Sample records for allowable working pressure

  1. 46 CFR 151.03-37 - Maximum allowable working pressure.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 5 2013-10-01 2013-10-01 false Maximum allowable working pressure. 151.03-37 Section 151.03-37 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) CERTAIN BULK DANGEROUS CARGOES BARGES CARRYING BULK LIQUID HAZARDOUS MATERIAL CARGOES Definitions § 151.03-37 Maximum allowable working pressure. The maximum allowable working...

  2. 46 CFR 151.03-37 - Maximum allowable working pressure.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 5 2012-10-01 2012-10-01 false Maximum allowable working pressure. 151.03-37 Section 151.03-37 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) CERTAIN BULK DANGEROUS CARGOES BARGES CARRYING BULK LIQUID HAZARDOUS MATERIAL CARGOES Definitions § 151.03-37 Maximum allowable working pressure. The maximum allowable working...

  3. 46 CFR 151.03-37 - Maximum allowable working pressure.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 5 2011-10-01 2011-10-01 false Maximum allowable working pressure. 151.03-37 Section 151.03-37 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) CERTAIN BULK DANGEROUS CARGOES BARGES CARRYING BULK LIQUID HAZARDOUS MATERIAL CARGOES Definitions § 151.03-37 Maximum allowable working pressure. The maximum allowable working...

  4. 46 CFR 151.03-37 - Maximum allowable working pressure.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 5 2010-10-01 2010-10-01 false Maximum allowable working pressure. 151.03-37 Section 151.03-37 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) CERTAIN BULK DANGEROUS CARGOES BARGES CARRYING BULK LIQUID HAZARDOUS MATERIAL CARGOES Definitions § 151.03-37 Maximum allowable working pressure. The maximum allowable working...

  5. 46 CFR 151.03-37 - Maximum allowable working pressure.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 5 2014-10-01 2014-10-01 false Maximum allowable working pressure. 151.03-37 Section 151.03-37 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) CERTAIN BULK DANGEROUS CARGOES BARGES CARRYING BULK LIQUID HAZARDOUS MATERIAL CARGOES Definitions § 151.03-37 Maximum allowable working pressure. The maximum allowable working...

  6. 46 CFR 54.10-5 - Maximum allowable working pressure (reproduces UG-98).

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 2 2013-10-01 2013-10-01 false Maximum allowable working pressure (reproduces UG-98). 54.10-5 Section 54.10-5 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING PRESSURE VESSELS Inspection, Reports, and Stamping § 54.10-5 Maximum allowable working pressure (reproduces UG-98). (a) The maximum allowable...

  7. 46 CFR 54.10-5 - Maximum allowable working pressure (reproduces UG-98).

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 2 2011-10-01 2011-10-01 false Maximum allowable working pressure (reproduces UG-98). 54.10-5 Section 54.10-5 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING PRESSURE VESSELS Inspection, Reports, and Stamping § 54.10-5 Maximum allowable working pressure (reproduces UG-98). (a) The maximum allowable...

  8. 46 CFR 54.10-5 - Maximum allowable working pressure (reproduces UG-98).

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 2 2014-10-01 2014-10-01 false Maximum allowable working pressure (reproduces UG-98). 54.10-5 Section 54.10-5 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING PRESSURE VESSELS Inspection, Reports, and Stamping § 54.10-5 Maximum allowable working pressure (reproduces UG-98). (a) The maximum allowable...

  9. 46 CFR 54.10-5 - Maximum allowable working pressure (reproduces UG-98).

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 2 2012-10-01 2012-10-01 false Maximum allowable working pressure (reproduces UG-98). 54.10-5 Section 54.10-5 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING PRESSURE VESSELS Inspection, Reports, and Stamping § 54.10-5 Maximum allowable working pressure (reproduces UG-98). (a) The maximum allowable...

  10. 46 CFR 52.01-55 - Increase in maximum allowable working pressure.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 2 2011-10-01 2011-10-01 false Increase in maximum allowable working pressure. 52.01-55 Section 52.01-55 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING POWER BOILERS General Requirements § 52.01-55 Increase in maximum allowable working pressure. (a) When...

  11. 46 CFR 52.01-55 - Increase in maximum allowable working pressure.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 2 2012-10-01 2012-10-01 false Increase in maximum allowable working pressure. 52.01-55 Section 52.01-55 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING POWER BOILERS General Requirements § 52.01-55 Increase in maximum allowable working pressure. (a) When...

  12. 46 CFR 52.01-55 - Increase in maximum allowable working pressure.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 2 2010-10-01 2010-10-01 false Increase in maximum allowable working pressure. 52.01-55 Section 52.01-55 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING POWER BOILERS General Requirements § 52.01-55 Increase in maximum allowable working pressure. (a) When...

  13. 46 CFR 52.01-55 - Increase in maximum allowable working pressure.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 2 2014-10-01 2014-10-01 false Increase in maximum allowable working pressure. 52.01-55 Section 52.01-55 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING POWER BOILERS General Requirements § 52.01-55 Increase in maximum allowable working pressure. (a) When...

  14. 46 CFR 52.01-55 - Increase in maximum allowable working pressure.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 2 2013-10-01 2013-10-01 false Increase in maximum allowable working pressure. 52.01-55 Section 52.01-55 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING POWER BOILERS General Requirements § 52.01-55 Increase in maximum allowable working pressure. (a) When...

  15. 46 CFR 54.10-5 - Maximum allowable working pressure (reproduces UG-98).

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... section VIII of the ASME Boiler and Pressure Vessel Code, together with the effect of any combination of... operating temperature, using for each temperature the applicable allowable stress value. Note: Table 54.10-5...

  16. 49 CFR 192.621 - Maximum allowable operating pressure: High-pressure distribution systems.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... STANDARDS Operations § 192.621 Maximum allowable operating pressure: High-pressure distribution systems. (a) No person may operate a segment of a high pressure distribution system at a pressure that exceeds the... segment of a distribution system otherwise designed to operate at over 60 p.s.i. (414 kPa) gage, unless...

  17. 49 CFR 192.621 - Maximum allowable operating pressure: High-pressure distribution systems.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... STANDARDS Operations § 192.621 Maximum allowable operating pressure: High-pressure distribution systems. (a) No person may operate a segment of a high pressure distribution system at a pressure that exceeds the... segment of a distribution system otherwise designed to operate at over 60 p.s.i. (414 kPa) gage, unless...

  18. 49 CFR 192.621 - Maximum allowable operating pressure: High-pressure distribution systems.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... STANDARDS Operations § 192.621 Maximum allowable operating pressure: High-pressure distribution systems. (a) No person may operate a segment of a high pressure distribution system at a pressure that exceeds the... segment of a distribution system otherwise designed to operate at over 60 p.s.i. (414 kPa) gage, unless...

  19. 49 CFR 192.621 - Maximum allowable operating pressure: High-pressure distribution systems.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... STANDARDS Operations § 192.621 Maximum allowable operating pressure: High-pressure distribution systems. (a) No person may operate a segment of a high pressure distribution system at a pressure that exceeds the... segment of a distribution system otherwise designed to operate at over 60 p.s.i. (414 kPa) gage, unless...

  20. 49 CFR 192.621 - Maximum allowable operating pressure: High-pressure distribution systems.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... STANDARDS Operations § 192.621 Maximum allowable operating pressure: High-pressure distribution systems. (a) No person may operate a segment of a high pressure distribution system at a pressure that exceeds the... segment of a distribution system otherwise designed to operate at over 60 p.s.i. (414 kPa) gage, unless...

  1. 49 CFR 192.623 - Maximum and minimum allowable operating pressure; Low-pressure distribution systems.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... distribution systems. (a) No person may operate a low-pressure distribution system at a pressure high enough to...) No person may operate a low pressure distribution system at a pressure lower than the minimum... 49 Transportation 3 2012-10-01 2012-10-01 false Maximum and minimum allowable operating pressure...

  2. 49 CFR 192.623 - Maximum and minimum allowable operating pressure; Low-pressure distribution systems.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... distribution systems. (a) No person may operate a low-pressure distribution system at a pressure high enough to...) No person may operate a low pressure distribution system at a pressure lower than the minimum... 49 Transportation 3 2011-10-01 2011-10-01 false Maximum and minimum allowable operating pressure...

  3. 49 CFR 192.623 - Maximum and minimum allowable operating pressure; Low-pressure distribution systems.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... distribution systems. (a) No person may operate a low-pressure distribution system at a pressure high enough to...) No person may operate a low pressure distribution system at a pressure lower than the minimum... 49 Transportation 3 2013-10-01 2013-10-01 false Maximum and minimum allowable operating pressure...

  4. 49 CFR 192.623 - Maximum and minimum allowable operating pressure; Low-pressure distribution systems.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... distribution systems. (a) No person may operate a low-pressure distribution system at a pressure high enough to...) No person may operate a low pressure distribution system at a pressure lower than the minimum... 49 Transportation 3 2014-10-01 2014-10-01 false Maximum and minimum allowable operating pressure...

  5. 49 CFR 192.623 - Maximum and minimum allowable operating pressure; Low-pressure distribution systems.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... distribution systems. (a) No person may operate a low-pressure distribution system at a pressure high enough to...) No person may operate a low pressure distribution system at a pressure lower than the minimum... 49 Transportation 3 2010-10-01 2010-10-01 false Maximum and minimum allowable operating pressure...

  6. 38 CFR 21.4145 - Work-study allowance.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 38 Pensions, Bonuses, and Veterans' Relief 2 2010-07-01 2010-07-01 false Work-study allowance. 21...; Educational Assistance Allowance § 21.4145 Work-study allowance. (a) Eligibility. (1) A veteran or reservist... rate of three-quarter time or full time is eligible to receive a work-study allowance. (2) An eligible...

  7. 38 CFR 21.4145 - Work-study allowance.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 38 Pensions, Bonuses, and Veterans' Relief 2 2011-07-01 2011-07-01 false Work-study allowance. 21...; Educational Assistance Allowance § 21.4145 Work-study allowance. (a) Eligibility. (1) A veteran or reservist... rate of three-quarter time or full time is eligible to receive a work-study allowance. (2) An eligible...

  8. 49 CFR 192.619 - Maximum allowable operating pressure: Steel or plastic pipelines.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 3 2013-10-01 2013-10-01 false Maximum allowable operating pressure: Steel or... Operations § 192.619 Maximum allowable operating pressure: Steel or plastic pipelines. (a) No person may operate a segment of steel or plastic pipeline at a pressure that exceeds a maximum allowable operating...

  9. 49 CFR 192.619 - Maximum allowable operating pressure: Steel or plastic pipelines.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 3 2011-10-01 2011-10-01 false Maximum allowable operating pressure: Steel or... Operations § 192.619 Maximum allowable operating pressure: Steel or plastic pipelines. (a) No person may operate a segment of steel or plastic pipeline at a pressure that exceeds a maximum allowable operating...

  10. 49 CFR 192.619 - Maximum allowable operating pressure: Steel or plastic pipelines.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 3 2012-10-01 2012-10-01 false Maximum allowable operating pressure: Steel or... Operations § 192.619 Maximum allowable operating pressure: Steel or plastic pipelines. (a) No person may operate a segment of steel or plastic pipeline at a pressure that exceeds a maximum allowable operating...

  11. 49 CFR 192.619 - Maximum allowable operating pressure: Steel or plastic pipelines.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 3 2014-10-01 2014-10-01 false Maximum allowable operating pressure: Steel or... Operations § 192.619 Maximum allowable operating pressure: Steel or plastic pipelines. (a) No person may operate a segment of steel or plastic pipeline at a pressure that exceeds a maximum allowable operating...

  12. 38 CFR 21.9670 - Work-study allowance.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 38 Pensions, Bonuses, and Veterans' Relief 2 2011-07-01 2011-07-01 false Work-study allowance. 21...-study allowance. An eligible individual pursuing a program of education under 38 U.S.C. chapter 33 at a rate of pursuit of at least 75 percent may receive a work-study allowance in accordance with the...

  13. 38 CFR 21.9670 - Work-study allowance.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 38 Pensions, Bonuses, and Veterans' Relief 2 2010-07-01 2010-07-01 false Work-study allowance. 21...-study allowance. An eligible individual pursuing a program of education under 38 U.S.C. chapter 33 at a rate of pursuit of at least 75 percent may receive a work-study allowance in accordance with the...

  14. 49 CFR 192.619 - Maximum allowable operating pressure: Steel or plastic pipelines.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... plastic pipelines. 192.619 Section 192.619 Transportation Other Regulations Relating to Transportation... Operations § 192.619 Maximum allowable operating pressure: Steel or plastic pipelines. (a) No person may operate a segment of steel or plastic pipeline at a pressure that exceeds a maximum allowable operating...

  15. Raising the Bar: Increased Hydraulic Pressure Allows Unprecedented High Power Densities in Pressure-Retarded Osmosis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Straub, AP; Yip, NY; Elimelech, M

    2014-01-01

    Pressure-retarded osmosis (PRO) has the potential to generate sustainable energy from salinity gradients. PRO is typically considered for operation with river water and seawater, but a far greater energy of mixing can be harnessed from hypersaline solutions. This study investigates the power density that can be obtained in PRO from such concentrated solutions. Thin-film composite membranes with an embedded woven mesh were supported by tricot fabric feed spacers in a specially designed crossflow cell to maximize the operating pressure of the system, reaching a stable applied hydraulic pressure of 48 bar (700 psi) for more than 10 h. Operation atmore » this increased hydraulic pressure allowed unprecedented power densities, up to 60 W/m(2) with a 3 M (180 g/L) NaCl draw solution. Experimental power densities demonstrate reasonable agreement with power densities modeled using measured membrane properties, indicating high-pressure operation does not drastically alter membrane performance. Our findings exhibit the promise of the generation of power from high-pressure PRO with concentrated solutions.« less

  16. Work Status, Work Satisfaction, and Blood Pressure Among Married Black and White Women

    ERIC Educational Resources Information Center

    Hauenstein, Louise S.; And Others

    1977-01-01

    This study examined blood pressure levels of married women in relation to such work-related variables as work load, satisfaction with work, reported strain, and evaluated performance. Differences in work load were unrelated to blood pressure levels. However, currently unemployed working women had lower levels. (Author)

  17. Postadsorption Work Function Tuning via Hydrogen Pressure Control

    PubMed Central

    2015-01-01

    The work function of metal substrates can be easily tuned, for instance, by adsorbing layers of molecular electron donors and acceptors. In this work, we discuss the possibility of changing the donor/acceptor mixing ratio reversibly after adsorption by choosing a donor/acceptor pair that is coupled via a redox reaction and that is in equilibrium with a surrounding gas phase. We discuss such a situation for the example of tetrafluoro-1,4-benzenediol (TFBD)/tetrafluoro-1,4-benzoquinone (TFBQ), adsorbed on Cu(111) and Ag(111) surfaces. We use density functional theory and ab initio thermodynamics to show that arbitrary TFBD/TFBQ mixing ratios can be set using hydrogen pressures attainable in low to ultrahigh vacuum. Adjusting the mixing ratio allows modifying the work function over a range of about 1 eV. Finally, we contrast single-species submonolayers with mixed layers to discuss why the resulting inhomogeneities in the electrostatic energy above the surface have different impacts on the interfacial level alignment and the work function. PMID:26692915

  18. [Shift work and night work: what effect on blood pressure?].

    PubMed

    Cassat, M; Wuerzner, G; Burnier, M

    2015-09-09

    Shift work has become more and more common for the last thirty years. By definition, shift work disturbs the circadian rhythm and the internal clock. Even if the pathophysiological mechanisms are not well understood, a greater cardiovascular risk has been attributed to shift work. Cross-sectional and cohort studies have identified an association between shift work and an elevated blood pressure. Shift workers also present a higher incidence of hypertension and progression than day workers. Unfortunately, the heterogeneity of the studies, the multiple confounding factors, as well as the complexity to achieve a suitable comparison group make it impossible to draw firm clinical evidence. Nevertheless, this population needs a medical follow-up focused on the cardiovascular risks and blood pressure.

  19. 49 CFR 192.620 - Alternative maximum allowable operating pressure for certain steel pipelines.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... for certain steel pipelines. 192.620 Section 192.620 Transportation Other Regulations Relating to... STANDARDS Operations § 192.620 Alternative maximum allowable operating pressure for certain steel pipelines..., 2, or 3 location; (2) The pipeline segment is constructed of steel pipe meeting the additional...

  20. 49 CFR 192.620 - Alternative maximum allowable operating pressure for certain steel pipelines.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... of a maximum allowable operating pressure based on higher stress levels in the following areas: Take... pipeline at the increased stress level under this section with conventional operation; and (ii) Describe... targeted audience; and (B) Include information about the integrity management activities performed under...

  1. 49 CFR 192.620 - Alternative maximum allowable operating pressure for certain steel pipelines.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... of a maximum allowable operating pressure based on higher stress levels in the following areas: Take... pipeline at the increased stress level under this section with conventional operation; and (ii) Describe... targeted audience; and (B) Include information about the integrity management activities performed under...

  2. 49 CFR 192.620 - Alternative maximum allowable operating pressure for certain steel pipelines.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... of a maximum allowable operating pressure based on higher stress levels in the following areas: Take... pipeline at the increased stress level under this section with conventional operation; and (ii) Describe... targeted audience; and (B) Include information about the integrity management activities performed under...

  3. What happens at work stays at work? Workplace supervisory social interactions and blood pressure outcomes.

    PubMed

    Wong, Jennifer H K; Kelloway, E Kevin

    2016-04-01

    We investigated the relationship between workplace supervisory social interactions and blood pressure outcomes using hourly diary entries and ambulatory blood pressure data from an experience sampling study of 55 long-term care employees. After accounting for relevant cardiovascular controls, significant effects of supervisory interactions on cardiovascular reactivity and recovery were found. Multilevel analyses revealed that negatively perceived supervisory interactions predicted higher systolic blood pressure at work (B = -1.59, p < .05, N observations = 422). Using time-lagged hierarchical regression analyses, the average perceived valence of supervisory interactions at work predicted average systolic blood pressure recovery after work (B = -14.52, p < .05, N = 33). Specifically, negatively perceived supervisory interactions at work predicted poorer cardiovascular recovery after work. Suggestions for improving practices in organizations and in experience sampling research are discussed. (c) 2016 APA, all rights reserved).

  4. A Broad Continuum of Aeolian Impact Ripple Sizes on Mars is Allowed by Low Dynamic Wind Pressures

    NASA Astrophysics Data System (ADS)

    Sullivan, R. J., Jr.; Kok, J. F.; Yizhaq, H.

    2017-12-01

    Aeolian impact ripples are generated by impacts of wind-blown sand grains, and are common in environments with loose sand on Earth and Mars. Previous work has shown that, within a fully developed saltation cloud, impact ripple height grows upward into the boundary layer until limited by the effects of increasing wind dynamic pressure at the crest (e.g., lengthening of splash trajectories, or direct entrainment of grains by the wind). On Earth, this process limits ripples of well-sorted 250 µm dune sands to heights of millimeters, and strong winds can impose sufficient lateral dynamic pressure to flatten and erase these ripples. Rover observations show much larger ripple-like bedforms on Mars, raising questions about their formative mechanism. Here, we hypothesize that two factors allow impact ripples to grow much higher on Mars than on Earth: (1) previous work predicts a much larger difference between impact threshold and fluid threshold wind speeds on Mars than on Earth; and (2) recent analysis has revealed how low saltation flux can be initiated and sustained well below fluid threshold on Mars, allowing impact ripples to migrate entirely under prevailing conditions of relatively low wind speeds in the thin martian atmosphere. Under these circumstances, martian ripples would need to grow much larger than on Earth before reaching their maximum height limited by wind dynamic pressure effects. Because the initial size of impact ripples is similar on Mars and Earth, this should generate a much broader continuum of impact ripple sizes on Mars. Compared with Earth, far more time should be needed on Mars for impact ripples to achieve their maximum possible size. Consequently, in cases where wind azimuths are mixed but one azimuth is more dominant than others, martian impact ripples of all sizes can exist together in the same setting, with the largest examples reflecting the most common/formative wind azimuths. In cases where wind azimuth is not dominated by a single

  5. 76 FR 67558 - Proposed Information Collection (Application for Work-Study Allowance) Activity: Comment Request

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-11-01

    ... (Application for Work-Study Allowance) Activity: Comment Request AGENCY: Veterans Benefits Administration... claimant's eligibility for work-study benefits. DATES: Written comments and recommendations on the proposed... use of other forms of information technology. Titles: a. Application for Work-Study Allowance, VA Form...

  6. Moderately high frequency ventilation with a conventional ventilator allows reduction of tidal volume without increasing mean airway pressure.

    PubMed

    Cordioli, Ricardo Luiz; Park, Marcelo; Costa, Eduardo Leite Vieira; Gomes, Susimeire; Brochard, Laurent; Amato, Marcelo Britto Passos; Azevedo, Luciano Cesar Pontes

    2014-12-01

    The aim of this study was to explore if positive-pressure ventilation delivered by a conventional ICU ventilator at a moderately high frequency (HFPPV) allows a safe reduction of tidal volume (V T) below 6 mL/kg in a porcine model of severe acute respiratory distress syndrome (ARDS) and at a lower mean airway pressure than high-frequency oscillatory ventilation (HFOV). This is a prospective study. In eight pigs (median weight 34 [29,36] kg), ARDS was induced by pulmonary lavage and injurious ventilation. The animals were ventilated with a randomized sequence of respiratory rates: 30, 60, 90, 120, 150, followed by HFOV at 5 Hz. At each step, V T was adjusted to allow partial pressure of arterial carbon dioxide (PaCO2) to stabilize between 57 and 63 mmHg. Data are shown as median [P25th,P75th]. After lung injury, the PaO2/FiO2 (P/F) ratio was 92 [63,118] mmHg, pulmonary shunt 26 [17,31]%, and static compliance 11 [8,14] mL/cmH2O. Positive end-expiratory pressure (PEEP) was 14 [10,17] cmH2O. At 30 breaths/min, V T was higher than 6 (7.5 [6.8,10.2]) mL/kg, but at all higher frequencies, V T could be reduced and PaCO2 maintained, leading to reductions in plateau pressures and driving pressures. For frequencies of 60 to 150/min, V T progressively fell from 5.2 [5.1,5.9] to 3.8 [3.7,4.2] mL/kg (p < 0.001). There were no detrimental effects in terms of lung mechanics, auto-PEEP generation, hemodynamics, or gas exchange. Mean airway pressure was maintained constant and was increased only during HFOV. During protective mechanical ventilation, HFPPV delivered by a conventional ventilator in a severe ARDS swine model safely allows further tidal volume reductions. This strategy also allowed decreasing airway pressures while maintaining stable PaCO2 levels.

  7. Impact of work pressure, work stress and work-family conflict on firefighter burnout.

    PubMed

    Smith, Todd D; DeJoy, David M; Dyal, Mari-Amanda Aimee; Huang, Gaojian

    2017-10-25

    Little research has explored burnout and its causes in the American fire service. Data were collected from career firefighters in the southeastern United States (n = 208) to explore these relationships. A hierarchical regression model was tested to examine predictors of burnout including sociodemographic characteristics (model 1), work pressure (model 2), work stress and work-family conflict (model 3) and interaction terms (model 4). The main findings suggest that perceived work stress and work-family conflict emerged as the significant predictors of burnout (both p < .001). Interventions and programs aimed at these predictors could potentially curtail burnout among firefighters.

  8. Blood pressure variations during a working day at age 28: effects of different types of work and blood pressure level at age 18.

    PubMed

    Theorell, T; Knox, S; Svensson, J; Waller, D

    1985-01-01

    During an ordinary work day blood pressure was self-monitored once every hour in two samples of asymptomatic nonmedicating 28-year-old men. They were selected on the basis of previous compulsory blood pressure recordings made at the age of 18 when they had been drafted for military service. Subjects in the "original hypertensive sample" with "strain" occupations (hectic and uncontrollable, such as waiter, driver and cook) had more marked elevations of systolic blood pressure during work hours than other subjects.

  9. Temperature and Pressure Sensors Based on Spin-Allowed Broadband Luminescence of Doped Orthorhombic Perovskite Structures

    NASA Technical Reports Server (NTRS)

    Eldridge, Jeffrey I. (Inventor); Chambers, Matthew D. (Inventor)

    2014-01-01

    Systems and methods that are capable of measuring pressure or temperature based on luminescence are discussed herein. These systems and methods are based on spin-allowed broadband luminescence of sensors with orthorhombic perovskite structures of rare earth aluminates doped with chromium or similar transition metals, such as chromium-doped gadolinium aluminate. Luminescence from these sensors can be measured to determine at least one of temperature or pressure, based on either the intense luminescence of these sensors, even at high temperatures, or low temperature techniques discussed herein.

  10. Effect of overtime work on 24-hour ambulatory blood pressure.

    PubMed

    Hayashi, T; Kobayashi, Y; Yamaoka, K; Yano, E

    1996-10-01

    Recently, the adverse effects of long working hours on the cardiovascular systems of workers in Japan, including "Karoshi" (death from overwork), have been the focus of social concern. However, conventional methods of health checkups are often unable to detect the early signs of such adverse effects. To evaluate the influence of overtime work on the cardiovascular system, we compared 24-hour blood pressure measurements among several groups of male white-collar workers. As a result, for those with normal blood pressure and those with mild hypertension, the 24-hour average blood pressure of the overtime groups was higher than that of the control groups; for those who periodically did overtime work, the 24-hour average blood pressure and heart rate during the busy period increased. These results indicate that the burden on the cardiovascular system of white-collar workers increases with overtime work.

  11. 77 FR 2351 - Agency Information Collection (Application for Work-Study Allowance): Activity Under OMB Review

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-01-17

    ... (Application for Work-Study Allowance): Activity Under OMB Review AGENCY: Veterans Benefits Administration... ``OMB Control No. 2900-0209.'' SUPPLEMENTARY INFORMATION: Titles a. Application for Work-Study Allowance, VA Form 22-8691. b. Student Work-Study Agreement (Advance Payment), VA Form 22-8692. c. Extended...

  12. Job-related resources and the pressures of working life.

    PubMed

    Schieman, Scott

    2013-03-01

    Data from a 2011 representative sample of Canadian workers are used to test the resource versus the stress of higher status hypotheses. Drawing on the Job Demands-Resources model (JD-R), the resource hypothesis predicts that job-related resources reduce job pressure. The stress of higher status hypothesis predicts that job-related resources increase job pressure. Findings tend to favor the resource hypothesis for job autonomy and schedule control, while supporting the stress of higher status for job authority and challenging work. These findings help elaborate on the "resource" concept in the JD-R model and identify unique ways that such resources might contribute to the pressures of working life. Copyright © 2012 Elsevier Inc. All rights reserved.

  13. Compressed-air work is entering the field of high pressures.

    PubMed

    Le Péchon, J Cl; Gourdon, G

    2010-01-01

    Since 1850, compressed-air work has been used to prevent shafts or tunnels under construction from flooding. Until the 1980s, workers were digging in compressed-air environments. Since the introduction of tunnel boring machines (TBMs), very little digging under pressure is needed. However, the wearing out of cutter-head tools requires inspection and repair. Compressed-air workers enter the pressurized working chamber only occasionally to perform such repairs. Pressures between 3.5 and 4.5 bar, that stand outside a reasonable range for air breathing, were reached by 2002. Offshore deep diving technology had to be adapted to TBM work. Several sites have used mixed gases: in Japan for deep shaft sinking (4.8 bar), in The Netherlands at Western Scheldt Tunnels (6.9 bar), in Russia for St. Petersburg Metro (5.8 bar) and in the United States at Seattle (5.8 bar). Several tunnel projects are in progress that may involve higher pressures: Hallandsås (Sweden) interventions in heliox saturation up to 13 bar, and Lake Mead (U.S.) interventions to about 12 bar (2010). Research on TBMs and grouting technologies tries to reduce the requirements for hyperbaric works. Adapted international rules, expertise and services for saturation work, shuttles and trained personnel matching industrial requirements are the challenges.

  14. Job strain and ambulatory work blood pressure in healthy young men and women.

    PubMed

    Light, K C; Turner, J R; Hinderliter, A L

    1992-08-01

    The effect of high job strain (defined as high psychological demands plus low decision latitude at work) on blood pressure was determined in 129 healthy, nonhypertensive men (n = 65) and women (n = 64). Blood pressure measures included mean screening levels obtained in a clinical environment, mean ambulatory levels from one 8-hour workday, and the change in levels from screening to mean work levels. In male workers, men with high and low job strain showed similar blood pressures at screening, but men with high job strain showed greater increases from screening to work, resulting in higher mean work blood pressure. Occupational status was unrelated to job strain or blood pressure in men. In female workers, women with high and low job strain did not differ in any measure of blood pressure; however, there were trends for higher occupational status and greater skill discretion to be associated with higher blood pressure responses at work in women.

  15. Perceived unfairness at work, social and personal resources, and resting blood pressure.

    PubMed

    Ford, Michael T

    2014-02-01

    By drawing from theoretical perspectives suggesting that unfair conditions threaten fundamental psychological needs, perceived unfairness at work was proposed and tested as a predictor of resting blood pressure. As part of the Midlife Development in the United States Biomarkers project, participants completed questionnaires measuring perceived unfairness, self-esteem and coworker support. Resting blood pressure readings were also recorded as part of a larger physical examination. Results indicate that perceived unfairness at work was associated with higher resting diastolic and systolic blood pressure. Perceived unfairness was most strongly related to diastolic and systolic blood pressure among women with low levels of coworker support. Contrary to predictions, self-esteem did not moderate the association between perceived unfairness and blood pressure. These results suggest that high blood pressure may be a mechanism linking unfairness to negative health outcomes and point to coworker support as a moderator of the perceived unfairness-blood pressure relationship among women. Further research is needed exploring the mediating mechanisms linking unfair treatment at work to blood pressure and health. Copyright © 2013 John Wiley & Sons, Ltd.

  16. The Loss Spiral of Work Pressure, Work-Home Interference and Exhaustion: Reciprocal Relations in a Three-Wave Study

    ERIC Educational Resources Information Center

    Demerouti, Evangelia; Bakker, Arnold B.; Bulters, Annemieke J.

    2004-01-01

    This study tested the "loss spiral" hypothesis of work-home interference (WHI). Accordingly, work pressure was expected to lead to WHI and exhaustion, and, vice versa, exhaustion was expected to result in more WHI and work pressure over time. Results of SEM-analyses using three waves of data obtained from 335 employees of an employment agency…

  17. Linking Parents' Work Pressure and Adolescents' Well-Being: Insights into Dynamics in Dual-Earner Families.

    ERIC Educational Resources Information Center

    Crouter, Ann C.; Bumpus, Matthew F.; Maguire, Mary C.; McHale, Susan M.

    1999-01-01

    Examined connections between parents' work pressure and adolescent adjustment in 190 dual-earner families. Found that effects of work pressure on adolescent well-being were mediated by parental role overload and parent-adolescent conflict. Fathers' work pressure predicted both parents' feelings of role overload. Mothers' work pressure predicted…

  18. A Modified Triples Algorithm for Flush Air Data Systems that Allows a Variety of Pressure Port Configurations

    NASA Technical Reports Server (NTRS)

    Millman, Daniel R.

    2017-01-01

    Air Data Systems (FADS) are becoming more prevalent on re-entry vehicles, as evi- denced by the Mars Science Laboratory and the Orion Multipurpose Crew Vehicle. A FADS consists of flush-mounted pressure transducers located at various locations on the fore-body of a flight vehicle or the heat shield of a re-entry capsule. A pressure model converts the pressure readings into useful air data quantities. Two algorithms for converting pressure readings to air data have become predominant- the iterative Least Squares State Estimator (LSSE) and the Triples Algorithm. What follows herein is a new algorithm that takes advantage of the best features of both the Triples Algorithm and the LSSE. This approach employs the potential flow model and strategic differencing of the Triples Algorithm to obtain the defective flight angles; however, the requirements on port placement are far less restrictive, allowing for configurations that are considered optimal for a FADS.

  19. Intramyocardial pressure gradients in working and nonworking isolated cat hearts.

    PubMed

    Mihailescu, L S; Abel, F L

    1994-03-01

    This study presents an improved method for the measurement of intramyocardial pressure (IMP) using the servo-nulling mechanism. Glass micropipettes (20-24 microns OD) were used as transducers, coated to increase their mechanical resistance to breakage, and placed inside the left ventricular wall with a micropipette holder and manipulator. IMP was measured at the base of the left ventricle in working and nonworking isolated cat hearts that were perfused with Krebs-Henseleit buffer. In working hearts a transmural gradient of systolic IMP oriented from endocardium toward the epicardium was found; the endocardial values for systolic IMP were slightly higher than systolic left ventricular pressure (LVP), by 11-18%. Increases in afterload induced increases in IMP, without changing the systolic IMP-to-LVP ratio. In nonworking hearts with drained left ventricles, the systolic transmural gradient for IMP described for working hearts persisted, but at lower values, and was directly dependent on coronary perfusion pressure. Systolic IMP-to-LVP ratios were always > 1. The diastolic IMP of both working and nonworking hearts exhibited irregular transmural gradients. Our results support the view that generated systolic IMP is largely independent of LVP development.

  20. Oncologist burnout and compassion fatigue: investigating time pressure at work as a predictor and the mediating role of work-family conflict.

    PubMed

    Kleiner, Sibyl; Wallace, Jean E

    2017-09-11

    Oncologists are at high risk of poor mental health. Prior research has focused on burnout, and has identified heavy workload as a key predictor. Compassion fatigue among physicians has generally received less attention, although medical specialties such as oncology may be especially at risk of compassion fatigue. We contribute to research by identifying predictors of both burnout and compassion fatigue among oncologists. In doing so, we distinguish between quantitative workload (e.g., work hours) and subjective work pressure, and test whether work-family conflict mediates the relationships between work pressure and burnout or compassion fatigue. In a cross-sectional study, oncologists from across Canada (n = 312) completed questionnaires assessing burnout, compassion fatigue, workload, time pressure at work, work-family conflict, and other personal, family, and occupational characteristics. Analyses use Ordinary Least Squares regression. Subjective time pressure at work is a key predictor of both burnout and compassion fatigue. Our results also show that work-family conflict fully mediates these relationships. Overall, the models explain more of the variation in burnout as compared to compassion fatigue. Our study highlights the need to consider oncologists' subjective time pressure, in addition to quantitative workload, in interventions to improve mental health. The findings also highlight a need to better understand additional predictors of compassion fatigue.

  1. How Ministers Understand and Address Emotional and Sexual Pressures in Ministry Work

    ERIC Educational Resources Information Center

    Reid, Genise Aria

    2012-01-01

    This study explored the perceptions of ministers in regard to how they understand and address emotional and sexual pressures encountered in ministry work. The research was guided by four questions: How do practicing ministers in the Church of Antioch describe and understand pressures in their work settings that they see as emotional or sexual in…

  2. On designing low pressure loss working spaces for a planar Stirling micromachine

    NASA Astrophysics Data System (ADS)

    Hachey, M.-A.; Léveillé, É.; Fréchette, L. G.; Formosa, F.

    2015-12-01

    In this paper, research was undertaken with the objective to design low pressure loss working spaces for a Stirling cycle micro heat engine operating from low temperature waste heat. This planar free-piston heat engine is anticipated to operate at the kHz level with mm3 displacement. Given the resonant nature of the free-piston configuration, the complexity of its working gas’ flow geometry and its projected high operating frequency, flow analysis is relatively complex. Design considerations were thus based on fast prototyping and experimentation. Results show that geometrical features, such as a sharp 90° corner between the regenerator and working spaces, are strong contributors to pressure losses. This research culminated into a promising revised working space configuration for engine start-up, as it considerably reduced total pressure losses, more than 80% at Re = 700, from the original design.

  3. Wavenumber-frequency Spectra of Pressure Fluctuations Measured via Fast Response Pressure Sensitive Paint

    NASA Technical Reports Server (NTRS)

    Panda, J.; Roozeboom, N. H.; Ross, J. C.

    2016-01-01

    The recent advancement in fast-response Pressure-Sensitive Paint (PSP) allows time-resolved measurements of unsteady pressure fluctuations from a dense grid of spatial points on a wind tunnel model. This capability allows for direct calculations of the wavenumber-frequency (k-?) spectrum of pressure fluctuations. Such data, useful for the vibro-acoustics analysis of aerospace vehicles, are difficult to obtain otherwise. For the present work, time histories of pressure fluctuations on a flat plate subjected to vortex shedding from a rectangular bluff-body were measured using PSP. The light intensity levels in the photographic images were then converted to instantaneous pressure histories by applying calibration constants, which were calculated from a few dynamic pressure sensors placed at selective points on the plate. Fourier transform of the time-histories from a large number of spatial points provided k-? spectra for pressure fluctuations. The data provides first glimpse into the possibility of creating detailed forcing functions for vibro-acoustics analysis of aerospace vehicles, albeit for a limited frequency range.

  4. Influence of computer work under time pressure on cardiac activity.

    PubMed

    Shi, Ping; Hu, Sijung; Yu, Hongliu

    2015-03-01

    Computer users are often under stress when required to complete computer work within a required time. Work stress has repeatedly been associated with an increased risk for cardiovascular disease. The present study examined the effects of time pressure workload during computer tasks on cardiac activity in 20 healthy subjects. Heart rate, time domain and frequency domain indices of heart rate variability (HRV) and Poincaré plot parameters were compared among five computer tasks and two rest periods. Faster heart rate and decreased standard deviation of R-R interval were noted in response to computer tasks under time pressure. The Poincaré plot parameters showed significant differences between different levels of time pressure workload during computer tasks, and between computer tasks and the rest periods. In contrast, no significant differences were identified for the frequency domain indices of HRV. The results suggest that the quantitative Poincaré plot analysis used in this study was able to reveal the intrinsic nonlinear nature of the autonomically regulated cardiac rhythm. Specifically, heightened vagal tone occurred during the relaxation computer tasks without time pressure. In contrast, the stressful computer tasks with added time pressure stimulated cardiac sympathetic activity. Copyright © 2015 Elsevier Ltd. All rights reserved.

  5. Leadership and Presenteeism among Scientific Staff: The Role of Accumulation of Work and Time Pressure

    PubMed Central

    Dietz, Carolin; Scheel, Tabea

    2017-01-01

    The present study examines the joint roles of leadership and stressors for presenteeism of scientific staff. Leaders may have an impact on employees' health, both directly through interpersonal interactions and by shaping their working conditions. In the field of science, this impact could be special because of the mentoring relationships between the employees (e.g., PhD students) and their supervisors (e.g., professors). Based on the job demands-resources framework (JD-R), we hypothesized that the pressure to be present at the workplace induced by supervisors (supervisorial pressure) is directly related to employees' presenteeism as well as indirectly via perceptions of time pressure. The conservation of resources theory (COR) states that resource loss resulting from having to deal with job demands weakens the resource pool and therefore the capacity to deal with other job demands. Thus, we hypothesized that accumulation of work moderates the relationship between supervisorial pressure and time pressure, such that the relationship is stronger when accumulation of work is high compared to if accumulation of work is low. Cross-sectional data were obtained from 212 PhD students and postdocs of 30 scientific institutions in Germany. Analysis was performed using the SPSS macro PROCESS (Hayes, 2013). Supervisorial pressure was directly associated with higher presenteeism of employees and indirectly through increased time pressure. Moreover, supervisorial pressure and accumulation of work interacted to predict time pressure, but in an unexpected way. The positive relationship between supervisorial pressure and time pressure is stronger when accumulation is low compared to if accumulation of work is high. It seems possible that job stressors do not accumulate but substitute each other. Threshold models might explain the findings. Moreover, specific patterns of interacting job demands for scientific staff should be considered in absence management. PMID:29123497

  6. [The effect of work-related stress on the occurrence of increased blood pressure].

    PubMed

    Budaj, A; Cybulski, J; Kułakowski, P; Makowska, E; Rezler, J; Lange, J; Gorzkowska, J; Abramowski, S

    In 546 officials the arterial blood pressure was measured twice at the beginning and at the end of a working day, filling also an inquiry form. As hypertension systolic BP over 160 mm Hg (21.3 kPa) or more, and diastolic BP 96 mm Hg (12.7 kPa) or more were accepted. In 90 subjects (16.5%) above normal pressure values were found. Hypertension had been diagnosed previously in 50 subjects in this group (55.5%) but only 13 of them (26%) were treated systematically. Excessive stress of work was complained of by 62.6% of the subjects. Increased blood pressure was found significantly more frequently in the group perceiving excessive stress of work (19.9%) as compared to those not experiencing this stress (10.8%, p less than 0.1). In the group in managerial posts these proportions were 24.8% and 14.4% respectively (p less than 0.1). Blood pressure rise to abnormal levels during the working day occurred also significantly more frequently in the group experiencing it this was noted only in 1.6% of cases (p less than 0.5). The knowledge of own hypertension was very low in this group. These results indicate the necessity of increasing prophylactic measures in the form of greater frequency of control measurements of the blood pressure, better health education, and limitation of stress situations in working environment.

  7. Diving under a microscope--a new simple and versatile in vitro diving device for fluorescence and confocal microscopy allowing the controls of hydrostatic pressure, gas pressures, and kinetics of gas saturation.

    PubMed

    Wang, Qiong; Belhomme, Marc; Guerrero, François; Mazur, Aleksandra; Lambrechts, Kate; Theron, Michaël

    2013-06-01

    How underwater diving effects the function of the arterial wall and the activities of endothelial cells is the focus of recent studies on decompression sickness. Here we describe an in vitro diving system constructed to achieve real-time monitoring of cell activity during simulated dives under fluorescent microscopy and confocal microscopy. A 1-mL chamber with sapphire windows on both sides and located on the stage of an inverted microscope was built to allow in vitro diving simulation of isolated cells or arteries in which activities during diving are monitored in real-time via fluorescent microscopy and confocal microscopy. Speed of compression and decompression can range from 20 to 2000 kPa/min, allowing systemic pressure to range up to 6500 kPa. Diving temperature is controlled at 37°C. During air dive simulation oxygen partial pressure is optically monitored. Perfusion speed can range from 0.05 to 10 mL/min. The system can support physiological viability of in vitro samples for real-time monitoring of cellular activity during diving. It allows regulations of pressure, speeds of compression and decompression, temperature, gas saturation, and perfusion speed. It will be a valuable tool for hyperbaric research.

  8. A path analysis model for explaining unsafe behavior in workplaces: the effect of perceived work pressure.

    PubMed

    Ghasemi, Fakhradin; Kalatpour, Omid; Moghimbeigi, Abbas; Mohhamadfam, Iraj

    2018-06-01

    Unsafe behavior is closely related to occupational accidents. Work pressure is one the main factors affecting employees' behavior. The aim of the present study was to provide a path analysis model for explaining how work pressure affects safety behavior. Using a self-administered questionnaire, six variables supposed to affect safety employees' behavior were measured. The path analysis model was constructed based on several hypotheses. The goodness of fit of the model was assessed using both absolute and comparative fit indices. Work pressure was determined not to influence safety behavior directly. However, it negatively influenced other variables. Group attitude and personal attitude toward safety were the main factors mediating the effect of work pressure on safety behavior. Among the variables investigated in the present study, group attitude, personal attitude and work pressure had the strongest effects on safety behavior. Managers should consider that in order to improve employees' safety behavior, work pressure should be reduced to a reasonable level, and concurrently a supportive environment, which ensures a positive group attitude toward safety, should be provided. Replication of the study is recommended.

  9. Working under pressure: a pilot study of nurse work in a postoperative setting.

    PubMed

    Willis, Karen; Brown, Claire R; Sahlin, Ingrid; Svensson, Björn; Arnetz, Bengt B; Arnetz, Judith E

    2005-01-01

    Postoperative services provide an excellent setting to study nursing work due to the patients' needing highly technical, yet highly comforting, care. The current study examined nursing work in postoperative services in an attempt to discern how nursing work is structured. Observations of nursing interactions in a 14-bed postoperative unit of a large Swedish university hospital found that nursing work in this setting is highly intensive and multidimensional. The need to provide nursing interactions that are caring and respectful of patients, while at the same time ensuring a high level of technical capacity, was obvious throughout all stages of patient stays in this unit. Furthermore, although each interaction is necessarily time-limited there is a caring relationship sustained with each patient. There is a pattern of caring that emerges that can be encapsulated as a "contingent routine." Nursing work cannot be broken down into "dimensions of caring." The work is high-pressure and involves, by necessity, multitasking. There are many dimensions of nursing care, but, usually, these are supplied simultaneously.

  10. The curvilinear relationship between work pressure and momentary task performance: the role of state and trait core self-evaluations.

    PubMed

    Hofmans, Joeri; Debusscher, Jonas; Dóci, Edina; Spanouli, Andromachi; De Fruyt, Filip

    2015-01-01

    Whereas several studies have demonstrated that core self-evaluations (CSE)-or one's appraisals about one's own self-worth, capabilities, and competences-relate to job outcomes, less is known about the mechanisms underlying these relationships. In the present study, we address this issue by examining the role of within- and between-person variation in CSE in the relationship between work pressure and task performance. We hypothesized that (a) work pressure relates to task performance in a curvilinear way, (b) state CSE mediates the curvilinear relationship between work pressure and task performance, and (c) the relationship between work pressure and state CSE is moderated by trait CSE. Our hypotheses were tested via a 10-day daily diary study with 55 employees in which trait CSE was measured at baseline, while work pressure, task performance, and state CSE were assessed on a daily basis. Bayesian multilevel path analysis showed that work pressure affects task performance via state CSE, with state CSE increasing as long as the employee feels that (s)he is able to handle the work pressure, while it decreases when the level of work pressure exceeds the employees' coping abilities. Moreover, we found that for people low on trait CSE, the depleting effect of work pressure via state CSE happens for low levels of work pressure, while for people high in trait CSE the depleting effect is located at high levels of work pressure. Together, our findings suggest that the impact of work pressure on task performance is driven by a complex interplay of between- and within-person differences in CSE.

  11. The Effect of Pressure on High- and Low-Working-Memory Students: An Elaboration of the Choking under Pressure Hypothesis

    ERIC Educational Resources Information Center

    Wang, Zuowei; Shah, Priti

    2014-01-01

    Sample: Fifty-three third and fourth graders from China participated in this study. Method: Participants' working memory (WM) was assessed by the Automated Operation Span task. Then, they solved mental addition problems of different types under low- and high-pressure conditions. Performance was analysed as a function of pressure condition, working…

  12. The curvilinear relationship between work pressure and momentary task performance: the role of state and trait core self-evaluations

    PubMed Central

    Hofmans, Joeri; Debusscher, Jonas; Dóci, Edina; Spanouli, Andromachi; De Fruyt, Filip

    2015-01-01

    Whereas several studies have demonstrated that core self-evaluations (CSE)–or one’s appraisals about one’s own self-worth, capabilities, and competences–relate to job outcomes, less is known about the mechanisms underlying these relationships. In the present study, we address this issue by examining the role of within- and between-person variation in CSE in the relationship between work pressure and task performance. We hypothesized that (a) work pressure relates to task performance in a curvilinear way, (b) state CSE mediates the curvilinear relationship between work pressure and task performance, and (c) the relationship between work pressure and state CSE is moderated by trait CSE. Our hypotheses were tested via a 10-day daily diary study with 55 employees in which trait CSE was measured at baseline, while work pressure, task performance, and state CSE were assessed on a daily basis. Bayesian multilevel path analysis showed that work pressure affects task performance via state CSE, with state CSE increasing as long as the employee feels that (s)he is able to handle the work pressure, while it decreases when the level of work pressure exceeds the employees’ coping abilities. Moreover, we found that for people low on trait CSE, the depleting effect of work pressure via state CSE happens for low levels of work pressure, while for people high in trait CSE the depleting effect is located at high levels of work pressure. Together, our findings suggest that the impact of work pressure on task performance is driven by a complex interplay of between- and within-person differences in CSE. PMID:26579053

  13. Non-invasive pressure difference estimation from PC-MRI using the work-energy equation

    PubMed Central

    Donati, Fabrizio; Figueroa, C. Alberto; Smith, Nicolas P.; Lamata, Pablo; Nordsletten, David A.

    2015-01-01

    Pressure difference is an accepted clinical biomarker for cardiovascular disease conditions such as aortic coarctation. Currently, measurements of pressure differences in the clinic rely on invasive techniques (catheterization), prompting development of non-invasive estimates based on blood flow. In this work, we propose a non-invasive estimation procedure deriving pressure difference from the work-energy equation for a Newtonian fluid. Spatial and temporal convergence is demonstrated on in silico Phase Contrast Magnetic Resonance Image (PC-MRI) phantoms with steady and transient flow fields. The method is also tested on an image dataset generated in silico from a 3D patient-specific Computational Fluid Dynamics (CFD) simulation and finally evaluated on a cohort of 9 subjects. The performance is compared to existing approaches based on steady and unsteady Bernoulli formulations as well as the pressure Poisson equation. The new technique shows good accuracy, robustness to noise, and robustness to the image segmentation process, illustrating the potential of this approach for non-invasive pressure difference estimation. PMID:26409245

  14. Optimizing working space in porcine laparoscopy: CT measurement of the effects of intra-abdominal pressure.

    PubMed

    Vlot, John; Wijnen, Rene; Stolker, Robert Jan; Bax, Klaas

    2013-05-01

    Several factors may affect volume and dimensions of the working space in laparoscopic surgery. The precise impact of these factors has not been well studied. In a porcine model, we used computed tomographic (CT) scanning for measuring working space volume and distances. In a first series of experiments, we studied the relationship between intra-abdominal pressure (IAP) and working space. Eleven 20 kg pigs were studied under standardized anesthesia and volume-controlled ventilation. Cardiorespiratory parameters were monitored continuously, and blood gas samples were taken at different IAP levels. Respiratory rate was increased when ETCO₂ exceeded 7 kPa. Breath-hold CT scans were made at IAP levels of 0, 5, 10, and 15 mmHg. Insufflator volumes were compared to CT-measured volumes. Maximum dimensions of pneumoperitoneum were measured on reconstructed CT images. Respiratory rate had to be increased in three animals. Mild hypercapnia and acidosis occurred at 15 mmHg IAP. Peak inspiratory pressure rose significantly at 10 and 15 mmHg. CT-measured volume increased relatively by 93 % from 5 to 10 mmHg IAP and by 19 % from 10 to 15 mmHg IAP. Comparing CT volumes to insufflator volumes gave a bias of 76 mL. The limits of agreement were -0.31 to +0.47, a range of 790 mL. The internal anteroposterior diameter increased by 18 % by increasing IAP from 5 to 10 mmHg and by 5 % by increasing IAP from 10 to 15 mmHg. At 15 mmHg, the total relative increase of the pubis-diaphragm distance was only 6 %. Abdominal width did not increase. CT allows for precise calculation of the actual CO₂ pneumoperitoneum volume, whereas the volume of CO₂ released by the insufflator does not. Increasing IAP up to 10 mmHg achieved most gain in volume and in internal anteroposterior diameter. At an IAP of 10 mmHg, higher peak inspiratory pressure was significantly elevated.

  15. How Work Affects Divorce: The Mediating Role of Financial and Time Pressures

    ERIC Educational Resources Information Center

    Poortman, Anne-Rigt

    2005-01-01

    This study examines whether the financial and time pressures associated with spouses' working lives play a role in the relation between work and divorce during the first years of marriage. Using retrospective data from the Netherlands, the results show that divorce is more likely when the husband works on average fewer hours and the wife more…

  16. 46 CFR 54.25-5 - Corrosion allowance.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 2 2010-10-01 2010-10-01 false Corrosion allowance. 54.25-5 Section 54.25-5 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING PRESSURE VESSELS Construction With Carbon, Alloy, and Heat Treated Steels § 54.25-5 Corrosion allowance. The corrosion allowance...

  17. 46 CFR 54.25-5 - Corrosion allowance.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 2 2011-10-01 2011-10-01 false Corrosion allowance. 54.25-5 Section 54.25-5 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING PRESSURE VESSELS Construction With Carbon, Alloy, and Heat Treated Steels § 54.25-5 Corrosion allowance. The corrosion allowance...

  18. 46 CFR 54.25-5 - Corrosion allowance.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 2 2012-10-01 2012-10-01 false Corrosion allowance. 54.25-5 Section 54.25-5 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING PRESSURE VESSELS Construction With Carbon, Alloy, and Heat Treated Steels § 54.25-5 Corrosion allowance. The corrosion allowance...

  19. 46 CFR 54.25-5 - Corrosion allowance.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 2 2013-10-01 2013-10-01 false Corrosion allowance. 54.25-5 Section 54.25-5 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING PRESSURE VESSELS Construction With Carbon, Alloy, and Heat Treated Steels § 54.25-5 Corrosion allowance. The corrosion allowance...

  20. 46 CFR 54.25-5 - Corrosion allowance.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 2 2014-10-01 2014-10-01 false Corrosion allowance. 54.25-5 Section 54.25-5 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING PRESSURE VESSELS Construction With Carbon, Alloy, and Heat Treated Steels § 54.25-5 Corrosion allowance. The corrosion allowance...

  1. 76 FR 1504 - Pipeline Safety: Establishing Maximum Allowable Operating Pressure or Maximum Operating Pressure...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-01-10

    ... profile that is dependent upon the pipelines attributes, its geographical location, design, operating... type of threats posed by the pipeline segment, including consideration of the age, design, pipe... calculation. There are several methods available for establishing MAOP or MOP. A hydrostatic pressure test...

  2. Highly ionized physical vapor deposition plasma source working at very low pressure

    NASA Astrophysics Data System (ADS)

    Stranak, V.; Herrendorf, A.-P.; Drache, S.; Cada, M.; Hubicka, Z.; Tichy, M.; Hippler, R.

    2012-04-01

    Highly ionized discharge for physical vapor deposition at very low pressure is presented in the paper. The discharge is generated by electron cyclotron wave resonance (ECWR) which assists with ignition of high power impulse magnetron sputtering (HiPIMS) discharge. The magnetron gun (with Ti target) was built into the single-turn coil RF electrode of the ECWR facility. ECWR assistance provides pre-ionization effect which allows significant reduction of pressure during HiPIMS operation down to p = 0.05 Pa; this is nearly more than an order of magnitude lower than at typical pressure ranges of HiPIMS discharges. We can confirm that nearly all sputtered particles are ionized (only Ti+ and Ti++ peaks are observed in the mass scan spectra). This corresponds well with high plasma density ne ˜ 1018 m-3, measured during the HiPIMS pulse.

  3. The influence of abdominal obesity and chronic work stress on ambulatory blood pressure in men and women.

    PubMed

    Steptoe, A; Cropley, M; Griffith, J; Joekes, K

    1999-11-01

    To assess the influence of abdominal obesity and work stress (operationalised as low control over work) on ambulatory blood pressure on a working day and evening. 156 school teachers (58 men and 98 women) carried out ambulatory blood pressure and heart rate monitoring on a work day and evening. Cardiovascular activity was also measured under baseline conditions on another occasion, when body weight, height, waist and hip circumference were assessed. Perceived control over work was assessed by questionnaire, along with mental health, anger expression and social support. 126 participants repeated the protocol after 12 months. Waist/hip ratio was used as the index of abdominal obesity. Baseline blood pressure was positively associated with waist/hip ratio in men, but ambulatory blood pressure and heart rate were not independently related to waist/hip ratio or job control. However, blood pressure and heart rate recorded during the working day and evening were elevated in men with high waist/hip ratio who experienced low job control, independently of age and body weight. Effects for diastolic blood pressure and heart rate were replicated after 12 months. Body mass index was not related to blood pressure or heart rate during the day or evening after adjustment for age and waist circumference. Low job control was associated with poor psychological well-being, negative mood and lack of social support. The results are consistent with the hypothesis that abdominal obesity in men is characterised by a tendency towards heightened stress-induced physiological activation, but that this tendency will only be manifest in the presence of appropriate environmental challenges such as chronic work stress.

  4. A Demands-Resources Model of Work Pressure in IT Student Task Groups

    ERIC Educational Resources Information Center

    Wilson, E. Vance; Sheetz, Steven D.

    2010-01-01

    This paper presents an initial test of the group task demands-resources (GTD-R) model of group task performance among IT students. We theorize that demands and resources in group work influence formation of perceived group work pressure (GWP) and that heightened levels of GWP inhibit group task performance. A prior study identified 11 factors…

  5. Auto-ignition of lubricating oil working at high pressures in a compressor for an air conditioner.

    PubMed

    Kim, Chul Jin; Choi, Hyo Hyun; Sohn, Chae Hoon

    2011-01-15

    Auto-ignition of lubricating oil working in a compressor for an air conditioner is studied experimentally. The adopted lubricating oil is an unknown mixture with multi-components and known to have flash point temperature of 170 °C. First, its auto-ignition temperature is measured 365 °C at atmospheric pressure. The lubricating oil works under high-pressure condition up to 30 atm and it is heated and cooled down repeatedly. Accordingly, auto-ignition temperatures or flammable limits of lubricating oil are required at high pressures with respect to fire safety. Because there is not a standard test method for the purpose, a new ignition-test method is proposed in this study and thereby, auto-ignition temperatures are measured over the pressure range below 30 atm. The measured temperatures range from 215 °C to 255 °C and they strongly depend on pressure of gas mixture consisting of oil vapor, nitrogen, and oxygen. They are close to flash point temperature and the lubricating oil can be hazardous when it works for high-pressure operating condition and abundant air flows into a compressor. Copyright © 2010 Elsevier B.V. All rights reserved.

  6. Nonlinear lymphangion pressure-volume relationship minimizes edema

    PubMed Central

    Venugopal, Arun M.; Stewart, Randolph H.; Laine, Glen A.

    2010-01-01

    Lymphangions, the segments of lymphatic vessel between two valves, contract cyclically and actively pump, analogous to cardiac ventricles. Besides having a discernable systole and diastole, lymphangions have a relatively linear end-systolic pressure-volume relationship (with slope Emax) and a nonlinear end-diastolic pressure-volume relationship (with slope Emin). To counter increased microvascular filtration (causing increased lymphatic inlet pressure), lymphangions must respond to modest increases in transmural pressure by increasing pumping. To counter venous hypertension (causing increased lymphatic inlet and outlet pressures), lymphangions must respond to potentially large increases in transmural pressure by maintaining lymph flow. We therefore hypothesized that the nonlinear lymphangion pressure-volume relationship allows transition from a transmural pressure-dependent stroke volume to a transmural pressure-independent stroke volume as transmural pressure increases. To test this hypothesis, we applied a mathematical model based on the time-varying elastance concept typically applied to ventricles (the ratio of pressure to volume cycles periodically from a minimum, Emin, to a maximum, Emax). This model predicted that lymphangions increase stroke volume and stroke work with transmural pressure if Emin < Emax at low transmural pressures, but maintain stroke volume and stroke work if Emin= Emax at higher transmural pressures. Furthermore, at higher transmural pressures, stroke work is evenly distributed among a chain of lymphangions. Model predictions were tested by comparison to previously reported data. Model predictions were consistent with reported lymphangion properties and pressure-flow relationships of entire lymphatic systems. The nonlinear lymphangion pressure-volume relationship therefore minimizes edema resulting from both increased microvascular filtration and venous hypertension. PMID:20601461

  7. Central arterial pressure assessment with intensity POF sensor

    NASA Astrophysics Data System (ADS)

    Leitão, Cátia; Gonçalves, Steve; Antunes, Paulo; Bastos, José M.; Pinto, João. L.; André, Paulo

    2015-09-01

    The central pressure monitoring is considered a new key factor in hypertension assessment and cardiovascular prevention. In this work, it is presented the central arterial systolic pressure assessment with an intensity based POF sensor. The device was tested in four subjects, and stable pulse waves were obtained, allowing the calculation of the central pressure for all the subjects. The results shown that the sensor performs reliably, being a simple and low-cost solution to the intended application.

  8. Blade Surface Pressure Distributions in a Rocket Engine Turbine: Experimental Work With On-Blade Pressure Transducers

    NASA Technical Reports Server (NTRS)

    Hudson, Susan T.; Zoladz, Thomas F.; Griffin, Lisa W.; Turner, James E. (Technical Monitor)

    2000-01-01

    Understanding the unsteady aspects of turbine rotor flowfields is critical to successful future turbine designs. A technology program was conducted at NASA's Marshall Space Flight Center to increase the understanding of unsteady environments for rocket engine turbines. The experimental program involved instrumenting turbine rotor blades with surface-mounted high frequency response pressure transducers. The turbine model was then tested to measure the unsteady pressures on the rotor blades. The data obtained from the experimental program is unique in three respects. First, much more unsteady data was obtained (several minutes per set point) than has been possible in the past. Also, two independent unsteady data acquisition systems and fundamental signal processing approaches were used. Finally, an extensive steady performance database existed for the turbine model. This allowed an evaluation of the effect of the on-blade instrumentation on the turbine's performance. This unique data set, the lessons learned for acquiring this type of data, and the improvements made to the data analysis and prediction tools will contribute to future turbine programs such as those for reusable launch vehicles.

  9. Expansion Work without the External Pressure and Thermodynamics in Terms of Quasistatic Irreversible Processes

    ERIC Educational Resources Information Center

    Schmidt-Rohr, Klaus

    2014-01-01

    We demonstrate that the formula for irreversible expansion work in most chemical thermodynamics textbooks does not apply during the expansion process. Instead of the "external pressure" P[subscript ext], the pressure P[subscript sys,mb] on the piston or other moving boundary (hence the subscript mb), which is nearly equal to the system…

  10. Stress in highly demanding IT jobs: transformational leadership moderates the impact of time pressure on exhaustion and work-life balance.

    PubMed

    Syrek, Christine J; Apostel, Ella; Antoni, Conny H

    2013-07-01

    The objective of this article is to investigate transformational leadership as a potential moderator of the negative relationship of time pressure to work-life balance and of the positive relationship between time pressure and exhaustion. Recent research regards time pressure as a challenge stressor; while being positively related to motivation and performance, time pressure also increases employee strain and decreases well-being. Building on the Job Demand-Resources model, we hypothesize that transformational leadership moderates the relationships between time pressure and both employees' exhaustion and work-life balance such that both relationships will be weaker when transformational leadership is higher. Of seven information technology organizations in Germany, 262 employees participated in the study. Established scales for time pressure, transformational leadership, work-life balance, and exhaustion were used, all showing good internal consistencies. The results support our assumptions. Specifically, we find that under high transformational leadership the impact of time pressure on exhaustion and work-life balance was less strong. The results of this study suggest that, particularly under high time pressure, transformational leadership is an important factor for both employees' work-life balance and exhaustion. PsycINFO Database Record (c) 2013 APA, all rights reserved.

  11. Acoustic emission testing of 12-nickel maraging steel pressure vessels

    NASA Technical Reports Server (NTRS)

    Dunegan, H. L.

    1973-01-01

    Acoustic emission data were obtained from three point bend fracture toughness specimens of 12-nickel maraging steel, and two pressure vessels of the same material. One of the pressure vessels contained a prefabricated flaw which was extended and sharpened by fatigue cycling. It is shown that the flawed vessel had similar characteristics to the fracture specimens, thereby allowing estimates to be made of its nearness to failure during a proof test. Both the flawed and unflawed pressure vessel survived the proof pressure and 5 cycles to the working pressure, but it was apparent from the acoustic emission response during the proof cycle and the 5 cycles to the working pressure that the flawed vessel was very near failure. The flawed vessel did not survive a second cycle to the proof pressure before failure due to flaw extension through the wall (causing a leak).

