Sample records for colour doppler ultrasonography

  1. Prenatal diagnosis of placenta accreta by colour Doppler ultrasonography: 5-year review.

    PubMed

    Pongrojpaw, Densak; Chanthasenanont, Athita; Nanthakomon, Tongta; Suwannarurk, Komsun

    2014-08-01

    To determine the accuracy of colour Doppler ultrasonography to diagnose placenta accreta. The authors reviewed cases of placenta accreta between January, 2008 and December, 2012. Ultrasonographic images consistent with signs ofplacenta accreta (numerous vascular lacunae, loss ofsubplacentalsonolucent space, absent lower uterine segment between bladder-placenta, turbulent or complicated blood flow at the uteroplacental interface) were correlated with findings at the time of surgery and pathologic examination. Over 60 months, 12 cases (0.48/1,000 deliveries) with suspected placenta accreta by ultrasonography were studied. The median gestational age atfirst diagnosis was 24 weeks. All cases had at least one previous cesarean delivery. At surgery, all cases had an adherent placenta requiring hysterectomy (five accreta, three increta, andfourpercreta). Four cases (33%) had accidental tear of urinary bladder Nine cases (75%) required blood transfusions. Colour Doppler ultrasonography appears useful in antenatal diagnosis ofplacenta accreta.

  2. Use of colour Doppler and M-mode ultrasonography to confirm the location of an epidural catheter - a retrospective case series.

    PubMed

    Elsharkawy, Hesham; Sonny, Abraham; Govindarajan, Srinivasa Raghavan; Chan, Vincent

    2017-05-01

    Epidural anesthesia and analgesia has a reported failure rate ranging from 13% to 32%. We describe a technique using colour Doppler and M-mode ultrasonography to determine the position of the epidural catheter after placement in adults. This retrospective review included 37 adult patients who received postoperative epidural analgesia and underwent technically difficult epidural catheter placement. The demographic characteristics, type of surgery, use of ultrasonography, method of insertion, intervertebral level, and success of epidural localization using colour Doppler were noted for each patient. Pain scores on postoperative day 1 and the presence of a patchy block were also reviewed. Colour Doppler study helped to indicate the catheter's path from the skin to the epidural space during saline injection in 33 patients (89%). Saline flow within the epidural space (catheter tip confirmation) was successfully detected with colour Doppler in 25 patients (67.5%) and with M-mode ultrasonography in 28 patients (75%). Appropriate dermatomal analgesia was noted in 35 patients (94.5%) during local anesthetic infusion. Our preliminary data suggest the feasibility of using colour Doppler and M-mode ultrasonography to confirm proper epidural catheter placement.

  3. Colour Doppler and microbubble contrast agent ultrasonography do not improve cancer detection rate in transrectal systematic prostate biopsy sampling.

    PubMed

    Taverna, Gianluigi; Morandi, Giovanni; Seveso, Mauro; Giusti, Guido; Benetti, Alessio; Colombo, Piergiuseppe; Minuti, Francesco; Grizzi, Fabio; Graziotti, Pierpaolo

    2011-12-01

    What's known on the subject? and What does the study add? Transrectal gray-scale ultrasonography guided prostate biopsy sampling is the method for diagnosing prostate cancer (PC) in patients with an increased prostate specific antigen level and/or abnormal digital rectal examination. Several imaging strategies have been proposed to optimize the diagnostic value of biopsy sampling, although at the first biopsy nearly 10-30% of PC still remains undiagnosed. This study compares the PC detection rate when employing Colour Doppler ultransongraphy with or without the injection of SonoVue™ microbubble contrast agent, versus the transrectal ultrasongraphy-guided systematic biopsy sampling. The limited accuracy, sensitivity, specificity and the additional cost of using the contrast agent do not justify its routine application in PC detection. • To compare prostate cancer (PC) detection rate employing colour Doppler ultrasonography with or without SonoVue™ contrast agent with transrectal ultrasonography-guided systematic biopsy sampling. • A total of 300 patients with negative digital rectal examination and transrectal grey-scale ultrasonography, with PSA values ranging between 2.5 and 9.9 ng/mL, were randomized into three groups: 100 patients (group A) underwent transrectal ultrasonography-guided systematic bioptic sampling; 100 patients (group B) underwent colour Doppler ultrasonography, and 100 patients (group C) underwent colour Doppler ultrasonography before and during the injection of SonoVue™. • Contrast-enhanced targeted biopsies were sampled into hypervascularized areas of peripheral, transitional, apical or anterior prostate zones. • All the patients included in Groups B and C underwent a further 13 systematic prostate biopsies. The cancer detection rate was calculated for each group. • In 88 (29.3%) patients a histological diagnosis of PC was made, whereas 22 (7.4%) patients were diagnosed with high-grade prostatic intraepithelial

  4. [Color Doppler ultrasonography--a new imaging procedure in maxillofacial surgery].

    PubMed

    Reinert, S; Lentrodt, J

    1991-01-01

    Colour Doppler ultrasonography shows blood flow in real time and colour by combining the features of real time B mode ultrasound and Doppler. At each point in the image the returning signal is interrogated for both amplitude and frequency information. The resulting image shows all non-moving structures in shades of gray and moving structures in shades of red or blue depending on direction and velocity. The technique of colour Doppler ultrasonography and our experiences in 63 examinations are described. The clinical application of this new simple non-invasive method in maxillo-facial surgery is discussed.

  5. Clinical utility of colour flow Doppler ultrasonography in planning anterolateral thigh flap harvest.

    PubMed

    Patel, Rajan S; Higgins, Kevin M; Enepekides, Danny J; Hamilton, Paul A

    2010-10-01

    The anatomic variability of cutaneous perforators contributes to the technical challenges of anterolateral thigh (ALT) free flap harvest. The objective of this study was to assess the accuracy and clinical utility of preoperative colour flow Doppler (CFD) ultrasonography in evaluating planned ALT flap donor sites. A prospective study of the infrainguinal vasculature (profunda femoris and lateral circumflex femoral arteries) in 16 consecutive patients scheduled for ALT free flap transfer for reconstruction of head and neck surgical defects was undertaken. All patients underwent CFD ultrasonography. The location of perforators and the thigh thickness determined by CFD ultrasonography were correlated with the actual intraoperative findings using a scatter plot and paired t-test. Two patients were diagnosed with bilateral silent infrainguinal claudication, which precluded safe use of the ALT donor site. In two other patients, the planned ALT donor site ipsilateral to the defect was not used because of silent infrainguinal claudication diagnosed by CFD ultrasonography. In the 14 patients who underwent ALT flap harvest, CFD ultrasonography identified 48 perforators, which coincided with 43 actual perforators found intraoperatively. CFD ultrasonography demonstrated a statistically significant correlation with the actual perforator locations (Spearman coefficient .76; p = .55). Although CFD ultrasonography tended to underestimate flap thickness, there was a statistically significant correlation (Spearman coefficient .94; p ≤ .0001) with the actual flap thickness. CFD ultrasonography has clinical utility in facilitating decision making and planning ALT flap harvest.

  6. Doppler ultrasonography of the anterior knee tendons in elite badminton players: colour fraction before and after match.

    PubMed

    Koenig, M J; Torp-Pedersen, S; Boesen, M I; Holm, C C; Bliddal, H

    2010-02-01

    Anterior knee tendon problems are seldom reported in badminton players although the game is obviously stressful to the lower extremities. Painful anterior knee tendons are common among elite badminton players. The anterior knee tendons exhibit colour Doppler activity. This activity increases after a match. Painful tendons have more Doppler activity than tendons without pain. Cohort study. 72 elite badminton players were interviewed about training, pain and injuries. The participants were scanned with high-end ultrasound equipment. Colour Doppler was used to examine the tendons of 64 players before a match and 46 players after a match. Intratendinous colour Doppler flow was measured as colour fraction (CF). The tendon complex was divided into three loci: the quadriceps tendon, the proximal patellar tendon and the insertion on the tibial tuberosity. Interview: Of the 72 players, 62 players had problems with 86 tendons in the lower extremity. Of these 86 tendons, 48 were the anterior knee tendons. Ultrasound: At baseline, the majority of players (87%) had colour Doppler flow in at least one scanning position. After a match, the percentage of the knee complexes involved did not change. CF increased significantly in the dominant leg at the tibial tuberosity; single players had a significantly higher CF after a match at the tibial tuberosity and in the patellar tendon both before and after a match. Painful tendons had the highest colour Doppler activity. Most elite badminton players had pain in the anterior knee tendons and intratendinous Doppler activity both before and after match. High levels of Doppler activity were associated with self-reported ongoing pain.

  7. Colour Doppler Ultrasonography as a Tool to Assess Luteal Function in Santa Inês Ewes.

    PubMed

    Figueira, L M; Fonseca, J F; Arashiro, Ekn; Souza-Fabjan, Jmg; Ribeiro, Acs; Oba, E; Viana, Jhm; Brandão, F Z

    2015-08-01

    The aim of this study was to evaluate luteal dynamics in the Santa Inês ewes using colour Doppler (CD) ultrasonography. Oestrus was synchronized in nulliparous females (n = 18), and subsequently, they were only teased (n = 6) or teased and mated (n = 12). Blood samples were collected daily for plasma progesterone (P4 ) concentrations. Ultrasonographic images of corpora lutea (CL) in CD mode were obtained for further analysis in its largest diameter. The CD mode allowed an early sequential monitoring of CL that was visualized by the first time 0.77 ± 0.62 days after ovulation, with luteal area 29.68 ± 13.21 mm(2) . During the luteogenesis, a progressive increase was observed, followed by a plateau of luteal area, vascularization area and plasma concentrations of P4 reaching maximum values in D11 (124.0 ± 38.0 mm(2) , 52.78 ± 24.08 mm(2) and 11.23 ± 4.89 ng/ml, respectively). In the luteolysis, the plasma concentrations of P4 decreased sharply, whereas luteal and vascularization area gradually. The vascularization area was positively correlated with plasma concentrations of P4 during the luteogenesis (r = 0.22) and luteolysis (r = 0.48). The luteal dynamics of Santa Inês ewes showed patterns similar to those observed in other sheep breeds studied. The CD ultrasonography has the potential to be used as a tool to assess luteal function in sheep. © 2015 Blackwell Verlag GmbH.

  8. Preoperative discrimination between malignant and benign adnexal masses with transvaginal ultrasonography and colour blood flow imaging.

    PubMed

    Sawicki, W; Spiewankiewicz, B; Cendrowski, K; Stelmachów, J

    2001-01-01

    Ovarian cancer is one of the causes of death in women, and in about 70% of cases is recognized only in advanced stages. This study was undertaken to evaluate distinctive values of transvaginal and color Doppler ultrasonography in differentiating malignant and benign adnexal masses through analysis of ultrasonic morphological features of malignancy and estimation of location and intensification of angiogenesis as well as values of resistance of flow in examined masses. 329 women with malignant and benign adnexal masses underwent ultrasonographic and colour Doppler examination 1-5 days before surgery (laparotomy, laparoscopy) thus allowing histological verification of diagnosis. The ultrasonographic structure was assessed using a morphological scoring system devised by Sassone, Jain and Benacerraf. Regions showing vasculature, especially within septae and solid parts of tumours were examined by means of transvaginal colour Doppler. Location and intensification of angiogenesis as well as resistance index (RI) were investigated. Sensitivity, specificity, PPV and NPV of both techniques were assessed. Statistical analysis of obtained data were based on the Student's t test; p < 0.05 level was considered significant. Postoperatively 255 (77.5%) benign and 74 (22.5%) malignant tumours were seen. In the group of benign masses the average age of women was 42.6+/-12.3 and in the malignant it was 53.1+/-12.6 (p<0.0001). The transverse dimension of benign lesions was 77.2+/-19, whereas for malignant it was 107.0+/-31 (p<0.0001). Benign tumours in 63.0% were cystic, in 26.0% mixed cystic-solid and in 11.0% solid echostructures while in malignant they were respectively, 6.8%, 56.8% and 36.4% (p<0.0001). Doppler flow within the tumour was 74.5% in benign and 98.6% in malignant masses (p<0.0001). In benign lesions homogenous superficial or peripheral vasculature was visualized, and in the majority of cases (82.7%) it was of medium intensification. However in malignant central

  9. Carotid artery Doppler ultrasonography in retinal macroaneurysms.

    PubMed

    Thurairajan, G; Potamitis, T; Naylor, G; Gibson, J

    1998-01-01

    It is postulated that retinal arterial macroaneurysms (RAMs) occur at the site of incomplete embolic occlusion of a branch retinal artery. Embolic events of the retinal vessels are related to the state of the carotid artery tree and therefore Doppler ultrasonography of the carotid arteries in these patients is of particular interest. We have examined 13 patients with retinal artery macroaneurysms with carotid artery Doppler ultrasonography (CADU). Eight of these patients (61.5%) exhibited atheromatous plaques on the same side as the RAM with a moderate degree of arterial narrowing. Although our group of patients did not show advanced carotid artery disease, alterations of the arterial wall found at the level of the carotid artery were higher than expected in a similar hypertensive population. To our knowledge this is the first study of the carotid arterial tree in these patients. Our results support the theory that RAMs may be of embolic origin. Furthermore they demonstrate that CADU is a useful investigation in patients with RAMs.

  10. Doppler ultrasonography and single-fiber laser Doppler flowmetry for measurement of hind limb blood flow in anesthetized horses.

    PubMed

    Raisis, A L; Young, L E; Taylor, P M; Walsh, K P; Lekeux, P

    2000-03-01

    To use Doppler ultrasonography and single-fiber laser Doppler flowmetry (LDF) to evaluate blood flow in the dependent and nondependent hind limbs of anesthetized horses and to evaluate changes in femoral arterial blood flow and microvascular skeletal muscle perfusion in response to administration of phenylephrine hydrochloride or dobutamine hydrochloride. 6 healthy adult horses. Horses were anesthetized and positioned in left lateral recumbency. Doppler ultrasonography was used to measure velocity and volumetric flow in the femoral vessels. Single-fiber LDF was used to measure relative microvascular perfusion at a single site in the semimembranosus muscles. Phenylephrine or dobutamine was then administered to decrease or increase femoral arterial blood flow, and changes in blood flow and microvascular perfusion were recorded. Administration of phenylephrine resulted in significant decreases in femoral arterial and venous blood flows and cardiac output and significant increases in mean aortic blood pressure, systemic vascular resistance, and PCV. Administration of dobutamine resulted in significant increases in femoral arterial blood flow, mean aortic blood pressure, and PCV. Significant changes in microvascular perfusion were not detected. Results suggest that Doppler ultrasonography and single-fiber LDF can be used to study blood flows in the hind limbs of anesthetized horses. However, further studies are required to determine why changes in femoral arterial blood flows were not associated with changes in microvascular perfusion.

  11. Doppler ultrasonography of the pectinis oculi artery in harpy eagles (Harpia harpyja)

    PubMed Central

    de Moraes, Wanderlei; Ferreira, Thiago A.C.; Somma, André T.; Cubas, Zalmir S.; Moore, Bret A.; Montiani-Ferreira, Fabiano

    2017-01-01

    Twenty harpy eagles (Harpia harpyja) without systemic or ocular diseases were examined to measure blood velocity parameters of the pectinis oculi artery using Doppler ultrasonography. Pectinate artery resistive index (RI) and pulsatility index (PI) were investigated using ocular Doppler ultrasonography. The mean RI and PI values across all eyes were 0.44±0.10 and 0.62±0.20 respectively. Low RI and PI values found in the harpy eagle´s pectinis oculi artery compared with the American pekin ducks one and other tissue suggest indeed a high metabolic activity in pecten oculi and corroborates the hypothesis of a nutritional function and/or intraocular pressure regulation. PMID:28540254

  12. Ultrasonography with color Doppler and power Doppler in the diagnosis of periapical lesions

    PubMed Central

    Goel, Sumit; Nagendrareddy, Suma Gundareddy; Raju, Manthena Srinivasa; Krishnojirao, Dayashankara Rao Jingade; Rastogi, Rajul; Mohan, Ravi Prakash Sasankoti; Gupta, Swati

    2011-01-01

    Aim: To evaluate the efficacy of ultrasonography (USG) with color Doppler and power Doppler applications over conventional radiography in the diagnosis of periapical lesions. Materials and Methods: Thirty patients having inflammatory periapical lesions of the maxillary or mandibular anterior teeth and requiring endodontic surgery were selected for inclusion in this study. All patients consented to participate in the study. We used conventional periapical radiographs as well as USG with color Doppler and power Doppler for the diagnosis of these lesions. Their diagnostic performances were compared against histopathologic examination. All data were compared and statistically analyzed. Results: USG examination with color Doppler and power Doppler identified 29 (19 cysts and 10 granulomas) of 30 periapical lesions accurately, with a sensitivity of 100% for cysts and 90.91% for granulomas and a specificity of 90.91% for cysts and 100% for granulomas. In comparison, conventional intraoral radiography identified only 21 lesions (sensitivity of 78.9% for cysts and 45.4% for granulomas and specificity of 45.4% for cysts and 78.9% for granulomas). There was definite correlation between the echotexture of the lesions and the histopathological features except in one case. Conclusions: USG imaging with color Doppler and power Doppler is superior to conventional intraoral radiographic methods for diagnosing the nature of periapical lesions in the anterior jaws. This study reveals the potential of USG examination in the study of other jaw lesions. PMID:22223940

  13. Practical application of color Doppler ultrasonography in patients with ejaculatory dysfunction.

    PubMed

    Hara, Ryoei; Nagai, Atsushi; Fujii, Tomohiro; Fukumoto, Kazuhiko; Ohira, Shin; Jo, Yoshimasa; Yokoyama, Teruhiko; Miyaji, Yoshiyuki

    2015-06-01

    We describe two cases in which dynamic analysis of ejaculation using color Doppler ultrasonography was useful in diagnosis of ejaculatory dysfunction and planning of therapy. The first patient was a 32-year-old man with a diagnosis of retrograde ejaculation. A bladder neck collagen injection was carried out, as the main cause was thought to be the bladder neck remaining open during ejaculation. The patient had antegrade ejaculation 1 week later. The second patient was a 48-year-old man with a diagnosis of anorgasmia accompanied by decreased seminal emission and insufficient function of the rhythmic pelvic striated muscles. The patient was prescribed etilefrine hydrochloride 15 mg/day. The symptom improved 2 weeks after starting this drug. These cases suggest that the use of color Doppler ultrasonography during ejaculation can improve the understanding of ejaculatory dysfunction and therapy for this condition. © 2015 The Japanese Urological Association.

  14. B-mode and power Doppler ultrasonography of the equine suspensory ligament branches: A descriptive study on 13 horses.

    PubMed

    Rabba, Silvia; Grulke, Sigrid; Verwilghen, Denis; Evrard, Laurence; Busoni, Valeria

    2018-03-01

    Ultrasonography is routinely used to achieve the diagnosis of equine suspensory ligament desmopathy. In human medicine, power Doppler ultrasonography has also been found to be useful for the diagnosis of tendon/ligament injuries. The aim of this prospective, pilot study was to assess the presence or absence of power Doppler signal in suspensory ligament branches and compare B-mode findings with power Doppler findings in suspensory ligament branches of lame and non-lame limbs. Thirteen horses were used (eight lame horses, with lameness related to pain in the suspensory ligament branches, and five non-lame horses). Ten lame limbs and 24 sound limbs were assessed by B-mode and power Doppler ultrasonography. The severity of power Doppler signal was scored by two independent readers. The B-mode ultrasonographic examination revealed abnormalities in branches of lame limbs and in branches of sound limbs. Suspensory ligament branches that were considered normal in B-mode showed no power Doppler signal. However, power Doppler signal was detected in suspensory ligament branches that were abnormal in B-mode, both in lame and sound limbs. Power Doppler scores were subjectively higher in suspensory ligament branches of lame limbs and in branches with more severe B-mode changes. Findings supported the use of power Doppler as an adjunctive diagnostic test for lame horses with suspected suspensory desmopathy. © 2018 American College of Veterinary Radiology.

  15. The efficacy of real-time colour Doppler flow imaging on endoscopic ultrasonography for differential diagnosis between neoplastic and non-neoplastic gallbladder polyps.

    PubMed

    Kim, Su Young; Cho, Jae Hee; Kim, Eui Joo; Chung, Dong Hae; Kim, Kun Kuk; Park, Yeon Ho; Kim, Yeon Suk

    2018-05-01

    We evaluated the usefulness of real-time colour Doppler flow (CDF) endoscopic ultrasonography (EUS) for differentiating neoplastic gallbladder (GB) polyps from non-neoplastic polyps. Between August 2014 and December 2016, a total of 233 patients with GB polyps who underwent real-time CDF-EUS were consecutively enrolled in this prospective study. CDF imaging was subjectively categorized for each patient as: strong CDF pattern, weak CDF pattern and no CDF pattern. Of the 233 patients, 115 underwent surgical resection. Of these, there were 90 cases of non-neoplastic GB polyps and 23 cases of neoplastic GB polyps. In a multivariate analysis, a strong CDF pattern was the most significant predictive factor for neoplastic polyps; sensitivity, specificity, positive predictive value, negative predictive value and accuracy were 52.2 %, 79.4 %, 38.7 %, 86.9 % and 73.9 %, respectively. Solitary polyp and polyp size were associated with an increased risk of neoplasm. The presence of a strong CDF pattern as well as solitary and larger polyps on EUS may be predictive of neoplastic GB polyps. As real-time CDF-EUS poses no danger to the patient and requires no additional equipment, it is likely to become a supplemental tool for the differential diagnosis of GB polyps. • Differential diagnosis between neoplastic polyps and non-neoplastic polyps of GB is limited. • The use of real-time CDF-EUS was convenient, with high agreement between operators. • The real-time CDF-EUS is helpful in differential diagnosis of GB polyps.

  16. High-definition flow Doppler ultrasonographic technique to assess hepatic vasculature compared with color or power Doppler ultrasonography: preliminary experience.

    PubMed

    Kim, Se Hyung; Lee, Jeong Min; Kim, Young Jun; Lee, Jae Young; Han, Joon Koo; Choi, Byung Ihn

    2008-10-01

    The purpose of this study was to introduce a new high-definition flow (HDF) Doppler technique and to compare its performance with those of color Doppler ultrasonography (CDU) and power Doppler ultrasonography (PDU) for assessment of hepatic vasculature in native and transplanted livers. High-definition flow was invented as a high-resolution bidirectional PDU technique. We obtained CDU, PDU, and HDF images of the hepatic artery (HA), portal vein (PV), and hepatic vein from 60 patients. They were divided into 2 groups: a liver transplantation group (group 1, n = 10) and a native liver group (group 2, n = 50). Two radiologists independently reviewed the cine images and graded them using a 4-point scale in terms of the clarity of the vessel margin and degree of depiction of the HA, flow filling, and flash artifacts. The degree of differentiation between the HA and PV was also evaluated. Flow directionality was recorded, and interobserver agreement was finally analyzed. Moderate to almost perfect agreement was achieved between radiologists for all parameters of each ultrasonographic technique. High-definition flow was significantly superior to both CDU and PDU with respect to all analyzed items except the degree of flash artifacts (P < .05). With regard to flash artifacts, CDU was significantly better than either PDU or HDF. High-definition flow provided directional information, as did CDU. The HDF technique provides better resolution for depicting hepatic vessels as well as their margins with less blooming compared with conventional Doppler ultrasonography in both native and transplanted liver. It also provides solid directional flow information. One point of concern, however, is the frequency of flash artifacts compared with that on CDU.

  17. Blood flow in intracranial aneurysms treated with Pipeline embolization devices: computational simulation and verification with Doppler ultrasonography on phantom models

    PubMed Central

    2015-01-01

    Purpose: The aim of this study was to validate a computational fluid dynamics (CFD) simulation of flow-diverter treatment through Doppler ultrasonography measurements in patient-specific models of intracranial bifurcation and side-wall aneurysms. Methods: Computational and physical models of patient-specific bifurcation and sidewall aneurysms were constructed from computed tomography angiography with use of stereolithography, a three-dimensional printing technology. Flow dynamics parameters before and after flow-diverter treatment were measured with pulse-wave and color Doppler ultrasonography, and then compared with CFD simulations. Results: CFD simulations showed drastic flow reduction after flow-diverter treatment in both aneurysms. The mean volume flow rate decreased by 90% and 85% for the bifurcation aneurysm and the side-wall aneurysm, respectively. Velocity contour plots from computer simulations before and after flow diversion closely resembled the patterns obtained by color Doppler ultrasonography. Conclusion: The CFD estimation of flow reduction in aneurysms treated with a flow-diverting stent was verified by Doppler ultrasonography in patient-specific phantom models of bifurcation and side-wall aneurysms. The combination of CFD and ultrasonography may constitute a feasible and reliable technique in studying the treatment of intracranial aneurysms with flow-diverting stents. PMID:25754367

  18. Doppler ultrasonography in living donor liver transplantation recipients: Intra- and post-operative vascular complications

    PubMed Central

    Abdelaziz, Omar; Attia, Hussein

    2016-01-01

    Living-donor liver transplantation has provided a solution to the severe lack of cadaver grafts for the replacement of liver afflicted with end-stage cirrhosis, fulminant disease, or inborn errors of metabolism. Vascular complications remain the most serious complications and a common cause for graft failure after hepatic transplantation. Doppler ultrasound remains the primary radiological imaging modality for the diagnosis of such complications. This article presents a brief review of intra- and post-operative living donor liver transplantation anatomy and a synopsis of the role of ultrasonography and color Doppler in evaluating the graft vascular haemodynamics both during surgery and post-operatively in accurately defining the early vascular complications. Intra-operative ultrasonography of the liver graft provides the surgeon with useful real-time diagnostic and staging information that may result in an alteration in the planned surgical approach and corrections of surgical complications during the procedure of vascular anastomoses. The relevant intra-operative anatomy and the spectrum of normal and abnormal findings are described. Ultrasonography and color Doppler also provides the clinicians and surgeons early post-operative potential developmental complications that may occur during hospital stay. Early detection and thus early problem solving can make the difference between graft survival and failure. PMID:27468207

  19. Routine preoperative colour Doppler duplex ultrasound scanning in anterolateral thigh flaps.

    PubMed

    Lichte, Johanna; Teichmann, Jan; Loberg, Christina; Kloss-Brandstätter, Anita; Bartella, Alexander; Steiner, Timm; Modabber, Ali; Hölzle, Frank; Lethaus, Bernd

    2016-10-01

    The anterolateral thigh flap (ALT) is often used to reconstruct the head and neck and depends on one or more skin perforators, which often present with variable anatomy. The aim of this study was to localise and evaluate the precise position of these perforators preoperatively with colour Doppler duplex ultrasound scanning (US). We detected 74 perforators in 30 patients. The mean duration of examination with colour Doppler was 29 (range 13-51) minutes. Adequate perforators and their anatomical course could be detected preoperatively extremely accurately (p<0.001). The mean difference between the preoperatively marked, and the real, positions was 6.3 (range 0-16) mm. There was a highly significant correlation between the accuracy of the prediction and the body mass index of the patient (0.75; p<0.001). Neither the age nor the sex of the patient correlated with the accuracy of the prediction. Colour Doppler duplex US used preoperatively to localise perforators in ALT flaps is reliable and could be adopted as standard procedure. Copyright © 2016 The British Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  20. Comprasion of ovarian stromal blood flow measured by color Doppler ultrasonography in polycystic ovary syndrome patients and healthy women with ultrasonographic evidence of polycystic.

    PubMed

    Ozdemir, Ozhan; Sari, Mustafa Erkan; Kalkan, Dilek; Koc, Esra Meltem; Ozdemir, Seyda; Atalay, Cemal Resat

    2015-04-01

    To compare ovarian stromal artery blood flows measured by Doppler ultrasonography of polycystic ovary syndrome (PCOS) patients and healthy women with polycystic ovarian image in ultrasonography. Forty-two patients diagnosed with PCOS according to the criteria of 2003 Rotterdam Concencus Conferance on PCOS and 38 healthy volunteers with polycystic ovarian image in ultrasonography were included in the study. Ovarian volumes and ovarian stromal artery blood flows were measured by 3-dimensional (3-D) ultrasonography and Doppler ultrasonography in all patients. In patients with PCOS, ovarian stromal artery pulsatility index (PI) and resistivity index (RI) were found significantly different from healthy women with polycystic ovarian image in ultrasonography (p < 0.05). 3-D ovarian volumes were found significantly higher in patients with PCOS (p < 0.05), and a negative correlation was also obtained between ovarian volumes and ovarian stromal artery resistivity indices. Ovarian stromal artery Doppler examination could have an importance to explain the pathophysiology of PCOS, but there are few publications in the literature about PCOS and the details of ovarian stromal artery Doppler parameters in patients with polycystic ovarian image only. We conclude that Doppler ultrasonography findings of PCOS patients might be helpful in understanding the clinical follow-up and etiology of the disease.

  1. Evaluation of joint effusion in rabbits by color Doppler, power Doppler, and contrast-enhanced power Doppler ultrasonography.

    PubMed

    Lim, Gye-Yeon; Im, Soo Ah; Jung, Won Sang; Lee, Jae Mun; Lee, Ah Won

    2005-09-01

    The aim of this prospective study was to evaluate the diagnostic value of power Doppler ultrasonography (PDUS) and contrast-enhanced PDUS (CEPDUS) in the depiction and characterization of experimentally induced arthritis in the rabbit. Thirty rabbits were divided into three groups consisting of one control group (saline injection group) and two experimental groups: a suppurative arthritis group and a chemically induced synovitis group. The same amount (1 ml) of each agent was directly injected into the right hip joint. Serial color Doppler ultrasound (CDUS), PDUS, and CEPDUS images were obtained before and after injection. We observed that all of the infected knees in the suppurative arthritis group with Staphylococcus aureus demonstrated an increased signal on PDUS after inoculation. A minimal power Doppler signal was presented in the chemically induced synovitis group with talc injection, but none of the control knees demonstrated any increased signals. CEPDUS was the most sensitive imaging modality for evaluating the increase of blood flows in suppurative arthritis and was subsequently followed by PDUS and CDUS. The increased signals obtained with PDUS represent increased local blood flows; therefore, this technique can be used for evaluating the degree of inflammation. Furthermore, using the contrast agent enhances the sensitivity of PDUS, and it can even be useful for differentiating borderline cases. Copyright 2005 Wiley Periodicals, Inc

  2. Value of doppler ultrasonography in the study of hemodialysis peripheral vascular access dysfunction.

    PubMed

    Moreno Sánchez, T; Martín Hervás, C; Sola Martínez, E; Moreno Rodríguez, F

    2014-01-01

    The main objectives of this study were to evaluate the sensitivity and specificity of duplex Doppler ultrasonography in the study of hemodialysis peripheral vascular access dysfunction and to analyze the resistance index and flow in the afferent artery. We prospectively studied 178 patients with 178 peripheral vascular accesses that were dysfunctional in at least three consecutive hemodialysis sessions. Patients underwent duplex Doppler ultrasonography and clinical and laboratory follow-up for three months (provided angiography findings were negative). We calculated the sensitivity, specificity, predictive values, and coefficients of probability. We studied the morphology of the afferent artery, the arteriovenous anastomosis, and the efferent vein, and we measured the resistance index and the flow of the afferent artery, the diameter of the anastomosis, and the flow and peak systolic velocity in the efferent vein. The final sample consisted of 159 patients. The sensitivity, specificity, positive and negative predictive values, and positive and negative coefficients of probability were 0,98 (95% CI: 0,88-1.00), 0,74 (95% CI: 0,66-0,81), 0,96, 0,82, 3.7, and 0,03, respectively. The resistance index was less than 0,5 in 78.5% of the peripheral vascular accesses with normal function and greater than 0,5 in 86.1% of the dysfunctional peripheral vascular accesses. We found aneurysms in 19 of the native peripheral vascular accesses and pseudoaneurysms in 7 of the prosthetic grafts. Inverted flow was seen in 57 peripheral vascular accesses. Duplex Doppler ultrasonography is an efficacious method for detecting and characterizing stenosis and thrombosis in peripheral vascular accesses, and it provides information about the morphology and hemodynamics. Copyright © 2012 SERAM. Published by Elsevier Espana. All rights reserved.

  3. Diagnosis of post-partum ovarian vein thrombophlebitis by color Doppler ultrasonography: about 10 cases.

    PubMed

    Giraud, J R; Poulain, P; Renaud-Giono, A; Darnault, J P; Proudhon, J F; Grall, J Y; Mocquet, P Y

    1997-09-01

    Post-partum ovarian vein thrombosis is often overlooked or mistaken for other complications such as endometritis. Color Doppler ultrasonography is a very good diagnostic method when properly indicated and correctly interpreted according to clinical data. This study reports ten cases that were retrospectively studied, during which color Doppler ultrasonography was used. The clinical signs and the results are reviewed. The lesions were clearly visualized in eight of the ten cases; one of the two failures resulted from a methodological fault (uninterpretable result); the other one was due to the lack of experience of the operator and nonrecognition of the clinical signs. Thrombosis appears as a hypoechogenic and tubular image. This type of examination is particularly indicated in the presence of certain clinical signs that were observed in our cases: fever and iliac pain are the main precursor signs, often associated with abdominal meteorism and slow digestive transit; provoked cul-de-sac pain during vaginal probing was the only constant sign, sometimes associated with painful swelling.

  4. Grey-scale and colour Doppler ultrasound versus magnetic resonance imaging for the prenatal diagnosis of placenta accreta.

    PubMed

    Rezk, Mohamed Abd-Allah; Shawky, Mohamed

    2016-01-01

    To assess the effectiveness of grey-scale and colour Doppler ultrasound (US) versus magnetic resonance imaging (MRI) for the prenatal diagnosis of placenta accreta. A prospective observational study including a total of 74 patients with placenta previa and previous uterine scar (n = 74). Grey-scale and colour Doppler US was done followed by MRI by different observers to diagnose adherent placenta. Test validity of US and MRI were calculated. Maternal morbidity and mortality were also assessed. A total of 53 patients confirmed to have placenta accreta at operation. The overall sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of US was 94.34, 91.67, 96.15 and 88% compared to 96.08, 87.50, 94.23 and 91.3% for MRI, respectively. The most relevant US sign was turbulent blood flow by colour Doppler, while dark intra-placental band was the most sensitive MRI sign. Venous thromboembolism (1.3%), bladder injury (29.7%), ureteric injury (18.9%), postoperative fever (10.8%), admission to ICU (50%) and re-operation (31.1%). Placenta accreta can be successfully diagnosed by grey-scale and colour Doppler US. MRI would be more likely suggested for either posteriorly or laterally situated placenta previa in order to exclude placental invasion.

  5. [The diagnostic performance of color Doppler ultrasonography for newborn four cases of midgut volvulus accompanied by intestinal malrotation].

    PubMed

    Ikeshima, Yukari; Hisano, Katsuya; Morisawa, Takeshi; Inoue, Kozue; Shimamoto, Masahiro; Koujitani, Toshiaki; Yonetani, Masahiko; Yasufuku, Masao

    2014-03-01

    Midgut volvulus accompanied by intestinal malrotation is classified as a surgical emergency disease of the newborn, which emerges with the bilious vomiting or melena. This report presents four patients of this disease in our hospital, evaluated by color Doppler ultrasonography before surgical operation. All four patients were presented by bilious vomiting at the onset. By color Doppler ultrasonography method, the whirlpool sign which is the view of intestine and superior mesenteric vein rotated around with the axis of superior mesenteric artery, were shown in all cases. This whirlpool sign led to the diagnosis of midgut volvulus accompanied by intestinal malrotation. Intestinal contrast imaging was tested in three patients for the purpose of confirming the diagnosis. Repair of the volvulus and a ladd operation was performed in all four patients, without the excision of intestine because of no intestinal ischemic change. The clinical courses of four cases were good, and all patients were discharged within 17 days. Early diagnosis and timely surgical operation are essential for decreasing the possibility of occurring intestinal ischemic changes and improving clinical outcome after surgical operation. We propose that color Doppler ultrasonography is the powerful tool for the diagnosis of this disease, especially for the newborn, for whom the available diagnostic tests are limited.

  6. [The role of ultrasonography in the investigation of male infertility].

    PubMed

    Fejes, Zsuzsanna; Pásztor, Norbert; Karczagi, Lilla; Brzózka, Ádám; Király, István; Morvay, Zita; Palkó, András

    2018-05-01

    Unintended childlessness affects approximately 9-15% of couples in the reproductive age. It is known that a remarkable proportion of infertility is caused by the disorders of the male reproductive functions. Diagnostic imaging methods and especially ultrasonography play a crucial role in the infertility work-up, the ultrasound examination has become the method of choice for imaging in diseases affecting the testis. With the development of high resolution transducers and technology using colour Doppler, pulsed Doppler, share wave elastography and strain elastography, it is now possible to make accurate diagnoses. However, the place of the new imaging methods in the algorithm of infertility check-up should be clearly defined. Orv Hetil. 2018; 159(21): 815-822.

  7. Evaluation of the Causes of Erectile Dysfunction in Patients Undergoing Penile Doppler Ultrasonography in Pakistan

    PubMed Central

    Khanzada, Usman; Khan, Sohail Ahmed; Hussain, Munawar; Adel, Hatem; Masood, Kamran; Manohar, Murli

    2017-01-01

    Purpose In patients with erectile dysfunction, it is important to differentiate psychogenic from organic causes. Penile Doppler ultrasonography is a relatively inexpensive and minimally invasive tool for this purpose. This study was conducted to evaluate the causes of erectile dysfunction in an adult male population, using penile Doppler ultrasonography. Materials and Methods A retrospective study was conducted in a single center. All patients who presented with complaints of erectile dysfunction and underwent penile Doppler ultrasonography between July 2014 and June 2016 were included in this study. All examinations were performed using GE Voluson S6 and GE Logiq P5 devices. Following baseline scans, an intracavernosal injection of 20 µg of prostaglandin E1 was given. Peak systolic and end diastolic velocities were measured in each cavernosal artery. Patients with a peak systolic velocity of <25 cm/s were considered to have arterial insufficiency, while an end diastolic velocity of >5 cm/s was considered to indicate venous incompetence. Results Out of 97 patients (mean age, 37.09±11.59 years; range, 19~69 years), 50 patients (51.5%) had normal findings, 24 patients (24.7%) had arterial insufficiency, 15 patients (15.5%) had a venous leak, and 8 patients (8.2%) patients had arterial insufficiency with a venous leak. Psychogenic erectile dysfunction was significantly higher among patients aged ≤40 years, while arterial insufficiency with or without a venous leak was significantly higher among patients aged >40 years (p=0.022). Conclusions A majority of the studied individuals demonstrated no organic cause of erectile dysfunction, thus confirming a high prevalence of the psychogenic etiology, particularly in relatively young individuals. PMID:28459144

  8. A Comparative Study on Quantitative Assessment of Blood Flow and Vascularization in Polycystic Ovary Syndrome Patients and Normal Women Using Three-Dimensional Power Doppler Ultrasonography.

    PubMed

    Garg, Nitasha; Khaira, Harkiran Kaur; Kaur, Manjot; Sinha, Smita

    2018-04-01

    To compare the quantitative assessment of blood flow and vascularization of ovaries in polycystic ovary syndrome patients and normal women using three-dimensional power Doppler ultrasonography. This cross-sectional quantitative study was conducted on women of reproductive age group (15-45 years) attending Gynaecology OPD AIMSR, Bathinda, Punjab. Thirty women were enrolled in polycystic ovarian syndrome (PCOS) group and 30 healthy women in control group. Women were categorized as polycystic ovary syndrome according to Rotterdam's criteria. The women with PCOS underwent transvaginal USG Doppler on day 6 of the cycle using 3D power Doppler USG equipment (GE Voluson E8), and vascularization index (VI), flow index (FI) and vascularization flow index (VFI) were measured. The mean values of VI, FI and VFI measured by power Doppler ultrasonography were significantly increased ( P value = 0.000) in women with PCOS when compared with healthy women. This study suggests that blood flow and vascularization measured by 3D power Doppler ultrasonography in ovaries of polycystic ovary syndrome patients were significantly more than the ovaries of normal women.

  9. Evaluation of gastrointestinal activity patterns in healthy horses using B mode and Doppler ultrasonography

    PubMed Central

    2005-01-01

    Abstract Healthy adult horses were examined by using transabdominal ultrasonography to quantitatively and qualitatively evaluate activity of the jejunum, cecum, and colon with B mode and Doppler techniques. Doppler ultrasound was used to assess jejunal peristaltic activity. Examinations were performed on multiple occasions under imposed colic evaluation conditions, including fasting, nasogastric intubation, and xylazine sedation. In fasted horses, jejunal visibility was increased and jejunal, cecal, and colonic activity was decreased. The stomach was displaced ventrally and was visualized ventral to the costochondral junction. Xylazine sedation in fed horses had minimal effects; however, in fasted horses, xylazine significantly decreased jejunal and cecal activity. Nasogastric intubation in fasted horses had no observable effects on activity, but moved the stomach dorsally. B mode and Doppler jejunal activity were strongly correlated. Prior feeding and sedation status need to be considered when interpreting the results of equine abdominal ultrasound examinations. Doppler techniques may be useful for assessing jejunal activity. PMID:15825515

  10. [Intraoperative ultrasonography during laparoscopic surgery].

    PubMed

    Alecu, L; Lungu, C; Pascu, A; Costan, I; Corodeanu, G; Deacu, A; Marin, A

    2000-01-01

    Of this study is the introduction and the results evaluation of laparoscopic ultrasonography performed. We realize a prospective study about laparoscopic ultrasonography performed in 37 cases with laparoscopic surgical treatment. The Aloka SSD 2000 mobile scanner is used. This system make possible the use of an linear-array transducer, with mechanical flexibility and availability of Doppler analysis. Most frequently we used intraoperative ultrasonography in laparoscopic cholecystectomy as an alternative for cholangiography to exclude CBD pathology. Because of various surgical pathology with laparoscopic approach, the laparoscopic ultrasonography utilization range was vastly. In all the cases we could performed the laparoscopic ultrasonography. In 6 of 27 cases with laparoscopic cholecystectomy we found pathological disorders of bile ducts. CBD with diameter found between 5-12 mm. We properly saw the distal segment of CBD in 23 cases (89.2%), and common hepatic duct in 26 cases (97.3%). The quality of visualization was very good in 21 cases (83.8%) and moderate in 6 cases (16.2%). We easy identify CBD stones and we successfully used Doppler color mode in differentiating vascular from non-vascular from non-vascular structures. Laparoscopic ultrasonography performed in a case with left colon cancer excluded liver metastasis and lymph nodes metastasis. 1. Laparoscopic ultrasonography combines the advantages of diagnostic laparoscopy and intraoperative contact ultrasonography; 2. Laparoscopic ultrasonography is a simple and very efficient intraoperative examination procedure; 3. Laparoscopic ultrasonography is the technique to choose in CBD intraoperative exploration; 4. Laparoscopic ultrasonography improve abdominal malignancy exploration, thus modifying therapeutic decisions; 5. Color Doppler mode guides the surgeon's steps in difficult directions.

  11. Doppler ultrasonography combined with transient elastography improves the non-invasive assessment of fibrosis in patients with chronic liver diseases.

    PubMed

    Alempijevic, Tamara; Zec, Simon; Nikolic, Vladimir; Veljkovic, Aleksandar; Stojanovic, Zoran; Matovic, Vera; Milosavljevic, Tomica

    2017-01-31

    Accurate clinical assessment of liver fibrosis is essential and the aim of our study was to compare and combine hemodynamic Doppler ultrasonography, liver stiffness by transient elastography, and non-invasive serum biomarkers with the degree of fibrosis confirmed by liver biopsy, and thereby to determine the value of combining non-invasive method in the prediction significant liver fibrosis. We included 102 patients with chronic liver disease of various etiology. Each patient was evaluated using Doppler ultrasonography measurements of the velocity and flow pattern at portal trunk, hepatic and splenic artery, serum fibrosis biomarkers, and transient elastography. These parameters were then input into a multilayer perceptron artificial neural network with two hidden layers, and used to create models for predicting significant fibrosis. According to METAVIR score, clinically significant fibrosis (≥F2) was detected in 57.8% of patients. A model based only on Doppler parameters (hepatic artery diameter, hepatic artery systolic and diastolic velocity, splenic artery systolic velocity and splenic artery Resistance Index), predicted significant liver fibrosis with a sensitivity and specificity of75.0% and 60.0%. The addition of unrelated non-invasive tests improved the diagnostic accuracy of Doppler examination. The best model for prediction of significant fibrosis was obtained by combining Doppler parameters, non-invasive markers (APRI, ASPRI, and FIB-4) and transient elastography, with a sensitivity and specificity of 88.9% and 100%. Doppler parameters alone predict the presence of ≥F2 fibrosis with fair accuracy. Better prediction rates are achieved by combining Doppler variables with non-invasive markers and liver stiffness by transient elastography.

  12. A new scoring model for characterization of adnexal masses based on two-dimensional gray-scale and colour Doppler sonographic features

    PubMed Central

    Abbas, A.M.; Zahran, K.M.; Nasr, A.; Kamel, H.S.

    2014-01-01

    Objective: To determine the most discriminating two-dimensional gray-scale and colour Doppler sonographic features that allow differentiation between malignant and benign adnexal masses, and to develop a scoring model that would enable more accurate diagnosis with those features. Methods: A cross sectional prospective study was conducted on patients scheduled for surgery due to presence of adnexal masses at Woman’s Health Center, Assiut University, Egypt between October 2012 and October 2013. All patients were evaluated by 2D ultrasound for morphological features of the masses combined with colour Doppler examination of their vessels. The final diagnosis, based on histopathological analysis, was used as a gold standard. Results: One hundred forty-six patients were recruited, 104 with benign masses, 42 with malignant masses. Features that allowed statistically significant discrimination of benignity from malignancy were; volume of mass, type of mass, presence and thickness of septae, presence and length of papillary projections, location of vessels at colour Doppler and colour score. A scoring model was formulated combining these features together; Assiut Scoring Model (ASM). The cut-off level with the highest accuracy in detection of malignancy, was ≥6, had a sensitivity of 93.5% and specificity of 92.2%. Conclusion: Our Scoring Model; a multiparameter scoring using four gray-scale ultrasound and two colour Doppler features, had shown a high sensitivity and specificity for prediction of malignancy in adnexal masses compared with previous scoring systems. PMID:25009729

  13. Diagnostic Accuracy of B-mode USG and Doppler Scan for Ovarian Lesions

    PubMed Central

    Agarwal, Vinish Kumar

    2016-01-01

    Introduction Ultrasonography (USG) is considered as the primary imaging modality for confirmation of ovarian mass and to differentiate them in to benign or malignant. Aim The present study was conducted with the aim to evaluate accuracy of B- mode USG and Doppler scan (Colour Doppler + Spectral Doppler) for ovarian lesions. Materials and Methods The patients included in the study were from those referred with either palpable adnexal mass or incidentally detected adnexal masses. Total 250 women were evaluated by USG, Doppler scan. Only fifty patients who had true ovarian mass intraoperatively and on histopathology were included in study, rest masses were excluded. Study parameters were morphological indexing on B- Mode USG, flow study, vessel arrangement, and vessel morphology and vessel location in Colour Doppler and resistive index and pulsatility index in spectral Doppler. Results Total 50 women were included in present study. Out of these 46% were pre-menopausal while 54% were menopaused women, 66.7% of post-menopausal women had malignant ovarian masses compared to 8.7% of premenopausal. Sensitivity, specificity, positive predictive value and negative predictive value of B-Mode USG for ovarian masses were 94.44%, 48.15%, 54.84% and 92.86% respectively, with p-value = 0.007, while sensitivity, specificity, positive predictive value and negative predictive value of Doppler scan were 85%, 90%, 85% and 90% respectively, with p-value = 0.0001. Conclusion USG and its different techniques are accepted as the primary imaging modality for early stage diagnosis of an ovarian malignancy. Statistical analysis suggests that Doppler Scan (Colour + Spectral) was more accurate (88%) than B-Mode USG (67%), but author is in view that both of these modalities should be used in conjunction to screen the ovarian lesions. PMID:27790544

  14. Three-dimensional ultrasonography and power Doppler for discrimination between benign and malignant endometrium in premenopausal women with abnormal uterine bleeding.

    PubMed

    El-Sharkawy, Mohamed; El-Mazny, Akmal; Ramadan, Wafaa; Hatem, Dina; Abdel-Hafiz, Aly; Hammam, Mohamed; Nada, Adel

    2016-03-16

    Ultrasonography has been extensively used in women suspected of having a gynecological malignancy. The aim of this study is to evaluate the efficacy of 3D ultrasonography and power Doppler for discrimination between benign and malignant endometrium in premenopausal women with abnormal uterine bleeding. This cross-sectional study included 78 premenopausal women with abnormal uterine bleeding scheduled for hysteroscopy and endometrial curettage. The endometrial thickness (ET), uterine artery pulsatility index (PI) and resistance index (RI), and endometrial volume (EV) and 3D power Doppler vascularization index (VI), flow index (FI), and vascularization flow index (VFI) were measured and compared with hysteroscopic and histopathologic findings. The ET (P <0.001), EV (P <0.001), and endometrial VI (P <0.001) and VFI (P = 0.043) were significantly increased in patients with atypical endometrial hyperplasia and endometrial carcinoma (n = 10) than those with benign endometrium (n = 68); whereas, the uterine artery PI and RI and endometrial FI were not significantly different between the two groups. The best marker for discrimination between benign and malignant endometrium was the VI with an area under the ROC curve of 0.88 at a cutoff value of 0.81%. 3D ultrasonography and power Doppler, especially endometrial VI, may be useful for discrimination between benign and malignant endometrium in premenopausal women with abnormal uterine bleeding.

  15. Clinical use of ultrasonography associated with color Doppler in the diagnosis and follow-up of acute pyelonephritis.

    PubMed

    Dell'Atti, Lucio; Borea, Pier Andrea; Ughi, Gianni; Russo, Gian Rosario

    2010-12-01

    The purpose of this study is to evaluate the current role of the Ultrasound associated with the color-Doppler in the diagnosis of acute pyelonephritis (APN) and to compare ultrasound images with CT images in order to reduce the amount radiation absorbe without significant loss of diagnostic efficacy, since this disease in most cases affects young adults. We studied 38 patients (aged 17-65 years) who presented from September 2007 to March 2010 to the emergency department with suspected diagnosis of APN. All patients underwent first to an ultrasound study, then to abdominal CT. Renal, perirenal and extrarenal tomographic findings usually associated with acute pyelonephritis were analyzed, in an attempt to identify what are the differences with respect to the images obtained with an ultrasound study. All patients then performed ultrasonography and/or abdominal CT evaluation one month later, 25 patients repeated both examinations, while the other 13 repeated only ultrasound. In 38 subjects with suspected APN, CT assessed the presence in 79% and in 21% the absence of the disease. Ultrasonography in 68% of cases diagnosed APN, by an increase in kidney size related to the presence of hypoechoic areas associated to edema, blurred margins and reduction of the color-Doppler vascularity. Ultrasound associated with the use of color-Doppler revealed a sensibility of 76% and specificity of 75%. Color and power-Doppler have better diagnostic accuracy than basic gray scale ultrasound, in the diagnosis of focal pyelonephritis. Therefore the combined use of ultrasound and color-Doppler can obtain useful information about the diagnosis and follow-up of the disease, with an improvement in terms of cost, without significantly altering the diagnostic efficacy and reducing the amount of radiation absorbed.

  16. Transdural doppler ultrasonography monitors cerebral blood flow changes in relation to motor tasks.

    PubMed

    Hatanaka, Nobuhiko; Tokuno, Hironobu; Nambu, Atsushi; Takada, Masahiko

    2009-04-01

    Monitoring changes in cerebral blood flow in association with neuronal activity has widely been used to evaluate various brain functions. However, current techniques do not directly measure blood flow changes in specified blood vessels. The present study identified arterioles within the cerebral cortex by echoencephalography and color Doppler imaging, and then measured blood flow velocity (BFV) changes in pulsed-wave Doppler mode. We applied this "transdural Doppler ultrasonography (TDD)" to examine BFV changes in the cortical motor-related areas of monkeys during the performance of unimanual (right or left) and bimanual key-press tasks. BFV in the primary motor cortex (MI) was increased in response to contralateral movement. In each of the unimanual and bimanual tasks, bimodal BFV increases related to both the instruction signal and the movement were observed in the supplementary motor area (SMA). Such BFV changes in the SMA were prominent during the early stage of task training and gradually decreased with improvements in task performance, leaving those in the MI unchanged. Moreover, BFV changes in the SMA depended on task difficulty. The present results indicate that TDD is useful for evaluating regional brain functions.

  17. The utility of ultrasound superb microvascular imaging for evaluation of breast tumour vascularity: comparison with colour and power Doppler imaging regarding diagnostic performance.

    PubMed

    Park, A Y; Seo, B K; Woo, O H; Jung, K S; Cho, K R; Park, E K; Cha, S H; Cha, J

    2018-03-01

    To investigate the utility of superb microvascular imaging (SMI) for evaluating the vascularity of breast masses in comparison with colour or power Doppler ultrasound (US) and the effect on diagnostic performance. A total of 191 biopsy-proven masses (99 benign and 92 malignant) in 166 women with greyscale, colour Doppler, power Doppler, and SMI images were enrolled in this retrospective study. Three radiologists analysed the vascular images using a three-factor scoring system to evaluate the number, morphology, and distribution of tumour vessels. They assessed the Breast Imaging-Reporting and Data System categories for greyscale US alone and combinations of greyscale US and each type of vascular US. The Kruskal-Wallis test was performed and the area under the receiver-operating characteristic curve (AUC) measured. On SMI, vascular scores were compared between benign and malignant masses and the optimal cut-off value for the overall score was determined. SMI showed higher vascular scores than colour or power Doppler US and malignant masses had higher scores than benign masses (p<0.001). The diagnostic performance of the combination of greyscale US and SMI was higher than those of greyscale US alone and greyscale and colour or power Doppler US (AUC, 0.815 versus 0.774, 0.789, 0.791; p<0.001). The optimal cut-off value of the overall vascular score was 5 with a sensitivity of 82.3% and a specificity of 65.3% (AUC, 0.808). SMI is superior to colour or power Doppler US for characterising the vascularity in breast masses and improving diagnostic performance. Copyright © 2017 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  18. Four-dimensional ultrasonography of the fetal heart using color Doppler spatiotemporal image correlation.

    PubMed

    Gonçalves, Luís F; Romero, Roberto; Espinoza, Jimmy; Lee, Wesley; Treadwell, Marjorie; Chintala, Kavitha; Brandl, Helmut; Chaiworapongsa, Tinnakorn

    2004-04-01

    To describe clinical and research applications of 4-dimensional imaging of the fetal heart using color Doppler spatiotemporal image correlation. Forty-four volume data sets were acquired by color Doppler spatiotemporal image correlation. Seven subjects were examined: 4 fetuses without abnormalities, 1 fetus with ventriculomegaly and a hypoplastic cerebellum but normal cardiac anatomy, and 2 fetuses with cardiac anomalies detected by fetal echocardiography (1 case of a ventricular septal defect associated with trisomy 21 and 1 case of a double-inlet right ventricle with a 46,XX karyotype). The median gestational age at the time of examination was 21 3/7 weeks (range, 19 5/7-34 0/7 weeks). Volume data sets were reviewed offline by multiplanar display and volume-rendering methods. Representative images and online video clips illustrating the diagnostic potential of this technology are presented. Color Doppler spatiotemporal image correlation allowed multiplanar visualization of ventricular septal defects, multiplanar display and volume rendering of tricuspid regurgitation, volume rendering of the outflow tracts by color and power Doppler ultrasonography (both in a normal case and in a case of a double-inlet right ventricle with a double-outlet right ventricle), and visualization of venous streams at the level of the foramen ovale. Color Doppler spatiotemporal image correlation has the potential to simplify visualization of the outflow tracts and improve the evaluation of the location and extent of ventricular septal defects. Other applications include 3-dimensional evaluation of regurgitation jets and venous streams at the level of the foramen ovale.

  19. Determination of Testicular Blood Flow in Camelids Using Vascular Casting and Color Pulsed-Wave Doppler Ultrasonography

    PubMed Central

    Kutzler, Michelle; Tyson, Reid; Grimes, Monica; Timm, Karen

    2011-01-01

    We describe the vasculature of the camelid testis using plastic casting. We also use color pulsed-wave Doppler ultrasonography to measure testicular blood flow and compare the differences between testicular blood flow in fertile and infertile camelids. The testicular artery originates from the ventral surface of the aorta, gives rise to an epididymal branch, and becomes very tortuous as it approaches the testis. Within the supratesticular arteries, peak systolic velocity (PSV) was higher in fertile males compared to infertile males (P = 0.0004). In addition, end diastolic velocity (EDV) within the supratesticular arteries was higher for fertile males when compared to infertile males (P = 0.0325). Within the marginal arteries, PSV was also higher in fertile males compared to infertile males (P = 0.0104). However, EDV within the marginal arteries was not significantly different between fertile and infertile males (P = 0.121). In addition, the resistance index was not significantly different between fertile and infertile males within the supratesticular (P = 0.486) and marginal arteries (P = 0.144). The significance of this research is that in addition to information obtained from a complete reproductive evaluation, a male camelid's fertility can be determined using testicular blood flow measured by Doppler ultrasonography. PMID:21941690

  20. Determination of testicular blood flow in camelids using vascular casting and color pulsed-wave Doppler ultrasonography.

    PubMed

    Kutzler, Michelle; Tyson, Reid; Grimes, Monica; Timm, Karen

    2011-01-01

    We describe the vasculature of the camelid testis using plastic casting. We also use color pulsed-wave Doppler ultrasonography to measure testicular blood flow and compare the differences between testicular blood flow in fertile and infertile camelids. The testicular artery originates from the ventral surface of the aorta, gives rise to an epididymal branch, and becomes very tortuous as it approaches the testis. Within the supratesticular arteries, peak systolic velocity (PSV) was higher in fertile males compared to infertile males (P = 0.0004). In addition, end diastolic velocity (EDV) within the supratesticular arteries was higher for fertile males when compared to infertile males (P = 0.0325). Within the marginal arteries, PSV was also higher in fertile males compared to infertile males (P = 0.0104). However, EDV within the marginal arteries was not significantly different between fertile and infertile males (P = 0.121). In addition, the resistance index was not significantly different between fertile and infertile males within the supratesticular (P = 0.486) and marginal arteries (P = 0.144). The significance of this research is that in addition to information obtained from a complete reproductive evaluation, a male camelid's fertility can be determined using testicular blood flow measured by Doppler ultrasonography.

  1. Power Doppler Ultrasonography and Shear Wave Elastography as Complementary Imaging Methods for Suspected Local Breast Cancer Recurrence.

    PubMed

    Jales, Rodrigo Menezes; Dória, Maira Teixeira; Serra, Kátia Piton; Miranda, Mila Meneguelli; Menossi, Carlos Alberto; Schumacher, Klaus; Sarian, Luis Otávio

    2018-06-01

    To prospectively investigate the diagnostic accuracy and clinical consequences of power Doppler morphologic criteria and shear wave elastography (SWE) as complementary imaging methods for evaluation of suspected local breast cancer recurrence in the ipsilateral breast or chest wall. Thirty-two breast masses with a suspicion of local breast cancer recurrence on B-mode ultrasonography underwent complementary power Doppler and SWE evaluations. Power Doppler morphologic criteria were classified as avascular, hypovascular, or hypervascular. Shear wave elastography was classified according to a 5-point scale (SWE score) and SWE maximum elasticity. Diagnostic accuracy was assessed by the sensitivity, specificity, and area under the curve. A decision curve analysis assessed clinical consequences of each method. The reference standard for diagnosis was defined as core needle or excisional biopsy. Histopathologic examinations revealed 9 (28.2%) benign and 23 (71.8%) malignant cases. Power Doppler ultrasonography (US) had sensitivity of 34.8% (95% confidence interval [CI], 6.6%-62.9%) and specificity of 45.4% (95% CI, 19.3%-71.5%). The SWE score (≥3) had sensitivity of 87.0% (95% CI, 66.4%-97.2%) and specificity of 44.4% (95% CI, 13.7%-78.8%). The SWE maximum elasticity (velocity > 6.5cm/s) had sensitivity of 87% (95% CI, 66.4%-97.2%) and specificity of 77.8% (95% CI, 40.0% to 97.2%). The areas under the curves for the SWE score and SWE maximum elasticity were 0.71 (95% CI, 0.53-0.87) and 0.82 (95% CI, 0.64-0.93), respectively (P = .32). Power Doppler US is unsuitable for discrimination between local breast cancer recurrence and fibrosis. Although the SWE score and SWE maximum elasticity can make this discrimination, the use of these methods to determine biopsy may lead to poorer clinical outcomes than the current practice of performing biopsies of all suspicious masses. © 2017 by the American Institute of Ultrasound in Medicine.

  2. Quantification of mitral and tricuspid regurgitation by the proximal flow convergence method using two-dimensional colour Doppler and colour Doppler M-mode: influence of the mechanism of regurgitation.

    PubMed

    Grossmann, G; Giesler, M; Stein, M; Kochs, M; Höher, M; Hombach, V

    1998-10-30

    In patients with mitral (n=77: organic=49, functional=28) and tricuspid regurgitation (n=55: functional=54) quantified by angiography, the temporal variation of the proximal flow convergence region throughout systole was assessed by colour Doppler M-Mode, and peak and mean radius of the proximal isovelocity surface area for 28 cm/s blood flow velocity were measured. Additionally, the peak radius derived from two-dimensional colour Doppler was obtained. About 50% of the patients with mitral and tricuspid regurgitation showed a typical temporal variation of the flow convergence region related to the mechanism of regurgitation. The different proximal isovelocity surface area radii were similarly correlated to the angiographic grade in mitral and tricuspid regurgitation (rank correlation coefficients 0.55-0.89) and they differentiated mild to moderate (grade < or =II) from severe (grade > or =III) mitral and tricuspid regurgitation with comparable accuracy (82-96%). However, moderate mitral regurgitation due to leaflet prolapse in two patients was correctly classified by the mean M-mode radius and overestimated by both peak radii. Only half of the patients showed a typical variation of the flow convergence region related to the mechanism of regurgitation. The different proximal isovelocity surface area radii were suitable to quantify mitral and tricuspid regurgitation in most patients. However, in mitral regurgitation due to leaflet prolapse the use of the mean M-mode radius may avoid overestimation.

  3. [Practical Use of Doppler Ultrasonography of the Cardiovascular System and Clinical Laboratory Tests for the Management of Pulmonary Embolism].

    PubMed

    Mizukami, Naoko

    2015-08-01

    Acute or chronic pulmonary embolism (PE) is a serious disease, and the risk of mortality is increased if untreated. In 90% of cases the embolus source is deep vein thrombosis (DVT) of the lower limbs or pelvic cavity. Therefore, it is necessary to recognize these as venous thromboembolism (VTE) which includes both DVT and PE. I suggest that Doppler ultrasonography of cardiovascular and clinical laboratory tests provide very valuable medical support for the management of VTE. Specifically, in the early diagnosis of VTE and the prevention of fatal PE, Doppler ultrasonography (cardiac and vascular) can provide very useful information. On the other hand, blood coagulation and thrombophilia tests are important to determine the risk of VTE and evaluate the effect of anticoagulant therapy on VTE. In this paper, I explain the main points of each examination of VTE by describing representative cases. I also show the results on investigating cases in our hospital involving diseases related to VTE and the onset site of DVT. In addition, I introduce how we convey the results of analysis to the clinical side.

  4. Assessing the usefulness of B-mode and colour Doppler sonography, and measurements of circulating progesterone concentrations for determining ovarian responses in superovulated ewes.

    PubMed

    Oliveira, Mef; Ribeiro, I F; Rodriguez, Mgk; Maciel, G S; Fonseca, J F; Brandão, F Z; Bartlewski, P M

    2018-06-01

    The main goal of this study was to assess the usefulness of two imaging modalities, namely the B-mode and colour Doppler sonography, and serum progesterone (P 4 ) concentrations for determining the ovarian response in superovulated ewes. Twenty-four sexually mature Santa Inês ewes underwent the superovulatory treatment consisting of eight injections of porcine FSH (total dose of 200 or 133 or 100 mg; n = 8 ewes/total dose) given at 12-hr intervals and initiated 48 hr before CIDR ® (Pfizer Inc., Auckland, New Zealand) removal. Six days after natural mating, the ovaries of all donor ewes were visualized and examined with transrectal ultrasonography and then with videolaparoscopy to identify and enumerate corpora lutea (CL) and luteinized unovulated follicles (LUFs). Jugular blood samples were collected just prior to ovarian examinations. The total number of CL (r = .78 and 0.83, p < .0001) and LUFs (r = .74 and 0.90, p < .0001) enumerated using the B-mode and colour Doppler ultrasonographic technique, respectively, were correlated with that ascertained by videolaparoscopy. Circulating concentrations of P 4 were related directly to the number of healthy CL (r = .73, p = .0002) and inversely to the number of prematurely regressing CL (r = -.46, p = .03), but the accuracy of predicting the number of short-lived CL with serum P 4 concentrations was very poor. The present results indicate that ultrasonographic imaging and serum P 4 measurements on the day of embryo recovery are useful indicators of total/normal CL numbers and both ultrasonographic techniques can be used to quantify LUFs in superovulated ewes. © 2018 Blackwell Verlag GmbH.

  5. Ultrahigh field magnetic resonance and colour Doppler real-time fusion imaging of the orbit--a hybrid tool for assessment of choroidal melanoma.

    PubMed

    Walter, Uwe; Niendorf, Thoralf; Graessl, Andreas; Rieger, Jan; Krüger, Paul-Christian; Langner, Sönke; Guthoff, Rudolf F; Stachs, Oliver

    2014-05-01

    A combination of magnetic resonance images with real-time high-resolution ultrasound known as fusion imaging may improve ophthalmologic examination. This study was undertaken to evaluate the feasibility of orbital high-field magnetic resonance and real-time colour Doppler ultrasound image fusion and navigation. This case study, performed between April and June 2013, included one healthy man (age, 47 years) and two patients (one woman, 57 years; one man, 67 years) with choroidal melanomas. All cases underwent 7.0-T magnetic resonance imaging using a custom-made ocular imaging surface coil. The Digital Imaging and Communications in Medicine volume data set was then loaded into the ultrasound system for manual registration of the live ultrasound image and fusion imaging examination. Data registration, matching and then volume navigation were feasible in all cases. Fusion imaging provided real-time imaging capabilities and high tissue contrast of choroidal tumour and optic nerve. It also allowed adding a real-time colour Doppler signal on magnetic resonance images for assessment of vasculature of tumour and retrobulbar structures. The combination of orbital high-field magnetic resonance and colour Doppler ultrasound image fusion and navigation is feasible. Multimodal fusion imaging promises to foster assessment and monitoring of choroidal melanoma and optic nerve disorders. • Orbital magnetic resonance and colour Doppler ultrasound real-time fusion imaging is feasible • Fusion imaging combines the spatial and temporal resolution advantages of each modality • Magnetic resonance and ultrasound fusion imaging improves assessment of choroidal melanoma vascularisation.

  6. Assessment of early placental development in the cynomolgus monkey (Macaca fascicularis) using colour and pulsed wave Doppler sonography.

    PubMed

    Nimrod, C; Simpson, N; Hafner, T; de Vermette, R; Fournier, J; Coady, L; Baccanale, C

    1996-04-01

    Colour flow mapping and pulsed wave Doppler were used to assess the process of placental growth and development in the cynomolgus monkey from 32 to 71 days gestational age. Fetal and maternal vessels were reliably visualised and insonated. Accurate longitudinal non-invasive assessment of placentation is possible using this technique.

  7. Reliability, validity and feasibility of nail ultrasonography in psoriatic arthritis.

    PubMed

    Arbault, Anaïs; Devilliers, Hervé; Laroche, Davy; Cayot, Audrey; Vabres, Pierre; Maillefert, Jean-Francis; Ornetti, Paul

    2016-10-01

    To determine the feasibility, reliability and validity of nails ultrasonography in psoriatic arthritis as an outcome measure. Pilot prospective single-centre study of eight ultrasonography parameters in B mode and power Doppler concerning the distal interphalangeal (DIP) joint, the matrix, the bed and nail plate. Intra-observer and inter-observer reliability was evaluated for the seven quantitative parameters (ICC and kappa). Correlations between ultrasonography and clinical variables were searched to assess external validity. Feasibility was assessed by the time to carry out the examination and the percentage of missing data. Twenty-seven patients with psoriatic arthritis (age 55.0±16.2 years, disease duration 13.4±9.4 years) were included. Of these, 67% presented nail involvement on ultrasonography vs 37% on physical examination (P<0.05). Reliability was good (ICC and weighted kappa>0.75) for the seven quantitative parameters, except for synovitis of the DIP joint in B mode. The synovitis of the DIP joint revealed by ultrasonography correlated with the total number of clinical synovitis and Doppler US of the nail (matrix and bed). Doppler US of the matrix correlated with VAS pain but not with the ASDAS-CRP or with clinical enthesitis. No significant correlation was found with US nail thickness. The feasibility and reliability of ultrasonography of the nail in psoriatic arthritis appear to be satisfactory. Among the eight parameters evaluated, power Doppler of the matrix which correlated with local inflammation (DIP joint and bed) and with VAS pain could become an interesting outcome measure, provided that it is also sensitive to change. Copyright © 2015 Société française de rhumatologie. Published by Elsevier SAS. All rights reserved.

  8. Assessing hemispheric specialization for processing arithmetic skills in adults: A functional transcranial doppler ultrasonography (fTCD) study.

    PubMed

    Connaughton, Veronica M; Amiruddin, Azhani; Clunies-Ross, Karen L; French, Noel; Fox, Allison M

    2017-05-01

    A major model of the cerebral circuits that underpin arithmetic calculation is the triple-code model of numerical processing. This model proposes that the lateralization of mathematical operations is organized across three circuits: a left-hemispheric dominant verbal code; a bilateral magnitude representation of numbers and a bilateral Arabic number code. This study simultaneously measured the blood flow of both middle cerebral arteries using functional transcranial Doppler ultrasonography to assess hemispheric specialization during the performance of both language and arithmetic tasks. The propositions of the triple-code model were assessed in a non-clinical adult group by measuring cerebral blood flow during the performance of multiplication and subtraction problems. Participants were 17 adults aged between 18-27 years. We obtained laterality indices for each type of mathematical operation and compared these in participants with left-hemispheric language dominance. It was hypothesized that blood flow would lateralize to the left hemisphere during the performance of multiplication operations, but would not lateralize during the performance of subtraction operations. Hemispheric blood flow was significantly left lateralized during the multiplication task, but was not lateralized during the subtraction task. Compared to high spatial resolution neuroimaging techniques previously used to measure cerebral lateralization, functional transcranial Doppler ultrasonography is a cost-effective measure that provides a superior temporal representation of arithmetic cognition. These results provide support for the triple-code model of arithmetic processing and offer complementary evidence that multiplication operations are processed differently in the adult brain compared to subtraction operations. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. Contrast-enhanced color Doppler ultrasonography increases diagnostic accuracy for soft tissue tumors.

    PubMed

    Oebisu, Naoto; Hoshi, Manabu; Ieguchi, Makoto; Takada, Jun; Iwai, Tadashi; Ohsawa, Masahiko; Nakamura, Hiroaki

    2014-10-01

    Resolution of ultrasonography (US) has undergone marked development. Additionally, a new-generation contrast medium (Sonazoid) used for US is newly available. Contrast-enhanced US has been widely used for evaluating several types of cancer. In the present study, we evaluated the ability of color Doppler US (CDUS) and Sonazoid to differentiate between benign and malignant soft tissue tumors. A total of 180 patients (87 male, 93 female) were enrolled in the present study. The patient ages ranged from 1 to 91 years (mean 58.1±20.0 years). The maximum size, depth, tumor margins, shape, echogenicity and textural pattern were measured on gray-scale images. CDUS was used to evaluate the intratumoral blood flow with and without Sonazoid. Peak systolic flow velocity (Vp), mean flow velocity (Vm), resistivity index (RI) and pulsatility index (PI) of each detected intratumoral artery were automatically calculated with power Doppler US (PDUS). The present study included 118 benign and 62 malignant tumors. Statistical significances were found in size, depth, tumor margin and textural pattern but not in shape or echogenicity on gray-scale images. Before Sonazoid injection, CDUS findings showed 55% sensitivity, 77% specificity and 69% accuracy, whereas contrast-enhanced CDUS showed 87% sensitivity, 68% specificity and 74% accuracy. There were no statistically significant differences between malignant and benign tumors regarding the mean Vp, Vm, RI and PI values determined on PDUS. In conclusion, contrast-enhanced CDUS proved to be a reliable diagnostic tool for detecting malignant potential in soft tissue tumors.

  10. The use of the color Doppler ultrasonography in the diagnosis and monitoring of an atypical case of giant-cell arteritis.

    PubMed

    Martins, N; Polido-Pereira, J; Rodrigues, A M; Soares, F; Batista, P; Pereira da Silva, J A

    2016-01-01

    Giant Cell Arteritis (GCA) is a large vessels vasculitis that is typically characterised by headache, scalp tenderness, jaw claudication and visual disturbances. Temporal arteries color Doppler ultrasonography (CDUS) is a sensitive and non-invasive image technique used in the diagnosis of this disease. This work highlights the importance of CDUS in the diagnostic workup of GCA and also demonstrates it´s usefullness in the evaluation and documentation of the response to corticosteroids therapy in an atypical case of ACG.

  11. Evaluation of arterial digital blood flow using Doppler ultrasonography in healthy dairy cows.

    PubMed

    Müller, H; Heinrich, M; Mielenz, N; Reese, S; Steiner, A; Starke, A

    2017-06-06

    Local circulatory disturbances have been implicated in the development of foot disorders in cattle. The goals of this study were to evaluate the suitability of the interdigital artery in the pastern region in both hind limbs using pulsed-wave (PW) Doppler ultrasonography and to investigate quantitative arterial blood flow variables at that site in dairy cows. An Esaote MyLabOne ultrasound machine with a 10-MHz linear transducer was used to assess blood flow in the interdigital artery in the pastern region in both hind limbs of 22 healthy German Holstein cows. The cows originated from three commercial farms and were restrained in a standing hoof trimming chute without sedation. A PW Doppler signal suitable for analysis was obtained in 17 of 22 cows. The blood flow profiles were categorised into four curve types, and the following quantitative variables were measured in three uniform cardiac cycles: vessel diameter, pulse rate, maximum systolic velocity, maximum diastolic velocity, end-diastolic velocity, reverse velocity, maximum time-averaged mean velocity, blood flow rate, resistance index and persistence index. The measurements did not differ among cows from the three farms. Maximum systolic velocity, vessel diameter and pulse rate did not differ but other variables differed significantly among blood flow profiles. Differences in weight-bearing are thought to be responsible for the normal variability of blood flow profiles in healthy cows. The scanning technique used in this report for evaluation of blood flow in the interdigital artery appears suitable for further investigations in healthy and in lame cows.

  12. Is the measurement of inferior thyroid artery blood flow velocity by color-flow Doppler ultrasonography useful for differential diagnosis between gestational transient thyrotoxicosis and Graves' disease? A prospective study.

    PubMed

    Zuhur, Sayid Shafi; Ozel, Alper; Velet, Selvinaz; Buğdacı, Mehmet Sait; Cil, Esra; Altuntas, Yüksel

    2012-01-01

    To determine the role of peak systolic velocity, end-diastolic velocity and resistance indices of both the right and left inferior thyroid arteries measured by color-flow Doppler ultrasonography for a differential diagnosis between gestational transient thyrotoxicosis and Graves' disease during pregnancy. The right and left inferior thyroid artery-peak systolic velocity, end-diastolic velocity and resistance indices of 96 patients with thyrotoxicosis (41 with gestational transient thyrotoxicosis, 31 age-matched pregnant patients with Graves' disease and 24 age- and sex-matched non-pregnant patients with Graves' disease) and 25 age and sex-matched healthy euthyroid subjects were assessed with color-flow Doppler ultrasonography. The right and left inferior thyroid artery-peak systolic and end-diastolic velocities in patients with gestational transient thyrotoxicosis were found to be significantly lower than those of pregnant patients with Graves' disease and higher than those of healthy euthyroid subjects. However, the right and left inferior thyroid artery peak systolic and end-diastolic velocities in pregnant patients with Graves' disease were significantly lower than those of non-pregnant patients with Graves' disease. The right and left inferior thyroid artery peak systolic and end-diastolic velocities were positively correlated with TSH-receptor antibody levels. We found an overlap between the inferior thyroid artery-blood flow velocities in a considerable number of patients with gestational transient thyrotoxicosis and pregnant patients with Graves' disease. This study suggests that the measurement of inferior thyroid artery-blood flow velocities with color-flow Doppler ultrasonography does not have sufficient sensitivity and specificity to be recommended as an initial diagnostic test for a differential diagnosis between gestational transient thyrotoxicosis and Graves' disease during pregnancy.

  13. Is the measurement of inferior thyroid artery blood flow velocity by color-flow Doppler ultrasonography useful for differential diagnosis between gestational transient thyrotoxicosis and Graves' disease? A prospective study

    PubMed Central

    Zuhur, Sayid Shafi; Özel, Alper; Velet, Selvinaz; Buğdacı, Mehmet Sait; Çil, Esra; Altuntas, Yüksel

    2012-01-01

    OBJECTIVE: To determine the role of peak systolic velocity, end-diastolic velocity and resistance indices of both the right and left inferior thyroid arteries measured by color-flow Doppler ultrasonography for a differential diagnosis between gestational transient thyrotoxicosis and Graves' disease during pregnancy. METHODS: The right and left inferior thyroid artery-peak systolic velocity, end-diastolic velocity and resistance indices of 96 patients with thyrotoxicosis (41 with gestational transient thyrotoxicosis, 31 age-matched pregnant patients with Graves' disease and 24 age- and sex-matched non-pregnant patients with Graves' disease) and 25 age- and sex-matched healthy euthyroid subjects were assessed with color-flow Doppler ultrasonography. RESULTS: The right and left inferior thyroid artery-peak systolic and end-diastolic velocities in patients with gestational transient thyrotoxicosis were found to be significantly lower than those of pregnant patients with Graves' disease and higher than those of healthy euthyroid subjects. However, the right and left inferior thyroid artery peak systolic and end-diastolic velocities in pregnant patients with Graves' disease were significantly lower than those of non-pregnant patients with Graves' disease. The right and left inferior thyroid artery peak systolic and end-diastolic velocities were positively correlated with TSH-receptor antibody levels. We found an overlap between the inferior thyroid artery-blood flow velocities in a considerable number of patients with gestational transient thyrotoxicosis and pregnant patients with Graves' disease. CONCLUSIONS: This study suggests that the measurement of inferior thyroid artery-blood flow velocities with color-flow Doppler ultrasonography does not have sufficient sensitivity and specificity to be recommended as an initial diagnostic test for a differential diagnosis between gestational transient thyrotoxicosis and Graves' disease during pregnancy. PMID:22358236

  14. B-mode Ultrasound Versus Color Doppler Twinkling Artifact in Detecting Kidney Stones

    PubMed Central

    Harper, Jonathan D.; Hsi, Ryan S.; Shah, Anup R.; Dighe, Manjiri K.; Carter, Stephen J.; Moshiri, Mariam; Paun, Marla; Lu, Wei; Bailey, Michael R.

    2013-01-01

    Abstract Purpose To compare color Doppler twinkling artifact and B-mode ultrasonography in detecting kidney stones. Patients and Methods Nine patients with recent CT scans prospectively underwent B-mode and twinkling artifact color Doppler ultrasonography on a commercial ultrasound machine. Video segments of the upper pole, interpolar area, and lower pole were created, randomized, and independently reviewed by three radiologists. Receiver operator characteristics were determined. Results There were 32 stones in 18 kidneys with a mean stone size of 8.9±7.5 mm. B-mode ultrasonography had 71% sensitivity, 48% specificity, 52% positive predictive value, and 68% negative predictive value, while twinkling artifact Doppler ultrasonography had 56% sensitivity, 74% specificity, 62% positive predictive value, and 68% negative predictive value. Conclusions When used alone, B-mode is more sensitive, but twinkling artifact is more specific in detecting kidney stones. This information may help users employ twinkling and B-mode to identify stones and developers to improve signal processing to harness the fundamental acoustic differences to ultimately improve stone detection. PMID:23067207

  15. [Vascular complications following kidney transplant: the role of color-Doppler imaging].

