Sample records for conformal radiotherapy planning

  1. Geometrical pre-planning for conformal radiotherapy.

    PubMed

    Tsougos, Ioannis; Schreibmann, Eduard; Lahanas, Michael; Theodorou, Kiki; Kappas, Constantin; Baltas, Dimos

    2007-01-01

    The optimum selection of beams and arcs in conformal techniques is of the outmost importance in modern radiotherapy. In this work we give a description of an analytic method to aid optimum selection, which is based on minimizing the intersection between beams and organs at risk (OAR) and on minimizing the intersection between the beam and the planning target volume (PTV). An arc-selection function that permits selection of irradiation arcs based on individual beam feasibility is introduce. The method simulates the treatment process by defining a computed beam feasibility, for every possible set of gantry-table angles, by taking into account accurately computer intersection volumes between the OAR and beams. The beams are shaped to conform the target using realistic parameters for the treatment process. The results are displayed on a virtual sphere centred at the isocenter with color-coded regions indicating beam feasibility. Arcs selections are performed by searching the map for successive gantry positions at a certain table angle, with feasibility values greater than a user-specified threshold. The accuracy of the method was confirmed by using geometrical regular shapes, as well as real clinical cases. PMID:17851850

  2. Dosimetric Comparison Between 3-Dimensional Conformal and Robotic SBRT Treatment Plans for Accelerated Partial Breast Radiotherapy.

    PubMed

    Goggin, L M; Descovich, M; McGuinness, C; Shiao, S; Pouliot, J; Park, C

    2016-06-01

    Accelerated partial breast irradiation is an attractive alternative to conventional whole breast radiotherapy for selected patients. Recently, CyberKnife has emerged as a possible alternative to conventional techniques for accelerated partial breast irradiation. In this retrospective study, we present a dosimetric comparison between 3-dimensional conformal radiotherapy plans and CyberKnife plans using circular (Iris) and multi-leaf collimators. Nine patients who had undergone breast-conserving surgery followed by whole breast radiation were included in this retrospective study. The CyberKnife planning target volume (PTV) was defined as the lumpectomy cavity + 10 mm + 2 mm with prescription dose of 30 Gy in 5 fractions. Two sets of 3-dimensional conformal radiotherapy plans were created, one used the same definitions as described for CyberKnife and the second used the RTOG-0413 definition of the PTV: lumpectomy cavity + 15 mm + 10 mm with prescription dose of 38.5 Gy in 10 fractions. Using both PTV definitions allowed us to compare the dose delivery capabilities of each technology and to evaluate the advantage of CyberKnife tracking. For the dosimetric comparison using the same PTV margins, CyberKnife and 3-dimensional plans resulted in similar tumor coverage and dose to critical structures, with the exception of the lung V5%, which was significantly smaller for 3-dimensional conformal radiotherapy, 6.2% when compared to 39.4% for CyberKnife-Iris and 17.9% for CyberKnife-multi-leaf collimator. When the inability of 3-dimensional conformal radiotherapy to track motion is considered, the result increased to 25.6%. Both CyberKnife-Iris and CyberKnife-multi-leaf collimator plans demonstrated significantly lower average ipsilateral breast V50% (25.5% and 24.2%, respectively) than 3-dimensional conformal radiotherapy (56.2%). The CyberKnife plans were more conformal but less homogeneous than the 3-dimensional conformal radiotherapy plans. Approximately 50% shorter

  3. Three-dimensional conformal versus intensity-modulated radiotherapy dose planning in stereotactic radiotherapy: Application of standard quality parameters for plan evaluation

    SciTech Connect

    Grzadziel, Aleksandra; Grosu, Anca-Ligia . E-mail: anca-ligia.grosu@lrz.tum.de; Kneschaurek, Peter

    2006-11-15

    Purpose: The implementation of intensity-modulated radiotherapy (IMRT) technique into clinical practice is becoming routine, but still lacks a generally accepted method for plan evaluation. We present a comparison of the dose distribution of conformal three-dimensional radiotherapy plans with IMRT plans for cranial lesions in stereotactic radiotherapy. The primary aim of this study was to judge the quality of the treatment plans. The next purpose was to assess the usefulness of several quality factors for plan evaluation. Methods and Materials: Five patients, who were treated in our department, were analyzed. Four had meningioma and one had pituitary adenoma. For each case, 10 different plans were created and analyzed: 2 conventional conformal three-dimensional plans and 8 IMRT plans, using the 'step and shoot' delivery method. The first conventional plan was an individually designed beam arrangement and was used for patient treatment. The second plan was a standard plan with the same beam arrangement for all patients. Beam arrangements from the conformal plans were the base for the inversely planned IMRT. To evaluate the plans, the following factors were investigated: minimal and maximal dose to the planning target volume, homogeneity index, coverage index, conformity index, and tumor control probabilities and normal tissue complication probabilities. These quantities were incorporated into scoring factors and assigned to each plan. Results: The greatest homogeneity was reached in the conformal plans and IMRT plans with high planning target volume priority in the optimization process. This consequently led to a better probability of tumor control. Better protection of organs at risk and thereby lower normal tissue complication probabilities were achieved in the IMRT plans with increased weighting of the organs at risk. Conclusion: These results show the efficiency, as well as some limitations, of the IMRT techniques. The use of different quality factors allowed us

  4. A maximum-entropy method for the planning of conformal radiotherapy.

    PubMed

    Wu, X; Zhu, Y

    2001-11-01

    The maximum entropy method (MEM) is a powerful inverse analysis technique that is used in many fields of science and engineering to perform tasks such as image reconstruction and processing of nuclear magnetic resonance signals. Unlike other methods, MEM naturally incorporates a priori knowledge of the problem into the optimized cost function. This feature is especially important in radiotherapy planning, because some knowledge is usually available about the stage of tumor development and about the prescription doses, including some dose constraints to the surrounding normal organs. Inverse planning is inherently consistent with the ability of MEM to estimate parameters inversely. In this investigation, an entropy function determines the homogeneity of dose distribution in the planning target volume; a least-squares function is added to the maximum entropy function as a constraint to measure the quality of reconstructed doses in organs at risk; and an iterative Newton-Ralphson algorithm searches for the optimization solution. Here we provide two examples that validate this application of MEM and the results were compared with manual plans. Although the examples involve conformal radiotherapy, we think MEM can be adopted to optimize intensity-modulated radiation therapy. PMID:11764028

  5. Treatment Planning Study to Determine Potential Benefit of Intensity-Modulated Radiotherapy Versus Conformal Radiotherapy for Unresectable Hepatic Malignancies

    SciTech Connect

    Eccles, Cynthia L.; Bissonnette, Jean-Pierre; Craig, Tim; Taremi, Mojgan; Wu Xia; Dawson, Laura A.

    2008-10-01

    Purpose: To compare intensity-modulated radiotherapy (IMRT) with conformal RT (CRT) for hypofractionated isotoxicity liver RT and explore dose escalation using IMRT for the same/improved nominal risk of liver toxicity in a treatment planning study. Methods and Materials: A total of 26 CRT plans were evaluated. Prescription doses (24-54 Gy within six fractions) were individualized on the basis of the effective liver volume irradiated maintaining {<=}5% risk of radiation-induced liver disease. The dose constraints included bowel (0.5 cm{sup 3}) and stomach (0.5 cm{sup 3}) to {<=}30 Gy, spinal cord to {<=}25 Gy, and planning target volume (PTV) to {<=}140% of the prescribed dose. Two groups were evaluated: (1) PTV overlapping or directly adjacent to serial functioning normal tissues (n = 14), and (2) the liver as the dose-limiting normal tissue (n = 12). IMRT plans using direct machine parameter optimization maintained the CRT plan beam arrangements, an estimated radiation-induced liver disease risk of 5%, and underwent dose escalation, if all normal tissue constraints were maintained. Results: IMRT improved PTV coverage in 19 of 26 plans (73%). Dose escalation was feasible in 9 cases by an average of 3.8 Gy (range, 0.6-13.2) in six fractions. Three of seven plans without improved PTV coverage had small gross tumor volumes ({<=}105 cm{sup 3}) already receiving 54 Gy, the maximal prescription dose allowed. In the remaining cases, the PTV range was 9.6-689 cm{sup 3}; two had overlapped organs at risk; and one had four targets. IMRT did not improve these plans owing to poor target coverage (n = 2) and nonliver (n = 2) dose limits. Conclusion: Direct machine parameter optimization IMRT improved PTV coverage while maintaining normal tissue tolerances in most CRT liver plans. Dose escalation was possible in a minority of patients.

  6. Adjuvant Radiotherapy for Gastric Cancer: A Dosimetric Comparison of 3-Dimensional Conformal Radiotherapy, Tomotherapy (registered) and Conventional Intensity Modulated Radiotherapy Treatment Plans

    SciTech Connect

    Dahele, Max; Skinner, Matthew; Schultz, Brenda; Cardoso, Marlene; Bell, Chris; Ung, Yee C.

    2010-07-01

    Some patients with gastric cancer benefit from post-operative chemo-radiotherapy, but adequately irradiating the planning target volume (PTV) whilst avoiding organs at risk (OAR) can be difficult. We evaluate 3-dimensional conformal radiotherapy (CRT), conventional intensity-modulated radiotherapy (IMRT) and helical tomotherapy (TT). TT, 2 and 5-field (F) CRT and IMRT treatment plans with the same PTV coverage were generated for 5 patients and compared. Median values are reported. The volume of left/right kidney receiving at least 20Gy (V20) was 57/51% and 51/60% for 2 and 5F-CRT, and 28/14% for TT and 27/19% for IMRT. The volume of liver receiving at least 30Gy (V30) was 45% and 62% for 2 and 5F-CRT, and 37% for TT and 35% for IMRT. With TT, 98% of the PTV received 95-105% of the prescribed dose, compared with 45%, 34% and 28% for 2F-CRT, 5F-CRT and IMRT respectively. Using conventional metrics, conventional IMRT can achieve comparable PTV coverage and OAR sparing to TT, but at the expense of PTV dose heterogeneity. Both irradiate large volumes of normal tissue to low doses. Additional studies are needed to demonstrate the clinical impact of these technologies.

  7. Conformal 3D planned radiotherapy for pelvic lymphoceles following surgery for urological cancer: A case study

    PubMed Central

    Janssen, Stefan; Käsmann, Lukas; Cegla, Robert; Rades, Dirk

    2016-01-01

    The aim of the present study was to evaluate the outcome and toxicity of 3D conformal radiotherapy (RT) for persistent lymphoceles following surgery for urological cancer. A total of 6 patients with bladder (n=1) and prostate cancer (n=5), with persistent lymphoceles following surgery for a primary tumor were treated with total doses of 10–12 Gy (1 Gy single dose) after computed tomography (CT) based 3D planning in order to suspend secretion. No acute or chronic toxicities were observed. In 5 patients, secretion of lymph fluid resolved after RT and in 1 patient RT had no effect. After a mean follow-up of 21 months (range, 5–47 months), no patient suffered from any symptoms concerning his former lymphoceles. This is the first analysis, to the best of our knowledge, to evaluate a homogenous patient collective of urological cancer patients with persistent lymphoceles after surgery for the initial tumor. RT to lymphoceles in urological cancer patient is effective, very well-tolerated and should be offered to patients with persistent secretion following drainage.

  8. [Planning and implementation of conformal radiotherapy for patients with gynecologic neoplasms with urinary tract obstruction].

    PubMed

    Kreinina, Yu M; Shevchenko, L N; Titova, V A; Teliyants, A F

    2015-01-01

    Urinary tract pathology is one of the reasons limiting possibility of all kind of radical treatment followed by proper rehabilitation in patients with cancer of the female genital organs. 469 patients suffering from cancer of the female genital organs with urological obstructive complications were successfully treated by means of conformal external beam radiotherapy and brachytherapy for the period 2003-2012 after correction of urological pathology. A use of interventional technologies for urinary tract drainage that minimize the frequency of repeated invasive procedures to reduce the risk of remote infectious and functional urinal complications after radiotherapy is the most priority for the implementation of irradiation of any required volume in patients with cancer of the female genital organs. PMID:26571829

  9. Comparison of intensity-modulated radiotherapy with three-dimensional conformal radiation therapy planning for glioblastoma multiforme

    SciTech Connect

    Chan, Maria F.; Schupak, Karen; Burman, Chandra; Chui, C.-S.; Ling, C. Clifton

    2003-12-31

    This study was designed to assess the feasibility and potential benefit of using intensity-modulated radiotherapy (IMRT) planning for patients newly diagnosed with glioblastoma multiforme (GBM). Five consecutive patients with confirmed histopathologically GBM were entered into the study. These patients were planned and treated with 3-dimensional conformal radiation therapy (3DCRT) using our standard plan of 3 noncoplanar wedged fields. They were then replanned with the IMRT method that included a simultaneous boost to the gross tumor volume (GTV). The dose distributions and dose-volume histograms (DHVs) for the planning treatment volume (PTV), GTV, and the relevant critical structures, as obtained with 3DCRT and IMRT, respectively, were compared. In both the 3DCRT and IMRT plans, 59.4 Gy was delivered to the GTV plus a margin of 2.5 cm, with doses to critical structures below the tolerance threshold. However, with the simultaneous boost in IMRT, a higher tumor dose of {approx}70 Gy could be delivered to the GTV, while still maintaining the uninvolved brain at dose levels of the 3DCRT technique. In addition, our experience indicated that IMRT planning is less labor intensive and time consuming than 3DCRT planning. Our study shows that IMRT planning is feasible and efficient for radiotherapy of GBM. In particular, IMRT can deliver a simultaneous boost to the GTV while better sparing the normal brain and other critical structures.

  10. Whole breast and excision cavity radiotherapy plan comparison: Conformal radiotherapy with sequential boost versus intensity-modulated radiation therapy with a simultaneously integrated boost

    SciTech Connect

    Small, Katherine; Kelly, Chris; Beldham-Collins, Rachael; Gebski, Val

    2013-03-15

    A comparative study was conducted comparing the difference between (1) conformal radiotherapy (CRT) to the whole breast with sequential boost excision cavity plans and (2) intensity-modulated radiation therapy (IMRT) to the whole breast with simultaneously integrated boost to the excision cavity. The computed tomography (CT) data sets of 25 breast cancer patients were used and the results analysed to determine if either planning method produced superior plans. CT data sets from 25 past breast cancer patients were planned using (1) CRT prescribed to 50 Gy in 25 fractions (Fx) to the whole-breast planning target volume (PTV) and 10 Gy in 5Fx to the excision cavity and (2) IMRT prescribed to 60 Gy in 25Fx, with 60 Gy delivered to the excision cavity PTV and 50 Gy delivered to the whole-breast PTV, treated simultaneously. In total, 50 plans were created, with each plan evaluated by PTV coverage using conformity indices, plan maximum dose, lung dose, and heart maximum dose for patients with left-side lesions. CRT plans delivered the lowest plan maximum doses in 56% of cases (average CRT = 6314.34 cGy, IMRT = 6371.52 cGy). They also delivered the lowest mean lung dose in 68% of cases (average CRT = 1206.64 cGy, IMRT = 1288.37 cGy) and V20 in 88% of cases (average CRT = 20.03%, IMRT = 21.73%) and V30 doses in 92% of cases (average CRT = 16.82%, IMRT = 17.97%). IMRT created more conformal plans, using both conformity index and conformation number, in every instance, and lower heart maximum doses in 78.6% of cases (average CRT = 5295.26 cGy, IMRT = 5209.87 cGy). IMRT plans produced superior dose conformity and shorter treatment duration, but a slightly higher planning maximum and increased lung doses. IMRT plans are also faster to treat on a daily basis, with shorter fractionation.

  11. SU-E-T-562: Motion Tracking Optimization for Conformal Arc Radiotherapy Plans: A QUASAR Phantom Based Study

    SciTech Connect

    Xu, Z; Wang, I; Yao, R; Podgorsak, M

    2015-06-15

    Purpose: This study is to use plan parameters optimization (Dose rate, collimator angle, couch angle, initial starting phase) to improve the performance of conformal arc radiotherapy plans with motion tracking by increasing the plan performance score (PPS). Methods: Two types of 3D conformal arc plans were created based on QUASAR respiratory motion phantom with spherical and cylindrical targets. Sinusoidal model was applied to the MLC leaves to generate motion tracking plans. A MATLAB program was developed to calculate PPS of each plan (ranges from 0–1) and optimize plan parameters. We first selected the dose rate for motion tracking plans and then used simulated annealing algorithm to search for the combination of the other parameters that resulted in the plan of the maximal PPS. The optimized motion tracking plan was delivered by Varian Truebeam Linac. In-room cameras and stopwatch were used for starting phase selection and synchronization between phantom motion and plan delivery. Gaf-EBT2 dosimetry films were used to measure the dose delivered to the target in QUASAR phantom. Dose profiles and Truebeam trajectory log files were used for plan delivery performance evaluation. Results: For spherical target, the maximal PPS (PPSsph) of the optimized plan was 0.79: (Dose rate: 500MU/min, Collimator: 90°, Couch: +10°, starting phase: 0.83π). For cylindrical target, the maximal PPScyl was 0.75 (Dose rate: 300MU/min, Collimator: 87°, starting phase: 0.97π) with couch at 0°. Differences of dose profiles between motion tracking plans (with the maximal and the minimal PPS) and 3D conformal plans were as follows: PPSsph=0.79: %ΔFWHM: 8.9%, %Dmax: 3.1%; PPSsph=0.52: %ΔFWHM: 10.4%, %Dmax: 6.1%. PPScyl=0.75: %ΔFWHM: 4.7%, %Dmax: 3.6%; PPScyl=0.42: %ΔFWHM: 12.5%, %Dmax: 9.6%. Conclusion: By achieving high plan performance score through parameters optimization, we can improve target dose conformity of motion tracking plan by decreasing total MLC leaf travel distance

  12. Comparison of inverse-planned three-dimensional conformal radiotherapy and intensity-modulated radiotherapy for non-small-cell lung cancer

    SciTech Connect

    Christian, Judith A. . E-mail: judith.christian@nuh.nhs.uk; Bedford, James L.; Webb, Steve; Brada, Michael

    2007-03-01

    Purpose: Lungs are the major dose-limiting organ during radiotherapy (RT) for non-small-cell lung cancer owing to the development of pneumonitis. This study compared intensity-modulated RT (IMRT) with three-dimensional conformal RT (3D-CRT) in reducing the dose to the lungs. Methods: Ten patients with localized non-small-cell lung cancer underwent computed tomography (CT). The planning target volume (PTV) was defined and the organs at risk were outlined. An inverse-planning program, AutoPlan, was used to design the beam angle-optimized six-field noncoplanar 3D-CRT plans. Each 3D-CRT plan was compared with a series of five IMRT plans per patient. The IMRT plans were created using a commercial algorithm and consisted of a series of three, five, seven, and nine equidistant coplanar field arrangements and one six-field noncoplanar plan. The planning objectives were to minimize the lung dose while maintaining the dose to the PTV. The percentage of lung volume receiving >20 Gy (V{sub 20}) and the percentage of the PTV covered by the 90% isodose (PTV{sub 90}) were the primary endpoints. The PTV{sub 90}/V{sub 20} ratio was used as the parameter accounting for both the reduction in lung volume treated and the PTV coverage. Results: All IMRT plans, except for the three-field coplanar plans, improved the PTV{sub 90}/V{sub 20} ratio significantly compared with the optimized 3D-CRT plan. Nine coplanar IMRT beams were significantly better than five or seven coplanar IMRT beams, with an improved PTV{sub 90}/V{sub 20} ratio. Conclusion: The results of our study have shown that IMRT can reduce the dose to the lungs compared with 3D-CRT by improving the conformity of the plan.

  13. Palliative radiotherapy for thoracic spine metastases: Dosimetric advantage of three-dimensional conformal plans

    PubMed Central

    YEO, SEUNG-GU

    2015-01-01

    The aim of the present study was to investigate the dosimetric advantages of three-dimensional conformal radiation therapy (3DCRT) for thoracic spine metastases and compare it with conventional two-dimensional (2D) plans. Radiation therapy (RT) planning data of 10 patients with mid-to-low thoracic spine metastases were analyzed. Computed tomography simulation was performed and the planning target volume (PTV), heart, esophagus, lung and spinal cord were contoured. The 3DCRT plan comprised one posteroanterior (PA) field and two posterior oblique fields. The 2D plans used a single PA field or opposed anteroposterior (AP)/PA fields. The prescription dose of radiation was 30 Gy in 10 fractions. All comparisons of the maximum or mean doses to the organs at risk or the PTV, between two of the three RT plans, demonstrated statistically significant differences (P<0.05), with the exception of the mean esophageal doses between the single PA vs. AP/PA (P=0.285) plans. The mean heart doses were 15.0±3.1 Gy in single PA, 17.3±4.3 Gy in AP/PA and 8.5±1.7 Gy using 3DCRT. The median reduction rates using 3DCRT were 38.9% compared with single PA (range, 29.4–58.5%) or 47.5% relative to AP/PA (range, 34.5–67.1%). The mean esophageal doses were 17.9±2.3 Gy in single PA, 18.2±2.2 Gy in AP/PA and 15.3±1.9 Gy in 3DCRT. The median reduction rate using 3DCRT was 12.8% compared with single PA or 15.6% relative to AP/PA. Compared with the single PA or AP/PA 2D plan, 3DCRT reduced the median dose by 13.7 or 1.9% of the maximum spinal cord dose, respectively, and 14.7 or 2.9% of the maximum PTV dose, respectively. The mean lung doses were 2.7±0.7 Gy in single PA, 2.6±0.7 Gy in AP/PA and 5.1±1.0 Gy in 3DCRT. In conclusion, 3DCRT for mid-to-low thoracic spine metastases demonstrated significant dosimetric advantages by reducing the unnecessary irradiation of critical organs, particularly the heart, and by achieving a homogeneous target dose. PMID:26171058

  14. Planning National Radiotherapy Services

    PubMed Central

    Rosenblatt, Eduardo

    2014-01-01

    Countries, states, and island nations often need forward planning of their radiotherapy services driven by different motives. Countries without radiotherapy services sponsor patients to receive radiotherapy abroad. They often engage professionals for a feasibility study in order to establish whether it would be more cost-beneficial to establish a radiotherapy facility. Countries where radiotherapy services have developed without any central planning, find themselves in situations where many of the available centers are private and thus inaccessible for a majority of patients with limited resources. Government may decide to plan ahead when a significant exodus of cancer patients travel to another country for treatment, thus exposing the failure of the country to provide this medical service for its citizens. In developed countries, the trigger has been the existence of highly visible waiting lists for radiotherapy revealing a shortage of radiotherapy equipment. This paper suggests that there should be a systematic and comprehensive process of long-term planning of radiotherapy services at the national level, taking into account the regulatory infrastructure for radiation protection, planning of centers, equipment, staff, education programs, quality assurance, and sustainability aspects. Realistic budgetary and cost considerations must also be part of the project proposal or business plan. PMID:25505730

  15. Intensity modulated radiotherapy and 3D conformal radiotherapy for whole breast irradiation: a comparative dosimetric study and introduction of a novel qualitative index for plan evaluation, the normal tissue index

    SciTech Connect

    Yim, Jackie; Suttie, Clare; Bromley, Regina; Morgia, Marita; Lamoury, Gillian

    2015-09-15

    We report on a retrospective dosimetric study, comparing 3D conformal radiotherapy (3DCRT) and hybrid intensity modulated radiotherapy (hIMRT). We evaluated plans based on their planning target volume coverage, dose homogeneity, dose to organs at risk (OARs) and exposure of normal tissue to radiation. The Homogeneity Index (HI) was used to assess the dose homogeneity in the target region, and we describe a new index, the normal tissue index (NTI), to assess the dose in the normal tissue inside the tangent treatment portal. Plans were generated for 25 early-stage breast cancer patients, using a hIMRT technique. These were compared with the 3DCRT plans of the treatment previously received by the patients. Plan quality was evaluated using the HI, NTI and dose to OARs. The hIMRT technique was significantly more homogenous than the 3DCRT technique, while maintaining target coverage. The hIMRT technique was also superior at minimising the amount of tissue receiving D{sub 105%} and above (P < 0.0001). The ipsilateral lung and contralateral breast maximum were significantly lower in the hIMRT plans (P < 0.05 and P < 0.005), but the 3DCRT technique achieved a lower mean heart dose in left-sided breast cancer patients (P < 0.05). Hybrid intensity modulated radiotherapy plans achieved improved dose homogeneity compared to the 3DCRT plans and superior outcome with regard to dose to normal tissues. We propose that the addition of both HI and NTI in evaluating the quality of intensity modulated radiotherapy (IMRT) breast plans provides clinically relevant comparators which more accurately reflect the new paradigm of treatment goals and outcomes in the era of breast IMRT.

  16. Intensity modulated radiotherapy and 3D conformal radiotherapy for whole breast irradiation: a comparative dosimetric study and introduction of a novel qualitative index for plan evaluation, the normal tissue index

    PubMed Central

    Yim, Jackie; Suttie, Clare; Bromley, Regina; Morgia, Marita; Lamoury, Gillian

    2015-01-01

    Introduction We report on a retrospective dosimetric study, comparing 3D conformal radiotherapy (3DCRT) and hybrid intensity modulated radiotherapy (hIMRT). We evaluated plans based on their planning target volume coverage, dose homogeneity, dose to organs at risk (OARs) and exposure of normal tissue to radiation. The Homogeneity Index (HI) was used to assess the dose homogeneity in the target region, and we describe a new index, the normal tissue index (NTI), to assess the dose in the normal tissue inside the tangent treatment portal. Methods Plans were generated for 25 early-stage breast cancer patients, using a hIMRT technique. These were compared with the 3DCRT plans of the treatment previously received by the patients. Plan quality was evaluated using the HI, NTI and dose to OARs. Results The hIMRT technique was significantly more homogenous than the 3DCRT technique, while maintaining target coverage. The hIMRT technique was also superior at minimising the amount of tissue receiving D105% and above (P < 0.0001). The ipsilateral lung and contralateral breast maximum were significantly lower in the hIMRT plans (P < 0.05 and P < 0.005), but the 3DCRT technique achieved a lower mean heart dose in left-sided breast cancer patients (P < 0.05). Conclusion Hybrid intensity modulated radiotherapy plans achieved improved dose homogeneity compared to the 3DCRT plans and superior outcome with regard to dose to normal tissues. We propose that the addition of both HI and NTI in evaluating the quality of intensity modulated radiotherapy (IMRT) breast plans provides clinically relevant comparators which more accurately reflect the new paradigm of treatment goals and outcomes in the era of breast IMRT. PMID:26451240

  17. Clinical Applications of 3-D Conformal Radiotherapy

    NASA Astrophysics Data System (ADS)

    Miralbell, Raymond

    Although a significant improvement in cancer cure (i.e. 20% increment) has been obtained in the last 2-3 decades, 30-40% of patients still fail locally after curative radiotherapy. In order to improve local tumor control rates with radiotherapy high doses to the tumor volume are frequently necessary. Three-dimensional conformal radiation therapy (3-D CRT) is used to denote a spectrum of radiation planning and delivery techniques that rely on three-dimensional imaging to define the target (tumor) and to distinguish it from normal tissues. Modern, high-precision radiotherapy (RT) techniques are needed in order to implement the goal of optimal tumor destruction delivering minimal dose to the non-target normal tissues. A better target definition is nowadays possible with contemporary imaging (computerized tomography, magnetic resonance imaging, and positron emission tomography) and image registration technology. A highly precise dose distributions can be obtained with optimal 3-D CRT treatment delivery techniques such as stereotactic RT, intensity modulated RT (IMRT), or protontherapy (the latter allowing for in-depth conformation). Patient daily set-up repositioning and internal organ immobilization systems are necessary before considering to undertake any of the above mentioned high-precision treatment approaches. Prostate cancer, brain tumors, and base of skull malignancies are among the sites most benefitting of dose escalation approaches. Nevertheless, a significant dose reduction to the normal tissues in the vicinity of the irradiated tumor also achievable with optimal 3-D CRT may also be a major issue in the treatment of pediatric tumors in order to preserve growth, normal development, and to reduce the risk of developing radiation induced diseases such as cancer or endocrinologic disorders.

  18. Intensity-Modulated Radiation Therapy Versus 3D Conformal Radiotherapy for Postoperative Gynecologic Cancer: Are They Covering the Same Planning Target Volume?

    PubMed Central

    Patil, Nikhilesh; D'souza, David; Millman, Barbara; Yaremko, Brian P; Leung, Eric; Whiston, Frances; Hajdok, George; Wong, Eugene

    2016-01-01

    Background and Purpose: This study compares dosimetric parameters of planning target volume (PTV) coverage and organs at risk (OAR) sparing when postoperative radiotherapy for gynecologic cancers is delivered using volumetric modulated arc therapy (VMAT) versus a four-field (4FLD) box technique. Material and Methods: From July to December 2012, women requiring postoperative radiation for gynecologic cancers were treated with a standardized VMAT protocol. Two sets of optimized 4FLD plans were retrospectively generated: one based on standard anatomical borders (4FLD) and one based on the clinical target volume (CTV) created for VMAT with a 2 cm expansion guiding field border placement (4FLD+2). Ninety-five percent isodose curves were generated to evaluate PTV coverage. Results: VMAT significantly improved dose conformity compared with 4FLD and 4FLD+2 plans (p < 0.001) and provided additional coverage of the PTV posteriorly and superiorly, corresponding to coverage of the presacral and proximal iliac vessels. There was a significant reduction in dose to all OARs with VMAT, including a 58% reduction in the volume of the small bowel receiving more than 45 Gy (p=0.005). Conclusions: Despite treating a larger volume, radiotherapy using a 4FLD technique is less homogenous and provides inferior coverage of the PTV compared with VMAT. With meticulous treatment planning and delivery, VMAT effectively encompasses the PTV and minimizes dose to OARs. PMID:26973802

  19. Can All Centers Plan Intensity-Modulated Radiotherapy (IMRT) Effectively? An External Audit of Dosimetric Comparisons Between Three-Dimensional Conformal Radiotherapy and IMRT for Adjuvant Chemoradiation for Gastric Cancer

    SciTech Connect

    Chung, Hans T. Lee, Brian; Park, Eileen; Lu, Jiade J.; Xia Ping

    2008-07-15

    Purpose: To compare dosimetric endpoints between three-dimensional conformal radiotherapy (3D-CRT) and intensity-modulated radiotherapy (IMRT) at our center with limited IMRT experience, and to perform an external audit of the IMRT plans. Methods and Materials: Ten patients, who received adjuvant chemoradiation for gastric cancer, formed the study cohort. For standardization, the planning target volume (PTV) and organs at risk were recontoured with the assistance of a study protocol radiologic atlas. The cohort was replanned with CMS Xio to generate coplanar 3D-CRT and IMRT plans. All 10 datasets, including volumes but without the plans (i.e., blinded), were transmitted to an experienced center where IMRT plans were designed using Nomos Corvus (IMRT-C) and ADAC Pinnacle (IMRT-P). All IMRT plans were normalized to D95% receiving 45 Gy. Results: Intensity-modulated radiotherapy yielded higher PTV V45 (volume that receives {>=}45 Gy) (p < 0.001) than 3D-CRT. No difference in V20 was seen in the right (p = 0.9) and left (p 0.3) kidneys, but the liver mean dose (p < 0.001) was superior with IMRT. For the external audit, IMRT-C (p = 0.002) and IMRT-P (p < 0.001) achieved significantly lower left kidney V20 than IMRT, and IMRT-P (p < 0.001) achieved lower right kidney V20 than IMRT. The IMRT-C (p = 0.003) but not IMRT-P (p = 0.6) had lower liver mean doses than IMRT. Conclusions: At our institution with early IMRT experience, IMRT improved PTV dose coverage and liver doses but not kidney doses. An external audit of IMRT plans showed that an experienced center can yield superior IMRT plans.

  20. Conformal Arc Radiotherapy for Prostate Cancer: Increased Biochemical Failure in Patients With Distended Rectum on the Planning Computed Tomogram Despite Image Guidance by Implanted Markers

    SciTech Connect

    Engels, Benedikt; Soete, Guy Verellen, D.; Storme, Guy

    2009-06-01

    Purpose: To evaluate the effect of rectal distention on the planning computed tomogram on freedom from biochemical failure (FFBF) of prostate cancer patients treated with image-guided conformal arc radiotherapy. Methods and Materials: The outcomes of 238 patients with T1-T3N0M0 tumors were analyzed, with a median follow-up of 53 months (range, 24-93 months). In 213 patients, daily co-registration of X-rays and digitally reconstructed radiographs was used for positioning, whereas in 25 patients positioning was done using direct prostate visualization with implanted markers. The rectal average cross-sectional area was determined on the planning computed tomogram. Results: The 5-year freedom from Grade 3 to 4 late gastrointestinal and urinary side effect, according to the Radiation Therapy Oncology Group criteria, was 100% and 99.4% respectively. The 5-year FFBF was 88.4%. On multivariate analysis the following variables were significantly related to worse FFBF: risk group according to the National Comprehensive Cancer Network (high- to very high risk vs. intermediate- to low-risk), dose (70 vs. 78 Gy), average cross-sectional area ({>=}16 vs. <16 cm{sup 2}) and, unexpectedly, the use of implanted markers as opposed to bony structures for patient positioning. In retrospect, the margins around the clinical target volume appeared to be inadequate in the cases in which markers were used. Conclusion: Overall, the outcome of patients treated with image-guided conformal arc radiotherapy is excellent. We were able to confirm the negative prognostic impact of a distended rectum on the planning computed tomogram described by others. The study illustrates the potential danger of image guidance techniques as to margin reduction around the clinical target volume.

  1. Conformal Radiotherapy Facilitates the Delivery of Concurrent Chemotherapy and Radiotherapy: A Case of Primitive Neuroectodermal Tumour of the Chest Wall

    PubMed Central

    Twyman, N.; Earl, H. M.; Burnet, N. G.

    2000-01-01

    We illustrate the principle of conformal radiotherapy by discussing the case of a patient with a primitive neuroectodermal tumour of the chest wall. Recent advances in radiotherapy planning enable precise localization of the planning target volume (PTV) and normal organs at risk of irradiation. Customized blocks are subsequently designed to produce a treatment field that ‘conforms’ to the PTV. The use of conformal radiotherapy (CRT) in this case facilitated the delivery of concurrent chemotherapy and radiotherapy by significantly reducing the volume of red marrow irradiated.The lack of acute and late toxicities was attributed to optimal exclusion of normal tissues from the treatment field, made possible by CRT. PMID:18521292

  2. Radiotherapy planning using MRI

    NASA Astrophysics Data System (ADS)

    Schmidt, Maria A.; Payne, Geoffrey S.

    2015-11-01

    The use of magnetic resonance imaging (MRI) in radiotherapy (RT) planning is rapidly expanding. We review the wide range of image contrast mechanisms available to MRI and the way they are exploited for RT planning. However a number of challenges are also considered: the requirements that MR images are acquired in the RT treatment position, that they are geometrically accurate, that effects of patient motion during the scan are minimized, that tissue markers are clearly demonstrated, that an estimate of electron density can be obtained. These issues are discussed in detail, prior to the consideration of a number of specific clinical applications. This is followed by a brief discussion on the development of real-time MRI-guided RT.

  3. Dosimetric comparison of three-dimensional conformal radiotherapy, intensity modulated radiotherapy, and helical tomotherapy for lung stereotactic body radiotherapy.

    PubMed

    Kinhikar, Rajesh Ashok; Ghadi, Yogesh G; Sahoo, Priyadarshini; Laskar, Sarbani Ghosh; Deshpande, Deepak D; Shrivastava, Shyam K; Agarwal, Jaiprakash

    2015-01-01

    To compare the treatment plans generated with three-dimensional conformal radiation therapy (3DCRT), intensity modulated radiotherapy (IMRT), and helical tomotherapy (HT) for stereotactic body radiotherapy of lung, twenty patients with medically inoperable (early nonsmall cell lung cancer) were retrospectively reviewed for dosimetric evaluation of treatment delivery techniques (3DCRT, IMRT, and HT). A dose of 6 Gy per fraction in 8 fractions was prescribed to deliver 95% of the prescription dose to 95% volume of planning target volume (PTV). Plan quality was assessed using conformity index (CI) and homogeneity index (HI). Doses to critical organs were assessed. Mean CI with 3DCRT, IMRT, and HT was 1.19 (standard deviation [SD] 0.13), 1.18 (SD 0.11), and 1.08 (SD 0.04), respectively. Mean HI with 3DCRT, IMRT, and HT was 1.14 (SD 0.05), 1.08 (SD 0.02), and 1.07 (SD 0.04), respectively. Mean R50% values for 3DCRT, IMRT, and HT was 8.5 (SD 0.35), 7.04 (SD 0.45), and 5.43 (SD 0.29), respectively. D2cm was found superior with IMRT and HT. Significant sparing of critical organs can be achieved with highly conformal techniques (IMRT and HT) without compromising the PTV conformity and homogeneity. PMID:26865754

  4. Proton Radiotherapy for Liver Tumors: Dosimetric Advantages Over Photon Plans

    SciTech Connect

    Wang Xiaochun Krishnan, Sunil; Zhang Xiaodong; Dong Lei; Briere, Tina; Crane, Christopher H.; Martel, Mary; Gillin, Michael; Mohan, Radhe; Beddar, Sam

    2008-01-01

    The purpose of the study is to dosimetrically investigate the advantages of proton radiotherapy over photon radiotherapy for liver tumors. The proton plan and the photon plan were designed using commercial treatment planning systems. The treatment target dose conformity and heterogeneity and dose-volume analyses of normal structures were compared between proton and photon radiotherapy for 9 patients with liver tumors. Proton radiotherapy delivered a more conformal target dose with slightly less homogeneity when compared with photon radiotherapy. Protons significantly reduced the fractional volume of liver receiving dose greater or equal to 30 Gy (V{sub 30}) and the mean liver dose. The stomach and duodenal V{sub 45} were significantly lower with the use of proton radiotherapy. The V{sub 40} and V{sub 50} of the heart and the maximum spinal cord dose were also significantly lower with the use of proton radiotherapy. Protons were better able to spare one kidney completely and deliver less dose to one (generally the left) kidney than photons. The mean dose to the total body and most critical structures was significantly decreased using protons when compared to corresponding photon plans. In conclusion, our study suggests the dosimetric benefits of proton radiotherapy over photon radiotherapy. These dosimetric advantages of proton plans may permit further dose escalation with lower risk of complications.

  5. Factors influencing conformity index in radiotherapy for non-small cell lung cancer.

    PubMed

    Brennan, Sinead M; Thirion, Pierre; Buckney, Steve; Shea, Carmel O; Armstrong, John

    2010-01-01

    The radiotherapy conformity index (CI) is a useful tool to quantitatively assess the quality of radiotherapy treatment plans, and represents the relationship between isodose distributions and target volume. A conformity index of unity implies high planning target volume (PTV) coverage and minimal unnecessary irradiation of surrounding tissues. We performed this analysis to describe the CI for lung cancer 3-dimensional conformal radiotherapy (3DCRT) and to identify clinical and technical determinants of CI, as it is not known which factors are associated with good quality 3D conformal radiotherapy treatment planning. Radiotherapy treatment plans from a database of 52 patients with inoperable Stage 1 to 3b lung cancer, on a hypofractionated 3DCRT trial were evaluated. A CI was calculated for all plans using the definition of the ICRU 62:CI = (TV/PTV), which is the quotient of the treated volume (TV) and the PTV. Data on patient, tumor, and planning variables, which could influence CI, were recorded and analyzed. Mean CI was 2.01 (range = 1.06-3.8). On univariate analysis, PTV (p = 0.023), number of beams (p = 0.036), medial vs. lateral tumor location (p = 0.016), and increasing tumor stage (p = 0.041) were associated with improved conformity. On multiple regression analysis, factors found to be associated with CI included central vs. peripheral tumor location (p = 0.041) and PTV size (p = 0.058). The term 3DCRT is used routinely in the literature, without any indication of the degree of conformality. We recommend routine reporting of conformity indices. Conformity indices may be affected by both planning variables and tumor factors. PMID:19931013

  6. Factors Influencing Conformity Index in Radiotherapy for Non-Small Cell Lung Cancer

    SciTech Connect

    Brennan, Sinead M. Thirion, Pierre; Buckney, Steve; Shea, Carmel O.; Armstrong, John

    2010-04-01

    The radiotherapy conformity index (CI) is a useful tool to quantitatively assess the quality of radiotherapy treatment plans, and represents the relationship between isodose distributions and target volume. A conformity index of unity implies high planning target volume (PTV) coverage and minimal unnecessary irradiation of surrounding tissues. We performed this analysis to describe the CI for lung cancer 3-dimensional conformal radiotherapy (3DCRT) and to identify clinical and technical determinants of CI, as it is not known which factors are associated with good quality 3D conformal radiotherapy treatment planning. Radiotherapy treatment plans from a database of 52 patients with inoperable Stage 1 to 3b lung cancer, on a hypofractionated 3DCRT trial were evaluated. A CI was calculated for all plans using the definition of the ICRU 62:CI = (TV/PTV), which is the quotient of the treated volume (TV) and the PTV. Data on patient, tumor, and planning variables, which could influence CI, were recorded and analyzed. Mean CI was 2.01 (range = 1.06-3.8). On univariate analysis, PTV (p = 0.023), number of beams (p = 0.036), medial vs. lateral tumor location (p = 0.016), and increasing tumor stage (p = 0.041) were associated with improved conformity. On multiple regression analysis, factors found to be associated with CI included central vs. peripheral tumor location (p = 0.041) and PTV size (p = 0.058). The term 3DCRT is used routinely in the literature, without any indication of the degree of conformality. We recommend routine reporting of conformity indices. Conformity indices may be affected by both planning variables and tumor factors.

  7. Comparison of forward planning with automated inverse planning for three-dimensional conformal radiotherapy of non-small cell lung cancer without IMRT.

    PubMed

    Mendes, Ruheena; Lavrenkov, Konstantin; Bedford, James L; Henrys, Anthony; Ashley, Sue; Brada, Michael

    2006-03-01

    The forward and inverse treatment plans of 10 patients with lung cancer were compared in terms of PTV coverage, sparing of normal lung and time required to generate a plan. The inverse planning produced as good treatment plans as an experienced dosimetrist with considerable reduction in staff time. When translated to other complex sites, inverse non-IMRT planning may have considerable impact on manpower requirements. PMID:16564591

  8. Radiotherapy Treatment Planning for Testicular Seminoma

    SciTech Connect

    Wilder, Richard B.; Buyyounouski, Mark K.; Efstathiou, Jason A.; Beard, Clair J.

    2012-07-15

    Virtually all patients with Stage I testicular seminoma are cured regardless of postorchiectomy management. For patients treated with adjuvant radiotherapy, late toxicity is a major concern. However, toxicity may be limited by radiotherapy techniques that minimize radiation exposure of healthy normal tissues. This article is an evidence-based review that provides radiotherapy treatment planning recommendations for testicular seminoma. The minority of Stage I patients who choose adjuvant treatment over surveillance may be considered for (1) para-aortic irradiation to 20 Gy in 10 fractions, or (2) carboplatin chemotherapy consisting of area under the curve, AUC = 7 Multiplication-Sign 1-2 cycles. Two-dimensional radiotherapy based on bony anatomy is a simple and effective treatment for Stage IIA or IIB testicular seminoma. Centers with expertise in vascular and nodal anatomy may consider use of anteroposterior-posteroanterior fields based on three-dimensional conformal radiotherapy instead. For modified dog-leg fields delivering 20 Gy in 10 fractions, clinical studies support placement of the inferior border at the top of the acetabulum. Clinical and nodal mapping studies support placement of the superior border of all radiotherapy fields at the top of the T12 vertebral body. For Stage IIA and IIB patients, an anteroposterior-posteroanterior boost is then delivered to the adenopathy with a 2-cm margin to the block edge. The boost dose consists of 10 Gy in 5 fractions for Stage IIA and 16 Gy in 8 fractions for Stage IIB. Alternatively, bleomycin, etoposide, and cisplatin chemotherapy for 3 cycles or etoposide and cisplatin chemotherapy for 4 cycles may be delivered to Stage IIA or IIB patients (e.g., if they have a horseshoe kidney, inflammatory bowel disease, or a history of radiotherapy).

  9. Conformal Radiotherapy in the Treatment of Advanced Juvenile Nasopharyngeal Angiofibroma With Intracranial Extension: An Institutional Experience

    SciTech Connect

    Chakraborty, Santam; Ghoshal, Sushmita; Patil, Vijay Maruti; Oinam, Arun Singh; Sharma, Suresh C.

    2011-08-01

    Purpose: To describe the results of conformal radiotherapy in advanced juvenile nasopharyngeal angiofibroma in a tertiary care institution. Methods and Materials: Retrospective chart review was conducted for 8 patients treated with conformal radiotherapy between 2006 and 2009. The median follow-up was 17 months. All patients had Stage IIIB disease with intracranial extension. Radiotherapy was considered as treatment because patients were deemed inoperable owing to extensive intracranial/intraorbital extension or proximity to optic nerve. All but 1 patient were treated with intensity-modulated radiotherapy using seven coplanar fields. Median (range) dose prescribed was 39.6 (30-46) Gy. Actuarial analysis of local control and descriptive analysis of toxicity profile was conducted. Results: Despite the large and complex target volume (median planning target volume, 292 cm{sup 3}), intensity-modulated radiotherapy achieved conformal dose distributions (median van't Reit index, 0.66). Significant sparing of the surrounding organs at risk was obtained. No significant Grade 3/4 toxicities were experienced during or after treatment. Actual local control at 2 years was 87.5%. One patient died 1 month after radiotherapy secondary to massive epistaxis. The remaining 7 patients had progressive resolution of disease and were symptom-free at last follow-up. Persistent rhinitis was the only significant toxicity, seen in 1 patient. Conclusions: Conformal radiotherapy results in good local control with minimal acute and late side effects in juvenile nasopharyngeal angiofibromas, even in the presence of advanced disease.

  10. Stereotactic Radiotherapy of Intracranial Tumors: A Comparison of Intensity-Modulated Radiotherapy and Dynamic Conformal Arc

    SciTech Connect

    Wiggenraad, Ruud G.J. Petoukhova, Anna L.; Versluis, Lia; Santvoort, Jan P.C. van

    2009-07-15

    Purpose: Intensity-modulated radiotherapy (IMRT) and dynamic conformal arc (DCA) are two state-of-the-art techniques for linac-based stereotactic radiotherapy (SRT) using the micromultileaf collimator. The purpose of this planning study is to examine the relative merits of these techniques in the treatment of intracranial tumors. Materials and Methods: SRT treatment plans were made for 25 patients with a glioma or meningioma. For all patients, we made an IMRT and a DCA plan. Plans were evaluated using: target coverage, conformity index (CI), homogeneity index (HI), doses in critical structures, number of monitor units needed, and equivalent uniform dose (EUD) in planning target volume (PTV) and critical structures. Results: In the overall comparison of both techniques, we found adequate target coverage in all cases; a better mean CI with IMRT in concave tumors (p = 0.027); a better mean HI with DCA in meningiomas, complex tumors, and small (< 92 mL) tumors (p = 0.000, p = 0.005, and p = 0.005, respectively); and a higher EUD in the PTV with DCA in convex tumors (gliomas) and large tumors (p = 0.000 and p = 0.003, respectively). In all patients, significantly more monitor units were needed with IMRT. The results of the overall comparison did not enable us to predict the preference for one of the techniques in individual patients. The DCA plan was acceptable in 23 patients and the IMRT plan in 19 patients. DCA was preferred in 18 of 25 patients. Conclusions: DCA is our preferred SRT technique for most intracranial tumors. Tumor type, size, or shape do not predict a preference for DCA or IMRT.