  12. Work Pressure and Safety Behaviors among Health Workers in Ghana: The Moderating Role of Management Commitment to Safety.

    PubMed

    Amponsah-Tawaih, Kwesi; Adu, Michael Appiah

    2016-12-01

    safety and healthy working environment has received numerous research attention over the years. Majority of these researches seem to have been conducted in the construction industry, with little attention in the health sector. Nonetheless, there are couple of studies conducted in Africa that suggest pressure in hospitals. Therefore the aim of the study was to examine how pressure influence safety behavior in the hospitals. With reference to the relevance of safety behavior in primary health care delivery, there was the need for the study. Data was obtained from 422 public hospital employees. Respondents were assured that all information would be kept confidential to increase the response rate and acquire more accurate information. Collection of questionnaires from participants took four weeks (20 working days), after which the data was analyzed. The result of the study showed that work pressure correlated negatively with safety behavior. General safety climate significantly correlated positively with safety behavior and negatively with work pressure, although the effect size for the latter was smaller. Hierarchical regression analysis showed management commitment to safety to moderate the relationship between work pressure and safety behavior. When employees perceive safety communication, safety systems and training to be positive, they seem to comply with safety rules and procedures than voluntarily participate in safety activities.

  13. Low-Pressure Generator Makes Cleanrooms Cleaner

    NASA Technical Reports Server (NTRS)

    2005-01-01

    Scientists at NASA's Kennedy Space Center work in cleanrooms: laboratories with high degrees of cleanliness provided by strict control of particles such as dust, lint, or human skin. They are contaminant-free facilities, where the air is repeatedly filtered, and surfaces are smooth to prevent particles from getting lodged. Technicians working in these environments wear specially designed cleanroom "bunny suits" and booties over their street clothes, as well as gloves and face masks to avoid any contamination that may be imparted from the outside world. Even normal paper is not allowed in cleanrooms, only cleanroom low-particulate paper. These are sensitive environments where precision work, like the production of silicon chips or hard disk drives, is performed. Often in cleanrooms, positive air pressure is used to force particles outside of the isolated area. The air pressure in the Kennedy cleanrooms is monitored using high-accuracy, low-differential pressure transducers that require periodic calibration. Calibration of the transducers is a tricky business. In prior years, the analysis was performed by sending the transducers to the Kennedy Standards Laboratory, where a very expensive cross-floated, labor- intensive, dead-weight test was conducted. In the early 1990s, scientists at Kennedy determined to develop a technique and find equipment to perform qualification testing on new low-differential pressure transducers in an accurate, cost-effective manner onsite, without requiring an environmentally controlled room. They decided to use the highly accurate, cost-effective Setra Model C264 as the test transducer. For qualification testing of the Setra, though, a portable, lower-cost calibrator was needed that could control the differential pressure to a high degree of resolution and transfer the accuracy of the Standards Laboratory testing to the qualification testing. The researchers decided that, to generate the low-differential pressure setpoints needed for

  14. Physical fitness and perceived psychological pressure at work: 30-year ischemic heart disease and all-cause mortality in the Copenhagen Male Study.

    PubMed

    Holtermann, Andreas; Mortensen, Ole Steen; Burr, Hermann; Søgaard, Karen; Gyntelberg, Finn; Suadicani, Poul

    2011-07-01

    Investigate if workers with low physical fitness have an increased risk of ischemic heart disease (IHD) mortality from regular psychological work pressure. Thirty-year follow-up of 5249 middle-aged men without cardiovascular disease. Men perceiving regular psychological work pressure had no higher risk of IHD mortality than those who did not. Both among men perceiving regular and rare psychological work pressure, the physically fit had a reduced risk of IHD mortality referencing men with low physical fitness. For all-cause mortality, a stronger inverse association was found among men perceiving regular compared to rare psychological pressure at work. Physical fitness is equally important for the risk of IHD mortality among men experiencing regular and rare psychological pressure at work, but stronger associated to risk of all-cause mortality among men experiencing regular psychological pressure at work.

  15. 49 CFR 230.23 - Responsibility for general construction and safe working pressure.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... MAINTENANCE STANDARDS Boilers and Appurtenances § 230.23 Responsibility for general construction and safe... construction of the steam locomotive boilers under their control. The steam locomotive owner shall establish the safe working pressure for each steam locomotive boiler, after giving full consideration to the...

  16. Hospital Magnet Status, Unit Work Environment, and Pressure Ulcers.

    PubMed

    Ma, Chenjuan; Park, Shin Hye

    2015-11-01

    To identify how organizational nursing factors at different structural levels (i.e., unit-level work environment and hospital Magnet status) are associated with hospital-acquired pressure ulcers (HAPUs) in U.S. acute care hospitals. A cross-sectional observational study used data from the National Database of Nursing Quality Indicators®. Responses from 33,845 registered nurses (RNs) were used to measure unit work environments. The unit of analysis was the nursing unit, and there were 1,381 units in 373 hospitals in the United States. Unit work environment was measured by the Practice Environment Scale of Nurse Working Index (PES-NWI). Multilevel logistic regressions were used to estimate the effects of unit work environment and hospital Magnet status on HAPUs. All models were controlled for hospital and unit characteristics when considering clustering of units within hospitals. Magnet hospital units had 21% lower odds of having an HAPU than non-Magnet hospital units (95% confidence interval [CI], 0.64-0.98). With one unit increase of the PES-NWI score, units had 29% lower odds of having an HAPU (95% CI, 0.55-0.91). When including both hospital Magnet status and unit work environment in the model, hospital Magnet status no longer had a significant effect on HAPUs (odds ratio [OR] = 0.82; 95% CI, 0.66-1.02), whereas the significant effect of unit work environment persisted (OR = 0.73; 95% CI, 0.56-0.93). Both hospital and unit environments were significantly associated with HAPUs, and the unit-level work environment can be more influential in reducing HAPUs. Investment in the nurse work environments at both the hospital level and unit level has the potential to reduce HAPUs; and additional to hospital-level initiatives (e.g., Magnet recognition program), efforts targeting on-unit work environments deserve more attention. © 2015 Sigma Theta Tau International.

  17. Alternative Work Schedules: Many Agencies Do Not Allow Employees the Full Flexibility Permitted by Law. Report to Congressional Committees.

    ERIC Educational Resources Information Center

    General Accounting Office, Washington, DC. General Government Div.

    A review was conducted of the extent to which selected federal agencies are allowing employees to use alternative work schedules (AWS) as authorized by the Federal Employees Flexible and Compressed Work Schedules Act. The statute permits, rather than requires, agencies to institute AWS programs. The study surveyed the policies and practices of 59…

  18. 49 CFR 266.11 - Allowable costs.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... TRANSPORTATION ACT § 266.11 Allowable costs. Allowable costs include only the following costs which are properly allocable to the work performed: Planning and program operation costs which are allowed under Federal... 49 Transportation 4 2010-10-01 2010-10-01 false Allowable costs. 266.11 Section 266.11...

  19. Superstrong micro-grained polycrystalline diamond compact through work hardening under high pressure

    NASA Astrophysics Data System (ADS)

    Liu, Jin; Zhan, Guodong; Wang, Qiang; Yan, Xiaozhi; Liu, Fangming; Wang, Pei; Lei, Li; Peng, Fang; Kou, Zili; He, Duanwei

    2018-02-01

    We report an approach to strengthen micro-grained polycrystalline diamond (MPD) compact through work hardening under high pressure and high temperature, in which both hardness and fracture toughness are simultaneously boosted. Micro-sized diamond powders are treated without any additives under a high pressure of 14 GPa and temperatures ranging from 1000 °C to 2000 °C. It was found that the high pressure and high temperature environments could constrain the brittle feature and cause a severe plastic deformation of starting diamond grains to form a mutual bonded diamond network. The relative density is increased with temperature to nearly fully dense at 1600 °C. The Vickers hardness of the well-prepared MPD bulks at 14 GPa and 1900 °C reaches the top limit of the single crystal diamond of 120 GPa, and the near-metallic fracture toughness of the sample is as high as 18.7 MPa m1/2.

  20. Overtime in Relation to Blood Pressure and Mood during Work, Leisure, and Night Time

    ERIC Educational Resources Information Center

    Rau, Renate; Triemer, Antje

    2004-01-01

    This study examined the association between characteristics of the workplace and overtime. A sample of 117 women and 126 men were assessed over 24 hours of a working day by means of a computerized diary and ambulant monitoring of blood pressure. Of the total sample, 178 participants had a contractual weekly working time of 40 hours. Of these, 106…

  1. Proactive life extension of pressure vessels

    NASA Astrophysics Data System (ADS)

    Mager, Lloyd

    1998-03-01

    For a company to maintain its competitive edge in today's global market every opportunity to gain an advantage must be exploited. Many companies are strategically focusing on improved utilization of existing equipment as well as regulatory compliance. Abbott Laboratories is no exception. Pharmaceutical companies such as Abbott Laboratories realize that reliability and availability of their production equipment is critical to be successful and competitive. Abbott Laboratories, like many of our competitors, is working to improve safety, minimize downtime and maximize the productivity and efficiency of key production equipment such as the pressure vessels utilized in our processes. The correct strategy in obtaining these objectives is to perform meaningful inspection with prioritization based on hazard analysis and risk. The inspection data gathered in Abbott Laboratories pressure vessel program allows informed decisions leading to improved process control. The results of the program are reduced risks to the corporation and employees when operating pressure retaining equipment. Accurate and meaningful inspection methods become the cornerstone of a program allowing proper preventative maintenance actions to occur. Successful preventative/predictive maintenance programs must utilize meaningful nondestructive evaluation techniques and inspection methods. Nondestructive examination methods require accurate useful tools that allow rapid inspection for the entire pressure vessel. Results from the examination must allow the owner to prove compliance of all applicable regulatory laws and codes. At Abbott Laboratories the use of advanced NDE techniques, primarily B-scan ultrasonics, has provided us with the proper tools allowing us to obtain our objectives. Abbott Laboratories uses B-scan ultrasonics utilizing a pulse echo pitch catch technique to provide essential data on our pressure vessels. Equipment downtime is reduced because the nondestructive examination usually takes

  2. Job strain associated with increases in ambulatory blood and pulse pressure during and after work hours among female hotel room cleaners.

    PubMed

    Feaster, Matt; Krause, Niklas

    2018-06-01

    Previously documented elevated hypertension rates among Las Vegas hotel room cleaners are hypothesized to be associated with job strain. Job strain was assessed by questionnaire. Ambulatory blood pressure (ABP) was recorded among 419 female cleaners from five hotels during 18 waking hours. Multiple linear regression models assessed associations of job strain with ABP and pulse pressure for 18-h, work hours, and after work hours. Higher job strain was associated with increased 18-h systolic ABP, after work hours systolic ABP, and ambulatory pulse pressure. Dependents at home but not social support at work attenuated effects. Among hypertensive workers, job strain effects were partially buffered by anti-hypertensive medication. High job strain is positively associated with blood pressure among female hotel workers suggesting potential for primary prevention at work. Work organizational changes, stress management, and active ABP surveillance and hypertension management should be considered for integrated intervention programs. © 2018 Wiley Periodicals, Inc.

  3. Perceived psychological pressure at work, social class, and risk of stroke: a 30-year follow-up in Copenhagen male study.

    PubMed

    Suadicani, Poul; Andersen, Lars L; Holtermann, Andreas; Mortensen, Ole S; Gyntelberg, Finn

    2011-12-01

    Investigate if the association between perceived psychological work pressure and risk of stroke is modified by socioeconomic status. Thirty-year follow-up of 4943 middle-aged men without cardiovascular disease. In the higher social classes (I, II, and III), perceived regular exposure to psychological work pressure was common and a significant predictor of stroke; almost 10% of the stroke events could be attributed to this exposure in the higher social classes; among lower social classes (IV and V), perceived psychological pressure was no predictor at all. Regular psychological work pressure is a highly prevalent and independent risk factor for stroke among men in higher social classes. In contrast, no association to stroke risk was found among low social class men.

  4. Micro packaged MEMS pressure sensor for intracranial pressure measurement

    NASA Astrophysics Data System (ADS)

    Xiong, Liu; Yan, Yao; Jiahao, Ma; Yanhang, Zhang; Qian, Wang; Zhaohua, Zhang; Tianling, Ren

    2015-06-01

    This paper presents a micro packaged MEMS pressure sensor for intracranial pressure measurement which belongs to BioMEMS. It can be used in lumbar puncture surgery to measure intracranial pressure. Miniaturization is key for lumbar puncture surgery because the sensor must be small enough to allow it be placed in the reagent chamber of the lumbar puncture needle. The size of the sensor is decided by the size of the sensor chip and package. Our sensor chip is based on silicon piezoresistive effect and the size is 400 × 400 μm2. It is much smaller than the reported polymer intracranial pressure sensors such as liquid crystal polymer sensors. In terms of package, the traditional dual in-line package obviously could not match the size need, the minimal size of recently reported MEMS-based intracranial pressure sensors after packaging is 10 × 10 mm2. In this work, we are the first to introduce a quad flat no-lead package as the package form of piezoresistive intracranial pressure sensors, the whole size of the sensor is minimized to only 3 × 3 mm2. Considering the liquid measurement environment, the sensor is gummed and waterproof performance is tested; the sensitivity of the sensor is 0.9 × 10-2 mV/kPa. Project supported by the National Natural Science Foundation of China (Nos. 61025021, 61434001), and the ‘Thousands Talents’ Program for Pioneer Researchers and Its Innovation Team, China.

  5. Lifetime shift work exposure: association with anthropometry, body composition, blood pressure, glucose and heart rate variability.

    PubMed

    Souza, Breno Bernardes; Monteze, Nayara Mussi; de Oliveira, Fernando Luiz Pereira; de Oliveira, José Magalhães; de Freitas Nascimento, Silvia; Marques do Nascimento Neto, Raimundo; Sales, Maria Lilian; Souza, Gabriela Guerra Leal

    2015-03-01

    To evaluate the association between lifetime exposure to shift work and blood pressure, fasting glucose (FG), anthropometric variables, body composition and heart rate variability (HRV). Male shift workers (N=438) were evaluated using principal component (PC) analysis. The variables used were: weight, body mass index (BMI), waist circumference (WC), neck circumference (NC), hip circumference (HC), waist-to-hip ratio (WHR), waist-to-height ratio (WHtR), body fat mass (BFKg), body fat percentage (BF%), visceral fat area (VFA), FG, systolic (SBP) and diastolic blood pressure (DBP), and HRV variables. ECG was performed, extracting heart rate (HR), root mean square of the successive differences (RMSSD), high frequency (HF), low frequency (LF) and the LF/HF ratio. Using linear regression models, the lifetime shift work exposure was associated with each PC. Five PCs were obtained, which accounted for 79.6% of the total variation of the data. PC1 (weight, BMI, WC, NC, HC, WHR, WHtR, BFKg, BF% and VFA) was designated as body obesity; PC2 (HF, RMSSD and LF) as good cardiac regulation; PC3 (SBP and DBP) as blood pressure; PC4 (LF/HF ratio and HR) as bad cardiac regulation and PC5 (WHR and FG) as insulin resistance. After age adjustment, the regression analysis showed that lifetime shift work was negatively associated with PC2 and positively associated with PC3. The association of lifetime shift work exposure with PC2 and PC3 suggests that shift work promotes unfavourable changes in autonomic cardiac control related to a decrease in parasympathetic modulation and an increase in blood pressure. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  6. Ubiquitous Working: Do Work Versus Non-work Environments Affect Decision-Making and Concentration?

    PubMed

    Burmeister, Carolin P; Moskaliuk, Johannes; Cress, Ulrike

    2018-01-01

    New communication technologies and mobile devices have enabled knowledge workers to work independently of location and in more than one fixed environment (ubiquitous working). Previous research shows that physical environments can influence cognition and work performance. We manipulated environment (i.e., a virtual office as a typical work environment compared to a virtual garden as a non-work environment ) and time pressure (i.e., inducing time pressure vs. no time pressure ) in order to investigate whether the environment influences decision-making and concentration. N = 109 students participated in this laboratory experiment. We posited (a) that a work environment would activate a work-related schema which in turn would enhance concentration performance and make decisions more risky compared to non-work environments and (b) that the environmental effect is more pronounced if time pressure is present compared to conditions where no time pressure is present. We found modest hypothesis-confirming main effects of environment on decision-making and concentration but no interaction effect with time pressure. As we used an innovative methodology that entails several limitations, future research is needed to give insights into the process and to investigate whether results hold true for all types of work settings, work demands, or work activities.

  7. 46 CFR 54.05-30 - Allowable stress values at low temperatures.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 2 2010-10-01 2010-10-01 false Allowable stress values at low temperatures. 54.05-30... PRESSURE VESSELS Toughness Tests § 54.05-30 Allowable stress values at low temperatures. (a) The Coast... nonferrous materials at low temperature for the purpose of establishing allowable stress values for service...

  8. 46 CFR 54.05-30 - Allowable stress values at low temperatures.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 2 2011-10-01 2011-10-01 false Allowable stress values at low temperatures. 54.05-30... PRESSURE VESSELS Toughness Tests § 54.05-30 Allowable stress values at low temperatures. (a) The Coast... nonferrous materials at low temperature for the purpose of establishing allowable stress values for service...

  9. 46 CFR 54.05-30 - Allowable stress values at low temperatures.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 2 2012-10-01 2012-10-01 false Allowable stress values at low temperatures. 54.05-30... PRESSURE VESSELS Toughness Tests § 54.05-30 Allowable stress values at low temperatures. (a) The Coast... nonferrous materials at low temperature for the purpose of establishing allowable stress values for service...

  10. 46 CFR 54.05-30 - Allowable stress values at low temperatures.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 2 2014-10-01 2014-10-01 false Allowable stress values at low temperatures. 54.05-30... PRESSURE VESSELS Toughness Tests § 54.05-30 Allowable stress values at low temperatures. (a) The Coast... nonferrous materials at low temperature for the purpose of establishing allowable stress values for service...

  11. 46 CFR 54.05-30 - Allowable stress values at low temperatures.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 2 2013-10-01 2013-10-01 false Allowable stress values at low temperatures. 54.05-30... PRESSURE VESSELS Toughness Tests § 54.05-30 Allowable stress values at low temperatures. (a) The Coast... nonferrous materials at low temperature for the purpose of establishing allowable stress values for service...

  12. Work-related thumb pain in physiotherapists is associated with thumb alignment during performance of PA pressures.

    PubMed

    Wajon, Anne; Ada, Louise; Refshauge, Kathryn

    2007-02-01

    Pain is common in the thumbs of physiotherapists. The purpose of this observational study was to investigate whether there is an association between the alignment of the thumb during performance of postero-anterior (PA) pressures and the presence of thumb pain. One hundred and twenty-nine physiotherapists who attended the Musculoskeletal Physiotherapy Association Conference (2003) participated. After providing a history of any work-related thumb pain, participants applied a PA pressure mimicking the technique they would use on a cervical spine, while the position of their metacarpophalangeal (MP) and interphalangeal (IP) joints was photographed. There was an association (p<0.05) between work-related thumb pain and alignment of the thumb during performance of PA pressures: participants who were able to maintain their MP and IP joints in extension were less likely to report pain. These findings serve as a guide to the safe performance of mobilization techniques, both for beginning practitioners and for experienced therapists complaining of thumb pain.

  13. Pneumatic pressure wave generator provides economical, simple testing of pressure transducers

    NASA Technical Reports Server (NTRS)

    Gaal, A. E.; Weldon, T. P.

    1967-01-01

    Testing device utilizes the change in pressure about a bias or reference pressure level produced by displacement of a center-driven piston in a closed cylinder. Closely controlled pneumatic pressure waves allow testing under dynamic conditions.

  14. Foundational Performance Analyses of Pressure Gain Combustion Thermodynamic Benefits for Gas Turbines

    NASA Technical Reports Server (NTRS)

    Paxson, Daniel E.; Kaemming, Thomas A.

    2012-01-01

    A methodology is described whereby the work extracted by a turbine exposed to the fundamentally nonuniform flowfield from a representative pressure gain combustor (PGC) may be assessed. The method uses an idealized constant volume cycle, often referred to as an Atkinson or Humphrey cycle, to model the PGC. Output from this model is used as input to a scalable turbine efficiency function (i.e., a map), which in turn allows for the calculation of useful work throughout the cycle. Integration over the entire cycle yields mass-averaged work extraction. The unsteady turbine work extraction is compared to steady work extraction calculations based on various averaging techniques for characterizing the combustor exit pressure and temperature. It is found that averages associated with momentum flux (as opposed to entropy or kinetic energy) provide the best match. This result suggests that momentum-based averaging is the most appropriate figure-of-merit to use as a PGC performance metric. Using the mass-averaged work extraction methodology, it is also found that the design turbine pressure ratio for maximum work extraction is significantly higher than that for a turbine fed by a constant pressure combustor with similar inlet conditions and equivalence ratio. Limited results are presented whereby the constant volume cycle is replaced by output from a detonation-based PGC simulation. The results in terms of averaging techniques and design pressure ratio are similar.

  15. Graphene Membranes for Atmospheric Pressure Photoelectron Spectroscopy.

    PubMed

    Weatherup, Robert S; Eren, Baran; Hao, Yibo; Bluhm, Hendrik; Salmeron, Miquel B

    2016-05-05

    Atmospheric pressure X-ray photoelectron spectroscopy (XPS) is demonstrated using single-layer graphene membranes as photoelectron-transparent barriers that sustain pressure differences in excess of 6 orders of magnitude. The graphene serves as a support for catalyst nanoparticles under atmospheric pressure reaction conditions (up to 1.5 bar), where XPS allows the oxidation state of Cu nanoparticles and gas phase species to be simultaneously probed. We thereby observe that the Cu(2+) oxidation state is stable in O2 (1 bar) but is spontaneously reduced under vacuum. We further demonstrate the detection of various gas-phase species (Ar, CO, CO2, N2, O2) in the pressure range 10-1500 mbar including species with low photoionization cross sections (He, H2). Pressure-dependent changes in the apparent binding energies of gas-phase species are observed, attributable to changes in work function of the metal-coated grids supporting the graphene. We expect atmospheric pressure XPS based on this graphene membrane approach to be a valuable tool for studying nanoparticle catalysis.

  16. 'It's a cultural expectation...' The pressure on medical trainees to work independently in clinical practice.

    PubMed

    Kennedy, Tara J T; Regehr, Glenn; Baker, G Ross; Lingard, Lorelei A

    2009-07-01

    Medical trainees demonstrate a reluctance to ask for help unless they believe it is absolutely necessary, a situation which could impact on the safety of patients. This study aimed to develop a theoretical exploration of the pressure on medical trainees to be independent and to generate theory-based approaches to the implications for patient safety of this pressure towards independent working. In Phase 1, 88 teaching team members from internal and emergency medicine were observed during clinical activities (216 hours), and 65 participants completed brief interviews. In Phase 2, 36 in-depth interviews were conducted using video vignettes. Data collection and analysis employed grounded theory methodology. Participants conceived that the pressure towards independence in clinical work originated in trainees' desire to lay claim to the identity of a doctor (as a member of a group of autonomous high achievers), and in organisational issues such as heavy workloads and constant evaluations. The identity and organisational issues related to the pressure towards independence were explored through the lenses of established theories from education and psychology. Consideration of Lave and Wenger's situated learning theory suggests that giving attention to the 'independent doctor' ideal, through measures such as involving trainees when their supervisors ask for help, could impact the safety of teaching team practice. Amalberti et al.'s migration model explains how pressures to maximise productivity and individual gain may cause teaching teams to migrate beyond the boundaries of safe practice and suggests that managing triggers (such as workload and high-stakes evaluations) for violations of safe practice might improve safety. Implementation and evaluation of these theory-based approaches to the safety of teaching team practice would contribute to a better understanding of the links between trainee independence and patient safety.

  17. Overtime work and blood pressure in normotensive Japanese male workers.

    PubMed

    Nakamura, Koshi; Sakurai, Masaru; Morikawa, Yuko; Miura, Katsuyuki; Ishizaki, Masao; Kido, Teruhiko; Naruse, Yuchi; Suwazono, Yasushi; Nakagawa, Hideaki

    2012-09-01

    Epidemiological studies have observed conflicting patterns as to whether overtime work increases blood pressure (BP), probably as a consequence of methodological issues. We conducted a prospective cohort study to investigate the relationship between overtime work hours and 1-year changes in BP in 1,235 normotensive Japanese male workers who carried out a variety of jobs in a manufacturing factory. Casual BP measurements were repeated at annual health examinations in 2004-2005, using an automatic manometer. An analysis of covariance that incorporated potential confounding factors including baseline age, body mass index (BMI), and lifestyle factors was used to calculate and compare the means of the 1-year change in systolic (SBP) and diastolic BP (DBP). The participants were grouped according to their average monthly overtime work hours obtained from timecard data between April and September 2004. The multivariate-adjusted mean for 1-year change in DBP in 611 male assembly-line workers was 1.5 mm Hg (95% confidence interval (CI) 0.8-2.2) for <40.0 h/month, 2.3 mm Hg (95% CI 1.3-3.2) for 40.0-79.9 h/month, and 5.3 mm Hg (95% CI 2.7-7.9) for ≥ 80.0 h/month (P for heterogeneity = 0.02). A broadly similar pattern was observed for SBP. In contrast, there was no significant difference in means 1-year change for both SBP and DBP in 315 clerks and 309 engineers/special technicians, grouped according to overtime work hours. Extensive overtime work was associated with increased BP in normotensive male assembly-line workers, but not in clerks and engineers/special technicians.

  18. Blood pressure monitoring: theory and practice. European Society of Hypertension Working Group on Blood Pressure Monitoring and Cardiovascular Variability Teaching Course Proceedings.

    PubMed

    Stergiou, George S; Palatini, Paolo; Asmar, Roland; Bilo, Grzegorz; de la Sierra, Alejandro; Head, Geoff; Kario, Kazuomi; Mihailidou, Anastasia; Wang, Jiguang; Mancia, Giuseppe; O'Brien, Eoin; Parati, Gianfranco

    2018-02-01

    The European Society of Hypertension (ESH) Working Group on Blood Pressure (BP) Monitoring and Cardiovascular Variability organized a Teaching Course on 'Blood Pressure Monitoring: Theory and Practice' during the 2017 ESH Meeting in Milan, Italy. This course performed by 11 international BP monitoring experts covered key topics of BP monitoring, including office BP measurement, ambulatory BP monitoring, home BP monitoring, ambulatory versus home BP, white-coat and masked hypertension, cuff use, and BP variability. This article presents a summary of the proceedings of the ESH BP Monitoring Teaching Course, including essential information, practical issues, and recommendations on the clinical application of BP monitoring methods, aiming to the optimal management of patients with suspected or diagnosed hypertension.

  19. Intracranial Pressure Monitoring—Review and Avenues for Development

    PubMed Central

    Dolmans, Rianne G. F.

    2018-01-01

    Intracranial pressure (ICP) monitoring is a staple of neurocritical care. The most commonly used current methods of monitoring in the acute setting include fluid-based systems, implantable transducers and Doppler ultrasonography. It is well established that management of elevated ICP is critical for clinical outcomes. However, numerous studies show that current methods of ICP monitoring cannot reliably define the limit of the brain’s intrinsic compensatory capacity to manage increases in pressure, which would allow for proactive ICP management. Current work in the field hopes to address this gap by harnessing live-streaming ICP pressure-wave data and a multimodal integration with other physiologic measures. Additionally, there is continued development of non-invasive ICP monitoring methods for use in specific clinical scenarios. PMID:29401746

  20. Measuring the electronic transport properties of individual nano-objects under high pressures

    NASA Astrophysics Data System (ADS)

    Caillier, C.; Ayari, A.; Le Floch, S.; Féret, H.; Guiraud, G.; San-Miguel, A.

    2011-09-01

    We describe a setup to carry out electronic transport measurements under high pressures on individual nano-objects. It is based on a home-automated three-stage gas compressor working with argon or helium up to 1 GPa. The setup was successfully tested on contacted individual nanotubes, for which we evidence strong evolutions of the transport properties. These evolutions are related to fundamental issues such as the modification of the nano-object contact resistance, the pressure-induced modification of the nano-object geometry or pressure-induced changes in the intrinsic electronic properties of the nanosystem. A cryostat has also been adapted to the pressure cell, allowing combined pressure and temperature experiments down to 12 K.

  1. Pulmonary Artery Wedge Pressure Relative to Exercise Work Rate in Older Men and Women.

    PubMed

    Esfandiari, Sam; Wright, Stephen P; Goodman, Jack M; Sasson, Zion; Mak, Susanna

    2017-07-01

    An augmented pulmonary artery wedge pressure (PAWP) response may explain exercise intolerance in some humans. However, routine use of exercise hemodynamic testing is limited by a lack of data from normal older men and women. Our objective was to evaluate the exercise PAWP response and the potential for sexual dimorphism in healthy, nondyspneic older adults. Thirty-six healthy volunteers (18 men [54 ± 7 yr] and 18 women [58 ± 6 yr]) were studied at rest (control) and during two stages of semi-upright cycle ergometry, at heart rates of 100 bpm (light exercise) and 120 bpm (moderate exercise). Right heart catheterization was performed to measure pulmonary pressures. The PAWP response to exercise was assessed in context of exercise work rate and body size. At control, PAWP was similar between men and women. Work rates were significantly smaller in women at comparable HR (P < 0.001). PAWP increased similarly at light exercise, with no further increase at moderate exercise. When indexed to work rate alone or work rate adjusted to body weight and height, the PAWP response at light and moderate exercise was significantly elevated in women compared with men (P < 0.05 condition-sex interaction). The change in PAWP relative to the increase in cardiac output did not exceed 2 mm Hg·L·min in any volunteer at moderate exercise. The similar rise in the PAWP response to submaximal exercise occurs despite lower work rate in healthy older women compared with men, even when adjusted for smaller body size. It is important to consider sex in the development of normal reference ranges for exercise hemodynamic testing.

  2. Continuous monitoring of regional function by a miniaturized ultrasound transducer allows early quantification of low-grade myocardial ischemia.

    PubMed

    Hyler, Stefan; Pischke, Søren E; Halvorsen, Per Steinar; Espinoza, Andreas; Bergsland, Jacob; Tønnessen, Tor Inge; Fosse, Erik; Skulstad, Helge

    2015-04-01

    Sensitive methods for the early detection of myocardial dysfunction are still needed, as ischemia is a leading cause of decreased ventricular function during and after heart surgery. The aim of this study was to test the hypothesis that low-grade ischemia could be detected quantitatively by a miniaturized epicardial ultrasound transducer (Ø = 3 mm), allowing continuous monitoring. In 10 pigs, transducers were positioned in the left anterior descending and circumflex coronary artery areas. Left ventricular pressure was obtained by a micromanometer. The left internal mammary artery was grafted to the left anterior descending coronary artery, which was occluded proximal to the anastomosis. Left internal mammary artery flow was stepwise reduced by 25%, 50%, and 75% for 18 min each. From the transducers, M-mode traces were obtained, allowing continuous tissue velocity traces and displacement measurements. Regional work was assessed as left ventricular pressure-displacement loop area. Tissue lactate measured from intramyocardial microdialysis was used as reference method to detect ischemia. All steps of coronary flow reduction demonstrated reduced peak systolic velocity (P < .05) and regional work (P < .01).The decreases in peak systolic velocity and regional work were closely related to the degree of ischemia, demonstrated by their correlations with lactate (R = -0.74, P < .01, and R = -0.64, P < .01, respectively). The circumflex coronary artery area was not affected by any of the interventions. The epicardially attached miniaturized ultrasound transducer allowed the precise detection of different levels of coronary flow reduction. The results also showed a quantitative and linear relationship among coronary flow, ischemia, and myocardial function. Thus, the ultrasound transducer has the potential to improve the monitoring of myocardial ischemia and to detect graft failure during and after heart surgery. Copyright © 2015 American Society of Echocardiography

  3. Numerical investigations on pressurized AL-composite vessel response to hypervelocity impacts: Comparison between experimental works and a numerical code

    NASA Astrophysics Data System (ADS)

    Mespoulet, Jérôme; Plassard, Fabien; Hereil, Pierre-Louis

    2015-09-01

    Response of pressurized composite-Al vessels to hypervelocity impact of aluminum spheres have been numerically investigated to evaluate the influence of initial pressure on the vulnerability of these vessels. Investigated tanks are carbon-fiber overwrapped prestressed Al vessels. Explored internal air pressure ranges from 1 bar to 300 bar and impact velocity are around 4400 m/s. Data obtained from experiments (Xray radiographies, particle velocity measurement and post-mortem vessels) have been compared to numerical results given from LS-DYNA ALE-Lagrange-SPH full coupling models. Simulations exhibit an under estimation in term of debris cloud evolution and shock wave propagation in pressurized air but main modes of damage/rupture on the vessels given by simulations are coherent with post-mortem recovered vessels from experiments. First results of this numerical work are promising and further simulation investigations with additional experimental data will be done to increase the reliability of the simulation model. The final aim of this crossed work is to numerically explore a wide range of impact conditions (impact angle, projectile weight, impact velocity, initial pressure) that cannot be explore experimentally. Those whole results will define a rule of thumbs for the definition of a vulnerability analytical model for a given pressurized vessel.

  4. Glassy selenium at high pressure: Le Chatelier's principle still works

    NASA Astrophysics Data System (ADS)

    Brazhkin, V. V.; Tsiok, O. B.

    2017-10-01

    Selenium is the only easily vitrified elementary substance. Numerous experimental studies of glassy Se (g -Se) at high pressures show a large spread in the data on the compressibility and electrical resistivity of g -Se. Furthermore, H. Liu et al. [Proc. Natl. Acad. Sci. USA 105, 13229 (2008), 10.1073/pnas.0806857105] have arrived at the surprising conclusion that the volume of glass increases during pressure-induced crystallization. We have performed high-precision measurements of the specific volume and electrical resistivity of glassy selenium (g -Se) at high hydrostatic pressures up to 9 GPa. The measured bulk modulus at normal pressure is B =(9.0 5 ±0.15 ) GPa and its pressure derivative is BP'=6.4 ±0.2 . In the pressure range P <3 GPa, glassy selenium has an anomalously large negative second derivative of the bulk modulus. The electrical resistivity of g -Se decreases almost exponentially with increasing pressure and reaches 20 Ω cm at a pressure of 8.75 GPa. The inelastic behavior and weak relaxation of the volume for g -Se begin at pressures above 3.5 GPa; the volume and logarithm of the electrical resistivity relax significantly (logarithmically with the time) at pressures above 8 GPa. Bulk measurements certainly indicate that the volume of g -Se glass in the crystallization pressure range is larger than the volumes of both appearing crystalline phases (by 2% and 4%). Therefore, the "volume expansion phenomenon" suggested in [H. Liu et al., Proc. Natl. Acad. Sci. USA 105, 13229 (2008), 10.1073/pnas.0806857105] is not observed, and the pressure-induced crystallization of glassy selenium is consistent with the laws of thermodynamics.

  5. Effect of working power and pressure on plasma properties during the deposition of TiN films in reactive magnetron sputtering plasma measured using Langmuir probe measurement

    NASA Astrophysics Data System (ADS)

    How, Soo Ren; Nayan, Nafarizal; Khairul Ahmad, Mohd; Fhong Soon, Chin; Zainizan Sahdan, Mohd; Lias, Jais; Shuhaimi Abu Bakar, Ahmad; Arshad, Mohd Khairuddin Md; Hashim, Uda; Yazid Ahmad, Mohd

    2018-04-01

    The ion, electron density and electron temperature during formation of TiN films in reactive magnetron sputtering system have been investigated for various settings of radio frequency (RF) power and working pressure by using Langmuir probe measurements. The RF power and working pressure able to affect the densities and plasma properties during the deposition process. In this work, a working pressure (100 and 20 mTorr) and RF power (100, 150 and 200 W) have been used for data acquisition of probe measurement. Fundamental of studied on sputter deposition is very important for improvement of film quality and deposition rate. Higher working pressure and RF power able to produce a higher ion density and reduction of electron temperature.

  6. Work-Hardening Induced Tensile Ductility of Bulk Metallic Glasses via High-Pressure Torsion

    PubMed Central

    Joo, Soo-Hyun; Pi, Dong-Hai; Setyawan, Albertus Deny Heri; Kato, Hidemi; Janecek, Milos; Kim, Yong Chan; Lee, Sunghak; Kim, Hyoung Seop

    2015-01-01

    The mechanical properties of engineering materials are key for ensuring safety and reliability. However, the plastic deformation of BMGs is confined to narrow regions in shear bands, which usually result in limited ductilities and catastrophic failures at low homologous temperatures. The quasi-brittle failure and lack of tensile ductility undercut the potential applications of BMGs. In this report, we present clear tensile ductility in a Zr-based BMG via a high-pressure torsion (HPT) process. Enhanced tensile ductility and work-hardening behavior after the HPT process were investigated, focusing on the microstructure, particularly the changed free volume, which affects deformation mechanisms (i.e., initiation, propagation, and obstruction of shear bands). Our results provide insights into the basic functions of hydrostatic pressure and shear strain in the microstructure and mechanical properties of HPT-processed BMGs. PMID:25905686

  7. Time for Self-Care: Downtime Recovery as a Buffer of Work and Home/Family Time Pressures.

    PubMed

    Dugan, Alicia G; Barnes-Farrell, Janet L

    2017-04-01

    Opportunities for people to recover from stress are insufficient, because demanding and excessive life activities leave little time for recovery. Downtime is a self-care behavior that can occur in any life domain (ie, work, home/family, leisure). Using survey data from a cross-section of 422 U.S. workers, we tested hypotheses regarding downtime as a buffer of the effects of time pressure and whether downtime's benefits were related to the domain in which it was taken, or influenced by perceived time control. In situations of high time pressure, work and home/family downtime were beneficial when time control was high, while relaxing leisure was beneficial when time control was low. Downtime is available whenever people recognize their need for recovery and respond by entering a state of physical relaxation and psychological detachment from stressors.

  8. 40 CFR 35.2205 - Maximum allowable project cost.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 1 2010-07-01 2010-07-01 false Maximum allowable project cost. 35.2205... ASSISTANCE STATE AND LOCAL ASSISTANCE Grants for Construction of Treatment Works § 35.2205 Maximum allowable... regulation, the maximum allowable project cost will be the sum of: (1) The allowable cost of the following...

  9. A new methodological approach to assess cardiac work by pressure-volume and stress-length relations in patients with aortic valve stenosis and dilated cardiomyopathy.

    PubMed

    Alter, P; Rupp, H; Rominger, M B; Klose, K J; Maisch, B

    2008-01-01

    In experimental animals, cardiac work is derived from pressure-volume area and analyzed further using stress-length relations. Lack of methods for determining accurately myocardial mass has until now prevented the use of stress-length relations in patients. We hypothesized, therefore, that not only pressure-volume loops but also stress-length diagrams can be derived from cardiac volume and cardiac mass as assessed by cardiac magnetic resonance imaging (CMR) and invasively measured pressure. Left ventricular (LV) volume and myocardial mass were assessed in seven patients with aortic valve stenosis (AS), eight with dilated cardiomyopathy (DCM), and eight controls using electrocardiogram (ECG)-gated CMR. LV pressure was measured invasively. Pressure-volume curves were calculated based on ECG triggering. Stroke work was assessed as area within the pressure-volume loop. LV wall stress was calculated using a thick-wall sphere model. Similarly, stress-length loops were calculated to quantify stress-length-based work. Taking the LV geometry into account, the normalization with regard to ventricular circumference resulted in "myocardial work." Patients with AS (valve area 0.73+/-0.18 cm(2)) exhibited an increased LV myocardial mass when compared with controls (P<0.05). LV wall stress was increased in DCM but not in AS. Stroke work of AS was unchanged when compared with controls (0.539+/-0.272 vs 0.621+/-0.138 Nm, not significant), whereas DCM exhibited a significant depression (0.367+/-0.157 Nm, P<0.05). Myocardial work was significantly reduced in both AS and DCM when compared with controls (129.8+/-69.6, 200.6+/-80.1, 332.2+/-89.6 Nm/m(2), P<0.05), also after normalization (7.40+/-5.07, 6.27+/-3.20, 14.6+/-4.07 Nm/m(2), P<0.001). It is feasible to obtain LV pressure-volume and stress-length diagrams in patients based on the present novel methodological approach of using CMR and invasive pressure measurement. Myocardial work was reduced in patients with DCM and noteworthy

  10. Low pressure cold spraying on materials with low erosion resistance

    NASA Astrophysics Data System (ADS)

    Shikalov, V. S.; Klinkov, S. V.; Kosarev, V. F.

    2017-10-01

    In present work, the erosion-adhesion transition was investigated during cold spraying of aluminum particles on brittle ceramic substrates. Cold spraying was carried out with aid of sonic nozzle, which use allows significantly reducing the gas stagnation pressure without the effect of flow separation inside the nozzle and, accordingly, reducing the velocity of the spraying particles. Two stagnation pressures were chosen. The coating tracks were sprayed at different air temperatures in nozzle pre-chamber under each of regimes. Single sprayed tracks were obtained and their profiles were investigated by optical profilometry.

  11. Energy transfer, pressure tensor, and heating of kinetic plasma

    NASA Astrophysics Data System (ADS)

    Yang, Yan; Matthaeus, William H.; Parashar, Tulasi N.; Haggerty, Colby C.; Roytershteyn, Vadim; Daughton, William; Wan, Minping; Shi, Yipeng; Chen, Shiyi

    2017-07-01

    Kinetic plasma turbulence cascade spans multiple scales ranging from macroscopic fluid flow to sub-electron scales. Mechanisms that dissipate large scale energy, terminate the inertial range cascade, and convert kinetic energy into heat are hotly debated. Here, we revisit these puzzles using fully kinetic simulation. By performing scale-dependent spatial filtering on the Vlasov equation, we extract information at prescribed scales and introduce several energy transfer functions. This approach allows highly inhomogeneous energy cascade to be quantified as it proceeds down to kinetic scales. The pressure work, - ( P . ∇ ) . u , can trigger a channel of the energy conversion between fluid flow and random motions, which contains a collision-free generalization of the viscous dissipation in collisional fluid. Both the energy transfer and the pressure work are strongly correlated with velocity gradients.

  12. CONFERENCE NOTE: Comité Consultatif pour la Masse et les grandeurs apparentées (CCM), High Pressure and Medium Pressure Working Groups, Second International Seminar on Pressure Metrology from 1 kPa to 1 GPa

    NASA Astrophysics Data System (ADS)

    1992-01-01

    The seminar will be held from 2 to 4 June 1993, preceding the next meeting of the CCM, at the Laboratoire National d'Essais (LNE), 1 rue Gaston Boissier, 75015 Paris, France. Scope of the Seminar The purpose of the seminar is to review the state of the art of pressure measurements in the 1 kPa to 1 GPa range and to present original and innovative contributions from standards laboratories and industry. Main Topics The seminar will be organized in six sessions as follows: Liquid-column manometers Piston gauge pressure standards Properties of liquids and gases relevant to pressure metrology Pressure transducers and transfer standards Pressure standard comparison (methods and results) Dynamic pressure measurements. Each topic will be introduced by a review paper presented by a session chairman. A final session, coordinated by Dr G F Molinar (IMGC), Chairman of the CCM High Pressure Working Group, and Dr P Stuart (NPL), Chairman of the CCM Medium Pressure Working Group, will deal with: Actual limits of accuracy of static pressure measurements in fluid media Fundamental problems in pressure metrology between I kPa and 1 GPa. Call for Papers Papers should be prepared for oral presentation and will be refereed by the session chairmen. The Proceedings will be published as a special issue of Metrologia. Papers should be written according to the instructions for authors printed on the inside back cover of this journal. A one-page abstract should be sent to Dr Molinar at the IMGC, to arrive before 31 January 1993. A participation fee of 900 FFr (175 US) will be charged. This will cover general expenses and a copy of the Proceedings. Hotel reservations, meals and transport are not included. Organizers For further information please contact: 1993 CCM Pressure Seminar, Dr G F Molinar, Istituto di Metrologia "G Colonnetti", Strada delle Cacce 73, 1-10135 Torino, Italy telephone (39) 11 39771; telex 212209 IMGCTO-I; fax (39) 11 346761. Contact at the LNE: J C Legras, telephone (33

  13. Instantaneous, phase-averaged, and time-averaged pressure from particle image velocimetry

    NASA Astrophysics Data System (ADS)

    de Kat, Roeland

    2015-11-01

    Recent work on pressure determination using velocity data from particle image velocimetry (PIV) resulted in approaches that allow for instantaneous and volumetric pressure determination. However, applying these approaches is not always feasible (e.g. due to resolution, access, or other constraints) or desired. In those cases pressure determination approaches using phase-averaged or time-averaged velocity provide an alternative. To assess the performance of these different pressure determination approaches against one another, they are applied to a single data set and their results are compared with each other and with surface pressure measurements. For this assessment, the data set of a flow around a square cylinder (de Kat & van Oudheusden, 2012, Exp. Fluids 52:1089-1106) is used. RdK is supported by a Leverhulme Trust Early Career Fellowship.

  14. Task demands and the pressures of everyday life: associations between cardiovascular reactivity and work blood pressure and heart rate.

    PubMed

    Steptoe, A; Cropley, M; Joekes, K

    2000-01-01

    Associations between cardiovascular stress reactivity and blood pressure and heart rate recorded in everyday life were hypothesized to depend on the stressfulness of the ambulatory monitoring period relative to standardized tasks and on activity levels at the time of measurement. One hundred two female and 60 male school teachers carried out high- and low-demand tasks under standardized conditions and ambulatory monitoring during the working day. Stress ratings during the day were close to those recorded during the low-demand task. Reactions to the low-demand task were significant predictors of ambulatory blood pressure and heart rate independent of baseline, age, gender, and body mass. Associations were more consistent for ambulatory recordings taken when participants were seated than when they were standing and when the ambulatory monitoring day was considered to be as stressful as usual or more stressful than usual, and not less stressful than usual. Laboratory-field associations of cardiovascular activity depend in part on the congruence of stressfulness and physical activity level in the 2 situations.

  15. Risk of high blood pressure in salt workers working near salt milling plants: A cross-sectional and interventional study

    PubMed Central

    Haldiya, Kripa Ram; Mathur, Murli Lal; Sachdev, Raman; Saiyed, Habibulla N

    2005-01-01

    Background Workers working close to salt milling plants may inhale salt particles floating in the air, leading to a rise in plasma sodium, which, in turn, may increase the blood pressure and the risk of hypertension. Methods To test the above hypothesis, occupational health check-up camps were organized near salt manufacturing units and all workers were invited for a free health examination. The workers who worked with dry salt in the vicinity of salt milling plants were defined as "non-brine workers," while those working in brine pans located far away from milling plants were defined as "brine workers." Blood pressure (BP) was measured during each clinical examination. In all, 474 non-brine workers and 284 brine workers were studied. Results Mean systolic blood pressure of non-brine workers (122.1 ± 13.3 mm Hg) was significantly higher than that of brine workers (118.8 ± 12.8 mm Hg, p < 0.01). Mean diastolic blood pressure of non-brine workers (71.5 ± 10.4 mm Hg) was significantly higher than that of brine workers (69.7 ± 9.4 mm Hg, p = 0.02). The prevalence of hypertension was significantly higher in non-brine workers (12.2%) than in brine workers (7.0%, p = 0.02). Nineteen salt workers were monitored while they used face masks and spectacles, for six days. Systolic, as well as diastolic, blood pressure of these workers began declining on the third day and continued to decline on the fourth day, but remained stationary up to the sixth day. The concentration of salt particles in the breathing zone of these workers was 376 mg/m3 air. Conclusion Inhalation of salt particles in non-brine workers may be an occupational cause of increased blood pressure. PMID:16042798

  16. Investigation of holder pressure and size effects in micro deep drawing of rectangular work pieces driven by piezoelectric actuator.

    PubMed

    Aminzahed, Iman; Mashhadi, Mahmoud Mosavi; Sereshk, Mohammad Reza Vaziri

    2017-02-01

    Micro forming is a manufacturing process to fabricate micro parts with high quality and a cost effective manner. Deep drawing could be a favorable method for production of complicated parts in macro and micro sizes. In this paper piezoelectric actuator is used as a novel approach in the field of micro manufacturing. Also, in current work, investigations are conducted with four rectangular punches and blanks with various thicknesses. Blank holder pressure effects on thickness distributions, punch force, and springback are studied. According to the results of this work, increasing of blank holder pressure in scaled deep drawing, in contrast to thickness of drawn part, leads to decrease in the punch forces and springback. Furthermore, it is shown that in micro deep drawing, the effects of holder pressure on mentioned parameters can be ignored. Copyright © 2016 Elsevier B.V. All rights reserved.

  17. Portable Dynamic Pressure Calibrator

    NASA Technical Reports Server (NTRS)

    Wright, Morgan S.; Maynard, Everett (Technical Monitor)

    1996-01-01

    A portable, dynamic pressure calibrator was fabricated for use on wind tunnel models at NASA-Ames Research Center. The calibrator generates sine wave pressures at levels up to 1 PSIG P-P(168dB) at frequencies from 10Hz to 6KHz and .5 PSIG P.P (162dB) at frequencies from 6KHz to 20KHz. The calibrator consists of two units connected by a single cable. The handheld unit contains a pressure transducer, speaker, and deadman switch. This unit allows application of dynamic pressure to transducers/ports on installed wind tunnel models. The base unit contains all of power supplies, controls and displays. This unit allows amplitude and frequency to be set and verified at a safe location off of the model.

  18. The importance of capillary density-stroke work mismatch for right ventricular adaptation to chronic pressure overload.

    PubMed

    Noly, Pierre-Emmanuel; Haddad, François; Arthur-Ataam, Jennifer; Langer, Nathaniel; Dorfmüller, Peter; Loisel, Fanny; Guihaire, Julien; Decante, Benoit; Lamrani, Lilia; Fadel, Elie; Mercier, Olaf

    2017-12-01

    Mechanisms of right ventricular (RV) adaptation to chronic pressure overload are not well understood. We hypothesized that a lower capillary density (CD) to stroke work ratio would be associated with more fibrosis and RV maladaptive remodeling. We induced RV chronic pressure overload over a 20-week period in 2 piglet models of pulmonary hypertension; that is, a shunt model (n = 5) and a chronic thromboembolic pulmonary hypertension model (n = 5). We assessed hemodynamic parameters and RV remodeling as well as RV CD, fibrosis, and angiogenic factors expression. Although RV was similarly hypertrophied in both models, maladapted RV remodeling with impaired systolic function was only seen in chronic thromboembolic pulmonary hypertension group members who had lower CD (484 ± 99 vs 1213 ± 74 cap/mm 2 ; P < .01), lower CD to stroke work ratio (0.29 ± 0.07 vs 0.82 ± 0.16; P = .02), higher myocardial fibrosis (15.4% ± 3.8% vs 8.0% ± 2.5%; P < .01), as well as a higher angiogenic and fibrosis factors expression. The RV adaptive response to chronic pressure overload differs between 2 different piglet models of PH. Mismatch between angiogenesis and workload (CD to stroke work ratio) was associated with greater degree of myocardial fibrosis and RV dysfunction and could be a promising index of RV maladaptation. Further studies are needed to understand the underlying mechanisms. Copyright © 2017 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.

  19. Crystallization of hard spheres revisited. II. Thermodynamic modeling, nucleation work, and the surface of tension.

    PubMed

    Richard, David; Speck, Thomas

    2018-06-14

    Combining three numerical methods (forward flux sampling, seeding of droplets, and finite-size droplets), we probe the crystallization of hard spheres over the full range from close to coexistence to the spinodal regime. We show that all three methods allow us to sample different regimes and agree perfectly in the ranges where they overlap. By combining the nucleation work calculated from forward flux sampling of small droplets and the nucleation theorem, we show how to compute the nucleation work spanning three orders of magnitude. Using a variation of the nucleation theorem, we show how to extract the pressure difference between the solid droplet and ambient liquid. Moreover, combining the nucleation work with the pressure difference allows us to calculate the interfacial tension of small droplets. Our results demonstrate that employing bulk quantities yields inaccurate results for the nucleation rate.

  20. Differential pressure pin discharge apparatus

    DOEpatents

    Oakley, David J.

    1987-02-03

    Disclosed is a discharge assembly for allowing elongate pins to be discharged from an area of relatively low pressure to an area of relatively greater pressure. The discharge assembly includes a duck valve having a lip piece made of flexible material. The flexible lip piece responds to a fluctuating pressure created downstream by an aspirator. The aspirator reduces the downstream pressure sensed by the duck valve when the discharge assembly is in the open position. This allows elongate pins to be moved through the duck valve with no backflow because the aspirator pressure is less than the pressure in the low pressure area from which the pins originate. Closure of the assembly causes the aspirator static pressure to force the flexible duck valve lip piece into a tightly sealed position also preventing backflow. The discharge assembly can be easily controlled using a single control valve which blocks the flow of aspirator gas and closes the pin passageway extending through the assembly.

  1. Differential pressure pin discharge apparatus

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Oakley, D.J.

    Disclosed is a discharge assembly for allowing elongate pins to be discharged from an area of relatively low pressure to an area of relatively greater pressure. The discharge assembly includes a duck valve having a lip piece made of flexible material. The flexible lip piece responds to a fluctuating pressure created downstream by an aspirator. The aspirator reduces the downstream pressure sensed by the duck valve when the discharge assembly is in the open position. This allows elongate pins to be moved through the duck valve with no backflow because the aspirator pressure is less than the pressure in themore » low pressure area from which the pins originate. Closure of the assembly causes the aspirator static pressure to force the flexible duck valve lip piece into a tightly sealed position also preventing backflow. The discharge assembly can be easily controlled using a single control valve which blocks the flow of aspirator gas and closes the pins passageway extending through the assembly.« less

  2. Differential pressure pin discharge apparatus

    DOEpatents

    Oakley, D.J.

    1984-05-30

    Disclosed is a discharge assembly for allowing elongate pins to be discharged from an area of relatively low pressure to an area of relatively greater pressure. The discharge assembly includes a duck valve having a lip piece made of flexible material. The flexible lip piece responds to a fluctuating pressure created downstream by an aspirator. The aspirator reduces the downstream pressure sensed by the duck valve when the discharge assembly is in the open position. This allows elongate pins to be moved through the duck valve with no backflow because the aspirator pressure is less than the pressure in the low pressure area from which the pins originate. Closure of the assembly causes the aspirator static pressure to force the flexible duck valve lip piece into a tightly sealed position also preventing backflow. The discharge assembly can be easily controlled using a single control valve which blocks the flow of aspirator gas and closes the pins passageway extending through the assembly.

  3. Differential pressure pin discharge apparatus

    DOEpatents

    Oakley, David J.

    1987-01-01

    Disclosed is a discharge assembly for allowing elongate pins to be discharged from an area of relatively low pressure to an area of relatively greater pressure. The discharge assembly includes a duck valve having a lip piece made of flexible material. The flexible lip piece responds to a fluctuating pressure created downstream by an aspirator. The aspirator reduces the downstream pressure sensed by the duck valve when the discharge assembly is in the open position. This allows elongate pins to be moved through the duck valve with no backflow because the aspirator pressure is less than the pressure in the low pressure area from which the pins originate. Closure of the assembly causes the aspirator static pressure to force the flexible duck valve lip piece into a tightly sealed position also preventing backflow. The discharge assembly can be easily controlled using a single control valve which blocks the flow of aspirator gas and closes the pin passageway extending through the assembly.

  4. Blood Pressure Medicines

    MedlinePlus

    ... reducing sodium in your diet, you may need medicines. Blood pressure medicines work in different ways to lower blood pressure. ... and widen blood vessels. Often, two or more medicines work better than one. NIH: National Heart, Lung, ...

  5. System Would Regulate Low Gas Pressure

    NASA Technical Reports Server (NTRS)

    Frazer, Robert E.

    1994-01-01

    System intended to maintain gases in containers at pressures near atmospheric. Includes ballast volume in form of underinflated balloon that communicates with working volume. Balloon housed in rigid chamber not subjected to extremes of temperature of working volume. Pressure in chamber surrounding balloon regulated at ambient atmospheric pressure or at constant small differential pressure above or below ambient. Expansion and contraction of balloon accommodates expansion or contraction of gas during operational heating or cooling in working volume, maintaining pressure in working volume at ambient or constant differential above or below ambient. Gas lost from system due to leakage or diffusion, low-pressure sensor responds, signaling valve actuators to supply more gas to working volume. If pressure rises too high, overpressure relief valve opens before excessive pressure damages system.

  6. Progress Report on Alloy 617 Time Dependent Allowables

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wright, Julie Knibloe

    2015-06-01

    Time dependent allowable stresses are required in the ASME Boiler and Pressure Vessel Code for design of components in the temperature range where time dependent deformation (i.e., creep) is expected to become significant. There are time dependent allowable stresses in Section IID of the Code for use in the non-nuclear construction codes, however, there are additional criteria that must be considered in developing time dependent allowables for nuclear components. These criteria are specified in Section III NH. St is defined as the lesser of three quantities: 100% of the average stress required to obtain a total (elastic, plastic, primary andmore » secondary creep) strain of 1%; 67% of the minimum stress to cause rupture; and 80% of the minimum stress to cause the initiation of tertiary creep. The values are reported for a range of temperatures and for time increments up to 100,000 hours. These values are determined from uniaxial creep tests, which involve the elevated temperature application of a constant load which is relatively small, resulting in deformation over a long time period prior to rupture. The stress which is the minimum resulting from these criteria is the time dependent allowable stress St. In this report data from a large number of creep and creep-rupture tests on Alloy 617 are analyzed using the ASME Section III NH criteria. Data which are used in the analysis are from the ongoing DOE sponsored high temperature materials program, form Korea Atomic Energy Institute through the Generation IV VHTR Materials Program and historical data from previous HTR research and vendor data generated in developing the alloy. It is found that the tertiary creep criterion determines St at highest temperatures, while the stress to cause 1% total strain controls at low temperatures. The ASME Section III Working Group on Allowable Stress Criteria has recommended that the uncertainties associated with determining the onset of tertiary creep and the lack of significant

  7. Electronically scanned pressure sensor module with in SITU calibration capability

    NASA Technical Reports Server (NTRS)

    Gross, C. (Inventor)

    1978-01-01

    This high data rate pressure sensor module helps reduce energy consumption in wind tunnel facilities without loss of measurement accuracy. The sensor module allows for nearly a two order of magnitude increase in data rates over conventional electromechanically scanned pressure sampling techniques. The module consists of 16 solid state pressure sensor chips and signal multiplexing electronics integrally mounted to a four position pressure selector switch. One of the four positions of the pressure selector switch allows the in situ calibration of the 16 pressure sensors; the three other positions allow 48 channels (three sets of 16) pressure inputs to be measured by the sensors. The small size of the sensor module will allow mounting within many wind tunnel models, thus eliminating long tube lengths and their corresponding slow pressure response.

  8. A Venturi microregulator array module for distributed pressure control

    PubMed Central

    Chang, Dustin S.; Langelier, Sean M.; Zeitoun, Ramsey I.

    2010-01-01

    Pressure-driven flow control systems are a critical component in many microfluidic devices. Compartmentalization of this functionality into a stand-alone module possessing a simple interface would allow reduction of the number of pneumatic interconnects required for fluidic control. Ideally, such a module would also be sufficiently compact for implementation in portable platforms. In our current work, we show the feasibility of using a modular array of Venturi pressure microregulators for coordinated droplet manipulation. The arrayed microregulators share a single pressure input and are capable of outputting electronically controlled pressures that can be independently set between ±1.3 kPa. Because the Venturi microregulator operates by thermal perturbation of a choked gas flow, this output range corresponds to a temperature variation between 20 and 95°C. Using the array, we demonstrate loading, splitting, merging, and independent movement of multiple droplets in a valveless microchannel network. PMID:20938490

  9. Computational Analyses of Pressurization in Cryogenic Tanks

    NASA Technical Reports Server (NTRS)

    Ahuja, Vineet; Hosangadi, Ashvin; Mattick, Stephen; Lee, Chun P.; Field, Robert E.; Ryan, Harry

    2008-01-01

    A) Advanced Gas/Liquid Framework with Real Fluids Property Routines: I. A multi-fluid formulation in the preconditioned CRUNCH CFD(Registered TradeMark) code developed where a mixture of liquid and gases can be specified: a) Various options for Equation of state specification available (from simplified ideal fluid mixtures, to real fluid EOS such as SRK or BWR models). b) Vaporization of liquids driven by pressure value relative to vapor pressure and combustion of vapors allowed. c) Extensive validation has been undertaken. II. Currently working on developing primary break-up models and surface tension effects for more rigorous phase-change modeling and interfacial dynamics B) Framework Applied to Run-time Tanks at Ground Test Facilities C) Framework Used For J-2 Upper Stage Tank Modeling: 1) NASA MSFC tank pressurization: a) Hydrogen and oxygen tank pre-press, repress and draining being modeled at NASA MSFC. 2) NASA AMES tank safety effort a) liquid hydrogen and oxygen are separated by a baffle in the J-2 tank. We are modeling pressure rise and possible combustion if a hole develops in the baffle and liquid hydrogen leaks into the oxygen tank. Tank pressure rise rates simulated and risk of combustion evaluated.

  10. Permeability and elastic properties of cracked glass under pressure

    NASA Astrophysics Data System (ADS)

    Ougier-Simonin, A.; GuéGuen, Y.; Fortin, J.; Schubnel, A.; Bouyer, F.

    2011-07-01

    Fluid flow in rocks is allowed through networks of cracks and fractures at all scales. In fact, cracks are of high importance in various applications ranging from rock elastic and transport properties to nuclear waste disposal. The present work aims at investigating thermomechanical cracking effects on elastic wave velocities, mechanical strength, and permeability of cracked glass under pressure. We performed the experiments on a triaxial cell at room temperature which allows for independent controls of the confining pressure, the axial stress, and pore pressure. We produced cracks in original borosilicate glass samples with a reproducible method (thermal treatment with a thermal shock of 300°C). The evolution of the elastic and transport properties have been monitored using elastic wave velocity sensors, strain gage, and flow measurements. The results obtained evidence for (1) a crack family with identified average aspect ratio and crack aperture, (2) a very small permeability which decreases as a power (exponential) function of pressure, and depends on (3) the crack aperture cube. We also show that permeability behavior of a cracked elastic brittle solid is reversible and independent of the fluid nature. Two independent methods (permeability and elastic wave velocity measurements) give these consistent results. This study provides data on the mechanical and transport properties of an almost ideal elastic brittle solid in which a crack population has been introduced. Comparisons with similar data on rocks allow for drawing interesting conclusions. Over the timescale of our experiments, our results do not provide any data on stress corrosion, which should be considered in further study.