    PubMed

    Granata, Antonio; Floccari, Fulvio; Lentini, Paolo; Vittoria, Salvatore; Di Pietro, Fabio; Zamboli, Pasquale; Fiorini, Fulvio; Fatuzzo, Pasquale

    2012-01-01

    The progressive decline in the incidence of graft rejection has made urological, surgical, parenchymal and vascular complications of kidney transplant more frequent. The latter, although accounting for only 5-10% of all post-transplant complications, are a frequent cause of graft loss. Ultrasonography, both in B-mode and with Doppler ultrasound, is an important diagnostic tool in case of clinical conditions which might impair kidney function. Even though ultrasonography is considered fundamental in the diagnosis of parenchymal and surgical complications of the transplanted kidney, its role is not fully understood in case of vascular complications of the graft. The specificity of Doppler ultrasound is very important in case of stenosis of the transplanted renal artery, pseudoaneurysms, arteriovenous fistulas, and thrombosis with complete or partial artery or vein occlusion. Doppler and color determinations present high diagnostic accuracy, which is higher in case of successive measurements performed during the follow-up of the graft. Modern techniques including contrast-enhanced ultrasound increase the diagnostic power of ultrasonography in case of vascular complications of the transplanted kidney, planted kidney.

  16. Validation of color Doppler ultrasonography for evaluating the uterine blood flow and perfusion during late normal pregnancy and uterine torsion in buffaloes.

    PubMed

    Hussein, Hassan A

    2013-04-15

    The aim of this study was to verify the efficacy of color Doppler ultrasonography for diagnosis of degree and duration of uterine torsion in buffaloes. In Assiut province/Upper Egypt, 65 buffaloes (37 with uterine torsion, 28 with normal late pregnancy) were examined clinically and using Doppler ultrasonography. The Doppler indices including resistance index (RI), pulsatility index (PI), time-averaged maximum velocity (TAMV), and blood flow volume (BFV) in the arteries ipsilateral to the uterine torsion (IPUT) and in arteries contralateral to the uterine torsion (COUT) were recorded. Methods of correction were documented along with dam and calf survival. Torsion was recorded postcervically with vaginal involvement in 35/37 (94.6%) of the cases. The degrees of uterine torsion were light and high in 9/37 (24.3%) and 28/37 (75.7%) of the cases, respectively (P = 0.001). Right uterine torsion was present in 36/37 (97.3%) of the cases (P = 0.0001). Pulsatility index, RI, TAMV, and BFV in IPUT and COUT did not differ significantly (P > 0.05) in normal late pregnancy. The PI and RI in IPUT were significantly higher (P < 0.01) than in COUT, and the TAMV and BFV in IPUT were less (P < 0.001) than that in COUT in uterine torsion. The PI and RI of torsion cases in IPUT were higher (P < 0.001) than that in normal pregnancy. Time-averaged maximum velocity and BFV in torsion cases were lower (P < 0.01) than that of normal pregnancy in IPUT. There was approximately 50% of RI and PI higher than in light degree uterine torsion in IPUT (P < 0.001). Consequently, TAMV and BFV were greatly lower (P < 0.0001) than that in light degree in IPUT. Pulsatility index and RI were positively correlated (r = 0.856; P < 0.001) with the duration and degree of the uterine torsion, and TAMV and BFV were negatively correlated (r = -0.763; P < 0.001). In all cases of uterine torsion the uterine flow velocity waveform showed high systolic flow and absence of early diastolic flow and poor uterine and

  17. B-Flow Imaging in Lower Limb Peripheral Arterial Disease and Bypass Graft Ultrasonography.

    PubMed

    D'Abate, Fabrizio; Ramachandran, Veni; Young, Mark A; Farrah, John; Ahmed, Mudasar H; Jones, Keith; Hinchliffe, Robert J

    2016-09-01

    Doppler ultrasonography plays a key role in the diagnosis of peripheral arterial disease, but is often limited by pitfalls that may be overcome by B-flow imaging. Thus far, there is little information on B-flow imaging for the assessment of peripheral arterial disease and bypass grafts in lower limbs. This article describes the authors' early experience with B-flow in the lower extremities. Sixty patients were included among a large cohort of patients routinely referred to the vascular laboratory for peripheral arterial disease and bypass graft assessments. Two experienced vascular sonographers performed all scans, comparing color Doppler ultrasonography with B-flow imaging. All scans were performed using a combination of the 9 L linear and C2-9 curvilinear transducers with the LOGIQ E9 system (GE Healthcare, Waukesha, WI, USA). Our experience indicates that this relatively unexplored technology has the potential to significantly improve peripheral blood flow evaluation. Nevertheless, B-flow imaging is not exempt from limitations and should be considered complementary to color Doppler ultrasonography. Copyright © 2016 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  18. Preoperative color Doppler assessment in planning of gluteal perforator flaps.

    PubMed

    Isken, Tonguc; Alagoz, M Sahin; Onyedi, Murat; Izmirli, Hakki; Isil, Eda; Yurtseven, Nagehan

    2009-02-01

    Gluteal artery perforator flaps have gained popularity due to reliability, preservation of the muscle, versatility in flap design without restricting other flap options, and low donor-site morbidity in ambulatory patients and possibility of enabling future reconstruction in paraplegic patients. But the inconstant anatomy of the vascular plexus around the gluteal muscle makes it hard to predict how many perforators are present, what their volume of blood flow and size are, where they exit the overlying fascia, and what their course through the muscle will be. Without any prior investigations, the reconstructive surgeon could be surprised intraoperatively by previous surgical damage, scar formation, or anatomic variants.For these reasons, to confirm the presence and the location of gluteal perforators preoperatively we have used color Doppler ultrasonography. With the help of the color Doppler ultrasonography 26 patients, 21 men and 5 women, were operated between the years 2002 and 2007. The mean age of patients was 47.7 (age range: 7-77 years). All perforator vessels were marked preoperatively around the defect locations. The perforator based flap that will allow primary closure of the donor site and the defect without tension was planned choosing the perforator that showed the largest flow in color Doppler ultrasonography proximally. Perforators were found in the sites identified with color Doppler ultrasonography in all other flaps. In our study, 94.4% flap viability was ensured in 36 perforator-based gluteal area flaps. Mean flap elevation time was 31.9 minutes. We found that locating the perforators preoperatively helps to shorten the operation time without compromising a reliable viability of the perforator flaps, thus enabling the surgeon easier treatment of pressure sores.

  19. Transcranial Doppler Ultrasonography Identifies Symptomatic Cavum Septum Pellucidum Cyst: Case Report

    PubMed Central

    Bell, Randy S.; Vo, Alexander H.; Dirks, Michael S.; Mossop, Corey; Gilhooly, John E.; Cooper, Patrick B.; Razumovsky, Alexander Y.; Armonda, Rocco A.

    2010-01-01

    Objective: Cavum Septum Pellucidum (CSP) cysts are considered normal anatomic variants, comprising as many as 15% of the adult and 85% of pediatric populations. On rare occasions, the cavum can obstruct CSF outflow from the lateral ventricles causing elevated intracranial pressure (ICP) and headaches. The purpose of this paper is to present a challenging case of new onset symptomatic CSP in a previously healthy adult male without papilledema and elevated ICP detected by transcranial Doppler (TCD) ultrasonography. Clinical Presentation: A previously healthy 44 year-old man presented to the neurology service with debilitating positional headaches that were mitigated solely by recumbent positioning. A magnetic resonance imaging scan (MRI) of the brain revealed a cavum septum pellucidum. A lumbar puncture was performed and revealed normal ICP. No papilledema was evident on fundoscopic examination. A CSF flow study revealed normal dye opacification pattern without evidence of CSF leak. Intervention: Without other clinical indicators of high ICP, but a history suspicious for symptomatic CSP, TCD study was performed and revealed abnormally low cerebral blood flow velocities (CBFV’s) and significantly elevated pulsatility indices (PI’s) for patient’s age indicative of high ICP. Endoscopic fenestration of the septum pellucidum was performed improving the patient’s headaches and normalization of the PI’s and CBFV’s to normal (p<0.01). Conclusions: Symptomatic CSP is a difficult diagnosis to make based on existing diagnostic paradigm. TCD in the absence of other objective confirmatory studies, can aid in the diagnosis and provide information about the success of fenestration of the cavum septum. PMID:22518255

  20. Colour Doppler analysis of ophthalmic vessels in the diagnosis of carotic artery and retinal vein occlusion, diabetic retinopathy and glaucoma: systematic review of test accuracy studies.

    PubMed

    Bittner, Mario; Faes, Livia; Boehni, Sophie C; Bachmann, Lucas M; Schlingemann, Reinier O; Schmid, Martin K

    2016-12-07

    Colour Doppler analysis of ophthalmic vessels has been proposed as a promising tool in the diagnosis of various eye diseases, but the available diagnostic evidence has not yet been assessed systematically. We performed a comprehensive systematic review of the literature on the diagnostic properties of Colour Doppler imaging (CDI) assessing ophthalmic vessels and provide an inventory of the available evidence. Eligible papers were searched electronically in (Pre) Medline, Embase and Scopus, and via cross-checking of reference lists. The minimum requirement to be included was the availability of original data and the possibility to construct a two-by-two table. Study selection, critical appraisal using the QUADAS II instrument and extraction of salient study characteristics was made in duplicate. Sensitivity and specificity was computed for each study. We included 11 studies (15 two-by-two tables) of moderate methodological quality enrolling 820 participants (range 30 to 118). In 44.4% participants were female (range 37-59% in specific subgroups). CDI was assessed for internal carotid stenosis, diabetic retinopathy, glaucoma, and branch or central retinal vein occlusion diagnosis. There was insufficient data to pool the results for specific illnesses. For the assessments of ophthalmic arteries, mean sensitivity was 0.69 (range 0.27-0.96) with a corresponding mean specificity of 0.83 (range 0.70-0.96). Mean sensitivity of the central retinal artery assessments was 0.58 (range 0.31-0.84) and the corresponding mean specificity was 0.82 (range 0.63-0.94). Robust assessments of the diagnostic value of colour Doppler analysis remain uncommon, limiting the possibilities to extrapolate its true potential for clinical practice. PROSPERO 2014:CRD42014014027.

  1. Detection of severe digital vasculopathy in systemic sclerosis by colour Doppler sonography is associated with digital ulcers.

    PubMed

    Lüders, Susanne; Friedrich, Stefanie; Ohrndorf, Sarah; Glimm, Anne-Marie; Burmester, Gerd-Rüdiger; Riemekasten, Gabriela; Backhaus, Marina

    2017-11-01

    Colour Doppler ultrasonography (CDUS) is very important in general vascular diagnostic procedures. Its role in determining the extent of vasculopathy in Systemic Sclerosis (SSc) needs further investigation. The aim of this study was to compare the presence of altered arteries with nailfold capillaroscopy and clinical signs of ischaemia, that is, digital ulcers or pitting scars (DU/PS). A feasible CDUS protocol is provided. Two thousand five hundred and twenty-eight arteries of the fingers, palms and wrists from 79 SSc patients (32 arteries per patient) were examined using CDUS. Furthermore, nailfold capillaroscopy, clinical and laboratory data were evaluated. Narrowed or occluded lumens were seen in 39.8% of all assessable arteries (n = 2489) and 48.9% of all proper palmar digital arteries (n = 1564) but only 15.6% (P < 0.0001) of proximal arteries (n = 924). Fingerwise analyses presented significant coincidence of pathological CDUS findings and DU/PS (P = 0.0009). Pathological CDUS findings were also associated with elevated CRP concentrations, current or past smoking with ⩾20 pack-years, male gender and present or past DU/PS. Receiver operating characteristic curve analysis (area under the curve = 0.727) suggested a cut-off value of ⩾20% pathological vessels (sensitivity: 90.7%; specificity: 47.8%) for the presence of DU/PS. An examination protocol focusing on the right-hand digits II-V (proper palmar digital arteries) revealed similar results (area under the curve = 0.751; sensitivity: 93.0%; specificity: 43.5%). CDUS of hand and finger arteries allows measurement of the extent of SSc vasculopathy, which is associated with clinical signs of chronic malperfusion. A shortened examination protocol of CDUS (right-hand digits II-V; 15 min instead of 45 min examination time) could complement vascular diagnostics in SSc. © The Author 2017. Published by Oxford University Press on behalf of the British Society for Rheumatology. All rights reserved. For Permissions

  2. Correlation between computerised findings and Newman's scaling on vascularity using power Doppler ultrasonography imaging and its predictive value in patients with plantar fasciitis

    PubMed Central

    Chen, H; Ho, H M; Ying, M; Fu, S N

    2012-01-01

    Objectives The purpose of this study was to correlate findings on small vessel vascularity between computerised findings and Newman's scaling using power Doppler ultrasonography (PDU) imaging and its predictive value in patients with plantar fasciitis. Methods PDU was performed on 44 patients (age range 30–66 years; mean age 48 years) with plantar fasciitis and 46 healthy subjects (age range 18–61 years; mean age 36 years). The vascularity was quantified using ultrasound images by a customised software program and graded by Newman's grading scale. Vascular index (VI) was calculated from the software program as the ratio of the number of colour pixels to the total number of pixels within a standardised selected area of proximal plantar fascia. The 46 healthy subjects were examined on 2 occasions 7–10 days apart, and 18 of them were assessed by 2 examiners. Statistical analyses were performed using intraclass correlation coefficient and linear regression analysis. Results Good correlation was found between the averaged VI ratios and Newman's qualitative scale (ρ = 0.70; p<0.001). Intratester and intertester reliability were 0.89 and 0.61, respectively. Furthermore, higher VI was correlated with less reduction in pain after physiotherapeutic intervention. Conclusions The computerised VI not only has a high level of concordance with the Newman grading scale but is also reliable in reflecting the vascularity of proximal plantar fascia, and can predict pain reduction after intervention. This index can be used to characterise the changes in vascularity of patients with plantar fasciitis, and it may also be helpful for evaluating treatment and monitoring the progress after intervention in future studies. PMID:22167513

  3. Association of vitamin D insufficiency/deficiency with thyroid artery Doppler ultrasonography in patients with Hashimoto thyroiditis.

    PubMed

    Nalbant, Ahmet; Aydin, Ayhan; Karacan, Alper; Onmez, Attila; Tamer, Ali; Cinemre, Hakan

    2017-01-01

    During the course of the autoimmune thyroid diseases, ultrasonography change parallel to histopathology. Vitamin D is associated with autoimmune diseases and thus can affect thyroid blood flow. Our aim was to investigate the relationship between vitamin D insufficiency/deficiency and thyroid hemodynamic indices in patients with Hashimoto thyroiditis. A total of 93 patients who presented to Sakarya University Endocrinology outpatient clinic from April to September 2016 and diagnosed with Hashimoto thyroiditis were included in this study. Clinical and serologic data, thyroid antibodies and 25(OH)D3 were evaluated. Mean peak systolic velocity(mPSV), mean end-diastolic velocity (EDV), mean resistive index (RI) flows of superior and inferior thyroid arteries were measured with B-mode Doppler ultrasonography. Vitamin D insufficiency/deficiency was detected in 59 (63.4%). TPO Ab and TgAb levels were found higher in patients with vitamin D insufficiency/deficiency. In the normal vitamin D group, superior thyroid artery mPSV (32.21±6.73cm/s) and EDV(13.27±2.80 cm/s) were higher than in the low vitamin D group [mPSV (28.32±8.99cm/s) and EDV(10.67±3.68 cm/s)] (P=0.034, P=0.001, respectively). Inferior thyroid artery EDV value was higher in the normal compared to the low vitamin D group (0.032). RI measured in all arteries were higher in the vitamin D insufficient/deficient group compared to the Vitamin D normal group (p=0.001). Vitamin-D insufficiency/deficiency has led to reduced parenchymal blood supply and increased micro-vascular resistance in Hashimoto thyroiditis patients.

  4. Colour flow and motion imaging.

    PubMed

    Evans, D H

    2010-01-01

    Colour flow imaging (CFI) is an ultrasound imaging technique whereby colour-coded maps of tissue velocity are superimposed on grey-scale pulse-echo images of tissue anatomy. The most widespread use of the method is to image the movement of blood through arteries and veins, but it may also be used to image the motion of solid tissue. The production of velocity information is technically more demanding than the production of the anatomical information, partly because the target of interest is often blood, which backscatters significantly less power than solid tissues, and partly because several transmit-receive cycles are necessary for each velocity estimate. This review first describes the various components of basic CFI systems necessary to generate the velocity information and to combine it with anatomical information. It then describes a number of variations on the basic autocorrelation technique, including cross-correlation-based techniques, power Doppler, Doppler tissue imaging, and three-dimensional (3D) Doppler imaging. Finally, a number of limitations of current techniques and some potential solutions are reviewed.

  5. [The diagnostic value of ultrasonic elastography and ultrasonography comprehensive score in cervical lesions].

    PubMed

    Lu, R; Xiao, Y

    2017-07-18

    Objective: To evaluate the clinical value of ultrasonic elastography and ultrasonography comprehensive scoring method in the diagnosis of cervical lesions. Methods: A total of 116 patients were selected from the Department of Gynecology of the first hospital affiliated with Central South University from March 2014 to September 2015.All of the lesions were preoperatively examined by Doppler Ultrasound and elastography.The elasticity score was determined by a 5-point scoring method. Calculation of the strain ratio was based on a comparison of the average strain measured in the lesion with the adjacent tissue of the same depth, size, and shape.All these ultrasonic parameters were quantified, added, and arrived at ultrasonography comprehensive scores.To use surgical pathology as the gold standard, the sensitivity, specificity, accuracy of Doppler Ultrasound, elasticity score and strain ratio methods and ultrasonography comprehensive scoring method were comparatively analyzed. Results: (1) The sensitivity, specificity, and accuracy of Doppler Ultrasound in diagnosing cervical lesions were 82.89% (63/76), 85.0% (34/40), and 83.62% (97/116), respectively.(2) The sensitivity, specificity, and accuracy of the elasticity score method were 77.63% (59/76), 82.5% (33/40), and 79.31% (92/116), respectively; the sensitivity, specificity, and accuracy of the strain ratio measure method were 84.21% (64/76), 87.5% (35/40), and 85.34% (99/116), respectively.(3) The sensitivity, specificity, and accuracy of ultrasonography comprehensive scoring method were 90.79% (69/76), 92.5% (37/40), and 91.38% (106/116), respectively. Conclusion: (1) It was obvious that ultrasonic elastography had certain diagnostic value in cervical lesions. Strain ratio measurement can be more objective than elasticity score method.(2) The combined application of ultrasonography comprehensive scoring method, ultrasonic elastography and conventional sonography was more accurate than single parameter.

  6. Role of color Doppler in differentiation of Graves' disease and thyroiditis in thyrotoxicosis

    PubMed Central

    Donkol, Ragab Hani; Nada, Aml Mohamed; Boughattas, Sami

    2013-01-01

    AIM: To evaluate the role of thyroid blood flow assessment by color-flow Doppler ultrasonography in the differential diagnosis of thyrotoxicosis and compare it to technetium pertechnetate thyroid scanning. METHODS: Twenty-six patients with thyrotoxicosis were included in the study. Clinical history was taken and physical examination and thyroid function tests were performed for all patients. Thyroid autoantibodies were measured. The thyroid glands of all patients were evaluated by gray scale ultrasonography for size, shape and echotexture. Color-flow Doppler ultrasonography of the thyroid tissue was performed and spectral flow analysis of both inferior thyroid arteries was assessed. Technetium99 pertechnetate scanning of the thyroid gland was done for all patients. According to thyroid scintigraphy, the patients were divided into two groups: 18 cases with Graves’ disease and 8 cases with Hashimoto’s thyroiditis. All patients had suppressed thyrotropin. The diagnosis of Graves’ disease and Hashimoto’s thyroiditis was supported by the clinical picture and follow up of patients. RESULTS: Peak systolic velocities of the inferior thyroid arteries were significantly higher in patients with Graves’ disease than in patients with thyroiditis (P = 0.004 in the right inferior thyroid artery and P = 0.001 in left inferior thyroid artery). Color-flow Doppler ultrasonography parameters demonstrated a sensitivity of 88.9% and a specificity of 87.5% in the differential diagnosis of thyrotoxicosis. CONCLUSION: Color Doppler flow of the inferior thyroid artery can be used in the differential diagnosis of thyrotoxicosis, especially when there is a contraindication of thyroid scintigraphy by radioactive material in some patients. PMID:23671754

  7. Effect of a single injection of gonadotropin-releasing hormone (GnRH) and human chorionic gonadotropin (hCG) on testicular blood flow measured by color doppler ultrasonography in male Shiba goats

    PubMed Central

    SAMIR, Haney; SASAKI, Kazuaki; AHMED, Eman; KAREN, Aly; NAGAOKA, Kentaro; EL SAYED, Mohamed; TAYA, Kazuyoshi; WATANABE, Gen

    2015-01-01

    Although color Doppler ultrasonography has been used to evaluate testicular blood flow in many species, very little has been done in goat. Eight male Shiba goats were exposed to a single intramuscular injection of either gonadotropin-releasing hormone (GnRH group; 1 µg/kg BW) or human chorionic gonadotropin (hCG group; 25 IU/kg BW). Plasma testosterone (T), estradiol (E2) and inhibin (INH) were measured just before (0 hr) and at different intervals post injection by radioimmunoassay. Testis volume (TV) and Doppler indices, such as resistive index (RI) and pulsatility index (PI) of the supratesticular artery, were measured by B-mode and color Doppler ultrasonography, respectively. The results indicated an increase in testicular blood flow in both groups, as RI and PI decreased significantly (P<0.05), but this increase was significant higher and earlier in hCG group (1 hr) than in the GnRH group (2 hr). A high correlation was found for RI and PI with both T (RI, r= −0.862; PI, r= −0.707) and INH in the GnRH group (RI, r=0.661; PI, r=0.701). However, a significant (P<0.05) correlation was found between E2 and both RI (r= −0.610) and PI (r= −0.763) in hCG group. In addition, TV significantly increased and was highly correlated with RI in both groups (GnRH, r= −0.718; hCG, r= −0.779). In conclusion, hCG and GnRH may improve testicular blood flow and TV in Shiba goats. PMID:25715956

  8. [The Value of High Frequency Color Doppler Ultrasonography in the Diagnosis of Solid Skin Tumorsa-a Preliminary Study].

    PubMed

    Zhong, Lin; Tang, Yuan-Jiao; Yang, Yu-Jia; Qiu, Li

    2017-01-01

    To explore the value of high frequency color doppler ultrasonography in differentiating benign and malignant skin solid tumors. Clinical and ultrasonic data of cutaneous solid tumors confirmed by pathology in our hospital were collected. The differences in clinical and sonographic features between benign and malignant tumors were statistically analyzed. A total of 512 patients, involving 527 cases of skin solid tumors, were enrolled in this study. The ultrasonic detected 99.43% of the cases, with 99.02% accuracy in locating the lesions. The benign and malignant tumors showed differences in patient age, location, multiple occurance, location and depth, surface skin condition, tumor size, echo, morphology, uniformity, calcification, blood flow status, tumor rear area and peripheral echo, and pathological requests ( P <0.05). High frequency ultrasound has excellent detection rate of skin tumors, which can locate invasion depth of skin accurately. Benign and malignant skin tumors show differences in a number of clinical and ultrasound features.

  9. The prediction of radiofrequency ablation zone volume using vascular indices of 3-dimensional volumetric colour Doppler ultrasound in an in vitro blood-perfused bovine liver model

    PubMed Central

    Lanctot, Anthony C; McCarter, Martin D; Roberts, Katherine M; Glueck, Deborah H; Dodd, Gerald D

    2017-01-01

    Objective: To determine the most reliable predictor of radiofrequency (RF) ablation zone volume among three-dimensional (3D) volumetric colour Doppler vascular indices in an in vitro blood-perfused bovine liver model. Methods: 3D colour Doppler volume data of the local hepatic parenchyma were acquired from 37 areas of 13 bovine livers connected to an in vitro oxygenated blood perfusion system. Doppler vascular indices of vascularization index (VI), flow index (FI) and vascularization flow index (VFI) were obtained from the volume data using 3D volume analysis software. 37 RF ablations were performed at the same locations where the ultrasound data were obtained from. The relationship of these vascular indices and the ablation zone volumes measured from gross specimens were analyzed using a general linear mixed model fit with random effect for liver and backward stepwise regression analysis. Results: FI was significantly associated with ablation zone volumes measured on gross specimens (p = 0.0047), but explained little of the variance (Rβ2 = 0.21). Ablation zone volume decreased by 0.23 cm3 (95% confidence interval: −0.38, −0.08) for every 1 increase in FI. Neither VI nor VFI was significantly associated with ablation zone volumes (p > 0.05). Conclusion: Although FI was associated with ablation zone volumes, it could not sufficiently explain their variability, limiting its clinical applicability. VI, FI and VFI are not clinically useful in the prediction of RF ablation zone volume in the liver. Advances in knowledge: Despite a significant association of FI with ablation zone volumes, VI, FI and VFI cannot be used for their prediction. Different Doppler vascular indices need to be investigated for clinical use. PMID:27925468

  10. Soft-tissue tumor differentiation using 3D power Doppler ultrasonography with echo-contrast medium injection.

    PubMed

    Chiou, Hong-Jen; Chou, Yi-Hong; Chen, Wei-Ming; Chen, Winby; Wang, Hsin-Kai; Chang, Cheng-Yen

    2010-12-01

    We aimed to evaluate the ability of 3-dimensional power Doppler ultrasonography to differentiate soft-tissue masses from blood flow and vascularization with contrast medium. Twenty-five patients (mean age, 44.1 years; range, 12-77 years) with a palpable mass were enrolled in this study. Volume data were acquired using linear and convex 3-dimensional probes and contrast medium injected manually by bolus. Data were stored and traced slice by slice for 12 slices. All patients were scanned by the same senior sonologist. The vascular index (VI), flow index (FI), and vascular-flow index (VFI) were automatically calculated after the tumor was completely traced. All tumors were later confirmed by pathology. The study included 8 benign (mean, 36.5 mL; range, 2.4-124 mL) and 17 malignant (mean, 319.4 mL; range, 9.9-1,179.6 mL) tumors. Before contrast medium injection, mean VI, FI and VFI were, respectively, 3.22, 32.26 and 1.07 in benign tumors, and 1.97, 29.33 and 0.67 in malignant tumors. After contrast medium injection, they were, respectively, 20.85, 37.33 and 8.52 in benign tumors, and 40.12, 41.21 and 17.77 in malignant tumors. The mean differences between with and without contrast injection for VI, FI and VFI were, respectively, 17.63, 5.07 and 7.45 in benign tumors, and 38.15, 11.88 and 16.55 in malignant tumors. Tumor volume, VI, FI and VFI were not significantly different between benign and malignant tumors before and after echo-contrast medium injection. However, VI, FI and VFI under self-differentiation (differences between with and without contrast injection) were significantly different between malignant and benign tumors. Three-dimensional power Doppler ultrasound is a valuable tool for differential diagnosis of soft-tissue tumors, especially with the injection of an echo-contrast medium. Copyright © 2010 Elsevier. Published by Elsevier B.V. All rights reserved.

  11. Angiosonography in suspicious breast lesions with non-diagnostic FNAC: comparison with power Doppler US.

    PubMed

    Caumo, F; Carbognin, G; Casarin, A; Pinali, L; Vasori, S; D'Onofrio, M; Pozzi Mucelli, R

    2006-02-01

    The purpose of this study was to evaluate the accuracy of angiosonography in comparison with colour Doppler ultrasound (US) in the discrimination of suspicious breast lesions with nondiagnostic fine-needle aspiration cytology (FNAC). Pre-operative Power Doppler US and angiosonography were prospectively performed in 20 suspicious breast lesions with non-diagnostic FNAC. A second-generation US contrast agent was utilised with a high-frequency transducer and a contrast-specific algorithm (low acoustic pressure CnTI). The enhancement characteristics of all lesions were analysed using qualitative and quantitative parameters obtained from time-intensity curves with the different imaging modalities. The final diagnosis was confirmed at pathology in all cases. Microvessel density (MVD) was assessed in the surgical specimen using CD34. The correct assessment of biological behaviour was achieved in all cases by angiosonography (sensitivity of 100%; specificity of 91%) and colour Doppler US (45% sensitivity; 78% specificity). MVD correlated with the biological behaviour. Angiosonography is more accurate than colour Doppler US in the correct assessment of biological behaviour of suspicious breast lesions.

  12. Evaluation of transplant renal artery blood flow by Doppler sound-spectrum analysis.

    PubMed

    Reinitz, E R; Goldman, M H; Sais, J; Rittgers, S E; Lee, H M; Mendez-Picon, G; Muakkassa, W F; Barnes, R W

    1983-04-01

    Doppler ultrasonography sound-spectrum analysis (SSA) was used to evaluate blood flow in the transplanted kidney and its renal artery. Seven patients with posttransplant hypertension and a bruit over the transplanted kidney were screened for renal artery stenosis (RAS). In five patients, RAS was diagnosed by SSA, and in two it was not. These findings were confirmed by subsequent angiography in all patients. Three patients studied after surgical correction of their RAS had improvement in their SSA patterns. Fourteen hypertensive patients with a cause other than RAS were evaluated by SSA. None of them had SSA findings suggestive of RAS. Doppler ultrasonography with SSA is an effective, noninvasive technique of monitoring transplant renal blood flow, especially in the screening of hypertensive transplant recipients for transplant RAS.

  13. Sensitivity and specificity of ultrasonography and low-field magnetic resonance imaging for diagnosing arthritis.

    PubMed

    Broll, Matthias; Albrecht, Katinka; Tarner, Ingo; Müller-Ladner, Ulf; Strunk, Johannes

    2012-01-01

    To evaluate the value of grey-scale ultrasonography (US) including power Doppler ultrasonography (PDUS) and low-field magnetic resonance imaging (MRI) for the diagnosis of arthritis in a diagnostic phase III study. Fifty consecutive patients with suspected arthritis were included in the study. Following a standardised protocol, US of the carpus and the metacarpophalangeal (MCP) joints of the dominant hand was performed. Subsequently, low-field MRI was done using standard sequences, with contrast agent (Gadolinium DTPA) administered to 29 patients. In 32 out of 50 patients a clinical diagnosis of arthritis was established. In grey-scale ultrasonography including PDUS, sensitivity and specificity were determined as 0.94 and 0.5, respectively, for synovitis (effusion and hypertrophy), 0.72 and 0.94, respectively, for Doppler signals, and 0.38 and 1.0, respectively, for bone erosions. In low-field MRI, sensitivity and specificity values were 0.77 and 0.75, respectively, for synovitis (when using contrast agent), 0.48 and 0.78, respectively, for bone marrow oedema, and 0.58 and 0.83, respectively, for bone erosion. Both grey-scale ultrasonography including PDUS and low-field MRI are suitable imaging methods for diagnosing arthritis at an early stage. However, PDUS displays a higher specificity and almost the same sensitivity as compared to contrast-enhanced MRI, while being a much simpler and less costly procedure.

  14. Comparative Evaluation of Advanced and Conventional Diagnostic Aids for Endodontic Management of Periapical Lesions, An in Vivo Study

    PubMed Central

    Singh, Smita; Arora, Saurabh; Sandhu, Amneet Kaur; Dhingra, Ravneet

    2015-01-01

    Aim: To evaluate efficacy of Colour Doppler ultrasonography (CDUSG), direct digital radiography (DDR) and conventional radiography (CR) in diagnosis of periapical lesions and to clinically correlate treatment plan of periapical diseases. Materials and Methods: Thirty patients which were diagnosed with periapical lesions in anterior region by using both conventional and digital radiography were examined using colour doppler ultrasound imaging at the site of lesion. The images of each lesion were analysed by two endodontists and by an expert oral radiologist. A tentative differential diagnosis was agreed upon, based on certain principles discussed in article, then a diagnosis between cyst, granuloma and mixed lesions was made. Periapical lesions diagnosed as mixed lesions by colour doppler ultrasonography (CDUSG) were treated non-surgically whereas other periapical lesions were treated surgically. Tissues obtained during endodontic surgery were processed and examined for histopathological findings, and compared with the diagnosis made by ultrasound images. Statistical analysis was done with Chi-Square test and using one-way-Anova. Results: The periapical lesions which were diagnosed as granuloma by ultrasonographic findings, was confirmed by the results of histopathological examination in all 16 surgically treated cases. The lesions in rest of the 14 cases which showed vascularity and were diagnosed as mixed lesions by ultrasonography, were treated non-surgically and had a favourable prognosis. Conclusion: CR and DDR facilitate diagnosis of the presence of periapical disease, but do not provide and information of its nature. CDUSG imaging facilitates accurate information on the pathological nature of the lesion and hence can lead to predictable treatment planning. PMID:25738075

  15. Real-time and interactive virtual Doppler ultrasound

    NASA Astrophysics Data System (ADS)

    Hirji, Samira; Downey, Donal B.; Holdsworth, David W.; Steinman, David A.

    2005-04-01

    This paper describes our "virtual" Doppler ultrasound (DUS) system, in which colour DUS (CDUS) images and DUS spectrograms are generated on-the-fly and displayed in real-time in response to position and orientation cues provided by a magnetically tracked handheld probe. As the presence of complex flow often confounds the interpretation of Doppler ultrasound data, this system will serve to be a fundamental tool for training sonographers and gaining insight into the relationship between ambiguous DUS images and complex blood flow dynamics. Recently, we demonstrated that DUS spectra could be realistically simulated in real-time, by coupling a semi-empirical model of the DUS physics to a 3-D computational fluid dynamics (CFD) model of a clinically relevant flow field. Our system is an evolution of this approach where a motion-tracking device is used to continuously update the origin and orientation of a slice passing through a CFD model of a stenosed carotid bifurcation. After calibrating our CFD model onto a physical representation of a human neck, virtual CDUS images from an instantaneous slice are then displayed at a rate of approximately 15 Hz by simulating, on-the-fly, an array of DUS spectra and colour coding the resulting spectral mean velocity using a traditional Doppler colour scale. Mimicking a clinical examination, the operator can freeze the CDUS image on-screen, and a spectrogram corresponding to the selected sample volume location is rendered at a higher frame rate of at least 30 Hz. All this is achieved using an inexpensive desktop workstation and commodity graphics card.

  16. [Parenchymal complications of the transplanted kidney: the role of color-Doppler imaging].

    PubMed

    Granata, Antonio; Clementi, Silvia; Clementi, Anna; Di Pietro, Fabio; Scarfia, Viviana R; Insalaco, Monica; Aucella, Filippo; Prencipe, Michele; Fiorini, Fulvio; Sicurezza, Elvia

    2012-01-01

    Kidney transplantation is the treatment of choice for end-stage renal disease, given the better quality of life of transplanted patients when compared to patients on maintenance dialysis. In spite of surgical improvements and new immunosuppressive regimens, part of the transplanted grafts still develop chronic dysfunction. Ultrasonography, both in B-mode and with Doppler ultrasound, is an important diagnostic tool in case of clinical conditions which might impair kidney function. Even though ultrasonography is considered fundamental in the diagnosis of vascular and surgical complications of the transplanted kidney, its role is not fully understood in case of parenchymal complications of the graft. The specificity of Doppler ultrasound is low both in case of acute complications such as acute tubular necrosis, drug toxicity and acute rejection, and in case of chronic conditions such as chronic allograft nephropathy. Single determinations of resistance indices present low diagnostic accuracy, which is higher in case of successive measurements performed during the follow-up of the graft. Modern techniques including tissue pulsatility index, maximal fractional area and contrast-enhanced ultrasound increase the diagnostic power of ultrasonography in case of parenchymal complications of the transplanted kidney.

  17. Portable duplex ultrasonography: A diagnostic and decision-making tool in reconstructive microsurgery.

    PubMed

    Gravvanis, Andreas; Karakitsos, Dimitrios; Dimitriou, Vasilios; Zogogiannis, Ioannis; Katsikeris, Nick; Karabinis, Andreas; Tsoutsos, Dimosthenis

    2010-07-01

    Unidirectional Doppler is a common diagnostic tool by the Reconstructive Microsurgeons; however, it may generate false signals and surely provides less imaging data as compared to duplex ultrasonography. We have reviewed the use of Portable Duplex Ultrasonography (PDU) in 16 patients who underwent complex soft-tissue/bone reconstruction, aiming to determine its role in the design and management of free tissue transfer. According to our data, there were modifications either of the surgical plan and/or of patient's management, based on PDU findings, in 10 out of 16 patients (62.5%). The use of ultrasound directed to subtle modifications in three patients (19%), but to significant changes of the surgical plan in four patients (25%). Also, the use of ultrasound improved significantly the postoperative management in three patients (19%). Thus, significant impact of PDU in patient's treatment was recorded in 44% of cases. Portable ultrasound represents generally available method for preoperative, intraoperative, and postoperative diagnosis and decision-making in free tissue transfer, hence could replace in the near future the unidirectional Doppler in the hands of Microsurgeons. (c) 2010 Wiley-Liss, Inc.

  18. Using functional transcranial Doppler ultrasonography to assess language lateralisation: Influence of task and difficulty level

    PubMed Central

    Badcock, Nicholas A.; Nye, Abigail; Bishop, Dorothy V. M.

    2011-01-01

    Language is lateralised to the left hemisphere in most people, but it is unclear whether the same degree and direction of lateralisation is found for all verbal tasks and whether laterality is affected by task difficulty. We used functional transcranial Doppler ultrasonography (fTCD) to assess the lateralisation of language processing in 27 young adults using three tasks: word generation (WG), auditory naming (AN), and picture story (PS). WG and AN are active tasks requiring behavioural responses whereas PS is a passive task that involves listening to an auditory story accompanied by pictures. We also examined the effect of task difficulty by a post hoc behavioural categorisation of trials in the WG task and a word frequency manipulation in the AN task. fTCD was used to measure task-dependent blood flow velocity changes in the left and right middle cerebral arteries. All of these tasks were significantly left lateralised: WG, 77% of individuals left, 5% right; AN, 72% left: 4% right; PS, 56% left: 0% right. There were significant positive relationships between WG and AN (r = 0.56) as well as AN and PS (r = .76) but not WG and PS (r = −0.22). The task difficulty manipulation affected accuracy in both WG and AN tasks, as well as reaction time in the AN task, but did not significantly influence laterality indices in either task. It is concluded that verbal tasks are not interchangeable when assessing cerebral lateralisation, but that differences between tasks are not a consequence of task difficulty. PMID:23098198

  19. Diagnosing erectile dysfunction: the penile dynamic colour duplex ultrasound revisited.

    PubMed

    Aversa, A; Bruzziches, R; Spera, G

    2005-12-01

    A number of disease processes of the penis including Peyronie's disease, priapism, penile fractures and tumors are clearly visualized with ultrasound. Diagnostic evaluation of erectile dysfunction (ED) by penile dynamic colour-duplex Doppler ultrasonography (D-CDDU) is actually considered a second level approach to ED patients because of the fact that intracavernous injections test IV with prostaglandin-E(1) may provide important information about the patients' erectile capacity. However, no direct vascular imaging and a high percentage of false negative diagnoses of vasculogenic ED are its major pitfalls and subsequent treatment decisions remain quite limited. The occurrence of ED and its sentinel relationship to cardiovascular disease has prompted more accurate vascular screening in all patients even in the absence of cardiovascular risk factors. The sonographic evaluation of the intima-media thickness of the carotid arteries may sometimes represent an early manifestation of diffuse atherosclerotic disease and endothelial damage. This latter finding is often the cause of failure to oral agents, i.e. phosphodiesterase inhibitors, because of inability of the dysfunctional endothelium to release nitric oxide. D-CDDU represents an accurate tool to investigate cavernous artery inflow and venous leakage when compared with more invasive diagnostic techniques i.e. selective arteriography and dynamic infusion cavernosometry along with cavernosography.

  20. Accurate evaluation of axillary sentinel lymph node metastasis using contrast-enhanced ultrasonography with Sonazoid in breast cancer: a preliminary clinical trial.

    PubMed

    Matsuzawa, Fumihiko; Omoto, Kiyoka; Einama, Takahiro; Abe, Hironori; Suzuki, Takashi; Hamaguchi, Jun; Kaga, Terumi; Sato, Mami; Oomura, Masako; Takata, Yumiko; Fujibe, Ayako; Takeda, Chie; Tamura, Etsuya; Taketomi, Akinobu; Kyuno, Kenichi

    2015-01-01

    Breast cancer is the most common type of cancer in women. The 5-year survival rate in patients with breast cancer ranges from 74 to 82 %. Sentinel lymph node biopsy has become an alternative to axillary lymph node dissection for nodal staging. We evaluated the detection of the sentinel lymph node and metastasis of the lymph node using contrast enhanced ultrasonography with Sonazoid. Between December 2013 and May 2014, 32 patients with operable breast cancer were enrolled in this study. We evaluated the detection of axillary sentinel lymph nodes and the evaluation of axillary lymph nodes metastasis using contrast enhanced computed tomography, color Doppler ultrasonography and contrast enhanced ultrasonography with Sonazoid. All the sentinel lymph nodes were identified, and the sentinel lymph nodes detected by contrast enhanced ultrasonography with Sonazoid corresponded with those detected by computed tomography lymphography and indigo carmine method. The detection of metastasis based on contrast enhanced computed tomography were sensitivity 20.0 %, specificity 88.2 %, PPV 60.0 %, NPV 55.6 %, accuracy 56.3 %. Based on color Doppler ultrasonography, the results were sensitivity 36.4 %, specificity 95.2 %, PPV 80.0 %, NPV 74.1 %, accuracy 75.0 %. Based on contrast enhanced ultrasonography with Sonazoid, the results were sensitivity 81.8 %, specificity 95.2 %, PPV 90.0 %, NPV 90.9 %, accuracy 90.6 %. The results suggested that contrast enhanced ultrasonography with Sonazoid was the most accurate among the evaluations of these modalities. In the future, we believe that our method would take the place of conventional sentinel lymph node biopsy for an axillary staging method.

  1. Testing the relativistic Doppler boost hypothesis for supermassive black hole binary candidates

    NASA Astrophysics Data System (ADS)

    Charisi, Maria; Haiman, Zoltán; Schiminovich, David; D'Orazio, Daniel J.

    2018-06-01

    Supermassive black hole binaries (SMBHBs) should be common in galactic nuclei as a result of frequent galaxy mergers. Recently, a large sample of sub-parsec SMBHB candidates was identified as bright periodically variable quasars in optical surveys. If the observed periodicity corresponds to the redshifted binary orbital period, the inferred orbital velocities are relativistic (v/c ≈ 0.1). The optical and ultraviolet (UV) luminosities are expected to arise from gas bound to the individual BHs, and would be modulated by the relativistic Doppler effect. The optical and UV light curves should vary in tandem with relative amplitudes which depend on the respective spectral slopes. We constructed a control sample of 42 quasars with aperiodic variability, to test whether this Doppler colour signature can be distinguished from intrinsic chromatic variability. We found that the Doppler signature can arise by chance in ˜20 per cent (˜37 per cent) of quasars in the nUV (fUV) band. These probabilities reflect the limited quality of the control sample and represent upper limits on how frequently quasars mimic the Doppler brightness+colour variations. We performed separate tests on the periodic quasar candidates, and found that for the majority, the Doppler boost hypothesis requires an unusually steep UV spectrum or an unexpectedly large BH mass and orbital velocity. We conclude that at most approximately one-third of these periodic candidates can harbor Doppler-modulated SMBHBs.

  2. Implementation of a Process for Initial Transcranial Doppler Ultrasonography in Children With Sickle Cell Anemia

    PubMed Central

    Crosby, Lori E.; Joffe, Naomi E.; Davis, Blair; Quinn, Charles T.; Shook, Lisa; Morgan, Darice; Simmons, Kenya; Kalinyak, Karen A.

    2016-01-01

    Stroke, a devastating complication of sickle cell anemia (SCA), can cause irreversible brain injury with physical and cognitive deficits. Transcranial Doppler ultrasonography (TCD) is a non-invasive tool for identifying children with SCA at highest risk of stroke. National guidelines recommend that TCD screening begin at age 2 years, yet there is research to suggest less than half of young children undergo screening. The purpose of this project was to use quality improvement methods to improve the proportion of patients aged 24–27 months who successfully completed their initial TCD from 25% to 75% by December 31, 2013. Quality improvement methods (e.g., process mapping, simplified failure mode effect analysis, and plan–do–study–act cycles) were used to develop and test processes for identifying eligible patients, scheduling TCDs, preparing children and families for the first TCD, and monitoring outcomes (i.e., TCD protocol). Progress was tracked using a report of eligible patients and a chart showing the age in months for the first successful TCD (population metric). As of December 2013, 100% of eligible patients successfully completed their initial TCD screen; this improvement was maintained for the next 20 months. In November 2014, a Welch’s one-way ANOVA was conducted. Results showed a statistically significant difference between the average age of first TCD for eligible patients born in 2009 and eligible patients born during the intervention period (2010–2013; F[1,11.712]=16.03, p=0.002). Use of quality improvement methods to implement a TCD protocol was associated with improved TCD screening rates in young children with SCA. PMID:27320459

  3. Implementation of a Process for Initial Transcranial Doppler Ultrasonography in Children With Sickle Cell Anemia.

    PubMed

    Crosby, Lori E; Joffe, Naomi E; Davis, Blair; Quinn, Charles T; Shook, Lisa; Morgan, Darice; Simmons, Kenya; Kalinyak, Karen A

    2016-07-01

    Stroke, a devastating complication of sickle cell anemia (SCA), can cause irreversible brain injury with physical and cognitive deficits. Transcranial Doppler ultrasonography (TCD) is a non-invasive tool for identifying children with SCA at highest risk of stroke. National guidelines recommend that TCD screening begin at age 2 years, yet there is research to suggest less than half of young children undergo screening. The purpose of this project was to use quality improvement methods to improve the proportion of patients aged 24-27 months who successfully completed their initial TCD from 25% to 75% by December 31, 2013. Quality improvement methods (e.g., process mapping, simplified failure mode effect analysis, and plan-do-study-act cycles) were used to develop and test processes for identifying eligible patients, scheduling TCDs, preparing children and families for the first TCD, and monitoring outcomes (i.e., TCD protocol). Progress was tracked using a report of eligible patients and a chart showing the age in months for the first successful TCD (population metric). As of December 2013, 100% of eligible patients successfully completed their initial TCD screen; this improvement was maintained for the next 20 months. In November 2014, a Welch's one-way ANOVA was conducted. Results showed a statistically significant difference between the average age of first TCD for eligible patients born in 2009 and eligible patients born during the intervention period (2010-2013; F[1,11.712]=16.03, p=0.002). Use of quality improvement methods to implement a TCD protocol was associated with improved TCD screening rates in young children with SCA. Copyright © 2016 American Journal of Preventive Medicine. Published by Elsevier Inc. All rights reserved.

  4. Blood flow velocity in monocular retinoblastoma assessed by color doppler

    PubMed Central

    Bonanomi, Maria Teresa B C; Saito, Osmar C; de Lima, Patricia Picciarelli; Bonanomi, Roberta Chizzotti; Chammas, Maria Cristina

    2015-01-01

    OBJECTIVE: To analyze the flow of retrobulbar vessels in retinoblastoma by color Doppler imaging. METHODS: A prospective study of monocular retinoblastoma treated by enucleation between 2010 and 2014. The examination comprised fundoscopy, magnetic resonance imaging, ultrasonography and color Doppler imaging. The peak blood velocities in the central retinal artery and central retinal vein of tumor-containing eyes (tuCRAv and tuCRVv, respectively) were assessed. The velocities were compared with those for normal eyes (nlCRAv and nlCRVv) and correlated with clinical and pathological findings. Tumor dimensions in the pathological sections were compared with those in magnetic resonance imaging and ultrasonography and were correlated with tuCRAv and tuCRVv. In tumor-containing eyes, the resistivity index in the central retinal artery and the pulse index in the central retinal vein were studied in relation to all variables. RESULTS: Eighteen patients were included. Comparisons between tuCRAv and nlCRAv and between tuCRVv and nlCRVv revealed higher velocities in tumor-containing eyes (p<0.001 for both), with a greater effect in the central retinal artery than in the central retinal vein (p=0.024). Magnetic resonance imaging and ultrasonography measurements were as reliable as pathology assessments (p=0.675 and p=0.375, respectively). A positive relationship was found between tuCRAv and the tumor volume (p=0.027). The pulse index in the central retinal vein was lower in male patients (p=0.017) and in eyes with optic nerve invasion (p=0.0088). CONCLUSIONS: TuCRAv and tuCRVv are higher in tumor-containing eyes than in normal eyes. Magnetic resonance imaging and ultrasonography measurements are reliable. The tumor volume is correlated with a higher tuCRAv and a reduced pulse in the central retinal vein is correlated with male sex and optic nerve invasion. PMID:26735219

  5. Is Doppler ultrasound useful for evaluating gestational trophoblastic disease?

    PubMed

    Lin, Lawrence H; Bernardes, Lisandra S; Hase, Eliane A; Fushida, Koji; Francisco, Rossana P V

    2015-12-01

    Doppler ultrasound is a non-invasive method for evaluating vascularization and is widely used in clinical practice. Gestational trophoblastic neoplasia includes a group of highly vascularized malignancies derived from placental cells. This review summarizes data found in the literature regarding the applications of Doppler ultrasound in managing patients with gestational trophoblastic neoplasia. The PubMed/Medline, Web of Science, Cochrane and LILACS databases were searched for articles published in English until 2014 using the following keywords: "Gestational trophoblastic disease AND Ultrasonography, Doppler." Twenty-eight articles met the inclusion criteria and were separated into the 4 following groups according to the aim of the study. (1) Doppler ultrasound does not seem to be capable of differentiating partial from complete moles, but it might be useful when evaluating pregnancies in which a complete mole coexists with a normal fetus. (2) There is controversy in the role of uterine artery Doppler velocimetry in the prediction of development of gestational trophoblastic neoplasia. (3) Doppler ultrasound is a useful tool in the diagnosis of gestational trophoblastic neoplasia because abnormal myometrial vascularization and lower uterine artery Doppler indices seem to be correlated with invasive disease. (4) Lower uterine artery Doppler indices in the diagnosis of gestational trophoblastic neoplasia are associated with methotrexate resistance and might play a role in prognosis. Several studies support the importance of Doppler ultrasound in the management of patients with gestational trophoblastic neoplasia, particularly the role of Doppler velocimetry in the prediction of trophoblastic neoplasia and the chemoresistance of trophoblastic tumors. Doppler findings should be used as ancillary tools, along with human chorionic gonadotropin assessment, in the diagnosis of gestational trophoblastic neoplasia.

  6. Strain ratio ultrasound elastography increases the accuracy of colour-Doppler ultrasound in the evaluation of Thy-3 nodules. A bi-centre university experience.

    PubMed

    Cantisani, Vito; Maceroni, Piero; D'Andrea, Vito; Patrizi, Gregorio; Di Segni, Mattia; De Vito, Corrado; Grazhdani, Hektor; Isidori, Andrea M; Giannetta, Elisa; Redler, Adriano; Frattaroli, Fabrizio; Giacomelli, Laura; Di Rocco, Giorgio; Catalano, Carlo; D'Ambrosio, Ferdinando

    2016-05-01

    To assess whether ultrasound elastography (USE) with strain ratio increases diagnostic accuracy of Doppler ultrasound in further characterisation of cytologically Thy3 thyroid nodules. In two different university diagnostic centres, 315 patients with indeterminate cytology (Thy3) in thyroid nodules aspirates were prospectively evaluated with Doppler ultrasound and strain ratio USE before surgery. Ultrasonographic features were analysed separately and together as ultrasound score, to assess sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV). Receiver operating characteristic (ROC) curves to identify optimal cut-off value of the strain ratio were also provided. Diagnosis on a surgical specimen was considered the standard of reference. Higher strain ratio values were found in malignant nodules, with an optimum strain ratio cut-off of 2.09 at ROC analysis. USE with strain ratio showed 90.6% sensitivity, 93% specificity, 82.8% PPV, 96.4% NPV, while US score yielded a sensitivity of 52.9%, specificity of 84.3%, PPV 55.6% and NPV 82.9%. The diagnostic gain with strain ratio was statistically significant as proved by ROC areas, which was 0.9182 for strain ratio and 0.6864 for US score. USE with strain ratio should be considered a useful additional tool to colour-Doppler US, since it improves characterisation of thyroid nodules with indeterminate cytology. • Strain ratio measurements improve differentiation of thyroid nodules with indeterminate cytology • Elastography with strain ratio is more reliable than ultrasound features and ultrasound score • Strain ratio may help to better select patients with Thy 3 nodules candidate for surgery.

  7. Cerebral High-Intensity Transient Signals during Pediatric Cardiac Catheterization: A Pilot Study Using Transcranial Doppler Ultrasonography.

    PubMed

    LaRovere, Kerri L; Kapur, Kush; McElhinney, Doff B; Razumovsky, Alexander; Kussman, Barry D

    2017-07-01

    Cerebral emboli are one potential cause of acute brain injury in children with congenital heart disease (CHD) undergoing cardiac catheterization. In this pilot study using transcranial Doppler (TCD) ultrasonography, we sought to evaluate the incidence, burden, and circumstances of cerebral high-intensity transient signals (HITS), presumably representing emboli, during pediatric cardiac catheterization. Emboli monitoring of the right middle cerebral artery was performed in five children. HITS, counted offline, were defined as unidirectional signals associated with audible "chirp" and sinusoidal correlation. HITS were grouped as single, >10 HITS ("cluster"), or HITS "with curtain effect" per 3-5 cardiac cycles. Cerebral blood flow velocity (CBFV) and pulsatility index (PI) were recorded after anesthetic induction (baseline). Total HITS in the cohort was 1,697 (790 single HITS, 606 HITS within clusters, and 301 HITS within curtains). HITS in clusters and curtains comprised 53% (907/1,697) of total HITS, and occurred in 44 clusters/curtains. Events associated with clusters/curtains included left ventricular angiography (39%; 17/44), right ventricular angiography (16%; 7/44), device placement (16%; 7/44), heparin bolus (9%; 4/44), pulmonary artery angiography (9%; 4/44), venous access (5%; 2/44), right atrial angiography (2%; 1/44), arterial access (2%; 1/44), and hemodynamic measurements (2%; 1/44). No patient had clinically detectable neurologic injury. HITS are common during pediatric cardiac catheterization, and associated with procedural factors. Whether curtains/clusters are worse than single, repetitive HITS is unknown. Larger studies are needed to determine whether HITS are a marker of risk of neurologic injury from emboli during pediatric cardiac catheterization. Copyright © 2017 by the American Society of Neuroimaging.

  8. Use of transesophageal Doppler ultrasonography in ventilated pediatric patients: derivation of cardiac output.

    PubMed

    Tibby, S M; Hatherill, M; Murdoch, I A

    2000-06-01

    To ascertain if cardiac output (CO) could be derived from blood flow velocity measured in the descending aorta of ventilated children by transesophageal Doppler ultrasonography (TED) without the need for direct aortic cross sectional area measurement, and to evaluate the ability of TED to follow changes in CO when compared with femoral artery thermodilution. Prospective, comparison study. A 16-bed pediatric intensive care unit of a university hospital. A total of 100 ventilated infants and children aged 4 days to 18 yrs (median age, 27 months). Diagnoses included postcardiac surgery (n = 58), sepsis/multiple organ failure (n = 32), respiratory disease (n = 5), and other (n = 5). A total of 55 patients were receiving inotropes or vasodilators. When patients were hemodynamically stable, a TED probe was placed into the distal esophagus to obtain optimal signal, and minute distance (MD) was recorded. Five consecutive MD measurements were made concurrently with five femoral artery thermodilution measurements, and the concurrent measurements were averaged. CO was then manipulated by fluid administration or inotrope adjustment, and the readings were repeated. Femoral artery thermodilution CO ranged from 0.32 to 9.19 L/min, (median, 2.46 L/min), and encompassed a wide range of high and low flow states. Theoretical consideration revealed the optimal TED estimate for CO to be (MD x patient height2 x 10(-7)). Linear regression analysis yielded a power function model such that: estimated CO = 1.158 x (MD x height2 x 10(-7))(0.785), r2 = 0.879, standard error of the estimate = 0.266. Inclusion of a correction factor for potential changes in aortic cross-sectional area with hypo- and hypertension did not appreciably improve the predictive value of the model. MD was able to follow percentage changes in CO, giving a mean bias of 0.87% (95% confidence interval -0.85% to 2.59%), and limits of agreement of +/- 16.82%. The median coefficient of variation for MD was 3.3%. TED provides

  9. Assessment: transcranial Doppler ultrasonography: report of the Therapeutics and Technology Assessment Subcommittee of the American Academy of Neurology.

    PubMed

    Sloan, M A; Alexandrov, A V; Tegeler, C H; Spencer, M P; Caplan, L R; Feldmann, E; Wechsler, L R; Newell, D W; Gomez, C R; Babikian, V L; Lefkowitz, D; Goldman, R S; Armon, C; Hsu, C Y; Goodin, D S

    2004-05-11

    To review the use of transcranial Doppler ultrasonography (TCD) and transcranial color-coded sonography (TCCS) for diagnosis. The authors searched the literature for evidence of 1) if TCD provides useful information in specific clinical settings; 2) if using this information improves clinical decision making, as reflected by improved patient outcomes; and 3) if TCD is preferable to other diagnostic tests in these clinical situations. TCD is of established value in the screening of children aged 2 to 16 years with sickle cell disease for stroke risk (Type A, Class I) and the detection and monitoring of angiographic vasospasm after spontaneous subarachnoid hemorrhage (Type A, Class I to II). TCD and TCCS provide important information and may have value for detection of intracranial steno-occlusive disease (Type B, Class II to III), vasomotor reactivity testing (Type B, Class II to III), detection of cerebral circulatory arrest/brain death (Type A, Class II), monitoring carotid endarterectomy (Type B, Class II to III), monitoring cerebral thrombolysis (Type B, Class II to III), and monitoring coronary artery bypass graft operations (Type B to C, Class II to III). Contrast-enhanced TCD/TCCS can also provide useful information in right-to-left cardiac/extracardiac shunts (Type A, Class II), intracranial occlusive disease (Type B, Class II to IV), and hemorrhagic cerebrovascular disease (Type B, Class II to IV), although other techniques may be preferable in these settings.

  10. Neurilemmoma of the glans penis: ultrasonography and magnetic resonance imaging findings.

    PubMed

    Jung, Dae Chul; Hwang, Sung Il; Jung, Sung Il; Kim, Sun Ho; Kim, Seung Hyup

    2006-01-01

    Neurilemmoma of the glans penis is rare, and no imaging findings have been reported. A case of neurilemmoma of the glans penis is presented. Ultrasonography (US) and magnetic resonance imaging revealed a well-defined small mass in the glans penis. The mass appeared hypoechoic on gray-scale US and hypervascular on color Doppler US. Magnetic resonance imaging revealed high signal intensity of the mass on a T2-weighted image and strong enhancement on a contrast-enhanced T1-weighted image.

  11. Systolic arterial blood pressure estimated by mitral regurgitation velocity, high definition oscillometry, and Doppler ultrasonography in dogs with naturally occurring degenerative mitral valve disease.

    PubMed

    Hanzlicek, A S; Baumwart, R D; Payton, M E

    2016-09-01

    To determine if systolic blood pressure estimated by mitral regurgitation (MR) velocity can be used interchangeably with that estimated by high definition oscillometry (HDO) and Doppler ultrasonography (DU) in dogs with naturally occurring mitral valve disease (MVD). Forty-nine client-owned dogs with naturally occurring MVD. This is a retrospective study. Medical records were reviewed and dogs with MR caused by degenerative MVD were included if systolic blood pressure was estimated from MR velocity determined by continuous wave Doppler (CW), DU and HDO at the same visit. A Pearson product moment correlation coefficient was determined for each combination of measures and tested for significance with a paired t-test. Limits of agreement between 2 measures were determined by the 95% confidence interval of the average difference of the means and illustrated by Bland-Altman plots. Systolic pressure estimated from CW was significantly but only moderately correlated to DU (r = 0.42, p=0.0015) and HDO (r = 0.40, p=0.0021). Pressure estimated from DU was significantly but only moderately correlated to HDO (r = 0.57, p≤0.0001). Limits of agreement were wide for all measures including DU and CW (-61.9to 44.6 mmHg), HDO and CW (-65.2to 26.9 mmHg), and HDO and DU (-63.1 to 42.06 mmHg). Systolic blood pressure estimated by CW cannot be used interchangeably with HDO or DU in dogs with naturally occurring MVD. Copyright © 2016 Elsevier B.V. All rights reserved.

  12. Ultrasonography of ovarian masses using a pattern recognition approach

    PubMed Central

    Jung, Sung Il

    2015-01-01

    As a primary imaging modality, ultrasonography (US) can provide diagnostic information for evaluating ovarian masses. Using a pattern recognition approach through gray-scale transvaginal US, ovarian masses can be diagnosed with high specificity and sensitivity. Doppler US may allow ovarian masses to be diagnosed as benign or malignant with even greater confidence. In order to differentiate benign and malignant ovarian masses, it is necessary to categorize ovarian masses into unilocular cyst, unilocular solid cyst, multilocular cyst, multilocular solid cyst, and solid tumor, and then to detect typical US features that demonstrate malignancy based on pattern recognition approach. PMID:25797108

  13. Use of Audible and Chart-recorded Ultrasonography to Monitor Fetal Heart Rate and Uterine Blood Flow Parameters in Cattle

    USDA-ARS?s Scientific Manuscript database

    The objective of the present study was to evaluate the use of audible chart-recorded doppler ultrasonography (DUS) to monitor both uterine blood flow and fetal heart rate (FHR) during pregnancy in dairy cattle. Possible applications of DUS include the monitoring of fetal distress when a pregnancy be...

  14. Relationship between colour flow Doppler sonographic assessment of corpus luteum activity and progesterone concentrations in mares after embryo transfer.

    PubMed

    Brogan, P T; Henning, H; Stout, T A E; de Ruijter-Villani, M

    2016-03-01

    Colour-flow Doppler sonography has been described as a means of assessing corpus luteum (CL) function rapidly, because area of luteal blood vessels correlates well with circulating progesterone (P4) concentrations [P4] in oestrous cycling mares. The aim of this study was to assess the relationships between CL size and vascularity, and circulating [P4] during early pregnancy in mares, and to determine whether luteal blood flow was a useful aid for selecting an embryo transfer recipient. Equine embryos (n=48) were recovered 8 days after ovulation and were transferred to available recipient mares as part of a commercial program with the degree of synchrony in timing of recipient ovulation ranging from 1 day before to 4 days after the donor. Immediately prior to embryo transfer (ET), maximum CL cross-section and blood vessel areas were assessed sonographically, and jugular blood was collected to measure plasma [P4]. Sonographic measurements and jugular blood collection were repeated at day 4 after ET for all mares, and again at days 11, 18 and 25 after ET in mares that were pregnant. The number of grey-scale and colour pixels within the CL was subsequently quantified using ImageJ software. The CL blood flow correlated significantly but weakly with plasma [P4] on the day of transfer and on day 4 after ET in all mares, and on days 11 and 25 after ET in pregnant mares (r=0.30-0.36). The CL area and plasma [P4] were also correlated on each day until day 11 after ET (r=0.49-0.60). The CL colour pixel area decreased significantly after day 18, whereas CL area was already decreasing by day 4 after ET. The CL area, area of blood flow, or [P4] was predictive of pregnancy. Findings in the present study suggest that both CL area and blood flow are correlated with circulating [P4] at the time of transfer and in early pregnancy. Evaluation of the CL using B-mode or CF sonography, although practical, provides no improvement in the selection of recipients or prediction of pregnancy

  15. Power Doppler ultrasonography and synovitis: correlating ultrasound imaging with histopathological findings and evaluating the performance of ultrasound equipments.

    PubMed

    Koski, J M; Saarakkala, S; Helle, M; Hakulinen, U; Heikkinen, J O; Hermunen, H

    2006-12-01

    To examine the validity of power Doppler ultrasound imaging to identify synovitis, using histopathology as gold standard, and to assess the performance of ultrasound equipments. 44 synovial sites in small and large joints, bursae and tendon sheaths were depicted with ultrasound. A synovial biopsy was performed on the site depicted and a synovial sample was taken for histopathological evaluation. The performance of three ultrasound devices was tested using flow phantoms. A positive Doppler signal was detected in 29 of 35 (83%) of the patients with active histological inflammation. In eight additional samples, histological examination showed other pathological synovial findings and a Doppler signal was detected in five of them. No significant correlation was found between the amount of Doppler signal and histological synovitis score (r = 0.239, p = NS). The amount of subsynovial infiltration of polymorphonuclear leucocytes and surface fibrin correlated significantly with the amount of power Doppler signal: r = 0.397 (p<0.01) and 0.328 (p<0.05), respectively. The ultrasound devices differed in showing the smallest detectable flow. A negative Doppler signal does not exclude the possibility of synovitis. A positive Doppler signal in the synovium is an indicator of an active synovial inflammation in patients. A Doppler signal does not correlate with the extent of the inflammation and it can also be seen in other synovial reactions. It is important that the quality measurements of ultrasound devices are reported, because the results should be evaluated against the quality of the device used.

  16. Echocardiography.

    PubMed Central

    Chambers, J. B.; Monaghan, M. J.; Jackson, G.

    1988-01-01

    Imaging echocardiography is an important extension of the clinical examination and will answer most questions in an emergency-for example, whether an enlarged cardiac shadow on the chest radiograph represents ventricular dilatation or an effusion. Doppler ultrasonography is essential for hospitals with an interest in cardiology because it provides direct haemodynamic data that are complementary to imaging. It requires more skill than imaging and may also be time consuming. Colour flow Doppler mapping is speedy and simple to use and aids the interpretation of continuous wave Doppler. It is therefore a natural companion to conventional Doppler, but there would have to be a high clinical load to justify its purchase. Images FIG 3 FIG 4 FIG 4 FIG 5 FIG 6 PMID:3143434

  17. Retrobulbar ocular blood flow changes measured by colour Doppler imaging after intra-arterial chemotherapy in retinoblastoma.

    PubMed

    Xue, Kang; Liu, Ailin; Hui, Ren; Zhang, Jing; Qian, Jiang

    2017-10-01

    To evaluate the effects of intra-arterial chemotherapy on retrobulbar blood flow parameters in patients with retinoblastoma. 20 eyes of 10 patients with unilateral retinoblastoma that were treated with intra-arterial chemotherapy were evaluated using colour Doppler imaging. The peak systolic and end-diastolic velocities of the ophthalmic, central retinal and posterior ciliary arteries were determined. The pulsatility and resistance indices were calculated automatically. The treated eye was compared with the untreated (control) eye and with itself before and after intra-arterial chemotherapy. When comparing the retinoblastoma-containing eyes with the contralateral normal eyes, the peak systolic and end-diastolic velocities of the central retinal artery were significantly higher in the tumorous eyes than in the normal eyes before intra-arterial chemotherapy. Moreover, the peak systolic and end-diastolic velocities in the posterior ciliary and central retinal arteries were significantly decreased after intra-arterial chemotherapy in the tumorous eyes (p<0.05). There were no statistically significant differences in the other parameters. Our results suggest that intra-arterial chemotherapy has a measurable effect on the retrobulbar blood flow, which can cause a decrease in the peak systolic and end-diastolic velocities in the posterior ciliary and central retinal arteries. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  18. Christian Andreas Doppler: A legendary man inspired by the dazzling light of the stars

    PubMed Central

    Katsi, V; Felekos, I; Kallikazaros, I

    2013-01-01

    Christian Andreas Doppler is renowned primarily for his revolutionary theory of the Doppler effect, which has deeply influenced many areas of modern science and technology, including medicine. His work has laid the foundations for modern ultrasonography and his ideas are still inspiring discoveries more than a hundred years after his death. Doppler may well earn the title of Homo Universalis for his broad knowledge of physics, mathematics and astronomy and most of all for his indefatigable investigations for new ideas and his ingenious mind. According to Bolzano: “It is hard to believe how fruitful a genius Austria has in this man”. His legacy of scientific achievement have seen Doppler honoured in the later years on coinage and money, names of streets, educational institutions, rock groups, even of a lunar crater; while the ultimate tribute to his work is the countless references to the homonymous medical eponym. PMID:24376313

  19. B-mode and Doppler sonography of the mammary glands in dairy goats for mastitis diagnosis.

    PubMed

    Santos, Vjc; Simplício, K; Sanchez, D; Coutinho, L; Teixeira, P; Barros, F; Almeida, V; Rodrigues, L; Bartlewski, P; Oliveira, M; Feliciano, M; Vicente, W

    2015-04-01

    This study aimed to evaluate the sonographic characteristics of the udder and teats and to determine the Doppler indexes of mammary artery in healthy and undergoing subclinical and clinical mastitis goats. Thirty animals among Saanen and Alpine Brown goats were arranged in three groups, healthy goats (HG), goats with subclinical mastitis (SMG) and goats with clinical mastitis (CMG). Using the B-mode, the sonographic characteristics (echotexture and echogenicity) and biometry (diameter and area of the udder cistern, diameter and area of the teat cistern and thickness of the teat wall) were evaluated. Using Doppler ultrasonography, the vascular indexes of the mammary artery were obtained. It was observed hyperechogenicity with solid component in the gland cistern when comparing animals with clinical mastitis and healthy mammary tissue. Regarding the echotexture of the breast tissue, there was heterogeneity in the mammary parenchyma on the three groups, for the milk, it was observed homogeneity for animals on HG and SMG and heterogeneity for animals on CMG. Grey-scale quantitative assessment revealed increase in echogenicity (mean value) for all the structures when comparing the three groups. Biometry did not reveal statistical difference between groups, for none of the evaluated structures. Doppler examination of the mammary artery showed the decrease of end diastolic velocity and raise of pulsatility index between groups. The association of B-mode and Doppler ultrasonography is useful for the evaluation of the udder of dairy goats with mastitis. It is a sensitive and specific method for the study of this disease. Doppler mode was unable to establish reliable criteria for diagnosis of subclinical mastitis. Moreover, the quantification of echogenicity is a useful technique for the evaluation of the milk in animals with mastitis; therefore, it is suggested that it can be used as complementary technique for the diagnosis of mastitis in goats. © 2015 Blackwell Verlag

  20. Tissue Doppler imaging and echo-Doppler findings associated with a mitral valve stenosis with an immobile posterior valve leaflet in a bull terrier.

    PubMed

    Tidholm, A; Nicolle, A P; Carlos, C; Gouni, V; Caruso, J L; Pouchelon, J L; Chetboul, V

    2004-04-01

    A mitral valve stenosis was diagnosed in a 2-year-old female Bull Terrier by use of two-dimensional (2-D) and M-mode echocardiography, colour-flow imaging and spectral Doppler examinations. Tissue Doppler Imaging was also performed to assess the segmental radial myocardial motion. The mitral valve stenosis was characterized by a decreased mitral orifice area/left ventricle area ratio (0.14), an increased early diastolic flow velocity (E wave = 1.9 m/s), a prolonged pressure half-time (106 ms) and a decreased E-F slope (4.5 cm/s) on pulsed-wave Doppler examination. This mitral stenosis was associated with an immobile posterior leaflet, as seen on 2-D and M-mode echocardiography. Immobility of the posterior mitral leaflet is considered to be a rare finding in humans and, to our knowledge, has not been precisely documented in dogs with mitral valve stenosis.

  1. Penile Doppler sonographic and clinical characteristics in Peyronie's disease and/or erectile dysfunction: an analysis of 1500 men with male sexual dysfunction.

    PubMed

    Chung, Eric; Yan, Hanmu; De Young, Ling; Brock, Gerald B

    2012-10-01

    What's known on the subject? and What does the study add? Penile colour Doppler ultrasonography (CDU) can be an invaluable investigative tool to characterize penile abnormalities to complement clinical history and physical examination in the evaluation of men with Peyronie's disease (PD) and/or erectile dysfunction (ED). Although CDU findings between men with PD and those with ED were not markedly different, subtle differences were observed. The classic penile CDU findings in men with PD comprise tunical thickening, intracavernosal fibrosis, septal fibrosis and intracavernosal calcification, while, in men with ED, low peak systolic velocity and high end-diastolic velocity are found on penile haemodynamics. Previously published studies have focused predominantly on either ED or PD exclusively, or examine the risk of progression to ED in the PD population. To our knowledge, this is the largest and most comprehensive analysis of penile CDU and clinical findings in men with PD and/or ED. The large sample size and multivariable analysis allow meaningful interpretation of the results. This study has found some substantial differences in the penile CDU findings of men with PD and/or ED that have not previously been reported. Although the risk factors of ED may be greater than those for PD, there is crossover in age, cardiovascular risk factors, trauma and penile CDU findings in men with PD and/or ED. To explore the differences in penile colour Doppler ultrasonography (CDU) findings between men with Peyronie's disease (PD) and those with erectile dysfunction (ED). Patients presenting with PD and/or ED who underwent penile CDU were recruited to the study. Patient demographics, comorbidities, International Index of Erectile Function-5 scores, previous therapies and physical findings were documented. Penile curvature, presence of tunical thickening, septal fibrosis, intracavernosal fibrosis and calcification, and cavernosal vascular status were recorded. A total of 1500 men

  2. Pulse Doppler ultrasound as a tool for the diagnosis of chronic testicular dysfunction in stallions

    PubMed Central

    Ortiz-Rodriguez, Jose M.; Anel-Lopez, Luis; Martín-Muñoz, Patricia; Álvarez, Mercedes; Gaitskell-Phillips, Gemma; Anel, Luis; Rodríguez-Medina, Pedro; Peña, Fernando J.

    2017-01-01

    Testicular function is particularly susceptible to vascular insult, resulting in a negative impact on sperm production and quality of the ejaculate. A prompt diagnosis of testicular dysfunction enables implementation of appropriate treatment, hence improving fertility forecasts for stallions. The present research aims to: (1) assess if Doppler ultrasonography is a good tool to diagnose stallions with testicular dysfunction; (2) to study the relationship between Doppler parameters of the testicular artery and those of sperm quality assessed by flow cytometry and (3) to establish cut off values to differentiate fertile stallions from those with pathologies causing testicular dysfunction. A total of 10 stallions (n: 7 healthy stallions and n: 3 sub-fertile stallions) were used in this study. Two ejaculates per stallion were collected and preserved at 5°C in a commercial extender. The semen was evaluated at T0, T24 and T48h by flow cytometry. Integrity and viability of sperm (YoPro®-1/EthD-1), mitochondrial activity (MitoTracker® Deep Red FM) and the DNA fragmentation index (Sperm Chromatin Structure Assay) were assessed. Doppler parameters were measured at three different locations on the testicular artery (Supratesticular artery (SA); Capsular artery (CA) and Intratesticular artery (IA)). The Doppler parameters calculated were: Resistive Index (RI), Pulsatility Index (PI), Peak Systolic Velocity (PSV), End Diastolic Velocity (EDV), Time Average Maximum Velocity (TAMV), Total Arterial Blood Flow (TABF) and TABF rate. The capsular artery was the most reliable location to carry out spectral Doppler assessment, since blood flow parameters of this artery were most closely correlated with sperm quality parameters. Significant differences in all the Doppler parameters studied were observed between fertile and subfertile stallions (p ≤ 0.05). The principal components analysis assay determined that fertile stallions are characterized by high EDV, TAMV, TABF and TABF rate

  3. Fundamentals of diagnostic ultrasonography.

    PubMed

    Noce, J P

    1990-01-01

    Diagnostic ultrasonography uses acoustical waves in the frequency range of 1 to 20 MHz. These waves obey Snell's law of reflection and refraction, which are rules ordinary to wave behavior. In ultrasound, the analogy to momentum is acoustic impedance. The acoustic impedance, Z, is equal to the density, p, times velocity, v. The ultrasound transducer converts electrical energy into ultrasound energy and vice versa. The transducer usually consists of a piezoelectric crystal composed of such ceramic materials as barium titanate, lead titanate, zirconate, or lead metaniobate. Five basic ultrasonic scanning modes play the major roles in clinical applications. A-mode, or amplitude-mode, scanning measures the tissue discontinuity along the scan axis. B-mode scanning produces a two-dimensional image of the tissue under study by combining A-mode signals from various directions through mechanical transducer scanning. M-mode, or time motion scanning, is an extension of the A-mode approach in which a single stationary transducer is used. The depth of the echo is displayed on the vertical axis; the brightness of the oscilloscope display is modulated by the echo amplitude. Real-time scanning, or rapid B-scanning, techniques provide continuous data acquisition at a rate sufficient to give the impression of the instantaneous motion of moving structures. Doppler scanning relies on the presence of motion. The Doppler effect occurs when there is relative motion between the source of sound and the receiver of the sound, causing a change in the detected frequency of the sound source.

  4. Interactions between colour and synaesthetic colour: an effect of simultaneous colour contrast on synaesthetic colours.

    PubMed

    Nijboer, Tanja C W; Gebuis, Titia; te Pas, Susan F; van der Smagt, Maarten J

    2011-01-01

    We investigated whether simultaneous colour contrast affects the synaesthetic colour experience and normal colour percept in a similar manner. We simultaneously presented a target stimulus (i.e. grapheme) and a reference stimulus (i.e. hash). Either the grapheme or the hash was presented on a saturated background of the same or opposite colour category as the synaesthetic colour and the other stimulus on a grey background. In both conditions, grapheme-colour synaesthetes were asked to colour the hash in a colour similar to the synaesthetic colour of the grapheme. Controls that were pair-matched to the synaesthetes performed the same experiment, but for them, the grapheme was presented in the colour induced by the grapheme in synaesthetes. When graphemes were presented on a grey and the hash on a coloured background, a traditional simultaneous colour-contrast effect was found for controls as well as synaesthetes. When graphemes were presented on colour and the hash on grey, the controls again showed a traditional simultaneous colour-contrast effect, whereas the synaesthetes showed the opposite effect. Our results show that synaesthetic colour experiences differ from normal colour perception; both are susceptible to different surrounding colours, but not in a comparable manner. Copyright © 2010 Elsevier Ltd. All rights reserved.

  5. Effects of memory colour on colour constancy for unknown coloured objects.

    PubMed

    Granzier, Jeroen J M; Gegenfurtner, Karl R

    2012-01-01

    The perception of an object's colour remains constant despite large variations in the chromaticity of the illumination-colour constancy. Hering suggested that memory colours, the typical colours of objects, could help in estimating the illuminant's colour and therefore be an important factor in establishing colour constancy. Here we test whether the presence of objects with diagnostical colours (fruits, vegetables, etc) within a scene influence colour constancy for unknown coloured objects in the scene. Subjects matched one of four Munsell papers placed in a scene illuminated under either a reddish or a greenish lamp with the Munsell book of colour illuminated by a neutral lamp. The Munsell papers were embedded in four different scenes-one scene containing diagnostically coloured objects, one scene containing incongruent coloured objects, a third scene with geometrical objects of the same colour as the diagnostically coloured objects, and one scene containing non-diagnostically coloured objects (eg, a yellow coffee mug). All objects were placed against a black background. Colour constancy was on average significantly higher for the scene containing the diagnostically coloured objects compared with the other scenes tested. We conclude that the colours of familiar objects help in obtaining colour constancy for unknown objects.

  6. Applying colour science in colour design

    NASA Astrophysics Data System (ADS)

    Luo, Ming Ronnier

    2006-06-01

    Although colour science has been widely used in a variety of industries over the years, it has not been fully explored in the field of product design. This paper will initially introduce the three main application fields of colour science: colour specification, colour-difference evaluation and colour appearance modelling. By integrating these advanced colour technologies together with modern colour imaging devices such as display, camera, scanner and printer, some computer systems have been recently developed to assist designers for designing colour palettes through colour selection by means of a number of widely used colour order systems, for creating harmonised colour schemes via a categorical colour system, for generating emotion colours using various colour emotional scales and for facilitating colour naming via a colour-name library. All systems are also capable of providing accurate colour representation on displays and output to different imaging devices such as printers.