  11. Contribution of FDOPA PET to radiotherapy planning for advanced glioma

    NASA Astrophysics Data System (ADS)

    Dowson, Nicholas; Fay, Michael; Thomas, Paul; Jeffree, Rosalind; McDowall, Robert; Winter, Craig; Coulthard, Alan; Smith, Jye; Gal, Yaniv; Bourgeat, Pierrick; Salvado, Olivier; Crozier, Stuart; Rose, Stephen

    2014-03-01

    Despite radical treatment with surgery, radiotherapy and chemotherapy, advanced gliomas recur within months. Geographic misses in radiotherapy planning may play a role in this seemingly ineluctable recurrence. Planning is typically performed on post-contrast MRIs, which are known to underreport tumour volume relative to FDOPA PET scans. FDOPA PET fused with contrast enhanced MRI has demonstrated greater sensitivity and specificity than MRI alone. One sign of potential misses would be differences between gross target volumes (GTVs) defined using MRI alone and when fused with PET. This work examined whether such a discrepancy may occur. Materials and Methods: For six patients, a 75 minute PET scan using 3,4-dihydroxy-6-18F-fluoro-L-phynel-alanine (18F-FDOPA) was taken within 2 days of gadolinium enhanced MRI scans. In addition to standard radiotherapy planning by an experienced radiotherapy oncologist, a second gross target volume (GTV) was defined by an experienced nuclear medicine specialist for fused PET and MRI, while blinded to the radiotherapy plans. The volumes from standard radiotherapy planning were compared to the PET defined GTV. Results: The comparison indicated radiotherapy planning would change in several cases if FDOPA PET data was available. PET-defined contours were external to 95% prescribed dose for several patients. However, due to the radiotherapy margins, the discrepancies were relatively small in size and all received a dose of 50 Gray or more. Conclusions: Given the limited size of the discrepancies it is uncertain that geographic misses played a major role in patient outcome. Even so, the existence of discrepancies indicates that FDOPA PET could assist in better defining margins when planning radiotherapy for advanced glioma, which could be important for highly conformal radiotherapy plans.

  12. The advantages of three-dimensional conformal radiotherapy for treatment of childhood cancer.

    PubMed

    Smitt, M C; McPeak, E M; Donaldson, S S

    1998-11-01

    Three-dimensional treatment planning with delivery of conformal radiotherapy has been demonstrated to improve tumor targeting and to reduce normal tissue volume exposed in several studies of malignancies in adults. Furthermore, institutional clinical protocols have accomplished escalation of radiation dose with enhanced treatment efficacy and stable to decreased late effects in patients with prostate carcinoma. In the treatment of malignancies in children, there are several aspects of therapy which may be particularly amenable to improvement with three-dimensional treatment planning. First, the occurrence of large, irregular tumor volumes close to critical normal structures is common in solid tumors in children. The acquisition of detailed computerized tomography (CT) images at the time of simulation, along with the use of three-dimensional reconstruction and beam's-eye-view capabilities, should greatly improve tumor targeting and allow more selective blocking of normal structures. In addition, the enhanced sensitivity of developing organs and tissues to radiation in combination with high expectations for overall survival with current treatment programs has resulted in greater awareness of the late effects of treatment. Today, the goal of pediatric radiotherapy is to provide high rates of local tumor control without significant late effects, such as impairment of growth and development and injury to organ function. The use of conformal radiotherapy is likely to be an important advance in realizing this goal. The ability to use novel beam arrangements and to evaluate radiotherapy treatment plans with quantitative tools, such as dose-volume histogram analysis or probabilities of normal tissue complications, should enable the use of treatment programs with a lessened risk of late effects. However, the rarity of pediatric tumors is unlikely to permit a controlled trial of conformal compared to conventional therapy. In this article, we use three case illustrations to

  13. The Three Dimensional Conformal Radiotherapy for Hyperkeratotic Plantar Mycosis Fungoides

    PubMed Central

    Lee, Sun Young; Kwon, Hyoung Cheol; Cho, Yong-Sun; Nam, Kyung-Hwa; Ihm, Chull-Wan

    2011-01-01

    The localized early-stage of Mycosis fungoides (MF) (stage IA-IIA) is usually treated with topical agents, such as nitrogen mustard, steroids, and phototherapy (UVB/PUVA) as first line therapy; response to these initial treatments is usually good. However, hyperkeratotic plantar lesions are clinically rare and have decreased responsiveness to topical agents. For such cases, physicians may consider local radiotherapy. Here, a case of an 18-year-old Korean woman who was treated with three-dimensional conformal radiotherapy (3D-CRT) for hyperkeratotic plantar lesions that were refractory to UVA-1, methotrexate, and topical steroids is reported. Complete remission was attained after radiotherapy. During the one-year follow-up period, there has been no evidence of disease recurrence and no chronic complications have been observed. PMID:22028574

  14. Quality assurance devices for dynamic conformal radiotherapy.

    PubMed

    Wong, Victy Y M

    2004-01-01

    Two quality control devices, light-field device and radiation-field device, have been specially designed to facilitate the clinical implementation of conformal dynamic arc treatment (CDAT) and intensity modulated radiation therapy (IMRT). With the devices, the light field as well as the radiation field, projected from the individual beam at any treatment position (i.e. arbitrary gantry angle) can be evaluated. For application, the device was attached at the front end of the couch and was placed at the isocentre of the linear accelerator treatment system (LINAC). The devices are designed to be rotated parallel to the gantry head so that the light field and the radiation field projected from a direct beam can be assessed. The aim of the study is, with the aid of the devices, to evaluate the geometric precision of the beam placement and the dosimetric accuracy performed in CDAT and IMRT. The devices are placed separately from the LINAC during application and provide an independent check on the quality performance of the LINAC in three dimensions. The condition of gantry sag and any mechanical displacement resulting in field shift can be observed and traced during gantry rotation. Mistakes that occurred during the isocentre calibration can lead to significant displacement in the field projection, which would not be revealed with the conventional quality control setting (i.e. gantry 0(o)), was demonstrated with the aid of the devices here. The influence of gravitational acceleration in MLC leaf positioning error, which would consequently lead to inaccurate dose delivery, was investigated. The results of our study show that the existence of gravitational influence is statistically significant, although the magnitude of the dose inaccuracy has been found to be small. PMID:15753929

  15. Intensity-Modulated Radiotherapy Might Increase Pneumonitis Risk Relative to Three-Dimensional Conformal Radiotherapy in Patients Receiving Combined Chemotherapy and Radiotherapy: A Modeling Study of Dose Dumping

    SciTech Connect

    Vogelius, Ivan S.; Westerly, David C.; Cannon, George M.; Mackie, Thomas R.; Mehta, Minesh P.; Sugie, Chikao; Bentzen, Soren M.

    2011-07-01

    Purpose: To model the possible interaction between cytotoxic chemotherapy and the radiation dose distribution with respect to the risk of radiation pneumonitis. Methods and Materials: A total of 18 non-small-cell lung cancer patients previously treated with helical tomotherapy at the University of Wisconsin were selected for the present modeling study. Three treatment plans were considered: the delivered tomotherapy plans; a three-dimensional conformal radiotherapy (3D-CRT) plan; and a fixed-field intensity-modulated radiotherapy (IMRT) plan. The IMRT and 3D-CRT plans were generated specifically for the present study. The plans were optimized without adjusting for the chemotherapy effect. The effect of chemotherapy was modeled as an independent cell killing process by considering a uniform chemotherapy equivalent radiation dose added to all voxels of the organ at risk. The risk of radiation pneumonitis was estimated for all plans using the Lyman and the critical volume models. Results: For radiotherapy alone, the critical volume model predicts that the two IMRT plans are associated with a lower risk of radiation pneumonitis than the 3D-CRT plan. However, when the chemotherapy equivalent radiation dose exceeds a certain threshold, the radiation pneumonitis risk after IMRT is greater than after 3D-CRT. This threshold dose is in the range estimated from clinical chemoradiotherapy data sets. Conclusions: Cytotoxic chemotherapy might affect the relative merit of competing radiotherapy plans. More work is needed to improve our understanding of the interaction between chemotherapy and the radiation dose distribution in clinical settings.

  16. Adjuvant Radiotherapy with Three-Dimensional Conformal Radiotherapy of Lacrimal Gland Adenoid Cystic Carcinoma

    PubMed Central

    Roshan, Vikas; Mallick, Supriya; Chander, Subhash; Sen, Seema; Chawla, Bhavna

    2015-01-01

    Background & Aim Adenoid cystic carcinoma (ACC) of lacrimal gland is a rare tumour with aggressive behaviour. There is sparse data to address optimum therapy for such tumours. So, the present study was aimed at evaluating the role of adjuvant three dimensional conformal radiotherapy (3D-CRT) in cases of incomplete (R1) resection along with review of literature pertaining to management of lacrimal adenoid cystic carcinoma Materials and Methods We retrospectively reviewed the demographic and treatment data of 10 biopsy proven ACC of lacrimal gland patients, treated from December 2006 to June 2013. They were treated with radiotherapy following surgical resection. Eight patients underwent gross total excision of the tumour mass (enbloc excision) followed by conformal radiotherapy to a dose of 60 Gray/30fractions/ 6 weeks. Two patients with advanced disease were treated with palliative radiotherapy after biopsy. Results The median age was 32 years. There were equal numbers of male and female patients. The median duration of symptoms was 7 months. At a median follow up of 21 months, eight patients had no evidence of disease and had complete tumour response, two patients worsened, and one of the two had systemic failure with bone metastasis. Conclusion Despite a small sample size and short follow, enbloc surgical excision with adjuvant radiotherapy is well tolerated and shows good control in ACC of lacrimal gland. PMID:26557600

  17. Intensity-modulated radiotherapy, not 3D conformal, is the preferred technique for treating locally advanced lung cancer

    PubMed Central

    Chang, Joe Y.

    2015-01-01

    When used to treat lung cancer, intensity-modulated radiotherapy (IMRT) can deliver higher dose to the targets and spare more critical organs in lung cancer than can 3D conformal radiotherapy (3DCRT). However, tumor-motion management and optimized radiotherapy planning based on four-dimensional computed tomography (4D CT) scanning are crucial to maximize the benefit of IMRT and to eliminate or minimize potential uncertainties. This article summarizes these strategies and reviews published findings supporting the safety and efficacy of IMRT for lung cancer. PMID:25771415

  18. 3D-Conformal Versus Intensity-Modulated Postoperative Radiotherapy of Vaginal Vault: A Dosimetric Comparison

    SciTech Connect

    Cilla, Savino; Macchia, Gabriella Digesu, Cinzia; Deodato, Francesco; Romanella, Michele; Ferrandina, Gabriella; Padula, Gilbert; Picardi, Vincenzo; Scambia, Giovanni; Morganti, Alessio Giuseppe

    2010-07-01

    We evaluated a step-and-shoot IMRT plan in the postoperative irradiation of the vaginal vault compared with equispaced beam arrangements (3-5) 3D-radiotherapy (RT) optimized plans. Twelve patients were included in this analysis. Four plans for each patient were compared in terms of dose-volume histograms, homogeneity index (HI), and conformity index (CI): (1) 3 equispaced beam arrangement 3D-RT; (2) 4 equispaced beam arrangement 3D-RT; (3) 5 equispaced beam arrangement 3D-RT; (4) step-and-shoot IMRT technique. CI showed a good discrimination between the four plans. The mean scores of CI were 0.58 (range: 0.38-0.67) for the 3F-CRT plan, 0.58 (range: 0.41-0.66) for 4F-CRT, 0.62 (range: 0.43-0.68) for 5F-CRT and 0.69 (range: 0.58-0.78) for the IMRT plan. A significant improvement of the conformity was reached by the IMRT plan (p < 0.001 for all comparisons). As expected, the increment of 3D-CRT fields was associated with an improvement of target dose conformity and homogeneity; on the contrary, in the IMRT plans, a better conformity was associated to a worse target dose homogeneity. A significant reduction in terms of D{sub mean}, V90%, V95%, V100% was recorded for rectal and bladder irradiation with the IMRT plan. Surprisingly, IMRT supplied a significant dose reduction also for rectum and bladder V30% and V50%. A significant dosimetric advantage of IMRT over 3D-RT in the adjuvant treatment of vaginal vault alone in terms of treatment conformity and rectum and bladder sparing is shown.

  19. Retrospective evaluation of dosimetric quality for prostate carcinomas treated with 3D conformal, intensity modulated and volumetric modulated arc radiotherapy

    PubMed Central

    Crowe, Scott B; Kairn, Tanya; Middlebrook, Nigel; Hill, Brendan; Christie, David R H; Knight, Richard T; Kenny, John; Langton, Christian M; Trapp, Jamie V

    2013-01-01

    Introduction This study examines and compares the dosimetric quality of radiotherapy treatment plans for prostate carcinoma across a cohort of 163 patients treated across five centres: 83 treated with three-dimensional conformal radiotherapy (3DCRT), 33 treated with intensity modulated radiotherapy (IMRT) and 47 treated with volumetric modulated arc therapy (VMAT). Methods Treatment plan quality was evaluated in terms of target dose homogeneity and organs at risk (OAR), through the use of a set of dose metrics. These included the mean, maximum and minimum doses; the homogeneity and conformity indices for the target volumes; and a selection of dose coverage values that were relevant to each OAR. Statistical significance was evaluated using two-tailed Welch's T-tests. The Monte Carlo DICOM ToolKit software was adapted to permit the evaluation of dose metrics from DICOM data exported from a commercial radiotherapy treatment planning system. Results The 3DCRT treatment plans offered greater planning target volume dose homogeneity than the other two treatment modalities. The IMRT and VMAT plans offered greater dose reduction in the OAR: with increased compliance with recommended OAR dose constraints, compared to conventional 3DCRT treatments. When compared to each other, IMRT and VMAT did not provide significantly different treatment plan quality for like-sized tumour volumes. Conclusions This study indicates that IMRT and VMAT have provided similar dosimetric quality, which is superior to the dosimetric quality achieved with 3DCRT. PMID:26229621

  20. Retrospective evaluation of dosimetric quality for prostate carcinomas treated with 3D conformal, intensity modulated and volumetric modulated arc radiotherapy

    SciTech Connect

    Crowe, Scott B; Kairn, Tanya; Middlebrook, Nigel; Hill, Brendan; Christie, David R H; Knight, Richard T; Kenny, John; Langton, Christian M; Trapp, Jamie V

    2013-12-15

    This study examines and compares the dosimetric quality of radiotherapy treatment plans for prostate carcinoma across a cohort of 163 patients treated across five centres: 83 treated with three-dimensional conformal radiotherapy (3DCRT), 33 treated with intensity modulated radiotherapy (IMRT) and 47 treated with volumetric modulated arc therapy (VMAT). Treatment plan quality was evaluated in terms of target dose homogeneity and organs at risk (OAR), through the use of a set of dose metrics. These included the mean, maximum and minimum doses; the homogeneity and conformity indices for the target volumes; and a selection of dose coverage values that were relevant to each OAR. Statistical significance was evaluated using two-tailed Welch's T-tests. The Monte Carlo DICOM ToolKit software was adapted to permit the evaluation of dose metrics from DICOM data exported from a commercial radiotherapy treatment planning system. The 3DCRT treatment plans offered greater planning target volume dose homogeneity than the other two treatment modalities. The IMRT and VMAT plans offered greater dose reduction in the OAR: with increased compliance with recommended OAR dose constraints, compared to conventional 3DCRT treatments. When compared to each other, IMRT and VMAT did not provide significantly different treatment plan quality for like-sized tumour volumes. This study indicates that IMRT and VMAT have provided similar dosimetric quality, which is superior to the dosimetric quality achieved with 3DCRT.

  1. Plan-graph Based Heuristics for Conformant Probabilistic Planning

    NASA Technical Reports Server (NTRS)

    Ramakrishnan, Salesh; Pollack, Martha E.; Smith, David E.

    2004-01-01

    In this paper, we introduce plan-graph based heuristics to solve a variation of the conformant probabilistic planning (CPP) problem. In many real-world problems, it is the case that the sensors are unreliable or take too many resources to provide knowledge about the environment. These domains are better modeled as conformant planning problems. POMDP based techniques are currently the most successful approach for solving CPP but have the limitation of state- space explosion. Recent advances in deterministic and conformant planning have shown that plan-graphs can be used to enhance the performance significantly. We show that this enhancement can also be translated to CPP. We describe our process for developing the plan-graph heuristics and estimating the probability of a partial plan. We compare the performance of our planner PVHPOP when used with different heuristics. We also perform a comparison with a POMDP solver to show over a order of magnitude improvement in performance.

  2. Volumetric-modulated arc radiotherapy for pancreatic malignancies: Dosimetric comparison with sliding-window intensity-modulated radiotherapy and 3-dimensional conformal radiotherapy

    SciTech Connect

    Nabavizadeh, Nima Simeonova, Anna O.; Waller, Joseph G.; Romer, Jeanna L.; Monaco, Debra L.; Elliott, David A.; Tanyi, James A.; Fuss, Martin; Thomas, Charles R.; Holland, John M.

    2014-10-01

    Volumetric-modulated arc radiotherapy (VMAT) is an iteration of intensity-modulated radiotherapy (IMRT), both of which deliver highly conformal dose distributions. Studies have shown the superiority of VMAT and IMRT in comparison with 3-dimensional conformal radiotherapy (3D-CRT) in planning target volume (PTV) coverage and organs-at-risk (OARs) sparing. This is the first study examining the benefits of VMAT in pancreatic cancer for doses more than 55.8 Gy. A planning study comparing 3D-CRT, IMRT, and VMAT was performed in 20 patients with pancreatic cancer. Treatments were planned for a 25-fraction delivery of 45 Gy to a large field followed by a reduced-volume 8-fraction external beam boost to 59.4 Gy in total. OARs and PTV doses, conformality index (CI) deviations from 1.0, monitor units (MUs) delivered, and isodose volumes were compared. IMRT and VMAT CI deviations from 1.0 for the large-field and the boost plans were equivalent (large field: 0.032 and 0.046, respectively; boost: 0.042 and 0.037, respectively; p > 0.05 for all comparisons). Both IMRT and VMAT CI deviations from 1.0 were statistically superior to 3D-CRT (large field: 0.217, boost: 0.177; p < 0.05 for all comparisons). VMAT showed reduction of the mean dose to the boost PTV (VMAT: 61.4 Gy, IMRT: 62.4 Gy, and 3D-CRT: 62.3 Gy; p < 0.05). The mean number of MUs per fraction was significantly lower for VMAT for both the large-field and the boost plans. VMAT delivery time was less than 3 minutes compared with 8 minutes for IMRT. Although no statistically significant dose reduction to the OARs was identified when comparing VMAT with IMRT, VMAT showed a reduction in the volumes of the 100% isodose line for the large-field plans. Dose escalation to 59.4 Gy in pancreatic cancer is dosimetrically feasible with shorter treatment times, fewer MUs delivered, and comparable CIs for VMAT when compared with IMRT.

  3. Assessment of Extended-Field Radiotherapy for Stage IIIC Endometrial Cancer Using Three-Dimensional Conformal Radiotherapy, Intensity-Modulated Radiotherapy, and Helical Tomotherapy

    SciTech Connect

    Lian Jidong Mackenzie, Marc; Joseph, Kurian; Pervez, Nadeem; Dundas, George; Urtasun, Raul; Pearcey, Robert

    2008-03-01

    Purpose: To perform a dosimetric comparison of three-dimensional conformal radiotherapy (3D-CRT), intensity-modulated radiotherapy (IMRT), and helical tomotherapy (HT) plans for pelvic and para-aortic RT in postoperative endometrial cancer patients; and to evaluate the integral dose (ID) received by critical structures within the radiation fields. Methods and Materials: We selected 10 patients with Stage IIIC endometrial cancer. For each patient, three plans were created with 3D-CRT, IMRT, and HT. The IMRT and HT plans were both optimized to keep the mean dose to the planning target volume (PTV) the same as that with 3D-CRT. The dosimetry and ID for the critical structures were compared. A paired two-tailed Student t test was used for data analysis. Results: Compared with the 3D-CRT plans, the IMRT plans resulted in lower IDs in the organs at risk (OARs), ranging from -3.49% to -17.59%. The HT plans showed a similar result except that the ID for the bowel increased 0.27%. The IMRT and HT plans both increased the IDs to normal tissue (see and text for definition), pelvic bone, and spine (range, 3.31-19.7%). The IMRT and HT dosimetry showed superior PTV coverage and better OAR sparing than the 3D-CRT dosimetry. Compared directly with IMRT, HT showed similar PTV coverage, lower Ids, and a decreased dose to most OARs. Conclusion: Intensity-modulated RT and HT appear to achieve excellent PTV coverage and better sparing of OARs, but at the expense of increased IDs to normal tissue and skeleton. HT allows for additional improvement in dosimetry and sparing of most OARs.

  4. In vivo skin dose measurement in breast conformal radiotherapy

    PubMed Central

    Soleymanifard, Shokouhozaman; Noghreiyan, Atefeh Vejdani; Ghorbani, Mahdi; Jamali, Farideh; Davenport, David

    2016-01-01

    Aim of the study Accurate skin dose assessment is necessary during breast radiotherapy to assure that the skin dose is below the tolerance level and is sufficient to prevent tumour recurrence. The aim of the current study is to measure the skin dose and to evaluate the geometrical/anatomical parameters that affect it. Material and methods Forty patients were simulated by TIGRT treatment planning system and treated with two tangential fields of 6 MV photon beam. Wedge filters were used to homogenise dose distribution for 11 patients. Skin dose was measured by thermoluminescent dosimeters (TLD-100) and the effects of beam incident angle, thickness of irradiated region, and beam entry separation on the skin dose were analysed. Results Average skin dose in treatment course of 50 Gy to the clinical target volume (CTV) was 36.65 Gy. The corresponding dose values for patients who were treated with and without wedge filter were 35.65 and 37.20 Gy, respectively. It was determined that the beam angle affected the average skin dose while the thickness of the irradiated region and the beam entry separation did not affect dose. Since the skin dose measured in this study was lower than the amount required to prevent tumour recurrence, application of bolus material in part of the treatment course is suggested for post-mastectomy advanced breast radiotherapy. It is more important when wedge filters are applied to homogenize dose distribution. PMID:27358592

  5. Comparative dosimetric study of three-dimensional conformal, dynamic conformal arc, and intensity-modulated radiotherapy for brain tumor treatment using Novalis system

    SciTech Connect

    Ding Meisong . E-mail: Meisong.Ding@uchsc.edu; Newman, Francis M.S.; Kavanagh, Brian D.; Stuhr, Kelly M.S.; Johnson, Tim K.; Gaspar, Laurie E.

    2006-11-15

    Purpose: To investigate the dosimetric differences among three-dimensional conformal radiotherapy (3D-CRT), dynamic conformal arc therapy (DCAT), and intensity-modulated radiotherapy (IMRT) for brain tumor treatment. Methods and Materials: Fifteen patients treated with Novalis were selected. We performed 3D-CRT, DCAT, and IMRT plans for all patients. The margin for the planning target volume (PTV) was 1 mm, and the specific prescription dose was 90% for all plans. The target coverage at the prescription dose, conformity index (CI), and heterogeneity index were analyzed for all plans. Results: For small tumors (PTV {<=}2 cm{sup 3}), the three dosimetric parameters had approximate values for both 3D-CRT and DCAT plans. The CI for the IMRT plans was high. For medium tumors (PTV >2 to {<=}100 cm{sup 3}), the three plans were competitive with each other. The IMRT plans had a greater CI, better target coverage at the prescription dose, and a better heterogeneity index. For large tumors (PTV >100 cm{sup 3}), the IMRT plan had good target coverage at the prescription dose and heterogeneity index and approximate CI values as those in the 3D-CRT and DCAT plans. Conclusion: The results of our study have shown that DCAT is suitable for most cases in the treatment of brain tumors. For a small target, 3D-CRT is useful, and IMRT is not recommended. For larger tumors, IMRT is superior to 3D-CRT and very competitive in sparing critical structures, especially for big tumors.

  6. Planning tools for modulated electron radiotherapy

    SciTech Connect

    Surucu, Murat; Klein, Eric E.; Mamalui-Hunter, Maria; Mansur, David B.; Low, Daniel A.

    2010-05-15

    Purpose: To develop tools to plan modulated electron radiotherapy (MERT) and to compare the MERT plans to conventional or intensity modulated radiotherapy (IMRT) treatment plans. Methods: Monte Carlo dose calculations of electron fields shaped with the inherent photon multileaf collimators (MLCs) were investigated in this study. Treatment plans for four postmastectomy breast cancer patients were generated using MERT. The distances from the patient skin surfaces to the distal planning target volume surfaces were computed along the beam axis direction to determine the physical depth. Electron beam energies were selected to provide target coverage at these depths and energy bins were generated. A custom built MERT treatment planning graphical user interface (MERTgui) was used to shape the electron bins into deliverable electron segments. Monte Carlo dose distribution simulations were performed using the MLC-defined segments generated from the MERTgui. A custom built superposition gui was used to combine doses for each segment using relative weights and final MERT treatment plans were compared to the conventional or IMRT treatment plans. In addition, a demonstration of combined MERT and IMRT treatment plans was performed. Results: The MERT treatment plans provided acceptable target organ coverage in all cases. Relative to 3D conventional or IMRT treatment plans, the MERT plans predicted lower heart doses in all cases; average of the heart D{sub 20} of all plans was reduced from 14.1 to 3.3 Gy. The contralateral breast and contralateral lung doses decreased substantially with MERT planning compared to IMRT (on average, contralateral breast heart D{sub 20} was reduced from 8.7 to 0.7 Gy and contralateral lung D{sub 20} was reduced from 8.4 to 1.2 Gy with MERT). Ipsilateral lung D{sub 20} was lower with MERT than with the conventional plans (44.6 vs 29.2 Gy with MERT), but greater when compared against IMRT treatment plans (25.4 vs 28.9 Gy with MERT). A MERT and IMRT

  7. Comparison of Heart and Coronary Artery Doses Associated With Intensity-Modulated Radiotherapy Versus Three-Dimensional Conformal Radiotherapy for Distal Esophageal Cancer

    SciTech Connect

    Kole, Thomas P.; Aghayere, Osarhieme; Kwah, Jason; Yorke, Ellen D.; Goodman, Karyn A.

    2012-08-01

    Purpose: To compare heart and coronary artery radiation exposure using intensity-modulated radiotherapy (IMRT) vs. four-field three-dimensional conformal radiotherapy (3D-CRT) treatment plans for patients with distal esophageal cancer undergoing chemoradiation. Methods and Materials: Nineteen patients with distal esophageal cancers treated with IMRT from March 2007 to May 2008 were identified. All patients were treated to 50.4 Gy with five-field IMRT plans. Theoretical 3D-CRT plans with four-field beam arrangements were generated. Dose-volume histograms of the planning target volume, heart, right coronary artery, left coronary artery, and other critical normal tissues were compared between the IMRT and 3D-CRT plans, and selected parameters were statistically evaluated using the Wilcoxon rank-sum test. Results: Intensity-modulated radiotherapy treatment planning showed significant reduction (p < 0.05) in heart dose over 3D-CRT as assessed by average mean dose (22.9 vs. 28.2 Gy) and V30 (24.8% vs. 61.0%). There was also significant sparing of the right coronary artery (average mean dose, 23.8 Gy vs. 35.5 Gy), whereas the left coronary artery showed no significant improvement (mean dose, 11.2 Gy vs. 9.2 Gy), p = 0.11. There was no significant difference in percentage of total lung volume receiving at least 10, 15, or 20 Gy or in the mean lung dose between the planning methods. There were also no significant differences observed for the kidneys, liver, stomach, or spinal cord. Intensity-modulated radiotherapy achieved a significant improvement in target conformity as measured by the conformality index (ratio of total volume receiving 95% of prescription dose to planning target volume receiving 95% of prescription dose), with the mean conformality index reduced from 1.56 to 1.30 using IMRT. Conclusions: Treatment of patients with distal esophageal cancer using IMRT significantly decreases the exposure of the heart and right coronary artery when compared with 3D

  8. Toxicity of Three-Dimensional Conformal Radiotherapy for Accelerated Partial Breast Irradiation

    SciTech Connect

    Hepel, Jaroslaw T.; Tokita, Mari; MacAusland, Stephanie G.; Evans, Suzanne B.; Hiatt, Jessica R.; Price, Lori Lyn; DiPetrillo, Thomas; Wazer, David E.

    2009-12-01

    Purpose: To assess the incidence and severity of late normal tissue toxicity using three-dimensional conformal radiotherapy to deliver accelerated partial breast irradiation. Methods and Materials: A total of 60 patients were treated with three-dimensional conformal radiotherapy for accelerated partial breast irradiation. Treatment planning and delivery were in strict accordance with the technique and specified dose-volume constraints of the National Surgical Adjuvant Breast and Bowel Project B-39/Radiation Therapy Oncology Group 0413 protocol. Late toxicity was evaluated according to the Radiation Therapy Oncology Group grading schema. The cosmetic outcome was scored using the Harvard criteria. Univariate logistic regression analysis was performed to evaluate the correlation of dosimetric variables with outcome. Results: At a median follow-up of 15 months, moderate-to-severe late toxicity developed in 10% of patients. The most pronounced late toxicity was subcutaneous fibrosis: 25% Grade 2-4 and 8.3% Grade 3-4. The modified planning tumor volume/whole breast volume ratio, ratio of the volume of breast tissue receiving 5%, 20%, 50%, and 80% of the prescription dose to the whole breast volume, and maximal dose within the breast correlated with the development of fibrosis (p = .10, p = .03, p = .04, p = .06, p = .09, and p = .046, respectively). The overall cosmetic outcome was good to excellent in 81.7%, fair in 11.7%, and poor in 6.7%. The presence of subcutaneous fibrosis, modified planning tumor volume/whole breast volume ratio, ratio of the volume of breast tissue receiving 5% and 20% of the prescription dose to the whole breast volume, and pathologic specimen volume correlated with the risk of a fair/poor cosmetic outcome (p < .001, p = .02, p = .05, p = .04, p = .01, respectively). Conclusion: The three-dimensional conformal radiotherapy technique for accelerated partial breast irradiation as specified in the National Surgical Adjuvant Breast and Bowel Project

  9. Intensity-Modulated vs. Conformal Radiotherapy of Parotid Gland Tumors: Potential Impact on Hearing Loss

    SciTech Connect

    Lamers-Kuijper, E. Schwarz, M.; Rasch, C.; Mijnheer, B.

    2007-01-01

    In 3-dimensional (3D) conformal radiotherapy of parotid gland tumors, little effort is made to avoid the auditory system or the oral cavity. Damage may occur when the ear is located inside the treatment field. The purpose of this study was to design and evaluate an intensity-modulation radiotherapy (IMRT) class solution, and to compare this technique to a 3D conformal approach with respect to hearing loss. Twenty patients with parotid gland cancer were retrospectively planned with 2 different techniques using the original planning target volume (PTV). First, a conventional technique using a wedged beam pair was applied, yielding a dose distribution conformal to the shape of the PTV. Next, an IMRT technique using a fluence map optimization with predefined constraints was designed. A dose of 66 Gy in the PTV was given at the International Commission on Radiation Units and Measures (ICRU) dose prescription point. Dose-volume histograms of the PTV and organs at risk (OARs), such as auditory system, oral cavity, and spinal cord, were compared. The dose in the OARs was lower in the IMRT plans. The mean volume of the middle ear receiving a dose higher than 50 Gy decreased from 66.5% to 33.4%. The mean dose in the oral cavity decreased from 19.4 Gy to 16.6 Gy. The auditory system can be spared if the distance between the inner ear and the PTV is 0.6 cm or larger, and if the overlap between the middle ear and the PTV is smaller than 10%. The maximum dose in the spinal cord was below 40 Gy in all treatment plans. The mean volume of the PTV receiving less than 95% of the prescribed dose increased in the IMRT plan slightly from 3.3% to 4.3 % (p = 0.01). The mean volume receiving more than 107% increased from 0.9% to 2.5% (p = 0.02). It can be concluded that the auditory system, as well as the oral cavity, can be spared with IMRT, but at the cost of a slightly larger dose inhomogeneity in the PTV. The IMRT technique can therefore, in most cases, be recommended as the treatment

  10. High-Dose Conformal Radiotherapy for Patients With Stage III Non-Small-Cell Lung Carcinoma

    SciTech Connect

    Nakayama, Hidetsugu; Satoh, Hiroaki; Kurishima, Koichi; Ishikawa, Hiroichi; Tokuuye, Koichi

    2010-11-01

    Purpose: To determine the effectiveness of high-dose conformal radiotherapy to the involved field for patients with Stage III non-small-cell lung cancer (NSCLC). Methods and Materials: Between May 1999 and April 2006, a total of 100 consecutive patients with inoperable Stage IIIA or IIIB NSCLC with a performance score of 0 to 2 and treatment by radical radiotherapy combined with chemotherapy were included. Up to August 2002, 33 patients underwent conventional radiotherapy of 56 Gy to 66 Gy using anteroposterior opposite ports to the primary tumor and elective lymph nodes (conventional group). After September 2002, the remaining 67 patients underwent high-dose radiotherapy of 66 Gy to 84 Gy to the involved volume with three-dimensional (3-D) conformal radiotherapy (conformal group). Results: The median survival was 13.2 months (95% confidence interval [CI], 7.5-18.5 months) in the conventional group and 17.3 months (95% CI, 10.7- 24.0 months) in the conformal group. The overall survival at 3 years were 9.1% (95% CI, -0.7-18.9%) in the conventional group and 31.0% (95% CI, 18.9-43.1%) in the conformal group; the conformal group had a significantly better overall survival (p < 0.05). The radiotherapy method (hazard ratio = 0.55, p < 0.05) and performance status (hazard ratio = 1.48, p < 0.05) were shown to be statistically significant independent prognostic factors. Conclusions: Based on the practical experience reported here, 3-D conformal radiotherapy allowed dose escalation without excessive toxicity, and may improve overall survival rates for patients with Stage III NSCLC.

  11. Biological dose volume histograms during conformal hypofractionated accelerated radiotherapy for prostate cancer

    SciTech Connect

    Koukourakis, Michael I.; Abatzoglou, Ioannis; Touloupidis, Stavros; Manavis, Ioannis

    2007-01-15

    Radiobiological data suggest that prostate cancer has a low {alpha}/{beta} ratio. Large radiotherapy fractions may, therefore, prove more efficacious than standard radiotherapy, while radiotherapy acceleration should further improve control rates. This study describes the radiobiology of a conformal hypofractionated accelerated radiotherapy scheme for the treatment of high risk prostate cancer. Anteroposterior fields to the pelvis deliver a daily dose of 2.7 Gy, while lateral fields confined to the prostate and seminal vesicles deliver an additional daily dose of 0.7 Gy. Radiotherapy is accomplished within 19 days (15 fractions). Dose volume histograms, calculated for tissue specific {alpha}/{beta} ratios and time factors, predict a high biological dose to the prostate and seminal vesicles (77-93 Gy). The biological dose to normal pelvic tissues is maintained at standard levels. Radiobiological dosimetry suggests that, using hypofractionated and accelerated radiotherapy, high biological radiation dose can be given to the prostate without overdosing normal tissues.

  12. Dose masking feature for BNCT radiotherapy planning

    DOEpatents

    Cook, Jeremy L.; Wessol, Daniel E.; Wheeler, Floyd J.

    2000-01-01

    A system for displaying an accurate model of isodoses to be used in radiotherapy so that appropriate planning can be performed prior to actual treatment on a patient. The nature of the simulation of the radiotherapy planning for BNCT and Fast Neutron Therapy, etc., requires that the doses be computed in the entire volume. The "entire volume" includes the patient and beam geometries as well as the air spaces in between. Isodoses derived from the computed doses will therefore extend into the air regions between the patient and beam geometries and thus depict the unrealistic possibility that radiation deposition occurs in regions containing no physical media. This problem is solved by computing the doses for the entire geometry and then masking the physical and air regions along with the isodose contours superimposed over the patient image at the corresponding plane. The user is thus able to mask out (remove) the contour lines from the unwanted areas of the image by selecting the appropriate contour masking region from the raster image.

  13. Magnetic Resonance Imaging in Postprostatectomy Radiotherapy Planning

    SciTech Connect

    Sefrova, Jana; Odrazka, Karel; Paluska, Petr; Belobradek, Zdenek; Brodak, Milos; Dolezel, Martin; Prosvic, Petr; Macingova, Zuzana; Vosmik, Milan; Hoffmann, Petr; Louda, Miroslav; Nejedla, Anna

    2012-02-01

    Purpose: To investigate whether the use of magnetic resonance imaging (MRI) in prostate bed treatment planning could influence definition of the clinical target volume (CTV) and organs at risk. Methods and Materials: A total of 21 consecutive patients referred for prostate bed radiotherapy were included in the present retrospective study. The CTV was delineated according to the European Organization for Research and Treatment of Cancer recommendations on computed tomography (CT) and T{sub 1}-weighted (T{sub 1}w) and T{sub 2}-weighted (T{sub 2}w) MRI. The CTV magnitude, agreement, and spatial differences were evaluated on the planning CT scan after registration with the MRI scans. Results: The CTV was significantly reduced on the T{sub 1}w and T{sub 2}w MRI scans (13% and 9%, respectively) compared with the CT scans. The urinary bladder was drawn smaller on the CT scans and the rectum was smaller on the MRI scans. On T{sub 1}w MRI, the rectum and urinary bladder were delineated larger than on T{sub 2}w MRI. Minimal agreement was observed between the CT and T{sub 2}w images. The main spatial differences were measured in the superior and superolateral directions in which the CTV on the MRI scans was 1.8-2.9 mm smaller. In the posterior and inferior border, no difference was seen between the CT and T{sub 1}w MRI scans. On the T{sub 2}w MRI scans, the CTV was larger in these directions (by 1.3 and 1.7 mm, respectively). Conclusions: The use of MRI in postprostatectomy radiotherapy planning resulted in a reduction of the CTV. The main differences were found in the superior part of the prostate bed. We believe T{sub 2}w MRI enables more precise definition of prostate bed CTV than conventional planning CT.

  14. Comparison of Three-Dimensional (3D) Conformal Proton Radiotherapy (RT), 3D Conformal Photon RT, and Intensity-Modulated RT for Retroperitoneal and Intra-Abdominal Sarcomas

    SciTech Connect

    Swanson, Erika L.; Indelicato, Daniel J.; Louis, Debbie; Flampouri, Stella; Li, Zuofeng; Morris, Christopher G.; Paryani, Nitesh; Slopsema, Roelf

    2012-08-01

    Purpose: To compare three-dimensional conformal proton radiotherapy (3DCPT), intensity-modulated photon radiotherapy (IMRT), and 3D conformal photon radiotherapy (3DCRT) to predict the optimal RT technique for retroperitoneal sarcomas. Methods and Materials: 3DCRT, IMRT, and 3DCPT plans were created for treating eight patients with retroperitoneal or intra-abdominal sarcomas. The clinical target volume (CTV) included the gross tumor plus a 2-cm margin, limited by bone and intact fascial planes. For photon plans, the planning target volume (PTV) included a uniform expansion of 5 mm. For the proton plans, the PTV was nonuniform and beam-specific. The prescription dose was 50.4 Gy/Cobalt gray equivalent CGE. Plans were normalized so that >95% of the CTV received 100% of the dose. Results: The CTV was covered adequately by all techniques. The median conformity index was 0.69 for 3DCPT, 0.75 for IMRT, and 0.51 for 3DCRT. The median inhomogeneity coefficient was 0.062 for 3DCPT, 0.066 for IMRT, and 0.073 for 3DCRT. The bowel median volume receiving 15 Gy (V15) was 16.4% for 3DCPT, 52.2% for IMRT, and 66.1% for 3DCRT. The bowel median V45 was 6.3% for 3DCPT, 4.7% for IMRT, and 15.6% for 3DCRT. The median ipsilateral mean kidney dose was 22.5 CGE for 3DCPT, 34.1 Gy for IMRT, and 37.8 Gy for 3DCRT. The median contralateral mean kidney dose was 0 CGE for 3DCPT, 6.4 Gy for IMRT, and 11 Gy for 3DCRT. The median contralateral kidney V5 was 0% for 3DCPT, 49.9% for IMRT, and 99.7% for 3DCRT. Regardless of technique, the median mean liver dose was <30 Gy, and the median cord V50 was 0%. The median integral dose was 126 J for 3DCPT, 400 J for IMRT, and 432 J for 3DCRT. Conclusions: IMRT and 3DCPT result in plans that are more conformal and homogenous than 3DCRT. Based on Quantitative Analysis of Normal Tissue Effects in Clinic benchmarks, the dosimetric advantage of proton therapy may be less gastrointestinal and genitourinary toxicity.

  15. Automated radiotherapy treatment plan integrity verification

    SciTech Connect

    Yang Deshan; Moore, Kevin L.

    2012-03-15

    Purpose: In our clinic, physicists spend from 15 to 60 min to verify the physical and dosimetric integrity of radiotherapy plans before presentation to radiation oncology physicians for approval. The purpose of this study was to design and implement a framework to automate as many elements of this quality control (QC) step as possible. Methods: A comprehensive computer application was developed to carry out a majority of these verification tasks in the Philips PINNACLE treatment planning system (TPS). This QC tool functions based on both PINNACLE scripting elements and PERL sub-routines. The core of this technique is the method of dynamic scripting, which involves a PERL programming module that is flexible and powerful for treatment plan data handling. Run-time plan data are collected, saved into temporary files, and analyzed against standard values and predefined logical rules. The results were summarized in a hypertext markup language (HTML) report that is displayed to the user. Results: This tool has been in clinical use for over a year. The occurrence frequency of technical problems, which would cause delays and suboptimal plans, has been reduced since clinical implementation. Conclusions: In addition to drastically reducing the set of human-driven logical comparisons, this QC tool also accomplished some tasks that are otherwise either quite laborious or impractical for humans to verify, e.g., identifying conflicts amongst IMRT optimization objectives.

