Sample records for condenser cooling systems

  1. Preoperational test report, recirculation condenser cooling systems

    SciTech Connect

    Clifton, F.T.

    1997-11-04

    This represents a preoperational test report for Recirculation Condenser Systems, Project W-030. Project W-030 provides a ventilation upgrade for the four Aging Waste Facility tanks. The four system provide condenser cooling water for vapor space cooling of tanks AY1O1, AY102, AZ1O1, AZ102. Each system consists of a valved piping loop, a pair of redundant recirculation pumps, a closed-loop evaporative cooling tower, and supporting instrumentation; equipment is located outside the farm on concrete slabs. Piping is routed to the each ventilation condenser inside the farm via below-grade concrete trenches. The tests verify correct system operation and correct indications displayed by the central Monitor and Control System.

  2. Preoperational test report, primary ventilation condenser cooling system

    SciTech Connect

    Clifton, F.T.

    1997-10-29

    This represents the preoperational test report for the Primary Ventilation Condenser Cooling System, Project W-030. Project W-030 provides a ventilation upgrade for the four Aging Waste Facility tanks. The system uses a closed chilled water piping loop to provide offgas effluent cooling for tanks AY101, AY102, AZ1O1, AZ102; the offgas is cooled from a nominal 100 F to 40 F. Resulting condensation removes tritiated vapor from the exhaust stack stream. The piping system includes a package outdoor air-cooled water chiller with parallel redundant circulating pumps; the condenser coil is located inside a shielded ventilation equipment cell. The tests verify correct system operation and correct indications displayed by the central Monitor and Control System.

  3. Cool Roof Systems; What is the Condensation Risk?

    SciTech Connect

    Kehrer, Manfred; Pallin, Simon B

    2014-01-01

    A white roof, or cool roof, is constructed to decrease thermal loads from solar radiation, therefore saving energy by decreasing the cooling demands. Unfortunately, cool roofs with a mechanically attached membrane have shown a higher risk of intermediate condensation in the materials below the membrane in certain climates (Ennis & Kehrer, 2011) and in comparison with similar constructions with a darker exterior surface (Bludau, Zirkelbach, & Kuenzel, 2009). As a consequence, questions have been raised regarding the sustainability and reliability of using cool roof membranes in northern U.S. climate zones.

  4. BROMINE CHLORIDE--AN ALTERNATIVE TO CHLORINE FOR FOULING CONTROL IN CONDENSER COOLING SYSTEMS

    EPA Science Inventory

    The report gives results of a comparison of bromine chloride and chlorine for fouling control in condenser cooling systems, by evaluating their decay rate in estuarine cooling water and their fouling control effectiveness. The program was conducted at an 1100-MWe, fossil-fueled, ...

  5. The performance of a mobile air conditioning system with a water cooled condenser

    NASA Astrophysics Data System (ADS)

    Di Battista, Davide; Cipollone, Roberto

    2015-11-01

    Vehicle technological evolution lived, in recent years, a strong acceleration due to the increased awareness of environmental issues related to pollutants and climate altering emissions. This resulted in a series of international regulations on automotive sector which put technical challenges that must consider the engine and the vehicle as a global system, in order to improve the overall efficiency of the system. The air conditioning system of the cabin, for instance, is the one of the most important auxiliaries in a vehicle and requires significant powers. Its performances can be significantly improved if it is integrated within the engine cooling circuit, eventually modified with more temperature levels. In this paper, the Authors present a mathematical model of the A/C system, starting from its single components: compressors, condenser, flush valve and evaporator and a comparison between different refrigerant fluid. In particular, it is introduced the opportunity to have an A/C condenser cooled by a water circuit instead of the external air linked to the vehicle speed, as in the actual traditional configuration. The A/C condenser, in fact, could be housed on a low temperature water circuit, reducing the condensing temperature of the refrigeration cycle with a considerable efficiency increase.

  6. Effect of makeup water properties on the condenser fouling in power planr cooling system

    SciTech Connect

    Safari, I.; Walker, M.; Abbasian, J.; Arastoopour, H.; Hsieh, M-K.; Dzombak, D.; Miller, D.

    2011-01-01

    The thermoelectric power industry in the U.S. uses a large amount of fresh water. As available freshwater for use in thermoelectric power production becomes increasingly limited, use of nontraditional water sources is of growing interest. Utilization of nontraditional water, in cooling systems increases the potential for mineral precipitation on heat exchanger surfaces. In that regard, predicting the accelerated rate of scaling and fouling in condenser is crucial to evaluate the condenser performance. To achieve this goal, water chemistry should be incorporated in cooling system modeling and simulation. This paper addresses the effects of various makeup water properties on the cooling system, namely pH and aqueous speciation, both of which are important factors affecting the fouling rate in the main condenser. Detailed modeling of the volatile species desorption (i.e. CO{sub 2} and NH{sub 3}), the formation of scale in the recirculating system, and the relationship between water quality and the corresponding fouling rates is presented.

  7. DIRECT EVIDENCE FOR CONDENSATION IN THE EARLY SOLAR SYSTEM AND IMPLICATIONS FOR NEBULAR COOLING RATES

    SciTech Connect

    Berg, T.; Maul, J.; Schoenhense, G.; Marosits, E.; Hoppe, P.; Ott, U.; Palme, H.

    2009-09-10

    We have identified in an acid resistant residue of the carbonaceous chondrite Murchison a large number (458) of highly refractory metal nuggets (RMNs) that once were most likely hosted by Ca,Al-rich inclusions (CAIs). While osmium isotopic ratios of two randomly selected particles rule out a presolar origin, the bulk chemistry of 88 particles with sizes in the submicron range determined by energy dispersive X-ray (EDX) spectroscopy shows striking agreement with predictions of single-phase equilibrium condensation calculations. Both chemical composition and morphology strongly favor a condensation origin. Particularly important is the presence of structurally incompatible elements in particles with a single-crystal structure, which also suggests the absence of secondary alteration. The metal particles represent the most pristine early solar system material found so far and allow estimation of the cooling rate of the gaseous environment from which the first solids formed by condensation. The resulting value of 0.5 K yr{sup -1} is at least 4 orders of magnitude lower than the cooling rate of molten CAIs. It is thus possible, for the first time, to see through the complex structure of most CAIs and infer the thermal history of the gaseous reservoir from which their components formed by condensation.

  8. An assessment of the use of direct contact condensers with wet cooling systems for utility steam power plants

    SciTech Connect

    Bharathan, D; Hoo, E; D`Errico, P

    1992-02-01

    Potential use of a direct contact condenser for steam recovery at the turbine exhaust of a utility power plant using a wet cooling system is investigated. To maintain condensate separate from the cooling water, a bank of plate heat exchangers is used. In a case study for a nominal 130-MW steam power plant, two heat rejection systems, one using a conventional surface condenser and another using a direct contact condenser together with a set of plate heat exchangers are compared on the basis of their performance, operation and maintenance, and system economics. Despite a higher initial cost for the direct contact system, the advantages it offers suggests that this system is viable both technically and economically. Key to the improvements the direct contact system offers is a higher equivalent availability for the power system. Reduction of dissolved oxygen and other metallic ions in the condensate, reduced use of chemical scavengers and polishers, and potential elimination of a plant floor are also major benefits of this system. Drawbacks include added plant components and higher initial cost. The potential for long-term cost reduction for the direct contact system is also identified.

  9. Passive containment cooling system

    DOEpatents

    Billig, P.F.; Cooke, F.E.; Fitch, J.R.

    1994-01-25

    A passive containment cooling system includes a containment vessel surrounding a reactor pressure vessel and defining a drywell therein containing a non-condensable gas. An enclosed wetwell pool is disposed inside the containment vessel, and a gravity driven cooling system (GDCS) pool is disposed above the wetwell pool in the containment vessel and is vented to the drywell. An isolation pool is disposed above the GDCS pool and includes an isolation condenser therein. The condenser has an inlet line disposed in flow communication with the drywell for receiving the non-condensable gas along with any steam released therein following a loss-of-coolant accident (LOCA). The condenser also has an outlet line disposed in flow communication with the drywell for returning to the drywell both liquid condensate produced upon cooling of the steam and the non-condensable gas for reducing pressure within the containment vessel following the LOCA. 1 figure.

  10. Passive containment cooling system

    DOEpatents

    Billig, Paul F.; Cooke, Franklin E.; Fitch, James R.

    1994-01-01

    A passive containment cooling system includes a containment vessel surrounding a reactor pressure vessel and defining a drywell therein containing a non-condensable gas. An enclosed wetwell pool is disposed inside the containment vessel, and a gravity driven cooling system (GDCS) pool is disposed above the wetwell pool in the containment vessel and is vented to the drywell. An isolation pool is disposed above the GDCS pool and includes an isolation condenser therein. The condenser has an inlet line disposed in flow communication with the drywell for receiving the non-condensable gas along with any steam released therein following a loss-of-coolant accident (LOCA). The condenser also has an outlet line disposed in flow communication with the drywell for returning to the drywell both liquid condensate produced upon cooling of the steam and the non-condensable gas for reducing pressure within the containment vessel following the LOCA.

  11. Neutron star cooling and pion condensation

    NASA Technical Reports Server (NTRS)

    Umeda, Hideyuki; Nomoto, Ken'ichi; Tsuruta, Sachiko; Muto, Takumi; Tatsumi, Toshitaka

    1994-01-01

    The nonstandard cooling of a neutron star with the central pion core is explored. By adopting the latest results from the pion condensation theory, neutrino emissivity is calulated for both pure charged pions and a mixture of charged and neutral pions, and the equations of state are constructed for the pion condensate. The effect of superfluidity on cooling is investigated, adopting methods more realistic than in previous studies. Our theoretical models are compared with the currently updated observational data, and possible implications are explored.

  12. Study on cooling of positronium for Bose–Einstein condensation

    NASA Astrophysics Data System (ADS)

    Shu, K.; Fan, X.; Yamazaki, T.; Namba, T.; Asai, S.; Yoshioka, K.; Kuwata-Gonokami, M.

    2016-05-01

    A proposed new method of cooling positronium is to realize the Bose–Einstein condensation (BEC) of positronium. We perform detailed studies of three processes: (1) thermalization processes between positronium and the silica walls of a cavity, (2) Ps–Ps scattering and (3) laser cooling. The thermalization process is shown to be not sufficient for BEC. Ps–Ps collision is shown to have a big effect on the cooling performance. We combine both methods and establish an efficient cooling process for BEC. We also propose a new optical laser system for the cooling.

  13. Hydronic rooftop cooling systems

    DOEpatents

    Bourne, Richard C.; Lee, Brian Eric; Berman, Mark J.

    2008-01-29

    A roof top cooling unit has an evaporative cooling section that includes at least one evaporative module that pre-cools ventilation air and water; a condenser; a water reservoir and pump that captures and re-circulates water within the evaporative modules; a fan that exhausts air from the building and the evaporative modules and systems that refill and drain the water reservoir. The cooling unit also has a refrigerant section that includes a compressor, an expansion device, evaporator and condenser heat exchangers, and connecting refrigerant piping. Supply air components include a blower, an air filter, a cooling and/or heating coil to condition air for supply to the building, and optional dampers that, in designs that supply less than 100% outdoor air to the building, control the mixture of return and ventilation air.

  14. Implementation of Sub-Cooling of Cryogenic Propellants by Injection of Non-condensing Gas to the Generalized Fluid Systems Simulation Program (GFSSP)

    NASA Technical Reports Server (NTRS)

    Huggett, Daniel J.; Majumdar, Alok

    2013-01-01

    Cryogenic propellants are readily heated when used. This poses a problem for rocket engine efficiency and effective boot-strapping of the engine, as seen in the "hot" LOX (Liquid Oxygen) problem on the S-1 stage of the Saturn vehicle. In order to remedy this issue, cryogenic fluids were found to be sub-cooled by injection of a warm non-condensing gas. Experimental results show that the mechanism behind the sub-cooling is evaporative cooling. It has been shown that a sub-cooled temperature difference of approximately 13 deg F below saturation temperature [1]. The phenomenon of sub-cooling of cryogenic propellants by a non-condensing gas is not readily available with the General Fluid System Simulation Program (GFSSP) [2]. GFSSP is a thermal-fluid program used to analyze a wide variety of systems that are directly impacted by thermodynamics and fluid mechanics. In order to model this phenomenon, additional capabilities had to be added to GFSSP in the form of a FORTRAN coded sub-routine to calculate the temperature of the sub-cooled fluid. Once this was accomplished, the sub-routine was implemented to a GFSSP model that was created to replicate an experiment that was conducted to validate the GFSSP results.

  15. Varying duty operation of air-cooled condenser units

    NASA Astrophysics Data System (ADS)

    Milman, O. O.; Kondratev, A. V.; Ptakhin, A. V.; Dunaev, S. N.; Kirjukhin, A. V.

    2016-05-01

    Results of experimental investigations of operation modes of air-cooled condensers (ACC) under design and varying duty conditions are presented. ACCs with varying cooling airflow rates under constant heat load and with constant cooling airflow under varying heat load are examined. Diagrams of heat transfer coefficients and condensation pressures on the heat load and cooling airflow are obtained. It is found that, if the relative heat load is in the range from 0.6 to 1.0 of the nominal value, the ACC heat transfer coefficient varies insignificantly, unlike that of the water-cooled surface condensers. The results of the determination of "zero points" are given, i.e., the attainable pressure in air-cooled condensing units (ACCU), if there is no heat load for several values of working water temperature at the input of water-jet ejectors and liquid ring vacuum pump. The results of the experimental determination of atmospheric air suction into the ACC vacuum system. The effect of additional air suctions in the steam pipe on ACCU characteristics is analyzed. The thermal mapping of ACC heat exchange surfaces from the cooling air inlet is carried out. The dependence of the inefficient heat exchange zone on the additional air suction into the ACC vacuum system is given. It is shown that, if there is no additional air suction into the ACC vacuum system, the inefficient heat exchange zone is not located at the bottom of the first pass tubes, and their portion adjacent to the bottom steam pipe works efficiently. Design procedures for the ACC varying duty of capacitors are presented, and their adequacy for the ACCU varying duty estimation is analyzed.

  16. EXPERIMENTAL EVALUATION OF A NOVEL FULL-SCALE EVAPORATIVELY COOLED CONDENSER

    EPA Science Inventory

    The report compares the performance of a novel evaporatively cooled condenser with that of a conventional air-cooled condenser for a split-system heat pump. The system was tested in an environmentally controlled test chamber that is able to simulate test conditions as specified b...

  17. Optimization of a condensed-neon cooling system for a HTS synchronous motor with Gd-bulk HTS field-pole magnets

    NASA Astrophysics Data System (ADS)

    Felder, B.; Miki, M.; Tsuzuki, K.; Izumi, M.; Hayakawa, H.

    2010-06-01

    The axial-gap synchronous machine developed in our laboratory is based on Gd-bulk HTS field-pole magnets, able to trap a part of the magnetic flux they are submitted to when cooled down below Tc. At the liquid nitrogen temperature, by the Pulsed-Field Magnetization (PFM), 1.04 T was trapped in 60 mm-diameter and 20 mm-thickness magnets, leading to an output power of the motor of 10 kW at 720 rpm. To enhance this performance, we have to increase the total amount of trapped flux in the bulk, the shortest way being to decrease the temperature of the bulk HTS. Thus, we focused on the improvement of the condensed-neon cooling system, a closed-cycle thermosyphon, so that it provided enough cooling power to lead the rotor plate enclosing the magnets to a low temperature. The present study implied coming out with a new fin-oriented design of the condensation chamber; hence, the numeric calculations and FEM software (ANSYS) heat transfer simulations were conducted for various shapes and positions of the fins. The trapezoidal design offering the best efficiency was then manufactured for testing in a heat-load test configuration, leading to cooling times divided by three and a maximum heat load endured of 55 W.

  18. Experimental study of condensate subcooling with the use of a model of an air-cooled condenser

    NASA Astrophysics Data System (ADS)

    Sukhanov, V. A.; Bezukhov, A. P.; Bogov, I. A.; Dontsov, N. Y.; Volkovitsky, I. D.; Tolmachev, V. V.

    2016-01-01

    Water-supply deficit is now felt in many regions of the world. This hampers the construction of new steam-turbine and combined steam-and-gas thermal power plants. The use of dry cooling systems and, specifically, steam-turbine air-cooled condensers (ACCs) expands the choice of sites for the construction of such power plants. The significance of condensate subcooling Δ t as a parameter that negatively affects the engineering and economic performance of steam-turbine plants is thereby increased. The operation and design factors that influence the condensate subcooling in ACCs are revealed, and the research objective is, thus, formulated properly. The indicated research was conducted through physical modeling with the use of the Steam-Turbine Air-Cooled Condenser Unit specialized, multipurpose, laboratory bench. The design and the combined schematic and measurement diagram of this test bench are discussed. The experimental results are presented in the form of graphic dependences of the condensate subcooling value on cooling ratio m and relative weight content ɛ' of air in steam at the ACC inlet at different temperatures of cooling air t ca ' . The typical ranges of condensate subcooling variation (4 ≤ Δ t ≤ 6°C, 2 ≤ Δ t ≤ 4°C, and 0 ≤ Δ t ≤ 2°C) are identified based on the results of analysis of the attained Δ t levels in the ACC and numerous Δ t reduction estimates. The corresponding ranges of cooling ratio variation at different temperatures of cooling air at the ACC inlet are specified. The guidelines for choosing the adjusted ranges of cooling ratio variation with account of the results of experimental studies of the dependences of the absolute pressure of the steam-air mixture in the top header of the ACC and the heat flux density on the cooling ratio at different temperatures of cooling air at the ACC inlet are given.

  19. Cooling-Trough Condenser for Sublimation Tubes

    NASA Astrophysics Data System (ADS)

    Eisenbraun, E. J.; Lucas, J. M.

    1995-11-01

    A wrap-around, trough condenser for use with large diameter (2.5") sublimation tubes is described. The design permits attachment of the condenser to the sublimation tube without removing the tube from the heater. It also permits the use of a variety of liquid (tap water, Dry Ice, and alcohol or acetone) or solid (ice or Dry Ice) coolants.

  20. Energy Conservation in Air Cooled Condenser: A Case Study

    NASA Astrophysics Data System (ADS)

    Mallick, D. S.; Paul, S.

    2014-01-01

    Air cooled condensers were first introduced in the US power industry in the early 1970s, but only during the last few decades has the number of installations greatly increased, largely to mitigate the problem of available water supply. Air may be used as a cooling medium in condensers where, primarily, there is scarcity of water, or where the ambient remains significantly cold for major parts of the year. Air cooled condensers are designed considering the design ambient conditions of summer. During winter months, if the air flow rate over the heat transfer surfaces is kept constant, it leads to improved condenser vacuum, and consequently, improved heat rate. Alternatively, the fans may be run at lower speeds, by using variable frequency drives (VFD), so as to keep the condenser vacuum constant, resulting uniform heat rate. This paper compares the economics between the power saved by the use of VFD in the condenser fans, keeping constant heat rate throughout the year, vis-à-vis, the saving in fuel, effected when the fans are operated at constant speed throughout the year and thus achieving improved heat rate during colder ambient.

  1. Emergency cooling system and method

    DOEpatents

    Oosterkamp, W.J.; Cheung, Y.K.

    1994-01-04

    An improved emergency cooling system and method are disclosed that may be adapted for incorporation into or use with a nuclear BWR wherein a reactor pressure vessel (RPV) containing a nuclear core and a heat transfer fluid for circulation in a heat transfer relationship with the core is housed within an annular sealed drywell and is fluid communicable therewith for passage thereto in an emergency situation the heat transfer fluid in a gaseous phase and any noncondensibles present in the RPV, an annular sealed wetwell houses the drywell, and a pressure suppression pool of liquid is disposed in the wetwell and is connected to the drywell by submerged vents. The improved emergency cooling system and method has a containment condenser for receiving condensible heat transfer fluid in a gaseous phase and noncondensibles for condensing at least a portion of the heat transfer fluid. The containment condenser has an inlet in fluid communication with the drywell for receiving heat transfer fluid and noncondensibles, a first outlet in fluid communication with the RPV for the return to the RPV of the condensed portion of the heat transfer fluid and a second outlet in fluid communication with the drywell for passage of the noncondensed balance of the heat transfer fluid and the noncondensibles. The noncondensed balance of the heat transfer fluid and the noncondensibles passed to the drywell from the containment condenser are mixed with the heat transfer fluid and the noncondensibles from the RPV for passage into the containment condenser. A water pool is provided in heat transfer relationship with the containment condenser and is thermally communicable in an emergency situation with an environment outside of the drywell and the wetwell for conducting heat transferred from the containment condenser away from the wetwell and the drywell. 5 figs.

  2. The cooling and condensation of flare coronal plasma

    NASA Technical Reports Server (NTRS)

    Antiochos, S. K.; Sturrock, P. A.

    1981-01-01

    A model is investigated for the decay of flare heated coronal loops in which rapid radiative cooling at the loop base creates strong pressure gradients which, in turn, generate large (supersonic) downward flows. The coronal material cools and 'condenses' onto the flare chromosphere. The features which distinguish this model from previous models of flare cooling are: (1) most of the thermal energy of the coronal plasma may be lost by mass motion rather than by conduction or coronal radiation; (2) flare loops are not isobaric during their decay phase, and large downward velocities are present near the footpoints; (3) the differential emission measure q has a strong temperature dependence.

  3. Fouling of Air Cooled Condensers On the Air Side

    NASA Astrophysics Data System (ADS)

    Marie, Hazel; Matune, Nicholas

    2013-11-01

    As the electrical power demand increases and water resources become more limited, fouling on the air side of Air Cooled Condensers (ACC) is a growing concern. The objective of this study was to experimentally and computationally calculate the convection heat transfer coefficient for both a clean and fouled condenser. Bee pollen was selected as the experimental fouling particle, and engineering data for similar particles were used for the computational model. Both the experimental and computational results showing the negative impact fouling has a on the heat transfer will be presented.

  4. Air-cooled condensers eliminate plant water use

    SciTech Connect

    Wurtz, W.; Peltier, R.

    2008-09-15

    River or ocean water has been the mainstay for condensing turbine exhaust steam since the first steam turbine began generating electricity. A primary challenge facing today's plant developers, especially in drought-prone regions, is incorporating processes that reduce plant water use and consumption. One solution is to shed the conventional mindset that once-through cooling is the only option and adopt dry cooling technologies that reduce plant water use from a flood to a few sips. A case study at the Astoria Energy plant, New York City is described. 14 figs.

  5. Cooling of a Bose-Einstein Condensate by Spin Distillation.

    PubMed

    Naylor, B; Maréchal, E; Huckans, J; Gorceix, O; Pedri, P; Vernac, L; Laburthe-Tolra, B

    2015-12-11

    We propose and experimentally demonstrate a new cooling mechanism leading to purification of a Bose-Einstein condensate (BEC). Our scheme starts with a BEC polarized in the lowest energy spin state. Spin excited states are thermally populated by lowering the single particle energy gap set by the magnetic field. Then, these spin-excited thermal components are filtered out, which leads to an increase of the BEC fraction. We experimentally demonstrate such cooling for a spin 3 ^{52}Cr dipolar BEC. Our scheme should be applicable to Na or Rb, with the perspective to reach temperatures below 1 nK. PMID:26705630

  6. Heat conduction boundary layers of condensed clumps in cooling flows

    NASA Astrophysics Data System (ADS)

    Boehringer, H.; Fabian, A. C.

    1989-04-01

    The structure of heat conduction boundary layers of gaseous condensations embedded in the hot intergalactic gas in clusters of galaxies is investigated by means of steady, one-dimensional, hydrodynamic models. It is assumed that heat conduction is effective only on scales much smaller than the total region of the cooling flow. Models are calculated for an arbitrary scaling factor, accounting for the reduction in heat conduction efficiency compared to the classical Spitzer case. The results imply a lower limit to the size spectrum of the condensations. The enhancement of cooling in the ambient medium due to heat conduction losses is calculated for a range of clump parameters. The luminosity of several observable emission lines, the extreme ultraviolet (EUV) and soft X-ray emission spectrum, and the column density of some important ions are determined for the model boundary layers and compared with observations.

  7. Self-Transport of Condensed Liquid in Micro Cooling Device Using Distributed Meniscus Pumping.

    PubMed

    So, Hongyun; Pisano, Albert P

    2015-06-16

    This paper reports a reliable passive micro pump system combining the physical properties of a tapered microchannel and sharp microstructures. This tailored microchannel with triple-spike microstructures was created to transport condensed liquid into the reservoir chamber in a micro cooling device and in the case of chip off-mode prepare the next cooling cycle before chip on-mode, allowing the reliable and continuous circulation of coolant without liquid being trapped in the vapor channel causing dryout limitation. At the tapered channel end, the pinned liquid meniscus was distributed by a middle spike and then continued to overflow into the condenser chamber due to extended capillary action. PMID:26010771

  8. Evaporative cooling enhanced cold storage system

    DOEpatents

    Carr, Peter

    1991-01-01

    The invention provides an evaporatively enhanced cold storage system wherein a warm air stream is cooled and the cooled air stream is thereafter passed into contact with a cold storage unit. Moisture is added to the cooled air stream prior to or during contact of the cooled air stream with the cold storage unit to effect enhanced cooling of the cold storage unit due to evaporation of all or a portion of the added moisture. Preferably at least a portion of the added moisture comprises water condensed during the cooling of the warm air stream.

  9. Evaporative cooling enhanced cold storage system

    DOEpatents

    Carr, P.

    1991-10-15

    The invention provides an evaporatively enhanced cold storage system wherein a warm air stream is cooled and the cooled air stream is thereafter passed into contact with a cold storage unit. Moisture is added to the cooled air stream prior to or during contact of the cooled air stream with the cold storage unit to effect enhanced cooling of the cold storage unit due to evaporation of all or a portion of the added moisture. Preferably at least a portion of the added moisture comprises water condensed during the cooling of the warm air stream. 3 figures.

  10. Pigmented foils for radiative cooling and condensation irrigation

    SciTech Connect

    Nilsson, T.M.J.; Vargas, W.E.; Niklasson, G.A.

    1994-12-31

    This paper reports on the development of pigmented polyethylene foils for radiative cooling. The optical properties of the foils were optimized for applications in day-time radiative cooling and water condensation. The authors first study highly scattering foils used as convection shields. These cover foils combine a high solar reflectance and a high transmittance in the atmospheric window region in the infrared. Different pigment materials were studied and ZnS was the only one that could prevent heating of an underlying blackbody at noon, with the sun in its zenith. A 400 {micro}m thick ZnS pigmented polyethylene foil with a pigment volume fraction of 0.15 was tested in Tanzania. At noon the observed temperature of the covered blackbody was only 1.5 K above the ambient. Secondly, they study the potential for condensation of water in an arid region. Pigmented foils for this purpose should combine a high solar reflectance and a high infrared emittance, in order to promote condensation by the radiative cooling effect. Titanium dioxide is a fairly good infrared emitter, but the emittance can be improved by using a mixture of TiO{sub 2} and BaSO{sub 4} pigments or only employing a composite SiO{sub 2}/TiO{sub 2}. Field tests with a 390 {micro}m thick polyethylene foil with TiO{sub 2} and BaSO{sub 4} pigments gave encouraging results.

  11. Data center cooling system

    DOEpatents

    Chainer, Timothy J; Dang, Hien P; Parida, Pritish R; Schultz, Mark D; Sharma, Arun

    2015-03-17

    A data center cooling system may include heat transfer equipment to cool a liquid coolant without vapor compression refrigeration, and the liquid coolant is used on a liquid cooled information technology equipment rack housed in the data center. The system may also include a controller-apparatus to regulate the liquid coolant flow to the liquid cooled information technology equipment rack through a range of liquid coolant flow values based upon information technology equipment temperature thresholds.

  12. Reactor core isolation cooling system

    DOEpatents

    Cooke, F.E.

    1992-12-08

    A reactor core isolation cooling system includes a reactor pressure vessel containing a reactor core, a drywell vessel, a containment vessel, and an isolation pool containing an isolation condenser. A turbine is operatively joined to the pressure vessel outlet steamline and powers a pump operatively joined to the pressure vessel feedwater line. In operation, steam from the pressure vessel powers the turbine which in turn powers the pump to pump makeup water from a pool to the feedwater line into the pressure vessel for maintaining water level over the reactor core. Steam discharged from the turbine is channeled to the isolation condenser and is condensed therein. The resulting heat is discharged into the isolation pool and vented to the atmosphere outside the containment vessel for removing heat therefrom. 1 figure.

  13. Reactor core isolation cooling system

    DOEpatents

    Cooke, Franklin E.

    1992-01-01

    A reactor core isolation cooling system includes a reactor pressure vessel containing a reactor core, a drywell vessel, a containment vessel, and an isolation pool containing an isolation condenser. A turbine is operatively joined to the pressure vessel outlet steamline and powers a pump operatively joined to the pressure vessel feedwater line. In operation, steam from the pressure vessel powers the turbine which in turn powers the pump to pump makeup water from a pool to the feedwater line into the pressure vessel for maintaining water level over the reactor core. Steam discharged from the turbine is channeled to the isolation condenser and is condensed therein. The resulting heat is discharged into the isolation pool and vented to the atmosphere outside the containment vessel for removing heat therefrom.

  14. Cooling water distribution system

    DOEpatents

    Orr, Richard

    1994-01-01

    A passive containment cooling system for a nuclear reactor containment vessel. Disclosed is a cooling water distribution system for introducing cooling water by gravity uniformly over the outer surface of a steel containment vessel using an interconnected series of radial guide elements, a plurality of circumferential collector elements and collector boxes to collect and feed the cooling water into distribution channels extending along the curved surface of the steel containment vessel. The cooling water is uniformly distributed over the curved surface by a plurality of weirs in the distribution channels.

  15. Excitonic condensation in bilayer systems

    NASA Astrophysics Data System (ADS)

    Su, Jung-Jung

    Among the many examples of Bose condensation considered in physics, electron-hole-pair (exciton) condensation has maintained special interest because it has been difficult to realize experimentally, and because of controversy about condensate properties. In this thesis, we studied the various aspects of spontaneous symmetry broken state of exciton in bilayer using mean field theory. We calculated the photoluminescence of excitonic condensation created by laser. We developed a one-dimensional toy model of excitonic supercurrent using mean field theory plus non-equilibrium Green's function (NEGF) which give qualitatively consistent results with experiments. We proposed graphene bilayer as a novel system for excitonic condensation to occur and estimate it to exist even at temperature as high as room temperature.

  16. Condensation and Evaporation of Solar System Materials

    NASA Astrophysics Data System (ADS)

    Davis, A. M.; Richter, F. M.

    2003-12-01

    It is widely believed that the materials making up the solar system were derived from a nebular gas and dust cloud that went through an early high-temperature stage during which virtually all of the material was in the gas phase. At one time, it was thought that the entire inner solar nebula was hot, but it is now believed that most material was processed through regions where high temperatures were achieved. Certainly some material, such as presolar grains (cf., Mendybaev et al., 2002a), has never been exposed to high temperatures. As the system cooled, solids and perhaps liquids began to condense, but at some point the partially condensed materials became isolated from the remaining gas. Various lines of evidence support this view. At the largest scale, there is the observation that the Earth, Moon, Mars, and all chondritic meteorites except for the CI chondrites are depleted to varying degrees in the abundances of moderately volatile elements relative to bulk solar system composition. The CI chondrites reflect the bulk composition of the solar system for all but hydrogen, carbon, nitrogen, oxygen, and the rare gases, the most volatile elements (see Chapter 1.03; Palme et al., 1988; McDonough and Sun, 1995; Humayun and Cassen, 2000). The depletions in moderately volatile elements are, to a significant degree, correlated with condensation temperature, suggesting progressive removal of gas as condensation proceeded ( Cassen, 1996). Additional observations that can be explained by partial condensation are that various particularly primitive components of meteorites (e.g., calcium-, aluminum-rich refractory inclusions, and certain metal grains) have mineralogy and/or details of their chemical composition that are remarkably similar to what is calculated for equilibrium condensates from a solar composition gas. For example, the calcium-, aluminum-rich inclusions (CAIs) in chondritic meteorites have compositions very similar to that calculated for the first 5% of total

  17. Solar-powered cooling system

    SciTech Connect

    Farmer, Joseph C.

    2015-07-28

    A solar-powered adsorption-desorption refrigeration and air conditioning system that uses nanostructural materials such as aerogels, zeolites, and sol gels as the adsorptive media. Refrigerant molecules are adsorbed on the high surface area of the nanostructural material while the material is at a relatively low temperature, perhaps at night. During daylight hours, when the nanostructural materials is heated by the sun, the refrigerant are thermally desorbed from the surface of the aerogel, thereby creating a pressurized gas phase in the vessel that contains the aerogel. This solar-driven pressurization forces the heated gaseous refrigerant through a condenser, followed by an expansion valve. In the condenser, heat is removed from the refrigerant, first by circulating air or water. Eventually, the cooled gaseous refrigerant expands isenthalpically through a throttle valve into an evaporator, in a fashion similar to that in more conventional vapor recompression systems.

  18. Experimental study on the evaporative cooling of an air-cooled condenser with humidifying air

    NASA Astrophysics Data System (ADS)

    Wen, Mao-Yu; Ho, Ching-Yen; Jang, Kuang-Jang; Yeh, Cheng-Hsiung

    2014-02-01

    Using six different materials to construct a water curtain, this study aims to determine the most effective spray cooling of an air cooled heat exchanger under wet conditions. The experiments were carried out at a mass flow rate of 0.005-0.01 kg/s (spraying water), an airspeed of 0.6-2.4 m/s and a run time of 0-72 h for the material degradation tests. The experimental results indicate that the cooling efficiency, the heat rejection, and the sprinkling density increase as the amount of spraying water increases, but, the air-flow of the condenser is reduced at the same time. In addition, the cooling efficiency of the pads decreases with an increase of the inlet air velocity. In terms of experimental range, the natural wood pulp fiberscan can reach 42.7-66 % for cooling efficiency and 17.17-24.48 % for increases of heat rejection. This means that the natural wood pulp fiberscan pad most effectively enhances cooling performance, followed in terms of cooling effectiveness by the special non-woven rayon pad, the woollen blanket, biochemistry cotton and kapok, non-woven cloth of rayon cotton and kapok, and white cotton pad, respectively. However, the natural wood pulp fiberscan and special non-woven rayon display a relatively greater degradation of the cooling efficiency than the other test pads used in the material degradation tests.

  19. Passive containment cooling system

    DOEpatents

    Conway, Lawrence E.; Stewart, William A.

    1991-01-01

    A containment cooling system utilizes a naturally induced air flow and a gravity flow of water over the containment shell which encloses a reactor core to cool reactor core decay heat in two stages. When core decay heat is greatest, the water and air flow combine to provide adequate evaporative cooling as heat from within the containment is transferred to the water flowing over the same. The water is heated by heat transfer and then evaporated and removed by the air flow. After an initial period of about three to four days when core decay heat is greatest, air flow alone is sufficient to cool the containment.

  20. Cooling and condensing of sulfur and water from claus process gas

    SciTech Connect

    Palm, J. W.; Kunkel, L. V.

    1985-07-02

    The Claus process gas is cooled in a condenser to condense most of the sulfur vapor in solid form. The gas leaving the condenser is then further cooled to condense water without producing substantially any sulfur in an undesirable form. The resulting gas of reduced water content is useful in Claus reaction, particularly the low temperature Claus reaction in which the product sulfur is adsorbed on the catalyst.

  1. Organometallic Polymer Coatings for Geothermal-Fluid-Sprayed Air-Cooled Condensers: Preprint

    SciTech Connect

    Gawlik, K.; Sugama, T.; Jung, D.

    2002-08-01

    Researchers are developing polymer-based coating systems to reduce scaling and corrosion of air-cooled condensers that use a geothermal fluid spray for heat transfer augmentation. These coating systems act as barriers to corrosion to protect aluminum fins and steel tubing; they are formulated to resist the strong attachment of scale. Field tests have been done to determine the corrosion and scaling issues related to brine spraying and a promising organometallic polymer has been evaluated in salt spray tests.

  2. Cold Vacuum Drying facility condensate collection system design description (SYS 19)

    SciTech Connect

    PITKOFF, C.C.

    1999-07-06

    This document describes the Cold Vacuum Drying Facility (CVDF) condensate collection system (CCS). The function of the CCS is to collect cooling coil condensate from air-handling units in the CVDF and to isolate the condensate in collection tanks until the condensate is determined to be acceptable to drain to the effluent drain collection basin.

  3. Personal Cooling System

    NASA Technical Reports Server (NTRS)

    1986-01-01

    Cool Head, a personal cooling system for use in heat stress occupations, is a spinoff of a channeled cooling garment for space wear. It is portable and includes a heat exchanger, control display unit, liquid reservoir and temperature control unit. The user can eliminate 40 to 60 percent of his body's heat storage and lower heart rate by 50 to 80 beats a minute. The system is used by the Army, Navy, crop dusting pilots, heavy equipment operators and auto racing drivers and is marketed by Life Enhancement Technologies, LLC. Further applications are under consideration.

  4. Superconductor rotor cooling system

    DOEpatents

    Gamble, Bruce B.; Sidi-Yekhlef, Ahmed; Schwall, Robert E.; Driscoll, David I.; Shoykhet, Boris A.

    2002-01-01

    A system for cooling a superconductor device includes a cryocooler located in a stationary reference frame and a closed circulation system external to the cryocooler. The closed circulation system interfaces the stationary reference frame with a rotating reference frame in which the superconductor device is located. A method of cooling a superconductor device includes locating a cryocooler in a stationary reference frame, and transferring heat from a superconductor device located in a rotating reference frame to the cryocooler through a closed circulation system external to the cryocooler. The closed circulation system interfaces the stationary reference frame with the rotating reference frame.

  5. Superconductor rotor cooling system

    DOEpatents

    Gamble, Bruce B.; Sidi-Yekhlef, Ahmed; Schwall, Robert E.; Driscoll, David I.; Shoykhet, Boris A.

    2004-11-02

    A system for cooling a superconductor device includes a cryocooler located in a stationary reference frame and a closed circulation system external to the cryocooler. The closed circulation system interfaces the stationary reference frame with a rotating reference frame in which the superconductor device is located. A method of cooling a superconductor device includes locating a cryocooler in a stationary reference frame, and transferring heat from a superconductor device located in a rotating reference frame to the cryocooler through a closed circulation system external to the cryocooler. The closed circulation system interfaces the stationary reference frame with the rotating reference frame.

  6. Monitoring Cray Cooling Systems

    SciTech Connect

    Maxwell, Don E; Ezell, Matthew A; Becklehimer, Jeff; Donovan, Matthew J; Layton, Christopher C

    2014-01-01

    While sites generally have systems in place to monitor the health of Cray computers themselves, often the cooling systems are ignored until a computer failure requires investigation into the source of the failure. The Liebert XDP units used to cool the Cray XE/XK models as well as the Cray proprietary cooling system used for the Cray XC30 models provide data useful for health monitoring. Unfortunately, this valuable information is often available only to custom solutions not accessible by a center-wide monitoring system or is simply ignored entirely. In this paper, methods and tools used to harvest the monitoring data available are discussed, and the implementation needed to integrate the data into a center-wide monitoring system at the Oak Ridge National Laboratory is provided.

  7. State waste discharge permit application for cooling water and condensate discharges

    SciTech Connect

    Haggard, R.D.

    1996-08-12

    The following presents the Categorical State Waste Discharge Permit (SWDP) Application for the Cooling Water and Condensate Discharges on the Hanford Site. This application is intended to cover existing cooling water and condensate discharges as well as similar future discharges meeting the criteria set forth in this document.

  8. Waveguide cooling system

    NASA Technical Reports Server (NTRS)

    Chen, B. C. J.; Hartop, R. W. (Inventor)

    1981-01-01

    An improved system is described for cooling high power waveguides by the use of cooling ducts extending along the waveguide, which minimizes hot spots at the flanges where waveguide sections are connected together. The cooling duct extends along substantially the full length of the waveguide section, and each flange at the end of the section has a through hole with an inner end connected to the duct and an opposite end that can be aligned with a flange hole in another waveguide section. Earth flange is formed with a drainage groove in its face, between the through hole and the waveguide conduit to prevent leakage of cooling fluid into the waveguide. The ducts have narrowed sections immediately adjacent to the flanges to provide room for the installation of fasteners closely around the waveguide channel.

  9. Evolutionary games of condensates in driven and dissipative bosonic systems

    NASA Astrophysics Data System (ADS)

    Knebel, Johannes; Weber, Markus F.; Krüger, Torben; Frey, Erwin

    2015-03-01

    Condensation is a collective behavior of particles observed in both classical and quantum physics. For example, when an equilibrated, dilute gas of bosonic particles is cooled to a temperature near absolute zero, the ground state becomes macroscopically occupied (Bose-Einstein condensation). Whether novel condensation phenomena occur far from equilibrium is a topic of vivid research. Only recently has it been proposed that a driven and dissipative gas of bosons can condense not only into a single, but also into multiple non-degenerate states. This phenomenon may occur when a system of non-interacting bosons is weakly coupled to a reservoir and is driven by an external time-periodic force (Floquet system). Coherence becomes negligible and the condensation is described by a Pauli master equation, which also arises in the evolutionary dynamics of classical agents. In our work, we apply concepts from evolutionary dynamics to determine the states that become condensates. This condensate selection is guided by the vanishing of relative entropy production. We find that the system of condensates never comes to rest: The occupation numbers of condensates oscillate, which we demonstrate for a rock-paper-scissors game of condensates. Deutsche Forschungsgemeinschaft (SFB-TR12), German Excellence Initiative (Nanosystems Initiative Munich), Center for NanoScience Munich, Studienstiftung des Deutschen Volkes.

  10. Improving the energy efficiency of refrigeration plants by decreasing the temperature difference in air-cooled condensers

    NASA Astrophysics Data System (ADS)

    Shishov, V. V.; Talyzin, M. S.

    2015-09-01

    The electric energy consumption efficiency is estimated in comparing the real refrigeration machine cycle with the theoretical inverse Carnot cycle. The potential for saving electricity in using aircooled condensers with different values of temperature difference is shown. A procedure for calculating a refrigerating system with the evaporation temperature equal to -10°C, which corresponds at this temperature level to the thermal load of a standard supermarket, is described. The calculation was carried out taking into account the annual profile of temperatures in the indicated locality and based on the possibility of adjusting the condenser capacity for maintaining constant condensation temperature. The payback period in case of using condensers with different values of temperature difference is calculated; for example, in using condensers with a temperature difference of less than 15 K, the payback period will be less than one year. Decreasing the temperature difference results, on one hand, in a larger annual consumption of electric energy by the condenser fans, and on the other hand, it results in a lower condensation pressure, which leads to a smaller annual consumption of energy by the compressor unit. As a result, the total amount of energy consumed by the refrigeration system decreases so that despite a higher cost of condensers designed to operate at lower values of temperature difference, it becomes possible to achieve the above-mentioned payback period. Additionally, the payback period in case of using an air-cooled microchannel aluminum condenser was calculated: in case of using such a condenser with a temperature difference of 8 K instead of the condenser with the temperature difference equal to 15 K, the payback period will be less than half a year. Recommendations for designing new refrigeration systems equipped with air-cooled condensers are given.

  11. Passive cooling system for a vehicle

    DOEpatents

    Hendricks, Terry Joseph; Thoensen, Thomas

    2005-11-15

    A passive cooling system for a vehicle (114) transfers heat from an overheated internal component, for example, an instrument panel (100), to an external portion (116) of the vehicle (114), for example, a side body panel (126). The passive cooling system includes one or more heat pipes (112) having an evaporator section (118) embedded in the overheated internal component and a condenser section (120) at the external portion (116) of the vehicle (114). The evaporator (118) and condenser (120) sections are in fluid communication. The passive cooling system may also include a thermally conductive film (140) for thermally connecting the evaporator sections (118) of the heat pipes (112) to each other and to the instrument panel (100).

  12. Passive Cooling System for a Vehicle

    DOEpatents

    Hendricks, T. J.; Thoensen, T.

    2005-11-15

    A passive cooling system for a vehicle (114) transfers heat from an overheated internal component, for example, an instrument panel (100), to an external portion (116) of the vehicle (114), for example, a side body panel (126). The passive cooling system includes one or more heat pipes (112) having an evaporator section (118) embedded in the overheated internal component and a condenser section (120) at the external portion (116) of the vehicle (114). The evaporator (118) and condenser (120) sections are in fluid communication. The passive cooling system may also include a thermally conductive film (140) for thermally connecting the evaporator sections (118) of the heat pipes (112) to each other and to the instrument panel (100).

  13. A cooling water system copper corrosion study

    SciTech Connect

    Pulkrabek, J.W.

    1998-07-01

    The plant has four units that have been operating normally for 12--33 years. Two of the units are 70 MW sister units that have copper alloy once-through condensers. The other two units are 350 MW and 500 MW units with copper alloy condensers and cooling towers. No cooling water related tube leaks had been experienced. Until 1993, the only chemicals used were sulfuric acid for pH control of the cooling tower systems and chlorine for biological control. The units were chlorinated for one hour per day per condenser. In early July 1992, their copper grab sample at the plant discharge to the river exceeded the weekly environmental limit. In fact, it was so high that there was a slim chance of coming in under their monthly average copper limit unless something was done quickly. The result of this incident was an extensive study of their plant wastewater and cooling systems. The study revealed that the elevated copper problem had existed sporadically for several years. Initially, copper control was achieved by altering the wastewater treatment processes and cooling tower blowdown flow path. Two extended trials, one with tolyltriazole (TTA) and one with a chemically modified benzotriazole (BZT) were performed. Optimal control of copper corrosion was eventually achieved by the application of a TTA treatment program in which the feed rates are adjusted based on on-line corrosion monitoring measurements. This report documents experiences and results over the past six years.

  14. Cooling Floor AC Systems

    NASA Astrophysics Data System (ADS)

    Jun, Lu; Hao, Ding; Hong, Zhang; Ce, Gao Dian

    The present HVAC equipments for the residential buildings in the Hot-summer-and-Cold-winter climate region are still at a high energy consuming level. So that the high efficiency HVAC system is an urgently need for achieving the preset government energy saving goal. With its advantage of highly sanitary, highly comfortable and uniform of temperature field, the hot-water resource floor radiation heating system has been widely accepted. This paper has put forward a new way in air-conditioning, which combines the fresh-air supply unit and such floor radiation system for the dehumidification and cooling in summer or heating in winter. By analyze its advantages and limitations, we found that this so called Cooling/ Heating Floor AC System can improve the IAQ of residential building while keep high efficiency quality. We also recommend a methodology for the HVAC system designing, which will ensure the reduction of energy cost of users.

  15. Heat-transfer characteristics of a dry and wet/dry advanced condenser for cooling towers

    NASA Astrophysics Data System (ADS)

    Fricke, H. D.; McIlroy, K.; Webster, D. J.

    1982-06-01

    An experimental evaluation of two types of advanced, air cooled ammonia condensers for a phase change dry/wet cooling system for electric power plants is described. Condensers of similar design, but much bigger, are being tested in a 15 MWe demonstration plant. These condensers, featuring different air side augmentation, were tested in an ammonia phase change pilot plant (0.3 MWe). The first unit consisted of the integral shaved fin extruded aluminum tubing designed for dry operation. Heat transfer and air side pressure loss characteristics were measured under varying air face velocities (600 to 1000 FPM) and initial temperature differences, ITD (20 to 60 F). Overall heat transfer coefficients (based on air side surface), U, ranged between 7.0 to 8.6 Btu/hr sq ft. F. The second configuration constituted the Hoterv aluminum plate fin/tube assembly of which two different sizes (5 sq ft and 58 sq ft frontal area) were performance tested; in both dry and wet modes at 200 to 800 FPM air face velocities, ITD's of 10 to 60 F and at water deluge rates up to 3.0 gpm/ft. of core width.

  16. Deep mine cooling system

    SciTech Connect

    Conan, J.

    1984-11-06

    A deep mine cooling system comprising a compressor supplied with air and rotatively driven by a motor and an expansion turbine supplied with compressed air from said compressor and driving an actuating unit, wherein the compressed air, after leaving the compressor but prior to reaching the expansion turbine, passes through a steam generator whose output provides the energy required to operate an absorption refrigeration machine used to cool utility water for mining, said compressed air on leaving the steam generator going to a first heat exchanger in which it yields calories to a water circuit comprising a second heat exchanger, said second heat exchanger giving off the calories absorbed by the water in the first heat exchanger to the air fed by the second heat exchanger to a drying cell that is regenerated by said air from the second heat exchanger, said drying cell being part of a set of two cells working in alternation, the other cell in the set receiving the compressed air from the first heat exchanger, such that the compressed air is fed to said expansion turbine after leaving said drying unit, and wherein the air exhausted from said expansion turbine is sent to a third heat exchanger after which it is distributed according to the needs of the mine, said third exchanger being traversed by the water collected in the mine, cooled in said exchanger and circulated upon leaving said exchanger to meet the cool water requirements of the mine.

  17. Capillary Condensation of Liquid 4He in Aerogel on Cooling Through {lambda} Point

    SciTech Connect

    Miyashita, W.; Yoneyama, K.; Kato, H.; Nomura, R.; Okuda, Y.

    2006-09-07

    Capillary condensation of liquid 4He in silica aerogel with a 90% porosity was investigated visually. The initial condition of the experiment was such that liquid 4He was present in the sample cell but not in the aerogel. This situation was realized by introducing the liquid into the cell at a fast rate to avoid liquefaction in the aerogel. The free surface of the liquid rose up in the cell with filling and eventually reached the bottom of the aerogel. Then, the aerogel absorbed the liquid by capillary condensation. The height of the liquid in the aerogel rose with time t roughly as t1/2 in the normal fluid phase. This behavior was consistent with the Washburn model. When the system was cooled through the {lambda} point during the condensation, the liquid height started to rise faster in the superfluid phase with a constant velocity of about 0.3 mm/sec. The dynamics of capillary condensation was strongly dependent on whether the liquid 4He was in the normal or the superfluid phase.

  18. Startup of air-cooled condensers and dry cooling towers at low temperatures of the cooling air

    NASA Astrophysics Data System (ADS)

    Milman, O. O.; Ptakhin, A. V.; Kondratev, A. V.; Shifrin, B. A.; Yankov, G. G.

    2016-05-01

    The problems of startup and performance of air-cooled condensers (ACC) and dry cooling towers (DCT) at low cooling air temperatures are considered. Effects of the startup of the ACC at sub-zero temperatures are described. Different options of the ACC heating up are analyzed, and examples of existing technologies are presented (electric heating, heating up with hot air or steam, and internal and external heating). The use of additional heat exchanging sections, steam tracers, in the DCT design is described. The need for high power in cases of electric heating and heating up with hot air is noted. An experimental stand for research and testing of the ACC startup at low temperatures is described. The design of the three-pass ACC unit is given, and its advantages over classical single-pass design at low temperatures are listed. The formation of ice plugs inside the heat exchanging tubes during the start-up of ACC and DCT at low cooling air temperatures is analyzed. Experimental data on the effect of the steam flow rate, steam nozzle distance from the heat-exchange surface, and their orientation in space on the metal temperature were collected, and test results are analyzed. It is noted that the surface temperature at the end of the heat up is almost independent from its initial temperature. Recommendations for the safe start-up of ACCs and DCTs are given. The heating flow necessary to sufficiently heat up heat-exchange surfaces of ACCs and DCTs for the safe startup is estimated. The technology and the process of the heat up of the ACC with the heating steam external supply are described by the example of the startup of the full-scale section of the ACC at sub-zero temperatures of the cooling air, and the advantages of the proposed start-up technology are confirmed.

  19. Optimized evaporative cooling for sodium Bose-Einstein condensation against three-body loss

    SciTech Connect

    Shobu, Takahiko; Yamaoka, Hironobu; Imai, Hiromitsu; Morinaga, Atsuo; Yamashita, Makoto

    2011-09-15

    We report on a highly efficient evaporative cooling optimized experimentally. We successfully created sodium Bose-Einstein condensates with 6.4x10{sup 7} atoms starting from 6.6x10{sup 9} thermal atoms trapped in a magnetic trap by employing a fast linear sweep of radio frequency at the final stage of evaporative cooling so as to overcome the serious three-body losses. The experimental results such as the cooling trajectory and the condensate growth quantitatively agree with the numerical simulations of evaporative cooling on the basis of the kinetic theory of a Bose gas carefully taking into account our specific experimental conditions. We further discuss theoretically a possibility of producing large condensates, more than 10{sup 8} sodium atoms, by simply increasing the number of initial thermal trapped atoms and the corresponding optimization of evaporative cooling.

  20. Hybrid radiator cooling system

    DOEpatents

    France, David M.; Smith, David S.; Yu, Wenhua; Routbort, Jules L.

    2016-03-15

    A method and hybrid radiator-cooling apparatus for implementing enhanced radiator-cooling are provided. The hybrid radiator-cooling apparatus includes an air-side finned surface for air cooling; an elongated vertically extending surface extending outwardly from the air-side finned surface on a downstream air-side of the hybrid radiator; and a water supply for selectively providing evaporative cooling with water flow by gravity on the elongated vertically extending surface.

