Sample records for airway exchange catheter

  1. Bronchial lumen is the safer route for an airway exchange catheter in double-lumen tube replacement: preventable complication in airway management for thoracic surgery.

    PubMed

    Wu, Hsiang-Ling; Tai, Ying-Hsuan; Wei, Ling-Fang; Cheng, Hung-Wei; Ho, Chiu-Ming

    2017-10-01

    There is no current consensus on which lumen an airway exchange catheter (AEC) should be passed through in double-lumen endotracheal tube (DLT) to exchange for a single-lumen endotracheal tube (SLT) after thoracic surgery. We report an unusual case to provide possible solution on this issue. A 71-year-old man with lung adenocarcinoma had an event of a broken exchange catheter used during a DLT replacement with a SLT, after a video-assisted thoracic surgery. The exchange catheter was impinged at the distal tracheal lumen and snapped during manipulation. All three segments of the catheter were retrieved without further airway compromises. Placement of airway tube exchanger into the tracheal lumen of double-lumen tube is a potential contributing factor of the unusual complication. We suggest an exchange catheter be inserted into the bronchial lumen in optimal depth with the adjunct of video laryngoscope, as the safe method for double-lumen tube exchange.

  2. Use of an Airway Exchange Catheter-Assisted Extubation With Continuous End-Tidal Carbon Dioxide Monitoring in a Pediatric Patient With a Known Difficult Airway: A Case Report.

    PubMed

    Yegian, Courtney C; Volz, Lana M; Galgon, Richard E

    2018-05-11

    Tracheal extubation in children with known difficult airways is associated with an increased risk of adverse events. Currently, there is no reliable measure to predict the need for emergent reintubation due to airway inadequacy. Airway exchange catheter-assisted extubation has been shown to be a useful adjunct in decreasing the risk of adverse events due to failed extubation. We report a case of using an airway exchange catheter-assisted extubation with continuous end-tidal carbon dioxide monitoring for a pediatric patient with a known difficult airway.

  3. Acromegaly and papillomatosis: difficult intubation and use of the airway exchange catheter.

    PubMed

    Hulme, G J; Blues, C M

    1999-08-01

    We describe the anaesthetic management of a patient with acromegaly scheduled for transsphenoidal resection of a pituitary tumour who was found at intubation to have coexisting laryngeal papillomatosis. Oral intubation was impossible using both direct and fibreoptic techniques. Nasal fibreoptic intubation was successful but precluded the transsphenoidal approach to surgery. A Cook Airway Exchange Catheter [Cook (UK) Ltd, Monroe House, Letchworth SG6 1LN] was used with a Negus bronchoscope to convert to oral intubation and allow completion of surgery without resort to tracheostomy.

  4. Macroscopic barotrauma caused by stiff and soft-tipped airway exchange catheters: an in vitro case series.

    PubMed

    Axe, Robert; Middleditch, Alex; Kelly, Fiona E; Batchelor, Tim J; Cook, Tim M

    2015-02-01

    Many airway management guidelines include the use of airway exchange catheters (AECs). There are reports, however, of harm from their use, from both malpositioning and in particular from the administration of oxygen via an AEC leading to barotrauma. We used an in vitro pig lung model to investigate the safety of administering oxygen at 4 different flow rates from a high-pressure source via 2 different AECs: a standard catheter and a soft-tipped catheter. Experiments were performed with the catheters positioned either above the carina or below it at the first point of resistance to advancement (hold-up). The experiments were then repeated to produce a series of 32 cases. With an AEC positioned above the carina, we did not observe macroscopic lung damage after the administration of oxygen. The administration of oxygen through an AEC positioned below the carina resulted in macroscopic barotrauma regardless of the rate of oxygen delivery. Increasing speed of oxygen flow led to faster and more extensive damage. Use of an "injector" at 2.5 or 4 bar led to instantaneous macroscopic lung damage and advancement of the AEC through the lung tissue. Our observations were the same when both types of AECs were used. Our results are consistent with reports of harm during the use of AECs and demonstrate the risk of administering oxygen through these devices when they are positioned below the carina. An indicator, ideally made on an AEC at the time of manufacture and designed to lie at the same level as the teeth, may be useful in preventing the insertion of that AEC beyond the level of the carina and improve the safety of using such devices.

  5. Catheter-Based Sensing In The Airways

    NASA Astrophysics Data System (ADS)

    Fouke, J. M.; Saunders, K. G.

    1988-04-01

    Studies attempting to define the role of the respiratory tract in heating and humidifying inspired air point to the need for sensing many variables including airway wall and airstream temperatures, humidity, and surface fluid pH and osmolarity. In order to make such measurements in vivo in human volunteers, catheter based technologies must be exploited both to assure subject safety and subject comfort. Miniturization of the electrodes or sensors becomes a top priority. This paper describes the use of thin-film microelectronic technology to fabricate a miniature, flexible sensor which can be placed directly onto the surface of the airway to measure the electrical conductance of the fluids present. From this information the osmolarity of the surface fluid was calculated. Physiologic evaluation of the device and corroboration of the calculations was performed in mongrel dogs. We also describe the successful application of current thermistor technology for the thermal mapping of the airways in humans in order to characterize the dynamic intrathoracic events that occur during breathing. The thermal probe consisted of a flexible polyvinyl tube that contained fourteen small thermistors fixed into the catheter. Data have been obtained in dozens of people, both normal subjects and asthmatic patients, under a variety of interventions. These data have substantively advanced the study of asthma, a particularly troublesome chronic obstructive pulmonary disorder.

  6. The routine use of pediatric airway exchange catheter after extubation of adult patients who have undergone maxillofacial or major neck surgery: a clinical observational study.

    PubMed

    Dosemeci, Levent; Yilmaz, Murat; Yegin, Arif; Cengiz, Melike; Ramazanoglu, Atilla

    2004-12-01

    We conducted the present study to determine the usefulness of routinely inserting a pediatric airway exchange catheter (PAEC) before tracheal extubation of adult patients who had undergone maxillofacial or major neck surgery and have risk factors for difficult reintubation. A prospective, observational and clinical study was performed in the 25-bed general intensive care unit of a university hospital. Thirty-six adult patients who underwent maxillofacial or major neck surgery and had risk factors for difficult reintubation were extubated after insertion of the PAEC. Four of 36 (11.1%) patients required emergency reintubation after 2, 4, 6 and 18 hours after tracheal extubation, respectively. Reintubation of these patients, which was thought to be nearly impossible by direct laryngoscopy, was easily achieved over the PAEC. The PAEC can be a life-saving device during reintubation of patients with risk factors for difficult reintubation such as laryngeo-pharyngeal oedema due to surgical manipulation or airway obstruction resulting from haematoma and anatomic changes. We therefore suggest the routine use of the PAEC in patients undergoing major maxillofacial or major neck surgery.

  7. Airway exchange of highly soluble gases.

    PubMed

    Hlastala, Michael P; Powell, Frank L; Anderson, Joseph C

    2013-03-01

    Highly blood soluble gases exchange with the bronchial circulation in the airways. On inhalation, air absorbs highly soluble gases from the airway mucosa and equilibrates with the blood before reaching the alveoli. Highly soluble gas partial pressure is identical throughout all alveoli. At the end of exhalation the partial pressure of a highly soluble gas decreases from the alveolar level in the terminal bronchioles to the end-exhaled partial pressure at the mouth. A mathematical model simulated the airway exchange of four gases (methyl isobutyl ketone, acetone, ethanol, and propylene glycol monomethyl ether) that have high water and blood solubility. The impact of solubility on the relative distribution of airway exchange was studied. We conclude that an increase in water solubility shifts the distribution of gas exchange toward the mouth. Of the four gases studied, ethanol had the greatest decrease in partial pressure from the alveolus to the mouth at end exhalation. Single exhalation breath tests are inappropriate for estimating alveolar levels of highly soluble gases, particularly for ethanol.

  8. Airway exchange of highly soluble gases

    PubMed Central

    Powell, Frank L.; Anderson, Joseph C.

    2013-01-01

    Highly blood soluble gases exchange with the bronchial circulation in the airways. On inhalation, air absorbs highly soluble gases from the airway mucosa and equilibrates with the blood before reaching the alveoli. Highly soluble gas partial pressure is identical throughout all alveoli. At the end of exhalation the partial pressure of a highly soluble gas decreases from the alveolar level in the terminal bronchioles to the end-exhaled partial pressure at the mouth. A mathematical model simulated the airway exchange of four gases (methyl isobutyl ketone, acetone, ethanol, and propylene glycol monomethyl ether) that have high water and blood solubility. The impact of solubility on the relative distribution of airway exchange was studied. We conclude that an increase in water solubility shifts the distribution of gas exchange toward the mouth. Of the four gases studied, ethanol had the greatest decrease in partial pressure from the alveolus to the mouth at end exhalation. Single exhalation breath tests are inappropriate for estimating alveolar levels of highly soluble gases, particularly for ethanol. PMID:23305981

  9. Monorail Piccolino catheter: a new rapid exchange/ultralow profile coronary angioplasty system.

    PubMed

    Mooney, M R; Douglas, J S; Mooney, J F; Madison, J D; Brandenburg, R O; Fernald, R; Van Tassel, R A

    1990-06-01

    The Monorail Piccolino coronary angioplasty balloon catheter (MBC) was evaluated on 118 patients at two centers. Technical success was achieved in 110 patients (93%). Time for catheter exchange and total fluoroscopy time were significantly lower for the Monorail catheter than with standard equipment (exchange time 97 vs. 170 seconds P less than .05 and fluoroscopy time 17 vs. 88 seconds P less than .001). The advantages of rapid exchange and the ability of utilize 2 Monorail balloon catheters through one 9F guiding catheter for simultaneous inflations allowed for maximal flexibility in treating patients with bifurcation lesions. The double wire approach utilizing one Monorail balloon catheter with a 7F guiding catheter was also technically successful. The Monorail Piccolino balloon catheter has unique features that allow for greater ease of operator use, rapid catheter exchange, and optimal angiographic visualization. It is felt that this catheter design provides distinct advantages over standard angioplasty equipment.

  10. Do Not Burn Your Airway Bridge: A Technique to Safely Exchange a Tracheostomy Tube for a Tracheal Tube.

    PubMed

    Patiño, Miguel Alejandro; Truong, Dam-Thuy; Truong, Angela; Cata, Juan Pablo

    2016-10-01

    Tracheostomy is one of the most ancient and commonly performed surgical procedures. When tracheostomized patients require a subsequent intervention, it is usually necessary to exchange the tracheostomy tube for a tracheal tube, which can be dangerous. These potential complications may be overlooked or underestimated by the anesthesia providers. An inability to ventilate the patient and replace the tube after removal of a fresh tracheostomy tube can escalate rapidly to a life-threatening crisis. We present a case in which an airway exchange catheter was used to safely replace a tracheostomy tube with a tracheal tube in a patient with a fresh tracheostomy.

  11. Staphylococcus-Infected Tunneled Dialysis Catheters: Is Over-the-Wire Exchange an Appropriate Management Option?

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Langer, Jessica M.; Cohen, Raphael M.; Berns, Jeffrey S.

    Purpose: Over-the-wire exchange of tunneled dialysis catheters is the standard of care per K/DOQI guidelines for treating catheter-related bacteremia. However, Gram-positive bacteremia, specifically with staphylococcus species, may compromise over-the-wire exchange due to certain biological properties. This study addressed the effectiveness of over-the-wire exchange of staphylococcus-infected tunneled dialysis catheters compared with non-staphylococcus-infected tunneled dialysis catheters. Methods: Patients who received over-the-wire exchange of their tunneled dialysis catheter due to documented or suspected bacteremia were identified from a QA database. Study patients (n = 61) had positive cultures for Staphylococcus aureus, Staphylococcus epidermidis, or coagulase-negative staphylococcus not otherwise specified. Control patients (n =more » 35) received over-the-wire exchange of their tunneled dialysis catheter due to infection with any organism besides staphylococcus. Overall catheter survival and catheter survival among staphylococcal species were assessed. Results: There was no difference in tunneled dialysis catheter survival between study and control groups (P = 0.46). Median survival time was 96 days for study catheters and 51 days for controls; survival curves were closely superimposed. There also was no difference among the three staphylococcal groups in terms of catheter survival (P = 0.31). The median time until catheter removal was 143 days for SE, 67 days for CNS, and 88 days for SA-infected catheters. Conclusions: There is no significant difference in tunneled dialysis catheter survival between over-the-wire exchange of staphylococcus-infected tunneled dialysis catheters and those infected with other organisms.« less

  12. Oral to nasal tube exchange under fibroscopic view: a new technique for nasal intubation in a predicted difficult airway.

    PubMed

    Monclus, Enric; Garcés, Antonio; Artés, David; Mabrock, Maged

    2008-07-01

    For a predicted difficult airway, oral intubation techniques are well established in pediatric anesthesia, but nasotracheal intubation remains a problem. There are many reports concerning this, but the risk of bleeding, added to the lack of cooperation make this procedure difficult and hazardous. We describe a modification of the nasal intubation technique in two stages. First an oral intubation and then exchanging the oral for a nasal tube, in the case of a 13-year-old boy affected by an advanced stage of cherubism. Oral intubation using a laryngeal mask technique has already been reported, but problems appear during the exchange procedure and even more when direct laryngoscopy is impossible. Fiberscopic control of the exchange, and the introduction of a Cook Exchange Catheter into the trachea through the oral tube before withdrawal, permits oxygenation of the patient and acts as a guide for oral tube reintroduction if required.

  13. Impact of airway gas exchange on the multiple inert gas elimination technique: theory.

    PubMed

    Anderson, Joseph C; Hlastala, Michael P

    2010-03-01

    The multiple inert gas elimination technique (MIGET) provides a method for estimating alveolar gas exchange efficiency. Six soluble inert gases are infused into a peripheral vein. Measurements of these gases in breath, arterial blood, and venous blood are interpreted using a mathematical model of alveolar gas exchange (MIGET model) that neglects airway gas exchange. A mathematical model describing airway and alveolar gas exchange predicts that two of these gases, ether and acetone, exchange primarily within the airways. To determine the effect of airway gas exchange on the MIGET, we selected two additional gases, toluene and m-dichlorobenzene, that have the same blood solubility as ether and acetone and minimize airway gas exchange via their low water solubility. The airway-alveolar gas exchange model simulated the exchange of toluene, m-dichlorobenzene, and the six MIGET gases under multiple conditions of alveolar ventilation-to-perfusion, VA/Q, heterogeneity. We increased the importance of airway gas exchange by changing bronchial blood flow, Qbr. From these simulations, we calculated the excretion and retention of the eight inert gases and divided the results into two groups: (1) the standard MIGET gases which included acetone and ether and (2) the modified MIGET gases which included toluene and m-dichlorobenzene. The MIGET mathematical model predicted distributions of ventilation and perfusion for each grouping of gases and multiple perturbations of VA/Q and Qbr. Using the modified MIGET gases, MIGET predicted a smaller dead space fraction, greater mean VA, greater log(SDVA), and more closely matched the imposed VA distribution than that using the standard MIGET gases. Perfusion distributions were relatively unaffected.

  14. Guidewire Catheter Exchange in Pediatric Oncology: Indications, Postoperative Complications, and Outcomes.

    PubMed

    Fernandez-Pineda, I; Ortega-Laureano, L; Wu, H; Wu, J; Sandoval, J A; Rao, B N; Shochat, S J; Davidoff, A M

    2016-06-01

    Maintaining long-term central venous catheters (CVCs) in children undergoing chemotherapy can be challenging. Guidewire catheter exchange (GCE) replaces a CVC without repeat venipuncture. This study evaluated the indications, success rate, and complications of GCE in a large cohort of pediatric cancer patients. Medical records of pediatric cancer patients who underwent GCE at our institution between 2003 and 2013 were retrospectively reviewed. Variables analyzed included gender, age at GCE, primary cancer diagnosis, indication for GCE, absolute neutrophil count (ANC) at GCE, vein used, success rate, and postoperative complications (<30 days after exchange). A total of 435 GCEs performed in 407 patients (230 males and 177 females) were reviewed. Median age at GCE was 8 years (range, 0.2-24). Acute lymphoblastic leukemia was the most common diagnosis (50.6%). The primary indication for GCE was the desire to have an alternative type of CVC (71%). Other indications included catheter displacement (17%), catheter malfunction (11%), and catheter infection (1%). Median ANC at GCE was 2,581/mm(3) (range, 0-43,400). Left subclavian vein was more commonly used (57.7%). The success rate of GCE was 93.4% (406 of 435 procedures, 95% confidence interval: 91.0-97.5%). A total of 33 (7.5%) postoperative complications occurred including central line associated bloodstream infection (CLABSI) (n = 20, 4.5%), catheter dislodgement (n = 6, 1.4%), and catheter malfunction (n = 7, 1.6%). We conclude that GCE in pediatric cancer patients is associated with a high success rate and a low risk of complications. The most common postoperative complication, CLABSI, occurred at a rate significantly lower than following de novo CVC placement. © 2016 Wiley Periodicals, Inc.

  15. Definitive airway management of patients presenting with a pre-hospital inserted King LT(S)-D laryngeal tube airway: a historical cohort study.

    PubMed

    Subramanian, Arun; Garcia-Marcinkiewicz, Annery G; Brown, Daniel R; Brown, Michael J; Diedrich, Daniel A

    2016-03-01

    The King LT(S)-D laryngeal tube (King LT) has gained popularity as a bridge airway for pre-hospital airway management. In this study, we retrospectively reviewed the use of the King LT and its associated airway outcomes at a single Level 1 trauma centre. The data on all adult patients presenting to the Mayo Clinic in Rochester, Minnesota with a King LT in situ from July 1, 2007 to October 10, 2012 were retrospectively evaluated. Data collected and descriptively analyzed included patient demographics, comorbidities, etiology of respiratory failure, airway complications, subsequent definitive airway management technique, duration of mechanical ventilation, and status at discharge. Forty-eight adult patients met inclusion criteria. The most common etiology for respiratory failure requiring an artificial airway was cardiac arrest [28 (58%) patients] or trauma [9 (19%) patients]. Four of the nine trauma patients had facial trauma. Surgical tracheostomy was the definitive airway management technique in 14 (29%) patients. An airway exchange catheter, direct laryngoscopy, and video laryngoscopy were used in 11 (23%), ten (21%), and ten (21%) cases, respectively. Seven (78%) of the trauma patients underwent surgical tracheostomy compared with seven (18%) of the medical patients. Adverse events associated with King LT use occurred in 13 (27%) patients, with upper airway edema (i.e., tongue engorgement and glottic edema) being most common (19%). In this study of patients presenting to a hospital with a King LT, the majority of airway exchanges required an advanced airway management technique beyond direct laryngoscopy. Upper airway edema was the most common adverse observation associated with King LT use.

  16. Respiration and heartbeat signal detection from airflow at airway in rat by catheter flow sensor with temperature compensation function

    NASA Astrophysics Data System (ADS)

    Hasegawa, Y.; Kawaoka, H.; Yamada, T.; Matsushima, M.; Kawabe, T.; Shikida, M.

    2017-12-01

    We previously proposed an evaluation method for detecting both respiration and heartbeat signals from the airflow at the mouth (Kawaoka et al 201518th Int. Conf. on Solid-State Sensors, Actuators and Microsystems; Kawaoka et al 2015 IEEE Sensors; Kawaoka et al 2016 Technical Digest IEEE Micro Electro Mechanical Systems Conf.). In the current study, we developed a catheter flow sensor with temperature compensation that uses MEMS technologies and used it to directly detect the breathing airflow in the airway of a rat. The temperature sensors were integrated with the catheter flow sensor. Heaters working as airflow and temperature sensors were produced on polymer film by using the same fabrication process so that the temperature coefficients of their resistances would coincide. As a result, the variation in sensor outputs due to the airflow temperature changes ranging from 20 °C to 34 °C was suppressed to less than 2.5%. The developed catheter flow sensor was inserted into the airway of a rat to detect both respiration and heartbeat signals. The accuracy of the breathing airflow measurements was improved thanks to the temperature compensation. The tidal volume variations between the expired and inspired air were suppressed to within 5%. Heartbeat signal information was extracted from the measured breathing waveforms by applying a discrete Fourier transform.

  17. Novel Method for Exchange of Impella Circulatory Assist Catheter: The "Trojan Horse" Technique.

    PubMed

    Phillips, Colin T; Tamez, Hector; Tu, Thomas M; Yeh, Robert W; Pinto, Duane S

    2017-07-01

    Patients with an indwelling Impella may require escalation of hemodynamic support or exchange to another circulatory assistance platform. As such, preservation of vascular access is preferable in cases where anticoagulation cannot be discontinued or to facilitate exchange to an alternative catheter or closure device. Challenges exist in avoiding bleeding and loss of wire access in these situations. We describe a single-access "Trojan Horse" technique that minimizes bleeding while maintaining arterial access for rapid exchange of this percutaneous ventricular assist device.

  18. Risk of Venous Thromboembolism Following Peripherally Inserted Central Catheter Exchange: An Analysis of 23,000 Hospitalized Patients.

    PubMed

    Chopra, Vineet; Kaatz, Scott; Grant, Paul; Swaminathan, Lakshmi; Boldenow, Tanya; Conlon, Anna; Bernstein, Steven J; Flanders, Scott A

    2018-02-01

    Catheter exchange over a guidewire is frequently performed for malfunctioning peripherally inserted central catheters (PICCs). Whether such exchanges are associated with venous thromboembolism is not known. We performed a retrospective cohort study to assess the association between PICC exchange and risk of thromboembolism. Adult hospitalized patients that received a PICC during clinical care at one of 51 hospitals participating in the Michigan Hospital Medicine Safety consortium were included. The primary outcome was hazard of symptomatic venous thromboembolism (radiographically confirmed upper-extremity deep vein thrombosis and pulmonary embolism) in those that underwent PICC exchange vs those that did not. Of 23,010 patients that underwent PICC insertion in the study, 589 patients (2.6%) experienced a PICC exchange. Almost half of all exchanges were performed for catheter dislodgement or occlusion. A total of 480 patients (2.1%) experienced PICC-associated deep vein thrombosis. The incidence of deep vein thrombosis was greater in those that underwent PICC exchange vs those that did not (3.6% vs 2.0%, P < .001). Median time to thrombosis was shorter among those that underwent exchange vs those that did not (5 vs 11 days, P = .02). Following adjustment, PICC exchange was independently associated with twofold greater risk of thrombosis (hazard ratio [HR] 1.98; 95% confidence interval [CI], 1.37-2.85) vs no exchange. The effect size of PICC exchange on thrombosis was second in magnitude to device lumens (HR 2.06; 95% CI, 1.59-2.66 and HR 2.31; 95% CI, 1.6-3.33 for double- and triple-lumen devices, respectively). Guidewire exchange of PICCs may be associated with increased risk of thrombosis. As some exchanges may be preventable, consideration of risks and benefits of exchanges in clinical practice is needed. Published by Elsevier Inc.

  19. The effect of closed system suction on airway pressures when using the Servo 300 ventilator.

    PubMed

    Frengley, R W; Closey, D N; Sleigh, J W; Torrance, J M

    2001-12-01

    To measure airway pressures during closed system suctioning with the ventilator set to three differing modes of ventilation. Closed system suctioning was conducted in 16 patients following cardiac surgery. Suctioning was performed using a 14 French catheter with a vacuum level of -500 cmH2O through an 8.0 mm internal diameter endotracheal tube. The lungs were mechanically ventilated with a Servo 300 ventilator set to one of three ventilation modes: volume-control, pressure-control or CPAP/pressure support. Airway pressures were measured via a 4 French electronic pressure transducer in both proximal and distal airways. Following insertion of the suction catheter, end-expiratory pressure increased significantly (p < 0.001) in both pressure-control and volume-control ventilation. This increase was greatest (p = 0.018) in volume-control mode (2.7 +/- 1.7 cmH2O). On performing a five second suction, airway pressure decreased in all modes, however the lowest airway pressure in volume-control mode (-4.9 +/- 4.0 cmH2O) was significantly (p = 0.001) less than the lowest airway pressure recorded in either pressure-control (0.8 +/- 1.9 cmH2O) or CPAP/pressure support (0.4 +/- 2.8 cmH2O) modes. In CPAP/pressure support mode, 13 of the 16 patients experienced a positive pressure 'breath' at the end of suctioning with airway pressures rising to 21 +/- 1.6 cmH2O. Closed system suctioning in volume control ventilation may result in elevations of end-expiratory pressure following catheter insertion and subatmospheric airway pressures during suctioning. Pressure control ventilation produces less elevation of end-expiratory pressure following catheter insertion and is less likely to be associated with subatmospheric airway pressures during suctioning. CPAP/pressure support has no effect on end-expiratory pressure following catheter insertion and subatmospheric airway pressures are largely avoided during suctioning.

  20. Exercise-induced bronchoconstriction alters airway nitric oxide exchange in a pattern distinct from spirometry.

    PubMed

    Shin, Hye-Won; Schwindt, Christina D; Aledia, Anna S; Rose-Gottron, Christine M; Larson, Jennifer K; Newcomb, Robert L; Cooper, Dan M; George, Steven C

    2006-12-01

    Exhaled nitric oxide (NO) is altered in asthmatic subjects with exercise-induced bronchoconstriction (EIB). However, the physiological interpretation of exhaled NO is limited because of its dependence on exhalation flow and the inability to distinguish completely proximal (large airway) from peripheral (small airway and alveolar) contributions. We estimated flow-independent NO exchange parameters that partition exhaled NO into proximal and peripheral contributions at baseline, postexercise challenge, and postbronchodilator administration in steroid-naive mild-intermittent asthmatic subjects with EIB (24-43 yr old, n = 9) and healthy controls (20-31 yr old, n = 9). The mean +/- SD maximum airway wall flux and airway diffusing capacity were elevated and forced expiratory flow, midexpiratory phase (FEF(25-75)), forced expiratory volume in 1 s (FEV(1)), and FEV(1)/forced vital capacity (FVC) were reduced at baseline in subjects with EIB compared with healthy controls, whereas the steady-state alveolar concentration of NO and FVC were not different. Compared with the response of healthy controls, exercise challenge significantly reduced FEV(1) (-23 +/- 15%), FEF(25-75) (-37 +/- 18%), FVC (-12 +/- 12%), FEV(1)/FVC (-13 +/- 8%), and maximum airway wall flux (-35 +/- 11%) relative to baseline in subjects with EIB, whereas bronchodilator administration only increased FEV(1) (+20 +/- 21%), FEF(25-75) (+56 +/- 41%), and FEV(1)/FVC (+13 +/- 9%). We conclude that mild-intermittent steroid-naive asthmatic subjects with EIB have altered airway NO exchange dynamics at baseline and after exercise challenge but that these changes occur by distinct mechanisms and are not correlated with alterations in spirometry.

  1. Achieving an adequate minute volume through a 2 mm transtracheal catheter in simulated upper airway obstruction using a modified industrial ejector.

    PubMed

    Hamaekers, A E W; Götz, T; Borg, P A J; Enk, D

    2010-03-01

    Needle cricothyrotomy and subsequent transtracheal jet ventilation (TTJV) is one of the last options to restore oxygenation while managing an airway emergency. However, in cases of complete upper airway obstruction, conventional TTJV is ineffective and dangerous. We transformed a small, industrial ejector into a simple, manual ventilator providing expiratory ventilation assistance (EVA). An ejector pump was modified to allow both insufflation of oxygen and jet-assisted expiration through an attached 75 mm long transtracheal catheter (TTC) with an inner diameter (ID) of 2 mm by alternately occluding and releasing the gas outlet of the ejector pump. In a lung simulator, the modified ejector pump was tested at different compliances and resistances. Inspiration and expiration times were measured and achievable minute volumes (MVs) were calculated to determine the effect of EVA. The modified ejector pump shortened the expiration time and an MV up to 6.6 litre min(-1) could be achieved through a 2 mm ID TTC in a simulated obstructed airway. The principle of ejector-based EVA seems promising and deserves further evaluation.

  2. Fiberoptic Intubation Using LMA™ as A Conduit and Cook® Airway Catheter as An Exchanger in A Case of Tessier 7 Facial Cleft Syndrome

    PubMed Central

    Dasgupta, D; Jain, Anand; Baxi, Vaibhavi; Parab, A; Budhakar, A

    2009-01-01

    Summary Any anaesthesiologist handling a paediatric airway must have a detailed understanding of the differences in airway anatomy, signs and symptoms of airway compromise and common paediatric airway abnormalities. In addition to various equipments needed to manage a difficult airway, there should be a clear plan for evaluation, preparation and management of life threatening complications. We share our experience of successfully managing a difficult airway of a 5 year old child with Tessier 7 facial cleft syndrome. We emphasize the importance of preoperative evaluation, preparation and use of various airway adjuncts. PMID:20640130

  3. A newly developed tool for intra-tracheal temperature and humidity assessment in laryngectomized individuals: the Airway Climate Explorer (ACE)

    PubMed Central

    Zuur, J. K.; Muller, S. H.; de Jongh, F. H. C.; van der Horst, M. J.; Shehata, M.; van Leeuwen, J.; Sinaasappel, M.

    2007-01-01

    The aim of this study is to develop a postlaryngectomy airway climate explorer (ACE) for assessment of intratracheal temperature and humidity and of influence of heat and moisture exchangers (HMEs). Engineering goals were within-device condensation prevention and fast response time characteristics. The ACE consists of a small diameter, heated air-sampling catheter connected to a heated sensor house, containing a humidity sensor. Air is sucked through the catheter by a controlled-flow pump. Validation was performed in a climate chamber using a calibrated reference sensor and in a two-flow system. Additionally, the analyser was tested in vivo. Over the clinically relevant range of humidity values (5–42 mg H2O/l air) the sensor output highly correlates with the reference sensor readings (R2 > 0.99). The 1–1/e response times are all <0.5 s. A first in vivo pilot measurement was successful. The newly developed, verified, fast-responding ACE is suitable for postlaryngectomy airway climate assessment. PMID:17629761

  4. A comparison of the I-gel supraglottic airway as a conduit for tracheal intubation with the intubating laryngeal mask airway: a manikin study.

    PubMed

    Michalek, P; Donaldson, W; Graham, C; Hinds, J D

    2010-01-01

    Insertion of a supraglottic airway and tracheal intubation through it may be indicated in resuscitation scenarios where conventional laryngoscopy fails. Various supraglottic devices have been used as conduits for tracheal intubation, including the intubating laryngeal mask airway (ILMA), the Ctrach laryngeal mask and the I-gel supraglottic airway. A prospective study with 25 participants evaluated the success rate of blind intubation (using a gum-elastic bougie, an Aintree intubating catheter (AIC) and designated tracheal tube) and fibrescope-guided tracheal intubation (through the intubating laryngeal mask airway and the I-gel supraglottic airway) on three different airway manikins. Twenty-five anaesthetists performed three intubations with each method on each of three manikins. The success rate of the fibrescope-guided technique was significantly higher than blind attempts (P<0.0001) with both devices. For fibreoptic techniques, there was no difference found between the ILMA and I-gel (P>0.05). All blind techniques were significantly more successful in the ILMA group compared to the I-gel (P<0.0001 for bougie, Aintree catheter and tracheal tube, respectively). The results of this study show that, in manikins, fibreoptic intubation through both ILMA and I-gel is a highly successful technique. Blind intubation through the I-gel showed a low success rate and should not be attempted. Copyright 2009 Elsevier Ireland Ltd. All rights reserved.

  5. Rescue ventilation: resolving a "cannot mask ventilate, cannot intubate" situation during exchange of a Combitube for a definitive airway.

    PubMed

    Rich, James M; Mason, Andrew M; Tillmann, H A; Foreman, Michael

    2009-10-01

    Our anesthesia care team was called to care for a patient who was admitted to the emergency department with the esophageal-tracheal double-lumen airway device (Combitube, Tyco Healthcare, Nellcor, Pleasanton, California) in place, which needed to be exchanged for a definitive airway because the patient required an extended period of mechanical ventilation. Several techniques were attempted to exchange the esophageal-tracheal Combitube (ETC) without success. First, we attempted direct laryngoscopy with the ETC in place after deflation of the No. 1 proximal cuff and sweeping the ETC to the left. We were prepared to use bougie-assisted intubation but could not identify any airway anatomy. After removal of the ETC, we unsuccessfully attempted ventilation/intubation with a laryngeal mask airway (LMA Fastrach, LMA North America, San Diego, California). Our third attempt was insertion of another laryngeal mask airway (LMA Unique, LMA North America) with marginal ventilation, but we again experienced unsuccessful intubation using a fiberscope. The ETC was reinserted after each intubation attempt because mask ventilation was impossible. Before proceeding with cricothyrotomy, we repeated direct laryngoscopy but without the ETC in place. We identified the tip of the epiglottis, which allowed for bougie-assisted intubation. This obviated the need for emergency cricothyrotomy.

  6. Airway-parenchymal interdependence

    PubMed Central

    Paré, Peter D; Mitzner, Wayne

    2015-01-01

    In this manuscript we discuss the interaction of the lung parenchyma and the airways as well as the physiological and pathophysiological significance of this interaction. These two components of the respiratory organ can be thought of as two independent elastic structures but in fact the mechanical properties of one influence the behavior of the other. Traditionally the interaction has focused on the effects of the lung on the airways but there is good evidence that the opposite is also true, i.e., that the mechanical properties of the airways influence the elastic properties of the parenchyma. The interplay between components of the respiratory system including the airways, parenchyma and vasculature is often referred to as “interdependence.” This interdependence transmits the elastic recoil of the lung to create an effective pressure that dilates the airways as transpulmonary pressure and lung volume increase. By using a continuum mechanics analysis of the lung parenchyma, it is possible to predict the effective pressure between the airways and parenchyma, and these predictions can be empirically evaluated. Normal airway caliber is maintained by this pressure in the adventitial interstitium of the airway, and it counteracts airway compression during forced expiration as well as the ability of airway smooth muscle to narrow airways. Interdependence has physiological and pathophysiological significance. Weakening of the forces of interdependence contributes to airway dysfunction and gas exchange impairment in acute and chronic airway diseases including asthma and emphysema. PMID:23723029

  7. The effect of heat-moisture exchanger and closed-circuit technique on airway climate during desflurane anesthesia.

    PubMed

    Lu, Chih-Cherng; Ho, Shung-Tai; Liaw, Wen-Jinn; Chen, Ruei-Ming; Chen, Ta-Liang; Lin, Chung-Yuan

    2008-01-01

    We assessed whether closed-circuit anesthesia (CCA) could provide a more favorable airway climate than semi-closed anesthesia (SCA), and we also determined the beneficial effect of heat moisture exchangers (HMEs) on the preservation of airway climate during desflurane anesthesia. Forty patients scheduled for colorectal surgery (n = 10 for each group) were randomized to receive a fresh gas flow of 250 or 3000 ml.min(-1) with or without HMEs. Anesthesia was maintained by adjusting the inspired concentration of 6% desflurane. Absolute moisture and temperature of inspired gases were measured as the baseline value first at 5 min after tracheal intubation, and then at 10, 20, 45, 60, 90, and 120 min after the induction of anesthesia. At 120 min, the inspiratory humidity and temperature were higher in CCA than in SCA. The HME led to major improvements of the humidity (from 22.1 to 35.7 mg H(2)O.l(-1)) and temperature (from 23.6 degrees C to 31.5 degrees C) of anesthetic gases in the CCA group. CCA was much more advantageous than SCA for maintaining the patient's airway climate during the 2-h study. The beneficial effect of HME on the airway climate should be emphasized, especially in patients undergoing general anesthesia.

  8. Using optical coherence tomography to detect bacterial biofilms on foley catheters (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Heidari, Andrew E.; Oh, Kyungjin; Chen, Zhongping

    2017-02-01

    Urinary tract infections(UTI) pose a serious problem for hospital patients accounting for 33% of all hospital acquired(nosocomial) infections with indwelling foley catheters. The presence of an indwelling foley catheter provides a scaffolding for circulating planktonic bacteria to adhere to and to form microbial biofilm communities that would typically be hindered by the body's innate immune system response. It is these biofilm communities that form on the inner lumen of foley catheters that provide a reservoir of pathogenic bacteria that could dislodge or disperse from the biofilm and infect urethra or bladder mucosal tissue in the urinary tract. Current diagnostic techniques of urine microbiological cultures are lacking in differentiating asymptomatic bacteriuria and symptomatic catheter-associated urinary tract infection(CAUTI) since almost all patients with chronic indwelling catheters are almost universally bacteriuruic. There is an unmet need of a diagnostic tool to assess the difference between the pathogenesis of asymptomatic bacteriuria and CAUTI, specifically at the site of the native biofilm formation. Optical Coherence Tomography(OCT) is an emerging high resolution, minimally invasive tomographic imaging technique that has shown promise in imaging biofilm structures previously in an endoscopic setting of the airway in-vivo and in microfluidic chambers. OCT can be adapted to image various sized biological surfaces and orifices such as airway branches and blood vessels by using a variety of minature endoscopic probes. In this work OCT will be used to image biofilm structure in-vitro on the inner lumen of extravasated critical care patient's foley catheters. Scanning electron microscopy will be conducted post OCT to confirm the presence of bacterial biofilm in OCT images.

  9. The simultaneous use of a heat and moisture exchanger and a heated humidifier causes critical airway occlusion in less than 24 hours.

    PubMed

    Doyle, Alexander; Mariyaselvam, Maryanne; Wijewardena, Gayathri; English, Natalie; Gent, Emma; Young, Peter

    2015-08-01

    Heat and moisture exchangers (HMEs) and heated humidifiers (HHs) may be used together inadvertently. Such an incident occurred at our institution resulting in airway occlusion. A bench-top study was conducted to compare the incidence of airway occlusion when using (1) no airway humidification, (2) HME alone, (3) HH alone, and (4) both HME and HH in combination as part of a standard breathing circuit. The simultaneous use of a HME and a HH was associated with a reduction in tidal volume (no airway humidification, P ≤ .05; HME alone, P ≤ .01; and HH alone, P ≤ .01) and an increased incidence of airway occlusion (no airway humidification, 0/7; HME alone, 0/7; HH alone, 0/7; and HME and HH in combination, 7/7; P < .0001). The use of a HME and a HH in combination is likely to result in airway occlusion. Precautions should be taken to ensure that both systems are not used together in clinical practice. Copyright © 2015 Elsevier Inc. All rights reserved.

  10. The catheter hub disinfection cap as esophageal foreign body.

    PubMed

    Tawfik, Kareem O; Myer, Charles M; Shikary, Tasneem; Goldschneider, Kenneth R

    2015-12-01

    Disinfection caps are increasingly being used to prevent catheter-associated bloodstream infections. These devices, designed for continuous passive disinfection of catheter hubs, are typically small and often brightly colored. As such, they have the potential to become pediatric airway and esophageal foreign bodies. We report two patients who developed esophageal foreign body following ingestion of disinfection caps. Given the increasing use of these devices, it is imperative that health care providers be aware of this potential iatrogenic problem. We propose that the use of disinfection caps may not be appropriate in pediatric patients with risk factors for foreign body ingestion. © 2015 The American Laryngological, Rhinological and Otological Society, Inc.

  11. Transnasal Humidified Rapid-Insufflation Ventilatory Exchange (THRIVE): a physiological method of increasing apnoea time in patients with difficult airways.

    PubMed

    Patel, A; Nouraei, S A R

    2015-03-01

    Emergency and difficult tracheal intubations are hazardous undertakings where successive laryngoscopy-hypoxaemia-re-oxygenation cycles can escalate to airway loss and the 'can't intubate, can't ventilate' scenario. Between 2013 and 2014, we extended the apnoea times of 25 patients with difficult airways who were undergoing general anaesthesia for hypopharyngeal or laryngotracheal surgery. This was achieved through continuous delivery of transnasal high-flow humidified oxygen, initially to provide pre-oxygenation, and continuing as post-oxygenation during intravenous induction of anaesthesia and neuromuscular blockade until a definitive airway was secured. Apnoea time commenced at administration of neuromuscular blockade and ended with commencement of jet ventilation, positive-pressure ventilation or recommencement of spontaneous ventilation. During this time, upper airway patency was maintained with jaw-thrust. Transnasal Humidified Rapid-Insufflation Ventilatory Exchange (THRIVE) was used in 15 males and 10 females. Mean (SD [range]) age at treatment was 49 (15 [25-81]) years. The median (IQR [range]) Mallampati grade was 3 (2-3 [2-4]) and direct laryngoscopy grade was 3 (3-3 [2-4]). There were 12 obese patients and nine patients were stridulous. The median (IQR [range]) apnoea time was 14 (9-19 [5-65]) min. No patient experienced arterial desaturation < 90%. Mean (SD [range]) post-apnoea end-tidal (and in four patients, arterial) carbon dioxide level was 7.8 (2.4 [4.9-15.3]) kPa. The rate of increase in end-tidal carbon dioxide was 0.15 kPa.min(-1) . We conclude that THRIVE combines the benefits of 'classical' apnoeic oxygenation with continuous positive airway pressure and gaseous exchange through flow-dependent deadspace flushing. It has the potential to transform the practice of anaesthesia by changing the nature of securing a definitive airway in emergency and difficult intubations from a pressured stop-start process to a smooth and unhurried undertaking

  12. [Use of the air-Q laryngeal airway and tube exchanger in a case of difficult tracheal extubation after maxillectomy].

    PubMed

    Komasawa, Nobuyasu; Ueki, Ryusuke; Iwasaki, Yohei; Tatara, Tsuneo; Tashiro, Chikara; Kaminoh, Yoshiroh

    2012-10-01

    A 79-year-old man was diagnosed with maxillary cancer and underwent total maxillectomy under general anesthesia. The oropharyngeal airway was needed for efficient mask ventilation during anesthesia induction. The maxilla was totally resected and reconstructed with skin from a femoral flap. Tracheal extubation was considered to be difficult given that mask ventilation was contraindicated due to reconstruction of the maxilla. After inserting a tube exchanger (TE) into the trachea, the tracheal tube was exchanged with an air-Q laryngeal airway through the TE. After confirming effective ventilation with the air-Q mask, the patient was awakened from anesthesia. We confirmed sufficient spontaneous breathing and no active bleeding in the pharynx. After re-inserting the TE thorough air-Q, the air-Q was removed, followed by removal of the TE. These findings suggest that the air-Q and TE were effective in a case of difficult extubation after maxillectomy.

  13. Multi-modal anatomical optical coherence tomography and CT for in vivo dynamic upper airway imaging

    NASA Astrophysics Data System (ADS)

    Balakrishnan, Santosh; Bu, Ruofei; Price, Hillel; Zdanski, Carlton; Oldenburg, Amy L.

    2017-02-01

    We describe a novel, multi-modal imaging protocol for validating quantitative dynamic airway imaging performed using anatomical Optical Coherence Tomography (aOCT). The aOCT system consists of a catheter-based aOCT probe that is deployed via a bronchoscope, while a programmable ventilator is used to control airway pressure. This setup is employed on the bed of a Siemens Biograph CT system capable of performing respiratory-gated acquisitions. In this arrangement the position of the aOCT catheter may be visualized with CT to aid in co-registration. Utilizing this setup we investigate multiple respiratory pressure parameters with aOCT, and respiratory-gated CT, on both ex vivo porcine trachea and live, anesthetized pigs. This acquisition protocol has enabled real-time measurement of airway deformation with simultaneous measurement of pressure under physiologically relevant static and dynamic conditions- inspiratory peak or peak positive airway pressures of 10-40 cm H2O, and 20-30 breaths per minute for dynamic studies. We subsequently compare the airway cross sectional areas (CSA) obtained from aOCT and CT, including the change in CSA at different stages of the breathing cycle for dynamic studies, and the CSA at different peak positive airway pressures for static studies. This approach has allowed us to improve our acquisition methodology and to validate aOCT measurements of the dynamic airway for the first time. We believe that this protocol will prove invaluable for aOCT system development and greatly facilitate translation of OCT systems for airway imaging into the clinical setting.

  14. Percutaneous dilational tracheotomy for airway management in a newborn with Pierre-Robin syndrome and a glossopharyngeal web.

    PubMed

    Pirat, Arash; Candan, Selim; Unlükaplan, Aytekin; Kömürcü, Ozgür; Kuşlu, Selim; Arslan, Gülnaz

    2012-04-01

    Pierre-Robin syndrome (PRS) is often associated with difficulty in endotracheal intubation. We present the use of percutaneous dilational tracheotomy (PDT) for airway management of a newborn with PRS and a glossopharyngeal web. A 2-day-old term newborn with PRS and severe obstructive dyspnea was evaluated by the anesthesiology team for airway management. A direct laryngoscopy revealed a glossopharyngeal web extending from the base of the tongue to the posterior pharyngeal wall. The infant was spontaneously breathing through a 2 mm diameter fistula in the center of this web. It was decided that endotracheal intubation was impossible, and a PDT was planned. The trachea of the newborn was cannulated, using a 20 gauge peripheral venous catheter and a 0.71 mm guide wire was introduced through this catheter. Using 5 French, 7 French, 9 French, and 11 French central venous catheter kit dilators, staged tracheotomy stoma dilation was performed. By inserting a size 3.0 tracheotomy cannula, PDT was successfully completed in this newborn. This case describes the successful use of PDT for emergency airway management of a newborn with PRS and glossopharyngeal web.

  15. Steam-deformed Judkins-left guiding catheter with use of the GuideLiner® catheter to deliver stents for anomalous right coronary artery

    PubMed Central

    Kuno, Toshiki; Fujisawa, Taishi; Yamazaki, Hiroyuki; Motoda, Hiroyuki; Kodaira, Masaki; Numasawa, Yohei

    2015-01-01

    Objective: Percutaneous coronary intervention for anomalous right coronary artery (RCA) originating from the left coronary cusp is challenging because of our current inability to coaxially engage the guiding catheter. Methods: We report a case of an 88-year-old woman with non-ST segment elevation myocardial infarction, with an anomalous RCA origin. Using either the Judkins-Left catheter or Amplatz-Left catheter was difficult because of RCA ostium tortuosity. Thus, we used steam to deform the Judkins-Left catheter, but back-up support was insufficient to deliver the stent. Results: We used GuideLiner®, a novel pediatric catheter with rapid exchange/monorail systems, to enhance back-up support. Conclusions: We were able to successfully stent with both the deformed Judkins-Left guiding catheter and GuideLiner® for an anomalous RCA origin. PMID:27489700

  16. Steam-deformed Judkins-left guiding catheter with use of the GuideLiner(®) catheter to deliver stents for anomalous right coronary artery.

    PubMed

    Kuno, Toshiki; Fujisawa, Taishi; Yamazaki, Hiroyuki; Motoda, Hiroyuki; Kodaira, Masaki; Numasawa, Yohei

    2015-01-01

    Percutaneous coronary intervention for anomalous right coronary artery (RCA) originating from the left coronary cusp is challenging because of our current inability to coaxially engage the guiding catheter. We report a case of an 88-year-old woman with non-ST segment elevation myocardial infarction, with an anomalous RCA origin. Using either the Judkins-Left catheter or Amplatz-Left catheter was difficult because of RCA ostium tortuosity. Thus, we used steam to deform the Judkins-Left catheter, but back-up support was insufficient to deliver the stent. We used GuideLiner®, a novel pediatric catheter with rapid exchange/monorail systems, to enhance back-up support. We were able to successfully stent with both the deformed Judkins-Left guiding catheter and GuideLiner® for an anomalous RCA origin.

  17. Awake Craniotomy: A New Airway Approach.

    PubMed

    Sivasankar, Chitra; Schlichter, Rolf A; Baranov, Dimitry; Kofke, W Andrew

    2016-02-01

    Awake craniotomies have been performed regularly at the University of Pennsylvania since 2004. Varying approaches to airway management are described for this procedure, including intubation with an endotracheal tube and use of a laryngeal mask airway, simple facemask, or nasal cannula. In this case series, we describe the successful use (i.e., no need for endotracheal intubation related to inadequate gas exchange) of bilateral nasopharyngeal airways in 90 patients undergoing awake craniotomies. The use of nasopharyngeal airways can ease the transition between the asleep and awake phases of the craniotomy without the need to stimulate the airway. Our purpose was to describe our experience and report adverse events related to this technique.

  18. Effect of impeller design and spacing on gas exchange in a percutaneous respiratory assist catheter.

    PubMed

    Jeffries, R Garrett; Frankowski, Brian J; Burgreen, Greg W; Federspiel, William J

    2014-12-01

    Providing partial respiratory assistance by removing carbon dioxide (CO2 ) can improve clinical outcomes in patients suffering from acute exacerbations of chronic obstructive pulmonary disease and acute respiratory distress syndrome. An intravenous respiratory assist device with a small (25 Fr) insertion diameter eliminates the complexity and potential complications associated with external blood circuitry and can be inserted by nonspecialized surgeons. The impeller percutaneous respiratory assist catheter (IPRAC) is a highly efficient CO2 removal device for percutaneous insertion to the vena cava via the right jugular or right femoral vein that utilizes an array of impellers rotating within a hollow-fiber membrane bundle to enhance gas exchange. The objective of this study was to evaluate the effects of new impeller designs and impeller spacing on gas exchange in the IPRAC using computational fluid dynamics (CFD) and in vitro deionized water gas exchange testing. A CFD gas exchange and flow model was developed to guide a progressive impeller design process. Six impeller blade geometries were designed and tested in vitro in an IPRAC device with 2- or 10-mm axial spacing and varying numbers of blades (2-5). The maximum CO2 removal efficiency (exchange per unit surface area) achieved was 573 ± 8 mL/min/m(2) (40.1 mL/min absolute). The gas exchange rate was found to be largely independent of blade design and number of blades for the impellers tested but increased significantly (5-10%) with reduced axial spacing allowing for additional shaft impellers (23 vs. 14). CFD gas exchange predictions were within 2-13% of experimental values and accurately predicted the relative improvement with impellers at 2- versus 10-mm axial spacing. The ability of CFD simulation to accurately forecast the effects of influential design parameters suggests it can be used to identify impeller traits that profoundly affect facilitated gas exchange. Copyright © 2014 International Center for

  19. Patency of paediatric endotracheal tubes for airway instrumentation.

    PubMed

    Elfgen, J; Buehler, P K; Thomas, J; Kemper, M; Imach, S; Weiss, M

    2017-01-01

    Airway exchange catheters (AEC) and fiberoptic bronchoscopes (FOB) for tracheal intubation are selected so that there is only a minimal gap between their outer and inner diameter of endotracheal tube (ETT) to minimize the risk of impingement during airway instrumentation. This study aimed to test the ease of passage of FOBs and AECs through paediatric ETT of different sizes and from different manufacturers when using current recommendations for dimensional equipment compatibility taken from text books and manufacturers information. Twelve different brands of cuffed and uncuffed ETT sized ID 2.5 to 5.0 mm were evaluated in an in vitro set-up. Ease of device passage as well as the locations of an impaired passage within the ETT were assessed. Redundant samples were used for same sized ETT and all measurements were triple-checked in randomized order. In total, 51 paired samples of uncuffed as well as cuffed paediatric ETT were tested. There were substantial differences in the ease of ETT passage concordantly for FOBs and AECs among different manufacturers, but also among the product lines from the same manufacturer for a given ID size. Restriction to passage most frequently was found near the endotracheal tube tip or as a gradually increasing resistance along the ETT shaft. Current recommendations for dimensional equipment compatibility AECs and FOBs with ETTs do not appear to be completely accurate for all ETT brands available. We recommend that specific equipment combinations always must be tested carefully together before attempting to use them in a patient. © 2016 The Acta Anaesthesiologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  20. The Development for Polymer Actuator Active Catheter System

    PubMed Central

    Sewa, S.; Onishi, K.; Oguro, K.; Asaka, K.; Taki, W.; Toma, N.

    2001-01-01

    Summary Electric stimuli polymer-metal composite actuator material has been developed for active catheter system and other widely new applications. The polymer actuator is made of ion exchange polymer and gold as electrode, and a pulse voltage of 3 volts on the actuator gave a quick bend 90 degree angle. This composite material is possible to make small size, light and soft actuator. So now we can actually develop an active catheter for the interventional radiology surgery. The prototype polymer actuator active catheter has been developed by using polymer actuator technology and Micro Electronics Mechanical System (MEMS) technologies. The active catheter is controllable from the outside of the body by electric signal. The tip part of the catheter is made of the polymer actuator tube and bends 90 degree angles. The animal tests (dog) showed good actuator performance to control right direction and bending angle at bifurcation of blood vessel and aneurysms. PMID:20663388

  1. A role for Na+/H+ exchange in contraction of guinea pig airways by endothelin-1 in vitro.

    PubMed

    Battistini, B; Filep, J G; Cragoe, E J; Fournier, A; Sirois, P

    1991-03-15

    Endothelin-1-induced contractions of guinea pig tracheal and bronchial strips were dose-dependently attenuated by the amiloride analogues 5-(N-ethyl-N-isopropyl)amiloride (EIPA, 1-10 microM) and 5-(N,N-hexamethylene)amiloride (HMA, 1-10 microM). The calculated Ki values for EIPA and HMA were 0.11 +/- 0.02 microM and 0.06 +/- 0.02 microM in the trachea, and 0.28 +/- 0.11 microM and 0.70 +/- 0.25 microM in the bronchus, respectively. These values are in the same order of magnitude as those reported for inhibition of the Na+/H+ exchange in cells. Amiloride (1-10 microM) was ineffective. These data suggest that activation of the Na+/H+ exchange by ET-1 may be involved in mediating its myotropic action in guinea pig airway smooth muscle.

  2. Clinical experience with the Monorail balloon catheter for coronary angioplasty.

    PubMed

    Finci, L; Meier, B; Roy, P; Steffenino, G; Rutishauser, W

    1988-01-01

    The Monorail balloon catheter is distinctly different from other current balloon catheters: the guidewire passes through the balloon itself, exits the catheter proximal to the balloon, and runs alongside its small shaft (3 French) through the guiding catheter. Monorail coronary angioplasty was attempted in 61 patients on 73 lesions with balloons from 2.0 to 3.7 mm. Angiographic success was obtained in 66 lesions (90%). For 15 lesions, balloon exchanges were needed. In three lesions, the Monorail balloon failed to cross the lesion, while a standard balloon succeeded; two lesions could not be crossed with any balloon. Vessel occlusion occurred in four patients: two had emergency surgery without infarct (one died suddenly 4 days later and one had a stroke 1 day later), one was recanalized with a standard balloon, and one had a myocardial infarct. Continuous infusion of urokinase was used until patient 3 in whom problems with the delivery system led to cardiocerebral air embolization (with complete recovery). No thrombotic complications were observed in the subsequent 58 patients with only a bolus of 10,000 U of heparin. The Monorail balloon facilitates contrast injections and balloon exchanges but appears more difficult to pass through tight lesions. Omission of the previously recommended infusion with a thrombolytic agent proved safe.

  3. Ventilation through a small-bore catheter: optimizing expiratory ventilation assistance.

    PubMed

    Hamaekers, A E W; Borg, P A J; Götz, T; Enk, D

    2011-03-01

    Emergency ventilation through a small-bore transtracheal catheter can be lifesaving in a 'cannot intubate, cannot ventilate' situation. Ejectors, capable of creating suction by the Bernoulli principle, have been proposed to facilitate expiration through small-bore catheters. In this bench study, we compared a novel, purpose-built ventilation ejector (DE 5) with a previously proposed, modified industrial ejector (SBP 07). The generated insufflation pressures, suction pressures in static and dynamic situations, and also suction capacities and entrainment ratios of the SBP 07 and the DE 5 were determined. The DE 5 was also tested in a lung simulator with a simulated complete upper airway obstruction. Inspiratory and expiratory times through a transtracheal catheter were measured at various flow rates and achievable minute volumes were calculated. In a static situation, the SBP 07 showed a more negative pressure build-up compared with the DE 5. However, in a dynamic situation, the DE 5 generated a more negative pressure, resulting in a higher suction capacity. Employment of the DE 5 at a flow rate of 18 litre min(-1) allowed a minute volume through the transtracheal catheter of up to 8.27 litre min(-1) at a compliance of 100 ml cm H(2)O(-1). The efficiency of the DE 5 depended on the flow rate of the driving gas and the compliance of the lung simulator. In laboratory tests, the DE 5 is an optimized ventilation ejector suitable for applying expiratory ventilation assistance. Further research may confirm the clinical applicability as a portable emergency ventilator for use with small-bore catheters.

  4. Lung volume changes during cleaning of closed endotracheal suction catheters: a randomized crossover study using electrical impedance tomography.

    PubMed

    Corley, Amanda; Sharpe, Nicola; Caruana, Lawrence R; Spooner, Amy J; Fraser, John F

    2014-04-01

    Airway suctioning in mechanically ventilated patients is required to maintain airway patency. Closed suction catheters (CSCs) minimize lung volume loss during suctioning but require cleaning post-suction. Despite their widespread use, there is no published evidence examining lung volumes during CSC cleaning. The study objectives were to quantify lung volume changes during CSC cleaning and to determine whether these changes were preventable using a CSC with a valve in situ between the airway and catheter cleaning chamber. This prospective randomized crossover study was conducted in a metropolitan tertiary ICU. Ten patients mechanically ventilated via volume-controlled synchronized intermittent mandatory ventilation (SIMV-VC) and requiring manual hyperinflation (MHI) were included in this study. CSC cleaning was performed using 2 different brands of CSC (one with a valve [Ballard Trach Care 72, Kimberly-Clark, Roswell, Georgia] and one without [Portex Steri-Cath DL, Smiths Medical, Dublin, Ohio]). The maneuvers were performed during both SIMV-VC and MHI. Lung volume change was measured via impedance change using electrical impedance tomography. A mixed model was used to compare the estimated means. During cleaning of the valveless CSC, significant decreases in lung impedance occurred during MHI (-2563 impedance units, 95% CI 2213-2913, P < .001), and significant increases in lung impedance occurred during SIMV (762 impedance units, 95% CI 452-1072, P < .001). In contrast, cleaning of the CSC with a valve in situ resulted in non-significant lung volume changes and maintenance of normal ventilation during MHI and SIMV-VC, respectively (188 impedance units, 95% CI -136 to 511, P = .22; and 22 impedance units, 95% CI -342 to 299, P = .89). When there is no valve between the airway and suction catheter, cleaning of the CSC results in significant derangements in lung volume. Therefore, the presence of such a valve should be considered essential in preserving lung volumes

  5. Airway bypass treatment of severe homogeneous emphysema: taking advantage of collateral ventilation.

    PubMed

    Choong, Cliff K; Cardoso, Paulo F G; Sybrecht, Gerhard W; Cooper, Joel D

    2009-05-01

    Airway bypass is being investigated as a new form of minimally invasive therapy for the treatment of homogeneous emphysema. It is a bronchoscopic catheter-based procedure that creates transbronchial extra-anatomic passages at the bronchial segmental level. The passages are expanded, supported with the expectation that the patency is maintained by paclitaxel drug-eluting airway bypass stents. The concept of airway bypass has been demonstrated in two separate experimental studies. These studies have shown that airway bypass takes advantage of collateral ventilation present in homogeneous emphysema to allow trapped gas to escape and reduce hyperinflation. It improves lung mechanics, expiratory flow, and volume. Airway bypass stent placements have been shown to be feasible and safe in both animal and human studies. Paclitaxel-eluting airway bypass stents were found to prolong stent patency and were adopted for clinical studies. A study evaluating the early results of the clinical application of airway bypass with paclitaxel-eluting stents found that airway bypass procedures reduced hyperinflation and improved pulmonary function and dyspnea in selected subjects who have severe emphysema. The duration of benefit appeared to correlate with the degree of pretreatment hyperinflation. These preliminary clinical results supported further evaluation of the procedure and led to the EASE Trial. The EASE Trial is a prospective, multicenter, randomized, double-blind, sham-controlled study. The trial aims to evaluate the safety and effectiveness of the airway bypass to improve pulmonary function and reduce dyspnea in homogeneous emphysema subjects who have severe hyperinflation. The trial is presently ongoing worldwide, though enrollment was completed.

  6. Aerosol delivery and humidification with the Boussignac continuous positive airway pressure device.

    PubMed

    Thille, Arnaud W; Bertholon, Jean-François; Becquemin, Marie-Hélène; Roy, Monique; Lyazidi, Aissam; Lellouche, François; Pertusini, Esther; Boussignac, Georges; Maître, Bernard; Brochard, Laurent

    2011-10-01

    A simple method for effective bronchodilator aerosol delivery while administering continuing continuous positive airway pressure (CPAP) would be useful in patients with severe bronchial obstruction. To assess the effectiveness of bronchodilator aerosol delivery during CPAP generated by the Boussignac CPAP system and its optimal humidification system. First we assessed the relationship between flow and pressure generated in the mask with the Boussignac CPAP system. Next we measured the inspired-gas humidity during CPAP, with several humidification strategies, in 9 healthy volunteers. We then measured the bronchodilator aerosol particle size during CPAP, with and without heat-and-moisture exchanger, in a bench study. Finally, in 7 patients with acute respiratory failure and airway obstruction, we measured work of breathing and gas exchange after a β(2)-agonist bronchodilator aerosol (terbutaline) delivered during CPAP or via standard nebulization. Optimal humidity was obtained only with the heat-and-moisture exchanger or heated humidifier. The heat-and-moisture exchanger had no influence on bronchodilator aerosol particle size. Work of breathing decreased similarly after bronchodilator via either standard nebulization or CPAP, but P(aO(2)) increased significantly only after CPAP aerosol delivery. CPAP bronchodilator delivery decreases the work of breathing as effectively as does standard nebulization, but produces a greater oxygenation improvement in patients with airway obstruction. To optimize airway humidification, a heat-and-moisture exchanger could be used with the Boussignac CPAP system, without modifying aerosol delivery.

  7. Bubble Continuous Positive Airway Pressure Enhances Lung Volume and Gas Exchange in Preterm Lambs

    PubMed Central

    Pillow, J. Jane; Hillman, Noah; Moss, Timothy J. M.; Polglase, Graeme; Bold, Geoff; Beaumont, Chris; Ikegami, Machiko; Jobe, Alan H.

    2007-01-01

    Rationale: The technique used to provide continuous positive airway pressure (CPAP) to the newborn may influence lung function and breathing efficiency. Objectives: To compare differences in gas exchange physiology and lung injury resulting from treatment of respiratory distress with either bubble or constant pressure CPAP and to determine if the applied flow influences short-term outcomes. Methods: Lambs (133 d gestation; term is 150 d) born via cesarean section were weighed, intubated, and treated with CPAP for 3 hours. Two groups were treated with 8 L/minute applied flow using the bubble (n = 12) or the constant pressure (n = 12) technique. A third group (n = 10) received the bubble method with 12 L/minute bias flow. Measurements at study completion included arterial blood gases, oxygraphy, capnography, tidal flow, multiple breath washout, lung mechanics, static pressure–volume curves, and bronchoalveolar lavage fluid protein. Measurements and Main Results: Birth weight and arterial gas variables at 15 minutes were comparable. Flow (8 or 12 L/min) did not influence the 3-hour outcomes in the bubble group. Bubble technique was associated with a higher pH, PaO2, oxygen uptake, and area under the flow–volume curve, and a decreased alveolar protein, respiratory quotient, PaCO2, and ventilation inhomogeneity compared with the constant pressure group. Conclusions: Compared with constant pressure technique, bubble CPAP promotes enhanced airway patency during treatment of acute postnatal respiratory disease in preterm lambs and may offer protection against lung injury. PMID:17431223

  8. Peripherally Inserted Central Catheters in Pediatric Patients: To Repair or Not Repair

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gnannt, Ralph, E-mail: ralph.gnannt@usz.ch; Patel, Premal; Temple, Michael

    IntroductionPreservation of venous access in children is a major concern in pediatric interventional radiology. If a peripherally inserted central catheter (PICC) breaks, there are two options: repair the line with a repair kit or exchange the line over a wire in the interventional suite. The purpose of this study is to assess the outcome of PICC repairs in children and to compare these with the outcomes of PICC exchange.Materials and MethodsThis is a single-center, retrospective study of central line-associated bloodstream infection (CLABSI) following management of externally broken PICCs (2010–2014). The occurrence of CLABSI within 30 days after repair (Group A) ormore » exchange (Group B) of a line was analyzed, as well as PICCs exchanged following an initial and failed repair.ResultsA total of 235 PICC breaks were included in the study, of which 161 were repaired, and 116 of whom were successful (68%, Group A). No repair was performed in 74 PICCs—55/74 of these were exchanged over a wire (74%, Group B), and 19/74 lines were removed. The 30 days post-repair CLABSI rate (Group A) was 2.0 infections per 1000 catheter days, and the calculated risk was 4.3%. In comparison the 30 days post-exchange CLABSI rate (Group B) was 4.0 per 1000 catheter days and the calculated risk 10.9%. This difference was significant when adjusted for antibiotic use (OR 3.87; 95% CI 1.07–14.0, p = 0.039).ConclusionThe results of this study support repairing a broken PICC instead of removing or replacing the line.« less

  9. Urinary catheters

    MedlinePlus

    ... drainage bag. The condom catheter must be changed every day. INTERMITTENT CATHETERS You would use an intermittent catheter ... and the catheter itself with soap and water every day. Also clean the area after every bowel movement ...

  10. Hydrophilic Catheters

    PubMed Central

    2006-01-01

    Executive Summary Objective To review the evidence on the effectiveness of hydrophilic catheters for patients requiring intermittent catheterization. Clinical Need There are various reasons why a person would require catheterization, including surgery, urinary retention due to enlargement of the prostate, spinal cord injuries, or other physical disabilities. Urethral catheters are the most prevalent cause of nosocomial urinary tract infections, that is, those that start or occur in a hospital. A urinary tract infection (UTI) occurs when bacteria adheres to the opening of the urethra. Most infections arise from Escherichia coli, from the colon. The bacteria spread into the bladder, resulting in the development of an infection. The prevalence of UTIs varies with age and sex. There is a tenfold increase in incidence for females compared with males in childhood and throughout adult life until around 55 years, when the incidence of UTIs in men and women is equal, mostly as a consequence of prostatic problems in men. Investigators have reported that urethritis (inflammation of the urethra) is found in 2% to 19% of patients practising intermittent catheterization. The Technology Hydrophilic catheters have a polymer coating that binds o the surface of the catheter. When the polymer coating is submersed in water, it absorbs and binds the water to the catheter. The catheter surface becomes smooth and very slippery. This slippery surface remains intact upon insertion into the urethra and maintains lubrication through the length of the urethra. The hydrophilic coating is designed to reduce the friction, as the catheter is inserted with the intention of reducing the risk of urethral damage. It has been suggested that because the hydrophilic catheters do not require manual lubrication they are more sterile and thus less likely to cause infection. Most hydrophilic catheters are prepackaged in sterile water, or there is a pouch of sterile water that is broken and released into the

  11. [Experitoneal bladder perforation due to in-dwelling urethral catheter successfully treated by urethral drainage: a case report].

    PubMed

    Okuda, Hidenobu; Tei, Norihide; Shimizu, Kiyonori; Imazu, Tetsuo; Yoshimura, Kazuhiro; Kiyohara, Hisakazu

    2008-07-01

    Perforation of the bladder related to long-term indwelling urethral catheter is a rare and serious complication. A 85-year-old man with an indwelling urethral catheter presented severe hematuria, abdominal pain with rebound tenderness and muscular tension over the suprapubic area after the exchange of the urethral catheter. Computed tomography and cystogram revealed experitoneal bladder perforation due to indwelling catheter. Three weeks after the indwelling urethral catheter had been placed, the perforation was closed. In most cases, laparotomy and suprapubic cystostomy are performed. We describe the case of experitoneal bladder perforation successfully treated by urethral drainage.

  12. In vivo size and shape measurement of the human upper airway using endoscopic longrange optical coherence tomography

    NASA Astrophysics Data System (ADS)

    Armstrong, Julian J.; Leigh, Matthew S.; Walton, Ian D.; Zvyagin, Andrei V.; Alexandrov, Sergey A.; Schwer, Stefan; Sampson, David D.; Hillman, David R.; Eastwood, Peter R.

    2003-07-01

    We describe a long-range optical coherence tomography system for size and shape measurement of large hollow organs in the human body. The system employs a frequency-domain optical delay line of a configuration that enables the combination of high-speed operation with long scan range. We compare the achievable maximum delay of several delay line configurations, and identify the configurations with the greatest delay range. We demonstrate the use of one such long-range delay line in a catheter-based optical coherence tomography system and present profiles of the human upper airway and esophagus in vivo with a radial scan range of 26 millimeters. Such quantitative upper airway profiling should prove valuable in investigating the pathophysiology of airway collapse during sleep (obstructive sleep apnea).

  13. GuideLiner™ as guide catheter extension for the unreachable mammary bypass graft.

    PubMed

    Vishnevsky, Alec; Savage, Michael P; Fischman, David L

    2018-03-09

    Percutaneous coronary intervention (PCI) of mammary artery bypass grafts through a trans-radial (TR) approach can present unique challenges, including coaxial vessel engagement of the guiding catheter, adequate visualization of the target lesion, sufficient backup support for equipment delivery, and the ability to reach very distal lesions. The GuideLiner catheter, a rapid exchange monorail mother-in-daughter system, facilitates successful interventions in such challenging anatomy. We present a case of a patient undergoing PCI of a right internal mammary artery (RIMA) graft via TR access in whom the graft could not be engaged with any guiding catheter. Using a balloon tracking technique over a guidewire, a GuideLiner was placed as an extension of the guiding catheter and facilitated TR-PCI by overcoming technical challenges associated with difficult anatomy. © 2018 Wiley Periodicals, Inc.

  14. An Intelligent Catheter System Robotic Controlled Catheter System

    PubMed Central

    Negoro, M.; Tanimoto, M.; Arai, F.; Fukuda, T.; Fukasaku, K.; Takahashi, I.; Miyachi, S.

    2001-01-01

    Summary We have developed a novel catheter system, an intelligent catheter system, which is able to control a catheter by an externally-placed controller. This system has made from master-slave mechanism and has following three components; 1) a joy stick as a master (for operators) 2)a catheter controller as a slave (for a patient),3)a micro force sensor as a sensing device. This catheter tele-guiding system has abilities to perform intravascular procedures from the distant places. It may help to reduce the radiation exposures to the operators and also to help train young doctors. PMID:20663387

  15. Evaluation of robotic endovascular catheters for arch vessel cannulation.

    PubMed

    Riga, Celia V; Bicknell, Colin D; Hamady, Mohamad S; Cheshire, Nicholas J W

    2011-09-01

    Conventional catheter instability and embolization risk limits the adoption of endovascular therapy in patients with challenging arch anatomy. This study investigated whether arch vessel cannulation can be enhanced by a remotely steerable robotic catheter system. Seventeen clinicians with varying endovascular experience cannulated all arch vessels within two computed tomography-reconstructed pulsatile flow phantoms (bovine type I and type III aortic arches), under fluoroscopic guidance, using conventional and robotic techniques. Quantitative (catheterization times, catheter tip movements, vessel wall hits, catheter deflection) and qualitative metrics (Imperial College Complex Endovascular Cannulation Scoring Tool [IC3ST]) performance scores were compared. Robotic catheterization techniques resulted in a significant reduction in median carotid artery cannulation times and the median number of catheter tip movements for all vessels. Vessel wall contact with the aortic arch wall was reduced to a median of zero with robotic catheters. During stiff guidewire exchanges, robotic catheters maintained stability with zero deflection, independent of the distance the catheter was introduced into the carotid vessels. Overall IC3ST performance scores (interquartile range) were significantly improved using the robotic system: Type I arch score was 26/35 (20-30.8) vs 33/35 (31-34; P = .001), and type III arch score was 20.5/35 (16.5-28.5) vs 26.5/35 (23.5-28.8; P = .001). Low- and medium-volume interventionalists demonstrated an improvement in performance with robotic cannulation techniques. The high-volume intervention group did not show statistically significant improvement, but cannulation times, movements, and vessel wall hits were significantly reduced. Robotic technology has the potential to reduce the time, risk of embolization and catheter dislodgement, radiation exposure, and the manual skill required for carotid and arch vessel cannulation, while improving overall

  16. Feasibility of virtual 3-Fr percutaneous coronary intervention using standard guiding catheters

    PubMed Central

    Fujimoto, Kazuteru; Miyao, Yuji

    2014-01-01

    Introduction Recent studies have reported the efficacy of sheathless percutaneous coronary intervention (PCI) using hydrophilic-coated 5-Fr guiding catheters that are one to two Fr sizes smaller in diameter than the corresponding introducer sheath (virtual 3-Fr PCI). However, the limited number of shapes of hydrophilic-coated guiding catheters occasionally makes them difficult to engage and control. Aim To evaluate the efficacy and feasibility of virtual 3-Fr PCI using standard guiding catheters of various shapes. Material and methods We identified 35 consecutive patients with stable angina, who underwent virtual 3-Fr PCI using either hydrophilic-coated guiding catheters (Works™, Medikit, Japan) or standard guiding catheters (Heartrail™, Terumo, Japan). Results Thirty-five patients were identified (63% men; mean age 70 ±13 years). In 2 cases, hydrophilic-coated guiding catheters were exchanged to standard guiding catheters because of difficulty in engaging the target coronary arteries. Ultimately, standard guiding catheters were used in 20 patients (57%) and hydrophilic-coated catheters were used in 15 (43%). One of 20 patients treated with standard guiding catheters and 1 of 15 treated with hydrophilic-coated guiding catheters underwent the 4-in-3 “slender mother and child” PCI technique due to difficulty of stent deployment. There were no differences between the two groups in PCI procedural variables such as procedural time, fluoroscopy time, radiation dose, or contrast dye volume. There were no access site-related complications in this study. Conclusions These findings indicate that virtual 3-Fr PCI using standard guiding catheters is as efficient and safe as virtual 3-Fr PCI using hydrophilic-coated guiding catheters. PMID:25489315

  17. Airway Management and Smoke Inhalation Injury in the Burn Patient

    DTIC Science & Technology

    2009-10-01

    transtracheal catheter). In the ‘‘final stage’’ of the injury, they developed diffuse bronchiolitis, mucous plugging, peripheral airway obstruction, and lobular...10.1016/j.cps.2009.05.013 0094-1298/09/$ – see front matter. Published by Elsevier Inc. p la st ic su rg er y. th ec li ni cs .c om Report Documentation...circumferentially around the patient’s neck (see Fig. 1A, B). Also, the tube may become obstructed in patients who have copious mucous production. This may be

  18. Minimally invasive fluoroscopic percutaneous peritoneal dialysis catheter salvage.

    PubMed

    Narayan, Rajeev; Fried, Terrance; Chica, Gerardo; Schaefer, Mathew; Mullins, Daniel

    2014-06-01

    Peritoneal dialysis catheter (PDC) dysfunction can often be treated fluoroscopically by manipulation with wire, balloon or stiff stylet, saving surgical intervention for refractory cases. We describe an enhanced percutaneous approach to PDC salvage that can lead to a more definitive intervention and salvage for cases refractory to fluoroscopic manipulation. In five cases of PD catheter malfunction, the deep cuff was dissected free after a 0.035 hydrophilic wire was passed into the peritoneum through the PDC. Only the intraperitoneal portion of the PDC was explanted. The PDC was cleared of obstruction and omentum. The intraperitoneal portion of the PDC was reimplanted over wire via a peel-away sheath and the deep cuff sutured. Omental entrapment was present in three of five patients and fibrin occlusion in four of the five cases. All catheters were repaired successfully by the described technique. Post procedure, 3-5 days of lower volume, recumbent PD exchanges were performed prior to full-dose PD. No perioperative complications or leaks were noted. All PDCs were patent at 6 months. One patient required laparoscopy for recurrent omental wrapping 3 months post intervention. PDC salvage in this manner is a cost-effective alternative to laparoscopic repair of PDCs failing catheter manipulation. The infection barrier afforded by the original superficial cuff and subcutaneous tunnel is maintained. PD can be resumed immediately. Only refractory cases need laparoscopy. This procedure allows for a more definitive correction of catheter migration and obstruction, avoids placement of a new PDC or temporary hemodialysis, is cost-effective and expands percutaneous options for dysfunctional PD catheters.

  19. Mass loading of the upper airway extraluminal tissue space in rabbits: effects on tissue pressure and pharyngeal airway lumen geometry.

    PubMed

    Kairaitis, Kristina; Howitt, Lauren; Wheatley, John R; Amis, Terence C

    2009-03-01

    Lateral pharyngeal fat pad compression of the upper airway (UA) wall is thought to influence UA size in patients with obstructive sleep apnea. We examined interactions between acute mass/volume loading of the UA extra-luminal tissue space and UA patency. We studied 12 supine, anesthetized, spontaneously breathing, head position-controlled (50 degrees ), New Zealand White rabbits. Submucosal extraluminal tissue pressures (ETP) in the anterolateral (ETPlat) and anterior (ETPant) pharyngeal wall were monitored with surgically inserted pressure transducer-tipped catheters (Millar). Tracheal pressure (Ptr) and airflow (V) were measured via a pneumotachograph and pressure transducer inserted in series into the intact trachea, with hypopharyngeal cross-sectional area (CSA) measured via computed tomography, while graded saline inflation (0-1.5ml) of a compliant tissue expander balloon in the anterolateral subcutaneous tissue was performed. Inspiratory UA resistance (Rua) at 20 ml/s was calculated from a power function fitted to Ptr vs. V data. Graded expansion of the anterolateral balloon increased ETPlat from 2.3 +/- 0.5 cmH(2)O (n = 11, mean +/- SEM) to 5.0 +/- 1.1 cmH(2)O at 1.5-ml inflation (P < 0.05; ANOVA). However, ETPant was unchanged from 0.5 +/- 0.5 cmH(2)O (n = 9; P = 0.17). Concurrently, Rua increased to 119 +/- 4.2% of baseline value (n = 12; P < 0.001) associated with a significant reduction in CSA between 10 and 70% of airway length to a minimum of 82.2 +/- 4.4% of baseline CSA at 40% of airway length (P < 0.05). We conclude that anterolateral loading of the upper airway extraluminal tissue space decreases upper airway patency via an increase in ETPlat, but not ETPant. Lateral pharyngeal fat pad size may influence UA patency via increased tissue volume and pressure causing UA wall compression.

