Science.gov

Sample records for complete membranous occlusion

  1. Different Occlusal Schemes in a Persistent Protruding Complete Denture Wearer.

    PubMed

    Iegami, Carolina Mayumi; Lopes, Danilo de Melo; Nakamae, Atlas Edson Moleros; Uehara, Priscila Nakasone; Tamaki, Regina

    2016-01-01

    Different types of artificial teeth and occlusal designs can be used in complete dentures. Bilateral balanced occlusion, lingualized occlusion, canine guidance, and monoplane are the main occlusal designs; however there is no agreement on which tooth arrangement is ideal for achieving success in complete dentures. This report presents an alternative for persistent involuntary protruding complete denture wearers through the use of artificial teeth with higher cusps. Due to an old and worn pair of complete dentures, the patient had the habit of protruding. New dentures were made with Biotone artificial teeth and in the trial session, the patient would still protrude. A new set was made with Premium artificial teeth, which present higher cusps. With these dentures, the involuntary protrusion did not occur. From the delivery to the follow-up sessions, the patient stopped protruding. PMID:27069698

  2. Different Occlusal Schemes in a Persistent Protruding Complete Denture Wearer

    PubMed Central

    Iegami, Carolina Mayumi; Lopes, Danilo de Melo; Nakamae, Atlas Edson Moleros; Uehara, Priscila Nakasone; Tamaki, Regina

    2016-01-01

    Different types of artificial teeth and occlusal designs can be used in complete dentures. Bilateral balanced occlusion, lingualized occlusion, canine guidance, and monoplane are the main occlusal designs; however there is no agreement on which tooth arrangement is ideal for achieving success in complete dentures. This report presents an alternative for persistent involuntary protruding complete denture wearers through the use of artificial teeth with higher cusps. Due to an old and worn pair of complete dentures, the patient had the habit of protruding. New dentures were made with Biotone artificial teeth and in the trial session, the patient would still protrude. A new set was made with Premium artificial teeth, which present higher cusps. With these dentures, the involuntary protrusion did not occur. From the delivery to the follow-up sessions, the patient stopped protruding. PMID:27069698

  3. Reestablishment of Occlusal Vertical Dimension in Complete Denture Wearing in Two Stages

    PubMed Central

    Marin, Danny Omar Mendoza; Leite, Andressa Rosa Perin; de Oliveira Junior, Norberto Martins; Compagnoni, Marco Antonio; Pero, Ana Carolina; Arioli Filho, João Neudenir

    2015-01-01

    The assessment and reestablishment of the occlusal vertical dimension (OVD) are considered important factors in the treatment of complete denture wearers. The long-time use of a complete denture can result in jaw displacement due to abrasion of the artificial teeth and residual ridge resorption, causing esthetic complications. Most patients with old dentures and incorrect OVD accept reestablishment of the OVD with new complete dentures, even if they were used to their old dentures. The present clinical report describes a method of gradual reestablishment of OVD using a diagnostic acrylic splint on artificial teeth in old complete dentures before the manufacture of new complete dentures. Clinical Significance. The use of a reversible treatment for reestablishment of the OVD in old complete dentures with a diagnostic occlusal acrylic splint allows for the reestablishment of the intermaxillary relationship, providing physiological conditions of masticatory performance associated with the recovery of facial esthetics in edentulous patients. PMID:26587296

  4. Use of Hydrocoil in small aneurysms: procedural safety, treatment efficacy and factors predicting complete occlusion.

    PubMed

    Williams, Amanda; Millar, John; Ditchfield, Adam; Vundavalli, Sriram; Barker, Simon

    2014-01-01

    Coil technology has been directed to reduce recurrence rates and we have seen the introduction of trials comparing the efficacy of surface modified versus bare platinum coils (BPC). This article reports on one treatment strategy in the treatment of small aneurysms by the placement of Hydrocoil across the neck of the aneurysm. Procedural safety, treatment efficacy and factors which predict complete occlusion are evaluated. We retrospectively identified a subgroup of small aneurysms treated over a four-year period. Analysis comparing aneurysms treated with Hydrocoil and BPC versus Hydrocoil alone was undertaken. Eighty-five aneurysms were coiled; 62% with Hydrocoil alone, 38% in combination with BPC. At six-month follow-up, overall 50% were completely occluded, 39.5% had a neck remnant and 10.5% had a residual aneurysm. Complete occlusion was identified in 39% in the Hydrocoil and BPC group compared to 56% in the Hydrocoil alone group. In 56/76 (74%) cases analysed, Hydrocoil loop successfully bridged the neck of the aneurysm in which 38/76 (68%) of these were completely occluded at six-month follow-up. Thirteen procedure-related complications occurred. Aneurysms treated with Hydrocoil alone resulted in fewer recurrences compared with a combination of Hydrocoil and BPC. These data suggest that the technique of positioning Hydrocoil at the neck of the aneurysm increases the probability of complete occlusion and is therefore a strong predictor of aneurysm occlusion. In our experience, this technique did not demonstrate an increased risk of intra-procedural rupture or thrombo-embolic complications compared to conventional embolization with BPC. PMID:24556298

  5. Complete occlusion of the right middle cerebral artery associated with Mycoplasma pneumoniae pneumonia

    PubMed Central

    Kang, Ben; Kim, Dong Hyun; Hong, Young Jin; Son, Byong Kwan; Lim, Myung Kwan; Choe, Yon Ho

    2016-01-01

    We report a case of a 5-year-old girl who developed left hemiparesis and left facial palsy, 6 days after the initiation of fever and respiratory symptoms due to pneumonia. Chest radiography, conducted upon admission, showed pneumonic infiltration and pleural effusion in the left lung field. Brain magnetic resonance imaging showed acute ischemic infarction in the right middle cerebral artery territory. Brain magnetic resonance angiography and transfemoral cerebral angiography revealed complete occlusion of the right middle cerebral artery. Mycoplasma pneumoniae infection was identified by a 4-fold increase in IgG antibodies to M. pneumoniae between acute and convalescent sera by enzyme-linked immunosorbent assay. Fibrinogen and D-dimer levels were elevated, while laboratory exams in order to identify other predisposing factors of pediatric stroke were all negative. This is the first reported pediatric case in English literature of a M. pneumoniae-associated cerebral infarction involving complete occlusion of the right middle cerebral artery. PMID:27186223

  6. Complete occlusion of the proximal subclavian artery post-CABG: Presentation and treatment

    PubMed Central

    Sadek, Mouhannad M; Ravindran, Aravindhan; Marcuzzi, Daniel W; Chisholm, Robert J

    2008-01-01

    Atherosclerotic disease of the proximal left subclavian artery is an uncommon cause of angina in the post-coronary artery bypass graft patient, and is termed coronary-subclavian steal syndrome. Typical manifestations include cardiac symptoms of angina and noncardiac symptoms of lightheadedness, left arm numbness or weakness, and a difference in blood pressure of more than 20 mmHg between both arms. A case of complete proximal occlusion of the subclavian artery is reported. The clinical picture, investigations and treatment are described. Historical treatments of occlusive disease include surgical bypass graft and, more recently, percutaneous transluminal angioplasty. The patient underwent percutaneous transluminal angioplasty with stenting by a retrograde approach, with an excellent short-term response, but ultimately required a carotid subclavian bypass due to restenosis. PMID:18612504

  7. Intraoperative bleeding control during cesarean delivery of complete placenta previa with transient occlusion of uterine arteries

    PubMed Central

    Kim, Ju Hyun; Joung, Eun-Ju; Lee, Soo-Jung; Kwack, Jae Young

    2015-01-01

    There are few methods to control heavy intra-operative bleeding during cesarean delivery of placenta previa. Transient occlusion of uterine arteries (TOUA) during operation has previously been reported as a quick and safe method to control intra-operative uterine bleeding. We reported 2 cases of cesarean delivery with complete placenta previa in which TOUA was performed to safely reduce intra-operative complication, especially heavy intra-operative bleeding. In the 2 cases, cesarean deliveries were safe and without any complications under the TOUA method. TOUA can be a good method to control heavy intra-operative bleeding during cesarean delivery of complete placenta previa with risk of heavy bleeding. PMID:26623419

  8. Complete Occlusal Rehabilitation of Patient with Radiation Caries – A Case Report

    PubMed Central

    Gandhewar, Mahesh Arvind

    2014-01-01

    One of the most distressing and dramatic causes of xerostomia is radiotherapy for the cure of maxillofacial and neck carcinomas. Patient with radiotherapy induced xerostomia presents with challenges in prosthodontic management and in unique radiation caries control. This clinical report illustrates step by step execution of complex treatment planning that lead to successful outcome in 34-year-old man, who had been treated with Radical Neck Dissection (RND) and therapeutic radiotherapy for squamous cell carcinoma of tongue and due to radiation caries, was presented with chief complaint of difficulty in mastication. Rehabilitation was carried out with metal-ceramic fixed restorations and cast removable prostheses after extensive endodontic intervention. This article also discusses the maintenance strategies for radiation caries patient requiring complete occlusal reconstruction, who certainly presents with special needs in post-treatment management. PMID:25386544

  9. Nucleoid occlusion protein Noc recruits DNA to the bacterial cell membrane

    PubMed Central

    Adams, David William; Wu, Ling Juan; Errington, Jeff

    2015-01-01

    To proliferate efficiently, cells must co-ordinate division with chromosome segregation. In Bacillus subtilis, the nucleoid occlusion protein Noc binds to specific DNA sequences (NBSs) scattered around the chromosome and helps to protect genomic integrity by coupling the initiation of division to the progression of chromosome replication and segregation. However, how it inhibits division has remained unclear. Here, we demonstrate that Noc associates with the cell membrane via an N-terminal amphipathic helix, which is necessary for function. Importantly, the membrane-binding affinity of this helix is weak and requires the assembly of nucleoprotein complexes, thus establishing a mechanism for DNA-dependent activation of Noc. Furthermore, division inhibition by Noc requires recruitment of NBS DNA to the cell membrane and is dependent on its ability to bind DNA and membrane simultaneously. Indeed, Noc production in a heterologous system is sufficient for recruitment of chromosomal DNA to the membrane. Our results suggest a simple model in which the formation of large membrane-associated nucleoprotein complexes physically occludes assembly of the division machinery. PMID:25568309

  10. A Molecularly Complete Planar Bacterial Outer Membrane Platform.

    PubMed

    Hsia, Chih-Yun; Chen, Linxiao; Singh, Rohit R; DeLisa, Matthew P; Daniel, Susan

    2016-01-01

    The bacterial outer membrane (OM) is a barrier containing membrane proteins and liposaccharides that fulfill crucial functions for Gram-negative bacteria. With the advent of drug-resistant bacteria, it is necessary to understand the functional role of this membrane and its constituents to enable novel drug designs. Here we report a simple method to form an OM-like supported bilayer (OM-SB), which incorporates native lipids and membrane proteins of gram-negative bacteria from outer membrane vesicles (OMVs). We characterize the formation of OM-SBs using quartz crystal microbalance with dissipation (QCM-D) and fluorescence microscopy. We show that the orientation of proteins in the OM-SB matches the native bacterial membrane, preserving the characteristic asymmetry of these membranes. As a demonstration of the utility of the OM-SB platform, we quantitatively measure antibiotic interactions between OM-SBs and polymyxin B, a cationic peptide used to treat Gram-negative infections. This data enriches understanding of the antibacterial mechanism of polymyxin B, including disruption kinetics and changes in membrane mechanical properties. Combining OM-SBs with microfluidics will enable higher throughput screening of antibiotics. With a broader view, we envision that a molecularly complete membrane-scaffold could be useful for cell-free applications employing engineered membrane proteins in bacterial membranes for myriad technological purposes. PMID:27600663

  11. A Molecularly Complete Planar Bacterial Outer Membrane Platform

    PubMed Central

    Hsia, Chih-Yun; Chen, Linxiao; Singh, Rohit R.; DeLisa, Matthew P.; Daniel, Susan

    2016-01-01

    The bacterial outer membrane (OM) is a barrier containing membrane proteins and liposaccharides that fulfill crucial functions for Gram-negative bacteria. With the advent of drug-resistant bacteria, it is necessary to understand the functional role of this membrane and its constituents to enable novel drug designs. Here we report a simple method to form an OM-like supported bilayer (OM-SB), which incorporates native lipids and membrane proteins of gram-negative bacteria from outer membrane vesicles (OMVs). We characterize the formation of OM-SBs using quartz crystal microbalance with dissipation (QCM-D) and fluorescence microscopy. We show that the orientation of proteins in the OM-SB matches the native bacterial membrane, preserving the characteristic asymmetry of these membranes. As a demonstration of the utility of the OM-SB platform, we quantitatively measure antibiotic interactions between OM-SBs and polymyxin B, a cationic peptide used to treat Gram-negative infections. This data enriches understanding of the antibacterial mechanism of polymyxin B, including disruption kinetics and changes in membrane mechanical properties. Combining OM-SBs with microfluidics will enable higher throughput screening of antibiotics. With a broader view, we envision that a molecularly complete membrane-scaffold could be useful for cell-free applications employing engineered membrane proteins in bacterial membranes for myriad technological purposes. PMID:27600663

  12. Mitigation of Effects of Occlusion on Object Recognition with Deep Neural Networks through Low-Level Image Completion.

    PubMed

    Chandler, Benjamin; Mingolla, Ennio

    2016-01-01

    Heavily occluded objects are more difficult for classification algorithms to identify correctly than unoccluded objects. This effect is rare and thus hard to measure with datasets like ImageNet and PASCAL VOC, however, owing to biases in human-generated image pose selection. We introduce a dataset that emphasizes occlusion and additions to a standard convolutional neural network aimed at increasing invariance to occlusion. An unmodified convolutional neural network trained and tested on the new dataset rapidly degrades to chance-level accuracy as occlusion increases. Training with occluded data slows this decline but still yields poor performance with high occlusion. Integrating novel preprocessing stages to segment the input and inpaint occlusions is an effective mitigation. A convolutional network so modified is nearly as effective with more than 81% of pixels occluded as it is with no occlusion. Such a network is also more accurate on unoccluded images than an otherwise identical network that has been trained with only unoccluded images. These results depend on successful segmentation. The occlusions in our dataset are deliberately easy to segment from the figure and background. Achieving similar results on a more challenging dataset would require finding a method to split figure, background, and occluding pixels in the input. PMID:27340396

  13. Mitigation of Effects of Occlusion on Object Recognition with Deep Neural Networks through Low-Level Image Completion

    PubMed Central

    Mingolla, Ennio

    2016-01-01

    Heavily occluded objects are more difficult for classification algorithms to identify correctly than unoccluded objects. This effect is rare and thus hard to measure with datasets like ImageNet and PASCAL VOC, however, owing to biases in human-generated image pose selection. We introduce a dataset that emphasizes occlusion and additions to a standard convolutional neural network aimed at increasing invariance to occlusion. An unmodified convolutional neural network trained and tested on the new dataset rapidly degrades to chance-level accuracy as occlusion increases. Training with occluded data slows this decline but still yields poor performance with high occlusion. Integrating novel preprocessing stages to segment the input and inpaint occlusions is an effective mitigation. A convolutional network so modified is nearly as effective with more than 81% of pixels occluded as it is with no occlusion. Such a network is also more accurate on unoccluded images than an otherwise identical network that has been trained with only unoccluded images. These results depend on successful segmentation. The occlusions in our dataset are deliberately easy to segment from the figure and background. Achieving similar results on a more challenging dataset would require finding a method to split figure, background, and occluding pixels in the input. PMID:27340396

  14. The influence of immediate complete anterior guidance development technique on subjective symptoms in Myofascial pain patients: Verified using digital analysis of occlusion (Tek-scan) for analysing occlusion: A 3 years clinical observation

    PubMed Central

    Thumati, Prafulla

    2015-01-01

    Objectives: The purpose of this study is to evaluate the effect of occlusal equilibration using immediate complete anterior guidance development (ICAGD) technique by Kerstein and Farrell on the subjective symptoms of myofascial pain. This technique is the most advanced verifiable and measurable way of digitally analyzing the occlusion using T-scan technology. The primary objective is to reduce the anterior disclusion time to <0.4 s and the secondary objective is to reduce the signs and symptoms of myofascial pain. Materials and Methods: This study is to assess the reducing effects of subjective symptoms of 100 patients diagnosed as myofascial pain patients treated by ICAGD technique as described by Kerstein and Farrell. The common complaints of the patients were a pain in the masseter and temporal muscles, jaw tiredness in the mornings, night bruxing and difficulty in chewing. In this technique occlusal equilibration involves removal of posterior interferences and establish anterior guidance. The patients were treated over three visits 1-week apart and followed for 3 years with an interval of 3 months for the subsequent visits. A visual analog ordinal scale is used to rate the symptoms. The symptoms reduction occurred for all the patients after the first correction in about 5–10 days. In about a period of 3 years review, no recurrence was seen of the chronic myofascial symptoms. Results: In spite of the chronic nature of the patient's symptoms, symptom reduction occurred in a week's time. This was assessed by the results of the ordinal scale values. This agrees with the studies of Kerstein and Farrell. Conclusion: Equilibration of occlusion using digital analysis by T-scan in which force is quantified against time, should be done to establish free functional movements without any interference; otherwise the disturbances in the excursive movements may lead to muscle dysfunction at later years. PMID:26929516

  15. Colicin Occlusion of OmpF and TolC Channels: Outer Membrane Translocons for Colicin Import

    PubMed Central

    Zakharov, Stanislav D.; Eroukova, Veronika Y.; Rokitskaya, Tatyana I.; Zhalnina, Mariya V.; Sharma, Onkar; Loll, Patrick J.; Zgurskaya, Helen I.; Antonenko, Yuri N.; Cramer, William A.

    2004-01-01

    The interaction of colicins with target cells is a paradigm for protein import. To enter cells, bactericidal colicins parasitize Escherichia coli outer membrane receptors whose physiological purpose is the import of essential metabolites. Colicins E1 and E3 initially bind to the BtuB receptor, whose β-barrel pore is occluded by an N-terminal globular “plug”. The x-ray structure of a complex of BtuB with the coiled-coil BtuB-binding domain of colicin E3 did not reveal displacement of the BtuB plug that would allow passage of the colicin (Kurisu, G., S. D. Zakharov, M. V. Zhalnina, S. Bano, V. Y. Eroukova, T. I. Rokitskaya, Y. N. Antonenko, M. C. Wiener, and W. A. Cramer. 2003. Nat. Struct. Biol. 10:948–954). This correlates with the inability of BtuB to form ion channels in planar bilayers, shown in this work, suggesting that an additional outer membrane protein(s) is required for colicin import across the outer membrane. The identity and interaction properties of this OMP were analyzed in planar bilayer experiments.OmpF and TolC channels in planar bilayers were occluded by colicins E3 and E1, respectively, from the trans-side of the membrane. Occlusion was dependent upon a cis-negative transmembrane potential. A positive potential reversibly opened OmpF and TolC channels. Colicin N, which uses only OmpF for entry, occludes OmpF in planar bilayers with the same orientation constraints as colicins E1 and E3. The OmpF recognition sites of colicins E3 and N, and the TolC recognition site of colicin E1, were found to reside in the N-terminal translocation domains. These data are considered in the context of a two-receptor translocon model for colicin entry into cells. PMID:15465872

  16. Occlusal stability.

    PubMed

    Wiens, Jonathan P; Priebe, Jennifer W

    2014-01-01

    Occlusion is the foundation for clinical success in fixed, removable, and implant prosthodontic treatment. Understanding those principles is critical when restoring a patient's occlusion. Many philosophies, devices, and theories of occlusion have evolved based on anecdotal clinical observations and applied geometric perceptions. The literature has reported these classic and contemporary occlusal concepts. As evidence-based dentistry emerged, it championed scrutiny of previously held beliefs, resulting in the abandonment of many pragmatic, yet beneficial occlusal procedures. The impetus toward scientific discovery, whereby factual information might be universally applied in dental education and clinical practice, has renewed interest in occlusal studies. PMID:24286644

  17. Natural channel protein inserts and functions in a completely artificial, solid-supported bilayer membrane

    PubMed Central

    Zhang, Xiaoyan; Fu, Wangyang; Palivan, Cornelia G.; Meier, Wolfgang

    2013-01-01

    Reconstitution of membrane proteins in artificial membrane systems creates a platform for exploring their potential for pharmacological or biotechnological applications. Previously, we demonstrated amphiphilic block copolymers as promising building blocks for artificial membranes with long-term stability and tailorable structural parameters. However, the insertion of membrane proteins has not previously been realized in a large-area, stable, and solid-supported artificial membrane. Here, we show the first, preliminary model of a channel membrane protein that is functionally incorporated in a completely artificial polymer, tethered, solid-supported bilayer membrane (TSSBM). Unprecedented ionic transport characteristics that differ from previous results on protein insertion into planar, free-standing membranes, are identified. Our findings mark a change in understanding protein insertion and ion flow within natural channel proteins when inserted in an artificial TSSBM, thus holding great potential for numerous applications such as drug screening, trace analyzing, and biosensing. PMID:23846807

  18. Juxtarenal aortic occlusion.

    PubMed Central

    Tapper, S S; Jenkins, J M; Edwards, W H; Mulherin, J L; Martin, R S; Edwards, W H

    1992-01-01

    The authors' experience with 113 aortic occlusions in 103 patients during a 26-year period (1965 to 1991) is reviewed. The authors found three distinct patterns of presentation: group I (n = 26) presented with acute aortic occlusion, group II (n = 66) presented with chronic aortic occlusion, and group III (n = 21) presented with complete occlusion of an aortic graft. Perioperative mortality rates were 31%, 9%, and 4.7% for each respective group and achieved statistical significance when comparing group I with group II (p = 0.009) and group I with group III (p = 0.015). Group I presented with profound metabolic insults due to acute ischemia and fared poorly. Group II presented with chronic claudication and did well long-term. Group III presented with acute ischemia but did well because of established collateral circulation. The treatment and expected outcome of aortic occlusion depends on the cause. PMID:1616381

  19. Pars plana vitrectomy combined with internal limiting membrane peeling for recurrent macular edema due to branch retinal vein occlusion after antivascular endothelial growth factor treatments

    PubMed Central

    Shirakata, Yukari; Fukuda, Kouki; Fujita, Tomoyoshi; Nakano, Yuki; Nomoto, Hiroyuki; Yamaji, Hidetaka; Shiraga, Fumio; Tsujikawa, Akitaka

    2016-01-01

    Purpose To evaluate the anatomic and functional outcomes of pars plana vitrectomy combined with internal limiting membrane peeling for recurrent macular edema (ME) due to branch retinal vein occlusion (BRVO) after intravitreal injections of antivascular endothelial growth factor (anti-VEGF) agents. Methods Twenty-four eyes of 24 patients with treatment-naive ME from BRVO were treated with intravitreal injections of anti-VEGF agents. Recurred ME was treated with pars plana vitrectomy combined with internal limiting membrane peeling. Results After the surgery, ME was significantly reduced at 1 month (P=0.031) and the reduction increased with time (P=0.007 at the final visit). With the reduction in ME, treated eyes showed a slow improvement in visual acuity (VA). At the final visit, improvement in VA was statistically significant compared with baseline (P=0.048). The initial presence of cystoid spaces, serous retinal detachment, or subretinal hemorrhage under the fovea, as well as retinal perfusion status, showed no association with VA improvement. However, the presence of epiretinal membrane showed a significant association with the visual recovery. Although eyes without epiretinal membrane showed visual improvement (−0.10±0.32 in logarithm of the minimum angle of resolution [logMAR]), eyes with epiretinal membrane showed greater visual improvement (−0.38±0.12 in logMAR, P=0.012). Conclusion For recurrent ME due to BRVO after anti-VEGF treatment, particularly when accompanied by epiretinal membrane, pars plana vitrectomy combined with internal limiting membrane peeling might be a possible treatment option. PMID:26917950

  20. An alternative treatment of occlusal wear: cast metal occlusal surface.

    PubMed

    Kumar, Sandeep; Arora, Aman; Yadav, Reena

    2012-01-01

    Acrylic resin denture teeth often exhibit rapid occlusal wear, which may lead to decrease in the chewing efficiency, loss of vertical dimension of occlusion, denture instability, temporomandibular joint disturbances, etc. There are various treatment options available like, use of highly cross linked acrylic teeth, amalgam or metal inserts on occlusal surface, use of composite, gold or metal occlusal surface, etc. Several articles have described methods to construct gold and metal occlusal surfaces, however, these methods are time-consuming, expensive and requires many cumbersome steps. These methods also requires the patient to be without the prosthesis for the time during which the laboratory procedures are performed. This article presents a quick, simple and relatively inexpensive procedure for construction of metal occlusal surfaces on complete dentures. PMID:22945724

  1. Complete dissociation of the HIV-1 gp41 ectodomain and membrane proximal regions upon phospholipid binding

    PubMed Central

    Roche, Julien; Louis, John M.; Aniana, Annie; Ghirlando, Rodolfo; Bax, Ad

    2015-01-01

    The envelope glycoprotein gp41 mediates the process of membrane fusion that enables entry of the HIV-1 virus into the host cell. Strong lipid affinity of the ectodomain suggests that its heptad repeat regions play an active role in destabilizing membranes by directly binding to the lipid bilayers and thereby lowering the free-energy barrier for membrane fusion. In such a model, immediately following the shedding of gp120, the N-heptad and C-heptad helices dissociate and melt into the host cell and viral membranes, respectively, pulling the destabilized membranes into juxtaposition, ready for fusion. Post-fusion, reaching the final 6-helix bundle (6HB) conformation then involves competition between intermolecular interactions needed for formation of the symmetric 6HB trimer and the membrane affinity of gp41's ectodomain, including its membrane-proximal regions. Our solution NMR study of the structural and dynamic properties of three constructs containing the ectodomain of gp41 with and without its membrane-proximal regions suggests that these segments do not form inter-helical interactions until the very late steps of the fusion process. Interactions between the polar termini of the heptad regions, which are not associating with the lipid surface, therefore may constitute the main driving force initiating formation of the final post-fusion states. The absence of significant intermolecular ectodomain interactions in the presence of dodecyl phosphocholine highlights the importance of trimerization of gp41’s transmembrane helix to prevent complete dissociation of the trimer during the course of fusion. PMID:25631354

  2. A live birth after spontaneous complete chorioamniotic membrane separation associated with uterine scar

    PubMed Central

    Joung, Eun Joo; You, Seul Ki; Ahn, Jun Woo; Yun, Nae Ri; Hwang, Sung Ook

    2016-01-01

    Spontaneous complete chorioamniotic membrane separation (CMS) without invasive fetal procedure is extremely rare and associated with adverse perinatal outcomes. A woman with complete CMS which was detected at the 21 weeks' gestation. She did not take any fetal invasive procedures before the diagnosis. At 27 weeks' gestation, an emergency Caesarean section was performed because of fetal distress. The defect of the uterine muscle was detected on the fundus. The baby has grown well without any morbidity. This is the first reported case of complete CMS relative to uterine scar. And we suggest that the pregnancy can be maintained successfully if there is no fetal abnormality when complete CMS is detected on ultrasound. PMID:27004206

  3. [Complete occlusion of an endotrachealtube in the course of long-lasting anaesthesia. A hazard of reinforced latex tubes (author's transl)].

    PubMed

    Roth, H G

    1978-01-01

    A case of sudden occlusion of a reinforced latex endotracheal tube is reported. The event took place four hours and twenty minutes after induction of anaesthesia. Reintubation during operation became necessary under difficult circumstances. The causes of such incidents, and appropriate preventive measures are discussed. PMID:637288

  4. Simultaneous transfemoral transcatheter mitral and tricuspid valve edge-to-edge repair (using MitraClip system) completed by atrial septal defect occlusion in a surgically inoperable patient. First-in-human report

    PubMed Central

    Franz, Norbert; Ritter, Frank; Hofmann, Steffen; Stabel-Mahassine, Chourok; Warnecke, Henning; Thale, Joachim

    2015-01-01

    Transcatheter transfemoral mitral valve repair using the MitraClip system (Abbott Vascular, USA) is used in high-risk or inoperable patients with severe mitral regurgitation. We report the first-in-human simultaneous transfemoral clipping of the mitral and tricuspid valve completed by occlusion of an atrial septal defect (ASD). The procedure was performed in an 84-year-old patient in October 2015. After effective reduction of mitral and tricuspid regurgitations using the MitraClip system a PFO Occluder (St. Jude Medical, USA) was implanted. Transfemoral simultaneous mitral and tricuspid valve repair using the MitraClip system with ASD occlusion seems to be an effective therapy for high-risk or inoperable patients. PMID:26855642

  5. Simultaneous transfemoral transcatheter mitral and tricuspid valve edge-to-edge repair (using MitraClip system) completed by atrial septal defect occlusion in a surgically inoperable patient. First-in-human report.

    PubMed

    Kowalski, Marek; Franz, Norbert; Ritter, Frank; Hofmann, Steffen; Stabel-Mahassine, Chourok; Warnecke, Henning; Thale, Joachim

    2015-12-01

    Transcatheter transfemoral mitral valve repair using the MitraClip system (Abbott Vascular, USA) is used in high-risk or inoperable patients with severe mitral regurgitation. We report the first-in-human simultaneous transfemoral clipping of the mitral and tricuspid valve completed by occlusion of an atrial septal defect (ASD). The procedure was performed in an 84-year-old patient in October 2015. After effective reduction of mitral and tricuspid regurgitations using the MitraClip system a PFO Occluder (St. Jude Medical, USA) was implanted. Transfemoral simultaneous mitral and tricuspid valve repair using the MitraClip system with ASD occlusion seems to be an effective therapy for high-risk or inoperable patients. PMID:26855642

  6. Structure of a Complete ATP Synthase Dimer Reveals the Molecular Basis of Inner Mitochondrial Membrane Morphology.

    PubMed

    Hahn, Alexander; Parey, Kristian; Bublitz, Maike; Mills, Deryck J; Zickermann, Volker; Vonck, Janet; Kühlbrandt, Werner; Meier, Thomas

    2016-08-01

    We determined the structure of a complete, dimeric F1Fo-ATP synthase from yeast Yarrowia lipolytica mitochondria by a combination of cryo-EM and X-ray crystallography. The final structure resolves 58 of the 60 dimer subunits. Horizontal helices of subunit a in Fo wrap around the c-ring rotor, and a total of six vertical helices assigned to subunits a, b, f, i, and 8 span the membrane. Subunit 8 (A6L in human) is an evolutionary derivative of the bacterial b subunit. On the lumenal membrane surface, subunit f establishes direct contact between the two monomers. Comparison with a cryo-EM map of the F1Fo monomer identifies subunits e and g at the lateral dimer interface. They do not form dimer contacts but enable dimer formation by inducing a strong membrane curvature of ∼100°. Our structure explains the structural basis of cristae formation in mitochondria, a landmark signature of eukaryotic cell morphology. PMID:27373333

  7. Complete anal membrane in a female: a rare malformation and indication for prone cross-table lateral radiograph.

    PubMed

    England, Richard J; Murthi, Govind V

    2013-04-01

    Magnetic resonance imaging (MRI) of a 27 week gestation female fetus suggested an abnormal rectum. Subsequent examination of the term newborn confirmed an imperforate anus present in the normal position. No meconium was seen on the perineum by 18 hours. A prone cross-table lateral radiograph confirmed that rectal gas was present 3 mm beneath the membrane leading to the diagnosis of complete anal membrane, and an anoplasty rather than a colostomy was performed. PMID:23583151

  8. A self-sustained, complete and miniaturized methanol fuel processor for proton exchange membrane fuel cell

    NASA Astrophysics Data System (ADS)

    Yang, Mei; Jiao, Fengjun; Li, Shulian; Li, Hengqiang; Chen, Guangwen

    2015-08-01

    A self-sustained, complete and miniaturized methanol fuel processor has been developed based on modular integration and microreactor technology. The fuel processor is comprised of one methanol oxidative reformer, one methanol combustor and one two-stage CO preferential oxidation unit. Microchannel heat exchanger is employed to recover heat from hot stream, miniaturize system size and thus achieve high energy utilization efficiency. By optimized thermal management and proper operation parameter control, the fuel processor can start up in 10 min at room temperature without external heating. A self-sustained state is achieved with H2 production rate of 0.99 Nm3 h-1 and extremely low CO content below 25 ppm. This amount of H2 is sufficient to supply a 1 kWe proton exchange membrane fuel cell. The corresponding thermal efficiency of whole processor is higher than 86%. The size and weight of the assembled reactors integrated with microchannel heat exchangers are 1.4 L and 5.3 kg, respectively, demonstrating a very compact construction of the fuel processor.

  9. Endoluminal occlusion devices: technology update

    PubMed Central

    Zander, Tobias; Medina, Samantha; Montes, Guillermo; Nuñez-Atahualpa, Lourdes; Valdes, Michel; Maynar, Manuel

    2014-01-01

    Endoluminal occlusion has been performed since the early beginning of interventional radiology. Over recent decades, major technological advances have improved the techniques used and different devices have been developed for changing conditions. Most of these occlusion devices have been implemented in the vascular territory. Early embolization materials included glass particles, hot contrast, paraffin, fibrin, and tissue fragments such as muscle fibers and blood clots; today, occlusion materials include metallic devices, particles, and liquid materials, which can be indicated for proximal or distal occlusion, high-flow and low-flow situations, and in large-caliber and small-caliber vessels, based on need. Technological progress has led to a decreased size of delivery catheters, and an increase in safety due to release systems that permit the withdrawing and replacement of embolization material. Furthermore, bioactive embolization materials have been developed to increase the efficacy of embolization or the biological effect of medication. Finally, materials have been modified for changing indications. Intravascular stents were initially developed to keep an artery open; however, by adding a covering membrane, these stents can be used to occlude the wall of a vessel or other endoluminal structures. This article gives an overview of the devices most utilized for occlusion of endoluminal structures, as well as their major purpose in the endovascular territory. PMID:25489252

  10. Branch retinal vein occlusion.

    PubMed

    Hamid, Sadaf; Mirza, Sajid Ali; Shokh, Ishrat

    2008-01-01

    Retinal vein occlusions (RVO) are the second commonest sight threatening vascular disorder. Branch retinal vein occlusion (BRVO) and central retinal vein occlusion (CRVO) are the two basic types of vein occlusion. Branch retinal vein occlusion is three times more common than central retinal vein occlusion and- second only to diabetic retinopathy as the most common retinal vascular cause of visual loss. The origin of branch retinal vein occlusion undoubtedly includes both systemic factors such as hypertension and local anatomic factors such as arteriovenous crossings. Branch retinal vein occlusion causes a painless decrease in vision, resulting in misty or distorted vision. Current treatment options don't address the underlying aetiology of branch retinal vein occlusion. Instead they focus on treating sequelae of the occluded venous branch, such as macular oedema, vitreous haemorrhage and traction retinal detachment from neovascularization. Evidences suggest that the pathogenesis of various types of retinal vein occlusion, like many other ocular vascular occlusive disorders, is a multifactorial process and there is no single magic bullet that causes retinal vein occlusion. A comprehensive management of patients with retinal vascular occlusions is necessary to correct associated diseases or predisposing abnormalities that could lead to local recurrences or systemic event. Along with a review of the literature, a practical approach for the management of retinal vascular occlusions is required, which requires collaboration between the ophthalmologist and other physicians: general practitioner, cardiologist, internist etc. as appropriate according to each case. PMID:19385476

  11. Concepts of occlusion in prosthodontics: A literature review, part I

    PubMed Central

    Rangarajan, V.; Gajapathi, B.; Yogesh, P. B.; Ibrahim, M. Mohamed; Kumar, R. Ganesh; Karthik, Prasanna

    2015-01-01

    Occlusion and its relationship to the function of the stomatognathic system have been widely studied in dentistry since many decades. This series of articles describe about occlusion in the complete denture, fixed partial denture, and implants. Part I and II of this articles series describe concepts and philosophies of occlusion in complete denture. So far, available research has not concluded a superior tooth form or occlusal scheme to satisfy the requirements of completely edentulous patients with respect to comfort, mastication, phonetics, and esthetics. Since then, several balanced and nonbalanced articulation concepts were proposed in the literature. A balanced articulation appears to be most appropriate because of tooth contacts observed during nonfunctional activities of patients. This article discusses about evolution of different concepts of occlusion and occlusal schemes in complete denture occlusion. PMID:26929513

  12. Using zirconia-based prosthesis in a complete-mouth reconstruction treatment for worn dentition with the altered vertical dimension of occlusion.

    PubMed

    Nam, Jung; Tokutomi, Hiro

    2015-02-01

    This clinical report describes the complete mouth reconstruction of a patient with a worn dentition. Computer-aided design and computer-aided manufacturing processed porcelain fused-to-zirconia prostheses were used to achieve good esthetics, function, and biomechanics. PMID:25438749

  13. Acute arterial occlusion - kidney

    MedlinePlus

    ... arterial thrombosis; Renal artery embolism; Acute renal artery occlusion; Embolism - renal artery ... often result in permanent kidney failure. Acute arterial occlusion of the renal artery can occur after injury ...

  14. Inhibition of HIV-1 endocytosis allows lipid mixing at the plasma membrane, but not complete fusion

    PubMed Central

    2011-01-01

    Background We recently provided evidence that HIV-1 enters HeLa-derived TZM-bl and lymphoid CEMss cells by fusing with endosomes, whereas its fusion with the plasma membrane does not proceed beyond the lipid mixing step. The mechanism of restriction of HIV-1 fusion at the cell surface and/or the factors that aid the virus entry from endosomes remain unclear. Results We examined HIV-1 fusion with a panel of target cells lines and with primary CD4+ T cells. Kinetic measurements of fusion combined with time-resolved imaging of single viruses further reinforced the notion that HIV-1 enters the cells via endocytosis and fusion with endosomes. Furthermore, we attempted to deliberately redirect virus fusion to the plasma membrane, using two experimental strategies. First, the fusion reaction was synchronized by pre-incubating the viruses with cells at reduced temperature to allow CD4 and coreceptors engagement, but not the virus uptake or fusion. Subsequent shift to a physiological temperature triggered accelerated virus uptake followed by entry from endosomes, but did not permit fusion at the cell surface. Second, blocking HIV-1 endocytosis by a small-molecule dynamin inhibitor, dynasore, resulted in transfer of viral lipids to the plasma membrane without any detectable release of the viral content into the cytosol. We also found that a higher concentration of dynasore is required to block the HIV-endosome fusion compared to virus internalization. Conclusions Our results further support the notion that HIV-1 enters disparate cell types through fusion with endosomes. The block of HIV-1 fusion with the plasma membrane at a post-lipid mixing stage shows that this membrane is not conducive to fusion pore formation and/or enlargement. The ability of dynasore to interfere with the virus-endosome fusion suggests that dynamin could be involved in two distinct steps of HIV-1 entry - endocytosis and fusion within intracellular compartments. PMID:22145853

  15. Follicular occlusion tetrad.

    PubMed

    Vasanth, Vani; Chandrashekar, Byalakere Shivanna

    2014-10-01

    Follicular occlusion tetrad is a symptom complex consisting of four conditions having a similar pathophysiology. It includes Hidradenitis suppurativa, acne conglobata, dissecting cellulitis of the scalp and pilonidal sinus. The exact pathogenesis of this group of disease is unknown but evidence suggests that they share the same pathological process initiated by follicular occlusion in apocrine gland bearing areas. Though each of these conditions is commonly encountered singly, follicular occlusion tetrad as a symptom complex has been rarely reported in the literature. PMID:25396138

  16. Follicular occlusion tetrad

    PubMed Central

    Vasanth, Vani; Chandrashekar, Byalakere Shivanna

    2014-01-01

    Follicular occlusion tetrad is a symptom complex consisting of four conditions having a similar pathophysiology. It includes Hidradenitis suppurativa, acne conglobata, dissecting cellulitis of the scalp and pilonidal sinus. The exact pathogenesis of this group of disease is unknown but evidence suggests that they share the same pathological process initiated by follicular occlusion in apocrine gland bearing areas. Though each of these conditions is commonly encountered singly, follicular occlusion tetrad as a symptom complex has been rarely reported in the literature. PMID:25396138

  17. Effects of Deletion and Overexpression of the Autographa californica Nuclear Polyhedrosis Virus FP25K Gene on Synthesis of Two Occlusion-Derived Virus Envelope Proteins and Their Transport into Virus-Induced Intranuclear Membranes

    PubMed Central

    Rosas-Acosta, Germán; Braunagel, Sharon C.; Summers, Max D.

    2001-01-01

    Partial deletions within Autographa californica open reading frame 61 (FP25K) alter the expression and accumulation profile of several viral proteins and the transport of occlusion-derived virus (ODV)-E66 to intranuclear membranes during infection (S. C. Braunagel et al., J. Virol. 73:8559–8570, 1999). Here we show the effects of a full deletion and overexpression of FP25K on the transport and expression of two ODV envelope proteins, ODV-E66 (E66) and ODV-E25 (E25). Deletion and overexpression of FP25K substantially altered the levels of expression of E66 during infection. Compared with cells infected with wild-type (wt) virus, the levels of E66 were reduced fivefold in cells infected with a viral mutant lacking FP25K (ΔFP25K) and were slightly increased in cells infected with a viral mutant overexpressing FP25K (FP25Kpolh). In contrast, no significant changes were observed in the levels of E25 among wt-, ΔFP25K-, and FP25Kpolh-infected cells. The changes observed in the levels of E66 among the different viral mutants were not accompanied by changes in either the time of synthesis, membrane association, protein turnover, or steady-state transcript abundance. Deletion of FP25K also substantially altered the transport and localization of E66 during infection. In cells infected with the ΔFP25K mutant virus, E66 accumulated in localized regions at the nuclear periphery and the outer nuclear membrane and did not traffic to intranuclear membranes. In contrast, in cells infected with the FP25Kpolh mutant virus E66 trafficked to intranuclear membranes. For comparison, E25 was normally transported to intranuclear membranes in both ΔFP25K- and FP25Kpolh-infected cells. Altogether these studies suggest that FP25K affects the synthesis of E66 at a posttranscriptional level, probably by altering the translation of E66; additionally, the block in transport of E66 at the nuclear envelope in ΔFP25K-infected cells suggests that the pathway of E66 trafficking to the inner

  18. Preparation and Characterization of Chitosan Thin Films on Mixed-Matrix Membranes for Complete Removal of Chromium

    PubMed Central

    Nayak, Vignesh; Jyothi, Mannekote Shivanna; Balakrishna, R Geetha; Padaki, Mahesh; Ismail, Ahmad Fauzi

    2015-01-01

    Herein we present a new approach for the complete removal of CrVI species, through reduction of CrVI to CrIII, followed by adsorption of CrIII. Reduction of chromium from water is an important challenge, as CrIV is one of the most toxic substances emitted from industrial processes. Chitosan (CS) thin films were developed on plain polysulfone (PSf) and PSf/TiO2 membrane substrates by a temperature-induced technique using polyvinyl alcohol as a binder. Structure property elucidation was carried out by X-ray diffraction, microscopy, spectroscopy, contact angle measurement, and water uptake studies. The increase in hydrophilicity followed the order: PSf < PSf/TiO2 < PSf/TiO2/CS membranes. Use of this thin-film composite membrane for chromium removal was investigated with regards to the effects of light and pH. The observations reveal 100 % reduction of CrVI to CrIII through electrons and protons donated from OH and NH2 groups of the CS layer; the reduced CrIII species are adsorbed onto the CS layer via complexation to give chromium-free water. PMID:26246989

  19. Preparation and Characterization of Chitosan Thin Films on Mixed-Matrix Membranes for Complete Removal of Chromium.

    PubMed

    Nayak, Vignesh; Jyothi, Mannekote Shivanna; Balakrishna, R Geetha; Padaki, Mahesh; Ismail, Ahmad Fauzi

    2015-06-01

    Herein we present a new approach for the complete removal of Cr(VI) species, through reduction of Cr(VI) to Cr(III), followed by adsorption of Cr(III). Reduction of chromium from water is an important challenge, as Cr(IV) is one of the most toxic substances emitted from industrial processes. Chitosan (CS) thin films were developed on plain polysulfone (PSf) and PSf/TiO2 membrane substrates by a temperature-induced technique using polyvinyl alcohol as a binder. Structure property elucidation was carried out by X-ray diffraction, microscopy, spectroscopy, contact angle measurement, and water uptake studies. The increase in hydrophilicity followed the order: PSf < PSf/TiO2 < PSf/TiO2/CS membranes. Use of this thin-film composite membrane for chromium removal was investigated with regards to the effects of light and pH. The observations reveal 100 % reduction of Cr(VI) to Cr(III) through electrons and protons donated from OH and NH2 groups of the CS layer; the reduced Cr(III) species are adsorbed onto the CS layer via complexation to give chromium-free water. PMID:26246989

  20. Complete genomic organization of the human erythroid p55 gene (MPP1), a membrane-associated guanylate kinase homologue

    SciTech Connect

    Kim, A.C.; Metzenberg, A.B.; Sahr, K.E.

    1996-01-15

    Human p55 is an abundantly palmitoylated phosphoprotein of the erythroid membrane. It is the prototype of a newly discovered family of membrane-associated proteins termed MAGUKs (membrane-associated guanylate kinase homologues). The MAGUKs interact with the cytoskeleton and regulate cell proliferation, signaling pathways, and intercellular junctions. Here, we report the complete intron-exon map of the human erythroid p55 gene (HGMW-approved symbol MPP1). The structure of the p55 gene was determined from cosmid clones isolated from a cosmid library specific for the human X chromosome. There is a single copy of the p55 gene, composed of 12 exons and spanning approximately 28 kb in the q28 region of the human X chromosome. The exon sizes range from 69 (exon 5) to 203 bp (intron 2) to {approximately}14 kb (intron 1). The intron-exon boundaries conform to the donor/acceptor consensus sequence, GT-AG, for splice junctions. Several of the exon boundaries correspond to the boundaries of functional domains in the p55 protein. These domains include a SH3 motif and a region that binds to cytoskeletal protein 4.1. In addition, a comparison of the genomic and the primary structures of p55 reveals a highly conserved phosphotyrosine domain located between the protein 4.1 binding domain and the guanylate kinase domain. Finally, promoter activity measurements of the region immediately upstream of the p55 gene, which contains several cis-elements commonly found in housekeeping genes, suggest that a CpG island may be associated with the p55 gene expression in vivo. 42 refs., 5 figs., 1 tab.

  1. Thrombotic Occlusion during Intravascular Ultrasonography-Guided Percutaneous Coronary Intervention of Stumpless Chronic Total Occlusion.

    PubMed

    Lee, Un Joo; Kim, Hyun Soo; Lee, Cheolhyun; Kim, Kwang-Yeol; Kim, Weon

    2014-12-01

    Percutaneous coronary intervention (PCI) of stumpless chronic total occlusion (CTO) lesions with a side branch stemming from the occlusion have a significantly lower treatment success rate because physicians cannot identify an accurate entry point with only conventional angiographic images. An intravascular ultrasonography (IVUS)-guided wiring technique might be useful for the penetration of stumpless CTO. We recently experienced thrombotic occlusion during an IVUS-guided stumpless CTO procedure. The cause of the thrombosis is not completely understood; the thrombosis may have been associated with the long use of the IVUS catheter. Special precautions should be taken to prevent thrombus in such cases. PMID:25568847

  2. Vertebrobasilar Artery Occlusion

    PubMed Central

    Schoen, Jessica C.; Boysen, Megan M.; Warren, Chase R.; Chakravarthy, Bharath; Lotfipour, Shahram

    2011-01-01

    The presentation of vertebrobasilar artery occlusion varies with the cause of occlusion and location of ischemia. This often results in delay in diagnosis. Areas of the brain supplied by the posterior circulation are difficult to visualize and usually require angiography or magnetic resonance imaging. Intravenous thrombolysis and local-intra arterial thrombolysis are the most common treatment approaches used. Recanalization of the occluded vessel significantly improves morbidity and mortality. Here we present a review of the literature and a case of a patient with altered mental status caused by vertebrobasilar artery occlusion. PMID:21691534

  3. Management of total restenotic occlusions.

    PubMed

    Werner, Gerald S; Moehlis, Hiller; Tischer, Karlheinz

    2009-05-01

    Among lesions with in-stent restenosis (ISR), the in-stent chronic re-occlusions (ISR-CTO) is a subset with particularly unfavourable features regarding both the repeat procedure success and the prevention of lesion recurrence. A review of the literature and personal databases reveals that the prevalence of complete occlusive ISR represents about 5-10% of all CTO lesions, with little evidence regarding the successful long-term treatment. In fact, these lesions had been excluded from large contemporary trials dealing with the best modality for ISR management, and which showed eventually the superiority of drug-eluting stents (DES) as compared to brachytherapy. Only a limited experience exists with brachytherapy for ISR-CTOs, showing an inferior outcome as compared to non-occlusive ISRs. The lack of large study experience is true also for DES, so that only anecdotal experience in small series of patients is available. In some of the recent studies of DES in CTOs, again, ISR-CTOs were not included. Our own experience shows a slightly lower primary success rate of about 70% in ISR-CTOs as compared to 85% in primary CTOs, with a slightly higher recurrence rate with DES of 25%. ISR-CTOs are a clinical problem that had not been systematically addressed. However, we hope that this lesion subset may be of less relevance in the future when the use of DES in lesions which are prone for lesion recurrence will lead to less diffuse and occlusive ISR, and leaves rather focal and better manageable recurrent lesions. PMID:19736077

  4. Acute arterial occlusion - kidney

    MedlinePlus

    Acute renal arterial thrombosis; Renal artery embolism; Acute renal artery occlusion; Embolism - renal artery ... kidneys need a good blood supply. The main artery to the kidney is called the renal artery. ...

  5. Retinal vein occlusion

    MedlinePlus

    ... Berrocal MH, Rodriguez FJ, et al. Pan-American Collaborative Retina Study Group (PACORES). Comparison of two doses ... retinal vein occlusion: results from the Pan-American Collaborative Retina Study Group at 6 months of follow- ...

  6. Pars Plana Vitrectomy Combined with Internal Limiting Membrane Peeling to Treat Persistent Macular Edema after Anti-Vascular Endothelial Growth Factor Treatment in Cases of Ischemic Central Retinal Vein Occlusion

    PubMed Central

    Shirakata, Yukari; Fujita, Tomoyoshi; Nakano, Yuki; Shiraga, Fumio; Tsujikawa, Akitaka

    2016-01-01

    Objective To evaluate the efficacy of pars plana vitrectomy (PPV) combined with internal limiting membrane (ILM) peeling in cases of ischemic central retinal vein occlusion (CRVO) where macular edema (ME) persisted after anti-vascular endothelial growth factor (anti-VEGF) treatment. Methods Fifteen eyes with ischemic CRVO-related ME were included in the study. Nine were treated with panretinal photocoagulation after initial examination. Anti-VEGF agents were injected intravitreally. Persistent ME was treated with PPV combined with ILM peeling. During surgery, laser photocoagulation was further applied to the non-perfused area. Results Mean retinal thickness gradually decreased after surgery (p = 0.024 at 6 months), although visual acuity did not improve significantly during the follow-up period (14.7 ± 11.6 months). Neovascular glaucoma subsequently developed in three cases and a trabeculectomy was performed in one case. Conclusion In eyes with ischemic CRVO, PPV combined with ILM peeling contributed to a reduction in persistent ME. However, there was no significant improvement in visual acuity. PMID:26889152

  7. The identification of an integral membrane, cytochrome c urate oxidase completes the catalytic repertoire of a therapeutic enzyme

    PubMed Central

    Doniselli, Nicola; Monzeglio, Enrico; Dal Palù, Alessandro; Merli, Angelo; Percudani, Riccardo

    2015-01-01

    In living organisms, the conversion of urate into allantoin requires three consecutive enzymes. The pathway was lost in hominid, predisposing humans to hyperuricemia and gout. Among other species, the genomic distribution of the two last enzymes of the pathway is wider than that of urate oxidase (Uox), suggesting the presence of unknown genes encoding Uox. Here we combine gene network analysis with association rule learning to identify the missing urate oxidase. In contrast with the known soluble Uox, the identified gene (puuD) encodes a membrane protein with a C-terminal cytochrome c. The 8-helix transmembrane domain corresponds to DUF989, a family without similarity to known proteins. Gene deletion in a PuuD-encoding organism (Agrobacterium fabrum) abolished urate degradation capacity; the phenotype was fully restored by complementation with a cytosolic Uox from zebrafish. Consistent with H2O2 production by zfUox, urate oxidation in the complemented strain caused a four-fold increase of catalase. No increase was observed in the wild-type, suggesting that urate oxidation by PuuD proceeds through cytochrome c-mediated electron transfer. These findings identify a missing link in purine catabolism, assign a biochemical activity to a domain of unknown function (DUF989), and complete the catalytic repertoire of an enzyme useful for human therapy. PMID:26349049

  8. Viewpoint-based ambient occlusion.

    PubMed

    González, Francisco; Sbert, Mateu; Feixas, Miquel

    2008-01-01

    A new ambient occlusion technique builds a channel between various viewpoints and an object's polygons, providing the information needed to create an occlusion map with multiple application possibilities. PMID:18350932

  9. Effect of partial or complete elimination of light-harvesting complexes on the surface electric properties and the functions of cyanobacterial photosynthetic membranes.

    PubMed

    Dobrikova, Anelia G; Domonkos, Ildikó; Sözer, Özge; Laczkó-Dobos, Hajnalka; Kis, Mihály; Párducz, Árpád; Gombos, Zoltán; Apostolova, Emilia L

    2013-02-01

    Influence of the modification of the cyanobacterial light-harvesting complex [i.e. phycobilisomes (PBS)] on the surface electric properties and the functions of photosynthetic membranes was investigated. We used four PBS mutant strains of Synechocystis sp. PCC6803 as follows: PAL (PBS-less), CK (phycocyanin-less), BE (PSII-PBS-less) and PSI-less/apcE(-) (PSI-less with detached PBS). Modifications of the PBS content lead to changes in the cell morphology and surface electric properties of the thylakoid membranes as well as in their functions, such as photosynthetic oxygen-evolving activity, P700 kinetics and energy transfer between the pigment-protein complexes. Data reveal that the complete elimination of PBS in the PAL mutant causes a slight decrease in the electric dipole moments of the thylakoid membranes, whereas significant perturbations of the surface charges were registered in the membranes without assembled PBS-PSII macrocomplex (BE mutant) or PSI complex (PSI-less mutant). These observations correlate with the detected alterations in the membrane structural organization. Using a polarographic oxygen rate electrode, we showed that the ratio of the fast to the slow oxygen-evolving PSII centers depends on the partial or complete elimination of light-harvesting complexes, as the slow operating PSII centers dominate in the PBS-less mutant and in the mutant with detached PBS. PMID:22582961

  10. Evidence-based considerations for removable prosthodontic and dental implant occlusion: a literature review.

    PubMed

    Taylor, Thomas D; Wiens, Jonathan; Carr, Alan

    2005-12-01

    The dental literature is filled with discussions of dental occlusion, occlusal schemes, philosophies, and methods to correct and restore the diseased, worn, or damaged occlusion. Traditionally, these discussions have been empirical in nature and not based on scientific evidence. Due to the empirical nature of the literature, the study of occlusion has been extremely complex and troublesome to both pre- and post-doctoral students. The introduction of osseointegrated implants has further complicated the situation. Dentists may apply the principles of occlusion for the natural dentition directly to implant-supported and retained restorations. Although this may be successful, this rationale may result in overly complex or simplified treatment protocols and outcomes. There is an emerging body of scientific literature related to dental implant therapy that may be useful in formulating treatment protocols and prosthesis designs for implant-supported restorations. This review focuses on some of the "classic" removable prosthodontic literature and the currently available scientific literature involving removable prosthodontic occlusion and dental implant occlusion. The authors reviewed the English peer-reviewed literature prior to 1996 in as comprehensive manner as possible, and material after 1996 was reviewed electronically using MEDLINE. Electronic searches of the literature were performed in MEDLINE using key words-animal studies, case series, clinical trials, cohort studies, complete denture occlusion, dental implant function, dental implant occlusion, dental implant occlusion research, dental implant functional loading, dental implants, dental occlusion, dental occlusion research, denture function, denture occlusion, dentures, implant function, implant functional loading, implant occlusion, occlusion, and removable partial denture occlusion-in various combinations to obtain potential references for review. A total of 5447 English language titles were obtained, many of

  11. Pulmonary veno-occlusive disease

    MedlinePlus

    ... occlusive disease is an extremely rare disease that causes high blood pressure in the lung arteries ( pulmonary hypertension ). ... In most cases, the cause of pulmonary veno-occlusive disease is ... arteries directly connected to the right side of the heart. The ...

  12. A comparison of the physical, chemical, and biological properties of sludges from a complete-mix activated sludge reactor and a submerged membrane bioreactor.

    PubMed

    Merlo, Rion P; Trussell, R Shane; Hermanowicz, Slawomir W; Jenkins, David

    2007-03-01

    The properties of sludges from a pilot-scale submerged membrane bioreactor (SMBR) and two bench-scale complete-mix, activated sludge (CMAS) reactors treating municipal primary effluent were determined. Compared with the CMAS sludges, the SMBR sludge contained a higher amount of soluble microbial products (SMP) and colloidal material attributed to the use of a membrane for solid-liquid separation; a higher amount nocardioform bacteria, resulting from efficient foam trapping; and a lower amount of extracellular polymeric substances (EPS), possibly because there was no selective pressure for the sludge to settle. High aeration rates in both the CMAS and SMBR reactors produced sludges with higher numbers of smaller particles. Normalized capillary suction time values for the SMBR sludge were lower than for the CMAS sludges, possibly because of its lower EPS content. PMID:17469664

  13. Discordant relationship between Essure microinsert position and tubal occlusion.

    PubMed

    Hou, Melody Y

    2016-01-01

    Hysteroscopic sterilisation with Essure requires confirmation of tubal occlusion by hysterosalpingogram or microinsert position by transvaginal sonography 3 months after placement before women can rely on the method for pregnancy prevention. A 39-year-old woman underwent hysteroscopic sterilisation via Essure, with successful bilateral tubal occlusion documented on hysterosalpingogram. She had a subsequent unintended pregnancy and termination, and presented with persistent pelvic pain and other non-specific symptoms. She underwent a laparoscopic-assisted vaginal hysterectomy with bilateral salpingectomy, with complete resolution of her symptoms. Pathological evaluation demonstrated a perforated Essure microinsert and ipsilateral tubal occlusion, and a correctly placed Essure microinsert with ipsilateral tubal patency. Clinicians should be cautious about the assumption that correctly placed microinserts based on ultrasonography, hysterosalpingogram or laparoscopic evaluation assures occlusion success. PMID:27466315

  14. Other cerebrovascular occlusive disease.

    PubMed

    Camargo, Erica C S; Schaefer, Pamela W; Singhal, Aneesh B

    2016-01-01

    In this chapter we review the optimal imaging modalities for subacute and chronic stroke. We discuss the utility of computed tomography (CT) and multimodal CT imaging. Further, we analyze the importance of specific magnetic resonance imaging sequences, such as diffusion-weighted imaging for acute ischemic stroke, T2/fluid-attenuated inversion recovery for subacute and chronic stroke, and susceptibility imaging for detection of intracranial hemorrhages. Different ischemic stroke mechanisms are reviewed, and how these imaging modalities may aid in the determination of such. Further, we analyze how topographic patterns in ischemic stroke may provide important clues to the diagnosis, in addition to the temporal evolution of the stroke. Lastly, specific cerebrovascular occlusive diseases are reviewed, with emphasis on the optimal imaging modalities and their findings in each condition. PMID:27432673

  15. Basilar Occlusion Syndromes

    PubMed Central

    Broderick, Joseph P.

    2015-01-01

    Basilar artery occlusions (BAOs) are a subset of posterior circulation strokes. Particular issues relevant to BAOs include variable and stuttering symptoms at onset resulting in delays in diagnosis, high morbidity and mortality, and uncertain best management. Despite better imaging techniques, diagnosis, and therefore treatment, is often delayed. We will present the most common signs and symptoms of posterior circulation strokes. Data on optimal treatment strategies are gathered from multiple case series, registries, and one randomized trial, which was stopped early. Possible etiologies of BAOs, acute, and subacute treatment strategies and special topics in neuroimaging of the posterior fossa are discussed. This review may be helpful to neurohospitalists who are managing patients with acute stroke as well as emergency room physicians and neurologists. PMID:26288672

  16. Measurement of regional forearm muscle haemodynamics via the near-infrared spectroscopy venous occlusion technique: the impact of hand circulatory occlusion.

    PubMed

    Cross, T J; van Beekvelt, M; Constantini, K; Sabapathy, S

    2014-12-01

    The purpose of this study was to examine whether circulatory occlusion of the hand impacts on regional forearm muscle haemodynamics as determined by the near-infrared spectroscopy (NIRS) venous occlusion technique (NIRSVOT). Twenty-five young, healthy participants (18 males and 7 females; 28 ± 4 years; 71 ± 7 kg) completed two experimental protocols that were performed on the dominant arm: (1) a series of five venous occlusion trials with a suprasystolic cuff (>260 mmHg) applied to the wrist and (2) five venous occlusion trials without hand-occlusion. Both protocols were performed twice in a counterbalanced manner. NIRS data were obtained from the flexor digitorum superficialis (FDS) muscle using a dual wavelength, continuous-wave spectrophotometer. FDS muscle blood flow (Q(FDS)), vascular conductance (C(FDS)), O2 consumption (Vo(2FDS)), and venous O2 saturation (SvO2) were calculated from NIRS data during the initial 5 s of venous occlusion. Circulatory occlusion of the hand via wrist cuffing significantly (P < 0.05) reduced Q(FDS) (-36 ± 23%), CFDS (-37 ± 23%), Vo2(FDS) (-14 ± 31%) and SvO2 (-14 ± 12%). These findings indicate that hand-occlusion, via wrist cuffing, adversely impacts on regional forearm haemodynamics as determined by the NIRS-VOT. Consequently, it is recommended that future investigators avoid hand-occlusion when using the NIRS-VOT to quantify spontaneous haemodynamics of regional forearm muscle. PMID:25419965

  17. Mechanism of vaso-occlusion in sickle cell anemia

    NASA Astrophysics Data System (ADS)

    Lei, Huan; Karniadakis, George

    2012-11-01

    Vaso-occlusion crisis is one of the key hallmark of sickle cell anemia. While early studies suggested that the crisis is caused by blockage of a single elongated cell, recent experimental investigations indicate that vaso-occlusion is a complex process triggered by adhesive interactions among different cell groups in multiple stages. Based on dissipative particle dynamics, a multi-scale model for the sickle red blood cells (SS-RBCs), accounting for diversity in both shapes and cell rigidities, is developed to investigate the mechanism of vaso-occlusion crisis. Using this model, the adhesive dynamics of single SS-RBC was investigated in arterioles. Simulation results indicate that the different cell groups (deformable SS2 RBCs, rigid SS4 RBCs, leukocytes, etc.) exhibit heterogeneous adhesive behavior due to the different cell morphologies and membrane rigidities. We further simulate the tube flow of SS-RBC suspensions with different cell fractions. The more adhesive SS2 cells interact with the vascular endothelium and further trap rigid SS4 cells, resulting in vaso-occlusion in vessels less than 15 μm . Under inflammation, adherent leukocytes may also trap SS4 cells, resulting in vaso-occlusion in even larger vessels. This work was supported by the NSF grant CBET-0852948 and the NIH grant R01HL094270.

  18. A haemolytic syndrome associated with the complete absence of red cell membrane protein 4.2 in two Tunisian siblings.

    PubMed

    Ghanem, A; Pothier, B; Marechal, J; Ducluzeau, M T; Morle, L; Alloisio, N; Feo, C; Ben Abdeladhim, A; Fattoum, S; Delaunay, J

    1990-07-01

    We report on the complete absence of protein 4.2 in two Tunisian siblings. The propositus presented with a haemolytic anaemia that evolved in an intermittent fashion until she was cured by splenectomy. Her red cells had a normal morphology, as well as normal deformability upon osmotic gradient ektacytometry. SDS-polyacrylamide gel electrophoresis failed to reveal any protein 4.2. Using anti-protein 4.2 polyclonal antibodies. Western blots were also unable to detect protein 4.2. Preparation of inside out vesicles resulted in no detectable loss of ankyrin. The propositus's sister presented with a haemolytic anaemia but had not undergone splenectomy; she showed the same biochemical features. The two cases presented of missing protein 4.2 are the first ones to be described outside the Japanese population. Considered as homozygotes for some defect that must alter the protein 4.2 gene itself, they exemplify a unique syndrome pertaining neither to elliptocytosis nor to spherocytosis, at least not closely. The parents, who are first cousins and whom we regarded as heterozygotes, were clinically and morphologically normal; they had a normal content of protein 4.2. Therefore, the 4.2 (-) haemolytic anaemia appears as entirely recessive. PMID:2386772

  19. Prevalent misconceptions about acute retinal vascular occlusive disorders.

    PubMed

    Hayreh, Sohan Singh

    2005-07-01

    Acute retinal vascular occlusive disorders collectively constitute one of the major causes of blindness or seriously impaired vision, and yet there is marked controversy on their pathogeneses, clinical features and particularly their management. This is because the subject is plagued by multiple misconceptions. These include that: (i) various acute retinal vascular occlusions represent a single disease; (ii) estimation of visual acuity alone provides all the information necessary to evaluate visual function; (iii) retinal venous occlusions are a single clinical entity; (iv) retinal vein occlusion is essentially a disease of the elderly and is not seen in the young; (v) central retinal vein occlusion (CRVO) is one disease; (vi) fluorescein fundus angiography is the best test to differentiate ischemic from nonischemic CRVO; (vii) the site of occlusion in CRVO is invariably at the lamina cribrosa; (viii) clinical picture of CRVO is often due to compression or strangulation of the central retinal vein (CRV) in the lamina cribrosa and not its occlusion; (ix) an eye can develop both CRVO and central retinal artery occlusion (CRAO) simultaneously; (x) every eye with CRVO is at risk of developing neovascular glaucoma; (xi) lowering intraocular pressure (IOP) helps to improve retinal circulation in an eye with CRVO; (xii) every patient with retinal vein occlusion should have complete hematologic and coagulation evaluation; (xiii) the natural history of CRVO does not usually involve spontaneous visual improvement; (xiv) management of CRVO is similar to that of venous thrombosis anywhere else in the body, i.e. with aspirin and/or anti-coagulants; (xv) fibrinolytic agents can dissolve an organized thrombus in the CRV; (xvi) it is beneficial to lower blood pressure in patients with CRVO; (xvii) panretinal photocoagulation used in ischemic retinal venous occlusive disorders has no deleterious side-effects; (xviii) glaucoma or ocular hypertension can cause branch retinal vein

  20. Scintigraphic patterns of veno-occlusive disease in liver transplantation.

    PubMed

    Bernstine, Hanna; Mor, Eytan; Ben Ari, Ziv; Belinki, Alexander; Hardoff, Ruth

    2004-05-01

    Venous vascular complications in liver transplant recipients are rare. Diagnosis is usually based on clinical criteria and typical findings on liver biopsy. The scintigraphic patterns of posttransplant liver veno-occlusive disease are described, and the value of follow-up studies is suggested. The authors present 2 patients who developed posttransplantation hepatic veno-occlusive disease. The first patient had a severe form of the disease and a fatal outcome. The second patient had a mild to moderate form of this disorder with complete resolution following treatment. PMID:15069326

  1. Double steal phenomenon secondary to innominate artery occlusion.

    PubMed

    Esen, Kaan; Yilmaz, Cengiz; Kaya, Omer; Soker, Gokhan; Gulek, Bozkurt; Sahin, Durmus Yildiray

    2016-07-01

    Innominate artery steno-occlusive disease is a relatively rare clinical entity and may cause cerebrovascular symptoms. Herein, we report a 50-year-old male patient who presented with recurrent syncopal episodes and cerebrovascular ischemia. Color Doppler sonography revealed a distinctive flow pattern with partial and total flow reversal in the right internal carotid artery and vertebral artery, respectively. Further angiographic evaluation revealed complete occlusion of the innominate artery. Endovascular stenting was successful and enabled normal antegrade flow in the right common carotid and vertebral artery. PMID:27107766

  2. Pulmonary veno-occlusive disease

    MedlinePlus

    ... disorder. Alternative Names Pulmonary vaso-occlusive disease Images Respiratory system References Channick RN, Rubin LJ. Pulmonary hypertension. In: Mason RJ, Broaddus VC, Martin TR, et al., eds. Murray and Nadel's Textbook of Respiratory Medicine . 5th ed. Philadelphia, PA: Elsevier Saunders; 2010: ...