  11. Dependence of optimal separative power of the “high-speed” Iguasu centrifuge on pressure of working gas

    NASA Astrophysics Data System (ADS)

    Bogovalov, S. V.; Borman, V. D.; Borisevich, V. D.; Davidenko, O. V.; Tronin, I. V.; Tronin, V. N.

    2016-09-01

    The results of optimization calculations of the separative power of the ’’high-speed” Iguasu gas centrifuge are presented. Iguasu gas centrifuge has the rotational speed of 1000 m/s, the rotor length of 1 m. The dependence of the optimal separative power on the pressure of the working gas on the rotor wall was obtained using the numerical simulations. It is shown, that maximum of the optimal separative power corresponds to the pressure of 1100 mmHg. Maximum value of separative power is 31.9 SWU.

  12. [Associations of the work duration, sleep duration and number of holidays with an exaggerated blood pressure response during an exercise stress test among workers].

    PubMed

    Michishita, Ryoma; Ohta, Masanori; Ikeda, Masaharu; Jiang, Ying; Yamato, Hiroshi

    2016-01-01

    It has been reported that an exaggerated systolic blood pressure (ESBP) response during exercise, even if resting blood pressure is normal, is associated with an increased risk of future hypertension and cardiovascular disease (CVD). This study was designed to investigate the relationships of work duration, sleep duration and number of holidays with blood pressure response during an exercise stress test among normotensive workers. The subjects were 362 normotensive workers (79 males and 283 females; age, 49.1 years). A multi-stage graded submaximal exercise stress test was performed on each subject using an electric bicycle ergometer. The workload was increased every 3 minutes, and blood pressure was measured at rest and during the last 1 minute of each stage. In this study, an ESBP response during exercise was defined according to the criteria of the Framingham Study (peak systolic blood pressure ≥210 mmHg in males, or ≥190 mmHg in females). Working environments, work duration, sleep duration, number of holidays, and physical activity during commuting and work, and leisure time exercise duration were evaluated using a questionnaire. An ESBP response during exercise was observed in 94 (26.0%) workers. The adjusted odds ratio for the prevalence of an ESBP response during exercise was found to be significantly higher with an increase in work duration, decreases in sleep duration and number of holidays (p<0.05, respectively). Moreover, the highest work duration with lowest sleep duration and number of holidays groups had significantly higher adjusted odds ratio for the prevalence of an ESBP response during exercise than the lowest work duration with highest sleep duration and number of holidays groups (p<0.05, respectively). Based on our results, we consider that the assessment of blood pressure response during exercise and daily life are necessary to prevent the incidence of future hypertension, CVD and death due to overwork in workers with long-work duration

  13. Miniaturized pressurization system

    DOEpatents

    Whitehead, John C.; Swink, Don G.

    1991-01-01

    The invention uses a fluid stored at a low pressure and provides the fluid at a high pressure. The invention allows the low pressure fluid to flow to a fluid bore of a differential pump and from the pump to a fluid pressure regulator. After flowing through the regulator the fluid is converted to a gas which is directed to a gas bore of the differential pump. By controlling the flow of gas entering and being exhausted from the gas bore, the invention provides pressure to the fluid. By setting the regulator, the high pressure fluid can be set at predetermined values. Because the invention only needs a low pressure fluid, the inventive apparatus has a low mass, and therefore would be useful in rocket propulsion systems.

  14. How much work is expended for respiration?

    PubMed

    Johnson, A T

    1993-01-01

    The rate of work expended to move air in the respiratory system has been determined for five different airflow waveshapes, a non-linear respiratory model and five exercise levels. As expected, the rectangular waveshape was the most efficient. Model conditions were then changed one a time: (i) starting lung volume was allowed to vary, (ii) exhalation flow limitation was added, (iii) respiration was considered to be a metabolic burden determining part of the ventilation requirement and (iv) a respirator mask was added. Although there is no direct work advantage to varying initial lung volume, such volume changes appear to be dictated by the asymmetry of lung recoil pressure about the lung relaxation volume; allowing the work of respiration to become a metabolic burden clearly shows why respiratory waveforms change from rest to exercise; and, adding a respirator imposes a severe respiratory burden on the wearer engaging in moderate, heavy and very heavy exercise.

  15. The effect of working gas pressure on the switching rate of a kivotron

    NASA Astrophysics Data System (ADS)

    Bokhan, P. A.; Gugin, P. P.; Zakrevsky, D. E.; Lavrukhin, M. A.

    2016-05-01

    The switching rate in gas-discharge devices (kivotrons) based on an "open" discharge with counterpropagating electron beams is studied experimentally. Structures with a total cathode area of 2 cm2 were used. A monotonic reduction in the switching time with an increase in the working gas pressure and in the voltage amplitude at the time of breakdown is demonstrated. The minimum switching time is ~240 ps at a voltage of 17 kV. The maximum current rise rate, which is limited by the discharge circuit inductance, is 3 × 1012 A/s.

  16. Development of a Numerical Model of Hypervelocity Impact into a Pressurized Composite Overwrapped Pressure Vessel

    NASA Technical Reports Server (NTRS)

    Garcia, M. A.; Davis, B. A.; Miller, J. E.

    2017-01-01

    considered a catastrophic failure. This assumption is conservative and made due to lack of knowledge on the level of allow-able damage to the composite overwrap that can be sustained and still allow successful completion of the mission. To quantify the allowable damage level to the composite overwrap involves assessing stress redistribution following damage as well as evaluating possible time-dependent mechanisms involved in the COPV response to an impact event. Limited published work in this subject has shown that COPV can withstand at least some level of damage due to high energy impacts. These observations have been confirmed and expanded upon in recent experimental research performed by NASA. This research has demonstrated that there is not only robustness in a COPV to compensate for CFRP damage, but has also identified two significant failure modes for pressurized COPV. The lowest threshold failure mode involves the perforation of the vessel, and the highest threshold failure mode is the catastrophic rupture. While both of these failure modes mean a loss of the COPV, system robustness affords some tolerance to the venting as opposed to the more catastrophic rupture. As a consequence, it is necessary to understand the conditions that result in the transition between these failure modes. The aforementioned experimental research has been performed in both the unpressurized and pressurized condition to identify the damage level that triggered the failure thresh-old. This COPV test program was sponsored by the NASA Engineering and Safety Center (NESC), and tests were performed at NASA White Sands Test Facility (WSTF). Planning and coordination were provided by NASA JSC Hypervelocity Impact Technology (HVIT) group, and the COPVs were provided by the ISS Program. Unpressurized testing has been conducted at the pressure of the vacuum test chamber, while, the pressurized testing has been conducted at 290 +/- 10 bar (4,200 ? 100 psi) using nitrogen as the pressurizing gas, which

  17. Dynamic Pressure Probes Developed for Supersonic Flow-Field Measurements

    NASA Technical Reports Server (NTRS)

    Porro, A. Robert

    2001-01-01

    A series of dynamic flow-field pressure probes were developed for use in large-scale supersonic wind tunnels at the NASA Glenn Research Center. These flow-field probes include pitot and static pressure probes that can capture fast-acting flow-field pressure transients occurring on a millisecond timescale. The pitot and static probes can be used to determine local Mach number time histories during a transient event. The flow-field pressure probe contains four major components: 1) Static pressure aerodynamic tip; 2) Pressure-sensing cartridge assembly; 3) Pitot pressure aerodynamic tip; 4) Mounting stem. This modular design allows for a variety of probe tips to be used for a specific application. Here, the focus is on flow-field pressure measurements in supersonic flows, so we developed a cone-cylinder static pressure tip and a pitot pressure tip. Alternatively, probe tips optimized for subsonic and transonic flows could be used with this design. The pressure-sensing cartridge assembly allows the simultaneous measurement of steady-state and transient pressure which allows continuous calibration of the dynamic pressure transducer.

  18. [Device to assess in-socket pressure distribution for partial foot amputation].

    PubMed

    Alvarez-Camacho, Michelín; Urrusti, José Luis; Acero, María Del Carmen; Galván Duque-Gastélum, Carlos; Rodríguez-Reyes, Gerardo; Mendoza-Cruz, Felipe

    2014-07-01

    A device for dynamic acquisition and distribution analysis of in-socket pressure for patients with partial foot amputation is presented in this work. By using the developed system, we measured and generated pressure distribution graphs, obtained maximal pressure, and calculated pressure-time integral (PTI) of three subjects with partial foot amputation and of a group of Healthy subjects (Hs) (n = 10). Average maximal pressure in the healthy group was 19.4 ± 4.11 PSI, while for the three amputated patients, this was 27.8 ± 1.38, 17.6 ± 1.15, 29.10 ± 3.9 PSI, respectively. Maximal pressure-time integral for healthy subjects was 11.56 ± 2.83 PSI*s, and for study subjects was 19.54 ± 1.9, 12.35 ± 1.48, and 13.17 ± 1.31 PSI*s, respectively. The results of the control group agree with those previously reported in the literature. The pressure distribution pattern showed clear differences between study subjects and those of the control group; these graphs allowed us to identify the pressure in regions-of-interest that could be critical, such as surgical scars. The system presented in this work will aid to assess the effectiveness with which prosthetic systems distribute load, given that the formation of ulcers is highly linked to the pressure exercised at the point of contact; in addition, these results will help to investigate the comfort perception of the prosthesis, a factor directly influenced by the stump's pressure distribution.

  19. 20 CFR 664.470 - Are paid work experiences allowable activities?

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... LABOR YOUTH ACTIVITIES UNDER TITLE I OF THE WORKFORCE INVESTMENT ACT Youth Program Design, Elements, and... where the objective assessment and individual service strategy indicate that work experiences are...

  20. Is It Safe to Allow Cell Phones in School?

    ERIC Educational Resources Information Center

    Trump, Kenneth S.

    2009-01-01

    Cell phones were banned from most schools years ago, but after the Columbine High School and 9/11 tragedies, parents started pressuring some school boards and administrators to reverse the bans. On its surface, allowing students to have cell phones under the guise of improved school safety may seem like a "no-brainer" to many board members and…

  1. Improvement of technical purpose materials performance characteristics with the radio frequency low pressure plasma

    NASA Astrophysics Data System (ADS)

    Makhotkina, L. Yu; Khristoliubova, V. I.

    2017-11-01

    The main aim of the work is to solve the actual problem of increasing the competitiveness of tanning products by reducing the prime cost and improving the quality of finished products due to the increased durability of the working elements of tanneries. The impact of the low pressure radio frequency (RF) plasma in the processes of treating for modification of the materials for special purposes is considered in the article. The results of working elements of tanneries and the materials for special purposes sample processing by a RF low pressure plasma are described. As a result of leather materials nano structuring and nano modifying physical, mechanical and hygienic characteristics were increased. Processing of the technical purpose materials allows to increase operational performance of products and extend their lifespan.

  2. Analysis and Testing of a Metallic Repair Applicable to Pressurized Composite Aircraft Structure

    NASA Technical Reports Server (NTRS)

    Przekop, Adam; Jegley, Dawn C.; Rouse, Marshall; Lovejoy, Andrew E.

    2014-01-01

    Development of repair technology is vital to the long-term application of new structural concepts on aircraft structure. The design, analysis, and testing of a repair concept applicable to a stiffened composite panel based on the Pultruded Rod Stitched Efficient Unitized Structure was recently completed. The damage scenario considered was a mid-bay to mid-bay saw-cut with a severed stiffener, flange, and skin. A bolted metallic repair was selected so that it could be easily applied in the operational environment. The present work describes results obtained from tension and pressure panel tests conducted to validate both the repair concept and finite element analysis techniques used in the design effort. Simulation and experimental strain and displacement results show good correlation, indicating that the finite element modeling techniques applied in the effort are an appropriate compromise between required fidelity and computational effort. Static tests under tension and pressure loadings proved that the proposed repair concept is capable of sustaining load levels that are higher than those resulting from the current working stress allowables. Furthermore, the pressure repair panel was subjected to 55,000 pressure load cycles to verify that the design can withstand a life cycle representative for a transport category aircraft. These findings enable upward revision of the stress allowables that had been kept at an overly-conservative level due to concerns associated with repairability of the panels. This conclusion enables more weight efficient structural designs utilizing the composite concept under investigation.

  3. Pressure-Directed Assembly: Nanostructures Made Easy

    NASA Astrophysics Data System (ADS)

    Fan, Hongyou

    Precise control of structural parameters through nanoscale engineering to improve optical and electronic properties of functional nanomaterials continuously remains an outstanding challenge. Previous work has been conducted largely at ambient pressure and relies on specific chemical or physical interactions such as van der Waals interactions, dipole-dipole interactions, chemical reactions, ligand-receptor interactions, etc. In this presentation, I will introduce a new pressure-directed assembly method that uses mechanical compressive force applied to nanoparticle arrays to induce structural phase transition and to consolidate new nanomaterials with precisely controlled structures and tunable properties. By manipulating nanoparticle coupling through external pressure, instead of through chemistry, a reversible change in their assemblies and properties can be achieved and demonstrated. In addition, over a certain threshold, the external pressure will force these nanoparticles into contact, thereby allowing the formation and consolidation of one- to three-dimensional nanostructures. Through pressure induced nanoparticle assembly, materials engineering and synthesis become remarkably flexible without relying on traditional crystallization process where atoms/ions are locked in a specific crystal structure. Therefore, morphology or architecture can be readily tuned to produce desirable properties for practical applications. Sandia National Laboratories is a multi-program laboratory managed and operated by Sandia Corporation, a wholly owned subsidiary of Lockheed Martin Corporation, for the U.S. Department of Energy's National Nuclear Security Administration under Contract DE-AC04-94AL85000.

  4. From Poor Performance to Success under Stress: Working Memory, Strategy Selection, and Mathematical Problem Solving under Pressure

    ERIC Educational Resources Information Center

    Beilock, Sian L.; DeCaro, Marci S.

    2007-01-01

    Two experiments demonstrate how individual differences in working memory (WM) impact the strategies used to solve complex math problems and how consequential testing situations alter strategy use. In Experiment 1, individuals performed multistep math problems under low- or high-pressure conditions and reported their problem-solving strategies.…

  5. Laser Scanning System for Pressure and Temperature Paints

    NASA Technical Reports Server (NTRS)

    Sullivan, John

    1997-01-01

    Acquiring pressure maps of aerodynamic surfaces is very important for improving and validating the performance of aerospace vehicles. Traditional pressure measurements are taken with pressure taps embedded in the model surface that are connected to transducers. While pressure taps allow highly accurate measurements to be acquired, they do have several drawbacks. Pressure taps do not give good spatial resolution due to the need for individual pressure tubes, compounded by limited space available inside models. Also, building a model proves very costly if taps are needed because of the large amount of labor necessary to drill, connect and test each one. The typical cost to install one tap is about $200. Recently, a new method for measuring pressure on aerodynamic surfaces has been developed utilizing a technology known as pressure sensitive paints (PSP). Using PSP, pressure distributions can be acquired optically with high spatial resolution and simple model preparation. Flow structures can be easily visualized using PSP, but are missed using low spatial resolution arrays of pressure taps. PSP even allows pressure distributions to be found on rotating machinery where previously this has been extremely difficult or even impossible. The goal of this research is to develop a laser scanning system for use with pressure sensitive paints that allows accurate pressure measurements to be obtained on various aerodynamic surfaces ranging from wind tunnel models to high speed jet engine compressor blades.

  6. Influence of pressure and temperature on molar volume and retention properties of peptides in ultra-high pressure liquid chromatography.

    PubMed

    Fekete, Szabolcs; Horváth, Krisztián; Guillarme, Davy

    2013-10-11

    In this study, pressure induced changes in retention were measured for model peptides possessing molecular weights between ∼1 and ∼4kDa. The goal of the present work was to evaluate if such changes were only attributed to the variation of molar volume and if they could be estimated prior to the experiments, using theoretical models. Restrictor tubing was employed to generate pressures up to 1000bar and experiments were conducted for mobile phase temperatures comprised between 30 and 80°C. As expected, the retention increases significantly with pressure, up to 200% for glucagon at around 1000bar compared to ∼100bar. The obtained data were fitted with a theoretical model and the determination coefficients were excellent (r(2)>0.9992) for the peptides at various temperatures. On the other hand, the pressure induced change in retention was found to be temperature dependent and was more pronounced at 30°C vs. 60 or 80°C. Finally, using the proposed model, it was possible to easily estimate the pressure induced increase in retention for any peptide and mobile phase temperature. This allows to easily estimating the expected change in retention, when increasing the column length under UHPLC conditions. Copyright © 2013 Elsevier B.V. All rights reserved.

  7. Influence of gas law on ultrasonic behaviour of porous media under pressure.

    PubMed

    Griffiths, S; Ayrault, C

    2010-06-01

    This paper deals with the influence of gas law on ultrasonic behaviour of porous media when the saturating fluid is high pressured. Previous works have demonstrated that ultrasonic transmission through a porous sample with variations of the static pressure (up to 18 bars) of the saturating fluid allows the characterization of high damping materials. In these studies, the perfect gas law was used to link static pressure and density, which is disputable for high pressures. This paper compares the effects of real and perfect gas laws on modeled transmission coefficient for porous foams at these pressures. Direct simulations and a mechanical parameters estimation from minimization show that results are very similar in both cases. The real gas law is thus not necessary to describe the acoustic behaviour of porous media at low ultrasonic frequencies (100 kHz) up to 20 bars. 2010 Elsevier B.V. All rights reserved.

  8. Pressure ratio effects on self-similar scalar mixing of high-pressure turbulent jets in a pressurized volume

    NASA Astrophysics Data System (ADS)

    Ruggles, Adam; Pickett, Lyle; Frank, Jonathan

    2014-11-01

    Many real world combustion devices model fuel scalar mixing by assuming the self-similar argument established in atmospheric free jets. This allows simple prediction of the mean and rms fuel scalar fields to describe the mixing. This approach has been adopted in super critical liquid injections found in diesel engines where the liquid behaves as a dense fluid. The effect of pressure ratio (injection to ambient) when the ambient is greater than atmospheric pressure, upon the self-similar collapse has not been well characterized, particularly the effect upon mixing constants, jet spreading rates, and virtual origins. Changes in these self-similar parameters control the reproduction of the scalar mixing statistics. This experiment investigates the steady state mixing of high pressure ethylene jets in a pressurized pure nitrogen environment for various pressure ratios and jet orifice diameters. Quantitative laser Rayleigh scattering imaging was performed utilizing a calibration procedure to account for the pressure effects upon scattering interference within the high-pressure vessel.

  9. Revealing nanoparticle assembly under high pressure.

    NASA Astrophysics Data System (ADS)

    Fan, Hongyou

    Precise control of structural parameters through nanoscale engineering to improve optical and electronic properties of functional nanoparticles continuously remains an outstanding challenge. Previous work on nanoparticle assembly has been conducted largely at ambient pressure. Here I will present a new Stress-Induced Fabrication method in which we applied high pressure or stress to nanoparticle arrays to induce structural phase transition and to consolidate new nanomaterials with precisely controlled structures and tunable properties. By manipulating nanoparticle coupling through external pressure, a reversible change in their assemblies and properties can be achieved and demonstrated. In addition, over a certain threshold, the external pressure will force these nanoparticles into contact, thereby allowing the formation and consolidation of one- to three-dimensional nanostructures. Through stress induced nanoparticle assembly, materials engineering and synthesis become remarkably flexible without relying on traditional crystallization process where atoms/ions are locked in a specific crystal structure. Therefore, morphology or architecture can be readily tuned to produce desirable properties for practical applications. Sandia National Laboratories is a multi-mission laboratory managed and operated by Sandia Corporation, a wholly owned subsidiary of Lockheed Martin Corporation, for the U.S. Department of Energy's National Nuclear Security Administration under contract DE-AC04-94AL85000.

  10. Pressure independence of granular flow through an aperture.

    PubMed

    Aguirre, M A; Grande, J G; Calvo, A; Pugnaloni, L A; Géminard, J-C

    2010-06-11

    We experimentally demonstrate that the flow rate of granular material through an aperture is controlled by the exit velocity imposed on the particles and not by the pressure at the base, contrary to what is often assumed in previous work. This result is achieved by studying the discharge process of a dense packing of monosized disks through an orifice. The flow is driven by a conveyor belt. This two-dimensional horizontal setup allows us to independently control the velocity at which the disks escape the horizontal silo and the pressure in the vicinity of the aperture. The flow rate is found to be proportional to the belt velocity, independent of the amount of disks in the container and, thus, independent of the pressure in the outlet region. In addition, this specific configuration makes it possible to get information on the system dynamics from a single image of the disks that rest on the conveyor belt after the discharge.

  11. Subjective time pressure: general or domain specific?

    PubMed

    Kleiner, Sibyl

    2014-09-01

    Chronic time pressure has been identified as a pervasive societal problem, exacerbated by high demands of the labor market and the home. Yet time pressure has not been disaggregated and examined separately across home and work contexts, leaving many unanswered questions regarding the sources and potentially stressful consequences of time pressure. Using data collected in the United States General Social Survey waves 2002 and 2004, this study disaggregates time pressure into the domains of home and work, and asks whether considering time pressures within distinct work and home contexts reveals distinct predictors or associations with stress. Findings show that both predictors and stress associations differ across work and home pressures, revealing both methodological and theoretical implications for the study of time pressure and work and family life more generally. Copyright © 2014 Elsevier Inc. All rights reserved.

  12. Functional Sub-states by High-pressure Macromolecular Crystallography.

    PubMed

    Dhaussy, Anne-Claire; Girard, Eric

    2015-01-01

    At the molecular level, high-pressure perturbation is of particular interest for biological studies as it allows trapping conformational substates. Moreover, within the context of high-pressure adaptation of deep-sea organisms, it allows to decipher the molecular determinants of piezophily. To provide an accurate description of structural changes produced by pressure in a macromolecular system, developments have been made to adapt macromolecular crystallography to high-pressure studies. The present chapter is an overview of results obtained so far using high-pressure macromolecular techniques, from nucleic acids to virus capsid through monomeric as well as multimeric proteins.

  13. Assessment Data at Your Fingertips: Advances Allow for Timely Reporting

    ERIC Educational Resources Information Center

    Bolch, Matt

    2009-01-01

    The ever-increasing standards of No Child Left Behind regulations and various state assessments have put more pressure on teachers and administrators to monitor the learning process. Fortunately, the advent of technology is allowing teachers to test more often to prepare students for high-stakes tests and for districts to understand results for…

  14. Neural Network Burst Pressure Prediction in Composite Overwrapped Pressure Vessels

    NASA Technical Reports Server (NTRS)

    Hill, Eric v. K.; Dion, Seth-Andrew T.; Karl, Justin O.; Spivey, Nicholas S.; Walker, James L., II

    2007-01-01

    Acoustic emission data were collected during the hydroburst testing of eleven 15 inch diameter filament wound composite overwrapped pressure vessels. A neural network burst pressure prediction was generated from the resulting AE amplitude data. The bottles shared commonality of graphite fiber, epoxy resin, and cure time. Individual bottles varied by cure mode (rotisserie versus static oven curing), types of inflicted damage, temperature of the pressurant, and pressurization scheme. Three categorical variables were selected to represent undamaged bottles, impact damaged bottles, and bottles with lacerated hoop fibers. This categorization along with the removal of the AE data from the disbonding noise between the aluminum liner and the composite overwrap allowed the prediction of burst pressures in all three sets of bottles using a single backpropagation neural network. Here the worst case error was 3.38 percent.

  15. Implantable blood pressure sensor for analyzing elasticity in arteries

    NASA Astrophysics Data System (ADS)

    Franco-Ayala, Marco; Martínez-Piñón, Fernando; Reyes-Barranca, Alfredo; Sánchez de la Peña, Salvador; Álvarez-Chavez, José A.

    2009-03-01

    MEMS technology could be an option for the development of a pressure sensor which allows the monitoring of several electronic signals in humans. In this work, a comparison is made between the typical elasticity curves of several arteries in the human body and the elasticity obtained for MEMS silicon microstructures such as membranes and cantilevers employing Finite Element analysis tools. The purpose is to identify which types of microstructures are mechanically compatible with human arteries. The goal is to integrate a blood pressure sensor which can be implanted in proximity with an artery. The expected benefits for this type of sensor are mainly to reduce the problems associated with the use of bulk devices through the day and during several days. Such a sensor could give precise blood pressure readings in a continuous or periodic form, i.e. information that is especially important for some critical cases of hypertension patients.

  16. Volumetric Deformation of Live Cells Induced by Pressure-Activated Cross-Membrane Ion Transport

    NASA Astrophysics Data System (ADS)

    Hui, T. H.; Zhou, Z. L.; Qian, J.; Lin, Y.; Ngan, A. H. W.; Gao, H.

    2014-09-01

    In this work, we developed a method that allows precise control over changes in the size of a cell via hydrostatic pressure changes in the medium. Specifically, we show that a sudden increase, or reduction, in the surrounding pressure, in the physiologically relevant range, triggers cross-membrane fluxes of sodium and potassium ions in leukemia cell lines K562 and HL60, resulting in reversible volumetric deformation with a characteristic time of around 30 min. Interestingly, healthy leukocytes do not respond to pressure shocks, suggesting that the cancer cells may have evolved the ability to adapt to pressure changes in their microenvironment. A model is also proposed to explain the observed cell deformation, which highlights how the apparent viscoelastic response of cells is governed by the microscopic cross-membrane transport.

  17. Assessment of the accuracy of pharmacy students' compounded solutions using vapor pressure osmometry.

    PubMed

    Kolling, William M; McPherson, Timothy B

    2013-04-12

    OBJECTIVE. To assess the effectiveness of using a vapor pressure osmometer to measure the accuracy of pharmacy students' compounding skills. DESIGN. Students calculated the theoretical osmotic pressure (mmol/kg) of a solution as a pre-laboratory exercise, compared their calculations with actual values, and then attempted to determine the cause of any errors found. ASSESSMENT. After the introduction of the vapor pressure osmometer, the first-time pass rate for solution compounding has varied from 85% to 100%. Approximately 85% of students surveyed reported that the instrument was valuable as a teaching tool because it objectively assessed their work and provided immediate formative assessment. CONCLUSIONS. This simple technique of measuring compounding accuracy using a vapor pressure osmometer allowed students to see the importance of quality control and assessment in practice for both pharmacists and technicians.

  18. Treatment of sleep-disordered breathing with positive airway pressure devices: technology update.

    PubMed

    Johnson, Karin Gardner; Johnson, Douglas Clark

    2015-01-01

    Many types of positive airway pressure (PAP) devices are used to treat sleep-disordered breathing including obstructive sleep apnea, central sleep apnea, and sleep-related hypoventilation. These include continuous PAP, autoadjusting CPAP, bilevel PAP, adaptive servoventilation, and volume-assured pressure support. Noninvasive PAP has significant leak by design, which these devices adjust for in different manners. Algorithms to provide pressure, detect events, and respond to events vary greatly between the types of devices, and vary among the same category between companies and different models by the same company. Many devices include features designed to improve effectiveness and patient comfort. Data collection systems can track compliance, pressure, leak, and efficacy. Understanding how each device works allows the clinician to better select the best device and settings for a given patient. This paper reviews PAP devices, including their algorithms, settings, and features.

  19. High Pressure/Temperature Metal Silicate Partitioning of Tungsten

    NASA Technical Reports Server (NTRS)

    Shofner, G. A.; Danielson, L.; Righter, K.; Campbell, A. J.

    2010-01-01

    The behavior of chemical elements during metal/silicate segregation and their resulting distribution in Earth's mantle and core provide insight into core formation processes. Experimental determination of partition coefficients allows calculations of element distributions that can be compared to accepted values of element abundances in the silicate (mantle) and metallic (core) portions of the Earth. Tungsten (W) is a moderately siderophile element and thus preferentially partitions into metal versus silicate under many planetary conditions. The partitioning behavior has been shown to vary with temperature, silicate composition, oxygen fugacity, and pressure. Most of the previous work on W partitioning has been conducted at 1-bar conditions or at relatively low pressures, i.e. <10 GPa, and in two cases at or near 20 GPa. According to those data, the stronger influences on the distribution coefficient of W are temperature, composition, and oxygen fugacity with a relatively slight influence in pressure. Predictions based on extrapolation of existing data and parameterizations suggest an increased pressured dependence on metal/ silicate partitioning of W at higher pressures 5. However, the dependence on pressure is not as well constrained as T, fO2, and silicate composition. This poses a problem because proposed equilibration pressures for core formation range from 27 to 50 GPa, falling well outside the experimental range, therefore requiring exptrapolation of a parametereized model. Higher pressure data are needed to improve our understanding of W partitioning at these more extreme conditions.

  20. 40 CFR 35.2025 - Allowance and advance of allowance.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... advance of allowance. (a) Allowance. Step 2+3 and Step 3 grant agreements will include an allowance for facilities planning and design of the project and Step 7 agreements will include an allowance for facility... 40 Protection of Environment 1 2010-07-01 2010-07-01 false Allowance and advance of allowance. 35...

  1. Elastomeric Sensing of Pressure with Liquid Metal and Wireless Inductive Coupling

    NASA Technical Reports Server (NTRS)

    Dick, Jacob; Zou, Xiyue; Hogan, Ben; Tumalle, Jonathan; Etikyala, Sowmith; Fung, Diego; Charles, Watley; Gu, Tianye; Hull, Patrick V.; Mazzeo, Aaron D.

    2017-01-01

    This project describes resistance-based soft sensors filled with liquid metal, which permit measurements of large strains (0 percent to 110 percent), associated with small forces of less than 30 Newtons. This work also demonstrates a methodology for wireless transfer of these strain measurements without connected electrodes. These sensors allow intermittent detection of pressure on soft membranes with low force. Adapting these sensors for passive wireless pressure sensing will eliminate the need for embedded batteries, and will allow the sensors to transmit pressure data through non-conductive materials including glass and acrylic. The absence of batteries allows us to embed these sensors into materials for long-term use because the sensors only use passive analog circuit elements. We found the oxidation of the liquid metal (eutectic gallium indium) plays a role in the repeatability of the soft sensors. We investigated how the oxidation layer affected the behavior of the sensor by encapsulating materials (silicone, fluorosilicone, and PVC) with varied permeabilities to oxygen. We measured the effects of mechanical loading on the oxidation layer and the effects of wireless inductive coupling on the oxidation layer. We concluded our research by investigating the effects of embedding self-resonant circuits into polydimethylsiloxane (PDMS). Efforts to design engineered systems with soft materials are a growing field with progress in soft robotics, epidermal electronics, and wearable electronics. In the field of soft robotics, PDMS-based grippers are capable of picking up delicate objects because their form-fitting properties allow them to conform to the shape of objects more easily than conventional robotic grippers. Epidermal devices also use PDMS as a substrate to hold electronic components such as radios, sensors, and power supply circuits. Additionally, PDMS-based soft sensors can monitor human motion with liquid metal embedded within micro-channels. Passive

  2. Does Psychosocial Work Environment Factors Predict Stress and Mean Arterial Pressure in the Malaysian Industry Workers?

    PubMed

    Javaid, Muhammad Umair; Isha, Ahmad Shahrul Nizam; Sabir, Asrar Ahmed; Ghazali, Zulkipli; Nübling, Matthias

    2018-01-01

    Psychosocial risks are considered as a burning issue in the Asia-Pacific region. The aim of this study was to investigate the impact of psychosocial work environment factors on health of petrochemical industry workers of Malaysia. In lieu to job demands-resources theory, significant positive associations were found between quantitative demands, work-family conflict, and job insecurity with stress, while a significant negative association of role clarity as a resource factor with stress was detected. We also found that quantitative demands were significantly associated with the mean arterial pressure (MAP). Multistage sampling procedure was used to collect study sample. Structural Equation Modeling was used to identify relationship between the endogenous and exogenous variables. Finally, the empirically tested psychosocial work environment model will further help in providing a better risk assessment in different industries and enterprises.

  3. Effect of working pressure on corrosion behavior of nitrogen doped diamond-like carbon thin films deposited by DC magnetron sputtering.

    PubMed

    Khun, N W; Liu, E

    2011-06-01

    Nitrogen doped diamond-like carbon thin films were deposited on highly conductive p-silicon(100) substrates using a DC magnetron sputtering deposition system by varying working pressure in the deposition chamber. The bonding structure, adhesion strength, surface roughness and corrosion behavior of the films were investigated by using X-ray photoelectron spectroscopy, micro-Raman spectroscopy, micro-scratch test, atomic force microscopy and potentiodynamic polarization test. A 0.6 M NaCl electrolytic solution was used for the corrosion tests. The optimum corrosion resistance of the films was found at a working pressure of 7 mTorr at which a good balance between the kinetics of the sputtered ions and the surface mobility of the adatoms promoted a microstructure of the films with fewer porosities.

  4. A miniature 48-channel pressure sensor module capable of in situ calibration

    NASA Technical Reports Server (NTRS)

    Gross, C.; Juanarena, D. B.

    1977-01-01

    A new high data rate pressure sensor module with in situ calibration capability has been developed by the Langley Research Center to help reduce energy consumption in wind-tunnel facilities without loss of measurement accuracy. The sensor module allows for nearly a two order of magnitude increase in data rates over conventional electromechanically scanned pressure sampling techniques. This module consists of 16 solid state pressure sensor chips and signal multiplexing electronics integrally mounted to a four position pressure selector switch. One of the four positions of the pressure selector switch allows the in situ calibration of the 16 pressure sensors; the three other positions allow 48 channels (three sets of 16) pressure inputs to be measured by sensors. The small size of the sensor module will allow mounting within many wind-tunnel models, thus eliminating long tube lengths and their corresponding slow pressure response.

  5. Estimation of turgor pressure through comparison between single plant cell and pressurized shell mechanics

    NASA Astrophysics Data System (ADS)

    Durand-Smet, P.; Gauquelin, E.; Chastrette, N.; Boudaoud, A.; Asnacios, A.

    2017-10-01

    While plant growth is well known to rely on turgor pressure, it is challenging to quantify the contribution of turgor pressure to plant cell rheology. Here we used a custom-made micro-rheometer to quantify the viscoelastic behavior of isolated plant cells while varying their internal turgor pressure. To get insight into how plant cells adapt their internal pressure to the osmolarity of their medium, we compared the mechanical behavior of single plant cells to that of a simple, passive, pressurized shell: a soccer ball. While both systems exhibited the same qualitative behavior, a simple mechanical model allowed us to quantify turgor pressure regulation at the single cell scale.

  6. Pressure cryocooling protein crystals

    DOEpatents

    Kim, Chae Un [Ithaca, NY; Gruner, Sol M [Ithaca, NY

    2011-10-04

    Preparation of cryocooled protein crystal is provided by use of helium pressurizing and cryocooling to obtain cryocooled protein crystal allowing collection of high resolution data and by heavier noble gas (krypton or xenon) binding followed by helium pressurizing and cryocooling to obtain cryocooled protein crystal for collection of high resolution data and SAD phasing simultaneously. The helium pressurizing is carried out on crystal coated to prevent dehydration or on crystal grown in aqueous solution in a capillary.

  7. 24 CFR 17.43 - Allowable claims.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... local inhabitant; or (iii) Any warehouse, office, working area, or other place (except quarters... carrier, an agent or agency of the Government, or the claimant. (3) Manufactured homes. Claims may be allowed for damage to, or loss of, manufactured homes and their contents under the provisions of paragraph...

  8. Pressure effects on the electronic properties in CeCoIn5: A first-principle study

    NASA Astrophysics Data System (ADS)

    Medeiros, Gustavo; Gonzalez, J. L.; Scopel, Wanderlã L.

    2017-11-01

    Superconducting heavy fermions are exotic materials with strong electronic correlations. The temperature-pressure phase diagrams of some of these materials show a complex interplay between superconductivity and magnetism that is essential to understand the physical properties of these systems. In this work, first principle calculations are performed in order to study the pressure effects on the electronic correlations in the CeCoIn5 system, which is superconducting at ambient pressure with Tc = 2.3 K. The density functional theory (DFT) method was used to include on-site coulomb repulsions (U) at the d (Co and In) and f (Ce) electrons of the CeCoIn5 compound. External applied pressures were simulated by correlating an applied pressure with a reduction of the volume of the unit cell, but keeping constant the c/a relation, as reported in experiments. Our findings reveal that the U parameters for all atomic species increase linearly with the pressure (P), being this effect higher for the f-electrons of the cerium ions, where dU / dP = 1.2 eV/GPa. In summary, these results not only suggest that the pressure effect can be correlated with an increase in the electronic correlations in the CeCoIn5 compound, as also, the work allows quantify this effect.

  9. Ultrasonic Apparatus and Technique to Measure Changes in Intracranial Pressure

    NASA Technical Reports Server (NTRS)

    Yost, William T. (Inventor); Cantrell, John H. (Inventor)

    2002-01-01

    Changes in intracranial pressure can be measured dynamically and non-invasively by monitoring one or more cerebrospinal fluid pulsatile components. Pulsatile components such as systolic and diastolic blood pressures are partially transferred to the cerebrospinal fluid by way of blood vessels contained in the surrounding brain tissue and membrane. As intracranial pressure varies these cerebrospinal fluid pulsatile components also vary. Thus, intracranial pressure can be dynamically measured. Furthermore, use of acoustics allows the measurement to be completely non-invasive. In the preferred embodiment, phase comparison of a reflected acoustic signal to a reference signal using a constant frequency pulsed phase-locked-loop ultrasonic device allows the pulsatile components to be monitored. Calibrating the device by inducing a known change in intracranial pressure allows conversion to changes in intracranial pressure.

  10. Development of a Self-Sluicing Pressure Leaf Filter

    NASA Astrophysics Data System (ADS)

    Cousineau, Bernard L.; Lumsden, J. R.

    The cylindrical Kelly filter presses installed in the Ewarton Works "C" phase did not perform satisfactorily because of difficulties with head seals, locking rings, and shell retraction mechanisms. As rectification required major modifications, a concept of a press which did not require to be opened for sluicing was proposed. Test work of various sluicing and res lurrying spray arrangements was carried out, and this led to the design of a self-sluicing press which used the shell of an existing Kelly press with its main axis vertical. One press was converted by July 1972, and a development period started. Although initial operation was encouraging, effective sluicing could not be guaranteed after 30 shifts. Modifications to leaf spacing, spray rotational speed, spray slot width, feed pressure and pre-coat control by November 1973, however, allowed effective performance for all of the 800 hour canvas life. Advantages are: reduced operating and maintenance manpower, clean environment, and reduced maintenance cost. The use of 1st wash overflow for sluicing has reduced caustic soda and canvas consumption. Ewarton Works now has four converted self-sluicing presses, and arc converting five more, and Arvida Works plan the installation of one for tests on red pressing (blow-off filtration). A side benefit of the development was the study of the benefits of constant pressure overflow filtration.

  11. Microfabricated Nickel Based Sensors for Hostile and High Pressure Environments

    NASA Astrophysics Data System (ADS)

    Holt, Christopher Michael Bjustrom

    This thesis outlines the development of two platforms for integrating microfabricated sensors with high pressure feedthroughs for application in hostile high temperature high pressure environments. An application in oil well production logging is explored and two sensors were implemented with these platforms for application in an oil well. The first platform developed involved microfabrication directly onto a cut and polished high pressure feedthrough. This technique enables a system that is more robust than the wire bonded silicon die technique used for MEMS integration in pressure sensors. Removing wire bonds from the traditional MEMS package allows for direct interface of a microfabricated sensor with a hostile high pressure fluid environment which is not currently possible. During the development of this platform key performance metrics included pressure testing to 70MPa and temperature cycling from 20°C to 200°C. This platform enables electronics integration with a variety of microfabricated electrical and thermal based sensors which can be immersed within the oil well environment. The second platform enabled free space fabrication of nickel microfabricated devices onto an array of pins using a thick tin sacrificial layer. This technique allowed microfabrication of metal MEMS that are released by distances of 1cm from their substrate. This method is quite flexible and allows for fabrication to be done on any pin array substrate regardless of surface quality. Being able to place released MEMS sensors directly onto traditional style circuit boards, ceramic circuit boards, electrical connectors, ribbon cables, pin headers, or high pressure feedthroughs greatly improves the variety of possible applications and reduces fabrication costs. These two platforms were then used to fabricate thermal conductivity sensors that showed excellent performance for distinguishing between oil, water, and gas phases. Testing was conducted at various flow rates and performance of

  12. Work of breathing using different interfaces in spontaneous positive pressure ventilation: helmet, face-mask, and endotracheal tube.

    PubMed

    Oda, Shinya; Otaki, Kei; Yashima, Nozomi; Kurota, Misato; Matsushita, Sachiko; Kumasaka, Airi; Kurihara, Hutaba; Kawamae, Kaneyuki

    2016-08-01

    Noninvasive positive pressure ventilation (NPPV) using a helmet is expected to cause inspiratory trigger delay due to the large collapsible and compliant chamber. We compared the work of breathing (WOB) of NPPV using a helmet or a full face-mask with that of invasive ventilation by tracheal intubation. We used a lung model capable of simulating spontaneous breathing (LUNGOO; Air Water Inc., Japan). LUNGOO was set at compliance (C) = 50 mL/cmH2O and resistance (R) = 5 cmH2O/L/s for normal lung simulation, C = 20 mL/cmH2O and R = 5 cmH2O/L/s for restrictive lung, and C = 50 mL/cmH2O and R = 20 cmH2O/L/s for obstructive lung. Muscle pressure was fixed at 25 cmH2O and respiratory rate at 20 bpm. Pressure support ventilation and continuous positive airway pressure were performed with each interface placed on a dummy head made of reinforced plastic that was connected to LUNGOO. We tested the inspiratory WOB difference between the interfaces with various combinations of ventilator settings (positive end-expiratory pressure 5 cmH2O; pressure support 0, 5, and 10 cmH2O). In the normal lung and restrictive lung models, WOB decreased more with the face-mask than the helmet, especially when accompanied by the level of pressure support. In the obstructive lung model, WOB with the helmet decreased compared with the other two interfaces. In the mixed lung model, there were no significant differences in WOB between the three interfaces. NPPV using a helmet is more effective than the other interfaces for WOB in obstructive lung disease.

  13. Simultaneous velocity and pressure quantification using pressure-sensitive flow tracers in air

    NASA Astrophysics Data System (ADS)

    Zhang, Peng; Peterson, Sean; Porfiri, Maurizio

    2017-11-01

    Particle-based measurement techniques for assessing the velocity field of a fluid have advanced rapidly over the past two decades. Full-field pressure measurement techniques have remained elusive, however. In this work, we aim to demonstrate the possibility of direct simultaneous planar velocity and pressure measurement of a high speed aerodynamic flow by employing novel pressure-sensitive tracer particles for particle image velocimetry (PIV). Specifically, the velocity and pressure variations of an airflow through a converging-diverging channel are studied. Polystyrene microparticles embedded with a pressure-sensitive phosphorescent dye-platinum octaethylporphyrin (PtOEP)-are used as seeding particles. Due to the oxygen quenching effect, the emission lifetime of PtOEP is highly sensitive to the oxygen concentration, that is, the partial pressure of oxygen, in the air. Since the partial pressure of oxygen is linearly proportional to the air pressure, we can determine the air pressure through the phosphorescence emission lifetime of the dye. The velocity field is instead obtained using traditional PIV methods. The particles have a pressure resolution on the order of 1 kPa, which may be improved by optimizing the particle size and dye concentration to suit specific flow scenarios. This work was supported by the National Science Foundation under Grant Number CBET-1332204.

  14. Assessment of the Accuracy of Pharmacy Students’ Compounded Solutions Using Vapor Pressure Osmometry

    PubMed Central

    McPherson, Timothy B.

    2013-01-01

    Objective. To assess the effectiveness of using a vapor pressure osmometer to measure the accuracy of pharmacy students’ compounding skills. Design. Students calculated the theoretical osmotic pressure (mmol/kg) of a solution as a pre-laboratory exercise, compared their calculations with actual values, and then attempted to determine the cause of any errors found. Assessment. After the introduction of the vapor pressure osmometer, the first-time pass rate for solution compounding has varied from 85% to 100%. Approximately 85% of students surveyed reported that the instrument was valuable as a teaching tool because it objectively assessed their work and provided immediate formative assessment. Conclusions. This simple technique of measuring compounding accuracy using a vapor pressure osmometer allowed students to see the importance of quality control and assessment in practice for both pharmacists and technicians. PMID:23610476

  15. Does Psychosocial Work Environment Factors Predict Stress and Mean Arterial Pressure in the Malaysian Industry Workers?

    PubMed Central

    Isha, Ahmad Shahrul Nizam; Sabir, Asrar Ahmed; Ghazali, Zulkipli; Nübling, Matthias

    2018-01-01

    Psychosocial risks are considered as a burning issue in the Asia-Pacific region. The aim of this study was to investigate the impact of psychosocial work environment factors on health of petrochemical industry workers of Malaysia. In lieu to job demands-resources theory, significant positive associations were found between quantitative demands, work-family conflict, and job insecurity with stress, while a significant negative association of role clarity as a resource factor with stress was detected. We also found that quantitative demands were significantly associated with the mean arterial pressure (MAP). Multistage sampling procedure was used to collect study sample. Structural Equation Modeling was used to identify relationship between the endogenous and exogenous variables. Finally, the empirically tested psychosocial work environment model will further help in providing a better risk assessment in different industries and enterprises. PMID:29568773

  16. Interpreting ASME limits and philosophy in FEA of pressure vessel parts

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bezerra, L.M.; Cruz, J.R.B.; Miranda, C.A.J.

    1995-12-01

    In recent years there has been an effort to interpret finite element (FE) stress results on the light of the ASME B and PV rules and philosophy. Many task groups have issued guidelines on stress linearization and classifications. All those attempts have come up trying to cope modern FE techniques with the rules imposed by the ASME Code. This paper is an independent contribution to the Pressure Vessel Research Council (PVRC) groups which are studying the stress classification and the failure mechanism in a FE framework. This work tries to complement the interesting work by Hollinger and Hechmer presented inmore » the PVP-94 in Minneapolis. In that paper, the authors examined a typical support skirt and showed relations between the skirt collapse load obtained by finite element analysis and the loads allowed from the ASME stress limits. To complement such paper, in the present article, different skirt geometry configurations are analyzed. The configurations here investigated consist of similar support skirts but with different angles of attachments between cylinder and cone parts. It will be possible to observe the influence of the bending stress in the collapse load and its relation to the allowable loads inferred from the ASME limits. A pressure vessel with torispherical head under internal pressure is also examined. Using elastic and limit load FEA, the present paper determines the collapse loads of the configurations. It sets up the relations between these collapse loads, stress categories, and limits dictated by the ASME Code Subsection NB. On the light of NB rules and philosophy, this paper shows how different methods of stress assessment, classification, and limits may influence in the design of a pressure vessel.« less

  17. An underwater blood pressure measuring device.

    PubMed

    Sieber, Arne; Kuch, Benjamin; L'abbate, Antonio; Wagner, Matthias; Dario, Paolo; Bedini, Remo

    2008-09-01

    Measurement of arterial blood pressure is an important vital sign for monitoring the circulation. However, up to now no instrument has been available that enables the measurement of blood pressure underwater. The present paper details a novel, oscillometric, automatic digital blood pressure (BP) measurement device especially designed for this purpose. It consists mainly of analogue and digital electronics in a lexan housing that is rated to a depth of up to 200 metres' sea water, a cuff and a solenoid for inflation of the cuff with air supplied from a scuba tank. An integrated differential pressure sensor, exposed to the same ambient pressure as the cuff, allows accurate BP measurement. Calculation of systolic and diastolic pressures is based on the analysis of pressure oscillations recorded during the deflation. In hyperbaric chamber tests to pressures up to 405 kPa, BP measurements taken with the prototype were comparable to those obtained with established manual and automated methods. Swimming pool tests confirmed the correct functioning of the system underwater. The quality of the recorded pressure oscillations was very good even at 10 metres' fresh water, and allowed determination of diastolic and systolic pressure values. Based on these results we envisage that this device will lead to a better understanding of human cardiovascular physiology in underwater and hyperbaric environments.

  18. Occupational pressure-targeting organisational factors to ameliorate occupational dysfunction.

    PubMed

    Loh, Siew Yim; Than, Winn; Quek, Kia Fatt

    2011-12-01

    Chronic pressure at work has debilitating impact on healthcare employers (e.g. reduced productivity, high costs, poor patient care) and on female healthcare employees (e.g. sickness, dysfunction). This paper highlights relationship at work as the key occupational source of work-stress which is organisational in nature. A cross-sectional study (n = 230) was conducted using the Pressure Management Inventory on several female dominated health professions within a large public hospital. Analysis of variance was used to show relationship between sources and outcome of pressure. Linear regressions were used to predict which sources of pressure (IV) was linked to the outcomes of occupational pressure (DV). The number one source of occupational pressure is relationships at work (i.e. with supervisors), and not workload. 'Relationship' is also the key predictor of several negative outcomes of pressure at work. Analysis of variance showed significant differences in two sources of pressures, i.e. Workload (P = 0.04) and Home-work balance (P = 0.03). This paper provides insights into the occupational pressure of women health professionals by highlighting the organisational sources of pressure and the implications for preventing occupational dysfunction secondary to stress at work.

  19. Working in a danger zone: A qualitative study of Taiwanese nurses' work experiences in a negative pressure isolation ward.

    PubMed

    Chen, Shu-Ling; Chen, Kuei-Ling; Lee, Li-Hung; Yang, Cheng-I

    2016-07-01

    Hospital nurses are frontline health care workers in controlling the spread of infectious diseases. It is not known if nurses working in negative pressure isolation wards (NPIWs) are better prepared than before to safely care for patients with common infectious diseases. For this qualitative descriptive study, 10 nurses were interviewed in depth about their experiences caring for patients in an NPIW. Tape recordings were transcribed verbatim and analyzed by qualitative content analysis. The following 5 themes were identified: (1) complexity of patient care, (2) dissatisfaction with the quantity and quality of protective equipment, (3) shortage of nursing staff, (4) continued worries about being infected, and (5) sensitivity to self-protection. Our participants' anxiety and uncertainty about being infected in the NPIW were increased by the complexity of patients' health problems and organizational factors. To protect themselves against infection before and during patient care, participants also developed sensitivity to, concepts about, and strategies to improve self-protection. NPIW administrators should pay more attention to nurses' concerns about improving the NPIW working environment, supply good quality protective equipment, and provide appropriate psychologic support and ongoing education to ensure that nurses feel safe while working. This ongoing education should refresh and update nurses' knowledge about disease transmission, therefore decreasing unnecessary anxiety based on misunderstandings about becoming infected. Copyright © 2016 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  20. The Shuttle Orbital Maneuvering System P-V-T Propellant Quantity Gaging Accuracy and Leak Detection Allowance for Four Instrumentation Conditions

    NASA Technical Reports Server (NTRS)

    Duhon, D. D.

    1975-01-01

    The shuttle orbital maneuvering system (OMS) pressure-volume-temperature (P-V-T) propellant gaging module computes the quantity of usable OMS propellant remaining based on the real gas P-V-T relationship for the propellant tank pressurant, helium. The OMS P-V-T propellant quantity gaging error was determined for four sets of instrumentation configurations and accuracies with the propellant tank operating in the normal constant pressure mode and in the blowdown mode. The instrumentation inaccuracy allowance for propellant leak detection was also computed for these same four sets of instrumentation. These gaging errors and leak detection allowances are presented in tables designed to permit a direct comparison of the effectiveness of the four instrumentation sets. The results show the magnitudes of the improvements in propellant quantity gaging accuracies and propellant leak detection allowances which can be achieved by employing more accurate pressure and temperature instrumentation.

  1. Effects of heat and moisture exchangers on minute ventilation, ventilatory drive, and work of breathing during pressure-support ventilation in acute respiratory failure.

    PubMed

    Pelosi, P; Solca, M; Ravagnan, I; Tubiolo, D; Ferrario, L; Gattinoni, L

    1996-07-01

    To evaluate the effect of two commonly used heat and moisture exchangers on respiratory function and gas exchange in patients with acute respiratory failure during pressure-support ventilation. Prospective, randomized trial. Intensive care unit of a university hospital. Fourteen patients with moderate acute respiratory failure, receiving pressure-support ventilation. Patients were assigned randomly to two treatment groups, in which two different heat and moisture exchangers were used: Hygroster (DAR S.p.A., Mirandola, Italy) with higher deadspace and lower resistance (group 1, n = 7), and Hygrobac-S (DAR S.p.A.) with lower deadspace and higher resistance (group 2, n = 7). Patients were assessed at three pressure-support levels: a) baseline (10.3 +/- 2.4 cm H2O for group 1, 9.3 +/- 1.3 cm H2O for group 2); b) 5 cm H2O above baseline; and c) 5 cm H2O below baseline. Measurements obtained with the heat and moisture exchangers were compared with those values obtained using the standard heated hot water humidifier. At baseline pressure-support ventilation, the insertion of both heat and moisture exchangers induced in all patients a significant increase in the following parameters: minute ventilation (12.4 +/- 3.2 to 15.0 +/- 2.6 L/min for group 1, and 11.8 +/- 3.6 to 14.2 +/- 3.5 L/min for group 2); static intrinsic positive end-expiratory pressure (2.9 +/- 2.0 to 5.1 +/- 3.2 cm H2O for group 1, and 2.9 +/- 1.7 to 5.5 +/- 3.0 cm H2O for group 2); ventilatory drive, expressed as P41 (2.7 +/- 2.0 to 5.2 +/- 4.0 cm H2O for group 1, and 3.3 +/- 2.0 to 5.3 +/- 3.0 cm H2O for group 2); and work of breathing, expressed as either power (8.8 +/- 9.4 to 14.5 +/- 10.3 joule/ min for group 1, and 10.5 +/- 7.4 to 16.6 +/- 11.0 joule/min for group 2) or work per liter of ventilation (0.6 +/- 0.6 to 1.0 +/- 0.7 joule/L for group 1, and 0.8 +/- 0.4 to 1.1 +/- 0.5 joule/L. for group 2). These increases also occurred when pressure-support ventilation was both above and below the baseline

  2. Validation of work pressure and associated factors influencing hospital nurse turnover: a cross-sectional investigation in Shaanxi Province, China.

    PubMed

    Yang, Huiyun; Lv, Jingwen; Zhou, Xi; Liu, Huitong; Mi, Baibing

    2017-02-03

    Nurses' turnover is a major contributor to nursing shortages, strongly influenced by nurses' intentions to leave. Several factors influencing the turnover intention have been well identified in Western countries and large cities in China. However, whether these factors also contribute to nurses' work stress in Midwest China are still unclear. The main purpose of this study was to examine the work pressure and associated factors influencing the nurses' intent to leave. A cross-sectional questionnaire-based survey with multistage sampling was conducted by recruiting 800 employed registered nurses with >1 year of work experience. Chi-square test and multi-factor logistic regression were applied to attain the relative comparisons. Sub-group analysis was conducted to explore the different turnover intention patterns in different age groups. The turnover intention was classified as strong/very-strong (19%), weak (62%), and very-weak (19%). Among the factors influencing the nurses' desire to leave the profession, work pressure was the most prominent. The predominantly associated factors contributing the work stress were age, experience, and workload. However, the scale of income did not affect the intent to leave decision. Pediatrics was identified to be the highest tormented department with a significant (P < 0.05) turnover of nurses. Among different age sub-groups, 30-39 age group nurses in Secondary hospitals demonstrate a stronger intent to leave. Nurses' turnover intentions were associated with stress, age, job duty, and career commitment in Shaanxi Province. The intent to leave is dynamically multifactorial, and effective managements and supportive strategies are needed to reduce the nurses work stress accordingly.

  3. 29 CFR 15.22 - Allowable claims.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... claimant is a civilian employee who is a local inhabitant; or (iii) Any warehouse, office, working area or...) Mobile homes. Claims may be allowed for damage to, or loss of, mobile homes and their contents under the provisions of paragraph (c)(2) of this section. Claims for structural damage to mobile homes, other than that...

  4. Pressure-Sensitive Paints Advance Rotorcraft Design Testing

    NASA Technical Reports Server (NTRS)

    2013-01-01

    The rotors of certain helicopters can spin at speeds as high as 500 revolutions per minute. As the blades slice through the air, they flex, moving into the wind and back out, experiencing pressure changes on the order of thousands of times a second and even higher. All of this makes acquiring a true understanding of rotorcraft aerodynamics a difficult task. A traditional means of acquiring aerodynamic data is to conduct wind tunnel tests using a vehicle model outfitted with pressure taps and other sensors. These sensors add significant costs to wind tunnel testing while only providing measurements at discrete locations on the model's surface. In addition, standard sensor solutions do not work for pulling data from a rotor in motion. "Typical static pressure instrumentation can't handle that," explains Neal Watkins, electronics engineer in Langley Research Center s Advanced Sensing and Optical Measurement Branch. "There are dynamic pressure taps, but your costs go up by a factor of five to ten if you use those. In addition, recovery of the pressure tap readings is accomplished through slip rings, which allow only a limited amount of sensors and can require significant maintenance throughout a typical rotor test." One alternative to sensor-based wind tunnel testing is pressure sensitive paint (PSP). A coating of a specialized paint containing luminescent material is applied to the model. When exposed to an LED or laser light source, the material glows. The glowing material tends to be reactive to oxygen, explains Watkins, which causes the glow to diminish. The more oxygen that is present (or the more air present, since oxygen exists in a fixed proportion in air), the less the painted surface glows. Imaged with a camera, the areas experiencing greater air pressure show up darker than areas of less pressure. "The paint allows for a global pressure map as opposed to specific points," says Watkins. With PSP, each pixel recorded by the camera becomes an optical pressure

  5. Electronic system for monitoring the frequency and pressure of mastication: study and approach for its design.

    PubMed

    Nakamura, Orlando K; Garcia, Daniel O; Villavicencio, Emilio A; Navarro, Luis A; Torres, Miguel A; Huamani, Robinson; Yabar, Leopoldo F

    2010-01-01

    The objective of this work is to study and design a portable non invasive prototype which allows us to supervise the mastication frequency and pressure for specific meals, performing an analysis of sounds and pressures generated by facial muscles when they are chewing. These variables have a direct influence on people nutritious and dietary habits; also, a quickly eating makes people ingest a lot of food instead he needs generating overweight on him. On the other hand, there is no so much study for upheaval of temporal-mandible joints (TMJ) in Peru, keeping as reference that unilateral mastication is one of the principal causes on myofacial pains but, as obesity, there are no studies in Peru about how to prevent these pathologies. In consequence, we propose the development of this prototype which, additional to supervise variables such as mastication frequency and pressure, will allow to the patient an self-correction of his habits.

  6. Dynamic stall characterization using modal analysis of phase-averaged pressure distributions

    NASA Astrophysics Data System (ADS)

    Harms, Tanner; Nikoueeyan, Pourya; Naughton, Jonathan

    2017-11-01

    Dynamic stall characterization by means of surface pressure measurements can simplify the time and cost associated with experimental investigation of unsteady airfoil aerodynamics. A unique test capability has been developed at University of Wyoming over the past few years that allows for time and cost efficient measurement of dynamic stall. A variety of rotorcraft and wind turbine airfoils have been tested under a variety of pitch oscillation conditions resulting in a range of dynamic stall behavior. Formation, development and separation of different flow structures are responsible for the complex aerodynamic loading behavior experienced during dynamic stall. These structures have unique signatures on the pressure distribution over the airfoil. This work investigates the statistical behavior of phase-averaged pressure distribution for different types of dynamic stall by means of modal analysis. The use of different modes to identify specific flow structures is being investigated. The use of these modes for different types of dynamic stall can provide a new approach for understanding and categorizing these flows. This work uses airfoil data acquired under Army contract W911W60160C-0021, DOE Grant DE-SC0001261, and a gift from BP Alternative Energy North America, Inc.

  7. Orthostatic symptoms, blood pressure and working postures of factory and service workers over an observed workday.

    PubMed

    Ngomo, Suzy; Messing, Karen; Perrault, Hélène; Comtois, Alain

    2008-11-01

    North American workers usually stand while working, and prolonged standing is associated with discomfort and cardiovascular problems. Moving may alleviate the problems, but optimum mobility is unknown. The effects of variations in mobility were explored among (1) 34 health care workers whose symptoms of orthostatic intolerance (OI) were recorded after work; (2) 45 factory and laundry workers. Postures were observed over a workday and blood pressure (BP) and heart rate (HR) of both groups were recorded before and after work. Among health care workers, 65% manifested OI symptoms. In a multiple logistic regression, presence of >or= 1 symptom of OI was associated with static postures and being female (p=0.001). More static standing was associated with a larger drop in BP (p=0.04) in both populations. The results suggest that more static standing postures are associated with OI and musculoskeletal symptoms and with a subclinical drop in BP.

  8. Micro X-ray CT Imaging of Sediments under Confining Pressure

    NASA Astrophysics Data System (ADS)

    Schindler, M.; Prasad, M.

    2016-12-01

    We developed a pressure and temperature control system for use inside the micro X-ray CT scanner Xradia 400. We succeeded in building a pressure vessel that can be pressurized to 34.5 MPa (5000 psi) while being transparent to X-rays. The setup can currently be cooled to -5°C and heated to 40°C. We were able to observe grain damage and porosity reduction due to applied confining pressure in clean quartz sand samples and quartz sand and bentonite samples. By comparing micro CT images at atmospheric pressure and 13.8 MPa (2000 psi) confining pressure, we observed compaction of the samples resulting in grain damage and fracturing of sediment grains (Figure 1). When the confining pressure was decreased some grains experienced further fracturing. The grain damage appears irreversible. Further fracturing of grains in pre-compacted sediment was observed upon repeated confining pressure cycling. We are currently working on feed-throughs for fluid lines and electric wiring to use ultrasonic transducers and pressure control in combination. Further we plan to include pore pressure in addition to confining pressure into the system. The pressure control system in combination with ultrasonic transducers will allow us to visually observe pore scale changes in rock samples while simultaneously identifying their influence on ultrasonic velocities. Such pore-scale changes are usually not taken into account by rock physics models and could help to identify why laboratory data diverges from theoretical models. Further, it is possible to compute compressibility from mCT images at different stress states by image correlation

  9. Water cooled static pressure probe

    NASA Technical Reports Server (NTRS)

    Lagen, Nicholas T. (Inventor); Eves, John W. (Inventor); Reece, Garland D. (Inventor); Geissinger, Steve L. (Inventor)

    1991-01-01

    An improved static pressure probe containing a water cooling mechanism is disclosed. This probe has a hollow interior containing a central coolant tube and multiple individual pressure measurement tubes connected to holes placed on the exterior. Coolant from the central tube symmetrically immerses the interior of the probe, allowing it to sustain high temperature (in the region of 2500 F) supersonic jet flow indefinitely, while still recording accurate pressure data. The coolant exits the probe body by way of a reservoir attached to the aft of the probe. The pressure measurement tubes are joined to a single, larger manifold in the reservoir. This manifold is attached to a pressure transducer that records the average static pressure.

  10. Intraoperative Endotracheal Cuff Pressure Study: How Education and Availability of Manometers Help Guide Safer Pressures.