  20. Robotic positioning of standard electrophysiology catheters: a novel approach to catheter robotics.

    PubMed

    Knight, Bradley; Ayers, Gregory M; Cohen, Todd J

    2008-05-01

    Robotic systems have been developed to manipulate and position electrophysiology (EP) catheters remotely. One limitation of existing systems is their requirement for specialized catheters or sheaths. We evaluated a system (Catheter Robotics Remote Catheter Manipulation System [RCMS], Catheter Robotics, Inc., Budd Lake, New Jersey) that manipulates conventional EP catheters placed through standard introducer sheaths. The remote controller functions much like the EP catheter handle, and the system permits repeated catheter disengagement for manual manipulation without requiring removal of the catheter from the body. This study tested the hypothesis that the RCMS would be able to safely and effectively position catheters at various intracardiac sites and obtain thresholds and electrograms similar to those obtained with manual catheter manipulation. Two identical 7 Fr catheters (Blazer II; Boston Scientific Corp., Natick, Massachusetts) were inserted into the right femoral veins of 6 mongrel dogs through separate, standard 7 Fr sheaths. The first catheter was manually placed at a right ventricular endocardial site. The second catheter handle was placed in the mating holder of the RCMS and moved to approximately the same site as the first catheter using the Catheter Robotics RCMS. The pacing threshold was determined for each catheter. This sequence was performed at 2 right atrial and 2 right ventricular sites. The distance between the manually and robotically placed catheters tips was measured, and pacing thresholds and His-bundle recordings were compared. The heart was inspected at necropsy for signs of cardiac perforation or injury. Compared to manual positioning, remote catheter placement produced the same pacing threshold at 7/24 sites, a lower threshold at 11/24 sites, and a higher threshold at only 6/24 sites (p > 0.05). The average distance between catheter tips was 0.46 +/- 0.32 cm (median 0.32, range 0.13-1.16 cm). There was no difference between right atrial

  1. The Effect of Lung Stretch during Sleep on Airway Mechanics in Overweight and Obese Asthma

    PubMed Central

    Campana, L.M.; Malhotra, A.; Suki, B.; Hess, L.; Israel, E.; Smales, E.; DeYoung, P.; Owens, R.L.

    2012-01-01

    Both obesity and sleep reduce lung volume and limit deep breaths, possibly contributing to asthma. We hypothesize that increasing lung volume dynamically during sleep would reduce airway resistance in asthma. Asthma (n=10) and control (n=10) subjects were studied during sleep at baseline and with increased lung volume via bi-level positive airway pressure (BPAP). Using forced oscillations, respiratory system resistance (Rrs) and reactance (Xrs) were measured during sleep and Rrs was partitioned to upper and lower airway resistance (Rup, Rlow) using an epiglottic pressure catheter. Rrs and Rup increased with sleep (p<0.01) and Xrs was decreased in REM (p=0.02) as compared to wake. Rrs, Rup, and Rlow, were larger (p<0.01) and Xrs was decreased (p<0.02) in asthma. On BPAP, Rrs and Rup were decreased (p<0.001) and Xrs increased (p<0.01), but Rlow was unchanged. High Rup was observed in asthma, which reduced with BPAP. We conclude that the upper airway is a major component of Rrs and larger lung volume changes may be required to alter Rlow. PMID:23041446

  2. Catheter indwell time and phlebitis development during peripheral intravenous catheter administration.

    PubMed

    Pasalioglu, Kadriye Burcu; Kaya, Hatice

    2014-07-01

    Intravenous catheters have been indispensable tools of modern medicine. Although intravenous applications can be used for a multitude of purposes, these applications may cause complications, some of which have serious effects. Of these complications, the most commonly observed is phlebitis. This study was conducted to determine the effect of catheter indwell time on phlebitis development during peripheral intravenous catheter administration. This study determined the effect of catheter indwell time on phlebitis development during peripheral intravenous catheter administration. The study included a total of 103 individuals who were administered 439 catheters and satisfied the study enrollment criteria at one infectious diseases clinic in Istanbul/Turkey. Data were compiled from Patient Information Forms, Peripheral Intravenous Catheter and Therapy Information Forms, reported grades based on the Visual Infusion Phlebitis Assessment Scale, and Peripheral Intravenous Catheter Nurse Observation Forms. The data were analyzed using SPSS. Results : The mean patient age was 53.75±15.54 (standard deviation) years, and 59.2% of the study participants were men. Phlebitis was detected in 41.2% of peripheral intravenous catheters, and the rate decreased with increased catheter indwell time. Analyses showed that catheter indwell time, antibiotic usage, sex, and catheterization sites were significantly associated with development of phlebitis. The results of this study show that catheters can be used for longer periods of time when administered under optimal conditions and with appropriate surveillance.

  3. Patterns of recruitment and injury in a heterogeneous airway network model

    PubMed Central

    Stewart, Peter S.; Jensen, Oliver E.

    2015-01-01

    In respiratory distress, lung airways become flooded with liquid and may collapse due to surface-tension forces acting on air–liquid interfaces, inhibiting gas exchange. This paper proposes a mathematical multiscale model for the mechanical ventilation of a network of occluded airways, where air is forced into the network at a fixed tidal volume, allowing investigation of optimal recruitment strategies. The temporal response is derived from mechanistic models of individual airway reopening, incorporating feedback on the airway pressure due to recruitment. The model accounts for stochastic variability in airway diameter and stiffness across and between generations. For weak heterogeneity, the network is completely ventilated via one or more avalanches of recruitment (with airways recruited in quick succession), each characterized by a transient decrease in the airway pressure; avalanches become more erratic for airways that are initially more flooded. However, the time taken for complete ventilation of the network increases significantly as the network becomes more heterogeneous, leading to increased stresses on airway walls. The model predicts that the most peripheral airways are most at risk of ventilation-induced damage. A positive-end-expiratory pressure reduces the total recruitment time but at the cost of larger stresses exerted on airway walls. PMID:26423440

  4. Antimicrobial-impregnated catheters for the prevention of catheter-related bloodstream infections.

    PubMed

    Lorente, Leonardo

    2016-05-04

    Central venous catheters are commonly used in critically ill patients. Such catheterization may entail mechanical and infectious complications. The interest in catheter-related infection lies in the morbidity, mortality and costs that it involved. Numerous contributions have been made in the prevention of catheter-related infection and the current review focuses on the possible current role of antimicrobial impregnated catheters to reduce catheter-related bloodstream infections (CRBSI). There is evidence that the use of chlorhexidine-silver sulfadiazine (CHSS), rifampicin-minocycline, or rifampicin-miconazol impregnated catheters reduce the incidence of CRBSI and costs. In addition, there are some clinical circumstances associated with higher risk of CRBSI, such as the venous catheter access and the presence of tracheostomy. Current guidelines for the prevention of CRBSI recommended the use of a CHSS or rifampicin-minocycline impregnated catheter in patients whose catheter is expected to remain in place > 5 d and if the CRBSI rate has not decreased after implementation of a comprehensive strategy to reduce it.

  5. Antimicrobial-impregnated catheters for the prevention of catheter-related bloodstream infections

    PubMed Central

    Lorente, Leonardo

    2016-01-01

    Central venous catheters are commonly used in critically ill patients. Such catheterization may entail mechanical and infectious complications. The interest in catheter-related infection lies in the morbidity, mortality and costs that it involved. Numerous contributions have been made in the prevention of catheter-related infection and the current review focuses on the possible current role of antimicrobial impregnated catheters to reduce catheter-related bloodstream infections (CRBSI). There is evidence that the use of chlorhexidine-silver sulfadiazine (CHSS), rifampicin-minocycline, or rifampicin-miconazol impregnated catheters reduce the incidence of CRBSI and costs. In addition, there are some clinical circumstances associated with higher risk of CRBSI, such as the venous catheter access and the presence of tracheostomy. Current guidelines for the prevention of CRBSI recommended the use of a CHSS or rifampicin-minocycline impregnated catheter in patients whose catheter is expected to remain in place > 5 d and if the CRBSI rate has not decreased after implementation of a comprehensive strategy to reduce it. PMID:27152256

  6. Infraclavicular versus axillary nerve catheters: A retrospective comparison of early catheter failure rate.

    PubMed

    Quast, Michaela B; Sviggum, Hans P; Hanson, Andrew C; Stoike, David E; Martin, David P; Niesen, Adam D

    2018-05-01

    Continuous brachial plexus catheters are often used to decrease pain following elbow surgery. This investigation aimed to assess the rate of early failure of infraclavicular (IC) and axillary (AX) nerve catheters following elbow surgery. Retrospective study. Postoperative recovery unit and inpatient hospital floor. 328 patients who received IC or AX nerve catheters and underwent elbow surgery were identified by retrospective query of our institution's database. Data collected included unplanned catheter dislodgement, catheter replacement rate, postoperative pain scores, and opioid administration on postoperative day 1. Catheter failure was defined as unplanned dislodging within 24 h of placement or requirement for catheter replacement and evaluated using a covariate adjusted model. 119 IC catheters and 209 AX catheters were evaluated. There were 8 (6.7%) failed IC catheters versus 13 (6.2%) failed AX catheters. After adjusting for age, BMI, and gender there was no difference in catheter failure rate between IC and AX nerve catheters (p = 0.449). These results suggest that IC and AX nerve catheters do not differ in the rate of early catheter failure, despite differences in anatomic location and catheter placement techniques. Both techniques provided effective postoperative analgesia with median pain scores < 3/10 for patients following elbow surgery. Reasons other than rate of early catheter failure should dictate which approach is performed. Copyright © 2018. Published by Elsevier Inc.

  7. Catheter indwell time and phlebitis development during peripheral intravenous catheter administration

    PubMed Central

    Pasalioglu, Kadriye Burcu; Kaya, Hatice

    2014-01-01

    Objective: Intravenous catheters have been indispensable tools of modern medicine. Although intravenous applications can be used for a multitude of purposes, these applications may cause complications, some of which have serious effects. Of these complications, the most commonly observed is phlebitis. This study was conducted to determine the effect of catheter indwell time on phlebitis development during peripheral intravenous catheter administration. Methods: This study determined the effect of catheter indwell time on phlebitis development during peripheral intravenous catheter administration. The study included a total of 103 individuals who were administered 439 catheters and satisfied the study enrollment criteria at one infectious diseases clinic in Istanbul/Turkey. Data were compiled from Patient Information Forms, Peripheral Intravenous Catheter and Therapy Information Forms, reported grades based on the Visual Infusion Phlebitis Assessment Scale, and Peripheral Intravenous Catheter Nurse Observation Forms. The data were analyzed using SPSS. Results : The mean patient age was 53.75±15.54 (standard deviation) years, and 59.2% of the study participants were men. Phlebitis was detected in 41.2% of peripheral intravenous catheters, and the rate decreased with increased catheter indwell time. Analyses showed that catheter indwell time, antibiotic usage, sex, and catheterization sites were significantly associated with development of phlebitis. Conclusion: The results of this study show that catheters can be used for longer periods of time when administered under optimal conditions and with appropriate surveillance. PMID:25097505

  8. Endoscopic high-resolution auto fluorescence imaging and optical coherence tomography of airways in vivo (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Pahlevaninezhad, Hamid; Lee, Anthony; Hohert, Geoffrey; Schwartz, Carley; Shaipanich, Tawimas; Ritchie, Alexander J.; Zhang, Wei; MacAulay, Calum E.; Lam, Stephen; Lane, Pierre M.

    2016-03-01

    In this work, we present multimodal imaging of peripheral airways in vivo using an endoscopic imaging system capable of co-registered optical coherence tomography and autofluorescence imaging (OCT-AFI). This system employs a 0.9 mm diameter double-clad fiber optic-based catheter for endoscopic imaging of small peripheral airways. Optical coherence tomography (OCT) can visualize detailed airway morphology in the lung periphery and autofluorescence imaging (AFI) can visualize fluorescent tissue components such as collagen and elastin, improving the detection of airway lesions. Results from in vivo imaging of 40 patients indicate that OCT and AFI offer complementary information that may increase the ability to identify pulmonary nodules in the lung periphery and improve the safety of biopsy collection by identifying large blood vessels. AFI can rapidly visualize in vivo vascular networks using fast scanning parameters resulting in vascular-sensitive imaging with less breathing/cardiac motion artifacts compared to Doppler OCT imaging. By providing complementary information about structure and function of tissue, OCT-AFI may improve site selection during biopsy collection in the lung periphery.

  9. Use of an angiographic catheter to facilitate fluoroscopy-guided percutaneous renal access in cases with diffuse contrast extravasation.

    PubMed

    Giannakopoulos, Stilianos; Bantis, Athanasios; Kalaitzis, Christos; Touloupidis, Stavros

    2010-10-01

    Occasionally during percutaneous surgery, significant contrast extravasation obscures the field, making fluoroscopic access no longer feasible. Herein, we describe a salvage technique. The cystoscopically placed, open-end ureteral catheter is exchanged with an angled-tip angiographic catheter. With the aid of a guidewire and under fluoroscopic guidance, the tip of the catheter is placed in a posterior calix. The "bull's eye" technique is then applied to direct the needle into the tip of the catheter. This technique was used in four cases over a 7-year period. Successful access was accomplished in all cases through a middle or upper calix. The catheter serves as a target for providing access to the renal collecting system and facilitates final tract dilatation.

  10. Heat transfer analysis of catheters used for localized tissue cooling to attenuate reperfusion injury.

    PubMed

    Merrill, Thomas L; Mitchell, Jennifer E; Merrill, Denise R

    2016-08-01

    Recent revascularization success for ischemic stroke patients using stentrievers has created a new opportunity for therapeutic hypothermia. By using short term localized tissue cooling interventional catheters can be used to reduce reperfusion injury and improve neurological outcomes. Using experimental testing and a well-established heat exchanger design approach, the ɛ-NTU method, this paper examines the cooling performance of commercially available catheters as function of four practical parameters: (1) infusion flow rate, (2) catheter location in the body, (3) catheter configuration and design, and (4) cooling approach. While saline batch cooling outperformed closed-loop autologous blood cooling at all equivalent flow rates in terms of lower delivered temperatures and cooling capacity, hemodilution, systemic and local, remains a concern. For clinicians and engineers this paper provides insights for the selection, design, and operation of commercially available catheters used for localized tissue cooling. Copyright © 2016 IPEM. Published by Elsevier Ltd. All rights reserved.

  11. Transforming growth factor‐β enhances Rho‐kinase activity and contraction in airway smooth muscle via the nucleotide exchange factor ARHGEF1

    PubMed Central

    Shaifta, Yasin; MacKay, Charles E.; Irechukwu, Nneka; O'Brien, Katie A.; Wright, David B.; Ward, Jeremy P. T.

    2017-01-01

    Key points Transforming growth‐factor‐β (TGF‐β) and RhoA/Rho‐kinase are independently implicated in the airway hyper‐responsiveness associated with asthma, but how these proteins interact is not fully understood.We examined the effects of pre‐treatment with TGF‐β on expression and activity of RhoA, Rho‐kinase and ARHGEF1, an activator of RhoA, as well as on bradykinin‐induced contraction, in airway smooth muscle.TGF‐β enhanced bradykinin‐induced RhoA translocation, Rho‐kinase‐dependent phosphorylation and contraction, but partially suppressed bradykinin‐induced RhoA activity (RhoA‐GTP content).TGF‐β enhanced the expression of ARHGEF1, while a small interfering RNA against ARHGEF1 and a RhoGEF inhibitor prevented the effects of TGF‐β on RhoA and Rho‐kinase activity and contraction, respectively.ARHGEF1 expression was also enhanced in airway smooth muscle from asthmatic patients and ovalbumin‐sensitized mice.ARHGEF1 is a key TGF‐β target gene, an important regulator of Rho‐kinase activity and therefore a potential therapeutic target for the treatment of asthmatic airway hyper‐responsiveness. Abstract Transforming growth factor‐β (TGF‐β), RhoA/Rho‐kinase and Src‐family kinases (SrcFK) have independently been implicated in airway hyper‐responsiveness, but how they interact to regulate airway smooth muscle contractility is not fully understood. We found that TGF‐β pre‐treatment enhanced acute contractile responses to bradykinin (BK) in isolated rat bronchioles, and inhibitors of RhoGEFs (Y16) and Rho‐kinase (Y27632), but not the SrcFK inhibitor PP2, prevented this enhancement. In cultured human airway smooth muscle cells (hASMCs), TGF‐β pre‐treatment enhanced the protein expression of the Rho guanine nucleotide exchange factor ARHGEF1, MLC20, MYPT‐1 and the actin‐severing protein cofilin, but not of RhoA, ROCK2 or c‐Src. In hASMCs, acute treatment with BK triggered subcellular translocation

  12. Previous PICC Placement May Be Associated With Catheter-Related Infections in Hemodialysis Patients

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Butler, Philip J., E-mail: philip.butler@yale.edu; Sood, Shreya; Mojibian, Hamid

    2011-02-15

    Background: Catheter-related infections (CRIs) are a significant source of morbidity and mortality in hemodialysis patients. The identification of novel, modifiable risk factors for CRIs may lead to improved outcomes in this population. Peripherally inserted central catheters (PICCs) have been hypothesized to compromise vascular access due to vascular damage and venous thrombosis, whereas venous thrombosis has been linked to the development of CRIs. Here we examine the association between PICC placement and CRIs. Methods: A retrospective review was performed of all chronic hemodialysis catheter placements and exchanges performed at a large university hospital from September 2003 to September 2008. History ofmore » PICC line use was determined by examining hospital radiologic records from December 1993 to September 2008. Catheter-related complications were assessed and correlated with PICC line history. Results: One hundred eighty-five patients with 713 chronic tunneled hemodialysis catheter placements were identified. Thirty-eight of those patients (20.5%) had a history of PICC placement; these patients were more likely to have CRIs (odds ratio = 2.46, 95% confidence interval = 1.71-3.53, p < .001) compared with patients without a history of PICC placement. There was no difference between the two groups in age or number of catheters placed. Conclusion: Previous PICC placement may be associated with catheter-related infections in hemodialysis patients.« less

  13. Endoluminal dilatation for embedded hemodialysis catheters: A case-control study of factors associated with embedding and clinical outcomes

    PubMed Central

    Talreja, Hari; Ryan, Stephen Edward; Graham, Janet; Sood, Manish M.; Hadziomerovic, Adnan; Clark, Edward

    2017-01-01

    Background With the increasing frequency of tunneled hemodialysis catheter use there is a parallel increase in the need for removal and/or exchange. A small but significant minority of catheters become embedded or ‘stuck’ and cannot be removed by traditional means. Management of embedded catheters involves cutting the catheter, burying the retained fragment with a subsequent increased risk of infections and thrombosis. Endoluminal dilatation may provide a potential safe and effective technique for removing embedded catheters, however, to date, there is a paucity of data. Objectives 1) To determine factors associated with catheters becoming embedded and 2) to determine outcomes associated with endoluminal dilatation Methods All patients with endoluminal dilatation for embedded catheters at our institution since Jan. 2010 were included. Patients who had an embedded catheter were matched 1:3 with patients with uncomplicated catheter removal. Baseline patient and catheter characteristics were compared. Outcomes included procedural success and procedure-related infection. Logistic regression models were used to determine factors associated with embedded catheters. Results We matched 15 cases of embedded tunneled catheters with 45 controls. Among patients with embedded catheters, there were no complications with endoluminal dilatation. Factors independently associated with embedded catheters included catheter dwell time (> 2 years) and history of central venous stenosis. Conclusion Embedded catheters can be successfully managed by endoluminal dilatation with minimal complications and factors associated with embedding include dwell times > 2 years and/or with a history of central venous stenosis. PMID:28346468

  14. Hemodialysis Tunneled Catheter Noninfectious Complications

    PubMed Central

    Miller, Lisa M.; MacRae, Jennifer M.; Kiaii, Mercedeh; Clark, Edward; Dipchand, Christine; Kappel, Joanne; Lok, Charmaine; Luscombe, Rick; Moist, Louise; Oliver, Matthew; Pike, Pamela; Hiremath, Swapnil

    2016-01-01

    Noninfectious hemodialysis catheter complications include catheter dysfunction, catheter-related thrombus, and central vein stenosis. The definitions, causes, and treatment strategies for catheter dysfunction are reviewed below. Catheter-related thrombus is a less common but serious complication of catheters, requiring catheter removal and systemic anticoagulation. In addition, the risk factors, clinical manifestation, and treatment options for central vein stenosis are outlined. PMID:28270922

  15. [An efficient strategy to decrease the central venous catheter-related adverse events rate in haemodialysis patients].

    PubMed

    Jean, Guillaume; Vanel, Thierry; Bresson, Eric; Terrat, Jean-Claude; Hurot, Jean-Marc; Lorriaux, Christie; Mayor, Brice; Chazot, Charles

    2009-07-01

    Catheter-related adverse events (CAE) remain a major cause of mortality and morbidity. We aimed to compare the CAE prevalence and adverse events rate at 10 years interval in one centre using different devices, dressing procedures. We compared two periods, from 1994 to 1997 (period 1) and from 2004 to 2007 (period 2). We recorded all prevalent tunnelled CAE and their related adverse event rate: catheter-related bacteraemia (CRB), catheter local infection (CLI), catheter dysfunction leading to CAE exchange, thrombolytic use and spontaneous pulling up. In period 1, PermCath catheter (Quinton, N=63) and TwinCath catheter (MedComp, N=76) were used in 95 HD. BioFlex catheter (N=52) and ASPC split catheter (MedComp, N=52) were used in 72 HD in period 2. In period 1, we performed catheter dressing using povidone iodine versus alcoholic chlorexidine in period 2. Between period 1 and period 2, the CAE prevalence decreased from 15-18% to 9-6%, CRB from 1.1 to 0.23/1000 day-catheter (p<0.001), CLI from 1.1 to 0.28/1000 day-catheter (p<0.001), definitive dysfunction from 12 to 1.2% (p<0.001) and CAE pulling up from 4 to 0%. The annual urokinase consumption decreased from three to one unit per CAE. This study shows the dramatic decrease in CAE prevalence (-50%) and related-adverse events (approximately -200%) since 10 years. Switching povidone iodine to chlorexidine and using more recent catheter devices appear very efficient in decreasing catheter-related adverse events.

  16. Turkish nurses' level of knowledge regarding implantable port catheter care.

    PubMed

    Özden, Dilek; Çalişkan, Nurcan

    2012-06-01

    The aim of this study was to determine the knowledge levels of Turkish nurses regarding implantable port catheter care. A descriptive method was used inside a university hospital that was located in a Turkish metropolis. The data were collected via a questionnaire that was given to a total of 45 nurses who were employed in the internal medicine clinics where the oncology patients were treated. In this study, 42.2% of the nurses received in-service training about the implantable port catheter. It was determined that the mean knowledge point was 15.13 ± 4.78. The difference between the knowledge points of the nurses regarding implantable port catheter care, based on whether or not the nurses had received in-service training, was statistically significant. Moreover, it was determined that the majority of the nurses did not know where the implantable port catheter is placed, its period of use following implantation, the amount of normal saline to be used for washing the catheter, the special port (Huber) needle, the number of the needle, and the exchange time of these needles. In this study, there existed significant differences between the scores of the nurses who received in-service training about the implantable port catheter and the scores of those who did not receive in-service training. The majority of the nurses who participated in the study were willing to receive in-service training regarding this subject. Thus, the organization of in-service training programs and the implementation of care, according to the developed standards and guidelines, are considered as significant for reducing the occurrence of the complications that are related to the use of the implantable port catheter. © 2011 The Authors. Japan Journal of Nursing Science © 2011 Japan Academy of Nursing Science.

  17. Dialysis catheter associated cardiac tamponade: quick diagnosis by extemporaneous echocardiography.

    PubMed

    Ervo, R; Angeletti, S; Turrini Dertenois, L; Cavatorta, F

    2008-01-01

    We report a case of pericardial tamponade associated with over the wire exchange of a central venous catheter (CVC) for hemodialysis (HD). The complication was quickly diagnosed due to an extemporaneous echocardiogram with a linear probe, before other laboratory and radiologic tests could detect it. The described approach allowed a suitable therapy with a positive result.

  18. Nasal continuous positive airway pressure: does bubbling improve gas exchange?

    PubMed

    Morley, C J; Lau, R; De Paoli, A; Davis, P G

    2005-07-01

    In a randomised crossover trial, 26 babies, treated with Hudson prong continuous positive airway pressure (CPAP) from a bubbling bottle, received vigorous, high amplitude, or slow bubbling for 30 minutes. Pulse oximetry, transcutaneous carbon dioxide, and respiratory rate were recorded. The bubbling rates had no effect on carbon dioxide, oxygenation, or respiratory rate.

  19. Peritoneal Dialysis Catheter Insertion.

    PubMed

    Crabtree, John H; Chow, Kai-Ming

    2017-01-01

    The success of peritoneal dialysis as renal-replacement therapy depends on a well-functioning peritoneal catheter. Knowledge of best practices in catheter insertion can minimize the risk of catheter complications that lead to peritoneal dialysis failure. The catheter placement procedure begins with preoperative assessment of the patient to determine the most appropriate catheter type, insertion site, and exit site location. Preoperative preparation of the patient is an instrumental step in facilitating the performance of the procedure, avoiding untoward events, and promoting the desired outcome. Catheter insertion methods include percutaneous needle-guidewire with or without image guidance, open surgical dissection, peritoneoscopic procedure, and surgical laparoscopy. The insertion technique used often depends on the geographic availability of material resources and local provider expertise in placing catheters. Independent of the catheter implantation approach, adherence to a number of universal details is required to ensure the best opportunity for creating a successful long-term peritoneal access. Finally, appropriate postoperative care and catheter break-in enables a smooth transition to dialysis therapy. Copyright © 2017 Elsevier Inc. All rights reserved.

  20. Composition of nasal airway surface liquid in cystic fibrosis and other airway diseases determined by X-ray microanalysis.

    PubMed

    Vanthanouvong, V; Kozlova, I; Johannesson, M; Nääs, E; Nordvall, S L; Dragomir, A; Roomans, G M

    2006-04-01

    The ionic composition of the airway surface liquid (ASL) in healthy individuals and in patients with cystic fibrosis (CF) has been debated. Ion transport properties of the upper airway epithelium are similar to those of the lower airways and it is easier to collect nasal ASL from the nose. ASL was collected with ion exchange beads, and the elemental composition of nasal fluid was determined by X-ray microanalysis in healthy subjects, CF patients, CF heterozygotes, patients with rhinitis, and with primary ciliary dyskinesia (PCD). In healthy subjects, the ionic concentrations were approximately isotonic. In CF patients, CF heterozygotes, rhinitis, and PCD patients, [Na] and [Cl] were significantly higher compared when compared with those in controls. [K] was significantly higher in CF and PCD patients compared with that in controls. Severely affected CF patients had higher ionic concentrations in their nasal ASL than in patients with mild or moderate symptoms. Female CF patients had higher levels of Na, Cl, and K than male patients. As higher salt concentrations in the ASL are also found in other patients with airway diseases involving chronic inflammation, it appears likely that inflammation-induced epithelial damage is important in determining the ionic composition of the ASL. Copyright (c) 2006 Wiley-Liss, Inc.

  1. Compensation for Unconstrained Catheter Shaft Motion in Cardiac Catheters

    PubMed Central

    Degirmenci, Alperen; Loschak, Paul M.; Tschabrunn, Cory M.; Anter, Elad; Howe, Robert D.

    2016-01-01

    Cardiac catheterization with ultrasound (US) imaging catheters provides real time US imaging from within the heart, but manually navigating a four degree of freedom (DOF) imaging catheter is difficult and requires extensive training. Existing work has demonstrated robotic catheter steering in constrained bench top environments. Closed-loop control in an unconstrained setting, such as patient vasculature, remains a significant challenge due to friction, backlash, and physiological disturbances. In this paper we present a new method for closed-loop control of the catheter tip that can accurately and robustly steer 4-DOF cardiac catheters and other flexible manipulators despite these effects. The performance of the system is demonstrated in a vasculature phantom and an in vivo porcine animal model. During bench top studies the robotic system converged to the desired US imager pose with sub-millimeter and sub-degree-level accuracy. During animal trials the system achieved 2.0 mm and 0.65° accuracy. Accurate and robust robotic navigation of flexible manipulators will enable enhanced visualization and treatment during procedures. PMID:27525170

  2. AGONIST-MEDIATED AIRWAY CHALLENGE: CARDIOPULMONARY INTERACTIONS MODULATE GAS EXCHANGE AND RECOVERY

    EPA Science Inventory

    ABSTRACT
    To better understand the early phase response (0-60 minutes) to airway challenge, we examined cardiopulmonary reactions during ovalbumin (OVA), histamine, and methacholine aerosol challenge tests in guinea pigs. Propranolol and 100% O2 were used to modify the reacti...

  3. Catheter-related bloodstream infection.

    PubMed

    Goede, Matthew R; Coopersmith, Craig M

    2009-04-01

    Catheter-related bloodstream infections (CR-BSIs) are a common, frequently preventable complication of central venous catheterization. CR-BSIs can be prevented by strict attention to insertion and maintenance of central venous catheters and removing unneeded catheters as soon as possible. Antiseptic- or antibiotic-impregnated catheters are also an effective tool to prevent infections. The diagnosis of CR-BSI is made largely based on culture results. CR-BSIs should always be treated with antibiotics, and except in rare circumstances the infected catheter needs to be removed.

  4. Clinical implications of acute pelvicaliceal hematoma formation during percutaneous catheter nephrostomy insertion.

    PubMed

    Stewart, Jessica K; Smith, Tony P; Kim, Charles Y

    To determine the clinical implications of acute pelvicaliceal hematoma formation during percutaneous catheter nephrostomy (PCN) insertion. Collecting system hematoma burden was retrospectively assessed for 694 PCN insertions in 502 patients. Pelvicaliceal hematoma formation occurred in 146 kidneys (21%) in 136 patients. Clinically significant blood loss occurred in 3 patients with hematomas within one week compared to 4 patients without hematomas (p=0.39). Twenty-four patients with hematomas underwent catheter exchange within one week, compared to 55 patients without hematomas (p=0.49). Pelvicaliceal hematoma formation after PCN insertion is not uncommon and is associated with very rare clinical sequelae. Copyright © 2017 Elsevier Inc. All rights reserved.

  5. A central venous catheter coated with benzalkonium chloride for the prevention of catheter-related microbial colonization.

    PubMed

    Moss, H A; Tebbs, S E; Faroqui, M H; Herbst, T; Isaac, J L; Brown, J; Elliott, T S

    2000-11-01

    In an attempt to overcome infections associated with central venous catheters, a new antiseptic central venous catheter coated with benzalkonium chloride on the internal and external surfaces has been developed and evaluated in a clinical trial. Patients (235) randomly received either a triple-lumen central venous catheter coated with benzalkonium chloride (117) or a polyurethane non-antiseptic catheter (118). The incidence of microbial colonization of both catheters and retained antiseptic activity of the benzalkonium chloride device following removal were determined. The benzalkonium chloride resulted in a significant reduction of the incidence of microbial colonization on both the internal and external catheter surfaces. The reduction in colonization was detected at both the intradermal (21 benzalkonium chloride catheters vs. 38 controls, P = 0.0016) and distal segments of the antiseptic-coated catheters. Following catheter removal retained activity was demonstrated in benzalkonium chloride catheters which had been in place for up to 12 days. No patients developed adverse reactions to the benzalkonium chloride catheters. The findings demonstrate that the benzalkonium chloride catheter significantly reduced the incidence of catheter-associated colonization.

  6. Catheter associated urinary tract infections

    PubMed Central

    2014-01-01

    Urinary tract infection attributed to the use of an indwelling urinary catheter is one of the most common infections acquired by patients in health care facilities. As biofilm ultimately develops on all of these devices, the major determinant for development of bacteriuria is duration of catheterization. While the proportion of bacteriuric subjects who develop symptomatic infection is low, the high frequency of use of indwelling urinary catheters means there is a substantial burden attributable to these infections. Catheter-acquired urinary infection is the source for about 20% of episodes of health-care acquired bacteremia in acute care facilities, and over 50% in long term care facilities. The most important interventions to prevent bacteriuria and infection are to limit indwelling catheter use and, when catheter use is necessary, to discontinue the catheter as soon as clinically feasible. Infection control programs in health care facilities must implement and monitor strategies to limit catheter-acquired urinary infection, including surveillance of catheter use, appropriateness of catheter indications, and complications. Ultimately, prevention of these infections will require technical advances in catheter materials which prevent biofilm formation. PMID:25075308

  7. Postoperative Chylothorax of Unclear Etiology in a Patient with Right-sided Subclavian Central Venous Catheter Placement

    PubMed Central

    Asghar, Samie; Shamim, Faisal

    2017-01-01

    A young male underwent decompressive craniotomy for an intracerebral bleed. A right-sided subclavian central venous catheter was placed in the operating room after induction of anesthesia. Postoperatively, he was shifted to Intensive Care Unit (ICU) for mechanical ventilation due to low Glasgow coma scale. He had an episode of severe agitation and straining on the tracheal tube in the evening same day. On the 2nd postoperative day in ICU, his airway pressures were high, and chest X-ray revealed massive pleural effusion on right side. Under ultrasound guidance, 1400 milky white fluid was aspirated. It was sent for analysis (triglycerides) that confirmed chyle and hence, chylothorax was made as diagnosis. A duplex scan was done which ruled out thrombosis in subclavian vein. The catheter had normal pressure tracing with free aspiration of blood from all ports. Enteral feeding was continued as it is a controversial matter in the literature and he was monitored clinically and radiologically. PMID:29284881

  8. Postoperative Chylothorax of Unclear Etiology in a Patient with Right-sided Subclavian Central Venous Catheter Placement.

    PubMed

    Asghar, Samie; Shamim, Faisal

    2017-01-01

    A young male underwent decompressive craniotomy for an intracerebral bleed. A right-sided subclavian central venous catheter was placed in the operating room after induction of anesthesia. Postoperatively, he was shifted to Intensive Care Unit (ICU) for mechanical ventilation due to low Glasgow coma scale. He had an episode of severe agitation and straining on the tracheal tube in the evening same day. On the 2 nd postoperative day in ICU, his airway pressures were high, and chest X-ray revealed massive pleural effusion on right side. Under ultrasound guidance, 1400 milky white fluid was aspirated. It was sent for analysis (triglycerides) that confirmed chyle and hence, chylothorax was made as diagnosis. A duplex scan was done which ruled out thrombosis in subclavian vein. The catheter had normal pressure tracing with free aspiration of blood from all ports. Enteral feeding was continued as it is a controversial matter in the literature and he was monitored clinically and radiologically.

  9. Mechanics of airway and alveolar collapse in human breath-hold diving.

    PubMed

    Fitz-Clarke, John R

    2007-11-15

    A computational model of the human respiratory tract was developed to study airway and alveolar compression and re-expansion during deep breath-hold dives. The model incorporates the chest wall, supraglottic airway, trachea, branched airway tree, and elastic alveoli assigned time-dependent surfactant properties. Total lung collapse with degassing of all alveoli is predicted to occur around 235 m, much deeper than estimates for aquatic mammals. Hysteresis of the pressure-volume loop increases with maximum diving depth due to progressive alveolar collapse. Reopening of alveoli occurs stochastically as airway pressure overcomes adhesive and compressive forces on ascent. Surface area for gas exchange vanishes at collapse depth, implying that the risk of decompression sickness should reach a plateau beyond this depth. Pulmonary capillary transmural stresses cannot increase after local alveolar collapse. Consolidation of lung parenchyma might provide protection from capillary injury or leakage caused by vascular engorgement due to outward chest wall recoil at extreme depths.

  10. Use of peripherally inserted central catheters as an alternative to central catheters in neurocritical care units.

    PubMed

    DeLemos, Christi; Abi-Nader, Judy; Akins, Paul T

    2011-04-01

    Patients in neurological critical care units often have lengthy stays that require extended vascular access and invasive hemodynamic monitoring. The traditional approach for these patients has relied heavily on central venous and pulmonary artery catheters. The aim of this study was to evaluate peripherally inserted central catheters as an alternative to central venous catheters in neurocritical care settings. Data on 35 patients who had peripherally inserted central catheters rather than central venous or pulmonary artery catheters for intravascular access and monitoring were collected from a prospective registry of neurological critical care admissions. These data were cross-referenced with information from hospital-based data registries for peripherally inserted central catheters and subarachnoid hemorrhage. Complete data were available on 33 patients with Hunt-Hess grade IV-V aneurysmal subarachnoid hemorrhage. Catheters remained in place a total of 649 days (mean, 19 days; range, 4-64 days). One patient (3%) had deep vein thrombosis in an upper extremity. In 2 patients, central venous pressure measured with a peripherally inserted catheter was higher than pressure measured concurrently with a central venous catheter. None of the 33 patients had a central catheter bloodstream infection or persistent insertion-related complications. CONCLUSIONS Use of peripherally inserted central catheters rather than central venous catheters or pulmonary artery catheters in the neurocritical care unit reduced procedural and infection risk without compromising patient management.

  11. A three-microphone acoustic reflection technique using transmitted acoustic waves in the airway.

    PubMed

    Fujimoto, Yuki; Huang, Jyongsu; Fukunaga, Toshiharu; Kato, Ryo; Higashino, Mari; Shinomiya, Shohei; Kitadate, Shoko; Takahara, Yutaka; Yamaya, Atsuyo; Saito, Masatoshi; Kobayashi, Makoto; Kojima, Koji; Oikawa, Taku; Nakagawa, Ken; Tsuchihara, Katsuma; Iguchi, Masaharu; Takahashi, Masakatsu; Mizuno, Shiro; Osanai, Kazuhiro; Toga, Hirohisa

    2013-10-15

    The acoustic reflection technique noninvasively measures airway cross-sectional area vs. distance functions and uses a wave tube with a constant cross-sectional area to separate incidental and reflected waves introduced into the mouth or nostril. The accuracy of estimated cross-sectional areas gets worse in the deeper distances due to the nature of marching algorithms, i.e., errors of the estimated areas in the closer distances accumulate to those in the further distances. Here we present a new technique of acoustic reflection from measuring transmitted acoustic waves in the airway with three microphones and without employing a wave tube. Using miniaturized microphones mounted on a catheter, we estimated reflection coefficients among the microphones and separated incidental and reflected waves. A model study showed that the estimated cross-sectional area vs. distance function was coincident with the conventional two-microphone method, and it did not change with altered cross-sectional areas at the microphone position, although the estimated cross-sectional areas are relative values to that at the microphone position. The pharyngeal cross-sectional areas including retropalatal and retroglossal regions and the closing site during sleep was visualized in patients with obstructive sleep apnea. The method can be applicable to larger or smaller bronchi to evaluate the airspace and function in these localized airways.

  12. Initial Experience and Feasibility of the New Low-Profile Stingray Catheter as Part of the Antegrade Dissection and Re-Entry Revascularization Strategy for Coronary Chronic Total Occlusions.

    PubMed

    Maeremans, Joren; Palmers, Pieter-Jan; Dens, Joseph

    2017-01-31

    BACKGROUND During antegrade dissection re-entry (ADR) of chronic total occlusions (CTO), the first-generation Stingray catheter requires the use of large-bore guides (sheathless 7.5 Fr or 8 Fr), which increases the risk for access site-related complications and compromises radial approaches. Smaller guiding sizes necessitate long guidewires (e.g., 300 cm) or guidewire extensions for catheter advancement or removal. However, friction between guides and the Stingray catheter can result in unstable guidewire position or unintentional removal. Furthermore, failure to deliver the catheter at the distal re-entry zone is a common problem. To overcome issues of deliverability and reduce the need for pre-dilatations, with its inherent risk of creating subintimal hematomas, the Stingray low-profile (LP) balloon catheter was developed. CASE REPORT We describe 3 cases of successful application of the novel Stingray LP catheter during ADR. In all cases, 7 Fr guiding catheters were successfully used in combination with the device. The lower profile facilitated a good exchange and delivery of the device, without the need for balloon pre-dilatations in 2 cases. This resulted in a limited subintimal plane, enabling a smooth puncture into the true lumen. One case presented with extreme levels of calcification and tortuosity, resulting in a high degree of friction, despite the lower catheter profile. No in-hospital coronary or access site-related complications occurred. CONCLUSIONS This case report illustrates the feasibility of the Stingray LP catheter for the treatment of CTOs via the ADR technique. The lower profile of the catheter potentially increases the deliverability, safety, and exchangeability of the device.

  13. Tracheal gas insufflation combined with high-frequency oscillatory ventilation.

    PubMed

    Dolan, S; Derdak, S; Solomon, D; Farmer, C; Johanningman, J; Gelineau, J; Smith, R B

    1996-03-01

    To determine the efficacy of tracheal insufflation delivered by two different catheter designs on CO2 elimination when used in conjunction with high-frequency oscillatory ventilation. A nonrandomized before and after trial. Each animal served as his own control. Ten mongrel dogs weighing 20.9 +/- 1.9 kg. Four animals were assigned to a normal lung group and six animals underwent lung injury by large volume saline lavage. Permissive hypercapnia was allowed to occur by selecting oscillator settings that would lead to alveolar hypoventilation. Proximal mean airway pressure was kept constant. Tracheal gas was insufflated at 1 cm above the carina for 30 min periods at gas flows of 5 to 15 L/min. Carinal pressure, hemodynamic parameters (cardiac output, mean arterial pressure, pulmonary artery occlusion pressure), and gas exchange parameters (PaCO2, PaO2, PaO2/FIO2, shunt fraction, D O2) were measured. For the normal dogs, at catheter flow of 15 L/min; the forward thrust catheter increased carinal pressure and Pao2/FIO2 BY 30% (p<.003) and 105% (p<.005), respectively. The forward thrust catheter reduced Paco2 by 40% (p<.04). The reverse thrust catheter increased PaO2/FIO2 by 102% (p<.001) and decreased pressure and PaCO2 by 44% (p<.001) and 34% (p<.003), respectively. For the injured dogs, at catheter flow rate of 15 L/min, the forward thrust catheter increased carinal pressure, PaO2, and PaO2/FIO2 by 6% (p<.001), 23% (p<.001), and 24% (p<.02), respectively. The forward thrust catheter reduced PaCO2 by 29% (p<.002). The reverse thrust catheter increased PaO2 and PaO2/FIO2 both by 11% (p<.02) and reduced carinal pressure and PaCO2 by 23% (p<.001) and 18% (p<.002), respectively. Tracheal gas insufflation is capable of improving oxygenation and ventilation in acute lung injury when combined with high-frequency oscillatory ventilation. The addition of this second gas flow at the level of the carina raises or lowers distal airway pressure, the magnitude of which is dependent

  14. PRE-INOCULATION OF URINARY CATHETERS WITH ESCHERICHIA COLI 83972 INHIBITS CATHETER COLONIZATION BY ENTEROCOCCUS FAECALIS

    PubMed Central

    TRAUTNER, BARBARA W.; DAROUICHE, RABIH O.; HULL, RICHARD A.; HULL, SHEILA; THORNBY, JOHN I.

    2010-01-01

    Purpose The capacity of a preexisting coating of Escherichia coli 83972 to reduce catheter colonization by Enterococcus faecalis 210 was investigated. Enterococcus was chosen for these trials since it is a common urinary pathogen in patients with an indwelling urinary catheter. Materials and Methods Each experiment tested 3 growth conditions. Group 1 or E. coli plus Enterococcus catheters were exposed to E. coli 83972 for 24 hours and then to Enterococcus for 30 minutes. Group 2 or E. coli alone catheters were incubated in E. coli for 24 hours and then in sterile broth for 30 minutes. Group 3 or Enterococcus alone catheters did not undergo the initial incubation with E. coli before the 30-minute incubation with Enterococcus: All catheters were then incubated in sterile human urine for 24 hours. Catheters were washed with saline and cut into 5, 1 cm. segments. Each segment was sonicated and the sonication fluid was diluted and plated. The results of each of the 5 segments were averaged and the set of experiments was repeated 7 times. Results A preexisting coating of E. coli 83972 reduced catheter colonization by E. faecalis 210 more than 10-fold. Enterococcus alone catheters had a median of 9.7 × 105 enterococci per cm., whereas E. coli plus Enterococcus catheters had a median of 0.38 × 105 enterococci per cm. (p = 0.016). Conclusions Pre-inoculating urinary catheters with E. coli 83972 significantly impedes catheter colonization by Enterococcus: These promising in vitro results prompt the clinical investigation of this particular application of bacterial interference. PMID:11743359

  15. Transtracheal ventilation with a novel ejector-based device (Ventrain) in open, partly obstructed, or totally closed upper airways in pigs.

    PubMed

    Paxian, M; Preussler, N P; Reinz, T; Schlueter, A; Gottschall, R

    2015-08-01

    Transtracheal access and subsequent jet ventilation are among the last options in a 'cannot intubate-cannot oxygenate' scenario. These interventions may lead to hypercapnia, barotrauma, and haemodynamic failure in the event of an obstructed upper airway. The aim of the present study was to evaluate the efficacy and the haemodynamic effects of the Ventrain, a manually operated ventilation device that provides expiratory ventilation assistance. Transtracheal ventilation was carried out with the Ventrain in different airway scenarios in live pigs, and its performance was compared with a conventional jet ventilator. Pigs with open, partly obstructed, or completely closed upper airways were transtracheally ventilated either with the Ventrain or by conventional jet ventilation. Airway pressures, haemodynamic parameters, and blood gases obtained in the different settings were compared. Mean (SD) alveolar minute ventilation as reflected by arterial partial pressure of CO2 was superior with the Ventrain in partly obstructed airways after 6 min in comparison with traditional manual jet ventilation [4.7 (0.19) compared with 7.1 (0.37) kPa], and this was also the case in all simulated airway conditions. At the same time, peak airway pressures were significantly lower and haemodynamic parameters were altered to a lesser extent with the Ventrain. The results of this study suggest that the Ventrain device can ensure sufficient oxygenation and ventilation through a small-bore transtracheal catheter when the airway is open, partly obstructed, or completely closed. Minute ventilation and avoidance of high airway pressures were superior in comparison with traditional hand-triggered jet ventilation, particularly in the event of complete upper airway obstruction. © The Author 2015. Published by Oxford University Press on behalf of the British Journal of Anaesthesia. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  16. The contribution of airway smooth muscle to airway narrowing and airway hyperresponsiveness in disease.

    PubMed

    Martin, J G; Duguet, A; Eidelman, D H

    2000-08-01

    Airway hyperresponsiveness (AHR), the exaggerated response to constrictor agonists in asthmatic subjects, is incompletely understood. Changes in either the quantity or properties of airway smooth muscle (ASM) are possible explanations for AHR. Morphometric analyses demonstrate structural changes in asthmatic airways, including subepithelial fibrosis, gland hyperplasia/hypertrophy, neovascularization and an increase in ASM mass. Mathematical modelling of airway narrowing suggests that, of all the changes in structure, the increase in ASM mass is the most probable cause of AHR. An increase in ASM mass in the large airways is more closely associated with a greater likelihood of dying from asthma than increases in ASM mass in other locations within the airway tree. ASM contraction is opposed by the elastic recoil of the lungs and airways, which appears to limit the degree of bronchoconstriction in vivo. The cyclical nature of tidal breathing applies stresses to the airway wall that enhance the bronchodilating influence of the lung tissues on the contracting ASM, in all probability by disrupting cross-bridges. However, the increase in ASM mass in asthma may overcome the limitation resulting from the impedances to ASM shortening imposed by the lung parenchyma and airway wall tissues. Additionally, ASM with the capacity to shorten rapidly may achieve shorter lengths and cause a greater degree of bronchoconstriction when stimulated to contract than slower ASM. Changes in ASM properties are induced by the process of sensitization and allergen-exposure such as enhancement of phospholipase C activity and inositol phosphate turnover, and increases in myosin light chain kinase activity. Whether changes in ASM mass or biochemical/biomechanical properties form the basis for asthma remains to be determined.

  17. A mechanical design principle for tissue structure and function in the airway tree.

    PubMed

    LaPrad, Adam S; Lutchen, Kenneth R; Suki, Béla

    2013-01-01

    With every breath, the dynamically changing mechanical pressures must work in unison with the cells and soft tissue structures of the lung to permit air to efficiently traverse the airway tree and undergo gas exchange in the alveoli. The influence of mechanics on cell and tissue function is becoming apparent, raising the question: how does the airway tree co-exist within its mechanical environment to maintain normal cell function throughout its branching structure of diminishing dimensions? We introduce a new mechanical design principle for the conducting airway tree in which mechanotransduction at the level of cells is driven to orchestrate airway wall structural changes that can best maintain a preferred mechanical microenvironment. To support this principle, we report in vitro radius-transmural pressure relations for a range of airway radii obtained from healthy bovine lungs and model the data using a strain energy function together with a thick-walled cylinder description. From this framework, we estimate circumferential stresses and incremental Young's moduli throughout the airway tree. Our results indicate that the conducting airways consistently operate within a preferred mechanical homeostatic state, termed mechanical homeostasis, that is characterized by a narrow range of circumferential stresses and Young's moduli. This mechanical homeostatic state is maintained for all airways throughout the tree via airway wall dimensional and mechanical relationships. As a consequence, cells within the airway walls throughout the airway tree experience similar oscillatory strains during breathing that are much smaller than previously thought. Finally, we discuss the potential implications of how the maintenance of mechanical homeostasis, while facilitating healthy tissue-level alterations necessary for maturation, may lead to airway wall structural changes capable of chronic asthma.

  18. A Mechanical Design Principle for Tissue Structure and Function in the Airway Tree

    PubMed Central

    LaPrad, Adam S.; Lutchen, Kenneth R.; Suki, Béla

    2013-01-01

    With every breath, the dynamically changing mechanical pressures must work in unison with the cells and soft tissue structures of the lung to permit air to efficiently traverse the airway tree and undergo gas exchange in the alveoli. The influence of mechanics on cell and tissue function is becoming apparent, raising the question: how does the airway tree co-exist within its mechanical environment to maintain normal cell function throughout its branching structure of diminishing dimensions? We introduce a new mechanical design principle for the conducting airway tree in which mechanotransduction at the level of cells is driven to orchestrate airway wall structural changes that can best maintain a preferred mechanical microenvironment. To support this principle, we report in vitro radius-transmural pressure relations for a range of airway radii obtained from healthy bovine lungs and model the data using a strain energy function together with a thick-walled cylinder description. From this framework, we estimate circumferential stresses and incremental Young's moduli throughout the airway tree. Our results indicate that the conducting airways consistently operate within a preferred mechanical homeostatic state, termed mechanical homeostasis, that is characterized by a narrow range of circumferential stresses and Young's moduli. This mechanical homeostatic state is maintained for all airways throughout the tree via airway wall dimensional and mechanical relationships. As a consequence, cells within the airway walls throughout the airway tree experience similar oscillatory strains during breathing that are much smaller than previously thought. Finally, we discuss the potential implications of how the maintenance of mechanical homeostasis, while facilitating healthy tissue-level alterations necessary for maturation, may lead to airway wall structural changes capable of chronic asthma. PMID:23737742

  19. Indwelling catheter care

    MedlinePlus

    ... it overnight. You will be shown how to disconnect the bags from the Foley catheter in order ... bags through a separate valve without needing to disconnect the bag from the Foley catheter. Making Sure ...

  20. [Airway humidification practices in Chilean intensive care units].

    PubMed

    Retamal, Jaime; Castillo, Juan; Bugedo, Guillermo; Bruhn, Alejandro

    2012-11-01

    In patients with an artificial airway, inspired gases can be humidified and heated using a passive (heat and moisture exchange filter - HMEF), or an active system (heated humidifier). To assess how humidification is carried out and what is the usual clinical practice in this field in Chilean intensive care units (ICUs). A specific survey to evaluate humidification system features as well as caregivers' preferences regarding humidification systems, was carried out on the same day in all Chilean ICUs. Fifty-five ICUs were contacted and 44 of them completed the survey. From a total of 367 patients, 254 (69%) required humidification because they were breathing through an artificial airway. A heated humidifier was employed only in 12 patients (5%). Forty-three ICUs (98%) used HMEF as their routine humidification system. In 52% of surveyed ICUs, heated humidifiers were not available. In Chile the main method to humidify and heat inspired gases in patients with an artificial airway is the HMEF. Although there are clear indications for the use of heated humidifiers, they are seldom employed.

  1. Prospective comparison of two management strategies of central venous catheters in burn patients.

    PubMed

    Kealey, G P; Chang, P; Heinle, J; Rosenquist, M D; Lewis, R W

    1995-03-01

    Central venous catheters (CVCs) are associated with sepsis in burn patients. This study was undertaken to compare two strategies of CVC management in patients with major burn injuries. Forty-two burn patients with major burn injuries were randomly assigned to undergo site change every 48 hours of the CVC or to undergo wire guide exchange of the CVC every 48 hours at the same site. Catheter insertion site, distance from the burn wound, cultures of catheter tips, and blood cultures were obtained from all patients in a prospective manner. There was no difference in the incidence of CVC sepsis between the two groups studied. CVCs inserted less than 5 cm from the burn wound developed bacterial contamination at an earlier time than CVCs inserted more than 5 cm from the burn wound. There was no advantage to changing the CVC insertion site every 48 hours. Changing the CVC using the wire guide technique did not prevent, nor predict, CVC bacterial contamination.

  2. Candida spp. airway colonization: A potential risk factor for Acinetobacter baumannii ventilator-associated pneumonia.

    PubMed

    Tan, Xiaojiang; Zhu, Song; Yan, Dongxing; Chen, Weiping; Chen, Ruilan; Zou, Jian; Yan, Jingdong; Zhang, Xiangdong; Farmakiotis, Dimitrios; Mylonakis, Eleftherios

    2016-08-01

    This retrospective study was conducted to identify potential risk factors for Acinetobacter baumannii (A. baumannii) ventilator-associated pneumonia (VAP) and evaluate the association between Candida spp. airway colonization and A. baumannii VAP. Intensive care unit (ICU) patients who were on mechanical ventilation (MV) for ≥48 hours were divided into the following groups: patients with and without Candida spp. airway colonization; colonized patients receiving antifungal treatment or not; patients with A. baumannii VAP and those without VAP. Logistic regression analysis and propensity score matching were used to identify factors independently associated with A. baumannii VAP. Among 618 eligible patients, 264 (43%) had Candida spp. airway colonization and 114 (18%) developed A. baumannii VAP. Along with MV for ≥7 days (adjusted odds ratio [aOR] 8.9, 95% confidence intervals [95% CI] 4.9-15.8) and presence of a central venous catheter (aOR 3.2, 95% CI 1.1-9), Candida spp. airway colonization (aOR 2.6, 95% CI 1.6-4.3) was identified as an independent risk factor for A. baumannii VAP. Patients with Candida spp. airway colonization were more likely to develop A. baumannii VAP than non-colonized patients (23% vs 15%, P=.01 and 34% vs. 15%, P<.001 in propensity score-matched subgroups). Administration of antifungal agents was not associated with A. baumannii VAP (29% vs. 21%, P=.153) but with higher in-hospital mortality (53% vs. 39%, P=.037). Candida spp. airway colonization (43%) and A. baumannii VAP (18%) were common in ICU patients who were on mechanical ventilation for at least 48 hours. Candida spp. airway colonization was an independent risk factor for subsequent A. baumannii VAP. © The Author 2016. Published by Oxford University Press on behalf of The International Society for Human and Animal Mycology. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  3. Determining the best catheter for sonohysterography.

    PubMed

    Dessole, S; Farina, M; Capobianco, G; Nardelli, G B; Ambrosini, G; Meloni, G B

    2001-09-01

    To compare the characteristics of six different catheters for performing sonohysterography (SHG) to identify those that offer the best compromise between reliability, tolerability, and cost. Prospective study. University hospital. Six hundred ten women undergoing SHG. We performed SHG with six different types of catheters: Foleycath (Wembley Rubber Products, Sepang, Malaysia), Hysca Hysterosalpingography Catheter (GTA International Medical Devices S.A., La Caleta D.N., Dominican Republic), H/S Catheter Set (Ackrad Laboratories, Cranford, NJ), PBN Balloon Hystero-Salpingography Catheter (PBN Medicals, Stenloese, Denmark), ZUI-2.0 Catheter (Zinnanti Uterine Injection; BEI Medical System International, Gembloux, Belgium), and Goldstein Catheter (Cook, Spencer, IN). We assessed the reliability, the physician's ease of use, the time requested for the insertion of the catheter, the volume of contrast medium used, the tolerability for the patients, and the cost of the catheters. In 568 (93%) correctly performed procedures, no statistically significant differences were found among the catheters. The Foleycath was the most difficult for the physician to use and required significantly more time to position correctly. The Goldstein catheter was the best tolerated by the patients. The Foleycath was the cheapest whereas the PBN Balloon was the most expensive. The choice of the catheter must be targeted to achieving a good balance between tolerability for the patients, efficacy, cost, and the personal preference of the operator.

  4. Determination of airway humidification in high-frequency oscillatory ventilation using an artificial neonatal lung model. Comparison of a heated humidifier and a heat and moisture exchanger.

    PubMed

    Schiffmann, H; Singer, S; Singer, D; von Richthofen, E; Rathgeber, J; Züchner, K

    1999-09-01

    Thus far only few data are available on airway humidification during high-frequency oscillatory ventilation (HFOV). Therefore, we studied the performance and efficiency of a heated humidifier (HH) and a heat and moisture exchanger (HME) in HFOV using an artificial lung model. Experiments were performed with a pediatric high-frequency oscillatory ventilator. The artificial lung contained a sponge saturated with water to simulate evaporation and was placed in an incubator heated to 37 degrees C to prevent condensation. The airway humidity was measured using a capacitive humidity sensor. The water loss of the lung model was determined gravimetrically. The water loss of the lung model varied between 2.14 and 3.1 g/h during active humidification; it was 2.85 g/h with passive humidification and 7.56 g/h without humidification. The humidity at the tube connector varied between 34. 2 and 42.5 mg/l, depending on the temperature of the HH and the ventilator setting during active humidification, and between 37 and 39.9 mg/l with passive humidification. In general, HH and HME are suitable devices for airway humidification in HFOV. The performance of the ventilator was not significantly influenced by the mode of humidification. However, the adequacy of humidification and safety of the HME remains to be demonstrated in clinical practice.

  5. Trefoil factor-2 reverses airway remodeling changes in allergic airways disease.

    PubMed

    Royce, Simon G; Lim, Clarice; Muljadi, Ruth C; Samuel, Chrishan S; Ververis, Katherine; Karagiannis, Tom C; Giraud, Andrew S; Tang, Mimi L K

    2013-01-01

    Trefoil factor 2 (TFF2) is a small peptide with an important role in mucosal repair. TFF2 is up-regulated in asthma, suggesting a role in asthma pathogenesis. Given its known biological role in promoting epithelial repair, TFF2 might be expected to exert a protective function in limiting the progression of airway remodeling in asthma. The contribution of TFF2 to airway remodeling in asthma was investigated by examining the expression of TFF2 in the airway and lung, and evaluating the effects of recombinant TFF2 treatment on established airway remodeling in a murine model of chronic allergic airways disease (AAD). BALB/c mice were sensitized and challenged with ovalbumin (OVA) or saline for 9 weeks, whereas mice with established OVA-induced AAD were treated with TFF2 or vehicle control (intranasally for 14 d). Effects on airway remodeling, airway inflammation, and airway hyperresponsiveness were then assessed, whereas TFF2 expression was determined by immunohistochemistry. TFF2 expression was significantly increased in the airways of mice with AAD, compared with expression levels in control mice. TFF2 treatment resulted in reduced epithelial thickening, subepithelial collagen deposition, goblet-cell metaplasia, bronchial epithelium apoptosis, and airway hyperresponsiveness (all P < 0.05, versus vehicle control), but TFF2 treatment did not influence airway inflammation. The increased expression of endogenous TFF2 in response to chronic allergic inflammation is insufficient to prevent the progression of airway inflammation and remodeling in a murine model of chronic AAD. However, exogenous TFF2 treatment is effective in reversing aspects of established airway remodeling. TFF2 has potential as a novel treatment for airway remodeling in asthma.

  6. Exploring relationships of catheter-associated urinary tract infection and blockage in people with long-term indwelling urinary catheters.

    PubMed

    Wilde, Mary H; McMahon, James M; Crean, Hugh F; Brasch, Judith

    2017-09-01

    To describe and explore relationships among catheter problems in long-term indwelling urinary catheter users, including excess healthcare use for treating catheter problems. Long-term urinary catheter users experience repeated problems with catheter-related urinary tract infection and blockage of the device, yet little has been reported of the patterns and relationships among relevant catheter variables. Secondary data analysis was conducted from a sample in a randomised clinical trial, using data from the entire sample of 202 persons over 12 months' participation. Descriptive statistics were used to characterise the sample over time. Zero-inflated negative binomial models were employed for logistic regressions to evaluate predictor variables of the presence/absence and frequencies of catheter-related urinary tract infection and blockage. Catheter-related urinary tract infection was marginally associated with catheter blockage. Problems reported at least once per person in the 12 months were as follows: catheter-related urinary tract infection 57%, blockage 34%, accidental dislodgment 28%, sediment 87%, leakage (bypassing) 67%, bladder spasms 59%, kinks/twists 42% and catheter pain 49%. Regression analysis demonstrated that bladder spasms were significantly related to catheter-related urinary tract infection and sediment amount, and catheter leakages were marginally significantly and positively related to catheter-related urinary tract infection. Frequencies of higher levels of sediment and catheter leakage were significantly associated with higher levels of blockage, and being female was associated with fewer blockages. Persons who need help with eating (more disabled) were also more likely to have blockages. Catheter-related urinary tract infection and blockage appear to be related and both are associated with additional healthcare expenditures. More research is needed to better understand how to prevent adverse catheter outcomes and patterns of problems in

  7. Rational choice of peritoneal dialysis catheter.

    PubMed

    Dell'Aquila, Roberto; Chiaramonte, Stefano; Rodighiero, Maria Pia; Spanó, Emilia; Di Loreto, Pierluigi; Kohn, Catalina Ocampo; Cruz, Dinna; Polanco, Natalia; Kuang, Dingwei; Corradi, Valentina; De Cal, Massimo; Ronco, Claudio

    2007-06-01

    The peritoneal catheter should be a permanent and safe access to the peritoneal cavity. Catheter-related problems are often the cause of permanent transfer to hemodialysis (HD) in up to 20% of peritoneal dialysis (PD) patients; in some cases, these problems require a temporary period on HD. Advances in connectology have reduced the incidence of peritonitis, and so catheter-related complications during PD have become a major concern. In the last few years, novel techniques have emerged in the field of PD: new dialysis solutions, better connectology, and cyclers for automated PD. However, extracorporeal dialysis has continued to improve in terms of methods and patient survival, but PD has failed to do so. The main reason is that peritoneal access has remained problematical. The peritoneal catheter is the major obstacle to wide-spread use of PD. Overcoming catheter-related problems means giving a real chance to development of the peritoneal technique. Catheters should be as efficient, safe, and acceptable as possible. Since its introduction in the mid-1960s, the Tenckhoff catheter has not become obsolete: dozens of new models have been proposed, but none has significantly reduced the pre-dominance of the first catheter. No convincing prospective data demonstrate the superiority of any peritoneal catheter, and so it seems that factors other than choice of catheter are what affect survival and complication rates. Efforts to improve peritoneal catheter survival and complication rates should probably focus on factors other than the choice of catheter. The present article provides an overview of the characteristics of the best-known peritoneal catheters.

  8. Sodium citrate 4% versus heparin as a lock solution in hemodialysis patients with central venous catheters.

    PubMed

    Yon, Calantha K; Low, Chai L

    2013-01-15

    The effects of heparin versus sodium citrate 4% as a lock solution on catheter-related infections (CRIs), catheter patency, and hospitalizations in long-term hemodialysis patients with central venous catheters (CVCs) were compared. Data for patients receiving heparin lock solutions were collected from July 2008 to July 2009. Data on patients receiving sodium citrate 4% lock solution were collected from September 2009 through December 2010. Patients who were receiving the heparin lock solution who continued to have a CVC in September 2009 were transitioned from heparin to sodium citrate catheter 4% lock solution. New patients with CVCs placed after September 2009 received sodium citrate 4% without a period of using heparin lock solution. Pertinent information on patient medical history, bleeding or clotting events, infections, and hospitalization was collected. Data were collected retrospectively for the heparin group and prospectively for the sodium citrate group. Data were collected from 360 patient-months among 60 patients during the heparin treatment period and from 451 patient-months among 58 patients during the sodium citrate period. Thirty-three patients were common to both study groups. There were significantly more CRIs and CRIs per 1000 catheter-days in the heparin than the sodium citrate treatment group. Secondary outcomes of hospitalizations and catheter thrombosis were comparable. CRIs and thrombosis led to significantly more catheter exchanges or removals in the heparin group than the sodium citrate group. In patients with long-term hemodialysis catheters, a lock solution of sodium citrate 4% was associated with fewer CRIs and similar effectiveness when compared with heparin 5000 units/mL.

  9. Acute urinary retention: which catheter?

    PubMed Central

    Allardice, J. T.; Standfield, N. J.; Wyatt, A. P.

    1988-01-01

    There is no scientific data on which is the best method and catheter to use in acute urinary retention in males. We therefore compared the efficiency of a size 12 G latex rubber balloon catheter with a similar calibre but more expensive catheter made of polyvinyl-chloride (PVC). A total of 50 patients was studied and a 100% successful catheterisation rate was recorded at first attempt with both catheters, with no significant complications. The importance of the correct management of acute urinary retention, especially adequate analgesia, is stressed and it is concluded that either catheter is satisfactory. PMID:3207328

  10. Pressure-Guided Positioning of Bicaval Dual-Lumen Catheters for Venovenous Extracorporeal Gas Exchange

    DTIC Science & Technology

    2013-01-01

    inferior venae cavae , pumped through a respiratory mem- brane, and returned into the right atrium . The insertion of these cathe- ters is...sheath and advanced through the superior vena cava and the right atrium into the inferior vena cava . Correct position was confirmed via fluoroscopy...these catheters, blood is drained from the superior and inferior venae cavae through two dedicated ports and is pumped through a respiratory

  11. Echogenic Catheters and Embryo Transfer Standardization.

    PubMed

    Urbina, Maria Teresa; Benjamin, Isaac; Medina, Randolfo; Lerner, Jorge

    2015-05-01

    1.To describe the standardization process and protocols of the ET method at our center. 2.To compare the performance of non-echogenic catheters with echogenic catheters during ultrasound-guided ET. Retrospective analysis of 2630 ET performed at UNIFERTES during 1997-2014, to describe standardization process and to compare the percentage of difficult ET between echogenic and non-echogenic catheters. We tested 17 non-echogenic and three echogenic catheters. Many variables were associated with the ease of ET: informed patients, waiting time for the procedure, speculum use, clinical touch, uterine contractions, cervical mucus removal, presence of blood before or after the procedure, full bladder, ultrasound guidance, uterocervical angle, mock transfer, catheter type (soft or hard, echogenic or non-echogenic, with stylet or not), catheter loading technique, duration of embryo loading (time interval since the embryos were removed from the incubator for loading until the catheter is passed to the physician), transfer procedure (time interval from the catheter was handed to the physician until the embryos were discharged in the uterus), catheter tip placement, retained embryos, bed rest after ET, operator´s proficiency. The diversity of catheters used and the percentage of difficult transfers decrease as the use of echogenic catheters increases. This process is necessary to minimize variation, ensure high quality, safe and evidence-based practice, and improve outcomes. To standardize the ET method allowed a quicker and easier transfer. The use of echogenic catheters simplified ET procedures guided by abdominal ultrasound.

  12. Airway diffusing capacity of nitric oxide and steroid therapy in asthma.

    PubMed

    Shin, Hye-Won; Rose-Gottron, Christine M; Cooper, Dan M; Newcomb, Robert L; George, Steven C

    2004-01-01

    Exhaled nitric oxide (NO) concentration is a noninvasive index for monitoring lung inflammation in diseases such as asthma. The plateau concentration at constant flow is highly dependent on the exhalation flow rate and the use of corticosteroids and cannot distinguish airway and alveolar sources. In subjects with steroid-naive asthma (n = 8) or steroid-treated asthma (n = 12) and in healthy controls (n = 24), we measured flow-independent NO exchange parameters that partition exhaled NO into airway and alveolar regions and correlated these with symptoms and lung function. The mean (+/-SD) maximum airway flux (pl/s) and airway tissue concentration [parts/billion (ppb)] of NO were lower in steroid-treated asthmatic subjects compared with steroid-naive asthmatic subjects (1,195 +/- 836 pl/s and 143 +/- 66 ppb compared with 2,693 +/- 1,687 pl/s and 438 +/- 312 ppb, respectively). In contrast, the airway diffusing capacity for NO (pl.s-1.ppb-1) was elevated in both asthmatic groups compared with healthy controls, independent of steroid therapy (11.8 +/- 11.7, 8.71 +/- 5.74, and 3.13 +/- 1.57 pl.s-1.ppb-1 for steroid treated, steroid naive, and healthy controls, respectively). In addition, the airway diffusing capacity was inversely correlated with both forced expired volume in 1 s and forced vital capacity (%predicted), whereas the airway tissue concentration was positively correlated with forced vital capacity. Consistent with previously reported results from Silkoff et al. (Silkoff PE, Sylvester JT, Zamel N, and Permutt S, Am J Respir Crit Med 161: 1218-1228, 2000) that used an alternate technique, we conclude that the airway diffusing capacity for NO is elevated in asthma independent of steroid therapy and may reflect clinically relevant changes in airways.

  13. Fibrin Sheath Angioplasty: A Technique to Prevent Superior Vena Cava Stenosis Secondary to Dialysis Catheters

    PubMed Central

    Hacker, Robert I.; Garcia, Lorena De Marco; Chawla, Ankur; Panetta, Thomas F.

    2012-01-01

    Fibrin sheaths are a heterogeneous matrix of cells and debris that form around catheters and are a known cause of central venous stenosis and catheter failure. A total of 50 cases of central venous catheter fibrin sheath angioplasty (FSA) after catheter removal or exchange are presented. A retrospective review of an outpatient office database identified 70 eligible patients over a 19-month period. After informed consent was obtained, the dialysis catheter exiting the skin was clamped, amputated, and a wire was inserted. The catheter was then removed and a 9-French sheath was inserted into the superior vena cava, a venogram was performed. If a fibrin sheath was present, angioplasty was performed using an 8 × 4 or 10 × 4 balloon along the entire length of the fibrin sheath. A completion venogram was performed to document obliteration of the sheath. During the study, 50 patients were diagnosed with a fibrin sheath, and 43 had no pre-existing central venous stenosis. After FSA, 39 of the 43 patient's (91%) central systems remained patent without the need for subsequent interventions; 3 patients (7%) developed subclavian stenoses requiring repeat angioplasty and stenting; 1 patent (2.3%) developed an occlusion requiring a reintervention. Seven patients with prior central stenosis required multiple angioplasties; five required stenting of their central lesions. Every patient had follow-up fistulograms to document long-term patency. We propose that FSA is a prudent and safe procedure that may help reduce the risk of central venous stenosis from fibrin sheaths due to central venous catheters. PMID:23997555

  14. Central venous catheter-associated bloodstream infections in a pediatric intensive care unit: effect of the location of catheter insertion.

    PubMed

    Krishnaiah, Anil; Soothill, James; Wade, Angie; Mok, Quen Q; Ramnarayan, Padmanabhan

    2012-05-01

    To compare the rate of central venous catheter-associated bloodstream infections between pediatric intensive care unit admissions where central venous catheters were inserted within the same hospital (internal central venous catheters) and those where central venous catheters were inserted before transfer from other hospitals (external central venous catheters). Retrospective analysis of prospectively collected data. A tertiary care pediatric intensive care unit in London, UK. Consecutive pediatric intensive care unit admissions between May 2007 and March 2009. None. Catheter-associated bloodstream infections were identified using a widely accepted surveillance definition. The rate and time to occurrence of catheter-associated bloodstream infection were compared between internal and external nontunneled central venous catheters. A multilevel Cox-regression model was used to study the association between location of central venous catheter insertion and time to catheter-associated bloodstream infection. In total, 382 central venous catheters were studied (245 internal; 137 external) accounting for a total of 1,737 central venous catheter days. There was a higher catheter-associated bloodstream infection incidence density among external central venous catheters (23.1 [95% confidence interval 11.0-35.2] vs. 9.7 [95% confidence interval 3.9-15.5] per 1,000 catheter-days). Multivariable analyses demonstrated higher infection risk with external central venous catheters (hazard ratio 2.65 [95% confidence interval 1.18-5.96]) despite adjustment for confounding variables. The rate of catheter-associated bloodstream infections in the pediatric intensive care unit is significantly affected by external insertion of the central venous catheter. Future interventions to reduce nosocomial infections on pediatric intensive care units will need to be specifically targeted at this high-risk patient group.

  15. [The role of the uretral catheter in the development of catheter- related urinary tract infection].

    PubMed

    Vasilyev, A O; Govorov, A V; Shiryaev, A A; Pushkar, D Yu

    2017-12-01

    The most common source of nosocomial infection is the urinary tract, especially if they it is drained with a urethral catheter. Catheter-associated urinary tract infections account for at least 80% of all complicated urinary tract infections and are the most common type of hospital-acquired infection. Intestinal microflora plays the leading role in the pathogenesis of catheter-associated urinary tract infections, whereas the most important risk factor for their development is the long duration of urinary catheter drainage. In the case of short-term and intermittent catheterization, routine antibiotic prophylaxis is not required, but if a patient develops clinically significant infection, antibiotic therapy is required followed by definitive therapy based on culture. Urethral catheters coated with antimicrobial substances and anti-inflammatory agents can significantly reduce the adhesion and migration of bacteria, thereby reducing the incidence of urinary tract infections. Despite this, the incidence of catheter-associated infection remains high. We have reviewed recent literature related to catheter-associated urinary tract infections and the best means of preventing this condition.

  16. Initial Experience and Feasibility of the New Low-Profile Stingray Catheter as Part of the Antegrade Dissection and Re-Entry Revascularization Strategy for Coronary Chronic Total Occlusions

    PubMed Central

    Maeremans, Joren; Palmers, Pieter-Jan; Dens, Joseph

    2017-01-01

    Case series Patient: Male, 77 • Male, 57 • Male, 73 Final Diagnosis: Coronary chronic total occlusion Symptoms: Angina pectoris Medication: — Clinical Procedure: Percutaneous coronary intervention of coronary chronic total occlusions Specialty: Cardiology Objective: Unusual setting of medical care Background: During antegrade dissection re-entry (ADR) of chronic total occlusions (CTO), the first-generation Stingray catheter requires the use of large-bore guides (sheathless 7.5 Fr or 8 Fr), which increases the risk for access site-related complications and compromises radial approaches. Smaller guiding sizes necessitate long guidewires (e.g., 300 cm) or guidewire extensions for catheter advancement or removal. However, friction between guides and the Stingray catheter can result in unstable guidewire position or unintentional removal. Furthermore, failure to deliver the catheter at the distal re-entry zone is a common problem. To overcome issues of deliverability and reduce the need for pre-dilatations, with its inherent risk of creating subintimal hematomas, the Stingray low-profile (LP) balloon catheter was developed. Case Report: We describe 3 cases of successful application of the novel Stingray LP catheter during ADR. In all cases, 7 Fr guiding catheters were successfully used in combination with the device. The lower profile facilitated a good exchange and delivery of the device, without the need for balloon pre-dilatations in 2 cases. This resulted in a limited subintimal plane, enabling a smooth puncture into the true lumen. One case presented with extreme levels of calcification and tortuosity, resulting in a high degree of friction, despite the lower catheter profile. No in-hospital coronary or access site-related complications occurred. Conclusions: This case report illustrates the feasibility of the Stingray LP catheter for the treatment of CTOs via the ADR technique. The lower profile of the catheter potentially increases the deliverability

  17. [Urinary catheter biofilm infections].

    PubMed

    Holá, V; Růzicka, F

    2008-04-01

    Urinary tract infections, most of which are biofilm infections in catheterized patients, account for more than 40% of hospital infections. Bacterial colonization of the urinary tract and catheters causes not only infection but also other complications such as catheter blockage by bacterial encrustation, urolithiasis and pyelonephritis. About 50% of long-term catheterized patients face urinary flow obstruction due to catheter encrustation, but no measure is currently available to prevent it. Encrustation has been known either to result from metabolic dysfunction or to be of microbial origin, with urease positive bacterial species implicated most often. Infectious calculi account for about 15-20% of all cases of urolithiasis and are often associated with biofilm colonization of a long-term indwelling urinary catheter or urethral stent. The use of closed catheter systems is helpful in reducing such problems; nevertheless, such a system only delays the inevitable, with infections emerging a little later. Various coatings intended to prevent the bacterial adhesion to the surface of catheters and implants and thus also the emergence of biofilm infections, unfortunately, do not inhibit the microbial adhesion completely and permanently and the only reliable method for biofilm eradication remains the removal of the foreign body from the patient.

  18. [Rotational stability of angiography catheters].

    PubMed

    Schröder, J; Weber, M

    1992-10-01

    Rotatory stability is a parameter that reflects the ability of a catheter to transmit a rotation applied at the outer end to the catheter tip for the purpose of selective probing. A method for measuring the rotatory stability is described, and the results of rotatory stability measurements of 70 different commercially available catheters are reported. There is an almost linear correlation between the rotatory stability and the difference between the respective fourth power of the external and internal diameter or, approximately, to the fourth power of the external diameter for catheters without wire reinforcement. With the same cross-sectional dimensions, the rotatory stability of teflon, polyethylene, and nylon catheters has an approximate ratio of 1:2:4. Wire reinforcement increases rotatory stability by an average factor of about 3. For catheters of calibers 5 F and 6 F, a correlation between the rotatory stability and the weight of the reinforcing wire mesh is apparent.

  19. Automated airway evaluation system for multi-slice computed tomography using airway lumen diameter, airway wall thickness and broncho-arterial ratio

    NASA Astrophysics Data System (ADS)

    Odry, Benjamin L.; Kiraly, Atilla P.; Novak, Carol L.; Naidich, David P.; Lerallut, Jean-Francois

    2006-03-01

    Pulmonary diseases such as bronchiectasis, asthma, and emphysema are characterized by abnormalities in airway dimensions. Multi-slice computed tomography (MSCT) has become one of the primary means to depict these abnormalities, as the availability of high-resolution near-isotropic data makes it possible to evaluate airways at oblique angles to the scanner plane. However, currently, clinical evaluation of airways is typically limited to subjective visual inspection only: systematic evaluation of the airways to take advantage of high-resolution data has not proved practical without automation. We present an automated method to quantitatively evaluate airway lumen diameter, wall thickness and broncho-arterial ratios. In addition, our method provides 3D visualization of these values, graphically illustrating the location and extent of disease. Our algorithm begins by automatic airway segmentation to extract paths to the distal airways, and to create a map of airway diameters. Normally, airway diameters decrease as paths progress distally; failure to taper indicates abnormal dilatation. Our approach monitors airway lumen diameters along each airway path in order to detect abnormal profiles, allowing even subtle degrees of pathologic dilatation to be identified. Our method also systematically computes the broncho-arterial ratio at every terminal branch of the tree model, as a ratio above 1 indicates potentially abnormal bronchial dilatation. Finally, the airway wall thickness is computed at corresponding locations. These measurements are used to highlight abnormal branches for closer inspection, and can be summed to compute a quantitative global score for the entire airway tree, allowing reproducible longitudinal assessment of disease severity. Preliminary tests on patients diagnosed with bronchiectasis demonstrated rapid identification of lack of tapering, which also was confirmed by corresponding demonstration of elevated broncho-arterial ratios.