  3. Direct Pressure Monitoring Accurately Predicts Pulmonary Vein Occlusion During Cryoballoon Ablation

    PubMed Central

    Kosmidou, Ioanna; Wooden, Shannnon; Jones, Brian; Deering, Thomas; Wickliffe, Andrew; Dan, Dan

    2013-01-01

    Cryoballoon ablation (CBA) is an established therapy for atrial fibrillation (AF). Pulmonary vein (PV) occlusion is essential for achieving antral contact and PV isolation and is typically assessed by contrast injection. We present a novel method of direct pressure monitoring for assessment of PV occlusion. Transcatheter pressure is monitored during balloon advancement to the PV antrum. Pressure is recorded via a single pressure transducer connected to the inner lumen of the cryoballoon. Pressure curve characteristics are used to assess occlusion in conjunction with fluoroscopic or intracardiac echocardiography (ICE) guidance. PV occlusion is confirmed when loss of typical left atrial (LA) pressure waveform is observed with recordings of PA pressure characteristics (no A wave and rapid V wave upstroke). Complete pulmonary vein occlusion as assessed with this technique has been confirmed with concurrent contrast utilization during the initial testing of the technique and has been shown to be highly accurate and readily reproducible. We evaluated the efficacy of this novel technique in 35 patients. A total of 128 veins were assessed for occlusion with the cryoballoon utilizing the pressure monitoring technique; occlusive pressure was demonstrated in 113 veins with resultant successful pulmonary vein isolation in 111 veins (98.2%). Occlusion was confirmed with subsequent contrast injection during the initial ten procedures, after which contrast utilization was rapidly reduced or eliminated given the highly accurate identification of occlusive pressure waveform with limited initial training. Verification of PV occlusive pressure during CBA is a novel approach to assessing effective PV occlusion and it accurately predicts electrical isolation. Utilization of this method results in significant decrease in fluoroscopy time and volume of contrast. PMID:23485956

  4. Direct pressure monitoring accurately predicts pulmonary vein occlusion during cryoballoon ablation.

    PubMed

    Kosmidou, Ioanna; Wooden, Shannnon; Jones, Brian; Deering, Thomas; Wickliffe, Andrew; Dan, Dan

    2013-01-01

    Cryoballoon ablation (CBA) is an established therapy for atrial fibrillation (AF). Pulmonary vein (PV) occlusion is essential for achieving antral contact and PV isolation and is typically assessed by contrast injection. We present a novel method of direct pressure monitoring for assessment of PV occlusion. Transcatheter pressure is monitored during balloon advancement to the PV antrum. Pressure is recorded via a single pressure transducer connected to the inner lumen of the cryoballoon. Pressure curve characteristics are used to assess occlusion in conjunction with fluoroscopic or intracardiac echocardiography (ICE) guidance. PV occlusion is confirmed when loss of typical left atrial (LA) pressure waveform is observed with recordings of PA pressure characteristics (no A wave and rapid V wave upstroke). Complete pulmonary vein occlusion as assessed with this technique has been confirmed with concurrent contrast utilization during the initial testing of the technique and has been shown to be highly accurate and readily reproducible. We evaluated the efficacy of this novel technique in 35 patients. A total of 128 veins were assessed for occlusion with the cryoballoon utilizing the pressure monitoring technique; occlusive pressure was demonstrated in 113 veins with resultant successful pulmonary vein isolation in 111 veins (98.2%). Occlusion was confirmed with subsequent contrast injection during the initial ten procedures, after which contrast utilization was rapidly reduced or eliminated given the highly accurate identification of occlusive pressure waveform with limited initial training. Verification of PV occlusive pressure during CBA is a novel approach to assessing effective PV occlusion and it accurately predicts electrical isolation. Utilization of this method results in significant decrease in fluoroscopy time and volume of contrast. PMID:23485956

  5. Association between occlusal force and physical functions in preschool children: a comparison of males and females

    PubMed Central

    Hirao, Aya; Murata, Shin; Kubo, Atsuko; Hachiya, Mizuki; Mitsumaru, Nozomi; Asami, Toyoko

    2015-01-01

    [Purpose] To determine and compare changes over time in the physical strength of male and female children aged 4–5 years by measuring physical functions such as occlusal forces. [Subjects and Methods] The occlusal force, weight, height, grip strength, standing long jump, ball throwing, timed up and go (TUG), and the 25-m run time were measured of 331 children to determine their physical strength. All the children understood and were capable of completing all tests. [Results] Occlusal force among male infants significantly correlated with all items except ball throwing. Stepwise multiple regression analysis independently associated occlusal force with grip strength. In contrast, occlusal force of female infants significantly correlated with all the tested items. Stepwise multiple regression analysis also independently associated occlusal force with grip strength and TUG in females. [Conclusion] Grip strength indicating upper-limb muscle strength correlated with occlusal forces in both male and female children, whereas TUG, balance and walking ability indicating muscle strength of the lower limbs, correlated with items relevant to everyday functions in female infants. These findings show that different factors are involved in the occlusal forces of male and female children. PMID:26834340

  6. Thermography in Occlusive Cerebrovascular Diseases

    PubMed Central

    Mawdsley, C.; Samuel, E.; Sumerling, M. D.; Young, G. B.

    1968-01-01

    Cooling of the skin over the medial supraorbital region in 80% of patients who have an occlusion or severe stenosis of a carotid artery can be demonstrated by facial thermography. Minor stenotic lesions in the carotid arteries do not produce characteristic thermographic changes, while thermography is of no help in the diagnosis of vertebrobasilar arterial disease. Thermographic changes suggestive of carotid arterial lesions are found occasionally in patients whose angiograms are normal, owing to variations in the size of the frontal sinuses, or factors such as fever or inflammatory lesions. It is suggested that facial thermography is of value in the preliminary investigation of patients with occlusive cerebrovascular disease. ImagesFig. 1Fig. 2Fig. 3Fig. 4Fig. 5Fig. 6 PMID:5676953

  7. Retinal vein occlusion: current treatment.

    PubMed

    Lattanzio, Rosangela; Torres Gimeno, Ana; Battaglia Parodi, Maurizio; Bandello, Francesco

    2011-01-01

    Retinal vein occlusion (RVO) is a pathology noted for more than 150 years. Although a lot has been written on the matter, it is still a frequent condition with multifactorial etiopathogenesis with many unclear aspects. The RVO pathogenesis has varied systemic and local implications that make it difficult to elaborate treatment guidelines. The management of the patient with RVO is very complex and a multidisciplinary approach is required in order to identify and correct the associated risk factors. Laser therapy remains the gold standard in RVO, but only modest functional improvement has been shown in branch retinal occlusion forms. Multicenter studies of intravitreal drugs present them as an option to combine with laser. Anti-vascular endothelial growth factor, corticosteroids and sustained-release implants are the future weapons to stop disease progression and get a better visual outcome. Consequently, it is useful to clarify some aspects of the pathology that allow a better patient management. PMID:20938213

  8. Venous occlusive diseases in women.

    PubMed

    Ozsvath, Kathleen J; Moore, Colleen J

    2013-04-01

    Women have a high incidence of chronic venous disease. Venous occlusive disease can lead to significant morbidity and even death. Factors such as genetics, medications, and diseases can play a role in the development of venous thrombosis. In women, pregnancy can lead to a hypercoagulable state and a greater risk of venous complication. Awareness and education will be very important in the future to help identify those patients at risk. PMID:23522718

  9. Rehabilitation of occlusion - science or art?

    PubMed

    Koyano, K; Tsukiyama, Y; Kuwatsuru, R

    2012-07-01

    The primary objective of rehabilitating occlusion is to improve stomatognathic function in patients experiencing dysfunction in mastication, speech, and swallowing as a consequence of tooth loss. The procedure of occlusal treatment involves improving the morphology and the stomatognathic function. Several practical methods and morphological endpoints have been described in occlusal rehabilitation. We made a selection of these (mandibular position, occlusal plane, occlusal guidance, occlusal contact, face-bow transfer, use of an adjustable articulator and occlusal support) and performed a literature review to verify the existence of compelling scientific evidence for each of these. A literature search was conducted using Medline/PubMed in March 2011. Over 400 abstracts were reviewed, and more than 50 manuscripts selected. An additional hand search was also conducted. Of the many studies investigating stomatognathic function in relation to specific occlusal schemes, most studies were poorly designed and of low quality, thus yielding ambiguous results. Overall, there is no scientific evidence that supports any specific occlusal scheme being superior to others in terms of improving stomatognathic function, nor that sophisticated methods are superior to simpler ones in terms of clinical outcomes. However, it is obvious that the art of occlusal rehabilitation requires accurate, reproducible, easy and quick procedures to reduce unnecessary technical failures and/or the requirement for compensatory adjustments. Therefore, despite the lack of scientific evidence for specific treatments, the acquisition of these general skills by dentists and attaining profound knowledge and skills in postgraduate training will be necessary for specialists in charge of complicated cases. PMID:22489962

  10. Life-threatening Cerebral Edema Caused by Acute Occlusion of a Superior Vena Cava Stent

    SciTech Connect

    Sofue, Keitaro Takeuchi, Yoshito Arai, Yasuaki; Sugimura, Kazuro

    2013-02-15

    A71-year-old man with advanced lung cancer developed a life-threatening cerebral edema caused by the acute occlusion of a superior vena cava (SVC) stent and was successfully treated by an additional stent placement. Although stent occlusion is a common early complication, no life-threatening situations have been reported until now. Our experience highlights the fact that acute stent occlusion can potentially lead to the complete venous shutdown of the SVC, resulting in life-threatening cerebral edema, after SVC stent placement. Immediate diagnosis and countermeasures are required.

  11. Modification of polyurethane to reduce occlusion of enteral feeding tubes

    SciTech Connect

    Gaither, Kari A.; Tarasevich, Barbara J.; Goheen, Steven C.

    2009-04-27

    Feeding tubes are used to supply nutritional formula to immobilized patients. The most common cause for failure of enteral feeding tubes is their occlusion. The purpose of this study was to examine whether occlusion of enteral feeding tubes could be minimized using an additive. An open, intermittent enteral feeding system was simulated in the laboratory and data was collected over a period ranging from 2 to 6 days. Feeding formula was cycled through a feeding tube in either the presence or absence of simulated gastric acid in an effort to generate a reproducible occlusion. Pressures in the tube were measured frequently throughout these cycles. We observed pressure spikes with each cycle, but never a complete occlusion. Pressure spikes formed only when simulated gastric acid was mixed with the feeding solution. Large amounts of feeding formula adsorbed onto polyurethane surfaces in the presence of gastric acid. The maximum pressure was reduced by about half from 2.0 psi to 0.8 psi when polyvinyl alcohol (PVA) was added. The addition of PVA to polyurethane also reduced the contact angle from 83° (untreated) to approximately 64° in the presence of PVA. Furthermore, when formula was added to polyurethane in the presence of PVA the thickness of the layer that remained on the surface was almost 10 times greater in controls than on PVA-treated surfaces. These results suggest that a treatment that increases the hydrophilicity of the feeding tube may help minimize clogging.

  12. ACUTE RETINAL ARTERIAL OCCLUSIVE DISORDERS

    PubMed Central

    Hayreh, Sohan Singh

    2011-01-01

    The initial section deals with basic sciences; among the various topics briefly discussed are the anatomical features of ophthalmic, central retinal and cilioretinal arteries which may play a role in acute retinal arterial ischemic disorders. Crucial information required in the management of central retinal artery occlusion (CRAO) is the length of time the retina can survive following that. An experimental study shows that CRAO for 97 minutes produces no detectable permanent retinal damage but there is a progressive ischemic damage thereafter, and by 4 hours the retina has suffered irreversible damage. In the clinical section, I discuss at length various controversies on acute retinal arterial ischemic disorders. Classification of acute retinal arterial ischemic disorders These are of 4 types: CRAO, branch retinal artery occlusion (BRAO), cotton wools spots and amaurosis fugax. Both CRAO and BRAO further comprise multiple clinical entities. Contrary to the universal belief, pathogenetically, clinically and for management, CRAO is not one clinical entity but 4 distinct clinical entities – non-arteritic CRAO, non-arteritic CRAO with cilioretinal artery sparing, arteritic CRAO associated with giant cell arteritis (GCA) and transient non-arteritic CRAO. Similarly, BRAO comprises permanent BRAO, transient BRAO and cilioretinal artery occlusion (CLRAO), and the latter further consists of 3 distinct clinical entities - non-arteritic CLRAO alone, non-arteritic CLRAO associated with central retinal vein occlusion and arteritic CLRAO associated with GCA. Understanding these classifications is essential to comprehend fully various aspects of these disorders. Central retinal artery occlusion The pathogeneses, clinical features and management of the various types of CRAO are discussed in detail. Contrary to the prevalent belief, spontaneous improvement in both visual acuity and visual fields does occur, mainly during the first 7 days. The incidence of spontaneous visual

  13. Vertebral artery occlusion and oral contraceptives.

    PubMed Central

    Ask-Upmark, E; Bickerstaff, E R

    1976-01-01

    If vertebral artery occlusion occurs in degenerative arterial disease it is almost invariably left-sided, but in vertebral artery deficiency syndromes associated with oral contraceptives a striking preponderance of right-sided involvement has been shown. This observation adds support to the view that causes other than changes in the wall of the vessel at the site of occlusion must be sought as an explanation of the occlusion. PMID:1252812

  14. Direct and complete phosphorus recovery from municipal wastewater using a hybrid microfiltration-forward osmosis membrane bioreactor process with seawater brine as draw solution.

    PubMed

    Qiu, Guanglei; Law, Yi-Ming; Das, Subhabrata; Ting, Yen-Peng

    2015-05-19

    We report a hybrid microfiltration-forward osmosis membrane bioreactor (MF-FOMBR) for direct phosphorus recovery from municipal wastewater in the course of its treatment. In the process, a forward osmosis (FO) membrane and a microfiltration (MF) membrane are operated in parallel in a bioreactor. FO membrane rejects the nutrients (e.g., PO4(3-), Ca(2+), Mg(2+), etc.) and results in their enrichment in the bioreactor. The nutrients are subsequently extracted via the MF membrane. Phosphorus is then recovered from the nutrients enriched MF permeate via precipitation without addition of an external source of calcium or magnesium. The use of seawater brine as a draw solution (DS) is another novel aspect of the system. The process achieved 90% removal of total organic carbon and 99% removal of NH4(+)-N. 97.9% of phosphate phosphorus (PO4(3-)-P) was rejected by the FO membrane and enriched within the bioreactor. >90% phosphorus recovery was achieved at pH 9.0. The precipitates were predominantly amorphous calcium phosphate with a phosphorus content of 11.1-13.3%. In principal, this process can recover almost all the phosphorus, apart from that assimilated by bacteria for growth. Global evaluation showed an overall phosphorus recovery of 71.7% over 98 days. PMID:25919506

  15. A novel method to determine perineal artery occlusion among male bicyclists

    PubMed Central

    Hotaling, James M.; Kathrins, Martin; Baftiri, Amit P.; Freels, Sally; Niederberger, Craig S.

    2015-01-01

    Background. Perineal pressure due to bicycle riding has been associated with erectile dysfunction. We developed a novel method to measure the occlusive force exerted over the perineal arteries and determined perineal artery occlusion by a variety of seat designs. Methods. Doppler ultrasonography facilitated perineal artery localization and determination of the force required for perineal artery occlusion in 20 healthy men. Flexiforce® sensors were affixed over the proximal and distal aspects of the perineal arteries bilaterally. Individuals completed bicycle rides in the road- and stationary-settings with six distinct seat designs, including those with and without an anterior “nose.” Results. The occlusion time proportion of the total ride time was calculated for each trial. The overall occlusion time proportion was 0.59 (95% CI [0.45–0.73]) across all seats and settings. The “no-nose” bicycle seat and the stationary-setting demonstrated significantly lower occlusion proportion times than the traditional nose bicycle seat and road-setting, respectively. However, all bicycle seats yielded an occlusion time proportion of 0.41 or greater. Discussion. Our method of real-time, non-invasive force measurement localized to the perineal arteries may be used to validate future bicycle seat design. It also underscores the significant risk of perineal artery insufficiency in men who are avid bicyclists. This risk may be minimized by using newer “no-nose” bicycle seats. PMID:26713236

  16. A novel method to determine perineal artery occlusion among male bicyclists.

    PubMed

    Parthiban, Sujeeth; Hotaling, James M; Kathrins, Martin; Baftiri, Amit P; Freels, Sally; Niederberger, Craig S

    2015-01-01

    Background. Perineal pressure due to bicycle riding has been associated with erectile dysfunction. We developed a novel method to measure the occlusive force exerted over the perineal arteries and determined perineal artery occlusion by a variety of seat designs. Methods. Doppler ultrasonography facilitated perineal artery localization and determination of the force required for perineal artery occlusion in 20 healthy men. Flexiforce(®) sensors were affixed over the proximal and distal aspects of the perineal arteries bilaterally. Individuals completed bicycle rides in the road- and stationary-settings with six distinct seat designs, including those with and without an anterior "nose." Results. The occlusion time proportion of the total ride time was calculated for each trial. The overall occlusion time proportion was 0.59 (95% CI [0.45-0.73]) across all seats and settings. The "no-nose" bicycle seat and the stationary-setting demonstrated significantly lower occlusion proportion times than the traditional nose bicycle seat and road-setting, respectively. However, all bicycle seats yielded an occlusion time proportion of 0.41 or greater. Discussion. Our method of real-time, non-invasive force measurement localized to the perineal arteries may be used to validate future bicycle seat design. It also underscores the significant risk of perineal artery insufficiency in men who are avid bicyclists. This risk may be minimized by using newer "no-nose" bicycle seats. PMID:26713236

  17. Feasibility of laser targeted photo-occlusion of ocular vessels.

    PubMed Central

    Asrani, S; Zeimer, R

    1995-01-01

    AIMS/BACKGROUND--Neovascularisation occurs in many major ocular diseases such as diabetes, age-related macular degeneration, and sickle cell disease. Laser photocoagulation is typically used to obliterate the vessels but it also causes severe damage to adjacent normal tissues. This is a very significant limitation especially in the treatment of choroidal neovascularisation which often covers large areas of the posterior pole and the fovea. A method, laser targeted delivery, has been developed capable of releasing drugs locally and non-invasively in the choroidal or retinal vasculature. This method could be used to target a photo-sensitiser to neovascular membranes and cause their selective occlusion by irradiating them. The targeting properties of the method promise to yield a treatment for neovascularisation that does not damage adjacent tissues and thus preserves vision. The purpose of the present study was to test the feasibility of occluding ocular vessels with this method. METHOD--The iris vessels of the albino rat were chosen because the treatment could be assessed unequivocally and followed with time. Aluminium phthalocyanine tetrasulphonate was encapsulated in heat sensitive liposomes and administered systemically. The iris vessels were irradiated with a yellow laser to raise their temperature to 41 degrees C, cause a phase transition in the liposomes and thereby locally release the photosensitiser. The laser was also used to excite the released photosensitiser and cause occlusion. The effect was monitored immediately and for 8 months thereafter. Controls for the effect of the laser and the unencapsulated drug were conducted. RESULTS--The results demonstrated that occlusion can be achieved and sustained for the period of follow up. The controls showed that the effect was not due to heat or to the activation of the low dose of free drug. CONCLUSION--These preliminary findings indicate that laser targeted photo-occlusion is a promising new method for the

  18. Occlusion on oral implants: current clinical guidelines.

    PubMed

    Koyano, K; Esaki, D

    2015-02-01

    Proper implant occlusion is essential for adequate oral function and the prevention of adverse consequences, such as implant overloading. Dental implants are thought to be more prone to occlusal overloading than natural teeth because of the loss of the periodontal ligament, which provides shock absorption and periodontal mechanoreceptors, which provide tactile sensitivity and proprioceptive motion feedback. Although many guidelines and theories on implant occlusion have been proposed, few have provided strong supportive evidence. Thus, we performed a narrative literature review to ascertain the influence of implant occlusion on the occurrence of complications of implant treatment and discuss the clinical considerations focused on the overloading factors at present. The search terms were 'dental implant', 'dental implantation', 'dental occlusion' and 'dental prosthesis'. The inclusion criteria were literature published in English up to September 2013. Randomised controlled trials (RCTs), prospective cohort studies and case-control studies with at least 20 cases and 12 months follow-up interval were included. Based on the selected literature, this review explores factors related to the implant prosthesis (cantilever, crown/implant ratio, premature contact, occlusal scheme, implant-abutment connection, splinting implants and tooth-implant connection) and other considerations, such as the number, diameter, length and angulation of implants. Over 700 abstracts were reviewed, from which more than 30 manuscripts were included. We found insufficient evidence to establish firm clinical guidelines for implant occlusion. To discuss the ideal occlusion for implants, further well-designed RCTs are required in the future. PMID:25284468

  19. Angiographic evidence of coronary occlusion and resolution

    PubMed Central

    Kavanagh-Gray, Doris

    1974-01-01

    A case of myocardial infarction with angiographically demonstrated occlusion of the left anterior descending coronary artery is presented. Repeat angiography 18 months later revealed patent coronary arteries despite persistent electrocardiographic infarction pattern. Coronary artery occlusion resulting in infarction may not, therefore, be permanent. ImagesFIG. 2 PMID:4824968

  20. A rare case of branch retinal vein occlusion following Sirsasana.

    PubMed

    Balamurugan, Anugraha; Srikanth, Krishnagopal

    2016-01-01

    Sirsasana is a type of headstand postural yoga in which the body is completely inverted. It is performed with or without wall support. In this position, the body is held upright supported by the forearms, while the crown of the head rests lightly on the floor. This is an advanced pose and should be attempted under the supervision of a qualified yoga instructor. The practice of Sirsasana is postulated to increase blood flow to the brain, improving memory, and other intellectual functions. It is also known to cause causes raised intraocular pressure, decompression retinopathy, glaucomatous visual field defects, central retinal vein occlusion, progression of glaucoma, optic neuropathy, and conjunctival varix thrombosis. We report a case of branch retinal vein occlusion following Sirsasana in a patient with systemic hypertension. PMID:27512326

  1. A rare case of branch retinal vein occlusion following Sirsasana

    PubMed Central

    Balamurugan, Anugraha; Srikanth, Krishnagopal

    2016-01-01

    Sirsasana is a type of headstand postural yoga in which the body is completely inverted. It is performed with or without wall support. In this position, the body is held upright supported by the forearms, while the crown of the head rests lightly on the floor. This is an advanced pose and should be attempted under the supervision of a qualified yoga instructor. The practice of Sirsasana is postulated to increase blood flow to the brain, improving memory, and other intellectual functions. It is also known to cause causes raised intraocular pressure, decompression retinopathy, glaucomatous visual field defects, central retinal vein occlusion, progression of glaucoma, optic neuropathy, and conjunctival varix thrombosis. We report a case of branch retinal vein occlusion following Sirsasana in a patient with systemic hypertension. PMID:27512326

  2. Promoter occlusion: transcription through a promoter may inhibit its activity.

    PubMed

    Adhya, S; Gottesman, M

    1982-07-01

    Induction of prophage lambda inhibits the expression of the gal operon from its cognate promoters. The effect is observed only in cis, and is due to frequent transcription of the gal promoter region by RNA polymerase molecules initiating upstream at the prophage PL promoter. The frequency of transcription initiation at PL is some 30 times greater than that at the gal promoter, Pg1. PL is one of the strongest procaryotic promoters. This "promoter occlusion" is essentially complete when the distance between gal and PL is small (less than or equal to 10 kb); and when PL is fully active (that is, in the absence of the cl or cro repressors). We discuss the possibility that promoter occlusion at two lambda promoters, Pint and PR', might play a role in the sequential expression of viral functions. PMID:6217898

  3. Occlusion Detection by Height Gradient for True Orthophoto Generation, Using LIDAR Data

    NASA Astrophysics Data System (ADS)

    Oliveira, H. C.; Galo, M.

    2013-05-01

    Nowadays, the use of orthophoto in urban areas has become common. It is known that in most parts of urban areas there are a great number of tall buildings which can cause occlusion regions during image acquisition. These occlusions appear both in aerial images and in the orthophotos generated from these images. It happens due to perspective projection of the imaging sensor, and also if digital models that represent only relief is used in the orthorectification process, instead of the Digital Surface Model (DSM) that takes into account the relief and all objects on the surface. Considering this context, the aim of this article is to introduce an alternative procedure for occlusion detection in aerial images, using LiDAR (Light Detection And Ranging) data, aiming at the generation of true orthophotos. The presented method for occlusion detection is based on height gradient computation applied to a DSM of the region, instead of the building model that is considered in some approaches. These height gradients computed in radial directions are important for the identification of the beginning of the occlusions in these directions. The final limits of the occlusions are obtained from the projection of these initial points in the DSM. To evaluate the proposed method, both simulated and real data were considered. The simulated data correspond to an ideal urban area, without noise, and this experiment was only used to validate the implementation method. The real data set is composite by digital aerial images and LiDAR data. The LiDAR data available has the average density of 8 points/m2. As preliminary results, the occlusion areas were detected and highlighted in the orthorectified images. To accomplish the evaluation of the proposed method, besides a visual analysis, a numerical evaluation based on index of completeness was computed, using as reference a manual detection of occlusion. It is possible to observe the potential of the proposed occlusion detection method

  4. Bilateral mechanical rotational vertebral artery occlusion.

    PubMed

    Dargon, Phong T; Liang, Conrad W; Kohal, Anmol; Dogan, Aclan; Barnwell, Stanley L; Landry, Gregory J

    2013-10-01

    Rotational vertebral artery occlusion, or bow hunter's stroke, is reversible, positional symptomatic vertebrobasilar ischemia. The typical mechanism of action is obstruction of a dominant vertebral artery with contralateral head rotation in the setting of baseline ipsilateral vertebral artery stenosis or occlusion. Here we present a rare case of mechanical occlusion of bilateral patent vertebral arteries manifesting as near syncope with rightward head rotation. Diagnostic cerebral angiography showed dynamic right C5 vertebral occlusion and left C2 vertebral occlusion. The patient underwent right C4/5 transverse process decompression. Postoperative angiogram showed patent flow through the right vertebral artery in neutral position and with head turn with resultant resolution of symptoms. PMID:23465174

  5. Relationship between occlusal plane and ala-tragus line in dentate individuals: A Clinical pilot study.

    PubMed

    Nayar, Sanjna; Bhuminathan, S; Bhat, Wasim Manzoor; Mahadevan, R

    2015-04-01

    Many methods have been used to establish the occlusal plane in complete denture prosthodontics. However, no single method seems to be fully accepted. Anteriorly, esthetic considerations help define the occlusal plane, and posteriorly the tongue, retromolar pad, and Stenson's duct are considered. Some dentists bisect the space between the residual ridges. The technique of using the ala-tragus line (Camper's line) to establish the occlusal plane is well documented. However, definitions of the ala-tragus line cause confusion, because the exact points of reference do not agree. For example, the glossary of prosthodontic terms states that the ala-tragus line runs from the inferior border of the ala of the nose to the superior border of the tragus of the ear while Spratley' describes it as running from the center of the ala to the center of the tragus. This article concerns us the exact relationship between the occlusal plane and ala-tragus line in dentate individuals. PMID:26015765

  6. Perceptual Completion in Newborn Human Infants

    ERIC Educational Resources Information Center

    Valenza, Eloisa; Leo, Irene; Gava, Lucia; Simion, Francesca

    2006-01-01

    Despite decades of studies of human infants, a still open question concerns the role of visual experience in the development of the ability to perceive complete shapes over partial occlusion. Previous studies show that newborns fail to manifest this ability, either because they lack the visual experience required for perceptual completion or…

  7. Special report: Occlusive cuff controller

    NASA Technical Reports Server (NTRS)

    Baker, J. T.

    1975-01-01

    A mechanical occlusive cuff controller suitable for blood flow experiments in space shuttle flights is described. The device requires 115 volt ac power and a pressurized gas source. Two occluding cuff pressures (30 and 50 mmHg) are selectable by a switch on the front panel. A screw driver adjustment allows accurate cuff pressurization levels for under or oversized limbs. Two pressurization cycles (20 second and 2 minutes) can be selected by a front panel switch. Adjustment of the timing cycles is also available through the front panel. A pushbutton hand switch allows remote start of the cuff inflation cycle. A stop/reset switch permits early termination of the cycle and disabling of the controller to prevent inadvertent reactivation. Pressure in the cuff is monitored by a differential aneroid barometer. In addition, an electrocardiogram trigger circuit permits the initiation of the pressurization cycle by an externally supplied ECG cycle.

  8. Occlusion for stimulus deprivation amblyopia

    PubMed Central

    Antonio-Santos, Aileen; Vedula, Satyanarayana S; Hatt, Sarah R; Powell, Christine

    2014-01-01

    Background Stimulus deprivation amblyopia (SDA) develops due to an obstruction to the passage of light secondary to a condition such as cataract. The obstruction prevents formation of a clear image on the retina. SDA can be resistant to treatment, leading to poor visual prognosis. SDA probably constitutes less than 3% of all amblyopia cases, although precise estimates of prevalence are unknown. In developed countries, most patients present under the age of one year; in less developed parts of the world patients are likely to be older at the time of presentation. The mainstay of treatment is removal of the cataract and then occlusion of the better-seeing eye, but regimens vary, can be difficult to execute, and traditionally are believed to lead to disappointing results. Objectives Our objective was to evaluate the effectiveness of occlusion therapy for SDA in an attempt to establish realistic treatment outcomes. Where data were available, we also planned to examine evidence of any dose response effect and to assess the effect of the duration, severity, and causative factor on the size and direction of the treatment effect. Search methods We searched CENTRAL (which contains the Cochrane Eyes and Vision Group Trials Register) (The Cochrane Library 2013, Issue 9), Ovid MEDLINE, Ovid MEDLINE In-Process and Other Non-Indexed Citations, Ovid MEDLINE Daily, Ovid OLDMEDLINE (January 1946 to October 2013), EMBASE (January 1980 to October 2013), the Latin American and Caribbean Literature on Health Sciences (LILACS) (January 1982 to October 2013), PubMed (January 1946 to October 2013), the metaRegister of Controlled Trials (mRCT) (www.controlled-trials.com), ClinicalTrials.gov (www.clinicaltrials.gov) and the WHO International Clinical Trials Registry Platform (ICTRP) (www.who.int/ictrp/search/en). We did not use any date or language restrictions in the electronic searches for trials. We last searched the electronic databases on 28 October 2013. Selection criteria We planned

  9. Occlusion of an Intraosseous Arteriovenous Malformation With Percutaneous Injection of Polymethylmethacrylate

    SciTech Connect

    Ierardi, Anna Maria; Mangini, Monica; Vaghi, Massimo; Cazzulani, Alberto; Mattassi, Raul; Carrafiello, Gianpaolo

    2011-02-15

    Primary intraosseous arteriovenous malformations are rare. Many minimally invasive procedures can be considered preoperative steps and/or definitive treatment. The case reported regards a young woman with a voluminous arteriovenous extratroncular infiltrating malformation of the humerus. She underwent several treatments, but none of them was completely occlusive. The last treatment consisted of direct percutaneous puncture of the intraosseous alteration and injection of polymethylmethacrylate (PMMA), which is normally used in percutaneous vertebroplasty. We obtained complete occlusion of the humerus lytic lesion. To the best of our knowledge, this represents the first case of intraosseous AVM treated by percutaneous injection of PMMA.

  10. Endovascular Therapeutic Approaches for Acute Superior Mesenteric Artery Occlusion

    SciTech Connect

    Acosta, S. Sonesson, B.; Resch, T.

    2009-09-15

    The purpose of this study was to characterize the outcome of attempted endovascular intervention in patients with acute embolic or thrombotic superior mesenteric artery (SMA) occlusion. The records of 21 patients during a 3-year period between 2005 and 2008 were retrieved from the in-hospital registry. The first group included 10 patients (6 women and 4 men; median age 78 years) with acute embolic occlusion of the SMA. The median duration of symptoms from symptom onset to angiography was 30 hours (range 6 to 120). Synchronous emboli (n = 12) occurred in 6 patients. Embolus aspiration was performed in 9 patients, and 7 of these had satisfactory results. Complementary local thrombolysis was successful in 2 of 3 patients. Residual emboli were present at completion angiography in all 7 patients who underwent successful aspiration embolectomy, and bowel resection was necessary in only 1 of these patients. One serious complication occurred because of a long SMA dissection. The in-hospital survival rate was 90% (9 of 10 patients). The second group included 11 patients (10 women and 1 man; median age 68 years) with atherosclerotic acute SMA occlusions. The median time of symptom duration before intervention was 97 hours (range 17 to 384). The brachial, femoral, and SMA routes were used in 6, 7, and 5 patients, respectively. SMA stenting was performed through an antegrade (n = 7) or retrograde (n = 3) approach. Bowel resection was necessary in 4 patients. No major complications occurred. The in-hospital survival rate was 82% (9 of 11 patients). Endovascular therapy of acute SMA occlusion provides a good alternative to open surgery.

  11. Workflow Optimization in Vertebrobasilar Occlusion

    SciTech Connect

    Kamper, Lars Meyn, Hannes; Nordmeyer, Simone; Kempkes, Udo; Piroth, Werner

    2012-06-15

    Objective: In vertebrobasilar occlusion, rapid recanalization is the only substantial means to improve the prognosis. We introduced a standard operating procedure (SOP) for interventional therapy to analyze the effects on interdisciplinary time management. Methods: Intrahospital time periods between hospital admission and neuroradiological intervention were retrospectively analyzed, together with the patients' outcome, before (n = 18) and after (n = 20) implementation of the SOP. Results: After implementation of the SOP, we observed statistically significant improvement of postinterventional patient neurological status (p = 0.017). In addition, we found a decrease of 5:33 h for the mean time period from hospital admission until neuroradiological intervention. The recanalization rate increased from 72.2% to 80% after implementation of the SOP. Conclusion: Our results underscore the relevance of SOP implementation and analysis of time management for clinical workflow optimization. Both may trigger awareness for the need of efficient interdisciplinary time management. This could be an explanation for the decreased time periods and improved postinterventional patient status after SOP implementation.

  12. Pulmonary veno-occlusive disease.

    PubMed

    Montani, David; Lau, Edmund M; Dorfmüller, Peter; Girerd, Barbara; Jaïs, Xavier; Savale, Laurent; Perros, Frederic; Nossent, Esther; Garcia, Gilles; Parent, Florence; Fadel, Elie; Soubrier, Florent; Sitbon, Olivier; Simonneau, Gérald; Humbert, Marc

    2016-05-01

    Pulmonary veno-occlusive disease (PVOD) is a rare form of pulmonary hypertension (PH) characterised by preferential remodelling of the pulmonary venules. In the current PH classification, PVOD and pulmonary capillary haemangiomatosis (PCH) are considered to be a common entity and represent varied expressions of the same disease. The recent discovery of biallelic mutations in the EIF2AK4 gene as the cause of heritable PVOD/PCH represents a major milestone in our understanding of the molecular pathogenesis of PVOD. Although PVOD and pulmonary arterial hypertension (PAH) share a similar clinical presentation, with features of severe precapillary PH, it is important to differentiate these two conditions as PVOD carries a worse prognosis and life-threatening pulmonary oedema may occur following the initiation of PAH therapy. An accurate diagnosis of PVOD based on noninvasive investigations is possible utilising oxygen parameters, low diffusing capacity for carbon monoxide and characteristic signs on high-resolution computed tomography of the chest. No evidence-based medical therapy exists for PVOD at present and lung transplantation remains the preferred definitive therapy for eligible patients. PMID:27009171

  13. Non-occlusive mesenteric ischemia.

    PubMed

    Lock, G; Schölmerich, J

    1995-07-01

    Non-occlusive disease of the mesentery is still a rather underdiagnosed and underestimated condition. It is associated with circumstances that may compromise circulation or the intake of drugs that may lower mesenteric blood flow. Pathophysiologically, a "low flow syndrome" of mesenteric circulation is followed by vasoconstriction; a reperfusion injury may contribute to the ischemic injury. Histopathological changes vary between superficial localized lesions and transmural gangrene. Diagnosis within the initial 24 hours of the development of symptoms is crucial for prognosis but remains a difficult task. Clinical presentation, laboratory tests and ultrasound lack specificity; the role of duplex ultrasound, tonometry and reflectance spectophotometry is still under evaluation. Mesenteric angiography remains the only reliable diagnostic tool and should be applied early in all patients in whom acute mesenteric ischemia is a real possibility. Therapy is aimed at the rapid correction of predisposing and precipitating factors and an effective treatment of mesenteric vasoconstriction. Treatment of choice is a papaverine infusion into the superior mesenteric artery via an angiography catheter. Patients with peritoneal signs have to be treated surgically. PMID:7590571

  14. Implications of Natural Occlusion of Ventilated Racks on Ammonia and Sanitation Practices

    PubMed Central

    Creamer, Michelle A; Petty, Joann; Martin, Tara; Bergdall, Valerie; Hickman-Davis, Judy M

    2014-01-01

    Examination of ventilated rat racks prior to semiannual sanitation revealed silicone nozzles and ventilation ports that were partially or completely occluded with granular debris. We subsequently sought to document performance standards for rack sanitation and investigate the effect of ventilation port occlusion on rack function and animal husbandry practices. We hypothesized that individually ventilated cages with occluded airflow would require more frequent cage changes, comparable to those for static cages (that is, every 3 to 4 d). Sprague–Dawley rats were housed under one of 4 conditions: no airflow occlusion, occluded air-supply inlet, occluded air-exhaust outlet, and occlusion of both inlet and outlet. Cages were changed when daily ammonia concentration exceeded 20 ppm or after 14 d had elapsed. Most cages with unoccluded or partial airflow occlusion remained below the 20 ppm limit until day 12 or 13. Cages with occlusion of both inlet and outlet exceeded 20 ppm ammonia by as early as day 5. Airflow was significantly lower in cages with occlusion of both inlet and outlet airflow. Weekly inspection revealed that occlusion of ventilation ports was detectable by 3 mo after semiannual sanitation. This study demonstrates that silicone nozzles should be removed prior to rack sanitation to improve the effectiveness of cleaning ventilation ports and nozzles. While the rack is in use, silicone nozzles and ventilation ports should be inspected regularly to identify occlusion that is likely to diminish environmental quality in the cage. Intracage ammonia levels are significantly higher when both inlet and outlet airflow are occluded. PMID:24602544

  15. Retinal vein occlusion: pathophysiology and treatment options

    PubMed Central

    Karia, Niral

    2010-01-01

    This paper reviews the current thinking about retinal vein occlusion. It gives an overview of its pathophysiology and discusses the evidence behind the various established and emerging treatment paradigms. PMID:20689798

  16. Conventional occlusion versus pharmacologic penalization for amblyopia

    PubMed Central

    Li, Tianjing; Shotton, Kate

    2013-01-01

    Background Amblyopia is defined as defective visual acuity in one or both eyes without demonstrable abnormality of the visual pathway, and is not immediately resolved by wearing glasses. Objectives To assess the effectiveness and safety of conventional occlusion versus atropine penalization for amblyopia. Search methods We searched CENTRAL, MEDLINE, EMBASE, LILACS, the WHO International Clinical Trials Registry Platform, preference lists, science citation index and ongoing trials up to June 2009. Selection criteria We included randomized/quasi-randomized controlled trials comparing conventional occlusion to atropine penalization for amblyopia. Data collection and analysis Two authors independently screened abstracts and full text articles, abstracted data, and assessed the risk of bias. Main results Three trials with a total of 525 amblyopic eyes were included. One trial was assessed as having a low risk of bias among these three trials, and one was assessed as having a high risk of bias. Evidence from three trials suggests atropine penalization is as effective as conventional occlusion. One trial found similar improvement in vision at six and 24 months. At six months, visual acuity in the amblyopic eye improved from baseline 3.16 lines in the occlusion and 2.84 lines in the atropine group (mean difference 0.034 logMAR; 95% confidence interval (CI) 0.005 to 0.064 logMAR). At 24 months, additional improvement was seen in both groups; but there continued to be no meaningful difference (mean difference 0.01 logMAR; 95% CI −0.02 to 0.04 logMAR). The second trial reported atropine to be more effective than occlusion. At six months, visual acuity improved 1.8 lines in the patching group and 3.4 lines in the atropine penalization group, and was in favor of atropine (mean difference −0.16 logMAR; 95% CI −0.23 to −0.09 logMAR). Different occlusion modalities were used in these two trials. The third trial had inherent methodological flaws and limited inference could

  17. Stenting in Acute Lower Limb Arterial Occlusions

    SciTech Connect

    Raja, Jowad; Munneke, Graham; Morgan, Robert; Belli, Anna-Maria

    2008-07-15

    Management of critical limb ischemia of acute onset includes surgical embolectomy, bypass grafting, aspiration thrombectomy, thrombolysis, and mechanical thrombectomy followed by treatment of the underlying cause. We present our experience with the use of stents to treat acute embolic/thrombotic occlusions in one iliac and three femoropopliteal arteries. Although this is a small case series, excellent immediate and midterm results suggest that stenting of acute occlusions of the iliac, superficial femoral, and popliteal arteries is a safe and effective treatment option.

  18. A mechanistic approach to blood flow occlusion.

    PubMed

    Loenneke, J P; Wilson, G J; Wilson, J M

    2010-01-01

    Low-Intensity occlusion training provides a unique beneficial training mode for promoting muscle hypertrophy. Training at intensities as low as 20% 1RM with moderate vascular occlusion results in muscle hypertrophy in as little as three weeks. The primary mechanisms by which occlusion training is thought to stimulate growth include, metabolic accumulation, which stimulates a subsequent increase in anabolic growth factors, fast-twitch fiber recruitment (FT), and increased protein synthesis through the mammalian target of rapamycin (mTOR) pathway. Heat shock proteins, Nitric oxide synthase-1 (NOS-1) and Myostatin have also been shown to be affected by an occlusion stimulus. In conclusion, low-intensity occlusion training appears to work through a variety of mechanisms. The research behind these mechanisms is incomplete thus far, and requires further examination, primarily to identify the actual metabolite responsible for the increase in GH with occlusion, and determine which mechanisms are associated to a greater degree with the hypertrophic/anti-catabolic changes seen with blood flow restriction. PMID:19885776

  19. Dangerous Pressurization and Inappropriate Alarms during Water Occlusion of the Expiratory Circuit of Commonly Used Infant Ventilators

    PubMed Central

    Perdomo, Aldo

    2016-01-01

    Background Non-invasive continuous positive airways pressure is commonly a primary respiratory therapy delivered via multi-purpose ventilators in premature newborns. Expiratory limb occlusion due to water accumulation or ‘rainout’ from gas humidification is a frequent issue. A case of expiratory limb occlusion due to rainout causing unexpected and excessive repetitive airway pressurisation in a Draeger VN500 prompted a systematic bench test examination of currently available ventilators. Objective To assess neonatal ventilator response to partial or complete expiratory limb occlusion when set to non-invasive continuous positive airway pressure mode. Design Seven commercially available neonatal ventilators connected to a test lung using a standard infant humidifier circuit with partial and/or complete expiratory limb occlusion were examined in a bench test study. Each ventilator was set to deliver 6 cmH2O in non-invasive mode and respiratory mechanics data for 75%, 80% and 100% occlusion were collected. Results Several ventilators responded inappropriately with complete occlusion by cyclical pressurisation/depressurisation to peak pressures of between 19·4 and 64·6 cm H2O at rates varying between 2 to 77 inflations per minute. Tidal volumes varied between 10·1 and 24·3mL. Alarm responses varied from ‘specific’ (tube occluded) to ‘ambiguous’ (Safety valve open). Carefusion Avea responded by continuing to provide the set distending pressure and displaying an appropriate alarm message. Draeger Babylog 8000 did not alarm with partial occlusions and incorrectly displayed airways pressure at 6·1cmH2O compared to the measured values of 13cmH2O. Conclusions This study found a potential for significant adverse ventilator response due to complete or near complete expiratory limb occlusion in CPAP mode. PMID:27116224

  20. Treatment of a unilateral complete lingual crossbite in an adult with skeletal anchorage assisted orthodontics.

    PubMed

    Krishnaswamy, Nathamuni Rengarajan; Varghese, Biju Tom; Ahmed, Kasim Shakeel; Bharadwaj, Rekha; Devi, V R Shobbana

    2016-09-01

    An asymmetry caused by a complete lingual crossbite can compromise aesthetics and impair occlusal function. The following case report describes the correction of a complete lingual crossbite using orthodontic mini implants and mini-plates to achieve absolute anchorage. A comprehensive correction of the crossbite and re-establishment of the buccal occlusion was achieved. PMID:26777996

  1. Precision metal occlusal surfaces for removable partial dentures.

    PubMed

    Barco, M T; Synnott, S A

    1989-01-01

    The prosthodontist is often limited in developing the desired occlusal pattern when integrating removable partial dentures with natural dentitions or fixed partial dentures. A technique that allows the development of an esthetic, accurate metal occlusal surface for a removable partial denture is described. The occlusion developed allows an occlusal harmony with the removable partial denture that is not possible with stock denture teeth or metal occlusal surfaces developed with stock denture teeth. PMID:2700630

  2. Analysis of Hemodynamics and Aneurysm Occlusion after Flow Diverting Treatment in Rabbit Models

    PubMed Central

    Cebral, Juan R.; Mut, Fernando; Raschi, Marcelo; Hodis, Simona; Ding, Yong-Hong; Erickson, Bradley J.; Kadirvel, Ramanathan; Kallmes, David F.

    2015-01-01

    Purpose to investigate the relationship between hemodynamic conditions created immediately after flow diversion and subsequent occlusion of experimental aneurysms in rabbits. Methods The hemodynamic environment before and after flow diversion treatment of elastase induced aneurysms in 20 rabbits was modeled using image-based computational fluid dynamics. Local aneurysm occlusion was quantified using a voxelization technique on 3D images acquired 8 weeks after treatment. Global and local voxel-by-voxel hemodynamic variables were used to statistically compare aneurysm regions that later thrombosed to regions that remained patent. Results Six aneurysms remained patent at 8 weeks while 14 were completely or nearly completely occluded. Patent aneurysms had statistically larger neck sizes (p=0.0015) and smaller mean transit times (p=0.02). The velocity, vorticity and shear rate were about 2.8 times (p<0.0001) larger in patent regions, i.e. had larger “flow activity”, than regions that progressed to occlusion. Statistical models based on local hemodynamic variables were capable of predicting local occlusion with good precision (84% accuracy), especially away from the neck (92–94%). Predictions near the neck were poorer (73% accuracy). Conclusion These results suggests that the dominant healing mechanism of occlusion within the aneurysm dome are related to slow flow induced thrombosis while near the neck other processes could be at play simultaneously. PMID:24729467

  3. Analysis of Hemodynamics and Aneurysm Occlusion after Flow Diverting Treatment in Rabbit Models

    PubMed Central

    Cebral, Juan R.; Mut, Fernando; Raschi, Marcelo; Hodis, Simona; Ding, Yong-Hong; Erickson, Bradley J.; Kadirvel, Ramanathan; Kallmes, David F.

    2014-01-01

    Purpose to investigate the relationship between hemodynamic conditions created immediately after flow diversion and subsequent occlusion of experimental aneurysms in rabbits. Methods The hemodynamic environment before and after flow diversion treatment of elastase induced aneurysms in 20 rabbits was modeled using image-based computational fluid dynamics. Local aneurysm occlusion was quantified using a voxelization technique on 3D images acquired 8 weeks after treatment. Global and local voxel-by-voxel hemodynamic variables were used to statistically compare aneurysm regions that later thrombosed to regions that remained patent. Results Six aneurysms remained patent at 8 weeks while 14 were completely or nearly completely occluded. Patent aneurysms had statistically larger neck sizes (p=0.0015) and smaller mean transit times (p=0.02). The velocity, vorticity and shear rate were about 2.8 times (p<0.0001) larger in patent regions, i.e. had larger “flow activity”, than regions that progressed to occlusion. Statistical models based on local hemodynamic variables were capable of predicting local occlusion with good precision (84% accuracy), especially away from the neck (92–94%). Predictions near the neck were poorer (73% accuracy). Conclusion These results suggests that the dominant healing mechanism of occlusion within the aneurysm dome are related to slow flow induced thrombosis while near the neck other processes could be at play simultaneously. PMID:24722302

  4. Endovascular Treatment Strategies in Aortoiliac Occlusion

    SciTech Connect

    Ozkan, Ugur Oguzkurt, Levent Tercan, Fahri Gumus, Burcak

    2009-05-15

    The aim of this study was to report our experience in endovascular treatment of total aortoiliac occlusion. Five patients who underwent endovascular recanalization procedures including manual aspiration thrombectomy, balloon angioplasty, and stent placement for total aortoiliac occlusion in a 4-year period were reviewed retrospectively. The mean age of patients was 51 years (range, 43 to 58 years). All patients had abdominal aorta and bilateral common iliac artery occlusion with or without external iliac artery occlusion. All patients either had a contraindication to surgery or refused it. Initial technical success was obtained in four of five (80%) patients. Endovascular techniques were successful in four patients who had good distal runoff and short-segment aortoiliac occlusion, but failed in a patient who had the worst distal runoff and long-segment aortoiliac occlusion. We observed two major complications, one of which was bilateral rupture of the common iliac arteries treated with covered stent placement. Another patient had extension of intra-aortic thrombus into the iliac stent after primary stenting. This was successfully treated with manual aspiration thrombectomy. Aortic and iliac stents remained patent during the follow-up period (median, 18 months; range, 3 to 26 months) in four patients. Primary patency rates at 6, 12, and 24 months were all 80%. In conclusion, endovascular treatment can be an alternative for aortoiliac occlusion in selected patients. Short- to midterm follow-up so far is satisfactory. Removal of intra-aortic thrombus with manual aspiration thrombectomy before balloon angioplasty and/or stenting is possible and a good alternative to thrombolysis.

  5. Transcatheter closure of modified Blalock-Taussig shunt with Gianturco-Grifka Vascular Occlusion Device.

    PubMed

    Hoyer, M H; Leon, R A; Fricker, F J

    1999-12-01

    A 15-year-old girl with previous repair of a complex cyanotic congenital heart defect had persistence of a modified left Blalock-Taussig shunt that could not be ligated at surgery. Six years later, antegrade delivery of a Gianturco-Grifka Vascular Occlusion Device resulted in complete closure of the shunt. Cathet. Cardiovasc. Intervent. 48:365-367, 1999. PMID:10559814

  6. Local low dose streptokinase in the treatment of acute peripheral arterial occlusion.

    PubMed

    Breslau, P J; Van der Linden, C J; Janevski, B; Jörning, P J

    1984-06-01

    Case report of local low dose streptokinase therapy in a patient with acute occlusion of the left branch of an aortobifurcation graft. Objective evidence of complete thrombolysis was demonstrated both by arteriography and hemodynamic parameters. In carefully selected cases this thrombolytic therapy is a promising alternative to surgery. PMID:6738887

  7. Primary Stenting in Infrarenal Aortic Occlusive Disease

    SciTech Connect

    Nyman, Ulf; Uher, Petr; Lindh, Mats; Lindblad, Bengt; Ivancev, Krasnodar

    2000-03-15

    Purpose: To evaluate the results of primary stenting in aortic occlusive disease.Methods: Thirty patients underwent primary stenting of focal concentric (n = 2) and complex aortic stenoses (n = 19), and aortic or aorto-iliac occlusions (n = 9). Sixteen patients underwent endovascular outflow procedures, three of whom also had distal open surgical reconstructions. Median follow-up was 16 months (range 1-60 months).Results: Guidewire crossing of two aorto-biiliac occlusions failed, resulting in a 93% (28/30) technical success. Major complications included one access hematoma, one myocardial infarction, one death (recurrent thromboembolism) in a patient with widespread malignancy, and one fatal hemorrhage during thrombolysis of distal emboli from a recanalized occluded iliac artery. One patient did not improve his symptoms, resulting in a 1-month clinical success of 83% (25/30). Following restenting the 26 stented survivors changed their clinical limb status to +3 (n = 17) and +2 (n = 9). During follow-up one symptomatic aortic restenosis occurred and was successfully restented.Conclusions: Primary stenting of complex aortic stenoses and short occlusions is an attractive alternative to conventional surgery. Larger studies with longer follow-up and stratification of lesion morphology are warranted to define its role relative to balloon angioplasty. Stenting of aorto-biiliac occlusions is feasible but its role relative to bypass grafting remains to be defined.

  8. Progression of Diabetic Capillary Occlusion: A Model

    PubMed Central

    Gens, John Scott; Glazier, James A.; Burns, Stephen A.; Gast, Thomas J.

    2016-01-01

    An explanatory computational model is developed of the contiguous areas of retinal capillary loss which play a large role in diabetic maculapathy and diabetic retinal neovascularization. Strictly random leukocyte mediated capillary occlusion cannot explain the occurrence of large contiguous areas of retinal ischemia. Therefore occlusion of an individual capillary must increase the probability of occlusion of surrounding capillaries. A retinal perifoveal vascular sector as well as a peripheral retinal capillary network and a deleted hexagonal capillary network are modelled using Compucell3D. The perifoveal modelling produces a pattern of spreading capillary loss with associated macular edema. In the peripheral network, spreading ischemia results from the progressive loss of the ladder capillaries which connect peripheral arterioles and venules. System blood flow was elevated in the macular model before a later reduction in flow in cases with progression of capillary occlusions. Simulations differing only in initial vascular network structures but with identical dynamics for oxygen, growth factors and vascular occlusions, replicate key clinical observations of ischemia and macular edema in the posterior pole and ischemia in the retinal periphery. The simulation results also seem consistent with quantitative data on macular blood flow and qualitative data on venous oxygenation. One computational model applied to distinct capillary networks in different retinal regions yielded results comparable to clinical observations in those regions. PMID:27300722

  9. Neuromuscular dentistry: Occlusal diseases and posture.

    PubMed

    Khan, Mohd Toseef; Verma, Sanjeev Kumar; Maheshwari, Sandhya; Zahid, Syed Naved; Chaudhary, Prabhat K

    2013-01-01

    Neuromuscular dentistry has been a controversial topic in the field of dentistry and still remains debatable. The issue of good occlusion and sound health has been repeatedly discussed. Sometimes we get complains of sensitive teeth and sometimes of tired facial muscles on getting up in the morning. Owing to the intimate relation of masticatory apparatus with the cranium and cervico-scapular muscular system, the disorders in any system, draw attention from concerned clinicians involved in management, to develop an integrated treatment protocol for the suffering patients. There may be patients reporting to the dental clinics after an occlusal restoration or extraction, having pain in or around the temporomandibular joint, headache or neck pain. Although their esthetic demands must not be undermined during the course of treatment plan, whenever dental treatment of any sort is planned, occlusion/bite should be given prime importance. Very few dentist are able to diagnose the occlusal disease and of those who diagnose many people resort to aggressive treatment modalities. This paper aims to report the signs of occlusal disease, and discuss their association with TMDs and posture. PMID:25737904

  10. Evaluation of the contribution of red and white cells to the flow of suspensions of washed blood cells through 3 micron Nuclepore membranes.

    PubMed

    Jones, J G; Holland, B M; Humphrys, J; Quew, R; Wardrop, C A

    1984-07-01

    This study was designed to investigate a method of analysis which can quantitate the contribution of white cells to the flow of washed suspensions of blood cells. Such an analysis would obviate the need to remove white cells when studying the filterability of normal and abnormal red cells. The flow of suspensions of washed blood cells through a 3 micron Nuclepore membrane declines continually due to the occlusion of pores and the degree of pore occlusion is reduced significantly by the removal of the 'buffy coat' during the preparation of the suspension. These findings are in complete agreement with many other reports. However, a detailed kinetic analysis of the results suggests strongly that the white cell population makes a small contribution to the degree of pore occlusion which is caused largely by approximately 1% of the total red cell population. Despite the phenomenon and extent of pore occlusion, a kinetic analysis of the complete non-linear flow profile allows a measure of the deformability of red cells from filtration studies of washed but unfractionated blood cells. PMID:6743566

  11. A case of veno-occlusive disease following liver transplantation

    PubMed Central

    CHEN, HONG; WANG, XU; FAN, TIEYAN; LI, JUN; WANG, LETIAN; SHEN, ZHONGYANG

    2014-01-01

    The present case report describes the diagnosis and treatment of a patient with veno-occlusive disease (VOD) following liver transplantation. Combining the clinical data and relevant literature, the study aimed to consider the causes of VOD following liver transplantation, and the pathogenesis, clinical diagnosis and auxiliary examination features of VOD. A 42-year-old man who had a long history of taking traditional Chinese medicine (essential components unknown) underwent an orthotropic liver transplantation on January 14, 2011, due to small venous occlusion disease of the liver. The patient was treated with tacrolimus as an antirejection therapy following the surgery, and gradually developed right upper quadrant pain and fatigue. The examination results were consistent with the diagnostic standards for VOD. Following treatment with methylprednisolone, the patient was treated with alprostadil and Danhong injections. Forty days later, the patient’s total bilirubin (TBIL) level was observed to have decreased significantly, the liver function had returned to normal and the ascites had decreased, but had not completely disappeared. The patient then underwent a transjugular intrahepatic portosystemic shunt (TIPS) procedure, following which the ascites were shown to have completely disappeared. PMID:24348779

  12. Endovascular Treatment of Venous Occlusive Disease

    PubMed Central

    2008-01-01

    Endovascular treatment of acute and chronic iliac vein occlusions has proven to be safe and effective. Recanalization of chronic occlusions with balloon angioplasty and stenting can re-establish normal venous flow in the iliac veins and the IVC and relieve symptoms in the majority of treated patients. CDT with recanalization and stenting of underlying chronically obstructed iliofemoral segments is becoming the treatment of choice for patients with acute iliofemoral thrombosis, as anticoagulation and compression therapy alone are not satisfactory in preventing PTS. The new treatment modalities offer stimulating options for a patient group that is not adequately treated, neither by medical nor open surgical therapy. The substantial effort and additional costs of endovascular treatment appear to be justified by the encouraging mid-term results both for patients with acute and chronic occlusive iliofemoral disease. However, multi-center randomized prospective studies are required to further validate the role of these techniques. PMID:23555345

  13. [Retinal vein occlusion: an interdisciplinary approach].

    PubMed

    Hatz, Katja; Martinez, Maria

    2016-01-01

    Retinal vein occlusion provide a common cause of significant visual reduction but also late ocular complications. The medical care of these patients pursue two goals: On the one hand vision threatening complications need to be identified and treated, and on the other hand treatable risk factors are need to be identified and treated. This paper summarizes the common ophthalmological therapeutic approaches as well as recommended medical evaluations carried out by the general practitioner. This supports the interdisciplinary approach in evaluating and treating retinal vein occlusions by ophthalmologists and the general practitioners/specialist in internal medicine. PMID:26982647

  14. Occlusal Characteristics of the Primary Dentition Revisited.

    PubMed

    Alexander, Stanley A; Askari, Marjan; Lewis, Patricia

    2015-11-01

    The occlusal characteristics of the primary dentition of 130 children 3 to 6 years old were examined. Variables were the terminal plane relationship, primary canine occlusion, spacing, overjet and overbite relationships. The flush terminal plane was the most common finding. A Class I relationship of the primary canine occurred in 85% of the subjects. Spaced dentitions occurred 81% of the time, while the presence of primate spaces occurred in at least one of the four quadrants. The overjet relationship varied from +1 mm to 4 mm in all subjects, and the majority of children were considered to have a normal overbite. PMID:26749782

  15. Temporary Arterial Balloon Occlusion as an Adjunct to Yttrium-90 Radioembolization

    SciTech Connect

    Hagspiel, Klaus D.; Nambiar, Ashwin; Hagspiel, Lauren M.; Ahmad, Ehab Ali; Bozlar, Ugur

    2013-06-15

    Purpose. This study was designed to describe the technique of arterial occlusion using a temporary occlusion balloon system as an alternative to coil occlusion during Yttrium-90 radioembolization of hepatic tumors. Methods. Review of charts, angiography, and follow-up imaging studies of consecutive patients undergoing oncological embolization procedures in which a HyperForm system (ev3 Neurovascular, Irvine, CA) was used. Intraprocedural target vessel occlusion and patency of the target vessel on follow-up were recorded. Clinical data and Bremsstrahlung scans were reviewed for evidence of nontarget embolization. Results. Four radioembolization procedures were performed in three patients (all female, age 48-54 (mean 52) years). Five arteries were temporarily occluded (three gastroduodenal arteries, one right gastric artery, and one cystic artery). All radioembolization procedures were successfully completed. Follow-up imaging (either digital subtraction angiography (DSA) or computed tomography angiography (CTA)) was available for all patients between 28-454 (mean 183) days following the procedure, demonstrating all five vessels to be patent. No clinical or imaging evidence for nontarget embolization was found. Conclusions. Temporary balloon occlusion of small and medium-sized arteries during radioembolization allows safe therapy with preserved postprocedural vessel patency on early and midterm follow-up.

  16. Remote-controlled stop of phloem mass flow by biphasic occlusion in Cucurbita maxima

    PubMed Central

    Furch, Alexandra C. U.; Zimmermann, Matthias R.; Will, Torsten; Hafke, Jens B.; van Bel, Aart J. E.

    2010-01-01

    The relationships between damage-induced electropotential waves (EPWs), sieve tube occlusion, and stop of mass flow were investigated in intact Cucurbita maxima plants. After burning leaf tips, EPWs propagating along the phloem of the main vein were recorded by extra- and intracellular microelectrodes. The respective EPW profiles (a steep hyperpolarization/depolarization peak followed by a prolonged hyperpolarization/depolarization) probably reflect merged action and variation potentials. A few minutes after passage of the first EPW peak, sieve tubes gradually became occluded by callose, with maximum synthesis occurring ∼10 min after burning. Early stop of mass flow, well before completion of callose deposition, pointed to an occlusion mechanism preceding callose deposition. This obstruction of mass flow was inferred from the halt of carboxyfluorescein movement in sieve tubes and intensified secretion of aqueous saliva by feeding aphids. The early occlusion is probably due to proteins, as indicated by a dramatic drop in soluble sieve element proteins and a simultaneous coagulation of sieve element proteins shortly after the burning stimulus. Mass flow resumed 30–40 min after burning, as demonstrated by carboxyfluorescein movement and aphid activities. Stop of mass flow by Ca2+-dependent occlusion mechanisms is attributed to Ca2+ influx during EPW passage; the reversibility of the occlusion is explained by removal of Ca2+ ions. PMID:20584788

  17. Suprarenal fixation barbs can induce renal artery occlusion in endovascular aortic aneurysm repair.

    PubMed

    Subedi, Shree K; Lee, Andy M; Landis, Gregg S

    2010-01-01

    Renal artery occlusion following endovascular abdominal aortic aneurysm repair with suprarenal fixation is uncommon. We report one patient who was found to develop renal artery occlusion and parenchymal infarction 6 months after repair using an endovascular graft with suprarenal fixation. Our patient underwent emergent endovascular repair of a symptomatic 6 cm abdominal aortic aneurysm. The covered portion of the endograft was inadvertently deployed well below the renal artery orifices. At the completion of the procedure both renal arteries were confirmed to be patent. One month postoperatively, a computed tomographic (CT) scan showed exclusion of the aortic sac and normal enhancement of both kidneys. At 6 months, the patient was found to have elevated serum creatinine levels despite having no clinical symptoms. CT scanning revealed a nonenhancing left kidney, and angiography demonstrated an occlusion of the left renal artery. A barb welded to the bare metal stent appeared to be impinging on the renal artery. We believe that renal artery occlusion after endovascular repair can occur due to repetitive injury to the renal artery orifice from barbs welded to the bare metal stent. To our knowledge, this is the first reported case of renal artery occlusion caused by repetitive injury from transrenal fixation systems. PMID:19540715

  18. Immediate occlusal loading for fixed prostheses in implant dentistry.

    PubMed

    Misch, Carl E; Wang, Hom-Lay

    2003-08-01

    The majority of clinical reports reveal similar survival rates between immediate-loaded and 2-stage-unloaded healing approaches in the completely edentulous patient. In our prospective study, 31 arches received immediate-loaded restorations in 30 patients, supported by 244 implants. All implants were followed a minimum of 2 years after prosthesis delivery to as long as 6 years. The implant and final prosthesis survival were 100% during this time frame. Nonetheless, these findings do not imply a submerged surgical approach is no longer necessary or prudent in many cases. Future studies may find indications based upon surgical, host, implant, and occlusal-related conditions more beneficial for one versus the other. The strength of bone and the modulus of elasticity are both directly related to bone density. The softest bone type may be 10 times weaker than the most dense types. The microstrain mismatch of titanium and the softest bone is much greater than with the densest bone. As a consequence, higher implant failure and greater crestal bone loss seem likely but as yet has not been reported in the literature. A biomechanical treatment approach to increase surface area and decrease forces applied to the immediate restorations is logical to increase implant survival. Conditions that decrease strain to a developing interface include increasing implant number, implant size, and implant thread number and depth. Patient factors such as parafunction may increase forces to the implant interface, while implant position may be used to decrease forces, especially when a splinted arch form is created. Tables 3 and 4 list guidelines for immediate occlusal loading. As a general principle, the clinical should be able to increase surface area while minimizing occlusal force to ensure long-term success. PMID:14515575

  19. Ear recognition: a complete system

    NASA Astrophysics Data System (ADS)

    Abaza, Ayman; Harrison, Mary Ann F.