    PubMed

    Stevens, Gregory J; Warfel, Joel W; Aden, James K; Blackwell, Scott D

    2018-02-13

    Endotracheal intubation is a medical procedure that is often indicated in both the perioperative and critical care environments. Cuffed endotracheal tubes (ETT) allow for safer and more efficient delivery of positive pressure ventilation, as well as create a barrier to reduce the risk of micro-aspiration and anesthetic pollution in the operating room environment. Over-inflation of the endotracheal cuff can lead to serious and harmful sequelae. This study aimed to assess if departmental education paired with ready access to a manometer to assess cuff pressure would result in an improvement in the proportion of ETT cuff pressures in the goal range. A quality improvement study was conducted at the San Antonio Military Medical Center (SAMMC; Department of Defense hospital in San Antonio, TX). The initiative was divided into three key periods: pre-implementation, implementation, and post-implementation. During the pre-implementation period, ETT cuff pressures were obtained to assess the baseline state of ETT cuff pressures for patients in the operating room; the proportion of in-range (20-30 cmH2O) pressures was calculated. During the implementation phase, operating rooms were equipped with manometers and anesthesia departmental education was performed regarding the use of the manometers. Three months later, post-implementation cuff pressures were measured in the OR, and the proportion of in-range pressures was again calculated. The pre-implementation data showed an average cuff pressure of 48.92 cmH2O and a median of 38.5 cmH2O. Of the 100 pre-implementation pressures, 20 were in the goal range. Post-implementation data had an average cuff pressure of 41.96 cmH2O and a median of 30 cmH2O. A chi-squared test of pressures in the safe range from the pre-implementation versus post-implementation values yielded a highly significant p-value of 0.0003. The data from this study clearly demonstrated a statistically significant improvement in the proportion of in-range cuff

  11. 42 CFR 61.9 - Payments: Stipends; dependency allowances; travel allowances.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 42 Public Health 1 2014-10-01 2014-10-01 false Payments: Stipends; dependency allowances; travel... FELLOWSHIPS, INTERNSHIPS, TRAINING FELLOWSHIPS Regular Fellowships § 61.9 Payments: Stipends; dependency allowances; travel allowances. Payments for stipends, dependency allowances, and the travel allowances...

  12. 42 CFR 61.9 - Payments: Stipends; dependency allowances; travel allowances.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 42 Public Health 1 2012-10-01 2012-10-01 false Payments: Stipends; dependency allowances; travel... FELLOWSHIPS, INTERNSHIPS, TRAINING FELLOWSHIPS Regular Fellowships § 61.9 Payments: Stipends; dependency allowances; travel allowances. Payments for stipends, dependency allowances, and the travel allowances...

  13. 42 CFR 61.9 - Payments: Stipends; dependency allowances; travel allowances.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 1 2011-10-01 2011-10-01 false Payments: Stipends; dependency allowances; travel... FELLOWSHIPS, INTERNSHIPS, TRAINING FELLOWSHIPS Regular Fellowships § 61.9 Payments: Stipends; dependency allowances; travel allowances. Payments for stipends, dependency allowances, and the travel allowances...

  14. 42 CFR 61.9 - Payments: Stipends; dependency allowances; travel allowances.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 42 Public Health 1 2013-10-01 2013-10-01 false Payments: Stipends; dependency allowances; travel... FELLOWSHIPS, INTERNSHIPS, TRAINING FELLOWSHIPS Regular Fellowships § 61.9 Payments: Stipends; dependency allowances; travel allowances. Payments for stipends, dependency allowances, and the travel allowances...

  15. 42 CFR 61.9 - Payments: Stipends; dependency allowances; travel allowances.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Payments: Stipends; dependency allowances; travel... FELLOWSHIPS, INTERNSHIPS, TRAINING FELLOWSHIPS Regular Fellowships § 61.9 Payments: Stipends; dependency allowances; travel allowances. Payments for stipends, dependency allowances, and the travel allowances...

  16. Work of breathing during lung-protective ventilation in patients with acute lung injury and acute respiratory distress syndrome: a comparison between volume and pressure-regulated breathing modes.

    PubMed

    Kallet, Richard H; Campbell, Andre R; Dicker, Rochelle A; Katz, Jeffrey A; Mackersie, Robert C

    2005-12-01

    Pressure-control ventilation (PCV) and pressure-regulated volume-control (PRVC) ventilation are used during lung-protective ventilation because the high, variable, peak inspiratory flow rate (V (I)) may reduce patient work of breathing (WOB) more than the fixed V (I) of volume-control ventilation (VCV). Patient-triggered breaths during PCV and PRVC may result in excessive tidal volume (V(T)) delivery unless the inspiratory pressure is reduced, which in turn may decrease the peak V (I). We tested whether PCV and PRVC reduce WOB better than VCV with a high, fixed peak V (I) (75 L/min) while also maintaining a low V(T) target. Fourteen nonconsecutive patients with acute lung injury or acute respiratory distress syndrome were studied prospectively, using a random presentation of ventilator modes in a crossover, repeated-measures design. A target V(T) of 6.4 + 0.5 mL/kg was set during VCV and PRVC. During PCV the inspiratory pressure was set to achieve the same V(T). WOB and other variables were measured with a pulmonary mechanics monitor (Bicore CP-100). There was a nonsignificant trend toward higher WOB (in J/L) during PCV (1.27 + 0.58 J/L) and PRVC (1.35 + 0.60 J/L), compared to VCV (1.09 + 0.59 J/L). While mean V(T) was not statistically different between modes, in 40% of patients, V(T) markedly exceeded the lung-protective ventilation target during PRVC and PCV. During lung-protective ventilation, PCV and PRVC offer no advantage in reducing WOB, compared to VCV with a high flow rate, and in some patients did not allow control of V(T) to be as precise.

  17. High Blood Pressure and Women

    MedlinePlus

    ... fact sheet on high blood pressure . Watch interactive animations of how blood pressure works . See all the ... Matter • Find Tools & Resources HBP Resources Risk Calculator Animation Library Track Your Blood Pressure: Print (PDF) | Online ...

  18. Efficient use of mobile devices for quantification of pressure injury images.

    PubMed

    Garcia-Zapirain, Begonya; Sierra-Sosa, Daniel; Ortiz, David; Isaza-Monsalve, Mariano; Elmaghraby, Adel

    2018-01-01

    Pressure Injuries are chronic wounds that are formed due to the constriction of the soft tissues against bone prominences. In order to assess these injuries, the medical personnel carry out the evaluation and diagnosis using visual methods and manual measurements, which can be inaccurate and may generate discomfort in the patients. By using segmentation techniques, the Pressure Injuries can be extracted from an image and accurately parameterized, leading to a correct diagnosis. In general, these techniques are based on the solution of differential equations and the involved numerical methods are demanding in terms of computational resources. In previous work, we proposed a technique developed using toroidal parametric equations for image decomposition and segmentation without solving differential equations. In this paper, we present the development of a mobile application useful for the non-contact assessment of Pressure Injuries based on the toroidal decomposition from images. The usage of this technique allows us to achieve an accurate segmentation almost 8 times faster than Active Contours without Edges (ACWE) and Dynamic Contours methods. We describe the techniques and the implementation for Android devices using Python and Kivy. This application allows for the segmentation and parameterization of injuries, obtain relevant information for the diagnosis and tracking the evolution of patient's injuries.

  19. 14 CFR 25.365 - Pressurized compartment loads.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... Pressurized compartment loads. For airplanes with one or more pressurized compartments the following apply: (a... differential loads from zero up to the maximum relief valve setting. (b) The external pressure distribution in... zero up to the maximum allowed during landing. (d) The airplane structure must be designed to be able...

  20. Pressure-Application Device for Testing Pressure Sensors

    NASA Technical Reports Server (NTRS)

    2002-01-01

    A portable pressure-application device has been designed and built for use in testing and calibrating piezoelectric pressure transducers in the field. The device generates pressure pulses of known amplitude. A pressure pulse (in contradistinction to a steady pressure) is needed because in the presence of a steady pressure, the electrical output of a piezoelectric pressure transducer decays rapidly with time. The device includes a stainless- steel compressed-air-storage cylinder of 500 cu cm volume. A manual hand pump with check valves and a pressure gauge are located at one end of the cylinder. A three-way solenoid valve that controls the release of pressurized air is located at the other end of the cylinder. Power for the device is provided by a 3.7-V cordless-telephone battery. The valve is controlled by means of a pushbutton switch, which activates a 5 V to +/-15 V DC-to-DC converter that powers the solenoid. The outlet of the solenoid valve is connected to the pressure transducer to be tested. Before the solenoid is energized, the transducer to be tested is at atmospheric pressure. When the solenoid is actuated by the push button, pressurized air from inside the cylinder is applied to the transducer. Once the pushbutton is released, the cylinder pressure is removed from the transducer and the pressurized air applied to the transducer is vented, bringing the transducer back to atmospheric pressure. Before this device was used for actual calibration, its accuracy was checked with a NIST (National Institute of Standards and Technology) traceable calibrator and commercially calibrated pressure transducers. This work was done by Wanda Solano of Stennis Space Center and Greg Richardson of Lockheed Martin Corp.

  1. High Blood Pressure and Kidney Disease

    MedlinePlus

    ... Your Kidneys & How They Work High Blood Pressure & Kidney Disease What is high blood pressure? Blood pressure ... have their blood pressure checked. What are the kidneys and what do they do? The kidneys are ...

  2. (Ultra) High Pressure Homogenization for Continuous High Pressure Sterilization of Pumpable Foods – A Review

    PubMed Central

    Georget, Erika; Miller, Brittany; Callanan, Michael; Heinz, Volker; Mathys, Alexander

    2014-01-01

    Bacterial spores have a strong resistance to both chemical and physical hurdles and create a risk for the food industry, which has been tackled by applying high thermal intensity treatments to sterilize food. These strong thermal treatments lead to a reduction of the organoleptic and nutritional properties of food and alternatives are actively searched for. Innovative hurdles offer an alternative to inactivate bacterial spores. In particular, recent technological developments have enabled a new generation of high pressure homogenizer working at pressures up to 400 MPa and thus, opening new opportunities for high pressure sterilization of foods. In this short review, we summarize the work conducted on (ultra) high pressure homogenization (U)HPH to inactivate endospores in model and food systems. Specific attention is given to process parameters (pressure, inlet, and valve temperatures). This review gathers the current state of the art and underlines the potential of UHPH sterilization of pumpable foods while highlighting the needs for future work. PMID:25988118

  3. Apparatus and method for pressure testing closure disks

    DOEpatents

    Merten, Jr., Charles W.

    1992-01-21

    A method and device for testing the burst pressure of closure disks which provides high pressure to both sides of a disk and rapidly releases pressure from one side thereof causing a high rate of change of pressure. A hollow notched plug allows the rapid release of pressure upon rupturing. A tensile load is transmitted by a piston in combination with fluid pressure to the hollow notched plug.

  4. Diurnal blood pressure changes.

    PubMed

    Asayama, Kei; Satoh, Michihiro; Kikuya, Masahiro

    2018-05-23

    The definition of diurnal blood pressure changes varies widely, which can be confusing. Short-term blood pressure variability during a 24-h period and the dipping status of diurnal blood pressure can be captured by ambulatory blood pressure monitoring, and these metrics are reported to have prognostic significance for cardiovascular complications. Morning blood pressure surge also indicates this risk, but its effect may be limited to populations with specific conditions. Meanwhile, the combined use of conventional office blood pressure and out-of-office blood pressure allows us to identify people with white-coat and masked hypertension. Current home devices can measure nocturnal blood pressure during sleep more conveniently than ambulatory monitoring; however, we should pay attention to blood pressure measurement conditions regardless of whether they are in a home, ambulatory, or office setting. The relatively poor reproducibility of diurnal blood pressure changes, including the nocturnal fall of blood pressure, is another underestimated issue to be addressed. Although information on diurnal blood pressure changes is expected to be used more effectively in the future, we should also keep in mind that blood pressure levels have remained central to the primary and secondary prevention of blood pressure-related cardiovascular diseases in clinical practice.

  5. Determining Atmospheric Pressure Using a Water Barometer

    ERIC Educational Resources Information Center

    Lohrengel, C. Frederick, II; Larson, Paul R.

    2012-01-01

    The atmosphere is an envelope of compressible gases that surrounds Earth. Because of its compressibility and nonuniform heating by the Sun, it is in constant motion. The atmosphere exerts pressure on Earth's surface, but that pressure is in constant flux. This experiment allows students to directly measure atmospheric pressure by measuring the…

  6. 34 CFR 673.7 - Administrative cost allowance.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... EDUCATION, DEPARTMENT OF EDUCATION GENERAL PROVISIONS FOR THE FEDERAL PERKINS LOAN PROGRAM, FEDERAL WORK... Federal Perkins Loan, FWS, and FSEOG Programs § 673.7 Administrative cost allowance. (a) An institution participating in the Federal Perkins Loan, FWS, or FSEOG programs is entitled to an administrative cost...

  7. 34 CFR 673.7 - Administrative cost allowance.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... EDUCATION, DEPARTMENT OF EDUCATION GENERAL PROVISIONS FOR THE FEDERAL PERKINS LOAN PROGRAM, FEDERAL WORK... Federal Perkins Loan, FWS, and FSEOG Programs § 673.7 Administrative cost allowance. (a) An institution participating in the Federal Perkins Loan, FWS, or FSEOG programs is entitled to an administrative cost...

  8. Flow and pressure characteristics within a screw compressor

    NASA Astrophysics Data System (ADS)

    Guerrato, D.; Nouri, J. M.; Stosic, N.; Arcoumanis, C.

    2007-10-01

    The angle-resolved mean and turbulence characteristics of the axial air flow inside a screw compressor with both male and female rotors have been measured, using a laser Doppler velocimeter (LDV) with high spatial and temporal resolution at different radial and axial locations for speeds of 800-1600 rpm, discharge pressures of 1-1.6 bar and discharge temperatures of 33-90°C. The velocity measurements were performed through a special transparent window fixed near the discharge port. The results confirmed the ability of the LDV technique to characterise the flow inside the compressor working chamber; an angular resolution of 1.5° was able to fully describe the velocity field within the machine. The flow variation between the different working chambers was established as well as the spatial variation of the axial mean velocity and turbulence velocity fluctuation within the working chamber. The effect of discharge port opening on the axial mean and RMS velocities was found to be significant near the leading edge of the rotors causing an increase in the mean and RMS velocities of the order of 4.2Vp in mean (where Vp is the axial pitched velocity) for male rotor and 5.4Vp for, female rotor and this effect is less pronounced on the flow near the root of the rotor. Moreover, to obtain a better understanding of the flow motion, a high sampling rate pressure transducer was used to provide the internal angular static pressure variation. These measurements are used to validate the in-house CFD model of the fluid flow within twin screw compressors which, in turn, allows reliable optimisation of various compressor designs.

  9. Prediction of Sublimation Pressures of Low Volatility Solids

    NASA Astrophysics Data System (ADS)

    Drake, Bruce Douglas

    Sublimation pressures are required for solid-vapor phase equilibrium models in design of processes such as supercritical fluid extraction, sublimation purification and vapor epitaxy. The objective of this work is to identify and compare alternative methods for predicting sublimation pressures. A bibliography of recent sublimation data is included. Corresponding states methods based on the triple point (rather than critical point) are examined. A modified Trouton's rule is the preferred method for estimating triple point pressure in the absence of any sublimation data. Only boiling and melting temperatures are required. Typical error in log_{10} P _{rm triple} is 0.3. For lower temperature estimates, the slope of the sublimation curve is predicted by a correlation based on molar volume. Typical error is 10% of slope. Molecular dynamics methods for surface modeling are tested as estimators of vapor pressure. The time constants of the vapor and solid phases are too different to allow the vapor to come to thermal equilibrium with the solid. The method shows no advantages in prediction of sublimation pressure but provides insight into appropriate models and experimental methods for sublimation. Density-dependent augmented van der Waals equations of state based on hard-sphere distribution functions are examined. The perturbation term is almost linear and is well fit by a simple quadratic. Use of the equation provides reasonable fitting of sublimation pressures from one data point. Order-of-magnitude estimation is possible from melting temperature and solid molar volume. The inverse -12 fluid is used to develop an additional equation of state. Sublimation pressure results, including quality of pressure predictions, are similar to the hard-sphere results. Three-body (Axilrod -Teller) interactions are used to improve results.

  10. A dc non-thermal atmospheric-pressure plasma microjet

    NASA Astrophysics Data System (ADS)

    Zhu, WeiDong; Lopez, Jose L.

    2012-06-01

    A direct current (dc), non-thermal, atmospheric-pressure plasma microjet is generated with helium/oxygen gas mixture as working gas. The electrical property is characterized as a function of the oxygen concentration and show distinctive regions of operation. Side-on images of the jet were taken to analyze the mode of operation as well as the jet length. A self-pulsed mode is observed before the transition of the discharge to normal glow mode. Optical emission spectroscopy is employed from both end-on and side-on along the jet to analyze the reactive species generated in the plasma. Line emissions from atomic oxygen (at 777.4 nm) and helium (at 706.5 nm) were studied with respect to the oxygen volume percentage in the working gas, flow rate and discharge current. Optical emission intensities of Cu and OH are found to depend heavily on the oxygen concentration in the working gas. Ozone concentration measured in a semi-confined zone in front of the plasma jet is found to be from tens to ˜120 ppm. The results presented here demonstrate potential pathways for the adjustment and tuning of various plasma parameters such as reactive species selectivity and quantities or even ultraviolet emission intensities manipulation in an atmospheric-pressure non-thermal plasma source. The possibilities of fine tuning these plasma species allows for enhanced applications in health and medical related areas.

  11. Experiments with a pressure-driven Stirling refrigerator with flexible chambers

    NASA Astrophysics Data System (ADS)

    McFarlane, Patrick; Suire, Jonathan; Sen, Mihir; Semperlotti, Fabio

    2014-06-01

    We report on the design and experimental testing of a Stirling refrigerator that uses air as the working fluid, and where the conventional piston-cylinder assemblies are replaced by pressure-driven flexible chambers. The two chambers are periodically compressed by pneumatic actuators resulting in airflow through the regenerator and in a net temperature difference between the chambers. An experimental setup is used to investigate the performance of the refrigerator under different operating conditions with particular attention to actuation frequencies, driving pressure differences, and phase angles between the two inputs. The time constant of the temperature difference between the two chambers is determined, and the temperature difference is measured as a function of the system parameters. The results of several tests conducted under different operating conditions show that the refrigerating effect is very robust and allows good performance even for modulated inputs. The frequency response is radically different from that of a traditional motion-driven device. This work suggests that mechanical to thermal energy conversion devices based on this principle can be successfully powered by human motion.

  12. Novel design for transparent high-pressure fuel injector nozzles.

    PubMed

    Falgout, Z; Linne, M

    2016-08-01

    The efficiency and emissions of internal combustion (IC) engines are closely tied to the formation of the combustible air-fuel mixture. Direct-injection engines have become more common due to their increased practical flexibility and efficiency, and sprays dominate mixture formation in these engines. Spray formation, or rather the transition from a cylindrical liquid jet to a field of isolated droplets, is not completely understood. However, it is known that nozzle orifice flow and cavitation have an important effect on the formation of fuel injector sprays, even if the exact details of this effect remain unknown. A number of studies in recent years have used injectors with optically transparent nozzles (OTN) to allow observation of the nozzle orifice flow. Our goal in this work is to design various OTN concepts that mimic the flow inside commercial injector nozzles, at realistic fuel pressures, and yet still allow access to the very near nozzle region of the spray so that interior flow structure can be correlated with primary breakup dynamics. This goal has not been achieved until now because interior structures can be very complex, and the most appropriate optical materials are brittle and easily fractured by realistic fuel pressures. An OTN design that achieves realistic injection pressures and grants visual access to the interior flow and spray formation will be explained in detail. The design uses an acrylic nozzle, which is ideal for imaging the interior flow. This nozzle is supported from the outside with sapphire clamps, which reduces tensile stresses in the nozzle and increases the nozzle's injection pressure capacity. An ensemble of nozzles were mechanically tested to prove this design concept.

  13. Active workstation allows office workers to work efficiently while sitting and exercising moderately.

    PubMed

    Koren, Katja; Pišot, Rado; Šimunič, Boštjan

    2016-05-01

    To determine the effects of a moderate-intensity active workstation on time and error during simulated office work. The aim of the study was to analyse simultaneous work and exercise for non-sedentary office workers. We monitored oxygen uptake, heart rate, sweating stains area, self-perceived effort, typing test time with typing error count and cognitive performance during 30 min of exercise with no cycling or cycling at 40 and 80 W. Compared baseline, we found increased physiological responses at 40 and 80 W, which corresponds to moderate physical activity (PA). Typing time significantly increased by 7.3% (p = 0.002) in C40W and also by 8.9% (p = 0.011) in C80W. Typing error count and cognitive performance were unchanged. Although moderate intensity exercise performed on cycling workstation during simulated office tasks increases working task execution time with, it has moderate effect size; however, it does not increase the error rate. Participants confirmed that such a working design is suitable for achieving the minimum standards for daily PA during work hours. Copyright © 2015 Elsevier Ltd and The Ergonomics Society. All rights reserved.

  14. A Graphene-Based Resistive Pressure Sensor with Record-High Sensitivity in a Wide Pressure Range

    PubMed Central

    Tian, He; Shu, Yi; Wang, Xue-Feng; Mohammad, Mohammad Ali; Bie, Zhi; Xie, Qian-Yi; Li, Cheng; Mi, Wen-Tian; Yang, Yi; Ren, Tian-Ling

    2015-01-01

    Pressure sensors are a key component in electronic skin (e-skin) sensing systems. Most reported resistive pressure sensors have a high sensitivity at low pressures (<5 kPa) to enable ultra-sensitive detection. However, the sensitivity drops significantly at high pressures (>5 kPa), which is inadequate for practical applications. For example, actions like a gentle touch and object manipulation have pressures below 10 kPa, and 10–100 kPa, respectively. Maintaining a high sensitivity in a wide pressure range is in great demand. Here, a flexible, wide range and ultra-sensitive resistive pressure sensor with a foam-like structure based on laser-scribed graphene (LSG) is demonstrated. Benefitting from the large spacing between graphene layers and the unique v-shaped microstructure of the LSG, the sensitivity of the pressure sensor is as high as 0.96 kPa−1 in a wide pressure range (0 ~ 50 kPa). Considering both sensitivity and pressure sensing range, the pressure sensor developed in this work is the best among all reported pressure sensors to date. A model of the LSG pressure sensor is also established, which agrees well with the experimental results. This work indicates that laser scribed flexible graphene pressure sensors could be widely used for artificial e-skin, medical-sensing, bio-sensing and many other areas. PMID:25721159

  15. Improving liquid chromatography-mass spectrometry sensitivity using a subambient pressure ionization with nanoelectrospray (SPIN) interface

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tang, Keqi; Page, Jason S.; Marginean, Ioan

    2011-04-22

    In this work the Subambient Pressure Ionization with Nanoelectrospray (SPIN) ion source and interface which operates at ~15-30 Torr is demonstrated to be compatible with gradient reversed-phase liquid chromatography-MS applications, exemplified here with the analysis of complex samples (a protein tryptic digest and a whole cell lysate). A low liquid chromatographic flow rate (100-400 nL/min) allowed stable electrospray to be established while avoiding electrical breakdown. Efforts to increase the operating pressure of the SPIN source relative to previously reported designs prevented solvent freezing and enhanced charged cluster/droplet desolvation. A 5-12-fold improvement in sensitivity relative to a conventional atmospheric pressure nanoelectrospraymore » ionization (ESI) source was obtained for detected peptides.« less

  16. Polarized pressure dependence of the anisotropic dielectric functions of highly oriented poly(p-phenylene vinylene)

    NASA Astrophysics Data System (ADS)

    Morandi, V.; Galli, M.; Marabelli, F.; Comoretto, D.

    2010-04-01

    In this work, we combined an experimental technique and a detailed data analysis to investigate the influence of an applied pressure on the anisotropic dielectric functions of highly oriented poly(p-phenylene vinylene) (PPV). The dielectric constants were derived from polarized reflectance spectra recorded through a diamond anvil cell up to 50 kbar. The presence of the diamond anvils strongly affects measured spectra requiring the development in an optical model able to take all spurious effects into account. A parametric procedure was then applied to derive the complex dielectric constants for both polarizations as a function of pressure. A detailed analysis of their pressure dependence allows addressing the role of intermolecular interactions and electron-phonon coupling in highly oriented PPV.

  17. Flexible work in call centres: Working hours, work-life conflict & health.

    PubMed

    Bohle, Philip; Willaby, Harold; Quinlan, Michael; McNamara, Maria

    2011-01-01

    Call-centre workers encounter major psychosocial pressures, including high work intensity and undesirable working hours. Little is known, however, about whether these pressures vary with employment status and how they affect work-life conflict and health. Questionnaire data were collected from 179 telephone operators in Sydney, Australia, of whom 124 (69.3%) were female and 54 (30.2%) were male. Ninety-three (52%) were permanent full-time workers, 37 (20.7%) were permanent part-time, and 49 (27.4%) were casual employees. Hypothesised structural relationships between employment status, working hours and work organisation, work-life conflict and health were tested using partial least squares modelling in PLS (Chin, 1998). The final model demonstrated satisfactory fit. It supported important elements of the hypothesised structure, although four of the proposed paths failed to reach significance and the fit was enhanced by adding a path. The final model indicated that casual workers reported more variable working hours which were relatively weakly associated with greater dissatisfaction with hours. The interaction of schedule control and variability of hours also predicted dissatisfaction with hours. Conversely, permanent workers reported greater work intensity, which was associated with both lower work schedule control and greater work-life conflict. Greater work-life conflict was associated with more fatigue and psychological symptoms. Labour market factors and the undesirability of longer hours in a stressful, high-intensity work environment appear to have contributed to the results. Copyright © 2010 Elsevier Ltd and The Ergonomics Society. All rights reserved.

  18. External pressure measurement system

    NASA Astrophysics Data System (ADS)

    Chandler, Jon K.; Fowler, Don P.

    Hydraulic systems comprise an important part of jet aircraft and their pressure needs must be checked constantly. Tests of the prototype external pressure measurement system show that it is possible to accurately convert the small expansion of tubing with pressure into a direct pressure reading without inserting a pressure gage into the piping system. The tool described in the paper is a clamp-on displacement transducer that can read pressure directly in PSI from 0 to 5000. Some limitations concerning temperature and accuracy should be remedied by additional design work. The system promises to streamline troubleshooting of all types of piping systems.

  19. High pressure working mode of hollow cathode arc discharges

    NASA Technical Reports Server (NTRS)

    Minoo, H.; Popovici, C.

    1985-01-01

    The behavior of high pressure cathotrons is discussed. Methods of preheating either the gas or the cathode itself are detailed together with various geometries for the hollow cathode. Three special configurations were tested, and the results are analyzed.

  20. Oscillatory lower body negative pressure impairs working memory task-related functional hyperemia in healthy volunteers.

    PubMed

    Merchant, Sana; Medow, Marvin S; Visintainer, Paul; Terilli, Courtney; Stewart, Julian M

    2017-04-01

    Neurovascular coupling (NVC) describes the link between an increase in task-related neural activity and increased cerebral blood flow denoted "functional hyperemia." We previously showed induced cerebral blood flow oscillations suppressed functional hyperemia; conversely functional hyperemia also suppressed cerebral blood flow oscillations. We used lower body negative pressure (OLBNP) oscillations to force oscillations in middle cerebral artery cerebral blood flow velocity (CBFv). Here, we used N-back testing, an intellectual memory challenge as a neural activation task, to test the hypothesis that OLBNP-induced oscillatory cerebral blood flow can reduce functional hyperemia and NVC produced by a working memory task and can interfere with working memory. We used OLBNP (-30 mmHg) at 0.03, 0.05, and 0.10 Hz and measured spectral power of CBFv at all frequencies. Neither OLBNP nor N-back, alone or combined, affected hemodynamic parameters. 2-Back power and OLBNP individually were compared with 2-back power during OLBNP. 2-Back alone produced a narrow band increase in oscillatory arterial pressure (OAP) and oscillatory cerebral blood flow power centered at 0.0083 Hz. Functional hyperemia in response to 2-back was reduced to near baseline and 2-back memory performance was decreased by 0.03-, 0.05-, and 0.10-Hz OLBNP. OLBNP alone produced increased oscillatory power at frequencies of oscillation not suppressed by added 2-back. However, 2-back preceding OLBNP suppressed OLBNP power. OLBNP-driven oscillatory CBFv blunts NVC and memory performance, while memory task reciprocally interfered with forced CBFv oscillations. This shows that induced cerebral blood flow oscillations suppress functional hyperemia and functional hyperemia suppresses cerebral blood flow oscillations. NEW & NOTEWORTHY We show that induced cerebral blood flow oscillations suppress functional hyperemia produced by a working memory task as well as memory task performance. We conclude that oscillatory

  1. Soft, Transparent, Electronic Skin for Distributed and Multiple Pressure Sensing

    PubMed Central

    Levi, Alessandro; Piovanelli, Matteo; Furlan, Silvano; Mazzolai, Barbara; Beccai, Lucia

    2013-01-01

    In this paper we present a new optical, flexible pressure sensor that can be applied as smart skin to a robot or to consumer electronic devices. We describe a mechano-optical transduction principle that can allow the encoding of information related to an externally applied mechanical stimulus, e.g., contact, pressure and shape of contact. The physical embodiment that we present in this work is an electronic skin consisting of eight infrared emitters and eight photo-detectors coupled together and embedded in a planar PDMS waveguide of 5.5 cm diameter. When a contact occurs on the sensing area, the optical signals reaching the peripheral detectors experience a loss because of the Frustrated Total Internal Reflection and deformation of the material. The light signal is converted to electrical signal through an electronic system and a reconstruction algorithm running on a computer reconstructs the pressure map. Pilot experiments are performed to validate the tactile sensing principle by applying external pressures up to 160 kPa. Moreover, the capabilities of the electronic skin to detect contact pressure at multiple subsequent positions, as well as its function on curved surfaces, are validated. A weight sensitivity of 0.193 gr−1 was recorded, thus making the electronic skin suitable to detect pressures in the order of few grams. PMID:23686140

  2. A Comparison between Oceanographic Parameters and Seafloor Pressures; Measured, Theoretical and Modelled, and Terrestrial Seismic Data

    NASA Astrophysics Data System (ADS)

    Donne, Sarah; Bean, Christopher; Craig, David; Dias, Frederic; Christodoulides, Paul

    2016-04-01

    Microseisms are continuous seismic vibrations which propagate mainly as surface Rayleigh and Love waves. They are generated by the Earth's oceans and there are two main types; primary and secondary microseisms. Primary microseisms are generated through the interaction of travelling surface gravity ocean waves with the seafloor in shallow waters relative to the wavelength of the ocean wave. Secondary microseisms, on the other hand are generated when two opposing wave trains interact and a non-linear second order effect produces a pressure fluctuation which is depth independent. The conditions necessary to produce secondary microseisms are presented in Longuet-Higgins (1950) through the interaction of two travelling waves with the same wave period and which interact at an angle of 180 degrees. Equivalent surface pressure density (p2l) is modelled using the numerical ocean wave model Wavewatch III and this term is considered as the microseism source term. This work presents an investigation of the theoretical second order pressures generated through the interaction of travelling waves with varying wave amplitude, period and angle of incidence. Predicted seafloor pressures calculated off the Southwest coast of Ireland are compared with terrestrially recorded microseism records, measured seafloor pressures and oceanographic parameters. The work presented in this study suggests that a broad set of sea states can generate second order seafloor pressures that are consistent with seafloor pressure measurements. Local seismic arrays throughout Ireland allow us to investigate the temporal covariance of these seafloor pressures with microseism source locations.

  3. Nano-viscosity of supercooled liquid measured by fluorescence correlation spectroscopy: Pressure and temperature dependence and the density scaling

    NASA Astrophysics Data System (ADS)

    Meier, G.; Gapinski, J.; Ratajczyk, M.; Lettinga, M. P.; Hirtz, K.; Banachowicz, E.; Patkowski, A.

    2018-03-01

    The Stokes-Einstein relation allows us to calculate apparent viscosity experienced by tracers in complex media on the basis of measured self-diffusion coefficients. Such defined nano-viscosity values can be obtained through single particle techniques, like fluorescence correlation spectroscopy (FCS) and particle tracking (PT). In order to perform such measurements, as functions of pressure and temperature, a new sample cell was designed and is described in this work. We show that this cell in combination with a long working distance objective of the confocal microscope can be used for successful FCS, PT, and confocal imaging experiments in broad pressure (0.1-100 MPa) and temperature ranges. The temperature and pressure dependent nano-viscosity of a van der Waals liquid obtained from the translational diffusion coefficient measured in this cell by means of FCS obeys the same scaling as the rotational relaxation and macro-viscosity of the system.

  4. 21 CFR 868.2700 - Pressure regulator.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... purposes and that is used to convert a medical gas pressure from a high variable pressure to a lower, more constant working pressure. This device includes mechanical oxygen regulators. (b) Classification. Class I...

  5. A whole-body mathematical model for intracranial pressure dynamics.

    PubMed

    Lakin, William D; Stevens, Scott A; Tranmer, Bruce I; Penar, Paul L

    2003-04-01

    Most attempts to study intracranial pressure using lumped-parameter models have adopted the classical "Kellie-Monro Doctrine," which considers the intracranial space to be a closed system that is confined within the nearly-rigid skull, conserves mass, and has equal inflow and outflow. The present work revokes this Doctrine and develops a mathematical model for the dynamics of intracranial pressures, volumes, and flows that embeds the intracranial system in extensive whole-body physiology. The new model consistently introduces compartments representing the tissues and vasculature of the extradural portions of the body, including both the thoracic region and the lower extremities. In addition to vascular connections, a spinal-subarachnoid cerebrospinal fluid (CSF) compartment bridges intracranial and extracranial physiology allowing explict buffering of intracranial pressure fluctuations by the spinal theca. The model contains cerebrovascular autoregulation, regulation of systemic vascular pressures by the sympathetic nervous system, regulation of CSF production in the choroid plexus, a lymphatic system, colloid osmotic pressure effects, and realistic descriptions of cardiac output. To validate the model in situations involving normal physiology, the model's response to a realistic pulsatile cardiac output is examined. A well-known experimentally-derived intracranial pressure-volume relationship is recovered by using the model to simulate CSF infusion tests, and the effect on cerebral blood flow of a change in body position is also examined. Cardiac arrest and hemorrhagic shock are simulated to demonstrate the predictive capabilities of the model in pathological conditions.

  6. 42 CFR 61.8 - Benefits: Stipends; dependency allowances; travel allowances; vacation.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 42 Public Health 1 2014-10-01 2014-10-01 false Benefits: Stipends; dependency allowances; travel...; dependency allowances; travel allowances; vacation. Individuals awarded regular fellowships shall be entitled...) Stipend. (b) Dependency allowances. (c) When authorized in advance, separate allowances for travel. Such...

  7. 42 CFR 61.8 - Benefits: Stipends; dependency allowances; travel allowances; vacation.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 1 2011-10-01 2011-10-01 false Benefits: Stipends; dependency allowances; travel...; dependency allowances; travel allowances; vacation. Individuals awarded regular fellowships shall be entitled...) Stipend. (b) Dependency allowances. (c) When authorized in advance, separate allowances for travel. Such...

  8. 42 CFR 61.8 - Benefits: Stipends; dependency allowances; travel allowances; vacation.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Benefits: Stipends; dependency allowances; travel...; dependency allowances; travel allowances; vacation. Individuals awarded regular fellowships shall be entitled...) Stipend. (b) Dependency allowances. (c) When authorized in advance, separate allowances for travel. Such...

  9. 42 CFR 61.8 - Benefits: Stipends; dependency allowances; travel allowances; vacation.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 42 Public Health 1 2012-10-01 2012-10-01 false Benefits: Stipends; dependency allowances; travel...; dependency allowances; travel allowances; vacation. Individuals awarded regular fellowships shall be entitled...) Stipend. (b) Dependency allowances. (c) When authorized in advance, separate allowances for travel. Such...

  10. 42 CFR 61.8 - Benefits: Stipends; dependency allowances; travel allowances; vacation.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 42 Public Health 1 2013-10-01 2013-10-01 false Benefits: Stipends; dependency allowances; travel...; dependency allowances; travel allowances; vacation. Individuals awarded regular fellowships shall be entitled...) Stipend. (b) Dependency allowances. (c) When authorized in advance, separate allowances for travel. Such...

  11. Thermodynamic Pressure/Temperature Transducer Health Check

    NASA Technical Reports Server (NTRS)

    Immer, Christopher D. (Inventor); Eckhoff, Anthony (Inventor); Medelius, Pedro J. (Inventor); Deyoe, Richard T. (Inventor); Starr, Stanley O. (Inventor)

    2004-01-01

    A device and procedure for checking the health of a pressure transducer in situ is provided. The procedure includes measuring a fixed change in pressure above ambient pressure and a fixed change in pressure below ambient pressure. This is done by first sealing an enclosed volume around the transducer with a valve. A piston inside the sealed volume is increasing the pressure. A fixed pressure below ambient pressure is obtained by opening the valve, driving the piston The output of the pressure transducer is recorded for both the overpressuring and the underpressuring. By comparing this data with data taken during a preoperative calibration, the health of the transducer is determined from the linearity, the hysteresis, and the repeatability of its output. The further addition of a thermometer allows constant offset error in the transducer output to be determined.

  12. Fast pressure-sensor system

    NASA Technical Reports Server (NTRS)

    Gross, C.

    1976-01-01

    Miniature silicon-diaphragm sensors and signal multiplexer are mounted to ganged zero-operate-calibrate pressure selector switches. Device allows in-situ calibration, can be computer controlled, and measures at approximately 10,000 readings per second.

  13. Unsteady pressure measurement instrumentation using anodized-aluminium PSP applied in a transonic wind tunnel

    NASA Astrophysics Data System (ADS)

    Mérienne, Marie-Claire; LeSant, Yves; Ancelle, Jacques; Soulevant, Didier

    2004-12-01

    The objective of this work is to demonstrate the feasibility of pressure measurement instrumentation using anodized-aluminium pressure-sensitive paint (or AA-PSP) for application in unsteady flows. An anodized procedure was applied to an aluminium tape that can be easily placed on a model even when it is mounted in a wind tunnel. The response time of the PSP coating is assessed using a calibration rig that generates fast pressure steps or sinusoidal pressure fluctuations up to 1 kHz. A pointwise measurement system made with a Cassegrain telescope and a photomultiplier tube was designed to collect the PSP luminescence. The spot displacement on the model surface was carried out by using a 3D moving bench. A camera is used to identify the spot position according to the model geometry. An application in a wind tunnel was performed on a forced shock wave oscillation test, generating amplitude variations up to 25 kPa. The calibration problem due to non-uniformity of the anodized properties did not allow quantitative data processing of pressure levels. Nevertheless frequency analysis demonstrates that the coating is able to follow the pressure fluctuations, as shown by comparison with standard pressure transducers.

  14. Domestic atmospheric pressure thermal deaerators

    NASA Astrophysics Data System (ADS)

    Egorov, P. V.; Gimmelberg, A. S.; Mikhailov, V. G.; Baeva, A. N.; Chuprakov, M. V.; Grigoriev, G. V.

    2016-04-01

    Based on many years of experience and proven technical solutions, modern atmospheric pressure deaerators of the capacity of 0.4 to 800 t/h were designed and developed. The construction of such deaerators is based on known and explored technical solutions. A two-stage deaeration scheme is applied where the first stage is a jet dripping level (in a column) and the second one is a bubble level (in a tank). In the design of deaeration columns, low-pressure hydraulic nozzles (Δ p < 0.15 MPa) and jet trays are used, and in deaerator tank, a developed "flooded" sparger is applied, which allows to significantly increase the intensity of the heat and mass exchange processes in the apparatus. The use of the two efficient stages in a column and a "flooded" sparger in a tank allows to reliably guarantee the necessary water heating and deaeration. Steam or "superheated" water of the temperature of t ≥ 125°C can be used as the coolant in the deaerators. The commissioning tests of the new deaerator prototypes of the capacity of 800 and 500 t/h in the HPP conditions showed their sustainable, reliable, and efficient work in the designed range of hydraulic and thermal loads. The content of solved oxygen and free carbon dioxide in make-up water after deaerators meets the requirements of State Standard GOST 16860-88, the operating rules and regulations, and the customer's specifications. Based on these results, the proposals were developed on the structure and the design of deaerators of the productivity of more than 800 t/h for the use in circuits of large heating systems and the preparation of feed water to the TPP at heating and industrial-heating plants. The atmospheric pressure thermal deaerators developed at NPO TsKTI with consideration of the current requirements are recommended for the use in water preparation schemes of various power facilities.

  15. [The effects of work in an air-conditioned cabin and stay in a resting chamber on blood pressure and heart rate of operators employed in deep copper mines].

    PubMed

    Borodulin-Nadzieja, L; Janocha, A; Pietraszkiewicz, T; Salomon, E; Stańda, M

    2001-01-01

    This paper is part of a wider comparative study of the heart rate, blood pressure, external and core temperature in operators of self-propelled mining machines with and without air-conditioning cabins. Two groups, each of ten operators, characterised by the similar age and duration of employment, stayed for 20 min a specially prepared resting chamber with much more advantageous microclimatic conditions. The results of our examinations (Holter heart rate and continuous blood pressure recordings, external and core temperature measurements) revealed that during the work (particularly during the increased work-load) all parameters recorded were significantly lower in air-conditioning cabins as compared with the group working without air-condition. In both groups, a complete restitution of the heart rate and blood pressure was observed after a 20-min stay in the resting chamber. During the work, a statistically significant increase in the external temperature was found in both groups of operators, whereas the increase in the core temperature was observed only in operators working without air-condition. After a 20-min stay in the resting chamber, a complete return to the normal temperature was noted only in operators working in air-conditioned cabins.

  16. Pressure Measurement Systems

    NASA Astrophysics Data System (ADS)

    1990-01-01

    System 8400 is an advanced system for measurement of gas and liquid pressure, along with a variety of other parameters, including voltage, frequency and digital inputs. System 8400 offers exceptionally high speed data acquisition through parallel processing, and its modular design allows expansion from a relatively inexpensive entry level system by the addition of modular Input Units that can be installed or removed in minutes. Douglas Juanarena was on the team of engineers that developed a new technology known as ESP (electronically scanned pressure). The Langley ESP measurement system was based on miniature integrated circuit pressure-sensing transducers that communicated pressure information to a minicomputer. In 1977, Juanarena formed PSI to exploit the NASA technology. In 1978 he left Langley, obtained a NASA license for the technology, introduced the first commercial product, the 780B pressure measurement system. PSI developed a pressure scanner for automation of industrial processes. Now in its second design generation, the DPT-6400 is capable of making 2,000 measurements a second and has 64 channels by addition of slave units. New system 8400 represents PSI's bid to further exploit the 600 million U.S. industrial pressure measurement market. It is geared to provide a turnkey solution to physical measurement.

  17. Spacecraft Minimum Allowable Concentrations: Determination, Application, and Contingency Situations

    NASA Technical Reports Server (NTRS)

    Marshburn, Thomas H.; Dawson, David L. (Technical Monitor)

    1999-01-01

    This document is an outline of a presentation about the determination of minimum allowable concentrations in spacecraft. The presentation reviews the type of toxins and mechanisms to determine the acceptable concentrations of these toxic substances. The considerations for the unique situation that spaceflight entails including zero gravity, and the intense scrutiny are reviewed. The current measurement hardware is reviewed. The spacecraft atmospheres on the Shuttle, airflow, the Space Station and the EMU in respect to airflow, pressure, constituents are also summarized. Contingency situations and potential hazards are also discussed.

  18. [Demographic pressure, "informal sector" and technological choices in Third World countries].

    PubMed

    Hugon, P

    1983-01-01

    Trisectorial models of economic functioning have been proposed to replace the dualistic models that proved incapable of illuminating postwar employment trends in developing countries. The new models propose 3 sectors: the subsistence sector, where average productivity corresponds to the subsistence minimum and which is thus incapable of generating a surplus for savings; the intermediate sector, weakly capitalistic, characterized by the absence of a permanent salaried work force or codified labor relations, in which precariousness of employment and the exploitation of specific social relations allow a low wage rate, with a concommitant mode of regulation that largely escapes state control; and the intensely capitalistic sector, with a salaried work force, codified labor relations, existence of administered prices, various state subventions and protections and a monopolistic type of regulation. The 3 sectors are described in greater detail and represented graphically, along with a critique of the limitations of most studies employing a trisectorial perspective. A study of the impact of demographic pressure at different levels of technology embedded in specific sociohistoric systems follows. The final section contains an analysis of 3 types of effects which may mediate the role of demographic pressure in the choice of technologies: effects of demographic pressure on structures of production and consumption, on segments of the labor force, and on involutive and evolutive processes. It is argued that the links between demographic pressure, technologic choices, and the productive sector can only be analyzed in specific social systems.

  19. A pressure ulcer prevention programme specially designed for nursing homes: does it work?

    PubMed

    Kwong, Enid W-Y; Lau, Ada T-Y; Lee, Rainbow L-P; Kwan, Rick Y-C

    2011-10-01

    The aim of this study was to evaluate a pressure ulcer prevention programme for nursing homes to ascertain the feasibility of its implementation, impact on care staff and outcomes for pressure ulcer knowledge and skills and pressure ulcer reduction. No pressure ulcer prevention protocol for long-term care settings has been established to date. The first author of this study thus developed a pressure ulcer prevention programme for nursing homes. A quasi-experimental pretest and post-test design was adopted. Forty-one non-licensed care providers and eleven nurses from a government-subsidised nursing home voluntarily participated in the study. Knowledge and skills of the non-licensed care providers were assessed before, immediately after and six weeks after the training course, and pressure ulcer prevalence and incidence were recorded before and during the protocol implementation. At the end of the programme implementation, focus group interviews with the subjects were conducted to explore their views on the programme. A statistically significant improvement in knowledge and skills scores amongst non-licensed care providers was noted. Pressure ulcer prevalence and incidence rates dropped from 9-2·5% and 2·5-0·8%, respectively, after programme implementation. The focus group findings indicated that the programme enhanced the motivation of non-licensed care providers to improve their performance of pressure ulcer prevention care and increased communication and cooperation amongst care staff, but use of the modified Braden scale was considered by nurses to increase their workload. A pressure ulcer prevention programme for nursing homes, which was feasible and acceptable, with positive impact and outcome in a nursing home was empirically developed. The study findings can be employed to modify the programme and its outcomes for an evaluation of effectiveness of the programme through a randomised controlled trial. © 2011 Blackwell Publishing Ltd.

  20. Testing of Confining Pressure Impacton Explosion Energy of Explosive Materials

    NASA Astrophysics Data System (ADS)

    Drzewiecki, Jan; Myszkowski, Jacek; Pytlik, Andrzej; Pytlik, Mateusz

    2017-06-01

    This paper presents the results of testing the explosion effects of two explosive charges placed in an environment with specified values of confining pressure. The aim of this study is to determine the impact of variable environmental conditions on the suitability of particular explosives for their use in the prevention of natural hazards in hard coal mining. The research results will contribute to improving the efficiency of currently adopted technologies of natural hazard prevention and aid in raising the level of occupational safety. To carry out the subject matter measurements, a special test stand was constructed which allows the value of the initial pressure inside the chamber, which constitutes its integral part, to be altered before the detonation of the charge being tested. The obtained characteristics of the pressure changes during the explosion of the analysed charge helped to identify the work (energy) which was produced during the process. The test results are a valuable source of information, opening up new possibilities for the use of explosives, the development of innovative solutions for the construction of explosive charges and their initiation.

  1. 76 FR 45697 - Vocational Rehabilitation and Employment Program-Changes to Subsistence Allowance

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-01

    ... under chapter 31 includes on-job training and non-paid work experience, during which an employer or... allow payment of the Post-9/11 subsistence allowance for veterans who are participating in on-job.... We retain the rule with respect to payment of the current subsistence allowance for on-job training...

  2. Arterial Pressure Analog.

    ERIC Educational Resources Information Center

    Heusner, A. A.; Tracy, M. L.

    1980-01-01

    Describes a simple hydraulic analog which allows students to explore some physical aspects of the cardiovascular system and provides them with a means to visualize and conceptualize these basic principles. Simulates the behavior of arterial pressure in response to changes in heart rate, stroke volume, arterial compliance, and peripheral…

  3. Work Capability and physiological effects predictive studies. 4: In He-O2 excursions to pressures of 400- 800- 1200- and 1600 feet of sea water

    NASA Technical Reports Server (NTRS)

    Lambertsen, C. J. (Editor); Gelfand, R. (Editor); Clark, J. M. (Editor); Fletcher, M. E. (Editor)

    1978-01-01

    Experiments which exposed men in chambers, breathing helium with oxygen, to progressive increases of pressure equivalent to 400-800-1200-1600 feet of sea water (fsw) were conducted. Rates of compression and exposure to stable high pressure. Goals included: 1) determination of the specific character and time course of onset of physiological and performance decrements during the intentionally rapid compressions, and determination of rates of adaptation on reaching stable elevated pressure; 2) investigation of accelerated methods for decompression in deep saturation excursion diving; and 3) determination of competence in practical work performed in water at pressures equivalent to the extreme diving depths of 1200 and 1600 fsw.

  4. Two-tank working gas storage system for heat engine

    DOEpatents

    Hindes, Clyde J.

    1987-01-01

    A two-tank working gas supply and pump-down system is coupled to a hot gas engine, such as a Stirling engine. The system has a power control valve for admitting the working gas to the engine when increased power is needed, and for releasing the working gas from the engine when engine power is to be decreased. A compressor pumps the working gas that is released from the engine. Two storage vessels or tanks are provided, one for storing the working gas at a modest pressure (i.e., half maximum pressure), and another for storing the working gas at a higher pressure (i.e., about full engine pressure). Solenoid valves are associated with the gas line to each of the storage vessels, and are selectively actuated to couple the vessels one at a time to the compressor during pumpdown to fill the high-pressure vessel with working gas at high pressure and then to fill the low-pressure vessel with the gas at low pressure. When more power is needed, the solenoid valves first supply the low-pressure gas from the low-pressure vessel to the engine and then supply the high-pressure gas from the high-pressure vessel. The solenoid valves each act as a check-valve when unactuated, and as an open valve when actuated.

  5. Comparison of Two Types of Insoles on Musculoskeletal Symptoms and Plantar Pressure Distribution in a Work Environment: A Randomized Clinical Trial.

    PubMed

    Almeida, Josiane S; Vanderlei, Franciele M; Pastre, Eliane C; Martins, Rodrigo A D M; Padovani, Carlos R; Filho, Guaracy C

    2016-06-01

    The aim of the present study was to assess plantar pressure distribution and musculoskeletal symptoms following the use of customized insoles among female assembly line workers. The study included 29 female assembly line workers (age, 29.76 ± 5.79 years; weight, 63.79 ± 12.11 kg) with musculoskeletal symptoms who work predominantly while standing. The Nordic Musculoskeletal Questionnaire was administered to the study population. Plantar pressure was determined using a computerized plantar pressure feedback system. A control group (n=13) used ethylvinylacetate insoles (Podaly®) that were individually heat molded and heat glued. The intervention group (n=14) also used the insoles and a strip of the same material was added to the site of greatest plantar pressure as determined by the electronic feedback device. After five weeks, the plantar pressure data were collected again and the questionnaire was administered a second time. There was no significant difference between groups with regard to pain in any anatomic site. However, within each group the lumbar region exhibited a reduction in symptoms in the intervention group (P<0.05), and the feet exhibited a reduction in symptoms in both groups (P<0.05). Mean plantar pressure increased and plantar surface decreased in the intervention group (P<0.05). Insoles increased foot comfort in both groups. However, the added strip did not significantly modify either plantar pressure or other symptoms in female workers. © 2016 Marshfield Clinic.

  6. Intra-ocular pressure normalization technique and equipment

    NASA Technical Reports Server (NTRS)

    Baehr, E. F. (Inventor)

    1979-01-01

    A method and apparatus is described for safely reducing abnormally high intraocular pressure in an eye during a predetermined time interval. This allows maintenance of normal intraocular pressure during glaucoma surgery. A pressure regulator of the spring-biassed diaphragm type is provided with additional bias by a column of liquid. The hypodermic needle can be safely inserted into the anterior chamber of the eye. Liquid is then bled out of the column to reduce the bias on the diaphragm of the pressure regulator and, consequently, the output pressure of the regulator. This lowering pressure of the regulator also occurs in the eye by means of a small second bleed path provided between the pressure regulator and the hypodermic needle.

  7. Household responsibilities, income, and ambulatory blood pressure among working men and women

    PubMed Central

    Thurston, Rebecca C.; Sherwood, Andrew; Matthews, Karen A.; Blumenthal, James A.

    2011-01-01

    Objective To test the hypothesis that a greater perceived responsibility for household tasks and a greater number of hours spent doing these tasks would be associated with elevated ambulatory systolic (SBP) and diastolic blood pressure (DBP). The connection between job characteristics and cardiovascular outcomes has been widely studied. However, less is known about links between household work characteristics and cardiovascular health. Methods 113 employed unmedicated hypertensive men and women underwent one day of ambulatory blood pressure (ABP) monitoring. Participants provided information on 1) the number of hours spent doing and 2) their degree of responsibility for seven household tasks (child care, pet care, caring for ill/elderly, household chores, house/car repair, yardwork, finances). Associations between task hours and responsibility ratings in relation to SBP and DBP were estimated using generalized estimating equations, with covariates age, race, gender, body mass index, location, posture. Interactions with gender and socioeconomic position were assessed. Results A greater perceived responsibility for household tasks, but not the hours spent doing these tasks, was associated with higher ambulatory SBP (b(95% confidence interval (CI))=0.93(0.29–1.56), p=0.004) and DBP (b(95%CI)=0.30(0.10–0.51), p=0.003)). Significant interactions with income indicated that associations between household responsibilities and ABP were most pronounced among low income participants (SBP: b(95%CI)=1.40(0.58–2.21), p<0.001; DBP: b(95%CI)=0.48(0.18–0.78), p<0.01). The task most strongly associated with BP was household chores. No interactions with gender were observed. Conclusions Greater perceived responsibility for household tasks was associated with elevated ABP, particularly for lower income participants. Household obligations may have important implications for cardiovascular health, meriting further empirical attention. PMID:21217097

  8. Negative pressure wound treatment improves Acute Physiology and Chronic Health Evaluation II score in mediastinitis allowing a successful elective pectoralis muscle flap closure: six-year experience of a single protocol.

    PubMed

    Salica, Andrea; Weltert, Luca; Scaffa, Raffaele; Guerrieri Wolf, Lorenzo; Nardella, Saverio; Bellisario, Alessandro; De Paulis, Ruggero

    2014-11-01

    Optimal management of poststernotomy mediastinitis is controversial. Negative pressure wound treatment improves wound environment and sternal stability with low surgical invasiveness. Our protocol was based on negative pressure followed by delayed surgical closure. The aim of this study was to provide the results at early follow-up and to identify the risk factors for adverse outcome. In 5400 cardiac procedures, 44 consecutive patients with mediastinitis were enrolled in the study. Mediastinitis treatment was based on urgent debridement and negative pressure as the first-line approach. After wound sterilization, chest closure was achieved by elective pectoralis muscle advancement flap. Each patient's hospital data were collected prospectively. Variables included patient demographics and clinical and biological data. Acute Physiology and Chronic Health Evaluation (APACHE) II score was calculated at the time of diagnosis and 48 hours after debridement. Focus outcome measures were mediastinitis-related death and need for reintervention after pectoralis muscle closure. El Oakley type I and type IIIA mediastinitis were the most frequent types (63.6%). Methicillin-resistant Staphylococcus aureus was present in 25 patients (56.8%). Mean APACHE II score was 19.4±4 at the time of diagnosis, and 30 patients (68.2%) required intensive care unit transfer before surgical debridement. APACHE II score improved 48 hours after wound debridement and negative pressure application (mean value, 19.4±4 vs 7.2±2; P=.005) independently of any other variables included in the study. One patient in septic shock at the time of diagnosis died (2.2%). Negative pressure promotes a significant improvement in clinical status according to APACHE II score and allows a successful elective surgical closure. Copyright © 2014 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.

  9. A dynamic pressure source for the calibration of pressure transducers

    NASA Technical Reports Server (NTRS)

    Vezzetti, C. F.; Hilten, J. S.; Mayo-Wells, J. F.; Lederer, P. S.

    1976-01-01

    A dynamic pressure source is described for producing sinusoidally varying pressures of up to 34 kPa zero to peak, over the frequency range of approximately 50 Hz to 2 kHz. The source is intended for the dynamic calibration of pressure transducers. The transducer to be calibrated is mounted near the base of the thick walled aluminum tube forming the vessel so that the pressure sensitive element is in contact with the liquid in the tube. A section of the tube is filled with small steel balls to damp the motion of the 10-St dimethyl siloxane working fluid in order to extend the useful frquency range to higher frequencies than would be provided by an undamped system. The dynamic response of six transducers provided by the sponsor was evaluated using the pressure sources; the results of these calibrations are given.

  10. Psychosocial factors in GP work: the effects of taking a GP position or leaving GP work.

    PubMed

    Heponiemi, Tarja; Kouvonen, Anne; Aalto, Anna-Mari; Elovainio, Marko

    2013-06-01

    We examined the effects of leaving public sector general practitioner (GP) work and of taking a GP position on changes in work-related psychosocial factors, such as time pressure, patient-related stress, distress and work interference with family. In addition, we examined whether changes in time pressure and patient-related stress mediated the association of employment change with changes of distress and work interference with family. Participants were 1705 Finnish physicians (60% women) who responded to surveys in 2006 and 2010. Analyses of covariance were conducted to examine the effect of employment change to outcome changes adjusted for gender, age and response format. Mediational effects were tested following the procedures outlined by Baron and Kenny. Employment change was significantly associated with all the outcomes. Leaving public sector GP work was associated with substantially decreased time pressure, patient-related stress, distress and work interference with family. In contrast, taking a position as a public sector GP was associated with an increase in these factors. Mediation tests suggested that the associations of employment change with distress change and work interference with family change were partially explained by the changes in time pressure and patient-related stress. Our results showed that leaving public sector GP work is associated with favourable outcomes, whereas taking a GP position in the public sector is associated with adverse effects. Primary health-care organizations should pay more attention to the working conditions of their GPs, in particular, to time pressure and patient-related stress.

  11. Longitudinal Associations between Maternal Work Stress, Negative Work-Family Spillover, and Depressive Symptoms

    PubMed Central

    Goodman, W. Benjamin; Crouter, Ann C.

    2009-01-01

    The current study examined associations over an 18-month period between maternal work stressors, negative work-family spillover, and depressive symptoms in a sample of 414 employed mothers with young children living in six predominantly nonmetropolitan counties in the Eastern United States. Results from a one-group mediation model revealed that a less flexible work environment and greater work pressure predicted higher levels of depressive symptoms, and further, that these associations were mediated by perceptions of negative work-family spillover. Additionally, results from a two-group mediation model suggested that work pressure predicted greater perceptions of spillover only for mothers employed full-time. Findings suggest the need for policies that reduce levels of work stress and help mothers manage their work and family responsibilities. PMID:20161088

  12. Longitudinal Associations between Maternal Work Stress, Negative Work-Family Spillover, and Depressive Symptoms.

    PubMed

    Goodman, W Benjamin; Crouter, Ann C

    2009-07-01

    The current study examined associations over an 18-month period between maternal work stressors, negative work-family spillover, and depressive symptoms in a sample of 414 employed mothers with young children living in six predominantly nonmetropolitan counties in the Eastern United States. Results from a one-group mediation model revealed that a less flexible work environment and greater work pressure predicted higher levels of depressive symptoms, and further, that these associations were mediated by perceptions of negative work-family spillover. Additionally, results from a two-group mediation model suggested that work pressure predicted greater perceptions of spillover only for mothers employed full-time. Findings suggest the need for policies that reduce levels of work stress and help mothers manage their work and family responsibilities.

  13. 20 CFR 668.350 - Are there any restrictions on allowable activities?

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... working a similar length of time and doing the same type of work. (WIA sec. 181(b)(5).) (c) In addition... conditions at the same level and to the same extent as other employees working a similar length of time and... 20 Employees' Benefits 3 2010-04-01 2010-04-01 false Are there any restrictions on allowable...

  14. Effects of working gas pressure on zirconium dioxide thin film prepared by pulsed plasma deposition: roughness, wettability, friction and wear characteristics.

    PubMed

    Berni, M; Marchiori, G; Gambardella, A; Boi, M; Bianchi, M; Russo, A; Visani, A; Marcacci, M; Pavan, P G; Lopomo, N F

    2017-08-01

    In joint arthroplasty one of the main issues related to the failure of prosthetic implants is due to the wear of the ultra-high molecular weight polyethylene (UHMWPE) component. Surface treatments and coatings have been recognized as enhancing methods, able to improve the tribological properties of the implants. Therefore, the main objective of this work was to investigate the possibility to fabricate yttria-stabilized zirconia (YSZ) coatings on a metal (AISI 316-L) substrate by means of Pulsed Electron Deposition, in order to improve the tribological behavior of the polymer-metal coupling, by reducing the initial wear of the UHMWPE component. In order to optimize the coating characteristics, the effects of working gas pressure on both its morphological and tribological properties were analyzed. Morphological characterization of the films was evaluated by Atomic Force Microscopy (AFM). Coating wettability was also estimated by contact angle (CA) measurement. Tribological performance (coupling friction and wear of UHMWPE) was evaluated by using a ball-on-disc tribometer during highly-stressing tests in dry and lubricated (i.e. NaCl and serum) conditions; friction and wear were specifically evaluated at the initial sliding distances - to highlight the main effect of coating morphology - and after 100m - where the influence of the intrinsic materials properties prevails. AFM analysis highlighted that the working pressure heavily affected the morphological characteristics of the realized films. The wettability of the coating at the highest and lowest deposition pressures (CA ~ 60°, closed to substrate value) decreased for intermediate pressures, reaching a maximum CA of ~ 90°. Regarding tribological tests, a strong correlation was found in the initial steps between friction coefficient and wettability, which decreased as the distance increased. Concerning UHMWPE wear associated to coated counterpart, at 100m a reduction rate of about 7% in dry, 12% in NaCl and 5% in

  15. Pressure mapping with textile sensors for compression therapy monitoring.

    PubMed

    Baldoli, Ilaria; Mazzocchi, Tommaso; Paoletti, Clara; Ricotti, Leonardo; Salvo, Pietro; Dini, Valentina; Laschi, Cecilia; Francesco, Fabio Di; Menciassi, Arianna

    2016-08-01

    Compression therapy is the cornerstone of treatment in the case of venous leg ulcers. The therapy outcome is strictly dependent on the pressure distribution produced by bandages along the lower limb length. To date, pressure monitoring has been carried out using sensors that present considerable drawbacks, such as single point instead of distributed sensing, no shape conformability, bulkiness and constraints on patient's movements. In this work, matrix textile sensing technologies were explored in terms of their ability to measure the sub-bandage pressure with a suitable temporal and spatial resolution. A multilayered textile matrix based on a piezoresistive sensing principle was developed, calibrated and tested with human subjects, with the aim of assessing real-time distributed pressure sensing at the skin/bandage interface. Experimental tests were carried out on three healthy volunteers, using two different bandage types, from among those most commonly used. Such tests allowed the trends of pressure distribution to be evaluated over time, both at rest and during daily life activities. Results revealed that the proposed device enables the dynamic assessment of compression mapping, with a suitable spatial and temporal resolution (20 mm and 10 Hz, respectively). In addition, the sensor is flexible and conformable, thus well accepted by the patient. Overall, this study demonstrates the adequacy of the proposed piezoresistive textile sensor for the real-time monitoring of bandage-based therapeutic treatments. © IMechE 2016.