  20. Azithromycin ameliorates airway remodeling via inhibiting airway epithelium apoptosis.

    PubMed

    Liu, Yuanqi; Pu, Yue; Li, Diandian; Zhou, Liming; Wan, Lihong

    2017-02-01

    Azithromycin can benefit treating allergic airway inflammation and remodeling. In the present study, we hypothesized that azithromycin alleviated airway epithelium injury through inhibiting airway epithelium apoptosis via down regulation of caspase-3 and Bax/Bcl2 ratio in vivo and in vitro. Ovalbumin induced rat asthma model and TGF-β1-induced BEAS-2B cell apoptosis model were established, respectively. In vivo experiments, airway epithelium was stained with hematoxylin and eosin (HE) and periodic acid-Schiff (PAS) to histologically evaluate the airway inflammation and remodeling. Airway epithelium apoptotic index (AI) was further analyzed by terminal deoxynucleotidyl transferase-mediated dUTP nick end labeling (TUNEL), while expression of apoptosis related gene (Bax, Bcl2, Caspase-3) in lungs were measured by qRT-PCR and western blotting, respectively. In vitro experiments, apoptosis were evaluated by Flow cytometry (FCM) and TUNEL. Above apoptosis related gene were also measured by qRT-PCR and western blotting. Compared with the OVA group, azithromycin significantly reduced the inflammation score, peribronchial smooth muscle layer thickness, epithelial thickening and goblet cell metaplasia (P<0.05), and effectively suppressed AI of airway epithelium (P<0.05). Moreover, the increasing mRNA and protein expressions of Caspase-3 and Bax/Bcl-2 ratio in lung tissue were all significantly decreased in azithromycin-treated rats (P<0.05). In vitro, azithromycin significantly suppressed TGF-β1-induced BEAS-2B cells apoptosis (P<0.05) and reversed TGF-β1 elevated Caspase-3 mRNA level and Bax/Bcl-2 ratio (P<0.05). Azithromycin is an attractive treatment option for reducing airway epithelial cell apoptosis by improving the imbalance of Bax/Bcl-2 ratio and inhibiting Caspase-3 level in airway epithelium. Copyright © 2016 Elsevier Inc. All rights reserved.

  1. Bladder Morphology Using 2 Different Catheter Designs

    ClinicalTrials.gov

    2017-04-10

    Urologic Injuries; Urologic Diseases; Bladder Infection; Urinary Tract Infections; Mucosal Inflammation; Mucosal Infection; Bladder Injury; Catheter-Related Infections; Catheter Complications; Catheter; Infection (Indwelling Catheter); Pelvic Floor Disorders; Urinary Incontinence

  2. Difficult airway management practice patterns among anesthesiologists practicing in the United States: have we made any progress?

    PubMed

    Ezri, Tiberiu; Szmuk, Peter; Warters, R David; Katz, Jeffrey; Hagberg, Carin A

    2003-09-01

    To determine the extent instruction and practice in the use of airway devices and techniques varies among anesthesiologists practicing in the United States. Survey questionnaire. University medical center. Questionnaires were completed by American-trained anesthesiologists who attended the 1999 American Society of Anesthesiologists (ASA) Annual Meeting. Data collected included demographics, education, skills with airway devices/techniques, management of clinical difficult airway scenarios, and the use of the ASA Difficult Airway Algorithm. 1) DEMOGRAPHICS: 452 questionnaires were correctly completed; 62% attending anesthesiologists, 70% <50 years, 81% males, 44% from academic institutions, 63% >10 years of practice, 81% night duty, 77% board certified. 2) Education: 71% had at least one educational modality: difficult airway rotation, workshops, conferences, books, and simulators. 3) Skills: Miller blade 61%, Bullard laryngoscope 32%, LMA 86%, Combitube 43%, bougie 43%, exchangers 47%, cuffed oropharyngeal airway (COPA) 34%, retrograde 41%, transtracheal needle jet ventilation 34%, cricothyrotomy 21%, fiberoptics 59%, and blind nasal intubation 78%. The average reported use of special airway devices/techniques was 47.5%. 4) Management choices: failed intubation/ventilation: LMA (81%) and for all other situations: fiberoptic intubation. Use of ASA Difficult Airway Algorithm in clinical practice (86%). Fiberoptic intubation and the LMA are most popular in management of the difficult airway.

  3. Embryo Transfer Catheters: Softer is Easier.

    PubMed

    Ruhlmann, Claudio; Gnocchi, Diego C; Cattaneo, Antonio R; Molina, Lucas G; Rivadeneira, Luciano Ruiz; Tessari, Lautaro; Martínez, Alejandro G

    2015-11-01

    This study aimed to compare the use of semi-rigid and flexible catheters in terms of pregnancy rate and level of difficulty of the embryo transfer (ET) procedure. Seven hundred and thirty-nine consecutive follicular aspirations for IVF or ICSI performed in our private fertility clinic within a 30-month period were randomly divided into two groups. Patients were allocated to either of the groups at the time of follicular retrieval with the aid of a random number generator according to the catheter used in ET: Group 1 (n = 370) - Frydman Classic Catheter 4.5 catheters; and Group 2 (n = 369) - Frydman Ultrasoft 4.5 catheters. Only patients offered ET in the randomized cycle were included (Group 1 = 363 and Group 2 = 340). Patients did not change groups after catheter allocation. Statistical analysis was carried out using an unpaired t-test or a chi square test as appropriate. Differences with P<0.05 were considered. A statistically significant difference in favor of the use of the Ultrasoft catheter was evident for parameters use of a tenaculum (19.8% vs. 5.9%) or a hysterometer (5.0% vs. 1.2%), presence of blood during post-ET inspection of the catheter (9.9% vs. 3.8%), and implantation rate (13.0% vs. 16.4%). Clinical pregnancy and delivery rates were comparable in both groups. Our results suggest that a softer catheter may help with difficult ETs. Softer catheters, as also reported by other authors, resulted in better implantation rates.

  4. Emergency coronary angioplasty with stenting using Cordis® diagnostic coronary catheters when there is difficulty in engaging guide catheters and bench evaluation of diagnostic and guide catheters.

    PubMed

    Arokiaraj, Mark Christopher

    2018-02-01

    Difficulty in engaging with guide catheters is not uncommon in acute emergencies. We aimed to evaluate the use of Cordis ® INFINITI diagnostic catheters to perform angioplasty in patients in whom the coronaries cannot be engaged using standard guide catheters. In 34 cases of acute coronary syndrome, when difficulty in engagement with two standard guide catheters was encountered with reasonable manipulations, angioplasty was performed using diagnostic catheters. In total, 40 stents were placed by this technique. Pushability and trackability, distal tip flexion and three-point bending tests were performed to evaluate the performance of the guide and diagnostic catheters. Angioplasty was performed easily in a setting where it would have been very difficult to perform. Coronary dissection occurred in one patient, treated by a stent. The stent and dilatation balloons were easily passed through the diagnostic catheters. Pressure tracings were clearly preserved with certain stent delivery systems, and at angioplasty, although there was slightly reduced opacification of the respective artery, the coronary anatomy was sufficiently visualized to perform angioplasty. No periprocedural target lesion complications were seen in any cases. Pushability and trackability tests showed good force transmission along a tortuous path with diagnostic catheters, and balanced force-displacement curves from three-point bending tests and distal tip softness tests. Angioplasty with stenting can be performed safely through 6F Cordis ® infiniti diagnostic catheters when difficulty in engaging guide catheters is encountered. Copyright © 2018 Sociedade Portuguesa de Cardiologia. Publicado por Elsevier España, S.L.U. All rights reserved.

  5. Protective effects of valproic acid against airway hyperresponsiveness and airway remodeling in a mouse model of allergic airways disease.

    PubMed

    Royce, Simon G; Dang, William; Ververis, Katherine; De Sampayo, Nishika; El-Osta, Assam; Tang, Mimi L K; Karagiannis, Tom C

    2011-12-01

    Airway remodeling and airway hyperresponsiveness are major aspects of asthma pathology that are not targeted optimally by existing anti-inflammatory drugs. Histone deacetylase inhibitors have a wide range of effects that may potentially abrogate aspects of remodeling. One such histone deacetylase inhibitor is valproic acid (2-propylvaleric acid). Valproic acid is used clinically as an anti-epileptic drug and is a potent inhibitor of class I histone deacetylases but also inhibits class II histone deacetylases. We used valproic acid as a molecular model of histone deacetylase inhibition in vivo in chronic allergic airways disease mice with airway remodeling and airway hyperresponsiveness. Wild-type Balb/c mice with allergic airways disease were treated with valproic acid or vehicle control. Airway inflammation was assessed by bronchoalveolar lavage fluid cell counts and examination of lung tissue sections. Remodeling was assessed by morphometric analysis of histochemically stained slides and lung function was assessed by invasive plethysmography measurement of airway resistance. Valproic acid treatment did not affect inflammation parameters; however, valproic acid treatment resulted in reduced epithelial thickness as compared to vehicle treated mice (p < 0.01), reduced subepithelial collagen deposition (p < 0.05) and attenuated airway hyperresponsiveness (p < 0.05 and p < 0.01 for the two highest doses of methacholine, respectively). These findings show that treatment with valproic acid can reduce structural airway remodeling changes and hyperresponsiveness, providing further evidence for the potential use of histone deacetylase inhibitors for the treatment of asthma.

  6. Experimental evidence of age-related adaptive changes in human acinar airways

    PubMed Central

    Quirk, James D.; Sukstanskii, Alexander L.; Woods, Jason C.; Lutey, Barbara A.; Conradi, Mark S.; Gierada, David S.; Yusen, Roger D.; Castro, Mario

    2015-01-01

    The progressive decline of lung function with aging is associated with changes in lung structure at all levels, from conducting airways to acinar airways (alveolar ducts and sacs). While information on conducting airways is becoming available from computed tomography, in vivo information on the acinar airways is not conventionally available, even though acini occupy 95% of lung volume and serve as major gas exchange units of the lung. The objectives of this study are to measure morphometric parameters of lung acinar airways in living adult humans over a broad range of ages by using an innovative MRI-based technique, in vivo lung morphometry with hyperpolarized 3He gas, and to determine the influence of age-related differences in acinar airway morphometry on lung function. Pulmonary function tests and MRI with hyperpolarized 3He gas were performed on 24 healthy nonsmokers aged 19-71 years. The most significant age-related difference across this population was a 27% loss of alveolar depth, h, leading to a 46% increased acinar airway lumen radius, hence, decreased resistance to acinar air transport. Importantly, the data show a negative correlation between h and the pulmonary function measures forced expiratory volume in 1 s and forced vital capacity. In vivo lung morphometry provides unique information on age-related changes in lung microstructure and their influence on lung function. We hypothesize that the observed reduction of alveolar depth in subjects with advanced aging represents a remodeling process that might be a compensatory mechanism, without which the pulmonary functional decline due to other biological factors with advancing age would be significantly larger. PMID:26542518

  7. Airway stents

    PubMed Central

    Keyes, Colleen

    2018-01-01

    Stents and tubes to maintain the patency of the airways are commonly used for malignant obstruction and are occasionally employed in benign disease. Malignant airway obstruction usually results from direct involvement of bronchogenic carcinoma, or by extension of carcinomas occurring in the esophagus or the thyroid. External compression from lymph nodes or metastatic disease from other organs can also cause central airway obstruction. Most malignant airway lesions are surgically inoperable due to advanced disease stage and require multimodality palliation, including stent placement. As with any other medical device, stents have significantly evolved over the last 50 years and deserve an in-depth understanding of their true capabilities and complications. Not every silicone stent is created equal and the same holds for metallic stents. Herein, we present an overview of the topic as well as some of the more practical and controversial issues surrounding airway stents. We also try to dispel the myths surrounding stent removal and their supposed use only in central airways. At the end, we come to the long-held conclusion that stents should not be used as first line treatment of choice, but after ruling out the possibility of curative surgical resection or repair. PMID:29707506

  8. Catheter-related bloodstream infection with removal of catheter in pediatric oncology patients: a 10-year experience in Taiwan.

    PubMed

    Chen, Shih-Hsiang; Yang, Chao-Ping; Jaing, Tang-Her; Lai, Jin-Yao; Hung, Iou-Jih

    2012-04-01

    Long-term central venous catheter (CVC) implantation has become more affordable in Taiwan since 1995. Surgical removal of the catheter may be the essential treatment for catheter-related bloodstream infections (CRBSI). The aim of this study was to evaluate the clinical features and microbial isolates in pediatric cancer patients with removal of CVC for CRBSI. The records of positive blood culture from hospitalized pediatric oncology patients between 1995 and 2004 were reviewed. One hundred and forty-three patients implanted with a long-term CVC were further identified. Seventeen catheters in 16 patients developed catheter-related bacteremia that needed catheter removal. The rate of catheter removal was 11.9%. The median device life was 7.7 months. Six catheters were removed within 3 months of insertion. Nine of the 17 catheters were removed from patient younger than 2 years. Eight infections occurred during severe neutropenia, and 6 patients had refractory or relapsed underlying disease. The cultural isolates were Gram-negative bacilli in 7, Gram-positive in 5, fungi in 5, and atypical mycobacterium in 1. The frequency of catheter removal for infection control was significantly higher in the first 5 years (1994-1999) compared to the last 5 years (2000-2004) (30.9 vs. 4.0%, p = 2.3 × 10(-4)). Factors such as microbiological isolates, age of infection, the status of malignancy, and neutropenia are related to catheter outcome. The reduction in patients with positive cultures needing removal of the catheters can be related to improved nursing care and more aggressive antibiotic therapy.

  9. Coronary angioplasty with second generation Monorail catheters.

    PubMed

    Pande, A K; Meier, B; Urban, P; Villavicencio, R; de la Serna, F; Moles, V

    1991-07-01

    The Monorail system (Schneider) consists of a balloon catheter in which the guidewire passes through the balloon itself, exits the catheter proximal to the balloon, and runs alongside its small shaft (3 French) through the length of the guiding catheter. It offers distinct advantages over conventional systems of coronary angioplasty. It facilitates contrast injections and permits rapid balloon exchanges. This system was used for coronary angioplasty in 273 unselected consecutive patients (age 59 +/- 10, mean 35 to 73 years). There were 216 patients (84%) undergoing single-vessel and 57 patients (16%) with multi-vessel coronary angioplasty. A total of 335 coronary stenoses were dilated, which included 35 total occlusions. The size of balloon used ranged from 2.0 to 4.25 mm (3.0 +/- 0.5 mm) and the severity of stenosis was 85 +/- 11%. Technical success was defined as a residual stenosis of less than 50% as determined angiographically. Clinical success was defined as technical success, and absence of a major inhospital complication defined as absence of myocardial infarction, lack of need for coronary arterial bypass surgery, and survival. The Monorail system was technically successful in 294/300 stenotic lesions (98%). It was clinically successful for 281 lesions (94%). Of the 35 total occlusions, technical success was obtained in 25 (71%). The residual stenosis of successful cases was 26 +/- 21%. The Monorail system was also successful in 5 patients with stenosis of more than 90% in whom conventional systems failed. The complications included acute occlusion causing acute myocardial infarction in 13 cases (5%), emergency coronary arterial bypass surgery in 1 patient (0.4%), and death in 4 patients (1.5%).(ABSTRACT TRUNCATED AT 250 WORDS)

  10. Catheter ablation of atrial fibrillation using remote magnetic catheter navigation: a case-control study.

    PubMed

    Arya, Arash; Zaker-Shahrak, Ruzbeh; Sommer, Phillip; Bollmann, Andreas; Wetzel, Ulrike; Gaspar, Thomas; Richter, Sergio; Husser, Daniela; Piorkowski, Christopher; Hindricks, Gerhard

    2011-01-01

    To compare the acute and the 6 month outcome of catheter ablation of atrial fibrillation (AF) using irrigated tip magnetic catheter and remote magnetic cathter navigation (RMN) with manual catheter navigation (MCN) in patients with paroxysmal and persistent AF. In this retrospective analysis 356 patients (235 male, mean age: 57.9 ± 10.9 years) with AF (70.5%, paroxysmal) who underwent catheter ablation between August 2007 and May 2008 using either RMN (n = 70, 46 male, mean age: 57.9 ± 10.1 years, 50% paroxysmal) or MCN (n = 286, 189 male, mean age: 58.0 ± 13.9 years, 75.5% paroxysmal) were included. All patients completed an intensive follow-up strategy. Complete pulmonary vein isolation was achieved in 87.6 and 99.6% of patients in RMN and MCN groups, respectively (P < 0.05). The procedure, fluoroscopy, and radiofrequency application times were 223 ± 44 vs. 166 ± 52 min (P < 0.0001), 13.7 ± 7.8 vs. 34.5 ± 15.1 min (P < 0.0001), and 75.4 ± 20.9 vs. 53.2 ± 21.4 min (P < 0.0001) in RMN and MCN groups, respectively. Seven (10.0%) and 28 (9.8%) patients in RMN and MCN groups received antiarrhythmic medications during the follow-up (P = 0.96). All the patients completed the 6 month follow-up. Freedom from AF at 6 months was achieved in 57.8 and 66.4% of the patients in RMN and MCN groups, respectively (P = 0.196). In patients without previous AF catheter ablation procedure the freedom from AF at 6 months were 68.2 and 60.5% in the MCN and RMN groups, respectively (P = 0.36). Catheter ablation using irrigated tip magnetic catheter and RMN is an effective and safe method for catheter ablation of AF. Compared to manual catheter navigation, the procedure and radiofrequency application times were longer and fluoroscopy time was shorter in the RMN group compared with the MCN group.

  11. Local small airway epithelial injury induces global smooth muscle contraction and airway constriction.

    PubMed

    Zhou, Jian; Alvarez-Elizondo, Martha B; Botvinick, Elliot; George, Steven C

    2012-02-01

    Small airway epithelial cells form a continuous sheet lining the conducting airways, which serves many functions including a physical barrier to protect the underlying tissue. In asthma, injury to epithelial cells can occur during bronchoconstriction, which may exacerbate airway hyperreactivity. To investigate the role of epithelial cell rupture in airway constriction, laser ablation was used to precisely rupture individual airway epithelial cells of small airways (<300-μm diameter) in rat lung slices (∼250-μm thick). Laser ablation of single epithelial cells using a femtosecond laser reproducibly induced airway contraction to ∼70% of the original cross-sectional area within several seconds, and the contraction lasted for up to 40 s. The airway constriction could be mimicked by mechanical rupture of a single epithelial cell using a sharp glass micropipette but not with a blunt glass pipette. These results suggest that soluble mediators released from the wounded epithelial cell induce global airway contraction. To confirm this hypothesis, the lysate of primary human small airway epithelial cells stimulated a similar airway contraction. Laser ablation of single epithelial cells triggered a single instantaneous Ca(2+) wave in the epithelium, and multiple Ca(2+) waves in smooth muscle cells, which were delayed by several seconds. Removal of extracellular Ca(2+) or decreasing intracellular Ca(2+) both blocked laser-induced airway contraction. We conclude that local epithelial cell rupture induces rapid and global airway constriction through release of soluble mediators and subsequent Ca(2+)-dependent smooth muscle shortening.

  12. Is it feasible to diagnose catheter-related candidemia without catheter withdrawal?

    PubMed

    Fernández-Cruz, Ana; Martín-Rabadán, Pablo; Suárez-Salas, Marisol; Rojas-Wettig, Loreto; Pérez, María Jesús; Guinea, Jesús; Guembe, María; Peláez, Teresa; Sánchez-Carrillo, Carlos; Bouza, Emilio

    2014-07-01

    Many bloodstream infections (BSI) in patients with central venous catheters (CVC) are not catheter-related (CR). Assessment of catheter involvement without catheter withdrawal has not been studied in candidemia. We assessed the value of conservative techniques to evaluate catheters as the origin of candidemia in patients with CVC in a prospective cohort study (superficial Gram stain and culture, Kite technique (Gram stain and culture of the first 1 cm blood drawn from the CVC), proportion of positive blood cultures (PPBCs), differential time to positivity (DTP), and minimal time to positivity (MTP)). All catheters were cultured at withdrawal. From June 2008 to January 2012, 22 cases fulfilled the inclusion criteria. CR-candidemia (CRC) was confirmed in 10. Validity values for predicting CRC were: superficial Gram stain (S, 30%; Sp, 81.83%; PPV, 60%; NPV, 56.3%; Ac, 57.1%), superficial cultures (S, 40%; Sp, 75%; PPV, 57.1%; NPV, 60%; Ac, 59.1%), Kite Gram stain (S, 33.3%; Sp, 66.7%; PPV, 50%; NPV, 50%; Ac, 50%), Kite culture (S, 80%; Sp, 66.7%; PPV, 66.7%; NPV, 80%; Ac, 72.7%), PPBC (S, 50%; Sp, 41.7%; PPV, 41.7%; NPV, 50.0%; Ac, 45.5%), DTP (S, 100%; Sp, 33.3%; PPV, 55.6%; NPV, 100%; Ac, 63.6%), and MTTP (S, 70%; Sp, 58.3%; PPV, 58.3%; NPV, 70%; Ac, 63.6%). While combinations of two tests improved sensitivity and NPV, more than two tests did not improve validity values. Classic tests to assess CR-BSI caused by bacteria cannot be reliably used to diagnose CRC. Combinations of tests could be useful, but more and larger studies are required. © The Author 2014. Published by Oxford University Press on behalf of The International Society for Human and Animal Mycology. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  13. Continuous Positive Airway Pressure Strategies with Bubble Nasal Continuous Positive Airway Pressure: Not All Bubbling Is the Same: The Seattle Positive Airway Pressure System.

    PubMed

    Welty, Stephen E

    2016-12-01

    Premature neonates are predisposed to complications, including bronchopulmonary dysplasia (BPD). BPD is associated with long-term pulmonary and neurodevelopmental consequences. Noninvasive respiratory support with nasal continuous positive airway pressure (CPAP) has been recommended strongly by the American Academy of Pediatrics. However, CPAP implementation has shown at least a 50% failure rate. Enhancing nasal CPAP effectiveness may decrease the need for mechanical ventilation and reduce the incidence of BPD. Bubble nasal CPAP is better than nasal CPAP using mechanical devices and the bubbling provides air exchange in distal respiratory units. The Seattle PAP system reduces parameters that assess work of breathing. Copyright © 2016 Elsevier Inc. All rights reserved.

  14. Atopic asthmatic immune phenotypes associated with airway microbiota and airway obstruction.

    PubMed

    Turturice, Benjamin A; McGee, Halvor S; Oliver, Brian; Baraket, Melissa; Nguyen, Brian T; Ascoli, Christian; Ranjan, Ravi; Rani, Asha; Perkins, David L; Finn, Patricia W

    2017-01-01

    Differences in asthma severity may be related to inflammation in the airways. The lower airway microbiota has been associated with clinical features such as airway obstruction, symptom control, and response to corticosteroids. To assess the relationship between local airway inflammation, severity of disease, and the lower airway microbiota in atopic asthmatics. A cohort of young adult, atopic asthmatics with intermittent or mild/moderate persistent symptoms (n = 13) were assessed via bronchoscopy, lavage, and spirometry. These individuals were compared to age matched non-asthmatic controls (n = 6) and to themselves after six weeks of treatment with fluticasone propionate (FP). Inflammation of the airways was assessed via a cytokine and chemokine panel. Lower airway microbiota composition was determined by metagenomic shotgun sequencing. Unsupervised clustering of cytokines and chemokines prior to treatment with FP identified two asthmatic phenotypes (AP), termed AP1 and AP2, with distinct bronchoalveolar lavage inflammatory profiles. AP2 was associated with more obstruction, compared to AP1. After treatment with FP reduced MIP-1β and TNF-α and increased IL-2 was observed. A module of highly correlated cytokines that include MIP-1β and TNF-α was identified that negatively correlated with pulmonary function. Independently, IL-2 was positively correlated with pulmonary function. The airway microbiome composition correlated with asthmatic phenotypes. AP2, prior to FP treatment, was enriched with Streptococcus pneumoniae. Unique associations between IL-2 or the cytokine module and the microbiota composition of the airways were observed in asthmatics subjects prior to treatment but not after or in controls. The underlying inflammation in atopic asthma is related to the composition of microbiota and is associated with severity of airway obstruction. Treatment with inhaled corticosteroids was associated with changes in the airway inflammatory response to microbiota.

  15. Evaluation of urinary catheters coated with sustained-release varnish of chlorhexidine in mitigating biofilm formation on urinary catheters in dogs.

    PubMed

    Segev, G; Bankirer, T; Steinberg, D; Duvdevani, M; Shapur, N K; Friedman, M; Lavy, E

    2013-01-01

    Biofilm formation occurs commonly on urinary catheters. To assess the efficacy of urinary catheters coated with sustained-release varnish of chlorhexidine in decreasing catheter-associated biofilm formation in dogs. Thirty client-owned dogs. Prospective study. Thirteen dogs were catheterized with urinary catheters coated with sustained-release varnish of chlorhexidine (study group), and 13 dogs were catheterized with an untreated urinary catheter (control group). Presence and intensity of biofilm formation on the urinary catheters were assessed and compared between the groups by evaluating colony-forming units (CFU) of biofilm bacteria, and semiquantitatively, using confocal laser scanning microscopy and electron microscopy. None of the dogs experienced adverse effects associated with the presence of the urinary catheters. Median CFU count of biofilm bacteria at all portions of the urinary catheter was significantly (P < .001) lower in the study compared with the control group. The degree of biofilm formation on the urinary catheters, as evaluated by confocal laser scanning microscopy and electron microscopy, was significantly lower in the study compared with the control group. Electron microscopy examination identified crystals on some of the urinary catheters. The proportion of catheters on which crystals were observed was significantly lower on the distal part of the urinary catheter in the study group compared with the control group (16.7% versus 66.7%, respectively; P = .04). Chlorhexidine sustained-release varnish-coated urinary catheters effectively decrease urinary catheter-associated biofilm formation in dogs. Copyright © 2012 by the American College of Veterinary Internal Medicine.

  16. Toxicity testing of urinary catheters.

    PubMed

    Talja, M; Andersson, L C; Ruutu, M; Alfthan, O

    1985-10-01

    The tissue toxicity of 23 urinary catheter batches (6 latex and 2 non-latex brands) was tested in vitro and in vivo. In vitro, a human T-cell leukemia line (JM) was cultured in the presence of different concentrations of eluates made from the catheters. The cytotoxicity of the eluates was assessed from their ability to inhibit DNA synthesis measured by incorporation of 3H-thymidine. In vivo, two methods were used. Strips of catheters were implanted into the rabbit dorsal muscle and pieces of catheters were implanted into the rat peritoneal cavity. After four days, the foreign body reaction, type of inflammation and necrosis were quantified macroscopically and by light microscopy. The results of the in vitro cytotoxicity test were correlated with those of in vivo methods. The rat peritoneal implantation test correlated better with the cell culture test (P less than 0.01) than with the rabbit muscle implantation test (P less than 0.05). Based on the clinical experience of urethral stricture complications caused by urinary catheters, catheters yielding eluate which at 30% dilution inhibited 50% DNA synthesis were regarded as toxic. According to this, the rabbit muscle implantation test was not reliable in testing the tissue toxicity of urinary catheters, while the cell culture test was quantitative and seemed to correlate with both the rat peritoneal implantation test and with the clinical complications observed.

  17. Degrees of reality: airway anatomy of high-fidelity human patient simulators and airway trainers.

    PubMed

    Schebesta, Karl; Hüpfl, Michael; Rössler, Bernhard; Ringl, Helmut; Müller, Michael P; Kimberger, Oliver

    2012-06-01

    Human patient simulators and airway training manikins are widely used to train airway management skills to medical professionals. Furthermore, these patient simulators are employed as standardized "patients" to evaluate airway devices. However, little is known about how realistic these patient simulators and airway-training manikins really are. This trial aimed to evaluate the upper airway anatomy of four high-fidelity patient simulators and two airway trainers in comparison with actual patients by means of radiographic measurements. The volume of the pharyngeal airspace was the primary outcome parameter. Computed tomography scans of 20 adult trauma patients without head or neck injuries were compared with computed tomography scans of four high-fidelity patient simulators and two airway trainers. By using 14 predefined distances, two cross-sectional areas and three volume parameters of the upper airway, the manikins' similarity to a human patient was assessed. The pharyngeal airspace of all manikins differed significantly from the patients' pharyngeal airspace. The HPS Human Patient Simulator (METI®, Sarasota, FL) was the most realistic high-fidelity patient simulator (6/19 [32%] of all parameters were within the 95% CI of human airway measurements). The airway anatomy of four high-fidelity patient simulators and two airway trainers does not reflect the upper airway anatomy of actual patients. This finding may impact airway training and confound comparative airway device studies.

  18. Local small airway epithelial injury induces global smooth muscle contraction and airway constriction

    PubMed Central

    Zhou, Jian; Alvarez-Elizondo, Martha B.; Botvinick, Elliot

    2012-01-01

    Small airway epithelial cells form a continuous sheet lining the conducting airways, which serves many functions including a physical barrier to protect the underlying tissue. In asthma, injury to epithelial cells can occur during bronchoconstriction, which may exacerbate airway hyperreactivity. To investigate the role of epithelial cell rupture in airway constriction, laser ablation was used to precisely rupture individual airway epithelial cells of small airways (<300-μm diameter) in rat lung slices (∼250-μm thick). Laser ablation of single epithelial cells using a femtosecond laser reproducibly induced airway contraction to ∼70% of the original cross-sectional area within several seconds, and the contraction lasted for up to 40 s. The airway constriction could be mimicked by mechanical rupture of a single epithelial cell using a sharp glass micropipette but not with a blunt glass pipette. These results suggest that soluble mediators released from the wounded epithelial cell induce global airway contraction. To confirm this hypothesis, the lysate of primary human small airway epithelial cells stimulated a similar airway contraction. Laser ablation of single epithelial cells triggered a single instantaneous Ca2+ wave in the epithelium, and multiple Ca2+ waves in smooth muscle cells, which were delayed by several seconds. Removal of extracellular Ca2+ or decreasing intracellular Ca2+ both blocked laser-induced airway contraction. We conclude that local epithelial cell rupture induces rapid and global airway constriction through release of soluble mediators and subsequent Ca2+-dependent smooth muscle shortening. PMID:22114176

  19. Successful retrieval of an entrapped Rotablator burr using 5 Fr guiding catheter.

    PubMed

    Kimura, Masayoshi; Shiraishi, Jun; Kohno, Yoshio

    2011-10-01

    Although burr entrapment is a rare complication of the Rotablator, it is extremely difficult to retrieve a fixedly entrapped burr without surgical procedure. An 84-year-old male with effort angina had heavily calcified coronary trees as well as severe stenosis in the mid LCx, and moderate stenosis in the proximal LCx, and in the LMT. We planned to perform rotational atherectomy in the LCx lesions. Using 7 Fr Q-curve guiding catheter and Rotawire floppy, we began to ablate using 1.5-mm burr at 200,000 rpm. Because the burr could not pass the proximal stenosis, we exchanged the wire for Rotawire extrasupport and the burr for 1.25-mm burr, and restarted the ablation at 220,000 rpm. Although the burr could manage to pass the proximal stenosis, it had become trapped in the mid LCx lesion. Simple pull on the Rotablator, rotation of the burr, and crossing the Conquest (Confianza) wire could not retrieve it. Thus, we cut off the drive shaft and sheath of the Rotablator, inserted 5 Fr 120-cm straight guiding catheter (Heartrail ST01; Terumo) through the remaining Rotablator system, pushed the catheter tip to the lesion around the burr as well as simultaneously pulled the Rotablator, and finally could retrieve it. Then we implanted stents in the LCx and in the LMT without difficulty. The 5 Fr straight guiding catheter might be useful for retrieving an entrapped burr (1.25-mm burr). Copyright © 2011 Wiley-Liss, Inc.

  20. Parasympathetic Control of Airway Submucosal Glands: Central Reflexes and the Airway Intrinsic Nervous System

    PubMed Central

    Wine, Jeffrey J.

    2007-01-01

    Airway submucosal glands produce the mucus that lines the upper airways to protect them against insults. This review summarizes evidence for two forms of gland secretion, and hypothesizes that each is mediated by different but partially overlapping neural pathways. Airway innate defense comprises low level gland secretion, mucociliary clearance and surveillance by airway-resident phagocytes to keep the airways sterile in spite of nearly continuous inhalation of low levels of pathogens. Gland secretion serving innate defense is hypothesized to be under the control of intrinsic (peripheral) airway neurons and local reflexes, and these may depend disproportionately on non-cholinergic mechanisms, with most secretion being produced by VIP and tachykinins. In the genetic disease cystic fibrosis, airway glands no longer secrete in response to VIP alone and fail to show the synergy between VIP, tachykinins and ACh that is observed in normal glands. The consequent crippling of the submucosal gland contribution to innate defense may be one reason that cystic fibrosis airways are infected by mucus-resident bacteria and fungi that are routinely cleared from normal airways. By contrast, the acute (emergency) airway defense reflex is centrally mediated by vagal pathways, is primarily cholinergic, and stimulates copious volumes of gland mucus in response to acute, intense challenges to the airways, such as those produced by very vigorous exercise or aspiration of foreign material. In cystic fibrosis, the acute airway defense reflex can still stimulate the glands to secrete large amounts of mucus, although its properties are altered. Importantly, treatments that recruit components of the acute reflex, such as inhalation of hypertonic saline, are beneficial in treating cystic fibrosis airway disease. The situation for recipients of lung transplants is the reverse; transplanted airways retain the airway intrinsic nervous system but lose centrally mediated reflexes. The consequences

  1. Catheter-associated urinary tract infection.

    PubMed

    Tambyah, Paul A; Oon, Jolene

    2012-08-01

    Catheter-associated urinary tract infection (CAUTI) is the commonest nosocomial infection worldwide. Here we review the recent advances in the prevention of CAUTI. After more than 30 years, new guidelines were issued in 2008-2011 by the Infectious Diseases Society of America, Society for Healthcare Epidemiology of America, Healthcare Infection Control Practices Advisory Committee and European Association of Urology. These guidelines addressed novel technologies such as silver alloy or antimicrobial coatings on catheters, hydrophilic catheters, urethral stents, use of sealed catheter-tube junctions and antiinfective bladder irrigation. In addition, multiple trials have been published recently on the reduction of inappropriate urinary tract catheterization. Numerous strategies have been developed to reduce the incidence of CAUTI but few have proven effective. Reducing the inappropriate use of catheters and development of novel technologies targeted against these increasingly multidrug-resistant pathogens may be useful in the prevention of CAUTI in our vulnerable patients.

  2. Insertion of tunneled hemodialysis catheters without fluoroscopy.

    PubMed

    Motta Elias, Rosilene; da Silva Makida, Sonia Cristina; Abensur, Hugo; Martins Castro, Manuel Carlos; Affonso Moysés, Rosa Maria; Pereira, Benedito Jorge; Bueno de Oliveira, Rodrigo; Luders, Cláudio; Romão, João Egidio

    2010-01-01

    The tunneled cuffed catheter (TCC) is used as a bridge access for hemodialysis. Few prospective studies have been designed to evaluate conversion from non-tunneled to TCC without the use of fluoroscopy when performed by nephrologists. We performed an observational prospective cohort in incident patients receiving hemodialysis through a non-tunneled right jugular vein catheter. 130 procedures were performed in 122 patients (51+/-18 years). The success rate was 100%. There was a total of 26,546 catheter days. Ninety-one of the 130 catheters were removed during the study period. Life table analysis revealed primary patency rates of 92%, 82%, and 68% at 30, 60, and 120 days, respectively. Infection requiring catheter removal occurred at a frequency of 0.09 per 100 catheter days. Catheter malfunction requiring intervention occurred at a rate of 0.03 per 100 catheter days. Hypertension and duration of existing non-tunneled catheter of less than 2 weeks were independently associated with better TCC survival. The conversion from non-tunneled to TCC performed by nephrologists and without fluoroscopy may be safe by using the internal right jugular vein. The ideal time to do this procedure is within less than 2 weeks of existing non-tunneled catheter.

  3. Effect of Heat Moisture Exchanger on Aerosol Drug Delivery and Airway Resistance in Simulated Ventilator-Dependent Adults Using Jet and Mesh Nebulizers.

    PubMed

    Ari, Arzu; Dang, Truong; Al Enazi, Fahad H; Alqahtani, Mohammed M; Alkhathami, Abdulrahman; Qoutah, Rowaida; Almamary, Ahmad S; Fink, James B

    2018-02-01

    Placement of a heat moisture exchanger (HME) between aerosol generator and patient has been associated with greatly reduced drug delivery. The purpose of this study was to evaluate the effect of filtered and nonfiltered HMEs placed between nebulizer and patient on aerosol deposition and airway resistance (Raw) in simulated ventilator-dependent adults. An in vitro lung model was developed to simulate a mechanically ventilated adult (Vt 500 mL, RR 15/min, and PEEP 5 cmH 2 O, using two inspiratory flow rates 40 and 50 L/min) using an intubated adult manikin with an endotracheal tube (8 mmID). The bronchi of the manikin were connected to a Y-adapter through a collecting filter (Respirgard II) attached to a test lung through a heated humidifier (37°C producing 100% relative humidity) to simulate exhaled humidity. For treatment conditions, a nonfiltered HME (ThermoFlo™ 6070; ARC Medical) and filtered HMEs (ThermoFlo™ Filter; ARC Medical and PALL Ultipor; Pall Medical) were placed between the ventilator circuit at the endotracheal tube and allowed to acclimate to the exhaled heat and humidity for 30 minutes before aerosol administration. Airway resistance (cmH 2 O/L/s) was taken at 0, 10, 20, and 30 minutes after HME placement and after each of four aerosol treatments. Albuterol sulfate (2.5 mg/3 mL) was administered with jet (Misty Max 10; Airlife) and mesh (Aerogen Solo; Aerogen) nebulizers positioned in the inspiratory limb proximal to the Y-adapter. Control consisted of nebulization with no HME. Drug was eluted from filter at the end of the trachea and measured using spectrophotometry (276 nm). Greater than 60% of the control dose was delivered through the ThermoFlo. No significant difference was found between the first four treatments given by the jet (p = 0.825) and the mesh (p = 0.753) nebulizers. There is a small increase in Raw between pre- and post-four treatments with the jet (p = 0.001) and mesh (p = 0.015) nebulizers. Aerosol

  4. Ventilation heterogeneity is a major determinant of airway hyperresponsiveness in asthma, independent of airway inflammation

    PubMed Central

    Downie, Sue R; Salome, Cheryl M; Verbanck, Sylvia; Thompson, Bruce; Berend, Norbert; King, Gregory G

    2007-01-01

    Background Airway hyperresponsiveness is the ability of airways to narrow excessively in response to inhaled stimuli and is a key feature of asthma. Airway inflammation and ventilation heterogeneity have been separately shown to be associated with airway hyperresponsiveness. A study was undertaken to establish whether ventilation heterogeneity is associated with airway hyperresponsiveness independently of airway inflammation in subjects with asthma and to determine the effect of inhaled corticosteroids on this relationship. Methods Airway inflammation was measured in 40 subjects with asthma by exhaled nitric oxide, ventilation heterogeneity by multiple breath nitrogen washout and airway hyperresponsiveness by methacholine challenge. In 18 of these subjects with uncontrolled symptoms, measurements were repeated after 3 months of treatment with inhaled beclomethasone dipropionate. Results At baseline, airway hyperresponsiveness was independently predicted by airway inflammation (partial r2 = 0.20, p<0.001) and ventilation heterogeneity (partial r2 = 0.39, p<0.001). Inhaled corticosteroid treatment decreased airway inflammation (p = 0.002), ventilation heterogeneity (p = 0.009) and airway hyperresponsiveness (p<0.001). After treatment, ventilation heterogeneity was the sole predictor of airway hyperresponsiveness (r2 = 0.64, p<0.001). Conclusions Baseline ventilation heterogeneity is a strong predictor of airway hyperresponsiveness, independent of airway inflammation in subjects with asthma. Its persistent relationship with airway hyperresponsiveness following anti‐inflammatory treatment suggests that it is an important independent determinant of airway hyperresponsiveness. Normalisation of ventilation heterogeneity is therefore a potential goal of treatment that may lead to improved long‐term outcomes. PMID:17311839

  5. Debris buster is a Drosophila scavenger receptor essential for airway physiology.

    PubMed

    Wingen, Almut; Carrera, Pilar; Ekaterini Psathaki, Olympia; Voelzmann, André; Paululat, Achim; Hoch, Michael

    2017-10-01

    Scavenger receptors class B (SR-B) are multifunctional transmembrane proteins, which in vertebrates participate in lipid transport, pathogen clearance, lysosomal delivery and intracellular sorting. Drosophila has 14 SR-B members whose functions are still largely unknown. Here, we reveal a novel role for the SR-B family member Debris buster (Dsb) in Drosophila airway physiology. Larvae lacking dsb show yeast avoidance behavior, hypoxia, and severe growth defects associated with impaired elongation and integrity along the airways. Furthermore, in dsb mutant embryos, the barrier function of the posterior spiracles, which are critical for gas exchange, is not properly established and liquid clearance is locally impaired at the spiracular lumen. We found that Dsb is specifically expressed in a group of distal epithelial cells of the posterior spiracle organ and not throughout the entire airways. Furthermore, tissue-specific knockdown and rescue experiments demonstrate that Dsb function in the airways is only required in the posterior spiracles. Dsb localizes in intracellular vesicles, and a subset of these associate with lysosomes. However, we found that depletion of proteins involved in vesicular transport to the apical membrane, but not in lysosomal function, causes dsb-like airway elongation defects. We propose a model in which Dsb sorts components of the apical extracellular matrix which are essential for airway physiology. Since SR-B LIMP2-deficient mice show reduced expression of several apical plasma membrane proteins, sorting of proteins to the apical membrane is likely an evolutionary conserved function of Dsb and LIMP2. Our data provide insights into a spatially confined function of the SR-B Dsb in intracellular trafficking critical for the physiology of the whole tubular airway network. Copyright © 2017 Elsevier Inc. All rights reserved.

  6. Bacterial contamination of epidural catheters: microbiological examination of 502 epidural catheters used for postoperative analgesia.

    PubMed

    Steffen, Peter; Seeling, Wulf; Essig, Andreas; Stiepan, Erika; Rockemann, Michael Georg

    2004-03-01

    To investigate the frequency of bacterial colonization of epidural catheters used for postoperative pain treatment longer than 24 hours in abdominal, thoracic, or trauma surgery patients. Retrospective study. Intermediate care facility and general ward of a university hospital. 502 patients who received epidural catheters after abdominal, thoracic, or vascular surgery at our institution from January 1996 to December 2000. Placement of an epidural catheter, which was used for postoperative pain treatment, for more than 24 hours. The puncture site dressing included saturation each day with povidone-iodine. Microbiologic monitoring of epidural catheter tips and daily examination of puncture sites with regard to signs of inflammation took place. Four times daily patients were examined to check adequacy of pain treatment and neurologic deficits. Catheter tip cultures were positive in 29 patients (5.8%). Staphylococcus epidermidis was isolated in 22 cases (76%). No case of spinal epidural abscess was observed within 6 months after epidural catheterization. The average catheterization time was 5 days (quartile range: 4 to 6 days). Meticulous management ensures a relatively low level of bacterial contamination in epidural catheters applied for postoperative pain treatment greater than 5 days. Contamination rarely leads to spinal epidural infection.

  7. Percutaneous transaortic occlusion of patent ductus arteriosus using a new versatile angiographic and delivery catheter.

    PubMed

    Lorber, A; Gazit, A Z; Khoury, A; Schwartz, Y; Freudental, F

    2003-01-01

    We evaluated the usefulness of patent ductus arteriosus (PDA) occlusion using a new catheter that combines good angiographic properties, easy manipulation across the duct, documentation of aortic and pulmonary artery pressure, and coil delivery for percutaneous transaortic ductal occlusion. Thirty patients (13 females and 17 males) who met the clinical and echocardiographic criteria for the percutaneous closure of PDA were catheterized. The patients selected for this study had a small to moderate PDA with a conal or tubular shape, adequate aortic ampula, and normal or mildly elevated pulmonary artery pressure. The median age was 4.8 years (range, 10 months-20 years). Patients were catheterized by the transaortic approach using the new angiographic and coil delivery catheter specially designed for this procedure. A PDA was closed in every case. A single DuctOcclud pfm coil was delivered in 28 patients, and 2 patients had NitOcclud pfm coils for ductal occlusion. The screening time was measured and found to be 50% less than the measured screening time using other catheters in our laboratory. Only one catheter and one guidewire were used per procedure, with no need for exchange wires or the establishment of an arteriovenous loop. The procedure time was also reduced by 50%. A minimal residual shunt, demonstrated by color-flow Doppler mapping, was present in 2 patients. The new combined angiographic and coil delivery catheter is most suitable for transaortic PDA coil occlusion, significantly decreasing the procedure and screening time.

  8. Large eccentric laser angioplasty catheter

    NASA Astrophysics Data System (ADS)

    Taylor, Kevin D.; Reiser, Christopher

    1997-05-01

    In response to recent demand for increased debulking of large diameter coronary vascular segments, a large eccentric catheter for excimer laser coronary angioplasty has been developed. The outer tip diameter is 2.0 mm and incorporates approximately 300 fibers of 50 micron diameter in a monorail- type percutaneous catheter. The basic function of the device is to ablate a coronary atherosclerotic lesion with 308 nm excimer laser pulses, while passing the tip of the catheter through the lesion. By employing multiple passes through the lesion, rotating the catheter 90 degrees after each pass, we expect to create luminal diameters close to 3 mm with this device. Design characteristics, in-vitro testing, and initial clinical experience is presented.

  9. Minilaparotomy salvage of malfunctioning catheters in peritoneal dialysis.

    PubMed

    Li, Jian-Ri; Cheng, Chi-Hung; Chiu, Kun-Yuan; Cheng, Chen-Li; Yang, Chi-Rei; Ho, Hao-Chung; Ko, Jiunn-Liang; Ou, Yen-Chuan

    2013-01-01

    Catheter malfunction is a common and significant complication during peritoneal dialysis (PD). We developed a minilaparotomy procedure to rescue malfunctioning catheters and to prevent recurrence of malfunction. From 2006 to 2011, 11 patients receiving PD had a malfunctioning catheter. In all patients, a 2-cm incision, 5 cm caudally to the previous peritoneal entry site was used to correct the malfunctioning catheter, with concomitant fixation of the catheter to the peritoneum. Catheter tip migration occurred in 7 patients, omental wrapping in 3, and blood clot obstruction in 1. The mean onset time to catheter malfunction was 197.5 days (range: 4 - 1270 days), and the mean operating time was 41 minutes (range: 35 - 56 minutes). There was no recurrence of catheter malfunction and no surgery-related peritonitis. Our minilaparotomy procedure is safe and feasible for the salvage of malfunctioning PD catheters.

  10. The effect of peripherally inserted central catheter (PICC) valve technology on catheter occlusion rates--the 'ELeCTRiC' study.

    PubMed

    Johnston, Andrew J; Streater, Carmel T; Noorani, Remy; Crofts, Joanne L; Del Mundo, Aldwin B; Parker, Richard A

    2012-01-01

    Peripherally Inserted Central Catheters (PICCs) are increasingly being used to provide short to medium-term central venous access. The current study was designed to test the hypothesis that PICC valve technology does not influence PICC occlusion rates. Intensive care unit (ICU) patients who required a PICC were randomized to one of three types of dual lumen PICC (open ended non-valved, Groshong valve, PASV valve). PICC occlusions were recorded and managed with a protocol that used urokinase. A total of 102 patients were recruited to the study. The overall risk of occlusion per catheter was 35% (95% CI 26% to 44%). The overall rate of occlusion was 76 occlusions per 1000 catheter days (95% CI 61 to 95). Presence or type of valve did not significantly influence this rate (open-ended non-valved PICC 38% of catheters, 79 occlusions per 1000 catheter days; Groshong 38% of catheters, 60 occlusions per 1000 catheter days; PASV 27% of catheters, 99 occlusions per 1000 catheter days). The dose of urokinase required to treat PICC occlusions did not significantly differ between PICC types. Valved PICCs do not appear to influence PICC occlusion rates.

  11. Parasympathetic control of airway submucosal glands: central reflexes and the airway intrinsic nervous system.

    PubMed

    Wine, Jeffrey J

    2007-04-30

    Airway submucosal glands produce the mucus that lines the upper airways to protect them against insults. This review summarizes evidence for two forms of gland secretion, and hypothesizes that each is mediated by different but partially overlapping neural pathways. Airway innate defense comprises low level gland secretion, mucociliary clearance and surveillance by airway-resident phagocytes to keep the airways sterile in spite of nearly continuous inhalation of low levels of pathogens. Gland secretion serving innate defense is hypothesized to be under the control of intrinsic (peripheral) airway neurons and local reflexes, and these may depend disproportionately on non-cholinergic mechanisms, with most secretion being produced by VIP and tachykinins. In the genetic disease cystic fibrosis, airway glands no longer secrete in response to VIP alone and fail to show the synergy between VIP, tachykinins and ACh that is observed in normal glands. The consequent crippling of the submucosal gland contribution to innate defense may be one reason that cystic fibrosis airways are infected by mucus-resident bacteria and fungi that are routinely cleared from normal airways. By contrast, the acute (emergency) airway defense reflex is centrally mediated by vagal pathways, is primarily cholinergic, and stimulates copious volumes of gland mucus in response to acute, intense challenges to the airways, such as those produced by very vigorous exercise or aspiration of foreign material. In cystic fibrosis, the acute airway defense reflex can still stimulate the glands to secrete large amounts of mucus, although its properties are altered. Importantly, treatments that recruit components of the acute reflex, such as inhalation of hypertonic saline, are beneficial in treating cystic fibrosis airway disease. The situation for recipients of lung transplants is the reverse; transplanted airways retain the airway intrinsic nervous system but lose centrally mediated reflexes. The consequences

  12. 21 CFR 876.5130 - Urological catheter and accessories.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... device that is inserted through the urethra and used to pass fluids to or from the urinary tract. This..., coude catheters, balloon retention type catheters, straight catheters, upper urinary tract catheters...

  13. 21 CFR 870.1210 - Continuous flush catheter.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1210 Continuous flush catheter. (a) Identification. A continuous flush catheter is an attachment to a catheter-transducer system...

  14. 21 CFR 870.1210 - Continuous flush catheter.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1210 Continuous flush catheter. (a) Identification. A continuous flush catheter is an attachment to a catheter-transducer system...

  15. 21 CFR 870.1210 - Continuous flush catheter.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1210 Continuous flush catheter. (a) Identification. A continuous flush catheter is an attachment to a catheter-transducer system...

  16. Anti-fouling strategies for central venous catheters

    PubMed Central

    Albadawi, Hassan; Patel, Nikasha; Khademhosseini, Ali; Zhang, Yu Shrike; Naidu, Sailendra; Knuttinen, Grace; Oklu, Rahmi

    2017-01-01

    Central venous catheters (CVCs) are ubiquitous in the healthcare industry and carry two common complications, catheter related infections and occlusion, particularly by thrombus. Catheter-related bloodstream infections (CRBSI) are an important cause of nosocomial infections that increase patient morbidity, mortality, and hospital cost. Innovative design strategies for intravenous catheters can help reduce these preventable infections. Antimicrobial coatings can play a major role in preventing disease. These coatings can be divided into two major categories: drug eluting and non-drug eluting. Much of these catheter designs are targeted at preventing the formation of microbial biofilms that make treatment of CRBSI nearly impossible without removal of the intravenous device. Exciting developments in catheter impregnation with antibiotics as well as nanoscale surface design promise innovative changes in the way that physicians manage intravenous catheters. Occlusion of a catheter renders the catheter unusable and is often treated by tissue plasminogen activator administration or replacement of the line. Prevention of this complication requires a thorough understanding of the mechanisms of platelet aggregation, signaling and cross-linking. This article will look at the advances in biomaterial design specifically drug eluting, non-drug eluting, lubricious coatings and micropatterning as well as some of the characteristics of each as they relate to CVCs. PMID:29399528

  17. Anti-fouling strategies for central venous catheters.

    PubMed

    Wallace, Alex; Albadawi, Hassan; Patel, Nikasha; Khademhosseini, Ali; Zhang, Yu Shrike; Naidu, Sailendra; Knuttinen, Grace; Oklu, Rahmi

    2017-12-01

    Central venous catheters (CVCs) are ubiquitous in the healthcare industry and carry two common complications, catheter related infections and occlusion, particularly by thrombus. Catheter-related bloodstream infections (CRBSI) are an important cause of nosocomial infections that increase patient morbidity, mortality, and hospital cost. Innovative design strategies for intravenous catheters can help reduce these preventable infections. Antimicrobial coatings can play a major role in preventing disease. These coatings can be divided into two major categories: drug eluting and non-drug eluting. Much of these catheter designs are targeted at preventing the formation of microbial biofilms that make treatment of CRBSI nearly impossible without removal of the intravenous device. Exciting developments in catheter impregnation with antibiotics as well as nanoscale surface design promise innovative changes in the way that physicians manage intravenous catheters. Occlusion of a catheter renders the catheter unusable and is often treated by tissue plasminogen activator administration or replacement of the line. Prevention of this complication requires a thorough understanding of the mechanisms of platelet aggregation, signaling and cross-linking. This article will look at the advances in biomaterial design specifically drug eluting, non-drug eluting, lubricious coatings and micropatterning as well as some of the characteristics of each as they relate to CVCs.

  18. Outcomes after peritoneal dialysis catheter placement.

    PubMed

    Carpenter, Jennifer L; Fallon, Sara C; Swartz, Sarah J; Minifee, Paul K; Cass, Darrell L; Nuchtern, Jed G; Pimpalwar, Ashwin P; Brandt, Mary L

    2016-05-01

    The purpose of this study was to review surgical outcomes after elective placement of peritoneal dialysis (PD) catheters in children with end-stage renal disease. Children with PD catheters placed between February 2002 and July 2014 were retrospectively reviewed. Outcomes were catheter life, late (>30days post-op) complications (catheter malfunction, catheter malposition, infection), and re-operation rates. Comparison groups included laparoscopic versus open placement, age<2, and weight<10kg. Univariate and multivariate analysis were performed. One hundred sixteen patients had 173 catheters placed (122 open, 51 laparoscopic) with an average patient age of 9.7±6.3years. Mean catheter life was similar in the laparoscopic and open groups (581±539days versus 574±487days, p=0.938). The late complication rate was higher for open procedures (57% versus 37%, p=0.013). Children age<2 or weight<10kg had higher re-operation rates (64% versus 42%, p=0.014 and 73% versus 40%, p=0.001, respectively). Adjusted for age and weight, open technique remained a risk factor for late complications (OR 2.44, 95% CI 1.20-4.95) but not re-operation. Laparoscopic placement appears to reduce the rate of late complications in children who require PD dialysis catheters. Children <2years age or <10kg remain at risk for complications regardless of technique. Copyright © 2016 Elsevier Inc. All rights reserved.

  19. Advanced Imaging Catheter: Final Project Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Krulevitch, P; Colston, B; DaSilva, L

    2001-07-20

    Minimally invasive surgery (MIS) is an approach whereby procedures conventionally performed with large and potentially traumatic incisions are replaced by several tiny incisions through which specialized instruments are inserted. Early MIS, often called laparoscopic surgery, used video cameras and laparoscopes to visualize and control the medical devices, which were typically cutting or stapling tools. More recently, catheter-based procedures have become a fast growing sector of all surgeries. In these procedures, small incisions are made into one of the main arteries (e.g. femoral artery in the thigh), and a long thin hollow tube is inserted and positioned near the target area.more » The key advantage of this technique is that recovery time can be reduced from months to a matter of days. In the United States, over 700,000 catheter procedures are performed annually representing a market of over $350 million. Further growth in this area will require significant improvements in the current catheter technology. In order to effectively navigate a catheter through the tortuous vessels of the body, two capabilities must exist: imaging and positioning. In most cases, catheter procedures rely on radiography for visualization and manual manipulation for positioning of the device. Radiography provides two-dimensional, global images of the vasculature and cannot be used continuously due to radiation exposure to both the patient and physician. Intravascular ultrasound devices are available for continuous local imaging at the catheter tip, but these devices cannot be used simultaneously with therapeutic devices. Catheters are highly compliant devices, and manipulating the catheter is similar to pushing on a string. Often, a guide wire is used to help position the catheter, but this procedure has its own set of problems. Three characteristics are used to describe catheter maneuverability: (1) pushability -- the amount of linear displacement of the distal end (inside body

  20. 21 CFR 870.1200 - Diagnostic intravascular catheter.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... intracardiac pressures, to sample blood, and to introduce substances into the heart and vessels. Included in this generic device are right-heart catheters, left-heart catheters, and angiographic catheters, among...

  1. 21 CFR 870.1200 - Diagnostic intravascular catheter.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... intracardiac pressures, to sample blood, and to introduce substances into the heart and vessels. Included in this generic device are right-heart catheters, left-heart catheters, and angiographic catheters, among...

  2. 21 CFR 870.1200 - Diagnostic intravascular catheter.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... intracardiac pressures, to sample blood, and to introduce substances into the heart and vessels. Included in this generic device are right-heart catheters, left-heart catheters, and angiographic catheters, among...

  3. 21 CFR 870.1200 - Diagnostic intravascular catheter.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... intracardiac pressures, to sample blood, and to introduce substances into the heart and vessels. Included in this generic device are right-heart catheters, left-heart catheters, and angiographic catheters, among...

  4. 21 CFR 870.1200 - Diagnostic intravascular catheter.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... intracardiac pressures, to sample blood, and to introduce substances into the heart and vessels. Included in this generic device are right-heart catheters, left-heart catheters, and angiographic catheters, among...

  5. [Incidence of phlebitis due to peripherally inserted venous catheters: impact of a catheter management protocol].

    PubMed

    Ferrete-Morales, C; Vázquez-Pérez, M A; Sánchez-Berna, M; Gilabert-Cerro, I; Corzo-Delgado, J E; Pineda-Vergara, J A; Vergara-López, S; Gómez-Mateos, J

    2010-01-01

    To assess the impact on the incidence of PPIVC by implementing a catheter management protocol and to determine risk factors for PPIVC development in hospitalized patients. A total of 3978 episodes of venous catheterization were prospectively included from September 2002 to December 2007. A catheter management protocol was implemented during this period of time. The incidence and variables associated to the occurrence of PPIVC were determined. The incidence of PPIVC from 2002 to 2007 was 4.8%, 4.3%, 3.6%, 2.5%, 1.3% and 1.8% (p<0.001). Perfusion of amiodarone [adjusted OR (AOR) 25.97; 95% CI=7.29-92.55, p=0.0001] and cefotaxime (AOR 2.90; 95% CI=1.29-6.52, p=0.01) and the shift when the catheters were placed (AOR for morning vs. night shift 0.60; 95% CI=0.35-1.02, p=0.063) were independently associated to the development of PPIVC. A history of phlebitis was the only factor independently associated to phlebitis due to peripherally inserted central venous catheters (AOR 3.24; CI at 95% CI= 1.05-9.98, p=0.04). A catheter management protocol decreases the incidence of PPIVC in hospitalized patients. The risk of PPIVC increases for peripherally inserted central venous catheters when the patients have a history of phlebitis and for peripheral venous catheters when amiodarone or cefotaxime are infused. Catheterization of peripheral veins performed during morning shifts is associated with a lower incidence of PPIVC when compared with night shift catheterizations.

  6. Host-microbe interactions in distal airways: relevance to chronic airway diseases.

    PubMed

    Martin, Clémence; Burgel, Pierre-Régis; Lepage, Patricia; Andréjak, Claire; de Blic, Jacques; Bourdin, Arnaud; Brouard, Jacques; Chanez, Pascal; Dalphin, Jean-Charles; Deslée, Gaetan; Deschildre, Antoine; Gosset, Philippe; Touqui, Lhousseine; Dusser, Daniel

    2015-03-01

    This article is the summary of a workshop, which took place in November 2013, on the roles of microorganisms in chronic respiratory diseases. Until recently, it was assumed that lower airways were sterile in healthy individuals. However, it has long been acknowledged that microorganisms could be identified in distal airway secretions from patients with various respiratory diseases, including cystic fibrosis (CF) and non-CF bronchiectasis, chronic obstructive pulmonary disease, asthma and other chronic airway diseases (e.g. post-transplantation bronchiolitis obliterans). These microorganisms were sometimes considered as infectious agents that triggered host immune responses and contributed to disease onset and/or progression; alternatively, microorganisms were often considered as colonisers, which were considered unlikely to play roles in disease pathophysiology. These concepts were developed at a time when the identification of microorganisms relied on culture-based methods. Importantly, the majority of microorganisms cannot be cultured using conventional methods, and the use of novel culture-independent methods that rely on the identification of microorganism genomes has revealed that healthy distal airways display a complex flora called the airway microbiota. The present article reviews some aspects of current literature on host-microbe (mostly bacteria and viruses) interactions in healthy and diseased airways, with a special focus on distal airways. Copyright ©ERS 2015.

  7. The New Perilaryngeal Airway (CobraPLA™)1 Is as Efficient as the Laryngeal Mask Airway (LMA™)2, But Provides Better Airway Sealing Pressures

    PubMed Central

    Akça, Ozan; Wadhwa, Anupama; Sengupta, Papiya; Durrani, Jaleel; Hanni, Keith; Wenke, Mary; Yücel, Yüksel; Lenhardt, Rainer; Doufas, Anthony G.; Sessler, Daniel I.

    2006-01-01

    The Laryngeal Mask Airway (LMA) is a frequently-used efficient airway device, yet it sometimes seals poorly, thus reducing the efficacy of positive-pressure ventilation. The Perilaryngeal Airway (CobraPLA) is a novel airway device with a larger pharyngeal cuff (when inflated). We tested the hypothesis that the CobraPLA was superior to LMA with regard to insertion time and airway sealing pressure and comparable to LMA in airway adequacy and recovery characteristics. After midazolam and fentanyl, 81 ASA I-II outpatients having elective surgery were randomized to receive an LMA or CobraPLA. Anesthesia was induced with propofol (2.5 mg/kg, IV), and the airway inserted. We measured 1) insertion time; 2) adequacy of the airway (no leak at 15-cm-H2O peak pressure or tidal volume of 5 ml/kg); 3) airway sealing pressure; 4) number of repositioning attempts; and 5) sealing quality (no leak at tidal volume of 8 ml/kg). At the end of surgery, gastric insufflation, postoperative sore throat, dysphonia, and dysphagia were evaluated. Data were compared with unpaired t-tests, chi-square tests, or Fisher’s Exact tests; P<0.05 was significant. Patient characteristics, insertion times, airway adequacy, number of repositioning attempts, and recovery were similar in each group. Airway sealing pressure was significantly greater with CobraPLA (23±6 cm H2O) than LMA (18±5 cm H2O, P<0.001). The CobraPLA has insertion characteristics similar to LMA, but better airway sealing capabilities. PMID:15281543

  8. Airway surface mycosis in chronic TH2-associated airway disease.

    PubMed

    Porter, Paul C; Lim, Dae Jun; Maskatia, Zahida Khan; Mak, Garbo; Tsai, Chu-Lin; Citardi, Martin J; Fakhri, Samer; Shaw, Joanne L; Fothergil, Annette; Kheradmand, Farrah; Corry, David B; Luong, Amber

    2014-08-01

    Environmental fungi have been linked to TH2 cell-related airway inflammation and the TH2-associated chronic airway diseases asthma, chronic rhinosinusitis (CRS) with nasal polyps (CRSwNP), and allergic fungal rhinosinusitis (AFRS), but whether these organisms participate directly or indirectly in disease pathology remains unknown. To determine the frequency of fungus isolation and fungus-specific immunity in patients with TH2-associated and non-TH2-associated airway disease. Sinus lavage fluid and blood were collected from sinus surgery patients (n = 118) including patients with CRSwNP, patients with CRS without nasal polyps, patients with AFRS, and non-CRS/nonasthmatic control patients. Asthma status was determined from medical history. Sinus lavage fluids were cultured and directly examined for evidence of viable fungi. PBMCs were restimulated with fungal antigens in an enzyme-linked immunocell spot assay to determine total memory fungus-specific IL-4-secreting cells. These data were compared with fungus-specific IgE levels measured from plasma by ELISA. Filamentous fungi were significantly more commonly cultured in patients with TH2-associated airway disease (asthma, CRSwNP, or AFRS: n = 68) than in control patients with non-TH2-associated disease (n = 31): 74% vs 16%, respectively (P < .001). Both fungus-specific IL-4 enzyme-linked immunocell spot (n = 48) and specific IgE (n = 70) data correlated with TH2-associated diseases (sensitivity 73% and specificity 100% vs 50% and 77%, respectively). The frequent isolation of fungi growing directly within the airways accompanied by specific immunity to these organisms only in patients with TH2-associated chronic airway diseases suggests that fungi participate directly in the pathogenesis of these conditions. Efforts to eradicate airway fungi from the airways should be considered in selected patients. Copyright © 2014 American Academy of Allergy, Asthma & Immunology. Published by Mosby, Inc. All rights reserved.

  9. Cystic Fibrosis Transmembrane Conductance Regulator in Sarcoplasmic Reticulum of Airway Smooth Muscle. Implications for Airway Contractility

    PubMed Central

    Cook, Daniel P.; Rector, Michael V.; Bouzek, Drake C.; Michalski, Andrew S.; Gansemer, Nicholas D.; Reznikov, Leah R.; Li, Xiaopeng; Stroik, Mallory R.; Ostedgaard, Lynda S.; Abou Alaiwa, Mahmoud H.; Thompson, Michael A.; Prakash, Y. S.; Krishnan, Ramaswamy; Meyerholz, David K.; Seow, Chun Y.

    2016-01-01

    Rationale: An asthma-like airway phenotype has been described in people with cystic fibrosis (CF). Whether these findings are directly caused by loss of CF transmembrane conductance regulator (CFTR) function or secondary to chronic airway infection and/or inflammation has been difficult to determine. Objectives: Airway contractility is primarily determined by airway smooth muscle. We tested the hypothesis that CFTR is expressed in airway smooth muscle and directly affects airway smooth muscle contractility. Methods: Newborn pigs, both wild type and with CF (before the onset of airway infection and inflammation), were used in this study. High-resolution immunofluorescence was used to identify the subcellular localization of CFTR in airway smooth muscle. Airway smooth muscle function was determined with tissue myography, intracellular calcium measurements, and regulatory myosin light chain phosphorylation status. Precision-cut lung slices were used to investigate the therapeutic potential of CFTR modulation on airway reactivity. Measurements and Main Results: We found that CFTR localizes to the sarcoplasmic reticulum compartment of airway smooth muscle and regulates airway smooth muscle tone. Loss of CFTR function led to delayed calcium reuptake following cholinergic stimulation and increased myosin light chain phosphorylation. CFTR potentiation with ivacaftor decreased airway reactivity in precision-cut lung slices following cholinergic stimulation. Conclusions: Loss of CFTR alters porcine airway smooth muscle function and may contribute to the airflow obstruction phenotype observed in human CF. Airway smooth muscle CFTR may represent a therapeutic target in CF and other diseases of airway narrowing. PMID:26488271

  10. Prevention of catheter-related blood stream infection.

    PubMed

    Byrnes, Matthew C; Coopersmith, Craig M

    2007-08-01

    Catheter-related blood stream infections are a morbid complication of central venous catheters. This review will highlight a comprehensive approach demonstrated to prevent catheter-related blood stream infections. Elements of prevention important to inserting a central venous catheter include proper hand hygiene, use of full barrier precautions, appropriate skin preparation with 2% chlorhexidine, and using the subclavian vein as the preferred anatomic site. Rigorous attention needs to be given to dressing care, and there should be daily assessment of the need for central venous catheters, with prompt removal as soon as is practicable. Healthcare workers should be educated routinely on methods to prevent catheter-related blood stream infections. If rates remain higher than benchmark levels despite proper bedside practice, antiseptic or antibiotic-impregnated catheters can also prevent infections effectively. A recent program utilizing these practices in 103 ICUs in Michigan resulted in a 66% decrease in infection rates. There is increasing recognition that a comprehensive strategy to prevent catheter-related blood stream infections can prevent most infections, if not all. This suggests that thousands of infections can potentially be averted if the simple practices outlined herein are followed.

  11. Prevention of catheter-associated urinary tract infection

    PubMed Central

    Trautner, Barbara W.; Hull, Richard A.; Darouiche, Rabih O.

    2010-01-01

    Purpose of review The underlying cause of catheter-associated urinary tract infection is biofilm formation by uropathogens on the urinary catheter. Biofilm is a relatively new concept in medicine, and current measures to prevent biofilm formation are inadequate. Considerable work is being done in this area, but little clinical progress has been made. The purpose of this review is to analyze recent publications concerning prevention of catheter-associated urinary tract infection. Recent findings Several recent studies have elucidated aspects of biofilm formation in catheter-associated urinary tract infection. Other researchers are working on methods to disrupt biofilm formation on catheter surfaces. At the same time, the magnitude of the problem of catheter-associated urinary tract infection has increased awareness of the effectiveness of basic infection control measures. A modern approach to infection control may include computerized ordering systems that minimize unnecessary days of catheterization. Finally, consumption of cranberry juice products and bacterial interference are two novel approaches to urinary tract infection prevention. Summary Biofilm-disrupting strategies offer promise for the future but have little immediate applicability. Implementation of infection control measures to improve catheter function and remove unnecessary catheters can be done at the present time. In general, prevention of catheter-associated urinary tract infection remains an elusive goal. More basic research at the level of pathogenesis is needed so that novel strategies can be designed. PMID:15647698

  12. FAQs about Catheter-Associated Urinary Tract Infection

    MedlinePlus

    ... and nurses take the following actions. Catheter insertion o Catheters are put in only when necessary and they are removed as soon as possible. o Only properly trained persons insert catheters using sterile (“ ...

  13. Airway smooth muscle in airway reactivity and remodeling: what have we learned?

    PubMed Central

    2013-01-01

    It is now established that airway smooth muscle (ASM) has roles in determining airway structure and function, well beyond that as the major contractile element. Indeed, changes in ASM function are central to the manifestation of allergic, inflammatory, and fibrotic airway diseases in both children and adults, as well as to airway responses to local and environmental exposures. Emerging evidence points to novel signaling mechanisms within ASM cells of different species that serve to control diverse features, including 1) [Ca2+]i contractility and relaxation, 2) cell proliferation and apoptosis, 3) production and modulation of extracellular components, and 4) release of pro- vs. anti-inflammatory mediators and factors that regulate immunity as well as the function of other airway cell types, such as epithelium, fibroblasts, and nerves. These diverse effects of ASM “activity” result in modulation of bronchoconstriction vs. bronchodilation relevant to airway hyperresponsiveness, airway thickening, and fibrosis that influence compliance. This perspective highlights recent discoveries that reveal the central role of ASM in this regard and helps set the stage for future research toward understanding the pathways regulating ASM and, in turn, the influence of ASM on airway structure and function. Such exploration is key to development of novel therapeutic strategies that influence the pathophysiology of diseases such as asthma, chronic obstructive pulmonary disease, and pulmonary fibrosis. PMID:24142517

  14. Central Venous Catheter (Central Line)

    MedlinePlus

    ... the skin entry site. With care, central venous catheters can remain in the body for several months without becoming infected. ■ ■ Blocking or kinking— Blood clots may begin to form in the catheter but ...

  15. Tissue factor pathway inhibitor prevents airway obstruction, respiratory failure and death due to sulfur mustard analog inhalation.

    PubMed

    Rancourt, Raymond C; Veress, Livia A; Ahmad, Aftab; Hendry-Hofer, Tara B; Rioux, Jacqueline S; Garlick, Rhonda B; White, Carl W

    2013-10-01

    Sulfur mustard (SM) inhalation causes airway injury, with enhanced vascular permeability, coagulation, and airway obstruction. The objective of this study was to determine whether recombinant tissue factor pathway inhibitor (TFPI) could inhibit this pathogenic sequence. Rats were exposed to the SM analog 2-chloroethyl ethyl sulfide (CEES) via nose-only aerosol inhalation. One hour later, TFPI (1.5mg/kg) in vehicle, or vehicle alone, was instilled into the trachea. Arterial O2 saturation was monitored using pulse oximetry. Twelve hours after exposure, animals were euthanized and bronchoalveolar lavage fluid (BALF) and plasma were analyzed for prothrombin, thrombin-antithrombin complex (TAT), active plasminogen activator inhibitor-1 (PAI-1) levels, and fluid fibrinolytic capacity. Lung steady-state PAI-1 mRNA was measured by RT-PCR analysis. Airway-capillary leak was estimated by BALF protein and IgM, and by pleural fluid measurement. In additional animals, airway cast formation was assessed by microdissection and immunohistochemical detection of airway fibrin. Airway obstruction in the form of fibrin-containing casts was evident in central conducting airways of rats receiving CEES. TFPI decreased cast formation, and limited severe hypoxemia. Findings of reduced prothrombin consumption, and lower TAT complexes in BALF, demonstrated that TFPI acted to limit thrombin activation in airways. TFPI, however, did not appreciably affect CEES-induced airway protein leak, PAI-1 mRNA induction, or inhibition of the fibrinolytic activity present in airway surface liquid. Intratracheal administration of TFPI limits airway obstruction, improves gas exchange, and prevents mortality in rats with sulfur mustard-analog-induced acute lung injury. Copyright © 2013 Elsevier Inc. All rights reserved.

  16. Difficult airway response team: a novel quality improvement program for managing hospital-wide airway emergencies.

    PubMed

    Mark, Lynette J; Herzer, Kurt R; Cover, Renee; Pandian, Vinciya; Bhatti, Nasir I; Berkow, Lauren C; Haut, Elliott R; Hillel, Alexander T; Miller, Christina R; Feller-Kopman, David J; Schiavi, Adam J; Xie, Yanjun J; Lim, Christine; Holzmueller, Christine; Ahmad, Mueen; Thomas, Pradeep; Flint, Paul W; Mirski, Marek A

    2015-07-01

    Difficult airway cases can quickly become emergencies, increasing the risk of life-threatening complications or death. Emergency airway management outside the operating room is particularly challenging. We developed a quality improvement program-the Difficult Airway Response Team (DART)-to improve emergency airway management outside the operating room. DART was implemented by a team of anesthesiologists, otolaryngologists, trauma surgeons, emergency medicine physicians, and risk managers in 2005 at The Johns Hopkins Hospital in Baltimore, Maryland. The DART program had 3 core components: operations, safety, and education. The operations component focused on developing a multidisciplinary difficult airway response team, standardizing the emergency response process, and deploying difficult airway equipment carts throughout the hospital. The safety component focused on real-time monitoring of DART activations and learning from past DART events to continuously improve system-level performance. This objective entailed monitoring the paging system, reporting difficult airway events and DART activations to a Web-based registry, and using in situ simulations to identify and mitigate defects in the emergency airway management process. The educational component included development of a multispecialty difficult airway curriculum encompassing case-based lectures, simulation, and team building/communication to ensure consistency of care. Educational materials were also developed for non-DART staff and patients to inform them about the needs of patients with difficult airways and ensure continuity of care with other providers after discharge. Between July 2008 and June 2013, DART managed 360 adult difficult airway events comprising 8% of all code activations. Predisposing patient factors included body mass index >40, history of head and neck tumor, prior difficult intubation, cervical spine injury, airway edema, airway bleeding, and previous or current tracheostomy. Twenty

  17. Difficult Airway Response Team: A Novel Quality Improvement Program for Managing Hospital-Wide Airway Emergencies

    PubMed Central

    Mark, Lynette J.; Herzer, Kurt R.; Cover, Renee; Pandian, Vinciya; Bhatti, Nasir I.; Berkow, Lauren C.; Haut, Elliott R.; Hillel, Alexander T.; Miller, Christina R.; Feller-Kopman, David J.; Schiavi, Adam J.; Xie, Yanjun J.; Lim, Christine; Holzmueller, Christine; Ahmad, Mueen; Thomas, Pradeep; Flint, Paul W.; Mirski, Marek A.

    2015-01-01

    Background Difficult airway cases can quickly become emergencies, increasing the risk of life-threatening complications or death. Emergency airway management outside the operating room is particularly challenging. Methods We developed a quality improvement program—the Difficult Airway Response Team (DART)—to improve emergency airway management outside the operating room. DART was implemented by a team of anesthesiologists, otolaryngologists, trauma surgeons, emergency medicine physicians, and risk managers in 2005 at The Johns Hopkins Hospital in Baltimore, Maryland. The DART program had three core components: operations, safety, and education. The operations component focused on developing a multidisciplinary difficult airway response team, standardizing the emergency response process, and deploying difficult airway equipment carts throughout the hospital. The safety component focused on real-time monitoring of DART activations and learning from past DART events to continuously improve system-level performance. This objective entailed monitoring the paging system, reporting difficult airway events and DART activations to a web-based registry, and using in situ simulations to identify and mitigate defects in the emergency airway management process. The educational component included development of a multispecialty difficult airway curriculum encompassing case-based lectures, simulation, and team building/communication to ensure consistency of care. Educational materials were also developed for non-DART staff and patients to inform them about the needs of patients with difficult airways and ensure continuity of care with other providers after discharge. Results Between July 2008 and June 2013, DART managed 360 adult difficult airway events comprising 8% of all code activations. Predisposing patient factors included body mass index > 40, history of head and neck tumor, prior difficult intubation, cervical spine injury, airway edema, airway bleeding, and previous

  18. Insertion of the endotracheal tube, laryngeal mask airway and oesophageal-tracheal Combitube. A 6-month comparative prospective study of acquisition and retention skills by medical students.

    PubMed

    Weksler, N; Tarnopolski, A; Klein, M; Schily, M; Rozentsveig, V; Shapira, A R; Gurman, G M

    2005-05-01

    To assess the ability of medical students to learn and retain skills of airway manipulation for insertion of the endotracheal tube, the laryngeal mask airway (Laryngeal Mask Company, Henley-on-Thames, UK) and the oesophageal-tracheal Combitube (Kendall-Sheridan Catheter Corp., Argyle, NY, USA). A 6-month prospective study was conducted among fifth-year medical students attending a 3-week clerkship in the Division of Anesthesiology and Critical Care Medicine in the Soroka Medical Center. All the students viewed a demonstration of insertion technique for the endotracheal tube, the laryngeal mask airway and the Combitube, followed by formal teaching in a mannikin. At the end of the program, the insertion skills were demonstrated in the mannikin, the success rate on the first attempt was registered and the students were requested to assess (by questionnaire) their ability to execute airway manipulation (phase 1). Six months later, the students were requested to repeat the insertion technique, and a similar re-evaluation applied (phase 2). The success rate, during the first phase, at first attempts was 100% for the laryngeal mask airway and the Combitube, compared to 57.4% for the endotracheal tube (P < 0.02), and 92.6%, 96.2% and 62.9% (P < 0.02) respectively for the second phase of the study. Learning and retention skills of medical students, in a mannikin, are more accentuated with the laryngeal mask airway and the Combitube than seen with an endotracheal tube.