  1. Stabilization of the number of Bose-Einstein-condensed atoms in evaporative cooling via three-body recombination loss

    SciTech Connect

    Yamashita, Makoto; Mukai, Tetsuya

    2003-12-01

    The dynamics of evaporative cooling of magnetically trapped {sup 87}Rb atoms is studied on the basis of the quantum kinetic theory of a Bose gas. We carried out the quantitative calculations of the time evolution of conventional evaporative cooling where the frequency of the radio-frequency magnetic field is swept exponentially. This ''exponential-sweep cooling'' is known to become inefficient at the final stage of the cooling process due to a serious three-body recombination loss. We precisely examine how the growth of a Bose-Einstein condensate depends on the experimental parameters of evaporative cooling, such as the initial number of trapped atoms, the initial temperature, and the bias field of a magnetic trap. It is shown that three-body recombination drastically depletes the trapped {sup 87}Rb atoms as the system approaches the quantum degenerate region and the number of condensed atoms finally becomes insensitive to these experimental parameters. This result indicates that the final number of condensed atoms is well stabilized by a large nonlinear three-body loss against the fluctuations of experimental conditions in evaporative cooling.

  2. Rotary engine cooling system

    NASA Technical Reports Server (NTRS)

    Jones, Charles (Inventor); Gigon, Richard M. (Inventor); Blum, Edward J. (Inventor)

    1985-01-01

    A rotary engine has a substantially trochoidal-shaped housing cavity in which a rotor planetates. A cooling system for the engine directs coolant along a single series path consisting of series connected groups of passages. Coolant enters near the intake port, passes downwardly and axially through the cooler regions of the engine, then passes upwardly and axially through the hotter regions. By first flowing through the coolest regions, coolant pressure is reduced, thus reducing the saturation temperature of the coolant and thereby enhancing the nucleate boiling heat transfer mechanism which predominates in the high heat flux region of the engine during high power level operation.

  3. Transient nucleation in condensed systems

    NASA Technical Reports Server (NTRS)

    Kelton, K. F.; Greer, A. L.; Thompson, C. V.

    1983-01-01

    Using classical nucleation theory we consider transient nucleation occurring in a one-component, condensed system under isothermal conditions. We obtain an exact closed-form expression for the time dependent cluster populations. In addition, a more versatile approach is developed: a numerical simulation technique which models directly the reactions by which clusters are produced. This simulation demonstrates the evolution of cluster populations and nucleation rate in the transient regime. Results from the simulation are verified by comparison with exact analytical solutions for the steady state. Experimental methods for measuring transient nucleation are assessed, and it is demonstrated that the observed behavior depends on the method used. The effect of preexisting cluster distributions is studied. Previous analytical and numerical treatments of transient nucleation are compared to the solutions obtained from the simulation. The simple expressions of Kashchiev are shown to give good descriptions of the nucleation behavior.

  4. Direct evaporative cooling of 39K atoms to Bose-Einstein condensation

    NASA Astrophysics Data System (ADS)

    Landini, M.; Roy, S.; Roati, G.; Simoni, A.; Inguscio, M.; Modugno, G.; Fattori, M.

    2012-09-01

    We report the realization of a Bose-Einstein condensate of 39K atoms without the aid of an additional atomic coolant. Our route to Bose-Einstein condensation comprises sub-Doppler laser cooling of large atomic clouds with more than 1010 atoms and evaporative cooling in an optical dipole trap where the collisional cross section can be increased using magnetic Feshbach resonances. Large condensates with almost 106 atoms can be produced in less than 15 s. Our achievements eliminate the need for sympathetic cooling with Rb atoms, which was the usual route implemented until now due to the unfavorable collisional property of 39K. Our findings simplify the experimental setup for producing Bose-Einstein condensates of 39K atoms with tunable interactions, which have a wide variety of promising applications, including atom interferometry to studies on the interplay of disorder and interactions in quantum gases.

  5. Emergency core cooling system

    DOEpatents

    Schenewerk, William E.; Glasgow, Lyle E.

    1983-01-01

    A liquid metal cooled fast breeder reactor provided with an emergency core cooling system includes a reactor vessel which contains a reactor core comprising an array of fuel assemblies and a plurality of blanket assemblies. The reactor core is immersed in a pool of liquid metal coolant. The reactor also includes a primary coolant system comprising a pump and conduits for circulating liquid metal coolant to the reactor core and through the fuel and blanket assemblies of the core. A converging-diverging venturi nozzle with an intermediate throat section is provided in between the assemblies and the pump. The intermediate throat section of the nozzle is provided with at least one opening which is in fluid communication with the pool of liquid sodium. In normal operation, coolant flows from the pump through the nozzle to the assemblies with very little fluid flowing through the opening in the throat. However, when the pump is not running, residual heat in the core causes fluid from the pool to flow through the opening in the throat of the nozzle and outwardly through the nozzle to the assemblies, thus providing a means of removing decay heat.

  6. Optimization of evaporative cooling towards a large number of Bose-Einstein-condensed atoms

    SciTech Connect

    Yamashita, Makoto; Mukai, Tetsuya; Mukai, Takaaki; Koashi, Masato; Mitsunaga, Masaharu; Imoto, Nobuyuki

    2003-02-01

    We study the optimization of evaporative cooling in trapped bosonic atoms on the basis of quantum kinetic theory of a Bose gas. The optimized cooling trajectory for {sup 87}Rb atoms indicates that the acceleration of evaporative cooling around the transition point of Bose-Einstein condensation is very effective against loss of trapped atoms caused by three-body recombination. The number of condensed atoms is largely enhanced by the optimization, more than two orders of magnitude in our present calculation using relevant experimental parameters, as compared with the typical value given by the conventional evaporative cooling where the frequency of radio-frequency magnetic field is swept exponentially. In addition to this optimized cooling, it is also shown that highly efficient evaporative cooling can be achieved by an initial exponential and then a rapid linear sweep of frequency.

  7. Liquid metal cooled nuclear reactors with passive cooling system

    DOEpatents

    Hunsbedt, Anstein; Fanning, Alan W.

    1991-01-01

    A liquid metal cooled nuclear reactor having a passive cooling system for removing residual heat resulting from fuel decay during reactor shutdown. The passive cooling system comprises a plurality of cooling medium flow circuits which cooperate to remove and carry heat away from the fuel core upon loss of the normal cooling flow circuit to areas external thereto.

  8. Heating and cooling system

    SciTech Connect

    Imig, L.A.; Gardner, M.R.

    1982-08-01

    A heating and cooling apparatus capable of cyclic heating and cooling of a test specimen undergoing fatigue testing is discussed. Cryogenic fluid is passed through a block clamped to the speciment to cool the block and the specimen. Heating cartridges penetrate the block to heat the block and the specimen to very hot temperaures. Control apparatus is provided to alternatively activate the cooling and heating modes to effect cyclic heating and cooling between very hot and very cold temperatures. The block is constructed of minimal mass to facilitate the rapid temperature changes. Official Gazette of the U.S. Patent and Trademark Office.

  9. Growth dynamics of a Bose-Einstein condensate in a dimple trap without cooling

    SciTech Connect

    Garrett, Michael C.; Davis, Matthew J.; Ratnapala, Adrian; Ooijen, Eikbert D. van; Vale, Christopher J.; Weegink, Kristian; Schnelle, Sebastian K.; Vainio, Otto; Heckenberg, Norman R.; Rubinsztein-Dunlop, Halina

    2011-01-15

    We study the formation of a Bose-Einstein condensate in a cigar-shaped three-dimensional harmonic trap, induced by the controlled addition of an attractive ''dimple'' potential along the weak axis. In this manner we are able to induce condensation without cooling due to a localized increase in the phase-space density. We perform a quantitative analysis of the thermodynamic transformation in both the sudden and adiabatic regimes for a range of dimple widths and depths. We find good agreement with equilibrium calculations based on self-consistent semiclassical Hartree-Fock theory describing the condensate and thermal cloud. We observe that there is an optimal dimple depth that results in a maximum in the condensate fraction. We also study the nonequilibrium dynamics of condensate formation in the sudden turn-on regime, finding good agreement for the observed time dependence of the condensate fraction with calculations based on quantum kinetic theory.

  10. Floating Loop System For Cooling Integrated Motors And Inverters Using Hot Liquid Refrigerant

    DOEpatents

    Hsu, John S [Oak Ridge, TN; Ayers, Curtis W [Kingston, TN; Coomer, Chester [Knoxville, TN; Marlino, Laura D [Oak Ridge, TN

    2006-02-07

    A floating loop vehicle component cooling and air-conditioning system having at least one compressor for compressing cool vapor refrigerant into hot vapor refrigerant; at least one condenser for condensing the hot vapor refrigerant into hot liquid refrigerant by exchanging heat with outdoor air; at least one floating loop component cooling device for evaporating the hot liquid refrigerant into hot vapor refrigerant; at least one expansion device for expanding the hot liquid refrigerant into cool liquid refrigerant; at least one air conditioning evaporator for evaporating the cool liquid refrigerant into cool vapor refrigerant by exchanging heat with indoor air; and piping for interconnecting components of the cooling and air conditioning system.

  11. Automotive Cooling and Lubricating Systems.

    ERIC Educational Resources Information Center

    Marine Corps Inst., Washington, DC.

    This correspondence course, originally developed for the Marine Corps, is designed to provide new mechanics with a source of study materials to assist them in becoming more proficient in their jobs. The course contains four study units covering automotive cooling system maintenance, cooling system repair, lubricating systems, and lubrication…

  12. Experiences in solar cooling systems

    NASA Astrophysics Data System (ADS)

    Ward, D. S.

    The results of performance evaluations for nine solar cooling systems are presented, and reasons fow low or high net energy balances are discussed. Six of the nine systems are noted to have performed unfavorably compared to standard cooling systems due to thermal storage losses, excessive system electrical demands, inappropriate control strategies, poor system-to-load matching, and poor chiller performance. A reduction in heat losses in one residential unit increased the total system efficiency by 2.5%, while eliminating heat losses to the building interior increased the efficiency by 3.3%. The best system incorporated a lithium bromide absorption chiller and a Rankine cycle compression unit for a commercial application. Improvements in the cooling tower and fan configurations to increase the solar cooling system efficiency are indicated. Best performances are expected to occur in climates inducing high annual cooling loads.

  13. Direct condensation refrigerant recovery and restoration system

    SciTech Connect

    Grant, D.C.H.

    1992-03-10

    This patent describes a refrigerant recovery and purification system for removing gaseous refrigerant from a disabled refrigeration unit, cleaning the refrigerant of contaminants, and converting the gaseous refrigerant to a liquid state for storage. It comprises a low pressure inlet section; a high pressure storage section; the low pressure inlet section comprising: an oil and refrigerant gas separator, including a separated oil removal means, first conduit means for connecting an inlet of the separator to the disabled refrigerant unit, a slack-sided accumulator, second conduit means connecting the separator to the slack-sided accumulator, a reclaim condenser, third conduit means connecting the separator and the reclaim condenser in series, an evaporator coil in the reclaim condenser connectable to a conventional operating refrigeration system for receiving a liquid refrigerant under pressure for expansion therein, the evaporator coil forming a condensing surface for condensing the refrigerant gas at near atmospheric pressure in the condenser, a liquid receiver, a reclaimed refrigerant storage tank, fourth conduit means further connecting the liquid receiver in series with the reclaim condenser, downstream thereof, means between the reclaim condenser and the liquid receiver.

  14. Infrared applications for steam turbine condenser systems

    NASA Astrophysics Data System (ADS)

    Lanius, Mark A.

    2000-03-01

    Infrared inspection of the main steam condensers at the Peach Bottom Atomic Power Station has been utilized successfully in detecting condenser air in-leakage problems. Air in-leakage lowers the condenser's vacuum, thus decreasing the condenser's efficiency. This creates backpressure on the turbine which lowers its efficiency, resulting in fewer megawatts generated. Air in-leakage also creates an increase in off-gas flow which is a radiological concern for both the plant and the public. Inspections are normally performed on the condenser's manway covers and rupture disks prior to an outage during coast down and post outage. The optimum conditions are 100% power and temperature, however, a high radiation field prevents the inspection until reactor power is down to 65% or less. Anomalies are typically indicated by cooling in the effected areas of the air in-leakage. The anomalies are not limited to air in-leakage. Intermittent water out-leakage, due to a heater dump valve cycling, has been detected when visual inspections field nothing.

  15. Combustor liner cooling system

    DOEpatents

    Lacy, Benjamin Paul; Berkman, Mert Enis

    2013-08-06

    A combustor liner is disclosed. The combustor liner includes an upstream portion, a downstream end portion extending from the upstream portion along a generally longitudinal axis, and a cover layer associated with an inner surface of the downstream end portion. The downstream end portion includes the inner surface and an outer surface, the inner surface defining a plurality of microchannels. The downstream end portion further defines a plurality of passages extending between the inner surface and the outer surface. The plurality of microchannels are fluidly connected to the plurality of passages, and are configured to flow a cooling medium therethrough, cooling the combustor liner.

  16. 46 CFR 153.432 - Cooling systems.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 5 2011-10-01 2011-10-01 false Cooling systems. 153.432 Section 153.432 Shipping COAST... Control Systems § 153.432 Cooling systems. (a) Each cargo cooling system must have an equivalent standby... cooling system. (b) Each tankship that has a cargo tank with a required cooling system must have a...

  17. 46 CFR 153.432 - Cooling systems.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 5 2010-10-01 2010-10-01 false Cooling systems. 153.432 Section 153.432 Shipping COAST... Control Systems § 153.432 Cooling systems. (a) Each cargo cooling system must have an equivalent standby... cooling system. (b) Each tankship that has a cargo tank with a required cooling system must have a...

  18. Design evaluation of an improved indirect evaporative cooling system

    NASA Astrophysics Data System (ADS)

    Dunn, J. R.

    1982-04-01

    The results of an investigation of an improved indirect evaporative cooling (TRC) system are presented. A cooling system concept which combines an indirect evaporative cooling unit with a conventional vapor compression refrigeration system was studied. In this system, initial cooling of outside air is performed in the IEC unit with additional cooling taking place across the evaporator coil of the conventional refrigeration unit before delivery to the conditioned space. The condenser coil rejects heat to the secondary (humidified) air stream of the IEC before it is discharged outdoors. A simulation model was developed to predict the performance characteristics of the concept for additional conditions beyond those used in the experimental test program. Principal output parameters from both the test program and simulation model included delivery air temperature, cooling capacity, and system COP.

  19. Temperature initiated passive cooling system

    DOEpatents

    Forsberg, C.W.

    1994-11-01

    A passive cooling system for cooling an enclosure only when the enclosure temperature exceeds a maximum standby temperature comprises a passive heat transfer loop containing heat transfer fluid having a particular thermodynamic critical point temperature just above the maximum standby temperature. An upper portion of the heat transfer loop is insulated to prevent two phase operation below the maximum standby temperature. 1 fig.

  20. Temperature initiated passive cooling system

    DOEpatents

    Forsberg, Charles W.

    1994-01-01

    A passive cooling system for cooling an enclosure only when the enclosure temperature exceeds a maximum standby temperature comprises a passive heat transfer loop containing heat transfer fluid having a particular thermodynamic critical point temperature just above the maximum standby temperature. An upper portion of the heat transfer loop is insulated to prevent two phase operation below the maximum standby temperature.

  1. Passive System Reliability Analysis: A Study on the Isolation Condenser

    SciTech Connect

    Burgazzi, Luciano

    2002-07-15

    This paper deals with the reliability assessment of passive systems that have been developed in recent years by suppliers, industries, utilities, and research organizations, aimed at plant safety improvement and substantial simplification in its implementation. The present study concerns the passive decay heat removal systems that use, for the most part, a condenser immersed in a cooling pool. The focus of the paper is a reliability study of the isolation condenser system foreseen for advanced boiling water reactors (BWRs) for the removal of the excess sensible and core decay heat from the BWR by natural circulation. Furthermore, an approach aimed at the thermal-hydraulic performance assessment (i.e., the natural circulation failure evaluation) from the probability point of view is given. The study is not plant-specific-related but pertains to the conceptual design of the foregoing system.

  2. Superconducting magnet cooling system

    DOEpatents

    Vander Arend, Peter C.; Fowler, William B.

    1977-01-01

    A device is provided for cooling a conductor to the superconducting state. The conductor is positioned within an inner conduit through which is flowing a supercooled liquid coolant in physical contact with the conductor. The inner conduit is positioned within an outer conduit so that an annular open space is formed therebetween. Through the annular space is flowing coolant in the boiling liquid state. Heat generated by the conductor is transferred by convection within the supercooled liquid coolant to the inner wall of the inner conduit and then is removed by the boiling liquid coolant, making the heat removal from the conductor relatively independent of conductor length.

  3. MINIATURE ACID CONDENSATION SYSTEM: DESIGN AND OPERATION

    EPA Science Inventory

    An extractive source sampling system was designed and constructed. The sampling system measures gaseous sulfuric acid and sulfur dioxide in combustion emissions. The miniature acid condensation system (MACS) includes a high-temperature quartz probe and quartz-filter holder. Since...

  4. Non-intrusive cooling system

    DOEpatents

    Morrison, Edward F.; Bergman, John W.

    2001-05-22

    A readily replaceable heat exchange cooling jacket for applying fluid to a system conduit pipe. The cooling jacket comprises at least two members, separable into upper and lower portions. A chamber is formed between the conduit pipe and cooling jacket once the members are positioned about the pipe. The upper portion includes a fluid spray means positioned above the pipe and the bottom portion includes a fluid removal means. The heat exchange cooling jacket is adaptable with a drain tank, a heat exchanger, a pump and other standard equipment to provide a system for removing heat from a pipe. A method to remove heat from a pipe, includes the steps of enclosing a portion of the pipe with a jacket to form a chamber between an outside surface of the pipe and the cooling jacket; spraying cooling fluid at low pressure from an upper portion of the cooling jacket, allowing the fluid to flow downwardly by gravity along the surface of the pipe toward a bottom portion of the chamber; and removing the fluid at the bottom portion of the chamber.

  5. Reduction of helium loss from a superconducting accelerating cavity during initial cool-down and cryostat exchange by pre-cooling the re-condensing cryostat

    NASA Astrophysics Data System (ADS)

    O'Rourke, B. E.; Minehara, E. J.; Hayashizaki, N.; Oshima, N.; Suzuki, R.

    2015-03-01

    A Zero-Boil-Off (ZBO) cryostat is designed to realize a compact, stand-alone cryogenic system for the AIST superconducting accelerator (SCA). Under normal operation there is no evaporative helium loss from the cryomodule and therefore operating costs associated with the supply of liquid helium can be eliminated. The only significant loss of helium from the module occurs during the initial cavity cool-down procedure or when the re-condensing cryostat is replaced. It takes about 3 h to cool down the cryostat head from room temperature (300 K) to 4 K. During this time around 100 L of liquid helium is lost due to evaporation. By pre-cooling the cryostat inside a low heat load vacuum tube before transfer to the cryomodule, this evaporative loss could be essentially eliminated, significantly reducing the volume of liquid helium required for the initial cryomodule cool-down. The pre-cooling system also provides an efficient method to test the cryostat prior to use.

  6. 242-A evaporator vacuum condenser system

    SciTech Connect

    Smith, V.A.

    1994-09-28

    This document is written for the 242-A evaporator vacuum condenser system (VCS), describing its purpose and operation within the evaporator. The document establishes the operating parameters specifying pressure, temperature, flow rates, interlock safety features and interfacing sub-systems to support its operation.

  7. Closed cycle desiccant cooling system

    NASA Astrophysics Data System (ADS)

    Tchernev, D. I.; Emerson, D. T.

    1986-10-01

    The breadboard prototype of a closed cycle desiccant cooling system was designed, constructed and its performance tested. The system combines the sorption properties of solid zeolite/refrigerant vapor pairs with the principle of regenerative heat exchangers. Since solid zeolites are difficult to move in vacuum tight containers and in order to avoid intermittent operation, the desiccant is housed in two separate containers which are alternately heated and cooled by a heat transfer fluid. Using the principle of energy regeneration, the heat removed from the container being cooled is recycled in the container being heated. The breadboard system, with 90 pounds of zeolite, demonstrated a recycling efficiency of 75%, while the system capacity was 2,000 Btu/hr. This significantly increased the system thermal Coefficient of Performance (COP) to 1.1 at ARI conditions from the single container thermal COP of 0.4.

  8. ENVIRONMENTAL TECHNOLOGY VERIFICATION REPORT: NEW CONDENSATOR, INC.--THE CONDENSATOR DIESEL ENGINE RETROFIT CRANKCASE VENTILATION SYSTEM

    EPA Science Inventory

    EPA's Environmental Technology Verification Program has tested New Condensator Inc.'s Condensator Diesel Engine Retrofit Crankcase Ventilation System. Brake specific fuel consumption (BSFC), the ratio of engine fuel consumption to the engine power output, was evaluated for engine...

  9. Bose-Einstein condensation of {sup 88}Sr through sympathetic cooling with {sup 87}Sr

    SciTech Connect

    Mickelson, P. G.; Martinez de Escobar, Y. N.; Yan, M.; DeSalvo, B. J.; Killian, T. C.

    2010-05-15

    We report Bose-Einstein condensation of {sup 88}Sr, which has a small, negative s-wave scattering length (a{sub 88}=-2a{sub 0}). We overcome the poor evaporative cooling characteristics of this isotope by sympathetic cooling with {sup 87}Sr atoms. {sup 87}Sr is effective in this role despite the fact that it is a fermion because of the large ground-state degeneracy arising from a nuclear spin of I=9/2, which reduces the impact of Pauli blocking of collisions. We observe a limited number of atoms in the condensate (N{sub max{approx_equal}}10{sup 4}) that is consistent with the value of a{sub 88} and the optical dipole trap parameters.

  10. Effect of weak interaction on kaon condensation and cooling of neutron stars.

    NASA Astrophysics Data System (ADS)

    Fujii, H.; Muto, T.; Tatsumi, T.; Tamagaki, R.

    1994-05-01

    Kaon condensation and its implication in the cooling mechanism in neutron stars are investigated within a framework of current algebra and PCAC. The weak interaction, nýp+K-, is shown to play a significant role in determining not only the critical density but also the equation of state of the K- condensed phase. The chemical equilibrium for the weak interaction leads to large proton-admixture. In connection with this result, the possibility of the direct URCA process, n→p+e-+ν¯e, p+e-→n+νe, is investigted. It is shown that, within a simple treatment without the nuclear interactions such as the symmetry energy, the kinematical condition for the direct URCA process is not satified despite the large proton-mixing, due to the resulting small electron Fermi momentum. The physical content of the K- condensation from a viewpoint of strangeness degrees of freedom is also discussed.

  11. Effects of weak interaction on kaon condensation and cooling of neutron stars

    NASA Astrophysics Data System (ADS)

    Hirotsugu, Fujii; Takumi, Muto; Toshitaka, Tatsumi; Ryozo, Tamagaki

    1994-05-01

    Kaon condensation and its implication in the cooling mechanism in neutron stars are investigated within a framework of current algebra and PCAC. The weak interaction, n ⇌ p + K -, is shown to play a significant role in determining not only the critical density but also the equation of state of the K - condensed phase. The chemical equilibrium for the weak interaction leads to large proton-admixture. In connection with this result, the possibility of the direct URCA process, n → p + e- + v¯e, p + e- → n + v e, is investigated. It is shown that, within a simple treatment without the nuclear interactions such as the symmetry energy, the kinematical condition for the direct URCA process is not satisfied despite the large proton-mixing, due to the resulting small electron Fermi momentum. The physical content of the K - condensation from a viewpoint of strangeness degrees of freedom is also discussed.

  12. Solar-powered cooling system

    DOEpatents

    Farmer, Joseph C

    2013-12-24

    A solar-powered adsorption-desorption refrigeration and air conditioning system uses nanostructural materials made of high specific surface area adsorption aerogel as the adsorptive media. Refrigerant molecules are adsorbed on the high surface area of the nanostructural material. A circulation system circulates refrigerant from the nanostructural material to a cooling unit.

  13. Compressor bleed cooling fluid feed system

    DOEpatents

    Donahoo, Eric E; Ross, Christopher W

    2014-11-25

    A compressor bleed cooling fluid feed system for a turbine engine for directing cooling fluids from a compressor to a turbine airfoil cooling system to supply cooling fluids to one or more airfoils of a rotor assembly is disclosed. The compressor bleed cooling fluid feed system may enable cooling fluids to be exhausted from a compressor exhaust plenum through a downstream compressor bleed collection chamber and into the turbine airfoil cooling system. As such, the suction created in the compressor exhaust plenum mitigates boundary layer growth along the inner surface while providing flow of cooling fluids to the turbine airfoils.

  14. Protected air-cooled condenser for the Clinch River Breeder Reactor Plant

    SciTech Connect

    Louison, R.; Boardman, C.E.

    1981-05-29

    The long term residual heat removal for the Clinch River Breeder Reactor Plant (CRBRP) is accomplished through the use of three protected air-cooled condensers (PACC's) each rated at 15M/sub t/ following a normal or emergency shutdown of the reactor. Steam is condensed by forcing air over the finned and coiled condenser tubes located above the steam drums. The steam flow is by natural convection. It is drawn to the PACC tube bundle for the steam drum by the lower pressure region in the tube bundle created from the condensing action. The concept of the tube bundle employs a unique patented configuration which has been commercially available through CONSECO Inc. of Medfore, Wisconsin. The concept provides semi-parallel flow that minimizes subcooling and reduces steam/condensate flow instabilities that have been observed on other similar heat transfer equipment such as moisture separator reheaters (MSRS). The improved flow stability will reduce temperature cycling and associated mechanical fatigue. The PACC is being designed to operate during and following the design basis earthquake, depressurization from the design basis tornado and is housed in protective building enclosure which is also designed to withstand the above mentioned events.

  15. Improved Performance of an Air Cooled Condenser (ACC) Using SPX Wind Guide Technology at Coal-Based Thermoelectric Power Plants

    SciTech Connect

    Ken Mortensen

    2010-12-31

    This project added a new airflow enhancement technology to an existing ACC cooling process at a selected coal power plant. Airflow parameters and efficiency improvement for the main plant cooling process using the applied technology were determined and compared with the capabilities of existing systems. The project required significant planning and pre-test execution in order to reach the required Air Cooled Condenser system configuration for evaluation. A host Power Plant ACC system had to be identified, agreement finalized, and addition of the SPX ACC Wind Guide Technology completed on that site. Design of the modification, along with procurement, fabrication, instrumentation, and installation of the new airflow enhancement technology were executed. Baseline and post-modification cooling system data was collected and evaluated. The improvement of ACC thermal performance after SPX wind guide installation was clear. Testing of the improvement indicates there is a 5% improvement in heat transfer coefficient in high wind conditions and 1% improvement at low wind speed. The benefit increased with increasing wind speed. This project was completed on schedule and within budget.

  16. Indirect passive cooling system for liquid metal cooled nuclear reactors

    DOEpatents

    Hunsbedt, Anstein; Boardman, Charles E.

    1990-01-01

    A liquid metal cooled nuclear reactor having a passive cooling system for removing residual heat resulting from fuel decay during reactor shutdown. The passive cooling system comprises a plurality of partitions surrounding the reactor vessel in spaced apart relation forming intermediate areas for circulating heat transferring fluid which remove and carry away heat from the reactor vessel. The passive cooling system includes a closed primary fluid circuit through the partitions surrounding the reactor vessel and a partially adjoining secondary open fluid circuit for carrying transferred heat out into the atmosphere.

  17. Passive cooling safety system for liquid metal cooled nuclear reactors

    DOEpatents

    Hunsbedt, Anstein; Boardman, Charles E.; Hui, Marvin M.; Berglund, Robert C.

    1991-01-01

    A liquid metal cooled nuclear reactor having a passive cooling system for removing residual heat resulting from fuel decay during reactor shutdown. The passive cooling system comprises a plurality of partitions surrounding the reactor vessel in spaced apart relation forming intermediate areas for circulating heat transferring fluid which remove and carry away heat from the reactor vessel. The passive cooling system includes a closed primary fluid circuit through the partitions surrounding the reactor vessel and a partially adjoining secondary open fluid circuit for carrying transferred heat out into the atmosphere.

  18. Condensate and feedwater systems, pumps, and water chemistry. Volume seven

    SciTech Connect

    Not Available

    1986-01-01

    Subject matter includes condensate and feedwater systems (general features of condensate and feedwater systems, condenser hotwell level control, condensate flow, feedwater flow), pumps (principles of fluid flow, types of pumps, centrifugal pumps, positive displacement pumps, jet pumps, pump operating characteristics) and water chemistry (water chemistry fundamentals, corrosion, scaling, radiochemistry, water chemistry control processes, water pretreatment, PWR water chemistry, BWR water chemistry, condenser circulating water chemistry.

  19. Cooling system for electronic components

    DOEpatents

    Anderl, William James; Colgan, Evan George; Gerken, James Dorance; Marroquin, Christopher Michael; Tian, Shurong

    2016-05-17

    Embodiments of the present invention provide for non interruptive fluid cooling of an electronic enclosure. One or more electronic component packages may be removable from a circuit card having a fluid flow system. When installed, the electronic component packages are coincident to and in a thermal relationship with the fluid flow system. If a particular electronic component package becomes non-functional, it may be removed from the electronic enclosure without affecting either the fluid flow system or other neighboring electronic component packages.

  20. Cooling system for electronic components

    SciTech Connect

    Anderl, William James; Colgan, Evan George; Gerken, James Dorance; Marroquin, Christopher Michael; Tian, Shurong

    2015-12-15

    Embodiments of the present invention provide for non interruptive fluid cooling of an electronic enclosure. One or more electronic component packages may be removable from a circuit card having a fluid flow system. When installed, the electronic component packages are coincident to and in a thermal relationship with the fluid flow system. If a particular electronic component package becomes non-functional, it may be removed from the electronic enclosure without affecting either the fluid flow system or other neighboring electronic component packages.

  1. Gas hydrate cool storage system

    DOEpatents

    Ternes, M.P.; Kedl, R.J.

    1984-09-12

    The invention presented relates to the development of a process utilizing a gas hydrate as a cool storage medium for alleviating electric load demands during peak usage periods. Several objectives of the invention are mentioned concerning the formation of the gas hydrate as storage material in a thermal energy storage system within a heat pump cycle system. The gas hydrate was formed using a refrigerant in water and an example with R-12 refrigerant is included. (BCS)

  2. Interim Report: Air-Cooled Condensers for Next Generation Geothermal Power Plants Improved Binary Cycle Performance

    SciTech Connect

    Daniel S. Wendt; Greg L. Mines

    2010-09-01

    As geothermal resources that are more expensive to develop are utilized for power generation, there will be increased incentive to use more efficient power plants. This is expected to be the case with Enhanced Geothermal System (EGS) resources. These resources will likely require wells drilled to depths greater than encountered with hydrothermal resources, and will have the added costs for stimulation to create the subsurface reservoir. It is postulated that plants generating power from these resources will likely utilize the binary cycle technology where heat is rejected sensibly to the ambient. The consumptive use of a portion of the produced geothermal fluid for evaporative heat rejection in the conventional flash-steam conversion cycle is likely to preclude its use with EGS resources. This will be especially true in those areas where there is a high demand for finite supplies of water. Though they have no consumptive use of water, using air-cooling systems for heat rejection has disadvantages. These systems have higher capital costs, reduced power output (heat is rejected at the higher dry-bulb temperature), increased parasitics (fan power), and greater variability in power generation on both a diurnal and annual basis (larger variation in the dry-bulb temperature). This is an interim report for the task ‘Air-Cooled Condensers in Next- Generation Conversion Systems’. The work performed was specifically aimed at a plant that uses commercially available binary cycle technologies with an EGS resource. Concepts were evaluated that have the potential to increase performance, lower cost, or mitigate the adverse effects of off-design operation. The impact on both cost and performance were determined for the concepts considered, and the scenarios identified where a particular concept is best suited. Most, but not all, of the concepts evaluated are associated with the rejection of heat. This report specifically addresses three of the concepts evaluated: the use of

  3. All-optical cooling of K39 to Bose-Einstein condensation

    NASA Astrophysics Data System (ADS)

    Salomon, G.; Fouché, L.; Lepoutre, S.; Aspect, A.; Bourdel, T.

    2014-09-01

    We report the all-optical production of Bose-Einstein condensates (BEC) of K39 atoms. We directly load 3×107 atoms in a large volume optical dipole trap from gray molasses on the D1 transition. We then apply a small magnetic quadrupole field to polarize the sample before transferring the atoms in a tightly confining optical trap. Evaporative cooling is finally performed close to a Feshbach resonance to enhance the scattering length. Our setup allows one to cross the BEC threshold with 3×105 atoms every 7 s. As an illustration of the interest of the tunability of the interactions we study the expansion of Bose-Einstein condensates in the one-dimensional to three-dimensional crossover.

  4. Mitigation of biofouling using electromagnetic fields in tubular heat exchangers-condensers cooled by seawater.

    PubMed

    Trueba, Alfredo; García, Sergio; Otero, Félix M

    2014-01-01

    Electromagnetic field (EMF) treatment is presented as an alternative physical treatment for the mitigation of biofouling adhered to the tubes of a heat exchanger-condenser cooled by seawater. During an experimental phase, a fouling biofilm was allowed to grow until experimental variables indicated that its growth had stabilised. Subsequently, EMF treatment was applied to seawater to eliminate the biofilm and to maintain the achieved cleanliness. The results showed that EMFs precipitated ions dissolved in the seawater. As a consequence of the application of EMFs, erosion altered the intermolecular bonding of extracellular polymers, causing the destruction of the biofilm matrix and its detachment from the inner surface of the heat exchanger-condenser tubes. This detachment led to the partial removal of a mature biofilm and a partial recovery of the efficiency lost in the heat transfer process by using a physical treatment that is harmless to the marine environment. PMID:24266611

  5. System Study: Isolation Condenser 1998-2014

    SciTech Connect

    Schroeder, John Alton

    2015-12-01

    This report presents an unreliability evaluation of the isolation condenser (ISO) system at four U.S. boiling water reactors. Demand, run hours, and failure data from fiscal year 1998 through 2014 for selected components were obtained from the Institute of Nuclear Power Operations (INPO) Consolidated Events Database (ICES). The unreliability results are trended for the most recent 10 year period, while yearly estimates for system unreliability are provided for the entire active period. No statistically significant increasing trends were identified. A statistically significant decreasing trend was identified for ISO unreliability. The magnitude of the trend indicated a 1.5 percent decrease in system unreliability over the last 10 years.

  6. Cooling systems for satellite remote sensing instrumentation

    NASA Technical Reports Server (NTRS)

    Copeland, R. J.; Oren, J. A.

    1974-01-01

    The characteristics of a cryogenic cooling system for the Pollution Monitoring Satellite (PMS) are discussed. Studies were conducted to make the following determinations: (1) the characteristics and use of proven and state-of-the-art cryogenic cooling systems for six specified ranges of performance, (2) the system most applicable for each of the six cooling categories, and (3) conceptual designs for candidate system for each of the six representative cooling categories. The six cooling categories of electrical loads are defined. The desired mission life for the cooling system is two years with both continuous and intermittent operating conditions.

  7. Information technology equipment cooling system

    DOEpatents

    Schultz, Mark D.

    2014-06-10

    According to one embodiment, a system for removing heat from a rack of information technology equipment may include a sidecar indoor air to liquid heat exchanger that cools warm air generated by the rack of information technology equipment. The system may also include a liquid to liquid heat exchanger and an outdoor heat exchanger. The system may further include configurable pathways to connect and control fluid flow through the sidecar heat exchanger, the liquid to liquid heat exchanger, the rack of information technology equipment, and the outdoor heat exchanger based upon ambient temperature and/or ambient humidity to remove heat from the rack of information technology equipment.

  8. Conceptual Design of a Condensing Heat Exchanger for Space Systems Using Porous Media

    NASA Technical Reports Server (NTRS)

    Hasan, Mohammad M.; Khan, Lutful I.; Nayagam, Vedha; Balasubramaniam, Ramaswamy

    2006-01-01

    Condensing heat exchangers are used in many space applications in the thermal and humidity control systems. In the International Space Station (ISS), humidity control is achieved by using a water cooled fin surface over which the moist air condenses, followed by "slurper bars" that take in both the condensate and air into a rotary separator and separates the water from air. The use of a cooled porous substrate as the condensing surface provides and attractive alternative that combines both heat removal as well as liquid/gas separation into a single unit. By selecting the pore sizes of the porous substrate a gravity independent operation may also be possible with this concept. Condensation of vapor into and on the porous surface from the flowing air and the removal of condensate from the porous substrate are the critical processes involved in the proposed concept. This paper describes some preliminary results of the proposed condensate withdrawal process and discusses the on-going design and development work of a porous media based condensing heat exchanger at the NASA Glenn Research Center in collaboration with NASA Johnson Space Center.

  9. Cooling system for superconducting magnet

    DOEpatents

    Gamble, B.B.; Sidi-Yekhlef, A.

    1998-12-15

    A cooling system is configured to control the flow of a refrigerant by controlling the rate at which the refrigerant is heated, thereby providing an efficient and reliable approach to cooling a load (e.g., magnets, rotors). The cooling system includes a conduit circuit connected to the load and within which a refrigerant circulates; a heat exchanger, connected within the conduit circuit and disposed remotely from the load; a first and a second reservoir, each connected within the conduit, each holding at least a portion of the refrigerant; a heater configured to independently heat the first and second reservoirs. In a first mode, the heater heats the first reservoir, thereby causing the refrigerant to flow from the first reservoir through the load and heat exchanger, via the conduit circuit and into the second reservoir. In a second mode, the heater heats the second reservoir to cause the refrigerant to flow from the second reservoir through the load and heat exchanger via the conduit circuit and into the first reservoir. 3 figs.

  10. Cooling system for superconducting magnet

    DOEpatents

    Gamble, Bruce B.; Sidi-Yekhlef, Ahmed

    1998-01-01

    A cooling system is configured to control the flow of a refrigerant by controlling the rate at which the refrigerant is heated, thereby providing an efficient and reliable approach to cooling a load (e.g., magnets, rotors). The cooling system includes a conduit circuit connected to the load and within which a refrigerant circulates; a heat exchanger, connected within the conduit circuit and disposed remotely from the load; a first and a second reservoir, each connected within the conduit, each holding at least a portion of the refrigerant; a heater configured to independently heat the first and second reservoirs. In a first mode, the heater heats the first reservoir, thereby causing the refrigerant to flow from the first reservoir through the load and heat exchanger, via the conduit circuit and into the second reservoir. In a second mode, the heater heats the second reservoir to cause the refrigerant to flow from the second reservoir through the load and heat exchanger via the conduit circuit and into the first reservoir.

  11. System Study: Isolation Condenser 1998–2013

    SciTech Connect

    Schroeder, John Alton

    2015-01-31

    This report presents an unreliability evaluation of the isolation condenser (ISO) system at four U.S. boiling water reactors. Demand, run hours, and failure data from fiscal year 1998 through 2013 for selected components were obtained from the Institute of Nuclear Power Operations (INPO) Consolidated Events Database (ICES). The unreliability results are trended for the most recent 10-year period, while yearly estimates for system unreliability are provided for the entire active period. No statistically significant increasing or decreasing trends were identified in the ISO results.

  12. Vehicle hydraulic cooling fan system

    SciTech Connect

    Nilson, C.A.

    1993-06-08

    A hydraulic cooling system for vehicles having an internal combustion engine cooled by a radiator and a coolant is described, comprising, in combination, a shroud adapted to be mounted adjacent the radiator having a wall forming an air passage and defining a first port disposed adjacent the radiator and a second port spaced from the first port, a fan located within the second port, a hydraulic fan motor operatively connected to the fan, a hydraulic pump operatively connected to the engine for producing a pressurized hydraulic fluid flow, a hydraulic circuit interconnecting the pump to the fan motor, the circuit including a control valve, a hydraulic fluid reservoir and a heat exchanger, the heat exchanger being mounted within the shroud air passage.

  13. Influence mechanism on flow and heat transfer characteristics for air-cooled steam condenser cells

    NASA Astrophysics Data System (ADS)

    He, Wei Feng; Dai, Yi Ping; Li, Mao Qing; Ma, Qing Zhong

    2012-09-01

    Air-cooled steam condensers (ACSCs) have been extensively utilized to reject waste heat in power industry to save water resources. However, ACSC performance is so sensitive to ambient wind that almost all the air-cooled power plants in China are less efficient compared to design conditions. It is shown from previous research that the influence of ambient wind on the cell performance differs from its location in the condenser. As a result, a numerical model including two identical ACSC cells are established, and the different influence on the performance of the cells is demonstrated and analyzed through the computational fluid dynamics method. Despite the great influence from the wind speeds, similar cell performance is obtained for the two cells under both windless and wind speed conditions when the wind parallels to the steam duct. Fan volumetric effectiveness which characterizes the fan performance, as well as the exchanger heat transfer rate, drops obviously with the increasing wind speed, and performance difference between the exchanger pair in the same A-frame also rises continuously. Furthermore, different flow and heat transfer characteristics of the windward and leeward cell are obtained at different wind angles, and ambient wind enhances the performance of the leeward cell, while that of the windward one changes little.

  14. Fossilized condensation lines in the Solar System protoplanetary disk

    NASA Astrophysics Data System (ADS)

    Morbidelli, A.; Bitsch, B.; Crida, A.; Gounelle, M.; Guillot, T.; Jacobson, S.; Johansen, A.; Lambrechts, M.; Lega, E.

    2016-03-01

    The terrestrial planets and the asteroids dominant in the inner asteroid belt are water poor. However, in the protoplanetary disk the temperature should have decreased below water-condensation level well before the disk was photo-evaporated. Thus, the global water depletion of the inner Solar System is puzzling. We show that, even if the inner disk becomes cold, there cannot be direct condensation of water. This is because the snowline moves towards the Sun more slowly than the gas itself. Thus the gas in the vicinity of the snowline always comes from farther out, where it should have already condensed, and therefore it should be dry. The appearance of ice in a range of heliocentric distances swept by the snowline can only be due to the radial drift of icy particles from the outer disk. However, if a planet with a mass larger than 20 Earth mass is present, the radial drift of particles is interrupted, because such a planet gives the disk a super-Keplerian rotation just outside of its own orbit. From this result, we propose that the precursor of Jupiter achieved this threshold mass when the snowline was still around 3 AU. This effectively fossilized the snowline at that location. In fact, even if it cooled later, the disk inside of Jupiter's orbit remained ice-depleted because the flow of icy particles from the outer system was intercepted by the planet. This scenario predicts that planetary systems without giant planets should be much more rich in water in their inner regions than our system. We also show that the inner edge of the planetesimal disk at 0.7 AU, required in terrestrial planet formation models to explain the small mass of Mercury and the absence of planets inside of its orbit, could be due to the silicate condensation line, fossilized at the end of the phase of streaming instability that generated the planetesimal seeds. Thus, when the disk cooled, silicate particles started to drift inwards of 0.7 AU without being sublimated, but they could not be

  15. Reuse of pretreated coal gasification condensate in a pilot scale cooling tower

    SciTech Connect

    Johnson, M.D.; Schweitzer, G.W.

    1987-01-01

    The recycle of wastewaters to cooling water systems is practiced in many industrial sectors. The Great Plains Gasification Plant (GPGP) located near Beulah, North Dakota, for example, was designed to reuse treated gas liquor as the primary source of makeup water. In other industrial plants, the concentration of contaminants in the makeup water is very low or the wastewater comprises only a small fraction of the total makeup to the cooling system. The Great Plains system is unique in that the stripped gas liquor (SGL) used as makeup contains relatively high concentrations of dissolved organics, ammonia and acid gases. In addition, the SGL constitutes over 90% of the total makeup to the system. The use of pretreated gas liquor in open, circulating cooling systems is an untried approach to wastewater recycle. The plant not only eliminates a large discharge problem but gains a valuable makeup source for the cooling towers. Because of the large heat duties for the cooling system in these types of plants and their location of regions of water shortages, this approach can be very beneficial. However, there are several environmental and operational concerns that have yet to be resolved. These include atmospheric emissions, fouling of heat transfer surfaces and cooling tower equipment, and excessive corrosion of system components.

  16. Turbine airfoil with ambient cooling system

    DOEpatents

    Campbell, Jr, Christian X.; Marra, John J.; Marsh, Jan H.

    2016-06-07

    A turbine airfoil usable in a turbine engine and having at least one ambient air cooling system is disclosed. At least a portion of the cooling system may include one or more cooling channels configured to receive ambient air at about atmospheric pressure. The ambient air cooling system may have a tip static pressure to ambient pressure ratio of at least 0.5, and in at least one embodiment, may include a tip static pressure to ambient pressure ratio of between about 0.5 and about 3.0. The cooling system may also be configured such that an under root slot chamber in the root is large to minimize supply air velocity. One or more cooling channels of the ambient air cooling system may terminate at an outlet at the tip such that the outlet is aligned with inner surfaces forming the at least one cooling channel in the airfoil to facilitate high mass flow.

  17. Heat pump system with selective space cooling

    DOEpatents

    Pendergrass, Joseph C.

    1997-01-01

    A reversible heat pump provides multiple heating and cooling modes and includes a compressor, an evaporator and heat exchanger all interconnected and charged with refrigerant fluid. The heat exchanger includes tanks connected in series to the water supply and a condenser feed line with heat transfer sections connected in counterflow relationship. The heat pump has an accumulator and suction line for the refrigerant fluid upstream of the compressor. Sub-cool transfer tubes associated with the accumulator/suction line reclaim a portion of the heat from the heat exchanger. A reversing valve switches between heating/cooling modes. A first bypass is operative to direct the refrigerant fluid around the sub-cool transfer tubes in the space cooling only mode and during which an expansion valve is utilized upstream of the evaporator/indoor coil. A second bypass is provided around the expansion valve. A programmable microprocessor activates the first bypass in the cooling only mode and deactivates the second bypass, and vice-versa in the multiple heating modes for said heat exchanger. In the heating modes, the evaporator may include an auxiliary outdoor coil for direct supplemental heat dissipation into ambient air. In the multiple heating modes, the condensed refrigerant fluid is regulated by a flow control valve.

  18. Heat pump system with selective space cooling

    DOEpatents

    Pendergrass, J.C.

    1997-05-13

    A reversible heat pump provides multiple heating and cooling modes and includes a compressor, an evaporator and heat exchanger all interconnected and charged with refrigerant fluid. The heat exchanger includes tanks connected in series to the water supply and a condenser feed line with heat transfer sections connected in counterflow relationship. The heat pump has an accumulator and suction line for the refrigerant fluid upstream of the compressor. Sub-cool transfer tubes associated with the accumulator/suction line reclaim a portion of the heat from the heat exchanger. A reversing valve switches between heating/cooling modes. A first bypass is operative to direct the refrigerant fluid around the sub-cool transfer tubes in the space cooling only mode and during which an expansion valve is utilized upstream of the evaporator/indoor coil. A second bypass is provided around the expansion valve. A programmable microprocessor activates the first bypass in the cooling only mode and deactivates the second bypass, and vice-versa in the multiple heating modes for said heat exchanger. In the heating modes, the evaporator may include an auxiliary outdoor coil for direct supplemental heat dissipation into ambient air. In the multiple heating modes, the condensed refrigerant fluid is regulated by a flow control valve. 4 figs.

  19. Performance evaluation of an active solar cooling system utilizing low cost plastic collectors and an evaporatively-cooled absorption chiller

    NASA Astrophysics Data System (ADS)

    Lof, G. O.; Westhoff, M. A.; Karaki, S.

    1984-02-01

    During the summer of 1982, air conditioning in Solar House 3 at Colorado State University was provided by an evaporatively-cooled absorption chiller. The single-effect lithium bromide chiller is an experimental three-ton unit from which heat is rejected by direct evaporative cooling of the condenser and absorber walls, thereby eliminating the need for a separate cooling tower. Domestic hot water was also provided by use of a double-walled heat exchanger and 80-gal hot water tank. A schematic of the system is given. Objectives of the project were: (1) evaluation of system performance over the course of one cooling season in Fort Collins, Colorado; (2) optimization of system operation and control; (3) development of a TRNSYS compatible model of the chiller; and (4) determination of cooling system performance in several U.S. climates by use of the model.

  20. Vapor Compression and Thermoelectric Heat Pump Heat Exchangers for a Condensate Distillation System: Design and Experiment

    NASA Technical Reports Server (NTRS)

    Erickson, Lisa R.; Ungar, Eugene K.

    2013-01-01

    Maximizing the reuse of wastewater while minimizing the use of consumables is critical in long duration space exploration. One of the more promising methods of reclaiming urine is the distillation/condensation process used in the cascade distillation system (CDS). This system accepts a mixture of urine and toxic stabilizing agents, heats it to vaporize the water and condenses and cools the resulting water vapor. The CDS wastewater flow requires heating and its condensate flow requires cooling. Performing the heating and cooling processes separately requires two separate units, each of which would require large amounts of electrical power. By heating the wastewater and cooling the condensate in a single heat pump unit, mass, volume, and power efficiencies can be obtained. The present work describes and compares two competing heat pump methodologies that meet the needs of the CDS: 1) a series of mini compressor vapor compression cycles and 2) a thermoelectric heat exchanger. In the paper, the system level requirements are outlined, the designs of the two heat pumps are described in detail, and the results of heat pump performance tests are provided. A summary is provided of the heat pump mass, volume and power trades and a selection recommendation is made.

  1. Cool systems for hot cities

    SciTech Connect

    Akbari, Hashem; Bretz, Sarah

    1998-09-02

    On a hot summer day, Los Angeles, CA, like Baltimore, MD, Phoenix, AZ, Washington, D.C., and Tokyo, Japan, is c. 6-8 degrees F hotter than its surrounding areas. Dark buildings and pavement have replaced urban vegetation in these cities, absorbing more solar heat. The urban heat islands that are created result in increased air-conditioning costs, energy use, and pollution. Scientists at the Lawrence Berkeley National Laboratory have been studying the effects of roof system color and type on the energy used to cool a building. The results of this research indicate that roofing professionals should consider the reflectance (albedo) and emittance (release of absorbed heat) of the roof systems they install.

  2. Radiant vessel auxiliary cooling system

    DOEpatents

    Germer, John H.

    1987-01-01

    In a modular liquid-metal pool breeder reactor, a radiant vessel auxiliary cooling system is disclosed for removing the residual heat resulting from the shutdown of a reactor by a completely passive heat transfer system. A shell surrounds the reactor and containment vessel, separated from the containment vessel by an air passage. Natural circulation of air is provided by air vents at the lower and upper ends of the shell. Longitudinal, radial and inwardly extending fins extend from the shell into the air passage. The fins are heated by radiation from the containment vessel and convect the heat to the circulating air. Residual heat from the primary reactor vessel is transmitted from the reactor vessel through an inert gas plenum to a guard or containment vessel designed to contain any leaking coolant. The containment vessel is conventional and is surrounded by the shell.

  3. Heat exchanger with auxiliary cooling system

    DOEpatents

    Coleman, John H.

    1980-01-01

    A heat exchanger with an auxiliary cooling system capable of cooling a nuclear reactor should the normal cooling mechanism become inoperable. A cooling coil is disposed around vertical heat transfer tubes that carry secondary coolant therethrough and is located in a downward flow of primary coolant that passes in heat transfer relationship with both the cooling coil and the vertical heat transfer tubes. A third coolant is pumped through the cooling coil which absorbs heat from the primary coolant which increases the downward flow of the primary coolant thereby increasing the natural circulation of the primary coolant through the nuclear reactor.

  4. Computer model for air-cooled refrigerant condensers with specified refrigerant circuiting

    SciTech Connect

    Ellison, R.D.; Creswick, F.A.; Fischer, S.K.; Jackson, W.L.

    1981-01-01

    A computer model for an air-cooled refrigerant condensor is presented; the model is intended for use in detailed design analyses or in simulation of the performance of existing heat exchangers that have complex refrigerant circuiting or unusual air-side geometries. The model relies on a tube-by-tube computational approach calculating the thermal and fluid-flow performance of each tube in the heat exchanger individually, using local temperatures and heat transfer coefficients. The refrigerant circuiting must be specified; the joining or branching of parallel circuits is accommodated using appropriate mixing expressions. Air-side heat exchange correlations may be specified so that various surface geometries can be investigated. Results of the analyses of two condensers are compared to experiment.

  5. High temperature cooling system and method

    DOEpatents

    Loewen, Eric P.

    2006-12-12

    A method for cooling a heat source, a method for preventing chemical interaction between a vessel and a cooling composition therein, and a cooling system. The method for cooling employs a containment vessel with an oxidizable interior wall. The interior wall is oxidized to form an oxide barrier layer thereon, the cooling composition is monitored for excess oxidizing agent, and a reducing agent is provided to eliminate excess oxidation. The method for preventing chemical interaction between a vessel and a cooling composition involves introducing a sufficient quantity of a reactant which is reactive with the vessel in order to produce a barrier layer therein that is non-reactive with the cooling composition. The cooling system includes a containment vessel with oxidizing agent and reducing agent delivery conveyances and a monitor of oxidation and reduction states so that proper maintenance of a vessel wall oxidation layer occurs.

  6. A new cylinder cooling system using oil

    SciTech Connect

    Harashina, Kenichi; Murata, Katsuhiro; Satoh, Hiroshi; Shimizu, Yasuo; Hamamura, Masahiro

    1995-12-31

    The design of engine cylinders must satisfy two conflicting requirements, good cooling performance and ease of manufacture. A cooling system was designed to permit the circulation of engine lubricating oil as a coolant at high speed through grooves provided on the external periphery of the cylinder liner. Testing in an actual operating engine confirmed that this cooling system design not only provides better heat transfer and higher cooling performance but also simplifies the manufacturing of the cylinder since external cooling fins are not required. In this paper, the authors will discuss the cylinder cooling effect of the new cylinder cooling system, referring mainly to the test results of a single-cylinder motorcycle engine with lubricating oil from the crankcase used as the coolant.