  7. Latin American Consensus on the use of transcranial Doppler in the diagnosis of brain death

    PubMed Central

    2014-01-01

    Transcranial Doppler evaluates cerebral hemodynamics in patients with brain injury and is a useful technical tool in diagnosing cerebral circulatory arrest, usually present in the brain-dead patient. This Latin American Consensus was formed by a group of 26 physicians experienced in the use of transcranial Doppler in the context of brain death. The purpose of this agreement was to make recommendations regarding the indications, technique, and interpretation of the study of transcranial ultrasonography in patients with a clinical diagnosis of brain death or in the patient whose clinical diagnosis presents difficulties; a working group was formed to enable further knowledge and to strengthen ties between Latin American physicians working on the same topic. A review of the literature, concepts, and experiences were exchanged in two meetings and via the Internet. Questions about pathophysiology, equipment, techniques, findings, common problems, and the interpretation of transcranial Doppler in the context of brain death were answered. The basic consensus statements are the following: cerebral circulatory arrest is the final stage in the evolution of progressive intracranial hypertension, which is visualized with transcranial Doppler as a "pattern of cerebral circulatory arrest". The following are accepted as the standard of cerebral circulatory arrest: reverberant pattern, systolic spikes, and absence of previously demonstrated flow. Ultrasonography should be used - in acceptable hemodynamic conditions - in the anterior circulation bilaterally (middle cerebral artery) and in the posterior (basilar artery) territory. If no ultrasonographic images are found in any or all of these vessels, their proximal arteries are acceptable to be studied to look for a a pattern of cerebral circulatory arrest. PMID:25295818

  8. Effects of memory colour on colour constancy for unknown coloured objects

    PubMed Central

    Granzier, Jeroen J M; Gegenfurtner, Karl R

    2012-01-01

    The perception of an object's colour remains constant despite large variations in the chromaticity of the illumination—colour constancy. Hering suggested that memory colours, the typical colours of objects, could help in estimating the illuminant's colour and therefore be an important factor in establishing colour constancy. Here we test whether the presence of objects with diagnostical colours (fruits, vegetables, etc) within a scene influence colour constancy for unknown coloured objects in the scene. Subjects matched one of four Munsell papers placed in a scene illuminated under either a reddish or a greenish lamp with the Munsell book of colour illuminated by a neutral lamp. The Munsell papers were embedded in four different scenes—one scene containing diagnostically coloured objects, one scene containing incongruent coloured objects, a third scene with geometrical objects of the same colour as the diagnostically coloured objects, and one scene containing non-diagnostically coloured objects (eg, a yellow coffee mug). All objects were placed against a black background. Colour constancy was on average significantly higher for the scene containing the diagnostically coloured objects compared with the other scenes tested. We conclude that the colours of familiar objects help in obtaining colour constancy for unknown objects. PMID:23145282

  9. Pulsed-wave Doppler ultrasonographic evaluation of hepatic vein in dogs with tricuspid regurgitation

    PubMed Central

    Kim, Jaehwan; Kim, Soyoung

    2017-01-01

    This study was performed to identify the relationships between hepatic vein (HV) measurements, including flow velocity and waveform, using pulsed-wave (PW) Doppler ultrasonography, and the severity of tricuspid regurgitation (TR) in dogs. The study included 22 dogs with TR and 7 healthy dogs. The TR group was subdivided into 3 groups according to TR jet profile obtained by echocardiography. The hepatic venous waveform was obtained and classified into 3 types. A variety of HV measurements, including the maximal velocities of the atrial systolic, systolic (S), end ventricular systolic, and diastolic (D) waves and the ratio of the S- and D- wave velocities (S/D ratio), were acquired. TR severity was significantly correlated with the S- (r = −0.380, p = 0.042) and D- (r = 0.468, p = 0.011) wave velocities and the S/D ratio (r = −0.747, p < 0.001). Receiver operating characteristic curve analysis revealed the highest sensitivity and specificity for the S/D ratio (89% and 75%, respectively) at a threshold of 0.97 with excellent accuracy (AUC = 0.911, p < 0.001). In conclusion, PW Doppler ultrasonography of the HV can be used to identify the presence of significant TR and to classify TR severity in dogs. PMID:27515264

  10. Pulsed-wave Doppler ultrasonographic evaluation of hepatic vein in dogs with tricuspid regurgitation.

    PubMed

    Kim, Jaehwan; Kim, Soyoung; Eom, Kidong

    2017-03-30

    This study was performed to identify the relationships between hepatic vein (HV) measurements, including flow velocity and waveform, using pulsed-wave (PW) Doppler ultrasonography, and the severity of tricuspid regurgitation (TR) in dogs. The study included 22 dogs with TR and 7 healthy dogs. The TR group was subdivided into 3 groups according to TR jet profile obtained by echocardiography. The hepatic venous waveform was obtained and classified into 3 types. A variety of HV measurements, including the maximal velocities of the atrial systolic, systolic (S), end ventricular systolic, and diastolic (D) waves and the ratio of the S- and D- wave velocities (S/D ratio), were acquired. TR severity was significantly correlated with the S- ( r = -0.380, p = 0.042) and D- ( r = 0.468, p = 0.011) wave velocities and the S/D ratio ( r = -0.747, p < 0.001). Receiver operating characteristic curve analysis revealed the highest sensitivity and specificity for the S/D ratio (89% and 75%, respectively) at a threshold of 0.97 with excellent accuracy (AUC = 0.911, p < 0.001). In conclusion, PW Doppler ultrasonography of the HV can be used to identify the presence of significant TR and to classify TR severity in dogs.

  11. Clinical, echocardiographic, and Doppler imaging characteristics of mitral valve stenosis in two dogs.

    PubMed

    Fox, P R; Miller, M W; Liu, S K

    1992-11-15

    Mitral stenosis was diagnosed noninvasively by echocardiography and Doppler imaging in 2 Bull Terriers. Two-dimensional echocardiography revealed severe atrial and moderate left ventricular dilatation; severely reduced mitral valve opening excursion; doming of the cranial mitral valve leaflet into the left ventricle during diastole; thickened, nodular cranial mitral valve leaflets; and reduced mitral valve orifice. M-mode echocardiographic findings additionally indicated greatly diminished mitral valve E to F slope and abnormal caudal mitral valve leaflet motion. Color flow Doppler imaging revealed bright bursts of color with aliasing originating from the stenotic mitral valve orifice, extending into the left atrium during systole, and into the left atrium during diastole. Spectral Doppler recordings revealed transvalvular mitral valve gradients and prolonged pressure half-times. Necropsy performed on 1 dog revealed extremely thickened, nodular, and stiff mitral valves with short, thickened, and fused chordae tendineae. The diagnosis of mitral valve stenosis was easily facilitated with diagnostic ultrasonography.

  12. Colour discrimination, colour naming and colour preferences among individuals with Alzheimer's disease.

    PubMed

    Wijk, H; Berg, S; Sivik, L; Steen, B

    1999-12-01

    To study the ability of colour naming, colour discrimination and colour preference in Alzheimer's disease (AD). Descriptive, consecutive sample. Fifty subjects >65 years with AD. Testing colour discrimination, colour naming and colour preferences. Ability to detect colour differences in the yellow, red, blue and green areas, ability to assign a name to 22 colour samples, ability to rank seven colours in order of preference. Discrimination ability was significantly better in the yellow and red area and for lightness variations. Cognitive decline had a significant impact on naming mixed colours and using elaborate colour names. Severity of dementia did not affect the preference rank order of colours. Ability to discriminate is affected in AD, with most errors in the blue and green area. Naming colours shows a cognitive decline. Preferences for colour are stable despite the disease. Copyright 1999 John Wiley & Sons, Ltd.

  13. Covert colour processing in colour agnosia.

    PubMed

    Nijboer, Tanja C W; van Zandvoort, Martine J E; de Haan, Edward H F

    2006-01-01

    Patients with colour agnosia can perceive colours and are able to match coloured patches on hue, but are unable to identify or categorise colours. It is a rare condition and there is as yet no agreement on the clinical definition or a generally accepted explanation. In line with observations from object agnosia and prosopagnosia, we hypothesised that (some of) these patients might still be able to process colour information at an implicit level. In this study, we investigated this possibility of implicit access to colour semantics and colour names in a man (MAH) who suffers from developmental colour agnosia. We designed two experimental computer tasks: an associative colour priming task with a lexical decision response and a reversed Stroop task. The results of these experiments suggest that there is indeed automatic processing of colour, although MAH was unable to explicitly use colour information.

  14. [Contrast enhanced power Doppler and color Doppler ultrasound in breast masses: Efficiency in diagnosis and contributions to differential diagnosis].

    PubMed

    Algül, Ali; Balci, Pinar; Seçil, Mustafa; Canda, Tülay

    2003-06-01

    To compare ability of detection of vascular structures by utilizing ultrasonographic contrast agent (Levovist) prior to and following power Doppler ultrasound (PDUS) and colour Doppler ultrasound (CDUS) and to determine useful parameters in the differentiation of malignant and benign breast masses by means of verified data. Vascularisation characteristics of 38 breast masses (22 malignant, 16 benign) which were confirmed by mammography and B-mode sonography were evaluated by both CDUS and PDUS following and prior to intravenous contrast application. In addition, Vmax and RI values of vascular structures were calculated by Doppler spectral evaluation. Malignant lesions showed more vascularity than benign lesions both with and without contrast enhancement. With both methods, by utilizing contrast agent, central, penetrating and tortuous vascular structures became more significant in malignant lesions when compared with benign lesions. PDUS was able to detect vascular structures better than CDUS; however, the difference was not statistically significant. Presence of peripheral vascularity was not useful in differentiating malignant from benign lesions. Vmax and RI values were higher in malignant lesions and the difference was statistically significant. In both methods, Vmax > 15 cm/sec and RI > 0.80 (CDUS), and RI > 0.70 (PDUS) were accepted as malignancy parameters. Vascular patterns of breast masses as determined with PDUS and CDUS with contrast enhancement and Doppler spectral examinations enabled differentiation of malignant and benign breast lesions. Thus, it is possible to decrease the number of unnecessary surgical interventions.

  15. Refining an Automated Transcranial Doppler System for the Detection of Vasospasm after Traumatic Brain Injury

    DTIC Science & Technology

    2014-09-01

    flow velocity in the MCA and ICA of patients with known vasospasm, as compared to standard TCD run by a trained neurosonographer. Proposed study: Use...the middle cerebral artery (MCA) and internal carotid artery (ICA) of patients with known vasospasm, as compared to standard TCD run by a trained ...Wechsler LR, Toole JF (eds). Transcranial Doppler Ultrasonography. Boston, MA: Butterworth- Heinemann; 1999:109–128. 2. Aaslid R, Nornes H. Musical

  16. Localization of needle tip with color doppler during pericardiocentesis: In vitro validation and initial clinical application

    NASA Technical Reports Server (NTRS)

    Armstrong, G.; Cardon, L.; Vilkomerson, D.; Lipson, D.; Wong, J.; Rodriguez, L. L.; Thomas, J. D.; Griffin, B. P.

    2001-01-01

    This study evaluates a new device that uses color Doppler ultrasonography to enable real-time image guidance of the aspirating needle, which has not been possible until now. The ColorMark device (EchoCath Inc, Princeton, NJ) induces high-frequency, low-amplitude vibrations in the needle to enable localization with color Doppler. We studied this technique in 25 consecutive patients undergoing pericardiocentesis, and in vitro, in a urethane phantom with which the accuracy of color Doppler localization of the needle tip was compared with that obtained by direct measurement. Tip localization was excellent in vitro; errors axial to the ultrasound beam (velocity Doppler -0.13 +/- 0.90 mm, power Doppler -0.05 +/- 1.7 mm) were less than lateral errors (velocity -0.36 +/- 1.8 mm, power -0.02 +/- 2.8 mm). In 18 of 25 patients, the needle was identified and guided into the pericardial space with the ColorMark technique, and it allowed successful, uncomplicated drainage of fluid. Initial failures were the result of incorrect settings on the echocardiographic machine and inappropriate combinations of the needle puncture site and imaging window. This study demonstrates a novel color Doppler technique that is highly accurate at localizing a needle tip. The technique is feasible for guiding pericardiocentesis. Further clinical validation of this technique is required.

  17. Modelling memory colour region for preference colour reproduction

    NASA Astrophysics Data System (ADS)

    Zeng, Huanzhao; Luo, Ronnier

    2010-01-01

    Colour preference adjustment is an essential step for colour image enhancement and perceptual gamut mapping. In colour reproduction for pictorial images, properly shifting colours away from their colorimetric originals may produce more preferred colour reproduction result. Memory colours, as a portion of the colour regions for colour preference adjustment, are especially important for preference colour reproduction. Identifying memory colours or modelling the memory colour region is a basic step to study preferred memory colour enhancement. In this study, we first created gamut for each memory colour region represented as a convex hull, and then used the convex hull to guide mathematical modelling to formulate the colour region for colour enhancement.

  18. Advances in diagnostic ultrasonography.

    PubMed

    Reef, V B

    1991-08-01

    A wide variety of ultrasonographic equipment currently is available for use in equine practice, but no one machine is optimal for every type of imaging. Image quality is the most important factor in equipment selection once the needs of the practitioner are ascertained. The transducer frequencies available, transducer footprints, depth of field displayed, frame rate, gray scale, simultaneous electrocardiography, Doppler, and functions to modify the image are all important considerations. The ability to make measurements off of videocassette recorder playback and future upgradability should be evaluated. Linear array and sector technology are the backbone of equine ultrasonography today. Linear array technology is most useful for a high-volume broodmare practice, whereas sector technology is ideal for a more general equine practice. The curved or convex linear scanner has more applications than the standard linear array and is equipped with the linear array rectal probe, which provides the equine practitioner with a more versatile unit for equine ultrasonographic evaluations. The annular array and phased array systems have improved image quality, but each has its own limitations. The new sector scanners still provide the most versatile affordable equipment for equine general practice.

  19. Is there a relation between priapism occurring after penile doppler ultrasonography and international erectile function index score and erection hardness score levels?

    PubMed Central

    Sönmez, Mehmet Giray; Öztürk, Ahmet

    2017-01-01

    Objective The relation between Erection Hardness Score (EHS) and The International Erectile Function Index (IIEF) Questionnaire- Erectile Function Domain Score (IIEF-EF score) used in erectile dysfunction (ED) evaluation and the prevalence of priapism after penile Doppler ultrasonography (PDU) was examined in this study. Material and methods A total of 62 patients who had PDU were included in the study. Patients were divided into two groups; there were 33 patients in IIEF-EF score ≤10, EHS <2 group (Group 1) and 29 patients in IIEF-EF score >10, EHS ≥2 group (Group 2). The two groups separated according to their scores were compared for age, body mass index (BMI), prevalence of priapism, vascular comorbidities and duration of erection. Results When compared to Group 2, median age, rate of vascular comorbidities rate and BMI were detected to be higher in Group 1 with IIEF-EF score ≤10 and EHS <2. But contrary to age and rate of vascular comorbidities (p=0.035, p=0.049 respectively), higher BMI was detected to be statistically insignificant (p=0.093). Duration of erection, IIEF-EF score and number of cases with priapism were significantly higher in Group 2 with IIEF-EF score >10 and EHS ≥2 (p<0.001, p=0.027, p=0.049 respectively). Conclusion High IIEF-EF and EHS scores, younger ages and lower rates of vascular comorbidities in patients from whom PDU was demanded increase the prevalence of priapism. PMID:29201505

  20. Is there a relation between priapism occurring after penile doppler ultrasonography and international erectile function index score and erection hardness score levels?

    PubMed

    Sönmez, Mehmet Giray; Öztürk, Ahmet

    2017-12-01

    The relation between Erection Hardness Score (EHS) and The International Erectile Function Index (IIEF) Questionnaire- Erectile Function Domain Score (IIEF-EF score) used in erectile dysfunction (ED) evaluation and the prevalence of priapism after penile Doppler ultrasonography (PDU) was examined in this study. A total of 62 patients who had PDU were included in the study. Patients were divided into two groups; there were 33 patients in IIEF-EF score ≤10, EHS <2 group (Group 1) and 29 patients in IIEF-EF score >10, EHS ≥2 group (Group 2). The two groups separated according to their scores were compared for age, body mass index (BMI), prevalence of priapism, vascular comorbidities and duration of erection. When compared to Group 2, median age, rate of vascular comorbidities rate and BMI were detected to be higher in Group 1 with IIEF-EF score ≤10 and EHS <2. But contrary to age and rate of vascular comorbidities (p=0.035, p=0.049 respectively), higher BMI was detected to be statistically insignificant (p=0.093). Duration of erection, IIEF-EF score and number of cases with priapism were significantly higher in Group 2 with IIEF-EF score >10 and EHS ≥2 (p<0.001, p=0.027, p=0.049 respectively). High IIEF-EF and EHS scores, younger ages and lower rates of vascular comorbidities in patients from whom PDU was demanded increase the prevalence of priapism.

  1. Memory colours affect colour appearance.

    PubMed

    Witzel, Christoph; Olkkonen, Maria; Gegenfurtner, Karl R

    2016-01-01

    Memory colour effects show that colour perception is affected by memory and prior knowledge and hence by cognition. None of Firestone & Scholl's (F&S's) potential pitfalls apply to our work on memory colours. We present a Bayesian model of colour appearance to illustrate that an interaction between perception and memory is plausible from the perspective of vision science.

  2. Is Routine Intraoperative Contrast-Enhanced Ultrasonography Useful During Whole Liver Transplantation?

    PubMed

    Golse, Nicolas; Santoni, Simone; Karam, Vincent; Ciacio, Oriana; Pittau, Gabriella; Allard, Marc-Antoine; Cherqui, Daniel; Sa Cunha, Antonio; Adam, René; Castaing, Denis; Vibert, Eric

    2018-05-01

    Vascular complications following liver transplantation (LT) may result from technical deficiencies. Intraoperative diagnosis remains challenging but can prevent serious delayed complications. Intraoperative Doppler ultrasonography (IOUS) represents the gold standard for imaging, although it requires radiological skills. Contrast-enhanced ultrasonography has been reported during postoperative assessments, but never intraoperatively (CE-IOUS). The aim of this study was to assess the feasibility of routine CE-IOUS, to evaluate its impact on surgical strategy and its usefulness. All 553 whole LTs performed in our tertiary centre between 01/2010 and 12/2014 were reviewed. We compared perioperative outcomes and long-term survival in IOUS (n = 370) versus CE-IOUS (n = 103) groups. Secondarily, the seven cases where the two imaging findings conflicted (CE+ Group) were matched 1:2 and compared with an exclusively IOUS procedure (CE- Group, n = 14) to assess the consequences of a specific CE-guided strategy. CE-IOUS assessments were successful in 100% of cases, without any adverse effects. Vascular complications and patient/graft survival rates were identical in the IOUS and CE-IOUS groups (p = 0.65, 0.95 and 0.86, respectively). CE-IOUS confirmed IOUS findings in 93% of cases (n = 96) and led to the realization of an additional procedure (median arcuate ligament lysis) and six conservative strategies despite poor arterial (n = 5) or venous flow (n = 1) under Doppler analysis. The CE+ and CE- groups presented statistically identical perioperative and long-term outcomes. This study demonstrated the feasibility of CE-IOUS during whole LT. However, we failed to demonstrate any advantages of CE-IOUS over IOUS. Therefore, IOUS currently remains the gold-standard imaging technique for the intraoperative assessment of vascular patency.

  3. Contrast-enhanced endoscopic ultrasonography: advance and current status

    PubMed Central

    2014-01-01

    Endoscopic ultrasonography (EUS) technology has undergone a great deal of progress along with the color and power Doppler imaging, three-dimensional imaging, electronic scanning, tissue harmonic imaging, and elastography, and one of the most important developments is the ability to acquire contrast-enhanced images. The blood flow in small vessels and the parenchymal microvasculature of the target lesion can be observed non-invasively by contrast-enhanced EUS (CE-EUS). Through a hemodynamic analysis, CE-EUS permits the diagnosis of various gastrointestinal diseases and differential diagnoses between benign and malignant tumors. Recently, mechanical innovations and the development of contrast agents have increased the use of CE-EUS in the diagnostic field, as well as for the assessment of the efficacy of therapeutic agents. The advances in and the current status of CE-EUS are discussed in this review. PMID:25038805

  4. Cerebral hyperperfusion following carotid endarterectomy: diagnostic utility of intraoperative transcranial Doppler ultrasonography compared with single-photon emission computed tomography study.

    PubMed

    Ogasawara, Kuniaki; Inoue, Takashi; Kobayashi, Masakazu; Endo, Hidehoko; Yoshida, Kenji; Fukuda, Takeshi; Terasaki, Kazunori; Ogawa, Akira

    2005-02-01

    Cerebral hyperperfusion syndrome is a rare but serious complication of carotid endarterectomy (CEA). The aim of the present study was to determine whether intraoperative blood flow velocity (BFV) monitoring in the middle cerebral artery (MCA) by using transcranial Doppler ultrasonography (TCD) could be used as a reliable technique to detect cerebral hyperperfusion following CEA by comparing findings with those of brain single photon emission CT (SPECT). Intraoperative BFV monitoring was attempted in 67 patients undergoing CEA for treatment of ipsilateral internal carotid artery (ICA) stenosis (> or =70%). Cerebral blood flow (CBF) was also assessed using SPECT, which was performed before and immediately after CEA. Intraoperative BFV monitoring was achieved in 60 patients. Of the 60 patients, post-CEA hyperperfusion (CBF increase > or =100%, compared with preoperative values) was observed in six patients. The sensitivity, specificity, and positive predictive value of the BFV increases immediately after declamping of the ICA for detecting post-CEA hyperperfusion was 100%, 94% and 67%, respectively, with a cut-off point 2.0-fold that of preclamping BFV. The sensitivity and specificity of the BFV increases at the end of the procedure for detecting post-CEA hyperperfusion were 100% for both parameters, with cut-off points of 2.0- to 2.2-fold BFV of preclamping value. Hyperperfusion syndrome developed in two patients with post-CEA hyperperfusion, but intracerebral hemorrhage did not occur. In one of these two patients, BFV monitoring was not possible because of failure to obtain an adequate bone window. Intraoperative MCA BFV monitoring by using TCD is a less reliable method to detect cerebral hyperperfusion following CEA than postoperative MCA BFV monitoring, provided adequate monitoring can be achieved.

  5. Anatomy and ultrasonography of the normal kidney in brown lemurs: Eulemur fulvus.

    PubMed

    Raharison, Fidiniaina; Mogicato, Giovanni; Sautet, Jean

    2009-08-01

    The purpose of this study is to describe the anatomy and obtain echographic measurements of normal kidneys in brown lemurs (Eulemur fulvus). The anatomical findings show that brown lemur kidneys are comparable to those of rats except for an elongated papilla. The kidneys of 16 (7 females and 9 males) lemurs were examined with two-dimensional and power Doppler ultrasonography under general anesthesia. Morphometrically, the left and right kidney surface areas are comparable (3.29 and 3.51 cm(2)). Kidney area has a significant linear correlation with body weight. Echo-Doppler findings show that the mean renal arterial blood flow speeds for the left and right kidneys are comparable (0.70 and 0.73 m/s). However, flow speed is higher in the male (0.79 m/s) than in the female (0.60 m/s). The renal arterial diameters are between 1.0 and 1.8 mm. The fact that anesthesia can have hemodynamic effects on renal vasculature should be taken into consideration when assessing these echographic results.

  6. Reliability of assessment of upper trapezius morphology, its mechanical properties and blood flow in female patients with myofascial pain syndrome using ultrasonography.

    PubMed

    Adigozali, Hakimeh; Shadmehr, Azadeh; Ebrahimi, Esmail; Rezasoltani, Asghar; Naderi, Farrokh

    2017-01-01

    In the present study, the intra-rater reliability of upper trapezius morphology, its mechanical properties and intramuscular blood circulation in females with myofascial pain syndrome were assessed using ultrasonography. A total of 37 patients (31.05 ± 10 years old) participated in this study. Ultrasonography producer was set up in three stages: a) Gray-scale: to measure muscle thickness, size and area of trigger points; b) Ultrasound elastography: to measure muscle stiffness; and c) Doppler imaging: to assess blood flow indices. According to data analysis, all variables, except End Diastolic Velocity (EDV), had excellent reliability (>0.806). Intra-class Correlation Coefficient (ICC) for EDV was 0.738, which was considered a poor to good reliability. The results of this study introduced a reliable method for developing details of upper trapezius features using muscular ultrasonography in female patients. These variables could be used for objective examination and provide guidelines for treatment plans in clinical settings. Copyright © 2016 Elsevier Ltd. All rights reserved.

  7. The colour preference control based on two-colour combinations

    NASA Astrophysics Data System (ADS)

    Hong, Ji Young; Kwak, Youngshin; Park, Du-Sik; Kim, Chang Yeong

    2008-02-01

    This paper proposes a framework of colour preference control to satisfy the consumer's colour related emotion. A colour harmony algorithm based on two-colour combinations is developed for displaying the images with several complementary colour pairs as the relationship of two-colour combination. The colours of pixels belonging to complementary colour areas in HSV colour space are shifted toward the target hue colours and there is no colour change for the other pixels. According to the developed technique, dynamic emotions by the proposed hue conversion can be improved and the controlled output image shows improved colour emotions in the preference of the human viewer. The psychophysical experiments are conducted to investigate the optimal model parameters to produce the most pleasant image to the users in the respect of colour emotions.

  8. Influence of the observer's level of experience on systolic and diastolic arterial blood pressure measurements using Doppler ultrasonography in healthy conscious cats.

    PubMed

    Gouni, Vassiliki; Tissier, Renaud; Misbach, Charlotte; Balouka, David; Bueno, Hanna; Pouchelon, Jean-Louis; Lefebvre, Hervé P; Chetboul, Valérie

    2015-02-01

    The objective of this study was to determine the influence of the observer's level of experience on within- and between-day variability, and the percentage of successful systolic (SAP) and diastolic arterial blood pressure (DAP) measurements obtained by Doppler ultrasonography (DU) in awake cats. For this purpose, six healthy conscious cats were used and four observers with different levels of training performed 144 SAP and DAP measurements on 4 days using DU. Measurements were recorded five consecutive times, and mean values were used for statistical analysis. Only the two most skilled observers - a PhD student in cardiology and a Dipl ECVIM-CA (cardiology) - had within- and between-day coefficients of variation (CVs) for SAP ⩽16% (13-16%). Conversely, the two less experienced observers - a fifth-year student and an assistant - had high between-day CVs (61% and 73%). For DAP, only the most experienced observer (Dipl ECVIM-CA) succeeded in 100% of the attempts, with within- and between-day CVs of 11% and 4%, respectively. Conversely, DAP could not be measured by the other three observers in 8%, 19% and 56% of attempts (from the highest to the lowest level of experience); therefore, the corresponding CV values could not be calculated. In conclusion, SAP may be assessed using DU in healthy awake cats with good repeatability and reproducibility by a well-trained observer. Measurement of DAP is more difficult than of SAP, and needs a longer training period, which represents one of the limitations of DU in cats. © ISFM and AAFP 2014.

  9. A colour image reproduction framework for 3D colour printing

    NASA Astrophysics Data System (ADS)

    Xiao, Kaida; Sohiab, Ali; Sun, Pei-li; Yates, Julian M.; Li, Changjun; Wuerger, Sophie

    2016-10-01

    In this paper, the current technologies in full colour 3D printing technology were introduced. A framework of colour image reproduction process for 3D colour printing is proposed. A special focus was put on colour management for 3D printed objects. Two approaches, colorimetric colour reproduction and spectral based colour reproduction are proposed in order to faithfully reproduce colours in 3D objects. Two key studies, colour reproduction for soft tissue prostheses and colour uniformity correction across different orientations are described subsequently. Results are clear shown that applying proposed colour image reproduction framework, performance of colour reproduction can be significantly enhanced. With post colour corrections, a further improvement in colour process are achieved for 3D printed objects.

  10. Does colour preference have a role in colour term acquisition?

    PubMed

    Pitchford, Nicola J; Davis, Emma E; Scerif, Gaia

    2009-11-01

    A developmental association exists between colour preference and emerging colour term acquisition in young children. Colour preference might influence colour term acquisition by directing attention towards or away from a particular colour, making it more or less memorable. To investigate the role that colour preference may have in the acquisition of colour terms, experimental tasks of colour preference, discrimination, attention, memory, and new colour term learning, were given to three groups of participants (preschool children; primary school children; and adults). Each task utilized the same colour stimuli, which were four computer-simulated colours, matched perceptually to four different Munsell chips, drawn from the same colour category. Three colours varied systematically from an anchor colour (10PB 4/8) only in saturation (10PB 4/4), luminance (10PB 6/8), or hue (5P 4/8). Results showed that within-category colour preferences emerged with age, and that when established within individuals, most preferred colours were named significantly more accurately than least preferred colours, although this association did not appear to be mediated directly by attention or memory. Rather, perceptual saliency was shown to have a mediating role, to some extent, in determining the relationship between colour preference and the cognitive processing of colour.

  11. Colour Terms Affect Detection of Colour and Colour-Associated Objects Suppressed from Visual Awareness

    PubMed Central

    Forder, Lewis; Taylor, Olivia; Mankin, Helen; Scott, Ryan B.; Franklin, Anna

    2016-01-01

    The idea that language can affect how we see the world continues to create controversy. A potentially important study in this field has shown that when an object is suppressed from visual awareness using continuous flash suppression (a form of binocular rivalry), detection of the object is differently affected by a preceding word prime depending on whether the prime matches or does not match the object. This may suggest that language can affect early stages of vision. We replicated this paradigm and further investigated whether colour terms likewise influence the detection of colours or colour-associated object images suppressed from visual awareness by continuous flash suppression. This method presents rapidly changing visual noise to one eye while the target stimulus is presented to the other. It has been shown to delay conscious perception of a target for up to several minutes. In Experiment 1 we presented greyscale photos of objects. They were either preceded by a congruent object label, an incongruent label, or white noise. Detection sensitivity (d’) and hit rates were significantly poorer for suppressed objects preceded by an incongruent label compared to a congruent label or noise. In Experiment 2, targets were coloured discs preceded by a colour term. Detection sensitivity was significantly worse for suppressed colour patches preceded by an incongruent colour term as compared to a congruent term or white noise. In Experiment 3 targets were suppressed greyscale object images preceded by an auditory presentation of a colour term. On congruent trials the colour term matched the object’s stereotypical colour and on incongruent trials the colour term mismatched. Detection sensitivity was significantly poorer on incongruent trials than congruent trials. Overall, these findings suggest that colour terms affect awareness of coloured stimuli and colour- associated objects, and provide new evidence for language-perception interaction in the brain. PMID:27023274

  12. Colour Terms Affect Detection of Colour and Colour-Associated Objects Suppressed from Visual Awareness.

    PubMed

    Forder, Lewis; Taylor, Olivia; Mankin, Helen; Scott, Ryan B; Franklin, Anna

    2016-01-01

    The idea that language can affect how we see the world continues to create controversy. A potentially important study in this field has shown that when an object is suppressed from visual awareness using continuous flash suppression (a form of binocular rivalry), detection of the object is differently affected by a preceding word prime depending on whether the prime matches or does not match the object. This may suggest that language can affect early stages of vision. We replicated this paradigm and further investigated whether colour terms likewise influence the detection of colours or colour-associated object images suppressed from visual awareness by continuous flash suppression. This method presents rapidly changing visual noise to one eye while the target stimulus is presented to the other. It has been shown to delay conscious perception of a target for up to several minutes. In Experiment 1 we presented greyscale photos of objects. They were either preceded by a congruent object label, an incongruent label, or white noise. Detection sensitivity (d') and hit rates were significantly poorer for suppressed objects preceded by an incongruent label compared to a congruent label or noise. In Experiment 2, targets were coloured discs preceded by a colour term. Detection sensitivity was significantly worse for suppressed colour patches preceded by an incongruent colour term as compared to a congruent term or white noise. In Experiment 3 targets were suppressed greyscale object images preceded by an auditory presentation of a colour term. On congruent trials the colour term matched the object's stereotypical colour and on incongruent trials the colour term mismatched. Detection sensitivity was significantly poorer on incongruent trials than congruent trials. Overall, these findings suggest that colour terms affect awareness of coloured stimuli and colour- associated objects, and provide new evidence for language-perception interaction in the brain.

  13. Investigation of mammary blood flow changes by transrectal colour Doppler sonography in an Escherichia coli mastitis model.

    PubMed

    Potapow, André; Sauter-Louis, Carola; Schmauder, Sandra; Friker, Jutta; Nautrup, Cordula Poulsen; Mehne, Daniel; Petzl, Wolfram; Zerbe, Holm

    2010-05-01

    The objectives of this preliminary investigation were to evaluate the feasibility of transrectal colour Doppler sonography (TCDS) for determining blood flow of the pudendoepigastric trunk in cows with experimentally induced Escherichia coli Mastitis. Five primiparous Holstein dairy cows, 4-6 months after calving, were examined in two trials. All monitored udder quarters were initially clinically healthy, somatic cell count (SCC) was <50 000 cells/ml and bacteriologically negative. The blood flow of the left and the right pudendoepigastric trunk was described by the blood flow volume (BFV). In the methodological part of the study, the intra-observer precision of the method was evaluated. The coefficients of variation of the BFV were 7.1% for the left and 9.4% for the right pudendoepigastric trunk. The intraclass correlation coefficients of the BFV were 0.99 (P<0.001) for the left and 0.75 (P=0.004) for the right vessel. BFV did not differ significantly between the left and the right side nor between pre- and post-milking nor between oestrus and dioestrus. In the experimental part of the study, significant differences of increasing BFV between 0 and 12 h p.i. (post infectionem) (P=0.043) and decreasing BFV between 12 and 24 h p.i. (P=0.043) were discovered for the pudendoepigastric trunk of the infected right side. In the left-right (control-infection) comparison a significant increase of the right BFV was observed at 12 h p.i. (P=0.043). The difference of an increasing SCC correlated positively with the difference of an increasing BFV between 0 and 12 h p.i. (Spearman's rho=1.00; P=0.043) for the right infected side. It was shown that TCDS is a reproducible technique for investigating pathological mammary blood flow changes at an early stage of acute mastitis.

  14. Ultrasonography of the biliary tract - up to date. The importance of correlation between imaging methods and patients' signs and symptoms.

    PubMed

    Badea, Radu; Zaro, Răzvan; Tanțău, Marcel; Chiorean, Liliana

    2015-09-01

    Ultrasonography is generally accepted and performed as a first choice imaging technique in patients with jaundice. The method allows the discrimination between cholestatic and mechanical jaundice. The existing procedures are multiple: gray scale, Doppler, i.v. contrast enhancement, elastography, tridimensional ultrasonography, each of these with different contribution to the positive and differential diagnosis regarding the nature of the jaundice. The final diagnosis is a multimodal one and the efficiency is dependent on the level of the available technology, the examiner's experience, the degree and modality of integration of the data within the clinical context, as well as on the portfolio of available imaging procedures. This review shows the main ultrasonographic methods consecrated in the evaluation of the biliary tree. It also underlines the integrated character of the procedures, as well as the necessity to correlate with other imaging methods and the clinical situation.

  15. Non-invasive Monitoring of Intracranial Pressure Using Transcranial Doppler Ultrasonography: Is It Possible?

    PubMed

    Cardim, Danilo; Robba, C; Bohdanowicz, M; Donnelly, J; Cabella, B; Liu, X; Cabeleira, M; Smielewski, P; Schmidt, B; Czosnyka, M

    2016-12-01

    Although intracranial pressure (ICP) is essential to guide management of patients suffering from acute brain diseases, this signal is often neglected outside the neurocritical care environment. This is mainly attributed to the intrinsic risks of the available invasive techniques, which have prevented ICP monitoring in many conditions affecting the intracranial homeostasis, from mild traumatic brain injury to liver encephalopathy. In such scenario, methods for non-invasive monitoring of ICP (nICP) could improve clinical management of these conditions. A review of the literature was performed on PUBMED using the search keywords 'Transcranial Doppler non-invasive intracranial pressure.' Transcranial Doppler (TCD) is a technique primarily aimed at assessing the cerebrovascular dynamics through the cerebral blood flow velocity (FV). Its applicability for nICP assessment emerged from observation that some TCD-derived parameters change during increase of ICP, such as the shape of FV pulse waveform or pulsatility index. Methods were grouped as: based on TCD pulsatility index; aimed at non-invasive estimation of cerebral perfusion pressure and model-based methods. Published studies present with different accuracies, with prediction abilities (AUCs) for detection of ICP ≥20 mmHg ranging from 0.62 to 0.92. This discrepancy could result from inconsistent assessment measures and application in different conditions, from traumatic brain injury to hydrocephalus and stroke. Most of the reports stress a potential advantage of TCD as it provides the possibility to monitor changes of ICP in time. Overall accuracy for TCD-based methods ranges around ±12 mmHg, with a great potential of tracing dynamical changes of ICP in time, particularly those of vasogenic nature.

  16. Contrast-enhanced endoscopic ultrasonography in digestive diseases.

    PubMed

    Hirooka, Yoshiki; Itoh, Akihiro; Kawashima, Hiroki; Ohno, Eizaburo; Itoh, Yuya; Nakamura, Yosuke; Hiramatsu, Takeshi; Sugimoto, Hiroyuki; Sumi, Hajime; Hayashi, Daijiro; Ohmiya, Naoki; Miyahara, Ryoji; Nakamura, Masanao; Funasaka, Kohei; Ishigami, Masatoshi; Katano, Yoshiaki; Goto, Hidemi

    2012-10-01

    Contrast-enhanced endoscopic ultrasonography (CE-EUS) was introduced in the early 1990s. The concept of the injection of carbon dioxide microbubbles into the hepatic artery as a contrast material (enhanced ultrasonography) led to "endoscopic ultrasonographic angiography". After the arrival of the first-generation contrast agent, high-frequency (12 MHz) EUS brought about the enhancement of EUS images in the diagnosis of pancreatico-biliary diseases, upper gastrointestinal (GI) cancer, and submucosal tumors. The electronic scanning endosonoscope with both radial and linear probes enabled the use of high-end ultrasound machines and depicted the enhancement of both color/power Doppler flow-based imaging and harmonic-based imaging using second-generation contrast agents. Many reports have described the usefulness of the differential diagnosis of pancreatic diseases and other abdominal lesions. Quantitative evaluation of CE-EUS images was an objective method of diagnosis using the time-intensity curve (TIC), but it was limited to the region of interest. Recently developed Inflow Time Mapping™ can be generated from stored clips and used to display the pattern of signal enhancement with time after injection, offering temporal difference of contrast agents and improved tumor characterization. On the other hand, three-dimensional CE-EUS images added new information to the literature, but lacked positional information. Three-dimensional CE-EUS with accurate positional information is awaited. To date, most reports have been related to pancreatic lesions or lymph nodes. Hemodynamic analysis might be of use for diseases in other organs: upper GI cancer diagnosis, submucosal tumors, and biliary disorders, and it might also provide functional information. Studies of CE-EUS in diseases in many other organs will increase in the near future.

  17. Colour detection thresholds in faces and colour patches.

    PubMed

    Tan, Kok Wei; Stephen, Ian D

    2013-01-01

    Human facial skin colour reflects individuals' underlying health (Stephen et al 2011 Evolution & Human Behavior 32 216-227); and enhanced facial skin CIELab b* (yellowness), a* (redness), and L* (lightness) are perceived as healthy (also Stephen et al 2009a International Journal of Primatology 30 845-857). Here, we examine Malaysian Chinese participants' detection thresholds for CIELab L* (lightness), a* (redness), and b* (yellowness) colour changes in Asian, African, and Caucasian faces and skin coloured patches. Twelve face photos and three skin coloured patches were transformed to produce four pairs of images of each individual face and colour patch with different amounts of red, yellow, or lightness, from very subtle (deltaE = 1.2) to quite large differences (deltaE = 9.6). Participants were asked to decide which of sequentially displayed, paired same-face images or colour patches were lighter, redder, or yellower. Changes in facial redness, followed by changes in yellowness, were more easily discriminated than changes in luminance. However, visual sensitivity was not greater for redness and yellowness in nonface stimuli, suggesting red facial skin colour special salience. Participants were also significantly better at recognizing colour differences in own-race (Asian) and Caucasian faces than in African faces, suggesting the existence of cross-race effect in discriminating facial colours. Humans' colour vision may have been selected for skin colour signalling (Changizi et al 2006 Biology Letters 2 217-221), enabling individuals to perceive subtle changes in skin colour, reflecting health and emotional status.

  18. Correlation between ocular pulse amplitude measured by dynamic contour tonometer and colour Doppler flow imaging of the arteric retrobulbar vessels.

    PubMed

    Marjanović, Ivan; Mijajlović, Milija; Covicković-Sternić, Nadezda; Kontić, Djordje; Hentova-Senćanić, Paraskeva; Marković, Vujica; Bozić, Marija

    2011-01-01

    An altered perfusion of the optic nerve head has been proposed as a pathogenic factor in glaucoma. The aim of this study was to evaluate the correlation between ocular pulse amplitude (OPA), measured by Dynamic contour tonometer (DCT) and colour Doppler imaging (CDI) of the arteric retrobulbar vessels. Twenty patients older than 50 years were examined, and divided into two equal groups. The first group comprised of patients with normal tension glaucoma treated with topical antiglaucomatous therapy, and the second group included patients with ocular hypertension and glaucoma suspicious without any antiglaucomatous therapy. Ocular pulse amplitude (OPA) was measured with DCT. CDI was also performed. We measured haemodynamic parameters of the internal carotid artery (ICA), ophthalmic artery (OA), central retinal artery (CRA), and posterior ciliary arteries (PCA). Peak systolic (PSV), end-diastolic (EDV) velocities were measured, and resistance index (RI) and pulsatility index (PI) were calculated. Correlation with OPA showed indirect servitude in the RI of the ICA, RI and PI of the CRA, in the first group; and in the PSV and EDV of the ICA, in the RI and PI of the OA, EDV and RI of the CRA, and RI of the PCA, in the second group Increase of OPA was mostly followed by the increase of the parameters (PSV, EDV, RI, and PI) of the arteric retrobulbar vessels in the first group; in the second group, increase of OPA was in almost 50% of parameters followed by their decrease.

  19. Hue-specific colour memory impairment in an individual with intact colour perception and colour naming.

    PubMed

    Jakobson, L S; Pearson, P M; Robertson, B

    2008-01-15

    Cases of hue-selective dyschomatopsias, together with the results of recent optical imaging studies [Xiao, Y., Casti, A. R. R., Xiao, J., & Kaplan, E. (2006). A spatially organized representation of colour in macaque primary visual cortex. Perception, 35, ECVP Abstract Supplement; Xiao, Y., Wang, Y., & Felleman, D. J. (2003). A spatially organized representation of colour in macaque cortical area V2. Nature, 421, 535-539], have provided support for the idea that different colours are processed in spatially distinct regions of extrastriate cortex. In the present report, we provide evidence suggesting that a similar, but distinct, map may exist for representations of colour in memory. This evidence comes from observations of a young woman (QP) who demonstrates an isolated deficit in colour memory secondary to a concussive episode. Despite having normal colour perception and colour naming skills, and above-average memory skills in other domains, QP's ability to recall visually encoded colour information over short retention intervals is dramatically impaired. Her long-term memory for colour and her colour imagery skills are also abnormal. Surprisingly, however, these impairments are not seen with all hues; specifically, her ability to remember or imagine blue shades is spared. This interesting case contributes to the literature suggesting that colour perception, naming, and memory can be clinically dissociated, and provides insights into the organization of colour information in memory.

  20. Colour Coding of Maps for Colour Deficient Observers.

    PubMed

    Røise, Anne Kari; Kvitle, Anne Kristin; Green, Phil

    2016-01-01

    We evaluate the colour coding of a web map traffic information service based on profiles simulating colour vision deficiencies. Based on these simulations and principles for universal design, we propose adjustments of the existing colours creating more readable maps for the colour vision deficient observers.

  1. Colour preferences and colour vision in poultry chicks.

    PubMed

    Ham, A D; Osorio, D

    2007-08-22

    The dramatic colours of biological communication signals raise questions about how animals perceive suprathreshold colour differences, and there are long-standing questions about colour preferences and colour categorization by non-human species. This study investigates preferences of foraging poultry chicks (Gallus gallus) as they peck at coloured objects. Work on colour recognition often deals with responses to monochromatic lights and how animals divide the spectrum. We used complementary colours, where the intermediate is grey, and related the chicks' choices to three models of the factors that may affect the attractiveness. Two models assume that attractiveness is determined by a metric based on the colour discrimination threshold either (i) by chromatic contrast against the background or (ii) relative to an internal standard. An alternative third model is that categorization is important. We tested newly hatched and 9-day-old chicks with four pairs of (avian) complementary colours, which were orange, blue, red and green for humans. Chromatic contrast was more relevant to newly hatched chicks than to 9-day-old birds, but in neither case could contrast alone account for preferences; especially for orange over blue. For older chicks, there is evidence for categorization of complementary colours, with a boundary at grey.

  2. Colour in flux: describing and printing colour in art

    NASA Astrophysics Data System (ADS)

    Parraman, Carinna

    2008-01-01

    This presentation will describe artists, practitioners and scientists, who were interested in developing a deeper psychological, emotional and practical understanding of the human visual system who were working with wavelength, paint and other materials. From a selection of prints at The Prints and Drawings Department at Tate London, the presentation will refer to artists who were motivated by issues relating to how colour pigment was mixed and printed, to interrogate and explain colour perception and colour science, and in art, how artists have used colour to challenge the viewer and how a viewer might describe their experience of colour. The title Colour in Flux refers, not only to the perceptual effect of the juxtaposition of one colour pigment with another, but also to the changes and challenges for the print industry. In the light of screenprinted examples from the 60s and 70s, the presentation will discuss 21 st century ideas on colour and how these notions have informed the Centre for Fine Print Research's (CFPR) practical research in colour printing. The latter part of this presentation will discuss the implications for the need to change methods in mixing inks that moves away from existing colour spaces, from non intuitive colour mixing to bespoke ink sets, colour mixing approaches and colour mixing methods that are not reliant on RGB or CMYK.

  3. Digital colour management system for colour parameters reconstruction

    NASA Astrophysics Data System (ADS)

    Grudzinski, Karol; Lasmanowicz, Piotr; Assis, Lucas M. N.; Pawlicka, Agnieszka; Januszko, Adam

    2013-10-01

    Digital Colour Management System (DCMS) and its application to new adaptive camouflage system are presented in this paper. The DCMS is a digital colour rendering method which would allow for transformation of a real image into a set of colour pixels displayed on a computer monitor. Consequently, it can analyse pixels' colour which comprise images of the environment such as desert, semi-desert, jungle, farmland or rocky mountain in order to prepare an adaptive camouflage pattern most suited for the terrain. This system is described in present work as well as the use the subtractive colours mixing method to construct the real time colour changing electrochromic window/pixel (ECD) for camouflage purpose. The ECD with glass/ITO/Prussian Blue(PB)/electrolyte/CeO2-TiO2/ITO/glass configuration was assembled and characterized. The ECD switched between green and yellow after +/-1.5 V application and the colours have been controlled by Digital Colour Management System and described by CIE LAB parameters.

  4. Does Colour Preference Have a Role in Colour Term Acquisition?

    ERIC Educational Resources Information Center

    Pitchford, Nicola J.; Davis, Emma E.; Scerif, Gaia

    2009-01-01

    A developmental association exists between colour preference and emerging colour term acquisition in young children. Colour preference might influence colour term acquisition by directing attention towards or away from a particular colour, making it more or less memorable. To investigate the role that colour preference may have in the acquisition…

  5. Color Doppler sonography and angioscintigraphy in hepatic Hodgkin’s lymphoma

    PubMed Central

    Stojković, Mirjana V; Artiko, Vera M; Radoman, Irena B; Knežević, Slavko J; Lukić, Snezana M; Kerkez, Mirko D; Lekić, Nebojsa S; Antić, Andrija A; Žuvela, Marinko M; Ranković, Vitomir I; Petrović, Milorad N; Šobić, Dragana P; Obradović, Vladimir B

    2009-01-01

    AIM: To estimate the characteristics of Color Doppler findings and the results of hepatic radionuclide angiography (HRA) in secondary Hodgkin’s hepatic lymphoma. METHODS: The research included patients with a diagnosis of Hodgkin’s lymphoma with metastatic focal lesions in the liver and controls. Morphologic characteristics of focal liver lesions and hemodynamic parameters were examined by pulsed and Color Doppler in the portal, hepatic and splenic veins were examined. Hepatic perfusion index (HPI) estimated by HRA was calculated. RESULTS: In the majority of patients, hepatomegaly was observed. Lesions were mostly hypoechoic and mixed, solitary or multiple. Some of the patients presented with dilated splenic veins and hepatofugal blood flow. A pulse wave was registered in the centre and at the margins of lymphoma. The average velocity of the pulse wave was higher at the margins (P > 0.05). A continuous venous wave was found only at the margins of lymphoma. There was no linear correlation between lymphoma size and velocity of pulse and continuous wave (r = 390, P < 0.01). HPI was significantly lower in patients with lymphomas than in controls (P < 0.05), pointing out increased arterial perfusion in comparison to portal perfusion. CONCLUSION: Color Doppler ultrasonography is a sensitive method for the detection of neovascularization in Hodgkin’s hepatic lymphoma and estimation of its intensity. Hepatic radionuclide angiography can additionally help in the assesment of vascularisation of liver lesions. PMID:19598303

  6. Colours sometimes count: awareness and bidirectionality in grapheme-colour synaesthesia.

    PubMed

    Johnson, Addie; Jepma, Marieke; de Jong, Ritske

    2007-10-01

    Three experiments were conducted with 10 grapheme-colour synaesthetes and 10 matched controls to investigate (a) whether awareness of the inducer grapheme is necessary for synaesthetic colour induction and (b) whether grapheme-colour synaesthesia may be bidirectional in the sense that not only do graphemes induce colours, but that colours influence the processing of graphemes. Using attentional blink and Stroop paradigms with digit targets, we found that some synaesthetes did report "seeing" synaesthetic colours even when they were not able to report the inducing digit. Moreover, congruency effects (effects of matching the colour of digit presentation with the synaesthetic colour associated with that digit) suggested that grapheme-colour synaesthesia can be bidirectional, at least for some synaesthetes.

  7. Transcranial doppler ultrasonography should it be the first choice for persistent foramen ovale screening?

    PubMed Central

    2014-01-01

    Background Persistent foramen ovale (PFO) is considered a cause of cryptogenic stroke and a risk factor for neurological events in young patients. The reference standard for identifying a PFO is contrast-enhanced transesophageal echocardiography (TEE). The goal of this study was to evaluate the feasibility of transcranial color Doppler (TCD) and its diagnostic sensitivity compared with TEE. Methods We investigated 420 patients admitted to our department with cryptogenic stroke, transient ischemic attacks or other neurological symptoms. All patients underwent TCD and TEE evaluation. TCD and TEE examinations were performed according to a standardized procedure: air-mixed saline was injected into the right antecubital vein three times, while the Doppler signal was recorded during the Valsalva maneuver. During TCD the passage of contrast into the right-middle cerebral artery was recorded 25 seconds following the Valsalva maneuver. Results We detected a right-to-left shunt in 220 patients (52.3%) and no-shunts in 159 patients (37.9%) with both TCD and TEE. In 20 (4.8%) patients TEE did not reveal contrast passage which was then detected by TCD. In 21 (5.0%) patients only TEE revealed a PFO. The feasibility of both methods was 100%. TCD had a sensitivity of 95% and a specificity of 92% in the diagnosis of PFO. Conclusions TCD has a relatively good sensitivity and specificity. TCD and TEE are complementary diagnostic tests for PFO, but TCD should be recommended as the first choice for screening because of its simplicity, non-invasive character, low cost and high feasibility. PMID:24884981

  8. False-colour palette generation using a reference colour gamut

    NASA Astrophysics Data System (ADS)

    Green, Phil

    2015-01-01

    Monochrome images are often converted to false-colour images, in which arbitrary colours are assigned to regions of the image to aid recognition of features within the image. Criteria for selection of colour palettes vary according to the application, but may include distinctiveness, extensibility, consistency, preference, meaningfulness and universality. A method for defining a palette from colours on the surface of a reference gamut is described, which ensures that all colours in the palette have the maximum chroma available for the given hue angle in the reference gamut. The palette can be re-targeted to a reproduction medium as needed using colour management, and this method ensures consistency between cross-media colour reproductions using the palette.

  9. Multivariate methods to visualise colour-space and colour discrimination data.

    PubMed

    Hastings, Gareth D; Rubin, Alan

    2015-01-01

    Despite most modern colour spaces treating colour as three-dimensional (3-D), colour data is usually not visualised in 3-D (and two-dimensional (2-D) projection-plane segments and multiple 2-D perspective views are used instead). The objectives of this article are firstly, to introduce a truly 3-D percept of colour space using stereo-pairs, secondly to view colour discrimination data using that platform, and thirdly to apply formal statistics and multivariate methods to analyse the data in 3-D. This is the first demonstration of the software that generated stereo-pairs of RGB colour space, as well as of a new computerised procedure that investigated colour discrimination by measuring colour just noticeable differences (JND). An initial pilot study and thorough investigation of instrument repeatability were performed. Thereafter, to demonstrate the capabilities of the software, five colour-normal and one colour-deficient subject were examined using the JND procedure and multivariate methods of data analysis. Scatter plots of responses were meaningfully examined in 3-D and were useful in evaluating multivariate normality as well as identifying outliers. The extent and direction of the difference between each JND response and the stimulus colour point was calculated and appreciated in 3-D. Ellipsoidal surfaces of constant probability density (distribution ellipsoids) were fitted to response data; the volumes of these ellipsoids appeared useful in differentiating the colour-deficient subject from the colour-normals. Hypothesis tests of variances and covariances showed many statistically significant differences between the results of the colour-deficient subject and those of the colour-normals, while far fewer differences were found when comparing within colour-normals. The 3-D visualisation of colour data using stereo-pairs, as well as the statistics and multivariate methods of analysis employed, were found to be unique and useful tools in the representation and study

  10. Colour image compression by grey to colour conversion

    NASA Astrophysics Data System (ADS)

    Drew, Mark S.; Finlayson, Graham D.; Jindal, Abhilash

    2011-03-01

    Instead of de-correlating image luminance from chrominance, some use has been made of using the correlation between the luminance component of an image and its chromatic components, or the correlation between colour components, for colour image compression. In one approach, the Green colour channel was taken as a base, and the other colour channels or their DCT subbands were approximated as polynomial functions of the base inside image windows. This paper points out that we can do better if we introduce an addressing scheme into the image description such that similar colours are grouped together spatially. With a Luminance component base, we test several colour spaces and rearrangement schemes, including segmentation. and settle on a log-geometric-mean colour space. Along with PSNR versus bits-per-pixel, we found that spatially-keyed s-CIELAB colour error better identifies problem regions. Instead of segmentation, we found that rearranging on sorted chromatic components has almost equal performance and better compression. Here, we sort on each of the chromatic components and separately encode windows of each. The result consists of the original greyscale plane plus the polynomial coefficients of windows of rearranged chromatic values, which are then quantized. The simplicity of the method produces a fast and simple scheme for colour image and video compression, with excellent results.

  11. Rethinking Colour Constancy

    PubMed Central

    Logvinenko, Alexander D.; Funt, Brian; Mirzaei, Hamidreza; Tokunaga, Rumi

    2015-01-01

    Colour constancy needs to be reconsidered in light of the limits imposed by metamer mismatching. Metamer mismatching refers to the fact that two objects reflecting metameric light under one illumination may reflect non-metameric light under a second; so two objects appearing as having the same colour under one illuminant can appear as having different colours under a second. Yet since Helmholtz, object colour has generally been believed to remain relatively constant. The deviations from colour constancy registered in experiments are usually thought to be small enough that they do not contradict the notion of colour constancy. However, it is important to determine how the deviations from colour constancy relate to the limits metamer mismatching imposes on constancy. Hence, we calculated metamer mismatching’s effect for the 20 Munsell papers and 8 pairs of illuminants employed in the colour constancy study by Logvinenko and Tokunaga and found it to be so extensive that the two notions—metamer mismatching and colour constancy—must be mutually exclusive. In particular, the notion of colour constancy leads to some paradoxical phenomena such as the possibility of 20 objects having the same colour under chromatic light dispersing into a hue circle of colours under neutral light. Thus, colour constancy refers to a phenomenon, which because of metamer mismatching, simply cannot exist. Moreover, it obscures the really important visual phenomenon; namely, the alteration of object colours induced by illumination change. We show that colour is not an independent, intrinsic attribute of an object, but rather an attribute of an object/light pair, and then define a concept of material colour in terms of equivalence classes of such object/light pairs. We suggest that studying the shift in material colour under a change in illuminant will be more fruitful than pursuing colour constancy’s false premise that colour is an intrinsic attribute of an object. PMID:26356217

  12. Rethinking Colour Constancy.

    PubMed

    Logvinenko, Alexander D; Funt, Brian; Mirzaei, Hamidreza; Tokunaga, Rumi

    2015-01-01

    Colour constancy needs to be reconsidered in light of the limits imposed by metamer mismatching. Metamer mismatching refers to the fact that two objects reflecting metameric light under one illumination may reflect non-metameric light under a second; so two objects appearing as having the same colour under one illuminant can appear as having different colours under a second. Yet since Helmholtz, object colour has generally been believed to remain relatively constant. The deviations from colour constancy registered in experiments are usually thought to be small enough that they do not contradict the notion of colour constancy. However, it is important to determine how the deviations from colour constancy relate to the limits metamer mismatching imposes on constancy. Hence, we calculated metamer mismatching's effect for the 20 Munsell papers and 8 pairs of illuminants employed in the colour constancy study by Logvinenko and Tokunaga and found it to be so extensive that the two notions-metamer mismatching and colour constancy-must be mutually exclusive. In particular, the notion of colour constancy leads to some paradoxical phenomena such as the possibility of 20 objects having the same colour under chromatic light dispersing into a hue circle of colours under neutral light. Thus, colour constancy refers to a phenomenon, which because of metamer mismatching, simply cannot exist. Moreover, it obscures the really important visual phenomenon; namely, the alteration of object colours induced by illumination change. We show that colour is not an independent, intrinsic attribute of an object, but rather an attribute of an object/light pair, and then define a concept of material colour in terms of equivalence classes of such object/light pairs. We suggest that studying the shift in material colour under a change in illuminant will be more fruitful than pursuing colour constancy's false premise that colour is an intrinsic attribute of an object.

  13. Is salivary gland ultrasonography a useful tool in Sjögren's syndrome? A systematic review.

    PubMed

    Jousse-Joulin, Sandrine; Milic, Vera; Jonsson, Malin V; Plagou, Athena; Theander, Elke; Luciano, Nicoletta; Rachele, Pascale; Baldini, Chiara; Bootsma, Hendrika; Vissink, Arjan; Hocevar, Alojzija; De Vita, Salvatore; Tzioufas, Athanasios G; Alavi, Zarin; Bowman, Simon J; Devauchelle-Pensec, Valerie

    2016-05-01

    Ultrasonography (US) is a sensitive tool in the diagnosis of major salivary gland abnormalities in primary Sjögren's syndrome (pSS). The aim of this systematic review was to assess the metric properties of this technique. PUBMED and EMBASE databases were searched. All publications between January 1988 and January 2013 were considered. Data were extracted from the articles meeting the inclusion criteria according to US definition of salivary gland scoring system and metric properties studied. The type and number of glands tested, study design and metric properties according to OMERACT filter (truth, discrimination, feasibility) were assessed. Of 167 publications identified initially with PUBMED and EMBASE, 31 met the inclusion criteria. The number of pSS patients varied among the studies from 16 to 140. The diagnosis of pSS was in line in most of the cases with the American-European Consensus Group (AECG) classification criteria for Sjögren's syndrome. The US examination was performed in suspected pSS only in studies in which the sensitivity ranged from 45.8 to 91.6% and specificity from 73 to 98.1%. There was heterogeneity in regard to the definition of US in B-mode and few studies used US in colour Doppler. Few studies reported reliability of US and sensitivity to change in pSS. US is a valuable tool for detecting salivary gland abnormalities in pSS. Its reliability has been poorly investigated and there is considerable variation in the definition of US abnormalities. Further studies are required to validate and standardize the US definition of salivary gland in pSS. © The Author 2015. Published by Oxford University Press on behalf of the British Society for Rheumatology. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  14. Assessment of cerebral blood flow with magnetic resonance imaging in children with sickle cell disease: A quantitative comparison with transcranial Doppler ultrasonography.

    PubMed

    Croal, Paula L; Leung, Jackie; Kosinski, Przemyslaw; Shroff, Manohar; Odame, Isaac; Kassner, Andrea

    2017-11-01

    Transcranial Doppler ultrasonography (TCD) is a clinical tool for stratifying ischemic stroke risk by identifying abnormal elevations in blood flow velocity (BFV) in the middle cerebral artery (MCA). However, TCD is not effective at screening for subtle neurologic injury such as silent cerebral infarcts. To better understand this disparity, we compared TCD measures of BFV with tissue-level cerebral blood flow (CBF) using arterial spin-labeling MRI in children with and without sickle cell disease, and correlated these measurements against clinical hematologic measures of disease severity. TCD and MRI assessment were performed in 13 pediatric sickle cell disease patients and eight age-matched controls. Using MRI measures of MCA diameter and territory weight, TCD measures of BFV in the MCA [cm/s] were converted into units of CBF [ml min -1 100 g -1 ] for comparison. There was no significant association between TCD measures of BFV in the MCA and corresponding MRI measures of CBF in patients ( r  =   .28, p  =   .39) or controls ( r  =   .10, p  =   .81). After conversion from BFV into units of CBF, a strong association was observed between TCD and MRI measures ( r  =   .67, p  =   .017 in patients, r  =   .86, p  =   .006 in controls). While BFV in the MCA showed a lack of correlation with arterial oxygen content, an inverse association was observed for CBF measurements. This study demonstrates that BFV in the MCA cannot be used as a surrogate marker for tissue-level CBF in children with sickle cell disease. Therefore, TCD alone may not be sufficient for understanding and predicting subtle pathophysiology in this population, highlighting the potential clinical value of tissue-level CBF.

  15. Developmental colour agnosia.

    PubMed

    van Zandvoort, Martine J E; Nijboer, Tanja C W; de Haan, Edward

    2007-08-01

    Colour agnosia concerns the inability to recognise colours despite intact colour perception, semantic memory for colour information, and colour naming. Patients with selective colour agnosia have been described and the deficit is associated with left hemisphere damage. Here we report a case study of a 43-year-old man who was referred to us with a stroke in his right cerebellar hemisphere. During the standard assessment it transpired that he was unable to name coloured patches. Detailed assessment of his colour processing showed that he suffers from a selective colour agnosia. As he claimed to have had this problem all his life, and the fact that the infratentorial infarct that he had incurred was in an area far away from the brain structures that are known to be involved in colour processing, we suggest that he is the first reported case of developmental colour agnosia.

  16. True and false memory for colour names versus actual colours: support for the visual distinctiveness heuristic in memory for colour information.

    PubMed

    Eslick, Andrea N; Kostic, Bogdan; Cleary, Anne M

    2010-06-01

    In a colour variation of the Deese-Roediger-McDermott (DRM) false memory paradigm, participants studied lists of words critically related to a nonstudied colour name (e.g., "blood, cherry, scarlet, rouge ... "); they later showed false memory for the critical colour name (e.g., "red"). Two additional experiments suggest that participants generate colour imagery in response to such colour-related DRM lists. First, participants claim to experience colour imagery more often following colour-related than standard non-colour-related DRM lists; they also rate their colour imagery as more vivid following colour-related lists. Second, participants exhibit facilitative priming for critical colours in a dot selection task that follows words in the colour-related DRM list, suggesting that colour-related DRM lists prime participants for the actual critical colours themselves. Despite these findings, false memory for critical colour names does not extend to the actual colours themselves (font colours). Rather than leading to source confusion about which colours were self-generated and which were studied, presenting the study lists in varied font colours actually worked to reduce false memory overall. Results are interpreted within the framework of the visual distinctiveness hypothesis.

  17. The value of color Doppler imaging and intralesional steroid injection in pediatric orbital capillary hemangioma.

    PubMed

    Ke, Yifeng; Hao, Rui; He, Yanjin; Tam, Eric S; Li, Xiaorong

    2014-05-01

    To evaluate color Doppler imaging (CDI) as the primary imaging modality in the diagnosis of pediatric orbital capillary hemangioma. This is a retrospective study of 36 consecutive cases of orbital capillary hemangiomas between January 2006 and July 2011. Data on demographic details, clinical findings, gray-scale ultrasonography, CDI characteristics, treatment, and follow-up period were reviewed. The mean age of onset was 7 weeks. Twenty-nine (81%) lesions presented as eyelid masses, whereas seven (19%) presented as exophthalmos. Nineteen (53%) tumors were located on the upper eyelid, seven (19%) on the lower eyelid, six (17%) in the medial canthus, and one on both upper and lower eyelids. Ultrasonography depicted a heterogeneous, well-defined, irregular tumor with a low or moderate echogenicity. All lesions presented with abundant color blood flow on CDI. The intralesional blood flow had a mean peak systolic velocity of 37.5 ± 24.5 cm/second, and a mean resistance index of 0.69 ± 0.16, representing a shift in the pulse Doppler toward high velocity and high resistance. After a single intratumoral injection of betamethasone, 18 cases (50%) resolved. Additionally, 15 (42%) and four (11%) cases resolved after two injections and three injections, respectively. Only three (8%) masses persisted after three injections within the follow-up period. The blood flow characteristics of CDI play a vital role in the differentiation of orbital capillary hemangiomas from other orbital lesions. The availability and lack of adverse effects of CDI enable its utilization in the early clinical diagnosis of pediatric orbital capillary hemangioma. Copyright © 2014. Published by Elsevier B.V.

  18. Evaluation of portal venous velocity with Doppler ultrasound in patients with nonalcoholic fatty liver disease.

    PubMed

    Ulusan, Serife; Yakar, Tolga; Koc, Zafer

    2011-01-01

    We examined the relationship between portal venous velocity and hepatic-abdominal fat in patients with nonalcoholic fatty liver disease (NAFLD), using spectral Doppler ultrasonography (US) and magnetic resonance imaging (MRI). In this prospective study, 35 patients with NAFLD and 29 normal healthy adults (control group) underwent portal Doppler US. The severity of hepatic steatosis in patients with NAFLD was assessed by MRI through chemical shift imaging, using a modification of the Dixon method. Abdominal (intra-abdominal and subcutaneous) fat was measured by MRI. The difference in portal venous velocity between the patients with NAFLD and the control group was significant (p < 0.0001). There was no correlation between the degree of abdominal or hepatic fat and portal venous velocity (p > 0.05). There were strong correlations between the hepatic fat fraction and subcutaneous adiposity (p < 0.0001), intraperitoneal fat accumulation (p = 0.017), and retroperitoneal fat accumulation (p < 0.0001). Our findings suggest that patients with NAFLD have lower portal venous velocities than normal healthy subjects.

  19. Doppler Football

    NASA Astrophysics Data System (ADS)

    Ruiz, Michael J.; Abee, Jeremy

    2006-10-01

    In this paper we present a design for a Doppler football. The classic Doppler ball uses a piezo buzzer and 9-V battery inside a foam ball. In our Doppler football, the sound level is enhanced by directing the 2.8-kHz tone of the buzzer through a hollow cylinder to one end of the football, with an on-off switch placed at the other end. We discuss our device within the historical context of Doppler demonstrations that have evolved over the many decades since Doppler's discovery.

  20. Postoperative ultrasonography of the musculoskeletal system.

    PubMed

    Chun, Kyung Ah; Cho, Kil-Ho

    2015-07-01

    Ultrasonography of the postoperative musculoskeletal system plays an important role in the accurate diagnosis of abnormal lesions in the bone and soft tissues. Ultrasonography is a fast and reliable method with no harmful irradiation for the evaluation of postoperative musculoskeletal complications. In particular, it is not affected by the excessive metal artifacts that appear on computed tomography or magnetic resonance imaging. Another benefit of ultrasonography is its capability to dynamically assess the pathologic movement in joints, muscles, or tendons. This article discusses the frequent applications of musculoskeletal ultrasonography in various postoperative situations including those involving the soft tissues around the metal hardware, arthroplasty, postoperative tendons, recurrent soft tissue tumors, bone unions, and amputation surgery.

  1. [Two- and three-dimensional power Doppler ultrasound in the follow-up of placenta accreta treated conservatively].

    PubMed

    Roulot, A; Barranger, E; Morel, O; Soyer, P; Héquet, D

    2015-02-01

    To determinate the potential of 2D and 3D-ultrasound in the follow-up of patients with placenta accreta treated conservatively. Seven patients with placenta accreta treated conservatively during June 2007 and September 2009 were included. The follow-up consisted in clinical examination and 2D/3D-ultrasound once a month. Criteria studied included clinical outcome, echogenicity at 2D-ultrasound, vascularisation at colour Doppler, Mean Grey at 3D-ultrasound and vascularisation, flow and perfusion index. Seven women with invasive placenta (3 placentas accreta and 2 percreta) were studied. The mean follow-up was 228 days [75-369]. Mean delay for complete elimination of residual placenta was 280 days [120-365]. The two main results were: presence of an increased anechogenicpart in residual placenta before complete resorption for all patients; a systematic and concomitant stop of genital haemorrhage and vascularisation at colour Doppler. High degrees of variability in parameters measured at 3D-ultrasound were observed between patients so that correlations with clinical outcome were found. Long and regular follow-up is essential after conservative management but the role of 3D-ultrasound compared to 2D-ultrasound was not demonstrated in this study. Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  2. Seminal, clinical and colour-Doppler ultrasound correlations of prostatitis-like symptoms in males of infertile couples.

    PubMed

    Lotti, F; Corona, G; Mondaini, N; Maseroli, E; Rossi, M; Filimberti, E; Noci, I; Forti, G; Maggi, M

    2014-01-01

    'Prostatitis-like symptoms' (PLS) are a cluster of bothersome conditions defined as 'perineal and/or ejaculatory pain or discomfort and National Institutes of Health-Chronic Prostatitis Symptom Index (NIH-CPSI) pain subdomain score ≥4' (Nickel's criteria). PLS may originate from the prostate or from other portions of the male genital tract. Although PLS could be associated with 'prostatitis', they should not be confused. The NIH-CPSI is considered the gold-standard for assessing PLS severity. Although previous studies investigated the impact of prostatitis, vesiculitis or epididymitis on semen parameters, correlations between their related symptoms and seminal or scrotal/transrectal colour-Doppler ultrasound (CDU) characteristics have not been carefully determined. And no previous study evaluated the CDU features of PLS in infertile men. This study was aimed at investigating possible associations among NIH-CPSI (total and subdomain) scores and PLS, with seminal, clinical and scrotal/transrectal CDU parameters in a cohort of males of infertile couples. PLS of 400 men (35.8 ± 7.2 years) with a suspected male factor were assessed by the NIH-CPSI. All patients underwent, during the same day, semen analysis, seminal plasma interleukin 8 (sIL-8, a marker of male genital tract inflammation), biochemical evaluation, urine/seminal cultures, scrotal/transrectal CDU. PLS was detected in 39 (9.8%) subjects. After adjusting for age, waist and total testosterone (TT), no association among NIH-CPSI (total or subdomain) scores or PLS and sperm parameters was observed. However, we found a positive association with current positive urine and/or seminal cultures, sIL-8 levels and CDU features suggestive of inflammation of the epididymis, seminal vesicles, prostate, but not of the testis. The aforementioned significant associations of PLS were further confirmed by comparing PLS patients with age-, waist- and TT-matched PLS-free patients (1 : 3 ratio). In conclusion, NIH

  3. Measuring changes in internal meat colour, colour lightness and colour opacity as predictors of cooking time.

    PubMed

    Pakula, Christiane; Stamminger, Rainer

    2012-03-01

    Consumers and cooks often assess the degree of doneness of roasted beef by the internal meat colour. Real-time colour measurement of the cooking process is therefore developed in order to determine the degree of doneness, and thus the end of the cooking process, by the internal meat colour. The colour values (X, Y, Z) provided by the true colour sensor show significant variation within initial values and end values. Change in colour lightness caused by the increase of meat colour opacity is dominant. Calculating the first deviation of the Y values (dY/dt) indicates that most rapid changes in lightness are within a temperature range of 42°C and 56°C. At this temperature, the degree of meat doneness is still assumed to be rare, but it is possible to predict the time needed from this point until the desired degree of doneness is reached. Copyright © 2011 Elsevier Ltd. All rights reserved.

  4. Synaesthesia and colour constancy.

    PubMed

    Erskine, Holly; Mattingley, Jason B; Arnold, Derek H

    2013-04-01

    Grapheme-colour synaesthesia is an atypical condition characterized by the perception of colours when reading achromatic text. We investigated the level of colour processing responsible for these experiences. To do so, we tapped a central characteristic of colour perception. In different lighting conditions the same wavelength of light can prompt the perception of different colours. This helps humans recognize distinctive coloured objects despite changes in illumination. We wanted to see if synaesthetic colours were generated at a neural locus that was susceptible to colour constancy analyses. We used colour matching and naming tasks to examine interactions between simulated coloured illuminants and synaesthetic colours. Neither synaesthetic colour matching or naming was impacted. This contrasted with non-synaesthetic control participants, who performed the colour-matching task with graphemes physically coloured to mimic synaesthesia. Our data suggest that synaesthetic colour signals are not generated at lower-levels of colour processing, but are introduced at higher levels of analysis and are therefore not impacted by the processes responsible for perceptual constancy. Crown Copyright © 2012. Published by Elsevier Ltd. All rights reserved.

  5. [Doppler ultrasonography of the renal artery: Guidelines and predictive factors for the presence of a tight stenosis. Retrospective analysis of 450 consecutive examinations].

    PubMed

    Dejerome, C; Grange, C; De Laforcade, L; Bonin, O; Laville, M; Lermusiaux, P; Long, A

    2018-05-01

    Duplex ultrasonography screening for renal artery stenosis has been the object of guidelines published by four societies designed to optimize the cost-effectiveness of the examination. To determine how well guideline indications for ultrasonography matched with requests and results in our university hospital; to determine whether compliance with guidelines was predictive of renal artery stenosis; to identify guidelines predictive of presence of stenosis; and to determine whether other predictive factors can be recognized. Requests and results of 450 Duplex ultrasonography examinations of the renal arteries performed from January 1st 2014 to December 31st 2015 were compared with published guidelines. At least one guideline indication was identified for 212 of the 450 examinations performed (47.1%). Among these examinations, renal artery stenosis≥70% was identified in 18 patients (8.0%). No case of stenosis was identified during examinations performed outside guideline indications. Factors predictive of stenosis were: compliance with guidelines (OR=21.86 [2.88; 165.8]). Predictive guidelines were: resistant hypertension in spite of appropriate treatment (OR=3.85, [1.44; 10.33], P=0.011), accelerated hypertension (OR=7.30, [1.40; 37.99], P=0.049), sudden unexplained pulmonary edema (OR=7.30, [1.40; 37.99], P=0.049), unexplained renal insufficiency (OR=3.58, [1.37; 9.37], P=0.011), unexplained renal hypotrophy (OR=16.69, [4.38; 63.69], P<0.001), renal asymmetry (OR=4.32, [1.45; 12.85], P<0.016). No other factor was predictive of renal stenosis. These examinations had therapeutic consequences in only 50% of patients. This study confirms the relevance of published guidelines. The diagnostic-effectiveness of Duplex ultrasonography examinations to search for renal artery stenosis depends upon compliance with these guidelines. Copyright © 2018 Elsevier Masson SAS. All rights reserved.

  6. Ultrasonography versus computed tomography for suspected nephrolithiasis.

    PubMed

    Smith-Bindman, Rebecca; Aubin, Chandra; Bailitz, John; Bengiamin, Rimon N; Camargo, Carlos A; Corbo, Jill; Dean, Anthony J; Goldstein, Ruth B; Griffey, Richard T; Jay, Gregory D; Kang, Tarina L; Kriesel, Dana R; Ma, O John; Mallin, Michael; Manson, William; Melnikow, Joy; Miglioretti, Diana L; Miller, Sara K; Mills, Lisa D; Miner, James R; Moghadassi, Michelle; Noble, Vicki E; Press, Gregory M; Stoller, Marshall L; Valencia, Victoria E; Wang, Jessica; Wang, Ralph C; Cummings, Steven R

    2014-09-18

    There is a lack of consensus about whether the initial imaging method for patients with suspected nephrolithiasis should be computed tomography (CT) or ultrasonography. In this multicenter, pragmatic, comparative effectiveness trial, we randomly assigned patients 18 to 76 years of age who presented to the emergency department with suspected nephrolithiasis to undergo initial diagnostic ultrasonography performed by an emergency physician (point-of-care ultrasonography), ultrasonography performed by a radiologist (radiology ultrasonography), or abdominal CT. Subsequent management, including additional imaging, was at the discretion of the physician. We compared the three groups with respect to the 30-day incidence of high-risk diagnoses with complications that could be related to missed or delayed diagnosis and the 6-month cumulative radiation exposure. Secondary outcomes were serious adverse events, related serious adverse events (deemed attributable to study participation), pain (assessed on an 11-point visual-analogue scale, with higher scores indicating more severe pain), return emergency department visits, hospitalizations, and diagnostic accuracy. A total of 2759 patients underwent randomization: 908 to point-of-care ultrasonography, 893 to radiology ultrasonography, and 958 to CT. The incidence of high-risk diagnoses with complications in the first 30 days was low (0.4%) and did not vary according to imaging method. The mean 6-month cumulative radiation exposure was significantly lower in the ultrasonography groups than in the CT group (P<0.001). Serious adverse events occurred in 12.4% of the patients assigned to point-of-care ultrasonography, 10.8% of those assigned to radiology ultrasonography, and 11.2% of those assigned to CT (P=0.50). Related adverse events were infrequent (incidence, 0.4%) and similar across groups. By 7 days, the average pain score was 2.0 in each group (P=0.84). Return emergency department visits, hospitalizations, and diagnostic

  7. Randomized comparison of power Doppler ultrasonography-guided core-needle biopsy with open surgical biopsy for the characterization of lymphadenopathies in patients with suspected lymphoma.

    PubMed

    Pugliese, Novella; Di Perna, M; Cozzolino, I; Ciancia, G; Pettinato, G; Zeppa, P; Varone, V; Masone, S; Cerchione, C; Della Pepa, R; Simeone, L; Giordano, C; Martinelli, V; Salvatore, C; Pane, F; Picardi, M

    2017-04-01

    The sensitivity of lymph node core-needle biopsy under imaging guidance requires validation. We employed power Doppler ultrasonography (PDUS) to select the lymph node most suspected of malignancy and to histologically characterize it through the use of large cutting needle. Institutional review board approval and informed consent were obtained for this randomized clinical trial. In a single center between 1 January 2009 and 31 December 2015, patients with lymph node enlargement suspected for lymphoma were randomly assigned (1:1) to biopsy with either standard surgery or PDUS-guided 16-gauge modified Menghini needle. The primary endpoint was the superiority of sensitivity for the diagnosis of malignancy for core-needle cutting biopsy (CNCB). Secondary endpoints were times to biopsy, complications, and costs. A total of 376 patients were randomized into the two arms and received allocated biopsy. However, four patients undergoing CNCB were excluded for inadequate samples; thus, 372 patients were analyzed. Sensitivity for the detection of malignancy was significantly better for PDUS-guided CNCB [98.8%; 95% confidence interval (CI), 95.9-99.9] than standard biopsy (88.7%; 95% CI, 82.9-93; P < 0.001). For all secondary endpoints, the comparison was significantly disadvantageous for conventional approach. In particular, estimated cost per biopsy performed with standard surgery was 24-fold higher compared with that performed with CNCB. The presence of satellite enlarged reactive and/or necrotic lymph nodes may impair the success of an open surgical biopsy (OSB). PDUS and CNCB with adequate gauge are diagnostic tools that enable effective, safe, fast, and low-cost routine biopsy for patients with suspected lymphoma, avoiding psychological and physical pain of an unnecessary surgical intervention.

  8. Plasmonic colour generation

    NASA Astrophysics Data System (ADS)

    Kristensen, Anders; Yang, Joel K. W.; Bozhevolnyi, Sergey I.; Link, Stephan; Nordlander, Peter; Halas, Naomi J.; Mortensen, N. Asger

    2017-01-01

    Plasmonic colours are structural colours that emerge from resonant interactions between light and metallic nanostructures. The engineering of plasmonic colours is a promising, rapidly emerging research field that could have a large technological impact. We highlight basic properties of plasmonic colours and recent nanofabrication developments, comparing technology-performance indicators for traditional and nanophotonic colour technologies. The structures of interest include diffraction gratings, nanoaperture arrays, thin films, and multilayers and structures that support Mie resonances and whispering-gallery modes. We discuss plasmonic colour nanotechnology based on localized surface plasmon resonances, such as gap plasmons and hybridized disk-hole plasmons, which allow for colour printing with sub-diffraction resolution. We also address a range of fabrication approaches that enable large-area printing and nanoscale lithography compatible with complementary metal-oxide semiconductor technologies, including nanoimprint lithography and self-assembly. Finally, we review recent developments in dynamically reconfigurable plasmonic colours and in the laser-induced post-processing of plasmonic colour surfaces.

  9. Effects of colour on preview search: anticipatory and inhibitory biases for colour.

    PubMed

    Braithwaite, Jason J; Humphreys, Glyn W; Hodsoll, John

    2004-01-01

    Two experiments are reported examining the effects of colour grouping, colour change and target colour foreknowledge under preview search conditions (Watson and Humphreys, 1997). In Experiment 1 we manipulated the colour homogeneity of the old items at initial presentation, and the colour these items subsequently changed into. In all cases participants knew the colour of the target. We found that when the old items changed into the same colour as the new search set, search performance was affected. In Experiment 2 participants did not know the colour of the target. Here we found evidence for a negative colour-based carry-over effect that slowed search for new targets carrying the colour of the old items. This occurred even when the old items changed their original colour and the new target was a singleton. Collectively the results suggest an important role for both colour grouping and colour-based inhibition in the successful rejection of old distractors. The consequence of this, however, is that new stimuli that may carry the critical attribute may take longer to detect. We discuss the results in relation to prior 'feature-blind' accounts of preview effects on visual search.