  19. Usefulness of gram staining of blood collected from total parenteral nutrition catheter for rapid diagnosis of catheter-related sepsis.

    PubMed Central

    Moonens, F; el Alami, S; Van Gossum, A; Struelens, M J; Serruys, E

    1994-01-01

    The accuracy of Gram staining of blood drawn from catheters used to administer total parenteral nutrition was compared with paired quantitative blood cultures for the diagnosis of catheter-related sepsis. Gram staining was positive in 11 of 18 episodes of catheter-related sepsis documented by quantitative culture (sensitivity, 61%) but in none of the 5 episodes of fever unrelated to catheter infection. Thus, this procedure enabled the rapid presumptive diagnosis and guidance of antimicrobial therapy for total parenteral nutrition catheter sepsis, with a positive predictive value of 100% and a negative predictive value of 42%. PMID:7521359

  20. Histamine inhalation challenge in normal horses and in horses with small airway disease.

    PubMed Central

    Doucet, M Y; Vrins, A A; Ford-Hutchinson, A W

    1991-01-01

    A histamine inhalation challenge (HIC) procedure was developed to assess hyperreactive states in horses. Following clinical evaluation, percutaneous lung biopsies were performed on nine light breed mares aged 6 to 15 years. Five horses, with normal small airways, were classified as group A and four subjects with small airway disease (SAD) lesions formed group B. Pulmonary mechanics parameters were monitored following an aerosol of 0.9% saline and every 5 min for up to 30 min after HIC with 0.5% w/v of histamine diphosphate, administered through a face mask for 2.5 min. Tidal volume (VT) and airflow (V) values were obtained with a pneumotachograph. Transpulmonary pressure (delta Ppl) was measured by the esophageal balloon catheter method. Dynamic compliance (Cdyn), total pulmonary resistance (RL), end expiratory work of breathing (EEW) and respiratory rate (f) were calculated by a pulmonary mechanics computer. Group A horses had increases in RL, and decreases in Cdyn whereas horses in group B were hyperreactive and showed greater changes in EEW, Cdyn, and delta Ppl but with a relatively lower variation of RL. One horse in clinical remission from SAD, but with a high biopsy score (group B), and one clinically normal horse belonging to group A showed marked hyperreactivity as shown by increases in EEW, maximum change in delta Ppl and RL and decreases in Cdyn. These results suggest that the HIC described can be used as a method to investigate airway hyperreactivity and SAD in horses. Images Fig. 1. PMID:1889039

  1. Laryngeal mask airway for airway control during percutaneous dilatational tracheostomy.

    PubMed

    Pratt, T; Bromilow, J

    2011-11-01

    Percutaneous dilatational tracheostomy is a common bedside procedure in critical care for patients requiring prolonged mechanical ventilation. The traditional technique requires withdrawal of the endotracheal tube to a proximal position to facilitate tracheostomy insertion, but this carries the risk of inadvertent extubation and does not prevent cuff rupture. Use of a supraglottic airway such as the laryngeal mask airway may avoid these risks and could provide a safe alternative to the endotracheal tube. We present an appraisal of the literature to date. We found reasonable evidence to show improved ventilation and bronchoscopic visualisation with the laryngeal mask airway, but this has not been translated into improved outcome. There is currently insufficient evidence to draw conclusions about the safety of the laryngeal mask airway during percutaneous dilatational tracheostomy.

  2. Tissue factor pathway inhibitor prevents airway obstruction, respiratory failure and death due to sulfur mustard analog inhalation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rancourt, Raymond C., E-mail: raymond.rancourt@ucdenver.edu; Veress, Livia A., E-mail: livia.veress@ucdenver.edu; Ahmad, Aftab, E-mail: aftab.ahmad@ucdenver.edu

    Sulfur mustard (SM) inhalation causes airway injury, with enhanced vascular permeability, coagulation, and airway obstruction. The objective of this study was to determine whether recombinant tissue factor pathway inhibitor (TFPI) could inhibit this pathogenic sequence. Methods: Rats were exposed to the SM analog 2-chloroethyl ethyl sulfide (CEES) via nose-only aerosol inhalation. One hour later, TFPI (1.5 mg/kg) in vehicle, or vehicle alone, was instilled into the trachea. Arterial O{sub 2} saturation was monitored using pulse oximetry. Twelve hours after exposure, animals were euthanized and bronchoalveolar lavage fluid (BALF) and plasma were analyzed for prothrombin, thrombin–antithrombin complex (TAT), active plasminogen activatormore » inhibitor-1 (PAI-1) levels, and fluid fibrinolytic capacity. Lung steady-state PAI-1 mRNA was measured by RT-PCR analysis. Airway-capillary leak was estimated by BALF protein and IgM, and by pleural fluid measurement. In additional animals, airway cast formation was assessed by microdissection and immunohistochemical detection of airway fibrin. Results: Airway obstruction in the form of fibrin-containing casts was evident in central conducting airways of rats receiving CEES. TFPI decreased cast formation, and limited severe hypoxemia. Findings of reduced prothrombin consumption, and lower TAT complexes in BALF, demonstrated that TFPI acted to limit thrombin activation in airways. TFPI, however, did not appreciably affect CEES-induced airway protein leak, PAI-1 mRNA induction, or inhibition of the fibrinolytic activity present in airway surface liquid. Conclusions: Intratracheal administration of TFPI limits airway obstruction, improves gas exchange, and prevents mortality in rats with sulfur mustard-analog-induced acute lung injury. - Highlights: • TFPI administration to rats after mustard inhalation reduces airway cast formation. • Inhibition of thrombin activation is the likely mechanism for limiting casts. • Rats

  3. [Peripheral intravenous catheter-related phlebitis].

    PubMed

    van der Sar-van der Brugge, Simone; Posthuma, E F M Ward

    2011-01-01

    Phlebitis is a very common complication of the use of intravenous catheters. Two patients with an i.v. catheter complicated by thrombophlebitis are described. Patient A was immunocompromised due to chronic lymphatic leukaemia and developed septic thrombophlebitis with positive blood cultures for S. Aureus. Patient B was being treated with flucloxacillin because of an S. Aureus infection and developed chemical phlebitis. Septic phlebitis is rare, but potentially serious. Chemical or mechanical types of thrombophlebitis are usually less severe, but happen very frequently. Risk factors include: female sex, previous episode of phlebitis, insertion at (ventral) forearm, emergency placement and administration of antibiotics. Until recently, routine replacement of peripheral intravenous catheters after 72-96 h was recommended, but randomised controlled trials have not shown any benefit of this routine. A recent Cochrane Review recommends replacement of peripheral intravenous catheters when clinically indicated only.

  4. Use of a Novel Airway Kit and Simulation in Resident Training on Emergent Pediatric Airways.

    PubMed

    Melzer, Jonathan M; Hamersley, Erin R S; Gallagher, Thomas Q

    2017-06-01

    Objective Development of a novel pediatric airway kit and implementation with simulation to improve resident response to emergencies with the goal of improving patient safety. Methods Prospective study with 9 otolaryngology residents (postgraduate years 1-5) from our tertiary care institution. Nine simulated pediatric emergency airway drills were carried out with the existing system and a novel portable airway kit. Response times and time to successful airway control were noted with both the extant airway system and the new handheld kit. Results were analyzed to ensure parametric data and compared with t tests. A Bonferroni adjustment indicated that an alpha of 0.025 was needed for significance. Results Use of the airway kit significantly reduced the mean time of resident arrival by 47% ( P = .013) and mean time of successful intubation by 50% ( P = .007). Survey data indicated 100% improved resident comfort with emergent airway scenarios with use of the kit. Discussion Times to response and meaningful intervention were significantly reduced with implementation of the handheld airway kit. Use of simulation training to implement the new kit improved residents' comfort and airway skills. This study describes an affordable novel mobile airway kit and demonstrates its ability to improve response times. Implications for Practice The low cost of this airway kit makes it a tenable option even for smaller hospitals. Simulation provides a safe and effective way to familiarize oneself with novel equipment, and, when possible, realistic emergent airway simulations should be used to improve provider performance.

  5. Respiratory gas conditioning in infants with an artificial airway.

    PubMed

    Schulze, Andreas

    2002-10-01

    There is a strong physiological rationale for delivering the inspiratory gas at or close to core body temperature and saturated with water vapour to infants with an artificial airway undergoing long-term mechanical ventilatory assistance. Cascade humidifiers with heated wire ventilatory circuitry may achieve this goal safely. Whenever saturated air leaves the humidifier chamber at 37 degrees C and condensate accumulates in the circuit, the gas loses humidity and acquires the potential to dry airway secretions near the tip of the endotracheal tube. Heat and moisture exchangers and hygroscopic condenser humidifiers with or without bacterial filters have become available for neonates. They can provide sufficient moisture output for short-term ventilation without excessive additional dead space or flow-resistive load for term infants. Their safety and efficacy for very low birthweight infants and for long-term mechanical ventilation has not been established conclusively. A broader application of these inexpensive and simple devices is likely to occur with further design improvements. When heated humidifiers are appropriately applied, water or normal saline aerosol application offers no additional significant advantage in terms of inspiratory gas conditioning and may impose a water overload on the airway or even systemically. Although airway irrigation by periodic bolus instillation of normal saline solution prior to suctioning procedures is widely practised in neonatology, virtually no data exist on its safety and efficacy when used with appropriately humidified inspired gas. There is no evidence that conditioning of inspired gas to core body temperature and full water vapour saturation may promote nosocomial respiratory infections.

  6. Efficacy of Surgical Airway Plasty for Benign Airway Stenosis.

    PubMed

    Tsukioka, Takuma; Takahama, Makoto; Nakajima, Ryu; Kimura, Michitaka; Inoue, Hidetoshi; Yamamoto, Ryoji

    2016-01-01

    Long-term patency is required during treatment for benign airway stenosis. This study investigated the effectiveness of surgical airway plasty for benign airway stenosis. Clinical courses of 20 patients, who were treated with surgical plasty for their benign airway stenosis, were retrospectively investigated. Causes of stenosis were tracheobronchial tuberculosis in 12 patients, post-intubation stenosis in five patients, malacia in two patients, and others in one patient. 28 interventional pulmonology procedures and 20 surgical plasty were performed. Five patients with post-intubation stenosis and four patients with tuberculous stenosis were treated with tracheoplasty. Eight patients with tuberculous stenosis were treated with bronchoplasty, and two patients with malacia were treated with stabilization of the membranous portion. Anastomotic stenosis was observed in four patients, and one to four additional treatments were required. Performance status, Hugh-Jones classification, and ventilatory functions were improved after surgical plasty. Outcomes were fair in patients with tuberculous stenosis and malacia. However, efficacy of surgical plasty for post-intubation stenosis was not observed. Surgical airway plasty may be an acceptable treatment for tuberculous stenosis. Patients with malacia recover well after surgical plasty. There may be untreated patients with malacia who have the potential to benefit from surgical plasty.

  7. Efficacy of Surgical Airway Plasty for Benign Airway Stenosis

    PubMed Central

    Takahama, Makoto; Nakajima, Ryu; Kimura, Michitaka; Inoue, Hidetoshi; Yamamoto, Ryoji

    2015-01-01

    Background: Long-term patency is required during treatment for benign airway stenosis. This study investigated the effectiveness of surgical airway plasty for benign airway stenosis. Methods: Clinical courses of 20 patients, who were treated with surgical plasty for their benign airway stenosis, were retrospectively investigated. Results: Causes of stenosis were tracheobronchial tuberculosis in 12 patients, post-intubation stenosis in five patients, malacia in two patients, and others in one patient. 28 interventional pulmonology procedures and 20 surgical plasty were performed. Five patients with post-intubation stenosis and four patients with tuberculous stenosis were treated with tracheoplasty. Eight patients with tuberculous stenosis were treated with bronchoplasty, and two patients with malacia were treated with stabilization of the membranous portion. Anastomotic stenosis was observed in four patients, and one to four additional treatments were required. Performance status, Hugh–Jones classification, and ventilatory functions were improved after surgical plasty. Outcomes were fair in patients with tuberculous stenosis and malacia. However, efficacy of surgical plasty for post-intubation stenosis was not observed. Conclusion: Surgical airway plasty may be an acceptable treatment for tuberculous stenosis. Patients with malacia recover well after surgical plasty. There may be untreated patients with malacia who have the potential to benefit from surgical plasty. PMID:26567879

  8. Airway surface liquid homeostasis in cystic fibrosis: pathophysiology and therapeutic targets.

    PubMed

    Haq, Iram J; Gray, Michael A; Garnett, James P; Ward, Christopher; Brodlie, Malcolm

    2016-03-01

    Cystic fibrosis (CF) is a life-limiting disease characterised by recurrent respiratory infections, inflammation and lung damage. The volume and composition of the airway surface liquid (ASL) are important in maintaining ciliary function, mucociliary clearance and antimicrobial properties of the airway. In CF, these homeostatic mechanisms are impaired, leading to a dehydrated and acidic ASL. ASL volume depletion in CF is secondary to defective anion transport by the abnormal cystic fibrosis transmembrane conductance regulator protein (CFTR). Abnormal CFTR mediated bicarbonate transport creates an unfavourable, acidic environment, which impairs antimicrobial function and alters mucus properties and clearance. These disease mechanisms create a disordered airway milieu, consisting of thick mucopurulent secretions and chronic bacterial infection. In addition to CFTR, there are additional ion channels and transporters in the apical airway epithelium that play a role in maintaining ASL homeostasis. These include the epithelial sodium channel (ENaC), the solute carrier 26A (SLC26A) family of anion exchangers, and calcium-activated chloride channels. In this review we discuss how the ASL is abnormal in CF and how targeting these alternative channels and transporters could provide an attractive therapeutic strategy to correct the underlying ASL abnormalities evident in CF. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  9. Application of paclitaxel as adjuvant treatment for benign cicatricial airway stenosis.

    PubMed

    Qiu, Xiao-Jian; Zhang, Jie; Wang, Juan; Wang, Yu-Ling; Xu, Min

    2016-12-01

    Benign cicatricial airway stenosis (BCAS) is a potentially life-threatening disease. Recurrence occurs frequently after endoscopic treatment. Paclitaxel is known to prevent restenosis, but its clinical efficacy and safety is undetermined. Therefore, in this study, we investigated the efficacy and associated complications of paclitaxel as adjuvant treatment for BCAS of different etiologies. The study cohort included 28 patients with BCAS resulting from tuberculosis, intubation, tracheotomy, and other etiologies. All patients were treated at the Department of Respiratory Diseases, Beijing Tian Tan Hospital, Capital Medical University, China, between January 2010 and August 2014. After primary treatment by balloon dilation, cryotherapy, and/or high-frequency needle-knife treatment, paclitaxel was applied to the airway mucosa at the site of stenosis using a newly developed local instillation catheter. The primary outcome measures were the therapeutic efficacy of paclitaxel as adjuvant treatment, and the incidence of complications was observed as well. According to our criteria for evaluating the clinical effects on BCAS, 24 of the 28 cases achieved durable remission, three cases had remission, and one case showed no remission. Thus, the durable remission rate was 85.7%, and the combined effective rate was 96.4%. No differences in outcomes were observed among the different BCAS etiologies (P=0.144), and few complications were observed. Our results indicated that paclitaxel as an adjuvant treatment has greater efficacy than previously reported BCAS treatment methods.

  10. Catheter-based photoacoustic endoscope

    PubMed Central

    Yang, Joon-Mo; Li, Chiye; Chen, Ruimin; Zhou, Qifa; Shung, K. Kirk; Wang, Lihong V.

    2014-01-01

    Abstract. We report a flexible shaft-based mechanical scanning photoacoustic endoscopy (PAE) system that can be potentially used for imaging the human gastrointestinal tract via the instrument channel of a clinical video endoscope. The development of such a catheter endoscope has been an important challenge to realize the technique’s benefits in clinical settings. We successfully implemented a prototype PAE system that has a 3.2-mm diameter and 2.5-m long catheter section. As the instrument’s flexible shaft and scanning tip are fully encapsulated in a plastic catheter, it easily fits within the 3.7-mm diameter instrument channel of a clinical video endoscope. Here, we demonstrate the intra-instrument channel workability and in vivo animal imaging capability of the PAE system. PMID:24887743

  11. 21 CFR 868.5120 - Anesthesia conduction catheter.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Anesthesia conduction catheter. 868.5120 Section... (CONTINUED) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5120 Anesthesia conduction catheter. (a) Identification. An anesthesia conduction catheter is a flexible tubular device used to inject...

  12. 21 CFR 868.5120 - Anesthesia conduction catheter.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Anesthesia conduction catheter. 868.5120 Section... (CONTINUED) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5120 Anesthesia conduction catheter. (a) Identification. An anesthesia conduction catheter is a flexible tubular device used to inject...

  13. 21 CFR 868.5120 - Anesthesia conduction catheter.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Anesthesia conduction catheter. 868.5120 Section... (CONTINUED) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5120 Anesthesia conduction catheter. (a) Identification. An anesthesia conduction catheter is a flexible tubular device used to inject...

  14. S-Nitroso-N-acetylpenicillamine (SNAP) Impregnated Silicone Foley Catheters: A Potential Biomaterial/Device To Prevent Catheter-Associated Urinary Tract Infections

    PubMed Central

    2016-01-01

    Urinary Foley catheters are utilized for management of hospitalized patients and are associated with high rates of urinary tract infections (UTIs). Nitric oxide (NO) potently inhibits microbial biofilm formation, which is the primary cause of catheter associated UTIs (CAUTIs). Herein, commercial silicone Foley catheters are impregnated via a solvent swelling method with S-nitroso-N-acetyl-D-penicillamine (SNAP), a synthetic NO donor that exhibits long-term NO release and stability when incorporated into low water-uptake polymers. The proposed catheters generate NO surface-fluxes >0.7 × 10–10 mol min–1 cm–2 for over one month under physiological conditions, with minimal SNAP leaching. These biomedical devices are demonstrated to significantly decrease formation of biofilm on the surface of the catheter tubings over 3, 7, and 14 day periods by microbial species (Staphylococcus epidermidis and Proteus mirabilis) commonly causing CAUTIs. Toxicity assessment demonstrates that the SNAP-impregnated catheters are fully biocompatible, as extracts of the catheter tubings score 0 on a 3-point grading scale using an accepted mouse fibroblast cell-line toxicity model. Consequently, SNAP-impregnated silicone Foley catheters can likely provide an efficient strategy to greatly reduce the occurrence of nosocomial CAUTIs. PMID:26462294

  15. Early removal of urethral catheter with suprapubic tube drainage versus urethral catheter drainage alone after robot-assisted laparoscopic radical prostatectomy.

    PubMed

    Prasad, Sandip M; Large, Michael C; Patel, Amit R; Famakinwa, Olufenwa; Galocy, R Matthew; Karrison, Theodore; Shalhav, Arieh L; Zagaja, Gregory P

    2014-07-01

    Retrospective single institution data suggest that postoperative pain after robot-assisted laparoscopic radical prostatectomy is decreased by early removal of the urethral catheter with suprapubic tube drainage. In a randomized patient population we determined whether suprapubic tube drainage with early urethral catheter removal would improve postoperative pain compared with urethral catheter drainage alone. Men with a body mass index of less than 40 kg/m(2) who had newly diagnosed prostate cancer and elected robot-assisted laparoscopic radical prostatectomy were included in analysis. Block randomization by surgeon was used and randomization assignment was done after completing the urethrovesical anastomosis. In patients assigned to suprapubic tube drainage the urethral catheter was removed on postoperative day 1 and all catheters were removed on postoperative day 7. Visual analog pain scale and satisfaction questionnaires were administered on postoperative days 0, 1 and 7. A total of 29 patients were randomized to the urethral catheter vs 29 to the suprapubic tube plus early urethral catheter removal at the time of interim futility analysis. Mean visual analog pain scale scores did not differ between the groups at any time point and a similar percent of patients cited the catheter as the greatest bother with nonsignificant differences in treatment related satisfaction. Complications during postoperative week 1 did not vary between the groups. Based on interim results the trial was terminated due to lack of effect. Patients randomized to suprapubic tube vs urethral catheter drainage for the week after prostatectomy had similar pain, catheter related bother and treatment related satisfaction in the perioperative period. We no longer routinely offer suprapubic tube drainage with early urethral catheter removal at our institution. Copyright © 2014 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  16. The dangers of long-term catheter drainage.

    PubMed

    Lowthian, P

    There are many dangers associated with long-term urinary bladder drainage by catheter. For various reasons, the choice of catheter is important, and its initial insertion can be particularly hazardous. All catheterizations should, however, be safer when there is some urine (or other fluid) in the bladder. The appropriate choice of drainage system attached to the catheter can delay bacterial invasion of the bladder. Great care is needed to prevent blockage of the system, particularly when bacteriuria is present. Recent evidence indicates that some bacteria encourage the development of encrustations, so that, in some circumstances, catheters may become blocked within 24 hours. This, together with other considerations, strongly suggests that indwelling catheters should be changed at intervals of not more than 5 days. The practical implications of this are considered, as are the benefits that may accrue. Accidental catheter traction is another danger, and some possible methods of avoiding this are discussed. Finally, the need for a new kind of drainage-bag support is highlighted.

  17. Heart catheter cable and connector

    NASA Technical Reports Server (NTRS)

    Harrison, D. R.; Cota, F. L.; Sandler, H.

    1972-01-01

    Ultraminiature catheter cables that are stiff enough for intravenous insertion yet flexible at the tip, sterilizable, and economical are fabricated entirely from commercially available parts. Assembly includes air passageway for reference pressures and coaxial cable for transmission of signals from the tip of catheter.

  18. Hydrophilic-coated catheters for intermittent catheterisation reduce urethral micro trauma: a prospective, randomised, participant-blinded, crossover study of three different types of catheters.

    PubMed

    Stensballe, J; Looms, D; Nielsen, P N; Tvede, M

    2005-12-01

    To compare two hydrophilic-coated (SpeediCath and LoFric and one uncoated gel-lubricated catheter (InCare Advance Plus) concerning withdrawal friction force and urethral micro trauma. 49 healthy male volunteers participated in this prospective, randomised, blinded, crossover study of three different bladder catheters. The withdrawal friction force was measured, and urine analysis of blood, nitrite and leucocytes, microbiological analysis of urine cultures and subjective evaluation of the catheters were performed. 40 participants completed the study and were included in the analysis. SpeediCath exerted a significantly lower mean withdrawal friction force and work than the gel-lubricated uncoated catheter, whereas LoFric exerted a significantly higher mean friction force than both of the other catheters. The hydrophilic catheters caused less microscopic haematuria and less pain than the gel-lubricated uncoated catheter. Furthermore, 93% of the participants preferred the hydrophilic catheters. Hydrophilic-coated catheters perform better than uncoated catheters with regard to haematuria and preference. SpeediCath, but not LoFric, exerts less withdrawal friction force than InCare Advance Plus.

  19. Airway management in neuroanesthesiology.

    PubMed

    Aziz, Michael

    2012-06-01

    Airway management for neuroanesthesiology brings together some key principles that are shared throughout neuroanesthesiology. This article appropriately targets the cervical spine with associated injury and the challenges surrounding airway management. The primary focus of this article is on the unique airway management obstacles encountered with cervical spine injury or cervical spine surgery, and unique considerations regarding functional neurosurgery are addressed. Furthermore, topics related to difficult airway management for those with rheumatoid arthritis or pituitary surgery are reviewed. Copyright © 2012 Elsevier Inc. All rights reserved.

  20. [The research on the airway hyperresponsiveness and IOS airway resistance index of industrial area resident].

    PubMed

    Xu, Jin; Wang, Zhen; Sun, Hongcun

    2015-09-01

    To study airway reactivity and impulse oscillation (IOS)-measured airway resistance indicators of residents of Zhenhai industrial area in Ningbo city. In the form of follow-up, both. airway reactivity and respiratory functions of populations in Zhenhai industrial zone (n = 215) and urban (n = 203) were measured, comparing difference degree between different regions. Ninty-five of 215 cases in industrial area were identified as suspected airway hyperresponsiveness, but only 43 of 203 cases were in urban areas. Forty-seven of 95 cases (49.5%) in industrial zone were positive, while only 14 cases (32.6%) in urban. The proportions of people in the two regions on different types of airway hyperresponsiveness were significantly different (P < 0.01). All airway resistance indexes of urban populations were significantly lower than that of industrial zone (P < 0.05). The prevalence of airway hyperresponsiveness and IOS airway resistance aspects of industrial area residents was higher than that of urban residents. Monitoring and evaluating the airway diseases, inflammatory lesions and respiratory function in the region were good for understanding the severe pollution in the local area in certain significance.

  1. Reducing catheter-related thrombosis using a risk reduction tool centered on catheter to vessel ratio.

    PubMed

    Spencer, Timothy R; Mahoney, Keegan J

    2017-11-01

    In vascular access practices, the internal vessel size is considered important, and a catheter to vessel ratio (CVR) is recommended to assist clinicians in selecting the most appropriate-sized device for the vessel. In 2016, new practice recommendations stated that the CVR can increase from 33 to 45% of the vessels diameter. There has been evidence on larger diameter catheters and increased thrombosis risk in recent literature, while insufficient information established on what relationship to vessel size is appropriate for any intra-vascular device. Earlier references to clinical standards and guidelines did not clearly address vessel size in relation to the area consumed or external catheter diameter. The aim of this manuscript is to present catheter-related thrombosis evidence and develop a standardized process of ultrasound-guided vessel assessment, integrating CVR, Virchow's triad phenomenon and vessel health and preservation strategies, empowering an evidence-based approach to device placement. Through review, calculation and assessment on the areas of the 33 and 45% rule, a preliminary clinical tool was developed to assist clinicians make cognizant decisions when placing intravascular devices relating to target vessel size, focusing on potential reduction in catheter-related thrombosis. Increasing the understanding and utilization of CVRs will lead to a safer, more consistent approach to device placement, with potential thrombosis reduction strategies. The future of evidence-based data relies on the clinician to capture accurate vessel measurements and device-related outcomes. This will lead to a more dependable data pool, driving the relationship of catheter-related thrombosis and vascular assessment.

  2. Emergency airway puncture

    MedlinePlus

    ... support for only a very short period of time. Alternative Names Needle cricothyrotomy Images Emergency airway puncture Cricoid cartilage Emergency airway puncture - series References Hebert RB, Bose S, Mace SE. Cricothyrotomy and ...

  3. 21 CFR 870.1330 - Catheter guide wire.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Catheter guide wire. 870.1330 Section 870.1330...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1330 Catheter guide wire. (a) Identification. A catheter guide wire is a coiled wire that is designed to fit inside a...

  4. 21 CFR 870.1330 - Catheter guide wire.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Catheter guide wire. 870.1330 Section 870.1330...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1330 Catheter guide wire. (a) Identification. A catheter guide wire is a coiled wire that is designed to fit inside a...

  5. 21 CFR 868.5350 - Nasal oxygen catheter.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Nasal oxygen catheter. 868.5350 Section 868.5350...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5350 Nasal oxygen catheter. (a) Identification. A nasal oxygen catheter is a device intended to be inserted through a patient's nostril to...

  6. 21 CFR 868.5350 - Nasal oxygen catheter.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Nasal oxygen catheter. 868.5350 Section 868.5350...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5350 Nasal oxygen catheter. (a) Identification. A nasal oxygen catheter is a device intended to be inserted through a patient's nostril to...

  7. 21 CFR 868.5350 - Nasal oxygen catheter.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Nasal oxygen catheter. 868.5350 Section 868.5350...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5350 Nasal oxygen catheter. (a) Identification. A nasal oxygen catheter is a device intended to be inserted through a patient's nostril to...

  8. 21 CFR 868.5350 - Nasal oxygen catheter.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Nasal oxygen catheter. 868.5350 Section 868.5350...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5350 Nasal oxygen catheter. (a) Identification. A nasal oxygen catheter is a device intended to be inserted through a patient's nostril to...

  9. 21 CFR 868.5350 - Nasal oxygen catheter.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Nasal oxygen catheter. 868.5350 Section 868.5350...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5350 Nasal oxygen catheter. (a) Identification. A nasal oxygen catheter is a device intended to be inserted through a patient's nostril to...

  10. Paravertebral block catheter breakage by electrocautery during thoracic surgery.

    PubMed

    Saeki, Noboru; Sugimoto, Yuki; Mori, Yoko; Kato, Takahiro; Miyoshi, Hirotsugu; Nakamura, Ryuji; Koga, Tomomichi

    2017-06-01

    Advantages of thoracic paravertebral analgesia (TPA) include placement of the catheter closer to the surgical field; however, the catheter can become damaged during the operation. We experienced a case of intraoperative TPA catheter breakage that prompted us to perform an experiment to investigate possible causes. A 50-year-old male underwent a thoracoscopic lower lobectomy under general anesthesia with TPA via an intercostal approach. Following surgery, it was discovered that the catheter had become occluded, as well as cut and fused, so we reopened the incision and removed the residual catheter. From that experience, we performed an experiment to examine electrocautery-induced damage in normal (Portex™, Smith's Medical), radiopaque (Perifix SoftTip™, BBraun), and reinforced (Perifix FX™, BBraun) epidural catheters (n = 8 each). Chicken meat was penetrated by each catheter and then cut by electrocautery. In the normal group, breakage occurred in 8 and occlusion in 6 of the catheters, and in the radiopaque group breakage occurred in 8 and occlusion in 7. In contrast, breakage occurred in only 3 and occlusion in none in the reinforced group, with the 5 without breakage remaining connected only by the spring coil. Furthermore, in 7 of the reinforced catheters, electric arc-induced thermal damage was observed at the tip of the catheter. A TPA catheter for thoracic surgery should be inserted via the median approach, or it should be inserted after surgery to avoid catheter damage during surgery.

  11. Incidence of phlebitis associated with the use of peripheral IV catheter and following catheter removal

    PubMed Central

    Urbanetto, Janete de Souza; Peixoto, Cibelle Grassmann; May, Tássia Amanda

    2016-01-01

    ABSTRACT Objective: to investigate the incidence of phlebitis and its association with risk factors when using peripheral IV catheters (PIC) and following their removal - (post-infusion phlebitis) in hospitalized adults. Method: a cohort study of 171 patients using PIC, totaling 361 punctures. Sociodemographic variables and variables associated with the catheter were collected. Descriptive and analytical statistical analyses were performed. Results: average patient age was 56.96 and 51.5% of the sample population was male. The incidence of phlebitis was 1.25% while using PIC, and 1.38% post-infusion. The incidence of phlebitis while using PIC was associated with the length of time the catheter remained in place, whereas post-infusion phlebitis was associated with puncture in the forearm. Ceftriaxone, Clarithromycin and Oxacillin are associated with post-infusion phlebitis. Conclusions: this study made it possible to investigate the association between risk factors and phlebitis during catheter use and following its removal. The frequency of post-infusion phlebitis was larger than the incidence of phlebitis with the catheter in place, with Phlebitis Grade III and II being the most frequently found in each of these situations, respectively. Aspects related to post-infusion phlebitis can be explained, given the limited number of studies addressing this theme from this perspective. PMID:27508916

  12. Allergic Sensitization through the Airway Primes Th17-dependent Neutrophilia and Airway Hyperresponsiveness

    PubMed Central

    Wilson, Rhonda H.; Whitehead, Gregory S.; Nakano, Hideki; Free, Meghan E.; Kolls, Jay K.; Cook, Donald N.

    2009-01-01

    Rationale: In humans, immune responses to inhaled aeroallergens develop in the lung and draining lymph nodes. Many animal models of asthma bypass this route and instead use intraperitoneal injections of allergen using aluminum hydroxide as an adjuvant. Objectives: We investigated whether allergic sensitization through the airway elicits immune responses qualitatively different than those arising in the peritoneum. Methods: Mice were sensitized to allergen through the airway using low-dose LPS as an adjuvant, or through the peritoneum using aluminum hydroxide as an adjuvant. After a single allergen challenge, ELISA and flow cytometry were used to measure cytokines and leukocyte subsets. Invasive measurements of airway resistance were used to measure allergen-induced airway hyperreactivity (AHR). Measurements and Main Results: Sensitization through the peritoneum primed strong Th2 responses and eosinophilia, but not AHR, after a single allergen challenge. By contrast, allergic sensitization through the airway primed only modest Th2 responses, but strong Th17 responses. Th17 cells homed to the lung and released IL-17 into the airway on subsequent encounter with inhaled allergen. As a result, these mice developed IL-17–dependent airway neutrophilia and AHR. This AHR was neutrophil-dependent because it was abrogated in CXCR2-deficient mice and also in wild-type mice receiving a neutrophil-depleting antibody. Individually, neither IL-17 nor ongoing Th2 responses were sufficient to confer AHR, but together they acted synergistically to promote neutrophil recruitment, eosinophil recruitment and AHR. Conclusions: Allergic sensitization through the airway primes modest Th2 responses but strong Th17 responses that promote airway neutrophilia and acute AHR. These findings support a causal role for neutrophils in severe asthma. PMID:19661246

  13. Careers in Airway Science.

    ERIC Educational Resources Information Center

    Federal Aviation Administration (DOT), Washington, DC.

    The Federal Aviation Administration (FAA) has initiated the Airway Science curriculum as a method of preparing the next generation of aviation technicians and managers. This document: (1) discusses the FAA's role in the Airway Science program; (2) describes some of the career fields that FAA offers to Airway Science graduates (air traffic control…

  14. Low-angled peripheral intravenous catheter tip placement decreases phlebitis.

    PubMed

    Tanabe, Hidenori; Murayama, Ryoko; Yabunaka, Koichi; Oe, Makoto; Takahashi, Toshiaki; Komiyama, Chieko; Sanada, Hiromi

    2016-11-02

    Peripheral intravenous catheters (PIVCs) are frequently removed due to phlebitis. We hypothesized that catheters made of polyurethane, which is more flexible than Teflon, would decrease phlebitis, and that flexibility could be estimated by measuring the catheter-tip angle. Ultrasonography in two groups of patients with different catheter types was then used to compare catheter-tip angles and phlebitis. Observational studies were carried out at a medical ward in a university hospital. Infusion therapy was administered to one group of patients in 2014 using Teflon catheters (control group, n = 200), and to another group of patients in 2015 using polyurethane catheters (investigational group, n = 207). The symptoms were assessed according to a scale developed by the Infusion Nurses Society. Long-axis ultrasonography images taken immediately before catheter removal were used to measure the angle between the central line of the catheter within 2 mm from the distal point and a tangent to the vessel wall. There were no significant differences between the two groups with respect to sex, age, and medical diagnosis. In the control and investigational groups, the rates of phlebitis were 37% (73/200) and 17% (36/207), respectively (p<0.001). The median angles of the catheter tip were 7.8° and 4.1°, respectively (p<0.001). Phlebitis occurred more frequently when the catheter-tip was placed at angle >5.8°. The frequency of phlebitis was lower in the polyurethane, in which the catheter was placed at lower angle, almost parallel to the vessel. Our results will aid in developing new catheters and in improving PIVC-securement techniques.

  15. Development of Bend Sensor for Catheter Tip

    NASA Astrophysics Data System (ADS)

    Nagano, Yoshitaka; Sano, Akihito; Fujimoto, Hideo

    Recently, a minimally invasive surgery which makes the best use of the catheter has been becoming more popular. In endovascular coil embolization for a cerebral aneurysm, the observation of the catheter's painting phenomenon is very important to execute the appropriate manipulation of the delivery wire and the catheter. In this study, the internal bend sensor which consists of at least two bending enhanced plastic optical fibers was developed in order to measure the curvature of the catheter tip. Consequently, the painting could be more sensitively detected in the neighborhood of the aneurysm. In this paper, the basic characteristics of the developed sensor system are described and its usefulness is confirmed from the comparison of the insertion force of delivery wire and the curvature of catheter tip in the experiment of coil embolization.

  16. A novel, inexpensive, double lumen suprapubic catheter for urodynamics.

    PubMed

    Wagner, Andrew A; Godley, Margaret L; Duffy, Patrick G; Ransley, Philip G

    2004-03-01

    We describe a novel, double lumen, intravesical, suprapubic catheter designed to meet the requirements of pediatric urodynamics that is easy to use and has minimal complications. A commercially available 10Fr pediatric suprapubic pigtail catheter forms the outer lumen for instilling filling media. A 16 gauge epidural catheter is inserted through the outer catheter providing an inner lumen for measuring intravesical pressures. The resultant double-lumen catheter is inserted suprapubically using a peel away needle supplied with the 10Fr catheter, with the patient under general anesthetic. The catheter has been used for 15 years in more than 700 patients with good reliability and few complications. The concentric construction of the double lumens and the rigidity of the inner intravesical pressure channel ensure there is no transmission of pressure from the filling channel to the inner lumen. The catheter has a circular cross section and a pigtail distal end which help to retain it within the bladder. There is low resistance to filling that allows adequate filling rates to be achieved by gravity rather than necessitating a pump. The catheter is easily made from readily available components and is less expensive than other double-lumen catheters suitable for suprapubic use. A reliable, double lumen catheter that fulfills criteria not found in commercially available alternatives can be inexpensively made for urodynamics.

  17. The physiological rationale of heat and moisture exchangers in post-laryngectomy pulmonary rehabilitation: a review.

    PubMed

    Zuur, J K; Muller, S H; de Jongh, F H C; van Zandwijk, N; Hilgers, F J M

    2006-01-01

    Total laryngectomy results in a permanent disconnection of the upper and lower airways and inevitably leads to chronic pulmonary complaints like frequent involuntary coughing, increased sputum production and repeated daily forced expectoration to clean the airway. Heat and moisture exchangers (HMEs), applied in an attempt to compensate for the lost functions of the upper respiratory tract, have been found to diminish these symptoms and improve the quality of life significantly. An HME has three physical properties that might be responsible for these improvements. First, its heat and moisture exchanging capacity improves intra-airway preservation of heat and water. Since the condensation and evaporation of moisture are accompanied by the release and uptake of thermal energy, these parameters are inseparable. Secondly, the HME's resistance may reduce dynamic airway compression, thereby improving ventilation. Thirdly, to some extent, an HME might filter out particles, thereby cleaning inspiratory breathing air. This article summarizes our present knowledge of changes in respiratory physiology after total laryngectomy and the influence of the HME by reviewing the physiological impact of these three physical properties separately for in vitro and in vivo data.

  18. OCT imaging in chronic obstructive pulmonary disease

    NASA Astrophysics Data System (ADS)

    Ohtani, K.; Lopez Lisbona, R. M.; Lee, A. M. D.; Hyun, C.; Shaipanich, T.; McWilliams, A.; Lane, P.; Coxson, H. O.; MacAulay, C.; Lam, S.

    2013-03-01

    Introduction: A recent ex-vivo study using micro-CT in patients with chronic obstructive pulmonary disease (COPD) showed that narrowing and disappearance of small conducting airways precedes the onset of emphysematous destruction in COPD. Until recently, the airway remodeling process could not be studied in detail in-vivo. In this study, we investigated the repeatability of navigating an Optical Coherence Tomography (OCT) catheter to image the same airways in smokers with and without COPD. Method: OCT imaging was performed by inserting the catheter through a sub-segmental airway to a small bronchiole. Three-dimensional OCT imaging of 5 cm of airway segments was obtained. The catheter was removed and reinsertion into the same airway was attempted. The number of airway generations and quantitative measurements of the airway wall area were investigated. Results: Sixty-three airways in 30 subjects were analyzed. Repeated insertion into the same airway was observed at 53.8 %, 92.3% and 70.8% of the time in the upper, middle and lower lobes respectively. The percentage differences of paired measurements of airway wall area between matched and unmatched airways in bronchioles were 5.8 +/- 4.6 % and 7.3 +/- 5.4 % respectively Conclusions: Repeated OCT imaging of airways is possible in the majority of cases except in the upper lobes. For airways that are not completely matched, some of the airway segments can still be used for comparison by careful alignment of the airway. OCT may be a useful method to study the remodeling process in small airways and the effect of therapeutic intervention.

  19. Relapsing polychondritis and airway involvement.

    PubMed

    Ernst, Armin; Rafeq, Samaan; Boiselle, Phillip; Sung, Arthur; Reddy, Chakravarthy; Michaud, Gaetane; Majid, Adnan; Herth, Felix J F; Trentham, David

    2009-04-01

    To assess the prevalence and characteristics of airway involvement in relapsing polychondritis (RP). Retrospective chart review and data analysis of RP patients seen in the Rheumatology Clinic and the Complex Airway Center at Beth Israel Deaconess Medical Center from January 2004 through February 2008. RP was diagnosed in 145 patients. Thirty-one patients had airway involvement, a prevalence of 21%. Twenty-two patients were women (70%), and they were between 11 and 61 years of age (median age, 42 years) at the time of first symptoms. Airway symptoms were the first manifestation of disease in 17 patients (54%). Dyspnea was the most common symptom in 20 patients (64%), followed by cough, stridor, and hoarseness. Airway problems included the following: subglottic stenosis (n = 8; 26%); focal and diffuse malacia (n = 15; 48%); and focal stenosis in different areas of the bronchial tree in the rest of the patients. Twelve patients (40%) required and underwent intervention including balloon dilatation, stent placement, tracheotomy, or a combination of the above with good success. The majority of patients experienced improvement in airway symptoms after intervention. One patient died during the follow-up period from the progression of airway disease. The rest of the patients continue to undergo periodic evaluation and intervention. In this largest cohort described in the English language literature, we found symptomatic airway involvement in RP to be common and at times severe. The nature of airway problems is diverse, with tracheomalacia being the most common. Airway intervention is frequently required and in experienced hands results in symptom improvement.

  20. Airway recovery after face transplantation.

    PubMed

    Fischer, Sebastian; Wallins, Joe S; Bueno, Ericka M; Kueckelhaus, Maximilian; Chandawarkar, Akash; Diaz-Siso, J Rodrigo; Larson, Allison; Murphy, George F; Annino, Donald J; Caterson, Edward J; Pomahac, Bohdan

    2014-12-01

    Severe facial injuries can compromise the upper airway by reducing airway volume, obstructing or obliterating the nasal passage, and interfering with oral airflow. Besides the significant impact on quality of life, upper airway impairments can have life-threatening or life-altering consequences. The authors evaluated improvements in functional airway after face transplantation. Between 2009 and 2011, four patients underwent face transplantation at the authors' institution, the Brigham and Women's Hospital. Patients were examined preoperatively and postoperatively and their records reviewed for upper airway infections and sleeping disorders. The nasal mucosa was biopsied after face transplantation and analyzed using scanning electron microscopy. Volumetric imaging software was used to evaluate computed tomographic scans of the upper airway and assess airway volume changes before and after transplantation. Before transplantation, two patients presented an exposed naked nasal cavity and two suffered from occlusion of the nasal passage. Two patients required tracheostomy tubes and one had a prosthetic nose. Sleeping disorders were seen in three patients, and chronic cough was diagnosed in one. After transplantation, there was no significant improvement in sleeping disorders. The incidence of sinusitis increased because of mechanical interference of the donor septum and disappeared after surgical correction. All patients were decannulated after transplantation and were capable of nose breathing. Scanning electron micrographs of the respiratory mucosa revealed viable tissue capable of mucin production. Airway volume significantly increased in all patients. Face transplantation successfully restored the upper airway in four patients. Unhindered nasal breathing, viable respiratory mucosa, and a significant increase in airway volume contributed to tracheostomy decannulation.

  1. 21 CFR 870.5150 - Embolectomy catheter.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    .... (a) Identification. An embolectomy catheter is a balloon-tipped catheter that is used to remove thromboemboli, i.e., blood clots which have migrated in blood vessels from one site in the vascular tree to...

  2. Catheter Occlusion in Home Infusion: The Influence of Needleless Connector Design on Central Catheter Occlusion.

    PubMed

    Williams, Ann

    Thrombotic catheter occlusion is a common complication associated with central venous catheters (CVCs). A wide variety of needleless connectors that differ greatly in design and function are available for use with CVCs; however, there are a limited number of studies comparing the catheter occlusion rate associated with differently designed needleless connectors. This retrospective observational study compared occlusion rates associated with a split-septum neutral-displacement needleless connector versus those of a solid-surface neutral-reflux needleless connector in patients undergoing home infusion therapy. The neutral-reflux needleless connector was associated with a significant reduction in occlusion rate and thrombolytic use versus the neutral-displacement needleless connector.

  3. Silicon sensors for catheters and guide wires

    NASA Astrophysics Data System (ADS)

    Goosen, Hans F.

    2001-11-01

    One area that can make use of the miniature size of present day micro electromechanical systems (MEMS) is that of the medical field of minimally invasive interventions. These procedures, used for both diagnosis and treatment, use catheters that are advanced through the blood vessels deep into the body, without the need for surgery. However, once inside the body, the doctor performing the procedure is completely reliant on the information the catheter(s) can provide in addition to the projection imaging of a fluoroscope. A good range of sensors for catheters is required for a proper diagnosis. To this end, miniature sensors are being developed to be fitted to catheters and guide wires. As the accurate positioning of these instruments is problematic, it is necessary to combine several sensors on the same guide wire or catheter to measure several parameters in the same location. This however, brings many special problems to the design of the sensors, such as small size, low power consumption, bio-compatibility of materials, robust design for patient safety, a limited number of connections, packaging, etc. This paper will go into both the advantages and design problems of micromachined sensors and actuators in catheters and guide wires. As an example, a multi parameter blood sensor, measuring flow velocity, pressure and oxygen saturation, will be discussed.

  4. [Combination of the ureteral dilation catheter and balloon catheter under the ureteroscope in the treatment of male urethral stricture].

    PubMed

    Zhou, Yi; Li, Gong-hui; Yan, Jia-jun; Shen, Cong; Tang, Gui-hang; Xu, Gang

    2016-01-01

    To investigate the clinical application of the ureteral dilation catheter combined with the balloon catheter under the ureteroscope in the treatment of urethral stricture in men. Under the ureteroscope, 45 male patients with urethral stricture received placement of a zebra guide wire through the strictured urethra into the bladder and then a ureteral dilation catheter along the guide wire, followed by dilation of the urethra from F8 initially to F14 and F16. Again, the ureteroscope was used to determine the length of the strictured urethra, its distance to the external urethral orifice, and whether it was normally located. An F24 balloon catheter and then a metal urethral calibrator was used for the dilation of the strictured urethra. After removal of the F18-F22 urethral catheter at 8 weeks, the urinary flow rate was measured immediately and again at 3 months. All the operations were successfully performed without serious complications. The maximum urinary flow rate was (13.3-29.9) ml/s (mean [17.7 ± 3.2] ml/s) at the removal of the catheter and (15.2-30.8) ml/s (mean [19.8 ± 3.9] ml/s) at 3 months after it. Smooth urination was found in all the patients during the 6-24 months follow-up. The application of the ureteral dilation catheter combined with, the balloon catheter under the ureteroscope is a good option for the treatment of male urethral stricture for its advantages of uncomplicatedness, safety, effectiveness, few complications, less pain, high success rate, and repeatable operation.

  5. Detection of electrophysiology catheters in noisy fluoroscopy images.

    PubMed

    Franken, Erik; Rongen, Peter; van Almsick, Markus; ter Haar Romeny, Bart

    2006-01-01

    Cardiac catheter ablation is a minimally invasive medical procedure to treat patients with heart rhythm disorders. It is useful to know the positions of the catheters and electrodes during the intervention, e.g. for the automatization of cardiac mapping. Our goal is therefore to develop a robust image analysis method that can detect the catheters in X-ray fluoroscopy images. Our method uses steerable tensor voting in combination with a catheter-specific multi-step extraction algorithm. The evaluation on clinical fluoroscopy images shows that especially the extraction of the catheter tip is successful and that the use of tensor voting accounts for a large increase in performance.

  6. [Quality assurance in airway management: education and training for difficult airway management].

    PubMed

    Kaminoh, Yoshiroh

    2006-01-01

    Respiratory problem is one of the main causes of death or severe brain damage in perioperative period. Three major factors of respiratory problem are esophageal intubation, inadequate ventilation, and difficult airway. The wide spread of pulse oximeter and capnograph reduced the incidences of esophageal intubation and inadequate ventilation, but the difficult airway still occupies the large portion in the causes of adverse events during anesthesia. "Practice guideline for management of the difficult airway" was proposed by American Society of Anesthesiologists (ASA) in 1992 and 2002. Improvement of knowledge, technical skills, and cognitive skills are necessary for the education and training of the difficult airway management. "The practical seminar of difficult airway management (DAM practical seminar)" has been cosponsored by the Japanese Association of Medical Simulation (JAMS) in the 51 st and 52 nd annual meetings of Japanese Society of Anesthesiologists and the 24th annual meeting of Japanese Society for Clinical Anesthesia. The DAM practical seminar is composed of the lecture session for ASA difficult airway algorithm, the hands-on training session for technical skills, and the scenario-based training session for cognitive skills. Ninty six Japanese anesthesiologists have completed the DAM practical seminar in one year. "The DAM instructor course" should be immediately prepared to organize the seminar more frequently.

  7. Design of the exhale airway stents for emphysema (EASE) trial: an endoscopic procedure for reducing hyperinflation

    PubMed Central

    2011-01-01

    Background Airway Bypass is a catheter-based, bronchoscopic procedure in which new passageways are created that bypass the collapsed airways, enabling trapped air to exit the lungs. The Exhale Airway Stents for Emphysema (EASE) Trial was designed to investigate whether Exhale® Drug-Eluting Stents, placed in new passageways in the lungs, can improve pulmonary function and reduce breathlessness in severely hyperinflated, homogeneous emphysema patients (NCT00391612). Methods/Design The multi-center, randomized, double-blind, sham-controlled trial design was posted on http://www.clinicaltrials.gov in October 2006. Because Bayesian statistics are used for the analysis, the proposed enrollment ranged from 225 up to 450 subjects at up to 45 institutions. Inclusion criteria are: high resolution CT scan with evidence of homogeneous emphysema, post-bronchodilator pulmonary function tests showing: a ratio of FEV1/FVC < 70%, FEV1≤50% of predicted or FEV1 < 1 liter, RV/TLC≥0.65 at screening, marked dyspnea score ≥2 on the modified Medical Research Council scale of 0-4, a smoking history of at least 20 pack years and stopped smoking for at least 8 weeks prior to enrollment. Following 16 to 20 supervised pulmonary rehabilitation sessions, subjects were randomized 2:1 to receive either a treatment (Exhale® Drug-Eluting Stent) or a sham bronchoscopy. A responder analysis will evaluate the co-primary endpoints of an FVC improvement ≥12% of the patient baseline value and modified Medical Research Council dyspnea scale improvement (reduction) ≥1 point at the 6-month follow-up visit. Discussion If through the EASE Trial, Airway Bypass is shown to improve pulmonary function and reduce dyspnea while demonstrating an acceptable safety profile, then homogeneous patients will have a minimally invasive treatment option with meaningful clinical benefit. Trial Registration ClinicalTrials.gov: NCT00391612 PMID:21214899

  8. UK Renal Registry 15th annual report: Chapter 8 UK multisite peritoneal dialysis access catheter audit for first PD catheters 2011.

    PubMed

    Briggs, Victoria; Pitcher, David; Braddon, Fiona; Fogarty, Damian; Wilkie, Martin

    2013-01-01

    The central paradigm of effective peritoneal dialysis (PD) is an appropriate standard of PD catheter function. The aim of the project was to develop an effective national PD access audit which would identify an 'appropriate standard' of PD catheter function. The UK Renal Registry collected centre specific information on various PD access outcome measures including catheter functionality and post-insertion complications. The first PD access audit covering England, Northern Ireland and Wales was conducted during April to June 2012 looking at incident dialysis patients in 2011. Forty three data collection spreadsheets were returned from a total of 65 centres describing 917 PD catheter placements. The median age of PD patients was 61 years and 61.5% were male. The proportion of patients initiated on PD in comparison to HD was lower in socially deprived areas. There was a relationship between the timing of nephrology referral and the likelihood of surgical assessment regarding PD catheter placement. Patients with diabetes did not have higher rates of PD catheter failure or of early peritonitis. A comparative PD catheter audit has the potential to provide valuable information on an important patient related outcome measure and lead to an improvement in patient experience. There was wide variation between centres of PD catheter use for late presenting patients. Overall patients were more likely to get a PD catheter if they had been known to the service for more than 1 year. The percutaneous insertion technique was associated with a higher early (less than 2 week) peritonitis rate and more catheter flow problems. Copyright © 2013 S. Karger AG, Basel.

  9. Airway malacia in children with achondroplasia.

    PubMed

    Dessoffy, Kimberly E; Modaff, Peggy; Pauli, Richard M

    2014-02-01

    This study was undertaken to assess the frequency of airway malacia in infants and young children with achondroplasia, a population well known to be at risk for a variety of respiratory problems. We also wished to evaluate what, if any, contribution airway malacia makes to the complex respiratory issues that may be present in those with achondroplasia. Retrospective chart review of all infants and young children with achondroplasia who were assessed through the Midwest Regional Bone Dysplasia Clinics from 1985 through 2012 (n = 236) was completed. Records of comprehensive clinical examinations, polysomnographic assessments, and airway visualization were reviewed and abstracted using a data collection form. Analyses were completed comparing the group with and those without evidence for airway malacia. Thirteen of 236 patients (5.5%) were found to have airway malacia. Most of those affected had lower airway involvement (9/13). The presence of airway malacia was correlated with an increased occurrence of obstructive sleep apnea as well as need for oxygen supplementation, airway surgeries and tracheostomy placement. Although estimates of the frequency of airway malacia in the general population are limited, its frequency in children with achondroplasia appears to be much higher than any published general population estimate. The presence of airway malacia appears to confound other breathing abnormalities in this population and results in the need for more invasive airway treatments. © 2013 Wiley Periodicals, Inc.

  10. Multifunctional catheters combining intracardiac ultrasound imaging and electrophysiology sensing.

    PubMed

    Stephens, D N; Cannata, J; Liu, Ruibin; Zhao, Jian Zhong; Shung, K K; Nguyen, Hien; Chia, R; Dentinger, A; Wildes, D; Thomenius, K E; Mahajan, A; Shivkumar, K; Kim, Kang; O'Donnell, M; Nikoozadeh, A; Oralkan, O; Khuri-Yakub, P T; Sahn, D J

    2008-07-01

    A family of 3 multifunctional intracardiac imaging and electrophysiology (EP) mapping catheters has been in development to help guide diagnostic and therapeutic intracardiac EP procedures. The catheter tip on the first device includes a 7.5 MHz, 64-element, side-looking phased array for high resolution sector scanning. The second device is a forward-looking catheter with a 24-element 14 MHz phased array. Both of these catheters operate on a commercial imaging system with standard software. Multiple EP mapping sensors were mounted as ring electrodes near the arrays for electrocardiographic synchronization of ultrasound images and used for unique integration with EP mapping technologies. To help establish the catheters' ability for integration with EP interventional procedures, tests were performed in vivo in a porcine animal model to demonstrate both useful intracardiac echocardiographic (ICE) visualization and simultaneous 3-D positional information using integrated electroanatomical mapping techniques. The catheters also performed well in high frame rate imaging, color flow imaging, and strain rate imaging of atrial and ventricular structures. The companion paper of this work discusses the catheter design of the side-looking catheter with special attention to acoustic lens design. The third device in development is a 10 MHz forward-looking ring array that is to be mounted at the distal tip of a 9F catheter to permit use of the available catheter lumen for adjunctive therapy tools.

  11. Pigtail catheters used for percutaneous fluid drainage: comparison of performance characteristics.

    PubMed

    Macha, Douglas B; Thomas, John; Nelson, Rendon C

    2006-03-01

    To compare the performance characteristics of various single-lumen all-purpose pigtail drainage catheters. The following parameters were compared: flow rates between catheters of the same size, whether changing the fluid viscosity has any effect on catheter comparisons, the effect on flow of leaving an open three-way stopcock in the drainage pathway, the tendency of the catheters to kink, and catheter patency after kinking, as measured according to flow. All-purpose 8.0-, 8.3-, and 8.5-F (collectively referred to as 8-F); 10.0-, 10.2-, and 10.3-F (collectively referred to as 10-F); and 12.0-F pigtail drainage catheters from three manufacturers were evaluated. Data were compared by using two-tailed t tests after normal distributions were confirmed. P < .05 was considered to represent a significant difference. At comparison of the 8-F catheters, the C.R. Bard catheters demonstrated better flow rates than the Cook and Boston Scientific devices. Among the 10-F catheters, there were no significant differences in the flow rates of fluid with viscosity equivalent to that of water between the C.R. Bard and Boston Scientific catheters; however, both these catheter types demonstrated significantly (P < .05) better flow rates than the Cook devices. Among the 12-F catheters, the C.R. Bard catheters demonstrated significantly (P < .05) better flow rates than the other two catheter types. Changing the fluid viscosity caused no changes in comparison results. In all catheter groups, the presence of a stopcock significantly (P < .05) impaired flow. None of the evaluated catheters demonstrated a clear advantage in terms of patency or susceptibility to kinking. At comparison of the in vitro performances of catheters from different manufacturers, the C.R. Bard 8.0-F and Cook 10.2-F catheters had comparable flow rates, and flow rates through the C.R. Bard and Boston Scientific 10.0-F catheters were comparable to flow rates through the Cook and Boston Scientific 12.0-F catheters

  12. Cryo-balloon catheter localization in fluoroscopic images

    NASA Astrophysics Data System (ADS)

    Kurzendorfer, Tanja; Brost, Alexander; Jakob, Carolin; Mewes, Philip W.; Bourier, Felix; Koch, Martin; Kurzidim, Klaus; Hornegger, Joachim; Strobel, Norbert

    2013-03-01

    Minimally invasive catheter ablation has become the preferred treatment option for atrial fibrillation. Although the standard ablation procedure involves ablation points set by radio-frequency catheters, cryo-balloon catheters have even been reported to be more advantageous in certain cases. As electro-anatomical mapping systems do not support cryo-balloon ablation procedures, X-ray guidance is needed. However, current methods to provide support for cryo-balloon catheters in fluoroscopically guided ablation procedures rely heavily on manual user interaction. To improve this, we propose a first method for automatic cryo-balloon catheter localization in fluoroscopic images based on a blob detection algorithm. Our method is evaluated on 24 clinical images from 17 patients. The method successfully detected the cryoballoon in 22 out of 24 images, yielding a success rate of 91.6 %. The successful localization achieved an accuracy of 1.00 mm +/- 0.44 mm. Even though our methods currently fails in 8.4 % of the images available, it still offers a significant improvement over manual methods. Furthermore, detecting a landmark point along the cryo-balloon catheter can be a very important step for additional post-processing operations.

  13. Extraglottic airway devices: technology update.

    PubMed

    Sharma, Bimla; Sahai, Chand; Sood, Jayashree

    2017-01-01

    Extraglottic airway devices (EADs) have revolutionized the field of airway management. The invention of the laryngeal mask airway was a game changer, and since then, there have been several innovations to improve the EADs in design, functionality, safety and construction material. These have ranged from changes in the shape of the mask, number of cuffs and material used, like rubber, polyvinylchloride and latex. Phthalates, which were added to the construction material in order to increase device flexibility, were later omitted when this chemical was found to have serious adverse reproductive outcomes. The various designs brought out by numerous companies manufacturing EADs resulted in the addition of several devices to the airway market. These airway devices were put to use, many of them with inadequate or no evidence base regarding their efficacy and safety. To reduce the possibility of compromising the safety of the patient, the Difficult Airway Society (DAS) formed the Airway Device Evaluation Project Team (ADEPT) to strengthen the evidence base for airway equipment and vet the new extraglottic devices. A preuse careful analysis of the design and structure may help in better understanding of the functionality of a particular device. In the meantime, the search for the ideal EAD continues.

  14. Double Guiding Catheters for Complex Percutaneous Coronary Intervention

    PubMed Central

    Chou, Shing-Hsien; Lin, Chia-Pin; Lin, Yen-Chen; Kuo, Chi-Tai; Lin, Ming-Shyan; Chang, Chi-Jen

    2012-01-01

    A large-lumen guiding catheter is often used for complex percutaneous coronary intervention—particularly when a final kissing-balloon or 2-stent technique is required. However, catheter insertion is sometimes restricted by diseased vascular access sites or a tortuous vascular route. We report 2 cases in which a unique double guiding catheter technique was used to create a lumen of sufficient size for complex percutaneous coronary intervention. In each patient, two 6F guiding catheters were used concurrently to engage the ostium of 1 target vessel. In 1 patient, these catheters were used for the delivery of 2 balloons to complete kissing-balloon dilation after single-stent placement. In the other patient, the catheters were used to deliver 2 stents sequentially to their respective target lesions. The stents were then deployed simultaneously as kissing stents, followed by high-pressure kissing-balloon postdilation. PMID:22412243

  15. Endoscopic-Assisted Burr Hole Reservoir and Ventricle Catheter Placement.

    PubMed

    Antes, Sebastian; Tschan, Christoph A; Heckelmann, Michael; Salah, Mohamed; Senger, Sebastian; Linsler, Stefan; Oertel, Joachim

    2017-05-01

    Accurate positioning of a ventricle catheter is of utmost importance. Various techniques to ensure optimal positioning have been described. Commonly, after catheter placement, additional manipulation is necessary to connect a burr hole reservoir or shunt components. This manipulation can lead to accidental catheter dislocation and should be avoided. Here, we present a new technique that allows direct endoscopic insertion of a burr hole reservoir with an already mounted ventricle catheter. Before insertion, the ventricle catheter was slit at the tip, shortened to the correct length, and connected to the special burr hole reservoir. An intracatheter endoscope was then advanced through the reservoir and the connected catheter. This assemblage allowed using the endoscope as a stylet for shielded ventricular puncture. To confirm correct placement of the ventricle catheter, the endoscope was protruded a few millimeters beyond the catheter tip for inspection. The new technique was applied in 12 procedures. The modified burr hole reservoir was inserted for first-time ventriculoperitoneal shunting (n = 1), cerebrospinal fluid withdrawals and drug administration (n = 2), or different stenting procedures (n = 9). Optimal positioning of the catheter was achieved in 11 of 12 cases. No subcutaneous cerebrospinal fluid collection or fluid leakage through the wound occurred. No parenchymal damage or bleeding appeared. The use of the intracatheter endoscope combined with the modified burr hole reservoir provides a sufficient technique for accurate and safe placement. Connecting the ventricle catheter to the reservoir before the insertion reduces later manipulation and accidental dislocation of the catheter. Copyright © 2017 Elsevier Inc. All rights reserved.

  16. Baclofen pump catheter leakage after migration of the abdominal catheter in a pediatric patient with spasticity.

    PubMed

    Dastgir, Amer; Ranalli, Nathan J; MacGregor, Theresa L; Aldana, Philipp R

    2015-09-01

    The authors report an unusual case of intrathecal baclofen withdrawal due to the perforation and subsequent leakage of a baclofen pump catheter in a patient with spastic cerebral palsy. A 15-year-old boy underwent an uncomplicated placement of an intrathecal baclofen pump for the treatment of spasticity due to cerebral palsy. After excellent control of symptoms for 3 years, the patient presented to the emergency department with increasing tremors following a refill of his baclofen pump. Initial evaluation consisted of radiographs of the pump and catheter, which appeared normal, and a successful aspiration of CSF from the pump's side port. A CT dye study revealed a portion of the catheter directly overlying the refill port and extravasation of radiopaque dye into the subfascial pocket anterior to the pump. During subsequent revision surgery, a small puncture hole in the catheter was seen to be leaking the drug. The likely cause of the puncture was an inadvertent perforation of the catheter by a needle during the refilling of the pump. This case report highlights a unique complication in a patient with an intrathecal baclofen pump. Physicians caring for these patients should be aware of this rare yet potential complication in patients presenting with baclofen withdrawal symptoms.

  17. Airway Protective Mechanisms

    PubMed Central

    Pitts, Teresa

    2014-01-01

    Cough and swallow are highly coordinated reflex behaviors whose common purpose is to protect the airway. The pharynx is the common tube for air and food/liquid movement from the mouth into the thorax, has been largely overlooked, and is potentially seen as just a passive space. The thyropharyngeus muscle responds to cough inducing stimuli to prepare a transient holding area for material that has been removed from the subglottic airway. The cricopharyngeus muscle participates with the larynx to ensure regulation of pressure when a bolus/air is moving from the upper airway through to the thorax (i.e inspiration or swallow) or the reverse (i.e expiration reflex or vomiting).These vital mechanisms have not been evaluated in clinical conditions, but could be impaired in many neurodegenerative diseases leading to aspiration pneumonia. These newly described airway protective mechanisms need further study, especially in healthy and pathologic human populations. PMID:24297325

  18. Balloon catheter versus basket catheter for endoscopic bile duct stone extraction: a multicenter randomized trial.

    PubMed

    Ishiwatari, Hirotoshi; Kawakami, Hiroshi; Hisai, Hiroyuki; Yane, Kei; Onodera, Manabu; Eto, Kazunori; Haba, Shin; Okuda, Toshinori; Ihara, Hideyuki; Kukitsu, Takehiro; Matsumoto, Ryusuke; Kitaoka, Keisuke; Sonoda, Tomoko; Hayashi, Tsuyoshi

    2016-04-01

    Endoscopic bile duct stone (BDS) removal is a well-established treatment; however, the preference for basket or balloon catheters for extraction is operator-dependent. We therefore conducted a multicenter prospective randomized trial to compare catheter performance. We enrolled patients with a BDS diameter ≤ 10 mm and common bile duct diameter ≤ 15 mm. Participants were randomly assigned to groups that were treated with basket or balloon catheters between October 2013 and September 2014. The primary endpoint was the rate of complete clearance of the duct; the secondary endpoints were the rate and time to complete clearance in one endoscopic session. We initially enrolled 172 consecutive patients; 14 were excluded after randomization. The complete clearance rates were 92.3 % (72/78) in the balloon group and 80.0 % (64 /80) in the basket group. The difference in the rates between the two groups was 12.3 percentage points, indicating non-inferiority of the balloon method (non-inferiority limit -10 %; P < 0.001 for non-inferiority). Moreover, the balloon was superior to the basket (P = 0.037). The rate of complete clearance in one endoscopic session was 97.4 % using the balloon and 97.5 % using the basket (P = 1.00). The median times to complete clearance in one endoscopic session were 6.0 minutes (1 - 30) and 7.8 minutes (1 - 37) in the balloon and basket groups, respectively (P = 0.15). For extraction of BDSs ≤ 10 mm, complete endoscopic treatment with a single catheter is more likely when choosing a balloon catheter over a basket catheter.University Hospital Medical Information Network Trials Registry: UMIN000011887. © Georg Thieme Verlag KG Stuttgart · New York.

  19. Bacteria on catheters in patients undergoing peritoneal dialysis.

    PubMed

    Pihl, Maria; Davies, Julia R; Johansson, Ann-Cathrine; Svensäter, Gunnel

    2013-01-01

    Peritonitis is the leading cause of morbidity for peritoneal dialysis (PD) patients, and microbial biofilms have previously been identified on catheters from infected patients. However, few studies of catheters from patients without clinical signs of infection have been undertaken. The aim of the present study was to investigate the extent to which bacteria are present on catheters from PD patients with no symptoms of infection. Microbiologic culturing under aerobic and anaerobic conditions and confocal laser scanning microscopy were used to determine the distribution of bacteria on PD catheters from 15 patients without clinical signs of infection and on catheters from 2 infected patients. The 16S rRNA gene sequencing technique was used to identify cultured bacteria. Bacteria were detected on 12 of the 15 catheters from patients without signs of infection and on the 2 catheters from infected patients. Single-species and mixed-microbial communities containing up to 5 species were present on both the inside and the outside along the whole length of the colonized catheters. The bacterial species most commonly found were the skin commensals Staphylococcus epidermidis and Propionibacterium acnes, followed by S. warneri and S. lugdunensis. The strains of these micro-organisms, particularly those of S. epidermidis, varied in phenotype with respect to their tolerance of the major classes of antibiotics. Bacteria were common on catheters from patients without symptoms of infection. Up to 4 different bacterial species were found in close association and may represent a risk factor for the future development of peritonitis in patients hosting such micro-organisms.

  20. Magnetic Catheter Manipulation in the Interventional MRI Environment

    PubMed Central

    Wilson, Mark W.; Martin, Alastair B.; Lillaney, Prasheel; Losey, Aaron D.; Yee, Erin J.; Bernhardt, Anthony; Malba, Vincent; Evans, Lee; Sincic, Ryan; Saeed, Maythem; Arenson, Ronald L.; Hetts, Steven W.

    2013-01-01

    Purpose To evaluate deflection capability of a prototype endovascular catheter, which is remotely magnetically steerable, for use in the interventional MRI environment. Materials and Methods Copper coils were mounted on the tips of commercially available 2.3 – 3.0 Fr microcatheters. The coils were fabricated in a novel manner by plasma vapor deposition of a copper layer followed by laser lithography of the layer into coils. Orthogonal helical (solenoid) and saddle-shaped (Helmholtz) coils were mounted on a single catheter tip. Microcatheters were tested in water bath phantoms in a 1.5T clinical MRI scanner, with variable simultaneous currents applied to the coils. Catheter tip deflection was imaged in the axial plane utilizing a “real-time” steady-state free precession (SSFP) MRI sequence. Degree of deflection and catheter tip orientation were measured for each current application. Results The catheter tip was clearly visible in the longitudinal and axial planes. Magnetic field artifacts were visible when the orthogonal coils at the catheter tip were energized. Variable amounts of current applied to a single coil demonstrated consistent catheter deflection in all water bath experiments. Changing current polarity reversed the observed direction of deflection, whereas current applied to two different coils resulted in deflection represented by the composite vector of individual coil activations. Microcatheter navigation through the vascular phantom was successful through control of applied current to one or more coils. Conclusion Controlled catheter deflection is possible with laser lithographed multi-axis coil tipped catheters in the MRI environment. PMID:23707097

  1. The effect of body weight on distal airway function and airway inflammation.

    PubMed

    van de Kant, Kim D G; Paredi, Paolo; Meah, Sally; Kalsi, Harpal S; Barnes, Peter J; Usmani, Omar S

    Obesity is a global health problem that adversely influences the respiratory system. We assessed the effects of body mass index (BMI) on distal airway function and airway inflammation. Impulse oscillometry (IOS) as a measure of distal airway function, together with spirometry, were assessed in adults with a range of different BMIs. Airway inflammation was assessed with the fraction of exhaled nitric oxide (FeNO) and participants exhaled at various exhalation flows to determine alveolar and bronchial NO. In total 34 subjects were enrolled in the study; 19 subjects had a normal BMI (18.50-24.99), whilst 15 subjects were overweight (BMI 25.00-29.99), or obese (BMI ≥30). All subjects had normal spirometry. However, IOS measures of airway resistance (R) at 5Hz, 20Hz and frequency dependence (R 5-20 ) were elevated in overweight/obese individuals, compared to subjects with a normal BMI (median (interquartile range)); 5Hz: 0.41 (0.37, 0.45) vs. 0.32 (0.30, 0.37)kPa/l/s; 20Hz: 0.34 (0.30, 0.37) vs. 0.30 (0.26, 0.33)kPa/l/s; R 5-20 : 0.06 (0.04, 0.11) vs. 0.03 (0.01, 0.05)kPa/l/s; p<0.05), whereas airway reactance at 20Hz was decreased in overweight/obese individuals (20Hz: 0.07 (0.03, 0.09) vs. 0.10 (0.07, 0.13)kPa/l/s, p=0.009; 5Hz: -0.12 (-0.15, -0.10) vs. -0.10 (-0.13, -0.09)kPa/l/s, p=0.07). In contrast, within-breath IOS measures (a sign of expiratory flow limitation) and FeNO inflammatory measures, did not differ between groups (p>0.05). Being overweight has significant effects on distal and central airway function as determined by IOS, which is not detected by spirometry. Obesity does not influence airway inflammation as measured by FeNO. IOS is a reliable technique to identify airway abnormalities in the presence of normal spirometry in overweight people. Copyright © 2015 Asia Oceania Association for the Study of Obesity. Published by Elsevier Ltd. All rights reserved.

  2. 21 CFR 870.1290 - Steerable catheter control system.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Steerable catheter control system. 870.1290... (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1290 Steerable catheter control system. (a) Identification. A steerable catheter control system is a device that is...

  3. 21 CFR 870.1290 - Steerable catheter control system.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Steerable catheter control system. 870.1290... (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1290 Steerable catheter control system. (a) Identification. A steerable catheter control system is a device that is...

  4. 21 CFR 870.1290 - Steerable catheter control system.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Steerable catheter control system. 870.1290... (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1290 Steerable catheter control system. (a) Identification. A steerable catheter control system is a device that is...

  5. Percutaneous transfemoral repositioning of malpositioned central venous catheters.

    PubMed

    Hartnell, G G; Roizental, M

    1995-04-01

    Central venous catheters inserted by blind surgical placement may not advance into a satisfactory position and may require repositioning. Malpositioning via surgical insertion is common in patients in whom central venous catheters have previously been placed, as these patients are more likely to have central venous thrombosis and distortion of central venous anatomy. This is less of a problem when catheter placement is guided by imaging; however, even when insertion is satisfactory, central venous catheters may become displaced spontaneously after insertion (Fig. 1). Repositioning can be effected by direct manipulation using guidewires or tip-deflecting wires [1, 2], by manipulation via a transfemoral venous approach [3-5], and by injection of contrast material or saline [6]. Limitations of the direct approach include (1) the number and type of maneuvers that can be performed to effect repositioning when anatomy is distorted, (2) difficulty in accessing the catheter, and (3) the risk of introducing infection. Moreover, these patients are often immunosuppressed, and there is a risk of introducing infection by exposing and directly manipulating the venous catheter. Vigorous injection of contrast material or saline may be unsuccessful for the same reasons: It seldom exerts sufficient force to reposition large-caliber central venous catheters and may cause vessel damage or rupture if injection is made into a small or thrombosed vessel. We illustrate several alternative methods for catheter repositioning via a transfemoral venous approach.

  6. A prospective interventional study to examine the effect of a silver alloy and hydrogel-coated catheter on the incidence of catheter-associated urinary tract infection.

    PubMed

    Chung, P Hy; Wong, C Wy; Lai, C Kc; Siu, H K; Tsang, D Nc; Yeung, K Y; Ip, D Km; Tam, P Kh

    2017-06-01

    Catheter-associated urinary tract infection is a major hospital-acquired infection. This study aimed to analyse the effect of a silver alloy and hydrogel-coated catheter on the occurrence of catheter-associated urinary tract infection. This was a 1-year prospective study conducted at a single centre in Hong Kong. Adult patients with an indwelling urinary catheter for longer than 24 hours were recruited. The incidence of catheter-associated urinary tract infection in patients with a conventional latex Foley catheter without hydrogel was compared with that in patients with a silver alloy and hydrogel-coated catheter. The most recent definition of urinary tract infection was based on the latest surveillance definition of the National Healthcare Safety Network managed by Centers for Disease Control and Prevention. A total of 306 patients were recruited with a similar ratio between males and females. The mean (standard deviation) age was 81.1 (10.5) years. The total numbers of catheter-days were 4352 and 7474 in the silver-coated and conventional groups, respectively. The incidences of catheter-associated urinary tract infection per 1000 catheter-days were 6.4 and 9.4, respectively (P=0.095). There was a 31% reduction in the incidence of catheter-associated urinary tract infection per 1000 catheter-days in the silver-coated group. Escherichia coli was the most commonly involved pathogen (36.7%) of all cases. Subgroup analysis revealed that the protective effect of silver-coated catheter was more pronounced in long-term users as well as female patients with a respective 48% (P=0.027) and 42% (P=0.108) reduction in incidence of catheter-associated urinary tract infection. The mean catheterisation time per person was the longest in patients using a silver-coated catheter (17.0 days) compared with those using a conventional (10.8 days) or both types of catheter (13.6 days) [P=0.01]. Silver alloy and hydrogel-coated catheters appear to be effective in preventing catheter

  7. Catheter placement for lysis of spontaneous intracerebral hematomas: is a navigated stylet better than pointer-guided frameless stereotaxy for intrahematomal catheter positioning?

    PubMed

    Malinova, Vesna; Stockhammer, Florian; Atangana, Etienne Ndzie; Mielke, Dorothee; Rohde, Veit

    2014-06-01

    The optimal management of spontaneous intracerebral hemorrhage (ICH), especially if deep-seated, remains a matter of discussion. Lysis of the blood clot applying recombinant tissue-type plasminogen activator (rtPA) by an intrahematomal catheter is a minimally invasive treatment option, currently being under investigation in a randomized trial. The center position of the catheter in the hematoma is believed to be crucial for an optimal clot lysis. To achieve this objective, frame-based stereotaxy and frameless stereotaxy with guidance of an articulated arm were used. Recently, a preregistered stylet for direct navigation, alleviating the need of guidance, became available. In this study, we evaluated the relative error (RE) describing the deviation of the catheter from the ideal center position in the clot and compared the accuracy of catheter placement using frameless stereotaxy or the novel preregistered stylet. The intrahematomal catheter position was evaluated in three dimensions in 89 patients with spontaneous supratentorial ICH. Frameless stereotaxy with guidance of an articulated arm was performed in 50 patients. The preregistered stylet was used in 39 patients. The catheter position was evaluated using a RE calculating the distance perpendicular to the center of the catheter in relation to the hematoma's diameter. The mean hematoma volume was 51.4 ml. Forty-four out of 89 hematomas were deep-seated. Intraventricular blood was found in 59 patients. The RE of the catheter position was lower in the stylet group in comparison to the frameless stereotaxy group (mean 0.57 vs. 0.90; p = 0.0018). There was no difference between deep-seated and lobar hematomas with regard to the accuracy of catheter placement (p = 0.62). The RE is a robust measure for describing intrahematomal catheter position. The preregistered stylet facilitates a satisfactory catheter placement and is a viable alternative to frameless stereotaxy and guidance with the articulated arm.

  8. [Incidence and risk factors for infections from hemodialysis catheters].

    PubMed

    Jean, G

    2001-01-01

    We report here a revue of hemodialysis catheter-related infections data published since 1985. The reported prevalence of bacteremia is 1 to 20% of catheters, and incidence is 0.72 to 9/1000 catheter-days. Local infection is reported in 6 to 63% of catheters and in 1 to 5/1000 catheter-days. Tunneled catheters and implantables chambers reported less infection rate. The most severe complication is endocarditis (4% rate). Death occurs in 8 to 20% of cases. Reported microbial data show that Staphylococcus aureus (SA) is responsible for most infections ahead of non-aureus Staphylococcus. SA skin colonisation is a risk factor for catheter colonisation and the first step of infection. On the other hand, the host immunity impairment in hemodialysis patients seems a significant risk factor. Iron overload, specially after blood transfusions, older age, diabetes mellitus, low serum albumin level, previous history of bacteremia and immunosuppressive treatment have been frequently involved. Other catheter-related factors are time of use, absence of tunnel and use for parenteral nutrition. Nurses plans, dressing type and frequency, nurses work experience are also important. In spite of recent progress in risk factor understanding, hemodialysis-related infection remains frequent. Multicentre studies are necessary to better evaluated care protocols and new catheter material.