  7. Passive cooling systems in residential buildings

    NASA Astrophysics Data System (ADS)

    Ingersoll, John G.; Givoni, Baruch

    1985-11-01

    The performance of four passive cooling systems, nocturnal convective cooling, nocturnal radiative cooling, direct evaporative cooling and conductive earth-coupled cooling, is evaluated for representative environmental conditions in the temperate, hot-humid and hot-arid climatic zones of the United States. The analysis indicates that substantial portion of the cooling load of a typical energy-efficient single family residential building can be eliminated with any of these passive systems. Depending on system type and climatic zone, the building cooling load can be reduced by 1/3 to over 4/5 of its original value. The corresponding energy savings would amount to a minimum of 25 TWh/yr and could potentially exceed 50 TWh/yr, if proper passive cooling systems were to be employed throughout the country. Incorporation of passive cooling models in building energy analysis codes will be necessary to determine more precisely the potential of each system. Field testing will also be required to further evaluate this potential. Moreover, the extension of analytical modeling to include additional passive cooling systems and the research of advanced building—natural environment coupling systems and materials constitute tasks requiring further effort.

  8. Quantum entanglement in condensed matter systems

    NASA Astrophysics Data System (ADS)

    Laflorencie, Nicolas

    2016-08-01

    This review focuses on the field of quantum entanglement applied to condensed matter physics systems with strong correlations, a domain which has rapidly grown over the last decade. By tracing out part of the degrees of freedom of correlated quantum systems, useful and non-trivial information can be obtained through the study of the reduced density matrix, whose eigenvalue spectrum (the entanglement spectrum) and the associated Rényi entropies are now well recognized to contain key features. In particular, the celebrated area law for the entanglement entropy of ground-states will be discussed from the perspective of its subleading corrections which encode universal details of various quantum states of matter, e.g. symmetry breaking states or topological order. Going beyond entropies, the study of the low-lying part of the entanglement spectrum also allows to diagnose topological properties or give a direct access to the excitation spectrum of the edges, and may also raise significant questions about the underlying entanglement Hamiltonian. All these powerful tools can be further applied to shed some light on disordered quantum systems where impurity/disorder can conspire with quantum fluctuations to induce non-trivial effects. Disordered quantum spin systems, the Kondo effect, or the many-body localization problem, which have all been successfully (re)visited through the prism of quantum entanglement, will be discussed in detail. Finally, the issue of experimental access to entanglement measurement will be addressed, together with its most recent developments.

  9. Rankine-cycle heating and cooling systems

    NASA Technical Reports Server (NTRS)

    1979-01-01

    Design for domestic or commercial solar heating and cooling system based on rankine heat pump cycle includes detailed drawings, performance data, equipment specifications, and other pertinent information.

  10. Report on Preliminary Engineering Study for Installation of an Air Cooled Steam Condenser at Brawley Geothermal Plant, Unit No. 1

    SciTech Connect

    1982-03-01

    The Brawley Geothermal Project comprises a single 10 MW nominal geothermal steam turbine-generator unit which has been constructed and operated by the Southern California Edison Company (SCE). Geothermal steam for the unit is supplied through contract by Union Oil Company which requires the return of all condensate. Irrigation District (IID) purchases the electric power generated and provides irrigation water for cooling tower make-up to the plant for the first-five years of operation, commencing mid-1980. Because of the unavailability of irrigation water from IID in the future, SCE is investigating the application and installation of air cooled heat exchangers in conjunction with the existing wet (evaporative) cooling tower with make-up based on use of 180 gpm (nominal) of the geothermal condensate which may be made available by the steam supplier.

  11. Liquid metal cooled nuclear reactor plant system

    DOEpatents

    Hunsbedt, Anstein; Boardman, Charles E.

    1993-01-01

    A liquid metal cooled nuclear reactor having a passive cooling system for removing residual heat resulting for fuel decay during reactor shutdown, or heat produced during a mishap. The reactor system is enhanced with sealing means for excluding external air from contact with the liquid metal coolant leaking from the reactor vessel during an accident. The invention also includes a silo structure which resists attack by leaking liquid metal coolant, and an added unique cooling means.

  12. Next generation interatomic potentials for condensed systems

    NASA Astrophysics Data System (ADS)

    Handley, Christopher Michael; Behler, Jörg

    2014-07-01

    The computer simulation of condensed systems is a challenging task. While electronic structure methods like density-functional theory (DFT) usually provide a good compromise between accuracy and efficiency, they are computationally very demanding and thus applicable only to systems containing up to a few hundred atoms. Unfortunately, many interesting problems require simulations to be performed on much larger systems involving thousands of atoms or more. Consequently, more efficient methods are urgently needed, and a lot of effort has been spent on the development of a large variety of potentials enabling simulations with significantly extended time and length scales. Most commonly, these potentials are based on physically motivated functional forms and thus perform very well for the applications they have been designed for. On the other hand, they are often highly system-specific and thus cannot easily be transferred from one system to another. Moreover, their numerical accuracy is restricted by the intrinsic limitations of the imposed functional forms. In recent years, several novel types of potentials have emerged, which are not based on physical considerations. Instead, they aim to reproduce a set of reference electronic structure data as accurately as possible by using very general and flexible functional forms. In this review we will survey a number of these methods. While they differ in the choice of the employed mathematical functions, they all have in common that they provide high-quality potential-energy surfaces, while the efficiency is comparable to conventional empirical potentials. It has been demonstrated that in many cases these potentials now offer a very interesting new approach to study complex systems with hitherto unreached accuracy.

  13. Advances in Solar Heating and Cooling Systems

    ERIC Educational Resources Information Center

    Ward, Dan S.

    1976-01-01

    Reports on technological advancements in the fields of solar collectors, thermal storage systems, and solar heating and cooling systems. Diagrams aid in the understanding of the thermodynamics of the systems. (CP)

  14. Radiant vessel auxiliary cooling system

    SciTech Connect

    Germer, J.H.

    1987-07-07

    This patent describes an improved radiant vessel passive cooling system for liquid-metal poor-type modular nuclear reactors having a reactor vessel and a surrounding containment vessel spaced apart from the reactor vessel to form a first interstitial region containing an inert gas, the improvement comprising: a shell spaced apart from and surrounding the containment vessel to form a second interstitial region comprising a circulatory air passage. The circulatory air passage has an air inlet at a first position and an air outlet at a second position which is vertically higher than the first position. The second interstitial region lies between the shell and the containment vessel; and surface area extension means in the shell is longitudinally disposed from the shell into the second interstitial region towards the containment vessel to receive thermal radiation from the containment vessel. The surface area extension means is spaced apart from the external surface of the containment vessel where heat radiated form the containment vessel is received at the surface extension means for convection, conduction and radiation to air in the circulatory passage.

  15. Passive-solar directional-radiating cooling system

    DOEpatents

    Hull, J.R.; Schertz, W.W.

    1985-06-27

    A radiative cooling system for use with an ice-making system having a radiating surface aimed at the sky for radiating energy at one or more wavelength bands for which the atmosphere is transparent and a cover thermally isolated from the radiating surface and transparent at least to the selected wavelength or wavelengths, the thermal isolation reducing the formation of condensation on the radiating surface and/or cover and permitting the radiation to continue when the radiating surface is below the dewpoint of the atmosphere, and a housing supporting the radiating surface, cover and heat transfer means to an ice storage reservoir.

  16. Passive-solar directional-radiating cooling system

    DOEpatents

    Hull, John R.; Schertz, William W.

    1986-01-01

    A radiative cooling system for use with an ice-making system having a radiating surface aimed at the sky for radiating energy at one or more wavelength bands for which the atmosphere is transparent and a cover thermally isolated from the radiating surface and transparent at least to the selected wavelength or wavelengths, the thermal isolation reducing the formation of condensation on the radiating surface and/or cover and permitting the radiation to continue when the radiating surface is below the dewpoint of the atmosphere, and a housing supporting the radiating surface, cover and heat transfer means to an ice storage reservoir.

  17. The Solar lake/condensation tower system (SL/CT System)

    SciTech Connect

    deLangen, L.H.

    1983-08-01

    The system is basically an ammonia cycle between the hot water of a lake, covered with floating heat collectors and the cold air at great height of the atmosphere, only attainable by a high tower. Below, ammonia is evaporated by the water of the lake; at high level, air-cooled condensers take care of the condensation of the ammonia vapour. The system offers a possibility to be combined with a multi-stage sea-water distillation plant, enabling irrigation of deserts and steppes. In the paper attention is given to the design of the tower. Results of calculations are given about attainable energy production, quantities of building materials needed to build the tower and installations, the surface of the lake, the quantities of produced water and the surface of irrigated land.

  18. Superconducting magnet system for muon beam cooling

    SciTech Connect

    Andreev, N.; Johnson, R.P.; Kashikhin, V.S.; Kashikhin, V.V.; Novitski, I.; Yonehara, K.; Zlobin, A.; /Fermilab

    2006-08-01

    A helical cooling channel has been proposed to quickly reduce the six-dimensional phase space of muon beams for muon colliders, neutrino factories, and intense muon sources. A novel superconducting magnet system for a muon beam cooling experiment is being designed at Fermilab. The inner volume of the cooling channel is filled with liquid helium where passing muon beam can be decelerated and cooled in a process of ionization energy loss. The magnet parameters are optimized to match the momentum of the beam as it slows down. The results of 3D magnetic analysis for two designs of magnet system, mechanical and quench protection considerations are discussed.

  19. Feasibility of cool storage systems in refrigeration

    NASA Astrophysics Data System (ADS)

    Elmahgary, Yehia; Kekkonen, Veikko; Laitinen, Ari; Pihala, Hannu

    1989-05-01

    In the present report, the economic viability and technical feasibility of selected cool storage systems are considered. Cool storage has clear potential for several applications: in connection with air-conditioning systems, domestic refrigerating and freezing systems; commercially e.g., in the dairy and vegetable industries; and in deep freezing, as in the meat industry. Air-conditioning has limited significance in Finland. For this reason it was not investigated in this study. In domestic refrigeration and freezing two systems were investigated; a controlled cooling/heating system and a simple built-in system in individual refrigerators and freezers. The central cooling/heating system in houses was found to be economically unattractive. It also has several technical drawbacks. The simple built-in system appeared to be promising. The amount of savings is rationally a function of the difference between day and night tariffs and the costs of installing an automatic switch and storage media. In the vegetable and dairy industries cool storage also has considerable potential. Several systems were investigated in this respect and compared to the conventional system. The cool storage system using Cristopia balls, one of the most common commercial systems available in Europe, was not economical at a tariff difference of 10 p/k Wh or more. Cool storage for freezing in meat plants was also investigated.

  20. Solar Assisted Adsorptive Desiccant Cooling System

    NASA Astrophysics Data System (ADS)

    Ohkura, Masashi; Kodama, Akio

    Desiccant cooling processes can supply dry air by using lower temperature heat energy such as waste heat or solar heat. Especially, solar heat is useful heat source for the desiccant cooling since solar heat in summer tends to be surplus. This paper discusses the hourly cooling performance of the solar assisted desiccant cooling system, which consists of a desiccant wheel, a thermal wheel, two evaporative coolers, a cooling coil and flat plate solar water heater, assuming that the cooling system is applied to an office room of 250m3 in volume. The estimation indicated that the surface area needed to satisfy the dehumidifying performance in a sunny day was at least 30m2. Furthermore, surface area of 40m2 or larger provided a surplus dehumidifying performance causing a sensible cooling effect in evaporative cooler. Surface area of 30 m2 did not satisfy the dehumidifying performance required for high humidity condition, over 18.0g/kg(DA). The cooling demand of the cooling coil increased in such humidity condition due to the decrease in the sensible cooling effect of evaporative cooler. Auxiliary heater was required in a cloudy day since the temperature of water supplied from solar water heater of 40m2 did not reach sufficient level.

  1. Hot gas path component cooling system

    DOEpatents

    Lacy, Benjamin Paul; Bunker, Ronald Scott; Itzel, Gary Michael

    2014-02-18

    A cooling system for a hot gas path component is disclosed. The cooling system may include a component layer and a cover layer. The component layer may include a first inner surface and a second outer surface. The second outer surface may define a plurality of channels. The component layer may further define a plurality of passages extending generally between the first inner surface and the second outer surface. Each of the plurality of channels may be fluidly connected to at least one of the plurality of passages. The cover layer may be situated adjacent the second outer surface of the component layer. The plurality of passages may be configured to flow a cooling medium to the plurality of channels and provide impingement cooling to the cover layer. The plurality of channels may be configured to flow cooling medium therethrough, cooling the cover layer.

  2. Passive decay heat removal system for water-cooled nuclear reactors

    DOEpatents

    Forsberg, Charles W.

    1991-01-01

    A passive decay-heat removal system for a water-cooled nuclear reactor employs a closed heat transfer loop having heat-exchanging coils inside an open-topped, insulated box located inside the reactor vessel, below its normal water level, in communication with a condenser located outside of containment and exposed to the atmosphere. The heat transfer loop is located such that the evaporator is in a position where, when the water level drops in the reactor, it will become exposed to steam. Vapor produced in the evaporator passes upward to the condenser above the normal water level. In operation, condensation in the condenser removes heat from the system, and the condensed liquid is returned to the evaporator. The system is disposed such that during normal reactor operations where the water level is at its usual position, very little heat will be removed from the system, but during emergency, low water level conditions, substantial amounts of decay heat will be removed.

  3. Methods to reduce bacterial contamination of recycling cooling systems of a CHPP

    NASA Astrophysics Data System (ADS)

    Chichirova, N. D.; Chichirov, A. A.; Vlasov, S. M.; Vlasova, A. Yu.

    2015-07-01

    Bacterial contamination of circulating and make-up water of the nonconjugated recycling cooling system with evaporative cooling towers of thermal power plants is studied. The nonconjugated recycling cooling system of Naberezhnochelninskaya CHP Plant was selected as the object of study. It was found that circulating water of recycling cooling is highly contaminated with aerobic heterotrophic bacteria. At the same time, make-up water for the cooling system from the Kama River is moderately polluted with anaerobic bacteria. Measurements of biological contamination in different parts of the recycling cooling system showed that populations of colonies of microorganisms abruptly decreases in turbine condensers, which is probably indicative of their death and deposition on the heat transfer surface of the condenser. Calculation using a special program showed that biological contamination of the recycling cooling system poses the greatest risks for clogging of the equipment (seven points on a nine-point scale), its corrosion (two points), and damage to the health of personnel (two points). Rapid development of aerobic bacteria apparently occurs under elevated temperature and intense aeration of water in the cooling tower. It is suggested to periodically monitor the recycling cooling system for biological pollution and to set a timetable for bactericidal treatment of circulating water depending on the level of its bacterial contamination.

  4. Desiccant cooling system performance: A simple approach

    NASA Astrophysics Data System (ADS)

    Epstein, M.; Grolmes, M. A.

    1982-10-01

    The wave nature of heat and mass transfer in fixed desiccant bed adsorption is explained. A simple algebraic model of wave motion under single low desiccant bed operation is developed and applied to the prediction of the performance potential of the overall desiccant cooling system. The model is used to explain the increase in cooling system performance that is realized through the use of mixed inert desiccant material adsorption beds. The response of cooling system performance to changes in external process conditions is examined and conclusions are drawn relative to optimization of system characteristics.

  5. The impacts of cooling construction on the ability distract the heat of condensation part of the heat pipe

    NASA Astrophysics Data System (ADS)

    Čaja, A.; Nemec, P.; Malcho, M.; Gavlas, S.

    2013-04-01

    Heat pipes as cooling devices have a high potential. Their power to affect a variety of factors - the vapour pressure, the amount of media work etc. Itis therefore necessary to verify the calculated parameters also practically. To determine the performance of transmitted heat pipe is the best calorimetric method. When it is out of the flow and the temperature difference the cooling part of the heat pipe determines its transmitted power. The contribution is focused on comparison of two types of coolers. The first type is looped capillary cooler for the condenser section. The small diameter capillary is secured high coolant turbulence and hence heat dissipation. The second type is non-contact cooling, where cooling fluid washes direct heat pipe wall.

  6. Utilization of municipal wastewater for cooling in thermoelectric power plants: Evaluation of the combined cost of makeup water treatment and increased condenser fouling

    SciTech Connect

    Walker, Michael E.; Theregowda, Ranjani B.; Safari, Iman; Abbasian, Javad; Arastoopour, Hamid; Dzombak, David A.; Hsieh, Ming-Kai; Miller, David C.

    2013-10-01

    A methodology is presented to calculate the total combined cost (TCC) of water sourcing, water treatment and condenser fouling in the recirculating cooling systems of thermoelectric power plants. The methodology is employed to evaluate the economic viability of using treated municipal wastewater (MWW) to replace the use of freshwater as makeup water to power plant cooling systems. Cost analyses are presented for a reference power plant and five different tertiary treatment scenarios to reduce the scaling tendencies of MWW. Results indicate that a 550 MW sub-critical coal fired power plant with a makeup water requirement of 29.3 ML/day has a TCC of $3.0 - 3.2 million/yr associated with the use of treated MWW for cooling. (All costs USD 2009). This translates to a freshwater conservation cost of $0.29/kL, which is considerably lower than that of dry air cooling technology, $1.5/kL, as well as the 2020 conservation cost target set by the U.S. Department of Energy, $0.74/kL. Results also show that if the available price of freshwater exceeds that of secondary-treated MWW by more than $0.13-0.14/kL, it can be economically advantageous to purchase secondary MWW and treat it for utilization in the recirculating cooling system of a thermoelectric power plant.

  7. Effects of Tube Diameter and Tubeside Fin Geometry on the Heat Transfer Performance of Air-Cooled Condensers

    NASA Astrophysics Data System (ADS)

    Wang, H. S.; Honda, Hiroshi

    A theoretical study has been made on the effects of tube diameter and tubeside fin geometry on the heat transfer performance of air-cooled condensers. Extensive numerical calculations of overall heat transfer from refrigerant R410A flowing inside a horizontal microfin tube to ambient air were conducted for a typical operating condition of the air-cooled condenser. The tubeside heat transfer coefficient was calculated by applying a modified stratified flow model developed by Wang et al.8). The numerical results show that the effects of tube diameter, fin height, fin number and helix angle of groove are significant, whereas those of the width of flat portion at the fin tip, the radius of round corner at the fin tip and the fin half tip angle are small.

  8. Cooling system for a nuclear reactor

    DOEpatents

    Amtmann, Hans H.

    1982-01-01

    A cooling system for a gas-cooled nuclear reactor is disclosed which includes at least one primary cooling loop adapted to pass coolant gas from the reactor core and an associated steam generator through a duct system having a main circulator therein, and at least one auxiliary cooling loop having communication with the reactor core and adapted to selectively pass coolant gas through an auxiliary heat exchanger and circulator. The main and auxiliary circulators are installed in a common vertical cavity in the reactor vessel, and a common return duct communicates with the reactor core and intersects the common cavity at a junction at which is located a flow diverter valve operative to effect coolant flow through either the primary or auxiliary cooling loops.

  9. Gas hydrate cool storage system

    DOEpatents

    Ternes, Mark P.; Kedl, Robert J.

    1985-01-01

    This invention is a process for formation of a gas hydrate to be used as a cool storage medium using a refrigerant in water. Mixing of the immiscible refrigerant and water is effected by addition of a surfactant and agitation. The difficult problem of subcooling during the process is overcome by using the surfactant and agitation and performance of the process significantly improves and approaches ideal.

  10. Elastocaloric cooling materials and systems

    NASA Astrophysics Data System (ADS)

    Takeuchi, Ichiro

    2015-03-01

    We are actively pursuing applications of thermoelastic (elastocaloric) cooling using shape memory alloys. Latent heat associated with martensitic transformation of shape memory alloys can be used to run cooling cycles with stress-inducing mechanical drives. The coefficient of performance of thermoelastic cooling materials can be as high as 11 with the directly measured DT of around 17 °C. Depending on the stress application mode, the number of cycles to fatigue can be as large as of the order of 105. Efforts to design and develop thermoelastic alloys with long fatigue life will be discussed. The current project at the University of Maryland is focused on development of building air-conditioners, and at Maryland Energy and Sensor Technologies, smaller scale commercial applications are being pursued. This work is carried out in collaboration with Jun Cui, Yiming Wu, Suxin Qian, Yunho Hwang, Jan Muehlbauer, and Reinhard Radermacher, and it is funded by the ARPA-E BEETIT program and the State of Maryland.

  11. Spark gap switch system with condensable dielectric gas

    DOEpatents

    Thayer, III, William J.

    1991-01-01

    A spark gap switch system is disclosed which is capable of operating at a high pulse rate comprising an insulated switch housing having a purging gas entrance port and a gas exit port, a pair of spaced apart electrodes each having one end thereof within the housing and defining a spark gap therebetween, an easily condensable and preferably low molecular weight insulating gas flowing through the switch housing from the housing, a heat exchanger/condenser for condensing the insulating gas after it exits from the housing, a pump for recirculating the condensed insulating gas as a liquid back to the housing, and a heater exchanger/evaporator to vaporize at least a portion of the condensed insulating gas back into a vapor prior to flowing the insulating gas back into the housing.

  12. Biomedical Application of Aerospace Personal Cooling Systems

    NASA Technical Reports Server (NTRS)

    Ku, Yu-Tsuan E.; Lee, Hank C.; Montgomery, Leslie D.; Webbon, Bruce W.; Kliss, Mark (Technical Monitor)

    1997-01-01

    Personal thermoregulatory systems which are used by astronauts to alleviate thermal stress during extravehicular activity have been applied to the therapeutic management of multiple sclerosis. However, little information is available regarding the physiologic and circulatory changes produced by routine operation of these systems. The objectives of this study were to compare the effectiveness of two passive and two active cooling vests and to measure the body temperature and circulatory changes produced by each cooling vest configuration. The MicroClimate Systems and the Life Enhancement Tech(LET) lightweight liquid cooling vests, the Steele Vest and LET's Zipper Front Garment were used to cool the chest region of 10 male and female subjects (25 to 55 yr.) in this study. Calf, forearm and finger blood flows were measured using a tetrapolar impedance rheograph. The subjects, seated in an upright position at normal room temperature (approx.22C), were tested for 60 min. with the cooling system operated at its maximum cooling capacity. Blood flows were recorded continuously using a computer data acquisition system with a sampling frequency of 250 Hz. Oral, right and left ear temperatures and cooling system parameters were logged manually every 5 min. Arm, leg, chest and rectal temperatures; heart rate; respiration; and an activity index were recorded continuously on a U.F.I., Inc. Biolog ambulatory monitor. In general, the male and female subjects' oral and ear temperature responses to cooling were similar for all vest configurations tested. Oral temperatures during the recovery period were significantly (P<0.05) lower than during the control period, approx. 0.2 - 0.5C, for both men and women wearing any of the four different garments. The corresponding ear temperatures were significantly (P<0.05) decreased approx.0.2 - 0.4C by the end of the recovery period. Compared to the control period, no significant differences were found in rectal temperatures during cooling and

  13. Cooling system for cooling the bits of a cutting machine

    SciTech Connect

    Wrulich, H.; Gekle, S.; Schetina, O.; Zitz, A.

    1984-06-26

    The invention refers to a system for cooling the bits of a cutting machine and comprising a nozzle for the cooling water to be ejected under pressure, said nozzle being arranged at the area of the bit, the water supply to said nozzle being closable by means of a shutoff valve and the bit being supported on the bit holder for limited axial shifting movement under the action of the cutting pressure against the force of a spring and against the hydraulic pressure of the cooling water and the shutoff valve being coupled with the bit by means of a coupling member such that the shutoff valve is opened on shifting movement of the bit in direction of the cutting pressure. In this system the arrangement is such that the bit (6) has in a manner known per se the shape of a cap and is enclosing a bit shaft (3) adapted to be inserted into the bit holder (1), in that the cap-shaped bit (6) is supported on the shaft (3) for shifting movement in axial direction and in that the shutoff valve (11) and the coupling member (10) are arranged within the bit shaft (3). The coupling member is formed of a push rod (10) acting on the closure member (11) of the valve, said push rod being guided within a central bore (9) of the bit shaft and the closure member (11) closing the valve in opposite direction to the action of the cutting pressure and being moved in open position by the push rod (10) in direction of the acting cutting pressure.

  14. Effectiveness-weighted control of cooling system components

    SciTech Connect

    Campbell, Levi A.; Chu, Richard C.; David, Milnes P.; Ellsworth Jr., Michael J.; Iyengar, Madhusudan K.; Schmidt, Roger R.; Simmons, Robert E.

    2015-12-22

    Energy efficient control of cooling system cooling of an electronic system is provided based, in part, on weighted cooling effectiveness of the components. The control includes automatically determining speed control settings for multiple adjustable cooling components of the cooling system. The automatically determining is based, at least in part, on weighted cooling effectiveness of the components of the cooling system, and the determining operates to limit power consumption of at least the cooling system, while ensuring that a target temperature associated with at least one of the cooling system or the electronic system is within a desired range by provisioning, based on the weighted cooling effectiveness, a desired target temperature change among the multiple adjustable cooling components of the cooling system. The provisioning includes provisioning applied power to the multiple adjustable cooling components via, at least in part, the determined control settings.

  15. Effectiveness-weighted control method for a cooling system

    DOEpatents

    Campbell, Levi A.; Chu, Richard C.; David, Milnes P.; Ellsworth Jr., Michael J.; Iyengar, Madhusudan K.; Schmidt, Roger R.; Simons, Robert E.

    2015-12-15

    Energy efficient control of cooling system cooling of an electronic system is provided based, in part, on weighted cooling effectiveness of the components. The control includes automatically determining speed control settings for multiple adjustable cooling components of the cooling system. The automatically determining is based, at least in part, on weighted cooling effectiveness of the components of the cooling system, and the determining operates to limit power consumption of at least the cooling system, while ensuring that a target temperature associated with at least one of the cooling system or the electronic system is within a desired range by provisioning, based on the weighted cooling effectiveness, a desired target temperature change among the multiple adjustable cooling components of the cooling system. The provisioning includes provisioning applied power to the multiple adjustable cooling components via, at least in part, the determined control settings.

  16. The absorption chiller in large scale solar pond cooling design with condenser heat rejection in the upper convecting zone

    SciTech Connect

    Tsilingiris, P.T. )

    1992-07-01

    The possibility of using solar ponds as low-cost solar collectors combined with commercial absorption chillers in large scale solar cooling design is investigated. The analysis is based on the combination of a steady-state solar pond mathematical model with the operational characteristics of a commercial absorption chiller, assuming condenser heat rejection in the upper convecting zone (U.C.Z.). The numerical solution of the nonlinear equations involved leads to results which relate the chiller capacity with pond design and environmental parameters, which are also employed for the investigation of the optimum pond size for a minimum capital cost. The derived cost per cooling kW for a 350 kW chiller ranges from about 300 to 500 $/kW cooling. This is almost an order of magnitude lower than using a solar collector field of evacuated tube type.

  17. Passive cooling system for top entry liquid metal cooled nuclear reactors

    DOEpatents

    Boardman, Charles E.; Hunsbedt, Anstein; Hui, Marvin M.

    1992-01-01

    A liquid metal cooled nuclear fission reactor plant having a top entry loop joined satellite assembly with a passive auxiliary safety cooling system for removing residual heat resulting from fuel decay during shutdown, or heat produced during a mishap. This satellite type reactor plant is enhanced by a backup or secondary passive safety cooling system which augments the primary passive auxiliary cooling system when in operation, and replaces the primary cooling system when rendered inoperative.

  18. Cooling system with automated seasonal freeze protection

    DOEpatents

    Campbell, Levi A.; Chu, Richard C.; David, Milnes P.; Ellsworth, Jr., Michael J.; Iyengar, Madhusudan K.; Simons, Robert E.; Singh, Prabjit; Zhang, Jing

    2016-05-24

    An automated multi-fluid cooling system and method are provided for cooling an electronic component(s). The cooling system includes a coolant loop, a coolant tank, multiple valves, and a controller. The coolant loop is at least partially exposed to outdoor ambient air temperature(s) during normal operation, and the coolant tank includes first and second reservoirs containing first and second fluids, respectively. The first fluid freezes at a lower temperature than the second, the second fluid has superior cooling properties compared with the first, and the two fluids are soluble. The multiple valves are controllable to selectively couple the first or second fluid into the coolant in the coolant loop, wherein the coolant includes at least the second fluid. The controller automatically controls the valves to vary first fluid concentration level in the coolant loop based on historical, current, or anticipated outdoor air ambient temperature(s) for a time of year.

  19. Simulation of the passive condensation cooling tank of the PASCAL test facility using the component thermal-hydraulic analysis code CUPID

    SciTech Connect

    Cho, H. K.; Lee, S. J.; Kang, K. H.; Yoon, H. Y.

    2012-07-01

    For the analysis of transient two-phase flows in nuclear reactor components, a three-dimensional thermal hydraulics code, named CUPID, has been being developed. In the present study, the CUPID code was applied for the simulation of the PASCAL (PAFS Condensing Heat Removal Assessment Loop) test facility constructed with an aim of validating the cooling and operational performance of the PAFS (Passive Auxiliary Feedwater System). The PAFS is one of the advanced safety features adopted in the APR+ (Advanced Power Reactor +), which is intended to completely replace the conventional active auxiliary feedwater system. This paper presents the preliminary simulation results of the PASCAL facility performed with the CUPID code in order to verify its applicability to the thermal-hydraulic phenomena inside the system. A standalone calculation for the passive condensation cooling tank was performed by imposing a heat source boundary condition and the transient thermal-hydraulic behaviors inside the system, such as the water level, temperature and velocity, were qualitatively investigated. The simulation results verified that the natural circulation and boiling phenomena in the water pool can be well reproduced by the CUPID code. (authors)

  20. New desalination concept: the solar evaporator and condenser system (SEACS)

    SciTech Connect

    ElDifrawi, A.; Yudow, B.; Grotheer, R.H.

    1981-01-01

    A new concept for a solar-powered, modular desalination plant has been developed. Plants will utilize a Solar Evaporator and Condenser System which provides a simple, reliable, and low-cost method for desalination. The system is an augmented solar still. Air drawn at low velocity over glazed solar ponds picks up moisture and transports it to a condenser where it picks up the latent heat of condensation. The warm seawater then flows by gravity through the ponds and is pumped over an evaporator pad at the air stream inlet. Most of the latent heat of condensation recovered at the condenser will provide additional moisture to the air stream. The cold brine will flow by gravity back to the sea. Product water from the condenser is stored for subsequent use by the community. The level of technology is low. Major components are low speed pumps and fans, heat exchangers, battery storage systems, and photovoltaic power panels. Plant capacity is determined by the number of modules in the plant. Total electric power requirements are anticipated to be as low as 1.2 to 1.5 kWhr/m/sup 3/ of product water. Cost of water production over the 20-year plant life is estimated to be $2.40/m/sup 3/. System is attractive in its simplicity, both from a construction and operation standpoint.

  1. Cooling system for continuous metal casting machines

    DOEpatents

    Draper, R.; Sumpman, W.C.; Baker, R.J.; Williams, R.S.

    1988-06-07

    A continuous metal caster cooling system is provided in which water is supplied in jets from a large number of small nozzles against the inner surface of rim at a temperature and with sufficient pressure that the velocity of the jets is sufficiently high that the mode of heat transfer is substantially by forced convection, the liquid being returned from the cooling chambers through return pipes distributed interstitially among the nozzles. 9 figs.

  2. Cooling system for continuous metal casting machines

    DOEpatents

    Draper, Robert; Sumpman, Wayne C.; Baker, Robert J.; Williams, Robert S.

    1988-01-01

    A continuous metal caster cooling system is provided in which water is supplied in jets from a large number of small nozzles 19 against the inner surface of rim 13 at a temperature and with sufficient pressure that the velocity of the jets is sufficiently high that the mode of heat transfer is substantially by forced convection, the liquid being returned from the cooling chambers 30 through return pipes 25 distributed interstitially among the nozzles.

  3. Rust Inhibitor And Fungicide For Cooling Systems

    NASA Technical Reports Server (NTRS)

    Adams, James F.; Greer, D. Clay

    1988-01-01

    Mixture of benzotriazole, benzoic acid, and fungicide prevents growth of rust and fungus. Water-based cooling mixture made from readily available materials prevents formation of metallic oxides and growth of fungi in metallic pipes. Coolant remains clear and does not develop thick sludge tending to collect in low points in cooling systems with many commercial rust inhibitors. Coolant compatible with iron, copper, aluminum, and stainless steel. Cannot be used with cadmium or cadmium-plated pipes.

  4. Condensation model for the ESBWR passive condensers

    SciTech Connect

    Revankar, S. T.; Zhou, W.; Wolf, B.; Oh, S.

    2012-07-01

    In the General Electric's Economic simplified boiling water reactor (GE-ESBWR) the passive containment cooling system (PCCS) plays a major role in containment pressure control in case of an loss of coolant accident. The PCCS condenser must be able to remove sufficient energy from the reactor containment to prevent containment from exceeding its design pressure following a design basis accident. There are three PCCS condensation modes depending on the containment pressurization due to coolant discharge; complete condensation, cyclic venting and flow through mode. The present work reviews the models and presents model predictive capability along with comparison with existing data from separate effects test. The condensation models in thermal hydraulics code RELAP5 are also assessed to examine its application to various flow modes of condensation. The default model in the code predicts complete condensation well, and basically is Nusselt solution. The UCB model predicts through flow well. None of condensation model in RELAP5 predict complete condensation, cyclic venting, and through flow condensation consistently. New condensation correlations are given that accurately predict all three modes of PCCS condensation. (authors)

  5. Flexible beam shaping system using fly's eye condenser.

    PubMed

    Lindlein, Norbert; Bich, Andreas; Eisner, Martin; Harder, Irina; Lano, Maik; Voelkel, Reinhard; Weible, Ken; Zimmermann, Maik

    2010-04-20

    Normally, fly's eye condensers are used to homogenize light. However, in the case of fully coherent light, a fly's eye condenser, in connection with some simple optical elements, such as a diffractive axicon, a grating, and a telescope, can be used as a quite flexible beam shaping system, forming arrays of rings, parts of rings, or other structures with varying diameters. We present the principle, some simulation results, and some first experimental results. PMID:20411020

  6. Dual-purpose chamber-cooling system

    NASA Technical Reports Server (NTRS)

    Fraze, R. E.

    1968-01-01

    Inexpensive, portable system was designed for cooling small environmental test chambers with a temperature-controlled gas stream evaporated from a cryogenic liquid. The system reduces the temperature of a chamber to any desired point in a fraction of the time required by previous systems.

  7. Residential solar-heating/cooling system

    NASA Technical Reports Server (NTRS)

    1980-01-01

    Report documents progress of residential solar-heating and cooling system development program at 5-month mark of anticipated 17-month program. System design has been completed, and development and component testing has been initiated. Report includes diagrams, operation overview, optimization studies of subcomponents, and marketing plans for system.

  8. Prototype solar heating and cooling systems

    NASA Technical Reports Server (NTRS)

    1978-01-01

    A collection of monthly status reports on the development of eight prototype solar heating and cooling systems is presented. The effort calls for the development, manufacture, test, system installation, maintenance, problem resolution, and performance evaluation. The systems are 3, 25, and 75 ton size units.

  9. Prototype solar heating and cooling systems

    NASA Technical Reports Server (NTRS)

    1978-01-01

    A collection of monthly status reports are given on the development of eight prototype solar heating and cooling systems. This effort calls for the development, manufacturing, test, system installation, maintenance, problem resolution, and performance evaluation. The systems are 3-, 25-, and 75-ton size units.

  10. Optimum dry-cooling sub-systems for a solar air conditioner

    NASA Technical Reports Server (NTRS)

    Chen, J. L. S.; Namkoong, D.

    1978-01-01

    Dry-cooling sub-systems for residential solar powered Rankine compression air conditioners were economically optimized and compared with the cost of a wet cooling tower. Results in terms of yearly incremental busbar cost due to the use of dry-cooling were presented for Philadelphia and Miami. With input data corresponding to local weather, energy rate and capital costs, condenser surface designs and performance, the computerized optimization program yields design specifications of the sub-system which has the lowest annual incremental cost.

  11. Controlled cooling of an electronic system for reduced energy consumption

    DOEpatents

    David, Milnes P.; Iyengar, Madhusudan K.; Schmidt, Roger R.

    2016-08-09

    Energy efficient control of a cooling system cooling an electronic system is provided. The control includes automatically determining at least one adjusted control setting for at least one adjustable cooling component of a cooling system cooling the electronic system. The automatically determining is based, at least in part, on power being consumed by the cooling system and temperature of a heat sink to which heat extracted by the cooling system is rejected. The automatically determining operates to reduce power consumption of the cooling system and/or the electronic system while ensuring that at least one targeted temperature associated with the cooling system or the electronic system is within a desired range. The automatically determining may be based, at least in part, on one or more experimentally obtained models relating the targeted temperature and power consumption of the one or more adjustable cooling components of the cooling system.

  12. Analysis of cooling systems for hypersonic aircraft

    NASA Technical Reports Server (NTRS)

    Petley, Dennis H.; Jones, Stuart C.; Dziedzic, William M.

    1991-01-01

    A computer program has been written to analyze cooling systems of hypersonic aircraft. This computer program called NASP/SINDA is written into the SINDA'85 command structure and uses the SINDA'85 finite difference subroutines. Both internal fluid flow and heat transfer must be analyzed, because increased heating causes a decrease in the flow of the coolant. Also local hot spots will cause a redistribution of the coolant in the system. Both steady state and transient analyses have been performed. Details of empirical correlations are presented. Results for two cooling system applications are given.

  13. Thermal design of lithium bromide-water solution vapor absorption cooling system for indirect evaporative cooling for IT pod

    NASA Astrophysics Data System (ADS)

    Sawant, Digvijay Ramkrishna

    Nowadays with increase use of internet, mobile there is increase in heat which ultimately increases the efficient cooling system of server room or IT POD. Use of traditional ways of cooling system has ultimately increased CO2 emission and depletion of CFC's are serious environmental issues which led scientific people to improve cooling techniques and eliminate use of CFC's. To reduce dependency on fossil fuels and 4environmental friendly system needed to be design. For being utilizing low grade energy source such as solar collector and reducing dependency on fossil fuel vapour absorption cooling system has shown a great driving force in today's refrigeration systems. This LiBr-water aabsorption cooling consists of five heat exchanger namely: Evaporator, Absorber, Solution Heat Exchanger, Generator, Condenser. The thermal design was done for a load of 23 kW and the procedure was described in the thesis. There are 120 servers in the IT POD emitting 196 W of heat each on full load and some of the heat was generated by the computer placed inside the IT POD. A detailed procedure has been discussed. A excel spreadsheet was to prepared with varying tube sizes to see the effect on flows and ultimately overall heat transfer coefficient.

  14. Study of Fluid Cooling Loop System in Chinese Manned Spacecraft

    NASA Astrophysics Data System (ADS)

    Jiang, Jun; Xu, Jiwan; Fan, Hanlin; Huang, Jiarong

    2002-01-01

    change. To solve the questions, a fluid cooling loop system must be applied to Chinese manned spacecraft besides other conventional thermal control methods, such as thermal control coatings, multiplayer insulation blankets, heat pipes, electro-heating adjustment temperature devices, and so on. The paper will introduce the thermal design of inner and outer fluid loop including their constitution and fundamental, etc. The capability of heat transportation and the accuracy of control temperature for the fluid loop will be evaluated and analyzed. To insure the air temperature of sealed cabins within 21+/-4, the inlet liquid temperature of condensing heat exchanger needs to be controlled within 9+/-2. To insure this, the inlet liquid temperature of middle heat exchanger needs to be controlled within 8+/-1.8. The inlet temperature point is controlled by a subsidiary loop adjusting: when the computer receives feedbacks of the deviation and the variety rate of deviation from the controlled temperature point. It drives the temperature control valve to adjust the flow flux distribution between the main loop through radiator and the subsidiary loop which isn't through radiator to control the temperature of the mixed fluid within 8+/-1.8. The paper will also introduce thermal designs of key parts in the cooling loop, such as space radiators, heat exchangers and cooling plates. Thermal simulated tests on the ground and flight tests have been performed to verify correctness of thermal designs. rational and the loop system works order. It realizes the circulation of absorbing heat dissipation to the loop and transferring it to radiator then radiating it to space. (2) loop control system controls inlet temperature of middle heat exchanger within 8+/-1.8 under various thermal cases. Thermal design of the middle heat exchanger insures inlet temperature of condensing heat within 9+/-2. Thereby, the air temperature of sealed cabins is controlled within about 21+/-4 accurately. (3) The

  15. Evaluation of three commercial microclimate cooling systems

    NASA Astrophysics Data System (ADS)

    Cadarette, Bruce S.; Decristofano, Barry S.; Speckman, Karen N.; Sawka, Michael N.

    1988-11-01

    Three commercially available microclimate cooling systems were evaluated for their ability to reduce heat stress in men exercising in a hot environment while wearing high insulative, low permeability clothing. The cooling systems were: (1) ILC Dover Model 19 Coolvest (ILC) (2) LSSI Coolhead(LSSI), and (3) Thermacor Cooling vest (THERM). Endurance Time (ET), Heart Rate (HR), rectal temperature (Tre), mean skin temperature (TSK), Sweating Rate (SR), Rated Perceived Exertion (RPE) and Thermal Sensation (TS) were measured. The subjects self-terminated on all LSSI tests because of headaches. Statistical analyses were performed on data collected at 60 minutes to have values on all subjects. There were no differences in HR, Tre, SR or TS values among the cooling vests. The subjects' TSK was lower (P less than 0.05) for the LSSI than THERM: and RPE values were higher (P less than 0.05) for LSSI than the other two vests. These data suggest an improved physiological response to exercise heat stress with all three commercial systems with the greatest benefit in performance time provided by the ILC cooling system.

  16. Experimental study on the operational and the cooling performance of the APR+ passive auxiliary feedwater system

    SciTech Connect

    Kang, K. H.; Bae, B. U.; Kim, S.; Cho, Y. J.; Park, Y. S.; Kim, B. D.

    2012-07-01

    The passive auxiliary feedwater system (PAFS) is one of the advanced safety features adopted in the APR+ which is intended to completely replace the conventional active auxiliary feedwater system. The PAFS cools down the steam generator secondary side and eventually removes the decay heat from the reactor core by introducing a natural driving force mechanism; i.e., condensing steam in nearly-horizontal U-tubes submerged inside the passive condensation cooling tank (PCCT). With an aim of validating the cooling and operational performance of the PAFS, the separate effect test, PASCAL (PAFS Condensing Heat Removal Assessment Loop), is being performed to experimentally investigate the condensation heat transfer and natural convection phenomena in the PAFS. A single nearly-horizontal U-tube whose dimension is same as the prototypic U-tube of the APR+ PAFS is simulated in the PASCAL test. By performing the PASCAL test, the major thermal-hydraulic parameters such as local/overall heat transfer coefficients, fluid temperature inside the tube, wall temperature of the tube, and pool temperature distribution in the PCCT were produced not only to evaluate the current condensation heat transfer model but also to present database for the safety analysis related with the PAFS. (authors)

  17. Accelerated Superposition State Molecular Dynamics for Condensed Phase Systems.

    PubMed

    Ceotto, Michele; Ayton, Gary S; Voth, Gregory A

    2008-04-01

    An extension of superposition state molecular dynamics (SSMD) [Venkatnathan and Voth J. Chem. Theory Comput. 2005, 1, 36] is presented with the goal to accelerate timescales and enable the study of "long-time" phenomena for condensed phase systems. It does not require any a priori knowledge about final and transition state configurations, or specific topologies. The system is induced to explore new configurations by virtue of a fictitious (free-particle-like) accelerating potential. The acceleration method can be applied to all degrees of freedom in the system and can be applied to condensed phases and fluids. PMID:26620930

  18. Gemini helium closed cycle cooling system

    NASA Astrophysics Data System (ADS)

    Lazo, Manuel; Galvez, Ramon; Rogers, Rolando; Solis, Hernan; Tapia, Eduardo; Maltes, Diego; Collins, Paul; White, John; Cavedoni, Chas; Yamasaki, Chris; Sheehan, Michael P.; Walls, Brian

    2008-07-01

    The Gemini Observatory presents the Helium Closed Cycle Cooling System that provides cooling capacity at cryogenic temperatures for instruments and detectors. It is implemented by running three independent helium closed cycle cooling circuits with several banks of compressors in parallel to continuously supply high purity helium gas to cryocoolers located about 100-120 meters apart. This poster describes how the system has been implemented, the required helium pressures and gas flow to reach cryogenic temperature, the performance it has achieved, the helium compressors and cryocoolers in use and the level of vibration the cryocoolers produce in the telescope environment. The poster also describes the new technology for cryocoolers that Gemini is considering in the development of new instruments.

  19. Passive cooling system for liquid metal cooled nuclear reactors with backup coolant flow path

    DOEpatents

    Hunsbedt, Anstein; Boardman, Charles E.

    1993-01-01

    A liquid metal cooled nuclear fission reactor plant having a passive auxiliary safety cooling system for removing residual heat resulting from fuel decay during reactor shutdown, or heat produced during a mishap. This reactor plant is enhanced by a backup or secondary passive safety cooling system which augments the primary passive auxiliary cooling system when in operation, and replaces the primary system when rendered inoperable.

  20. LIFE-CYCLE COST ANALYSIS FOR CONDENSATE RECEIVING SYSTEM

    SciTech Connect

    Russell E. Flye

    1995-01-18

    The purpose of this analysis is to determine the life-cycle costs of several options relevant to the Condensate Removal System serving the Compressed Air System (CAS) at the Yucca Mountain Site Characterization Project (YMP) Exploratory Studies Facility (ESF). The best option (least present value) will be selected as the preferred configuration to construct.

  1. PCM Passive Cooling System Containing Active Subsystems

    NASA Technical Reports Server (NTRS)

    Blanding, David E.; Bass, David I.

    2005-01-01

    A multistage system has been proposed for cooling a circulating fluid that is subject to intermittent intense heating. The system would be both flexible and redundant in that it could operate in a basic passive mode, either sequentially or simultaneously with operation of a first, active cooling subsystem, and either sequentially or simultaneously with a second cooling subsystem that could be active, passive, or a combination of both. This flexibility and redundancy, in combination with the passive nature of at least one of the modes of operation, would make the system more reliable, relative to a conventional cooling system. The system would include a tube-in-shell heat exchanger, within which the space between the tubes would be filled with a phase-change material (PCM). The circulating hot fluid would flow along the tubes in the heat exchanger. In the basic passive mode of operation, heat would be conducted from the hot fluid into the PCM, wherein the heat would be stored temporarily by virtue of the phase change.

  2. Numerical simulation of heat transfer performance of an air-cooled steam condenser in a thermal power plant

    NASA Astrophysics Data System (ADS)

    Gao, Xiufeng; Zhang, Chengwei; Wei, Jinjia; Yu, Bo

    2009-09-01

    Numerical simulation of the thermal-flow characteristics and heat transfer performance is made of an air-cooled steam condenser (ACSC) in a thermal power plant by considering the effects of ambient wind speed and direction, air-cooled platform height, location of the main factory building and terrain condition. A simplified physical model of the ACSC combined with the measured data as input parameters is used in the simulation. The wind speed effects on the heat transfer performance and the corresponding steam turbine back pressure for different heights of the air-cooled platform are obtained. It is found that the turbine back pressure (absolute pressure) increases with the increase of wind speed and the decrease of platform height. This is because wind can not only reduce the flowrate in the axial fans, especially at the periphery of the air-cooled platform, due to cross-flow effects, but also cause an air temperature increase at the fan inlet due to hot air recirculation, resulting in the deterioration of the heat transfer performance. The hot air recirculation is found to be the dominant factor because the main factory building is situated on the windward side of the ACSC.

  3. Atmospheric impacts of evaporative cooling systems

    SciTech Connect

    Carson, J.E.

    1980-01-01

    The observed atmospheric impacts resulting from the use of evaporative cooling systems are minor and usually environmentally acceptable. Although these impacts are also considerably smaller than those usually predicted a few years ago, regulatory agency requirements are such that these effects must be identified and quantified.

  4. Condensing Heat Exchanger Concept Developed for Space Systems

    NASA Technical Reports Server (NTRS)

    Hasan, Mohammad M.; Nayagam, Vedha

    2005-01-01

    The current system for moisture removal and humidity control for the space shuttles and the International Space Station uses a two-stage process. Water first condenses onto fins and is pulled through "slurper bars." These bars take in a two-phase mixture of air and water that is then separated by the rotary separator. A more efficient design would remove the water directly from the air without the need of an additional water separator downstream. For the Condensing Heat Exchanger for Space Systems (CHESS) project, researchers at the NASA Glenn Research Center in collaboration with NASA Johnson Space Center are designing a condensing heat exchanger that utilizes capillary forces to collect and remove water and that can operate in varying gravitational conditions including microgravity, lunar gravity, and Martian gravity.

  5. Cooled baffle system for spaceborne infrared telescopes.

    PubMed

    Bock, J J; Lange, A E; Matsuhara, H; Matsumoto, T; Onaka, T; Sato, S

    1995-05-01

    We report the design and testing of a compact system of baffles for cooled infrared telescopes. The baffle system consists of a reflecting forebaffle and a black aftbaffle and provides a high level of rejection of emission from off-axis sources. The forebaffle reflects radiation incident at angles greater than 40° off axis out of the telescope, thereby reducing the aperture heat load. The black aftbaffle absorbs radiation scattered or diffracted by the forebaffle, as well as radiation from sources within 40° off axis. We describe ground-based measurements at λ = 0.9 µm of the baffle system at ambient temperature and rocketborne measurements at far-infrared wavelengths of the baffle system at ~3 K. The effective emissivity of the cooled forebaffle was measured to be 7 × 10(-3). The system has been successfully used in rocketborne measurements of the diffuse infrared background and will be used in the Infrared Telescope in Space. PMID:21037777

  6. Cooling system for a gas turbine

    DOEpatents

    Wilson, Ian David; Salamah, Samir Armando; Bylina, Noel Jacob

    2003-01-01

    A plurality of arcuate circumferentially spaced supply and return manifold segments are arranged on the rim of a rotor for respectively receiving and distributing cooling steam through exit ports for distribution to first and second-stage buckets and receiving spent cooling steam from the first and second-stage buckets through inlet ports for transmission to axially extending return passages. Each of the supply and return manifold segments has a retention system for precluding substantial axial, radial and circumferential displacement relative to the rotor. The segments also include guide vanes for minimizing pressure losses in the supply and return of the cooling steam. The segments lie substantially equal distances from the centerline of the rotor and crossover tubes extend through each of the segments for communicating steam between the axially adjacent buckets of the first and second stages, respectively.

  7. Method of fabricating a cooled electronic system

    DOEpatents

    Chainer, Timothy J; Gaynes, Michael A; Graybill, David P; Iyengar, Madhusudan K; Kamath, Vinod; Kochuparambil, Bejoy J; Schmidt, Roger R; Schultz, Mark D; Simco, Daniel P; Steinke, Mark E

    2014-02-11

    A method of fabricating a liquid-cooled electronic system is provided which includes an electronic assembly having an electronics card and a socket with a latch at one end. The latch facilitates securing of the card within the socket. The method includes providing a liquid-cooled cold rail at the one end of the socket, and a thermal spreader to couple the electronics card to the cold rail. The thermal spreader includes first and second thermal transfer plates coupled to first and second surfaces on opposite sides of the card, and thermally conductive extensions extending from end edges of the plates, which couple the respective transfer plates to the liquid-cooled cold rail. The extensions are disposed to the sides of the latch, and the card is securable within or removable from the socket using the latch without removing the cold rail or the thermal spreader.

  8. Excitonic condensation in systems of strongly correlated electrons.

    PubMed

    Kuneš, Jan

    2015-08-26

    The idea of exciton condensation in solids was introduced in the 1960s with the analogy of superconductivity in mind. While exciton supercurrents have been realised only in artificial quantum-well structures so far, the application of the concept of excitonic condensation to bulk solids leads to a rich spectrum of thermodynamic phases with diverse physical properties. In this review we discuss recent developments in the theory of exciton condensation in systems described by Hubbard-type models. In particular, we focus on the connections to their various strong-coupling limits that have been studied in other contexts, e.g. cold atoms physics. One of our goals is to provide a 'dictionary' that would allow the reader to efficiently combine results obtained in these different fields. PMID:26218828

  9. Excitonic condensation in systems of strongly correlated electrons

    NASA Astrophysics Data System (ADS)

    Kuneš, Jan

    2015-08-01

    The idea of exciton condensation in solids was introduced in the 1960s with the analogy of superconductivity in mind. While exciton supercurrents have been realised only in artificial quantum-well structures so far, the application of the concept of excitonic condensation to bulk solids leads to a rich spectrum of thermodynamic phases with diverse physical properties. In this review we discuss recent developments in the theory of exciton condensation in systems described by Hubbard-type models. In particular, we focus on the connections to their various strong-coupling limits that have been studied in other contexts, e.g. cold atoms physics. One of our goals is to provide a ‘dictionary’ that would allow the reader to efficiently combine results obtained in these different fields.

  10. Method for passive cooling liquid metal cooled nuclear reactors, and system thereof

    DOEpatents

    Hunsbedt, Anstein; Busboom, Herbert J.

    1991-01-01

    A liquid metal cooled nuclear reactor having a passive cooling system for removing residual heat resulting from fuel decay during reactor shutdown. The passive cooling system comprises a plurality of partitions surrounding the reactor vessel in spaced apart relation forming intermediate areas for circulating heat transferring fluid which remove and carry away heat from the reactor vessel.