  16. Dosimetry audit of radiotherapy treatment planning systems.

    PubMed

    Bulski, Wojciech; Chełmiński, Krzysztof; Rostkowska, Joanna

    2015-07-01

    In radiotherapy Treatment Planning Systems (TPS) various calculation algorithms are used. The accuracy of dose calculations has to be verified. Numerous phantom types, detectors and measurement methodologies are proposed to verify the TPS calculations with dosimetric measurements. A heterogeneous slab phantom has been designed within a Coordinated Research Project (CRP) of the IAEA. The heterogeneous phantom was developed in the frame of the IAEA CRP. The phantom consists of frame slabs made with polystyrene and exchangeable inhomogeneity slabs equivalent to bone or lung tissue. Special inserts allow to position thermoluminescent dosimeters (TLD) capsules within the polystyrene slabs below the bone or lung equivalent slabs and also within the lung equivalent material. Additionally, there are inserts that allow to position films or ionisation chamber in the phantom. Ten Polish radiotherapy centres (of 30 in total) were audited during on-site visits. Six different TPSs and five calculation algorithms were examined in the presence of inhomogeneities. Generally, most of the results from TLD were within 5 % tolerance. Differences between doses calculated by TPSs and measured with TLD did not exceed 4 % for bone and polystyrene equivalent materials. Under the lung equivalent material, on the beam axis the differences were lower than 5 %, whereas inside the lung equivalent material, off the beam axis, in some cases they were of around 7 %. The TLD results were confirmed with the ionisation chamber measurements. The comparison results of the calculations and the measurements allow to detect limitations of TPS calculation algorithms. The audits performed with the use of heterogeneous phantom and TLD seem to be an effective tool for detecting the limitations in the TPS performance or beam configuration errors at audited radiotherapy departments. PMID:25848119

  17. Esophageal perforation during or after conformal radiotherapy for esophageal carcinoma

    PubMed Central

    Chen, Hai-yan; Ma, Xiu-mei; Ye, Ming; Hou, Yan-li; Xie, Hua-Ying; Bai, Yong-rui

    2014-01-01

    The aim of this study was to analyze the risk factors and prognosis for patients with esophageal perforation occurring during or after radiotherapy for esophageal carcinoma. We retrospectively analyzed 322 patients with esophageal carcinoma. These patients received radiotherapy for unresectable esophageal tumors, residual tumors after operation, or local recurrence. Of these, 12 had radiotherapy to the esophagus before being admitted, 68 patients had concurrent chemoradiotherapy (CRT), and 18 patients had esophageal perforation after RT (5.8%). Covered self-expandable metallic stents were placed in 11 patients. Two patients continued RT after stenting and control of infection; one of these suffered a new perforation, and the other had a massive hemorrhage. The median overall survival was 2 months (0–3 months) compared with 17 months in the non-perforation group. In univariate analysis, the Karnofsky performance status (KPS) being ≤70, age younger than 60, T4 stage, a second course of radiotherapy to the esophagus, extracapsular lymph nodes (LN) involving the esophagus, a total dose >100 Gy (biologically effective dose−10), and CRT were risk factors for perforation. In multivariate analysis, age younger than 60, extracapsular LN involving the esophagus, T4 stage, and a second course of radiotherapy to the esophagus were risk factors. In conclusion, patients with T4 stage, extracapsular LN involving the esophagus, and those receiving a second course of RT should be given particular care to avoid perforation. The prognosis after perforation was poor. PMID:24914102

  18. Cardiac Exposure in the Dynamic Conformal Arc Therapy, Intensity-Modulated Radiotherapy and Volumetric Modulated Arc Therapy of Lung Cancer

    PubMed Central

    Ming, Xin; Feng, Yuanming; Liu, Huan; Zhang, Ying; Zhou, Li; Deng, Jun

    2015-01-01

    Purpose To retrospectively evaluate the cardiac exposure in three cohorts of lung cancer patients treated with dynamic conformal arc therapy (DCAT), intensity-modulated radiotherapy (IMRT), or volumetric modulated arc therapy (VMAT) at our institution in the past seven years. Methods and Materials A total of 140 lung cancer patients were included in this institutional review board approved study: 25 treated with DCAT, 70 with IMRT and 45 with VMAT. All plans were generated in a same commercial treatment planning system and have been clinically accepted and delivered. The dose distribution to the heart and the effects of tumor laterality, the irradiated heart volume and the beam-to-heart distance on the cardiac exposure were investigated. Results The mean dose to the heart among all 140 plans was 4.5 Gy. Specifically, the heart received on average 2.3, 5.2 and 4.6 Gy in the DCAT, IMRT and VMAT plans, respectively. The mean heart doses for the left and right lung tumors were 4.1 and 4.8 Gy, respectively. No patients died with evidence of cardiac disease. Three patients (2%) with preexisting cardiac condition developed cardiac disease after treatment. Furthermore, the cardiac exposure was found to increase linearly with the irradiated heart volume while decreasing exponentially with the beam-to-heart distance. Conclusions Compared to old technologies for lung cancer treatment, modern radiotherapy treatment modalities demonstrated better heart sparing. But the heart dose in lung cancer radiotherapy is still higher than that in the radiotherapy of breast cancer and Hodgkin’s disease where cardiac complications have been extensively studied. With strong correlations of mean heart dose with beam-to-heart distance and irradiated heart volume, cautions should be exercised to avoid long-term cardiac toxicity in the lung cancer patients undergoing radiotherapy. PMID:26630566

  19. Optimization approaches for planning external beam radiotherapy

    NASA Astrophysics Data System (ADS)

    Gozbasi, Halil Ozan

    Cancer begins when cells grow out of control as a result of damage to their DNA. These abnormal cells can invade healthy tissue and form tumors in various parts of the body. Chemotherapy, immunotherapy, surgery and radiotherapy are the most common treatment methods for cancer. According to American Cancer Society about half of the cancer patients receive a form of radiation therapy at some stage. External beam radiotherapy is delivered from outside the body and aimed at cancer cells to damage their DNA making them unable to divide and reproduce. The beams travel through the body and may damage nearby healthy tissue unless carefully planned. Therefore, the goal of treatment plan optimization is to find the best system parameters to deliver sufficient dose to target structures while avoiding damage to healthy tissue. This thesis investigates optimization approaches for two external beam radiation therapy techniques: Intensity-Modulated Radiation Therapy (IMRT) and Volumetric-Modulated Arc Therapy (VMAT). We develop automated treatment planning technology for IMRT that produces several high-quality treatment plans satisfying provided clinical requirements in a single invocation and without human guidance. A novel bi-criteria scoring based beam selection algorithm is part of the planning system and produces better plans compared to those produced using a well-known scoring-based algorithm. Our algorithm is very efficient and finds the beam configuration at least ten times faster than an exact integer programming approach. Solution times range from 2 minutes to 15 minutes which is clinically acceptable. With certain cancers, especially lung cancer, a patient's anatomy changes during treatment. These anatomical changes need to be considered in treatment planning. Fortunately, recent advances in imaging technology can provide multiple images of the treatment region taken at different points of the breathing cycle, and deformable image registration algorithms can

  20. Carotid-Sparing TomoHelical 3-Dimensional Conformal Radiotherapy for Early Glottic Cancer

    PubMed Central

    Hong, Chae-Seon; Oh, Dongryul; Ju, Sang Gyu; Ahn, Yong Chan; Noh, Jae Myoung; Chung, Kwangzoo; Kim, Jin Sung; Suh, Tae-Suk

    2016-01-01

    Purpose The purpose of this study was to investigate the dosimetric benefits and treatment efficiency of carotid-sparing TomoHelical 3-dimensional conformal radiotherapy (TH-3DCRT) for early glottic cancer. Materials and Methods Ten early-stage (T1N0M0) glottic squamous cell carcinoma patients were simulated, based on computed tomography scans. Two-field 3DCRT (2F-3DCRT), 3-field intensity-modulated radiation therapy (3F-IMRT), TomoHelical-IMRT (TH-IMRT), and TH-3DCRT plans were generated with a 67.5-Gy total prescription dose to the planning target volume (PTV) for each patient. In order to evaluate the plan quality, dosimetric characteristics were compared in terms of conformity index (CI) and homogeneity index (HI) for PTV, dose to the carotid arteries, and maximum dose to the spinal cord. Treatment planning and delivery times were compared to evaluate treatment efficiency. Results The median CI was substantially better for the 3F-IMRT (0.65), TH-IMRT (0.64), and TH-3DCRT (0.63) plans, compared to the 2F-3DCRT plan (0.32). PTV HI was slightly better for TH-3DCRT and TH-IMRT (1.05) compared to 2F-3DCRT (1.06) and 3F-IMRT (1.09). TH-3DCRT, 3F-IMRT, and TH-IMRT showed an excellent carotid sparing capability compared to 2F-3DCRT (p < 0.05). For all plans, the maximum dose to the spinal cord was < 45 Gy. The median treatment planning times for 2F-3DCRT (5.85 minutes) and TH-3DCRT (7.10 minutes) were much lower than those for 3F-IMRT (45.48 minutes) and TH-IMRT (35.30 minutes). The delivery times for 2F-3DCRT (2.06 minutes) and 3F-IMRT (2.48 minutes) were slightly lower than those for TH-IMRT (2.90 minutes) and TH-3DCRT (2.86 minutes). Conclusion TH-3DCRT showed excellent carotid-sparing capability, while offering high efficiency and maintaining good PTV coverage. PMID:25761477

  1. Dosimetric Evaluation of a Simple Planning Technique for Improving Intensity-Modulated Radiotherapy for Nasopharyngeal Cancer

    PubMed Central

    Xie, Wen-Jia; Xie, Liang-Xi

    2015-01-01

    Purpose To evaluate the dosimetric outcomes of a simple planning technique for improving intensity-modulated radiotherapy (IMRT) for nasopharyngeal cancer (NPC). Methods For 39 NPC cases, generally acceptable original plans were generated and were improved by the two planning techniques, respectively: (1) a basal-dose-compensation (BDC) technique, in which the treatment plans were re-optimized based on the original plans; (2) a local-dose-control (LDC) technique, in which the original plans were re-optimized with constraints for hot and cold spots. The BDC, original, and LDC plans were then compared regarding homogeneity index (HI) and conformity index (CI) of planning target volumes (PTVs), organ-at-risk (OAR) sparing and monitor units (MUs) per fraction. The whole planning times were also compared between the BDC and LDC plans. Results The BDC plans had superior HIs / CIs, by 13-24% / 3-243%, respectively, over the original plans. Compared to the LDC plans, the BDC plans provided better HIs only for PTVnx (the PTV of nasopharyngeal primary tumor) by 11% and better CIs for all PTVs by 2-134%. The BDC technique spared most OARs, by 1-9%. The average MUs of the BDC, original, and LDC plans were 2149, 2068 and 2179, respectively. The average whole planning times were 48 and 69 minutes for the BDC and LDC plans, respectively. Conclusions For the IMRT of nasopharyngeal cancer, the BDC planning technique can improve target dose homogeneity, conformity and OAR sparing, with better planning efficiency. PMID:26132167

  2. Three-Dimensional Conformal Simultaneously Integrated Boost Technique for Breast-Conserving Radiotherapy

    SciTech Connect

    Laan, Hans Paul van der

    2007-07-15

    Purpose: To compare the target coverage and normal tissue dose with the simultaneously integrated boost (SIB) and the sequential boost technique in breast cancer, and to evaluate the incidence of acute skin toxicity in patients treated with the SIB technique. Methods and Materials: Thirty patients with early-stage left-sided breast cancer underwent breast-conserving radiotherapy using the SIB technique. The breast and boost planning target volumes (PTVs) were treated simultaneously (i.e., for each fraction, the breast and boost PTVs received 1.81 Gy and 2.3 Gy, respectively). Three-dimensional conformal beams with wedges were shaped and weighted using forward planning. Dose-volume histograms of the PTVs and organs at risk with the SIB technique, 28 x (1.81 + 0.49 Gy), were compared with those for the sequential boost technique, 25 x 2 Gy + 8 x 2 Gy. Acute skin toxicity was evaluated for 90 patients treated with the SIB technique according to Common Terminology Criteria for Adverse Events, version 3.0. Results: PTV coverage was adequate with both techniques. With SIB, more efficiently shaped boost beams resulted in smaller irradiated volumes. The mean volume receiving {>=}107% of the breast dose was reduced by 20%, the mean volume outside the boost PTV receiving {>=}95% of the boost dose was reduced by 54%, and the mean heart and lung dose were reduced by 10%. Of the evaluated patients, 32.2% had Grade 2 or worse toxicity. Conclusion: The SIB technique is proposed for standard use in breast-conserving radiotherapy because of its dose-limiting capabilities, easy implementation, reduced number of treatment fractions, and relatively low incidence of acute skin toxicity.

  3. A Comparison of Helical Intensity-Modulated Radiotherapy, Intensity-Modulated Radiotherapy, and 3D-Conformal Radiation Therapy for Pancreatic Cancer

    SciTech Connect

    Poppe, Matthew M.; Narra, Venkat; Yue, Ning J.; Zhou Jinghao; Nelson, Carl; Jabbour, Salma K.

    2011-01-01

    We assessed dosimetric differences in pancreatic cancer radiotherapy via helical intensity-modulated radiotherapy (HIMRT), linac-based IMRT, and 3D-conformal radiation therapy (3D-CRT) with regard to successful plan acceptance and dose to critical organs. Dosimetric analysis was performed in 16 pancreatic cases that were planned to 54 Gy; both post-pancreaticoduodenectomy (n = 8) and unresected (n = 8) cases were compared. Without volume modification, plans met constraints 75% of the time with HIMRT and IMRT and 13% with 3D-CRT. There was no statistically significantly improvement with HIMRT over conventional IMRT in reducing liver V35, stomach V45, or bowel V45. HIMRT offers improved planning target volume (PTV) dose homogeneity compared with IMRT, averaging a lower maximum dose and higher volume receiving the prescription dose (D100). HIMRT showed an increased mean dose over IMRT to bowel and liver. Both HIMRT and IMRT offer a statistically significant improvement over 3D-CRT in lowering dose to liver, stomach, and bowel. The results were similar for both unresected and resected patients. In pancreatic cancer, HIMRT offers improved dose homogeneity over conventional IMRT and several significant benefits to 3D-CRT. Factors to consider before incorporating IMRT into pancreatic cancer therapy are respiratory motion, dose inhomogeneity, and mean dose.

  4. Limited Advantages of Intensity-Modulated Radiotherapy Over 3D Conformal Radiation Therapy in the Adjuvant Management of Gastric Cancer

    SciTech Connect

    Alani, Shlomo; Soyfer, Viacheslav; Strauss, Natan; Schifter, Dan; Corn, Benjamin W.

    2009-06-01

    Purpose: Although chemoradiotherapy was considered the standard adjuvant treatment for gastric cancer, a recent Phase III trial (Medical Research Council Adjuvant Gastric Infusional Chemotherapy [MAGIC]) did not include radiotherapy in the randomization scheme because it was considered expendable. Given radiotherapy's potential, efforts needed to be made to optimize its use for treating gastric cancer. We assessed whether intensity-modulated radiotherapy (IMRT) could improve upon our published results in patients treated with three-dimensional (3D) conformal therapy. Methods and Materials: Fourteen patients with adenocarcinoma of the stomach were treated with adjuvant chemoradiotherapy using a noncoplanar four-field arrangement. Subsequently, a nine-field IMRT plan was designed using a CMS Xio IMRT version 4.3.3 module. Two IMRT beam arrangements were evaluated: beam arrangement 1 consisted of gantry angles of 0 deg., 53 deg., 107 deg., 158 deg., 204 deg., 255 deg., and 306 deg.. Beam arrangement 2 consisted of gantry angles of 30 deg., 90 deg., 315 deg., and 345 deg.; a gantry angle of 320 deg./couch, 30 deg.; and a gantry angle of 35{sup o}/couch, 312{sup o}. Both the target volume coverage and the dose deposition in adjacent critical organs were assessed in the plans. Dose-volume histograms were generated for the clinical target volume, kidneys, spine, and liver. Results: Comparison of the clinical target volumes revealed satisfactory coverage by the 95% isodose envelope using either IMRT or 3D conformal therapy. However, IMRT was only marginally better than 3D conformal therapy at protecting the spine and kidneys from radiation. Conclusions: IMRT confers only a marginal benefit in the adjuvant treatment of gastric cancer and should be used only in the small subset of patients with risk factors for kidney disease or those with a preexisting nephropathy.

  5. Skin-sparing Helical Tomotherapy vs 3D-conformal Radiotherapy for Adjuvant Breast Radiotherapy: In Vivo Skin Dosimetry Study

    SciTech Connect

    Capelle, Lisa; Warkentin, Heather; MacKenzie, Marc; Joseph, Kurian; Gabos, Zsolt; Pervez, Nadeem; Tankel, Keith; Chafe, Susan; Amanie, John; Ghosh, Sunita; Parliament, Matthew; Abdulkarim, Bassam

    2012-08-01

    Purpose: We investigated whether treatment-planning system (TPS)-calculated dose accurately reflects skin dose received for patients receiving adjuvant breast radiotherapy (RT) with standard three-dimensional conformal RT (3D-CRT) or skin-sparing helical tomotherapy (HT). Methods and Materials: Fifty patients enrolled in a randomized controlled trial investigating acute skin toxicity from adjuvant breast RT with 3D-CRT compared to skin-sparing HT, where a 5-mm strip of ipsilateral breast skin was spared. Thermoluminescent dosimetry or optically stimulated luminescence measurements were made in multiple locations and were compared to TPS-calculated doses. Skin dosimetric parameters and acute skin toxicity were recorded in these patients. Results: With HT there was a significant correlation between calculated and measured dose in the medial and lateral ipsilateral breast (r = 0.67, P<.001; r = 0.44, P=.03, respectively) and the medial and central contralateral breast (r = 0.73, P<.001; r = 0.88, P<.001, respectively). With 3D-CRT there was a significant correlation in the medial and lateral ipsilateral breast (r = 0.45, P=.03; r = 0.68, P<.001, respectively); the medial and central contralateral breast (r = 0.62, P=.001; r = 0.86, P<.001, respectively); and the mid neck (r = 0.42, P=.04, respectively). On average, HT-calculated dose overestimated the measured dose by 14%; 3D-CRT underestimated the dose by 0.4%. There was a borderline association between highest measured skin dose and moist desquamation (P=.05). Skin-sparing HT had greater skin homogeneity (homogeneity index of 1.39 vs 1.65, respectively; P=.005) than 3D-CRT plans. HT plans had a lower skin{sub V50} (1.4% vs 5.9%, respectively; P=.001) but higher skin{sub V40} and skin{sub V30} (71.7% vs 64.0%, P=.02; and 99.0% vs 93.8%, P=.001, respectively) than 3D-CRT plans. Conclusion: The 3D-CRT TPS more accurately reflected skin dose than the HT TPS, which tended to overestimate dose received by 14% in patients

  6. Superiority of helical tomotherapy on liver sparing and dose escalation in hepatocellular carcinoma: a comparison study of three-dimensional conformal radiotherapy and intensity-modulated radiotherapy

    PubMed Central

    Zhao, Qianqian; Wang, Renben; Zhu, Jian; Jin, Linzhi; Zhu, Kunli; Xu, Xiaoqing; Feng, Rui; Jiang, Shumei; Qi, Zhonghua; Yin, Yong

    2016-01-01

    Background and purpose To compare the difference of liver sparing and dose escalation between three-dimensional conformal radiotherapy (3DCRT), intensity-modulated radiotherapy (IMRT), and helical tomotherapy (HT) for hepatocellular carcinoma. Patients and methods Sixteen unresectable HCC patients were enrolled in this study. First, some evaluation factors of 3DCRT, IMRT, and HT plans were calculated with prescription dose at 50 Gy/25 fractions. Then, the doses were increased using HT or IMRT independently until either the plans reached 70 Gy or any normal tissue reached the dose limit according to quantitative analysis of normal tissue effects in the clinic criteria. Results The conformal index of 3DCRT was lower than that of IMRT (P<0.001) or HT (P<0.001), and the homogeneity index of 3DCRT was higher than that of IMRT (P<0.001) or HT (P<0.001). HT took the longest treatment time (P<0.001). For V50% (fraction of normal liver treated to at least 50% of the isocenter dose) of the normal liver, there was a significant difference: 3DCRT > IMRT > HT (P<0.001). HT had a lower Dmean (mean dose) and V20 (Vn, the percentage of organ volume receiving ≥n Gy) of liver compared with 3DCRT (P=0.005 and P=0.005, respectively) or IMRT (P=0.508 and P=0.007, respectively). Dmean of nontarget normal liver and V30 of liver were higher for 3DCRT than IMRT (P=0.005 and P=0.005, respectively) or HT (P=0.005 and P=0.005, respectively). Seven patients in IMRT (43.75%) and nine patients in HT (56.25%) reached the isodose 70 Gy, meeting the dose limit of the organs at risk. Conclusion HT may provide significantly better liver sparing and allow more patients to achieve higher prescription dose in HCC radiotherapy. PMID:27445485

  7. A single plan solution to chest wall radiotherapy with bolus?

    PubMed Central

    Ordonez-Sanz, C; Bowles, S; Hirst, A

    2014-01-01

    Objective: Radiotherapy treatments of post-mastectomy chest walls are complex, requiring treatment close to skin, necessitating bolus use. Commonly used 5- and 10-mm-thick boluses develop full skin dose, needing removal for the latter half of treatment and requiring two treatment plans to be generated. Can a thinner bolus be used for all treatment fractions, requiring only one plan? Methods: Investigation of doses received using (A) a half-time 10-mm-thick Vaseline® bolus (current situation); (B) a brass mesh (Whiting & Davis, Attleboro Falls, MA) and (C) 3- and 5-mm Superflab™ (Mick Radio-Nuclear Instruments, Mount Vernon, NY) for 6 and 15 MV. Dosimetric measurements in Barts WT1 solid water and an anthropomorphic phantom, using ionization chambers and thermoluminescent dosemeters, were used to study the effect of different bolus regimes on the photon depth–dose curves (DDCs) and skin doses. Results: Measured skin doses for the current 10-mm-thick Vaseline bolus, brass mesh and 3-mm bolus were compared (5 mm bolus has been rejected). The brass mesh has the least effect on the DDC, with changes <0.7% for depths greater than dmax. Brass mesh conforms superiorly to skin surfaces. Measurements on an anthropomorphic phantom demonstrate an increased skin dose compared with our current treatment protocol. Conclusion: Brass mesh has the smallest effect on the DDC, whilst sufficiently increasing surface dose. It can be removed at any fraction, based on a clinical decision, without the need for generating a new plan. Treating with one plan significantly reduces planning times. Advances in knowledge: Quantification of skin doses required and achieved from wax-on/wax-off treatment compared with alternative available breast boluses. PMID:24646288

  8. Conkiss: Conformal Kidneys Sparing 3D Noncoplanar Radiotherapy Treatment for Pancreatic Cancer As an Alternative to IMRT

    SciTech Connect

    Sebestyen, Zsolt; Kovacs, Peter; Gulyban, Akos; Farkas, Robert; Bellyei, Szabolcs; Liposits, Gabor; Szigeti, Andras; Esik, Olga; Derczy, Katalin; Mangel, Laszlo

    2011-04-01

    When treating pancreatic cancer using standard (ST) 3D conformal radiotherapy (3D-CRT) beam arrangements, the kidneys often receive a higher dose than their probable tolerance limit. Our aim was to elaborate a new planning method that-similarly to IMRT-effectively spares the kidneys without compromising the target coverage. Conformal kidneys sparing (CONKISS) 5-field, noncoplanar plans were compared with ST plans for 23 consecutive patients retrospectively. Optimal beam arrangements were used consisting of a left- and right-wedged beam-pair and an anteroposterior beam inclined in the caudal direction. The wedge direction determination (WEDDE) algorithm was developed to adjust the adequate direction of wedges. The aimed organs at risk (OARs) mean dose limits were: kidney <12 Gy, liver <25 Gy, small bowels <30 Gy, and spinal cord maximum <45 Gy. Conformity and homogeneity indexes with z-test were used to evaluate and compare the different planning approaches. The mean dose to the kidneys decreased significantly (p < 0.05): left kidney 7.7 vs. 10.7 Gy, right kidney 9.1 vs. 11.7 Gy. Meanwhile the mean dose to the liver increased significantly (18.1 vs. 15.0 Gy). The changes in the conformity, homogeneity, and in the doses to other OARs were not significant. The CONKISS method balances the load among the OARs and significantly reduces the dose to the kidneys, without any significant change in the conformity and homogeneity. Using 3D-CRT the CONKISS method can be a smart alternative to IMRT to enhance the possibility of dose escalation.

  9. High-dose radiotherapy in inoperable nonsmall cell lung cancer: comparison of volumetric modulated arc therapy, dynamic IMRT and 3D conformal radiotherapy.

    PubMed

    Bree, Ingrid de; van Hinsberg, Mariëlle G E; van Veelen, Lieneke R

    2012-01-01

    Conformal 3D radiotherapy (3D-CRT) combined with chemotherapy for inoperable non-small cell lung cancer (NSCLC) to the preferable high dose is often not achievable because of dose-limiting organs. This reduces the probability of regional tumor control. Therefore, the surplus value of using intensity-modulated radiation therapy (IMRT) techniques, specifically volumetric modulated arc therapy (RapidArc [RA]) and dynamic IMRT (d-IMRT) has been investigated. RA and d-IMRT plans were compared with 3D-CRT treatment plans for 20 patients eligible for concurrent high-dose chemoradiotherapy, in whom a dose of 60 Gy was not achievable. Comparison of dose delivery in the target volume and organs at risk was carried out by evaluating 3D dose distributions and dose-volume histograms. Quality of the dose distribution was assessed using the inhomogeneity and conformity index. For most patients, a higher dose to the target volume can be delivered using RA or d-IMRT; in 15% of the patients a dose ≥60 Gy was possible. Both IMRT techniques result in a better conformity of the dose (p < 0.001). There are no significant differences in homogeneity of dose in the target volume. IMRT techniques for NSCLC patients allow higher dose to the target volume, thus improving regional tumor control. PMID:22459649

  10. High-dose-rate Three-dimensional Conformal Radiotherapy Combined with Active Breathing Control for Stereotactic Body Radiotherapy of Early-stage Non-small-cell Lung Cancer.

    PubMed

    Wang, Ruozheng; Yin, Yong; Qin, Yonghui; Yu, Jinming

    2015-12-01

    The purpose of this study was to evaluate the feasibility and benefits of using high-dose-rate three-dimensional conformal radiotherapy (3D-CRT) combined with active breathing control (ABC) for stereotactic body radiotherapy (SBRT) of patients with early-stage non-small-cell lung cancer (NSCLC). Eight patients with early-stage NSCLC underwent CT scans under standard free-breathing (FB) and moderately deep inspiration breath-hold (mDIBH) with ABC. Two high-dose-rate 3D-CRT plans (1000 Mu/min) were designed based on the CT scans with FB and mDIBH. The maximal dose (D1%), minimal dose (D99%), conformity index (CI), and homogeneity index (HI) of the planning target volume (PTV), and dose-volume indices of the organs at risk between each plan were compared. The mean PTV volume decreased from 158.04 cm(3) with FB to 76.90 cm(3) with mDIBH (p < 0.05). When mDIBH was used, increases in the affected lung volume (by 47%), contralateral lung volume (by 55%), and total lung volume (by 50%) were observed compared to FB (p < 0.05). The V5-V40 of the affected lung (Vx represented the percentage volume of organs receiving at least the x Gy), V5-V40 and the mean dose for the total lung, V5-V40 and mean dose of the chest wall, and the maximum dose of the spinal cord were less for mDIBH than FB (p < 0.05). There were no significant differences in CI, HI, D1%, or D99% for the PTV between the plans. In conclusion, high-dose-rate 3D-CRT combined with ABC reduced the radiation dose to the lungs and chest wall without affecting the dose distribution in SBRT of early-stage NSCLC patients. PMID:24988055

  11. A Comparison of Gastrointestinal Toxicities between Intensity-Modulated Radiotherapy and Three-Dimensional Conformal Radiotherapy for Pancreatic Cancer

    PubMed Central

    Lee, Kyong Joo; Yoon, Hong In; Chung, Moon Jae; Park, Jeong Youp; Bang, Seungmin; Park, Seung-woo; Seong, Jin Sil; Song, Si Young

    2016-01-01

    Background/Aims Concurrent chemoradiotherapy (CCRT) is considered the treatment option for locally advanced pancreatic cancer, but accompanying gastrointestinal toxicities are the most common complication. With the introduction of three-dimensional conformal radiotherapy (3-D CRT) and intensity-modulated radiotherapy (IMRT), CCRT-related adverse events are expected to diminish. Here, we evaluated the benefits of radiation modalities by comparing gastrointestinal toxicities between 3-D CRT and IMRT. Methods Patients who received CCRT between July 2010 and June 2012 in Severance Hospital, Yonsei University College of Medicine, were enrolled prospectively. The patients underwent upper endoscopy before and 1 month after CCRT. Results A total of 84 patients were enrolled during the study period. The radiotherapy modalities delivered included 3D-CRT (n=40) and IMRT (n=44). The median follow-up period from the start of CCRT was 10.6 months (range, 3.8 to 29.9 months). The symptoms of dyspepsia, nausea/vomiting, and diarrhea did not differ between the groups. Upper endoscopy revealed significantly more gastroduodenal ulcers in the 3-D CRT group (p=0.003). The modality of radiotherapy (3D-CRT; odds ratio [OR], 11.67; p=0.011) and tumor location (body of pancreas; OR, 11.06; p=0.009) were risk factors for gastrointestinal toxicities. Conclusions IMRT is associated with significantly fewer gastroduodenal injuries among patients treated with CCRT for pancreatic cancer. PMID:26470767

  12. Evaluating changes in tumor volume using magnetic resonance imaging during the course of radiotherapy treatment of high-grade gliomas: Implications for conformal dose-escalation studies

    SciTech Connect

    Tsien, Christina . E-mail: ctsien@umich.edu; Gomez-Hassan, Diana; Haken, Randall K. ten; Tatro, Daniel C.; Junck, L.; Chenevert, T.L.; Lawrence, T.

    2005-06-01

    Objective: To determine whether changes in tumor volume occur during the course of conformal 3D radiotherapy of high-grade gliomas by use of magnetic resonance imaging (MRI) during treatment and whether these changes had an impact on tumor coverage. Methods and Materials: Between December 2000 and January 2004, 21 patients with WHO Grades 3 to 4 supratentorial malignant gliomas treated with 3D conformal radiotherapy (median dose, 70 Gy) were enrolled in a prospective clinical study. All patients underwent T1-weighted contrast-enhancing and T2-weighted and fluid-attenuated inversion recovery (FLAIR) imaging at approximately 1 to 2 weeks before radiotherapy, during radiotherapy (Weeks 1 and 3), and at routine intervals thereafter. All MRI scans were coregistered to the treatment-planning CT. Gross tumor volume (GTV Pre-Rx) was defined from a postoperative T1-weighted contrast-enhancing MRI performed 1 to 2 weeks before start of radiotherapy. A second GTV (GTV Week 3) was defined by use of an MRI performed during Week 3 of radiotherapy. A uniform 0.5 cm expansion of the respective GTV, PTV (Pre-Rx), and PTV (Week 3) was applied to the final boost plan. Dose-volume histograms (DVH) were used to analyze any potential adverse changes in tumor coverage based on Week 3 MRI. Results: All MRI scans were reviewed independently by a neuroradiologist (DGH). Two patients were noted to have multifocal disease at presentation and were excluded from analysis. In 19 cases, changes in the GTV based on MRI at Week 3 during radiotherapy were as follows: 2 cases had an objective decrease in GTV ({>=}50%); 12 cases revealed a slight decrease in the rim enhancement or changes in cystic appearance of the GTV; 2 cases showed no change in GTV; and 3 cases demonstrated an increase in tumor volume. Both cases with objective decreases in GTV during treatment were Grade 3 tumors. No cases of tumor progression were noted in Grade 3 tumors during treatment. In comparison, three of 12 Grade 4

  13. Inverse 4D conformal planning for lung SBRT using particle swarm optimization.

    PubMed

    Modiri, A; Gu, X; Hagan, A; Bland, R; Iyengar, P; Timmerman, R; Sawant, A

    2016-08-21

    A critical aspect of highly potent regimens such as lung stereotactic body radiation therapy (SBRT) is to avoid collateral toxicity while achieving planning target volume (PTV) coverage. In this work, we describe four dimensional conformal radiotherapy using a highly parallelizable swarm intelligence-based stochastic optimization technique. Conventional lung CRT-SBRT uses a 4DCT to create an internal target volume and then, using forward-planning, generates a 3D conformal plan. In contrast, we investigate an inverse-planning strategy that uses 4DCT data to create a 4D conformal plan, which is optimized across the three spatial dimensions (3D) as well as time, as represented by the respiratory phase. The key idea is to use respiratory motion as an additional degree of freedom. We iteratively adjust fluence weights for all beam apertures across all respiratory phases considering OAR sparing, PTV coverage and delivery efficiency. To demonstrate proof-of-concept, five non-small-cell lung cancer SBRT patients were retrospectively studied. The 4D optimized plans achieved PTV coverage comparable to the corresponding clinically delivered plans while showing significantly superior OAR sparing ranging from 26% to 83% for D max heart, 10%-41% for D max esophagus, 31%-68% for D max spinal cord and 7%-32% for V 13 lung. PMID:27476472

  14. Inverse 4D conformal planning for lung SBRT using particle swarm optimization

    NASA Astrophysics Data System (ADS)

    Modiri, A.; Gu, X.; Hagan, A.; Bland, R.; Iyengar, P.; Timmerman, R.; Sawant, A.

    2016-08-01

    A critical aspect of highly potent regimens such as lung stereotactic body radiation therapy (SBRT) is to avoid collateral toxicity while achieving planning target volume (PTV) coverage. In this work, we describe four dimensional conformal radiotherapy using a highly parallelizable swarm intelligence-based stochastic optimization technique. Conventional lung CRT-SBRT uses a 4DCT to create an internal target volume and then, using forward-planning, generates a 3D conformal plan. In contrast, we investigate an inverse-planning strategy that uses 4DCT data to create a 4D conformal plan, which is optimized across the three spatial dimensions (3D) as well as time, as represented by the respiratory phase. The key idea is to use respiratory motion as an additional degree of freedom. We iteratively adjust fluence weights for all beam apertures across all respiratory phases considering OAR sparing, PTV coverage and delivery efficiency. To demonstrate proof-of-concept, five non-small-cell lung cancer SBRT patients were retrospectively studied. The 4D optimized plans achieved PTV coverage comparable to the corresponding clinically delivered plans while showing significantly superior OAR sparing ranging from 26% to 83% for D max heart, 10%–41% for D max esophagus, 31%–68% for D max spinal cord and 7%–32% for V 13 lung.

  15. Single-arc volumetric-modulated arc therapy (sVMAT) as adjuvant treatment for gastric cancer: Dosimetric comparisons with three-dimensional conformal radiotherapy (3D-CRT) and intensity-modulated radiotherapy (IMRT)

    SciTech Connect

    Wang, Xin; Li, Guangjun; Zhang, Yingjie; Bai, Sen; Xu, Feng; Wei, Yuquan; Gong, Youling

    2013-01-01

    To compare the dosimetric differences between the single-arc volumetric-modulated arc therapy (sVMAT), 3-dimensional conformal radiotherapy (3D-CRT), and intensity-modulated radiotherapy (IMRT) techniques in treatment planning for gastric cancer as adjuvant radiotherapy. Twelve patients were retrospectively analyzed. In each patient's case, the parameters were compared based on the dose-volume histogram (DVH) of the sVMAT, 3D-CRT, and IMRT plans, respectively. Three techniques showed similar target dose coverage. The maximum and mean doses of the target were significantly higher in the sVMAT plans than that in 3D-CRT plans and in the 3D-CRT/IMRT plans, respectively, but these differences were clinically acceptable. The IMRT and sVMAT plans successfully achieved better target dose conformity, reduced the V{sub 20/30}, and mean dose of the left kidney, as well as the V{sub 20/30} of the liver, compared with the 3D-CRT plans. And the sVMAT technique reduced the V{sub 20} of the liver much significantly. Although the maximum dose of the spinal cord were much higher in the IMRT and sVMAT plans, respectively (mean 36.4 vs 39.5 and 40.6 Gy), these data were still under the constraints. Not much difference was found in the analysis of the parameters of the right kidney, intestine, and heart. The IMRT and sVMAT plans achieved similar dose distribution to the target, but superior to the 3D-CRT plans, in adjuvant radiotherapy for gastric cancer. The sVMAT technique improved the dose sparings of the left kidney and liver, compared with the 3D-CRT technique, but showed few dosimetric advantages over the IMRT technique. Studies are warranted to evaluate the clinical benefits of the VMAT treatment for patients with gastric cancer after surgery in the future.

  16. Factors Influencing Neurocognitive Outcomes in Young Patients With Benign and Low-Grade Brain Tumors Treated With Stereotactic Conformal Radiotherapy

    SciTech Connect

    Jalali, Rakesh; Mallick, Indranil; Dutta, Debnarayan

    2010-07-15

    Purpose: To present the effect of radiotherapy doses to different volumes of normal structures on neurocognitive outcomes in young patients with benign and low-grade brain tumors treated prospectively with stereotactic conformal radiotherapy (SCRT). Methods and Materials: Twenty-eight patients (median age, 13 years) with residual/progressive brain tumors (10 craniopharyngioma, 8 cerebellar astrocytoma, 6 optic pathway glioma and 4 cerebral low-grade glioma) were treated with SCRT to a dose of 54 Gy in 30 fractions over 6 weeks. Prospective neuropsychological assessments were done at baseline before RT and at subsequent follow-up examinations. The change in intelligence quotient (IQ) scores was correlated with various factors, including dose-volume to normal structures. Results: Although the overall mean full-scale IQ (FSIQ) at baseline before RT remained unchanged at 2-year follow-up after SCRT, one third of patients did show a >10% decline in FSIQ as compared with baseline. Logistic regression analysis demonstrated that patients aged <15 years had a significantly higher chance of developing a >10% drop in FSIQ than older patients (53% vs. 10%, p = 0.03). Dosimetric comparison in patients showing a >10% decline vs. patients showing a <10% decline in IQ revealed that patients receiving >43.2 Gy to >13% of volume of the left temporal lobe were the ones to show a significant drop in FSIQ (p = 0.048). Radiotherapy doses to other normal structures, including supratentorial brain, right temporal lobe, and frontal lobes, did not reveal any significant correlation. Conclusion: Our prospectively collected dosimetric data show younger age and radiotherapy doses to left temporal lobe to be predictors of neurocognitive decline, and may well be used as possible dose constraints for high-precision radiotherapy planning.

  17. Normal tissue dose conformality measures to guide radiotherapy fractionation decisions

    SciTech Connect

    Myerson, Robert J.

    2011-04-15

    Purpose: To determine conditions under which hypofractionation could be favorable for a normal tissue--even if tumor [{alpha}/{beta}] exceeds the normal tissue's [{alpha}/{beta}]. Methods: The hypofractionation sufficiency condition (HSC) for an organ is defined as a dose conformality constraint such that, if satisfied, a family of tumor control probability isoeffective fractionation schemes will show decreasing normal tissue complication probability with decreasing number of fractions. Results: In the extended equivalent uniform dose (EUD) model [obtained by replacing dose with linear quadratic (LQ) 2 Gy equivalent dose], the HSC for a normal organ is proven to be satisfied if a suitably weighted average of the relative dose [hypofractionation sufficiency index (HSI)] is less than the ratio of normal tissue to tumor [{alpha}/{beta}]. The HSI is determined solely by dose distribution and the normal tissue volume factor, ''a.'' If the HSC is satisfied for every normal tissue of concern, then there is a therapeutic gain with hypofractionation. The corresponding multifractionation sufficiency condition (therapeutic gain with increasing number of fractions) and multifractionation sufficiency index (MSI) are also derived. A sample clinical case is presented. Conclusions: Within the context of the LQ/EUD models, conformality measures (HSI and MSI) can be used to inform fractionation decisions.

  18. Segmentation of IMRT plans for radical lung radiotherapy delivery with the step-and-shoot technique.

    PubMed

    Nioutsikou, Elena; Bedford, James L; Christian, Judith A; Brada, Michael; Webb, Steve

    2004-04-01

    The purpose of this work was to determine a segmentation protocol for the treatment of localized non-small-cell lung cancer (NSCLC) with intensity-modulated radiotherapy (IMRT) that is as effective as possible while practically simple and hence robust to known practical inaccuracies. This study focused on the stratification of continuous profiles into a discrete number of intensity levels. The selection of the segmentation parameters for the delivery of the fluence profiles using multiple static fields has been considered. Five-field equispaced IMRT treatment plans of five patients with NSCLC were selected. The study comprised nine treatment plans for each patient, starting from a conformal plan, optimizing it for IMRT and then segmenting it utilizing different numbers of segments in each case and optimizing for segment weights separately. A conformal plan, optimized for beam directions, collimator and wedge angles, was also used for comparison with the IMRT plans, so as to consider the best coplanar conformal case. A dose objective for the PTV and the organs-at-risk plus a constraint for the spinal cord were set for all inverse plans. All stages were compared with the aid of dose-volume histograms, dose distributions at the plane of the isocenter, intensity maps for key beams and plots of PTV homogeneity and overall conformality versus complexity. The unsegmented IMRT plans gave the best results but cannot be realized in practice with an MLC. They were best approximated by plans that needed 106-167 segments to deliver, but did not deteriorate significantly when approximated by plans which required 26-40 segments in total. All segmented IMRT plans gave a better lung sparing than the conformal plans, indicating that the deterioration of IMRT plans following segmentation is not equivalent to that of unmodulated, conformal plans. However, optimized conformal plans have the potential to approach the lung sparing achieved by segmented IMRT plans. Among the IMRT

  19. Development and Evaluation of Multiple Isocentric Volumetric Modulated Arc Therapy Technique for Craniospinal Axis Radiotherapy Planning

    SciTech Connect

    Lee, Young K.; Brooks, Corrinne J.; Bedford, James L.; Warrington, Alan P.; Saran, Frank H.

    2012-02-01

    Purpose: To develop and compare a volumetric modulated arc therapy (VMAT) technique with conventional radiotherapy for craniospinal irradiation with respect to improved dose conformity and homogeneity in the planning target volume (PTV) and to reduced dose to organs at risk (OAR). Methods and Materials: Conventional craniospinal axis radiotherapy plans of 5 patients were acquired. The median (range) length of the PTV was 58.9 (48.1-83.7) cm. The 6-MV VMAT plans were inversely planned with one isocenter near the base of the brain and the minimum number of isocenters required for the specified lengths of spine. The plans were optimized with high weighting for PTV coverage and low weighting for OAR sparing. Conformity and heterogeneity indices, dose-volume histograms, mean doses, and non-PTV integral doses from the two plans (prescription dose 23.4 Gy in 13 fractions) were compared. Results: The median (range) conformity index of VMAT was 1.22 (1.09-1.45), compared with 1.69 (1.44-2.67) for conventional plans (p = 0.04). The median (range) heterogeneity index was also lower for VMAT compared with conventional plans: 1.04 (1.03-1.07) vs. 1.12 (1.09-1.19), respectively (p = 0.04). A significant reduction of mean and maximum doses was observed in the heart, thyroid, esophagus, optic nerves, and eyes with VMAT when compared with conventional plans. A decrease in body V{sub 10Gy} was observed, but for 4 of 5 patients non-PTV integral dose was increased with VMAT when compared with the conventional plans. Conclusions: A VMAT technique to treat the craniospinal axis significantly reduces OAR dose, potentially leading to lower late organ toxicity. However, this is achieved at the expense of increased low-dose volumes, which is inherent to the technique, carrying a potentially increased risk of secondary malignancies.

  20. Feasibility of penumbra compensating filters for conformal prostate radiotherapy

    NASA Astrophysics Data System (ADS)

    Cadman, P.; Sidhu, N. P. S.

    2000-02-01

    Radiation therapy beams demonstrate a gradual dose fall-off at the field edges, due to factors affecting the physical penumbra and transport of radiation. Adequate target coverage requires an increase in field size larger than the target volume itself for a uniform dose to be delivered to that target volume. A method is presented for the design and fabrication of penumbra compensating filters (PCFs) which essentially sharpen the penumbra on a field-by-field basis and are used in conjunction with custom shielding blocks. We have explored the feasibility of using PCFs to reduce the field margins required for our four-field conformal prostate treatments. The penumbra compensation is designed based on a profile measured along the direction perpendicular to the blocked field edge that shows the greatest 50% to 95% isodose distance for a typical conformal prostate patient. Rigid foam material is milled and filled with a low melting point alloy material to create a filter which provides dose compensation in the field periphery of the custom shielding block. The accuracy of our methodology has been established using film dosimetry. By employing PCFs, the reduction in the rectal margin ranges from approximately 4 mm in the posterior region to 13 mm in the superior-posterior region, as compared with the shielding blocks alone. The reduction in bladder margin ranges from approximately 4 mm in the superior-anterior region to 10 mm in the superior region. Dose-volume histograms for an idealized cylindrical rectum indicate a substantial reduction in the volume treated to high doses. The calculated normal tissue complication probability values were 8.7% and 10.5% with and without PCFs included in the blocked fields respectively. The advantages of using PCFs, compared with multileaf collimator based techniques, are discussed.

  1. Radiotherapy cost-calculation and its impact on capacity planning.

    PubMed

    Lievens, Yolande; Slotman, Berend Jan

    2003-08-01

    The rapid rise in health care expenses has resulted in an increased interest in the cost of treatments from a cost-effectiveness point of view for management purposes and in a reimbursement setting. The economics of radiotherapy within the global context of health care, and more specifically of cancer therapy, are discussed in this review. Furthermore, the calculation of radiotherapy costs from an institutional perspective using activity-based costing and on capacity planning in radiotherapy - at the departmental as well as at the national level - by integrating cost, epidemiological and scientifico-technological data are focused on. PMID:19807460

  2. Dose verification in carcinoma of uterine cervix patients undergoing 3D conformal radiotherapy with Farmer type ion chamber

    PubMed Central

    Srinivas, Challapalli; Kumar, P Suman; Ravichandran, Ramamoorthy; Banerjee, S; Saxena, P.U; Kumar, E.S Arun; Pai, Dinesh K.

    2014-01-01

    External beam radiotherapy (EBRT) for carcinoma of uterine cervix is a basic line of treatment with three dimensional conformal radiotherapy (3DCRT) in large number of patients. There is need for an established method for verification dosimetry. We tried to document absorbed doses in a group of carcinoma cervix patients by inserting a 0.6 cc Farmer type ion chamber in the vaginal cavity. A special long perspex sleeve cap is designed to cover the chamber for using in the patient's body. Response of ionization chamber is checked earlier in water phantom with and without cap. Treatment planning was carried out with X-ray computed tomography (CT) scan and with the chamber along with cap in inserted position, and with the images Xio treatment planning system. Three measurements on 3 days at 5-6 fraction intervals were recorded in 12 patients. Electrometer measured charges are converted to absorbed dose at the chamber center, in vivo. Our results show good agreement with planned dose within 3% against prescribed dose. This study, is a refinement over our previous studies with transmission dosimetry and chemicals in ampules. This preliminary work shows promise that this can be followed as a routine dose check with special relevance to new protocols in the treatment of carcinoma cervix with EBRT. PMID:25525313

  3. Treatment planning for radiotherapy with very high-energy electron beams and comparison of VHEE and VMAT plans

    SciTech Connect

    Bazalova-Carter, Magdalena; Qu, Bradley; Palma, Bianey; Jensen, Christopher; Maxim, Peter G. E-mail: BWLoo@Stanford.edu; Loo, Billy W. E-mail: BWLoo@Stanford.edu; Hårdemark, Björn; Hynning, Elin

    2015-05-15

    plan, OAR doses were up to 70% lower and the integral dose was 33% lower for VHEE compared to 6 MV VMAT. Additionally, VHEE conformity indices (CI{sub 100} = 1.09 and CI{sub 50} = 4.07) were better than VMAT conformity indices (CI{sub 100} = 1.30 and CI{sub 50} = 6.81). The 100 MeV VHEE lung plan resulted in mean dose decrease to all OARs by up to 27% for the same target coverage compared to the clinical 6 MV flattening filter-free (FFF) VMAT plan. The 100 MeV prostate plan resulted in 3% mean dose increase to the penile bulb and the urethra, but all other OAR mean doses were lower compared to the 15 MV VMAT plan. The lung case CI{sub 100} and CI{sub 50} conformity indices were 3% and 8% lower, respectively, in the VHEE plan compared to the VMAT plan. The prostate case CI{sub 100} and CI{sub 50} conformity indices were 1% higher and 8% lower, respectively, in the VHEE plan compared to the VMAT plan. Conclusions: The authors have developed a treatment planning workflow for MC dose calculation of pencil beams and optimization for treatment planning of VHEE radiotherapy. The authors have demonstrated that VHEE plans resulted in similar or superior dose distributions for pediatric, lung, and prostate cases compared to clinical VMAT plans.

  4. Intensity modulated radiotherapy in early stage Hodgkin lymphoma patients: Is it better than three dimensional conformal radiotherapy?

    PubMed Central

    2012-01-01

    Background Cure rate of early Hodgkin Lymphoma are high and avoidance of late toxicities is of paramount importance. This comparative study aims to assess the normal tissue sparing capability of intensity-modulated radiation therapy (IMRT) versus standard three-dimensional conformal radiotherapy (3D-CRT) in terms of dose-volume parameters and normal tissue complication probability (NTCP) for different organs at risk in supradiaphragmatic Hodgkin Lymphoma (HL) patients. Methods Ten HL patients were actually treated with 3D-CRT and all treatments were then re-planned with IMRT. Dose-volume parameters for thyroid, oesophagus, heart, coronary arteries, lung, spinal cord and breast were evaluated. Dose-volume histograms generated by TPS were analyzed to predict the NTCP for the considered organs at risk, according to different endpoints. Results Regarding dose-volume parameters no statistically significant differences were recorded for heart and origin of coronary arteries. We recorded statistically significant lower V30 with IMRT for oesophagus (6.42 vs 0.33, p = 0.02) and lungs (4.7 vs 0.1 p = 0.014 for the left lung and 2.59 vs 0.1 p = 0.017 for the right lung) and lower V20 for spinal cord (17.8 vs 7.2 p = 0.02). Moreover the maximum dose to the spinal cord was lower with IMRT (30.2 vs 19.9, p <0.001). Higher V10 with IMRT for thyroid (64.8 vs 95, p = 0.0019) and V5 for lungs (30.3 vs 44.8, p = 0.03, for right lung and 28.9 vs 48.1, p = 0.001 for left lung) were found, respectively. Higher V5 and V10 for breasts were found with IMRT (V5: 4.14 vs 20.6, p = 0.018 for left breast and 3.3 vs 17, p = 0.059 for right breast; V10: 2.5 vs 13.6 p = 0.035 for left breast and 1.7 vs 11, p = 0.07 for the right breast.) As for the NTCP, our data point out that IMRT is not always likely to significantly increase the NTCP to OARs. Conclusions In HL male patients IMRT seems feasible and accurate while for women HL patients IMRT should be

  5. Estimating the costs of intensity-modulated and 3-dimensional conformal radiotherapy in Ontario

    PubMed Central

    Yong, J.H.E.; McGowan, T.; Redmond-Misner, R.; Beca, J.; Warde, P.; Gutierrez, E.; Hoch, J.S.