  9. Exploring the context of the lung proteome within the airway mucosa following allergen challenge.

    PubMed

    Fehniger, Thomas E; Sato-Folatre, José-Gabriel; Malmström, Johan; Berglund, Magnus; Lindberg, Claes; Brange, Charlotte; Lindberg, Henrik; Marko-Varga, György

    2004-01-01

    The lung proteome is a dynamic collection of specialized proteins related to pulmonary function. Many cells of different derivations, activation states, and levels of maturity contribute to the changing environment, which produces the lung proteome. Inflammatory cells reacting to environmental challenge, for example from allergens, produce and secrete proteins which have profound effects on both resident and nonresident cells located in airways, alveoli, and the vascular tree which provides blood cells to the parenchyma alveolar bed for gas exchange. In an experimental model of allergic airway inflammation, we have compared control and allergen challenged lung compartments to determine global protein expression patterns using 2D-gel electrophoresis and subsequent spot identification by MS/MS mass spectrometry. We have then specifically isolated the epithelial mucosal layer, which lines conducting airways, from control and allergen challenged lungs, using laser capture technology and performed proteome identification on these selected cell samples. A central component of our investigations has been to contextually relate the histological features of the dynamic pulmonary environment to the changes in protein expression observed following challenge. Our results provide new information of the complexity of the submucosa/epithelium interface and the mechanisms behind the transformation of airway epithelium from normal steady states to functionally activated states.

  10. [Application of injection test in confirming the ideal position of esophageal balloon catheter].

    PubMed

    Chen, Han; Xu, Ming; Yang, Yanlin; He, Xuan; Zhou, Jianxin

    2017-09-01

    To evaluate the safety and feasibility of injection test which is used to locate esophageal balloon catheter. A prospective study was conducted. The patients undergoing invasive mechanical ventilation (MV) admitted to general intensive care unit (ICU) of Beijing Tiantan Hospital Affiliated to Capital Medical University from May 2015 and March 2017 were enrolled. The commercially available esophageal balloon catheter was modified to perform injection test. The catheter was withdrawn step by step and the injection test was repeated until the presence disturbance wave presented, which indicated that the balloon had just entered the esophagus. The position where disturbance wave appears was named 0 cm. End-expiratory occlusions were performed at the positions of +15, +10, +5, 0, -5, -10 and -15 cm, respectively, and the changes of esophageal pressure (Pes) and airway pressures (Paw) were measured in the spontaneous breathing and passive ventilation, and the ratio between the changes (ΔPes/ΔPaw) was calculated. A total of 20 patients were enrolled, of which 15 patients finished both the spontaneous and the passive ventilation parts, and 2 patients finished only the spontaneous part and 3 patients finished only passive part. (1) Disturbance waves could be induced by injection test in all patients. The average depth of disturbance wave in spontaneous breathing was deeper than that in passive ventilation (cm: 42.4±3.8 vs. 41.8±3.3), but there was no significant difference between the two ventilation settings (P = 0.132). No adverse events occurred during the study period. (2) Pes increased with the stepwise withdraw of esophageal catheter, reached the maximal value at +5 cm, and then decreased when the catheter was further withdrawn, no matter in the spontaneous or the passive ventilation. In spontaneous breathing, the ΔPes/ΔPaw was within the ideal range (0.8-1.2) at the positions of 0, -5 and -10 cm. The ΔPes/ΔPaw was closest to unity at the positions of 0 cm (0

  11. Definitive airway management after pre-hospital supraglottic airway insertion: Outcomes and a management algorithm for trauma patients.

    PubMed

    Hernandez, Matthew C; Aho, Johnathon M; Zielinski, Martin D; Zietlow, Scott P; Kim, Brian D; Morris, David S

    2018-01-01

    Prehospital airway management increasingly involves supraglottic airway insertion and a paucity of data evaluates outcomes in trauma populations. We aim to describe definitive airway management in traumatically injured patients who necessitated prehospital supraglottic airway insertion. We performed a single institution retrospective review of multisystem injured patients (≥15years) that received prehospital supraglottic airway insertion during 2009 to 2016. Baseline demographics, number and type of: supraglottic airway insertion attempts, definitive airway and complications were recorded. Primary outcome was need for tracheostomy. Univariate and multivariable statistics were performed. 56 patients met inclusion criteria and were reviewed, 78% were male. Median age [IQR] was 36 [24-56] years. Injuries comprised blunt (94%), penetrating (4%) and burns (2%). Median ISS was 26 [22-41]. Median number of prehospital endotracheal intubation (PETI) attempts was 2 [1-3]. Definitive airway management included: (n=20, 36%, tracheostomy), (n=10, 18%, direct laryngoscopy), (n=6, 11%, bougie), (n=9, 15%, Glidescope), (n=11, 20%, bronchoscopic assistance). 24-hour mortality was 41%. Increasing number of PETI was associated with increasing facial injury. On regression, increasing cervical and facial injury patterns as well as number of PETI were associated with definitive airway control via surgical tracheostomy. After supraglottic airway insertion, operative or non-operative approaches can be utilized to obtain a definitive airway. Patients with increased craniofacial injuries have an increased risk for airway complications and need for tracheostomy. We used these factors to generate an evidence based algorithm that requires prospective validation. Level IV - Retrospective study. Retrospective single institution study. Copyright © 2017 Elsevier Inc. All rights reserved.

  12. Airway compliance and dynamics explain the apparent discrepancy in length adaptation between intact airways and smooth muscle strips.

    PubMed

    Dowie, Jackson; Ansell, Thomas K; Noble, Peter B; Donovan, Graham M

    2016-01-01

    Length adaptation is a phenomenon observed in airway smooth muscle (ASM) wherein over time there is a shift in the length-tension curve. There is potential for length adaptation to play an important role in airway constriction and airway hyper-responsiveness in asthma. Recent results by Ansell et al., 2015 (JAP 2014 10.1152/japplphysiol.00724.2014) have cast doubt on this role by testing for length adaptation using an intact airway preparation, rather than strips of ASM. Using this technique they found no evidence for length adaptation in intact airways. Here we attempt to resolve this apparent discrepancy by constructing a minimal mathematical model of the intact airway, including ASM which follows the classic length-tension curve and undergoes length adaptation. This allows us to show that (1) no evidence of length adaptation should be expected in large, cartilaginous, intact airways; (2) even in highly compliant peripheral airways, or at more compliant regions of the pressure-volume curve of large airways, the effect of length adaptation would be modest and at best marginally detectable in intact airways; (3) the key parameters which control the appearance of length adaptation in intact airways are airway compliance and the relaxation timescale. The results of this mathematical simulation suggest that length adaptation observed at the level of the isolated ASM may not clearly manifest in the normal intact airway. Copyright © 2015 Elsevier B.V. All rights reserved.

  13. 21 CFR 876.4020 - Fiberoptic light ureteral catheter.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Fiberoptic light ureteral catheter. 876.4020... (CONTINUED) MEDICAL DEVICES GASTROENTEROLOGY-UROLOGY DEVICES Surgical Devices § 876.4020 Fiberoptic light ureteral catheter. (a) Identification. A fiberoptic light ureteral catheter is a device that consists of a...

  14. 21 CFR 876.4020 - Fiberoptic light ureteral catheter.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Fiberoptic light ureteral catheter. 876.4020... (CONTINUED) MEDICAL DEVICES GASTROENTEROLOGY-UROLOGY DEVICES Surgical Devices § 876.4020 Fiberoptic light ureteral catheter. (a) Identification. A fiberoptic light ureteral catheter is a device that consists of a...

  15. 21 CFR 876.4020 - Fiberoptic light ureteral catheter.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Fiberoptic light ureteral catheter. 876.4020... (CONTINUED) MEDICAL DEVICES GASTROENTEROLOGY-UROLOGY DEVICES Surgical Devices § 876.4020 Fiberoptic light ureteral catheter. (a) Identification. A fiberoptic light ureteral catheter is a device that consists of a...

  16. 21 CFR 876.4020 - Fiberoptic light ureteral catheter.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Fiberoptic light ureteral catheter. 876.4020... (CONTINUED) MEDICAL DEVICES GASTROENTEROLOGY-UROLOGY DEVICES Surgical Devices § 876.4020 Fiberoptic light ureteral catheter. (a) Identification. A fiberoptic light ureteral catheter is a device that consists of a...

  17. Antifungal catheter lock therapy for the management of a persistent Candida albicans bloodstream infection in an adult receiving hemodialysis.

    PubMed

    Paul DiMondi, V; Townsend, Mary L; Johnson, Melissa; Durkin, Michael

    2014-07-01

    Antifungal catheter lock therapy (AfLT) with liposomal amphotericin B has been used in the treatment of pediatric central line infections caused by Candida species; however, reports describing the use of liposomal amphotericin B lock therapy in the adult hemodialysis patient population are lacking. Management of central line-associated candidemia with systemic therapy alone is often challenging due to the propensity of Candida species to form biofilms on foreign bodies. We describe a 64-year-old woman who was receiving hemodialysis 3 times/week and was hospitalized with persistent fungemia. Despite receiving intravenous micafungin, she had multiple positive blood cultures for Candida albicans, which finally cleared after 7 days. Her double-lumen catheter was considered the most likely nidus of infection. Although catheter removal would have been preferred, this was not possible given her vasculopathy, history of multiple bloodstream infections, and lack of other available sites for vascular access. Catheter exchange was performed, and liposomal amphotericin B AfLT was administered in combination with intravenous micafungin for a total of 6 days. During this time, the patient experienced no discernible adverse effects secondary to AfLT. At discharge, AfLT was discontinued, and intravenous micafungin was changed to oral fluconazole. After 6 months of treatment, the patient remained culture negative and maintained her dialysis access. To our knowledge, this is the first case report of liposomal amphotericin B catheter lock therapy used to manage a persistent C. albicans bloodstream infection in an adult receiving hemodialysis. AfLT is a novel concept for treating catheter-associated fungal infections. Liposomal amphotericin B was chosen based on its favorable in vitro activity against Candida species biofilms in catheter lock environments. We identified several barriers to implementing AfLT, and these issues may prohibit the use of AfLT. This case report

  18. Biophysics and pathology of catheter energy delivery systems.

    PubMed

    Nath, S; Haines, D E

    1995-01-01

    Catheter ablation has rapidly emerged as the treatment of choice for many symptomatic cardiac arrhythmias. The initial experience with catheter ablation used high-energy DC as the energy source. However, over the last several years radiofrequency (RF) catheter ablation has become the dominant mode of energy delivery. Currently, a major limitation of RF ablation is the small lesion size created by this technique that has reduced its success rate in ablation of larger arrhythmogenic substrates such as coronary artery disease-related ventricular tachycardia. Alternate energy sources such as microwave or ultrasound catheter ablation are being developed that have the potential for producing larger lesions than RF ablation. This review will discuss the biophysics and pathophysiology of the various energy modalities used in catheter ablation.

  19. Pacing threshold changes after transvenous catheter countershock.

    PubMed

    Yee, R; Jones, D L; Klein, G J

    1984-02-01

    The serial changes in pacing threshold and R-wave amplitude were examined after insertion of a countershock catheter in 12 patients referred for management of recurrent ventricular tachyarrhythmias. In 6 patients, values before and immediately after catheter countershock were monitored. Pacing threshold increased (from 1.4 +/- 0.2 to 2.4 +/- 0.5 V, mean +/- standard error of the mean, p less than 0.05) while the R-wave amplitude decreased (bipolar R wave from 5.9 +/- 1.1 to 3.4 +/- 0.7 mV, p less than 0.01; unipolar R wave recorded from the distal ventricular electrode from 8.9 +/- 1.8 to 4.6 +/- 1.2 mV, p less than 0.01; and proximal ventricular electrode from 7.7 +/- 1.5 to 5.0 +/- 1.0 mV, p less than 0.01). A return to control values occurred within 10 minutes. In all patients, pacing threshold increased by 154 +/- 30% (p less than 0.001) during the first 7 days that the catheter was in place. It is concluded that catheter countershock causes an acute increase in pacing threshold and decrease in R-wave amplitude. A catheter used for countershock may not be acceptable as a backup pacing catheter.

  20. Critical Airway Team: A Retrospective Study of an Airway Response System in a Pediatric Hospital.

    PubMed

    Sterrett, Emily C; Myer, Charles M; Oehler, Jennifer; Das, Bobby; Kerrey, Benjamin T

    2017-12-01

    Objective Study the performance of a pediatric critical airway response team. Study Design Case series with chart review. Setting Freestanding academic children's hospital. Subjects and Methods A structured review of the electronic medical record was conducted for all activations of the critical airway team. Characteristics of the activations and patients are reported using descriptive statistics. Activation of the critical airway team occurred 196 times in 46 months (March 2012 to December 2015); complete data were available for 162 activations (83%). For 49 activations (30%), patients had diagnoses associated with difficult intubation; 45 (28%) had a history of difficult laryngoscopy. Results Activation occurred at least 4 times per month on average (vs 3 per month for hospital-wide codes). The most common reasons for team activation were anticipated difficult intubation (45%) or failed intubation attempt (20%). For 79% of activations, the team performed an airway procedure, most commonly direct laryngoscopy and tracheal intubation. Bronchoscopy was performed in 47% of activations. Surgical airway rescue was attempted 4 times. Cardiopulmonary resuscitation occurred in 41 activations (25%). Twenty-nine patients died during or following team activation (18%), including 10 deaths associated with the critical airway event. Conclusion Critical airway team activation occurred at least once per week on average. Direct laryngoscopy, tracheal intubation, and bronchoscopic procedures were performed frequently; surgical airway rescue was rare. Most patients had existing risk factors for difficult intubation. Given our rate of serious morbidity and mortality, primary prevention of critical airway events will be a focus of future efforts.

  1. [Periinterventional prophylactic antibiotics in radiological port catheter implantation].

    PubMed

    Gebauer, B; Teichgräber, U; Werk, M; Wagner, H-J

    2007-08-01

    To evaluate whether catheter-related infections after radiologically placed port catheters can be reduced by single-shot periinterventional antibiosis. Between January and September 2002, 164 consecutive patients with indication for central venous port catheter implantation were included in the present study. During implantation the interventional radiologist was responsible for deciding whether to administer a prophylactic single-shot antibiosis. The prophylactic antibiosis entailed intravenous administration of ampicillin and sulbactam (3 g Unacid, Pfizer) or 100 mg ciprofloxacine (Ciprobay, Bayer) in the case of an allergy history to penicillins. Catheter-related infection was defined as a local or systemic infection necessitating port catheter extraction. Indication for port catheter implantation was a malignant disease requiring chemotherapy in 158 cases. The port catheter (Chemosite [Tyco Healthcare] [n = 123], low-profile [Arrow International] [n = 35], other port system [n = 6]) was implanted via sonographically guided puncture of the right jugular vein in 139 patients, via the left jugular vein in 24 cases and via the right subclavian vein in one patient. 75 patients received periinterventional prophylactic antibiosis (Unacid [n = 63] Ciprobay [n = 12]) and 89 patients did not receive antibiosis. The prophylactic antibiosis caused a minor allergic reaction in one patient that improved with antihistamic and corticoid medication. A total of 7 ports, 6 without prophylactic antibiosis versus one with periinterventional prophylaxis, were extracted due to infectious complications. Single-shot periinterventional prophylactic antibiosis can reduce early and late infectious complications after radiological-interventional placement of central venous port catheters.

  2. All India Difficult Airway Association 2016 guidelines for the management of unanticipated difficult tracheal intubation in adults.

    PubMed

    Myatra, Sheila Nainan; Shah, Amit; Kundra, Pankaj; Patwa, Apeksh; Ramkumar, Venkateswaran; Divatia, Jigeeshu Vasishtha; Raveendra, Ubaradka S; Shetty, Sumalatha Radhakrishna; Ahmed, Syed Moied; Doctor, Jeson Rajan; Pawar, Dilip K; Ramesh, Singaravelu; Das, Sabyasachi; Garg, Rakesh

    2016-12-01

    The All India Difficult Airway Association (AIDAA) guidelines for management of the unanticipated difficult airway in adults provide a structured, stepwise approach to manage unanticipated difficulty during tracheal intubation in adults. They have been developed based on the available evidence; wherever robust evidence was lacking, or to suit the needs and situation in India, recommendations were arrived at by consensus opinion of airway experts, incorporating the responses to a questionnaire sent to members of the AIDAA and the Indian Society of Anaesthesiologists. We recommend optimum pre-oxygenation and nasal insufflation of 15 L/min oxygen during apnoea in all patients, and calling for help if the initial attempt at intubation is unsuccessful. Transnasal humidified rapid insufflations of oxygen at 70 L/min (transnasal humidified rapid insufflation ventilatory exchange) should be used when available. We recommend no more than three attempts at tracheal intubation and two attempts at supraglottic airway device (SAD) insertion if intubation fails, provided oxygen saturation remains ≥ 95%. Intubation should be confirmed by capnography. Blind tracheal intubation through the SAD is not recommended. If SAD insertion fails, one final attempt at mask ventilation should be tried after ensuring neuromuscular blockade using the optimal technique for mask ventilation. Failure to intubate the trachea as well as an inability to ventilate the lungs by face mask and SAD constitutes 'complete ventilation failure', and emergency cricothyroidotomy should be performed. Patient counselling, documentation and standard reporting of the airway difficulty using a 'difficult airway alert form' must be done. In addition, the AIDAA provides suggestions for the contents of a difficult airway cart.

  3. A 4-Week Model of House Dust Mite (HDM) Induced Allergic Airways Inflammation with Airway Remodeling.

    PubMed

    Woo, L N; Guo, W Y; Wang, X; Young, A; Salehi, S; Hin, A; Zhang, Y; Scott, J A; Chow, C W

    2018-05-02

    Animal models of allergic airways inflammation are useful tools in studying the pathogenesis of asthma and potential therapeutic interventions. The different allergic airways inflammation models available to date employ varying doses, frequency, duration and types of allergen, which lead to the development of different features of asthma; showing varying degrees of airways inflammation and hyper-responsiveness (AHR) and airways remodeling. Models that also exhibit airway remodeling, a key feature of asthma, in addition to AHR and airway inflammation typically require 5-12 weeks to develop. In this report, we describe a 4-week mouse model of house dust mite (HDM)-induced allergic airways inflammation, and compare the phenotypic features of two different doses of HDM exposures (10 µg and 25 µg) for 5 days/week with a well-characterized 8-week chronic HDM model. We found that 4 weeks of intranasal HDM (25 µg in 35 µl saline; 5 days/week) resulted in AHR, airway inflammation and airway remodeling that were comparable to the 8-week model. We conclude that this new 4-week HDM model is another useful tool in studies of human asthma that offers advantages of shorter duration for development and decreased costs when compared to other models that require longer durations of exposure (5-12 weeks) to develop.

  4. 21 CFR 870.1340 - Catheter introducer.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Catheter introducer. 870.1340 Section 870.1340 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1340 Catheter introducer...

  5. 21 CFR 870.1250 - Percutaneous catheter.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Percutaneous catheter. 870.1250 Section 870.1250 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1250 Percutaneous catheter...

  6. 21 CFR 870.1250 - Percutaneous catheter.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Percutaneous catheter. 870.1250 Section 870.1250 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1250 Percutaneous catheter...

  7. 21 CFR 870.1340 - Catheter introducer.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Catheter introducer. 870.1340 Section 870.1340 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1340 Catheter introducer...

  8. Spontaneous rotation of the monorail-type guide extension support catheter during advancement of a curved guiding catheter: the potential hazard of twisting with the coronary guidewire.

    PubMed

    Hashimoto, Sho; Takahashi, Akihiko; Yamada, Takeshi; Mizuguchi, Yukio; Taniguchi, Norimasa; Hata, Tetsuya; Nakajima, Shunsuke

    2017-11-20

    The extension support guiding catheter has been used to perform complex percutaneous coronary intervention to increase back-up support for the guiding catheter or to ensure deep intubation for device delivery. However, because of its monorail design, advancement of the stent into the distal extension tubing segment is sometimes problematic. Although this problem is considered due to simple collision of the stent, operators have observed tangling between a monorail extension catheter and coronary guidewire in some patients. To examine movement of the collar of the extension guide catheter during advancement of the guiding catheter, we set up an in vitro model in which the guiding catheter had two curves. Rotation of the extension guide catheter was examined by both fluoroscopic imaging and movement of the hub of the proximal end of the catheter. During advancement in the first curve, the collar moved toward the outer side of the curve of the guiding catheter as the operator pushed the shaft of the extension guiding catheter, which overrode the guidewire. After crossing the first curve, the collar moved again to the outer side of the second curve (the inner side of the first curve) of the mother catheter, and then, another clockwise rotation was observed in the proximal hub. Consequently, the collar and tubing portion of the extension guide catheter rotated 360° around the coronary guidewire, and the monorail extension catheter and guidewire became tangled. There is a potential risk of unintentional twisting with the guidewire during advancement into the curved guiding catheter because of its monorail design.

  9. Multifunctional Catheters Combining Intracardiac Ultrasound Imaging and Electrophysiology Sensing

    PubMed Central

    Stephens, Douglas N.; Cannata, Jonathan; Liu, Ruibin; Zhao, Jian Zhong; Shung, K. Kirk; Nguyen, Hien; Chia, Raymond; Dentinger, Aaron; Wildes, Douglas; Thomenius, Kai E.; Mahajan, Aman; Shivkumar, Kalyanam; Kim, Kang; O’Donnell, Matthew; Nikoozadeh, Amin; Oralkan, Omer; Khuri-Yakub, Pierre T.; Sahn, David J.

    2015-01-01

    A family of 3 multifunctional intracardiac imaging and electrophysiology (EP) mapping catheters has been in development to help guide diagnostic and therapeutic intracardiac EP procedures. The catheter tip on the first device includes a 7.5 MHz, 64-element, side-looking phased array for high resolution sector scanning. The second device is a forward-looking catheter with a 24-element 14 MHz phased array. Both of these catheters operate on a commercial imaging system with standard software. Multiple EP mapping sensors were mounted as ring electrodes near the arrays for electrocardiographic synchronization of ultrasound images and used for unique integration with EP mapping technologies. To help establish the catheters’ ability for integration with EP interventional procedures, tests were performed in vivo in a porcine animal model to demonstrate both useful intracardiac echocardiographic (ICE) visualization and simultaneous 3-D positional information using integrated electroanatomical mapping techniques. The catheters also performed well in high frame rate imaging, color flow imaging, and strain rate imaging of atrial and ventricular structures. The companion paper of this work discusses the catheter design of the side-looking catheter with special attention to acoustic lens design. The third device in development is a 10 MHz forward-looking ring array that is to be mounted at the distal tip of a 9F catheter to permit use of the available catheter lumen for adjunctive therapy tools. PMID:18986948

  10. Operative endoscopy of the airway

    PubMed Central

    Walters, Dustin M.

    2016-01-01

    Airway endoscopy has long been an important and useful tool in the management of thoracic diseases. As thoracic specialists have gained experience with both flexible and rigid bronchoscopic techniques, the technology has continued to evolve so that bronchoscopy is currently the foundation for diagnosis and treatment of many thoracic ailments. Airway endoscopy plays a significant role in the biopsy of tumors within the airways, mediastinum, and lung parenchyma. Endoscopic methods have been developed to treat benign and malignant airway stenoses and tracheomalacia. And more recently, techniques have been conceived to treat end-stage emphysema and prolonged air leaks in select patients. This review describes the abundant uses of airway endoscopy, as well as technical considerations and limitations of the current technologies. PMID:26981263

  11. Humidification on Ventilated Patients: Heated Humidifications or Heat and Moisture Exchangers?

    PubMed

    Cerpa, F; Cáceres, D; Romero-Dapueto, C; Giugliano-Jaramillo, C; Pérez, R; Budini, H; Hidalgo, V; Gutiérrez, T; Molina, J; Keymer, J

    2015-01-01

    The normal physiology of conditioning of inspired gases is altered when the patient requires an artificial airway access and an invasive mechanical ventilation (IMV). The endotracheal tube (ETT) removes the natural mechanisms of filtration, humidification and warming of inspired air. Despite the noninvasive ventilation (NIMV) in the upper airways, humidification of inspired gas may not be optimal mainly due to the high flow that is being created by the leakage compensation, among other aspects. Any moisture and heating deficit is compensated by the large airways of the tracheobronchial tree, these are poorly suited for this task, which alters mucociliary function, quality of secretions, and homeostasis gas exchange system. To avoid the occurrence of these events, external devices that provide humidification, heating and filtration have been developed, with different degrees of evidence that support their use.

  12. Fibrinogen release and deposition on urinary catheters placed during urologic procedures

    PubMed Central

    Potretzke, Aaron M.; Schreiber, Henry L.; Park, Alyssa M.; Pinkner, Jerome S.; Caparon, Michael G.; Hultgren, Scott J.; Desai, Alana

    2016-01-01

    Purpose Catheter-associated urinary tract infections (CAUTI) account for ~40% of all hospital-acquired infections worldwide, with more than one million cases diagnosed annually. Recent data from a CAUTI animal model has shown that inflammation induced by catheterization releases host fibrinogen that accumulates on the catheter. Further, Enterococcus faecalis catheter colonization was found to be dependent on EbpA, a fibrinogen binding adhesin. We sought to evaluate this mechanism in a human model. Materials and methods Urinary catheters were collected from human subjects hospitalized for surgical or non-surgical urologic procedures. Catheters were subjected to immunofluorescence analyses by incubating them with anti-fibrinogen antibody and then stained for fluorescence. The fluorescence intensity was compared to standard catheters. Catheters were incubated with strains of Enterococcus faecalis, Staphylococcus aureus, or Candida to assess their binding to fibrinogen-laden catheters. Results Fifty catheters were collected after various surgical and urological procedures. In vivo dwell time ranged from 1 hour to 59 days. All catheters had fibrinogen deposition and its accumulation was dependent on dwell time but not on surgical procedure or catheter material. Catheters were probed ex vivo with E. faecalis, S. aureus, and Candida albicans, which bound to catheters only in those regions where fibrinogen was deposited. Conclusions Taken together, these data show that urinary catheters act as a binding surface for accumulation of fibrinogen, which is released due to inflammation resulting from a urological procedure or from catheter placement, creating a niche that can be exploited by uropathogens to cause CAUTI. PMID:26827873

  13. Dosimetric equivalence of nonstandard HDR brachytherapy catheter patterns

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cunha, J. A. M.; Hsu, I-C.; Pouliot, J.

    2009-01-15

    Purpose: To determine whether alternative high dose rate prostate brachytherapy catheter patterns can result in similar or improved dose distributions while providing better access and reducing trauma. Materials and Methods: Standard prostate cancer high dose rate brachytherapy uses a regular grid of parallel needle positions to guide the catheter insertion. This geometry does not easily allow the physician to avoid piercing the critical structures near the penile bulb nor does it provide position flexibility in the case of pubic arch interference. This study used CT datasets with 3 mm slice spacing from ten previously treated patients and digitized new cathetersmore » following three hypothetical catheter patterns: conical, bi-conical, and fireworks. The conical patterns were used to accommodate a robotic delivery using a single entry point. The bi-conical and fireworks patterns were specifically designed to avoid the critical structures near the penile bulb. For each catheter distribution, a plan was optimized with the inverse planning algorithm, IPSA, and compared with the plan used for treatment. Irrelevant of catheter geometry, a plan must fulfill the RTOG-0321 dose criteria for target dose coverage (V{sub 100}{sup Prostate}>90%) and organ-at-risk dose sparing (V{sub 75}{sup Bladder}<1 cc, V{sub 75}{sup Rectum}<1 cc, V{sub 125}{sup Urethra}<<1 cc). Results: The three nonstandard catheter patterns used 16 nonparallel, straight divergent catheters, with entry points in the perineum. Thirty plans from ten patients with prostate sizes ranging from 26 to 89 cc were optimized. All nonstandard patterns fulfilled the RTOG criteria when the clinical plan did. In some cases, the dose distribution was improved by better sparing the organs-at-risk. Conclusion: Alternative catheter patterns can provide the physician with additional ways to treat patients previously considered unsuited for brachytherapy treatment (pubic arch interference) and facilitate robotic guidance

  14. Catheter placement for lysis of spontaneous intracerebral hematomas: does a catheter position in the core of the hematoma allow more effective and faster hematoma lysis?

    PubMed

    Malinova, Vesna; Schlegel, Anna; Rohde, Veit; Mielke, Dorothee

    2017-07-01

    For the fibrinolytic therapy of intracerebral hematomas (ICH) using recombinant tissue plasminogen activator (rtPA), a catheter position in the core of the hematoma along the largest clot diameter was assumed to be optimal for an effective clot lysis. However, it never had been proven that core position indeed enhances clot lysis if compared with less optimal catheter positions. In this study, the impact of the catheter position on the effectiveness and on the time course of clot lysis was evaluated. We analyzed the catheter position using a relative error calculating the distance perpendicular to the catheter's center in relation to hematoma's diameter and evaluated the relative hematoma volume reduction (RVR). The correlation of the RVR with the catheter position was evaluated. Additionally, we tried to identify patterns of clot lysis with different catheter positions. The patient's outcome at discharge was evaluated using the Glasgow outcome score. A total of 105 patients were included in the study. The mean hematoma volume was 56 ml. The overall RVR was 62.7 %. In 69 patients, a catheter position in the core of the clot was achieved. We found no significant correlation between catheter position and hematoma RVR (linear regression, p = 0.14). Core catheter position leads to more symmetrical hematoma RVR. Faster clot lysis happens in the vicinity of the catheter openings. We found no significant difference in the patient's outcome dependent on the catheter position (linear regression, p = 0.90). The catheter position in the core of the hematoma along its largest diameter does not significantly influence the effectiveness of clot lysis after rtPA application.

  15. Endogenous gamma-aminobutyric acid modulates tonic guinea pig airway tone and propofol-induced airway smooth muscle relaxation.

    PubMed

    Gallos, George; Gleason, Neil R; Virag, Laszlo; Zhang, Yi; Mizuta, Kentaro; Whittington, Robert A; Emala, Charles W

    2009-04-01

    Emerging evidence indicates that an endogenous autocrine/paracrine system involving gamma-aminobutyric acid (GABA) is present in airways. GABAA channels, GABAB receptors, and the enzyme that synthesizes GABA have been identified in airway epithelium and smooth muscle. However, the endogenous ligand itself, GABA, has not been measured in airway tissues. The authors sought to demonstrate that GABA is released in response to contractile agonists and tonically contributes a prorelaxant component to contracted airway smooth muscle. The amount and cellular localization of GABA in upper guinea pig airways under resting and contracted tone was determined by high pressure liquid chromatography and immunohistochemistry, respectively. The contribution that endogenous GABA imparts on the maintenance of airway smooth muscle acetylcholine-induced contraction was assessed in intact guinea pig airway tracheal rings using selective GABAA antagonism (gabazine) under resting or acetylcholine-contracted conditions. The ability of an allosteric agent (propofol) to relax a substance P-induced relaxation in an endogenous GABA-dependent manner was assessed. GABA levels increased and localized to airway smooth muscle after contractile stimuli in guinea pig upper airways. Acetylcholine-contracted guinea pig tracheal rings exhibited an increase in contracted force upon addition of the GABAA antagonist gabazine that was subsequently reversed by the addition of the GABAA agonist muscimol. Propofol dose-dependently relaxed a substance P contraction that was blocked by gabazine. These studies demonstrate that GABA is endogenously present and increases after contractile stimuli in guinea pig upper airways and that endogenous GABA contributes a tonic prorelaxant component in the maintenance of airway smooth muscle tone.

  16. Endogenous γ-aminobutyric Acid Modulates Tonic Guinea Pig Airway Tone and Propofol-induced Airway Smooth Muscle Relaxation

    PubMed Central

    Gallos, George; Gleason, Neil R.; Virag, Laszlo; Zhang, Yi; Mizuta, Kentauro; Whittington, Robert A.; Emala, Charles W.

    2009-01-01

    Background Emerging evidence indicates that an endogenous autocrine/paracrine system involving γ-aminobutyric acid (GABA) is present in airways. GABAA channels, GABAB receptors and the enzyme that synthesizes GABA have been identified in airway epithelium and smooth muscle. However, the endogenous ligand itself, GABA, has not been measured in airway tissues. We sought to demonstrate that GABA is released in response to contractile agonists and tonically contributes a pro-relaxant component to contracted airway smooth muscle. Methods The amount and cellular localization of GABA in upper guinea pig airways under resting and contracted tone was determined by high pressure liquid chromatography and immunohistochemistry, respectively. The contribution that endogenous GABA imparts on the maintenance of airway smooth muscle acetylcholine-induced contraction was assessed in intact guinea pig airway tracheal rings using selective GABAA antagonism (gabazine) under resting or acetylcholine-contracted conditions. The ability of an allosteric agent (propofol) to relax a substance P-induced relaxation in an endogenous GABA-dependent manner was assessed. Results GABA levels increased and localized to airway smooth muscle following contractile stimuli in guinea pig upper airways. Acetylcholine-contracted guinea pig tracheal rings exhibited an increase in contracted force upon addition of the GABAA antagonist gabazine which was subsequently reversed by the addition of the GABAA agonist muscimol. Propofol dose-dependently relaxed a substance P contraction that was blocked by gabazine. Conclusion These studies demonstrate that GABA is endogenously present and increases following contractile stimuli in guinea pig upper airways and that endogenous GABA contributes a tonic pro-relaxant component in the maintenance of airway smooth muscle tone. PMID:19322939

  17. 21 CFR 870.1380 - Catheter stylet.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Catheter stylet. 870.1380 Section 870.1380 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1380 Catheter stylet. (a...

  18. 21 CFR 870.1280 - Steerable catheter.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Steerable catheter. 870.1280 Section 870.1280 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1280 Steerable catheter. (a...

  19. 21 CFR 870.1300 - Catheter cannula.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Catheter cannula. 870.1300 Section 870.1300 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1300 Catheter cannula. (a...

  20. 21 CFR 870.1380 - Catheter stylet.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Catheter stylet. 870.1380 Section 870.1380 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1380 Catheter stylet. (a...

  1. 21 CFR 870.1300 - Catheter cannula.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Catheter cannula. 870.1300 Section 870.1300 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1300 Catheter cannula. (a...

  2. 21 CFR 870.1280 - Steerable catheter.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Steerable catheter. 870.1280 Section 870.1280 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1280 Steerable catheter. (a...

  3. Neurokinin-1 receptor mediates stress-exacerbated allergic airway inflammation and airway hyperresponsiveness in mice.

    PubMed

    Joachim, Ricarda A; Sagach, Viktoriya; Quarcoo, David; Dinh, Q Thai; Arck, Petra C; Klapp, Burghard F

    2004-01-01

    A wealth of clinical observation has suggested that stress and asthma morbidity are associated. We have previously established a mouse model of stress-exacerbated allergic airway inflammation, which reflects major clinical findings. The aim of the current study was to investigate the role of the neurokinin- (NK-)1 receptor in the mediation of stress effects in allergic airway inflammation. BALB/c mice were systemically sensitized with ovalbumin (OVA) on assay days 1, 14, and 21 and repeatedly challenged with OVA aerosol on days 26 and 27. Sound stress was applied to the animals for 24 hours, starting with the first airway challenge. Additionally, one group of stressed and one group of nonstressed mice received the highly specific NK-1 receptor antagonist RP 67580. Bronchoalveolar lavage fluid was obtained, and cell numbers and differentiation were determined. Airway hyperreactivity was measured in vitro by electrical field stimulation of tracheal smooth-muscle elements. Application of stress in sensitized and challenged animals resulted in a significant increase in leukocyte number in the bronchoalveolar lavage fluid. Furthermore, stressed animals showed enhanced airway reactivity. The increase of inflammatory cells and airway reactivity was blocked by treatment of animals with the NK-1 receptor antagonist. These data indicate that the NK-1 receptor plays an important role in mediating stress effects in allergen-induced airway inflammation.

  4. The Human Airway Epithelial Basal Cell Transcriptome

    PubMed Central

    Wang, Rui; Zwick, Rachel K.; Ferris, Barbara; Witover, Bradley; Salit, Jacqueline; Crystal, Ronald G.

    2011-01-01

    Background The human airway epithelium consists of 4 major cell types: ciliated, secretory, columnar and basal cells. During natural turnover and in response to injury, the airway basal cells function as stem/progenitor cells for the other airway cell types. The objective of this study is to better understand human airway epithelial basal cell biology by defining the gene expression signature of this cell population. Methodology/Principal Findings Bronchial brushing was used to obtain airway epithelium from healthy nonsmokers. Microarrays were used to assess the transcriptome of basal cells purified from the airway epithelium in comparison to the transcriptome of the differentiated airway epithelium. This analysis identified the “human airway basal cell signature” as 1,161 unique genes with >5-fold higher expression level in basal cells compared to differentiated epithelium. The basal cell signature was suppressed when the basal cells differentiated into a ciliated airway epithelium in vitro. The basal cell signature displayed overlap with genes expressed in basal-like cells from other human tissues and with that of murine airway basal cells. Consistent with self-modulation as well as signaling to other airway cell types, the human airway basal cell signature was characterized by genes encoding extracellular matrix components, growth factors and growth factor receptors, including genes related to the EGF and VEGF pathways. Interestingly, while the basal cell signature overlaps that of basal-like cells of other organs, the human airway basal cell signature has features not previously associated with this cell type, including a unique pattern of genes encoding extracellular matrix components, G protein-coupled receptors, neuroactive ligands and receptors, and ion channels. Conclusion/Significance The human airway epithelial basal cell signature identified in the present study provides novel insights into the molecular phenotype and biology of the stem

  5. 21 CFR 870.1350 - Catheter balloon repair kit.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Catheter balloon repair kit. 870.1350 Section 870... repair kit. (a) Identification. A catheter balloon repair kit is a device used to repair or replace the balloon of a balloon catheter. The kit contains the materials, such as glue and balloons, necessary to...

  6. 21 CFR 870.1350 - Catheter balloon repair kit.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Catheter balloon repair kit. 870.1350 Section 870... repair kit. (a) Identification. A catheter balloon repair kit is a device used to repair or replace the balloon of a balloon catheter. The kit contains the materials, such as glue and balloons, necessary to...

  7. 21 CFR 870.1350 - Catheter balloon repair kit.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Catheter balloon repair kit. 870.1350 Section 870... repair kit. (a) Identification. A catheter balloon repair kit is a device used to repair or replace the balloon of a balloon catheter. The kit contains the materials, such as glue and balloons, necessary to...

  8. Effects of lung disease on the three-dimensional structure and air flow pattern in the human airway tree

    NASA Astrophysics Data System (ADS)

    van de Moortele, Tristan; Nemes, Andras; Wendt, Christine; Coletti, Filippo

    2016-11-01

    The morphological features of the airway tree directly affect the air flow features during breathing, which determines the gas exchange and inhaled particle transport. Lung disease, Chronic Obstructive Pulmonary Disease (COPD) in this study, affects the structural features of the lungs, which in turn negatively affects the air flow through the airways. Here bronchial tree air volume geometries are segmented from Computed Tomography (CT) scans of healthy and diseased subjects. Geometrical analysis of the airway centerlines and corresponding cross-sectional areas provide insight into the specific effects of COPD on the airway structure. These geometries are also used to 3D print anatomically accurate, patient specific flow models. Three-component, three-dimensional velocity fields within these models are acquired using Magnetic Resonance Imaging (MRI). The three-dimensional flow fields provide insight into the change in flow patterns and features. Additionally, particle trajectories are determined using the velocity fields, to identify the fate of therapeutic and harmful inhaled aerosols. Correlation between disease-specific and patient-specific anatomical features with dysfunctional airflow patterns can be achieved by combining geometrical and flow analysis.

  9. 21 CFR 880.5200 - Intravascular catheter.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... Devices § 880.5200 Intravascular catheter. (a) Identification. An intravascular catheter is a device that consists of a slender tube and any necessary connecting fittings and that is inserted into the patient's vascular system for short term use (less than 30 days) to sample blood, monitor blood pressure, or...

  10. Physical principle of airway design in human lungs

    NASA Astrophysics Data System (ADS)

    Park, Keunhwan; Son, Taeho; Kim, Wonjung; Kim, Ho-Young

    2014-11-01

    From an engineering perspective, lungs are natural microfluidic devices that extract oxygen from air. In the bronchial tree, airways branch by dichotomy with a systematic reduction of their diameters. It is generally accepted that in conducting airways, which air passes on the way to the acinar airways from the atmosphere, the reduction ratio of diameter is closely related to the minimization of viscous dissipation. Such a principle is formulated as the Hess-Murray law. However, in acinar airways, where oxygen transfer to alveolae occurs, the diameter reduction with progressive generations is more moderate than in conducting airways. Noting that the dominant transfer mechanism in acinar airways is diffusion rather than advection, unlike conducting airways, we construct a mathematical model for oxygen transfer through a series of acinar airways. Our model allows us to predict the optimal airway reduction ratio that maximizes the oxygen transfer in a finite airway volume, thereby rationalizing the observed airway reduction ratio in acinar airways.

  11. Airway management in cervical spine injury

    PubMed Central

    Austin, Naola; Krishnamoorthy, Vijay; Dagal, Arman

    2014-01-01

    To minimize risk of spinal cord injury, airway management providers must understand the anatomic and functional relationship between the airway, cervical column, and spinal cord. Patients with known or suspected cervical spine injury may require emergent intubation for airway protection and ventilatory support or elective intubation for surgery with or without rigid neck stabilization (i.e., halo). To provide safe and efficient care in these patients, practitioners must identify high-risk patients, be comfortable with available methods of airway adjuncts, and know how airway maneuvers, neck stabilization, and positioning affect the cervical spine. This review discusses the risks and benefits of various airway management strategies as well as specific concerns that affect patients with known or suspected cervical spine injury. PMID:24741498

  12. Percutaneous intrapericardial echocardiography during catheter ablation: a feasibility study.

    PubMed

    Horowitz, Barbara Natterson; Vaseghi, Marmar; Mahajan, Aman; Cesario, David A; Buch, Eric; Valderrábano, Miguel; Boyle, Noel G; Ellenbogen, Kenneth A; Shivkumar, Kalyanam

    2006-11-01

    Percutaneous pericardial access, epicardial mapping, and ablation have been used successfully for catheter ablation procedures. The purpose of this study was to evaluate the safety and feasibility of closed-chest direct epicardial ultrasound imaging for aiding cardiac catheter ablation procedures. An intracardiac ultrasound catheter was used for closed-chest epicardial imaging of the heart in 10 patients undergoing percutaneous epicardial access for catheter ablation. All patients underwent concomitant intracardiac echocardiography and preprocedural transesophageal echocardiography. Using a double-wire technique, two sheaths were placed in the pericardium, and a phased-array ultrasound catheter was manipulated within the pericardial sinuses for imaging. Multiple images from varying angles were obtained for catheter navigation. Notably, image stability was excellent, and structures such as the left atrial appendage were seen in great detail. No complications resulting from use of the ultrasound catheter in the pericardium occurred, and no restriction of movement due to the presence of the additional catheter in the pericardial space was observed. Wall motion was correlated to voltage maps in five patients and showed that areas of scars correlated with wall-motion abnormalities. Normal wall-motion score correlated to sensed signals of 4.2 +/- 0.3 mV (normal myocardium >1.5 mV), and scores >1 correlated to areas with signals <0.5 mV in that territory). Intrapericardial imaging using an ultrasound catheter is feasible and safe and has the potential to provide additional valuable information for complex ablation procedures.

  13. Relationships between equine airway reactivity measured by flowmetric plethysmography and specific indicators of airway inflammation in horses with suspected inflammatory airway disease.

    PubMed

    Wichtel, M; Gomez, D; Burton, S; Wichtel, J; Hoffman, A

    2016-07-01

    Agreement between airway reactivity measured by flowmetric plethysmography and histamine bronchoprovocation, and lower airway inflammation measured by bronchoalveolar lavage (BAL) cytology, has not been studied in horses with suspected inflammatory airway disease (IAD). We tested the hypothesis that airway reactivity is associated with BAL cytology in horses presenting for unexplained poor performance and/or chronic cough. Prospective clinical study. Forty-five horses, predominantly young Standardbred racehorses, presenting for unexplained poor performance or chronic cough, underwent endoscopic evaluation, tracheal wash, flowmetric plethysmography with histamine bronchoprovocation and BAL. Histamine response was measured by calculating PC35, the concentration of nebulised histamine eliciting an increase in Δflow of 35%. In this population, there was no significant correlation between histamine response and cell populations in BAL cytology. When airway hyperreactivity (AHR) was defined as ≥35% increase in Δflow at a histamine concentration of <6 mg/ml, 24 of the 45 horses (53%) were determined to have AHR. Thirty-three (73%) had either abnormal BAL cytology or AHR, and were diagnosed with IAD on this basis. Of horses diagnosed with IAD, 9 (27%) had an abnormal BAL, 11 (33%) had AHR and 13 (39%) had both. Airway reactivity and BAL cytology did not show concordance in this population of horses presenting for unexplained poor performance and/or chronic cough. Failure to include tests of airway reactivity may lead to underdiagnosis of IAD in young Standardbred racehorses that present with clinical signs suggestive of IAD. © 2015 EVJ Ltd.

  14. Anatomic Optical Coherence Tomography of Upper Airways

    NASA Astrophysics Data System (ADS)

    Chin Loy, Anthony; Jing, Joseph; Zhang, Jun; Wang, Yong; Elghobashi, Said; Chen, Zhongping; Wong, Brian J. F.

    The upper airway is a complex and intricate system responsible for respiration, phonation, and deglutition. Obstruction of the upper airways afflicts an estimated 12-18 million Americans. Pharyngeal size and shape are important factors in the pathogenesis of airway obstructions. In addition, nocturnal loss in pharyngeal muscular tone combined with high pharyngeal resistance can lead to collapse of the airway and periodic partial or complete upper airway obstruction. Anatomical optical coherence tomography (OCT) has the potential to provide high-speed three-dimensional tomographic images of the airway lumen without the use of ionizing radiation. In this chapter we describe the methods behind endoscopic OCT imaging and processing to generate full three dimensional anatomical models of the human airway which can be used in conjunction with numerical simulation methods to assess areas of airway obstruction. Combining this structural information with flow dynamic simulations, we can better estimate the site and causes of airway obstruction and better select and design surgery for patients with obstructive sleep apnea.

  15. A magnetic-resonance-imaging-compatible remote catheter navigation system.

    PubMed

    Tavallaei, Mohammad Ali; Thakur, Yogesh; Haider, Syed; Drangova, Maria

    2013-04-01

    A remote catheter navigation system compatible with magnetic resonance imaging (MRI) has been developed to facilitate MRI-guided catheterization procedures. The interventionalist's conventional motions (axial motion and rotation) on an input catheter - acting as the master - are measured by a pair of optical encoders, and a custom embedded system relays the motions to a pair of ultrasonic motors. The ultrasonic motors drive the patient catheter (slave) within the MRI scanner, replicating the motion of the input catheter. The performance of the remote catheter navigation system was evaluated in terms of accuracy and delay of motion replication outside and within the bore of the magnet. While inside the scanner bore, motion accuracy was characterized during the acquisition of frequently used imaging sequences, including real-time gradient echo. The effect of the catheter navigation system on image signal-to-noise ratio (SNR) was also evaluated. The results show that the master-slave system has a maximum time delay of 41 ± 21 ms in replicating motion; an absolute value error of 2 ± 2° was measured for radial catheter motion replication over 360° and 1.0 ± 0.8 mm in axial catheter motion replication over 100 mm of travel. The worst-case SNR drop was observed to be 2.5%.

  16. Factors associated with peritoneal dialysis catheter complications in children.

    PubMed

    Stewart, Camille L; Acker, Shannon N; Pyle, Laura L; Kulungowski, Ann; Cadnapaphornchai, Melissa; Bruny, Jennifer L; Karrer, Frederick

    2016-01-01

    Peritoneal dialysis (PD) is a common method of renal replacement therapy for children. However, placement of PD catheters has risk, and some are never used. We conducted a retrospective chart review of children with a PD catheter placed between 2000 and 2014. Logistic regression analyses were used to identify covariates associated with complications. We identified 175 children with PD catheters. 110 complications developed in 80 children (45.7%). Complications including unexpected return to the operating room and peritonitis increased as the length of time a catheter was in place increased. Children who weighed <12.4 kg had 3.2 times greater odds of developing a leak (95% CI 1.21-8.63, p=0.02). Twelve children never used their PD catheters, 9 with acute kidney injury (AKI) who recovered from their disease more quickly than expected. No covariate was associated with nonuse. Complications with PD catheters are common and increase the longer catheters are in place. Lower weight children are at greater risk of PD catheter leak. Decreased initial volumes of dialysate in smaller children may mitigate this risk. Nonuse may be reduced if dialysis is permitted the day of placement for children with AKI. Copyright © 2016 Elsevier Inc. All rights reserved.

  17. Indwelling catheters and medical implants with FXIIIa inhibitors: a novel approach to the treatment of catheter and medical device-related infections

    PubMed Central

    Daneshpour, Nooshin; Collighan, Russell; Perrie, Yvonne; Lambert, Peter; Rathbone, Dan; Lowry, Deborah; Griffin, Martin

    2013-01-01

    Central venous catheters (CVCs) are being utilized with increasing frequency in intensive care and general medical wards. In spite of the extensive experience gained in their application, CVCs are related to the long-term risks of catheter sheath formation, infection and thrombosis (of the catheter or vessel itself) during catheterisation. Such CVC-related-complications are associated with increased morbidity, mortality, duration of hospitalisation and medical care cost [1]. The present study incorporates a novel group of Factor XIIIa (FXIIIa, plasma transglutaminase) inhibitors into a lubricious silicone elastomer in order to generate an optimized drug delivery system whereby a secondary sustained drug release profile occurs following an initial burst release for catheters and other medical devices. We propose that the incorporation of FXIIIa inhibitors into catheters, stents and other medical implant devices would reduce the incidence of catheter sheath formation, thrombotic occlusion and associated staphylococcal infection. This technique could be used as a local delivery system for extended release with an immediate onset of action for other poorly aqueous soluble compounds. PMID:23022540

  18. Radiology-guided forceps biopsy and airway stenting in severe airway stenosis.

    PubMed

    Li, Zong Ming; Wu, Gang; Han, Xin Wei; Ren, Ke Wei; Zhu, Ming

    2014-01-01

    We aimed to determine the feasibility, safety, and effectiveness of radiology-guided forceps biopsy and airway stenting in patients with severe airway stenosis. This study involved 28 patients with severe airway stenosis who underwent forceps biopsy between October 2006 and September 2011. Chest multislice computed tomography was used to determine the location and extent of stenosis. Sixteen patients had tracheal stenosis, two patients had stenosis of the tracheal carina, six patients had stenosis of the left main bronchus, and four patients had stenosis of the right main bronchus. Forceps biopsy and stenting of the stenosed area were performed under fluoroscopic guidance in digital subtraction angiography and the biopsy specimens were analyzed histopathologically. We contacted the patients via phone call and utilized a standardized questionnaire to determine their medical condition during a postoperative three-month follow-up. The technical success rate of radiology-guided forceps biopsy was 100%. Biopsy specimens were obtained in all patients. Dyspnea was relieved immediately after stent placement. No serious complications, such as tracheal hemorrhage or perforation, mediastinal emphysema, or asphyxia, occurred. Radiology-guided forceps biopsy and airway stenting can be used for the emergency treatment of severe airway stenosis. This method appears to be safe and effective, and it may be an alternative therapeutic option in patients who cannot tolerate fiberoptic bronchoscopy.

  19. Radiology-guided forceps biopsy and airway stenting in severe airway stenosis

    PubMed Central

    Li, Zong-Ming; Wu, Gang; Han, Xin-Wei; Ren, Ke-Wei; Zhu, Ming

    2014-01-01

    PURPOSE We aimed to determine the feasibility, safety, and effectiveness of radiology-guided forceps biopsy and airway stenting in patients with severe airway stenosis. MATERIALS AND METHODS This study involved 28 patients with severe airway stenosis who underwent forceps biopsy between October 2006 and September 2011. Chest multislice computed tomography was used to determine the location and extent of stenosis. Sixteen patients had tracheal stenosis, two patients had stenosis of the tracheal carina, six patients had stenosis of the left main bronchus, and four patients had stenosis of the right main bronchus. Forceps biopsy and stenting of the stenosed area were performed under fluoroscopic guidance in digital subtraction angiography and the biopsy specimens were analyzed histopathologically. We contacted the patients via phone call and utilized a standardized questionnaire to determine their medical condition during a postoperative three-month follow-up. RESULTS The technical success rate of radiology-guided forceps biopsy was 100%. Biopsy specimens were obtained in all patients. Dyspnea was relieved immediately after stent placement. No serious complications, such as tracheal hemorrhage or perforation, mediastinal emphysema, or asphyxia, occurred. CONCLUSION Radiology-guided forceps biopsy and airway stenting can be used for the emergency treatment of severe airway stenosis. This method appears to be safe and effective, and it may be an alternative therapeutic option in patients who cannot tolerate fiberoptic bronchoscopy. PMID:24808434

  20. High-speed upper-airway imaging using full-range optical coherence tomography

    NASA Astrophysics Data System (ADS)

    Jing, Joseph; Zhang, Jun; Loy, Anthony Chin; Wong, Brian J. F.; Chen, Zhongping

    2012-11-01

    Obstruction in the upper airway can often cause reductions in breathing or gas exchange efficiency and lead to rest disorders such as sleep apnea. Imaging diagnosis of the obstruction region has been accomplished using computed tomography (CT) and magnetic resonance imaging (MRI). However CT requires the use of ionizing radiation, and MRI typically requires sedation of the patient to prevent motion artifacts. Long-range optical coherence tomography (OCT) has the potential to provide high-speed three-dimensional tomographic images with high resolution and without the use of ionizing radiation. In this paper, we present work on the development of a long-range OCT endoscopic probe with 1.2 mm OD and 20 mm working distance used in conjunction with a modified Fourier domain swept source OCT system to acquire structural and anatomical datasets of the human airway. Imaging from the bottom of the larynx to the end of the nasal cavity is completed within 40 s.

  1. 21 CFR 870.5150 - Embolectomy catheter.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... thromboemboli, i.e., blood clots which have migrated in blood vessels from one site in the vascular tree to... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Embolectomy catheter. 870.5150 Section 870.5150...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Therapeutic Devices § 870.5150 Embolectomy catheter...

  2. 21 CFR 870.5150 - Embolectomy catheter.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... thromboemboli, i.e., blood clots which have migrated in blood vessels from one site in the vascular tree to... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Embolectomy catheter. 870.5150 Section 870.5150...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Therapeutic Devices § 870.5150 Embolectomy catheter...

  3. 21 CFR 870.5150 - Embolectomy catheter.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... thromboemboli, i.e., blood clots which have migrated in blood vessels from one site in the vascular tree to... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Embolectomy catheter. 870.5150 Section 870.5150...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Therapeutic Devices § 870.5150 Embolectomy catheter...

  4. 21 CFR 870.5150 - Embolectomy catheter.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... thromboemboli, i.e., blood clots which have migrated in blood vessels from one site in the vascular tree to... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Embolectomy catheter. 870.5150 Section 870.5150...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Therapeutic Devices § 870.5150 Embolectomy catheter...

  5. Inflammatory bowel disease and airway diseases.

    PubMed

    Vutcovici, Maria; Brassard, Paul; Bitton, Alain

    2016-09-14

    Airway diseases are the most commonly described lung manifestations of inflammatory bowel disease (IBD). However, the similarities in disease pathogenesis and the sharing of important environmental risk factors and genetic susceptibility suggest that there is a complex interplay between IBD and airway diseases. Recent evidence of IBD occurrence among patients with airway diseases and the higher than estimated prevalence of subclinical airway injuries among IBD patients support the hypothesis of a two-way association. Future research efforts should be directed toward further exploration of this association, as airway diseases are highly prevalent conditions with a substantial public health impact.

  6. Use of monorail PTCA balloon catheter for local drug delivery.

    PubMed

    Trehan, Vijay; Nair, Girish M; Gupta, Mohit D

    2007-01-01

    We report the use of monorail coronary balloon as an infusion catheter to give bailout abciximab selectively into the site of stent thrombosis as an adjunct to plain old balloon angioplasty (POBA) in a patient of subacute stent thrombosis of the left anterior descending coronary artery. The balloon component (polyamide material) of the monorail balloon catheter was shaved off the catheter so that abciximab injected through the balloon port of the catheter exited out the shaft of the balloon catheter at the site from where the balloon material was shaved off. We believe that selective infusion with abciximab along with POBA established antegrade flow and relieved the patient's ischemia. In the absence of essential hardware to give intracoronary drugs in an emergency situation, one may employ our technique of infusion through a monorail balloon catheter after shaving the balloon component from the catheter.

  7. Administration of SIN-1 induces guinea pig airway hyperresponsiveness through inactivation of airway neutral endopeptidase.

    PubMed

    Kanazawa, H; Hirata, K; Yoshikawa, J

    1999-12-01

    Peroxynitrite plays an important role in the pathogenesis of airway inflammation. We have already found that peroxynitrite may contribute to decreased beta(2)-adrenoceptor responses in airway smooth muscle. However, it is not known whether peroxynitrite can alter neutral endopeptidase (EC 3.4.24.11; NEP) activity in the airways. This study was designed to determine whether peroxynitrite induces airway hyperresponsiveness to substance P (SP) and endothelin-1 (ET-1) through the inactivation of airway NEP. We examined whether the administration of S-morpholinosydnonimine (SIN-1), a compound that releases peroxynitrite, increased bronchoconstrictor responses to SP and ET-1 in anesthetized guinea pigs. In addition, we assayed NEP activity in the airways of SIN-1-exposed guinea pigs. Though SIN-1 (10(-7) M) alone had no effect on pulmonary resistance, pretreatment with SIN-1 significantly enhanced SP- and ET-1-induced bronchoconstriction. Pretreatment with phosphoramidon, an NEP inhibitor, also enhanced SP- and ET-1-induced bronchoconstriction. However, simultaneous administration of phosphoramidon and SIN-1 had no additive effect on SP- and ET-1-induced bronchoconstriction. Peroxynitrite formation by SIN-1 was completely inhibited by N-acetylcysteine (NAC) and glutathione (GSH) in vitro, and pretreatment with NAC and GSH significantly reversed the potentiation by SIN-1 of SP-induced bronchoconstriction. In addition, the NEP activity of the trachea after SIN-1 exposure was significantly reduced compared to the level in control guinea pigs (solvent for SIN-1: 30.0+/-4.2 fmol.min(-1).mg tissue(-1); 10(-7) M SIN-1; 15.5+/-4.5 fmol.min(-1).mg tissue(-1), p<0.05). These findings suggest that peroxynitrite induces airway hyperresponsiveness to SP and ET-1 through the inactivation of airway NEP, and that peroxynitrite is an important mediator of the alterations in airway functions.

  8. Intrapericardial echocardiography: a novel catheter-based approach to cardiac imaging.

    PubMed

    Rodrigues, Ana Clara Tude; d'Avila, Andre; Houghtaling, Christopher; Ruskin, Jeremy N; Picard, Michael; Reddy, Vivek Y

    2004-03-01

    Transvascular catheter-based intracardiac echocardiography has been successfully used to help guide catheter ablation and electrophysiologic procedures. It has recently been demonstrated that catheters can be safely placed into the pericardial space to allow for epicardial cardiac mapping and ablation. We evaluated the feasibility of catheter-based intrapericardial echocardiography (IPE) during such procedures to identify cardiac structures and visualize intracardiac catheters. IPE was performed in 7 goats by placing a phased-array ultrasound transducer contained within a 10F steerable catheter into the pericardial space using the same transthoracic subxyphoid approach as used to map and ablate epicardial ventricular tachycardia. Images were obtained of cardiac structures and of intracardiac ablation catheters. After the procedure, the hearts were harvested to assess for possible IPE-related lesions. The IPE catheter could be easily placed inside the pericardial space in all animals. In 7 of 7 cases, longitudinal and short-axis views of right- and left-sided chambers and valves were obtained, similar in orientation to transesophageal echocardiography. Visualization of atrial appendages (6/7), pulmonary veins (6/7), coronary arteries (6/7), and coronary sinus (3/6) was also feasible. Assessment of intracardiac transvalvar and venous blood flow was achieved by spectral and color Doppler. The ablation catheter could be clearly visualized inside cardiac chambers. No arrhythmias were induced with IPE catheter manipulation. After harvesting the hearts, no lesions resulting from the procedure were observed. In this experimental setting, IPE was able to provide detailed images of cardiac structures and establish the relative position of the ablation catheter.

  9. Management of obstructed balloon catheters.

    PubMed Central

    Browning, G G; Barr, L; Horsburgh, A G

    1984-01-01

    Failure of a balloon catheter to deflate is not uncommon and prevents its removal. Methods of overcoming the problem include traction, bursting the balloon by overinflation, dissolving it with solvents, puncturing it percutaneously with a needle, or puncturing it with a wire stylet passed through the catheter. All except the last technique have major disadvantages and are of questionable safety. Transcatheter puncture of the balloon was used in 16 patients to remove obstructed balloon catheters without any technical difficulty, distress to the patient, or complication. The procedure is safe, simple, and does not require an anaesthetic. If necessary it could be performed safely by nursing or paramedical staff without the patient having to be admitted to hospital. It is the method of choice for the management of this problem. Images FIG 1 FIG 2 FIG 3 FIG 4 PMID:6428691

  10. Airway extravasation induced by increasing airway temperature in ovalbumin-sensitized rats

    PubMed Central

    Hsu, Chun-Chun; Tapia, Reyno J.; Lee, Lu-Yuan

    2015-01-01

    This study was carried out to determine whether hyperventilation of humidified warm air (HWA) induced airway extravasation in ovalbumin (Ova)-sensitized rats. Our results showed: 1) After isocapnic hyperventilation with HWA for 2 min, tracheal temperature (Ttr) was increased to 40.3°C, and the Evans blue contents in major airways and lung tissue were elevated to 651% and 707%, respectively, of that after hyperventilation with humidified room air in Ova-sensitized rats; this striking effect of HWA was absent in control rats. 2) The HWA-induced increase in Evans blue content in sensitized rats was completely prevented by a pretreatment with either L-732138, a selective antagonist of neurokinin type 1 (NK-1) receptor, or formoterol, a selective agonist of β2 adrenoceptor. This study demonstrated that an increase in airway temperature induced protein extravasation in the major airways and lung tissue of sensitized rats, and an activation of the NK-1 receptor by tachykinins released from bronchopulmonary C-fiber nerve endings was primarily responsible. PMID:25864799

  11. Hemodialysis tunneled central venous catheters: five-year outcome analysis.

    PubMed

    Mandolfo, Salvatore; Acconcia, Pasqualina; Bucci, Raffaella; Corradi, Bruno; Farina, Marco; Rizzo, Maria Antonietta; Stucchi, Andrea

    2014-01-01

    Tunneled central venous catheters (tCVCs) are considered inferior to arteriovenous fistulas (AVFs) and grafts in all nephrology guidelines. However, they are being increasingly used as hemodialysis vascular access. The purpose of this study was to document the natural history of tCVCs and determine the rate and type of catheter replacement. This was a prospective study of 141 patients who underwent hemodialysis with tCVCs between January 2008 and December 2012. The patients used 154 tCVCs. Standard protocols about management of tCVCs, according to European Renal Best Practice, were well established. All catheters were inserted in the internal jugular vein. Criteria for catheter removal were persistent bloodstream infection, detection of an outbreak of catheter-related bloodstream (CRBS) infections, or catheter dysfunction. Event rates were calculated per 1,000 catheter days; tCVC cumulative survival was estimated by Kaplan-Meier analysis. Catheter replacement occurred in 15 patients (0.29 per 1,000 days); catheter dysfunction was the main cause of replacement (0.18 per 1,000 days), typically within 12 months of surgical insertion. A total of 53 CRBS events in 36 patients were identified (0.82 per 1,000 days); 17 organisms, most commonly Gram-positive pathogens, were isolated; 87% of CVC infections were treated by systemic antibiotics associated with lock therapy. tCVC cumulative survival was 91% at 1 year, 88% at 2 years and 85% at 4 years. Our data show a high survival rate of tCVCs in hemodialysis patients, with low incidence of catheter dysfunction and CRBS events. These data justify tCVC use for hemodialysis vascular access, also as first choice, especially in patients with exhausted peripheral access and limited life expectancy.

  12. Intra-oral ignition of monopolar diathermy during transnasal humidified rapid-insufflation ventilatory exchange (THRIVE).

    PubMed

    Onwochei, D; El-Boghdadly, K; Oakley, R; Ahmad, I

    2017-06-01

    We present the case of unanticipated airway ignition during hard palate biopsy. Transnasal humidified rapid-insufflation ventilatory exchange (THRIVE) and monopolar diathermy were utilised for the procedure, during which an arc arose from the diathermy tip to a titanium implant, causing a brief ignition on the monopolar diathermy grip. This case highlights the need for maintained awareness of fire risk when using diathermy in the presence of THRIVE during airway surgery. © 2017 The Association of Anaesthetists of Great Britain and Ireland.

  13. Magnetic catheter manipulation in the interventional MR imaging environment.

    PubMed

    Wilson, Mark W; Martin, Alastair B; Lillaney, Prasheel; Losey, Aaron D; Yee, Erin J; Bernhardt, Anthony; Malba, Vincent; Evans, Lee; Sincic, Ryan; Saeed, Maythem; Arenson, Ronald L; Hetts, Steven W

    2013-06-01

    To evaluate deflection capability of a prototype endovascular catheter, which is remotely magnetically steerable, for use in the interventional magnetic resonance (MR) imaging environment. Copper coils were mounted on the tips of commercially available 2.3-3.0-F microcatheters. The coils were fabricated in a novel manner by plasma vapor deposition of a copper layer followed by laser lithography of the layer into coils. Orthogonal helical (ie, solenoid) and saddle-shaped (ie, Helmholtz) coils were mounted on a single catheter tip. Microcatheters were tested in water bath phantoms in a 1.5-T clinical MR scanner, with variable simultaneous currents applied to the coils. Catheter tip deflection was imaged in the axial plane by using a "real-time" steady-state free precession MR imaging sequence. Degree of deflection and catheter tip orientation were measured for each current application. The catheter tip was clearly visible in the longitudinal and axial planes. Magnetic field artifacts were visible when the orthogonal coils at the catheter tip were energized. Variable amounts of current applied to a single coil demonstrated consistent catheter deflection in all water bath experiments. Changing current polarity reversed the observed direction of deflection, whereas current applied to two different coils resulted in deflection represented by the composite vector of individual coil activations. Microcatheter navigation through the vascular phantom was successful through control of applied current to one or more coils. Controlled catheter deflection is possible with laser lithographed multiaxis coil-tipped catheters in the MR imaging environment. Copyright © 2013 SIR. Published by Elsevier Inc. All rights reserved.

  14. Antibiofilm surface functionalization of catheters by magnesium fluoride nanoparticles

    PubMed Central

    Lellouche, Jonathan; Friedman, Alexandra; Lahmi, Roxanne; Gedanken, Aharon; Banin, Ehud

    2012-01-01

    The ability of bacteria to colonize catheters is a major cause of infection. In the current study, catheters were surface-modified with MgF2 nanoparticles (NPs) using a sonochemical synthesis protocol described previously. The one-step synthesis and coating procedure yielded a homogenous MgF2 NP layer on both the inside and outside of the catheter, as analyzed by high resolution scanning electron microscopy and energy dispersive spectroscopy. The coating thickness varied from approximately 750 nm to 1000 nm on the inner walls and from approximately 450 nm to approximately 580 nm for the outer wall. The coating consisted of spherical MgF2 NPs with an average diameter of approximately 25 nm. These MgF2 NP-modified catheters were investigated for their ability to restrict bacterial biofilm formation. Two bacterial strains most commonly associated with catheter infections, Escherichia coli and Staphylococcus aureus, were cultured in tryptic soy broth, artificial urine and human plasma on the modified catheters. The MgF2 NP-coated catheters were able to significantly reduce bacterial colonization for a period of 1 week compared to the uncoated control. Finally, the potential cytotoxicity of MgF2 NPs was also evaluated using human and mammalian cell lines and no significant reduction in the mitochondrial metabolism was observed. Taken together, our results indicate that the surface modification of catheters with MgF2 NPs can be effective in preventing bacterial colonization and can provide catheters with long-lasting self-sterilizing properties. PMID:22419866

  15. Positioning of nasobiliary tube using magnet-loaded catheters.

    PubMed

    Watanabe, Seitaro; Sato, Takamitsu; Kato, Shingo; Hosono, Kunihiro; Kobayashi, Noritoshi; Nakajima, Atsushi; Kubota, Kensuke

    2013-10-01

    In endoscopic nasobiliary drainage (ENBD), repositioning the catheter from the mouth to the nose is complicated. We devised a method using catheters with magnets and verified its utility and safety. We prospectively enrolled 20 patients undergoing ENBD at Yokohama City University Hospital. The procedures were successful in all 20 cases and no case required a change of operators to a senior doctor. The mean time for the procedure was 36.6 seconds. The emetic reflex was induced 0.5 times on average using the magnet method. The mean X-ray exposure time was 29.6 seconds. No complications occurred. The magnet-loaded catheter method for positioning the ENBD catheter before finally leading it through the nose took little time and was performed successfully and safely. Therefore, the magnet method could become the first choice among techniques for ENBD catheter placement. © Georg Thieme Verlag KG Stuttgart · New York.

  16. Theory of porous catheters and their applications in intraparenchymal infusions.

    PubMed

    Raghavan, Raghu; Odland, Rick M

    2017-01-01

    Multiport catheters and catheters with a porous surface have been proposed for intraparenchymal infusions of therapeutics in fluid suspensions. Target diseases include brain cancer and serious neurodegenerative diseases, as well as peripheral tumors, for example in the prostate and the liver. We set up the theory for infusions from such devices, in particular the fluid flow equations which demand a coupling between the flow within the catheter and that in tissue. (Such a coupling is not necessary in the theory of infusion from single port catheters.) The new feature of such catheters, treated by our model, is revealed by infusions into inhomogeneous media. Multiport designs have the potential to overcome the limitation of single port catheters, for which the path of the fluid leaving the port is dominated by the inhomogeneities. We solve these equations for some simple cases to illustrate the key design features of porous catheters that show such advantages. The mathematics required for numerical solution with more realistic assumptions is also developed. We confirm the robustness of such catheters, when the ports are sufficiently resistive, against leakage paths that would compromise the infusions from catheters with one or a few large ports. The methods of this paper can be incorporated into a larger planning system for intraparenchymal infusions involving such devices.

  17. Semi-automated location identification of catheters in digital chest radiographs

    NASA Astrophysics Data System (ADS)

    Keller, Brad M.; Reeves, Anthony P.; Cham, Matthew D.; Henschke, Claudia I.; Yankelevitz, David F.

    2007-03-01

    Localization of catheter tips is the most common task in intensive care unit imaging. In this work, catheters appearing in digital chest radiographs acquired by portable chest x-rays were tracked using a semi-automatic method. Due to the fact that catheters are synthetic objects, its profile does not vary drastically over its length. Therefore, we use forward looking registration with normalized cross-correlation in order to take advantage of a priori information of the catheter profile. The registration is accomplished with a two-dimensional template representative of the catheter to be tracked generated using two seed points given by the user. To validate catheter tracking with this method, we look at two metrics: accuracy and precision. The algorithms results are compared to a ground truth established by catheter midlines marked by expert radiologists. Using 12 objects of interest comprised of naso-gastric, endo-tracheal tubes, and chest tubes, and PICC and central venous catheters, we find that our algorithm can fully track 75% of the objects of interest, with a average tracking accuracy and precision of 85.0%, 93.6% respectively using the above metrics. Such a technique would be useful for physicians wishing to verify the positioning of catheter tips using chest radiographs.

  18. Effect of heparin bonding on catheter-induced fibrin formation and platelet activation.

    PubMed

    Nichols, A B; Owen, J; Grossman, B A; Marcella, J J; Fleisher, L N; Lee, M M

    1984-11-01

    Pathologic and experimental evidence indicates that platelet activation and fibrin formation contribute to the pathogenesis of angina pectoris, coronary vasospasm and myocardial infarction. Detection of localized intravascular platelet activation and fibrin formation in vivo by selective blood sampling requires catheters that do not induce coagulation ex vivo. We studied the effect of heparin bonding of catheter surfaces on activation of the coagulation system by cardiovascular catheters. Woven Dacron, polyvinylchloride, and polyurethane catheters were tested and compared with identical catheters with heparin-bonded surfaces in 47 patients undergoing percutaneous cardiac catheterization. Platelet activation was measured by radioimmunoassay of plasma platelet factor 4 (PF4), beta-thromboglobulin (BTG), and thromboxane B2 (TXB2) in blood samples withdrawn through catheters, and fibrin formation was assessed by determination of fibrinopeptide A (FPA) levels. In blood samples collected through conventional catheters, FPA, PF4, BTG, and TXB2 levels were markedly elevated; blood sampling through heparin-bonded catheters had no significant effect on FPA, PF4, BTG, or TXB2 levels. Scanning electron microscopy disclosed extensive platelet aggregates and fibrin strands adherent to the surface of conventional catheters but not to heparin-bonded catheter surfaces. This study demonstrates that (1) collection of blood samples through cardiovascular catheters causes artifactual elevation of FPA, PF4, BTG, and TXB2 levels, and (2) heparin-bonded catheter surfaces effectively prevent catheter-induced platelet alpha-granule release and fibrin formation on catheter surfaces. Heparin-bonded catheters will facilitate investigation of the role of intravascular coagulation in coronary artery disease by eliminating catheter-induced fibrin formation and platelet activation.

  19. Humidification on Ventilated Patients: Heated Humidifications or Heat and Moisture Exchangers?

    PubMed Central

    Cerpa, F; Cáceres, D; Romero-Dapueto, C; Giugliano-Jaramillo, C; Pérez, R; Budini, H; Hidalgo, V; Gutiérrez, T; Molina, J; Keymer, J

    2015-01-01

    The normal physiology of conditioning of inspired gases is altered when the patient requires an artificial airway access and an invasive mechanical ventilation (IMV). The endotracheal tube (ETT) removes the natural mechanisms of filtration, humidification and warming of inspired air. Despite the noninvasive ventilation (NIMV) in the upper airways, humidification of inspired gas may not be optimal mainly due to the high flow that is being created by the leakage compensation, among other aspects. Any moisture and heating deficit is compensated by the large airways of the tracheobronchial tree, these are poorly suited for this task, which alters mucociliary function, quality of secretions, and homeostasis gas exchange system. To avoid the occurrence of these events, external devices that provide humidification, heating and filtration have been developed, with different degrees of evidence that support their use. PMID:26312102

  20. Potential in vivo UVC disinfection of catheter lumens: estimation of the doses received by the blood flow outside the catheter tip hole.

    PubMed

    Bak, Jimmy; Jørgensen, Thomas M; Helfmann, Jurgen; Gravemann, Ute; Vorontsova, Inessa

    2011-01-01

    We have demonstrated that it is possible to launch UVC LED light into bacterial contaminated polymer tubes/catheters and disinfect the intraluminal space of these tubes. This can be achieved by UVC treatment of the catheters on a regular basis. Catheters are in the distal end equipped with an exit hole for administration of drugs, bloods or nutrients into the bloodstream. Even if the UVC light is strongly attenuated during its propagation through the catheter tube a fraction of the UVC launched into the catheter will escape through the exit hole and irradiate the blood. We demonstrate by calculations that very small effective doses are exposed to the blood (ca 10(-4) J m(-2)). This dosage level is very low compared with UVC doses reported from other therapeutic applications. The very short residence time of the blood constituents in the irradiated volume in front of the exit hole is the main reason why the UVC exposure to the blood in the catheter application is so low. The very low dose received by the blood through the catheter tip indicated that possible side effects are negligible and makes the UV disinfection technique feasible in a clinical setting. © 2011 Jimmy Bak. Photochemistry and Photobiology © 2011 The American Society of Photobiology.

  1. Urethral catheter insertion forces: a comparison of experience and training.

    PubMed

    Canales, Benjamin K; Weiland, Derek; Reardon, Scott; Monga, Manoj

    2009-01-01

    This study was undertaken to evaluate the insertion forces utilized during simulated placement of a urethral catheter by healthcare individuals with a variety of catheter experience. A 21F urethral catheter was mounted to a metal spring. Participants were asked to press the tubing spring against a force gauge and stop when they met a level of resistance that would typically make them terminate a catheter placement. Simulated catheter insertion was repeated fives times, and peak compression forces were recorded. Healthcare professionals were divided into six groups according to their title: urology staff, non-urology staff, urology resident/ fellow, non-urology resident/ fellow, medical student, and registered nurse. A total of fifty-seven healthcare professionals participated in the study. Urology staff (n = 6) had the lowest average insertion force for any group at 6.8 +/- 2.0 Newtons (N). Medical students (n = 10) had the least amount of experience (1 +/- 0 years) and the highest average insertion force range of 10.1 +/- 3.7 N. Health care workers with greater than 25 years experience used significantly less force during catheter insertions (4.9 +/- 1.8 N) compared to all groups (p < 0.01). We propose the maximum force that should be utilized during urethral catheter insertion is 5 Newtons. This force deserves validation in a larger population and should be considered when designing urethral catheters or creating catheter simulators. Understanding urethral catheter insertion forces may also aid in establishing competency parameters for health care professionals in training.