    2013-05-01

    Ear Recognition has recently received significant attention in the literature. Even though current ear recognition systems have reached a certain level of maturity, their success is still limited. This paper presents an efficient complete ear-based biometric system that can process five frames/sec; Hence it can be used for surveillance applications. The ear detection is achieved using Haar features arranged in a cascaded Adaboost classifier. The feature extraction is based on dividing the ear image into several blocks from which Local Binary Pattern feature distributions are extracted. These feature distributions are then fused at the feature level to represent the original ear texture in the classification stage. The contribution of this paper is three fold: (i) Applying a new technique for ear feature extraction, and studying various optimization parameters for that technique; (ii) Presenting a practical ear recognition system and a detailed analysis about error propagation in that system; (iii) Studying the occlusion effect of several ear parts. Detailed experiments show that the proposed ear recognition system achieved better performance (94:34%) compared to other shape-based systems as Scale-invariant feature transform (67:92%). The proposed approach can also handle efficiently hair occlusion. Experimental results show that the proposed system can achieve about (78%) rank-1 identification, even in presence of 60% occlusion.

  20. Virtual occlusal definition for orthognathic surgery.

    PubMed

    Liu, X J; Li, Q Q; Zhang, Z; Li, T T; Xie, Z; Zhang, Y

    2016-03-01

    Computer-assisted surgical simulation is being used increasingly in orthognathic surgery. However, occlusal definition is still undertaken using model surgery with subsequent digitization via surface scanning or cone beam computed tomography. A software tool has been developed and a workflow set up in order to achieve a virtual occlusal definition. The results of a validation study carried out on 60 models of normal occlusion are presented. Inter- and intra-user correlation tests were used to investigate the reproducibility of the manual setting point procedure. The errors between the virtually set positions (test) and the digitized manually set positions (gold standard) were compared. The consistency in virtual set positions performed by three individual users was investigated by one way analysis of variance test. Inter- and intra-observer correlation coefficients for manual setting points were all greater than 0.95. Overall, the median error between the test and the gold standard positions was 1.06mm. Errors did not differ among teeth (F=0.371, P>0.05). The errors were not significantly different from 1mm (P>0.05). There were no significant differences in the errors made by the three independent users (P>0.05). In conclusion, this workflow for virtual occlusal definition was found to be reliable and accurate. PMID:26701322

  1. Item type, occlusion, and gender differences in mental rotation.

    PubMed

    Doyle, Randi A; Voyer, Daniel; Lesmana, Maryani

    2016-08-01

    Two experiments were conducted to examine the role of item type in mental rotation. In each experiment, participants completed two computerized mental rotation tasks, one with blocks as stimuli and one with human figures as stimuli. The tasks were formatted either as a multiple-choice psychometric test (Experiment 1) or as a same-different type task (Experiment 2). Aside from the expected replication of a decreased effect of occlusion on women's accuracy when processing human figures compared to block figures, it was hypothesized that response times would increase when processing the complex but familiar human figures, compared to the simple but unfamiliar block figures. In Experiment 1, the results relevant to occlusion were replicated. However, the presence of a speed-accuracy trade-off suggested that participants processed human figures faster but less accurately than block figures. In Experiment 2, both men and women performed faster and more accurately when processing occluded human figures than when processing nonoccluded human figures. The effect of item type, its potential link to embodied cognition, and the role of strategy selection on gender differences in mental rotation are discussed. PMID:26325234

  2. Chronic common femoral vein occlusion secondary to endometriosis

    PubMed Central

    Ju, Mila H.; Keldahl, Mark L.; Rodriguez, Heron E.

    2016-01-01

    Venous occlusion is sometimes caused by external compression due to adjacent masses. Endometriosis, the presence of functioning endometrial tissue outside the uterine cavity, is a rare cause of venous occlusion. We report a case of chronic common femoral vein occlusion due to endomctrioma causing severe leg edema and groin pain that was treated with resection and venous bypass. PMID:26993188

  3. 21 CFR 880.5950 - Umbilical occlusion device.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Umbilical occlusion device. 880.5950 Section 880... Devices § 880.5950 Umbilical occlusion device. (a) Identification. An umbilical occlusion device is a clip, tie, tape, or other article used to close the blood vessels in the umbilical cord of a newborn...

  4. 21 CFR 880.5950 - Umbilical occlusion device.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Umbilical occlusion device. 880.5950 Section 880... Devices § 880.5950 Umbilical occlusion device. (a) Identification. An umbilical occlusion device is a clip, tie, tape, or other article used to close the blood vessels in the umbilical cord of a newborn...

  5. 21 CFR 880.5950 - Umbilical occlusion device.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Umbilical occlusion device. 880.5950 Section 880... Devices § 880.5950 Umbilical occlusion device. (a) Identification. An umbilical occlusion device is a clip, tie, tape, or other article used to close the blood vessels in the umbilical cord of a newborn...

  6. 21 CFR 880.5950 - Umbilical occlusion device.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Umbilical occlusion device. 880.5950 Section 880... Devices § 880.5950 Umbilical occlusion device. (a) Identification. An umbilical occlusion device is a clip, tie, tape, or other article used to close the blood vessels in the umbilical cord of a newborn...

  7. 21 CFR 880.5950 - Umbilical occlusion device.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Umbilical occlusion device. 880.5950 Section 880... Devices § 880.5950 Umbilical occlusion device. (a) Identification. An umbilical occlusion device is a clip, tie, tape, or other article used to close the blood vessels in the umbilical cord of a newborn...

  8. The role of "rescue saccades" in tracking objects through occlusions.

    PubMed

    Zelinsky, Gregory J; Todor, Andrei

    2010-01-01

    We hypothesize that our ability to track objects through occlusions is mediated by timely assistance from gaze in the form of "rescue saccades"-eye movements to tracked objects that are in danger of being lost due to impending occlusion. Observers tracked 2-4 target sharks (out of 9) for 20 s as they swam through a rendered 3D underwater scene. Targets were either allowed to enter into occlusions (occlusion trials) or not (no occlusion trials). Tracking accuracy with 2-3 targets was ≥ 92% regardless of target occlusion but dropped to 74% on occlusion trials with four targets (no occlusion trials remained accurate; 83%). This pattern was mirrored in the frequency of rescue saccades. Rescue saccades accompanied approximatlely 50% of the Track 2-3 target occlusions, but only 34% of the Track 4 occlusions. Their frequency also decreased with increasing distance between a target and the nearest other object, suggesting that it is the potential for target confusion that summons a rescue saccade, not occlusion itself. These findings provide evidence for a tracking system that monitors for events that might cause track loss (e.g., occlusions) and requests help from the oculomotor system to resolve these momentary crises. As the number of crises increase with the number of targets, some requests for help go unsatisfied, resulting in degraded tracking. PMID:21191133

  9. 21 CFR 878.4020 - Occlusive wound dressing.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Occlusive wound dressing. 878.4020 Section 878...) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4020 Occlusive wound dressing. (a) Identification. An occlusive wound dressing is a nonresorbable, sterile or non-sterile...

  10. 21 CFR 878.4020 - Occlusive wound dressing.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Occlusive wound dressing. 878.4020 Section 878...) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4020 Occlusive wound dressing. (a) Identification. An occlusive wound dressing is a nonresorbable, sterile or non-sterile...

  11. 21 CFR 878.4020 - Occlusive wound dressing.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Occlusive wound dressing. 878.4020 Section 878...) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4020 Occlusive wound dressing. (a) Identification. An occlusive wound dressing is a nonresorbable, sterile or non-sterile...

  12. 21 CFR 878.4020 - Occlusive wound dressing.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Occlusive wound dressing. 878.4020 Section 878...) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4020 Occlusive wound dressing. (a) Identification. An occlusive wound dressing is a nonresorbable, sterile or non-sterile...

  13. 21 CFR 878.4020 - Occlusive wound dressing.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Occlusive wound dressing. 878.4020 Section 878...) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4020 Occlusive wound dressing. (a) Identification. An occlusive wound dressing is a nonresorbable, sterile or non-sterile...

  14. Venous sinus occlusive disease: MR findings

    SciTech Connect

    Yuh, W.T.C.; Simonson, T.M.; Tali, E.T.; Fisher, D.J. ); Wang, A.M. ); Koci, T.M. ); Simon, J.H. ); Jinkins, J.R. ); Tsai, Fong )

    1994-02-01

    To study MR patterns of venous sinus occlusive disease and to relate them to the underlying pathophysiology by comparing the appearance and pathophysiologic features of venous sinus occlusive disease with those of arterial ischemic disease. The clinical data and MR examinations of 26 patients with venous sinus occlusive disease were retrospectively reviewed with special attention to mass effect, hemorrhage, and T2-weighted image abnormalities as well as to abnormal parenchymal, venous, or arterial enhancement after intravenous gadopentetate dimeglumine administration. Follow-up studies when available were evaluated for atrophy, infraction, chronic mass effect, and hemorrhage. Mass effect was present in 25 of 26 patients. Eleven of the 26 had mass effect without abnormal signal on T2-weighted images. Fifteen patients had abnormal signal on T2-weighted images, but this was much less extensive than the degree of brain swelling in all cases. No patient showed abnormal parenchymal or arterial enhancement. Abnormal venous enhancement was seen in 10 of 13 patients who had contrast-enhanced studies. Intraparenchymal hemorrhage was seen in nine patients with high signal on T2-weighted images predominantly peripheral to the hematoma in eight. Three overall MR patterns were observed in acute sinus thrombosis: (1) mass effect without associated abnormal signal on T2-weighted images, (2) mass effect with associated abnormal signal on T2-weighted images and/or ventricular dilatation that may be reversible, and (3) intraparenchymal hematoma with surrounding edema. MR findings of venus sinus occlusive disease are different from those of arterial ischemia and may reflect different underlying pathophysiology. In venous sinus occlusive disease, the breakdown of the blood-brain barrier (vasogenic edema and abnormal parenchymal enhancement) does not always occur, and brain swelling can persist up to 2 years with or without abnormal signal on T2-weighted images. 34 refs., 5 figs.

  15. PS-OCT of occlusal and interproximal caries lesions viewed from occlusal surfaces

    NASA Astrophysics Data System (ADS)

    Ngaotheppitak, Patara; Darling, Cynthia L.; Fried, Daniel; Bush, Jeff; Bell, Steve

    2006-02-01

    Previous studies have demonstrated that Polarization Sensitive Optical Coherence Tomography (PS-OCT) can be used to image early dental caries. The primary objective of this study was to compare the measured reflectivity of natural occlusal caries lesions with the relative mineral loss measured using digital microradiography. There was excellent agreement between the increase in the integrated reflectivity in the perpendicular polarization axis of the PS-OCT system and the increase in the integrated mineral loss or lesion severity for occlusal lesions. Therefore, PS-OCT is ideally suited to image natural caries lesions in the important occlusal surfaces for the assessment of the lesion severity and activity. A secondary objective was to compare the performance of a new autocorrelator-based PS-OCT system employing a novel polarization-switching probe with our polarization-maintaining fiber based PS-OCT system, both operating at 1310-nm. The new PS-OCT system produced clean images with no artifacts and achieved high penetration depth. Yet a third objective was to determine if interproximal lesions can be imaged from the occlusal surface (from above) since interproximal lesions may only be accessible in vivo from buccal or lingual surfaces or from the occlusal surface. Simulated and natural interproximal caries lesions were imaged from the occlusal surfaces as long as there was no intervening dentin.

  16. Occlusion Handling in Videos Object Tracking: A Survey

    NASA Astrophysics Data System (ADS)

    Lee, B. Y.; Liew, L. H.; Cheah, W. S.; Wang, Y. C.

    2014-02-01

    Object tracking in video has been an active research since for decades. This interest is motivated by numerous applications, such as surveillance, human-computer interaction, and sports event monitoring. Many challenges related to tracking objects still remain, this can arise due to abrupt object motion, changing appearance patterns of objects and the scene, non-rigid object structures and most significant are occlusion of tracked object be it object-to-object or object-to-scene occlusions. Generally, occlusion in object tracking occur under three situations: self-occlusion, inter-object occlusion by background scene structure. Self-occlusion occurs most frequently while tracking articulated objects when one part of the object occludes another. Inter-object occlusion occurs when two objects being tracked occlude each other whereas occlusion by the background occurs when a structure in the background occludes the tracked objects. Typically, tracking methods handle occlusion by modelling the object motion using linear and non-linear dynamic models. The derived models will be used to continuously predicting the object location when a tracked object is occluded until the object reappears. Example of these method are Kalman filtering and Particle filtering trackers. Researchers have also utilised other features to resolved occlusion, for example, silhouette projections, colour histogram and optical flow. We will present some result from a previously conducted experiment when tracking single object using Kalman filter, Particle filter and Mean Shift trackers under various occlusion situation in this paper. We will also review various other occlusion handling methods that involved using multiple cameras. In a nutshell, the goal of this paper is to discuss in detail the problem of occlusion in object tracking and review the state of the art occlusion handling methods, classify them into different categories, and identify new trends. Moreover, we discuss the important

  17. Occlusion handling in videos object tracking: A survey

    NASA Astrophysics Data System (ADS)

    Lee, B. Y.; Liew, L. H.; Cheah, W. S.; Wang, Y. C.

    2014-02-01

    Object tracking in video has been an active research for decades. This interest is motivated by numerous applications, such as surveillance, human-computer interaction, and sports event monitoring. Many challenges regarding tracking objects remain, this can arise due to abrupt object motion, changing appearance patterns of objects and the scene, non-rigid object structures and most significancly occlusion of tracked object (be it object-to-object or object-to-scene occlusions). Generally, occlusion in object tracking occurs under three situations: self-occlusion, inter-object occlusion by background scene structure. Self-occlusion most frequently arises while tracking articulated objects when one part of the object occludes another. Inter-object occlusion occurs when two objects being tracked occlude each other whereas occlusion by the background occurs when a structure in the background occludes the tracked objects. Typically, tracking methods handle occlusion by modelling the object motion using linear and non-linear dynamic models. The derived models will be used to continuously predicting the object location when a tracked object is occluded until the object reappears. Examples of these methods are Kalman filtering and Particle filtering trackers. Researchers have also utilised other features to resolved occlusion, for example, silhouette projections, colour histogram and optical flow. We will present some results from a previously conducted experiment when tracking single object using Kalman filter, Particle filter and Mean Shift trackers under various occlusion situations. We will also review various other occlusion handling methods that involved using multiple cameras. In a nutshell, the goal of this paper is to discuss in detail the problem of occlusion in object tracking and review the state of the art occlusion handling methods, classify them into different categories, and identify new trends. Moreover, we discuss the important issues related to occlusion

  18. Hyperbaric oxygen for the treatment of the rare combination of central retinal vein occlusion and cilioretinal artery occlusion.

    PubMed

    Celebi, Ali Riza Cenk; Kilavuzoglu, Ayse Ebru; Altiparmak, Ugur Emrah; Cosar, C Banu; Ozkiris, Abdullah

    2016-03-01

    A 43-year-old male presented with sudden onset of painless, blurred vision in his left eye. Dilated fundoscopic examination showed signs consistent with the diagnosis of a combination of central retinal vein occlusion (CRVO) and cilioretinal artery occlusion (CLRAO). He received daily 2-h sessions of hyperbaric oxygen treatment (HBOT), 253 kPa for 14 days. At the end of the HBOT course, the patient's left visual acuity had improved from 20/200 to 20/20. Dilated fundoscopic examination showed that the intra-retinal haemorrhages in the entire retina and the retinal whitening along the course of the CLRA seen at presentation had completely resolved. The combination of CLRAO and CRVO comprises a discrete clinical entity. Even though there are many hypotheses concerning this condition, it is most likely the result of elevated intraluminal pressure in the retinal capillaries due to CRVO that exceeds the pressure in the CLRA. HBOT may be an effective treatment for CRVO-associated CLRAO. PMID:27044464

  19. Complete primary structure of the sixth chain of human basement membrane collagen, alpha 6(IV). Isolation of the cDNAs for alpha 6(IV) and comparison with five other type IV collagen chains.

    PubMed

    Zhou, J; Ding, M; Zhao, Z; Reeders, S T

    1994-05-01

    Basement membranes were previously believed to contain five distinct type IV collagen subunits. We have recently isolated part of the cDNA for a novel type IV collagen, alpha 6(IV), and shown that COL4A6, the gene encoding this new chain, is deleted in Alport syndrome-associated leiomyomatosis (Zhou, J., Mochizuki, T., Smeets, H., Antignac, C., Laurila, P., de Paepe, A., Tryggvason, K., and Reeders, S. T. (1993) Science 261, 1167-1169). Here, we describe the entire human alpha 6(IV) cDNA and show that the gene encodes a classical type IV collagen with homology throughout its length to all the other five chains. There is a 21-residue signal peptide, a 1417-residue collagenous domain interrupted at 25 points, and a 228-residue carboxyl-terminal non-collagenous domain. When the complete primary structure of this new chain was compared with all the other known chains, it became clear that alpha 6(IV) has the most resemblance to alpha 2(IV) and alpha 4(IV). The evolution of the six chains was deduced, allowing a new classification of the type IV collagen family. The alpha 6(IV) chain is a candidate gene for X-linked Alport syndrome; knowledge of the complete structure of the chain will permit us to screen systematically for mutations in patients and to generate recombinant proteins and synthetic peptides for further study of cell-matrix interactions involving the alpha 6(IV) chain. PMID:8175748

  20. Occlusal Interferences: How Can This Concept Influence The Clinical Practice?

    PubMed Central

    Lima, Adriano Fonseca; Cavalcanti, Andrea Nóbrega; Martins, Luis Roberto Marcondes; Marchi, Giselle Maria

    2010-01-01

    This brief review discusses the role of occlusal interferences on the development and progression of temporomandibular dysfunction (TMD) and postural disorders. The eligible literature is described and critically presented to demonstrate that occlusal interferences are an important factor in the risk of TMD. Several studies have demonstrated through their findings that the use of occlusal adjustments, whether or not associated with restorative procedures, might avoid the development of articular problems in vulnerable patients. The occlusal interferences caused by restorative procedures or orthodontic treatment can cause TMDs in susceptible patients, and occlusal adjustments can be an alternative in the treatment of these TMDs. PMID:20922171

  1. Combined catheter ablation for atrial fibrillation and Watchman® left atrial appendage occlusion procedures: Five-year experience

    PubMed Central

    Phillips, Karen P.; Walker, Daniel T.; Humphries, Julie A.

    2015-01-01

    Background Patients with atrial fibrillation (AF) may benefit from undergoing concomitant interventions of left atrial catheter ablation and device occlusion of the left atrial appendage (LAA) as a two-pronged strategy for rhythm control and stroke prevention. We report on the outcome of combined procedures in a single center case series over a 5-year timeframe. Methods Ninety-eight patients with non-valvular AF and a mean CHA2DS2-VASc score 2.6±1.0 underwent either first time, or redo pulmonary vein isolation (PVI) procedures, followed by successful implant of a Watchman® device. Results All procedures were generally uncomplicated with a mean case time of 213±40 min. Complete LAA occlusion was achieved at initial implant in 92 (94%) patients. Satisfactory LAA occlusion was achieved in 100% of patients at 12 months, with a complete LAA occlusion rate of 86%. All patients discontinued oral anticoagulation. Persistent late peri-device leaks were more frequently associated with device angulation or shoulder protrusion, and were associated with a significantly lower achieved device compression of 12±3% vs. 15±5% (p<0.01) than complete occlusion. One ischemic stroke was recorded over a mean follow-up time of 802±439 days. Twelve months׳ freedom from detectable AF was achieved in 77% of patients. Conclusions Combined procedures of catheter ablation for AF and Watchman® LAA implant appear to be feasible and safe, with excellent rates of LAA occlusion achieved and an observed stroke rate of 0.5% per year during mid-term follow-up. Incomplete occlusion was associated with lower achieved device compression and was more frequently associated with suboptimal device position. PMID:27092193

  2. Dental Occlusal Changes Induce Motor Cortex Neuroplasticity.

    PubMed

    Avivi-Arber, L; Lee, J-C; Sessle, B J

    2015-12-01

    Modification to the dental occlusion may alter oral sensorimotor functions. Restorative treatments aim to restore sensorimotor functions; however, it is unclear why some patients fail to adapt to the restoration and remain with sensorimotor complaints. The face primary motor cortex (face-M1) is involved in the generation and control of orofacial movements. Altered sensory inputs or motor function can induce face-M1 neuroplasticity. We took advantage of the continuous eruption of the incisors in Sprague-Dawley rats and used intracortical microstimulation (ICMS) to map the jaw and tongue motor representations in face-M1. Specifically, we tested the hypothesis that multiple trimming of the right mandibular incisor, to keep it out of occlusal contacts for 7 d, and subsequent incisor eruption and restoration of occlusal contacts, can alter the ICMS-defined features of jaw and tongue motor representations (i.e., neuroplasticity). On days 1, 3, 5, and 7, the trim and trim-recovered groups had 1 to 2 mm of incisal trimming of the incisor; a sham trim group had buccal surface trimming with no occlusal changes; and a naive group had no treatment. Systematic mapping was performed on day 8 in the naive, trim, and sham trim groups and on day 14 in the trim-recovered group. In the trim group, the tongue onset latency was shorter in the left face-M1 than in the right face-M1 (P < .001). In the trim-recovered group, the number of tongue sites and jaw/tongue overlapping sites was greater in the left face-M1 than in the right face-M1 (P = 0.0032, 0.0016, respectively), and the center of gravity was deeper in the left than in the right face-M1 (P = 0.026). Therefore, incisor trimming and subsequent restoration of occlusal contacts induced face-M1 neuroplasticity, reflected in significant disparities between the left and right face-M1 in some ICMS-defined features of the tongue motor representations. Such neuroplasticity may reflect or contribute to subjects' ability to adapt their

  3. A hypothesis to explain division site selection in Escherichia coli by combining nucleoid occlusion and Min.

    PubMed

    Norris, Vic; Woldringh, Conrad; Mileykovskaya, Eugenia

    2004-03-12

    The positioning of the site of cell division in Escherichia coli results, it is generally believed, from the operation of nucleoid occlusion in combination with the Min system. Nucleoid occlusion prevents division over the nucleoids and directs it by default to the mid-cell region between segregating nucleoids or to polar regions while the Min system prevents division in polar regions. Unresolved questions include how these systems interact to control the earliest known event in division, the assembly at the membrane of the tubulin-like protein, FtsZ, and, more importantly, what exactly constitutes a division site. Evidence exists that (1) the coupled transcription, translation and insertion of proteins into membrane (transertion), can structure the cytoplasmic membrane into phospholipid domains, (2) the MinD protein can convert vesicles into tubes and (3) a variety of membranous structures can be observed at mid-cell. These data support a model in which transertion from the segregating daughter chromosomes leads to the formation of a distinct proteolipid domain between them at mid-cell; the composition of this domain allows phospholipid tubes to extend like fingers into the cytoplasm; these tubes then become the substrate for the dynamic assembly and disassembly of FtsZ which converts them into the invaginating fold responsible for division; the Min system inhibits division at unwanted sites and times by removing these tubes especially at the cell poles. PMID:15013745

  4. Plethysmography without venous occlusion for measuring forearm blood flow: comparison with venous occlusive method.

    PubMed

    Chuah, Seong S; Woolfson, Peter I; Pullan, Brian R; Lewis, Philip S

    2004-09-01

    Limb blood flow is widely used as an indicator of the human vascular properties. There are only few non-invasive methods for its measurement such as venous occlusion plethysmography. However, several authors have questioned its validity. The problems appear to be related to the process of venous occlusion. We developed two methods to measure forearm blood flow by plethysmography without venous occlusion in combination with Doppler velocimetry (without imaging). Method 1: the gradient of a tangent drawn on the latter part of the down stroke of the plethysmographic volume pulse is an approximation of venous blood flow in the absence of diastolic blood flow. At equilibrium, it equals the average arterial flow in a cardiac cycle. The Doppler velocity waveform recorded simultaneously allows improvement of this approximation when there is diastolic blood flow. Method 2: the volume pulse detected by a plethysmograph calibrated in absolute volume is used to calibrate the velocity waveform recorded simultaneously to produce an approximation of arterial volumetric flow waveform. Bland-Altman analysis shows both methods have good correlation and agreement with venous occlusion plethysmography at rest. Method 1: mean difference (blood flow measured by venous occlusion minus calculated flow) = 0.10 ml/pulse (+/-0.18), limits of agreement = -0.41 and 0.61 ml/pulse. Method 2: mean difference = -0.041 ml/pulse (+/-0.15), limits of agreement = -0.45 and 0.37 ml/pulse. During hyperaemia, venous occlusion plethysmography grossly underestimated relative to the new methods. The new methods are not dependent on venous occlusion and produce consistent results with or without hyperaemia. PMID:15383087

  5. Stent Recanalization of Chronic Portal Vein Occlusion in a Child

    SciTech Connect

    Cwikiel, Wojciech; Solvig, Jan; Schroder, Henrik

    2000-07-15

    An 8-year-old boy with a 21/2 year history of portal hypertension and repeated bleedings from esophageal varices, was referred for treatment. The 3.5-cm-long occlusion of the portal vein was passed and the channel created was stabilized with a balloon-expandable stent; a portosystemic stent-shunt was also created. The portosystemic shunt closed spontaneously within 1 month, while the recanalized segment of the portal vein remained open. The pressure gradient between the intrahepatic and extrahepatic portal vein branches dropped from 17 mmHg to 0 mmHg. The pressure in the portal vein dropped from 30 mmHg to 17 mmHg and the bleedings stopped. The next dilation of the stent was performed 12 months later due to an increased pressure gradient; the gastroesophageal varices disappeared completely. Further dilation of the stent was planned after 2, 4, and 6 years.

  6. Antiphospholipid Syndrome and Vascular Ischemic (Occlusive) Diseases: An Overview

    PubMed Central

    2007-01-01

    Antiphospholipid syndrome (APS) is primarily considered to be an autoimmune pathological condition that is also referred to as "Hughes syndrome". It is characterized by arterial and/or venous thrombosis and pregnancy pathologies in the presence of anticardiolipin antibodies and/or lupus anticoagulant. APS can occur either as a primary disease or secondary to a connective tissue disorder, most frequently systemic lupus erythematosus (SLE). Damage to the nervous system is one of the most prominent clinical constellations of sequelae in APS and includes (i) arterial/venous thrombotic events, (ii) psychiatric features and (iii) other non-thrombotic neurological syndromes. In this overview we compare the most important vascular ischemic (occlusive) disturbances (VIOD) with neuro-psychiatric symptomatics, together with complete, updated classifications and hypotheses for the etio-pathogenesis of APS with underlying clinical and laboratory criteria for optimal diagnosis and disease management. PMID:18159581

  7. Swine Model of Thrombotic Caval Occlusion Created by Autologous Thrombus Injection with Assistance of Intra-caval Net Knitting

    PubMed Central

    Shi, Wan-Yin; Wu, Shuang; Hu, Lan-Yue; Liu, Chang-Jian; Gu, Jian-Ping

    2015-01-01

    To evaluate the feasibility of a swine model of thrombotic inferior vena cava (IVC) occlusion (IVCO) created by autologous thrombus injection with assistance of intra-caval net knitting. Sixteen pigs were included and divided into two groups: Group A (n = 10), IVCO model created by knitting a caval net followed by autologous thrombus injection; Group B (n = 6), control model created by knitting a net and normal saline injection. Venography was performed to assess each model and the associated thrombotic occlusion. The vessels were examined histologically to analyse the pathological changes postoperatively. IVCO model was successfully created in 10 animals in Group A (100%). Immediate venography showed extensive clot burden in the IVC. Postoperative venography revealed partial caval occlusion at 7 days, and complete occlusion coupled with collateral vessels at 14 days. Histologically, Group A animals had significantly greater venous wall thickening, with CD163-positive and CD3-positive cell infiltration. Recanalization channels were observed at the margins of the thrombus. By contrast, no thrombotic occlusion of the IVC was observed in Group B. The thrombotic IVCO model can be reliably established in swine. The inflammatory reaction may contribute to the caval thrombus propagation following occlusion. PMID:26680253

  8. Development of Perceptual Completion Originates in Information Acquisition

    ERIC Educational Resources Information Center

    Johnson, Scott P.; Davidow, Juliet; Hall-Haro, Cynthia; Frank, Michael C.

    2008-01-01

    Adults have little difficulty perceiving objects as complete despite occlusion, but newborn infants perceive moving partly occluded objects solely in terms of visible surfaces. The developmental mechanisms leading to perceptual completion have never been adequately explained. Here, the authors examine the potential contributions of oculomotor…

  9. Photometric Ambient Occlusion for Intrinsic Image Decomposition.

    PubMed

    Hauagge, Daniel; Wehrwein, Scott; Bala, Kavita; Snavely, Noah

    2016-04-01

    We present a method for computing ambient occlusion (AO) for a stack of images of a Lambertian scene from a fixed viewpoint. Ambient occlusion, a concept common in computer graphics, characterizes the local visibility at a point: it approximates how much light can reach that point from different directions without getting blocked by other geometry. While AO has received surprisingly little attention in vision, we show that it can be approximated using simple, per-pixel statistics over image stacks, based on a simplified image formation model. We use our derived AO measure to compute reflectance and illumination for objects without relying on additional smoothness priors, and demonstrate state-of-the art performance on the MIT Intrinsic Images benchmark. We also demonstrate our method on several synthetic and real scenes, including 3D printed objects with known ground truth geometry. PMID:26959670

  10. Photoacoustic removal of occlusions from blood vessels

    DOEpatents

    Visuri, Steven R.; Da Silva, Luiz B.; Celliers, Peter M.; London, Richard A.; Maitland, IV, Duncan J.; Esch, Victor C.

    2002-01-01

    Partial or total occlusions of fluid passages within the human body are removed by positioning an array of optical fibers in the passage and directing treatment radiation pulses along the fibers, one at a time, to generate a shock wave and hydrodynamics flows that strike and emulsify the occlusions. A preferred application is the removal of blood clots (thrombin and embolic) from small cerebral vessels to reverse the effects of an ischemic stroke. The operating parameters and techniques are chosen to minimize the amount of heating of the fragile cerebral vessel walls occurring during this photo acoustic treatment. One such technique is the optical monitoring of the existence of hydrodynamics flow generating vapor bubbles when they are expected to occur and stopping the heat generating pulses propagated along an optical fiber that is not generating such bubbles.

  11. Characterization of a highly conserved baculovirus structural protein that is specific for occlusion-derived virions.

    PubMed

    Theilmann, D A; Chantler, J K; Stweart, S; Flipsen, H T; Vlak, J M; Crook, N E

    1996-04-01

    A highly conserved baculovirus late gene called odvp-6e was shown to be a structural protein that is specific for occlusion-derived virus (ODV) envelopes. The complete sequence of this gene is presented for both Orgyia pseudotsugata nuclear polyhedrosis virus (OpMNPV) and Cydia pomonella granulosis virus (CpGV). The predicted sizes of the OpMNPV and CpGV ODVP-6E are 40, 241, and 38,655 respectively. The OpMNPV odvp-6e gene was transcriptionally mapped and was shown to initiate from a consensus late gene motif, TTAAG, and is expressed from 18-120 hr postinfection. Polyclonal antiserum was generated against a bacterial fusion protein and used to analyze the cellular steady-state levels of ODVP-6E and to determine if this protein was a component of either budded virus (BV) or ODV. Western blots showed that ODVP-6E is a component of the ODV but not BV. This was confirmed by immunoelectron microscopy of ODV from Autographa californica NPV (AcMNPV) which localized ODVP-6E to the ODV envelope. The sequences of the odvp-6e gene from the baculoviruses Choristoneura fumiferana NPV (CfMNPV), AcMNPV, and Helicoverpa zea NPV (HzSNPV) were obtained from GenBank. Comparisons of the predicted amino acid sequences of OpMNPV, CpGV, AcMNPV, CfMNPV, and HzSNPV show that there are two possible membrane-spanning domains and a cysteine-rich domain that are conserved in all of the proteins. PMID:8615018

  12. [TMJ morphological changes in abnormal occlusion].

    PubMed

    Volkov, S I; Bazhenov, D V; Semkin, V A; Bogdanov, A O

    2013-01-01

    TMJ dysfunction is one of the most common diseases among all disorders of the maxillofacial region. Any abnormality in synchrony or amplitude of motion of the TMJ results in the malposition of the articular disc. Researchers and clinicians were always interested in topographic anatomy of the TMJ. There is currently no consensus on matters relating to changes in anatomical features of the TMJ by occlusal disturbances. PMID:23715443

  13. Study of laser vas deferens occlusion.

    PubMed

    Xiao, X; Zhao, Q; Zhou, S; Jin, G; Wang, S; Luo, G

    2001-10-01

    The objective of this study was to determine threshold levels for high-power laser output Nd:YAG laser photocoagulation and to determine the possible reversibility of laser vas occlusion. The study included vas deferens of 220 rabbits and 20 samples of men in vitro, applying the Nd:YAG laser instrument, doing vasopuncture by a catheter needle, guiding the fiber into the vas, and performing the irradiation occlusion experiment to determine effective threshold value of photocoagulation. The effect and safety of occlusion were followed-up over a year, and reopening a experiment was done in 60 occluded nodes of rabbits. The postoperative sperm disappearance rate was 100%, and reopening rate was 72.7% without obvious complications. High-power lasers may be used as photocoagulation, and its merits are reliable, effective, and rapid recovery. The vas threshold lesion value of rabbits and men in vitro are 50 W/0.5 s, 45 W/1 s, respectively, and irradiation depth reached the middle-ring muscularis. PMID:11747875

  14. Crossing Total Occlusions: Navigating Towards Recanalization.

    PubMed

    Sakes, Aimée; Regar, Evelyn; Dankelman, Jenny; Breedveld, Paul

    2016-06-01

    Chronic total occlusions (CTOs) represent the "last frontier" of percutaneous interventions. The main technical challenges lies in crossing the guidewire into the distal true lumen, which is primarily due to three problems: device buckling during initial puncture, inadequate visualization, and the inability to actively navigate through the CTO. To improve the success rate and to identify future research pathways, this study systematically reviews the state-of-the-art of all existing and invented devices for crossing occlusions. The literature search was executed in the databases of Scopus and Espacenet using medical and instrument-related keyword combinations. The search yielded over 840 patents and 69 articles. After scanning for relevancy, 45 patents and 16 articles were included. The identified crossing devices were subdivided based on the determinant for the crossing path through the occlusion, which is either the device (straight and angled crossing), the environment (least resistance, tissue selective, centerline, and subintimal crossing) or the user (directly steered and sensor enhanced crossing). It was found that each crossing path is characterized by specific advantages and disadvantages. For a future crossing device, a combination of crossing paths is suggested were the interventionist is able to exert high forces on the CTO (as seen in the device approach) and actively steer through the CTO (user: directly steered crossing) aided by intravascular imaging (user: sensor enhanced crossing) or an intrinsically safe device following the centerline or path of least resistance (environment: centerline crossing or least resistance crossing) to reach the distal true lumen. PMID:26831298

  15. Clinical Results of Percutaneous Transluminal Angioplasty and Stenting for Intracranial Vertebrobasilar Atherosclerotic Stenoses and Occlusions

    PubMed Central

    Tsuura, M.; Terada, T.; Masuo, O.; Tsumoto, T.; Yamaga, H.; Itakura, T.; Matsumoto, H.; Hyoutani, G.; Hayashi, S.

    2004-01-01

    Summary Eighteen patients with intracranial vertebrobasilar stenosis and occlusion were treated by PTA or stenting. In 11 of 18 cases, only PTA was performed and in seven of 18 cases, we used stents. The mean stenosis before and after PTA/stenting was 82.8% and 22.3%, respectively. In 11 cases of PTA only, the stenotic rate decreased from 81.8% to 29.6%, while 85.0% of the stenotic rate remarkably reduced to 6.0% in seven cases of stenting. The 30 days morbidity and 30 days mortality rate were 5.5% and 5.5%, respectively. There was only one haemorrhagic complication (cerebellar haemorrhage) in cases of stenting, and no ischemic events during or after the procedures. Restenosis (more than 50% stenosis) occurred in four of 18 cases(22.2%) during mean follow-up period of 12 months. Two patients with VA occlusion before treatment, developed restenosis and reocclusion. Complete total occlusion seems to be a high-risk lesion and strict follow-up is required. In this study, PTA/stenting for intracranial vertebrobasilar artery stenosis or occlusion is an effective treatment, but strict indications may be required because procedure-related 30 days morbidity rate was 5.5% in addition to unclear natural history. PMID:20587244

  16. Bioabsorbable radiopaque water-responsive shape memory embolization plug for temporary vascular occlusion.

    PubMed

    Wong, Yee Shan; Salvekar, Abhijit Vijay; Zhuang, Kun Da; Liu, Hui; Birch, William R; Tay, Kiang Hiong; Huang, Wei Min; Venkatraman, Subbu S

    2016-09-01

    We describe the preparation, characterization and evaluation of a biodegradable radiopaque water-triggered shape memory embolization plug for temporary vascular occlusion. The shape memory occluding device consists of a composite of a radio-opaque filler and a poly (dl-lactide-co-glycolide) (PLGA) blend, which was coated with a crosslinked poly (ethylene glycol) diacrylate (PEGDA) hydrogel. The mechanical properties, the degradation timeframe, the effect of programming conditions on the shape memory behaviour and the extent of radio-opacity for imaging were evaluated. Based on the tests, the mechanism responsible for the water-induced shape memory effect in such an embolization plug was elucidated. Suitable materials were optimized to fabricate an embolic plug prototype and its in vitro performance was evaluated as an occlusion rate (using a custom-built set up) and its biocompatibility. Finally, a feasibility study was conducted in vivo in a rabbit model to investigate the ease of device deployment, device migration and extent of vessel occlusion. The in vivo results demonstrated that the prototypes were visible under fluoroscopy and complete vascular occlusion occurred within 2 min of deployment of the prototypes in vivo. In conclusion, the developed embolization plug enables controlled and temporary vascular embolization, and is ready for safety studies. PMID:27322962

  17. Vascular Reactivity: Evaluation of an acute suprasystolic occlusion with impedance plethysmography

    NASA Astrophysics Data System (ADS)

    Herrera, M. C.; Bonaudo, M.; Conde, A.; Palavecino, L.

    2007-11-01

    In the clinical set, the evaluation of endothelium- dependent vasodilator response of large vessels is carried out using ultrasound equipment for vascular flow determinations and during administration of vasoactive drugs. This work proposes to use a substantially cheaper technique and a sustained cuff arterial occlusion in order to cause vasodilation. Impedance plethysmography is used to detect the arterial pulse wave over radial artery while the forearm is occluded by above the recording site. From these plethysmographic waves, three indexes and their changes -between control and maximal response post-occlusion- were calculated. 33 complete records obtained from healthy low-risk volunteers were analyzed. Between control and post-occlusion maximal response, "average percentual change of pulse wave amplitude" were (35±13)%, "stiffness index" did not show significant differences (6,38±0,98 vs 6,38±0,94 and "reflection index" was significant lower (58±15 vs 35±16)%. These results indicate that: 1- cuff occlusion maneuver was effective to cause endothelium-dependent vasodilation, 2-changes of pulse wave amplitude and reflection index could be used as markers of athero-arteriosclerotic damage in the vascular bed, even in sub-clinical conditions.

  18. [Successful Treatment of Repeated Bilateral Middle Cerebral Artery Occlusion by Performing Mechanical Thrombectomy in a Patient with Trousseau Syndrome].

    PubMed

    Inoue, Satoshi; Fujita, Atsushi; Mizowaki, Takashi; Uchihashi, Yoshito; Kuroda, Ryuichi; Urui, Seishirou; Kurihara, Eiji; Kohmura, Eiji

    2016-06-01

    We report a patient with Trousseau syndrome who presented with repeated acute middle cerebral artery (MCA) occlusion, which was successfully treated by performing mechanical thrombectomy. A 66-year-old man with a lung lesion and abdominal lymph node swelling experienced a sudden onset of left hemiparesis. Magnetic resonance angiography (MRA) revealed a right MCA occlusion. Perfusion-weighted imaging revealed reduced cerebral blood flow in the right MCA territory. Complete recanalization of the occluded vessel was achieved by performing mechanical thrombectomy, and his symptoms remarkably disappeared. Twenty days after the procedure, he experienced right hemiparesis and total aphasia. MRA revealed a left MCA occlusion, which was located on the contralateral side of the first occlusion. The second mechanical thrombectomy was successfully performed, and complete recanalization was successfully achieved. Right hemiparesis improved after the procedure. Histological examination of the retrieved clots revealed coagulated fibrin and platelets. Cytodiagnosis of pleural effusion revealed adenocarcinoma, and he was diagnosed with lung adenocarcinoma and cancerous pleurisy. Trousseau syndrome was the presumed primary cause of the patient's tendency for thrombogenesis. To the best of our knowledge, there were no reports regarding the repeated use of mechanical thrombectomy for patients with bilateral MCA occlusion caused by Trousseau syndrome. Neuroendovascular therapy can offer good neurological outcomes even in patients with malignant lesions. PMID:27270149

  19. Occlusion and weight change in a patient after esophagectomy: success derived from restoration of occlusal support.

    PubMed

    Yamanaka, Reiko; Soga, Yoshihiko; Minakuchi, Mami; Nawachi, Kumiko; Maruyama, Takayuki; Kuboki, Takuo; Morita, Manabu

    2013-01-01

    Occlusal support may be an important factor affecting nutritional support after major surgery. This report presents a patient who gained body weight after receiving a new prosthesis. The patient was an 82-year-old man with thoracic esophageal carcinoma. He did not have occlusal support because of multiple caries lesions. His body weight slowly increased after surgery, but almost stopped in the period of 54 to 68 days after surgery. After treatment with dentures (day 72 postsurgery), body weight gain was observed again, although his medical treatment had not changed. An appropriate prosthesis could contribute to perioperative nutrition support and may lead to earlier recovery after surgery. PMID:24179973

  20. Complete diphallia.

    PubMed

    Acimi, Smail

    2008-01-01

    A case of complete diphallia in a 4-month-old boy is reported. This is the second case to be published from this institution. The embryogenesis and associated anomalies of diphallia are discussed, together with a proposal for a classification based on anatomical, functional and therapeutic aspects of the malformation. PMID:19230173

  1. Intraoperative portal vein insulin assay combined with occlusion of the pancreas for complex pancreatogenous hypoglycemia

    PubMed Central

    Yang, Zhiying; Tan, Haidong; Sun, Yongliang; Si, Shuang; Xu, Li; Liu, Xiaolei; Liu, Liguo; Zhou, Wenying; Huang, Jia

    2016-01-01

    Abstract Intraoperative localization and confirmation of complete resection of the hypersecreting tissue are the 2 main challenges in the management of pancreatogenous hypoglycemia. Here, we report our experience with intraoperative portal vein insulin assay combined with occlusion of the pancreas in the management of pancreatogenous hypoglycemia. Clinical courses of 2 patients with biochemical evidence of a pancreatogenous hypoglycemia were studied. The preoperative diagnosis was multiple endocrine neoplasia 1 (MEN-1) and nesidioblastosis, respectively. Rapid intraoperative portal vein insulin assay combined with occlusion of the pancreas was used to localize and confirm complete excision of the hypersecreting tissue. Hypoglycemia was successfully treated in both the patients. In the MEN-1 patient, 2 small tumors in the head of pancreas were not resected, as they were deemed noninsulin secreting by intraoperative portal vein insulin assay, thus avoiding a total pancreatectomy. In the patient with nesidioblastosis, using intraoperative portal vein insulin assay combined with occlusion of the pancreas, an appropriate amount of pancreatic tissue was resected thereby avoiding recurrence and diabetes. This technique may be of particular value in patients with complex conditions such as MEN-1 and nesidioblastosis, to localize and achieve complete resection of hypersecreting pancreatic tissue. PMID:27367988

  2. Dental occlusion modifies gaze and posture stabilization in human subjects.

    PubMed

    Gangloff, P; Louis, J P; Perrin, P P

    2000-11-01

    Repercussion of dental occlusion was tested upon postural and gaze stabilization, the latter with a visuo-motor task evaluated by shooting performances. Eighteen permit holders shooters and 18 controls were enrolled in this study. Postural control was evaluated in both groups according to four mandibular positions imposed by interocclusal splints: (i) intercuspal occlusion (IO), (ii) centric relation (CR), (iii) physiological side lateral occlusion and (iv) controlateral occlusion, in order to appreciate the impact of the splints upon orthostatism. Postural control and gaze stabilization quality decreased, from the best to the worst, with splints in CR, IO and lateral occlusion. In shooters, the improvement in postural control was parallel to superior shooting performance. A repercussion of dental occlusion upon proprioception and visual stabilization is suggested by these data. PMID:11036196

  3. Dental Occlusion Influences the Standing Balance on an Unstable Platform.

    PubMed

    Julià-Sánchez, Sonia; Álvarez-Herms, Jesús; Gatterer, Hannes; Burtscher, Martin; Pagès, Teresa; Viscor, Ginés

    2015-10-01

    Contradictory results are still reported on the influence of dental occlusion on the balance control. We attempted to determine whether there are differences in balance between opposed dental occlusion (Intercuspal position (ICP)/"Cotton rolls" mandibular position [CR]) for two extreme levels of stability (stable/ unstable). Twenty-five subjects were monitored under both dental occlusion and level of stability conditions using an unstable platform Balance System SD. The resulting stability index suggests that body balance is significantly better when dental occlusion is set in CR (p < .001) in unstable but not in stable conditions. Occlusal traits significantly influencing postural control were Angle Class (p < .001), crowding (p = .006), midline deviation (p < .001), crossbite (p < .001), anterior open bite (p = .05), and overjet (p = .01). It could be concluded that the sensory information linked to the dental occlusion for the balance control comes strongly into effect in unstable conditions. PMID:25674772

  4. Arterial gas occlusions in operating heat pipes

    NASA Technical Reports Server (NTRS)

    Saaski, E. W.

    1975-01-01

    The effect of noncondensable gases on high performance arterial heat pipes has been investigated both analytically and experimentally. Models have been generated which characterize the dissolution of gases in condensate and the diffusional loss of dissolved gases from condensate in arterial flow. These processes, and others, have been used to postulate stability criteria for arterial heat pipes. Experimental observations of gas occlusions were made using a stainless steel heat pipe equipped with viewing ports, and the working fluids methanol and ammonia with the gas additives helium, argon, and xenon. Observations were related to gas transport models.

  5. Collagen plug occlusion of Molteno tube shunts.

    PubMed

    Stewart, W; Feldman, R M; Gross, R L

    1993-01-01

    We report five patients in whom collagen lacrimal plugs were used to temporarily occlude the lumen of Molteno shunts to prevent early postoperative hypotony. Only one eye, with a double plate, developed hypotony and a flat anterior chamber that required reformation. However, in three patients, the collagen plugs did not dissolve and had to be removed surgically to lower the intraocular pressure. Although the semipermeability of collagen is desirable, its unpredictable degradation renders it unsuitable for temporary occlusion of tube shunts. Other biodegradable materials may be more appropriate for this purpose. PMID:8446334

  6. Trigeminal trophic syndrome treated with thermoplastic occlusion.

    PubMed

    Kurien, Anil M; Damian, Diona L; Moloney, Fergal J

    2011-02-01

    A 72-year-old man with a history of thrombotic CVA causing lateral medullary infarction presented with non-healing ulcers of the right side of the face of 5 months' duration. After extensive investigations, a diagnosis of trigeminal trophic syndrome was made. The ulcers progressed relentlessly despite amitriptyline and gabapentin, and he was treated with a combination of carbamazepine and thermoplastic mask occlusion of the right side of his face. Over the next 10 weeks the shallower facial ulcers began to diminish in depth and diameter, and the deeper ulcers stopped progressing. Although the patient showed early signs of healing, he died because of complications from the CVA. PMID:21332680

  7. Evaluation of a new liquid occlusive dressing for excisional wounds.

    PubMed

    Singer, Adam J; Nable, Maria; Cameau, Paul; Singer, Daniel D; McClain, Steve A

    2003-01-01

    We evaluated a novel octylcyanoacrylate-based liquid occlusive dressing for partial-thickness wounds. One hundred and fifteen standardized wounds were created with an electric dermatome set at a depth of 600 micro on the flanks of three pigs and randomly treated with liquid occlusive dressing, a hydrocolloid dressing, or gauze. In one pig, wounds were swabbed with Staphylococcus aureus. Biopsies were taken after 4, 5, 6, and 21 days. Hemostasis was obtained in all wounds treated with the liquid occlusive. The percent reepithelialization of wounds treated with the liquid occlusive and hydrocolloid dressings were significantly greater at days 4 and 5 than control wounds (78% and 82% vs. 40%, p < 0.001 and 99% and 100% vs. 72%, p < 0.001, respectively). None of the liquid occlusive-treated wounds challenged with bacteria became infected. Foreign body reactions were least common in wounds treated with the liquid occlusive (p < 0.001). Scar depth was less for liquid occlusive- and hydrocolloid-treated wounds than controls (285 micro and 303 micro vs. 490 micro, p < 0.001). We conclude that excisional wounds treated with the liquid occlusive dressing reepithelialize as quickly as hydrocolloid-treated wounds. The liquid occlusive dressing is an effective microbial barrier and hemostatic agent resulting in fewer foreign body reactions than hydrocolloid-treated wounds or controls. PMID:12753599

  8. Depth discrimination from occlusions in 3D clutter.

    PubMed

    Langer, Michael S; Zheng, Haomin; Rezvankhah, Shayan

    2016-09-01

    Objects such as trees, shrubs, and tall grass consist of thousands of small surfaces that are distributed over a three-dimensional (3D) volume. To perceive the depth of surfaces within 3D clutter, a visual system can use binocular stereo and motion parallax. However, such parallax cues are less reliable in 3D clutter because surfaces tend to be partly occluded. Occlusions provide depth information, but it is unknown whether visual systems use occlusion cues to aid depth perception in 3D clutter, as previous studies have addressed occlusions for simple scene geometries only. Here, we present a set of depth discrimination experiments that examine depth from occlusion cues in 3D clutter, and how these cues interact with stereo and motion parallax. We identify two probabilistic occlusion cues. The first is based on the fraction of an object that is visible. The second is based on the depth range of the occluders. We show that human observers use both of these occlusion cues. We also define ideal observers that are based on these occlusion cues. Human observer performance is close to ideal using the visibility cue but far from ideal using the range cue. A key reason for the latter is that the range cue depends on depth estimation of the clutter itself which is unreliable. Our results provide new fundamental constraints on the depth information that is available from occlusions in 3D clutter, and how the occlusion cues are combined with binocular stereo and motion parallax cues. PMID:27618514

  9. [Research Advances in Baculovirus Occlusion-derived Virions].

    PubMed

    Zhu, Shimao; Li, Hui

    2016-01-01

    Baculoviruses are a family of arthropod-specific viruses that produce two morphologically distinct types of virions (budded and occlusion-derived) in their lifecycle. Baculoviruses establish infection in the midgut of their host via the oral route: occlusion-derived virions have pivotal roles in these processes. This review summarizes the basic characteristics of baculoviruses, and discusses the composition and classification of baculovirus occlusion-derived virions. The latter focuses mainly on the evolution and role of multiple occlusion-derived virions in the lifecycle of baculoviruses. These achievements should aid understanding the evolution and infection mechanisms of baculoviruses. PMID:27295890

  10. Meningioma and occlusive vasculopathy: coexisting complications of past extracranial radiation

    SciTech Connect

    Montanera, W.; Chui, M.; Hudson, A.

    1985-07-01

    Two cases are reported in which a meningioma and occlusion of the internal carotid artery with development of transdural collateral circulation coexisted following extracranial radiation in childhood.

  11. Acute middle cerebral artery occlusion: reappraisal of the role of endovascular revascularization.

    PubMed

    Cohen, José E

    2013-02-01

    Intravenous tissue plasminogen activator was the first successful stroke therapy in acute ischaemic stroke, after innumerable failed attempts at neuroprotection and neurorestoration. However, intravenous tissue type plasminogen activator has been shown to be effective in recanalizing middle cerebral artery occlusions in only about one-third of cases. The natural history of untreated acute middle cerebral artery occlusion is poor, leading to long-term disability in >70% and mortality in 20%. Recanalization alone is not the name of the game. Only timely, very rapid recanalization, achieved within minutes or at most a few hours after stroke has occurred, before irreversible brain damage develops, is effective. Is intravenous tissue type plasminogen activator the best available option we have for these patients? With recently introduced stent-based thrombectomy devices, neurointerventionalists have achieved complete recanalization rates of more than 90% in middle cerebral artery and 'T' occlusions, with a mean procedural recanalization time of less than one-hour and negligible complication rates. More than 80% of patients less than 80 years of age who were treated within eight-hours after stroke onset in our centre achieved a modified Rankin score of 0-2 at three-month follow-up. The site of arterial occlusion is a factor driving the choice between a standard intravenous tissue type plasminogen activator protocol and an alternative intervention such as intravenous and/or mechanical thrombolysis to achieve early recanalization. The role of intravenous tissue type plasminogen activator must be redefined in major occlusions, and the indications for endovascular therapy must also be reappraised. PMID:23336262

  12. [Accidental occlusion of the common femoral artery after Angio-Seal-application].

    PubMed

    Silber, S; Schön, N; Seidel, N; Heiss-Bogner, J

    1998-01-01

    Removal of the arterial sheath immediately after PTCA is desirable for patients, reduces the medical staff's workload, and may decrease hospital costs due to a shortened length of stay. Although the safety and efficacy of the hemostatic systems used especially for the above purpose have been sufficiently documented, inadvertent intraluminal vascular occlusion is theoretically possible. While partial or complete arterial occlusion in conjunction with the VasoSeal collagen prototype device has been previously reported, similar complications occurring with the Angio-Seal device were not published. In this report, we describe a 54-year old female patient (height: 150 cm, weight: 42.5 kg) who was transferred for PTCA following an acute anterior wall myocardial infarction. Immediately after PTCA, the Angio-Seal device was deployed utilizing standard technique. No difficulties were encountered during device deployment, however, immediately following device placement active arterial bleeding occurred. Due to the inadequacy of hemostasis, heparin was reversed with protamine to avoid further hemorrhagic complications. Following this, the desired hemostasis quickly occurred, but the patient soon complained about symptoms suggestive of an acute occlusion of the right femoral artery. Unsatisfactory attempts at lysis resulted in the patient being transferred to vascular surgery. The complete Angio-Seal system (anchor including collagen) was located intravascularly, and removed during surgery. This case report demonstrates that even an experienced examiner can inadvertently deploy the Angio-Seal completely intraarterially. In addition to the known contraindication, "peripheral arterial occlusive disease", we recommend that the Angio-Seal device not be utilized in patients of small physical size. PMID:9531701

  13. Complete prewetting

    NASA Astrophysics Data System (ADS)

    Yatsyshin, P.; Parry, A. O.; Kalliadasis, S.

    2016-07-01

    We study continuous interfacial transitions, analagous to two-dimensional complete wetting, associated with the first-order prewetting line, which can occur on steps, patterned walls, grooves and wedges, and which are sensitive to both the range of the intermolecular forces and interfacial fluctuation effects. These transitions compete with wetting, filling and condensation producing very rich phase diagrams even for relatively simple prototypical geometries. Using microscopic classical density functional theory to model systems with realistic Lennard-Jones fluid–fluid and fluid–substrate intermolecular potentials, we compute mean-field fluid density profiles, adsorption isotherms and phase diagrams for a variety of confining geometries.

  14. Percutaneous Thrombin Injection of a Femoral Artery Pseudoaneurysm with Simultaneous Venous Balloon Occlusion of a Communicating Arteriovenous Fistula

    SciTech Connect

    Mittleider, Derek Cicuto, Kenneth; Dykes, Thomas

    2008-07-15

    An 82-year-old woman developed acute occlusion of her right coronary artery. She underwent percutaneous coronary stent placement and aortic balloon pump installation. In the postprocedural period, she developed a common femoral artery pseudoaneurysm (PSA) that communicated with the common femoral vein via an arteriovenous fistula (AVF). After unsuccessful ultrasound-guided compression, ultrasound-guided thrombin injection of the PSA was performed, with simultaneous balloon occlusion of the common femoral vein at the level of the AVF. There was complete thrombosis of the PSA and AVF.

  15. Penetrating Atherosclerotic Ulcer of the Abdominal Aorta Involving the Celiac Trunk Origin and Superior Mesenteric Artery Occlusion: Endovascular Treatment

    SciTech Connect

    Ferro, Carlo; Rossi, Umberto G. Petrocelli, Francesco; Seitun, Sara; Robaldo, Alessandro; Mazzei, Raffaele

    2011-02-15

    We describe a case of endovascular treatment in a 64-year-old woman affected by a penetrating atherosclerotic ulcer (PAU) of the abdominal aorta with a 26-mm pseudoaneurysm involving the celiac trunk (CT) origin and with superior mesenteric artery (SMA) occlusion in the first 30 mm. The patient underwent stenting to treat the SMA occlusion and subsequent deployment of a custom-designed fenestrated endovascular stent-graft to treat the PAU involving the CT origin. Follow-up at 6 months after device placement demonstrated no complications, and there was complete thrombosis of the PAU and patency of the two branch vessels.

  16. Intraluminal occlusion of the seminal duct by laser and Histoacryl: Two non-invasive alternatives for vasectomy

    NASA Astrophysics Data System (ADS)

    Freitag, B.; Sroka, R.; Koelle, S.; Becker, A. J.; Khoder, W.; Pongratz, T.; Stief, C. G.; Trottmann, M.

    2014-03-01

    Introduction and objective: Vasectomy is a well-established method in family control. Even though it is a safe and low risk operation, this surgery is invasive and difficult to reverse. Therefore the aim of this study was to investigate new non-invasive methods for occlusion of the seminal duct. Material and Methods: Seminal duct tissue was obtained from patients (n=30) suffering from prostate cancer and therefore undergoing prostatectomy. In a first set of experiments, the seminal duct was occluded by intraluminal application of Histoacryl® (Braun Aesculap AG, Tuttlingen, Germany). In a 2nd set of experiments, endoluminal laser induced occlusion was performed. Four different laser wavelengths (1940nm, 1470nm, 1064nm, 940nm) and different sets of laser parameters (e.g. power, exposure duration, fibre diameter, energy applied) were compared. Effectiveness of occlusion of the seminal duct was proven by post-treatment irrigation flow measurement, as well as by morphological analyses. To evaluate a potential damage of the surrounding tissue, external temperature was measured using a thermometer during laser application. Results: Intraluminal application of Histoacryl® induced an immediate and complete occlusion of the seminal duct. The underlying connective tissue maintained its functional integrity after this treatment. By laser light application to a Histoacryl® block, a hole could be created into the block thus indicating the possibility of recanalization. Treatment with laser energy resulted in shrinkage of the ductal lumen. The laser application generally caused necrosis in the epithelium and induced formation of vacuoles in the underlying connective tissue. As described for endoluminal varicose treatment, this distinct local reaction might result in an intense inflammation leading to a functional occlusion of the vas deferens. Conclusions: Both laser-induced occlusion and application of Histoacryl® are fast and simple techniques which may be able to achieve a

  17. Computerized occlusal analysis: correlation with occlusal indexes to assess the outcome of orthodontic treatment or the severity of malocculusion

    PubMed Central

    Lee, Jin-Woo

    2016-01-01

    Objective The aims of our study were to verify the validity of the T-Scan III system (Tekscan) as an objective occlusal evaluation tool, and to assess the differences between two occlusal indexes-the peer assessment rating (PAR) index and the American Board of Orthodontics objective grading system (OGS)-by comparing the scores derived from the T-Scan III system with the two occlusal indexes and analyzing the correlations between them. Methods The final study sample included 48 adult volunteers (39 men and 9 women, mean age 24.14 ± 3.16 years), after excluding 29 volunteers whose occlusion could not be evaluated by the T-Scan III system due to severe skeletal or occlusal problems. PAR index and OGS scores were assessed using dental study models, and measurements of centric occlusion, protrusive movement, and lateral excursion movement were obtained via the T-Scan III system. The results were analyzed to determine correlations. Results Occlusal analysis by the T-Scan III system was clinically reliable (p < 0.05), and the PAR index and OGS scores were significantly correlated with several measurements obtained with the T-Scan III system (p < 0.05). Conclusions The T-Scan III system is a quantitative and reliable method for occlusal evaluation, and represents a potential substitute for occlusal indexes. Compared to the PAR index, the OGS scores of more variables were significantly correlated with the T-Scan measurements. PMID:26877980

  18. Numerical analysis of human dental occlusal contact

    NASA Astrophysics Data System (ADS)

    Bastos, F. S.; Las Casas, E. B.; Godoy, G. C. D.; Meireles, A. B.

    2010-06-01

    The purpose of this study was to obtain real contact areas, forces, and pressures acting on human dental enamel as a function of the nominal pressure during dental occlusal contact. The described development consisted of three steps: characterization of the surface roughness by 3D contact profilometry test, finite element analysis of micro responses for each pair of main asperities in contact, and homogenization of macro responses using an assumed probability density function. The inelastic deformation of enamel was considered, adjusting the stress-strain relationship of sound enamel to that obtained from instrumented indentation tests conducted with spherical tip. A mechanical part of the static friction coefficient was estimated as the ratio between tangential and normal components of the overall resistive force, resulting in μd = 0.057. Less than 1% of contact pairs reached the yield stress of enamel, indicating that the occlusal contact is essentially elastic. The micro-models indicated an average hardness of 6.25GPa, and the homogenized result for macroscopic interface was around 9GPa. Further refinements of the methodology and verification using experimental data can provide a better understanding of processes related to contact, friction and wear of human tooth enamel.