    2016-01-01

    Background Radiotherapy is a common treatment for many cancers, but up-to-date estimates of the costs of radiotherapy are lacking. In the present study, we estimated the unit costs of intensity-modulated radiotherapy (imrt) and 3-dimensional conformal radiotherapy (3D-crt) in Ontario. Methods An activity-based costing model was developed to estimate the costs of imrt and 3D-crt in prostate cancer. It included the costs of equipment, staff, and supporting infrastructure. The framework was subsequently adapted to estimate the costs of radiotherapy in breast cancer and head-and-neck cancer. We also tested various scenarios by varying the program maturity and the use of volumetric modulated arc therapy (vmat) alongside imrt. Results From the perspective of the health care system, treating prostate cancer with imrt and 3D-crt respectively cost $12,834 and $12,453 per patient. The cost of radiotherapy ranged from $5,270 to $14,155 and was sensitive to analytic perspective, radiation technique, and disease site. Cases of head-and-neck cancer were the most costly, being driven by treatment complexity and fractions per treatment. Although imrt was more costly than 3D-crt, its cost will likely decline over time as programs mature and vmat is incorporated. Conclusions Our costing model can be modified to estimate the costs of 3D-crt and imrt for various disease sites and settings. The results demonstrate the important role of capital costs in studies of radiotherapy cost from a health system perspective, which our model can accommodate. In addition, our study established the need for future analyses of imrt cost to consider how vmat affects time consumption. PMID:27330359

  6. Phase I study of conformal radiotherapy with concurrent gemcitabine in locally advanced bladder cancer

    SciTech Connect

    Sangar, Vijay K.; McBain, Catherine A.; Lyons, Jeanette; Ramani, Vijay; Logue, John; Wylie, James; Clarke, Noel W.; Cowan, Richard A. . E-mail: richard.cowan@christie-tr.nwest.nhs.uk

    2005-02-01

    Purpose: A prospective phase I trial was conducted to determine the maximal tolerated dose of gemcitabine given once weekly during hypofractionated conformal radiotherapy to patients with locally advanced transitional cell carcinoma of the bladder. Eight male patients, median age 69 years, with Stage T2 (n = 4) or T3 (n = 4) N0M0, were enrolled in cohorts of 3. Treatment comprised conformal radiotherapy (52.5 Gy in 20 fractions) within 4 weeks, with concurrent gemcitabine once weekly for four cycles. The weekly gemcitabine dose was escalated from 100 mg/m{sup 2} in increments of 50 mg/m{sup 2} per cohort. Dose-limiting toxicity was defined as any acute Radiation Therapy Oncology Group (RTOG) toxicity Grade 3 or greater arising in >1 of 3 patients in each cohort. Tumor response was assessed cystoscopically and radiologically at 3 months. Results: All 8 patients completed radiotherapy, and 6 of 8 completed chemoradiotherapy. No acute toxicity greater than RTOG Grade 1 was seen with gemcitabine at 100 mg/m{sup 2}. Dose-limiting toxicity was observed at 150 mg/m{sup 2} with Grade 3 toxicity seen in 2 of 2 patients (one bladder, one bowel). An additional 3 patients received 100 mg/m{sup 2} with minimal toxicity. No hematologic toxicity was encountered. A complete response was seen in 7 (87.5%) of 8 patients, all of whom were disease free at a median follow-up of 19.5 months (range, 14-23 months). No late toxicity (greater than RTOG Grade 0) has been observed. Conclusion: The maximal tolerated dose for gemcitabine given once weekly with concurrent hypofractionated conformal bladder radiotherapy was 150 mg/m{sup 2}, with a maximal recommended dose of 100 mg/m{sup 2}. This dose regimen has now entered Phase II clinical trials.

  7. Dosimetric Comparison of Three-Dimensional Conformal Proton Radiotherapy, Intensity-Modulated Proton Therapy, and Intensity-Modulated Radiotherapy for Treatment of Pediatric Craniopharyngiomas

    SciTech Connect

    Boehling, Nicholas S.; Grosshans, David R.; Bluett, Jaques B.; Palmer, Matthew T.; Song, Xiaofei; Amos, Richard A.; Sahoo, Narayan; Meyer, Jeffrey J.; Mahajan, Anita; Woo, Shiao Y.

    2012-02-01

    Purpose: Cranial irradiation in pediatric patients is associated with serious long-term adverse effects. We sought to determine whether both three-dimensional conformal proton radiotherapy (3D-PRT) and intensity-modulated proton therapy (IMPT) compared with intensity-modulated radiotherapy (IMRT) decrease integral dose to brain areas known to harbor neuronal stem cells, major blood vessels, and other normal brain structures for pediatric patients with craniopharyngiomas. Methods and Materials: IMRT, forward planned, passive scattering proton, and IMPT plans were generated and optimized for 10 pediatric patients. The dose was 50.4 Gy (or cobalt Gy equivalent) delivered in 28 fractions with the requirement for planning target volume (PTV) coverage of 95% or better. Integral dose data were calculated from differential dose-volume histograms. Results: The PTV target coverage was adequate for all modalities. IMRT and IMPT yielded the most conformal plans in comparison to 3D-PRT. Compared with IMRT, 3D-PRT and IMPT plans had a relative reduction of integral dose to the hippocampus (3D-PRT, 20.4; IMPT, 51.3%{sup Asterisk-Operator }), dentate gyrus (27.3, 75.0%{sup Asterisk-Operator }), and subventricular zone (4.5, 57.8%{sup Asterisk-Operator }). Vascular organs at risk also had reduced integral dose with the use of proton therapy (anterior cerebral arteries, 33.3{sup Asterisk-Operator }, 100.0%{sup Asterisk-Operator }; middle cerebral arteries, 25.9%{sup Asterisk-Operator }, 100%{sup Asterisk-Operator }; anterior communicating arteries, 30.8{sup Asterisk-Operator }, 41.7%{sup Asterisk-Operator }; and carotid arteries, 51.5{sup Asterisk-Operator }, 77.6{sup Asterisk-Operator }). Relative reduction of integral dose to the infratentorial brain (190.7{sup Asterisk-Operator }, 109.7%{sup Asterisk-Operator }), supratentorial brain without PTV (9.6, 26.8%{sup Asterisk-Operator }), brainstem (45.6, 22.4%{sup Asterisk-Operator }), and whole brain without PTV (19.4{sup Asterisk

  8. Development of a MicroCT-Based Image-Guided Conformal Radiotherapy System for Small Animals

    PubMed Central

    Zhou, Hu; Rodriguez, Manuel; van den Haak, Fred; Nelson, Geoffrey; Jogani, Rahil; Xu, Jiali; Zhu, Xinzhi; Xian, Yongjiang; Tran, Phuoc T.; Felsher, Dean W.; Keall, Paul J.; Graves, Edward E.

    2009-01-01

    Purpose The need for clinically-relevant radiation therapy technology for the treatment of preclinical models of disease has spurred the development of a variety of dedicated platforms for small animal irradiation. Our group has taken the approach of adding the ability to deliver conformal radiotherapy to an existing 120 kVp micro-computed tomography (microCT) scanner. Methods A GE eXplore RS120 microCT scanner was modified by the addition of a two-dimensional subject translation stage and a variable aperture collimator. Quality assurance protocols for these devices, including measurement of translation stage positioning accuracy, collimator aperture accuracy, and collimator alignment with the x-ray beam, were devised. Use of this system for image-guided radiotherapy was assessed by irradiation of a solid water phantom as well as of two mice bearing spontaneous MYC-induced lung tumors. Radiation damage was assessed ex vivo by immunohistochemical detection of γH2AX foci. Results The positioning error of the translation stage was found to be less than 0.05 mm, while after alignment of the collimator with the x-ray axis through adjustment of its displacement and rotation, the collimator aperture error was less than 0.1 mm measured at isocenter. CT image-guided treatment of a solid water phantom demonstrated target localization accuracy to within 0.1 mm. γH2AX foci were detected within irradiated lung tumors in mice, with contralateral lung tissue displaying background staining. Conclusions Addition of radiotherapy functionality to a microCT scanner is an effective means of introducing image-guided radiation treatments into the preclinical setting. This approach has been shown to facilitate small animal conformal radiotherapy while leveraging existing technology. PMID:20395069

  9. Radiation planning comparison for superficial tissue avoidance in radiotherapy for soft tissue sarcoma of the lower extremity

    SciTech Connect

    Griffin, Anthony M.; Euler, Colleen I.; Sharpe, Michael B.; Ferguson, Peter C.; Wunder, Jay S.; Bell, Robert S.; Chung, Peter W.M.; Catton, Charles N.; O'Sullivan, Brian . E-mail: brian.osullivan@rmp.uhn.on.ca

    2007-03-01

    Purpose: Three types of preoperative radiotherapy (RT) plans for extremity soft tissue sarcoma were compared to determine the amount of dose reduction possible to the planned surgical skin flaps required for tumor resection and wound closure, without compromising target coverage. Methods and Materials: Twenty-four untreated patients with large, deep, lower extremity STS treated with preoperative RT and limb salvage surgery had their original conventional treatment plans re-created. The same clinical target volume was used for all three plans. The future surgical skin flaps were created virtually through contouring by the treating surgeon and regarded as an organ at risk. The original, conformal, and intensity-modulated RT (IMRT) plans were created to deliver 50 Gy in 25 fractions to the clinical target volume. Clinical target volume and organ-at-risk dose-volume histograms were calculated and the plans compared for conformality, target coverage, and dose sparing. Results: The mean dose to the planned skin flaps was 42.62 Gy (range, 30.24-48.65 Gy) for the original plans compared with 40.12 Gy (range, 24.24-47.26 Gy) for the conformal plans and 26.71 Gy (range, 22.31-31.91 Gy) for the IMRT plans (p = 0.0008). An average of 86.4% (range, 53.2-97.4%) of the planned skin flaps received {>=}30 Gy in the original plans compared with 83.4% (range, 36.2-96.2%) in the conformal plans and only 34.0% (range, 22.5-53.3%) in the IMRT plans (p = 0.0001). IMRT improved target conformality compared with the original and conformal plans (1.27, 2.34, and 1.76, respectively, p = 0.0001). Conclusion: In a retrospective review, preoperative IMRT substantially lowered the dose to the future surgical skin flaps, sparing a greater percentage of this structure's volume without compromising target (tumor) coverage.

  10. Evaluation of flexible and rigid (class solution) radiation therapy conformal prostate planning protocols

    SciTech Connect

    Coburn, Natalie; Beldham-Collins, Rachael; Westling, Jelene; Trovato, Jenny; Gebski, Val

    2012-04-01

    Protocols commonly implemented in radiotherapy work areas may be classified as being either rigid (class solution) or flexible. Because formal evaluation of these protocol types has not occurred within the literature, we evaluated the efficiency of a rigid compared with flexible prostate planning protocol by assessing a series of completed 3D conformal prostate plans. Twenty prostate cancer patients with an average age of 70 years (range, 52-77) and sizes comprising 8 small, 10 medium, and 2 large were planned on the Phillips Pinnacle treatment planning system 6 times by radiation therapists with <2 years, 2-5 years, and >5 years of experience using a rigid and flexible protocol. Plans were critiqued using critical organ doses, confirmation numbers, and conformity index. Plans were then classified as being acceptable or not. Plans produced with the flexible protocol were 53% less likely to require modification (OR 0.47, 95% CI: 0.26, 0.84, p = 0.01). Planners with >5 years of experience were 78% more likely to produce plans requiring modification (OR 1.78, 95% CI: 1.12, 2.83, P = 0.02). Plans according to the flexible protocol took longer (112 min) compared with the time taken using a rigid protocol (68 min) (p < 0.001). The results suggest that further studies are needed; however, we propose that all radiation therapy planners should start with the same limitations, and if an acceptable plan is not reached, then flexibility should be given to improve the plan to meet the desired results.

  11. Dosimetric correlation of acute and late toxicities in high-risk prostate cancer patients treated with three-dimensional conformal radiotherapy followed by intensity modulated radiotherapy boost

    PubMed Central

    Kapoor, Rakesh; Bansal, Anshuma; Kumar, Narendra; Oinam, Arun S.

    2016-01-01

    Introduction: In prostate cancer, higher radiation doses are often related to higher local control rates. However, the clinical effect of these higher doses on normal tissue toxicities is generally overlooked. We dosimetrically analyze sequential intensity modulated radiotherapy (IMRT) plans in high-risk prostate cancer patients and correlate them with acute and late normal tissue toxicities. Materials and Methods: Twenty-five high-risk prostate cancer patients were planned with three-dimensional conformal radiotherapy to a dose of 50 Gy delivered in 25 fractions in 5 weeks, followed by seven-field IMRT boost, to a dose of 24 Gy delivered in 12 fractions in 2.5 weeks, along with hormonal therapy. Acute and late toxicities were analyzed using Radiation Therapy Oncology Group toxicity criteria. Student's t-test was used for correlating doses received by normal tissues with toxicity grade. Five-year disease-free survival (DFS) and biochemical relapse-free survival (RFS) were evaluated using Kaplan–Meier analysis. Results: Median follow-up of patients was 65 months. Of 25 patients, two developed acute Grade 2 rectal toxicity. Only 1 patient developed acute Grade 2 bladder toxicity. Late Grade 2 and 3 rectal toxicity was seen in 2 and 1 patient, respectively. Late Grade 2 and 3 bladder toxicity was seen in 1 patient each. Grade 2 or more acute rectal toxicity correlated significantly with rectal volume receiving >70 Gy (P = 0.04). The 5-year DFS and biochemical RFS was 70.2% and 79.2%, respectively. One patient failed locally and seven failed at distant sites. Conclusion: Sequential IMRT with a dose of 74 Gy and maximum androgen blockade is well tolerated in high-risk patients in Indian setup with adequate control rates. PMID:27555679

  12. Bayesian network models for error detection in radiotherapy plans

    NASA Astrophysics Data System (ADS)

    Kalet, Alan M.; Gennari, John H.; Ford, Eric C.; Phillips, Mark H.

    2015-04-01

    The purpose of this study is to design and develop a probabilistic network for detecting errors in radiotherapy plans for use at the time of initial plan verification. Our group has initiated a multi-pronged approach to reduce these errors. We report on our development of Bayesian models of radiotherapy plans. Bayesian networks consist of joint probability distributions that define the probability of one event, given some set of other known information. Using the networks, we find the probability of obtaining certain radiotherapy parameters, given a set of initial clinical information. A low probability in a propagated network then corresponds to potential errors to be flagged for investigation. To build our networks we first interviewed medical physicists and other domain experts to identify the relevant radiotherapy concepts and their associated interdependencies and to construct a network topology. Next, to populate the network’s conditional probability tables, we used the Hugin Expert software to learn parameter distributions from a subset of de-identified data derived from a radiation oncology based clinical information database system. These data represent 4990 unique prescription cases over a 5 year period. Under test case scenarios with approximately 1.5% introduced error rates, network performance produced areas under the ROC curve of 0.88, 0.98, and 0.89 for the lung, brain and female breast cancer error detection networks, respectively. Comparison of the brain network to human experts performance (AUC of 0.90 ± 0.01) shows the Bayes network model performs better than domain experts under the same test conditions. Our results demonstrate the feasibility and effectiveness of comprehensive probabilistic models as part of decision support systems for improved detection of errors in initial radiotherapy plan verification procedures.

  13. Bayesian network models for error detection in radiotherapy plans.

    PubMed

    Kalet, Alan M; Gennari, John H; Ford, Eric C; Phillips, Mark H

    2015-04-01

    The purpose of this study is to design and develop a probabilistic network for detecting errors in radiotherapy plans for use at the time of initial plan verification. Our group has initiated a multi-pronged approach to reduce these errors. We report on our development of Bayesian models of radiotherapy plans. Bayesian networks consist of joint probability distributions that define the probability of one event, given some set of other known information. Using the networks, we find the probability of obtaining certain radiotherapy parameters, given a set of initial clinical information. A low probability in a propagated network then corresponds to potential errors to be flagged for investigation. To build our networks we first interviewed medical physicists and other domain experts to identify the relevant radiotherapy concepts and their associated interdependencies and to construct a network topology. Next, to populate the network's conditional probability tables, we used the Hugin Expert software to learn parameter distributions from a subset of de-identified data derived from a radiation oncology based clinical information database system. These data represent 4990 unique prescription cases over a 5 year period. Under test case scenarios with approximately 1.5% introduced error rates, network performance produced areas under the ROC curve of 0.88, 0.98, and 0.89 for the lung, brain and female breast cancer error detection networks, respectively. Comparison of the brain network to human experts performance (AUC of 0.90 ± 0.01) shows the Bayes network model performs better than domain experts under the same test conditions. Our results demonstrate the feasibility and effectiveness of comprehensive probabilistic models as part of decision support systems for improved detection of errors in initial radiotherapy plan verification procedures. PMID:25768885

  14. Pancreatic cancer planning: Complex conformal vs modulated therapies.

    PubMed

    Chapman, Katherine L; Witek, Matthew E; Chen, Hongyu; Showalter, Timothy N; Bar-Ad, Voichita; Harrison, Amy S

    2016-01-01

    To compare the roles of intensity-modulated radiation therapy (IMRT) and volumetric- modulated arc therapy (VMAT) therapy as compared to simple and complex 3-dimensional chemoradiotherpy (3DCRT) planning for resectable and borderline resectable pancreatic cancer. In all, 12 patients who received postoperative radiotherapy (8) or neoadjuvant concurrent chemoradiotherapy (4) were evaluated retrospectively. Radiotherapy planning was performed for 4 treatment techniques: simple 4-field box, complex 5-field 3DCRT, 5 to 6-field IMRT, and single-arc VMAT. All volumes were approved by a single observer in accordance with Radiation Therapy Oncology Group (RTOG) Pancreas Contouring Atlas. Plans included tumor/tumor bed and regional lymph nodes to 45Gy; with tumor/tumor bed boosted to 50.4Gy, at least 95% of planning target volume (PTV) received the prescription dose. Dose-volume histograms (DVH) for multiple end points, treatment planning, and delivery time were assessed. Complex 3DCRT, IMRT, and VMAT plans significantly (p < 0.05) decreased mean kidney dose, mean liver dose, liver (V30, V35), stomach (D10%), stomach (V45), mean right kidney dose, and right kidney (V15) as compared with the simple 4-field plans that are most commonly reported in the literature. IMRT plans resulted in decreased mean liver dose, liver (V35), and left kidney (V15, V18, V20). VMAT plans decreased small bowel (D10%, D15%), small bowel (V35, V45), stomach (D10%, D15%), stomach (V35, V45), mean liver dose, liver (V35), left kidney (V15, V18, V20), and right kidney (V18, V20). VMAT plans significantly decreased small bowel (D10%, D15%), left kidney (V20), and stomach (V45) as compared with IMRT plans. Treatment planning and delivery times were most efficient for simple 4-field box and VMAT. Excluding patient setup and imaging, average treatment delivery was within 10minutes for simple and complex 3DCRT, IMRT, and VMAT treatments. This article shows significant improvements in 3D plan performance

  15. Newer positron emission tomography radiopharmaceuticals for radiotherapy planning: an overview

    PubMed Central

    Mukherjee, Anirban

    2016-01-01

    Positron emission tomography-computed tomography (PET-CT) has changed cancer imaging in the last decade, for better. It can be employed for radiation treatment planning of different cancers with improved accuracy and outcomes as compared to conventional imaging methods. 18F-fluorodeoxyglucose remains the most widely used though relatively non-specific cancer imaging PET tracer. A wide array of newer PET radiopharmaceuticals has been developed for targeted imaging of different cancers. PET-CT with such new PET radiopharmaceuticals has also been used for radiotherapy planning with encouraging results. In the present review we have briefly outlined the role of PET-CT with newer radiopharmaceuticals for radiotherapy planning and briefly reviewed the available literature in this regard. PMID:26904575

  16. Conformal Brachytherapy Planning for Cervical Cancer Using Transabdominal Ultrasound

    SciTech Connect

    Van Dyk, Sylvia Narayan, Kailash; Fisher, Richard; Bernshaw, David

    2009-09-01

    Purpose: To determine if transabdominal ultrasound (US) can be used for conformal brachytherapy in cervical cancer patients. Materials and Methods: Seventy-one patients with locoregionally advanced cervix cancer treated with chemoradiation and brachytherapy were included in this study. The protocol consisted of US-assisted tandem insertion and conformal US-based planning. Orthogonal films for applicator reconstruction were also taken. A standard plan was modified to suit the US-based volume and treatment was delivered. The patient then underwent a magnetic resonance imaging (MRI) scan with the applicators in situ. Retrospectively, individual standard (STD), US, and MRI plans were extrapolated for five fractions and superimposed onto the two-dimensional sagittal MRI images for comparison. Doses to Point A, target volume, International Commission on Radiation Units and Measurements (ICRU) 38 bladder and rectal points, and individualized bowel points were calculated on original implant geometry on Plato for each planning method. Results: STD (high-dose-rate) plans reported higher doses to Point A, target volume, ICRU 38 bladder and rectal points, and individualized bowel point compared with US and MRI plans. There was a statistically significant difference between standard plans and image-based plans-STD vs. US, STD vs. MRI, and STD vs. Final-having consistent (p {<=} 0.001) respectively for target volume, Point A, ICRU 38 bladder, and bowel point. US plan assessed on two-dimensional MRI image was comparable for target volume (p = 0.11), rectal point (p = 0.8), and vaginal mucosa (p = 0.19). Local control was 90%. Late bowel morbidity (G3, G4) was <2%. Conclusions: Transabdominal ultrasound offers an accurate, quick, accessible, and cost-effective method of conformal brachytherapy planning.

  17. Mediastinal irradiation in a patient affected by lung carcinoma after heart transplantation: Helical tomotherapy versus three dimensional conformal radiotherapy

    PubMed Central

    Iorio, Vincenzo; Cammarota, Fabrizio; Toledo, Diego; Senese, Rossana; Francomacaro, Ferdinando; Muto, Matteo; Muto, Paolo

    2016-01-01

    Abstract Patients who have undergone solid organ transplants are known to have an increased risk of neoplasia compared with the general population. We report our experience using mediastinal irradiation with helical tomotherapy versus three‐dimensional conformal radiation therapy to treat a patient with lung carcinoma 15 years after heart transplantation. Our dosimetric evaluation showed no particular difference between the techniques, with the exception of some organs. Mediastinal irradiation after heart transplantation is feasible and should be considered after evaluation of the risk. Conformal radiotherapy or intensity‐modulated radiotherapy appears to be the appropriate treatment in heart‐transplanted oncologic patients. PMID:27148425

  18. Mediastinal irradiation in a patient affected by lung carcinoma after heart transplantation: Helical tomotherapy versus three dimensional conformal radiotherapy.

    PubMed

    Giugliano, Francesca M; Iorio, Vincenzo; Cammarota, Fabrizio; Toledo, Diego; Senese, Rossana; Francomacaro, Ferdinando; Muto, Matteo; Muto, Paolo

    2016-04-26

    Patients who have undergone solid organ transplants are known to have an increased risk of neoplasia compared with the general population. We report our experience using mediastinal irradiation with helical tomotherapy versus three-dimensional conformal radiation therapy to treat a patient with lung carcinoma 15 years after heart transplantation. Our dosimetric evaluation showed no particular difference between the techniques, with the exception of some organs. Mediastinal irradiation after heart transplantation is feasible and should be considered after evaluation of the risk. Conformal radiotherapy or intensity-modulated radiotherapy appears to be the appropriate treatment in heart-transplanted oncologic patients. PMID:27148425

  19. Reducing scatter radiation to the contralateral breast with a mobile, conformal shield during breast cancer radiotherapy.

    PubMed

    Macklis, R M; Crownover, R L; Crowe, J; Willoughby, T; Sohn, J

    1999-08-01

    During a standard course of breast radiotherapy, the contralateral breast generally receives approximately 2.5 to 6.0 Gy of scattered radiation. Although most studies have not found an overall increase in metachronous contralateral breast cancers in patients undergoing radiotherapy, a cohort of younger women may be genetically more susceptible to radiation-induced breast cancers and may thus be adversely affected by the scattered radiation. We are attempting to develop a simple, convenient, effective mechanism for minimizing the scattered radiation to the contralateral breast during the process of clinical breast radiotherapy. We therefore designed a conformal, platform-based breast shield consisting of 2.5 cm of molded lead in a mobile counterweighted polystyrene casing. This shield was intended to serve as a physical barrier to prevent both low and high energy scattered photons from the medial and lateral tangential fields. We conducted a prospective trial of 20 women, each woman serving as her own control. Each woman received breast radiotherapy with and without shield, and an array of thermoluminescent dosimeters was positioned across the contralateral breast to evaluate the in vivo dosimetry and the impact of the breast shield on surface absorption of scattered radiation. We found that the use of the breast shield reduced the median dose of scattered radiation by approximately 60% (p < 0.0001). This represented a median dose reduction of approximately 300 cGy at the nipple. The shield was easily positioned and added < 1 min to daily setup time. We conclude that the use of this sort of surface barrier shielding technique was feasible, effective, and practical for clinical use. The degree of scatter reduction accomplished through the use of this breast shield may be biologically significant, especially for those patients with biologic or epidemiologic risk factors that may predispose them to the development of radiogenic breast cancers. PMID:10440204

  20. Approximating convex Pareto surfaces in multiobjective radiotherapy planning

    SciTech Connect

    Craft, David L.; Halabi, Tarek F.; Shih, Helen A.; Bortfeld, Thomas R.

    2006-09-15

    Radiotherapy planning involves inherent tradeoffs: the primary mission, to treat the tumor with a high, uniform dose, is in conflict with normal tissue sparing. We seek to understand these tradeoffs on a case-to-case basis, by computing for each patient a database of Pareto optimal plans. A treatment plan is Pareto optimal if there does not exist another plan which is better in every measurable dimension. The set of all such plans is called the Pareto optimal surface. This article presents an algorithm for computing well distributed points on the (convex) Pareto optimal surface of a multiobjective programming problem. The algorithm is applied to intensity-modulated radiation therapy inverse planning problems, and results of a prostate case and a skull base case are presented, in three and four dimensions, investigating tradeoffs between tumor coverage and critical organ sparing.

  1. Methods and computer readable medium for improved radiotherapy dosimetry planning

    DOEpatents

    Wessol, Daniel E.; Frandsen, Michael W.; Wheeler, Floyd J.; Nigg, David W.

    2005-11-15

    Methods and computer readable media are disclosed for ultimately developing a dosimetry plan for a treatment volume irradiated during radiation therapy with a radiation source concentrated internally within a patient or incident from an external beam. The dosimetry plan is available in near "real-time" because of the novel geometric model construction of the treatment volume which in turn allows for rapid calculations to be performed for simulated movements of particles along particle tracks therethrough. The particles are exemplary representations of alpha, beta or gamma emissions emanating from an internal radiation source during various radiotherapies, such as brachytherapy or targeted radionuclide therapy, or they are exemplary representations of high-energy photons, electrons, protons or other ionizing particles incident on the treatment volume from an external source. In a preferred embodiment, a medical image of a treatment volume irradiated during radiotherapy having a plurality of pixels of information is obtained.

  2. Automatic liver contouring for radiotherapy treatment planning

    NASA Astrophysics Data System (ADS)

    Li, Dengwang; Liu, Li; Kapp, Daniel S.; Xing, Lei

    2015-09-01

    To develop automatic and efficient liver contouring software for planning 3D-CT and four-dimensional computed tomography (4D-CT) for application in clinical radiation therapy treatment planning systems. The algorithm comprises three steps for overcoming the challenge of similar intensities between the liver region and its surrounding tissues. First, the total variation model with the L1 norm (TV-L1), which has the characteristic of multi-scale decomposition and an edge-preserving property, is used for removing the surrounding muscles and tissues. Second, an improved level set model that contains both global and local energy functions is utilized to extract liver contour information sequentially. In the global energy function, the local correlation coefficient (LCC) is constructed based on the gray level co-occurrence matrix both of the initial liver region and the background region. The LCC can calculate the correlation of a pixel with the foreground and background regions, respectively. The LCC is combined with intensity distribution models to classify pixels during the evolutionary process of the level set based method. The obtained liver contour is used as the candidate liver region for the following step. In the third step, voxel-based texture characterization is employed for refining the liver region and obtaining the final liver contours. The proposed method was validated based on the planning CT images of a group of 25 patients undergoing radiation therapy treatment planning. These included ten lung cancer patients with normal appearing livers and ten patients with hepatocellular carcinoma or liver metastases. The method was also tested on abdominal 4D-CT images of a group of five patients with hepatocellular carcinoma or liver metastases. The false positive volume percentage, the false negative volume percentage, and the dice similarity coefficient between liver contours obtained by a developed algorithm and a current standard delineated by the expert group

  3. Automatic liver contouring for radiotherapy treatment planning.

    PubMed

    Li, Dengwang; Liu, Li; Kapp, Daniel S; Xing, Lei

    2015-10-01

    To develop automatic and efficient liver contouring software for planning 3D-CT and four-dimensional computed tomography (4D-CT) for application in clinical radiation therapy treatment planning systems.The algorithm comprises three steps for overcoming the challenge of similar intensities between the liver region and its surrounding tissues. First, the total variation model with the L1 norm (TV-L1), which has the characteristic of multi-scale decomposition and an edge-preserving property, is used for removing the surrounding muscles and tissues. Second, an improved level set model that contains both global and local energy functions is utilized to extract liver contour information sequentially. In the global energy function, the local correlation coefficient (LCC) is constructed based on the gray level co-occurrence matrix both of the initial liver region and the background region. The LCC can calculate the correlation of a pixel with the foreground and background regions, respectively. The LCC is combined with intensity distribution models to classify pixels during the evolutionary process of the level set based method. The obtained liver contour is used as the candidate liver region for the following step. In the third step, voxel-based texture characterization is employed for refining the liver region and obtaining the final liver contours.The proposed method was validated based on the planning CT images of a group of 25 patients undergoing radiation therapy treatment planning. These included ten lung cancer patients with normal appearing livers and ten patients with hepatocellular carcinoma or liver metastases. The method was also tested on abdominal 4D-CT images of a group of five patients with hepatocellular carcinoma or liver metastases. The false positive volume percentage, the false negative volume percentage, and the dice similarity coefficient between liver contours obtained by a developed algorithm and a current standard delineated by the expert group

  4. MRI-based treatment plan simulation and adaptation for ion radiotherapy using a classification-based approach

    PubMed Central

    2013-01-01

    Background In order to benefit from the highly conformal irradiation of tumors in ion radiotherapy, sophisticated treatment planning and simulation are required. The purpose of this study was to investigate the potential of MRI for ion radiotherapy treatment plan simulation and adaptation using a classification-based approach. Methods Firstly, a voxelwise tissue classification was applied to derive pseudo CT numbers from MR images using up to 8 contrasts. Appropriate MR sequences and parameters were evaluated in cross-validation studies of three phantoms. Secondly, ion radiotherapy treatment plans were optimized using both MRI-based pseudo CT and reference CT and recalculated on reference CT. Finally, a target shift was simulated and a treatment plan adapted to the shift was optimized on a pseudo CT and compared to reference CT optimizations without plan adaptation. Results The derivation of pseudo CT values led to mean absolute errors in the range of 81 - 95 HU. Most significant deviations appeared at borders between air and different tissue classes and originated from partial volume effects. Simulations of ion radiotherapy treatment plans using pseudo CT for optimization revealed only small underdosages in distal regions of a target volume with deviations of the mean dose of PTV between 1.4 - 3.1% compared to reference CT optimizations. A plan adapted to the target volume shift and optimized on the pseudo CT exhibited a comparable target dose coverage as a non-adapted plan optimized on a reference CT. Conclusions We were able to show that a MRI-based derivation of pseudo CT values using a purely statistical classification approach is feasible although no physical relationship exists. Large errors appeared at compact bone classes and came from an imperfect distinction of bones and other tissue types in MRI. In simulations of treatment plans, it was demonstrated that these deviations are comparable to uncertainties of a target volume shift of 2 mm in two directions

  5. Assessing the quality of conformal treatment planning: a new tool for quantitative comparison.

    PubMed

    Menhel, J; Levin, D; Alezra, D; Symon, Z; Pfeffer, R

    2006-10-21

    We develop a novel radiotherapy plan comparison index, critical organ scoring index (COSI), which is a measure of both target coverage and critical organ overdose. COSI is defined as COSI=1-(V(OAR)>tol/TC), where V(OAR)>tol is the fraction of volume of organ at risk receiving more than tolerance dose, and TC is the target coverage, VT,PI/VT, where VT,PI is the target volume receiving at a least prescription dose and VT is the total target volume. COSI approaches unity when the critical structure is completely spared and the target coverage is unity. We propose a two-dimensional, graphical representation of COSI versus conformity index (CI), where CI is a measure of a normal tissue overdose. We show that this 2D representation is a reliable, visual quantitative tool for evaluating competing plans. We generate COSI-CI plots for three sites: head and neck, cavernous sinus, and pancreas, and evaluate competing non-coplanar 3D and IMRT treatment plans. For all three sites this novel 2D representation assisted the physician in choosing the optimal plan, both in terms of target coverage and in terms of critical organ sparing. We verified each choice by analysing individual DVHs and isodose lines. Comparing our results to the widely used conformation number, we found that in all cases where there were discrepancies in the choice of the best treatment plan, the COSI-CI choice was considered the correct one, in several cases indicating that a non-coplanar 3D plan was superior to the IMRT plans. The choice of plan was quick, simple and accurate using the new graphical representation. PMID:17019044

  6. Conformal radiotherapy in the adjuvant treatment of gastric cancer: Review of 82 cases

    SciTech Connect

    Kassam, Zahra |; Lockwood, Gina |; O'Brien, Catherine; Brierley, James |; Swallow, Carol ||; Oza, Amit |; Siu, Lillian |; Knox, Jennifer J. |; Wong, Rebecca |; Cummings, Bernard; Kim, John |; Moore, Malcolm |; Ringash, Jolie |. E-mail: jolie.ringash@rmp.uhn.on.cag

    2006-07-01

    Background: The Intergroup 0116 study showed a survival benefit with adjuvant chemoradiotherapy (CRT) for resected gastric cancer. We report our experience using conformal radiotherapy (RT). Methods and Materials: Eighty-two patients with resected gastric or gastroesophageal junction (GEJ) adenocarcinoma, Stage IB to IV (M0), were treated with 45 Gy in 25 fractions using a 5-field conformal technique. Chemotherapy was in accordance with the Intergroup 0116 study, or infusional 5-fluorouracil and cisplatin in a phase I/II trial. Results: Mean age was 56.4 years. Median follow-up was 22.8 months. Grade 3 or greater acute toxicity (National Cancer Institute Common Terminology Criteria of Adverse Events, version 3.0) was noted in 57% of patients (upper gastrointestinal tract 34%, hematologic 33%). One patient died of neutropenic sepsis. Radiation Therapy Oncology Group Grade 3 late toxicity included esophageal strictures (3 patients) and small bowel obstruction (1 patient). Full course CRT was completed by 67% of patients. Of 26 patients who relapsed, 20 died. Site of first relapse was available on 23 patients: 8 locoregional and distant, 4 locoregional alone, 11 distant alone. Overall and relapse-free survival were 69% and 54% at 3 years. Conclusion: Adjuvant CRT for gastric cancer, even with conformal RT, is associated with significant toxicity. Survival was comparable to that reported in the Intergroup 0116 study.

  7. Combined Proton and Photon Conformal Radiotherapy for Intracranial Atypical and Malignant Meningioma

    SciTech Connect

    Boskos, Christos Feuvret, Loic; Noel, Georges; Habrand, Jean-Louis; Pommier, Pascal; Alapetite, Claire; Mammar, Hamid; Ferrand, Regis; Boisserie, Gilbert; Mazeron, Jean-Jacques

    2009-10-01

    Purpose: To evaluate retrospectively the efficacy of conformal fractionated radiotherapy combining proton and photon beams after primary surgery for treatment of atypical and malignant meningiomas. Patients and Methods: Between September 1999 and October 2006, 24 patients (12 male, 12 female) with histopathologically proven meningioma (atypical 19, malignant 5) received postoperative combined radiotherapy with a 201-MeV proton beam at the Centre Protontherapie d'Orsay and a high-energy photon beam. Six patients underwent gross total resection and 18 a subtotal resection. Median gross tumor volume and clinical target volume were 44.7 cm{sup 3} and 153.3 cm{sup 3}, respectively. Mean total irradiation dose was 65.01 CGE (cobalt gray equivalent), with a mean proton total dose of 34.05 CGE and a mean photon total dose 30.96 CGE. Results: The median (range) follow-up interval was 32.2 (1-72) months. The overall mean local relapse-free interval was 27.2 (10-50) months, 28.3 (10-50) months for atypical meningioma and 23 (13-33) months for malignant meningioma. Ten tumors recurred locally. One-, 2-, 3-, 4-, 5-, and 8- year local control rates for the entire group of patients were 82.9% {+-} 7.8%, 82.9% {+-} 7.8%, 61.3% {+-} 11%, 61.3% {+-} 11%, 46.7% {+-} 12.3%, and 46.7% {+-} 12.3%, respectively. One-, 2-, 3-, 4-, 5-, and 8- year overall survival rates were 100%, 95.5% {+-} 4.4%, 80.4% {+-} 8.8%, 65.3% {+-} 10.6%, 53.2% {+-} 11.6%, and 42.6% {+-} 13%, respectively. Survival was significantly associated with total dose. There was no acute morbidity of radiotherapy. One patient developed radiation necrosis 16 months after treatment. Conclusions: Postoperative combination of conformal radiotherapy with protons and photons for atypical and malignant meningiomas is a well-tolerated treatment producing long-term tumor stabilization.

  8. Electron Density Calibration for Radiotherapy Treatment Planning

    SciTech Connect

    Herrera-Martinez, F.; Rodriguez-Villafuerte, M.; Martinez-Davalos, A.; Ruiz-Trejo, C.; Celis-Lopez, M. A.; Larraga-Gutierrez, J. M.; Garcia-Garduno, A.

    2006-09-08

    Computed tomography (CT) images are used as basic input data for most modern radiosurgery treatment planning systems (TPS). CT data not only provide anatomic information to delineate target volumes, but also allow the introduction of corrections for tissue inhomogeneities into dose calculations during the treatment planning procedure. These corrections involve the determination of a relationship between tissue electron density ({rho}e) and their corresponding Hounsfield Units (HU). In this work, an elemental analysis of different commercial tissue equivalent materials using Scanning Electron Microscopy was carried out to characterize their chemical composition. The tissue equivalent materials were chosen to ensure a large range of {rho}e to be included in the CT scanner calibration. A phantom was designed and constructed with these materials to simulate the size of a human head.

  9. Electron Density Calibration for Radiotherapy Treatment Planning

    NASA Astrophysics Data System (ADS)

    Herrera-Martínez, F.; Rodríguez-Villafuerte, M.; Martínez-Dávalos, A.; Ruiz-Trejo, C.; Celis-López, M. A.; Lárraga-Gutiérrez, J. M.; García-Garduño, A.

    2006-09-01

    Computed tomography (CT) images are used as basic input data for most modern radiosurgery treatment planning systems (TPS). CT data not only provide anatomic information to delineate target volumes, but also allow the introduction of corrections for tissue inhomogeneities into dose calculations during the treatment planning procedure. These corrections involve the determination of a relationship between tissue electron density (ρe) and their corresponding Hounsfield Units (HU). In this work, an elemental analysis of different commercial tissue equivalent materials using Scanning Electron Microscopy was carried out to characterize their chemical composition. The tissue equivalent materials were chosen to ensure a large range of ρe to be included in the CT scanner calibration. A phantom was designed and constructed with these materials to simulate the size of a human head.

  10. Volumetric Modulation Arc Radiotherapy With Flattening Filter-Free Beams Compared With Static Gantry IMRT and 3D Conformal Radiotherapy for Advanced Esophageal Cancer: A Feasibility Study

    SciTech Connect

    Nicolini, Giorgia; Ghosh-Laskar, Sarbani; Shrivastava, Shyam Kishore; Banerjee, Sushovan; Chaudhary, Suresh; Agarwal, Jai Prakash; Munshi, Anusheel; Clivio, Alessandro; Fogliata, Antonella; Mancosu, Pietro; Vanetti, Eugenio; Cozzi, Luca

    2012-10-01

    Purpose: A feasibility study was performed to evaluate RapidArc (RA), and the potential benefit of flattening filter-free beams, on advanced esophageal cancer against intensity-modulated radiotherapy (IMRT) and three-dimensional conformal radiotherapy (3D-CRT). Methods and Materials: The plans for 3D-CRT and IMRT with three to seven and five to seven fixed beams were compared against double-modulated arcs with avoidance sectors to spare the lungs for 10 patients. All plans were optimized for 6-MV photon beams. The RA plans were studied for conventional and flattening filter-free (FFF) beams. The objectives for the planning target volume were the volume receiving {>=}95% or at most 107% of the prescribed dose of <1% with a dose prescription of 59.4 Gy. For the organs at risk, the lung volume (minus the planning target volume) receiving {>=}5 Gy was <60%, that receiving 20 Gy was <20%-30%, and the mean lung dose was <15.0 Gy. The heart volume receiving 45 Gy was <20%, volume receiving 30 Gy was <50%. The spinal dose received by 1% was <45 Gy. The technical delivery parameters for RA were assessed to compare the normal and FFF beam characteristics. Results: RA and IMRT provided equivalent coverage and homogeneity, slightly superior to 3D-CRT. The conformity index was 1.2 {+-} 0.1 for RA and IMRT and 1.5 {+-} 0.2 for 3D-CRT. The mean lung dose was 12.2 {+-} 4.5 for IMRT, 11.3 {+-} 4.6 for RA, and 10.8 {+-} 4.4 for RA with FFF beams, 18.2 {+-} 8.5 for 3D-CRT. The percentage of volume receiving {>=}20 Gy ranged from 23.6% {+-} 9.1% to 21.1% {+-} 9.7% for IMRT and RA (FFF beams) and 39.2% {+-} 17.0% for 3D-CRT. The heart and spine objectives were met by all techniques. The monitor units for IMRT and RA were 457 {+-} 139, 322 {+-} 20, and 387 {+-} 40, respectively. RA with FFF beams showed, compared with RA with normal beams, a {approx}20% increase in monitor units per Gray, a 90% increase in the average dose rate, and 20% reduction in beam on time (owing to different

  11. Functional and molecular image guidance in radiotherapy treatment planning optimization.

    PubMed

    Das, Shiva K; Ten Haken, Randall K

    2011-04-01

    Functional and molecular imaging techniques are increasingly being developed and used to quantitatively map the spatial distribution of parameters, such as metabolism, proliferation, hypoxia, perfusion, and ventilation, onto anatomically imaged normal organs and tumor. In radiotherapy optimization, these imaging modalities offer the promise of increased dose sparing to high-functioning subregions of normal organs or dose escalation to selected subregions of the tumor as well as the potential to adapt radiotherapy to functional changes that occur during the course of treatment. The practical use of functional/molecular imaging in radiotherapy optimization must take into cautious consideration several factors whose influences are still not clearly quantified or well understood including patient positioning differences between the planning computed tomography and functional/molecular imaging sessions, image reconstruction parameters and techniques, image registration, target/normal organ functional segmentation, the relationship governing the dose escalation/sparing warranted by the functional/molecular image intensity map, and radiotherapy-induced changes in the image intensity map over the course of treatment. The clinical benefit of functional/molecular image guidance in the form of improved local control or decreased normal organ toxicity has yet to be shown and awaits prospective clinical trials addressing this issue. PMID:21356479

  12. Target Volume Delineation for Partial Breast Radiotherapy Planning: Clinical Characteristics Associated with Low Interobserver Concordance

    SciTech Connect

    Petersen, Ross P.; Truong, Pauline T. Kader, Hosam A.; Berthelet, Eric; Lee, Junella C.; Hilts, Michelle L.; Kader, Adam S.; Beckham, Wayne A.; Olivotto, Ivo A.

    2007-09-01

    Purpose: To examine variability in target volume delineation for partial breast radiotherapy planning and evaluate characteristics associated with low interobserver concordance. Methods and Materials: Thirty patients who underwent planning CT for adjuvant breast radiotherapy formed the study cohort. Using a standardized scale to score seroma clarity and consensus contouring guidelines, three radiation oncologists independently graded seroma clarity and delineated seroma volumes for each case. Seroma geometric center coordinates, maximum diameters in three axes, and volumes were recorded. Conformity index (CI), the ratio of overlapping volume and encompassing delineated volume, was calculated for each case. Cases with CI {<=}0.50 were analyzed to identify features associated with low concordance. Results: The median time from surgery to CT was 42.5 days. For geometric center coordinates, variations from the mean were 0.5-1.1 mm and standard deviations (SDs) were 0.5-1.8 mm. For maximum seroma dimensions, variations from the mean and SDs were predominantly <5 mm, with the largest SDs observed in the medial-lateral axis. The mean CI was 0.61 (range, 0.27-0.84). Five cases had CI {<=}0.50. Conformity index was significantly associated with seroma clarity (p < 0.001) and seroma volume (p < 0.002). Features associated with reduced concordance included tissue stranding from the surgical cavity, proximity to muscle, dense breast parenchyma, and benign calcifications that may be mistaken for surgical clips. Conclusion: Variability in seroma contouring occurred in three dimensions, with the largest variations in the medial-lateral axis. Awareness of clinical features associated with reduced concordance may be applied toward training staff and refining contouring guidelines for partial breast radiotherapy trials.