  10. Characterisation of the n-colour printing process using the spot colour overprint model.

    PubMed

    Deshpande, Kiran; Green, Phil; Pointer, Michael R

    2014-12-29

    This paper is aimed at reproducing the solid spot colours using the n-colour separation. A simplified numerical method, called as the spot colour overprint (SCOP) model, was used for characterising the n-colour printing process. This model was originally developed for estimating the spot colour overprints. It was extended to be used as a generic forward characterisation model for the n-colour printing process. The inverse printer model based on the look-up table was implemented to obtain the colour separation for n-colour printing process. Finally the real-world spot colours were reproduced using 7-colour separation on lithographic offset printing process. The colours printed with 7 inks were compared against the original spot colours to evaluate the accuracy. The results show good accuracy with the mean CIEDE2000 value between the target colours and the printed colours of 2.06. The proposed method can be used successfully to reproduce the spot colours, which can potentially save significant time and cost in the printing and packaging industry.

  11. Quantitative power Doppler ultrasound measures of peripheral joint synovitis in poor prognosis early rheumatoid arthritis predict radiographic progression.

    PubMed

    Sreerangaiah, Dee; Grayer, Michael; Fisher, Benjamin A; Ho, Meilien; Abraham, Sonya; Taylor, Peter C

    2016-01-01

    To assess the value of quantitative vascular imaging by power Doppler US (PDUS) as a tool that can be used to stratify patient risk of joint damage in early seropositive RA while still biologic naive but on synthetic DMARD treatment. Eighty-five patients with seropositive RA of <3 years duration had clinical, laboratory and imaging assessments at 0 and 12 months. Imaging assessments consisted of radiographs of the hands and feet, two-dimensional (2D) high-frequency and PDUS imaging of 10 MCP joints that were scored for erosions and vascularity and three-dimensional (3D) PDUS of MCP joints and wrists that were scored for vascularity. Severe deterioration on radiographs and ultrasonography was seen in 45 and 28% of patients, respectively. The 3D power Doppler volume and 2D vascularity scores were the most useful US predictors of deterioration. These variables were modelled in two equations that estimate structural damage over 12 months. The equations had a sensitivity of 63.2% and specificity of 80.9% for predicting radiographic structural damage and a sensitivity of 54.2% and specificity of 96.7% for predicting structural damage on ultrasonography. In seropositive early RA, quantitative vascular imaging by PDUS has clinical utility in predicting which patients will derive benefit from early use of biologic therapy. © The Author 2015. Published by Oxford University Press on behalf of the British Society for Rheumatology. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  12. Assessment of internal mammary artery and saphenous vein graft patency and flow reserve using transthoracic Doppler echocardiography

    NASA Technical Reports Server (NTRS)

    Chirillo, F.; Bruni, A.; Balestra, G.; Cavallini, C.; Olivari, Z.; Thomas, J. D.; Stritoni, P.

    2001-01-01

    OBJECTIVE: To investigate transthoracic Doppler echocardiography in the identification of coronary artery bypass graft (CABG) flow for assessing graft patency. DESIGN: The initial study group comprised 45 consecutive patients with previous CABG undergoing elective cardiac catheterisation for recurrent ischaemia. The Doppler variables best correlated with angiographic graft patency were then tested prospectively in a further 84 patients (test group). SETTING: Three tertiary referral centres. INTERVENTIONS: Flow velocities in grafts were recorded at rest and during hyperaemia induced by dipyridamole (0.56 mg/kg/4 min), under the guidance of transthoracic colour Doppler flow mapping. Findings on transthoracic Doppler were compared with angiography. MAIN OUTCOME MEASURES: Feasibility of identifying open grafts by Doppler and diagnostic accuracy for Doppler detection of significant (>/= 70%) graft stenosis. RESULTS: In the test group the identification rate for mammary artery grafts was 100%, for saphenous vein grafts to left anterior descending coronary artery 91%, for vein grafts to right coronary artery 96%, and for vein grafts to circumflex artery 90%. Coronary flow reserve (the ratio between peak diastolic velocity under hyperaemia and at baseline) of < 1.9 (95% confidence interval 1.83 to 2.08) had 100% sensitivity, 98% specificity, 87.5% positive predictive value, and 100% negative predictive value for mammary artery graft stenosis. Coronary flow reserve of < 1.6 (95% CI 1.51 to 1.73) had 91% sensitivity, 87% specificity, 85.4% positive predictive value, and 92.3% negative predictive value for significant vein graft stenosis. CONCLUSIONS: Transthoracic Doppler can provide non-invasive assessment of CABG patency.

  13. The neural correlate of colour distances revealed with competing synaesthetic and real colours.

    PubMed

    Laeng, Bruno; Hugdahl, Kenneth; Specht, Karsten

    2011-03-01

    Synaesthetes claim to perceive illusory colours when reading alphanumeric symbols so that two colours are said to be bound to the same letter or digit (i.e., the colour of the ink, e.g., black, and an additional, synaesthetic, colour). To explore the neural correlates of this phenomenon, we used a Stroop single-letter colour-naming task and found that distances in colour space between the illusory and real colours of a letter target (as computed from either the RGB or CIExyY coordinates of colours) systematically influenced the degree of neuronal activation in colour-processing brain regions. The synaesthetes also activated the same fronto-parietal network during the classic colour-word Stroop task and single-letter tasks. We conclude that the same neural substrate that supports the conscious experience of colour, as triggered by physical wavelength, supports the experience of synaesthetic colours. Thus, two colour attributes (one that is wavelength-dependent and one that is illusory) can be bound to the same stimulus position and simultaneously engage the colour areas in proportion to their similarity in colour space. Copyright © 2009 Elsevier Srl. All rights reserved.

  14. 4D microvascular imaging based on ultrafast Doppler tomography.

    PubMed

    Demené, Charlie; Tiran, Elodie; Sieu, Lim-Anna; Bergel, Antoine; Gennisson, Jean Luc; Pernot, Mathieu; Deffieux, Thomas; Cohen, Ivan; Tanter, Mickael

    2016-02-15

    4D ultrasound microvascular imaging was demonstrated by applying ultrafast Doppler tomography (UFD-T) to the imaging of brain hemodynamics in rodents. In vivo real-time imaging of the rat brain was performed using ultrasonic plane wave transmissions at very high frame rates (18,000 frames per second). Such ultrafast frame rates allow for highly sensitive and wide-field-of-view 2D Doppler imaging of blood vessels far beyond conventional ultrasonography. Voxel anisotropy (100 μm × 100 μm × 500 μm) was corrected for by using a tomographic approach, which consisted of ultrafast acquisitions repeated for different imaging plane orientations over multiple cardiac cycles. UFT-D allows for 4D dynamic microvascular imaging of deep-seated vasculature (up to 20 mm) with a very high 4D resolution (respectively 100 μm × 100 μm × 100 μm and 10 ms) and high sensitivity to flow in small vessels (>1 mm/s) for a whole-brain imaging technique without requiring any contrast agent. 4D ultrasound microvascular imaging in vivo could become a valuable tool for the study of brain hemodynamics, such as cerebral flow autoregulation or vascular remodeling after ischemic stroke recovery, and, more generally, tumor vasculature response to therapeutic treatment. Copyright © 2015 Elsevier Inc. All rights reserved.

  15. Value of ultrasonography for detecting chronic injury of the lateral ligaments of the ankle joint compared with ultrasonography findings.

    PubMed

    Cheng, Y; Cai, Y; Wang, Y

    2014-01-01

    The aim of this study was to assess the accuracy of ultrasonography in the diagnosis of chronic lateral ankle ligament injury. A total of 120 ankles in 120 patients with a clinical suspicion of chronic ankle ligament injury were examined by ultrasonography by using a 5- to 17-MHz linear array transducer before surgery. The results of ultrasonography were compared with the operative findings. There were 18 sprains and 24 partial and 52 complete tears of the anterior talofibular ligament (ATFL); 26 sprains, 27 partial and 12 complete tears of the calcaneofibular ligament (CFL); and 1 complete tear of the posterior talofibular ligament (PTFL) at arthroscopy and operation. Compared with operative findings, the sensitivity, specificity and accuracy of ultrasonography were 98.9%, 96.2% and 84.2%, respectively, for injury of the ATFL and 93.8%, 90.9% and 83.3%, respectively, for injury of the CFL. The PTFL tear was identified by ultrasonography. The accuracy of identification between acute-on-chronic and subacute-chronic patients did not differ. The accuracies of diagnosing three grades of ATFL injuries were almost the same as those of diagnosing CFL injuries. Ultrasonography provides useful information for the evaluation of patients presenting with chronic pain after ankle sprain. Intraoperative findings are the reference standard. We demonstrated that ultrasonography was highly sensitive and specific in detecting chronic lateral ligments injury of the ankle joint.

  16. Compression ultrasonography of the lower extremity with portable vascular ultrasonography can accurately detect deep venous thrombosis in the emergency department.

    PubMed

    Crisp, Jonathan G; Lovato, Luis M; Jang, Timothy B

    2010-12-01

    Compression ultrasonography of the lower extremity is an established method of detecting proximal lower extremity deep venous thrombosis when performed by a certified operator in a vascular laboratory. Our objective is to determine the sensitivity and specificity of bedside 2-point compression ultrasonography performed in the emergency department (ED) with portable vascular ultrasonography for the detection of proximal lower extremity deep venous thrombosis. We did this by directly comparing emergency physician-performed ultrasonography to lower extremity duplex ultrasonography performed by the Department of Radiology. This was a prospective, cross-sectional study and diagnostic test assessment of a convenience sample of ED patients with a suspected lower extremity deep venous thrombosis, conducted at a single-center, urban, academic ED. All physicians had a 10-minute training session before enrolling patients. ED compression ultrasonography occurred before Department of Radiology ultrasonography and involved identification of 2 specific points: the common femoral and popliteal vessels, with subsequent compression of the common femoral and popliteal veins. The study result was considered positive for proximal lower extremity deep venous thrombosis if either vein was incompressible or a thrombus was visualized. Sensitivity and specificity were calculated with the final radiologist interpretation of the Department of Radiology ultrasonography as the criterion standard. A total of 47 physicians performed 199 2-point compression ultrasonographic examinations in the ED. Median number of examinations per physician was 2 (range 1 to 29 examinations; interquartile range 1 to 5 examinations). There were 45 proximal lower extremity deep venous thromboses observed on Department of Radiology evaluation, all correctly identified by ED 2-point compression ultrasonography. The 153 patients without proximal lower extremity deep venous thrombosis all had a negative ED compression

  17. Role of ultrasonography with color-Doppler in the emergency diagnosis of acute penile fracture: a case report.

    PubMed

    Buyukkaya, Ramazan; Buyukkaya, Ayla; Ozturk, Beyhan; Kayıkçı, Ali; Yazgan, Ömer

    2014-03-01

    Penile fracture is the rupture of tunica albuginea, typically resulting from blunt trauma, intercourse, or penile manipulation. Diagnosis is made clinically. Ultrasound is not used frequently in diagnosis of penile fracture but it provides a fast, non-invasive alternative to more often used MRI and cavernography. We aimed to present diagnostic ultrasound and color Doppler images of a patient with acute penile fracture in conjunction with literature.

  18. Surface Charge Measurement of SonoVue, Definity and Optison: A Comparison of Laser Doppler Electrophoresis and Micro-Electrophoresis.

    PubMed

    Ja'afar, Fairuzeta; Leow, Chee Hau; Garbin, Valeria; Sennoga, Charles A; Tang, Meng-Xing; Seddon, John M

    2015-11-01

    Microbubble (MB) contrast-enhanced ultrasonography is a promising tool for targeted molecular imaging. It is important to determine the MB surface charge accurately as it affects the MB interactions with cell membranes. In this article, we report the surface charge measurement of SonoVue, Definity and Optison. We compare the performance of the widely used laser Doppler electrophoresis with an in-house micro-electrophoresis system. By optically tracking MB electrophoretic velocity in a microchannel, we determined the zeta potentials of MB samples. Using micro-electrophoresis, we obtained zeta potential values for SonoVue, Definity and Optison of -28.3, -4.2 and -9.5 mV, with relative standard deviations of 5%, 48% and 8%, respectively. In comparison, laser Doppler electrophoresis gave -8.7, +0.7 and +15.8 mV with relative standard deviations of 330%, 29,000% and 130%, respectively. We found that the reliability of laser Doppler electrophoresis is compromised by MB buoyancy. Micro-electrophoresis determined zeta potential values with a 10-fold improvement in relative standard deviation. Copyright © 2015 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  19. Modern management of juvenile recurrent parotitis.

    PubMed

    Capaccio, P; Sigismund, P E; Luca, N; Marchisio, P; Pignataro, L

    2012-12-01

    To evaluate modern diagnostic and therapeutic management of juvenile recurrent parotitis, and to show the benefits of operative sialoendoscopy on the basis of our experience in 14 patients and the results of others. Ultrasonography is sensitive in detecting the pathological features of juvenile recurrent parotitis. Interventional sialoendoscopy is a safe and effective method of treating the disease. In our case series, after a mean follow-up time of 30 months only 5 patients experienced recurrence of symptoms, with a mean symptom-free period of 20 months. The use of modern, minimally invasive diagnostic tools such as colour Doppler ultrasonography, magnetic resonance sialography and sialoendoscopy represents a new frontier in the management of juvenile recurrent parotitis. Operative sialoendoscopy also has the important therapeutic benefit of reducing the number of recurrences of acute episodes of parotitis, thus giving patients a better quality of life until puberty.

  20. An unexpected cause of small bowel obstruction in an adult patient: midgut volvulus

    PubMed Central

    Söker, Gökhan; Yılmaz, Cengiz; Karateke, Faruk; Gülek, Bozkurt

    2014-01-01

    The most important complication of intestinal malrotation is midgut volvulus because it may lead to intestinal ischaemia and necrosis. A 29-year-old male patient was admitted to the emergency department with abdominal pain. Ultrasonography (US), colour Doppler ultrasonography (CDUS), CT and barium studies were carried out. On US and CDUS, twisting of intestinal segments around the superior mesenteric artery (SMA) and superior mesenteric vein (SMV) and alteration of the SMA–SMV relationship were detected. CT demonstrated that the small intestine was making a rotation around the SMA and SMV, which amounted to more than 360°. The upper gastrointestinal barium series revealed a corkscrew appearance of the duodenum and proximal jejunum, which is a pathognomonic finding of midgut volvulus. Prior knowledge of characteristic imaging findings of midgut volvulus is essential in order to reach proper diagnosis and establish proper treatment before the development of intestinal ischaemia and necrosis. PMID:24811563

  1. Contrast-enhanced ultrasonography for the detection of joint vascularity in arthritis--subjective grading versus computer-aided objective quantification.

    PubMed

    Klauser, A S; Franz, M; Bellmann Weiler, R; Gruber, J; Hartig, F; Mur, E; Wick, M C; Jaschke, W

    2011-12-01

    To compare joint inflammation assessment using subjective grading of power Doppler ultrasonography (PDUS) and contrast-enhanced ultrasonography (CEUS) versus computer-aided objective CEUS quantification. 37 joints of 28 patients with arthritis of different etiologies underwent B-mode ultrasonography, PDUS, and CEUS using a second-generation contrast agent. Synovial thickness, extent of vascularized pannus and intensity of vascularization were included in a 4-point PDUS and CEUS grading system. Subjective CEUS and PDUS scores were compared to computer-aided objective CEUS quantification using Qontrast® software for the calculation of the signal intensity (SI) and the ratio of SI for contrast enhancement. The interobserver agreement for subjective scoring was good to excellent (κ = 0.8 - 1.0; P < 0.0001). Computer-aided objective CEUS quantification correlated statistically significantly with subjective CEUS (P < 0.001) and PDUS grading (P < 0.05). The Qontrast® SI ratio correlated with subjective CEUS (P < 0.02) and PDUS grading (P < 0.03). Clinical activity did not correlate with vascularity or synovial thickening (P = N. S.) and no correlation between synovial thickening and vascularity extent could be found, neither using PDUS nor CEUS (P = N. S.). Both subjective CEUS grading and objective CEUS quantification are valuable for assessing joint vascularity in arthritis and computer-aided CEUS quantification may be a suitable objective tool for therapy follow-up in arthritis. © Georg Thieme Verlag KG Stuttgart · New York.

  2. Improved colour matching technique for fused nighttime imagery with daytime colours

    NASA Astrophysics Data System (ADS)

    Hogervorst, Maarten A.; Toet, Alexander

    2016-10-01

    Previously, we presented a method for applying daytime colours to fused nighttime (e.g., intensified and LWIR) imagery (Toet and Hogervorst, Opt.Eng. 51(1), 2012). Our colour mapping not only imparts a natural daylight appearance to multiband nighttime images but also enhances the contrast and visibility of otherwise obscured details. As a result, this colourizing method leads to increased ease of interpretation, better discrimination and identification of materials, faster reaction times and ultimately improved situational awareness (Toet e.a., Opt.Eng.53(4), 2014). A crucial step in this colouring process is the choice of a suitable colour mapping scheme. When daytime colour images and multiband sensor images of the same scene are available the colour mapping can be derived from matching image samples (i.e., by relating colour values to sensor signal intensities). When no exact matching reference images are available the colour transformation can be derived from the first-order statistical properties of the reference image and the multiband sensor image (Toet, Info. Fus. 4(3), 2003). In the current study we investigated new colour fusion schemes that combine the advantages of the both methods, using the correspondence between multiband sensor values and daytime colours (1st method) in a smooth transformation (2nd method). We designed and evaluated three new fusion schemes that focus on: i) a closer match with the daytime luminances, ii) improved saliency of hot targets and iii) improved discriminability of materials

  3. The colour of an avifauna: A quantitative analysis of the colour of Australian birds

    PubMed Central

    Delhey, Kaspar

    2015-01-01

    Animal coloration is a poorly-understood aspect of phenotypic variability. Here I expand initial studies of the colour gamut of birds by providing the first quantitative description of the colour variation of an entire avifauna: Australian landbirds (555 species). The colour of Australian birds occupies a small fraction (19%) of the entire possible colour space and colour variation is extremely uneven. Most colours are unsaturated, concentrated in the centre of colour space and based on the deposition of melanins. Other mechanisms of colour production are less common but account for larger portions of colour space and for most saturated colours. Male colours occupy 45–25% more colour space than female colours, indicating that sexual dichromatism translates into a broader range of male colours. Male-exclusive colours are often saturated, at the edge of chromatic space, and have most likely evolved for signalling. While most clades of birds occupy expected or lower-than-expected colour volumes, parrots and cockatoos (Order Psittaciformes) occupy a much larger volume than expected. This uneven distribution of colour variation across mechanisms of colour production, sexes and clades is probably shared by avifaunas in other parts of the world, but this remains to be tested with comparable data. PMID:26679370

  4. Prenatal Imaging: Ultrasonography and Magnetic Resonance Imaging

    PubMed Central

    Reddy, Uma M.; Filly, Roy A.; Copel, Joshua A.

    2009-01-01

    The Eunice Kennedy Shriver National Institute of Child Health and Human Development held a workshop on September 18–19, 2006, to summarize the available evidence on the role and performance of current fetal imaging technology and to establish a research agenda. Ultrasonography is the imaging modality of choice for pregnancy evaluation due to its relatively low cost, real-time capability, safety, and operator comfort and experience. First-trimester ultrasonography extends the available window for fetal observation and raises the possibility of performing an early anatomic survey. Three-dimensional ultrasonography has the potential to expand the clinical application of ultrasonography by permitting local acquisition of volumes and remote review and interpretation at specialized centers. New advances allow performance of fetal magnetic resonance imaging (MRI) without maternal or fetal sedation, with improved characterization and prediction of prognosis of certain fetal central nervous system anomalies such as ventriculomegaly when compared with ultrasonography. Fewer data exist on the usefulness of fetal MRI for non–central nervous system anomalies. PMID:18591320

  5. The colour of pain: can patients use colour to describe osteoarthritis pain?

    PubMed

    Wylde, Vikki; Wells, Victoria; Dixon, Samantha; Gooberman-Hill, Rachael

    2014-03-01

    The aim of the present study was to explore patients' views on the acceptability and feasibility of using colour to describe osteoarthritis (OA) pain, and whether colour could be used to communicate pain to healthcare professionals. Six group interviews were conducted with 17 patients with knee OA. Discussion topics included first impressions about using colour to describe pain, whether participants could associate their pain with colour, how colours related to changes to intensity and different pain qualities, and whether they could envisage using colour to describe pain to healthcare professionals. The group interviews indicated that, although the idea of using colour was generally acceptable, it did not suit all participants as a way of describing their pain. The majority of participants chose red to describe high-intensity pain; the reasons given were because red symbolized inflammation, fire, anger and the stop signal in a traffic light system. Colours used to describe the absence of pain were chosen because of their association with positive emotional feelings, such as purity, calmness and happiness. A range of colours was chosen to represent changes in pain intensity. Aching pain was consistently identified as being associated with colours such as grey or black, whereas sharp pain was described using a wider selection of colours. The majority of participants thought that they would be able to use colour to describe their pain to healthcare professionals, although issues around the interpretability and standardization of colour were raised. For some patients, using colour to describe their pain experience may be a useful tool to improve doctor-patient communication. Copyright © 2013 John Wiley & Sons, Ltd.

  6. Value of ultrasonography for detecting chronic injury of the lateral ligaments of the ankle joint compared with ultrasonography findings

    PubMed Central

    Cheng, Y; Cai, Y

    2014-01-01

    Objective: The aim of this study was to assess the accuracy of ultrasonography in the diagnosis of chronic lateral ankle ligament injury. Methods: A total of 120 ankles in 120 patients with a clinical suspicion of chronic ankle ligament injury were examined by ultrasonography by using a 5- to 17-MHz linear array transducer before surgery. The results of ultrasonography were compared with the operative findings. Results: There were 18 sprains and 24 partial and 52 complete tears of the anterior talofibular ligament (ATFL); 26 sprains, 27 partial and 12 complete tears of the calcaneofibular ligament (CFL); and 1 complete tear of the posterior talofibular ligament (PTFL) at arthroscopy and operation. Compared with operative findings, the sensitivity, specificity and accuracy of ultrasonography were 98.9%, 96.2% and 84.2%, respectively, for injury of the ATFL and 93.8%, 90.9% and 83.3%, respectively, for injury of the CFL. The PTFL tear was identified by ultrasonography. The accuracy of identification between acute-on-chronic and subacute–chronic patients did not differ. The accuracies of diagnosing three grades of ATFL injuries were almost the same as those of diagnosing CFL injuries. Conclusion: Ultrasonography provides useful information for the evaluation of patients presenting with chronic pain after ankle sprain. Advances in knowledge: Intraoperative findings are the reference standard. We demonstrated that ultrasonography was highly sensitive and specific in detecting chronic lateral ligments injury of the ankle joint. PMID:24352708

  7. Colour vision deficiency.

    PubMed

    Simunovic, M P

    2010-05-01

    Colour vision deficiency is one of the commonest disorders of vision and can be divided into congenital and acquired forms. Congenital colour vision deficiency affects as many as 8% of males and 0.5% of females--the difference in prevalence reflects the fact that the commonest forms of congenital colour vision deficiency are inherited in an X-linked recessive manner. Until relatively recently, our understanding of the pathophysiological basis of colour vision deficiency largely rested on behavioural data; however, modern molecular genetic techniques have helped to elucidate its mechanisms. The current management of congenital colour vision deficiency lies chiefly in appropriate counselling (including career counselling). Although visual aids may be of benefit to those with colour vision deficiency when performing certain tasks, the evidence suggests that they do not enable wearers to obtain normal colour discrimination. In the future, gene therapy remains a possibility, with animal models demonstrating amelioration following treatment.

  8. A transcranial Doppler sonography study of shoot/don't-shoot responding.

    PubMed

    Schultz, Natasha B; Matthews, Gerald; Warm, Joel S; Washburn, David A

    2009-08-01

    The purpose of this study was to examine the relationship between changes in cerebral blood-flow velocity and performance on a speeded shoot/don't-shoot task. Brain activity as indicated by cerebral blood-flow velocity (hemovelocity) was recorded using the transcranial Doppler ultrasonography. A shoot/don't-shoot decision-making task presented participants with threat/nonthreat stimuli in the form of bull's-eye images of various colors. Participants were required to shoot threat targets using a laser-modified handgun. Results support a vigilance decrement in both the performance measures and hemovelocity. Performance, as measured by reaction time, number of hits, and marksmanship, decreased across the length of the vigil. Hemovelocity slowed across the left and right hemispheres as the task progressed, and hemovelocity was slower in the right hemisphere than in the left hemisphere.

  9. How useful is abdominal ultrasonography in dogs with diarrhoea?

    PubMed

    Mapletoft, E K; Allenspach, K; Lamb, C R

    2018-01-01

    To assess the utility of abdominal ultrasonography in the diagnostic work-up of dogs with diarrhoea. Retrospective cross-sectional study based on a referral population of dogs with diarrhoea. Associations between the clinical signs, use of abdominal ultrasonography, results of abdominal ultrasonography and subsequent work-up were examined. The utility of abdominal ultrasonography was scored as high, moderate, none or counterproductive based on review of medical records. Medical records of 269 dogs were reviewed, of which 149 (55%) had abdominal ultrasonography. The most frequent result was no ultrasonographic abnormalities affecting the intestine in 65 (44%) dogs. Ultrasonography results were associated with subsequent work-up as follows: (1) no detected abnormalities and dietary trial; (2) focal thickening of the intestinal wall, loss of intestinal wall layers or enlarged abdominal lymph nodes and ultrasound-guided fine-needle aspirates; (3) diffuse thickening of the intestinal wall or hyperechoic striations in the small intestinal mucosa and endoscopy; and (4) small intestinal foreign body and coeliotomy. Abdominal ultrasonography was considered to be diagnostic without further testing in only four (3%) dogs: two had a portosystemic shunt identified ultrasonographically, one had a linear foreign body and one had a perforated pyloric ulcer. Abdominal ultrasonography had moderate utility in 56 (38%) dogs and no utility in 79 (53%) dogs. Abdominal ultrasonography was considered counterproductive in 10 (7%) dogs because results were either falsely negative or falsely positive. These results should prompt clinicians to reconsider routine use of abdominal ultrasonography in dogs with diarrhoea. © 2017 British Small Animal Veterinary Association.

  10. Measurements and modelling of the influence of dentine colour and enamel on tooth colour.

    PubMed

    Battersby, Paul D; Battersby, Stephen J

    2015-03-01

    We provide a quantitative predictive model for the extent to which coloured dentine, visible through the enamel, contributes to tooth colour. Our model uses (L(*),a(*),b(*)) measurements rather than spectral measurements. We have used a model system, composed of a slice of bovine enamel placed on top of coloured paper. We have measured the colour of the enamel-paper combination, as an analogue for a tooth, and have related this to the colour of the paper, as an analogue for dentine. By changing the paper colour, we have been able to explore how the colour of dentine determines tooth colour, according to our model system. We have also compared hydrated and desiccated samples. In qualitative terms, superimposing the enamel on top of the paper increases the "lightness" for all colours tested except white while simultaneously reducing the chromaticity, a measure of the extent to which the colour differs from grey. Desiccated enamel is much more effective at increasing the lightness and reducing the chromaticity than hydrated enamel. Quantitatively, our measurements are reproduced by the mathematical model we have developed to within 2% in "lightness" and about 8% in chromaticity. We are able to predict the colour of an analogue for a tooth, composed of bovine enamel and coloured paper, from the colour of an analogue for the dentine, the coloured paper alone, with good accuracy. This understanding provides insights into the role of dentine colour in determining tooth colour. Our work helps quantify the importance of dentine colour, compared to other, extrinsic causes of colour, such as staining, in determining the visible colour of teeth. Our predicted colours represent a baseline to which extrinsic sources will add. Copyright © 2015. Published by Elsevier Ltd.

  11. Colour constancy in insects.

    PubMed

    Chittka, Lars; Faruq, Samia; Skorupski, Peter; Werner, Annette

    2014-06-01

    Colour constancy is the perceptual phenomenon that the colour of an object appears largely unchanged, even if the spectral composition of the illuminating light changes. Colour constancy has been found in all insect species so far tested. Especially the pollinating insects offer a remarkable opportunity to study the ecological significance of colour constancy since they spend much of their adult lives identifying and choosing between colour targets (flowers) under continuously changing ambient lighting conditions. In bees, whose colour vision is best studied among the insects, the compensation provided by colour constancy is only partial and its efficiency depends on the area of colour space. There is no evidence for complete 'discounting' of the illuminant in bees, and the spectral composition of the light can itself be used as adaptive information. In patchy illumination, bees adjust their spatial foraging to minimise transitions between variously illuminated zones. Modelling allows the quantification of the adaptive benefits of various colour constancy mechanisms in the economy of nature. We also discuss the neural mechanisms and cognitive operations that might underpin colour constancy in insects.

  12. US imaging and color Doppler in patients undergoing inhibitory therapy with calcitriol for secondary hyperparathyroidism.

    PubMed

    Pretolesi, F; Silvestri, E; Di Maio, G; Martinoli, C; Onetto, F; Sala, P; Derchi, L E

    1997-01-01

    The aim of this study was to evaluate the changes in volume, structure, and flow pattern of parathyroid glands in uremic patients with secondary hyperparathyroidism treated with long-term intravenous calcitriol (CTL) therapy. Ultrasonography was used to follow-up volume changes occurring in 18 enlarged glands in 11 patients during an 18-month period; in 6 of these cases, 11 glands were followed-up also with color-Doppler to monitor variations in flow pattern. Vascularization was classified using three grades: grade 0 = no color signal; grade I = vessels covering less than 50 % of glandular cross-sectional area; grade II = vascular signals covering more than 50 % of glandular cross-sectional area. No significant changes in volume were demonstrated during the 18 months of follow-up. On the contrary, significant decrease in flow was observed with almost complete disappearance of color-Doppler signals. This finding related well with the observed decrease in parathormone blood levels. Lack of volume changes during medical therapy demonstrates the inability of US alone to monitor the effect of this treatment on the parathyroid glands. Conversely, the observed intraglandular flow reduction indicates the possibility to use color Doppler to monitor the effects of CLT in uremic hemodialyzed patients with secondary hyperparathyroidism. This imaging procedure can be proposed for follow-up of the response of the parathyroid glands to therapy.

  13. [Changes of renal blood flow during organ-associated foot reflexology measured by color Doppler sonography].

    PubMed

    Sudmeier, I; Bodner, G; Egger, I; Mur, E; Ulmer, H; Herold, M

    1999-06-01

    Using colour Doppler sonography blood flow changes of the right kidney during foot reflexology were determined in a placebo-controlled, double-blind, randomised study. 32 healthy young adults (17 women, 15 men) were randomly assigned to the verum or placebo group. The verum group received foot reflexology at zones corresponding to the right kidney, the placebo group was treated on other foot zones. Before, during and after foot reflexology the blood flow of three vessels of the right kidney was measured using colour Doppler sonography. Systolic peak velocity and end diastolic peak velocity were measured in cm/s, and the resistive index, a parameter of the vascular resistance, was calculated. The resistive index in the verum group showed a highly significant decrease (p

  14. Quantifying plant colour and colour difference as perceived by humans using digital images.

    PubMed

    Kendal, Dave; Hauser, Cindy E; Garrard, Georgia E; Jellinek, Sacha; Giljohann, Katherine M; Moore, Joslin L

    2013-01-01

    Human perception of plant leaf and flower colour can influence species management. Colour and colour contrast may influence the detectability of invasive or rare species during surveys. Quantitative, repeatable measures of plant colour are required for comparison across studies and generalisation across species. We present a standard method for measuring plant leaf and flower colour traits using images taken with digital cameras. We demonstrate the method by quantifying the colour of and colour difference between the flowers of eleven grassland species near Falls Creek, Australia, as part of an invasive species detection experiment. The reliability of the method was tested by measuring the leaf colour of five residential garden shrub species in Ballarat, Australia using five different types of digital camera. Flowers and leaves had overlapping but distinct colour distributions. Calculated colour differences corresponded well with qualitative comparisons. Estimates of proportional cover of yellow flowers identified using colour measurements correlated well with estimates obtained by measuring and counting individual flowers. Digital SLR and mirrorless cameras were superior to phone cameras and point-and-shoot cameras for producing reliable measurements, particularly under variable lighting conditions. The analysis of digital images taken with digital cameras is a practicable method for quantifying plant flower and leaf colour in the field or lab. Quantitative, repeatable measurements allow for comparisons between species and generalisations across species and studies. This allows plant colour to be related to human perception and preferences and, ultimately, species management.

  15. Quantifying Plant Colour and Colour Difference as Perceived by Humans Using Digital Images

    PubMed Central

    Kendal, Dave; Hauser, Cindy E.; Garrard, Georgia E.; Jellinek, Sacha; Giljohann, Katherine M.; Moore, Joslin L.

    2013-01-01

    Human perception of plant leaf and flower colour can influence species management. Colour and colour contrast may influence the detectability of invasive or rare species during surveys. Quantitative, repeatable measures of plant colour are required for comparison across studies and generalisation across species. We present a standard method for measuring plant leaf and flower colour traits using images taken with digital cameras. We demonstrate the method by quantifying the colour of and colour difference between the flowers of eleven grassland species near Falls Creek, Australia, as part of an invasive species detection experiment. The reliability of the method was tested by measuring the leaf colour of five residential garden shrub species in Ballarat, Australia using five different types of digital camera. Flowers and leaves had overlapping but distinct colour distributions. Calculated colour differences corresponded well with qualitative comparisons. Estimates of proportional cover of yellow flowers identified using colour measurements correlated well with estimates obtained by measuring and counting individual flowers. Digital SLR and mirrorless cameras were superior to phone cameras and point-and-shoot cameras for producing reliable measurements, particularly under variable lighting conditions. The analysis of digital images taken with digital cameras is a practicable method for quantifying plant flower and leaf colour in the field or lab. Quantitative, repeatable measurements allow for comparisons between species and generalisations across species and studies. This allows plant colour to be related to human perception and preferences and, ultimately, species management. PMID:23977275

  16. Evaluation of lymph node perfusion using continuous mode harmonic ultrasonography with a second-generation contrast agent.

    PubMed

    Rubaltelli, Leopoldo; Khadivi, Yeganeh; Tregnaghi, Alberto; Stramare, Roberto; Ferro, Federica; Borsato, Simonetta; Fiocco, Ugo; Adami, Fausto; Rossi, Carlo Riccardo

    2004-06-01

    To evaluate the contribution of continuous mode contrast-enhanced harmonic ultrasonography (CE-HUS) with a second-generation contrast agent to the characterization of superficial lymphadenopathies with respect to conventional ultrasonographic techniques (B-mode and power Doppler). Fifty-six lymph nodes from 45 patients were studied both by conventional techniques and by CE-HUS. The dimensions, intranodal architecture, margins, and location of vessels were evaluated. Subsequently, all the lymph nodes were examined by CE-HUS, and enhancement of echogenicity was evaluated. The diagnoses obtained by means of fine-needle aspiration cytologic examination, surgical biopsy, or both were compared with those obtained by ultrasonography. Of the lymph nodes examined, 30 were benign and 26 were malignant (18 metastases and 8 non-Hodgkin lymphomas). The study using CE-HUS showed intense homogeneous enhancement in 28 of 30 reactive lymph nodes; perfusion defects in 17, of which 15 were neoplastic and 2 were inflammatory; intense but inhomogeneous speckled enhancement in the early arterial phase in 5 cases of lymphoma; and, last, scarce or absent intranodal enhancement in 4 metastases. The specificity, sensitivity, and accuracy of conventional techniques in differentiation between benign and malignant lymph nodes were 76%, 80%, and 78% versus 93%, 92%, and 92.8% for CE-HUS. The increase in correct diagnoses was significant (P = .05) when conventional ultrasonography was tested against CE-HUS. Superficial lymph nodes can be characterized as being neoplastic or benign with a high degree of diagnostic accuracy on the basis of the perfusion characteristics evaluated by CE-HUS. This technique has been shown to afford a higher degree of accuracy than currently obtainable by any other ultrasonographic technique.

  17. Understanding WCAG2.0 Colour Contrast Requirements Through 3D Colour Space Visualisation.

    PubMed

    Sandnes, Frode Eika

    2016-01-01

    Sufficient contrast between text and background is needed to achieve sufficient readability. WCAG2.0 provides a specific definition of sufficient contrast on the web. However, the definition is hard to understand and most designers thus use contrast calculators to validate their colour choices. Often, such checks are performed after design and this may be too late. This paper proposes a colour selection approach based on three-dimensional visualisation of the colour space. The complex non-linear relationships between the colour components become comprehendible when viewed in 3D. The method visualises the available colours in an intuitive manner and allows designers to check a colour against the set of other valid colours. Unlike the contrast calculators, the proposed method is proactive and fun to use. A colour space builder was developed and the resulting models were viewed with a point cloud viewer. The technique can be used as both a design tool and a pedagogical aid to teach colour theory and design.

  18. Exploring the functional nature of synaesthetic colour: Dissociations from colour perception and imagery.

    PubMed

    Chiou, Rocco; Rich, Anina N; Rogers, Sebastian; Pearson, Joel

    2018-08-01

    Individuals with grapheme-colour synaesthesia experience anomalous colours when reading achromatic text. These unusual experiences have been said to resemble 'normal' colour perception or colour imagery, but studying the nature of synaesthesia remains difficult. In the present study, we report novel evidence that synaesthetic colour impacts conscious vision in a way that is different from both colour perception and imagery. Presenting 'normal' colour prior to binocular rivalry induces a location-dependent suppressive bias reflecting local habituation. By contrast, a grapheme that evokes synaesthetic colour induces a facilitatory bias reflecting priming that is not constrained to the inducing grapheme's location. This priming does not occur in non-synaesthetes and does not result from response bias. It is sensitive to diversion of visual attention away from the grapheme, but resistant to sensory perturbation, reflecting a reliance on cognitive rather than sensory mechanisms. Whereas colour imagery in non-synaesthetes causes local priming that relies on the locus of imagined colour, imagery in synaesthetes caused global priming not dependent on the locus of imagery. These data suggest a unique psychophysical profile of high-level colour processing in synaesthetes. Our novel findings and method will be critical to testing theories of synaesthesia and visual awareness. Copyright © 2018 Elsevier B.V. All rights reserved.

  19. Fruit over sunbed: carotenoid skin colouration is found more attractive than melanin colouration.

    PubMed

    Lefevre, Carmen E; Perrett, David I

    2015-01-01

    Skin colouration appears to play a pivotal part in facial attractiveness. Skin yellowness contributes to an attractive appearance and is influenced both by dietary carotenoids and by melanin. While both increased carotenoid colouration and increased melanin colouration enhance apparent health in Caucasian faces by increasing skin yellowness, it remains unclear, firstly, whether both pigments contribute to attractiveness judgements, secondly, whether one pigment is clearly preferred over the other, and thirdly, whether these effects depend on the sex of the face. Here, in three studies, we examine these questions using controlled facial stimuli transformed to be either high or low in (a) carotenoid colouration, or (b) melanin colouration. We show, firstly, that both increased carotenoid colouration and increased melanin colouration are found attractive compared to lower levels of these pigments. Secondly, we show that carotenoid colouration is consistently preferred over melanin colouration when levels of colouration are matched. In addition, we find an effect of the sex of stimuli with stronger preferences for carotenoids over melanin in female compared to male faces, irrespective of the sex of the observer. These results are interpreted as reflecting preferences for sex-typical skin colouration: men have darker skin than women and high melanization in male faces may further enhance this masculine trait, thus carotenoid colouration is not less desirable, but melanin colouration is relatively more desirable in males compared to females. Taken together, our findings provide further support for a carotenoid-linked health-signalling system that is highly important in mate choice.

  20. The role of transvaginal power Doppler ultrasound in the differential diagnosis of benign intrauterine focal lesions.

    PubMed

    Cogendez, Ebru; Eken, Meryem Kurek; Bakal, Nuray; Gun, Ismet; Kaygusuz, Ecmel Isik; Karateke, Ates

    2015-10-01

    The purpose of this prospective study was to assess the role of power Doppler imaging in the differential diagnosis of benign intrauterine focal lesions such as endometrial polyps and submucous myomas using the characteristics of power Doppler flow mapping. A total of 480 premenopausal patients with abnormal uterine bleeding were evaluated by transvaginal ultrasonography (TVS) searching for intrauterine pathology. Sixty-four patients with a suspicious focal endometrial lesion received saline infusion sonography (SIS) after TVS. Fifty-eight patients with focal endometrial lesions underwent power Doppler ultrasound (PDUS). Three different vascular flow patterns were defined: Single vessel pattern, multiple vessel pattern, and circular flow pattern. Finally, hysteroscopic resection was performed in all cases, and Doppler flow characteristics were then compared with the final histopathological findings. Histopathological results were as follows: endometrial polyp: 40 (69 %), submucous myoma: 18 (31 %). Of the cases with endometrial polyps, 80 % demonstrated a single vessel pattern, 7.5 % a multiple vessel pattern, and 0 % a circular pattern. Vascularization was not observed in 12.5 % of patients with polyps. Of the cases with submucousal myomas, 72.2 % demonstrated a circular flow pattern, 27.8 % a multiple vessel pattern, and none of them showed a single vessel pattern. The sensitivity, specificity, and positive and negative predictive values of the single vessel pattern in diagnosing endometrial polyps were 80, 100, 100, and 69.2 %, respectively; and for the circular pattern in diagnosing submucous myoma, these were 72.2, 100, 100, and 88.9 %, respectively. Power Doppler blood flow mapping is a useful, practical, and noninvasive diagnostic method for the differential diagnosis of benign intrauterine focal lesions. Especially in cases of recurrent abnormal uterine bleeding, recurrent abortion, and infertility, PDUS can be preferred as a first-line diagnostic method.

  1. Memory colours and colour quality evaluation of conventional and solid-state lamps.

    PubMed

    Smet, Kevin A G; Ryckaert, Wouter R; Pointer, Michael R; Deconinck, Geert; Hanselaer, Peter

    2010-12-06

    A colour quality metric based on memory colours is presented. The basic idea is simple. The colour quality of a test source is evaluated as the degree of similarity between the colour appearance of a set of familiar objects and their memory colours. The closer the match, the better the colour quality. This similarity was quantified using a set of similarity distributions obtained by Smet et al. in a previous study. The metric was validated by calculating the Pearson and Spearman correlation coefficients between the metric predictions and the visual appreciation results obtained in a validation experiment conducted by the authors as well those obtained in two independent studies. The metric was found to correlate well with the visual appreciation of the lighting quality of the sources used in the three experiments. Its performance was also compared with that of the CIE colour rendering index and the NIST colour quality scale. For all three experiments, the metric was found to be significantly better at predicting the correct visual rank order of the light sources (p < 0.1).

  2. Colour Perception in ADHD

    ERIC Educational Resources Information Center

    Banaschewski, Tobias; Ruppert, Sinje; Tannock, Rosemary; Albrecht, Bjorn; Becker, Andreas; Uebel, Henrik; Sergeant, Joseph A.; Rothenberger, Aribert

    2006-01-01

    Attention-deficit/hyperactivity disorder (ADHD) is associated with unexplained impairments on speeded naming of coloured stimuli. These deficits may reflect hypofunctioning retinal dopaminergic mechanisms impairing particularly blue-yellow colour discrimination. Colour perception and rapid colour naming ability were investigated in 14 children…

  3. [The application of Doppler broadening and Doppler shift to spectral analysis].

    PubMed

    Xu, Wei; Fang, Zi-shen

    2002-08-01

    The distinction between Doppler broadening and Doppler shift has analyzed, Doppler broadening locally results from the distribution of velocities of the emitting particles, the line width gives the information on temperature of emitting particles. Doppler shift results when the emitting particles have a bulk non random flow velocity in a particular direction, the drift of central wavelength gives the information on flow velocity of emitting particles, and the Doppler shift only drifts the profile of line without changing the width. The difference between Gaussian fitting and the distribution of chord-integral line shape have also been discussed. The distribution of H alpha spectral line shape has been derived from the surface of limiter in HT-6M Tokamak with optical spectroscope multichannel analysis (OSMA), the result by double Gaussian fitting shows that the line shape make up of two port, the emitting of reflect particles with higher energy and the release particle from the limiter surface. Ion temperature and recycling particle flow velocity have been obtained from Doppler broadening and Doppler shift.

  4. Early quantitative evaluation of a tumor vasculature disruptive agent AVE8062 using dynamic contrast-enhanced ultrasonography.

    PubMed

    Lavisse, Sonia; Lejeune, Pascale; Rouffiac, Valérie; Elie, Nicolas; Bribes, Estelle; Demers, Brigitte; Vrignaud, Patricia; Bissery, Marie-Christine; Brulé, Aude; Koscielny, Serge; Péronneau, Pierre; Lassau, Nathalie

    2008-02-01

    To evaluate the early tumor vasculature disrupting effects of the AVE8062 molecule and the feasibility of dynamic contrast-enhanced ultrasonography (DCE-US) in the quantitative assessment of these effects. AVE8062 was administered at a single dose (41 mg/kg) to 40 melanoma-bearing nude mice, which were all imaged before and after drug administration (5 + 15 minutes, 1, 6, and 24 hours). Using an ultrasound scanner (Aplio, Toshiba), intratumor vessels were counted in power Doppler mode and tumor microvasculature was assessed in a specific harmonic mode associated with a perfusion and quantification software for contrast-uptake quantification (Sonovue, Bracco). The peak intensity (PI), time-to-PI (T PI), and full-width at half maximum (FWHM) were extracted from the time-intensity curves expressed as linear raw data. Histologic analysis evaluated microvessel density (MVD) and necrosis at each time point studied. Statistical significance was estimated (paired sum rank and Mann-Whitney tests) to evaluate drug activity and to compare its efficacy at the different time points. In power Doppler mode, intratumoral vessels depletion started 15 minutes postinjection (32%, P = 0.004) and the decrease was maximal at 6 hours (51%, P = 0.002). PI decreased by 3.5- and 45.7-fold at 1 and 6 hours, respectively, compared with preinjection values (P = 0.016 and P = 0.008). The decrease at 6 hours was significantly different from the variation at 1 hour (P = 0.0012) and at 24 hours (P = 0.0008). T PI and FWHM showed a significant increase exclusively at 6 hours (P = 0.0034, P = 0.0039). Histology revealed significantly decreased MVD and increased necrosis at 24 hours (P < 0.01). DCE-US allowed quantitative in vivo evaluation of the functional effects of AVE8062, which was found most effective on tumoral microvasculature 6 hours after its administration. A clinical phase-1 study of AVE8062 is ongoing using the same ultrasonography methodology before and 6 and 24 hours

  5. Clinical utility of eco-color-power Doppler ultrasonography and contrast enhanced magnetic resonance imaging for interpretation and quantification of joint synovitis: a review.

    PubMed

    Carotti, Marina; Galeazzi, Vittoria; Catucci, Francesca; Zappia, Marcello; Arrigoni, Francesco; Barile, Antonio; Giovagnoni, Andrea

    2018-01-19

    With the introduction of new biologics such as anti-TNF-alpha antibodies and other therapies in the treatment of inflammatory arthritis, capable of halting joint destruction and functional disability, there are new pressures on diagnostic and prognostic imaging. Early demonstration of pre-erosive inflammatory features and monitoring of the long-term effects of treatment are becoming increasingly important. Early detection of synovitis offers advantages in terms of allowing early instigation of therapy and may allow the identification of those patients displaying more aggressive disease who might benefit from early intervention with expensive DMARD therapy. Advanced imaging techniques such as ultrasound (US) and magnetic resonance imaging (MRI) have focussed on the demonstration and quantification of synovitis and allow early diagnosis of inflammatory arthropathies such as rheumatoid arthritis (RA) and psoriatic arthritis (PsA). Synovitis represents a potential surrogate measure of disease activity that can be monitored using either MRI or US; the techniques have, generally, focused on monitoring synovial volume or quality as assessed by its vascularity. However to achieve these goals, standardisation and validation of US and MRI are required to ensure accurate diagnosis, reproducibility and reliability. Each modality has different strengths and weaknesses and levels of validation. This article aims to increase the awareness of radiologists and rheumatologists about this field and to encourage them to participate and contribute to the ongoing development of these modalities. Without this collaboration, it is unlikely that these modalities will reach their full potential in the field of rheumatological imaging. This review is in two parts. The first part addresses the role of US and colour or power Doppler sonography (PDUS) in the detection and monitoring of synovitis in inflammatory arthropathies. The second part will look at advanced MR imaging and Dynamic contrast

  6. Point-of-care ultrasonography by pediatric emergency medicine physicians.

    PubMed

    Marin, Jennifer R; Lewiss, Resa E

    2015-04-01

    Emergency physicians have used point-of-care ultrasonography since the 1990 s. Pediatric emergency medicine physicians have more recently adopted this technology. Point-of-care ultrasonography is used for various scenarios, particularly the evaluation of soft tissue infections or blunt abdominal trauma and procedural guidance. To date, there are no published statements from national organizations specifically for pediatric emergency physicians describing the incorporation of point-of-care ultrasonography into their practice. This document outlines how pediatric emergency departments may establish a formal point-of-care ultrasonography program. This task includes appointing leaders with expertise in point-of-care ultrasonography, effectively training and credentialing physicians in the department, and providing ongoing quality assurance reviews. Copyright © 2015 by the American Academy of Pediatrics.

  7. Object knowledge modulates colour appearance.

    PubMed

    Witzel, Christoph; Valkova, Hanna; Hansen, Thorsten; Gegenfurtner, Karl R

    2011-01-01

    We investigated the memory colour effect for colour diagnostic artificial objects. Since knowledge about these objects and their colours has been learned in everyday life, these stimuli allow the investigation of the influence of acquired object knowledge on colour appearance. These investigations are relevant for questions about how object and colour information in high-level vision interact as well as for research about the influence of learning and experience on perception in general. In order to identify suitable artificial objects, we developed a reaction time paradigm that measures (subjective) colour diagnosticity. In the main experiment, participants adjusted sixteen such objects to their typical colour as well as to grey. If the achromatic object appears in its typical colour, then participants should adjust it to the opponent colour in order to subjectively perceive it as grey. We found that knowledge about the typical colour influences the colour appearance of artificial objects. This effect was particularly strong along the daylight axis.

  8. Object knowledge modulates colour appearance

    PubMed Central

    Witzel, Christoph; Valkova, Hanna; Hansen, Thorsten; Gegenfurtner, Karl R

    2011-01-01

    We investigated the memory colour effect for colour diagnostic artificial objects. Since knowledge about these objects and their colours has been learned in everyday life, these stimuli allow the investigation of the influence of acquired object knowledge on colour appearance. These investigations are relevant for questions about how object and colour information in high-level vision interact as well as for research about the influence of learning and experience on perception in general. In order to identify suitable artificial objects, we developed a reaction time paradigm that measures (subjective) colour diagnosticity. In the main experiment, participants adjusted sixteen such objects to their typical colour as well as to grey. If the achromatic object appears in its typical colour, then participants should adjust it to the opponent colour in order to subjectively perceive it as grey. We found that knowledge about the typical colour influences the colour appearance of artificial objects. This effect was particularly strong along the daylight axis. PMID:23145224

  9. Hypersensitivity reactions to food colours with special reference to the natural colour annatto extract (butter colour).

    PubMed

    Mikkelsen, H; Larsen, J C; Tarding, F

    1978-01-01

    It is well known that synthetic food colours especially some azo dyes can provoke hypersensitivity reactions such as urticaria, angioneurotic oedema, and astma (Michaëlsson and Juhlin, 1973, Granholt and Thune, 1975). Natural food colours are scarcely investigated with respect to potential allergic properties. Annatto extract, a commonly used food colour in edible fats e.g. butter, has been tested in patients. Among 61 consecutive patients suffereing from chornic urticaria and/or angioneurotic oedema 56 patients were orally provoked by annatto extract during elimination diet. Challenge was performed with a dose equivalent to the amount used in 25 grammes of butter. Twentysix per cent of the patients reacted to this colour 4 hours (SD: 2,6) after intake. Similar challenges with synthetic dyes showed the following results: Tartrazine 11%, Sunset Yellow FCF 17%, Food Red 17 16%, Amaranth 9%, Ponceau 4 R 15%, Erythrosine 12% and Brillant Blue FCF 14%. The present study indicates that natural food colours may induce hypersensitivity reactions as frequent as synthetic dyes.

  10. Optimal colour quality of LED clusters based on memory colours.

    PubMed

    Smet, Kevin; Ryckaert, Wouter R; Pointer, Michael R; Deconinck, Geert; Hanselaer, Peter

    2011-03-28

    The spectral power distributions of tri- and tetrachromatic clusters of Light-Emitting-Diodes, composed of simulated and commercially available LEDs, were optimized with a genetic algorithm to maximize the luminous efficacy of radiation and the colour quality as assessed by the memory colour quality metric developed by the authors. The trade-off of the colour quality as assessed by the memory colour metric and the luminous efficacy of radiation was investigated by calculating the Pareto optimal front using the NSGA-II genetic algorithm. Optimal peak wavelengths and spectral widths of the LEDs were derived, and over half of them were found to be close to Thornton's prime colours. The Pareto optimal fronts of real LED clusters were always found to be smaller than those of the simulated clusters. The effect of binning on designing a real LED cluster was investigated and was found to be quite large. Finally, a real LED cluster of commercially available AlGaInP, InGaN and phosphor white LEDs was optimized to obtain a higher score on memory colour quality scale than its corresponding CIE reference illuminant.

  11. Colour Measurements and Modeling

    NASA Astrophysics Data System (ADS)

    Jha, Shyam N.

    The most common property to measure quality of any material is its appearance. Appearance includes colour, shape, size and surface conditions. The analysis of colour is especially an important consideration when determining the efficacy of variety of postharvest treatments. Consumers can easily be influenced by preconceived ideas of how a particular fruit or vegetable or a processed food should appear, and marketers often attempt to improve upon what nature has painted. Recently colour measurements have also been used as quality parameters and indicator of some inner constituents of the material. In spite of the significance of colour in food industries, many continue to analyze it inadequately. This chapter deals with theory of colour, colour scales and its measurement, sampling techniques, and modeling of colour values for correlating them with some internal quality parameters of selected fruits.

  12. Colour categories are reflected in sensory stages of colour perception when stimulus issues are resolved.

    PubMed

    Forder, Lewis; He, Xun; Franklin, Anna

    2017-01-01

    Debate exists about the time course of the effect of colour categories on visual processing. We investigated the effect of colour categories for two groups who differed in whether they categorised a blue-green boundary colour as the same- or different-category to a reliably-named blue colour and a reliably-named green colour. Colour differences were equated in just-noticeable differences to be equally discriminable. We analysed event-related potentials for these colours elicited on a passive visual oddball task and investigated the time course of categorical effects on colour processing. Support for category effects was found 100 ms after stimulus onset, and over frontal sites around 250 ms, suggesting that colour naming affects both early sensory and later stages of chromatic processing.

  13. Colour categories are reflected in sensory stages of colour perception when stimulus issues are resolved

    PubMed Central

    He, Xun; Franklin, Anna

    2017-01-01

    Debate exists about the time course of the effect of colour categories on visual processing. We investigated the effect of colour categories for two groups who differed in whether they categorised a blue-green boundary colour as the same- or different-category to a reliably-named blue colour and a reliably-named green colour. Colour differences were equated in just-noticeable differences to be equally discriminable. We analysed event-related potentials for these colours elicited on a passive visual oddball task and investigated the time course of categorical effects on colour processing. Support for category effects was found 100 ms after stimulus onset, and over frontal sites around 250 ms, suggesting that colour naming affects both early sensory and later stages of chromatic processing. PMID:28542426

  14. Musculoskeletal ultrasonography delineates ankle symptoms in rheumatoid arthritis.

    PubMed

    Toyota, Yukihiro; Tamura, Maasa; Kirino, Yohei; Sugiyama, Yumiko; Tsuchida, Naomi; Kunishita, Yosuke; Kishimoto, Daiga; Kamiyama, Reikou; Miura, Yasushi; Minegishi, Kaoru; Yoshimi, Ryusuke; Ueda, Atsuhisa; Nakajima, Hideaki

    2017-05-01

    To clarify the use of musculoskeletal ultrasonography (US) of ankle joints in rheumatoid arthritis (RA). Consecutive RA patients with or without ankle symptoms participated in the study. The US, clinical examination (CE), and patients' visual analog scale for pain (pVAS) for ankles were assessed. Prevalence of tibiotalar joint synovitis and tenosynovitis were assessed by grayscale (GS) and power Doppler (PD) US using a semi-quantitative grading (0-3). The positive US and CE findings were defined as GS score ≥2 and/or PD score ≥1, and joint swelling and/or tenderness, respectively. Multivariate analysis with the generalized linear mixed model was performed by assigning ankle pVAS as a dependent variable. Among a total of 120 ankles from 60 RA patients, positive ankle US findings were found in 21 (35.0%) patients. The concordance rate of CE and US was moderate (kappa 0.57). Of the 88 CE negative ankles, US detected positive findings in 9 (10.2%) joints. Multivariate analysis revealed that ankle US, clinical disease activity index, and foot Health Assessment Questionnaire, but not CE, was independently associated with ankle pVAS. US examination is useful to illustrate RA ankle involvement, especially for patients who complain ankle pain but lack CE findings.

  15. Use of translabial three-dimensional power Doppler ultrasound for cervical assessment before labor induction.

    PubMed

    Esin, Sertac; Yirci, Bulent; Yalvac, Serdar; Kandemir, Omer

    2017-07-26

    To compare translabial three-dimensional (3D) power Doppler ultrasound with Bishop score and transvaginal ultrasound measurements for cervical assessment before induction of labor with dinoprostone or cervical ripening balloon. Translabial cervical volume and length, vascularization indices and transvaginal cervical length were measured. Results were compared among women who had vaginal delivery at 24 h or less and more than 24 h after the insertion of the dinoprostone vaginal insert or cervical ripening balloon and among women who had vaginal delivery and cesarean delivery for failure to go into labor or failure to progress. There was no correlation between the time to delivery after a ripening agent was applied and translabial cervical volume, translabial cervical length, vascularization index (VI), flow index (FI), vascularization flow index (VFI), transvaginal cervical length and Bishop scores. The ultrasonographic measurements were no different among women who had vaginal delivery at 24 h or less and more than 24 h and among women who had vaginal delivery and cesarean delivery for failure to go into labor or failure to progress. In this study, we failed to demonstrate the superiority of translabial 3D ultrasonography over Bishop score and transvaginal ultrasonography for predicting the success of induction of labor.

  16. Minimum Colour Differences Required To Recognise Small Objects On A Colour CRT

    NASA Astrophysics Data System (ADS)

    Phillips, Peter L.

    1985-05-01

    Data is required to assist in the assessment, evaluation and optimisation of colour and other displays for both military and general use. A general aim is to develop a mathematical technique to aid optimisation and reduce the amount of expensive hardware development and trials necessary when introducing new displays. The present standards and methods available for evaluating colour differences are known not to apply to the perception of typical objects on a display. Data is required for irregular objects viewed at small angular subtense ((1°) and relating the recognition of form rather than colour matching. Therefore laboratory experiments have been carried out using a computer controlled CRT to measure the threshold colour difference that an observer requires between object and background so that he can discriminate a variety of similar objects. Measurements are included for a variety of background and object colourings. The results are presented in the CIE colorimetric system similar to current standards used by the display engineer. Apart from the characteristic small field tritanopia, the results show that larger colour differences are required for object recognition than those assumed from conventional colour discrimination data. A simple relationship to account for object size and background colour is suggested to aid visual performance assessments and modelling.

  17. Doppler ultrasonographic assessment of maternal and fetal arteries during normal feline gestation.

    PubMed

    Blanco, P G; Rodríguez, R; Olguín, S; Rube, A; Tórtora, M; Gobello, C

    2014-04-01

    The aim of this study was to describe Doppler parameters of uterine, umbilical, fetal abdominal aorta, fetal renal and fetal internal carotid arteries, as well as fetal heart rate (FHR), during normal feline gestation. Fifteen, 1-4 years of age, weighing 2.5-3.9kg, domestic short-hair pregnant queens, which were born in our institutional cat colony were included in this study. Color and pulsed-wave Doppler evaluations of uterine arteries were performed every 10 days (Day 0, 10, 20, 30, 40, 50, 60) from mating. Fetal Doppler and M-mode ultrasonography were performed to assess umbilical, fetal abdominal aorta, fetal renal, fetal internal carotid arteries and FHR. Both peak systolic velocity (PSV) and end diastolic velocity (EDV) of uterine artery increased up to parturition (P<0.01), while resistance index (RI) decreased from Day 10 onwards (P<0.01). From Day 40 onwards, RI of umbilical artery diminished, while PSV and EDV augmented (P<0.01). Fetal abdominal aorta (P<0.01), renal (P<0.01) and internal carotid (P<0.01) arteries diminished their RI from Days 40, 60 and 40 onwards, respectively. Both PSV and EDV of these three arteries increased progressively. Fetal heart rate was first registered on Day 20 when it began to increase up to Day 40 and then diminished to the end of gestation (P<0.01). It is concluded that blood flow of uterine, umbilical, fetal abdominal aorta, fetal renal and fetal internal carotid arteries progressively increased during normal feline pregnancy, while FHR rose to mid gestation and then decreased up to parturition. Copyright © 2014 Elsevier B.V. All rights reserved.

  18. Color Doppler quantitative measures to predict outcome of biopsies in prostate cancer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Strigari, Lidia; Marsella, Annelisa; Canitano, Stefano

    2008-11-15

    Purpose: The aim was to correlate the color Doppler flow activity pre- and postradiotherapy, using transrectal color Doppler ultrasonography (CDUS) and the 2 year positive biopsy rate after radiotherapy in patients with prostate cancer. Methods and materials: Analysis was carried out in 69 out of 160 patients who had undergone treatment with 3D-conformal radiotherapy (3D-CRT) to prostate and seminal vesicles. Patients were randomized to receive 80 Gy in 40 fractions in 8 weeks (arm A) and 62 Gy in 20 fractions in 5 weeks, 4 fractions per week (arm B). Color Doppler flow activity (CDFA) was evaluated calculating the vascularizationmore » index (VI), defined as the ratio between the colored and total pixels in the whole and peripheral prostate, delineated by a radiation oncologist on CDUS images, using EcoVasc a home-made software. The difference between the 2 year post- and pre-3D-CRT maximum VI (VI{sub max}), named {Delta}VI{sub max}, was calculated in the whole and peripheral prostate for each patient. Then, {Delta}VI{sub max} and the detected 2 year biopsy outcome were analyzed using the receiver operating characteristics (ROC) technique. Results: The VI{sub max} increased or decreased in patients with positive or negative biopsies, respectively, compared to the value before RT in both arms. The area under the ROC curve for {Delta}VI{sub max} in the whole and peripheral prostate is equal to 0.790 and 0.884, respectively. Conclusion: The {Delta}VI{sub max} index, comparing CDFA at 2 years compared to that before RT, allows the 2 year postradiotherapy positive biopsy rate to be predicted.« less

  19. Put on that colour, it fits your emotion: Colour appropriateness as a function of expressed emotion.

    PubMed

    Dael, Nele; Perseguers, Marie-Noëlle; Marchand, Cynthia; Antonietti, Jean-Philippe; Mohr, Christine

    2016-01-01

    People associate affective meaning with colour, and this may influence decisions about colours. Hue is traditionally considered the most salient descriptor of colour and colour-affect associations, although colour brightness and saturation seem to have particularly strong affective connotations. To test whether colour choices can be driven by emotion, we investigated whether and how colour hue, brightness, and saturation are systematically associated with bodily expressions of positive (joy) and negative (fear) emotions. Twenty-five non-colour-blind participants viewed videos of these expressions and selected for each video the most appropriate colour using colour sliders providing values for hue, brightness, and saturation. The overall colour choices were congruent with the expressed emotion--that is, participants selected brighter and more saturated colours for joy expressions than for fear expressions. Also, colours along the red-yellow spectrum were deemed more appropriate for joy expressions and cyan-bluish hues for fear expressions. The current study adds further support to the role of emotion in colour choices by (a) showing that emotional information is spontaneously used in an unconstrained choice setting, (b) extending to ecologically valid stimuli occurring in everyday encounters (dressed bodies), and (c) suggesting that all colour parameters are likely to be important when processing affective nonverbal person information, though not independently from each other.

  20. Intracardiac Vortex Dynamics by High-Frame-Rate Doppler Vortography-In Vivo Comparison With Vector Flow Mapping and 4-D Flow MRI.

    PubMed

    Faurie, Julia; Baudet, Mathilde; Assi, Kondo Claude; Auger, Dominique; Gilbert, Guillaume; Tournoux, Francois; Garcia, Damien

    2017-02-01

    Recent studies have suggested that intracardiac vortex flow imaging could be of clinical interest to early diagnose the diastolic heart function. Doppler vortography has been introduced as a simple color Doppler method to detect and quantify intraventricular vortices. This method is able to locate a vortex core based on the recognition of an antisymmetric pattern in the Doppler velocity field. Because the heart is a fast-moving organ, high frame rates are needed to decipher the whole blood vortex dynamics during diastole. In this paper, we adapted the vortography method to high-frame-rate echocardiography using circular waves. Time-resolved Doppler vortography was first validated in vitro in an ideal forced vortex. We observed a strong correlation between the core vorticity determined by high-frame-rate vortography and the ground-truth vorticity. Vortography was also tested in vivo in ten healthy volunteers using high-frame-rate duplex ultrasonography. The main vortex that forms during left ventricular filling was tracked during two-three successive cardiac cycles, and its core vorticity was determined at a sampling rate up to 80 duplex images per heartbeat. Three echocardiographic apical views were evaluated. Vortography-derived vorticities were compared with those returned by the 2-D vector flow mapping approach. Comparison with 4-D flow magnetic resonance imaging was also performed in four of the ten volunteers. Strong intermethod agreements were observed when determining the peak vorticity during early filling. It is concluded that high-frame-rate Doppler vortography can accurately investigate the diastolic vortex dynamics.

  1. Normal Doppler velocimetry of renal vasculature in Persian cats.

    PubMed

    Carvalho, Cibele F; Chammas, Maria C

    2011-06-01

    Renal diseases are common in older cats. Decreased renal blood flow may be the first sign of dysfunction and can be evaluated by Doppler ultrasound. But previous studies suggest that the resistive index (RI) has a low sensitivity for detecting renal disease. Doppler waveforms of renal and intrarenal arteries demonstrate decreased blood flow before there are any changes in the RI. The purpose of this study was to evaluate the normal Doppler flowmetrics parameters of renal arteries (RAs), interlobar arteries (IAs) and abdominal aorta (AO) in adult healthy, Persian cats. Twenty-five Persian cats (13 females and 12 males with mean age of 30 months and an age range 12-60 months) with normal clinical examinations and biochemical tests and normal systemic blood pressure were given B-mode ultrasonographies in order to exclude all nephropathies, including polycystic kidney disease. All measurements were performed on both kidneys. Both kidneys (n=50) were examined by color mapping of the renal vasculature. Pulsed Doppler was used to examine both RAs, the IAs at cranial, middle and caudal sites, and the AO. The RI was calculated for all of the vessels. Early systolic acceleration (ESA) of RA and IA was obtained with Doppler spectral analysis. Furthermore, the ratio indices between RA/AO, and IA/RA velocities were calculated. The mean values of peak systolic velocity (PSV) and the diameter for AO were 53.17±13.46 cm/s and 0.38±0.08 cm, respectively. The mean RA diameter for all 50 kidneys was 0.15±0.02 cm. Considering the velocimetric values in both RAs, the mean PSV and RI that were obtained were 41.17±9.40 cm/s and 0.54±0.07. The RA had a mean ESA of 1.12±1.14 m/s(2) and the calculated upper limit of the reference value was 3.40 m/s(2). The mean renal-aortic ratio was 0.828±0.296. The IA showed PSV and RI values of 32.16±9.33 cm/s and 0.52±0.06, respectively. The mean ESA of all IAs was 0.73±0.61 m/s(2). The calculated upper limit of the reference value was 2.0m

  2. Most and Least Preferred Colours Differ According to Object Context: New Insights from an Unrestricted Colour Range

    PubMed Central

    Jonauskaite, Domicele; Mohr, Christine; Antonietti, Jean-Philippe; Spiers, Peter M.; Althaus, Betty; Anil, Selin; Dael, Nele

    2016-01-01

    Humans like some colours and dislike others, but which particular colours and why remains to be understood. Empirical studies on colour preferences generally targeted most preferred colours, but rarely least preferred (disliked) colours. In addition, findings are often based on general colour preferences leaving open the question whether results generalise to specific objects. Here, 88 participants selected the colours they preferred most and least for three context conditions (general, interior walls, t-shirt) using a high-precision colour picker. Participants also indicated whether they associated their colour choice to a valenced object or concept. The chosen colours varied widely between individuals and contexts and so did the reasons for their choices. Consistent patterns also emerged, as most preferred colours in general were more chromatic, while for walls they were lighter and for t-shirts they were darker and less chromatic compared to least preferred colours. This meant that general colour preferences could not explain object specific colour preferences. Measures of the selection process further revealed that, compared to most preferred colours, least preferred colours were chosen more quickly and were less often linked to valenced objects or concepts. The high intra- and inter-individual variability in this and previous reports furthers our understanding that colour preferences are determined by subjective experiences and that most and least preferred colours are not processed equally. PMID:27022909

  3. Most and Least Preferred Colours Differ According to Object Context: New Insights from an Unrestricted Colour Range.

    PubMed

    Jonauskaite, Domicele; Mohr, Christine; Antonietti, Jean-Philippe; Spiers, Peter M; Althaus, Betty; Anil, Selin; Dael, Nele

    2016-01-01

    Humans like some colours and dislike others, but which particular colours and why remains to be understood. Empirical studies on colour preferences generally targeted most preferred colours, but rarely least preferred (disliked) colours. In addition, findings are often based on general colour preferences leaving open the question whether results generalise to specific objects. Here, 88 participants selected the colours they preferred most and least for three context conditions (general, interior walls, t-shirt) using a high-precision colour picker. Participants also indicated whether they associated their colour choice to a valenced object or concept. The chosen colours varied widely between individuals and contexts and so did the reasons for their choices. Consistent patterns also emerged, as most preferred colours in general were more chromatic, while for walls they were lighter and for t-shirts they were darker and less chromatic compared to least preferred colours. This meant that general colour preferences could not explain object specific colour preferences. Measures of the selection process further revealed that, compared to most preferred colours, least preferred colours were chosen more quickly and were less often linked to valenced objects or concepts. The high intra- and inter-individual variability in this and previous reports furthers our understanding that colour preferences are determined by subjective experiences and that most and least preferred colours are not processed equally.

  4. Colour-Temperature Correspondences: When Reactions to Thermal Stimuli Are Influenced by Colour

    PubMed Central

    Ho, Hsin-Ni; Van Doorn, George H.; Kawabe, Takahiro; Watanabe, Junji; Spence, Charles

    2014-01-01

    In our daily lives, information concerning temperature is often provided by means of colour cues, with red typically being associated with warm/hot, and blue with cold. While such correspondences have been known about for many years, they have primarily been studied using subjective report measures. Here we examined this correspondence using two more objective response measures. First, we used the Implicit Association Test (IAT), a test designed to assess the strength of automatic associations between different concepts in a given individual. Second, we used a priming task that involved speeded target discrimination in order to assess whether priming colour or thermal information could invoke the crossmodal association. The results of the IAT confirmed that the association exists at the level of response selection, thus indicating that a participant’s responses to colour or thermal stimuli are influenced by the colour-temperature correspondence. The results of the priming experiment revealed that priming a colour affected thermal discrimination reaction times (RTs), but thermal cues did not influence colour discrimination responses. These results may therefore provide important clues as to the level of processing at which such colour-temperature correspondences are represented. PMID:24618675

  5. Colour-temperature correspondences: when reactions to thermal stimuli are influenced by colour.

    PubMed

    Ho, Hsin-Ni; Van Doorn, George H; Kawabe, Takahiro; Watanabe, Junji; Spence, Charles

    2014-01-01

    In our daily lives, information concerning temperature is often provided by means of colour cues, with red typically being associated with warm/hot, and blue with cold. While such correspondences have been known about for many years, they have primarily been studied using subjective report measures. Here we examined this correspondence using two more objective response measures. First, we used the Implicit Association Test (IAT), a test designed to assess the strength of automatic associations between different concepts in a given individual. Second, we used a priming task that involved speeded target discrimination in order to assess whether priming colour or thermal information could invoke the crossmodal association. The results of the IAT confirmed that the association exists at the level of response selection, thus indicating that a participant's responses to colour or thermal stimuli are influenced by the colour-temperature correspondence. The results of the priming experiment revealed that priming a colour affected thermal discrimination reaction times (RTs), but thermal cues did not influence colour discrimination responses. These results may therefore provide important clues as to the level of processing at which such colour-temperature correspondences are represented.

  6. A brief history of ultrasound in rheumatology: where we were.

    PubMed

    Grassi, Walter; Filippucci, Emilio

    2014-01-01

    Ultrasonography in the '70s was a well-known and widely used method within several medical specialties but not in rheumatology. Initial development of the field was led by radiologists who mainly investigated the potential of ultrasound in the assessment of large joints. In the late '80s, the first studies supporting the role of ultrasound in the detection of soft tissue changes and bone erosions in the hands of patients with rheumatoid arthritis were published. In the '90s, the dramatic improvement of spatial resolution due to the new generation high frequency probes opened up new avenues for the exploration of otherwise undetectable anatomical details. Ultrasound research during this period was enhanced by the growing use of colour Doppler and power Doppler and by the first prototypes of three dimensional ultrasound. Over the last 10 years, the buzz words in ultrasound research in rheumatology have been standardisation, early diagnosis and therapy monitoring.

  7. Colour assortative pairing in a colour polymorphic lizard is independent of population morph diversity

    NASA Astrophysics Data System (ADS)

    Pérez i de Lanuza, Guillem; Font, Enrique; Carretero, Miguel Ángel

    2016-10-01

    Previous work with a colour polymorphic population of Podarcis muralis (Lacertidae) revealed that lizards pair by ventral colour, favouring the same colour (i.e. homomorphic) pairs. Such assortative pairing, which probably results in colour assortative mating, can have consequences for the genetic structure of the population and potentially promote speciation. The population previously studied, located in the Pyrenees, encompasses white, yellow and orange animals, as well as intermediate white-orange and yellow-orange morphs. However, other Pyrenean populations of P. muralis have less ventral colour morphs. Our aim in this study is to test the generality of the assortative colour pairing system, extending our previous analyses to populations with different morph compositions and frequencies. The results show that the assortative pattern of pairing is similar in all the populations analysed and, hence, independent of morph composition and not restricted to pentamorphic populations. This suggests that assortative pairing by colour is a general phenomenon for colour polymorphic populations of P. muralis.

  8. Molluscan shell colour.

    PubMed

    Williams, Suzanne T

    2017-05-01

    The phylum Mollusca is highly speciose, and is the largest phylum in the marine realm. The great majority of molluscs are shelled, including nearly all bivalves, most gastropods and some cephalopods. The fabulous and diverse colours and patterns of molluscan shells are widely recognised and have been appreciated for hundreds of years by collectors and scientists alike. They serve taxonomists as characters that can be used to recognise and distinguish species, however their function for the animal is sometimes less clear and has been the focus of many ecological and evolutionary studies. Despite these studies, almost nothing is known about the evolution of colour in molluscan shells. This review summarises for the first time major findings of disparate studies relevant to the evolution of shell colour in Mollusca and discusses the importance of colour, including the effects of visual and non-visual selection, diet and abiotic factors. I also summarise the evidence for the heritability of shell colour in some taxa and recent efforts to understand the molecular mechanisms underpinning synthesis of shell colours. I describe some of the main shell pigments found in Mollusca (carotenoids, melanin and tetrapyrroles, including porphyrins and bile pigments), and their durability in the fossil record. Finally I suggest that pigments appear to be distributed in a phylogenetically relevant manner and that the synthesis of colour is likely to be energetically costly. © 2016 Cambridge Philosophical Society.

  9. Role of ultrasonography in the management of twin gestation.

    PubMed

    Smith, Jessica; Treadwell, Marjorie C; Berman, Deborah R

    2018-06-01

    Twins represent 1%-2% of all pregnancies, yet continue to account for a disproportionate share of neonatal adverse events including neonatal intensive care admission, morbidity, and mortality. Ultrasonography is central to the proper diagnosis of the type of twinning. Ideally, ultrasonography is performed before 14 weeks of gestation to determine chorionicity and amnionicity. Correct identification of the chorionicity in a twin pregnancy facilitates proper counseling and management of the gestation, including ultrasonography follow-up. Herein, the different types of twinning are reviewed, together with the implications for ultrasonography monitoring of each specific type of twin gestation. © 2018 International Federation of Gynecology and Obstetrics.

  10. Colour for Behavioural Success.

    PubMed

    Dresp-Langley, Birgitta; Reeves, Adam

    2018-01-01

    Colour information not only helps sustain the survival of animal species by guiding sexual selection and foraging behaviour but also is an important factor in the cultural and technological development of our own species. This is illustrated by examples from the visual arts and from state-of-the-art imaging technology, where the strategic use of colour has become a powerful tool for guiding the planning and execution of interventional procedures. The functional role of colour information in terms of its potential benefits to behavioural success across the species is addressed in the introduction here to clarify why colour perception may have evolved to generate behavioural success. It is argued that evolutionary and environmental pressures influence not only colour trait production in the different species but also their ability to process and exploit colour information for goal-specific purposes. We then leap straight to the human primate with insight from current research on the facilitating role of colour cues on performance training with precision technology for image-guided surgical planning and intervention. It is shown that local colour cues in two-dimensional images generated by a surgical fisheye camera help individuals become more precise rapidly across a limited number of trial sets in simulator training for specific manual gestures with a tool. This facilitating effect of a local colour cue on performance evolution in a video-controlled simulator (pick-and-place) task can be explained in terms of colour-based figure-ground segregation facilitating attention to local image parts when more than two layers of subjective surface depth are present, as in all natural and surgical images.

  11. Colour for Behavioural Success

    PubMed Central

    Reeves, Adam

    2018-01-01

    Colour information not only helps sustain the survival of animal species by guiding sexual selection and foraging behaviour but also is an important factor in the cultural and technological development of our own species. This is illustrated by examples from the visual arts and from state-of-the-art imaging technology, where the strategic use of colour has become a powerful tool for guiding the planning and execution of interventional procedures. The functional role of colour information in terms of its potential benefits to behavioural success across the species is addressed in the introduction here to clarify why colour perception may have evolved to generate behavioural success. It is argued that evolutionary and environmental pressures influence not only colour trait production in the different species but also their ability to process and exploit colour information for goal-specific purposes. We then leap straight to the human primate with insight from current research on the facilitating role of colour cues on performance training with precision technology for image-guided surgical planning and intervention. It is shown that local colour cues in two-dimensional images generated by a surgical fisheye camera help individuals become more precise rapidly across a limited number of trial sets in simulator training for specific manual gestures with a tool. This facilitating effect of a local colour cue on performance evolution in a video-controlled simulator (pick-and-place) task can be explained in terms of colour-based figure-ground segregation facilitating attention to local image parts when more than two layers of subjective surface depth are present, as in all natural and surgical images. PMID:29770183

  12. Bumblebees (Bombus terrestris) and honeybees (Apis mellifera) prefer similar colours of higher spectral purity over trained colours.

    PubMed

    Rohde, Katja; Papiorek, Sarah; Lunau, Klaus

    2013-03-01

    Differences in the concentration of pigments as well as their composition and spatial arrangement cause intraspecific variation in the spectral signature of flowers. Known colour preferences and requirements for flower-constant foraging bees predict different responses to colour variability. In experimental settings, we simulated small variations of unicoloured petals and variations in the spatial arrangement of colours within tricoloured petals using artificial flowers and studied their impact on the colour choices of bumblebees and honeybees. Workers were trained to artificial flowers of a given colour and then given the simultaneous choice between three test colours: either the training colour, one colour of lower and one of higher spectral purity, or the training colour, one colour of lower and one of higher dominant wavelength; in all cases the perceptual contrast between the training colour and the additional test colours was similarly small. Bees preferred artificial test flowers which resembled the training colour with the exception that they preferred test colours with higher spectral purity over trained colours. Testing the behaviour of bees at artificial flowers displaying a centripetal or centrifugal arrangement of three equally sized colours with small differences in spectral purity, bees did not prefer any type of artificial flowers, but preferentially choose the most spectrally pure area for the first antenna contact at both types of artificial flowers. Our results indicate that innate preferences for flower colours of high spectral purity in pollinators might exert selective pressure on the evolution of flower colours.