  11. Solar Assisted Adsorptive Desiccant Cooling System

    NASA Astrophysics Data System (ADS)

    Ohkura, Masashi; Kodama, Akio

    Solar assisted desiccant coo1ing process is an effective means to reduce a latent heat load of the ventilation air. This paper describes the influences of ambient humidity and sensible heat factor (SHF) of the indoor room on the performance and scale of the desiccant cooling system. Two process configurations termed “ambient air mode” and “mixed air mode” were assumed. At “ambient air mode”, only ambient air is dehumidified and cooled in the desiccant process. The dehumidified air stream is mixed with return air and further cooled in the cooling coil. At “mixed air mode”, ambient air is mixed with return air and this mixed air stream is dehumidified in the desiccant process and cooled at the cooling coil. At “ambient air mode”, ambient air humidity had a significant impact on required amount of dehumidification since humid ambient air entered the desiccant process directly. In this case, higher temperature level and quantity, which is impossible to be supplied from commonly commercialized flat panel solar collectors, was required. At “mixed air mode”, the influence of increase of ambient humidity was not significant since humidity of the air entering the desiccant process became low by mixing with return air. At this mode, it was expected that 70°C of the circulating water and 37m2 of surface area of solar collector could produce a sufficient dehumidifying performance even in high latent heat condition. The contributing ratio of the desiccant wheel was also estimated. The ratio increased in higher latent heat condition due to increase of required amount of dehumidification. The contributing ratio of the thermal wheel became lower due to increase of saturated air temperature in the evaporative cooler.

  12. Narcissus analysis for cooled staring IR system

    NASA Astrophysics Data System (ADS)

    He, Feng-Yun; Cui, Ji-Cheng; Feng, Shu-Long; Zhang, Xin

    2007-12-01

    Narcissus can have a deleterious effect on image quality for cooled infrared imaging systems. Therefore, analysis of narcissus is important for designing both scanning and staring optics. Narcissus is generally assumed to be negligible in staring IR optical designs because the shading effects can be removed by calibration of the detector array data. However, the calibration usually decreases sensitiveness of the system and Narcissus variation may be noticeable for sensors when the conditions changes as follows: 1. warming and cooling the optical housing, 2. zooming optical elements, 3. movement of lenses for focus. In that case, it will result in shading and other image defects even after calibration. To minimize these effects, narcissus should be assessed and controlled during the design of staring array IR system. We provided a direct and fast method for analyzing the narcissus variation in the presence of software such as LightTools, TracePro and ASAP, and proposed the principles in optical design of staring IR systems to reduce narcissus. A cooled staring IR system with serious narcissus was estimated and reoptimized. Narcissus analysis of this IR system confirmed the efficiency of the analysis method.

  13. Direct observations of plasma upflows and condensation in a catastrophically cooling solar transition region loop

    SciTech Connect

    Orange, N. B.; Chesny, D. L.; Oluseyi, H. M.; Hesterly, K.; Patel, M.; Champey, P.

    2013-12-01

    Minimal observational evidence exists for fast transition region (TR) upflows in the presence of cool loops. Observations of such occurrences challenge notions of standard solar atmospheric heating models as well as their description of bright TR emission. Using the EUV Imaging Spectrometer on board Hinode, we observe fast upflows (v {sub λ} ≤ –10 km s{sup –1}) over multiple TR temperatures (5.8 ≤log T ≤ 6.0) at the footpoint sites of a cool loop (log T ≤ 6.0). Prior to cool loop energizing, asymmetric flows of +5 km s{sup –1} and –60 km s{sup –1} are observed at footpoint sites. These flows, speeds, and patterns occur simultaneously with both magnetic flux cancellation (at the site of upflows only) derived from the Solar Dynamics Observatory's Helioseismic Magnetic Imager's line-of-sight magnetogram images, and a 30% mass influx at coronal heights. The incurred non-equilibrium structure of the cool loop leads to a catastrophic cooling event, with subsequent plasma evaporation indicating that the TR is the heating site. From the magnetic flux evolution, we conclude that magnetic reconnection between the footpoint and background field is responsible for the observed fast TR plasma upflows.

  14. Condensation Risk of Mechanically Attached Roof Systems in Cold Climate Zones

    SciTech Connect

    Pallin, Simon B

    2013-01-01

    systems with thermoplastic membranes are prone to be more effected by interior air intrusion into the roof construction; both due to the wind induced pressure differences and due to the flexibility and elasticity of the membrane (Molleti, Baskaran, Kalinger, & Beaulieu, 2011). Depending on the air permeability of the material underneath the membrane, wind forces increase the risk of fluttering (also referred as billowing) of the thermoplastic membrane. Expectably, the wind induced pressure differences creates a convective air flow into the construction i.e. Page 2 air intrusion. If the conditions are right, moisture from the exchanging air may condensate on surfaces with a temperature below dew-point. The definite path of convective airflows through the building envelope is usually very difficult to determine and therefore simplified models (K nzel, Zirkelbach, & Scfafaczek, 2011) help to estimate an additional moisture loads as a result of the air intrusion. The wind uplifting pressure in combination with wind gusts are important factors for a fluttering roof. Unfortunately, the effect from a fluctuating wind is difficult to estimate as this is a highly dynamic phenomenon and existing standards (ASTM, 2011a) only take into account a steady state approach i.e. there is no guidance or regulations on how to estimate the air intrusion rate. Obviously, a more detailed knowledge on the hygrothermal performance of mechanically attached cool roof system is requested; in consideration to varying surface colors, roof air tightness, climate zones and indoor moisture supply.

  15. Measuring Entanglement in Condensed Matter Systems

    SciTech Connect

    Cramer, M.; Wunderlich, H.; Plenio, M. B.

    2011-01-14

    We show how entanglement may be quantified in spin and cold atom many-body systems using standard experimental techniques only. The scheme requires no assumptions on the state in the laboratory, and a lower bound to the entanglement can be read off directly from the scattering cross section of neutrons deflected from solid state samples or the time-of-flight distribution of cold atoms in optical lattices, respectively. This removes a major obstacle which so far has prevented the direct and quantitative experimental study of genuine quantum correlations in many-body systems: The need for a full characterization of the state to quantify the entanglement contained in it. Instead, the scheme presented here relies solely on global measurements that are routinely performed and is versatile enough to accommodate systems and measurements different from the ones we exemplify in this work.

  16. Personal cooling systems: Possibilities and limitations

    NASA Technical Reports Server (NTRS)

    Nunneley, Sarah A.

    1994-01-01

    Personal thermal control by means of gas- or liquid-conditioned garments was developed during the 1960s and has been applied in a variety of aerospace and industrial settings. Both USAF fighter pilots and astronauts are required to wear heavy protective clothing which insulates them from the environment and thus creates stress through storage of metabolic heat. The problem is particularly severe in astronauts who perform heavy physical work during extra-vehicular activity (EVA); without artificial cooling they could reach incapacitating hyperthermia in a matter of minutes. This paper reviews the factors which influence the design of personal cooling systems. An important early step is determination of acceptable heat stress level, taking into account possible interactions of heat stress with other physiological problems such as motion sickness, diminished plasma volume, decompression sickness and acceleration tolerance. Other factors which require consideration include the work schedule, the area to be covered by the cooling garment, and the practicalities of a fixed or body-mounted heat sink and its power source. Nearly every imaginable heat sink has been proposed or tried over the past 30 years, including direct gas systems, phase-change systems with open or closed loops and thermoelectric heat sinks. The latter are now the system of choice for aircraft.

  17. CONSTANT VOLUME SAMPLING SYSTEM WATER CONDENSATION

    EPA Science Inventory

    Combustion of organic motor vehicle fuels produces carbon dioxide and water (H2O) vapor (and also products of incomplete combustion, e.g. hydrocarbons and carbon monoxide, at lower concentrations). he Constant Volume Sampling (CVS) system, commonly used to condition auto exhaust ...

  18. Condenser on-line leak-detection system development

    SciTech Connect

    Not Available

    1991-11-01

    Condenser tube leaks have been the number one source of impurities in most utility steam cycles. The impurities lead to corrosion of feedwater systems, boilers, and turbines. EPRI recommends sodium in the condensate be less than 3 ppb, which means less than one gallon leakage per day in some cases. The location of leaks requires isolation of the condenser water box and is costly because of power reduction. On-line detection using tracer can cut down the isolation time and, therefore, offers cost advantages to utilities. The on-line leak detection technique utilizes the concepts developed by EPRI for targeted chlorination''. Sulfur hexafluoride (SF{sub 6}), helium gases, and perfluorocarbon liquid were considered as tracers. Laboratory studies were conducted to evaluate the practicability of injecting water with dissolved SF{sub 6} gas, SF{sub 6} bubbles, and dissolved SF{sub 6} gas in perfluorocarbon liquid. Both static and dynamic tests were conducted in a condenser model. It was determined that water entrained with SF{sub 6} bubbles offered the most practical method of injection, followed by dissolved SF{sub 6} gas in perfluorocarbon. A conceptual design was developed that utilizes a water lance, a swivel arrangement in the waterbox manhole cover, a tracer targeting and mixing system, and a tracer gas detection system at the air ejector exhaust. A successful demonstration of targeted leak detection using a waterjet lance with SF{sub 6} was conducted at Carolina Power Light Company's Asheville Steam Electric Station Unit 1. A measurable artificially created leak was detected and located using this system with the condenser on-line. 2 refs., 39 figs., 6 tabs.

  19. Cooling system for high speed aircraft

    NASA Technical Reports Server (NTRS)

    Lawing, P. L.; Pagel, L. L. (Inventor)

    1981-01-01

    The system eliminates the necessity of shielding an aircraft airframe constructed of material such as aluminum. Cooling is accomplished by passing a coolant through the aircraft airframe, the coolant acting as a carrier to remove heat from the airframe. The coolant is circulated through a heat pump and a heat exchanger which together extract essentially all of the added heat from the coolant. The heat is transferred to the aircraft fuel system via the heat exchanger and the heat pump. The heat extracted from the coolant is utilized to power the heat pump. The heat pump has associated therewith power turbine mechanism which is also driven by the extracted heat. The power turbines are utilized to drive various aircraft subsystems, the compressor of the heat pump, and provide engine cooling.

  20. Evaporative Cooling and Dehumidification Garment for Portable Life Support Systems

    NASA Technical Reports Server (NTRS)

    Izenson, Michael; Chen, Weibo; Bue, Grant

    2013-01-01

    This paper describes the design and development of an innovative thermal and humidity control system for future space suits. The system comprises an evaporation cooling and dehumidification garment (ECDG) and a lithium chloride absorber radiator (LCAR). The ECDG absorbs heat and water vapor from inside the suit pressure garment, while the LCAR rejects heat to space without venting water vapor. The ECDG is built from thin, flexible patches with coversheets made of non-porous, water-permeable membranes that -enclose arrays of vapor flow passages. Water vapor from inside the spacesuit diffuses across the water permeable membranes, enters the vapor flow channels, and then flows to the LCAR, thus dehumidifying the internal volume of the space suit pressure garment. Additional water evaporation inside the ECDG provides cooling for sensible heat loads. -The heat released from condensation and absorption in the LCAR is rejected to the environment by thermal radiation. We have assembled lightweight and flexible ECDG pouches from prototypical materials and measured their performance in a series of separate effects tests under well-controlled, prototypical conditions. Sweating hot plate tests at typical space suit pressures show that ECDG pouches can absorb over 60 W/ft of latent heat and 20 W/ft of sensible heat from the pressure garment environment. These results are in good agreement with the predictions of our analysis models.

  1. Measure Guideline: Evaporative Condensers

    SciTech Connect

    German, A.; Dakin, B.; Hoeschele, M.

    2012-03-01

    The purpose of this measure guideline on evaporative condensers is to provide information on a cost-effective solution for energy and demand savings in homes with cooling loads. This is a prescriptive approach that outlines selection criteria, design and installation procedures, and operation and maintenance best practices. This document has been prepared to provide a process for properly designing, installing, and maintaining evaporative condenser systems as well as understanding the benefits, costs, and tradeoffs.

  2. Preliminary design package for solar heating and cooling systems

    NASA Technical Reports Server (NTRS)

    1978-01-01

    Summarized preliminary design information on activities associated with the development, delivery and support of solar heating and cooling systems is given. These systems are for single family dwellings and commercial applications. The heating/cooling system use a reversible vapor compression heat pump that is driven in the cooling mode by a Rankine power loop, and in the heating mode by a variable speed electric motor. The heating/cooling systems differ from the heating-only systems in the arrangement of the heat pump subsystem and the addition of a cooling tower to provide the heat sink for cooling mode operation.

  3. Advanced solar/gas desiccant cooling system

    NASA Astrophysics Data System (ADS)

    Huskey, B.; Sharp, J.; Venero, A.; Yen, M.

    1982-02-01

    A desiccant cooling system with significantly higher thermal efficiency than current state of the art desiccant systems is studied. The findings and data are based on extensive computer modeling and actual operating test results of an experimental breadboard unit employing an approach developed for the separation of moisture from an airstream using solid desiccants (silica gel). The results confirmed the theoretical concept of efficiency improvement over desiccant concepts and validated the computer model used for sizing and simulating the desiccant process. The results also identified specific components and areas of the system needing improvements such as air seals, wheel drive mechanisms, air distribution and materials.

  4. Low pressure cooling seal system for a gas turbine engine

    DOEpatents

    Marra, John J

    2014-04-01

    A low pressure cooling system for a turbine engine for directing cooling fluids at low pressure, such as at ambient pressure, through at least one cooling fluid supply channel and into a cooling fluid mixing chamber positioned immediately downstream from a row of turbine blades extending radially outward from a rotor assembly to prevent ingestion of hot gases into internal aspects of the rotor assembly. The low pressure cooling system may also include at least one bleed channel that may extend through the rotor assembly and exhaust cooling fluids into the cooling fluid mixing chamber to seal a gap between rotational turbine blades and a downstream, stationary turbine component. Use of ambient pressure cooling fluids by the low pressure cooling system results in tremendous efficiencies by eliminating the need for pressurized cooling fluids for sealing this gap.

  5. Controlled cooling of an electronic system based on projected conditions

    DOEpatents

    David, Milnes P.; Iyengar, Madhusudan K.; Schmidt, Roger R.

    2016-05-17

    Energy efficient control of a cooling system cooling an electronic system is provided based, in part, on projected conditions. The control includes automatically determining an adjusted control setting(s) for an adjustable cooling component(s) of the cooling system. The automatically determining is based, at least in part, on projected power consumed by the electronic system at a future time and projected temperature at the future time of a heat sink to which heat extracted is rejected. The automatically determining operates to reduce power consumption of the cooling system and/or the electronic system while ensuring that at least one targeted temperature associated with the cooling system or the electronic system is within a desired range. The automatically determining may be based, at least in part, on an experimentally obtained model(s) relating the targeted temperature and power consumption of the adjustable cooling component(s) of the cooling system.

  6. Controlled cooling of an electronic system based on projected conditions

    DOEpatents

    David, Milnes P.; Iyengar, Madhusudan K.; Schmidt, Roger R.

    2015-08-18

    Energy efficient control of a cooling system cooling an electronic system is provided based, in part, on projected conditions. The control includes automatically determining an adjusted control setting(s) for an adjustable cooling component(s) of the cooling system. The automatically determining is based, at least in part, on projected power consumed by the electronic system at a future time and projected temperature at the future time of a heat sink to which heat extracted is rejected. The automatically determining operates to reduce power consumption of the cooling system and/or the electronic system while ensuring that at least one targeted temperature associated with the cooling system or the electronic system is within a desired range. The automatically determining may be based, at least in part, on an experimentally obtained model(s) relating the targeted temperature and power consumption of the adjustable cooling component(s) of the cooling system.

  7. A thermodynamic assessment of the potential synthesis of condensed hydrocarbons during cooling and dilution of volcanic gases.

    PubMed

    Zolotov, M Y; Shock, E L

    2000-01-10

    The possibility for abiotic synthesis of condensed hydrocarbons in cooling/diluting terrestrial volcanic gases has been evaluated on the basis of the consideration of metastable chemical equilibria involving gaseous CO, CO2, H2 and H2O. The stabilities of n-alkanes and polycyclic aromatic hydrocarbons (PAHS) have been evaluated for several typical volcanic gas compositions under various conditions for cooling/diluting of quenched volcanic gas. The modeling shows that n-alkanes and PAHs have a thermodynamic potential to form metastably from H2 and CO below approximately 250 degrees C within the stability field of graphite. Despite the predominance of CO2 in volcanic gases, synthesis of hydrocarbons from CO2 and H2 is less favored energetically than from CO and H2. Both low temperature and a high H/C atomic ratio in volcanic gas generally favor stability of hydrocarbons with higher H/C ratios. PAHs are thermodynamically stable at temperatures approximately 10 degrees -50 degrees C higher than large n-alkanes; however, at lower temperatures, PAHs and n-alkanes have similar stabilities and are likely to form metastable mixtures. Both the energetic drive to form hydrocarbons and possible temperatures of formation increase as the oxidation state (fO2) of the volcanic gases decreases and as the cooling/dilution ratios of volcanic gases increase. Synthesis of hydrocarbons is energetically more likely in cooling trapped gases than in ashcloud eruptive columns. Mechanisms for hydrocarbon formation may include Fischer-Tropsch-type synthesis catalyzed by magnetite from solid volcanic products. On the early Earth, Mars, and Jupiter's satellite Europa, several factors would have provided more favorable conditions for hydrocarbon synthesis in volcanic gases than under current terrestrial conditions and might have contributed to the production of organic compounds required for the emergence of life. PMID:11543291

  8. Influence of flow velocity on biofilm growth in a tubular heat exchanger-condenser cooled by seawater.

    PubMed

    Trueba, Alfredo; García, Sergio; Otero, Félix M; Vega, Luis M; Madariaga, Ernesto

    2015-01-01

    The influence of flow velocity (FV) on the heat transfer process in tubes made from AISI 316L stainless steel in a heat exchanger-condenser cooled by seawater was evaluated based on the characteristics of the resulting biofilm that adhered to the internal surface of the tubes at velocities of 1, 1.2, 1.6, and 3 m s(-1). The results demonstrated that at a higher FV, despite being more compact and consistent, the biofilm was thinner with a lower concentration of solids, and smoother, which favoured the heat transfer process within the equipment. However, higher velocities increase the initial cost of the refrigerating water-pumping equipment and its energy consumption cost to compensate for the greater pressure drops produced in the tube. The velocity of 1.6 m s(-1) represented the equilibrium between the advantages and disadvantages of the variables analysed for the test conditions in this study. PMID:26222187

  9. Survey and Alignment of the Fermilab Electron Cooling System

    SciTech Connect

    Oshinowo, Babatunde O'Sheg; Leibfritz, Jerry

    2006-09-01

    The goal of achieving the Tevatron luminosity of 3 x 10{sup 32} cm{sup -2}s{sup -1} requires Electron Cooling in the Recycler Ring to provide an increased flux of antiprotons. The Fermilab Electron Cooling system has been designed to assist accumulation of antiprotons for the Tevatron collider operations. The installation along with the survey and alignment of the Electron Cooling system in the Recycler Ring were completed in November 2004. The Electron Cooling system was fully commissioned in May 2005 and the first cooling of antiprotons was achieved in July 2005. This paper discusses the alignment methodology employed to survey and align the Electron Cooling system.

  10. OPTIMIZATION OF DESIGN SPECIFICATIONS FOR LARGE DRY COOLING SYSTEMS

    EPA Science Inventory

    The report presents a methodology for optimizing design specifications of large, mechanical-draft, dry cooling systems. A multivariate, nonlinear, constrained optimization technique searches for the combination of design variables to determine the cooling system with the lowest a...

  11. A fuselage/tank structure study for actively cooled hypersonic cruise vehicles: Active cooling system analysis

    NASA Technical Reports Server (NTRS)

    Stone, J. E.

    1975-01-01

    The effects of fuselage cross section and structural arrangement on the performance of actively cooled hypersonic cruise vehicles are investigated. An active cooling system which maintains the aircraft's entire surface area at temperatures below 394 K at Mach 6 is developed along with a hydrogen fuel tankage thermal protection system. Thermodynamic characteristics of the actively cooled thermal protection systems established are summarized. Design heat loads and coolant flowrate requirements are defined for each major structural section and for the total system. Cooling system weights are summarized at the major component level. Conclusions and recommendations are included.

  12. Dynamic model for controller design of condensate throttling systems.

    PubMed

    Hu, Yong; Zeng, De-Liang; Liu, Ji-Zhen; Zhao, Zheng; Li, Ya-zhe

    2015-09-01

    Improving the load adjustment rate of coal-fired power plants in China is very important because of grid load fluctuations and the construction of new large-scale power plants connected to the country's power grid. In this paper, a new application of condensate throttling system for rapid load adjustment is proposed on the basis of the characteristics of turbine-stored energy. To ensure effective and safe operation of the condensate throttling system, a non-linear control model is derived through reasonable simplifications of fundamental physical laws, and the model parameters are identified using experimental data from a 660 MW supercritical coal-fired power plant. The model outputs are compared with actual measured data for different unit loads. Results show that the established model's responses strongly correlate with the actual unit's responses and can be used for controller design. PMID:26206068

  13. Pair condensation and bound states in fermionic systems

    SciTech Connect

    Sedrakian, Armen; Clark, John W.

    2006-03-15

    We study the finite temperature-density phase diagram of an attractive fermionic system that supports two-body (dimer) and three-body (trimer) bound states in free space. Using interactions characteristic for nuclear systems, we obtain the critical temperature T{sub c2} for the superfluid phase transition and the limiting temperature T{sub c3} for the extinction of trimers. The phase diagram features a Cooper-pair condensate in the high-density, low-temperature domain which, with decreasing density, crosses over to a Bose condensate of strongly bound dimers. The high-temperature, low-density domain is populated by trimers whose binding energy decreases toward the density-temperature domain occupied by the superfluid and vanishes at a critical temperature T{sub c3}>T{sub c2}.

  14. Applications of lattice QCD techniques for condensed matter systems

    NASA Astrophysics Data System (ADS)

    Buividovich, P. V.; Ulybyshev, M. V.

    2016-08-01

    We review the application of lattice QCD techniques, most notably the Hybrid Monte Carlo (HMC) simulations, to first-principle study of tight-binding models of crystalline solids with strong inter-electron interactions. After providing a basic introduction into the HMC algorithm as applied to condensed matter systems, we review HMC simulations of graphene, which in the recent years have helped to understand the semimetal behavior of clean suspended graphene at the quantitative level. We also briefly summarize other novel physical results obtained in these simulations. Then we comment on the applicability of hybrid Monte Carlo to topological insulators and Dirac and Weyl semimetals and highlight some of the relevant open physical problems. Finally, we also touch upon the lattice strong-coupling expansion technique as applied to condensed matter systems.

  15. Comparison of immersed liquid and air cooling of NASA's Airborne Information Management System

    NASA Technical Reports Server (NTRS)

    Hoadley, A. W.; Porter, A. J.

    1992-01-01

    The Airborne Information Management System (AIMS) is currently under development at NASA Dryden Flight Research Facility. The AIMS is designed as a modular system utilizing surface mounted integrated circuits in a high-density configuration. To maintain the temperature of the integrated circuits within manufacturer's specifications, the modules are to be filled with Fluorinert FC-72. Unlike ground based liquid cooled computers, the extreme range of the ambient pressures experienced by the AIMS requires the FC-72 be contained in a closed system. This forces the latent heat absorbed during the boiling to be released during the condensation that must take within the closed module system. Natural convection and/or pumping carries the heat to the outer surface of the AIMS module where the heat transfers to the ambient air. This paper will present an evaluation of the relative effectiveness of immersed liquid cooling and air cooling of the Airborne Information Management System.

  16. 40 CFR 89.329 - Engine cooling system.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 20 2011-07-01 2011-07-01 false Engine cooling system. 89.329 Section...) CONTROL OF EMISSIONS FROM NEW AND IN-USE NONROAD COMPRESSION-IGNITION ENGINES Emission Test Equipment Provisions § 89.329 Engine cooling system. An engine cooling system is required with sufficient capacity...

  17. 40 CFR 90.307 - Engine cooling system.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 21 2012-07-01 2012-07-01 false Engine cooling system. 90.307 Section...) CONTROL OF EMISSIONS FROM NONROAD SPARK-IGNITION ENGINES AT OR BELOW 19 KILOWATTS Emission Test Equipment Provisions § 90.307 Engine cooling system. An engine cooling system is required with sufficient capacity...

  18. 40 CFR 89.329 - Engine cooling system.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 21 2013-07-01 2013-07-01 false Engine cooling system. 89.329 Section...) CONTROL OF EMISSIONS FROM NEW AND IN-USE NONROAD COMPRESSION-IGNITION ENGINES Emission Test Equipment Provisions § 89.329 Engine cooling system. An engine cooling system is required with sufficient capacity...

  19. 40 CFR 89.329 - Engine cooling system.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 21 2012-07-01 2012-07-01 false Engine cooling system. 89.329 Section...) CONTROL OF EMISSIONS FROM NEW AND IN-USE NONROAD COMPRESSION-IGNITION ENGINES Emission Test Equipment Provisions § 89.329 Engine cooling system. An engine cooling system is required with sufficient capacity...

  20. 40 CFR 90.307 - Engine cooling system.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 21 2013-07-01 2013-07-01 false Engine cooling system. 90.307 Section...) CONTROL OF EMISSIONS FROM NONROAD SPARK-IGNITION ENGINES AT OR BELOW 19 KILOWATTS Emission Test Equipment Provisions § 90.307 Engine cooling system. An engine cooling system is required with sufficient capacity...

  1. 40 CFR 91.307 - Engine cooling system.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 21 2013-07-01 2013-07-01 false Engine cooling system. 91.307 Section...) CONTROL OF EMISSIONS FROM MARINE SPARK-IGNITION ENGINES Emission Test Equipment Provisions § 91.307 Engine cooling system. An engine cooling system is required with sufficient capacity to maintain the engine...

  2. 40 CFR 91.307 - Engine cooling system.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 20 2010-07-01 2010-07-01 false Engine cooling system. 91.307 Section...) CONTROL OF EMISSIONS FROM MARINE SPARK-IGNITION ENGINES Emission Test Equipment Provisions § 91.307 Engine cooling system. An engine cooling system is required with sufficient capacity to maintain the engine...

  3. 40 CFR 90.307 - Engine cooling system.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 20 2011-07-01 2011-07-01 false Engine cooling system. 90.307 Section...) CONTROL OF EMISSIONS FROM NONROAD SPARK-IGNITION ENGINES AT OR BELOW 19 KILOWATTS Emission Test Equipment Provisions § 90.307 Engine cooling system. An engine cooling system is required with sufficient capacity...

  4. 40 CFR 89.329 - Engine cooling system.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 20 2010-07-01 2010-07-01 false Engine cooling system. 89.329 Section...) CONTROL OF EMISSIONS FROM NEW AND IN-USE NONROAD COMPRESSION-IGNITION ENGINES Emission Test Equipment Provisions § 89.329 Engine cooling system. An engine cooling system is required with sufficient capacity...

  5. 40 CFR 90.307 - Engine cooling system.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 20 2010-07-01 2010-07-01 false Engine cooling system. 90.307 Section...) CONTROL OF EMISSIONS FROM NONROAD SPARK-IGNITION ENGINES AT OR BELOW 19 KILOWATTS Emission Test Equipment Provisions § 90.307 Engine cooling system. An engine cooling system is required with sufficient capacity...

  6. 40 CFR 91.307 - Engine cooling system.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 20 2011-07-01 2011-07-01 false Engine cooling system. 91.307 Section...) CONTROL OF EMISSIONS FROM MARINE SPARK-IGNITION ENGINES Emission Test Equipment Provisions § 91.307 Engine cooling system. An engine cooling system is required with sufficient capacity to maintain the engine...

  7. 40 CFR 91.307 - Engine cooling system.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 20 2014-07-01 2013-07-01 true Engine cooling system. 91.307 Section...) CONTROL OF EMISSIONS FROM MARINE SPARK-IGNITION ENGINES Emission Test Equipment Provisions § 91.307 Engine cooling system. An engine cooling system is required with sufficient capacity to maintain the engine...

  8. 40 CFR 89.329 - Engine cooling system.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 20 2014-07-01 2013-07-01 true Engine cooling system. 89.329 Section...) CONTROL OF EMISSIONS FROM NEW AND IN-USE NONROAD COMPRESSION-IGNITION ENGINES Emission Test Equipment Provisions § 89.329 Engine cooling system. An engine cooling system is required with sufficient capacity...

  9. 40 CFR 91.307 - Engine cooling system.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 21 2012-07-01 2012-07-01 false Engine cooling system. 91.307 Section...) CONTROL OF EMISSIONS FROM MARINE SPARK-IGNITION ENGINES Emission Test Equipment Provisions § 91.307 Engine cooling system. An engine cooling system is required with sufficient capacity to maintain the engine...

  10. 40 CFR 90.307 - Engine cooling system.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 20 2014-07-01 2013-07-01 true Engine cooling system. 90.307 Section...) CONTROL OF EMISSIONS FROM NONROAD SPARK-IGNITION ENGINES AT OR BELOW 19 KILOWATTS Emission Test Equipment Provisions § 90.307 Engine cooling system. An engine cooling system is required with sufficient capacity...

  11. Bose-condensed atomic systems with nonlocal interaction potentials

    NASA Astrophysics Data System (ADS)

    Yukalov, V. I.; Yukalova, E. P.

    2016-04-01

    The general approach for describing systems with a Bose-Einstein condensate, where atoms interact through nonlocal pair potentials, is presented. Special attention is paid to nonintegrable potentials, such as the dipolar interaction potential. The potentials that are not absolutely integrable can have not well-defined Fourier transforms. Using formally these not defined Fourier transforms leads to unphysical conclusions. To make the Fourier transform well defined, the interaction potential has to be regularised. This is illustrated by the example of dipolar interactions.

  12. Analysis of Radiant Cooling System Configurations Integrated with Cooling Tower for Different Indian Climatic Zones

    SciTech Connect

    Mathur, Jyotirmay; Bhandari, Mahabir S; Jain, Robin; Srivastava, Prateek

    2016-01-01

    Radiant cooling system has proven to be a low energy consumption system for building cooling needs. This study describes the use of cooling tower in radiant cooling system to improve the overall system efficiency. A comprehensive simulation feasibility study of the application of cooling tower in radiant cooling system was performed for the fifteen cities in different climatic zones of India. It was found that in summer, the wet bulb temperature (WBT) of the different climatic zones except warm-humid is suitable for the integration of cooling tower with radiant cooling system. In these climates, cooling tower can provide on average 24 C to 27 C water In order to achieve the energy saving potential, three different configurations of radiant cooling system have been compared in terms of energy consumption. The different configurations of the radiant cooling system integrated with cooling tower are: (1) provide chilled water to the floor, wall and ceiling mounted tubular installation. (2) provide chilled water to the wall and ceiling mounted tabular installation. In this arrangement a separate chiller has also been used to provide chilled water at 16 C to the floor mounted tubular installation. (3) provide chilled water to the wall mounted tabular installation and a separate chiller is used to provide chilled water at 16 C to the floor and ceiling mounted tabular installation. A dedicated outdoor air system is also coupled for dehumidification and ventilation in all three configurations. A conventional all-air system was simulated as a baseline to compare these configurations for assessing the energy saving potential.

  13. Polk power station syngas cooling system

    SciTech Connect

    Jenkins, S.D.

    1995-01-01

    Tampa Electric Company (TEC) is in the site development and construction phase of the new Polk Power Station Unit No. 1. This will be the first unit at a new site and will use Integrated Gasification Combined Cycle (IGCC) Technology. The unit will utilize Texaco`s oxygen-blown, entrained-flow coal gasification, along with combined cycle power generation, to produce nominal 260MW. Integral to the gasification process is the syngas cooling system. The design, integration, fabrication, transportation, and erection of this equipment have provided and continue to provide major challenges for this project.

  14. Electromechanically cooled germanium radiation detector system

    NASA Astrophysics Data System (ADS)

    Lavietes, Anthony D.; Joseph Mauger, G.; Anderson, Eric H.

    1999-02-01

    We have successfully developed and fielded an electromechanically cooled germanium radiation detector (EMC-HPGe) at Lawrence Livermore National Laboratory (LLNL). This detector system was designed to provide optimum energy resolution, long lifetime, and extremely reliable operation for unattended and portable applications. For most analytical applications, high purity germanium (HPGe) detectors are the standard detectors of choice, providing an unsurpassed combination of high energy resolution performance and exceptional detection efficiency. Logistical difficulties associated with providing the required liquid nitrogen (LN) for cooling is the primary reason that these systems are found mainly in laboratories. The EMC-HPGe detector system described in this paper successfully provides HPGe detector performance in a portable instrument that allows for isotopic analysis in the field. It incorporates a unique active vibration control system that allows the use of a Sunpower Stirling cycle cryocooler unit without significant spectral degradation from microphonics. All standard isotopic analysis codes, including MGA and MGA++ [1], GAMANL [2], GRPANL [3]and MGAU [4], typically used with HPGe detectors can be used with this system with excellent results. Several national and international Safeguards organisations including the International Atomic Energy Agency (IAEA) and U.S. Department of Energy (DOE) have expressed interest in this system. The detector was combined with custom software and demonstrated as a rapid Field Radiometric Identification System (FRIS) for the U.S. Customs Service [5]. The European Communities' Safeguards Directorate (EURATOM) is field-testing the first Safeguards prototype in their applications. The EMC-HPGe detector system design, recent applications, and results will be highlighted.

  15. Refrigerant pressurization system with a two-phase condensing ejector

    DOEpatents

    Bergander, Mark

    2009-07-14

    A refrigerant pressurization system including an ejector having a first conduit for flowing a liquid refrigerant therethrough and a nozzle for accelerating a vapor refrigerant therethrough. The first conduit is positioned such that the liquid refrigerant is discharged from the first conduit into the nozzle. The ejector includes a mixing chamber for condensing the vapor refrigerant. The mixing chamber comprises at least a portion of the nozzle and transitions into a second conduit having a substantially constant cross sectional area. The condensation of the vapor refrigerant in the mixing chamber causes the refrigerant mixture in at least a portion of the mixing chamber to be at a pressure greater than that of the refrigerant entering the nozzle and greater than that entering the first conduit.

  16. GENOTOXICITY OF TEN CIGARETTE SMOKE CONDENSATES IN FOUR TEST SYSTEMS: COMPARISONS BETWEEN ASSAYS AND CONDENSATES

    EPA Science Inventory

    What is the study?
    This the first assessment of a set of cigarette smoke condensates from a range of cigarette types in a variety (4) of short-term genotoxicity assays.
    Why was it done?
    No such comparative study of cigarette smoke condensates has been reported. H...

  17. Solar heating and cooling system design and development

    NASA Technical Reports Server (NTRS)

    1978-01-01

    The development of eight prototype solar heating and combined heating and cooling systems is reported. Manufacture, test, installation, maintenance, problem resolution, and monitoring the operation of prototype systems is included. Heating and cooling equipment for single family residential and commercial applications and eight operational test sites (four heating and four heating and cooling) is described.

  18. Solar heating and cooling systems design and development

    NASA Technical Reports Server (NTRS)

    1977-01-01

    The development and delivery of eight prototype solar heating and cooling systems for installation and operational test was reported. Two heating and six heating and cooling units will be delivered for single family residences, multiple family residences and commercial applications.

  19. Integrated exhaust gas recirculation and charge cooling system

    SciTech Connect

    Wu, Ko-Jen

    2013-12-10

    An intake system for an internal combustion engine comprises an exhaust driven turbocharger configured to deliver compressed intake charge, comprising exhaust gas from the exhaust system and ambient air, through an intake charge conduit and to cylinders of the internal combustion engine. An intake charge cooler is in fluid communication with the intake charge conduit. A cooling system, independent of the cooling system for the internal combustion engine, is in fluid communication with the intake charge cooler through a cooling system conduit. A coolant pump delivers a low temperature cooling medium from the cooling system to and through the intake charge cooler for the transfer of heat from the compressed intake charge thereto. A low temperature cooler receives the heated cooling medium through the cooling system conduit for the transfer or heat therefrom.

  20. New Directions for Evaporative Cooling Systems.

    ERIC Educational Resources Information Center

    Robison, Rita

    1981-01-01

    New energy saving technology can be applied to older cooling towers; in addition, evaporative chilling, a process that links a cooling tower to the chilling equipment, can reduce energy use by 80 percent. (Author/MLF)

  1. Variable speed, condensing steam turbine and power system

    SciTech Connect

    Kelly, D.A.

    1980-09-30

    The variable speed condensing steam turbine is a simplified and effective steam expander which is built mainly of simple, lowcost sheet metal parts and is designed to provide a variable speed/torque output range. The turbine concept is based on the past tesla turbine principle of equally spaced rotor discs to provide a long helical path for steam expansion with high operating efficiency and minimum friction. Unlike the cylindrical tesla turbine this unit is in conical form with uniformly varying diameter discs used to provide a variable speed/torque power output range. A further purpose of having a uniform conical housing and uniformly increasing diameter discs is to achieve maximum steam expansion which will lead to rapid steam condensation, or a precondensation condition for the expended steam passing through the conical turbine. A fuel conservation feature of the condensing turbine is a provision for separating hydrogen gas from a portion of the expanded/expended steam which will be conducted to the external fuel burner of the vapor generator, as part of the complete power system.

  2. Effect of spontaneous condensation on condensation heat transfer in the presence of non-condensable gases

    SciTech Connect

    Karl, J.; Hein, D.

    1999-07-01

    The presence of non condensable gases like nitrogen or air reduces the condensation heat transfer during condensation of binary steam mixtures. The non condensable gas accumulates in the vapor phase boundary layer and causes a high heat transfer resistance. Especially with high pressures and low water temperatures spontaneous condensation reduces heat transfer additionally. Fog forms within the steam-nitrogen boundary layer and the steam condenses on the water droplets of the fog layer. The convective mass transfer to the cooling water interface diminishes. Raman spectroscopy and film theory are used to quantify this effect locally. The calculation of overall condensation rates in large steam nitrogen systems requires to use three dimensional CFD codes. The paper presents equations to predict fog formation in the boundary layer which can be implemented in CFD codes.

  3. Enhancing Condensers for Geothermal Systems: the Effect of High Contact Angles on Dropwise Condensation Heat Transfer

    SciTech Connect

    Kennedy, John M.; Kim, Sunwoo; Kim, Kwang J.

    2009-10-06

    Phase change heat transfer is notorious for increasing the irreversibility of, and therefore decreasing the efficiency of, geothermal power plants. Its significant contribution to the overall irreversibility of the plant makes it the most important source of inefficiency in the process. Recent studies here have shown the promotion of drop wise condensation in the lab by means of increasing the surface energy density of a tube with nanotechnology. The use of nanotechnology has allowed the creation of surface treatments which discourage water from wetting a tube surface during a static test. These surface treatments are unique in that they create high- contact angles on the condensing tube surfaces to promote drop wise condensation.

  4. Open cycle lithium chloride cooling system

    NASA Astrophysics Data System (ADS)

    Lenz, T. G.; Loef, G. O. G.; Iyer, R.; Wenger, J.

    1983-05-01

    A lithium chloride open cycle absorption chiller has been designed, built and tested. Solution reconcentration takes place in a small counter current packed column supplied with solar heated air. Removal of noncondensable gases that enter the chiller dissolved in the strong solution and the make-up refrigerant streams is accomplished by a liquid-jet ejector and a small vacuum pump. Cooling capacities approaching 1.4 tons and COP levels of 0.58 have been achieved at non-optimum operating conditions. Test results from preliminary system operation suggest that mass transfer processes in both the packed column reconcentrator and the absorber are controlled by concentration gradients in the lithium chloride solution. Liquid phase controlled mass transfer dictates an operating strategy different from the previously assumed gas phase controlled process to obtain maximum rates of evaporation in the packed column. Determination of optimal operating conditions leading to decreased electrical power consumption and improved cooling capacity and coefficient of performance will require further analysis and testing.

  5. Properties of the Carrol system and a machine design for solar-powered, air cooled, absorption space cooling

    NASA Astrophysics Data System (ADS)

    1981-05-01

    The name Carrol was selected as a convenient shorthand designation for a prime candidate chemical system comprising ethylene glycol-lithium bromide as an absorbent mixture with water as a refrigerant. The instrumentation, methods of handling data and numerical results from a systematic determination of Carrol property data required to design an air cooled absorption machine based on this chemical system are described. These data include saturation temperature, relative enthalpy, density, specific heat capacity, thermal conductivity, viscosity and absorber film heat transfer coefficient as functions of solution temperature and Carrol concentration over applicable ranges. For each of the major components of the absorption chiller, i.e., generator, chiller, absorber, condenser, heat exchanger, purge and controls, the report contains an assembly drawing and the principal operating characteristics of that component.

  6. 8-megapixel thermoelectrically cooled CCD imaging system

    NASA Astrophysics Data System (ADS)

    Diercks, Alan H.; Angione, John; Stubbs, Christopher W.; Cook, Kem H.; Bowell, Edward; Koehn, Bruce W.; Nye, Ralph A.; Dodgen, Dave

    1995-03-01

    We are developing an astronomical imaging system which employs a thermoelectrically cooled focal plane consisting of two 'edge-buttable' Loral 2048 X 2048 pixel CCDs. To allow strip scanning, the columns of the CCDs are mutually aligned on a custom Kovar mount. The clocking and bias voltage levels for each CCD are independently adjustable, but both CCDs are operated synchronously. Each chip is read out from one output and measured at 14 bits with commercially available A/D converters at a rate of 250 kpixels/s, permitting scanning across the sky at up to 1000 deg2/hr (about twenty times faster than the equatorial sidereal rate) to a limiting magnitude (S/N equals 3) near V equals 19. The instrument will be used as part of the Lowell Observatory Near-Earth-Object Search (LONEOS) using a 57-cm Schmidt telescope at Lowell Observatory in Flagstaff, Arizona.

  7. Design of Transpiration Cooled Thermal Protection Systems

    NASA Technical Reports Server (NTRS)

    Callens, E. Eugene, Jr.; Vinet, Robert F.

    1999-01-01

    This study explored three approaches for the utilization of transpiration cooling in thermal protection systems. One model uses an impermeable wall with boiling water heat transfer at the backface (Model I). A second model uses a permeable wall with a boiling water backface and additional heat transfer to the water vapor as it flows in channels toward the exposed surface (Model II). The third model also uses a permeable wall, but maintains a boiling condition at the exposed surface of the material (Model III). The governing equations for the models were developed in non-dimensional form and a comprehensive parametric investigation of the effects of the independent variables on the important dependent variables was performed. In addition, detailed analyses were performed for selected materials to evaluate the practical limitations of the results of the parametric study.

  8. Development of a condenser for the dual catalyst water recovery system

    NASA Technical Reports Server (NTRS)

    Budinikas, P.; Rasouli, F.; Rabadi, N.

    1983-01-01

    Conceptual evaporation/condensation systems suitable for integration with the catalytic water recovery method were evaluated. The primary requirements for each concept were its capability to operate under zero-gravity conditions, condense recovered water from a vapor-noncondensable gas mixture, and integrate with the catalytic system. Specific energy requirements were estimated for concepts meeting the primary requirements, and the concept most suitable for integration with the catalytic system was proposed. A three-man rate condenser capable of integration with the proposed system, condensing water vapor in presence of noncondensables and transferring the heat of condensation to feed urine was designed, fabricated, and tested. It was treated with steam/air mixtures at atmospheric and elevated pressures and integrated with an actual catalytic water recovery system. The condenser has a condensation efficiency exceeding 90% and heat transfer rate of approximately 85% of theoretical value at coolant temperature ranging from 7 to 80 deg C.

  9. Intelligent Engine Systems: Thermal Management and Advanced Cooling

    NASA Technical Reports Server (NTRS)

    Bergholz, Robert

    2008-01-01

    The objective of the Advanced Turbine Cooling and Thermal Management program is to develop intelligent control and distribution methods for turbine cooling, while achieving a reduction in total cooling flow and assuring acceptable turbine component safety and reliability. The program also will develop embedded sensor technologies and cooling system models for real-time engine diagnostics and health management. Both active and passive control strategies will be investigated that include the capability of intelligent modulation of flow quantities, pressures, and temperatures both within the supply system and at the turbine component level. Thermal management system concepts were studied, with a goal of reducing HPT blade cooling air supply temperature. An assessment will be made of the use of this air by the active clearance control system as well. Turbine component cooling designs incorporating advanced, high-effectiveness cooling features, will be evaluated. Turbine cooling flow control concepts will be studied at the cooling system level and the component level. Specific cooling features or sub-elements of an advanced HPT blade cooling design will be downselected for core fabrication and casting demonstrations.

  10. An objective method for screening and selecting personal cooling systems based on cooling properties.

    PubMed

    Elson, John; Eckels, Steve

    2015-05-01

    A method is proposed for evaluation and selection of a personal cooling system (PCS) incorporating PCS, subject, and equipment weights; PCS run time; user task time; PCS cooling power; and average metabolic rate. The cooling effectiveness method presented is derived from first principles and allows those who select PCSs for specific applications to compare systems based on their projected use. This can lower testing costs by screening for the most applicable system. Methods to predict cooling power of PCSs are presented and are compared to data taken through standard manikin testing. The cooling effectiveness ranking is presented and validated against human subject test data. The proposed method provides significant insight into the application of PCS on humans. However, the interaction a humans with a PCS is complex, especially considering the range of clothing ensembles, physiological issues, and end use scenarios, and requires additional analysis. PMID:25683529

  11. High gliding fluid power generation system with fluid component separation and multiple condensers

    SciTech Connect

    Mahmoud, Ahmad M; Lee, Jaeseon; Radcliff, Thomas D

    2014-10-14

    An example power generation system includes a vapor generator, a turbine, a separator and a pump. In the separator, the multiple components of the working fluid are separated from each other and sent to separate condensers. Each of the separate condensers is configured for condensing a single component of the working fluid. Once each of the components condense back into a liquid form they are recombined and exhausted to a pump that in turn drives the working fluid back to the vapor generator.

  12. Passive cooling system for nuclear reactor containment structure

    DOEpatents

    Gou, Perng-Fei; Wade, Gentry E.

    1989-01-01

    A passive cooling system for the contaminant structure of a nuclear reactor plant providing protection against overpressure within the containment attributable to inadvertent leakage or rupture of the system components. The cooling system utilizes natural convection for transferring heat imbalances and enables the discharge of irradiation free thermal energy to the atmosphere for heat disposal from the system.

  13. Natural circulating passive cooling system for nuclear reactor containment structure

    DOEpatents

    Gou, Perng-Fei; Wade, Gentry E.

    1990-01-01

    A passive cooling system for the contaminant structure of a nuclear reactor plant providing protection against overpressure within the containment attributable to inadvertent leakage or rupture of the system components. The cooling system utilizes natural convection for transferring heat imbalances and enables the discharge of irradiation free thermal energy to the atmosphere for heat disposal from the system.

  14. Quantum Monte Carlo Simulation of condensed van der Waals Systems

    NASA Astrophysics Data System (ADS)

    Benali, Anouar; Shulenburger, Luke; Romero, Nichols A.; Kim, Jeongnim; Anatole von Lilienfeld, O.

    2012-02-01

    Van der Waals forces are as ubiquitous as infamous. While post-Hartree-Fock methods enable accurate estimates of these forces in molecules and clusters, they remain elusive for dealing with many-electron condensed phase systems. We present Quantum Monte Carlo [1,2] results for condensed van der Waals systems. Interatomic many-body contributions to cohesive energies and bulk modulus will be discussed. Numerical evidence is presented for crystals of rare gas atoms, and compared to experiments and methods [3]. Sandia National Laboratories is a multiprogram laboratory managed and operated by Sandia Corporation, a wholly owned subsidiary of Lockheed Martin Corporation, for the U.S. DoE's National Nuclear Security Administration under Contract No. DE-AC04-94AL85000.[4pt] [1] J. Kim, K. Esler, J. McMinis and D. Ceperley, SciDAC 2010, J. of Physics: Conference series, Chattanooga, Tennessee, July 11 2011 [0pt] [2] QMCPACK simulation suite, http://qmcpack.cmscc.org (unpublished)[0pt] [3] O. A. von Lillienfeld and A. Tkatchenko, J. Chem. Phys. 132 234109 (2010)

  15. Cooling performance and evaluation of automotive refrigeration system for a passenger car

    NASA Astrophysics Data System (ADS)

    Prajitno, Deendarlianto, Majid, Akmal Irfan; Mardani, Mahardeka Dhias; Wicaksono, Wendi; Kamal, Samsul; Purwanto, Teguh Pudji; Fauzun

    2016-06-01

    A new design of automotive refrigeration system for a passenger car was proposed. To ensure less energy consumption and optimal thermal comfort, the performance of the system were evaluated. This current research was aimed to evaluate the refrigeration characteristics of the system for several types of cooling load. In this present study, a four-passenger wagon car with 1500 cc gasoline engine that equipped by a belt driven compressor (BDC) was used as the tested vehicle. To represent the tropical condition, a set of lamps and wind sources are installed around the vehicle. The blower capacity inside a car is varied from 0.015 m/s to 0.027 m/s and the compressor speed is varied at variable 820, 1400, and 2100 rpm at a set temperature of 22°C. A set of thermocouples that combined by data logger were used to measure the temperature distribution. The system uses R-134a as the refrigerant. In order to determine the cooling capacity of the vehicle, two conditions were presented: without passengers and full load conditions. As the results, cooling capacity from any possible heating sources and transient characteristics of temperature in both systems for the cabin, engine, compressor, and condenser are presented in this work. As the load increases, the outlet temperature of evaporator also increases due to the increase of condensed air. This phenomenon also causes the increase of compressor work and compression ratio which associated to the addition of specific volume in compressor inlet.

  16. Potential of solar cooling systems for peak demand reduction

    SciTech Connect

    Pesaran, A A; Neymark, J

    1994-11-01

    We investigated the technical feasibility of solar cooling for peak demand reduction using a building energy simulation program (DOE2.1D). The system studied was an absorption cooling system with a thermal coefficient of performance of 0.8 driven by a solar collector system with an efficiency of 50% with no thermal storage. The analysis for three different climates showed that, on the day with peak cooling load, about 17% of the peak load could be met satisfactorily with the solar-assisted cooling system without any thermal storage. A performance availability analysis indicated that the solar cooling system should be designed for lower amounts of available solar resources that coincide with the hours during which peak demand reduction is required. The analysis indicated that in dry climates, direct-normal concentrating collectors work well for solar cooling; however, in humid climates, collectors that absorb diffuse radiation work better.

  17. Solar heating and cooling system design and development

    NASA Technical Reports Server (NTRS)

    1978-01-01

    The progress made in the manufacture, test, evaluation, installation, problem resolution, performance evaluation, and development of eight prototype solar heating and combined heating and cooling systems is described.

  18. Prototype solar heating and combined heating and cooling systems

    NASA Technical Reports Server (NTRS)

    1977-01-01

    Eight prototype solar heating and combined heating and cooling systems are being developed. The effort includes development, manufacture, test, installation, maintenance, problem resolution, and performance evaluation.

  19. Prototype solar heating and combined heating and cooling systems

    NASA Technical Reports Server (NTRS)

    1976-01-01

    Eight prototype solar heating and combined heating and cooling systems are considered. This effort includes development, manufacture, test, installation, maintenance, problem resolution, and performance evaluation.