  13. SU-E-T-348: Verification MU Calculation for Conformal Radiotherapy with Multileaf Collimator Using Report AAPM TG 114

    SciTech Connect

    Adrada, A; Tello, Z; Medina, L; Garrigo, E; Venencia, D

    2014-06-01

    Purpose: The purpose of this work was to develop and validate an open source independent MU dose calculation software for 3D conformal radiotherapy with multileaf high and low resolution according to the report of AAPM TG 11 Methods: Treatment plans were done using Iplan v4.5 BrainLAB TPS. A 6MV photon beam produced by Primus and Novalis linear accelerators equipped with an Optifocus MLC and HDMLC, respectively. TPS dose calculation algorithms were pencil beam and Monte Carlo. 1082 treatments plans were selected for the study. The algorithm was written in free and open source CodeBlocks C++ platform. Treatment plans were imported by the software using RTP format. Equivalent size field is obtained from the positions of the leaves; the effective depth of calculation can be introduced by TPS's dosimetry report or automatically calculated starting from SSD. The inverse square law is calculated by the 3D coordinates of the isocenter and normalization point of the treatment plan. The dosimetric parameters TPR, Sc, Sp and WF are linearly interpolated. Results: 1082 plans of both machines were analyzed. The average uncertainty between the TPS and the independent calculation was −0.43% ± 2.42% [−7.90%, 7.50%]. Specifically for the Primus the variation obtained was −0.85% ± 2.53% and for the Novalis 0.00% ± 2.23%. Data show that 94.8% of the cases the uncertainty was less than or equal to 5%, while 98.9% is less than or equal to 6%. Conclusion: The developed software is appropriate for use in calculation of UM. This software can be obtained upon request.

  14. Strategies to evaluate the impact of rectal volume on prostate motion during three-dimensional conformal radiotherapy for prostate cancer*

    PubMed Central

    Poli, Ana Paula Diniz Fortuna; Dias, Rodrigo Souza; Giordani, Adelmo José; Segreto, Helena Regina Comodo; Segreto, Roberto Araujo

    2016-01-01

    Objective To evaluate the rectal volume influence on prostate motion during three-dimensional conformal radiotherapy (3D-CRT) for prostate cancer. Materials and Methods Fifty-one patients with prostate cancer underwent a series of three computed tomography scans including an initial planning scan and two subsequent scans during 3D-CRT. The organs of interest were outlined. The prostate contour was compared with the initial CT images considering the anterior, posterior, superior, inferior and lateral edges of the organ. Variations in the anterior limits and volume of the rectum were assessed and correlated with prostate motion in the anteroposterior direction. Results The maximum range of prostate motion was observed in the superoinferior direction, followed by the anteroposterior direction. A significant correlation was observed between prostate motion and rectal volume variation (p = 0.037). A baseline rectal volume superior to 70 cm3 had a significant influence on the prostate motion in the anteroposterior direction (p = 0.045). Conclusion The present study showed a significant interfraction motion of the prostate during 3D-CRT with greatest variations in the superoinferior and anteroposterior directions, and that a large rectal volume influences the prostate motion with a cutoff value of 70 cm3. Therefore, the treatment of patients with a rectal volume > 70 cm3 should be re-planned with appropriate rectal preparation. PMID:26929456

  15. Three-Dimensional Conformal Radiotherapy for Hepatocellular Carcinoma in Patients Unfit for Resection, Ablation, or Chemotherapy: A Retrospective Study

    PubMed Central

    Mosa, Eftychia; Georgakopoulos, John; Platoni, Kalliopi; Brountzos, Ilias; Zygogianni, Anna; Kosmidis, Paraskevas; Mystakidou, Kyriaki; Tolia, Maria; Beli, Ivelina; Gouliamos, Athanasios; Kouvaris, John; Kelekis, Nikoalos

    2013-01-01

    Purpose. The purpose is to evaluate the feasibility, efficacy, and the toxicity of three-dimensional conformal radiotherapy (3DCRT) in patients with advanced hepatocelluar carcinoma (HCC) and inferior vena cava tumor thrombosis (IVCTT). Methods. Between 2007 and 2012, in a retrospective way, 9 patients (median age 69 years) with advanced HCC and IVCTT unfit for surgery, radiofrequency ablation, embolization, or chemotherapy were treated with three-dimensional conformal radiotherapy (3DCRT). The radiotherapy volume included both primary tumor and IVTT. The radiotherapy schedule was 50–52 Gy in 2 Gy fractions. Overall survival (OS), response to radiotherapy, visual analogue scale (VAS), and toxicity were assessed. Results. All patients demonstrated a response rate up to 60%. During radiotherapy, 3 patients experienced grade 1 nausea/vomit toxicity. All patients demonstrated an elevation of the liver enzymes (3 patients with grade 1 and 6 patients with grade 2). The mean VAS-score was decreased from 6.11 to 3.11, while the median overall survival was 24 months. Conclusion. 3DCRT achieves a very high local control rate and is suitable for patients with HCC and IVTT, while the documented radiation induced toxicity is moderate. It can be recommended for palliation in patients unable to undergo curative therapies. PMID:24379750

  16. Postoperative External Beam Radiotherapy for Differentiated Thyroid Cancer: Outcomes and Morbidity With Conformal Treatment

    SciTech Connect

    Schwartz, David L. Lobo, Mark J.; Ang, K. Kian; Morrison, William H.; Rosenthal, David I.; Ahamad, Anesa; Evans, Douglas B.; Clayman, Gary; Sherman, Steven I.; Garden, Adam S.

    2009-07-15

    Purpose: To review institutional outcomes for patients treated for differentiated thyroid cancer with postoperative conformal external beam radiotherapy (EBRT). Methods and Materials: This is a single-institution retrospective review of 131 consecutive patients with differentiated thyroid cancer who underwent EBRT between January 1996 and December 2005. Histologic diagnoses included 104 papillary, 21 follicular, and six mixed papillary-follicular types. American Joint Committee on Cancer stage distribution was Stage III in 2 patients, Stage IVa-IVc in 128, and not assessable in 1. Thirty-four patients (26%) had high-risk histologic types and 76 (58%) had recurrent disease. Extraglandular disease spread was seen in 126 patients (96%), microscopically positive surgical margins were seen in 62 patients (47%), and gross residual disease was seen in 15 patients (11%). Median EBRT dose was 60 Gy (range, 38-72 Gy). Fifty-seven patients (44%) were treated with intensity-modulated radiotherapy (IMRT) to a median dose of 60 Gy (range, 56-66 Gy). Median follow-up was 38 months (range, 0-134 months). Results: Kaplan-Meier estimates of locoregional relapse-free survival, disease-specific survival, and overall survival at 4 years were 79%, 76%, and 73%, respectively. On multivariate analysis, high-risk histologic features and gross residual disease predicted for inferior locoregional relapse-free survival, whereas high-risk histologic features, M1 disease, and gross residual disease predicted for inferior disease-specific and overall survival. The IMRT did not impact on survival outcomes, but was associated with less frequent severe late morbidity (12% vs. 2%). Conclusions: Postoperative conformal EBRT provides durable locoregional disease control for patients with high-risk differentiated thyroid cancer if disease is reduced to microscopic burden. Patients with gross disease face significantly worse outcomes. The IMRT may significantly reduce chronic radiation morbidity, but

  17. Visual Outcome and Tumor Control After Conformal Radiotherapy for Patients With Optic Nerve Sheath Meningioma

    SciTech Connect

    Arvold, Nils D.; Lessell, Simmons; Bussiere, Marc; Beaudette, Kevin; Rizzo, Joseph F.; Loeffler, Jay S.; Shih, Helen A.

    2009-11-15

    Purpose: Optic nerve sheath meningioma (ONSM) is a rare tumor that almost uniformly leads to visual dysfunction and even blindness without intervention. Because surgical extirpation carries a high risk of postoperative blindness, vision-sparing treatment strategies are desirable. Methods and Materials: We retrospectively reviewed the outcomes of 25 patients (25 optic nerves) with ONSM, treated at a single institution with conformal fractionated radiotherapy by either stereotactic photon or proton radiation. Primary endpoints were local control and visual acuity. Results: The patients presented with symptoms of visual loss (21) or orbital pain (3) or were incidentally diagnosed by imaging (3). The mean age was 44 years, and 64% were female patients. The indication for treatment was the development or progression of symptoms. Of the patients, 13 were treated with photons, 9 were treated with protons, and 3 received a combination of photons and protons. The median dose delivered was 50.4 gray equivalents (range, 45-59.4 gray equivalents). Median follow-up after radiotherapy was 30 months (range, 3-168 months), with 3 patients lost to follow-up. At most recent follow-up, 21 of 22 patients (95%) had improved (14) or stable (7) visual acuity. One patient had worsened visual acuity after initial postirradiation improvement. Of the 22 patients, 20 (95%) had no radiographic progression. Three patients had evidence of asymptomatic, limited retinopathy on ophthalmologic examination, and one had recurrent ONSM 11 years after treatment. Conclusions: Highly conformal, fractionated radiation therapy for symptomatic primary ONSM provides tumor control and improvement in visual function in most cases, with minimal treatment-induced morbidity. Longer follow-up is needed to assess the durability of tumor control and treatment-related late effects.

  18. The Risk of Early and Late Lung Sequelae After Conformal Radiotherapy in Breast Cancer Patients

    SciTech Connect

    Kahan, Zsuzsanna . E-mail: kahan@onko.szote.u-szeged.hu; Csenki, Melinda; Varga, Zoltan; Szil, Elemer; Cserhati, Adrienn; Balogh, Attila; Gyulai, Zsofia; Mandi, Yvette; Boda, Krisztina; Thurzo, Laszlo

    2007-07-01

    Purpose: To study the risks of early and late radiogenic lung damage in breast cancer patients after conformal radiotherapy. Methods and Materials: Radiogenic lung sequelae were assessed prospectively in 119 patients by means of clinical signs, radiologic abnormalities, and the mean density change (MDC) of the irradiated lung on CT. Results: Significant positive associations were detected between the development of lung abnormalities 3 months or 1 year after the radiotherapy and the age of the patient, the ipsilateral mean lung dose (MLD), the radiation dose to 25% of the ipsilateral lung (D{sub 25%}) and the volume of the ipsilateral lung receiving 20 Gy (V{sub 20Gy}). The irradiation of the axillary and supraclavicular lymph nodes favored the development of pneumonitis but not that of fibrosis. No relation was found between the preradiotherapy plasma TGF-{beta} level and the presence of radiogenic lung damage. At both time points, MDC was strongly related to age. Significant positive associations were demonstrated between the risks of pneumonitis or fibrosis and the age of the patient, MLD, D{sub 25%}, and V{sub 20Gy}. A synergistic effect of MLD, D{sub 25%}, and V{sub 20Gy} with age in patients older than 59 years is suggested. Conclusion: Our analyses indicate that the risks of early and late radiogenic lung sequelae are strongly related to the age of the patient, the volume of the irradiated lung, and the dose to it.

  19. RapidArc radiotherapy planning for prostate cancer: Single-arc and double-arc techniques vs. intensity-modulated radiotherapy

    SciTech Connect

    Sze, Henry C.K.; Lee, Michael C.H.; Hung, Wai-Man; Yau, Tsz-Kok; Lee, Anne W.M.

    2012-04-01

    RapidArc is a novel technique using arc radiotherapy aiming to achieve intensity-modulated radiotherapy (IMRT)-quality radiotherapy plans with shorter treatment time. This study compared the dosimetric quality and treatment efficiency of single-arc (SA) vs. double-arc (DA) and IMRT in the treatment of prostate cancer. Fourteen patients were included in the analysis. The planning target volume (PTV), which contained the prostate gland and proximal seminal vesicles, received 76 Gy in 38 fractions. Seven-field IMRT, SA, and DA plans were generated for each patient. Dosimetric quality in terms of the minimum PTV dose, PTV hotspot, inhomogeneity, and conformity index; and sparing of rectum, bladder, and femoral heads as measured by V70, V-40, and V20 (% of volume receiving >70 Gy, 40 Gy, and 20 Gy, respectively), treatment efficiency as assessed by monitor units (MU) and treatment time were compared. All plan objectives were met satisfactorily by all techniques. DA achieved the best dosimetric quality with the highest minimum PTV dose, lowest hotspot, and the best homogeneity and conformity. It was also more efficient than IMRT. SA achieved the highest treatment efficiency with the lowest MU and shortest treatment time. The mean treatment time for a 2-Gy fraction was 4.80 min, 2.78 min, and 1.30 min for IMRT, DA, and SA, respectively. However, SA also resulted in the highest rectal dose. DA could improve target volume coverage and reduce treatment time and MU while maintaining equivalent normal tissue sparing when compared with IMRT. SA achieved the greatest treatment efficiency but with the highest rectal dose, which was nonetheless within tolerable limits. For busy units with high patient throughput, SA could be an acceptable option.

  20. Survey of Stereotactic Body Radiation Therapy in Japan by the Japan 3-D Conformal External Beam Radiotherapy Group

    SciTech Connect

    Nagata, Yasushi Hiraoka, Masahiro; Mizowaki, Takashi; Narita, Yuichiro; Matsuo, Yukinori; Norihisa, Yoshiki; Onishi, Hiroshi; Shirato, Hiroki

    2009-10-01

    Purpose: To recognize the current status of stereotactic body radiotherapy (SBRT) in Japan, using a nationwide survey conducted by the Japan 3-D Conformal External Beam Radiotherapy Group. Methods and Materials: The questionnaire was sent by mail to 117 institutions. Ninety-four institutions (80%) responded by the end of November 2005. Fifty-three institutions indicated that they have already started SBRT, and 38 institutions had been reimbursed by insurance. Results: A total of 1111 patients with histologically confirmed lung cancer were treated. Among these patients, 637 had T1N0M0 and 272 had T2N0M0 lung cancer. Metastatic lung cancer was found in 702 and histologically unconfirmed lung tumor in 291 patients. Primary liver cancer was found in 207 and metastatic liver cancer in 76 patients. The most frequent schedule used for primary lung cancer was 48Gy in 4 fractions at 22 institutions (52%), followed by 50Gy in 5 fractions at 11 institutions (26%) and 60Gy in 8 fractions at 4 institutions (10%). The tendency was the same for metastatic lung cancer. The average number of personnel involved in SBRT was 1.8 radiation oncologists, including 1.1 certified radiation oncologists, 2.8 technologists, 0.7 nurses, and 0.6 certified quality assurance personnel and 0.3 physicists. The most frequent amount of time for treatment planning was 61-120min, for quality assurance was 50-60min, and for treatment was 30min. There were 14 (0.6% of all cases) reported Grade 5 complications: 11 cases of radiation pneumonitis, 2 cases of hemoptysis, and 1 case of radiation esophagitis. Conclusion: The current status of SBRT in Japan was surveyed.

  1. Preoperative radiotherapy in gastric cancer: CTV definition for conformal therapy according to tumor location.

    PubMed

    Cellini, Francesco; Valentini, Vincenzo; Pacelli, Fabio; D'Ugo, Domenico; Mantini, Giovanna; Balducci, Mario; Gambacorta, Maria Antonietta; Nori, Stefania

    2003-01-01

    In the past radiation oncologists had not a major interest in the treatment of gastric cancer, but the positive outcomes of the Intergroup Study (INT-0116) supported the role of locoregional control in promoting better survival. To reduce the toxicity and the risk of residual disease in locally advanced tumors after surgery,a preoperative approach was tentatively considered. The aim of this manuscript is to define the location of nodal area at risk for cancer involvement according to the tumor location (cardias, corpus, antrum) on CT images to help the radiotherapist in the contouring process of the CTV for preoperative conformal treatment of gastric cancer. The analysis of both the percentage of nodal involvement detected at surgery and of the site of recurrence after radical surgery can direct to the areas to be considered at risk with its contouring on CT. Preoperative conformal-three dimensional radiotherapy of gastric cancer requires clear and well defined contouring guide-lines to allow the evaluation of clinical outcomes and the analysis if the area at risk for recurrence has changed after the preoperative approach. PMID:15018320

  2. Improved Planning Time and Plan Quality Through Multicriteria Optimization for Intensity-Modulated Radiotherapy

    SciTech Connect

    Craft, David L.; Hong, Theodore S.; Shih, Helen A.; Bortfeld, Thomas R.

    2012-01-01

    Purpose: To test whether multicriteria optimization (MCO) can reduce treatment planning time and improve plan quality in intensity-modulated radiotherapy (IMRT). Methods and Materials: Ten IMRT patients (5 with glioblastoma and 5 with locally advanced pancreatic cancers) were logged during the standard treatment planning procedure currently in use at Massachusetts General Hospital (MGH). Planning durations and other relevant planning information were recorded. In parallel, the patients were planned using an MCO planning system, and similar planning time data were collected. The patients were treated with the standard plan, but each MCO plan was also approved by the physicians. Plans were then blindly reviewed 3 weeks after planning by the treating physician. Results: In all cases, the treatment planning time was vastly shorter for the MCO planning (average MCO treatment planning time was 12 min; average standard planning time was 135 min). The physician involvement time in the planning process increased from an average of 4.8 min for the standard process to 8.6 min for the MCO process. In all cases, the MCO plan was blindly identified as the superior plan. Conclusions: This provides the first concrete evidence that MCO-based planning is superior in terms of both planning efficiency and dose distribution quality compared with the current trial and error-based IMRT planning approach.

  3. Optimized radiotherapy treatment planning using the Complication Probability Factor (CPF)

    SciTech Connect

    Wolbarst, A.B.; Sternick, E.S.; Curran, B.H.; Dritschilo, A.

    1980-06-01

    A major obstacle to effective computerized optimization of radiotherapy treatment planning has been the lack of a biologically meaningful and clinically useful objective function. Our approach employs a Complication Probability Factor (CPF) based directly on radiobiological principles and clinical data. The CPF measures the likelihood that a given dose distribution will lead to serious complications in the patient as a result of damage to healthy tissue. A computerized search can be made for a treatment plan which delivers an acceptable tumoricidal dose, yet minimizes the CPF as averaged over the total volume of healthy tissue irradiated. The program is run on a PDP 11/55 in conjunction with a commercial treatment planning package.

  4. Three-Dimensional Non-Coplanar Conformal Radiotherapy Yields Better Results Than Traditional Beam Arrangements for Adjuvant Treatment of Gastric Cancer

    SciTech Connect

    Soyfer, Viacheslav Corn, Benjamin W.; Melamud, Alex B.S.; Alani, Shlomi; Tempelhof, Haim; Agai, Reuben; Shmueli, Anat; Figer, Arie; Kovner, Felix

    2007-10-01

    Purpose: The current standard of adjuvant treatment for gastric cancer after curative resection is concurrent administration of radiotherapy and 5-fluorouracil-based chemotherapy. The radiation fields are often arranged as anterioposterior-posteroanterior opposed parallel fields with general recommendations for sparing at least two-thirds of one kidney. We investigated whether a better radiation distribution would be achievable with three-dimensional conformal approaches compared with the classic anterioposterior-posteroanterior fields. Methods and Materials: A total of 19 patients with adenocarcinoma of the stomach were treated with adjuvant chemoradiotherapy using a non-coplanar four-field arrangement. In each case, parallel planning using an anterioposterior-posteroanterior arrangement and a four-field 'box' was performed, and the generated plans were subsequently compared for coverage of target volumes and doses to irradiated organs next to the tumor bed. A separate analysis was performed for kidneys exposed to greater and lower doses in each patient. The mean radiation dose and percentage of kidney volume receiving a dose >20 Gy were registered. Statistical analysis was performed using the two-tailed t test. Results: The clinical target volume was adequately covered in all three plans. In the greater-dose kidney group, all the differences were statistically significant with a benefit for the three-dimensional plan. In the lower-dose kidney group, the differences in the mean radiation dose did not reach the level of statistical significance, and the differences in the kidney volume receiving a dose >20 Gy showed a statistically significant benefit for the three-dimensional plan. Conclusion: Non-coplanar three-dimensional-based conformal planning for postoperative radiotherapy for gastric cancer provided the best results regarding kidney and spinal cord exposure with adequate clinical target volume coverage. This technique was readily implemented in clinical

  5. The role of PET/CT scanning in radiotherapy planning.

    PubMed

    Jarritt, P H; Carson, K J; Hounsell, A R; Visvikis, D

    2006-09-01

    The introduction of functional data into the radiotherapy treatment planning process is currently the focus of significant commercial, technical, scientific and clinical development. The potential of such data from positron emission tomography (PET) was recognized at an early stage and was integrated into the radiotherapy treatment planning process through the use of image fusion software. The combination of PET and CT in a single system (PET/CT) to form an inherently fused anatomical and functional dataset has provided an imaging modality which could be used as the prime tool in the delineation of tumour volumes and the preparation of patient treatment plans, especially when integrated with virtual simulation. PET imaging typically using 18F-Fluorodeoxyglucose (18F-FDG) can provide data on metabolically active tumour volumes. These functional data have the potential to modify treatment volumes and to guide treatment delivery to cells with particular metabolic characteristics. This paper reviews the current status of the integration of PET and PET/CT data into the radiotherapy treatment process. Consideration is given to the requirements of PET/CT data acquisition with reference to patient positioning aids and the limitations imposed by the PET/CT system. It also reviews the approaches being taken to the definition of functional/tumour volumes and the mechanisms available to measure and include physiological motion into the imaging process. The use of PET data must be based upon a clear understanding of the interpretation and limitations of the functional signal. Protocols for the implementation of this development remain to be defined, and outcomes data based upon clinical trials are still awaited. PMID:16980683

  6. Retrospective estimate of the quality of intensity-modulated radiotherapy plans for lung cancer

    NASA Astrophysics Data System (ADS)

    Koo, Jihye; Yoon, Myonggeun; Chung, Weon Kuu; Kim, Dong Wook

    2015-07-01

    This study estimated the planning quality of intensity-modulated radiotherapy in 42 lung cancer cases to provide preliminary data for the development of a planning quality assurance algorithm. Organs in or near the thoracic cavity (ipsilateral lung, contralateral lung, heart, liver, esophagus, spinal cord, and bronchus) were selected as organs at risk (OARs). Radiotherapy plans were compared by using the conformity index (CI), coverage index (CVI), and homogeneity index (HI) of the planning target volume (PTV), the OAR-PTV distance and the OAR-PTV overlap volume, and the V10 Gy , V20 Gy , and equivalent uniform dose (EUD) of the OARs. The CI, CVI, and HI of the PTV were 0.54-0.89 (0.77 ± 0.08), 0.90-1.00 (0.98 ± 0.02), and 0.11-0.41, (0.15 ± 0.05), respectively. The mean EUDs (V10 Gy , V20 Gy ) of the ipsilateral lung, contralateral lung, esophagus, cord, liver, heart, and bronchus were 8.07 Gy (28.06, 13.17), 2.59 Gy (6.53, 1.18), 7.02 Gy (26.17, 12.32), 3.56 Gy (13.56, 4.48), 0.72 Gy (2.15, 0.91), 5.14 Gy (19.68, 8.62), and 10.56 Gy (36.08, 19.79), respectively. EUDs tended to decrease as the OAR-PTV distance increased and the OAR-PTV overlap volume decreased. Because the plans in this study were from a single department, relatively few people were involved in treatment planning. Differences in treatment results for a given patient would be much more pronounced if many departments were involved.

  7. A Low-Dose Ipsilateral Lung Restriction Improves 3-D Conformal Planning for Partial Breast Radiation Therapy

    SciTech Connect

    Mitchell, Tracy; Truong, Pauline T.; Salter, Lee; Graham, Cathy; Gaffney, Helene; Beckham, Wayne; Olivotto, Ivo A.

    2011-04-01

    In trials of 3D conformal external beam partial breast radiotherapy (PBRT), the dosimetrist must balance the priorities of achieving high conformity to the target versus minimizing low-dose exposure to the normal structures. This study highlights the caveat that in the absence of a low-dose lung restriction, the use of relatively en-face fields may meet trial-defined requirements but expose the ipsilateral lung to unnecessary low-dose radiation. Adding a low-dose restriction that {<=}20% of the ipsilateral lung should receive 10% of the prescribed dose resulted in successful plans in 88% of cases. This low-dose lung limit should be used in PBRT planning.

  8. Feasibility of four-dimensional conformal planning for robotic radiosurgery

    SciTech Connect

    Schlaefer, A.; Fisseler, J.; Dieterich, S.; Shiomi, H.; Cleary, K.; Schweikard, A.

    2005-12-15

    Organ motion can have a severe impact on the dose delivered by radiation therapy, and different procedures have been developed to address its effects. Conventional techniques include breath hold methods and gating. A different approach is the compensation for target motion by moving the treatment beams synchronously. Practical results have been reported for robot based radiosurgery, where a linear accelerator mounted on a robotic arm delivers the dose. However, not all organs move in the same way, which results in a relative motion of the beams with respect to the body and the tissues in the proximity of the tumor. This relative motion can severely effect the dose delivered to critical structures. We propose a method to incorporate motion in the treatment planning for robotic radiosurgery to avoid potential overdosing of organs surrounding the target. The method takes into account the motion of all considered volumes, which is discretized for dose calculations. Similarly, the beam motion is taken into account and the aggregated dose coefficient over all discrete steps is used for planning. We simulated the treatment of a moving target with three different planning methods. First, we computed beam weights based on a 3D planning situation and simulated treatment with organ motion and the beams moving synchronously to the target. Second, beam weights were computed by the 4D planning method incorporating the organ and beam motion and treatment was simulated for beams moving synchronously to the target. Third, the beam weights were determined by the 4D planning method with the beams fixed during planning and simulation. For comparison we also give results for the 3D treatment plan if there was no organ motion and when the plan is delivered by fixed beams in the presence of organ motion. The results indicate that the new 4D method is preferable and can further improve the overall conformality of motion compensated robotic radiosurgery.

  9. SU-E-T-393: Investigation of Hot Spots in Tomotherapy 3D Conformal Breast Plan

    SciTech Connect

    Chen, Q; Siebers, J; Khandelwal, S

    2014-06-01

    Purpose: The purpose of this study is to determine the root-cause of hotspots inherent to Tomotherapy static beam 3D conformal radiotherapy (3DCRT) for breast treatment. ASTRO (ref here) recommends that IMRT be avoided for breast treatments. Despite Tomotherapy's inherent IMRT-like optimization and delivery, our experience at a Tomotherapy-only site has been that Tomotherapy 3DCRT fail to produce a clinically acceptable plan for 79% of our breast patients. Hot-spots have been one of the major obstacles. Methods: Eight lumpectomy patients were planned according to RTOG-1005 specification. Two or four tangential beams were used for 3DCRT breast planning. To spare the contralateral breast and ipsilateral lung, part of the PTV was not covered by the primary beam, yielding adjacent hot-spots. We hypothesize that the planning system creates hotspots adjacent to the cold spots to yield scatter radiation dose compensation in the blocked region. Various phantom and patient setup were used to test the hypothesis. Results: Hot spots outside of PTV in the range of 135% - 174% were observed for patient plan. It is confirmed that the PTV partial block causes the adjacent hot spot. The root cause is the optimizer quadratic objective function over- weighs improving the cold spot. The IMRT flexibility offered by Tomotherapy is counter-productive in static-beam 3DCRT breast treatment. For phantom case, as the Modulation-Factor increases from 1.1 to 5, the hot spot increases from 110% to 300%. Limiting the 3DCRT intensity modulation is shown to produce clinically acceptable plan. Conclusion: Most of the hot spots in Tomotherapy 3DCRT breast plan originate from the planning-system optimizer attempting to cover PTV cold spots rather than from the beam energy. Altering the objective function could improve clinical acceptability of static beam Tomotherapy 3DCRT.

  10. Interfraction and Respiratory Organ Motion During Conformal Radiotherapy in Gastric Cancer

    SciTech Connect

    Wysocka, Barbara; Kassam, Zahra; Lockwood, Gina; Brierley, James; Dawson, Laura A.; Buckley, Carol Ann; Jaffray, David; Cummings, Bernard; Kim, John; Wong, Rebecca; Ringash, Jolie

    2010-05-01

    Purpose: To quantify the interfraction and breathing organ motion during adjuvant radiotherapy for gastric cancer and assess organ stability in different breathing states. Methods and Materials: A planning computed tomography (CT) scan and serial study CT scans in free breathing, voluntary inhale and exhale were performed in weeks 1, 3, and 5 of radiotherapy for 22 resected gastric patients. All data sets were fused to register the vertebral bodies. The regions of interest (kidneys, stomach, liver, pancreas, celiac axis, and porta hepatis) or points of interest (POIs; left dome of diaphragm, splenic hilum) were identified. For each region of interest, a POI was automatically placed at the center of mass. The interfraction displacement and breathing amplitude were assessed in the craniocaudal (CC), anteroposterior (AP), and right-left (RL) directions. Results: Comparison of the serial free-breathing CT scans with the planning CT scan showed a median displacement of all POIs of 5.6, 2.2, and 1.8 mm in the CC, AP, and RL directions, respectively. Comparison of the serial inhale scans with the first inhale scan showed a displacement of 4.9, 2.6, and 1.8 mm in the CC, AP, and RL directions, respectively. The comparable values for the exhale scans were 5.1, 2.0, and 1.8 mm. The displacements of the organs were similar in the free breathing, inhale, and exhale states. The median respiratory amplitude in the CC, AP, and RL direction was 14, 4.8, and 1.7 mm, respectively. Conclusion: The median interfraction displacement of the POIs relative to the vertebral bodies was about 6 mm in the CC direction and 2 mm in the other directions. The planning target volume margins need to account for these shifts. Individual assessment of respiratory motion is recommended to identify patients with unusually large respiratory amplitude.

  11. A Monte Carlo dose calculation tool for radiotherapy treatment planning

    NASA Astrophysics Data System (ADS)

    Ma, C.-M.; Li, J. S.; Pawlicki, T.; Jiang, S. B.; Deng, J.; Lee, M. C.; Koumrian, T.; Luxton, M.; Brain, S.

    2002-05-01

    A Monte Carlo user code, MCDOSE, has been developed for radiotherapy treatment planning (RTP) dose calculations. MCDOSE is designed as a dose calculation module suitable for adaptation to host RTP systems. MCDOSE can be used for both conventional photon/electron beam calculation and intensity modulated radiotherapy (IMRT) treatment planning. MCDOSE uses a multiple-source model to reconstruct the treatment beam phase space. Based on Monte Carlo simulated or measured beam data acquired during commissioning, source-model parameters are adjusted through an automated procedure. Beam modifiers such as jaws, physical and dynamic wedges, compensators, blocks, electron cut-outs and bolus are simulated by MCDOSE together with a 3D rectilinear patient geometry model built from CT data. Dose distributions calculated using MCDOSE agreed well with those calculated by the EGS4/DOSXYZ code using different beam set-ups and beam modifiers. Heterogeneity correction factors for layered-lung or layered-bone phantoms as calculated by both codes were consistent with measured data to within 1%. The effect of energy cut-offs for particle transport was investigated. Variance reduction techniques were implemented in MCDOSE to achieve a speedup factor of 10-30 compared to DOSXYZ.

  12. A DICOM based radiotherapy plan database for research collaboration and reporting

    NASA Astrophysics Data System (ADS)

    Westberg, J.; Krogh, S.; Brink, C.; Vogelius, I. R.

    2014-03-01

    Purpose: To create a central radiotherapy (RT) plan database for dose analysis and reporting, capable of calculating and presenting statistics on user defined patient groups. The goal is to facilitate multi-center research studies with easy and secure access to RT plans and statistics on protocol compliance. Methods: RT institutions are able to send data to the central database using DICOM communications on a secure computer network. The central system is composed of a number of DICOM servers, an SQL database and in-house developed software services to process the incoming data. A web site within the secure network allows the user to manage their submitted data. Results: The RT plan database has been developed in Microsoft .NET and users are able to send DICOM data between RT centers in Denmark. Dose-volume histogram (DVH) calculations performed by the system are comparable to those of conventional RT software. A permission system was implemented to ensure access control and easy, yet secure, data sharing across centers. The reports contain DVH statistics for structures in user defined patient groups. The system currently contains over 2200 patients in 14 collaborations. Conclusions: A central RT plan repository for use in multi-center trials and quality assurance was created. The system provides an attractive alternative to dummy runs by enabling continuous monitoring of protocol conformity and plan metrics in a trial.

  13. Planning evaluation of radiotherapy for complex lung cancer cases using helical tomotherapy

    NASA Astrophysics Data System (ADS)

    Kron, Tomas; Grigorov, Grigor; Yu, Edward; Yartsev, Slav; Chen, Jeff Z.; Wong, Eugene; Rodrigues, George; Trenka, Kris; Coad, Terry; Bauman, Glenn; Van Dyk, Jake

    2004-08-01

    Lung cancer treatment is one of the most challenging fields in radiotherapy. The aim of the present study was to investigate what role helical tomotherapy (HT), a novel approach to the delivery of highly conformal dose distributions using intensity-modulated radiation fan beams, can play in difficult cases with large target volumes typical for many of these patients. Tomotherapy plans were developed for 15 patients with stage III inoperable non-small-cell lung cancer. While not necessarily clinically indicated, elective nodal irradiation was included for all cases to create the most challenging scenarios with large target volumes. A 2 cm margin was used around the gross tumour volume (GTV) to generate primary planning target volume (PTV2) and 1 cm margin around elective nodes for secondary planning target volume (PTV1) resulting in PTV1 volumes larger than 1000 cm3 in 13 of the 15 patients. Tomotherapy plans were created using an inverse treatment planning system (TomoTherapy Inc.) based on superposition/convolution dose calculation for a fan beam thickness of 25 mm and a pitch factor between 0.3 and 0.8. For comparison, plans were created using an intensity-modulated radiation therapy (IMRT) approach planned on a commercial treatment planning system (TheraplanPlus, Nucletron). Tomotherapy delivery times for the large target volumes were estimated to be between 4 and 19 min. Using a prescribed dose of 60 Gy to PTV2 and 46 Gy to PTV1, the mean lung dose was 23.8 ± 4.6 Gy. A 'dose quality factor' was introduced to correlate the plan outcome with patient specific parameters. A good correlation was found between the quality of the HT plans and the IMRT plans with HT being slightly better in most cases. The overlap between lung and PTV was found to be a good indicator of plan quality for HT. The mean lung dose was found to increase by approximately 0.9 Gy per percent overlap volume. Helical tomotherapy planning resulted in highly conformal dose distributions. It

  14. Long-Term Results of Conformal Radiotherapy for Progressive Airway Amyloidosis

    SciTech Connect

    Truong, Minh Tam; Kachnic, Lisa A.; Grillone, Gregory A.; Bohrs, Harry K.; Lee, Richard; Sakai, Osamu; Berk, John L.

    2012-06-01

    Purpose: To evaluate the efficacy of conformal external beam radiotherapy (RT) for local control of progressive airway amyloidosis. Methods and Materials: We conducted a retrospective review of patients with biopsy-proven progressive airway amyloidosis treated with conformal RT between 2000 and 2006 at Boston Medical Center. The patients were evaluated for performance status and pulmonary function, with computed tomography and endoscopy after RT compared with the pretreatment studies. Local control was defined as the lack of progression of airway wall thickening on computed tomography imaging and stable endobronchial deposits by endoscopy. Results: A total of 10 symptomatic airway amyloidosis patients (3 laryngeal and 7 tracheobronchial) received RT to a median total dose of 20 Gy in 10 fractions within 2 weeks. At a median follow-up of 6.7 years (range, 1.5-10.3), 8 of the 10 patients had local control. The remaining 2 patients underwent repeat RT 6 and 8.4 months after initial RT, 1 for persistent bronchial obstruction and 1 for progression of subglottic amyloid disease with subsequent disease control. The Eastern Cooperative Oncology Group performance status improved at a median of 18 months after RT compared with the baseline values, from a median score of 2 to a median of 1 (p = .035). Airflow (forced expiratory volume in 1 second) measurements increased compared with the baseline values at each follow-up evaluation, reaching a 10.7% increase (p = .087) at the last testing (median duration, 64.8 months). Acute toxicity was limited to Grade 1-2 esophagitis, occurring in 40% of patients. No late toxicity was observed. Conclusions: RT prevented progressive amyloid deposition in 8 of 10 patients, resulting in a marginally increased forced expiratory volume in 1 second, and improved functional capacity, without late morbidity.

  15. Changes in Pulmonary Function After Three-Dimensional Conformal Radiotherapy, Intensity-Modulated Radiotherapy, or Proton Beam Therapy for Non-Small-Cell Lung Cancer

    SciTech Connect

    Lopez Guerra, Jose L.; Gomez, Daniel R.; Zhuang Yan; Levy, Lawrence B.; Eapen, George; Liu, Hongmei; Mohan, Radhe; Komaki, Ritsuko; Cox, James D.; Liao Zhongxing

    2012-07-15

    Purpose: To investigate the extent of change in pulmonary function over time after definitive radiotherapy for non-small-cell lung cancer (NSCLC) with modern techniques and to identify predictors of changes in pulmonary function according to patient, tumor, and treatment characteristics. Patients and Methods: We analyzed 250 patients who had received {>=}60 Gy radio(chemo)therapy for primary NSCLC in 1998-2010 and had undergone pulmonary function tests before and within 1 year after treatment. Ninety-three patients were treated with three-dimensional conformal radiotherapy, 97 with intensity-modulated radiotherapy, and 60 with proton beam therapy. Postradiation pulmonary function test values were evaluated among individual patients compared with the same patient's preradiation value at the following time intervals: 0-4 (T1), 5-8 (T2), and 9-12 (T3) months. Results: Lung diffusing capacity for carbon monoxide (DLCO) was reduced in the majority of patients along the three time periods after radiation, whereas the forced expiratory volume in 1 s per unit of vital capacity (FEV1/VC) showed an increase and decrease after radiation in a similar percentage of patients. There were baseline differences (stage, radiotherapy dose, concurrent chemotherapy) among the radiation technology groups. On multivariate analysis, the following features were associated with larger posttreatment declines in DLCO: pretreatment DLCO, gross tumor volume, lung and heart dosimetric data, and total radiation dose. Only pretreatment DLCO was associated with larger posttreatment declines in FEV1/VC. Conclusions: Lung diffusing capacity for carbon monoxide is reduced in the majority of patients after radiotherapy with modern techniques. Multiple factors, including gross tumor volume, preradiation lung function, and dosimetric parameters, are associated with the DLCO decline. Prospective studies are needed to better understand whether new radiation technology, such as proton beam therapy or

  16. Volumetric Modulated Arc Therapy for Spine Radiosurgery: Superior Treatment Planning and Delivery Compared to Static Beam Intensity Modulated Radiotherapy

    PubMed Central

    Zach, Leor; Tsvang, Lev; Alezra, Dror; Ben Ayun, Maoz

    2016-01-01

    Purpose. Spine stereotactic radiosurgery (SRS) delivers an accurate and efficient high radiation dose to vertebral metastases in 1–5 fractions. We aimed to compare volumetric modulated arc therapy (VMAT) to static beam intensity modulated radiotherapy (IMRT) for spine SRS. Methods and Materials. Ten spine lesions of previously treated SRS patients were planned retrospectively using both IMRT and VMAT with a prescribed dose of 16 Gy to 100% of the planning target volume (PTV). The plans were compared for conformity, homogeneity, treatment delivery time, and safety (spinal cord dose). Results. All evaluated parameters favored the VMAT plan over the IMRT plans. Dmin in the IMRT was significantly lower than in the VMAT plan (7.65 Gy/10.88 Gy, p < 0.001), the Dice Similarity Coefficient (DSC) was found to be significantly better for the VMAT plans compared to the IMRT plans (0.77/0.58, resp., p  value < 0.01), and an almost 50% reduction in the net treatment time was calculated for the VMAT compared to the IMRT plans (6.73 min/12.96 min, p < 0.001). Conclusions. In our report, VMAT provides better conformity, homogeneity, and safety profile. The shorter treatment time is a major advantage and not only provides convenience to the painful patient but also contributes to the precision of this high dose radiation therapy. PMID:26885513

  17. Impact of Body Mass Index on Outcomes After Conformal Radiotherapy in Patients With Prostate Cancer

    SciTech Connect

    Geinitz, Hans; Thamm, Reinhard; Mueller, Tobias; Jess, Kerstin; Zimmermann, Frank B.; Molls, Michael; Nieder, Carsten

    2011-09-01

    Purpose: Several retrospective analyses have suggested that obese men with prostate cancer treated with external beam radiotherapy (EBRT) have outcomes inferior to those of normal-weight men. However, a recently presented analysis for the first time challenged this association between body mass index (BMI) and treatment failure. It is therefore important to provide further data on this issue. Methods and Materials: This was a retrospective analysis of 564 men treated with risk-adapted conformal EBRT at a single institution. Low-risk patients received EBRT alone, and the other patients received EBRT plus endocrine treatment. In addition, high-risk patients were treated to higher EBRT doses (74 Gy). A rectal balloon catheter for internal immobilization, which can be identified on portal images, was used in 261 patients (46%). Thus, localization did not rely on bony landmarks alone in these cases. Results: The median BMI was 26, and 15% of patients had BMI {>=}30. Neither univariate nor multivariate analyses detected any significant impact of BMI on biochemical relapse, prostate cancer-specific survival, or overall survival. The 5-year biochemical relapse rate was 21% and prostate cancerspecific survival 96%. Conclusions: The present analysis of a large cohort of consecutively treated patients suggests that efforts to reduce prostate movement and geographic miss might result in comparable outcomes in obese and normal-weight patients.

  18. Longitudinal Study of Intestinal Symptoms and Fecal Continence in Patients With Conformal Radiotherapy for Prostate Cancer

    SciTech Connect

    Geinitz, Hans; Thamm, Reinhard; Keller, Monika; Astner, Sabrina T.; Heinrich, Christine; Scholz, Christian; Pehl, Christian; Kerndl, Simone; Prause, Nina; Busch, Raymonde; Molls, Michael; Zimmermann, Frank B.

    2011-04-01

    Purpose: To prospectively assess the intestinal symptoms and fecal continence in patients who had undergone conformal radiotherapy (CRT) for prostate cancer. Methods and Materials: A total of 78 men who had undergone definitive CRT for prostate cancer were evaluated. The patients were assessed before, during (treatment Weeks 4 and 6), and 2, 12, and 24 months after CRT completion. The intestinal symptoms and fecal continence were evaluated with comprehensive standardized questionnaires. Results: The intestinal symptoms were mostly intermittent, with only a small minority of patients affected daily. Defecation pain, fecal urge, and rectal mucous discharge increased significantly during therapy. Defecation pain and rectal mucous discharge had returned to baseline levels within 8 weeks and 1 year after CRT, respectively. However, fecal urge remained significantly elevated for {<=}1 year and then returned toward the pretreatment values. The prevalence of rectal bleeding was significantly elevated 2 years after CRT. Fecal continence deteriorated during CRT and remained impaired at 1 year after treatment. Incontinence was mostly minor, occurring less than once per week and predominantly affecting incontinence for gas. Conclusion: Intestinal symptoms and fecal incontinence increased during prostate CRT. Except for rectal bleeding, the intestinal symptoms, including fecal incontinence, returned to baseline levels within 1-2 years after CRT. Thus, the rate of long-term late radiation-related intestinal toxicity was low.

  19. Usefulness of image morphing techniques in cancer treatment by conformal radiotherapy

    NASA Astrophysics Data System (ADS)

    Atoui, Hussein; Sarrut, David; Miguet, Serge

    2004-05-01

    Conformal radiotherapy is a cancer treatment technique, that targets high-energy X-rays to tumors with minimal exposure to surrounding healthy tissues. Irradiation ballistics is calculated based on an initial 3D Computerized Tomography (CT) scan. At every treatment session, the random positioning of the patient, compared to the reference position defined by the initial 3D CT scan, can generate treatment inaccuracies. Positioning errors potentially predispose to dangerous exposure to healthy tissues as well as insufficient irradiation to the tumor. A proposed solution would be the use of portal images generated by Electronic Portal Imaging Devices (EPID). Portal images (PI) allow a comparison with reference images retained by physicians, namely Digitally Reconstructed Radiographs (DRRs). At present, physicians must estimate patient positional errors by visual inspection. However, this may be inaccurate and consumes time. The automation of this task has been the subject of many researches. Unfortunately, the intensive use of DRRs and the high computing time required have prevented real time implementation. We are currently investigating a new method for DRR generation that calculates intermediate DRRs by 2D deformation of previously computed DRRs. We approach this investigation with the use of a morphing-based technique named mesh warping.

  20. Three-dimensional conformal radiotherapy in the treatment of prostate cancer in Australia and New Zealand: Report on a survey of radiotherapy centres and the proceedings of a consensus workshop.

    PubMed

    Tai, K-H; Duchesne, G; Turner, S; Kneebone, A; See, A; Gogna, K; Berry, M

    2004-12-01

    There is an increasing use of 3-D conformal radiotherapy (3DCRT) in the radiotherapeutic management of prostate cancer. The Faculty of Radiation Oncology Genito-Urinary Group carried out a survey of Australian and New Zealand radiotherapy centres in the preparation of a consensus workshop. Of the 19 centres that were represented, there were 24 radiation oncologists, 16 radiation therapists and 12 medical physicists. The survey collected demographic information and data on the practices undertaken at those centres when delivering curative radiotherapy in the treatment of prostate cancer. There was much variation in the delivery of treatment in the areas of patient set-up, contouring of target volumes and organs of interest during computer planning, the techniques and the dose constraints used in these techniques, the use of adjuvant androgen deprivation therapy and the quality assurance processes used in monitoring effects of treatment. This variability reflects the range of data in the published literature. Emerging trends of practices were also identified. This is a first report on a multi-disciplinary approach to the development of guidelines in 3DCRT of prostate cancer. PMID:15601331

  1. Volumetric-modulated arc therapy in postprostatectomy radiotherapy patients: A planning comparison study

    SciTech Connect

    Forde, Elizabeth; Kneebone, Andrew; Bromley, Regina; Guo, Linxin; Hunt, Peter; Eade, Thomas

    2013-10-01

    The purpose of this study was to compare postprostatectomy planning for volumetric-modulated arc therapy (VMAT) with both single arc (SA) and double arcs (DA) against dynamic sliding window intensity-modulated radiotherapy (IMRT). Ten cases were planned with IMRT, SA VMAT, and DA VMAT. All cases were planned to achieve a minimum dose of 68 Gy to 95% of the planning target volume (PTV) and goals to limit rectal volume >40 Gy to 35% and >65 Gy to 17%, and bladder volumes >40 Gy to 50% and >65 Gy to 25%. Plans were averaged across the 10 patients and compared for mean dose, conformity, homogeneity, rectal and bladder doses, and monitor units. The mean dose to the clinical target volume and PTV was significantly higher (p<0.05) for SA compared with DA or IMRT. The homogeneity index was not significantly different: SA = 0.09; DA = 0.08; and IMRT = 0.07. The rectal V40 was lowest for the DA plan. The rectal V20 was significantly lower (p<0.05) for both the VMAT plans compared with IMRT. There were no significant differences for bladder V40 or rectal and bladder V65. The IMRT plans required 1400 MU compared with 745 for DA and 708 for SA. This study shows that for equivalent dose coverage, SA and DA VMAT plans result in higher mean doses to the clinical target volume and PTV. This greater dose heterogeneity is balanced by improved low-range rectal doses and halving of the monitor units.