  16. Pressure ulcer prevention program: a journey.

    PubMed

    Delmore, Barbara; Lebovits, Sarah; Baldock, Philip; Suggs, Barbara; Ayello, Elizabeth A

    2011-01-01

    The Centers for Medicare & Medicaid Services' regulations regarding nonpayment for hospital-acquired conditions such as pressure ulcers have prompted a marked increase in focus on preventive care. Our hospital also used this change in payment policy as an opportunity to strengthen our pressure ulcer prevention practices. We used an 8-spoke prevention wheel to develop and implement practice changes that reduced pressure ulcer incidence from 7.3% to 1.3% in 3 years. Because it is about the journey, we will describe the mechanisms we designed and implemented, and identify strategies that worked or did not work as we promulgated a quality improvement process for pressure ulcer prevention in our large urban hospital center.

  17. On the internal structure of relativistic jets collimated by ambient gas pressure

    NASA Astrophysics Data System (ADS)

    Beskin, V. S.; Chernoglazov, A. V.; Kiselev, A. M.; Nokhrina, E. E.

    2017-12-01

    Recent progress in very long baseline interferometry (VLBI) observations of relativistic jets outflowing from active galactic nuclei gives us direct information about jet width rjet(l) dependence on the distance l from the 'central engine'. Being the missing link in previous works, this relation opens the possibility of determining the internal structure of a jet. In this article, we consider a relativistic jet submerged in an external medium with finite gas pressure Pext. Neither an external magnetic field nor an infinitely thin current sheet will be assumed. This approach allows us to construct a reasonable solution in which both the magnetic field and the flow velocity vanish at the jet boundary r = rjet. In particular, the connection between external gas pressure and internal structure of a relativistic jet is determined.

  18. Test of FBG sensors for monitoring high pressure pipes

    NASA Astrophysics Data System (ADS)

    Paolozzi, Antonio; Paris, Claudio; Vendittozzi, Cristian; Felli, Ferdinando; Mongelli, Marialuisa; De Canio, Gerardo; Colucci, Alessandro; Asanuma, Hiroshi

    2017-04-01

    Fibre Bragg Grating (FBG) sensors are increasingly being used on a wide range of civil, industrial and aerospace structures. The sensors are created inside optical fibres (usually standard telecommunication fibres); the optical fibres technology allows to install the sensors on structures working in harsh environments, since the materials are almost insensitive to corrosion, the monitoring system can be positioned far away from the sensors without sensible signal losses, and there is no risk of electric discharge. FBG sensors can be used to create strain gages, thermometers or accelerometers, depending on the coating on the grating, on the way the grating is fixed to the structure, and on the presence of a specifically designed interface that can act as a transducer. This paper describes a test of several different FBG sensors to monitor an high pressure pipe that feeds the hydraulic actuators of a 6 degrees-of-freedom shaking table at the ENEA Casaccia research centre. A bare FBG sensor and a copper coated FBG sensor have been glued on the pipe. A third sensor has been mounted on a special interface to amplify the vibrations; this last sensor can be placed on the steel pipe by a magnetic mounting system, that also allows the its removal. All the sensor are placed parallel to the axis of the pipe. The analysis of the data recorded when the shaking table is operated will allow to determine which kind of sensor is best suited for structural monitoring of high pressure pipelines.

  19. Beat-to-Beat Blood Pressure Monitor

    NASA Technical Reports Server (NTRS)

    Lee, Yong Jin

    2012-01-01

    This device provides non-invasive beat-to-beat blood pressure measurements and can be worn over the upper arm for prolonged durations. Phase and waveform analyses are performed on filtered proximal and distal photoplethysmographic (PPG) waveforms obtained from the brachial artery. The phase analysis is used primarily for the computation of the mean arterial pressure, while the waveform analysis is used primarily to obtain the pulse pressure. Real-time compliance estimate is used to refine both the mean arterial and pulse pressures to provide the beat-to-beat blood pressure measurement. This wearable physiological monitor can be used to continuously observe the beat-to-beat blood pressure (B3P). It can be used to monitor the effect of prolonged exposures to reduced gravitational environments and the effectiveness of various countermeasures. A number of researchers have used pulse wave velocity (PWV) of blood in the arteries to infer the beat-to-beat blood pressure. There has been documentation of relative success, but a device that is able to provide the required accuracy and repeatability has not yet been developed. It has been demonstrated that an accurate and repeatable blood pressure measurement can be obtained by measuring the phase change (e.g., phase velocity), amplitude change, and distortion of the PPG waveforms along the brachial artery. The approach is based on comparing the full PPG waveform between two points along the artery rather than measuring the time-of-flight. Minimizing the measurement separation and confining the measurement area to a single, well-defined artery allows the waveform to retain the general shape between the two measurement points. This allows signal processing of waveforms to determine the phase and amplitude changes.

  20. Observations of Fabric Development in Polycrystalline Ice at Basal Pressures: Methods and Initial Results

    NASA Astrophysics Data System (ADS)

    Breton, D. J.; Baker, I.; Cole, D. M.

    2012-12-01

    Understanding and predicting the flow of polycrystalline ice is crucial to ice sheet modeling and paleoclimate reconstruction from ice cores. Ice flow rates depend strongly on the fabric (i.e. the distribution of grain sizes and crystallographic orientations) which evolves over time and enhances the flow rate in the direction of applied stress. The mechanisms for fabric evolution in ice have been extensively studied at atmospheric pressures, but little work has been done to observe these processes at the high pressures experienced deep within ice sheets where long-term changes in ice rheology are expected to have significance. We conducted compressive creep tests on a 917 kg m-3 polycrystalline ice specimen at 20 MPa hydrostatic pressure, thus simulating ~2,000 m depth. Initial specimen grain orientations were random, typical grain diameters were 1.2 mm, and the applied creep stress was 0.3 MPa. Subsequent microstructural analyses on the deformed specimen and a similarly prepared, undeformed specimen allowed characterization of crystal fabric evolution under pressure. Our microstructural analysis technique simultaneously collected grain shape and size data from Scanning Electron Microscope (SEM) micrographs and obtained crystallographic orientation data via Electron BackScatter Diffraction (EBSD). Combining these measurements allows rapid analysis of the ice fabric over large numbers of grains, yielding statistically useful numbers of grain size and full c- and a-axis grain orientation data. The combined creep and microstructural data demonstrate pressure-dependent effects on the mechanical and microstructural evolution of polycrystalline ice. We discuss possible mechanisms for the observed phenomena, and future directions for hydrostatic creep testing.

  1. ADDITIONAL STRESS AND FRACTURE MECHANICS ANALYSES OF PRESSURIZED WATER REACTOR PRESSURE VESSEL NOZZLES

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Walter, Matthew; Yin, Shengjun; Stevens, Gary

    2012-01-01

    In past years, the authors have undertaken various studies of nozzles in both boiling water reactors (BWRs) and pressurized water reactors (PWRs) located in the reactor pressure vessel (RPV) adjacent to the core beltline region. Those studies described stress and fracture mechanics analyses performed to assess various RPV nozzle geometries, which were selected based on their proximity to the core beltline region, i.e., those nozzle configurations that are located close enough to the core region such that they may receive sufficient fluence prior to end-of-life (EOL) to require evaluation of embrittlement as part of the RPV analyses associated with pressure-temperaturemore » (P-T) limits. In this paper, additional stress and fracture analyses are summarized that were performed for additional PWR nozzles with the following objectives: To expand the population of PWR nozzle configurations evaluated, which was limited in the previous work to just two nozzles (one inlet and one outlet nozzle). To model and understand differences in stress results obtained for an internal pressure load case using a two-dimensional (2-D) axi-symmetric finite element model (FEM) vs. a three-dimensional (3-D) FEM for these PWR nozzles. In particular, the ovalization (stress concentration) effect of two intersecting cylinders, which is typical of RPV nozzle configurations, was investigated. To investigate the applicability of previously recommended linear elastic fracture mechanics (LEFM) hand solutions for calculating the Mode I stress intensity factor for a postulated nozzle corner crack for pressure loading for these PWR nozzles. These analyses were performed to further expand earlier work completed to support potential revision and refinement of Title 10 to the U.S. Code of Federal Regulations (CFR), Part 50, Appendix G, Fracture Toughness Requirements, and are intended to supplement similar evaluation of nozzles presented at the 2008, 2009, and 2011 Pressure Vessels and Piping (PVP

  2. Deciphering the adaptation strategies of Desulfovibrio piezophilus to hydrostatic pressure through metabolic and transcriptional analyses.

    PubMed

    Amrani, Amira; van Helden, Jacques; Bergon, Aurélie; Aouane, Aicha; Ben Hania, Wajdi; Tamburini, Christian; Loriod, Béatrice; Imbert, Jean; Ollivier, Bernard; Pradel, Nathalie; Dolla, Alain

    2016-08-01

    Desulfovibrio piezophilus strain C1TLV30(T) is a mesophilic piezophilic sulfate-reducer isolated from Wood Falls at 1700 m depth in the Mediterranean Sea. In this study, we analysed the effect of the hydrostatic pressure on this deep-sea living bacterium at the physiologic and transcriptomic levels. Our results showed that lactate oxidation and energy metabolism were affected by the hydrostatic pressure. Especially, acetyl-CoA oxidation pathway and energy conservation through hydrogen and formate recycling would be more important when the hydrostatic pressure is above (26 MPa) than below (0.1 MPa) the optimal one (10 MPa). This work underlines also the role of the amino acid glutamate as a piezolyte for the Desulfovibrio genus. The transcriptomic analysis revealed 146 differentially expressed genes emphasizing energy production and conversion, amino acid transport and metabolism and cell motility and signal transduction mechanisms as hydrostatic pressure responding processes. This dataset allowed us to identify a sequence motif upstream of a subset of differentially expressed genes as putative pressure-dependent regulatory element. © 2016 Society for Applied Microbiology and John Wiley & Sons Ltd.

  3. Pressure Ratio to Thermal Environments

    NASA Technical Reports Server (NTRS)

    Lopez, Pedro; Wang, Winston

    2012-01-01

    A pressure ratio to thermal environments (PRatTlE.pl) program is a Perl language code that estimates heating at requested body point locations by scaling the heating at a reference location times a pressure ratio factor. The pressure ratio factor is the ratio of the local pressure at the reference point and the requested point from CFD (computational fluid dynamics) solutions. This innovation provides pressure ratio-based thermal environments in an automated and traceable method. Previously, the pressure ratio methodology was implemented via a Microsoft Excel spreadsheet and macro scripts. PRatTlE is able to calculate heating environments for 150 body points in less than two minutes. PRatTlE is coded in Perl programming language, is command-line-driven, and has been successfully executed on both the HP and Linux platforms. It supports multiple concurrent runs. PRatTlE contains error trapping and input file format verification, which allows clear visibility into the input data structure and intermediate calculations.

  4. Nurses' work demands and work-family conflict: a questionnaire survey.

    PubMed

    Yildirim, Dilek; Aycan, Zeynep

    2008-09-01

    Work-family conflict is a type of interrole conflict that occurs as a result of incompatible role pressures from the work and family domains. Work role characteristics that are associated with work demands refer to pressures arising from excessive workload and time pressures. Literature suggests that work demands such as number of hours worked, workload, shift work are positively associated with work-family conflict, which, in turn is related to poor mental health and negative organizational attitudes. The role of social support has been an issue of debate in the literature. This study examined social support both as a moderator and a main effect in the relationship among work demands, work-to-family conflict, and satisfaction with job and life. This study examined the extent to which work demands (i.e., work overload, irregular work schedules, long hours of work, and overtime work) were related to work-to-family conflict as well as life and job satisfaction of nurses in Turkey. The role of supervisory support in the relationship among work demands, work-to-family conflict, and satisfaction with job and life was also investigated. The sample was comprised of 243 participants: 106 academic nurses (43.6%) and 137 clinical nurses (56.4%). All of the respondents were female. The research instrument was a questionnaire comprising nine parts. The variables were measured under four categories: work demands, work support (i.e., supervisory support), work-to-family conflict and its outcomes (i.e., life and job satisfaction). The structural equation modeling results showed that work overload and irregular work schedules were the significant predictors of work-to-family conflict and that work-to-family conflict was associated with lower job and life satisfaction. Moderated multiple regression analyses showed that social support from the supervisor did not moderate the relationships among work demands, work-to-family conflict, and satisfaction with job and life. Exploratory

  5. Continuous recording of pulmonary artery pressure in unrestricted subjects.

    PubMed Central

    Ikram, H; Richards, A M; Hamilton, E J; Nicholls, M G

    1984-01-01

    Continuous ambulatory pulmonary artery pressures were recorded using a conventional No 5 French Goodale-Lubin filled catheter linked to the Oxford Medilog system of a portable transducer-perfusion unit and miniaturised recorder. Data retrieval and analysis were performed using a PB2 Medilog playback unit linked to a PDP 11 computer system. The total system has a frequency response linear to 8 Hz allowing accurate pressure recording over the full range of heart rates. Ten recordings in 10 patients yielded artefact free data for 80% or more of the recorded period. This inexpensive reliable method allows pulmonary artery pressures to be recorded in unrestricted subjects. Images PMID:6704262

  6. Life style as a blood pressure determinant.

    PubMed

    Staessen, J A; Bieniaszewski, L; Pardaens, K; Petrov, V; Thijs, L; Fagard, R

    1996-09-01

    In Belgium, an affluent Western European country, participation in sports, alcohol intake, and living in a working class area were identified as the life style factors with the closest associations with the blood pressure level. Obesity was another important blood pressure correlate. Sodium intake, determined from the 24 h urinary output, and smoking were not associated with blood pressure. Controlled intervention studies have proven that weight reduction, endurance training and alcohol abstinence effectively reduce blood pressure. In the light of these intervention studies, the Belgian findings and the published work highlight the potential of preventive strategies aimed at these major life style factors.

  7. Measuring Pressure Has a New Standard

    NASA Technical Reports Server (NTRS)

    2002-01-01

    The Force-Balanced Piston Gauge (FPG) tests and calibrates instrumentation operating in the low pressure range. The system provides a traceable, primary calibration standard for measuring pressures in the range of near 0 to 15 kPa (2.2 psi) in both gauge and absolute measurement modes. The hardware combines a large area piston-cylinder with a load cell measuring the force resulting from pressures across the piston. The mass of the piston can be tared out, allowing measurement to start from zero. A pressure higher than the measured pressure, which keeps the piston centered, lubricates an innovative conical gap located between the piston and the cylinder, eliminating the need for piston rotation. A pressure controller based on the control of low gas flow automates the pressure control. DHI markets the FPG as an automated primary standard for very low-gauge and absolute pressures. DHI is selling the FPG to high-end metrology laboratories on a case by case basis, with a full commercial release to follow.

  8. Osmolyte depletion viewed in terms of the dividing membrane and its work of expansion against osmotic pressure.

    PubMed

    Shimizu, Seishi; Matubayasi, Nobuyuki

    2017-12-01

    How osmolytes enhance the folding, binding, and self-assembly of biological macromolecules at a microscopic scale has long been a matter of debate. Ambiguities persist on the key interpretive concepts, such as the "effective membrane" (which marks the boundary of the volume from which osmolytes are excluded) and the "free energy of exclusion" of osmolytes from biomolecular surfaces. In this paper, we formulate these elusive concepts based upon chemical thermodynamics and rigorous statistical thermodynamics (the Kirkwood-Buff theory). Positioning of the membrane at the osmotic dividing surface is crucial in order not to affect the thermodynamics of solvation. The notion of the free energy (work) of excluding osmolytes is refined to the expansion work against the osmotic pressure, which indeed describes the change of solvation free energy at dilute osmolyte concentrations. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. A Flexible Sensor Technology for the Distributed Measurement of Interaction Pressure

    PubMed Central

    Donati, Marco; Vitiello, Nicola; De Rossi, Stefano Marco Maria; Lenzi, Tommaso; Crea, Simona; Persichetti, Alessandro; Giovacchini, Francesco; Koopman, Bram; Podobnik, Janez; Munih, Marko; Carrozza, Maria Chiara

    2013-01-01

    We present a sensor technology for the measure of the physical human-robot interaction pressure developed in the last years at Scuola Superiore Sant'Anna. The system is composed of flexible matrices of opto-electronic sensors covered by a soft silicone cover. This sensory system is completely modular and scalable, allowing one to cover areas of any sizes and shapes, and to measure different pressure ranges. In this work we present the main application areas for this technology. A first generation of the system was used to monitor human-robot interaction in upper- (NEUROExos; Scuola Superiore Sant'Anna) and lower-limb (LOPES; University of Twente) exoskeletons for rehabilitation. A second generation, with increased resolution and wireless connection, was used to develop a pressure-sensitive foot insole and an improved human-robot interaction measurement systems. The experimental characterization of the latter system along with its validation on three healthy subjects is presented here for the first time. A perspective on future uses and development of the technology is finally drafted. PMID:23322104

  10. High-pressure oxidation of ethane

    DOE PAGES

    Hashemi, Hamid; Jacobsen, Jon G.; Rasmussen, Christian T.; ...

    2017-05-02

    Here, ethane oxidation at intermediate temperatures and high pressures has been investigated in both a laminar flow reactor and a rapid compression machine (RCM). The flow-reactor measurements at 600–900 K and 20–100 bar showed an onset temperature for oxidation of ethane between 700 and 825 K, depending on pressure, stoichiometry, and residence time. Measured ignition delay times in the RCM at pressures of 10–80 bar and temperatures of 900–1025 K decreased with increasing pressure and/or temperature. A detailed chemical kinetic model was developed with particular attention to the peroxide chemistry. Rate constants for reactions on the C 2H 5O 2more » potential energy surface were adopted from the recent theoretical work of Klippenstein. In the present work, the internal H-abstraction in CH 3CH 2OO to form CH 2CH 2OOH was treated in detail. Modeling predictions were in good agreement with data from the present work as well as results at elevated pressure from literature. The experimental results and the modeling predictions do not support occurrence of NTC behavior in ethane oxidation. Even at the high-pressure conditions of the present work where the C 2H 5 + O 2 reaction yields ethylperoxyl rather than C 2H 4 + HO 2, the chain branching sequence CH 3CH 2OO → CH 2CH 2OOH → +O2 OOCH 2CH 2OOH → branching is not competitive, because the internal H-atom transfer in CH 3CH 2OO to CH 2CH 2OOH is too slow compared to thermal dissociation to C 2H 4 and HO 2.« less

  11. 49 CFR 192.328 - Additional construction requirements for steel pipe using alternative maximum allowable operating...

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 3 2012-10-01 2012-10-01 false Additional construction requirements for steel pipe using alternative maximum allowable operating pressure. 192.328 Section 192.328 Transportation... Lines and Mains § 192.328 Additional construction requirements for steel pipe using alternative maximum...

  12. 49 CFR 192.328 - Additional construction requirements for steel pipe using alternative maximum allowable operating...

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 3 2014-10-01 2014-10-01 false Additional construction requirements for steel pipe using alternative maximum allowable operating pressure. 192.328 Section 192.328 Transportation... Lines and Mains § 192.328 Additional construction requirements for steel pipe using alternative maximum...

  13. Joint reconstruction of the initial pressure and speed of sound distributions from combined photoacoustic and ultrasound tomography measurements

    NASA Astrophysics Data System (ADS)

    Matthews, Thomas P.; Anastasio, Mark A.

    2017-12-01

    The initial pressure and speed of sound (SOS) distributions cannot both be stably recovered from photoacoustic computed tomography (PACT) measurements alone. Adjunct ultrasound computed tomography (USCT) measurements can be employed to estimate the SOS distribution. Under the conventional image reconstruction approach for combined PACT/USCT systems, the SOS is estimated from the USCT measurements alone and the initial pressure is estimated from the PACT measurements by use of the previously estimated SOS. This approach ignores the acoustic information in the PACT measurements and may require many USCT measurements to accurately reconstruct the SOS. In this work, a joint reconstruction method where the SOS and initial pressure distributions are simultaneously estimated from combined PACT/USCT measurements is proposed. This approach allows accurate estimation of both the initial pressure distribution and the SOS distribution while requiring few USCT measurements.

  14. Anchoring of development workings in a zone of influence of mining in case of the level anchoring system

    NASA Astrophysics Data System (ADS)

    Demin, V. F.; Fofanov, O. B.; Demina, T. V.; Yavorskiy, V. V.

    2017-02-01

    Regularities of the change of the stress-strain state of coal containing rock masses, depending on mining-geological factors, were revealed. These factors allow establishing rational parameters of anchoring of wall rocks to enhance the stability of development workings. Specific conditions of the deflected mode, displays of rock pressure, terms of maintenance depending on technological parameters are investigated. Researches allowed determining the degree of their development influence on the efficiency of application of the anchoring of the hollow making and will allow a reasonable application of anchoring certificates, provide stability of the rocks mining and reduce expenses on its realization and maintenance.

  15. Simple telemetering system for signaling high rumen pressures.

    PubMed

    PAYNE, L C

    1960-02-26

    The construction of a modified Hartley oscillator transmitter activated through a pressure switch is described. When this device is placed within the rumen of a cow which is allowed unrestricted movement in the pasture, frequency-modulation signals are transmitted to a recording receiver whenever a preselected pressure is exceeded. The pressure at which transmission begins is determined by the capacitance across the coil of the circuit.

  16. Advanced Pressure Coring System for Deep Earth Sampling (APRECOS)

    NASA Astrophysics Data System (ADS)

    Anders, E.; Rothfuss, M.; Müller, W. H.

    2009-04-01

    Nowadays the recovery of cores from boreholes is a standard operation. However, during that process the mechanical, physical, and chemical properties as well as living conditions for microorganisms are significantly altered. In-situ sampling is one approach to overcome the severe scientific limitations of conventional, depressurized core investigations by recovering, processing, and conducting experiments in the laboratory, while maintaining unchanged environmental parameters. The most successful equipment today is the suite of tools developed within the EU funded projects HYACE (Hydrate Autoclave Coring Equipment) and HYACINTH (Deployment of HYACE tools In New Tests on Hydrates) between 1997 and 2005. Within several DFG (German Research Foundation) projects the Technical University Berlin currently works on concepts to increase the present working pressure of 250 bar as well as to reduce logistical and financial expenses by merging redundant and analogous procedures and scaling down the considerable size of key components. It is also proposed to extend the range of applications for the wireline rotary pressure corer and the sub-sampling and transfer system to all types of soil conditions (soft to highly-consolidated). New modifications enable the tools to be used in other pressure related fields of research, such as unconventional gas exploration (coal-bed methane, tight gas, gas hydrate), CO2 sequestration, and microbiology of the deep biosphere. Expedient enhancement of an overall solution for pressure core retrieval, process and investigation will open the way for a complete on-site, all-purpose, in-situ equipment. The advanced assembly would allow for executing the whole operation sequences of coring, non-destructive measurement, sub-sampling and transfer into storage, measurement and transportation chambers, all in sterile, anaerobic conditions, and without depressurisation in quick succession. Extensive post-cruise handling and interim storage would be

  17. A simplified model for the determination of current-voltage characteristics of a high pressure hydrogen plasma arc

    NASA Astrophysics Data System (ADS)

    Gueye, P.; Cressault, Y.; Rohani, V.; Fulcheri, L.

    2017-02-01

    This paper focuses on the modeling of a hydrogen arc column at very high pressure (20 bar). The problem is solved from Elenbaas-Heller equation where the radiation is carefully considered with the net emission coefficient. The absorption spectrum requires the integration of background continuum, molecular bands, and line spectra. This work directly aims to predict the electric current-voltage characteristics which is key for the design of new processes. We propose also a new analytic solution which generalizes the channel model of electric arc to the case when the volume radiation makes a significant contribution to the energy balance. The presented formalism allows a better determination of the plasma thickness parameter Rp for net emission coefficient method in cylindrical arcs and gives satisfactory results in comparison to earlier experimental works on high pressure hydrogen plasma.

  18. Controlling and assessing pressure conditions during treatment of tar sands formations

    DOEpatents

    Zhang, Etuan; Beer, Gary Lee

    2015-11-10

    A method for treating a tar sands formation includes providing heat to at least part of a hydrocarbon layer in the tar sands formation from a plurality of heaters located in the formation. Heat is allowed to transfer from the heaters to at least a portion of the formation. A pressure in the portion of the formation is controlled such that the pressure remains below a fracture pressure of the formation overburden while allowing the portion of the formation to heat to a selected average temperature of at least about 280.degree. C. and at most about 300.degree. C. The pressure in the portion of the formation is reduced to a selected pressure after the portion of the formation reaches the selected average temperature.

  19. NMR at pressures up to 90 GPa

    NASA Astrophysics Data System (ADS)

    Meier, Thomas; Khandarkhaeva, Saiana; Petitgirard, Sylvain; Körber, Thomas; Lauerer, Alexander; Rössler, Ernst; Dubrovinsky, Leonid

    2018-07-01

    The past 15 years have seen an astonishing increase in Nuclear Magnetic Resonance (NMR) sensitivity and accessible pressure range in high-pressure NMR experiments, owing to a series of new developments of NMR spectroscopy applied to the diamond anvil cell (DAC). Recently, with the application of electro-magnetic lenses, so-called Lenz lenses, in toroidal diamond indenter cells, pressures of up to 72 GPa with NMR spin sensitivities of about 1012 spin/Hz1/2 has been achieved. Here, we describe the implementation of a refined NMR resonator structure using a pair of double stage Lenz lenses driven by a Helmholtz coil within a standard DAC, allowing to measure sample volumes as small as 100 pl prior to compression. With this set-up, pressures close to 100 GPa could be realised repeatedly, with enhanced spin sensitivities of about 5 × 1011 spin/Hz1/2. The manufacturing and handling of these new NMR-DACs is relatively easy and straightforward, which will allow for further applications in physics, chemistry, or biochemistry.

  20. A Study of the Job Satisfaction of Professional Air Force Social Work Officers.

    DTIC Science & Technology

    1984-01-01

    organizational) system’s environment (if so defined by legitimate authori- ties)." (Bachman et al., 1977:106-107) This belief system is fostered by a number... foster an impersonality which social work can find compatible with its norm of regarding the client with a certain detachment which allows the social... foster competing interests and conflicts. Military organizations share in these job pressures. This may limit the degree to which any military organization

  1. Yeast and mammalian metabolism continuous monitoring by using pressure recording as an assessment technique for xenobiotic agent effects

    NASA Astrophysics Data System (ADS)

    Milani, Marziale; Ballerini, Monica; Ferraro, Lorenzo; Marelli, E.; Mazza, Francesca; Zabeo, Matteo

    2002-06-01

    Our work is devoted to the study of Saccharomyces cerevisiae and human lymphocytes cellular metabolism in order to develop a reference model to assess biological systems responses to chemical or physical agents exposure. CO2 variations inside test-tubes are measured by differential pressure sensors; pressure values are subsequently converted in voltage. The system allows to test up to 16 samples at the same time. Sampling manages up to 100 acquisitions per second. Values are recorded by a data acquisition card connected to a computer. This procedure leads to a standard curve (pressure variation versus time), typical of the cellular line, that describe cellular metabolism. The longest time lapse used is of 170 h. Different phases appear in this curve: an initial growth up to a maximum, followed by a decrement that leads to a typical depression (pressure value inside the test-tubes is lower than the initial one) after about 35 h from the beginning of yeast cells. The curve is reproducible within an experimental error of 4%. The analysis of many samples and the low cost of the devices allow a good statistical significance of the data. In particular as a test we will compare two sterilizing agents effects: UV radiation and amuchina.

  2. Design and Development of a Pressure Transducer for High Hydrostatic Pressure Measurements up to 200 MPa

    NASA Astrophysics Data System (ADS)

    Kumar, Anuj; Yadav, Sanjay; Agarwal, Ravinder

    2017-08-01

    A number of pressure transducers, based on strain gauge, capacitance/inductance type, frequency resonators, are commercially available and are being used for sensing and producing an electrical output proportional to applied pressure. These sensors have their own advantages and limitations due to operational ease, measurement uncertainty and the costs. Strain gauge type transducers are now well established devices for accurate and precise measurement of pressure within measurement uncertainty up to 0.1 % of full scale. In the present research work, an indigenous strain gauge pressure transducer has been designed, developed, tested and calibrated for pressure measurement up to 200 MPa. The measurement uncertainty estimated using the pressure transducer was found better than 0.1 % of full scale. This transducer was developed using four foil type strain gauges, bonded, two in axial direction while other two in radial direction, to the controlled stress zones of a tubular maraging steel active cylinder working also as diaphragm. The strain gages were then connected to a Wheatstone bridge arrangement to measure stress generated strains. The pressure was applied through matching connector designed in the same tubular transducer active element. The threaded unique design in a single piece through collar, ferule and tubing arrangement provides leak proof pressure connections with external devices without using additional seals. The calibration and performance checking of the pressure transducer was carried out using dead weight type national pressure standard using the internationally accepted calibration procedure.

  3. Pressure redistribution devices: what works, at what cost and what's next?

    PubMed

    Clancy, Michael J

    2013-08-01

    This article discusses the development and usage of pressure redistribution devices (PRDs) and their impact on the prevention and treatment of pressure ulcers within the NHS. The article outlines the history of the development of these devices and discusses the reasons for a lack of substantial evidence in support of the use of these devices, their impact on the NHS on cost and perceived outcome. The article describes the typical usage profile in a 500 bed NHS hospital and concludes with a view as to how that may change in the future. Copyright © 2013 Tissue Viability Society. Published by Elsevier Ltd. All rights reserved.

  4. High pressure metrology for industrial applications

    NASA Astrophysics Data System (ADS)

    Sabuga, Wladimir; Rabault, Thierry; Wüthrich, Christian; Pražák, Dominik; Chytil, Miroslav; Brouwer, Ludwig; Ahmed, Ahmed D. S.

    2017-12-01

    To meet the needs of industries using high pressure technologies, in traceable, reliable and accurate pressure measurements, a joint research project of the five national metrology institutes and the university was carried out within the European Metrology Research Programme. In particular, finite element methods were established for stress-strain analysis of elastic and nonlinear elastic-plastic deformation, as well as of contact processes in pressure-measuring piston-cylinder assemblies, and high-pressure components at pressures above 1 GPa. New pressure measuring multipliers were developed and characterised, which allow realisation of the pressure scale up to 1.6 GPa. This characterisation is based on research including measurements of material elastic constants by the resonant ultrasound spectroscopy, hardness of materials of high pressure components, density and viscosity of pressure transmitting liquids at pressures up to 1.4 GPa and dimensional measurements on piston-cylinders. A 1.6 GPa pressure system was created for operation of the 1.6 GPa multipliers and calibration of high pressure transducers. A transfer standard for 1.5 GPa pressure range, based on pressure transducers, was built and tested. Herewith, the project developed the capability of measuring pressures up to 1.6 GPa, from which industrial users can calibrate their pressure measurement devices for accurate measurements up to 1.5 GPa.

  5. Reduced pressure for fewer pressure ulcers: can real-time feedback of interface pressure optimise repositioning in bed?

    PubMed

    Gunningberg, Lena; Carli, Cheryl

    2016-10-01

    The aim of this study was to (i) describe registered nurses' and assistant nurses' repositioning skills with regard to their existing attitudes to and theoretical knowledge of pressure ulcer (PU) prevention, and (ii) evaluate if the continuous bedside pressure mapping (CBPM) system provides staff with a pedagogic tool to optimise repositioning. A quantitative study was performed using a descriptive, comparative design. Registered nurses (n = 19) and assistant nurses (n = 33) worked in pairs, and were instructed to place two volunteers (aged over 70 years) in the best pressure-reducing position (lateral and supine), first without viewing the CBPM monitor and then again after feedback. In total, 240 positionings were conducted. The results show that for the same person with the same available pressure-reducing equipment, the peak pressure varied considerably between nursing pairs. Reducing pressure in the lateral position appeared to be the most challenging. Peak pressures were significantly reduced, based on visual feedback from the CBPM monitor. The number of preventive interventions also increased, as well as patients' comfort. For the nurses as a group, the knowledge score was 59·7% and the attitude score was 88·8%. Real-time visual feedback of pressure points appears to provide another dimension to complement decision making with respect to PU prevention. © 2014 The Authors. International Wound Journal © 2014 Medicalhelplines.com Inc and John Wiley & Sons Ltd.

  6. Self-Calibrating Pressure Transducer

    NASA Technical Reports Server (NTRS)

    Lueck, Dale E. (Inventor)

    2006-01-01

    A self-calibrating pressure transducer is disclosed. The device uses an embedded zirconia membrane which pumps a determined quantity of oxygen into the device. The associated pressure can be determined, and thus, the transducer pressure readings can be calibrated. The zirconia membrane obtains oxygen .from the surrounding environment when possible. Otherwise, an oxygen reservoir or other source is utilized. In another embodiment, a reversible fuel cell assembly is used to pump oxygen and hydrogen into the system. Since a known amount of gas is pumped across the cell, the pressure produced can be determined, and thus, the device can be calibrated. An isolation valve system is used to allow the device to be calibrated in situ. Calibration is optionally automated so that calibration can be continuously monitored. The device is preferably a fully integrated MEMS device. Since the device can be calibrated without removing it from the process, reductions in costs and down time are realized.

  7. Flexible Polydimethylsiloxane Foams Decorated with Multiwalled Carbon Nanotubes Enable Unprecedented Detection of Ultralow Strain and Pressure Coupled with a Large Working Range.

    PubMed

    Iglio, Rossella; Mariani, Stefano; Robbiano, Valentina; Strambini, Lucanos; Barillaro, Giuseppe

    2018-04-25

    Low-cost piezoresistive strain/pressure sensors with large working range, at the same time able to reliably detect ultralow strain (≤0.1%) and pressure (≤1 Pa), are one of the challenges that have still to be overcome for flexible piezoresistive materials toward personalized health-monitoring applications. In this work, we report on unprecedented, simultaneous detection of ultrasmall strain (0.1%, i.e., 10 μm displacement over 10 mm) and subtle pressure (20 Pa, i.e., a force of only 2 mN over an area of 1 cm 2 ) in compression mode, coupled with a large working range (i.e., up to 60% for strain-6 mm in displacement-and 50 kPa for pressure) using piezoresistive, flexible three-dimensional (3D) macroporous polydimethylsiloxane (pPDMS) foams decorated with pristine multiwalled carbon nanotubes (CNTs). pPDMS/CNT foams with pore size up to 500 μm (i.e., twice the size of those of commonly used foams, at least) and porosity of 77%, decorated with a nanostructured surface network of CNTs at densities ranging from 7.5 to 37 mg/cm 3 are prepared using a low-cost and scalable process, through replica molding of sacrificial sugar templates and subsequent drop-casting of CNT ink. A thorough characterization shows that piezoresistive properties of the foams can be finely tuned by controlling the CNT density and reach an optimum at a CNT density of 25 mg/cm 3 , for which a maximum change of the material resistivity (e.g., ρ 0 /ρ 50 = 4 at 50% strain) is achieved under compression. Further static and dynamic characterization of the pPDMS/CNT foams with 25 mg/cm 3 of CNTs highlights that detection limits for strain and pressure are 0.03% (3 μm displacement over 10 mm) and 6 Pa (0.6 mN over an area of 1 cm 2 ), respectively; moreover, good stability and limited hysteresis are apparent by cycling the foams with 255 compression-release cycles over the strain range of 0-60%, at different strain rates up to 10 mm/min. Our results on piezoresistive, flexible pPDMS/CNT foams

  8. High pressure xenon ionization detector

    DOEpatents

    Markey, J.K.

    1989-11-14

    A method is provided for detecting ionization comprising allowing particles that cause ionization to contact high pressure xenon maintained at or near its critical point and measuring the amount of ionization. An apparatus is provided for detecting ionization, the apparatus comprising a vessel containing a ionizable medium, the vessel having an inlet to allow high pressure ionizable medium to enter the vessel, a means to permit particles that cause ionization of the medium to enter the vessel, an anode, a cathode, a grid and a plurality of annular field shaping rings, the field shaping rings being electrically isolated from one another, the anode, cathode, grid and field shaping rings being electrically isolated from one another in order to form an electric field between the cathode and the anode, the electric field originating at the anode and terminating at the cathode, the grid being disposed between the cathode and the anode, the field shaping rings being disposed between the cathode and the grid, the improvement comprising the medium being xenon and the vessel being maintained at a pressure of 50 to 70 atmospheres and a temperature of 0 to 30 C. 2 figs.

  9. High pressure xenon ionization detector

    DOEpatents

    Markey, John K.

    1989-01-01

    A method is provided for detecting ionization comprising allowing particles that cause ionization to contact high pressure xenon maintained at or near its critical point and measuring the amount of ionization. An apparatus is provided for detecting ionization, the apparatus comprising a vessel containing a ionizable medium, the vessel having an inlet to allow high pressure ionizable medium to enter the vessel, a means to permit particles that cause ionization of the medium to enter the vessel, an anode, a cathode, a grid and a plurality of annular field shaping rings, the field shaping rings being electrically isolated from one another, the anode, cathode, grid and field shaping rings being electrically isolated from one another in order to form an electric field between the cathode and the anode, the electric field originating at the anode and terminating at the cathode, the grid being disposed between the cathode and the anode, the field shaping rings being disposed between the cathode and the grid, the improvement comprising the medium being xenon and the vessel being maintained at a pressure of 50 to 70 atmospheres and a temperature of 0.degree. to 30.degree. C.

  10. Pressure Variations in Metamorphic Rocks: Implications for the Interpretation of Petrographic Observations

    NASA Astrophysics Data System (ADS)

    Tajčmanová, Lucie

    2014-05-01

    Metamorphic petrologists and structural geologists, using direct measurements, bring the only direct observational constrains for validating geodynamic models. Therefore, petrological and structural geological observations are essential for the quality and reproducibility of geodynamic reconstructions and models. One of the important assumptions for geodynamic reconstructions arises from the pressure and temperature estimates in the petrology analysis. Pressure is commonly converted to depth through the equation for lithostatic pressure and so the original position of the rock sample within the Earth's interior can be constrained. The current assumption that the studied sample corresponds to uniform pressure may not be correct, and if so, it has serious implications. Increasing evidence from analytical data shows that pressure is not constant even on a grain scale, posing new challenges because, if ignored, it leads to an incorrect use of petrology data in constraining geodynamic models. Well known examples of the preservation of coesite and diamond in a host mineral like garnet show that high pressure inclusions are preserved during decompression. Tajčmanová et al. (2014) has shown that grain-scale pressure variations can develop and that these pressure variations allow compositional zoning in minerals preserved over geological time scales. A new unconventional barometric method based on equilibrium under pressure variations has been developed . Such pressure variations are also connected with differences in fluid pressure in open systems and can be thus observed at all scales. Tajčmanová L., Podladchikov Y., Powell R., Moulas E., Vrijmoed J. and Connolly J. (2014). Grain scale pressure variations and chemical equilibrium in high-grade metamorphic rocks.Journal of Metamorphic Geology, doi:10.1111/jmg.12066 This work was supported by ERC starting grant 335577 to Lucie Tajcmanova

  11. HIGH PRESSURE GAS REGULATOR

    DOEpatents

    Ramage, R.W.

    1962-05-01

    A gas regulator operating on the piston and feedback principle is described. The device is particularly suitable for the delicate regulation of high pressure, i.e., 10,000 psi and above, gas sources, as well as being perfectly adaptable for use on gas supplies as low as 50 psi. The piston is adjustably connected to a needle valve and the movement of the piston regulates the flow of gas from the needle valve. The gas output is obtained from the needle valve. Output pressure is sampled by a piston feedback means which, in turn, regulates the movement of the main piston. When the output is other than the desired value, the feedback system initiates movement of the main piston to allow the output pressure to be corrected or to remain constant. (AEC)

  12. Calibration improvements to electronically scanned pressure systems and preliminary statistical assessment

    NASA Technical Reports Server (NTRS)

    Everhart, Joel L.

    1996-01-01

    Orifice-to-orifice inconsistencies in data acquired with an electronically-scanned pressure system at the beginning of a wind tunnel experiment forced modifications to the standard, instrument calibration procedures. These modifications included a large increase in the number of calibration points which would allow a critical examination of the calibration curve-fit process, and a subsequent post-test reduction of the pressure data. Evaluation of these data has resulted in an improved functional representation of the pressure-voltage signature for electronically-scanned pressures sensors, which can reduce the errors due to calibration curve fit to under 0.10 percent of reading compared to the manufacturer specified 0.10 percent of full scale. Application of the improved calibration function allows a more rational selection of the calibration set-point pressures. These pressures should be adjusted to achieve a voltage output which matches the physical shape of the pressure-voltage signature of the sensor. This process is conducted in lieu of the more traditional approach where a calibration pressure is specified and the resulting sensor voltage is recorded. The fifteen calibrations acquired over the two-week duration of the wind tunnel test were further used to perform a preliminary, statistical assessment of the variation in the calibration process. The results allowed the estimation of the bias uncertainty for a single instrument calibration; and, they form the precursor for more extensive and more controlled studies in the laboratory.

  13. Soft x-ray spectroscopy of high pressure liquid.

    PubMed

    Qiao, Ruimin; Xia, Yujian; Feng, Xuefei; Macdougall, James; Pepper, John; Armitage, Kevin; Borsos, Jason; Knauss, Kevin G; Lee, Namhey; Allézy, Arnaud; Gilbert, Benjamin; MacDowell, Alastair A; Liu, Yi-Sheng; Glans, Per-Anders; Sun, Xuhui; Chao, Weilun; Guo, Jinghua

    2018-01-01

    We describe a new experimental technique that allows for soft x-ray spectroscopy studies (∼100-1000 eV) of high pressure liquid (∼100 bars). We achieve this through a liquid cell with a 100 nm-thick Si 3 N 4 membrane window, which is sandwiched by two identical O-rings for vacuum sealing. The thin Si 3 N 4 membrane allows soft x-rays to penetrate, while separating the high-pressure liquid under investigation from the vacuum required for soft x-ray transmission and detection. The burst pressure of the Si 3 N 4 membrane increases with decreasing size and more specifically is inversely proportional to the side length of the square window. It also increases proportionally with the membrane thickness. Pressures > 60 bars could be achieved for 100 nm-thick square Si 3 N 4 windows that are smaller than 65 μm. However, above a certain pressure, the failure of the Si wafer becomes the limiting factor. The failure pressure of the Si wafer is sensitive to the wafer thickness. Moreover, the deformation of the Si 3 N 4 membrane is quantified using vertical scanning interferometry. As an example of the performance of the high-pressure liquid cell optimized for total-fluorescence detected soft x-ray absorption spectroscopy (sXAS), the sXAS spectra at the Ca L edge (∼350 eV) of a CaCl 2 aqueous solution are collected under different pressures up to 41 bars.

  14. Soft x-ray spectroscopy of high pressure liquid

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Qiao, Ruimin; Xia, Yujian; Feng, Xuefei

    Here, we describe a new experimental technique that allows for soft x-ray spectroscopy studies (~100-1000 eV) of high pressure liquid (~100 bars). We achieve this through a liquid cell with a 100 nm-thick Si 3N 4 membrane window, which is sandwiched by two identical O-rings for vacuum sealing. The thin Si 3N 4 membrane allows soft x-rays to penetrate, while separating the high-pressure liquid under investigation from the vacuum required for soft x-ray transmission and detection. The burst pressure of the Si 3N 4 membrane increases with decreasing size and more specifically is inversely proportional to the side length ofmore » the square window. It also increases proportionally with the membrane thickness. Pressures > 60 bars could be achieved for 100 nm-thick square Si 3N 4 windows that are smaller than 65 μm. However, above a certain pressure, the failure of the Si wafer becomes the limiting factor. The failure pressure of the Si wafer is sensitive to the wafer thickness. Moreover, the deformation of the Si 3N 4 membrane is quantified using vertical scanning interferometry. As an example of the performance of the high-pressure liquid cell optimized for total-fluorescence detected soft x-ray absorption spectroscopy (sXAS), the sXAS spectra at the Ca L edge (~350 eV) of a CaCl 2 aqueous solution are collected under different pressures up to 41 bars.« less

  15. Soft x-ray spectroscopy of high pressure liquid

    DOE PAGES

    Qiao, Ruimin; Xia, Yujian; Feng, Xuefei; ...

    2018-01-01

    Here, we describe a new experimental technique that allows for soft x-ray spectroscopy studies (~100-1000 eV) of high pressure liquid (~100 bars). We achieve this through a liquid cell with a 100 nm-thick Si 3N 4 membrane window, which is sandwiched by two identical O-rings for vacuum sealing. The thin Si 3N 4 membrane allows soft x-rays to penetrate, while separating the high-pressure liquid under investigation from the vacuum required for soft x-ray transmission and detection. The burst pressure of the Si 3N 4 membrane increases with decreasing size and more specifically is inversely proportional to the side length ofmore » the square window. It also increases proportionally with the membrane thickness. Pressures > 60 bars could be achieved for 100 nm-thick square Si 3N 4 windows that are smaller than 65 μm. However, above a certain pressure, the failure of the Si wafer becomes the limiting factor. The failure pressure of the Si wafer is sensitive to the wafer thickness. Moreover, the deformation of the Si 3N 4 membrane is quantified using vertical scanning interferometry. As an example of the performance of the high-pressure liquid cell optimized for total-fluorescence detected soft x-ray absorption spectroscopy (sXAS), the sXAS spectra at the Ca L edge (~350 eV) of a CaCl 2 aqueous solution are collected under different pressures up to 41 bars.« less

  16. Deployment of a Pressure Sensitive Paint System for Measuring Global Surface Pressures on Rotorcraft Blades in Simulated Forward Flight

    NASA Technical Reports Server (NTRS)

    Watkins, A. Neal; Leighty, Bradley; Lipford, William E.; Wong, Oliver D.; Goodman, Kyle Z.; Crafton, Jim; Forlines, Alan; Goss, Larry P.; Gregory, James W.; Juliano, Thomas J.

    2012-01-01

    This paper will present details of a Pressure Sensitive Paint (PSP) system for measuring global surface pressures on the tips of rotorcraft blades in simulated forward flight at the 14- x 22-Foot Subsonic Tunnel at the NASA Langley Research Center. The system was designed to use a pulsed laser as an excitation source and PSP data was collected using the lifetime-based approach. With the higher intensity of the laser, this allowed PSP images to be acquired during a single laser pulse, resulting in the collection of crisp images that can be used to determine blade pressure at a specific instant in time. This is extremely important in rotorcraft applications as the blades experience dramatically different flow fields depending on their position in the rotor disk. Testing of the system was performed using the U.S. Army General Rotor Model System equipped with four identical blades. Two of the blades were instrumented with pressure transducers to allow for comparison of the results obtained from the PSP. Preliminary results show that the PSP agrees both qualitatively and quantitatively with both the expected results as well as with the pressure taps. Several areas of improvement have been indentified and are currently being developed.

  17. Pressure Self-focusing Effect and Novel Methods for Increasing the Maximum Pressure in Traditional and Rotational Diamond Anvil Cells.

    PubMed

    Feng, Biao; Levitas, Valery I

    2017-04-21

    The main principles of producing a region near the center of a sample, compressed in a diamond anvil cell (DAC), with a very high pressure gradient and, consequently, with high pressure are predicted theoretically. The revealed phenomenon of generating extremely high pressure gradient is called the pressure self-focusing effect. Initial analytical predictions utilized generalization of a simplified equilibrium equation. Then, the results are refined using our recent advanced model for elastoplastic material under high pressures in finite element method (FEM) simulations. The main points in producing the pressure self-focusing effect are to use beveled anvils and reach a very thin sample thickness at the center. We find that the superposition of torsion in a rotational DAC (RDAC) offers drastic enhancement of the pressure self-focusing effect and allows one to reach the same pressure under a much lower force and deformation of anvils.

  18. Improving of the working process of axial compressors of gas turbine engines by using an optimization method

    NASA Astrophysics Data System (ADS)

    Marchukov, E.; Egorov, I.; Popov, G.; Baturin, O.; Goriachkin, E.; Novikova, Y.; Kolmakova, D.

    2017-08-01

    The article presents one optimization method for improving of the working process of an axial compressor of gas turbine engine. Developed method allows to perform search for the best geometry of compressor blades automatically by using optimization software IOSO and CFD software NUMECA Fine/Turbo. Optimization was performed by changing the form of the middle line in the three sections of each blade and shifts of three sections of the guide vanes in the circumferential and axial directions. The calculation of the compressor parameters was performed for work and stall point of its performance map on each optimization step. Study was carried out for seven-stage high-pressure compressor and three-stage low-pressure compressors. As a result of optimization, improvement of efficiency was achieved for all investigated compressors.

  19. Job strain, blood pressure and response to uncontrollable stress.

    PubMed

    Steptoe, A; Cropley, M; Joekes, K

    1999-02-01

    The association between cardiovascular disease risk and job strain (high-demand, low-control work) may be mediated by heightened physiological stress responsivity. We hypothesized that high levels of job strain lead to increased cardiovascular responses to uncontrollable but not controllable stressors. Associations between job strain and blood pressure reductions after the working day (unwinding) were also assessed. Assessment of cardiovascular responses to standardized behavioral tasks, and ambulatory monitoring of blood pressure and heart rate during a working day and evening. We studied 162 school teachers (60 men, 102 women) selected from a larger survey as experiencing high or low job strain. Blood pressure, heart rate and electrodermal responses to an externally paced (uncontrollable) task and a self-paced (controllable) task were assessed. Blood pressure was monitored using ambulatory apparatus from 0900 to 2230 h on a working day. The groups of subjects with high and low job strain did not differ in demographic factors, body mass or resting cardiovascular activity. Blood pressure reactions to the uncontrollable task were greater in high than low job-strain groups, but responses to the controllable task were not significantly different between groups. Systolic and diastolic blood pressure did not differ between groups over the working day, but decreased to a greater extent in the evening in subjects with low job strain. Job strain is associated with a heightened blood pressure response to uncontrollable but not controllable tasks. The failure of subjects with high job strain to show reduced blood pressure in the evening may be a manifestation of chronic allostatic load.

  20. Beat-to-Beat Blood Pressure Monitor

    NASA Technical Reports Server (NTRS)

    Lee, Yong Jin

    2012-01-01

    This device provides non-invasive beat-to-beat blood pressure measurements and can be worn over the upper arm for prolonged durations. Phase and waveform analyses are performed on filtered proximal and distal photoplethysmographic (PPG) waveforms obtained from the brachial artery. The phase analysis is used primarily for the computation of the mean arterial pressure, while the waveform analysis is used primarily to obtain the pulse pressure. Real-time compliance estimate is used to refine both the mean arterial and pulse pressures to provide the beat-to-beat blood pressure measurement. This wearable physiological monitor can be used to continuously observe the beat-to-beat blood pressure (B3P). It can be used to monitor the effect of prolonged exposures to reduced gravitational environments and the effectiveness of various countermeasures. A number of researchers have used pulse wave velocity (PWV) of blood in the arteries to infer the beat-to-beat blood pressure. There has been documentation of relative success, but a device that is able to provide the required accuracy and repeatability has not yet been developed. It has been demonstrated that an accurate and repeatable blood pressure measurement can be obtained by measuring the phase change (e.g., phase velocity), amplitude change, and distortion of the PPG waveforms along the brachial artery. The approach is based on comparing the full PPG waveform between two points along the artery rather than measuring the time-of-flight. Minimizing the measurement separation and confining the measurement area to a single, well-defined artery allows the waveform to retain the general shape between the two measurement points. This allows signal processing of waveforms to determine the phase and amplitude changes. Photoplethysmography, which measures changes in arterial blood volume, is commonly used to obtain heart rate and blood oxygen saturation. The digitized PPG signals are used as inputs into the beat-to-beat blood

  1. FOREWORD: CCM Second International Seminar: Pressure Metrology from 1 kPa to 1 GPa

    NASA Astrophysics Data System (ADS)

    Molinar, G. F.

    1994-01-01

    , it was at a high level. This special issue of Metrologia brings together all the seminar papers accepted for publication after a careful review process controlled directly by the organizing committee of the seminar and the Metrologia editor. I feel that we have succeeded reasonably well. The papers published here focus on important achievements in pressure measurements and the main problems which the scientific community is working to resolve in the future. Various achievements are reported, ranging from a general improvement in accuracy to new devices and techniques. I would like to thank all those who helped with this seminar. First, the members of the organizing committee: Chairman of the CCM Medium Pressure Work ing Group, P Stuart, (NPL, UK); J Bonhoure (BIPM); V Borovkov (VNIIFTRI, Russia); C Ehrlich (NIST, USA); J Jager (PTB, Germany); J C Legras (LNE); Chairman of the CCM Low Pressure Working Group, C Tilford (NIST, USA); S Yamamoto (NRLM, Japan); R Wirniewski (WUT, Poland); not forgetting the institutions that allowed them to spend considerable time on the preparation and organization of the seminar. I extend my thanks to V E Bean (NIST, USA), A Ooiwa (NRLM, Japan), and A J Rostocki (WUT, Poland), who joined the organizing committee as guest editors and helped to see the papers presented at the seminar through the review process and into print. Many thanks are also due to A Bryden, Director of the Laboratoire National d'Essais, and to J C Legras of the LNE Pressure Laboratory, for hosting the seminar and for taking care of all practical problems. A special thanks to T J Quinn, Director of the Bureau International des Poids et Mesures, for his continuous support and encouragement in the preparation of the seminar. Grateful thanks to Desgranges et Huot, France, for their hospitality in Paris; and to D-H Instruments Co., USA, and Ruska Co., USA, which sponsored the seminar through their fmancial support for the publication of these Proceedings. A special

  2. Surface forces between colloidal particles at high hydrostatic pressure

    NASA Astrophysics Data System (ADS)

    Pilat, D. W.; Pouligny, B.; Best, A.; Nick, T. A.; Berger, R.; Butt, H.-J.

    2016-02-01

    It was recently suggested that the electrostatic double-layer force between colloidal particles might weaken at high hydrostatic pressure encountered, for example, in deep seas or during oil recovery. We have addressed this issue by means of a specially designed optical trapping setup that allowed us to explore the interaction of a micrometer-sized glass bead and a solid glass wall in water at hydrostatic pressures of up to 1 kbar. The setup allowed us to measure the distance between bead and wall with a subnanometer resolution. We have determined the Debye lengths in water for salt concentrations of 0.1 and 1 mM. We found that in the pressure range from 1 bar to 1 kbar the maximum variation of the Debye lengths was <1 nm for both salt concentrations. Furthermore, the magnitude of the zeta potentials of the glass surfaces in water showed no dependency on pressure.

  3. Seal for permitting transfer of tape from one pressure region to a region of substantially different pressure

    DOEpatents

    Carter, H. Kennon; Mlekodaj, Ronald L.

    1977-01-01

    A seal is provided for allowing a thin flexible tape to be pulled from a high vacuum region (less than 10.sup.-.sup.6 torr) into atmospheric pressure. The tape first passes through a slit in an elastomer and thence through a pool of vacuum pump fluid into a differentially pumped volume. A second slit in an elastomer is the final seal element prior to exit of the tape to atmospheric pressure. The vacuum seal is utilized in a system for the rapid removal of samples, implanted in the surface of the tape, from a vacuum system to atmospheric pressure.

  4. High-pressure portable pneumatic drive unit.

    PubMed

    Hete, B F; Savage, M; Batur, C; Smith, W A; Golding, L A; Nosé, Y

    1989-12-01

    The left ventricular assist device (LVAD) of the Cleveland Clinic Foundation (CCF) is a single-chamber assist pump, driven by a high-pressure pneumatic cylinder. A low-cost, portable driver that will allow cardiac care patients, with a high-pressure pneumatic ventricle assist, more freedom of movement has been developed. The compact and light-weight configuration can provide periods of 2 h of freedom from a fixed position driver and does not use exotic technology.

  5. Simulated Martian pressure cycle based on the sublimation and deposition of polar CO2

    NASA Astrophysics Data System (ADS)

    Kemppinen, Osku; Paton, Mark; Savijärvi, Hannu; Harri, Ari-Matti

    2014-05-01

    The Martian atmospheric pressure cycle is driven by sublimation and deposition of CO2 at polar caps. In the thin atmosphere of Mars the surface energy balance and thus the phase changes of CO2 are dominated by radiation. Additionally, because the atmosphere is so thin, the annual polar cap cycle can have a large relative effect on the pressure. In this work we utilize radiative transfer models to calculate the amount of radiation incoming to Martian polar latitudes over each sol of the year, as well as the amount of energy lost from the surface due to thermal radiation. The energy budget calculated in this way allows us to estimate the amount of CO2 sublimating and depositing at each hour of the Martian year. Since virtually all of the sublimated CO2 is believed to enter and stay in the atmosphere until depositing, this estimate allows us to calculate the annual pressure cycle, assuming that the CO2 is distributed approximately evenly over the planet. The model is running with physically plausible parameters and producing encouragingly good fits to in situ measured data made by e.g. Viking landers. In the next phase we will validate the simulation runs against polar ice cap thickness measurements as well as compare the calculated CO2 source and sink strengths to the sources and sinks of global atmospheric models.

  6. Pressure Effects on Oxygen Concentration Flammability Thresholds of Materials for Aerospace Applications

    NASA Technical Reports Server (NTRS)

    Hirsch, David; Williams, Jim; Beeson, Harold

    2006-01-01

    Spacecraft materials selection is based on an upward flammability test conducted in a quiescent environment in the highest-expected oxygen-concentration environment. However, NASA s advanced space exploration program is anticipating using various habitable environments. Because limited data is available to support current program requirements, a different test logic is suggested to address these expanded atmospheric environments through the determination of materials self-extinguishment limits. This paper provides additional pressure effects data on oxygen concentration and partial pressure self-extinguishment limits under quiescent conditions. For the range of total pressures tested, the oxygen concentration and oxygen partial pressure flammability thresholds show a near linear function of total pressure. The oxygen concentration/oxygen partial pressure flammability thresholds depend on the total pressure and appear to increase with increasing oxygen concentration (and oxygen partial pressure). For the Constellation Program, the flammability threshold information will allow NASA to identify materials with increased flammability risk because of oxygen concentration and total pressure changes, minimize potential impacts, and allow for development of sound requirements for new spacecraft and extraterrestrial landers and habitats.

  7. Dynamic Changes in Yeast Phosphatase Families Allow for Specialization in Phosphate and Thiamine Starvation.

    PubMed

    Nahas, John V; Iosue, Christine L; Shaik, Noor F; Selhorst, Kathleen; He, Bin Z; Wykoff, Dennis D

    2018-05-10

    Convergent evolution is often due to selective pressures generating a similar phenotype. We observe relatively recent duplications in a spectrum of Saccharomycetaceae yeast species resulting in multiple phosphatases that are regulated by different nutrient conditions - thiamine and phosphate starvation. This specialization is both transcriptional and at the level of phosphatase substrate specificity. In Candida glabrata , loss of the ancestral phosphatase family was compensated by the co-option of a different histidine phosphatase family with three paralogs. Using RNA-seq and functional assays, we identify one of these paralogs, CgPMU3 , as a thiamine phosphatase. We further determine that the 81% identical paralog CgPMU2 does not encode thiamine phosphatase activity; however, both are capable of cleaving the phosphatase substrate, 1-napthyl-phosphate. We functionally demonstrate that members of this family evolved novel enzymatic functions for phosphate and thiamine starvation, and are regulated transcriptionally by either nutrient condition, and observe similar trends in other yeast species. This independent, parallel evolution involving two different families of histidine phosphatases suggests that there were likely similar selective pressures on multiple yeast species to recycle thiamine and phosphate. In this work, we focused on duplication and specialization, but there is also repeated loss of phosphatases, indicating that the expansion and contraction of the phosphatase family is dynamic in many Ascomycetes. The dynamic evolution of the phosphatase gene families is perhaps just one example of how gene duplication, co-option, and transcriptional and functional specialization together allow species to adapt to their environment with existing genetic resources. Copyright © 2018, G3: Genes, Genomes, Genetics.

  8. Accountability Pressure and Non-Achievement Student Behaviors. Working Paper 122

    ERIC Educational Resources Information Center

    Holbein, John B.; Ladd, Helen F.

    2015-01-01

    In this paper we examine how failing to make adequate yearly progress under No Child Left Behind (NCLB), and the accountability pressure that ensues, affects various non-achievement student behaviors. Using administrative data from North Carolina and leveraging a discontinuity in the determination of school failure, we examine the causal impact of…

  9. Blood Pressure Measurement: Clinic, Home, Ambulatory, and Beyond

    PubMed Central

    Drawz, Paul E.; Abdalla, Mohamed; Rahman, Mahboob

    2014-01-01

    Blood pressure has traditionally been measured in the clinic setting using the auscultory method and a mercury sphygmomanometer. Technological advances have led to improvements in measuring clinic blood pressure and allowed for measuring blood pressures outside the clinic. This review outlines various methods for evaluating blood pressure and the clinical utility of each type of measurement. Home blood pressures and 24 hour ambulatory blood pressures have improved our ability to evaluate risk for target organ damage and hypertension related morbidity and mortality. Measuring home blood pressures may lead to more active participation in health care by patients and has the potential to improve blood pressure control. Ambulatory blood pressure monitoring enables the measuring nighttime blood pressures and diurnal changes, which may be the most accurate predictors of risk associated with elevated blood pressure. Additionally, reducing nighttime blood pressure is feasible and may be an important component of effective antihypertensive therapy. Finally, estimating central aortic pressures and pulse wave velocity are two of the newer methods for assessing blood pressure and hypertension related target organ damage. PMID:22521624

  10. Permeability - Fluid Pressure - Stress Relationship in Fault Zones in Shales

    NASA Astrophysics Data System (ADS)

    Henry, P.; Guglielmi, Y.; Morereau, A.; Seguy, S.; Castilla, R.; Nussbaum, C.; Dick, P.; Durand, J.; Jaeggi, D.; Donze, F. V.; Tsopela, A.