  20. Ice Thermal Storage Systems for LWR Supplemental Cooling and Peak Power Shifting

    SciTech Connect

    Haihua Zhao; Hongbin Zhang; Phil Sharpe; Blaise Hamanaka; Wei Yan; WoonSeong Jeong

    2010-06-01

    Availability of enough cooling water has been one of the major issues for the nuclear power plant site selection. Cooling water issues have frequently disrupted the normal operation at some nuclear power plants during heat waves and long draught. The issues become more severe due to the new round of nuclear power expansion and global warming. During hot summer days, cooling water leaving a power plant may become too hot to threaten aquatic life so that environmental regulations may force the plant to reduce power output or even temporarily to be shutdown. For new nuclear power plants to be built at areas without enough cooling water, dry cooling can be used to remove waste heat directly into the atmosphere. However, dry cooling will result in much lower thermal efficiency when the weather is hot. One potential solution for the above mentioned issues is to use ice thermal storage systems (ITS) that reduce cooling water requirements and boost the plant’s thermal efficiency in hot hours. ITS uses cheap off-peak electricity to make ice and uses those ice for supplemental cooling during peak demand time. ITS is suitable for supplemental cooling storage due to its very high energy storage density. ITS also provides a way to shift large amount of electricity from off peak time to peak time. Some gas turbine plants already use ITS to increase thermal efficiency during peak hours in summer. ITSs have also been widely used for building cooling to save energy cost. Among three cooling methods for LWR applications: once-through, wet cooling tower, and dry cooling tower, once-through cooling plants near a large water body like an ocean or a large lake and wet cooling plants can maintain the designed turbine backpressure (or condensation temperature) during 99% of the time; therefore, adding ITS to those plants will not generate large benefits. For once-through cooling plants near a limited water body like a river or a small lake, adding ITS can bring significant economic

  1. Solar space heating and cooling by selective use of the components of a desiccant cooling system

    NASA Astrophysics Data System (ADS)

    Abbud, Ihsan Aladdin

    The economic advantages of by-passing various components of a desiccant cooling system under conditions not requiring their use are estimated by evaluating the annual costs of heating and cooling a commercial building in three representative U.S. cities. Life-cycle costs of systems employing solar heat for space heating and desiccant regeneration are compared with those using electric heat. The costs of purchasing and operating heating and desiccant cooling systems, with and without solar heat supply, are compared with those employing conventional heating and vapor compression cooling. The conditions under which commercial buildings can be cooled with desiccant systems at costs competitive with conventional systems are identified. A commercially available vapor compression air conditioner is used as a standard of comparison for energy consumption and room comfort. Heating and cooling requirements of the building are determined by use of the BLAST computer model in a simulation of long term system operation. Performance of the desiccant cooling system and life cycle savings obtained by its use are determined by simulation employing the TRNSYS computer model. TRNSYS compatible subroutines are developed to simulate operation of the desiccant equipment, the building, and the controllers that operate and monitor the system components. The results are presented in tabular and graphical form. This study shows that in the widely different climates represented in Los Angeles, New York, and Miami, by-passing various components in the desiccant cooling system when they are not needed is economically advantageous. Operation cost of the complete system decreased by 47.3% in Los Angeles, by 30.9% in New York City, and by 23.9% in Miami by not operating the desiccant wheel and other elements. The ventilation desiccant cooling system has major economic advantage over conventional systems under conditions of moderate humidity, as in Los Angeles and New York City. In Miami, however

  2. Debris trap in a turbine cooling system

    DOEpatents

    Wilson, Ian David

    2002-01-01

    In a turbine having a rotor and a plurality of stages, each stage comprising a row of buckets mounted on the rotor for rotation therewith; and wherein the buckets of at least one of the stages are cooled by steam, the improvement comprising at least one axially extending cooling steam supply conduit communicating with an at least partially annular steam supply manifold; one or more axially extending cooling steam feed tubes connected to the manifold at a location radially outwardly of the cooling steam supply conduit, the feed tubes arranged to supply cooling steam to the buckets of at least one of the plurality of stages; the manifold extending radially beyond the feed tubes to thereby create a debris trap region for collecting debris under centrifugal loading caused by rotation of the rotor.

  3. Nuclear reactor cooling system decontamination reagent regeneration

    DOEpatents

    Anstine, Larry D.; James, Dean B.; Melaika, Edward A.; Peterson, Jr., John P.

    1985-01-01

    An improved method for decontaminating the coolant system of water-cooled nuclear power reactors and for regenerating the decontamination solution. A small amount of one or more weak-acid organic complexing agents is added to the reactor coolant, and the pH is adjusted to form a decontamination solution which is circulated throughout the coolant system to dissolve metal oxides from the interior surfaces and complex the resulting metal ions and radionuclide ions. The coolant containing the complexed metal ions and radionuclide ions is passed through a strong-base anion exchange resin bed which has been presaturated with a solution containing the complexing agents in the same ratio and having the same pH as the decontamination solution. As the decontamination solution passes through the resin bed, metal-complexed anions are exchanged for the metal-ion-free anions on the bed, while metal-ion-free anions in the solution pass through the bed, thus removing the metal ions and regenerating the decontamination solution.

  4. Measured Cooling Performance and Potential for Buried Duct Condensation in a 1991 Central Florida Retrofit Home

    SciTech Connect

    Chasar, Dave; Withers, Charles R.

    2013-02-01

    FSEC conducted energy performance monitoring of two existing residences in Central Florida that were undergoing various retrofits. These homes were occupied by FSEC researchers and were fully instrumented to provide detailed energy, temperature, and humidity measurements. The data provided feedback about the performance of two levels of retrofit in two types of homes in a hot-humid climate. This report covers a moderate-level retrofit and includes two years of pre-retrofit data to characterize the impact of improvements. The other home is a 'deep energy retrofit' (detailed in a separate report) that has performed at near zero energy with a photovoltaic (PV) system and extensive envelope improvements.

  5. GENOTOXICITY OF TEN CIGARETTE SMOKE CONDENSATES IN FOUR TEST SYSTEMS: COMPARISONS AMONG ASSAYS AND CONDENSATES

    EPA Science Inventory

    The particulate fraction of cigarette smoke, cigarette smoke condensate (CSC), is genotoxic in many short-term in vitro tests and carcinogenic in rodents. However, no study has evaluatedd a set of CSCs prepared from a diverse set of cigarettes in a variety of short-term genotoxic...

  6. Heating and Cooling System Design for a Modern Transportable Container

    SciTech Connect

    Berger, Jason E.

    2015-06-01

    Sandia National Laboratories (SNL) has been tasked with the design of a modern transportable container (MTC) for use in high reliability transportation environments. The container is required to transport cargo capable of generating its own heat and operate under the United States’ climatic extremes. In response to these requirements, active heating and cooling is necessary to maintain a controlled environment inside the container. The following thesis project documents the design of an active heating, active cooling, and combined active heating and cooling system (now referred to as active heating and cooling systems) through computational thermal analyses, scoping of commercial system options, and mechanical integration with the container’s structure.

  7. The MANX Muon Cooling Experiment Detection System

    SciTech Connect

    Kahn, S. A.; Abrams, R. J.; Ankenbrandt, C.; Cummings, M. A. C.; Johnson, R. P.; Robertsa, T. J.; Yoneharab, K.

    2010-03-30

    The MANX experiment is being proposed to demonstrate the reduction of 6D muon phase space emittance, using a continuous liquid absorber to provide ionization cooling in a helical solenoid magnetic channel. The experiment involves the construction of a two-period-long helical cooling channel (HCC) to reduce the muon invariant emittance by a factor of two. The HCC would replace the current cooling section of the MICE experiment now being set up at the Rutherford Appleton Laboratory. The MANX experiment would use the existing MICE spectrometers and muon beam line. We discuss the placement of detection planes to optimize the muon track resolution.

  8. Helium cooling systems for large superconducting physics detector magnets

    NASA Astrophysics Data System (ADS)

    Green, M. A.

    The large superconducting detector magnets used for high energy physics experiments are virtually all indirectly cooled. In general, these detector magnets are not cryogenically stabilized. Therefore, there are a number of choices for cooling large indirectly cooled detector magnets. These choices include; 1) forced two-phase helium cooling driven by the helium refrigerator J-T circuit, 2) forced two-phase helium cooling driven by a helium pump, and 3) a peculation gravity feed cooling system which uses liquid helium from a large storage dewar. The choices for the cooling of a large detector magnet are illustrated by applying these concepts to a 4.2 meter diameter 0.5 tesla thin superconducting solenoid for an experiment at the Relativistic Heavy Ion Collider (RHIC).

  9. Improving Vortex Generators to Enhance the Performance of Air-Cooled Condensers in a Geothermal Power Plant

    SciTech Connect

    Manohar S. Sohal

    2005-09-01

    This report summarizes work at the Idaho National Laboratory to develop strategies to enhance air-side heat transfer in geothermal air-cooled condensers such that it should not significantly increase pressure drop and parasitic fan pumping power. The work was sponsored by the U.S. Department of Energy, NEDO (New Energy and Industrial Technology Development Organization) of Japan, Yokohama National University, and the Indian Institute of Technology, Kanpur, India. A combined experimental and numerical investigation was performed to investigate heat transfer enhancement techniques that may be applicable to largescale air-cooled condensers such as those used in geothermal power applications. A transient heat transfer visualization and measurement technique was employed in order to obtain detailed distributions of local heat transfer coefficients on model fin surfaces. Pressure drop measurements were obtained for a variety of tube and winglet configurations using a single-channel flow apparatus that included four tube rows in a staggered array. Heat transfer and pressure drop measurements were also acquired in a separate multiple-tube row apparatus in the Single Blow Test Facility. In addition, a numerical modeling technique was developed to predict local and average heat transfer for these low-Reynolds number flows, with and without winglets. Representative experimental and numerical results were obtained that reveal quantitative details of local finsurface heat transfer in the vicinity of a circular tube with a single delta winglet pair downstream of the cylinder. Heat transfer and pressure-drop results were obtained for flow Reynolds numbers based on channel height and mean flow velocity ranging from 700 to 6500. The winglets were of triangular (delta) shape with a 1:2 or 1:3 height/length aspect ratio and a height equal to 90% of the channel height. Overall mean fin-surface heat transfer results indicate a significant level of heat transfer enhancement (in terms of

  10. Preliminary design activities for solar heating and cooling systems

    NASA Technical Reports Server (NTRS)

    1978-01-01

    Information on the development of solar heating and cooling systems is presented. The major emphasis is placed on program organization, system size definition, site identification, system approaches, heat pump and equipment design, collector procurement, and other preliminary design activities.

  11. Venus Surface Power and Cooling System Design

    NASA Technical Reports Server (NTRS)

    Landis, Geoffrey A.; Mellott, Kenneth D.

    2004-01-01

    A radioisotope power and cooling system is designed to provide electrical power for the a probe operating on the surface of Venus. Most foreseeable electronics devices and sensors simply cannot operate at the 450 C ambient surface temperature of Venus. Because the mission duration is substantially long and the use of thermal mass to maintain an operable temperature range is likely impractical, some type of active refrigeration may be required to keep certain components at a temperature below ambient. The fundamental cooling requirements are comprised of the cold sink temperature, the hot sink temperature, and the amount of heat to be removed. In this instance, it is anticipated that electronics would have a nominal operating temperature of 300 C. Due to the highly thermal convective nature of the high-density atmosphere, the hot sink temperature was assumed to be 50 C, which provided a 500 C temperature of the cooler's heat rejecter to the ambient atmosphere. The majority of the heat load on the cooler is from the high temperature ambient surface environment on Venus. Assuming 5 cm radial thickness of ceramic blanket insulation, the ambient heat load was estimated at approximately 77 watts. With an estimated quantity of 10 watts of heat generation from electronics and sensors, and to accommodate some level of uncertainty, the total heat load requirement was rounded up to an even 100 watts. For the radioisotope Stirling power converter configuration designed, the Sage model predicts a thermodynamic power output capacity of 478.1 watts, which slightly exceeds the required 469.1 watts. The hot sink temperature is 1200 C, and the cold sink temperature is 500 C. The required heat input is 1740 watts. This gives a thermodynamic efficiency of 27.48 %. The maximum theoretically obtainable efficiency is 47.52 %. It is estimated that the mechanical efficiency of the power converter design is on the order of 85 %, based on experimental measurements taken from 500 watt power

  12. Rankine-cycle solar-cooling systems

    NASA Technical Reports Server (NTRS)

    Weathers, H. M.

    1979-01-01

    Report reviews progress made by three contractors to Marshall Space Flight Center and Department of Energy in developing Rankine-cycle machines for solar cooling and testing of commercially available equipment involved.

  13. Design Considerations of a Condensing System for Vaporized Magnesium

    NASA Technical Reports Server (NTRS)

    Witzke, Walter R; Prok, George M; Keller, Thomas A

    1955-01-01

    The effect of the design characteristics of various condensing chambers on magnesium build-up at the chamber inlet was investigated. The condensing chambers are used in the vapor-condensation process for making magnesium slurries. A complete description of the various chamber designs and the procedure used in testing the chambers is given. The results are evaluated on the basis of clogging and total magnesium distilled per run. Orifice design was also considered.

  14. Mechanocaloric and thermomechanical effects in Bose-Einstein-condensed systems

    SciTech Connect

    Marques, G.C.; Bagnato, V.S.; Muniz, S.R.; Spehler, D.

    2004-05-01

    In this paper we extend previous hydrodynamic equations, governing the motion of Bose-Einstein-condensed fluids, to include temperature effects. This allows us to analyze some differences between a normal fluid and a Bose-Einstein-condensed one. We show that, in close analogy with superfluid {sup 4}He, a Bose-Einstein-condensed fluid exhibits the mechanocaloric and thermomechanical effects. In our approach we can explain both effects without using the hypothesis that the Bose-Einstein-condensed fluid has zero entropy. Such ideas could be investigated in existing experiments.

  15. Solar heating and cooling systems design and development. [prototype development

    NASA Technical Reports Server (NTRS)

    1977-01-01

    The development of twelve prototype solar heating/cooling systems, six heating and six heating and cooling systems, two each for single family, multi-family, and commercial applications, is reported. Schedules and technical discussions, along with illustrations on the progress made from April 1, 1977 through June 30, 1977 are detailed.

  16. Get the most out of your cooling system

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Warm weather poses management challenges to maintain production efficiency in broiler chickens. Proper maintenance and operation of ventilation and cooling system components is essential to maintain the proper thermal environment and efficient use of energy. Fan and evaporative cooling system clea...

  17. A hemolysis study of an intravascular blood cooling system for localized organ tissue cooling.

    PubMed

    Merrill, T L; Mingin, T; Merrill, D R; Botbyl, J; Akers, J E

    2013-01-01

    Therapeutic hypothermia can reduce both ischemic and reperfusion injury arising after strokes and heart attacks. New localized organ cooling systems offer a way to reduce tissue damage more effectively with fewer side effects. To assess initial blood safety of our new organ cooling system, the CoolGuide Cooling System (CCS), we investigated safe operating conditions and configurations from a hemolysis perspective. The CCS consists of a peristaltic pump, a custom-built external heat exchanger, a chiller, biocompatible polyvinyl cellulose (PVC) tubing, and a control console. The CCS cools and circulates autologous blood externally and re-delivers cooled blood to the patient through a conventional catheter inserted directly into the organ at risk. Catheter configurations used included: a 7F guide catheter only, a 7F guide with a 0.038" wire inserted through the center and advanced 2 cm distal to the catheter distal tip, a 6F guide catheter only and a 6F guide with a 0.014" guidewire similarly inserted through the center. Using porcine blood, an in vitro test rig was used to measure the degree of hemolysis generation, defined as the percentage change in free hemoglobin, adjusted for total hemoglobin and hematocrit, between exiting and entering blood. The highest degree of hemolysis generation was 0.11±0.04%, based on the average behavior with a 6F catheter and a 0.014" guidewire configuration at a blood flow rate of approximately 130 mL/min. In terms of average percentage free hemoglobin exiting the system, based on total hemoglobin, the highest value measured was 0.17%±0.03%, using this 6F and 0.014" guidewire configuration. This result is significantly below the most stringent European guideline of 0.8% used for blood storage and transfusion. This study provides initial evidence showing hemolysis generation arising from the CoolGuide Cooling System is likely to be clinically insignificant. PMID:23047283

  18. Cooling System Using Natural Circulation for Air Conditioning

    NASA Astrophysics Data System (ADS)

    Okazaki, Takashi; Seshimo, Yu

    In this paper, Cooling systems with natural circulation loop of refrigerants are reviewed. The cooling system can largely reduce energy consumption of a cooling system for the telecommunication base site. The cooling system consists of two refrigeration units; vapor compression refrigeration unit and sub-cooling unit with a natural-circulation loop. The experiments and calculations were carried out to evaluate the cycle performance of natural circulation loop with HFCs and CO2. The experimental results showed that the cooling capacity of R410A is approximately 30% larger than that of R407C at the temperature difference of 20K and the cooling capacity of CO2 was approximately 4-13% larger than that of R410A under the two-phase condition. On the other hand, the cooling capacity of CO2 was approximately 11% smaller than that of R410A under the supercritical condition. The cooling capacity took a maximum value at an amount of refrigerant and lineally increased as the temperature difference increases and the slightly increased as the height difference. The air intake temperature profile in the inlet of the heat exchangers makes the reverse circulation under the supercritical state and the driving head difference for the reverse circulation depends on the density change to temperature under the supercritical state. Also, a new fan control method to convert the reverse circulation into the normal circulation was reviewed.

  19. Cooling system for automotive engine or the like

    SciTech Connect

    Hirano, Y.; Kubozuka, T.

    1986-10-14

    A method is described of cooling an internal combustion engine comprising the steps of: introducing liquid coolant into a cooling circuit which includes a coolant jacket formed about structure of the engine subject to high heat flux; permitting the coolant in the coolant jacket to boil and produce coolant vapor; transferring the coolant vapor to a radiator which defines a further section of the cooling circuit; condensing the coolant to its liquid form in the radiator; sensing operational parameters of the engine; sensing the temperature of the coolant in the coolant jacket; using the data obtained during the step of sensing operational parameters to derive a target temperature at which the coolant in the coolant jacket should be maintained under the instant set of operational conditions; using a device located externally of the radiator to vary the rate of heat exchange between the radiator and a cooling medium surrounding the radiator in a manner which tends to bring the temperature of the coolant to the target temperature; using a reversible pump to pump coolant into and out of the coolant circuit in a manner which varies the pressure prevailing in the cooling circuit in a manner which tends to bring the temperature of the coolant to the target temperature.

  20. Cooling systems for ultra-high temperature turbines.

    PubMed

    Yoshida, T

    2001-05-01

    This paper describes an introduction of research and development activities on steam cooling in gas turbines at elevated temperature of 1500 C and 1700 C level, partially including those on water cooling. Descriptions of a new cooling system that employs heat pipes are also made. From the view point of heat transfer, its promising applicability is shown with experimental data and engine performance numerical evaluation. PMID:11460628

  1. Automotive non-pressure cooling system

    SciTech Connect

    Skinner, A.A.

    1987-07-07

    This patent describes a non-pressure automotive engine cooling system comprising: a radiator containing a liquid coolant, coupling hoses that intercouple the radiator to the engine, pump means associated with the engine for circulating coolant through the engine and radiator. The pump means has a suction side, a radiator cap sealed on the radiator, an expansion tank disposed in the engine compartment, vent means on the tank for venting the tank to atmosphere, a coupling tube disposed between the radiator below the radiator cap and the expansion tank to enable free flow of the coolant under expansion from the radiator to the expansion tank. The radiator cap seals the radiator but provides a substantially non-pressure and unimpeded fluid path from the radiator to the coupling tube, a return line coupled from the expansion tank to the suction side of the pump means. The radiator has a gooseneck with the radiator cap sealably engaged with the gooseneck, an outlet port from the top of the radiator to which the coupling tube is connected. The outlet port is continuously open and unblocked by the radiator cap to provide free fluid flow from the radiator to the expansion tank over the entire operating temperature range, the radiator cap sealing only at the top of the gooseneck, and means for supporting the expansion tank at a position at a height corresponding to the top of the radiator. Under normal temperature operating conditions, the liquid level line is substantially the same in both the radiator and the expansion tank.

  2. A portable personal cooling system for mine rescue operations

    NASA Technical Reports Server (NTRS)

    Webbon, B.; Williams, B.; Kirk, P.; Elkins, W.; Stein, R.

    1977-01-01

    Design of a portable personal cooling system to reduce physiological stress in high-temperature, high-humidity conditions is discussed. The system, based on technology used in the thermal controls of space suits, employs a combination of head and thoracic insulation and cooling through a heat sink unit. Average metabolic rates, heart rates, rectal temperature increase and sweat loss were monitored for test subjects wearing various configurations of the cooling system, as well as for a control group. The various arrangements of the cooling garment were found to provide significant physiological benefits; however, increases in heat transfer rate of the cooling unit and more effective insulation are suggested to improve the system's function.

  3. PERFORMANCE EVALUATION OF CEILING RADIANT COOLING SYSTEM IN COMPOSITE CLIMATE

    SciTech Connect

    Sharma, Anuj; Mathur, Jyotirmay; Bhandari, Mahabir S

    2015-01-01

    Radiant cooling systems are proving to be an energy efficient solution due to higher thermal capacity of cooling fluid especially for the buildings that require individual zone controls and where the latent loads are moderate. The Conventional air conditioners work at very low temperature i.e.5-8 c (refrigerant evaporator inlet) while the radiant cooling systems, also referred as high temperature cooling system, work at high temperatures i.e. 14-18 c. The radiant cooling systems can maintain lower MRT (Mean Radiant Temperature) as ceiling panels maintain uniform temperature gradient inside room and provide higher human comfort. The radiant cooling systems are relatively new systems and their operation and energy savings potential are not quantified for a large number of buildings and operational parameters. Moreover, there are only limited numbers of whole building simulation studies have been carried out for these systems to have a full confidence in the capability of modelling tools to simulate these systems and predict the impact of various operating parameters. Theoretically, savings achieve due to higher temperature set point of chilled water, which reduces chiller-running time. However, conventional air conditioner runs continuously to maintain requisite temperature. In this paper, experimental study for performance evaluation of radiant cooling system carried out on system installed at Malaviya National Institute of Technology Jaipur. This paper quantifies the energy savings opportunities and effective temperature by radiant cooling system at different chilled water flow rates and temperature range. The data collected/ analysed through experimental study will used for calibration and validation of system model of building prepared in building performance simulation software. This validated model used for exploring optimized combinations of key parameters for composite climate. These optimized combinations will used in formulation of radiant cooling system

  4. Evaluation of materials for systems using cooled, treated geothermal or high-saline brines

    SciTech Connect

    Suciu, D.F.; Wikoff, P.M.

    1982-09-01

    Lack of adequate quantities of clean surface water for use in wet (evaporative) cooling systems indicates the use of high-salinity waste waters, or cooled geothermal brines, for makeup purposes. High-chloride, aerated water represents an extremely corrosive environment. In order to determine metals suitable for use in such an environment, metal coupons were exposed to aerated, treated geothermal brine salted to a chloride concentration of 10,000 and 50,000 ppM (mg/L) for periods of up to 30 days. The exposed coupons were evaluated to determine the general, pitting, and crevice corrosion characteristics of the metals. The metals exhibiting corrosion resistance at 50,000 ppM chloride were then evaluated at 100,000 and 200,000 ppM chloride. Since these were screening tests to select materials for components to be used in a cooling system, with primary emphasis on condenser tubing, several materials were exposed for 4 to 10 months in pilot cooling tower test units with heat transfer for further corrosion evaluation. The results of the screening tests indicate that ferritic stainless steels (29-4-2 and SEA-CURE) exhibit excellent corrosion resistance at all levels of chloride concentration. Copper-nickel alloys (70/30 and Monel 400) exhibited excellent corrosion resistance in the high-saline water. The 70/30 copper-nickel alloy, which showed excellent resistance to general corrosion, exhibited mild pitting in the 30-day tests. This pitting was not apparent, however, after 6 months of exposure in the pilot cooling tower tests. The nickel-base alloys exhibited excellent corrosion resistance, but their high cost prevents their use unless no other material is found feasible. Other materials tested, although unsuitable for condenser tubing material, would be suitable as tube sheet material.

  5. Prototype solar heating and combined heating cooling systems

    NASA Technical Reports Server (NTRS)

    1978-01-01

    The design and development of eight prototype solar heating and combined heating and cooling systems is discussed. The program management and systems engineering are reported, and operational test sites are identified.

  6. Solar heating and cooling systems design and development

    NASA Technical Reports Server (NTRS)

    1976-01-01

    Solar heating and heating/cooling systems were designed for single family, multifamily, and commercial applications. Subsystems considered included solar collectors, heat storage systems, auxiliary energy sources, working fluids, and supplementary controls, piping, and pumps.

  7. Solar heating and cooling systems design and development

    NASA Technical Reports Server (NTRS)

    1977-01-01

    Progress in the development of prototype solar heating/cooling systems is reported. Results obtained from refinement/improvement of the single family, multifamily, and commercial systems configurations and generalized studies on several of the subsystems are presented.

  8. Solar heating and cooling technical data and systems analysis

    NASA Technical Reports Server (NTRS)

    Christensen, D. L.

    1977-01-01

    The research activities described herein were concentrated on the areas of economics, heating and cooling systems, architectural design, materials characteristics, climatic conditions, educational information packages, and evaluation of solar energy systems and components.

  9. Closed loop air cooling system for combustion turbines

    DOEpatents

    Huber, D.J.; Briesch, M.S.

    1998-07-21

    Convective cooling of turbine hot parts using a closed loop system is disclosed. Preferably, the present invention is applied to cooling the hot parts of combustion turbine power plants, and the cooling provided permits an increase in the inlet temperature and the concomitant benefits of increased efficiency and output. In preferred embodiments, methods and apparatus are disclosed wherein air is removed from the combustion turbine compressor and delivered to passages internal to one or more of a combustor and turbine hot parts. The air cools the combustor and turbine hot parts via convection and heat is transferred through the surfaces of the combustor and turbine hot parts. 1 fig.

  10. Closed loop air cooling system for combustion turbines

    DOEpatents

    Huber, David John; Briesch, Michael Scot

    1998-01-01

    Convective cooling of turbine hot parts using a closed loop system is disclosed. Preferably, the present invention is applied to cooling the hot parts of combustion turbine power plants, and the cooling provided permits an increase in the inlet temperature and the concomitant benefits of increased efficiency and output. In preferred embodiments, methods and apparatus are disclosed wherein air is removed from the combustion turbine compressor and delivered to passages internal to one or more of a combustor and turbine hot parts. The air cools the combustor and turbine hot parts via convection and heat is transferred through the surfaces of the combustor and turbine hot parts.

  11. Solar residential heating and cooling system development test program

    NASA Technical Reports Server (NTRS)

    Humphries, W. R.; Melton, D. E.

    1974-01-01

    A solar heating and cooling system is described, which was installed in a simulated home at Marshall Space Flight Center. Performance data are provided for the checkout and initial operational phase for key subsystems and for the total system. Valuable information was obtained with regard to operation of a solar cooling system during the first summer of operation. Areas where improvements and modifications are required to optimize such a system are discussed.

  12. Compact Solid State Cooling Systems: Compact MEMS Electrocaloric Module

    SciTech Connect

    2010-10-01

    BEETIT Project: UCLA is developing a novel solid-state cooling technology to translate a recent scientific discovery of the so-called giant electrocaloric effect into commercially viable compact cooling systems. Traditional air conditioners use noisy, vapor compression systems that include a polluting liquid refrigerant to circulate within the air conditioner, absorb heat, and pump the heat out into the environment. Electrocaloric materials achieve the same result by heating up when placed within an electric field and cooling down when removed—effectively pumping heat out from a cooler to warmer environment. This electrocaloric-based solid state cooling system is quiet and does not use liquid refrigerants. The innovation includes developing nano-structured materials and reliable interfaces for heat exchange. With these innovations and advances in micro/nano-scale manufacturing technologies pioneered by semiconductor companies, UCLA is aiming to extend the performance/reliability of the cooling module.

  13. HEATING AND COOLING SYSTEM FOR CALUTRON

    DOEpatents

    Starr, A.M.

    1960-06-28

    An apparatus is invented for heating or cooling the electrostatic liner conventionally disposed in a calutron tank. The apparatus is additionally arranged to mount the liner in its intended position in a readily detachable manner so as to facilitate disassembly of the calutron.

  14. Modelling an actively-cooled CPV system

    NASA Astrophysics Data System (ADS)

    Buonomano, A.; Mittelman, G.; Faiman, D.; Biryukov, S.; Melnichak, V.; Bukobza, D.; Kabalo, S.

    2012-10-01

    We have constructed a 7-node, 1-dimensional model of the heat flow in a water-cooled CPV receiver. The model is validated against data from a module exposed to solar irradiance at various concentrations up to 1,000X at the PETAL solar dish facility at Sede Boqer.

  15. Prototype solar heating and combined heating and cooling systems

    NASA Technical Reports Server (NTRS)

    1977-01-01

    Schedules and technical progress in the development of eight prototype solar heating and combined solar heating and cooling systems are reported. Particular emphasis is given to the analysis and preliminary design for the cooling subsystem, and the setup and testing of a horizontal thermal energy storage tank configuration and collector shroud evaluation.

  16. Cryogenic cooling system for the ground test accelerator

    SciTech Connect

    Edeskuty, F.J.; Stewart, W.F.; Moeller, J.; Durham, F.; Spulgis, I.

    1993-06-01

    A cryogenic cooling system has been designed, built and tested for the Ground Test Accelerator (GTA) at the Los Alamos National Laboratory. Major components of the GTA require cooling to less than 50 K to reduce rf-heating and to increase thermal stability. The cooling system is capable of cooling (at an acceptable rate for thermal stresses) the cryogenically cooled components and then maintaining them at their operating temperature during accelerator testing for all modes and power levels of operation. The accelerator components are cooled by circulating cold, dense helium gas (about 21 K and 2.1 MPa) through the components. The circulating helium is refrigerated in a heat exchanger that uses boiling liquid hydrogen as a source of refrigeration. The cryogenic cooling system consists of the following major components: a liquid hydrogen (LH{sub 2}) storage Dewar with a transfer line to an LH{sub 2} run tank containing an LH{sub 2}/gaseous helium (GHe) heat exchanger, circulation lines, and a circulation pump. The system, sized to cool a load of approximately 40 kW at temperatures as low as 20 K, is operational, but has not yet been operated in conjunction with the accelerator.

  17. Cryogenic cooling system for the ground test accelerator

    SciTech Connect

    Edeskuty, F.J.; Stewart, W.F.; Moeller, J.; Durham, F. ); Spulgis, I. )

    1993-01-01

    A cryogenic cooling system has been designed, built and tested for the Ground Test Accelerator (GTA) at the Los Alamos National Laboratory. Major components of the GTA require cooling to less than 50 K to reduce rf-heating and to increase thermal stability. The cooling system is capable of cooling (at an acceptable rate for thermal stresses) the cryogenically cooled components and then maintaining them at their operating temperature during accelerator testing for all modes and power levels of operation. The accelerator components are cooled by circulating cold, dense helium gas (about 21 K and 2.1 MPa) through the components. The circulating helium is refrigerated in a heat exchanger that uses boiling liquid hydrogen as a source of refrigeration. The cryogenic cooling system consists of the following major components: a liquid hydrogen (LH[sub 2]) storage Dewar with a transfer line to an LH[sub 2] run tank containing an LH[sub 2]/gaseous helium (GHe) heat exchanger, circulation lines, and a circulation pump. The system, sized to cool a load of approximately 40 kW at temperatures as low as 20 K, is operational, but has not yet been operated in conjunction with the accelerator.

  18. Cryogenic cooling system for the Ground Test Accelerator

    SciTech Connect

    Edeskuty, F.J.; Stewart, W.F.; Moeller, J.; Durham, F.; Spulgis, I.

    1994-12-31

    A cryogenic cooling system has been designed, built and tested for the Ground Test Accelerator (GTA) at the Los Alamos National Laboratory. Major components of the GTA require cooling to less than 50 K to reduce rf-heating and to increase thermal stability. The cooling system is capable of cooling (at an acceptable rate for thermal stresses) the cryogenically cooled components and then maintaining them at their operating temperature during accelerator testing for all modes and power levels of operation. The accelerator components are cooled by circulating cold, dense helium gas (about 21 K and 2.1 MPa) through the components. The circulating helium is refrigerated in a heat exchanger that uses boiling liquid hydrogen as a source of refrigeration. The cryogenic cooling system consists of the following major components: a liquid hydrogen (LH{sub 2}) storage Dewar with a transfer line to an LH{sub 2} run tank containing an LH{sub 2}/gaseous helium (GHe) heat exchanger, circulation lines, and a circulation pump. The system, sized to cool a load of approximately 40 kW at temperatures as low as 20 K, is operational, but has not yet been operated in conjunction with the accelerator.

  19. Cryogenic systems for proof of the principle experiment of coherent electron cooling at RHIC

    SciTech Connect

    Huang, Yuenian; Belomestnykh, Sergey; Brutus, Jean Clifford; Lederle, Dewey; Orfin, Paul; Skaritka, John; Soria, Victor; Tallerico, Thomas; Than, Roberto

    2014-01-29

    The Coherent electron Cooling (CeC) Proof of Principle (PoP) experiment is proposed to be installed in the Relativistic Heavy Ion Collider (RHIC) to demonstrate proton and ion beam cooling with this new technique that may increase the beam luminosity in certain cases, by as much as tenfold. Within the scope of this project, a 112 MHz, 2MeV Superconducting Radio Frequency (SRF) electron gun and a 704 MHz 20MeV 5-cell SRF cavity will be installed at IP2 in the RHIC ring. The superconducting RF electron gun will be cooled in a liquid helium bath at 4.4 K. The 704 MHz 5-cell SRF cavity will be cooled in a super-fluid helium bath at 2.0 K. This paper discusses the cryogenic systems designed for both cavities. For the 112 MHz cavity cryogenic system, a condenser/boiler heat exchanger is used to isolate the cavity helium bath from pressure pulses and microphonics noise sources. For the 704 MHz 5-cell SRF cavity, a heat exchanger is also used to isolate the SRF cavity helium bath from noise sources in the sub-atmospheric pumping system operating at room temperature. Detailed designs, thermal analyses and discussions for both systems will be presented in this paper.

  20. Impact of advanced fluids on costs of district cooling systems

    SciTech Connect

    Choi, U.S. ); France, D.M.; Knodel, B.D. Illinois Univ., Chicago, IL . Dept. of Mechanical Engineering)

    1992-01-01

    Three alternate fluids, ice-water slurry, friction reduction additive and the combination of them, have been compared for use in District Cooling Systems (DCS). The effect of the fluids on cost and cooling capacities were considered for the two cases of new and existing DCS separately. Two criteria were used in comparisons among fluids in each case: constant pumping power which allows for the most benefit, and constant velocity which is more practical consideration. An economic assessment for a 500 ton system shows a potential cost difference in the total pipe cost for a new system of 70% when a 30% ice slurry is used in place of chilled water. The pipe diameter is reduced to 40% using the slurry. These results apply to the constant comparison and are independent of the use of additive. Friction reduction additives serve to reduce pumping power and pressure drop. The ice-water slurry also has a significant impact on existing district cooling systems. It can potentially expand the cooling capacity by 500% without new piping being installed while maintaining the same pumping power, velocity and pressure-drop as the chilled water system. Again, friction reduction additives serve to reduce pumping power and pressure-drop. They do not influence cooling capacity. The cost for expanding the piping to increase the cooling capacity by the same amount by the use of conventional district cooling technology has been shown to be extremely high compared to the ice-water slurry system.

  1. Impact of advanced fluids on costs of district cooling systems

    SciTech Connect

    Choi, U.S.; France, D.M.; Knodel, B.D. |

    1992-07-01

    Three alternate fluids, ice-water slurry, friction reduction additive and the combination of them, have been compared for use in District Cooling Systems (DCS). The effect of the fluids on cost and cooling capacities were considered for the two cases of new and existing DCS separately. Two criteria were used in comparisons among fluids in each case: constant pumping power which allows for the most benefit, and constant velocity which is more practical consideration. An economic assessment for a 500 ton system shows a potential cost difference in the total pipe cost for a new system of 70% when a 30% ice slurry is used in place of chilled water. The pipe diameter is reduced to 40% using the slurry. These results apply to the constant comparison and are independent of the use of additive. Friction reduction additives serve to reduce pumping power and pressure drop. The ice-water slurry also has a significant impact on existing district cooling systems. It can potentially expand the cooling capacity by 500% without new piping being installed while maintaining the same pumping power, velocity and pressure-drop as the chilled water system. Again, friction reduction additives serve to reduce pumping power and pressure-drop. They do not influence cooling capacity. The cost for expanding the piping to increase the cooling capacity by the same amount by the use of conventional district cooling technology has been shown to be extremely high compared to the ice-water slurry system.

  2. Prototype solar heating and cooling systems, including potable hot water

    NASA Technical Reports Server (NTRS)

    Bloomquist, D.; Oonk, R. L.

    1977-01-01

    Progress made in the development, delivery, and support of two prototype solar heating and cooling systems including potable hot water is reported. The system consists of the following subsystems: collector, auxiliary heating, potable hot water, storage, control, transport, and government-furnished site data acquisition. A comparison of the proposed Solaron Heat Pump and Solar Desiccant Heating and Cooling Systems, installation drawings, data on the Akron House at Akron, Ohio, and other program activities are included.

  3. Cooling system for three hook ring segment

    SciTech Connect

    Campbell, Christian X.; Eng, Darryl; Lee, Ching-Pang; Patat, Harry

    2014-08-26

    A triple hook ring segment including forward, midsection and aft mounting hooks for engagement with respective hangers formed on a ring segment carrier for supporting a ring segment panel, and defining a forward high pressure chamber and an aft low pressure chamber on opposing sides of the midsection mounting hook. An isolation plate is provided on the aft side of the midsection mounting hook to form an isolation chamber between the aft low pressure chamber and the ring segment panel. High pressure air is supplied to the forward chamber and flows to the isolation chamber through crossover passages in the midsection hook. The isolation chamber provides convection cooling air to an aft portion of the ring segment panel and enables a reduction of air pressure in the aft low pressure chamber to reduce leakage flow of cooling air from the ring segment.

  4. Measured effects of retrofits -- a refrigerant oil additive and a condenser spray device -- on the cooling performance of a heat pump

    SciTech Connect

    Levins, W.P.; Sand, J.R.; Baxter, V.D.; Linkous, R.L.

    1996-05-01

    A 15-year old, 3-ton single package air-to-air heat pump was tested in laboratory environmental chambers simulating indoor and outdoor conditions. After documenting initial performance, the unit was retrofitted with a prototype condenser water-spray device and retested. Results at standard ARI cooling rating conditions (95 F outdoor dry bulb and 80/67 F indoor dry bulb/wet bulb temperatures) showed the capacity increased by about 7%, and the electric power demand dropped by about 8%, resulting in a steady-state EER increase of 17%. Suction and discharge pressures were reduced by 7 and 37 psi, respectively. A refrigerant oil additive formulated to enhance refrigerant-side heat transfer was added at a dose of one ounce per ton of rated capacity, and the unit was tested for several days at the same 95 F outdoor conditions and showed essentially no increase in capacity, and a slight 3% increase in steady-state EER. Adding more additive lowered the EER slightly. Suction and discharge pressures were essentially unchanged. The short-term testing showed that the condenser-spray device was effective in increasing the cooling capacity and lowering the electrical demand on an old and relatively inefficient heat pump, but the refrigerant additive had little effect on the cooling performance of the unit. Sprayer issues to be resolved include the effect of a sprayer on a new, high-efficiency air conditioner/heat pump, reliable long-term operation, and economics.

  5. Design and Control of Hydronic Radiant Cooling Systems

    NASA Astrophysics Data System (ADS)

    Feng, Jingjuan

    Improving energy efficiency in the Heating Ventilation and Air conditioning (HVAC) systems in buildings is critical to achieve the energy reduction in the building sector, which consumes 41% of all primary energy produced in the United States, and was responsible for nearly half of U.S. CO2 emissions. Based on a report by the New Building Institute (NBI), when HVAC systems are used, about half of the zero net energy (ZNE) buildings report using a radiant cooling/heating system, often in conjunction with ground source heat pumps. Radiant systems differ from air systems in the main heat transfer mechanism used to remove heat from a space, and in their control characteristics when responding to changes in control signals and room thermal conditions. This dissertation investigates three related design and control topics: cooling load calculations, cooling capacity estimation, and control for the heavyweight radiant systems. These three issues are fundamental to the development of accurate design/modeling tools, relevant performance testing methods, and ultimately the realization of the potential energy benefits of radiant systems. Cooling load calculations are a crucial step in designing any HVAC system. In the current standards, cooling load is defined and calculated independent of HVAC system type. In this dissertation, I present research evidence that sensible zone cooling loads for radiant systems are different from cooling loads for traditional air systems. Energy simulations, in EnergyPlus, and laboratory experiments were conducted to investigate the heat transfer dynamics in spaces conditioned by radiant and air systems. The results show that the magnitude of the cooling load difference between the two systems ranges from 7-85%, and radiant systems remove heat faster than air systems. For the experimental tested conditions, 75-82% of total heat gain was removed by radiant system during the period when the heater (simulating the heat gain) was on, while for air

  6. Desiccant-based, heat-actuated cooling assessment for DHC (District Heating and Cooling) systems

    SciTech Connect

    Patch, K.D.; DiBella, F.A.; Becker, F.E.

    1990-07-01

    An assessment has been completed of the use of desiccant-based, heat-actuated cooling for District Heating and Cooling (DHC) systems, showing that such desiccant-based cooling (DBC) systems are generally applicable to District Heating (DH) systems. Since the DH system only has to supply hot water (or steam) to its customers, systems that were designed as conventional two-pipe DH systems can now be operated as DHC systems without major additional capital expense. Desiccant-based DHC systems can be operated with low-grade DH-supplied heat, at temperatures below 180{degree}F, without significant loss in operating capacity, relative to absorption chillers. During this assessment, a systems analysis was performed, an experimental investigation was conducted, developmental requirements for commercializing DBC systems were examined, and two case studies were conducted. As a result of the case studies, it was found that the operating cost of a DBC system was competitive with or lower than the cost of purchasing DHC-supplied chilled water. However, because of the limited production volume and the current high capital costs of desiccant systems, the payback period is relatively long. In this regard, through the substitution of low-cost components specifically engineered for low-temperature DHC systems, the capital costs should be significantly reduced and overall economics made attractive to future users. 17 figs.

  7. Cooling and shielding systems for infrared detectors - requirements and limits.

    PubMed

    Wiecek, B

    2005-01-01

    This paper presents three main cooling systems used for infrared detectors. At first thermoelectric devices are discussed. They allow cooling down the detector with low efficiency and not to the very low temperature. They do not generate any vibrations and therefore are suitable for thermal detectors, where the microphone effect can decrease their performance. Photon detectors need to be cooled down even to 77K or better. The only way to have such deep cooling is to use the cooler based on thermodynamic cycle such as Stirling one. With the high efficiency one can easily obtain cryogenic temperature for a detector. The electromagnetic noise and vibration generation are the main disadvantages of using such devices. Joule-Thomson effect during gas expansion is 3rdcooling system discussed in the paper. It is highly effective process, used for gas liquefaction too. The working gas is being removed during cooling into the atmosphere, so the need of continuous supplying with compressed one, what makes this system very difficult for remote applications. In the paper, simple calculations are presented to illustrate the advantages and disadvantages of the different cooling systems. PMID:17282258

  8. Preliminary design package for prototype solar heating and cooling systems

    NASA Technical Reports Server (NTRS)

    1978-01-01

    A summary is given of the preliminary analysis and design activity on solar heating and cooling systems. The analysis was made without site specific data other than weather; therefore, the results indicate performance expected under these special conditions. Major items include a market analysis, design approaches, trade studies and other special data required to evaluate the preliminary analysis and design. The program calls for the development and delivery of eight prototype solar heating and cooling systems for installation and operational test. Two heating and six heating and cooling units will be delivered for Single Family Residences, Multiple-family Residences and commercial applications.

  9. System and method for pre-cooling of buildings

    DOEpatents

    Springer, David A.; Rainer, Leo I.

    2011-08-09

    A method for nighttime pre-cooling of a building comprising inputting one or more user settings, lowering the indoor temperature reading of the building during nighttime by operating an outside air ventilation system followed, if necessary, by a vapor compression cooling system. The method provides for nighttime pre-cooling of a building that maintains indoor temperatures within a comfort range based on the user input settings, calculated operational settings, and predictions of indoor and outdoor temperature trends for a future period of time such as the next day.

  10. Heating and Cooling: Measurement of Temperature for Thermally Connected Systems.

    ERIC Educational Resources Information Center

    Baines, John

    1995-01-01

    Discusses a series of experiments to establish a significance of temperature difference in rates of cooling, to illustrate the connection between energy transfer and the consequent temperature changes for thermally connected systems that are not in equilibrium. (MKR)

  11. 2. VIEW SOUTH OF WIND TUNNEL 138 AND COOLING SYSTEM ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    2. VIEW SOUTH OF WIND TUNNEL 138 AND COOLING SYSTEM 140, NORTH ELEVATION - Naval Surface Warfare Center, Subsonic Wind Tunnel Building, Bounded by Clara Barton Parkway & McArthur Boulevard, Silver Spring, Montgomery County, MD

  12. Detail exterior view looking southwest of gas cooling system. Engine ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Detail exterior view looking southwest of gas cooling system. Engine house is shown in right background. - Burnsville Natural Gas Pumping Station, Saratoga Avenue between Little Kanawha River & C&O Railroad line, Burnsville, Braxton County, WV

  13. Validation of the RVACS (Reactor Vessel Auxiliary Cooling System)/RACS (Reactor Air Cooling System) model in SASSYS-1

    SciTech Connect

    Dunn, F.E.

    1987-01-01

    The SASSYS-1 LMR systems analysis code contains a model for transient analysis of heat removal by a RVACS (Reactor Vessel Auxiliary Cooling System) or a RACS (Reactor Air Cooling System) in an LMR (Liquid Metal Reactor). This model has been validated by comparisons of model predictions with experimental data from a large scale RVACS/RACS simulation experiment performed at Argonne National Laboratory. 4 refs., 1 fig.

  14. Results on studies of soot production and fouling in oil-fired condensing systems

    SciTech Connect

    Butcher, T.; Celebi, Y.; Piraino, M.; McDonald, R.

    1986-01-01

    The development of condensing heat exchangers for oil-fired heating equipment would yield a significant improvement in thermal efficiency. Soot production by oil burners, however, could lead to fouling problems in these systems. Results are reported on tests done to evaluate the effect of operating conditions on start-up and shutdown smoke production in both noncondensing and condensing furnaces.

  15. Developing, testing, evaluating, and optimizing solar heating and cooling systems

    NASA Astrophysics Data System (ADS)

    1992-01-01

    The objective is to develop and test various integrated solar heating, cooling and domestic hot water systems, and to evaluate their performance. Systems composed of new, as well as previously tested, components are carefully integrated so that effects of new components on system performance can be clearly delineated. The SEAL-DOE program includes six tasks which have received funding for the 1991 to 92 fifteen-month period. These include: (1) a project employing isothermal operation of air and liquid solar space heating systems; (2) a project to build and test several generic solar water heaters; (3) a project that will evaluate advanced solar domestic hot water components and concepts and integrate them into solar domestic hot water systems; (4) a liquid desiccant cooling system development project; (5) a project that will perform system modeling and analysis work on solid desiccant cooling systems research; and (6) a management task. The objectives and progress in each task are described in this report.

  16. Developing, testing, evaluating and optimizing solar heating and cooling systems

    SciTech Connect

    Not Available

    1992-01-24

    The objective is to develop and test various integrated solar heating, cooling and domestic hot water systems, and to evaluate their performance. Systems composed of new, as well as previously tested, components are carefully integrated so that effects of new components on system performance can be clearly delineated. The SEAL-DOE program includes six tasks which have received funding for the 1991--92 fifteen-month period. These include: (1) a project employing isothermal operation of air and liquid solar space heating systems; (2) a project to build and test several generic solar water heaters; (3) a project that will evaluate advanced solar domestic hot water components and concepts and integrate them into solar domestic hot water systems; (4) a liquid desiccant cooling system development project; (5) a project that will perform system modeling and analysis work on solid desiccant cooling systems research; and (6) a management task. The objectives and progress in each task are described in this report.

  17. Performance study of a heat recovery desiccant cooling system

    NASA Astrophysics Data System (ADS)

    Sabek, Seifennasr; Ben Nasr, Kaouther; Chouikh, Ridha; Guizani, Amenallah

    2015-04-01

    The comparison between the experimental and theoretical simulations of a desiccant cooling system under various climatic conditions (outdoor temperature and relative humidity) on the system performance has been presented. The performance of the system is evaluated using Cooling Capacity (CC) parameter. The system under a typical summer day of hot and humid climate was tested. A remarkable decrease about 40-65% in the specific humidity and with a supply air temperature lower than 25°C of the proposed system was observed. The study is important and helpful to improve the effectiveness of this kind of liquid desiccant system in hot and humid places.

  18. Steam cooling system for a gas turbine

    DOEpatents

    Wilson, Ian David; Barb, Kevin Joseph; Li, Ming Cheng; Hyde, Susan Marie; Mashey, Thomas Charles; Wesorick, Ronald Richard; Glynn, Christopher Charles; Hemsworth, Martin C.

    2002-01-01

    The steam cooling circuit for a gas turbine includes a bore tube assembly supplying steam to circumferentially spaced radial tubes coupled to supply elbows for transitioning the radial steam flow in an axial direction along steam supply tubes adjacent the rim of the rotor. The supply tubes supply steam to circumferentially spaced manifold segments located on the aft side of the 1-2 spacer for supplying steam to the buckets of the first and second stages. Spent return steam from these buckets flows to a plurality of circumferentially spaced return manifold segments disposed on the forward face of the 1-2 spacer. Crossover tubes couple the steam supply from the steam supply manifold segments through the 1-2 spacer to the buckets of the first stage. Crossover tubes through the 1-2 spacer also return steam from the buckets of the second stage to the return manifold segments. Axially extending return tubes convey spent cooling steam from the return manifold segments to radial tubes via return elbows.

  19. Overview of Helium Cooled System Applications with RELAP at ENEA

    SciTech Connect

    Meloni, Paride; Casamirra, Maddalena

    2006-07-01

    Some years ago, within the framework of the study for the International Thermonuclear Experimental Reactor (ITER), ENEA assessed the RELAP5 code capability to simulate Helium cooled systems on the experimental data provided by the helium facility HEFUS3 (Brasimone, Italy). This activity allowed acquiring a certain experience on the limits and capabilities of the code that, in the following years, was used for a wide range of applications concerning transient and accident analysis of helium cooled systems. At first the paper summarizes the results of the assessment activity, then describes the accident analyses performed for the conceptual study of the Fusion Power Reactor with Helium-Cooled Pebble Bed Blanket (HCPBB) and the studies to support the safety design of the gas cooled Accelerator Driven System (ADS) concept. The paper concludes highlighting the RELAP adaptations to realize within the framework of the feasibility studies for a combined cycle concept of the Very High Temperature Reactor (VHTR). (authors)

  20. Solar heating and cooling system design and development

    NASA Technical Reports Server (NTRS)

    1979-01-01

    The design and development of marketable solar heating and cooling systems for single family and commercial applications is described. The delivery, installation, and monitoring of the prototype systems are discussed. Seven operational test sites are discussed in terms of system performance. Problems encountered with equipment and installation were usually due to lack of skills required for solar system installation.

  1. Active noise canceling system for mechanically cooled germanium radiation detectors

    SciTech Connect

    Nelson, Karl Einar; Burks, Morgan T

    2014-04-22

    A microphonics noise cancellation system and method for improving the energy resolution for mechanically cooled high-purity Germanium (HPGe) detector systems. A classical adaptive noise canceling digital processing system using an adaptive predictor is used in an MCA to attenuate the microphonics noise source making the system more deployable.

  2. Experimental study on resonant frequency of the thermoacoustic cooling system

    NASA Astrophysics Data System (ADS)

    Sakamoto, Shin-ichi; Hirano, Hiroyuki; Fujita, Takashi; Watanabe, Yoshiaki

    2006-05-01

    The purpose of our study is to construct a new cooling system applying the thermoacoustic effect. Stainless loop-tube is employed as our thermoacoustic cooling system and temperature decrease of 40 degrees C from the room temperature has been confirmed. In this paper, it is investigated that the relation between the viscosity boundary layer and the resonant frequency of the generated sound is investigated. Also, the sound pressure and temperature variation are observed with various total lengths of the loop-tube, with the view toward improvement in the cooling effect of the thermoacoustic cooling system. It was generally considered that the sound generated in the thermoacoustic cooling system is resonated with the tube length by 1 wavelength. However, when the total length of the loop-tube is over 2600 mm and inner pressure is 0.1 MPa, the resonant wavelength is 2. This is resulted from the influence of the viscosity boundary layer. It is found that the loop-tube decides the resonant frequency so that the thickness of the viscosity boundary layer is smaller than the stack channel radius. As a result, the resonant wavelength is 2 in a certain condition. The frequency is an important parameter for the thermoacoustic cooling system. From obtained results, one of the factors to select the frequency is found.

  3. Cooling Panel Optimization for the Active Cooling System of a Hypersonic Aircraft

    NASA Technical Reports Server (NTRS)

    Youn, B.; Mills, A. F.

    1995-01-01

    Optimization of cooling panels for an active cooling system of a hypersonic aircraft is explored. The flow passages are of rectangular cross section with one wall heated. An analytical fin-type model for incompressible flow in smooth-wall rectangular ducts with coupled wall conduction is proposed. Based on this model, the a flow rate of coolant to each design minimum mass flow rate or coolant for a single cooling panel is obtained by satisfying hydrodynamic, thermal, and Mach number constraints. Also, the sensitivity of the optimal mass flow rate of coolant to each design variable is investigated. In addition, numerical solutions for constant property flow in rectangular ducts, with one side rib-roughened and coupled wall conduction, are obtained using a k-epsilon and wall function turbulence model, these results are compared with predictions of the analytical model.

  4. Simulation of an active cooling system for photovoltaic modules

    NASA Astrophysics Data System (ADS)

    Abdelhakim, Lotfi

    2016-06-01

    Photovoltaic cells are devices that convert solar radiation directly into electricity. However, solar radiation increases the photovoltaic cells temperature [1] [2]. The temperature has an influence on the degradation of the cell efficiency and the lifetime of a PV cell. This work reports on a water cooling technique for photovoltaic panel, whereby the cooling system was placed at the front surface of the cells to dissipate excess heat away and to block unwanted radiation. By using water as a cooling medium for the photovoltaic solar cells, the overheating of closed panel is greatly reduced without prejudicing luminosity. The water also acts as a filter to remove a portion of solar spectrum in the infrared band but allows transmission of the visible spectrum most useful for the PV operation. To improve the cooling system efficiency and electrical efficiency, uniform flow rate among the cooling system is required to ensure uniform distribution of the operating temperature of the PV cells. The aims of this study are to develop a 3D thermal model to simulate the cooling and heat transfer in Photovoltaic panel and to recommend a cooling technique for the PV panel. The velocity, pressure and temperature distribution of the three-dimensional flow across the cooling block were determined using the commercial package, Fluent. The second objective of this work is to study the influence of the geometrical dimensions of the panel, water mass flow rate and water inlet temperature on the flow distribution and the solar panel temperature. The results obtained by the model are compared with experimental results from testing the prototype of the cooling device.