  2. SU-E-T-63: Carotid Sparing Tomohelical Three Dimensional Conformal Radiotherapy for T1N0 Glottic Cancer

    SciTech Connect

    Hong, C; Ju, S; Ahn, Y; Oh, D; Noh, J; Chung, K; Kim, J; Han, Y; Choi, D

    2014-06-01

    Purpose: We investigated the dosimetric benefit and treatment efficiency of carotid-sparing TomoHelical (TH) three-dimensional conformal radiotherapy (3DCRT) for early glottic cancer. Methods: Computed tomography (CT) simulation was performed for 10 patients with early-stage (T1N0M0) glottic squamous cell carcinoma. The clinical target volume, planning target volume (PTV), carotid artery (CA), and spinal cord (SP) were delineated for each CT data set. Two-field 3DCRT (2F-3DCRT), three-field intensity-modulated radiation therapy (IMRT) (3F-IMRT), TomoHelical-IMRT (TH-IMRT), and TH-3DCRT plans were generated, with a total prescribed dose of 67.5 Gy in 30 fractions to the PTV for each patient. In order to evaluate plan quality, dosimetric characteristics were compared in terms of the conformity index (CI) and homogeneity index (HI) for the PTV, V35, V50, and V63 for the CAs and in terms of the maximum dose for the SP. Additionally, treatment planning and delivery times were compared to evaluate treatment efficiency. Results: The CIs for 3F-IMRT (0.650±0.05), TH-IMRT (0.643±0.03), and TH-3DCRT (0.631±0.03) were much better than that for 2F-3DCRT (0.318±0.03). The HIs for TH-IMRT (1.053±0.01) and TH-3DCRT (1.055±0.01) were slightly better than those for 2F-3DCRT (1.062±0.01) and 3F-IMRT (1.091±0.007). 2F-3DCRT showed poor CA sparing in terms of the V35, V50, and V63 compared to 3F-IMRT, TH-IMRT, and TH-3DCRT (p<0.05), whereas there was no significant dose difference between 3F-IMRT, TH-IMRT, and TH-3DCRT (p>0.05). The maximum dose to the SP with all plans was below 45 Gy. The treatment planning times for 2F-3DCRT (5.9±0.66 min) and TH-3DCRT (7.32±0.94 min) were much lower than those for 3F-IMRT (45.51±2.76 min) and TH-IMRT (35.58±4.41 min), whereas the delivery times with all plans was below 3 minutes. Conclusion: TH-3DCRT showed excellent carotid sparing capability, comparable to that with TH-IMRT, with high treatment efficiency and short planning and

  3. Is intensity-modulated radiotherapy better than conventional radiation treatment and three-dimensional conformal radiotherapy for mediastinal masses in patients with Hodgkin's disease, and is there a role for beam orientation optimization and dose constraints assigned to virtual volumes?

    SciTech Connect

    Girinsky, Theodore . E-mail: girinsky@igr.fr; Pichenot, Charlotte; Beaudre, Anne; Ghalibafian, Mithra; Lefkopoulos, Dimitri

    2006-01-01

    Purpose: To evaluate the role of beam orientation optimization and the role of virtual volumes (VVs) aimed at protecting adjacent organs at risk (OARs), and to compare various intensity-modulated radiotherapy (IMRT) setups with conventional treatment with anterior and posterior fields and three-dimensional conformal radiotherapy (3D-CRT). Methods and Materials: Patients with mediastinal masses in Hodgkin's disease were treated with combined modality therapy (three to six cycles of adriamycin, bleomycin, vinblastine, and dacarbazine [ABVD] before radiation treatment). Contouring and treatment planning were performed with Somavision and CadPlan Helios (Varian Systems, Palo Alto, CA). The gross tumor volume was determined according to the prechemotherapy length and the postchemotherapy width of the mediastinal tumor mass. A 10-mm isotropic margin was added for the planning target volume (PTV). Because dose constraints assigned to OARs led to unsatisfactory PTV coverage, VVs were designed for each patient to protect adjacent OARs. The prescribed dose was 40 Gy to the PTV, delivered according to guidelines from International Commission on Radiation Units and Measurements Report No. 50. Five different IMRT treatment plans were compared with conventional treatment and 3D-CRT. Results: Beam orientation was important with respect to the amount of irradiated normal tissues. The best compromise in terms of PTV coverage and protection of normal tissues was obtained with five equally spaced beams (5FEQ IMRT plan) using dose constraints assigned to VVs. When IMRT treatment plans were compared with conventional treatment and 3D-CRT, dose conformation with IMRT was significantly better, with greater protection of the heart, coronary arteries, esophagus, and spinal cord. The lungs and breasts in women received a slightly higher radiation dose with IMRT compared with conventional treatments. The greater volume of normal tissue receiving low radiation doses could be a cause for

  4. Radiobiologic comparison of helical tomotherapy, intensity modulated radiotherapy, and conformal radiotherapy in treating lung cancer accounting for secondary malignancy risks

    SciTech Connect

    Komisopoulos, Georgios; Mavroidis, Panayiotis; Rodriguez, Salvador; Stathakis, Sotirios; Papanikolaou, Nikos; Nikiforidis, Georgios C.; Sakellaropoulos, Georgios C.

    2014-01-01

    The aim of the present study is to examine the importance of using measures to predict the risk of inducing secondary malignancies in association with the clinical effectiveness of treatment plans in terms of tumor control and normal tissue complication probabilities. This is achieved by using radiobiologic parameters and measures, which may provide a closer association between clinical outcome and treatment delivery. Overall, 4 patients having been treated for lung cancer were examined. For each of them, 3 treatment plans were developed based on the helical tomotherapy (HT), multileaf collimator-based intensity modulated radiation therapy (IMRT), and 3-dimensional conformal radiation therapy (CRT) modalities. The different plans were evaluated using the complication-free tumor control probability (p{sub +}), the overall probability of injury (p{sub I}), the overall probability of control/benefit (p{sub B}), and the biologically effective uniform dose (D{sup ¯¯}). These radiobiologic measures were used to develop dose-response curves (p-D{sup ¯¯} diagram), which can help to evaluate different treatment plans when used in conjunction with standard dosimetric criteria. The risks for secondary malignancies in the heart and the contralateral lung were calculated for the 3 radiation modalities based on the corresponding dose-volume histograms (DVHs) of each patient. Regarding the overall evaluation of the different radiation modalities based on the p{sub +} index, the average values of the HT, IMRT, and CRT are 67.3%, 61.2%, and 68.2%, respectively. The corresponding average values of p{sub B} are 75.6%, 70.5%, and 71.0%, respectively, whereas the average values of p{sub I} are 8.3%, 9.3%, and 2.8%, respectively. Among the organs at risk (OARs), lungs show the highest probabilities for complications, which are 7.1%, 8.0%, and 1.3% for the HT, IMRT, and CRT modalities, respectively. Similarly, the biologically effective prescription doses (D{sub B}{sup ¯¯}) for the

  5. Routine EPID in-vivo dosimetry in a reference point for conformal radiotherapy treatments

    NASA Astrophysics Data System (ADS)

    Fidanzio, Andrea; Azario, Luigi; Greco, Francesca; Cilla, Savino; Piermattei, Angelo

    2015-04-01

    In-vivo dosimetry (IVD) in external beam radiotherapy is used to detect major clinically relevant differences between planned and delivered dose. Moreover, a detailed analysis of its results, when routinely reported and discussed by the radiotherapy staff, can limit the likelihood of error transmission to many treatments. A first experience of routine EPID-based IVD in a reference point has been performed in our department for 3D-CRT treatments over a three-year period. More than 14 000 images were acquired and 1287 treatment plans were verified. The IVD checks were obtained three times in the first week and then weekly. Tolerance levels of ±5% for pelvic-abdomen, head-neck and breast irradiations and ±6% for lung treatments were adopted for the in-vivo measured dose per fraction. A statistical analysis of the IVD results was performed grouping the data by: anatomical regions, treatment units, open and wedged fields and gantry angles. About 10% of the checked doses per fraction showed dosimetric discrepancies out of the tolerance levels. The causes of the discrepancies were 70% delivery or planning errors, 20% morphological changes and 10% procedural limitations. 41 cases (3.2%) have required special investigations because their in-vivo doses per fraction, averaged over the first three sessions, were out of the tolerance levels and in 19 cases (1.5%) the deviations gave rise to an intervention. Statistically significant differences of average variations between planned and delivered doses were observed for: (i) 30° wedged 10 MV fields with respect to those of other wedged or open 10 MV fields delivered by two linacs, due to the incorrect TPS implementation of that wedge transmission factor; (ii) anterior-posterior and posterior-anterior beams with respect to the other gantry orientations for one linac, due to the beam attenuation introduced by the treatment couch; (iii) lateral fields with respect to medial fields of breast irradiations for all linacs, due

  6. Prone Hypofractionated Whole-Breast Radiotherapy Without a Boost to the Tumor Bed: Comparable Toxicity of IMRT Versus a 3D Conformal Technique

    SciTech Connect

    Hardee, Matthew E.; Raza, Shahzad; Becker, Stewart J.; Jozsef, Gabor; Lymberis, Stella C.; Hochman, Tsivia; Goldberg, Judith D.; DeWyngaert, Keith J.; Formenti, Silvia C.

    2012-03-01

    Purpose: We report a comparison of the dosimetry and toxicity of three-dimensional conformal radiotherapy (3D-CRT) vs. intensity-modulated radiotherapy (IMRT) among patients treated in the prone position with the same fractionation and target of the hypofractionation arm of the Canadian/Whelan trial. Methods and Materials: An institutional review board-approved protocol identified a consecutive series of early-stage breast cancer patients treated according to the Canadian hypofractionation regimen but in the prone position. Patients underwent IMRT treatment planning and treatment if the insurance carrier approved reimbursement for IMRT; in case of refusal, a 3D-CRT plan was used. A comparison of the dosimetric and toxicity outcomes during the acute, subacute, and long-term follow-up of the two treatment groups is reported. Results: We included 97 consecutive patients with 100 treatment plans in this study (3 patients with bilateral breast cancer); 40 patients were treated with 3D-CRT and 57 with IMRT. IMRT significantly reduced the maximum dose (Dmax median, 109.96% for 3D-CRT vs. 107.28% for IMRT; p < 0.0001, Wilcoxon test) and improved median dose homogeneity (median, 1.15 for 3D-CRT vs. 1.05 for IMRT; p < 0.0001, Wilcoxon test) when compared with 3D-CRT. Acute toxicity consisted primarily of Grade 1 to 2 dermatitis and occurred in 92% of patients. Grade 2 dermatitis occurred in 13% of patients in the 3D-CRT group and 2% in the IMRT group. IMRT moderately decreased rates of acute pruritus (p = 0.03, chi-square test) and Grade 2 to 3 subacute hyperpigmentation (p = 0.01, Fisher exact test). With a minimum of 6 months' follow-up, the treatment was similarly well tolerated in either group, including among women with large breast volumes. Conclusion: Hypofractionated breast radiotherapy is well tolerated when treating patients in the prone position, even among those with large breast volumes. Breast IMRT significantly improves dosimetry but yields only a modest but

  7. Development of Advanced Multi-Modality Radiation Treatment Planning Software for Neutron Radiotherapy and Beyond

    SciTech Connect

    Nigg, D; Wessol, D; Wemple, C; Harkin, G; Hartmann-Siantar, C

    2002-08-20

    The Idaho National Engineering and Environmental Laboratory (INEEL) has long been active in development of advanced Monte-Carlo based computational dosimetry and treatment planning methods and software for advanced radiotherapy, with a particular focus on Neutron Capture Therapy (NCT) and, to a somewhat lesser extent, Fast-Neutron Therapy. The most recent INEEL software system of this type is known as SERA, Simulation Environment for Radiotherapy Applications. As a logical next step in the development of modern radiotherapy planning tools to support the most advanced research, INEEL and Lawrence Livermore National Laboratory (LLNL), the developers of the PEREGRTNE computational engine for radiotherapy treatment planning applications, have recently launched a new project to collaborate in the development of a ''next-generation'' multi-modality treatment planning software system that will be useful for all modern forms of radiotherapy.

  8. American Association of Physicists in Medicine Radiation Therapy Committee Task Group 53: quality assurance for clinical radiotherapy treatment planning.

    PubMed

    Fraass, B; Doppke, K; Hunt, M; Kutcher, G; Starkschall, G; Stern, R; Van Dyke, J

    1998-10-01

    In recent years, the sophistication and complexity of clinical treatment planning and treatment planning systems has increased significantly, particularly including three-dimensional (3D) treatment planning systems, and the use of conformal treatment planning and delivery techniques. This has led to the need for a comprehensive set of quality assurance (QA) guidelines that can be applied to clinical treatment planning. This document is the report of Task Group 53 of the Radiation Therapy Committee of the American Association of Physicists in Medicine. The purpose of this report is to guide and assist the clinical medical physicist in developing and implementing a comprehensive but viable program of quality assurance for modern radiotherapy treatment planning. The scope of the QA needs for treatment planning is quite broad, encompassing image-based definition of patient anatomy, 3D beam descriptions for complex beams including multileaf collimator apertures, 3D dose calculation algorithms, and complex plan evaluation tools including dose volume histograms. The Task Group recommends an organizational framework for the task of creating a QA program which is individualized to the needs of each institution and addresses the issues of acceptance testing, commissioning the planning system and planning process, routine quality assurance, and ongoing QA of the planning process. This report, while not prescribing specific QA tests, provides the framework and guidance to allow radiation oncology physicists to design comprehensive and practical treatment planning QA programs for their clinics. PMID:9800687

  9. Radiotherapy.

    PubMed

    Adamietz, Irenaus A

    2010-01-01

    The intrathoracic growth of the tumor causes several severe symptoms as cough, dyspnea, chest pain, hemoptysis, hoarseness, anorexia/nausea, and dysphagia. In patients with manifest or threatening symptoms radiotherapy (RT) as an effective measure should be implemented into the management concept. Palliative RT radiotherapy prefers short hypofractionated schemas (e.g. 10 x 3 Gy, 4 x 5 Gy, 2 x 8 Gy, 1 x 10 Gy). Careful radiation planning supports the precision of palliative RT and reduces significantly the complication rate. A good response and prolonged palliation effects (6-12 months) can be achieved in many cases. However, the minimum biologically equivalent dose should not be less than 35 Gy. RT produces a good outcome in all types of metastases of lung carcinoma. In emergencies like VCSS or spinal cord compression RT should be initiated immediately. The selection of the optimal therapy for locally advanced lung carcinoma with malignant airway obstruction is difficult. Both brachytherapy and percutaneous irradiation are effective, however published results including local a sum of response, functionality and life quality demonstrates more benefit by percutaneous RT. Due to different physical properties of these two methods the combination of brachytherapy and external beam irradiation may be advantageous. PMID:19955803

  10. OUTCOMES AFTER INTENSITY-MODULATED VERSUS CONFORMAL RADIOTHERAPY IN OLDER MEN WITH NONMETASTATIC PROSTATE CANCER

    PubMed Central

    Bekelman, Justin E.; Mitra, Nandita; Efstathiou, Jason; Liao, Kaijun; Sunderland, Robert; Yeboa, Deborah N.; Armstrong, Katrina

    2013-01-01

    Purpose There is little evidence comparing complications after intensity-modulated (IMRT) vs. three-dimensional conformal radiotherapy (CRT) for prostate cancer. The study objective was to test the hypothesis that IMRT, compared with CRT, is associated with a reduction in bowel, urinary, and erectile complications in elderly men with nonmetastatic prostate cancer. Methods and Materials We undertook an observational cohort study using registry and administrative claims data from the SEER-Medicare database. We identified men aged 65 years or older diagnosed with nonmetastatic prostate cancer in the United States between 2002 and 2004 who received IMRT (n = 5,845) or CRT (n = 6,753). The primary outcome was a composite measure of bowel complications. Secondary outcomes were composite measures of urinary and erectile complications. We also examined specific subsets of bowel (proctitis/hemorrhage) and urinary (cystitis/hematuria) events within the composite complication measures. Results IMRT was associated with reductions in composite bowel complications (24-month cumulative incidence 18.8% vs. 22.5%; hazard ratio [HR] 0.86; 95% confidence interval [CI], 0.79–0.93) and proctitis/hemorrhage (HR 0.78; 95% CI, 0.64–0.95). IMRT was not associated with rates of composite urinary complications (HR 0.93; 95% CI, 0.83–1.04) or cystitis/hematuria (HR 0.94; 95% CI, 0.83–1.07). The incidence of erectile complications involving invasive procedures was low and did not differ significantly between groups, although IMRT was associated with an increase in new diagnoses of impotence (HR 1.27, 95% CI, 1.14–1.42). Conclusion IMRT is associated with a small reduction in composite bowel complications and proctitis/hemorrhage compared with CRT in elderly men with nonmetastatic prostate cancer. PMID:21498008

  11. Combined Effects of Embolization and Hypofractionated Conformal Stereotactic Radiotherapy in Arteriovenous Malformations of the Brain

    PubMed Central

    Lindvall, P.; Wikholm, G.; Bergström, P.; Löfroth, P.; Bergenheim, A.T.

    2005-01-01

    Summary There are three major treatment options for cerebral AVMs; surgery, embolization and radiosurgery. Embolization may be effective to reduce the size and density but completely obliterates AVMs only in a minority of cases. Radiosurgery may be an alternative to resection, especially in smaller AVMs. Large AVMs have been considered difficult to treat safely and effectively with single fraction radiosurgery. Hypofractionated conformal stereotactic radiotherapy (HCSRT) alone or in combination with embolization may be an alternative treatment. Embolization may reduce the volume and density of AVMs, followed by HCSRT, allowing a safe delivery of a higher total dose of radiation than possible with a single fraction. Sixteen patients with AVMs were treated with embolization and HCSRT. Embolization was performed in 1-6 (median 2) sessions. HCSRT was delivered in 5 fractions with 6-7 Gy each to the total dose of 30-35 Gy. Cerebral angiographies before and after embolization were digitally compared for calculation of volume reduction and luminescence as a measure of AVM density. The mean AVM volume in 15 patients was reduced from 11.9 ± 2.1 (1-29, median 10.0) ml to 6.5 ± 2.0 (0.5-28, median 3) ml by embolization. The luminescence for all AVMs was significantly higher after than before embolization, indicating that all AVMs were less dense after embolization. Thirteen out of 16 patients (13/16, 81%) treated with embolization and HCSRT have so far shown obliteration of their AVMs 2-9 (median 4) years after HCSRT. Three patients experienced neurological sequele after embolization, and three patients developed radionecrosis after HCSRT. Using a new method to compare cerebral angiographies in AVMs we report reduction in density and volume after embolization. The obliteration rate of a combined treatment with embolization and HCSRT seems comparable with single fraction radiosurgery although the AVMs in our series are larger than reported in most series treated with single

  12. Outcomes After Intensity-Modulated Versus Conformal Radiotherapy in Older Men With Nonmetastatic Prostate Cancer

    SciTech Connect

    Bekelman, Justin E.; Mitra, Nandita; Efstathiou, Jason; Liao Kaijun; Sunderland, Robert; Yeboa, Deborah N.; Armstrong, Katrina

    2011-11-15

    Purpose: There is little evidence comparing complications after intensity-modulated (IMRT) vs. three-dimensional conformal radiotherapy (CRT) for prostate cancer. The study objective was to test the hypothesis that IMRT, compared with CRT, is associated with a reduction in bowel, urinary, and erectile complications in elderly men with nonmetastatic prostate cancer. Methods and Materials: We undertook an observational cohort study using registry and administrative claims data from the SEER-Medicare database. We identified men aged 65 years or older diagnosed with nonmetastatic prostate cancer in the United States between 2002 and 2004 who received IMRT (n = 5,845) or CRT (n = 6,753). The primary outcome was a composite measure of bowel complications. Secondary outcomes were composite measures of urinary and erectile complications. We also examined specific subsets of bowel (proctitis/hemorrhage) and urinary (cystitis/hematuria) events within the composite complication measures. Results: IMRT was associated with reductions in composite bowel complications (24-month cumulative incidence 18.8% vs. 22.5%; hazard ratio [HR] 0.86; 95% confidence interval [CI], 0.79-0.93) and proctitis/hemorrhage (HR 0.78; 95% CI, 0.64-0.95). IMRT was not associated with rates of composite urinary complications (HR 0.93; 95% CI, 0.83-1.04) or cystitis/hematuria (HR 0.94; 95% CI, 0.83-1.07). The incidence of erectile complications involving invasive procedures was low and did not differ significantly between groups, although IMRT was associated with an increase in new diagnoses of impotence (HR 1.27, 95% CI, 1.14-1.42). Conclusion: IMRT is associated with a small reduction in composite bowel complications and proctitis/hemorrhage compared with CRT in elderly men with nonmetastatic prostate cancer.

  13. Correlation Between Acute and Late Toxicity in 973 Prostate Cancer Patients Treated With Three-Dimensional Conformal External Beam Radiotherapy

    SciTech Connect

    Jereczek-Fossa, Barbara A.; Zerini, Dario; Fodor, Cristiana

    2010-09-01

    Purpose: To analyze the correlation between acute and late injury in 973 prostate cancer patients treated with radiotherapy and to evaluate the effect of patient-, tumor-, and treatment-related variables on toxicity. Methods and Materials: Of the 973 patients, 542 and 431 received definitive or postprostatectomy radiotherapy, respectively. Three-dimensional conformal radiotherapy included a six-field technique and two-dynamic arc therapy. Toxicity was classified according to the Radiation Therapy Oncology Group/European Organization for Research and Treatment of Cancer criteria. The correlation between acute and late toxicity (incidence and severity) was assessed. Results: Multivariate analysis showed that age {<=}65 years (p = .06) and use of the three-dimensional, six-field technique (p <.0001) correlated significantly with greater acute rectal toxicity. The three-dimensional, six-field technique (p = .0002), dose >70 Gy (p = .014), and radiotherapy duration (p = .05) correlated with greater acute urinary toxicity. Acute rectal toxicity (p <.0001) was the only factor that correlated with late rectal injury on multivariate analysis. Late urinary toxicity correlated with acute urinary events (p <.0001) and was inversely related to the use of salvage radiotherapy (p = .018). A highly significant correlation was found between the incidence of acute and late events for both rectal (p <.001) and urinary (p <.001) reactions. The severity of acute toxicity (Grade 2 or greater) was predictive for the severity of late toxicity for both rectal and urinary events (p <.001). Conclusion: The results of our study have shown that the risk of acute reactions depends on both patient-related (age) and treatment-related (dose, technique) factors. Acute toxicity was an independent significant predictor of late toxicity. These findings might help to predict and prevent late radiotherapy-induced complications.

  14. Adjuvant Chemoradiation for Gastric Cancer Using Epirubicin, Cisplatin, and 5-Fluorouracil Before and After Three-Dimensional Conformal Radiotherapy With Concurrent Infusional 5-Fluorouracil: A Multicenter Study of the Trans-Tasman Radiation Oncology Group

    SciTech Connect

    Leong, Trevor; Joon, Daryl Lim; Willis, David; Jayamoham, Jayasingham; Spry, Nigel; Harvey, Jennifer; Di Iulio, Juliana; Milner, Alvin; Mann, G. Bruce; Michael, Michael

    2011-03-01

    Purpose: The INT0116 study has established postoperative chemoradiotherapy as the standard of care for completely resected gastric adenocarcinoma. However, the optimal chemoradiation regimen remains to be defined. We conducted a prospective, multicenter study to evaluate an alternative chemoradiation regimen that combines more current systemic treatment with modern techniques of radiotherapy delivery. Methods and Materials: Patients with adenocarcinoma of the stomach who had undergone an R0 resection were eligible. Adjuvant therapy consisted of one cycle of epirubicin, cisplatin, and 5-FU (ECF), followed by radiotherapy with concurrent infusional 5-FU, and then two additional cycles of ECF. Radiotherapy was delivered using precisely defined, multiple-field, three-dimensional conformal techniques. Results: A total of 54 assessable patients were enrolled from 19 institutions. The proportion of patients commencing Cycles 1, 2, and 3 of ECF chemotherapy were 100%, 81%, and 67% respectively. In all, 94% of patients who received radiotherapy completed treatment as planned. Grade 3/4 neutropenia occurred in 66% of patients with 7.4% developing febrile neutropenia. Most neutropenic episodes (83%) occurred in the post-radiotherapy period during cycles 2 and 3 of ECF. Grade 3/4 gastrointestinal toxicity occurred in 28% of patients. In all, 35% of radiotherapy treatment plans contained protocol deviations that were satisfactorily amended before commencement of treatment. At median follow-up of 36 months, the 3-year overall survival rate was estimated at 61.6%. Conclusions: This adjuvant regimen using ECF before and after three-dimensional conformal chemoradiation is feasible and can be safely delivered in a cooperative group setting. A regimen similar to this is currently being compared with the INT0116 regimen in a National Cancer Institute-sponsored, randomized Phase III trial.

  15. The adaptation of megavoltage cone beam CT for use in standard radiotherapy treatment planning

    NASA Astrophysics Data System (ADS)

    Thomas, T. Hannah Mary; Devakumar, D.; Purnima, S.; Ravindran, B. Paul

    2009-04-01

    Potential areas where megavoltage computed tomography (MVCT) could be used are second- and third-phase treatment planning in 3D conformal radiotherapy and IMRT, adaptive radiation therapy, single fraction palliative treatment and for the treatment of patients with metal prostheses. A feasibility study was done on using MV cone beam CT (CBCT) images generated by proprietary 3D reconstruction software based on the FDK algorithm for megavoltage treatment planning. The reconstructed images were converted to a DICOM file set. The pixel values of megavoltage cone beam computed tomography (MV CBCT) were rescaled to those of kV CT for use with a treatment planning system. A calibration phantom was designed and developed for verification of geometric accuracy and CT number calibration. The distance measured between two marker points on the CBCT image and the physical dimension on the phantom were in good agreement. Point dose verification for a 10 cm × 10 cm beam at a gantry angle of 0° and SAD of 100 cm were performed for a 6 MV beam for both kV and MV CBCT images. The point doses were found to vary between ±6.1% of the dose calculated from the kV CT image. The isodose curves for 6 MV for both kV CT and MV CBCT images were within 2% and 3 mm distance-to-agreement. A plan with three beams was performed on MV CBCT, simulating a treatment plan for cancer of the pituitary. The distribution obtained was compared with those corresponding to that obtained using the kV CT. This study has shown that treatment planning with MV cone beam CT images is feasible.

  16. The adaptation of megavoltage cone beam CT for use in standard radiotherapy treatment planning.

    PubMed

    Thomas, T Hannah Mary; Devakumar, D; Purnima, S; Ravindran, B Paul

    2009-04-01

    Potential areas where megavoltage computed tomography (MVCT) could be used are second- and third-phase treatment planning in 3D conformal radiotherapy and IMRT, adaptive radiation therapy, single fraction palliative treatment and for the treatment of patients with metal prostheses. A feasibility study was done on using MV cone beam CT (CBCT) images generated by proprietary 3D reconstruction software based on the FDK algorithm for megavoltage treatment planning. The reconstructed images were converted to a DICOM file set. The pixel values of megavoltage cone beam computed tomography (MV CBCT) were rescaled to those of kV CT for use with a treatment planning system. A calibration phantom was designed and developed for verification of geometric accuracy and CT number calibration. The distance measured between two marker points on the CBCT image and the physical dimension on the phantom were in good agreement. Point dose verification for a 10 cm x 10 cm beam at a gantry angle of 0 degrees and SAD of 100 cm were performed for a 6 MV beam for both kV and MV CBCT images. The point doses were found to vary between +/-6.1% of the dose calculated from the kV CT image. The isodose curves for 6 MV for both kV CT and MV CBCT images were within 2% and 3 mm distance-to-agreement. A plan with three beams was performed on MV CBCT, simulating a treatment plan for cancer of the pituitary. The distribution obtained was compared with those corresponding to that obtained using the kV CT. This study has shown that treatment planning with MV cone beam CT images is feasible. PMID:19287087

  17. Inverse planning of energy-modulated electron beams in radiotherapy

    SciTech Connect

    Gentry, John R. . E-mail: gentryj@gmh.org; Steeves, Richard; Paliwal, Bhudatt A.

    2006-01-01

    The use of megavoltage electron beams often poses a clinical challenge in that the planning target volume (PTV) is anterior to other radiosensitive structures and has variable depth. To ensure that skin as well as the deepest extent of the PTV receives the prescribed dose entails prescribing to a point beyond the depth of peak dose for a single electron energy. This causes dose inhomogeneities and heightened potential for tissue fibrosis, scarring, and possible soft tissue necrosis. Use of bolus on the skin improves the entrant dose at the cost of decreasing the therapeutic depth that can be treated. Selection of a higher energy to improve dose homogeneity results in increased dose to structures beyond the PTV, as well as enlargement of the volume receiving heightened dose. Measured electron data from a linear accelerator was used as input to create an inverse planning tool employing energy and intensity modulation using bolus (e-IMRT{sup TM}). Using tools readily available in a radiotherapy department, the applications of energy and intensity modulation on the central axis makes it possible to remove hot spots of 115% or more over the depths clinically encountered. The e-IMRT{sup TM} algorithm enables the development of patient-specific dose distributions with user-defined positions of peak dose, range, and reduced dose to points beyond the prescription point.

  18. Dosimetric Comparison Between Intensity-Modulated with Coplanar Field and 3D Conformal Radiotherapy with Noncoplanar Field for Postocular Invasion Tumor

    SciTech Connect

    Tu Wenyong; Liu Lu Zeng Jun; Yin Weidong; Li Yun

    2010-07-01

    This study presents a dosimetric optimization effort aiming to compare noncoplanar field (NCF) on 3 dimensions conformal radiotherapy (3D-CRT) and coplanar field (CF) on intensity-modulated radiotherapy (IMRT) planning for postocular invasion tumor. We performed a planning study on the computed tomography data of 8 consecutive patients with localized postocular invasion tumor. Four fields NCF 3D-CRT in the transverse plane with gantry angles of 0-10 deg., 30-45 deg., 240-270 deg., and 310-335 deg. degrees were isocentered at the center of gravity of the target volume. The geometry of the beams was determined by beam's eye view. The same constraints were prepared with between CF IMRT optimization and NCF 3D-CRT treatment. The maximum point doses (D max) for the different optic pathway structures (OPS) with NCF 3D-CRT treatment should differ in no more than 3% from those with the NCF IMRT plan. Dose-volume histograms (DVHs) were obtained for all targets and organ at risk (OAR) with both treatment techniques. Plans with NCF 3D-CRT and CF IMRT constraints on target dose in homogeneity were computed, as well as the conformity index (CI) and homogeneity index (HI) in the target volume. The PTV coverage was optimal with both NCF 3D-CRT and CF IMRT plans in the 8 tumor sites. No difference was noted between the two techniques for the average D{sub max} and D{sub min} dose. NCF 3D-CRT and CF IMRT will yield similar results on CI. However, HI was a significant difference between NCF 3D-CRT and CF IMRT plan (p < 0.001). Physical endpoints for target showed the mean target dose to be low in the CF IMRT plan, caused by a large target dose in homogeneity (p < 0.001). The impact of NCF 3D-CRT versus CF IMRT set-up is very slight. NCF3D-CRT is one of the treatment options for postocular invasion tumor. However, constraints for OARs are needed.

  19. Impact of the accuracy of automatic tumour functional volume delineation on radiotherapy treatment planning

    NASA Astrophysics Data System (ADS)

    Le Maitre, Amandine; Hatt, Mathieu; Pradier, Olivier; Cheze-le Rest, Catherine; Visvikis, Dimitris

    2012-09-01

    Over the past few years several automatic and semi-automatic PET segmentation methods for target volume definition in radiotherapy have been proposed. The objective of this study is to compare different methods in terms of dosimetry. For such a comparison, a gold standard is needed. For this purpose, realistic GATE-simulated PET images were used. Three lung cases and three H&N cases were designed with various shapes, contrasts and heterogeneities. Four different segmentation approaches were compared: fixed and adaptive thresholds, a fuzzy C-mean and the fuzzy locally adaptive Bayesian method. For each of these target volumes, an IMRT treatment plan was defined. The different algorithms and resulting plans were compared in terms of segmentation errors and ground-truth volume coverage using different metrics (V95, D95, homogeneity index and conformity index). The major differences between the threshold-based methods and automatic methods occurred in the most heterogeneous cases. Within the two groups, the major differences occurred for low contrast cases. For homogeneous cases, equivalent ground-truth volume coverage was observed for all methods but for more heterogeneous cases, significantly lower coverage was observed for threshold-based methods. Our study demonstrates that significant dosimetry errors can be avoided by using more advanced image-segmentation methods.

  20. Simulational study of a dosimetric comparison between a Gamma Knife treatment plan and an intensity-modulated radiotherapy plan for skull base tumors

    PubMed Central

    Nakazawa, Hisato; Mori, Yoshimasa; Komori, Masataka; Tsugawa, Takahiko; Shibamoto, Yuta; Kobayashi, Tatsuya; Hashizume, Chisa; Uchiyama, Yukio; Hagiwara, Masahiro

    2014-01-01

    Fractionated stereotactic radiotherapy (SRT) is performed with a linear accelerator-based system such as Novalis. Recently, Gamma Knife Perfexion (PFX) featured the Extend system with relocatable fixation devices available for SRT. In this study, the dosimetric results of these two modalities were compared from the viewpoint of conformity, heterogeneity and gradient in target covering. A total of 14 patients with skull base tumors were treated with Novalis intensity-modulated (IM)-SRT. Treatment was planned on an iPlan workstation. Five- to seven-beam IM-SRT was performed in 14–18 fractions with a fraction dose of 2.5 or 3 Gy. With these patients' data, additional treatment planning was simulated using a GammaPlan workstation for PFX-SRT. Reference CT images with planning structure contour sets on iPlan, including the planning target volume (PTV, 1.1–102.2 ml) and organs at risk, were exported to GammaPlan in DICOM-RT format. Dosimetric results for Novalis IM-SRT and PFX-SRT were evaluated in the same prescription doses. The isocenter number of PFX was between 12 and 50 at the isodose contour of 50–60%. The PTV coverage was 95–99% for Novalis and 94–98% for PFX. The conformity index (CI) was 1.11–1.61 and 1.04–1.15, the homogeneity index (HI) was 1.1–3.62 and 2.3–3.25, and the gradient index (GI) was 3.72–7.97 and 2.54–3.39 for Novalis and PFX, respectively. PTV coverage by Novalis and PFX was almost equivalent. PFX was superior in CI and GI, and Novalis was better in HI. Better conformality would be achieved by PFX, when the homogeneity inside tumors is less important. PMID:24351459

  1. SU-E-J-268: Is It Necessary to Account for Organs at Risk Respiratory Induced Motion Effects in Radiotherapy Planning with Tumor Tracking?

    SciTech Connect

    Gilles, M; Boussion, N; Visvikis, D; Fayad, H; Pradier, O

    2014-06-01

    Purpose: The objective of this study was to evaluate the necessity to account for the organs at risk (OARs) respiratory induced motion in addition to the tumor displacement when planning a radiotherapy treatment that accounts for tumor motion. Methods: For 18 lung cancer patients, conformational radiotherapy treatment plans were generated using 3 different CT volumes: the two extreme respiratory phases corresponding to either the full inspiration (plan 1) or expiration (plan 3), as well as a manually deformed phase consisting in full inspiration combined with the full expiration tumor location (plan 2) simulating a tumor tracking plan without addressing OARs motion. Treatment plans were initially created on plan 1 and then transferred to plan 2 and 3 which represent respectively the tumor displacement only and the whole anatomic variations due to breathing. The dose coverage and the dose delivered to the OARs were compared using conformational indexes and generalized equivalent uniform dose. Results: The worst conformational indexes were obtained for plans with all anatomic deformations (Table 1) with an underestimation of the 95% isodose spreading on healthy tissue compared to plans considering the tumor displacement only. Furthermore, mean doses to the OARs when accounting for all the anatomic changes were always higher than those associated with the tumor displacement only: the mean difference between these two plans was 1±1.37 Gy (maximum of 3.8 Gy) for the heart and 1.4±1.42 Gy (maximum of 4.1 Gy) for the lung in which the tumor was located (Figure 1). Conclusion: OARs deformations due to breathing motion should be included in the treatment planning in order to avoid unnecessary OARs dose and/or allow for a tumor dose escalation. This is even more important for treatments like stereotactic radiation therapy which necessitates a high precision ballistic and dose control.

  2. Proton Beam Radiotherapy Versus Three-Dimensional Conformal Stereotactic Body Radiotherapy in Primary Peripheral, Early-Stage Non-Small-Cell Lung Carcinoma: A Comparative Dosimetric Analysis

    SciTech Connect

    Macdonald, O. Kenneth; Kruse, Jon J.; Miller, Janelle M.; Garces, Yolanda I.; Brown, Paul D.; Miller, Robert C.; Foote, Robert L.

    2009-11-01

    Purpose: Proton radiotherapy (PT) and stereotactic body radiotherapy (SBRT) have the capacity to optimize the therapeutic ratio. We analyzed the dosimetric differences between PT and SBRT in treating primary peripheral early-stage non-small-cell lung cancer. Methods and Materials: Eight patients were simulated, planned, and treated with SBRT according to accepted techniques. SBRT treatments were retrospectively planned using heterogeneity corrections. PT treatment plans were generated using single-, two-, and three-field passively scattered and actively scanned proton beams. Calculated dose characteristics were compared. Results: Comparable planning target volume (PTV) median minimum and maximum doses were observed between PT and SBRT plans. Higher median maximum doses 2 cm from the PTV were observed for PT, but higher median PTV doses were observed for SBRT. The total lung mean and V5 doses were significantly lower with actively scanned PT. The lung V13 and V20 were comparable. The dose to normal tissues was lower with PT except to skin and ribs. Although the maximum doses to skin and ribs were similar or higher with PT, the median doses to these structures were higher with SBRT. Passively scattered plans, compared with actively scanned plans, typically demonstrated higher doses to the PTV, lung, and organs at risk. Conclusions: Single-, two-, or three-field passively or actively scanned proton therapy delivered comparable PTV dose with generally less dose to normal tissues in these hypothetic treatments. Actively scanned beam plans typically had more favorable dose characteristics to the target, lung, and other soft tissues compared with the passively scanned plans. The clinical significance of these findings remains to be determined.

  3. Dosimetric effect of Elekta Beam Modulator micromultileaf in three-dimensional conformal radiotherapy and intensity-modulated radiotherapy for prostate cancer

    SciTech Connect

    Carosi, Alessandra Ingrosso, Gianluca; Ponti, Elisabetta; Tolu, Barbara; Murgia, Alessandra; Cristino, Daniela di; Santoni, Riccardo

    2014-07-01

    The purpose of this study is to analyze the dosimetric effect of Elekta Beam Modulator in 3-dimensional conformal radiation therapy (3DCRT) and in intensity-modulated radiation therapy (IMRT) for localized prostate cancer. We compared treatment plans developed with 2 different Elekta multileaf collimators (MLC): Beam Modulator micro-MLC (mMLC) (4-mm leaf width at the isocenter) and standard MLC (10-mm leaf width at the isocenter). The comparison was performed for 15 patients with localized prostate cancer in 3DCRT and IMRT delivery; a total of 60 treatment plans were processed. The dose-volume histograms were used to provide the quantitative comparison between plans. In particular, we analyzed differences between rectum and bladder sparing in terms of a set of appropriate Vx (percentage of organ at risk [OAR] volume receiving the x dose) and differences between target conformity and coverage in terms of coverage factor and conformation number. Our analysis demonstrates that in 3DCRT there is an advantage in the use of Elekta Beam Modulator mMLC in terms of organ sparing; in particular, a significant decrease in rectal V{sub 60} and V{sub 50} (p = 0.001) and in bladder V{sub 70} and V{sub 65} (p = 0.007 and 0.002, respectively) was found. Moreover, a better target dose conformity was obtained (p = 0.002). IMRT plans comparison demonstrated no significant differences between the use of the 4 or 10-mm MLCs. Our analysis shows that in 3DCRT the use of the Elekta Beam Modulator mMLC gives a gain in target conformity and in OARs dose sparing whereas in IMRT plans there is no advantage.

  4. Toward automatic field selection and planning using Monte Carlo-based direct aperture optimization in modulated electron radiotherapy

    NASA Astrophysics Data System (ADS)

    Alexander, Andrew; DeBlois, François; Seuntjens, Jan

    2010-08-01

    Modulated electron radiotherapy (MERT) has been proven to produce optimal plans for shallow tumors. This study investigates automated approaches to the field determination process in generating optimal MERT plans for few-leaf electron collimator (FLEC)-based MERT, by generating a large database of pre-calculated beamlets stored as phase-space files. Beamlets can be used in an overlapping feathered pattern to reduce the effect of abutting fields, which can contribute to dose inhomogeneities within the target. Beamlet dose calculation was performed by Monte Carlo (MC) simulations prior to direct aperture optimization (DAO). The second part of the study examines a preliminary clinical comparison between FLEC-based MERT and helical TomoTherapy. A MERT plan for spinal irradiation was not able to conform to the PTV dose constraints as closely as the TomoTherapy plan, although the TomoTherapy plan was taken as is, i.e. not Monte Carlo re-calculated. Despite the remaining gradients in the PTV, the MERT plan was superior in reducing the low-dose bath typical of TomoTherapy plans. In conclusion, the FLEC-based MERT planning techniques developed within the study produced promising MERT plans with minimal user input. The phase-space database reduces the MC calculation time and the feathered field pattern improves target homogeneity. With further investigations, FLEC-based MERT will find an important niche in clinical radiation therapy.

  5. Monte Carlo Simulations for Dosimetry in Prostate Radiotherapy with Different Intravesical Volumes and Planning Target Volume Margins

    PubMed Central

    Lv, Wei; Yu, Dong; He, Hengda; Liu, Qian

    2016-01-01

    In prostate radiotherapy, the influence of bladder volume variation on the dose absorbed by the target volume and organs at risk is significant and difficult to predict. In addition, the resolution of a typical medical image is insufficient for visualizing the bladder wall, which makes it more difficult to precisely evaluate the dose to the bladder wall. This simulation study aimed to quantitatively investigate the relationship between the dose received by organs at risk and the intravesical volume in prostate radiotherapy. The high-resolution Visible Chinese Human phantom and the finite element method were used to construct 10 pelvic models with specific intravesical volumes ranging from 100 ml to 700 ml to represent bladders of patients with different bladder filling capacities during radiotherapy. This series of models was utilized in six-field coplanar 3D conformal radiotherapy simulations with different planning target volume (PTV) margins. Each organ’s absorbed dose was calculated using the Monte Carlo method. The obtained bladder wall displacements during bladder filling were consistent with reported clinical measurements. The radiotherapy simulation revealed a linear relationship between the dose to non-targeted organs and the intravesical volume and indicated that a 10-mm PTV margin for a large bladder and a 5-mm PTV margin for a small bladder reduce the effective dose to the bladder wall to similar degrees. However, larger bladders were associated with evident protection of the intestines. Detailed dosimetry results can be used by radiation oncologists to create more accurate, individual water preload protocols according to the patient’s anatomy and bladder capacity. PMID:27441944

  6. Commissioning of a novel microCT/RT system for small animal conformal radiotherapy

    NASA Astrophysics Data System (ADS)

    Rodriguez, Manuel; Zhou, Hu; Keall, Paul; Graves, Edward

    2009-06-01

    The purpose of this work was to commission a 120 kVp photon beam produced by a micro-computed tomography (microCT) scanner for use in irradiating mice to therapeutic doses. A variable-aperture collimator has been integrated with a microCT scanner to allow the delivery of beams with pseudocircular profiles of arbitrary width between 0.1 and 6.0 cm. The dose rate at the isocenter of the system was measured using ion chamber and gafchromic EBT film as 1.56-2.13 Gy min-1 at the water surface for field diameters between 0.2 and 6.0 cm. The dose rate decreases approximately 10% per every 5 mm depth in water for field diameters between 0.5 and 1.0 cm. The flatness, symmetry and penumbra of the beam are 3.6%, 1.0% and 0.5 mm, respectively. These parameters are sufficient to accurately conform the radiation dose delivered to target organs on mice. The irradiated field size is affected principally by the divergence of the beam. In general, the beam has appropriate dosimetric characteristics to accurately deliver the dose to organs inside the mice's bodies. Using multiple beams delivered from a variety of angular directions, targets as small as 2 mm may be irradiated while sparing surrounding tissue. This microCT/RT system is a feasible tool to irradiate mice using treatment planning and delivery methods analogous to those applied to humans.

  7. Conformal radiotherapy for lung cancer: interobservers' variability in the definition of gross tumor volume between radiologists and radiotherapists

    PubMed Central

    Tyng, Chiang J; Chojniak, Rubens; Pinto, Paula NV; Borba, Marcelle A; Bitencourt, Almir GV; Fogaroli, Ricardo C; Castro, Douglas G; Novaes, Paulo E

    2009-01-01

    Background Conformal external radiotherapy aims to improve tumor control by boosting tumor dose, reducing morbidity and sparing healthy tissues. To meet this objective careful visualization of the tumor and adjacent areas is required. However, one of the major issues to be solved in this context is the volumetric definition of the targets. This study proposes to compare the gross volume of lung tumors as delineated by specialized radiologists and radiotherapists of a cancer center. Methods Chest CT scans of a total of 23 patients all with non-small cell lung cancer, not submitted to surgery, eligible and referred to conformal radiotherapy on the Hospital A. C. Camargo (São Paulo, Brazil), during the year 2004 were analyzed. All cases were delineated by 2 radiologists and 2 radiotherapists. Only the gross tumor volume and the enlarged lymph nodes were delineated. As such, four gross tumor volumes were achieved for each one of the 23 patients. Results There was a significant positive correlation between the 2 measurements (among the radiotherapists, radiologists and intra-class) and there was randomness in the distribution of data within the constructed confidence interval. Conclusion There were no significant differences in the definition of gross tumor volume between radiologists and radiotherapists. PMID:19653915

  8. The role of PET-CT in radiotherapy planning of solid tumours

    PubMed Central

    Jelercic, Stasa; Rajer, Mirjana

    2015-01-01

    Background PET-CT is becoming more and more important in various aspects of oncology. Until recently it was used mainly as part of diagnostic procedures and for evaluation of treatment results. With development of personalized radiotherapy, volumetric and radiobiological characteristics of individual tumour have become integrated in the multistep radiotherapy (RT) planning process. Standard anatomical imaging used to select and delineate RT target volumes can be enriched by the information on tumour biology gained by PET-CT. In this review we explore the current and possible future role of PET-CT in radiotherapy treatment planning. After general explanation, we assess its role in radiotherapy of those solid tumours for which PET-CT is being used most. Conclusions In the nearby future PET-CT will be an integral part of the most radiotherapy treatment planning procedures in an every-day clinical practice. Apart from a clear role in radiation planning of lung cancer, with forthcoming clinical trials, we will get more evidence of the optimal use of PET-CT in radiotherapy planning of other solid tumours. PMID:25810695

  9. Predictors of IMRT and Conformal Radiotherapy Use in Head and Neck Squamous Cell Carcinoma: A SEER-Medicare Analysis

    SciTech Connect

    Sher, David J.; Neville, Bridget A.; Chen, Aileen B.; Schrag, Deborah

    2011-11-15

    Purpose: The extent to which new techniques for the delivery of radiotherapy for head and neck squamous cell carcinoma (HNSCC) have diffused into clinical practice is unclear, including the use of 3-dimensional conformal RT (3D-RT) and intensity-modulated radiation therapy (IMRT). Methods and Materials: Using the Surveillance, Epidemiology, and End Results (SEER)-Medicare linked database, we identified 2,495 Medicare patients with Stage I-IVB HNSCC diagnosed at age 65 years or older between 2000 and 2005 and treated with either definitive (80%) or adjuvant (20%) radiotherapy. Our primary aim was to analyze the trends and predictors of IMRT use over this time, and the secondary aim was a similar description of the trends and predictors of conformal radiotherapy (CRT) use, defined as treatment with either 3D-RT or IMRT. Results: Three hundred sixty-four (15%) patients were treated with IMRT, and 1,190 patients (48%) were treated with 3D-RT. Claims for IMRT and CRT rose from 0% to 33% and 39% to 86%, respectively, between 2000 and 2005. On multivariable analysis, IMRT use was associated with SEER region (West 18%; Northeast 11%; South 12%; Midwest 13%), advanced stage (advanced, 21%; early, 9%), non-larynx site (non-larynx, 23%; larynx, 7%), higher median census tract income (highest vs. lowest quartile, 18% vs. 10%), treatment year (2003-2005, 31%; 2000-2002, 6%), use of chemotherapy (26% with; 9% without), and higher radiation oncologist treatment volume (highest vs. lowest tertile, 23% vs. 8%). With CRT as the outcome, only SEER region, treatment year, use of chemotherapy, and increasing radiation oncologist HNSCC volume were significant on multivariable analysis. Conclusions: The use of IMRT and CRT by Medicare beneficiaries with HNSCC rose significantly between 2000 and 2005 and was associated with both clinical and non-clinical factors, with treatment era and radiation oncologist HNSCC treatment volume serving as the strongest predictors of IMRT use.