    2016-12-01

    Fault permeability is known to depend strongly on stress and fluid pressures. Exponential relationships between permeability and effective pressure have been proposed to approximate fault response to fluid pressure variations. However, the applicability of these largely empirical laws remains questionable, as they do not take into account shear stress and shear strain. A series of experiments using mHPP probes have been performed within fault zones in very low permeability (less than 10-19 m2) Lower Jurassic shale formations at Tournemire (France) and Mont Terri (Switzerland) underground laboratories. These probes allow to monitor 3D displacement between two points anchored to the borehole walls at the same time as fluid pressure and flow rate. In addition, in the Mont-Terri experiment, passive pressure sensors were installed in observation boreholes. Fracture transmissivity was estimated from single borehole pulse test, constant pressure injection tests, and cross-hole tests. It is found that the transmissivity-pressure dependency can be approximated with an exponential law, but only above a pressure threshold that we call the Fracture Opening Threshold (F.O.P). The displacement data show a change of the mechanical response across the F.O.P. The displacement below the F.O.P. is dominated by borehole response, which is mostly elastic. Above F.O.P., the poro-elasto-plastic response of the fractures dominates. Stress determinations based on previous work and on the analysis of slip data from mHPPP probe indicate that the F.O.P. is lower than the least principal stress. Below the F.O.P., uncemented fractures retain some permeability, as pulse tests performed at low pressures yield diffusivities in the range 10-2 to 10-5 m2/s. Overall, this dual behavior appears consistent with the results of CORK experiments performed in accretionary wedge decollements. Results suggest (1) that fault zones become highly permeable when approaching the critical Coulomb threshold (2

  11. An alternating pressure sequence proposal for an air-cell cushion for preventing pressure ulcers.

    PubMed

    Arias, Sandra; Cardiel, Eladio; Rogeli, Pablo; Mori, Taketoshi; Nakagami, Gojiro; Noguchi, Hiroshi; Sanada, Hiromi

    2014-01-01

    The distribution and release of pressure on ischial regions are two important parameters for evaluating the effectiveness of a cushion; especially the release of pressure over time on ischial tuberosities, which is significant for preventing pressure ulcers. The aim of this work is to evaluate the effect on interface pressure through the application of a proposed alternating pressure sequence for an air-cell cushion. Six healthy volunteers were asked to sit on the air cell cushion, in static and alternating modes, as well as on a typical foam cushion for 12 minutes. Interface pressure was monitored with a matrix sensor system. Interface pressure values on ischial tuberosities, user contact area and pressure distribution were analyzed. Results showed that IP on IT tends to increase in both foam and static cushions, while in alternating cushion IP on IT tends to decrease. User contact area was significantly larger in alternating cushion than in static or foam cushions. Moreover, there is a better pressure re-distribution with alternating cushion than with the other cushions. The goal of the alternating sequence is to redistribute pressure and stimulate the ischial regions in order to promote blood flow and prevent pressure occurring in wheelchair users.

  12. Variation of Pressure with Depth of Water: Working with High-Tech and Low-Cost Materials

    ERIC Educational Resources Information Center

    Ornek, Funda; Zziwa, Byansi Jude; Taganahan, Teresita D.

    2013-01-01

    When you dive underwater, you feel the pressure on your ears and, as you dive deeper, more pressure is felt. This article presents an activity that teachers might find useful for demonstrating the relationship between water depth and pressure. (Contains 5 figures and 1 table.)

  13. Sound Exposure of Healthcare Professionals Working with a University Marching Band.

    PubMed

    Russell, Jeffrey A; Yamaguchi, Moegi

    2018-01-01

    Music-induced hearing disorders are known to result from exposure to excessive levels of music of different genres. Marching band music, with its heavy emphasis on brass and percussion, is one type that is a likely contributor to music-induced hearing disorders, although specific data on sound pressure levels of marching bands have not been widely studied. Furthermore, if marching band music does lead to music-induced hearing disorders, the musicians may not be the only individuals at risk. Support personnel such as directors, equipment managers, and performing arts healthcare providers may also be exposed to potentially damaging sound pressures. Thus, we sought to explore to what degree healthcare providers receive sound dosages above recommended limits during their work with a marching band. The purpose of this study was to determine the sound exposure of healthcare professionals (specifically, athletic trainers [ATs]) who provide on-site care to a large, well-known university marching band. We hypothesized that sound pressure levels to which these individuals were exposed would exceed the National Institute for Occupational Safety and Health (NIOSH) daily percentage allowance. Descriptive observational study. Eight ATs working with a well-known American university marching band volunteered to wear noise dosimeters. During the marching band season, ATs wore an Etymotic ER-200D dosimeter whenever working with the band at outdoor rehearsals, indoor field house rehearsals, and outdoor performances. The dosimeters recorded dose percent exposure, equivalent continuous sound levels in A-weighted decibels, and duration of exposure. For comparison, a dosimeter also was worn by an AT working in the university's performing arts medicine clinic. Participants did not alter their typical duties during any data collection sessions. Sound data were collected with the dosimeters set at the NIOSH standards of 85 dBA threshold and 3 dBA exchange rate; the NIOSH 100% daily dose is

  14. Nurses' attitudes towards pressure ulcer prevention in Turkey.

    PubMed

    Aslan, Arzu; Yavuz van Giersbergen, Meryem

    2016-02-01

    Pressure ulcers remain a major problem in healthcare system. Pressure ulcer incidence is widely accepted as an indicator for the quality of care. Positive attitudes towards pressure ulcer prevention have positive impacts on preventive care. The aim of this study was to identify nurses' attitude towards pressure ulcer prevention. The study design was descriptive. The study was carried out in a university hospital in Izmir, Turkey. The study population consisted of 660 nurses who work in medical and surgical clinics and intensive care units. The study sample consisted of 426 nurses who agreed to participate. Attitude towards Pressure Ulcer Prevention Instrument was used in order to evaluate nurses' attitudes. Written permissions for ethical considerations and Attitude towards Pressure Ulcer Prevention Instrument permission were obtained. Data were collected between June and July 2014. The statistics program SPSS 18 packaged software was used in the analyses of data. The average age of the nurses who took part in the study was 31.86 ± 7.09 years and the average work experience was 8.88 ± 7.41 years; 36.9% (n: 157) were working in intensive care units. The nurses' average score on the Attitude towards Pressure Ulcer Prevention Instrument was 43.74 ± 4.29 (84.12%). It was seen that the attitudes of the nurses towards the prevention of pressure ulcers was positive. To read guidelines and training time about pressure ulcer prevention affect positively attitudes towards the prevention of pressure ulcers. Copyright © 2015 Tissue Viability Society. Published by Elsevier Ltd. All rights reserved.

  15. Pressurized security barrier and alarm system

    DOEpatents

    Carver, Don W.

    1995-01-01

    A security barrier for placement across a passageway is made up of interconnected pressurized tubing made up in a grid pattern with openings too small to allow passage. The tubing is connected to a pressure switch, located away from the barrier site, which activates an alarm upon occurrence of a pressure drop. A reinforcing bar is located inside and along the length of the tubing so as to cause the tubing to rupture and set off the alarm upon an intruder's making an attempt to crimp and seal off a portion of the tubing by application of a hydraulic tool. Radial and rectangular grid patterns are disclosed.

  16. Pressurized security barrier and alarm system

    DOEpatents

    Carver, D.W.

    1995-04-11

    A security barrier for placement across a passageway is made up of interconnected pressurized tubing made up in a grid pattern with openings too small to allow passage. The tubing is connected to a pressure switch, located away from the barrier site, which activates an alarm upon occurrence of a pressure drop. A reinforcing bar is located inside and along the length of the tubing so as to cause the tubing to rupture and set off the alarm upon an intruder`s making an attempt to crimp and seal off a portion of the tubing by application of a hydraulic tool. Radial and rectangular grid patterns are disclosed. 7 figures.

  17. Understanding the Clausius-Clapeyron Equation by Employing an Easily Adaptable Pressure Cooker

    ERIC Educational Resources Information Center

    Galleano, Monica; Boveris, Alberto; Puntarulo, Susana

    2008-01-01

    This article describes a simple and inexpensive laboratory exercise developed to understand the effect of pressure on phase equilibrium as described by the Clausius-Clapeyron equation. The only piece of equipment required is a pressure cooker adapted with a pressure gauge and a thermometer in the lid, allowing the measurement of the pressure and…

  18. Intra-ocular pressure normalization technique and equipment

    NASA Technical Reports Server (NTRS)

    Mcgannon, W. J. (Inventor)

    1980-01-01

    A method and apparatus for safely reducing abnormally high intraocular pressure in an eye during a predetermined time interval is presented. This allows maintenance of normal intraocular pressure during glaucoma surgery. According to the invention, a pressure regulator of the spring biased diaphragm type is provided with additional bias by a column of liquid. The height of the column of liquid is selected such that the pressure at a hypodermic needle connected to the output of the pressure regulator is equal to the measured pressure of the eye. The hypodermic needle can then be safely inserted into the anterior chamber of the eye. Liquid is then bled out of the column to reduce the bias on the diaphragm of the pressure regulator and, consequently, the output pressure of the regulator. This lowering pressure of the regulator also occurs in the eye by means of a small second bleed path provided between the pressure regulator and the hypodermic needle. Alternately, a second hypodermic needle may be inserted into the eye to provide a controlled leak off path for excessive pressure and clouded fluid from the anterior chamber.

  19. White-collar workers' hemodynamic responses during working hours.

    PubMed

    Liu, Xinxin; Iwakiri, Kazuyuki; Sotoyama, Midori

    2017-08-08

    In the present study, two investigations were conducted at a communication center, to examine white-collar workers' hemodynamic responses during working hours. In investigation I, hemodynamic responses were measured on a working day; and in investigation II, cardiovascular responses were verified on both working and non-working days. In investigation I, blood pressure, cardiac output, heart rate, stroke volume, and total peripheral resistance were measured in 15 workers during working hours (from 9:00 am to 18:00 pm) on one working day. Another 40 workers from the same workplace participated in investigation II, in which blood pressure and heart rate were measured between the time workers arose in the morning until they went to bed on 5 working days and 2 non-working days. The results showed that blood pressure increased and remained at the same level during working hours. The underlying hemodynamics of maintaining blood pressure, however, changed between the morning and the afternoon on working days. Cardiac responses increased in the afternoon, suggesting that cardiac burdens increase in the afternoon on working days. The present study suggested that taking underlying hemodynamic response into consideration is important for managing the work-related cardiovascular burden of white-collar workers.

  20. White-collar workers’ hemodynamic responses during working hours

    PubMed Central

    LIU, Xinxin; IWAKIRI, Kazuyuki; SOTOYAMA, Midori

    2017-01-01

    In the present study, two investigations were conducted at a communication center, to examine white-collar workers’ hemodynamic responses during working hours. In investigation I, hemodynamic responses were measured on a working day; and in investigation II, cardiovascular responses were verified on both working and non-working days. In investigation I, blood pressure, cardiac output, heart rate, stroke volume, and total peripheral resistance were measured in 15 workers during working hours (from 9:00 am to 18:00 pm) on one working day. Another 40 workers from the same workplace participated in investigation II, in which blood pressure and heart rate were measured between the time workers arose in the morning until they went to bed on 5 working days and 2 non-working days. The results showed that blood pressure increased and remained at the same level during working hours. The underlying hemodynamics of maintaining blood pressure, however, changed between the morning and the afternoon on working days. Cardiac responses increased in the afternoon, suggesting that cardiac burdens increase in the afternoon on working days. The present study suggested that taking underlying hemodynamic response into consideration is important for managing the work-related cardiovascular burden of white-collar workers. PMID:28428502

  1. High pressure far infrared spectroscopy of ionic solids

    NASA Technical Reports Server (NTRS)

    Lowndes, R. P.

    1974-01-01

    A high-pressure far-infrared cell operating at up to truly hydrostatic pressures of 8 kbar is described and used to determine the anharmonic self-energies associated with the transverse optic modes of ionic solids in which q approximately equals zero. The cell allows far-infrared studies in the spectral range below 120 reciprocal cm. The transverse optic modes were investigated to determine their mode Gruneisen constants and the pressure dependence of their inverse lifetimes in RbI, CsI, and TlCl.

  2. Work time, work interference with family, and psychological distress.

    PubMed

    Major, Virginia Smith; Klein, Katherine J; Ehrhart, Mark G

    2002-06-01

    Despite public concern about time pressures experienced by working parents, few scholars have explicitly examined the effects of work time on work-family conflict. The authors developed and tested a model of the predictors of work time and the relationships between time, work interference with family (WIF). and psychological distress. Survey data came from 513 employees in a Fortune 500 company. As predicted, several work and family characteristics were significantly related to work time. In addition, work time was significantly, positively related to WIF, which in turn was significantly, negatively related to distress. The results suggest that work time fully or partially mediates the effects of many work and family characteristics on WIF.

  3. Tensions between work and home: job quality and working conditions in the institutional contexts of Germany and Spain.

    PubMed

    Drobnič, Sonja; Guillén Rodríguez, Ana M

    2011-01-01

    Good jobs can generate capabilities that allow employees to avoid tensions between work and family/home. Following the conceptual framework of Amartya Sen, we examine how job-related demands and resources are related to the level of interference, as well as satisfaction with managing work and home in Spanish and German employees, using three different large-scale European surveys: European Quality of Life Survey and two waves of the European Social Survey. We find that long working hours systematically increase tensions between work and home, as do time pressure, job-related stress, and working hard. Job control or autonomy at work, which is hypothesized to expand individuals' capabilities and agency, tends to increase work–home interference rather than alleviate it. Family responsibilities and household demands do not seem relevant to the tensions employees experience at the work–home interface. This also holds true for women, which is a surprising result in view of the “double burden” hypothesis. Employed mothers in Germany and Spain are a select group of women, as combining employment with raising children in conservative–corporatist and conservative–familialist states may be particularly problematic. Thus while the institutional contexts of Germany and Spain curtail women's ability to reconcile employment and parenthood, the mothers (and fathers) who are employed do not experience significantly higher levels of work–family/home tensions than nonparents.

  4. Pressure-Letdown Machine for a Coal Reactor

    NASA Technical Reports Server (NTRS)

    Perkins, G. S.; Mabe, W. B.

    1986-01-01

    Pumps operating in reverse generate power. Conceptual pressure-letdown machine for coal-liquefaction system extracts energy from expansion of product fluid. Mud pumps, originally intended for use in oil drilling, operated in reverse so their motors act as generators. Several pumps operated in alternating phase to obtain multiple stages of letdown from inlet pressure to outlet pressure. About 75 percent of work generates inlet pressure recoverable as electrical energy.

  5. Everyone is working together to ease the pressures in A&E.

    PubMed

    Kimber, Mark

    2015-01-27

    Nurse consultant Janet Youd, chair of the RCN Emergency Care Association, says nurses struggling to cope with unprecedented pressures in A&E departments should be awarded an extra half day's annual leave (Online News January 8).

  6. High-pressure autoclave for multipurpose nuclear magnetic resonance measurements up to 10 MPa

    NASA Astrophysics Data System (ADS)

    Behr, W.; Haase, A.; Reichenauer, G.; Fricke, J.

    1999-05-01

    High-pressure nuclear magnetic resonance (NMR) is an established method in NMR spectroscopy: on-line coupling of high-performance liquid chromatography with NMR, for example, reveals structural information which cannot be obtained with any other method. However, applications has been focused solely on high-pressure NMR spectroscopy, even though high-pressure NMR imaging allows in situ studies of processes such as the fluid exchange in porous media. A versatile high-pressure autoclave for NMR imaging is described in this article. The autoclave allows measurements in any horizontal NMR imager using magnetic field coil systems with an inside diameter of more than 70 mm. Any sample with a diameter up to 28 mm and a length of about 200 mm can be investigated. The autoclave is constructed for operating pressures up to 10 MPa and is temperature controlled between 10 and 60 °C. The materials of the high-pressure cell which are the thermoplastic polyetheretherketon (PEEK) for the pressure tube and brass (63% Cu, 37% Zn) for the caps also permit investigations with aggressive fluids such as supercritical carbon dioxide. Inlet and outlet valves allow replacement of fluids and pressure variations in the autoclave during the NMR measurement. FLASH NMR images of the fluid exchange of methanol for liquid carbon dioxide in silica alcogels at 6.5 MPa are presented in order to demonstrate possible applications.

  7. Hydrostatic Paradox: Experimental Verification of Pressure Equilibrium

    ERIC Educational Resources Information Center

    Kodejška, C.; Ganci, S.; Ríha, J.; Sedlácková, H.

    2017-01-01

    This work is focused on the experimental verification of the balance between the atmospheric pressure acting on the sheet of paper, which encloses the cylinder completely or partially filled with water from below, where the hydrostatic pressure of the water column acts against the atmospheric pressure. First of all this paper solves a theoretical…

  8. High Precision Pressure Measurement with a Funnel

    ERIC Educational Resources Information Center

    Lopez-Arias, T.; Gratton, L. M.; Oss, S.

    2008-01-01

    A simple experimental device for high precision differential pressure measurements is presented. Its working mechanism recalls that of a hydraulic press, where pressure is supplied by insufflating air under a funnel. As an application, we measure air pressure inside a soap bubble. The soap bubble is inflated and connected to a funnel which is…

  9. Blood Pressure, Sleep Quality and Fatigue in Shift Working Police Officers: Effects of a Twelve Hour Roster System on Cardiovascular and Sleep Health.

    PubMed

    Elliott, Jaymen L; Lal, Sara

    2016-01-29

    Police officers have been reported to exhibit a high incidence of pathologies, which present prematurely in an otherwise healthy population. Shift work has also been associated with an increased risk of cardiovascular and sleep disorders, attributable to its propensity for circadian rhythm dysfunction. However, contention exists as to whether shift work has a direct effect upon blood pressure (BP) regulation. This cross-sectional study sought to determine changes in BP and associations with the overall sleep quality and fatigue in 206 general duties police officers (n = 140 males) of the New South Wales Police Force in Australia. The subjects' BP was assessed before and after their twelve hour shift, during which time they also completed the Lifestyle Appraisal Questionnaire, Pittsburgh Sleep Quality Index (PSQI), Epworth Sleepiness Scale and Fatigue Severity Scale (FSS). Poor sleep quality (PSQI) and fatigue severity (FSS) were found to predominate in the sample (69% and 51% respectively). Although there was no change in BP for male participants, female officers' systolic blood pressure (SBP) was found to increase significantly across the shift (p < 0.001), but with no change found in females' diastolic blood pressure (DBP). Finally, higher pre and post-shift SBP (r = -0.26, p = 0.001; r = -0.25, p = 0.001, respectively) and DBP (r = -0.26, p = 0.001; r = -0.26, p = 0.001, respectively) were significantly correlated with lower FSS scores after accounting for age, waist-hip ratio and lifestyle risk factors. Based on these preliminary findings, there was a significant increase in SBP of female police officers after shift work, while BP and fatigue levels in all police officers were strongly related. Moreover, the predominating poor sleep quality and impact of fatigue in this sample remain a concern. Further research is required to ensure the physiological welfare of police officers, while strategies must be implemented to manage the detrimental effects shift work

  10. Estimating right ventricular stroke work and the pulsatile work fraction in pulmonary hypertension.

    PubMed

    Chemla, Denis; Castelain, Vincent; Zhu, Kaixian; Papelier, Yves; Creuzé, Nicolas; Hoette, Susana; Parent, Florence; Simonneau, Gérald; Humbert, Marc; Herve, Philippe

    2013-05-01

    The mean pulmonary artery pressure (mPAP) replaces mean systolic ejection pressure (msePAP) in the classic formula of right ventricular stroke work (RVSW) = (mPAP - RAP) × stroke volume, where RAP is mean right atrial pressure. Only the steady work is thus taken into account, not the pulsatile work, whereas pulmonary circulation is highly pulsatile. Our retrospective, high-fidelity pressure study tested the hypothesis that msePAP was proportional to mPAP, and looked at the implications for RVSW. Eleven patients with severe, precapillary pulmonary hypertension (PH) (six patients with idiopathic pulmonary arterial hypertension and five with chronic thromboembolic PH; mPAP = 57 ± 10 mm Hg) were studied at rest and during mild to moderate exercise. Eight non-PH control subjects were also studied at rest (mPAP = 16 ± 2 mm Hg). The msePAP was averaged from end diastole to dicrotic notch. In the full data set (53 pressure-flow points), mPAP ranged from 14 to 99.5 mm Hg, cardiac output from 2.38 to 11.1 L/min, and heart rate from 53 to 163 beats/min. There was a linear relationship between msePAP and mPAP (r² = 0.99). The msePAP matched 1.25 mPAP (bias, -0.5 ± 2.6 mm Hg). Results were similar in the resting non-PH group and in resting and the exercising PH group. This implies that the classic formula markedly underestimates RVSW and that the pulsatile work may be a variable 20% to 55% fraction of RVSW, depending on RAP and mPAP. At rest, RVSW in patients with PH was twice as high as that of the non-PH group (P < .05), but pulsatile work fraction was similar between the two groups (26 ± 4% vs 24 ± 1%) because of the counterbalancing effects of high RAP (11 ± 5 mm Hg vs 4 ± 2 mm Hg), which increases the fraction, and high mPAP, which decreases the fraction. Our study favored the use of an improved formula that takes into account the variable pulsatile work fraction: RVSW = (1.25 mPAP - RAP) × stroke volume. Increased RAP and increased mPAP have opposite effects on

  11. Effect of thermal pressurization on dynamic rupture propagation under depth-dependent stress

    NASA Astrophysics Data System (ADS)

    Urata, Y.; Kuge, K.; Kase, Y.

    2009-12-01

    Fluid and pore pressure evolution can affect dynamic propagation of earthquake ruptures owing to thermal pressurization (e.g., Mase and Smith, 1985). We investigate dynamic rupture propagation with thermal pressurization on a fault subjected to depth-dependent stress, on the basis of 3-D numerical simulations for spontaneous dynamic ruptures. We put a vertical strike-slip rectangular fault in a semi-infinite, homogenous, and elastic medium. The length and width of the fault are 8 and 3 km, respectively. We assume a depth-dependent stress estimated by Yamashita et al. (2004). The numerical algorithm is based on the finite-difference method by Kase and Kuge (2001). A rupture is initiated by increasing shear stress in a small patch at the bottom of the fault, and then proceeds spontaneously, governed by a slip-weakening law with the Coulomb failure criteria. Coefficients of friction and Dc are homogeneous on the fault. On a fault with thermal pressurization, we allow effective normal stress to vary with pore pressure change due to frictional heating by the formulation of Bizzarri and Cocco (2006). When thermal pressurization does not work, tractions drop in the same way everywhere and rupture velocity is subshear except near the free surface. Due to thermal pressurization, dynamic friction on the fault decreases and is heterogeneous not only vertically but horizontally, slip increases, and rupture velocity along the strike direction becomes supershear. As a result, plural peaks of final slip appear, as observed in the case of undrained dip-slip fault by Urata et al. (2008). We found in this study that the early stage of rupture growth under the depth-dependent stress is affected by the location of an initial crack. When a rupture is initiated at the center of the fault without thermal pressurization, the rupture cannot propagate and terminates. Thermal pressurization can help such a powerless rupture to keep propagating.

  12. Flexible suspended gate organic thin-film transistors for ultra-sensitive pressure detection

    NASA Astrophysics Data System (ADS)

    Zang, Yaping; Zhang, Fengjiao; Huang, Dazhen; Gao, Xike; di, Chong-An; Zhu, Daoben

    2015-03-01

    The utilization of organic devices as pressure-sensing elements in artificial intelligence and healthcare applications represents a fascinating opportunity for the next-generation electronic products. To satisfy the critical requirements of these promising applications, the low-cost construction of large-area ultra-sensitive organic pressure devices with outstanding flexibility is highly desired. Here we present flexible suspended gate organic thin-film transistors (SGOTFTs) as a model platform that enables ultra-sensitive pressure detection. More importantly, the unique device geometry of SGOTFTs allows the fine-tuning of their sensitivity by the suspended gate. An unprecedented sensitivity of 192 kPa-1, a low limit-of-detection pressure of <0.5 Pa and a short response time of 10 ms were successfully realized, allowing the real-time detection of acoustic waves. These excellent sensing properties of SGOTFTs, together with their advantages of facile large-area fabrication and versatility in detecting various pressure signals, make SGOTFTs a powerful strategy for spatial pressure mapping in practical applications.

  13. Wireless, Ultra-Low-Power Implantable Sensor for Chronic Bladder Pressure Monitoring.

    PubMed

    Majerus, Steve J A; Garverick, Steven L; Suster, Michael A; Fletter, Paul C; Damaser, Margot S

    2012-06-01

    The wireless implantable/intracavity micromanometer (WIMM) system was designed to fulfill the unmet need for a chronic bladder pressure sensing device in urological fields such as urodynamics for diagnosis and neuromodulation for bladder control. Neuromodulation in particular would benefit from a wireless bladder pressure sensor which could provide real-time pressure feedback to an implanted stimulator, resulting in greater bladder capacity while using less power. The WIMM uses custom integrated circuitry, a MEMS transducer, and a wireless antenna to transmit pressure telemetry at a rate of 10 Hz. Aggressive power management techniques yield an average current draw of 9 μ A from a 3.6-Volt micro-battery, which minimizes the implant size. Automatic pressure offset cancellation circuits maximize the sensing dynamic range to account for drifting pressure offset due to environmental factors, and a custom telemetry protocol allows transmission with minimum overhead. Wireless operation of the WIMM has demonstrated that the external receiver can receive the telemetry packets, and the low power consumption allows for at least 24 hours of operation with a 4-hour wireless recharge session.

  14. Wireless, Ultra-Low-Power Implantable Sensor for Chronic Bladder Pressure Monitoring

    PubMed Central

    MAJERUS, STEVE J. A.; GARVERICK, STEVEN L.; SUSTER, MICHAEL A.; FLETTER, PAUL C.; DAMASER, MARGOT S.

    2015-01-01

    The wireless implantable/intracavity micromanometer (WIMM) system was designed to fulfill the unmet need for a chronic bladder pressure sensing device in urological fields such as urodynamics for diagnosis and neuromodulation for bladder control. Neuromodulation in particular would benefit from a wireless bladder pressure sensor which could provide real-time pressure feedback to an implanted stimulator, resulting in greater bladder capacity while using less power. The WIMM uses custom integrated circuitry, a MEMS transducer, and a wireless antenna to transmit pressure telemetry at a rate of 10 Hz. Aggressive power management techniques yield an average current draw of 9 μA from a 3.6-Volt micro-battery, which minimizes the implant size. Automatic pressure offset cancellation circuits maximize the sensing dynamic range to account for drifting pressure offset due to environmental factors, and a custom telemetry protocol allows transmission with minimum overhead. Wireless operation of the WIMM has demonstrated that the external receiver can receive the telemetry packets, and the low power consumption allows for at least 24 hours of operation with a 4-hour wireless recharge session. PMID:26778926

  15. Work family conflict in its relations to perceived working situation and work engagement.

    PubMed

    Mache, Stefanie; Bernburg, Monika; Groneberg, David A; Klapp, Burghard F; Danzer, Gerhard

    2016-02-15

    These days physicians' work is characterized by an increase in economic demands, pressure and challenges in establishing a balance between work and family life. The current study investigates the relationship between physicians' job demands and resources, perceived job stress, work-family conflict, work engagement and job satisfaction. 564 clinicians specialising in different medical fields participated in the cross-sectional study. Self-administered questionnaires, including the COPSOQ and the UWES- Scale were administered. Our results illustrated significant relationships between physicians' work engagement and their job satisfaction as well as between job stress and work family conflict. Moreover, perceived job stress moderated the effect of high job demands on work family conflict. In addition, significant gender differences have been found in perceived stress levels, work family conflict and work engagement. This study proves and verified associations between work engagement, work-family conflict, job demands and resources that may influence employees' satisfaction. Implications for both working physicians and hospital management are given.

  16. Capabilities of a New Pressure Controller for Gas-Controlled Heat Pipes

    NASA Astrophysics Data System (ADS)

    Giunta, S.; Merlone, A.; Marenco, S.; Marcarino, P.; Tiziani, A.

    2008-10-01

    Pressure control is used in many metrological applications and for the control of thermodynamic quantities. At the Italian National Research Institute of Metrology (INRiM), a new pressure controller has been designed and assembled, operating in the pressure range between 4 kPa and 400 kPa. This innovative instrument uses a commercial pressure transducer with a sensitivity of 10-4 and several electro-valves interposed among calibrated volumes of different dimensions in order to realize known ratios for very fine pressure changes. The device is provided with several circuits to drive the electro-valve actions, for signal processing and transmission, and for both manual and automatic control. Input/output peripherals, such as a 4 × 20 dot matrix display and a 4 × 4 keyboard, allow setting of the parameters and data visualization, while a remote control port allows interfacing with a computer. The operating principle of this pressure controller has been recently applied, with excellent results, to control the pressure in gas-controlled heat pipes by using a standard platinum resistance thermometer as a temperature/pressure sensor, achieving in this case a relative sensitivity better than 10-6 in pressure. Several tests were also made to control the pressure by means of a commercial sensor. The device, its main components, and its capabilities are here reported, together with application tests and results.

  17. Pressure effect on dissimilatory sulfate reduction

    NASA Astrophysics Data System (ADS)

    Williamson, A. J.; Carlson, H. K.; Coates, J. D.

    2015-12-01

    Biosouring is the production of H2S by sulfate reducing microorganisms (SRM) in-situ or in the produced fluids of oil reservoirs. Sulfide is explosive, toxic and corrosive which can trigger equipment and transportation failure, leading to environmental catastrophe. As oil exploration and reservoir development continue, subsequent enhanced recovery is occurring in progressively deeper formations and typical oil reservoir pressures range from 10-50 MPa. Therefore, an understanding of souring control effects will require an accurate understanding of the influence of pressure on SRM metabolism and the efficacy of souring control treatments at high pressure. Considerable work to date has focussed on souring control at ambient pressure; however, the influence of pressure on biogeochemical processes and souring treatments in oil reservoirs is poorly understood. To explore the impact of pressure on SRM, wild type Desulfovibrio alaskensis G20 (isolated from a producing oil well in Ventura County, California) was grown under a range of pressures (0.1-14 MPa) at 30 °C. Complete sulfate reduction occurred in all pressures tested within 3 days, but microbial growth was inhibited with increasing pressure. Bar-seq identified several genes associated with flagella biosynthesis (including FlhB) and assembly as important for survival at elevated pressure and fitness was confirmed using individual transposon mutants. Flagellar genes have previously been implicated with biofilm formation and confocal microscopy on glass slides incubated with wild type D. alaskensis G20 showed more biomass associated with surfaces under pressure, highlighting the link between pressure, flagellar and biofilm formation. To determine the effect of pressure on the efficacy of SRM inhibitors, IC50 experiments were conducted and D. alaskensis G20 showed a greater resistance to nitrate and the antibiotic chloramphenicol, but a lower resistance to perchlorate. These results will be discussed in the context of

  18. Funding child rearing: child allowance and parental leave.

    PubMed

    Walker, J R

    1996-01-01

    This article proposes two financing plans to address what the author identifies as the two primary concerns in the child care field: (1) a child allowance for poor and near-poor households to address the child care problems of low-income families, and (2) a program of voluntary parental leave, available to all parents at child birth or adoption, to ensure the adequacy of infant care. The child allowance plan would cover the first three children in families up to 175% of the poverty level (more than 22 million children) at an annual cost of $45 billion. The author suggests that the allowance could be financed by redirecting funds from existing income support (for example, Aid to Families with Dependent Children), tax credit, and tax deduction programs. Financing the parental leave program would require new revenues, generated by an employee-paid increase in payroll tax totaling 3.5%. Each employee's contributions would create a parental leave account (PLA). Families could use the funds in these accounts to cover the cost of a one-year leave from work after the birth or adoption of a child. If families did not have enough dollars in their accounts to cover the cost of the leave, the federal government would extend a low-interest loan to them, which they would have to pay back. The amount individuals receive through Social Security would be adjusted upward or downward according to the balances in their parental leave accounts at retirement. The author suggests that both proposals would help parents balance work and family obligations and protect parental freedom of choice over the care and upbringing of their children.

  19. Detailed Analysis of ECMWF Surface Pressure Data

    NASA Astrophysics Data System (ADS)

    Fagiolini, E.; Schmidt, T.; Schwarz, G.; Zenner, L.

    2012-04-01

    Investigations of temporal variations within the gravity field of the Earth led us to the analysis of common surface pressure data products delivered by ECMWF. We looked into the characteristics of global as well as spatially and temporally confined phenomena being visible in the data. In particular, we were interested in the overall data quality, the local and temporal signal-to-noise ratio of surface pressure data sets, and the identification of irregular data. To this end, we analyzed a time series of a full year of surface pressure operational analysis data and their nominal standard deviations. The use of pressure data on a Gaussian grid data allowed us to remain close to the internal computations at ECMWF during data assimilation. Thus, we circumvented potential interpolation effects that would otherwise occur in cylindrical projections of conventional map products. The results obtained by us demonstrate the identification of a few distinct outliers, data quality effects over land or water and along coastlines as well as neighborhood effects of samples within and outside of the tropics. Small scale neighborhood effects depend on their geographical direction, sampling distance, land or water, and local time. In addition, one notices large scale seasonal effects that are latitude and longitude dependent. As a consequence, we obtain a cause-and-effect survey of pressure data peculiarities. One can then use background corrected pressure data to analyze seasonal effects within given latitude belts. Here time series of pressure data allow the tracking of high and low pressure areas together with the identification of their actual extent, velocity and life time. This information is vital to overall mass transport calculations and the determination of temporally varying gravity fields. However, one has to note that the satellite and ground-based instruments and the assimilation software being used for the pressure calculations will not remain the same over the years

  20. Ultrahigh-Sensitivity Piezoresistive Pressure Sensors for Detection of Tiny Pressure.

    PubMed

    Li, Hongwei; Wu, Kunjie; Xu, Zeyang; Wang, Zhongwu; Meng, Yancheng; Li, Liqiang

    2018-06-20

    High-sensitivity pressure sensors are crucial for the ultrasensitive touch technology and E-skin, especially at the tiny-pressure range below 100 Pa. However, it is highly challenging to substantially promote sensitivity beyond the current level at several to 200 kPa -1 and to improve the detection limit lower than 0.1 Pa, which is significant for the development of pressure sensors toward ultrasensitive and highly precise detection. Here, we develop an efficient strategy to greatly improve the sensitivity near to 2000 kPa -1 using short-channel coplanar device structure and sharp microstructure, which is systematically proposed for the first time and rationalized by the mathematic calculation and analysis. Significantly, benefiting from the ultrahigh sensitivity, the detection limit is improved to be as small as 0.075 Pa. The sensitivity and detection limit are both superior to the current levels and far surpass the function of human skin. Furthermore, the sensor shows fast response time (50 μs), excellent reproducibility and stability, and low power consumption. Remarkably, the sensor shows excellent detection capacity in the tiny-pressure range, including light-emitting diode switching with a pressure of 7 Pa, ringtone (2-20 Pa) recognition, and ultrasensitive (0.1 Pa) electronic glove. This work represents a performance and strategic progress in the field of pressure sensing.

  1. An analysis of collegiate band directors' exposure to sound pressure levels

    NASA Astrophysics Data System (ADS)

    Roebuck, Nikole Moore

    Noise-induced hearing loss (NIHL) is a significant but unfortunate common occupational hazard. The purpose of the current study was to measure the magnitude of sound pressure levels generated within a collegiate band room and determine if those sound pressure levels are of a magnitude that exceeds the policy standards and recommendations of the Occupational Safety and Health Administration (OSHA), and the National Institute of Occupational Safety and Health (NIOSH). In addition, reverberation times were measured and analyzed in order to determine the appropriateness of acoustical conditions for the band rehearsal environment. Sound pressure measurements were taken from the rehearsal of seven collegiate marching bands. Single sample t test were conducted to compare the sound pressure levels of all bands to the noise exposure standards of OSHA and NIOSH. Multiple regression analysis were conducted and analyzed in order to determine the effect of the band room's conditions on the sound pressure levels and reverberation times. Time weighted averages (TWA), noise percentage doses, and peak levels were also collected. The mean Leq for all band directors was 90.5 dBA. The total accumulated noise percentage dose for all band directors was 77.6% of the maximum allowable daily noise dose under the OSHA standard. The total calculated TWA for all band directors was 88.2% of the maximum allowable daily noise dose under the OSHA standard. The total accumulated noise percentage dose for all band directors was 152.1% of the maximum allowable daily noise dose under the NIOSH standards, and the total calculated TWA for all band directors was 93dBA of the maximum allowable daily noise dose under the NIOSH standard. Multiple regression analysis revealed that the room volume, the level of acoustical treatment and the mean room reverberation time predicted 80% of the variance in sound pressure levels in this study.

  2. Nickel hydrogen common pressure vessel battery development

    NASA Technical Reports Server (NTRS)

    Jones, Kenneth R.; Zagrodnik, Jeffrey P.

    1992-01-01

    Our present design for a common pressure vessel (CPV) battery, a nickel hydrogen battery system to combine all of the cells into a common pressure vessel, uses an open disk which allows the cell to be set into a shallow cavity; subsequent cells are stacked on each other with the total number based on the battery voltage required. This approach not only eliminates the assembly error threat, but also more readily assures equal contact pressure to the heat fin between each cell, which further assures balanced heat transfer. These heat fin dishes with their appropriate cell stacks are held together with tie bars which in turn are connected to the pressure vessel weld rings at each end of the tube.

  3. NMR at pressures up to 90 GPa.

    PubMed

    Meier, Thomas; Khandarkhaeva, Saiana; Petitgirard, Sylvain; Körber, Thomas; Lauerer, Alexander; Rössler, Ernst; Dubrovinsky, Leonid

    2018-05-14

    The past 15 years have seen an astonishing increase in Nuclear Magnetic Resonance (NMR) sensitivity and accessible pressure range in high-pressure NMR experiments, owing to a series of new developments of NMR spectroscopy applied to the diamond anvil cell (DAC). Recently, with the application of electro-magnetic lenses, so-called Lenz lenses, in toroidal diamond indenter cells, pressures of up to 72 GPa with NMR spin sensitivities of about 10 12  spin/Hz 1/2 has been achieved. Here, we describe the implementation of a refined NMR resonator structure using a pair of double stage Lenz lenses driven by a Helmholtz coil within a standard DAC, allowing to measure sample volumes as small as 100 pl prior to compression. With this set-up, pressures close to 100 GPa could be realised repeatedly, with enhanced spin sensitivities of about 5 × 10 11 spin/Hz 1/2 . The manufacturing and handling of these new NMR-DACs is relatively easy and straightforward, which will allow for further applications in physics, chemistry, or biochemistry. Copyright © 2018 Elsevier Inc. All rights reserved.

  4. Pressure Regulator With Internal Ejector Circulation Pump, Flow and Pressure Measurement Porting, and Fuel Cell System Integration Options

    NASA Technical Reports Server (NTRS)

    Vasquez, Arturo

    2011-01-01

    An advanced reactant pressure regulator with an internal ejector reactant circulation pump has been developed to support NASA's future fuel cell power systems needs. These needs include reliable and safe operation in variable-gravity environments, and for exploration activities with both manned and un manned vehicles. This product was developed for use in Proton Exchange Membrane Fuel Cell (PEMFC) power plant reactant circulation systems, but the design could also be applied to other fuel cell system types, (e.g., solid-oxide or alkaline) or for other gas pressure regulation and circulation needs. The regulator design includes porting for measurement of flow and pressure at key points in the system, and also includes several fuel cell system integration options. NASA has recognized ejectors as a viable alternative to mechanical pumps for use in spacecraft fuel cell power systems. The ejector motive force is provided by a variable, high-pressure supply gas that travels through the ejector s jet nozzle, whereby the pressure energy of the fluid stream is converted to kinetic energy in the gas jet. The ejector can produce circulation-to-consumption-flow ratios that are relatively high (2-3 times), and this phenomenon can potentially (with proper consideration of the remainder of the fuel cell system s design) be used to provide completely for reactant pre-humidification and product water removal in a fuel cell system. Specifically, a custom pressure regulator has been developed that includes: (1) an ejector reactant circulation pump (with interchangeable jet nozzles and mixer sections, gas-tight sliding and static seals in required locations, and internal fluid porting for pressure-sensing at the regulator's control elements) and (2) internal fluid porting to allow for flow rate and system pressure measurements. The fluid porting also allows for inclusion of purge, relief, and vacuum-breaker check valves on the regulator assembly. In addition, this regulator could also

  5. Pure Niobium as a Pressure Vessel Material

    NASA Astrophysics Data System (ADS)

    Peterson, T. J.; Carter, H. F.; Foley, M. H.; Klebaner, A. L.; Nicol, T. H.; Page, T. M.; Theilacker, J. C.; Wands, R. H.; Wong-Squires, M. L.; Wu, G.

    2010-04-01

    Physics laboratories around the world are developing niobium superconducting radio frequency (SRF) cavities for use in particle accelerators. These SRF cavities are typically cooled to low temperatures by direct contact with a liquid helium bath, resulting in at least part of the helium container being made from pure niobium. In the U.S., the Code of Federal Regulations allows national laboratories to follow national consensus pressure vessel rules or use of alternative rules which provide a level of safety greater than or equal to that afforded by ASME Boiler and Pressure Vessel Code. Thus, while used for its superconducting properties, niobium ends up also being treated as a material for pressure vessels. This report summarizes what we have learned about the use of niobium as a pressure vessel material, with a focus on issues for compliance with pressure vessel codes. We present results of a literature search for mechanical properties and tests results, as well as a review of ASME pressure vessel code requirements and issues.

  6. Modeling conductive heat transfer during high-pressure thawing processes: determination of latent heat as a function of pressure.

    PubMed

    Denys, S; Van Loey, A M; Hendrickx, M E

    2000-01-01

    A numerical heat transfer model for predicting product temperature profiles during high-pressure thawing processes was recently proposed by the authors. In the present work, the predictive capacity of the model was considerably improved by taking into account the pressure dependence of the latent heat of the product that was used (Tylose). The effect of pressure on the latent heat of Tylose was experimentally determined by a series of freezing experiments conducted at different pressure levels. By combining a numerical heat transfer model for freezing processes with a least sum of squares optimization procedure, the corresponding latent heat at each pressure level was estimated, and the obtained pressure relation was incorporated in the original high-pressure thawing model. Excellent agreement with the experimental temperature profiles for both high-pressure freezing and thawing was observed.

  7. Iterative Boltzmann plot method for temperature and pressure determination in a xenon high pressure discharge lamp

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zalach, J.; Franke, St.

    2013-01-28

    The Boltzmann plot method allows to calculate plasma temperatures and pressures if absolutely calibrated emission coefficients of spectral lines are available. However, xenon arcs are not very well suited to be analyzed this way, as there are only a limited number of lines with atomic data available. These lines have high excitation energies in a small interval between 9.8 and 11.5 eV. Uncertainties in the experimental method and in the atomic data further limit the accuracy of the evaluation procedure. This may result in implausible values of temperature and pressure with inadmissible uncertainty. To omit these shortcomings, an iterative schememore » is proposed that is making use of additional information about the xenon fill pressure. This method is proved to be robust against noisy data and significantly reduces the uncertainties. Intentionally distorted synthetic data are used to illustrate the performance of the method, and measurements performed on a laboratory xenon high pressure discharge lamp are analyzed resulting in reasonable temperatures and pressures with significantly reduced uncertainties.« less

  8. Using plastic instability to validate and test the strength law of a material under pressure

    NASA Astrophysics Data System (ADS)

    Bolis, Cyril; Counilh, Denis; Savale, Brice

    2015-09-01

    In dynamical experiments (pressures higher than 10 GPa, strain rate around 104-106 s-1), metals are classically described using an equation of state and a strength law which is usually set using data from compression or traction tests at low pressure (few MPa) and low strain rates (less than 103 s-1). In consequence, it needs to be extrapolated during dynamical experiments. Classical shock experiments do not allow a fine validation of the stress law due to the interaction with the equation of state. To achieve this aim, we propose to use a dedicated experiment. We started from the works of Barnes et al. (1974 and 1980) where plastic instabilities initiated by a sinusoidal perturbation at the surface of the metal develop with the pressure. We adapted this principle to a new shape of initial perturbation and realized several experiments. We will present the setup and its use on a simple material: gold. We will detail how the interpretation of the experiments, coupled with previous characterization experiments helps us to test the strength lax of this material at high pressure and high strain rate.

  9. Astronauts Gemar and Allen work with lower body negative pressure experiment

    NASA Image and Video Library

    1994-03-05

    STS062-07-010 (4-18 March 1994) --- Astronaut Andrew M. Allen, pilot, participates in biomedical testing as he does a "soak" in the Lower Body Negative Pressure (LBNP) apparatus on the Columbia's middeck. Astronaut Charles D. (Sam) Gemar, mission specialist, monitors readouts from the test.

  10. Stress, satisfaction, and the work-family interface: a comparison of self-employed business owners, independents, and organizational employees.

    PubMed

    Prottas, David J; Thompson, Cynthia A

    2006-10-01

    Using data from the 2002 National Study of the Changing Workforce (NSCW) (N = 3,504), we examined differences among organizational employment and two categories of self-employment: independent contractors and small business owners. Our results suggest that self-employment, either as owner or independent, may allow individuals to achieve greater autonomy than would be available to them as organizational employees. However, the greater pressure associated with ownership of a small business detracts from the advantages of having autonomy, making small business ownership a double-edged sword. Those working as independent contractors appear to reap the benefits of greater autonomy as well as lower levels of job pressure.

  11. Fluid-flow pressure measurements and thermo-fluid characterization of a single loop two-phase passive heat transfer device

    NASA Astrophysics Data System (ADS)

    Ilinca, A.; Mangini, D.; Mameli, M.; Fioriti, D.; Filippeschi, S.; Araneo, L.; Roth, N.; Marengo, M.

    2017-11-01

    A Novel Single Loop Pulsating Heat Pipe (SLPHP), with an inner diameter of 2 mm, filled up with two working fluids (Ethanol and FC-72, Filling Ratio of 60%), is tested in Bottom Heated mode varying the heating power and the orientation. The static confinement diameter for Ethanol and FC-72, respectively 3.4 mm and 1.7mm, is above and slightly under the inner diameter of the tube. This is important for a better understanding of the working principle of the device very close to the limit between the Loop Thermosyphon and Pulsating Heat Pipe working modes. With respect to previous SLPHP experiments found in the literature, such device is designed with two transparent inserts mounted between the evaporator and the condenser allowing direct fluid flow visualization. Two highly accurate pressure transducers permit local pressure measurements just at the edges of one of the transparent inserts. Additionally, three heating elements are controlled independently, so as to vary the heating distribution at the evaporator. It is found that peculiar heating distributions promote the slug/plug flow motion in a preferential direction, increasing the device overall performance. Pressure measurements point out that the pressure drop between the evaporator and the condenser are related to the flow pattern. Furthermore, at high heat inputs, the flow regimes recorded for the two fluids are very similar, stressing that, when the dynamic effects start to play a major role in the system, the device classification between Loop Thermosyphon and Pulsating Heat Pipe is not that sharp anymore.

  12. Design of a Cyclic Pressure Bioreactor for the Ex Vivo Study of Aortic Heart Valves

    PubMed Central

    Schipke, Kimberly J.; Filip To, S. D.; Warnock, James N.

    2011-01-01

    The aortic valve, located between the left ventricle and the aorta, allows for unidirectional blood flow, preventing backflow into the ventricle. Aortic valve leaflets are composed of interstitial cells suspended within an extracellular matrix (ECM) and are lined with an endothelial cell monolayer. The valve withstands a harsh, dynamic environment and is constantly exposed to shear, flexion, tension, and compression. Research has shown calcific lesions in diseased valves occur in areas of high mechanical stress as a result of endothelial disruption or interstitial matrix damage1-3. Hence, it is not surprising that epidemiological studies have shown high blood pressure to be a leading risk factor in the onset of aortic valve disease4. The only treatment option currently available for valve disease is surgical replacement of the diseased valve with a bioprosthetic or mechanical valve5. Improved understanding of valve biology in response to physical stresses would help elucidate the mechanisms of valve pathogenesis. In turn, this could help in the development of non-invasive therapies such as pharmaceutical intervention or prevention. Several bioreactors have been previously developed to study the mechanobiology of native or engineered heart valves6-9. Pulsatile bioreactors have also been developed to study a range of tissues including cartilage10, bone11 and bladder12. The aim of this work was to develop a cyclic pressure system that could be used to elucidate the biological response of aortic valve leaflets to increased pressure loads. The system consisted of an acrylic chamber in which to place samples and produce cyclic pressure, viton diaphragm solenoid valves to control the timing of the pressure cycle, and a computer to control electrical devices. The pressure was monitored using a pressure transducer, and the signal was conditioned using a load cell conditioner. A LabVIEW program regulated the pressure using an analog device to pump compressed air into the

  13. Design of a cyclic pressure bioreactor for the ex vivo study of aortic heart valves.

    PubMed

    Schipke, Kimberly J; To, S D Filip; Warnock, James N

    2011-08-23

    The aortic valve, located between the left ventricle and the aorta, allows for unidirectional blood flow, preventing backflow into the ventricle. Aortic valve leaflets are composed of interstitial cells suspended within an extracellular matrix (ECM) and are lined with an endothelial cell monolayer. The valve withstands a harsh, dynamic environment and is constantly exposed to shear, flexion, tension, and compression. Research has shown calcific lesions in diseased valves occur in areas of high mechanical stress as a result of endothelial disruption or interstitial matrix damage(1-3). Hence, it is not surprising that epidemiological studies have shown high blood pressure to be a leading risk factor in the onset of aortic valve disease(4). The only treatment option currently available for valve disease is surgical replacement of the diseased valve with a bioprosthetic or mechanical valve(5). Improved understanding of valve biology in response to physical stresses would help elucidate the mechanisms of valve pathogenesis. In turn, this could help in the development of non-invasive therapies such as pharmaceutical intervention or prevention. Several bioreactors have been previously developed to study the mechanobiology of native or engineered heart valves(6-9). Pulsatile bioreactors have also been developed to study a range of tissues including cartilage(10), bone(11) and bladder(12). The aim of this work was to develop a cyclic pressure system that could be used to elucidate the biological response of aortic valve leaflets to increased pressure loads. The system consisted of an acrylic chamber in which to place samples and produce cyclic pressure, viton diaphragm solenoid valves to control the timing of the pressure cycle, and a computer to control electrical devices. The pressure was monitored using a pressure transducer, and the signal was conditioned using a load cell conditioner. A LabVIEW program regulated the pressure using an analog device to pump compressed

  14. Social Work and Evaluation: Why You Might Be Interested in the American Evaluation Association Social Work Topical Interest Group

    ERIC Educational Resources Information Center

    Wharton, Tracy C.; Kazi, Mansoor A.

    2012-01-01

    With increased pressure on programs to evaluate outcomes, the issue of evaluation in social work has never been so topical. In response to these pressures, there has been a growing interest in evidence-based practice and strategies for the evaluation of social work programs. The American Evaluation Association (AEA) is an international…

  15. Local Leak Detection and Health Monitoring of Pressurized Tanks

    NASA Technical Reports Server (NTRS)

    Polzin, Kurt; Witherow, William; Korman, Valentin; Sinko, John; Hendrickson, Adam

    2011-01-01

    An optical gas-detection sensor safely monitors pressurized systems (such as cryogenic tanks) and distribution systems for leaks. This sensor system is a fiber-coupled, solid optical body interferometer that allows for the miniaturized sensing element of the device to be placed in the smallest of recesses, and measures a wide range of gas species and densities (leaks). The deflection of the fringe pattern is detected and recorded to yield the time-varying gas density in the gap. This technology can be used by manufacturers or storage facilities with toxic, hazardous, or explosive gases. The approach is to monitor the change in the index of refraction associated with low-level gas leaks into a vacuum environment. The completion of this work will provide NASA with an enabling capability to detect gas system leaks in space, and to verify that pressurized systems are in a safe (i.e. non-leaking) condition during manned docking and transit operations. By recording the output of the sensor, a time-history of the leak can be constructed to indicate its severity. Project risk is mitigated by having several interferometric geometries and detection techniques available, each potentially leveraging hardware and lessons learned to enhance detectability.

  16. Antibodies under pressure: A Small-Angle X-ray Scattering study of Immunoglobulin G under high hydrostatic pressure.

    PubMed

    König, Nico; Paulus, Michael; Julius, Karin; Schulze, Julian; Voetz, Matthias; Tolan, Metin

    2017-12-01

    In the present work two subclasses of the human antibody Immunoglobulin G (IgG) have been investigated by Small-Angle X-ray Scattering under high hydrostatic pressures up to 5kbar. It is shown that IgG adopts a symmetric T-shape in solution which differs significantly from available crystal structures. Moreover, high-pressure experiments verify the high stability of the IgG molecule. It is not unfolded by hydrostatic pressures of up to 5kbar but a slight increase of the radius of gyration was observed at elevated pressures. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. Working cycles of devices based on bistable carbon nanotubes

    NASA Astrophysics Data System (ADS)

    Shklyaev, Oleg; Mockensturm, Eric; Crespi, Vincent; Carbon Nanotubes Collaboration

    2013-03-01

    Shape-changing nanotubes are an example of variable-shape sp2 carbon-based systems where the competition between strain and surface energies can be moderated by an externally controllable stimuli such as applied voltage, temperature, or pressure of gas encapsulated inside the tube. Using any of these stimuli one can transition a bistable carbon nanotube between the collapsed and inflated states and thus perform mechanical work. During the working cycle of such a device, energy from an electric or heat source is transferred to mechanical energy. Combinations of these stimuli allow the system to convert energy between different sources using the bistable shape-changing tube as a mediator. For example, coupling a bistable carbon nanotube to the heat and charge reservoirs can enable energy transfer between heat and electric forms. The developed theory can be extended to other nano-systems which change configurations in response to external stimuli.

  18. Creating Binary Cu–Bi Compounds via High-Pressure Synthesis: A Combined Experimental and Theoretical Study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Clarke, Samantha M.; Amsler, Maximilian; Walsh, James P. S.

    Exploration beyond the known phase space of thermodynamically stable compounds into the realm of metastable materials is a frontier of materials chemistry. The application of high pressure in experiment and theory provides a powerful vector by which to explore this uncharted phase space, allowing discovery of complex new structures and bonding in the solid state. We harnessed this approach for the Cu–Bi system, where the realization of new phases offers potential for exotic properties such as superconductivity. This potential is due to the presence of bismuth, which, by virtue of its status as one of the heaviest stable elements, formsmore » a critical component in emergent materials such as superconductors and topological insulators. To fully investigate and understand the Cu–Bi system, we welded theoretical predictions with experiment to probe the Cu–Bi system under high pressures. By employing the powerful approach of in situ X-ray diffraction in a laser-heated diamond anvil cell (LHDAC), we thoroughly explored the high-pressure and high-temperature (high-PT) phase space to gain insight into the formation of intermetallic compounds at these conditions. We employed density functional theory (DFT) calculations to calculate a pressure versus temperature phase diagram, which correctly predicts that CuBi is stabilized at lower pressures than Cu11Bi7, and allows us to uncover the thermodynamic contributions responsible for the stability of each phase. Detailed comparisons between the NiAs structure type and the two high-pressure Cu–Bi phases, Cu11Bi7 and CuBi, reveal the preference for elemental segregation within the Cu–Bi phases, and highlight the unique channels and layers formed by ordered Cu vacancies. The electron localization function from DFT calculations account for the presence of these “voids” as a manifestation of the lone pair orientation on the Bi atoms. Our study demonstrates the power of joint experimental–computational work in

  19. Report on ISS O2 Production, Gas Supply and Partial Pressure Management

    NASA Technical Reports Server (NTRS)

    Schaezler, Ryan N.; Cook, Anthony J.

    2015-01-01

    Oxygen is used on International Space Station (ISS) for metabolic support and denitrogenation procedures prior to Extra-Vehicular Activities. Nitrogen is used to maintain total pressure and account for losses associated with leakage and operational losses. Oxygen and nitrogen have been supplied by various visiting vehicles such as the Progress and Shuttle in addition to the on-orbit oxygen production capability. Starting in 2014, new high pressure oxygen/nitrogen tanks are available to launch on commercial cargo vehicles and will replace the high pressure gas source that Shuttle used to provide. To maintain a habitable atmosphere the oxygen and nitrogen partial pressures are controlled between upper and lower bounds. The full range of the allowable partial pressures along with the increased ISS cabin volume are utilized as a buffer allowing days to pass between oxygen production or direct addition of oxygen and nitrogen to the atmosphere from reserves. This paper summarizes the amount of gas supplied and produced from all of the sources and describes past experience of managing partial pressures along with the range of management options available to the ISS.

  20. Flexible suspended gate organic thin-film transistors for ultra-sensitive pressure detection

    PubMed Central

    Zang, Yaping; Zhang, Fengjiao; Huang, Dazhen; Gao, Xike; Di, Chong-an; Zhu, Daoben

    2015-01-01

    The utilization of organic devices as pressure-sensing elements in artificial intelligence and healthcare applications represents a fascinating opportunity for the next-generation electronic products. To satisfy the critical requirements of these promising applications, the low-cost construction of large-area ultra-sensitive organic pressure devices with outstanding flexibility is highly desired. Here we present flexible suspended gate organic thin-film transistors (SGOTFTs) as a model platform that enables ultra-sensitive pressure detection. More importantly, the unique device geometry of SGOTFTs allows the fine-tuning of their sensitivity by the suspended gate. An unprecedented sensitivity of 192 kPa−1, a low limit-of-detection pressure of <0.5 Pa and a short response time of 10 ms were successfully realized, allowing the real-time detection of acoustic waves. These excellent sensing properties of SGOTFTs, together with their advantages of facile large-area fabrication and versatility in detecting various pressure signals, make SGOTFTs a powerful strategy for spatial pressure mapping in practical applications. PMID:25872157

  1. Gas network model allows full reservoir coupling

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Methnani, M.M.

    The gas-network flow model (Gasnet) developed for and added to an existing Qatar General Petroleum Corp. (OGPC) in-house reservoir simulator, allows improved modeling of the interaction among the reservoir, wells, and pipeline networks. Gasnet is a three-phase model that is modified to handle gas-condensate systems. The numerical solution is based on a control volume scheme that uses the concept of cells and junctions, whereby pressure and phase densities are defined in cells, while phase flows are defined at junction links. The model features common numerical equations for the reservoir, the well, and the pipeline components and an efficient state-variable solutionmore » method in which all primary variables including phase flows are solved directly. Both steady-state and transient flow events can be simulated with the same tool. Three test cases show how the model runs. One case simulates flow redistribution in a simple two-branch gas network. The second simulates a horizontal gas well in a waterflooded gas reservoir. The third involves an export gas pipeline coupled to a producing reservoir.« less

  2. Gunslingers, poker players, and chickens 1: Decision making under physical performance pressure in elite athletes.

    PubMed

    Parkin, Beth L; Warriner, Katie; Walsh, Vincent

    2017-01-01

    The cognitive skills required during sport are highly demanding; accurate decisions based on the processing of dynamic environments are made in a fraction of a second (Walsh, 2014). Optimal decision-making abilities are crucial for success in sporting competition (Bar-Eli et al., 2011; Kaya, 2014). Moreover, for the elite athlete, decision making is required under conditions of intense mental and physical pressure (Anshel and Wells, 2000), yet much of the work in this area has largely ignored the highly stressful context in which athletes operate. A number of studies have shown that conditions of elevated pressure influence athletes' decision quality (Kinrade et al., 2015; Smith et al., 2016), response times (Hepler, 2015; Smith et al., 2016) and risk taking (Pighin et al., 2015). However, almost all of this work has been undertaken in nonelite athletes and participants who do not routinely operate under conditions of high stress. Thus, there is very little known about the influence of pressure on decision making in elite athletes. This study investigated the influence of physical performance pressure on decision making in a sample of world-class elite athletes. This allowed an examination of whether findings from the previous work in nonelite athletes extend to those who routinely operate under conditions of high stress. How this work could be applied to improve insight and understanding of decision making among sport professionals is examined. We sought to introduce a categorization of decision making useful to practitioners in sport: gunslingers, poker players, and chickens. Twenty-three elite athletes who compete and have frequent success at an international level (including six Olympic medal winners) performed tasks relating to three categories of decision making under conditions of low and high physical pressure. Decision making under risk was measured with performance on the Cambridge Gambling Task (CGT; Rogers et al., 1999), decision making under

  3. Back to Work

    ERIC Educational Resources Information Center

    Fernandez, Kim

    2010-01-01

    The economic downturn hit working America particularly hard, as agricultural, automotive, manufacturing, and retail jobs in many corners of the country all but evaporated. Consumers continue to cut back, and jobless rates in many states have eclipsed levels not seen in decades. Out of work and under pressure, many Americans are turning to the…

  4. Numerical system for monitoring pressurized equipment

    NASA Astrophysics Data System (ADS)

    Dobra, Remus; Pasculescu, Dragos; Boca, Maria Loredana; Moldovan, Lucian

    2016-12-01

    Electrical devices for operation in potentially explosive atmospheres are designed and built in accordance with European standard EN 50015: 1995 ex. the pressurized enclosure "p". The type of protector p, by using a protective gas in the housing is intended to prevent the formation of an explosive atmosphere within it, while maintaining an overpressure to the surrounding atmosphere and, where appropriate, by the use dilution. Research conducted for pressurized encapsulation aimed at developing new procedures for determining the parameters of pressurization to allow safe use of electrical appliances. Pressurization with compensation for losses allegedly maintaining overpressure inside the enclosure when the outlets are closed, is made by feeding protective gas in an amount sufficient to fully compensate for losses from the housing inevitable pressurized and its associated pipework. The conditions and necessary measures that are required for appliances and equipment with potential ignition of explosive atmospheres are detailed in the SR EN 50016/2000. For pressurized encapsulation protection mode, the electric equipment can be maintained safety by the overpressure created inside them and in the supply pipes with air. The paper presents a modern method to determine the parameters of the electric equipment with pressurization enclosures. For controlling of such equipment, a specific algorithm has been developed and laboratory tested.

  5. Hypothesis: the regulation of the partial pressure of oxygen by the serotonergic nervous system in hypoxia.

    PubMed

    Devereux, Diana; Ikomi-Kumm, Julie

    2013-03-01

    The regulation of the partial pressure of oxygen by the serotonergic nervous system in hypoxia is a hypothesis, which proposes an inherent operative system in homo sapiens that allows central nervous system and endocrine-mediated vascular system adaption to variables in partial pressure of oxygen, pH and body composition, while maintaining sufficient oxygen saturation for the immune system and ensuring protection of major organs in hypoxic and suboptimal conditions. While acknowledging the importance of the Henderson-Hasselbalch equation in the regulation of acid base balance, the hypothesis seeks to define the specific neuroendocrine/vascular mechanisms at work in regulating acid base balance in hypoxia and infection. The SIA (serotonin-immune-adrenergic) system is proposed as a working model, which allows central nervous system and endocrine-mediated macro- and micro vascular 'fine tuning'. The neurotransmitter serotonin serves as a 'hypoxic sensor' in concert with other operators to orchestrate homeostatic balance in normal and pathological states. The SIA system finely regulates oxygen, fuel and metabolic buffering systems at local sites to ensure optimum conditions for the immune response. The SIA system is fragile and its operation may be affected by infection, stress, diet, environmental toxins and lack of exercise. The hypothesis provides new insight in the area of neuro-gastroenterology, and emphasizes the importance of diet and nutrition as a complement in the treatment of infection, as well as the normalization of intestinal flora following antibiotic therapy. Copyright © 2012 Elsevier Ltd. All rights reserved.

  6. TDM Status Report: Transportation Allowances

    DOT National Transportation Integrated Search

    1992-08-01

    The status report discusses the following travel allowance programs that provide subsidies to employees in one form or another: transit fare allowances or subsidies; vanpool fare allowances; parking allowances or free parking; and general travel allo...