  19. Smile line and occlusion: An epidemiological study

    PubMed Central

    Harati, Mahsa; Mostofi, Shahbaz Naser; Jalalian, Ezzatollah; Rezvani, Gholamreza

    2013-01-01

    Background: The purpose of the present study was to discuss some new concepts of the desirable characteristics of smile tooth display. Due to the increasing application of cosmetic dental treatments, there is an increasing need for better understanding of the esthetic principles. Materials and Methods: In the present descriptive study, with 212 participants, included were patients with no history of orthodontic treatment, loss or prosthetic replacement of anterior teeth, extracted teeth, lips with asymmetry or a history of trauma. Chi-square test was used to determine possible significances in the relation of smile line to Angle occlusion class, overbite and overjet and arch form. A P level of <0.05 was set as to be significant. Results: Chi-square test indicated that there was a significant difference between the smile design and overbite, overjet and gender but no statistically significant association was found between the smile design and crossbite, molar Angle classification and arch form. Conclusion: Within the limitations of such studies, it might be concluded that there is a significant and important relation between some occlusal parameters and smile design, which must be considered. PMID:24379858

  20. Recurrent syncope after left atrial appendage occlusion.

    PubMed

    Cruz-Gonzalez, Ignacio; Perez-Rivera, Jose-Angel; Bethencourt, Armando

    2015-02-01

    We present the case of a 72-year-old woman with permanent atrial fibrillation and contraindication to long-term oral anticoagulant therapy who underwent left atrial appendage (LAA) occlusion. A 24-mm Amplatzer Cardiac Plug (St Jude Medical) device was deployed. The inferior part of the external disc of the device appeared to be over the posterior leaflet of the mitral valve but no significant mitral stenosis or mitral regurgitation was detected before deployment. After the procedure the patient suffered several syncopes when she tried to stand up. A transesophageal echocardiography (TEE) was performed and no significant differences on the device position were detected, it was not possible to perform the TEE in a stand-up position due to the patient symptoms (hypotension, tachycardia, dizziness, and loss of consciousness). After discussion with the surgical team, surgical removal of the device and surgical exclusion of LAA was performed. The symptoms disappeared and the patient was discharged. In the best of our knowledge, this is the first time that recurrent syncope has been described as a complication of LAA occlusion. PMID:25044597

  1. Anthropology, tooth wear, and occlusion ab origine.

    PubMed

    Young, W G

    1998-11-01

    The purpose of this essay is to emphasize that anthropology, the study of man in his environments, is a potent tool for scientific discovery and inspiration in dental science. It attempts to capture flashes of creative anthropological insight which have illuminated studies of tooth wear and occlusion in the past. While it documents contributions, understandings, and misunderstandings from Australian and New Zealand dentists, it is not a hagiography. The real saint of this essay is the Australian aborigine. For when men and women are understood in their environments, much is learned from them which challenges preconceptions of our dental science culture. The essay concludes that new, contemporary Australian culture needs to be studied by anthropological approaches if we are to understand how dental erosion is exacerbating tooth wear and damaging the occlusions of contemporary Australians. Much remains to be discovered about contemporary lifestyles, habits, and diets that lead to dental erosion, the principal cause of contemporary tooth wear in this part of the world. PMID:9823723

  2. Complete denture fabrication with CAD/CAM record bases.

    PubMed

    McLaughlin, J Bryan; Ramos, Van

    2015-10-01

    One of the primary goals of new materials and processes for complete denture fabrication has been to reduce polymerization shrinkage. The introduction of computer-aided design and computer-aided manufacturing (CAD/CAM) technology into complete denture fabrication has eliminated polymerization shrinkage in the definitive denture. The use of CAD/CAM record bases for complete denture fabrication can provide a better-fitting denture with fewer postprocessing occlusal errors. PMID:26139040

  3. Approach to evidence of middle ear occlusion effect by laser vibrometry

    NASA Astrophysics Data System (ADS)

    Vogel, Uwe; Zahnert, Thomas; Hofmann, Gert; Huettenbrink, Karl-Bernd

    1996-12-01

    In the beginning of the last century German anatomist E. H. Weber first reported an audiological phenomenon. Up to now Weber's test is widely used by the otologists for the differentiation of sound conduction and inner ear disorders. The sound of an excited tuning-fork on the top of the head will be lateralized into the ear with an occluded ear canal (occlusion effect). But so far there has been no objective criterion for this effect on humans or temporal bone preparations. We have performed various approaches for the measurement of the occlusion effect. The slow cortical acoustical evoked potentials (SAEP) on both sides after bone conduction stimulation of the vertex at several test persons. We succeeded in proving a decrease of latency during occlusion of ear canal. This has been an electrophysiological approach. However, the theory gives reasons for this effect by changed acoustical impedance conditions of the ear canal due to its occlusion. The related increased sound pressure level (SPL) inside the ear canal results in unilateral amplification effect and its transfer via the middle ear into the inner ear, and therefore performs a lateralization. Thus one should be able to measure this amplification in temporal bone preparations too. Laser vibrometry allows a non-contact access to the tympanic membrane and the middle ear apparatus. The tympanic membrane transforms the ear canal's amplified sound pressure into increased mechanical vibration of the ossicular chain and eventually the stapes footplate affecting the inner ear liquid. That is why we positioned the beam of a laser vibrometer at the inner ear side of the footplate. The preparation was broadband-excited by a bone conduction vibrator. During occlusion of the ear canal an increased sound pressure level inside the ear canal was registered by a probe microphone. By assuming a transfer of this SPL increase onto the footplate we measured its displacement by laser vibrometry. Generally lower gains could have

  4. Dental occlusion: modern concepts and their application in implant prosthodontics.

    PubMed

    Carlsson, Gunnar E

    2009-01-01

    The aim of this article was to review the literature on various aspects of occlusion related to implant prosthodontics, using PubMed and the Cochrane library. Even if the number of studies on implants and prosthodontics is very large, no randomized controlled trials or Cochrane reviews were found on the possible influence of occlusal design or characteristics of occlusion on treatment outcome. Therefore, studies and articles of a lower evidence level were accepted as the main part of the review. The widely spread opinion that implants are superior to natural teeth was refuted by two recent consensus conferences, which concluded that the long-term outcome of implant restorations is not better than that of natural teeth. No controlled studies on the optimal features of a harmonious natural and/or restored occlusion, including implant prostheses, were found. Nor was there any evidence that more sophisticated methods in jaw registration, e.g., using face-bows and adjustable articulators, compared with simpler methods, will yield better clinical prosthodontic results. This article discusses, among other things, concepts of occlusion of implant-supported restorations, occlusal material, cantilevers, and occlusal risk factors. Within the limitations of the review, it was concluded that many factors can influence implant failure and peri-implant bone loss but that little is known of the relative importance of such factors. Most probably, however, occlusal factors and details of occlusion are in general of minor importance for the outcome of implant restorations. Occlusion can be managed successfully by using simple methods for jaw registration and different occlusal concepts. PMID:19184293

  5. Coronary artery occlusion after arterial switch operation in an asymptomatic 15-year-old boy.

    PubMed

    Saini, Ashish P; Cyran, Stephen E; Ettinger, Steven M; Pauliks, Linda B

    2016-08-16

    A 15-year-old boy with transposition of the great arteries (TGA) and neonatal arterial switch operation (ASO) presented with complete occlusion of the left main coronary artery (LMCA). Intra-operatively, an intramural left coronary artery was identified. Therefore, since age 7 years he had a series of screening exercise stress tests. At 13 years old, he had 3 to 4 mm ST segment depression in the infero-lateral leads without symptoms. This progressed to 4.2 mm inferior ST segment depression at 15 years old with normal stress echocardiogram. Sestamibi myocardial perfusion scan and cardiac magnetic resonance imaging was inconclusive. Therefore, a coronary angiogram was obtained which showed complete occlusion of the LMCA with ample collateralization from the right coronary artery system. This was later confirmed on a computed tomogram (CT) angiogram, obtained in preparation of coronary artery bypass grafting. The case illustrates the difficulty of detecting coronary artery stenosis and occlusion in young patients with rich collateralization. Coronary CT angiogram and conventional angiography were the best imaging modalities to detect coronary anomalies in this adolescent with surgically corrected TGA. Screening CT angiography may be warranted for TGA patients, particularly for those with known coronary anomalies. PMID:27574609

  6. Coronary artery occlusion after arterial switch operation in an asymptomatic 15-year-old boy

    PubMed Central

    Saini, Ashish P; Cyran, Stephen E; Ettinger, Steven M; Pauliks, Linda B

    2016-01-01

    A 15-year-old boy with transposition of the great arteries (TGA) and neonatal arterial switch operation (ASO) presented with complete occlusion of the left main coronary artery (LMCA). Intra-operatively, an intramural left coronary artery was identified. Therefore, since age 7 years he had a series of screening exercise stress tests. At 13 years old, he had 3 to 4 mm ST segment depression in the infero-lateral leads without symptoms. This progressed to 4.2 mm inferior ST segment depression at 15 years old with normal stress echocardiogram. Sestamibi myocardial perfusion scan and cardiac magnetic resonance imaging was inconclusive. Therefore, a coronary angiogram was obtained which showed complete occlusion of the LMCA with ample collateralization from the right coronary artery system. This was later confirmed on a computed tomogram (CT) angiogram, obtained in preparation of coronary artery bypass grafting. The case illustrates the difficulty of detecting coronary artery stenosis and occlusion in young patients with rich collateralization. Coronary CT angiogram and conventional angiography were the best imaging modalities to detect coronary anomalies in this adolescent with surgically corrected TGA. Screening CT angiography may be warranted for TGA patients, particularly for those with known coronary anomalies. PMID:27574609

  7. Systematic Assessment of the Various Controversies, Difficulties, and Current Trends in the Reestablishment of Lost Occlusal Planes in Edentulous Patients

    PubMed Central

    Sahoo, S; Singh, D; Raghav, D; Singh, G; Sarin, A; Kumar, P

    2014-01-01

    Accurate occlusal plane orientation is an essential factor in the fabrication of complete denture prosthesis. Over the years, it has received a number of methodologies by several researchers utilizing various anatomical landmarks however none of them is considered as perfect that could orient ideal occlusal plane. The presented literature review is an attempt to enlighten historical perspectives, pioneer researches, different controversies, difficulties and current trends for re-establishment of lost occlusal plane in edentulous patients. An extensive literature search was performed using Medline/PubMed interface and other scholarly research bibliographic databases using Medical Subject Headings. Studies describing research studies, case series and assorted clinical reports were retrieved and evaluated from 1963 to 2013. Most of the studies have suggest and evidence to consider Camper's plane for artificial orientation of occlusal plane however there is a substantial lack of genuine long term studies and authentic data that could recommend a single reliable landmark for perfect occlusal plane reorientation in a variety of cases. PMID:24971200

  8. Modified Occlusal Table - An Aid to Enhance Function of Hemimandibulectomy Patient: A Case Report

    PubMed Central

    Thippanna, Roopa Kundur; Dang, Krutika; Hajira, Neha; Sharma, Atulya

    2015-01-01

    Completely edentulous patients who have undergone hemimandibulectomy suffer severe anatomic and functional loss. Functions like mastication, speech and deglutition are severely compromised. The mandibular deviation towards the resected side leads to inefficient mastication. In order to alleviate the difficulties encountered by the patient, construction of a modified occlusal table into conventional complete denture has been described in this article. This simple modification enables the patient to articulate teeth on a broader surface area. The inclines of the cusps also help in mandibular guidance. Thus, prosthetic rehabilitation of hemimandibulectomy patients with two rows of teeth on the unresected side serves to restore function and aaesthetics providing them with an added psychological comfort. PMID:26501024

  9. Sharp Recanalization for Chronic Left Iliac Vein Occlusion

    SciTech Connect

    Ito, Nobutake Isfort, Peter; Penzkofer, Tobias; Grommes, Jochen; Greiner, Andreas; Mahnken, Andreas

    2012-08-15

    Endovascular treatment has emerged as a first-line treatment for venous occlusions, but is sometimes challenging with conventional approaches. This article describes a helpful technique using a Roesch-Uchida needle to cross a chronic occlusion of the iliac vein when conventional techniques have failed.

  10. The Effect of Occlusion on Motion Integration in Infants

    ERIC Educational Resources Information Center

    Otsuka, Yumiko; Konishi, Yukuo; Kanazawa, So; Yamaguchi, Masami K.

    2009-01-01

    Previous psychophysical studies have shown that the adult human visual system makes use of form information such as occlusion to determine whether to integrate or segregate local motion signals (J. McDermott, Y. Weiss, & E. H. Adelson, 2001). Using the displays developed by McDermott et al., these experiments examined whether occlusion and amodal…

  11. Effect of glove occlusion on the skin barrier.

    PubMed

    Tiedemann, Daniel; Clausen, Maja Lisa; John, Swen Malthe; Angelova-Fischer, Irena; Kezic, Sanja; Agner, Tove

    2016-01-01

    Wet work tasks are the most common exposures leading to occupational irritant contact dermatitis. Use of liquid-proof gloves is recommended when performing wet work, however, gloves may also contribute to impairment of the skin barrier and development of irritant contact dermatitis. The aim of this study is to review the literature on the effects of glove occlusion on skin barrier function. The PubMed database was searched up to 1 February 2015 for articles on the association between glove occlusion and skin barrier function, including human studies only and in English. Only experimental studies including assessment of the skin barrier function were included in the data analysis. Thirteen articles were identified, 8 with focus on occlusion alone, 7 with focus on occlusion in combination with irritant exposure (some overlapping), and 2 field studies. In conclusion, data from the literature showed that the negative effect of occlusion in itself is limited, and that only extensive and long-term occlusion will cause barrier impairment. However, studies investigating combined effect of occlusion and exposure to soaps/detergents indicate that occlusion significantly enhances the skin barrier damage caused by detergents/soaps in a dose-response fashion. PMID:26364588

  12. 21 CFR 870.2890 - Vessel occlusion transducer.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Vessel occlusion transducer. 870.2890 Section 870... transducer. (a) Identification. A vessel occlusion transducer is a device used to provide an electrical..., sound, and ultrasonic transducers. (b) Classification. Class II (performance standards)....

  13. 21 CFR 870.2890 - Vessel occlusion transducer.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Vessel occlusion transducer. 870.2890 Section 870... transducer. (a) Identification. A vessel occlusion transducer is a device used to provide an electrical..., sound, and ultrasonic transducers. (b) Classification. Class II (performance standards)....

  14. 21 CFR 870.2890 - Vessel occlusion transducer.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Vessel occlusion transducer. 870.2890 Section 870... transducer. (a) Identification. A vessel occlusion transducer is a device used to provide an electrical..., sound, and ultrasonic transducers. (b) Classification. Class II (performance standards)....

  15. 21 CFR 870.2890 - Vessel occlusion transducer.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Vessel occlusion transducer. 870.2890 Section 870... transducer. (a) Identification. A vessel occlusion transducer is a device used to provide an electrical..., sound, and ultrasonic transducers. (b) Classification. Class II (performance standards)....

  16. 21 CFR 870.2890 - Vessel occlusion transducer.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Vessel occlusion transducer. 870.2890 Section 870... transducer. (a) Identification. A vessel occlusion transducer is a device used to provide an electrical..., sound, and ultrasonic transducers. (b) Classification. Class II (performance standards)....

  17. Guide wire extension for shape memory polymer occlusion removal devices

    DOEpatents

    Maitland, Duncan J.; Small, IV, Ward; Hartman, Jonathan

    2009-11-03

    A flexible extension for a shape memory polymer occlusion removal device. A shape memory polymer instrument is transported through a vessel via a catheter. A flexible elongated unit is operatively connected to the distal end of the shape memory polymer instrument to enhance maneuverability through tortuous paths en route to the occlusion.

  18. Relationship between retinal vascular occlusions and incident cerebrovascular diseases

    PubMed Central

    Zhou, Yue; Zhu, Wengen; Wang, Changyun

    2016-01-01

    Abstract Several studies investigating the role of retinal vascular occlusions, on cerebrovascular diseases (CVD) have been reported, but the results are still inconsistent. We therefore sought to evaluate the relationship between retinal vascular occlusions and CVD. We systematically searched the Cochrane Library, PubMed, and ScienceDirect databases through January 31, 2016 for studies evaluating the effect of retinal vascular occlusions on the risk of CVD. Data were abstracted using predefined criteria, and then pooled by RevMan 5.3 software. A total of 9 retrospective studies were included in this meta-analysis. When compared with individuals without retinal vascular occlusions, both individuals with retinal artery occlusion (RAO) (odds ratio [OR] = 2.01, 95% confidence interval [CI]: 1.21–3.34; P = 0.005) and individuals with retinal vein occlusion (RVO) (OR = 1.37, 95% CI: 1.24–1.50; P < 0.00001) had higher risks of developing CVD. Additionally, both individuals with central retinal artery occlusion (CRAO) (OR = 2.00, 95% CI: 1.12–3.56; P = 0.02) and branch retinal artery occlusion (BRAO) (OR = 1.60, 95% CI: 1.03–1.48; P = 0.04) were significantly associated with increased risk of CVD. Published literatures support both RVO and RAO are associated with increased risks of CVD. Further prospective studies are needed to confirm these findings. PMID:27368050

  19. Emergency placement of stent-graft for symptomatic acute carotid artery occlusion after endarterectomy.

    PubMed

    Ko, Jun Kyeung; Choi, Chang Hwa; Lee, Sang Weon; Lee, Tae Hong

    2015-01-01

    A patient underwent a left-sided carotid endarterectomy (CEA) for an asymptomatic 80% carotid artery (CA) stenosis. There were no signs of intolerance during the carotid cross-clamping and an initially uneventful awakening was observed. However, in the third postoperative hour he experienced left amaurosis and dysarthria. An urgent MRI showed an occluded internal CA on the operated site without evidence of acute infarction. To recanalize the occluded internal CA and minimize leakage from the arteriotomy site, a self-expandable stent-graft was placed, covering the dissection and the distal atherosclerotic lesions. Complete recanalization of the left internal CA was achieved and the patient showed a dramatic improvement of his preoperative deficits. To our knowledge, this is the first case of stent-graft implantation for a symptomatic acute CA occlusion following CEA. Stent-graft placement should be considered as an alternative method of treatment for acute CA occlusion or dissection following CEA. PMID:25636626

  20. Emergency placement of stent-graft for symptomatic acute carotid artery occlusion after endarterectomy.

    PubMed

    Ko, Jun Kyeung; Choi, Chang Hwa; Lee, Sang Weon; Lee, Tae Hong

    2016-03-01

    A patient underwent a left-sided carotid endarterectomy (CEA) for an asymptomatic 80% carotid artery (CA) stenosis. There were no signs of intolerance during the carotid cross-clamping and an initially uneventful awakening was observed. However, in the third postoperative hour he experienced left amaurosis and dysarthria. An urgent MRI showed an occluded internal CA on the operated site without evidence of acute infarction. To recanalize the occluded internal CA and minimize leakage from the arteriotomy site, a self-expandable stent-graft was placed, covering the dissection and the distal atherosclerotic lesions. Complete recanalization of the left internal CA was achieved and the patient showed a dramatic improvement of his preoperative deficits. To our knowledge, this is the first case of stent-graft implantation for a symptomatic acute CA occlusion following CEA. Stent-graft placement should be considered as an alternative method of treatment for acute CA occlusion or dissection following CEA. PMID:25653229

  1. [A Case of Acute Arterial Occlusion of the Lower Limb during Chemotherapy for Lung Cancer].

    PubMed

    Tanaka, Kentaro; Takada, Kazuto; Kojima, Eiji; Shimizu, Takahiro; Miyamatsu, Shohko; Nohara, Kango; Sakurai, Tsutomu; Mizuno, Takaaki; Yamashita, Yuuki

    2016-05-01

    A 69-year-old man visited a clinic for left leg weakness. With suspicions of lung cancer and a metastatic brain tumor, he was referred to our hospital and was diagnosed with large cell neuroendocrine carcinoma, cT1bN0M1b (BRA), stage IV. After stereotactic radiosurgery for his brain metastasis, he was treated with chemotherapy containing cisplatin and irinotecan. A week after initiating chemotherapy, he suddenly developed severe right leg pain and adynamia. A computed tomography angiogram revealed occlusion of the right common femoral artery, and percutaneous thrombectomy was performed. The symptoms resolved completely, and he was discharged without any sequelae or recurrence. Acute arterial occlusion of the limbs during chemotherapy is uncommon and requires prompt diagnosis and treatment; hence, caution should be paid when it is clinically suspected. PMID:27210093

  2. Pancreaticoduodenal artery aneurysm associated with coeliac artery occlusion from an aortic intramural hematoma

    PubMed Central

    Sakatani, Akihiko; Doi, Yoshinori; Kitayama, Toshiaki; Matsuda, Takaaki; Sasai, Yasutaka; Nishida, Naohiro; Sakamoto, Megumi; Uenoyama, Naoto; Kinoshita, Kazuo

    2016-01-01

    Pancreaticoduodenal artery aneurysms are a rare type of visceral artery aneurysm, whose rupture is associated with high mortality. These aneurysms are of particular interest because local haemodynamic change caused by coeliac artery obstruction plays an important role in their development. However, the pathophysiological mechanism of coeliac artery obstruction is not completely understood. Pressure from the median arcuate ligament is most frequently reported cause. Although it is well-known that stenosis or occlusion of the visceral vessels may be caused by aortic syndrome, reports of pancreaticoduodenal artery aneurysm associated with coeliac artery occlusion due to aortic syndrome are extremely rare. Our case indicates a new aetiology for a pancreaticoduodenal artery aneurysm and demonstrates the rapid deterioration of the patient affected. PMID:27122676

  3. Monofilament intraluminal middle cerebral artery occlusion in the mouse.

    PubMed

    Clark, W M; Lessov, N S; Dixon, M P; Eckenstein, F

    1997-12-01

    The rat middle cerebral artery (MCA) occlusion model with an intraluminal filament is well characterized with a two hour period of occlusion in widespread use. The recent availability of transgenic animals has led to an interest in adapting the MCA model in the mouse. To date the model has not been well characterized in the mouse. We performed the present study to compare different durations of MCA occlusion and to validate new functional assessments in this model. The MCA occlusion model (5-0 filament) was used. Swiss-Webster mice, 24-44 g, were randomly assigned to four groups: one hour of occlusion; two hours of occlusion; three hours of occlusion; or permanent occlusion. At 48 hours post-ischemia, the animals were rated on three neurologic function scales, and then the brains were removed for lesion size determination. Overall, there was a significant difference in lesion volume (p < 0.001) between the groups. In the permanent group of mice, the average lesion volume was 78.41 +/- 17.47 mm (n = 12); two and three hours of ischemia produced 51.29 +/- 29.82 mm3 (n = 11) and 54.85 mm3 (n = 13), respectively, significantly different than the one hour group 14.84 +/- 31.34 mm3 (n = 11). All three functional scoring systems found significant overall differences between the four groups with our detailed General and Focal scores producing more robust between group treatment differences and showing correlation coefficients of r = 0.766 and r = 0.788, respectively to infarct volume. The MCA filament occlusion model can be successfully adapted in the mouse with either two or three hour occlusions producing reliable infarcts. New functional scoring systems unique to the mouse appear to add additional information. PMID:9427967

  4. Robust visual tracking with contiguous occlusion constraint

    NASA Astrophysics Data System (ADS)

    Wang, Pengcheng; Qian, Weixian; Chen, Qian

    2016-02-01

    Visual tracking plays a fundamental role in video surveillance, robot vision and many other computer vision applications. In this paper, a robust visual tracking method that is motivated by the regularized ℓ1 tracker is proposed. We focus on investigating the case that the object target is occluded. Generally, occlusion can be treated as some kind of contiguous outlier with the target object as background. However, the penalty function of the ℓ1 tracker is not robust for relatively dense error distributed in the contiguous regions. Thus, we exploit a nonconvex penalty function and MRFs for outlier modeling, which is more probable to detect the contiguous occluded regions and recover the target appearance. For long-term tracking, a particle filter framework along with a dynamic model update mechanism is developed. Both qualitative and quantitative evaluations demonstrate a robust and precise performance.

  5. Gastroesophageal reflux diagnosed by occlusal splint tintion.

    PubMed

    Cebrián-Carretero, José Luis; López-Arcas-Calleja, José María

    2006-01-01

    The gastroesophageal reflux (GER) disease is a very frequent digestive disorder, mainly characterised by the reflux of the gastric acidic content to the esophage in abnormal quantities. There are different situations that favour this situation but almost in all of them rely an incompetence of the esophagic sphincter. The clinical consequences are many, including oral manifestations. Among all of them the most frequent is the esophagitis followed by symptoms at the pharynx or larynx and finally, the oral cavity. At this level fundamentally we will find enamel and oral mucosa erosions. We report the case of a patient who was indirectly diagnosed of her esophague disease by the observation of the alterations in the occlusal splint induced by the gastric reflux. We review the literature concerning the above topic and its possible association with the miofascial syndrome. PMID:16388289

  6. Logic-controlled occlusive cuff system

    NASA Technical Reports Server (NTRS)

    Baker, J. T.; Hoffler, G. W. (Inventor); Hursta, W. N.

    1981-01-01

    An occlusive cuff system comprises a pressure cuff and a source of regulated compressed gas feeding the cuff through an electrically operated fill valve. An electrically operated vent valve vents the cuff to the ambient pressure. The fill valve is normally closed and the vent valve is normally open. In response to an external start signal, a logic network opens the fill valve and closes the vent valve, thereby starting the pressurization cycle and a timer. A pressure transducer continuously monitors the pressure in the cuff. When the transducer's output equals a selected reference voltage, a comparator causes the logic network to close the fill valve. The timer, after a selected time delay, opens the vent valve to the ambient pressure, thereby ending the pressurization cycle.

  7. Prosthetic occlusive device for an internal passageway

    NASA Technical Reports Server (NTRS)

    Tenney, J. B., Jr. (Inventor)

    1983-01-01

    An occlusive device is disclosed for surgical implant to occlude the lumen of an internal organ. The device includes a cuff having a backing collar and two isolated cuff chambers. The fluid pressure of one chamber is regulated by a pump/valve reservoir unit. The other chamber is unregulated in pressure but its fluid volume is adjusted by removing or adding fluid to a septum/reservoir by means of a hypodermic needle. Pressure changes are transmitted between the two cuff chambers via faying surfaces which are sufficiently large in contact area and thin as to transmit pressure generally without attenuation. By adjusting the fluid volume of the septum, the operating pressure of the device may be adjusted to accommodate tubular organs of different diameter sizes as well as to compensate for changes in the organ following implant without reoperation.

  8. Acute Aortic Occlusion Presenting as Flaccid Paraplegia

    PubMed Central

    Kilany, Ayman; Al-Hashel, Jasem Y.; Rady, Azza

    2015-01-01

    A 67-year-old male known to be hypertensive and diabetic had a sudden onset of severe low back pain and flaccid paraplegia with no sensory level or bladder affection and the distal pulsations were felt. Acute compressive myelopathy was excluded by MRI of the dorsal and lumbar spines. The nerve conduction study and CSF analysis was suggestive of acute demyelinating polyneuropathy. The patient developed ischemic changes of the lower limb and CT angiography revealed severe stenosis of the abdominal aorta and both common iliac arteries. We emphasize the importance of including acute aortic occlusion in the differential diagnosis of acute flaccid paraplegia especially in the presence of severe back pain even if the distal pulsations were felt. PMID:25866688

  9. Central retinal vein occlusion and pseudoexfoliation syndrome

    PubMed Central

    Karagiannis, Dimitrios; Kontadakis, Georgios A; Klados, Nektarios E; Tsoumpris, Ioannis; Kandarakis, Artemios S; Parikakis, Efstratios A; Georgalas, Ilias; Tsilimbaris, Miltiadis K

    2015-01-01

    Purpose The purpose of this study was to investigate the existence of pseudoexfoliation syndrome (PXF) as a risk factor for the development of central retinal vein occlusion (CRVO). Methods This was a retrospective, comparative study of the prevalence of pseudoexfoliation in three groups of patients: 48 patients with CRVO, 164 patients with branch retinal vein occlusion (BRVO), and 70 control patients (70 eyes). All patients were phakic and had no previous diagnosis of glaucoma. Patients were matched in terms of age and systemic hypertension. All patients had normal intraocular pressure (IOP) at presentation (defined as less than or equal to 21 mmHg). Results In the CRVO group, 14 out of 48 patients were diagnosed as having PXF (29.17%). In the BRVO group, 14 out of 164 patients had PXF (8.5%), and in the control group, six out of 70 patients had PXF (8.6%). Differences of percentage between groups were statistically significant (P<0.001, χ2 test). When comparing patient subgroup with ischemic CRVO with subgroup with non-ischemic CRVO, we found that in the ischemic CRVO group, 13 out of 27 patients were diagnosed as having PXF (48.15%), and in the non-ischemic CRVO group, one out of 21 patients was diagnosed as having PXF (4.7%; P<0.001, χ2 test). The relative odds of having CRVO in patients with PXF versus patients without PXF were 4.406 (confidence interval [CI], 2.03–9.54). Conclusion PXF and CRVO, especially ischemic, are strongly associated in our study. Our results indicate that PXF might be an independent factor for CRVO, as it is related with CRVO independently from glaucoma. PMID:26056437

  10. Coherent spatial and temporal occlusion generation

    NASA Astrophysics Data System (ADS)

    Klein Gunnewiek, R.; Berretty, R.-P. M.; Barenbrug, B.; Magalhães, J. P.

    2009-02-01

    A vastly growing number of productions from the entertainment industry are aiming at 3D movie theatres. These productions use a two-view format, primarily intended for eye-wear assisted viewing in a well defined environment. To get this 3D content into the home environment, where a large variety of 3D viewing conditions exists (e.g different display sizes, display types, viewing distance), we need a flexible 3D format that can adjust the depth effect. Such a format is the image plus depth format in which a video frame is enriched with depth information of all pixels in the video. This format can be extended with an additional layer for occluded video and associated depth, that contains what is behind objects in the video. To produce 3D content in this extended format, one has to deduce what is behind objects. There are various axes along which this occluded data can be obtained. This paper presents a method to automatically detect and fill the occluded areas exploiting the temporal axis. To get visually pleasing results, it is of utmost importance to make the inpainting globally consistent. To do so, we start by analyzing data along the temporal axis and compute a confidence for each pixel. Then pixels from the future and the past that are not visible in the current frame are weighted and accumulated based on computed confidences. These results are then fed to a generic multi-source framework that computes the occlusion layer based on the available confidences and occlusion data.

  11. Membrane stabilizer

    DOEpatents

    Mingenbach, William A.

    1988-01-01

    A device is provided for stabilizing a flexible membrane secured within a frame, wherein a plurality of elongated arms are disposed radially from a central hub which penetrates the membrane, said arms imposing alternately against opposite sides of the membrane, thus warping and tensioning the membrane into a condition of improved stability. The membrane may be an opaque or translucent sheet or other material.

  12. Complete Makeover

    NASA Technical Reports Server (NTRS)

    2004-01-01

    [figure removed for brevity, see original site]

    Released July 23, 2004 The atmosphere of Mars is a dynamic system. Water-ice clouds, fog, and hazes can make imaging the surface from space difficult. Dust storms can grow from local disturbances to global sizes, through which imaging is impossible. Seasonal temperature changes are the usual drivers in cloud and dust storm development and growth.

    Eons of atmospheric dust storm activity has left its mark on the surface of Mars. Dust carried aloft by the wind has settled out on every available surface; sand dunes have been created and moved by centuries of wind; and the effect of continual sand-blasting has modified many regions of Mars, creating yardangs and other unusual surface forms.

    We finish our look at Mars's dynamic atmosphere with an image of the surface that has been completely modified by the wind. Even the small ridges that remain have been ground down to a cliff-face with a 'tail' of eroded material. The crosshatching shows that the wind regime has remained mainly E/W to ENE/WSW.

    Image information: VIS instrument. Latitude 8.9, Longitude 221 East (139 West). 19 meter/pixel resolution.

    Note: this THEMIS visual image has not been radiometrically nor geometrically calibrated for this preliminary release. An empirical correction has been performed to remove instrumental effects. A linear shift has been applied in the cross-track and down-track direction to approximate spacecraft and planetary motion. Fully calibrated and geometrically projected images will be released through the Planetary Data System in accordance with Project policies at a later time.

    NASA's Jet Propulsion Laboratory manages the 2001 Mars Odyssey mission for NASA's Office of Space Science, Washington, D.C. The Thermal Emission Imaging System (THEMIS) was developed by Arizona State University, Tempe, in collaboration with Raytheon Santa Barbara Remote Sensing. The THEMIS investigation is led by Dr. Philip

  13. Occlusal adjustment using the bite plate-induced occlusal position as a reference position for temporomandibular disorders: a pilot study

    PubMed Central

    2010-01-01

    Background Many researchers have not accepted the use of occlusal treatments for temporomandibular disorders (TMDs). However, a recent report described a discrepancy between the habitual occlusal position (HOP) and the bite plate-induced occlusal position (BPOP) and discussed the relation of this discrepancy to TMD. Therefore, the treatment outcome of evidence-based occlusal adjustments using the bite plate-induced occlusal position (BPOP) as a muscular reference position should be evaluated in patients with TMD. Methods The BPOP was defined as the position at which a patient voluntarily closed his or her mouth while sitting in an upright posture after wearing an anterior flat bite plate for 5 minutes and then removing the plate. Twenty-one patients with TMDs underwent occlusal adjustment using the BPOP. The occlusal adjustments were continued until bilateral occlusal contacts were obtained in the BPOP. The treatment outcomes were evaluated using the subjective dysfunction index (SDI) and the Helkimo Clinical Dysfunction Index (CDI) before and after the occlusal adjustments; the changes in these two indices between the first examination and a one-year follow-up examination were then analyzed. In addition, the difference between the HOP and the BPOP was three-dimensionally measured before and after the treatment. Results The percentage of symptom-free patients after treatment was 86% according to the SDI and 76% according to the CDI. The changes in the two indices after treatment were significant (p < 0.001). The changes in the mean HOP-BPOP differences on the x-axis (mediolateral) and the y-axis (anteroposterior) were significant (p < 0.05), whereas the change on the z-axis (superoinferior) was not significant (p > 0.1). Conclusion Although the results of the present study should be confirmed in other studies, a randomized clinical trial examining occlusal adjustments using the BPOP as a reference position appears to be warranted. PMID:20346167

  14. Complete denture covering mandibular tori using three base materials: a case report.

    PubMed

    Abrams, S

    2000-10-01

    The torus mandibularis presents many challenges when fabricating a complete denture. The mucosa tends to be thin and will not tolerate normal occlusal loads on a denture. Large mandibular tori can prevent complete seating of impression trays and denture. To address this problem, we fabricated a new mandibular complete denture incorporating a combination of soft acrylic flanges and liners. PMID:11070628

  15. Mitral Isthmus Ablation with and Without Temporary Spot Occlusion of the Coronary Sinus

    PubMed Central

    HOCINI, MÉLÈZE; SHAH, ASHOK J.; NAULT, ISABELLE; RIVARD, LENA; LINTON, NICK; NARAYAN, SANJIV; MIYAZAKI, SHINSUKE; JADIDI, AMIR S.; KNECHT, SÉBASTIEN; SCHERR, DANIEL; WILTON, STEPHEN B.; ROTEN, LAURENT; PASCALE, PATRIZIO; PEDERSEN, MICHALA; DERVAL, NICOLAS; SACHER, FRÉDÉRIC; JAÏS, PIERRE; CLÉMENTY, JACQUES; HAÏSSAGUERRE, MICHEL

    2012-01-01

    Objective To evaluate the safety and outcomes of mitral isthmus (MI) linear ablation with temporary spot occlusion of the coronary sinus (CS). Background CS blood flow cools local tissue precluding transmurality and bidirectional block across MI lesion. Methods In a randomized, controlled trial (CS-occlusion = 20, Control = 22), MI ablation was performed during continuous CS pacing to monitor the moment of block. CS was occluded at the ablation site using 1 cm spherical balloon, Swan–Ganz catheter with angiographic confirmation. Ablation was started at posterior mitral annulus and continued up to left inferior pulmonary vein (LIPV) ostium using an irrigated-tip catheter. If block was achieved, balloon was deflated and linear block confirmed. If not, additional ablation was performed epicardially (power ≤25 W). Ablation was abandoned after ~30 minutes, if block was not achieved. Results CS occlusion (mean duration –27 ± 9 minutes) was achieved in all cases. Complete MI block was achieved in 13/20 (65%) and 15/22 (68%) patients in the CS-occlusion and control arms, respectively, P = 0.76. Block was achieved with significantly small number (0.5 ± 0.8 vs 1.9 ± 1.1, P = 0.0008) and duration (1.2 ± 1.7 vs 4.2 ± 3.5 minutes, P = 0.009) of epicardial radiofrequency (RF) applications and significantly lower amount of epicardial energy (1.3 ± 2.4 vs 6.3 ± 5.7 kJ, P = 0.006) in the CS-occlusion versus control arm, respectively. There was no difference in total RF (22 ± 9 vs 23 ± 11 minutes, P = 0.76), procedural (36 ± 16 vs 39 ± 20 minutes, P = 0.57), and fluoroscopic (13 ± 7 vs 15 ± 10 minutes, P = 0.46) durations for MI ablation between the 2 arms. Clinically uneventful CS dissection occurred in 1 patient Conclusions Temporary spot occlusion of CS is safe and significantly reduces the requirement of epicardial ablation to achieve MI block. It does not improve overall procedural success rate and procedural duration. Tissue cooling by CS blood flow is just

  16. Biomechanics of occlusion--implications for oral rehabilitation.

    PubMed

    Peck, C C

    2016-03-01

    The dental occlusion is an important aspect of clinical dentistry; there are diverse functional demands ranging from highly precise tooth contacts to large crushing forces. Further, there are dogmatic, passionate and often diverging views on the relationship between the dental occlusion and various diseases and disorders including temporomandibular disorders, non-carious cervical lesions and tooth movement. This study provides an overview of the biomechanics of the masticatory system in the context of the dental occlusion's role in function. It explores the adaptation and precision of dental occlusion, its role in bite force, jaw movement, masticatory performance and its influence on the oro-facial musculoskeletal system. Biomechanics helps us better understand the structure and function of biological systems and consequently an understanding of the forces on, and displacements of, the dental occlusion. Biomechanics provides insight into the relationships between the dentition, jaws, temporomandibular joints, and muscles. Direct measurements of tooth contacts and forces are difficult, and biomechanical models have been developed to better understand the relationship between the occlusion and function. Importantly, biomechanical research will provide knowledge to help correct clinical misperceptions and inform better patient care. The masticatory system demonstrates a remarkable ability to adapt to a changing biomechanical environment and changes to the dental occlusion or other components of the musculoskeletal system tend to be well tolerated. PMID:26371622

  17. Accurate and occlusion-robust multi-view stereo

    NASA Astrophysics Data System (ADS)

    Zhu, Zhaokun; Stamatopoulos, Christos; Fraser, Clive S.

    2015-11-01

    This paper proposes an accurate multi-view stereo method for image-based 3D reconstruction that features robustness in the presence of occlusions. The new method offers improvements in dealing with two fundamental image matching problems. The first concerns the selection of the support window model, while the second centers upon accurate visibility estimation for each pixel. The support window model is based on an approximate 3D support plane described by a depth and two per-pixel depth offsets. For the visibility estimation, the multi-view constraint is initially relaxed by generating separate support plane maps for each support image using a modified PatchMatch algorithm. Then the most likely visible support image, which represents the minimum visibility of each pixel, is extracted via a discrete Markov Random Field model and it is further augmented by parameter clustering. Once the visibility is estimated, multi-view optimization taking into account all redundant observations is conducted to achieve optimal accuracy in the 3D surface generation for both depth and surface normal estimates. Finally, multi-view consistency is utilized to eliminate any remaining observational outliers. The proposed method is experimentally evaluated using well-known Middlebury datasets, and results obtained demonstrate that it is amongst the most accurate of the methods thus far reported via the Middlebury MVS website. Moreover, the new method exhibits a high completeness rate.

  18. Incidence and Predictors of Radial Artery Occlusion Associated Transradial Catheterization

    PubMed Central

    Tuncez, Abdullah; Kaya, Zeynettin; Aras, Dursun; Yıldız, Abdulkadir; Gül, Enes Elvin; Tekinalp, Mehmet; Karakaş, Mehmet Fatih; Kısacık, Halil Lütfü

    2013-01-01

    In this study, we sought to assess the incidence and predictors of radial artery occlusion (RAO), which is a significant complication of transradial cardiac catheterization. We prospectively evaluated the results of 106 patients who underwent coronary angiography and percutaneous coronary intervention (PCI) via the transradial approach (TRA). At the 3rd h of intervention, the radial artery was checked by palpation; color doppler ultrasonography was performed at the 24th h. Fluoroscopy duration, procedure success, and complications of the radial artery were recorded. The procedure was successfully completed in all patients. RAO was detected in eight female and two male patients. In terms of RAO, there was a statistically significant difference between males and females (p=0.019). Other parameters did not show a significant correlation with RAO. Altough did not have any effect on procedural success, eight patients developed transient radial artery spasm. Gender was not associated with radial arterial spasms (p=0.19). TRA in the diagnosis and treatment of coronary artery disease has shown high procedural success and low complication rates; it addition, it presents a low economic burden. It should be used widely and be involved in the routine cardiology residency program. PMID:24151442

  19. The challenge of basilar artery occlusion wake-up stroke: too late for intravenous thrombolysis?

    PubMed

    Caliandro, Pietro; Reale, Giuseppe; Tartaglione, Tommaso; Rossini, Paolo Maria

    2016-07-01

    We describe the case of a patient carried to our emergency department, with the wake-up finding of dysarthria, right hemiplegia and worsening consciousness impairment (NIHSS 12). After performing a CT angiography, which showed complete basilar occlusion, we determined the MR DWI-FLAIR mismatch to estimate the stroke onset time. Because of the favorable mismatch (DWI hyperintensity in the left pons, no FLAIR hyperintensity in the same region), the patient underwent thrombolysis with sudden neurological improvement. In addition, the DWI hyperintensity first observed in the left pons totally regressed after thrombolysis. Wake-up stroke constitutes about 14 % of all strokes, while the percentage of basilar artery occlusion wake-up strokes is still unknown. Although thrombolysis in patients with unknown-onset time is still an off-label therapy, basilar artery occlusion is a potentially fatal event. In our case we used RM DWI-FLAIR mismatch to rapidly estimate the stroke onset time and to treat the patient with an off-label but potentially effective and safe therapy. PMID:26960980

  20. Marvels, Mysteries, and Misconceptions of Vascular Compensation to Peripheral Artery Occlusion

    PubMed Central

    ZIEGLER, MATTHEW A.; DISTASI, MATTHEW R.; BILLS, RANDALL G.; MILLER, STEVEN J.; ALLOOSH, MOUHAMAD; MURPHY, MICHAEL P.; AKINGBA, A. GEORGE; STUREK, MICHAEL; DALSING, MICHAEL C.; UNTHANK, JOSEPH L.

    2010-01-01

    Peripheral arterial disease is a major health problem and there is a significant need to develop therapies to prevent its progression to claudication and critical limb ischemia. Promising results in rodent models of arterial occlusion have generally failed to predict clinical success and led to questions of their relevance. While sub-optimal models may have contributed to the lack of progress, we suggest that advancement has also been hindered by misconceptions of the human capacity for compensation and the specific vessels which are of primary importance. We present and summarize new and existing data from humans, Ossabaw miniature pigs, and rodents which provide compelling evidence that natural compensation to occlusion of a major artery (i) may completely restore perfusion, (ii) occurs in specific pre-existing small arteries, rather than the distal vasculature, via mechanisms involving flow-mediated dilation and remodeling (iii) is impaired by cardiovascular risk factors which suppress the flow-mediated mechanisms and (iv) can be restored by reversal of endothelial dysfunction. We propose that restoration of the capacity for flow-mediated dilation and remodeling in small arteries represents a largely unexplored potential therapeutic opportunity to enhance compensation for major arterial occlusion and prevent the progression to critical limb ischemia in the peripheral circulation. PMID:20141596

  1. Occlusal traits of deciduous dentition of preschool children of Indian children

    PubMed Central

    Bahadure, Rakesh N.; Thosar, Nilima; Gaikwad, Rahul

    2012-01-01

    Objectives: To assess the occlusal relationship, canine relationship, crowding, primate spaces, and anterior spacing in both maxillary and mandibular arches of primary dentition of Indian children of Wardha District and also to study the age-wise differences in occlusal characteristics. Materials and Methods: A total of 1053 (609 males and 444 females) children of 3-5 year age group with complete primary dentition were examined for occlusal relationship, canine relationship, crowding, primate spaces, and anterior spacing in both maxillary and mandibular arches. Results: The data after evaluation showed significant values for all parameters except mandibular anterior spacing, which was 47.6%. Mild crowding was prevalent at 5 year age group and moderate crowding was common at 3 year-age group. Conclusion: Evaluated parameters such as terminal molar relationship and canine relationship were predominantly progressing toward to normal but contacts and crowding status were contributing almost equal to physiologic anterior spacing. Five-year-age group showed higher values with respect to all the parameters. PMID:23633806

  2. The Benefits of Internal Thoracic Artery Catheterization in Patients With Chronic Abdominal Aortic Occlusion

    SciTech Connect

    Ilic, Nikola Davidovic, Lazar; Koncar, Igor; Dragas, Marko; Markovic, Miroslav; Colic, Momcilo; Cinara, Ilijas

    2011-04-15

    Occlusion of the abdominal aorta may be caused by an embolic lesion, but more commonly by thrombotic disease at the aortoiliac area, progressing retrograde. However, the visualization of the distal run-off via internal thoracic-epigastric inferior artery collateral channel may be a very important diagnostic tool, especially in countries with poor technical equipment. This study was designed to show the benefit of the selective internal thoracic angiography in cases with complete aortic occlusion. We present 30 patients with chronic aortic abdominal occlusion who were submitted to the transaxillary aortography and selective ITA angiography with purpose of distal run off evaluation. Angiographic evaluation was performed by two independent radiologists according to previously defined classification. Good angiographic score via internal thoracic angiography by first observer was achieved in 19 (63.3%) patients and in 18 (60%) by a second observer. Transaxillary aortography showed inferior results: good angiographic score by the first observer in six (20%) patients and by the second observer in three (3%) patients. Low extremity run-off is better visualized during internal thoracic angiography than during transaxillary aortography.

  3. Axillary Artery Access for Combined Endoaortic Balloon Occlusion and Perfusion During Robotic Mitral Valve Surgery.

    PubMed

    Ambur, Vishnu V; Kadakia, Sagar S; Taghavi, Sharven; Jayarajan, Senthil N; Kashem, Mohammed Abul; McCarthy, James; Shiose, Akira; Wheatley, Grayson H; Toyoda, Yoshiya; Guy, T Sloane

    2016-01-01

    We aimed to develop a method that provides an alternative cannulation site in robotic mitral valve surgery that allows simultaneous endo-occlusion and antegrade perfusion. A 71-year-old man with severe mitral regurgitation and history of coronary artery bypass grafting underwent totally endoscopic robotic mitral valve repair. A 23-mm endoreturn cannula was placed through a 10-mm graft that was sewn to the left axillary artery. An endoballoon was passed through the Dacron/cannula complex and into the ascending aorta. This complex was used for simultaneous antegrade perfusion, endoballoon occlusion, and antegrade cardioplegia. Completion transesophageal echocardiography showed no evidence of mitral regurgitation. The patient had an uneventful postoperative course and was doing well at his 2-month follow-up appointment. The left axillary artery is a viable option for simultaneous endoballoon occlusion, antegrade perfusion, and antegrade cardioplegia in robotic mitral valve surgery. This has the potential benefit of providing antegrade perfusion, which some studies have shown to be associated with a decreased risk of complications when compared with retrograde perfusion specifically in patients with severe peripheral vascular disease. PMID:27093272

  4. Memokath Metallic Stent in the Treatment of Transplant Kidney Ureter Stenosis or Occlusion

    SciTech Connect

    Boyvat, Fatih E-mail: boyvatf@yahoo.com; Aytekin, Cuneyt; Colak, Turan; Firat, Ali; Karakayali, Hamdi; Haberal, Mehmet

    2005-04-15

    Purpose. To determine the efficacy of the Memokath 051 stent (Engineers and Doctors, Hornbaek, Denmark) in the treatment of recurrent ureteral stenosis or occlusion in transplant kidneys. Methods. From October 1985 through January 2004, 1,131 renal transplantations were performed at our center. Four patients who developed recurrent renal transplant ureter obstruction had nephrostomy catheters placed. Antegrade pyelography showed ureteral stenosis in three cases and complete occlusion in one patient. In each case, a Memokath 051 stent was inserted via an antegrade approach. Mean follow-up was 20 months (range 18-21 months). Creatinine levels were measured and ultrasonography was performed during follow-up. Results. All stent procedures were technically successful. During follow-up, one stent migrated within 10 days after stent insertion and was removed cystoscopically. Another stent had to be removed in the 14th month due to resistant infection, and was replaced with a new Memokath 051 stent which remained patent for another 8 months. The other two stents were fully patent at the 18th and 21st month of follow-up, respectively. Conclusion. Placement of a Memokath 051 stent appears to be a promising treatment alternative to balloon dilation, double-J stents and open surgical intervention for ureteral stenosis or occlusion in kidney transplant recipients. Further study of larger series is necessary.

  5. Brief communication: Identification reassessment of the isolated tooth Krapina D58 through occlusal fingerprint analysis.

    PubMed

    Fiorenza, Luca; Benazzi, Stefano; Tausch, Jeremy; Kullmer, Ottmar; Schrenk, Friedemann

    2010-10-01

    High variability in the dentition of Homo can create uncertainties in the correct identification of isolated teeth. For instance, standard tooth identification criteria cannot determine with absolute certainty if an isolated tooth is a second or third maxillary molar. In this contribution, using occlusal fingerprint analysis, we reassess the identification of Krapina D58 (Homo neanderthalensis), which is catalogued as a third maxillary molar. We have hypothesized that the presence/absence of the distal occlusal wear facets can be used to differentiate second from third maxillary molars. The results obtained confirm our hypothesis, showing a significant difference between second and third maxillary molars. In particular we note the complete absence of Facets 7 and 10 in all third molars included in this analysis. The presence of these facets in Krapina D58 eliminates the possibility that it is a third maxillary molar. Consequently it should be reclassified as a second molar. Although this method is limited by the degree of dental wear (i.e., unworn teeth cannot be analyzed) and to individual molars in full occlusion, it can be used for tooth identification when other common criteria are not sufficient to discriminate between second and third maxillary molars. PMID:20853483

  6. Effect of Toll-Like Receptor 4 on Synovial Injury of Temporomandibular Joint in Rats Caused by Occlusal Interference

    PubMed Central

    Kong, Jingjing; Yang, Yingying; Sun, Shuzhen; Xie, Jianli; Lin, Xuefen; Ji, Ping

    2016-01-01

    Synovitis is an important disease that causes intractable pain in TMJ. Some investigations suggested that the increasing expression of IL-1β secreted by synovial lining cells plays an important role in synovial inflammation and cartilage destruction in TMJ. In our previous research, the results demonstrated that TLR4 is involved in the expression of IL-1β in SFs from TMJ with lipopolysaccharide stimulation. However, the inflammatory response that occurred in synovial membrane is not caused by bacterial infection. In the current study, we investigated whether or not TLR4 participates in the inflammatory responses and the expression of IL-1β in synovial membrane of rats induced by occlusal interference. The results showed that obvious inflammation changes were observed in the synovial membranes and the expression of TLR4 and IL-1β was increased at both mRNA and protein levels in the occlusal interference rats. In addition, the inflammation reactions and the increased expression of IL-1β could be restrained by treatment with TAK-242, a blocker of TLR4 signaling. The results prompted us that the activation of TLR4 may be involved in the inflammatory reactions and increased expression of IL-1β in patients with synovitis and participate in the mechanisms of the initiation and development of synovial injury by regulating the expression of inflammatory mediators like IL-1β in synovial membranes. PMID:27413256

  7. Complete denture fabrication supported by CAD/CAM.

    PubMed

    Wimmer, Timea; Gallus, Korbinian; Eichberger, Marlis; Stawarczyk, Bogna

    2016-05-01

    The inclusion of computer-aided design/computer-aided manufacturing (CAD/CAM) technology into complete denture fabrication facilitates the procedures. The presented workflow for complete denture fabrication combines conventional and digitally supported treatment steps for improving dental care. With the presented technique, the registration of the occlusal plane, the determination of the ideal lip support, and the verification of the maxillomandibular relationship record are considered. PMID:26774323

  8. Ocular neovascularization in eyes with a central retinal artery occlusion or a branch retinal artery occlusion

    PubMed Central

    Mason, John O; Patel, Shyam A; Feist, Richard M; Albert, Michael A; Huisingh, Carrie; McGwin, Gerald; Thomley, Martin L

    2015-01-01

    Purpose To investigate the ocular neovascularization (ONV) rate in eyes with a branch retinal artery occlusion (BRAO) or a central retinal artery occlusion (CRAO), and to study factors that may influence the ONV rate secondary to CRAO. Methods This was a retrospective case series of consecutive patients (286 total eyes: 83 CRAOs and 203 BRAOs) who were diagnosed with a retinal artery occlusion from 1998 to 2013 at the Retina Consultants of Alabama and University of Alabama at Birmingham, Birmingham, AL, USA. Generalized estimating equations were used to evaluate the association between hypothesized risk factors and ONV development. Results Twelve (14.5%) of the 83 eyes with a CRAO developed ONV. Eleven of 12 eyes (91.7%) had iris neovascularization, ten of 12 eyes (83.3%) had neovascular glaucoma, and two of 12 eyes (16.7%) had neovascularization of the optic disc. The average time for ONV development secondary to CRAO was 30.7 days, ranging from the date of presentation to 137 days. Only two (<1.0%) of the 203 eyes with a BRAO developed iris neovascularization. Diabetes mellitus type 2 was a risk factor for ONV development following a CRAO with an adjusted odds ratio of 5.2 (95% confidence interval: 1.4–19.8) (P=0.02). Conclusion ONV is an important complication of CRAO and is a less-frequent complication of BRAO. Patients with a CRAO, especially those with diabetes mellitus type 2, should be closely monitored for the first 6 months for ONV. PMID:26089631

  9. Avoiding occlusal derangement in facial fractures: An evidence based approach.

    PubMed

    Mendonca, Derick; Kenkere, Deepika

    2013-05-01

    Facial fractures with occlusal derangement describe any fracture which directly or indirectly affects the occlusal relationship. Such fractures include dento-alveolar fractures in the maxilla and mandible, midface fractures - Le fort I, II, III and mandible fractures of the symphysis, parasymphysis, body, angle, and condyle. In some of these fractures, the fracture line runs through the dento-alveolar component whereas in others the fracture line is remote from the occlusal plane nevertheless altering the occlusion. The complications that could ensue from the management of maxillofacial fractures are predominantly iatrogenic, and therefore can be avoided if adequate care is exercised by the operating surgeon. This paper does not emphasize on complications arising from any particular technique in the management of maxillofacial fractures but rather discusses complications in general, irrespective of the technique used. PMID:24501457

  10. Amplatzer vascular plug for rapid vessel occlusion in interventional neuroradiology.

    PubMed

    Banfield, Jillian C; Shankar, Jai Jai Shiva

    2016-02-01

    The purpose of this paper is to report different uses of endovascular Amplatzer vascular plug (AVP) treatment for rapid vessel occlusion in the field of interventional neuroradiology. We retrospectively reviewed our interventional neuroradiology database from November 2010 to July 2015 and found nine patients who were treated with endovascular AVP. AVP was used for rapid vessel occlusion of common carotid artery (1 patient), internal carotid artery (5 patients), vertebral artery (2 patients), and internal jugular vein (1 patient). A median of three AVPs were used with almost immediate occlusion and no thromboembolic complications. Use of AVP is feasible, safe, rapid, and potentially cost-effective method for rapid occlusion of larger size vessels in the head and neck region for different indications. PMID:26515699

  11. Endobronchial lipoma: a rare cause of bronchial occlusion.

    PubMed

    Triviño, Ana; Mora-Cabezas, Montserrat; Vallejo-Benitez, Ana; García-Escudero, Antonio; González-Cámpora, Ricardo

    2013-11-01

    Endobronchial lipoma is a rare benign neoplasm of the tracheobronchial tree. Despite its benign nature, associated endoluminal polypoid growth can cause bronchial occlusion. In this paper, we present the consequences of a late diagnosis of this condition. PMID:23680317

  12. Cerec: correlation, an accurate and practical method for occlusal reconstruction.

    PubMed

    Prévost, A P; Bouchard, Y

    2001-07-01

    The correlation technique explained here shows one of the possibilities for occlusal reconstruction offered by the Cerec approach. The various stages of this technique are described and illustrated. The most current applications are reviewed. PMID:11862885

  13. Height Gradient Approach for Occlusion Detection in Uav Imagery

    NASA Astrophysics Data System (ADS)

    Oliveira, H. C.; Habib, A. F.; Dal Poz, A. P.; Galo, M.

    2015-08-01

    The use of Unmanned Aerial Vehicle (UAV) significantly increased in the last years. It is used for several different applications, such as mapping, publicity, security, natural disasters assistance, environmental monitoring, 3D building model generation, cadastral survey, etc. The imagery obtained by this kind of system has a great potential. To use these images in true orthophoto generation projects related to urban scenes or areas where buildings are present, it is important to consider the occlusion caused by surface height variation, platform attitude, and perspective projection. Occlusions in UAV imagery are usually larger than in conventional airborne dataset due to the low-altitude and excessive change in orientation due to the low-weight and wind effects during the flight mission. Therefore, this paper presents a method for occlusion detection together with some obtained results for images acquired by a UAV platform. The proposed method shows potential in occlusion detection and true orthophoto generation.

  14. Occlusion of a wire-reinforced endotracheal tube in an almost completely edentulous patient.

    PubMed

    Haas, Richard E; Kervin, Matthew W; Ramos, Paula; Brown, Jerry

    2003-05-01

    Wire-reinforced endotracheal tubes have been advocated for use where endotracheal tube kinking is a risk. We report on a 79-year-old nearly edentulous male patient in a weakened state who managed to partially obstruct a wire-reinforced endotracheal tube, despite the presence of a soft bite block. The risk of kinking wire-reinforced endotracheal tubes is not mitigated simply because the patient is edentulous. Good monitoring, vigilance by providers and the use of a solid bite block remains critical in the care of these patients. PMID:12775182

  15. Pathophysiological aspects of sickle cell vaso-occlusion

    SciTech Connect

    Nagel, R.L.

    1987-01-01

    This book contains over 30 selections. Some of the titles are: An Animal Model for Sickle Cell Vaso-Occlusion: A Study Using NMR and Technetium Imaging; Sickle-Cell Vaso-Occlusion in an Animal Model: Intravital Microscopy and Radionuclide Imaging of Selective Sequestration of Dense Cells; Magnetic Resonance Imaging, Percentage of Dense Cells, and Serum Prostanoids as Tools for Objective Assessment of Pain Crisis: A Preliminary Report; and Painful Crisis and Dense Echinocytes: Effects of Hydration and Vasodilators.

  16. Chewing efficiency and occlusal functional morphology in modern humans.

    PubMed

    Laird, Myra F; Vogel, Erin R; Pontzer, Herman

    2016-04-01

    The reduction of occlusal dimensions in early Homo is often proposed to be a functional adaptation to diet. With their smaller occlusal surfaces, species of early Homo are suggested to have reduced food-processing abilities, particularly for foods with high material properties (e.g., increased toughness). Here, we employ chewing efficiency as a measure of masticatory performance to test the relationships between masticatory function and food properties. We predicted that humans are more efficient when processing foods of lower toughness and Young's modulus values, and that subjects with larger occlusal surfaces will be less efficient when processing foods with higher toughness and Young's modulus, as the greater area spreads out the overall bite force applied to food particles. Chewing efficiency was measured in 26 adults using high-speed motion capture and surface electromyography. The dentition of each subject was cast and the occlusal surface was quantified using dental topographic analysis. Toughness and displacement-limited index were negatively correlated with chewing efficiency, but Young's modulus was not. Increased occlusal two-dimensional area and surface area were positively correlated with chewing efficiency for all foods. Thus, larger occlusal surface areas were more efficient when processing foods of greater toughness. These results suggest that the reduction in occlusal area in early Homo was associated with a reduction in chewing efficiency, particularly for foods with greater toughness. Further, the larger occlusal surfaces of earlier hominins such as Australopithecus would have likely increased chewing efficiency and increased the probability of fracture when processing tough foods. PMID:27086052

  17. Inflammatory reaction as an occlusive mechanism in aortocoronary bypass grafts?

    PubMed

    Svendsen, E; Dalen, H; Moland, J; Engedal, H

    1986-01-01

    Morphological changes in aortocoronary vein grafts are described in two cases; one dying 5 hours post operatively and the other reoperated 8 months after aortocoronary bypass surgery for graft occlusion. Occlusive thrombi and fibrin deposition on the intimal surface and a focal inflammatory process in the wall of the vein grafts were found in the former. Thrombotic encrustation and organization similar to the manifestations of the thrombogenic theory of atherosclerosis were demonstrated in the latter. PMID:3489720

  18. Retino-choroidal ischemia in central retinal vein occlusion

    PubMed Central

    Hussain, Nazimul; Hussain, Anjli

    2014-01-01

    A 41-year-old gentleman with insulin dependent diabetes had decreased vision in the right eye due to non-ischemic central retinal vein occlusion with macular edema. One month following intravitreal ranibizumab, he developed retino-choroidal ischemia with further loss of vision. Authors show the fluorescein angiographic transition from non-ischemic central retinal vein occlusion to retino-choroidal ischemia. PMID:25473353

  19. Can traumatic occlusion cause endodontic problems? A case report.

    PubMed

    Indramohan, Jamuna; Neelakantan, Prasanna; Subba Rao, C V; Vasudevan, C

    2011-01-01

    Radicular cysts are commonly found odontogenic cysts in the jaws. The lesion is diagnosed mainly in young patients during the second decade of life. In the majority of cases, it is asymptomatic. This paper reports a rare case in which traumatic occlusion was identified as the etiology of a radicular cyst. Endodontic treatment was performed and the traumatic occlusion also was corrected. A six-month follow-up appointment found good healing of the periapical region. PMID:21903554

  20. Viral Membrane Scission

    PubMed Central

    Rossman, Jeremy S.; Lamb, Robert A.

    2014-01-01

    Virus budding is a complex, multistep process in which viral proteins make specific alterations in membrane curvature. Many different viral proteins can deform the membrane and form a budding virion, but very few can mediate membrane scission to complete the budding process. As a result, enveloped viruses have developed numerous ways of facilitating membrane scission, including hijacking host cellular scission machinery and expressing their own scission proteins. These proteins mediate scission in very different ways, though the biophysical mechanics underlying their actions may be similar. In this review, we explore the mechanisms of membrane scission and the ways in which enveloped viruses use these systems to mediate the release of budding virions. PMID:24099087

  1. Endovascular Treatment of Blunt Traumatic Abdominal Aortic Occlusion With Kissing Stent Placement

    SciTech Connect

    Idoguchi, Koji Yamaguchi, Masato; Okada, Takuya; Nomura, Yoshikatsu; Sugimura, Kazuro; Okita, Yutaka; Sugimoto, Koji

    2012-10-15

    Blunt traumatic abdominal aortic dissection is extremely rare and potentially deadly. We present the case of a 62-year-old man involved in a frontal car crash. After emergency undergoing laparotomy for bowel injuries, he was referred to our hospital due to acute ischemia of bilateral lower extremities on day 3 after the trauma. Computed tomography and aortography showed an aortobiiliac dissection with complete occlusion. This injury was successfully treated by endovascular treatment with 'kissing'-technique stent placement, which appears to be a safe, effective, and minimally invasive treatment.

  2. Occlusion and periodontal disease--where is the link?

    PubMed

    Fu, Jia Hui; Yap, Adrian U J

    2007-12-01

    The effect of occlusion on the periodontium has been the subject of much debate. Interest on this subject has decreased over the years but has been renewed with the popularity of implant dentistry. This paper reviews the literature and explores the relationship between trauma from occlusion with periodontal disease and peri-implant bone loss. With regards to periodontal disease, there are two schools of thought on the effect that trauma from occlusion has on the periodontium. One believes that trauma from occlusion is a co-destructive factor in the initiation and progression of periodontal disease. The other believes that it is not. Up till now, there are no conclusive explanations on the association between trauma from occlusion and periodontal disease. For dental implants, current literature suggests that there is an association between occlusal overloading and peri-implant bone loss even in the absence of inflammation. However, there is a need for more randomized clinical trials to validate this relationship. PMID:18472527

  3. [Occlusal overload--a risk factor in implant based prostheses].

    PubMed

    Dănilă, V; Augustin, M

    2010-01-01

    The aim of the study was to perform a review of the literature data in regard to the main causes leading to failure of the dental implants and subsequently, of the implant based prostheses. Besides biological risk factors as infection, occlusal overload is considered the main mechanical risk factor being responsible for weakening or fracturing of the fixation screws, fracturing of the prosthesis or even of the implants. Understanding the fundamental differences between the natural dental structures and the implants may lead to a rigorous occlusal control as a key factor to success of implant born prosthesis. Among these, the periodontal ligament is of outmost importance because it allows a physiological-functional adjustment of occlusal stress in the longitudinal axis of the natural teeth and adaptation to the occlusal stress changes. In conclusion, the absence of periodontal ligament may lead to occlusal overload and implant failure due to lack of adjustment of occlusal forces intensity and axial transmission of these forces, as well as the absence of periodontal proprioceptors. PMID:20509305

  4. The influence of stoma occlusion on aspects of tracheoesophageal voice.

    PubMed

    van As, C J; Hilgers, F J; Koopmans-van Beinum, F J; Ackerstaff, A H

    1998-09-01

    In this study, speech of 21 laryngectomized patients is investigated under 2 different stoma occlusion conditions, i.e. direct digital occlusion of the stoma (by thumb or finger), and digital occlusion (by finger) via a special heat and moisture exchanger with speech valve (Provox Stomafilter). For both conditions, acoustical analyses of voice quality (various pitch, amplitude, tremor and harmonicity measures) were performed on a sustained /a/, the mean maximum phonation time was calculated, and a phonetogram was made. Acoustical analysis was possible in 13 of the 21 voices (for the other voices, the pitch was too low or the voice was too aperiodic), but no statistical significant differences were found for any of the acoustical parameters studied. However, the maximum phonation time was significantly longer, and the dynamic range significantly larger, under the Stomafilter occlusion condition. The maximum phonation time showed a relevant improvement in 57% of the patients, while the dynamic range showed a relevant improvement in 35% of the patients. In total, 75% of the patients experience an improvement in one or both of these speech characteristics when using the Stomafilter occlusion. It can be concluded that optimal stoma occlusion by means of a specialized device has a positive influence on two relevant parameters of prosthetic voice production: maximum phonation time and dynamic loudness range. PMID:9840514

  5. Membrane stabilizer

    DOEpatents

    Mingenbach, W.A.

    1988-02-09

    A device is provided for stabilizing a flexible membrane secured within a frame, wherein a plurality of elongated arms are disposed radially from a central hub which penetrates the membrane, said arms imposing alternately against opposite sides of the membrane, thus warping and tensioning the membrane into a condition of improved stability. The membrane may be an opaque or translucent sheet or other material. 10 figs.

  6. Rotating bubble membrane radiator

    DOEpatents

    Webb, Brent J.; Coomes, Edmund P.

    1988-12-06

    A heat radiator useful for expelling waste heat from a power generating system aboard a space vehicle is disclosed. Liquid to be cooled is passed to the interior of a rotating bubble membrane radiator, where it is sprayed into the interior of the bubble. Liquid impacting upon the interior surface of the bubble is cooled and the heat radiated from the outer surface of the membrane. Cooled liquid is collected by the action of centrifical force about the equator of the rotating membrane and returned to the power system. Details regarding a complete space power system employing the radiator are given.

  7. Modified Occlusal Rim Design and Use of Phonetics to Determine Anterior Tooth Position and Vertical Dimension: A Clinical Report.

    PubMed

    Romero, Mario F; DeRosa, Thomas A

    2016-06-01

    Prosthetic rehabilitation of edentulous patients can sometimes pose many clinical challenges for the clinician. The importance of correct vertical and horizontal positioning of the anterior teeth so that the completed denture is esthetically pleasing while being functionally correct has been well documented in the literature. Different techniques have been proposed whereby a conventional occlusal rim is used. The wax-rim thickness of this design can interfere with the neutral zone, making normal phonetics difficult. In this report, a completely edentulous patient received treatment using a modified occlusal rim so that phonetics could be used to determine the anterior tooth position and vertical dimension, following a strict adherence to a clinical protocol. The methodology involved the use of heat-processed resin record bases and a thin segment of baseplate wax that mimics anterior teeth. This approach resulted in a more natural feeling for the patient and provided the clinician the necessary information for the laboratory, which was easily communicated. PMID:27525732

  8. [Ruptured Internal Carotid Artery Aneurysm Coiling in a Patient with Ipsilateral Internal Carotid Artery Occlusion via the Posterior Communicating Artery].

    PubMed

    Ashida, Noriaki; Saitoh, Minoru; Fujita, Atsushi; Kohmura, Eiji

    2016-09-01

    Background:De novo aneurysms after internal carotid artery(ICA)occlusion occur in the contralateral ICA or anterior communicating artery. Hemodynamic changes with increased blood flow to the contralateral carotid circulation were considered the main factor for the formation of these aneurysms. We report a rare case of ruptured ICA aneurysm associated with ipsilateral ICA occlusion treated with coil embolization via the vertebrobasilar and posterior communicating arteries. Case Presentation:An 82-year-old woman presented with sudden-onset disturbance of consciousness at our outpatient clinic and went into cardiopulmonary arrest. Computed tomography(CT)performed after cardiopulmonary resuscitation revealed diffuse subarachnoid hemorrhage. Three-dimensional CT angiography revealed a right ICA aneurysm associated with the ipsilateral ICA occlusion. Considering that the patient showed clinical improvement with the critical care for neurogenic pulmonary edema, the aneurysm was treated with endovascular coil embolization via the posterior communicating artery. With this technique, complete obliteration was attained without perioperative complication. Conclusion:Endovascular coil embolization via the posterior communicating artery was proven effective as a treatment method for ruptured ICA aneurysms with ipsilateral ICA occlusion. Hemodynamic stress due to increased blood flow in the posterior communicating artery may play an important role in the growth and rupture of ICA aneurysms. PMID:27605482

  9. Time management in acute vertebrobasilar occlusion.

    PubMed

    Kamper, Lars; Rybacki, Konrad; Mansour, Michael; Winkler, Sven B; Kempkes, Udo; Haage, Patrick

    2009-03-01

    Acute vertebrobasilar occlusion (VBO) is associated with a high risk of stroke and death. Although local thrombolysis may achieve recanalization and improve outcome, mortality is still between 35% and 75%. However, without recanalization the chance of a good outcome is extremely poor, with mortality rates of 80-90%. Early treatment is a fundamental factor, but detailed studies of the exact time management of the diagnostic and interventional workflow are still lacking. Data on 18 patients were retrospectively evaluated. Time periods between symptom onset, admission to hospital, time of diagnosis, and beginning of intervention were correlated with postinterventional neurological status. The Glasgow Coma Scale and National Institute of Health Stroke Scale (NIHSS) were used to examine patients before and after local thrombolysis. Additionally, multivariate statistics were applied to reveal similarities between patients with neurological improvement. Primary recanalization was achieved in 77% of patients. The overall mortality was 55%. Major complications were intracranial hemorrhage and peripheral embolism. The time period from symptom onset to intervention showed a strong correlation with the postinterventional NIHSS as well as the patient's age, with the best results in a 4-h interval. Multivariate statistics revealed similarities among the patients. Evaluation of time management in acute VBO by multivariate statistics is a helpful tool for definition of similarities in this patient group. Similarly to the door-to-balloon time for acute coronary interventions, the chances for a good outcome depend on a short time interval between symptom onset and intervention. While the only manipulable time period starts with hospital admission, our results emphasize the necessity of efficient intrahospital workflow. PMID:18704570

  10. Detecting and Treating Occlusal Caries Lesions

    PubMed Central

    Stolpe, M.; Meyer-Lueckel, H.; Paris, S.