  13. Can single use negative pressure wound therapy be an alternative method to manage keloid scarring? A preliminary report of a clinical and ultrasound/colour-power-doppler study.

    PubMed

    Fraccalvieri, Marco; Sarno, Antonino; Gasperini, Stefano; Zingarelli, Enrico; Fava, Raffaella; Salomone, Marco; Bruschi, Stefano

    2013-06-01

    Keloid scarring represents a pathological healing where primary healing phenomenon is deviated from normal. Pico is a single use negative pressure wound therapy system originally introduced to manage open or just closed wounds. Pico dressing is made of silicone, and distributes an 80 mmHg negative pressure across wound bed. Combination of silicon layer and continuous compression could be a valid method to manage keloid scarring. Since November 2011, three patients were enrolled and evaluated before negative pressure treatment, at end of treatment (1 month) and 2 months later, through Vancouver Scar Scale (VSS), Visual Analog Scale (VAS) and a scoring system for itching. Ultrasound (US) and colour-power-doppler (CPD) examination was performed to evaluate thickness and vascularisation of the scar. One patient was discharged from study after 1 week. In last two patients, VSS, VAS and itching significantly improved after 1 month therapy and the results were stable after 2 months without any therapy. At end of therapy, the 'appearance of palisade vessels' disappeared in both cases at CPD exam; US showed a thickness reduction (average 43·8%). We propose a well-tolerated, non invasive treatment to manage keloid scarring. Prospective studies are necessary to investigate whether these preliminary observations are confirmed. © 2012 The Authors. International Wound Journal © 2012 John Wiley & Sons Ltd and Medicalhelplines.com Inc.

  14. Rheumatoid and psoriatic knee synovitis: clinical, grey scale, and power Doppler ultrasound assessment of the response to etanercept

    PubMed Central

    Fiocco, U; Ferro, F; Vezzu, M; Cozzi, L; Checchetto, C; Sfriso, P; Botsios, C; Ciprian, L; Armellin, G; Nardacchione, R; Piccoli, A; Todesco, S; Rubaltelli, L

    2005-01-01

    Objective: To determine the effect of tumour necrosis factor α (TNFα) blockade with etanercept in refractory knee joint synovitis (KJS) in rheumatoid and psoriatic arthritis, by local and systemic disease activity assessment and combined grey scale and power Doppler ultrasonographic monitoring. Methods: 27 knees affected by rheumatoid KJS (n = 12) and psoriatic KJS (n = 8) were assessed before receiving treatment and at 3 and 12 months' follow up. Time dependent clinical changes in disease activity were monitored by C reactive protein, erythrocyte sedimentation rate (ESR), global health status (GHS), and Ritchie (RAI) and knee joint articular (KJAI) indices; synovial changes were monitored by ultrasonographic and power Doppler indices for grey scale synovial thickening and for distinct intrasynovial vessel power Doppler flow configurations (fluid/synovium interface (F/SI-PD) and pannus/cartilage interface (P/CI-PD)). Interobserver and intraobserver variability of grey scale and power Doppler ultrasonographic was evaluated. Response to treatment was assessed by analysis of variance for repeated measures on clinical and ultrasonographic variables. Results: Rapid (3 months) reduction in F/SI-PD flow (p<0.001), parallel to reductions of C reactive protein (p<0.05), ESR (p<0.001), KJAI (p<0.002), RAI, and GHS (p<0.001), was sustained at 12 months when it was accompanied by reduction in both synovial thickening and P/CI-PD flow (p<0.001). No differences (ANOVA) were noted at baseline or at 12 months in clinical and ultrasonographic variables between either the rheumatoid or the psoriatic KJS groups. Conclusion: Grey scale and power Doppler ultrasonography are reliable measures of long term change in rheumatoid and psoriatic KJS disease activity in response to anti-TNFα treatment with etanercept. PMID:15567814

  15. Dynamic plasmonic colour display

    NASA Astrophysics Data System (ADS)

    Duan, Xiaoyang; Kamin, Simon; Liu, Na

    2017-02-01

    Plasmonic colour printing based on engineered metasurfaces has revolutionized colour display science due to its unprecedented subwavelength resolution and high-density optical data storage. However, advanced plasmonic displays with novel functionalities including dynamic multicolour printing, animations, and highly secure encryption have remained in their infancy. Here we demonstrate a dynamic plasmonic colour display technique that enables all the aforementioned functionalities using catalytic magnesium metasurfaces. Controlled hydrogenation and dehydrogenation of the constituent magnesium nanoparticles, which serve as dynamic pixels, allow for plasmonic colour printing, tuning, erasing and restoration of colour. Different dynamic pixels feature distinct colour transformation kinetics, enabling plasmonic animations. Through smart material processing, information encoded on selected pixels, which are indiscernible to both optical and scanning electron microscopies, can only be read out using hydrogen as a decoding key, suggesting a new generation of information encryption and anti-counterfeiting applications.

  16. Dynamic plasmonic colour display.

    PubMed

    Duan, Xiaoyang; Kamin, Simon; Liu, Na

    2017-02-24

    Plasmonic colour printing based on engineered metasurfaces has revolutionized colour display science due to its unprecedented subwavelength resolution and high-density optical data storage. However, advanced plasmonic displays with novel functionalities including dynamic multicolour printing, animations, and highly secure encryption have remained in their infancy. Here we demonstrate a dynamic plasmonic colour display technique that enables all the aforementioned functionalities using catalytic magnesium metasurfaces. Controlled hydrogenation and dehydrogenation of the constituent magnesium nanoparticles, which serve as dynamic pixels, allow for plasmonic colour printing, tuning, erasing and restoration of colour. Different dynamic pixels feature distinct colour transformation kinetics, enabling plasmonic animations. Through smart material processing, information encoded on selected pixels, which are indiscernible to both optical and scanning electron microscopies, can only be read out using hydrogen as a decoding key, suggesting a new generation of information encryption and anti-counterfeiting applications.

  17. Dynamic plasmonic colour display

    PubMed Central

    Duan, Xiaoyang; Kamin, Simon; Liu, Na

    2017-01-01

    Plasmonic colour printing based on engineered metasurfaces has revolutionized colour display science due to its unprecedented subwavelength resolution and high-density optical data storage. However, advanced plasmonic displays with novel functionalities including dynamic multicolour printing, animations, and highly secure encryption have remained in their infancy. Here we demonstrate a dynamic plasmonic colour display technique that enables all the aforementioned functionalities using catalytic magnesium metasurfaces. Controlled hydrogenation and dehydrogenation of the constituent magnesium nanoparticles, which serve as dynamic pixels, allow for plasmonic colour printing, tuning, erasing and restoration of colour. Different dynamic pixels feature distinct colour transformation kinetics, enabling plasmonic animations. Through smart material processing, information encoded on selected pixels, which are indiscernible to both optical and scanning electron microscopies, can only be read out using hydrogen as a decoding key, suggesting a new generation of information encryption and anti-counterfeiting applications. PMID:28232722

  18. Contrast normalization in colour vision: the effect of luminance contrast on colour contrast detection

    PubMed Central

    Mullen, Kathy T.; Kim, Yeon Jin; Gheiratmand, Mina

    2014-01-01

    While contrast normalization is well known to occur in luminance vision between overlaid achromatic contrasts, and in colour vision between overlaid colour contrasts, it is unknown whether it transfers between colour and luminance contrast. Here we investigate whether contrast detection in colour vision can be normalized by achromatic contrast, or whether this is a selective process driven only by colour contrast. We use a method of cross-orientation masking, in which colour detection is masked by cross-oriented achromatic contrast, over a range of spatio-temporal frequencies (0.375–1.5 cpd, 2–8 Hz). We find that there is virtually no cross-masking of colour by achromatic contrast under monocular or binocular conditions for any of the spatio-temporal frequencies tested, although we find significant facilitation at low spatio-temporal conditions (0.375 cpd, 2 Hz). These results indicate that the process of contrast nornalization is colour selective and independent of achromatic contrast, and imply segregated chromatic signals in early visual processing. Under dichoptic conditions, however, we find a strikingly different result with significant masking of colour by achromatic contrast. This indicates that the dichoptic site of suppression is unselective, responding similarly to colour and luminance contrast, and suggests that dichoptic suppression has a different origin from monocular or binocular suppression. PMID:25491564

  19. Seasonal Changes in Colour: A Comparison of Structural, Melanin- and Carotenoid-Based Plumage Colours

    PubMed Central

    Delhey, Kaspar; Burger, Claudia; Fiedler, Wolfgang; Peters, Anne

    2010-01-01

    Background Plumage coloration is important for bird communication, most notably in sexual signalling. Colour is often considered a good quality indicator, and the expression of exaggerated colours may depend on individual condition during moult. After moult, plumage coloration has been deemed fixed due to the fact that feathers are dead structures. Still, many plumage colours change after moult, although whether this affects signalling has not been sufficiently assessed. Methodology/Principal Findings We studied changes in coloration after moult in four passerine birds (robin, Erithacus rubecula; blackbird, Turdus merula; blue tit, Cyanistes caeruleus; and great tit, Parus major) displaying various coloration types (melanin-, carotenoid-based and structural). Birds were caught regularly during three years to measure plumage reflectance. We used models of avian colour vision to derive two variables, one describing chromatic and the other achromatic variation over the year that can be compared in magnitude among different colour types. All studied plumage patches but one (yellow breast of the blue tit) showed significant chromatic changes over the year, although these were smaller than for a typical dynamic trait (bill colour). Overall, structural colours showed a reduction in relative reflectance at shorter wavelengths, carotenoid-based colours the opposite pattern, while no general pattern was found for melanin-based colours. Achromatic changes were also common, but there were no consistent patterns of change for the different types of colours. Conclusions/Significance Changes of plumage coloration independent of moult are probably widespread; they should be perceivable by birds and have the potential to affect colour signalling. PMID:20644723

  20. The handicap of abnormal colour vision.

    PubMed

    Cole, Barry L

    2004-07-01

    All people with abnormal colour vision, except for a few mildly affected deuteranomals, report that they experience problems with colour in everyday life and at work. Contemporary society presents them with increasing problems because colour is now so widely used in printed materials and in computer displays. Equal opportunity law gives them protection against unfair discrimination in employment, so a decision to exclude a person from employment on the grounds of abnormal colour vision must now be well supported by good evidence and sound argument. This paper reviews the investigations that have contributed to understanding the nature and consequences of the problems they have. All those with abnormal colour vision are at a disadvantage with comparative colour tasks that involve precise matching of colours or discrimination of fine colour differences either because of their loss of colour discrimination or anomalous perception of metamers. The majority have problems when colour is used to code information, in man-made colour codes and in naturally occurring colour codes that signal ripeness of fruit, freshness of meat or illness. They can be denied the benefit of colour to mark out objects and organise complex visual displays. They may be unreliable when a colour name is used as an identifier. They are slower and less successful in search when colour is an attribute of the target object or is used to organise the visual display. Because those with the more severe forms of abnormal colour vision perceive a very limited gamut of colours, they are at a disadvantage in the pursuit and appreciation of those forms of art that use colour.

  1. Specific deficit of colour-colour short-term memory binding in sporadic and familial Alzheimer's disease.

    PubMed

    Parra, Mario A; Sala, Sergio Della; Abrahams, Sharon; Logie, Robert H; Méndez, Luis Guillermo; Lopera, Francisco

    2011-06-01

    Short-term memory binding of visual features which are processed across different dimensions (shape-colour) is impaired in sporadic Alzheimer's disease, familial Alzheimer's disease, and in asymptomatic carriers of familial Alzheimer's disease. This study investigated whether Alzheimer's disease also impacts on within-dimension binding processes. The study specifically explored whether visual short-term memory binding of features of the same type (colour-colour) is sensitive to Alzheimer's disease. We used a neuropsychological battery and a short-term memory binding task to assess patients with sporadic Alzheimer's disease (Experiment 1), familial Alzheimer's disease (Experiment 2) due to the mutation E280A of the Presenilin-1 gene and asymptomatic carriers of the mutation. The binding task assessed change detection within arrays of unicoloured objects (Colour Only) or bicoloured objects the colours of which had to be remembered separately (Unbound Colours) or together (Bound Colours). Performance on the Bound Colours condition (1) explained the largest proportion of variance between patients (sporadic and familial Alzheimer's disease), (2) combined more sensitivity and specificity for the disease than other more traditional neuropsychological tasks, (3) identified asymptomatic carriers of the mutation even when traditional neuropsychological measures and other measures of short-term memory did not and, (4) contrary to shape-colour binding, correlated with measures of hippocampal functions. Colour-colour binding and shape-colour binding both appear to be sensitive to AD even though they seem to rely on different brain mechanisms. Copyright © 2011 Elsevier Ltd. All rights reserved.

  2. Diagnostic value of color doppler ultrasonography in detecting stenosis and occlusion of central veins in patients with chronic kidney disease.

    PubMed

    Rad, Masoud Pezeshki; Kazemzadeh, Gholam Hosain; Ziaee, Masood; Azarkar, Ghodsieh

    2015-03-01

    Venography is an invasive diagnostic test that uses contrast material that provides a picture of the condition of the veins. But, complications, including adverse effects on the kidney, do occur. On the other hand, with the current technological development, application of ultrasound in the diagnosis of obstructive diseases of the veins is gaining popularity, being non-invasive, easy to perform and cost-effective. The aim of this study was to evaluate the diagnostic value of Doppler sonography in the diagnosis of central vein stenosis. In this descriptive-analytical study, 41 hemodialysis patients who had been referred for 50 upper limb venographies to the radiology department of Imam Reza (AS) were included. Patients with chronic kidney disease with a history of catheterization of the vein, jugular or subclavian, and who had established fistulas or synthetic vascular grafts were targeted. Central venous ultrasound was performed on both sides to evaluate stenosis or occlusion. Venography was performed by the radiologist the next day or the day before hemodialysis. Data on demographic characteristics, findings of clinical examination and findings of ultrasound as well as venography were recorded by using the SPSS software, Chi-square test and Spearman correlation, and Kappa agreement was calculated for sensitivity, specificity and predictive values. Twenty-three (56%) patients were male subjects and 18 patients (44%) were female. Twenty-three (56%) patients of the study population were aged <60 years and 18 (43/9%) patients were aged >60 years. The overall sensitivity, specificity and positive predictive value and negative predictive value of Doppler sonography in the proximal veins in hemodialysis patients compared with venography were, respectively, 80.9%, 79.3%, 73.9% and 85.1%. Color Doppler sonography, as a non-invasive method, could be a good alternative for venography in the assessment of the upper limb with central vein stenosis and occlusion.

  3. Colour in digital pathology: a review.

    PubMed

    Clarke, Emily L; Treanor, Darren

    2017-01-01

    Colour is central to the practice of pathology because of the use of coloured histochemical and immunohistochemical stains to visualize tissue features. Our reliance upon histochemical stains and light microscopy has evolved alongside a wide variation in slide colour, with little investigation into the implications of colour variation. However, the introduction of the digital microscope and whole-slide imaging has highlighted the need for further understanding and control of colour. This is because the digitization process itself introduces further colour variation which may affect diagnosis, and image analysis algorithms often use colour or intensity measures to detect or measure tissue features. The US Food and Drug Administration have released recent guidance stating the need to develop a method of controlling colour reproduction throughout the digitization process in whole-slide imaging for primary diagnostic use. This comprehensive review introduces applied basic colour physics and colour interpretation by the human visual system, before discussing the importance of colour in pathology. The process of colour calibration and its application to pathology are also included, as well as a summary of the current guidelines and recommendations regarding colour in digital pathology. © 2016 John Wiley & Sons Ltd.

  4. Automaticity and localisation of concurrents predicts colour area activity in grapheme-colour synaesthesia.

    PubMed

    Gould van Praag, Cassandra D; Garfinkel, Sarah; Ward, Jamie; Bor, Daniel; Seth, Anil K

    2016-07-29

    In grapheme-colour synaesthesia (GCS), the presentation of letters or numbers induces an additional 'concurrent' experience of colour. Early functional MRI (fMRI) investigations of GCS reported activation in colour-selective area V4 during the concurrent experience. However, others have failed to replicate this key finding. We reasoned that individual differences in synaesthetic phenomenology might explain this inconsistency in the literature. To test this hypothesis, we examined fMRI BOLD responses in a group of grapheme-colour synaesthetes (n=20) and matched controls (n=20) while characterising the individual phenomenology of the synaesthetes along dimensions of 'automaticity' and 'localisation'. We used an independent functional localiser to identify colour-selective areas in both groups. Activations in these areas were then assessed during achromatic synaesthesia-inducing, and non-inducing conditions; we also explored whole brain activations, where we sought to replicate the existing literature regarding synaesthesia effects. Controls showed no significant activations in the contrast of inducing > non-inducing synaesthetic stimuli, in colour-selective ROIs or at the whole brain level. In the synaesthete group, we correlated activation within colour-selective ROIs with individual differences in phenomenology using the Coloured Letters and Numbers (CLaN) questionnaire which measures, amongst other attributes, the subjective automaticity/attention in synaesthetic concurrents, and their spatial localisation. Supporting our hypothesis, we found significant correlations between individual measures of synaesthetic phenomenology and BOLD responses in colour-selective areas, when contrasting inducing against non-inducing stimuli. Specifically, left-hemisphere colour area responses were stronger for synaesthetes scoring high on phenomenological localisation and automaticity/attention, while right-hemisphere colour area responses showed a relationship with localisation

  5. Colour-cueing in visual search.

    PubMed

    Laarni, J

    2001-02-01

    Several studies have shown that people can selectively attend to stimulus colour, e.g., in visual search, and that preknowledge of a target colour can improve response speed/accuracy. The purpose was to use a form-identification task to determine whether valid colour precues can produce benefits and invalid cues costs. The subject had to identify the orientation of a "T"-shaped element in a ring of randomly-oriented "L"s when either two or four of the elements were differently coloured. Contrary to Moore and Egeth's (1998) recent findings, colour-based attention did affect performance under data-limited conditions: Colour cues produced benefits when processing load was high; when the load was reduced, they incurred only costs. Surprisingly, a valid colour cue succeeded in improving performance in the high-load condition even when its validity was reduced to the chance level. Overall, the results suggest that knowledge of a target colour does not facilitate the processing of the target, but makes it possible to prioritize it.

  6. Colour fluctuations in grapheme-colour synaesthesia: The effect of clinical and non-clinical mood changes.

    PubMed

    Kay, Collette L; Carmichael, Duncan A; Ruffell, Henry E; Simner, Julia

    2015-08-01

    Synaesthesia is a condition that gives rise to unusual secondary sensations (e.g., colours are perceived when listening to music). These unusual sensations tend to be reported as being stable throughout adulthood (e.g., Simner & Logie, 2007, Neurocase, 13, 358) and the consistency of these experiences over time is taken as the behavioural hallmark of genuineness. Our study looked at the influence of mood states on synaesthetic colours. In Experiment 1, we recruited grapheme-colour synaesthetes (who experience colours from letters/digits) and elicited their synaesthetic colours, as well as their mood and depression states, in two different testing sessions. In each session, participants completed the PANAS-X (Watson & Clark, 1999) and the BDI-II (Beck, Steer, & Brown, 1996, Manual for Beck Depression Inventory-II), and chose their synaesthetic colours for letters A-Z from an interactive colour palette. We found that negative mood significantly decreased the luminance of synaesthetic colours. In Experiment 2, we showed that synaesthetic colours were also less luminant for synaesthetes with anxiety disorder, versus those without. Additional evidence suggests that colour saturation, too, may inversely correlate with depressive symptoms. These results show that fluctuations in mood within both a normal and clinical range influence synaesthetic colours over time. This has implications for our understanding about the longitudinal stability of synaesthetic experiences, and of how mood may interact with the visual (imagery) systems. © 2014 The British Psychological Society.

  7. Robust colour calibration of an imaging system using a colour space transform and advanced regression modelling.

    PubMed

    Jackman, Patrick; Sun, Da-Wen; Elmasry, Gamal

    2012-08-01

    A new algorithm for the conversion of device dependent RGB colour data into device independent L*a*b* colour data without introducing noticeable error has been developed. By combining a linear colour space transform and advanced multiple regression methodologies it was possible to predict L*a*b* colour data with less than 2.2 colour units of error (CIE 1976). By transforming the red, green and blue colour components into new variables that better reflect the structure of the L*a*b* colour space, a low colour calibration error was immediately achieved (ΔE(CAL) = 14.1). Application of a range of regression models on the data further reduced the colour calibration error substantially (multilinear regression ΔE(CAL) = 5.4; response surface ΔE(CAL) = 2.9; PLSR ΔE(CAL) = 2.6; LASSO regression ΔE(CAL) = 2.1). Only the PLSR models deteriorated substantially under cross validation. The algorithm is adaptable and can be easily recalibrated to any working computer vision system. The algorithm was tested on a typical working laboratory computer vision system and delivered only a very marginal loss of colour information ΔE(CAL) = 2.35. Colour features derived on this system were able to safely discriminate between three classes of ham with 100% correct classification whereas colour features measured on a conventional colourimeter were not. Copyright © 2012 Elsevier Ltd. All rights reserved.

  8. Automated colour identification in melanocytic lesions.

    PubMed

    Sabbaghi, S; Aldeen, M; Garnavi, R; Varigos, G; Doliantis, C; Nicolopoulos, J

    2015-08-01

    Colour information plays an important role in classifying skin lesion. However, colour identification by dermatologists can be very subjective, leading to cases of misdiagnosis. Therefore, a computer-assisted system for quantitative colour identification is highly desirable for dermatologists to use. Although numerous colour detection systems have been developed, few studies have focused on imitating the human visual perception of colours in melanoma application. In this paper we propose a new methodology based on QuadTree decomposition technique for automatic colour identification in dermoscopy images. Our approach mimics the human perception of lesion colours. The proposed method is trained on a set of 47 images from NIH dataset and applied to a test set of 190 skin lesions obtained from PH2 dataset. The results of our proposed method are compared with a recently reported colour identification method using the same dataset. The effectiveness of our method in detecting colours in dermoscopy images is vindicated by obtaining approximately 93% accuracy when the CIELab1 colour space is used.

  9. Colour Mixing Based on Daylight

    ERIC Educational Resources Information Center

    Meyn, Jan-Peter

    2008-01-01

    Colour science is based on the sensation of monochromatic light. In contrast to that, surface colours are caused by reflection of wide sections of the daylight spectrum. Non-spectral colours like magenta and purple appear homologous to colours with spectral hue, if the approach of mixing monochromatic light is abandoned. It is shown that a large…

  10. Colour discrimination ellipses in choroideremia.

    PubMed

    Seitz, Immanuel P; Jolly, Jasleen K; Dominik Fischer, M; Simunovic, Matthew P

    2018-04-01

    The purpose of this study was to characterise alterations in colour discrimination in a cohort of patients with choroideremia prior to gene therapy, using a test previously validated for use in patients with retinal dystrophies. We tested 20 eyes of 10 patients with a diagnosis of choroideremia and an age-matched cohort of 10 eyes of 10 normal controls using the "Cambridge Colour Test" (CCT), in which subjects are required to distinguish the gap in a C presented in one of 4 orientations in a Stilling-type array. Colour discrimination was probed along eight axes in the CIE L*u*v* colour space, and the resulting data were plotted in the CIE 1976 chromaticity diagram and fitted with least-squares ellipses. Subsequently, we estimated the achromatic area for each subject by calculating the area of the resultant discrimination ellipse and calculated sensitivity thresholds along relevant colour confusion axes. Colour discrimination-as quantified by log 10 of the ellipse area expressed in square 1/1000th 2 units in CIE 1976-was 2.26 (range 1.82 to 2.67) for normal subjects and 3.85 (range 2.35 to 5.41) for choroideremia patients. There was a statistically significant correlation between both achromatic area and red-green colour discrimination at the CCT and BCVA, and to a lesser degree between blue colour discrimination at the CCT and BCVA. The majority of ellipses in choroideremia were aligned close to the tritan axis, and loss of sensitivity was significantly larger in the tritan direction than in the red-green. The majority of our patients demonstrated greater loss in tritan discrimination than in red-green colour discrimination using the CCT. There was a significant correlation between achromatic area and BCVA. In keeping with our current understanding of the machinery of colour vision, there was a significant correlation between BCVA and colour discrimination thresholds, which was stronger for red-green colour discrimination, than for tritan colour discrimination. We

  11. Influence of detomidine on atrial fibrillation cycle length measured by intracardiac electrogram recording and by colour tissue Doppler imaging in horses.

    PubMed

    Decloedt, A; de Clercq, D; van der Vekens, N; Verheyen, T; Ven, S; van Loon, G

    2016-01-01

    Shortening of atrial fibrillation cycle length (AFCL) is a marker of atrial electrical remodelling due to atrial fibrillation (AF). To investigate the effect of administration of detomidine on AFCL measured invasively from an intra-atrial electrogram (AFCLEGM) and noninvasively by tissue Doppler imaging (AFCLTDI). We hypothesised that detomidine would have no effect on AFCL but would improve the ease of TDI measurements and facilitate noninvasive AFCL determination. Prospective clinical study. Measurements were performed before and after i.v. administration of 7.5 μg/kg bwt detomidine in 33 episodes of AF in 32 horses (582 ± 64 kg bwt, 10 ± 3 years old) referred for electrical cardioversion. The AFCLEGM was measured from a right atrial intracardiac electrogram. The AFCLTDI was measured from atrial colour tissue velocity curves in 5 atrial wall regions. Mean AFCLEGM and AFCLTDI without and with sedation were compared using a repeated-measures linear mixed model with Bonferroni correction for multiple comparisons and calculation of the Bland-Altman mean bias and limits of agreement between AFCLEGM and AFCLTDI. The mean AFCL was significantly increased after sedation, but this increase was very small (mean difference +4 ms). For AFCLTDI measurements, sedation significantly improved the quality of the atrial myocardial velocity curves and the number of AF cycles that could be measured per cardiac cycle. The Bland-Altman bias between AFCLEGM without sedation and AFCLTDI with sedation ranged from -18 to +15 ms depending on wall region. Bland-Altman limits of agreement were similar between AFCLEGM without sedation and AFCLTDI without and with sedation. Therefore, noninvasive AFCLTDI measurements with sedation can be used to estimate the atrial fibrillatory rate. Sedation facilitates noninvasive AFCL measurements but causes a slight increase in AFCL. Noninvasive AFCL measurements can be used as an indicator of atrial electrical remodelling, to study AF

  12. Colour Perception in Ancient World

    NASA Astrophysics Data System (ADS)

    Nesterov, D. I.; Fedorova, M. Yu

    2017-11-01

    How did the human thought form the surrounding color information into the persistent semantic images of a mythological, pseudoscientific and religious nature? The concepts associated with colour perception are suggested. The existence of colour environment does not depend on the human consciousness. The colour culture formation is directly related to the level of the human consciousness development and the possibility to influence the worldview and culture. The colour perception of a person goes through the stages similar to the development of colour vision in a child. Like any development, the colour consciousness has undergone stages of growth and decline, evolution and stagnation. The way of life and difficult conditions for existence made their own adjustments to the development of the human perception of the surrounding world. Wars have been both a powerful engine of progress in all spheres of life and a great destructive force demolishing the already created and preserved heritage. The surrounding world has always been interesting for humans, evoked images and fantasies in the consciousness of ancient people. Unusual and inexplicable natural phenomena spawned numerous legends and myths which was reflected in the ancient art and architecture and, accordingly, in a certain manifestation of colour in the human society. The colour perception of the ancient man, his pragmatic, utilitarian attitude to colour is considered as well as the influence of dependence on external conditions of existence and their reflection in the colour culture of antiquity. “Natural Science” conducts research in the field of the colour nature and their authorial interpretation of the Hellenic period. Several authorial concepts of the ancient world have been considered.

  13. Real-time, high-resolution ultrasonography of the vocal folds--a prospective pilot study in patients before and after thyroidectomy.

    PubMed

    Dedecjus, Marek; Adamczewski, Zbigniew; Brzeziński, Jan; Lewiński, Andrzej

    2010-09-01

    The aim of the study was to evaluate the functionality of vocal folds (VF) by real-time, high-resolution ultrasonography (US) and to correlate the imaged features to results of laryngological examination (LE). The study group comprised 50 patients (41 females and nine males), qualified to thyroidectomy. All the patients had LE and US examination before and 2 days, 2 months, and 3 months after the surgery. We used high-resolution US imaging to identify VFs and, subsequently, a pulsed Doppler and Doppler gate to quantify the tissue displacement velocity in the vibrating VF section. LE revealed unilateral VF paralysis in two patients. VF dysfunction was diagnosed in other four subjects. In simultaneously performed US examination, changes in VF displacement velocity (VFDV) were observed in ten patients. In two subjects, VFDV was below 30 cm/s- patients with VF paralysis, diagnosed in LE. In a further eight cases, we observed VFDV decrease by 50%, comparing to preoperative values. Both US-imaging and LE, performed after the 3-month follow-up, confirmed the transitional character of the above-mentioned pathologies. US imaging of the VFs correlated with LE results, while being a minimally invasive, easily reproducible, and inexpensive method of examining VF functionality. Thanks to many recording options, it may soon become a perfect tool for an early identification of postoperative VF dysfunction with its later monitoring. To our knowledge, it is the first application of US and Doppler gate modes for VFDF quantification; however, an analysis on a larger group of patients is necessary to standardize the technique.

  14. The role of orbital ultrasonography in distinguishing papilledema from pseudopapilledema

    PubMed Central

    Carter, S B; Pistilli, M; Livingston, K G; Gold, D R; Volpe, N J; Shindler, K S; Liu, G T; Tamhankar, M A

    2014-01-01

    Purpose To determine the sensitivity and specificity of orbital ultrasonography in distinguishing papilledema from pseudopapilledema in adult patients. Methods The records of all adult patients referred to the neuro-ophthalmology service who underwent orbital ultrasonography for the evaluation of suspected papilledema were reviewed. The details of history, ophthalmologic examination, and results of ancillary testing including orbital ultrasonography, MRI, and lumbar puncture were recorded. Results of orbital ultrasonography were correlated with the final diagnosis of papilledema or pseudopapilledema on the basis of the clinical impression of the neuro-ophthalmologist. Ultrasound was considered positive when the optic nerve sheath diameter was ≥3.3 mm along with a positive 30° test. Results The sensitivity of orbital ultrasonography for detection of papilledema was 90% (CI: 80.2–99.3%) and the specificity in detecting pseudopapilledema was 79% (CI: 67.7–90.7%). Conclusions Orbital ultrasonography is a rapid and noninvasive test that is highly sensitive, but less specific in differentiating papilledema from pseudopapilledema in adult patients, and can be useful in guiding further management of patients in whom the diagnosis is initially uncertain. PMID:25190532

  15. Dual-Doppler Feasibility Study

    NASA Technical Reports Server (NTRS)

    Huddleston, Lisa L.

    2012-01-01

    When two or more Doppler weather radar systems are monitoring the same region, the Doppler velocities can be combined to form a three-dimensional (3-D) wind vector field thus providing for a more intuitive analysis of the wind field. A real-time display of the 3-D winds can assist forecasters in predicting the onset of convection and severe weather. The data can also be used to initialize local numerical weather prediction models. Two operational Doppler Radar systems are in the vicinity of Kennedy Space Center (KSC) and Cape Canaveral Air Force Station (CCAFS); these systems are operated by the 45th Space Wing (45 SW) and the National Weather Service Melbourne, Fla. (NWS MLB). Dual-Doppler applications were considered by the 45 SW in choosing the site for the new radar. Accordingly, the 45th Weather Squadron (45 WS), NWS MLB and the National Aeronautics and Space Administration tasked the Applied Meteorology Unit (AMU) to investigate the feasibility of establishing dual-Doppler capability using the two existing systems. This study investigated technical, hardware, and software requirements necessary to enable the establishment of a dual-Doppler capability. Review of the available literature pertaining to the dual-Doppler technique and consultation with experts revealed that the physical locations and resulting beam crossing angles of the 45 SW and NWS MLB radars make them ideally suited for a dual-Doppler capability. The dual-Doppler equations were derived to facilitate complete understanding of dual-Doppler synthesis; to determine the technical information requirements; and to determine the components of wind velocity from the equation of continuity and radial velocity data collected by the two Doppler radars. Analysis confirmed the suitability of the existing systems to provide the desired capability. In addition, it is possible that both 45 SW radar data and Terminal Doppler Weather Radar data from Orlando International Airport could be used to alleviate any

  16. Colour-scent associations in a tropical orchid: three colours but two odours.

    PubMed

    Delle-Vedove, Roxane; Juillet, Nicolas; Bessière, Jean-Marie; Grison, Claude; Barthes, Nicolas; Pailler, Thierry; Dormont, Laurent; Schatz, Bertrand

    2011-06-01

    Colour and scent are the major pollinator attractants to flowers, and their production may be linked by shared biosynthetic pathways. Species with polymorphic floral traits are particularly relevant to study the joint evolution of floral traits. We used in this study the tropical orchid Calanthe sylvatica from Réunion Island. Three distinct colour varieties are observed, presenting lilac, white or purple flowers, and named respectively C. sylvaticavar.lilacina (hereafter referred as var. lilacina), C. sylvaticavar. alba (var. alba) and C. sylvatica var. purpurea (var. purpurea). We investigated the composition of the floral scent produced by these colour varieties using the non-invasive SPME technique in the wild. Scent emissions are dominated by aromatic compounds. Nevertheless, the presence of the terpenoid (E)-4,8-dimethylnona-1,3,7-triène (DMNT) is diagnostic of var. purpurea, with the volatile organic compounds (VOC) produced by some individuals containing up to 60% of DMNT. We evidence specific colour-scent associations in C. sylvatica, with two distinct scent profiles in the three colour varieties: the lilacina-like profile containing no or very little DMNT (<2%) and the purpurea-like profile containing DMNT (>2%). Calanthe sylvatica var. alba individuals group with one or the other scent profile independently of their population of origin. We suggest that white-flowered individuals have evolved at least twice, once from var. lilacina and at least once from var. purpurea after the colonisation of la Réunion. White-flowered individuals may have been favoured by the particular pollinator fauna characterising the island. These flowering varieties of C. sylvatica, which display three colours but two scents profiles prove that colour is not always a good indicator of odour and that colour-scent associations may be complex, depending on pollination ecology of the populations concerned. Copyright © 2011 Elsevier Ltd. All rights reserved.

  17. Reversible colour change in Arthropoda.

    PubMed

    Umbers, Kate D L; Fabricant, Scott A; Gawryszewski, Felipe M; Seago, Ainsley E; Herberstein, Marie E

    2014-11-01

    The mechanisms and functions of reversible colour change in arthropods are highly diverse despite, or perhaps due to, the presence of an exoskeleton. Physiological colour changes, which have been recorded in 90 arthropod species, are rapid and are the result of changes in the positioning of microstructures or pigments, or in the refractive index of layers in the integument. By contrast, morphological colour changes, documented in 31 species, involve the anabolism or catabolism of components (e.g. pigments) directly related to the observable colour. In this review we highlight the diversity of mechanisms by which reversible colour change occurs and the evolutionary context and diversity of arthropod taxa in which it has been observed. Further, we discuss the functions of reversible colour change so far proposed, review the limited behavioural and ecological data, and argue that the field requires phylogenetically controlled approaches to understanding the evolution of reversible colour change. Finally, we encourage biologists to explore new model systems for colour change and to engage scientists from other disciplines; continued cross-disciplinary collaboration is the most promising approach to this nexus of biology, physics, and chemistry. © 2014 The Authors. Biological Reviews © 2014 Cambridge Philosophical Society.

  18. TRIDIMENSIONAL DOPPLER ASSESSMENT: A RELIABLE, NON-INVASIVE AND COST-EFFECTIVE METHOD FOR PREOPERATIVE PERFORATOR ASSESSMENT IN DIEP FLAP.

    PubMed

    Dražan, L; Lombardo, G A G

    The preoperative perforator mapping is an important step in autologous breast reconstruction, making the flap raising safer, more predictable and time-saving. Although the Doppler exam has proven to be less accurate in locating perforators compared with colour duplex sonography and CTA, it will probably remain of importance in clinical practice. The aim of this paper is to share some advices on how to perform a Doppler exam in preoperative evaluation of a DIEAp flap, increasing its reliability in location of the perforators. The study was carried-out preoperatively on 26 consecutive patients. For the evaluation of the matching between Doppler Dot and operative finding was used a Cartesian coordinate systemResults: We have marked preoperatively 145 perforators in 26 patients for a total of 52 semi-abdomens. An average of 5.6 vessels per patient were marked. Of these, 80 (55.17%) were found between 0-1 cm, 36 (24.82%) between 1-2 cm and 5 (3.4%) of these more than 2 cm from each other. We had 24 (16.55%) false positives in which there was no correspondence between the signal and the intraoperative finding. Although the Doppler exam may not provide the same anatomic details as the other newer modalities, such as CTA and MRA, the HHD remains a very useful and important tool for autologous reconstruction. We recommend performing this exam in our standardized and reproducible method to improve the reliability..

  19. Colour application on mammography image segmentation

    NASA Astrophysics Data System (ADS)

    Embong, R.; Aziz, N. M. Nik Ab.; Karim, A. H. Abd; Ibrahim, M. R.

    2017-09-01

    The segmentation process is one of the most important steps in image processing and computer vision since it is vital in the initial stage of image analysis. Segmentation of medical images involves complex structures and it requires precise segmentation result which is necessary for clinical diagnosis such as the detection of tumour, oedema, and necrotic tissues. Since mammography images are grayscale, researchers are looking at the effect of colour in the segmentation process of medical images. Colour is known to play a significant role in the perception of object boundaries in non-medical colour images. Processing colour images require handling more data, hence providing a richer description of objects in the scene. Colour images contain ten percent (10%) additional edge information as compared to their grayscale counterparts. Nevertheless, edge detection in colour image is more challenging than grayscale image as colour space is considered as a vector space. In this study, we implemented red, green, yellow, and blue colour maps to grayscale mammography images with the purpose of testing the effect of colours on the segmentation of abnormality regions in the mammography images. We applied the segmentation process using the Fuzzy C-means algorithm and evaluated the percentage of average relative error of area for each colour type. The results showed that all segmentation with the colour map can be done successfully even for blurred and noisy images. Also the size of the area of the abnormality region is reduced when compare to the segmentation area without the colour map. The green colour map segmentation produced the smallest percentage of average relative error (10.009%) while yellow colour map segmentation gave the largest percentage of relative error (11.367%).

  20. Formation of automatic letter-colour associations in non-synaesthetes through likelihood manipulation of letter-colour pairings.

    PubMed

    Kusnir, Flor; Thut, Gregor

    2012-12-01

    Grapheme-colour synaesthesia is a well-characterized phenomenon in which achromatic letters and/or digits automatically and systematically trigger specific colour sensations. Models of its underlying mechanisms diverge on a central question: whether triggered sensations reflect (1) an overdeveloped capacity in normal cross-modal processing (i.e., sharing characteristics with the general population), or rather (2) qualitatively deviant processing (i.e., unique to a few individuals). To test to what extent synaesthesia-like (automatic) letter-colour associations may be learned by non-synaesthetes into adulthood, implied by (1), we developed a learning paradigm that aimed to implicitly train such associations via a visual search task that employed statistical probability learning of specific letter-colour pairs. In contrast to previous synaesthesia-training studies (Cohen Kadosh, Henik, Catena, Walsh, & Fuentes, 2009; Meier & Rothen, 2009), here all participants were naïve as to the end-goal of the experiment (i.e., the formation of letter-colour associations), mimicking the learning conditions of acquired grapheme-colour synaesthesia (Hancock, 2006; Witthoft & Winawer, 2006). In two experiments, we found evidence for significant binding of colours to letters by non-synaesthetes. These newly-formed associations showed synaesthesia-like characteristics, because they correlated in strength with performance on individual synaesthetic Stroop-tasks (experiment 1), and because interference between the learned (associated) colour and the real colour during letter processing depended on their relative positions in colour space (opponent vs. non-opponent colours, experiment 2) suggesting automatic formation on a perceptual rather than conceptual level, analogous to synaesthesia. Although not evoking conscious colour percepts, these learned, synaesthesia-like associations in non-synaesthetes support that common mechanisms may underlie letter-colour associations in synaesthetes

  1. Effect of Ultrasonography on Student Learning of Shoulder Anatomy and Landmarks.

    PubMed

    de Vries, Kristen D; Brown, Rebecca; Mazzie, Joseph; Jung, Min-Kyung; Yao, Sheldon C; Terzella, Michael J

    2018-01-01

    Ultrasonography is becoming more common in clinical use, and it has been shown to have promising results when introduced into medical school curricula. To determine whether the use of ultrasonography as an educational supplement can improve osteopathic medical students' confidence and ability to locate 4 specific shoulder anatomical landmarks: the coracoid process, the transverse process of T1, the long head of the biceps within the bicipital groove, and the supraspinatus tendon. In this randomized controlled study, first-year osteopathic medical students aged 18 years or older were recruited and randomly assigned to a group with exposure (ultrasonography group) or without exposure (control group) to an ultrasonography machine. First, a survey was administered to measure students' baseline knowledge of shoulder anatomy, confidence in palpation skills, and opinion on anatomical landmark identification teaching methods. Next, students were shown presentations on shoulder anatomy and allowed to practice locating and palpating the specified landmarks. Students in the ultrasonography group were also given instruction on the use of ultrasonography. All students were asked to locate each of the 4 specified anatomical landmarks and then given a follow-up survey. A Mann Whitney U test was used to compare the confidence of the students before and after the intervention. A secondary analysis was performed to compare the degree of deviance from the correct position of the specified anatomical landmark between the ultrasonography and control groups. P values less than .05 were considered statistically significant. Sixty-four students participated. Compared with the control group, students in the ultrasonography group had a greater increase in confidence after the session in their ability to locate the coracoid process, bicipital tendon, and supraspinatus tendon (P=.022, P=.029, P=.44, respectively). Students in the ultrasonography group were also able to more accurately palpate

  2. Language use statistics and prototypical grapheme colours predict synaesthetes' and non-synaesthetes' word-colour associations.

    PubMed

    Goodhew, Stephanie C; Kidd, Evan

    2017-02-01

    Synaesthesia is the neuropsychological phenomenon in which individuals experience unusual sensory associations, such as experiencing particular colours in response to particular words. While it was once thought the particular pairings between stimuli were arbitrary and idiosyncratic to particular synaesthetes, there is now growing evidence for a systematic psycholinguistic basis to the associations. Here we sought to assess the explanatory value of quantifiable lexical association measures (via latent semantic analysis; LSA) in the pairings observed between words and colours in synaesthesia. To test this, we had synaesthetes report the particular colours they experienced in response to given concept words, and found that language association between the concept and colour words provided highly reliable predictors of the reported pairings. These results provide convergent evidence for a psycholinguistic basis to synaesthesia, but in a novel way, showing that exposure to particular patterns of associations in language can predict the formation of particular synaesthetic lexical-colour associations. Consistent with previous research, the prototypical synaesthetic colour for the first letter of the word also played a role in shaping the colour for the whole word, and this effect also interacted with language association, such that the effect of the colour for the first letter was stronger as the association between the concept word and the colour word in language increased. Moreover, when a group of non-synaesthetes were asked what colours they associated with the concept words, they produced very similar reports to the synaesthetes that were predicted by both language association and prototypical synaesthetic colour for the first letter of the word. This points to a shared linguistic experience generating the associations for both groups. Copyright © 2016 Elsevier B.V. All rights reserved.

  3. Reproducibility of electronic tooth colour measurements.

    PubMed

    Ratzmann, Anja; Klinke, Thomas; Schwahn, Christian; Treichel, Anja; Gedrange, Tomasz

    2008-10-01

    Clinical methods of investigation, such as tooth colour determination, should be simple, quick and reproducible. The determination of tooth colours usually relies upon manual comparison of a patient's tooth colour with a colour ring. After some days, however, measurement results frequently lack unequivocal reproducibility. This study aimed to examine an electronic method for reliable colour measurement. The colours of the teeth 14 to 24 were determined by three different examiners in 10 subjects using the colour measuring device Shade Inspector. In total, 12 measurements per tooth were taken. Two measurement time points were scheduled to be taken, namely at study onset (T(1)) and after 6 months (T(2)). At either time point, two measurement series per subject were taken by the different examiners at 2-week intervals. The inter-examiner and intra-examiner agreement of the measurement results was assessed. The concordance for lightness and colour intensity (saturation) was represented by the intra-class correlation coefficient. The categorical variable colour shade (hue) was assessed using the kappa statistic. The study results show that tooth colour can be measured independently of the examiner. Good agreement was found between the examiners.

  4. Biomimetic superwettable materials with structural colours.

    PubMed

    Wang, Zelinlan; Guo, Zhiguang

    2017-12-05

    Structural colours and superwettability are of great interest due to their unique characteristics. However, the application of materials with either structural colours or superwettability is limited. Moreover, materials possessing both structural colours and superwettability are crucial for many practical applications. The combination of structural colours and superwettability can result in materials for use various applications, such as in sensors, detectors, bioassays, anti-counterfeiting, and liquid actuators, by controlling surfaces to repel or absorb liquids. Regarding superwettability and structural colours, surface texture and chemical composition are two factors for the construction of materials with superwettable structural colours. This review aims at offering a comprehensive elaboration of the mechanism, recent biomimetic research, and applications of biomimetic superwettable materials with structural colours. Furthermore, this review provides significant insight into the design, fabrication, and application of biomimetic superwettable materials with structural colours.

  5. Properties of colour reference solutions of the European Pharmacopoea in CIE L*a*b* colour space.

    PubMed

    Subert, J; Farsa, O; Gajdosová, Z

    2006-12-01

    The coordinates of CIE L*a*b* uniform colour space have been acquired from the transmitance spectra of colour reference solutions of European Pharmacopoeia (Ph.Eur.). Calculation of colour differences of these solutions from purified water deltaE* gave their values in the range between 0.7 (B9 solution) to 36 (Y1 solution) CIE units. Excluding red colour reference soulutions, deltaE* values did not depend on concentrations of colour compounds linearly. Small deltaE* values founded by the brown and brownish-yellow colour reference solutions of the lowest concentrations can possibly cause some problems of visual examination of the degree of coloration of liquids according to Ph.Eur.

  6. [Diagnostic utility of endoscopic ultrasonography elastography and contrast-enhanced harmonic endoscopic ultrasonography in a patient with type 2 autoimmune pancreatitis].

    PubMed

    Yokode, Masataka; Shiomi, Hideyuki; Itai, Ryosuke; Mikami, Sakae; Yamashita, Yukimasa; Nakano, Ryota; Ezaki, Takeshi; Masuda, Atsuhiro; Zen, Yoh

    2018-01-01

    A referring hospital diagnosed a 57-year-old man with a pancreatic head mass. The initial endoscopic ultrasonography-guided fine needle aspiration (EUS-FNA) was inconclusive because of the small sample size. Endoscopic ultrasonography elastography (EUS-EG) and contrast-enhanced harmonic endoscopic ultrasonography (CE-EUS), conducted at our institute, raised the possibility of mass-forming pancreatitis or autoimmune pancreatitis (AIP). A repeat EUS-FNA revealed inflammatory changes, including a neutrophilic duct injury suggestive of type 2 AIP. The pancreatic lesion responded well to the steroid therapy. The present case suggests that EUS-EG and CE-EUS may be useful for diagnostic exclusion of pancreatic cancers, and the combined use of EUS-EG and CE-EUS, with EUS-FNA, may help characterize inflammatory pancreatic lesions.

  7. Three-dimensional power doppler ultrasound is useful to monitor the response to treatment in a patient with primary papillary serous carcinoma of the peritoneum.

    PubMed

    Su, Jen-Min; Huang, Yu-Fang; Chen, Helen H W; Cheng, Ya-Min; Chou, Cheng-Yang

    2006-05-01

    To date, this is the first report to monitor changes of intratumor vascularization and the response to radiation and Cyberknife therapy in a patient with recurrent primary papillary serous carcinoma of the peritoneum by three dimensional (3D) power Doppler ultrasonography (PDUS). Transvaginal 3D PDUS detected a recurrent presacral tumor with abundant intratumor vascularity. Serial examinations of the tumor volume and serum CA-125 level were studied before, during, and 6 mo after therapy. Meanwhile, the intratumor blood flow was measured and expressed as vascularity indices. All of the tumor volume, intratumor vascularity indices and serum CA-125 level decreased progressively following therapy. A remaining lesion with nearly absent intratumor power Doppler signals suggested a scarring lesion posttreatment. Indeed, CT-guided tissue biopsy confirmed fibrotic change. 3D PDUS is useful to monitor the response to treatments and to differentiate residual tumors from lesions of scarring change posttreatment. It provides more accurate posttreatment information than pelvic computed tomography.

  8. Cardiovascular ultrasonography detection of embolic sources in trauma.

    PubMed

    Saranteas, Theodosios; Mavrogenis, Andreas F; Poularas, John; Kostroglou, Andreas; Mandila, Christina; Panou, Fotios

    2018-06-01

    Venous thromboembolism (deep vein thrombosis and pulmonary embolism) and bone cement implantation syndrome are major sources of embolic events in trauma patients. In these patients, embolic events due to venous thromboembolism and bone cement implantation syndrome have been detected with cardiac and vascular ultrasonography in the emergency setting, during the perioperative period, and in the intensive care unit. This article discusses the ultrasonography modalities and imaging findings of embolic events related to venous thromboembolism and bone cement implantation syndrome. The aim is to present a short review with exceptional illustrations that can enable physicians to identify sources of emboli in trauma patients with cardiovascular ultrasonography. Copyright © 2018 Elsevier Inc. All rights reserved.

  9. The "Human Colour" Crayon: Investigating the Attitudes and Perceptions of Learners Regarding Race and Skin Colour

    ERIC Educational Resources Information Center

    Alexander, Neeske; Costandius, Elmarie

    2017-01-01

    Some coloured and black learners in South Africa use a light orange or pink crayon to represent themselves in art. Many learners name this colour "human colour" or "skin colour". This is troublesome, because it could reflect exclusionary ways of representing race in images and language. This case study, conducted with two…

  10. A Handheld LED Coloured-Light Mixer for Students to Learn Collaboratively the Primary Colours of Light

    ERIC Educational Resources Information Center

    Nopparatjamjomras, Suchai; Chitaree, Ratchapak; Panijpan, Bhinyo

    2009-01-01

    To overcome students' inaccurate prior knowledge on primary additive colours, a coloured-light mixer has been constructed to enable students to observe directly the colours produced and reach the conclusion by themselves that the three primary colours of light are red, green, and blue (NOT red, yellow, and blue). Three closely packed tiny…

  11. [A Multimedia Tutorial to Train Ultrasonography of the Thyroid for Medical Students].

    PubMed

    Ritter, Julia; Wolfram, Maximilian; Schuler, Stefan; Guntinas-Lichius, Orlando

    2017-11-01

    Physicians in education often have poor experience in practice and assessment of ultrasonography on entering their profession, due to a deficiency of training offers during their study of medicine. Hence, a multimedia device for stepwise learning and training ultrasonography of the thyroid was developed. A software for a portable ultrasonography system was used to design a multimedia device for ultrasonography of the thyroid. It allows the user to illustrate texts and pictorial material simultaneously with ultrasound examination in order to compare own findings with examples from a database. The device was evaluated by 8 medical students and compared to a tutor-guided training. A structured, stepwise manual for ultrasonography of the thyroid with a large content of examples in different sectional images was designed for simultaneous reconstruction with the ultrasonography device. The informative content of the device and the replicability of the examination procedure were evaluated positively. Assessment respecting clarity, eligibility for users without experience and learning success was varying. The tutorial to learn and train ultrasonography of the thyroid is an instrument for self-learning and improving practical education in ultrasonography in medical education. In the next version, the manual for the examination will be structured in greater detail. © Georg Thieme Verlag KG Stuttgart · New York.

  12. Colourism: a global adolescent health concern.

    PubMed

    Craddock, Nadia; Dlova, Ncoza; Diedrichs, Phillippa C

    2018-05-08

    Colourism, a form of prejudice and discrimination based solely upon skin colour, stands to jeopardize the physical health, wellbeing and life chances of adolescents of colour, globally. Research shows that adolescents can experience colourism at school and college, in the criminal justice system, at work and in the media they consume. It is therefore unsurprising that adolescents of colour often express a desire for lighter skin tones and/or are dissatisfied with their skin tone. Although research is scarce, some studies include older adolescents in their samples of skin-lightening product users. This is significant as the evidence is clear that the unmonitored use of skin-lightening products can be harmful to physical and psychological health, with evidence linking skin-lightening use to skin damage, kidney failure and depression. Although it is evident that colourism is central to the lives of adolescents of colour, more research is needed concerning the use of skin-lightening products among adolescents. Media literacy and critical race theory offer avenues in helping attenuate the harmful impact of colourism for adolescents of colour.

  13. Consumer exposures to anthocyanins from colour additives, colouring foodstuffs and from natural occurrence in foods.

    PubMed

    Tennant, David R; Klingenberg, Andreas

    2016-06-01

    Anthocyanins are responsible for the red/blue colour of grapes, currants, and other fruits and vegetables. They may also be extracted for use as colour additives (E163) or concentrated for use as colouring foods. Consumer exposures have been assessed using data on natural occurrence, use levels and frequencies from food manufacturers and European food consumption data. Intakes from natural occurrence can be up to 4 mg kg bw(-1) day(-1) at the mean and up to 17 mg kg bw(-1) day(-1) for children who are high level consumers of red/black berries and small fruits. High-level intakes for children from food colour and colouring food applications lie in the range 0.3-6.3 mg kg bw(-1) day(-1) and for adults at 0.6-2.8 mg kg bw(-1) day(-1). Exposures from food colour use and colouring foods separately or combined are therefore lower than those from natural occurrence in foods.

  14. The original colours of fossil beetles

    PubMed Central

    McNamara, Maria E.; Briggs, Derek E. G.; Orr, Patrick J.; Noh, Heeso; Cao, Hui

    2012-01-01

    Structural colours, the most intense, reflective and pure colours in nature, are generated when light is scattered by complex nanostructures. Metallic structural colours are widespread among modern insects and can be preserved in their fossil counterparts, but it is unclear whether the colours have been altered during fossilization, and whether the absence of colours is always real. To resolve these issues, we investigated fossil beetles from five Cenozoic biotas. Metallic colours in these specimens are generated by an epicuticular multi-layer reflector; the fidelity of its preservation correlates with that of other key cuticular ultrastructures. Where these other ultrastructures are well preserved in non-metallic fossil specimens, we can infer that the original cuticle lacked a multi-layer reflector; its absence in the fossil is not a preservational artefact. Reconstructions of the original colours of the fossils based on the structure of the multi-layer reflector show that the preserved colours are offset systematically to longer wavelengths; this probably reflects alteration of the refractive index of the epicuticle during fossilization. These findings will allow the former presence, and original hue, of metallic structural colours to be identified in diverse fossil insects, thus providing critical evidence of the evolution of structural colour in this group. PMID:21957131

  15. The original colours of fossil beetles.

    PubMed

    McNamara, Maria E; Briggs, Derek E G; Orr, Patrick J; Noh, Heeso; Cao, Hui

    2012-03-22

    Structural colours, the most intense, reflective and pure colours in nature, are generated when light is scattered by complex nanostructures. Metallic structural colours are widespread among modern insects and can be preserved in their fossil counterparts, but it is unclear whether the colours have been altered during fossilization, and whether the absence of colours is always real. To resolve these issues, we investigated fossil beetles from five Cenozoic biotas. Metallic colours in these specimens are generated by an epicuticular multi-layer reflector; the fidelity of its preservation correlates with that of other key cuticular ultrastructures. Where these other ultrastructures are well preserved in non-metallic fossil specimens, we can infer that the original cuticle lacked a multi-layer reflector; its absence in the fossil is not a preservational artefact. Reconstructions of the original colours of the fossils based on the structure of the multi-layer reflector show that the preserved colours are offset systematically to longer wavelengths; this probably reflects alteration of the refractive index of the epicuticle during fossilization. These findings will allow the former presence, and original hue, of metallic structural colours to be identified in diverse fossil insects, thus providing critical evidence of the evolution of structural colour in this group.

  16. Printing colour at the optical diffraction limit.

    PubMed

    Kumar, Karthik; Duan, Huigao; Hegde, Ravi S; Koh, Samuel C W; Wei, Jennifer N; Yang, Joel K W

    2012-09-01

    The highest possible resolution for printed colour images is determined by the diffraction limit of visible light. To achieve this limit, individual colour elements (or pixels) with a pitch of 250 nm are required, translating into printed images at a resolution of ∼100,000 dots per inch (d.p.i.). However, methods for dispensing multiple colourants or fabricating structural colour through plasmonic structures have insufficient resolution and limited scalability. Here, we present a non-colourant method that achieves bright-field colour prints with resolutions up to the optical diffraction limit. Colour information is encoded in the dimensional parameters of metal nanostructures, so that tuning their plasmon resonance determines the colours of the individual pixels. Our colour-mapping strategy produces images with both sharp colour changes and fine tonal variations, is amenable to large-volume colour printing via nanoimprint lithography, and could be useful in making microimages for security, steganography, nanoscale optical filters and high-density spectrally encoded optical data storage.

  17. The evolution of colour pattern complexity: selection for conspicuousness favours contrasting within-body colour combinations in lizards.

    PubMed

    Pérez I de Lanuza, G; Font, E

    2016-05-01

    Many animals display complex colour patterns that comprise several adjacent, often contrasting colour patches. Combining patches of complementary colours increases the overall conspicuousness of the complex pattern, enhancing signal detection. Therefore, selection for conspicuousness may act not only on the design of single colour patches, but also on their combination. Contrasting long- and short-wavelength colour patches are located on the ventral and lateral surfaces of many lacertid lizards. As the combination of long- and short-wavelength-based colours generates local chromatic contrast, we hypothesized that selection may favour the co-occurrence of lateral and ventral contrasting patches, resulting in complex colour patterns that maximize the overall conspicuousness of the signal. To test this hypothesis, we performed a comparative phylogenetic study using a categorical colour classification based on spectral data and descriptive information on lacertid coloration collected from the literature. Our results demonstrate that conspicuous ventral (long-wavelength-based) and lateral (short-wavelength-based) colour patches co-occur throughout the lacertid phylogeny more often than expected by chance, especially in the subfamily Lacertini. These results suggest that selection promotes the evolution of the complex pattern rather than the acquisition of a single conspicuous colour patch, possibly due to the increased conspicuousness caused by the combination of colours with contrasting spectral properties. © 2016 European Society For Evolutionary Biology. Journal of Evolutionary Biology © 2016 European Society For Evolutionary Biology.

  18. Seeing red primes tomato: evidence for comparable priming from colour and colour name primes to semantically related word targets.

    PubMed

    Nijboer, Tanja C W; van Zandvoort, Martine J E; de Haan, Edward H F

    2006-12-01

    There is ample evidence that an independent processing stream exists that subserves the perception and appreciation of colour. Neurophysiological research has identified separate brain mechanisms for the processing of wavelength and colour, and neuropsychological studies have revealed selective colour disorders, such as achromatopsia, colour agnosia, and colour anomia. The aim of the present study is to investigate whether the perception of colour may, despite its independent processing, influence other cognitive functions. Specifically, we investigate the possibility that the perception of a colour influences higher order processes such as the activation of semantically related concepts. We designed an associative priming task involving a colour prime (e.g. a red patch or the word RED) and a lexical decision response to a semantically related ('tomato' vs. 'timato') or unrelated ('grass' vs. 'griss') word target. The results of this experiment indicate that there is comparable facilitation of accessing colour-related semantics through the perception of a colour or the reading of a colour name. This suggests that colour has a direct effect on higher order level, cognitive processing. These results are discussed in terms of current models of colour processing.

  19. An RGB approach to prismatic colours

    NASA Astrophysics Data System (ADS)

    Theilmann, Florian; Grusche, Sascha

    2013-11-01

    Teaching prismatic colours usually boils down to establishing the take-home message that white light consists of ‘differently refrangible’ coloured rays. This approach explains the classical spectrum of seven colours but has its limitations, e.g. in discussing spectra from setups with higher resolution or in understanding the well saturated colours of simple edge spectra. Besides, the connection of physical wavelength and colour remains obscure—after all, colour and wavelength are not equivalent. In this paper, we suggest that teachers demonstrate these impressive experiments in the classroom by using a video projector and a prism to disperse black-and-white slit images. We introduce experimental and diagrammatic methods for establishing the connection between the original slit image and the wavelength composition of the resulting spectrum. From this (or any other given) wavelength composition, students can systematically derive the colours with a simple RGB approach, thus gaining a more accurate picture of the relation between wavelength and colour.

  20. Ultrasonography of the hand, wrist, and elbow.

    PubMed

    Bodor, Marko; Fullerton, Brad

    2010-08-01

    High-frequency diagnostic ultrasonography of the hand, wrist and elbow has significant potential to improve the quality of diagnosis and care provided by neuromuscular and musculoskeletal specialists. In patients referred for weakness, pain and numbness of the hand, wrist or elbow, diagnostic ultrasonography can be an adjunct to electrodiagnosis and help in identifying ruptured tendons and treating conditions such as carpal tunnel syndrome or trigger finger. Use of a small high-frequency (>10-15 MHz) transducer, an instrument with a blunt pointed tip to enhance sonopalpation and a model of the hand, wrist and elbow is advised to enhance visualization of small anatomical structures and complex bony contours. A range of conditions, including tendon and ligament ruptures, trigger finger, de Quervain tenosynovitis, intersection syndrome, lateral epicondylitis, and osteoarthritis, is described along with detailed ultrasonography-guided injection techniques for carpal tunnel syndrome and trigger finger. Copyright 2010 Elsevier Inc. All rights reserved.

  1. Discrepancies between descriptions and illustrations of colours in Congo red-stained amyloid, and explanation of discrepant colours.

    PubMed

    Howie, Alexander J; Owen-Casey, Mared P

    2010-09-01

    Congo red-stained sections of amyloid may show various colours between crossed polariser and analyser. The aims were to see how papers described the colours, to compare descriptions with illustrations, and to explain the colours. In 160 papers on Congo red-stained amyloid, the commonest descriptions were 'green birefringence' and 'apple-green birefringence'. In 191 figures in 82 papers, 59 (31%) showed a pure green colour, 62 (32%) showed green and yellow or blue and yellow, 38 (20%) showed green and a colour other than yellow, mostly red, and 32 (17%) showed other colours. Discrepancies between colours reported and illustrated were noted in 127 figures (66%). Most (77) were between green alone in descriptions and green and another colour in figures, and 30 were between green in descriptions and no green at all in figures. Pure green can be seen in ideal conditions, but more often there are green and yellow, explained by strain birefringence, and green and red or other combinations, explained by uncrossing of polariser and analyser. These other anomalous colours are just as characteristic of amyloid as the pure green colour. Many papers on Congo red-stained amyloid appear to describe what is expected theoretically rather than what is actually seen.

  2. Colour Doppler ultrasound in preoperative assessment of the neck vessels in patients with tumours of the oral cavity and the neck region.

    PubMed

    Falkowski, Aleksander; Wilk, Grazyna; Mokrzyński, Stanisław; Dul, Przemysław; Toloczko-Grabarek, Aleksandra; Huzarski, Tomasz; Kowalczyk, Robert

    2004-06-01

    The aim of the study was not only to establish the applicability of color Doppler ultrasound of the neck vessels in patients with tumors of the oral cavity and the neck region but also to check whether the coexistence of sclerotic changes in the carotid arteries is essential in determination of the sequence of surgical procedure. Color Doppler ultrasound was performed on 110 patients, aged 15 -71 years with tumors of the oral cavity and the neck. The localization, size, echogenicity, as well as the tumor relationship to the surrounding structures and big vessels of the neck region was analyzed. Compression of the veins was observed in 27 cases, and of the arteries only in 20 cases. Infiltration of the jugular vein was observed in 8 patients, whereas infiltration of the carotid artery were seen only in 6 patients. Severe internal carotid artery stenosis, due to arteriosclerosis, was observed in 10 patients. Three persons were suggested to be operated on, first due to carotid artery stenosis, later on, due to the oral cavity tumor. It was found that color Doppler ultrasound is useful in deciding upon the method of treatment, while the examination of the neck vessels is helpful in establishing the sequence of surgical procedures in patients with tumors and coexisting arteriosclerosis.

  3. Colour correct: the interactive effects of food label nutrition colouring schemes and food category healthiness on health perceptions.

    PubMed

    Nyilasy, Gergely; Lei, Jing; Nagpal, Anish; Tan, Joseph

    2016-08-01

    The purpose of the present study was to examine the effects of food label nutrition colouring schemes in interaction with food category healthiness on consumers' perceptions of food healthiness. Three streams of colour theory (colour attention, colour association and colour approach-avoidance) in interaction with heuristic processing theory provide consonant predictions and explanations for the underlying psychological processes. A 2 (food category healthiness: healthy v. unhealthy)×3 (food label nutrient colouring schemes: healthy=green, unhealthy=red (HGUR) v. healthy=red, unhealthy=green (HRUG) v. no colour (control)) between-subjects design was used. The research setting was a randomised-controlled experiment using varying formats of food packages and nutritional information colouring. Respondents (n 196) sourced from a national consumer panel, USA. The findings suggest that, for healthy foods, the nutritional colouring schemes reduced perceived healthiness, irrespective of which nutrients were coloured red or green (healthinesscontrol=4·86; healthinessHGUR=4·10; healthinessHRUG=3·70). In contrast, for unhealthy foods, there was no significant difference in perceptions of food healthiness when comparing different colouring schemes against the control. The results make an important qualification to the common belief that colour coding can enhance the correct interpretation of nutrition information and suggest that this incentive may not necessarily support healthier food choices in all situations.

  4. Colour is more than hue: preferences for compiled colour traits in the stingless bees Melipona mondury and M. quadrifasciata.

    PubMed

    Koethe, Sebastian; Bossems, Jessica; Dyer, Adrian G; Lunau, Klaus

    2016-10-01

    The colour vision of bees has been extensively analysed in honeybees and bumblebees, but few studies consider the visual perception of stingless bees (Meliponini). In a five-stage experiment the preference for colour intensity and purity, and the preference for the dominant wavelength were tested by presenting four colour stimuli in each test to freely flying experienced workers of two stingless bee species, Melipona mondury and Melipona quadrifasciata. The results with bee-blue, bee-UV-blue and bee-green colours offered in four combinations of varying colour intensity and purity suggest a complex interaction between these colour traits for the determination of colour choice. Specifically, M. mondury preferred bee-UV-blue colours over bee-green, bee-blue and bee-blue-green colours while M. quadrifasciata preferred bee-green colour stimuli. Moreover in M. mondury the preferences were different if the background colour was changed from grey to green. There was a significant difference between species where M. mondury preferred UV-reflecting over UV-absorbing bee-blue-green colour stimuli, whereas M. quadrifasciata showed an opposite preference. The different colour preferences of the free flying bees in identical conditions may be caused by the bees' experience with natural flowers precedent to the choice tests, suggesting reward partitioning between species.

  5. Testing the AUDI2000 colour-difference formula for solid colours using some visual datasets with usefulness to automotive industry

    NASA Astrophysics Data System (ADS)

    Martínez-García, Juan; Melgosa, Manuel; Gómez-Robledo, Luis; Li, Changjun; Huang, Min; Liu, Haoxue; Cui, Guihua; Luo, M. Ronnier; Dauser, Thomas

    2013-11-01

    Colour-difference formulas are tools employed in colour industries for objective pass/fail decisions of manufactured products. These objective decisions are based on instrumental colour measurements which must reliably predict the subjective colour-difference evaluations performed by observers' panels. In a previous paper we have tested the performance of different colour-difference formulas using the datasets employed at the development of the last CIErecommended colour-difference formula CIEDE2000, and we found that the AUDI2000 colour-difference formula for solid (homogeneous) colours performed reasonably well, despite the colour pairs in these datasets were not similar to those typically employed in the automotive industry (CIE Publication x038:2013, 465-469). Here we have tested again AUDI2000 together with 11 advanced colour-difference formulas (CIELUV, CIELAB, CMC, BFD, CIE94, CIEDE2000, CAM02-UCS, CAM02-SCD, DIN99d, DIN99b, OSA-GP-Euclidean) for three visual datasets we may consider particularly useful to the automotive industry because of different reasons: 1) 828 metallic colour pairs used to develop the highly reliable RIT-DuPont dataset (Color Res. Appl. 35, 274-283, 2010); 2) printed samples conforming 893 colour pairs with threshold colour differences (J. Opt. Soc. Am. A 29, 883-891, 2012); 3) 150 colour pairs in a tolerance dataset proposed by AUDI. To measure the relative merits of the different tested colour-difference formulas, we employed the STRESS index (J. Opt. Soc. Am. A 24, 1823-1829, 2007), assuming a 95% confidence level. For datasets 1) and 2), AUDI2000 was in the group of the best colour-difference formulas with no significant differences with respect to CIE94, CIEDE2000, CAM02-UCS, DIN99b and DIN99d formulas. For dataset 3) AUDI2000 provided the best results, being statistically significantly better than all other tested colour-difference formulas.

  6. Pollinators show flower colour preferences but flowers with similar colours do not attract similar pollinators

    PubMed Central

    Reverté, Sara; Retana, Javier; Gómez, José M.; Bosch, Jordi

    2016-01-01

    Background and aims Colour is one of the main floral traits used by pollinators to locate flowers. Although pollinators show innate colour preferences, the view that the colour of a flower may be considered an important predictor of its main pollinators is highly controversial because flower choice is highly context-dependent, and initial innate preferences may be overridden by subsequent associative learning. Our objective is to establish whether there is a relationship between flower colour and pollinator composition in natural communities. Methods We measured the flower reflectance spectrum and pollinator composition in four plant communities (85 plant species represented by 109 populations, and 32 305 plant–pollinator interactions in total). Pollinators were divided into six taxonomic groups: bees, ants, wasps, coleopterans, dipterans and lepidopterans. Key Results We found consistent associations between pollinator groups and certain colours. These associations matched innate preferences experimentally established for several pollinators and predictions of the pollination syndrome theory. However, flowers with similar colours did not attract similar pollinator assemblages. Conclusions The explanation for this paradoxical result is that most flower species are pollination generalists. We conclude that although pollinator colour preferences seem to condition plant–pollinator interactions, the selective force behind these preferences has not been strong enough to mediate the appearance and maintenance of tight colour-based plant–pollinator associations. PMID:27325897

  7. The Cognitive Doppler.

    ERIC Educational Resources Information Center

    Kozoil, Micah E.

    1989-01-01

    Discusses the learning needs of students in the concrete operational stage in mathematics. Identifies the phenomenon of reduced cognitive performance in an out-of-class environment as the "Cognitive Doppler." Suggests methods of reducing the pronounced effects of the Cognitive Doppler by capitalizing on the students' ability to memorize…

  8. The control of attentional target selection in a colour/colour conjunction task.

    PubMed

    Berggren, Nick; Eimer, Martin

    2016-11-01

    To investigate the time course of attentional object selection processes in visual search tasks where targets are defined by a combination of features from the same dimension, we measured the N2pc component as an electrophysiological marker of attentional object selection during colour/colour conjunction search. In Experiment 1, participants searched for targets defined by a combination of two colours, while ignoring distractor objects that matched only one of these colours. Reliable N2pc components were triggered by targets and also by partially matching distractors, even when these distractors were accompanied by a target in the same display. The target N2pc was initially equal in size to the sum of the two N2pc components to the two different types of partially matching distractors and became superadditive from approximately 250 ms after search display onset. Experiment 2 demonstrated that the superadditivity of the target N2pc was not due to a selective disengagement of attention from task-irrelevant partially matching distractors. These results indicate that attention was initially deployed separately and in parallel to all target-matching colours, before attentional allocation processes became sensitive to the presence of both matching colours within the same object. They suggest that attention can be controlled simultaneously and independently by multiple features from the same dimension and that feature-guided attentional selection processes operate in parallel for different target-matching objects in the visual field.

  9. Assessment of total placenta previa by magnetic resonance imaging and ultrasonography to detect placenta accreta and its variants.

    PubMed

    Peker, Nuri; Turan, Volkan; Ergenoglu, Mete; Yeniel, Ozgur; Sever, Ahmet; Kazandi, Mert; Zekioglu, Osman

    2013-03-01

    To evaluate the importance of ultrasonography (US) and magnetic resonance imaging (MRI) in detecting placental adherence defects. Patients diagnozed with total placenta previa (n = 40) in whom hysterectomy was performed due to placental adherence defects (n = 20) or in whom the placenta detached spontaneously after a Cesarean delivery (n = 20) were included into the study between June 2008 and January 2011, at the Department of Obstetrics and Gynecology Ege University (lzmir Turkey). Gray-scale US was used to check for any placental lacunae, sub-placental sonolucent spaces or a placental mass invading the vesicouterine plane and bladder Intra-placental lacunar turbulent blood flow and an increase in vascularization in the vesicouterine plane were evaluated with color Doppler mode. Subsequently all patients had MRI and the results were compared with the histopathologic examinations. The sensitivity of MRI for diagnosis of placental adherence defects before the operation was 95%, with a specificity of 95%. In the presence of at least one diagnostic criterion, the sensitivity and specificity of US were 87.5% and 100% respectively, while the sensitivity of color Doppler US was 62.5% with a specificity of 100%. Currently MRI appears to be the gold standard for the diagnosis of placenta accreta. None of the ultrasonographic criteria is solely sufficient to diagnose placental adherence defects, however they assist in the diagnostic process.

  10. Real-time, high-resolution ultrasonography of the vocal folds—a prospective pilot study in patients before and after thyroidectomy

    PubMed Central

    Adamczewski, Zbigniew; Brzeziński, Jan; Lewiński, Andrzej

    2010-01-01

    Purpose The aim of the study was to evaluate the functionality of vocal folds (VF) by real-time, high-resolution ultrasonography (US) and to correlate the imaged features to results of laryngological examination (LE). Methods The study group comprised 50 patients (41 females and nine males), qualified to thyroidectomy. All the patients had LE and US examination before and 2 days, 2 months, and 3 months after the surgery. We used high-resolution US imaging to identify VFs and, subsequently, a pulsed Doppler and Doppler gate to quantify the tissue displacement velocity in the vibrating VF section. Results LE revealed unilateral VF paralysis in two patients. VF dysfunction was diagnosed in other four subjects. In simultaneously performed US examination, changes in VF displacement velocity (VFDV) were observed in ten patients. In two subjects, VFDV was below 30 cm/s— patients with VF paralysis, diagnosed in LE. In a further eight cases, we observed VFDV decrease by 50%, comparing to preoperative values. Both US-imaging and LE, performed after the 3-month follow-up, confirmed the transitional character of the above-mentioned pathologies. Conclusions US imaging of the VFs correlated with LE results, while being a minimally invasive, easily reproducible, and inexpensive method of examining VF functionality. Thanks to many recording options, it may soon become a perfect tool for an early identification of postoperative VF dysfunction with its later monitoring. To our knowledge, it is the first application of US and Doppler gate modes for VFDF quantification; however, an analysis on a larger group of patients is necessary to standardize the technique. PMID:20640934

  11. Survival Rate without Brain Abnormalities on Postnatal Ultrasonography among Monochorionic Twins after Fetoscopic Laser Photocoagulation for Selective Intrauterine Growth Restriction with Concomitant Oligohydramnios.

    PubMed

    Ishii, Keisuke; Wada, Seiji; Takano, Mayumi; Nakata, Masahiko; Murakoshi, Takeshi; Sago, Haruhiko

    2018-02-20

    We aimed to clarify the survival rate without brain abnormalities (BA) after fetoscopic laser photoco-agulation (FLP) for monochorionic diamniotic twin gestations (MCDA) with selective intrauterine growth restriction (sIUGR) accompanied by abnormal umbilical artery (UA) Doppler waveforms and isolated oligohydramnios in the sIUGR twin. This retrospective study included 52 cases that underwent FLP. The main outcome was survival rate without BA of the twins at age 28 days. BA was defined as severe intraventricular hemorrhage and periventricular leukomalacia on postnatal ultrasonography. Median gestational age at FLP was 20 (16-24) weeks. Ten cases were classified as type III based on Doppler for the UA. For all cases, including 20 cases of anterior placenta, FLP was completed without major intraoperative complications. Amnioinfusion was required in 49 cases for better fetoscopic visualization. Fetal loss occurred in 29 sIUGR twins and two larger twins, whereas one larger twin experienced neonatal death. Survival rates without BA were 44% (n = 23) for sIUGR twins and 94% (n = 49) for the larger twins. FLP for MCDA with sIUGR presenting with oligohydramnios in the sIUGR twin might be considered a prenatal treatment option. © 2018 S. Karger AG, Basel.

  12. [Analysis of eye ultrasonography in patients with trinitrotoluene cataract].

    PubMed

    Huang, Dongmei; Zhu, Linping; Yang, Jinping; Wu, Donping

    2015-04-01

    To evaluate the diagnostic value of ultrasonography for trinitrotoluene (TNT) cataract. The morphology and internal echoes of 90 lenses of 45 TNT cataract patients and 120 lenses of 60 healthy adults were observed and compared using ultrasonography and slit lamp, and the hemodynamic parameters of the post-ophthalmic artery were also measured. The findings of the slit-lamp microscope were regarded as diagnostic criteria, and the sensitivity, specificity, and accordance rate of ultrasonography in the diagnosis of TNT cataract were calculated. The sensitivity, specificity, and accordance rate of ultrasonography in the diagnosis of TNT cataract were 93.33%, 100.00%, and 97.14%, respectively; the positive and negative predictive values were 100% and 95.23%, respectively; the positive and negative likelihood ratios were 93.33 and 0.67, especuvey. With the progression TNT cataract, utrasonography showed that the lenses demonstrated morphological changes (spindle-shaped, spherical, and discoid morphologies), and the arc echoes of the posterior capsule were thickened and enhanced. The TNT cataract patients showed significantly lower peak systolic velocity and end-diastolic velocity of the ophthalmic artery (OA) and central retinal artery (P<0.01) and a significantly higher resistance index (P<0.05) than the healthy adults. The sensitivity of ultrasonography in the diagnosis of TNT cataract is similar to that of slit lamp. Ultrasonography can demonstrate objectively the shape, range, and degree of lens opacity in an efficient manner, which is conducive to the diagnosis and staging of TNT cataract by slit lamp, and can also provide hemodynamic information of the OA, thus providing new ideas for clinical physicians in evaluating the disease and clinical efficacy as well as exploring therapies.

  13. Ultrasonography in diagnosing chronic pancreatitis: New aspects

    PubMed Central

    Dimcevski, Georg; Erchinger, Friedemann G; Havre, Roald; Gilja, Odd Helge

    2013-01-01

    The course and outcome is poor for most patients with pancreatic diseases. Advances in pancreatic imaging are important in the detection of pancreatic diseases at early stages. Ultrasonography as a diagnostic tool has made, virtually speaking a technical revolution in medical imaging in the new millennium. It has not only become the preferred method for first line imaging, but also, increasingly to clarify the interpretation of other imaging modalities to obtain efficient clinical decision. We review ultrasonography modalities, focusing on advanced pancreatic imaging and its potential to substantially improve diagnosis of pancreatic diseases at earlier stages. In the first section, we describe scanning techniques and examination protocols. Their consequences for image quality and the ability to obtain complete and detailed visualization of the pancreas are discussed. In the second section we outline ultrasonographic characteristics of pancreatic diseases with emphasis on chronic pancreatitis. Finally, new developments in ultrasonography of the pancreas such as contrast enhanced ultrasound and elastography are enlightened. PMID:24259955

  14. Colorimetry and prime colours--a theorem.

    PubMed

    Hornaes, Hans Petter; Wold, Jan Henrik; Farup, Ivar

    2005-08-01

    Human colour vision is the result of a complex process involving topics ranging from physics of light to perception. Whereas the diversity of light entering the eye in principle span an infinite-dimensional vector space in terms of the spectral power distributions, the space of human colour perceptions is three dimensional. One important consequence of this is that a variety of colours can be visually matched by a mixture of only three adequately chosen reference lights. It has been observed that there exists one particular set of monochromatic reference lights that, according to a certain definition, is optimal for producing colour matches. These reference lights are commonly denoted prime colours. In the present paper, we intend to rigorously show that the existence of prime colours is not particular to the human visual system as sometimes stated, but rather an algebraic consequence of the manner in which a kind of colorimetric functions called colour-matching functions are defined and transformed. The solution is based on maximisation of a determinant determining the gamut size of the colour space spanned by the prime colours. Cramer's rule for solving a set of linear equations is an essential part of the proof. By means of examples, it is shown that mathematically the optimal set of reference lights is not unique in general, and that the existence of a maximum determinant is not a necessary condition for the existence of prime colours.