  7. Making synthetic mudstone: Parametric resedimentation studies at high effective stress to determine controls on breakthrough pressure and permeability

    NASA Astrophysics Data System (ADS)

    Guiltinan, E. J.; Cardenas, M. B.; Cockrell, L.; Espinoza, N.

    2017-12-01

    The geologic sequestration of CO2 is widely considered a potential solution for decreasing anthropogenic atmospheric CO2 emissions. As CO2 rises buoyantly within a reservoir it pools beneath a caprock and a pressure is exerted upon the pores of the caprock proportionally to the height of the pool. The breakthrough pressure is the point at which CO2 begins to flow freely across the caprock. Understanding the mineralogical and grain size controls on breakthrough pressure is important for screening the security of CO2 sequestration sites. However, breakthrough pressure and permeability measurements on caprocks are difficult to conduct in a systematic manner given the variability in and heterogeneity of naturally occurring mudstones and shales causing significant noise and scatter in the literature. Recent work has even revealed the ability for CO2 to pass through thin shale beds at relatively low pressures. To broaden the understanding of shale breakthrough and permeability, we developed an approach that allows for the creation of resedimented mudstones at high effective stresses. Resedimented samples also include calcium carbonate cement. Using this technique, we explore the controls on entry pressure, breakthrough pressure, and permeability of synthetic mudstones. Understanding the effect of mineralogy and grain size on the permeability and breakthrough pressure of mudstones at reservoir stresses will help in the selection and uncertainty quantification of secure CO2 storage sites.

  8. 34 CFR 694.23 - What additional activities are allowable for State GEAR UP projects?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... associate's or a bachelor's degree), including school designs that give students early exposure to college-level courses and experiences and allow students to earn transferable college credits or an associate's... allow drop-outs to complete a secondary school diploma and begin college-level work. (Authority: 20 U.S...

  9. 34 CFR 694.23 - What additional activities are allowable for State GEAR UP projects?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... associate's or a bachelor's degree), including school designs that give students early exposure to college-level courses and experiences and allow students to earn transferable college credits or an associate's... allow drop-outs to complete a secondary school diploma and begin college-level work. (Authority: 20 U.S...

  10. 34 CFR 694.23 - What additional activities are allowable for State GEAR UP projects?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... associate's or a bachelor's degree), including school designs that give students early exposure to college-level courses and experiences and allow students to earn transferable college credits or an associate's... allow drop-outs to complete a secondary school diploma and begin college-level work. (Authority: 20 U.S...

  11. Continuous positive airway pressure machines and the work of coordinating technologies at home.

    PubMed

    Moreira, Tiago

    2008-06-01

    Research on the use of health technology at home has consistently reported that it is underpinned by users' evaluations of the technology in relation to their illness trajectory, their social network, and the place where it is used. Recent studies have also revealed that the efficacy of health technologies depends upon users' work that is largely invisible to professionals, managers and designers. This paper draws on the most widely used therapy for the management of sleep apnoea, continuous positive airway pressure (CPAP), to show how users maintain workable relationships between it and other technological elements of the domestic environment. Qualitative analysis was performed of an archive of messages sent to a web-based support group for sleep disorders between 1994 and 2007. Users describe two related techniques: first, drawing on their embodied knowledge of using domestic technologies to imagine potential, alternative environments for CPAP; and second, using their body as an instrument to assess the ;fit' of each of the attempted arrangements. The interaction between these two techniques entails frequent shifts in users' understandings of their illness and those involved in its management. Strategies of implementation of health technologies at home should acknowledge and incorporate the embodied knowledge processes of users.

  12. Automated control of endotracheal tube cuff pressure during simulated flight.

    PubMed

    Blakeman, Thomas; Rodriquez, Dario; Woods, James; Cox, Daniel; Elterman, Joel; Branson, Richard

    2016-11-01

    Successful mechanical ventilation requires that the airway be controlled by an endotracheal tube (ETT) with an inflatable cuff to seal the airway. Aeromedical evacuation represents a unique challenge in which to manage ETT cuffs. We evaluated three methods of automatic ETT cuff pressure adjustment during changes in altitude in an altitude chamber. Size 7.5 and 8.0 mm ETTs that are currently included in the Critical Care Air Transport Team allowance standard were used for the evaluation. Three automatic cuff pressure controllers-Intellicuff, Hamilton Medical; Pyton, ARM Medical; and Cuff Sentry, Outcome Solutions-were used to manage cuff pressures. The fourth group had cuff pressure set at sea level without further adjustment. Each ETT was inserted into a tracheal model and taken to 8,000 feet and then to 16,000 feet at 2,500 ft/min. Baseline cuff pressure at sea level was approximately 25 cm H2O. Mean cuff pressure at both altitudes with both size ETTs was as follows: Control arm, 141 ± 64 cm H2O; Pyton, 25 ± 0.8 cm H2O; Cuff Sentry, 22 ± 0.3 cm H2O; and Intellicuff, 29 ± 6.6 cm H2O. The mean time that cuff pressure was >30 cm H2O using Intellicuff at both altitudes was 2.8 ± 0.8 minutes. Pressure differences from baseline in the control arm and with Intellicuff were statistically significant. Cuff pressure with the Cuff Sentry tended to be lower than indicated on the device. Mean cuff pressures were within the recommended range with all three devices. Intellicuff had difficulty regulating the cuff pressure initially with increases in altitude but was able to reduce the pressure to a safe level during the stabilization period at each altitude. The Pyton and Cuff Sentry allowed the least variation in pressure throughout the evaluation, although the Cuff Sentry set pressure was less than the actual pressure. Therapeutic study, level V.

  13. Compensating for pneumatic distortion in pressure sensing devices

    NASA Technical Reports Server (NTRS)

    Whitmore, Stephen A.; Leondes, Cornelius T.

    1990-01-01

    A technique of compensating for pneumatic distortion in pressure sensing devices was developed and verified. This compensation allows conventional pressure sensing technology to obtain improved unsteady pressure measurements. Pressure distortion caused by frictional attenuation and pneumatic resonance within the sensing system makes obtaining unsteady pressure measurements by conventional sensors difficult. Most distortion occurs within the pneumatic tubing which transmits pressure impulses from the aircraft's surface to the measurement transducer. To avoid pneumatic distortion, experiment designers mount the pressure sensor at the surface of the aircraft, (called in-situ mounting). In-situ transducers cannot always fit in the available space and sometimes pneumatic tubing must be run from the aircraft's surface to the pressure transducer. A technique to measure unsteady pressure data using conventional pressure sensing technology was developed. A pneumatic distortion model is reduced to a low-order, state-variable model retaining most of the dynamic characteristics of the full model. The reduced-order model is coupled with results from minimum variance estimation theory to develop an algorithm to compensate for the effects of pneumatic distortion. Both postflight and real-time algorithms are developed and evaluated using simulated and flight data.

  14. Device for testing closure disks at high rates of change of pressure

    DOEpatents

    Merten, Jr., Charles W.

    1993-11-09

    A device for testing the burst pressure of closure disks which provides high pressure to both sides of a disk and rapidly releases pressure from one side thereof causing a high rate of change of pressure. A hollow notched plug allows the rapid release of pressure upon rupturing. A means is also disclosed for transmitting a tensile load from a piston to a hollow notched plug and for sealing the means for transmitting load within a hole in a piston.

  15. Embedding Piezoresistive Pressure Sensors to Obtain Online Pressure Profiles Inside Fiber Composite Laminates

    PubMed Central

    Kahali Moghaddam, Maryam; Breede, Arne; Brauner, Christian; Lang, Walter

    2015-01-01

    The production of large and complex parts using fiber composite materials is costly due to the frequent formation of voids, porosity and waste products. By embedding different types of sensors and monitoring the process in real time, the amount of wastage can be significantly reduced. This work focuses on developing a knowledge-based method to improve and ensure complete impregnation of the fibers before initiation of the resin cure. Piezoresistive and capacitive pressure sensors were embedded in fiber composite laminates to measure the real-time the pressure values inside the laminate. A change of pressure indicates resin infusion. The sensors were placed in the laminate and the resin was infused by vacuum. The embedded piezoresistive pressure sensors were able to track the vacuum pressure in the fiber composite laminate setup, as well as the arrival of the resin at the sensor. The pressure increase due to closing the resin inlet was also measured. In contrast, the capacitive type of sensor was found to be inappropriate for measuring these quantities. The following study demonstrates real-time monitoring of pressure changes inside the fiber composite laminate, which validate the use of Darcy’s law in porous media to control the resin flow during infusion. PMID:25825973

  16. Embedding piezoresistive pressure sensors to obtain online pressure profiles inside fiber composite laminates.

    PubMed

    Moghaddam, Maryam Kahali; Breede, Arne; Brauner, Christian; Lang, Walter

    2015-03-27

    The production of large and complex parts using fiber composite materials is costly due to the frequent formation of voids, porosity and waste products. By embedding different types of sensors and monitoring the process in real time, the amount of wastage can be significantly reduced. This work focuses on developing a knowledge-based method to improve and ensure complete impregnation of the fibers before initiation of the resin cure. Piezoresistive and capacitive pressure sensors were embedded in fiber composite laminates to measure the real-time the pressure values inside the laminate. A change of pressure indicates resin infusion. The sensors were placed in the laminate and the resin was infused by vacuum. The embedded piezoresistive pressure sensors were able to track the vacuum pressure in the fiber composite laminate setup, as well as the arrival of the resin at the sensor. The pressure increase due to closing the resin inlet was also measured. In contrast, the capacitive type of sensor was found to be inappropriate for measuring these quantities. The following study demonstrates real-time monitoring of pressure changes inside the fiber composite laminate, which validate the use of Darcy's law in porous media to control the resin flow during infusion.

  17. On Time Performance Pressure

    NASA Technical Reports Server (NTRS)

    Connell, Linda; Wichner, David; Jakey, Abegael

    2013-01-01

    Within many operations, the pressures for on-time performance are high. Each month, on-time statistics are reported to the Department of Transportation and made public. There is a natural tendency for employees under pressure to do their best to meet these objectives. As a result, pressure to get the job done within the allotted time may cause personnel to deviate from procedures and policies. Additionally, inadequate or unavailable resources may drive employees to work around standard processes that are seen as barriers. However, bypassing practices to enable on-time performance may affect more than the statistics. ASRS reports often highlight on-time performance pressures which may result in impact across all workgroups in an attempt to achieve on-time performance. Reporters often provide in-depth insights into their experiences which can be used by industry to identify and focus on the implementation of systemic fixes.

  18. Pressure sensitive microparticle adhesion through biomimicry of the pollen-stigma interaction.

    PubMed

    Lin, Haisheng; Qu, Zihao; Meredith, J Carson

    2016-03-21

    Many soft biomimetic synthetic adhesives, optimized to support macroscopic masses (∼kg), have been inspired by geckos, insects and other animals. Far less work has investigated bioinspired adhesion that is tuned to micro- and nano-scale sizes and forces. However, such adhesive forces are extremely important in the adhesion of micro- and nanoparticles to surfaces, relevant to a wide range of industrial and biological systems. Pollens, whose adhesion is critical to plant reproduction, are an evolutionary-optimized system for biomimicry to engineer tunable adhesion between particles and micro-patterned soft matter surfaces. In addition, the adhesion of pollen particles is relevant to topics as varied as pollinator ecology, transport of allergens, and atmospheric phenomena. We report the first observation of structurally-derived pressure-sensitive adhesion of a microparticle by using the sunflower pollen and stigma surfaces as a model. This strong, pressure-sensitive adhesion results from interlocking between the pollen's conical spines and the stigma's receptive papillae. Inspired by this behavior, we fabricated synthetic polymeric patterned surfaces that mimic the stigma surface's receptivity to pollen. These soft mimics allow the magnitude of the pressure-sensitive response to be tuned by adjusting the size and spacing of surface features. These results provide an important new insight for soft material adhesion based on bio-inspired principles, namely that ornamented microparticles and micro-patterned surfaces can be designed with complementarity that enable a tunable, pressure-sensitive adhesion on the microparticle size and length scale.

  19. In-shoe plantar pressure measurement and analysis system based on fabric pressure sensing array.

    PubMed

    Shu, Lin; Hua, Tao; Wang, Yangyong; Qiao Li, Qiao; Feng, David Dagan; Tao, Xiaoming

    2010-05-01

    Spatial and temporal plantar pressure distributions are important and useful measures in footwear evaluation, athletic training, clinical gait analysis, and pathology foot diagnosis. However, present plantar pressure measurement and analysis systems are more or less uncomfortable to wear and expensive. This paper presents an in-shoe plantar pressure measurement and analysis system based on a textile fabric sensor array, which is soft, light, and has a high-pressure sensitivity and a long service life. The sensors are connected with a soft polymeric board through conductive yarns and integrated into an insole. A stable data acquisition system interfaces with the insole, wirelessly transmits the acquired data to remote receiver through Bluetooth path. Three configuration modes are incorporated to gain connection with desktop, laptop, or smart phone, which can be configured to comfortably work in research laboratories, clinics, sport ground, and other outdoor environments. A real-time display and analysis software is presented to calculate parameters such as mean pressure, peak pressure, center of pressure (COP), and shift speed of COP. Experimental results show that this system has stable performance in both static and dynamic measurements.

  20. Magnetically Delayed Low-Pressure Gas Discharge Switching

    DTIC Science & Technology

    1993-06-01

    the gap, minimizes this effect. It is this version of the low- pressure switch that we are presently studying. Our magnetically delayed low... pressure switch (MDLPS) test-stand was built primarily to support the long-pulse, relativistic klystron (RK) and free electron laser (FEL) work at... pressure switch and compared the performance with and without the saturable inductor. A comparison of typi- cal closure properties is shown in Fig

  1. High pressure inactivation of relevant target microorganisms in poultry meat products and the evaluation of pressure-induced protein denaturation of marinated poultry under different high pressure treatments

    NASA Astrophysics Data System (ADS)

    Schmidgall, Johanna; Hertel, Christian; Bindrich, Ute; Heinz, Volker; Toepfl, Stefan

    2011-03-01

    In this study, the possibility of extending shelf life of marinated poultry meat products by high pressure processing was evaluated. Relevant spoilage and pathogenic strains were selected and used as target microorganisms (MOs) for challenge experiments. Meat and brine were inoculated with MOs and treated at 450 MPa, 4 °C for 3 min. The results of inactivation show a decreasing pressure tolerance in the series Lactobacillus > Arcobacter > Carnobacterium > Bacillus cereus > Brochothrix thermosphacta > Listeria monocytogenes. Leuconostoc gelidum exhibited the highest pressure tolerance in meat. A protective effect of poultry meat was found for L. sakei and L. gelidum. In parallel, the influence of different marinade formulations (pH, carbonates, citrates) on protein structure changes during a pressure treatment was investigated. Addition of sodium carbonate shows a protection against denaturation of myofibrillar proteins and provides a maximum water-holding capacity. Caustic marinades allowed a higher retention of product characteristics than low-pH marinades.

  2. Optical surface pressure measurements: Accuracy and application field evaluation

    NASA Astrophysics Data System (ADS)

    Bukov, A.; Mosharov, V.; Orlov, A.; Pesetsky, V.; Radchenko, V.; Phonov, S.; Matyash, S.; Kuzmin, M.; Sadovskii, N.

    1994-07-01

    Optical pressure measurement (OPM) is a new pressure measurement method rapidly developed in several aerodynamic research centers: TsAGI (Russia), Boeing, NASA, McDonnell Douglas (all USA), and DLR (Germany). Present level of OPM-method provides its practice as standard experimental method of aerodynamic investigations in definite application fields. Applications of OPM-method are determined mainly by its accuracy. The accuracy of OPM-method is determined by the errors of three following groups: (1) errors of the luminescent pressure sensor (LPS) itself, such as uncompensated temperature influence, photo degradation, temperature and pressure hysteresis, variation of the LPS parameters from point to point on the model surface, etc.; (2) errors of the measurement system, such as noise of the photodetector, nonlinearity and nonuniformity of the photodetector, time and temperature offsets, etc.; and (3) methodological errors, owing to displacement and deformation of the model in an airflow, a contamination of the model surface, scattering of the excitation and luminescent light from the model surface and test section walls, etc. OPM-method allows getting total error of measured pressure not less than 1 percent. This accuracy is enough to visualize the pressure field and allows determining total and distributed aerodynamic loads and solving some problems of local aerodynamic investigations at transonic and supersonic velocities. OPM is less effective at low subsonic velocities (M less than 0.4), and for precise measurements, for example, an airfoil optimization. Current limitations of the OPM-method are discussed on an example of the surface pressure measurements and calculations of the integral loads on the wings of canard-aircraft model. The pressure measurement system and data reduction methods used on these tests are also described.

  3. Rankine cycle condenser pressure control using an energy conversion device bypass valve

    DOEpatents

    Ernst, Timothy C; Nelson, Christopher R; Zigan, James A

    2014-04-01

    The disclosure provides a waste heat recovery system and method in which pressure in a Rankine cycle (RC) system of the WHR system is regulated by diverting working fluid from entering an inlet of an energy conversion device of the RC system. In the system, an inlet of a controllable bypass valve is fluidly coupled to a working fluid path upstream of an energy conversion device of the RC system, and an outlet of the bypass valve is fluidly coupled to the working fluid path upstream of the condenser of the RC system such that working fluid passing through the bypass valve bypasses the energy conversion device and increases the pressure in a condenser. A controller determines the temperature and pressure of the working fluid and controls the bypass valve to regulate pressure in the condenser.

  4. Inertial motion capture system for biomechanical analysis in pressure suits

    NASA Astrophysics Data System (ADS)

    Di Capua, Massimiliano

    A non-invasive system has been developed at the University of Maryland Space System Laboratory with the goal of providing a new capability for quantifying the motion of the human inside a space suit. Based on an array of six microprocessors and eighteen microelectromechanical (MEMS) inertial measurement units (IMUs), the Body Pose Measurement System (BPMS) allows the monitoring of the kinematics of the suit occupant in an unobtrusive, self-contained, lightweight and compact fashion, without requiring any external equipment such as those necessary with modern optical motion capture systems. BPMS measures and stores the accelerations, angular rates and magnetic fields acting upon each IMU, which are mounted on the head, torso, and each segment of each limb. In order to convert the raw data into a more useful form, such as a set of body segment angles quantifying pose and motion, a series of geometrical models and a non-linear complimentary filter were implemented. The first portion of this works focuses on assessing system performance, which was measured by comparing the BPMS filtered data against rigid body angles measured through an external VICON optical motion capture system. This type of system is the industry standard, and is used here for independent measurement of body pose angles. By comparing the two sets of data, performance metrics such as BPMS system operational conditions, accuracy, and drift were evaluated and correlated against VICON data. After the system and models were verified and their capabilities and limitations assessed, a series of pressure suit evaluations were conducted. Three different pressure suits were used to identify the relationship between usable range of motion and internal suit pressure. In addition to addressing range of motion, a series of exploration tasks were also performed, recorded, and analysed in order to identify different motion patterns and trajectories as suit pressure is increased and overall suit mobility is reduced

  5. Methodology and technology for peripheral and central blood pressure and blood pressure variability measurement: current status and future directions - Position statement of the European Society of Hypertension Working Group on blood pressure monitoring and cardiovascular variability.

    PubMed

    Stergiou, George S; Parati, Gianfranco; Vlachopoulos, Charalambos; Achimastos, Apostolos; Andreadis, Emanouel; Asmar, Roland; Avolio, Alberto; Benetos, Athanase; Bilo, Grzegorz; Boubouchairopoulou, Nadia; Boutouyrie, Pierre; Castiglioni, Paolo; de la Sierra, Alejandro; Dolan, Eamon; Head, Geoffrey; Imai, Yutaka; Kario, Kazuomi; Kollias, Anastasios; Kotsis, Vasilis; Manios, Efstathios; McManus, Richard; Mengden, Thomas; Mihailidou, Anastasia; Myers, Martin; Niiranen, Teemu; Ochoa, Juan Eugenio; Ohkubo, Takayoshi; Omboni, Stefano; Padfield, Paul; Palatini, Paolo; Papaioannou, Theodore; Protogerou, Athanasios; Redon, Josep; Verdecchia, Paolo; Wang, Jiguang; Zanchetti, Alberto; Mancia, Giuseppe; O'Brien, Eoin

    2016-09-01

    Office blood pressure measurement has been the basis for hypertension evaluation for almost a century. However, the evaluation of blood pressure out of the office using ambulatory or self-home monitoring is now strongly recommended for the accurate diagnosis in many, if not all, cases with suspected hypertension. Moreover, there is evidence that the variability of blood pressure might offer prognostic information that is independent of the average blood pressure level. Recently, advancement in technology has provided noninvasive evaluation of central (aortic) blood pressure, which might have attributes that are additive to the conventional brachial blood pressure measurement. This position statement, developed by international experts, deals with key research and practical issues in regard to peripheral blood pressure measurement (office, home, and ambulatory), blood pressure variability, and central blood pressure measurement. The objective is to present current achievements, identify gaps in knowledge and issues concerning clinical application, and present relevant research questions and directions to investigators and manufacturers for future research and development (primary goal).

  6. Report on ISS Oxygen Production, Resupply, and Partial Pressure Management

    NASA Technical Reports Server (NTRS)

    Schaezler, Ryan; Ghariani, Ahmed; Leonard, Daniel; Lehman, Daniel

    2011-01-01

    The majority of oxygen used on International Space Station (ISS) is for metabolic support and denitrogenation procedures prior to Extra-Vehicular Activities. Oxygen is supplied by various visiting vehicles such as the Progress and Shuttle in addition to oxygen production capability on both the United States On-Orbit Segment (USOS) and Russian Segment (RS). To maintain a habitable atmosphere the oxygen partial pressure is controlled between upper and lower bounds. The full range of the allowable oxygen partial pressure along with the increased ISS cabin volume is utilized as a buffer allowing days to pass between oxygen production or direct addition of oxygen to the atmosphere from reserves. This paper summarizes amount of oxygen supplied and produced from all of the sources and describes past experience of managing oxygen partial pressure along with the range of management options available to the ISS.

  7. Low pressure versus standard pressure pneumoperitoneum in laparoscopic cholecystectomy.

    PubMed

    Gurusamy, Kurinchi Selvan; Vaughan, Jessica; Davidson, Brian R

    2014-03-18

    ; 394 participants; RR 3.00; 95% CI 0.14 to 65.90; very low quality evidence). Quality of life, return to normal activity, and return to work were not reported in any of the trials. The difference between groups in the conversion to open cholecystectomy was imprecise (low pressure group 2/269, adjusted proportion 0.8%; standard pressure group 2/287, 0.7%; 10 trials; 556 participants; RR 1.18; 95% CI 0.29 to 4.72; very low quality evidence) and was compatible with an increase, a decrease, or no difference in the proportion of conversion to open cholecystectomy due to low pressure pneumoperitoneum. No difference in the length of hospital stay was reported between the groups (five trials; 415 participants; MD -0.30 days; 95% CI -0.63 to 0.02; low quality evidence). Operating time was about two minutes longer in the low pressure group than in the standard pressure group (19 trials; 990 participants; MD 1.51 minutes; 95% CI 0.07 to 2.94; very low quality evidence). Laparoscopic cholecystectomy can be completed successfully using low pressure in approximately 90% of people undergoing laparoscopic cholecystectomy. However, no evidence is currently available to support the use of low pressure pneumoperitoneum in low anaesthetic risk patients undergoing elective laparoscopic cholecystectomy. The safety of low pressure pneumoperitoneum has to be established. Further well-designed trials are necessary, particularly in people with cardiopulmonary disorders who undergo laparoscopic cholecystectomy.

  8. Influence of lifestyle, coping, and job stress on blood pressure in men and women.

    PubMed

    Lindquist, T L; Beilin, L J; Knuiman, M W

    1997-01-01

    We designed this study to clarify the role of work stress on long-term blood pressure control and in particular to investigate whether perceived work stress directly affected resting blood pressure levels or whether there were indirect effects mediated by coping mechanisms and lifestyle. Men (n = 337) and women (n = 317) working in a government tax office completed questionnaires for assessment of work-related stress, coping strategies, and lifestyle. Seven resting blood pressure measurements were recorded serially on each of two occasions a week apart. Men had higher blood pressures (119.6/68.6 versus 110.9/65.6 mm Hg) than women; they used more "maladaptive" coping strategies, drank more alcohol, and ate less healthily but exercised more than women. There were no direct associations between measures of work stress and blood pressure. In univariate and regression analyses, both body mass index and lifestyle factors in the form of alcohol consumption, exercise, and diet were related to blood pressure in men and women. Various "adaptive" or "maladaptive" coping mechanisms were identified and independently related to both job stress and blood pressure levels. Women were more likely to use "healthier" or adaptive coping mechanisms than men. Thus, work stress per se had no direct effect on blood pressure, but the ways that individuals reported coping with stress were significantly related to blood pressure, with blood pressure elevation effects appearing to be mediated largely by dietary and drinking habits and physical inactivity. The results point to the need to target individual coping strategies and lifestyle as much as the working environment in workplace cardiovascular health promotion programs.

  9. Zeeman Effect in Ruby at High Pressures

    NASA Astrophysics Data System (ADS)

    Dan, Ioana

    2012-02-01

    We have developed a versatile fiber-coupled system for magneto-optical spectroscopy measurements at high pressure. The system is based on a miniature Cu-alloy Diamond Anvil Cell (from D'Anvils, Ltd) fitted with a custom-designed He gas-actuated membrane for in-situ pressure control, and coupled with a He transfer cryostat incorporating a superconducting magnet (from Quantum Designs). This system allows optical measurements (Raman, photoluminescence, reflectivity) within wide ranges of pressures (up to 100GPa), temperatures (4.2-300K) and magnetic fields (0-9T). We employ this system to examine the effect of pressure and non-hydrostatic stress on the Zeeman split d-d transitions of Cr^3+ in ruby (Al2O3: Cr^3+). We determine the effect of pressure and non-hydrostaticity on the trigonal crystal field in this material, and discuss the use of the Zeman-split ruby fluorescence as a possible probe for deviatoric stresses in diamond anvil cell experiments.

  10. Intradiscal pressure variation under spontaneous ventilation

    NASA Astrophysics Data System (ADS)

    Roriz, Paulo; Ferreira, J.; Potes, J. C.; Oliveira, M. T.; Santos, J. L.; Simões, J. A.; Frazão, O.

    2014-05-01

    The pressure measured in the intervertebral discs is a response to the loads acting on the spine. External loads, such as the reaction forces resulting from locomotion, manual handling and collisions are probably the most relevant in studying spine trauma. However, the physiological functions such as breathing and hearth rate also participate in subtle variations of intradiscal pressure that can be observed only in vivo at resting. Present work is an effort to measure the effect of breathing on intradiscal pressure of an anesthetized sheep.

  11. Development of uniform standards for allowable lane closure : final report, September 2008.

    DOT National Transportation Integrated Search

    2008-09-01

    Procedures for determining allowable lane closure hours to perform maintenance, construction, resurfacing, regional permit and major access permit work on the state highway system were evaluated. The current process involves the collection of traffic...

  12. A System for Incubations at High Gas Partial Pressure

    PubMed Central

    Sauer, Patrick; Glombitza, Clemens; Kallmeyer, Jens

    2012-01-01

    High-pressure is a key feature of deep subsurface environments. High partial pressure of dissolved gasses plays an important role in microbial metabolism, because thermodynamic feasibility of many reactions depends on the concentration of reactants. For gases, this is controlled by their partial pressure, which can exceed 1 MPa at in situ conditions. Therefore, high hydrostatic pressure alone is not sufficient to recreate true deep subsurface in situ conditions, but the partial pressure of dissolved gasses has to be controlled as well. We developed an incubation system that allows for incubations at hydrostatic pressure up to 60 MPa, temperatures up to 120°C, and at high gas partial pressure. The composition and partial pressure of gasses can be manipulated during the experiment. To keep costs low, the system is mainly made from off-the-shelf components with only very few custom-made parts. A flexible and inert PVDF (polyvinylidene fluoride) incubator sleeve, which is almost impermeable for gases, holds the sample and separates it from the pressure fluid. The flexibility of the incubator sleeve allows for sub-sampling of the medium without loss of pressure. Experiments can be run in both static and flow-through mode. The incubation system described here is usable for versatile purposes, not only the incubation of microorganisms and determination of growth rates, but also for chemical degradation or extraction experiments under high gas saturation, e.g., fluid–gas–rock-interactions in relation to carbon dioxide sequestration. As an application of the system we extracted organic compounds from sub-bituminous coal using H2O as well as a H2O–CO2 mixture at elevated temperature (90°C) and pressure (5 MPa). Subsamples were taken at different time points during the incubation and analyzed by ion chromatography. Furthermore we demonstrated the applicability of the system for studies of microbial activity, using samples from the Isis mud volcano. We could

  13. Static respiratory muscle work during immersion with positive and negative respiratory loading.

    PubMed

    Taylor, N A; Morrison, J B

    1999-10-01

    Upright immersion imposes a pressure imbalance across the thorax. This study examined the effects of air-delivery pressure on inspiratory muscle work during upright immersion. Eight subjects performed respiratory pressure-volume relaxation maneuvers while seated in air (control) and during immersion. Hydrostatic, respiratory elastic (lung and chest wall), and resultant static respiratory muscle work components were computed. During immersion, the effects of four air-delivery pressures were evaluated: mouth pressure (uncompensated); the pressure at the lung centroid (PL,c); and at PL,c +/-0.98 kPa. When breathing at pressures less than the PL,c, subjects generally defended an expiratory reserve volume (ERV) greater than the immersed relaxation volume, minus residual volume, resulting in additional inspiratory muscle work. The resultant static inspiratory muscle work, computed over a 1-liter tidal volume above the ERV, increased from 0.23 J. l(-1), when subjects were breathing at PL,c, to 0.83 J. l(-1) at PL,c -0.98 kPa (P < 0.05), and to 1.79 J. l(-1) at mouth pressure (P < 0.05). Under the control state, and during the above experimental conditions, static expiratory work was minimal. When breathing at PL,c +0.98 kPa, subjects adopted an ERV less than the immersed relaxation volume, minus residual volume, resulting in 0.36 J. l(-1) of expiratory muscle work. Thus static inspiratory muscle work varied with respiratory loading, whereas PL,c air supply minimized this work during upright immersion, restoring lung-tissue, chest-wall, and static muscle work to levels obtained in the control state.

  14. Permeability changes induced by microfissure closure and opening in tectonized materials. Effect on slope pore pressure regime.

    NASA Astrophysics Data System (ADS)

    De la Fuente, Maria; Vaunat, Jean; Pedone, Giuseppe; Cotecchia, Federica; Sollecito, Francesca; Casini, Francesca

    2015-04-01

    Tectonized clays are complex materials characterized by several levels of structures that may evolve during load and wetting/drying processes. Some microstructural patterns, as microfissures, have a particular influence on the value of permeability which is one of the main factors controlling pore pressure regime in slopes. In this work, the pore pressure regime measured in a real slope of tectonized clay in Southern Italy is analyzed by a numerical model that considers changes in permeability induced by microfissure closure and opening during the wetting and drying processes resulting from climatic actions. Permeability model accounts for the changes in Pore Size Distribution observed by Microscopy Intrusion Porosimetry. MIP tests are performed on representative samples of ground in initial conditions ("in situ" conditions) and final conditions (deformed sample after applying a wetting path that aims to reproduce the saturation of the soil under heavy rains). The resulting measurements allow for the characterization at microstructural level of the soil, identifying the distribution of dominant families pores in the sample and its evolution under external actions. Moreover, comparison of pore size density functions allows defining a microstructural parameter that depends on void ratio and degree of saturation and controls the variation of permeability. Model has been implemented in a thermo-hydro-mechanical code provided with a special boundary condition for climatic actions. Tool is used to analyze pore pressure measurements obtained in the tectonized clay slope. Results are analyzed at the light of the effect that permeability changes during wetting and drying have on the pore pressure regime.

  15. Effects of pressure and pressure cycling on disinfection of Enterococcus sp. in seawater using pressurized carbon dioxide with different content rates.

    PubMed

    Dang, Loc T T; Imai, Tsuyoshi; Le, Tuan V; Nishihara, Satoshi; Higuchi, Takaya; Nguyen, Mai K D; Kanno, Ariyo; Yamamoto, Koichi; Sekine, Masahiko

    2016-09-18

    Interest is growing in a disinfection technique for water treatment without disinfection byproducts. This study presents the result of using a liquid-film-forming apparatus at less than 1.0 MPa for disinfection of seawater. The sensitivity of Enterococcus sp. (ATCC 202155) to the pressurized carbon dioxide (CO2) was examined under various conditions of pressure cycling, pressure, working volume ratio (WVR), and CO2 content rate. The key influences on frequency and magnitude of pressure cycling in enhancing Enterococcus sp. inactivation are elucidated. The results reveal strong correlation between pressure cycling and inactivation efficiency (P-value < 0.001). The outcome of linear regression model analysis suggests that the model can explain 93%, 85%, and 89% of the inactivation efficiency of (25% CO2 + 75% N2), (50% CO2 + 50% N2), and 100% CO2, respectively. The predicted value was fit with experimental results (p-value <0.05). Under identical treatment conditions (pressure = 0.9 MPa, ΔP = 0.14 MPa, 70% WVR, and 20 ± 1°C), treatment with pressurized CO2 (100% purity) resulted in complete inactivation 5.2 log of Enterococcus sp. after 70 cycles within 20 min. The Enterococcus sp. inactivation of pressurized CO2 followed first-order reaction kinetics. The smallest D-value (largest k-value) was induced by pressurized CO2 (100% purity) at 0.9 MPa, which was obtained at 3.85 min (0.5988 min(-1), R(2) ≥ 0.95). The findings could provide an effective method for enhanced bactericidal performance of pressurized CO2, to address recently emerging problems in water disinfection.

  16. Reconstruction of pressure sores with perforator-based propeller flaps.

    PubMed

    Jakubietz, Rafael G; Jakubietz, Danni F; Zahn, Robert; Schmidt, Karsten; Meffert, Rainer H; Jakubietz, Michael G

    2011-03-01

    Perforator flaps have been successfully used for reconstruction of pressure sores. Although V-Y advancement flaps approximate debrided wound edges, perforator-based propeller flaps allow rotation of healthy tissue into the defect. Perforator-based propeller flaps were planned in 13 patients. Seven pressure sores were over the sacrum, five over the ischial tuberosity, and one on the tip of the scapula. Three patients were paraplegic, six were bedridden, and five were ambulatory. In three patients, no perforators were found. In 10 patients, propeller flaps were transferred. In two patients, total flap necrosis occurred, which was reconstructed with local advancement flaps. In two cases, a wound dehiscence occurred and had to be revised. One hematoma required evacuation. No further complications were noted. No recurrence at the flap site occurred. Local perforator flaps allow closure of pressure sores without harvesting muscle. The propeller version has the added benefit of transferring tissue from a distant site, avoiding reapproximation of original wound edges. Twisting of the pedicle may cause torsion and venous obstruction. This can be avoided by dissecting a pedicle of at least 3 cm. Propeller flaps are a safe option for soft tissue reconstruction of pressure sores. © Thieme Medical Publishers.

  17. Device for testing closure disks at high rates of change of pressure

    DOEpatents

    Merten, C.W. Jr.

    1993-11-09

    A device is described for testing the burst pressure of closure disks which provides high pressure to both sides of a disk and rapidly releases pressure from one side thereof causing a high rate of change of pressure. A hollow notched plug allows the rapid release of pressure upon rupturing. A means is also disclosed for transmitting a tensile load from a piston to a hollow notched plug and for sealing the means for transmitting load within a hole in a piston. 5 figures.

  18. External jugular venous pressure as an alternative to conventional central venous pressure in right lobe donor hepatectomies.

    PubMed

    Abdullah, Mohamed Hussein; Soliman, Hossam El Deen; Morad, Wessam Saber

    2011-12-01

    Many centers have adopted central vein cannulation both for central venous pressure monitoring and fluid administration for right hepatectomy in living-liver donors. However, use of central venous catheters is associated with adverse events that are hazardous to patients and expensive to treat. This study sought to examine the use of external jugular venous pressure as an alternative to conventional central venous pressure in right lobe donor hepatectomies Forty ASA grade I adult living liver-donors without a known history of significant cardiac or pulmonary diseases were enrolled in this prospective observational study. Paired measurement of venous pressures (external jugular venous pressure and internal jugular venous pressure) were taken at the following times: after induction of anesthesia, 30 minutes after skin incision, during right lobe mobilization (every 15 minutes), during hepatic transaction (every 15 minutes), after right lobe resection (every 15 minutes), and after abdominal closure. Paired measurements were equal in 47.5%, 53.5%, 61.5%, 46.3%, and 52.5% for after induction, after skin incision, right lobe mobilization, right lobe transection, after resection, and before abdominal closure periods. However, all measurements were within acceptable limits of bias measurements (± 2 mm Hg). Central venous pressure catheter placement can be avoided and replaced by a less-invasive method such as external jugular venous pressure (which gave an acceptable estimate of central venous pressure in all phases of right lobe resection) in living-donor liver transplant and allowed equivalent monitor even during fluid restriction phases.

  19. Spacecraft Maximum Allowable Concentrations for Selected Airborne Contaminants. Volume 2

    NASA Technical Reports Server (NTRS)

    1996-01-01

    The National Aeronautics and Space Administration (NASA) is aware of the potential toxicological hazards to humans that might be associated with prolonged spacecraft missions. Despite major engineering advances in controlling the atmosphere within spacecraft, some contamination of the air appears inevitable. NASA has measured numerous airborne contaminants during space missions. As the missions increase in duration and complexity, ensuring the health and well-being of astronauts traveling and working in this unique environment becomes increasingly difficult. As part of its efforts to promote safe conditions aboard spacecraft, NASA requested the National Research Council (NRC) to develop guidelines for establishing spacecraft maximum allowable concentrations (SMACs) for contaminants, and to review SMACs for various space-craft contaminants to determine whether NASA's recommended exposure limits are consistent with the guidelines recommended by the subcommittee. In response to NASA's request, the NRC organized the Subcommittee on Guidelines for Developing Spacecraft Maximum Allowable Concentrations for Space Station Contaminants within the Committee On Toxicology (COT). In the first phase of its work, the subcommittee developed the criteria and methods for preparing SMACs for spacecraft contaminants. The subcommittee's report, entitled Guidelines for Developing Spacecraft Maximum Allowable Concentrations for Space Station Contaminants, was published in 1992. The executive summary of that report is reprinted as Appendix A of this volume. In the second phase of the study, the Subcommittee on Spacecraft Maximum Allowable Concentrations reviewed reports prepared by NASA scientists and contractors recommending SMACs for approximately 35 spacecraft contaminants. The subcommittee sought to determine whether the SMAC reports were consistent with the 1992 guidelines. Appendix B of this volume contains the SMAC reports for 12 chemical contaminants that have been reviewed for

  20. Numerical Investigation of Pressure Profile in Hydrodynamic Lubrication Thrust Bearing.

    PubMed

    Najar, Farooq Ahmad; Harmain, G A

    2014-01-01

    Reynolds equation is solved using finite difference method (FDM) on the surface of the tilting pad to find the pressure distribution in the lubricant oil film. Different pressure profiles with grid independence are described. The present work evaluates pressure at various locations after performing a thorough grid refinement. In recent similar works, this aspect has not been addressed. However, present study shows that it can have significant effect on the pressure profile. Results of a sector shaped pad are presented and it is shown that the maximum average value of pressure is 12% (approximately) greater than the previous results. Grid independence occurs after 24 × 24 grids. A parameter "ψ" has been proposed to provide convenient indicator of obtaining grid independent results. ψ = |(P refinedgrid - P Refrence-grid)/P refinedgrid|, ψ ≤ ε, where "ε" can be fixed to a convenient value and a constant minimum film thickness value of 75 μm is used in present study. This important parameter is highlighted in the present work; the location of the peak pressure zone in terms of (r, θ) coordinates is getting shifted by changing the grid size which will help the designer and experimentalist to conveniently determine the position of pressure measurement probe.

  1. Numerical Investigation of Pressure Profile in Hydrodynamic Lubrication Thrust Bearing

    PubMed Central

    Najar, Farooq Ahmad; Harmain, G. A.

    2014-01-01

    Reynolds equation is solved using finite difference method (FDM) on the surface of the tilting pad to find the pressure distribution in the lubricant oil film. Different pressure profiles with grid independence are described. The present work evaluates pressure at various locations after performing a thorough grid refinement. In recent similar works, this aspect has not been addressed. However, present study shows that it can have significant effect on the pressure profile. Results of a sector shaped pad are presented and it is shown that the maximum average value of pressure is 12% (approximately) greater than the previous results. Grid independence occurs after 24 × 24 grids. A parameter “ψ” has been proposed to provide convenient indicator of obtaining grid independent results. ψ = |(P refinedgrid − P Refrence-grid)/P refinedgrid|, ψ ≤ ε, where “ε” can be fixed to a convenient value and a constant minimum film thickness value of 75 μm is used in present study. This important parameter is highlighted in the present work; the location of the peak pressure zone in terms of (r, θ) coordinates is getting shifted by changing the grid size which will help the designer and experimentalist to conveniently determine the position of pressure measurement probe. PMID:27350977

  2. Blood pressure monitor with a position sensor for wrist placement to eliminate hydrostatic pressure effect on blood pressure measurement.

    PubMed

    Sato, Hironori; Koshimizu, Hiroshi; Yamashita, Shingo; Ogura, Toshihiko

    2013-01-01

    Accurate measurement of blood pressure at wrist requires the heart and wrist to be kept at the same level to avoid the effects of hydrostatic pressure. Although a blood pressure monitor with a position sensor that guides appropriate forearm angle without use of a chair and desk has already been proposed, a similar functioning device for measuring upper arm blood pressure with a chair and desk is needed. In this study, a calculation model was first used to explore design of such a system. The findings were then implemented into design of a new blood pressure monitor. Results of various methods were compared. The calculation model of the wrist level from arthrosis angles and interarticulars lengths was developed and considered using published anthropometric dimensions. It is compared with 33 volunteer persons' experimental results. The calculated difference of level was -4.1 to 7.9 (cm) with a fixed chair and desk. The experimental result was -3.0 to 5.5 (cm) at left wrist and -2.1 to 6.3(cm) at right wrist. The absolute difference level equals ±4.8 (mmHg) of blood pressure readings according to the calculated result. This meets the AAMI requirements for a blood pressure monitor. In the conclusion, the calculation model is able to effectively evaluate the difference between the heart and wrist level. Improving the method for maintaining wrist to heart level will improve wrist blood pressure measurement accuracy when also sitting in the chair at a desk. The leading angle of user's forearm using a position sensor is shown to work for this purpose.

  3. Using a case-mix-adjusted pressure sore incidence study in a surgical directorate to improve patient outcomes in pressure ulcer prevention.

    PubMed

    Watret, L

    1999-10-01

    The Glasgow Acute Clinical Audit Sub-Committee on Pressure Sores has previously carried out studies of incidence of pressure ulcers in the medical directorates and case-mix-adjusted the figures for length of hospital stay and risk assessment score. Case-mix classification is 'classification of people or treatment placed into groups using characteristics associated with condition, treatment or outcome that can be used to predict need, resource, use of outcomes'. In this instance, crude pressure ulcer incidence figures may be adjusted for length of hospital stay and pressure sore risk assessment score, and stratified into groups, which allows like to be compared with like. The value in case-mix-adjusted figures lies in repeating the exercise, thus determining the trend for individual areas and assessing whether improvement in the quality of care is being achieved. This is more positive than creation of 'league tables' comparing simultaneous studies in a number of areas. The figures showed that there was no statistically significant difference between surgical directorates in trusts with regard to risk assessment scores and length of hospital stay. Gathering data on the incidence of pressure ulcer development allows us to identify where new sores are occurring, but does not critically analyse the nursing intervention taken in individual cases, which identifies preventive strategies. The Glasgow group's primary aim was to gather data on case-mix-adjusted incidence of pressure damage; the secondary objectives were to scrutinize the data to gather more general information on intrinsic and extrinsic factors which may predispose to pressure ulcer development. The study was carried out in the surgical directorate. Findings showed that incidence was low (1.1%), with the majority of sores being superficial. There was a correlation between pressure ulcer development and incontinence, evidence of under-utilization of moving and handling aids for prevention of pressure ulcers

  4. Negative-pressure and low-pressure hydrocephalus: the role of cerebrospinal fluid leaks resulting from surgical approaches to the cranial base.

    PubMed

    Filippidis, Aristotelis S; Kalani, M Yashar S; Nakaji, Peter; Rekate, Harold L

    2011-11-01

    Negative-pressure and low-pressure hydrocephalus are rare clinical entities that are frequently misdiagnosed. They are characterized by recurrent episodes of shunt failure because the intracranial pressure is lower than the opening pressure of the valve. In this report the authors discuss iatrogenic CSF leaks as a cause of low- or negative-pressure hydrocephalus after approaches to the cranial base. The authors retrospectively reviewed cases of low-pressure or negative-pressure hydrocephalus presenting after cranial approaches complicated with a CSF leak at their institution. Three patients were identified. Symptoms of high intracranial pressure and ventriculomegaly were present, although the measured pressures were low or negative. A blocked communication between the ventricles and the subarachnoid space was documented in 2 of the cases and presumed in the third. Shunt revisions failed repeatedly. In all cases, temporary clinical and radiographic improvement resulted from external ventricular drainage at subatmospheric pressures. The CSF leaks were sealed and CSF communication was reestablished operatively. In 1 case, neck wrapping was used with temporary success. Negative-pressure or low-pressure hydrocephalus associated with CSF leaks, especially after cranial base approaches, is difficult to treat. The solution often requires the utilization of subatmospheric external ventricular drains to establish a lower ventricular drainage pressure than the drainage pressure created in the subarachnoid space, where the pressure is artificially lowered by the CSF leak. Treatment involves correction of the CSF leak, neck wrapping to increase brain turgor and allow the pressure in the ventricles to rise to the level of the opening pressure of the valve, and reestablishing the CSF route.

  5. Law of Strata Pressure Behavior in Shallow Coal Seam

    NASA Astrophysics Data System (ADS)

    Zhao, Jian; Liu, Leibin; Zheng, Zhiyang

    2018-02-01

    The law of strata pressure behavior in shallow coal seam is analyzed, according to the load data of Jinjie Coal Mine 31109 working face hydraulic supports. The first weighting distance of main roof is 80 m, and the periodic weighting distance of main roof is about 20 m. And according to the load data in the middle and both ends of the working face, the working resistance of hydraulic supports and the setting load are a bit small, so they couldn’t meet the needs of supporting roof. Then, the front abutment pressure of working face is analyzed by numerical simulation. It does not only explain the reason that the load is too big, but also explains the reason that the strata pressure behavior in shallow coal seam is serious. The length of undamaged main roof rock beam verifies the correctness of the periodic weighting distance.

  6. High pressure neon arc lamp

    DOEpatents

    Sze, Robert C.; Bigio, Irving J.

    2003-07-15

    A high pressure neon arc lamp and method of using the same for photodynamic therapies is provided. The high pressure neon arc lamp includes a housing that encloses a quantity of neon gas pressurized to about 500 Torr to about 22,000 Torr. At each end of the housing the lamp is connected by electrodes and wires to a pulse generator. The pulse generator generates an initial pulse voltage to breakdown the impedance of the neon gas. Then the pulse generator delivers a current through the neon gas to create an electrical arc that emits light having wavelengths from about 620 nanometers to about 645 nanometers. A method for activating a photosensitizer is provided. Initially, a photosensitizer is administered to a patient and allowed time to be absorbed into target cells. Then the high pressure neon arc lamp is used to illuminate the target cells with red light having wavelengths from about 620 nanometers to about 645 nanometers. The red light activates the photosensitizers to start a chain reaction that may involve oxygen free radicals to destroy the target cells. In this manner, a high pressure neon arc lamp that is inexpensive and efficiently generates red light useful in photodynamic therapy is provided.

  7. Investigation of the surface free energy of the ITO thin films deposited under different working pressure

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Özen, Soner, E-mail: osoner@ogu.edu.tr; Pat, Suat; Korkmaz, Şadan

    This study discusses the influence of working pressure on the surface energy of the ITO thin films produced by radio frequency magnetron sputtering method. Optical tensiometer (Attension Theta Lite) is used for evaluating wetting behavior of the water droplet on the film surface and Equation of State method was selected to determine surface free energy for this study. Equation of state method does not divide the surface tension into different components such as polar, dispersive, acid-base. It is calculated the surfaces’ free energy measuring the contact angle with a single liquid. The surface free energy value was in the rangemore » of 15-31 mN/m. Also, the transmittances were determined in the wavelength range between 200 and 1000 nm using the UNICO 4802 UV-Vis double beam spectrophotometer. Transmittances of the produced ITO thin films are greater than %70 in the visible range.« less

  8. High pressure research using muons at the Paul Scherrer Institute

    NASA Astrophysics Data System (ADS)

    Khasanov, R.; Guguchia, Z.; Maisuradze, A.; Andreica, D.; Elender, M.; Raselli, A.; Shermadini, Z.; Goko, T.; Knecht, F.; Morenzoni, E.; Amato, A.

    2016-04-01

    Pressure, together with temperature and magnetic field, is an important thermodynamical parameter in physics. Investigating the response of a compound or of a material to pressure allows to elucidate ground states, investigate their interplay and interactions and determine microscopic parameters. Pressure tuning is used to establish phase diagrams, study phase transitions and identify critical points. Muon spin rotation/relaxation (μSR) is now a standard technique making increasing significant contribution in condensed matter physics, material science research and other fields. In this review, we will discuss specific requirements and challenges to perform μSR experiments under pressure, introduce the high pressure muon facility at the Paul Scherrer Institute (PSI, Switzerland) and present selected results obtained by combining the sensitivity of the μSR technique with pressure.

  9. SPAKling insight into blood pressure regulation

    PubMed Central

    Castañeda-Bueno, María; Gamba, Gerardo

    2010-01-01

    Arterial hypertension is one of the most important health problems in industrialized cities. Blood pressure levels are influenced by renal salt handling and salt reabsorption in the kidney. In this Closeup, Castañeda-Bueno and Gamba discuss the work from Alessi and coworkers on the in vivo roles of the SPAK kinase in defining blood pressure levels. PMID:20112249

  10. Role Resources and Work-Family Enrichment: The Role of Work Engagement

    ERIC Educational Resources Information Center

    Siu, Oi-ling; Lu, Jia-fang; Brough, Paula; Lu, Chang-qin; Bakker, Arnold B.; Kalliath, Thomas; O'Driscoll, Michael; Phillips, David R.; Chen, Wei-qing; Lo, Danny; Sit, Cindy; Shi, Kan

    2010-01-01

    This article proposes a theoretical model of work-family enrichment and tests the mediating role of work engagement. The inclusion of work engagement extends prior research on work-family interface, and allows for examination of the effects of role resources (job resources, family support) on work-family enrichment. A two-wave survey was conducted…

  11. Allowance market pricing indicators

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Miller, R.W.

    1995-12-31

    Regardless of whether buyers and sellers rely on one allowance price indicator or a combination of several, the publication of price indicators has facilitated trading in the SO{sub 2} allowance market. Buyers and sellers feel more comfortable with a price benchmark against which to measure their actions; liquidity has increased; and transactions are easier to conclude. At this market`s present stage of development, five price indicators are worthy of discussion: EPA Allowance Auctions; Compliance Strategies Review`s EATX; Utility Environment Report`s price range; Cantor Fitzgerald`s Allowance Price Indicators; and Emissions Exchange Corporation`s Exchange Values. But experience in other markets indicates thatmore » (1) others will be created as the market develops, and (2) all published price indicators will tend to converge as time passes.« less

  12. Multichannel sound reinforcement systems at work in a learning environment

    NASA Astrophysics Data System (ADS)

    Malek, John; Campbell, Colin

    2003-04-01

    Many people have experienced the entertaining benefits of a surround sound system, either in their own home or in a movie theater, but another application exists for multichannel sound that has for the most part gone unused. This is the application of multichannel sound systems to the learning environment. By incorporating a 7.1 surround processor and a touch panel interface programmable control system, the main lecture hall at the University of Michigan Taubman College of Architecture and Urban Planning has been converted from an ordinary lecture hall to a working audiovisual laboratory. The multichannel sound system is used in a wide variety of experiments, including exposure to sounds to test listeners' aural perception of the tonal characteristics of varying pitch, reverberation, speech transmission index, and sound-pressure level. The touch panel's custom interface allows a variety of user groups to control different parts of the AV system and provides preset capability that allows for numerous system configurations.

  13. Modeling Scala Media as a Pressure Vessel

    NASA Astrophysics Data System (ADS)

    Lepage, Eric; Olofsson, A.˚Ke

    2011-11-01

    The clinical condition known as endolymphatic hydrops is the swelling of scala media and may result in loss in hearing sensitivity consistent with other forms of low-frequency biasing. Because outer hair cells (OHCs) are displacement-sensitive and hearing levels tend to be preserved despite large changes in blood pressure and CSF pressure, it seems unlikely that the OHC respond passively to changes in static pressures in the chambers. This suggests the operation of a major feedback control loop which jointly regulates homeostasis and hearing sensitivity. Therefore the internal forces affecting the cochlear signal processing amplifier cannot be just motile responses. A complete account of the cochlear amplifier must include static pressures. To this end we have added a third, pressure vessel to our 1-D 140-segment, wave-digital filter active model of cochlear mechanics, incorporating the usual nonlinear forward transduction. In each segment the instantaneous pressure is the sum of acoustic pressure and global static pressure. The object of the model is to maintain stable OHC operating point despite any global rise in pressure in the third chamber. Such accumulated pressure is allowed to dissipate exponentially. In this first 3-chamber implementation we explore the possibility that acoustic pressures are rectified. The behavior of the model is critically dependent upon scaling factors and time-constants, yet by initial assumption, the pressure tends to accumulate in proportion to sound level. We further explore setting of the control parameters so that the accumulated pressure either stays within limits or may rise without bound.

  14. Double Exposure to Adverse Psychosocial Work Factors and High Family Responsibilities as Related to Ambulatory Blood Pressure at Work: A 5-Year Prospective Study in Women With White-Collar Jobs.

    PubMed

    Gilbert-Ouimet, Mahée; Brisson, Chantal; Milot, Alain; Vézina, Michel

    2017-06-01

    Accumulating evidence shows that psychosocial work factors of the demand-control and effort-reward imbalance models may contribute to increase blood pressure (BP). Women are more likely to be exposed to these psychosocial factors than men. Moreover, women spend twice as much time per week performing family responsibilities than men. This study aimed to evaluate the longitudinal association of the double exposure to psychosocial work factors and high family responsibilities in women with BP for a 5-year follow-up. At baseline, the study sample was composed of 1215 working women. Psychosocial work factors were measured using validated scales. Family responsibilities were measured using items related to "the number of children and their age" and "housework and children care." Ambulatory BP measures were taken every 15 minutes during a working day. Associations between psychosocial measures and BP were examined using analyses of covariance. Women with a double exposure to effort-reward imbalance and high family responsibilities had significantly higher BP means than women not exposed to these factors at baseline (diastolic: +2.75 mm Hg), at 3-year follow-up (systolic: +2.22 mm Hg and diastolic: +2.55 mm Hg), and at 5-year follow-up (systolic: +2.94 mm Hg and diastolic: + 3.10 mm Hg). No adverse effect on BP was observed for the double exposure to the psychosocial work factors of the demand-control model and high family responsibilities. A double exposure to effort-reward imbalance at work and high family responsibilities might contribute to elevated ambulatory BP at work among women. BP elevations related to this double exposure may persist for several years.

  15. Dorsalis pedis arterial pressure is lower than noninvasive arm blood pressure in normotensive patients under sevoflurane anesthesia.

    PubMed

    Chen, Yan; Wang, Enqin; Zhu, Yuan; Li, Yongshuai; Lu, Kaizhi

    2016-02-01

    It is widely known that blood pressure (BP) in the lower extremity is higher than in the upper extremity. However, whether this phenomenon remains the same during general anesthesia is still unclear. This study aims to investigate the difference between invasive dorsalis pedis artery (DPA) pressure and the most commonly used noninvasive arm pressure during sevoflurane anesthesia. A total of 50 normotensive Chinese patients were enrolled in this observational study. Invasive DPA pressure, noninvasive arm pressure, and systemic vascular resistance index were assessed simultaneously. BP data during the entire surgery were analyzed through a Bland-Altman plot for repeated measures. The concordance of BP variation in the DPA and the arm was analyzed using four-quadrant plots and linear regression. The time-dependent changes in BP and the systemic vascular resistance index were also evaluated. Data from 46 effective cases were analyzed. Bias (95% limits of agreement) was -7.40 mmHg (-20.36 to +5.57 mmHg) for mean blood pressure, +3.54 mmHg (-20.32 to +27.41 mmHg) for systolic blood pressure, and -10.20 mmHg (-23.66 to +3.26 mmHg) for diastolic blood pressure, respectively. The concordance of BP variation at the two measurement sites was clinically acceptable. DPA pressure and vascular resistance in the lower limb decreased gradually during surgery. DPA pressure tends to be lower than arm pressure under sevoflurane anesthesia, especially the mean blood pressure and the diastolic blood pressure. Hence, noninvasive arm BP monitoring is recommend to be retained when invasive BP is measured at the DPA, so as to allow clinicians to comprehensively evaluate the BP condition of the patients and make appropriate therapeutic decisions.

  16. Astronauts Gemar and Allen work with lower body negative pressure experiment

    NASA Image and Video Library

    1994-03-05

    STS062-01-032 (4-14 March 1994) --- Astronaut Charles D. (Sam) Gemar, mission specialist, talks to ground controllers while assisting astronaut Andrew M. Allen with a "soak" in the Lower Body Negative Pressure (LBNP) apparatus on Columbia's middeck. The pair was joined by three other veteran NASA astronauts for 14-days of scientific research aboard the Space Shuttle Columbia in earth orbit.

  17. Measure of librarian pressure using fuzzy inference system: A case study in Longyan University

    NASA Astrophysics Data System (ADS)

    Huang, Jian-Jing

    2014-10-01

    As the hierarchy of middle managers in college's librarian. They may own much work pressure from their mind. How to adapt psychological problem, control the emotion and keep a good relationship in their work place, it becomes an important issue. Especially, they work in China mainland environment. How estimate the librarians work pressure and improve the quality of service in college libraries. Those are another serious issues. In this article, the authors would like discuss how can we use fuzzy inference to test librarian work pressure.

  18. Terapascal static pressure generation with ultrahigh yield strength nanodiamond.

    PubMed

    Dubrovinskaia, Natalia; Dubrovinsky, Leonid; Solopova, Natalia A; Abakumov, Artem; Turner, Stuart; Hanfland, Michael; Bykova, Elena; Bykov, Maxim; Prescher, Clemens; Prakapenka, Vitali B; Petitgirard, Sylvain; Chuvashova, Irina; Gasharova, Biliana; Mathis, Yves-Laurent; Ershov, Petr; Snigireva, Irina; Snigirev, Anatoly

    2016-07-01

    Studies of materials' properties at high and ultrahigh pressures lead to discoveries of unique physical and chemical phenomena and a deeper understanding of matter. In high-pressure research, an achievable static pressure limit is imposed by the strength of available strong materials and design of high-pressure devices. Using a high-pressure and high-temperature technique, we synthesized optically transparent microballs of bulk nanocrystalline diamond, which were found to have an exceptional yield strength (~460 GPa at a confining pressure of ~70 GPa) due to the unique microstructure of bulk nanocrystalline diamond. We used the nanodiamond balls in a double-stage diamond anvil cell high-pressure device that allowed us to generate static pressures beyond 1 TPa, as demonstrated by synchrotron x-ray diffraction. Outstanding mechanical properties (strain-dependent elasticity, very high hardness, and unprecedented yield strength) make the nanodiamond balls a unique device for ultrahigh static pressure generation. Structurally isotropic, homogeneous, and made of a low-Z material, they are promising in the field of x-ray optical applications.

  19. Terapascal static pressure generation with ultrahigh yield strength nanodiamond

    PubMed Central

    Dubrovinskaia, Natalia; Dubrovinsky, Leonid; Solopova, Natalia A.; Abakumov, Artem; Turner, Stuart; Hanfland, Michael; Bykova, Elena; Bykov, Maxim; Prescher, Clemens; Prakapenka, Vitali B.; Petitgirard, Sylvain; Chuvashova, Irina; Gasharova, Biliana; Mathis, Yves-Laurent; Ershov, Petr; Snigireva, Irina; Snigirev, Anatoly

    2016-01-01

    Studies of materials’ properties at high and ultrahigh pressures lead to discoveries of unique physical and chemical phenomena and a deeper understanding of matter. In high-pressure research, an achievable static pressure limit is imposed by the strength of available strong materials and design of high-pressure devices. Using a high-pressure and high-temperature technique, we synthesized optically transparent microballs of bulk nanocrystalline diamond, which were found to have an exceptional yield strength (~460 GPa at a confining pressure of ~70 GPa) due to the unique microstructure of bulk nanocrystalline diamond. We used the nanodiamond balls in a double-stage diamond anvil cell high-pressure device that allowed us to generate static pressures beyond 1 TPa, as demonstrated by synchrotron x-ray diffraction. Outstanding mechanical properties (strain-dependent elasticity, very high hardness, and unprecedented yield strength) make the nanodiamond balls a unique device for ultrahigh static pressure generation. Structurally isotropic, homogeneous, and made of a low-Z material, they are promising in the field of x-ray optical applications. PMID:27453944

  20. Towards traceable transient pressure metrology

    NASA Astrophysics Data System (ADS)

    Hanson, Edward; Olson, Douglas A.; Liu, Haijun; Ahmed, Zeeshan; Douglass, Kevin O.

    2018-04-01

    We describe our progress in developing the infrastructure for traceable transient measurements of pressure. Towards that end, we have built and characterized a dual diaphragm shock tube that allows us to achieve shock amplitude reproducibility of approximately 2.3% for shocks with Mach speeds ranging from 1.26-1.5. In this proof-of-concept study we use our shock tube to characterize the dynamic response of photonic sensors embedded in polydimethylsiloxane (PDMS), a material of choice for soft tissue phantoms. Our results indicate that the PDMS-embedded photonic sensors response to shock evolves over a tens to hundreds of microseconds time scale making it a useful system for studying transient pressures in soft tissue.