  2. Videolaparoscopic Catheter Placement Reduces Contraindications to Peritoneal Dialysis

    PubMed Central

    Santarelli, Stefano; Zeiler, Matthias; Monteburini, Tania; Agostinelli, Rosa Maria; Marinelli, Rita; Degano, Giorgio; Ceraudo, Emilio

    2013-01-01

    ♦ Background: Videolaparoscopy is considered the reference method for peritoneal catheter placement in patients with previous abdominal surgery. The placement procedure is usually performed with at least two access sites: one for the catheter and the second for the laparoscope. Here, we describe a new one-port laparoscopic procedure that uses only one abdominal access site in patients not eligible for laparotomic catheter placement. ♦ Method: We carried out one-port laparoscopic placement in 21 patients presenting contraindications to blind surgical procedures because of prior abdominal surgery. This technique consists in the creation of a single mini-laparotomy access through which laparoscopic procedures and placement are performed. The catheter, rectified by an introducer, is inserted inside the port. Subsequently, the port is removed, leaving the catheter in pelvic position. The port is reintroduced laterally to the catheter, confirming or correcting its position. Laparotomic placement was performed in a contemporary group of 32 patients without contraindications to blind placement. Complications and long-term catheter outcome in the two groups were evaluated. ♦ Results: Additional interventions during placement were necessary in 12 patients of the laparoscopy group compared with 5 patients of the laparotomy group (p = 0.002). Laparoscopy documented adhesions in 13 patients, with need for adhesiolysis in 6 patients. Each group had 1 intraoperative complication: leakage in the laparoscopy group, and intestinal perforation in the laparotomy group. During the 2-year follow-up period, laparoscopic revisions had to be performed in 6 patients of the laparoscopy group and in 5 patients of the laparotomy group (p = 0.26). The 1-year catheter survival was similar in both groups. Laparoscopy increased by 40% the number of patients eligible to receive peritoneal dialysis. ♦ Conclusions: Videolaparoscopy placement in patients not eligible for blind surgical

  3. Multicenter Cohort Study to Assess the Impact of a Silver-Alloy and Hydrogel-Coated Urinary Catheter on Symptomatic Catheter-Associated Urinary Tract Infections

    PubMed Central

    Lederer, James W.; Jarvis, William R.; Thomas, Lendon

    2014-01-01

    PURPOSE: The purpose of this study was to determine the effect of a silver-alloy hydrogel catheter on symptomatic catheter-associated urinary tract infections (CAUTIs). DESIGN: Multicenter before-after non-randomized cohort study. SUBJECTS AND SETTING: Seven acute care hospitals ranging in size from 124 to 607 beds participated in this study. The study population included adult patients with a positive urine culture 2 or more days after admission, who underwent Foley catheterization. METHODS: Catheter-associated urinary tract infection surveillance was conducted at each hospital for at least 3 months during the use of a standard catheter and 3 months during the use of the silver-alloy hydrogel catheter. Both the National Healthcare Safety Network (NHSN) surveillance and a clinical definition of CAUTI were used for rate calculation. RESULTS: A 47% relative reduction in the CAUTI rate was observed with the silver-alloy hydrogel catheter compared to the standard catheter when both infection definitions were used (0.945/1000 patient days vs 0.498/1000 patient days) (odds ratio = 0.53; P < .0001; 95% CI: 0.45–0.62). When only NHSN-defined CAUTIs were considered, a 58% relative reduction occurred in the silver-alloy hydrogel period (0.60/1000 patient days vs 0.25/1000 patient days) (odds ratio = 0.42; P < .0001; 95% CI: 0.34–0.53). Antimicrobial days for CAUTIs decreased from 1165 (standard catheter period) to 406 (silver-alloy hydrogel period). CONCLUSIONS: Use of a silver-alloy hydrogel urinary catheter reduced symptomatic CAUTI occurrences as defined by both NHSN and clinical criteria. PMID:24922561

  4. The importance of effective catheter securement.

    PubMed

    Fisher, Jayne

    This article examines the importance of securing/fixing indwelling urinary catheters. The Oxford English dictionary interlinks the two words-'secure' and 'fix'-as having the same meaning. To secure the catheter should not be confused with 'support', whereby the weight of the urine drainage bag is supported with the use of velcro straps or a sleeve. The author introduces the need for the concept of this practice to be at the forefront of nurses' minds in all settings, and this is demonstrated through the use of case studies. Current guidance in this area is reviewed, as well as the problems that can arise when catheters are not secured properly and the available products for health professionals to use.

  5. Interleukin-1beta-induced airway hyperresponsiveness enhances substance P in intrinsic neurons of ferret airway.

    PubMed

    Wu, Z-X; Satterfield, B E; Fedan, J S; Dey, R D

    2002-11-01

    Interleukin (IL)-1beta causes airway inflammation, enhances airway smooth muscle responsiveness, and alters neurotransmitter expression in sensory, sympathetic, and myenteric neurons. This study examines the role of intrinsic airway neurons in airway hyperresponsiveness (AHR) induced by IL-1beta. Ferrets were instilled intratracheally with IL-1beta (0.3 microg/0.3 ml) or saline (0.3 ml) once daily for 5 days. Tracheal smooth muscle contractility in vitro and substance P (SP) expression in tracheal neurons were assessed. Tracheal smooth muscle reactivity to acetylcholine (ACh) and methacholine (MCh) and smooth muscle contractions to electric field stimulation (EFS) both increased after IL-1beta. The IL-1beta-induced AHR was maintained in tracheal segments cultured for 24 h, a procedure that depletes SP from sensory nerves while maintaining viability of intrinsic airway neurons. Pretreatment with CP-99994, an antagonist of neurokinin 1 receptor, attenuated the IL-1beta-induced hyperreactivity to ACh and MCh and to EFS in cultured tracheal segments. SP-containing neurons in longitudinal trunk, SP innervation of superficial muscular plexus neurons, and SP nerve fiber density in tracheal smooth muscle all increased after treatment with IL-1beta. These results show that IL-1beta-enhanced cholinergic airway smooth muscle contractile responses are mediated by the actions of SP released from intrinsic airway neurons.

  6. [Pulmonary rehabilitation after total laryngectomy using a heat and moisture exchanger (HME)].

    PubMed

    Lorenz, K J; Maier, H

    2009-08-01

    A complete removal of the larynx has profound consequences for a patient. Since laryngectomy involves the separation of the upper airway from the lower airway, it not only implies a loss of the voice organ but also leads to chronic lung problems such as increased coughing, mucus production and expectoration. In addition, laryngectomees complain of fatigue, sleeping problems, a reduced sense of smell and taste, and a loss of social contact. A heat and moisture exchanger (HME) cassette can replace a function of the upper airway which consists in conditioning inspired air. It can improve pulmonary symptoms in three ways. 1. An HME cassette heats and moisturises inhaled air and thus creates nearly physiological conditions in the region of the deep airway. 2. The use of an HME cassette leads to an increase in breathing resistance, thereby reducing dynamic airway compression and improving lung ventilation. 3. An HME cassette acts as a filter and removes larger particles from incoming air. This review examines the current understanding of lung physiology after laryngectomy and assesses the effects of HME cassettes on the conditioning of respiratory air, lung function and psychosocial problems. Georg Thieme Verlag KG Stuttgart, New York.

  7. Assessment of a new hub design and the semiquantitative catheter culture method using an in vivo experimental model of catheter sepsis.

    PubMed Central

    Segura, M; Alía, C; Valverde, J; Franch, G; Torres Rodríguez, J M; Sitges-Serra, A

    1990-01-01

    An in vivo model of hub-related catheter sepsis in rabbits is reported. The model was used to investigate the protection offered by a new hub design against external contamination by Pseudomonas aeruginosa or Staphylococcus epidermidis and to reassess the diagnostic value of the semiquantitative culture method in bacteremia of endoluminal origin. Contamination of conventional Luer-Lock connectors was followed by clinical sepsis, positive catheter segment cultures, or both, whereas contamination of the new hub was followed by complete protection. Clinical and bacteriological discrepancies observed between contamination with P. aeruginosa and S. epidermidis suggest that the virulence of microorganisms may account for differences in the natural history of hub-originated catheter sepsis. The semiquantitative extraluminal method for catheter culture yielded less than 15 CFU in three animals with proven bacteremia and should not be used as the "gold standard" to define catheter-related bacteremia. PMID:2254430

  8. Catheter fracture of intravenous ports and its management.

    PubMed

    Wu, Ching-Yang; Fu, Jui-Ying; Feng, Po-Hao; Kao, Tsung-Chi; Yu, Sheng-Yueh; Li, Hao-Jui; Ko, Po-Jen; Hsieh, Hung-Chang

    2011-11-01

    Intravenous ports are widely used for oncology patients. However, catheter fractures may lead to the need for re-intervention. We aimed to identify the risk factors associated with catheter fractures. Between January 1 and December 31, 2006, we retrospectively reviewed the clinical data and plain chest films of 1,505 patients implanted with an intravenous port at Chang Gung Memorial Hospital. Different vascular sites were compared using the chi-square or Fisher's exact test for categorical variables, and the t test was used for continuous variables with normal distribution; P < 0.05 was considered statistically significant. There were 59 and 1,448 procedures in the fracture and non-fracture groups, respectively. Monovariate analysis revealed that the risk factors for catheter fracture were as follows: large angle (P < 0.0001), female gender (P < 0.0008), subclavian route (P < 0.0001), and port type Arrow French (Fr.) 8.1 (P < 0.0001). Because these risk factors showed no interaction effects, they were all considered independent risk factors. When all factors were considered together, all risk factors, except angle and age, retained their statistical significance. Most catheter fractures were caused by material weakness. If catheter fracture is confirmed, further intervention for port and catheter removal is recommended. Female gender, intravenous port implantation via the subclavian route, and the Arrow Fr. 8.1 port were found to be risk factors. Patients with these risk factors should be monitored closely to avoid catheter fractures.

  9. New materials and devices for preventing catheter-related infections

    PubMed Central

    2011-01-01

    Catheters are the leading source of bloodstream infections for patients in the intensive care unit (ICU). Comprehensive unit-based programs have proven to be effective in decreasing catheter-related bloodstream infections (CR-BSIs). ICU rates of CR-BSI higher than 2 per 1,000 catheter-days are no longer acceptable. The locally adapted list of preventive measures should include skin antisepsis with an alcoholic preparation, maximal barrier precautions, a strict catheter maintenance policy, and removal of unnecessary catheters. The development of new technologies capable of further decreasing the now low CR-BSI rate is a major challenge. Recently, new materials that decrease the risk of skin-to-vein bacterial migration, such as new antiseptic dressings, were extensively tested. Antimicrobial-coated catheters can prevent CR-BSI but have a theoretical risk of selecting resistant bacteria. An antimicrobial or antiseptic lock may prevent bacterial migration from the hub to the bloodstream. This review discusses the available knowledge about these new technologies. PMID:21906266

  10. Development of Active Catheter,Active Guide Wire and Micro Sensor Systems

    PubMed Central

    Haga, Y.; Mineta, T.; Totsu, K.; Makishi, W.; Esashi, M.

    2001-01-01

    Summary Active catheters and active guide wires which move like a snake have been developed for catheter-based minimally invasive diagnosis and therapy. Communication and control IC chips in the active catheter reduce the number of lead wires for control. The active catheter can be not only bent but also torsioned and extended. An ultra minature fiber-optic pressure sensor; a forward-looking ultrasonic probe and a magnetic position and orientation sensor have been developed for catheters and guide wires. These moving mechanisms and several sensors which are fitted near the tip of the catheter and the guide wire will provide detailed information near the tip and enable delicate and effective catheter intervention. PMID:20663389

  11. A qualitative study exploring the value of a catheter passport.

    PubMed

    Jaeger, Melanie De; Fox, Fiona; Cooney, Geraldine; Robinson, Jacqueline

    2017-08-10

    Many patients leaving hospital with a catheter do not have sufficient information to self-care and can experience physical and psychological difficulties. This study aimed to explore how a patient-held catheter passport affects the experiences of patients leaving hospital with a urethral catheter, the hospital nurses who discharge them and the community nurses who provide ongoing care for them. Qualitative methods used included interviews, focus groups and questionnaires, and thematic analysis. Three major themes were reported-informing patients, informing nurses; improving catheter care, promoting self-management; and supporting transition. The catheter passport can bridge the existing information gap, improve care, promote self-care and help patients adjust to their catheter, especially if complemented by ongoing input from a nurse or other health professional.

  12. Remote magnetic navigation for circumferential pulmonary vein ablation: single-catheter technique or additional use of a circular mapping catheter?

    PubMed

    Vollmann, Dirk; Lüthje, Lars; Seegers, Joachim; Sohns, Christian; Sossalla, Samuel; Sohns, Jan; Röver, Christian; Hasenfuß, Gerd; Zabel, Markus

    2014-10-01

    Remote magnetic navigation (RMN) is utilized for catheter guidance during pulmonary vein ablation (PVA). We aimed to determine whether the additional use of a circular mapping catheter (CMC) influences efficacy and outcome of RMN-guided PVA. A total of 80 consecutive subjects (65 % male, age 62 ± 9 years) underwent circumferential PVA with a 3D mapping system and an RMN-guided irrigated catheter. Procedural endpoint was complete PV isolation (PVI), total radiofrequency (RF) time >60 min, or procedure duration >5 h. PVI was defined as an entrance and/or exit block, diagnosed with a CMC within the PV ostium or by pacing via the roving RMN-guided catheter (single-catheter technique). Prolonged Holter monitoring after 3 and 6 months was used to detect atrial tachyarrhythmia (AT/AF) recurrences. Complete PVI was achieved in 56 % (45/80) of all subjects (isolated PVs per patient, 3.1 ± 1.2; RF time, 56.3 ± 17.2 min; procedure duration, 3.8 ± 0.8 h). Prospective validation of the single-catheter technique for diagnosing PVI demonstrated high concordance (94 %) with blinded CMC results. CMC use in first-time PVA was associated with similar total RF and procedure times but higher PV isolation rate. Upon multivariate analysis, CMC use, female gender, left PV, smaller PV ostium and repeat PVA predicted PVI during RMN-guided ablation. Persistent AF and mitral regurgitation at baseline and the number of non-isolated PVs predicted AT/AF recurrence during follow-up. Concomitant CMC use for first-time, RMN-guided PVA is associated with similar procedure duration but higher PV isolation rates as compared to a single-catheter approach. Since the number of isolated PVs predicts freedom from AT/AF, CMC utilization appears advisable for first-time, RMN-guided PVA.

  13. Critical role of actin-associated proteins in smooth muscle contraction, cell proliferation, airway hyperresponsiveness and airway remodeling.

    PubMed

    Tang, Dale D

    2015-10-30

    Asthma is characterized by airway hyperresponsiveness and airway remodeling, which are largely attributed to increased airway smooth muscle contractility and cell proliferation. It is known that both chemical and mechanical stimulation regulates smooth muscle contraction. Recent studies suggest that contractile activation and mechanical stretch induce actin cytoskeletal remodeling in smooth muscle. However, the mechanisms that control actin cytoskeletal reorganization are not completely elucidated. This review summarizes our current understanding regarding how actin-associated proteins may regulate remodeling of the actin cytoskeleton in airway smooth muscle. In particular, there is accumulating evidence to suggest that Abelson tyrosine kinase (Abl) plays a critical role in regulating airway smooth muscle contraction and cell proliferation in vitro, and airway hyperresponsiveness and remodeling in vivo. These studies indicate that Abl may be a novel target for the development of new therapy to treat asthma.

  14. Medical catheters thermally manipulated by fiber optic bundles

    DOEpatents

    Chastagner, Philippe

    1992-01-01

    A maneuverable medical catheter comprising a flexible tube having a functional tip. The catheter is connected to a control source. The functional tip of the catheter carries a plurality of temperature activated elements arranged in parallel and disposed about the functional tip and held in spaced relation at each end. These elements expand when they are heated. A plurality of fiber optic bundles, each bundle having a proximal end attached to the control source and a distal end attached to one of the elements carry light into the elements where the light is absorbed as heat. By varying the optic fiber that is carrying the light and the intensity of the light, the bending of the elements can be controlled and thus the catheter steered. In an alternate embodiment, the catheter carries a medical instrument for gathering a sample of tissue. The instrument may also be deployed and operated by thermal expansion and contraction of its moving parts.

  15. Medical catheters thermally manipulated by fiber optic bundles

    DOEpatents

    Chastagner, P.

    1992-10-06

    A maneuverable medical catheter comprising a flexible tube having a functional tip is described. The catheter is connected to a control source. The functional tip of the catheter carries a plurality of temperature activated elements arranged in parallel and disposed about the functional tip and held in spaced relation at each end. These elements expand when they are heated. A plurality of fiber optic bundles, each bundle having a proximal end attached to the control source and a distal end attached to one of the elements carry light into the elements where the light is absorbed as heat. By varying the optic fiber that is carrying the light and the intensity of the light, the bending of the elements can be controlled and thus the catheter steered. In an alternate embodiment, the catheter carries a medical instrument for gathering a sample of tissue. The instrument may also be deployed and operated by thermal expansion and contraction of its moving parts. 10 figs.

  16. Steerable catheter microcoils for interventional MRI reducing resistive heating.

    PubMed

    Bernhardt, Anthony; Wilson, Mark W; Settecase, Fabio; Evans, Leland; Malba, Vincent; Martin, Alastair J; Saeed, Maythem; Roberts, Timothy P L; Arenson, Ronald L; Hetts, Steven W

    2011-03-01

    The aims of this study were to assess resistive heating of microwires used for remote catheter steering in interventional magnetic resonance imaging and to investigate the use of alumina to facilitate heat transfer to saline flowing in the catheter lumen. A microcoil was fabricated using a laser lathe onto polyimide-tipped or alumina-tipped endovascular catheters. In vitro testing was performed on a 1.5-T magnetic resonance system using a vessel phantom, body radiofrequency coil, and steady-state pulse sequence. Resistive heating was measured with water flowing over a polyimide-tip catheter or saline flowing through the lumen of an alumina-tip catheter. Preliminary in vivo testing in porcine common carotid arteries was conducted with normal blood flow or after arterial ligation when current was applied to an alumina-tip catheter for up to 5 minutes. After application of up to 1 W of direct current power, clinically significant temperature increases were noted with the polyimide-tip catheter: 23°C/W at zero flow, 13°C/W at 0.28 cm(3)/s, and 7.9°C/W at 1 cm(3)/s. Using the alumina-tip catheter, the effluent temperature rise using the lowest flow rate (0.12 cm(3)/s) was 2.3°C/W. In vivo testing demonstrated no thermal injury to vessel walls at normal and zero arterial flow. Resistive heating in current carrying wire pairs can be dissipated by saline coolant flowing within the lumen of a catheter tip composed of material that facilitates heat transfer. Copyright © 2011 AUR. Published by Elsevier Inc. All rights reserved.

  17. Thromboresistance Characterization of Extruded Nitric Oxide-Releasing Silicone Catheters

    PubMed Central

    Amoako, Kagya A.; Archangeli, Christopher; Handa, Hitesh; Major, Terry; Meyerhoff, Mark E.; Annich, Gail M.; Bartlett, Robert H.

    2013-01-01

    Intravascular catheters used in clinical practice can activate platelets, leading to thrombus formation and stagnation of blood flow. Nitric oxide (NO)-releasing polymers have been shown previously to reduce clot formation on a number of blood contacting devices. In this work, trilaminar NO-releasing silicone catheters were fabricated and tested for their thrombogenicity. All catheters had specifications of L = 6 cm, inner diameter = 21 gauge (0.0723 cm), outer diameter = 12 gauge (0.2052 cm), and NO-releasing layer thickness = 200 ± 11 μm. Control and NO-releasing catheters were characterized in vitro for their NO flux and NO release duration by gas phase chemiluminescence measurements. The catheters were then implanted in the right and left internal jugular veins of (N = 6 and average weight = 3 kg) adult male rabbits for 4 hours thrombogenicity testing. Platelet counts and function, methemoglobin (metHb), hemoglobin (Hb), and white cell counts and functional time (defined as patency time of catheter) were monitored as measured outcomes. Nitric oxide-releasing catheters (N = 6) maintained an average flux above (2 ± 0.5) × 10−10 mol/min/cm2 for more than 24 hours, whereas controls showed no NO release. Methemoglobin, Hb, white cell, and platelet counts and platelet function at 4 hours were not significantly different from baseline (α = 0.05). However, clots on controls were visibly larger and prevented blood draws at a significantly (p < 0.05) earlier time (2.3 ± 0.7 hours) into the experiment, whereas all NO-releasing catheters survived the entire 4 hours test period. Results indicate that catheter NO flux levels attenuated thrombus formation in a short-term animal model. PMID:22395119

  18. Feedforward Coordinate Control of a Robotic Cell Injection Catheter.

    PubMed

    Cheng, Weyland; Law, Peter K

    2017-08-01

    Remote and robotically actuated catheters are the stepping-stones toward autonomous catheters, where complex intravascular procedures may be performed with minimal intervention from a physician. This article proposes a concept for the positional, feedforward control of a robotically actuated cell injection catheter used for the injection of myogenic or undifferentiated stem cells into the myocardial infarct boundary zones of the left ventricle. The prototype for the catheter system was built upon a needle-based catheter with a single degree of deflection, a 3-D printed handle combined with actuators, and the Arduino microcontroller platform. A bench setup was used to mimic a left ventricle catheter procedure starting from the femoral artery. Using Matlab and the open-source video modeling tool Tracker, the planar coordinates ( y, z) of the catheter position were analyzed, and a feedforward control system was developed based on empirical models. Using the Student's t test with a sample size of 26, it was determined that for both the y- and z-axes, the mean discrepancy between the calibrated and theoretical coordinate values had no significant difference compared to the hypothetical value of µ = 0. The root mean square error of the calibrated coordinates also showed an 88% improvement in the z-axis and 31% improvement in the y-axis compared to the unmodified trial run. This proof of concept investigation leads to the possibility of further developing a feedfoward control system in vivo using catheters with omnidirectional deflection. Feedforward positional control allows for more flexibility in the design of an automated catheter system where problems such as systemic time delay may be a hindrance in instances requiring an immediate reaction.

  19. The effects of electric current on bacteria colonising intravenous catheters.

    PubMed

    Liu, W K; Tebbs, S E; Byrne, P O; Elliott, T S

    1993-11-01

    The effect of a direct electric current (10 microA) on the growth of Staphylococcus aureus, Staphylococcus epidermidis, Escherichia coli, Klebsiella pneumoniae and Proteus mirabilis was investigated. When the ends of negatively-charged intravascular catheters were placed in nutrient agar seeded with bacteria, circular zones of inhibition of bacterial growth were observed around the catheters. The zones ranged from 6 to 16 mm in diameter according to the organism under test. Zones of inhibition were not produced around positively-charged catheters. Bacteria colonising the surfaces of catheters were similarly affected by the application of a 10 microA electric current. A negative electric current applied to colonised catheters for 4 to 24 h significantly reduced the number of adherent viable organisms as compared to controls. The results demonstrated that a constant electric current of low amperage might be used to reduce bacterial colonisation of intravascular catheters. This may offer a novel means of protecting catheters and other prosthetic devices from associated sepsis in vivo.

  20. An intervention to improve the catheter associated urinary tract infection rate in a medical intensive care unit: Direct observation of catheter insertion procedure.

    PubMed

    Galiczewski, Janet M; Shurpin, Kathleen M

    2017-06-01

    Healthcare associated infections from indwelling urinary catheters lead to increased patient morbidity and mortality. The purpose of this study was to determine if direct observation of the urinary catheter insertion procedure, as compared to the standard process, decreased catheter utilization and urinary tract infection rates. This case control study was conducted in a medical intensive care unit. During phase I, a retrospective data review was conducted on utilsiation and urinary catheter infection rates when practitioners followed the institution's standard insertion algorithm. During phase II, an intervention of direct observation was added to the standard insertion procedure. The results demonstrated no change in utilization rates, however, CAUTI rates decreased from 2.24 to 0 per 1000 catheter days. The findings from this study may promote changes in clinical practice guidelines leading to a reduction in urinary catheter utilization and infection rates and improved patient outcomes. Copyright © 2016 Elsevier Ltd. All rights reserved.

  1. A 'Good' muscle in a 'Bad' environment: the importance of airway smooth muscle force adaptation to airway hyperresponsiveness.

    PubMed

    Bossé, Ynuk; Chapman, David G; Paré, Peter D; King, Gregory G; Salome, Cheryl M

    2011-12-15

    Asthma is characterized by airway inflammation, with a consequent increase in spasmogens, and exaggerated airway narrowing in response to stimuli, termed airway hyperresponsiveness (AHR). The nature of any relationship between inflammation and AHR is less clear. Recent ex vivo data has suggested a novel mechanism by which inflammation may lead to AHR, in which increased basal ASM-tone, due to the presence of spasmogens in the airways, may "strengthen" the ASM and ultimately lead to exaggerated airway narrowing. This phenomenon was termed "force adaptation" [Bossé, Y., Chin, L.Y., Paré, P.D., Seow, C.Y., 2009. Adaptation of airway smooth muscle to basal tone: relevance to airway hyperresponsiveness. Am. J. Respir. Cell Mol. Biol. 40, 13-18]. However, it is unknown whether the magnitude of the effect of force adaptation ex vivo could contribute to exaggerated airway narrowing in vivo. Our aim was to utilize a computational model of ASM shortening in order to quantify the potential effect of force adaptation on airway narrowing when all other mechanical factors were kept constant. The shortening in the model is dictated by a balance between physiological loads and ASM force-generating capacity at different lengths. The results suggest that the magnitude of the effect of force adaptation on ASM shortening would lead to substantially more airway narrowing during bronchial challenge at any given airway generation. We speculate that the increased basal ASM-tone in asthma, due to the presence of inflammation-derived spasmogens, produces an increase in the force-generating capacity of ASM, predisposing to AHR during subsequent challenge. Copyright © 2011 Elsevier B.V. All rights reserved.

  2. Mechanotransduction, asthma, and airway smooth muscle

    PubMed Central

    Fabry, Ben; Fredberg, Jeffrey J.

    2008-01-01

    Excessive force generation by airway smooth muscle is the main culprit in excessive airway narrowing during an asthma attack. The maximum force the airway smooth muscle can generate is exquisitely sensitive to muscle length fluctuations during breathing, and is governed by complex mechanotransduction events that can best be studied by a hybrid approach in which the airway wall is modeled in silico so as to set a dynamic muscle load comparable to that experienced in vivo. PMID:18836522

  3. Cardiovascular causes of airway compression.

    PubMed

    Kussman, Barry D; Geva, Tal; McGowan, Francis X

    2004-01-01

    Compression of the paediatric airway is a relatively common and often unrecognized complication of congenital cardiac and aortic arch anomalies. Airway obstruction may be the result of an anomalous relationship between the tracheobronchial tree and vascular structures (producing a vascular ring) or the result of extrinsic compression caused by dilated pulmonary arteries, left atrial enlargement, massive cardiomegaly, or intraluminal bronchial obstruction. A high index of suspicion of mechanical airway compression should be maintained in infants and children with recurrent respiratory difficulties, stridor, wheezing, dysphagia, or apnoea unexplained by other causes. Prompt diagnosis is required to avoid death and minimize airway damage. In addition to plain chest radiography and echocardiography, diagnostic investigations may consist of barium oesophagography, magnetic resonance imaging (MRI), computed tomography, cardiac catheterization and bronchoscopy. The most important recent advance is MRI, which can produce high quality three-dimensional reconstruction of all anatomic elements allowing for precise anatomic delineation and improved surgical planning. Anaesthetic technique will depend on the type of vascular ring and the presence of any congenital heart disease or intrinsic lesions of the tracheobronchial tree. Vascular rings may be repaired through a conventional posterolateral thoracotomy, or utilizing video-assisted thoracoscopic surgery (VATS) or robotic endoscopic surgery. Persistent airway obstruction following surgical repair may be due to residual compression, secondary airway wall instability (malacia), or intrinsic lesions of the airway. Simultaneous repair of cardiac defects and vascular tracheobronchial compression carries a higher risk of morbidity and mortality.

  4. Candida tropicalis biofilms: artificial urine, urinary catheters and flow model.

    PubMed

    Negri, Melyssa; Silva, Sónia; Henriques, Mariana; Azeredo, Joana; Svidzinski, Terezinha; Oliveira, Rosário

    2011-10-01

    Adhesion to medical devices and biofilm formation are considered important virulence factors of Candida tropicalis. This work aimed to use artificial urine (AU) and urinary catheters, under flow conditions, for studying C. tropicalis biofilms. Adhesion and biofilm formation on silicone and latex urinary catheters were quantified by crystal violet staining and determination of colony forming units. Candida surface hydrophobicity was also evaluated, as well as the biofilms' matrix content in terms of proteins and carbohydrates. Candida tropicalis was able to adhere and to form biofilms along the entire length of the catheters under flow conditions. It was found that the isolate U69 adhered significantly more to both types of catheters than did the reference strain. However, U69 biofilms contained significantly less cultivable cells and higher biofilm biomass than those of the reference strain. Detachment of cells from biofilms on latex catheter was lower compared to silicone catheter. This model using AU appeared to be suitable for studies mimicking the real body conditions. Additionally, C. tropicalis was in fact able to colonize urinary catheters in the presence of AU and to detach from these catheters, demonstrating their capacity to colonize distal sites.

  5. 21 CFR 868.2600 - Airway pressure monitor.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Airway pressure monitor. 868.2600 Section 868.2600...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Monitoring Devices § 868.2600 Airway pressure monitor. (a) Identification. An airway pressure monitor is a device used to measure the pressure in a patient's upper airway...

  6. Choline deficiency is associated with increased risk for venous catheter thrombosis.

    PubMed

    Buchman, Alan L; Ament, Marvin E; Jenden, Donald J; Ahn, Chul

    2006-01-01

    Patients with intestinal failure who require long-term parenteral nutrition (PN) develop catheter thrombosis as a complication. This patient group may also develop choline deficiency because of a defect in the hepatic transsulfuration pathway in the setting of malabsorption. This study was undertaken to determine whether choline deficiency is a risk factor for development of catheter thrombosis. Plasma free and phospholipid-bound choline concentrations were measured in a group of 41 patients that required long-term PN. Episodes of catheter thrombosis from onset of PN to the time of blood testing were recorded. Sixteen (39%) patients developed catheter thrombosis, and 5 of these had recurrent catheter thrombosis. Plasma free choline was 7.7 +/- 2.7 nmol/mL in patients with no history of catheter thrombosis and 6.2 +/- 1.7 nmol/mL in patients with previous catheter thrombosis (p = .076 by Wilcoxon rank-sum test). The partial correlation between plasma free choline concentration and the frequency of clots after controlling for catheter duration was r = -0.33 (p = .038). The relative risk for catheter thrombosis in subjects with a plasma free choline concentration <8 nmol/mL was 10.0, 95% confidence interval (1.134-88.167). Plasma phospholipid-bound choline concentration was 2191.7 +/- 679.0 nmol/mL in patients with previous catheter thrombosis and 2103.3 +/- 531.2 nmol/mL in patients without history of catheter thrombosis (p = NS). Choline deficiency is a significant risk factor for development of catheter thrombosis in patients with intestinal failure who require PN.

  7. Central venous catheter-related bloodstream infections in the intensive care unit

    PubMed Central

    Patil, Harsha V.; Patil, Virendra C.; Ramteerthkar, M. N.; Kulkarni, R. D.

    2011-01-01

    Context: Central venous catheter-related bloodstream infection (CRBSI) is associated with high rates of morbidity and mortality in critically ill patients. Aims: This study was conducted to determine the incidence of central venous catheter-related infections (CRIs) and to identify the factors influencing it. So far, there are very few studies that have been conducted on CRBSI in the intensive care unit in India. Settings and Design: This was a prospective, observational study carried out in the medical intensive care unit (MICU) over a period of 1 year from January to December 2004. Materials and Methods: A total of 54 patients with indwelling central venous catheters of age group between 20 and 75 years were included. The catheters were cultured using the standard semiquantitative culture (SQC) method. Statistical analysis used SPSS-10 version statistical software. Results: A total of 54 CVC catheters with 319 catheter days were included in this study. Of 54 patients with CVCs studied for bacteriology, 39 (72.22%) catheters showed negative SQCs and also negative blood cultures. A total of 15 (27.77%) catheters were positive on SQC, of which 10 (18.52%) were with catheter-associated infection and four (7.41%) were with catheter-associated bacteremia; the remaining one was a probable catheter-associated bacteremia. CRIs were high among catheters that were kept in situ for more than 3 days and emergency procedures where two or more attempts were required for catheterization (P < 0.05). In multivariate analysis of covariance duration of catheter in situ for >3 days, inexperienced venupucturist, more number of attempts and emergency CVC were associated with more incidence of CVCBSIs, with P <0.02. The duration of catheter in situ was negatively correlated (-0.53) and number of attempts required to put CVC was positively correlated (+0.39) with incidence of CVCBSIs. Sixty-five percent of the isolates belonged to the CONS group (13/20). Staphylococcus epidermidis showed

  8. Airway structure and function in Eisenmenger's syndrome.

    PubMed

    McKay, K O; Johnson, P R; Black, J L; Glanville, A R; Armour, C L

    1998-10-01

    The responsiveness of airways from patients with Eisenmenger's syndrome (n = 5) was compared with that in airways from organ donors (n = 10). Enhanced contractile responses to cholinergic stimulation were found in airways from patients with Eisenmenger's syndrome. The maximal responses to acetylcholine, carbachol, and parasympathetic nerve stimulation in airway tissue from these patients were 221%, 139%, and 152%, respectively, of the maximal responses obtained in donor tissue. Further, relaxation responses to isoproterenol and levocromakalim were absent (n = 2) or markedly impaired (n = 3) in airways from patients with Eisenmenger's syndrome. This attenuated relaxation response was nonspecific in that it was also absent after vasoactive intestinal peptide, sodium nitroprusside, papaverine, and electrical field application. These observations can most likely be explained by a decrease in intrinsic smooth muscle tone, as precontraction of airways revealed relaxation responses that were equivalent to those obtained in donor tissues. Morphometric analysis of tissues used for the functional studies revealed no differences in the airway dimensions (internal perimeter) or airway wall components (e.g., smooth muscle, cartilage) or total area to explain these observations. Although the mechanism for this observed decrease in intrinsic airway smooth muscle tone is not certain, it may be due to alteration in the substructure of the airway wall or, alternatively, may result from the continued release of depressant factors in the vicinity of the smooth muscle which permanently alters smooth muscle responsiveness.

  9. A meta-analysis of prehospital airway control techniques part II: alternative airway devices and cricothyrotomy success rates.

    PubMed

    Hubble, Michael W; Wilfong, Denise A; Brown, Lawrence H; Hertelendy, Attila; Benner, Randall W

    2010-01-01

    Airway management is a key component of prehospital care for seriously ill and injured patients. Oral endotracheal intubation (OETI) is the definitive airway of choice in most emergency medical services (EMS) systems. However, OETI may not be an approved skill for some clinicians or may prove problematic in certain patients because of anatomic abnormalities, trauma, or inadequate relaxation. In these situations alternative airways are frequently employed. However, the reported success rates for these devices vary widely, and established benchmarks are lacking. We sought to determine pooled estimates of the success rates of alternative airway devices (AADs) and needle cricothyrotomy (NCRIC) and surgical cricothyrotomy (SCRIC) placement through a meta-analysis of the literature. We performed a systematic literature search for all English-language articles reporting success rates for AADs, SCRIC, and NCRIC. Studies of field procedures performed by prehospital personnel from any nation were included. All titles were reviewed independently by two authors using prespecified inclusion criteria. Pooled estimates of success rates for each airway technique were calculated using a random-effects meta-analysis model. Of 2,005 prehospital airway titles identified, 35 unique studies were retained for analysis of AAD success rates, encompassing a total of 10,172 prehospital patients. The success rates for SCRIC and NCRIC were analyzed across an additional 21 studies totaling 512 patients. The pooled estimates (and 95% confidence intervals [CIs]) for intervention success across all clinicians and patients were as follows: esophageal obturator airway-esophageal gastric tube airway (EOA-EGTA) 92.6% (90.1%-94.5%); pharyngeotracheal lumen airway (PTLA) 82.1% (74.0%-88.0%); esophageal-tracheal Combitube (ETC) 85.4% (77.3%-91.0%); laryngeal mask airway (LMA) 87.4% (79.0%-92.8%); King Laryngeal Tube airway (King LT) 96.5% (71.2%-99.7%); NCRIC 65.8% (42.3%-83.59%); and SCRIC 90.5% (84

  10. Heat and moisture exchanger: importance of humidification in anaesthesia and ventilatory breathing system.

    PubMed

    Parmar, Vandana

    2008-08-01

    Adequate humidification is vital to maintain homeostasis of the airway. Heat and moisture exchangers conserve some of the exhaled water, heat and return them to inspired gases. Many heat and moisture exchangers also perfom bacterial/viral filtration and prevent inhalation of small particles. Heat and moisture exchangers are also called condenser humidifier, artificial nose, etc. Most of them are disposable devices with exchanging medium enclosed in a plastic housing. For adult and paediatric age group different dead space types are available. Heat and moisture exchangers are helpful during anaesthesia and ventilatory breathing system. To reduce the damage of the upper respiratory tract through cooling and dehydration inspiratory air can be heated and humidified, thus preventing the serious complications.

  11. Catheter-related sepsis due to Rhodotorula glutinis.

    PubMed

    Hsueh, Po-Ren; Teng, Lee-Jene; Ho, Shen-Wu; Luh, Kwen-Tay

    2003-02-01

    We describe a central venous catheter-related (Port-A-Cath; Smiths Industries Medical Systems [SIMS] Deltec, Inc., St. Paul, Minn.) infection caused by Rhodotorula glutinis in a 51-year-old man with nasopharyngeal carcinoma. He was treated with fluconazole for 8 weeks and had the catheter removed. Two isolates of R. glutinis recovered from blood specimens (one obtained via peripheral veins and one via the catheter) before administration of fluconazole and one recovered from the removed catheter 17 days after initiation of fluconazole therapy exhibited high-level resistance to fluconazole (MICs, >256 microg/ml). These three isolates were found to belong to a single clone on the basis of identical antibiotypes determined by the E test (PDM Epsilometer; AB Biodisk, Solna, Sweden) and biotypes determined by API ID32 C (bioMerieux, Marcy I'Etoile, France) and their identical random amplified polymorphic DNA patterns.

  12. Catheter-Related Sepsis Due to Rhodotorula glutinis

    PubMed Central

    Hsueh, Po-Ren; Teng, Lee-Jene; Ho, Shen-Wu; Luh, Kwen-Tay

    2003-01-01

    We describe a central venous catheter-related (Port-A-Cath; Smiths Industries Medical Systems [SIMS] Deltec, Inc., St. Paul, Minn.) infection caused by Rhodotorula glutinis in a 51-year-old man with nasopharyngeal carcinoma. He was treated with fluconazole for 8 weeks and had the catheter removed. Two isolates of R. glutinis recovered from blood specimens (one obtained via peripheral veins and one via the catheter) before administration of fluconazole and one recovered from the removed catheter 17 days after initiation of fluconazole therapy exhibited high-level resistance to fluconazole (MICs, >256 μg/ml). These three isolates were found to belong to a single clone on the basis of identical antibiotypes determined by the E test (PDM Epsilometer; AB Biodisk, Solna, Sweden) and biotypes determined by API ID32 C (bioMerieux, Marcy I'Etoile, France) and their identical random amplified polymorphic DNA patterns. PMID:12574300

  13. Use of asymmetric bidirectional catheters with different curvature radius for catheter ablation of cardiac arrhythmias.

    PubMed

    Mantziari, Lilian; Suman-Horduna, Irina; Gujic, Marko; Jones, David G; Wong, Tom; Markides, Vias; Foran, John P; Ernst, Sabine

    2013-06-01

    The impact of recently introduced asymmetric bidirectional ablation catheters on procedural parameters and acute success rates of ablation procedures is unknown. We retrospectively analyzed data regarding ablations using a novel bidirectional catheter in a tertiary cardiac center and compared these in 1:5 ratio with a control group of procedures matched for age, gender, operator, and ablation type. A total of 50 cases and 250 controls of median age 60 (50-68) years were studied. Structural heart disease was equally prevalent in both groups (39%) while history of previous ablations was more common in the study arm (54% vs 30%, P = 0.001). Most of the ablation cases were for atrial fibrillation (46%), followed by atrial tachycardia (28%), supraventricular tachycardia (12%), and ventricular tachycardia (14%). Median procedure duration was 128 (52-147) minutes with the bidirectional, versus 143 (105-200) minutes with the conventional catheter (P = 0.232), and median fluoroscopy time was 17 (10-34) minutes versus 23 (12-39) minutes, respectively (P = 0.988). There was a trend toward a lower procedure duration for the atrial tachycardia ablations, 89 (52-147) minutes versus 130 (100-210) minutes, P = 0.064. The procedure was successfully completed in 96% of the bidirectional versus 84% of the control cases (P = 0.151). A negative correlation was observed between the relative fluoroscopy duration and the case number (r = -0.312, P = 0.028), reflecting the learning curve for the bidirectional catheter. The introduction of the bidirectional catheter resulted in no prolongation of procedure parameters and similar success rates, while there was a trend toward a lower procedure duration for atrial tachycardia ablations. ©2013, The Authors. Journal compilation ©2013 Wiley Periodicals, Inc.

  14. Number and location of drainage catheter side holes: in vitro evaluation.

    PubMed

    Ballard, D H; Alexander, J S; Weisman, J A; Orchard, M A; Williams, J T; D'Agostino, H B

    2015-09-01

    To evaluate the influence of number and location of catheter shaft side holes regarding drainage efficiency in an in vitro model. Three different drainage catheter models were constructed: open-ended model with no side holes (one catheter), unilateral side hole model (six catheters with one to six unilateral side holes), and bilateral side hole model (six catheters with one to six bilateral side holes). Catheters were inserted into a drainage output-measuring device with a constant-pressure reservoir of water. The volume of water evacuated by each of the catheters at 10-second intervals was measured. A total of five trials were performed for each catheter. Data were analysed using one-way analysis of variance. The open-ended catheter had a mean drainage volume comparable to the unilateral model catheters with three, four, and five side holes. Unilateral model catheters had significant drainage volume increases up to three side holes; unilateral model catheters with more than three side holes had no significant improvement in drainage volume. All bilateral model catheters had significantly higher mean drainage volumes than their unilateral counterparts. There was no significant difference between the mean drainage volume with one, two, or three pairs of bilateral side holes. Further, there was no drainage improvement by adding additional bilateral side holes. The present in vitro study suggests that beyond a critical side hole number threshold, adding more distal side holes does not improve catheter drainage efficiency. These results may be used to enhance catheter design towards improving their drainage efficiency. Copyright © 2015 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  15. Diagnostic procedures for catheter malfunction in programmable implantable intraperitoneal insulin infusion devices.

    PubMed

    Olsen, C L; Turner, D S; Iravani, M; Waxman, K; Selam, J L; Charles, M A

    1995-01-01

    To evaluate the roles of 1) abdominal radiography, 2) a pressure diagnostic procedure (PDP) using a standardized diluent infusion into the catheter sideport, and 3) radiocontrast imaging of the catheter lumen as procedures for diagnosing catheter malfunction in diabetic patients implanted with a programmable intraperitoneal infusion device. Sixteen type I diabetic patients implanted with Infusaid programmable intraperitoneal insulin pumps were studied. The ability of the above three procedures to assist diagnosis of catheter malfunction and distinguish between occlusion and catheter breakage was retrospectively analyzed. Glycated hemoglobin was measured to determine the clinical importance of catheter malfunctions and decreases in pump flow due to insulin aggregation in the pump chamber. Mean glycated hemoglobin levels increased significantly from 8.0 +/- 0.3 to 9.0 +/- 0.4% (P < 0.05) before and after catheter malfunction, but not during pump flow slowdowns. Mean peak pressure during PDP was 1.96 +/- 0.14 psi (P < 0.01 vs. normal) in reversibly occluded catheters and 1.86 +/- 0.35 psi (P < 0.05 vs. normal) in broken catheters, compared with 1.32 +/- 0.23 psi in normal catheters. Decay times during PDP were > 50 s for both reversibly occluded and broken catheters (P < 0.001 vs. normal of 3.6 +/- 0.82 s). Abdominal radiographs and sideport injections of contrast material were used to distinguish the types of broken catheters. Catheter breakage and occlusion are complications in implantable insulin infusion systems and result in metabolic deterioration. The presence of a sideport allows pressure data and radiographic procedures to assist in determining the cause of catheter malfunction. A diagnostic algorithm was generated to improve efficiency in investigating catheter problems.

  16. Dynamics of Gas Exchange through the Fractal Architecture of the Human Lung, Modeled as an Exactly Solvable Hierarchical Tree

    NASA Astrophysics Data System (ADS)

    Mayo, Michael; Pfeifer, Peter; Gheorghiu, Stefan

    2008-03-01

    The acinar airways lie at the periphery of the human lung and are responsible for the transfer of oxygen from air to the blood during respiration. This transfer occurs by the diffusion-reaction of oxygen over the irregular surface of the alveolar membranes lining the acinar airways. We present an exactly solvable diffusion-reaction model on a hierarchically branched tree, allowing a quantitative prediction of the oxygen current over the entire system of acinar airways responsible for the gas exchange. We discuss the effect of diffusional screening, which is strongly coupled to oxygen transport in the human lung. We show that the oxygen current is insensitive to a loss of permeability of the alveolar membranes over a wide range of permeabilities, similar to a ``constant-current source'' in an electric network. Such fault tolerance has been observed in other treatments of the gas exchange in the lung and is obtained here as a fully analytical result.

  17. Suprapubic catheter care

    MedlinePlus

    ... going back into your bladder. Try not to disconnect the catheter more than you need to. Keeping ... Copyright Privacy Accessibility Quality Guidelines Viewers & Players MedlinePlus Connect for EHRs For Developers U.S. National Library of ...

  18. Investigating the geometry of pig airways using computed tomography

    NASA Astrophysics Data System (ADS)

    Mansy, Hansen A.; Azad, Md Khurshidul; McMurray, Brandon; Henry, Brian; Royston, Thomas J.; Sandler, Richard H.

    2015-03-01

    Numerical modeling of sound propagation in the airways requires accurate knowledge of the airway geometry. These models are often validated using human and animal experiments. While many studies documented the geometric details of the human airways, information about the geometry of pig airways is scarcer. In addition, the morphology of animal airways can be significantly different from that of humans. The objective of this study is to measure the airway diameter, length and bifurcation angles in domestic pigs using computed tomography. After imaging the lungs of 3 pigs, segmentation software tools were used to extract the geometry of the airway lumen. The airway dimensions were then measured from the resulting 3 D models for the first 10 airway generations. Results showed that the size and morphology of the airways of different animals were similar. The measured airway dimensions were compared with those of the human airways. While the trachea diameter was found to be comparable to the adult human, the diameter, length and branching angles of other airways were noticeably different from that of humans. For example, pigs consistently had an early airway branching from the trachea that feeds the superior (top) right lung lobe proximal to the carina. This branch is absent in the human airways. These results suggested that the human geometry may not be a good approximation of the pig airways and may contribute to increasing the errors when the human airway geometric values are used in computational models of the pig chest.

  19. Effect of airway acidosis and alkalosis on airway vascular smooth muscle responsiveness to albuterol.

    PubMed

    Cancado, Jose E; Mendes, Eliana S; Arana, Johana; Horvath, Gabor; Monzon, Maria E; Salathe, Matthias; Wanner, Adam

    2015-04-02

    In vitro and animal experiments have shown that the transport and signaling of β2-adrenergic agonists are pH-sensitive. Inhaled albuterol, a hydrophilic β2-adrenergic agonist, is widely used for the treatment of obstructive airway diseases. Acute exacerbations of obstructive airway diseases can be associated with changes in ventilation leading to either respiratory acidosis or alkalosis thereby affecting albuterol responsiveness in the airway. The purpose of this study was to determine if airway pH has an effect on albuterol-induced vasodilation in the airway. Ten healthy volunteers performed the following respiratory maneuvers: quiet breathing, hypocapnic hyperventilation, hypercapnic hyperventilation, and eucapnic hyperventilation (to dissociate the effect of pH from the effect of ventilation). During these breathing maneuvers, exhaled breath condensate (EBC) pH and airway blood flow response to inhaled albuterol (ΔQ̇aw) were assessed. Mean ± SE EBC pH (units) and ΔQ̇aw (μl.min(-1).mL(-1)) were 6.4 ± 0.1 and 16.8 ± 1.9 during quiet breathing, 6.3 ± 0.1 and 14.5 ± 2.4 during eucapnic hyperventilation, 6.6 ± 0.2 and -0.2 ± 1.8 during hypocapnic hyperventilation (p = 0.02 and <0.01 vs. quiet breathing), and 5.9 ± 0.1 and 2.0 ± 1.5 during hypercapnic hyperventilation (p = 0.02 and <0.02 vs quiet breathing). Albuterol responsiveness in the airway as assessed by ΔQ̇aw is pH sensitive. The breathing maneuver associated with decreased and increased EBC pH both resulted in a decreased responsiveness independent of the level of ventilation. These findings suggest an attenuated response to hydrophilic β2-adrenergic agonists during airway disease exacerbations associated with changes in pH. Registered at clinicaltrials.gov: NCT01216748 .

  20. Modeling bronchial circulation with application to soluble gas exchange: description and sensitivity analysis.

    PubMed

    Bui, T D; Dabdub, D; George, S C

    1998-06-01

    The steady-state exchange of inert gases across an in situ canine trachea has recently been shown to be limited equally by diffusion and perfusion over a wide range (0.01-350) of blood solubilities (betablood; ml . ml-1 . atm-1). Hence, we hypothesize that the exchange of ethanol (betablood = 1,756 at 37 degrees C) in the airways depends on the blood flow rate from the bronchial circulation. To test this hypothesis, the dynamics of the bronchial circulation were incorporated into an existing model that describes the simultaneous exchange of heat, water, and a soluble gas in the airways. A detailed sensitivity analysis of key model parameters was performed by using the method of Latin hypercube sampling. The model accurately predicted a previously reported experimental exhalation profile of ethanol (R2 = 0.991) as well as the end-exhalation airstream temperature (34.6 degrees C). The model predicts that 27, 29, and 44% of exhaled ethanol in a single exhalation are derived from the tissues of the mucosa and submucosa, the bronchial circulation, and the tissue exterior to the submucosa (which would include the pulmonary circulation), respectively. Although the concentration of ethanol in the bronchial capillary decreased during inspiration, the three key model outputs (end-exhaled ethanol concentration, the slope of phase III, and end-exhaled temperature) were all statistically insensitive (P > 0.05) to the parameters describing the bronchial circulation. In contrast, the model outputs were all sensitive (P < 0.05) to the thickness of tissue separating the core body conditions from the bronchial smooth muscle. We conclude that both the bronchial circulation and the pulmonary circulation impact soluble gas exchange when the entire conducting airway tree is considered.

  1. Motorcycle exhaust particles induce airway inflammation and airway hyperresponsiveness in BALB/C mice.

    PubMed

    Lee, Chen-Chen; Liao, Jiunn-Wang; Kang, Jaw-Jou

    2004-06-01

    A number of large studies have reported that environmental pollutants from fossil fuel combustion can cause deleterious effects to the immune system, resulting in an allergic reaction leading to respiratory tract damage. In this study, we investigated the effect of motorcycle exhaust particles (MEP), a major pollutant in the Taiwan urban area, on airway inflammation and airway hyperresponsiveness in laboratory animals. BALB/c mice were instilled intratracheally (i.t.) with 1.2 mg/kg and 12 mg/kg of MEP, which was collected from two-stroke motorcycle engines. The mice were exposed 3 times i.t. with MEP, and various parameters for airway inflammation and hyperresponsiveness were sequentially analyzed. We found that MEP would induce airway and pulmonary inflammation characterized by infiltration of eosinophils, neutrophils, lymphocytes, and macrophages in bronchoalveolar lavage fluid (BALF) and inflammatory cell infiltration in lung. In addition, MEP treatment enhanced BALF interleukin-4 (IL-4), IL-5, and interferon-gamma (IFN-gamma) cytokine levels and serum IgE production. Bronchial response measured by unrestrained plethysmography with methacholine challenge showed that MEP treatment induced airway hyperresponsiveness (AHR) in BALB/c mice. The chemical components in MEP were further fractionated with organic solvents, and we found that the benzene-extracted fraction exerts a similar biological effect as seen with MEP, including airway inflammation, increased BALF IL-4, serum IgE production, and induction of AHR. In conclusion, we present evidence showing that the filter-trapped particles emitted from the unleaded-gasoline-fueled two-stroke motorcycle engine may induce proinflammatory and proallergic response profiles in the absence of exposure to allergen.

  2. Three-Catheter Technique for Ablation of Left-Sided Accessory Pathways in Wolff-Parkinson-White is Less Expensive and Equally Successful When Compared to a Five-Catheter Technique.

    PubMed

    Capone, Christine A; Ceresnak, Scott R; Nappo, Lynn; Gates, Gregory J; Schechter, Clyde B; Pass, Robert H

    2015-12-01

    To compare the efficacy, safety, and cost-effectiveness of a three-catheter approach with a conventional five-catheter approach for the mapping and ablation of supraventricular tachycardia in pediatric patients with Wolff-Parkinson-White Syndrome (WPW) and concealed accessory pathways (APs). A retrospective review from 2008 to 2012 of patients less than 21 years with WPW who underwent a three-catheter radiofrequency (RF) ablation of a left-sided AP (ablation, right ventricular [RV] apical, and coronary sinus [CS] decapolar catheters) was performed. The three-catheter group was compared to a control group who underwent a standard five-catheter (ablation, RV apical, CS decapolar, His catheter, and right atrial catheter) ablation for the treatment of left-sided WPW or concealed AP. Demographics, ablation outcomes, and costs were compared between groups. Twenty-eight patients met inclusion criteria with 28 control patients. The groups did not differ in gender, age, weight, or body surface area. Locations of the AP on the mitral annulus were similar between the groups. All patients were ablated via transseptal approach. Note that 28 of 28 in the three-catheter group (100%) and 27 of 28 (96%) controls were acutely successfully ablated (P = 0.31). No complications were encountered. There was no difference in procedural time, time to loss of AP conduction, or number of RF applications. Use of the three-catheter technique resulted in a total savings of $2,465/case, which includes the $680 savings from using fewer catheters as well as the savings from a shortened procedure time. Ablation in patients with WPW and a left-sided AP can be performed using three catheters with similar efficacy and safety while offering significant cost savings compared to a conventional five-catheter approach. © 2015 Wiley Periodicals, Inc.

  3. Brain-Derived Neurotrophic Factor in the Airways

    PubMed Central

    Prakash, Y.S.; Martin, Richard J.

    2014-01-01

    In addition to their well-known roles in the nervous system, there is increasing recognition that neurotrophins such as brain derived neurotrophic factor (BDNF) as well as their receptors are expressed in peripheral tissues including the lung, and can thus potentially contribute to both normal physiology and pathophysiology of several diseases. The relevance of this family of growth factors lies in emerging clinical data indicating altered neurotrophin levels and function in a range of diseases including neonatal and adult asthma, sinusitis, influenza, and lung cancer. The current review focuses on 1) the importance of BDNF expression and signaling mechanisms in early airway and lung development, critical to both normal neonatal lung function and also its disruption in prematurity and insults such as inflammation and infection; 2) how BDNF, potentially derived from airway nerves modulate neurogenic control of airway tone, a key aspect of airway reflexes as well as dysfunctional responses to allergic inflammation; 3) the emerging idea that local BDNF production by resident airway cells such as epithelium and airway smooth muscle can contribute to normal airway structure and function, and to airway hyperreactivity and remodeling in diseases such as asthma. Furthermore, given its pleiotropic effects in the airway, BDNF may be a novel and appealing therapeutic target. PMID:24560686

  4. Sequential Stenting for Extensive Malignant Airway Stenosis

    PubMed Central

    Takahama, Makoto; Nakajima, Ryu; Kimura, Michitaka; Tei, Keiko; Yamamoto, Ryoji

    2014-01-01

    Purpose: Malignant airway stenosis extending from the bronchial bifurcation to the lower lobar orifice was treated with airway stenting. We herein examine the effectiveness of airway stenting for extensive malignant airway stenosis. Methods: Twelve patients with extensive malignant airway stenosis underwent placement of a silicone Dumon Y stent (Novatech, La Ciotat, France) at the tracheal bifurcation and a metallic Spiral Z-stent (Medico’s Hirata, Osaka, Japan) at either distal side of the Y stent. We retrospectively analyzed the therapeutic efficacy of the sequential placement of these silicone and metallic stents in these 12 patients. Results: The primary disease was lung cancer in eight patients, breast cancer in two patients, tracheal cancer in one patient, and thyroid cancer in one patient. The median survival period after airway stent placement was 46 days. The Hugh–Jones classification and performance status improved in nine patients after airway stenting. One patient had prolonged hemoptysis and died of respiratory tract hemorrhage 15 days after the treatment. Conclusion: Because the initial disease was advanced and aggressive, the prognosis after sequential airway stent placement was significantly poor. However, because respiratory distress decreased after the treatment in most patients, this treatment may be acceptable for selected patients with extensive malignant airway stenosis. PMID:25273272

  5. Malignant central airway obstruction

    PubMed Central

    Mudambi, Lakshmi; Miller, Russell

    2017-01-01

    This review comprehensively describes recent advances in the management of malignant central airway obstruction (CAO). Malignant CAO can be a dramatic and devastating manifestation of primary lung cancer or metastatic disease. A variety of diagnostic modalities are available to provide valuable information to plan a therapeutic intervention. Clinical heterogeneity in the presentation of malignant CAO provides opportunities to adapt and utilize endoscopic technology and tools in many ways. Mechanical debulking, thermal tools, cryotherapy and airway stents are methods and instruments used to rapidly restore airway patency. Delayed bronchoscopic methods, such as photodynamic therapy (PDT) and brachytherapy can also be utilized in specific non-emergent situations to establish airway patency. Although data regarding the success and complications of therapeutic interventions are retrospective and characterized by clinical and outcome measure variability, the symptoms of malignant CAO can often be successfully palliated. Assessment of risks and benefits of interventions in each individual patient during the decision-making process forms the critical foundation of the management of malignant CAO. PMID:29214067

  6. Catheter-associated UTI

    MedlinePlus

    ... UTI; Health care-associated UTI; Catheter-associated bacteriuria; Hospital acquired-UTI Images Bladder catheterization, female Bladder catheterization, male References Calfee DP. Prevention and control of health care-associated infections. In: Goldman L, Schafer AI, eds. Goldman's Cecil ...

  7. Regulation of human airway surface liquid.

    PubMed

    Widdicombe, J H; Widdicombe, J G

    1995-01-01

    Human airways are lined with a film of liquid from 5-100 microns in depth, consisting of a periciliary sol around and a mucous gel above the cilia. Microscopical studies have shown the sol to be invariably the same depth as the length of the cilia, and we discuss possible reasons for this. The composition and sources of the airway surface liquid are also described. In addition the forces regulating its volume are analyzed. Several airway diseases are characterised by dramatic changes in the volume and composition of airway liquid. We review recent research suggesting that the accumulation of airway mucous secretions in cystic fibrosis is caused by alterations in active transport of ions and water across both the surface and gland epithelia.

  8. Postnatal airway growth in cystic fibrosis piglets.

    PubMed

    Adam, Ryan J; Abou Alaiwa, Mahmoud H; Bouzek, Drake C; Cook, Daniel P; Gansemer, Nicholas D; Taft, Peter J; Powers, Linda S; Stroik, Mallory R; Hoegger, Mark J; McMenimen, James D; Hoffman, Eric A; Zabner, Joseph; Welsh, Michael J; Meyerholz, David K; Stoltz, David A

    2017-09-01

    Mutations in the gene encoding the cystic fibrosis (CF) transmembrane conductance regulator (CFTR) anion channel cause CF. The leading cause of death in the CF population is lung disease. Increasing evidence suggests that in utero airway development is CFTR-dependent and that developmental abnormalities may contribute to CF lung disease. However, relatively little is known about postnatal CF airway growth, largely because such studies are limited in humans. Therefore, we examined airway growth and lung volume in a porcine model of CF. We hypothesized that CF pigs would have abnormal postnatal airway growth. To test this hypothesis, we performed CT-based airway and lung volume measurements in 3-wk-old non-CF and CF pigs. We found that 3-wk-old CF pigs had tracheas of reduced caliber and irregular shape. Their bronchial lumens were reduced in size proximally but not distally, were irregularly shaped, and had reduced distensibility. Our data suggest that lack of CFTR results in aberrant postnatal airway growth and development, which could contribute to CF lung disease pathogenesis. NEW & NOTEWORTHY This CT scan-based study of airway morphometry in the cystic fibrosis (CF) postnatal period is unique, as analogous studies in humans are greatly limited for ethical and technical reasons. Findings such as reduced airway lumen area and irregular caliber suggest that airway growth and development are CF transmembrane conductance regulator-dependent and that airway growth defects may contribute to CF lung disease pathogenesis. Copyright © 2017 the American Physiological Society.

  9. A computational fluid dynamics simulation framework for ventricular catheter design optimization.

    PubMed

    Weisenberg, Sofy H; TerMaath, Stephanie C; Barbier, Charlotte N; Hill, Judith C; Killeffer, James A

    2017-11-10

    OBJECTIVE Cerebrospinal fluid (CSF) shunts are the primary treatment for patients suffering from hydrocephalus. While proven effective in symptom relief, these shunt systems are plagued by high failure rates and often require repeated revision surgeries to replace malfunctioning components. One of the leading causes of CSF shunt failure is obstruction of the ventricular catheter by aggregations of cells, proteins, blood clots, or fronds of choroid plexus that occlude the catheter's small inlet holes or even the full internal catheter lumen. Such obstructions can disrupt CSF diversion out of the ventricular system or impede it entirely. Previous studies have suggested that altering the catheter's fluid dynamics may help to reduce the likelihood of complete ventricular catheter failure caused by obstruction. However, systematic correlation between a ventricular catheter's design parameters and its performance, specifically its likelihood to become occluded, still remains unknown. Therefore, an automated, open-source computational fluid dynamics (CFD) simulation framework was developed for use in the medical community to determine optimized ventricular catheter designs and to rapidly explore parameter influence for a given flow objective. METHODS The computational framework was developed by coupling a 3D CFD solver and an iterative optimization algorithm and was implemented in a high-performance computing environment. The capabilities of the framework were demonstrated by computing an optimized ventricular catheter design that provides uniform flow rates through the catheter's inlet holes, a common design objective in the literature. The baseline computational model was validated using 3D nuclear imaging to provide flow velocities at the inlet holes and through the catheter. RESULTS The optimized catheter design achieved through use of the automated simulation framework improved significantly on previous attempts to reach a uniform inlet flow rate distribution using

  10. [Recording of ventricular pressure by conventional catheter manometer systems. Efficiency of several combinations of conventional catheters, modern transducers and catheter-flush systems (author's transl)].

    PubMed

    Hellige, G

    1976-01-01

    The experimentally in vitro determined dynamic response characteristics of 38 catheter manometer systems were uniform in the worst case to 5 c.p.s. and optimally to 26 c.p.s. Accordingly, some systems are only satisfactory for ordinary pressure recording in cardiac rest, while better systems record dp/dt correct up to moderate inotropic stimulation of the heart. In the frequency range of uniform response (amplitude error less +/- 5%) the phase distortion is also negligible. In clinical application the investigator is often restricted to special type of cardiac catheter. In this case a low compliant transducer yields superior results. In all examined systems the combination with MSD 10 transducers is best, whereas the combination with P 23 Db transducers leads to minimal results. An inadequate system for recording ventricular pressure pulses leads in most cases to overestimations of dp/dtmax. The use of low frequency pass filters to attenuate higher frequency artefacts is, under clinical conditions, not suitable for extending the range of uniform frequency response. The dynamic response of 14 catheter manometer systems with two types of continuous self flush units was determined. The use of the P 37 flush unit in combination with small internal diameter catheters leads to serious error in ordinary pressure recording, due to amplitude distortion of the lower harmonics. The frequency response characteristics of the combination of an Intraflow flush system and MSD 10 transducer was similar to the non-flushing P 23 Db transducer feature.

  11. Guidewire exchange vs new site placement for temporary dialysis catheter insertion in ICU patients: is there a greater risk of colonization or dysfunction?

    PubMed

    Coupez, Elisabeth; Timsit, Jean-François; Ruckly, Stéphane; Schwebel, Carole; Gruson, Didier; Canet, Emmanuel; Klouche, Kada; Argaud, Laurent; Bohe, Julien; Garrouste-Orgeas, Maïté; Mariat, Christophe; Vincent, François; Cayot, Sophie; Cointault, Olivier; Lepape, Alain; Darmon, Michael; Boyer, Alexandre; Azoulay, Elie; Bouadma, Lila; Lautrette, Alexandre; Souweine, Bertrand

    2016-07-30

    Intensive care unit (ICU) patients require dialysis catheters (DCs) for renal replacement therapy (RRT). They carry a high risk of developing end-stage renal disease, and therefore their vascular access must be preserved. Guidewire exchange (GWE) is often used to avoid venipuncture insertion (VPI) at a new site. However, the impact of GWE on infection and dysfunction of DCs in the ICU is unknown. Our aim was to compare the effect of GWE and VPI on DC colonization and dysfunction in ICU patients. Using data from the ELVIS randomized controlled trial (RCT) (1496 ICU adults requiring DC for RRT or plasma exchange) we performed a matched-cohort analysis. Cases were DCs inserted by GWE (n = 178). They were matched with DCs inserted by VPI. Matching criteria were participating centre, simplified acute physiology score (SAPS) II +/-10, insertion site (jugular or femoral), side for jugular site, and length of ICU stay before DC placement. We used a marginal Cox model to estimate the effect of DC insertion (GWE vs. VPI) on DC colonization and dysfunction. DC colonization rate was not different between GWE-DCs and VPI-DCs (10 (5.6 %) for both groups) but DC dysfunction was more frequent with GWE-DCs (67 (37.6 %) vs. 28 (15.7 %); hazard ratio (HR), 3.67 (2.07-6.49); p < 0.01). Results were similar if analysis was restricted to DCs changed for dysfunction. GWE for DCs in ICU patients, compared with VPI did not contribute to DC colonization or infection but was associated with more than twofold increase in DC dysfunction. This study is registered with ClinicalTrials.gov, number NCT00563342 . Registered 2 April 2009.

  12. 21 CFR 870.1240 - Flow-directed catheter.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Flow-directed catheter. 870.1240 Section 870.1240 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1240 Flow-directed catheter...

  13. 21 CFR 870.1370 - Catheter tip occluder.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Catheter tip occluder. 870.1370 Section 870.1370 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1370 Catheter tip occluder...

  14. 21 CFR 870.1370 - Catheter tip occluder.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Catheter tip occluder. 870.1370 Section 870.1370 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1370 Catheter tip occluder...

  15. 21 CFR 870.1240 - Flow-directed catheter.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Flow-directed catheter. 870.1240 Section 870.1240 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1240 Flow-directed catheter...

  16. Compatibility of electrolytically produced sodium hypochlorite solutions on long- term implanted dialysis catheters.

    PubMed

    Mishkin, G J

    2007-01-01

    More than 20% of the world's population use a catheter for dialysis, despite guidelines limiting their use. Although the structure and design of the catheters differ by manufacturer, the material used in central venous catheters and peritoneal dialysis catheters are the same across manufacturers. Given the long-term use of these catheters in the dialysis population, the good compatibility of the antiseptics and disinfectants used on the catheters is imperative to prevent failure and cracking of the catheter material. Tensile strengths of commercially available catheters were measured after exposure to commonly used disinfectants. The tensile strength was then compared between the catheters by analyzing the displacement vs. force (N) curves produced during the evaluation. A total of 44 catheter lumens were evaluated. The electrolytically produced sodium hypochlorite solution, Alcavis 50/ExSept Plus, was the only solution shown to be compatible with all three catheter materials resulting in a deviation of less than 10% for each of the different catheter types. Electrolytically produced sodium hypochlorite solutions were the only solutions in this study that did not alter the physical properties of any of the catheters after long-term exposure.

  17. Investigations of the pushability behavior of cardiovascular angiographic catheters.

    PubMed

    Bloss, Peter; Rothe, Wolfgang; Wünsche, Peter; Werner, Christian; Rothe, Alexander; Kneissl, Georg Dieter; Burger, Wolfram; Rehberg, Elisabeth

    2003-01-01

    The placement of angiographic catheters into the vascular system is a routine procedure in modern clinical business. The definition of objective but not yet available evaluation protocols based on measurable physical quantities correlated to the empirical clinical findings is of utmost importance for catheter manufacturers for in-house product screening and optimization. In this context, we present an assessment of multiple mechanical and surface catheter properties such as static and kinetic friction, bending stiffness, microscopic surface topology, surface roughness, surface free energy and their interrelation. Theoretical framework, description of experimental methods and extensive data measured on several different catheters are provided and in conclusion a testing procedure is defined. Although this procedure is based on the measurement of several physical quantities it can be easily implemented by commercial laboratories testing catheters as it is based on relatively low-cost standard methods.

  18. Comparison of air-charged and water-filled urodynamic pressure measurement catheters.

    PubMed

    Cooper, M A; Fletter, P C; Zaszczurynski, P J; Damaser, M S

    2011-03-01

    Catheter systems are utilized to measure pressure for diagnosis of voiding dysfunction. In a clinical setting, patient movement and urodynamic pumps introduce hydrostatic and motion artifacts into measurements. Therefore, complete characterization of a catheter system includes its response to artifacts as well its frequency response. The objective of this study was to compare the response of two disposable clinical catheter systems: water-filled and air-charged, to controlled pressure signals to assess their similarities and differences in pressure transduction. We characterized frequency response using a transient step test, which exposed the catheters to a sudden change in pressure; and a sinusoidal frequency sweep test, which exposed the catheters to a sinusoidal pressure wave from 1 to 30 Hz. The response of the catheters to motion artifacts was tested using a vortex and the response to hydrostatic pressure changes was tested by moving the catheter tips to calibrated heights. Water-filled catheters acted as an underdamped system, resonating at 10.13 ± 1.03 Hz and attenuating signals at frequencies higher than 19 Hz. They demonstrated significant motion and hydrostatic artifacts. Air-charged catheters acted as an overdamped system and attenuated signals at frequencies higher than 3.02 ± 0.13 Hz. They demonstrated significantly less motion and hydrostatic artifacts than water-filled catheters. The transient step and frequency sweep tests gave comparable results. Air-charged and water-filled catheters respond to pressure changes in dramatically different ways. Knowledge of the characteristics of the pressure-measuring system is essential to finding the best match for a specific application. Copyright © 2011 Wiley-Liss, Inc.

  19. Radiological Tenckhoff catheter insertion for peritoneal dialysis: A cost-effective approach.

    PubMed

    Lee, James; Mott, Nigel; Mahmood, Usman; Clouston, John; Summers, Kara; Nicholas, Pauline; Gois, Pedro Henrique França; Ranganathan, Dwarakanathan

    2018-04-01

    Radiological insertion of Tenckhoff catheters can be an alternative option for peritoneal dialysis access creation, as compared to surgical catheter insertion. This study will review the outcomes and complications of radiological Tenckhoff catheter insertion in a metropolitan renal service and compare costs between surgical and radiological insertion. Data were collected prospectively for all patients who had a Tenckhoff catheter insertion for peritoneal dialysis (PD) under radiological guidance at our hospital from May 2014 to November 2016. The type of catheter used and complications, including peri-catheter leak, exit site infection and peritonitis were reviewed. Follow-up data were also collected at points 3, 6 and 12 months from catheter insertion. Costing data were obtained from Queensland Health Electronic Reporting System (QHERS) data, average staff salaries and consumable contract price lists. In the 30-month evaluation period, 70 catheters were inserted. Two patients had an unsuccessful procedure due to the presence of abdominal adhesions. Seven patients had an episode of peri-catheter leak, and four patients had an exit site infection following catheter insertion. Peritonitis was observed in nine patients during the study period. The majority of patients (90%) remained on peritoneal dialysis at 3-month follow-up. The average costs of surgical and radiological insertion were noted to be AUD$7788.34 and AUD$1597.35, respectively. Radiological Tenckhoff catheter insertion for peritoneal dialysis appears to be an attractive and cost-effective option given less waiting periods for the procedure, the relatively low cost of insertion and comparable rates of complications. © 2017 The Royal Australian and New Zealand College of Radiologists.

  20. Catheter-associated urinary tract infections and other infections in patients hospitalized for acute stroke: A prospective cohort study of two different silicone catheters.

    PubMed

    Stenzelius, Karin; Laszlo, Liselott; Madeja, Magdalena; Pessah-Rasmusson, Hélène; Grabe, Magnus

    2016-12-01

    Catheter-associated urinary tract infection (CAUTI) is the most common healthcare-associated infection. The primary aim of this study was to investigate whether the use of a silicone catheter coated with an ultrathin layer of a combination of the noble metals gold, palladium and silver (BIP™-silicone catheter) could reduce the incidence of CAUTI and antibiotic prescription compared with a standard silicone catheter in a cohort of acute neurological patients suffering primarily from stroke. At the same time, all infectious events requiring prescription of an antimicrobial agent were registered and are reported. The study was designed as a crossover cohort study enrolling men and women aged over 18 years, requiring emergency management for stroke including the insertion of an indwelling catheter. Data on patient characteristics, urinary tract infections (UTIs), other infectious events and all antibiotic prescriptions were recorded prospectively. The patients' characteristics differed in the two centres in terms of age but not in diagnosis distribution. UTIs were recorded in 78 (24.2%) of the patients, ahead of pulmonary tract infections (n = 65; 20.2%). There was no difference in terms of CAUTI in the two catheter groups, even in subgroups with catheter treatment for 1 week or less. The patients with a diagnosed UTI required 3.5 more days of hospitalization than those without a UTI. CAUTIs were the most frequent healthcare-associated infections, slightly ahead of pulmonary tract infections. No advantages of the coated catheter could be found in this cohort of critically ill patients.

  1. Reducing unnecessary urinary catheter use and other strategies to prevent catheter-associated urinary tract infection: an integrative review

    PubMed Central

    Meddings, Jennifer; Rogers, Mary A M; Krein, Sarah L; Fakih, Mohamad G; Olmsted, Russell N; Saint, Sanjay

    2014-01-01

    Background Catheter-associated urinary tract infections (CAUTI) are costly, common and often preventable by reducing unnecessary urinary catheter (UC) use. Methods To summarise interventions to reduce UC use and CAUTIs, we updated a prior systematic review (through October 2012), and a meta-analysis regarding interventions prompting UC removal by reminders or stop orders. A narrative review summarises other CAUTI prevention strategies including aseptic insertion, catheter maintenance, antimicrobial UCs, and bladder bundle implementation. Results 30 studies were identified and summarised with interventions to prompt removal of UCs, with potential for inclusion in the meta-analyses. By meta-analysis (11 studies), the rate of CAUTI (episodes per 1000 catheter-days) was reduced by 53% (rate ratio 0.47; 95% CI 0.30 to 0.64, p<0.001) using a reminder or stop order, with five studies also including interventions to decrease initial UC placement. The pooled (nine studies) standardised mean difference (SMD) in catheterisation duration (days) was −1.06 overall (p=0.065) including a statistically significant decrease in stop-order studies (SMD −0.37; p<0.001) but not in reminder studies (SMD, −1.54; p=0.071). No significant harm from catheter removal strategies is supported. Limited research is available regarding the impact of UC insertion and maintenance technique. A recent randomised controlled trial indicates antimicrobial catheters provide no significant benefit in preventing symptomatic CAUTIs. Conclusions UC reminders and stop orders appear to reduce CAUTI rates and should be used to improve patient safety. Several evidence-based guidelines have evaluated CAUTI preventive strategies as well as emerging evidence regarding intervention bundles. Implementation strategies are important because reducing UC use involves changing well-established habits. PMID:24077850

  2. Intrathoracic airway measurement: ex-vivo validation

    NASA Astrophysics Data System (ADS)

    Reinhardt, Joseph M.; Raab, Stephen A.; D'Souza, Neil D.; Hoffman, Eric A.

    1997-05-01

    High-resolution x-ray CT (HRCT) provides detailed images of the lungs and bronchial tree. HRCT-based imaging and quantitation of peripheral bronchial airway geometry provides a valuable tool for assessing regional airway physiology. Such measurements have been sued to address physiological questions related to the mechanics of airway collapse in sleep apnea, the measurement of airway response to broncho-constriction agents, and to evaluate and track the progression of disease affecting the airways, such as asthma and cystic fibrosis. Significant attention has been paid to the measurements of extra- and intra-thoracic airways in 2D sections from volumetric x-ray CT. A variety of manual and semi-automatic techniques have been proposed for airway geometry measurement, including the use of standardized display window and level settings for caliper measurements, methods based on manual or semi-automatic border tracing, and more objective, quantitative approaches such as the use of the 'half-max' criteria. A recently proposed measurements technique uses a model-based deconvolution to estimate the location of the inner and outer airway walls. Validation using a plexiglass phantom indicates that the model-based method is more accurate than the half-max approach for thin-walled structures. In vivo validation of these airway measurement techniques is difficult because of the problems in identifying a reliable measurement 'gold standard.' In this paper we report on ex vivo validation of the half-max and model-based methods using an excised pig lung. The lung is sliced into thin sections of tissue and scanned using an electron beam CT scanner. Airways of interest are measured from the CT images, and also measured with using a microscope and micrometer to obtain a measurement gold standard. The result show no significant difference between the model-based measurements and the gold standard; while the half-max estimates exhibited a measurement bias and were significantly

  3. The Development and Application of Airway Devices in China

    PubMed Central

    Chen, Xiangdong; Ma, Wuhua; Liu, Renyu; Yao, Shanglong

    2017-01-01

    Airway management is one of the most important tasks for anesthesiologists. Anesthesiologists are experts in airway management and have made tremendous contribution to the development of the airway devices. Chinese anesthesiologists have made significant contribution in introducing advanced airway management and developing innovative techniques and devices for airway management in China. This article overviews the development and application of airway devices in China as well as the dedication and contribution of Chinese experts in the development of novel airway devices. With the development of science and technology accompanied by the advanced knowledge in airway management, more effective and safe artificial airways will be developed for clinical practice. The authors believe that Chinese experts will continue their outstanding contribution to the development of innovative airway devices, systems and knowledge. PMID:28191485

  4. Risk factor analysis for long-term tunneled dialysis catheter-related bacteremias.

    PubMed

    Jean, G; Charra, B; Chazot, C; Vanel, T; Terrat, J C; Hurot, J M; Laurent, G

    2002-07-01

    Infection, mainly related to vascular access, is one of the main causes of morbidity and a preventable cause of death in hemodialysis patients. From January 1994 to April 1998 we conducted a prospective study to assess the incidence and risk factors of catheter-related bacteremia. One hundred and twenty-nine tunneled dual-lumen hemodialysis catheters were inserted percutaneously into the internal jugular vein in 89 patients. Bacteremia (n = 56) occurred at least once with 37 (29%) of the catheters (an incidence of 1.1/1,000 catheter-days); local infection (n = 45, 1/1,000 catheter-days) was associated with bacteremia in 18 cases. Death in 1 case was directly related to Staphylococcus aureus (SA) septic shock, and septicemia contributed to deaths in 2 additional cases. Catheters were removed in 48% of the bacteremic episodes. Treatment comprised intravenous double antimicrobial therapy for 15-20 days. Bacteriological data of bacteremia showed 55% involvement of SA. Nasal carriage of SA was observed in 35% of the patients with catheters. Bacteremic catheters were more frequently observed in patients with diabetes mellitus (p = 0.03), peripheral atherosclerosis (p = 0.001), a previous history of bacteremia (p = 0.05), nasal carriage of SA (p = 0.0001), longer catheter survival time (p = 0.001), higher total intravenous iron dose (p = 0.001), more frequent urokinase catheter infusion (p < 0.01), and local infection (p < 0.001) compared with non-bacteremic catheters. Monovariate survival analysis showed that significant initial risk factors for bacteremia were nasal carriage of SA (p = 0.00001), previous bacteremia (p = 0.0001), peripheral atherosclerosis (p = 0.005), and diabetes (p = 0.04). This study confirms the relatively high incidence of bacteremia with tunneled double-lumen silicone catheters and its potential complications. Possible preventive actions are discussed according to the risk factors. Copyright 2002 S. Karger AG, Basel

  5. Airway smooth muscle responsiveness from dogs with airway hyperresponsiveness after O/sub 3/ inhalation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jones, G.L.; O'Byrne, P.M.; Pashley, M.