  15. Doppler flowmetry in preeclampsia.

    PubMed

    Zahumensky, J

    2009-01-01

    The purpose of this study was to summarize the new published data on the Doppler flowmetry in preeclampsia. We summarize the new published data on the Doppler flowmetry in uteroplacental, fetoplacental and fetal circulation in preeclampsia. The present review summarized the results of clinical research on the Doppler flowmetry in the screening of risk of preclampsia, in the diagnosis of preclampsia and in the fetal risk in preclampsia (Ref. 19). Full Text (Free, PDF) www.bmj.sk.

  16. Pollinators show flower colour preferences but flowers with similar colours do not attract similar pollinators.

    PubMed

    Reverté, Sara; Retana, Javier; Gómez, José M; Bosch, Jordi

    2016-08-01

    Colour is one of the main floral traits used by pollinators to locate flowers. Although pollinators show innate colour preferences, the view that the colour of a flower may be considered an important predictor of its main pollinators is highly controversial because flower choice is highly context-dependent, and initial innate preferences may be overridden by subsequent associative learning. Our objective is to establish whether there is a relationship between flower colour and pollinator composition in natural communities. We measured the flower reflectance spectrum and pollinator composition in four plant communities (85 plant species represented by 109 populations, and 32 305 plant-pollinator interactions in total). Pollinators were divided into six taxonomic groups: bees, ants, wasps, coleopterans, dipterans and lepidopterans. We found consistent associations between pollinator groups and certain colours. These associations matched innate preferences experimentally established for several pollinators and predictions of the pollination syndrome theory. However, flowers with similar colours did not attract similar pollinator assemblages. The explanation for this paradoxical result is that most flower species are pollination generalists. We conclude that although pollinator colour preferences seem to condition plant-pollinator interactions, the selective force behind these preferences has not been strong enough to mediate the appearance and maintenance of tight colour-based plant-pollinator associations. © The Author 2016. Published by Oxford University Press on behalf of the Annals of Botany Company. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  17. Immersion ultrasonography: simultaneous A-scan and B-scan.

    PubMed

    Coleman, D J; Dallow, R L; Smith, M E

    1979-01-01

    In eyes with opaque media, ophthalmic ultrasound provides a unique source of information that can dramatically affect the course of patient management. In addition, when an ocular abnormality can be visualized, ultrasonography provides information that supplements and complements other diagnostic testing. It provides documentation and differentiation of abnormal states, such as vitreous hemorrhage and intraocular tumor, as well as differentiation of orbital tumors from inflammatory causes of exophthalmos. Additional capabilities of ultrasound are biometric determinations for calculation of intraocular lens implant powers and drug-effectiveness studies. Maximal information is derived from ultrasonography when A-scan and B-scan techniques are employed simultaneously. Flexibility of electronics, variable-frequency transducers, and the use of several different manual scanning patterns aid in detection and interpretation of results. The immersion system of ultrasonography provides these features optimally.

  18. The unsuitability of HTML-based colour charts for estimating animal colours--a comment on Berggren and Merilä (2004).

    PubMed

    Stevens, Martin; Cuthill, Innes C

    2005-08-30

    A variety of techniques are used to study the colours of animal signals, including the use of visual matching to colour charts. This paper aims to highlight why they are generally an unsatisfactory tool for the measurement and classification of animal colours and why colour codes based on HTML (really RGB) standards, as advocated in a recent paper, are particularly inappropriate. There are many theoretical arguments against the use of colour charts, not least that human colour vision differs markedly from that of most other animals. However, the focus of this paper is the concern that, even when applied to humans, there is no simple 1:1 mapping from an RGB colour space to the perceived colours in a chart (the results are both printer- and illumination-dependent). We support our criticisms with data from colour matching experiments with humans, involving self-made, printed colour charts. Colour matching experiments with printed charts involving 11 subjects showed that the choices made by individuals were significantly different between charts that had exactly the same RGB values, but were produced from different printers. Furthermore, individual matches tended to vary under different lighting conditions. Spectrophotometry of the colour charts showed that the reflectance spectra of the charts varied greatly between printers and that equal steps in RGB space were often far from equal in terms of reflectance on the printed charts. In addition to outlining theoretical criticisms of the use of colour charts, our empirical results show that: individuals vary in their perception of colours, that different printers produce strikingly different results when reproducing what should be the same chart, and that the characteristics of the light irradiating the surface do affect colour perception. Therefore, we urge great caution in the use of colour charts to study animal colour signals. They should be used only as a last resort and in full knowledge of their limitations, with

  19. Impact of portal hemodynamics on Doppler ultrasonography for predicting decompensation and long-term outcomes in patients with cirrhosis.

    PubMed

    Kondo, Takayuki; Maruyama, Hitoshi; Sekimoto, Tadashi; Shimada, Taro; Takahashi, Masanori; Okugawa, Hidehiro; Yokosuka, Osamu

    2016-01-01

    Significance of portal hemodynamics for non-invasive marker of cirrhosis remains unclear. The aim was to determine the value of portal hemodynamics on Doppler ultrasound for predicting decompensation and prognosis in cirrhosis. This retrospective study comprised 236 cirrhotic patients (132 males, 104 females; age 63.7 ± 11.3 years; 110 compensated, 126 decompensated). Clinical data, including Doppler findings, were analyzed with respect to decompensation and prognosis. The median follow-up period was 33.2 months (0.1-95.4). Fifty-three patients developed clinical decompensation, 13 patients received liver transplantation, and 71 died. Higher model for end-stage liver disease score (p < 0.001) at baseline was the significant factor for the presence of decompensation. Higher alanine transaminase (p = 0.020), lower albumin (p = 0.002) and lower mean velocity in the portal trunk (p = 0.038) were significant factors for developing decompensation (best cut-off value: Alanine transaminase > 31 IU/L, albumin < 3.6 g/dL, and portal trunk < 12.8 cm/s). The cumulative incidence of decompensation was higher in patients with portal trunk < 12.8 cm/s (22.5% at 1 year, 71.2% at 5 years) than those without (6.9% at 1 year, 35.4% at 5 years; p < 0.001). The significant prognostic factors were hepatocellular carcinoma (p = 0.036) and lower albumin (p = 0.008) for compensated patients, and reversed portal flow (p = 0.028), overt ascites (p < 0.001), and higher bilirubin (p < 0.001) for decompensated patients. Portal hemodynamics offer a non-invasive marker for decompensation and prognosis of cirrhosis, suggesting a future direction for practical management.

  20. Comparison of transrectal photoacoustic, Doppler, and magnetic resonance imaging for prostate cancer detection

    NASA Astrophysics Data System (ADS)

    Ishihara, Miya; Horiguchi, Akio; Shinmoto, Hiroshi; Tsuda, Hitoshi; Irisawa, Kaku; Wada, Takatsugu; Asano, Tomohiko

    2016-03-01

    Transrectal ultrasonography (TRUS) is the most popular imaging modality for diagnosing and treating prostate cancer. TRUS-guided prostate biopsy is mandatory for the histological diagnosis of patients with elevated serum prostatespecific antigen (PSA), but its diagnostic accuracy is not satisfactory due to TRUS's low resolution. As a result, a considerable number of patients are required to undergo an unnecessary repeated biopsy. Photoacoustic imaging (PAI) can be used to provide microvascular network imaging using hemoglobin as an intrinsic, optical absorption molecule. We developed an original TRUS-type PAI probe consisting of a micro-convex array transducer with an optical illumination system to provide superimposed PAI and ultrasound images. TRUS-type PAI has the advantage of having much higher resolution and greater contrast than does Doppler TRUS. The purpose of this study was to demonstrate the clinical feasibility of the transrectal PAI system. We performed a clinical trial to compare the image of the cancerous area obtained by transrectal PAI with that obtained by TRUS Doppler during prostate biopsy. The obtained prostate biopsy cores were stained with anti-CD34 antibodies to provide a microvascular distribution map. We also confirmed its consistency with PAI and pre-biopsy MRI findings. Our study demonstrated that transrectal identification of tumor angiogenesis under superimposed photoacoustic and ultrasound images was easier than that under TRUS alone. We recognized a consistent relationship between PAI and MRI findings in most cases. However, there were no correspondences in some cases.

  1. Learning curve of office-based ultrasonography for rotator cuff tendons tears.

    PubMed

    Ok, Ji-Hoon; Kim, Yang-Soo; Kim, Jung-Man; Yoo, Tae-Wook

    2013-07-01

    To compare the accuracy of ultrasonography and MR arthrography (MRA) imaging in detecting of rotator cuff tears with arthroscopic finding used as the reference standard. The ultrasonography and MRA findings of 51 shoulders that underwent the arthroscopic surgery were prospectively analysed. Two orthopaedic doctors independently performed ultrasonography and interpreted the findings at the office. The tear size measured at ultrasonography and MRA was compared with the size measured at surgery using Pearson correlation coefficients (r). The sensitivity, specificity, accuracy, positive predictive value, negative predictive value and false-positive rate were calculated for a diagnosis of partial-and full-thickness rotator cuff tears. The kappa coefficient was calculated to verify the inter-observer agreement. The sensitivity of ultrasonography and MRA for detecting partial-thickness tears was 45.5 and 72.7 %, and that for full-thickness tears was 80.0 and 100 %, respectively. The accuracy of ultrasonograpy and MRA for detecting partial-thickness tears was 45.1 and 88.2 %, and that for full-thickness tears was 82.4 and 98 %, respectively. Tear size measured based on ultrasonography examination showed a poor correlation with the size measured at arthroscopic surgery (r = 0.21; p < 0.05). However, tear size estimated by MRA showed a strong correlation (r = 0.75; p < 0.05). The kappa coefficient was 0.47 between the two independent examiners. The accuracy of office-based ultrasonography for beginner orthopaedic surgeons to detect full-thickness rotator cuff tears was comparable to that of MRA but was less accurate for detecting partial-thickness tears and torn size measurement. Inter-observer agreement on the interpretation was fair. These results highlight the importance of the correct technique and experience in operation of ultrasonography in shoulder joint. Diagnostic study, Level II.

  2. Diagnostic accuracy of transabdominal ultrasonography for gallbladder polyps: systematic review.

    PubMed

    Martin, Erin; Gill, Richdeep; Debru, Estifanos

    2018-06-01

    Previous research has shown variable but generally poor accuracy of transabdominal ultrasonography in the diagnosis of gallbladder polyps. We performed a systematic review of the literature with the aim of helping surgeons interpret and apply these findings in the preoperative assessment and counselling of their patients. We searched PubMed, MEDLINE and the Cochrane database using the keywords "gallbladder," "polyp," "ultrasound," "pathology" and "diagnosis" for English-language articles published after 1990 with the full-text article available through our institutional subscriptions. Polyps were defined as immobile features that on transabdominal ultrasonography appear to arise from the mucosa and that lack an acoustic shadow, and pseudopolyps were defined as features such as inflammation, hyperplasia, cholesterolosis and adenomyomatosis that convey no risk of malignant transformation. The search returned 1816 articles, which were narrowed down to 14 primary sources involving 15 497 (range 23-13 703) patients who had preoperative transabdominal ultrasonography, underwent cholecystectomy and had postoperative pathology results available. Among the 1259 patients in whom a gallbladder polyp was diagnosed on ultrasonography, 188 polyps were confirmed as true polyps on pathologic examination, and 81 of these were found to be malignant. Of the 14 238 patients for whom a polyp was not seen on ultrasonography, 38 had a true polyp on pathologic examination, none of which were malignant. For true gallbladder polyps, transabdominal ultrasonography had a sensitivity of 83.1%, specificity of 96.3%, positive predictive value of 14.9% (7.0% for malignant polyps) and negative predictive value of 99.7%. Transabdominal ultrasonography has a high false-positive rate (85.1%) for the diagnosis of gallbladder polyps. Further study of alternative imaging modalities and reevaluation of existing management guidelines are warranted.

  3. Evaluation of meteorological airborne Doppler radar

    NASA Technical Reports Server (NTRS)

    Hildebrand, P. H.; Mueller, C. K.

    1984-01-01

    This paper will discuss the capabilities of airborne Doppler radar for atmospheric sciences research. The evaluation is based on airborne and ground based Doppler radar observations of convective storms. The capability of airborne Doppler radar to measure horizontal and vertical air motions is evaluated. Airborne Doppler radar is shown to be a viable tool for atmospheric sciences research.

  4. Colour dependence of zodiacal light models

    NASA Technical Reports Server (NTRS)

    Giese, R. H.; Hanner, M. S.; Leinert, C.

    1973-01-01

    Colour models of the zodiacal light in the ecliptic have been calculated for both dielectric and metallic particles in the sub-micron and micron size range. Two colour ratios were computed, a blue ratio and a red ratio. The models with a size distribution proportional to s to the -2.5 power ds (where s is the particle radius) generally show a colour close to the solar colour and almost independent of elongation. Especially in the blue colour ratio there is generally no significant dependence on the lower cutoff size (0.1-1 micron). The main feature of absorbing particles is a reddening at small elongations. The models for size distributions proportional to s to the -4 power ds show larger departures from solar colour and more variation with model parameters. Colour measurements, including red and near infra-red, therefore are useful to distinguish between flat and steep size spectra and to verify the presence of slightly absorbing particles.

  5. Evolution of colour vision in mammals.

    PubMed

    Jacobs, Gerald H

    2009-10-12

    Colour vision allows animals to reliably distinguish differences in the distributions of spectral energies reaching the eye. Although not universal, a capacity for colour vision is sufficiently widespread across the animal kingdom to provide prima facie evidence of its importance as a tool for analysing and interpreting the visual environment. The basic biological mechanisms on which vertebrate colour vision ultimately rests, the cone opsin genes and the photopigments they specify, are highly conserved. Within that constraint, however, the utilization of these basic elements varies in striking ways in that they appear, disappear and emerge in altered form during the course of evolution. These changes, along with other alterations in the visual system, have led to profound variations in the nature and salience of colour vision among the vertebrates. This article concerns the evolution of colour vision among the mammals, viewing that process in the context of relevant biological mechanisms, of variations in mammalian colour vision, and of the utility of colour vision.

  6. Evolution of colour vision in mammals

    PubMed Central

    Jacobs, Gerald H.

    2009-01-01

    Colour vision allows animals to reliably distinguish differences in the distributions of spectral energies reaching the eye. Although not universal, a capacity for colour vision is sufficiently widespread across the animal kingdom to provide prima facie evidence of its importance as a tool for analysing and interpreting the visual environment. The basic biological mechanisms on which vertebrate colour vision ultimately rests, the cone opsin genes and the photopigments they specify, are highly conserved. Within that constraint, however, the utilization of these basic elements varies in striking ways in that they appear, disappear and emerge in altered form during the course of evolution. These changes, along with other alterations in the visual system, have led to profound variations in the nature and salience of colour vision among the vertebrates. This article concerns the evolution of colour vision among the mammals, viewing that process in the context of relevant biological mechanisms, of variations in mammalian colour vision, and of the utility of colour vision. PMID:19720656

  7. Finnish Meteorological Institute Doppler Lidar

    DOE Data Explorer

    Ewan OConnor

    2015-03-27

    This doppler lidar system provides co-polar and cross polar attenuated backscatter coefficients,signal strength, and doppler velocities in the cloud and in the boundary level, including uncertainties for all parameters. Using the doppler beam swinging DBS technique, and Vertical Azimuthal Display (VAD) this system also provides vertical profiles of horizontal winds.

  8. Synaesthetic colour in the brain: beyond colour areas. A functional magnetic resonance imaging study of synaesthetes and matched controls.

    PubMed

    van Leeuwen, Tessa M; Petersson, Karl Magnus; Hagoort, Peter

    2010-08-10

    In synaesthesia, sensations in a particular modality cause additional experiences in a second, unstimulated modality (e.g., letters elicit colour). Understanding how synaesthesia is mediated in the brain can help to understand normal processes of perceptual awareness and multisensory integration. In several neuroimaging studies, enhanced brain activity for grapheme-colour synaesthesia has been found in ventral-occipital areas that are also involved in real colour processing. Our question was whether the neural correlates of synaesthetically induced colour and real colour experience are truly shared. First, in a free viewing functional magnetic resonance imaging (fMRI) experiment, we located main effects of synaesthesia in left superior parietal lobule and in colour related areas. In the left superior parietal lobe, individual differences between synaesthetes (projector-associator distinction) also influenced brain activity, confirming the importance of the left superior parietal lobe for synaesthesia. Next, we applied a repetition suppression paradigm in fMRI, in which a decrease in the BOLD (blood-oxygenated-level-dependent) response is generally observed for repeated stimuli. We hypothesized that synaesthetically induced colours would lead to a reduction in BOLD response for subsequently presented real colours, if the neural correlates were overlapping. We did find BOLD suppression effects induced by synaesthesia, but not within the colour areas. Because synaesthetically induced colours were not able to suppress BOLD effects for real colour, we conclude that the neural correlates of synaesthetic colour experience and real colour experience are not fully shared. We propose that synaesthetic colour experiences are mediated by higher-order visual pathways that lie beyond the scope of classical, ventral-occipital visual areas. Feedback from these areas, in which the left parietal cortex is likely to play an important role, may induce V4 activation and the percept of

  9. Colour preferences in nest-building zebra finches.

    PubMed

    Muth, Felicity; Steele, Matthew; Healy, Susan D

    2013-10-01

    Some bird species are selective in the materials they choose for nest building, preferring, for example, materials of one colour to others. However, in many cases the cause of these preferences is not clear. One of those species is the zebra finch, which exhibits strong preferences for particular colours of nest material. In an attempt to determine why these birds strongly prefer one colour of material over another, we compared the preferences of paired male zebra finches for nest material colour with their preferences for food of the same colours. We found that birds did indeed prefer particular colours of nest material (in most cases blue) but that they did not generally prefer food of one colour over the other colours. It appears, then, that a preference for one colour or another of nest material is specific to the nest-building context. This article is part of a Special Issue entitled: insert SI title. Copyright © 2013 Elsevier B.V. All rights reserved.

  10. Doppler radar flowmeter

    DOEpatents

    Petlevich, Walter J.; Sverdrup, Edward F.

    1978-01-01

    A Doppler radar flowmeter comprises a transceiver which produces an audio frequency output related to the Doppler shift in frequency between radio waves backscattered from particulate matter carried in a fluid and the radiated radio waves. A variable gain amplifier and low pass filter are provided for amplifying and filtering the transceiver output. A frequency counter having a variable triggering level is also provided to determine the magnitude of the Doppler shift. A calibration method is disclosed wherein the amplifier gain and frequency counter trigger level are adjusted to achieve plateaus in the output of the frequency counter and thereby allow calibration without the necessity of being able to visually observe the flow.

  11. Xeroradiography and ultrasonography in the evaluation of a penile injury.

    PubMed

    Oesterling, J E; Bromberg, W D; Albertsen, P C

    1986-04-01

    A 34-year-old white man presented with severe penile cellulitis following injection of epoxy glue into the shaft of the penis. Preoperative xeroradiography and ultrasonography localized the hardened masses of glue to the left corpus cavernosum and subcutaneous tissues. Under the guidance of intraoperative ultrasonography this foreign material was removed surgically. Postoperatively, the cellulitis resolved promptly and xeroradiography demonstrated no residual fragments. Although various modalities, including computerized tomography and roentgenography, are available to detect foreign bodies in soft tissues, xeroradiography and ultrasonography are ideally suited for use in the male external genitalia.

  12. Optimisation of colour schemes to accurately display mass spectrometry imaging data based on human colour perception.

    PubMed

    Race, Alan M; Bunch, Josephine

    2015-03-01

    The choice of colour scheme used to present data can have a dramatic effect on the perceived structure present within the data. This is of particular significance in mass spectrometry imaging (MSI), where ion images that provide 2D distributions of a wide range of analytes are used to draw conclusions about the observed system. Commonly employed colour schemes are generally suboptimal for providing an accurate representation of the maximum amount of data. Rainbow-based colour schemes are extremely popular within the community, but they introduce well-documented artefacts which can be actively misleading in the interpretation of the data. In this article, we consider the suitability of colour schemes and composite image formation found in MSI literature in the context of human colour perception. We also discuss recommendations of rules for colour scheme selection for ion composites and multivariate analysis techniques such as principal component analysis (PCA).

  13. Attentional capture by masked colour singletons.

    PubMed

    Ansorge, Ulrich; Horstmann, Gernot; Worschech, Franziska

    2010-09-15

    We tested under which conditions a colour singleton of which an observer is unaware captures attention. To prevent visual awareness of the colour singleton, we used backward masking. We find that a masked colour singleton cue captures attention if it matches the observer's goal to search for target colours but not if it is task-irrelevant. This is also reflected in event-related potentials to the visible target: the masked goal-matching cue elicits an attentional potential (N2pc) in a target search task. By contrast, a non-matching but equally strong masked colour singleton cue failed to elicit a capture effect and an N2pc. Results are discussed with regard to currently pertaining conceptions of attentional capture by colour singletons. Copyright 2010 Elsevier Ltd. All rights reserved.

  14. Doppler-corrected differential detection system

    NASA Technical Reports Server (NTRS)

    Simon, Marvin K. (Inventor); Divsalar, Dariush (Inventor)

    1991-01-01

    Doppler in a communication system operating with a multiple differential phase-shift-keyed format (MDPSK) creates an adverse phase shift in an incoming signal. An open loop frequency estimation is derived from a Doppler-contaminated incoming signal. Based upon the recognition that, whereas the change in phase of the received signal over a full symbol contains both the differentially encoded data and the Doppler induced phase shift, the same change in phase over half a symbol (within a given symbol interval) contains only the Doppler induced phase shift, and the Doppler effect can be estimated and removed from the incoming signal. Doppler correction occurs prior to the receiver's final output of decoded data. A multiphase system can operate with two samplings per symbol interval at no penalty in signal-to-noise ratio provided that an ideal low pass pre-detection filter is employed, and two samples, at 1/4 and 3/4 of the symbol interval T sub s, are taken and summed together prior to incoming signal data detection.

  15. Clinical colour vision tests.

    PubMed

    Dain, Stephen J

    2004-07-01

    The structure and function of the available and significant clinical colour vision tests are reviewed in the light of the needs in the clinical examination of congenital and acquired colour vision deficiencies. The tests are grouped and described as pseudo-isochromatic plates, arrangement tests, matching tests and vocational tests. The colorimetric constructions of the test types are described and the efficiency of their performance and usefulness discussed. Recommendations are made for basic and extended test batteries, when examining of congenital and acquired colour vision deficiencies in the consulting room.

  16. Determinants of Colour Constancy and the Blue Bias

    PubMed Central

    Gegenfurtner, Karl

    2017-01-01

    We investigated several sensory and cognitive determinants of colour constancy across 40 illumination hues. In the first experiment, we measured colour naming for the illumination and for the colour induced by the illumination on the colorimetric grey. Results confirmed that the induced colours are approximately complementary to the colour of the illumination. In the second experiment, we measured colour constancy using achromatic adjustments. Average colour constancy was perfect under the blue daylight illumination and decreased in colour directions away from the blue daylight illumination due to undershooting and a strong blue bias. Apart from this blue bias, colour constancy was not related to illumination discrimination and to chromatic detection measured previously with the same setup and stimuli. We also observed a strong negative relationship between the degree of colour constancy and the consensus of naming the illumination colour. Constancy coincided with a low naming consensus, in particular because bluish illumination colours were sometimes seen as achromatic. Blue bias and category consensus alone explained >68%, and all determinants together explained >94% of the variance of achromatic adjustments. These findings suggest that colour constancy is optimised for blue daylight. PMID:29348910

  17. Colour change in cyanosis and the confusions of congenital colour vision deficient observers.

    PubMed

    McNamara, Renae; Taylor, Clair M; McKenzie, David K; Coroneo, Minas T; Dain, Stephen J

    2010-09-01

    Visual recognition of cyanosis is an important clinical activity. While pulse oximetry is almost universal in the hospital environment, there are circumstances where it is not available or may be unreliable. Cyanosis recognition is affected by lighting colour. In addition, there is, mainly anecdotal, evidence that people with greater colour vision deficiencies (CVDs) have particular difficulty and there is no effective lighting strategy to assist in the observation. The change of blood colour with oxygenation has been shown to lie close to the direction of colour confusions made by congenital red-green dichromats. The important sites of observation are lips, nail beds and palm creases. 10 subjects who were known to be chronically hypoxaemic were recruited from the chronic respiratory program. Their blood oxygen saturation (SpO(2)) varied from 84% to 96% pre-exercise, and 61-84% post-exercise. Ten normal subjects were recruited whose SpO(2) was 99% or 100%. The spectral radiances of lips, nail beds and palm creases were measured using a telespectroradiometer and compared with the spectral radiances of a white tile of known spectral reflectances measured in the same location. This is a non-contact method of measurement, avoiding the blanching caused by pressure of contact methods. The spectral reflectances were calculated, and the chromaticities calculated for a Planckian radiator T = 4000K. Measurements on lips yielded the most consistent results. The colour changes pre- and post-exercise and compared with normal colour lie generally along a deutan confusion line. These results show the direction of the colour change and confirm the, previously anecdotal, difficulties in detecting cyanosis by observers with CVDs. © 2010 The Authors, Ophthalmic and Physiological Optics © 2010 The College of Optometrists.

  18. Interactions between colour-producing mechanisms and their effects on the integumentary colour palette.

    PubMed

    Shawkey, Matthew D; D'Alba, Liliana

    2017-07-05

    Animal integumentary coloration plays a crucial role in visual communication and camouflage, and varies extensively among and within species and populations. To understand the pressures underlying such diversity, it is essential to elucidate the mechanisms by which animals have created novel integumentary coloration. Colours can be produced by selective absorption of light by skin pigments, through light scattering by structured or unstructured tissues, or by a combination of pigments and nanostructures. In this review, we highlight our current understanding of the interactions between pigments and structural integumentary tissues and molecules. We analyse the available evidence suggesting that these combined mechanisms are capable of creating colours and optical properties unachievable by either mechanism alone, thereby effectively expanding the animal colour palette. Moreover, structural and pigmentary colour mechanisms frequently interact in unexpected and overlooked ways, suggesting that classification of colours as being of any particular type may be difficult. Finally, we discuss how these mixtures are useful for investigating the largely unknown genetic, developmental and physical processes generating phenotypic diversity.This article is part of the themed issue 'Animal coloration: production, perception, function and application'. © 2017 The Author(s).

  19. Point-of-care ultrasonography by pediatric emergency physicians. Policy statement.

    PubMed

    Marin, Jennifer R; Lewiss, Resa E

    2015-04-01

    Point-of-care ultrasonography is increasingly being used to facilitate accurate and timely diagnoses and to guide procedures. It is important for pediatric emergency physicians caring for patients in the emergency department to receive adequate and continued point-of-care ultrasonography training for those indications used in their practice setting. Emergency departments should have credentialing and quality assurance programs. Pediatric emergency medicine fellowships should provide appropriate training to physician trainees. Hospitals should provide privileges to physicians who demonstrate competency in point-of-care ultrasonography. Ongoing research will provide the necessary measures to define the optimal training and competency assessment standards. Requirements for credentialing and hospital privileges will vary and will be specific to individual departments and hospitals. As more physicians are trained and more research is completed, there should be one national standard for credentialing and privileging in point-of-care ultrasonography for pediatric emergency physicians.

  20. Conspicuous plumage colours are highly variable

    PubMed Central

    Szecsenyi, Beatrice; Nakagawa, Shinichi; Peters, Anne

    2017-01-01

    Elaborate ornamental traits are often under directional selection for greater elaboration, which in theory should deplete underlying genetic variation. Despite this, many ornamental traits appear to remain highly variable and how this essential variation is maintained is a key question in evolutionary biology. One way to address this question is to compare differences in intraspecific variability across different types of traits to determine whether high levels of variation are associated with specific trait characteristics. Here we assess intraspecific variation in more than 100 plumage colours across 55 bird species to test whether colour variability is linked to their level of elaboration (indicated by degree of sexual dichromatism and conspicuousness) or their condition dependence (indicated by mechanism of colour production). Conspicuous colours had the highest levels of variation and conspicuousness was the strongest predictor of variability, with high explanatory power. After accounting for this, there were no significant effects of sexual dichromatism or mechanisms of colour production. Conspicuous colours may entail higher production costs or may be more sensitive to disruptions during production. Alternatively, high variability could also be related to increased perceptual difficulties inherent to discriminating highly elaborate colours. Such psychophysical effects may constrain the exaggeration of animal colours. PMID:28100823

  1. Conspicuous plumage colours are highly variable.

    PubMed

    Delhey, Kaspar; Szecsenyi, Beatrice; Nakagawa, Shinichi; Peters, Anne

    2017-01-25

    Elaborate ornamental traits are often under directional selection for greater elaboration, which in theory should deplete underlying genetic variation. Despite this, many ornamental traits appear to remain highly variable and how this essential variation is maintained is a key question in evolutionary biology. One way to address this question is to compare differences in intraspecific variability across different types of traits to determine whether high levels of variation are associated with specific trait characteristics. Here we assess intraspecific variation in more than 100 plumage colours across 55 bird species to test whether colour variability is linked to their level of elaboration (indicated by degree of sexual dichromatism and conspicuousness) or their condition dependence (indicated by mechanism of colour production). Conspicuous colours had the highest levels of variation and conspicuousness was the strongest predictor of variability, with high explanatory power. After accounting for this, there were no significant effects of sexual dichromatism or mechanisms of colour production. Conspicuous colours may entail higher production costs or may be more sensitive to disruptions during production. Alternatively, high variability could also be related to increased perceptual difficulties inherent to discriminating highly elaborate colours. Such psychophysical effects may constrain the exaggeration of animal colours. © 2017 The Author(s).

  2. Ultrasound assessed thickness of burn scars in association with laser Doppler imaging determined depth of burns in paediatric patients.

    PubMed

    Wang, Xue-Qing; Mill, Julie; Kravchuk, Olena; Kimble, Roy M

    2010-12-01

    This study describes the ultrasound assessment of burn scars in paediatric patients and the association of these scar thickness with laser Doppler imaging (LDI) determined burn depth. A total of 60 ultrasound scar assessments were conducted on 33 scars from 21 paediatric burn patients at 3, 6 and 9 months after-burn. The mean of peak scar thickness was 0.39±0.032 cm, with the thickest at 6 months (0.40±0.036 cm). There were 17 scald burn scars (0.34±0.045 cm), 4 contact burn scars (0.61±0.092 cm), and 10 flame burn scars (0.42±0.058 cm). Each group of scars followed normal distributions. Twenty-three scars had original burns successfully scanned by LDI and various depths of burns were presented by different colours according to blood perfusion units (PU), with dark blue <125, light blue 125-250, and green 250-440 PU. The thickness of these scars was significantly different between the predominant colours of burns, with the thinnest scars for green coloured burns and the thickest for dark blue coloured burns. Within light blue burns, grafted burns healed with significantly thinner scars than non-grafted burns. This study indicates that LDI can be used for predicting the risk of hypertrophic scarring and for guiding burn care. To our knowledge, this is the first study to correlate the thickness of burns scars by ultrasound scan with burn depth determined by LDI. Copyright © 2010 Elsevier Ltd and ISBI. All rights reserved.

  3. Artificial selection for food colour preferences

    PubMed Central

    Cole, Gemma L.; Endler, John A.

    2015-01-01

    Colour is an important factor in food detection and acquisition by animals using visually based foraging. Colour can be used to identify the suitability of a food source or improve the efficiency of food detection, and can even be linked to mate choice. Food colour preferences are known to exist, but whether these preferences are heritable and how these preferences evolve is unknown. Using the freshwater fish Poecilia reticulata, we artificially selected for chase behaviour towards two different-coloured moving stimuli: red and blue spots. A response to selection was only seen for chase behaviours towards the red, with realized heritabilities ranging from 0.25 to 0.30. Despite intense selection, no significant chase response was recorded for the blue-selected lines. This lack of response may be due to the motion-detection mechanism in the guppy visual system and may have novel implications for the evolvability of responses to colour-related signals. The behavioural response to several colours after five generations of selection suggests that the colour opponency system of the fish may regulate the response to selection. PMID:25740894

  4. Laser Doppler Velocimetry Workshop

    NASA Technical Reports Server (NTRS)

    Owen, R. B.

    1979-01-01

    The potential of laser Doppler velocimetry as a technique for use in mapping flows in the several fluid systems under development for doing research on low-gravity processes, is investigated. Laser Doppler velocimetry techniques, equipment, and applications are summarized.

  5. The unsuitability of html-based colour charts for estimating animal colours – a comment on Berggren and Merilä (2004)

    PubMed Central

    Stevens, Martin; Cuthill, Innes C

    2005-01-01

    Background A variety of techniques are used to study the colours of animal signals, including the use of visual matching to colour charts. This paper aims to highlight why they are generally an unsatisfactory tool for the measurement and classification of animal colours and why colour codes based on HTML (really RGB) standards, as advocated in a recent paper, are particularly inappropriate. There are many theoretical arguments against the use of colour charts, not least that human colour vision differs markedly from that of most other animals. However, the focus of this paper is the concern that, even when applied to humans, there is no simple 1:1 mapping from an RGB colour space to the perceived colours in a chart (the results are both printer- and illumination-dependent). We support our criticisms with data from colour matching experiments with humans, involving self-made, printed colour charts. Results Colour matching experiments with printed charts involving 11 subjects showed that the choices made by individuals were significantly different between charts that had exactly the same RGB values, but were produced from different printers. Furthermore, individual matches tended to vary under different lighting conditions. Spectrophotometry of the colour charts showed that the reflectance spectra of the charts varied greatly between printers and that equal steps in RGB space were often far from equal in terms of reflectance on the printed charts. Conclusion In addition to outlining theoretical criticisms of the use of colour charts, our empirical results show that: individuals vary in their perception of colours, that different printers produce strikingly different results when reproducing what should be the same chart, and that the characteristics of the light irradiating the surface do affect colour perception. Therefore, we urge great caution in the use of colour charts to study animal colour signals. They should be used only as a last resort and in full

  6. IRIS COLOUR CLASSIFICATION SCALES--THEN AND NOW.

    PubMed

    Grigore, Mariana; Avram, Alina

    2015-01-01

    Eye colour is one of the most obvious phenotypic traits of an individual. Since the first documented classification scale developed in 1843, there have been numerous attempts to classify the iris colour. In the past centuries, iris colour classification scales has had various colour categories and mostly relied on comparison of an individual's eye with painted glass eyes. Once photography techniques were refined, standard iris photographs replaced painted eyes, but this did not solve the problem of painted/ printed colour variability in time. Early clinical scales were easy to use, but lacked objectivity and were not standardised or statistically tested for reproducibility. The era of automated iris colour classification systems came with the technological development. Spectrophotometry, digital analysis of high-resolution iris images, hyper spectral analysis of the human real iris and the dedicated iris colour analysis software, all accomplished an objective, accurate iris colour classification, but are quite expensive and limited in use to research environment. Iris colour classification systems evolved continuously due to their use in a wide range of studies, especially in the fields of anthropology, epidemiology and genetics. Despite the wide range of the existing scales, up until present there has been no generally accepted iris colour classification scale.

  7. Independent effects of colour on object identification and memory.

    PubMed

    Lloyd-Jones, Toby J; Nakabayashi, Kazuyo

    2009-02-01

    We examined the effects of colour on object identification and memory using a study-test priming procedure with a coloured-object decision task at test (i.e., deciding whether an object is correctly coloured). Objects were selected to have a single associated colour and were either correctly or incorrectly coloured. In addition, object shape and colour were either spatially integrated (i.e., colour fell on the object surface) or spatially separated (i.e., colour formed the background to the object). Transforming the colour of an object from study to test (e.g., from a yellow banana to a purple banana) reduced priming of response times, as compared to when the object was untransformed. This utilization of colour information in object memory was not contingent upon colour falling on the object surface or whether the resulting configuration was of a correctly or incorrectly coloured object. In addition, we observed independent effects of colour on response times, whereby coloured-object decisions were more efficient for correctly than for incorrectly coloured objects but only when colour fell on the object surface. These findings provide evidence for two distinct mechanisms of shape-colour binding in object processing.

  8. Scalable, full-colour and controllable chromotropic plasmonic printing.

    PubMed

    Xue, Jiancai; Zhou, Zhang-Kai; Wei, Zhiqiang; Su, Rongbin; Lai, Juan; Li, Juntao; Li, Chao; Zhang, Tengwei; Wang, Xue-Hua

    2015-11-16

    Plasmonic colour printing has drawn wide attention as a promising candidate for the next-generation colour-printing technology. However, an efficient approach to realize full colour and scalable fabrication is still lacking, which prevents plasmonic colour printing from practical applications. Here we present a scalable and full-colour plasmonic printing approach by combining conjugate twin-phase modulation with a plasmonic broadband absorber. More importantly, our approach also demonstrates controllable chromotropic capability, that is, the ability of reversible colour transformations. This chromotropic capability affords enormous potentials in building functionalized prints for anticounterfeiting, special label, and high-density data encryption storage. With such excellent performances in functional colour applications, this colour-printing approach could pave the way for plasmonic colour printing in real-world commercial utilization.

  9. Scalable, full-colour and controllable chromotropic plasmonic printing

    PubMed Central

    Xue, Jiancai; Zhou, Zhang-Kai; Wei, Zhiqiang; Su, Rongbin; Lai, Juan; Li, Juntao; Li, Chao; Zhang, Tengwei; Wang, Xue-Hua

    2015-01-01

    Plasmonic colour printing has drawn wide attention as a promising candidate for the next-generation colour-printing technology. However, an efficient approach to realize full colour and scalable fabrication is still lacking, which prevents plasmonic colour printing from practical applications. Here we present a scalable and full-colour plasmonic printing approach by combining conjugate twin-phase modulation with a plasmonic broadband absorber. More importantly, our approach also demonstrates controllable chromotropic capability, that is, the ability of reversible colour transformations. This chromotropic capability affords enormous potentials in building functionalized prints for anticounterfeiting, special label, and high-density data encryption storage. With such excellent performances in functional colour applications, this colour-printing approach could pave the way for plasmonic colour printing in real-world commercial utilization. PMID:26567803

  10. Grapheme-colour synaesthesia improves detection of embedded shapes, but without pre-attentive 'pop-out' of synaesthetic colour.

    PubMed

    Ward, Jamie; Jonas, Clare; Dienes, Zoltan; Seth, Anil

    2010-04-07

    For people with synaesthesia letters and numbers may evoke experiences of colour. It has been previously demonstrated that these synaesthetes may be better at detecting a triangle made of 2s among a background of 5s if they perceive 5 and 2 as having different synaesthetic colours. However, other studies using this task (or tasks based on the same principle) have failed to replicate the effect or have suggested alternative explanations of the effect. In this study, we repeat the original study on a larger group of synaesthetes (n = 36) and include, for the first time, an assessment of their self-reported colour experiences. We show that synaesthetes do have a general advantage over controls on this task. However, many synaesthetes report no colour experiences at all during the task. Synaesthetes who do report colour typically experience around one third of the graphemes in the display as coloured. This is more consistent with theories of synaesthesia in which spatial attention needs to be deployed to graphemes for conscious colour experiences to emerge than the interpretation based on 'pop-out'.

  11. Doppler color imaging. Principles and instrumentation.

    PubMed

    Kremkau, F W

    1992-01-01

    DCI acquires Doppler-shifted echoes from a cross-section of tissue scanned by an ultrasound beam. These echoes are then presented in color and superimposed on the gray-scale anatomic image of non-Doppler-shifted echoes received during the scan. The flow echoes are assigned colors according to the color map chosen. Usually red, yellow, or white indicates positive Doppler shifts (approaching flow) and blue, cyan, or white indicates negative shifts (receding flow). Green is added to indicate variance (disturbed or turbulent flow). Several pulses (the number is called the ensemble length) are needed to generate a color scan line. Linear, convex, phased, and annular arrays are used to acquire the gray-scale and color-flow information. Doppler color-flow instruments are pulsed-Doppler instruments and are subject to the same limitations, such as Doppler angle dependence and aliasing, as other Doppler instruments. Color controls include gain, TGC, map selection, variance on/off, persistence, ensemble length, color/gray priority. Nyquist limit (PRF), baseline shift, wall filter, and color window angle, location, and size. Doppler color-flow instruments generally have output intensities intermediate between those of gray-scale imaging and pulsed-Doppler duplex instruments. Although there is no known risk with the use of color-flow instruments, prudent practice dictates that they be used for medical indications and with the minimum exposure time and instrument output required to obtain the needed diagnostic information.

  12. A Bayesian Model of the Memory Colour Effect.

    PubMed

    Witzel, Christoph; Olkkonen, Maria; Gegenfurtner, Karl R

    2018-01-01

    According to the memory colour effect, the colour of a colour-diagnostic object is not perceived independently of the object itself. Instead, it has been shown through an achromatic adjustment method that colour-diagnostic objects still appear slightly in their typical colour, even when they are colourimetrically grey. Bayesian models provide a promising approach to capture the effect of prior knowledge on colour perception and to link these effects to more general effects of cue integration. Here, we model memory colour effects using prior knowledge about typical colours as priors for the grey adjustments in a Bayesian model. This simple model does not involve any fitting of free parameters. The Bayesian model roughly captured the magnitude of the measured memory colour effect for photographs of objects. To some extent, the model predicted observed differences in memory colour effects across objects. The model could not account for the differences in memory colour effects across different levels of realism in the object images. The Bayesian model provides a particularly simple account of memory colour effects, capturing some of the multiple sources of variation of these effects.

  13. A Bayesian Model of the Memory Colour Effect

    PubMed Central

    Olkkonen, Maria; Gegenfurtner, Karl R.

    2018-01-01

    According to the memory colour effect, the colour of a colour-diagnostic object is not perceived independently of the object itself. Instead, it has been shown through an achromatic adjustment method that colour-diagnostic objects still appear slightly in their typical colour, even when they are colourimetrically grey. Bayesian models provide a promising approach to capture the effect of prior knowledge on colour perception and to link these effects to more general effects of cue integration. Here, we model memory colour effects using prior knowledge about typical colours as priors for the grey adjustments in a Bayesian model. This simple model does not involve any fitting of free parameters. The Bayesian model roughly captured the magnitude of the measured memory colour effect for photographs of objects. To some extent, the model predicted observed differences in memory colour effects across objects. The model could not account for the differences in memory colour effects across different levels of realism in the object images. The Bayesian model provides a particularly simple account of memory colour effects, capturing some of the multiple sources of variation of these effects. PMID:29760874

  14. How temporal cues can aid colour constancy

    PubMed Central

    Foster, David H.; Amano, Kinjiro; Nascimento, Sérgio M. C.

    2007-01-01

    Colour constancy assessed by asymmetric simultaneous colour matching usually reveals limited levels of performance in the unadapted eye. Yet observers can readily discriminate illuminant changes on a scene from changes in the spectral reflectances of the surfaces making up the scene. This ability is probably based on judgements of relational colour constancy, in turn based on the physical stability of spatial ratios of cone excitations under illuminant changes. Evidence is presented suggesting that the ability to detect violations in relational colour constancy depends on temporal transient cues. Because colour constancy and relational colour constancy are closely connected, it should be possible to improve estimates of colour constancy by introducing similar transient cues into the matching task. To test this hypothesis, an experiment was performed in which observers made surface-colour matches between patterns presented in the same position in an alternating sequence with period 2 s or, as a control, presented simultaneously, side-by-side. The degree of constancy was significantly higher for sequential presentation, reaching 87% for matches averaged over 20 observers. Temporal cues may offer a useful source of information for making colour-constancy judgements. PMID:17515948

  15. Doppler ultrasound monitoring technology.

    PubMed

    Docker, M F

    1993-03-01

    Developments in the signal processing of Doppler ultrasound used for the detection of fetal heart rate (FHR) have improved the operation of cardiotocographs. These developments are reviewed and the advantages and disadvantages of the various Doppler and signal processing methods are compared.

  16. Colouring outside the lines

    NASA Astrophysics Data System (ADS)

    Commissariat, Tushna

    2017-10-01

    Walk into a bookshop today, or even a gift shop, and you will most likely come across an entire section of colouring books for adults. Visions of Numberland: a Colouring Journey Through the Mysteries of Maths by Alex Bellos and Edmund Harriss is one such book.

  17. The Categorisation of Non-Categorical Colours: A Novel Paradigm in Colour Perception

    PubMed Central

    Cropper, Simon J.; Kvansakul, Jessica G. S.; Little, Daniel R.

    2013-01-01

    In this paper, we investigate a new paradigm for studying the development of the colour ‘signal’ by having observers discriminate and categorize the same set of controlled and calibrated cardinal coloured stimuli. Notably, in both tasks, each observer was free to decide whether two pairs of colors were the same or belonged to the same category. The use of the same stimulus set for both tasks provides, we argue, an incremental behavioural measure of colour processing from detection through discrimination to categorisation. The measured data spaces are different for the two tasks, and furthermore the categorisation data is unique to each observer. In addition, we develop a model which assumes that the principal difference between the tasks is the degree of similarity between the stimuli which has different constraints for the categorisation task compared to the discrimination task. This approach not only makes sense of the current (and associated) data but links the processes of discrimination and categorisation in a novel way and, by implication, expands upon the previous research linking categorisation to other tasks not limited to colour perception. PMID:23536899

  18. The categorisation of non-categorical colours: a novel paradigm in colour perception.

    PubMed

    Cropper, Simon J; Kvansakul, Jessica G S; Little, Daniel R

    2013-01-01

    In this paper, we investigate a new paradigm for studying the development of the colour 'signal' by having observers discriminate and categorize the same set of controlled and calibrated cardinal coloured stimuli. Notably, in both tasks, each observer was free to decide whether two pairs of colors were the same or belonged to the same category. The use of the same stimulus set for both tasks provides, we argue, an incremental behavioural measure of colour processing from detection through discrimination to categorisation. The measured data spaces are different for the two tasks, and furthermore the categorisation data is unique to each observer. In addition, we develop a model which assumes that the principal difference between the tasks is the degree of similarity between the stimuli which has different constraints for the categorisation task compared to the discrimination task. This approach not only makes sense of the current (and associated) data but links the processes of discrimination and categorisation in a novel way and, by implication, expands upon the previous research linking categorisation to other tasks not limited to colour perception.

  19. Artificial selection for food colour preferences.

    PubMed

    Cole, Gemma L; Endler, John A

    2015-04-07

    Colour is an important factor in food detection and acquisition by animals using visually based foraging. Colour can be used to identify the suitability of a food source or improve the efficiency of food detection, and can even be linked to mate choice. Food colour preferences are known to exist, but whether these preferences are heritable and how these preferences evolve is unknown. Using the freshwater fish Poecilia reticulata, we artificially selected for chase behaviour towards two different-coloured moving stimuli: red and blue spots. A response to selection was only seen for chase behaviours towards the red, with realized heritabilities ranging from 0.25 to 0.30. Despite intense selection, no significant chase response was recorded for the blue-selected lines. This lack of response may be due to the motion-detection mechanism in the guppy visual system and may have novel implications for the evolvability of responses to colour-related signals. The behavioural response to several colours after five generations of selection suggests that the colour opponency system of the fish may regulate the response to selection. © 2015 The Author(s) Published by the Royal Society. All rights reserved.

  20. Red-green colour blindness in Singaporean children.

    PubMed

    Chia, Audrey; Gazzard, Gus; Tong, Louis; Zhang, Xiaoe; Sim, Ee-Ling; Fong, Allan; Mei Saw, Seang

    2008-07-01

    X-linked red-green colour blindness is the most common form of colour blindness. Various studies suggest that, worldwide, 2-8% of men are afflicted with this condition. The purpose of this study is to determine the prevalence of red-green colour blindness in Singaporean schoolchildren. A total of 1249 children aged 13-15 years were screened using the Ishihara 24-plate edition book during the School Cohort study of the Risk factors for Myopia visit. A total of 1210 children (96.8%) managed to correctly identify at least 13 of the initial 15 plates and were deemed to have normal colour vision.Thirty-three children (32 boys, one girl) were only able to identify nine or less plates and were considered to be colour blind. Overall, 5.4% (95% confidence interval 3%, 7%) of Chinese, 4.9% (1%, 9%) of Malay and 4.9% (2%, 11%) of Indian boys were colour blind (P = 0.97). Classification plates 16-17 were useful in determining deutran or protan tendencies in only 14 (43%) of the 33 children identified as being colour blind. 5.3% of boys and 0.2% of girls were found to be colour blind in this Singapore-based study. Although the Ishihara test proved useful in identifying colour-blind children, other tests are required to accurately classify the types of red-green colour blindness in these children.

  1. Exposure of Polish children to Southampton food colours.

    PubMed

    Gajda-Wyrębek, J; Kuźma, K; Świtka, A; Jarecka, J; Beresińska, M; Postupolski, J

    2017-01-01

    A study published in 2007 showed that the intake of six food colours (the so-called 'Southampton colours') may have an adverse effect on activity and attention in children. The present study set out to assess the exposure of Polish children (3 and 8-9 years old, n = 149) to six of the target colours. Two methods were used to evaluate colour consumption by children: scenario 1 using the maximum permitted levels (MPLs) and actual food consumption data; and scenario 2 using the actual levels in food and actual food consumption data. The data on the actual consumption of food containing the colours was collected using a 7-day questionnaire survey. The results of laboratory analysis of food consumed by children provided data on the actual levels of the colours in food. Consumption of the colours estimated by scenario 1 in any case did not exceed the acceptable daily intakes (ADIs) of the colours in both age groups of children. For more refined colour intake (scenario 2), isolated cases exceeding the ADI were recorded for four colours, but assuming that manufacturers comply with the current legislation on MPL of colours in food, the intake of the colours assessed in scenario 2 should not be a reason for exceeding of ADIs for the target food colours.

  2. Vascularity as assessed by Doppler intraoral ultrasound around the invasion front of tongue cancer is a predictor of pathological grade of malignancy and cervical lymph node metastasis.

    PubMed

    Yamamoto, Chika; Yuasa, Kenji; Okamura, Kazuhiko; Shiraishi, Tomoko; Miwa, Kunihiro

    2016-01-01

    To quantitatively evaluate the relationship of vascularity of tongue cancer as demonstrated on intraoral ultrasonography images and tumour thickness with pathological grade of malignancy and the presence of cervical lymph node metastases. 18 patients with tongue cancer were enrolled in this retrospective study. Using Doppler ultrasonography images of the invasion front of the cancers along the length of their tumour boundaries, three vascular indexes were analysed quantitatively, namely ratio of blood flow signal area within the cancer to whole tumour area (BAR), blood flow signal number ratio (BNR) and blood flow signal width ratio (BWR). The associations between these three indexes and occurrence of cervical lymph node metastasis and pathological grade of malignancy [Yamamoto-Kohama (YK) classification] were assessed. Furthermore, the relationship between tumour thickness and occurrence of cervical lymph node metastasis was evaluated on B-mode intraoral ultrasonography images. There was no significant association between BAR and tumour thickness or occurrence of cervical lymph node metastasis. The BNRs and BWRs of patients with cervical lymph node metastasis were significantly higher than those of patients without nodal involvement. The BWRs of patients with high-grade malignancy (YK-4C) were significantly higher than those of patients with low-grade malignancy (YK-2 or 3). BNR and BWR on the invasion front of the tongue cancer are predictors of pathological grade of malignancy and cervical lymph node metastasis.

  3. Exploring the benefit of synaesthetic colours: testing for "pop-out" in individuals with grapheme-colour synaesthesia.

    PubMed

    Rich, Anina N; Karstoft, Karen-Inge

    2013-01-01

    In grapheme-colour synaesthesia, letters, numbers, and words elicit involuntary colour experiences. Recently, there has been much emphasis on individual differences and possible subcategories of synaesthetes with different underlying mechanisms. In particular, there are claims that for some, synaesthesia occurs prior to attention and awareness of the inducing stimulus. We first characterized our sample using two versions of the "Synaesthetic Congruency Task" to distinguish "projector" and "associator" synaesthetes who may differ in the extent to which their synaesthesia depends on attention and awareness. We then used a novel modification of the "Embedded Figures Task" that included a set-size manipulation to look for evidence of preattentive "pop-out" from synaesthetic colours, at both a group and an individual level. We replicate an advantage for synaesthetes over nonsynaesthetic controls on the Embedded Figures Task in accuracy, but find no support for pop-out of synaesthetic colours. We conclude that grapheme-colour synaesthetes are fundamentally similar in their visual processing to the general population, with the source of their unusual conscious colour experiences occurring late in the cognitive hierarchy.

  4. Usefulness of B-mode and doppler sonography for the diagnosis of severe acute viral hepatitis A.

    PubMed

    Shin, Sang Wook; Kim, Tae Yeob; Jeong, Woo Kyoung; Kim, Yongsoo; Kim, Jinoo; Kim, Young Hwan; Park, Hwan Cheol; Sohn, Joo Hyun

    2015-01-01

    To investigate B-mode and Doppler ultrasonography (US) features correlating with laboratory findings for the diagnosis of severe acute hepatitis (SAH) in patients with hepatitis A virus infection. Thirty-nine consecutive serologically proven patients were enrolled. Decreased parenchymal echotexture, periportal tracking, gallbladder wall change, and splenomegaly were assessed on B-mode images. Blood flow velocities were measured in the main portal (V(PORTAL)) and in the hepatic veins, and the hepatic venous pulsatility index was calculated. SAH was defined as high model for end-stage liver disease (MELD) score ≥ 15 with or without coagulopathy. The relationship between US features and laboratory findings was assessed, and SAH diagnosis was evaluated. Serum alanine transaminase and prothrombin time were significantly different depending on the presence of gallbladder wall change and splenomegaly (p < 0.05). V(PORTAL) was inversely correlated with MELD score (r = -0.485) and several laboratory markers. The hepatic venous waveform and hepatic venous pulsatility index were significantly correlated with MELD score. For the diagnosis of SAH, the area under the receiver operating characteristic curve of V(PORTAL) was 0.798. It reached 0.869 in the patients with typical GB change. Both B-mode and Doppler US correlated well with several laboratory variables and may be helpful to diagnose SAH in patients with hepatitis A virus infection. © 2014 Wiley Periodicals, Inc.

  5. Colourful parrot feathers resist bacterial degradation

    PubMed Central

    Burtt, Edward H.; Schroeder, Max R.; Smith, Lauren A.; Sroka, Jenna E.; McGraw, Kevin J.

    2011-01-01

    The brilliant red, orange and yellow colours of parrot feathers are the product of psittacofulvins, which are synthetic pigments known only from parrots. Recent evidence suggests that some pigments in bird feathers function not just as colour generators, but also preserve plumage integrity by increasing the resistance of feather keratin to bacterial degradation. We exposed a variety of colourful parrot feathers to feather-degrading Bacillus licheniformis and found that feathers with red psittacofulvins degraded at about the same rate as those with melanin and more slowly than white feathers, which lack pigments. Blue feathers, in which colour is based on the microstructural arrangement of keratin, air and melanin granules, and green feathers, which combine structural blue with yellow psittacofulvins, degraded at a rate similar to that of red and black feathers. These differences in resistance to bacterial degradation of differently coloured feathers suggest that colour patterns within the Psittaciformes may have evolved to resist bacterial degradation, in addition to their role in communication and camouflage. PMID:20926430

  6. Laser-induced plasmonic colours on metals

    NASA Astrophysics Data System (ADS)

    Guay, Jean-Michel; Calà Lesina, Antonino; Côté, Guillaume; Charron, Martin; Poitras, Daniel; Ramunno, Lora; Berini, Pierre; Weck, Arnaud

    2017-07-01

    Plasmonic resonances in metallic nanoparticles have been used since antiquity to colour glasses. The use of metal nanostructures for surface colourization has attracted considerable interest following recent developments in plasmonics. However, current top-down colourization methods are not ideally suited to large-scale industrial applications. Here we use a bottom-up approach where picosecond laser pulses can produce a full palette of non-iridescent colours on silver, gold, copper and aluminium. We demonstrate the process on silver coins weighing up to 5 kg and bearing large topographic variations (~1.5 cm). We find that colours are related to a single parameter, the total accumulated fluence, making the process suitable for high-throughput industrial applications. Statistical image analyses of laser-irradiated surfaces reveal various nanoparticle size distributions. Large-scale finite-difference time-domain computations based on these nanoparticle distributions reproduce trends seen in reflectance measurements, and demonstrate the key role of plasmonic resonances in colour formation.

  7. Laser-induced plasmonic colours on metals

    PubMed Central

    Guay, Jean-Michel; Calà Lesina, Antonino; Côté, Guillaume; Charron, Martin; Poitras, Daniel; Ramunno, Lora; Berini, Pierre; Weck, Arnaud

    2017-01-01

    Plasmonic resonances in metallic nanoparticles have been used since antiquity to colour glasses. The use of metal nanostructures for surface colourization has attracted considerable interest following recent developments in plasmonics. However, current top-down colourization methods are not ideally suited to large-scale industrial applications. Here we use a bottom-up approach where picosecond laser pulses can produce a full palette of non-iridescent colours on silver, gold, copper and aluminium. We demonstrate the process on silver coins weighing up to 5 kg and bearing large topographic variations (∼1.5 cm). We find that colours are related to a single parameter, the total accumulated fluence, making the process suitable for high-throughput industrial applications. Statistical image analyses of laser-irradiated surfaces reveal various nanoparticle size distributions. Large-scale finite-difference time-domain computations based on these nanoparticle distributions reproduce trends seen in reflectance measurements, and demonstrate the key role of plasmonic resonances in colour formation. PMID:28719576

  8. Diagnostic utility of abdominal ultrasonography in dogs with chronic diarrhea.

    PubMed

    Leib, M S; Larson, M M; Grant, D C; Monroe, W E; Troy, G C; Panciera, D L; Rossmeisl, J H; Werre, S R

    2012-01-01

    Chronic diarrhea is common in dogs and has many causes. Ultrasonographic descriptions of many gastrointestinal diseases have been published, but the diagnostic utility of ultrasonography in dogs with chronic diarrhea has not been investigated. Diagnostic utility of abdominal ultrasound will be highest in dogs with GI neoplasia and lowest in those with inflammatory disorders. 87 pet dogs with chronic diarrhea. Prospective study in which medical records were reviewed and contribution of abdominal ultrasound toward making diagnosis was scored. In 57/87 (66%) of dogs, the same diagnosis would have been reached without ultrasonography. In 13/87 (15%) of dogs, the ultrasound examination was vital or beneficial to making the diagnosis. Univariable analysis identified that increased diagnostic utility was associated with weight loss (P = .0086), palpation of an abdominal or rectal mass (P = .0031), diseases that commonly have mass lesions visible on ultrasound examination (P < .0001), and a final diagnosis of GI neoplasia. Multivariable regression indicated that utility of abdominal ultrasonography would be 30 times more likely to be high in dogs in which an abdominal or rectal mass was palpated (odds ratio 30.5, 95% CI 5.5-169.6) (P < .0001) versus dogs without a palpable mass. In 15/87 (17%) of dogs, additional benefits of ultrasonography to case management, independent of the contribution to the diagnosis of diarrhea, were identified. Overall, the diagnostic utility of abdominal ultrasonography was low in dogs with chronic diarrhea. Identification of factors associated with high diagnostic utility is an indication to perform abdominal ultrasonography in dogs with chronic diarrhea. Copyright © 2012 by the American College of Veterinary Internal Medicine.

  9. Assessment of a prototype computer colour matching system to reproduce natural tooth colour on ceramic restorations.

    PubMed

    Kristiansen, Joshua; Sakai, Maiko; Da Silva, John D; Gil, Mindy; Ishikawa-Nagai, Shigemi

    2011-12-01

    The aim of this study was to assess the accuracy of a prototype computer colour matching (CCM) system for dental ceramics targeting the colour of natural maxillary central incisors employing a dental spectrophotometer and the Kubelka-Munk theory. Seventeen human volunteers with natural intact maxillary central incisors were selected to participate in this study. One central incisor from each subject was measured in the body region by a spectrophotometer and the reflectance values were used by the CCM system in order to generate a prescription for a ceramic mixture to reproduce the target tooth's colour. Ceramic discs were fabricated based on these prescriptions and layered on a zirconia ceramic core material of a specified colour. The colour match of each two-layered specimen to the target natural tooth was assessed by CIELAB colour coordinates (ΔE(*), ΔL(*), Δa(*) and Δb(*)). The average colour difference ΔE(*) value was 2.58±84 for the ceramic specimen-natural tooth (CS-NT) pairs. ΔL(*) values ranged from 0.17 to 2.71, Δa(*) values ranged from -1.70 to 0.61, and Δb(*) values ranged from -1.48 to 3.81. There was a moderate inverse correlation (R=-0.44, p-value=0.0721) between L(*) values for natural target teeth and ΔE(*) values; no such correlation was found for a(*) and b(*) values. The newly developed prototype CCM system has the potential to be used as an efficient tool in the reproduction of natural tooth colour. Copyright © 2011. Published by Elsevier Ltd.

  10. Retrospective comparison of abdominal ultrasonography and radiography in the investigation of feline abdominal disease

    PubMed Central

    Won, Wylen Wade; Sharma, Ajay; Wu, Wenbo

    2015-01-01

    Abdominal radiography and ultrasonography are commonly used as part of the initial diagnostic plan for cats with nonspecific signs of abdominal disease. This retrospective study compared the clinical usefulness of abdominal radiography and ultrasonography in 105 feline patients with signs of abdominal disease. The final diagnosis was determined more commonly with ultrasonography (59%) compared to radiography (25.7%). Ultrasonography was also able to provide additional clinically relevant information in 76% of cases, and changed or refined the diagnosis in 47% of cases. Based on these findings, ultrasonography may be sufficient as an initial diagnostic test for the investigation of feline abdominal disease. PMID:26483582

  11. Teaching of clinical ultrasonography to undergraduates: students as mentors.

    PubMed

    García de Casasola Sánchez, G; González Peinado, D; Sánchez Gollarte, A; Muñoz Aceituno, E; Peña Vázquez, I; Torres Macho, J

    2015-05-01

    Ultrasonography is a highly useful diagnostic technique that supplements traditional physical examinations. To demonstrate that students previously trained in clinical ultrasonography are capable of instructing other students in a similar manner in a short period of time ("peer mentoring"). Five medical students in their 5th year, trained in abdominal and cardiac ultrasonography by physicians with experience, instructed 24 other students in the same procedure. The training consisted of an online theoretical course and practical training lasting about 12hours, in which each student had to perform 6 basic abdominal planes and 4 basic cardiac planes on 20 healthy volunteers. Subsequently, the students underwent an objective assessment test on healthy models performed by expert physicians in clinical ultrasonography. The students managed to correctly identify 90.2% of the basic abdominal planes, except for the left coronal (spleen and left kidney) and subcostal (gallbladder) planes, with slightly lower success rates of 82.5% and 80%, respectively. Due to the greater difficulty of obtaining cardiac planes, the success rate was lower: 70.3%, in the subxiphoid, short parasternal and four chamber planes. The cardiac plane with the fewest errors in identification was the parasternal long plane (90% success). We observed no statistically significant differences between the results (teaching capacity) of the various mentors. Medical students are capable of instructing other colleagues (peer mentoring) on the basic aspects of abdominal and cardiac ultrasonography after a relatively short training period. Copyright © 2014 Elsevier España, S.L.U. y Sociedad Española de Medicina Interna (SEMI). All rights reserved.

  12. Human colour in mate choice and competition.

    PubMed

    Rowland, Hannah M; Burriss, Robert P

    2017-07-05

    The colour of our skin and clothing affects how others perceive us and how we behave. Human skin colour varies conspicuously with genetic ancestry, but even subtle changes in skin colour due to diet, blood oxygenation and hormone levels influence social perceptions. In this review, we describe the theoretical and empirical frameworks in which human colour is researched. We explore how subtle skin colour differences relate to judgements of health and attractiveness. Also, because humans are one of the few organisms able to manipulate their apparent colour, we review how cosmetics and clothing are implicated in courtship and competition, both inside the laboratory and in the real world. Research on human colour is in its infancy compared with human psychophysics and colour research in non-human animals, and hence we present best-practice guidelines for methods and reporting, which we hope will improve the validity and reproducibility of studies on human coloration.This article is part of the themed issue 'Animal coloration: production, perception, function and application'. © 2017 The Author(s).

  13. An RGB Approach to Prismatic Colours

    ERIC Educational Resources Information Center

    Theilmann, Florian; Grusche, Sascha

    2013-01-01

    Teaching prismatic colours usually boils down to establishing the take-home message that white light consists of "differently refrangible" coloured rays. This approach explains the classical spectrum of seven colours but has its limitations, e.g. in discussing spectra from setups with higher resolution or in understanding the well…

  14. Skin colour typology and suntanning pathways.

    PubMed

    Chardon, A; Cretois, I; Hourseau, C

    1991-08-01

    Synopsis The evaluation of sun-product efficacy, with laboratory solar simulators or in actual sun, implicates clinical and subjective assessment of the various skin responses in terms of wavelengths constitutive of solar light. These photobiological responses vary according to skin types and particularly to basic skin melanic content, i.e. with skin colour. Now, the instrumental measurement of live skin colour has become easier to perform, fast and reliable. Based on the standard CIE-L*a*b* colour system and correlated with the human eye, this technique was used to define the skin colour domain of the caucasian population, to propose a skin colour classification, and then to objectively follow, over a three week period, the dynamics and kinetics of tanning induced by UVB, UVA and UVB +/- A multi-exposures on the three skin categories. The specific directions in the three-dimensional L*a*b* colour space of the tanning components, i.e. erythema, immediate pigmentation and constitutional melanization, as well as the resulting tanning pathways, were analysed and defined in the three-dimensional colour space, using a vectorial method. The UVB, UVA and UVB +/- A tannings were differentiated by their intensity, their hue and especially their lasting capacity: UVA tanning clearly appeared more lasting than UVB. In addition, the UVA*UVB interaction on tanning intensity was not found to be significant. With the skin colour classification and the tanning models, this comprehensive study supplies a basic tool for the colorimetric interpretation of the skin phenomena involved, provided that this interpretation is always considered in the three dimensions of the colour space. It also suggests some useful practical applications for sun product formulation and evaluation.

  15. Colour thresholds in a coral reef fish

    PubMed Central

    Vorobyev, M.; Marshall, N. J.

    2016-01-01

    Coral reef fishes are among the most colourful animals in the world. Given the diversity of lifestyles and habitats on the reef, it is probable that in many instances coloration is a compromise between crypsis and communication. However, human observation of this coloration is biased by our primate visual system. Most animals have visual systems that are ‘tuned’ differently to humans; optimized for different parts of the visible spectrum. To understand reef fish colours, we need to reconstruct the appearance of colourful patterns and backgrounds as they are seen through the eyes of fish. Here, the coral reef associated triggerfish, Rhinecanthus aculeatus, was tested behaviourally to determine the limits of its colour vision. This is the first demonstration of behavioural colour discrimination thresholds in a coral reef species and is a critical step in our understanding of communication and speciation in this vibrant colourful habitat. Fish were trained to discriminate between a reward colour stimulus and series of non-reward colour stimuli and the discrimination thresholds were found to correspond well with predictions based on the receptor noise limited visual model and anatomy of the eye. Colour discrimination abilities of both reef fish and a variety of animals can therefore now be predicted using the parameters described here. PMID:27703704

  16. Linear array ultrasonography to stage rectal neoplasias suitable for local treatment.

    PubMed

    Ravizza, Davide; Tamayo, Darina; Fiori, Giancarla; Trovato, Cristina; De Roberto, Giuseppe; de Leone, Annalisa; Crosta, Cristiano

    2011-08-01

    Because of the many therapeutic options available, a reliable staging is crucial for rectal neoplasia management. Adenomas and cancers limited to the submucosa without lymph node involvement may be treated locally. The aim of this study is to evaluate the diagnostic accuracy of endorectal ultrasonography in the staging of neoplasias suitable for local treatment. We considered all patients who underwent endorectal ultrasonography between 2001 and 2010. The study population consisted of 92 patients with 92 neoplasias (68 adenocarcinomas and 24 adenomas). A 5 and 7.5MHz linear array echoendoscope was used. The postoperative histopathologic result was compared with the preoperative staging defined by endorectal ultrasonography. Adenomas and cancers limited to the submucosa were considered together (pT0-1). The sensitivity, specificity, overall accuracy rate, positive predictive value, and negative predictive value of endorectal ultrasonography for pT0-1 were 86%, 95.6%, 91.3%, 94.9% and 88.7%. Those for nodal involvement were 45.4%, 95.5%, 83%, 76.9% and 84%, with 3 false positive results and 12 false negative. For combined pT0-1 and pN0, endorectal ultrasonography showed an 87.5% sensitivity, 95.9% specificity, 92% overall accuracy rate, 94.9% positive predictive value and 90.2% negative predictive value. Endorectal linear array ultrasonography is a reliable tool to detect rectal neoplasias suitable for local treatment. Copyright © 2011 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.

  17. Changes in ultrasonography indicators of abnormally invasive placenta during pregnancy.

    PubMed

    Calì, Giuseppe; Timor-Trisch, Ilan E; Palacios-Jaraquemada, Josè; Monteaugudo, Ana; Forlani, Francesco; Minneci, Gabriella; Foti, Francesca; Buca, Danilo; Familiari, Alessandra; Scambia, Giovanni; Liberati, Marco; D'Antonio, Francesco

    2018-03-01

    To ascertain whether the prevalence of ultrasonography signs of abnormally invasive placenta (AIP) changes during pregnancy. The present retrospective analysis included women with a prenatal diagnosis of AIP that was confirmed at delivery between January 1, 2007, and April 30, 2017, at the Department of Obstetrics and Gynaecology, Arnas Civico Hospital, Palermo, Italy. Ultrasonography signs of AIP were recorded at four different intervals during pregnancy: early first (6-9 weeks), first (11-14 weeks), second (15-24 weeks), and third trimester (25-36 weeks). There were 105 pregnancies included. Low implantation of the gestational sac was present on all ultrasonography images from the early first trimester compared with on 23 of 83 (27.7%) images from 11-14 weeks of pregnancy. The identification of loss of the clear space, placental lacunae, bladder wall interruption, and uterovesical hypervascularity all increased (all P<0.001) from the early first trimester onwards; these could all be identified in a majority of patients at 11-14 weeks of pregnancy. The prevalence of ultrasonography signs suggestive of AIP varied throughout pregnancy. During the early first trimester, indicators of AIP were similar to those of a cesarean scar pregnancy; classical ultrasonography signs of AIP were already present at 11-14 weeks of pregnancy for most patients. © 2017 International Federation of Gynecology and Obstetrics.

  18. NICE: A Computational Solution to Close the Gap from Colour Perception to Colour Categorization

    PubMed Central

    Parraga, C. Alejandro; Akbarinia, Arash

    2016-01-01

    The segmentation of visible electromagnetic radiation into chromatic categories by the human visual system has been extensively studied from a perceptual point of view, resulting in several colour appearance models. However, there is currently a void when it comes to relate these results to the physiological mechanisms that are known to shape the pre-cortical and cortical visual pathway. This work intends to begin to fill this void by proposing a new physiologically plausible model of colour categorization based on Neural Isoresponsive Colour Ellipsoids (NICE) in the cone-contrast space defined by the main directions of the visual signals entering the visual cortex. The model was adjusted to fit psychophysical measures that concentrate on the categorical boundaries and are consistent with the ellipsoidal isoresponse surfaces of visual cortical neurons. By revealing the shape of such categorical colour regions, our measures allow for a more precise and parsimonious description, connecting well-known early visual processing mechanisms to the less understood phenomenon of colour categorization. To test the feasibility of our method we applied it to exemplary images and a popular ground-truth chart obtaining labelling results that are better than those of current state-of-the-art algorithms. PMID:26954691

  19. NICE: A Computational Solution to Close the Gap from Colour Perception to Colour Categorization.

    PubMed

    Parraga, C Alejandro; Akbarinia, Arash

    2016-01-01

    The segmentation of visible electromagnetic radiation into chromatic categories by the human visual system has been extensively studied from a perceptual point of view, resulting in several colour appearance models. However, there is currently a void when it comes to relate these results to the physiological mechanisms that are known to shape the pre-cortical and cortical visual pathway. This work intends to begin to fill this void by proposing a new physiologically plausible model of colour categorization based on Neural Isoresponsive Colour Ellipsoids (NICE) in the cone-contrast space defined by the main directions of the visual signals entering the visual cortex. The model was adjusted to fit psychophysical measures that concentrate on the categorical boundaries and are consistent with the ellipsoidal isoresponse surfaces of visual cortical neurons. By revealing the shape of such categorical colour regions, our measures allow for a more precise and parsimonious description, connecting well-known early visual processing mechanisms to the less understood phenomenon of colour categorization. To test the feasibility of our method we applied it to exemplary images and a popular ground-truth chart obtaining labelling results that are better than those of current state-of-the-art algorithms.

  20. Laser Doppler diagnostics for orthodontia

    NASA Astrophysics Data System (ADS)

    Ryzhkova, Anastasia V.; Lebedeva, Nina G.; Sedykh, Alexey V.; Ulyanov, Sergey S.; Lepilin, Alexander V.; Kharish, Natalia A.

    2004-06-01

    The results of statistical analysis of Doppler spectra of intensity fluctuations of light, scattered from mucous membrane of oral cavity of healthy volunteers and patients, abused by the orthodontic diseases, are presented. Analysis of Doppler spectra, obtained from tooth pulp of patients, is carried out. New approach to monitoring of blood microcirculation in orthodontics is suggested. Influence of own noise of Doppler measuring system on formation of the output signal is studied.

  1. Encapsulated Papillary Carcinoma in A Man with Gynecomastia: Ultrasonography, Mammography and Magnetic Resonance Imaging Features with Pathologic Correlation.

    PubMed

    Yılmaz, Ravza; Cömert, Rana Günöz; Aliyev, Samil; Toktaş, Yücel; Önder, Semen; Emirikçi, Selman; Özmen, Vahit

    2018-04-01

    Male breast cancer is an uncommon disease that constitutes 1% of all breast cancers and encapsulated papillary carcinoma (EPC) is a rare subtype of malignant male diseases. Gynecomastia is the most common disease of the male breast. We report a 63-year-old male patient with EPC accompanied by gynecomastia that was diagnosed and treated at our breast center. Mammography showed an oval-shaped dense mass with circumscribed margins on the ground of nodular gynecomastia. On ultrasonographic exam, we saw a well-circumscribed complex mass with a solid component which was vascular on Doppler ultrasonography. Magnetic resonance imaging revealed a complex cystic mass containing solid components. Dynamic images showed enhancement of the cystic mass wall and mural components. Tumor stage was evaluated as T2N0. The lesion's histologic examination and immunohistochemical analysis by showing no myoepithelial layer revealed an encapsulated papillary carcinoma. To our knowledge, this is the first case report which describes MR imaging findings of male breast encapsulated papillary cancer.

  2. The Efficacy of Thoracic Ultrasonography in Postoperative Newborn Patients after Cardiac Surgery

    PubMed Central

    Ozturk, Erkut; Tanidir, Ibrahim Cansaran; Yildiz, Okan; Ergul, Yakup; Guzeltas, Alper

    2017-01-01

    Objective In this study, the efficacy of thoracic ultrasonography during echocardiography was evaluated in newborns. Methods Sixty newborns who had undergone pediatric cardiac surgery were successively evaluated between March 1, 2015, and September 1, 2015. Patients were evaluated for effusion, pulmonary atelectasis, and pneumothorax by ultrasonography, and results were compared with X-ray findings. Results Sixty percent (n=42) of the cases were male, the median age was 14 days (2-30 days), and the median body weight was 3.3 kg (2.8-4.5 kg). The median RACHS-1 score was 4 (2-6). Atelectasis was demonstrated in 66% (n=40) of the cases. Five of them were determined solely by X-ray, 10 of them only by ultrasonography, and 25 of them by both ultrasonography and X-ray. Pneumothorax was determined in 20% (n=12) of the cases. Excluding one case determined by both methods, all of the 11 cases were diagnosed by X-ray. Pleural effusion was diagnosed in 26% (n=16) of the cases. Four of the cases were demonstrated solely by ultrasonography, three of them solely by X-ray, and nine of the cases by both methods. Pericardial effusion was demonstrated in 10% (n=6) of the cases. Except for one of the cases determined by both methods, five of the cases were diagnosed by ultrasonography. There was a moderate correlation when all pathologies evaluated together (k=0.51). Conclusion Thoracic ultrasonography might be a beneficial non-invasive method to evaluate postoperative respiratory problems in newborns who had congenital cardiac surgery. PMID:28977200

  3. The effect of colour on children's cognitive performance.

    PubMed

    Brooker, Alice; Franklin, Anna

    2016-06-01

    The presence of red appears to hamper adults' cognitive performance relative to other colours (see Elliot & Maier, 2014, Ann. Rev. Psychol. 65, 95). Here, we investigate whether colour affects cognitive performance in 8- and 9-year-olds. Children completed a battery of tasks once in the presence of a coloured screen that was one of eight colours and once in the presence of a grey screen. Performance was assessed for each colour relative to the grey baseline, and differences across colours were compared. We find a significant difference in performance across colours, with significantly worse performance in the presence of red than grey. The effect of colour did not significantly interact with task. The findings suggest that colour can affect children's cognitive performance and that there is a detrimental effect of red. Findings are related to the adult literature and implications for educational contexts are discussed. © 2015 The British Psychological Society.

  4. Colour discrimination and categorisation in Williams syndrome.

    PubMed

    Farran, Emily K; Cranwell, Matthew B; Alvarez, James; Franklin, Anna

    2013-10-01

    Individuals with Williams syndrome (WS) present with impaired functioning of the dorsal visual stream relative to the ventral visual stream. As such, little attention has been given to ventral stream functions in WS. We investigated colour processing, a predominantly ventral stream function, for the first time in nineteen individuals with Williams syndrome. Colour discrimination was assessed using the Farnsworth-Munsell 100 hue test. Colour categorisation was assessed using a match-to-sample test and a colour naming task. A visual search task was also included as a measure of sensitivity to the size of perceptual colour difference. Results showed that individuals with WS have reduced colour discrimination relative to typically developing participants matched for chronological age; performance was commensurate with a typically developing group matched for non-verbal ability. In contrast, categorisation was typical in WS, although there was some evidence that sensitivity to the size of perceptual colour differences was reduced in this group. Copyright © 2013 Elsevier Ltd. All rights reserved.

  5. Balancing selection maintains cryptic colour morphs.

    PubMed

    Wellenreuther, Maren

    2017-11-01

    Animals display incredibly diverse colour patterns, a testament to evolution's endless innovation in shaping life. In many species, the interplay between males and females in the pursuit of mates has driven the evolution of a myriad of colour forms, from the flashy peacock tail feathers to the tiniest colour markings in damselflies. In others, colour provides crypsis by allowing to blend into the background and to escape the eyes of predators. While the obvious benefits of this dazzling diversity for reproduction and survival seem straightforward, its maintenance is not. Theory predicts that genetic drift and various forms of selection reduce variation over time, making the persistence of colour variants over generations a puzzle. In this issue of Molecular Ecology, Lindtke et al. () study the cryptic colour morphs of Timema cristinae walking sticks to shed light on the genetic architecture and mechanisms that allow colour polymorphism maintenance over long timescales. By combining genome-wide data with phenotyping information from natural populations, they were able to map the green and melanistic colour to one genomic region with highly reduced effective recombination rate between two main chromosomal variants, consistent with an inversion polymorphism. These two main chromosomal variants showed geographically widespread heterozygote excess, and genomic signatures consistent with long-term balancing selection. A younger chromosomal variant was detected for the third morph, the green-striped colour morphs, in the same genomic regions as the melanistic and the green-unstriped morphs. Together, these results suggest that the genetic architecture of cryptic T. cristinae morphs is caused by nonrecombining genomic blocks that have been maintained over extended time periods by balancing selection making this study one of the few available empirical examples documenting that balancing selection of various forms may play an important role in maintaining adaptive genetic

  6. Screening ultrasonography of 2,204 patients with blunt abdominal trauma in the Wenchuan earthquake.

    PubMed

    Zhou, Jixiang; Huang, Jiwei; Wu, Hong; Jiang, Hui; Zhang, Heqing; Prasoon, Pankaj; Xu, Yinglong; Bai, Yannan; Qiu, Jianguo; Zeng, Yong

    2012-10-01

    Abdominal injuries constitute a small proportion of all earthquake-related traumas; however, it often resulted in fatal hemorrhage. Ultrasonography has been described as an effective triage tool in the evaluation of blunt abdominal trauma. We aimed to present an overview of the diagnostic accuracy of screening ultrasonography for patients with blunt abdominal trauma admitted to various hospitals during the Wenchuan earthquake in China. We retrospectively analyzed the patients with blunt abdominal trauma who underwent ultrasonography after admission to various hospitals. Ultrasonography findings were considered positive if evidence of free fluid or a parenchymal injury was identified. Ultrasonography findings were compared with the findings of computed tomography, diagnostic peritoneal lavage, repeated ultrasonography, cystography, operation, and/or the clinical course. Findings from 2,204 ultrasonographic examinations were evaluated. Findings of 199 ultrasonographic examinations (9.0%) were considered positive. Of the patients, 12 (0.5%) had a false-negative ultrasonographic findings; of this group, 3 (25%) required exploratory laparotomy. Ultrasonography had a sensitivity of 91.9%, specificity of 96.9%, and an accuracy of 96.6% for detection of abdominal injuries. Positive predictive value was 68.3%, and negative predictive value was 99.4%. Screening ultrasonography is highly reliable in the setting of blunt abdominal trauma after earthquake. It should be used as an initial diagnostic modality in the evaluation of most blunt abdominal trauma. Diagnostic study, level III.