    2015-01-01

    The health gains and costs resulting from using different caries detection strategies might not only depend on the accuracy of the used method but also the treatment emanating from its use in different populations. We compared combinations of visual-tactile, radiographic, or laser-fluorescence–based detection methods with 1 of 3 treatments (non-, micro-, and invasive treatment) initiated at different cutoffs (treating all or only dentinal lesions) in populations with low or high caries prevalence. A Markov model was constructed to follow an occlusal surface in a permanent molar in an initially 12-y-old male German patient over his lifetime. Prevalence data and transition probabilities were extracted from the literature, while validity parameters of different methods were synthesized or obtained from systematic reviews. Microsimulations were performed to analyze the model, assuming a German health care setting and a mixed public-private payer perspective. Radiographic and fluorescence-based methods led to more overtreatments, especially in populations with low prevalence. For the latter, combining visual-tactile or radiographic detection with microinvasive treatment retained teeth longest (mean 66 y) at lowest costs (329 and 332 Euro, respectively), while combining radiographic or fluorescence-based detections with invasive treatment was the least cost-effective (<60 y, >700 Euro). In populations with high prevalence, combining radiographic detection with microinvasive treatment was most cost-effective (63 y, 528 Euro), while sensitive detection methods combined with invasive treatments were again the least cost-effective (<59 y, >690 Euro). The suitability of detection methods differed significantly between populations, and the cost-effectiveness was greatly influenced by the treatment initiated after lesion detection. The accuracy of a detection method relative to a “gold standard” did not automatically convey into better health or reduced costs. Detection

  11. Leptospirosis and Peripheral Artery Occlusive Disease

    PubMed Central

    Chiu, Chun-Hsiang; Lin, Cheng-Li; Lee, Feng-You; Wang, Ying-Chuan; Kao, Chia-Hung

    2016-01-01

    Abstract Data on the association between peripheral artery occlusive disease (PAOD) and leptospirosis are limited. We conducted a retrospective cohort study for determining whether leptospirosis is one of the possible risk factors for PAOD. Patients diagnosed with leptospirosis by using 2000 to 2010 data from the Taiwan National Health Insurance Research Database. Patients with leptospirosis without a history of PAOD were selected. For each leptospirosis patient, 4 controls without a history of leptospirosis and PAOD were randomly selected and frequency-matched for sex, age, the year of the index date, and comorbidity diseases. The follow-up period was from the time of the initial diagnosis of leptospirosis to the diagnosis date of PAOD, or December 31, 2011. The Cox proportional hazard regression models were used for analyzing the risk of PAOD. During the follow-up period, the cumulative incidence of PAOD was higher among the patients from the leptospirosis cohort than among the nonleptospirosis cohort (log-rank test, P < 0.001). In total, 29 patients with PAOD from the leptospirosis cohort and 81 from the nonleptospirosis cohort were observed with the incidence rates of 2.1 and 1.3 per 1000 person-years, respectively, yielding a crude hazards ratio (HR) of 1.62 (95% confidence interval [CI] = 1.44–1.81) and adjusted HR (aHR) of 1.75 (95% CI = 1.58–1.95). The risk of PAOD was 1.75-fold higher in the patients with leptospirosis than in the general population. PMID:26986166

  12. Time Management in Acute Vertebrobasilar Occlusion

    SciTech Connect

    Kamper, Lars; Mansour, Michael; Winkler, Sven B.; Kempkes, Udo; Haage, Patrick

    2009-03-15

    Acute vertebrobasilar occlusion (VBO) is associated with a high risk of stroke and death. Although local thrombolysis may achieve recanalization and improve outcome, mortality is still between 35% and 75%. However, without recanalization the chance of a good outcome is extremely poor, with mortality rates of 80-90%. Early treatment is a fundamental factor, but detailed studies of the exact time management of the diagnostic and interventional workflow are still lacking. Data on 18 patients were retrospectively evaluated. Time periods between symptom onset, admission to hospital, time of diagnosis, and beginning of intervention were correlated with postinterventional neurological status. The Glasgow Coma Scale and National Institute of Health Stroke Scale (NIHSS) were used to examine patients before and after local thrombolysis. Additionally, multivariate statistics were applied to reveal similarities between patients with neurological improvement. Primary recanalization was achieved in 77% of patients. The overall mortality was 55%. Major complications were intracranial hemorrhage and peripheral embolism. The time period from symptom onset to intervention showed a strong correlation with the postinterventional NIHSS as well as the patient's age, with the best results in a 4-h interval. Multivariate statistics revealed similarities among the patients. Evaluation of time management in acute VBO by multivariate statistics is a helpful tool for definition of similarities in this patient group. Similarly to the door-to-balloon time for acute coronary interventions, the chances for a good outcome depend on a short time interval between symptom onset and intervention. While the only manipulable time period starts with hospital admission, our results emphasize the necessity of efficient intrahospital workflow.

  13. Metamorphopsia Associated with Branch Retinal Vein Occlusion

    PubMed Central

    Manabe, Koichiro; Tsujikawa, Akitaka; Osaka, Rie; Nakano, Yuki; Fujita, Tomoyoshi; Shiragami, Chieko; Hirooka, Kazuyuki; Uji, Akihito; Muraoka, Yuki

    2016-01-01

    Purpose To apply M-CHARTS for quantitative measurements of metamorphopsia in eyes with acute branch retinal vein occlusion (BRVO) and to elucidate the pathomorphology that causes metamorphopsia. Methods This prospective study consisted of 42 consecutive patients (42 eyes) with acute BRVO. Both at baseline and one month after treatment with ranibizumab, metamorphopsia was measured with M-CHARTS, and the retinal morphological changes were examined with optical coherence tomography. Results At baseline, metamorphopsia was detected in the vertical and/or horizontal directions in 29 (69.0%) eyes; the mean vertical and horizontal scores were 0.59 ± 0.57 and 0.52 ± 0.67, respectively. The maximum inner retinal thickness showed no association with the M-CHARTS score, but the M-CHARTS score was correlated with the total foveal thickness (r = 0.43, p = 0.004), the height of serous retinal detachment (r = 0.31, p = 0.047), and the maximum outer retinal thickness (r = 0.36, p = 0.020). One month after treatment, both the inner and outer retinal thickness substantially decreased. However, metamorphopsia persisted in 26 (89.7%) of 29 eyes. The posttreatment M-CHARTS score was not correlated with any posttreatment morphological parameters. However, the posttreatment M-CHARTS score was weakly correlated with the baseline total foveal thickness (r = 0.35. p = 0.024) and closely correlated with the baseline M-CHARTS score (r = 0.78, p < 0.001). Conclusions Metamorphopsia associated with acute BRVO was quantified using M-CHARTS. Initial microstructural changes in the outer retina from acute BRVO may primarily account for the metamorphopsia. PMID:27123642

  14. Sex Differences During Visual Scanning of Occlusion Events in Infants

    PubMed Central

    Wilcox, Teresa; Alexander, Gerianne M.; Wheeler, Lesley; Norvell, Jennifer M.

    2013-01-01

    A growing number of sex differences in infant behavior have been reported over the last 10 years. One task on which sex differences have been observed reliably is the event-mapping task. In this task, infants view an occlusion event involving 1 or 2 objects, the occluder is removed, and then infants see 1 object sitting on the platform. When the occlusion sequence is complex (i.e., involves paths of motion that change direction when occluded), boys are more likely than girls to detect an inconsistency between a 2-object occlusion event and a 1-object display. The current research used eye-tracking technology to investigate the specific cognitive processes that underlie these sex differences. Three experiments were conducted with 2 age groups of infants with mean ages of 9 months and 4 months. Infants saw a ball–box (2-object) or ball–ball (1-object) occlusion event followed by a 1-ball display; visual scanning of the occlusion event and the 1-ball display was recorded. In the older age group, boys were more likely than girls to visually track the objects through occlusion; they were also more likely to detect an inconsistency between the ball–box event and the 1-ball display (i.e., they visually searched for the missing box). In addition, tracking of the objects through occlusion was related to infants' scanning of the 1-ball display. In the younger age group, both boys and girls failed to track the objects through occlusion and to detect an inconsistency between the ball–box event and the 1–ball display. These results suggest that infants' capacity to track objects through occlusion facilitates extraction of the structure of the initial event (i.e., the number of distinct objects involved), that infants can map onto the final display, and that sex differences in this ability emerge between 4 and 9 months. Possible explanations for how the structure of an occlusion event is extracted and mapped onto a subsequent nonocclusion display are considered. PMID

  15. A practical three visit complete denture system.

    PubMed

    Ling, B C

    2000-10-01

    Standard prosthodontic procedures require five visits to construct a set of complete maxillary and mandibular dentures. Various attempts have been made to reduce these procedures to four or three appointments. However, most of these techniques require the use of visible light polymerized resin as the final denture base materials. Visible light-cured resin materials have inferior physical properties and biocompatibility problems as compared with heat cured polymethylmethacrylate. This paper describes a system of complete denture construction which requires three clinical appointments instead of the usual five visits. This system is made possible by using the VLC base/tray material as the preliminary impression material as well as the application of a new biometric wax occlusion rim. It retains the use of polymethylmethacrylate as the denture base material. This system also utilizes all the procedures used in the conventional five appointment system of complete denture construction. PMID:11709981

  16. Use of PTFE Stent Grafts for Hemodialysis-related Central Venous Occlusions: Intermediate-Term Results

    SciTech Connect

    Kundu, Sanjoy Modabber, Milad; You, John M.; Tam, Paul; Nagai, Gordon; Ting, Robert

    2011-10-15

    Purpose: To assess the safety and effectiveness of a polytetrafluoroethylene (PTFE) encapsulated nitinol stents (Bard Peripheral Vascular, Tempe, AZ) for treatment of hemodialysis-related central venous occlusions. Materials and Methods: Study design was a single-center nonrandomized retrospective cohort of patients from May 2004 to August 2009 for a total of 64 months. There were 14 patients (mean age 60 years, range 50-83 years; 13 male, 1 female). All patients had autogenous fistulas. All 14 patients had central venous occlusions and presented with clinical symptoms of the following: extremity swelling (14%, 2 of 14), extremity and face swelling (72%, 10 of 14), and face swelling/edema (14%, 2 of 14). There was evidence of access dysfunction with decreased access flow in 36% (5 of 14) patients. There were prior interventions or previous line placement at the site of the central venous lesion in all 14 patients. Results were assessed by recurrence of clinical symptoms and function of the access circuit (National Kidney Foundation recommended criteria). Results: Sixteen consecutive straight stent grafts were implanted in 14 patients. Average treated lesion length was 5.0 cm (range, 0.9-7 cm). All 14 patients had complete central venous occlusion (100% stenosis). The central venous occlusions were located as follows: right subclavian and brachiocephalic vein (21%, 3 of 14), right brachiocephalic vein (36%, 5 of 14), left brachiocephalic vein (36%, 5 of 14), and bilateral brachiocephalic vein (7%, 1 of 14). A total of 16 PTFE stent grafts were placed. Ten- or 12-mm-diameter PTFE stent grafts were placed. The average stent length was 6.1 cm (range, 4-8 cm). Technical (deployment), anatomic (<30% residual stenosis), clinical (resolution of symptoms), and hemodynamic (resolution of access dysfunction) success were 100%. At 3, 6, and 9 months, primary patency of the treated area and access circuit were 100% (14 of 14). Conclusions: This PTFE encapsulated stent graft

  17. Occlusion of retinal capillaries caused by glial cell proliferation in chronic ocular inflammation.

    PubMed

    Bianchi, E; Ripandelli, G; Feher, J; Plateroti, A M; Plateroti, R; Kovacs, I; Plateroti, P; Taurone, S; Artico, M

    2015-01-01

    The inner blood-retinal barrier is a gliovascular unit in which glial cells surround capillary endothelial cells and regulate retinal capillaries by paracrine interactions. During chronic ocular inflammation, microvascular complications can give rise to vascular proliferative lesions, which compromise visual acuity. This pathologic remodelling caused by proliferating Müller cells determines occlusion of retinal capillaries. The aim of the present study was to identify qualitative and quantitative alterations in the retinal capillaries in patients with post-traumatic chronic ocular inflammation or post-thrombotic vascular glaucoma. Moreover, we investigated the potential role of vascular endothelial growth factor (VEGF) and pro-inflammatory cytokines in retinal inflammation. Our electron microscopy findings demonstrated that during chronic ocular inflammation, thickening of the basement membrane, loss of pericytes and endothelial cells and proliferation of Müller cells occur with irreversible occlusion of retinal capillaries. Angiogenesis takes place as part of a regenerative reaction that results in fibrosis. We believe that VEGF and pro-inflammatory cytokines may be potential therapeutic targets in the treatment of this disease although further studies are required to confirm these findings. PMID:25792393

  18. Coronary occlusive disease and late graft failure after cardiac transplantation

    PubMed Central

    Mullins, P A; Cary, N R; Sharples, L; Scott, J; Aravot, D; Large, S R; Wallwork, J; Schofield, P M

    1992-01-01

    Objective—Coronary occlusive disease is the main cause of late mortality after cardiac transplantation. It has both similarities and differences compared with conventional atherosclerotic coronary disease. The pathophysiology of late graft failure from coronary occlusive disease is unclear at present. We reviewed the experience of this disorder in our cardiac transplant programme. Design—A retrospective analysis of angiographic and pathological data. Setting—A regional cardiothoracic centre and transplant unit. Patients—Of a population of 383 orthotopic cardiac transplant recipients operated upon between January 1979 and June 1990, 447 coronary angiograms were available for review in 193 patients. Thirteen of a possible 18 results of post mortem examinations from patients dying from coronary occlusive disease were available. Main outcome measure—Coronary occlusive disease was defined as any evidence of disease on coronary angiography. Post mortem examinations were performed with standard techniques. Results The angiographic prevalence of coronary occlusive disease was 3% (1/32 patients) and 40% (19/47 patients) at one and five years respectively. Twenty six grafts failed due to coronary occlusive disease compared with 132 graft failures from all causes during this period. Acute thrombosis was present in a large vessel in seven of 13 fatal cases undergoing necropsy (54%). Noticeable large vessel involvement with disease in smaller distal vessels was present in four patients (31%). The remaining two patients (15%) had small vessel disease alone. Twelve of the 13 patients had significant cardiomegaly (cardiac weight ≥400 g) with a mean weight of 510 (range 370-740) g. Conclusion—Coronary occlusive disease is the main late complication after cardiac transplantation. A combination of coronary thrombosis, ischaemia from stenoses of large and small coronary vessels, and cardiomegaly contribute to the graft failure of these patients. PMID:1389755

  19. Central retinal vein occlusion: modifying current treatment protocols.

    PubMed

    Ashraf, M; Souka, A A R; Singh, R P

    2016-04-01

    Central retinal vein occlusion (CRVO) is a common retinal vascular disorder that can result in severe visual acuity loss. The randomized control study, CRUISE, helped establish anti-VEGFs as the standard of care in cases with CRVO. The extension studies for CRUISE; HORIZON and RETAIN showed that not all visual gains are maintained beyond the first year. In addition, patients showed different behavior patterns; with some patients showing complete response with few recurrences, whereas others showed partial or even no response with multiple recurrences. Long-term follow-up demonstrated that patients responding poorly to anti-VEGFs tended to do so early in the course of treatment. It also demonstrated the effectiveness of a pro re nata (PRN) protocol for improving vision and maintaining these gains over long-term follow-ups. The SHORE study further illustrated this point by demonstrating that there were minimal differences in visual outcomes between patients receiving monthly injections and patients being treated PRN. In this review we analyzed the data from the major randomized clinical trials (RCT) that looked at anti-VEGFs as the primary treatment modality in patients with CRVO (CRUISE and the extension studies HORIZON and RETAIN for ranibizumab as well as GALILEO and COPERNICUS for aflibercept). In addition, we looked at SCORE and GENEVA to help determine whether there is a place for steroids as a first line therapy in current treatment practice. We then explored alternative treatment regimens such as laser therapy and switching between anti-VEGF agents and/or steroids for non or partially responding patients. Finally, we propose a simplified modified treatment algorithm for patients with CRVO for better long-term outcomes in all types of responders. PMID:26869163

  20. Membrane tension and membrane fusion.

    PubMed

    Kozlov, Michael M; Chernomordik, Leonid V

    2015-08-01

    Diverse cell biological processes that involve shaping and remodeling of cell membranes are regulated by membrane lateral tension. Here we focus on the role of tension in driving membrane fusion. We discuss the physics of membrane tension, forces that can generate the tension in plasma membrane of a cell, and the hypothesis that tension powers expansion of membrane fusion pores in late stages of cell-to-cell and exocytotic fusion. We propose that fusion pore expansion can require unusually large membrane tensions or, alternatively, low line tensions of the pore resulting from accumulation in the pore rim of membrane-bending proteins. Increase of the inter-membrane distance facilitates the reaction. PMID:26282924

  1. Membrane tethering

    PubMed Central

    Chia, Pei Zhi Cheryl

    2014-01-01

    Membrane trafficking depends on transport vesicles and carriers docking and fusing with the target organelle for the delivery of cargo. Membrane tethers and small guanosine triphosphatases (GTPases) mediate the docking of transport vesicles/carriers to enhance the efficiency of the subsequent SNARE (soluble N-ethylmaleimide-sensitive factor attachment protein receptor)-mediated fusion event with the target membrane bilayer. Different classes of membrane tethers and their specific intracellular location throughout the endomembrane system are now well defined. Recent biochemical and structural studies have led to a deeper understanding of the mechanism by which membrane tethers mediate docking of membrane carriers as well as an appreciation of the role of tethers in coordinating the correct SNARE complex and in regulating the organization of membrane compartments. This review will summarize the properties and roles of membrane tethers of both secretory and endocytic systems. PMID:25343031

  2. Reticulation of low density shape memory polymer foam with an in vivo demonstration of vascular occlusion

    SciTech Connect

    Rodriguez, Jennifer N.; Miller, Matthew W.; Boyle, Anthony; Horn, John; Yang, Cheng-Kang; Wilson, Thomas S.; Ortega, Jason M.; Small, Ward; Nash, Landon; Skoog, Hunter; Maitland, Duncan J.

    2014-08-11

    Recently, predominantly closed-cell low density shape memory polymer (SMP) foam was reported to be an effective aneurysm filling device in a porcine model (Rodriguez et al., Journal of Biomedical Materials Research Part A 2013: (http://dx.doi.org/10.1002/jbm.a.34782)). Because healing involves blood clotting and cell migration throughout the foam volume, a more open-cell structure may further enhance the healing response. This research sought to develop a non-destructive reticulation process for this SMP foam to disrupt the membranes between pore cells. Non-destructive mechanical reticulation was achieved using a gravity-driven floating nitinol pin array coupled with vibratory agitation of the foam and supplemental chemical etching. Lastly, reticulation resulted in a reduced elastic modulus and increased permeability, but did not impede the shape memory behavior. Reticulated foams were capable of achieving rapid vascular occlusion in an in vivo porcine model.

  3. Reticulation of low density shape memory polymer foam with an in vivo demonstration of vascular occlusion

    DOE PAGESBeta

    Rodriguez, Jennifer N.; Miller, Matthew W.; Boyle, Anthony; Horn, John; Yang, Cheng-Kang; Wilson, Thomas S.; Ortega, Jason M.; Small, Ward; Nash, Landon; Skoog, Hunter; et al

    2014-08-11

    Recently, predominantly closed-cell low density shape memory polymer (SMP) foam was reported to be an effective aneurysm filling device in a porcine model (Rodriguez et al., Journal of Biomedical Materials Research Part A 2013: (http://dx.doi.org/10.1002/jbm.a.34782)). Because healing involves blood clotting and cell migration throughout the foam volume, a more open-cell structure may further enhance the healing response. This research sought to develop a non-destructive reticulation process for this SMP foam to disrupt the membranes between pore cells. Non-destructive mechanical reticulation was achieved using a gravity-driven floating nitinol pin array coupled with vibratory agitation of the foam and supplemental chemical etching.more » Lastly, reticulation resulted in a reduced elastic modulus and increased permeability, but did not impede the shape memory behavior. Reticulated foams were capable of achieving rapid vascular occlusion in an in vivo porcine model.« less

  4. Reticulation of low density shape memory polymer foam with an in vivo demonstration of vascular occlusion

    PubMed Central

    Rodriguez, Jennifer N.; Miller, Matthew W.; Boyle, Anthony; Horn, John; Yang, Cheng-Kang; Wilson, Thomas S.; Ortega, Jason M.; Small, Ward; Nash, Landon; Skoog, Hunter; Maitland, Duncan J.

    2014-01-01

    Predominantly closed-cell low density shape memory polymer (SMP) foam was recently reported to be an effective aneurysm filling device in a porcine model (Rodriguez et al., Journal of Biomedical Materials Research Part A 2013: (http://dx.doi.org/10.1002/jbm.a.34782)). Because healing involves blood clotting and cell migration throughout the foam volume, a more open-cell structure may further enhance the healing response. This research sought to develop a non-destructive reticulation process for this SMP foam to disrupt the membranes between pore cells. Non-destructive mechanical reticulation was achieved using a gravity-driven floating nitinol pin array coupled with vibratory agitation of the foam and supplemental chemical etching. Reticulation resulted in a reduced elastic modulus and increased permeability, but did not impede shape memory behavior. Reticulated foams were capable of achieving rapid vascular occlusion in an in vivo porcine model. PMID:25222869

  5. Micro-PIV quantification of capillary blood flow redistribution caused by laser-assisted vascular occlusion

    NASA Astrophysics Data System (ADS)

    Kurochkin, Maxim A.; Stiukhina, Elena S.; Fedosov, Ivan V.; Postnov, Dmitry E.; Tuchin, Valery V.

    2016-04-01

    We propose μPIV-based technique for quantitative assessment of blood flow redistribution in microcirculatory networks. Our approach is based on per-segment averaging of measured quantities so we can avoid most of problems that are typical for point-wise measurements. The key point of our technique is the digital processing algorithms of recorded data that include: capillary network axial line construction; interrogation regions centering; blood flow velocity local estimate using PIV approach; blood flow velocity calculation by means of averaging over entire vessel segment; the calculation of blood volume flow rate map. We illustrate the application of developed technique with in vivo measurements and blood flow velocity map reconstruction for chorioallantoic membrane (CAM) of chicken embryo, in which the local vascular occlusion was produced using continuous wave laser light irradiation..

  6. Reticulation of low density shape memory polymer foam with an in vivo demonstration of vascular occlusion.

    PubMed

    Rodriguez, Jennifer N; Miller, Matthew W; Boyle, Anthony; Horn, John; Yang, Cheng-Kang; Wilson, Thomas S; Ortega, Jason M; Small, Ward; Nash, Landon; Skoog, Hunter; Maitland, Duncan J

    2014-12-01

    Predominantly closed-cell low density shape memory polymer (SMP) foam was recently reported to be an effective aneurysm filling device in a porcine model (Rodriguez et al., Journal of Biomedical Materials Research Part A 2013: (http://dx.doi.org/10.1002/jbm.a.34782)). Because healing involves blood clotting and cell migration throughout the foam volume, a more open-cell structure may further enhance the healing response. This research sought to develop a non-destructive reticulation process for this SMP foam to disrupt the membranes between pore cells. Non-destructive mechanical reticulation was achieved using a gravity-driven floating nitinol pin array coupled with vibratory agitation of the foam and supplemental chemical etching. Reticulation resulted in a reduced elastic modulus and increased permeability, but did not impede the shape memory behavior. Reticulated foams were capable of achieving rapid vascular occlusion in an in vivo porcine model. PMID:25222869

  7. Optic Nerve Sheath Melanoma Presenting as a Central Retinal Vein Occlusion.

    PubMed

    Barash, Alexander; Sibony, Patrick A; Stippa, Nigel A; Boyle, Nariman S; Davis, James E

    2016-03-01

    A 64-year-old woman, with a history of diabetes and melanoma, developed a central retinal vein occlusion (CRVO) in her left eye. On exam, she had severe disc edema with retinal nerve fiber layer thickening, and anterior deformation of the peripapillary retinal pigment epithelium (RPE)/Bruch membrane layer (ppRPE/BM) toward the vitreous on spectral domain optical coherence tomography (SD-OCT) suggesting an optic nerve sheath (ONS) meningioma. Magnetic resonance imaging findings and ONS biopsy later confirmed a metastatic melanoma. This case demonstrates that the shape of the RPE/BM on SD-OCT may aid in the decision to consider imaging in patients with isolated CRVO. PMID:26535468

  8. Imaging natural occlusal caries lesions with optical coherence tomography

    NASA Astrophysics Data System (ADS)

    Douglas, Shane M.; Fried, Daniel; Darling, Cynthia L.

    2010-02-01

    Several studies have demonstrated that polarization-sensitive optical coherence tomography (PS-OCT) can be used to nondestructively measure the severity of demineralization in the important occlusal surfaces. The purpose of this study was to assess the potential of PS-OCT and OCT methods for the measurement of the depth of natural occlusal carious lesions. Teeth were screened for potential occlusal lesions using near infrared imaging (NIR). A PS-OCT system operating at 1310-nm was used to acquire polarization resolved images of the area of interest on the occlusal surface. The teeth were serial sectioned to 200 μm thickness and examined with polarized light microscopy (PLM) and Transverse Microradiography (TMR) for comparison. The lesion depth measured nondestructively with PS-OCT was compared to the lesion depth measured with PLM and TMR to assess the performance of these methods and determine if polarization sensitivity is required. The lesion depth measured using OCT correlated well with the lesion depths measured with TMR and PLM. Although polarization sensitivity provided better contrast it was not necessary to have polarization sensitivity to identify deep occlusal lesions.

  9. Occlusive versus nonocclusive calcipotriol ointment treatment for palmoplantar psoriasis.

    PubMed

    Duweb, G A; Abuzariba, O; Rahim, M; al-Taweel, M; al-Alem, S; Abdulla, S A

    2001-01-01

    Thirty-nine patients with a clinical diagnosis of palmoplantar psoriasis [23 (58%) males and 16 (42%) females] were included in this study with the aim of evaluating the efficacy of occlusive calcipotriol 50 micrograms/mg ointment vs. nonocclusive therapy. Patients were randomized to either twice-weekly overnight calcipotriol ointment under occlusion or twice-daily topical nonocclusive application of the same ointment for 6 weeks. The effect of treatment was assessed on the basis of a psoriasis signs score for erythema, thickness and scaliness, which was graded from 0 (absent) to 4 (most severe) at the first visit, after 2 weeks and at the end of treatment. Analysis of our results showed that twice-weekly occlusive calcipotriol ointment was as effective as the twice-daily application. The mean total score at baseline was 6 for the occlusive group and 6.1 for the nonocclusive group. The score decreased to 1.5 in both groups at the end of treatment. No significant adverse effects were reported by patients or investigators. We conclude that occlusive calcipotriol ointment is effective in the treatment of palmoplantar psoriasis and may produce even better results with more frequent use, such as application on alternate days. PMID:11447774

  10. Molecular studies of the structural ecology of natural occlusal caries.

    PubMed

    Dige, Irene; Grønkjær, Lene; Nyvad, Bente

    2014-01-01

    Microbiological studies of occlusal dental biofilms have hitherto been hampered by inaccessibility to the sampling site and demolition of the original biofilm architecture. This study shows for the first time the spatial distribution of bacterial taxa in vivo at various stages of occlusal caries, applying a molecular methodology involving preparation of embedded hard dental tissue slices for fluorescence in situ hybridization (FISH) and confocal microscopy. Eleven freshly extracted teeth were classified according to their occlusal caries status. The teeth were fixed, embedded, sectioned and decalcified before FISH was performed using oligonucleotide probes for selected abundant species/genera associated with occlusal caries including Streptococcus, Actinomyces, Veillonella, Fusobacterium, Lactobacillus and Bifidobacterium. The sites showed distinct differences in the bacterial composition between different ecological niches in occlusal caries. Biofilm observed along the entrance of fissures showed an inner layer of microorganisms organized in palisades often identified as Actinomyces, covered by a more loosely structured bacterial layer consisting of diverse genera, similar to supragingival biofilm. Biofilm within the fissure proper seemed less metabolically active, as judged by low fluorescence signal intensity and presence of material of non-bacterial origin. Bacterial invasion (often Lactobacillus and Bifidobacterium spp.) into the dentinal tubules was seen only at advanced stages of caries with manifest cavity formation. It is concluded that the molecular methodology represents a valuable supplement to previous methods for the study of microbial ecology in caries by allowing analysis of the structural composition of the undisturbed biofilm in caries lesions in vivo. PMID:24852305

  11. The muscle engram: the reflex that limits conventional occlusal treatment.

    PubMed

    Lerman, Martin D

    2011-10-01

    The engram (the masticatory "muscle memory") is shown to be a conditionable reflex whose muscle conditioning lasts less than two minutes, far shorter than previously thought. This reflex, reinforced and stored in the masticatory muscles at every swallow, adjusts masticatory muscle activity to guide the lower arch unerringly into its ICP. These muscle adjustments compensate for the continually changing intemal and external factors that affect the mandible's entry into the ICP. A simple quick experiment described in this article isolates the engram, enabling the reader to see its action clearly for the first time. It is urged that every reader perform this experiment. This experiment shows how the engram, by hiding the masticatory muscles' reaction (the hit-and-slide), limits the success of the therapist in achieving occlusion-muscle compatibility. This finding has major clinical implications. It means that, as regards the muscle aspect of treating occlusion, the dentist treating occlusion conventionally is working blind, a situation the neuromuscular school of occlusal thought seeks to correct. The controversy over occlusion continues. PMID:22128670

  12. Load-bearing properties of minimal-invasive monolithic lithium disilicate and zirconia occlusal onlays: finite element and theoretical analyses

    PubMed Central

    Ma, Li; Guess, Petra C.; Zhang, Yu

    2013-01-01

    Objectives The aim of this study was to test the hypothesis that monolithic lithium disilicate glass-ceramic occlusal onlay can exhibit a load-bearing capacity that approaches monolithic zirconia, due to a smaller elastic modulus mismatch between the lithium disilicate and its supporting tooth structure relative to zirconia. Methods Ceramic occlusal onlays of various thicknesses cemented to either enamel or dentin were considered. Occlusal load was applied through an enamel-like deformable indenter or a control rigid indenter. Flexural tensile stress at the ceramic intaglio (cementation) surface—a cause for bulk fracture of occlusal onlays—was rigorously analyzed using finite element analysis and classical plate-on-foundation theory. Results When bonded to enamel (supported by dentin), the load-bearing capacity of lithium disilicate can approach 75% of that of zirconia, despite the flexural strength of lithium disilicate (400 MPa) being merely 40% of zirconia (1000 MPa). When bonded to dentin (with the enamel completely removed), the load-bearing capacity of lithium disilicate is about 57% of zirconia, still significantly higher than the anticipated value based on its strength. Both ceramics show slightly higher load-bearing capacity when loaded with a deformable indenter (enamel, glass-ceramic, or porcelain) rather than a rigid indenter. Significance When supported by enamel, the load-bearing property of minimally invasive lithium disilicate occlusal onlays (0.6 to 1.4 mm thick) can exceed 70% of that of zircona. Additionally, a relatively weak dependence of fracture load on restoration thickness indicates that a 1.2 mm thin lithium disilicate onlay can be as fracture resistant as its 1.6 mm counterpart. PMID:23683531

  13. Posterior Teeth Occlusion Associated with Cognitive Function in Nursing Home Older Residents: A Cross-Sectional Observational Study.

    PubMed

    Takeuchi, Kenji; Izumi, Maya; Furuta, Michiko; Takeshita, Toru; Shibata, Yukie; Kageyama, Shinya; Ganaha, Seijun; Yamashita, Yoshihisa

    2015-01-01

    Early detection and subsequent reduction of modifiable risk factors for cognitive decline is important for extending healthy life expectancy in the currently aging society. Although a recent increase in studies on the state or number of the teeth and cognitive function, few studies have focused on the association between posterior teeth occlusion necessary to maintain chewing function and cognitive function among older adults. This study examined the association between posterior teeth occlusion and cognitive function in nursing home older residents. In this cross-sectional study, 279 residents aged ≥60 years from eight nursing homes in Aso City, Japan participated in cognitive function and dental status assessments and completed a comprehensive questionnaire survey in 2014. Cognitive function was measured using a Mini-Mental State Examination (MMSE). Posterior teeth occlusion was assessed using a total number of functional tooth units (total-FTUs), depending on the number and location of the remaining natural and artificial teeth on implant-supported, fixed, and removable prostheses. Linear regression models were used to assess univariate and multivariate associations between total-FTUs and MMSE scores. Models were sequentially adjusted for demographic characteristics, number of natural teeth, socioeconomic status, health behaviors, comorbidities, physical function, and nutritional status. Among the 200 residents included in our analysis, mean MMSE scores and total-FTUs were 11.0 ± 8.6 and 9.3 ± 4.6, respectively. Higher total-FTUs were significantly associated with higher MMSE scores after adjustment for demographics and teeth number (B = 0.48, 95% confidence interval [CI] = 0.22-0.74). The association remained significant even after adjustment for all covariates (B = 0.25, 95% CI = 0.01-0.49). The current findings demonstrated that loss of posterior teeth occlusion was independently associated with cognitive decline in nursing home older residents in Japan

  14. Influence of blood flow occlusion on the development of peripheral and central fatigue during small muscle mass handgrip exercise.

    PubMed

    Broxterman, R M; Craig, J C; Smith, J R; Wilcox, S L; Jia, C; Warren, S; Barstow, T J

    2015-09-01

    Critical power represents an important threshold for neuromuscular fatigue development and may, therefore, dictate intensities for which exercise tolerance is determined by the magnitude of fatigue accrued. Peripheral fatigue appears to be constant across O2 delivery conditions for large muscle mass exercise, but this consistency is equivocal for smaller muscle mass exercise. We sought to determine the influence of blood flow occlusion during handgrip exercise on neuromuscular fatigue development and to examine the relationship between neuromuscular fatigue development and W '. Blood flow occlusion influenced the development of both peripheral and central fatigue, thus providing further evidence that the magnitude of peripheral fatigue is not constant across O2 delivery conditions for small muscle mass exercise. W ' appears to be related to the magnitude of fatigue accrued during exercise, which may explain the reported consistency of intramuscular metabolic perturbations and work performed for severe-intensity exercise. The influence of the muscle metabolic milieu on peripheral and central fatigue is currently unclear. Moreover, the relationships between peripheral and central fatigue and the curvature constant (W ') have not been investigated. Six men (age: 25 ± 4 years, body mass: 82 ± 10 kg, height: 179 ± 4 cm) completed four constant power handgrip tests to exhaustion under conditions of control exercise (Con), blood flow occlusion exercise (Occ), Con with 5 min post-exercise blood flow occlusion (Con + Occ), and Occ with 5 min post-exercise blood flow occlusion (Occ + Occ). Neuromuscular fatigue measurements and W ' were obtained for each subject. Each trial resulted in significant peripheral and central fatigue. Significantly greater peripheral (79.7 ± 5.1% vs. 22.7 ± 6.0%) and central (42.6 ± 3.9% vs. 4.9 ± 2.0%) fatigue occurred for Occ than for Con. In addition, significantly greater peripheral (83.0 ± 4.2% vs. 69.0 ± 6.2%) and central

  15. A patient with bilateral persistent pupillary membrane: a conservative approach.

    PubMed

    Kurt, Emin

    2009-01-01

    The author describes the case of a girl with bilateral persistent pupillary membranes and good visual acuity. An otherwise healthy 10-year-old girl presented with persistent pupillary membranes in both eyes since childhood. The patient had ametropic amblyopia, which was treated with spectacles and part-time occlusion therapy, with the patient responding conventionally. After therapy, her best-corrected visual acuity was 20/25 in both eyes. She had stereopsis of 50 seconds of arc, orthophoria, and normal extraocular movements. The remainder of the examination was normal. Patients with bilateral persistent pupillary membranes may not require surgery if there is adequate opening. The author suggests a trial of refractive correction and occlusion therapy before deciding on surgical and laser intervention, even if it seems an absolute requirement. PMID:19791728

  16. Effect of occlusion, directionality and age on horizontal localization

    NASA Astrophysics Data System (ADS)

    Alworth, Lynzee Nicole

    Localization acuity of a given listener is dependent upon the ability discriminate between interaural time and level disparities. Interaural time differences are encoded by low frequency information whereas interaural level differences are encoded by high frequency information. Much research has examined effects of hearing aid microphone technologies and occlusion separately and prior studies have not evaluated age as a factor in localization acuity. Open-fit hearing instruments provide new earmold technologies and varying microphone capabilities; however, these instruments have yet to be evaluated with regard to horizontal localization acuity. Thus, the purpose of this study is to examine the effects of microphone configuration, type of dome in open-fit hearing instruments, and age on the horizontal localization ability of a given listener. Thirty adults participated in this study and were grouped based upon hearing sensitivity and age (young normal hearing, >50 years normal hearing, >50 hearing impaired). Each normal hearing participant completed one localization experiment (unaided/unamplified) where they listened to the stimulus "Baseball" and selected the point of origin. Hearing impaired listeners were fit with the same two receiver-in-the-ear hearing aids and same dome types, thus controlling for microphone technologies, type of dome, and fitting between trials. Hearing impaired listeners completed a total of 7 localization experiments (unaided/unamplified; open dome: omnidirectional, adaptive directional, fixed directional; micromold: omnidirectional, adaptive directional, fixed directional). Overall, results of this study indicate that age significantly affects horizontal localization ability as younger adult listeners with normal hearing made significantly fewer localization errors than older adult listeners with normal hearing. Also, results revealed a significant difference in performance between dome type; however, upon further examination was not

  17. Bleb Nucleation through Membrane Peeling

    NASA Astrophysics Data System (ADS)

    Alert, Ricard; Casademunt, Jaume

    2016-02-01

    We study the nucleation of blebs, i.e., protrusions arising from a local detachment of the membrane from the cortex of a cell. Based on a simple model of elastic linkers with force-dependent kinetics, we show that bleb nucleation is governed by membrane peeling. By this mechanism, the growth or shrinkage of a detached membrane patch is completely determined by the linker kinetics, regardless of the energetic cost of the detachment. We predict the critical nucleation radius for membrane peeling and the corresponding effective energy barrier. These may be typically smaller than those predicted by classical nucleation theory, implying a much faster nucleation. We also perform simulations of a continuum stochastic model of membrane-cortex adhesion to obtain the statistics of bleb nucleation times as a function of the stress on the membrane. The determinant role of membrane peeling changes our understanding of bleb nucleation and opens new directions in the study of blebs.

  18. Structures of membrane proteins

    PubMed Central

    Vinothkumar, Kutti R.; Henderson, Richard

    2010-01-01

    In reviewing the structures of membrane proteins determined up to the end of 2009, we present in words and pictures the most informative examples from each family. We group the structures together according to their function and architecture to provide an overview of the major principles and variations on the most common themes. The first structures, determined 20 years ago, were those of naturally abundant proteins with limited conformational variability, and each membrane protein structure determined was a major landmark. With the advent of complete genome sequences and efficient expression systems, there has been an explosion in the rate of membrane protein structure determination, with many classes represented. New structures are published every month and more than 150 unique membrane protein structures have been determined. This review analyses the reasons for this success, discusses the challenges that still lie ahead, and presents a concise summary of the key achievements with illustrated examples selected from each class. PMID:20667175

  19. Ambient Occlusion Effects for Combined Volumes and Tubular Geometry

    PubMed Central

    Schott, Mathias; Martin, Tobias; Grosset, A.V. Pascal; Smith, Sean T.; Hansen, Charles D.

    2013-01-01

    This paper details a method for interactive direct volume rendering that computes ambient occlusion effects for visualizations that combine both volumetric and geometric primitives, specifically tube-shaped geometric objects representing streamlines, magnetic field lines or DTI fiber tracts. The algorithm extends the recently presented the directional occlusion shading model to allow the rendering of those geometric shapes in combination with a context providing 3D volume, considering mutual occlusion between structures represented by a volume or geometry. Stream tube geometries are computed using an effective spline-based interpolation and approximation scheme that avoids self-intersection and maintains coherent orientation of the stream tube segments to avoid surface deforming twists. Furthermore, strategies to reduce the geometric and specular aliasing of the stream tubes are discussed. PMID:23559506

  20. Transcatheter patch occlusion of experimental atrial septal defects.

    PubMed

    Sideris, Eleftherios B; Sideris, Chrysoula E; Stamatelopoulos, Stamatis F; Moulopoulos, Spyridon D

    2002-11-01

    The effectiveness and safety of transcatheter patch atrial septal defect (ASD) occlusion were studied in 20 piglets. Experimental atrial septal defects were created by foramen ovale dilation. ASDs were corrected by polyurethane patches of two types (flat and sleeve). Specially made balloon catheters supported the patches for periods varying from 1 to 6 days; after this period, the supporting catheters were withdrawn and the patches were released. All transcatheter patches were safely embedded in the atrial septum 48 hr or more after implantation. All defects were fully occluded. One patch became infected. The transcatheter patch experimental ASD occlusion method was found effective and safe, potentially applicable in the occlusion of human ASDs. PMID:12410521

  1. Imaging of occlusive thrombi in acute ischemic stroke

    PubMed Central

    Gasparian, GG; Sanossian, N; Shiroishi, MS; Liebeskind, DS

    2015-01-01

    Thrombi, or clots, often occlude proximal segments of the cerebral arterial circulation in acute ischemic stroke. Thromboembolic occlusion or thrombi superimposed on atherosclerotic plaque are the principal focus of acute stroke therapies such as thrombolysis or thrombectomy. We review the imaging characteristics of thrombi on multimodal CT and MRI, angiography and ultrasonography, summarizing recent studies that facilitate therapeutic decision-making from these noninvasive studies. Information about the location, size and imaging characteristics can be ascertained using these techniques. Imaging findings in relation to occlusive thrombus have been correlated with clot pathology, response to therapeutic interventions, and clinical outcome. Diagnostic evaluation of occlusive thrombi on noninvasive studies now constitutes an integral component of acute stroke management. PMID:25545291

  2. Catalytic nanoporous membranes

    DOEpatents

    Pellin, Michael J; Hryn, John N; Elam, Jeffrey W

    2013-08-27

    A nanoporous catalytic membrane which displays several unique features Including pores which can go through the entire thickness of the membrane. The membrane has a higher catalytic and product selectivity than conventional catalysts. Anodic aluminum oxide (AAO) membranes serve as the catalyst substrate. This substrate is then subjected to Atomic Layer Deposition (ALD), which allows the controlled narrowing of the pores from 40 nm to 10 nm in the substrate by deposition of a preparatory material. Subsequent deposition of a catalytic layer on the inner surfaces of the pores reduces pore sizes to less than 10 nm and allows for a higher degree of reaction selectivity. The small pore sizes allow control over which molecules enter the pores, and the flow-through feature can allow for partial oxidation of reactant species as opposed to complete oxidation. A nanoporous separation membrane, produced by ALD is also provided for use in gaseous and liquid separations. The membrane has a high flow rate of material with 100% selectivity. Also provided is a method for producing a catalytic membrane having flow-through pores and discreet catalytic clusters adhering to the inside surfaces of the pores.

  3. Endovascular Treatment of Veno-Occlusive Behcet's Disease

    SciTech Connect

    Tekbas, Guven; Oguzkurt, Levent Gur, Serkan; Onder, Hakan; Andic, Cagatay

    2012-08-15

    Purpose: To retrospectively evaluate the outcome of endovascular treatments for patients with chronic veno-occlusive disease in different vascular beds secondary to Behcet's disease (BD). There are few case reports on the subject, and this is the largest study to date. Materials and Methods: From January 2001 through October 2009, chronic venous occlusions were treated in 10 patients (all male [age range 18-76 years]) with BD using percutaneous transluminal angioplasty and/or stent placement. All patients were symptomatic and had chronic iliofemoral deep venous thrombosis (DVT; n = 5), central venous occlusion (n = 3), or Budd-Chiari syndrome (BCS; n = 2). All patients met criteria of the International Study Group on Behcet's Disease. Results: Two of five patients with DVT had unsuccessful recanalization attempts. Three patients had successful recanalization with stent placement. All three veins were occluded within 1 month with unsuccessful reinterventions. Three patients with chronic central venous occlusion had successful recanalization with percutaneous transluminal angioplasty (n = 1) and stent placement (n = 2). Two patients had reocclusion with successful reintervention. Two BCS patients had successful treatment with stent placements. Overall technical success was 69%, and no procedural complications were encountered. None of the patients with chronic DVT had patent veins; however, all patients with central venous occlusion or BCS had patent veins on color Doppler ultrasonography at follow-up ranging from 3 to 48 months after intervention. Conclusion: Endovenous treatment for chronic iliofemoral DVT due to BD had a poor outcome. However, long-term outcome after endovenous treatment for upper-extremity central venous occlusion and BCS syndrome was good.

  4. [Backshifting of lower canines in occlusion regulation].

    PubMed

    Michałowska-Sarosiek, A; Wedrychowska-Szulc, B; Doniec-Zawidzka, I

    1990-08-01

    In 17 patients the lower canines were shifted back during treatment of prognathic malocclusion and cross-bites. Stable devices with retraction loops, rubber or spring traction were used. The duration of active treatment was about 3 months, on average. During the treatment gaps after the removed premolars were closed completely, although this is nearly impossible when removable devices are applied. PMID:2104380

  5. Mechanisms of Biliary Plastic Stent Occlusion and Efforts at Prevention

    PubMed Central

    Kwon, Chang-Il; Lehman, Glen A.

    2016-01-01

    Biliary stenting via endoscopic retrograde cholangiopancreatography has greatly improved the quality of patient care over the last 30 years. Plastic stent occlusion limits the life span of such stents. Attempts to improve plastic stent patency duration have mostly failed. Metal stents (self-expandable metal stents [SEMSs]) have therefore replaced plastic stents, especially for malignant biliary strictures. SEMS are at least 10 times more expensive than plastic stents. In this focused review, we will discuss basic mechanisms of plastic stent occlusion, along with a systematic summary of previous efforts and related studies to improve stent patency and potential new techniques to overcome existing limitations. PMID:27000422

  6. From function to esthetics: anterior or occlusal compromises to esthetics.

    PubMed

    Guichet, D L; Guichet, N F

    1993-01-01

    Increased patient expectations together with improved diagnostic, material, and surgical advances have expanded the boundaries of esthetic dentistry. To optimize functional and esthetic success, existing techniques are being enhanced through careful patient selection and management of the occlusion. During the period from 1991 to 1992, several areas relating anterior or occlusal compromises to esthetics have been identified. These include: dental and skeletal malocclusion, periodontal esthetic defects, restorative materials and laboratory techniques, tooth arrangement and maxillomandibular relations, and implant dentistry. This paper reviews some of the literature on these areas during this period. PMID:8401825

  7. Central retinal vein occlusion in a migraine patient.

    PubMed

    Benninger, Felix; Saban, Tal; Steiner, Israel

    2015-11-01

    We describe a 31-year-old woman with a history of migraines without aura, who presented to our emergency department due to a monocular visual disturbance. This was misdiagnosed as being related to her migraine, however, it was subsequently found to be caused by a central retinal vein occlusion. Patients suffering from migraine can experience visual disturbances in the form of auras. The neuropathological basis for this phenomenon is thought to be a spreading depression in the visual cortex, causing a hemifield active visual phenomenon. Missing the diagnosis of central retinal vein occlusion is common, especially in the setting of an initially normal fundoscopy examination. PMID:26115899

  8. Transcatheter patch occlusion of perimembranous ventricular septal defects.

    PubMed

    Sideris, Eleftherios B; Macuil, Benjamin; Varvarenko, Victor; Toumanides, Savvas

    2005-06-15

    Sixteen surgical candidates for ventricular septal defect correction were brought to the catheterization laboratory for transcatheter patch occlusion. There were 3 cases of nonrestrictive ventricular septal defects, including 2 with malalignment (tetralogy of Fallot). All patients, except those with tetralogy of Fallot who were cyanotic, had large left-right shunts. They were all corrected through the femoral vein. All defects with the exception of 2 were successfully occluded (12 full occlusions, 2 residual shunts). On follow-up, there were no embolizations, aortic insufficiency, or other complications. The method appears effective and relatively safe, and could challenge the current surgical standard of treatment. PMID:15950588

  9. See-through integral imaging display with background occlusion capability.

    PubMed

    Yamaguchi, Yuta; Takaki, Yasuhiro

    2016-01-20

    Background occlusion capability is provided to a flat-panel-type integral imaging display that has a transparent screen and can superimpose three-dimensional (3D) images on real scenes. A symmetric integral imaging system that comprises two integral imaging systems connected by an additional lens array, is proposed. Elementary images are displayed on a flat-panel display on one integral imaging system to generate 3D images, and the occlusion mask patterns are displayed on a flat-panel display on the other integral imaging system to selectively block rays from background scenes. The proposed system was constructed and experimentally verified. PMID:26835946

  10. Mechanisms of Biliary Plastic Stent Occlusion and Efforts at Prevention.

    PubMed

    Kwon, Chang-Il; Lehman, Glen A

    2016-03-01

    Biliary stenting via endoscopic retrograde cholangiopancreatography has greatly improved the quality of patient care over the last 30 years. Plastic stent occlusion limits the life span of such stents. Attempts to improve plastic stent patency duration have mostly failed. Metal stents (self-expandable metal stents [SEMSs]) have therefore replaced plastic stents, especially for malignant biliary strictures. SEMS are at least 10 times more expensive than plastic stents. In this focused review, we will discuss basic mechanisms of plastic stent occlusion, along with a systematic summary of previous efforts and related studies to improve stent patency and potential new techniques to overcome existing limitations. PMID:27000422

  11. Visualisation of urban airborne laser scanning data with occlusion images

    NASA Astrophysics Data System (ADS)

    Hinks, Tommy; Carr, Hamish; Gharibi, Hamid; Laefer, Debra F.

    2015-06-01

    Airborne Laser Scanning (ALS) was introduced to provide rapid, high resolution scans of landforms for computational processing. More recently, ALS has been adapted for scanning urban areas. The greater complexity of urban scenes necessitates the development of novel methods to exploit urban ALS to best advantage. This paper presents occlusion images: a novel technique that exploits the geometric complexity of the urban environment to improve visualisation of small details for better feature recognition. The algorithm is based on an inversion of traditional occlusion techniques.

  12. Retinal arterial occlusive disease in systemic lupus erythematosus.

    PubMed

    Gold, D; Feiner, L; Henkind, P

    1977-09-01

    Four patients with systemic lupus erythematosus (SLE) developed an unusual form of occlusive retinal arterial disease. The most prominent clinical features of this disorder were deposition of yellow-white material in retinal arterial walls and evidence of multifocal retinal arterial occlusion. Fluorescein angiographic findings included nonperfusion of the obstructed arteries and the retinal capillary beds fed by them, and fluorescein leakage at the sites of involvement of the retinal arteries. This ocular complication of SLE is presumably a manifestation of the widespread systemic vascular problems seen in this disorder. It may be more common in patients with lupus involving the CNS. PMID:901267

  13. Sinus bradycardia as a predictor of right coronary artery occlusion in patients with inferior myocardial infarction.

    PubMed

    Serrano, C V; Bortolotto, L A; César, L A; Solimene, M C; Mansur, A P; Nicolau, J C; Ramires, J A

    1999-01-01

    Differentiation of right coronary artery (RCA) from left circumflex artery (LCxA) occlusion may be difficult since both can present an electrocardiographic pattern of inferior myocardial infarction (IMI). We studied 133 patients with IMI, 92 patients with RCA occlusion and 41 patients with LCxA occlusion. Risk factors such as previous MI, arterial hypertension, diabetes, smoking, and dislipemia, were similar for RCA and LCxA occlusions. Patients with RCA occlusion had a higher incidence of isolated IMI than patients with LCxA occlusion, 50% vs. 17%, respectively (P<0.001). Arterial hypotension was more prevalent (P<0.05) among patients with RCA (18%) rather than those with LCxA occlusion (2%). RCA occlusion presented an association with sinus bradycardia, an association not observed with LCxA occlusion (15% vs. 0%, respectively; P<0.01). Total atrioventricular block was only present among patients with RCA (18%). Proximal occlusions of the RCA presented lower heart rates (sinus bradycardia) than medial and distal occlusions (13% vs. 1% and 1%, respectively; P<0.0001 and P<0.001). Therefore, regarding patients with IMI: (1) sinus bradycardia is more frequent when the infarct-related artery is the RCA; (2) proximal occlusions of the right coronary predispose low heart rates; and (3) occlusion of the LCxA rarely induces sinus bradycardia. PMID:10077404

  14. Transient Aortic Occlusion Augments Collateral Blood Flow and Reduces Mortality During Severe Ischemia due to Proximal Middle Cerebral Artery Occlusion.

    PubMed

    Ramakrishnan, Gomathi; Dong, Bin; Todd, Kathryn G; Shuaib, Ashfaq; Winship, Ian R

    2016-04-01

    Cerebral collateral circulation provides alternative vascular routes for blood to reach ischemic tissues during stroke. Collateral therapeutics attempt to augment flow through these collateral channels to reduce ischemia and brain damage during acute ischemic stroke. Transient aortic occlusion (TAO) has pre-clinical data suggesting that it can augment collateral blood flow and clinical data suggesting a benefit for patients with moderate cortical strokes. By diverting blood from the periphery towards the cerebral circulation, TAO has the potential to augment primary collateral flow at the circle of Willis and thereby improve outcome even during large, hemispheric strokes. Using proximal middle and anterior cerebral artery occlusion in rats, we demonstrate that TAO reduces mortality and improves collateral blood flow in severely ischemic animals. As such, TAO may be an effective therapy to reduce early mortality during severe ischemia associated with proximal occlusions. PMID:26706246

  15. Effects of resistance training combined with vascular occlusion or hypoxia on neuromuscular function in athletes.

    PubMed

    Manimmanakorn, Apiwan; Manimmanakorn, Nuttaset; Taylor, Robert; Draper, Nick; Billaut, Francois; Shearman, Jeremy P; Hamlin, Michael J

    2013-07-01

    The aim was to investigate the effects of low-load resistant training combined with vascular occlusion or normobaric hypoxic exposure, on neuromuscular function. In a randomised controlled trial, well-trained athletes took part in a 5-week training of knee flexor/extensor muscles in which low-load resistant exercise (20% of one repetition maximum, 1-RM) was combined with either (1) an occlusion pressure of approximately 230 mmHg (KT, n = 10), (2) hypoxic air to generate an arterial blood oxygen saturation of ~80% (HT, n = 10), or (3) with no additional stimulus (CT, n = 10). Before and after training, participants completed the following tests: 3-s maximal voluntary contraction (MVC₃), 30-s MVC, and an endurance test (maximal number of repetitions at 20% 1-RM, Reps₂₀). Electromyographic activity (root mean square, RMS) was measured during tests and the cross-sectional area (CSA) of the quadriceps and hamstrings was measured pre- and post-training. Relative to CT, KT, and HT showed likely increases in MVC₃ (11.0 ± 11.9 and 15.0 ± 13.1%, mean ± 90% confidence interval), MVC₃₀ (10.2 ± 9.0 and 18.3 ± 17.4%), and Reps₂₀ (28.9 ± 23.7 and 23.3 ± 24.0%). Compared to the CT group, CSA increased in the KT (7.6 ± 5.8) and HT groups (5.3 ± 3.0). KT had a large effect on RMS during MVC₃, compared to CT (effect size 0.8) and HT (effect size 0.8). We suspect hypoxic conditions created within the muscles during vascular occlusion and hypoxic training may play a key role in these performance enhancements. PMID:23412543

  16. Emergency endovascular revascularization of tandem occlusions: Internal carotid artery dissection and intracranial large artery embolism.

    PubMed

    Cohen, José E; Leker, Ronen R; Eichel, Roni; Gomori, Moshe; Itshayek, Eyal

    2016-06-01

    Internal carotid artery dissection (ICAD) with concomitant occlusive intracranial large artery emboli is an infrequent cause of acute stroke, with poor response to intravenous thrombolysis. Reports on the management of this entity are limited. We present our recent experience in the endovascular management of occlusive ICAD and major intracranial occlusion. Consecutive anterior circulation acute stroke patients meeting Medical Center criteria for endovascular management of ICAD from June 2011 to June 2015 were included. Clinical, imaging, and procedure data were collected retrospectively under Institutional Review Board approval. The endovascular procedure for carotid artery revascularization and intracranial stent thrombectomy is described. Six patients met inclusion criteria (National Institutes of Health Stroke Scale score 12-24, time from symptom onset 2-8hours). Revascularization of the extracranial carotid dissection and stent thrombectomy were achieved in 5/6 patients, resulting in complete recanalization (Thrombolysis in Myocardial Infarction flow grade 3 in a mean 2.7hours), and modified Rankin Scale score 0-2 at 90 day follow-up. In one patient, attempts to microcatheterize the true arterial lumen failed and thrombectomy was therefore not feasible. No arterial dissection, arterial rupture or accidental stent detachment occurred, and there was no intracerebral hemorrhage or hemorrhagic transformation. Our preliminary data on this selected subgroup of patients suggest the presented approach is safe, feasible in a significant proportion of patients, and efficacious in achieving arterial recanalization and improving patient outcome. Crossing the dissected segment remains the most important limiting factor in achieving successful ICA recanalization. Further evaluation in larger series is warranted. PMID:26924182

  17. Composite membrane with integral rim

    SciTech Connect

    Routkevitch, Dmitri; Polyakov, Oleg G

    2015-01-27

    Composite membranes that are adapted for separation, purification, filtration, analysis, reaction and sensing. The composite membranes can include a porous support structure having elongate pore channels extending through the support structure. The composite membrane also includes an active layer comprising an active layer material, where the active layer material is completely disposed within the pore channels between the surfaces of the support structure. The active layer is intimately integrated within the support structure, thus enabling great robustness, reliability, resistance to mechanical stress and thermal cycling, and high selectivity. Methods for the fabrication of composite membranes are also provided.

  18. Membrane Processes.

    PubMed

    Pellegrin, Marie-Laure; Sadler, Mary E; Greiner, Anthony D; Aguinaldo, Jorge; Min, Kyungnan; Zhang, Kai; Arabi, Sara; Burbano, Marie S; Kent, Fraser; Shoaf, Robert

    2015-10-01

    This review, for literature published in 2014, contains information related to membrane processes for municipal and industrial applications. This review is a subsection of the Treatment Systems section of the annual Water Environment Federation literature review and covers the following topics: pretreatment, membrane bioreactor (MBR) configuration, design, nutrient removal, operation, industrial treatment, fixed film and anaerobic membrane systems, reuse, microconstituents removal, membrane technology advances, membrane fouling, and modeling. Other sub-sections of the Treatment Systems section that might relate to this literature review include: Biological Fixed-Film Systems, Activated Sludge and Other Aerobic Suspended Culture Processes, Anaerobic Processes, Water Reclamation and Reuse. The following sections might also have related information on membrane processes: Industrial Wastes, Hazardous Wastes, and Fate and Effects of Pollutants. PMID:26420079

  19. Membrane Processes.

    PubMed

    Pellegrin, Marie-Laure; Burbano, Marie S; Sadler, Mary E; Diamond, Jason; Baker, Simon; Greiner, Anthony D; Arabi, Sara; Wong, Joseph; Doody, Alexandra; Padhye, Lokesh P; Sears, Keith; Kistenmacher, Peter; Kent, Fraser; Tootchi, Leila; Aguinaldo, Jorge; Saddredini, Sara; Schilling, Bill; Min, Kyungnan; McCandless, Robert; Danker, Bryce; Gamage, Neranga P; Wang, Sunny; Aerts, Peter

    2016-10-01

    This review, for literature published in 2015, contains information related to membrane processes for municipal and industrial applications. This review is a subsection of the Treatment Systems section of the annual Water Environment Federation literature review and covers the following topics: pretreatment, membrane bioreactor (MBR) configuration, design, nutrient removal, operation, industrial treatment, anaerobic membrane systems, reuse, microconstituents removal, membrane technology advances, membrane fouling, and modeling. Other sub-sections of the Treatment Systems section that might relate to this literature review include: Biological Fixed-Film Systems, Activated Sludge and Other Aerobic Suspended Culture Processes, Anaerobic Processes, Water Reclamation and Reuse. The following sections might also have related information on membrane processes: Industrial Wastes, Hazardous Wastes, and Fate and Effects of Pollutants. PMID:27620084

  20. Occlusal Caries Management: Preferences among Dentists in Norway.

    PubMed

    Kopperud, Simen E; Tveit, Anne B; Opdam, Niek J M; Espelid, Ivar

    2016-01-01

    The aim was to measure variations in the threshold for operative treatment of occlusal caries in permanent teeth and the use of dental materials, compared with results from a similar study conducted in Norway in 1995. In 2009, a precoded questionnaire was sent electronically to 3,654 dentists with E-mail addresses in the member register of the Norwegian Dental Association. The questions were related to caries, treatment strategies and choice of dental materials. Replies were obtained from 61.3% respondents after two reminders. Restorative treatment of occlusal lesions confined to enamel was proposed by 12% of the dentists, compared with 18% in 1995 (p < 0.01). Older dentists more often than younger dentists would operatively treat enamel lesions (p < 0.01). Most dentists preferred to drill only the carious part of the fissure rather than the whole fissure both in 2009 (78.8%) and 1995 (68.3%; p < 0.01). In 2009, 91.9% preferred composite as the restorative material of choice, compared to only 39.1% in 1995. Logistic regression analyses identified higher age of the dentist as the only variable significantly associated with higher risk of restoring occlusal enamel lesions operatively. The authors conclude that especially young dentists appear to be more reluctant to remove tooth substance in 2009 compared with 1995. Composite is the dominating material of choice in 2009 and seems to have substituted the use of most other filling materials in occlusal restorations in permanent teeth. PMID:26839953

  1. Hidden in Plain Sight: Occlusion in Pedagogical Genres

    ERIC Educational Resources Information Center

    Neaderhiser, Stephen E.

    2016-01-01

    Occluded genres in academia work "behind the scenes" to support and develop an academic's professional identity. However, while significant attention has been paid to occluded genres that support an academic's identity as a researcher, very little scholarship examines how occlusion operates in genres of pedagogy, such as the syllabus,…

  2. Centric slide in different Angle's classes of occlusion.

    PubMed

    Čimić, Samir; Badel, Tomislav; Šimunković, Sonja Kraljević; Pavičin, Ivana Savić; Ćatić, Amir

    2016-01-01

    The purpose of this study was to test the possible differences in centric slide values between different Angle's classes of occlusion. The study included 98 participants divided into four groups: Angle's class I, Angle's class II, subdivision 1, Angle's class II, subdivision 2 and Angle's class III. All recordings were obtained using an ultrasound jaw tracking device with six degrees of freedom. The distance between the maximum intercuspation (reference position) and the centric occlusion was recorded at the condylar level. Anteroposterior, superoinferior and transversal distance of the centric slide were calculated for each participant, and the data were statistically analyzed (analysis of variance and Newman-Keuls post hoc test). No statistically significant difference was found in the anteroposterior and transversal distance of the centric slide between tested groups, while Angle's class II, subdivision 2 showed smaller vertical amount of the centric slide compared to Angle's class I and class II, subdivision 1. None of the 98 participants showed coincidence of centric occlusion and maximum intercuspation. Our results suggest that coincidence of the maximum intercuspation with the centric occlusion should not be expected. Smaller extent of the vertical distance of the centric slide could be morphological and a functional expression characteristic of the Angle's class II, subdivision 2. PMID:26434757

  3. Learning about Occlusion: Initial Assumptions and Rapid Adjustments

    ERIC Educational Resources Information Center

    Kochukhova, Olga; Gredeback, Gustaf

    2007-01-01

    We examined 6-month-olds' abilities to represent occluded objects, using a corneal-reflection eye-tracking technique. Experiment 1 compared infants' ability to extrapolate the current pre-occlusion trajectory with their ability to base predictions on recent experiences of novel object motions. In the first condition infants performed at asymptote…

  4. Young Infants' Perception of Unity and Form in Occlusion Displays.

    ERIC Educational Resources Information Center

    Johnson, Scott P.; Bremner, J. Gavin; Slater, Alan M.; Mason, Uschi C.; Foster, Kirsty

    2002-01-01

    A recognition-based paradigm was used to investigate possibility that past research failed to sensitively assess infants' perception of the unity of misaligned edges in partial occlusion displays. Results suggested that habituation designs tapping recognition processes may be particularly efficacious in revealing infants' perceptual organization.…

  5. Efficient Detection of Occlusion prior to Robust Face Recognition

    PubMed Central

    Dugelay, Jean-Luc

    2014-01-01

    While there has been an enormous amount of research on face recognition under pose/illumination/expression changes and image degradations, problems caused by occlusions attracted relatively less attention. Facial occlusions, due, for example, to sunglasses, hat/cap, scarf, and beard, can significantly deteriorate performances of face recognition systems in uncontrolled environments such as video surveillance. The goal of this paper is to explore face recognition in the presence of partial occlusions, with emphasis on real-world scenarios (e.g., sunglasses and scarf). In this paper, we propose an efficient approach which consists of first analysing the presence of potential occlusion on a face and then conducting face recognition on the nonoccluded facial regions based on selective local Gabor binary patterns. Experiments demonstrate that the proposed method outperforms the state-of-the-art works including KLD-LGBPHS, S-LNMF, OA-LBP, and RSC. Furthermore, performances of the proposed approach are evaluated under illumination and extreme facial expression changes provide also significant results. PMID:24526902

  6. Three hypothesis algorithm with occlusion reasoning for multiple people tracking

    NASA Astrophysics Data System (ADS)

    Reta, Carolina; Altamirano, Leopoldo; Gonzalez, Jesus A.; Medina-Carnicer, Rafael

    2015-01-01

    This work proposes a detection-based tracking algorithm able to locate and keep the identity of multiple people, who may be occluded, in uncontrolled stationary environments. Our algorithm builds a tracking graph that models spatio-temporal relationships among attributes of interacting people to predict and resolve partial and total occlusions. When a total occlusion occurs, the algorithm generates various hypotheses about the location of the occluded person considering three cases: (a) the person keeps the same direction and speed, (b) the person follows the direction and speed of the occluder, and (c) the person remains motionless during occlusion. By analyzing the graph, our algorithm can detect trajectories produced by false alarms and estimate the location of missing or occluded people. Our algorithm performs acceptably under complex conditions, such as partial visibility of individuals getting inside or outside the scene, continuous interactions and occlusions among people, wrong or missing information on the detection of persons, as well as variation of the person's appearance due to illumination changes and background-clutter distracters. Our algorithm was evaluated on test sequences in the field of intelligent surveillance achieving an overall precision of 93%. Results show that our tracking algorithm outperforms even trajectory-based state-of-the-art algorithms.

  7. Delayed Axillary Artery Occlusion after Reverse Total Shoulder Arthroplasty

    PubMed Central

    Heitmiller, Richard F.