  10. Conformal radiotherapy, reduced boost volume, hyperfractionated radiotherapy, and online quality control in standard-risk medulloblastoma without chemotherapy: Results of the French M-SFOP 98 protocol

    SciTech Connect

    Carrie, Christian . E-mail: carrie@lyon.fnclcc.fr; Muracciole, Xavier; Gomez, Frederic

    2005-11-01

    Purpose: Between December 1998 and October 2001, patients <19 years old were treated for standard-risk medulloblastoma according to the Medulloblastome-Societe Francaise d'Oncologie Pediatrique 1998 (M-SFOP 98) protocol. Patients received hyperfractionated radiotherapy (36 Gy in 36 fractions) to the craniospinal axis, a boost with conformal therapy restricted to the tumor bed (to a total dose of 68 Gy in 68 fractions), and no chemotherapy. Records of craniospinal irradiation were reviewed before treatment start. Results: A total of 48 patients were considered assessable. With a median follow-up of 45.7 months, the overall survival and progression-free survival rate at 3 years was 89% and 81%, respectively. Fourteen major deviations were detected and eight were corrected. No relapses occurred in the frontal region and none occurred in the posterior fossa outside the boost volume. Nine patients were available for volume calculation without reduction of the volume irradiated. We observed a reduction in the subtentorial volume irradiated to >60 Gy, but a slight increase in the volume irradiated to 40 Gy. No decrease in intelligence was observed in the 22 children tested during the first 2 years. Conclusion: This hyperfractionated radiotherapy protocol with a reduced boost volume and without chemotherapy was not associated with early relapses in children. Moreover, intellectual function seemed to be preserved. These results are promising.

  11. Forward treatment planning for modulated electron radiotherapy (MERT) employing Monte Carlo methods

    SciTech Connect

    Henzen, D. Manser, P.; Frei, D.; Volken, W.; Born, E. J.; Lössl, K.; Aebersold, D. M.; Fix, M. K.; Neuenschwander, H.; Stampanoni, M. F. M.

    2014-03-15

    Purpose: This paper describes the development of a forward planning process for modulated electron radiotherapy (MERT). The approach is based on a previously developed electron beam model used to calculate dose distributions of electron beams shaped by a photon multi leaf collimator (pMLC). Methods: As the electron beam model has already been implemented into the Swiss Monte Carlo Plan environment, the Eclipse treatment planning system (Varian Medical Systems, Palo Alto, CA) can be included in the planning process for MERT. In a first step, CT data are imported into Eclipse and a pMLC shaped electron beam is set up. This initial electron beam is then divided into segments, with the electron energy in each segment chosen according to the distal depth of the planning target volume (PTV) in beam direction. In order to improve the homogeneity of the dose distribution in the PTV, a feathering process (Gaussian edge feathering) is launched, which results in a number of feathered segments. For each of these segments a dose calculation is performed employing the in-house developed electron beam model along with the macro Monte Carlo dose calculation algorithm. Finally, an automated weight optimization of all segments is carried out and the total dose distribution is read back into Eclipse for display and evaluation. One academic and two clinical situations are investigated for possible benefits of MERT treatment compared to standard treatments performed in our clinics and treatment with a bolus electron conformal (BolusECT) method. Results: The MERT treatment plan of the academic case was superior to the standard single segment electron treatment plan in terms of organs at risk (OAR) sparing. Further, a comparison between an unfeathered and a feathered MERT plan showed better PTV coverage and homogeneity for the feathered plan, with V{sub 95%} increased from 90% to 96% and V{sub 107%} decreased from 8% to nearly 0%. For a clinical breast boost irradiation, the MERT plan

  12. Development of a Micro-Computed Tomography-Based Image-Guided Conformal Radiotherapy System for Small Animals

    SciTech Connect

    Zhou Hu; Rodriguez, Manuel; Haak, Fred van den; Nelson, Geoffrey; Jogani, Rahil

    2010-09-01

    Purpose: To report on the physical aspects of a system in which radiotherapy functionality was added to a micro-computed tomography (microCT) scanner, to evaluate the accuracy of this instrument, and to and demonstrate the application of this technology for irradiating tumors growing within the lungs of mice. Methods and Materials: A GE eXplore RS120 microCT scanner was modified by the addition of a two-dimensional subject translation stage and a variable aperture collimator. Quality assurance protocols for these devices, including measurement of translation stage positioning accuracy, collimator aperture accuracy, and collimator alignment with the X-ray beam, were devised. Use of this system for image-guided radiotherapy was assessed by irradiation of a solid water phantom as well as of two mice bearing spontaneous MYC-induced lung tumors. Radiation damage was assessed ex vivo by immunohistochemical detection of {gamma}H2AX foci. Results: The positioning error of the translation stage was found to be <0.05 mm, whereas after alignment of the collimator with the X-ray axis through adjustment of its displacement and rotation, the collimator aperture error was <0.1 mm measured at isocenter. Computed tomography image-guided treatment of a solid water phantom demonstrated target localization accuracy to within 0.1 mm. Gamma-H2AX foci were detected within irradiated lung tumors in mice, with contralateral lung tissue displaying background staining. Conclusions: Addition of radiotherapy functionality to a microCT scanner is an effective means of introducing image-guided radiation treatments into the preclinical setting. This approach has been shown to facilitate small-animal conformal radiotherapy while leveraging existing technology.

  13. Incidental irradiation of internal mammary lymph nodes in breast cancer: conventional two-dimensional radiotherapy versus conformal three-dimensional radiotherapy*

    PubMed Central

    Leite, Elton Trigo Teixeira; Ugino, Rafael Tsuneki; Santana, Marco Antônio; Ferreira, Denis Vasconcelos; Lopes, Maurício Russo; Pelosi, Edilson Lopes; da Silva, João Luis Fernandes; Carvalho, Heloisa de Andrade

    2016-01-01

    Objective To evaluate incidental irradiation of the internal mammary lymph nodes (IMLNs) through opposed tangential fields with conventional two-dimensional (2D) or three-dimensional (3D) radiotherapy techniques and to compare the results between the two techniques. Materials and Methods This was a retrospective study of 80 breast cancer patients in whom radiotherapy of the IMLNs was not indicated: 40 underwent 2D radiotherapy with computed tomography for dosimetric control, and 40 underwent 3D radiotherapy. The total prescribed dose was 50.0 Gy or 50.4 Gy (2.0 or 1.8 Gy/day, respectively). We reviewed all plans and defined the IMLNs following the Radiation Therapy Oncology Group recommendations. For the IMLNs, we analyzed the proportion of the volume that received 45 Gy, the proportion of the volume that received 25 Gy, the dose to 95% of the volume, the dose to 50% of the volume, the mean dose, the minimum dose (Dmin), and the maximum dose (Dmax). Results Left-sided treatments predominated in the 3D cohort. There were no differences between the 2D and 3D cohorts regarding tumor stage, type of surgery (mastectomy, breast-conserving surgery, or mastectomy with immediate reconstruction), or mean delineated IMLN volume (6.8 vs. 5.9 mL; p = 0.411). Except for the Dmin, all dosimetric parameters presented higher mean values in the 3D cohort (p < 0.05). The median Dmax in the 3D cohort was 50.34 Gy. However, the mean dose to the IMLNs was 7.93 Gy in the 2D cohort, compared with 20.64 Gy in the 3D cohort. Conclusion Neither technique delivered enough doses to the IMLNs to achieve subclinical disease control. However, all of the dosimetric parameters were significantly higher for the 3D technique. PMID:27403017

  14. 40 CFR 93.107 - Relationship of transportation plan and TIP conformity with the NEPA process.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... quality modeling do not preclude the consideration of alternatives in the NEPA process or other project... and TIP conformity with the NEPA process. 93.107 Section 93.107 Protection of Environment... Transit Laws § 93.107 Relationship of transportation plan and TIP conformity with the NEPA process....

  15. Improvement in toxicity in high risk prostate cancer patients treated with image-guided intensity-modulated radiotherapy compared to 3D conformal radiotherapy without daily image guidance

    PubMed Central

    2014-01-01

    Background Image-guided radiotherapy (IGRT) facilitates the delivery of a very precise radiation dose. In this study we compare the toxicity and biochemical progression-free survival between patients treated with daily image-guided intensity-modulated radiotherapy (IG-IMRT) and 3D conformal radiotherapy (3DCRT) without daily image guidance for high risk prostate cancer (PCa). Methods A total of 503 high risk PCa patients treated with radiotherapy (RT) and endocrine treatment between 2000 and 2010 were retrospectively reviewed. 115 patients were treated with 3DCRT, and 388 patients were treated with IG-IMRT. 3DCRT patients were treated to 76 Gy and without daily image guidance and with 1–2 cm PTV margins. IG-IMRT patients were treated to 78 Gy based on daily image guidance of fiducial markers, and the PTV margins were 5–7 mm. Furthermore, the dose-volume constraints to both the rectum and bladder were changed with the introduction of IG-IMRT. Results The 2-year actuarial likelihood of developing grade > = 2 GI toxicity following RT was 57.3% in 3DCRT patients and 5.8% in IG-IMRT patients (p < 0.001). For GU toxicity the numbers were 41.8% and 29.7%, respectively (p = 0.011). On multivariate analysis, 3DCRT was associated with a significantly increased risk of developing grade > = 2 GI toxicity compared to IG-IMRT (p < 0.001, HR = 11.59 [CI: 6.67-20.14]). 3DCRT was also associated with an increased risk of developing GU toxicity compared to IG-IMRT. The 3-year actuarial biochemical progression-free survival probability was 86.0% for 3DCRT and 90.3% for IG-IMRT (p = 0.386). On multivariate analysis there was no difference in biochemical progression-free survival between 3DCRT and IG-IMRT. Conclusion The difference in toxicity can be attributed to the combination of the IMRT technique with reduced dose to organs-at-risk, daily image guidance and margin reduction. PMID:24495815

  16. Effective avoidance of a functional spect-perfused lung using intensity modulated radiotherapy (IMRT) for non-small cell lung cancer (NSCLC): an update of a planning study.

    PubMed

    Lavrenkov, Konstantin; Singh, Shalini; Christian, Judith A; Partridge, Mike; Nioutsikou, Elena; Cook, Gary; Bedford, James L; Brada, Michael

    2009-06-01

    IMRT and 3-dimensional conformal radiotherapy (3-DCRT) plans of 25 patients with non-small cell lung (NSCLC) were compared in terms of planning target volume (PTV) coverage and sparing of functional lung (FL) defined by a SPECT perfusion scan. IMRT resulted in significant reduction of functional V(20) and mean lung dose in stage III patients with inhomogeneous hypoperfusion. If the dose to FL is shown to be the determinant of lung toxicity, IMRT would allow for effective dose escalation by specific avoidance of functional lung. PMID:18995919

  17. Dosimetric Comparison of Involved-Field Three-Dimensional Conformal Photon Radiotherapy and Breast-Sparing Proton Therapy for the Treatment of Hodgkin's Lymphoma in Female Pediatric Patients

    SciTech Connect

    Andolino, David L.; Hoene, Ted; Xiao, Lu; Buchsbaum, Jeffrey; Chang, Andrew L.

    2011-11-15

    Purpose: To assess the potential reduction in breast dose for young girls with Hodgkin's lymphoma (HL) treated with breast-sparing proton therapy (BS-PT) as compared with three-dimensional conformal involved-field photon radiotherapy (3D-CRT). Methods and Materials: The Clarian Health Cancer Registry was queried for female pediatric patients with the diagnosis of HL who received radiotherapy at the Indiana University Simon Cancer Center during 2006-2009. The original CT simulation images were obtained, and 3D-CRT and BS-PT plans delivering 21 Gy or cobalt gray equivalent (CGE) in 14 fractions were created for each patient. Dose-volume histogram data were collected for both 3D-CRT and BS-PT plans and compared by paired t test for correlated samples. Results: The cancer registry provided 10 female patients with Ann Arbor Stage II HL, aged 10-18 years at the time of treatment. Both mean and maximum breast dose were significantly less with BS-PT compared with 3D-CRT: 0.95 CGE vs. 4.70 Gy (p < 0.001) and 21.07 CGE vs. 23.11 Gy (p < 0.001), respectively. The volume of breast receiving 1.0 Gy/CGE and 5.0 Gy/CGE was also significantly less with BS-PT, 194 cm{sup 3} and 93 cm{sup 3}, respectively, compared with 790 cm{sup 3} and 360 cm{sup 3} with 3D-CRT (p = 0.009, 0.013). Conclusion: Breast-sparing proton therapy has the potential to reduce unnecessary breast dose in young girls with HL by as much as 80% relative to involved-field 3D-CRT.

  18. SU-E-J-267: Weekly Volumetric and Dosimetric Changes in Adaptive Conformal Radiotherapy of Non-Small-Cell-Lung Cancer Using 4D CT and Gating

    SciTech Connect

    Li, Z; Shang, Q; Xiong, F; Zhang, X; Zhang, Q; Fu, S

    2014-06-01

    Purpose: This study was to evaluate the significance of weekly imageguided patient setup and to assess the volumetric and dosimetric changes in no-small-cell-lung cancer (NSCLC) patients treated with adaptive conformal radiotherapy (CRT). Methods: 9 NSCLC patients treated with 3D CRT underwent 4D CT-on-rail every five fractions. ITV was generated from three phases of the 4DCT (the end of exhalation, 25% before and after the end of exhalation). The margin of ITV to PTV is 5mm. 6 weekly CTs were acquired for each patient. The weekly CTs were fused with the planning CT by vertebrae. The couch shift was recorded for each weekly CT to evaluate the setup error. The gross tumor volumes (GTVs) were contoured on weekly CT images by a physician. Beams from the original plans were applied to weekly CTs to calculate the delivered doses. All patients underwent replanning after 20 fractions. Results: Among the total 54 CTs, the average setup error was 2.0± 1.7, 2.6± 2.1, 2.7± 2.2 mm in X, Y, and Z direction, respectively. The average volume of the primary GTV was reduced from 42.45 cc to 22.78 cc (47.04%) after 6 weeks. The maximal volume regression occurred between 15 and 20 fractions. Adaptive radiation therapy (ART) reduced the V20 and V5 of the lung by 33.5% and 16.89%, respectively. ART also reduced Dmean and D1/3 of the heart by 31.7% and 32.32%, respectively. Dmax of the spinal cord did not vary much during the treatment course. Conclusion: 5 mm margin is sufficient for 4D weekly CTguided radiotherapy in lung cancer. Tumor regression was observed in the majority of patients. ART significantly reduced the OARs dose. Our preliminary results indicated that an off-line ART approach is appropriate in clinical practice.

  19. Risk factors for acute esophagitis in non-small-cell lung cancer patients treated with concurrent chemotherapy and three-dimensional conformal radiotherapy

    SciTech Connect

    Wei Xiong; Liu, H. Helen . E-mail: hliu@mdanderson.org; Tucker, Susan L.; Liao Zhongxing; Hu Chaosu; Mohan, Radhe; Cox, James D.; Komaki, Ritsuko

    2006-09-01

    Purpose: To determine the risk factors for acute esophagitis (AE) in non-small-cell lung cancer (NSCLC) patients treated with concurrent chemotherapy (CCT) and three-dimensional conformal radiotherapy (3D-CRT). Methods and Materials: Clinical data were retrospectively analyzed for 215 NSCLC patients treated with CCT and 3D-CRT during 2000-2003, 127 of whom also had induction chemotherapy (ICT). Carboplatin and paclitaxel were the most commonly used agents for both ICT and CCT. The median prescription dose of radiotherapy was 63.5 Gy in 35 fractions. AE was graded during each treatment week and 1-month follow-up visits. The factors related to clinical and disease characteristics, CCT and 3D-CRT treatments, and treatment planning were reviewed and analyzed for their association with Grade {>=}3 AE using univariate and multivariate logistic tests. Results: The rate of any grade AE was 93.0% and of Grade {>=}3 was 20.5%. Univariate analyses showed that none of the clinical factors was significantly associated with Grade {>=}3 AE. However, the mean radiation dose to the esophagus, the absolute esophageal volume treated above 15 Gy (aV15) through aV45 Gy, and the relative esophagus volume treated above 10 Gy (rV10) through rV45 Gy were significant risk factors for Grade {>=}3 AE. Only rV20 was retained as the single risk factor in multivariate analyses. Conclusions: The risk of AE in the NSCLC patients treated with CCT and 3D-CRT was primarily determined by dosimetric factors. These factors should be carefully considered during treatment planning to minimize the incidence of AE.

  20. Comparative study of four advanced 3d-conformal radiation therapy treatment planning techniques for head and neck cancer

    PubMed Central

    Herrassi, Mohamed Yassine; Bentayeb, Farida; Malisan, Maria Rosa

    2013-01-01

    For the head-and-neck cancer bilateral irradiation, intensity-modulated radiation therapy (IMRT) is the most reported technique as it enables both target dose coverage and organ-at-risk (OAR) sparing. However, during the last 20 years, three-dimensional conformal radiotherapy (3DCRT) techniques have been introduced, which are tailored to improve the classic shrinking field technique, as regards both planning target volume (PTV) dose conformality and sparing of OAR’s, such as parotid glands and spinal cord. In this study, we tested experimentally in a sample of 13 patients, four of these advanced 3DCRT techniques, all using photon beams only and a unique isocentre, namely Bellinzona, Forward-Planned Multisegments (FPMS), ConPas, and field-in-field (FIF) techniques. Statistical analysis of the main dosimetric parameters of PTV and OAR’s DVH’s as well as of homogeneity and conformity indexes was carried out in order to compare the performance of each technique. The results show that the PTV dose coverage is adequate for all the techniques, with the FPMS techniques providing the highest value for D95%; on the other hand, the best sparing of parotid glands is achieved using the FIF and ConPas techniques, with a mean dose of 26 Gy to parotid glands for a PTV prescription dose of 54 Gy. After taking into account both PTV coverage and parotid sparing, the best global performance was achieved by the FIF technique with results comparable to that of IMRT plans. This technique can be proposed as a valid alternative when IMRT equipment is not available or patient is not suitable for IMRT treatment. PMID:23776314

  1. Intensity-Modulated Radiotherapy for Locally Advanced Non-Small-Cell Lung Cancer: A Dose-Escalation Planning Study

    SciTech Connect

    Lievens, Yolande; Nulens, An; Gaber, Mousa Amr; Defraene, Gilles; De Wever, Walter; Stroobants, Sigrid; Van den Heuvel, Frank

    2011-05-01

    Purpose: To evaluate the potential for dose escalation with intensity-modulated radiotherapy (IMRT) in positron emission tomography-based radiotherapy planning for locally advanced non-small-cell lung cancer (LA-NSCLC). Methods and Materials: For 35 LA-NSCLC patients, three-dimensional conformal radiotherapy and IMRT plans were made to a prescription dose (PD) of 66 Gy in 2-Gy fractions. Dose escalation was performed toward the maximal PD using secondary endpoint constraints for the lung, spinal cord, and heart, with de-escalation according to defined esophageal tolerance. Dose calculation was performed using the Eclipse pencil beam algorithm, and all plans were recalculated using a collapsed cone algorithm. The normal tissue complication probabilities were calculated for the lung (Grade 2 pneumonitis) and esophagus (acute toxicity, grade 2 or greater, and late toxicity). Results: IMRT resulted in statistically significant decreases in the mean lung (p <.0001) and maximal spinal cord (p = .002 and 0005) doses, allowing an average increase in the PD of 8.6-14.2 Gy (p {<=}.0001). This advantage was lost after de-escalation within the defined esophageal dose limits. The lung normal tissue complication probabilities were significantly lower for IMRT (p <.0001), even after dose escalation. For esophageal toxicity, IMRT significantly decreased the acute NTCP values at the low dose levels (p = .0009 and p <.0001). After maximal dose escalation, late esophageal tolerance became critical (p <.0001), especially when using IMRT, owing to the parallel increases in the esophageal dose and PD. Conclusion: In LA-NSCLC, IMRT offers the potential to significantly escalate the PD, dependent on the lung and spinal cord tolerance. However, parallel increases in the esophageal dose abolished the advantage, even when using collapsed cone algorithms. This is important to consider in the context of concomitant chemoradiotherapy schedules using IMRT.

  2. Dose differences in intensity-modulated radiotherapy plans calculated with pencil beam and Monte Carlo for lung SBRT.

    PubMed

    Liu, Han; Zhuang, Tingliang; Stephans, Kevin; Videtic, Gregory; Raithel, Stephen; Djemil, Toufik; Xia, Ping

    2015-01-01

    For patients with medically inoperable early-stage non-small cell lung cancer (NSCLC) treated with stereotactic body radiation therapy, early treatment plans were based on a simpler dose calculation algorithm, the pencil beam (PB) calculation. Because these patients had the longest treatment follow-up, identifying dose differences between the PB calculated dose and Monte Carlo calculated dose is clinically important for understanding of treatment outcomes. Previous studies found significant dose differences between the PB dose calculation and more accurate dose calculation algorithms, such as convolution-based or Monte Carlo (MC), mostly for three-dimensional conformal radiotherapy (3D CRT) plans. The aim of this study is to investigate whether these observed dose differences also exist for intensity-modulated radiotherapy (IMRT) plans for both centrally and peripherally located tumors. Seventy patients (35 central and 35 peripheral) were retrospectively selected for this study. The clinical IMRT plans that were initially calculated with the PB algorithm were recalculated with the MC algorithm. Among these paired plans, dosimetric parameters were compared for the targets and critical organs. When compared to MC calculation, PB calculation overestimated doses to the planning target volumes (PTVs) of central and peripheral tumors with different magnitudes. The doses to 95% of the central and peripheral PTVs were overestimated by 9.7% ± 5.6% and 12.0% ± 7.3%, respectively. This dose overestimation did not affect doses to the critical organs, such as the spinal cord and lung. In conclusion, for NSCLC treated with IMRT, dose differences between the PB and MC calculations were different from that of 3D CRT. No significant dose differences in critical organs were observed between the two calculations. PMID:26699560

  3. Dosimetric evaluation of a simple planning method for improving intensity-modulated radiotherapy for stage III lung cancer

    PubMed Central

    Lu, Jia-Yang; Lin, Zhu; Zheng, Jing; Lin, Pei-Xian; Cheung, Michael Lok-Man; Huang, Bao-Tian

    2016-01-01

    This study aimed to evaluate the dosimetric outcomes of a base-dose-plan-compensation (BDPC) planning method for improving intensity-modulated radiotherapy (IMRT) for stage III lung cancer. For each of the thirteen included patients, three types of planning methods were applied to obtain clinically acceptable plans: (1) the conventional optimization method (CO); (2) a split-target optimization method (STO), in which the optimization objectives were set higher dose for the target with lung density; (3) the BDPC method, which compensated for the optimization-convergence error by further optimization based on the CO plan. The CO, STO and BDPC methods were then compared regarding conformity index (CI), homogeneity index (HI) of the target, organs at risk (OARs) sparing and monitor units (MUs). The BDPC method provided better HI/CI by 54%/7% on average compared to the CO method and by 38%/3% compared to the STO method. The BDPC method also spared most of the OARs by up to 9%. The average MUs of the CO, STO and BDPC plans were 890, 937 and 1023, respectively. Our results indicated that the BDPC method can effectively improve the dose distribution in IMRT for stage III lung cancer, at the expense of more MUs. PMID:27009235

  4. Dosimetric evaluation of a simple planning method for improving intensity-modulated radiotherapy for stage III lung cancer.

    PubMed

    Lu, Jia-Yang; Lin, Zhu; Zheng, Jing; Lin, Pei-Xian; Cheung, Michael Lok-Man; Huang, Bao-Tian

    2016-01-01

    This study aimed to evaluate the dosimetric outcomes of a base-dose-plan-compensation (BDPC) planning method for improving intensity-modulated radiotherapy (IMRT) for stage III lung cancer. For each of the thirteen included patients, three types of planning methods were applied to obtain clinically acceptable plans: (1) the conventional optimization method (CO); (2) a split-target optimization method (STO), in which the optimization objectives were set higher dose for the target with lung density; (3) the BDPC method, which compensated for the optimization-convergence error by further optimization based on the CO plan. The CO, STO and BDPC methods were then compared regarding conformity index (CI), homogeneity index (HI) of the target, organs at risk (OARs) sparing and monitor units (MUs). The BDPC method provided better HI/CI by 54%/7% on average compared to the CO method and by 38%/3% compared to the STO method. The BDPC method also spared most of the OARs by up to 9%. The average MUs of the CO, STO and BDPC plans were 890, 937 and 1023, respectively. Our results indicated that the BDPC method can effectively improve the dose distribution in IMRT for stage III lung cancer, at the expense of more MUs. PMID:27009235

  5. A Treatment Planning Study of Stereotactic Body Radiotherapy for Atrial Fibrillation

    PubMed Central

    Kotecha, Rupesh; Sharma, Naveen; Andrews, Martin; Stephans, Kevin L; Oberti, Carlos; Lin, Sara; Wazni, Oussama; Tchou, Patrick; Saliba, Walid I; Suh, John

    2016-01-01

    Purpose: To explore the feasibility of using stereotactic body radiotherapy (SBRT) to irradiate the antra of the four pulmonary veins while protecting nearby critical organs, such as the esophagus. Materials and Methods: Twenty patients who underwent radiofrequency catheter ablation for atrial fibrillation were selected. For each patient, the antra of the four pulmonary veins were identified as the target volumes on a pre-catheterization contrast or non-contrast CT scan. On each CT scan, the esophagus, trachea, heart, and total lung were delineated and the esophagus was identified as the critical organ. For each patient, three treatment plans were designed with 0, 2, and 5 mm planning margins around the targets while avoiding overlap with a planning organ at risk volume (PRV) generated by a 2 mm expansion of the esophagus. Using three non-coplanar volumetric modulated arcs (VMAT), 60 plans were created to deliver a prescription dose of 50 Gy in five fractions, following the SBRT dose regimen for central lung tumors. With greater than 97% of the planning target volumes (PTV) receiving the prescription doses, we examined dosimetry to 0.03 cc and 5 cc of the esophagus PRV volume as well as other contoured structures. Results: The average PTV-0 mm, PTV-2 mm, and PTV-5 mm volumes were 3.05 ± 1.90 cc, 14.70 ± 5.00 cc, and 40.85 ± 10.20 cc, respectively. With three non-coplanar VMAT arcs, the average conformality indices (ratio of prescription isodose volume to the PTV volume) for the PTV-0 mm, PTV-2 mm and PTV-5 mm were 4.81 ± 2.0, 1.71 ± 0.19, and 1.23 ± 0.08, respectively. Assuming patients were treated under breath-hold with 2 mm planning margins to account for cardiac motion, all plans met esophageal PRV maximum dose limits < 50 Gy to 0.03 cc and 16 plans (80%) met < 27.5 Gy to 5 cc of the esophageal PRVs. For PTV-5 mm plans, 18 plans met the maximum dose limit < 50 Gy to 0.03 cc and only two plans met the maximum dose limit < 27.5 Gy to 5 cc of the

  6. The NUKDOS software for treatment planning in molecular radiotherapy.

    PubMed

    Kletting, Peter; Schimmel, Sebastian; Hänscheid, Heribert; Luster, Markus; Fernández, Maria; Nosske, Dietmar; Lassmann, Michael; Glatting, Gerhard

    2015-09-01

    The aim of this work was the development of a software tool for treatment planning prior to molecular radiotherapy, which comprises all functionality to objectively determine the activity to administer and the pertaining absorbed doses (including the corresponding error) based on a series of gamma camera images and one SPECT/CT or probe data. NUKDOS was developed in MATLAB. The workflow is based on the MIRD formalism For determination of the tissue or organ pharmacokinetics, gamma camera images as well as probe, urine, serum and blood activity data can be processed. To estimate the time-integrated activity coefficients (TIAC), sums of exponentials are fitted to the time activity data and integrated analytically. To obtain the TIAC on the voxel level, the voxel activity distribution from the quantitative 3D SPECT/CT (or PET/CT) is used for scaling and weighting the TIAC derived from the 2D organ data. The voxel S-values are automatically calculated based on the voxel-size of the image and the therapeutic nuclide ((90)Y, (131)I or (177)Lu). The absorbed dose coefficients are computed by convolution of the voxel TIAC and the voxel S-values. The activity to administer and the pertaining absorbed doses are determined by entering the absorbed dose for the organ at risk. The overall error of the calculated absorbed doses is determined by Gaussian error propagation. NUKDOS was tested for the operation systems Windows(®) 7 (64 Bit) and 8 (64 Bit). The results of each working step were compared to commercially available (SAAMII, OLINDA/EXM) and in-house (UlmDOS) software. The application of the software is demonstrated using examples form peptide receptor radionuclide therapy (PRRT) and from radioiodine therapy of benign thyroid diseases. For the example from PRRT, the calculated activity to administer differed by 4% comparing NUKDOS and the final result using UlmDos, SAAMII and OLINDA/EXM sequentially. The absorbed dose for the spleen and tumour differed by 7% and 8

  7. Low-Dose-Rate Californium-252 Neutron Intracavitary Afterloading Radiotherapy Combined With Conformal Radiotherapy for Treatment of Cervical Cancer

    SciTech Connect

    Zhang Min; Xu Hongde; Pan Songdan; Lin Shan; Yue Jianhua; Liu Jianren

    2012-07-01

    Purpose: To study the efficacy of low-dose-rate californium-252 ({sup 252}Cf) neutron intracavitary afterloading radiotherapy (RT) combined with external pelvic RT for treatment of cervical cancer. Methods and Materials: The records of 96 patients treated for cervical cancer from 2006 to 2010 were retrospectively reviewed. For patients with tumors {<=}4 cm in diameter, external beam radiation was performed (1.8 Gy/day, five times/week) until the dose reached 20 Gy, and then {sup 252}Cf neutron intracavitary afterloading RT (once/week) was begun, and the frequency of external beam radiation was changed to four times/week. For patients with tumors >4 cm, {sup 252}Cf RT was performed one to two times before whole-pelvis external beam radiation. The tumor-eliminating dose was determined by using the depth limit of 5 mm below the mucosa as the reference point. In all patients, the total dose of the external beam radiation ranged from 46.8 to 50 Gy. For {sup 252}Cf RT, the dose delivered to point A was 6 Gy/fraction, once per week, for a total of seven times, and the total dose was 42 Gy. Results: The mean {+-} SD patient age was 54.7 {+-} 13.7 years. Six patients had disease assessed at stage IB, 13 patients had stage IIA, 49 patients had stage IIB, 3 patients had stage IIIA, 24 patients had stage IIIB, and 1 patient had stage IVA. All patients obtained complete tumor regression (CR). The mean {+-} SD time to CR was 23.5 {+-} 3.4 days. Vaginal bleeding was fully controlled in 80 patients within 1 to 8 days. The mean {+-} SD follow-up period was 27.6 {+-} 12.7 months (range, 6-48 months). Five patients died due to recurrence or metastasis. The 3-year survival and disease-free recurrence rates were 89.6% and 87.5 %, respectively. Nine patients experienced mild radiation proctitis, and 4 patients developed radiocystitis. Conclusions: Low-dose-rate {sup 252}Cf neutron RT combined with external pelvic RT is effective for treating cervical cancer, with a low incidence of

  8. The feasibility of atlas-based automatic segmentation of MRI for H&N radiotherapy planning.

    PubMed

    Wardman, Kieran; Prestwich, Robin J D; Gooding, Mark J; Speight, Richard J

    2016-01-01

    Atlas-based autosegmentation is an established tool for segmenting structures for CT-planned head and neck radiotherapy. MRI is being increasingly integrated into the planning process. The aim of this study is to assess the feasibility of MRI-based, atlas-based autosegmentation for organs at risk (OAR) and lymph node levels, and to compare the segmentation accuracy with CT-based autosegmentation. Fourteen patients with locally advanced head and neck cancer in a prospective imaging study underwent a T1-weighted MRI and a PET-CT (with dedicated contrast-enhanced CT) in an immobilization mask. Organs at risk (orbits, parotids, brainstem, and spinal cord) and the left level II lymph node region were manually delineated on the CT and MRI separately. A 'leave one out' approach was used to automatically segment structures onto the remaining images separately for CT and MRI. Contour comparison was performed using multiple positional metrics: Dice index, mean distance to conformity (MDC), sensitivity index (Se Idx), and inclusion index (Incl Idx). Automatic segmentation using MRI of orbits, parotids, brainstem, and lymph node level was acceptable with a DICE coefficient of 0.73-0.91, MDC 2.0-5.1mm, Se Idx 0.64-0.93, Incl Idx 0.76-0.93. Segmentation of the spinal cord was poor (Dice coefficient 0.37). The process of automatic segmentation was significantly better on MRI compared to CT for orbits, parotid glands, brainstem, and left lymph node level II by multiple positional metrics; spinal cord segmentation based on MRI was inferior compared with CT. Accurate atlas-based automatic segmentation of OAR and lymph node levels is feasible using T1-MRI; segmentation of the spinal cord was found to be poor. Comparison with CT-based automatic segmentation suggests that the process is equally as, or more accurate, using MRI. These results support further translation of MRI-based segmentation methodology into clinicalpractice. PMID:27455480

  9. Investigation on the performance of dedicated radiotherapy positioning devices for MR scanning for prostate planning.

    PubMed

    Sun, Jidi; Dowling, Jason A; Pichler, Peter; Parker, Joel; Martin, Jarad; Stanwell, Peter; Arm, Jameen; Menk, Fred; Greer, Peter B

    2015-01-01

    The purpose of this study was to investigate performance of the couch and coil mounts designed for MR-simulation prostate scanning using data from ten volunteers. Volunteers were scanned using the standard MR scanning protocol with the MR coil directly strapped on the external body and the volunteer lying on the original scanner table. They also were scanned using a MR-simulation table top and pelvic coil mounts. MR images from both setups were compared in terms of body contour variation and image quality effects within particular organs of interest. Six-field conformal plans were generated on the two images with assigned bulk density for dose calculation. With the MR-simulation devices, the anterior skin deformation was reduced by up to 1.7 cm. The hard tabletop minimizes the posterior body deformation which can be up to 2.3 cm on the standard table, depending on the weight of volunteer. The image signal-to-noise ratio reduced by 14% and 25% on large field of view (FOV) and small FOV images, respectively, after using the coil mount; the prostate volume contoured on two images showed difference of 1.05 ± 0.66 cm3. The external body deformation caused a mean dose reduction of 0.6 ± 0.3 Gy, while the coverage reduced by 22% ± 13% and 27% ± 6% in V98 and V100, respectively. A dedicated MR simulation setup for prostate radiotherapy is essential to ensure the agreement between planning anatomy and treatment anatomy. The image signal was reduced after applying the coil mount, but no significant effect was found on prostate contouring. PMID:26103166

  10. Guidelines for delineation of lymphatic clinical target volumes for high conformal radiotherapy: head and neck region

    PubMed Central

    2011-01-01

    The success of radiotherapy depends on the accurate delineation of the clinical target volume. The delineation of the lymph node regions has most impact, especially for tumors in the head and neck region. The purpose of this article was the development an atlas for the delineation of the clinical target volume for patients, who should receive radiotherapy for a tumor of the head and neck region. Literature was reviewed for localisations of the adjacent lymph node regions and their lymph drain in dependence of the tumor entity. On this basis the lymph node regions were contoured on transversal CT slices. The probability for involvement was reviewed and a recommendation for the delineation of the CTV was generated. PMID:21854585

  11. A Retrospective Comparison of Robotic Stereotactic Body Radiotherapy and Three-Dimensional Conformal Radiotherapy for the Reirradiation of Locally Recurrent Nasopharyngeal Carcinoma

    SciTech Connect

    Ozyigit, Gokhan; Cengiz, Mustafa; Yazici, Gozde; Yildiz, Ferah; Gurkaynak, Murat; Zorlu, Faruk; Yildiz, Demet; Hosal, Sefik; Gullu, Ibrahim; Akyol, Fadil

    2011-11-15

    Purpose: We assessed therapeutic outcomes of reirradiation with robotic stereotactic radiotherapy (SBRT) for locally recurrent nasopharyngeal carcinoma (LRNPC) patients and compared those results with three-dimensional conformal radiotherapy (CRT) with or without brachytherapy (BRT). Methods and Materials: Treatment outcomes were evaluated retrospectively in 51 LRNPC patients receiving either robotic SBRT (24 patients) or CRT with or without BRT (27 patients) in our department. CRT was delivered with a 6-MV linear accelerator, and a median total reirradiation dose of 57 Gy in 2 Gy/day was given. Robotic SBRT was delivered with CyberKnife (Accuray, Sunnyvale, CA). Patients in the SBRT arm received 30 Gy over 5 consecutive days. We calculated actuarial local control and cancer-specific survival rates for the comparison of treatment outcomes in SBRT and CRT arms. The Common Terminology Criteria for Adverse Events v3.0 was used for toxicity evaluation. Results: The median follow-up was 24 months for all patients. Two-year actuarial local control rates were 82% and 80% for SBRT and CRT arms, respectively (p = 0.6). Two-year cancer-specific survival rates were 64% and 47% for the SBRT and CRT arms, respectively (p = 0.4). Serious late toxicities (Grade 3 and above) were observed in 21% of patients in the SBRT arm, whereas 48% of patients had serious toxicity in the CRT arm (p = 0.04). Fatal complications occurred in three patients (12.5%) of the SBRT arm, and four patients (14.8%) of the CRT arm (p = 0.8). T stage at recurrence was the only independent predictor for local control and survival. Conclusion: Our robotic SBRT protocol seems to be feasible and less toxic in terms of late effects compared with CRT arm for the reirradiation of LRNPC patients.

  12. Quality of Life and Survival Outcome for Patients With Nasopharyngeal Carcinoma Receiving Three-Dimensional Conformal Radiotherapy vs. Intensity-Modulated Radiotherapy-A Longitudinal Study

    SciTech Connect

    Fang, F.-M. Chien, C.-Y.; Tsai, W.-L.; Chen, H.-C.; Hsu, H.-C.; Lui, C.-C.; Huang, T.-L.

    2008-10-01

    Purpose: To investigate the changes of quality of life (QoL) and survival outcomes for patients with nasopharyngeal carcinoma (NPC) treated by three-dimensional conformal radiotherapy (3D-CRT) vs. intensity-modulated radiotherapy (IMRT). Methods and Materials: Two hundred and three newly diagnosed NPC patients, who were curatively treated by 3D-CRT (n = 93) or IMRT (n = 110) between March 2002 and July 2004, were analyzed. The distributions of clinical stage according to American Joint Committee on Cancer 1997 were I: 15 (7.4%), II: 78 (38.4%), III: 74 (36.5%), and IV: 36 (17.7%). QoL was longitudinally assessed by the European Organization for Research and Treatment of Cancer (EORTC) QLQ-C30 and the EORTC QLQ-H and N35 questionnaires at the five time points: before RT, during RT (36 Gy), and 3 months, 12 months, and 24 months after RT. Results: The 3-year locoregional control, metastasis-free survival, and overall survival rates were 84.8%, 76.7%, and 81.7% for the 3D-CRT group, respectively, compared with 84.2%, 82.6%, and 85.4% for the IMRT group (p value > 0.05). A general trend of maximal deterioration in most QoL scales was observed during RT, followed by a gradual recovery thereafter. There was no significant difference in most scales between the two groups at each time point. The exception was that patients treated by IMRT had a both statistically and clinically significant improvement in global QoL, fatigue, taste/smell, dry mouth, and feeling ill at the time point of 3 months after RT. Conclusions: The potential advantage of IMRT over 3D-CRT in treating NPC patients might occur in QoL outcome during the recovery phase of acute toxicity.

  13. Phase II Study of Vinorelbine and Estramustine in Combination With Conformational Radiotherapy for Patients With High-Risk Prostate Cancer

    SciTech Connect

    Carles, Joan; Nogue, Miguel; Sole, Josep M.; Foro, Palmira; Domenech, Montserrat; Suarez, Marta; Gallardo, Enrique; Garcia, Dario; Ferrer, Ferran; Gelabert-Mas, Antoni; Gayo, Javier; Fabregat, Xavier

    2010-03-15

    Purpose: To evaluate the efficacy and safety profile of vinorelbine and estramustine in combination with three-dimensional conformational radiotherapy (3D-CRT) in patients with localized high-risk prostate cancer. Methods and Materials: Fifty patients received estramustine, 600 mg/m{sup 2} daily, and vinorelbine, 25 mg/m{sup 2}, on days 1 and 8 of a 21-day cycle for three cycles in combination with 8 weeks of 3D-CRT (total dose of 70.2 gray [Gy] at 1.8-Gy fractions or 70 Gy at 2.0-Gy fractions). Additionally, patients received luteinizing hormone-releasing hormone analogs for 3 years. Results: All patients were evaluated for response and toxicity. Progression-free survival at 5 years was 72% (95% confidence interval [CI]: 52-86). All patients who relapsed had only biochemical relapse. The most frequent severe toxicities were cystitis (16% of patients), leucopenia (10% of patients), diarrhea (10% of patients), neutropenia (8% of patients), and proctitis (8% of patients). Six patients (12%) did not complete study treatment due to the patient's decision (n = 1) and to adverse events such as hepatotoxicity, proctitis, paralytic ileus, and acute myocardial infarction. Conclusions: Vinorelbine and estramustine in combination with 3D-CRT is a safe and effective regimen for patients with localized high-risk prostate cancer. A randomized trial is needed to determine whether the results of this regimen are an improvement over the results obtained with radiotherapy and androgen ablation.

  14. Acute and Late Toxicity in a Randomized Trial of Conventional Versus Hypofractionated Three-Dimensional Conformal Radiotherapy for Prostate Cancer

    SciTech Connect

    Arcangeli, Giorgio; Fowler, Jack; Gomellini, Sara; Arcangeli, Stefano; Saracino, Biancamaria; Petrongari, Maria Grazia; Benassi, Marcello; Strigari, Lidia

    2011-03-15

    Purpose: To compare the toxicity between hypofractionation vs. conventional fractionation schedules in patients with high-risk prostate cancer. Methods and Materials: Between January 2003 and December 2007, 168 patients were randomized to receive either hypofractionated (62 Gy in 20 fractions within 5 weeks, 4 fractions/wk) or conventionally fractionated (80 Gy in 40 fractions within 8 weeks) three-dimensional conformal radiotherapy to the prostate and seminal vesicles. All patients had undergone a 9-month course of total androgen deprivation, with radiotherapy starting 2 months after initiation of the total androgen deprivation. Results: The median follow-up was 32 and 35 months in the hypofractionation and conventional fractionation arms, respectively. For the patients developing acute toxicity, no difference between the two fractionation groups was found in either severity or duration of gastrointestinal or genitourinary toxicity. Also, no difference was found in the incidence and severity of late gastrointestinal and genitourinary toxicity between the two treatment schedules, with a 3-year rate of Grade 2 or greater toxicity of 17% and 16% for the hypofractionation arm and 14% and 11% for the conventional fractionation arm, respectively. A statistically significant correlation between acute and late gastrointestinal toxicity was found only in the conventional fractionation group. Conclusion: Our findings suggest that the hypofractionation regimen used in our study is safe, with only a slight, nonsignificant increase in tolerable and temporary acute toxicity compared with the conventional fractionation schedule. The severity and frequency of late complications was equivalent between the two treatment groups.