    1988-07-01

    Airway hyperresponsiveness occurs after inhalation of O3 in dogs. The purpose of this study was to examine the responsiveness of trachealis smooth muscle in vitro to electrical field stimulation, exogenous acetylcholine, and potassium chloride from dogs with airway hyperresponsiveness after inhaled O3 in vivo and to compare this with the responsiveness of trachealis muscle from control dogs. In addition, excitatory junction potentials were measured with the use of single and double sucrose gap techniques in both groups of dogs to determine whether inhaled O3 affects the release of acetylcholine from parasympathetic nerves in trachealis muscle. Airway hyperresponsiveness developed in allmore » dogs after inhaled O3 (3 ppm for 30 min). The acetylcholine provocative concentration decreased from 4.11 mg/ml before O3 inhalation to 0.66 mg/ml after O3 (P less than 0.0001). The acetylcholine provocative concentration increased slightly after control inhalation of dry room air. Airway smooth muscle showed increased responses to both electrical field stimulation and exogenous acetylcholine but not to potassium chloride in preparations from dogs with airway hyperresponsiveness in vivo. The increased response to electrical field stimulation was not associated with a change in excitatory junctional potentials. These results suggest that a postjunctional alteration in trachealis muscle function occurs after inhaled O3 in dogs, which may account for airway hyperresponsiveness after O3 in vivo.« less

  6. Cryo-balloon catheter position planning using AFiT

    NASA Astrophysics Data System (ADS)

    Kleinoeder, Andreas; Brost, Alexander; Bourier, Felix; Koch, Martin; Kurzidim, Klaus; Hornegger, Joachim; Strobel, Norbert

    2012-02-01

    Atrial fibrillation (AFib) is the most common heart arrhythmia. In certain situations, it can result in life-threatening complications such as stroke and heart failure. For paroxsysmal AFib, pulmonary vein isolation (PVI) by catheter ablation is the recommended choice of treatment if drug therapy fails. During minimally invasive procedures, electrically active tissue around the pulmonary veins is destroyed by either applying heat or cryothermal energy to the tissue. The procedure is usually performed in electrophysiology labs under fluoroscopic guidance. Besides radio-frequency catheter ablation devices, so-called single-shot devices, e.g., the cryothermal balloon catheters, are receiving more and more interest in the electrophysiology (EP) community. Single-shot devices may be advantageous for certain cases, since they can simplify the creation of contiguous (gapless) lesion sets around the pulmonary vein which is needed to achieve PVI. In many cases, a 3-D (CT, MRI, or C-arm CT) image of a patient's left atrium is available. This data can then be used for planning purposes and for supporting catheter navigation during the procedure. Cryo-thermal balloon catheters are commercially available in two different sizes. We propose the Atrial Fibrillation Planning Tool (AFiT), which visualizes the segmented left atrium as well as multiple cryo-balloon catheters within a virtual reality, to find out how well cryo-balloons fit to the anatomy of a patient's left atrium. First evaluations have shown that AFiT helps physicians in two ways. First, they can better assess whether cryoballoon ablation or RF ablation is the treatment of choice at all. Second, they can select the proper-size cryo-balloon catheter with more confidence.

  7. Heuristic estimation of electromagnetically tracked catheter shape for image-guided vascular procedures

    NASA Astrophysics Data System (ADS)

    Mefleh, Fuad N.; Baker, G. Hamilton; Kwartowitz, David M.

    2014-03-01

    In our previous work we presented a novel image-guided surgery (IGS) system, Kit for Navigation by Image Focused Exploration (KNIFE).1,2 KNIFE has been demonstrated to be effective in guiding mock clinical procedures with the tip of an electromagnetically tracked catheter overlaid onto a pre-captured bi-plane fluoroscopic loop. Representation of the catheter in KNIFE differs greatly from what is captured by the fluoroscope, due to distortions and other properties of fluoroscopic images. When imaged by a fluoroscope, catheters can be visualized due to the inclusion of radiopaque materials (i.e. Bi, Ba, W) in the polymer blend.3 However, in KNIFE catheter location is determined using a single tracking seed located in the catheter tip that is represented as a single point overlaid on pre-captured fluoroscopic images. To bridge the gap in catheter representation between KNIFE and traditional methods we constructed a catheter with five tracking seeds positioned along the distal 70 mm of the catheter. We have currently investigated the use of four spline interpolation methods for estimation of true catheter shape and have assesed the error in their estimation of true catheter shape. In this work we present a method for the evaluation of interpolation algorithms with respect to catheter shape determination.

  8. Alcohol and Airways Function in Health and Disease

    PubMed Central

    Sisson, Joseph H.

    2007-01-01

    The volatility of alcohol promotes the movement of alcohol from the bronchial circulation across the airway epithelium and into the conducting airways of the lung. The exposure of the airways through this route likely accounts for many of the biologic effects of alcohol on lung airway functions. The impact of alcohol on lung airway functions is dependent on the concentration, duration and route of exposure. Brief exposure to mild concentrations of alcohol may enhance mucociliary clearance, stimulates bronchodilation and probably attenuates the airway inflammation and injury observed in asthma and COPD. Prolonged and heavy exposure to alcohol impairs mucociliary clearance, may complicate asthma management and likely worsens outcomes including lung function and mortality in COPD patients. Non-alcohol congeners and alcohol metabolites act as triggers for airway disease exacerbations especially in atopic asthmatics and in Asian populations who have a reduced capacity to metabolize alcohol. Research focused on the mechanisms of alcohol-mediated changes in airway functions has identified specific mechanisms that mediate alcohol effects within the lung airways. These include prominent roles for the second messengers calcium and nitric oxide, regulatory kinases including PKG and PKA, alcohol and acetaldehyde-metabolizing enzymes such as aldehyde dehydrogenase type 2 (ALDH2). The role alcohol may play in the pathobiology of airway mucus, bronchial blood flow, airway smooth muscle regulation and the interaction with other airway exposure agents, such as cigarette smoke, represent opportunities for future investigation. PMID:17764883

  9. Alcohol and airways function in health and disease.

    PubMed

    Sisson, Joseph H

    2007-08-01

    The volatility of alcohol promotes the movement of alcohol from the bronchial circulation across the airway epithelium and into the conducting airways of the lung. The exposure of the airways through this route likely accounts for many of the biologic effects of alcohol on lung airway functions. The effect of alcohol on lung airway functions is dependent on the concentration, duration, and route of exposure. Brief exposure to mild concentrations of alcohol may enhance mucociliary clearance, stimulates bronchodilation, and probably attenuates the airway inflammation and injury observed in asthma and chronic obstructive pulmonary disease (COPD). Prolonged and heavy exposure to alcohol impairs mucociliary clearance, may complicate asthma management, and likely worsens outcomes including lung function and mortality in COPD patients. Nonalcohol congeners and alcohol metabolites act as triggers for airway disease exacerbations especially in atopic asthmatics and in Asian populations who have a reduced capacity to metabolize alcohol. Research focused on the mechanisms of alcohol-mediated changes in airway functions has identified specific mechanisms that mediate alcohol effects within the lung airways. These include prominent roles for the second messengers calcium and nitric oxide, regulatory kinases including PKG and PKA, alcohol- and acetaldehyde-metabolizing enzymes such as aldehyde dehydrogenase 2. The role alcohol may play in the pathobiology of airway mucus, bronchial blood flow, airway smooth muscle regulation, and the interaction with other airway exposure agents, such as cigarette smoke, represents opportunities for future investigation.

  10. A prospective randomized trial comparing Foley catheter, oxytocin, and combination Foley catheter-oxytocin for labour induction with unfavourable cervix.

    PubMed

    El Khouly, Nabih I

    2017-04-01

    The purpose of this study was to evaluate the effectiveness and safety of transcervical Foley catheter with and without oxytocin versus oxytocin alone for labour induction with unfavourable cervix. This trial enrolled 108 women with singleton pregnancies presented for labour induction with unfavourable cervix. Patients were randomly assigned to receive Foley catheter alone (I), Foley catheter plus oxytocin (II) or oxytocin alone (III). Outcomes were analysed in terms of success of induction, induction delivery interval, route of delivery, dose and duration of oxytocin, and complications. Successful normal vaginal delivery was more common in group I (p = .02) compared to group III. Induction delivery time was statistically shorter in group II and group III (p < .001). Patients in group I required significantly less oxytocin dose and duration (p < .001). This led to our conclusion that induction of labour with Foley catheter without oxytocin increases success rate of normal vaginal delivery; however, it has a longer induction delivery interval with similar complications.

  11. Adverse effects associated with ethanol catheter lock solutions: a systematic review.

    PubMed

    Mermel, Leonard A; Alang, Neha

    2014-10-01

    Antimicrobial lock therapy has been widely utilized internationally for the prevention and management of intravascular catheter-related bloodstream infections. One of the agents commonly utilized for lock therapy is ethanol. However, a systematic review of adverse events associated with ethanol locks has not been published. PubMed was searched to collect articles published from May 2003 through March 2014. The bibliographies of relevant articles were also reviewed. In vitro studies of the mechanical properties of catheters after ethanol immersion have revealed changes predominantly in polyurethane catheters and to a lesser extent in silicone and Carbothane catheters. An elution of polymers from polyurethane and Carbothane catheters has been observed at the ethanol concentrations used in ethanol lock therapy. Ethanol above a concentration of 28% leads to plasma protein precipitation. Ethanol locks were associated with catheter occlusion in 11 studies and independently increased the risk of thrombosis compared with heparin lock in a randomized trial. Six studies noted abnormalities in catheter integrity, including one case leading to catheter embolization. Of note, five of these studies involved silicone catheters. Ethanol lock use was associated with systemic side effects in 10 studies and possible side effects in one additional study. Four studies noted liver function test abnormalities, predominantly transaminase elevation, related to ethanol lock use. However, a prospective study did not find any difference in the risk of doubling the transaminase level above the normal range during use of ethanol locks compared with not using an ethanol lock. The use of ethanol locks has been associated with structural changes in catheters, as well as the elution of molecules from the catheter polymers. Clinical studies have revealed systemic toxicity, increased catheter occlusion and breaches in catheter integrity. © The Author 2014. Published by Oxford University Press on

  12. High definition urethral pressure profilometry: Evaluating a novel microtip catheter.

    PubMed

    Klünder, Mario; Amend, Bastian; Vaegler, Martin; Kelp, Alexandra; Feuer, Ronny; Sievert, Karl-Dietrich; Stenzl, Arnulf; Sawodny, Oliver; Ederer, Michael

    2016-11-01

    Urethral pressure profilometry (UPP) is used in the diagnosis of stress urinary incontinence (SUI). SUI is a significant medical, social, and economic problem, affecting about 12.5% of the population. A novel microtip catheter was developed for UPP featuring an inclination sensor and higher angular resolution compared to systems in clinical use today. Therewith, the location of each measured pressure sample can be determined and the spatial pressure distribution inside the urethra reconstructed. In order to assess the performance and plausibility of data from the microtip catheter, we compare it to data from a double balloon air charged system. Both catheters are used on sedated female minipigs. Data from the microtip catheter are processed through a signal reconstruction algorithm, plotted and compared against data from the air-charged catheter. The microtip catheter delivers results in agreement with previous comparisons of microtip and air-charged systems. It additionally provides a new level of detail in the reconstructed UPPs which may lead to new insights into the sphincter mechanism of minipigs. The ability of air-charged catheters to measure pressure circumferentially is widely considered a main advantage over microtip catheters. However, directional pressure readings can provide additional information on angular fluctuations in the urethral pressure distribution. It is shown that the novel microtip catheter in combination with a signal reconstruction algorithm delivers plausible data. It offers the opportunity to evaluate urethral structures, especially the sphincter, in context of the correct location within the anatomical location of the pelvic floor. Neurourol. Urodynam. 35:888-894, 2016. © 2015 Wiley Periodicals, Inc. © 2015 Wiley Periodicals, Inc.

  13. The effect of elastic modulus on ablation catheter contact area.

    PubMed

    Camp, Jon J; Linte, Cristian A; Rettmann, Maryam E; Sun, Deyu; Packer, Douglas L; Robb, Richard A; Holmes, David R

    2015-02-21

    Cardiac ablation consists of navigating a catheter into the heart and delivering RF energy to electrically isolate tissue regions that generate or propagate arrhythmia. Besides the challenges of accurate and precise targeting of the arrhythmic sites within the beating heart, limited information is currently available to the cardiologist regarding intricate electrode-tissue contact, which directly impacts the quality of produced lesions. Recent advances in ablation catheter design provide intra-procedural estimates of tissue-catheter contact force, but the most direct indicator of lesion quality for any particular energy level and duration is the tissue-catheter contact area, and that is a function of not only force, but catheter pose and material elasticity as well. In this experiment, we have employed real-time ultrasound (US) imaging to determine the complete interaction between the ablation electrode and tissue to accurately estimate contact, which will help to better understand the effect of catheter pose and position relative to the tissue. By simultaneously recording tracked position, force reading and US image of the ablation catheter, the differing material properties of polyvinyl alcohol cryogel [1] phantoms are shown to produce varying amounts of tissue depression and contact area (implying varying lesion quality) for equivalent force readings. We have shown that the elastic modulus significantly affects the surface-contact area between the catheter and tissue at any level of contact force. Thus we provide evidence that a prescribed level of catheter force may not always provide sufficient contact area to produce an effective ablation lesion in the prescribed ablation time.

  14. Long-Term Outcomes of Single-Port Laparoscopic Placement of Peritoneal Dialysis Catheter.

    PubMed

    Pan, Alan; Poi, Mun J; Matos, Jesus; Jiang, Jenny S; Kfoury, Elias; Echeverria, Angela; Bechara, Carlos F; Lin, Peter H

    2016-07-01

    Laparoscopic insertion of peritoneal dialysis (PD) catheter has become a preferred method compared to the traditional open technique for PD catheter insertion. We retrospectively report the outcome of 1-port laparoscopic placement PD catheters in our institution. A total of 263 patients with end-stage renal disease who underwent single-trocar laparoscopic PD catheter insertion during a recent 6-year period were reviewed. Laparoscopic technique involves introducing a PD catheter over a stiff guidewire into the abdominal cavity through a 10-mm laparoscopic port. Pertinent clinical variables, procedural complications, and follow-up outcome were analyzed. There were 182 men and 81 women. The mean age was 56 years. Technical success was 95.8%. Catheter occlusion was the most common early complications (<6 months) that occurred in 4 (1.5%) patients. Late complications (> 6 months) including catheter occlusion, cuff extrusion, catheter leakage, catheter migration, infection, and hernia occurred in 5 patients (1.9%), 2 patients (0.8%), 3 patients (1.1%), 3 patients (1.1%), 6 patients (2.3%), and 4 patients (1.5), respectively. Mean follow-up time was 39 ± 18 months. Catheter survival rate at 1, 2, 3, 4, and 5 years was 96%, 94%, 90%, 85%, and 82%, respectively. Laparoscopic PD catheter implantation via a single-trocar utilizing a stiff guidewire technique is feasible and safe. This method can result in low complication and high catheter survival rate. © The Author(s) 2016.

  15. Modified laparoscopic placement of peritoneal dialysis catheter with intra-abdominal fixation.

    PubMed

    Shen, Quanquan; Jiang, Xinxin; Shen, Xiaogang; Yu, Fangyan; Tu, Qiudi; Chen, Wangfang; Ye, Qing; Behera, Tapas Ranjan; He, Qiang

    2017-08-01

    Peritoneal dialysis (PD) is a commonly accepted method of treating end-stage renal disease (ESRD). Various laparoscopic techniques for the placement of PD catheter have been described. In this study, we developed a novel modified laparoscopic technique for PD catheter placement and evaluated the early results. A straight Tenckhoff PD catheter was placed employing the modified technique in 39 consecutive patients with ESRD from May 2013 to April 2016. The technique is laparoscopically guided intra-abdominal fixation of the PD catheter tip at one point by using suture passer hernia forceps. Individual information including sex, age, primary disease etiology, complications, surgical duration, morbidity, mortality and catheter survival was collected and analyzed. The modified laparoscopic procedure was effectively performed in all patients with a mean operative time of 45 ± 7 min. No conversions from laparoscopy to open surgery of catheter placement occurred. There was one case showing early pericatheter leakage. There were no serious complications, such as bleeding, abdominal wall hernias, distal catheter cuff extrusion and infections of the exit site or tunnel during surgery or the postoperative duration. No mortality was observed in this group of patients. The 6-month follow-up study showed 100% catheter-related complication-free survival. Our modified laparoscopic intra-abdominal fixation technique using suture passer hernia forceps is a simple and safe method for PD catheter placement and is effective in minimizing the risk of catheter migration.

  16. Elevated Airway Purines in COPD

    PubMed Central

    Lazaar, Aili L.; Bordonali, Elena; Qaqish, Bahjat; Boucher, Richard C.

    2011-01-01

    Background: Adenosine and related purines have established roles in inflammation, and elevated airway concentrations are predicted in patients with COPD. However, accurate airway surface purine measurements can be confounded by stimulation of purine release during collection of typical respiratory samples. Methods: Airway samples were collected noninvasively as exhaled breath condensate (EBC) from 36 healthy nonsmokers (NS group), 28 healthy smokers (S group), and 89 subjects with COPD (29 with GOLD [Global Initiative for Chronic Obstructive Lung Disease] stage II, 29 with GOLD stage III, and 31 with GOLD stage IV) and analyzed with mass spectrometry for adenosine, adenosine monophosphate (AMP), and phenylalanine, plus urea as a dilution marker. Variable dilution of airway secretions in EBC was controlled using ratios to urea, and airway surface concentrations were calculated using EBC to serum urea-based dilution factors. Results: EBC adenosine to urea ratios were similar in NS (0.20 ± 0.21) and S (0.22 ± 0.20) groups but elevated in those with COPD (0.32 ± 0.30, P < .01 vs NS). Adenosine to urea ratios were highest in the most severely affected cohort (GOLD IV, 0.35 ± 0.34, P < .01 vs NS) and negatively correlated with FEV1 (r = −0.27, P < .01). Elevated AMP to urea ratios were also observed in the COPD group (0.58 ± 0.97 COPD, 0.29 ± 0.35 NS, P < .02), but phenylalanine to urea ratios were similar in all groups. Airway surface adenosine concentrations calculated in a subset of subjects were 3.2 ± 2.7 μM in those with COPD (n = 28) relative to 1.7 ± 1.5 μM in the NS group (n = 16, P < .05). Conclusions: Airway purines are present on airway surfaces at physiologically significant concentrations, are elevated in COPD, and correlate with markers of COPD severity. Purinergic signaling pathways are potential therapeutic targets in COPD, and EBC purines are potential noninvasive biomarkers. PMID:21454402

  17. [Disposable nursing applicator-pocket of indwelling central venous catheter].

    PubMed

    Wei, Congli; Ma, Chunyuan

    2017-11-01

    Catheter related infection is the most common complication of central venous catheter, which pathogen mainly originate from the pipe joint and the skin around puncture site. How to prevent catheter infection is an important issue in clinical nursing. The utility model disclosed a "disposable nursing applicator-pocket of indwelling central venous catheter", which is mainly used for the fixation and the protection. The main structure consists of two parts, one is medical applicator to protect the skin around puncture site, and the other is gauze pocket to protect the catheter external connector. When in use, the catheter connector is fitted into the pocket, and then the applicator is applied to cover the puncture point of the skin. Integrated design of medical applicator and gauze pocket was designed to realize double functions of fixation and protection. The disposable nursing applicator-pocket is made of medical absorbent gauze (outer layer) and non-woven fabric (inner layer), which has the characteristics of comfortable, breathable, dust filtered, bacteria filtered, waterproof, antiperspirant and anti-pollution. The utility model has the advantages of simple structure, low cost, simple operation, effective protection, easy realization and popularization.

  18. Anatomic and physiopathologic changes affecting the airway of the elderly patient: implications for geriatric-focused airway management

    PubMed Central

    Johnson, Kathleen N; Botros, Daniel B; Groban, Leanne; Bryan, Yvon F

    2015-01-01

    There are many anatomical, physiopathological, and cognitive changes that occur in the elderly that affect different components of airway management: intubation, ventilation, oxygenation, and risk of aspiration. Anatomical changes occur in different areas of the airway from the oral cavity to the larynx. Common changes to the airway include tooth decay, oropharyngeal tumors, and significant decreases in neck range of motion. These changes may make intubation challenging by making it difficult to visualize the vocal cords and/or place the endotracheal tube. Also, some of these changes, including but not limited to, atrophy of the muscles around the lips and an edentulous mouth, affect bag mask ventilation due to a difficult face-mask seal. Physiopathologic changes may impact airway management as well. Common pulmonary issues in the elderly (eg, obstructive sleep apnea and COPD) increase the risk of an oxygen desaturation event, while gastrointestinal issues (eg, achalasia and gastroesophageal reflux disease) increase the risk of aspiration. Finally, cognitive changes (eg, dementia) not often seen as related to airway management may affect patient cooperation, especially if an awake intubation is required. Overall, degradation of the airway along with other physiopathologic and cognitive changes makes the elderly population more prone to complications related to airway management. When deciding which airway devices and techniques to use for intubation, the clinician should also consider the difficulty associated with ventilating the patient, the patient’s risk of oxygen desaturation, and/or aspiration. For patients who may be difficult to bag mask ventilate or who have a risk of aspiration, a specialized supralaryngeal device may be preferable over bag mask for ventilation. Patients with tumors or decreased neck range of motion may require a device with more finesse and maneuverability, such as a flexible fiberoptic broncho-scope. Overall, geriatric-focused airway

  19. The Difficult Airway Society 'ADEPT' guidance on selecting airway devices: the basis of a strategy for equipment evaluation.

    PubMed

    Pandit, J J; Popat, M T; Cook, T M; Wilkes, A R; Groom, P; Cooke, H; Kapila, A; O'Sullivan, E

    2011-08-01

    Faced with the concern that an increasing number of airway management devices were being introduced into clinical practice with little or no prior evidence of their clinical efficacy or safety, the Difficult Airway Society formed a working party (Airway Device Evaluation Project Team) to establish a process by which the airway management community within the profession could itself lead a process of formal device/equipment evaluation. Although there are several national and international regulations governing which products can come on to the market and be legitimately sold, there has hitherto been no formal professional guidance relating to how products should be selected (i.e. purchased). The Airway Device Evaluation Project Team's first task was to formulate such advice, emphasising evidence-based principles. Team discussions led to a definition of the minimum level of evidence needed to make a pragmatic decision about the purchase or selection of an airway device. The Team concluded that this definition should form the basis of a professional standard, guiding those with responsibility for selecting airway devices. We describe how widespread adoption of this professional standard can act as a driver to create an infrastructure in which the required evidence can be obtained. Essential elements are that: (i) the Difficult Airway Society facilitates a coherent national network of research-active units; and (ii) individual anaesthetists in hospital trusts play a more active role in local purchasing decisions, applying the relevant evidence and communicating their purchasing decisions to the Difficult Airway Society. © 2011 The Authors. Anaesthesia © 2011 The Association of Anaesthetists of Great Britain and Ireland.

  20. Multi-stage surgery for airway patency after metallic stent removal in benign laryngotracheal airway disease in two adolescents.

    PubMed

    Coordes, Annekatrin; Todt, Ingo; Ernst, Arne; Seidl, Rainer O

    2013-05-01

    Laryngotracheal stents may damage the highly complex laryngeal structures, impair voice and swallowing functions and cause tissue ingrowths, thereby necessitating airway patency interventions. In benign airway disease, the number of adolescents with laryngotracheal stents is therefore limited. We present two cases of laryngeal metallic stent placement following benign airway disease. Two adolescents presented with severe dyspnea and self-expandable metallic stent placement after benign laryngotracheal stenoses. Granulation tissue ingrowths required additional surgical interventions every 6-8 weeks to recanalize the stent lumen. We performed multi-stage surgery including removal of the embedded stent, segmental resection of the stenotic area, end-to-end-anastomosis and laryngotracheal reconstruction respectively, to achieve patent airway without tracheal cannulation. Montgomery T-tubes were temporarily inserted to bridge the complex reconstructions. In both adolescents, we achieved successful removal of the embedded stent and patent airway. Bilateral vocal fold paralysis required additional surgery to improve the final airway patency and vocal rehabilitation. Stent removal, segmental resection and laryngotracheal reconstruction provide the achievement of patent airway and allow decannulation. Temporary Montgomery T-tubes bridge complex laryngotracheal reconstructions. In benign laryngeal airway disease, stent placement should be avoided, especially in adolescents. Transfer to a specialist center should be considered prior to metallic stent implantation. In general, self-expanding tracheobronchial stents can be placed in selected patients where surgical interventions are limited. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  1. A novel four-wire-driven robotic catheter for radio-frequency ablation treatment.

    PubMed

    Yoshimitsu, Kitaro; Kato, Takahisa; Song, Sang-Eun; Hata, Nobuhiko

    2014-09-01

       Robotic catheters have been proposed to increase the efficacy and safety of the radio-frequency ablation treatment. The robotized motion of current robotic catheters mimics the motion of manual ones-namely, deflection in one direction and rotation around the catheter. With the expectation that the higher dexterity may achieve further efficacy and safety of the robotically driven treatment, we prototyped a four-wire-driven robotic catheter with the ability to deflect in two- degree-of-freedom motions in addition to rotation.    A novel quad-directional structure with two wires was designed and developed to attain yaw and pitch motion in the robotic catheter. We performed a mechanical evaluation of the bendability and maneuverability of the robotic catheter and compared it with current manual catheters.    We found that the four-wire-driven robotic catheter can achieve a pitching angle of 184.7[Formula: see text] at a pulling distance of wire for 11 mm, while the yawing angle was 170.4[Formula: see text] at 11 mm. The robotic catheter could attain the simultaneous two- degree-of-freedom motions in a simulated cardiac chamber.    The results indicate that the four-wire-driven robotic catheter may offer physicians the opportunity to intuitively control a catheter and smoothly approach the focus position that they aim to ablate.

  2. Integrated care pathways for airway diseases (AIRWAYS-ICPs).

    PubMed

    Bousquet, J; Addis, A; Adcock, I; Agache, I; Agusti, A; Alonso, A; Annesi-Maesano, I; Anto, J M; Bachert, C; Baena-Cagnani, C E; Bai, C; Baigenzhin, A; Barbara, C; Barnes, P J; Bateman, E D; Beck, L; Bedbrook, A; Bel, E H; Benezet, O; Bennoor, K S; Benson, M; Bernabeu-Wittel, M; Bewick, M; Bindslev-Jensen, C; Blain, H; Blasi, F; Bonini, M; Bonini, S; Boulet, L P; Bourdin, A; Bourret, R; Bousquet, P J; Brightling, C E; Briggs, A; Brozek, J; Buhl, R; Bush, A; Caimmi, D; Calderon, M; Calverley, P; Camargos, P A; Camuzat, T; Canonica, G W; Carlsen, K H; Casale, T B; Cazzola, M; Cepeda Sarabia, A M; Cesario, A; Chen, Y Z; Chkhartishvili, E; Chavannes, N H; Chiron, R; Chuchalin, A; Chung, K F; Cox, L; Crooks, G; Crooks, M G; Cruz, A A; Custovic, A; Dahl, R; Dahlen, S E; De Blay, F; Dedeu, T; Deleanu, D; Demoly, P; Devillier, P; Didier, A; Dinh-Xuan, A T; Djukanovic, R; Dokic, D; Douagui, H; Dubakiene, R; Eglin, S; Elliot, F; Emuzyte, R; Fabbri, L; Fink Wagner, A; Fletcher, M; Fokkens, W J; Fonseca, J; Franco, A; Frith, P; Furber, A; Gaga, M; Garcés, J; Garcia-Aymerich, J; Gamkrelidze, A; Gonzales-Diaz, S; Gouzi, F; Guzmán, M A; Haahtela, T; Harrison, D; Hayot, M; Heaney, L G; Heinrich, J; Hellings, P W; Hooper, J; Humbert, M; Hyland, M; Iaccarino, G; Jakovenko, D; Jardim, J R; Jeandel, C; Jenkins, C; Johnston, S L; Jonquet, O; Joos, G; Jung, K S; Kalayci, O; Karunanithi, S; Keil, T; Khaltaev, N; Kolek, V; Kowalski, M L; Kull, I; Kuna, P; Kvedariene, V; Le, L T; Lodrup Carlsen, K C; Louis, R; MacNee, W; Mair, A; Majer, I; Manning, P; de Manuel Keenoy, E; Masjedi, M R; Melen, E; Melo-Gomes, E; Menzies-Gow, A; Mercier, G; Mercier, J; Michel, J P; Miculinic, N; Mihaltan, F; Milenkovic, B; Molimard, M; Momas, I; Montilla-Santana, A; Morais-Almeida, M; Morgan, M; N'Diaye, M; Nafti, S; Nekam, K; Neou, A; Nicod, L; O'Hehir, R; Ohta, K; Paggiaro, P; Palkonen, S; Palmer, S; Papadopoulos, N G; Papi, A; Passalacqua, G; Pavord, I; Pigearias, B; Plavec, D; Postma, D S; Price, D; Rabe, K F; Radier Pontal, F; Redon, J; Rennard, S; Roberts, J; Robine, J M; Roca, J; Roche, N; Rodenas, F; Roggeri, A; Rolland, C; Rosado-Pinto, J; Ryan, D; Samolinski, B; Sanchez-Borges, M; Schünemann, H J; Sheikh, A; Shields, M; Siafakas, N; Sibille, Y; Similowski, T; Small, I; Sola-Morales, O; Sooronbaev, T; Stelmach, R; Sterk, P J; Stiris, T; Sud, P; Tellier, V; To, T; Todo-Bom, A; Triggiani, M; Valenta, R; Valero, A L; Valiulis, A; Valovirta, E; Van Ganse, E; Vandenplas, O; Vasankari, T; Vestbo, J; Vezzani, G; Viegi, G; Visier, L; Vogelmeier, C; Vontetsianos, T; Wagstaff, R; Wahn, U; Wallaert, B; Whalley, B; Wickman, M; Williams, D M; Wilson, N; Yawn, B P; Yiallouros, P K; Yorgancioglu, A; Yusuf, O M; Zar, H J; Zhong, N; Zidarn, M; Zuberbier, T

    2014-08-01

    The objective of Integrated Care Pathways for Airway Diseases (AIRWAYS-ICPs) is to launch a collaboration to develop multi-sectoral care pathways for chronic respiratory diseases in European countries and regions. AIRWAYS-ICPs has strategic relevance to the European Union Health Strategy and will add value to existing public health knowledge by: 1) proposing a common framework of care pathways for chronic respiratory diseases, which will facilitate comparability and trans-national initiatives; 2) informing cost-effective policy development, strengthening in particular those on smoking and environmental exposure; 3) aiding risk stratification in chronic disease patients, using a common strategy; 4) having a significant impact on the health of citizens in the short term (reduction of morbidity, improvement of education in children and of work in adults) and in the long-term (healthy ageing); 5) proposing a common simulation tool to assist physicians; and 6) ultimately reducing the healthcare burden (emergency visits, avoidable hospitalisations, disability and costs) while improving quality of life. In the longer term, the incidence of disease may be reduced by innovative prevention strategies. AIRWAYSICPs was initiated by Area 5 of the Action Plan B3 of the European Innovation Partnership on Active and Healthy Ageing. All stakeholders are involved (health and social care, patients, and policy makers).

  3. Knowledge of nursing students about central venous catheters.

    PubMed

    Mlinar, Suzana; Malnarsić, Rosanda Rasković

    2012-04-01

    Central venous catheters (CVC) are at the crucial importance, particulary in the intensive therapy units. In order to handle a CVC safely, nursing students need to acquire theoretical and practical knowledge during the course of their studies. The aim of the study was to establish theoretical knowledge of nursing students about the procedures of nurses in placing and removing a central venous catheter (CVC), dressing the catheter entry point, the reasons for measuring central venous pressure (CVP), possible complications and risk factors for developing infections related to CVC. The questionnaire developed specifically for this cross-sectionl study was handed out to 87 full-time students and 57 part-time students. The results show that all the surveyed nursing students know why chest radiography is carried out when inserting a catheter, have relatively good knowledge of CVC insertion points, procedures carried out in case of a suspected catheter sepsis and complications and risk factors for the development of infections related to CVC. However, the study show that the majority of students have insufficient knowledge of the procedures accompanying insertion of a catheter, signs that indicate correct functioning of CVC, frequency of flushing a catheter when it is not in use and the reasons for introducing an implanted CVC. Based on the results of the study it can be concluded that the second-year nursing students have insufficient knowledge of CVC. In order to correctly and safely handle a CVC, good theoretical knowledge and relevant practical experience are needed. The authors therefore believe that, in future, the classes should be organized in smaller groups with step-by-step demonstrations of individual procedures in handling a CVC, and the students encouraged to learn as actively as possible.

  4. Assessment of upper airway mechanics during sleep.

    PubMed

    Farré, Ramon; Montserrat, Josep M; Navajas, Daniel

    2008-11-30

    Obstructive sleep apnea, which is the most prevalent sleep breathing disorder, is characterized by recurrent episodes of upper airway collapse and reopening. However, the mechanical properties of the upper airway are not directly measured in routine polysomnography because only qualitative sensors (thermistors for flow and thoraco-abdominal bands for pressure) are used. This review focuses on two techniques that quantify upper airway obstruction during sleep. A Starling model of collapsible conduit allows us to interpret the mechanics of the upper airway by means of two parameters: the critical pressure (Pcrit) and the upstream resistance (Rup). A simple technique to measure Pcrit and Rup involves the application of different levels of continuous positive airway pressure (CPAP) during sleep. The forced oscillation technique is another non-invasive procedure for quantifying upper airway impedance during the breathing cycle in sleep studies. The latest developments in these two methods allow them to be easily applied on a routine basis in order to more fully characterize upper airway mechanics in patients with sleep breathing disorders.

  5. Catheter-associated bloodstream infections in pediatric hematology-oncology patients: factors associated with catheter removal and recurrence.

    PubMed

    Adler, Amos; Yaniv, Isaac; Solter, Ester; Freud, Enrique; Samra, Zmira; Stein, Jerry; Fisher, Salvador; Levy, Itzhak

    2006-01-01

    The aims of this study were to analyze the factors associated with antibiotic failure leading to tunneled central venous catheter (CVC) removal during catheter-associated bloodstream infections (CABSIs) and with recurrence and reinfection in children with cancer. All cases of CABSI in patients attending the Department of Pediatric Hematology-Oncology between November 2000 and November 2003 were reviewed. A total of 207 episodes of CABSI, including multiple episodes involving the same catheter, were identified in 146 of 410 tunneled CVCs (167 Hickman, 243 implantable ports). The most common organism isolated was coagulase-negative Staphylococcus (CONS). The CVC was removed in 96 (46%) episodes. Hypotension, persistent bacteremia, previous stem cell transplantation, multiple CABSIs in the same CVC, exit-site infection, inappropriate empiric antibiotic therapy, and Candida infection were all significantly associated with increased risk of catheter removal (P < 0.05, odds ratios 7.81, 1.14, 2.22, 1.93, 3.04, 2.04 and 24.53, respectively). There were 12 episodes of recurrent infection, all except 1 caused by CONS (odds ratio 20.5, P = 0.006). Inappropriate empiric therapy, especially in implantable ports, was the only mutable risk factor for antibiotic failure. Because CONS was the predominant isolate in these devices, adding glycopeptides to the empiric therapy for suspected implantable-port CABSI might decrease the removal rate. This issue should be explored in future controlled trials.

  6. Post-procedural evaluation of catheter contact force characteristics

    NASA Astrophysics Data System (ADS)

    Koch, Martin; Brost, Alexander; Kiraly, Atilla; Strobel, Norbert; Hornegger, Joachim

    2012-03-01

    Minimally invasive catheter ablation of electric foci, performed in electrophysiology labs, is an attractive treatment option for atrial fibrillation (AF) - in particular if drug therapy is no longer effective or tolerated. There are different strategies to eliminate the electric foci inducing the arrhythmia. Independent of the particular strategy, it is essential to place transmural lesions. The impact of catheter contact force on the generated lesion quality has been investigated recently, and first results are promising. There are different approaches to measure catheter-tissue contact. Besides traditional haptic feedback, there are new technologies either relying on catheter tip-to-tissue contact force or on local impedance measurements at the tip of the catheter. In this paper, we present a novel tool for post-procedural ablation point evaluation and visualization of contact force characteristics. Our method is based on localizing ablation points set during AF ablation procedures. The 3-D point positions are stored together with lesion specific catheter contact force (CF) values recorded during the ablation. The force records are mapped to the spatial 3-D positions, where the energy has been applied. The tracked positions of the ablation points can be further used to generate a 3-D mesh model of the left atrium (LA). Since our approach facilitates visualization of different force characteristics for post-procedural evaluation and verification, it has the potential to improve outcome by highlighting areas where lesion quality may be less than desired.

  7. Innovating urinary catheter design: An introduction to the engineering challenge.

    PubMed

    Murphy, Cathy

    2018-05-01

    Every day, people around the world rely on intermittent and indwelling urinary catheters to manage bladder dysfunction, but the potential or actual harm caused by these devices is well-recognised. Current catheter designs can cause urinary tract infection and septicaemia, bladder and urethral trauma and indwelling devices frequently become blocked. Furthermore, the devices can severely disrupt users' lives, limiting their daily activities and can be costly to manage for healthcare providers. Despite this, little significant design innovation has taken place in the last 80 years. In this article current catheter designs and their limitations are reviewed, common catheter-associated problems are outlined and areas of design ripe for improvement proposed. The potential to relieve the individual and economic burden of catheter use is high.

  8. Spinal anaesthesia with a micro-catheter in high-risk patients undergoing colorectal cancer and other major abdominal surgery.

    PubMed

    Kumar, Chandra M; Corbett, William A; Wilson, Robert G

    2008-08-01

    Extended spinal anaesthesia using a spinal micro-catheter was used as a primary method of anaesthesia for elective colorectal cancer surgery in 68 high risk patients over a 14-year period in our institution. The technique was also useful in eight elective and 13 emergency abdominal surgeries. All patients suffered from severe chronic obstructive airway disease requiring multiple inhalers and drugs (ASA III). Thirty nine of these patients also suffered from angina, myocardial infarction, diabetes and other systemic diseases (ASA IV). Surgery included right hemicolectomy, left hemicolectomy, total colectomy, sigmoid colectomy, Hartman's resection, anterior resection of rectum, abdominoperineal resection, cholecystectomy (open and laparoscopic) and obstructed inguinal hernia requiring laparotomy. Spinal anaesthesia was performed under strict aseptic conditions with a 22 gauge spinal needle with a mixture consisting of 2.75ml of 0.5% heavy bupivacaine and 0.25ml of fentanyl (25microg). This was followed by placement of a spinal micro-catheter and the duration of anaesthesia was extended by intermittent injection of 0.5% isobaric bupivacaine. Brief hypotension occurred in 12.4% of patients during the establishment of anaesthetic block height to T6-7 and was duly treated with intravenous administration of fluid and ephedrine hydrochloride. Good anaesthesia resulted in all patients except for brief discomfort in some patients during hemicolectomy surgery possibly due to the dissection and traction on the peritoneum causing irritation to the diaphragm. The use of sedation was avoided. General anaesthesia was administered in one patient and this patient required postoperative ventilation and cardiovascular support in the Intensive Care Unit. The spinal micro-catheter was removed at the end of surgery. Postoperative pain relief was obtained by administering intravenous morphine through a patient controlled analgesia machine in the critical care ward area (High Dependency

  9. Emergency catheter ablation in critical patients

    PubMed Central

    Tebbenjohanns, Jürgen; Rühmkorf, Klaus

    2010-01-01

    Emergency catheter ablation is justified in critical patients with drug-refractory life-threatening arrhythmias. The procedure can be used for ablation of an accessory pathway in preexcitation syndrome with high risk of ventricular fibrillation and in patients with shock due to ischemic cardiomyopathy and incessant ventricular tachycardia. Emergency catheter ablation can also be justified in patients with an electrical storm of the implanted cardioverter-defibrillator or in patients with idiopathic ventricular fibrillation. PMID:20606793

  10. [Epidemiology of catheter-related infections in intensive care unit].

    PubMed

    Merrer, J

    2005-03-01

    Catheter-related infections remain an important cause of nosocomial infection in the ICU. They include colonization of the device, exit-site infection and catheter-related bloodstream infection with or without bacteraemia. Data from clinical studies and surveillance networks should be compared cautiously due to important methodological differences and wide variations of device-utilization ratio between units or countries. In France, two regional networks (C-CLIN Paris-Nord and C-CLIN Sud-Est) produced comparable and reproducible results. Colonization represents five-six cases per 1000 catheter-days and bacteraemia represents one case per 1000 catheter-days. Incidence rates from North American studies are usually four to five times higher. Numerous risk factors have been identified. Some of them could be used to stratify patients according to risk of catheter-related infection and to allow more valid comparison between ICU's performances. Participation of French ICUs to the recent national surveillance networks (REA RAISIN and REACAT RAISIN) should be encouraged.

  11. Peritoneal dialysis catheter implantation: avoiding problems and optimizing outcomes.

    PubMed

    Crabtree, John H

    2015-01-01

    The success of peritoneal dialysis (PD) as renal replacement therapy is dependent upon the patient having a functional long-term peritoneal access. There are a number of identified best practices that must be adhered to during PD catheter placement to achieve a durable and infection-resistant access. The clinical setting, available resources, and the employed catheter insertion method may not always permit complete adherence to these practices; however, an attempt should be made to comply with them as closely as possible. Although omission of any one of the practices can lead to catheter loss, departures from some are committed more frequently, manifesting as commonly occurring clinical problems, such as drain pain, catheter tip migration, omental entrapment, pericatheter leaks and hernias, and poor exit-site location. Understanding the technical pitfalls in PD catheter placement that lead to these problems, enable the provider to modify practice habits to avoid them and optimize outcomes. © 2014 Wiley Periodicals, Inc.

  12. Central venous catheter integrity during mechanical power injection of iodinated contrast medium.

    PubMed

    Macha, Douglas B; Nelson, Rendon C; Howle, Laurens E; Hollingsworth, John W; Schindera, Sebastian T

    2009-12-01

    To evaluate a widely used nontunneled triple-lumen central venous catheter in order to determine whether the largest of the three lumina (16 gauge) can tolerate high flow rates, such as those required for computed tomographic angiography. Forty-two catheters were tested in vitro, including 10 new and 32 used catheters (median indwelling time, 5 days). Injection pressures were continuously monitored at the site of the 16-gauge central venous catheter hub. Catheters were injected with 300 and 370 mg of iodine per milliliter of iopamidol by using a mechanical injector at increasing flow rates until the catheter failed. The infusion rate, hub pressure, and location were documented for each failure event. The catheter pressures generated during hand injection by five operators were also analyzed. Mean flow rates and pressures at failure were compared by means of two-tailed Student t test, with differences considered significant at P < .05. Injections of iopamidol with 370 mg of iodine per milliliter generate more pressure than injections of iopamidol with 300 mg of iodine per milliliter at the same injection rate. All catheters failed in the tubing external to the patient. The lowest flow rate at which catheter failure occurred was 9 mL/sec. The lowest hub pressure at failure was 262 pounds per square inch gauge (psig) for new and 213 psig for used catheters. Hand injection of iopamidol with 300 mg of iodine per milliliter generated peak hub pressures ranging from 35 to 72 psig, corresponding to flow rates ranging from 2.5 to 5.0 mL/sec. Indwelling use has an effect on catheter material property, but even for used catheters there is a substantial safety margin for power injection with the particular triple-lumen central venous catheter tested in this study, as the manufacturer's recommendation for maximum pressure is 15 psig.

  13. Catheter tip force transducer for cardiovascular research

    NASA Technical Reports Server (NTRS)

    Feldstein, C.; Lewis, G. W.; Silver, R. H.; Culler, V. H. (Inventor)

    1976-01-01

    A force transducer for measuring dynamic force activity within the heart of a subject essentially consists of a U-shaped beam of low elastic compliance material. Two lines extend from the beams's legs and a long coil spring is attached to the beam. A strain gauge is coupled to one of the beam's legs to sense deflections thereof. The beam with the tines and most of the spring are surrounded by a flexible tube, defining a catheter, which is insertable into a subject's heart through an appropriate artery. The tines are extractable from the catheter for implantation into the myocardium by pushing on the end of the spring which extends beyond the external end of the catheter.

  14. Percutaneous Management of Postoperative Duodenal Stump Leakage with Foley Catheter

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Oh, Jung Suk, E-mail: oj-cumc@daum.net; Lee, Hae Giu, E-mail: hgleehfh@catholic.ac.kr; Chun, Ho Jong

    2013-10-15

    Purpose: This study was designed to evaluate retrospectively the safety and efficacy of the percutaneous management of duodenal stump leakage with a Foley catheter after subtotal gastrectomy. Methods: Ten consecutive patients (M:F = 9:1, median age: 64 years) were included in this retrospective study. The duodenal stump leakages were diagnosed in all the patients within a median of 10 days (range, 6-20). At first, the patients underwent percutaneous drainage on the day of or the day after confirmation of the presence of duodenal stump leakage, and then the Foley catheters were replaced at a median of 9 days (range, 6-38)more » after the percutaneous drainage. Results: Foley catheters were placed successfully in the duodenal lumen of all the patients under a fluoroscopic guide. No complication was observed during and after the procedures in all the patients. All of the patients started a regular diet 1 day after the Foley catheter placement. The patients were discharged at a median of 7 days (range, 5-14) after the Foley catheter placement. The catheters were removed in an outpatient clinic 10-58 days (median, 28) after the Foley catheter placement. Conclusions: Fluoroscopy-guided percutaneous Foley catheter placement may be a safe and effective treatment option for postoperative duodenal stump leakage and may allow for shorter hospital stays, earlier oral intake, and more effective control of leakage sites.« less

  15. Urinary catheters: history, current status, adverse events and research agenda

    PubMed Central

    Feneley, Roger C. L.; Hopley, Ian B.; Wells, Peter N. T.

    2015-01-01

    Abstract For more than 3500 years, urinary catheters have been used to drain the bladder when it fails to empty. For people with impaired bladder function and for whom the method is feasible, clean intermittent self-catheterization is the optimal procedure. For those who require an indwelling catheter, whether short- or long-term, the self-retaining Foley catheter is invariably used, as it has been since its introduction nearly 80 years ago, despite the fact that this catheter can cause bacterial colonization, recurrent and chronic infections, bladder stones and septicaemia, damage to the kidneys, the bladder and the urethra, and contribute to the development of antibiotic resistance. In terms of medical, social and economic resources, the burden of urinary retention and incontinence, aggravated by the use of the Foley catheter, is huge. In the UK, the harm resulting from the use of the Foley catheter costs the National Health Service between £1.0–2.5 billion and accounts for ∼2100 deaths per year. Therefore, there is an urgent need for the development of an alternative indwelling catheter system. The research agenda is for the new catheter to be easy and safe to insert, either urethrally or suprapubically, to be retained reliably in the bladder and to be withdrawn easily and safely when necessary, to mimic natural physiology by filling at low pressure and emptying completely without damage to the bladder, and to have control mechanisms appropriate for all users. PMID:26383168

  16. Mechanical Properties of the Upper Airway

    PubMed Central

    Strohl, Kingman P.; Butler, James P.; Malhotra, Atul

    2013-01-01

    The importance of the upper airway (nose, pharynx, and larynx) in health and in the pathogenesis of sleep apnea, asthma, and other airway diseases, discussed elsewhere in the Comprehensive Physiology series, prompts this review of the biomechanical properties and functional aspects of the upper airway. There is a literature based on anatomic or structural descriptions in static circumstances, albeit studied in limited numbers of individuals in both health and disease. As for dynamic features, the literature is limited to studies of pressure and flow through all or parts of the upper airway and to the effects of muscle activation on such features; however, the links between structure and function through airway size, shape, and compliance remain a topic that is completely open for investigation, particularly through analyses using concepts of fluid and structural mechanics. Throughout are included both historically seminal references, as well as those serving as signposts or updated reviews. This article should be considered a resource for concepts needed for the application of biomechanical models of upper airway physiology, applicable to understanding the pathophysiology of disease and anticipated results of treatment interventions. PMID:23723026

  17. Fecal containment in bedridden patients: economic impact of 2 commercial bowel catheter systems.

    PubMed

    Kowal-Vem, Areta; Poulakidas, Stathis; Barnett, Barbara; Conway, Deborah; Culver, Daniel; Ferrari, Michelle; Potenza, Bruce; Koenig, Michael; Mah, John; Majewski, Mary; Morris, Linda; Powers, Jan; Stokes, Elizabeth; Tan, Michael; Salstrom, Sara-Jane; Zaletel, Cindy; Ambutas, Shirley; Casey, Kathleen; Stein, Jayne; DeSane, Mary; Berry, Kathy; Konz, Elizabeth C; Riemer, Michael R; Cullum, Malford E

    2009-05-01

    Fecal contamination is a major challenge in patients in acute/critical care settings that is associated with increased cost of care and supplies and with development of pressure ulcers, incontinence dermatitis, skin and soft tissue infections, and urinary tract infections. To assess the economic impact of fecal containment in bedridden patients using 2 different indwelling bowel catheters and to compare infection rates between groups. A multicenter, observational study was done at 12 US sites (7 that use catheter A, 5 that use catheter B). Patients were followed from insertion of an indwelling bowel catheter system until the patient left the acute/critical care unit or until 29 days after enrollment, whichever came first. Demographic data, frequency of bedding/dressing changes, incidence of infection, and Braden scores (risk of pressure ulcers) were recorded. The study included 146 bedridden patients (76 with catheter A, 70 with catheter B) who had similar Braden scores at enrollment. The rate of bedding/dressing changes per day differed significantly between groups (1.20 for catheter A vs 1.71 for catheter B; P = .004). According to a formula that accounted for personnel resources and laundry cycle costs, catheter A cost $13.94 less per patient per day to use than did catheter B. Catheter A was less likely than was catheter B to be removed during the observational period (P = .03). Observed infection rates were low. Catheter A may be more cost-effective than catheter B because it requires fewer unscheduled linen changes per patient day.

  18. [Small airway diseases and immune deficiency].

    PubMed

    Burgel, P-R; Bergeron, A; Knoop, C; Dusser, D

    2016-02-01

    Innate or acquired immune deficiency may show respiratory manifestations, often characterized by small airway involvement. The purpose of this article is to provide an overview of small airway disease across the major causes of immune deficiency. In patients with common variable immune deficiency, recurrent lower airway infections may lead to bronchiolitis and bronchiectasis. Follicular and/or granulomatous bronchiolitis of unknown origin may also occur. Bronchiolitis obliterans is the leading cause of death after the first year in patients with lung transplantation. Bronchiolitis obliterans also occurs in patients with allogeneic haematopoietic stem cell transplantation, especially in the context of systemic graft-versus-host disease. Small airway diseases have different clinical expression and pathophysiology across various causes of immune deficiency. A better understanding of small airways disease pathogenesis in these settings may lead to the development of novel targeted therapies. Copyright © 2015 SPLF. Published by Elsevier Masson SAS. All rights reserved.

  19. Effects of the tripeptide substance P antagonist, FR113680, on airway constriction and airway edema induced by neurokinins in guinea-pigs.

    PubMed

    Murai, M; Morimoto, H; Maeda, Y; Fujii, T

    1992-06-24

    FR113680 is a newly developed tripeptide substance P (SP) receptor antagonist. The effects of FR113680 on airway constriction and airway edema induced by neurokinins were investigated in guinea-pigs. In in vitro experiments, FR113680 inhibited the contraction of isolated guinea-pig trachea induced by SP and neurokinin A (NKA) in a dose-dependent manner with IC50 values of 2.3 x 10(-6) and 1.5 x 10(-5) M, respectively. The tracheal contraction induced by histamine and acetylcholine was not affected by FR113680. FR113680 (5 x 10(-5) M) also significantly inhibited the atropine-resistant contraction of isolated guinea-pig bronchi induced by electrical field stimulation. In in vivo experiments, FR113680 given i.v. inhibited SP-induced airway constriction in guinea-pigs at doses of 1 and 10 mg kg-1. However, FR113680 only inhibited NKA- and capsaicin-induced airway constriction by 40-50% even at a dose of 10 mg kg-1. FR113680 also inhibited SP-induced airway edema in guinea-pigs with the same potency as it inhibited SP-induced airway constriction. Histamine-induced airway constriction and airway edema were not affected at a dose of 10 mg kg-1. These results suggest that FR113680 preferentially inhibits responses induced by NK1 receptor activation (SP-induced airway constriction and airway edema), but is less effective on a NK2 receptor-induced response (airway constriction by NKA and neurogenic stimulation).

  20. How anaesthesiologists understand difficult airway guidelines-an interview study.

    PubMed

    Knudsen, Kati; Pöder, Ulrika; Nilsson, Ulrica; Högman, Marieann; Larsson, Anders; Larsson, Jan

    2017-11-01

    In the practice of anaesthesia, clinical guidelines that aim to improve the safety of airway procedures have been developed. The aim of this study was to explore how anaesthesiologists understand or conceive of difficult airway management algorithms. A qualitative phenomenographic design was chosen to explore anaesthesiologists' views on airway algorithms. Anaesthesiologists working in three hospitals were included. Individual face-to-face interviews were conducted. Four different ways of understanding were identified, describing airway algorithms as: (A) a law-like rule for how to act in difficult airway situations; (B) a cognitive aid, an action plan for difficult airway situations; (C) a basis for developing flexible, personal action plans for the difficult airway; and (D) the experts' consensus, a set of scientifically based guidelines for handling the difficult airway. The interviewed anaesthesiologists understood difficult airway management guidelines/algorithms very differently.

  1. SU-F-T-20: Novel Catheter Lumen Recognition Algorithm for Rapid Digitization

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dise, J; McDonald, D; Ashenafi, M

    Purpose: Manual catheter recognition remains a time-consuming aspect of high-dose-rate brachytherapy (HDR) treatment planning. In this work, a novel catheter lumen recognition algorithm was created for accurate and rapid digitization. Methods: MatLab v8.5 was used to create the catheter recognition algorithm. Initially, the algorithm searches the patient CT dataset using an intensity based k-means filter designed to locate catheters. Once the catheters have been located, seed points are manually selected to initialize digitization of each catheter. From each seed point, the algorithm searches locally in order to automatically digitize the remaining catheter. This digitization is accomplished by finding pixels withmore » similar image curvature and divergence parameters compared to the seed pixel. Newly digitized pixels are treated as new seed positions, and hessian image analysis is used to direct the algorithm toward neighboring catheter pixels, and to make the algorithm insensitive to adjacent catheters that are unresolvable on CT, air pockets, and high Z artifacts. The algorithm was tested using 11 HDR treatment plans, including the Syed template, tandem and ovoid applicator, and multi-catheter lung brachytherapy. Digitization error was calculated by comparing manually determined catheter positions to those determined by the algorithm. Results: he digitization error was 0.23 mm ± 0.14 mm axially and 0.62 mm ± 0.13 mm longitudinally at the tip. The time of digitization, following initial seed placement was less than 1 second per catheter. The maximum total time required to digitize all tested applicators was 4 minutes (Syed template with 15 needles). Conclusion: This algorithm successfully digitizes HDR catheters for a variety of applicators with or without CT markers. The minimal axial error demonstrates the accuracy of the algorithm, and its insensitivity to image artifacts and challenging catheter positioning. Future work to automatically place initial

  2. Gene Delivery to the Airway

    PubMed Central

    Keiser, Nicholas W.; Engelhardt, John F.

    2013-01-01

    This unit describes generation of and gene transfer to several commonly used airway models. Isolation and transduction of primary airway epithelial cells are first described. Next, the preparation of polarized airway epithelial monolayers is outlined. Transduction of these polarized cells is also described. Methods are presented for generation of tracheal xenografts as well as both ex vivo and in vivo gene transfer to these xenografts. Finally, a method for in vivo gene delivery to the lungs of rodents is included. Methods for evaluating transgene expression are given in the support protocols. PMID:23853081

  3. Catheter-associated bloodstream infections in pediatric hematology-oncology patients.

    PubMed

    Celebi, Solmaz; Sezgin, Melike Evim; Cakır, Deniz; Baytan, Birol; Demirkaya, Metin; Sevinir, Betul; Bozdemir, Sefika Elmas; Gunes, Adalet Meral; Hacimustafaoglu, Mustafa

    2013-04-01

    Catheter-associated bloodstream infections (CABSIs) are common complications encountered with cancer treatment. The aims of this study were to analyze the factors associated with recurrent infection and catheter removal in pediatric hematology-oncology patients. All cases of CABSIs in patients attending the Department of Pediatric Hematology-Oncology between January 2008 and December 2010 were reviewed. A total of 44 episodes of CABSIs, including multiple episodes involving the same catheter, were identified in 31 children with cancer. The overall CABSIs rate was 7.4 infections per 1000 central venous catheter (CVC) days. The most frequent organism isolated was coagulase-negative Staphylococcus (CONS). The CVC was removed in nine (20.4%) episodes. We found that hypotension, persistent bacteremia, Candida infection, exit-side infection, neutropenia, and prolonged duration of neutropenia were the factors for catheter removal. There were 23 (52.2%) episodes of recurrence or reinfection. Mortality rate was found to be 9.6% in children with CABSIs. In this study, we found that CABSIs rate was 7.4 infections per 1000 catheter-days. CABSIs rates in our hematology-oncology patients are comparable to prior reports. Because CONS is the most common isolated microorganism in CABSIs, vancomycin can be considered part of the initial empirical regimen.

  4. Heated humidification versus heat and moisture exchangers for ventilated adults and children.

    PubMed

    Kelly, Margaret; Gillies, Donna; Todd, David A; Lockwood, Catherine

    2010-04-14

    Humidification by artificial means must be provided when the upper airway is bypassed during mechanical ventilation. Heated humidification (HH) and heat and moisture exchangers (HME) are the most commonly used types of artificial humidification in this situation. To determine whether HHs or HMEs are more effective in preventing mortality and other complications in people who are mechanically ventilated. We searched the Cochrane Central Register of Controlled Trials (The Cochrane Library 2010, Issue 4) and MEDLINE, EMBASE and CINAHL (January, 2010) to identify relevant randomized controlled trials (RCTs). We included RCTs comparing heat and moisture exchangers (HMEs) to heated humidifiers (HHs) in mechanically ventilated adults and children. We included randomized crossover studies. We assessed the quality of each study and extracted the relevant data. Where appropriate, results from relevant studies were meta-analysed for individual outcomes. We included 33 trials with 2833 participants, 25 studies were parallel group design (n = 2710) and eight crossover design (n = 123). Only three included studies reported data for infants or children. There was no overall effect on artificial airway occlusion, mortality, pneumonia, or respiratory complications; however, the PaCO(2) and minute ventilation were increased when HMEs were compared to HHs and body temperature was lower. The cost of HMEs was lower in all studies that reported this outcome. There was some evidence that hydrophobic HMEs may reduce the risk of pneumonia and that blockages of artificial airways may be increased with the use of HMEs in certain subgroups of patients. There is little evidence of an overall difference between HMEs and HHs. However, hydrophobic HMEs may reduce the risk of pneumonia and the use of an HME may increase artificial airway occlusion in certain subgroups of patients. Therefore, HMEs may not be suitable for patients with limited respiratory reserve or prone to airway blockage. Further

  5. Do catheter washouts extend patency time in long-term indwelling urethral catheters? A randomized controlled trial of acidic washout solution, normal saline washout, or standard care.

    PubMed

    Moore, Katherine N; Hunter, Kathleen F; McGinnis, Rosemary; Bacsu, Chasta; Fader, Mandy; Gray, Mikel; Getliffe, Kathy; Chobanuk, Janice; Puttagunta, Lakshmi; Voaklander, Donald C

    2009-01-01

    Blockage of long-term indwelling catheters with mineral deposit is an ongoing management issue, but evidence on optimal management is lacking. Our purpose was to examine whether catheter washouts prevent or reduce catheter blockage. A multisite randomized controlled trial. Adults with long-term indwelling catheters that required changing every 3 weeks or less, living in the community, and requiring supportive or continuing care were recruited. Participants were randomly assigned to 1 of 3 groups: control (usual care, no washout), saline washout, or commercially available acidic washout solution (Contisol Maelor Pharmaceuticals Ltd, Wrexham, UK). At baseline visit, the catheter was changed and participants were followed weekly for 8 weeks, with checks for catheter patency and urine pH. Participants randomized to saline or commercial solution had a weekly washout with the appropriate solution. Endpoints were 8 weeks (completion data), 3 or more catheter changes in the 8-week period, or symptomatic urinary tract infection (UTI) requiring antibiotics. The study hypothesis was that catheter life would be extended by 25% in the commercial solution group. It was not possible to blind participants or research nurses to washout versus no intervention, but participants in the saline and washout solution groups were blinded to solution type. One hundred twelve potential participants were screened; 73 were enrolled, randomized, and included in the final analysis. Of these, 53 completed the full 8 weeks of data collection; 16 terminated early because of 3 catheter changes or self-reported 'UTI'. Other reasons for termination were hematuria, latex sensitivity, deceased/severe illness, or personal choice. Analysis of variance was used to analyze mean differences on demographic variables and mean number of weeks in study. Kaplan-Meier survival curve analysis showed no statistical difference between the groups in time to first catheter change. At this time, the evidence is

  6. A pilot study to assess adductor canal catheter tip migration in a cadaver model.

    PubMed

    Leng, Jody C; Harrison, T Kyle; Miller, Brett; Howard, Steven K; Conroy, Myles; Udani, Ankeet; Shum, Cynthia; Mariano, Edward R

    2015-04-01

    An adductor canal catheter may facilitate early ambulation after total knee arthroplasty, but there is concern over preoperative placement since intraoperative migration of catheters may occur from surgical manipulation and result in ineffective analgesia. We hypothesized that catheter type and subcutaneous tunneling may influence tip migration for preoperatively inserted adductor canal catheters. In a male unembalmed human cadaver, 20 catheter insertion trials were divided randomly into one of four groups: flexible epidural catheter either tunneled or not tunneled; or rigid stimulating catheter either tunneled or not tunneled. Intraoperative patient manipulation was simulated by five range-of-motion exercises of the knee. Distance and length measurements were performed by a blinded regional anesthesiologist. Changes in catheter tip to nerve distance (p = 0.225) and length of catheter within the adductor canal (p = 0.467) were not different between the four groups. Two of five non-tunneled stimulating catheters (40 %) were dislodged compared to 0/5 in all other groups (p = 0.187). A cadaver model may be useful for assessing migration of regional anesthesia catheters; catheter type and subcutaneous tunneling may not affect migration of adductor canal catheters based on this preliminary study. However, future studies involving a larger sample size, actual patients, and other catheter types are warranted.

  7. Urethral versus suprapubic catheter: choosing the best bladder management for male spinal cord injury patients with indwelling catheters.

    PubMed

    Katsumi, H K; Kalisvaart, J F; Ronningen, L D; Hovey, R M

    2010-04-01

    Bladder management for male patients with spinal cord injury (SCI) challenges the urologist to work around physical and social restrictions set forth by each patient. The objective of this study was to compare the complications associated with urethral catheter (UC) versus suprapubic tube (SPT) in patients with SCI. A retrospective review of records at Long Beach Veterans Hospital was carried out to identify SCI patients managed with SPT or UC. Chart review identified morbidities including urinary tract infection (UTI), bladder stones, renal calculi, urethral complications, scrotal abscesses, epididymitis, gross hematuria and cancer. Serum creatinine measurements were evaluated to determine whether renal function was maintained. In all, 179 patients were identified. There was no significant difference between the two catheter groups in any areas in which they could be compared. There were catheter-specific complications specific to each group that could not be compared. These included erosion in the UC group and urethral leak, leakage from the SPT and SPT revision in the SPT group. Average serum creatinine for the UC and SPT groups was 0.74 and 0.67 mg per 100 ml, respectively. SCI patients with a chronic catheter have similar complication rates of UTIs, recurrent bladder/renal calculi and cancer. Urethral and scrotal complications may be higher with UC; however, morbidity from SPT-specific procedures may offset benefits from SPT. Serum creatinine was maintained in both groups. Overall, bladder management for patients with chronic indwelling catheters should be selected on the basis of long-term comfort for the patient and a physician mind-set that allows flexibility in managing these challenges.

  8. Are new supraglottic airway devices, tracheal tubes and airway viewing devices cost-effective?

    PubMed

    Slinn, Simon J; Froom, Stephen R; Stacey, Mark R W; Gildersleve, Christopher D

    2015-01-01

    Over the past two decades, a plethora of new airway devices has become available to the pediatric anesthetist. While all have the laudable intention of improving patient care and some have proven clinical benefits, these devices are often costly and at times claims of an advantage over current equipment and techniques are marginal. Supraglottic airway devices are used in the majority of pediatric anesthetics delivered in the U.K., and airway-viewing devices provide an alternative for routine intubation as well as an option in the management of the difficult airway. Yet hidden beneath the convenience of the former and the technology of the latter, the impact on basic airway skills with a facemask and the lack of opportunities to fine-tune the core skill of intubation represent an unrecognised and unquantifiable cost. A judgement on this value must be factored into the absolute purchase cost and any potential benefits to the quality of patient care, thus blurring any judgement on cost-effectiveness that we might have. An overall value on cost-effectiveness though not in strict monetary terms can then be ascribed. In this review, we evaluate the role of these devices in the care of the pediatric patient and attempt to balance the advantages they offer against the cost they incur, both financial and environmental, and in any quality improvement they might offer in clinical care. © 2014 John Wiley & Sons Ltd.

  9. How anaesthesiologists understand difficult airway guidelines—an interview study

    PubMed Central

    Knudsen, Kati; Nilsson, Ulrica; Larsson, Anders; Larsson, Jan

    2017-01-01

    Background In the practice of anaesthesia, clinical guidelines that aim to improve the safety of airway procedures have been developed. The aim of this study was to explore how anaesthesiologists understand or conceive of difficult airway management algorithms. Methods A qualitative phenomenographic design was chosen to explore anaesthesiologists’ views on airway algorithms. Anaesthesiologists working in three hospitals were included. Individual face-to-face interviews were conducted. Results Four different ways of understanding were identified, describing airway algorithms as: (A) a law-like rule for how to act in difficult airway situations; (B) a cognitive aid, an action plan for difficult airway situations; (C) a basis for developing flexible, personal action plans for the difficult airway; and (D) the experts’ consensus, a set of scientifically based guidelines for handling the difficult airway. Conclusions The interviewed anaesthesiologists understood difficult airway management guidelines/algorithms very differently. PMID:29299973

  10. [Central venous catheter-related infections in critically ill patients].

    PubMed

    Diener, J R; Coutinho, M S; Zoccoli, C M

    1996-01-01

    To determine incidence rate, etiology and risk factors for central venous catheter (CVC)-related infections in critically-ill patients, a prospective cohort study was conducted in the general Intensive Care Unit (ICU) of a 212 bed Hospital in Florianópolis, Brazil. Patients admitted to ICU between May 1993 and February 1994, exposed to short-term CVC, were included in the study. Quantitative skin culture at CVC insertion site, semi-quantitative CVC tip culture, quantitative hub culture, and peripheral blood-culture were done. Results were submitted to univariate and multivariate analysis. Fifty-seven catheterization periods were analysed in 51 patients. The incidence rate was 21.1% (33.1 per 1,000 catheter-days) for local infection, and 8.7% (14.1 per 1,000 catheter-days) for catheter-associated bacteremia. The skin at the insertion site was colonized in 32.7% and the hub in 29.1% of the patients respectively. Potential sources of infection were the skin in 41.2% of the cases, the hub in 29.4%, remote site in 5.9% and unknown in 23.5%. The hub was implicated in 60% of the catheter-associated bacteremias. Coagulase-negative staphylococci were the main isolates. Another intravascular device and purulence at the insertion site were independently associated with local infection. Insertion at internal jugular site and hub colonization were independently associated with bacteremia. Catheter-associated bacteremia is a major complication of central venous catheterization in critically-ill patients. Internal jugular insertion and CVC hub colonization are important risk factors for significant catheter-related infections.

  11. Multiple Coaxial Catheter System for Reliable Access in Interventional Stroke Therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kulcsar, Zsolt, E-mail: kulcsarzsolt22@gmail.com; Yilmaz, Hasan; Bonvin, Christophe

    2010-12-15

    In some patients with acute cerebral vessel occlusion, navigating mechanical thrombectomy systems is difficult due to tortuous anatomy of the aortic arch, carotid arteries, or vertebral arteries. Our purpose was to describe a multiple coaxial catheter system used for mechanical revascularization that helps navigation and manipulations in tortuous vessels. A triple or quadruple coaxial catheter system was built in 28 consecutive cases presenting with acute ischemic stroke. All cases were treated by mechanical thrombectomy with the Penumbra System. In cases of unsuccessful thrombo-aspiration, additional thrombolysis or angioplasty with stent placement was used for improving recanalization. The catheter system consisted ofmore » an outermost 8-Fr and an intermediate 6-Fr guiding catheter, containing the inner Penumbra reperfusion catheters. The largest, 4.1-Fr, reperfusion catheter was navigated over a Prowler Select Plus microcatheter. The catheter system provided access to reach the cerebral lesions and provided stability for the mechanically demanding manipulations of thromboaspiration and stent navigation in all cases. Apart from their mechanical role, the specific parts of the system could also provide access to different types of interventions, like carotid stenting through the 8-Fr guiding catheter and intracranial stenting and thrombolysis through the Prowler Select Plus microcatheter. In this series, there were no complications related to the catheter system. In conclusion, building up a triple or quadruple coaxial system proved to be safe and efficient in our experience for the mechanical thrombectomy treatment of acute ischemic stroke.« less

  12. Humidification and heating of inhaled gas in patients with artificial airway. A narrative review.

    PubMed

    Plotnikow, Gustavo Adrián; Accoce, Matias; Navarro, Emiliano; Tiribelli, Norberto

    2018-03-01

    Instrumentation of the airways in critical patients (endotracheal tube or tracheostomy cannula) prevents them from performing their function of humidify and heating the inhaled gas. In addition, the administration of cold and dry medical gases and the high flows that patients experience during invasive and non-invasive mechanical ventilation generate an even worse condition. For this reason, a device for gas conditioning is needed, even in short-term treatments, to avoid potential damage to the structure and function of the respiratory epithelium. In the field of intensive therapy, the use of heat and moisture exchangers is common for this purpose, as is the use of active humidification systems. Acquiring knowledge about technical specifications and the advantages and disadvantages of each device is needed for proper use since the conditioning of inspired gases is a key intervention in patients with artificial airway and has become routine care. Incorrect selection or inappropriate configuration of a device can have a negative impact on clinical outcomes. The members of the Capítulo de Kinesiología Intensivista of the Sociedad Argentina de Terapia Intensiva conducted a narrative review aiming to show the available evidence regarding conditioning of inhaled gas in patients with artificial airways, going into detail on concepts related to the working principles of each one.

  13. Design, development and evaluation of a compact telerobotic catheter navigation system.

    PubMed

    Tavallaei, Mohammad Ali; Gelman, Daniel; Lavdas, Michael Konstantine; Skanes, Allan C; Jones, Douglas L; Bax, Jeffrey S; Drangova, Maria

    2016-09-01

    Remote catheter navigation systems protect interventionalists from scattered ionizing radiation. However, these systems typically require specialized catheters and extensive operator training. A new compact and sterilizable telerobotic system is described, which allows remote navigation of conventional tip-steerable catheters, with three degrees of freedom, using an interface that takes advantage of the interventionalist's existing dexterity skills. The performance of the system is evaluated ex vivo and in vivo for remote catheter navigation and ablation delivery. The system has absolute errors of 0.1 ± 0.1 mm and 7 ± 6° over 100 mm of axial motion and 360° of catheter rotation, respectively. In vivo experiments proved the safety of the proposed telerobotic system and demonstrated the feasibility of remote navigation and delivery of ablation. The proposed telerobotic system allows the interventionalist to use conventional steerable catheters; while maintaining a safe distance from the radiation source, he/she can remotely navigate the catheter and deliver ablation lesions. Copyright © 2015 John Wiley & Sons, Ltd. Copyright © 2015 John Wiley & Sons, Ltd.

  14. Nerve growth factor-enhanced airway responsiveness involves substance P in ferret intrinsic airway neurons.

    PubMed

    Wu, Z-X; Dey, R D

    2006-07-01

    Nerve growth factor (NGF), a member of the neurotrophin family, enhances synthesis of neuropeptides in sensory and sympathetic neurons. The aim of this study was to examine the effect of NGF on airway responsiveness and determine whether these effects are mediated through synthesis and release of substance P (SP) from the intrinsic airway neurons. Ferrets were instilled intratracheally with NGF or saline. Tracheal smooth muscle contractility to methacholine and electrical field stimulation (EFS) was assessed in vitro. Contractions of isolated tracheal smooth muscle to EFS at 10 and 30 Hz were significantly increased in the NGF treatment group (10 Hz: 33.57 +/- 2.44%; 30 Hz: 40.12 +/- 2.78%) compared with the control group (10 Hz: 27.24 +/- 2.14%; 30 Hz: 33.33 +/- 2.31%). However, constrictive response to cholinergic agonist was not significantly altered between the NGF treatment group and the control group. The NGF-induced modulation of airway smooth muscle to EFS was maintained in tracheal segments cultured for 24 h, a procedure that causes a significant anatomic and functional loss of SP-containing sensory fibers while maintaining viability of intrinsic airway neurons. The number of SP-containing neurons in longitudinal trunk and superficial muscular plexus and SP nerve fiber density in tracheal smooth muscle all increased significantly in cultured trachea treated with NGF. Pretreatment with CP-99994, an antagonist of neurokinin 1 receptor, attenuated the NGF-induced increased contraction to EFS in cultured segments but had no effect in saline controls. These results show that the NGF-enhanced airway smooth muscle contractile responses to EFS are mediated by the actions of SP released from intrinsic airway neurons.

  15. Air-Q intubating laryngeal airway: A study of the second generation supraglottic airway device.

    PubMed

    Attarde, Viren Bhaskar; Kotekar, Nalini; Shetty, Sarika M

    2016-05-01

    Air-Q intubating laryngeal mask airway (ILA) is used as a supraglottic airway device and as a conduit for endotracheal intubation. This study aims to assess the efficacy of the Air-Q ILA regarding ease of insertion, adequacy of ventilation, rate of successful intubation, haemodynamic response and airway morbidity. Sixty patients presenting for elective surgery at our Medical College Hospital were selected. Following adequate premedication, baseline vital parameters, pulse rate and blood pressure were recorded. Air-Q size 3.5 for patients 50-70 kg and size 4.5 for 70-100 kg was selected. After achieving adequate intubating conditions, Air-Q ILA was introduced. Confirming adequate ventilation, appropriate sized endotracheal tube was advanced through the Air-Q blindly to intubate the trachea. Placement of the endotracheal tube in trachea was confirmed. Air-Q ILA was successfully inserted in 88.3% of patients in first attempt and 11.7% patients in second attempt. Ventilation was adequate in 100% of patients. Intubation was successful in 76.7% of patients with Air-Q ILA. 23.3% of patients were intubated by direct laryngoscopy following failure with two attempts using Air-Q ILA. Post-intubation the change in heart rate was statistically significant (P < 0.0001). 10% of patients were noted to have a sore throat and 5% of patients had mild airway trauma. Air-Q ILA is a reliable device as a supraglottic airway ensuring adequate ventilation as well as a conduit for endotracheal intubation. It benefits the patient by avoiding the stress of direct laryngoscopy and is also superior alternative device for use in a difficult airway.

  16. In situ diagnostic methods for catheter related bloodstream infection in burns patients: A pilot study.

    PubMed

    Evans, O; Gowardman, J; Rabbolini, D; McGrail, M; Rickard, C M

    2016-03-01

    One of the most common and potentially fatal complications in critically ill burns patients is catheter related bloodstream infection (CR-BSI). Lack of in situ diagnostic techniques requires device removal if CR-BSI is suspected with 75-85% of catheters withdrawn unnecessarily. To assess the sensitivity, specificity and accuracy of two in situ diagnostic methods for CR-BSI in an adult ICU burns population: Differential Time to Positivity (DTP) and Semi-Quantitative Superficial Cultures (SQSC). Both arterial (AC) and central venous (CVC) catheters were studied. On clinicians' suspicion of CR-BSI, the CVC and AC were removed. Superficial semi-quantitative cultures were taken by removing the dressings and swabbing within a 3cm radius of the CVC and AC insertion sites, as well as inside each hub of the CVC and AC. Peripheral blood was taken for qualitative culture and the catheter tip sent for semi-quantitative culture. DTP was considered positive if culture of lumen blood became positive at least 120min before peripheral blood with an identical pathogen. Superficial and tip cultures were identified as positive if ≥15 CFUs were grown. CR-BSI was confirmed when both catheter tip culture and peripheral blood culture were positive with the same micro-organism. Sixteen patients (88% male) with an APACHE II score of 22.0 (7.3) were enrolled. The mean age was 45.7 (16.9) years with mean total burn surface area 32.9 (19.4)%. Fifty percent had airway burns. ICU stay was 19.9 (11.1) days. All 16 survived ICU discharge with a hospital survival of 93%. There were 20 episodes of CR-BSI in these 16 patients. For these 20 episodes the exposure time (line days) was 113.15. The CR-BSI rate was 15.6 per 1000 catheter days (95% CI 1.9-56.4). For diagnosis of CR-BSI in either AC and CVC, SQSC had a sensitivity of 50% [95% CI 3-97], specificity 83.3% [95% CI 67-93], PPV 14.3 [95% CI 1-58], NPV 96.8 [95% CI 81-100], accuracy of 81.6% [95%CI 65-92] and diagnostic odds ratio 5.0 [95% CI 0

  17. Utility and safety of Hickman catheters for venous access after bone marrow transplantation.

    PubMed

    Kumagai, T; Sakamaki, H; Tanikawa, S; Akiyama, H; Maeda, Y; Sasaki, T; Tsuzuki, S; Takamoto, S; Takahashi, K; Onozawa, Y

    1998-03-01

    Hickman catheters are useful for vascular access after bone marrow transportation because they can handle large volume and allow for easy transfusions and blood drawing through wide double lumens making it easier to case for patients under sterile conditions in a clean room. However, the safety of Hickman catheters as compared to Silastic catheters in marrow transplants has never been discussed. We therefore retrospectively reviewed the complications of two catheters in 71 allogeneic bone marrow transplant recipients between September 1986 and August 1994. The complication and infection rates of Hickman catheters were 0.21 and 0.09 per 100 device-life days, and rate of temperature >38 degrees C during leukocytopenia (<1,000 white blood cells) was 0.18. These rates were not different from those of Silastic catheters suggesting that Hickman catheters are safe and acceptable in marrow transplantation. The benefits and drawbacks of Hickman catheters relevant to catheter choice were also discussed.