  7. Colour Vision Deficiency and Physics Teaching

    ERIC Educational Resources Information Center

    Maule, Louise; Featonby, David

    2016-01-01

    1 in 12 males suffer from some form of colour vision deficiency (CVD) which in the present colour dominated world of education presentation can be a severe disadvantage. Although aware of "colourblindness" most teachers make little or no adjustment for these pupils for whom tasks may be more difficult. This article examines colour vision…

  8. Doppler-guided retrograde catheterization system

    NASA Astrophysics Data System (ADS)

    Frazin, Leon J.; Vonesh, Michael J.; Chandran, Krishnan B.; Khasho, Fouad; Lanza, George M.; Talano, James V.; McPherson, David D.

    1991-05-01

    The purpose of this study was to investigate a Doppler guided catheterization system as an adjunctive or alternative methodology to overcome the disadvantages of left heart catheterization and angiography. These disadvantages include the biological effects of radiation and the toxic and volume effects of iodine contrast. Doppler retrograde guidance uses a 20 MHz circular pulsed Doppler crystal incorporated into the tip of a triple lumen multipurpose catheter and is advanced retrogradely using the directional flow information provided by the Doppler waveform. The velocity detection limits are either 1 m/second or 4 m/second depending upon the instrumentation. In a physiologic flow model of the human aortic arch, multiple data points revealed a positive wave form when flow was traveling toward the catheter tip indicating proper alignment for retrograde advancement. There was a negative wave form when flow was traveling away from the catheter tip if the catheter was in a branch or bent upon itself indicating improper catheter tip position for retrograde advancement. In a series of six dogs, the catheter was able to be accurately advanced from the femoral artery to the left ventricular chamber under Doppler signal guidance without the use of x-ray. The potential applications of a Doppler guided retrograde catheterization system include decreasing time requirements and allowing safer catheter guidance in patients with atherosclerotic vascular disease and suspected aortic dissection. The Doppler system may allow left ventricular pressure monitoring in the intensive care unit without the need for x-ray and it may allow left sided contrast echocardiography. With pulse velocity detection limits of 4 m/second, this system may allow catheter direction and passage into the aortic root and left ventricle in patients with aortic stenosis. A modification of the Doppler catheter may include transponder technology which would allow precise catheter tip localization once the

  9. Field-portable pixel super-resolution colour microscope.

    PubMed

    Greenbaum, Alon; Akbari, Najva; Feizi, Alborz; Luo, Wei; Ozcan, Aydogan

    2013-01-01

    Based on partially-coherent digital in-line holography, we report a field-portable microscope that can render lensfree colour images over a wide field-of-view of e.g., >20 mm(2). This computational holographic microscope weighs less than 145 grams with dimensions smaller than 17×6×5 cm, making it especially suitable for field settings and point-of-care use. In this lensfree imaging design, we merged a colorization algorithm with a source shifting based multi-height pixel super-resolution technique to mitigate 'rainbow' like colour artefacts that are typical in holographic imaging. This image processing scheme is based on transforming the colour components of an RGB image into YUV colour space, which separates colour information from brightness component of an image. The resolution of our super-resolution colour microscope was characterized using a USAF test chart to confirm sub-micron spatial resolution, even for reconstructions that employ multi-height phase recovery to handle dense and connected objects. To further demonstrate the performance of this colour microscope Papanicolaou (Pap) smears were also successfully imaged. This field-portable and wide-field computational colour microscope could be useful for tele-medicine applications in resource poor settings.

  10. A review of tooth colour and whiteness.

    PubMed

    Joiner, Andrew; Hopkinson, Ian; Deng, Yan; Westland, Stephen

    2008-01-01

    To review current knowledge on the definition of tooth whiteness and its application within dentistry, together with the measured range of tooth colours. 'Medline' and 'ISI Web of Sciences' databases were searched electronically with key words tooth, teeth, colour, colour, white and whiteness. The application of colour science within dentistry has permitted the measurement of tooth colour in an objective way, with the most common colour space in current use being the CIELAB (Commission Internationale de l'Eclairage). Indeed, many investigators from a range of different countries have reported L*, a* and b* values for teeth measured in vivo using instrumental techniques such as spectrophotometers, colorimeters and image analysis of digital images. In general, these studies show a large range in L*, a* and b* values, but consistently show that there is a significant contribution of b* value or yellowness in natural tooth colour. Further developments in colour science have lead to the description of tooth whiteness and changes in tooth whiteness based on whiteness indices, with the most relevant and applicable being the WIO whiteness index, a modified version of the CIE whiteness index.

  11. Assessment of placental volume and vascularization at 11-14 weeks of gestation in a Taiwanese population using three-dimensional power Doppler ultrasound.

    PubMed

    Wang, Hsing-I; Yang, Ming-Jie; Wang, Peng-Hui; Wu, Yi-Cheng; Chen, Chih-Yao

    2014-12-01

    The placental volume and vascular indices are crucial in helping doctors to evaluate early fetal growth and development. Inadequate placental volume or vascularity might indicate poor fetal growth or gestational complications. This study aimed to evaluate the placental volume and vascular indices during the period of 11-14 weeks of gestation in a Taiwanese population. From June 2006 to September 2009, three-dimensional power Doppler ultrasound was performed in 222 normal pregnancies from 11-14 weeks of gestation. Power Doppler ultrasound was applied to the placenta and the placental volume was obtained by a rotational technique (VOCAL). The three-dimensional power histogram was used to assess the placental vascular indices, including the mean gray value, the vascularization index, the flow index, and the vascularization flow index. The placental vascular indices were then plotted against gestational age (GA) and placental volume. Our results showed that the linear regression equation for placental volume using gestational week as the independent variable was placental volume = 18.852 × GA - 180.89 (r = 0.481, p < 0.05). All the placental vascular indices showed a constant distribution throughout the period 11-14 weeks of gestation. A tendency for a reduction in the placental mean gray value with gestational week was observed, but without statistical significance. All the placental vascular indices estimated by three-dimensional power Doppler ultrasonography showed a constant distribution throughout gestation. Copyright © 2014. Published by Elsevier Taiwan.

  12. Counting with Colours? Effect of Colours on the Numerical Abilities of House Crows (Corvus splendens) and Common Myna (Acridotheres tristis).

    PubMed

    Rahman, Nor Amira Abdul; Ali, Zalila; Zuharah, Wan Fatma; Fadzly, Nik

    2016-08-01

    We conducted several aviary experiments to investigate the influence of colours in quantity judgments of two species of birds; house crow (Corvus splendens) and common myna (Acridotheres tristis). Different quantity (in seven different food proportions) of mealworms were presented nonsequentially to all birds using artificially coloured red mealworms, for experiment 1, and using artificially coloured green mealworms, for experiment 2. Both red and green coloured mealworms have no significant effect on house crow's quantity judgments (red: F6,30 = 1.748, p = 0.144; and green: F6,30= 1.085, p = 0.394). Common myna, however, showed a strong influence of red colour in their quantity judgment ( F6,30 = 2.922, p = 0.023) as they succeeded in choosing the largest amount of food between two cups, but not when offered food using green coloured mealworms ( F6,30 = 1.183, p = 0.342). In the next experiment, we hypothesised that both house crow and common myna will prefer red coloured food items over green coloured food items, when factors such as the amount of food is equal. We chose to test red and green colours because both colours play an important role in most avian food selections. Results showed that there were no significant differences in the selection of red or green coloured mealworms for both house crows ( F6,30 = 2.310, p = 0.06) and common myna ( F6,30 = 0.823, p = 0.561).

  13. The colour wheels of art, perception, science and physiology

    NASA Astrophysics Data System (ADS)

    Harkness, Nick

    2006-06-01

    Colour is not the domain of any one discipline be it art, philosophy, psychology or science. Each discipline has its own colour wheel and this presentation examines the origins and philosophies behind the colour circles of Art, Perception, Science and Physiology (after image) with reference to Aristotle, Robert Boyle, Leonardo da Vinci, Goethe, Ewald Hering and Albert Munsell. The paper analyses and discusses the differences between the four colour wheels using the Natural Colour System® notation as the reference for hue (the position of colours within each of the colour wheels). Examination of the colour wheels shows the dominance of blue in the wheels of art, science and physiology particularly at the expense of green. This paper does not consider the three-dimensionality of colour space its goal was to review the hue of a colour with regard to its position on the respective colour wheels.

  14. Occupational colour vision requirements for police officers.

    PubMed

    Birch, Jennifer; Chisholm, Catharine M

    2008-11-01

    Inclusion of public service professions in the UK Disability Discrimination Act in 2004 prompted a review of occupational colour vision requirements for police officers. Changes in the regulations which existed prior to 2003 were proposed. The aim of this study was to obtain the views of serving police officers in Northern Ireland on the importance of good colour discrimination in everyday police work and on the recruitment regulations for patrol constables introduced in 2003 in mainland UK. These views were obtained by means of a questionnaire and informal discussions. More than 65% of police officers who responded to the questionnaire considered that good colour vision was very important for effective policing. Fewer than 2% considered that colour vision was unimportant. Experienced police officers agreed that the employment of colour-deficient patrol constables, as permitted in the new regulations, would lead to reduced efficiency and organisational difficulties at the local level. A number of everyday activities were described which showed the need for accurate colour discrimination. The change in recruitment policy and the lack of clarity in the new regulations show inadequate appreciation of the needs of the occupation, of different types of colour vision anomalies and of the diagnostic function of colour vision tests. Failure to provide guidance on appropriate colour vision tests, examination procedures and counselling services is likely to result in inconsistent employment policies in different police forces. It is recommended that the colour vision standard in place prior to 2003 is reinstated at the recruitment stage. The Ishihara test should be used for screening, and colour-deficient applicants further examined with the Farnsworth D15 test as a replacement for the City University Test 2nd edition.

  15. Colour-specific differences in attentional deployment for equiluminant pop-out colours: evidence from lateralised potentials.

    PubMed

    Pomerleau, Vincent Jetté; Fortier-Gauthier, Ulysse; Corriveau, Isabelle; Dell'Acqua, Roberto; Jolicœur, Pierre

    2014-03-01

    We investigated how target colour affected behavioural and electrophysiological results in a visual search task. Perceptual and attentional mechanisms were tracked using the N2pc component of the event-related potential and other lateralised components. Four colours (red, green, blue, or yellow) were calibrated for each participant for luminance through heterochromatic flicker photometry and equated to the luminance of grey distracters. Each visual display contained 10 circles, 1 colored and 9 grey, each of which contained an oriented line segment. The task required deploying attention to the colored circle, which was either in the left or right visual hemifield. Three lateralised ERP components relative to the side of the lateral coloured circle were examined: a posterior contralateral positivity (Ppc) prior to N2pc, the N2pc, reflecting the deployment of visual spatial attention, and a temporal and contralateral positivity (Ptc) following N2pc. Red or blue stimuli, as compared to green or yellow, had an earlier N2pc. Both the Ppc and Ptc had higher amplitudes to red stimuli, suggesting particular selectivity for red. The results suggest that attention may be deployed to red and blue more quickly than to other colours and suggests special caution when designing ERP experiments involving stimuli in different colours, even when all colours are equiluminant. Copyright © 2013 Elsevier B.V. All rights reserved.

  16. Relationship between consumer ranking of lamb colour and objective measures of colour.

    PubMed

    Khliji, S; van de Ven, R; Lamb, T A; Lanza, M; Hopkins, D L

    2010-06-01

    Given the lack of data that relates consumer acceptance of lamb colour to instrument measures a study was undertaken to establish the acceptability thresholds for fresh and displayed meat. Consumers (n=541) were asked to score 20 samples of lamb loin (m.longissimus thoracis et lumborum; LL) on an ordinal scale of 1 (very acceptable) to 5 (very unacceptable). A sample was considered acceptable by a consumer if it scored three or less. Ten samples were used for testing consumer response to fresh colour and 10 to test consumer response to colour during display of up to 4days. The colour of fresh meat was measured using a Minolta chromameter with a closed cone and a Hunter Lab Miniscan was used for measuring meat on display. For fresh meat when the a( *) (redness) and L( *) (lightness) values are equal to or exceed 9.5 and 34, respectively, on average consumers will consider the meat colour acceptable. However a( *) and L( *) values must be much higher (14.5 and 44, respectively) to have 95% confidence that a randomly selected consumer will consider a sample acceptable. For aged meat, when the wavelength ratio (630/580nm) and the a( *) values are equal to or greater than 3.3 and 14.8, respectively, on average consumers will consider the meat acceptable. These thresholds need to be increased to 6.8 for ratio (630/580nm) and 21.7 for a( *) to be 95% confident that a randomly selected consumer will consider a sample acceptable. Crown Copyright 2010. Published by Elsevier Ltd. All rights reserved.

  17. The diagnosis of neonatal pulmonary atelectasis using lung ultrasonography.

    PubMed

    Liu, Jing; Chen, Shui-Wen; Liu, Fang; Li, Qiu-Ping; Kong, Xiang-Yong; Feng, Zhi-Chun

    2015-04-01

    Ultrasonography has been used for the diagnosis of many kinds of lung conditions, but few studies have investigated ultrasound for the diagnosis of neonatal pulmonary atelectasis (NAP). In this study, we evaluated the usefulness of lung ultrasonography for the diagnosis of NPA. From May 2012 to December 2013, 80 neonates with NPA and 50 neonates without lung disease were enrolled in this study. Each lung of every infant was divided into the anterior, lateral, and posterior regions by the anterior and posterior axillary lines. Each region was scanned carefully with the probe perpendicular or parallel to the ribs. The ultrasound findings were confirmed by chest radiograph (CXR) or CT scan. Sixty of the 80 patients with signs of NPA on lung ultrasound also had signs of NPA on CXR (termed focal-type atelectasis), and the other 20 patients had signs of NPA on chest CT scan while there were no abnormal findings on CXR (termed occult lung atelectasis). In patients with NPA, the main ultrasound findings were large areas of lung consolidation with clearly demarcated borders, air bronchograms, pleural line abnormalities, and absence of A-lines, as well as the presence of lung pulse and absence of lung sliding on real-time ultrasound. The sensitivity of lung ultrasonography for the diagnosis of NPA was 100%, whereas the sensitivity of CXR was 75%. Large areas of lung consolidation with clearly demarcated borders were only observed in patients with NPA. Lung ultrasonography is an accurate and reliable method for diagnosing NPA; most importantly, it can find those occult lung atelectasis that could not be detected on CXR. Routine lung ultrasonography is a useful method of diagnosing or excluding NPA in neonates.

  18. Another look at category effects on colour perception and their left hemispheric lateralisation: no evidence from a colour identification task.

    PubMed

    Suegami, Takashi; Aminihajibashi, Samira; Laeng, Bruno

    2014-05-01

    The present study aimed to replicate category effects on colour perception and their lateralisation to the left cerebral hemisphere (LH). Previous evidence for lateralisation of colour category effects has been obtained with tasks where a differently coloured target was searched within a display and participants reported the lateral location of the target. However, a left/right spatial judgment may yield LH-laterality effects per se. Thus, we employed an identification task that does not require a spatial judgment and used the same colour set that previously revealed LH-lateralised category effects. The identification task was better performed with between-category colours than with within-category task both in terms of accuracy and latency, but such category effects were bilateral or RH-lateralised, and no evidence was found for LH-laterality effects. The accuracy scores, moreover, indicated that the category effects derived from low sensitivities for within-blue colours and did not reflect the effects of categorical structures on colour perception. Furthermore, the classic "category effects" were observed in participants' response biases, instead of sensitivities. The present results argue against both the LH-lateralised category effects on colour perception and the existence of colour category effects per se.

  19. The Novel Nonlinear Adaptive Doppler Shift Estimation Technique and the Coherent Doppler Lidar System Validation Lidar

    NASA Technical Reports Server (NTRS)

    Beyon, Jeffrey Y.; Koch, Grady J.

    2006-01-01

    The signal processing aspect of a 2-m wavelength coherent Doppler lidar system under development at NASA Langley Research Center in Virginia is investigated in this paper. The lidar system is named VALIDAR (validation lidar) and its signal processing program estimates and displays various wind parameters in real-time as data acquisition occurs. The goal is to improve the quality of the current estimates such as power, Doppler shift, wind speed, and wind direction, especially in low signal-to-noise-ratio (SNR) regime. A novel Nonlinear Adaptive Doppler Shift Estimation Technique (NADSET) is developed on such behalf and its performance is analyzed using the wind data acquired over a long period of time by VALIDAR. The quality of Doppler shift and power estimations by conventional Fourier-transform-based spectrum estimation methods deteriorates rapidly as SNR decreases. NADSET compensates such deterioration in the quality of wind parameter estimates by adaptively utilizing the statistics of Doppler shift estimate in a strong SNR range and identifying sporadic range bins where good Doppler shift estimates are found. The authenticity of NADSET is established by comparing the trend of wind parameters with and without NADSET applied to the long-period lidar return data.

  20. Transcranial Doppler-determined change in posterior cerebral artery blood flow velocity does not reflect vertebral artery blood flow during exercise.

    PubMed

    Washio, Takuro; Sasaki, Hiroyuki; Ogoh, Shigehiko

    2017-04-01

    We examined whether a change in posterior cerebral artery flow velocity (PCAv) reflected the posterior cerebral blood flow in healthy subjects during both static and dynamic exercise. PCAv and vertebral artery (VA) blood flow, as an index of posterior cerebral blood flow, were continuously measured during an exercise trial using transcranial Doppler (TCD) ultrasonography and Doppler ultrasound, respectively. Static handgrip exercise significantly increased both PCAv and VA blood flow. Increasing intensity of dynamic exercise further increased VA blood flow from moderate exercise, while PCAv decreased to almost resting level. During both static and dynamic exercise, the PCA cerebrovascular conductance (CVC) index significantly decreased from rest (static and high-intensity dynamic exercise, -11.5 ± 12.2% and -18.0 ± 16.8%, means ± SD, respectively) despite no change in the CVC of VA. These results indicate that vasoconstriction occurred at PCA but not VA during exercise-induced hypertension. This discrepancy in vascular response to exercise between PCA and VA may be due to different cerebral arterial characteristics. Therefore, to determine the effect of exercise on posterior cerebral circulation, at least, we need to carefully consider which cerebral artery to measure, regardless of exercise mode. NEW & NOTEWORTHY We examined whether transcranial Doppler-determined flow velocity in the posterior cerebral artery can be used as an index of cerebral blood flow during exercise. However, the changes in posterior cerebral artery flow velocity during exercise do not reflect vertebral artery blood flow. Copyright © 2017 the American Physiological Society.

  1. IIP Update: A Packaged Coherent Doppler Wind Lidar Transceiver. Doppler Aerosol WiNd Lidar (DAWN)

    NASA Technical Reports Server (NTRS)

    Kavaya, Michael J.; Koch, Grady J.; Yu, Jirong; Trieu, Bo C.; Amzajerdian, Farzin; Singh, Upendra N.; Petros, Mulugeta

    2006-01-01

    The state-of-the-art 2-micron coherent Doppler wind lidar breadboard at NASA/LaRC will be engineered and compactly packaged consistent with future aircraft flights. The packaged transceiver will be integrated into a coherent Doppler wind lidar system test bed at LaRC. Atmospheric wind measurements will be made to validate the packaged technology. This will greatly advance the coherent part of the hybrid Doppler wind lidar solution to the need for global tropospheric wind measurements.

  2. Spectrophotometric Evaluation of Colour Stability of Nano Hybrid Composite Resin in Commonly Used Food Colourants in Asian Countries.

    PubMed

    Chittem, Jyothi; Sajjan, Girija S; Varma Kanumuri, Madhu

    2017-01-01

    There is growing interest in colour stability of aesthetic restorations. So far few studies have been reported. This study was designed to investigate the effects of different common food colourants i.e., Turmeric and Carmoisine (orange red dye) consumed by patients in Asian countries on a recent nano hybrid composite resin. A total of sixty disk shaped specimens measuring 10 mm in diameter and 2 mm in thickness were prepared. The samples were divided into two groups {Z 100 (Dental restorative composite) Filtek Z 250 XT (Nano hybrid universal restorative)}. Baseline colour measurement of all specimens were made using reflectance spectrophotometer with CIE L*a*b* system. Specimens were immersed in artificial saliva and different experimental solutions containing food colourants (carmoisine solution and turmeric solution) for three hours per day at 37°C. Colour measurements were made after 15 days. Colour difference (ΔE*) was calculated. Mean values were compared by one-way analysis of variance (ANOVA). Multiple range test by Tukey Post-hoc test procedure was employed to identify the significant groups at 5% level. Z 100 showed minimum staining capacity when compared to Z 250 XT in both the colourant solutions. The nanohybrid composite resin containing TEGDMA showed significant colour change when compared to that of microhybrid composite resin as a result of staining in turmeric and carmoisine solution.

  3. Transesophageal Doppler measurement of renal arterial blood flow velocities and indices in children.

    PubMed

    Zabala, Luis; Ullah, Sana; Pierce, Carol D'Ann; Gautam, Nischal K; Schmitz, Michael L; Sachdeva, Ritu; Craychee, Judith A; Harrison, Dale; Killebrew, Pamela; Bornemeier, Renee A; Prodhan, Parthak

    2012-06-01

    Doppler-derived renal blood flow indices have been used to assess renal pathologies. However, transesophageal ultrasonography (TEE) has not been previously used to assess these renal variables in pediatric patients. In this study, we (a) assessed whether TEE allows adequate visualization of the renal parenchyma and renal artery, and (b) evaluated the concordance of TEE Doppler-derived renal blood flow measurements/indices compared with a standard transabdominal renal ultrasound (TAU) in children. This prospective cohort study enrolled 28 healthy children between the ages of 1 and 17 years without known renal dysfunction who were undergoing atrial septal defect device closure in the cardiac catheterization laboratory. TEE was used to obtain Doppler renal artery blood velocities (peak systolic velocity, end-diastolic velocity, mean diastolic velocity, resistive index, and pulsatility index), and these values were compared with measurements obtained by TAU. Concordance correlation coefficient (CCC) was used to determine clinically significant agreement between the 2 methods. The Bland-Altman plots were used to determine whether these 2 methods agree sufficiently to be used interchangeably. Statistical significance was accepted at P ≤ 0.05. Obtaining 2-dimensional images of kidney parenchyma and Doppler-derived measurements using TEE in children is feasible. There was statistically significant agreement between the 2 methods for all measurements. The CCC between the 2 imaging techniques was 0.91 for the pulsatility index and 0.66 for the resistive index. These coefficients were sensitive to outliers. When the highest and lowest data points were removed from the analysis, the CCC between the 2 imaging techniques was 0.62 for the pulsatility index and 0.50 for the resistive index. The 95% confidence interval (CI) for pulsatility index was 0.35 to 0.98 and for resistive index was 0.21 to 0.89. The Bland-Altman plots indicate good agreement between the 2 methods; for the

  4. Colour and Optical Properties of Materials: An Exploration of the Relationship Between Light, the Optical Properties of Materials and Colour

    NASA Astrophysics Data System (ADS)

    Tilley, Richard J. D.

    2003-05-01

    Colour is an important and integral part of everyday life, and an understanding and knowledge of the scientific principles behind colour, with its many applications and uses, is becoming increasingly important to a wide range of academic disciplines, from physical, medical and biological sciences through to the arts. Colour and the Optical Properties of Materials carefully introduces the science behind the subject, along with many modern and cutting-edge applications, chose to appeal to today's students. For science students, it provides a broad introduction to the subject and the many applications of colour. To more applied students, such as engineering and arts students, it provides the essential scientific background to colour and the many applications. Features: * Introduces the science behind the subject whilst closely connecting it to modern applications, such as colour displays, optical amplifiers and colour centre lasers * Richly illustrated with full-colour plates * Includes many worked examples, along with problems and exercises at the end of each chapter and selected answers at the back of the book * A Web site, including additional problems and full solutions to all the problems, which may be accessed at: www.cardiff.ac.uk/uwcc/engin/staff/rdjt/colour Written for students taking an introductory course in colour in a wide range of disciplines such as physics, chemistry, engineering, materials science, computer science, design, photography, architecture and textiles.

  5. Colour blindness in everyday life and car driving.

    PubMed

    Tagarelli, Antonio; Piro, Anna; Tagarelli, Giuseppe; Lantieri, Pasquale Bruno; Risso, Domenico; Olivieri, Rosario Luciano

    2004-08-01

    The aim of the present work was to ascertain, through the administration of a psychosocial questionnaire, the difficulties that subjects with defective colour vision experience in carrying out everyday tasks and work, including driving a car with a driver's licence held for no more than 3 years. Subjects with defective colour vision (n = 151) and subjects with normal vision (n = 302) completed a psychosocial questionnaire regarding the difficulties associated with congenital colour vision deficiency in daily life, work and driving a car. Subjects were diagnosed as colour-blind using the Ishihara test. Statistically significant differences between the two samples were found for daily life activities. Subjects with defective colour vision preferred daytime driving. At night, subjects with defective colour vision had difficulty identifying reflectors on the road and the rear signal lights of cars ahead of them. Colour-blind Calabrian subjects admitted to experiencing colour-related difficulties with a wide range of occupational tasks and leisure pursuits. In particular, colour-blind Calabrian subjects preferred daytime driving, and fewer drove regularly, compared to orthochromatics, who were indifferent to night or daytime driving.

  6. Diagnostic utility of abdominal ultrasonography in dogs with chronic vomiting.

    PubMed

    Leib, M S; Larson, M M; Panciera, D L; Troy, G C; Monroe, W E; Rossmeisl, J H; Forrester, S D; Herring, E S

    2010-01-01

    Chronic vomiting is a common problem in dogs that has many causes. Ultrasonographic descriptions of many gastrointestinal (GI) diseases have been published. However, diagnostic utility of ultrasonography in dogs with chronic vomiting has not been investigated. Diagnostic utility of abdominal ultrasound will be highest in dogs with GI neoplasia and lowest in those with inflammatory disorders. Eighty-nine pet dogs with chronic vomiting. Medical records were reviewed and the contribution of abdominal ultrasound to the clinical diagnosis was subjectively scored. In 68.5% of dogs, the reviewers thought that the same diagnosis would have been reached without performing ultrasonography. In 22.5% of dogs, the ultrasound examination was considered to be vital or beneficial to the diagnosis. Univariable analysis identified that increased diagnostic utility was associated with increasing age, a greater number of vomiting episodes per week, presence of weight loss, a greater percentage of lost body weight, and a final diagnosis of GI lymphoma or gastric adenocarcinoma. However, multivariate analysis only identified increasing age and a final diagnosis of gastric adenocarcinoma or GI lymphoma to be associated with increased diagnostic utility. In 12.4% of dogs, additional benefits of ultrasonography to case management, excluding the contribution to the vomiting problem, were identified. The diagnostic utility of abdominal ultrasonography was high in 27% of dogs. The presence of factors that are associated with high diagnostic utility is an indication to perform abdominal ultrasonography in dogs with chronic vomiting.

  7. Whorfian effects on colour memory are not reliable.

    PubMed

    Wright, Oliver; Davies, Ian R L; Franklin, Anna

    2015-01-01

    The Whorfian hypothesis suggests that differences between languages cause differences in cognitive processes. Support for this idea comes from studies that find that patterns of colour memory errors made by speakers of different languages align with differences in colour lexicons. The current study provides a large-scale investigation of the relationship between colour language and colour memory, adopting a cross-linguistic and developmental approach. Colour memory on a delayed matching-to-sample (XAB) task was investigated in 2 language groups with differing colour lexicons, for 3 developmental stages and 2 regions of colour space. Analyses used a Bayesian technique to provide simultaneous assessment of two competing hypotheses (H1-Whorfian effect present, H0-Whorfian effect absent). Results of the analyses consistently favoured H0. The findings suggest that Whorfian effects on colour memory are not reliable and that the importance of such effects should not be overestimated.

  8. Counting with Colours? Effect of Colours on the Numerical Abilities of House Crows (Corvus splendens) and Common Myna (Acridotheres tristis)

    PubMed Central

    Rahman, Nor Amira Abdul; Ali, Zalila; Zuharah, Wan Fatma; Fadzly, Nik

    2016-01-01

    We conducted several aviary experiments to investigate the influence of colours in quantity judgments of two species of birds; house crow (Corvus splendens) and common myna (Acridotheres tristis). Different quantity (in seven different food proportions) of mealworms were presented nonsequentially to all birds using artificially coloured red mealworms, for experiment 1, and using artificially coloured green mealworms, for experiment 2. Both red and green coloured mealworms have no significant effect on house crow’s quantity judgments (red: ANOVA: F6,30 = 1.748, p = 0.144; and green: ANOVA: F6,30= 1.085, p = 0.394). Common myna, however, showed a strong influence of red colour in their quantity judgment (ANOVA: F6,30 = 2.922, p = 0.023) as they succeeded in choosing the largest amount of food between two cups, but not when offered food using green coloured mealworms (ANOVA: F6,30 = 1.183, p = 0.342). In the next experiment, we hypothesised that both house crow and common myna will prefer red coloured food items over green coloured food items, when factors such as the amount of food is equal. We chose to test red and green colours because both colours play an important role in most avian food selections. Results showed that there were no significant differences in the selection of red or green coloured mealworms for both house crows (ANOVA: F6,30 = 2.310, p = 0.06) and common myna (ANOVA: F6,30 = 0.823, p = 0.561). PMID:27688847

  9. Colour vision requirements in visually demanding occupations.

    PubMed

    Barbur, J L; Rodriguez-Carmona, M

    2017-06-01

    Normal trichromatic colour vision (CV) is often required as a condition for employment in visually demanding occupations. If this requirement could be enforced using current, colour assessment tests, a significant percentage of subjects with anomalous, congenital trichromacy who can perform the suprathreshold, colour-related tasks encountered in many occupations with the same accuracy as normal trichromats would fail. These applicants would therefore be discriminated against unfairly. One solution to this problem is to produce minimum, justifiable CV requirements that are specific to each occupation. This has been done successfully for commercial aviation (i.e. the flight crew) and for Transport for London train drivers. An alternative approach is to make use of new findings and the statistical outcomes of past practices to produce graded, justifiable CV categories that can be enforced. To achieve this aim, we analysed colour assessment outcomes and quantified severity of CV loss in 1363 subjects. The severity of CV loss was measured in each subject and statistical, pass/fail outcomes established for each of the most commonly used, conventional colour assessment tests and protocols. This evidence and new findings that relate severity of loss to the effective use of colour signals in a number of tasks provide the basis for a new colour grading system based on six categories. A single colour assessment test is needed to establish the applicant's CV category which can range from 'supernormal', for the most stringent, colour-demanding tasks, to 'severe colour deficiency', when red/green CV is either absent or extremely weak. © The Author 2017. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  10. Skin colour changes during experimentally-induced sickness.

    PubMed

    Henderson, Audrey J; Lasselin, Julie; Lekander, Mats; Olsson, Mats J; Powis, Simon J; Axelsson, John; Perrett, David I

    2017-02-01

    Skin colour may be an important cue to detect sickness in humans but how skin colour changes with acute sickness is currently unknown. To determine possible colour changes, 22 healthy Caucasian participants were injected twice, once with lipopolysaccharide (LPS, at a dose of 2ng/kg body weight) and once with placebo (saline), in a randomised cross-over design study. Skin colour across 3 arm and 3 face locations was recorded spectrophotometrically over a period of 8h in terms of lightness (L ∗ ), redness (a ∗ ) and yellowness (b ∗ ) in a manner that is consistent with human colour perception. In addition, carotenoid status was assessed as we predicted that a decrease it skin yellowness would reflect a drop in skin carotenoids. We found an early change in skin colouration 1-3h post LPS injection with facial skin becoming lighter and less red whilst arm skin become darker but also less red and less yellow. The LPS injection also caused a drop in plasma carotenoids from 3h onwards. However, the timing of the carotenoid changes was not consistent with the skin colour changes suggesting that other mechanisms, such as a reduction of blood perfusion, oxygenation or composition. This is the first experimental study characterising skin colour associated with acute illness, and shows that changes occur early in the development of the sickness response. Colour changes may serve as a cue to health, prompting actions from others in terms of care-giving or disease avoidance. Specific mechanisms underlying these colour changes require further investigation. Copyright © 2016 Elsevier Inc. All rights reserved.

  11. Field-Portable Pixel Super-Resolution Colour Microscope

    PubMed Central

    Greenbaum, Alon; Akbari, Najva; Feizi, Alborz; Luo, Wei; Ozcan, Aydogan

    2013-01-01

    Based on partially-coherent digital in-line holography, we report a field-portable microscope that can render lensfree colour images over a wide field-of-view of e.g., >20 mm2. This computational holographic microscope weighs less than 145 grams with dimensions smaller than 17×6×5 cm, making it especially suitable for field settings and point-of-care use. In this lensfree imaging design, we merged a colorization algorithm with a source shifting based multi-height pixel super-resolution technique to mitigate ‘rainbow’ like colour artefacts that are typical in holographic imaging. This image processing scheme is based on transforming the colour components of an RGB image into YUV colour space, which separates colour information from brightness component of an image. The resolution of our super-resolution colour microscope was characterized using a USAF test chart to confirm sub-micron spatial resolution, even for reconstructions that employ multi-height phase recovery to handle dense and connected objects. To further demonstrate the performance of this colour microscope Papanicolaou (Pap) smears were also successfully imaged. This field-portable and wide-field computational colour microscope could be useful for tele-medicine applications in resource poor settings. PMID:24086742

  12. Colour vision experimental studies in teaching of optometry

    NASA Astrophysics Data System (ADS)

    Ozolinsh, Maris; Ikaunieks, Gatis; Fomins, Sergejs

    2005-10-01

    Following aspects related to human colour vision are included in experimental lessons for optometry students of University of Latvia. Characteristics of coloured stimuli (emitting and reflective), determination their coordinates in different colour spaces. Objective characteristics of transmitting of colour stimuli through the optical system of eye together with various types of appliances (lenses, prisms, Fresnel prisms). Psychophysical determination of mono- and polychromatic stimuli perception taking into account physiology of eye, retinal colour photoreceptor topography and spectral sensitivity, spatial and temporal characteristics of retinal receptive fields. Ergonomics of visual perception, influence of illumination and glare effects, testing of colour vision deficiencies.

  13. Sexual selection and genetic colour polymorphisms in animals.

    PubMed

    Wellenreuther, Maren; Svensson, Erik I; Hansson, Bengt

    2014-11-01

    Genetic colour polymorphisms are widespread across animals and often subjected to complex selection regimes. Traditionally, colour morphs were used as simple visual markers to measure allele frequency changes in nature, selection, population divergence and speciation. With advances in sequencing technology and analysis methods, several model systems are emerging where the molecular targets of selection are being described. Here, we discuss recent studies on the genetics of sexually selected colour polymorphisms, aiming at (i) reviewing the evidence of sexual selection on colour polymorphisms, (ii) highlighting the genetic architecture, molecular and developmental basis underlying phenotypic colour diversification and (iii) discuss how the maintenance of such polymorphisms might be facilitated or constrained by these. Studies of the genetic architecture of colour polymorphism point towards the importance of tight clustering of colour loci with other trait loci, such as in the case of inversions and supergene structures. Other interesting findings include linkage between colour loci and mate preferences or sex determination, and the role of introgression and regulatory variation in fuelling polymorphisms. We highlight that more studies are needed that explicitly integrate fitness consequences of sexual selection on colour with the underlying molecular targets of colour to gain insights into the evolutionary consequences of sexual selection on polymorphism maintenance. © 2014 John Wiley & Sons Ltd.

  14. IRIS COLOUR CLASSIFICATION SCALES – THEN AND NOW

    PubMed Central

    Grigore, Mariana; Avram, Alina

    2015-01-01

    Eye colour is one of the most obvious phenotypic traits of an individual. Since the first documented classification scale developed in 1843, there have been numerous attempts to classify the iris colour. In the past centuries, iris colour classification scales has had various colour categories and mostly relied on comparison of an individual’s eye with painted glass eyes. Once photography techniques were refined, standard iris photographs replaced painted eyes, but this did not solve the problem of painted/ printed colour variability in time. Early clinical scales were easy to use, but lacked objectivity and were not standardised or statistically tested for reproducibility. The era of automated iris colour classification systems came with the technological development. Spectrophotometry, digital analysis of high-resolution iris images, hyper spectral analysis of the human real iris and the dedicated iris colour analysis software, all accomplished an objective, accurate iris colour classification, but are quite expensive and limited in use to research environment. Iris colour classification systems evolved continuously due to their use in a wide range of studies, especially in the fields of anthropology, epidemiology and genetics. Despite the wide range of the existing scales, up until present there has been no generally accepted iris colour classification scale. PMID:27373112

  15. Colour Reconnection in WW Events

    NASA Astrophysics Data System (ADS)

    D'Hondt, J.

    2003-07-01

    Preliminary results are presented for a measurement of the κ parameter used in the JETSET SK-I model of Colour Reconnection in {W}+{W}^- -> qbar {q}'bar {q}q^' events at LEP2. An update on the investigation of Colour Reconnection effects in hadronic decays of W pairs, using the particle flow in DELPHI is presented. A second method is based on the observation that two different mW estimators have different sensitivity to the parametrised Colour Reconnection effect. Hence the difference between them is an observable with information content about κ.

  16. An economic evaluation of second-trimester genetic ultrasonography for prenatal detection of down syndrome.

    PubMed

    Vintzileos, A M; Ananth, C V; Fisher, A J; Smulian, J C; Day-Salvatore, D; Beazoglou, T; Knuppel, R A

    1998-11-01

    The objective of this study was to perform an economic evaluation of second-trimester genetic ultrasonography for prenatal detection of Down syndrome. More specifically, we sought to determine the following: (1) the diagnostic accuracy requirements (from the cost-benefit point of view) of genetic ultrasonography versus genetic amniocentesis for women at increased risk for fetal Down syndrome and (2) the possible economic impact of second-trimester genetic ultrasonography for the US population on the basis of the ultrasonographic accuracies reported in previously published studies. A cost-benefit equation was developed from the hypothesis that the cost of universal genetic amniocentesis of patients at increased risk for carrying a fetus with Down syndrome should be at least equal to the cost of universal genetic ultrasonography with amniocentesis used only for those with abnormal ultrasonographic results. The main components of the equation included the diagnostic accuracy of genetic ultrasonography (sensitivity and specificity for detecting Down syndrome), the costs of the amniocentesis package and genetic ultrasonography, and the lifetime cost of Down syndrome cases not detected by the genetic ultrasonography. After appropriate manipulation of the equation a graph was constructed, representing the balance between sensitivity and false-positive rate of genetic ultrasonography; this was used to examine the accuracy of previously published studies from the cost-benefit point of view. Sensitivity analyses included individual risks for Down syndrome ranging from 1:261 (risk of a 35-year-old at 18 weeks' gestation) to 1:44 (risk of a 44-year-old at 18 weeks' gestation). This economic evaluation was conducted from the societal perspective. Genetic ultrasonography was found to be economically beneficial only if the overall sensitivity for detecting Down syndrome was >74%. Even then, the cost-benefit ratio depended on the corresponding false-positive rate. Of the 7

  17. Rockpool Gobies Change Colour for Camouflage

    PubMed Central

    Stevens, Martin; Lown, Alice E.; Denton, Alexander M.

    2014-01-01

    Camouflage is found in a wide range of species living in numerous habitat types, offering protection from visually guided predators. This includes many species from the intertidal zone, which must cope with background types diverse in appearance and with multiple predator groups foraging at high and low tide. Many animals are capable of either relatively slow (hours, days, weeks) or rapid (seconds and minutes) colour change in order to better resemble the background against which they are found, but most work has been restricted to a few species or taxa. It is often suggested that many small intertidal fish are capable of colour change for camouflage, yet little experimental work has addressed this. Here, we test rock gobies (Gobius paganellus) for colour change abilities, and whether they can tune their appearance to match the background. In two experiments, we place gobies on backgrounds of different brightness (black or white), and of different colours (red and blue) and use digital image analysis and modelling of predator (avian) vision to quantify colour and luminance (perceived lightness) changes and camouflage. We find that gobies are capable of rapid colour change (occurring within one minute), and that they can change their luminance on lighter or darker backgrounds. When presented on backgrounds of different colours, gobies also change their colour (hue and saturation) while keeping luminance the same. These changes lead to predicted improvements in camouflage match to the background. Our study shows that small rockpool fish are capable of rapid visual change for concealment, and that this may be an important mechanism in many species to avoid predation, especially in complex heterogeneous environments. PMID:25333382

  18. Rockpool gobies change colour for camouflage.

    PubMed

    Stevens, Martin; Lown, Alice E; Denton, Alexander M

    2014-01-01

    Camouflage is found in a wide range of species living in numerous habitat types, offering protection from visually guided predators. This includes many species from the intertidal zone, which must cope with background types diverse in appearance and with multiple predator groups foraging at high and low tide. Many animals are capable of either relatively slow (hours, days, weeks) or rapid (seconds and minutes) colour change in order to better resemble the background against which they are found, but most work has been restricted to a few species or taxa. It is often suggested that many small intertidal fish are capable of colour change for camouflage, yet little experimental work has addressed this. Here, we test rock gobies (Gobius paganellus) for colour change abilities, and whether they can tune their appearance to match the background. In two experiments, we place gobies on backgrounds of different brightness (black or white), and of different colours (red and blue) and use digital image analysis and modelling of predator (avian) vision to quantify colour and luminance (perceived lightness) changes and camouflage. We find that gobies are capable of rapid colour change (occurring within one minute), and that they can change their luminance on lighter or darker backgrounds. When presented on backgrounds of different colours, gobies also change their colour (hue and saturation) while keeping luminance the same. These changes lead to predicted improvements in camouflage match to the background. Our study shows that small rockpool fish are capable of rapid visual change for concealment, and that this may be an important mechanism in many species to avoid predation, especially in complex heterogeneous environments.

  19. The role of colour in implicit and explicit memory performance.

    PubMed

    Vernon, David; Lloyd-Jones, Toby J

    2003-07-01

    We present two experiments that examine the effects of colour transformation between study and test (from black and white to colour and vice versa, of from incorrectly coloured to correctly coloured and vice versa) on implicit and explicit measures of memory for diagnostically coloured natural objects (e.g., yellow banana). For naming and coloured-object decision (i.e., deciding whether an object is correctly coloured), there were shorter response times to correctly coloured-objects than to black-and-white and incorrectly coloured-objects. Repetition priming was equivalent for the different stimulus types. Colour transformation did not influence priming of picture naming, but for coloured-object decision priming was evident only for objects remaining the same from study to test. This was the case for both naming and coloured-object decision as study tasks. When participants were asked to consciously recognize objects that they had named or made coloured-object decisions to previously, whilst ignoring their colour, colour transformation reduced recognition efficiency. We discuss these results in terms of the flexibility of object representations that mediate priming and recognition.

  20. The Colour of Words.

    ERIC Educational Resources Information Center

    Farrar, Bernice Lever

    Students from the ages of 13 or 14 onward need to know the "colours of words" which can let them live fully in the rainbow of life, thus eliminating student fears associated with written language and of being pawns of those who have the power of words, especially written words. Colour coding the eight basic types of work that words can…

  1. Visualising fragrances through colours: the mediating role of emotions.

    PubMed

    Schifferstein, Hendrik N J; Tanudjaja, Inge

    2004-01-01

    To facilitate communication about fragrances, one can use the colours people tend to associate with their smells. We investigated to what extent odour-colour correspondences for fine fragrances can be accounted for by underlying emotional associations. Odour-colour matches and degree-of-fit judgments revealed that odours were matched to colours non-randomly. Matching colours differed mainly on blackness (brightness), and less on chromaticness (saturation) and hue. Furthermore, we found a consistent negative relationship between odour-colour degree-of-fit ratings and the difference between the odour scores and the colour scores on one of the emotion dimensions (pleasure). This suggests that emotional associations may partly underlie odour-colour correspondences.

  2. Mechanisms, functions and ecology of colour vision in the honeybee.

    PubMed

    Hempel de Ibarra, N; Vorobyev, M; Menzel, R

    2014-06-01

    Research in the honeybee has laid the foundations for our understanding of insect colour vision. The trichromatic colour vision of honeybees shares fundamental properties with primate and human colour perception, such as colour constancy, colour opponency, segregation of colour and brightness coding. Laborious efforts to reconstruct the colour vision pathway in the honeybee have provided detailed descriptions of neural connectivity and the properties of photoreceptors and interneurons in the optic lobes of the bee brain. The modelling of colour perception advanced with the establishment of colour discrimination models that were based on experimental data, the Colour-Opponent Coding and Receptor Noise-Limited models, which are important tools for the quantitative assessment of bee colour vision and colour-guided behaviours. Major insights into the visual ecology of bees have been gained combining behavioural experiments and quantitative modelling, and asking how bee vision has influenced the evolution of flower colours and patterns. Recently research has focussed on the discrimination and categorisation of coloured patterns, colourful scenes and various other groupings of coloured stimuli, highlighting the bees' behavioural flexibility. The identification of perceptual mechanisms remains of fundamental importance for the interpretation of their learning strategies and performance in diverse experimental tasks.

  3. Salience of Primary and Secondary Colours in Infancy

    ERIC Educational Resources Information Center

    Franklin, Anna; Pitchford, Nicola; Hart, Lynsey; Davies, Ian R. L.; Clausse, Samantha; Jennings, Siobhan

    2008-01-01

    Primary colour terms ("black", "white", "red", "green", "yellow", and "blue") are more fundamental in colour language than secondary colour terms ("pink", "purple", "orange", "brown", and "grey"). Here, we assess whether this distinction exists in the absence of language, by investigating whether primary colours attract and sustain preverbal…

  4. Imaging of juvenile spondyloarthritis. Part II: Ultrasonography and magnetic resonance imaging

    PubMed Central

    Znajdek, Michał; Gietka, Piotr; Vasilevska-Nikodinovska, Violeta; Patrovic, Lukas; Salapura, Vladka

    2017-01-01

    Juvenile spondyloarthropathies are mainly manifested by symptoms of peripheral arthritis and enthesitis. Early involvement of sacroiliac joints and spine is exceptionally rare in children; this usually happens in adulthood. Conventional radiographs visualize late inflammatory lesions. Early diagnosis is possible with the use of ultrasonography and magnetic resonance imaging. The first part of the article presented classifications and radiographic presentation of juvenile spondyloarthropathies. This part discusses changes seen on ultrasonography and magnetic resonance imaging. In patients with juvenile spondyloarthropathies, these examinations are conducted to diagnose inflammatory lesions in peripheral joints, tendon sheaths, tendons and bursae. Moreover, magnetic resonance also shows subchondral bone marrow edema, which is considered an early sign of inflammation. Ultrasonography and magnetic resonance imaging do not show specific lesions for any rheumatic disease. Nevertheless, they are conducted for early diagnosis, treatment monitoring and identifying complications. This article presents a spectrum of inflammatory changes and discusses the diagnostic value of ultrasonography and magnetic resonance imaging. PMID:29075522

  5. Staggered Multiple-PRF Ultrafast Color Doppler.

    PubMed

    Posada, Daniel; Poree, Jonathan; Pellissier, Arnaud; Chayer, Boris; Tournoux, Francois; Cloutier, Guy; Garcia, Damien

    2016-06-01

    Color Doppler imaging is an established pulsed ultrasound technique to visualize blood flow non-invasively. High-frame-rate (ultrafast) color Doppler, by emissions of plane or circular wavefronts, allows severalfold increase in frame rates. Conventional and ultrafast color Doppler are both limited by the range-velocity dilemma, which may result in velocity folding (aliasing) for large depths and/or large velocities. We investigated multiple pulse-repetition-frequency (PRF) emissions arranged in a series of staggered intervals to remove aliasing in ultrafast color Doppler. Staggered PRF is an emission process where time delays between successive pulse transmissions change in an alternating way. We tested staggered dual- and triple-PRF ultrafast color Doppler, 1) in vitro in a spinning disc and a free jet flow, and 2) in vivo in a human left ventricle. The in vitro results showed that the Nyquist velocity could be extended to up to 6 times the conventional limit. We found coefficients of determination r(2) ≥ 0.98 between the de-aliased and ground-truth velocities. Consistent de-aliased Doppler images were also obtained in the human left heart. Our results demonstrate that staggered multiple-PRF ultrafast color Doppler is efficient for high-velocity high-frame-rate blood flow imaging. This is particularly relevant for new developments in ultrasound imaging relying on accurate velocity measurements.

  6. Links between global and local shape perception, coloured backgrounds, colour discrimination, and non-verbal IQ.

    PubMed

    Dore, Patricia; Dumani, Ardian; Wyatt, Geddes; Shepherd, Alex J

    2018-03-16

    This study explored associations between local and global shape perception on coloured backgrounds, colour discrimination, and non-verbal IQ (NVIQ). Five background colours were chosen for the local and global shape tasks that were tailored for the cone-opponent pathways early in the visual system (cardinal colour directions: L-M, loosely, reddish-greenish; and S-(L + M), or tritan colours, loosely, blueish-yellowish; where L, M and S refer to the long, middle and short wavelength sensitive cones). Participants also completed the Farnsworth-Munsell 100-hue test (FM100) to determine whether performance on the local and global shape tasks correlated with colour discrimination overall, or with performance on the L-M and tritan subsets of the FM100 test. Overall performance on the local and global shape tasks did correlate with scores on the FM100 tests, despite the colour of the background being irrelevant to the shape tasks. There were also significantly larger associations between scores for the L-M subset of the FM100 test, compared to the tritan subset, and accuracy on some of the shape tasks on the reddish, greenish and neutral backgrounds. Participants also completed the non-verbal components of the WAIS and the SPM+ version of Raven's progressive matrices, to determine whether performance on the FM100 test, and on the local and global shape tasks, correlated with NVIQ. FM100 scores correlated significantly with both WAIS and SPM+ scores. These results extend previous work that has indicated FM100 performance is not purely a measure of colour discrimination, but also involves aspects of each participant's NVIQ, such as the ability to attend to local and global aspects of the test, part-whole relationships, perceptual organisation and good visuomotor skills. Overall performance on the local and global shape tasks correlated only with the WAIS scores, not the SPM+. These results indicate that those aspects of NVIQ that engage spatial comprehension of local

  7. Pseudoisochromatic test plate colour representation dependence on printing technology

    NASA Astrophysics Data System (ADS)

    Luse, K.; Fomins, S.; Ozolinsh, M.

    2012-08-01

    The aim of the study is to determine best printing technology for creation of colour vision deficiency tests. Valid tests for protanopia and deuteranopia were created from perceived colour matching experiments from printed colour samples by colour deficient individuals. Calibrated EpsonStylus Pro 7800 printer for ink prints and Noritsu HD 3701 digital printer for photographic prints were used. Multispectral imagery (by tunable liquid crystal filters system CRI Nuance Vis 07) data analysis show that in case of ink prints, the measured pixel colour coordinate dispersion (in the CIExy colour diagram) of similar colour arrays is smaller than in case of photographic printing. The print quality in terms of colour coordinate dispersion for printing methods used is much higher than in case of commercially available colour vision deficiency tests.

  8. The colour of domestication and the designer chicken

    NASA Astrophysics Data System (ADS)

    Sheppy, Andrew

    2011-03-01

    Colour is an important feature of most living organisms. In the wild, colour has great significance affecting the survival and reproductive success of the species. The environmental constraints which lead to the specific colours of birds and animals are very strong and individuals of novel colours tend not to survive. Under domestication, mankind has transformed all the species involved which have thus been freed from environmental pressures to a large extent. Early colour variants were mostly selected for utility reasons or religious practices. In more recent centuries colour varieties have been created purely for ornament and pleasure, fashion playing a surprisingly large part in their development. A bewildering array of colours and patterns can now be found in all our commensal species, especially the Domestic Fowl ( Gallus gallus domesticus).

  9. Looking at anything that is green when hearing "frog": how object surface colour and stored object colour knowledge influence language-mediated overt attention.

    PubMed

    Huettig, Falk; Altmann, Gerry T M

    2011-01-01

    Three eye-tracking experiments investigated the influence of stored colour knowledge, perceived surface colour, and conceptual category of visual objects on language-mediated overt attention. Participants heard spoken target words whose concepts are associated with a diagnostic colour (e.g., "spinach"; spinach is typically green) while their eye movements were monitored to (a) objects associated with a diagnostic colour but presented in black and white (e.g., a black-and-white line drawing of a frog), (b) objects associated with a diagnostic colour but presented in an appropriate but atypical colour (e.g., a colour photograph of a yellow frog), and (c) objects not associated with a diagnostic colour but presented in the diagnostic colour of the target concept (e.g., a green blouse; blouses are not typically green). We observed that colour-mediated shifts in overt attention are primarily due to the perceived surface attributes of the visual objects rather than stored knowledge about the typical colour of the object. In addition our data reveal that conceptual category information is the primary determinant of overt attention if both conceptual category and surface colour competitors are copresent in the visual environment.

  10. Doppler ultrasonographic and scintigraphic assessment of an auxiliary heterotopic liver transplantation with portal vein arterialization in pigs.

    PubMed

    Fernández-Rodríguez, O M; Ríos, A; Navarro, J L; Pons, J A; Palenciano, C G; Mota, R; Berenguer, J J; Mulero, F; Contreras, J; Conesa, C; Ramírez, P; Fuente, T; Parrilla, P

    2006-04-01

    Our aim was to evaluate liver graft integrity and function using scintigraphy and ultrasonography in a porcine model of auxiliary heterotopic liver transplantation with portal vein arterialization (AHLT-PVA). Using Doppler ultrasonography we evaluated eight AHLT-PVA by parenchymal echogenicity, portal and arterial anatomy, and portal and biliary system flow. Two types of scintigraphy were performed: microaggregated human albumin colloid scintigraphy and diisopropyl iminodiacetic acid (DISIDA) scintigraphy, both labeled with 99mTc. The animals were distributed into two groups. The first group consisted of three animals with clinical suspicion of graft dysfunction, in which the ultrasonographic study revealed areas of parenchymal destructuring. In the scintigraphic study, heterogenous uptake was observed; there was no uptake in one animal. Necropsy of these three animals revealed areas of graft necrosis. The second group consisted of five animals with good clinical evolutions, in which the ultrasonographic study showed portal dilation, portal flow with arterial spiculations, and homogenous echogenicity of the hepatic parenchyma. The scintigraphic study revealed homogenous uptake by the graft and an elimination speed of the hepatobiliary agent similar to that of the native liver. An heterogenous echostructure of the graft provided a sign of poor prognosis indicating necrosis in the same way as heterogenous uptake or nonuptake of radioisotope upon scintigraphy. Scintigraphy is a good method to evaluate biliary function and bile elimination. In an AHLT-PVA, the main ultrasound findings derived from arterialization were dilation of the portal system and portal flow with arterial spiculations.

  11. Transcranial Doppler ultrasound study of the effects of nitrous oxide on cerebral autoregulation during neurosurgical anesthesia: a randomized controlled trial.

    PubMed

    Iacopino, Domenico G; Conti, Alfredo; Battaglia, Calogero; Siliotti, Clotilde; Lucanto, Tullio; Santamaria, Letterio B; Tomasello, Francesco

    2003-07-01

    Nitrous oxide has an adverse effect on cerebrovascular hemodynamics. Increased intracranial pressure, cerebral blood flow (CBF), cerebral metabolic rate of O2 (CMRO2), and reduced autoregulation indices have been reported, but their magnitudes are still being debated. This study was designed to evaluate the effect of N2O on CBF and autoregulatory indexes during N2O-sevoflurane anesthesia in a prospective randomized controlled series of patients. Two groups of 20 patients were studied on the basis of the use of N2O in the anesthetic gas mixture. The transient hyperemic response test, which relies on transcranial Doppler ultrasound techniques, was used to assess cerebral hemodynamics. The time-averaged mean flow velocity, considered to be an index of actual CBF, increased significantly (p < 0.001) after introduction of N2O. The hyperemic response, considered as the index of autoregulatory potential, decreased significantly after introduction of N2O into the gas mixture (p < 0.001). The increase in CBF and the reduction in autoregulatory indices suggest caution in using N2O during sevoflurane anesthesia, especially in patients with reduced autoregulatory reserve and during neurosurgical interventions. Transcranial Doppler ultrasonography is an efficacious method to evaluate the effects of anesthetic agents on CBF.

  12. Doppler characteristics of sea clutter.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Raynal, Ann Marie; Doerry, Armin Walter

    2010-06-01

    Doppler radars can distinguish targets from clutter if the target's velocity along the radar line of sight is beyond that of the clutter. Some targets of interest may have a Doppler shift similar to that of clutter. The nature of sea clutter is different in the clutter and exo-clutter regions. This behavior requires special consideration regarding where a radar can expect to find sea-clutter returns in Doppler space and what detection algorithms are most appropriate to help mitigate false alarms and increase probability of detection of a target. This paper studies the existing state-of-the-art in the understanding of Doppler characteristicsmore » of sea clutter and scattering from the ocean to better understand the design and performance choices of a radar in differentiating targets from clutter under prevailing sea conditions.« less

  13. Colour Consideration for Waiting areas in hospitals

    NASA Astrophysics Data System (ADS)

    Zraati, Parisa

    2012-08-01

    Colour is one the most important factors in the nature that can have some affects on human behaviour. Many years ago, it was proven that using colour in public place can have some affect on the users. Depend of the darkness and lightness; it can be vary from positive to negative. The research will mainly focus on the colour and psychological influences and physical factors. The statement of problem in this research is what is impact of colour usually applied to waiting area? The overall aim of the study is to explore the visual environment of hospitals and to manage the colour psychological effect of the hospital users in the waiting area by creating a comfortable, pleasant and cozy environment for users while spend their time in waiting areas. The analysisconcentrate on satisfaction and their interesting regarding applied colour in two private hospital waiting area in Malaysia.

  14. Exploring the benefit of synaesthetic colours: Testing for “pop-out” in individuals with grapheme–colour synaesthesia

    PubMed Central

    Rich, Anina N.; Karstoft, Karen-Inge

    2013-01-01

    In grapheme–colour synaesthesia, letters, numbers, and words elicit involuntary colour experiences. Recently, there has been much emphasis on individual differences and possible subcategories of synaesthetes with different underlying mechanisms. In particular, there are claims that for some, synaesthesia occurs prior to attention and awareness of the inducing stimulus. We first characterized our sample using two versions of the “Synaesthetic Congruency Task” to distinguish “projector” and “associator” synaesthetes who may differ in the extent to which their synaesthesia depends on attention and awareness. We then used a novel modification of the “Embedded Figures Task” that included a set-size manipulation to look for evidence of preattentive “pop-out” from synaesthetic colours, at both a group and an individual level. We replicate an advantage for synaesthetes over nonsynaesthetic controls on the Embedded Figures Task in accuracy, but find no support for pop-out of synaesthetic colours. We conclude that grapheme–colour synaesthetes are fundamentally similar in their visual processing to the general population, with the source of their unusual conscious colour experiences occurring late in the cognitive hierarchy. PMID:23768150

  15. Colour and lighting in hospital design

    NASA Astrophysics Data System (ADS)

    Dalke, Hilary; Little, Jenny; Niemann, Elga; Camgoz, Nilgun; Steadman, Guillaume; Hill, Sarah; Stott, Laura

    2006-06-01

    Little information or guidance has been available to assist the development of a hospital's visual environment. A report on lighting and colour design schemes, accessible to non professionals with responsibility for refurbishment strategies, was required by NHS Estates. Firstly, 20 hospitals were audited to establish a picture of current practice and to identify key issues where colour design could broadly enhance the environment for patients, staff and visitors. Critical areas were outlined in this report, where colour design can be utilised and applied, for the benefit of all users, from ambience to essential legal requirements such as colour contrast for the visually impaired. Provision of staff relaxation rooms that are different in terms of colour and lux levels from immediate work spaces, or thoughtfully designed areas for patients awaiting intensive treatment, have been shown to have some beneficial effects on a sense of well being. Colour and design have not been established as a definite cure for sickness and ill health, but certainly monotony and poor conditions in premises that have not been refurbished with any care, have had a detrimental affect on recovery rates and staff morale. The realisation that a well balanced and attractive environment is of major importance to patients' health is, in no way new; Florence Nightingale observed that 'a variety of form and brilliance of colour in the objects presented to patients are an actual means of recovery'.

  16. Ultrasonography evaluation during the weaning process: the heart, the diaphragm, the pleura and the lung.

    PubMed

    Mayo, P; Volpicelli, G; Lerolle, N; Schreiber, A; Doelken, P; Vieillard-Baron, A

    2016-07-01

    On a regular basis, the intensivist encounters the patient who is difficult to wean from mechanical ventilatory support. The causes for failure to wean from mechanical ventilatory support are often multifactorial and involve a complex interplay between cardiac and pulmonary dysfunction. A potential application of point of care ultrasonography relates to its utility in the process of weaning the patient from mechanical ventilatory support. This article reviews some applications of ultrasonography that may be relevant to the process of weaning from mechanical ventilatory support. The authors have divided these applications of ultrasonography into four separate categories: the assessment of cardiac, diaphragmatic, and lung function; and the identification of pleural effusion; which can all be evaluated with ultrasonography during a dynamic process in which the intensivist is uniquely positioned to use ultrasonography at the point of care. Ultrasonography may have useful application during the weaning process from mechanical ventilatory support.

  17. Eyeballing oscillators for pulsed Doppler radar

    NASA Astrophysics Data System (ADS)

    Goldman, S.

    1985-03-01

    The visibility of small targets to a Doppler radar system in the presence of large targets is limited by phase noise. Such limitations occur when an airborne radar searches the ground for a mobile vehicle. Under these conditions, the performance of the Doppler radar depends greatly on the specifications of its phased-locked oscillator. Goldman (1984) has discussed the steps required to evaluate the noise resulting from a pulsed Doppler radar system. In the present investigation, these techniques are applied in reverse to determine system specifications for oscillator noise. A 95-GHz pulsed Doppler radar system is used as an example of specifying system phase noise.

  18. Shear-wave elastography in breast ultrasonography: the state of the art

    PubMed Central

    2017-01-01

    Shear-wave elastography (SWE) is a recently developed ultrasound technique that can visualize and measure tissue elasticity. In breast ultrasonography, SWE has been shown to be useful for differentiating benign breast lesions from malignant breast lesions, and it has been suggested that SWE enhances the diagnostic performance of ultrasonography, potentially improving the specificity of conventional ultrasonography using the Breast Imaging Reporting and Data System criteria. More recently, not only has SWE been proven useful for the diagnosis of breast cancer, but has also been shown to provide valuable information that can be used as a preoperative predictor of the prognosis or response to chemotherapy. PMID:28513127

  19. Relationship between natural tooth shade and skin colour.

    PubMed

    Nourbakhsh, M; Mousavinejad, N; Adli, A R; Harati, M

    2013-06-01

    The purpose of this study was to assess the correlation of skin colour and tooth shade. One hundred and twenty six individuals aging between 18 to 25 years participated in this study. Colour of the maxillary central incisors was examined by VITA easy shade. Tooth shades were assigned to four ordinal values. Nivea Beauty Protect Foundation shade sample was used as a guide to assess facial skin colour Shin colours were also assigned to four ordinal values. Spearman test revealed that there was a significant relationship between tooth shade and skin colour Total co-relation factor was 51.6% (p <0 .01). Co-relation factors were 57% for women and 27% for men (p <0 .01). The highest tooth shade prevalence belonged to the second group and the highest skin colour prevalence was also in the second skin colour group.

  20. Role of ultrasonography in detecting mammographically occult breast carcinoma in women with dense breasts.

    PubMed

    Corsetti, V; Ferrari, A; Ghirardi, M; Bergonzini, R; Bellarosa, S; Angelini, O; Bani, C; Ciatto, S

    2006-04-01

    The purpose of this study was to assess the usefulness of routine ultrasonography in women with negative mammography and dense breasts [Breast Imaging Reporting and Data System (BIRADS D3-4)]. We applied a protocol involving routine ultrasonography in a consecutive series of subjects with negative mammography and dense breasts. After evaluation by internal and external reviewers of cancers detected by ultrasonography performed to confirm negative mammography, we determined the additional cancer detection rate of ultrasonography and the cost of the protocol. Out of 17,883 total mammographies, 167 cancers were diagnosed (detection rate: 0.93%). Out of 257 suspicious mammographies, 138 cancers were detected. Out of 17,626 negative mammographies, 6,449 (36.5%) were classified as "dense breast" and underwent ultrasonography: 29 cancers were detected (detection rate: 0.44%, or 17.3% of total cancers). Out of 25 cancer cases reviewed, negative mammography and asymptomatic status was confirmed in 15 (detection rate 0.23%, or 8.9% of total cancers). The cancer detection rate was 0.11%, 0.22%, 0.32% and 0.14% for age groups <40, 40-49, 50-59 and >59, respectively. The cost per additional carcinoma detected by ultrasonography alone was euro 25,847.85 whereas that per examined woman was euro 21.68. The study confirms the possibility that ultrasonography can detect mammographically occult breast carcinoma in dense breasts. The evidence is insufficient to recommend this policy in routine screening practice but suggests that, at least in current clinical practice, adding ultrasonography in dense breasts may be useful despite the substantial costs.

  1. Plants and colour: Flowers and pollination

    NASA Astrophysics Data System (ADS)

    Miller, Renee; Owens, Simon J.; Rørslett, Bjørn

    2011-03-01

    While there is a range of colours found in plants the predominant colour is green. Pigments in plants have several roles e.g. photosynthesis and signalling. If colour is to be used as a signal then it must stand out from green. However, one should be aware that there are also coloured compounds where we have not yet fully investigated the role of colour in their functions—they may have roles in, for example, defence or heat exchange. In this paper, we will describe the basic chemistry of the major pigments found in plants and especially floral pigments. We will then discuss their locations in parts of the flower (such as sepals, petals, pollen and nectar), the cells in which they are found and their sub-cellular locations. Floral pigments have a large role to play in pollination of flowers by animals. They can and are modified in many ways during the development of flowers in nature, for example, at emergence and post-pollination. There are a range of biochemical mechanisms of colour change both within flowers and in isolated pigments. Some of the factors influencing colour are temperature, co-pigments, pH, metals, sugars, anthocyanin stacking and cell shape. There is a renewed interest in analysing floral pigments and how they are modified partly because of advances in recombinant DNA technologies, but also because of pollinators and their significance to biodiversity and for evolutionary studies. There is continued strong interest from the horticultural industry for the introduction of new colours e.g. the blue rose and for the exploitation of natural dyes. Funding in this area may impact future research in a potentially beneficial way but it must not deflect us from science-based conservation.

  2. Chromatic VEP in children with congenital colour vision deficiency.

    PubMed

    Tekavčič Pompe, Manca; Stirn Kranjc, Branka; Brecelj, Jelka

    2010-09-01

    Visual evoked potentials to chromatic stimulus (cVEP) are believed to selectively test the parvocellular visual pathway which is responsible for processing information about colour. The aim was to evaluate cVEP in children with red-green congenital colour vision deficiency. VEP responses of 15 colour deficient children were compared to 31 children with normal colour vision. An isoluminant red-green stimulus composed of horizontal gratings was presented in an onset-offset manner. The shape of the waveform was studied, as well as the latency and amplitude of positive (P) and negative (N) waves. cVEP response did not change much with increased age in colour deficient children, whereas normative data showed changes from a predominantly positive to a negative response with increased age. A P wave was present in 87% of colour deficient children (and in 100% of children with normal colour vision), whereas the N wave was absent in a great majority of colour deficient children and was present in 80% of children with normal colour vision. Therefore, the amplitude of the whole response (N-P) decreased linearly with age in colour deficient children, whereas in children with normal colour vision it increased linearly. P wave latency shortened with increased age in both groups. cVEP responses differ in children with congenital colour vision deficiency compared to children with normal colour vision. © 2010 The Authors, Ophthalmic and Physiological Optics © 2010 The College of Optometrists.

  3. Bona fide colour: DNA prediction of human eye and hair colour from ancient and contemporary skeletal remains.

    PubMed

    Draus-Barini, Jolanta; Walsh, Susan; Pośpiech, Ewelina; Kupiec, Tomasz; Głąb, Henryk; Branicki, Wojciech; Kayser, Manfred

    2013-01-14

    DNA analysis of ancient skeletal remains is invaluable in evolutionary biology for exploring the history of species, including humans. Contemporary human bones and teeth, however, are relevant in forensic DNA analyses that deal with the identification of perpetrators, missing persons, disaster victims or family relationships. They may also provide useful information towards unravelling controversies that surround famous historical individuals. Retrieving information about a deceased person's externally visible characteristics can be informative in both types of DNA analyses. Recently, we demonstrated that human eye and hair colour can be reliably predicted from DNA using the HIrisPlex system. Here we test the feasibility of the novel HIrisPlex system at establishing eye and hair colour of deceased individuals from skeletal remains of various post-mortem time ranges and storage conditions. Twenty-one teeth between 1 and approximately 800 years of age and 5 contemporary bones were subjected to DNA extraction using standard organic protocol followed by analysis using the HIrisPlex system. Twenty-three out of 26 bone DNA extracts yielded the full 24 SNP HIrisPlex profile, therefore successfully allowing model-based eye and hair colour prediction. HIrisPlex analysis of a tooth from the Polish general Władysław Sikorski (1881 to 1943) revealed blue eye colour and blond hair colour, which was positively verified from reliable documentation. The partial profiles collected in the remaining three cases (two contemporary samples and a 14th century sample) were sufficient for eye colour prediction. Overall, we demonstrate that the HIrisPlex system is suitable, sufficiently sensitive and robust to successfully predict eye and hair colour from ancient and contemporary skeletal remains. Our findings, therefore, highlight the HIrisPlex system as a promising tool in future routine forensic casework involving skeletal remains, including ancient DNA studies, for the prediction of

  4. Colour Vision: Understanding #TheDress.

    PubMed

    Brainard, David H; Hurlbert, Anya C

    2015-06-29

    A widely-viewed image of a dress elicits striking individual variation in colour perception. Experiments with multiple variants of the image suggest that the individual differences may arise through the action of visual mechanisms that normally stabilise object colour. Copyright © 2015 Elsevier Ltd. All rights reserved.

  5. Simulating Colour Vision Deficiency from a Spectral Image.

    PubMed

    Shrestha, Raju

    2016-01-01

    People with colour vision deficiency (CVD) have difficulty seeing full colour contrast and can miss some of the features in a scene. As a part of universal design, researcher have been working on how to modify and enhance the colour of images in order to make them see the scene with good contrast. For this, it is important to know how the original colour image is seen by different individuals with CVD. This paper proposes a methodology to simulate accurate colour deficient images from a spectral image using cone sensitivity of different cases of deficiency. As the method enables generation of accurate colour deficient image, the methodology is believed to help better understand the limitations of colour vision deficiency and that in turn leads to the design and development of more effective imaging technologies for better and wider accessibility in the context of universal design.

  6. Colour vision deficiency and physics teaching

    NASA Astrophysics Data System (ADS)

    Maule, Louise; Featonby, David

    2016-05-01

    1 in 12 males suffer from some form of colour vision deficiency (CVD) which in the present colour dominated world of education presentation can be a severe disadvantage. Although aware of ‘colourblindness’ most teachers make little or no adjustment for these pupils for whom tasks may be more difficult. This article examines colour vision deficiency and looks at ways in which we can help the many students who have this problem.

  7. An audit of a hospital-based Doppler ultrasound quality control protocol using a commercial string Doppler phantom.

    PubMed

    Cournane, S; Fagan, A J; Browne, J E

    2014-05-01

    Results from a four-year audit of a Doppler quality assurance (QA) program using a commercially available Doppler string phantom are presented. The suitability of the phantom was firstly determined and modifications were made to improve the reliability and quality of the measurements. QA of Doppler ultrasound equipment is very important as data obtained from these systems is used in patient management. It was found that if the braided-silk filament of the Doppler phantom was exchanged with an O-ring rubber filament and the velocity range below 50 cm/s was avoided for Doppler quality control (QC) measurements, then the maximum velocity accuracy (MVA) error and intrinsic spectral broadening (ISB) results obtained using this device had a repeatability of 18 ± 3.3% and 19 ± 3.5%, respectively. A consistent overestimation of the MVA of between 12% and 56% was found for each of the tested ultrasound systems. Of more concern was the variation of the overestimation within each respective transducer category: MVA errors of the linear, curvilinear and phased array probes were in the range 12.3-20.8%, 32.3-53.8% and 27-40.7%, respectively. There is a dearth of QA data for Doppler ultrasound; it would be beneficial if a multicentre longitudinal study was carried out using the same Doppler ultrasound test object to evaluate sensitivity to deterioration in performance measurements. Copyright © 2013 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  8. Biological Components of Colour Preference in Infancy

    ERIC Educational Resources Information Center

    Franklin, Anna; Bevis, Laura; Ling, Yazhu; Hurlbert, Anya

    2010-01-01

    Adult colour preference has been summarized quantitatively in terms of weights on the two fundamental neural processes that underlie early colour encoding: the S-(L+M) ("blue-yellow") and L-M ("red-green") cone-opponent contrast channels ( Ling, Hurlbert & Robinson, 2006; Hurlbert & Ling, 2007). Here, we investigate whether colour preference in…

  9. Acute prostatitis in middle-aged men: a prospective study.

    PubMed

    Kravchick, S; Cytron, S; Agulansky, L; Ben-Dor, D

    2004-01-01

    To determine the clinical outcome of middle-aged men with acute prostatitis, the optimum time for re-assessing their prostate-specific antigen (PSA) levels, and to detect any possible echotextural and vascular changes that remain as a consequence of acute inflammation. Persistent fever prompted a re-evaluation for prostatic abscess formation in 28 middle-aged men, using transrectal ultrasonography (TRUS) colour Doppler imaging, undertaken at the 3-, 6- and 12-month visits. The results of TRUS were compared with laboratory data and clinical outcome. Two abscesses were detected; 19 (68%) of the patients remained infection-free at the 3-month visit. Serum PSA levels were elevated in 11 (39%) of the patients at this visit; three prostate carcinomas were diagnosed. Increased intraprostatic colour flow was detected in 68% and there were hypoechoic areas in 46% of the patients. The re-evaluation for abscess formation should not be postponed for > 48 h. Patients with acute prostatitis tend to have persistent infection. PSA levels could be high even up to 3 months after an acute episode. Middle-aged men with carcinoma could be missed during the acute phase of inflammation. PSA and TRUS monitoring are strongly recommended.

  10. Colour spaces in ecology and evolutionary biology.

    PubMed

    Renoult, Julien P; Kelber, Almut; Schaefer, H Martin

    2017-02-01

    The recognition that animals sense the world in a different way than we do has unlocked important lines of research in ecology and evolutionary biology. In practice, the subjective study of natural stimuli has been permitted by perceptual spaces, which are graphical models of how stimuli are perceived by a given animal. Because colour vision is arguably the best-known sensory modality in most animals, a diversity of colour spaces are now available to visual ecologists, ranging from generalist and basic models allowing rough but robust predictions on colour perception, to species-specific, more complex models giving accurate but context-dependent predictions. Selecting among these models is most often influenced by historical contingencies that have associated models to specific questions and organisms; however, these associations are not always optimal. The aim of this review is to provide visual ecologists with a critical perspective on how models of colour space are built, how well they perform and where their main limitations are with regard to their most frequent uses in ecology and evolutionary biology. We propose a classification of models based on their complexity, defined as whether and how they model the mechanisms of chromatic adaptation and receptor opponency, the nonlinear association between the stimulus and its perception, and whether or not models have been fitted to experimental data. Then, we review the effect of modelling these mechanisms on predictions of colour detection and discrimination, colour conspicuousness, colour diversity and diversification, and for comparing the perception of colour traits between distinct perceivers. While a few rules emerge (e.g. opponent log-linear models should be preferred when analysing very distinct colours), in general model parameters still have poorly known effects. Colour spaces have nonetheless permitted significant advances in ecology and evolutionary biology, and more progress is expected if ecologists

  11. Ultrasonography and magnetic resonance imaging in the diagnosis of Morton's neuroma.

    PubMed

    Fazal, Muhammad Ali; Khan, Ishrat; Thomas, Cherian

    2012-01-01

    Magnetic resonance imaging (MRI) and ultrasonography are used widely for the diagnosis of Morton's neuroma. The aim of this study was to assess the accuracy of these two modalities as diagnostic tools in Morton's neuroma. Fifty feet of 47 consecutive patients (39 women and 8 men; mean age, 46 years; age range, 36-64 years) who presented between January 1, 2005, and June 30, 2008, were included in the study. Twenty-five feet were investigated with ultrasonography and 25 with MRI. Morton's neuroma was confirmed surgically and histologically in all of the patients. A Student unpaired t test was applied. Twenty-two MRIs were diagnostic (sensitivity, 88%). Three patients with negative MRI findings underwent ultrasonography and were found to have a neuroma smaller than 5 mm. Twenty-four ultrasound scans demonstrated the neuroma (sensitivity, 96%), with five neuromas being smaller than 5 mm. Ultrasonography has a slightly higher sensitivity in the diagnosis of Morton's neuroma, particularly of neuromas smaller than 5 mm, and should be the preferred imaging modality in suspected cases, and MRI should be reserved for cases with equivocal diagnosis.

  12. Self-reported skin colour and erythemal sensitivity vs. objectively measured constitutive skin colour in an African population with predominantly dark skin.

    PubMed

    Wright, Caradee Y; Wilkes, Marcus; du Plessis, Johan L; Reeder, Anthony I

    2015-11-01

    Skin colour is an important factor in skin-related diseases. Accurate determination of skin colour is important for disease prevention and supporting healthy sun behaviour, yet such data are lacking for dark skin types. Self-perceived, natural skin colour and sun-skin reaction were compared with objectively measured skin colour among an African population with predominantly dark skin. Unexposed skin of 556 adults (70.1% Black) was measured with a reflectance spectrophotometer to calculate an individual typology angle (°ITA). Participants reported self-perceived skin colour and erythemal sensitivity. There was a strong, positive monotonic correlation between self-reported and measured skin colour (Spearman ρ = 0.6438, P < 0.001), but only a weak correlation between self-reported erythemal sensitivity and measured skin colour (Spearman ρ = 0.2713, P < 0.001). Self-report biases in underestimation and overestimation of skin colour were evident. Many participants with 'dark brown' and 'black' skin had difficulty in classifying erythemal sensitivity. In Africa, self-reported skin colour could potentially be used in lieu of spectrophotometer measurements, but options for questions on sunburn and tanning require suitable adjustment. Our study provides evidence of range in °ITA values among residents in Africa and reinforces previous results that self-report may be reliable for determining skin colour, but not erythemal sensitivity, for dark skin individuals. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  13. Influence of drug colour on perceived drug effects and efficacy.

    PubMed

    Tao, Da; Wang, Tieyan; Wang, Tieshan; Qu, Xingda

    2018-02-01

    A drug's physical characteristics, such as colour, could be factors influencing its therapeutic effects. It is not well understood whether people's expectations on drug effects and efficacy are affected by colour, especially among Chinese population. This study was conducted to examine people's expectations on drug effects and efficacy on the basis of drug colour, and to reveal possible gender differences in colour-related drug expectations. Participants (n = 224) were asked to classify seven single-coloured and six two-coloured capsules into one of four categories of drug effects, and to indicate the strength of drug efficacy. It is found that all the coloured capsules yielded non-chance distributions in classifications of drug effects, with six single-coloured and four two-coloured capsules associated with specific drug effects. Colour also conveyed differential strengths of drug efficacy in general and in relation to specific drug effects. There were gender differences in drug expectations for some colours and colour combinations. Practitioner Summary: Drug colour was found to have impacts on perceived drug effects and efficacy. The findings from the present study can be used by ergonomics practitioners to design appropriate drug colours in support of drug differentiation, therapeutic effects and medication adherence.