  5. Statistical mechanical and quantum mechanical modeling of condensed phase systems

    NASA Astrophysics Data System (ADS)

    Labrosse, Matthew R.

    systems. This was later expanded to include binary (Co/C, Co/O) and tertiary (Co/C/O) heterogeneous interactions. We have tested these parameters against additional DFT calculations not included in the training set. The parameter optimization has produced a force field capable of describing additional configurations with the same accuracy as those used in the fitting procedure. The optimized parameters have been used to predict the melting point and diffusion coefficients of condensed phase cobalt. Large-scale simulations of a Co2C phase nanoparticle show segregation on short time scales (less than 300 ps), with all C atoms forming chains and small graphene structures on the surface of a solid Co nanoparticle core. ReaxFF has also been used to show that diffusion of Co is more energetically favorable than oxygen through the interstitial sites of a cobalt oxide crystal. This is consistent with experimental observations that oxidized cobalt nanoparticle form hollow cobalt oxide nanospheres due to a faster Co diffusion rate through the oxide layer. These two binary applications demonstrate that ReaxFF is transferable to heterogeneous systems and is a computationally inexpensive means by which transition metal surface reactions can be explored.

  6. Characterization of N-Acylhomoserine Lactones Produced by Bacteria Isolated from Industrial Cooling Water Systems.

    PubMed

    Okutsu, Noriya; Morohoshi, Tomohiro; Xie, Xiaonan; Kato, Norihiro; Ikeda, Tsukasa

    2015-01-01

    The cooling water systems are used to remove heat generated in the various industries. Biofouling of the cooling water systems causes blocking of condenser pipes and the heat exchanger tubes. In many Gram-negative bacteria, N-acylhomoserine lactone (AHL) are used as quorum-sensing signal molecule and associated with biofilm formation. To investigate the relationship between quorum sensing and biofouling in the cooling water system, we isolated a total of 192 bacterial strains from the five cooling water systems, and screened for AHL production. Seven isolates stimulated AHL-mediated purple pigment production in AHL reporter strain Chromobacterium violaceum CV026 or VIR07. Based on their 16S rRNA gene sequences, AHL-producing isolates were assigned to Aeromonas hydrophila, Lysobacter sp., Methylobacterium oryzae, and Bosea massiliensis. To the best of our knowledge, B. massiliensis and Lysobacter sp. have not been reported as AHL-producing species in the previous researches. AHLs extracted from the culture supernatants of B. massiliensis and Lysobacter sp. were identified by liquid chromatography-mass spectrometry. AHLs produced by B. massiliensis were assigned as N-hexanoyl-L-homoserine lactone (C6-HSL), N-(3-oxohexanoyl)-L-homoserine lactone (3-oxo-C6-HSL), and N-(3-oxooctanoyl)-L-homoserine lactone (3-oxo-C8-HSL). AHLs produced by Lysobacter sp. were assigned as N-decanoyl-L-homoserine lactone (C10-HSL) and N-(3-oxodecanoyl)-L-homoserine lactone (3-oxo-C10-HSL). This is the first report of identification of AHLs produced by B. massiliensis and Lysobacter sp. isolated from the cooling water system. PMID:26729121

  7. Characterization of N-Acylhomoserine Lactones Produced by Bacteria Isolated from Industrial Cooling Water Systems

    PubMed Central

    Okutsu, Noriya; Morohoshi, Tomohiro; Xie, Xiaonan; Kato, Norihiro; Ikeda, Tsukasa

    2015-01-01

    The cooling water systems are used to remove heat generated in the various industries. Biofouling of the cooling water systems causes blocking of condenser pipes and the heat exchanger tubes. In many Gram-negative bacteria, N-acylhomoserine lactone (AHL) are used as quorum-sensing signal molecule and associated with biofilm formation. To investigate the relationship between quorum sensing and biofouling in the cooling water system, we isolated a total of 192 bacterial strains from the five cooling water systems, and screened for AHL production. Seven isolates stimulated AHL-mediated purple pigment production in AHL reporter strain Chromobacterium violaceum CV026 or VIR07. Based on their 16S rRNA gene sequences, AHL-producing isolates were assigned to Aeromonas hydrophila, Lysobacter sp., Methylobacterium oryzae, and Bosea massiliensis. To the best of our knowledge, B. massiliensis and Lysobacter sp. have not been reported as AHL-producing species in the previous researches. AHLs extracted from the culture supernatants of B. massiliensis and Lysobacter sp. were identified by liquid chromatography-mass spectrometry. AHLs produced by B. massiliensis were assigned as N-hexanoyl-l-homoserine lactone (C6-HSL), N-(3-oxohexanoyl)-l-homoserine lactone (3-oxo-C6-HSL), and N-(3-oxooctanoyl)-l-homoserine lactone (3-oxo-C8-HSL). AHLs produced by Lysobacter sp. were assigned as N-decanoyl-l-homoserine lactone (C10-HSL) and N-(3-oxodecanoyl)-l-homoserine lactone (3-oxo-C10-HSL). This is the first report of identification of AHLs produced by B. massiliensis and Lysobacter sp. isolated from the cooling water system. PMID:26729121

  8. Prototype solar heating and cooling systems

    NASA Technical Reports Server (NTRS)

    1978-01-01

    Eight prototype systems were developed. The systems are 3, 25, and 75-ton size units. The manufacture, test, installation, maintenance, problem resolution, and performance evaluation of the systems is described. Size activities for the various systems are included.

  9. Bose-Einstein Condensation of Strontium

    SciTech Connect

    Stellmer, Simon; Huang Bo; Grimm, Rudolf; Tey, Meng Khoon; Schreck, Florian

    2009-11-13

    We report on the attainment of Bose-Einstein condensation with ultracold strontium atoms. We use the {sup 84}Sr isotope, which has a low natural abundance but offers excellent scattering properties for evaporative cooling. Accumulation in a metastable state using a magnetic-trap, narrowline cooling, and straightforward evaporative cooling in an optical trap lead to pure condensates containing 1.5x10{sup 5} atoms. This puts {sup 84}Sr in a prime position for future experiments on quantum-degenerate gases involving atomic two-electron systems.

  10. Integrated numerical methods for hypersonic aircraft cooling systems analysis

    NASA Technical Reports Server (NTRS)

    Petley, Dennis H.; Jones, Stuart C.; Dziedzic, William M.

    1992-01-01

    Numerical methods have been developed for the analysis of hypersonic aircraft cooling systems. A general purpose finite difference thermal analysis code is used to determine areas which must be cooled. Complex cooling networks of series and parallel flow can be analyzed using a finite difference computer program. Both internal fluid flow and heat transfer are analyzed, because increased heat flow causes a decrease in the flow of the coolant. The steady state solution is a successive point iterative method. The transient analysis uses implicit forward-backward differencing. Several examples of the use of the program in studies of hypersonic aircraft and rockets are provided.

  11. NONWATER QUALITY IMPACTS OF CLOSED-CYCLE COOLING SYSTEMS AND THE INTERACTION OF STACK GAS AND COOLING TOWER PLUMES

    EPA Science Inventory

    The report gives results of a literature survey of the nonwater quality impacts of closed-cycle cooling systems. Following discussions of cooling tower and stack gas plumes, interactions of these plumes are considered. For cooling tower plumes, plume types, behavior, salt drift g...

  12. Investihation on the differentially cooled system

    SciTech Connect

    Kirloskar, C.S.; Chandorkar, S.B.; Rao, N.N.

    1984-01-01

    In order to clarify certain aspects of the combustion process in differentially cooled engines, a special engine was built in which the surface temperatures of the piston crown, cylinder liner and cyinder head bottom could be varied independently. A computer program to calculate the swirl and turbulence intensity in the combustion chamber was developed. Investigations showed that in order to improve the mixing process, the liner temperature should be kept low while the piston temperature may be increased only if the cylinder head temperature is kept low, and vice versa. A low coefficient of regression in the plotted results indicated that the flow parameters investigated were not the determining parameters but only one among many others which need further investigation. The present investigation however indicates that the high piston temperature found desirable earlier should preferably be combined with low cylinder head and liner temperatures.

  13. Evaluation of two cooling systems under a firefighter coverall.

    PubMed

    Teunissen, Lennart P J; Wang, Li-Chu; Chou, Shih-Nung; Huang, Chin-Hsien; Jou, Gwo-Tsuen; Daanen, Hein A M

    2014-11-01

    Firemen often suffer from heat strain. This study investigated two chest cooling systems for use under a firefighting suit. In nine male subjects, a vest with water soaked cooling pads and a vest with water perfused tubes were compared to a control condition. Subjects performed 30 min walking and 10 min recovery in hot conditions, while physiological and perceptual parameters were measured. No differences were observed in heart rate and rectal temperature, but scapular skin temperature and fluid loss were lower using the perfused vest. Thermal sensation was cooler for the perfused vest than for the other conditions, while the cool pad vest felt initially cooler than control. However, comfort and RPE scores were similar. We conclude that the cooling effect of both tested systems, mainly providing a (temporally) cooler thermal sensation, was limited and did not meet the expectations. PMID:24798511

  14. Use of Produced Water in Recirculated Cooling Systems at Power Generating Facilities

    SciTech Connect

    C. McGowin; M. DiFilippo; L. Weintraub

    2006-06-30

    Tree ring studies indicate that, for the greater part of the last three decades, New Mexico has been relatively 'wet' compared to the long-term historical norm. However, during the last several years, New Mexico has experienced a severe drought. Some researchers are predicting a return of very dry weather over the next 30 to 40 years. Concern over the drought has spurred interest in evaluating the use of otherwise unusable saline waters to supplement current fresh water supplies for power plant operation and cooling and other uses. The U.S. Department of Energy's National Energy Technology Laboratory sponsored three related assessments of water supplies in the San Juan Basin area of the four-corner intersection of Utah, Colorado, Arizona, and New Mexico. These were (1) an assessment of using water produced with oil and gas as a supplemental supply for the San Juan Generating Station (SJGS); (2) a field evaluation of the wet-surface air cooling (WSAC) system at SJGS; and (3) the development of a ZeroNet systems analysis module and an application of the Watershed Risk Management Framework (WARMF) to evaluate a range of water shortage management plans. The study of the possible use of produced water at SJGS showed that produce water must be treated to justify its use in any reasonable quantity at SJGS. The study identified produced water volume and quality, the infrastructure needed to deliver it to SJGS, treatment requirements, and delivery and treatment economics. A number of produced water treatment alternatives that use off-the-shelf technology were evaluated along with the equipment needed for water treatment at SJGS. Wet surface air-cooling (WSAC) technology was tested at the San Juan Generating Station (SJGS) to determine its capacity to cool power plant circulating water using degraded water. WSAC is a commercial cooling technology and has been used for many years to cool and/or condense process fluids. The purpose of the pilot test was to determine if WSAC

  15. Desiccant dehumidification and cooling systems assessment and analysis

    SciTech Connect

    Collier, R.K. Jr.

    1997-09-01

    The objective of this report is to provide a preliminary analysis of the principles, sensitivities, and potential for national energy savings of desiccant cooling and dehumidification systems. The report is divided into four sections. Section I deals with the maximum theoretical performance of ideal desiccant cooling systems. Section II looks at the performance effects of non-ideal behavior of system components. Section III examines the effects of outdoor air properties on desiccant cooling system performance. Section IV analyzes the applicability of desiccant cooling systems to reduce primary energy requirements for providing space conditioning in buildings. A basic desiccation process performs no useful work (cooling). That is, a desiccant material drying air is close to an isenthalpic process. Latent energy is merely converted to sensible energy. Only when heat exchange is applied to the desiccated air is any cooling accomplished. This characteristic is generic to all desiccant cycles and critical to understanding their operation. The analyses of Section I show that desiccant cooling cycles can theoretically achieve extremely high thermal CoP`s (>2). The general conclusion from Section II is that ventilation air processing is the most viable application for the solid desiccant equipment analyzed. The results from the seasonal simulations performed in Section III indicate that, generally, the seasonal performance of the desiccant system does not change significantly from that predicted for outdoor conditions. Results from Section IV show that all of the candidate desiccant systems can save energy relative to standard vapor-compression systems. The largest energy savings are achieved by the enthalpy exchange devise.

  16. System and method for cooling a combustion gas charge

    DOEpatents

    Massey, Mary Cecelia; Boberg, Thomas Earl

    2010-05-25

    The present invention relates to a system and method for cooling a combustion gas charge prior. The combustion gas charge may include compressed intake air, exhaust gas, or a mixture thereof. An evaporator is provided that may then receive a relatively high temperature combustion gas charge and discharge at a relatively lower temperature. The evaporator may be configured to operate with refrigeration cycle components and/or to receive a fluid below atmospheric pressure as the phase-change cooling medium.

  17. Closed-loop air cooling system for a turbine engine

    DOEpatents

    North, William Edward

    2000-01-01

    Method and apparatus are disclosed for providing a closed-loop air cooling system for a turbine engine. The method and apparatus provide for bleeding pressurized air from a gas turbine engine compressor for use in cooling the turbine components. The compressed air is cascaded through the various stages of the turbine. At each stage a portion of the compressed air is returned to the compressor where useful work is recovered.

  18. Electron beam size measurements in the Fermilab Electron Cooling System

    SciTech Connect

    Kroc, T.K.; Burov, A.V.; Bolshakov, T.B.; Shemyakin, A.; Seletskiy, S.M.; /Rochester U.

    2005-09-01

    The Fermilab Electron Cooling Project requires a straight trajectory and constant beam size to provide maximum cooling of the antiprotons in the Recycler. A measurement system was developed using movable apertures and steering bumps to measure the beam size in a 20m long, nearly continuous, solenoid. This paper will focus on results of these measurements of the beam size and the difficulties in making those measurements.

  19. Electron Beam Size Measurements in the Fermilab Electron Cooling System

    SciTech Connect

    Kroc, T. K.; Burov, A. V.; Bolshakov, T. B.; Shemyakin, A.; Seletskiy, S. M.

    2006-03-20

    The Fermilab Electron Cooling Project requires a straight trajectory and constant beam size to provide maximum cooling of the antiprotons in the Recycler. A measurement system was developed using movable apertures and steering bumps to measure the beam size in a 20m long, nearly continuous, solenoid. This paper will focus on results of these measurements of the beam size and the difficulties in making those measurements.

  20. Effect of input power on cooling property of a thermoacoustic cooling system with diameter-expanded prime movers

    NASA Astrophysics Data System (ADS)

    Ueno, So; Sakamoto, Shin-ichi; Orino, Yuichiro; Wada, Takahiro; Inui, Yoshitaka; Watanabe, Yoshiaki

    2016-07-01

    We studied a thermoacoustic cooling system driven at low temperatures to make practical use of the system. Aiming to reduce the driving temperature of the thermoacoustic system, we developed a loop-tube-type thermoacoustic system with diameter-expanded two-stage prime movers, i.e., a heat-to-sound transducer. The system drove at 67 °C. Additionally, we developed a prototype for a thermoacoustic cooling system with a diameter-expanded two-stage prime mover. In the experiment, the cooling point temperature was decreased by 4.4 °C from room temperature, i.e., 20 °C. To improve the cooling performance of the prototype thermoacoustic cooling system, we experimentally investigated the effect of increasing the input power on the cooling performance.

  1. A spacecraft cooling system for a charged coupled device

    NASA Technical Reports Server (NTRS)

    Walker, Mary S.; Tulkoff, Philip

    1986-01-01

    This paper describes the thermal analysis, design, and testing of a dedicated cooling system for a Spartan spacecraft payload. A simple reliable design that requires minimum power consumption and minimum weight was developed. The payload has a CCD detector that must be maintained at a temperature of approximately -40 C or colder. The cooling system consists of a fin radiator, dual redundant heat pipes, and a thermal electric device (TED). The system was analytically modeled through the use of the Simplified Shuttle Payload Thermal Analyzer (SSPTA) computer program. A thermal test of the system simulating flight conditions was conducted to correlate the computer model and verify performance specifications.

  2. Solar heating and cooling system design and development

    NASA Technical Reports Server (NTRS)

    1978-01-01

    The progress of the program during the sixth program quarter is reported. The program calls for the development and delivery of eight prototype solar heating and cooling systems for installation and operational test. The William O'Brien single-family heating system was installed and is operational. The New Castle single-family heating residence is under construction. The Kansas University (KU) system is in the final design stages. The 25 ton cooling subsystem for KU is the debugging stage. Pressure drops that were greater than anticipated were encountered. The 3 ton simulation work is being finalized and the design parameters for the Rankine system were determined from simulation output.

  3. Inhibitor analysis for a solar heating and cooling system

    NASA Technical Reports Server (NTRS)

    Tabony, J. H.

    1977-01-01

    A study of potential corrosion inhibitors for the NASA solar heating and cooling system which uses aluminum solar panels is provided. Research consisted of testing using a dynamic corrosion system, along with an economic analysis of proposed corrosion inhibitors. Very good progress was made in finding a suitable inhibitor for the system.

  4. Automatic pre-cooling system for large infrared instruments

    NASA Astrophysics Data System (ADS)

    Omata, Koji; Nishimura, Tetsuo; Colley, Stephen; Cook, David; Gorman, William; Magrath, Barney; Ramos, Lucio; Kleinman, Scot; Tokoku, Chihiro; Konishi, Masahiro; Yoshikawa, Tomohiro; Tanaka, Ichi; Suzuki, Ryuji

    2008-07-01

    An infrared instrument used for observation has to keep the detector and optical components in a very cold environment during operation. However, because of maintenance, upgrades, and other routine work, there are situations that require the instrument to be warmed-up and then cooled-down again. At Subaru Observatory, our MOIRCS infrared instrument has required warm-up and cool-down several times a year for routine maintenance and filter replacement. The MOIRCS instrument has a large heat capacity and cool-down using only the closed cycle cooler is impractical due to the huge amount of time it would require. To address this problem Subaru engineers have created a mechanism to allow PRE-COOLING of the instrument via liquid nitrogen - allowing for a much faster pre-cool process. Even with liquid nitrogen, the pre-cool process requires 10 tanks and almost a week of continual monitoring in order to reach the desired target temperature. It is very difficult to work for such a long period of time at the oxygen starved summit of Mauna Kea (4205 meters),and issues of man-power and scheduling conflicts only add to the problems. To address these concerns Subaru developed an automated pre-cooling system which works continuously and remotely at the summit. The strategy was to have basic functionality for pre-cooling and user friendly interface. i.e. (1) Continuous cooling until the target temperature is reached by automated liquid nitrogen tank exchanges and precision temperature control by automated changes to the liquid nitrogen flow. (2) Remote monitoring and control of all parameter setting by Web browser as user interface (UI). The goal of the Subaru pre-cooling system was to make it both inexpensive and quick to implement by using existing technologies. The original goal (to cut down on labor and precision temperature control) has been attained through several pre-cooling and software/hardware modification cycles. We will report on the progress and status of our pre-cooling

  5. ATP technology, a tool for monitoring microbes in cooling systems

    SciTech Connect

    Czechowski, M.H.

    1996-11-01

    Rapid and accurate measurement of microbes is important for controlling the formation of troublesome microbial slimes in cooling water systems. One method for accomplishing this involves the measurement of Adenosine Triphosphate (ATP), a compound used to store and transfer energy in microbial cells. Cellular ATP is determined by chemically rupturing cells, which releases ATP that reacts with a luciferase reagent (the firefly enzyme). This reaction produces light which can be detected by a sensitive luminometer/photometer. The amount of light produced is proportional to the amount of ATP in the cell. A quantitative indication of biological activity is obtained in minutes, compared to traditional plating methods which often require days of incubation. The use of ATP for microbial detection has been available for many years; however, industrial usage was limited because the ATP procedure was neither easy to perform nor was it cost effective. Recently, advances in instrument technology, extractant chemistry and enzyme stability have made ATP detection more practical and less expensive. ATP technology can be used for determining microbial content in cooling water systems, predicting biocide effectiveness, and monitoring efficacy of biocides in cooling systems. A good correlation (0.85) was found between microbial ATP values and bacterial Colony Forming Units (CFU) in cooling waters. ATP technology was used to determine the effectiveness of different concentrations of a biocide in a test system within 1 hour after biocide addition. Test results accurately predicted the biocide efficacy in the cooling tower. Effectiveness of other biocides in cooling systems were monitored with results being obtained within minutes after sampling. These findings indicate the potential for ATP technology to be an effective tool in monitoring microbes in cooling water systems.

  6. Pulse tube cryocooler SQUID cooling system involving an infrared temperature controller cooled by a cryocooler

    NASA Astrophysics Data System (ADS)

    Tanaka, S.; Iwao, S.; Hatsukade, Y.

    2005-10-01

    We propose a pulse tube cryocooler SQUID cooling system, which temperature was controlled by an infrared source. A high-Tc SQUID magnetometer was mounted and cooled by a coaxial pulse tube cryocooler. A light from a halogen lamp was guided by a quartz flexible bundle fiber and was introduced to the cold head. The output power of the lamp was controlled by a temperature controller in accordance with the cold stage temperature. As a result, the flux noise of the SQUID output was not changed in the range of 1-1000 Hz regardless of the lamp power. The temperature could be controlled at 77 K with accuracy of ±0.03 K for long time duration more than 2 h. This demonstrated that the system can be applied to any applications such as NDE systems.

  7. Use of a temperature-initiated passive cooling system (TIPACS) for the modular high-temperature gas-cooled reactor cavity cooling system (RCCS)

    SciTech Connect

    Forsberg, C.W.; Conklin, J.; Reich, W.J.

    1994-04-01

    A new type of passive cooling system has been invented (Forsberg 1993): the Temperature-Initiated Passive Cooling System (TIPACS). The characteristics of the TIPACS potentially match requirements for an improved reactor-cavity-cooling system (RCCS) for the modular high-temperature gas-cooled reactor (MHTGR). This report is an initial evaluation of the TIPACS for the MHTGR with a Rankines (steam) power conversion cycle. Limited evaluations were made of applying the TIPACS to MHTGRs with reactor pressure vessel temperatures up to 450 C. These temperatures may occur in designs of Brayton cycle (gas turbine) and process heat MHTGRs. The report is structured as follows. Section 2 describes the containment cooling issues associated with the MHTGR and the requirements for such a cooling system. Section 3 describes TIPACS in nonmathematical terms. Section 4 describes TIPACS`s heat-removal capabilities. Section 5 analyzes the operation of the temperature-control mechanism that determines under what conditions the TIPACS rejects heat to the environment. Section 6 addresses other design and operational issues. Section 7 identifies uncertainties, and Section 8 provides conclusions. The appendixes provide the detailed data and models used in the analysis.

  8. A multiscale thermo-fluid computational model for a two-phase cooling system

    NASA Astrophysics Data System (ADS)

    Sacco, Riccardo; Carichino, Lucia; de Falco, Carlo; Verri, Maurizio; Agostini, Francesco; Gradinger, Thomas

    2014-12-01

    In this paper, we describe a mathematical model and a numerical simulation method for the condenser component of a novel two-phase thermosyphon cooling system for power electronics applications. The condenser consists of a set of roll-bonded vertically mounted fins among which air flows by either natural or forced convection. In order to deepen the understanding of the mechanisms that determine the performance of the condenser and to facilitate the further optimization of its industrial design, a multiscale approach is developed to reduce as much as possible the complexity of the simulation code while maintaining reasonable predictive accuracy. To this end, heat diffusion in the fins and its convective transport in air are modeled as 2D processes while the flow of the two-phase coolant within the fins is modeled as a 1D network of pipes. For the numerical solution of the resulting equations, a Dual Mixed-Finite Volume scheme with Exponential Fitting stabilization is used for 2D heat diffusion and convection while a Primal Mixed Finite Element discretization method with upwind stabilization is used for the 1D coolant flow. The mathematical model and the numerical method are validated through extensive simulations of realistic device structures which prove to be in excellent agreement with available experimental data.

  9. Replacement inhibitors for tank farm cooling coil systems

    SciTech Connect

    Hsu, T.C.

    1995-03-23

    Sodium chromate has been an effective corrosion inhibitor for the cooling coil systems in Savannah River Site (SRS) waste tanks for over 40 years. Due to their age and operating history, cooling coils occasionally fail allowing chromate water to leak into the environment. When the leaks spill 10 lbs. or more of sodium chromate over a 24-hr period, the leak incidents are classified as Unusual Occurrences (UO) per CERCLA (Comprehensive Environmental Response, Compensation and Liability Act). The cost of reporting and cleaning up chromate spills prompted High Level Waste Engineering (HLWE) to initiate a study to investigate alternative tank cooling water inhibitor systems and the associated cost of replacement. Several inhibitor systems were investigated as potential alternatives to sodium chromate. All would have a lesser regulatory impact, if a spill occurred. However, the conversion cost is estimated to be $8.5 million over a period of 8 to 12 months to convert all 5 cooling systems. Although each of the alternative inhibitors examined is effective in preventing corrosion, there is no inhibitor identified that is as effective as chromate. Assuming 3 major leaks a year (the average over the past several years), the cost of maintaining the existing inhibitor was estimated at $0.5 million per year. Since there is no economic or regulatory incentive to replace the sodium chromate with an alternate inhibitor, HLWE recommends that sodium chromate continue to be used as the inhibitor for the waste tank cooling systems.

  10. Development of a higher power cooling system for lithium targets.

    PubMed

    Phoenix, B; Green, S; Scott, M C; Bennett, J R J; Edgecock, T R

    2015-12-01

    The accelerator based Boron Neutron Capture Therapy beam at the University of Birmingham is based around a solid thick lithium target cooled by heavy water. Significant upgrades to Birmingham's Dynamitron accelerator are planned prior to commencing a clinical trial. These upgrades will result in an increase in maximum achievable beam current to at least 3 mA. Various upgrades to the target cooling system to cope with this increased power have been investigated. Tests of a phase change coolant known as "binary ice" have been carried out using an induction heater to provide a comparable power input to the Dynamitron beam. The experimental data shows no improvement over chilled water in the submerged jet system, with both systems exhibiting the same heat input to target temperature relation for a given flow rate. The relationship between the cooling circuit pumping rate and the target temperature in the submerged jet system has also been tested. PMID:26254970

  11. Experimental investigation of condensation predictions for dust-enriched systems

    NASA Astrophysics Data System (ADS)

    Ustunisik, Gokce; Ebel, Denton S.; Walker, David; Boesenberg, Joseph S.

    2014-10-01

    Condensation models describe the equilibrium distribution of elements between coexisting phases (mineral solid solutions, silicate liquid, and vapor) in a closed chemical system, where the vapor phase is always present, using equations of state of the phases involved at a fixed total pressure (<1 bar) and temperature (T). The VAPORS code uses a CaO-MgO-Al2O3-SiO2 (CMAS) liquid model at T above the stability field of olivine, and the MELTS thermodynamics algorithm at lower T. Quenched high-T crystal + liquid assemblages are preserved in meteorites as Type B Ca-, Al-rich inclusions (CAIs), and olivine-rich ferromagnesian chondrules. Experimental tests of compositional regions within 100 K of the predicted T of olivine stability may clarify the nature of the phases present, the phase boundaries, and the partition of trace elements among these phases. Twenty-three Pt-loop equilibrium experiments in seven phase fields on twelve bulk compositions at specific T and dust enrichment factors tested the predicted stability fields of forsteritic olivine (Mg2SiO4), enstatite (MgSiO3), Cr-bearing spinel (MgAl2O4), perovskite (CaTiO3), melilite (Ca2Al2SiO7-Ca2Mg2Si2O7) and/or grossite (CaAl4O7) crystallizing from liquid. Experimental results for forsterite, enstatite, and grossite are in very good agreement with predictions, both in chemistry and phase abundances. On the other hand the stability of spinel with olivine, and stability of perovskite and gehlenite are quite different from predictions. Perovskite is absent in all experiments. Even at low oxygen fugacity (IW-3.4), the most TiO2-rich experiments do not crystallize Al-, Ti-bearing calcic pyroxene. The stability of spinel and olivine together is limited to a smaller phase field than is predicted. The melilite stability field is much larger than predicted, indicating a deficiency of current liquid or melilite activity models. In that respect, these experiments contribute to improving the data for calibrating thermodynamic

  12. Wireless Sensor Network-Based Greenhouse Environment Monitoring and Automatic Control System for Dew Condensation Prevention

    PubMed Central

    Park, Dae-Heon; Park, Jang-Woo

    2011-01-01

    Dew condensation on the leaf surface of greenhouse crops can promote diseases caused by fungus and bacteria, affecting the growth of the crops. In this paper, we present a WSN (Wireless Sensor Network)-based automatic monitoring system to prevent dew condensation in a greenhouse environment. The system is composed of sensor nodes for collecting data, base nodes for processing collected data, relay nodes for driving devices for adjusting the environment inside greenhouse and an environment server for data storage and processing. Using the Barenbrug formula for calculating the dew point on the leaves, this system is realized to prevent dew condensation phenomena on the crop’s surface acting as an important element for prevention of diseases infections. We also constructed a physical model resembling the typical greenhouse in order to verify the performance of our system with regard to dew condensation control. PMID:22163813

  13. Bose-Einstein condensation mechanism in economic system

    NASA Astrophysics Data System (ADS)

    Xu, Jianping

    2015-06-01

    This paper starts from modifying the kinetic exchange model and ends with making a parallel between economic crisis and the Bose-Einstein condensation. By introducing a parameter δ, we incorporate the time influence into the Bose-Einstein statistics. And δ is found to represent the technology level in an economy. δ's growth in time enlarges the rich and poor gap and induces economic crisis in free market despite the fact that average living standard is raised. Then we find the “δ-Te-Entropy” dilemma which features a strong implication of the second law of thermodynamics. The dilemma means when an economy is isolated the entropy grows and synergetically Te and δ grow inducing the Bose-Einstein condensation, i.e., economic crisis while for open economy the dilemma breaks. Then we raise the question: What would happen if the world economy as a whole became isolated with ultimately omnibearing globalization?

  14. Cooling system optimization analysis for hot forming processes

    NASA Astrophysics Data System (ADS)

    Ghoo, Bonyoung; Umezu, Yasuyoshi; Watanabe, Yuko

    2013-12-01

    Hot forming technology was developed to produce automotive panels having ultra-high tensile stress over 1500MPa. The elevated temperature corresponds with decreased flow stress and increased ductility. Furthermore, hot forming products have almost zero springback amounts. This advanced forming technology accelerates the needs for numerical simulations coupling with thermal-mechanical formulations. In the present study, 3-dimensional finite element analyses for hot forming processes are conducted using JSTAMP/NV and LS-DYNA considering cooling system. Special attention is paid to the optimization of cooling system using thermo-mechanical finite element analysis through the influence of various cooling parameters. The presented work shows an adequate cooling system functions and microstructural phase transformation material model together with a proper set of numerical parameters can give both efficient and accurate design insight in hot forming manufacturing process. JSTAMP/NV and LS-DYNA can become a robust combination set for complex hot forming analysis which needs thermo-mechanical and microstructural material modeling and various process modeling. The use of the new JSTAMP/NV function for multishot manufacturing process is shown good capabilities in cooling system evaluation. And the use of the advanced LS-DYNA microstructural phase transformation model is shown good evaluation results in martensite amount and Vickers hardness after quenching.

  15. Reactor with natural convection backup cooling system

    SciTech Connect

    Koutz, S.L.; Cavallaro, L.; Kapich, D.D.

    1988-07-26

    A nuclear reactor is described comprising: a closed vessel containing a pool of secondary coolant; a reactor core located within the pool; an inlet conduit system for directing primary coolant to the lower end of the core; pumping means for effecting flow of the primary coolant into the inlet conduit system; an outlet conduit system located above the core for receiving coolant from the upper end of the core and carrying it to an exterior outlet pipe; and pressure reduction means for reducing fluid pressure in the inlet conduit system adjacent all of the one or more opening therein by locally increasing fluid velocity adjacent all of the one or more openings.

  16. Thermal hydraulic modeling of integrated cooling water systems

    SciTech Connect

    Niyogi, K.K.; Rathi, J.S.; Phan, T.Q.; Chaudhary, A.

    1994-12-31

    Thermal hydraulic modeling of cooling water systems has been extended to multiple system configurations with heat exchangers as interface components between systems. The computer program PC-TRAX has been used as the basic tool for the system simulation. Additional heat exchanger modules have been incorporated to accurately predict the thermal performance of systems for the design as well as off-design conditions. The modeling accommodates time-dependent changes in conditions, temperature and pressure controllers, and detailed physical parameters of the heat exchangers. The modeling has been illustrated with examples from actual plant systems. An integrated system consisting of Spent Fuel Pool, Primary Component Cooling Water, and Service Water System has been successfully modeled to predict their performance under normal operations and emergency conditions. System configurations are changed from the base model by using a command module.

  17. Prototype solar heating and cooling systems including potable hot water

    NASA Technical Reports Server (NTRS)

    1978-01-01

    Progress is reviewed in the development, delivery, and support of two prototype solar heating and cooling systems including potable hot water. The system consisted of the following subsystems: collector, auxiliary heating, potable hot water, storage, control, transport, and government-furnished site data acquisition.

  18. Problems encountered in solar heating and cooling systems

    NASA Technical Reports Server (NTRS)

    Cash, M.

    1979-01-01

    Report discussing various experiences of workers at Marshall Space Flight Center in developing solar heating and cooling systems is presented. Presents compilation of problems and their resolutions which can assist designers of solar-energy systems and prevent repetition of errors.

  19. Preliminary design study of astronomical detector cooling system

    NASA Technical Reports Server (NTRS)

    Norman, R. H.

    1976-01-01

    The preliminary design of an astronomical detector cooling system for possible use in the NASA C-141 Airborne Infrared Observatory is presented. The system consists of the following elements: supercritical helium tank, Joule-Thomson supply gas conditioner, Joule-Thomson expander (JTX), optical cavity dewar, optical cavity temperature controller, adjustable J-T discharge gas pressure controller, and vacuum pump.

  20. Prototype solar heating and cooling systems including potable hot water

    NASA Technical Reports Server (NTRS)

    1978-01-01

    These combined quarterly reports summarize the activities from November 1977 through September 1978, and over the progress made in the development, delivery and support of two prototype solar heating and cooling systems including potable hot water. The system consists of the following subsystems: solar collector, auxiliary heating, potable hot water, storage, control, transport, and government-furnished site data acquisition.

  1. A System for Cooling inside a Glove Box

    ERIC Educational Resources Information Center

    Sanz, Martial

    2010-01-01

    An easy, efficient, reliable, and low-cost method of constructing a cooling system using a simple circulating pump is described. The system is employed in conjunction with an inert atmosphere glove box to achieve the synthesis of air- and moisture-sensitive compounds inside the glove box at controlled, low temperatures without contaminating the…

  2. An assessment of dehumidifier geometries for desiccant cooling systems

    NASA Astrophysics Data System (ADS)

    Barlow, R. S.

    1983-06-01

    Dehumidifier geometries for open-cycle, solid desiccant cooling systems are assessed in order to identify those configurations which have the greatest potential of achieving performance levels that will make desiccant cooling systems economically competitive with conventional vapor-compression systems. Five dehumidifier designs are described and compared quantitatively. Compared characteristics were then related to the requirements of solar cooling application. The wound-ribbon dehumidifer design showed the highest ratio of Stanton number to friction factor and the lowest solid-side resistance to mass transfer of any geometry tested. Because of the high potential of the wound-ribbon configuration, it is recommended that further research be carried out to fully characterized this type of dehumidifier.

  3. Traveling Wave RF Systems for Helical Cooling Channels

    SciTech Connect

    Yonehara, K.; Lunin, A.; Moretti, A.; Popovic, M.; Romanov, G.; Neubauer, M.; Johnson, R.P.; Thorndahl, L.; /CERN

    2009-05-01

    The great advantage of the helical ionization cooling channel (HCC) is its compact structure that enables the fast cooling of muon beam 6-dimensional phase space. This compact aspect requires a high average RF gradient, with few places that do not have cavities. Also, the muon beam is diffuse and requires an RF system with large transverse and longitudinal acceptance. A traveling wave system can address these requirements. First, the number of RF power coupling ports can be significantly reduced compared with our previous pillbox concept. Secondly, by adding a nose on the cell iris, the presence of thin metal foils traversed by the muons can possibly be avoided. We show simulations of the cooling performance of a traveling wave RF system in a HCC, including cavity geometries with inter-cell RF power couplers needed for power propagation.

  4. Thermotunneling Based Cooling Systems for High Efficiency Buildings

    SciTech Connect

    Aimi, Marco; Arik, Mehmet; Bray, James; Gorczyca, Thomas; Michael, Darryl; Weaver, Stan

    2007-09-30

    GE Global Research's overall objective was to develop a novel thermotunneling-cooling device. The end use for these devices is the replacement of vapor cycle compression (VCC) units in residential and commercial cooling and refrigeration systems. Thermotunneling devices offer many advantages over vapor cycle compression cooling units. These include quiet, reliable, non-moving parts operation without refrigerant gases. Additionally theoretical calculations suggest that the efficiency of thermotunneling devices can be 1.5-2x that of VCC units. Given these attributes it can be seen that thermotunneling devices have the potential for dramatic energy savings and are environmentally friendly. A thermotunneling device consists of two low work function electrodes separated by a sub 10 nanometer-sized gap. Cooling by thermotunneling refers to the transport of hot electrons across the gap, from the object to be cooled (cathode) to the heat rejection electrode (anode), by an applied potential. GE Global Research's goal was to model, design, fabricate devices and demonstrate cooling base on the thermotunneling technology.

  5. Improved plant performance through evaporative steam condensing

    SciTech Connect

    Hutton, D.

    1998-07-01

    Combining an open cooling tower and a steam condenser into one common unit is a proven technology with many advantages in power generation application, including reduced first cost of equipment, reduced parasitic energy consumption, simplified design, reduced maintenance, and simplified water treatment, Performance of the steam turbine benefits from the direct approach to wet bulb temperature, and operating flexibility and reliability improve compared to a system with a cooling tower and surface condenser. System comparisons and case histories will be presented to substantiate improved systems economies.

  6. Systems Evaluation at the Cool Energy House

    SciTech Connect

    J. Williamson and S. Puttagunta

    2013-09-01

    Steven Winter Associates, Inc. (SWA) monitored several advanced mechanical systems within a 2012 deep energy retrofitted home in the small Orlando suburb of Windermere, FL. This report provides performance results of one of the home's heat pump water heaters (HPWH) and the whole-house dehumidifier (WHD) over a six month period. In addition to assessing the energy performance of these systems, this study sought to quantify potential comfort improvements over traditional systems. This information is applicable to researchers, designers, plumbers, and HVAC contractors. Though builders and homeowners can find useful information within this report, the corresponding case studies are a likely better reference for this audience.

  7. Systems Evaluation at the Cool Energy House

    SciTech Connect

    Williamson, J.; Puttagunta, S.

    2013-09-01

    Steven Winter Associates, Inc. (SWA) monitored several advanced mechanical systems within a 2012 deep energy retrofitted home in the small Orlando suburb of Windermere, FL. This report provides performance results of one of the home's heat pump water heaters (HPWH) and the whole-house dehumidifier (WHD) over a six month period. In addition to assessing the energy performance of these systems,this study sought to quantify potential comfort improvements over traditional systems. This information is applicable to researchers, designers, plumbers, and HVAC contractors. Though builders and homeowners can find useful information within this report, the corresponding case studies are a likely better reference for this audience.

  8. The development of a solar residential heating and cooling system

    NASA Technical Reports Server (NTRS)

    1975-01-01

    The MSFC solar heating and cooling facility was assembled to demonstrate the engineering feasibility of utilizing solar energy for heating and cooling buildings, to provide an engineering evaluation of the total system and the key subsystems, and to investigate areas of possible improvement in design and efficiency. The basic solar heating and cooling system utilizes a flat plate solar energy collector, a large water tank for thermal energy storage, heat exchangers for space heating, and an absorption cycle air conditioner for space cooling. A complete description of all systems is given. Development activities for this test system included assembly, checkout, operation, modification, and data analysis, all of which are discussed. Selected data analyses for the first 15 weeks of testing are included, findings associated with energy storage and the energy storage system are outlined, and conclusions resulting from test findings are provided. An evaluation of the data for summer operation indicates that the current system is capable of supplying an average of 50 percent of the thermal energy required to drive the air conditioner. Preliminary evaluation of data collected for operation in the heating mode during the winter indicates that nearly 100 percent of the thermal energy required for heating can be supplied by the system.

  9. Cavity Cooling of A Mechanical Resonator in Amorphous Systems

    NASA Astrophysics Data System (ADS)

    Tian, Lin

    2011-03-01

    The quantum backaction force generated by a cavity coupled with a mechanical resonator can be exploited to achieve sideband cooling of the mechanical mode. By applying a red-detuned driving, the quantum ground state of the mechanical mode can be reached in the resolved-sideband regime, which has recently be demonstrated in experiments. However, in many of these materials, surface defects or adsorbates can couple with the mechanical mode and impair the cavity cooling. These defects can be treated as quantum two-level system (TLS). The mechanical vibration changes the local strain tensor and generates coupling with the TLS via the deformation potential. In this work, we study the cavity cooling of the mechanical mode in the presence of a TLS. By applying the adiabatic elimination technique widely used in quantum optics, we derive the cooling master equation for the resonator-TLS system in the eigenbasis of this system. Our results show that the stationary phonon number depends non- monotonically on the energy of the TLS. We also show that the cooling depends strongly on the decoherence rate of the TLS. This work is supported by the DARPA/MTO ORCHID program through AFOSR, NSF-DMR-0956064, NSF-CCF-0916303, and NSF COINS program.

  10. AUTOMOTIVE DIESEL MAINTENANCE 1. UNIT IV, MAINTAINING THE COOLING SYSTEM--DETROIT DIESEL ENGINES.

    ERIC Educational Resources Information Center

    Human Engineering Inst., Cleveland, OH.

    THIS MODULE OF A 30-MODULE COURSE IS DESIGNED TO DEVELOP AN UNDERSTANDING OF THE OPERATION AND MAINTENANCE OF THE DIESEL ENGINE COOLING SYSTEM. TOPICS ARE PURPOSE OF THE COOLING SYSTEM, CARE MAINTENANCE OF THE COOLING SYSTEM, COOLING SYSTEM COMPONENTS, AND TROUBLESHOOTING TIPS. THE MODULE CONSISTS OF A SELF-INSTRUCTIONAL BRANCH PROGRAMED TRAINING…

  11. Radiation detector system having heat pipe based cooling

    DOEpatents

    Iwanczyk, Jan S.; Saveliev, Valeri D.; Barkan, Shaul

    2006-10-31

    A radiation detector system having a heat pipe based cooling. The radiation detector system includes a radiation detector thermally coupled to a thermo electric cooler (TEC). The TEC cools down the radiation detector, whereby heat is generated by the TEC. A heat removal device dissipates the heat generated by the TEC to surrounding environment. A heat pipe has a first end thermally coupled to the TEC to receive the heat generated by the TEC, and a second end thermally coupled to the heat removal device. The heat pipe transfers the heat generated by the TEC from the first end to the second end to be removed by the heat removal device.

  12. Better Duct Systems for Home Heating and Cooling

    SciTech Connect

    Not Available

    2004-11-01

    Duct systems used in forced-air space-conditioning systems are a vital element in home energy efficiency. How well a system works makes a big difference in the cost and the effectiveness of heating and cooling a home. At the same time, a duct system that is poorly designed or maintained can have a detrimental effect on the health of the people who live in the house, through the unintended distribution of indoor air pollution.

  13. Wind turbine generators having wind assisted cooling systems and cooling methods

    DOEpatents

    Bagepalli, Bharat; Barnes, Gary R.; Gadre, Aniruddha D.; Jansen, Patrick L.; Bouchard, Jr., Charles G.; Jarczynski, Emil D.; Garg, Jivtesh

    2008-09-23

    A wind generator includes: a nacelle; a hub carried by the nacelle and including at least a pair of wind turbine blades; and an electricity producing generator including a stator and a rotor carried by the nacelle. The rotor is connected to the hub and rotatable in response to wind acting on the blades to rotate the rotor relative to the stator to generate electricity. A cooling system is carried by the nacelle and includes at least one ambient air inlet port opening through a surface of the nacelle downstream of the hub and blades, and a duct for flowing air from the inlet port in a generally upstream direction toward the hub and in cooling relation to the stator.

  14. EVA space suit Evaporative Cooling/Heating Glove System (ECHGS)

    NASA Technical Reports Server (NTRS)

    Coss, F. A.

    1976-01-01

    A new astronaut glove, the Evaporative Cooling/Heating Glove System (ECHGS), was designed and developed to allow the handling of objects between -200 F and +200 F. Active heating elements, positioned at each finger pad, provide additional heat to the finger pads from the rest of the finger. A water evaporative cooling system provides cooling by the injection of water to the finger areas and the subsequent direct evaporation to space. Thin, flexible insulation has been developed for the finger areas to limit thermal conductivity. Component and full glove tests have shown that the glove meets and exceeds the requirements to hold a 11/2 inch diameter bar at + or - 200 F for three minutes within comfort limits. The ECHGS is flexible, lightweight and comfortable. Tactility is reasonable and small objects can be identified especially by the fingertips beyond the one half width active elements.

  15. Prototype solar heating and cooling systems

    NASA Technical Reports Server (NTRS)

    1979-01-01

    A combination of monthly progress reports are presented. It contains a summary of activities and progress made from November 1, 1978, to February 28, 1979. The effort calls for the development, manufacture, test, system installation, maintenance, problem resolution, and performance evaluation.

  16. Energy Integrated Lighting-Heating-Cooling System.

    ERIC Educational Resources Information Center

    Meckler, Gershon; And Others

    1964-01-01

    Energy balance problems in the design of office buildings are analyzed. Through the use of integrated systems utilizing dual purpose products, a controlled environment with minimum expenditure of energy, equipment and space can be provided. Contents include--(1) office building occupancy loads, (2) office building heating load analysis, (3) office…

  17. Role of condenser iris in optical tweezer detection system.

    PubMed

    Samadi, Akbar; Reihani, S Nader S

    2011-10-15

    Optical tweezers have proven to be very useful in various scientific fields, from biology to nanotechnology. In this Letter we show, both by theory and experiment, that the interference intensity pattern at the back focal plane of the condenser consists of two distinguishable areas with anticorrelated intensity changes when the bead is moved in the axial direction. We show that the space angle defining the border of two areas linearly depends on the NA of the objective. We also propose a new octant photodiode, which could significantly improve the axial resolution compared to the commonly used quadrant photodiode technique. PMID:22002384

  18. PH adjustment of power plant cooling water with flue gas/fly ash

    DOEpatents

    Brady, Patrick V.; Krumhansl, James L.

    2015-09-22

    A system including a vessel including a heat source and a flue; a turbine; a condenser; a fluid conduit circuit disposed between the vessel, the turbine and the condenser; and a diverter coupled to the flue to direct a portion of an exhaust from the flue to contact with a cooling medium for the condenser water. A method including diverting a portion of exhaust from a flue of a vessel; modifying the pH of a cooling medium for a condenser with the portion of exhaust; and condensing heated fluid from the vessel with the pH modified cooling medium.

  19. Effect of working fluid on the performance of a miniature heat pipe system for cooling desktop processor

    NASA Astrophysics Data System (ADS)

    Uddin, Ahmed Imtiaz; Feroz, Chowdhury Md.

    2009-11-01

    The heat transfer performance of a miniature heat pipe system (MHPS) used for cooling a desktop computer processor is presented in this paper. The MHPS consists of 6 parallel cylindrical miniature heat pipes (MHPs) which are connected to a copper block at the evaporator section and which are provided with 15 parallel perpendicular copper sheets at the condenser section, used as external cooling fins. Acetone and ethanol are used as working fluids. As heat source a processor is employed which is attached to the copper block. Heat transfer characteristics of the individual MHPs and the complete MHPS using the two working fluids are experimentally determined. The results show that the maximum and steady state temperature of the processor has been significantly reduced by using MHPs with acetone, more than with ethanol, instead of a conventional finned aluminum heat sink with cooling fan. Additional use of a fan results in a much lower processor temperature for both working fluids.

  20. Gas cooled fuel cell systems technology development

    NASA Technical Reports Server (NTRS)

    Feret, J. M.

    1983-01-01

    The first phase of a planned multiphase program to develop a Phosphoric is addressed. This report describes the efforts performed that culminated in the: (1) Establishment of the preliminary design requirements and system conceptual design for the nominally rated 375 kW PAFC module and is interfacing power plant systems; (2) Establishment of PAFC component and stack performance, endurance, and design parameter data needed for design verification for power plant application; (3) Improvement of the existing PAFC materials data base and establishment of materials specifications and process procedes for the cell components; and (4) Testing of 122 subscale cell atmospheric test for 110,000 cumulative test hours, 12 subscale cell pressurized tests for 15,000 cumulative test hours, and 12 pressurized stack test for 10,000 cumulative test hours.

  1. He-3 cooling systems for space

    NASA Technical Reports Server (NTRS)

    Kittel, P.

    1984-01-01

    The development of a space-compatible He(3) refrigerator would provide a significant improvement in several areas of research in the 0.3 to 1 K temperature range. There are several methods of achieving these temperatures on Earth: He(3) refrigeration, dilution refrigeration, and adiabatic demagnetization refrigeration. The progress of adapting He(3) refrigeration for use in space is described. Various cycles and possible embodiments of He(3) refrigerators are described. Also included is an analysis of the liquid confinement and liquid-vapor phase-separation system. A possible configuration is then analyzed. Finally, the results of ground-based experiments will be discussed.

  2. Development and test of a cryogenic pulsating heat pipe and a pre-cooling system

    NASA Astrophysics Data System (ADS)

    Bonnet, Fabien; Gully, Philippe; Nikolayev, Vadim

    2012-06-01

    The needs of thermal links in cryogenic applications are increasing, especially because of the use of cryocoolers which offer a reduced size cold finger. The Pulsating Heat Pipe (PHP) is a passive two-phase high performance thermal link. Like the conventional heat pipe, it features a closed tube filled with a two-phase fluid able to transfer heat from its hot part (evaporator) to the cold part (condenser). A general problem for any two-phase cryogenic thermal link is the pre-cooling of the evaporator to ensure the presence of liquid inside the evaporator to start the flow motion. In conventional heat pipes, this problem is by passed by the wick but in the case of PHPs it has to be specially addressed. We have designed, manufactured and tested a helium PHP associated to a novel pre-cooling system. The cool down time of the PHP evaporator is reduced significantly. The maximum transferred power of the PHP is 145 mW with a cold source at 4.2 K.

  3. Corrosion inhibitors for solar heating and cooling systems

    NASA Technical Reports Server (NTRS)

    Humphries, T. S.; Deramus, G. E., Jr.

    1977-01-01

    Problems dealing with corrosion and corrosion protection of solar heating and cooling systems are discussed. A test program was conducted to find suitable and effective corrosion inhibitors for systems employing either water or antifreeze solutions for heat transfer and storage. Aluminum-mild-steel-copper-stainless steel assemblies in electrical contact were used to simulate a multimetallic system which is the type most likely to be employed. Several inhibitors show promise for this application.

  4. BETTER DUCT SYSTEMS FOR HOME HEATING AND COOLING.

    SciTech Connect

    ANDREWS,J.

    2001-01-01

    This is a series of six guides intended to provide a working knowledge of residential heating and cooling duct systems, an understanding of the major issues concerning efficiency, comfort, health, and safety, and practical tips on installation and repair of duct systems. These guides are intended for use by contractors, system designers, advanced technicians, and other HVAC professionals. The first two guides are also intended to be accessible to the general reader.

  5. Development of an Integrated Residential Heating, Ventilation, Cooling, and Dehumidification System for Residences

    SciTech Connect

    Hoeschele, M.A.; D.A. Springer

    2008-06-18

    The Need and the Opportunity Codes such as ASHRAE 90.2 and IECC, and programs such as Energy Star and Builders Challenge, are causing new homes to be built to higher performance standards. As a result sensible cooling loads in new homes are going down, but indoor air quality prerogatives are causing ventilation rates and moisture loads to increase in humid climates. Conventional air conditioners are unable to provide the low sensible heat ratios that are needed to efficiently cool and dehumidify homes since dehumidification potential is strongly correlated with cooling system operating hours. The project team saw an opportunity to develop a system that is at least as effective as a conventional air conditioner plus dehumidifier, removes moisture without increasing the sensible load, reduces equipment cost by integrating components, and simplifies installation. Project Overview Prime contractor Davis Energy Group led a team in developing an Integrated Heating, Ventilation, Cooling, and Dehumidification (I-HVCD) system under the DOE SBIR program. Phase I and II SBIR project activities ran from July 2003 through December 2007. Tasks included: (1) Mechanical Design and Prototyping; (2) Controls Development; (3) Laboratory and Field Testing; and (4) Commercialization Activities Technology Description. Key components of the prototype I-HVCD system include an evaporator coil assembly, return and outdoor air damper, and controls. These are used in conjunction with conventional components that include a variable speed air handler or furnace, and a two-stage condensing unit. I-HVCD controls enable the system to operate in three distinct cooling modes to respond to indoor temperature and relative humidity (RH) levels. When sensible cooling loads are high, the system operates similar to a conventional system but varies supply airflow in response to indoor RH. In the second mode airflow is further reduced, and the reheat coil adds heat to the supply air. In the third mode, the

  6. Solar Heating and Cooling of Residential Buildings: Design of Systems.

    ERIC Educational Resources Information Center

    Colorado State Univ., Ft. Collins. Solar Energy Applications Lab.