    2016-01-01

    Axillary artery injury has been associated with shoulder dislocation and surgery. We describe a case of delayed axillary artery occlusion after reverse total shoulder arthroplasty. The injury was confirmed by Doppler and angiography and was treated with angioplasty and stenting. Early recognition and treatment of this injury are mandatory for patients' recovery. PMID:27555975

  8. Sex Differences during Visual Scanning of Occlusion Events in Infants

    ERIC Educational Resources Information Center

    Wilcox, Teresa; Alexander, Gerianne M.; Wheeler, Lesley; Norvell, Jennifer M.

    2012-01-01

    A growing number of sex differences in infancy have been reported. One task on which they have been observed reliably is the event-mapping task. In event mapping, infants view an occlusion event involving 1 or 2 objects, the occluder is removed, and then infants see 1 object. Typically, boys are more likely than girls to detect an inconsistency…

  9. Overcoming the challenge of venous occlusion for lead implantation

    PubMed Central

    Burri, Haran

    2015-01-01

    Vein stenosis or occlusion is a frequent finding in patients with previously-implanted transvenous leads. This editorial describes the different techniques that may be used to overcome this hurdle in case a new lead needs to be implanted, and discusses two case reports in this issue of the journal. PMID:26937095

  10. Multicomponent membranes

    DOEpatents

    Kulprathipanja, Santi; Kulkarni, Sudhir S.; Funk, Edward W.

    1988-01-01

    A multicomponent membrane which may be used for separating various components which are present in a fluid feed mixture comprises a mixture of a plasticizer such as a glycol and an organic polymer cast upon a porous organic polymer support. The membrane may be prepared by casting an emulsion or a solution of the plasticizer and polymer on the porous support, evaporating the solvent and recovering the membrane after curing.

  11. A cardiovascular occlusion method based on the use of a smart hydrogel.

    PubMed

    Jackson, Nathan; Verbrugghe, Peter; Cuypers, Dieter; Adesanya, Kenneth; Engel, Leeya; Glazer, Piotr; Dubruel, Peter; Shacham-Diamand, Yosi; Mendes, Eduardo; Herijgers, Paul; Stam, Frank

    2015-02-01

    Smart hydrogels for biomedical applications are highly researched materials. However, integrating them into a device for implantation is difficult. This paper investigates an integrated delivery device designed to deliver an electro-responsive hydrogel to a target location inside a blood vessel with the purpose of creating an occlusion. The paper describes the synthesis and characterization of a Pluronic/methacrylic acid sodium salt electro-responsive hydrogel. Application of an electrical bias decelerates the expansion of the hydrogel. An integrated delivery system was manufactured to deliver the hydrogel to the target location in the body. Ex vivo and in vivo experiments in the carotid artery of sheep were used to validate the concept. The hydrogel was able to completely occlude the blood vessel reducing the blood flow from 245 to 0 ml/min after implantation. Ex vivo experiments showed that the hydrogel was able to withstand physiological blood pressures of > 270 mm·Hg without dislodgement. The results showed that the electro-responsive hydrogel used in this paper can be used to create a long-term occlusion in a blood vessel without any apparent side effects. The delivery system developed is a promising device for the delivery of electro-responsive hydrogels. PMID:25203979

  12. Risk Factors and Treatment Strategies in Patients With Retinal Vascular Occlusions.

    PubMed

    Chapin, John; Carlson, Karen; Christos, Paul J; DeSancho, Maria Teresa

    2015-10-01

    Retinal vein occlusion (RVO) and retinal artery occlusion (RAO) cause significant visual impairment. The role of thrombophilia and cardiovascular testing is uncertain, and optimal treatment strategies have not been determined. We reviewed medical records of 39 patients with RVO and RAO (23 women and 16 men). Thrombophilia and cardiovascular evaluations were performed and outcomes were reviewed. In all, 24 (61.5%) patients had at least 1 thrombophilia. Elevated factor VIII levels were found in RVO (n = 5) but not in RAO. There are no other significant differences in thrombophilias in RVO compared to those in RAO. Most patients had hypertension(41.2% RAO and 55% RVO) and hyperlipidemia (35.5% RAO and 81.8% RVO). In all, 4 women were using oral contraceptives, 2 were pregnant or postpartum. Follow-up data was available for 28 patients (13 RAO, 15 RVO). Nineteen were treated with aspirin, four with warfarin, and one with low molecular weight heparin. Eight patients reported improvement in vision at time of follow-up (5 RAO, 3 RVO). Multiple risk factors are associated with RVO and RAO, and a complete assessment should include thrombophilia and cardiovascular studies. PMID:24335246

  13. Computed tomography findings of hepatic veno-occlusive disease caused by Sedum aizoon with histopathological correlation

    PubMed Central

    Shao, H.; Chen, H. Z.; Zhu, J. S.; Ruan, B.; Zhang, Z. Q.; Lin, X.; Gan, M. F.

    2015-01-01

    This study investigated the value of computed tomography (CT) in the diagnosis and treatment of hepatic veno-occlusive disease (HVOD) caused by Sedum aizoon (SA). The clinical manifestations, treatment results, imaging findings, and histological findings of the liver were analyzed in 39 patients with HVOD caused by SA. Hepatomegaly, liver dysfunction, abdominal effusion, and geographic density changes on liver CT scans were found in all 39 patients. The pathological findings of histological liver examination included swelling and point-like necrosis of liver cells, significant expansion and congestion of the sinuses, endothelial swelling, and wall thickening with incomplete lumen occlusion of small liver vessels. CT geographic density changes were confirmed by histological examination of the liver in 18 patients. Sixteen patients with small amounts of ascites that started within 4 weeks of treatment recovered completely or significantly improved after symptomatic and supportive treatment. However, only 43.75% of the patients with larger amounts of ascites improved following symptomatic and supportive treatment. In conclusion, liver CT examination is a valuable, safe, and noninvasive tool for the diagnosis of HVOD caused by SA. In selected cases, liver CT examination may replace liver biopsy and histological analysis. PMID:26517336

  14. Gemcitabine-Induced Pulmonary Toxicity: A Case Report of Pulmonary Veno-Occlusive Disease

    PubMed Central

    Turco, Célia; Jary, Marine; Kim, Stefano; Moltenis, Mélanie; Degano, Bruno; Manzoni, Philippe; Nguyen, Thierry; Genet, Bruno; Rabier, Marie-Blanche Valnet; Heyd, Bruno; Borg, Christophe

    2015-01-01

    INTRODUCTION Gemcitabine is a chemotherapeutic agent frequently used by for the treatment of several malignancies both in the adjuvant and metastatic setting. Although myelosuppression is the most adverse event of this therapy, gemcitabine might induce severe pulmonary toxicities. We describe a case of pulmonary veno-occlusive disease (PVOD) related to gemcitabine. CASE PRESENTATION The patient was an 83-year-old man with a metastatic pancreatic cancer who was treated by gemcitabine as first-line therapy. He was in good health and received no other chemotherapy. A dose of 1000 mg/m2 of gemcitabine was administered over a 30-minute intravenous infusion on days 1, 8, and 15 of a 28-day cycle. After a period of 6 months, a complete response was observed. Nevertheless, the patient developed a severe dyspnea, with arterial hypoxemia and very low lung diffusion for carbon monoxide. A CT scan showed diffuse ground glass opacities with septal lines, bilateral pleural effusion, and lymph node enlargement. On echocardiography, there was a suspicion of pulmonary hypertension with elevated systolic pulmonary artery pressure and normal left ventricular pressures. Right heart catheterization confirmed pulmonary hypertension and normal pulmonary artery occlusion pressure. Diagnosis of PVOD was made, and a gemcitabine-induced toxicity was suspected. A symptomatic treatment was started. At last follow-up, patient was in functional class I with near-normal of CT scan, arterial blood gases, and echocardiography. A gemcitabine-induced PVOD is the more likely diagnosis. PMID:26380562

  15. Genome sequence of an Adoxophyes orana granulovirus (AdorGV) occlusion body morphology mutant

    Technology Transfer Automated Retrieval System (TEKTRAN)

    - Genome sequence of an Adoxophyes orana granulovirus (AdorGV) occlusion body morphology mutant Baculoviruses package virus particles in a crystalline matrix of viral protein to form occlusion bodies. Occlusion bodies are used in biological control because the crystalline matrix protects the viral ...

  16. History of materials used for recording static and dynamic occlusal contact marks: a literature review

    PubMed Central

    Rahul, G R.; Poduval, Soorya T.; Shetty, Karunakar; Gupta, Bhawna; Rajora, Varun

    2013-01-01

    In the discipline of prosthetic dentistry it is important not only to examine the occlusion, but to be able to record, store, and transfer the information. Over the years many occlusion testing materials have been used. It has been suggested the clinical recording and transfer of information using waxes and other occlusion recording materials have disadvantages relating to inaccuracy and problems of manipulation. Therefore, there has been introduction of many new systems for recording occlusion contacts to overcome such problems. The correct physiological recovery of occlusion posses as much a challenge as ever for every dentist and technician. Even the smallest high spots measuring just a few microns can cause dysfunctions like temporo-mandibular pain. Occlusal proportions are being constantly changed with every procedure. Therefore, an understanding of the synergy of the teeth in static and dynamic occlusion forms the basis of good dentistry. The purpose of this review article is to give and overview of the various materials and methods that have been used to record occlusal contact marks. Key words:Occlusal contact marks, Occlusion indicators, Occlusion test materials, Occlusion recording materials. PMID:24455051

  17. Catalytic nanoporous membranes

    DOEpatents

    Pellin, Michael J.; Hryn, John N.; Elam, Jeffrey W.

    2009-12-01

    A nanoporous catalytic membrane which displays several unique features including pores which can go through the entire thickness of the membrane. The membrane has a higher catalytic and product selectivity than conventional catalysts. Anodic aluminum oxide (AAO) membranes serve as the catalyst substrate. This substrate is then subjected to Atomic Layer Deposition (ALD), which allows the controlled narrowing of the pores from 40 nm to 10 nm in the substrate by deposition of a preparatory material. Subsequent deposition of a catalytic layer on the inner surfaces of the pores reduces pore sizes to less than 10 nm and allows for a higher degree of reaction selectivity. The small pore sizes allow control over which molecules enter the pores, and the flow-through feature can allow for partial oxidation of reactant species as opposed to complete oxidation. A nanoporous separation membrane, produced by ALD is also provided for use in gaseous and liquid separations. The membrane has a high flow rate of material with 100% selectivity.

  18. Neuroprotective efficacy of lifarizine (RS-87476) in a simplified rat survival model of 2 vessel occlusion.

    PubMed Central

    McBean, D. E.; Winters, V.; Wilson, A. D.; Oswald, C. B.; Alps, B. J.; Armstrong, J. M.

    1995-01-01

    kg-1 i.p.) at identical time points. 6. Histopathological damage was assessed, from cresyl violet and haematoxyline/eosin stained sections, using a scoring system of 0-6 (no damage-complete neuronal death). The dosing regimen of lifarizine gave reduced damage in the hippocampal CA1 sub-field (4.1 +/- 0.3 to 2.8 +/- 0.6) and striatum (1.7 +/- 0.3 to 1.2 +/- 0.3) and significant neuroprotection in the anterior cortex (2.0 +/- 0.2 to 1.2 +/- 0.2; p < 0.05), thalamus (1.5 +/- 0.2 to 0.8 +/- 0.2; p < 0.01), posterior cortex (1.5 +/- 0.2 to 1.0 +/- 0.2; p < 0.05) and cerebellar brain stem (0.9 +/- 0.2 to 0.4 +/- 0.1; p < 0.01). The overall mean brain score was significantly reduced (from 1.5 +/- 0.1 to 0.9 +/- 0.2). 7. These data show that the newly modified 2 vessel occlusion model produced a quantifiable level of ischaemic damage and that the novel agent lifarizine is neuroprotective in the model. Images Figure 2 PMID:8719782

  19. Tissue microcirculation measured by vascular occlusion test during anesthesia induction.

    PubMed

    Kim, Tae Kyong; Cho, Youn Joung; Min, Jeong Jin; Murkin, John M; Bahk, Jae-Hyon; Hong, Deok Man; Jeon, Yunseok

    2016-02-01

    Tissue microcirculation measured by vascular occlusion test is impaired during septic shock. However, it has not been investigated extensively during anesthesia induction. The aim of the study is to evaluate tissue microcirculation during anesthesia induction. We hypothesized that during anesthesia induction, tissue microcirculation measured by vascular occlusion test might be enhanced with peripheral vasodilation during anesthesia induction. We conducted a prospective observational study of 50 adult patients undergoing cardiac surgery. During anesthesia induction, we measured and analyzed tissue oxygen saturation, vascular occlusion test, cerebral oximetry, forearm-minus-fingertip skin temperature gradients and hemodynamic data in order to evaluate microcirculation as related to alterations in peripheral vasodilation as reflected by increased Tforearm-finger thermal gradients. During anesthesia induction, recovery slope during vascular occlusion test and cerebral oxygen saturation increased from 4.0 (1.5) to 4.7 (1.3) % s(-1) (p = 0.02) and 64.0 (10.2) to 74.2 (9.2) % (p < 0.001), respectively. Forearm-minus-fingertip skin temperature gradients decreased from 1.9 (2.9) to -1.4 (2.2) °C (p < 0.001). There was an inverse correlation between changes in the skin temperature gradients and changes in cerebral oximetry (r = 0.33; p = 0.02). During anesthesia induction, blood pressure and forearm-minus-fingertip skin temperature gradients decrease while cerebral oximetry and vascular occlusion test recovery slope increase. These findings suggest that anesthesia induction increases tissue microcirculation with peripheral vasodilation. PMID:25750016

  20. Sclerostin is essential for alveolar bone loss in occlusal hypofunction

    PubMed Central

    XU, YANG; WANG, LUFEI; SUN, YAO; HAN, XIANGLONG; GAO, TIAN; XU, XIN; CHEN, TIAN; ZHAO, XUEFENG; ZENG, HUAN; WANG, YANMIN; BAI, DING

    2016-01-01

    Bone loss is caused by occlusal hypofunction and is a serious health concern. This is particularly true of tooth loss, which is common in the elderly. However, the cellular and molecular mechanisms underlying bone loss have yet to be fully elucidated. Sclerostin and Wnt/β-catenin signaling have previously been reported to serve important roles in regulating bone remodeling. Therefore, the present study aimed to investigate the involvement of sclerostin and Wnt/β-catenin signaling in occlusal hypofunction-induced alveolar bone remodeling. The unilateral maxillary molars of 14 male Sprague-Dawley rats were extracted in order to establish a model of occlusal hypofunction. For each rat, the non-extraction side was treated as the control group for comparisons with the extraction side. At 8 weeks after tooth extraction, the rats were sacrificed and alveolar bone specimens were harvested for X-ray radiography, micro-computed tomography (CT) and histological and immunohistochemical examinations. Bone loss and architecture deterioration were observed at the occlusal hypofunction side. The bone mineral density was markedly decreased and the ratio of bone volume to total volume was significantly decreased at the hypofunction side, as compared with the control side (P<0.001). In addition, the number of osteoclasts at the hypofunction side were significantly increased compared with that in the control side (P<0.001), as demonstrated using tartrate-resistant acid phosphatase staining. Furthermore, the protein expression levels of sclerostin and receptor activator of nuclear factor-κB ligand were increased, whereas those of β-catenin were decreased, at the hypofunction side when compared with the control side. In conclusion, the results of the present study suggested that occlusal hypofunction-induced bone loss may be associated with upregulated expression of sclerostin, which, in turn, may inhibit the activity of the Wnt/β-catenin signaling pathway. PMID:27168809

  1. Retrograde Approach Using Surgical Cutdown Technique for Limb Salvage in a Case of Critical Limb Ischemia With Severely Calcified Tibial Occlusive Disease.

    PubMed

    Shiraki, Tatsuya; Iida, Osamu; Suemitsu, Kotaro; Tsuji, Yoriko; Uematsu, Masaaki

    2016-05-01

    We here report a successful angioplasty for tibial artery occlusion using direct tibial puncture and subsequent retrograde approach under surgical cutdown technique. An 82-year-old man with ulcer/gangrene in first and second digits was referred to our hospital for endovascular therapy (EVT) of lower extremity ischemia. Diagnostic angiogram revealed anterior tibial artery (ATA) occlusion with severe calcification. Subintimal angioplasty was attempted using a 0.014-inch hydrophilic guidewire but was unsuccessful. A retrograde approach was subsequently attempted for ATA recanalization. However, because of severe calcification of dorsal pedis artery (DPA), percutaneous distal puncture was also unsuccessful. Direct puncture under surgical cutdown technique for DPA was subsequently performed and was successful. A 0.014-inch hydrophilic wire was advanced in retrograde fashion across the ATA occlusion and was used to access the microcatheter positioned at the proximal ATA via antegrade approach. Angioplasty of the ATA occlusion was performed using a 2.5-/3.0-mm tapered balloon. Completion angiogram revealed restoration of flow without dissection. Skin perfusion pressure was dramatically improved. Complete wound healing was achieved 5 months after EVT. PMID:27207678

  2. Assessment of the attenuation of an intra-abdominal vein by use of a silicone-polyacrylic acid gradual venous occlusion device in dogs and cats.

    PubMed

    Wallace, Mandy L; Ellison, Gary W; Giglio, Robson F; Batich, Christopher D; Berry, Clifford R; Case, J Brad; Kim, Stanley E

    2016-06-01

    OBJECTIVE To evaluate the closure rate and completeness of closure for a silicone-polyacrylic acid gradual venous occlusion device placed around an intra-abdominal vein to simulate gradual occlusion of an extrahepatic portosystemic shunt. ANIMALS 3 purpose-bred cats and 2 purpose-bred dogs. PROCEDURES The device was surgically placed around an external (cats) or internal (dogs) iliac vein. Computed tomographic angiography was performed at the time of surgery and 2, 4, and 6 weeks after surgery. Ultrasonographic examinations of blood flow through the vein within the device were performed at the time of surgery and at weekly intervals thereafter. Dogs were euthanized 6 weeks after surgery, and the external iliac veins were harvested for histologic examination. RESULTS The prototype gradual venous occlusion device was successfully placed in all animals, and all animals recovered without complications following the placement procedure. The vessel was completely occluded in 2 cats by 6 weeks after surgery, as determined on the basis of results of CT and ultrasonography; there was incomplete occlusion with a luminal diameter of 1.5 mm in the other cat by 6 weeks after surgery. The vessel was completely occluded in both dogs by 6 weeks after surgery. Histologic examination of the external iliac veins obtained from the dogs revealed minimal inflammation of the vessel wall and no thrombus formation. CONCLUSIONS AND CLINICAL RELEVANCE The prototype device induced gradual attenuation of an intra-abdominal vessel over a 6-week period. This device may provide another option for gradual occlusion of extrahepatic portosystemic shunts. PMID:27227505

  3. Endovascular occlusion of intracranial aneurysms with electrically detachable coils: Correlation of aneurysm neck size and treatment results

    SciTech Connect

    Zubillaga, A.F.; Guglielmi, G.; Vinuela, F.; Duckwiler, G.R.

    1994-05-01

    To devise a method to measure aneurysm neck size on angiographic films, and to correlate the sizes obtained with the extent of endovascular aneurysm occlusion, performed with electrically detachable coils. The angiograms of 79 intracranial aneurysms treated by endovascular occlusion using electrically detachable coils were retrospectively analyzed. A method using the average reported caliber of the major intracranial vessels was applied to determine the aneurysm neck sizes on the diagnostic angiograms. The cases were divided into two groups according to neck size, 4 mm being the discriminative value for small and wide necks. The posttreatment angiogram of each case was analyzed to evaluate the degree of occlusion achieved by the technique. Necks were successfully measured in 95% of the aneurysms. Complete aneurysm thrombosis was observed in 85% of the small-necked aneurysms and in 15% of the wide-necked aneurysms. Accurate angiographic measurements of neck diameter can be obtained in most aneurysms. The size of an aneurysm neck correlates well with the results of the endovascular treatment. Small-necked aneurysms can be satisfactorily occluded with this technique. In wide-necked aneurysms this technique should be reserved for lesions having a high surgical risk. 10 refs., 1 fig., 1 tab.

  4. Emergent surgical embolectomy for middle cerebral artery occlusion due to carotid plaque rupture followed by elective carotid endarterectomy.

    PubMed

    Kiyofuji, Satoshi; Inoue, Tomohiro; Hasegawa, Hirotaka; Tamura, Akira; Saito, Isamu

    2014-09-01

    Embolic intracranial large artery occlusion with severe neurological deficit is associated with an extremely poor prognosis. The safest and most effective treatment strategy has not yet been determined when such emboli are associated with unstable proximal carotid plaque. The authors performed emergent surgical embolectomy for left middle cerebral artery (MCA) occlusion, and the patient experienced marked neurological recovery without focal deficit and regained premorbid activity. Postoperative investigation revealed "vulnerable plaque" of the left internal carotid artery without apparent evidence of cardiac embolism, such as would be seen with atrial fibrillation. Specimens from subsequent elective carotid endarterectomy (CEA) showed ruptured vulnerable plaque that was histologically consistent as a source of the intracranial embolic specimen. Surgical embolectomy for MCA occlusion due to carotid plaque rupture followed by CEA could be a safer and more effective alternative to endovascular treatment from the standpoint of obviating the risk of secondary embolism that could otherwise occur as a result of the manipulation of devices through an extremely unstable portion of plaque. Further, this strategy is associated with a high probability of complete recanalization with direct removal of hard and large, though fragile, emboli. PMID:24905562

  5. Photoactivation of lysosomally sequestered sunitinib after angiostatic treatment causes vascular occlusion and enhances tumor growth inhibition

    PubMed Central

    Nowak-Sliwinska, P; Weiss, A; van Beijnum, J R; Wong, T J; Kilarski, W W; Szewczyk, G; Verheul, H M W; Sarna, T; van den Bergh, H; Griffioen, A W

    2015-01-01

    The angiogenesis inhibitor sunitinib is a tyrosine kinase inhibitor that acts mainly on the VEGF and PDGF pathways. We have previously shown that sunitinib is sequestered in the lysosomes of exposed tumor and endothelial cells. This phenomenon is part of the drug-induced resistance observed in the clinic. Here, we demonstrate that when exposed to light, sequestered sunitinib causes immediate destruction of the lysosomes, resulting in the release of sunitinib and cell death. We hypothesized that this photoactivation of sunitinib could be used as a vaso-occlusive vascular-targeting approach to treating cancer. Spectral properties of sunitinib and its lysosomal accumulation were measured in vitro. The human A2780 ovarian carcinoma transplanted onto the chicken chorioallantoic membrane (CAM) and the Colo-26 colorectal carcinoma model in Balb/c mice were used to test the effects of administrating sunitinib and subsequently exposing tumor tissue to light. Tumors were subsequently resected and subject to immunohistochemical analysis. In A2780 ovarian carcinoma tumors, treatment with sunitinib+light resulted in immediate specific angio-occlusion, leading to a necrotic tumor mass 24 h after treatment. Tumor growth was inhibited by 70% as compared with the control group (**P<0.0001). Similar observations were made in the Colo-26 colorectal carcinoma, where light exposure of the sunitinib-treated mice inhibited tumor growth by 50% as compared with the control and by 25% as compared with sunitinib-only-treated tumors (N≥4; P=0.0002). Histology revealed that photoactivation of sunitinib resulted in a change in tumor vessel architecture. The current results suggest that the spectral properties of sunitinib can be exploited for application against certain cancer indications. PMID:25675301

  6. Unilateral horizontal semicircular canal occlusion induces serotonin increase in medial vestibular nuclei: a study using microdialysis in vivo coupled with HPLC-ECD.

    PubMed

    Zhang, Ke; Li, Qian; Xu, Jia; Liu, Junxiu; Ke, Jia; Kang, Wei; Li, Tao; Ma, Furong

    2015-06-01

    Unilateral single semicircular canal occlusion (USSCO) is an effective treatment for some cases of intractable vertigo. All patients suffer behavioural imbalance caused by surgery, and then recover with a resumption of vestibular function. However, the compensation mechanism has not been fully evaluated. Findings suggest that serotonin (5-HT) is released from nerve terminals, and plays a vital role in the plasticity of the central nervous system. In this study, we performed surgery of unilateral single semicircular canal occlusion (USSCO) on guinea pigs, and investigated the change of 5-HT by in vivo microdialysis of the medial vestibular nucleus (MVN) coupled with high-performance liquid chromatography and electrochemical detection (HPLC-ECD). A total of 12 guinea pigs were divided randomly into two groups, namely the USSCO group and the control group. Animals in the USSCO group underwent surgery of lateral horizontal semicircular canal occlusion, and those in the control group experienced the same operation but just to expose the horizontal semicircular canal without occlusion. Vestibular disturbance symptoms were observed in the case of the USSCO group, e.g. head tilting, and forced circular movements and spontaneous nystagmus at postoperative days 1 and 3. The basal level of 5-HT was determined to be 316.78 ± 16.62 nM. It elevated to 448.85 ± 24.56 nM at one day following occlusion (P = 0.001). The increase was completely abolished with the vestibular dysfunction recovery. The results showed that unilateral horizontal semicircular canal occlusion could increase the 5-HT level in MVN. 5-HT may play a significant role in the process of central vestibular compensation with residual vestibular function. PMID:25943376

  7. Endoscopic and Abdominal Management of Complete Benign Esophageal Obstruction

    PubMed Central

    2016-01-01

    Benign esophageal strictures leading to complete esophageal occlusion are well known. In the pre-endoscopic era, such cases required surgery, but over the last decade, various novel endoscopic techniques have been developed to prevent morbidity and mortality. A 37-year-old man presented after 1 year of dysphagia and weight loss, and was found to have complete esophageal obstruction, not allowing even passage of guidewire. We used a combination antegrade endoscopic abdominal procedures to deploy a stent, obviating the need for surgery. His symptoms improved dramatically, and the stent was successfully removed 12 weeks later. He is now swallowing normally and has gained significant weight. PMID:27144192

  8. Ultrastructural features of masseter muscle exhibiting altered occlusal relationship - a study in a rodent model

    SciTech Connect

    Lisboa, Marcio V.; Aciole, Gilberth T. S.; Oliveira, Susana C. P. S.; Marques, Aparecida M. C.; Pinheiro, Antonio L. B.; Santos, Jean N.; Baptista, Abrahao F.; Aguiar, Marcio C.

    2010-05-31

    The role of occlusion on Tempormandibular Disorders (TMD) is still unclear, mainly regarding muscular function. The aim of this study was to evaluate the occlusion highlights on masseter ultra morphology. Twenty Wistar rats were randomly divided in four groups: 10 for control group, 10 for occlusal alteration group (CCO). Rats underwent unilateral amputation of the left inferior and superior molar cusps to simulate an occlusal wear situation. The rats of control group had no occlusal wear. Half of the animals of each group was sacrificed in 14 days after the occlusal consuming and half 30 days after the occlusal consuming. The masseter muscles ipsilateral to the amputated molars were excised and processed for light microscopy, electron microscopy. The light microscopy did not show differences between the groups. The electron microscopy was able to detect a degree of intracellular damage in muscle fibers of CCO group: swollen mitochondria with disrupted cristae and cleared matrix, signs of hypercontraction of I bands and myofibril disorganization.

  9. Ultrastructural features of masseter muscle exhibiting altered occlusal relationship—a study in a rodent model

    NASA Astrophysics Data System (ADS)

    Lisboa, Marcio V.; Aciole, Gilberth T. S.; Oliveira, Susana C. P. S.; Marques, Aparecida M. C.; Baptista, Abrahão F.; Pinheiro, Antonio L. B.; Aguiar, Marcio C.; Santos, Jean N.

    2010-05-01

    The role of occlusion on Tempormandibular Disorders (TMD) is still unclear, mainly regarding muscular function. The aim of this study was to evaluate the occlusion highlights on masseter ultra morphology. Twenty Wistar rats were randomly divided in four groups: 10 for control group, 10 for occlusal alteration group (CCO). Rats underwent unilateral amputation of the left inferior and superior molar cusps to simulate an occlusal wear situation. The rats of control group had no occlusal wear. Half of the animals of each group was sacrificed in 14 days after the occlusal consuming and half 30 days after the occlusal consuming. The masseter muscles ipsilateral to the amputated molars were excised and processed for light microscopy, electron microscopy. The light microscopy did not show differences between the groups. The electron microscopy was able to detect a degree of intracellular damage in muscle fibers of CCO group: swollen mitochondria with disrupted cristae and cleared matrix, signs of hypercontraction of I bands and myofibril disorganization.

  10. The Role for Adjunctive Image in Pre-procedural Assessment and Peri-Procedural Management in Chronic Total Occlusion Recanalisation

    PubMed Central

    Estevez-Loureiro, Rodrigo; Ghione, Matteo; Kilickesmez, Kadriye; Agudo, Pilar; Lindsay, Alistair; Mario, Carlo Di

    2014-01-01

    Non invasive coronary angiography with multislice computed tomography has exquisite sensitivity to detect calcium and even the faintest late contrast filling of the distal vessel. Calcium burden and occlusion length are still valuable markers of duration, complexity and success of the recanalisation procedure. The ability to visualise the vessel also in the occluded segment, especially if calcified, can also help the operator to understand where to pierce the proximal cap in stumpless occlusions and to predict unusual courses, especially in very tortuous arteries. Imaging side by side CT images and angiography during the recanalisation procedure is an established practice in many active CTO laboratories and algorithms for co-registration are designed to overcome the challenges of systo-diastolic and respiratory motion. Intravascular ultrasound is used in almost all cases by the experienced Japanese CTO operators but most of the times its main use is a better identification of the diseased segment after predilatation to ensure complete stent cover and appropriate stent expansion, an application similar to other complex non occlusive lesions. The specificity of IVUS during CTO recanalisation is the identification of the vessel path in stumpless occlusions and the guidance of wire reentry especially during reverse Controlled Retrograde Anterograde Tracking. Optical coherence tomography has limitations in the setting of CTO recanalisation because of the need of forceful contrast flushing to clear blood, contraindicated in the presence of anterograde dissections, and the limited penetration. The variability in the use of both non-invasive and invasive imaging during CTO recanalisation is immense, going from more than 90% in Japan to less than 20% in Europe and intermediate penetration in the USA. Probably the explanation is almost only in availability and cost because all countries see a progressive increase of use suggesting that these methods are becoming an

  11. CENTRIFUGAL MEMBRANE FILTRATION

    SciTech Connect

    William A. Greene; Patricia A. Kirk; Richard Hayes; Joshua Riley

    2005-10-28

    SpinTek Membrane Systems, Inc., the developer of a centrifugal membrane filtration technology, has engineered and developed a system for use within the U.S. Department of Energy (DOE) Environmental Management (EM) Program. The technology uses supported microporous membranes rotating at high rpm, under pressure, to separate suspended and colloidal solids from liquid streams, yielding a solids-free permeate stream and a highly concentrated solids stream. This is a crosscutting technology that falls under the Efficient Separations and Processing Crosscutting Program, with potential application to tank wastes, contaminated groundwater, landfill leachate, and secondary liquid waste streams from other remediation processes, including decontamination and decommissioning systems. SpinTek II High Shear Rotary Membrane Filtration System is a unique compact crossflow membrane system that has large, demonstrable advantages in performance and cost compared to currently available systems: (1) High fluid shear prevents membrane fouling even with very high solids content; hazardous and radioactive components can be concentrated to the consistency of a pasty slurry without fouling. (2) Induced turbulence and shear across the membrane increases membrane flux by a factor of ten over existing systems and allows operation on fluids not otherwise treatable. (3) Innovative ceramic membrane and mechanical sealing technology eliminates compatibility problems with aggressive DOE waste streams. (4) System design allows rapid, simple disassembly for inspection or complete decontamination. (5) Produces colloidal- and suspended-solids-free filtrate without the addition of chemicals. The first phase of this project (PRDA maturity stage 5) completed the physical scale-up of the SpinTek unit and verified successful scale-up with surrogate materials. Given successful scale-up and DOE concurrence, the second phase of this project (PRDA maturity stage 6) will provide for the installation and

  12. Scuba diving, acute left anterior descending artery occlusion and normal ECG

    PubMed Central

    Doll, Sébastien Xavier; Rigamonti, Fabio; Roffi, Marco; Noble, Stéphane

    2013-01-01

    We report the case of an acute proximal occlusion of the left anterior descending coronary (LAD) artery following a scuba diving decompression accident and associated with normal ECG. Following uneventful thromboaspiration and coronary stenting, the patient was discharged on day  4 with secondary preventative therapies. A transthoracic echocardiography performed at this point showed a complete recovery compared with an initial localised akinesia involving the anterior and apical portion of the left ventricle upon admission. This case highlights that significant acute coronary lesions involving the LAD can occur without any ECG anomaly. The presence of acute and persistent angina associated with troponin elevation should prompt physicians to consider coronary angiography without delay, independently of the ECG results. PMID:23376677

  13. Central Retinal Vein Occlusion in a Patient with Retinal Vasculitis and Crohn's Disease

    PubMed Central

    Figueiredo, Lígia; Rothwell, Renata; Brandão, Arnaldo

    2014-01-01

    The authors report a rare case of a 47-year-old woman with Crohn's disease (CD) who presented with retinal vasculitis and central retinal vein occlusion (CRVO) during remission. The patient complained of sudden painless visual loss in her left eye (OS). Ophthalmologic evaluation revealed a best corrected visual acuity (BCVA) of 20/20 in the right eye and hand movements in OS. Ophthalmoscopy and fluorescein angiography of OS showed signs of nonischemic CRVO and extensive vasculitis. She was treated with oral prednisolone, mercaptopurine, and intravitreal bevacizumab in OS. After 1 month of treatment, VA of OS improved to 5/10 and after 1 year it was 10/10 with complete resolution of retinal vasculitis and nonischemic CRVO. PMID:25506451

  14. Successful endovascular treatment for high take off aorto-iliac occlusive disease.

    PubMed

    Nomura, Akihiro; Nagashima, Michio; Tomoi, Yusuke; Tosaka, Atsushi; Soga, Yoshimitsu

    2015-01-01

    A 73-year-old man with a history of intermittent claudication for the previous six years visited our hospital. His ankle-brachial index (ABI) was very low on both sides, and computed tomography (CT) indicated bilateral aorto-iliac occlusive disease (AIOD). As he refused to undergo open surgery, endovascular treatment (EVT) was administered. After the first and second EVT sessions, the intermittent claudication improved completely. In addition, the ABI normalized (right: 1.01, left: 0.99), and CT demonstrated full expansion of the stents. His post-EVT course was uneventful for 18 months. The use of EVT to treat AIOD is technically feasible and may serve as a potential treatment option for patients with an inoperable condition. PMID:25876573

  15. Crystalline Membranes

    NASA Technical Reports Server (NTRS)

    Tsapatsis, Michael (Inventor); Lai, Zhiping (Inventor)

    2008-01-01

    In certain aspects, the invention features methods for forming crystalline membranes (e.g., a membrane of a framework material, such as a zeolite) by inducing secondary growth in a layer of oriented seed crystals. The rate of growth of the seed crystals in the plane of the substrate is controlled to be comparable to the rate of growth out of the plane. As a result, a crystalline membrane can form a substantially continuous layer including grains of uniform crystallographic orientation that extend through the depth of the layer.

  16. Predictors and Periprocedural Myocardial Injury Rate of Small Side Branches Occlusion in Coronary Bifurcation Intervention

    PubMed Central

    Zhang, Dong; Xu, Bo; Yin, Dong; Li, Yiping; He, Yuan; You, Shijie; Qiao, Shubin; Wu, Yongjian; Yan, Hongbing; Yang, Yuejin; Gao, Runlin; Dou, Kefei

    2015-01-01

    Abstract Occlusion of small side branch (SB) may result in significant adverse clinical events. We aim to characterize the predictors of small SB occlusion and incidence of periprocedural myocardial injury (PMI) in coronary bifurcation intervention. Nine hundred twenty-five consecutive patients with 949 bifurcation lesions (SB ≤ 2.0 mm) treated with percutaneous coronary intervention (PCI) were studied. All clinical characteristics, coronary angiography findings, PCI procedural factors, and quantitative coronary angiographic analysis data were collected. SB occlusion after main vessel (MV) stenting was defined as no blood flow or any thrombolysis in myocardial infarction (TIMI) flow grade decrease in SB after MV stenting. Multivariate logistic regression analysis was performed to identify independent predictors of small SB occlusion. Creatine kinase-myocardial band activity was determined by using an immunoinhibition assay and confirmed by mass spectrometry. Incidence of PMI between no SB occlusion group and SB occlusion group was compared. SB occlusion occurred in 86 (9.1%) of 949 bifurcation lesions. Of SB occlusion, total occlusion occurred in 64 (74.4%) lesions and a decrease in TIMI flow occurred in 22 (25.6%) lesions. True bifurcation lesion, irregular plaque, predilation in SB, preprocedural SB TIMI flow grade, preprocedural diameter stenosis of distal MV, preprocedural diameter stenosis of bifurcation core, bifurcation angle, diameter ratio between MV and SB, diameter stenosis of SB before MV stenting, and MV lesion length were independent risk factors of SB occlusion. We observed a significantly higher incidence of PMI in each cutoff level in patients with SB occlusion compared with those without SB occlusion. True bifurcation lesion, irregular plaque, and 8 other predictors were independent predictors of SB occlusion. Patients with small SB occlusion had significant higher incidence of PMI. PMID:26107685

  17. Endobronchial occlusive disease: Nd:YAG or PDT?

    NASA Astrophysics Data System (ADS)

    Regal, Anne-Marie; Takita, Hiroshi

    1991-06-01

    Patients with endobronchial occlusion commonly experience dyspnea, cough, hemoptysis, pneumonitis, and atelectasis. If luminal patency is not re-established, obstructive symptoms may progress to sepsis and death. Although the overall survival of patients with lung cancer may not be altered by relief of airway obstruction, the prognosis for this subset of patients may be improved by eliminating the septic complications of bronchial occlusion. Techniques to treat occluded bronchi include electro-fulguration, cryotherapy, brachytherapy, laser (CO2, Nd-YAG) therapy, and photodynamic therapy (PDT). These represent local forms of treatment and are intended to be palliative. Nd-YAG and PDT are the modalities more frequently utilized in this setting. Comparison of the two treatment forms may furnish insight regarding the appropriate role for each as individual therapies and as part of the armamentarium of cancer therapies.

  18. Relation between retinal vein occlusions and axial length.

    PubMed Central

    Aritürk, N.; Oge, Y.; Erkan, D.; Süllü, Y.; Mohajerý, F.

    1996-01-01

    AIMS: To evaluate the ocular axial length as a risk factor for development of central retinal vein occlusion (CRVO) and branch retinal vein occlusion (BRVO). METHODS: Ocular axial lengths were measured, by A-scan ultrasonography, in 17 patients with CRVO and 41 patients with BRVO and compared with those of contralateral unaffected eyes and 66 age matched controls. RESULTS: In 17 patients with CRVO the mean axial length of affected eyes was 22.25 (SD 0.19) mm and of unaffected eyes was 22.61 (0.13) mm. In 41 patients with BRVO the mean axial length of affected eyes was 22.89 (0.11) mm and of unaffected eyes was 22.99 (0.12) mm. CONCLUSION: These findings confirm that the axial lengths in CRVO and BRVO were significantly shorter than in the controls. This significant difference may be a risk factor in the development of CRVO and BRVO. PMID:8795376

  19. Left Subclavian Artery Occlusion: Femoro-Axillary Artery Retrograde Bypass

    PubMed Central

    Nakashima, Masaya; Kobayashi, Hideaki; Kobayashi, Masayoshi

    2016-01-01

    The treatment tactics for subclavian artery occlusion include the more commonly used endovascular therapy rather than surgical intervention. We present a case of a 61-year-old woman with dialysis-dependent chronic renal failure who experienced left finger necrosis in the left upper extremity. To salvage the limb, we performed femoro-axillary (fem-ax) artery bypass using an autologous saphenous vein graft. However, 10 months later, she experienced coldness in the left forearm. Angiography revealed chronic total occlusion of the venous bypass. Despite emergent thrombectomy, redo fem-ax artery bypass operation was performed using a prosthetic graft. Upper limb salvage can be achieved by fem-ax artery retrograde bypass. PMID:27386454

  20. Occlusion-capable multiview volumetric three-dimensional display

    NASA Astrophysics Data System (ADS)

    Cossairt, Oliver S.; Napoli, Joshua; Hill, Samuel L.; Dorval, Rick K.; Favalora, Gregg E.

    2007-03-01

    Volumetric 3D displays are frequently purported to lack the ability to reconstruct scenes with viewer-position-dependent effects such as occlusion. To counter these claims, a swept-screen 198-view horizontal-parallax-only 3D display is reported here that is capable of viewer-position-dependent effects. A digital projector illuminates a rotating vertical diffuser with a series of multiperspective 768×768 pixel renderings of a 3D scene. Evidence of near-far object occlusion is reported. The aggregate virtual screen surface for a stationary observer is described, as are guidelines to construct a full-parallax system and the theoretical ability of the present system to project imagery outside of the volume swept by the screen.

  1. Ocular vascular occlusive disorders: Natural history of visual outcome☆

    PubMed Central

    Hayreh, Sohan Singh

    2014-01-01

    Ocular vascular occlusive disorders collectively constitute the most common cause of visual disability. Before a disease can be managed, it is essential to understand its natural history, so as to be able to assess the likely effectiveness of any intervention. I investigated natural history of visual outcome in prospective studies of 386 eyes with non-arteritic anterior ischemic optic neuropathy (NA-AION), 16 eyes with non-arteritic posterior ischemic optic neuropathy, 697 eyes with central retinal vein occlusion (CRVO), 67 eyes with hemi-CRVO (HCRVO), 216 eyes with branch retinal vein occlusion (BRVO), 260 eyes with central retinal artery occlusion (CRAO), 151 eyes with branch retinal artery occlusion (BRAO) and 61 eyes with cilioretinal artery occlusion (CLRAO). My studies have shown that every one of these disorders consists of multiple distinct clinical sub-categories with different visual findings. When an ocular vascular occlusive disorder is caused by giant cell arteritis, which is an ophthalmic emergency, it would be unethical to do a natural history study of visual outcome in them, because in this case early diagnosis and immediate, intensive high-dose steroid therapy is essential to prevent any further visual loss, not only in the involved eye but also in the fellow, normal eye. In NA-AION in eyes seen ≤2 weeks after the onset, visual acuity (VA) improved in 41% of those with VA 20/70 or worse, and visual field (VF) improved in 26% of those with moderate to severe VF defect. In non-ischemic CRVO eyes with VA 20/70 or worse, VA improved in 47% and in ischemic CRVO in 23%; moderate to severe VF defect improved in 79% in non-ischemic CRVO and in 27% in ischemic CRVO. In HCRVO, overall findings demonstrated that initial VA and VF defect and the final visual outcome were different in non-ischemic from ischemic HCRVO – much better in the former than the latter. In major BRVO, in eyes with initial VA of 20/70 or worse, VA improved in 69%, and moderate to

  2. Recognition of Simple 3D Geometrical Objects under Partial Occlusion

    NASA Astrophysics Data System (ADS)

    Barchunova, Alexandra; Sommer, Gerald

    In this paper we present a novel procedure for contour-based recognition of partially occluded three-dimensional objects. In our approach we use images of real and rendered objects whose contours have been deformed by a restricted change of the viewpoint. The preparatory part consists of contour extraction, preprocessing, local structure analysis and feature extraction. The main part deals with an extended construction and functionality of the classifier ensemble Adaptive Occlusion Classifier (AOC). It relies on a hierarchical fragmenting algorithm to perform a local structure analysis which is essential when dealing with occlusions. In the experimental part of this paper we present classification results for five classes of simple geometrical figures: prism, cylinder, half cylinder, a cube, and a bridge. We compare classification results for three classical feature extractors: Fourier descriptors, pseudo Zernike and Zernike moments.

  3. Facial height in Japanese-Brazilian descendants with normal occlusion

    PubMed Central

    Vieira, Fabiano Paiva; Pinzan, Arnaldo; Janson, Guilherme; Fernandes, Thais Maria Freire; Sathler, Renata Carvalho; Henriques, Rafael Pinelli

    2014-01-01

    OBJECTIVE: The aim of this study was to determine the standards of facial height in 30 young (14-year-old) Japanese-Brazilian descendants with normal occlusion, and assess whether sexual dimorphism is evident. METHODS: The cephalometric measurements used followed the analyses by Wylie-Johnson, Siriwat-Jarabak, Gebeck, Merrifield and Horn. RESULTS: Results showed dimorphism for total anterior facial height (TAFH), lower anterior facial height (LAFH), anterior facial height (AFH), total posterior facial height (TPFH) and upper posterior facial height (UPFH) measurements. CONCLUSIONS: The standards of facial heights in young Japanese-Brazilian descendants with normal occlusion were observed. Sexual dimorphism was identified in five out of thirteen evaluated variables at this age range. PMID:25715717

  4. Dental Occlusion among School Going Children of Maharashtra

    PubMed Central

    Kumar, Mukesh; Banerjee, Prasenjit; Gondhalekar, Rajesh; Gondhalekar, Rajeshri; Lall, Rajeev; Parwani, Rajkumar

    2014-01-01

    Background: A dental survey was conducted among the school going children of age group 6-13 yrs, focused to find out incidence of malocclusion so as to predict the probable time at which preventive measures can be taken. Materials and Methods: A survey was carried on 985 unrelated healthy subject, including of 575 boys and 410 girls and the population was divided into three economic group of upper, middle and lower class. Results: 1)In the study 57% of sample is found with normal occlusion.2)The proportion of malocclusion was higher in males.3)Lower income group sample showed highest proportion of malocclusion. Conclusion: In this study on school going children, it was found out that 57% of population showed normal occlusion and that malocclusion was higher in males and in lower income group population. PMID:25214733

  5. Internal carotid pseudo-occlusion: early and late results.

    PubMed

    Pulli, R; Frosini, P; Gatti, M; Narcetti, S; Bernacchi, R; Pratesi, C

    1997-02-01

    Internal carotid pseudo-occlusion (ICP) is a pathology of difficult diagnostic evaluation and treatment in the group of extracranial carotid diseases. The authors report the results of 24 ICP(S) surgically treated in the last five years. No perioperative death was reported. The neurological morbility rate was as low as 4% (1/24), which is quite a good results for this high-risk pathology. Clinical and instrumental follow-up was performed (at 1-3-6-12-24 months from surgery). Six early asymptomatic thromboses (25%) were observed, and the remaining patients showed patent vessels and no symptoms at all. In conclusion surgical treatment of ICP is often able to prevent cerebral ischaemia, and the high rate of early occlusion should not limit surgical indication. PMID:9128116

  6. Paraplegia due to Acute Aortic Coarctation and Occlusion

    PubMed Central

    Park, Chang-Bum; Kim, Min-Ki; Kim, Sang-Hyun

    2014-01-01

    Coarctation and occlusion of the aorta is a rare condition that typically presents with hypertension or cardiac failure. However, neuropathy or myelopathy may be the presenting features of the condition when an intraspinal subarachnoid hemorrhage has compressed the spinal cord causing ischemia. We report two cases of middle-aged males who developed acute non-traumatic paraplegia. Undiagnosed congenital abnormalities, such as aortic coarctation and occlusion, should be considered for patients presenting with nontraumatic paraplegia in the absence of other identifiable causes. Our cases suggest that spinal cord ischemia resulting from acute spinal subarachnoid hemorrhage and can cause paraplegia, and that clinicians must carefully examine patients presenting with nontraumatic paraplegia because misdiagnosis can delay initiation of the appropriate treatment. PMID:24851152

  7. Uterine Artery Embolization Versus Laparoscopic Uterine Artery Occlusion: The Outcomes of a Prospective, Nonrandomized Clinical Trial

    SciTech Connect

    Mara, Michal; Kubinova, Kristyna; Maskova, Jana; Horak, Petr; Belsan, Tomas; Kuzel, David

    2012-10-15

    Purpose: To compare outcomes of two different types of occlusive therapy of uterine fibroids. Methods: Women with fibroid(s) unsuitable for laparoscopic myomectomy (LM) were treated with uterine artery embolization (UAE) or laparoscopic uterine artery occlusion (LUAO). Results: Before the procedure, patients treated with UAE (n = 100) had a dominant fibroid greater in size (68 vs. 48 mm) and a mean age lower (33.1 vs. 34.9 years) than surgically treated patients (n = 100). After 6 months, mean shrinkage of fibroid volume was 53 % after UAE and 39 % after LUAO (p = 0.063); 82 % of women after UAE, but only 23 % after LUAO, had complete myoma infarction (p = 0.001). Women treated with UAE had more complications (31 vs. 11 cases, p = 0.006) and greater incidence of hysteroscopically verified intrauterine necrosis (31 vs. 3 %, p = 0.001). Both groups were comparable in markers of ovarian functions and number of nonelective reinterventions. The groups did not differ in pregnancy (69 % after UAE vs. 67 % after LUAO), delivery (50 vs. 46 %), or abortion (34 vs. 33 %) rates. The mean birth weight of neonates was greater (3270 vs. 2768 g, p = 0.013) and the incidence of intrauterine growth restriction lower (13 vs. 38 %, p = 0.046) in post-UAE patients. Conclusion: Both methods are effective in the treatment of women with future reproductive plans and fibroids not suitable for LM. UAE is more effective in causing complete ischemia of fibroids, but it is associated with greater risk of intrauterine necrosis. Both methods have low rate of serious complications (except for a high abortion rate).

  8. TRANSITION TO COLLATERAL FLOW AFTER ARTERIAL OCCLUSION PREDISPOSES TO CEREBRAL VENOUS STEAL

    PubMed Central

    Pranevicius, Osvaldas; Pranevicius, Mindaugas; Pranevicius, Henrikas; Liebeskind, David S.

    2011-01-01

    Introduction Stroke related tissue pressure increase in the core (Pcore) and penumbra (Ppen) determines regional cerebral perfusion pressure (rCPP) defined as a difference between local inflow pressure (Pi) and venous (Pv) or tissue pressure, whichever is higher. We previously showed that venous pressure reduction below the Pcore causes blood flow diversion - cerebral venous steal. Now we investigated how transition to collateral circulation after complete arterial occlusion affects rCPP distribution. Methods We modified two parallel Starling resistor model to simulate transition to collateral inflow after complete main stem occlusion. We decreased Pv from the arterial pressure (Pa) to zero, and investigated how arterial and venous pressure elevation augments rCPP. Results When core pressure exceeded venous (Pcore>Pv), rCPP=Pi−Pcore. Venous pressure (Pv) decrease from Pa to Pcore caused smaller Pi to drop augmenting rCPP. Further drop of Pv to Ppen decreased rCPP in the core but augmented rCPP in penumbra. After transition to collateral circulation, lowering Pv below Ppen further decreased rCPP and collaterals themselves became pathway for steal. Venous pressure level at which rCPP in the core becomes zero we termed the “point of no reflow” (PONR). Transition from direct to collateral circulation resulted in decreased Pi, decreased rCPP, and a shift of PONR to higher venous loading values. Arterial pressure augmentation increased rCPP, but only after venous pressure exceeded PONR. Conclusion In the presence of tissue pressure gradients, transition to collateral flow predisposes to venous steal (collateral failure) which may be reversed by venous pressure augmentation. PMID:22246692

  9. Digital subtraction angiography in pediatric cerebrovascular occlusive disease

    SciTech Connect

    Faerber, E.N.; Griska, L.A.B.; Swartz, J.D.; Capitanio, M.A.; Popky, G.L.

    1984-08-01

    While conventional angiography has been used to demonstrate cerebrovascular occlusive disease in the past, digital subtraction angiography (DSA) is capable of showing progressive vascular involvement with ease, simplicity, and extremely low morbidity, making it particularly well suited for children and outpatients either alone or coordinated with computed tomography. The authors discuss the usefulness and advantages of DSA as demonstrated in 7 infants and children with hemiplegia, 4 of whom had sickle-cell disease.

  10. Deaths from Occlusive Arterial Disease in Renal Allograft Recipients

    PubMed Central

    Ibels, L. S.; Stewart, J. H.; Mahony, J. F.; Sheil, A. G. R.

    1974-01-01

    In a series of 325 recipients of cadaveric renal transplants sudden occlusive arterial disease was found to be responsible for 12% of deaths. Acute myocardial infarction (9%) occurred 25 times more than expected in the normal population and cerebral thrombosis (3%) 300 times more. The greatest loss was in the initial three-month period after transplantation. Patients with renal failure due to essential hypertension were especially at risk, accounting for six of the 12 deaths. PMID:4606408

  11. Secondary syphilis presenting with aortitis and coronary ostial occlusion.

    PubMed

    Chadwick, John A; MacNab, Anita; Sarma, Jaydeep; Ray, Simon; Kadir, Isaac; Muldoon, Eavan G

    2016-03-01

    Aortitis is an established manifestation of tertiary syphilis. We report a rare case of aortitis with ostial occlusion and left ventricular failure in secondary syphilis. Her management required a true multidisciplinary approach from multiple specialities due to complications of concomitant psychosis and a history of anaphylaxis to penicillin. This case illustrates the complexities of diagnosing and managing a rare presentation of this increasingly prevalent infection. PMID:26670911

  12. Oxygen Transport Ceramic Membranes

    SciTech Connect

    S. Bandopadhyay; T. Nithyanantham; X.-D Zhou; Y-W. Sin; H.U. Anderson; Alan Jacobson; C.A. Mims

    2005-11-01

    The present quarterly report describes some of the investigations on the structural properties of dense OTM bars provided by Praxair and studies on newer composition of Ti doped LSF. In the current research, the electrical conductivity and Seebeck coefficient were measured as a function of temperature in air. Based on these measurements, the charge carrier concentration, net acceptor dopant concentration, activation energy of conduction and mobility were estimated. The studies on the fracture toughness of the LSFT and dual phase membranes at room temperature have been completed and reported previously. The membranes that are exposed to high temperatures at an inert and a reactive atmosphere undergo many structural and chemical changes which affects the mechanical properties. To study the effect of temperature on the membranes when exposed to an inert environment, the membranes (LAFT and Dual phase) were heat treated at 1000 C in air and N{sub 2} atmosphere and hardness and fracture toughness of the membranes were studied after the treatment. The indentation method was used to find the fracture toughness and the effect of the heat treatment on the mechanical properties of the membranes. Further results on the investigation of the origin of the slow kinetics on reduction of ferrites have been obtained. The slow kinetics appears to be related to a non-equilibrium reduction pathway that initially results in the formation of iron particles. At long times, equilibrium can be reestablished with recovery of the perovskite phase. 2-D modeling of oxygen movement has been undertaken in order to fit isotope data. The model will serve to study ''frozen'' profiles in patterned or composite membranes.

  13. Membrane Transport Phenomena (MTP)

    NASA Technical Reports Server (NTRS)

    Mason, Larry W.

    1997-01-01

    The third semi-annual period of the MTP project has been involved with performing experiments using the Membrane Transport Apparatus (MTA), development of analysis techniques for the experiment results, analytical modeling of the osmotic transport phenomena, and completion of a DC-9 microgravity flight to test candidate fluid cell geometries. Preparations were also made for the MTP Science Concept Review (SCR), held on 13 June 1997 at Lockheed Martin Astronautics in Denver. These activities are detailed in the report.

  14. Biological membranes

    PubMed Central

    Watson, Helen

    2015-01-01

    Biological membranes allow life as we know it to exist. They form cells and enable separation between the inside and outside of an organism, controlling by means of their selective permeability which substances enter and leave. By allowing gradients of ions to be created across them, membranes also enable living organisms to generate energy. In addition, they control the flow of messages between cells by sending, receiving and processing information in the form of chemical and electrical signals. This essay summarizes the structure and function of membranes and the proteins within them, and describes their role in trafficking and transport, and their involvement in health and disease. Techniques for studying membranes are also discussed. PMID:26504250

  15. Membranous nephropathy

    MedlinePlus

    ... to reduce cholesterol and triglyceride levels (most often statins) may be recommended. A low-salt diet may ... of membranous nephropathy Your symptoms get worse or don't go away You develop new symptoms You have ...

  16. Retinal vein occlusions: a review for the internist.

    PubMed

    Marcucci, Rossella; Sofi, Francesco; Grifoni, Elisa; Sodi, Andrea; Prisco, Domenico

    2011-08-01

    Retinal vein occlusion (RVO) is a disease that is often associated with a variety of systemic disorders including arterial hypertension, diabetes mellitus, dyslipidemia and systemic vasculitis. There are various types of RVO, categorized on the basis of the site of occlusion and on the type of consequent vascular damage. Central retinal vein occlusion (CRVO) is the most clinically relevant type of RVO. In addition to well-known classical risk factors, new thrombophilic factors have been investigated in patients with RVO. Data concerning a number of the parameters remain contradictory; yet, hyperhomocysteinemia and vitamins involved in methionine metabolism appear to play a significant role in the pathogenesis of this disease. Alterations in the fibrinolysis pathway (elevated levels of PAI-1 and Lipoprotein (a)), together with haemorheologic modifications have been recently consistently associated with the disease. Medical treatment includes identification and correction of vascular risk factors. In addition, LMWHs appear to be the best therapeutic approach even if based on a limited number of trials, conducted on a limited number of patients. No data are available on the possible role of antithrombotic strategies in the long-term prevention of recurrent RVO or vascular events. PMID:21547483

  17. Blur and the perception of depth at occlusions.

    PubMed

    Zannoli, Marina; Love, Gordon D; Narain, Rahul; Banks, Martin S

    2016-01-01

    The depth ordering of two surfaces, one occluding the other, can in principle be determined from the correlation between the occlusion border's blur and the blur of the two surfaces. If the border is blurred, the blurrier surface is nearer; if the border is sharp, the sharper surface is nearer. Previous research has found that observers do not use this informative cue. We reexamined this finding. Using a multiplane display, we confirmed the previous finding: Our observers did not accurately judge depth order when the blur was rendered and the stimulus presented on one plane. We then presented the same simulated scenes on multiple planes, each at a different focal distance, so the blur was created by the optics of the eye. Performance was now much better, which shows that depth order can be reliably determined from blur information but only when the optical effects are similar to those in natural viewing. We asked what the critical differences were in the single- and multiplane cases. We found that chromatic aberration provides useful information but accommodative microfluctuations do not. In addition, we examined how image formation is affected by occlusions and observed some interesting phenomena that allow the eye to see around and through occluding objects and may allow observers to estimate depth in da Vinci stereopsis, where one eye's view is blocked. Finally, we evaluated how accurately different rendering and displaying techniques reproduce the retinal images that occur in real occlusions. We discuss implications for computer graphics. PMID:27115522

  18. Near-IR imaging of occlusal dental decay

    NASA Astrophysics Data System (ADS)

    Buehler, Christopher M.; Fried, Daniel

    2005-03-01

    Dental enamel manifests high transparency in the near-IR. Previous work demonstrated that near-IR light at 1310-nm is ideally suited for the transillumination of interproximal dental caries (dental decay in between teeth) [1]. However, most new dental decay occurs in the pits and fissures of the occlusal (biting) surfaces of posterior teeth. These caries lesions cannot be detected by x-rays during the early stages of decay due to the overlapping topography of the crown of the tooth. In this study, a near-IR imaging system operating at 1310-nm was used to acquire occlusal images by launching the near-IR light into the buccal surface of the tooth just above the gingival margin (gum-line). The near-IR light diffuses through the highly scattering dentin providing uniform back illumination of the enamel of the crowns allowing imaging of the occlusal surfaces. The near-IR images show high contrast between sound and demineralized areas. Demineralization (decay) can be easily differentiated from stains and pigmentation. Moreover, the high transparency of the enamel enables imaging at greater depth for the detection of subsurface decay hidden under the enamel. These early images suggest that the near-IR offers significant advantages over conventional visual, tactile and radiographic caries detection methods.

  19. A Novel Canine Model of Acute Vertebral Artery Occlusion

    PubMed Central

    Zhang, Yunfeng; Jin, Min; Du, Bin; Lin, Hao; Xu, Chengyong; Jiang, Weijian; Jia, Jianping

    2015-01-01

    Background The extended time window and theoretic reduction in hemorrhage make mechanical strategies an attractive approach for the treatment of patients with ischemic stroke. However, a limited availability of suitable animal models of cerebrovascular thrombosis has hampered the study of novel endovascular interventions. The aim of the present study was to develop a new technique for site-specific placement of a thrombus in a canine model that would allow for the evaluation of mechanical thrombectomy and clot retrieval methods and the visualization of thrombus dislocation or fragmentation during angiographic manipulation. Methods Angiography and embolization with a preformed thrombus were performed in 12 canines. Under fluoroscopic guidance, an embolism protection device (EPD) was anchored to the middle segment of the left vertebral artery (VA) via the left femoral arterial sheath. A preformed radiopaque clot was injected through the guide catheter into the left VA, via the contralateral femoral artery, proximal to the EPD. After 15 min of occlusion, the EPD was removed and persistent occlusion of the VA was documented angiographically. Results Angiography performed during the observation period confirmed the persistence of VA occlusion in each case, and displacement of the radiopaque clots did not occur during the 3-hour observation period. The technique allowed selective embolization of targeted vessels without thrombus fragmentation. Conclusion This study demonstrates, for the first time, a canine model of post-circulation embolism induced by autologous blood clot placement. This model can be rapidly formed and easily operated, and the site of thrombosis can be readily controlled. PMID:26545253

  20. Laparoscopic uterine artery occlusion combined with myomectomy for uterine myomas.

    PubMed

    Cheng, Zhongping; Yang, Weihong; Dai, Hong; Hu, Liping; Qu, Xiaoyan; Kang, Le

    2008-01-01

    We sought to evaluate the clinical feasibility and mid- to long-term effects of laparoscopic uterine artery occlusion before myomectomy in the treatment of uterine myomas. A total of 566 patients with uterine myoma were treated by laparoscopic uterine artery occlusion before myomectomy from October 2001 through July 2007. Mean blood loss was 88.2 +/- 52.7 mL (95% CI 82.7-93.8). The highest postoperative temperature was 37.8 +/- 0.3 degrees C, and the postoperative morbidity was 5.7% (32/566). Number of days to the return of bowel movement was 1.9 +/- 0.5d and in hospital stay after surgery was 7.7 +/- 2.5d. Complications included 2 instances of subcutaneous emphysema, 1 of vaginal bleeding, and 3 of mild intestinal obstruction. At a median of 26.3 months (range 6-69 months) of follow-up, the rate of myoma recurrence was 3.0% (15/517), uterus volume reduction was 48.9%, and correction of menstruation abnormality was 97.1% (502/517). Laparoscopic uterine artery occlusion before myomectomy can expand myomectomy indications with better results. PMID:18439509

  1. NONICHEMIC CENTRAL RETINAL VEIN OCCLUSION ASSOCIATED WITH HEREDITARY THROMBOPHYLIA.

    PubMed

    Fişuş, Andreea Dana; Pop, Doina Suzana; Rusu, Monica Blanka; Vultur, Florina; Horvath, Karin Ursula

    2015-01-01

    Retinal vein occlusion (RVO) is the second most common retinal vein disease with significant visual loss via thrombus or compression of vein wall. Thrombophilia is the predisposition to vascular thrombosis with the existence of genetic defect that leads to blood hypercoagulability. This report describes the case of a 55 year old male patient, with an active life who presented himself at the emergency room with acute visual lose, insidious and progressive visual field constriction, without any known history of neurological or vascular diseases. The examinations revealed unilateral optic nerve head edema, the fluorescein angiography was specific for nonischemic central retinal vein occlusion CRVO complicated with macular edema. Blood examinations has emphasized the presence of the heterozygous mutation A1298C in the methylenetetrahydrofolate reductase gene (MTHFR), the only one presented from the thrombophilia screen panel and a slightly elevated cholesterol level. During the follow-up period, the patient received anti-VEGF treatment (Bevacizumab, 3x 0.1 ml intravitreal injections) with improved visual acuity and amendment of macular edema. The complex etiology calls for interdisciplinary approach to determine better the cause of this ophthalmological disease. Although studies have found a correlation between some thrombophilia mutations and retinal vein occlusion, more studies that contain a larger number of patients are necessary in order to determine the final role of these gene variants. PMID:26978887

  2. The usefulness of a perfusion balloon in a case of late stent thrombosis that caused simultaneous double vessel occlusion.

    PubMed

    Nakabayashi, Keisuke; Okada, Hisayuki; Asano, Ryotaro; Nakazawa, Naomi; Nomura, Hidekimi; Oka, Toshiaki

    2016-07-01

    Simultaneous stent thrombosis in different coronary arteries requires rapid management. A 70-year-old man experienced simultaneous stent thrombosis at the left anterior descending and circumflex arteries. We used a perfusion balloon to prevent thrombus production at the left anterior descending artery, and completed percutaneous coronary intervention at the left circumflex artery in 10 min. The perfusion balloon was dilated during the procedure. In both vessels, Thrombolysis in myocardial infarction flow grade 3 was achieved after balloon deflation. Thus, use of a perfusion balloon for simultaneous double vessel occlusion helped avoid the need for redundant stent placement and shortened the procedure time. PMID:25971225

  3. Transcatheter closure of membranous ventricular septal defects with a new nitinol prosthesis in a natural swine model.