  14. Comparison of Radiography and Ultrasonography for Diagnosis of Diaphragmatic Hernia in Bovines

    PubMed Central

    Athar, Hakim; Mohindroo, Jitender; Singh, Kiranjeet; Kumar, Ashwani; Raghunath, Mulinti

    2010-01-01

    The present study was conducted on 101 animals suffering from thoracoabdominal disorders; out of which twenty seven animals (twenty six buffaloes and one cow) were diagnosed with diaphragmatic hernia based on clinical signs, radiography, ultrasonography, and left flank laparorumenotomy. Radiography alone confirmed diaphragmatic hernia in 18 cases (66.67%) with a sac-like structure cranial to the diaphragm. In 15 animals the sac contained metallic densities while in three cases a sac-like structure with no metallic densities was present. Ultrasonography was helpful in confirming diaphragmatic hernia in 23 cases (85.18%) and ultrasonographically reticular motility was evident at the level of 4th/5th intercostal space in all the animals. B+M mode ultrasonography was used for the first time for diagnosis of diaphragmatic hernia in bovines and the results suggested that ultrasonography was a reliable diagnostic modality for diaphragmatic hernia in bovines. PMID:20445795

  15. Performance of physical examination versus ultrasonography to detect stenosis in haemodialysis arteriovenous fistula.

    PubMed

    Maldonado-Cárceles, Ana B; García-Medina, José; Torres-Cantero, Alberto M

    2017-01-18

    The overall purpose of this study is to compare the accuracy of physical examination (PE) versus ultrasonography (US) in people with arteriovenous fistula (AVF). This is a cross-sectional study with a total of 99 patients attended by the vascular radiology unit for AVF evaluation during January - March 2015. PE and ultrasonography were blinded performed by different radiologists. For complete and individual signs of PE, sensitivity, specificity, predictive positive (PPV) and negative (PNV) value, likelihood ratios (LR) and Cohen's κ value were measured. According to ultrasonography, the presence of stenosis was identified in 57 (58%) patients, and 61 (62%) by PE. The accuracy of PE for the diagnosis of AVF was sensitivity 82%, specificity 67%, PPV 77%, NPV 74%, LR 2.74 and 0.26. There was a moderate agreement beyond chance between PE and ultrasonography (κ = 0.5). PE has shown a moderate accuracy to detect stenosis. With non-ultrasonography availability Haemodialysis Units can get benefit to optimize VA survival and professionals should improve its basic skills.

  16. Evaluation of the renal resistive index and pulsatility index in patients with pleural effusion by duplex Doppler ultrasonography.

    PubMed

    Değirmenci, Nevbahar Akcar; Metintaş, Muzaffer; Atlanoglu, Sahinde; Yıldırım, Huseyin

    2013-01-01

    The aim of the study was to evaluate the renal resistive index (RI) and pulsatility index (PI) in patients with pleural effusion (PE). We studied the mean renal RI and PI in 50 patients with PE and 30 healthy volunteers by Doppler sonography. We grouped effusion as unilateral and bilateral. Statistical analysis was done by independent t test and correlation coefficient analysis. The mean RI/PI in healthy volunteers and in PE patients was 0.58/0.93 and 0.72/1.35, respectively. We observed a significantly higher RI and PI in patients when compared with healthy volunteers (all p < 0.001). We found no difference between the renal RI or PI related to unilateral (0.71 or 1.34, respectively) or bilateral effusion (0.74 or 1.55, respectively) (p > 0.05). Pleural effusion might result in increased renal impedance as seen in cirrhosis, which is a rather complicated pathophysiological process, without causing any morphological changes in kidneys.

  17. The evolutionary history of colour polymorphism in Ischnura damselflies.

    PubMed

    Sánchez-Guillén, Rosa A; Cordero-Rivera, Adolfo; Rivas-Torres, Anais; Wellenreuther, Maren; Bybee, Seth; Hansson, Bengt; Velasquez-Vélez, María I; Realpe, Emilio; Chávez-Ríos, Jesús R; Villalobos, Fabricio; Dumont, Henri

    2018-05-10

    A major challenge in evolutionary biology consists of understanding how genetic and phenotypic variation is created and maintained. In the present study, we investigated the origin(s) and evolutionary patterns of the female-limited colour polymorphism in ischnuran damselflies. These consist of the presence of one to three colour morphs: one androchrome morph with a colouration that is similar to the male, and two gynochrome morphs (infuscans and aurantiaca) with female-specific colouration. We (i) documented the colour and mating system of 44 of the 75 taxa within the genus Ischnura, (ii) reconstructed the evolutionary history of colour and mating system to identify the ancestral state, (iii) evaluated the stability of the colour morph status over time, and (iv) tested for a correlation between colour and mating system. We found that the ances tral female colour of Ischnura was monomorphic and aurantiaca and that colour morph status changed over time; characterised by many gains and losses across the species tree. Our results further showed that colour polymorphism is significantly more frequent among polyandric species, whereas monandric species tend to be monomorphic. Research on some Ischnura species has shown that colour morphs have evolved to reduce male mating harassment, and our finding that the same phenotypic morphs have evolved multiple times (convergent evolution) suggests that several species in this genus might be experiencing similar selective pressures. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  18. Colour perception with changes in levels of illumination

    NASA Astrophysics Data System (ADS)

    Baah, Kwame F.; Green, Phil; Pointer, Michael

    2012-01-01

    The perceived colour of a stimulus depends on the conditions under which it is viewed. For colours employed as an important cue or identifier, such as signage and brand colours, colour reproduction tolerances are critically important. Typically, such stimuli would be judged using a known level of illumination but, in the target environment, the level of illumination used to view the samples may be entirely different. The effect of changes in the viewing condition on the perceptibility and acceptability of small colour differences should be understood when such tolerances and associated viewing conditions, are specified. A series of psychophysical experiments was conducted to determine whether changes in illumination level significantly alter acceptability and perceptibility thresholds of uniform colour stimuli. It was found that perceived colour discrimination thresholds varied by up to 2.0 ΔE00. For the perceptual correlate of hue however, this value could be of significance if the accepted error of colour difference was at the threshold, thereby yielding the possibility of rejection with changes in illumination level. Lightness and chroma on the other hand, exhibited greater tolerance and were less likely to be rejected with illuminance changes.

  19. Comparison of the diagnostic value of ultrasonography and standing radiography for pelvic-femoral disorders in horses.

    PubMed

    Geburek, Florian; Rötting, Anna K; Stadler, Peter M

    2009-04-01

    To assess agreement between ultrasonography (transcutaneous and transrectal) and standing radiography in horses with fractures in the pelvic region and disorders of the coxofemoral joint. Case series. Warmblood horses (n=23) and 2 ponies. Medical records (1999-2008) of equids with pelvic or coxofemoral disorders that had pelvic radiography and ultrasonography were retrieved and results of both techniques compared. Radiography and ultrasonography each identified equal numbers of fractures of the tuber coxa (n=4), ilial shaft (2), ischium (3), femoral neck (2), and osteoarthritis/osis of the coxofemoral joint (6). Fractures of the ilial wing (4) were only identified by ultrasonography not by standing radiography. Of 9 acetabular fractures, 3 were identified on radiographs only, 5 were identified with both modalities. One pubic fracture was identified using ultrasonography and radiography. One acetabular and 1 pubic fracture were only diagnosed on necropsy. We found reasonable agreement (73%; 24/33) between ultrasonography and standing radiography for diagnosis of pelvic-femoral disorders. Ultrasonography was more useful for ilial wing fractures and radiography for acetabular fractures. Ultrasonography is a rapid, safe imaging technique for detecting disorders of the pelvic region with a high diagnostic yield and is a preferred initial approach in horses with severe hindlimb lameness.

  20. Development of a forensic skin colour predictive test.

    PubMed

    Maroñas, Olalla; Phillips, Chris; Söchtig, Jens; Gomez-Tato, Antonio; Cruz, Raquel; Alvarez-Dios, José; de Cal, María Casares; Ruiz, Yarimar; Fondevila, Manuel; Carracedo, Ángel; Lareu, María V

    2014-11-01

    There is growing interest in skin colour prediction in the forensic field. However, a lack of consensus approaches for recording skin colour phenotype plus the complicating factors of epistatic effects, environmental influences such as exposure to the sun and unidentified genetic variants, present difficulties for the development of a forensic skin colour predictive test centred on the most strongly associated SNPs. Previous studies have analysed skin colour variation in single unadmixed population groups, including South Asians (Stokowski et al., 2007, Am. J. Hum. Genet, 81: 1119-32) and Europeans (Jacobs et al., 2013, Hum Genet. 132: 147-58). Nevertheless, a major challenge lies in the analysis of skin colour in admixed individuals, where co-ancestry proportions do not necessarily dictate any one person's skin colour. Our study sought to analyse genetic differences between African, European and admixed African-European subjects where direct spectrometric measurements and photographs of skin colour were made in parallel. We identified strong associations to skin colour variation in the subjects studied from a pigmentation SNP discovery panel of 59 markers and developed a forensic online classifier based on naïve Bayes analysis of the SNP profiles made. A skin colour predictive test is described using the ten most strongly associated SNPs in 8 genes linked to skin pigmentation variation. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  1. Behavioural evidence for colour vision in an elasmobranch.

    PubMed

    Van-Eyk, Sarah M; Siebeck, Ulrike E; Champ, Connor M; Marshall, Justin; Hart, Nathan S

    2011-12-15

    Little is known about the sensory abilities of elasmobranchs (sharks, skates and rays) compared with other fishes. Despite their role as apex predators in most marine and some freshwater habitats, interspecific variations in visual function are especially poorly studied. Of particular interest is whether they possess colour vision and, if so, the role(s) that colour may play in elasmobranch visual ecology. The recent discovery of three spectrally distinct cone types in three different species of ray suggests that at least some elasmobranchs have the potential for functional trichromatic colour vision. However, in order to confirm that these species possess colour vision, behavioural experiments are required. Here, we present evidence for the presence of colour vision in the giant shovelnose ray (Glaucostegus typus) through the use of a series of behavioural experiments based on visual discrimination tasks. Our results show that these rays are capable of discriminating coloured reward stimuli from other coloured (unrewarded) distracter stimuli of variable brightness with a success rate significantly different from chance. This study represents the first behavioural evidence for colour vision in any elasmobranch, using a paradigm that incorporates extensive controls for relative stimulus brightness. The ability to discriminate colours may have a strong selective advantage for animals living in an aquatic ecosystem, such as rays, as a means of filtering out surface-wave-induced flicker.

  2. Genetics and evolution of colour patterns in reptiles.

    PubMed

    Olsson, Mats; Stuart-Fox, Devi; Ballen, Cissy

    2013-01-01

    The study of coloration in the polyphyletic reptilians has flourished in the last two decades, in particular with respect to the underlying genetics of colour traits, the function of colours in social interactions, and ongoing selection on these traits in the wild. The taxonomic bias, however, is profound: at this level of resolution almost all available information is for diurnal lizards. Therefore, we focus on case studies, for which there are as complete causal sequences of colour evolution as possible, from phenotypic expression of variation in colour, to ongoing selection in the wild. For work prior to 1992 and for a broader coverage of reptilian coloration we refer the readers to Cooper and Greenburg's (Biology of the Reptilia, 1992) review. There are seven major conclusions we would like to emphasise: (a) visual systems in diurnal lizards are broadly conserved but among the wider range of reptiles in general, there is functionally important variation in the number and type of photoreceptors, spectral tuning of photopigments and optical properties of the eye; (b) coloration in reptiles is a function of complex interactions between structural and pigmentary components, with implications for both proximate control and condition dependence of colour expression; (c) studies of colour-variable species have enabled estimates of heritability of colour and colour patterns, which often show a simple Mendelian pattern of inheritance; (d) colour-polymorphic lizard species sometimes, but not always, show striking differences in genetically encoded reproductive tactics and provide useful models for studying the evolution and maintenance of polymorphism; (e) both male and female colours are sometimes, but not always, a significant component of socio-sexual signalling, often based on multiple traits; (f) evidence for effects of hormones and condition on colour expression, and trade-offs with immunocompetence and parasite load, is variable; (g) lizards show fading of colours

  3. Brain Ultrasonography Findings in Neonatal Seizure; a Cross-sectional Study.

    PubMed

    Nabavi, Seyed Saeed; Partovi, Parinaz

    2017-01-01

    Screening of newborns with seizure, who have curable pathologic brain findings, might be able to improve their final outcome by accelerating treatment intervention. The present study aimed to evaluate the brain ultrasonography findings of newborns hospitalized with complaint of seizure. The present cross-sectional study designed to evaluate brain ultrasonography findings of hospitalized newborns complaining seizure. Neonatal seizure was defined as presence of tonic, clonic, myoclonic, and subtle attacks in 1 - 28 day old newborns. 100 newborns with the mean age of 5.82 ± 6.29 days were evaluated (58% male). Most newborns were in the < 10 days age range (76%), term (83%) and with normal birth weight (81%). 22 (22%) of the ultrasonography examinations showed a pathologic finding. A correlation was only found between birth age and probability of the presence of a pathologic problem in the brain as the frequency of these problems was significantly higher in pre-term newborns (p = 0.023). Based on the findings of the present study, frequency of pathologic findings in neonatal brain ultrasonography was 22%. Hemorrhage (12%) and hydrocephaly (7%) were the most common findings. The only factor correlating with increased probability of positive findings was the newborns being pre-term.

  4. The medical Doppler in hand surgery: its scientific basis, applications, and the history of its namesake, Christian Johann Doppler.

    PubMed

    Ghori, Ahmer K; Chung, Kevin C

    2007-12-01

    The word Doppler is used synonymously in hand surgery for evaluating patency of vascular structures; however, the science and history behind the Doppler effect are not as well-known. We will present the theories behind the Doppler effect and the history of the person who made this discovery.

  5. Noncoherent Doppler tracking: first flight results

    NASA Astrophysics Data System (ADS)

    DeBoy, Christopher C.; Robert Jensen, J.; Asher, Mark S.

    2005-01-01

    Noncoherent Doppler tracking has been devised as a means to achieve highly accurate, two-way Doppler measurements with a simple, transceiver-based communications system. This technique has been flown as an experiment on the Thermosphere, Ionosphere, Mesosphere, Energetics and Dynamics (TIMED) spacecraft, (launched 7 December 2001), as the operational technique for Doppler tracking on CONTOUR, and is baselined on several future deep space missions at JHU/APL. This paper reports on initial results from a series of successful tests of this technique between the TIMED spacecraft and NASA ground stations in the Deep Space Network. It also examines the advantages that noncoherent Doppler tracking and a transceiver-based system may offer to small satellite systems, including reduced cost, mass, and power.

  6. Complementary Colours for a Physicist

    ERIC Educational Resources Information Center

    Babic, Vitomir; Cepic, Mojca

    2009-01-01

    This paper reports on a simple experiment which enables splitting incident light into two different modes, each having a colour exactly complementary to the other. A brief historical development of colour theories and differences in a physicist's point of view with respect to an artist's one is discussed. An experimental system for producing…

  7. Geographical variation in colour of female threespine stickleback (Gasterosteus aculeatus)

    PubMed Central

    Ingram, Travis; Bolnick, Daniel I.

    2018-01-01

    The ecological multifunctionality of colour often results in multiple selective pressures operating on a single trait. Most research on colour evolution focuses on males because they are the most conspicuous sex in most species. This bias can limit inferences about the ecological drivers of colour evolution. For example, little is known about population divergence in colour of female threespine stickleback (Gasterosteus aculeatus), which is among the most intensively-studied model vertebrates in evolution, ecology, and behaviour. In contrast, the evolution and ecology of colour in male stickleback has received considerable attention. One aspect of female colouration that is lacking previous research is non-ornamental body colour. Non-ornamental colour can play defensive and social roles, and indicate other aspects of female stickleback ecology. To remedy this knowledge gap, we measured the colour and brightness of one dorsal and one ventral lateral area on female stickleback from nine lake populations on Vancouver Island. We found that lake populations varied in overall colour brightness and dorso-ventral contrast. In addition, we found that female brightness increased with lake size, indicating potential ecological drivers of these colour differences. Our results demonstrate that there is substantial scope for future research on female colour diversification, which has been overlooked because past researchers focused on dramatic male nuptial colours. PMID:29785354

  8. Geographical variation in colour of female threespine stickleback (Gasterosteus aculeatus).

    PubMed

    French, Connor M; Ingram, Travis; Bolnick, Daniel I

    2018-01-01

    The ecological multifunctionality of colour often results in multiple selective pressures operating on a single trait. Most research on colour evolution focuses on males because they are the most conspicuous sex in most species. This bias can limit inferences about the ecological drivers of colour evolution. For example, little is known about population divergence in colour of female threespine stickleback ( Gasterosteus aculeatus ), which is among the most intensively-studied model vertebrates in evolution, ecology, and behaviour. In contrast, the evolution and ecology of colour in male stickleback has received considerable attention. One aspect of female colouration that is lacking previous research is non-ornamental body colour. Non-ornamental colour can play defensive and social roles, and indicate other aspects of female stickleback ecology. To remedy this knowledge gap, we measured the colour and brightness of one dorsal and one ventral lateral area on female stickleback from nine lake populations on Vancouver Island. We found that lake populations varied in overall colour brightness and dorso-ventral contrast. In addition, we found that female brightness increased with lake size, indicating potential ecological drivers of these colour differences. Our results demonstrate that there is substantial scope for future research on female colour diversification, which has been overlooked because past researchers focused on dramatic male nuptial colours.

  9. Laser Doppler flowmetry, transcutaneous oxygen tension measurements and Doppler pressure compared in patients undergoing amputation.

    PubMed

    Lantsberg, L; Goldman, M

    1991-04-01

    The level of amputation continues to present a challenge for surgeons. In view of this, 24 patients who required an amputation of their ischaemic leg were studied prospectively using Laser Doppler flowmetry (LDF), TcpO2 measurements and Doppler ultrasound to assess the best level for amputation. In all patients gangrene of the leg and rest pain were the indication for an amputation. Skin oxygen tension (TcpO2) and skin blood flow (LDF) measurements were obtained the day before surgery on the proposed anterior and posterior skin flaps for below knee amputation and the maximum Doppler systolic pressure was measured. The level of amputation was chosen at surgery by clinical judgement without reference to the measurements mentioned above. A below knee amputation was performed in 17 patients and an above knee in seven. All amputations healed by primary intention. Doppler pressures showed poor discrimination with a median value of 10 mmHg (0-25) in AK patients and 35 mmHg (0-85) in the BK group (p greater than 0.05). In contrast TcpO2 showed a trend. In the BK group the median value was 20 mmHg (4-50) on the anterior and 22 mmHg (2-60) on the posterior flap compared to above knee amputees with median values of 6 mmHg (2-11) and 8 mmHg (3-38), respectively (p greater than 0.05). Laser Doppler seemed more useful. In BK patients the median LDF values were 36 mV (20-85) on the anterior and 34 mV (20-80) on the posterior flap with median LDF values of 10 mV (10-18) on the anterior and 11 mV (8-38) on the posterior flap in the above knee group (p less than 0.01). Laser Doppler flowmetry is a simple objective test, which is a better discriminator of skin flap perfusion than either TcpO2 or Doppler ankle pressures.

  10. Ultrasound resistive index, power Doppler, and clinical parameters in established rheumatoid arthritis.

    PubMed

    Bisi, Melissa Cláudia; do Prado, Aline Defaveri; Piovesan, Deise Marcela; Bredemeier, Markus; da Silveira, Inês Guimarães; Mendonça, José Alexandre; Staub, Henrique Luiz

    2017-04-01

    Ultrasonography (US) is a useful tool for the evaluation of sinovial vascularization and proliferation in rheumatoid arthritis (RA). Accordingly, resistive index (RI) on spectral Doppler (sD) US provides a quantitative analysis of vascular inflammation, but its utility in the evaluation of RA activity has not been established. Our objective was to determine the association of RI with other US parameters of synovitis and with clinical disease activity in established RA. Patients with positive power Doppler (pD) were included in a prospective cross-sectional study. Disease activity and disability were evaluated using the Disease Activity Score in 28-joints (DAS28) and Health Assessment Questionnaire (HAQ), respectively. Gray scale (GS) synovitis, pD, and sD analyses were performed by one of two examiners in wrists and the second and third metacarpophalangeal and proximal interphalangeal joints. The 10-joint GS and 10-joint pD scores and mean RI were then calculated. Weighted kappa (WK) values were employed to assess interobserver reability, and correlations were tested using the Spearman coefficient. Ninety-five RA patients (median duration of disease of 7 years and mean DAS28 of 4.32 ± 1.66) were included. WK values in real-time US were 0.77 for synovitis, 0.87 for pD, and 0.68 for RI. There were no significant correlations of RI with 10-joint GS, 10-joint pD, DAS28, joint counts, or HAQ (P > 0.10 for all tests). Patients in remission had a mean RI similar to those with high disease activity (0.62 ± 0.10, n = 15 versus 0.63 ± 0.13, n = 34, respectively). The addition of the RI score did not seem to improve US performance in patients with established RA.

  11. How big does a coloured overlay have to be?

    PubMed

    Waldie, Michelle; Wilkins, Arnold

    2004-01-01

    Coloured overlays and coloured lenses can both increase reading speed, but when they do their colour is not necessarily the same, suggesting that the beneficial effects of a coloured filter might depend upon the area of the visual field that it colours. We investigated the effects of overlays on reading speed and varied the size of the overlay and the colour of the surround. Children who had been assessed with coloured overlays were required to read a passage of randomly ordered common words. The words were printed in black ink as a block of text positioned centrally on an A4 page of white paper in landscape orientation. The speed of reading was compared under four conditions: (1) without an overlay; (2) with an overlay of the chosen colour covering the entire page; (3) with the overlay cut so that it just covered the text but left the margin white; (4) with the overlay of the chosen colour covering the text but with the margin coloured a complementary colour, using a second overlay. The children who were using an overlay read more quickly with the overlay; those who were no longer using the overlay did not. Although the block of text covered less than half the page, the colour and nature of the margin did not affect reading speed significantly. These findings suggest that in order to be effective at improving reading speed an overlay needs to cover the text, but not necessarily the remainder of the page, which means that smaller overlays may sometimes be sufficient.

  12. Isolated Deep Venous Thrombosis: Implications for 2-Point Compression Ultrasonography of the Lower Extremity.

    PubMed

    Adhikari, Srikar; Zeger, Wes; Thom, Christopher; Fields, J Matthew

    2015-09-01

    Two-point compression ultrasonography focuses on the evaluation of common femoral and popliteal veins for complete compressibility. The presence of isolated thrombi in proximal veins other than the common femoral and popliteal veins should prompt modification of 2-point compression technique. The objective of this study is to determine the prevalence and distribution of deep venous thrombi isolated to lower-extremity veins other than the common femoral and popliteal veins in emergency department (ED) patients with clinically suspected deep venous thrombosis. This was a retrospective study of all adult ED patients who received a lower-extremity venous duplex ultrasonographic examination for evaluation of deep venous thrombosis during a 6-year period. The ultrasonographic protocol included B-mode, color-flow, and spectral Doppler scanning of the common femoral, femoral, deep femoral, popliteal, and calf veins. Deep venous thrombosis was detected in 362 of 2,451 patients (14.7%; 95% confidence interval [CI] 13.3% to 16.1%). Thrombus confined to the common femoral vein alone was found in 5 of 362 cases (1.4%; 95% CI 0.2% to 2.6%). Isolated femoral vein thrombus was identified in 20 of 362 patients (5.5%; 95% CI 3.2% to 7.9%). Isolated deep femoral vein thrombus was found in 3 of 362 cases (0.8%; 95% CI -0.1% to 1.8%). Thrombus in the popliteal vein alone was identified in 53 of 362 cases (14.6%; 95% CI 11% to 18.2%). In our study, 6.3% of ED patients with suspected deep venous thrombosis had isolated thrombi in proximal veins other than common femoral and popliteal veins. Our study results support the addition of femoral and deep femoral vein evaluation to standard compression ultrasonography of the common femoral and popliteal vein, assuming that this does not have a deleterious effect on specificity. Copyright © 2014 American College of Emergency Physicians. Published by Elsevier Inc. All rights reserved.

  13. Ultrasonography of hydronephrosis in the newborn: a practical review

    PubMed Central

    2016-01-01

    Widespread use of fetal ultrasonography is accompanied by more frequent detection of antenatal hydronephrosis. Therefore, sonographic evaluation of neonates with a history of antenatal hydronephrosis is becoming more widespread. As an initial postnatal non-invasive imaging modality, ultrasonography is used to screen for persistence of hydronephrosis, determine the level and severity of obstruction, and contribute to appropriate diagnosis and treatment. This review aims to provide a practical overview of the sonographic evaluation of neonatal hydronephrosis and to describe the sonographic findings of conditions associated with hydronephrosis in the newborn. PMID:27156562

  14. Digital Doppler measurement with spacecraft

    NASA Technical Reports Server (NTRS)

    Kinman, Peter W.; Hinedi, Sami M.; Labelle, Remi C.; Bevan, Roland P.; Del Castillo, Hector M.; Chong, Dwayne C.

    1991-01-01

    Digital and analog phase-locked loop (PLL) receivers were operated in parallel, each tracking the residual carrier from a spacecraft. The PLL tracked the downlink carrier and measured its instantaneous phase. This information, combined with a knowledge of the uplink carrier and the transponder ratio, permitted the computation of a Doppler observable. In this way, two separate Doppler measurements were obtained for one observation window. The two receivers agreed on the magnitude of the Doppler effect to within 1 mHz. There was less jitter on the data from the digital receiver. This was due to its smaller noise bandwidth. The demonstration and its results are described.

  15. Limits of colour vision in dim light.

    PubMed

    Kelber, Almut; Lind, Olle

    2010-09-01

    Humans and most vertebrates have duplex retinae with multiple cone types for colour vision in bright light, and one single rod type for achromatic vision in dim light. Instead of comparing signals from multiple spectral types of photoreceptors, such species use one highly sensitive receptor type thus improving the signal-to-noise ratio at night. However, the nocturnal hawkmoth Deilephila elpenor, the nocturnal bee Xylocopa tranquebarica and the nocturnal gecko Tarentola chazaliae can discriminate colours at extremely dim light intensities. To be able to do so, they sacrifice spatial and temporal resolution in favour of colour vision. We review what is known about colour vision in dim light, and compare colour vision thresholds with the optical sensitivity of the photoreceptors in selected animal species with lens and compound eyes. © 2010 The Authors, Ophthalmic and Physiological Optics © 2010 The College of Optometrists.

  16. Music-colour synaesthesia: Concept, context and qualia.

    PubMed

    Curwen, Caroline

    2018-05-01

    This review provides a commentary on coloured-hearing arising on hearing music: music-colour synaesthesia. Although traditionally explained by the hyperconnectivity theory (Ramachandran & Hubbard, 2001a) and the disinhibited feedback theory (Grossenbacher & Lovelace, 2001) as a purely perceptual phenomenon, the review of eight coloured-hearing neuroimaging studies shows that it may not be assumed that these explanations are directly translatable to music-colour synaesthesia. The concept of 'ideaesthesia' (Nikolić, 2009) and the role of conceptual and semantic inducers challenge the likelihood of a single mechanism underlying the cause of synaesthesia and argue for a move away from a purely sensory to sensory explanation. Finally, music-colour synaesthesia forms a challenge for established philosophical theories and the position of synaesthesia is considered within the larger context of musical qualia. Copyright © 2018 Elsevier Inc. All rights reserved.

  17. A familial factor in the development of colour agnosia.

    PubMed

    Nijboer, Tanja C W; van Zandvoort, Martine J E; de Haan, Edward H F

    2007-04-09

    An important aspect of research into the link between genes and behaviour concerns the identification of familial determination. There is evidence for familial factors in selective deficits, such as developmental dyslexia and developmental prosopagnosia. Colour agnosia concerns a selective neuropsychological condition in which colour perception is intact, while the identification and naming of colour is disrupted. We recently demonstrated that this deficit can occur as a developmental deficit. Here, we show that there is a familial factor in the development of colour agnosia by reporting the colour processing abilities of the mother and the daughters of a man with developmental colour agnosia.

  18. Children's colour choices for completing drawings of affectively characterised topics.

    PubMed

    Burkitt, Esther; Barrett, Martyn; Davis, Alyson

    2003-03-01

    This study was designed to explore whether or not children systematically use particular colours when completing drawings of affectively characterised topics. Three hundred and thirty 4-11-year-old children were subdivided into three conditions, colouring in a drawing of a man, a dog, or a tree, respectively. The children completed two test sessions in counterbalanced order. In one session, children rated and ranked ten colours in order of preference. In the other session, children completed three colouring tasks in which they had to colour in three identical figures but which had been given different affective characterisations: a neutrally characterised figure, a figure characterised as nasty, and a figure characterised as nice. It was found that, in all age groups and for all topics, the children used their more preferred colours for the nice figures, their least preferred colours for the nasty figures, and colours rated intermediately for the neutral figures. It was also found that, in all age groups and for all topics, black tended to be the most frequently chosen colour for colouring in the drawings of the negatively characterised figures. By contrast, primary colours were predominantly selected for the neutral figure, while a wide range of mainly primary and secondary colours were chosen for colouring in the nice figure. These results suggest that children are able to alter systematically their use of colour during picture completion tasks in response to differential affective topic characterisations, and that even very young children are able to use colours symbolically.

  19. Physicochemical and physiological basis of dichromatic colour

    NASA Astrophysics Data System (ADS)

    Kreft, Samo; Kreft, Marko

    2007-11-01

    Out of three perceptual characteristics of the colour of any substance, the hue depends mostly on the spectral properties of a substance, while the brightness and saturation depend also on the concentration of a substance and its thickness. Here, we report that evident change of the hue of the colour (i.e., from green to red) is due to a change in concentration or the thickness of a layer in some exceptional substances such as pumpkin seed oil or an aqueous solution of bromophenol blue. In some regions of Central Europe, salad dressing is made preferably with the pumpkin seed oil, which has a strong characteristic nut-like taste and remarkable properties of the colour: it appears red in a bottle, but green when served as a salad dressing. The colour of the pumpkin seed oil was previously described as brownish yellow, dark green, dark green to red ochre or dark reddish brown to light yellow green. We elucidated the physicochemical and physiological basis of such dichromatism by Beer-Lambert law and by the characteristics of human colour perception. Our concept was corroborated by the outcome of calculations of colour from spectral properties using colour matching functions. We found that dichromatism is observed if the absorption spectrum of any substance has at least two local minima: one wide but shallow and one narrow but deep local minimum.

  20. Spatio-temporal colour correction of strongly degraded movies

    NASA Astrophysics Data System (ADS)

    Islam, A. B. M. Tariqul; Farup, Ivar

    2011-01-01

    The archives of motion pictures represent an important part of precious cultural heritage. Unfortunately, these cinematography collections are vulnerable to different distortions such as colour fading which is beyond the capability of photochemical restoration process. Spatial colour algorithms-Retinex and ACE provide helpful tool in restoring strongly degraded colour films but, there are some challenges associated with these algorithms. We present an automatic colour correction technique for digital colour restoration of strongly degraded movie material. The method is based upon the existing STRESS algorithm. In order to cope with the problem of highly correlated colour channels, we implemented a preprocessing step in which saturation enhancement is performed in a PCA space. Spatial colour algorithms tend to emphasize all details in the images, including dust and scratches. Surprisingly, we found that the presence of these defects does not affect the behaviour of the colour correction algorithm. Although the STRESS algorithm is already in itself more efficient than traditional spatial colour algorithms, it is still computationally expensive. To speed it up further, we went beyond the spatial domain of the frames and extended the algorithm to the temporal domain. This way, we were able to achieve an 80 percent reduction of the computational time compared to processing every single frame individually. We performed two user experiments and found that the visual quality of the resulting frames was significantly better than with existing methods. Thus, our method outperforms the existing ones in terms of both visual quality and computational efficiency.

  1. Colour contribution to children's wayfinding in school environments

    NASA Astrophysics Data System (ADS)

    Helvacıoǧlu, Elif; Olguntürk, Nilgün

    2011-03-01

    The purpose of this study was to explore the contribution of colour to children's wayfinding ability in school environments and to examine the differences between colours in terms of their remembrance and usability in route learning process. The experiment was conducted with three different sample groups for each of three experiment sets differentiated by their colour arrangement. The participants totalled 100 primary school children aged seven and eight years old. The study was conducted in four phases. In the first phase, the participants were tested for familiarity with the experiment site and also for colour vision deficiencies by using Ishihara's tests for colour-blindness. In the second phase, they were escorted on the experiment route by the tester one by one, from one starting point to one end point and were asked to lead the tester to the end point by the same route. In the third phase, they were asked to describe verbally the route. In the final phase, they were asked to remember the specific colours at their correct locations. It was found that colour has a significant effect on children's wayfinding performances in school environments. However, there were no differences between different colours in terms of their remembrances in route finding tasks. In addition, the correct identifications of specific colours and landmarks were dependent on their specific locations. Contrary to the literature, gender differences were not found to be significant in the accuracy of route learning performances.

  2. Bona fide colour: DNA prediction of human eye and hair colour from ancient and contemporary skeletal remains

    PubMed Central

    2013-01-01

    Background DNA analysis of ancient skeletal remains is invaluable in evolutionary biology for exploring the history of species, including humans. Contemporary human bones and teeth, however, are relevant in forensic DNA analyses that deal with the identification of perpetrators, missing persons, disaster victims or family relationships. They may also provide useful information towards unravelling controversies that surround famous historical individuals. Retrieving information about a deceased person’s externally visible characteristics can be informative in both types of DNA analyses. Recently, we demonstrated that human eye and hair colour can be reliably predicted from DNA using the HIrisPlex system. Here we test the feasibility of the novel HIrisPlex system at establishing eye and hair colour of deceased individuals from skeletal remains of various post-mortem time ranges and storage conditions. Methods Twenty-one teeth between 1 and approximately 800 years of age and 5 contemporary bones were subjected to DNA extraction using standard organic protocol followed by analysis using the HIrisPlex system. Results Twenty-three out of 26 bone DNA extracts yielded the full 24 SNP HIrisPlex profile, therefore successfully allowing model-based eye and hair colour prediction. HIrisPlex analysis of a tooth from the Polish general Władysław Sikorski (1881 to 1943) revealed blue eye colour and blond hair colour, which was positively verified from reliable documentation. The partial profiles collected in the remaining three cases (two contemporary samples and a 14th century sample) were sufficient for eye colour prediction. Conclusions Overall, we demonstrate that the HIrisPlex system is suitable, sufficiently sensitive and robust to successfully predict eye and hair colour from ancient and contemporary skeletal remains. Our findings, therefore, highlight the HIrisPlex system as a promising tool in future routine forensic casework involving skeletal remains, including

  3. Floral colour versus phylogeny in structuring subalpine flowering communities.

    PubMed

    McEwen, Jamie R; Vamosi, Jana C

    2010-10-07

    The relative number of seeds produced by competing species can influence the community structure; yet, traits that influence seed production, such as pollinator attraction and floral colour, have received little attention in community ecology. Here, we analyse floral colour using reflectance spectra that include near-UV and examined the phylogenetic signal of floral colour. We found that coflowering species within communities tended to be more divergent in floral colour than expected by chance. However, coflowering species were not phylogenetically dispersed, in part due to our finding that floral colour is a labile trait with a weak phylogenetic signal. Furthermore, while we found that locally rare and common species exhibited equivalent floral colour distances from their coflowering neighbours, frequent species (those found in more communities) exhibited higher colour distances from their coflowering neighbours. Our findings support recent studies, which have found that (i) plant lineages exhibit frequent floral colour transitions; and (ii) traits that influence local population dynamics contribute to community structure.

  4. Evaluation of cerebral blood flow changes in focal cerebral ischemia rats by using transcranial Doppler ultrasonography.

    PubMed

    Li, Le; Ke, Zheng; Tong, Kai Yu; Ying, Michael

    2010-04-01

    Ischemic stroke is typically characterized by the disruption of cerebral blood flow. This study aimed to consecutively evaluate the cerebral blood flow changes in a focal ischemia rat model during the occlusion-reperfusion procedure and along the recovery stage after stroke. In 12 Sprague Dawley (SD) rats, a middle cerebral artery occlusion/reperfusion (MCAo/r) surgery was conducted, which combines a permanent occlusion of the right common carotid artery (CCA), external carotid artery (ECA) and a transient occlusion of the right internal carotid artery (ICA) and middle cerebral artery (MCA) with a monofilament introduced from the proximal ICA towards the distal right ICA then removed after 90 min. Blood flow velocity (BFV) from the concerned arteries were measured using ultrasonography (13-4 MHz) at the basal stage before the surgery, after the reperfusion stage and during the post-stroke status. At reperfusion stage and after, BFV increased significantly in the left ICA and in the basilar artery (BA) (starting from post-24 h, p < 0.05 vs. basal). Moreover, BFV were reversed in the distal right ICA and reflow was recorded in the right MCA. Time-average maximum BFV in the right MCA at reperfusion and post-stroke 24-96 h was decreased significantly (p < 0.05 vs. basal). The reversed flow in the right ICA was enabled by the settlement of the collateral supply through the circle of Willis which consisted in higher BFV in the opposite ICA and in the BA still 24 h, although the proximal right ICA remain occluded. Ultrasound measurement of BFV helps to provide information on the redistribution of the blood flow supply after the onset of stroke. Copyright 2010 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  5. Near-infrared Fluorescence Optical Imaging in Early Rheumatoid Arthritis: A Comparison to Magnetic Resonance Imaging and Ultrasonography.

    PubMed

    Krohn, Michaela; Ohrndorf, Sarah; Werner, Stephanie G; Schicke, Bernd; Burmester, Gerd-Rüdiger; Hamm, Bernd; Backhaus, Marina; Hermann, Kay-Geert A

    2015-07-01

    Near-infrared fluorescence optical imaging (FOI) is a novel imaging technology in the detection and evaluation of different arthritides. FOI was validated in comparison to magnetic resonance imaging (MRI), greyscale ultrasonography (GSUS), and power Doppler ultrasonography (PDUS) in patients with early rheumatoid arthritis (RA). Hands of 31 patients with early RA were examined by FOI, MRI, and US. In each modality, synovitis of the wrist, metacarpophalangeal joints (MCP) 2-5, and proximal interphalangeal joints (PIP) 2-5 were scored on a 4-point scale (0-3). Sensitivity and specificity of FOI were analyzed in comparison to MRI and US as reference methods, differentiating between 3 phases of FOI enhancement (P1-3). Intraclass correlation coefficients (ICC) were calculated to evaluate the agreement of FOI with MRI and US. A total of 279 joints (31 wrists, 124 MCP and 124 PIP joints) were evaluated. With MRI as the reference method, overall sensitivity/specificity of FOI was 0.81/0.00, 0.49/0.84, and 0.86/0.38 for wrist, MCP, and PIP joints, respectively. Under application of PDUS as reference, sensitivity was even higher, while specificity turned out to be low, except for MCP joints (0.88/0.15, 0.81/0.76, and 1.00/0.27, respectively). P2 appears to be the most sensitive FOI phase, while P1 showed the highest specificity. The best agreement of FOI was shown for PDUS, especially with regard to MCP and PIP joints (ICC of 0.57 and 0.53, respectively), while correlation with MRI was slightly lower. FOI remains an interesting diagnostic tool for patients with early RA, although this study revealed limitations concerning the detection of synovitis. Further research is needed to evaluate its full diagnostic potential in rheumatic diseases.

  6. Colour, vision and ergonomics.

    PubMed

    Pinheiro, Cristina; da Silva, Fernando Moreira

    2012-01-01

    This paper is based on a research project - Visual Communication and Inclusive Design-Colour, Legibility and Aged Vision, developed at the Faculty of Architecture of Lisbon. The research has the aim of determining specific design principles to be applied to visual communication design (printed) objects, in order to be easily read and perceived by all. This study target group was composed by a selection of socially active individuals, between 55 and 80 years, and we used cultural events posters as objects of study and observation. The main objective is to overlap the study of areas such as colour, vision, older people's colour vision, ergonomics, chromatic contrasts, typography and legibility. In the end we will produce a manual with guidelines and information to apply scientific knowledge into the communication design projectual practice. Within the normal aging process, visual functions gradually decline; the quality of vision worsens, colour vision and contrast sensitivity are also affected. As people's needs change along with age, design should help people and communities, and improve life quality in the present. Applying principles of visually accessible design and ergonomics, the printed design objects, (or interior spaces, urban environments, products, signage and all kinds of visually information) will be effective, easier on everyone's eyes not only for visually impaired people but also for all of us as we age.

  7. Global skin colour prediction from DNA.

    PubMed

    Walsh, Susan; Chaitanya, Lakshmi; Breslin, Krystal; Muralidharan, Charanya; Bronikowska, Agnieszka; Pospiech, Ewelina; Koller, Julia; Kovatsi, Leda; Wollstein, Andreas; Branicki, Wojciech; Liu, Fan; Kayser, Manfred

    2017-07-01

    Human skin colour is highly heritable and externally visible with relevance in medical, forensic, and anthropological genetics. Although eye and hair colour can already be predicted with high accuracies from small sets of carefully selected DNA markers, knowledge about the genetic predictability of skin colour is limited. Here, we investigate the skin colour predictive value of 77 single-nucleotide polymorphisms (SNPs) from 37 genetic loci previously associated with human pigmentation using 2025 individuals from 31 global populations. We identified a minimal set of 36 highly informative skin colour predictive SNPs and developed a statistical prediction model capable of skin colour prediction on a global scale. Average cross-validated prediction accuracies expressed as area under the receiver-operating characteristic curve (AUC) ± standard deviation were 0.97 ± 0.02 for Light, 0.83 ± 0.11 for Dark, and 0.96 ± 0.03 for Dark-Black. When using a 5-category, this resulted in 0.74 ± 0.05 for Very Pale, 0.72 ± 0.03 for Pale, 0.73 ± 0.03 for Intermediate, 0.87±0.1 for Dark, and 0.97 ± 0.03 for Dark-Black. A comparative analysis in 194 independent samples from 17 populations demonstrated that our model outperformed a previously proposed 10-SNP-classifier approach with AUCs rising from 0.79 to 0.82 for White, comparable at the intermediate level of 0.63 and 0.62, respectively, and a large increase from 0.64 to 0.92 for Black. Overall, this study demonstrates that the chosen DNA markers and prediction model, particularly the 5-category level; allow skin colour predictions within and between continental regions for the first time, which will serve as a valuable resource for future applications in forensic and anthropologic genetics.

  8. Colour preferences of juvenile turbot (Scophthalmus maximus).

    PubMed

    Li, Xian; Chi, Liang; Tian, Huiqin; Meng, Lingjie; Zheng, Jimeng; Gao, Xiaolong; Liu, Ying

    2016-03-15

    The background colour of aquaculture tanks is normally chosen based on practical experience and/or observations of fish behaviour and the growth rates achieved. However, some farmed species, including turbot, are sentient and can show a preference for a particular environment. In the current study, a self-referent colour preference device was developed and the self-referent colour preference of farmed fish investigated. In experiment 1, the background colour preference of juvenile turbot cultured under a grey background for >3months post-incubation was evaluated. Based on these results, in experiment 2, juvenile turbot were adapted to blue, pink, white, or black backgrounds for 50days and their preferences established. Meanwhile, the growth rates, feed intake, and metabolic rates (including oxygen consumption rate, and ammonia excretion rate) of the turbot were evaluated. The results showed that turbot farmed under a grey background, or after long-term white, blue, pink and black colour adaptation, always displayed a preference for a white background and a dislike for black, red, or brown backgrounds, although their body colour was greyish. Long-term adaptation influenced the frequency of juveniles selecting white, black, pink or blue backgrounds. They showed the highest growth rate, feed intake, and metabolic rates under blue and white backgrounds, and the lowest under a black background in accordance with their preferences shown in experiment 1. Although it is unclear how turbot determine their self-referent colour preferences over such a short period of time, these results indicate that dark colours are unsuitable for the aquaculture of turbot culture in terms of the welfare of the fish. Copyright © 2016 Elsevier Inc. All rights reserved.

  9. Investigating the impact of age-depended hair colour darkening during childhood on DNA-based hair colour prediction with the HIrisPlex system.

    PubMed

    Kukla-Bartoszek, Magdalena; Pośpiech, Ewelina; Spólnicka, Magdalena; Karłowska-Pik, Joanna; Strapagiel, Dominik; Żądzińska, Elżbieta; Rosset, Iwona; Sobalska-Kwapis, Marta; Słomka, Marcin; Walsh, Susan; Kayser, Manfred; Sitek, Aneta; Branicki, Wojciech

    2018-06-06

    Predictive DNA analysis of externally visible characteristics exerts an increasing influence on contemporary forensic and anthropological investigations, with pigmentation traits currently being the most advanced for predictive modelling. Since pigmentation prediction error in some cases may be due to the result of age-related hair colour darkening, and sex influence in eye colour, this study aims to investigate these less explored phenomena on a group of juvenile individuals. Pigmentation phenotypes of children between the age of 6-13 years old were evaluated, in addition to data about their hair colour during early childhood from a select number of these individuals. The HIrisPlex models for DNA-based eye and hair colour prediction were used with input from SNP genotyping using massive parallel sequencing. Analysis of the total group of 476 children showed high accuracy in blue (AUC = 0.89) and brown (AUC = 0.91) eye colour prediction, while hair colour was predicted with AUC = 0.64 for blond, AUC = 0.64 for brown and AUC = 0.97 for red. 70.8% (n = 143) of the total number of children phenotypically blond for hair colour during early childhood progressed to brown during advanced childhood. In 70.6% (n = 101) of those cases, an incorrect blond hair prediction was made during the time of analysis. A noticeable decline in AUC values for blond (from 0.76 to 0.65) and brown (from 0.72 to 0.64) were observed when comparing hair colour prediction outcomes for the phenotypes recorded for the two different time points (at the age of 2-3 and 6-13). The number of incorrect blond hair colour predictions was significantly higher in children with brown hair at age 6-13 who were blond at early childhood (n = 47, 32.9%), relative to children who had brown hair at both time points (n = 6, 9.4%). However, in 28.0% (n = 40) of children who did experience hair colour darkening, HIrisPlex provided the correct prediction for the darkened hair

  10. Colour learning when foraging for nectar and pollen: bees learn two colours at once.

    PubMed

    Muth, Felicity; Papaj, Daniel R; Leonard, Anne S

    2015-09-01

    Bees are model organisms for the study of learning and memory, yet nearly all such research to date has used a single reward, nectar. Many bees collect both nectar (carbohydrates) and pollen (protein) on a single foraging bout, sometimes from different plant species. We tested whether individual bumblebees could learn colour associations with nectar and pollen rewards simultaneously in a foraging scenario where one floral type offered only nectar and the other only pollen. We found that bees readily learned multiple reward-colour associations, and when presented with novel floral targets generalized to colours similar to those trained for each reward type. These results expand the ecological significance of work on bee learning and raise new questions regarding the cognitive ecology of pollination. © 2015 The Author(s).

  11. Interactive imagery and colour in paired-associate learning.

    PubMed

    Wilton, Richard N

    2006-01-01

    In four experiments participants were instructed to imagine scenes that described either an animal interacting with a coloured object or scenes in which the animal and coloured object were independent of each other. Participants were then given the name of the animal and required to select the name of the object and its colour. The results showed that the classic interactive imagery effect was greater for the selection of the name of the object than it was for colour. In Experiments 2, 3, and 4, additional measures were taken which suggest that the effect for colour is dependent upon the retrieval of other features of the object (e.g., its form). Thus it is argued that there is no primary interactive imagery effect for colour. The results were predicted by a version of the shared information hypothesis. The implications of the results for alternative theories are also considered.

  12. Selective interference reveals dissociation between memory for location and colour.

    PubMed

    Vuontela, V; Rämä, P; Raninen, A; Aronen, H J; Carlson, S

    1999-08-02

    The aim was to study whether there is indication of a dissociation in processing of visuospatial and colour information in working memory in humans. Experimental subjects performed visuospatial and colour n-back tasks with and without visuospatial and colour distractive stimuli presented in the middle of the delay period to specifically affect mnemonic processing of task-related information. In the high memory-load condition, the visuospatial, but not the colour, task was selectively disrupted by visuospatial but not colour distractors. When subvocal rehearsal of the memoranda in the colour task was prevented by articulatory suppression; colour task performance was also selectively disrupted by distractors qualitatively similar to the memoranda. The results support the suggestion that visual working memory for location is processed separate from that for colour.

  13. Optimality of the basic colour categories for classification

    PubMed Central

    Griffin, Lewis D

    2005-01-01

    Categorization of colour has been widely studied as a window into human language and cognition, and quite separately has been used pragmatically in image-database retrieval systems. This suggests the hypothesis that the best category system for pragmatic purposes coincides with human categories (i.e. the basic colours). We have tested this hypothesis by assessing the performance of different category systems in a machine-vision task. The task was the identification of the odd-one-out from triples of images obtained using a web-based image-search service. In each triple, two of the images had been retrieved using the same search term, the other a different term. The terms were simple concrete nouns. The results were as follows: (i) the odd-one-out task can be performed better than chance using colour alone; (ii) basic colour categorization performs better than random systems of categories; (iii) a category system that performs better than the basic colours could not be found; and (iv) it is not just the general layout of the basic colours that is important, but also the detail. We conclude that (i) the results support the plausibility of an explanation for the basic colours as a result of a pressure-to-optimality and (ii) the basic colours are good categories for machine vision image-retrieval systems. PMID:16849219

  14. De-Dopplerization of Acoustic Measurements

    DTIC Science & Technology

    2017-08-10

    band energy obtained from fractional octave band digital filters generates a de-Dopplerized spectrum without complex resampling algorithms. An...energy obtained from fractional octave band digital filters generates a de-Dopplerized spectrum without complex resampling algorithms. An equation...fractional octave representation and smearing that occurs within the spectrum11, digital filtering techniques were not considered by these earlier

  15. Analysis and prediction of Doppler noise during solar conjunctions

    NASA Technical Reports Server (NTRS)

    Berman, A. L.; Rockwell, S. T.

    1975-01-01

    The results of a study of Doppler data noise during solar conjunctions were presented. During the first half of 1975, a sizeable data base of Doppler data noise (estimates) for the Pioneer 10, Pioneer 11, and Helios 1 solar conjunctions was accumulated. To analyze this data, certain physical assumptions are made, leading to the development of a geometric parameter ("ISI") which correlates strongly with Doppler data noise under varying sun-earth-spacecraft geometries. Doppler noise models are then constructed from this parameter, resulting in the newfound ability to predict Doppler data noise during solar conjunctions, and hence to additionally be in a position to validate Doppler data acquired during solar conjunctions.

  16. The effects of colour and valence on news evaluation.

    PubMed

    Kaspar, Kai; Grümmer, Melanie; Kießler, Antje; Neuß, Celina; Schröter, Franziska

    2017-12-01

    Research across different fields of psychology has reported effects of colour cues on a variety of cognitive processes. Especially, the colour red has been shown to have striking influences. In the context of media reception, however, colour effects have been widely neglected so far. This study made a first step in this direction by investigating the effects of the colour red (compared with blue and grey) on the way news articles are evaluated. Two types of news were framed by a coloured border while the valence of the news content additionally varied. Based on 369 participants who read and evaluated the news articles online, we observed effects for colour cues and news valence in the absence of an interaction effect, indicating that the colour red induced approach motivation. However, only the contrast between red and grey reached statistical significance, indicating that chromatic and achromatic colours may differ in their perceived visual saliency. Overall, these results provide an important complement to previous studies and have practical implications for media researchers and producers. © 2015 International Union of Psychological Science.

  17. Conjunctions of colour, luminance and orientation: the role of colour and luminance contrast on saliency and proximity grouping in texture segregation.

    PubMed

    Leonards, U; Singer, W

    2000-01-01

    To examine whether perceptual grouping on the basis of orientation can be performed simultaneously with or only subsequently to grouping according to colour or luminance, we tested whether subjects are able to segregate arrays of texture elements that differ from surrounding elements by conjunctions of either (i) colour and orientation, or (ii) luminance contrast and orientation, or (iii) luminance contrast polarity and orientation. Subjects were able to use conjunctions between luminance and orientation for segregation but not conjunctions between colour or contrast polarity and orientation. Our results suggest that (i) in agreement with earlier findings, there seem to exist no specific conjunction detectors for colour and orientation or contrast polarity and orientation, and (ii) when orientation defined textures are to be distinguished by virtue of differences in luminance, colour, or contrast polarity, luminance provides a much stronger cue than colour or contrast polarity for saliency-based orientation grouping.

  18. Why background colour matters to bees and flowers.

    PubMed

    Bukovac, Zoë; Shrestha, Mani; Garcia, Jair E; Burd, Martin; Dorin, Alan; Dyer, Adrian G

    2017-05-01

    Flowers are often viewed by bee pollinators against a variety of different backgrounds. On the Australian continent, backgrounds are very diverse and include surface examples of all major geological stages of the Earth's history, which have been present during the entire evolutionary period of Angiosperms. Flower signals in Australia are also representative of typical worldwide evolutionary spectral adaptations that enable successful pollination. We measured the spectral properties of 581 natural surfaces, including rocks, sand, green leaves, and dry plant materials, sampled from tropical Cairns through to the southern tip of mainland Australia. We modelled in a hexagon colour space, how interactions between background spectra and flower-like colour stimuli affect reliable discrimination and detection in bee pollinators. We calculated the extent to which a given locus would be conflated with the loci of a different flower-colour stimulus using empirically determined colour discrimination regions for bee vision. Our results reveal that whilst colour signals are robust in homogeneous background viewing conditions, there could be significant pressure on plant flowers to evolve saliently-different colours to overcome background spectral noise. We thus show that perceptual noise has a large influence on how colour information can be used in natural conditions.

  19. Biventricular and atrial diastolic function assessment using conventional echocardiography and tissue-Doppler imaging in adults with Marfan syndrome.

    PubMed

    Kiotsekoglou, Anatoli; Moggridge, James C; Bijnens, Bart H; Kapetanakis, Venediktos; Alpendurada, Francisco; Mullen, Michael J; Saha, Samir; Nassiri, Dariush K; Camm, John; Sutherland, George R; Child, Anne H

    2009-12-01

    Previous studies provided evidence about left ventricular systolic and diastolic dysfunction in adults with Marfan syndrome (MFS). However, in the literature, data on right ventricular and bi-atrial diastolic function are limited. We aimed to investigate whether, in the absence of significant valvular disease, diastolic dysfunction is present not only in both ventricles but also in the atrial cavities. Seventy-two adult unoperated MFS patients and 73 controls without significant differences in age, sex, and body surface area from the patient group were studied using two-dimensional, pulsed, and colour-Doppler and tissue-Doppler imaging (TDI). Biventricular early filling measurements were significantly decreased in MFS patients when compared with controls (P < 0.001). Pulsed TDI early filling measurements obtained from five mitral annular regions and over the lateral tricuspid valve corner were significantly reduced in the patient group (P < 0.001). Indices reflecting atrial function at the reservoir, conduit and contractile phases were also significantly decreased in MFS patients (P < 0.001). This study demonstrated significant biventricular diastolic and biatrial systolic and diastolic dysfunction in MFS patients. Our findings suggest that MFS affects diastolic function independently. Diastolic abnormalities could be attributed to fibrillin-1 deficiency and dysregulation of transforming growth factor-beta activity in the cardiac extracellular matrix.

  20. Worldwide patterns of bird colouration on islands.

    PubMed

    Doutrelant, Claire; Paquet, Matthieu; Renoult, Julien P; Grégoire, Arnaud; Crochet, Pierre-André; Covas, Rita

    2016-05-01

    Island environments share distinctive characteristics that offer unique opportunities to investigate parallel evolution. Previous research has produced evidence of an island syndrome for morphological traits, life-history strategies and ecological niches, but little is known about the response to insularity of other important traits such as animal signals. Here, we tested whether birds' plumage colouration is part of the island syndrome. We analysed with spectrophotometry the colouration of 116 species endemic to islands and their 116 closest mainland relatives. We found a pattern of reduced brightness and colour intensity for both sexes on islands. In addition, we found a decrease in the number of colour patches on islands that, in males, was associated with a decrease in the number of same-family sympatric species. These results demonstrate a worldwide pattern of parallel colour changes on islands and suggest that a relaxation of selection on species recognition may be one of the mechanisms involved. © 2016 John Wiley & Sons Ltd/CNRS.

  1. Colour stability of aesthetic brackets: ceramic and plastic.

    PubMed

    Filho, Hibernon Lopes; Maia, Lúcio Henrique; Araújo, Marcus V; Eliast, Carlos Nelson; Ruellas, Antônio Carlos O

    2013-05-01

    The colour stability of aesthetic brackets may differ according to their composition, morphology and surface property, which may consequently influence their aesthetic performance. To assess the colour stability of aesthetic brackets (ceramic and plastic) after simulating aging and staining. Twelve commercially manufactured ceramic brackets and four different plastic brackets were assessed. To determine possible colour change (change of E*(ab)) and the value of the NBS (National Bureau of Standards) unit system, spectrophotometric colour measurements for CIE L*, a* and b* were taken before and after the brackets were aged and stained. Statistical analysis was undertaken using a one-way ANOVA analysis of variance and a Tukey multiple comparison test (alpha = 0.05). The colour change between the various (ceramic and plastic) materials was not significant (p > 0.05), but still varied significantly (p < 0.001) between the brackets of the same composition or crystalline structure and among commercial brands. Colour stability cannot be confirmed simply by knowing the type of material and crystalline composition or structure.

  2. Economic analysis of bedside ultrasonography (US) implementation in an Internal Medicine department.

    PubMed

    Testa, Americo; Francesconi, Andrea; Giannuzzi, Rosangela; Berardi, Silvia; Sbraccia, Paolo

    2015-12-01

    The economic crisis, the growing healthcare demand, and Defensive Medicine wastefulness, strongly recommend the restructuring of the entire medical network. New health technology, such as bedside ultrasonography, might successfully integrate the clinical approach optimizing the use of limited resources, especially in a person-oriented vision of medicine. Bedside ultrasonography is a safe and reliable technique, with worldwide expanding employment in various clinical settings, being considered as "the stethoscope of the 21st century". However, at present, bedside ultrasonography lacks economic analysis. We performed a Cost-Benefit Analysis "ex ante", with a break-even point computing, of bedside ultrasonography implementation in an Internal Medicine department in the mid-term. Number and kind estimation of bedside ultrasonographic studies were obtained by a retrospective study, whose data results were applied to the next 3-year period (foresight study). All 1980 foreseen bedside examinations, with prevailing multiorgan ultrasonographic studies, were considered to calculate direct and indirect costs, while specific and generic revenues were considered only after the first semester. Physician professional training, equipment purchase and working time represented the main fixed and variable cost items. DRG increase/appropriateness, hospitalization stay shortening and reduction of traditional ultrasonography examination requests mainly impacted on calculated revenues. The break-even point, i.e. the volume of activity at which revenues exactly equal total incurred costs, was calculated to be 734 US examinations, corresponding to € 81,998 and the time considered necessary to reach it resulting 406 days. Our economic analysis clearly shows that bedside ultrasonography implementation in clinical daily management of an Internal Medicine department can produce consistent savings, or economic profit according to managerial choices (i.e., considering public or private targets

  3. Examples of Radiation-Emitting Products

    MedlinePlus

    ... UltrasonographyDoppler ultrasound • Color doppler ultrasound • Hyperthermia • Diathermy/physical therapy • Bone healing • Lithotripsy • Phacoemulsifier • Needle guide • Bone density measuring • Geriatric bath (ultrasound) • Hearing aid • Many scientific uses • Nondestructive ...

  4. [Optic mixing of colours in Seurat's painting].

    PubMed

    Cernea, Paul

    2002-01-01

    Georges Seurat is the initiator and master of the divisionism. He founds the neoimpressionism current that tries to reproduce the nature exclusively through coloured vibration. Seurat applies the colours in small touches uniformly distributed on the canvas; the colours merge if they are looked by a certain distance, through optical interference. When the spectator approaches from the picture, the special frequency decreases, the optical merging does not appear and the onlooker looks a lot of coloured spots. When the spectator moves away from the picture, the optical interference appears and the clarity of the image becomes perfectly. This current opened the way of the future's modern painting performed by Cézanne, Renoir, Van Gogh.

  5. Perfusion dynamics assessment with Power Doppler ultrasound in skeletal muscle during maximal and submaximal cycling exercise.

    PubMed

    Heres, H M; Schoots, T; Tchang, B C Y; Rutten, M C M; Kemps, H M C; van de Vosse, F N; Lopata, R G P

    2018-06-01

    Assessment of limitations in the perfusion dynamics of skeletal muscle may provide insight in the pathophysiology of exercise intolerance in, e.g., heart failure patients. Power doppler ultrasound (PDUS) has been recognized as a sensitive tool for the detection of muscle blood flow. In this volunteer study (N = 30), a method is demonstrated for perfusion measurements in the vastus lateralis muscle, with PDUS, during standardized cycling exercise protocols, and the test-retest reliability has been investigated. Fixation of the ultrasound probe on the upper leg allowed for continuous PDUS measurements. Cycling exercise protocols included a submaximal and an incremental exercise to maximal power. The relative perfused area (RPA) was determined as a measure of perfusion. Absolute and relative reliability of RPA amplitude and kinetic parameters during exercise (onset, slope, maximum value) and recovery (overshoot, decay time constants) were investigated. A RPA increase during exercise followed by a signal recovery was measured in all volunteers. Amplitudes and kinetic parameters during exercise and recovery showed poor to good relative reliability (ICC ranging from 0.2-0.8), and poor to moderate absolute reliability (coefficient of variation (CV) range 18-60%). A method has been demonstrated which allows for continuous (Power Doppler) ultrasonography and assessment of perfusion dynamics in skeletal muscle during exercise. The reliability of the RPA amplitudes and kinetics ranges from poor to good, while the reliability of the RPA increase in submaximal cycling (ICC = 0.8, CV = 18%) is promising for non-invasive clinical assessment of the muscle perfusion response to daily exercise.

  6. Are dogs red-green colour blind?

    PubMed

    Siniscalchi, Marcello; d'Ingeo, Serenella; Fornelli, Serena; Quaranta, Angelo

    2017-11-01

    Neurobiological and molecular studies suggest a dichromatic colour vision in canine species, which appears to be similar to that of human red-green colour blindness. Here, we show that dogs exhibit a behavioural response similar to that of red-green blind human subjects when tested with a modified version of a test commonly used for the diagnosis of human deuteranopia (i.e. the Ishihara's test). Besides contributing to increasing the knowledge about the perceptual ability of dogs, the present work describes for the first time, to our knowledge, a method that can be used to assess colour vision in the animal kingdom.

  7. Evaluation of clinical breast examination and breast ultrasonography among pregnant women in Abakaliki, Nigeria

    PubMed Central

    Ezeonu, Paul Olisaemeka; Ajah, Leonard Ogbonna; Onoh, Robinson Chukwudi; Lawani, Lucky Osaheni; Enemuo, Vincent Chidi; Agwu, Uzoma MaryRose

    2015-01-01

    Background Breast cancer in pregnancy accounts for 2%–3% of all breast cancers. The increased vascularity and lymphatic drainage from the breast during pregnancy potentiate the metastatic spread of the cancer to the regional lymph nodes. However, the increased breast density in pregnancy makes it difficult to detect breast lesions early. Aim To evaluate and compare the detection rate of breast lesions using clinical breast examination (CBE) and breast ultrasonography among pregnant women. Methodology A cross-sectional comparative study involving antenatal clinic attendees at the Federal Teaching Hospital, Abakaliki, was conducted between March 3, 2014, and December 31, 2014. CBE and breast ultrasonography were done in the participants at booking and repeated at 6 weeks postpartum. Fine-needle aspiration cytology and histology were done in women with suspicious breast lesions on CBE or breast ultrasonography or both. Data analysis was both descriptive and inferential at the 95% confidence level using the Statistical Package for the Social Sciences (SPSS) software version 17.0. Test of significance was done using chi-square test. A P-value of less than or equal to 0.05 was considered statistically significant. Results A total of 320 pregnant women participated in the study. Of these, 267 (83.4%) were aware of breast cancer. Although more lesions were detected with breast ultrasonography than by CBE, there was no statistically significant difference between them (25 versus 17; P=0.26). The histology of the lesions revealed 21 benign lesions and 4 normal breast tissues. The sensitivity of breast ultrasonography was 95.2%, while that of CBE was 66.7%. The specificity, positive predictive value, and negative predictive value were similar between CBE and breast ultrasonography. Conclusion The detection rates of breast lesions by both CBE and breast ultrasonography were equivalent during pregnancy and 6 weeks postpartum, making CBE a convenient and very cost

  8. Colour distributions in E-S0 galaxies . IV. Colour data and dust in E's from Nieto's B, R frames

    NASA Astrophysics Data System (ADS)

    Michard, R.

    1999-06-01

    The B-R colours distributions (with R in Cousins's system) have been measured in 44 E classified galaxies in the Local Supercluster, from pairs of frames collected by Nieto and co-workers in 1989-91. These are nearly all from the CFHT, and of sub-arsec resolution. Great attention has been given to the effects of unequal PSF's in the B and R frames upon colour distributions near centre; such effects are illustrated from model calculations and from pseudo-colours obtained from pairs of frames taken in the same band but with different seeing conditions. Appropriate corrections were systematically applied in order to derive central colours and inner gradients, although still affected by the limited resolution of the frames. The radial colour distributions have been measured in more detail than usual, considering separately the near major axis and near minor axis regions of the isophotal contours. Azimuthal colour distributions, in rings limited by selected isophotes, were also obtained. Dust ``patterns", i.e. patches, lanes, arcs, ..., have been detected and mapped from the colour distributions. An ad hoc dust pattern importance index (or DPII) in a scale of 0 to 3, has been introduced to qualify their size and contrast. We have tried to find evidence of a diffuse dust concentration towards the disk, if one is apparent. Positive results (noted by the dd symbol) have been obtained for disky E's, whenever the inclination of their disk to the line of sight is large enough, and eventually also in the small isolated disks sometimes present in both boxy and disky galaxies. The red central peak occurring in many E-galaxies might be the signature of a central concentration of dust, also in cases where this peak is isolated rather than embedded in some extensive colour pattern. The properties of the near centre colour profiles have been related to a classification of nuclear photometric profiles into ``flat topped" and ``sharply peaked" (equivalent to ``core-like" and ``power

  9. What Colour Is a Shadow?

    ERIC Educational Resources Information Center

    Hughes, S. W.

    2009-01-01

    What colour is a shadow? Black, grey, or some other colour? This article describes how to use a digital camera to test the hypothesis that a shadow under a clear blue sky has a blue tint. A white sheet of A4 paper was photographed in full sunlight and in shadow under a clear blue sky. The images were analysed using a shareware program called…

  10. Validation of continuous-wave Doppler echocardiographic measurements of mitral and tricuspid prosthetic valve gradients: a simultaneous Doppler-catheter study.

    PubMed

    Wilkins, G T; Gillam, L D; Kritzer, G L; Levine, R A; Palacios, I F; Weyman, A E

    1986-10-01

    For patients with stenotic native valves, the modified Bernoulli equation (delta P = 4V2) may be applied to Doppler-measured transvalvular velocities to yield an accurate estimate of transvalvular gradients. Although it would be useful if the same approach could be used for those with stenotic prosthetic valves, no previous study has validated the Doppler technique in this setting. We therefore recorded simultaneous continuous-wave Doppler flow profiles and transvalvular manometric gradients in 12 catheterized patients in whom all atrial and ventricular pressures were directly measured (transseptal left atrial catheterization and transthoracic ventricular puncture were performed where necessary). A total of 13 prostheses were studied: 11 mitral (seven porcine, three Starr-Edwards, and one Björk-Shiley) and two tricuspid (one porcine and one Björk-Shiley). The Doppler-determined mean gradient was calculated as the mean of the instantaneous gradients (delta P = 4V2) at 10 msec intervals throughout diastole. The correlation of simultaneous Doppler (DMG) and manometric mean gradients (MG) for the whole group (n = 13) demonstrated a highly significant relationship (MG = 1.07 DMG + 0.28; r = .96, p = .0001). The correlation was equally good for porcine valves alone (n = 8) (MG = 1.06 DMG + 0.55; r = .96, p = .001) and for mechanical valves alone (n = 5) (MG = 1.06 DMG - 0.04; r = .93, p = .02). In a subset of patients without regurgitation (n = 8), prosthetic valve areas were estimated by two Doppler methods originally described by Holen and Hatle, as well as by the invasive Gorlin method. As expected from theoretical considerations, a close correlation was not demonstrated between results of the Gorlin method and those of either Hatle's Doppler method (r = .65, fp = NS) or Holen's method (r = .14, p = NS). Comparison of the results of the two Doppler methods yielded a somewhat closer correlation (r = .73, p less than or equal to .05). These results suggest that in

  11. Inverse Doppler Effects in Broadband Acoustic Metamaterials

    PubMed Central

    Zhai, S. L.; Zhao, X. P.; Liu, S.; Shen, F. L.; Li, L. L.; Luo, C. R.

    2016-01-01

    The Doppler effect refers to the change in frequency of a wave source as a consequence of the relative motion between the source and an observer. Veselago theoretically predicted that materials with negative refractions can induce inverse Doppler effects. With the development of metamaterials, inverse Doppler effects have been extensively investigated. However, the ideal material parameters prescribed by these metamaterial design approaches are complex and also challenging to obtain experimentally. Here, we demonstrated a method of designing and experimentally characterising arbitrary broadband acoustic metamaterials. These omni-directional, double-negative, acoustic metamaterials are constructed with ‘flute-like’ acoustic meta-cluster sets with seven double meta-molecules; these metamaterials also overcome the limitations of broadband negative bulk modulus and mass density to provide a region of negative refraction and inverse Doppler effects. It was also shown that inverse Doppler effects can be detected in a flute, which has been popular for thousands of years in Asia and Europe. PMID:27578317

  12. Inverse Doppler Effects in Broadband Acoustic Metamaterials

    NASA Astrophysics Data System (ADS)

    Zhai, S. L.; Zhao, X. P.; Liu, S.; Shen, F. L.; Li, L. L.; Luo, C. R.

    2016-08-01

    The Doppler effect refers to the change in frequency of a wave source as a consequence of the relative motion between the source and an observer. Veselago theoretically predicted that materials with negative refractions can induce inverse Doppler effects. With the development of metamaterials, inverse Doppler effects have been extensively investigated. However, the ideal material parameters prescribed by these metamaterial design approaches are complex and also challenging to obtain experimentally. Here, we demonstrated a method of designing and experimentally characterising arbitrary broadband acoustic metamaterials. These omni-directional, double-negative, acoustic metamaterials are constructed with ‘flute-like’ acoustic meta-cluster sets with seven double meta-molecules; these metamaterials also overcome the limitations of broadband negative bulk modulus and mass density to provide a region of negative refraction and inverse Doppler effects. It was also shown that inverse Doppler effects can be detected in a flute, which has been popular for thousands of years in Asia and Europe.

  13. From spectral information to animal colour vision: experiments and concepts.

    PubMed

    Kelber, Almut; Osorio, Daniel

    2010-06-07

    Many animals use the spectral distribution of light to guide behaviour, but whether they have colour vision has been debated for over a century. Our strong subjective experience of colour and the fact that human vision is the paradigm for colour science inevitably raises the question of how we compare with other species. This article outlines four grades of 'colour vision' that can be related to the behavioural uses of spectral information, and perhaps to the underlying mechanisms. In the first, even without an (image-forming) eye, simple organisms can compare photoreceptor signals to locate a desired light environment. At the next grade, chromatic mechanisms along with spatial vision guide innate preferences for objects such as food or mates; this is sometimes described as wavelength-specific behaviour. Here, we compare the capabilities of di- and trichromatic vision, and ask why some animals have more than three spectral types of receptors. Behaviours guided by innate preferences are then distinguished from a grade that allows learning, in part because the ability to learn an arbitrary colour is evidence for a neural representation of colour. The fourth grade concerns colour appearance rather than colour difference: for instance, the distinction between hue and saturation, and colour categorization. These higher-level phenomena are essential to human colour perception but poorly known in animals, and we suggest how they can be studied. Finally, we observe that awareness of colour and colour qualia cannot be easily tested in animals.

  14. Marked colour divergence in the gliding membranes of a tropical lizard mirrors population differences in the colour of falling leaves

    PubMed Central

    Klomp, D. A.; Stuart-Fox, D.; Das, I.; Ord, T. J.

    2014-01-01

    Populations of the Bornean gliding lizard, Draco cornutus, differ markedly in the colour of their gliding membranes. They also differ in local vegetation type (mangrove forest versus lowland rainforest) and consequently, the colour of falling leaves (red and brown/black in mangrove versus green, brown and black in rainforest). We show that the gliding membranes of these lizards closely match the colours of freshly fallen leaves in the local habitat as they appear to the visual system of birds (their probable predators). Furthermore, gliding membranes more closely resembled colours of local fallen leaves than standing foliage or fallen leaves in the other population's habitat. This suggests that the two populations have diverged in gliding membrane coloration to match the colours of their local falling leaves, and that mimicking falling leaves is an adaptation that functions to reduce predation by birds. PMID:25540157

  15. Doppler term in the galaxy two-point correlation function: Wide-angle, velocity, Doppler lensing and cosmic acceleration effects

    NASA Astrophysics Data System (ADS)

    Raccanelli, Alvise; Bertacca, Daniele; Jeong, Donghui; Neyrinck, Mark C.; Szalay, Alexander S.

    2018-03-01

    We study the parity-odd part (that we shall call Doppler term) of the linear galaxy two-point correlation function that arises from wide-angle, velocity, Doppler lensing and cosmic acceleration effects. As it is important at low redshift and at large angular separations, the Doppler term is usually neglected in the current generation of galaxy surveys. For future wide-angle galaxy surveys, however, we show that the Doppler term must be included. The effect of these terms is dominated by the magnification due to relativistic aberration effects and the slope of the galaxy redshift distribution and it generally mimics the effect of the local type primordial non-Gaussianity with the effective nonlinearity parameter fNLeff of a few; we show that this would affect forecasts on measurements of fNL at low-redshift. Our results show that a survey at low redshift with large number density over a wide area of the sky could detect the Doppler term with a signal-to-noise ratio of ∼ 1 - 20, depending on survey specifications.

  16. Micro-Doppler analysis of multiple frequency continuous wave radar signatures

    NASA Astrophysics Data System (ADS)

    Anderson, Michael G.; Rogers, Robert L.

    2007-04-01

    Micro-Doppler refers to Doppler scattering returns produced by non rigid-body motion. Micro-Doppler gives rise to many detailed radar image features in addition to those associated with bulk target motion. Targets of different classes (for example, humans, animals, and vehicles) produce micro-Doppler images that are often distinguishable even by nonexpert observers. Micro-Doppler features have great potential for use in automatic target classification algorithms. Although the potential benefit of using micro-Doppler in classification algorithms is high, relatively little experimental (non-synthetic) micro-Doppler data exists. Much of the existing experimental data comes from highly cooperative targets (human or vehicle targets directly approaching the radar). This research involved field data collection and analysis of micro-Doppler radar signatures from non-cooperative targets. The data was collected using a low cost Xband multiple frequency continuous wave (MFCW) radar with three transmit frequencies. The collected MFCW radar signatures contain data from humans, vehicles, and animals. The presented data includes micro-Doppler signatures previously unavailable in the literature such as crawling humans and various animal species. The animal micro-Doppler signatures include deer, dog, and goat datasets. This research focuses on the analysis of micro-Doppler from noncooperative targets approaching the radar at various angles, maneuvers, and postures.

  17. [Venous Doppler color echography: importance and inconveniences].

    PubMed

    Laroche, J P; Dauzat, M; Muller, G; Janbon, C

    1993-01-01

    Color Doppler is a technique which performs a real-time opacification of the vascular system with blue indicating reverse flow and red indicating forward flow (directional color coding). In venous pathology, the use of color Doppler improves significantly the anatomical evaluation of the inferior vena cava, the iliac vein, the deep femoral vein, and the sural system. Color Doppler facilitates the study of deep venous thrombosis (providing useful information to differentiate ancient from most recent thrombus) and also the study of post-thrombotic conditions (assessment of reverse flow, repermeation phenomena). Finally, color Doppler produces a better insight for the study of varicose veins, especially with regard to mapping, identification of communicante veins, and study of the external saphenous vein.

  18. Penile Fracture: Our Experience in a Tertiary Care Hospital.

    PubMed

    Mahapatra, Rajkumar Singha; Kundu, Anup Kumar; Pal, Dilip Kumar

    2015-08-01

    Penile fracture is rare, but it is a urological emergency that always requires immediate attention. Moreover, penile fracture has been reported more frequently in recent years. It may have devastating physical, functional, and psychological consequences if not properly managed in time. The objective of this study was to highlight the causes, clinical presentation, and outcomes of cases of penile fracture. This was a prospective observational study extending from November 2012 to November 2014. Each patient underwent a thorough clinical evaluation and received proper treatment. Twenty patients with penile fracture, aged 19 to 56 years (mean, 28 years) were evaluated in this study. Vaginal intercourse was the most common mechanism of injury. Most of the patients (95%) were diagnosed clinically with a proper history and clinical examination. Nineteen patients were treated surgically. The patients underwent six months of follow-up, and were evaluated with local examinations, questionnaires, and colour Doppler ultrasonography as necessary. Although penile fracture is an under-reported urological emergency, its incidence is increasing. It is usually diagnosed based on a clinical examination, but ultrasonography can be very helpful in diagnosis. Especially in cases where treatment is delayed, surgery is preferable to conservative management, because it is associated with better outcomes and fewer long-term complications.

  19. Penile Fracture: Our Experience in a Tertiary Care Hospital

    PubMed Central

    Mahapatra, Rajkumar Singha; Kundu, Anup Kumar

    2015-01-01

    Purpose Penile fracture is rare, but it is a urological emergency that always requires immediate attention. Moreover, penile fracture has been reported more frequently in recent years. It may have devastating physical, functional, and psychological consequences if not properly managed in time. Materials and Methods The objective of this study was to highlight the causes, clinical presentation, and outcomes of cases of penile fracture. This was a prospective observational study extending from November 2012 to November 2014. Each patient underwent a thorough clinical evaluation and received proper treatment. Results Twenty patients with penile fracture, aged 19 to 56 years (mean, 28 years) were evaluated in this study. Vaginal intercourse was the most common mechanism of injury. Most of the patients (95%) were diagnosed clinically with a proper history and clinical examination. Nineteen patients were treated surgically. The patients underwent six months of follow-up, and were evaluated with local examinations, questionnaires, and colour Doppler ultrasonography as necessary. Conclusions Although penile fracture is an under-reported urological emergency, its incidence is increasing. It is usually diagnosed based on a clinical examination, but ultrasonography can be very helpful in diagnosis. Especially in cases where treatment is delayed, surgery is preferable to conservative management, because it is associated with better outcomes and fewer long-term complications. PMID:26331126

  20. Is colour modulation an independent factor in human visual photosensitivity?

    PubMed

    Parra, Jaime; Lopes da Silva, Fernando H; Stroink, Hans; Kalitzin, Stiliyan

    2007-06-01

    Considering that the role of colour in photosensitive epilepsy (PSE) remains unclear, we designed a study to determine the potential of different colours, colour combinations and white light to trigger photoparoxysmal responses (PPRs) under stringent controlled conditions. After assessing their photosensitivity to stroboscopic white light and black and white patterns, we studied 43 consecutive PSE patients (mean age 19 years, 34 women), using a specially designed colour stimulator. Stimuli included: pulse trains between 10 and 30 Hz of white light and of all primary colours, and also isoluminant alternating time-sequences of colours. Illuminance was kept constant at 100 lux. A progressive stepwise increase of the modulation-depth (MD) of the stimuli was used to determine PPRs threshold. Whereas all the 43 patients were found to be sensitive during the stroboscopic and pattern protocol, only 25 showed PPRs (Waltz's score >2) at least in one session when studied with the colour stimulator. Coloured stimuli elicited PPRs in all these patients, whereas white light did so only in 17 patients. Of the primary colours, red elicited more PPRs (54 in 22 patients) and at a lower MD (max Z-score 0.93 at 10 Hz). Of the alternating sequences, the red-blue was the most provocative stimulus, especially below 30 Hz (100% of patients, max Z-score: 1.65 at 15 Hz). Blue-green was the least provocative stimulus, since it elicited only seven PPRs in seven (28%) patients (max Z-score 0.44 at 10 Hz). Sensitivity to alternating colours was not correlated to sensitivity to individual colours. We conclude that colour sensitivity follows two different mechanisms: one, dependent on colour modulation, plays a role at lower frequencies (<30 Hz). Another, dependent on single-colour light intensity modulation correlates to white light sensitivity and is activated at higher frequencies. Our results suggest that the prescription of spectacles with coloured lenses, tailored to the patient, can be an