexes aged 5 to 12 months. Material was fixed in 10% neutral formalin. Anterior wall of thoracic duct was longitudinally dissected. Thoracic duct of 30 rats was stained with gallocyanin-chrome alum, in the remaining animals it was studied after its injection with blue Gerota's mass. In most cases, the valves consisted of two semilunar cusps. Thoracic duct was found to contain on the average 14.7+/-0.2 valves in man and 11.9+/-0.2 valves in rat. Most of all valves were found in the upper (anterior) 1/3 of the thoracic duct, least--in its middle part. This seems to be determined by anatomo-topographic features of the different parts of thoracic duct. PMID:15839250

  18. WAVE PROPAGATION in the HOT DUCT of VHTR

    SciTech Connect

    Richard Schultz; Jim C. P. Liou

    2013-07-01

    In VHTR, helium from the reactor vessel is conveyed to a power conversion unit through a hot duct. In a hypothesized Depressurized Conduction Cooldown event where a rupture of the hot duct occurs, pressure waves will be initiated and reverberate in the hot duct. A numerical model is developed to quantify the transients and the helium mass flux through the rupture for such events. The flow path of the helium forms a closed loop but only the hot duct is modeled in this study. The lower plum of the reactor vessel and the steam generator are treated as specified pressure and/or temperature boundary to the hot duct. The model is based on the conservation principles of mass, momentum and energy, and on the equations of state for helium. The numerical solution is based on the method of characteristics with specified time intervals with a predictor and corrector algorithm. The rupture sub-model gives reasonable results. Transients induced by ruptures with break area equaling 20%, 10%, and 5% of the duct cross-sectional area are described.

  19. Energy efficient engine: Turbine transition duct model technology report

    NASA Technical Reports Server (NTRS)

    Leach, K.; Thurlin, R.

    1982-01-01

    The Low-Pressure Turbine Transition Duct Model Technology Program was directed toward substantiating the aerodynamic definition of a turbine transition duct for the Energy Efficient Engine. This effort was successful in demonstrating an aerodynamically viable compact duct geometry and the performance benefits associated with a low camber low-pressure turbine inlet guide vane. The transition duct design for the flight propulsion system was tested and the pressure loss goal of 0.7 percent was verified. Also, strut fairing pressure distributions, as well as wall pressure coefficients, were in close agreement with analytical predictions. Duct modifications for the integrated core/low spool were also evaluated. The total pressure loss was 1.59 percent. Although the increase in exit area in this design produced higher wall loadings, reflecting a more aggressive aerodynamic design, pressure profiles showed no evidence of flow separation. Overall, the results acquired have provided pertinent design and diagnostic information for the design of a turbine transition duct for both the flight propulsion system and the integrated core/low spool.

  20. Remote sensing of evaporation ducts for Naval warfare

    NASA Astrophysics Data System (ADS)

    Geernaert, G. L.

    1989-11-01

    Areas critical to naval operations are the prediction and application of atmospheric refractivity gradients. This report describes the use of the evaporation duct over the ocean and a plan for obtaining information about the evaporation duct by space-borne sensors. There has been little research on the theory and modeling of lower atmospheric refractivity, particularly evaporation ducts over a nonhomogeneous ocean over the past five decades. Much is known about surface layer similarity theory and propagation model techniques, but little attention has been placed on the spatial variabilities in the turbulent propagation medium (such as the atmospheric surface layer) in regions of strategic Navy interest. These regions include the coastal shelf, Gulf Stream, marginal ice zone, and those places where sharp sea surface temperature fronts exist. For tomorrow's Navy, using remote sensing techniques to infer evaporative and tropospheric ducts are a requirement. Although research efforts on ducts must couple the tropospheric and surface layer components, this report summarizes the state of the art for the evaporative duct and assess the potential of new and future results on improving next generation naval warfare capabilities.