    This is the second of two training courses designed to develop the capability of practitioners in the home building industry to design solar heating and cooling systems. The course is organized in 23 modules to separate selected topics and to facilitate learning. Although a compact schedule of one week is shown, a variety of formats can be…

  7. Twelve solar-heating/cooling systems: Design and development

    NASA Technical Reports Server (NTRS)

    1980-01-01

    Two quarterly reports describe first 6 months of development on single family, multifamily, and commercial installations in Minneapolis area. Reports discuss basic requirements, and reasons for selecting specific configurations. Systems consist of liquid cooled flat plate collectors, two fluid loops, and gas-fired forced-air auxiliary heat source.

  8. Cooling System: Automotive Mechanics Instructional Program. Block 6.

    ERIC Educational Resources Information Center

    O'Brien, Ralph D.

    The last of six instructional blocks in automotive mechanics, the lessons and supportive information in the document provide a guide for teachers in planning an instructional program in the automotive cooling system at the secondary and post secondary level. The material, as organized, is a suggested sequence of instruction within each block. Each…

  9. System design package for a solar heating and cooling system installed at Akron, Ohio

    NASA Technical Reports Server (NTRS)

    1979-01-01

    Information used to evaluate the design of a solar heating, cooling, and domestic hot water system is given. A conventional heat pump provides summer cooling items as the design data brochure, system performance specification, system hazard analysis, spare parts list, and detailed design drawings. A solar system is installed in a single-family dwelling at Akron, Ohio, and at Duffield, Virginia.

  10. Air conditioning system with supplemental ice storing and cooling capacity

    DOEpatents

    Weng, Kuo-Lianq; Weng, Kuo-Liang

    1998-01-01

    The present air conditioning system with ice storing and cooling capacity can generate and store ice in its pipe assembly or in an ice storage tank particularly equipped for the system, depending on the type of the air conditioning system. The system is characterized in particular in that ice can be produced and stored in the air conditioning system whereby the time of supplying cooled air can be effectively extended with the merit that the operation cycle of the on and off of the compressor can be prolonged, extending the operation lifespan of the compressor in one aspect. In another aspect, ice production and storage in great amount can be performed in an off-peak period of the electrical power consumption and the stored ice can be utilized in the peak period of the power consumption so as to provide supplemental cooling capacity for the compressor of the air conditioning system whereby the shift of peak and off-peak power consumption can be effected with ease. The present air conditioning system can lower the installation expense for an ice-storing air conditioning system and can also be applied to an old conventional air conditioning system.

  11. The integration of cryogenic cooling systems with superconducting electronic systems

    SciTech Connect

    Green, Michael A.

    2003-07-01

    The need for cryogenic cooling has been critical issue that has kept superconducting electronic devices from reaching the market place. Even though the performance of the superconducting circuit is superior to silicon electronics, the requirement for cryogenic cooling has put the superconducting devices at a disadvantage. This report will talk about the various methods for refrigerating superconducting devices. Cryocooler types will be compared for vibration, efficiency, and cost. Some solutions to specific problems of integrating cryocoolers to superconducting devices are presented.

  12. Successful water reuse in open recirculating cooling systems

    SciTech Connect

    Vaska, M.; Lee, B.

    1994-12-31

    Water reuse in open recirculating cooling water systems is becoming increasingly prevalent in industry. Reuse can incorporate a number of varied approaches with the primary goal being water conservation. Market forces driving this trend include scarcity of fresh water makeup sources and higher costs associated with pretreatment of natural waters. Utilization of reuse water for cooling tower makeup has especially detrimental effects on corrosion and deposit rates. Additionally, once the reuse water is cycled and treated with inhibitors, dispersants and microbiocides, acceptability for discharge to a public waterway can be a concern. The task for water treatment suppliers is to guide industry in the feasibility and procedures for successfully achieving these goals. This paper focuses particularly on reuse of municipal wastewater for cooling tower makeup and explores techniques which have been found especially effective. Case histories are described where these concepts have been successfully applied in practice.

  13. Solar heating and cooling system installed at Leavenworth, Kansas

    NASA Technical Reports Server (NTRS)

    1980-01-01

    A solar heating and cooling is described which is designed to furnish 90 percent of the overall heating load, 70 percent of the cooling load and 100 percent of the domestic hot water load. The building has two floors with a total of 12,000 square feet gross area. The system has 120 flat-plate liquid solar panels with a net area of 2,200 square feet. Five 3 ton Arkla solar assisted absorption units provide the cooling, in conjunction with a 3,000 gallon chilled water storage tank. Two 3,000 gallon storage tanks are provided with one designated for summer use, whereas both tanks are utilized during winter.

  14. Solar heating and cooling system installed at Leavenworth, Kansas

    NASA Astrophysics Data System (ADS)

    1980-06-01

    A solar heating and cooling is described which is designed to furnish 90 percent of the overall heating load, 70 percent of the cooling load and 100 percent of the domestic hot water load. The building has two floors with a total of 12,000 square feet gross area. The system has 120 flat-plate liquid solar panels with a net area of 2,200 square feet. Five 3 ton Arkla solar assisted absorption units provide the cooling, in conjunction with a 3,000 gallon chilled water storage tank. Two 3,000 gallon storage tanks are provided with one designated for summer use, whereas both tanks are utilized during winter.

  15. Condensate polishers add operating reliability and flexibility

    SciTech Connect

    Layman, C.M.; Bennett, L.L.

    2008-08-15

    Many of today's advanced steam generators favour either an all-volatile treatment or oxygenated treatment chemistry programme, both of which require strict maintenance of an ultra-pure boiler fedwater ro condensate system. Those requirements are many times at odds with the lower-quality water sources, such as greywater, available for plant makeup and cooling water. Adding a condensate polisher can be a simple, cost-effective solution. 4 figs.

  16. Computational Fluid Dynamics Analysis of Very High Temperature Gas-Cooled Reactor Cavity Cooling System

    SciTech Connect

    Frisani, Angelo; Hassan, Yassin A; Ugaz, Victor M

    2010-11-02

    The design of passive heat removal systems is one of the main concerns for the modular very high temperature gas-cooled reactors (VHTR) vessel cavity. The reactor cavity cooling system (RCCS) is a key heat removal system during normal and off-normal conditions. The design and validation of the RCCS is necessary to demonstrate that VHTRs can survive to the postulated accidents. The computational fluid dynamics (CFD) STAR-CCM+/V3.06.006 code was used for three-dimensional system modeling and analysis of the RCCS. A CFD model was developed to analyze heat exchange in the RCCS. The model incorporates a 180-deg section resembling the VHTR RCCS experimentally reproduced in a laboratory-scale test facility at Texas A&M University. All the key features of the experimental facility were taken into account during the numerical simulations. The objective of the present work was to benchmark CFD tools against experimental data addressing the behavior of the RCCS following accident conditions. Two cooling fluids (i.e., water and air) were considered to test the capability of maintaining the RCCS concrete walls' temperature below design limits. Different temperature profiles at the reactor pressure vessel (RPV) wall obtained from the experimental facility were used as boundary conditions in the numerical analyses to simulate VHTR transient evolution during accident scenarios. Mesh convergence was achieved with an intensive parametric study of the two different cooling configurations and selected boundary conditions. To test the effect of turbulence modeling on the RCCS heat exchange, predictions using several different turbulence models and near-wall treatments were evaluated and compared. The comparison among the different turbulence models analyzed showed satisfactory agreement for the temperature distribution inside the RCCS cavity medium and at the standpipes walls. For such a complicated geometry and flow conditions, the tested turbulence models demonstrated that the

  17. Developing, testing, evaluating and optimizing solar heating and cooling systems

    SciTech Connect

    Not Available

    1991-11-01

    The objective is to develop and test various integrated solar heating, cooling and domestic hot water systems, and to evaluate their performance. Systems composed of new, as well a previously tested, components are carefully integrated so that effects of new components on system performance can be clearly delineated. The SEAL-DOE program includes six tasks which have received funding for the 1991--1992 fifteen-month period. These include: (1) a project employing isothermal operation of air and liquid solar space hearing systems, (2) a project to build and test several generic solar water heaters, (3) a project that will evaluate advanced solar domestic hot water components and concepts and integrate them into solar domestic hot water systems, (4) a liquid desiccant cooling system development project, (5) a project that will perform system modeling and analysis work on solid desiccant cooling systems research, and (6) a management task. The objectives and progress in each task are described in this report. 6 figs., 2 tabs.

  18. Experimental Studies of NGNP Reactor Cavity Cooling System With Water

    SciTech Connect

    Corradini, Michael; Anderson, Mark; Hassan, Yassin; Tokuhiro, Akira

    2013-01-16

    This project will investigate the flow behavior that can occur in the reactor cavity cooling system (RCCS) with water coolant under the passive cooling-mode of operation. The team will conduct separate-effects tests and develop associated scaling analyses, and provide system-level phenomenological and computational models that describe key flow phenomena during RCCS operation, from forced to natural circulation, single-phase flow and two-phase flow and flashing. The project consists of the following tasks: Task 1. Conduct separate-effects, single-phase flow experiments and develop scaling analyses for comparison to system-level computational modeling for the RCCS standpipe design. A transition from forced to natural convection cooling occurs in the standpipe under accident conditions. These tests will measure global flow behavior and local flow velocities, as well as develop instrumentation for use in larger scale tests, thereby providing proper flow distribution among standpipes for decay heat removal. Task 2. Conduct separate-effects experiments for the RCCS standpipe design as two-phase flashing occurs and flow develops. As natural circulation cooling continues without an ultimate heat sink, water within the system will heat to temperatures approaching saturation , at which point two-phase flashing and flow will begin. The focus is to develop a phenomenological model from these tests that will describe the flashing and flow stability phenomena. In addition, one could determine the efficiency of phase separation in the RCCS storage tank as the two-phase flashing phenomena ensues and the storage tank vents the steam produced. Task 3. Develop a system-level computational model that will describe the overall RCCS behavior as it transitions from forced flow to natural circulation and eventual two-phase flow in the passive cooling-mode of operation. This modeling can then be used to test the phenomenological models developed as a function of scale.

  19. Interfacial Charge Transfer States in Condensed Phase Systems

    NASA Astrophysics Data System (ADS)

    Vandewal, Koen

    2016-05-01

    Intermolecular charge transfer (CT) states at the interface between electron-donating (D) and electron-accepting (A) materials in organic thin films are characterized by absorption and emission bands within the optical gap of the interfacing materials. CT states efficiently generate charge carriers for some D-A combinations, and others show high fluorescence quantum efficiencies. These properties are exploited in organic solar cells, photodetectors, and light-emitting diodes. This review summarizes experimental and theoretical work on the electronic structure and interfacial energy landscape at condensed matter D-A interfaces. Recent findings on photogeneration and recombination of free charge carriers via CT states are discussed, and relations between CT state properties and optoelectronic device parameters are clarified.

  20. Interfacial Charge Transfer States in Condensed Phase Systems.

    PubMed

    Vandewal, Koen

    2016-05-27

    Intermolecular charge transfer (CT) states at the interface between electron-donating (D) and electron-accepting (A) materials in organic thin films are characterized by absorption and emission bands within the optical gap of the interfacing materials. CT states efficiently generate charge carriers for some D-A combinations, and others show high fluorescence quantum efficiencies. These properties are exploited in organic solar cells, photodetectors, and light-emitting diodes. This review summarizes experimental and theoretical work on the electronic structure and interfacial energy landscape at condensed matter D-A interfaces. Recent findings on photogeneration and recombination of free charge carriers via CT states are discussed, and relations between CT state properties and optoelectronic device parameters are clarified. PMID:26980308

  1. Hydraulic tests of emergency cooling system: L-Area

    SciTech Connect

    Hinton, J H

    1988-01-01

    The delay in L-Area startup provided an opportunity to obtain valuable data on the Emergency Cooling System (ECS) which will permit reactor operation at the highest safe power level. ECS flow is a major input to the FLOOD code which calculates reactor ECS power limits. The FLOOD code assesses the effectiveness of the ECS cooling capacity by modeling the core and plenum hydraulics under accident conditions. Presently, reactor power is not limited by the ECS cooling capacity (power limit). However, the manual calculations of ECS flows had been recently updated to include piping changes (debris strainer, valve changes, pressure release systems) and update fitting losses. Both updates resulted in reduced calculated ECS flows. Upon completion of the current program to update, validate, and document, reactor power may be limited under certain situations by ECS cooling capacity for some present reactor charge designs. A series of special hydraulic tests (Reference 1, 3) were conducted in L-Area using all sources of emergency coolant including the ECS pumps (Reference 2). The tests provided empirical hydraulic data on the ECS piping. These data will be used in computer models of the system as well as manual calculations of ECS flows. The improved modeling and accuracy of the flow calculations will permit reactor operation at the highest safe power level with respect to an ECS power limit.

  2. Turbine airfoil with an internal cooling system having vortex forming turbulators

    DOEpatents

    Lee, Ching-Pang

    2014-12-30

    A turbine airfoil usable in a turbine engine and having at least one cooling system is disclosed. At least a portion of the cooling system may include one or more cooling channels having a plurality of turbulators protruding from an inner surface and positioned generally nonorthogonal and nonparallel to a longitudinal axis of the airfoil cooling channel. The configuration of turbulators may create a higher internal convective cooling potential for the blade cooling passage, thereby generating a high rate of internal convective heat transfer and attendant improvement in overall cooling performance. This translates into a reduction in cooling fluid demand and better turbine performance.

  3. The Analysis of A Hybrid Cooling System - Phase 2,

    NASA Astrophysics Data System (ADS)

    Yang, Kuan-Hsiung

    During the first phase of study, the mathematical modelling and the performance of the hybrid cooling system using solid desiccants were analyzed numerically. During this phase of study, the experimental investigation was conducted which yielded successful results with 5 % deviation as compared with the operational data of available commerical dehumidifiers. Furthmore, a prototype hybrid cooling system was actually constructed in the Refrigeration & Air-Conditioning Lab of National Sun Yat-Sen University (NSYSU), which generated good correlations with 7% deviation only, as compared with the analytical results. In other words, the good correlations obtained among the math modeling, the commercial unit operational data, and the NSYSU prototype system warrant the potential applications of this system for many industrial dehumidification and drying processes.

  4. CFD Model Development and validation for High Temperature Gas Cooled Reactor Cavity Cooling System (RCCS) Applications

    SciTech Connect

    Hassan, Yassin; Corradini, Michael; Tokuhiro, Akira; Wei, Thomas Y.C.

    2014-07-14

    The Reactor Cavity Cooling Systems (RCCS) is a passive safety system that will be incorporated in the VTHR design. The system was designed to remove the heat from the reactor cavity and maintain the temperature of structures and concrete walls under desired limits during normal operation (steady-state) and accident scenarios. A small scale (1:23) water-cooled experimental facility was scaled, designed, and constructed in order to study the complex thermohydraulic phenomena taking place in the RCCS during steady-state and transient conditions. The facility represents a portion of the reactor vessel with nine stainless steel coolant risers and utilizes water as coolant. The facility was equipped with instrumentation to measure temperatures and flow rates and a general verification was completed during the shakedown. A model of the experimental facility was prepared using RELAP5-3D and simulations were performed to validate the scaling procedure. The experimental data produced during the steady-state run were compared with the simulation results obtained using RELAP5-3D. The overall behavior of the facility met the expectations. The facility capabilities were confirmed to be very promising in performing additional experimental tests, including flow visualization, and produce data for code validation.

  5. Use of Cooling Thermal Storage as a Heat Sink for Steam Power Plant

    NASA Astrophysics Data System (ADS)

    Hegazy, Ahmed Sabry

    In the present paper, a system is proposed for improving the performance of steam power plant with air-cooled condenser during peak loads. In this system, the power plant comprises two steam turbines, and the air-cooled condenser is replaced by two condensers. The first one is air-cooled (dry) and used for condensing the exhaust steam of the first turbine, while the second is water-cooled and serves to condense the steam outlet of the second turbine. The warm cooling water exiting the wet condenser is pumped to a cooling storage container, where it is cooled and re-circulated to the wet condenser. Cooling is produced by a refrigeration machine driven by the extra electric power generated by the two turbines during the time of the off-peak-loads (low electricity rates). Simple energy analyses have been developed to predict the energy characteristics of this system. The results of this paper showed that the proposed system leads to improving the plant power output at peak-loads. About 6, 16, 24 and 33% increase in generated plant power can be achieved at peak-loads (high electricity rates) when the ambient temperature is 20, 30, 40 and 50°C respectively, and the whole steam exiting both turbines is cooled in a wet condenser to a design temperature of 20°C. The results showed also that choice of the capacity of each turbine is essentially affected by the quality of the refrigeration machine and ambient temperature.

  6. Heat pipe cooling system with sensible heat sink

    NASA Technical Reports Server (NTRS)

    Silverstein, Calvin C.

    1988-01-01

    A heat pipe cooling system which employs a sensible heat sink is discussed. With this type of system, incident aerodynamic heat is transported via a heat pipe from the stagnation region to the heat sink and absorbed by raising the temperature of the heat sink material. The use of a sensible heat sink can be advantageous for situations where the total mission heat load is limited, as it is during re-entry, and a suitable radiation sink is not available.

  7. Correcting Aberrations in Complex Magnet Systems for Muon Cooling Channels

    SciTech Connect

    J.A. Maloney, B. Erdelyi, A. Afanaciev, R.P. Johnson, Y.S. Derbenev, V.S. Morozov

    2011-03-01

    Designing and simulating complex magnet systems needed for cooling channels in both neutrino factories and muon colliders requires innovative techniques to correct for both chromatic and spherical aberrations. Optimizing complex systems, such as helical magnets for example, is also difficult but essential. By using COSY INFINITY, a differential algebra based code, the transfer and aberration maps can be examined to discover what critical terms have the greatest influence on these aberrations.

  8. Method and system for powering and cooling semiconductor lasers

    SciTech Connect

    Telford, Steven J; Ladran, Anthony S

    2014-02-25

    A semiconductor laser system includes a diode laser tile. The diode laser tile includes a mounting fixture having a first side and a second side opposing the first side and an array of semiconductor laser pumps coupled to the first side of the mounting fixture. The semiconductor laser system also includes an electrical pulse generator thermally coupled to the diode bar and a cooling member thermally coupled to the diode bar and the electrical pulse generator.

  9. Alkali Metal Backup Cooling for Stirling Systems - Experimental Results

    NASA Technical Reports Server (NTRS)

    Schwendeman, Carl; Tarau, Calin; Anderson, William G.; Cornell, Peggy A.

    2013-01-01

    In a Stirling Radioisotope Power System (RPS), heat must be continuously removed from the General Purpose Heat Source (GPHS) modules to maintain the modules and surrounding insulation at acceptable temperatures. The Stirling convertor normally provides this cooling. If the Stirling convertor stops in the current system, the insulation is designed to spoil, preventing damage to the GPHS at the cost of an early termination of the mission. An alkali-metal Variable Conductance Heat Pipe (VCHP) can be used to passively allow multiple stops and restarts of the Stirling convertor. In a previous NASA SBIR Program, Advanced Cooling Technologies, Inc. (ACT) developed a series of sodium VCHPs as backup cooling systems for Stirling RPS. The operation of these VCHPs was demonstrated using Stirling heater head simulators and GPHS simulators. In the most recent effort, a sodium VCHP with a stainless steel envelope was designed, fabricated and tested at NASA Glenn Research Center (GRC) with a Stirling convertor for two concepts; one for the Advanced Stirling Radioisotope Generator (ASRG) back up cooling system and one for the Long-lived Venus Lander thermal management system. The VCHP is designed to activate and remove heat from the stopped convertor at a 19 C temperature increase from the nominal vapor temperature. The 19 C temperature increase from nominal is low enough to avoid risking standard ASRG operation and spoiling of the Multi-Layer Insulation (MLI). In addition, the same backup cooling system can be applied to the Stirling convertor used for the refrigeration system of the Long-lived Venus Lander. The VCHP will allow the refrigeration system to: 1) rest during transit at a lower temperature than nominal; 2) pre-cool the modules to an even lower temperature before the entry in Venus atmosphere; 3) work at nominal temperature on Venus surface; 4) briefly stop multiple times on the Venus surface to allow scientific measurements. This paper presents the experimental

  10. Alkali Metal Backup Cooling for Stirling Systems - Experimental Results

    NASA Technical Reports Server (NTRS)

    Schwendeman, Carl; Tarau, Calin; Anderson, William G.; Cornell, Peggy A.

    2013-01-01

    In a Stirling Radioisotope Power System (RPS), heat must be continuously removed from the General Purpose Heat Source (GPHS) modules to maintain the modules and surrounding insulation at acceptable temperatures. The Stirling convertor normally provides this cooling. If the Stirling convertor stops in the current system, the insulation is designed to spoil, preventing damage to the GPHS at the cost of an early termination of the mission. An alkali-metal Variable Conductance Heat Pipe (VCHP) can be used to passively allow multiple stops and restarts of the Stirling convertor. In a previous NASA SBIR Program, Advanced Cooling Technologies, Inc. (ACT) developed a series of sodium VCHPs as backup cooling systems for Stirling RPS. The operation of these VCHPs was demonstrated using Stirling heater head simulators and GPHS simulators. In the most recent effort, a sodium VCHP with a stainless steel envelope was designed, fabricated and tested at NASA Glenn Research Center (GRC) with a Stirling convertor for two concepts; one for the Advanced Stirling Radioisotope Generator (ASRG) back up cooling system and one for the Long-lived Venus Lander thermal management system. The VCHP is designed to activate and remove heat from the stopped convertor at a 19 degC temperature increase from the nominal vapor temperature. The 19 degC temperature increase from nominal is low enough to avoid risking standard ASRG operation and spoiling of the Multi-Layer Insulation (MLI). In addition, the same backup cooling system can be applied to the Stirling convertor used for the refrigeration system of the Long-lived Venus Lander. The VCHP will allow the refrigeration system to: 1) rest during transit at a lower temperature than nominal; 2) pre-cool the modules to an even lower temperature before the entry in Venus atmosphere; 3) work at nominal temperature on Venus surface; 4) briefly stop multiple times on the Venus surface to allow scientific measurements. This paper presents the experimental

  11. Next-Generation Evaporative Cooling Systems for the Advanced Extravehicular Mobility Unit Portable Life Support System

    NASA Technical Reports Server (NTRS)

    Makinen, Janice V.; Anchondo, Ian; Bue, Grant C.; Campbell, Colin; Colunga, Aaron

    2012-01-01

    The development of the Advanced Extravehicular Mobility Unit (AEMU) Portable Life Support System (PLSS) is currently underway at NASA Johnson Space Center. The AEMU PLSS features two new evaporative cooling systems, the Reduced Volume Prototype Spacesuit Water Membrane Evaporator (RVP SWME), and the Auxiliary Cooling Loop (ACL). The RVP SWME is the third generation of hollow fiber SWME hardware, and like its predecessors, RVP SWME provides nominal crewmember and electronics cooling by flowing water through porous hollow fibers. Water vapor escapes through the hollow fiber pores, thereby cooling the liquid water that remains inside of the fibers. This cooled water is then recirculated to remove heat from the crewmember and PLSS electronics. Major design improvements, including a 36% reduction in volume, reduced weight, and more flight like back-pressure valve, facilitate the packaging of RVP SWME in the AEMU PLSS envelope. In addition to the RVP SWME, the Auxiliary Cooling Loop (ACL), was developed for contingency crewmember cooling. The ACL is a completely redundant, independent cooling system that consists of a small evaporative cooler--the Mini Membrane Evaporator (Mini-ME), independent pump, independent feed-water assembly and independent Liquid Cooling Garment (LCG). The Mini-ME utilizes the same hollow fiber technology featured in the RVP SWME, but is only 25% of the size of RVP SWME, providing only the necessary crewmember cooling in a contingency situation. The ACL provides a number of benefits when compared with the current EMU PLSS contingency cooling technology; contingency crewmember cooling can be provided for a longer period of time, more contingency situations can be accounted for, no reliance on a Secondary Oxygen Vessel (SOV) for contingency cooling--thereby allowing a SOV reduction in size and pressure, and the ACL can be recharged-allowing the AEMU PLSS to be reused, even after a contingency event. The development of these evaporative cooling

  12. Analysis of advanced solar hybrid desiccant cooling systems for buildings

    SciTech Connect

    Schlepp, D.; Schultz, K.

    1984-10-01

    This report describes an assessment of the energy savings possible from developing hybrid desiccant/vapor-compression air conditioning systems. Recent advances in dehumidifier design for solar desiccant cooling systems have resulted in a dehumidifier with a low pressure drop and high efficiency in heat and mass transfer. A recent study on hybrid desiccant/vapor compression systems showed a 30%-80% savings in resource energy when compared with the best conventional systems with vapor compression. A system consisting of a dehumidifier with vapor compression subsystems in series was found to be the simplest and best overall performer.

  13. Cooling system for vertical shaft V-type engine

    SciTech Connect

    Tamba, S.; Fukui, N.; Miguchi, A.

    1988-07-12

    A cooling system in a V-type engine is described having a crankcase with cylinders arranged horizontally and so as to form a V therebetween, a bottom wall attached to the crankcase at a level lower than the cylinders, and a vertically arranged crankshaft substantially at the junction of the V. The cooling system consists of: a coolant pump having a pump shaft arranged parallel to the crankshaft, within the V spaced from the junction, and spaced from the cylinders vertically in axial direction of the crankshaft; the coolant pump being joined to a first face of the bottom wall of the crankcase and having outlet passages extending orthogonal to the crankshaft and ending at the first face of the bottom wall, separate cooling jackets mounted at the cylinders and having therein separate inlets at a second face of the bottom wall of the crankcase, and intermediate coolant passages provided within the bottom wall between the first and second faces and joining the outlet passages to the inlets of the cooling jackets.

  14. CARMENES ultra-stable cooling system: very promising results

    NASA Astrophysics Data System (ADS)

    Mirabet, E.; Carvas, P.; Lizon, J.-L.; Becerril, S.; Rodríguez, E.; Abril, M.; Cárdenas, M. C.; Morales, R.; Pérez, D.; Sánchez Carrasco, M. A.; Amado, P. J.; Seifert, W.; Quirrenbach, A.; Caballero, J. A.; Ribas, I.; Reiners, A.; Dreizler, S.

    2014-07-01

    CARMENES is a high resolution spectrograph to detect planets through the variation of radial velocity, destined for the Calar Alto Observatory in Almeria, Spain. The optical bench has a working temperature of 140K with a 24 hours stability of ±0,1K; goal ±0,01K. It is enclosed with a radiation shield actively cooled with thermalized nitrogen gas that flows through strategically positioned heat exchangers to remove its radiative load. The cooling system has an external preparation unit (N2GPU), which provides the nitrogen gas through actively vaporizing liquid nitrogen with heating resistances and a three stage circuit flow, each one controlled by an independent PID. Since CARMENES is still in the construction phase, a dedicated test facility has been built in order to simulate the instrument and correctly establish the N2GPU parameters. Furthermore, the test facility allows a wide range of configurations set-ups, which enables a full characterization of the N2GPU and the cooling system. The N2GPU has been designed to offer a wide temperature range of thermally stabilized nitrogen gas flow, which apart from CARMENES could also be used to provide ultra-high thermal stability in other cryogenic instruments. The present paper shows the testing of the cooling performance, the hardware used and the very promising results obtained.

  15. NMR quadrupolar system described as Bose-Einstein-condensate-like system

    SciTech Connect

    Auccaise, R.; Oliveira, I. S.; Sarthour, R. S.; Teles, J.; Bonagamba, T. J.; Azevedo, E. R. de

    2009-04-14

    This paper presents a description of nuclear magnetic resonance (NMR) of quadrupolar systems using the Holstein-Primakoff (HP) formalism and its analogy with a Bose-Einstein condensate (BEC) system. Two nuclear spin systems constituted of quadrupolar nuclei I=3/2 ({sup 23}Na) and I=7/2 ({sup 133}Cs) in lyotropic liquid crystals were used for experimental demonstrations. Specifically, we derived the conditions necessary for accomplishing the analogy, executed the proper experiments, and compared with quantum mechanical prediction for a Bose system. The NMR description in the HP representation could be applied in the future as a workbench for BEC-like systems, where the statistical properties may be obtained using the intermediate statistic, first established by Gentile. The description can be applied for any quadrupolar systems, including new developed solid-state NMR GaAS nanodevices.

  16. Experimental study of high-performance cooling system pipeline diameter and working fluid amount

    NASA Astrophysics Data System (ADS)

    Nemec, Patrik; Malcho, Milan; Hrabovsky, Peter; Papučík, Štefan

    2016-03-01

    This work deals with heat transfer resulting from the operation of power electronic components. Heat is removed from the mounting plate, which is the evaporator of the loop thermosyphon to the condenser and by natural convection is transferred to ambient. This work includes proposal of cooling device - loop thermosyphon, with its construct and follow optimization of cooling effect. Optimization proceeds by selecting the quantity of working fluid and selection of diameters vapour line and liquid line of loop thermosyphon.

  17. Triple-effect absorption refrigeration system with double-condenser coupling

    DOEpatents

    DeVault, Robert C.; Biermann, Wendell J.

    1993-01-01

    A triple effect absorption refrigeration system is provided with a double-condenser coupling and a parallel or series circuit for feeding the refrigerant-containing absorbent solution through the high, medium, and low temperature generators utilized in the triple-effect system. The high temperature condenser receiving vaporous refrigerant from the high temperature generator is double coupled to both the medium temperature generator and the low temperature generator to enhance the internal recovery of heat within the system and thereby increase the thermal efficiency thereof.

  18. Triple-effect absorption refrigeration system with double-condenser coupling

    DOEpatents

    DeVault, R.C.; Biermann, W.J.

    1993-04-27

    A triple effect absorption refrigeration system is provided with a double-condenser coupling and a parallel or series circuit for feeding the refrigerant-containing absorbent solution through the high, medium, and low temperature generators utilized in the triple-effect system. The high temperature condenser receiving vaporous refrigerant from the high temperature generator is double coupled to both the medium temperature generator and the low temperature generator to enhance the internal recovery of heat within the system and thereby increase the thermal efficiency thereof.

  19. A pumped two-phase cooling system for spacecraft

    NASA Technical Reports Server (NTRS)

    Ollendorf, S.; Costello, F. A.

    1983-01-01

    A pumped, two-phase heat-transport system is being developed for possible use for temperature control of scientific instruments on future NASA missions. As compared to a single-phase system, this two-phase system can maintain tighter temperature control with less pumping power. A laboratory model of the system has been built and tested. The measured heat transfer coefficients were approximately the same as in heat pipes, 220 Btu/hr-sq ft-F, as compared to 25 Btu/hr-sq ft-F for single-phase liquid flow. Heat shearing between experiments has been demonstrated wherein vapor generated in the cold plate of an active experiment was condensed in a cold, unheated experiment. System stability has been observed. However, additional development is needed. The use of non-azeotropic mixtures of coolants appears especially promising as a simple way to determine exit quality and thus control the flow rates to prevent dryout.

  20. MICE: The International Muon Ionization Cooling Experiment: Diagnostic Systems

    SciTech Connect

    Bross, Alan D.; Hart, Terrence Lee; /IIT, Chicago

    2008-06-24

    The Muon Ionization Cooling Experiment will make detailed measurements of muon ionization cooling using a new constructed low-energy muon beam at the Rutherford Appleton Laboratory (RAL). The experiment is a single-particle experiment and utilizes many detector techniques from high energy physics experiments. To characterize and monitor the muon beamline, newly developed scintillating fiber profile monitors and scintillator paddle rate monitors are employed. In order to monitor the purity of the beam and tag the arrival time of individual muons, a dual aerogel Cherenkov system is used, and a plastic scintillator time-of-flight system will be used. The phase-space vectors of the muons will be measured by two identical spectrometer systems (one before and one after the cooling apparatus) which employ a fiber tracker system, and electron and muon calorimeters are used to tag outgoing muons. We will discuss the design of the MICE diagnostic systems, the operation, and give the first results from beam measurements in the MICE experimental hall.

  1. Development of Personalized Radiant Cooling System for an Office Room

    SciTech Connect

    Khare, Vaibhav; Sharma, Anuj; Mathur, Jyotirmay; Bhandari, Mahabir S

    2015-01-01

    The building industry nowadays is facing two major challenges increased concern for energy reduction and growing need for thermal comfort. These challenges have led many researchers to develop Radiant Cooling Systems that show a large potential for energy savings. This study aims to develop a personalized cooling system using the principle of radiant cooling integrated with conventional all-air system to achieve better thermal environment at the workspace. Personalized conditioning aims to create a microclimatic zone around a single workspace. In this way, the energy is deployed only where it is actually needed, and the individual s needs for thermal comfort are fulfilled. To study the effect of air temperature along with air temperature distribution for workspace, air temperature near the vicinity of the occupant has been obtained as a result of Computational Fluid Dynamics (CFD) simulation using FLUENT. The analysis showed that personalized radiant system improves thermal environment near the workspace and allows all-air systems to work at higher thermostat temperature without compromising the thermal comfort, which in turn reduces its energy consumption.

  2. Experimental and Thermalhydraulic Code Assessment of the Transient Behavior of the Passive Condenser System in an Advanced Boiling Water Reactor

    SciTech Connect

    S.T. Revankar; W. Zhou; Gavin Henderson

    2008-07-08

    The main goal of the project was to study analytically and experimentally the condensation heat transfer for the passive condenser system such as GE Economic Simplified Boiling Water Reactor (ESBWR). The effect of noncondensable gas in condenser tube and the reduction of secondary pool water level to the condensation heat transfer coefficient was the main focus in this research. The objectives of this research were to : 1) obtain experimental data on the local and tube averaged condensation heat transfer rates for the PCCS with non-condensable and with change in the secondary pool water, 2) assess the RELAP5 and TRACE computer code against the experimental data, and 3) develop mathematical model and ehat transfer correlation for the condensation phenomena for system code application. The project involves experimentation, theoretical model development and verification, and thermal- hydraulic codes assessment.

  3. Experimental study on the double-evaporator thermosiphon for cooling HTS (high temperature superconductor) system

    NASA Astrophysics Data System (ADS)

    Lee, Junghyun; Ko, Junseok; Kim, Youngkwon; Jeong, Sangkwon; Sung, Taehyun; Han, Younghee; Lee, Jeong-Phil; Jung, Seyong

    2009-08-01

    A cryogenic thermosiphons is an efficient heat transfer device between a cryocooler and a thermal load that is to be cooled. This paper presents an idea of thermosiphon which contains two vertically-separated evaporators. This unique configuration of the thermosiphon is suitable for the purpose of cooling simultaneously two superconducting bearings of the HTS (high temperature superconducting) flywheel system at the same temperature. A so-called double-evaporator thermosiphon was designed, fabricated and tested using nitrogen as the working fluid under sub-atmospheric pressure condition. The interior thermal condition of the double-evaporator thermosiphon was examined in detail during its cool-down process according to the internal thermal states. The double-evaporator thermosiphon has operated successfully at steady-state operation under sub-atmospheric pressure. At the heat flow of 10.6 W, the total temperature difference of the thermosiphon was only 1.59 K and the temperature difference between the evaporators was 0.64 K. The temperature difference of two evaporators is attributed to the conductive thermal resistance of the adiabatic section between the evaporators. The method to reduce this temperature difference has been investigated and presented in this paper. The proper area selection of condenser, evaporator 1, and evaporator 2 was studied by using thermal resistance model to optimize the performance of a thermosiphon. The superior heat transfer characteristic of the double-evaporator thermosiphon without involving any cryogenic pump can be a great potential advantage for cooling HTS bulk modules that are separated vertically.

  4. Gas-cooled reactor power systems for space

    SciTech Connect

    Walter, C.E.

    1987-01-01

    Efficiency and mass characteristics for four gas-cooled reactor power system configurations in the 2- to 20-MWe power range are modeled. The configurations use direct and indirect Brayton cycles with and without regeneration in the power conversion loop. The prismatic ceramic core of the reactor consists of several thousand pencil-shaped tubes made from a homogeneous mixture of moderator and fuel. The heat rejection system is found to be the major contributor to system mass, particularly at high power levels. A direct, regenerated Brayton cycle with helium working fluid permits high efficiency and low specific mass for a 10-MWe system.

  5. Cryogenetically Cooled Field Effect Transistors for Low-Noise Systems

    NASA Technical Reports Server (NTRS)

    Wollack, Edward J.; Rabin, Douglas M. (Technical Monitor)

    2002-01-01

    Recent tends in the design, fabrication and use of High-Electron-Mobility-Transistors (HEMT) in low noise amplifiers are reviewed. Systems employing these devices have achieved the lowest system noise for wavelengths greater than three millimeters with relatively modest cryogenic cooling requirements in a variety of ground and space based applications. System requirements which arise in employing such devices in imaging applications are contrasted with other leading coherent detector candidates at microwave wavelengths. Fundamental and practical limitations which arise in the context of microwave application of field effect devices at cryogenic temperatures will be discussed from a component and systems point of view.

  6. Cryogenically Cooled Field Effect Transistors for Low-Noise Systems

    NASA Technical Reports Server (NTRS)

    Wollack, Edward J.

    2002-01-01

    Recent tends in the design, fabrication and use of High-Electron-Mobility-Transistors (HEMT) in low noise amplifiers are reviewed. Systems employing these devices have achieved the lowest system noise for wavelengths greater than three millimeters with relatively modest cryogenic cooling requirements in a variety of ground and space based applications. System requirements which arise in employing such devices in imaging applications are contrasted with other leading coherent detector candidates at microwave wavelengths. Fundamental and practical limitations which arise in the context of microwave application of field effect devices at cryogenic temperatures will be discussed from a component and systems point of view.

  7. Solar cooling system performance, Frenchman's Reef Hotel, Virgin Islands

    NASA Technical Reports Server (NTRS)

    Harber, H.

    1981-01-01

    The operational and thermal performance of a variety of solar systems are described. The Solar Cooling System was installed in a hotel at St. Thomas, U. S. Virgin Islands. The system consists of the evacuated glass tube collectors, two 2500 gallon tanks, pumps, computerized controller, a large solar optimized industrial sized lithium bromide absorption chiller, and associated plumbing. Solar heated water is pumped through the system to the designed public areas such as lobby, lounges, restaurant and hallways. Auxiliary heat is provided by steam and a heat exchanger to supplement the solar heat.

  8. Solar cooling system performance, Frenchman's Reef Hotel, Virgin Islands

    NASA Astrophysics Data System (ADS)

    Harber, H.

    1981-09-01

    The operational and thermal performance of a variety of solar systems are described. The Solar Cooling System was installed in a hotel at St. Thomas, U. S. Virgin Islands. The system consists of the evacuated glass tube collectors, two 2500 gallon tanks, pumps, computerized controller, a large solar optimized industrial sized lithium bromide absorption chiller, and associated plumbing. Solar heated water is pumped through the system to the designed public areas such as lobby, lounges, restaurant and hallways. Auxiliary heat is provided by steam and a heat exchanger to supplement the solar heat.

  9. Psychometric Properties of the Dyskinesia Identification System: Condensed User Scale (DISCUS).

    ERIC Educational Resources Information Center

    Sprague, Robert L.; And Others

    1989-01-01

    Individuals with developmental disability (n=400) were assessed with the "Dyskinesia Identification System: Condensed User Scale" (DISCUS), a 15-item tardive dyskinesia rating scale shortened from the "Dyskinesia Identification System-Coldwater." Based on interrater reliability, 2-week stability, and other analyses, DISCUS is recommended as the…

  10. Impact of ambient pressure on performance of desiccant cooling systems

    NASA Astrophysics Data System (ADS)

    Pesaran, A. A.

    1991-12-01

    The impact of ambient pressure on the performance of the ventilation cycle desiccant cooling system and its components was studied using computer simulations. The impact of ambient pressure depended on whether the system was designed for fixed-mass flow rate or fixed-volume flow rate operation. As ambient pressure decreased from 1.0 to 0.8 atm, the system thermal coefficient of performance increased by 8 pct. for both fixed-mass and fixed-volume flow rate, the cooling capacity of the system (in kW) was decreased by 14 pct. for the fixed-volume flow rate system and increased by 7 pct. for the fixed-mass flow rate system, the electric power requirements for the system with fixed-volume flow rate did not change, and the electric power requirement for the fixed-mass flow rate system increased by 44 pct. The overall coefficient of performance increased up to 5 pct. for the fixed-volume flow rate systems, and decreased up to 4 pct. for the fixed-mass flow rate system.

  11. Formation of Globular Clusters in Atomic-cooling Halos Via Rapid Gas Condensation and Fragmentation during the Epoch of Reionization

    NASA Astrophysics Data System (ADS)

    Kimm, Taysun; Cen, Renyue; Rosdahl, Joakim; Yi, Sukyoung K.

    2016-05-01

    We investigate the formation of metal-poor globular clusters (GCs) at the center of two dark matter halos with {M}{{halo}}˜ 4× {10}7 {M}ȯ at z\\gt 10 using cosmological radiation-hydrodynamics simulations. We find that very compact (≲1 pc) and massive (˜ 6× {10}5 {M}ȯ ) clusters form rapidly when pristine gas collapses isothermally with the aid of efficient Lyα emission during the transition from molecular-cooling halos to atomic-cooling halos. Because the local free-fall time of dense star-forming gas is very short (\\ll 1 {{Myr}}), a large fraction of the collapsed gas is turned into stars before stellar feedback processes blow out the gas and shut down star formation. Although the early stage of star formation is limited to a small region of the central star-forming disk, we find that the disk quickly fragments due to metal enrichment from supernovae. Sub-clusters formed in the fragmented clouds eventually merge with the main cluster at the center. The simulated clusters closely resemble the local GCs in mass and size but show a metallicity spread that is much wider than found in the local GCs. We discuss a role of pre-enrichment by Pop III and II stars as a potential solution to the latter issue. Although not without shortcomings, it is encouraging that a naive blind (not tuned) cosmological simulation presents a possible channel for the formation of at least some massive GCs.

  12. Method and system for providing cooling for turbine components

    DOEpatents

    Morgan, Victor John; Lacy, Benjamin Paul

    2016-08-16

    A system for providing cooling for a turbine component that includes an outer surface exposed to combustion gases is provided. A component base includes at least one fluid supply passage coupleable to a source of cooling fluid. At least one feed passage communicates with the at least one fluid supply passage. At least one delivery channel communicates with the at least one feed passage. At least one cover layer covers the at least one feed passage and the at least one delivery channel, defining at least in part the component outer surface. At least one discharge passage extends to the outer surface. A diffuser section is defined in at least one of the at least one delivery channel and the at least one discharge passage, such that a fluid channeled through the system is diffused prior to discharge adjacent the outer surface.

  13. Oil cooling system for a gas turbine engine

    NASA Technical Reports Server (NTRS)

    Coffinberry, G. A.; Kast, H. B. (Inventor)

    1977-01-01

    A gas turbine engine fuel delivery and control system is provided with means to recirculate all fuel in excess of fuel control requirements back to aircraft fuel tank, thereby increasing the fuel pump heat sink and decreasing the pump temperature rise without the addition of valving other than that normally employed. A fuel/oil heat exchanger and associated circuitry is provided to maintain the hot engine oil in heat exchange relationship with the cool engine fuel. Where anti-icing of the fuel filter is required, means are provided to maintain the fuel temperature entering the filter at or above a minimum level to prevent freezing thereof. Fluid circuitry is provided to route hot engine oil through a plurality of heat exchangers disposed within the system to provide for selective cooling of the oil.

  14. Optimizing process vacuum condensers

    SciTech Connect

    Lines, J.R.; Tice, D.W.

    1997-09-01

    Vacuum condensers play a critical role in supporting vacuum processing operations. Although they may appear similar to atmospheric units, vacuum condensers have their own special designs, considerations and installation needs. By adding vacuum condensers, precondensers and intercondensers, system cost efficiency can be optimized. Vacuum-condensing systems permit reclamation of high-value product by use of a precondenser, or reduce operating costs with intercondensers. A precondenser placed between the vacuum vessel and ejector system will recover valuable process vapors and reduce vapor load to an ejector system--minimizing the system`s capital and operating costs. Similarly, an intercondenser positioned between ejector stages can condense motive steam and process vapors and reduce vapor load to downstream ejectors as well as lower capital and operating costs. The paper describes vacuum condenser systems, types of vacuum condensers, shellside condensing, tubeside condensing, noncondensable gases, precondenser pressure drop, system interdependency, equipment installation, and equipment layout.

  15. The use of processes evaporation and condensation to provide a suitable operating environment of systems

    NASA Astrophysics Data System (ADS)

    Kolková, Zuzana; Holubčík, Michal; Malcho, Milan

    2016-06-01

    All electronic components which exhibit electrical conductor resistance, generates heat when electricity is passed (Joule - Lenz's Law). The generated heat is necessary to take into surrounding environment. To reduce the operating temperature of electronic components are used various types of cooling in electronic devices. The released heat is removed from the outside of the device in several ways, either alone or in combination. Intensification of cooling electronic components is in the use of heat transfer through phase changes. From the structural point of view it is important to create a cooling system which would be able to drain the waste heat converter for each mode of operation device. Another important criterion is the reliability of the cooling, and it is appropriate to choose cooling system, which would not contain moving elements. In this article, the issue tackled by the phase change in the heat pipe.

  16. Analysis of an evaporator-condenser-separated mechanical vapor compression system

    NASA Astrophysics Data System (ADS)

    Wu, Hong; Li, Yulong; Chen, Jiang

    2013-04-01

    An evaporator-condenser-separated mechanical vapor compression (MVC) system was presented. The better effect of descaling and antiscaling was obtained by the new system. This study focused on the method of thermodynamic analysis, and the energy and exergy flow diagrams were established by using the first and second law of thermodynamics analysis. The results show that the energy utilization rate is very high and the specific power consumption is low. Exergy analysis indicates that the exergy efficiency is low, and the largest exergy loss occurs within the evaporator -condenser and the compressor.

  17. Solar heating and cooling technical data and systems analysis

    NASA Technical Reports Server (NTRS)

    Christensen, D. L.

    1976-01-01

    The acquisition and processing of selected parametric data for inclusion in a computerized Data Base using the Marshall Information Retrieval and Data System (MIRADS) developed by NASA-MSFC is discussed. This data base provides extensive technical and socioeconomic information related to solar energy heating and cooling on a national scale. A broadly based research approach was used to assist in the support of program management and the application of a cost-effective program for solar energy development and demonstration.

  18. NASA's Marshall Space Flight Center Improves Cooling System Performance

    SciTech Connect

    2011-02-22

    National Aeronautics and Space Administration’s (NASA) Marshall Space Flight Center (MSFC) has a longstanding sustainability program that revolves around energy and water efficiency as well as environmental protection. MSFC identified a problematic cooling loop with six separate compressor heat exchangers and a history of poor efficiency. The facility engineering team at MSFC partnered with Flozone Services, Incorporated to implement a comprehensive water treatment platform to improve the overall efficiency of the system.

  19. Incremental cooling load determination for passive direct gain heating systems

    SciTech Connect

    Sullivan, P.W.; Mahone, D.; Fuller, W.; Gruber, J.; Kammerud, R.; Place, W.; Andersson, B.

    1981-05-01

    This paper examines the applicability of the National Association of Home Builders (NAHB) full load compressor hour method for predicting the cooling load increase in a residence, attributable to direct gain passive heating systems. The NAHB method predictions are compared with the results of 200 hour-by-hour simulations using BLAST and the two methods show reasonable agreement. The degree of agreement and the limitations of the NAHB method are discussed.

  20. Multistability in an optomechanical system with a two-component Bose-Einstein condensate

    SciTech Connect

    Dong Ying; Ye Jinwu; Pu Han

    2011-03-15

    We investigate a system consisting of a two-component Bose-Einstein condensate interacting dispersively with a Fabry-Perot optical cavity where the two components of the condensate are resonantly coupled to each other by another classical field. The key feature of this system is that the atomic motional degrees of freedom and the internal pseudospin degrees of freedom are coupled to the cavity field simultaneously, hence an effective spin-orbital coupling within the condensate is induced by the cavity. The interplay among the atomic center-of-mass motion, the atomic collective spin, and the cavity field leads to a strong nonlinearity, resulting in multistable behavior in both matter wave and light wave at the few-photon level.

  1. Finite-momentum condensate of magnetic excitons in a bilayer quantum Hall system

    NASA Astrophysics Data System (ADS)

    Doretto, R. L.; Morais Smith, C.; Caldeira, A. O.

    2012-07-01

    We study the bilayer quantum Hall system at total filling factor νT=1 within a bosonization formalism which allows us to approximately treat the magnetic exciton as a boson. We show that in the region where the distance between the two layers is comparable to the magnetic length, the ground state of the system can be seen as a finite-momentum condensate of magnetic excitons provided that the excitation spectrum is gapped. We analyze the stability of such a phase within the Bogoliubov approximation first assuming that only one momentum Q is macroscopically occupied and later we consider the same situation for two modes ±Q. We find strong evidences that a first-order quantum phase transition at small interlayer separation takes place from a zero-momentum condensate phase, which corresponds to Halperin 111 state, to a finite-momentum condensate of magnetic excitons.

  2. Solar heating and cooling system installed at Columbus, Ohio

    NASA Technical Reports Server (NTRS)

    1980-01-01

    The Solar Energy System was installed as a part of a new construction of a college building. The building will house classrooms and laboratories, administrative offices and three lecture halls. The Solar Energy System consists of 4,096 square feet (128 panels) Owens/Illinois Evacuated Glass Tube Collector Subsystem, and a 5,000 gallon steel tank below ground storage system. Hot water is circulated between the collectors and storage tank, passing through a water/lithium bromide absorption chiller to cool the building.

  3. Solar heating and cooling system installed at Columbus, Ohio

    NASA Astrophysics Data System (ADS)

    1980-09-01

    The Solar Energy System was installed as a part of a new construction of a college building. The building will house classrooms and laboratories, administrative offices and three lecture halls. The Solar Energy System consists of 4,096 square feet (128 panels) Owens/Illinois Evacuated Glass Tube Collector Subsystem, and a 5,000 gallon steel tank below ground storage system. Hot water is circulated between the collectors and storage tank, passing through a water/lithium bromide absorption chiller to cool the building.

  4. Keeping cool while planning a major cooling system modification for a large base-loaded power plant

    SciTech Connect

    Mallory, J.; Randels, R.; Penrose, J.; Ludovisi, D.

    2012-07-01

    This paper addresses vital considerations which need to be addressed to help ensure that the wisest approach is used for evaluating or modifying existing open or closed cycle cooling systems. (authors)

  5. WATER COOLED RETORT COVER

    DOEpatents

    Ash, W.J.; Pozzi, J.F.

    1962-05-01

    A retort cover is designed for use in the production of magnesium metal by the condensation of vaporized metal on a collecting surface. The cover includes a condensing surface, insulating means adjacent to the condensing surface, ind a water-cooled means for the insulating means. The irrangement of insulation and the cooling means permits the magnesium to be condensed at a high temperature and in massive nonpyrophoric form. (AEC)

  6. Evolutionary games of condensates in coupled birth-death processes

    NASA Astrophysics Data System (ADS)

    Weber, Markus F.; Knebel, Johannes; Krueger, Torben; Frey, Erwin

    2015-03-01

    Condensation phenomena occur in many systems, both in a classical and a quantum mechanical context. Typically, the entities that constitute a system collectively concentrate in one distinct state during condensation. For example, cooling of an equilibrated bosonic gas may lead to condensation into the quantum ground state. Notably, the mathematical theory of this Bose-Einstein condensation is not limited to quantum theory but was also successfully applied to condensation in random networks. In our work, we follow the opposite path. We apply the theory of evolutionary dynamics to describe condensation in a bosonic system that is driven and dissipative. It was shown that the system may condense into multiple quantum states, but into which states has remained elusive. We find that vanishing of relative entropy production determines these states. We illuminate the physical principles underlying the condensation and show that the condensates do not need to be static but may engage in ``evolutionary games'' with exchange of particles. On the mathematical level, the condensation is described by coupled birth-death processes. The generic structure of these processes implies that our results also apply to condensation in other systems, ranging from population biology to chemical kinetics.

  7. CFD analyses of natural circulation in the air-cooled reactor cavity cooling system

    SciTech Connect

    Hu, R.; Pointer, W. D.

    2013-07-01

    The Natural Convection Shutdown Heat Removal Test Facility (NSTF) is currently being built at Argonne National Laboratory, to evaluate the feasibility of the passive Reactor Cavity Cooling System (RCCS) for Next Generation Nuclear Plant (NGNP). CFD simulations have been applied to evaluate the NSTF and NGNP RCCS designs. However, previous simulations found that convergence was very difficult to achieve in simulating the complex natural circulation. To resolve the convergence issue and increase the confidence of the CFD simulation results, additional CFD simulations were conducted using a more detailed mesh and a different solution scheme. It is found that, with the use of coupled flow and coupled energy models, the convergence can be greatly improved. Furthermore, the effects of convection in the cavity and the effects of the uncertainty in solid surface emissivity are also investigated. (authors)

  8. Heat exchange and hydraulic resistance of compact laser mirror cooling systems

    NASA Astrophysics Data System (ADS)

    Shanin, Yu. I.; Shanin, O. I.

    2013-07-01

    The hydraulic resistance of cooling systems for laser mirrors and the heat exchange in them have been investigated experimentally. The data obtained have been generalized for several cooling systems with different porous elements.