    PubMed

    Gu, X; Han, Y M; Titus, J L; Amin, Z; Berry, J M; Kong, H; Rickers, C; Urness, M; Bass, J L

    2000-08-01

    Transcatheter closure of a membranous ventricular septal defect (MVSD) is much more difficult than closure of other intracardiac defects because of the proximity to the aortic and tricuspid valves and their relatively large size in small children. In this report, transcatheter closure of naturally occurring membranous VSDs was attempted in 12 Yucatan minipigs. The prosthesis is constructed from fine Nitinol wires in the shape of two buttons and a connecting waist filled with polyester fiber. Two kinds of prosthesis were used in this study: concentric and eccentric left-sided retention disks. A 6 or 7 Fr delivery sheath was advanced across the membranous VSD over a wire from femoral vein. The prosthesis was inserted through the sheath by pushing the delivery cable to deploy a button into left ventricle and the second button was then deployed into right ventricle by withdrawing the sheath. Successful implantation of the device was achieved in all animals except one. Complete closure rate was 58.3% immediately after placement, 100% at 1 week, 90.9% at 1 month and 3 months, and 100% at 6 months. An associated aneurysm of the membranous septum increased significantly in size in two of three animals using the concentric device, and in none of the animals using the eccentric device. A trace to mild aortic regurgitation was present in two of the three animals using the concentric device, and only in one of the eight animals using the eccentric device. Five animals developed a trace to mild tricuspid regurgitation. Pathologic examination showed all devices to be covered by smooth neoendothelium at 3 months. This report presents the first experimental study where closure of membranous ventricular septal defects in a swine model was attempted by specially constructed devices. Procedural success and occlusion rates are very encouraging but overall results cannot equal surgery. Further experimentation is needed with devices that are redesigned according to the experience gained

  4. The effectiveness of a mouth guard to protect against strong occlusion caused by modified electroconvulsive therapy.

    PubMed

    Ogami, Saori; Yamada, Morimasa; Kanazawa, Mayuko; Takeda, Kiyoshi; Kimura, Naoaki; Mizutani, Hideki; Kohase, Hikaru; Fukayama, Haruhisa

    2014-10-01

    Modified electroconvulsive therapy (m-ECT) is a treatment for mental disease such as depressive disorder. Although a muscle relaxant is used during current application, strong occlusion occurs due to the proximity of the electrode to the temporal and masseter muscles. Although a feedback mechanism to avoid excessive occlusion occurs unconsciously, the mechanism does not work under general anesthesia. Strong occlusion may cause complications such as tooth injury, pain of the jaw, lip laceration, and bleeding of the gums. Although there was a report that the insertion of shock-absorbing materials such as gauze reduces complications, there has been no study on the effectiveness of a mouth guard (MG) for alleviating the occlusal force during m-ECT. The present study investigated the effectiveness of MG for alleviation of the occlusal force and complications during m-ECT. An ethyl-vinyl-acetate (EVA) MG was used as a shock absorbing material to mitigate the strong occlusion during m-ECT to investigate the influence of MG on the occlusal force and its effectiveness. The results showed that the occlusal force was alleviated by 58 ± 22% on average using MG during m-ECT. It also helped reduce intra-oral problems such as pain and bleeding. The results suggest the effectiveness of MG for alleviating the occlusal force during m-ECT and avoiding complications due to strong occlusion. PMID:25364808

  5. Strategies for Successful Percutaneous Revascularization of Chronic Total Occlusion of the Femoropopliteal Arteries When the Antegrade Passage of a Guide Wire Fails

    PubMed Central

    Lee, Hui Jin; Chang, Il Soo; Jeon, Hae Jeong; Park, Jeong Hee

    2012-01-01

    Objective To evaluate the efficacy of various strategies for revascularization of chronic total occlusion of femoropopliteal arteries when the guide wire does not pass in an anterograde direction. Materials and Methods Twenty-four patients with totally occluded femoropopliteal arteries (mean occlusion length 13.75 cm; range, 6-22 cm) were treated by using a retrograde approach and two novel catheters. After successful recanalization or reentry, balloon angioplasty followed by stent placement was performed to complete the revascularization. Results In 16 cases in which to cross the occlusion via intraluminal or subintimal route was failed, we used Frontrunner catheters in five cases and Outback catheters in 11 cases. In eight cases in which to reenter after subintimal passage of the guide wire was failed, we used Outback catheters. Successful recanalization was achieved intraluminally or subintimally in all cases. One perforation occurred during subintimal passage of the guide wire that was controlled by recanalization of another subintimal tract. There were no cases of distal thromboembolism or other complications. Conclusion A retrograde approach and using the Frontrunner and Outback catheters are safe and effective for successful revascularization of chronic total occlusion of femoropopliteal arteries. In particular, they are useful when the initial antegrade attempts at recanalization have failed. PMID:22778569

  6. A cephalometric evaluation of tongue from the rest position to centric occlusion in the subjects with class II division 1 malocclusion and class I normal occlusion

    PubMed Central

    Verma, Sanjeev K.; Tandon, Pradeep; Agrawal, D. K.; Prabhat, K. C.

    2012-01-01

    Background: One of the common types of oro-dental morphopathologic relationship is the Class II Division 1 malocclusion. Therefore, the study of tongue position in Class II Division 1 may reveal a role of the tongue in the etiology or diagnosis of malocclusion. Aims: Present study was done with the aim to evaluate the tongue position radiographically in centric occlusion and rest position in the subjects with Angle's Class 1 normal occlusion and subjects with Angle's Class II Division 1 malocclusion and to find out any differences in tongue position between Angle's Class 1 normal occlusion and Angle's Class II Division 1 malocclusion group. Materials and Methods: The present study was conducted on lateral cephalogram of 40 subjects between the age ranges of 16 to 22 years. The samples were divided into the Angle's Class 1 normal occlusion group (Group I) and the Angle's Class II Division 1 malocclusion group (Group II) with the 20 in each groups. The study involved the evaluation of tongue position at rest position and centric occlusion on the lateral head cephalogram. Results: This study for the evaluation of the tongue position from the rest position to the centric occlusion showed no statistically significant changes in both groups. However, there were greater changes in various parameters (From the rest position to the centric occlusion) in the subjects with Angle's Class II Division 1 malocclusion as compared to the subjects with the Angle's Class I normal occlusion group. Conclusion: From the present study following conclusion can be drawn: with the closure of mandible from the rest position to centric occlusion the tongue moved antero-superiorly in the tip region, superiorly in the dorsum region, and antero-superiorly in the posterior region in normal occlusion and postero-superiorly in Class II Division 1 malocclusion. PMID:24987623

  7. Amodal Completion in Bonobos

    ERIC Educational Resources Information Center

    Nagasaka, Yasuo; Brooks, Daniel I.; Wasserman, Edward A.

    2010-01-01

    We trained two bonobos to discriminate among occluded, complete, and incomplete stimuli. The occluded stimulus comprised a pair of colored shapes, one of which appeared to occlude the other. The complete and incomplete stimuli involved the single shape that appeared to have been partially covered in the occluded stimulus; the complete stimulus…

  8. Finite Element Analysis of Bone Stress for Miniscrew Implant Proximal to Root Under Occlusal Force and Implant Loading.

    PubMed

    Shan, Li-Hua; Guo, Na; Zhou, Guan-jun; Qie, Hui; Li, Chen-Xi; Lu, Lin

    2015-10-01

    Because of the narrow interradicular spaces and varying oral anatomies of individual patients, there is a very high risk of root proximity during the mini implants inserting. The authors hypothesized that normal occlusal loading and implant loading affected the stability of miniscrew implants placed in proximity or contact with the adjacent root. The authors implemented finite element analysis (FEA) to examine the effectiveness of root proximity and root contact. Stress distribution in the bone was assessed at different degrees of root proximity by generating 4 finite element models: the implant touches the root surface, the implant was embedded in the periodontal membrane, the implant touches the periodontal surface, and the implant touches nothing. Finite element analysis was then carried out with simulations of 2 loading conditions for each model: condition A, involving only tooth loading and condition B, involving both tooth and implant loading. Under loading condition A, the maximum stress on the bone for the implant touching the root was the distinctly higher than that for the other models. For loading condition B, peak stress areas for the implant touching the root were the area around the neck of the mini implant and the point of the mini implant touches the root. The results of this study suggest that normal occlusal loading and implant loading contribute to the instability of the mini implant when the mini implant touches the root. PMID:26207429

  9. In vivo near-IR imaging of occlusal lesions at 1310 nm

    NASA Astrophysics Data System (ADS)

    Fried, Daniel; Staninec, Michal; Darling, Cynthia L.; Lee, Chulsung; Kang, Hobin; Chan, Kenneth H.

    2011-03-01

    Several in vitro studies have demonstrated the potential for transillumination imaging and optical coherence tomography operating at 1310-nm for imaging caries lesions on tooth proximal and occlusal surfaces. Recently, we demonstrated that lesions on proximal surfaces could be imaged in vivo using NIR transillumination and that PS-OCT can be used in vivo to measure early demineralization on tooth buccal and occlusal surfaces. In this paper we report the first in vivo measurements using OCT and NIR imaging of occlusal lesions that have been scheduled for restoration. Occlusal lesions were chosen that were scheduled for restoration based on conventional diagnosis that consists of visual and tactile examination. Occlusal lesions were visible in the NIR. OCT looks promising for confirming the lateral spread of occlusal caries under the dentinal-enamel junction adjacent to fissures. These studies suggest that both near infrared transillumination imaging at 1310-nm and OCT provide valuable information about the severity of caries lesions.

  10. Direct estimation of nonrigid registrations with image-based self-occlusion reasoning.

    PubMed

    Gay-Bellile, Vincent; Bartoli, Adrien; Sayd, Patrick

    2010-01-01

    The registration problem for images of a deforming surface has been well studied. External occlusions are usually well handled. In 2D image-based registration, self-occlusions are more challenging. Consequently, the surface is usually assumed to be only slightly self-occluding. This paper is about image-based nonrigid registration with self-occlusion reasoning. A specific framework explicitly modeling self-occlusions is proposed. It is combined with an intensity-based, "direct" data term for registration. Self-occlusions are detected as shrinkage areas in the 2D warp. Experimental results on several challenging data sets show that our approach successfully registers images with self-occlusions while effectively detecting the self-occluded regions. PMID:19926901

  11. Visualization and analysis of occlusion for human jaws using a "functionally generated path"

    NASA Astrophysics Data System (ADS)

    Myszkowski, Karol; Herder, Jens; Kunii, Tosiyasu L.; Ibusuki, Masumi

    1996-03-01

    Dynamic characteristics of occlusion during lower jaw motion are useful in the diagnosis of jaw articulation problems and in computer-aided design/ manufacture of teeth restorations. The Functionally Generated Path (FGP), produced as a surface which envelops the actual occlusal surface of the moving opponent jaw, can be used for compact representation of dynamic occlusal relations. In traditional dentistry FGP is recorded as a bite impression in a patient's mouth. We propose an efficient computerized technique for FGP reconstruction and validate it through implementation and testing. The distance maps between occlusal surfaces of jaws, calculated for multiple projection directions and accumulated for mandibular motion, provide information for FGP computation. Rasterizing graphics hardware is used for fast calculation of the distance maps. Real-world data are used: the scanned shape of teeth and the measured motion of the lower jaw. We show applications of FGP to analysis of the occlusion relations and occlusal surface design for restorations.

  12. Complete wetting of graphene by biological lipids

    NASA Astrophysics Data System (ADS)

    Luan, Binquan; Huynh, Tien; Zhou, Ruhong

    2016-03-01

    Graphene nanosheets have been demonstrated to extract large amounts of lipid molecules directly out of the cell membrane of bacteria and thus cause serious damage to the cell's integrity. This interesting phenomenon, however, is so far not well understood theoretically. Here through extensive molecular dynamics simulations and theoretical analyses, we show that this phenomenon can be categorized as a complete wetting of graphene by membrane lipids in water. A wetting-based theory was utilized to associate the free energy change during the microscopic extraction of a lipid with the spreading parameter for the macroscopic wetting. With a customized thermodynamic cycle for detailed energetics, we show that the dispersive adhesion between graphene and lipids plays a dominant role during this extraction as manifested by the curved graphene. Our simulation results suggest that biological lipids can completely wet the concave, flat or even convex (with a small curvature) surface of a graphene sheet.Graphene nanosheets have been demonstrated to extract large amounts of lipid molecules directly out of the cell membrane of bacteria and thus cause serious damage to the cell's integrity. This interesting phenomenon, however, is so far not well understood theoretically. Here through extensive molecular dynamics simulations and theoretical analyses, we show that this phenomenon can be categorized as a complete wetting of graphene by membrane lipids in water. A wetting-based theory was utilized to associate the free energy change during the microscopic extraction of a lipid with the spreading parameter for the macroscopic wetting. With a customized thermodynamic cycle for detailed energetics, we show that the dispersive adhesion between graphene and lipids plays a dominant role during this extraction as manifested by the curved graphene. Our simulation results suggest that biological lipids can completely wet the concave, flat or even convex (with a small curvature) surface of a

  13. High temperature size selective membranes

    SciTech Connect

    Yates, S.F.; Swamikannu, A.X.

    1993-09-01

    The high temperature membrane, capable of operation above 550{degree}C, is designed to be a composite membrane composed of a thin layer of a size selective membrane supported by a microporous ceramic support. The kinetic diameters of H{sub 2} and CO{sub 2} are 2.96 {Angstrom} and 4.00 {Angstrom}. The thin layer will be made from CMS whose pore size will be controlled to be less than 4 {Angstrom}. The membrane will be truly size selective and be impermeable to carbon dioxide. The membrane will have higher selectivity than membranes which operate on Knudsen diffusion mechanism. The ceramic support will be fabricated from Allied Signal`s proprietary Blackglas{trademark} resin. The ceramic material, noted for its high thermal and oxidative resistance, has a coefficient of thermal expansion which matches closely that of CMS. The close match will insure mechanical integrity when the membrane is subjected to thermal cycles. The CMS layer will be produced by controlled pyrolysis of polymeric precursors. Pore size will be suitably modified by post-treatments to the carbon. The composite membrane will be tested for its permeation properties at 550{degree}C or higher. Thermal, mechanical and chemical stability of the membrane will be assessed. We have produced several samples of CMS from polymeric precursors. We have initiated work also on the preparation of microporous supports from Blackglas{trademark} resin. We have completed the design of the high temperature membrane pilot plant. The membrane cell was fabricated out of two kinds of stainless steel. The inner parts are made of SS 316 and the outer ring made of SS 420. The greater thermal expansion of the SS 316 will help obtain a leak free seal at the operating temperatures.

  14. Nd:YAG laser in occlusal caries prevention of primary teeth: a randomized clinical trial.

    PubMed

    Raucci-Neto, Walter; de Castro-Raucci, Larissa Moreira Spinola; Lepri, Cesar Penazzo; Faraoni-Romano, Juliana Jendiroba; Gomes da Silva, Jaciara Miranda; Palma-Dibb, Regina Guenka

    2015-02-01

    Dental caries is still the most prevalent chronic disease affecting human populations. Among the preventive treatments performed, it has been reported that laser irradiation combined with topical fluoride can induce an even greater increase in enamel caries resistance. The aim of this study was to evaluate the Nd:YAG laser, with or without fluoride, in occlusal caries prevention of the primary dentition. A double-blind split-mouth study design was used. Fifty-two children with high caries risk (7.6 ± 1.4 years) were selected and received the following: G1--the first molar was a negative control, and the second received a resin sealant; G2--the first molar was a negative control, and the second received laser irradiation (50 mJ, 10 Hz, 0.5 W); G3--the first molar received only acidulate phosphate fluoride (APF), and the second received APF + laser; G4--fisrt molar received only fluoride varnish, and the second received fluoride varnish + laser. Patients were followed up to 12 months to evaluate the presence of white-spot lesions and/or caries cavities by three calibrated observers. Thirty-five patients completed the study. Significant differences were found between the treatment and control groups (p < 0.05). The laser-alone and resin sealant resulted in statistically lower caries formation than the negative control group (p < 0.05). Nd:YAG laser irradiation in primary teeth effectively prevented occlusal caries in pits and fissures when used alone with lower energy over a 1-year period. PMID:23955196

  15. Early results of pulsed dye laser angioplasty with integral ball-tips in long femoral occlusions

    NASA Astrophysics Data System (ADS)

    Murray, Alan; Mitchell, David C.; Wood, Richard F. M.

    1990-07-01

    A Pulsed Dye laser together with specifically designed integral ball-tipped optical fibres have been used for the primary recanalisation of femoropopliteal vascular disease in 25 limbs of 23 patients. All patients had complete occlusions of the vessels ranging from 8-49cms in length (mean 22cms), having presented with critical ischaemia (18) or severe claudication warranting operative intervention (5). Pedal ulceration was present in 8 limbs and digital gangrene in 4. The laser produced visible light at 480nm in lOOmJ/lus pulses, at a frequency of 10-20Hz. The energy delivery device comprised a smooth atraumatic ball-tip constructed from the glass of the optical fibre, which was loaded retrogradely into a standard balloon angioplasty catheter. The device was introduced through a common femoral artery cutdown. Angiographic recanalisation was achieved in 22 of the 25 limbs with a mean energy of 280J(range 68-727J) and in each case the channel created by the laser fibre was augmented by balloon angioplasty. Technical failure occurred in three cases, caused by a wall dissection, persistent side-branch entry and incomplete lesion penetration respectively. Eighteen of procedures (72%) were clinically successful with marked symptomatic improvement. Of the four angiographic successful but clinical failures, acute occlusion within 48 hours occurred in 2 diabetic patients with very poor run-off and distal gangrene. The third case failed acutely due to a technically inadequate balloon dilatation and the fourth patient failed to improve symptomatically due to widespread with segmental tibial vessel disease below a successful recanalisation. Over a mean follow-up period of 7 months, three patients died of myocardial infarction. Twelve of the 23 patients (52%) remain well with patent vessels. These early results demonstrate the efficacy of pulsed dye laser angioplasty using ball-tipped optical fibres.

  16. Clinical indicators of paraplegia underplay universal spinal cord neuronal injury from transient aortic occlusion.

    PubMed

    Bell, Marshall T; Puskas, Ferenc; Bennett, Daine T; Cleveland, Joseph C; Herson, Paco S; Mares, Joshua M; Meng, Xainzhong; Weyant, Michael J; Fullerton, David A; Brett Reece, T

    2015-08-27

    Paraplegia following complex aortic intervention relies on crude evaluation of lower extremity strength such as whether the patient can lift their legs or flex the ankle. Little attention has been given to the possible long-term neurologic sequelae following these procedures in patients appearing functionally normal. We hypothesize that mice subjected to minimal ischemic time will have functional and histological changes despite the gross appearance of normal function. Male mice underwent 3 min of aortic occlusion (n=14) or sham surgery (n=4) via a median sternotomy. Neurologic function was graded by Basso Motor Score (BMS) preoperatively and at 24h intervals after reperfusion. Mice appearing functionally normal and sham mice were placed on a walking beam and recorded on high-definition, for single-frame motion analysis. After 96 hrs, spinal cords were removed for histological analysis. Following 3 min of ischemia, functional outcomes were split evenly with either mice displaying almost normal function n=7 or near complete paraplegia n=7. Additionally, single-frame motion analysis revealed significant changes in gait. Histologically, there was a significant stepwise reduction of neuronal viability, with even the normal function ischemic group demonstrating significant loss of neurons. Despite the appearance of normal function, temporary ischemia induced marked cyto-architectural changes and neuronal degeneration. Furthermore high-definition gait analysis revealed significant changes in gait and activity following thoracic aortic occlusion. These data suggest that all patients undergoing procedures, even with short ischemic times, may have spinal cord injury that is not evident clinically. PMID:26005132

  17. Carbon dioxide contrast medium for endovascular treatment of ilio-femoral occlusive disease

    PubMed Central

    de Almeida Mendes, Cynthia; de Arruda Martins, Alexandre; Teivelis, Marcelo Passos; Kuzniec, Sergio; Varella, Andrea Yasbek Monteiro; Fioranelli, Alexandre; Wolosker, Nelson

    2015-01-01

    OBJECTIVES: Compare the use of carbon dioxide contrast medium with iodine contrast medium for the endovascular treatment of ilio-femoral occlusive disease in patients without contraindications to iodine. MATERIALS AND METHODS: From August 2012 to August 2014, 21 consecutive patients with ilio-femoral occlusive disease who were eligible for endovascular treatment and lacked contraindications to either iodine contrast or carbon dioxide were randomized into the carbon dioxide or iodine groups and subjected to ilio-femoral angioplasty. We analyzed the feasibility of the procedures, the surgical and clinical outcomes, the procedure lengths, the endovascular material costs, the contrast costs and the quality of the angiographic images in each group. RESULTS: No conversions to open surgery and no contrast media related complications were noted in either group. A post-operative femoral pulse was present in 88.9% of the iodine group and 80% of the carbon dioxide group. No differences in procedure length, endovascular material cost or renal function variation were noted between the groups. Four patients in the carbon dioxide group required iodine supplementation to complete the procedure. Contrast media expenses were reduced in the carbon dioxide group. Regarding angiographic image quality, 82% of the carbon dioxide images were graded as either good or fair by observers. CONCLUSIONS: The use of carbon dioxide contrast medium is a good option for ilio-femoral angioplasty in patients without contraindications to iodine and is not characterized by differences in endovascular material costs, procedure duration and surgical outcomes. In addition, carbon dioxide has lower contrast expenses compared with iodine. PMID:26598079

  18. Robust lane sensing and departure warning under shadows and occlusions.

    PubMed

    Tapia-Espinoza, Rodolfo; Torres-Torriti, Miguel

    2013-01-01

    A prerequisite for any system that enhances drivers' awareness of road conditions and threatening situations is the correct sensing of the road geometry and the vehicle's relative pose with respect to the lane despite shadows and occlusions. In this paper we propose an approach for lane segmentation and tracking that is robust to varying shadows and occlusions. The approach involves color-based clustering, the use of MSAC for outlier removal and curvature estimation, and also the tracking of lane boundaries. Lane boundaries are modeled as planar curves residing in 3D-space using an inverse perspective mapping, instead of the traditional tracking of lanes in the image space, i.e., the segmented lane boundary points are 3D points in a coordinate frame fixed to the vehicle that have a depth component and belong to a plane tangent to the vehicle's wheels, rather than 2D points in the image space without depth information. The measurement noise and disturbances due to vehicle vibrations are reduced using an extended Kalman filter that involves a 6-DOF motion model for the vehicle, as well as measurements about the road's banking and slope angles. Additional contributions of the paper include: (i) the comparison of textural features obtained from a bank of Gabor filters and from a GMRF model; and (ii) the experimental validation of the quadratic and cubic approximations to the clothoid model for the lane boundaries. The results show that the proposed approach performs better than the traditional gradient-based approach under different levels of difficulty caused by shadows and occlusions. PMID:23478598

  19. Occlusion of the HIV poly(A) site.

    PubMed

    Weichs an der Glon, C; Monks, J; Proudfoot, N J

    1991-02-01

    To investigate the selective use of poly(A) sites in the 3' long terminal repeat (LTR) but not the 5' LTR of retroviruses, we have studied the poly(A) site of the human immunodeficiency virus (HIV-1). Using hybrid HIV/alpha-globin gene constructs, we demonstrate that the HIV poly(A) site is inactive or occluded when adjacent to an active promoter, either the homologous HIV promoter or the alpha-globin gene promoter. Furthermore, this occlusion of the HIV poly(A) site occurs over a considerable distance of up to at least 500 bp. In contrast, two nonretroviral poly(A) sites [alpha-globin and a synthetic poly(A) site] are active when close to a promoter. We also show that a short fragment of approximately 60 nucleotides containing the HIV poly(A) site is fully active when placed at the 3' end of the human alpha-globin gene or within the rabbit beta-globin gene. This result rules out the requirement of more distant upstream elements for the activity of the HIV poly(A) site, as has been suggested for other viral poly(A) sites. Finally, we show that the GT-rich downstream region of the HIV poly(A) site confers poly(A) site occlusion properties on a synthetic poly(A) site. This result focuses attention on this more variable part of a poly(A) site in retroviruses as a possible general signal for poly(A) site occlusion. PMID:1995416

  20. Coronary artery occlusion extends perfusion territory boundaries through microvascular collaterals.

    PubMed

    Cicutti, N; Rakusan, K; Downey, H F

    1994-01-01

    Simultaneous in vivo infusions of two different colored 10 microns microsphere suspensions into the left anterior descending (LAD; red spheres) and left circumflex (LCx; blue spheres) coronary arteries of nine anesthetized dogs identified a specific region of canine myocardium perfused by both arterial branches. Subsequently, the LAD was ligated and a third (green) set of micropheres was infused into the patent LCx artery. Analysis of 40 microns serial sections of tissue revealed interface zones with capillaries perfused by both arteries. The first zone, defined as the Interface Transistion Zone (ITZ) was formed by an intermingling of microvessels supplied by the parent arteries of the adjacent perfusion territories; it separated tissue containing only one or the other colored microspheres. Another zone, defined as the Boundary Watershed Zone was located within the ITZ and had capillaries containing both red and blue microspheres. The width of ITZ was 53377 +/- 817 microns (mean +/- SD), and the width of the BWZ was 3358 +/- 618 microns. Green microspheres, infused into the LCx following coronary occlusion were also found in the ITZ and BWZ. Furthermore, capillaries perfused exclusively by the LAD before occlusion (tissue with red but not blue microspheres) adjacent to the perfusion interface contained green microspheres as well as red/green aggregates, indicating lateral extension of the LCx perfusion territory. This extension of the LCx territory was quantitated by comparing the location at which densities of green microspheres or green/red aggregates decreased abruptly compared to the location of the original ITZ and BWZ boundaries, respectively. Results showed that LAD occlusion caused a 24% expansion of the ITZ and a 48% expansion of the BWZ. In addition, all expansions were significantly greater in subepicardial compared to subendocardial regions (p < 0.001). These results clearly demonstrate the capability of microvascular anastomoses in providing blood flow

  1. Sinusoidal obstruction syndrome (hepatic veno-occlusive disease).

    PubMed

    Fan, Cathy Q; Crawford, James M

    2014-12-01

    Hepatic sinusoidal obstruction syndrome (SOS) is an obliterative venulitis of the terminal hepatic venules, which in its more severe forms imparts a high risk of mortality. SOS, also known as veno-occlusive disease (VOD), occurs as a result of cytoreductive therapy prior to hematopoietic stem cell transplantation (HSCT), following oxaliplatin-containing adjuvant or neoadjuvant chemotherapy for colorectal carcinoma metastatic to the liver and treated by partial hepatectomy, in patients taking pyrrolizidine alkaloid-containing herbal remedies, and in other particular settings such as the autosomal recessive condition of veno-occlusive disease with immunodeficiency (VODI). A central pathogenic event is toxic destruction of hepatic sinusoidal endothelial cells (SEC), with sloughing and downstream occlusion of terminal hepatic venules. Contributing factors are SEC glutathione depletion, nitric oxide depletion, increased intrahepatic expression of matrix metalloproteinases and vascular endothelial growth factor (VEGF), and activation of clotting factors. The clinical presentation of SOS includes jaundice, development of right upper-quadrant pain and tender hepatomegaly, ascites, and unexplained weight gain. Owing to the potentially critical condition of these patients, transjugular biopsy may be the preferred route for liver biopsy to exclude other potential causes of liver dysfunction and to establish a diagnosis of SOS. Treatment includes rigorous fluid management so as to avoid excessive fluid overload while avoiding too rapid diuresis or pericentesis, potential use of pharmaceutics such as defibrotide, coagulolytic agents, or methylprednisolone, and liver transplantation. Proposed strategies for prevention and prophylaxis include reduced-intensity conditioning radiation for HSCT, treatment with ursodeoxycholic acid, and inclusion of bevacizumab with oxaliplatin-based chemotherapeutic regimes. While significant progress has been made in understanding the pathogenesis

  2. Robust Lane Sensing and Departure Warning under Shadows and Occlusions

    PubMed Central

    Tapia-Espinoza, Rodolfo; Torres-Torriti, Miguel

    2013-01-01

    A prerequisite for any system that enhances drivers' awareness of road conditions and threatening situations is the correct sensing of the road geometry and the vehicle's relative pose with respect to the lane despite shadows and occlusions. In this paper we propose an approach for lane segmentation and tracking that is robust to varying shadows and occlusions. The approach involves color-based clustering, the use of MSAC for outlier removal and curvature estimation, and also the tracking of lane boundaries. Lane boundaries are modeled as planar curves residing in 3D-space using an inverse perspective mapping, instead of the traditional tracking of lanes in the image space, i.e., the segmented lane boundary points are 3D points in a coordinate frame fixed to the vehicle that have a depth component and belong to a plane tangent to the vehicle's wheels, rather than 2D points in the image space without depth information. The measurement noise and disturbances due to vehicle vibrations are reduced using an extended Kalman filter that involves a 6-DOF motion model for the vehicle, as well as measurements about the road's banking and slope angles. Additional contributions of the paper include: (i) the comparison of textural features obtained from a bank of Gabor filters and from a GMRF model; and (ii) the experimental validation of the quadratic and cubic approximations to the clothoid model for the lane boundaries. The results show that the proposed approach performs better than the traditional gradient-based approach under different levels of difficulty caused by shadows and occlusions. PMID:23478598

  3. Extrapolation of vertical target motion through a brief visual occlusion.

    PubMed

    Zago, Myrka; Iosa, Marco; Maffei, Vincenzo; Lacquaniti, Francesco

    2010-03-01

    It is known that arbitrary target accelerations along the horizontal generally are extrapolated much less accurately than target speed through a visual occlusion. The extent to which vertical accelerations can be extrapolated through an occlusion is much less understood. Here, we presented a virtual target rapidly descending on a blank screen with different motion laws. The target accelerated under gravity (1g), decelerated under reversed gravity (-1g), or moved at constant speed (0g). Probability of each type of acceleration differed across experiments: one acceleration at a time, or two to three different accelerations randomly intermingled could be presented. After a given viewing period, the target disappeared for a brief, variable period until arrival (occluded trials) or it remained visible throughout (visible trials). Subjects were asked to press a button when the target arrived at destination. We found that, in visible trials, the average performance with 1g targets could be better or worse than that with 0g targets depending on the acceleration probability, and both were always superior to the performance with -1g targets. By contrast, the average performance with 1g targets was always superior to that with 0g and -1g targets in occluded trials. Moreover, the response times of 1g trials tended to approach the ideal value with practice in occluded protocols. To gain insight into the mechanisms of extrapolation, we modeled the response timing based on different types of threshold models. We found that occlusion was accompanied by an adaptation of model parameters (threshold time and central processing time) in a direction that suggests a strategy oriented to the interception of 1g targets at the expense of the interception of the other types of tested targets. We argue that the prediction of occluded vertical motion may incorporate an expectation of gravity effects. PMID:19882150

  4. [Prevalence of normal occlusion traits in deciduous dentition].

    PubMed

    Ferreira, R I; Barreira, A K; Soares, C D; Alves, A C

    2001-01-01

    The aim of this research was to study the normal occlusal patterns of deciduous dentition in Brazilian preschool children. The sample consisted of 356 preschool children, of both genders, aged 3-5 1/2 years from the urban zone of Salvador, Bahia. The occlusion exam was carried out by two examiners, in the classroom, utilizing a wooden spatula. The data were analyzed by the statistical program EPI-INFO 6.02 using the Chi-squared test. The frequency of the type I arch was 43.3% for the upper and 46.3% for the lower arch. The frequency of the type II arch was 56.7% for the upper and 53.75 for the lower arch, however, no difference between genders was noticed. The distribution of primate spaces was: 89.9% for the upper and 67.1% for the lower arch. This prevalence decreased significantly as age increased (p < 0.01). Normal canine relationship was found in almost 60% of the children for the right and left sides. Out of 712 evaluated terminal planes, 55.9% presented mesial terminal step for the primary second molars, 37.9% straight terminal plane and 6.2% distal step. The results permitted to conclude that the presence of generalized spacing between incisors, commonly described by other authors, was not the most prevailing condition for both arches in this sample. On the other hand, primate spaces were the most common ones. The most frequent normal occlusal patterns for canine and molar relationships were found to be the Class I patterns. PMID:11705312

  5. Sinusoidal Obstruction Syndrome (Hepatic Veno-Occlusive Disease)

    PubMed Central

    Fan, Cathy Q.; Crawford, James M.

    2014-01-01

    Hepatic sinusoidal obstruction syndrome (SOS) is an obliterative venulitis of the terminal hepatic venules, which in its more severe forms imparts a high risk of mortality. SOS, also known as veno-occlusive disease (VOD), occurs as a result of cytoreductive therapy prior to hematopoietic stem cell transplantation (HSCT), following oxaliplatin-containing adjuvant or neoadjuvant chemotherapy for colorectal carcinoma metastatic to the liver and treated by partial hepatectomy, in patients taking pyrrolizidine alkaloid-containing herbal remedies, and in other particular settings such as the autosomal recessive condition of veno-occlusive disease with immunodeficiency (VODI). A central pathogenic event is toxic destruction of hepatic sinusoidal endothelial cells (SEC), with sloughing and downstream occlusion of terminal hepatic venules. Contributing factors are SEC glutathione depletion, nitric oxide depletion, increased intrahepatic expression of matrix metalloproteinases and vascular endothelial growth factor (VEGF), and activation of clotting factors. The clinical presentation of SOS includes jaundice, development of right upper-quadrant pain and tender hepatomegaly, ascites, and unexplained weight gain. Owing to the potentially critical condition of these patients, transjugular biopsy may be the preferred route for liver biopsy to exclude other potential causes of liver dysfunction and to establish a diagnosis of SOS. Treatment includes rigorous fluid management so as to avoid excessive fluid overload while avoiding too rapid diuresis or pericentesis, potential use of pharmaceutics such as defibrotide, coagulolytic agents, or methylprednisolone, and liver transplantation. Proposed strategies for prevention and prophylaxis include reduced-intensity conditioning radiation for HSCT, treatment with ursodeoxycholic acid, and inclusion of bevacizumab with oxaliplatin-based chemotherapeutic regimes. While significant progress has been made in understanding the pathogenesis

  6. A New Occlusion Device: Application of the ArtVentive Endoluminal Occlusion System (EOS)—First in Human Clinical Trial

    SciTech Connect

    Venbrux, Anthony C.; Rudakov, Leon; Plass, Andre Emmert, Maximilian Y.; Ebner, Adrian

    2013-05-24

    PurposeThe purpose of this study was to determine the safety and efficacy of a new endoluminal occlusion device, ArtVentive endoluminal occlusion system (EOS), to occlude the spermatic vein in symptomatic males with varicoceles.MethodsThe ArtVentive EOS device has been developed for percutaneous, peripheral occlusion of the peripheral arterial and venous vasculature. The system is comprised of an implantable occlusion device and a delivery catheter. At present, there are two device sizes: (a) size 1 for target vessels ranging between 3.5 and 5.5 mm in diameter, and (b) size 2 for target vessels 5.5–8.5 mm in diameter. The treatment group included six adult males, ages 22–34 years. Nine target vessels were occluded. A total of 20 devices were implanted in six subjects.ResultsThe acute occlusion rate at the end of the procedure was 100 % occurring in nine of nine vessels. The spermatic veins of all patients remained occluded on venography at 30 days follow-up. Pain scores related to varicoceles decreased in five of six patients.ConclusionsAlthough we recognize this study is limited, initial experience indicates that the ArtVentive EOS is a safe and effective new device for occlusion of vessels (varicoceles). The device has potential applications in other clinical conditions requiring occlusion of veins or arteries.

  7. [Abrasion measurements in vivo in occlusal composite and amalgam fillings].

    PubMed

    Meier, C; Lutz, F

    1978-09-01

    A new method for quantitative measurement of occlusal wear on restorations is described. In a clinical evaluation with four different composites and an amalgam the method proved to be simple in execution and very exact. Statistical analysis after 7 months has shown significant differences in wear resistance of the different materials. The nature of the resulting wear was electron optically examined. Typical structural surface characteristics were observed for each of the different materials. More recently developed composities utilizing extremly small filler particles (Aerosil) seem to be comparable to amalgam in wear resistance. PMID:279445

  8. Dermatomyositis-Related Nonischemic Central Retinal Vein Occlusion.

    PubMed

    Wang, Yvonne; Morgan, Michael L; Espino Barros Palau, Angelina; Lee, Andrew G; Foroozan, Rod

    2015-09-01

    A 25-year-old woman with dermatomyositis suffered a right central retinal vein occlusion (CRVO) with visual acuity of 20/40. Examination of the right eye showed vitreous cells, suggesting inflammation of the central retinal vein leading to a CRVO as the presumed mechanism. She was admitted to hospital, and extensive evaluation was negative. She was maintained on corticosteroids to manage her dermatomyositis. One month later, she had macular edema and elevated intraocular pressure. Both resolved with dorzolamide, timolol, and intravitreal bevacizumab, and vision returned to 20/20 in the right eye. PMID:25815857

  9. Pulmonary Capillary Hemangiomatosis and Pulmonary Veno-occlusive Disease.

    PubMed

    Chaisson, Neal F; Dodson, Mark W; Elliott, Charles Gregory

    2016-09-01

    This article provides an overview of pulmonary veno-occlusive disease (PVOD) and pulmonary capillary hemangiomatosis (PCH), two disorders that challenge clinicians, radiologists, and pathologists because they often mimic pulmonary arterial hypertension (PAH). The article reviews the features that differentiate PVOD and PCH from PAH. The article also describes the overlap of PVOD and PCH, highlighted by recent reports of families diagnosed with PVOD or PCH caused by EIF2AK4 mutations. In addition, the article outlines current approaches to the diagnosis and treatment of PVOD and PCH. PMID:27514598

  10. Image-Guided Thromboembolectomy of Acute Arterial Occlusion in Children.

    PubMed

    Kim, Song-Yi; Han, Ahram; Choi, Chanjoong; Min, Sang-Il; Kim, Hyo-Cheol; Ha, Jongwon; Min, Seung-Kee

    2016-07-01

    Acute arterial thromboembolism (ATE) is rare in childhood, but this medical emergency requires immediate treatment. Described herein are separate instances of lower extremity ATE in 2 children, both of whom were successfully managed through image-guided thromboembolectomy (IGT). One patient, a 34-month-old female child with nephrotic syndrome, developed bilateral iliac and popliteal thromboembolic arterial occlusions after high-dose steroid therapy. Another 9-year-old girl suffered an embolism of left popliteal artery due to infectious endocarditis. Both patients underwent IGT using over-the-wire Fogarty catheters. During follow-up, presenting symptoms resolved without significant complications. PMID:27177711

  11. Strategies to prevent radial artery occlusion after transradial PCI.

    PubMed

    Pancholy, Samir B

    2014-07-01

    Radial artery occlusion (RAO) is the most common structural consequence of transradial access (TRA) with an estimated incidence ranging from 2-10 %. Its occurrence is free of any major clinical consequences, especially at rest, with most if not all cases of digital ischemia occurring as a result of embolization, rather than RAO. The incidence of RAO is unacceptably high if "best practices" are not followed. Strategies to prevent RAO need to be implemented to preserve radial artery patency in order to exploit other benefits of TRA. PMID:24890765

  12. Current status of percutaneous coronary intervention of chronic total occlusion

    PubMed Central

    Ge, Jun-bo

    2012-01-01

    This paper describes the current status of percutaneous coronary intervention (PCI) for totally occluded coronary arteries. Chronic total occlusion is associated with 10%–20% of all PCI procedures. Results show that opening an occluded vessel, especially one supplying a considerable area of myocardium, may be beneficial for a patient’s angina relief and heart function. We describe the devices used currently in re-canalization such as new wires, microcatheters (including Tonus and Cosair) and intravascular ultrasound guidance. Different techniques to improve the success rate and reduce complications are discussed in detail. PMID:22843178

  13. A hybrid approach to recanalization of a chronic iliofemoral occlusion.

    PubMed

    Ahanchi, Sadaf Sadie; Panneton, Jean Michel; Stout, Christopher Lee

    2013-01-01

    The Viabahn covered stent (W. L. Gore and Associates Inc, Flagstaff, Ariz) is made of expanded polytetrafluoroethylene attached to an external nitinol stent and is primarily used in the endovascular treatment of lower extremity arterial occlusive disease. The use of this device as an open conduit for lower extremity revascularization has been rarely reported. We expand on this experience by presenting a case of hybrid endovascular and open iliofemoral bypass in which we used the Viabahn endoprosthesis to recanalize an occluded iliac artery, followed by direct suturing of the distal portion of the Viabahn stent graft to the native common femoral artery bifurcation. PMID:22963813

  14. Growth and hemodynamics after early embryonic aortic arch occlusion*

    PubMed Central

    Lindsey, Stephanie E.; Menon, Prahlad G.; Kowalski, William J.; Shekhar, Akshay; Yalcin, Huseyin C.; Nishimura, Nozomi; Schaffer, Chris B.; Butcher, Jonathan T.; Pekkan, Kerem

    2015-01-01

    The majority of severe clinically significant forms of congenital heart disease (CHD) is associated with great artery lesions, including hypoplastic, double, right or interrupted aortic arch morphologies. While fetal and neonatal interventions are advancing, their potential ability to restore cardiac function, optimal timing, location, and intensity required for intervention remain largely unknown. We here combine computational fluid dynamics (CFD) simulations with in vivo experiments to test how individual pharyngeal arch artery hemodynamics alters as a result of local interventions to obstruct individual arch artery flow. Simulated isolated occlusions within each pharyngeal arch artery were created with image derived three-dimensional (3D) reconstructions of normal chick pharyngeal arch anatomy at Hamburger-Hamilton (HH) developmental stages HH18 and HH24. Acute flow redistributions were then computed using in vivo measured subject-specific aortic sinus inflow velocity profiles. A kinematic vascular growth-rendering algorithm was then developed and implemented to test the role of changing local wall shear stress patterns in downstream 3D morphogenesis of arch arteries. CFD simulations predicted that altered pressure gradients and flow redistributions were most sensitive to occlusion of the IVth arches. To evaluate these simulations experimentally, a novel in vivo experimental model of pharyngeal arch occlusion was developed and implemented using two-photon microscopy guided femtosecond laser based photodisruption surgery. The right IVth arch was occluded at HH18, and resulting diameter changes were followed for up to 24 hours. Pharyngeal arch diameter responses to acute hemodynamic changes were predicted qualitatively but poorly quantitatively. Chronic growth and adaptation to hemodynamic changes however were predicted in a subset of arches. Our findings suggest that this complex biodynamic process is governed through more complex forms of mechanobiological

  15. Left main coronary artery occlusion after percutaneous aortic valve implantation.

    PubMed

    Bartorelli, Antonio L; Andreini, Daniele; Sisillo, Erminio; Tamborini, Gloria; Fusari, Melissa; Biglioli, Paolo

    2010-03-01

    Left main coronary artery occlusion occurred immediately after transfemoral aortic valve implantation in an 87-year-old woman, which resulted in ventricular fibrillation and hemodynamic collapse. This life-threatening complication was promptly diagnosed with transesophageal echocardiography, which showed the disappearance of diastolic left main coronary artery jet flow and was confirmed with aortic root angiography. After prompt defibrillation, hemodynamic support was obtained with intra-aortic balloon pump and inotropic drugs. Functional recovery and survival were achieved with coronary stenting. This report highlights the importance of an integrated team approach of highly skilled specialists for these novel interventions. PMID:20172163

  16. Shape Tracking with Occlusions via Coarse-to-Fine Region-Based Sobolev Descent.

    PubMed

    Yang, Yanchao; Sundaramoorthi, Ganesh

    2015-05-01

    We present a method to track the shape of an object from video. The method uses a joint shape and appearance model of the object, which is propagated to match shape and radiance in subsequent frames, determining object shape. Self-occlusions and dis-occlusions of the object from camera and object motion pose difficulties to joint shape and appearance models in tracking. They are unable to adapt to new shape and appearance information, leading to inaccurate shape detection. In this work, we model self-occlusions and dis-occlusions in a joint shape and appearance tracking framework. Self-occlusions and the warp to propagate the model are coupled, thus we formulate a joint optimization problem. We derive a coarse-to-fine optimization method, advantageous in tracking, that initially perturbs the model by coarse perturbations before transitioning to finer-scale perturbations seamlessly. This coarse-to-fine behavior is automatically induced by gradient descent on a novel infinite-dimensional Riemannian manifold that we introduce. The manifold consists of planar parameterized regions, and the metric that we introduce is a novel Sobolev metric. Experiments on video exhibiting occlusions/dis-occlusions, complex radiance and background show that occlusion/dis-occlusion modeling leads to superior shape accuracy. PMID:26353328

  17. Selectively active markers for solving of the partial occlusion problem in matchmoving and chromakeying workflow

    NASA Astrophysics Data System (ADS)

    Mazurek, Przemysław

    2013-09-01

    Matchmoving (Match Moving) is the process used for the estimation of camera movements for further integration of acquired video image with computer graphics. The estimation of movements is possible using pattern recognition, 2D and 3D tracking algorithms. The main problem for the workflow is the partial occlusion of markers by the actor, because manual rotoscoping is necessary for fixing of the chroma-keyed footage. In the paper, the partial occlusion problem is solved using the invented, selectively active electronic markers. The sensor network with multiple infrared links detects occlusion state (no-occlusion, partial, full) and switch LED's based markers.

  18. Mechanical versus CO2 laser occlusion of the posterior semicircular canal in humans.

    PubMed

    Antonelli, P J; Lundy, L B; Kartush, J M; Burgio, D L; Graham, M D

    1996-05-01

    The purpose of this study was to compare the effectiveness of mechanical and laser-assisted posterior semicircular canal occlusion (PCO) for the treatment of intractable benign paroxysmal positional vertigo (BPPV). Twelve consecutive patients with intractable BPPV underwent PCO by three surgeons, six with mechanical PCO and six with CO2 laser-assisted PCO. PCO eliminated positional vertigo in all patients treated with the laser and five of six patients treated without the laser. Dysequilibrium was present in all patients immediately postoperatively. This resolved in all patients treated with the CO2 laser but in only two of six patients treated without the laser (p = 0.03). Patients were hospitalized for dysequilibrium for an average of 5.2 and 2.8 days for the mechanical and laser-assisted groups, respectively. Preoperative and postoperative hearing was not significantly different between the groups. No clinically significant postoperative hearing loss was encountered in either group. These results suggest that PCO is an effective treatment for intractable BPPV. The incidence of dysequilibrium that persists following PCO may be reduced by using the CO2 laser to seal the membranous canal prior to occluding the bony canal. PMID:8817019

  19. Membrane magic

    SciTech Connect

    Buecker, B.

    2005-09-01

    The Kansas Power and Light Co.'s La Cyne generating station has found success with membrane filtration water pretreatment technology. The article recounts the process followed in late 2004 to install a Pall Aria 4 microfilter in Unit 1 makeup water system at the plant to produce cleaner water for reverse osmosis feed. 2 figs., 2 photos.

  20. OXYGEN TRANSPORT CERAMIC MEMBRANES

    SciTech Connect

    Dr. Sukumar Bandopadhyay; Dr. Nagendra Nagabhushana

    2003-01-01

    In the present quarter, experiments are presented on ceramic/metal interactions of Zirconia/Ni-B-Si system and with a thin Ti coating deposited on zirconia surface. Processing of perovskites of LSC, LSF and LSCF composition for evaluation of mechanical properties as a function of environment are begun. The studies are to be in parallel with LSFCO composition to characterize the segregation of cations and slow crack growth in environmental conditions. La{sub 1-x}Sr{sub x}FeO{sub 3-d} has also been characterized for paramagnetic ordering at room temperature and the evolution of magnetic moments as a function of temperature are investigated. Investigation on the thermodynamic properties of the membrane materials are continued to develop a complete model for the membrane transport.

  1. Chronic total occlusion angioplasty in the United States.

    PubMed

    Grantham, J Aaron; Marso, Steven P; Spertus, John; House, John; Holmes, David R; Rutherford, Barry D

    2009-06-01

    Coronary chronic total occlusions (CTOs) are commonly encountered complex lesions identified in 15% of all patients referred for coronary angiography. Chronic total occlusion remains the most powerful predictor of referral for coronary bypass surgery. The benefits of CTO percutaneous coronary intervention (PCI) include symptom relief, improved left ventricular function, and potentially a survival advantage associated with success when compared with failed CTO-PCI. Data from the NCDR (National Cardiovascular Data Registry) suggest that CTO-PCI attempt rates in the U.S. have not changed over the past 5 years despite significant advances in techniques and technology, some of which we review here. Additionally, these data highlight a major disparity in attempt rates based on operator PCI volume. Remaining barriers to attempting CTO-PCI in the U.S. include operator inexperience, the perception of increased risk of CTO-PCI, and financial disincentives to operators and hospitals. To overcome operator inexperience, participation in CTO clubs, the invitation of guest operators, and a dedicated CTO day can be implemented at institutions committed to learning advanced CTO-PCI techniques so that operators can overcome the barriers and offer patients access to percutaneous therapy when it is clinically indicated. PMID:19539249

  2. Mouse Transient Global Ischemia Two-Vessel Occlusion Model

    PubMed Central

    Pontarelli, Fabrizio; Ofengeim, Dimitry; Zukin, R. Suzanne; Jonas, Elizabeth A.

    2016-01-01

    Transient global ischemia in rodents induces delayed death of hippocampal CA1 neurons, as well as in some hilar neurons of the dentate gyrus, medium aspiny neurons of the striatum, pyramidal neurons in neocortical layers II, V and VI, and Purkinje neurons of the cerebellum. In contrast to focal ischemia that mimics regional stroke in humans, this model of global ischemia mimics the brain injury that occurs after human cardiac arrest. Early events include caspase activation, cleavage of anti-death Bcl-2 family proteins and large mitochondrial channel activity. Genetically engineered mice provide opportunities for study such as the knock-in mouse expressing a caspase-resistant form of Bcl-xL found to exhibit markedly reduced mitochondrial channel activity and reduced vulnerability to ischemia-induced neuronal death1. It is therefore relevant to adapt and develop a simple protocol for producing transient global ischemia in mouse2. The two-vessel occlusion model has been specifically developed to provide optimal outcomes in mouse and offers several advantages over the four-vessel occlusion model traditionally used in rat including the relative ease of the procedure as well as only a single day of surgery. However it should be noted that this procedure has a higher morbidity rate compared to other ischemia models as well as a higher degree of variability. These two disadvantages necessitate the use of a larger cohort of animals, which for many healthy breeding transgenic animals is a non-deterring factor.

  3. Non-occlusive mesenteric ischaemia of a free jejunal flap.

    PubMed

    Onoda, Satoshi; Kimata, Yoshihiro; Yamada, Kiyoshi; Koshimune, Seijiro; Onoda, Tomoo; Shirakawa, Yasuhiro

    2013-05-01

    Free jejunal transfer using microsurgery after oesophageal or pharyngeal cancer resection is a useful operative approach. However, the disadvantage of free tissue transfer is the risk of necrosis of the transferred tissue due to impaired blood supply. In addition, jejunal flaps are more prone to blood-flow disorders such as ischaemia and congestion compared with other types of flaps. The causes of local blood supply disorders after microsurgery are divided broadly into two classes: one is thrombosis of an artery and/or vein in the anastomotic region and the other consists of local physical factors such as compressive pressure derived from haematoma formation and the effect of infection of the vascular pedicle. In this report, two rare cases of blood-flow disorder of the transferred free jejunum are described. In both cases, no signs of significant infection or occlusion of the vascular pedicles were present and late necrosis progressed gradually. The patients showed remarkable weight loss and a poor nutritional state due to inadequate preoperative nutritional intake. The necrosis was considered to be a result of non-occlusive mesenteric ischaemia of a free jejunal flap, and the factors contributing to free jejunal necrosis were reviewed. PMID:23395151

  4. Initial experience with hysteroscopic tubal occlusion (Essure®)

    PubMed Central

    Depes, Daniella De Batista; Pereira, Ana Maria Gomes; Lippi, Umberto Gazi; Martins, João Alfredo; Lopes, Reginaldo Guedes Coelho

    2016-01-01

    ABSTRACT Objective To evaluate results of early tubal occlusions performed by hysteroscopy (Essure®). Methods This prospective study included 38 patients, 73.7% of them were white, mean age 34.5 years, they have had on average 3 pregnancies and 2.7 of deliveries. A total of 86.8% of patients previously prepared the endometrium. All procedures were carried out at outpatient unit without anesthesia. Results Insertion rate of the device was 100% at a mean time of 4 minutes and 50 seconds. Based on the analogical visual scale, average pain reported was three, and 55.3% of women did not report pain after the procedure. After 3 months, 89.5% of patients were very satisfied with the method. Simple radiographs of the pelvis showed 92.1% of topical devices, and one case of unilateral expulsion had occurred. A four years follow-up did not show failure in the method. Conclusions Tubal occlusion through hysteroscopy at outpatient unit and without anesthesia was a quickly and well-tolerated procedure. No serious complications were seen, the success rate was high, and patients were satisfied. PMID:27462885

  5. Prevalence of Orthodontic Treatment Need and Occlusal Traits in Schoolchildren

    PubMed Central

    Jamilian, Abdolreza; Darnahal, Alireza; Damani, Elnaz; Talaeipour, Maziar; Kamali, Zinat

    2014-01-01

    Background. Widespread use of the IOTN along with detailed study of occlusal traits is suitable for planning community dental health resources. Objectives. The aim of current study was to assess the need for orthodontic treatment among school children of Tehran by means of the Dental Health Component (DHC) of the Index of Orthodontic Treatment Need (IOTN) and also to evaluate the occlusal traits of the subjects. Methods. 684 (343 boys and 341 girls) school children, 15 to 17 years of age, were selected at random from 12 schools to represent the four main areas of Tehran. The final sample who met the inclusion criteria comprised 643 subjects (322 males and 321 females). Malocclusion was determined with the Index of Orthodontic Treatment Need. The IOTN grades were statistically compared in the two genders using chi-square test. Results. Orthodontic treatment need, using the DHC, was found in only 9.0 per cent of the children. The prevalence of Angle Class I malocclusion in this study was higher than other malocclusions (65.2 per cent), followed by crowding in 62.7 per cent of the subjects. Conclusion. Orthodontic treatment need for Tehran high school students was relatively lower than that reported in most recent studies in Europe.

  6. Endoscopic bronchial occlusion with silicone spigots under virtual bronchoscopic navigation

    PubMed Central

    Sato, Shingo; Shiroyama, Takayuki; Nishida, Takuji; Nishihara, Takashi; Okamoto, Norio

    2016-01-01

    Abstract A 68‐year‐old woman with interstitial lung disease related to dermatomyositis and systemic scleroderma was admitted to our hospital with fever and dyspnoea. Although the fever was reduced after antibiotic therapy, a left pneumothorax suddenly occurred on day 27 after admission. A continuous air leak persisted despite chest drainage with three tubes and repeated pleurodesis. Chest computed tomography (CT) images showed a cavitary lesion with a pinhole in the left upper division, which was suspected to be the affected lesion with the air leak. Virtual bronchoscopic navigation images were constructed from CT data. Bronchial occlusion with Endobronchial Watanabe Spigots (EWSs) was performed on day 52. Two medium‐sized EWSs were inserted into the left B1 + 2a and B1 + 2b, and the air leak stopped immediately. No procedure‐related adverse events occurred. All three chest tubes were successfully removed by day 60. This case demonstrates that virtual bronchoscopic navigation can improve bronchial occlusion procedures using EWSs. PMID:27512560

  7. Complete analyticity for 2D Ising completed

    NASA Astrophysics Data System (ADS)

    Schonmann, Roberto H.; Shlosman, Senya B.

    1995-06-01

    We study the behavior of the two-dimensional nearest neighbor ferromagnetic Ising model under an external magnetic field h. We extend to every subcritical value of the temperature a result previously proven by Martirosyan at low enough temperature, and which roughly states that for finite systems with — boundary conditions under a positive external field, the boundary effect dominates in the bulk if the linear size of the system is of order B/h with B small enough, while if B is large enough, then the external field dominates in the bulk. As a consequence we are able to complete the proof that “complete analyticity for nice sets” holds for every value of the temperature and external field in the interior of the uniqueness region in the phase diagram of the model. The main tools used are the results and techniques developed to study large deviations for the block magnetization in the absence of the magnetic field, and recently extended to all temperatures below the critical one by Ioffe.

  8. Influence of different narrative instructions to record the occlusal contact with silicone registration materials.

    PubMed

    Obara, R; Komiyama, O; Iida, T; Asano, T; De Laat, A; Kawara, M

    2014-03-01

    This study examined the influence of narrative instructions on the occlusal contact area, occlusal contact point and masticatory muscle activities in normal subjects. Twelve healthy men and 12 healthy women with no more than one missing tooth per quadrant participated. Surface EMG was recorded from the masseter and temporal muscle. As a control measurement, intercuspal position was maintained to produce a habitual clenching record (NCR) while the occlusal contact area and occlusal contact point was recorded by means of silicone material. Subsequently, the occlusal contact area was recorded with the narrative instruction for minimum clenching record (MCR), light clenching record (LCR) and strong clenching record (HCR). While the EMG activity (%MVC) increased modestly from MCR to LCR (from 9·3 ± 2·0% to 11·5 ± 1·5%), the occlusal contact area increased rapidly (from 17·2 ± 11·3 mm(2) to 26·8 ± 15·6 mm(2) ) (P < 0·05). Both EMG activity and occlusal contact area increased gradually from LCR to NCR (to 17·7 ± 2·0% and to 31·4 ± 14·2 mm(2) , respectively). Finally, EMG activity still increased from NCR to HCR (to 44·5 ± 3·7%) (P < 0·05), but the occlusal contact area remained stable (to 36·8 ± 16·6 mm(2) ). Occlusal contact points at left posterior, right posterior, anterior and total area were not significantly different between each task. This study showed that narrative instructions while recording the bite can result in largely stable occlusal contact area. An adequate narrative instruction may therefore contribute to taking a stable occlusal recording in natural dentition. PMID:24447195

  9. Functional Development of the Coronary Collateral Circulation During Coronary Artery Occlusion in the Conscious Dog

    PubMed Central

    Bloor, Colin M.; White, Francis C.

    1972-01-01

    We studied changes in the coronary collateral circulation during coronary artery occlusion in 14 conscious dogs by: a) determining simultaneous changes in peripheral coronary pressure (PCP) and retrograde flow (RF) after abrupt coronary artery occlusion; b) correlating these functional indices with quantitative anatomic indices (AI) of coronary collateral development (Menick et al: Am Heart J 82:503-510, 1971); and c) observing changes in these indices after repeated reocclusions of a coronary artery. These dogs were subjected to left circumflex coronary artery (LCCA) occlusions for 2 hours to 8 days; pressure tubes were implanted in the aorta and LCCA, the latter tube placed distal to an occlusive cuff for PCP and RF measurements. Afterwards the animals were sacrificed, their hearts injected with a modified Schlesinger's gelatin mass, and AI determined. During 2 to 24 hour LCCA occlusions (11 dogs) mean PCP rose to levels 50 to 80% of prevailing aortic pressure. During repreated 2- to 24-hour occlusions (2 dogs) in the same dog, the rate at which PCP rose increased. Retrograde flow was unchanged during 2- to 24-hour occlusions. Anatomic indices of these dogs were in the same range as those observed in unoccluded controls. When LCCA occlusion was maintained for more than 4 days (3 dogs), mean PCP rose during the first 24 hours and then remained stable; RF did not change until 4 days into occlusion and then increased. Anatomic indices of dogs occluded for more than 4 days were significantly greater (P < 0.001) than those of the 2- to 24-hour occlusion groups. Our study shows that: a) the early PCP rise after occlusion is not associated with an increase in RF, b) RF is a better index of collateral function and c) RF correlated well with the anatomic development of the collateral bed. ImagesFig 2Fig 1 PMID:5033259

  10. The Effect of Photoluminescence of Bioceramic Irradiation on Middle Cerebral Arterial Occlusion in Rats.

    PubMed

    Zhang, Lei; Chan, Paul; Liu, Zhong-Min; Hwang, Ling-Ling; Lin, Kuo-Chi; Chan, Wing P; Leung, Ting-Kai; Choy, Cheuk Sing

    2016-01-01

    The purpose of this study is to determine the possible effect of photoluminescence of bioceramic (PLB) on ischemic cerebral infarction (stroke), by using an animal model of transient middle cerebral artery occlusion (MCAO). Sprague-Dawley rats were used to induce MCAO to block the origin of the left MCAO; three months later, the positive chronic stroke rats were selected by running tunnel maze; the MCAO rats with significant chronic stroke and neurological defects were used for treadmill experiments with varying speed settings to test their capability for restoration after muscular fatigue under conditions of with and without PLB irradiation. As a result, PLB irradiation could improve exercise completion rate and average running speed during slow and fast treadmill settings. After PLB irradiation, the selected MCAO rats successfully completed all the second-round treadmill exercises at the maximum speed setting, and they had better restoration from muscular fatigue. An in vitro cell study on astrocytes of rats by bioceramic irradiation further demonstrated increased intracellular nitric oxide. To explain these results, we suggest that cortical brain stimulation of microcirculation and enhancement of peripheral muscular activity are the main causes of the improved exercise performance in MCAO rats by PLB. PMID:27375765

  11. The Effect of Photoluminescence of Bioceramic Irradiation on Middle Cerebral Arterial Occlusion in Rats

    PubMed Central

    Zhang, Lei; Chan, Paul; Liu, Zhong-Min; Hwang, Ling-Ling; Lin, Kuo-Chi; Chan, Wing P.; Leung, Ting-Kai; Choy, Cheuk Sing

    2016-01-01

    The purpose of this study is to determine the possible effect of photoluminescence of bioceramic (PLB) on ischemic cerebral infarction (stroke), by using an animal model of transient middle cerebral artery occlusion (MCAO). Sprague-Dawley rats were used to induce MCAO to block the origin of the left MCAO; three months later, the positive chronic stroke rats were selected by running tunnel maze; the MCAO rats with significant chronic stroke and neurological defects were used for treadmill experiments with varying speed settings to test their capability for restoration after muscular fatigue under conditions of with and without PLB irradiation. As a result, PLB irradiation could improve exercise completion rate and average running speed during slow and fast treadmill settings. After PLB irradiation, the selected MCAO rats successfully completed all the second-round treadmill exercises at the maximum speed setting, and they had better restoration from muscular fatigue. An in vitro cell study on astrocytes of rats by bioceramic irradiation further demonstrated increased intracellular nitric oxide. To explain these results, we suggest that cortical brain stimulation of microcirculation and enhancement of peripheral muscular activity are the main causes of the improved exercise performance in MCAO rats by PLB. PMID:27375765

  12. Mild Sensory Stimulation Completely Protects the Adult Rodent Cortex from Ischemic Stroke

    PubMed Central

    Chen-Bee, Cynthia H.; Frostig, Ron D.