  1. Experimental investigation on pressurization performance of cryogenic tank during high-temperature helium pressurization process

    NASA Astrophysics Data System (ADS)

    Lei, Wang; Yanzhong, Li; Yonghua, Jin; Yuan, Ma

    2015-03-01

    Sufficient knowledge of thermal performance and pressurization behaviors in cryogenic tanks during rocket launching period is of importance to the design and optimization of a pressurization system. In this paper, ground experiments with liquid oxygen (LO2) as the cryogenic propellant, high-temperature helium exceeding 600 K as the pressurant gas, and radial diffuser and anti-cone diffuser respectively at the tank inlet were performed. The pressurant gas requirements, axial and radial temperature distributions, and energy distributions inside the propellant tank were obtained and analyzed to evaluate the comprehensive performance of the pressurization system. It was found that the pressurization system with high-temperature helium as the pressurant gas could work well that the tank pressure was controlled within a specified range and a stable discharging liquid rate was achieved. For the radial diffuser case, the injected gas had a direct impact on the tank inner wall. The severe gas-wall heat transfer resulted in about 59% of the total input energy absorbed by the tank wall. For the pressurization case with anti-cone diffuser, the direct impact of high-temperature gas flowing toward the liquid surface resulted in a greater deal of energy transferred to the liquid propellant, and the percentage even reached up to 38%. Moreover, both of the two cases showed that the proportion of energy left in ullage to the total input energy was quite small, and the percentage was only about 22-24%. This may indicate that a more efficient diffuser should be developed to improve the pressurization effect. Generally, the present experimental results are beneficial to the design and optimization of the pressurization system with high-temperature gas supplying the pressurization effect.

  2. [Effects of noninvasive proportional assist vs pressure support ventilation on respiratory work in chronic obstructive pulmonary disease patients with hypercapnia].

    PubMed

    Zhang, J H; Luo, Q; Zhang, H J; Chen, R C

    2017-06-12

    Objective: To investigate the effect of noninvasive proportional assist ventilation (PAV) on respiratory work in chronic obstructive pulmonary disease(COPD) patients, in comparison to noninvasive pressure support ventilation(PSV). Methods: Ten severe COPD patients with hypercapnia during acute exacerbation were examined. The baseline inspiratory pressure of PSV (PS) and the assistance level of PAV(PA) were titrated by patients' tolerance. In addition to the baseline PS and PA, an additional decrease by 25% (PS-=75% PS, PA-=75% PA) or increase by 25% (PS+ =125% PS, PA+ =125% PA) of the assist level were applied to the patients. After the assessment of unassisted spontaneous breathing (SB), the patient was placed on the 6 levels of noninvasive-PSV and noninvasive-PAV in random sequence. Each level lasted at least 20 minutes. Respiratory rate (RR), tidal volume (Vt), and respiratory work(Wex, Wip and Wv) were measured. Asynchrony index (AI) was calculated. Results: During ventilation, Vt was significantly higher with each assist level than with SB. The Vt was significant increased with PS+ than with PA+ . An increase in expiratory work(Wex) and decrease in inspiratory work(Wip) were observed respectively, with the increasing assist level. The inspiratory muscles assessed by Wip were more unloaded at PS compared with PA [PS: (1.59±1.27) J/min vs PA: (4.99±3.48) J/min P <0.01]. However, the Wex was significantly higher with PS+ than with PA+ [PS+ : (1.17±0.54) J/min vs PA+ : (0.49±0.56)J/min, P <0.01]. The AI was increased with the increasing assist level of PSV [PS-: (0.46±0.57)%, PS: (1.36±1.24)% PS+ : (5.26±4.77)]. No asynchrony events were observed at PA- and PA. "Runaway" (expiratory asynchrony) was observed during PA+ [AI: (2.62±2.72)%]. Conclusions: Noninvasive-PAV can increase the Vt and decrease the Wip of the COPD patients with hypercapnia and avoid the over-assistance. The "Runaway" will occur at assist level higher than that set by tolerance

  3. Sound velocity of MgSiO 3 perovskite to Mbar pressure

    NASA Astrophysics Data System (ADS)

    Murakami, Motohiko; Sinogeikin, Stanislav V.; Hellwig, Holger; Bass, Jay D.; Li, Jie

    2007-04-01

    Brillouin scattering measurements of the aggregate shear wave velocities in MgSiO 3 perovskite were conducted at high pressure conditions relevant to the Earth's lowermost mantle, approaching 1 Mbar. Infrared laser annealing of samples in a diamond anvil cell allowed us to obtain high quality Brillouin spectra and to drastically extend the upper limit of pressure for Brillouin measurements. We found that the pressure derivative of the shear modulus (d G / d P = G') of MgSiO 3 perovskite is 1.56 ± 0.04, which is distinctly lower than that of previous lower-pressure experiments below 9 GPa. Extrapolation of the high-pressure shear velocities of perovskite to ambient pressure, are in excellent agreement with earlier room pressure Brillouin measurements. The shear modulus, shear velocity and longitudinal velocity at ambient pressure were determined to be G0 = 172.9(15) GPa, VS = 6.49(3) and VP = 10.85(3) km/sec. The mineralogical model that provides a best fit to global seismological 1-D velocity profiles is one that contains 85-90 vol% perovskite in the lower mantle. The results of this study are the first to demonstrate that the elastic wave velocities for a near-adiabatic lower mantle with a bulk composition dominated by magnesium silicate perovskite are consistent with the average lower mantle seismic velocity structure. The large pressure range over which acoustic measurements of MgSiO 3 perovskite performed in this study has thus allowed us to put tighter constraints on compositional models of the Earth's lower mantle.

  4. Smart blood pressure holter.

    PubMed

    İlhan, İlhan

    2018-03-01

    In this study, a wireless blood pressure holter that can be used with smart mobile devices was developed. The developed blood pressure holter consists of two parts, which are a smart mobile device and a cuff. The smart mobile device is used as a recording, control and display device through a developed interface, while the cuff was designed to take measurements from the arm. Resistor-Capacitor (RC) and digital filters were used on the cuff that communicates with the smart mobile device via Bluetooth. The blood pressure was estimated using the Simple Hill Climbing Algorithm (HCA). It is possible to measure instantaneous or programmable blood pressure and heart rate values at certain intervals using this holter. The test was conducted with 30 individuals at different ages with the guidance of a specialist health personnel. The results showed that an accuracy at 93.89% and 91.95% rates could be obtained for systolic and diastolic pressure values, respectively, when compared with those obtained using a traditional sphygmomanometer. The accuracy level for the heart rate was measured as 97.66%. Furthermore, this device was tested day and night in the holter mode in terms of working time, the continuity of the Bluetooth connection and the reliability of the measurement results. The test results were evaluated separately in terms of measurement accuracy, working time, the continuity of the Bluetooth connection and the reliability of the measurement results. The measurement accuracy for systolic, diastolic blood pressure and heart rate values was obtained as 93.89%, 91.95% and 97.66%, respectively. The maximum number of measurements which can be conducted with four 1000 mA alkaline batteries at 20 min intervals was found approximately 79 (little more than 24 h). In addition, it was determined that the continuity of the Bluetooth connection and the reliability of the measurement results were automatically achieved through the features in the interface developed for the

  5. One-dimensional pressure transfer models for acoustic-electric transmission channels

    NASA Astrophysics Data System (ADS)

    Wilt, K. R.; Lawry, T. J.; Scarton, H. A.; Saulnier, G. J.

    2015-09-01

    A method for modeling piezoelectric-based ultrasonic acoustic-electric power and data transmission channels is presented. These channels employ piezoelectric disk transducers to convey signals across a series of physical layers using ultrasonic waves. This model decomposes the mechanical pathway of the signal into individual ultrasonic propagation layers which are generally independent of the layer's adjacent domains. Each layer is represented by a two-by-two traveling pressure wave transfer matrix which relates the forward and reverse pressure waves on one side of the layer to the pressure waves on the opposite face, where each face is assumed to be in contact with a domain of arbitrary reference acoustic impedance. A rigorous implementation of ultrasonic beam spreading is introduced and implemented within applicable domains. Compatible pressure-wave models for piezoelectric transducers are given, which relate the electric voltage and current interface of the transducer to the pressure waves on one mechanical interface while also allowing for passive acoustic loading of the secondary mechanical interface. It is also shown that the piezoelectric model's electrical interface is compatible with transmission line parameters (ABCD-parameters), allowing for connection of electronic components and networks. The model is shown to be capable of reproducing the behavior of realistic physical channels.

  6. High Pressure Composite Overwrapped Pressure Vessel (COPV) Development Tests at Cryogenic Temperatures

    NASA Technical Reports Server (NTRS)

    Ray, David M.; Greene, Nathanael J.; Revilock, Duane; Sneddon, Kirk; Anselmo, Estelle

    2008-01-01

    Development tests were conducted to evaluate the performance of 2 COPV designs at cryogenic temperatures. This allows for risk reductions for critical components for a Gaseous Helium (GHe) Pressurization Subsystem for an Advanced Propulsion System (APS) which is being proposed for NASA s Constellation project and future exploration missions. It is considered an advanced system since it uses Liquid Methane (LCH4) as the fuel and Liquid Oxygen (LO2) as the oxidizer for the propellant combination mixture. To avoid heating of the propellants to prevent boil-off, the GHe will be stored at subcooled temperatures equivalent to the LO2 temperature. Another advantage of storing GHe at cryogenic temperatures is that more mass of the pressurized GHe can be charged in to a vessel with a smaller volume, hence a smaller COPV, and this creates a significant weight savings versus gases at ambient temperatures. The major challenge of this test plan is to verify that a COPV can safely be used for spacecraft applications to store GHe at a Maximum Operating Pressure (MOP) of 4,500 psig at 140R to 160R (-320 F to -300 F). The COPVs for these tests were provided by ARDE , Inc. who developed a resin system to use at cryogenic conditions and has the capabilities to perform high pressure testing with LN2.

  7. 33 CFR 156.170 - Equipment tests and inspections.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... distort under static liquid pressure at least 11/2 times the maximum allowable working pressure; and (iv... static liquid pressure test is successfully completed in the presence of the COTP. The test medium is not... static liquid pressure at least 11/2 times the maximum allowable working pressure; and (5) Each item of...

  8. 33 CFR 156.170 - Equipment tests and inspections.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... distort under static liquid pressure at least 11/2 times the maximum allowable working pressure; and (iv... static liquid pressure test is successfully completed in the presence of the COTP. The test medium is not... static liquid pressure at least 11/2 times the maximum allowable working pressure; and (5) Each item of...

  9. 33 CFR 156.170 - Equipment tests and inspections.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... distort under static liquid pressure at least 11/2 times the maximum allowable working pressure; and (iv... static liquid pressure test is successfully completed in the presence of the COTP. The test medium is not... static liquid pressure at least 11/2 times the maximum allowable working pressure; and (5) Each item of...

  10. Design and develop speed/pressure regulator

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hasanul Basher, A.M.

    1993-09-01

    The Physics Division at Oak Ridge National Laboratory has several recirculating water cooling systems. One of them supplies deionized water at 150 psi, which is mainly used for cooling magnet windings at the Oak Ridge Isochronous Cyclotron (ORIC). The system has three 125-hp water pumps, each of which is capable of supplying water at the rate of 1000 gpm. One of the major requirements of this water supply system is that the supply pressure must be kept constant. An adjustable-frequency speed controller was recently installed to control the speed of one of the pump motors. A servo-system was provided withmore » the adjustable-frequency controller for regulating motor speed and, subsequently, the water pressure. After unsuccessful attempts to operate the servo, it was concluded that the regulator may not work for the existing system. Prior to installation of the variable-frequency controller, pressure regulation was accomplished with a pneumatically controlled load by-pass valve. To maintain constant pressure in the system, it is necessary to run always at full load, even if full load is not on the system. Hence, there is a waste of energy when full load is not connected to the system. So, designing and implementing one regulator that works at any load condition has become necessary. This report discusses the design of such a pressure regulator.« less

  11. Supporting clinician educators to achieve "work-work balance".

    PubMed

    Maniate, Jerry; Dath, Deepak; Cooke, Lara; Leslie, Karen; Snell, Linda; Busari, Jamiu

    2016-10-01

    Clinician Educators (CE) have numerous responsibilities in different professional domains, including clinical, education, research, and administration. Many CEs face tensions trying to manage these often competing professional responsibilities and achieve "work-work balance." Rich discussions of techniques for work-work balance amongst CEs at a medical education conference inspired the authors to gather, analyze, and summarize these techniques to share with others. In this paper we present the CE's "Four Ps"; these are practice points that support both the aspiring and established CE to help improve their performance and productivity as CEs, and allow them to approach work-work balance.

  12. Nurses' knowledge of pressure ulcer prevention, staging, and description.

    PubMed

    Pieper, B; Mott, M

    1995-01-01

    The purpose of this study was to examine registered nurses' (N = 228) knowledge of pressure ulcer prevention, pressure ulcer staging, and wound description. A 47-item, true-false Pressure Ulcer Knowledge Test was developed for he study. Nurses' knowledge was significantly higher the more recently they had heard a lecture or read an article about pressure ulcers. Knowledge scores were not related to educational background, age, or years of work experience.

  13. The allowance exchange - ALEX

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mangis, J.K.; Miller, C.; Nicholas, J.

    1997-12-31

    The success of market approaches to pollution control in reducing the cost of compliance with environmental regulation, has insured the inclusion of emissions trading programs in current and future regulatory programs. As these environmental trading programs multiply, (SO{sub 2}, NO{sub x}, Ozone Precursors, Wetlands, CO{sub 2} and others), utility companies will need a central location to buy, sell, and trade these allowances to meet regulatory needs. In response, SAIC has designed and prototyped an electronic trading system that can provide a common forum for the location and exchange of environmental allowances, marketable permits, and other market based instruments for environmentalmore » management. SAIC intends to open and operate the Allowance Exchange (ALEX) for the trading of all environmental allowances, associated with the operation of electric utilities, as a service to the nation, the industry, and the environmental community.« less

  14. Successful factors to prevent pressure ulcers - an interview study.

    PubMed

    Hommel, Ami; Gunningberg, Lena; Idvall, Ewa; Bååth, Carina

    2017-01-01

    To explore successful factors to prevent pressure ulcers in hospital settings. Pressure ulcer prevalence has been recognised as a quality indicator for both patient safety and quality of care in hospital and community settings. Most pressure ulcer can be prevented if effective measures are implemented and evaluated. The Swedish Association of Local Authorities and Regions initiated nationwide pressure ulcer prevalence studies in 2011. In 2014, after four years of measurement, the prevalence was still unacceptably high on a national level. The mean prevalence of pressure ulcer in the spring of 2014 was 14% in hospital settings with a range from 2·7-36·4%. Qualitative semistructured interviews were conducted. A qualitative content analysis, in addition to Promoting Action on Research Implementation in Health Services frameworks, was used in the analysis of the data text. Individual interviews and focus groups were used to create opportunities for both individual responses and group interactions. The study was conducted at six hospitals during the fall of 2014. Three main categories were identified as successful factors to prevent pressure ulcer in hospitals: creating a good organisation, maintaining persistent awareness and realising the benefits for patients. The goal for all healthcare personnel must be delivering high-quality, sustainable care to patients. Prevention of pressure ulcer is crucial in this work. It seems to be easier for small hospitals (with a low number of units/beds) to develop and sustain an effective organisation in prevention work. The nurse managers' attitude and engagement are crucial to enable the personnel to work actively with pressure ulcer prevention. Strategies are proposed to advance clinical leadership, knowledge, skills and abilities for the crucial implementation of pressure ulcer prevention. © 2016 John Wiley & Sons Ltd.

  15. High-Pressure Design of Advanced BN-Based Materials.

    PubMed

    Kurakevych, Oleksandr O; Solozhenko, Vladimir L

    2016-10-20

    The aim of the present review is to highlight the state of the art in high-pressure design of new advanced materials based on boron nitride. Recent experimental achievements on the governing phase transformation, nanostructuring and chemical synthesis in the systems containing boron nitride at high pressures and high temperatures are presented. All these developments allowed discovering new materials, e.g., ultrahard nanocrystalline cubic boron nitride (nano-cBN) with hardness comparable to diamond, and superhard boron subnitride B 13 N₂. Thermodynamic and kinetic aspects of high-pressure synthesis are described based on the data obtained by in situ and ex situ methods. Mechanical and thermal properties (hardness, thermoelastic equations of state, etc.) are discussed. New synthetic perspectives, combining both soft chemistry and extreme pressure-temperature conditions are considered.

  16. Simplifying the design of microstructured optical fibre pressure sensors.

    PubMed

    Osório, Jonas H; Chesini, Giancarlo; Serrão, Valdir A; Franco, Marcos A R; Cordeiro, Cristiano M B

    2017-06-07

    In this paper, we propose a way to simplify the design of microstructured optical fibres with high sensitivity to applied pressure. The use of a capillary fibre with an embedded core allows the exploration of the pressure-induced material birefringence due to the capillary wall displacements and the photoelastic effect. An analytical description of pressure-induced material birefringence is provided, and fibre modal characteristics are explored through numerical simulations. Moreover, a capillary fibre with an embedded core is fabricated and used to probe pressure variations. Even though the embedded-core fibre has a non-optimized structure, measurements showed a pressure sensitivity of (1.04 ± 0.01) nm/bar, which compares well with more complex, specially designed fibre geometries reported in the literature. These results demonstrate that this geometry enables a novel route towards the simplification of microstructured fibre-based pressure sensors.

  17. Overseas Cost of Living Allowances (COLA)

    Science.gov Websites

    ) Government Meal Rate Meal Tickets Mileage Rates Overseas Cost of Living Allowances (COLA) Calculation of Reporting Procedures Station Allowance Changes Programs & Services > Allowances > Overseas Cost of Allowances Submit Questions Overseas Cost of Living Allowances (COLA) The Overseas Cost of Living Allowance

  18. [Having trouble with pressure ulcers care?].

    PubMed

    Mizuno, Masako; Noda, Yasuhiro; Nohara, Yoko; Fujii, Keiko; Sato, Noriko; Renda, Akiyoshi; Yuasa, Takashi; Muramatsu, Shuichi; Furuta, Katsunori

    2004-12-01

    Since 1997, we, the community pharmacists, have established this society, Aichi Prefecture Society for the Study of Pressure Ulcers Care, in order to furnish drug information about pressure ulcers care. Moist atmosphere is required for the healing of pressure ulcers. The moist environment that could be regulated depends on the physicochemical property of ointment bases. Therefore, ointment should reasonably be chosen to adjust the moisture. Since 2000, we have been committed to providing pharmacists, who work on home care, with a booklet to instruct how to choose ointments for pressure ulcers treatment. In 2002, when the Aichi pharmaceutical association held a training conference held at various hospitals using the booklet as a teaching material, hospital pharmacists cooperated by making a field study trip to observe pressure ulcers treatments. Nowadays researchers at pharmaceutical colleges have also cooperated in studying the efficacy and economical effect of the method of blending different ointments to improve the healing process of pressure ulcers.

  19. Hydrogeological conceptual model determined from baseline and construction phase groundwater pressure and surface tilt-meter data at the Mizunami underground research laboratory, Japan

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Takeuchi, Shinji; Takeuchi, Ryuji; Salden, Walter

    2007-07-01

    A hydrogeological conceptual model has been developed based on pressure responses observed at multilevel pressure monitoring zones in seven boreholes and surface tilt data in and around the Mizunami Underground Research Laboratory site. Pressure changes caused by some earthquakes, cross-hole hydraulic testing, and shaft excavation activities are considered. Surface tilt has been measured from the half way of the shaft excavation phase. The shaft excavation has been commenced from July 2003 with two shafts (Main shaft and Ventilation shaft). By the end of October 2005, discharging of water in the shafts has been halted at the depths of 172 mmore » and 191 m respectively to allow modifications to be made to the water treatment facility due to an excess of F and B concentration in the water. This results in the recovery of the groundwater levels and filling of the underground workings. Beginning in February 2006 pumping has been resumed and the underground workings have been re-occupied. Continuous groundwater pressure and surface tilt measurements with some numerical analysis during the shaft excavation phase show the existence of the flow barrier fault predicted from the surface-based investigation phase and hydraulic parameter around the shafts. (authors)« less

  20. HDU Pressurized Excursion Module (PEM) Prototype Systems Integration

    NASA Technical Reports Server (NTRS)

    Gill, Tracy R.; Kennedy, Kriss; Tri, Terry; Toups, Larry; Howe, A. Scott

    2010-01-01

    The Habitat Demonstration Unit (HDU) project team constructed an analog prototype lunar surface laboratory called the Pressurized Excursion Module (PEM). The prototype unit subsystems were integrated in a short amount of time, utilizing a skunk-works approach that brought together over 20 habitation-related technologies from a variety of NASA centers. This paper describes the system integration strategies and lessons learned, that allowed the PEM to be brought from paper design to working field prototype using a multi-center team. The system integration process included establishment of design standards, negotiation of interfaces between subsystems, and scheduling fit checks and installation activities. A major tool used in integration was a coordinated effort to accurately model all the subsystems using CAD, so that conflicts were identified before physical components came together. Some of the major conclusions showed that up-front modularity that emerged as an artifact of construction, such as the eight 45 degree "pie slices" making up the module whose steel rib edges defined structural mounting and loading points, dictated much of the configurational interfaces between the major subsystems and workstations. Therefore, 'one of the lessons learned included the need to use modularity as a tool for organization in advance, and to work harder to prevent non-critical aspects of the platform from dictating the modularity that may eventually inform the fight system.

  1. Development of a Pressure Sensitive Paint System with Correction for Temperature Variation

    NASA Technical Reports Server (NTRS)

    Simmons, Kantis A.

    1995-01-01

    Pressure Sensitive Paint (PSP) is known to provide a global image of pressure over a model surface. However, improvements in its accuracy and reliability are needed. Several factors contribute to the inaccuracy of PSP. One major factor is that luminescence is temperature dependent. To correct the luminescence of the pressure sensing component for changes in temperature, a temperature sensitive luminophore incorporated in the paint allows the user to measure both pressure and temperature simultaneously on the surface of a model. Magnesium Octaethylporphine (MgOEP) was used as a temperature sensing luminophore, with the pressure sensing luminophore, Platinum Octaethylporphine (PtOEP), to correct for temperature variations in model surface pressure measurements.

  2. A platform-based foot pressure/shear sensor

    NASA Astrophysics Data System (ADS)

    Chang, Chun-Te; Liu, Chao Shih; Soetanto, William; Wang, Wei-Chih

    2012-04-01

    The proposed research is aimed at developing, fabricating and implementing a flexible fiber optic bend loss sensor for the measurement of plantar pressure and shear stress for diabetic patients. The successful development of the sensor will greatly impact the study of diabetic foot ulcers by allowing clinicians to measure a parameter (namely, shear stress) that has been implicated in ulceration, but heretofore, has not been routinely quantified on high risk patients. A full-scale foot pressure/shear sensor involves a tactile sensor array using intersecting optical waveguides is presented. The basic configuration of the optical sensor systems incorporates a mesh that is comprised of two sets of parallel optical waveguide planes; the planes are configured so the parallel rows of waveguides of the top and bottom planes are perpendicular to each other. The planes are sandwiched together creating one sensing sheet. Two-dimensional information is determined by measuring the loss of light from each of the waveguide to map the overall pressure distribution. The shifting of the layers relative to each other allows determination of the shear stress in the plane of the sensor. This paper presents latest development and improvement in the sensors design. Fabrication and results from the latest tests will be described.

  3. Disinfection of woollen blankets in steam at subatmospheric pressure

    PubMed Central

    Alder, V. G.; Gillespie, W. A.

    1961-01-01

    Blankets may be disinfected in steam at subatmospheric pressures by temperatures below boiling point inside a suitably adapted autoclave chamber. The chamber and its contents are thoroughly evacuated of air so as to allow rapid heat penetration, and steam is admitted to a pressure of 10 in. Hg below atmospheric pressure, which corresponds to a temperature of 89°C. Woollen blankets treated 50 times by this process were undamaged. Vegetative organisms were destroyed but not spores. The method is suitable for large-scale disinfection of blankets and for disinfecting various other articles which would be damaged at higher temperatures. PMID:13860203

  4. Pressurized Structure Technology for UAVS

    DTIC Science & Technology

    2008-12-01

    deficiencies of the UAVs just listed is to employ lighter-than-air or pressurized structure-based ( PSB ) technology. Basically, the UAV will be built such...that a considerable percentage of its weight is supported by or constructed from inflatable structures containing air or helium. PSB technology...neutral buoyancy will allow much slower flight speeds and increased maneuverability while expending little power. PSB airframes used in conjunction

  5. Variable pressure power cycle and control system

    DOEpatents

    Goldsberry, Fred L.

    1984-11-27

    A variable pressure power cycle and control system that is adjustable to a variable heat source is disclosed. The power cycle adjusts itself to the heat source so that a minimal temperature difference is maintained between the heat source fluid and the power cycle working fluid, thereby substantially matching the thermodynamic envelope of the power cycle to the thermodynamic envelope of the heat source. Adjustments are made by sensing the inlet temperature of the heat source fluid and then setting a superheated vapor temperature and pressure to achieve a minimum temperature difference between the heat source fluid and the working fluid.

  6. Working Out Works for Shawn Kelly | Poster

    Cancer.gov

    By Nancy Parrish, Staff Writer When Shawn Kelly found out last year that he had high blood pressure, he was determined to do something about it. Luckily for Kelly, an instrumentation technician III, Facilities Maintenance and Engineering, he works at the Advanced Technology Research Facility (ATRF), where he can take advantage of the gym there, known as the Wellness Center.

  7. [Influence of intermittently monitoring on endotracheal tube cuff pressure using handheld pressure gauge].

    PubMed

    Huang, Ling; Xie, Chen; Zhang, Lifeng; Meng, Liying; Li, Guizheng; Li, Yang; Huang, Bing; Pan, Linghui; Tang, Zhanhong

    2017-01-01

    To discuss the influence of intermittently monitoring on endotracheal tube cuff pressure using handheld pressure gauge, and to provide some reference for the clinical work. The experiment was carried out on the model of the glass tube, which was divided into three parts. Each part of the experiment was divided into normal pressure group and high pressure group according to the different inflation pressure target value. The endotracheal tube cuff pressure was determined intermittently by using the transparent tracheal models which had a static diameter of 2 cm. The target press value of normal pressure group was 32 cmH 2 O (1 cmH 2 O = 0.098 kPa) while that of high pressure group was 40 cmH 2 O. The handheld pressure gauge was connected with the indicated cuff through a tee joint, and the pressure in the cuff in both groups was determined. The pressure loss caused by intermittent measurement of the two groups was compared. By switching the tee joint, the pressure loss through the gauge self-structure and the pressure loss when connecting and disconnecting the indicated cuff were determined to analyze the causes of pressure loss caused by intermittent measurement of pressure gauge. The pressure loss caused by intermittent measurement of high pressure group was significantly higher than that of normal pressure group (cmH 2 O: 15.10±0.43 vs. 10.19±0.45) with statistical significance (t = -24.875, P = 0.000). The pressure loss through the gauge self-structure of high pressure group was also significantly higher than that of normal pressure group (cmH 2 O: 13.91±0.48 vs. 8.77±0.53), which showed a statistics significance (t = -22.854, P = 0.000). The pressure loss when connecting and disconnecting the indicated cuff of the normal pressure and high pressure groups were (1.33±0.49) cmH 2 O and (1.23±0.55) cmH 2 O, respectively, without statistics significance (t = 0.445, P = 0.662). It was figured that the total pressure loss caused by intermittent measurement of the

  8. Design principles for high–pressure force fields: Aqueous TMAO solutions from ambient to kilobar pressures

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hölzl, Christoph; Horinek, Dominik, E-mail: dominik.horinek@ur.de; Kibies, Patrick

    Accurate force fields are one of the major pillars on which successful molecular dynamics simulations of complex biomolecular processes rest. They have been optimized for ambient conditions, whereas high-pressure simulations become increasingly important in pressure perturbation studies, using pressure as an independent thermodynamic variable. Here, we explore the design of non-polarizable force fields tailored to work well in the realm of kilobar pressures – while avoiding complete reparameterization. Our key is to first compute the pressure-induced electronic and structural response of a solute by combining an integral equation approach to include pressure effects on solvent structure with a quantum-chemical treatmentmore » of the solute within the embedded cluster reference interaction site model (EC-RISM) framework. Next, the solute’s response to compression is taken into account by introducing pressure-dependence into selected parameters of a well-established force field. In our proof-of-principle study, the full machinery is applied to N,N,N-trimethylamine-N-oxide (TMAO) in water being a potent osmolyte that counteracts pressure denaturation. EC-RISM theory is shown to describe well the charge redistribution upon compression of TMAO(aq) to 10 kbar, which is then embodied in force field molecular dynamics by pressure-dependent partial charges. The performance of the high pressure force field is assessed by comparing to experimental and ab initio molecular dynamics data. Beyond its broad usefulness for designing non-polarizable force fields for extreme thermodynamic conditions, a good description of the pressure-response of solutions is highly recommended when constructing and validating polarizable force fields.« less

  9. Design principles for high-pressure force fields: Aqueous TMAO solutions from ambient to kilobar pressures.

    PubMed

    Hölzl, Christoph; Kibies, Patrick; Imoto, Sho; Frach, Roland; Suladze, Saba; Winter, Roland; Marx, Dominik; Horinek, Dominik; Kast, Stefan M

    2016-04-14

    Accurate force fields are one of the major pillars on which successful molecular dynamics simulations of complex biomolecular processes rest. They have been optimized for ambient conditions, whereas high-pressure simulations become increasingly important in pressure perturbation studies, using pressure as an independent thermodynamic variable. Here, we explore the design of non-polarizable force fields tailored to work well in the realm of kilobar pressures--while avoiding complete reparameterization. Our key is to first compute the pressure-induced electronic and structural response of a solute by combining an integral equation approach to include pressure effects on solvent structure with a quantum-chemical treatment of the solute within the embedded cluster reference interaction site model (EC-RISM) framework. Next, the solute's response to compression is taken into account by introducing pressure-dependence into selected parameters of a well-established force field. In our proof-of-principle study, the full machinery is applied to N,N,N-trimethylamine-N-oxide (TMAO) in water being a potent osmolyte that counteracts pressure denaturation. EC-RISM theory is shown to describe well the charge redistribution upon compression of TMAO(aq) to 10 kbar, which is then embodied in force field molecular dynamics by pressure-dependent partial charges. The performance of the high pressure force field is assessed by comparing to experimental and ab initio molecular dynamics data. Beyond its broad usefulness for designing non-polarizable force fields for extreme thermodynamic conditions, a good description of the pressure-response of solutions is highly recommended when constructing and validating polarizable force fields.

  10. Osmosis-Based Pressure Generation: Dynamics and Application

    PubMed Central

    Li, Suyi; Billeh, Yazan N.; Wang, K. W.; Mayer, Michael

    2014-01-01

    This paper describes osmotically-driven pressure generation in a membrane-bound compartment while taking into account volume expansion, solute dilution, surface area to volume ratio, membrane hydraulic permeability, and changes in osmotic gradient, bulk modulus, and degree of membrane fouling. The emphasis lies on the dynamics of pressure generation; these dynamics have not previously been described in detail. Experimental results are compared to and supported by numerical simulations, which we make accessible as an open source tool. This approach reveals unintuitive results about the quantitative dependence of the speed of pressure generation on the relevant and interdependent parameters that will be encountered in most osmotically-driven pressure generators. For instance, restricting the volume expansion of a compartment allows it to generate its first 5 kPa of pressure seven times faster than without a restraint. In addition, this dynamics study shows that plants are near-ideal osmotic pressure generators, as they are composed of many small compartments with large surface area to volume ratios and strong cell wall reinforcements. Finally, we demonstrate two applications of an osmosis-based pressure generator: actuation of a soft robot and continuous volume delivery over long periods of time. Both applications do not need an external power source but rather take advantage of the energy released upon watering the pressure generators. PMID:24614529

  11. Low-Speed Pressure Sensitive Paint Studies

    NASA Technical Reports Server (NTRS)

    Owen, Brown; Mehta, Rabindra; Nixon, David (Technical Monitor)

    1998-01-01

    A series of low speed (M less than 0.2) experiments using University of Washington Fib-07 Pressure Sensitive Paint (PSP) have been conducted at NASA Ames on a NACA 0012 airfoil. Significant improvements in results have been shown: PSP calibration errors of the improved data (with pressure taps as a reference) now agree with theoretical error limits. Additional measurements on the 0012 airfoil using Temperature Sensitive Paint have been made. These TSP measurements now fully quantify the impact of temporal temperature changes on model surfaces on PSP measurements. Finally, simultaneous PSP - TSP measurements have been performed, allowing in-situ temperature correction of PSP data with good results.

  12. Introduction to High-Pressure Science

    NASA Astrophysics Data System (ADS)

    Dera, Przemyslaw

    To a common person pressure is just one of the parameters that describe a thermodynamic state. We all hear about it in everyday weather forecasts, and most of us do not associate it with anything particularly unique. Probably the most intuitive idea of the effect of high-pressure comes from movies, where submarine sinking to the bottom of the ocean is gradually crushed by the surrounding water, until its hull implodes. Why, then hundreds of scientists throughout the world spent their lifelong careers studying high-pressure phenomena? Despite all the developments in experimental technologies and instrumentation, modern scientist has very few tools that allow him or her to "grab" two atoms and bring them, in a very controllable way, closer together. Being able to achieve this task means the ability to directly probe interatomic interaction potentials and can cause transformations as dramatic as turning of a common gas into solid metal. Before the reader delves into more advanced topics described later in this book, this introductory chapter aims to explain several elementary, but extremely important concepts in high-pressure science. We will start with a brief discussion of laboratory devices used to produce pressure, address the issue of hydrostaticity, elastic and plastic compression, and will conclude with a short discussion of unique effects of anisotropic stress.

  13. The Tangle of Student Allowances.

    ERIC Educational Resources Information Center

    Thomson, Norman J.

    1980-01-01

    A discussion of the distribution of student financial aid in Australia focuses on these issues: direct vs. indirect payment to students; inequality in living allowances given to secondary and postsecondary students; and distribution of expense allowances by state government and living allowances by the Commonwealth. (MSE)

  14. Air Bag Applies Uniform Bonding Pressure

    NASA Technical Reports Server (NTRS)

    Gillespie, C. A.

    1982-01-01

    Air-bag box applies constant uniform pressure to tiles and other objects undergoing adhesive bonding. Box is basically a compliant clamp with adjustable force and position. Can be used on irregular surfaces as well as on flat ones. Pressurized air is fed to bag through a tube so that it expands, filling the box and pressing against work. Bag adopts a contour that accommodates surface under open side of box.

  15. Development of a Pressure Switched Microfluidic Cell Sorter

    NASA Astrophysics Data System (ADS)

    Ozbay, Baris; Jones, Alex; Gibson, Emily

    2009-10-01

    Lab on a chip technology allows for the replacement of traditional cell sorters with microfluidic devices which can be produced less expensively and are more compact. Additionally, the compact nature of microfluidic cell sorters may lead to the realization of their application in point-of-care medical devices. Though techniques have been demonstrated previously for sorting in microfluidic devices with optical or electro-osmotic switching, both of these techniques are expensive and more difficult to implement than pressure switching. This microfluidic cell sorter design also allows for easy integration with optical spectroscopy for identification of cell type. Our current microfluidic device was fabricated with polydimethylsiloxane (PDMS), a polymer that houses the channels, which is then chemically bonded to a glass slide. The flow of fluid through the device is controlled by pressure controllers, and the switching of the cells is accomplished with the use of a high performance pressure controller interfaced with a computer. The cells are fed through the channels with the use of hydrodynamic focusing techniques. Once the experimental setup is fully functional the objective will be to determine switching rates, explore techniques to optimize these rates, and experiment with sorting of other biomolecules including DNA.

  16. The Effect of Background Pressure on Electron Acceleration from Ultra-Intense Laser-Matter Interactions

    NASA Astrophysics Data System (ADS)

    Le, Manh; Ngirmang, Gregory; Orban, Chris; Morrison, John; Chowdhury, Enam; Roquemore, William

    2017-10-01

    We present two-dimensional particle-in-cell (PIC) simulations that investigate the role of background pressure on the acceleration of electrons from ultra intense laser interaction at normal incidence with liquid density ethylene glycol targets. The interaction was simulated at ten different pressures varying from 7.8 mTorr to 26 Torr. We calculated conversion efficiencies from the simulation results and plotted the efficiencies with respect to the background pressure. The results revealed that the laser to > 100 keV electron conversion efficiency remained flat around 0.35% from 7.8 mTorr to 1.2 Torr and increased exponentially from 1.2 Torr onward to about 1.47% at 26 Torr. Increasing the background pressure clearly has a dramatic effect on the acceleration of electrons from the target. We explain how electrostatic effects, in particular the neutralization of the target by the background plasma, allows electrons to escape more easily and that this effect is strengthened with higher densities. This work could facilitate the design of future experiments in increasing laser to electron conversion efficiency and generating substantial bursts of electrons with relativistic energies. This research is supported by the Air Force Office of Scientific Research under LRIR Project 17RQCOR504 under the management of Dr. Riq Parra and Dr. Jean-Luc Cambier. Support was also provided by the DOD HPCMP Internship Program.

  17. Diagnosing and alleviating the impact of performance pressure on mathematical problem solving.

    PubMed

    DeCaro, Marci S; Rotar, Kristin E; Kendra, Matthew S; Beilock, Sian L

    2010-08-01

    High-pressure academic testing situations can lead people to perform below their actual ability levels by co-opting working memory (WM) resources needed for the task at hand (Beilock, 2008). In the current work we examine how performance pressure impacts WM and design an intervention to alleviate pressure's negative impact. Specifically, we explore the hypothesis that high-pressure situations trigger distracting thoughts and worries that rely heavily on verbal WM. Individuals performed verbally based and spatially based mathematics problems in a low-pressure or high-pressure testing situation. Results demonstrated that performance on problems that rely heavily on verbal WM resources was less accurate under high-pressure than under low-pressure tests. Performance on spatially based problems that do not rely heavily on verbal WM was not affected by pressure. Moreover, the more people reported worrying during test performance, the worse they performed on the verbally based (but not spatially based) maths problems. Asking some individuals to focus on the problem steps by talking aloud helped to keep pressure-induced worries at bay and eliminated pressure's negative impact on performance.

  18. Modeling systolic pressure variation due to positive pressure ventilation.

    PubMed

    Messerges, Joanne

    2006-01-01

    Although many clinical techniques have been proposed to assess blood volume none have been established as an undisputed standard practice, Volume studies suggest systolic pressure variation (SPV) as a promising volume indicator but underlying influences on SPV are not well understood. Successful modeling of SPV will reveal the major SPV influencers, guide algorithm development to accommodate these influencers, and potentially lead to a more clinically relevant interpretation of SPV values, thus improving upon current clinical methods for assessing blood volume. This study takes a first step towards identifying SPV influencers by investigating three variations of an existing pressure-flow cardiovascular model. Each successive version introduces an additional modification in attempt to model SPV under normovolemic and hypovolemic conditions, where the last model accounts for positive pressure ventilation, venous compression, and a rightward septum shift. Under normovolemic conditions, each model yields SPV values of 5.8, 6.4, and 6.7 mmHg, respectively. Under hypovolemic conditions the results do not agree with clinical findings, suggesting these three mechanisms alone do not dictate the clinical SPV response to a decrease in volume. Model results are used to suggest improvements for future work.

  19. High-pressure resistivity technique for quasi-hydrostatic compression experiments.

    PubMed

    Rotundu, C R; Ćuk, T; Greene, R L; Shen, Z-X; Hemley, Russell J; Struzhkin, V V

    2013-06-01

    Diamond anvil cell techniques are now well established and powerful methods for measuring materials properties to very high pressure. However, high pressure resistivity measurements are challenging because the electrical contacts attached to the sample have to survive to extreme stress conditions. Until recently, experiments in a diamond anvil cell were mostly limited to non-hydrostatic or quasi-hydrostatic pressure media other than inert gases. We present here a solution to the problem by using focused ion beam ultrathin lithography for a diamond anvil cell loaded with inert gas (Ne) and show typical resistivity data. These ultrathin leads are deposited on the culet of the diamond and are attaching the sample to the anvil mechanically, therefore allowing for measurements in hydrostatic or nearly hydrostatic conditions of pressure using noble gases like Ne or He as pressure transmitting media.

  20. Pressure-Induced Foaming of Metals

    NASA Astrophysics Data System (ADS)

    García-Moreno, Francisco; Mukherjee, Manas; Jiménez, Catalina; Banhart, John

    2015-05-01

    Pressure-induced foaming (PIF) of metals is a foaming technique in which blowing agent free compacted metal powders are foamed. The method consists of heating hot-compacted metallic precursors to above their melting temperature under gas overpressure and foaming them by pressure release. This study focuses on PIF of Al99.7 and AlSi7 alloys under both air or Ar and overpressures up to 9 bar. In situ x-ray radioscopy allows us to follow the foaming process and to perform quantitative analyses of expansion, foam morphology, and coalescence rate. Mass spectrometry helps to identify hydrogen as the foaming gas. Adsorbates on the former powder particles are found to be the primary gas source. Various advantages of this new method are identified and discussed.

  1. On the wetting properties of human stratum corneum epidermidis surface exposed to cold atmospheric-pressure pulsed plasma

    NASA Astrophysics Data System (ADS)

    Athanasopoulos, D.; Svarnas, P.; Ladas, S.; Kennou, S.; Koutsoukos, P.

    2018-05-01

    The Stratum corneum is the outermost layer of the skin, acting as a protective barrier of the epidermis, and its surface properties are directly related to the spreading of topically applied drugs and cosmetics. Numerous works have been devoted to the wettability of this layer over the past 70 years, but, despite the extensive application of atmospheric-pressure plasmas to dermatology, stratum corneum wettability with respect to plasma-induced species has never been considered. The present report assesses the treatment of human stratum corneum epidermidis by atmospheric-pressure pulsed cold plasma-jets for various time intervals and both chemical and morphological modifications are probed. The increase and saturation of the surface free energy due to functionalization are demonstrated, whereas prolonged treatment leads to tissue local disruption (tissue integrity is lost, and stratum corneum looks exfoliated, porous, and even thermally damaged). The latter point arises skepticism about the common practice of contacting atmospheric-pressure plasmas with skin without any previous precautions since the lost skin surface integrity may allow the penetration of pathogenic microorganisms.

  2. 46 CFR 154.452 - External pressure.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ...: P1=the vacuum relief valve setting for tanks with a vacuum relief valve, or 24.5 kPa gauge (3.55 psig) for tanks without a vacuum relief valve. P2=0, or the pressure relief valve setting for an enclosed... weight of the tank, including corrosion allowance, weight of insulation, weight of dome, weight of pipe...

  3. 46 CFR 154.452 - External pressure.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ...: P1=the vacuum relief valve setting for tanks with a vacuum relief valve, or 24.5 kPa gauge (3.55 psig) for tanks without a vacuum relief valve. P2=0, or the pressure relief valve setting for an enclosed... weight of the tank, including corrosion allowance, weight of insulation, weight of dome, weight of pipe...

  4. 46 CFR 154.452 - External pressure.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ...: P1=the vacuum relief valve setting for tanks with a vacuum relief valve, or 24.5 kPa gauge (3.55 psig) for tanks without a vacuum relief valve. P2=0, or the pressure relief valve setting for an enclosed... weight of the tank, including corrosion allowance, weight of insulation, weight of dome, weight of pipe...

  5. 46 CFR 154.452 - External pressure.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ...: P1=the vacuum relief valve setting for tanks with a vacuum relief valve, or 24.5 kPa gauge (3.55 psig) for tanks without a vacuum relief valve. P2=0, or the pressure relief valve setting for an enclosed... weight of the tank, including corrosion allowance, weight of insulation, weight of dome, weight of pipe...

  6. 46 CFR 154.452 - External pressure.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ...: P1=the vacuum relief valve setting for tanks with a vacuum relief valve, or 24.5 kPa gauge (3.55 psig) for tanks without a vacuum relief valve. P2=0, or the pressure relief valve setting for an enclosed... weight of the tank, including corrosion allowance, weight of insulation, weight of dome, weight of pipe...

  7. Polydimethylsiloxane pressure sensors for force analysis in tension band wiring of the olecranon.

    PubMed

    Zens, Martin; Goldschmidtboeing, Frank; Wagner, Ferdinand; Reising, Kilian; Südkamp, Norbert P; Woias, Peter

    2016-11-14

    Several different surgical techniques are used in the treatment of olecranon fractures. Tension band wiring is one of the most preferred options by surgeons worldwide. The concept of this technique is to transform a tensile force into a compression force that adjoins two surfaces of a fractured bone. Currently, little is known about the resulting compression force within a fracture. Sensor devices are needed that directly transduce the compression force into a measurement quality. This allows the comparison of different surgical techniques. Ideally the sensor devices ought to be placed in the gap between the fractured segments. The design, development and characterization of miniaturized pressure sensors fabricated entirely from polydimethylsiloxane (PDMS) for a placement within a fracture is presented. The pressure sensors presented in this work are tested, calibrated and used in an experimental in vitro study. The pressure sensors are highly sensitive with an accuracy of approximately 3 kPa. A flexible fabrication process for various possible applications is described. The first in vitro study shows that using a single-twist or double-twist technique in tension band wiring of the olecranon has no significant effect on the resulting compression forces. The in vitro study shows the feasibility of the proposed measurement technique and the results of a first exemplary study.

  8. Quantitative PLIF Imaging in High-Pressure Combustion

    NASA Technical Reports Server (NTRS)

    Hanson, R. K.

    1997-01-01

    This is the final report for a research project aimed at developing planar laser-induced fluorescence (PLIF) techniques for quantitative 2-D species imaging in fuel-lean, high-pressure combustion gases, relevant to modem aircraft gas turbine combustors. The program involved both theory and experiment. The theoretical activity led to spectroscopic models that allow calculation of the laser-induced fluorescence produced in OH, NO and 02 for arbitrary excitation wavelength, pressure, temperature, gas mixture and laser linewidth. These spectroscopic models incorporate new information on line- broadening, energy transfer and electronic quench rates. Extensive calculations have been made with these models in order to identify optimum excitation strategies, particularly for detecting low levels (ppm) of NO in the presence of large 02 mole fractions (10% is typical for the fuel-lean combustion of interest). A promising new measurement concept has emerged from these calculations, namely that excitation at specific wavelengths, together with detection of fluorescence in multiple spectral bands, promises to enable simultaneous detection of both NO (at ppm levels) and 02 or possibly NO, 02 and temperature. Calculations have been made to evaluate the expected performance of such a diagnostic for a variety of conditions and choices of excitation and detection wavelengths. The experimental effort began with assembly of a new high-pressure combustor to provide controlled high-temperature and high-pressure combustion products. The non-premixed burner enables access to postflame gases at high temperatures (to 2000 K) and high pressures (to 13 atm), and a range of fuel-air equivalence ratios. The chamber also allowed use of a sampling probe, for chemiluminescent detection of NO/NO2, and thermocouples for measurement of gas temperature. Experiments were conducted to confirm the spectroscopic models for OH, NO and 02.

  9. Transient but not sustained blood pressure increments by occupational noise. An ambulatory blood pressure measurement study.

    PubMed

    Fogari, R; Zoppi, A; Corradi, L; Marasi, G; Vanasia, A; Zanchetti, A

    2001-06-01

    Studies on the effects of chronic exposure to industrial noise on clinic blood pressure (BP) at rest have yielded inconsistent results. The aim of this study was to evaluate the effect of occupational noise exposure on ambulatory blood pressure (ABP) in normotensive subjects. We studied 476 normotensive workers, aged 20-50 years (systolic blood pressure (SBP) < 140, diastolic blood pressure (DBP) < 90), at a metallurgical factory; 238 were exposed to high levels of noise (> 85 dB), while 238 were not exposed (< 80 dB). Clinical evaluation included measurements of casual BP (by standard mercury sphygmomanometer, Korotkoff sound phase I and V) and heart rate (HR) (by pulse palpation), body height and weight. All subjects underwent a 24 h non-invasive ABP monitoring (by SpaceLabs 90207 recorder; SpaceLabs, Redmond, Washington, USA) twice within 14 days: one during a normal working day and one during a non-working day. Measurements were performed every 15 min. Computed analysis of individual recordings provided average SBP, DBP and HR values for 24 h, daytime working hours (0800-1700 h), daytime non-working hours (1700-2300 h) and night-time (2300-0800 h). No significant difference in clinic SBP, DBP and HR was observed between exposed and non-exposed subjects. Results obtained by ABP monitoring showed in the exposed workers: (a) a higher SBP (by a mean of 6 mmHg, P < 0.0001 versus controls) and DBP (by a mean of 3 mmHg, P < 0.0001) during the time of exposure and the following 2 or 3 h, whereas no difference between the two groups was found during the non-working day; (b) an increase in HR, which was present not only during the time of exposure to noise (+3.7 beats-per-minute (bpm), P < 0.0001 versus controls), but also during the non-working hours (+2.8 bpm, P < 0.001) and during the day-time hours of the non-working day (+2.8 bpm, P < 0.003); (c) a significant increase in BP variability throughout the working day. These findings suggest that in normotensive subjects

  10. Constant-Differential-Pressure Two-Fluid Accumulator

    NASA Technical Reports Server (NTRS)

    Piecuch, Benjamin; Dalton, Luke T.

    2010-01-01

    A two-fluid accumulator has been designed, built, and demonstrated to provide an acceptably close approximation to constant differential static pressure between two fluids over the full ranges of (1) accumulator stroke, (2) rates of flow of the fluids, and (3) common static pressure applied to the fluids. Prior differential- pressure two-fluid accumulators are generally not capable of maintaining acceptably close approximations to constant differential pressures. The inadequacies of a typical prior differential-pressure two-fluid accumulator can be summarized as follows: The static differential pressure is governed by the intrinsic spring rate (essentially, the stiffness) of an accumulator tank. The spring rate can be tailored through selection of the tank-wall thickness, selection of the number and/or shape of accumulator convolutions, and/or selection of accumulator material(s). Reliance on the intrinsic spring rate of the tank results in three severe limitations: (1) The spring rate and the expulsion efficiency tend to be inversely proportional to each other: that is to say, as the stiffness (and thus the differential pressure) is increased, the range of motion of the accumulator is reduced. (2) As the applied common static pressure increases, the differential pressure tends to decrease. An additional disadvantage, which may or may not be considered limiting, depending on the specific application, is that an increase in stiffness entails an increase in weight. (3) The additional weight required by a low expulsion efficiency accumulator eliminates the advantage given to such gas storage systems. The high expulsion efficiency provided by this two-fluid accumulator allows for a lightweight, tightly packaged system, which can be used in conjunction with a fuel cell-based system.

  11. Ultra-high speed OCT allows measurement of intraocular pressure, corneal geometry, and corneal stiffness using a single instrument

    NASA Astrophysics Data System (ADS)

    Singh, Manmohan; Han, Zhaolong; Nair, Achuth; Schill, Alexander; Twa, Michael D.; Larin, Kirill V.

    2018-02-01

    Screening for ocular diseases, such as glaucoma and keratoconus, includes measuring the eye-globe intraocular pressure (IOP) and corneal biomechanical properties. However, currently available clinical tools cannot quantify corneal tissue material parameters, which can provide critical information for detecting diseases and evaluating therapeutic outcomes. Here, we demonstrate measurement of eye-globe IOP, corneal elasticity, and corneal geometry of in situ porcine corneas with a technique termed applanation optical coherence elastography (Appl-OCE) with single instrument. We utilize an ultrafast phase-sensitive optical coherence tomography system comprised of a 4X buffered Fourier domain mode-locked swept source laser with an Ascan rate of 1.5 MHz and a 7.3 kHz resonant scanner. The IOP was measured by imaging the response of in situ porcine corneas to a large force air-puff. As with other noncontact tonometers, the time when the cornea was applanated during the inwards and outwards motion was correlated to a measure air-pressure temporal profile. The IOP was also measured with a commercially available rebound tonometer for comparison. The stiffness of the corneas was assessed by directly imaging and analyzing the propagation of a focused micro air-pulse induced elastic wave, and the corneal geometry was obtained from the OCT structural image. Our results show that corneal thickness decreased as IOP increased, and that corneal stiffness increased with IOP. Moreover, the IOP measurements made by Appl-OCE were more closely correlated with the artificially set IOP than the rebound tonometer, demonstrating the capabilities of Appl-OCE to measure corneal stiffness, eye-globe IOP, and corneal geometry with a single instrument.

  12. Work, work-life conflict and health in an industrial work environment.

    PubMed

    Hämmig, O; Bauer, G F

    2014-01-01

    Work-life conflict has been poorly studied as a cause of ill-health in occupational medicine. To study associations between physical and psychosocial working conditions, including work-life conflict on the one hand and general, physical and mental health outcomes on the other. Cross-sectional data were used from an employee survey among the workforces of four medium-sized and large companies in Switzerland. Physical work factors included five demands and exposures such as heavy loads, repetitive work and poor posture. Psychosocial factors included 14 demands and limited resources such as time pressure, overtime, monotonous work, job insecurity, low job autonomy, low social support and work-life conflict. Health outcomes studied were self-rated health, sickness absence, musculoskeletal disorders, sleep disorders, stress and burnout. There was a response rate of 49%; 2014 employees participated. All adverse working conditions were positively associated with several poor health outcomes in both men and women. After mutual adjustment for all work factors and additional covariates, only a few, mainly psychosocial work factors remained significant as risk factors for health. Work-life conflict, a largely neglected work-related psychosocial factor in occupational medicine, turned out to be the only factor that was significantly and strongly associated with all studied health outcomes and was consistently found to be the strongest or second strongest of all the studied risk factors. Even in an industrial work environment, psychosocial work factors, and particularly work-life conflict, play a key role and need to be taken into consideration in research and workplace health promotion.

  13. Melting probes revisited - Ice penetration experiments under Mars surface pressure conditions

    NASA Astrophysics Data System (ADS)

    Kömle, Norbert I.; Tiefenbacher, Patrick; Weiss, Peter; Bendiukova, Anastasiia

    2018-07-01

    Melting probes as vehicles to explore terrestrial ice sheets have been designed and applied successfully since the early 1960's. Later on, in the 1990's, various proposals were made to apply such probes also as a means to explore ice sheets on other bodies of the solar system, e.g. Jupiter's icy satellite Europa or the ice caps of Mars. For this type of subsurface probes the name cryobot has become common. We review both early developments and more recent efforts to develop probes for application in planetary environments, i.e. under low pressures and low temperatures. The current state of art as well as the pros and cons of the different concepts hitherto considered are described. While many tests with various probes have been done in terrestrial environments, experiments under low surface pressure conditions are rare. Therefore, we report here on lab tests with a simple melting probe under the range of pressure and temperature conditions that would be encountered on the surface of Mars and compare them with corresponding tests under a much lower gas pressure, possibly representative for icy satellites. The contribution of evaporation during the melting and its variation with surface pressure is also considered. All surface pressure measurements that have been performed on Mars up to now indicate a surface pressure above the water triple point pressure (612 Pa). This means that water ice always transforms into the liquid phase when warmed up to 0°C, before it evaporates into the ambient atmosphere. The temporary existence of the liquid phase around the heated tip of the cryobot allows good thermal conductance between probe and surrounding ice, which is an important pre-requisite for efficient melt penetration. Our experiments indicate that under all possible Mars surface pressures the liquid phase is present when the probe is heated up. This finding confirms experimentally that a probe as it was proposed by Paige (1992) for in situ exploration of the Mars north

  14. Electrochemical removal of material from metallic work

    DOEpatents

    Csakvary, Tibor; Fromson, Robert E.

    1980-05-13

    Deburring, polishing, surface forming and the like are carried out by electrochemical machining with conformable electrode means including an electrically conducting and an insulating web. The surface of the work to be processed is covered by a deformable electrically insulating web or cloth which is perforated and conforms with the work. The web is covered by a deformable perforated electrically conducting screen electrode which also conforms with, and is insulated from, the work by the insulating web. An electrolyte is conducted through the electrode and insulating web and along the work through a perforated elastic member which engages the electrode under pressure pressing the electrode and web against the work. High current under low voltage is conducted betwen the electrode and work through the insulator, removing material from the work. Under the pressure of the elastic member, the electrode and insulator continue to conform with the work and the spacing between the electrode and work is maintained constant.

  15. High-Pressure-Driven Reversible Dissociation of α-Synuclein Fibrils Reveals Structural Hierarchy.

    PubMed

    Piccirilli, Federica; Plotegher, Nicoletta; Ortore, Maria Grazia; Tessari, Isabella; Brucale, Marco; Spinozzi, Francesco; Beltramini, Mariano; Mariani, Paolo; Militello, Valeria; Lupi, Stefano; Perucchi, Andrea; Bubacco, Luigi

    2017-10-17

    The analysis of the α-synuclein (aS) aggregation process, which is involved in Parkinson's disease etiopathogenesis, and of the structural feature of the resulting amyloid fibrils may shed light on the relationship between the structure of aS aggregates and their toxicity. This may be considered a paradigm of the ground work needed to tackle the molecular basis of all the protein-aggregation-related diseases. With this aim, we used chemical and physical dissociation methods to explore the structural organization of wild-type aS fibrils. High pressure (in the kbar range) and alkaline pH were used to disassemble fibrils to collect information on the hierarchic pathway by which distinct β-sheets sequentially unfold using the unique possibility offered by high-pressure Fourier transform infrared spectroscopy. The results point toward the formation of kinetic traps in the energy landscape of aS fibril disassembly and the presence of transient partially folded species during the process. Since we found that the dissociation of wild-type aS fibrils by high pressure is reversible upon pressure release, the disassembled molecules likely retain structural information that favors fibril reformation. To deconstruct the role of the different regions of aS sequence in this process, we measured the high-pressure dissociation of amyloids formed by covalent chimeric dimers of aS (syn-syn) and by the aS deletion mutant that lacks the C-terminus, i.e., aS (1-99). The results allowed us to single out the role of dimerization and that of the C-terminus in the complete maturation of fibrillar aS. Copyright © 2017 Biophysical Society. Published by Elsevier Inc. All rights reserved.

  16. Left Atrial Pressure Monitoring With an Implantable Wireless Pressure Sensor After Implantation of a Left Ventricular Assist Device

    PubMed Central

    Baranowski, Jacek; Delshad, Baz; Ahn, Henrik

    2017-01-01

    After implantation of a continuous-flow left ventricular assist device (LVAD), left atrial pressure (LAP) monitoring allows for the precise management of intravascular volume, inotropic therapy, and pump speed. In this case series of 4 LVAD recipients, we report the first clinical use of this wireless pressure sensor for the long-term monitoring of LAP during LVAD support. A wireless microelectromechanical system pressure sensor (Titan, ISS Inc., Ypsilanti, MI) was placed in the left atrium in four patients at the time of LVAD implantation. Titan sensor LAP was measured in all four patients on the intensive care unit and in three patients at home. Ramped speed tests were performed using LAP and echocardiography in three patients. The left ventricular end-diastolic diameter (cm), flow (L/min), power consumption (W), and blood pressure (mm Hg) were measured at each step. Measurements were performed over 36, 84, 137, and 180 days, respectively. The three discharged patients had equipment at home and were able to perform daily recordings. There were significant correlations between sensor pressure and pump speed, LV and LA size and pulmonary capillary wedge pressure, respectively (r = 0.92–0.99, p < 0.05). There was no device failure, and there were no adverse consequences of its use. PMID:27676410

  17. Thermodynamic models for bounding pressurant mass requirements of cryogenic tanks

    NASA Technical Reports Server (NTRS)

    Vandresar, Neil T.; Haberbusch, Mark S.

    1994-01-01

    Thermodynamic models have been formulated to predict lower and upper bounds for the mass of pressurant gas required to pressurize a cryogenic tank and then expel liquid from the tank. Limiting conditions are based on either thermal equilibrium or zero energy exchange between the pressurant gas and initial tank contents. The models are independent of gravity level and allow specification of autogenous or non-condensible pressurants. Partial liquid fill levels may be specified for initial and final conditions. Model predictions are shown to successfully bound results from limited normal-gravity tests with condensable and non-condensable pressurant gases. Representative maximum collapse factor maps are presented for liquid hydrogen to show the effects of initial and final fill level on the range of pressurant gas requirements. Maximum collapse factors occur for partial expulsions with large final liquid fill fractions.

  18. Nitromethane decomposition under high static pressure.

    PubMed

    Citroni, Margherita; Bini, Roberto; Pagliai, Marco; Cardini, Gianni; Schettino, Vincenzo

    2010-07-29

    The room-temperature pressure-induced reaction of nitromethane has been studied by means of infrared spectroscopy in conjunction with ab initio molecular dynamics simulations. The evolution of the IR spectrum during the reaction has been monitored at 32.2 and 35.5 GPa performing the measurements in a diamond anvil cell. The simulations allowed the characterization of the onset of the high-pressure reaction, showing that its mechanism has a complex bimolecular character and involves the formation of the aci-ion of nitromethane. The growth of a three-dimensional disordered polymer has been evidenced both in the experiments and in the simulations. On decompression of the sample, after the reaction, a continuous evolution of the product is observed with a decomposition into smaller molecules. This behavior has been confirmed by the simulations and represents an important novelty in the scene of the known high-pressure reactions of molecular systems. The major reaction product on decompression is N-methylformamide, the smallest molecule containing the peptide bond. The high-pressure reaction of crystalline nitromethane under irradiation at 458 nm was also experimentally studied. The reaction threshold pressure is significantly lowered by the electronic excitation through two-photon absorption, and methanol, not detected in the purely pressure-induced reaction, is formed. The presence of ammonium carbonate is also observed.

  19. [Development of a continuous blood pressure monitoring and recording system].

    PubMed

    Zhang, Yang; Li, Yong; Gao, Shumei; Song, Yilin

    2012-09-01

    A small experimental system is constructed with working principle of continuous blood pressure monitoring based on the volume compensation method. The preliminary experimental results show that the system can collect blood pressure signals at the radial artery effectively. The digital PID algorithm can track the variation of blood pressure. And the accuracy of continuous blood pressure detecting achieve the level of same kind of product.

  20. Pressure profiles of sport compression stockings.

    PubMed

    Reich-Schupke, Stefanie; Surhoff, Stefan; Stücker, Markus

    2016-05-01

    While sport compression stockings (SCS) have become increasingly popular, there is no regulatory norm as exists for medical compression stockings (MCS). The objective of this pilot study was to compare five SCS with respect to their pressure profiles ex vivo and in vivo, and in relation to German standards for MCS (RAL norm). In vivo (10 competitive athletes; standardized procedure using the Kikuhime pressure monitor) and ex vivo (tested at the Hohenstein Institute) pressure profiles were tested for the following products: CEP Running Progressive Socks, Falke Running Energizing, Sigvaris Performance, X-Socks Speed Metal Energizer, and 2XU Compression Race Socks. Ex vivo ankle pressures of CEP (25.6 mmHg) and 2XU (23.2 mmHg) corresponded to class 2 MCS; that of Sigvaris (20.8 mmHg), to class 1 MCS. The remaining SCS achieved lower pressure values. The pressure gradients showed marked differences, and did not meet MCS standards. Average in vivo pressures were higher for 2XU, CEP, and Sigvaris than for Falke and X-Socks. However, in vivo values for all SCS were below those of class 1 MCS. None of the SCS showed the decreasing pressure gradient (from distal to proximal) required for MCS. In vivo and ex vivo pressure profiles of all SCS examined showed marked heterogeneity, and did not meet MCS standards. Consequently, the clinical and practical effects of SCS cannot be compared, either. It would therefore be desirable to establish a classification that allows for the categorization and comparison of various SCS as well as their selection based on individual preferences and needs (high vs. low pressure, progressive vs. degressive profile). © 2016 Deutsche Dermatologische Gesellschaft (DDG). Published by John Wiley & Sons Ltd.