  9. DEVELOP A CONCENTRATED SOLAR POWER-BASED THERMAL COOLING SYSTEM VIA SIMULATION AND EXPERIMENTAL STUDIES

    EPA Science Inventory

    A small scale CSP-based cooling system prototype (300W cooling capacity) and the system performance simulation tool will be developed as a proof of concept. Practical issues will be identified to improve our design.

  10. D0 Silicon Upgrad: D0 Silicon Cooling System

    SciTech Connect

    Squires, B.; /Fermilab

    1998-07-14

    The cooling system design is not complete. This paper lays out the general design and some of the design calculations that have been performed up to this date. Further refinement will be performed. This is especially true in the piping layout, piping insulation and detector manifold areas. The silicon detector is cooled by means of a coolant in the beryllium channels that also act as the primary supporting device for the silicon ladders and wedges. The coolant is water with ethylene glycol added as a freezing point depressant. The glycol concentration in the coolant is 30% by weight resulting in a freezing point of approximately -15 C. If the water/glycol is not sufficient for maintaining the desired detector temperature the concentration of the water/glycol may be changed or an alternative coolant may be used.

  11. POOL WATER TREATMENT AND COOLING SYSTEM DESCRIPTION DOCUMENT

    SciTech Connect

    V. King

    2000-06-19

    The Pool Water Treatment and Cooling System is located in the Waste Handling Building (WHB), and is comprised of various process subsystems designed to support waste handling operations. This system maintains the pool water temperature within an acceptable range, maintains water quality standards that support remote underwater operations and prevent corrosion, detects leakage from the pool liner, provides the capability to remove debris from the pool, controls the pool water level, and helps limit radiological exposure to personnel. The pool structure and liner, pool lighting, and the fuel staging racks in the pool are not within the scope of the Pool Water Treatment and Cooling System. Pool water temperature control is accomplished by circulating the pool water through heat exchangers. Adequate circulation and mixing of the pool water is provided to prevent localized thermal hotspots in the pool. Treatment of the pool water is accomplished by a water treatment system that circulates the pool water through filters, and ion exchange units. These water treatment units remove radioactive and non-radioactive particulate and dissolved solids from the water, thereby providing the water clarity needed to conduct waste handling operations. The system also controls pool water chemistry to prevent advanced corrosion of the pool liner, pool components, and fuel assemblies. Removal of radioactivity from the pool water contributes to the project ALARA (as low as is reasonably achievable) goals. A leak detection system is provided to detect and alarm leaks through the pool liner. The pool level control system monitors the water level to ensure that the minimum water level required for adequate radiological shielding is maintained. Through interface with a demineralized water system, adequate makeup is provided to compensate for loss of water inventory through evaporation and waste handling operations. Interface with the Site Radiological Monitoring System provides continuous

  12. System and method for cooling a super-conducting device

    SciTech Connect

    Bray, James William; Steinbach, Albert Eugene; Dawson, Richard Nils; Laskaris, Evangelos Trifon; Huang, Xianrul

    2008-01-08

    A system and method for cooling a superconductive rotor coil. The system comprises a rotatable shaft coupled to the superconductive rotor coil. The rotatable shaft may comprise an axial passageway extending through the rotatable shaft and a first passageway extending through a wall of the rotatable shaft to the axial passageway. The axial passageway and the first passageway are operable to convey a cryogenic fluid to the superconductive rotor coil through the wall of the rotatable shaft. A cryogenic transfer coupling may be provided to supply cryogenic fluid to the first passageway.

  13. System Study: Reactor Core Isolation Cooling 1998–2013

    SciTech Connect

    Schroeder, John Alton

    2015-01-31

    This report presents an unreliability evaluation of the reactor core isolation cooling (RCIC) system at 31 U.S. commercial boiling water reactors. Demand, run hours, and failure data from fiscal year 1998 through 2013 for selected components were obtained from the Institute of Nuclear Power Operations (INPO) Consolidated Events Database (ICES). The unreliability results are trended for the most recent 10-year period, while yearly estimates for system unreliability are provided for the entire active period. No statistically significant trends were identified in the RCIC results.

  14. System Study: Reactor Core Isolation Cooling 1998–2012

    SciTech Connect

    T. E. Wierman

    2013-10-01

    This report presents an unreliability evaluation of the reactor core isolation cooling (RCIC) system at 31 U.S. commercial boiling water reactors. Demand, run hours, and failure data from fiscal year 1998 through 2012 for selected components were obtained from the Equipment Performance and Information Exchange (EPIX). The unreliability results are trended for the most recent 10 year period while yearly estimates for system unreliability are provided for the entire active period. No statistically significant increasing trend was identified in the HPCI results. Statistically significant decreasing trends were identified for RCIC start-only and 8-hour trends.

  15. System Study: Reactor Core Isolation Cooling 1998-2014

    SciTech Connect

    Schroeder, John Alton

    2015-12-01

    This report presents an unreliability evaluation of the reactor core isolation cooling (RCIC) system at 31 U.S. commercial boiling water reactors. Demand, run hours, and failure data from fiscal year 1998 through 2014 for selected components were obtained from the Institute of Nuclear Power Operations (INPO) Consolidated Events Database (ICES). The unreliability results are trended for the most recent 10 year period, while yearly estimates for system unreliability are provided for the entire active period. No statistically significant trends were identified in the RCIC results.

  16. Computer Simulation Performed for Columbia Project Cooling System

    NASA Technical Reports Server (NTRS)

    Ahmad, Jasim

    2005-01-01

    This demo shows a high-fidelity simulation of the air flow in the main computer room housing the Columbia (10,024 intel titanium processors) system. The simulation asseses the performance of the cooling system and identified deficiencies, and recommended modifications to eliminate them. It used two in house software packages on NAS supercomputers: Chimera Grid tools to generate a geometric model of the computer room, OVERFLOW-2 code for fluid and thermal simulation. This state-of-the-art technology can be easily extended to provide a general capability for air flow analyses on any modern computer room. Columbia_CFD_black.tiff

  17. Modular cogeneration in district heating and cooling systems

    SciTech Connect

    Andrews, J.W.; Aalto, P.; Gleason, T.C.J.; Skalafuris, A.J.

    1987-12-01

    The use of prepackaged cogeneration systems of modular size (100 kWe - 10 MWe) in conjunction with district heating and cooling is proposed as a way to enhance the energy conservation potential of both cogeneration and district energy systems. This report examines the technical and institutional aspects of this marriage of technologies, and develops a research agenda whose goal is to define this potential use of cogeneration more accurately and to develop the generic technology base needed to bring it to actuality. 11 refs.

  18. Heat pipe radiation cooling of advanced hypersonic propulsion system components

    NASA Technical Reports Server (NTRS)

    Martin, R. A.; Keddy, M.; Merrigan, M. A.; Silverstein, C. C.

    1991-01-01

    Heat transfer, heat pipe, and system studies were performed to assess the newly proposed heat pipe radiation cooling (HPRC) concept. With an HPRC system, heat is removed from the ramburner and nozzle of a hypersonic aircraft engine by a surrounding, high-temperature, heat pipe nacelle structure, transported to nearby external surfaces, and rejected to the environment by thermal radiation. With HPRC, the Mach number range available for using hydrocarbon fuels for aircraft operation extends into the Mach 4 to Mach 6 range, up from the current limit of about Mach 4. Heat transfer studies using a newly developed HPRC computer code determine cooling system and ramburner and nozzle temperatures, heat loads, and weights for a representative combined-cycle engine cruising at Mach 5 at 80,000 ft altitude. Heat pipe heat transport calculations, using the Los Alamos code HTPIPE, reveal that adequate heat trasport capability is available using molybdenum-lithium heat pipe technology. Results show that the HPRC system radiator area is limited in size to the ramburner-nozzle region of the engine nacelle; reasonable system weights are expected; hot section temperatures are consistent with advanced structural materials development goals; and system impact on engine performance is minimal.

  19. A system for quantifying the cooling effectiveness of bicycle helmets.

    PubMed

    Reid, J; Wang, E L

    2000-08-01

    This article describes the design and development of a system that is capable of quantifying the thermal comfort of bicycle helmets. The motivation for the development of the system stems from the desire both to increase helmet use and to provide the designer with a quantitative method of evaluating the thermal comfort of a helmet. The system consists of a heated mannequin head form, a heated reference sphere, a small wind tunnel, and a data acquisition system. Both the head form and the reference sphere were instrumented with thermocouples. The system is capable of simulating riding speeds ranging from 4.5-15.5 m/s. A cooling effectiveness, C1, that is independent of both ambient conditions and wind velocity is defined as a measure of how well the helmet ventilates as compared to the reference sphere. The system was validated by testing six commercially available bicycle helmets manufactured between approximately 1992 and 1998. PMID:11036573

  20. Active cooling for downhole instrumentation: Preliminary analysis and system selection

    SciTech Connect

    Bennett, G.A.

    1988-03-01

    A feasibility study and a series of preliminary designs and analyses were done to identify candidate processes or cycles for use in active cooling systems for downhole electronic instruments. A matrix of energy types and their possible combinations was developed and the energy conversion process for each pari was identified. The feasibility study revealed conventional as well as unconventional processes and possible refrigerants and identified parameters needing further clarifications. A conceptual design or series od oesigns for each system was formulated and a preliminary analysis of each design was completed. The resulting coefficient of performance for each system was compared with the Carnot COP and all systems were ranked by decreasing COP. The system showing the best combination of COP, exchangeability to other operating conditions, failure mode, and system serviceability is chosen for use as a downhole refrigerator. 85 refs., 48 figs., 33 tabs.

  1. Laminated turbine vane design and fabrication. [utilizing film cooling as a cooling system

    NASA Technical Reports Server (NTRS)

    Hess, W. G.

    1979-01-01

    A turbine vane and associated endwalls designed for advanced gas turbine engine conditions are described. The vane design combines the methods of convection cooling and selective areas of full coverage film cooling. The film cooling technique is utilized on the leading edge, pressure side, and endwall regions. The turbine vane involves the fabrication of airfoils from a stack of laminates with cooling passages photoetched on the surface. Cold flow calibration tests, a thermal analysis, and a stress analysis were performed on the turbine vanes.

  2. Cooling system of an internal combustion engine having a turbo-charger

    SciTech Connect

    Hasegawa, M.; Fukuda, T.

    1986-09-02

    A cooling system of an internal combustion engine is described having a turbo-charger, comprising a cooling water circulation passageway filled with cooling water for cooling the engine including at least a cylinder head cooling portion, a cooling water circulation passageway for cooling the turbo-charger including a turbo-charger cooling portion, and means for supplying a part of the engine cooling water to the turbo-charger cooling water ciruclation passageway and returning it from there to the engine cooling water cirulation passageway, characterized in that the turbo-charger cooling portion is positioned at the same level or higher than the cylinder head cooling portion of the engine, the turbo-charger cooling water circulation passageway includes a water volume positioned at a level higher than the turbo-charger cooling portion. The volume is connected to a cooling water reservoir tank via a pressure relief valve which is opened when pressure in the volume exceeds a predetermined value to supply cooling water to the volume.

  3. Phase diagrams of a condensed decane-eicosane-cyclododecane system

    NASA Astrophysics Data System (ADS)

    Garkushin, I. K.; Kolyado, A. V.; Shamitov, A. A.

    2016-05-01

    An n-eicosane-cyclododecane- n-decane system related to eutectic-type systems is investigated by means of differential thermal analysis. The eutectic alloy with melting point of-33.8°C contains 2.8 wt % of n-eicosane, 89.2 wt % of n-decane, and 8.0 wt % of cyclododecane.

  4. A gas-cooled reactor surface power system

    NASA Astrophysics Data System (ADS)

    Lipinski, Ronald J.; Wright, Steven A.; Lenard, Roger X.; Harms, Gary A.

    1999-01-01

    A human outpost on Mars requires plentiful power to assure survival of the astronauts. Anywhere from 50 to 500 kW of electric power (kWe) will be needed, depending on the number of astronauts, level of scientific activity, and life-cycle closure desired. This paper describes a 250-kWe power system based on a gas-cooled nuclear reactor with a recuperated closed Brayton cycle conversion system. The design draws upon the extensive data and engineering experience developed under the various high-temperature gas cooled reactor programs and under the SP-100 program. The reactor core is similar in power and size to the research reactors found on numerous university campuses. The fuel is uranium nitride clad in Nb1%Zr, which has been extensively tested under the SP-100 program. The fuel rods are arranged in a hexagonal array within a BeO block. The BeO softens the spectrum, allowing better use of the fuel and stabilizing the geometry against deformation during impact or other loadings. The system has a negative temperature feedback coefficient so that the power level will automatically follow a variable load without the need for continuous adjustment of control elements. Waste heat is removed by an air-cooled heat exchanger using cold Martian air. The amount of radioactivity in the reactor at launch is very small (less than a Curie, and about equal to a truckload of uranium ore). The system will need to be engineered so that criticality can not occur for any launch accident. This system is also adaptable for electric propulsion or life-support during transit to and from Mars.

  5. A Gas-Cooled Reactor Surface Power System

    SciTech Connect

    Harms, G.A.; Lenard, R.X.; Lipinski, R.J.; Wright, S.A.

    1998-11-09

    A human outpost on Mars requires plentiful power to assure survival of the astronauts. Anywhere from 50 to 500 kW of electric power (kWe) will be needed, depending on the number of astronauts, level of scientific activity, and life- cycle closure desired. This paper describes a 250-kWe power system based on a gas-cooled nuclear reactor with a recuperated closed Brayton cycle conversion system. The design draws upon the extensive data and engineering experience developed under the various high-temperature gas cooled reactor programs and under the SP-100 program. The reactor core is similar in power and size to the research reactors found on numerous university campuses. The fuel is uranium nitide clad in Nb 1 %Zr, which has been extensively tested under the SP-I 00 program The fiel rods are arranged in a hexagonal array within a BeO block. The BeO softens the spectrum, allowing better use of the fbel and stabilizing the geometty against deformation during impact or other loadings. The system has a negative temperature feedback coefficient so that the power level will automatically follow a variable load without the need for continuous adjustment of control elements. Waste heat is removed by an air-cooled heat exchanger using cold Martian air. The amount of radioactivity in the reactor at launch is very small (less than a Curie, and about equal to a truckload of uranium ore). The system will need to be engineered so that criticality cannot occur for any launch accident. This system is also adaptable for electric propulsion or life-support during transit to and from Mars.

  6. A gas-cooled reactor surface power system

    SciTech Connect

    Lipinski, R.J.; Wright, S.A.; Lenard, R.X.; Harms, G.A.

    1999-01-01

    A human outpost on Mars requires plentiful power to assure survival of the astronauts. Anywhere from 50 to 500 kW of electric power (kWe) will be needed, depending on the number of astronauts, level of scientific activity, and life-cycle closure desired. This paper describes a 250-kWe power system based on a gas-cooled nuclear reactor with a recuperated closed Brayton cycle conversion system. The design draws upon the extensive data and engineering experience developed under the various high-temperature gas cooled reactor programs and under the SP-100 program. The reactor core is similar in power and size to the research reactors found on numerous university campuses. The fuel is uranium nitride clad in Nb1{percent}Zr, which has been extensively tested under the SP-100 program. The fuel rods are arranged in a hexagonal array within a BeO block. The BeO softens the spectrum, allowing better use of the fuel and stabilizing the geometry against deformation during impact or other loadings. The system has a negative temperature feedback coefficient so that the power level will automatically follow a variable load without the need for continuous adjustment of control elements. Waste heat is removed by an air-cooled heat exchanger using cold Martian air. The amount of radioactivity in the reactor at launch is very small (less than a Curie, and about equal to a truckload of uranium ore). The system will need to be engineered so that criticality can not occur for any launch accident. This system is also adaptable for electric propulsion or life-support during transit to and from Mars. {copyright} {ital 1999 American Institute of Physics.}

  7. A gas-cooled reactor surface power system

    SciTech Connect

    Lipinski, Ronald J.; Wright, Steven A.; Lenard, Roger X.; Harms, Gary A.

    1999-01-22

    A human outpost on Mars requires plentiful power to assure survival of the astronauts. Anywhere from 50 to 500 kW of electric power (kWe) will be needed, depending on the number of astronauts, level of scientific activity, and life-cycle closure desired. This paper describes a 250-kWe power system based on a gas-cooled nuclear reactor with a recuperated closed Brayton cycle conversion system. The design draws upon the extensive data and engineering experience developed under the various high-temperature gas cooled reactor programs and under the SP-100 program. The reactor core is similar in power and size to the research reactors found on numerous university campuses. The fuel is uranium nitride clad in Nb1%Zr, which has been extensively tested under the SP-100 program. The fuel rods are arranged in a hexagonal array within a BeO block. The BeO softens the spectrum, allowing better use of the fuel and stabilizing the geometry against deformation during impact or other loadings. The system has a negative temperature feedback coefficient so that the power level will automatically follow a variable load without the need for continuous adjustment of control elements. Waste heat is removed by an air-cooled heat exchanger using cold Martian air. The amount of radioactivity in the reactor at launch is very small (less than a Curie, and about equal to a truckload of uranium ore). The system will need to be engineered so that criticality can not occur for any launch accident. This system is also adaptable for electric propulsion or life-support during transit to and from Mars.

  8. Air heating system

    DOEpatents

    Primeau, John J.

    1983-03-01

    A self-starting, fuel-fired, air heating system including a vapor generator, a turbine, and a condenser connected in a closed circuit such that the vapor output from the vapor generator is conducted to the turbine and then to the condenser where it is condensed for return to the vapor generator. The turbine drives an air blower which passes air over the condenser for cooling the condenser. Also, a condensate pump is driven by the turbine. The disclosure is particularly concerned with the provision of heat exchanger and circuitry for cooling the condensed fluid output from the pump prior to its return to the vapor generator.

  9. Absorption heat pump in heating and cooling systems of buildings

    NASA Astrophysics Data System (ADS)

    Aho, I.

    This report focuses on the operation and applicability of absorption heat pumps (AHP) in building heating and cooling systems. Examples are presented on heating systems of residential buildings and a heating/cooling system of an office building. Despite the limitations of present AHP technology the examples assume AHPs which produce heat at an appropriate temperature level for each application. According to the calculations the primary energy saving potential of AHPs in building specific heat production is 20 to 40 percent. For AHPs coupled with district heating systems the primary energy saving potential can not be unambiguously defined because it is influenced by the production form of district heat, the influence of district heat demand on power generation etc. For the time being economical aspects limit the application potential of AHPs. The profitability of AHP investments is quite poor because of present energy prices, the price ratio of different energy forms and the high investment cost of AHP-systems. The environmental impact of AHPs depend on the fuel used in the generator. Using fuel oil or gas will decrease sulphur and particle emissions but might increase the emissions of NO(x) and hydrocarbons because of the smaller size of combustion units. CFC-emissions will be decreased because AHPs apply alternative refrigerants.

  10. Advanced heat pump cycle for district heating and cooling systems

    SciTech Connect

    Radermacher, R.

    1991-07-01

    A bread board heat pump was designed and built to test the performance of a vapor compression heat pump with two stage ammonia-water solution circuits. The design was updated based on the experience gained with the single stage version of this heat pump. A major improvement was obtained by eliminating the rectifier. The new scheme was first investigated by computer simulation and then incorporated in the experimental setup. Water balance in the high and low temperature circuits is now maintained by bleeding up to 2.5% of the weak solution flow from one solution circuit to the other. The advantages of this scheme are reduced first cost, simplified design and control, 20--30% improvement in cooling coefficient of performance and 10--15% increase in cooling capacity as compared to the cycle with a rectifier. Coefficients of performance in the range of 0.84 to 1.03 were obtained experimentally for a temperature lift of 100-K. The pressure ratios encountered were in the range of 7.6 to 9.9, which are 35 to 50% of the pressure ratio expected for a conventional heat pump. Thus the results demonstrate that high temperature lifts can be achieved at pressure ratios which are less than half as large as for conventional systems. The cooling capacities were in the range of 2.79 to 4.21 kW. 13 refs., 5 figs., 2 tabs.

  11. Dry coolers and air-condensing units (Review)

    NASA Astrophysics Data System (ADS)

    Milman, O. O.; Anan'ev, P. A.

    2016-03-01

    The analysis of factors affecting the growth of shortage of freshwater is performed. The state and dynamics of the global market of dry coolers used at electric power plants are investigated. Substantial increase in number and maximum capacity of air-cooled condensers, which have been put into operation in the world in recent years, are noted. The key reasons facilitating the choice of developers of the dry coolers, in particular the independence of the location of thermal power plant from water sources, are enumerated. The main steam turbine heat removal schemes using air cooling are considered, their comparison of thermal efficiency is assessed, and the change of three important parameters, such as surface area of heat transfer, condensate pump flow, and pressure losses in the steam exhaust system, are estimated. It is shown that the most effective is the scheme of direct steam condensation in the heat-exchange tubes, but other schemes also have certain advantages. The air-cooling efficiency may be enhanced much more by using an air-cooling hybrid system: a combination of dry and wet cooling. The basic applied constructive solutions are shown: the arrangement of heat-exchange modules and the types of fans. The optimal mounting design of a fully shopassembled cooling system for heat-exchange modules is represented. Different types of heat-exchange tubes ribbing that take into account the operational features of cooling systems are shown. Heat transfer coefficients of the plants from different manufacturers are compared, and the main reasons for its decline are named. When using evaporative air cooling, it is possible to improve the efficiency of air-cooling units. The factors affecting the faultless performance of dry coolers (DC) and air-condensing units (ACU) and the ways of their elimination are described. A high velocity wind forcing reduces the efficiency of cooling systems and creates preconditions for the development of wind-driven devices. It is noted that

  12. Review of microclimate cooling systems in the chemical, biological, radiological environment

    SciTech Connect

    Derion, T.; Pozos, R.S.

    1993-09-22

    Soldiers may work in hot environments and under conditions posing a biological, chemical, or nuclear threat. Chemical protective overgarments are worn to prevent contact with toxins; however, they prevent dissipation of body heat. This review addresses the effectiveness of microclimate cooling systems in alleviating thermal strain in personnel encapsulated in protective overgarments during exertion in the heat. Air, liquid, and passive ice cooling systems are primarily reviewed, but other methodologies are also discussed. Air cooling can increase tolerance time fourfold, but high ambient temperature air cooling may be dangerous. Liquid cooling is effective in reducing heat strain at light to moderate work loads and is beneficial when applied to the thighs during lower-body exercise. Overcooling and discomfort can occur with a liquid-cooled system due to cutaneous vasoconstriction. Liquid-cooled systems are heavy, require excessive maintenance, and tube compression can result in interrupted coolant flow. Air cooling is inefficient compared to liquid cooling because of air's lower specific heat. Ice cooling may only be suitable for short-term work and is generally less effective than either air or liquid cooling although the wearer can move about untethered. The best cooling system design approach may he indicated by consideration of the unique cooling needs of personnel performing specific tasks in various environments. Microclimate cooling CBR Environment.

  13. Laser cooling of a high-temperature oscillator by a three-level system

    NASA Astrophysics Data System (ADS)

    Lau, Hoi-Kwan; Plenio, Martin B.

    2016-08-01

    We study the laser cooling of a mechanical oscillator through the coupling with a dissipative three-level system. Under a background temperature beyond the Lamb-Dicke regime, we extend the standard cooling analysis by separately studying the classical motion and the quantum dynamics of the oscillator. In ladder-system cooling, the cooling rate degrades by orders of magnitude at large classical motion. This phenomenon causes a critical transition of the final temperature at a hot background. In stark contrast, electromagnetic-induced-transparency (EIT) cooling with a Λ system produces significant negative cooling rate at high motional excitation. At steady state, the oscillator could exhibit both cooling and lasing behaviors. We argue that a successful EIT cooling requires either a poor quality oscillator to suppress the lasing effect, or terminating the cooling process at a transient stage.

  14. Freezing Drizzle Formation in Stably Stratified Layer Clouds: The Role of Radiative Cooling of Cloud Droplets, Cloud Condensation Nuclei, and Ice Initiation.

    NASA Astrophysics Data System (ADS)

    Rasmussen, Roy M.; Geresdi, István; Thompson, Greg; Manning, Kevin; Karplus, Eli

    2002-02-01

    This study evaluates the role of 1) low cloud condensation nuclei (CCN) conditions and 2) preferred radiative cooling of large cloud drops as compared to small cloud drops, on cloud droplet spectral broadening and subsequent freezing drizzle formation in stably stratified layer clouds. In addition, the sensitivity of freezing drizzle formation to ice initiation is evaluated. The evaluation is performed by simulating cloud formation over a two-dimensional idealized mountain using a detailed microphysical scheme implemented into the National Center for Atmospheric Research-Pennsylvania State University Mesoscale Model version 5. The height and width of the two-dimensional mountain were designed to produce an updraft pattern with extent and magnitude similar to documented freezing drizzle cases. The results of the model simulations were compared to observations and good agreement was found.The key results of this study are 1) low CCN concentrations lead to rapid formation of freezing drizzle. This occurs due to the broad cloud droplet size distribution formed throughout the cloud in this situation, allowing for rapid broadening of the spectra to the point at which the collision-coalescence process is initiated. 2) Continental clouds can produce freezing drizzle given sufficient depth and time. 3) Radiative cooling of the cloud droplets near cloud top can be effective in broadening an initially continental droplet spectrum toward that of a maritime cloud droplet size distribution. 4) Any mechanism that only broadens the cloud droplet spectra near cloud top, such as radiative cooling, may not act over a sufficiently broad volume of the cloud to produce significant amounts of freezing drizzle. 5) Low ice-crystal concentrations (<0.08 L1) in the region of freezing drizzle formation is a necessary condition for drizzle formation (from both model and observations). 6) Ice nuclei depletion is a necessary requirement for the formation of freezing drizzle. 7) The maximum cloud

  15. System design package for the solar heating and cooling central data processing system

    NASA Technical Reports Server (NTRS)

    1978-01-01

    The central data processing system provides the resources required to assess the performance of solar heating and cooling systems installed at remote sites. These sites consist of residential, commercial, government, and educational types of buildings, and the solar heating and cooling systems can be hot-water, space heating, cooling, and combinations of these. The instrumentation data associated with these systems will vary according to the application and must be collected, processed, and presented in a form which supports continuity of performance evaluation across all applications. Overall software system requirements were established for use in the central integration facility which transforms raw data collected at remote sites into performance evaluation information for assessing the performance of solar heating and cooling systems.

  16. Modification of the Core Cooling System of TRIGA 2000 Reactor

    SciTech Connect

    Umar, Efrizon; Fiantini, Rosalina

    2010-06-22

    To accomplish safety requirements, a set of actions has to be performed following the recommendations of the IAEA safety series 35 applied to research reactor. Such actions are considered in modernization of the old system, improving the core cooling system and safety evaluations. Due to the complexity of the process and the difficulty in putting the apparatus in the reactor core, analytical and experimental study on the determination of flow and temperature distribution in the whole coolant channel are difficult to be done. In the present work, a numerical study of flow and temperature distribution in the coolant channel of TRIGA 2000 has been carried out using CFD package. For this study, simulations were carried out on 3-D tested model. The model consists of the reactor tank, thermal and thermalizing column, reflector, rotary specimen rack, chimney, fuel element, primary pipe, diffuser, beam tube and a part of the core are constructed by 1.50 million unstructured tetrahedral cell elements. The results show that for the initial condition (116 fuel elements in the core) and for the inlet temperature of 24 deg. C and the primary velocity of 5.6 m/s, there no boiling phenomena occur in the coolant channel. Due to this result, it is now possible to improve the core cooling system of TRIGA 2000 reactor. Meanwhile, forced flow from the diffuser system only affected the flow pattern in the outside of chimney and put on a small effect to the fluid flow's velocity in the inside of chimney.

  17. Modification of the Core Cooling System of TRIGA 2000 Reactor

    NASA Astrophysics Data System (ADS)

    Umar, Efrizon; Fiantini, Rosalina

    2010-06-01

    To accomplish safety requirements, a set of actions has to be performed following the recommendations of the IAEA safety series 35 applied to research reactor. Such actions are considered in modernization of the old system, improving the core cooling system and safety evaluations. Due to the complexity of the process and the difficulty in putting the apparatus in the reactor core, analytical and experimental study on the determination of flow and temperature distribution in the whole coolant channel are difficult to be done. In the present work, a numerical study of flow and temperature distribution in the coolant channel of TRIGA 2000 has been carried out using CFD package. For this study, simulations were carried out on 3-D tested model. The model consists of the reactor tank, thermal and thermalizing column, reflector, rotary specimen rack, chimney, fuel element, primary pipe, diffuser, beam tube and a part of the core are constructed by 1.50 million unstructured tetrahedral cell elements. The results show that for the initial condition (116 fuel elements in the core) and for the inlet temperature of 24°C and the primary velocity of 5.6 m/s, there no boiling phenomena occur in the coolant channel. Due to this result, it is now possible to improve the core cooling system of TRIGA 2000 reactor. Meanwhile, forced flow from the diffuser system only affected the flow pattern in the outside of chimney and put on a small effect to the fluid flow's velocity in the inside of chimney.

  18. Pilot-scale cooling tower to evaluate corrosion, scaling, and biofouling control strategies for cooling system makeup water.

    PubMed

    Chien, S H; Hsieh, M K; Li, H; Monnell, J; Dzombak, D; Vidic, R

    2012-02-01

    Pilot-scale cooling towers can be used to evaluate corrosion, scaling, and biofouling control strategies when using particular cooling system makeup water and particular operating conditions. To study the potential for using a number of different impaired waters as makeup water, a pilot-scale system capable of generating 27,000 kJ∕h heat load and maintaining recirculating water flow with a Reynolds number of 1.92 × 10(4) was designed to study these critical processes under conditions that are similar to full-scale systems. The pilot-scale cooling tower was equipped with an automatic makeup water control system, automatic blowdown control system, semi-automatic biocide feeding system, and corrosion, scaling, and biofouling monitoring systems. Observed operational data revealed that the major operating parameters, including temperature change (6.6 °C), cycles of concentration (N = 4.6), water flow velocity (0.66 m∕s), and air mass velocity (3660 kg∕h m(2)), were controlled quite well for an extended period of time (up to 2 months). Overall, the performance of the pilot-scale cooling towers using treated municipal wastewater was shown to be suitable to study critical processes (corrosion, scaling, biofouling) and evaluate cooling water management strategies for makeup waters of complex quality. PMID:22380105

  19. Condenser on-line leak-detection system development. Final report

    SciTech Connect

    Not Available

    1991-11-01

    Condenser tube leaks have been the number one source of impurities in most utility steam cycles. The impurities lead to corrosion of feedwater systems, boilers, and turbines. EPRI recommends sodium in the condensate be less than 3 ppb, which means less than one gallon leakage per day in some cases. The location of leaks requires isolation of the condenser water box and is costly because of power reduction. On-line detection using tracer can cut down the isolation time and, therefore, offers cost advantages to utilities. The on-line leak detection technique utilizes the concepts developed by EPRI for ``targeted chlorination``. Sulfur hexafluoride (SF{sub 6}), helium gases, and perfluorocarbon liquid were considered as tracers. Laboratory studies were conducted to evaluate the practicability of injecting water with dissolved SF{sub 6} gas, SF{sub 6} bubbles, and dissolved SF{sub 6} gas in perfluorocarbon liquid. Both static and dynamic tests were conducted in a condenser model. It was determined that water entrained with SF{sub 6} bubbles offered the most practical method of injection, followed by dissolved SF{sub 6} gas in perfluorocarbon. A conceptual design was developed that utilizes a water lance, a swivel arrangement in the waterbox manhole cover, a tracer targeting and mixing system, and a tracer gas detection system at the air ejector exhaust. A successful demonstration of targeted leak detection using a waterjet lance with SF{sub 6} was conducted at Carolina Power & Light Company`s Asheville Steam Electric Station Unit 1. A measurable artificially created leak was detected and located using this system with the condenser on-line. 2 refs., 39 figs., 6 tabs.

  20. Simulation of homogeneous condensation of small polyatomic systems in high pressure supersonic nozzle flows using Bhatnagar-Gross-Krook model.

    PubMed

    Kumar, Rakesh; Levin, Deborah A

    2011-03-28

    In the present work, we have simulated the homogeneous condensation of carbon dioxide and ethanol using the Bhatnagar-Gross-Krook based approach. In an earlier work of Gallagher-Rogers et al. [J. Thermophys. Heat Transfer 22, 695 (2008)], it was found that it was not possible to simulate condensation experiments of Wegener et al. [Phys. Fluids 15, 1869 (1972)] using the direct simulation Monte Carlo method. Therefore, in this work, we have used the statistical Bhatnagar-Gross-Krook approach, which was found to be numerically more efficient than direct simulation Monte Carlo method in our previous studies [Kumar et al., AIAA J. 48, 1531 (2010)], to model homogeneous condensation of two small polyatomic systems, carbon dioxide and ethanol. A new weighting scheme is developed in the Bhatnagar-Gross-Krook framework to reduce the computational load associated with the study of homogeneous condensation flows. The solutions obtained by the use of the new scheme are compared with those obtained by the baseline Bhatnagar-Gross-Krook condensation model (without the species weighting scheme) for the condensing flow of carbon dioxide in the stagnation pressure range of 1-5 bars. Use of the new weighting scheme in the present work makes the simulation of homogeneous condensation of ethanol possible. We obtain good agreement between our simulated predictions for homogeneous condensation of ethanol and experiments in terms of the point of condensation onset and the distribution of mass fraction of ethanol condensed along the nozzle centerline. PMID:21456688

  1. Simulation of homogeneous condensation of small polyatomic systems in high pressure supersonic nozzle flows using Bhatnagar-Gross-Krook model

    NASA Astrophysics Data System (ADS)

    Kumar, Rakesh; Levin, Deborah A.

    2011-03-01

    In the present work, we have simulated the homogeneous condensation of carbon dioxide and ethanol using the Bhatnagar-Gross-Krook based approach. In an earlier work of Gallagher-Rogers et al. [J. Thermophys. Heat Transfer 22, 695 (2008)], it was found that it was not possible to simulate condensation experiments of Wegener et al. [Phys. Fluids 15, 1869 (1972)] using the direct simulation Monte Carlo method. Therefore, in this work, we have used the statistical Bhatnagar-Gross-Krook approach, which was found to be numerically more efficient than direct simulation Monte Carlo method in our previous studies [Kumar et al., AIAA J. 48, 1531 (2010)], to model homogeneous condensation of two small polyatomic systems, carbon dioxide and ethanol. A new weighting scheme is developed in the Bhatnagar-Gross-Krook framework to reduce the computational load associated with the study of homogeneous condensation flows. The solutions obtained by the use of the new scheme are compared with those obtained by the baseline Bhatnagar-Gross-Krook condensation model (without the species weighting scheme) for the condensing flow of carbon dioxide in the stagnation pressure range of 1-5 bars. Use of the new weighting scheme in the present work makes the simulation of homogeneous condensation of ethanol possible. We obtain good agreement between our simulated predictions for homogeneous condensation of ethanol and experiments in terms of the point of condensation onset and the distribution of mass fraction of ethanol condensed along the nozzle centerline.

  2. Development of liquid-film tracking models for analysis of AP-600 passive containment cooling system

    SciTech Connect

    Sun, J.G.; Sha, W.T.; Chen, Y.S.

    1993-10-01

    The AP-600, an advanced pressurized water reactor, utilizes a passive containment cooling system (PCCS) to remove heat released inside the containment vessel following postulated design-base accidents (DBAS) such as a main-steam-line break or loss-of-coolant accident. The containment vessel consists of a vertical cylindrical shell and is capped at both top and bottom by a dome that is also a body of revolution with a meridian cross section in the shape of a semiellipse with a horizontal major axis. During a DBA, heat released to the interior of the steel containment vessel is removed by evaporation of a continuously flowing thin liquid film on the outside surface of the vessel, thus lowering the temperature of the steel vessel wall so that steam condenses on its inside surface. The external liquid film is formed by flooding water at top of the ellipsoidal dome. Evaporation of the falling liquid film is enhanced by buoyancy-driven flows of moist air in an annular space outside the steel containment vessel. To ensure PCCS performance, it is necessary to predict both the evaporating film on the outside surface of the vessel and the condensate film on its inside. To this end, two liquid-film tracking models for time-dependent flows (a simplified model and a comprehensive model) have been developed and implemented in the COMMIX code. COMMIX is a general-purpose, time-dependent, multidimensional computer code for thermal hydraulic analysis of single- or multicomponent engineering systems. It solves a system of conservation equations of continuities for up to six species, mixture momentum, and mixture energy, and a k-{epsilon} two-equation turbulent model. A unique feature of the COMMIX code is its porous-media formulation, which represents the first unified approach to thermal-hydraulic analysis. The tracking models discussed in this report compute the liquid-film thickness, its mean velocity, and its temperature on both sides of the steel containment vessel.

  3. The Helium Cooling System and Cold Mass Support System for theMICE Coupling Solenoid

    SciTech Connect

    Wang, L.; Wu, H.; Li, L.K.; Green, M.A.; Liu, C.S.; Li, L.Y.; Jia, L.X.; Virostek, S.P.

    2007-08-27

    The MICE cooling channel consists of alternating threeabsorber focus coil module (AFC) and two RF coupling coil module (RFCC)where the process of muon cooling and reacceleration occurs. The RFCCmodule comprises a superconducting coupling solenoid mounted around fourconventional conducting 201.25 MHz closed RF cavities and producing up to2.2T magnetic field on the centerline. The coupling coil magnetic fieldis to produce a low muon beam beta function in order to keep the beamwithin the RF cavities. The magnet is to be built using commercialniobium titanium MRI conductors and cooled by pulse tube coolers thatproduce 1.5 W of cooling capacity at 4.2 K each. A self-centering supportsystem is applied for the coupling magnet cold mass support, which isdesigned to carry a longitudinal force up to 500 kN. This report willdescribe the updated design for the MICE coupling magnet. The cold masssupport system and helium cooling system are discussed indetail.

  4. System and method for cooling a superconducting rotary machine

    SciTech Connect

    Ackermann, Robert Adolf; Laskaris, Evangelos Trifon; Huang, Xianrui; Bray, James William

    2011-08-09

    A system for cooling a superconducting rotary machine includes a plurality of sealed siphon tubes disposed in balanced locations around a rotor adjacent to a superconducting coil. Each of the sealed siphon tubes includes a tubular body and a heat transfer medium disposed in the tubular body that undergoes a phase change during operation of the machine to extract heat from the superconducting coil. A siphon heat exchanger is thermally coupled to the siphon tubes for extracting heat from the siphon tubes during operation of the machine.

  5. Solar heating and cooling technical data and systems analysis

    NASA Technical Reports Server (NTRS)

    Christensen, D. L.

    1976-01-01

    The accomplishments of a project to study solar heating and air conditioning are outlined. Presentation materials (data packages, slides, charts, and visual aids) were developed. Bibliographies and source materials on materials and coatings, solar water heaters, systems analysis computer models, solar collectors and solar projects were developed. Detailed MIRADS computer formats for primary data parameters were developed and updated. The following data were included: climatic, architectural, topography, heating and cooling equipment, thermal loads, and economics. Data sources in each of these areas were identified as well as solar radiation data stations and instruments.

  6. An ultrasensitive fouling monitoring system for cooling towers

    SciTech Connect

    Nohata, Y.; Taguchi, H.

    1995-03-01

    Fouling in industrial water has been a serious problem for many years. For example, the deterioration of the efficiency of heat exchangers and the occurrence of corrosion can cause cooling water leakage into the process streams. Biocides, dispersants, and filtration systems typically are used to prevent these problems. However, if these treatment programs are started too late, the early stages of fouling can occur. Here, a simple method for assessing fouling and chemical treatment efficiency is described. An ultrasensitive fouling sensor that uses piezoelectric quartz crystals was developed which detects fouling in the early stages.

  7. A Cooling System for the EAPU Shuttle Upgrade

    NASA Technical Reports Server (NTRS)

    Tongue, Stephen; Guyette, Greg; Irbeck, Bradley

    2001-01-01

    The Shuttle orbiter currently uses hydrazine-powered APU's for powering its hydraulic system pumps. To enhance vehicle safety and reliability, NASA is pursuing an APU upgrade where the hydrazine powered turbine is replaced by an electric motor pump and battery power supply. This EAPU (Electric APU) upgrade presents several thermal control challenges most notably the new requirement for moderate temperature control of high-power electron ics at 132 of (55.6 C). This paper describes how the existing Water Spray Boiler (WSB), which currently cools the hydraulic fluid and APU lubrication oil, is being modified to provide EAPU thermal management.

  8. Model Predictive Control for the Operation of Building Cooling Systems

    SciTech Connect

    Ma, Yudong; Borrelli, Francesco; Hencey, Brandon; Coffey, Brian; Bengea, Sorin; Haves, Philip

    2010-06-29

    A model-based predictive control (MPC) is designed for optimal thermal energy storage in building cooling systems. We focus on buildings equipped with a water tank used for actively storing cold water produced by a series of chillers. Typically the chillers are operated at night to recharge the storage tank in order to meet the building demands on the following day. In this paper, we build on our previous work, improve the building load model, and present experimental results. The experiments show that MPC can achieve reduction in the central plant electricity cost and improvement of its efficiency.

  9. Testing and design of solar cooling systems employing liquid dessicants

    SciTech Connect

    Lenz, T.; Loef, G.O.G.; Flaherty, M.; Misra, S.; Patnaik, S.

    1989-05-01

    An open cycle liquid desiccant cooling system with cooling capacity of 3 tons (10.5 kW) a subject of research at Colorado State University. The system comprises two main units: the dehumidifier and the regenerator. Lithium bromide is the desiccant solution that dehumidifies the air stream during a counter-current, liquid-gas contacting in the packed tower. The regenerator concentrates the lithium bromide solution during a similar gas-liquid contacting using solar heated air with the only difference being that the direction of heat and mass transfer are reversed in this unit. The earlier studies conducted on the dehumidifier revealed significant departures from an energy balance closure. An attempt has been made to provide a realistic energy balance closure to the dehumidifier side. This has resulted in substantial re-calibration of the major instruments involved. Performance data of the entire system with the regenerator and dehumidifier operated in coupled mode have been presented. An optimization scheme to predict operating conditions suited for best performance of the two units, for varying ambient temperature and humidity to the dehumidifier, has been devised. 15 refs., 20 figs., 8 tabs.

  10. Confined Phase Envelope of Gas-Condensate Systems in Shale Rocks

    NASA Astrophysics Data System (ADS)

    Nagy, Stanislaw; Siemek, Jakub

    2014-12-01

    Natural gas from shales (NGS) and from tight rocks are one of the most important fossil energy resource in this and next decade. Significant increase in gas consumption, in all world regions, will be marked in the energy sector. The exploration of unconventional natural gas & oil reservoirs has been discussed recently in many conferences. This paper describes the complex phenomena related to the impact of adsorption and capillary condensation of gas-condensate systems in nanopores. New two phase saturation model and new algorithm for search capillary condensation area is discussed. The algorithm is based on the Modified Tangent Plane Criterion for Capillary Condensation (MTPCCC) is presented. The examples of shift of phase envelopes are presented for selected composition of gas-condensate systems. Gaz ziemny z łupków (NGS) oraz z ze złóż niskoprzepuszczalnych (typu `tight') staje się jednym z najważniejszych zasobów paliw kopalnych, w tym i następnym dziesięcioleciu. Znaczący wzrost zużycia gazu we wszystkich regionach świata zaznacza się głównie w sektorze energetycznym. Rozpoznawanie niekonwencjonalnych złóż gazu ziemnego i ropy naftowej w ostatnim czasie jest omawiane w wielu konferencjach. Niniejszy artykuł opisuje złożone zjawiska związane z wpływem adsorpcji i kapilarnej kondensacji w nanoporach w złożach gazowo-kondensatowych. Pokazano nowy dwufazowy model równowagowy dwufazowy i nowy algorytm wyznaczania krzywej nasycenia w obszarze kondensacji kapilarnej. Algorytm bazuje na kryterium zmodyfikowanym płaszczyzny stycznej dla kapilarnej kondensacji (MTPCCC). Przykłady zmiany krzywych nasycenia są przedstawiane w wybranym składzie systemów gazowo- kondensatowych

  11. Controlling chaos in the Bose-Einstein condensate system of a double lattice

    SciTech Connect

    Wang Zhixia Ni Zhengguo; Cong Fuzhong; Liu Xueshen; Chen Lei

    2011-02-15

    We study the chaotic dynamics in the Bose-Einstein condensate (BEC) system of a double lattice. Chaotic space-time evolution is investigated for the particle number density in a BEC. By changing of the s-wave scattering length with a Feshbach resonance, the chaotic behavior can be well controlled to enter into periodicity. Numerical calculation shows that there is periodic orbit according to the s-wave scattering length only if the maximal Lyapunov exponent of the system is negative.

  12. Experimental and CFD Analysis of Advanced Convective Cooling Systems

    SciTech Connect

    Hassan, Yassin A; Ugaz, Victor M

    2012-06-27

    The objective of this project is to study the fundamental physical phenomena in the reactor cavity cooling system (RCCS) of very high-temperature reactors (VHTRs). One of the primary design objectives is to assure that RCCS acts as an ultimate heat sink capable of maintaining thermal integrity of the fuel, vessel, and equipment within the reactor cavity for the entire spectrum of postulated accident scenarios. Since construction of full-scale experimental test facilities to study these phenomena is impractical, it is logical to expect that computational fluid dynamics (CFD) simulations will play a key role in the RCCS design process. An important question then arises: To what extent are conventional CFD codes able to accurately capture the most important flow phenomena, and how can they be modified to improve their quantitative predictions? Researchers are working to tackle this problem in two ways. First, in the experimental phase, the research team plans to design and construct an innovative platform that will provide a standard test setting for validating CFD codes proposed for the RCCS design. This capability will significantly advance the state of knowledge in both liquid-cooled and gas-cooled (e.g., sodium fast reactor) reactor technology. This work will also extend flow measurements to micro-scale levels not obtainable in large-scale test facilities, thereby revealing previously undetectable phenomena that will complement the existing infrastructure. Second, in the computational phase of this work, numerical simulation of the flow and temperature profiles will be performed using advanced turbulence models to simulate the complex conditions of flows in critical zones of the cavity. These models will be validated and verified so that they can be implemented into commercially available CFD codes. Ultimately, the results of these validation studies can then be used to enable a more accurate design and safety evaluation of systems in actual nuclear power

  13. Excitonic condensation in spatially separated one-dimensional systems

    SciTech Connect

    Abergel, D. S. L.

    2015-05-25

    We show theoretically that excitons can form from spatially separated one-dimensional ground state populations of electrons and holes, and that the resulting excitons can form a quasicondensate. We describe a mean-field Bardeen-Cooper-Schrieffer theory in the low carrier density regime and then focus on the core-shell nanowire giving estimates of the size of the excitonic gap for InAs/GaSb wires and as a function of all the experimentally relevant parameters. We find that optimal conditions for pairing include small overlap of the electron and hole bands, large effective mass of the carriers, and low dielectric constant of the surrounding media. Therefore, one-dimensional systems provide an attractive platform for the experimental detection of excitonic quasicondensation in zero magnetic field.

  14. Biofouling studies with methylchloro/methylisothiazolone in model cooling systems

    SciTech Connect

    Williams, T.M.; Holz, J.W. Jr.

    1998-12-31

    Model systems were developed to evaluate microbial growth on surfaces and to determine the efficacy of biocides. Dynamic systems were used to simulate key operating parameters in industrial cooling towers. Biofouling was measured on wood, stainless steel, and heat transfer surfaces. Biocide testing in these model systems showed that methylchloro-methylisothiazolone was effective in controlling microbial growth in biofilms. The efficacy of the isothiazolone biocide was related to the treatment level and the nutrient content of the recirculating water. Biofilm control was monitored using viable counts of microorganisms as well as measuring specific biomass components (protein and carbohydrate) on surfaces. An on-line fouling monitor (heat exchanger) confirmed that low biofilm growth correlated with low heat transfer resistance.

  15. THERMAL DESIGN OF THE ITER VACUUM VESSEL COOLING SYSTEM

    SciTech Connect

    Carbajo, Juan J; Yoder Jr, Graydon L; Kim, Seokho H

    2010-01-01

    RELAP5-3D models of the ITER Vacuum Vessel (VV) Primary Heat Transfer System (PHTS) have been developed. The design of the cooling system is described in detail, and RELAP5 results are presented. Two parallel pump/heat exchanger trains comprise the design one train is for full-power operation and the other is for emergency operation or operation at decay heat levels. All the components are located inside the Tokamak building (a significant change from the original configurations). The results presented include operation at full power, decay heat operation, and baking operation. The RELAP5-3D results confirm that the design can operate satisfactorily during both normal pulsed power operation and decay heat operation. All the temperatures in the coolant and in the different system components are maintained within acceptable operating limits.

  16. Microbiological corrosion control in a cooling water system

    SciTech Connect

    Honneysett, D.G.; vanden Bergh, W.D.; O'Brien, P.F.

    1985-10-01

    The failure of a corrosion control program in a closed cooling water system coincided with the use of reclaimed sewage water and the contamination of the system with oil. Other problems were increased corrosion rates, downward pH excursions, increased fouling by corrosion by-products, and increased microbiological activity in the system. The major cause of corrosion was microbiological in origin. The unsuccessful use of a biocide led to the initiation of a full-scale microbiological investigation. The nature of the microflora was determined, biocide selection tests made, and an effective control treatment program initiated. Chromate corrosion treatment was replaced by a coordinated program using an organic filming corrosion inhibitor, a polyacrylate/phosphonate dispersant, and a combination of biocides.

  17. Reliability and Maintainability Data for Liquid Metal Cooling Systems

    SciTech Connect

    Cadwallader, Lee Charles

    2015-05-01

    One of the coolants of interest for future fusion breeding blankets is lead-lithium. As a liquid metal it offers the advantages of high temperature operation for good station efficiency, low pressure, and moderate flow rate. This coolant is also under examination for use in test blanket modules to be used in the ITER international project. To perform reliability, availability, maintainability and inspectability (RAMI) assessment as well as probabilistic safety assessment (PSA) of lead-lithium cooling systems, component failure rate data are needed to quantify the system models. RAMI assessment also requires repair time data and inspection time data. This paper presents a new survey of the data sets that are available at present to support RAMI and PSA quantification. Recommendations are given for the best data values to use when quantifying system models.

  18. Cooled electronic system with liquid-cooled cold plate and thermal spreader coupled to electronic component

    DOEpatents

    Chainer, Timothy J.; Graybill, David P.; Iyengar, Madhusudan K.; Kamath, Vinod; Kochuparambil, Bejoy J.; Schmidt, Roger R.; Steinke, Mark E.

    2016-04-05

    Apparatus and method are provided for facilitating cooling of an electronic component. The apparatus includes a liquid-cooled cold plate and a thermal spreader associated with the cold plate. The cold plate includes multiple coolant-carrying channel sections extending within the cold plate, and a thermal conduction surface with a larger surface area than a surface area of the component to be cooled. The thermal spreader includes one or more heat pipes including multiple heat pipe sections. One or more heat pipe sections are partially aligned to a first region of the cold plate, that is, where aligned to the surface to be cooled, and partially aligned to a second region of the cold plate, which is outside the first region. The one or more heat pipes facilitate distribution of heat from the electronic component to coolant-carrying channel sections of the cold plate located in the second region of the cold plate.

  19. Cooled electronic system with liquid-cooled cold plate and thermal spreader coupled to electronic component

    DOEpatents

    Chainer, Timothy J.; Graybill, David P.; Iyengar, Madhusudan K.; Kamath, Vinod; Kochuparambil, Bejoy J.; Schmidt, Roger R.; Steinke, Mark E.

    2016-08-09

    Apparatus and method are provided for facilitating cooling of an electronic component. The apparatus includes a liquid-cooled cold plate and a thermal spreader associated with the cold plate. The cold plate includes multiple coolant-carrying channel sections extending within the cold plate, and a thermal conduction surface with a larger surface area than a surface area of the component to be cooled. The thermal spreader includes one or more heat pipes including multiple heat pipe sections. One or more heat pipe sections are partially aligned to a first region of the cold plate, that is, where aligned to the surface to be cooled, and partially aligned to a second region of the cold plate, which is outside the first region. The one or more heat pipes facilitate distribution of heat from the electronic component to coolant-carrying channel sections of the cold plate located in the second region of the cold plate.

  20. Optimized readout system for cooled optically stimulated luminescence

    NASA Astrophysics Data System (ADS)

    Miller, S. D.; Eschbach, P. A.

    1990-09-01

    Cooled Optically Stimulated Luminescence (COSL) in CaF2:Mn is an ionizing radiation dosimetry method recently developed at the Pacific Northwest Laboratory (PNL). In this method CaF2:Mn crystals irradiated by gamma radiation at room temperature are cooled to liquid nitrogen temperature (77 K), stimulated by ultraviolet laser light at 326 nm, and allowed to warm to room temperature. Light emission proportional to the gamma exposure occurs as the TLD warms from liquid nitrogen temperature to room temperature. The new method is an example of a highly sensitive phototransfer technique which could form the basis for future radiation dosimetry applications. Measurements to date have shown high potential for measuring gamma exposures in the range of 10 microR. The high sensitivity of the COSL technique is due in part to the larger quantum efficiency of radiative recombination at low temperatures and to the complete absence of the incandescent background associated with conventional thermoluminescent readout methods. Along with the potential for a system which is more sensitive than thermoluminescent readers, multiple COSL readouts can be performed with minimal reduction in the COSL intensity. The multiple readout capability can serve as a possible permanent dosimetry record, thus allowing the reanalysis of a questionable reading. In an attempt to optimize the sensitivity of the COSL method, a new readout system is being developed.