    2010-01-01

    Despite progress in reducing ischemic stroke damage, complete protection remains elusive. Here we demonstrate that, after permanent occlusion of a major cortical artery (middle cerebral artery; MCA), single whisker stimulation can induce complete protection of the adult rat cortex, but only if administered within a critical time window. Animals that receive early treatment are histologically and behaviorally equivalent to healthy controls and have normal neuronal function. Protection of the cortex clearly requires reperfusion to the ischemic area despite permanent occlusion. Using blood flow imaging and other techniques we found evidence of reversed blood flow into MCA branches from an alternate arterial source via collateral vessels (inter-arterial connections), a potential mechanism for reperfusion. These findings suggest that the cortex is capable of extensive blood flow reorganization and more importantly that mild sensory stimulation can provide complete protection from impending stroke given early intervention. Such non-invasive, non-pharmacological intervention has clear translational potential. PMID:20585659

  13. Latino College Completion: Oklahoma

    ERIC Educational Resources Information Center

    Excelencia in Education (NJ1), 2012

    2012-01-01

    In 2009, Excelencia in Education launched the Ensuring America's Future initiative to inform, organize, and engage leaders in a tactical plan to increase Latino college completion. An executive summary of Latino College Completion in 50 states synthesizes information on 50 state factsheets and builds on the national benchmarking guide. Each…

  14. Latino College Completion: Washington

    ERIC Educational Resources Information Center

    Excelencia in Education (NJ1), 2012

    2012-01-01

    In 2009, Excelencia in Education launched the Ensuring America's Future initiative to inform, organize, and engage leaders in a tactical plan to increase Latino college completion. An executive summary of Latino College Completion in 50 states synthesizes information on 50 state factsheets and builds on the national benchmarking guide. Each…

  15. Latino College Completion: Wisconsin

    ERIC Educational Resources Information Center

    Excelencia in Education (NJ1), 2012

    2012-01-01

    In 2009, Excelencia in Education launched the Ensuring America's Future initiative to inform, organize, and engage leaders in a tactical plan to increase Latino college completion. An executive summary of Latino College Completion in 50 states synthesizes information on 50 state factsheets and builds on the national benchmarking guide. Each…

  16. Latino College Completion: Wyoming

    ERIC Educational Resources Information Center

    Excelencia in Education (NJ1), 2012

    2012-01-01

    In 2009, Excelencia in Education launched the Ensuring America's Future initiative to inform, organize, and engage leaders in a tactical plan to increase Latino college completion. An executive summary of Latino College Completion in 50 states synthesizes information on 50 state factsheets and builds on the national benchmarking guide. Each…

  17. Latino College Completion: Utah

    ERIC Educational Resources Information Center

    Excelencia in Education (NJ1), 2012

    2012-01-01

    In 2009, Excelencia in Education launched the Ensuring America's Future initiative to inform, organize, and engage leaders in a tactical plan to increase Latino college completion. An executive summary of Latino College Completion in 50 states synthesizes information on 50 state factsheets and builds on the national benchmarking guide. Each…

  18. Latino College Completion: Massachusetts

    ERIC Educational Resources Information Center

    Excelencia in Education (NJ1), 2012

    2012-01-01

    In 2009, Excelencia in Education launched the Ensuring America's Future initiative to inform, organize, and engage leaders in a tactical plan to increase Latino college completion. An executive summary of Latino College Completion in 50 states synthesizes information on 50 state factsheets and builds on the national benchmarking guide. Each…

  19. Latino College Completion: Kansas

    ERIC Educational Resources Information Center

    Excelencia in Education (NJ1), 2012

    2012-01-01

    In 2009, Excelencia in Education launched the Ensuring America's Future initiative to inform, organize, and engage leaders in a tactical plan to increase Latino college completion. An executive summary of Latino College Completion in 50 states synthesizes information on 50 state factsheets and builds on the national benchmarking guide. Each…

  20. Latino College Completion: Colorado

    ERIC Educational Resources Information Center

    Excelencia in Education (NJ1), 2012

    2012-01-01

    In 2009, Excelencia in Education launched the Ensuring America's Future initiative to inform, organize, and engage leaders in a tactical plan to increase Latino college completion. An executive summary of Latino College Completion in 50 states synthesizes information on 50 state factsheets and builds on the national benchmarking guide. Each…

  1. Latino College Completion: Alabama

    ERIC Educational Resources Information Center

    Excelencia in Education (NJ1), 2012

    2012-01-01

    In 2009, Excelencia in Education launched the Ensuring America's Future initiative to inform, organize, and engage leaders in a tactical plan to increase Latino college completion. An executive summary of Latino College Completion in 50 states synthesizes information on 50 state factsheets and builds on the national benchmarking guide. Each…

  2. Latino College Completion: Arizona

    ERIC Educational Resources Information Center

    Excelencia in Education (NJ1), 2012

    2012-01-01

    In 2009, Excelencia in Education launched the Ensuring America's Future initiative to inform, organize, and engage leaders in a tactical plan to increase Latino college completion. An executive summary of Latino College Completion in 50 states synthesizes information on 50 state factsheets and builds on the national benchmarking guide. Each…

  3. Latino College Completion: Michigan

    ERIC Educational Resources Information Center

    Excelencia in Education (NJ1), 2012

    2012-01-01

    In 2009, Excelencia in Education launched the Ensuring America's Future initiative to inform, organize, and engage leaders in a tactical plan to increase Latino college completion. An executive summary of Latino College Completion in 50 states synthesizes information on 50 state factsheets and builds on the national benchmarking guide. Each…

  4. Latino College Completion: Illinois

    ERIC Educational Resources Information Center

    Excelencia in Education (NJ1), 2012

    2012-01-01

    In 2009, Excelencia in Education launched the Ensuring America's Future initiative to inform, organize, and engage leaders in a tactical plan to increase Latino college completion. An executive summary of Latino College Completion in 50 states synthesizes information on 50 state factsheets and builds on the national benchmarking guide. Each…

  5. Latino College Completion: Minnesota

    ERIC Educational Resources Information Center

    Excelencia in Education (NJ1), 2012

    2012-01-01

    In 2009, Excelencia in Education launched the Ensuring America's Future initiative to inform, organize, and engage leaders in a tactical plan to increase Latino college completion. An executive summary of Latino College Completion in 50 states synthesizes information on 50 state factsheets and builds on the national benchmarking guide. Each…

  6. Latino College Completion: Maine

    ERIC Educational Resources Information Center

    Excelencia in Education (NJ1), 2012

    2012-01-01

    In 2009, Excelencia in Education launched the Ensuring America's Future initiative to inform, organize, and engage leaders in a tactical plan to increase Latino college completion. An executive summary of Latino College Completion in 50 states synthesizes information on 50 state factsheets and builds on the national benchmarking guide. Each…

  7. Latino College Completion: Connecticut

    ERIC Educational Resources Information Center

    Excelencia in Education (NJ1), 2012

    2012-01-01

    In 2009, Excelencia in Education launched the Ensuring America's Future initiative to inform, organize, and engage leaders in a tactical plan to increase Latino college completion. An executive summary of Latino College Completion in 50 states synthesizes information on 50 state factsheets and builds on the national benchmarking guide. Each…

  8. Latino College Completion: Indiana

    ERIC Educational Resources Information Center

    Excelencia in Education (NJ1), 2012

    2012-01-01

    In 2009, Excelencia in Education launched the Ensuring America's Future initiative to inform, organize, and engage leaders in a tactical plan to increase Latino college completion. An executive summary of Latino College Completion in 50 states synthesizes information on 50 state factsheets and builds on the national benchmarking guide. Each…

  9. Latino College Completion: Maryland

    ERIC Educational Resources Information Center

    Excelencia in Education (NJ1), 2012

    2012-01-01

    In 2009, Excelencia in Education launched the Ensuring America's Future initiative to inform, organize, and engage leaders in a tactical plan to increase Latino college completion. An executive summary of Latino College Completion in 50 states synthesizes information on 50 state factsheets and builds on the national benchmarking guide. Each…

  10. Latino College Completion: Arkansas

    ERIC Educational Resources Information Center

    Excelencia in Education (NJ1), 2012

    2012-01-01

    In 2009, Excelencia in Education launched the Ensuring America's Future initiative to inform, organize, and engage leaders in a tactical plan to increase Latino college completion. An executive summary of Latino College Completion in 50 states synthesizes information on 50 state factsheets and builds on the national benchmarking guide. Each…

  11. Latino College Completion: Delaware

    ERIC Educational Resources Information Center

    Excelencia in Education (NJ1), 2012

    2012-01-01

    In 2009, Excelencia in Education launched the Ensuring America's Future initiative to inform, organize, and engage leaders in a tactical plan to increase Latino college completion. An executive summary of Latino College Completion in 50 states synthesizes information on 50 state factsheets and builds on the national benchmarking guide. Each…

  12. Latino College Completion: Alaska

    ERIC Educational Resources Information Center

    Excelencia in Education (NJ1), 2012

    2012-01-01

    In 2009, Excelencia in Education launched the Ensuring America's Future initiative to inform, organize, and engage leaders in a tactical plan to increase Latino college completion. An executive summary of Latino College Completion in 50 states synthesizes information on 50 state factsheets and builds on the national benchmarking guide. Each…

  13. Latino College Completion: Kentucky

    ERIC Educational Resources Information Center

    Excelencia in Education (NJ1), 2012

    2012-01-01

    In 2009, Excelencia in Education launched the Ensuring America's Future initiative to inform, organize, and engage leaders in a tactical plan to increase Latino college completion. An executive summary of Latino College Completion in 50 states synthesizes information on 50 state factsheets and builds on the national benchmarking guide. Each…

  14. Latino College Completion: Mississippi

    ERIC Educational Resources Information Center

    Excelencia in Education (NJ1), 2012

    2012-01-01

    In 2009, Excelencia in Education launched the Ensuring America's Future initiative to inform, organize, and engage leaders in a tactical plan to increase Latino college completion. An executive summary of Latino College Completion in 50 states synthesizes information on 50 state factsheets and builds on the national benchmarking guide. Each…

  15. Latino College Completion: Nevada

    ERIC Educational Resources Information Center

    Excelencia in Education (NJ1), 2012

    2012-01-01

    In 2009, Excelencia in Education launched the Ensuring America's Future initiative to inform, organize, and engage leaders in a tactical plan to increase Latino college completion. An executive summary of Latino College Completion in 50 states synthesizes information on 50 state factsheets and builds on the national benchmarking guide. Each…

  16. Latino College Completion: California

    ERIC Educational Resources Information Center

    Excelencia in Education (NJ1), 2012

    2012-01-01

    In 2009, Excelencia in Education launched the Ensuring America's Future initiative to inform, organize, and engage leaders in a tactical plan to increase Latino college completion. An executive summary of Latino College Completion in 50 states synthesizes information on 50 state factsheets and builds on the national benchmarking guide. Each…

  17. Latino College Completion: Missouri

    ERIC Educational Resources Information Center

    Excelencia in Education (NJ1), 2012

    2012-01-01

    In 2009, Excelencia in Education launched the Ensuring America's Future initiative to inform, organize, and engage leaders in a tactical plan to increase Latino college completion. An executive summary of Latino College Completion in 50 states synthesizes information on 50 state factsheets and builds on the national benchmarking guide. Each…

  18. Latino College Completion: Nebraska

    ERIC Educational Resources Information Center

    Excelencia in Education (NJ1), 2012

    2012-01-01

    In 2009, Excelencia in Education launched the Ensuring America's Future initiative to inform, organize, and engage leaders in a tactical plan to increase Latino college completion. An executive summary of Latino College Completion in 50 states synthesizes information on 50 state factsheets and builds on the national benchmarking guide. Each…

  19. Latino College Completion: Vermont

    ERIC Educational Resources Information Center

    Excelencia in Education (NJ1), 2012

    2012-01-01

    In 2009, Excelencia in Education launched the Ensuring America's Future initiative to inform, organize, and engage leaders in a tactical plan to increase Latino college completion. An executive summary of Latino College Completion in 50 states synthesizes information on 50 state factsheets and builds on the national benchmarking guide. Each…

  20. Latino College Completion: Montana

    ERIC Educational Resources Information Center

    Excelencia in Education (NJ1), 2012

    2012-01-01

    In 2009, Excelencia in Education launched the Ensuring America's Future initiative to inform, organize, and engage leaders in a tactical plan to increase Latino college completion. An executive summary of Latino College Completion in 50 states synthesizes information on 50 state factsheets and builds on the national benchmarking guide. Each…

  1. Latino College Completion: Florida

    ERIC Educational Resources Information Center

    Excelencia in Education (NJ1), 2012

    2012-01-01

    In 2009, Excelencia in Education launched the Ensuring America's Future initiative to inform, organize, and engage leaders in a tactical plan to increase Latino college completion. An executive summary of Latino College Completion in 50 states synthesizes information on 50 state factsheets and builds on the national benchmarking guide. Each…

  2. Latino College Completion: Oregon

    ERIC Educational Resources Information Center

    Excelencia in Education (NJ1), 2012

    2012-01-01

    In 2009, Excelencia in Education launched the Ensuring America's Future initiative to inform, organize, and engage leaders in a tactical plan to increase Latino college completion. An executive summary of Latino College Completion in 50 states synthesizes information on 50 state factsheets and builds on the national benchmarking guide. Each…

  3. Latino College Completion: Louisiana

    ERIC Educational Resources Information Center

    Excelencia in Education (NJ1), 2012

    2012-01-01

    In 2009, Excelencia in Education launched the Ensuring America's Future initiative to inform, organize, and engage leaders in a tactical plan to increase Latino college completion. An executive summary of Latino College Completion in 50 states synthesizes information on 50 state factsheets and builds on the national benchmarking guide. Each…

  4. Latino College Completion: Ohio

    ERIC Educational Resources Information Center

    Excelencia in Education (NJ1), 2012

    2012-01-01

    In 2009, Excelencia in Education launched the Ensuring America's Future initiative to inform, organize, and engage leaders in a tactical plan to increase Latino college completion. An executive summary of Latino College Completion in 50 states synthesizes information on 50 state factsheets and builds on the national benchmarking guide. Each…

  5. Latino College Completion: Hawaii

    ERIC Educational Resources Information Center

    Excelencia in Education (NJ1), 2012

    2012-01-01

    In 2009, Excelencia in Education launched the Ensuring America's Future initiative to inform, organize, and engage leaders in a tactical plan to increase Latino college completion. An executive summary of Latino College Completion in 50 states synthesizes information on 50 state factsheets and builds on the national benchmarking guide. Each…

  6. Latino College Completion: Idaho

    ERIC Educational Resources Information Center

    Excelencia in Education (NJ1), 2012

    2012-01-01

    In 2009, Excelencia in Education launched the Ensuring America's Future initiative to inform, organize, and engage leaders in a tactical plan to increase Latino college completion. An executive summary of Latino College Completion in 50 states synthesizes information on 50 state factsheets and builds on the national benchmarking guide. Each…

  7. Latino College Completion: Iowa

    ERIC Educational Resources Information Center

    Excelencia in Education (NJ1), 2012

    2012-01-01

    In 2009, Excelencia in Education launched the Ensuring America's Future initiative to inform, organize, and engage leaders in a tactical plan to increase Latino college completion. An executive summary of Latino College Completion in 50 states synthesizes information on 50 state factsheets and builds on the national benchmarking guide. Each…

  8. Latino College Completion: Tennessee

    ERIC Educational Resources Information Center

    Excelencia in Education (NJ1), 2012

    2012-01-01

    In 2009, Excelencia in Education launched the Ensuring America's Future initiative to inform, organize, and engage leaders in a tactical plan to increase Latino college completion. An executive summary of Latino College Completion in 50 states synthesizes information on 50 state factsheets and builds on the national benchmarking guide. Each…

  9. Latino College Completion: Pennsylvania

    ERIC Educational Resources Information Center

    Excelencia in Education (NJ1), 2012

    2012-01-01

    In 2009, Excelencia in Education launched the Ensuring America's Future initiative to inform, organize, and engage leaders in a tactical plan to increase Latino college completion. An executive summary of Latino College Completion in 50 states synthesizes information on 50 state factsheets and builds on the national benchmarking guide. Each…

  10. Latino College Completion: Georgia

    ERIC Educational Resources Information Center

    Excelencia in Education (NJ1), 2012

    2012-01-01

    In 2009, Excelencia in Education launched the Ensuring America's Future initiative to inform, organize, and engage leaders in a tactical plan to increase Latino college completion. An executive summary of Latino College Completion in 50 states synthesizes information on 50 state factsheets and builds on the national benchmarking guide. Each…

  11. Latino College Completion: Virginia

    ERIC Educational Resources Information Center

    Excelencia in Education (NJ1), 2012

    2012-01-01

    In 2009, Excelencia in Education launched the Ensuring America's Future initiative to inform, organize, and engage leaders in a tactical plan to increase Latino college completion. An executive summary of Latino College Completion in 50 states synthesizes information on 50 state factsheets and builds on the national benchmarking guide. Each…

  12. Latino College Completion: Texas

    ERIC Educational Resources Information Center

    Excelencia in Education (NJ1), 2012

    2012-01-01

    In 2009, Excelencia in Education launched the Ensuring America's Future initiative to inform, organize, and engage leaders in a tactical plan to increase Latino college completion. An executive summary of Latino College Completion in 50 states synthesizes information on 50 state factsheets and builds on the national benchmarking guide. Each…

  13. Classical versus quantum completeness

    NASA Astrophysics Data System (ADS)

    Hofmann, Stefan; Schneider, Marc

    2015-06-01

    The notion of quantum-mechanical completeness is adapted to situations where the only adequate description is in terms of quantum field theory in curved space-times. It is then shown that Schwarzschild black holes, although geodesically incomplete, are quantum complete.

  14. [Membranous nephropathy].

    PubMed

    Mercadal, Lucile

    2013-12-01

    Membranous nephropathy is characterized by immune complex deposits on the outer side of the glomerular basement membrane. Activation of complement and of oxidation lead to basement membrane lesions. The most frequent form is idiopathic. At 5 and 10 years, renal survival is around 90 and 65% respectively. A prognostic model based on proteinuria, level and duration, progression of renal failure in a few months can refine prognosis. The urinary excretion of C5b-9, β2 and α1 microglobuline and IgG are strong predictors of outcome. Symptomatic treatment is based on anticoagulation in case of nephrotic syndrome, angiotensin conversion enzyme inhibitors, angiotensin II receptor blockers and statins. Immunosuppressive therapy should be discussed for patients having a high risk of progression. Corticoids alone has no indication. Treatment should include a simultaneous association or more often alternating corticoids and alkylant agent for a minimum of 6 months. Adrenocorticoid stimulating hormone and steroids plus mycophenolate mofetil may be equally effective. Steroids plus alkylant decrease the risk of end stage renal failure. Cyclosporine and tacrolimus decrease proteinuria but are associated with a high risk of recurrence at time of withdrawal and are nephrotoxic. Rituximab evaluated on open studies needs further evaluations to define its use. PMID:24315535

  15. Initial and Long-Term Results of Endovascular Therapy for Chronic Total Occlusion of the Subclavian Artery

    SciTech Connect

    Babic, Srdjan; Sagic, Dragan; Radak, Djordje; Antonic, Zelimir; Otasevic, Petar; Kovacevic, Vladimir; Tanaskovic, Slobodan; Ruzicic, Dusan; Aleksic, Nikola; Vucurevic, Goran

    2012-04-15

    Purpose: To study the initial and long-term results of angioplasty and primary stenting for the treatment of chronic total occlusion (CTO) of the subclavian artery (SA). Materials and Methods: From January 1999 to February 2010, 56 patients (25 men with a mean age of 58 {+-} 8 years) underwent endovascular treatment for CTO of the SA. Duplex scans and arteriograms confirmed occlusion in all cases. Indications for recanalization were subclavian steal syndrome in 33 patients (58.1%), arm claudication in 13 patients (23.2%), and coronary ischemia in 7 patients (12.5%) who had a history of previous coronary artery bypass grafting that included left internal thoracic artery graft. Three patients (5.4%) were treated before the scheduled coronary artery bypass surgery, which included left internal thoracic artery graft. After successful recanalization, all arteries were stented, and all of the patients were followed-up at 1, 3, 6, and 12 months after surgery and annually thereafter. Results: Successful recanalization of the SA was achieved in 46 patients (82.1%), and the complication rate was 7.1%. During follow-up (mean 40 {+-} 26 months; range 2 to 125), the primary patency rates after 1 and 3 years were 97.9% and 82.7%, respectively. At the end of follow-up, 76% of the arteries showed no evidence of restenosis. Univariate analysis failed to identify any variable predictive of long-term patency of successfully recanalized SA. Conclusion: Percutaneous transluminal angioplasty with stenting of the complete total occlusion of the SA is a safe and effective procedure associated with low risks and good long-term results.

  16. Effects of BRL 38227, sodium nitroprusside and verapamil on collateral perfusion following acute arterial occlusion in the rabbit isolated ear.

    PubMed Central

    Randall, M. D.; Griffith, T. M.

    1992-01-01

    1. We have used an isolated, buffer-perfused, rabbit ear model of acute arterial occlusion to investigate the effects of the nitrovasodilator sodium nitroprusside, the potassium channel activator BRL 38227 (the active (-)-enantiomer of cromakalim) and the calcium antagonist, verapamil, on collateral perfusion in the absence of pharmacological tone. 2. Verapamil was the most potent vasodilator (EC50 = 72.6 +/- 32.0 nM) of 5-hydroxytryptamine/histamine-induced tone in the rabbit isolated perfused ear. Sodium nitroprusside and BRL 38227 were less potent with respective EC50 values of 488 +/- 75 nM and 296 +/- 40 nM. Following inhibition of endothelium-derived relaxing factor (EDRF) synthesis, the potency of BRL 38227 was significantly (P less than 0.001) increased with an EC50 of 55.6 +/- 5.0 nM. 3. BRL 38227 at 500 nM and 3 microM induced substantial increases in collateral perfusion following arterial ligation in the absence of pharmacological tone compared to control. Furthermore 3 microM BRL 38227 completely reversed the attenuation of collateral perfusion which followed inhibition of EDRF synthesis with 100 microM NG-nitro-L-arginine methyl ester (L-NAME). 4. Sodium nitroprusside (500 nM and 3 microM) induced modest improvements in collateral perfusion in the early stages after arterial occlusion. 5. Verapamil did not influence collateral perfusion at either of the concentrations used (50 nM and 3 microM), even though it was a potent vasodilator. 6. The results of this study indicate that BRL 38227, and to a much lesser extent sodium nitroprusside, selectively improve collateral perfusion following arterial occlusion, even in the presence of effects of EDRF on acute collateralization, while verapamil has no effect.(ABSTRACT TRUNCATED AT 250 WORDS) Images Figure 1 PMID:1393264

  17. Preparation and characterization of novel antibacterial castor oil-based polyurethane membranes for wound dressing application.

    PubMed

    Yari, Abbas; Yeganeh, Hamid; Bakhshi, Hadi; Gharibi, Reza

    2014-01-01

    Preparation of novel antibacterial and cytocompatible polyurethane membranes as occlusive dressing, which can provide moist and sterile environment over mild exudative wounds is considered in this work. In this regard, an epoxy-terminated polyurethane (EPU) prepolymer based on castor oil and glycidyltriethylammonium chloride (GTEAC) as a reactive bactericidal agent were synthesized. Polyurethane membranes were prepared through cocuring of EPU and different content of GTEAC with 1,4-butane diamine. The physical and mechanical properties, as well as cytocompatibility and antibacterial performance of prepared membranes were studied. Depending on their chemical formulations, the equilibrium water absorption and water vapor transmission rate values of the membranes were in ranges of 3-85% and 53-154g m(-2) day(-1), respectively. Therefore, these transparent membranes can maintain for a long period the moist environment over the wounds with low exudates. Detailed cytotoxicity analysis of samples against mouse L929 fibroblast and MCA-3D keratinocyte cells showed good level of cytocompatibility of membranes after purification via extraction of residual unreacted GTEAC moieties. The antibacterial activity of the membranes against Escherichia coli and Staphylococcus aureus bacteria was also studied. The membrane containing 50% GTEAC exhibited an effective antibacterial activity, while showed acceptable cytocompatibility and therefore, can be applied as an antibacterial occlusive wound dressing. PMID:23606508

  18. Relationship between retinal vascular occlusions and incident cerebrovascular diseases: A systematic review and meta-analysis.

    PubMed

    Zhou, Yue; Zhu, Wengen; Wang, Changyun

    2016-06-01

    Several studies investigating the role of retinal vascular occlusions, on cerebrovascular diseases (CVD) have been reported, but the results are still inconsistent. We therefore sought to evaluate the relationship between retinal vascular occlusions and CVD.We systematically searched the Cochrane Library, PubMed, and ScienceDirect databases through January 31, 2016 for studies evaluating the effect of retinal vascular occlusions on the risk of CVD. Data were abstracted using predefined criteria, and then pooled by RevMan 5.3 software.A total of 9 retrospective studies were included in this meta-analysis. When compared with individuals without retinal vascular occlusions, both individuals with retinal artery occlusion (RAO) (odds ratio [OR] = 2.01, 95% confidence interval [CI]: 1.21-3.34; P = 0.005) and individuals with retinal vein occlusion (RVO) (OR = 1.37, 95% CI: 1.24-1.50; P < 0.00001) had higher risks of developing CVD. Additionally, both individuals with central retinal artery occlusion (CRAO) (OR = 2.00, 95% CI: 1.12-3.56; P = 0.02) and branch retinal artery occlusion (BRAO) (OR = 1.60, 95% CI: 1.03-1.48; P = 0.04) were significantly associated with increased risk of CVD.Published literatures support both RVO and RAO are associated with increased risks of CVD. Further prospective studies are needed to confirm these findings. PMID:27368050

  19. Sex Differences in Infants' Mapping of Complex Occlusion Sequences: Further Evidence

    ERIC Educational Resources Information Center

    Wilcox, Teresa

    2007-01-01

    Recently, infant researchers have reported sex differences in infants' capacity to map their representation of an occlusion sequence onto a subsequent no-occlusion display. The research reported here sought to identify the extent to which these sex differences are observed in event-mapping tasks and to identify the underlying basis for these…

  20. Object Individuation in Infancy: The Use of Featural Information in Reasoning about Occlusion Events.

    ERIC Educational Resources Information Center

    Wilcox, Teresa; Baillargeon, Renee

    1998-01-01

    Eight experiments involving 134 infants aged 7.5 to 11.5 months show that even the youngest give evidence that they use featural information to individuate objects in an occlusion event. When tested with an event-mapping task, even 9.5-month olds give evidence that they can use featural information to interpret an occlusion event as long as the…

  1. 40 CFR 180.1148 - Occlusion Bodies of the Granulosis Virus of Cydia pomenella; tolerance exemption.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Virus of Cydia pomenella; tolerance exemption. 180.1148 Section 180.1148 Protection of Environment... RESIDUES IN FOOD Exemptions From Tolerances § 180.1148 Occlusion Bodies of the Granulosis Virus of Cydia... of the microbial pest control agent Occlusion Bodies of the Granulosis Virus of Cydia...

  2. 40 CFR 180.1148 - Occlusion Bodies of the Granulosis Virus of Cydia pomenella; tolerance exemption.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Virus of Cydia pomenella; tolerance exemption. 180.1148 Section 180.1148 Protection of Environment... RESIDUES IN FOOD Exemptions From Tolerances § 180.1148 Occlusion Bodies of the Granulosis Virus of Cydia... of the microbial pest control agent Occlusion Bodies of the Granulosis Virus of Cydia...

  3. 40 CFR 180.1148 - Occlusion Bodies of the Granulosis Virus of Cydia pomenella; tolerance exemption.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Virus of Cydia pomenella; tolerance exemption. 180.1148 Section 180.1148 Protection of Environment... RESIDUES IN FOOD Exemptions From Tolerances § 180.1148 Occlusion Bodies of the Granulosis Virus of Cydia... of the microbial pest control agent Occlusion Bodies of the Granulosis Virus of Cydia...

  4. 40 CFR 180.1148 - Occlusion Bodies of the Granulosis Virus of Cydia pomenella; tolerance exemption.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Virus of Cydia pomenella; tolerance exemption. 180.1148 Section 180.1148 Protection of Environment... RESIDUES IN FOOD Exemptions From Tolerances § 180.1148 Occlusion Bodies of the Granulosis Virus of Cydia... of the microbial pest control agent Occlusion Bodies of the Granulosis Virus of Cydia...

  5. 40 CFR 180.1148 - Occlusion Bodies of the Granulosis Virus of Cydia pomenella; tolerance exemption.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Virus of Cydia pomenella; tolerance exemption. 180.1148 Section 180.1148 Protection of Environment... RESIDUES IN FOOD Exemptions From Tolerances § 180.1148 Occlusion Bodies of the Granulosis Virus of Cydia... of the microbial pest control agent Occlusion Bodies of the Granulosis Virus of Cydia...

  6. Short series of upper limb acute arterial occlusions in 4 different etiologies and review of literature.

    PubMed

    Coskun, Selcuk; Soylu, Lutfi; Coskun, Pınar Koksal; Bayazıt, Murat

    2013-12-01

    Upper limb acute arterial occlusions are uncommon, and when compared with lower limb occlusions, only a few cases have been reported. Although atrial fibrillation is the most common cause, many conditions may lead to ischemia. In this article, 8 cases of upper limb arterial ischemia due to 4 different etiologies were reported (7 brachial, 1 axillary), and the literature was reviewed. PMID:24055482

  7. Modified complete-arch impression technique for facilitating esthetic and biomechanical precision in complete-arch rehabilitation.

    PubMed

    Mizrahi, Basil

    2011-08-01

    Treating complex cases is clinically and technically challenging, yet highly rewarding to both patient and clinician when successfully completed. Precision in the fit of the restorations, the definitive occlusal scheme, and the esthetic result are the key elements to long-term success. Clinicians should aim to achieve the same level of precision when treating these cases as they do when treating simple cases; however, with the numerous stages and increased complexity involved comes the potential for errors to compound and magnify as treatment progresses. Areas particularly prone to difficulties are the making of a complete-arch impression and the ability to maintain patient comfort and eliminate unwanted dental emergencies throughout the time-consuming treatment. This report illustrates the techniques and concepts used to achieve esthetic and biomechanical precision when treating complex cases. Specific emphasis is placed on the importance of an accurate complete-arch impression technique, the detail of which is described in the article. PMID:21843229

  8. Endovascular recanalization of infrapopliteal occlusions in patients with critical limb ischemia

    PubMed Central

    Singh, Gagan D.; Armstrong, Ehrin J.; Yeo, Khung-Keong; Singh, Satinder; Westin, Gregory G.; Pevec, William C.; Dawson, David L.; Laird, John R.

    2014-01-01

    Background Endovascular therapies are increasingly used for treatment of critical limb ischemia (CLI). Infrapopliteal (IP) occlusions are common in CLI, and successful limb salvage may require restoration of arterial flow in the distribution of a chronically occluded vessel. We sought to describe the procedural characteristics and outcomes of patients with IP occlusions who underwent endovascular intervention for treatment of CLI. Methods All patients with IP interventions for treatment of CLI from 2006 to 2012 were included. Angiographic and procedural data were compared between patients who underwent intervention for IP occlusions vs IP stenosis. Restenosis was determined by Doppler ultrasound imaging. Limb salvage was the primary end point of the study. Additional end points included primary patency, primary assisted patency, secondary patency, occlusion crossing success, procedural success, and amputation-free survival. Results A total of 187 patients with CLI underwent interventions for 356 IP lesions, and 77 patients (41%) had interventions for an IP occlusion. Patients with an intervention for IP occlusion were more likely to have zero to one vessel runoff (83% vs 56%; P < .001) compared with interventions for stenosis. Compared with IP stenoses, IP occlusions were longer (118 ± 86 vs 73 ± 67 mm; P < .001) and had a smaller vessel diameter (2.5 ± 0.8 vs 2.7 ± 0.5 mm; P =.02). Wire crossing was achieved in 83% of IP occlusions, and the overall procedural success for IP occlusions was 79%. The overall 1-year limb salvage rate was 84%. Limb salvage was highest in the stenosis group, slightly lower in the successful occlusion group, and lowest in the failed occlusion group (92% vs 75% vs 58%, respectively; P = .02). Unsuccessfully treated IP occlusions were associated with a significantly higher likelihood of major amputation (hazard ratio, 5.79; 95% confidence interval, 1.89–17.7) and major amputation or death (hazard ratio, 2.69; 95% confidence interval

  9. Subclavian steal and rest pain in a case of brachiocephalic artery occlusion.

    PubMed

    Kapa, Suraj; Adams, Jonathon

    2008-01-01

    A patient with multiple vessel disease presented with symptoms of significant bilateral upper extremity pain and weakness that was more significant on the right side. On carotid duplex scanning, brachiocephalic artery occlusion with retrograde flow was noted through the right common carotid and right vertebral arteries at rest. Furthermore, 50% to 90% occlusion of the left internal carotid was noted. Filling of the right subclavian artery was noted to be through the right vertebral and right common carotid arteries. Unlike isolated subclavian steal syndrome, brachiocephalic artery occlusion induces significant hemodynamic alterations in extracranial arterial flow, which normally produces no symptoms at rest, but may produce symptoms with exercise. The occurrence of subclavian steal phenomenon in the presence of brachiocephalic occlusion is extremely rare. The present case is the first to report a patient presenting with bilateral upper extremity rest pain in the presence of brachiocephalic artery occlusive disease. PMID:22477423

  10. Measurement of mandibular movements in parafunctional patient using occlusal splint with Bragg gratings: pilot study

    NASA Astrophysics Data System (ADS)

    Franco, Ana Paula G. O.; Gebert, Andréa. O.; Souza, Mauren A.; Jeranoski, Lorena; Kalinowski, Hypolito J.; Abe, Ilda

    2016-05-01

    The aim of the study is to demonstrate the potential of the fibre Braggs grating (FBG) in the measurement of different jaw movements that are performed for patients with occlusal parafunction using occlusal splints. Two silicon plates each 2mm are used, the fibre optic sensor is positioned in the maxillary left first molar region above the point of contact with opposing tooth after pressing the first plate on the model. Then the second silicon plate is pressed. The device has a final thickness of 2 mm. The occlusal splint is installed in the mouth of the patient who underwent different movements on occlusal splint. The maximum frequency bite is monitored. The results demonstrate that the bite shows a difference between grinding and clenching movements. The curves behaviour patterns are presented in order to show these different comparisons. Therefore, it is concluded that the fibre Braggs grating consists in an efficient method for monitoring the mechanical behaviour bite of patients with occlusal splints.

  11. Early Venous Occlusion Detection in a Free Flap Using Real-time Laser Doppler Imaging

    PubMed Central

    Alkhashnam, Héba; Sarfati, Benjamin; Kolb, Frédéric

    2013-01-01

    Summary: Early detection of venous occlusion in free flaps is particularly difficult to identify, and its duration is known to be directly proportional to flap mortality. Here, we report a case of deep inferior epigastric perforator based breast reconstruction in which the intraoperative use of a perfusion camera enabled identifying a venous occlusion based on microcirculatory pulsation dynamics in real time. The sensitivity of our proposed method suggests that in certain cases in which the onset of venous occlusion begins in the operating room we can detect and treat occlusion before sending the patient to recovery. Further development of this technique will allow for earlier and more objective decision making with regard to venous occlusion detection in free tissue transfer. PMID:25289200

  12. Lipid membranes for membrane proteins.

    PubMed

    Kukol, Andreas

    2015-01-01

    The molecular dynamics (MD) simulation of membrane proteins requires the setup of an accurate representation of lipid bilayers. This chapter describes the setup of a lipid bilayer system from scratch using generally available tools, starting with a definition of the lipid molecule POPE, generation of a lipid bilayer, energy minimization, MD simulation, and data analysis. The data analysis includes the calculation of area and volume per lipid, deuterium order parameters, self-diffusion constant, and the electron density profile. PMID:25330959

  13. Using occlusal wear information and finite element analysis to investigate stress distributions in human molars

    PubMed Central

    Benazzi, Stefano; Kullmer, Ottmar; Grosse, Ian R; Weber, Gerhard W

    2011-01-01

    Simulations based on finite element analysis (FEA) have attracted increasing interest in dentistry and dental anthropology for evaluating the stress and strain distribution in teeth under occlusal loading conditions. Nonetheless, FEA is usually applied without considering changes in contacts between antagonistic teeth during the occlusal power stroke. In this contribution we show how occlusal information can be used to investigate the stress distribution with 3D FEA in lower first molars (M1). The antagonistic crowns M1 and P2–M1 of two dried modern human skulls were scanned by μCT in maximum intercuspation (centric occlusion) contact. A virtual analysis of the occlusal power stroke between M1 and P2–M1 was carried out in the Occlusal Fingerprint Analyser (OFA) software, and the occlusal trajectory path was recorded, while contact areas per time-step were visualized and quantified. Stress distribution of the M1 in selected occlusal stages were analyzed in strand7, considering occlusal information taken from OFA results for individual loading direction and loading area. Our FEA results show that the stress pattern changes considerably during the power stroke, suggesting that wear facets have a crucial influence on the distribution of stress on the whole tooth. Grooves and fissures on the occlusal surface are seen as critical locations, as tensile stresses are concentrated at these features. Properly accounting for the power stroke kinematics of occluding teeth results in quite different results (less tensile stresses in the crown) than usual loading scenarios based on parallel forces to the long axis of the tooth. This leads to the conclusion that functional studies considering kinematics of teeth are important to understand biomechanics and interpret morphological adaptation of teeth. PMID:21615398

  14. Central Sensitization and MAPKs are Involved in Occlusal Interference-Induced Facial Pain in Rats

    PubMed Central

    Cao, Ye; Li, Kai; Fu, Kai-Yuan; Xie, Qiu-Fei; Chiang, Chen-Yu; Sessle, Barry J.

    2013-01-01

    We previously developed a rat dental occlusal interference model of facial pain that was produced by bonding a crown onto the right maxillary first molar and was reflected in sustained facial hypersensitivity that was suggestive of the involvement of central sensitization mechanisms. The aim of the present study was to investigate potential central mechanisms involved in the occlusal interference-induced facial hypersensitivity. A combination of behavioral, immunohistochemical, Western blot and electrophysiological recording procedures was used in 98 male adult Sprague-Dawley rats that either received the occlusal interference or were sham-operated or naive rats. Immunohistochemically labeled astrocytes and microglia in trigeminal subnucleus caudalis (Vc) showed morphological changes indicative of astrocyte and microglial activation after the occlusal interference. Prolonged upregulation of p38 MAPK and ERK was also documented in Vc after placement of the occlusal interference, and was expressed in both neurons and glial cells at time points when rats showed peak mechanical facial hypersensitivity. The i.t. administration of the p38 MAPK inhibitor SB203580 to the medulla significantly inhibited the occlusal interference-induced hypersensitivity, and the ERK inhibitor PD98059 produced an even stronger effect. Central sensitization of functionally identified Vc nociceptive neurons following placement of the occlusal interference was also documented by extracellular electrophysiological recordings, and i.t. administration of PD98059 could reverse the neuronal central sensitization. These novel findings suggest that central mechanisms including central sensitization of trigeminal nociceptive neurons and non-neuronal processes involving MAPKs play significant roles in the production of occlusal interference-induced facial pain. Perspective Central mechanisms including trigeminal nociceptive neuronal sensitization, non-neuronal processes involving glial activation and

  15. Collateral circulation in ferrets (Mustela putorius) during temporary occlusion of the caudal vena cava.

    PubMed

    Calicchio, Kristina W; Bennett, R Avery; Laraio, Leonard C; Weisse, Chick; Zwingenberger, Allison L; Rosenthal, Karen L; Johnston, Matthew S; Campbell, Vicki L; Solomon, Jeffrey A

    2016-05-01

    OBJECTIVE To determine whether extent of collateral circulation would change during temporary occlusion of the caudal vena cava (CVC) in ferrets (Mustela putorius), a pressure change would occur caudal to the occlusion, and differences would exist between the sexes with respect to those changes. ANIMALS 8 adult ferrets (4 castrated males and 4 spayed females). PROCEDURES Ferrets were anesthetized. A balloon occlusion catheter was introduced through a jugular vein, passed into the CVC by use of fluoroscopy, positioned cranial to the right renal vein, and inflated for 20 minutes. Venography was performed 5 and 15 minutes after occlusion. Pressure in the CVC caudal to the occlusion was measured continuously. A CBC, plasma biochemical analysis, and urinalysis were performed immediately after the procedure and 2 or 3 days later. RESULTS All 8 ferrets survived the procedure; no differences were apparent between the sexes. Vessels providing collateral circulation were identified in all ferrets, indicating blood flow to the paravertebral venous plexus. Complications observed prior to occlusion included atrial and ventricular premature contractions. Complications after occlusion included bradycardia, seizures, and extravasation of contrast medium. Mean baseline CVC pressure was 5.4 cm H2O. During occlusion, 6 ferrets had a moderate increase in CVC pressure (mean, 24.3 cm H2O) and 2 ferrets had a marked increase in CVC pressure to > 55.0 cm H2O. CONCLUSIONS AND CLINICAL RELEVANCE Caval occlusion for 20 minutes was performed in healthy ferrets with minimal adverse effects noted within the follow-up period and no apparent differences between sexes. The CVC pressure during occlusion may be prognostic in ferrets undergoing surgical ligation of the CVC, which commonly occurs during adrenal tumor resection. PMID:27111022

  16. Effect of prosthodontic planning on lateral occlusion scheme: a comparison between conventional and digital planning

    PubMed Central

    ABDUO, Jaafar; BENNAMOUN, Mohammed; TENNANT, Marc; McGEACHIE, John

    2015-01-01

    Recently, digital wax-up is proposed as a tool to aid prosthodontic planning. However, there are no data about the effect of prosthodontic planning on lateral occlusion scheme. Objective : This study aims to evaluate the impact of conventional and digital prosthodontic planning on lateral occlusion scheme. Material and Methods : Dental models of 10 patients were collected. All models had Angle Class I occlusion and were undergoing prosthodontic treatment that would influence the lateral occlusion scheme. Each set of models had received both conventional wax-up and digital wax-up. In relation to the lateral occlusion scheme, the following variables were evaluated: the prevalence of the different lateral occlusion scheme, number of contacting teeth and percentage of each contacting tooth. Four excursive positions on the working side were included: 0.5, 1.0, 2.0 and 3.0 mm from the maximal intercuspation position. Results : The lateral occlusion scheme of the two wax-up models was subjected to alterations following excursion. There was a tendency for the prevalence of canine-guided occlusion to increase and for the prevalence of group function occlusion to decrease with increasing excursion. The number of contacting teeth was decreasing with the increasing magnitude of excursion. For the 0.5 mm and 1.0 mm positions, the two wax-ups had significantly greater contacts than the pre-treatment models, while at the 2.0 mm and 3.0 mm positions, all the models were similar. For all models, canines were the most commonly contacting teeth, followed by the teeth adjacent to them. No difference was observed between the two wax-ups in relation to the number of contacting teeth. Conclusion : Although the prosthodontic planning had influenced the pattern of the lateral occlusion scheme and contacts, there was no difference between the conventional and digital prosthodontic planning. PMID:26018312

  17. Plasmacytic Aortitis with Occlusion of the Right Coronary Artery.

    PubMed

    Zambetti, Benjamin R; Garrett, Edward

    2016-01-01

    BACKGROUND Inflammation of the aortic wall, known as aortitis, is a rare clinical entity which is frequently asymptomatic, or identified when the patient presents with an aortic aneurysm or dissection. It is most often caused by infection or autoimmune vasculitides such as giant cell or Takayasu's arteritis. CASE REPORT The case presented is that of a 55-year-old man with symptomatic occlusion of the right coronary artery caused by a plasmacytic aortitis suggestive of IgG4 disease, which was successfully treated with coronary artery bypass grafting and an ascending aortic graft. CONCLUSIONS A review of the current literature emphasizes how poorly the etiology and natural history of plasmacytic aortitis is understood. PMID:27471062

  18. Plasmacytic Aortitis with Occlusion of the Right Coronary Artery

    PubMed Central

    Zambetti, Benjamin R.; Garrett, Edward

    2016-01-01

    Patient: Male, 55 Final Diagnosis: Plasmacytic aortitis Symptoms: Dizziness • nausea Medication: — Clinical Procedure: — Specialty: Surgery Objective: Unusual clinical course Background: Inflammation of the aortic wall, known as aortitis, is a rare clinical entity which is frequently asymptomatic, or identified when the patient presents with an aortic aneurysm or dissection. It is most often caused by infection or autoimmune vasculitides such as giant cell or Takayasu’s arteritis. Case Report: The case presented is that of a 55-year-old man with symptomatic occlusion of the right coronary artery caused by a plasmacytic aortitis suggestive of IgG4 disease, which was successfully treated with coronary artery bypass grafting and an ascending aortic graft. Conclusions: A review of the current literature emphasizes how poorly the etiology and natural history of plasmacytic aortitis is understood. PMID:27471062

  19. Pedestrian Counting with Occlusion Handling Using Stereo Thermal Cameras.

    PubMed

    Kristoffersen, Miklas S; Dueholm, Jacob V; Gade, Rikke; Moeslund, Thomas B

    2016-01-01

    The number of pedestrians walking the streets or gathered in public spaces is a valuable piece of information for shop owners, city governments, event organizers and many others. However, automatic counting that takes place day and night is challenging due to changing lighting conditions and the complexity of scenes with many people occluding one another. To address these challenges, this paper introduces the use of a stereo thermal camera setup for pedestrian counting. We investigate the reconstruction of 3D points in a pedestrian street with two thermal cameras and propose an algorithm for pedestrian counting based on clustering and tracking of the 3D point clouds. The method is tested on two five-minute video sequences captured at a public event with a moderate density of pedestrians and heavy occlusions. The counting performance is compared to the manually annotated ground truth and shows success rates of 95.4% and 99.1% for the two sequences. PMID:26742047

  20. Retrograde crossing for chronic total occlusion lesions: the Japanese way.

    PubMed

    Takano, Masamichi; Mizuno, Kyoichi

    2008-01-01

    Percutaneous coronary intervention (PCI) for chronic total occlusion (CTO) lesions remains one of the major challenges in the field of interventional cardiology. Crossing guidewires through the CTO lesions has been conventionally performed from the proximal arteries to the lesions as an antegrade approach. To date, a retrograde approach, to penetrate PCI devices including guidewires and balloons into the distal end of CTO lesions via collateral vessels or coronary artery bypass grafts, has been attempted in order to achieve procedural success. With introduction of the retrograde approach for treatments of CTO lesions, several kinds of devices, techniques, and strategies have been developed. Although the techniques and strategies for the retrograde approach have not been worldwide accepted to interventional cardiologists, we introduce a way to obtain recanalization of the CTO lesions using the retrograde approach in this article. PMID:19276488

  1. Combined branch retinal vein and artery occlusion in toxoplasmosis.

    PubMed

    Aggio, Fabio Bom; Novelli, Fernando José de; Rosa, Evandro Luis; Nobrega, Mário Junqueira

    2016-01-01

    A 22-year-old man complained of low visual acuity and pain in his left eye for five days. His ophthalmological examination revealed 2+ anterior chamber reaction and a white, poorly defined retinal lesion at the proximal portion of the inferotemporal vascular arcade. There were retinal hemorrhages in the inferotemporal region extending to the retinal periphery. In addition, venous dilation, increased tortuosity, and ischemic retinal whitening along the inferotemporal vascular arcade were also observed. A proper systemic work-up was performed, and the patient was diagnosed with ocular toxoplasmosis. He was treated with an anti-toxoplasma medication, and his condition slowly improved. Inferior macular inner and middle retinal atrophy could be observed on optical coherence tomography as a sequela of ischemic injury. To our knowledge, this is the first report of combined retinal branch vein and artery occlusion in toxoplasmosis resulting in a striking and unusual macular appearance. PMID:27463632

  2. Pedestrian Counting with Occlusion Handling Using Stereo Thermal Cameras

    PubMed Central

    Kristoffersen, Miklas S.; Dueholm, Jacob V.; Gade, Rikke; Moeslund, Thomas B.

    2016-01-01

    The number of pedestrians walking the streets or gathered in public spaces is a valuable piece of information for shop owners, city governments, event organizers and many others. However, automatic counting that takes place day and night is challenging due to changing lighting conditions and the complexity of scenes with many people occluding one another. To address these challenges, this paper introduces the use of a stereo thermal camera setup for pedestrian counting. We investigate the reconstruction of 3D points in a pedestrian street with two thermal cameras and propose an algorithm for pedestrian counting based on clustering and tracking of the 3D point clouds. The method is tested on two five-minute video sequences captured at a public event with a moderate density of pedestrians and heavy occlusions. The counting performance is compared to the manually annotated ground truth and shows success rates of 95.4% and 99.1% for the two sequences. PMID:26742047

  3. Anterior segment ischemia secondary to carotid occlusive disease.

    PubMed

    Mills, R P

    1989-09-01

    The ischemic signs of carotid occlusive disease in the anterior segment can be summarized as follows: vasodilation in the conjunctiva, episclera, and iris; neovascularization in the iris and the anterior chamber angle with consequent neovascular glaucoma, with or without elevation of intraocular pressure; and noninflammatory uveitis with corneal edema, keratitic precipitates, flare and cells in the anterior chamber, and late development of cataract. A questionnaire was sent to neuro-ophthalmology and glaucoma specialists regarding their perceptions of this condition. On average, approximately 1 case per specialist per year was seen. One third of the respondents had seen significant ocular pressure increase in patients with rubeosis following successful vascular surgery. Most felt that panretinal photocoagulation, though not as effective as in diabetic rubeosis, did cause regression of iris and angle neovascularization. The visual prognosis following all types of treatment was not good and was insufficient to justify a clear recommendation about the advisability of aggressive management of this condition. PMID:2529282

  4. Myocardial viability in coronary artery chronic total occlusion.

    PubMed

    Vefali, Huseng; Manda, Yugandhar; Shirani, Jamshid

    2015-01-01

    Coronary artery chronic total occlusion (CTO) has rapidly become a popular target of percutaneous coronary intervention (PCI). Technical and technological advances required for approaching these anatomically complex and challenging lesions have progressed at an extraordinary pace and have led to amazing success rates. Patient selection, however, has primarily focused on patient symptoms, lesion characteristics, as well as the state of collateral circulation. Multiple national and international registries have been established to follow the progress of percutaneous CTO recanalization and have provided valuable information. Concern, however, exists that this challenging procedure will become the "standard of care" before its effectiveness and appropriateness is tested in prospective controlled trials. This manuscript reviews the current state of patient selection and the need for careful assessment of the presence and extent of myocardial viability prior to lengthy, resource-intensive, and potentially high-risk procedures. PMID:25413581

  5. Longitudinal relationship between incisal occlusion and incisal tooth wear.

    PubMed

    Silness, J; Johannessen, G; Røynstrand, T

    1993-02-01

    The purpose of the study was to evaluate the longitudinal relationship between incisal wear of central incisors and the size of vertical overbite (OB) and horizontal overjet (OJ). Stone casts of 51 subjects were used for the determinations. Casts were obtained when the subjects were 15 and 27 years old. Statistical analysis was performed with the t test for paired samples, the chi-square test of association. Pearson's product moment correlation coefficient, and Spearman's rank correlation coefficient. Both overbite and overjet diminished after 12 years, and incisal wear increased. It was concluded that increase in age, incisal wear, vertical overbite and incisal occlusion (OB/OJ) are clinical predictors of wear of maxillary and mandibular central incisors in adolescents. PMID:8451919

  6. Omniphobic Membrane for Robust Membrane Distillation

    SciTech Connect

    Lin, SH; Nejati, S; Boo, C; Hu, YX; Osuji, CO; Ehmelech, M

    2014-11-01

    In this work, we fabricate an omniphobic microporous membrane for membrane distillation (MD) by modifying a hydrophilic glass fiber membrane with silica nanoparticles followed by surface fluorination and polymer coating. The modified glass fiber membrane exhibits an anti-wetting property not only against water but also against low surface tension organic solvents that easily wet a hydrophobic polytetrafluoroethylene (PTFE) membrane that is commonly used in MD applications. By comparing the performance of the PTFE and omniphobic membranes in direct contact MD experiments in the presence of a surfactant (sodium dodecyl sulfate, SDS), we show that SDS wets the hydrophobic PTFE membrane but not the omniphobic membrane. Our results suggest that omniphobic membranes are critical for MD applications with feed waters containing surface active species, such as oil and gas produced water, to prevent membrane pore wetting.

  7. Subintimal Angioplasty for Peripheral Arterial Occlusive Disease: A Systematic Review

    SciTech Connect

    Met, Rosemarie Lienden, Krijn P. Van; Koelemay, Mark J. W.; Bipat, Shandra; Legemate, Dink A.; Reekers, Jim A.

    2008-07-15

    The objective of this study was to summarize outcomes of subintimal angioplasty (SA) for peripheral arterial occlusive disease. The Cochrane Library, Medline and Embase databases were searched to perform a systematic review of the literature from 1966 through May 2007 on outcomes of SA for peripheral arterial occlusive disease of the infrainguinal vessels. The keywords 'percutaneous intentional extraluminal revascularization,' 'subintimal angioplasty,' 'peripheral arterial disease,' 'femoral artery,' 'popliteal artery,' and 'tibial artery' were used. Assessment of study quality was done using a form based on a checklist of the Dutch Cochrane Centre. The recorded outcomes were technical and clinical success, primary (assisted) patency, limb salvage, complications, and survival, in relation to the clinical grade of disease (intermittent claudication or critical limb ischemia [CLI] or mixed) and location of lesion (femoropopliteal, crural, or mixed). Twenty-three cohort studies including a total of 1549 patients (range, 27 to 148) were included in this review. Methodological and reporting quality were moderate, e.g., there was selection bias and reporting was not done according to the reporting standards. These and significant clinical heterogeneity obstructed a meta-analysis. Reports about length of the lesion and TASC classification were too various to summarize or were not mentioned at all. The technical success rates varied between 80% and 90%, with lower rates for crural lesions compared with femoral lesions. Complication rates ranged between 8% and 17% and most complications were minor. After 1 year, clinical success was between 50% and 70%, primary patency was around 50% and limb salvage varied from 80% to 90%. In conclusion, taking into account the methodological shortcomings of the included studies, SA can play an important role in the treatment of peripheral arterial disease, especially in the case of critical limb ischemia. Despite the moderate patency

  8. Different Imaging Strategies in Patients With Possible Basilar Artery Occlusion

    PubMed Central

    Beyer, Sebastian E.; Hunink, Myriam G.; Schöberl, Florian; von Baumgarten, Louisa; Petersen, Steffen E.; Dichgans, Martin; Janssen, Hendrik; Ertl-Wagner, Birgit; Reiser, Maximilian F.

    2015-01-01

    Background and Purpose— This study evaluated the cost-effectiveness of different noninvasive imaging strategies in patients with possible basilar artery occlusion. Methods— A Markov decision analytic model was used to evaluate long-term outcomes resulting from strategies using computed tomographic angiography (CTA), magnetic resonance imaging, nonenhanced CT, or duplex ultrasound with intravenous (IV) thrombolysis being administered after positive findings. The analysis was performed from the societal perspective based on US recommendations. Input parameters were derived from the literature. Costs were obtained from United States costing sources and published literature. Outcomes were lifetime costs, quality-adjusted life-years (QALYs), incremental cost-effectiveness ratios, and net monetary benefits, with a willingness-to-pay threshold of $80 000 per QALY. The strategy with the highest net monetary benefit was considered the most cost-effective. Extensive deterministic and probabilistic sensitivity analyses were performed to explore the effect of varying parameter values. Results— In the reference case analysis, CTA dominated all other imaging strategies. CTA yielded 0.02 QALYs more than magnetic resonance imaging and 0.04 QALYs more than duplex ultrasound followed by CTA. At a willingness-to-pay threshold of $80 000 per QALY, CTA yielded the highest net monetary benefits. The probability that CTA is cost-effective was 96% at a willingness-to-pay threshold of $80 000/QALY. Sensitivity analyses showed that duplex ultrasound was cost-effective only for a prior probability of ≤0.02 and that these results were only minimally influenced by duplex ultrasound sensitivity and specificity. Nonenhanced CT and magnetic resonance imaging never became the most cost-effective strategy. Conclusions— Our results suggest that CTA in patients with possible basilar artery occlusion is cost-effective. PMID:26022634

  9. Intestinal disaccharidase activity following pancreatic duct occlusion in the rat.

    PubMed

    Hauer-Jensen, M; Christensen, K; Wilson, H D; Schedl, H P

    1987-01-01

    The influence of pancreatic secretions on growth and brush-border enzyme activity, throughout the entire small intestine, was examined in the rat. Pancreatic secretions were excluded from the gut lumen by stapling the pancreatic ducts, without interruption of bile flow. The entire small intestine was studied as four segments; the duodenum and three distal segments of equal length. Weight of intestine and mucosa, and mucosal sucrase, isomaltase, lactase, and alkaline phosphatase activity were measured 10-15 days following pancreatic duct occlusion, or sham-operation. The duodenum of pancreatic duct-occluded animals exhibited significant hypertrophy. In general, specific and total disaccharidase activities were greater in duct-occluded animals than in controls throughout the intestine. The increase was more pronounced in distal than in proximal segments. The sucrase/isomaltase ratio was significantly greater in pancreatic duct-occluded animals than in controls in the two distal segments. Alkaline phosphatase activity was not affected by pancreatic duct occlusion. The greater relative increase of disaccharidase activities and sucrase/isomaltase activity ratios in the distal segments of duct-occluded animals, indicates a more important regulatory role of pancreatic enzymes in the distal small intestine. It is concluded that regulation of intestinal brush-border enzyme activity by pancreatic secretion is selective for enzyme and site as follows: disaccharidases, but not alkaline phosphatase, are regulated; the sucrase subunit of the sucrase/isomaltase complex is most sensitive to regulation, while lactase is least sensitive; and the regulatory effect on disaccharidases is greater in distal than in proximal intestine. PMID:3114740

  10. An in-vitro study of the effect of hydrocolloid patch occlusion on the penetration of triamcinolone acetonide through skin in man.

    PubMed

    Ladenheim, D; Martin, G P; Marriott, C; Hollingsbee, D A; Brown, M B

    1996-08-01

    The aim of this study was to evaluate the effect of occlusion using hydrocolloid-containing patches on in-vitro triamcinolone acetonide (TACA) penetration of the epidermis while monitoring the uptake of water by the patches as a result of transepidermal water loss. The hydrocolloid patches were a laminate of a pressure-sensitive hydrophobic adhesive (containing a dispersion of 39% of either pectin or carmellose sodium) and a polyethylene film. The diffusion of a representative corticosteroid (TACA) through isolated epidermal sheet was shown to depend on the site from which the skin was removed. The two patch-types exhibited markedly different hydration rates when applied to the membranes. For example, after 96 h the carmellose sodium patch showed ten times the weight increase of the pectin patch. Epidermal diffusion rates were, however, similar, both showing a 3-4-fold enhancement over unoccluded conditions. The increase in TACA diffusion with the patches can be explained by the increase in skin hydration that occurs during occlusion. Despite the large differences in transepidermal water transfer through the epidermal membranes with the two types of hydrocolloid patch, however, this level of stratum corneum hydration was apparently similar. As the rate of diffusion was also independent of hydrocolloid patch component, it seems possible that the hydrophobic component of the patch matrix may also influence the level of skin hydration and consequent drug diffusion. PMID:8887729

  11. Composite membranes and methods for making same

    DOEpatents

    Routkevitch, Dmitri; Polyakov, Oleg G

    2012-07-03

    Composite membranes that are adapted for separation, purification, filtration, analysis, reaction and sensing. The composite membranes can include a porous support structure having elongate pore channels extending through the support structure. The composite membrane also includes an active layer comprising an active layer material, where the active layer material is completely disposed within the pore channels between the surfaces of the support structure. The active layer is intimately integrated within the support structure, thus enabling great robustness, reliability, resistance to mechanical stress and thermal cycling, and high selectivity. Methods for the fabrication of composite membranes are also provided.

  12. A Single Visit Direct Technique to Provisionally Restore Occlusion for a Full-Mouth Rehabilitation: A Clinical Report.

    PubMed

    El-Kerdani, Tarek; Nimmo, Arthur

    2016-01-01

    Attrition of the dentition can negatively affect esthetics and function. When reconstructing patients with attrition who require restoration at increased occlusal vertical dimension (OVD), it is necessary to first evaluate the OVD using a removable interim prosthesis to ensure that the patient will tolerate the new position. The transition to fixed interim prostheses has to be carefully planned to achieve the desired OVD. One approach is to prepare all teeth in a single day and place full-arch interim prostheses; however, this can be tiring for the patient and prosthodontist. An alternative approach is to prepare one arch and place interim prostheses, while using composite resin in the opposing arch to maintain the newly established OVD. A diagnostic wax-up at the proposed OVD is completed and duplicated in stone. A vacuform matrix is loaded with composite resin and applied to the unprepared etched teeth of the opposing arch to restore form and occlusion until full contour interim prostheses are placed at a later visit. PMID:25659611

  13. The Effects of CO2 Laser with or without Nanohydroxyapatite Paste in the Occlusion of Dentinal Tubules

    PubMed Central

    Al-maliky, Mohammed Abbood; Mahmood, Ali Shukur; Al-karadaghi, Tamara Sardar; Kurzmann, Christoph; Laky, Markus; Franz, Alexander; Moritz, Andreas

    2014-01-01

    The aim of this study was to evaluate a new treatment modality for the occlusion of dentinal tubules (DTs) via the combination of 10.6 µm carbon dioxide (CO2) laser and nanoparticle hydroxyapatite paste (n-HAp). Forty-six sound human molars were used in the current experiment. Ten of the molars were used to assess the temperature elevation during lasing. Thirty were evaluated for dentinal permeability test, subdivided into 3 groups: the control group (C), laser only (L−), and laser plus n-HAp (L+). Six samples, two per group, were used for surface and cross section morphology, evaluated through scanning electron microscope (SEM). The temperature measurement results showed that the maximum temperature increase was 3.2°C. Morphologically groups (L−) and (L+) presented narrower DTs, and almost a complete occlusion of the dentinal tubules for group (L+) was found. The Kruskal-Wallis nonparametric test for permeability test data showed statistical differences between the groups (P < 0.05). For intergroup comparison all groups were statistically different from each other, with group (L+) showing significant less dye penetration than the control group. We concluded that CO2 laser in moderate power density combined with n-HAp seems to be a good treatment modality for reducing the permeability of dentin. PMID:25386616

  14. Dynamic tracheal occlusion improves lung morphometrics and function in the fetal lamb model of congenital diaphragmatic hernia

    PubMed Central

    Jelin, Eric B.; Etemadi, Mozziyar; Encinas, Jose; Schecter, Samuel C.; Chapin, Cheryl; Wu, Jianfeng; Guevara-Gallardo, Salvador; Nijagal, Amar; Gonzales, Kelly D.; Ferrier, William T.; Roy, Shuvo; Miniati, Doug

    2011-01-01

    Background Congenital diaphragmatic hernia (CDH) is associated with significant neonatal morbidity and mortality. Although prenatal complete tracheal occlusion (cTO) causes hypoplastic CDH lungs to enlarge, improved lung function has not been demonstrated. Furthermore, cTO interferes with the dynamic pressure change and fluid flow associated with fetal breathing. Purpose To assess a novel dynamic tracheal occlusion (dTO) device that preserves pressure changes and fluid flow. Methods In this pilot study, CDH was created in fetal lambs at 65 days gestational age (GA). At 110 days GA, a cTO device (n=3) or a dTO device (n=4) was placed in the fetal trachea. At 135 days GA, lambs were delivered and resuscitated. Unoperated lamb co-twins (n=5), sham thoracotomy lambs (n=2), and untreated CDH lambs (n=3) served as controls. Results Tracheal opening pressure, lung volume, lung fluid total protein, and phospholipid were significantly higher in the cTO group than in the dTO and unoperated control groups. Maximal oxygenation and lung compliance were significantly lower in the cTO group when compared to the unoperated control and dTO groups. Conclusion Preliminary results suggest that in the fetal lamb CDH model, dTO restores normal lung morphometrics and function, whereas cTO leads to enlarged but less functional lungs. PMID:21683214

  15. Sweeping Gas Membrane Desalination Using Commercial Hydrophobic Hollow Fiber Membranes

    SciTech Connect

    EVANS, LINDSEY; MILLER, JAMES E.

    2002-01-01

    Water shortages affect 88 developing countries that are home to half of the world's population. In these places, 80-90% of all diseases and 30% of all deaths result from poor water quality. Furthermore, over the next 25 years, the number of people affected by severe water shortages is expected to increase fourfold. Low cost methods of purifying freshwater, and desalting seawater are required to contend with this destabilizing trend. Membrane distillation (MD) is an emerging technology for separations that are traditionally accomplished via conventional distillation or reverse osmosis. As applied to desalination, MD involves the transport of water vapor from a saline solution through the pores of a hydrophobic membrane. In sweeping gas MD, a flowing gas stream is used to flush the water vapor from the permeate side of the membrane, thereby maintaining the vapor pressure gradient necessary for mass transfer. Since liquid does not penetrate the hydrophobic membrane, dissolved ions are completely rejected by the membrane. MD has a number of potential advantages over conventional desalination including low temperature and pressure operation, reduced membrane strength requirements, compact size, and 100% rejection of non-volatiles. The present work evaluated the suitability of commercially available technology for sweeping gas membrane desalination. Evaluations were conducted with Celgard Liqui-Cel{reg_sign} Extra-Flow 2.5X8 membrane contactors with X-30 and X-40 hydrophobic hollow fiber membranes. Our results show that sweeping gas membrane desalination systems are capable of producing low total dissolved solids (TDS) water, typically 10 ppm or less, from seawater, using low grade heat. However, there are several barriers that currently prevent sweeping gas MD from being a viable desalination technology. The primary problem is that large air flows are required to achieve significant water yields, and the costs associated with transporting this air are prohibitive. To

  16. Intrabronchial Infusion of Autologous Blood Plus Thrombin for Intractable Pneumothorax After Bronchial Occlusion Using Silicon Spigots

    PubMed Central

    Nakahara, Yasuharu; Kawamura, Tetsuji; Sasaki, Shin; Tsukamoto, Hiroaki; Mochiduki, Yoshiro

    2016-01-01

    Background: Bronchial occlusion therapy using silicon spigots is effective for intractable pneumothorax. However, sometimes the pneumothorax is refractory to bronchial occlusion because of collateral ventilation. For such difficult pneumothoraces, we attempted an intrabronchial infusion of autologous blood plus thrombin to control collateral ventilation and stop air leaks. Methods: We performed bronchial occlusions using silicon spigots in patients with spontaneous pneumothorax secondary to emphysema and refractory to chest drainage, but which was inoperable owing to each patient’s poor surgical candidacy and poor overall health condition. When bronchial occlusion proved ineffective, we undertook intrabronchial infusion of autologous blood plus thrombin, 2 to 4 days after bronchial occlusion. A catheter was inserted into the subpleural area, through a gap between the silicon spigot and the bronchial wall, using a flexible bronchoscope under fluoroscopic guidance. Autologous blood, followed by a thrombin solution, was infused using the catheter. We repeated the same infusion a total of 4 to 6 times while changing the target bronchi. All interventions were performed under local anesthesia. Results: The subjects were 9 men, aged from 61 to 88 years, with smoking histories. Three patients also had interstitial pneumonia, and 6 patients had undergone pleurodesis in vain before bronchial occlusion. For 4of the 9 patients, autologous blood plus thrombin infusions successfully stopped air leaks, and in 3 patients, intrabronchial infusions and pleurodesis halted leaks altogether. Conclusion: Intrabronchial infusion of autologous blood plus thrombin was effective for intractable pneumothoraces that could not be clinically managed, even by bronchial occlusion using silicon spigots. PMID:27454474

  17. GORA: a scoring system for the quantification of risk of graft occlusion.

    PubMed

    Copeland, G P; Edwards, P; Wilcox, A; Wake, P N; Harris, P L

    1994-03-01

    Auditing the outcome from vascular surgery with regard to graft occlusion is made difficult by variations in the type of surgery performed and the case mix. These difficulties are compounded when attempting to compare units. In the present study we have attempted to develop a scoring system to predict the risk of graft occlusion, and thus compensate for these variables. Prospectively collected data from 214 consecutive patients undergoing vascular reconstructive surgery (233 arterial grafts) were analysed. Graft occlusion occurred in 82 patients (35.2%). Using a multivariate linear regression analysis of these data a five-factor, five-grade scoring system has been devised (GORA: Graft Occlusive Risk Assessment). Logistic regression analysis of the observed risk of occlusion with this derived score produced the following relationship between the odds ratio of occlusive risk and GORA score: (logeR/1 - R = (0.229 x score) - 4.165). The score was then validated in a different group of 186 patients (196 arterial grafts). In both groups the score was found to predict accurately the risk of graft occlusion (P < 0.001). There was no significant difference in the receiver operating characteristic curves between the estimation and validation groups. PMID:8154808

  18. Comparison of NIRS, laser Doppler flowmetry, photoplethysmography, and pulse oximetry during vascular occlusion challenges.

    PubMed

    Abay, T Y; Kyriacou, P A

    2016-04-01

    Monitoring changes in blood volume, blood flow, and oxygenation in tissues is of vital importance in fields such as reconstructive surgery and trauma medicine. Near infrared spectroscopy (NIRS), laser Doppler (LDF) flowmetry, photoplethysmography (PPG), and pulse oximetry (PO) contribute to such fields due to their safe and noninvasive nature. However, the techniques have been rarely investigated simultaneously or altogether. The aim of this study was to investigate all the techniques simultaneously on healthy subjects during vascular occlusion challenges. Sensors were attached on the forearm (NIRS and LDF) and fingers (PPG and PO) of 19 healthy volunteers. Different degrees of vascular occlusion were induced by inflating a pressure cuff on the upper arm. The responses of tissue oxygenation index (NIRS), tissue haemoglobin index (NIRS), flux (LDF), perfusion index (PPG), and arterial oxygen saturation (PO) have been recorded and analyzed. Moreover, the optical densities were calculated from slow varying dc PPG, in order to distinguish changes in venous blood volumes. The indexes showed significant changes (p  <  0.05) in almost all occlusions, either venous or over-systolic occlusions. However, differentiation between venous and arterial occlusion by LDF may be challenging and the perfusion index (PI) may not be adequate to indicate venous occlusions. Optical densities may be an additional tool to detect venous occlusions by PPG. PMID:26963349

  19. Occlusal enamel complexity in middle miocene to holocene equids (Equidae: Perissodactyla) of North America.

    PubMed

    Famoso, Nicholas A; Davis, Edward Byrd

    2014-01-01

    Four groups of equids, "Anchitheriinae," Merychippine-grade Equinae, Hipparionini, and Equini, coexisted in the middle Miocene, but only the Equini remains after 16 Myr of evolution and extinction. Each group is distinct in its occlusal enamel pattern. These patterns have been compared qualitatively but rarely quantitatively. The processes influencing the evolution of these occlusal patterns have not been thoroughly investigated with respect to phylogeny, tooth position, and climate through geologic time. We investigated Occlusal Enamel Index, a quantitative method for the analysis of the complexity of occlusal patterns. We used analyses of variance and an analysis of co-variance to test whether equid teeth increase resistive cutting area for food processing during mastication, as expressed in occlusal enamel complexity, in response to increased abrasion in their diet. Results suggest that occlusal enamel complexity was influenced by climate, phylogeny, and tooth position through time. Occlusal enamel complexity in middle Miocene to Modern horses increased as the animals experienced increased tooth abrasion and a cooling climate. PMID:24587267

  20. Occlusal Enamel Complexity in Middle Miocene to Holocene Equids (Equidae: Perissodactyla) of North America

    PubMed Central

    Famoso, Nicholas A.; Davis, Edward Byrd

    2014-01-01

    Four groups of equids, “Anchitheriinae,” Merychippine-grade Equinae, Hipparionini, and Equini, coexisted in the middle Miocene, but only the Equini remains after 16 Myr of evolution and extinction. Each group is distinct in its occlusal enamel pattern. These patterns have been compared qualitatively but rarely quantitatively. The processes influencing the evolution of these occlusal patterns have not been thoroughly investigated with respect to phylogeny, tooth position, and climate through geologic time. We investigated Occlusal Enamel Index, a quantitative method for the analysis of the complexity of occlusal patterns. We used analyses of variance and an analysis of co-variance to test whether equid teeth increase resistive cutting area for food processing during mastication, as expressed in occlusal enamel complexity, in response to increased abrasion in their diet. Results suggest that occlusal enamel complexity was influenced by climate, phylogeny, and tooth position through time. Occlusal enamel complexity in middle Miocene to Modern horses increased as the animals experienced increased tooth abrasion and a cooling climate. PMID:24587267