  18. Vascular Access Tracking System: a Web-Based Clinical Tracking Tool for Identifying Catheter Related Blood Stream Infections in Interventional Radiology Placed Central Venous Catheters.

    PubMed

    Morrison, James; Kaufman, John

    2016-12-01

    Vascular access is invaluable in the treatment of hospitalized patients. Central venous catheters provide a durable and long-term solution while saving patients from repeated needle sticks for peripheral IVs and blood draws. The initial catheter placement procedure and long-term catheter usage place patients at risk for infection. The goal of this project was to develop a system to track and evaluate central line-associated blood stream infections related to interventional radiology placement of central venous catheters. A customized web-based clinical database was developed via open-source tools to provide a dashboard for data mining and analysis of the catheter placement and infection information. Preliminary results were gathered over a 4-month period confirming the utility of the system. The tools and methodology employed to develop the vascular access tracking system could be easily tailored to other clinical scenarios to assist in quality control and improvement programs.

  19. Use of a Supraglottic Airway to Relieve Ventilation-Impeding Gastric Insufflation During Emergency Airway Management in an Infant.

    PubMed

    Dodd, Kenneth W; Strobel, Ashley M; Driver, Brian E; Reardon, Robert F

    2016-10-01

    Positive-pressure bag-valve-mask ventilation during emergency airway management often results in significant gastric insufflation, which may impede adequate ventilation and oxygenation. Current-generation supraglottic airways have beneficial features, such as channels for gastric decompression while ventilation is ongoing. A 5-week-old female infant required resuscitation for hypoxemic respiratory failure caused by rhinovirus with pneumonia. Bag-valve-mask ventilation led to gastric insufflation that compromised ventilation, thereby interfering with intubation because of precipitous oxygen desaturation during laryngoscopy. A current-generation supraglottic airway (LMA Supreme; Teleflex Inc, Morrisville, NC) was used to facilitate gastric decompression while ventilation and oxygenation was ongoing. After gastric decompression, ventilation was markedly improved and the pulse oxygen saturation improved to 100%. Intubation was successful on the next attempt, without oxygen desaturation. Current-generation supraglottic airways have 3 distinct advantages compared with first-generation supraglottic airways, which make them better devices for emergency airway management: gastric decompression ports, conduits for intubation, and higher oropharyngeal leak pressures. Copyright © 2016 American College of Emergency Physicians. Published by Elsevier Inc. All rights reserved.

  20. Baicalein Reduces Airway Injury in Allergen and IL-13 Induced Airway Inflammation

    PubMed Central

    Mabalirajan, Ulaganathan; Ahmad, Tanveer; Rehman, Rakhshinda; Leishangthem, Geeta Devi; Dinda, Amit Kumar; Agrawal, Anurag; Ghosh, Balaram; Sharma, Surendra Kumar

    2013-01-01

    Background Baicalein, a bioflavone present in the dry roots of Scutellaria baicalensis Georgi, is known to reduce eotaxin production in human fibroblasts. However, there are no reports of its anti-asthma activity or its effect on airway injury. Methodology/Principal Findings In a standard experimental asthma model, male Balb/c mice that were sensitized with ovalbumin (OVA), treated with baicalein (10 mg/kg, ip) or a vehicle control, either during (preventive use) or after OVA challenge (therapeutic use). In an alternate model, baicalein was administered to male Balb/c mice which were given either IL-4 or IL-13 intranasally. Features of asthma were determined by estimating airway hyperresponsiveness (AHR), histopathological changes and biochemical assays of key inflammatory molecules. Airway injury was determined with apoptotic assays, transmission electron microscopy and assessing key mitochondrial functions. Baicalein treatment reduced AHR and inflammation in both experimental models. TGF-β1, sub-epithelial fibrosis and goblet cell metaplasia, were also reduced. Furthermore, baicalein treatment significantly reduced 12/15-LOX activity, features of mitochondrial dysfunctions, and apoptosis of bronchial epithelia. Conclusion/Significance Our findings demonstrate that baicalein can attenuate important features of asthma, possibly through the reduction of airway injury and restoration of mitochondrial function. PMID:23646158

  1. Hemodialysis Catheter Heat Transfer for Biofilm Prevention and Treatment.

    PubMed

    Richardson, Ian P; Sturtevant, Rachael; Heung, Michael; Solomon, Michael J; Younger, John G; VanEpps, J Scott

    2016-01-01

    Central line-associated bloodstream infections (CLABSIs) are not easily treated, and many catheters (e.g., hemodialysis catheters) are not easily replaced. Biofilms (the source of infection) on catheter surfaces are notoriously difficult to eradicate. We have recently demonstrated that modest elevations of temperature lead to increased staphylococcal susceptibility to vancomycin and significantly soften the biofilm matrix. In this study, using a combination of microbiological, computational, and experimental studies, we demonstrate the efficacy, feasibility, and safety of using heat as an adjuvant treatment for infected hemodialysis catheters. Specifically, we show that treating with heat in the presence of antibiotics led to additive killing of Staphylococcus epidermidis with similar trends seen for Staphylococcus aureus and Klebsiella pneumoniae. The magnitude of temperature elevation required is relatively modest (45-50°C) and similar to that used as an adjuvant to traditional cancer therapy. Using a custom-designed benchtop model of a hemodialysis catheter, positioned with tip in the human vena cava as well as computational fluid dynamic simulations, we demonstrate that these temperature elevations are likely achievable in situ with minimal increased in overall blood temperature.

  2. Infection and natural history of emergency department-placed central venous catheters.

    PubMed

    LeMaster, Christopher H; Schuur, Jeremiah D; Pandya, Darshan; Pallin, Daniel J; Silvia, Jennifer; Yokoe, Deborah; Agrawal, Ashish; Hou, Peter C

    2010-11-01

    Central line-associated bloodstream infection (CLABSI, hereafter referred to in this paper as "bloodstream infection") is a leading cause of hospital-acquired infection. To our knowledge, there are no previously published studies designed to determine the rate of bloodstream infection among central venous catheters placed in the emergency department (ED). We design a retrospective chart review methodology to determine bloodstream infection and duration of catheterization for central venous catheters placed in the ED. Using hospital infection control, administrative, and ED billing databases, we identified patients with central venous catheters placed in the ED between January 1, 2007, and December 31, 2008, at one academic, urban ED with an annual census of 57,000. We performed a structured, explicit chart review to determine duration of catheterization and confirm bloodstream infection. We screened 4,251 charts and identified 656 patients with central venous catheters inserted in the ED, 3,622 catheter-days, and 7 bloodstream infections. The rate of bloodstream infection associated with central venous catheters placed in the ED was 1.93 per 1,000 catheter-days (95% confidence interval 0.50 to 3.36). The mean duration of catheterization was 5.5 days (median 4; range 1 to 29 days). Among infected central venous catheters, the mean duration of catheterization was 8.6 days (median 7; range 2 to 19 days). A total of 667 central venous catheters were placed in the internal jugular (392; 59%), subclavian (145; 22%), and femoral (130; 19%) veins. The sensitivity of using ED procedural billing code for identifying ED-placed central venous catheters among patients subsequently admitted to any ICU was 74.9% (95% confidence interval 71.4% to 78.3%). The rate of ED bloodstream infection at our institution is similar to current rates in ICUs. Central venous catheters placed in the ED remain in admitted patients for a substantial period. Copyright © 2010 American College of

  3. 21 CFR 870.1350 - Catheter balloon repair kit.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Catheter balloon repair kit. 870.1350 Section 870.1350 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1350 Catheter balloon...

  4. 21 CFR 870.2870 - Catheter tip pressure transducer.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Catheter tip pressure transducer. 870.2870 Section 870.2870 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Monitoring Devices § 870.2870 Catheter tip...

  5. 21 CFR 870.1350 - Catheter balloon repair kit.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Catheter balloon repair kit. 870.1350 Section 870.1350 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1350 Catheter balloon...

  6. [Persistent neonatal hypoglycaemia caused by arterial positioning of the umbilical venous catheter].

    PubMed

    Peters, P A G; Brus, F; Noordam, C; Smorenburg, M K; van Setten, P A

    2007-10-06

    Two neonates, a girl born at 40 2/7 weeks weighing 4165 g and a boy born at 37 6/7 weeks weighing 4040 g, received umbilical venous catheters to help manage hypoglycaemia. The catheter was ineffective or only effective when high doses of glucose were used, due to what later appeared to be arterial positioning of the catheter. Both patients recovered without consequences. Persistent hypoglycaemia is a common problem in newborns and can cause severe neurological sequelae. A relatively uncommon cause is malpositioning of the umbilical catheter. Positioning in an artery leads to direct infusion of glucose into the pancreas, which causes hyperinsulinaemia and can lead to potentially dangerous nonketotic hypoglycaemia. Arterial positioning of the umbilical catheter should be ruled out at an early stage. Correct catheter positioning can be determined using careful inspection of the umbilical veins, radiological examination of the catheter position, blood gas analysis or vascular pulsation.

  7. Patient-specific catheter shaping for the minimally invasive closure of the left atrial appendage.

    PubMed

    Graf, Eva C; Ott, Ilka; Praceus, Julian; Bourier, Felix; Lueth, Tim C

    2018-06-01

    The minimally invasive closure of the left atrial appendage is a promising alternative to anticoagulation for stroke prevention in patients suffering from atrial fibrillation. One of the challenges of this procedure is the correct positioning and the coaxial alignment of the tip of the catheter sheath to the implant landing zone. In this paper, a novel preoperative planning system is proposed that allows patient-individual shaping of catheters to facilitate the correct positioning of the catheter sheath by offering a patient-specific catheter shape. Based on preoperative three-dimensional image data, anatomical points and the planned implant position are marked interactively and a patient-specific catheter shape is calculated if the standard catheter is not considered as suitable. An approach to calculate a catheter shape with four bends by maximization of the bending radii is presented. Shaping of the catheter is supported by a bending form that is automatically generated in the planning program and can be directly manufactured by using additive manufacturing methods. The feasibility of the planning and shaping of the catheter could be successfully shown using six data sets. The patient-specific catheters were tested in comparison with standard catheters by physicians on heart models. In four of the six tested models, the participating physicians rated the patient-individual catheters better than the standard catheter. The novel approach for preoperatively planned and shaped patient-specific catheters designed for the minimally invasive closure of the left atrial appendage could be successfully implemented and a feasibility test showed promising results in anatomies that are difficult to access with the standard catheter.

  8. Antigen challenge induces pulmonary airway eosinophil accumulation and airway hyperreactivity in sensitized guinea-pigs: the effect of anti-asthma drugs.

    PubMed Central

    Sanjar, S.; Aoki, S.; Kristersson, A.; Smith, D.; Morley, J.

    1990-01-01

    1. Guinea-pigs were sensitized with 3 injections of ovalbumin (OA) (1 or 10 micrograms per animal) using Al(OH)3 and pertussis vaccine as adjuvants at two week intervals. 2. Sensitized guinea-pigs were challenged with an aerosol of OA (0.1%) over a one hour period and both airway reactivity and cellular content of bronchoalveolar lavage (BAL) fluid were assessed at intervals for up to 7 days. 3. Guinea-pigs sensitized with 1 microgram of ovalbumin responded to an aerosol of OA with increased pulmonary airway eosinophilia, which was evident 1 day after challenge and was present for up to 7 days. Airway hyperreactivity was not detectable in these animals. 4. Guinea-pigs sensitized with 10 micrograms of ovalbumin responded to an aerosol of OA with increased pulmonary airway neutrophilia and eosinophilia and with increased airway reactivity which was maximal between 8 and 24 h after exposure to OA. 5. Depletion of circulating platelets or neutrophils, by use of selective antisera, did not alter either the magnitude of eosinophilia or the intensity of airway reactivity in sensitized guinea-pigs (10 micrograms) exposed to an aerosol of OA. 6. Pretreatment of sensitized guinea-pigs (10 micrograms) for 6 days with AH 21-132, aminophylline, dexamethasone or ketotifen inhibited pulmonary airway eosinophilia, but did not diminish airway hyperreactivity. Neither eosinophil accumulation nor development of airway hyperreactivity was influenced by treatment with mepyramine or salbutamol over a 6 day period before OA inhalation. 7. Although eosinophilia may occur in association with increased airway reactivity in this animal model, there is no evidence of a causal relationship. PMID:2361168

  9. Development of a force-reflecting robotic platform for cardiac catheter navigation.

    PubMed

    Park, Jun Woo; Choi, Jaesoon; Pak, Hui-Nam; Song, Seung Joon; Lee, Jung Chan; Park, Yongdoo; Shin, Seung Min; Sun, Kyung

    2010-11-01

    Electrophysiological catheters are used for both diagnostics and clinical intervention. To facilitate more accurate and precise catheter navigation, robotic cardiac catheter navigation systems have been developed and commercialized. The authors have developed a novel force-reflecting robotic catheter navigation system. The system is a network-based master-slave configuration having a 3-degree of freedom robotic manipulator for operation with a conventional cardiac ablation catheter. The master manipulator implements a haptic user interface device with force feedback using a force or torque signal either measured with a sensor or estimated from the motor current signal in the slave manipulator. The slave manipulator is a robotic motion control platform on which the cardiac ablation catheter is mounted. The catheter motions-forward and backward movements, rolling, and catheter tip bending-are controlled by electromechanical actuators located in the slave manipulator. The control software runs on a real-time operating system-based workstation and implements the master/slave motion synchronization control of the robot system. The master/slave motion synchronization response was assessed with step, sinusoidal, and arbitrarily varying motion commands, and showed satisfactory performance with insignificant steady-state motion error. The current system successfully implemented the motion control function and will undergo safety and performance evaluation by means of animal experiments. Further studies on the force feedback control algorithm and on an active motion catheter with an embedded actuation mechanism are underway. © 2010, Copyright the Authors. Artificial Organs © 2010, International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  10. Complications Related to Insertion and Use of Central Venous Catheters (CVC).

    PubMed

    Hodzic, Samir; Golic, Darko; Smajic, Jasmina; Sijercic, Selma; Umihanic, Sekib; Umihanic, Sefika

    2014-10-01

    Central Venous Catheters (CVC) are essential in everyday medical practice, especially in treating patients in intensive care units (ICU). The application of these catheters is accompanied with the risk of complications, such as the complications caused during the CVC insertion, infections at the location of the insertion, and complications during the use of the catheter, sepsis and other metastatic infections. This study is a retrospective-prospective and it was implemented in the period 1(st) January 2011- 31(st) December 2012. It included 108 examinees with CVC placed for more than 7 days. The most common complications occurring in more than 2 attempts of CVC applications are: hearth arrhythmias in both groups in 12 cases, 7 in multi-lumen (12.72%) and 5 in mono-lumen ones (9.43%). Artery puncture occurs in both groups in 7 cases, 5 in multi-lumen (9.09%) and 2 in mono-lumen ones (3.77%). Hematoma occurred in both groups in 4 cases, 3 in multi-lumen CVCs (5.45%) and 1 in mono-lumen ones (1.88%). The most common complication in multi-lumen catheters was heart arrhythmia, in 20 cases (36.37%). The most common complications in mono-lumen CVCs was hearth arrhythmias, in 20 cases as extrasystoles and they were registered in 16 catheter insertions (30.18%). Out of total number of catheters of both groups, out of 108 catheters the complications during insertion occurred in 49 catheters (45.40%). The most common complications in both groups were heart arrhythmias, artery punctures and hematomas at the place of catheter insertion.

  11. Catheter tracking using continuous radial MRI.

    PubMed

    Rasche, V; Holz, D; Köhler, J; Proksa, R; Röschmann, P

    1997-06-01

    The guidance of minimally invasive procedures may become a very important future application of MRI. The guidance of interventions requires images of the anatomy as well as the information of the position of invasive devices used. This paper introduces continuous radial MRI for the simultaneous acquisition of the anatomic MR image and the position of one or more small RF-coils (mu-coils), which can be mounted on invasive devices such as catheters or biopsy needles. This approach allows the in-plane tracking of an invasive device without any prolongation of the overall acquisition time. The extension to three-dimensional position tracking is described. Phantom studies are presented demonstrating the capability of this technique for real-time automatic adjustment of the slice position to the current catheter position with a temporal resolution of 100 ms. Simultaneously the in-plane catheter position is depicted in the actually acquired MR image during continuous scanning.

  12. Permcath Catheter Embolization: a Case Report

    PubMed Central

    Yousefshahi, Hadi; Bina, Payvand; Yousefshahi, Fardin

    2015-01-01

    Introduction: Nowadays, many types of intravascular devices and catheters are used in order to diagnose and treat diseases. Complications related to these instruments are the costs that doctors and patients have to pay to benefit from their advantages. Catheter embolization is one of these side effects. Patients with devices in their cardiopulmonary system are at risk for severe complications such as arrhythmias, pulmonary embolism, myocardial injuries, hemoptysis, thrombosis and perforation. Case Presentation: A 50-years-old woman, with a history of breast cancer, had a PermCath emplacement in right subclavian vein for a course of chemotherapy. The treatment for cancer seemed to be successful and the PermCath had remained in its position without complication, for a couple of years however, the catheter was founded broken and embolized to the right ventricle and the main left pulmonary artery, diagnosed by a chest X-ray study incidentally. Conclusions: It is better to remove the unused devices safely to prevent and decrease their possible complications. PMID:25964881

  13. Permcath catheter embolization: a case report.

    PubMed

    Yousefshahi, Hadi; Bina, Payvand; Yousefshahi, Fardin

    2015-04-01

    Nowadays, many types of intravascular devices and catheters are used in order to diagnose and treat diseases. Complications related to these instruments are the costs that doctors and patients have to pay to benefit from their advantages. Catheter embolization is one of these side effects. Patients with devices in their cardiopulmonary system are at risk for severe complications such as arrhythmias, pulmonary embolism, myocardial injuries, hemoptysis, thrombosis and perforation. A 50-years-old woman, with a history of breast cancer, had a PermCath emplacement in right subclavian vein for a course of chemotherapy. The treatment for cancer seemed to be successful and the PermCath had remained in its position without complication, for a couple of years however, the catheter was founded broken and embolized to the right ventricle and the main left pulmonary artery, diagnosed by a chest X-ray study incidentally. It is better to remove the unused devices safely to prevent and decrease their possible complications.

  14. Performance evaluation of a robot-assisted catheter operating system with haptic feedback.

    PubMed

    Song, Yu; Guo, Shuxiang; Yin, Xuanchun; Zhang, Linshuai; Hirata, Hideyuki; Ishihara, Hidenori; Tamiya, Takashi

    2018-06-20

    In this paper, a novel robot-assisted catheter operating system (RCOS) has been proposed as a method to reduce physical stress and X-ray exposure time to physicians during endovascular procedures. The unique design of this system allows the physician to apply conventional bedside catheterization skills (advance, retreat and rotate) to an input catheter, which is placed at the master side to control another patient catheter placed at the slave side. For this purpose, a magnetorheological (MR) fluids-based master haptic interface has been developed to measure the axial and radial motions of an input catheter, as well as to provide the haptic feedback to the physician during the operation. In order to achieve a quick response of the haptic force in the master haptic interface, a hall sensor-based closed-loop control strategy is employed. In slave side, a catheter manipulator is presented to deliver the patient catheter, according to position commands received from the master haptic interface. The contact forces between the patient catheter and blood vessel system can be measured by designed force sensor unit of catheter manipulator. Four levels of haptic force are provided to make the operator aware of the resistance encountered by the patient catheter during the insertion procedure. The catheter manipulator was evaluated for precision positioning. The time lag from the sensed motion to replicated motion is tested. To verify the efficacy of the proposed haptic feedback method, the evaluation experiments in vitro are carried out. The results demonstrate that the proposed system has the ability to enable decreasing the contact forces between the catheter and vasculature.

  15. [Yeast colonization of urinary catheters and the significance of biofilm formation].

    PubMed

    Růžička, Filip; Holá, Veronika; Mahelová, Martina; Procházková, Alena

    2012-08-01

    Urinary catheters are colonized by a wide range of microorganisms, including numerous yeasts. The catheters are usually colonized by more microbial species forming a community - multispecies biofilm. Catheter colonization usually does not affect the patient's clinical status in any significant way. On the other hand, the biofilm can become a source of endogenous infection and its presence can affect functionality of the catheter and formation of urinary stones. Material a A total of 721 urinary catheters were studied. Microorganisms were released from catheters by sonication and subsequently cultured. Their identification was performed with the use of common phenotypic tests, as well as using MALDI TOF. Yeasts whose identification was ambiguous were recognized by sequencing. Biofilm formation was assessed by growth in a microtiter plate. Yeast colonization was proved in 244 urinary catheters. However, a total of 274 yeast strains were isolated. Most of them occurred together with other yeast species and/or bacteria on the catheters, producing multispecies biofilm there. The most frequent species was Candida albicans (a total of 144 isolated strains), followed by Candida glabrata (41), Candida tropicalis (41) and Candida parapsilosis sensu stricto (14). Other isolated species were as follows: Candida kefyr (10), Candida krusei (9), Candida fabianii (6), Candida lusitaniae (5), Candida dubliniensis (3) and Saccharomyces cerevisiae (one case). Most of the yeasts rather readily formed a firmly adhering biofilm layer on artificial surfaces.

  16. [Upper airway morphology in Down Syndrome patients under dexmedetomidine sedation].

    PubMed

    Subramanyam, Rajeev; Fleck, Robert; McAuliffe, John; Radhakrishnan, Rupa; Jung, Dorothy; Patino, Mario; Mahmoud, Mohamed

    2016-01-01

    Children with Down Syndrome are vulnerable to significant upper airway obstruction due to relative macroglossia and dynamic airway collapse. The objective of this study was to compare the upper airway dimensions of children with Down Syndrome and obstructive sleep apnea with normal airway under dexmedetomidine sedation. IRB approval was obtained. In this retrospective study, clinically indicated dynamic sagittal midline magnetic resonance images of the upper airway were obtained under low (1mcg/kg/h) and high (3mcg/kg/h) dose dexmedetomidine. Airway anteroposterior diameters and sectional areas were measured as minimum and maximum dimensions by two independent observers at soft palate (nasopharyngeal airway) and at base of the tongue (retroglossal airway). Minimum anteroposterior diameter and minimum sectional area at nasopharynx and retroglossal airway were significantly reduced in Down Syndrome compared to normal airway at both low and high dose dexmedetomidine. However, there were no significant differences between low and high dose dexmedetomidine in both Down Syndrome and normal airway. The mean apnea hypopnea index in Down Syndrome was 16±11. Under dexmedetomidine sedation, children with Down Syndrome and obstructive sleep apnea when compared to normal airway children show significant reductions in airway dimensions most pronounced at the narrowest points in the nasopharyngeal and retroglossal airways. Copyright © 2015 Sociedade Brasileira de Anestesiologia. Publicado por Elsevier Editora Ltda. All rights reserved.

  17. Upper airway morphology in Down Syndrome patients under dexmedetomidine sedation.

    PubMed

    Subramanyam, Rajeev; Fleck, Robert; McAuliffe, John; Radhakrishnan, Rupa; Jung, Dorothy; Patino, Mario; Mahmoud, Mohamed

    2016-01-01

    Children with Down Syndrome are vulnerable to significant upper airway obstruction due to relative macroglossia and dynamic airway collapse. The objective of this study was to compare the upper airway dimensions of children with Down Syndrome and obstructive sleep apnea with normal airway under dexmedetomidine sedation. IRB approval was obtained. In this retrospective study, clinically indicated dynamic sagittal midline magnetic resonance images of the upper airway were obtained under low (1mcg/kg/h) and high (3mcg/kg/h) dose dexmedetomidine. Airway anteroposterior diameters and sectional areas were measured as minimum and maximum dimensions by two independent observers at soft palate (nasopharyngeal airway) and at base of the tongue (retroglossal airway). Minimum anteroposterior diameter and minimum sectional area at nasopharynx and retroglossal airway were significantly reduced in Down Syndrome compared to normal airway at both low and high dose dexmedetomidine. However, there were no significant differences between low and high dose dexmedetomidine in both Down Syndrome and normal airway. The mean apnea hypopnea index in Down Syndrome was 16±11. Under dexmedetomidine sedation, children with Down Syndrome and obstructive sleep apnea when compared to normal airway children show significant reductions in airway dimensions most pronounced at the narrowest points in the nasopharyngeal and retroglossal airways. Copyright © 2015 Sociedade Brasileira de Anestesiologia. Published by Elsevier Editora Ltda. All rights reserved.

  18. Heating and Cooling Rates With an Esophageal Heat Exchange System.

    PubMed

    Kalasbail, Prathima; Makarova, Natalya; Garrett, Frank; Sessler, Daniel I

    2018-04-01

    The Esophageal Cooling Device circulates warm or cool water through an esophageal heat exchanger, but warming and cooling efficacy in patients remains unknown. We therefore determined heat exchange rates during warming and cooling. Nineteen patients completed the trial. All had general endotracheal anesthesia for nonthoracic surgery. Intraoperative heat transfer was measured during cooling (exchanger fluid at 7°C) and warming (fluid at 42°C). Each was evaluated for 30 minutes, with the initial condition determined randomly, starting at least 40 minutes after induction of anesthesia. Heat transfer rate was estimated from fluid flow through the esophageal heat exchanger and inflow and outflow temperatures. Core temperature was estimated from a zero-heat-flux thermometer positioned on the forehead. Mean heat transfer rate during warming was 18 (95% confidence interval, 16-20) W, which increased core temperature at a rate of 0.5°C/h ± 0.6°C/h (mean ± standard deviation). During cooling, mean heat transfer rate was -53 (-59 to -48) W, which decreased core temperature at a rate of 0.9°C/h ± 0.9°C/h. Esophageal warming transferred 18 W which is considerably less than the 80 W reported with lower or upper body forced-air covers. However, esophageal warming can be used to supplement surface warming or provide warming in cases not amenable to surface warming. Esophageal cooling transferred more than twice as much heat as warming, consequent to the much larger difference between core and circulating fluid temperature with cooling (29°C) than warming (6°C). Esophageal cooling extracts less heat than endovascular catheters but can be used to supplement catheter-based cooling or possibly replace them in appropriate patients.

  19. Cost-Effectiveness of a Central Venous Catheter Care Bundle

    PubMed Central

    Halton, Kate A.; Cook, David; Paterson, David L.; Safdar, Nasia; Graves, Nicholas

    2010-01-01

    Background A bundled approach to central venous catheter care is currently being promoted as an effective way of preventing catheter-related bloodstream infection (CR-BSI). Consumables used in the bundled approach are relatively inexpensive which may lead to the conclusion that the bundle is cost-effective. However, this fails to consider the nontrivial costs of the monitoring and education activities required to implement the bundle, or that alternative strategies are available to prevent CR-BSI. We evaluated the cost-effectiveness of a bundle to prevent CR-BSI in Australian intensive care patients. Methods and Findings A Markov decision model was used to evaluate the cost-effectiveness of the bundle relative to remaining with current practice (a non-bundled approach to catheter care and uncoated catheters), or use of antimicrobial catheters. We assumed the bundle reduced relative risk of CR-BSI to 0.34. Given uncertainty about the cost of the bundle, threshold analyses were used to determine the maximum cost at which the bundle remained cost-effective relative to the other approaches to infection control. Sensitivity analyses explored how this threshold alters under different assumptions about the economic value placed on bed-days and health benefits gained by preventing infection. If clinicians are prepared to use antimicrobial catheters, the bundle is cost-effective if national 18-month implementation costs are below $1.1 million. If antimicrobial catheters are not an option the bundle must cost less than $4.3 million. If decision makers are only interested in obtaining cash-savings for the unit, and place no economic value on either the bed-days or the health benefits gained through preventing infection, these cost thresholds are reduced by two-thirds. Conclusions A catheter care bundle has the potential to be cost-effective in the Australian intensive care setting. Rather than anticipating cash-savings from this intervention, decision makers must be prepared

  20. Cost-effectiveness of a central venous catheter care bundle.

    PubMed

    Halton, Kate A; Cook, David; Paterson, David L; Safdar, Nasia; Graves, Nicholas

    2010-09-17

    A bundled approach to central venous catheter care is currently being promoted as an effective way of preventing catheter-related bloodstream infection (CR-BSI). Consumables used in the bundled approach are relatively inexpensive which may lead to the conclusion that the bundle is cost-effective. However, this fails to consider the nontrivial costs of the monitoring and education activities required to implement the bundle, or that alternative strategies are available to prevent CR-BSI. We evaluated the cost-effectiveness of a bundle to prevent CR-BSI in Australian intensive care patients. A Markov decision model was used to evaluate the cost-effectiveness of the bundle relative to remaining with current practice (a non-bundled approach to catheter care and uncoated catheters), or use of antimicrobial catheters. We assumed the bundle reduced relative risk of CR-BSI to 0.34. Given uncertainty about the cost of the bundle, threshold analyses were used to determine the maximum cost at which the bundle remained cost-effective relative to the other approaches to infection control. Sensitivity analyses explored how this threshold alters under different assumptions about the economic value placed on bed-days and health benefits gained by preventing infection. If clinicians are prepared to use antimicrobial catheters, the bundle is cost-effective if national 18-month implementation costs are below $1.1 million. If antimicrobial catheters are not an option the bundle must cost less than $4.3 million. If decision makers are only interested in obtaining cash-savings for the unit, and place no economic value on either the bed-days or the health benefits gained through preventing infection, these cost thresholds are reduced by two-thirds. A catheter care bundle has the potential to be cost-effective in the Australian intensive care setting. Rather than anticipating cash-savings from this intervention, decision makers must be prepared to invest resources in infection control to

  1. 21 CFR 870.2870 - Catheter tip pressure transducer.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... change in relation to changes in blood pressure. These changes are transmitted to accessory equipment for... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Catheter tip pressure transducer. 870.2870 Section... pressure transducer. (a) Identification. A catheter tip pressure transducer is a device incorporated into...

  2. 21 CFR 870.2870 - Catheter tip pressure transducer.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... change in relation to changes in blood pressure. These changes are transmitted to accessory equipment for... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Catheter tip pressure transducer. 870.2870 Section... pressure transducer. (a) Identification. A catheter tip pressure transducer is a device incorporated into...

  3. 21 CFR 870.2870 - Catheter tip pressure transducer.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... change in relation to changes in blood pressure. These changes are transmitted to accessory equipment for... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Catheter tip pressure transducer. 870.2870 Section... pressure transducer. (a) Identification. A catheter tip pressure transducer is a device incorporated into...

  4. 21 CFR 870.2870 - Catheter tip pressure transducer.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... change in relation to changes in blood pressure. These changes are transmitted to accessory equipment for... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Catheter tip pressure transducer. 870.2870 Section... pressure transducer. (a) Identification. A catheter tip pressure transducer is a device incorporated into...

  5. The Tulip GT® airway versus the facemask and Guedel airway: a randomised, controlled, cross-over study by Basic Life Support-trained airway providers in anaesthetised patients.

    PubMed

    Shaikh, A; Robinson, P N; Hasan, M

    2016-03-01

    We performed a randomised, controlled, cross-over study of lung ventilation by Basic Life Support-trained providers using either the Tulip GT® airway or a facemask with a Guedel airway in 60 anaesthetised patients. Successful ventilation was achieved if the provider produced an end-tidal CO2 > 3.5 kPa and a tidal volume > 250 ml in two of the first three breaths, within 60 sec and within two attempts. Fifty-seven (95%) providers achieved successful ventilation using the Tulip GT compared with 35 (58%) using the facemask (p < 0.0001). Comparing the Tulip GT and facemask, the mean (SD) end-tidal CO2 was 5.0 (0.7) kPa vs 2.5 (1.5) kPa, tidal volume was 494 (175) ml vs 286 (186) ml and peak inspiratory pressure was 18.3 (3.4) cmH2 O vs 13.6 (7) cmH2 O respectively (all p < 0.0001). Forty-seven (78%) users favoured the Tulip GT airway. These results are similar to a previous manikin study using the same protocol, suggesting a close correlation between human and manikin studies for this airway device. We conclude that the Tulip GT should be considered as an adjunct to airway management both within and outside hospitals when ventilation is being undertaken by Basic Life Support-trained airway providers. © 2015 The Association of Anaesthetists of Great Britain and Ireland.

  6. Use of laparoscopy in the management of malfunctioning peritoneal dialysis catheters.

    PubMed

    Brandt, C P; Ricanati, E S

    1996-01-01

    The proper function of peritoneal dialysis (PD) catheters can be compromised by catheter malposition, fibrin clot, or omental wrapping. The purpose of this study was to determine the efficacy of laparoscopy in the treatment of malfunctioning PD catheters. All patients undergoing laparoscopy for catheter dysfunction at MetroHealth Medical Center in Cleveland, Ohio, from 1991 to 1995, were reviewed. Twenty-six laparoscopies were performed in 22 patients, for malfunction occurring an average of 3.9 months following insertion (range 0.5-18 months). Omental and/or small below wrapping as present in all but three cases. Lysis of adhesions was required in 19 of 26 cases, with repositioning only in seven. Eight patients had failed attempts at stiff wire manipulation prior to laparoscopy. Perioperative complications occurred in seven cases, consisting of temporary dialysate leakage (2), enterotomy (1), and early reocclusion (4). Repeat laparoscopy was successful in three of these four reocclusions. The overall success rate (catheter function > 30 days after laparoscopy) was 21/22 (96%). Laparoscopy is highly accurate and effective in the management of peritoneal dialysis catheter dysfunction and results in prolongation of catheter life.

  7. Endovascular recanalization of a port catheter-associated superior vena cava syndrome.

    PubMed

    Tonak, Julia; Fetscher, Sebastian; Barkhausen, Jörg; Goltz, Jan Peter

    2015-01-01

    Superior vena cava (SVC) syndrome owing to benign etiology is rare and endovascular techniques have been advocated as the treatment of choice. We report a case of endovascular revascularization of a port catheter-associated complete occlusion of the SVC with reversed flow in the azygos vein. In this setting using a sheath in combination with its dilatator to pass the occlusion of the SVC after neither a diagnostic catheter nor a PTA balloon would pass the lesion may be a valid option. A dual venous approach was established using the right common femoral vein and an indwelling port catheter in the right cephalic vein to dilate and stent the lesion. Finally, a port may be implanted after the revascularization had been successful. Passage through the port catheter-associated occlusion of the SVC was only possible by use of the sheath in combination with its dilatator. A dual venous access by the femoral approach and the indwelling central catheter is helpful in treating a SVC occlusion. Long-term central venous catheters may cause SVC syndrome, especially with a catheter tip located too far cranially. An endovascular revascularization of a complete occlusion of the SVC represents the therapy of choice.

  8. Femoral venous access is safe in burned children: an analysis of 224 catheters.

    PubMed

    Goldstein, A M; Weber, J M; Sheridan, R L

    1997-03-01

    To document the incidence of septic and mechanical complications associated with femoral venous catheters in a subgroup of patients thought to be at particularly high risk of both: young children with large burns. An analysis of data collected prospectively on all femoral venous catheters placed during a 4-year period at a regional pediatric burn facility. There were 224 femoral catheters placed in 86 children with an average age of 5.3 +/- 5.1 years and an average burn size of 38% +/- 23%. Catheters were left in place for a mean duration of 5.7 days. Catheter-related sepsis occurred with 4.9% of the catheters, and mechanical complications occurred in 3.5% of the patients. There was no statistically significant association between the risk of catheter sepsis and the placement of catheters through burned versus unburned skin. Similarly, the risk of sepsis was equivalent between lines placed over a guide wire and those placed of a new site. Femoral venous catheters are safe in burned children and are associated with a low incidence of infectious and mechanical complications.

  9. Guide Catheter Extension Device Is Effective in Renal Angioplasty for Severely Calcified Lesions.

    PubMed

    Sugimoto, Takeshi; Nomura, Tetsuya; Hori, Yusuke; Yoshioka, Kenichi; Kubota, Hiroshi; Miyawaki, Daisuke; Urata, Ryota; Kikai, Masakazu; Keira, Natsuya; Tatsumi, Tetsuya

    2017-05-23

    BACKGROUND The GuideLiner catheter extension device is a monorail-type "Child" support catheter that facilitates coaxial alignment with the guide catheter and provides an appropriate back-up force. This device has been developed in the field of coronary intervention, and now is becoming widely applied in the field of endovascular treatment. However, there has been no report on the effectiveness of the guide catheter extension device in percutaneous transluminal renal angioplasty (PTRA). CASE REPORT We encountered a case of atherosclerotic subtotal occlusion at the ostium of the left renal artery. Due to the severely calcified orifice and weaker back-up force provided by a JR4 guide catheter, we could not pass any guidewires through the target lesion. Therefore, we introduced a guide catheter extension device, the GuideLiner catheter, through the guide catheter and achieved good guidewire maneuverability. We finally deployed 2 balloon-expandable stents and successfully performed all PTRA procedures. CONCLUSIONS The guide catheter extension device can be effective in PTRA for severely calcified subtotal occlusion.

  10. A prospective randomized trial of the LoFric hydrophilic coated catheter versus conventional plastic catheter for clean intermittent catheterization.

    PubMed

    Vapnek, Jonathan M; Maynard, Frederick M; Kim, Jiensup

    2003-03-01

    We compared the incidence of hematuria, pyuria and clinical urinary tract infection in patients who performed intermittent self-catheterization using a hydrophilic coated LoFric (Astra Tech AB, Mölndal, Sweden) or standard plastic catheter. A total of 62 male patients who performed intermittent self-catheterization to manage neurogenic bladder were randomized into 2 treatment groups at 3 American study sites. Outcome measures included urinary tract infection, microhematuria, pyuria and satisfaction rates. Of the 62 enrolled patients 49 completed the 12-month study. The withdrawal rate was not different in the 2 groups. At the end of the study there was statistically significantly less hematuria in the hydrophilic coated catheter group compared with controls. In addition, there was a significant decrease in the urinary tract infection rate from baseline in the hydrophilic coated catheter group but not in controls. Use of the hydrophilic coated catheter by patients on intermittent self-catheterization is associated with less hematuria and a significant decrease in the incidence of urinary tract infections. Therefore, it may be preferable for some patients, especially those with a history of difficult catheterization, urethral trauma or a high rate of urinary tract infection.

  11. Catheter use and infection reduction in plastic surgery

    PubMed Central

    Barnes, Zach J; Mahabir, Raman C

    2013-01-01

    BACKGROUND: Catheter-associated urinary tract infections (CAUTI) are the most common hospital-associated infection and can result in increased health care costs, morbidity and even mortality. In 2009, The Scott & White Memorial Hospital/Texas A&M Health Science Center (Texas, USA) system’s CAUTI rate placed it in the upper quartile (ie, highest rate) for the country, necessitating a system-wide change. OBJECTIVE: To design and implement a guideline to reduce the incidence of CAUTI. METHODS: A multidisciplinary team was formed and completed both a root cause analysis and a review of the available literature. Consolidating the best evidence, the team formulated a best practice guideline detailing the proper indications for insertion of, improper use of and techniques to minimize infection with catheters. Included as part of this protocol was nursing and patient education, changes in identifying patients with a catheter and automatic termination orders. Three-, six- and 12-month reviews identifying additional opportunities for improvement at the end of 2010 were completed. RESULTS: In 2009, the hospital’s CAUTI rate was 1.46 per 1000 catheter days. In 2011 – the first complete year of the finalized guideline – the hospital’s CAUTI rate was 0.52 per 1000 catheter days, ranking the institution in the bottom quartile (ie, lowest rate) for the country. The surgery and plastic surgery subgroup analyses also demonstrated statistically significant reduction in both catheter use and CAUTI. CONCLUSION: The incidence of CAUTI was successfully reduced at The Texas A&M Healthcare Center. The guideline, its development and how it applies to plastic surgery patients are discussed. PMID:24431946

  12. Intracranial placement of a new, compliant guide catheter: technical note.

    PubMed

    Park, Min S; Stiefel, Michael F; Fiorella, David; Kelly, Michael; McDougall, Cameron G; Albuquerque, Felipe C

    2008-09-01

    We describe our initial experience with the use of a novel, compliant guide catheter designed for placement within the cranial vasculature in a series of seven patients who were treated for various intracranial pathologies. Seven patients were deemed to have either tortuous supra-aortic, intracranial, and/or extracranial vasculature or to require additional microcatheter support as the result of lesion location. The patients were treated, in part, with the 6-French Neuron delivery catheter (Penumbra, Inc., San Leandro, CA) at the authors' two institutions. The guide catheter was positioned in various distal locations within the intracranial internal carotid artery or external carotid artery. Three patients were treated for unruptured intracranial aneurysms, 2 patients for intracranial atherosclerosis, 1 patient for an arteriovenous malformation, and 1 patient for a pseudoaneurysm. All lesions were successfully treated through a microcatheter advanced in a coaxial fashion through the guide catheter. There were no complications related to the positioning of the catheter. Distal intra- or extracranial placement of a specially designed, compliant guide catheter can be performed safely and may improve access and microcatheter stability in patients with tortuous vessels or difficult-to-reach lesions.

  13. Airway obstruction in children with infectious mononucleosis.

    PubMed

    Wohl, D L; Isaacson, J E

    1995-09-01

    Epstein-Barr Virus (EBV) infection generally has a benign clinical course. Upper airway obstruction is a known complication requiring the otolaryngologist's attention. EBV is usually associated with adolescence but has been increasingly documented in younger children. We review 36 pediatric admissions for infectious mononucleosis over a 12-year period at our institution, 11 of which required consultation for airway obstruction. Airway management was based on clinical severity and ranged from monitored observation, with or without nasopharyngeal stenting, to prolonged intubation or emergent tonsilloadenoidectomy. A rare case of a four-year-old with near total upper airway obstruction secondary to panpharyngeal and transglottic inflammatory edema prompted this review and is reported. The otolaryngologist must recognize the potential severity of EBV-related airway compromise and be prepared to manage it.

  14. An Effective Technique for Enhancing an Intrauterine Catheter Fetal Electrocardiogram

    NASA Astrophysics Data System (ADS)

    Horner, Steven L.; Holls, William M.

    2003-12-01

    Physician can obtain fetal heart rate, electrophysiological information, and uterine contraction activity for determining fetal status from an intrauterine catheters electrocardiogram with the maternal electrocardiogram canceled. In addition, the intrauterine catheter would allow physicians to acquire fetal status with one non-invasive to the fetus biosensor as compared to invasive to the fetus scalp electrode and intrauterine pressure catheter used currently. A real-time maternal electrocardiogram cancellation technique of the intrauterine catheters electrocardiogram will be discussed along with an analysis for the methods effectiveness with synthesized and clinical data. The positive results from an original detailed subjective and objective analysis of synthesized and clinical data clearly indicate that the maternal electrocardiogram cancellation method was found to be effective. The resulting intrauterine catheters electrocardiogram from effectively canceling the maternal electrocardiogram could be used for determining fetal heart rate, fetal electrocardiogram electrophysiological information, and uterine contraction activity.

  15. Airway responsiveness to mannitol in asthma is associated with chymase-positive mast cells and eosinophilic airway inflammation.

    PubMed

    Sverrild, A; Bergqvist, A; Baines, K J; Porsbjerg, C; Andersson, C K; Thomsen, S F; Hoffmann, H J; Gibson, P; Erjefält, J S; Backer, V

    2016-02-01

    Airway hyperresponsiveness (AHR) to inhaled mannitol is associated with indirect markers of mast cell activation and eosinophilic airway inflammation. It is unknown how AHR to mannitol relates to mast cell phenotype, mast cell function and measures of eosinophilic inflammation in airway tissue. We compared the number and phenotype of mast cells, mRNA expression of mast cell-associated genes and number of eosinophils in airway tissue of subjects with asthma and healthy controls in relation to AHR to mannitol. Airway hyperresponsiveness to inhaled mannitol was measured in 23 non-smoking, corticosteroid-free asthmatic individuals and 10 healthy controls. Mast cells and eosinophils were identified in mucosal biopsies from all participants. Mast cells were divided into phenotypes based on the presence of chymase. mRNA expression of mast cell-associated genes was measured by real-time PCR. The proportion of submucosal MCTC was higher in asthmatic individuals with AHR to mannitol compared with asthmatic individuals without AHR (median: 40.3% vs. 18.7%, P = 0.03). Increased submucosal MCTC numbers were associated with increased levels of mRNA for thymic stromal lymphopoietin (TSLP) and CPA3 in asthmatics. Reactivity to mannitol correlated significantly with eosinophils in submucosa (r(s): 0.56, P = 0.01). Airway hyperresponsiveness to inhaled mannitol is associated with an altered submucosal mast cell profile in asthmatic individuals. This mast cell profile is associated with increased levels of TSLP and CPA3. The degree of AHR to mannitol is correlated with the degree of eosinophilic inflammation in the airway submucosa. © 2015 John Wiley & Sons Ltd.

  16. 21 CFR 870.4210 - Cardiopulmonary bypass vascular catheter, cannula, or tubing.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Cardiopulmonary bypass vascular catheter, cannula... Devices § 870.4210 Cardiopulmonary bypass vascular catheter, cannula, or tubing. (a) Identification. A cardiopulmonary bypass vascular catheter, cannula, or tubing is a device used in cardiopulmonary surgery to...

  17. 21 CFR 870.4210 - Cardiopulmonary bypass vascular catheter, cannula, or tubing.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Cardiopulmonary bypass vascular catheter, cannula... Devices § 870.4210 Cardiopulmonary bypass vascular catheter, cannula, or tubing. (a) Identification. A cardiopulmonary bypass vascular catheter, cannula, or tubing is a device used in cardiopulmonary surgery to...

  18. 21 CFR 868.2600 - Airway pressure monitor.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Airway pressure monitor. 868.2600 Section 868.2600 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Monitoring Devices § 868.2600 Airway pressure monitor. (a) Identification. An airway pressure monitor is a devic...

  19. A new disposable MEMS-based manometric catheter for in-vivo medical tests

    NASA Astrophysics Data System (ADS)

    Teng, Ming-Foey; Hariz, Alex J.; Hsu, Hung-Yao

    2006-12-01

    In this paper we report on the development of a new disposable manometric catheter for diagnosis of functional swallowing disorders. The function of this catheter is to measure the intrabolus and peak pressures occurring along the esophageal tract during the swallowing process. Traditionally, in hospitals the water perfusion technique is used to diagnose the disorder. Current manometric catheters developed elsewhere use a solid-state pressure sensor mounted directly on a thin catheter to measure the pressure changes. Both types of catheters are re-usable due to the high running cost, and this in turn increases the risk of contamination among patients, and creates hygiene problems. We have developed a new disposable manometric catheter which consists of a MEMS-based pressure sensor. Recent laboratory characterizations and hospital in-vivo tests show the new developed low cost disposable catheter prototype capable of measuring pressure ranges of 0 to 100mmHg. The in-vivo tests have also shown the new catheter prototype capable of measuring the peak pressure as well as the intrabolus pressure which is a very important parameter for doctors to carry out the required diagnosis.

  20. The left atrial catheter: its uses and complications.

    PubMed

    Leitman, B S; Naidich, D P; McGuinness, G; McCauley, D I

    1992-11-01

    The authors describe the radiographic appearance of the left atrial catheter, a widely used postsurgical intracardiac device. Recognition of the characteristic appearance of this catheter should be of value in detection of potential complications, including line fracture with resultant retention and/or embolization, infection, prosthetic valve dysfunction, and even cardiac tamponade.

  1. Early catheter removal after radical retropubic prostatectomy: long-term followup.

    PubMed

    Koch, Michael O; Nayee, Anish H; Sloan, James; Gardner, Thomas; Wahle, Greg R; Bihrle, Richard; Foster, Richard S

    2003-06-01

    We examine the complication and continence rates with early catheter removal (day 3 or 4) after radical retropubic prostatectomy. A total of 365 patients with localized prostate cancer underwent radical retropubic prostatectomy at Indiana University Hospital with planned urethral catheter removal before discharge home. Low pressure cystograms were performed on postoperative day 3 or 4 to determine if catheter removal was possible. A subset of patients were analyzed using a validated prostate cancer specific questionnaire (University of California, Los Angeles Prostate Cancer Symptom Index) to determine quality of life outcomes. The catheter was removed on postoperative day 3 or 4 in 263 patients (72%). The reasons for leaving the catheter indwelling were significant leak on cystogram or excessive suprapubic drainage (21%), extensive bladder neck reconstruction (1%) and prolonged hospitalization because of an ileus or other complicating factor (6%). Thirteen patients (3.6%) were either unable to void after catheter removal or presented with retention (not associated with hematuria or clots) after hospital discharge, requiring reinsertion of the Foley catheter. A total of 41 patients (11%) had either an early or late complication (excluding incontinence). There were 3 complications (0.8%) that were considered major because they were potentially life threatening or required a return to the operating room. A pelvic abscess developed in 2 patients and a lymphocele in 1, which required percutaneous drainage. After at least 6 months (mean 20.9 months) 140 patients (89.2%) and 14 (8.9%) reported excellent and good continence, respectively. The patient questionnaire demonstrated bother scores to be minimal to no bother for 95% to 98% of patients at 6 and 12 months. This study confirms that it is safe to remove catheters in most patients 3 to 4 days after prostatectomy if a cystogram demonstrates no extravasation. Complication rates and continence rates with this approach

  2. Recurrent airway obstructions in a patient with benign tracheal stenosis and a silicone airway stent: a case report

    PubMed Central

    Sriram, KB; Robinson, PC

    2008-01-01

    Airway stents (silicone and metal stents) are used to treat patients with benign tracheal stenosis, who are symptomatic and in whom tracheal surgical reconstruction has failed or is not appropriate. However airway stents are often associated with complications such as migration, granuloma formation and mucous hypersecretion, which cause significant morbidity, especially in patients with benign tracheal stenosis and relatively normal life expectancy. We report a patient who had frequent critical airway obstructions over 8 years due to granuloma and mucus hypersecretion in a silicone airway stent. The problem was resolved when the silicone stent was removed and replaced with a covered self expanding metal stent. PMID:18840299

  3. Nitric oxide charged catheters as a potential strategy for prevention of hospital acquired infections.

    PubMed

    Margel, David; Mizrahi, Mark; Regev-Shoshani, Gili; Ko, Mary; Moshe, Maya; Ozalvo, Rachel; Shavit-Grievink, Liat; Baniel, Jack; Kedar, Daniel; Yossepowitch, Ofer; Lifshitz, David; Nadu, Andrei; Greenberg, David; Av-Gay, Yossef

    2017-01-01

    Catheter-Associated Hospital-Acquired Infections (HAI's) are caused by biofilm-forming bacteria. Using a novel approach, we generated anti-infective barrier on catheters by charging them with Nitric Oxide (NO), a naturally-produced gas molecule. NO is slowly released from the catheter upon contact with physiological fluids, and prevents bacterial colonization and biofilm formation onto catheter surfaces. The aim of the study was to assess the anti-infective properties of NO-charged catheters exposed to low concentration (up to 103 CFU/ml) of microbial cells in-vitro. We assessed NO-charged tracheal tubes using Pseudomonas aeruginosa, dialysis and biliary catheters using Escherichia coli, and urinary catheters using E. coli, Candida albicans or Enterococcus faecalis. Safety and tolerability of NO-charged urinary catheters were evaluated in a phase 1 clinical study in 12 patients. Six patients were catheterized with NO-charged catheters (NO-group), followed by 6 patients catheterized with regular control catheters (CT-group). Comparison of safety parameters between the study groups was performed. NO-charged tracheal, dialysis biliary and urinary catheters prevented P. aeruginosa, E. coli and C. albicans attachment and colonization onto their surfaces and eradicated corresponding planktonic microbial cells in the surrounding media after 24-48 hours, while E. faecalis colonization onto urinary catheters was reduced by 1 log compared to controls. All patients catheterized with an NO-charged urinary catheter successfully completed the study without experiencing NO-related AE's or serious AE's (SAE's). These data highlight the potential of NO-based technology as potential platform for preventing catheter-associated HAI's.

  4. Nitric oxide charged catheters as a potential strategy for prevention of hospital acquired infections

    PubMed Central

    Regev-Shoshani, Gili; KO, Mary; Moshe, Maya; Ozalvo, Rachel; Shavit-Grievink, Liat; Baniel, Jack; Kedar, Daniel; Yossepowitch, Ofer; Lifshitz, David; Nadu, Andrei; Greenberg, David; Av-Gay, Yossef

    2017-01-01

    Background Catheter-Associated Hospital-Acquired Infections (HAI's) are caused by biofilm-forming bacteria. Using a novel approach, we generated anti-infective barrier on catheters by charging them with Nitric Oxide (NO), a naturally-produced gas molecule. NO is slowly released from the catheter upon contact with physiological fluids, and prevents bacterial colonization and biofilm formation onto catheter surfaces. Aims and methods The aim of the study was to assess the anti-infective properties of NO-charged catheters exposed to low concentration (up to 103 CFU/ml) of microbial cells in-vitro. We assessed NO-charged tracheal tubes using Pseudomonas aeruginosa, dialysis and biliary catheters using Escherichia coli, and urinary catheters using E. coli, Candida albicans or Enterococcus faecalis. Safety and tolerability of NO-charged urinary catheters were evaluated in a phase 1 clinical study in 12 patients. Six patients were catheterized with NO-charged catheters (NO-group), followed by 6 patients catheterized with regular control catheters (CT-group). Comparison of safety parameters between the study groups was performed. Results NO-charged tracheal, dialysis biliary and urinary catheters prevented P. aeruginosa, E. coli and C. albicans attachment and colonization onto their surfaces and eradicated corresponding planktonic microbial cells in the surrounding media after 24–48 hours, while E. faecalis colonization onto urinary catheters was reduced by 1 log compared to controls. All patients catheterized with an NO-charged urinary catheter successfully completed the study without experiencing NO-related AE's or serious AE's (SAE's). Conclusion These data highlight the potential of NO-based technology as potential platform for preventing catheter-associated HAI's. PMID:28410367

  5. Micrococcus-associated central venous catheter infection in patients with pulmonary arterial hypertension.

    PubMed

    Oudiz, Ronald J; Widlitz, Allison; Beckmann, X Joy; Camanga, Daisy; Alfie, Jose; Brundage, Bruce H; Barst, Robyn J

    2004-07-01

    To determine the incidence of catheter-related infection in patients with pulmonary arterial hypertension (PAH) receiving epoprostenol (EPO), and to note an etiologic role for Micrococcus spp, which is rarely reported as a pathogen in the medical literature. Observational study. Two PAH specialty treatment centers, Harbor-UCLA Medical Center (Torrance, CA), and the College of Physicians and Surgeons, Columbia University (New York, NY). A total of 192 patients with PAH receiving continuous therapy with IV EPO. From 1987 to 2000, 192 patients with PAH received infusions of EPO via central venous catheter. Catheter care included regular dressing changes with dry gauze using a sterile procedure, without the use of flushes. Patients were asked to report on known infections and treatments, and symptoms. All infections were verified by a telephone call to the patient, care provider, and microbiology laboratory whenever possible. There were 335,285 catheter days (mean +/- SD, 1,325 +/- 974 catheter days). There were 88 clinical catheter infections with 51 blood culture-positive infections, necessitating catheter removal in 38 instances. The following pathogens were isolated: Staphylococcus aureus (25); Micrococcus spp (14); mixed flora (3); coagulase-negative Staphylococcus spp (2); Corynebacterium spp (2); Serratia marcessens (1); Enterobacter spp (1); Pseudomonas aeruginosa (1); enterococci (1); and unidentified Gram-positive cocci (1). The catheter infection rate was 0.26 per 1,000 catheter days. The use of long-term therapy with continuous EPO appears to be associated with a low incidence of catheter-related infections. Micrococcus spp were the second most common etiologic agent. Caregivers managing patients with PAH must be aware of the risk of catheter infection, as it may contribute to the morbidity and mortality associated with the use of EPO. When isolated, Micrococcus spp should not be viewed as a contaminant, but rather as a true pathogen that may require

  6. Decreasing dialysis catheter rates by creating a multidisciplinary dialysis access program.

    PubMed

    Rosenberry, Patricia M; Niederhaus, Silke V; Schweitzer, Eugene J; Leeser, David B

    2018-03-01

    Centers for Medicare and Medicaid Services have determined that chronic dialysis units should have <12% of their patients utilizing central venous catheters for hemodialysis treatments. On the Eastern Shore of Maryland, the central venous catheter rates in the dialysis units averaged >45%. A multidisciplinary program was established with goals of decreasing catheter rates in order to decrease central line-associated bloodstream infections, decrease mortality associated with central line-associated bloodstream infection, decrease hospital days, and provide savings to the healthcare system. We collected the catheter rates within three dialysis centers served over a 5-year period. Using published data surrounding the incidence and related costs of central line-associated bloodstream infection and mortality per catheter day, the number of central line-associated bloodstream infection events, the costs, and the related mortality could be determined prior to and after the initiation of the dialysis access program. An organized dialysis access program resulted in a 82% decrease in the number of central venous catheter days which lead to a concurrent reduction in central line-associated bloodstream infection and deaths. As a result of creating an access program, central venous catheter rates decreased from an average rate of 45% to 8%. The cost savings related to the program was calculated to be over US$5 million. The decrease in the number of mortalities is estimated to be between 13 and 27 patients. We conclude that a formalized access program decreases catheter rates, central line-associated bloodstream infection, and the resultant hospitalizations, mortality, and costs. Areas with high hemodialysis catheter rates should develop access programs to better serve their patient population.

  7. Accuracy of chest radiography for positioning of the umbilical venous catheter.

    PubMed

    Guimarães, Adriana F M; Souza, Aline A C G de; Bouzada, Maria Cândida F; Meira, Zilda M A

    To evaluate the accuracy of the simultaneous analysis of three radiographic anatomical landmarks - diaphragm, cardiac silhouette, and vertebral bodies - in determining the position of the umbilical venous catheter distal end using echocardiography as a reference standard. This was a cross-sectional, observational study, with the prospective inclusion of data from all neonates born in a public reference hospital, between April 2012 and September 2013, submitted to umbilical venous catheter insertion as part of their medical care. The position of the catheter distal end, determined by the simultaneous analysis of three radiographic anatomical landmarks, was compared with the anatomical position obtained by echocardiography; sensitivity, specificity, positive predictive value, negative predictive value, and accuracy were calculated. Of the 162 newborns assessed by echocardiography, only 44 (27.16%) had the catheter in optimal position, in the thoracic portion of the inferior vena cava or at the junction of the inferior vena cava with the right atrium. The catheters were located in the left atrium and interatrial septum in 54 (33.33%) newborns, in the right atrium in 26 (16.05%), intra-hepatic in 37 (22.84%), and intra-aortic in-one newborn (0.62%). The sensitivity, specificity and accuracy of the radiography to detect the catheter in the target area were 56%, 71%, and 67.28%, respectively. Anteroposterior radiography of the chest alone is not able to safely define the umbilical venous catheter position. Echocardiography allows direct visualization of the catheter tip in relation to vascular structures and, whenever possible, should be considered to identify the location of the umbilical venous catheter. Copyright © 2016 Sociedade Brasileira de Pediatria. Published by Elsevier Editora Ltda. All rights reserved.

  8. Mapping and isolation of the pulmonary veins using the PVAC catheter.

    PubMed

    Duytschaever, Mattias; Anne, Wim; Papiashvili, Giorgi; Vandekerckhove, Yves; Tavernier, Rene

    2010-02-01

    We aimed to investigate the feasibility, efficacy, and safety of the pulmonary vein ablation catheter (PVAC) catheter (a novel multielectrode catheter using duty-cycled bipolar and unipolar radiofrequency energy, Medtronic, Minneapolis, MN, USA) to completely isolate the pulmonary veins (PVs). Twenty-seven patients (60 +/- 8 years) with paroxysmal atrial fibrillation (AF) underwent PV isolation with the PVAC catheter. PVAC was used for both mapping and isolation of the PVs (PVAC-guided ablation). After PVAC ablation, presence/absence of PV potentials (PVP) was verified using a conventional circular mapping catheter. In case of residual PVP on the circular catheter, PVAC ablation was continued. After PVAC-guided ablation 99 of 106 PVs (93%) and 21 of 27 patients (78%) were proven to be isolated. Failure to isolate was due to a mapping failure in four right-sided PVs and a true ablation failure in three right-sided PVs. After continued PVAC ablation, 103 of 106 PVs (97%) and 25 of 27 patients (93%) were shown to be isolated. The total procedural time from femoral vein access to complete catheter withdrawal was 176 +/- 25 minutes. The actual dwelling-time of the PVAC within the left atrium was 102 +/- 37 minutes. Esophageal T degrees rise to >38.5 degrees occurred in nine of 19 monitored patients (47%). (1) PVAC-guided ablation (i.e., mapping and ablation with a single catheter) results in isolation of all PVs in 73% of the patients. (2) An additional circular mapping catheter is required to increase complete isolation rate to 93% of the patients. (3) Given the esophageal T degrees rise in almost 50% of patients, safety precautions are needed.

  9. Magnetic resonance imaging compatible remote catheter navigation system with 3 degrees of freedom.

    PubMed

    Tavallaei, M A; Lavdas, M K; Gelman, D; Drangova, M

    2016-08-01

    To facilitate MRI-guided catheterization procedures, we present an MRI-compatible remote catheter navigation system that allows remote navigation of steerable catheters with 3 degrees of freedom. The system consists of a user interface (master), a robot (slave), and an ultrasonic motor control servomechanism. The interventionalist applies conventional motions (axial, radial and plunger manipulations) on an input catheter in the master unit; this user input is measured and used by the servomechanism to control a compact catheter manipulating robot, such that it replicates the interventionalist's input motion on the patient catheter. The performance of the system was evaluated in terms of MRI compatibility (SNR and artifact), feasibility of remote navigation under real-time MRI guidance, and motion replication accuracy. Real-time MRI experiments demonstrated that catheter was successfully navigated remotely to desired target references in all 3 degrees of freedom. The system had an absolute value error of [Formula: see text]1 mm in axial catheter motion replication over 30 mm of travel and [Formula: see text] for radial catheter motion replication over [Formula: see text]. The worst case SNR drop was observed to be [Formula: see text]3 %; the robot did not introduce any artifacts in the MR images. An MRI-compatible compact remote catheter navigation system has been developed that allows remote navigation of steerable catheters with 3 degrees of freedom. The proposed system allows for safe and accurate remote catheter navigation, within conventional closed-bore scanners, without degrading MR image quality.

  10. Empyema and effusion: outcome of image-guided small-bore catheter drainage.

    PubMed

    Keeling, A N; Leong, S; Logan, P M; Lee, M J

    2008-01-01

    Empyema and complicated pleural effusion represent common medical problems. Current treatment options are multiple. The purpose of this study was to access the outcome of image-guided, small-bore catheter drainage of empyema and effusion. We evaluated 93 small-bore catheters in 82 patients with pleural effusion (n = 30) or empyema (n = 52), over a 2-year period. Image guidance was with ultrasound (US; n = 56) and CT (n = 37). All patients were followed clinically, with catheter dwell times, catheter outcome, pleural fluid outcome, reinsertion rates, and need for urokinase or surgery recorded. Ninety-three small-bore chest drains (mean=10.2 Fr; range, 8.2-12.2 Fr) were inserted, with an average dwell time of 7.81 days for empyemas and 7.14 days for effusions (p > 0.05). Elective removal rates (73% empyema vs 86% effusions) and dislodgement rates (12% empyema vs 13% effusions) were similar for both groups. Eight percent of catheters became blocked and 17% necessitated reinsertion in empyemas, with no catheters blocked or requiring reinsertion in effusions (p < 0.05). Thirty-two patients (51%) required urokinase in the empyema group, versus 2 patients (6%) in the effusion group (p < 0.05). All treatment failures, requiring surgery, occurred in the empyema group (19%; n = 12; p < 0.05). In conclusion, noninfected pleural collections are adequately treated with small-bore catheters, however, empyemas have a failure rate of 19%. The threshold for using urokinase and larger-bore catheters should be low in empyema.

  11. Between the lines: The 50th anniversary of long-term central venous catheters.

    PubMed

    Gow, Kenneth W; Tapper, David; Hickman, Robert O

    2017-05-01

    Tunneled central venous catheters (CVC) were developed five decades ago. Since then, several clinician-inventors have created a variety of catheters with different functions. Indeed, many catheters have been named after their inventor. Many have wondered who the inventors were of each catheter, and what specifically inspired their inventions. Many of these compelling stories have yet to be told. A literature review of common catheters and personal communication with inventors. Only first person accounts from inventors or those close to the invention were used. CVCs are now essential devices that have saved countless lives. Though the inventors have earned the honor of naming their catheters, it may be reasonable to consider more consistent terminology to describe these catheters to avoid confusion. Copyright © 2017 Elsevier Inc. All rights reserved.

  12. The role of laparoscopic surgery in the management of a malfunctioning peritoneal catheter.

    PubMed

    Alabi, A; Dholakia, S; Ablorsu, E

    2014-11-01

    Peritoneal catheter malfunction is a common complication of peritoneal dialysis (PD). It has a high failure rate with conservative management. Catheter replacement was historically the standard surgical treatment of choice. Nowadays, laparoscopy has been introduced as an alternative surgical modality to rescue the malfunctioning peritoneal catheter and also offers the possibility of replacement if indicated. The aim of this study was to compare the outcomes of these two surgical modalities. The medical records of consecutive patients who underwent surgical treatment for malfunctioning PD catheters (between January 2010 and April 2013) were analysed. The primary outcome included successful return to adequate PD. The secondary endpoint was length of catheter patency and the cause of catheter failure. A total of 32 cases were identified, of which 8 had open catheter replacement and 24 had a laparoscopic intervention. The overall median follow-up duration was 12.5 months. The success rate for laparoscopic surgery in terms of functioning catheter at 12 months was 62.5% but only 37.5% for open surgery. The mean length of catheter patency after laparoscopic intervention was 31.6 months compared with only 13.6 months for the open surgery group. The most common cause of catheter failure diagnosed during laparoscopic intervention was catheter migration (33.0%), followed by omental wrap and catheter blockage by fibrin/blood plug (25.0% each). Open surgery did not have any diagnostic potential. Laparoscopy is the treatment of choice for malfunctioning PD. Its proven benefit includes simultaneous identification of the aetiological cause of malfunction together with direct correction of this problem, thereby maximising outcome. It also allows for rapid recommencement of PD and avoidance of haemodialysis, saving cost and resources.

  13. A comparative assessment of irrigation and drainage characteristics for commercially available urethral catheters

    PubMed Central

    Davis, Niall F.; McMahon, Barry P.; Walsh, Michael; McDermott, Thomas E.D.; Thornhill, John A.; Manecksha, Rustom P.

    2017-01-01

    Introduction We aimed to investigate irrigation and drainage characteristics of commercially available urethral catheters and determined which catheter offers the best flow characteristics. Material and methods Twelve different commercially available urethral catheters from three companies (Bard™, Rusch™ and Dover™) were investigated to compare their irrigation and drainage properties. Irrigation port, drainage port and overall cross-sectional areas for a 24Fr 3-way catheter was measured and compared. The maximum (Qmax) and average (Qavg) irrigation and drainage flow rates for each catheter was measured for 20–40 seconds using uroflowmetry. The primary endpoint was to determine which catheter offers optimal irrigation and drainage parameters. Results Overall cross-sectional area, irrigation port cross-sectional area, and drainage port cross-sectional area differed significantly for each 24Fr 3-way catheter assessed (p <0.001). The 24Fr 3-way Rusch Simplastic™ catheter consistently demonstrated the greatest maximal flow rate (Qmax: 5 ±0.3 ml/s) and average flow rate (Qavg: 4.6 ±0.2 ml/s) for irrigation. The 24Fr 3-way Dover™ catheter provided the greatest drainage properties (Qmax: 19.7 ±2 ml/s; Q avg: 15.9 ±5 ml/s). In the setting of continuous bladder irrigation, the 24Fr 3-way Rusch Simplastic™ catheter provided the highest irrigation rates (Qmax: 6.6 ±1.8 ml/s; Q avg: 4.6 ±0.9 ml/s). Conclusions Three-way catheters demonstrate significant differences in their irrigation and drainage characteristics. The type of catheter selected should be based on the appropriate prioritization of efficient bladder irrigation versus efficient bladder drainage. PMID:29410890

  14. Guide Catheter Extension Device Is Effective in Renal Angioplasty for Severely Calcified Lesions

    PubMed Central

    Sugimoto, Takeshi; Nomura, Tetsuya; Hori, Yusuke; Yoshioka, Kenichi; Kubota, Hiroshi; Miyawaki, Daisuke; Urata, Ryota; Kikai, Masakazu; Keira, Natsuya; Tatsumi, Tetsuya

    2017-01-01

    Patient: Male, 69 Final Diagnosis: Atherosclerotic renal artery stenosis Symptoms: None Medication: — Clinical Procedure: — Specialty: Radiology Objective: Unusual setting of medical care Background: The GuideLiner catheter extension device is a monorail-type “Child” support catheter that facilitates coaxial alignment with the guide catheter and provides an appropriate back-up force. This device has been developed in the field of coronary intervention, and now is becoming widely applied in the field of endovascular treatment. However, there has been no report on the effectiveness of the guide catheter extension device in percutaneous transluminal renal angioplasty (PTRA). Case Report: We encountered a case of atherosclerotic subtotal occlusion at the ostium of the left renal artery. Due to the severely calcified orifice and weaker back-up force provided by a JR4 guide catheter, we could not pass any guide-wires through the target lesion. Therefore, we introduced a guide catheter extension device, the GuideLiner catheter, through the guide catheter and achieved good guidewire maneuverability. We finally deployed 2 balloon-expandable stents and successfully performed all PTRA procedures. Conclusions: The guide catheter extension device can be effective in PTRA for severely calcified subtotal occlusion. PMID:28533503

  15. Pressure-volume behavior of the upper airway.

    PubMed

    Fouke, J M; Teeter, J P; Strohl, K P

    1986-09-01

    The study was performed to investigate the relationship between force generation and upper airway expansion during respiratory efforts by upper airway muscles. In 11 anesthetized dogs we isolated the upper airway (nasal, oral, pharyngeal, and laryngeal regions) by transecting the cervical trachea and sealing the nasal and oral openings. During spontaneous respiratory efforts the pressure within the sealed upper airway, used as an index of dilating force, decreased during inspiration. On alternate breaths the upper airway was opened to a pneumotachograph, and an increase in volume occurred, also during inspiration. Progressive hyperoxic hypercapnia produced by rebreathing increased the magnitude of change in pressure and volume. At any level of drive, peak pressure or volume occurred at the same point during inspiration. At any level of drive, volume and pressure changes increased with end-expiratory occlusion of the trachea. The force-volume relationship determined from measurements during rebreathing was compared with pressure-volume curves performed by passive inflation of the airway while the animal was apneic. The relationship during apnea was 1.06 +/- 0.55 (SD) ml/cmH2O, while the force-volume relationship from rebreathing trials was -1.09 +/- 0.45 ml/cmH2O. We conclude that there is a correspondence between force production and volume expansion in the upper airway during active respiratory efforts.

  16. Changing concepts in long-term central venous access: catheter selection and cost savings.

    PubMed

    Horattas, M C; Trupiano, J; Hopkins, S; Pasini, D; Martino, C; Murty, A

    2001-02-01

    Long-term central venous access is becoming an increasingly important component of health care today. Long-term central venous access is important therapeutically for a multitude of reasons, including the administration of chemotherapy, antibiotics, and total parenteral nutrition. Central venous access can be established in a variety of ways varying from catheters inserted at the bedside to surgically placed ports. Furthermore, in an effort to control costs, many traditionally inpatient therapies have moved to an outpatient setting. This raises many questions regarding catheter selection. Which catheter will result in the best outcome at the least cost? It has become apparent in our hospital that traditionally placed surgical catheters (ie, Hickmans and central venous ports) may no longer be the only options. The objective of this study was to explore the various modalities for establishing central venous access comparing indications, costs, and complications to guide the clinician in choosing the appropriate catheter with the best outcome at the least cost. We evaluated our institution's central venous catheter use during a 3-year period from 1995 through 1997. Data was obtained retrospectively through chart review. In addition to demographic data, specific information regarding catheter type, placement technique, indications, complications, and catheter history were recorded. Cost data were obtained from several departments including surgery, radiology, nursing, anesthesia, pharmacy, and the hospital purchasing department. During a 30-month period, 684 attempted central venous catheter insertions were identified, including 126 surgically placed central venous catheters, 264 peripherally inserted central catheters by the nursing service, and 294 radiologically inserted peripheral ports. Overall complications were rare but tended to be more severe in the surgical group. Relative cost differences between the groups were significant. Charges for peripherally inserted

  17. Review of advanced catheter technologies in radiation oncology brachytherapy procedures

    PubMed Central

    Zhou, Jun; Zamdborg, Leonid; Sebastian, Evelyn

    2015-01-01

    The development of new catheter and applicator technologies in recent years has significantly improved treatment accuracy, efficiency, and outcomes in brachytherapy. In this paper, we review these advances, focusing on the performance of catheter imaging and reconstruction techniques in brachytherapy procedures using magnetic resonance images and electromagnetic tracking. The accuracy of catheter reconstruction, imaging artifacts, and other notable properties of plastic and titanium applicators in gynecologic treatments are reviewed. The accuracy, noise performance, and limitations of electromagnetic tracking for catheter reconstruction are discussed. Several newly developed applicators for accelerated partial breast irradiation and gynecologic treatments are also reviewed. New hypofractionated high dose rate treatment schemes in prostate cancer and accelerated partial breast irradiation are presented. PMID:26203277

  18. Intraluminal laser speckle rheology using an omni-directional viewing catheter

    PubMed Central

    Wang, Jing; Hosoda, Masaki; Tshikudi, Diane M.; Hajjarian, Zeinab; Nadkarni, Seemantini K.

    2016-01-01

    A number of disease conditions in luminal organs are associated with alterations in tissue mechanical properties. Here, we report a new omni-directional viewing Laser Speckle Rheology (LSR) catheter for mapping the mechanical properties of luminal organs without the need for rotational motion. The LSR catheter incorporates multiple illumination fibers, an optical fiber bundle and a multi-faceted mirror to permit omni-directional viewing of the luminal wall. By retracting the catheter using a motor-drive assembly, cylindrical maps of tissue mechanical properties are reconstructed. Evaluation conducted in a test phantom with circumferentially-varying mechanical properties demonstrates the capability of the LSR catheter for the accurate mechanical assessment of luminal organs. PMID:28101407

  19. Durability of Silicone Airway Stents in the Management of Benign Central Airway Obstruction.

    PubMed

    Karush, Justin M; Seder, Christopher W; Raman, Anish; Chmielewski, Gary W; Liptay, Michael J; Warren, William H; Arndt, Andrew T

    2017-10-01

    The literature is devoid of a comprehensive analysis of silicone airway stenting for benign central airway obstruction (BCAO). With the largest series in the literature to date, we aim to demonstrate the safety profile, pattern of re-intervention, and duration of silicone airway stents. An institutional database was used to identify patients with BCAO who underwent rigid bronchoscopy with dilation and silicone stent placement between 2002 and 2015 at Rush University Medical Center. During the study period, 243 stents were utilized in 63 patients with BCAO. Pure tracheal stenosis was encountered in 71% (45/63), pure tracheomalacia in 11% (7/63), and a hybrid of both in 17% (11/63). Median freedom from re-intervention was 104 (IQR 167) days. Most common indications for re-intervention include mucus accumulation (60%; 131/220), migration (28%; 62/220), and intubation (8%; 18/220). The most common diameters of stent placed were 12 mm (94/220) and 14 mm (96/220). The most common lengths utilized were 30 mm (60/220) and 40 mm (77/220). Duration was not effected by stent size when placed for discrete stenosis. However, 14 mm stents outperformed 12 mm when tracheomalacia was present (157 vs. 37 days; p = 0.005). Patients with a hybrid stenosis fared better when longer stents were used (60 mm stents outlasted 40 mm stents 173 vs. 56 days; p = 0.05). Rigid bronchoscopy with silicone airway stenting is a safe and effective option for the management of benign central airway obstruction. Our results highlight several strategies to improve stent duration.

  20. [Comparative study of PTFE grafts in forearm vs cuffed permanent catheters].

    PubMed

    Moyano, M J; Salgueira, M; Aresté, N; Escalera, B; del Toro, N; Jiménez-Víbora, E; Martínez-Puerto, A I; Molas, J R; Palma, A

    2006-01-01

    As is universally accepted the best form of permanent vascular access for haemodialysis is the native arteriovenous fistula. A second and third options are the politetrafluoroethylene (PTFE) AV grafts and the cuffed, tunneled, internal catheters. The overall performance and complications of catheters is clearly inferior to AV fistula. There are not many studies that compare permanent catheters to grafts in terms of functionality, survival and complications. We analyzed 81 vascular accesses carried out from october 99 to december 03 in 59 patients and during a follow-up period of 35 months. Two groups were considered. Group 1, catheters (n 42) and group 2, grafts (n 39). Clinical aspects, comorbidity index (Wright and Kanh), dialysis dose and complications and survival of the access were registered. Both groups were similar in age, sex, time on haemodialysis, number of previous accesses and hospitalization days. Cardiovascular morbidity and comorbidity index were significantly higher in patients with catheter. While blood flow during dialysis was higher in grafts both groups showed no significant differences in parameters of efficacy of dialysis (Kt/V, TAC BUN and PCRn). Serum albumin was lower in patients with catheter. The number of accesses that failed was higher in the graft group being thrombosis the main complication followed by infection. Kaplan-Meier curves showed better accumulated survival of permanent catheters versus grafts (61,4% vs 9,8% at 35 months). The most frequent complication of catheter was infection while in the case of grafts it was thrombosis followed by infection. Although they were placed in patients with higher comorbidity, cuffed, tunneled catheters showed less number of complications and better survival than PTFE grafts in our patients in haemodialysis. The main cause of failure of both vascular access was thrombosis followed by infection. The dose of dialysis obtained was no different in both groups. Cuffed, tunneled permanent catheters