  15. Tracking the dynamic seroma cavity using fiducial markers in patients treated with accelerated partial breast irradiation using 3D conformal radiotherapy

    SciTech Connect

    Yue, Ning J.; Haffty, Bruce G.; Goyal, Sharad

    2013-02-15

    Purpose: The purpose of the present study was to perform an analysis of the changes in the dynamic seroma cavity based on fiducial markers in early stage breast cancer patients treated with accelerated partial breast irradiation (APBI) using three-dimensional conformal external beam radiotherapy (3D-CRT). Methods: A prospective, single arm trial was designed to investigate the utility of gold fiducial markers in image guided APBI using 3D-CRT. At the time of lumpectomy, four to six suture-type gold fiducial markers were sutured to the walls of the cavity. Patients were treated with a fractionation scheme consisting of 15 fractions with a fractional dose of 333 cGy. Treatment design and planning followed NSABP/RTOG B-39 guidelines. During radiation treatment, daily kV imaging was performed and the markers were localized and tracked. The change in distance between fiducial markers was analyzed based on the planning CT and daily kV images. Results: Thirty-four patients were simulated at an average of 28 days after surgery, and started the treatment on an average of 39 days after surgery. The average intermarker distance (AiMD) between fiducial markers was strongly correlated to seroma volume. The average reduction in AiMD was 19.1% (range 0.0%-41.4%) and 10.8% (range 0.0%-35.6%) for all the patients between simulation and completion of radiotherapy, and between simulation and beginning of radiotherapy, respectively. The change of AiMD fits an exponential function with a half-life of seroma shrinkage. The average half-life for seroma shrinkage was 15 days. After accounting for the reduction which started to occur after surgery through CT simulation and treatment, radiation was found to have minimal impact on the distance change over the treatment course. Conclusions: Using the marker distance change as a surrogate for seroma volume, it appears that the seroma cavity experiences an exponential reduction in size. The change in seroma size has implications in the size of

  16. Intensity-Modulated Radiotherapy of Pelvic Lymph Nodes in Locally Advanced Prostate Cancer: Planning Procedures and Early Experiences

    SciTech Connect

    Muren, Ludvig Paul Wasbo, Ellen; Helle, Svein Inge; Hysing, Liv Bolstad; Karlsdottir, Asa; Odland, Odd Harald; Valen, Harald; Ekerold, Randi; Johannessen, Dag Clement

    2008-07-15

    Purpose: We present planning and early clinical outcomes of a study of intensity-modulated radiotherapy (IMRT) for locally advanced prostate cancer. Methods and Materials: A total of 43 patients initially treated with an IMRT plan delivering 50 Gy to the prostate, seminal vesicles, and pelvic lymph nodes, followed by a conformal radiotherapy (CRT) plan delivering 20 Gy to the prostate and seminal vesicles, were studied. Dose-volume histogram (DVH) data for the added plans were compared with dose-volume histogram data for the sum of two CRT plans for 15 cases. Gastrointestinal (GI) and genitourinary (GU) toxicity, based on the Radiation Therapy Oncology Group scoring system, was recorded weekly throughout treatment as well as 3 to 18 months after treatment and are presented. Results: Treatment with IMRT both reduced normal tissue doses and increased the minimum target doses. Intestine volumes receiving more than 40 and 50 Gy were significantly reduced (e.g., at 50 Gy, from 81 to 19 cm{sup 3}; p = 0.026), as were bladder volumes above 40, 50, and 60 Gy, rectum volumes above 30, 50, and 60 Gy, and hip joint muscle volumes above 20, 30, and 40 Gy. During treatment, Grade 2 GI toxicity was reported by 12 of 43 patients (28%), and Grade 2 to 4 GU toxicity was also observed among 12 patients (28%). With 6 to 18 months of follow-up, 2 patients (5%) experienced Grade 2 GI effects and 7 patients (16%) experienced Grade 2 GU effects. Conclusions: Use of IMRT for pelvic irradiation in prostate cancer reduces normal tissue doses, improves target coverage, and has a promising toxicity profile.

  17. Intensity-Modulated Radiotherapy Causes Fewer Side Effects than Three-Dimensional Conformal Radiotherapy When Used in Combination With Brachytherapy for the Treatment of Prostate Cancer

    SciTech Connect

    Forsythe, Kevin; Blacksburg, Seth; Stone, Nelson; Stock, Richard G.

    2012-06-01

    Purpose: To measure the benefits of intensity-modulated radiotherapy (IMRT) compared with three-dimensional conformal radiotherapy (3D-CRT) when used in combination with brachytherapy for the treatment of prostate cancer. Methods and Materials: We conducted a retrospective review of all patients with localized prostate cancer who received external-beam radiotherapy (EBRT) in combination with brachytherapy with at least 1 year follow-up (n = 812). Combination therapy consisted of {sup 103}Pd or {sup 125}I implant, followed by a course of EBRT. From 1993 to March 2003 521 patients were treated with 3D-CRT, and from April 2003 to March 2009 291 patients were treated with IMRT. Urinary symptoms were prospectively measured with the International Prostate Symptom Score questionnaire with a single quality of life (QOL) question; rectal bleeding was assessed per the Radiation Therapy Oncology Group/European Organization for Research and Treatment of Cancer Late Radiation Morbidity Scoring Schema. The Pearson {chi}{sup 2} test was used to compare toxicities experienced by patients who were treated with either IMRT or 3D-CRT. Logistic regression analyses were also performed to rule out possible confounding factors. Results: Within the first 3 months after treatment, patients treated with 3D-CRT scored their urinary symptoms as follows: 19% mild, 44% moderate, and 37% severe; patients treated with IMRT scored their urinary symptoms as follows: 36% mild, 47% moderate, and 17% severe (p < 0.001). The 3D-CRT patients rated their QOL as follows: 35% positive, 20% neutral, and 45% negative; IMRT patients rated their QOL as follows: 51% positive, 18% neutral, and 31% negative (p < 0.001). After 1 year of follow-up there was no longer any difference in urinary morbidity between the two groups. Logistic regression confirmed the differences in International Prostate Symptom Score and QOL in the acute setting (p < 0.001 for both). Grade {>=}2 rectal bleeding was reported by 11% of 3D

  18. SU-E-J-254: Utility of Pinnacle Dynamic Planning Module Utilizing Deformable Image Registration in Adaptive Radiotherapy

    SciTech Connect

    Jani, S

    2014-06-01

    Purpose For certain highly conformal treatment techniques, changes in patient anatomy due to weight loss and/or tumor shrinkage can result in significant changes in dose distribution. Recently, the Pinnacle treatment planning system added a Dynamic Planning module utilizing Deformable Image Registration (DIR). The objective of this study was to evaluate the effectiveness of this software in adapting to altered anatomy and adjusting treatment plans to account for it. Methods We simulated significant tumor response by changing patient thickness and altered chin positions using a commercially-available head and neck (H and N) phantom. In addition, we studied 23 CT image sets of fifteen (15) patients with H and N tumors and eight (8) patients with prostate cancer. In each case, we applied deformable image registration through Dynamic Planning module of our Pinnacle Treatment Planning System. The dose distribution of the original CT image set was compared to the newly computed dose without altering any treatment parameter. Result was a dose if we did not adjust the plan to reflect anatomical changes. Results For the H and N phantom, a tumor response of up to 3.5 cm was correctly deformed by the Pinnacle Dynamic module. Recomputed isodose contours on new anatomies were within 1 mm of the expected distribution. The Pinnacle system configuration allowed dose computations resulting from original plans on new anatomies without leaving the planning system. Original and new doses were available side-by-side with both CT image sets. Based on DIR, about 75% of H and N patients (11/15) required a re-plan using new anatomy. Among prostate patients, the DIR predicted near-correct bladder volume in 62% of the patients (5/8). Conclusions The Dynamic Planning module of the Pinnacle system proved to be an accurate and useful tool in our ability to adapt to changes in patient anatomy during a course of radiotherapy.

  19. High-Dose Conformal Radiotherapy Reduces Prostate Cancer-Specific Mortality: Results of a Meta-analysis

    SciTech Connect

    Viani, Gustavo Arruda; Godoi Bernardes da Silva, Lucas; Stefano, Eduardo Jose

    2012-08-01

    Purpose: To determine in a meta-analysis whether prostate cancer-specific mortality (PCSM), biochemical or clinical failure (BCF), and overall mortality (OM) in men with localized prostate cancer treated with conformal high-dose radiotherapy (HDRT) are better than those in men treated with conventional-dose radiotherapy (CDRT). Methods and Materials: The MEDLINE, Embase, CANCERLIT, and Cochrane Library databases, as well as the proceedings of annual meetings, were systematically searched to identify randomized, controlled studies comparing conformal HDRT with CDRT for localized prostate cancer. Results: Five randomized, controlled trials (2508 patients) that met the study criteria were identified. Pooled results from these randomized, controlled trials showed a significant reduction in the incidence of PCSM and BCF rates at 5 years in patients treated with HDRT (p = 0.04 and p < 0.0001, respectively), with an absolute risk reduction (ARR) of PCSM and BCF at 5 years of 1.7% and 12.6%, respectively. Two trials evaluated PCSM with 10 years of follow up. The pooled results from these trials showed a statistical benefit for HDRT in terms of PCSM (p = 0.03). In the subgroup analysis, trials that used androgen deprivation therapy (ADT) showed an ARR for BCF of 12.9% (number needed to treat = 7.7, p < 0.00001), whereas trials without ADT had an ARR of 13.6% (number needed to treat = 7, p < 0.00001). There was no difference in the OM rate at 5 and 10 years (p = 0.99 and p = 0.11, respectively) between the groups receiving HDRT and CDRT. Conclusions: This meta-analysis is the first study to show that HDRT is superior to CDRT in preventing disease progression and prostate cancer-specific death in trials that used conformational technique to increase the total dose. Despite the limitations of our study in evaluating the role of ADT and HDRT, our data show no benefit for HDRT arms in terms of BCF in trials with or without ADT.

  20. Phase II trial of temozolomide and reirradiation using conformal 3D-radiotherapy in recurrent brain gliomas

    PubMed Central

    2014-01-01

    Purpose This phase II trial was designed to assess the response rate, survival benefits and toxicity profile of temozolomide, and brain reirradiation using conformal radiotherapy (RT) for treatment of recurrent high grade glioma. Design Open-label phase II trial. Patients Twenty-nine patients had been enrolled in the study between February 2006 and June 2009. Patients had to show unequivocal evidence of tumour recurrence on gadolinium-enhanced magnetic resonance imaging (MRI) after failing conventional RT with or without temozolomide and surgery for initial disease. Histology included recurrent anaplastic astrocytoma, glioblastoma multiforme. Interventions Patients were treated by temozolomide at a dose of 200 mg/m2/day for chemonaïve patients, and at a dose of 150 mg/m2/day to previously treated patients, for 4-5 cycles. Then, patients underwent reirradiation by conformal RT at a dose of 30-40 Gy by conventional fractionation. Main outcome measures The primary end point of the study was response. The secondary end points included survival benefit. Results All the 29 patients were treated with temozolomide and reirradiation. Two patients achieved complete remission (CR), 4 achieved partial remission (PR), with an overall objective response rate of 20.6%, and further 10 patients had stable disease (SD), with a SD rate of 34.4%. The mean progression free survival (PFS) was 10.1 months, and the mean overall survival (OS) was 11.4 months. Additionally, treatment significantly improved quality of life (QOL). Treatment was tolerated well with mild grade 1, 2 nausea/vomiting in 40% of cycles, and mild grade 1, 2 haematological toxicities (neutropenia/thrombocytoprnia) in 8.6% of cycles. Conclusions Temozolomide and conformal RT had an anti-tumor activity in recurrent high grade glioma, and represented a good treatment hope for patients with recurrent brain glioma. PMID:25333019

  1. SU-E-T-538: Lung SBRT Dosimetric Comparison of 3D Conformal and RapidArc Planning

    SciTech Connect

    Jiang, R; Zhan, L; Osei, E

    2015-06-15

    Purpose: Dose distributions of RapidArc Plan can be quite different from standard 3D conformal radiation therapy. SBRT plans can be optimized with high conformity or mimic the 3D conformal treatment planning with very high dose in the center of the tumor. This study quantifies the dosimetric differences among 3D conformal plan; flattened beam and FFF beam RapidArc Plans for lung SBRT. Methods: Five lung cancer patients treated with 3D non-coplanar SBRT were randomly selected. All the patients were CT scanned with 4DCT to determine the internal target volume. Abdominal compression was applied to minimize respiratory motion for SBRT patients. The prescription dose was 48 Gy in 4 fractions. The PTV coverage was optimized by two groups of objective function: one with high conformity, another mimicking 3D conformal dose distribution with high dose in the center of PTV. Optimization constraints were set to meet the criteria of the RTOG-0915 protocol. All VMAT plans were optimized with the RapidArc technique using four full arcs in Eclipse treatment planning system. The RapidArc SBRT plans with flattened 6MV beam and 6MV FFF beam were generated and dosimetric results were compared with the previous treated 3D non-coplanar plans. Results: All the RapidArc plans with flattened beam and FFF beam had similar results for the PTV and OARs. For the high conformity optimization group, The DVH of PTV exhibited a steep dose fall-off outside the PTV compared to the 3D non-coplanar plan. However, for the group mimicking the 3D conformal target dose distribution, although the PTV is very similar to the 3D conformal plan, the ITV coverage is better than 3D conformal plan. Conclusion: Due to excellent clinical experiences of 3D conformal SBRT treatment, the Rapid Arc optimization mimicking 3D conformal planning may be suggested for clinical use.

  2. Sci—Thur PM: Planning and Delivery — 02: Treatment planning workflow for very high-energy electron beam radiotherapy

    SciTech Connect

    Bazalova, Magdalena; Qu, Bradley; Palma, Bianey; Maxim, Peter; Loo, Billy; Hårdemark, Bjorn; Hynning, Elin

    2014-08-15

    Purpose: To develop treatment planning workflow for rapid radiotherapy delivered with very-high energy electron (VHEE) scanning beam. Methods: VHEE radiotherapy treatment planning was performed by linking Monte Carlo (MC) dose calculations with inverse optimization in a research version of RayStation. In order to study a number of treatment parameters, a Matlab graphical user interface (GUI) for calculation of VHEE beamlet dose was developed. Through the GUI, EGSnrc MC simulations were run for a number of beam energies, number of beams, beamlet spot and grid sizes, and machine bore sizes. VHEE plans for a pediatric patient with a 4.3 cm{sup 3} brain target optimized with spot-scanning algorithm in RayStation were compared to the clinically delivered 6 MV VMAT plan. Results and Discussion: VHEE beam energy had the largest effect on the quality of dose distributions. For the same target dose, the mean doses to critical organs decreased by 10–15% when planned with 100 MeV compared to 60 MeV. VHEE plans calculated with 36 beams outperformed plans calculated with 13 and 17 beams. While beamlet spacing and bore size had a small effect on VHEE dose distributions, 0.1-3mm beamlet sizes resulted in identical dose distributions. Critical organ doses were by up to 70% lower in the best VHEE plan compared to the clinical 6 MV VMAT plan. Conclusions: We have developed a GUI for MC beamlet generation for treatment planning of VHEE radiotherapy. We have demonstrated that pediatric VHEE plans resulted in significant critical organ dose sparing compared to the clinical VMAT plan.

  3. Equivalent Biochemical Control and Improved Prostate-Specific Antigen Nadir After Permanent Prostate Seed Implant Brachytherapy Versus High-Dose Three-Dimensional Conformal Radiotherapy and High-Dose Conformal Proton Beam Radiotherapy Boost

    SciTech Connect

    Jabbari, Siavash; Weinberg, Vivian K.; Shinohara, Katsuto; Speight, Joycelyn L.; Gottschalk, Alexander R.; Hsu, I.-C.; Pickett, Barby; McLaughlin, Patrick W.; Sandler, Howard M.; Roach, Mack

    2010-01-15

    Purpose: Permanent prostate implant brachytherapy (PPI), three-dimensional conformal radiotherapy (3D-CRT), and conformal proton beam radiotherapy (CPBRT) are used in the treatment of localized prostate cancer, although no head-to-head trials have compared these modalities. We studied the biochemical control (biochemical no evidence of disease [bNED]) and prostate-specific antigen (PSA) nadir achieved with contemporary PPI, and evaluated it against 3D-CRT and CPBRT. Patients and Methods: A total of 249 patients were treated with PPI at the University of California, San Francisco, and the outcomes were compared with those from a 3D-CRT cohort and the published results of a high-dose CPBRT boost (CPBRTB) trial. For each comparison, subsets of the PPI cohort were selected with patient and disease criteria similar to those of the reference group. Results: With a median follow-up of 5.3 years, the bNED rate at 5 and 7 years achieved with PPI was 92% and 86%, respectively, using the American Society for Therapeutic Radiology and Oncology (ASTRO) definition, and 93% using the PSA nadir plus 2 ng/mL definition. Using the ASTRO definition, a 5-year bNED rate of 78% was achieved for the 3D-CRT patients compared with 94% for a comparable PPI subset and 93% vs. 92%, respectively, using the PSA nadir plus 2 ng/mL definition. The median PSA nadir for patients treated with PPI and 3D-CRT was 0.10 and 0.40 ng/mL, respectively (p < .0001). For the CPBRT comparison, the 5-year bNED rate after a CPBRTB was 91% using the ASTRO definition vs. 93% for a similar group of PPI patients. A greater proportion of PPI patients achieved a lower PSA nadir compared with those achieved in the CPBRTB trial (PSA nadir <=0.5 ng/mL, 91% vs. 59%, respectively). Conclusion: We have demonstrated excellent outcomes in low- to intermediate-risk patients treated with PPI, suggesting at least equivalent 5-year bNED rates and a greater proportion of men achieving lower PSA nadirs compared with 3D-CRT or

  4. Three-dimensional conformal radiotherapy for locally advanced (Stage II and worse) head-and-neck cancer: Dosimetric and clinical evaluation

    SciTech Connect

    Portaluri, Maurizio . E-mail: portaluri@hotmail.com; Fucilli, Fulvio I.M.; Castagna, Roberta; Bambace, Santa; Pili, Giorgio; Tramacere, Francesco; Russo, Donatella; Francavilla, Maria Carmen

    2006-11-15

    Purpose: To evaluate the dosimetric parameters of three-dimensional conformal radiotherapy (3D-CRT) in locally advanced head-and-neck tumors (Stage II and above) and the effects on xerostomia. Methods and Materials: A total of 49 patients with histologically proven squamous cell cancer of the head and neck were consecutively treated with 3D-CRT using a one-point setup technique; 17 had larynx cancer, 12 oropharynx, 12 oral cavity, and 6 nasopharynx cancer; 2 had other sites of cancer. Of the 49 patients, 41 received postoperative RT and 8 definitive treatment. Also, 13 were treated with cisplatin-based chemotherapy before and during RT; in 6 cases, 5-fluorouracil was added. The follow-up time was 484-567 days (median, 530 days). Results: One-point setup can deliver 96% of the prescribed dose to the isocenter, to the whole planning target volume, including all node levels of the neck and without overdosages. The mean dose to the primary planning target volume was 49.54 {+-} 4.82 Gy (51.53 {+-} 5.47 Gy for larynx cases). The average dose to the contralateral parotid gland was approximately 38 Gy (30 Gy for larynx cases). The maximal dose to the spinal cord was 46 Gy. A Grade 0 Radiation Therapy Oncology Group/European Organization for Research and Treatment of Cancer xerostomia score corresponded to a mean dose of 30 Gy to one parotid gland. A lower xerostomia score with a lower mean parotid dose and longer follow-up seemed to give rise to a sort of functional recovery phenomenon. Conclusion: Three dimensional-CRT in head-and-neck cancers permits good coverage of the planning target volume with about 10-11 segments and one isocenter. With a mean dose of approximately 30 Gy to the contralateral parotid, we observed no or mild xerostomia.

  5. A Dosimetric Comparison of Accelerated Partial Breast Irradiation Techniques: Multicatheter Interstitial Brachytherapy, Three-Dimensional Conformal Radiotherapy, and Supine Versus Prone Helical Tomotherapy

    SciTech Connect

    Patel, Rakesh R. . E-mail: patel@humonc.wisc.edu; Becker, Stewart J.; Das, Rupak K.; Mackie, Thomas R.

    2007-07-01

    Purpose: To compare dosimetrically four different techniques of accelerated partial breast irradiation (APBI) in the same patient. Methods and Materials: Thirteen post-lumpectomy interstitial brachytherapy (IB) patients underwent imaging with preimplant computed tomography (CT) in the prone and supine position. These CT scans were then used to generate three-dimensional conformal radiotherapy (3D-CRT) and prone and supine helical tomotherapy (PT and ST, respectively) APBI plans and compared with the treated IB plans. Dose-volume histogram analysis and the mean dose (NTD{sub mean}) values were compared. Results: Planning target volume coverage was excellent for all methods. Statistical significance was considered to be a p value <0.05. The mean V100 was significantly lower for IB (12% vs. 15% for PT, 18% for ST, and 26% for 3D-CRT). A greater significant differential was seen when comparing V50 with mean values of 24%, 43%, 47%, and 52% for IB, PT, ST, and 3D-CRT, respectively. The IB and PT were similar and delivered an average lung NTD{sub mean} dose of 1.3 Gy{sub 3} and 1.2 Gy{sub 3}, respectively. Both of these methods were statistically significantly lower than the supine external beam techniques. Overall, all four methods yielded similar low doses to the heart. Conclusions: The use of IB and PT resulted in greater normal tissue sparing (especially ipsilateral breast and lung) than the use of supine external beam techniques of 3D-CRT or ST. However, the choice of APBI technique must be tailored to the patient's anatomy, lumpectomy cavity location, and overall treatment goals.

  6. Role of Systemic Therapy in the Development of Lung Sequelae After Conformal Radiotherapy in Breast Cancer Patients

    SciTech Connect

    Varga, Zoltan; Cserhati, Adrienn; Kelemen, Gyoengyi; Boda, Krisztina; Thurzo, Laszlo; Kahan, Zsuzsanna

    2011-07-15

    Purpose: To analyze the risk of radiogenic lung damage in breast cancer patients after conformal radiotherapy and different forms of systemic treatment. Methods and Materials: In 328 patients receiving sequential taxane-based chemotherapy, concomitant hormone therapy (tamoxifen or aromatase inhibitors), or no adjuvant systemic therapy, symptomatic and asymptomatic lung sequelae were prospectively evaluated via the detection of visible CT abnormalities, 3 months or 1 year after the completion of the radiotherapy. Results: Significant positive associations were detected between the development of both pneumonitis and fibrosis of Grade 1 and patient age, ipsilateral mean lung dose, volume of the ipsilateral lung receiving 20 Gy, and irradiation of the regional lymph nodes. In multivariate analysis, age and mean lung dose proved to be independent predictors of early (odds ratio [OR] = 1.035, 95% confidence interval [CI] 1.011-1.061 and OR = 1.113, 95% CI 1.049-1.181, respectively) and late (OR = 1.074, 95% CI 1.042-1.107 and OR = 1.207, 95% CI 1.124-1.295, respectively) radiogenic lung damage, whereas the role of systemic therapy was significant in the development of Grade 1 lung fibrosis (p = 0.01). Among the various forms of systemic therapy, tamoxifen increased the risk of late lung sequelae (OR = 2.442, 95% CI 1.120-5.326, p = 0.025). No interaction was demonstrated between the administration of systemic therapy and the other above-mentioned parameters as regards the risk of radiogenic lung damage. Conclusions: Our analyses demonstrate the independent role of concomitant tamoxifen therapy in the development of radiogenic lung fibrosis but do not suggest such an effect for the other modes of systemic treatment.

  7. Outcome After Conformal Salvage Radiotherapy in Patients With Rising Prostate-Specific Antigen Levels After Radical Prostatectomy

    SciTech Connect

    Geinitz, Hans; Riegel, Martina G.; Thamm, Reinhard; Astner, Sabrina T.; Lewerenz, Carolin; Zimmermann, Frank; Molls, Michael; Nieder, Carsten

    2012-04-01

    Purpose: This study attempts to improve our understanding of the role of salvage radiotherapy (SRT) in patients with prostate-specific antigen (PSA) relapse after radical prostatectomy with regard to biochemical control, rate of distant metastasis, and survival. Methods and Materials: We performed a retrospective analysis of 96 men treated with conformal prostate bed SRT (median, 64.8 Gy) at a single institution (median follow-up, 70 months). The majority had intermediate- or high-risk prostate cancer. Fifty-four percent underwent a resection with positive margins (R1 resection). The median time interval between surgery and SRT was 22 months. Results: After SRT, 66% of patients reached a PSA nadir of less than 0.2 ng/mL. However, the 5-year biochemical no evidence of disease rate was 35%. Seminal vesicle involvement was predictive for a significantly lower biochemical no evidence of disease rate. All patients with a preoperative PSA level greater than 50 ng/mL relapsed biochemically within 2 years. The 5-year distant metastasis rate was 18%, the 5-year prostate cancer-specific survival rate was 90%, and the 5-year overall survival rate was 88%. Significantly more distant metastases developed in patients with a PSA nadir greater than 0.05 ng/mL after SRT, and they had significantly inferior prostate cancer-specific and overall survival rates. Resection status (R1 vs. R0) was not predictive for any of the endpoints. Conclusions: Men with postoperative PSA relapse can undergo salvage treatment by prostate bed radiotherapy, but durable PSA control is maintained only in about one-third of the patients. Despite a high biochemical failure rate after SRT, prostate cancer-specific survival does not decrease rapidly.

  8. Treating benign optic nerve tumors with a 3-D conformal plan

    SciTech Connect

    Millunchick, Cheryl Hope

    2013-07-01

    A 68 year old male patient presented for radiation therapy for treatment of a benign tumor, a glioma of his left optic nerve. The radiation oncologist intended to prescribe 52.2 Gy to the planning target volume, while maintaining a maximum of 54 Gy to the optic nerves and the optic chiasm and a maximum of 40–45 Gy to the globes in order to minimize the possibility of damaging the optic system, which is especially important as this is a benign tumor. The dosimetrist devised a conformal non-coplanar three-dimensional plan with a slightly weighted forward planning component. This plan was created in approximately 15 minutes after the critical organs and the targets were delineated and resulted in an extremely conformal and homogenous plan, treating the target while sparing the nearby critical structures. This approach can also be extended to other tumors in the brain - benign or malignant.

  9. Quality assessment for VMAT prostate radiotherapy planning based on data envelopment analysis

    NASA Astrophysics Data System (ADS)

    Lin, Kuan-Min; Simpson, John; Sasso, Giuseppe; Raith, Andrea; Ehrgott, Matthias

    2013-08-01

    The majority of commercial radiotherapy treatment planning systems requires planners to iteratively adjust the plan parameters in order to find a satisfactory plan. This iterative trial-and-error nature of radiotherapy treatment planning results in an inefficient planning process and in order to reduce such inefficiency, plans can be accepted without achieving the best attainable quality. We propose a quality assessment method based on data envelopment analysis (DEA) to address this inefficiency. This method compares a plan of interest to a set of past delivered plans and searches for evidence of potential further improvement. With the assistance of DEA, planners will be able to make informed decisions on whether further planning is required and ensure that a plan is only accepted when the plan quality is close to the best attainable one. We apply the DEA method to 37 prostate plans using two assessment parameters: rectal generalized equivalent uniform dose (gEUD) as the input and D95 (the minimum dose that is received by 95% volume of a structure) of the planning target volume (PTV) as the output. The percentage volume of rectum overlapping PTV is used to account for anatomical variations between patients and is included in the model as a non-discretionary output variable. Five plans that are considered of lesser quality by DEA are re-optimized with the goal to further improve rectal sparing. After re-optimization, all five plans improve in rectal gEUD without clinically considerable deterioration of the PTV D95 value. For the five re-optimized plans, the rectal gEUD is reduced by an average of 1.84 Gray (Gy) with only an average reduction of 0.07 Gy in PTV D95. The results demonstrate that DEA can correctly identify plans with potential improvements in terms of the chosen input and outputs.

  10. Feasibility of using intermediate x-ray energies for highly conformal extracranial radiotherapy

    SciTech Connect

    Dong, Peng; Yu, Victoria; Nguyen, Dan; Demarco, John; Low, Daniel A.; Sheng, Ke; Woods, Kaley; Boucher, Salime

    2014-04-15

    Purpose: To investigate the feasibility of using intermediate energy 2 MV x-rays for extracranial robotic intensity modulated radiation therapy. Methods: Two megavolts flattening filter free x-rays were simulated using the Monte Carlo code MCNP (v4c). A convolution/superposition dose calculation program was tuned to match the Monte Carlo calculation. The modeled 2 MV x-rays and actual 6 MV flattened x-rays from existing Varian Linacs were used in integrated beam orientation and fluence optimization for a head and neck, a liver, a lung, and a partial breast treatment. A column generation algorithm was used for the intensity modulation and beam orientation optimization. Identical optimization parameters were applied in three different planning modes for each site: 2, 6 MV, and dual energy 2/6 MV. Results: Excellent agreement was observed between the convolution/superposition and the Monte Carlo calculated percent depth dose profiles. For the patient plans, overall, the 2/6 MV x-ray plans had the best dosimetry followed by 2 MV only and 6 MV only plans. Between the two single energy plans, the PTV coverage was equivalent but 2 MV x-rays improved organs-at-risk sparing. For the head and neck case, the 2MV plan reduced lips, mandible, tongue, oral cavity, brain, larynx, left and right parotid gland mean doses by 14%, 8%, 4%, 14%, 24%, 6%, 30% and 16%, respectively. For the liver case, the 2 MV plan reduced the liver and body mean doses by 17% and 18%, respectively. For the lung case, lung V20, V10, and V5 were reduced by 13%, 25%, and 30%, respectively. V10 of heart with 2 MV plan was reduced by 59%. For the partial breast treatment, the 2 MV plan reduced the mean dose to the ipsilateral and contralateral lungs by 27% and 47%, respectively. The mean body dose was reduced by 16%. Conclusions: The authors showed the feasibility of using flattening filter free 2 MV x-rays for extracranial treatments as evidenced by equivalent or superior dosimetry compared to 6 MV plans

  11. Automated planning of breast radiotherapy using cone beam CT imaging

    SciTech Connect

    Amit, Guy; Purdie, Thomas G.

    2015-02-15

    Purpose: Develop and clinically validate a methodology for using cone beam computed tomography (CBCT) imaging in an automated treatment planning framework for breast IMRT. Methods: A technique for intensity correction of CBCT images was developed and evaluated. The technique is based on histogram matching of CBCT image sets, using information from “similar” planning CT image sets from a database of paired CBCT and CT image sets (n = 38). Automated treatment plans were generated for a testing subset (n = 15) on the planning CT and the corrected CBCT. The plans generated on the corrected CBCT were compared to the CT-based plans in terms of beam parameters, dosimetric indices, and dose distributions. Results: The corrected CBCT images showed considerable similarity to their corresponding planning CTs (average mutual information 1.0±0.1, average sum of absolute differences 185 ± 38). The automated CBCT-based plans were clinically acceptable, as well as equivalent to the CT-based plans with average gantry angle difference of 0.99°±1.1°, target volume overlap index (Dice) of 0.89±0.04 although with slightly higher maximum target doses (4482±90 vs 4560±84, P < 0.05). Gamma index analysis (3%, 3 mm) showed that the CBCT-based plans had the same dose distribution as plans calculated with the same beams on the registered planning CTs (average gamma index 0.12±0.04, gamma <1 in 99.4%±0.3%). Conclusions: The proposed method demonstrates the potential for a clinically feasible and efficient online adaptive breast IMRT planning method based on CBCT imaging, integrating automation.

  12. Patient-specific dosimetric endpoints based treatment plan quality control in radiotherapy

    NASA Astrophysics Data System (ADS)

    Song, Ting; Staub, David; Chen, Mingli; Lu, Weiguo; Tian, Zhen; Jia, Xun; Li, Yongbao; Zhou, Linghong; Jiang, Steve B.; Gu, Xuejun

    2015-11-01

    In intensity modulated radiotherapy (IMRT), the optimal plan for each patient is specific due to unique patient anatomy. To achieve such a plan, patient-specific dosimetric goals reflecting each patient’s unique anatomy should be defined and adopted in the treatment planning procedure for plan quality control. This study is to develop such a personalized treatment plan quality control tool by predicting patient-specific dosimetric endpoints (DEs). The incorporation of patient specific DEs is realized by a multi-OAR geometry-dosimetry model, capable of predicting optimal DEs based on the individual patient’s geometry. The overall quality of a treatment plan is then judged with a numerical treatment plan quality indicator and characterized as optimal or suboptimal. Taking advantage of clinically available prostate volumetric modulated arc therapy (VMAT) treatment plans, we built and evaluated our proposed plan quality control tool. Using our developed tool, six of twenty evaluated plans were identified as sub-optimal plans. After plan re-optimization, these suboptimal plans achieved better OAR dose sparing without sacrificing the PTV coverage, and the dosimetric endpoints of the re-optimized plans agreed well with the model predicted values, which validate the predictability of the proposed tool. In conclusion, the developed tool is able to accurately predict optimally achievable DEs of multiple OARs, identify suboptimal plans, and guide plan optimization. It is a useful tool for achieving patient-specific treatment plan quality control.

  13. Dosimetric comparison of different multileaf collimator leaves in treatment planning of intensity-modulated radiotherapy for cervical cancer

    SciTech Connect

    Wang, Shichao; Ai, Ping; Xie, Li; Xu, Qingfeng; Bai, Sen; Lu, You; Li, Ping; Chen, Nianyong

    2013-01-01

    To study the effect of multileaf collimator (MLC) leaf widths (standard MLC [sMLC] width of 10 mm and micro-MLC [mMLC] width of 4 mm) on intensity-modulated radiotherapy (IMRT) for cervical cancer. Between January 2010 and August 2010, a retrospective analysis was conducted on 12 patients with cervical cancer. The treatment plans for all patients were generated with the same machine setup parameters and optimization methods in a treatment planning system (TPS) based on 2 commercial Elekta MLC devices. The dose distribution for the planning tumor volume (PTV), the dose sparing for organs at risk (OARs), the monitor units (MUs), and the number of IMRT segments were evaluated. For the delivery efficiency, the MUs were significantly higher in the sMLC-IMRT plan than in the mMLC-IMRT plan (802 ± 56.9 vs 702 ± 56.7; p < 0.05). The number of segments in the plans were 58.75 ± 1.8 and 59 ± 1.04 (p > 0.05). For the planning quality, the conformity index (CI) between the 2 paired IMRT plans with the mMLC and the sMLC did not differ significantly (average: 0.817 ± 0.024 vs 0.810 ± 0.028; p > 0.05). The differences of the homogeneity index (HI) between the 2 paired plans were statistically significant (average: 1.122 ± 0.010 vs 1.132 ± 0.014; p < 0.01). For OARs, the rectum, bladder, small intestine, and bony pelvis were evaluated in terms of V{sub 10}, V{sub 20}, V{sub 30}, and V{sub 40}, percentage of contoured OAR volumes receiving 10, 20, 30, and 40 Gy, respectively, and the mean dose (D{sub mean}) received. The IMRT plans with the mMLC protected the OARs better than the plans with the sMLC. There were significant differences (p < 0.05) in evaluated parameters between the 2 paired IMRT plans, except for V{sub 30} and V{sub 40} of the rectum and V{sub 10}, V{sub 20}, V{sub 40}, and D{sub mean} of the bladder. IMRT plans with the mMLC showed advantages over the plans with the sMLC in dose homogeneity for targets, dose sparing of OARs, and fewer MUs in cervical cancer.

  14. Health-Related Quality of Life in Patients With Locally Advanced Prostate Cancer After 76 Gy Intensity-Modulated Radiotherapy vs. 70 Gy Conformal Radiotherapy in a Prospective and Longitudinal Study

    SciTech Connect

    Lips, Irene Dehnad, Human; Kruger, Arto Boeken; Moorselaar, Jeroen van; Heide, Uulke van; Battermann, Jan; Vulpen, Marco van

    2007-11-01

    Purpose: To compare quality of life (QoL) after 70 Gy conformal radiotherapy with QoL after 76 Gy intensity-modulated radiotherapy (IMRT) in patients with locally advanced prostate carcinoma. Methods and Materials: Seventy-eight patients with locally advanced prostate cancer were treated with 70 Gy three-field conformal radiotherapy, and 92 patients received 76 Gy IMRT with fiducial markers for position verification. Quality of life was measured by RAND-36, the European Organization for Research and Treatment of Cancer core questionnaire (EORTC QLQ-C30(+3)), and the prostate-specific EORTC QLQ-PR25, before radiotherapy (baseline) and 1 month and 6 months after treatment. Quality of life changes in time (baseline vs. 1 month and baseline vs. 6 months) of {>=}10 points were considered clinically relevant. Results: Differences between the treatment groups for QoL changes over time occurred in several QoL domains. The 76-Gy group revealed no significant deterioration in QoL compared with the 70-Gy group. The IMRT 76-Gy group even demonstrated a significantly better change in QoL from baseline to 1 month in several domains. The conformal 70-Gy group revealed temporary deterioration in pain, role functioning, and urinary symptoms; for the IMRT 76-Gy group a better QoL in terms of change in health existed after 1 month, which persisted after 6 months. For both treatment groups temporary deterioration in physical role restriction occurred after 1 month, and an improvement in emotional role restriction occurred after 6 months. Sexual activity was reduced after treatment for both groups and remained decreased after 6 months. Conclusions: Intensity-modulated radiotherapy and accurate position verification seem to provide a possibility to increase the radiation dose for prostate cancer without deterioration in QoL.

  15. Sexual Function After Three-Dimensional Conformal Radiotherapy for Prostate Cancer: Results From a Dose-Escalation Trial

    SciTech Connect

    Wielen, Gerard J. van der . E-mail: g.vanderwielen@erasmusmc.nl; Putten, Wim van; Incrocci, Luca

    2007-06-01

    Purpose: The purpose of this study is to provide information about sexual function (SF) after three-dimensional conformal radiotherapy (3D-CRT) for prostate cancer while taking important factors into account that influence SF. Methods and Materials: Between June 1997 and February 2003, a total of 268 patients from a randomized dose-escalation trial comparing 68 Gy and 78 Gy agreed to participate in an additional part of the trial that evaluated SF. Results: At baseline 28% of patients had erectile dysfunction (ED). After 1 year, 27% of the pretreatment potent patients had developed ED. After 2 years this percentage had increased to 36%. After 3 years it almost stabilized at 38%. Satisfaction with sexual life was significantly correlated with ED. After 2 years one third of the pre-treatment potent patients still had considerable to very much sexual desire and found sex (very) important. No significant differences were found between the two dose-arms. Potency aids were used on a regular base by 14% of the patients. Conclusion: By taking adjuvant hormonal therapy (HT), HT during follow-up and potency aids into account, we found a lower percentage of ED after 3D-CRT than reported in previous prospective studies. A large group of patients still had sexual desire, considered sex important and 14% used potency aids after 3D-CRT.

  16. Treatment planning considerations in contrast-enhanced radiotherapy: energy and beam aperture optimization.

    PubMed

    Garnica-Garza, H M

    2011-01-21

    It has been shown that the use of kilovoltage x-rays in conjunction with a contrast agent incorporated into the tumor can lead to acceptable treatment plans with regard to the absorbed dose distribution produced in the target as well as in the tissue and organs at risk surrounding it. In this work, several key aspects related to the technology and irradiation techniques necessary to clinically implement this treatment modality are addressed by means of Monte Carlo simulation. The Zubal phantom was used to model a prostate radiotherapy treatment, a challenging site due to the depth of the prostate and the presence of bony structures that must be traversed by the x-ray beam on its way to the target. It is assumed that the concentration levels of the enhancing agent present in the tumor are at or below 10 mg per 1 g of tissue. The Monte Carlo code PENELOPE was used to model a commercial x-ray tube having a tungsten target. X-ray energy spectra for several combinations of peak electron energy and added filtration were obtained. For each energy spectrum, a treatment plan was calculated, with the PENELOPE Monte Carlo code, by modeling the irradiation of the patient as 72 independent conformal beams distributed at intervals of 5° around the phantom in order to model a full x-ray source rotation. The Cimmino optimization algorithm was then used to find the optimum beam weight and energy for different treatment strategies. It is shown that for a target dose prescription of 72 Gy covering the whole tumor, the maximum rectal wall and bladder doses are kept below 52 Gy for the largest concentration of contrast agent of 10 mg per 1 g of tissue. It is also shown that concentrations of as little as 5 mg per 1 g of tissue also render dose distributions with excellent sparing of the organs at risk. A treatment strategy to address the presence of non-uniform distributions of the contrast agent in the target is also modeled and discussed. PMID:21160112

  17. Treatment planning considerations in contrast-enhanced radiotherapy: energy and beam aperture optimization

    NASA Astrophysics Data System (ADS)

    Garnica-Garza, H. M.

    2011-01-01

    It has been shown that the use of kilovoltage x-rays in conjunction with a contrast agent incorporated into the tumor can lead to acceptable treatment plans with regard to the absorbed dose distribution produced in the target as well as in the tissue and organs at risk surrounding it. In this work, several key aspects related to the technology and irradiation techniques necessary to clinically implement this treatment modality are addressed by means of Monte Carlo simulation. The Zubal phantom was used to model a prostate radiotherapy treatment, a challenging site due to the depth of the prostate and the presence of bony structures that must be traversed by the x-ray beam on its way to the target. It is assumed that the concentration levels of the enhancing agent present in the tumor are at or below 10 mg per 1 g of tissue. The Monte Carlo code PENELOPE was used to model a commercial x-ray tube having a tungsten target. X-ray energy spectra for several combinations of peak electron energy and added filtration were obtained. For each energy spectrum, a treatment plan was calculated, with the PENELOPE Monte Carlo code, by modeling the irradiation of the patient as 72 independent conformal beams distributed at intervals of 5° around the phantom in order to model a full x-ray source rotation. The Cimmino optimization algorithm was then used to find the optimum beam weight and energy for different treatment strategies. It is shown that for a target dose prescription of 72 Gy covering the whole tumor, the maximum rectal wall and bladder doses are kept below 52 Gy for the largest concentration of contrast agent of 10 mg per 1 g of tissue. It is also shown that concentrations of as little as 5 mg per 1 g of tissue also render dose distributions with excellent sparing of the organs at risk. A treatment strategy to address the presence of non-uniform distributions of the contrast agent in the target is also modeled and discussed.

  18. Conformal Postoperative Radiotherapy in Patients With Positive Resection Margins and/or pT3-4 Prostate Adenocarcinoma

    SciTech Connect

    Bellavita, Rita; Massetti, Michela; Abraha, Iosief; Lupattelli, Marco; Mearini, Luigi; Falcinelli, Lorenzo; Farneti, Alessia; Palumbo, Isabella; Porena, Massimo; Aristei, Cynthia

    2012-11-01

    Purpose: To evaluate outcome and toxicity of high-dose conformal radiotherapy (RT) after radical prostatectomy. Methods and Materials: Between August 1998 and December 2007, 182 consecutive patients with positive resection margins and/or pT3-4, node-negative prostate adenocarcinoma underwent postoperative conformal RT. The prescribed median dose to the prostate/seminal vesicle bed was 66.6 Gy (range 50-70). Hormone therapy (a luteinizing hormone-releasing hormone analogue and/or antiandrogen) was administered to 110/182 (60.5%) patients with high-risk features. Biochemical relapse was defined as an increase of more than 0.2 ng/mL over the lowest postoperative prostate-specific antigen (PSA) value measured on 3 occasions, each at least 2 weeks apart. Results: Median follow-up was 55.6 months (range 7.6-141.9 months). The 3- and 5-year probability of biochemical relapse-free survival were 87% and 81%, respectively. In univariate analysis, more advanced T stages, preoperative PSA values {>=}10 ng/mL, and RT doses <70 Gy were significant factors for biochemical relapse. Pre-RT PSA values >0.2 ng/mL were significant for distant metastases. In multivariate analysis, risk factors for biochemical relapse were higher preoperative and pre-RT PSA values, hormone therapy for under 402 days and RT doses of <70 Gy. Higher pre-RT PSA values were the only independent predictor of distant metastases. Acute genitourinary (GU) and gastrointestinal (GI) toxicities occurred in 72 (39.6%) and 91 (50%) patients, respectively. There were 2 cases of Grade III GI toxicity but no cases of Grade IV. Late GU and GI toxicities occurred in 28 (15.4%) and 14 (7.7%) patients, respectively: 11 cases of Grade III toxicity: 1 GI (anal stenosis) and 10 GU, all urethral strictures requiring endoscopic urethrotomy. Conclusions: Postoperative high-dose conformal RT in patients with high-risk features was associated with a low risk of biochemical relapse as well as minimal morbidity.

  19. Computer-assisted targeted therapy (CATT) for prostate radiotherapy planning by fusion of CT and MRI

    NASA Astrophysics Data System (ADS)

    Chappelow, Jonathan; Both, Stefan; Viswanath, Satish; Hahn, Stephen; Feldman, Michael; Rosen, Mark; Tomaszewski, John; Vapiwala, Neha; Patel, Pratik; Madabhushi, Anant

    2010-02-01

    In this paper, we present a comprehensive, quantitative imaging framework for improved treatment of prostate cancer via computer-assisted targeted therapy (CATT) to facilitate radiotherapy dose escalation to regions with a high likelihood of disease presence. The framework involves identification of high likelihood prostate cancer regions using computer-aided detection (CAD) classifier on diagnostic MRI, followed by mapping of these regions from MRI onto planning computerized tomography (CT) via image registration. Treatment of prostate cancer by targeted radiotherapy requires CT to formulate a dose plan. While accurate delineation of the prostate and cancer can provide reduced exposure of benign tissue to radiation, as well as a higher dose to the cancer, CT is ineffective in localizing intraprostatic lesions and poor for highlighting the prostate boundary. MR imagery on the other hand allows for greatly improved visualization of the prostate. Further, several studies have demonstrated the utility of CAD for identifying the location of tumors on in vivo multi-functional prostate MRI. Consequently, our objective is to improve the accuracy of radiotherapy dose plans via multimodal fusion of MR and CT. To achieve this objective, the CATT framework presented in this paper comprises the following components: (1) an unsupervised pixel-wise classifier to identify suspicious regions within the prostate on diagnostic MRI, (2) elastic image registration to align corresponding diagnostic MRI, planning MRI, and CT of the prostate, (3) mapping of the suspect regions from diagnostic MRI onto CT, and (4) calculation of a modified radiotherapy plan with escalated dose for cancer. Qualitative comparison of the dose plans (with and without CAD) over a total of 79 2D slices obtained from 10 MR-CT patient studies, suggest that our CATT framework could help in improved targeted treatment of prostate cancer.

  20. Australasian Gastrointestinal Trials Group (AGITG) Contouring Atlas and Planning Guidelines for Intensity-Modulated Radiotherapy in Anal Cancer

    SciTech Connect

    Ng, Michael; Leong, Trevor; Chander, Sarat; Chu, Julie; Kneebone, Andrew; Carroll, Susan; Wiltshire, Kirsty; Ngan, Samuel; Kachnic, Lisa

    2012-08-01

    Purpose: To develop a high-resolution target volume atlas with intensity-modulated radiotherapy (IMRT) planning guidelines for the conformal treatment of anal cancer. Methods and Materials: A draft contouring atlas and planning guidelines for anal cancer IMRT were prepared at the Australasian Gastrointestinal Trials Group (AGITG) annual meeting in September 2010. An expert panel of radiation oncologists contoured an anal cancer case to generate discussion on recommendations regarding target definition for gross disease, elective nodal volumes, and organs at risk (OARs). Clinical target volume (CTV) and planning target volume (PTV) margins, dose fractionation, and other IMRT-specific issues were also addressed. A steering committee produced the final consensus guidelines. Results: Detailed contouring and planning guidelines and a high-resolution atlas are provided. Gross tumor and elective target volumes are described and pictorially depicted. All elective regions should be routinely contoured for all disease stages, with the possible exception of the inguinal and high pelvic nodes for select, early-stage T1N0. A 20-mm CTV margin for the primary, 10- to 20-mm CTV margin for involved nodes and a 7-mm CTV margin for the elective pelvic nodal groups are recommended, while respecting anatomical boundaries. A 5- to 10-mm PTV margin is suggested. When using a simultaneous integrated boost technique, a dose of 54 Gy in 30 fractions to gross disease and 45 Gy to elective nodes with chemotherapy is appropriate. Guidelines are provided for OAR delineation. Conclusion: These consensus planning guidelines and high-resolution atlas complement the existing Radiation Therapy Oncology Group (RTOG) elective nodal ano-rectal atlas and provide additional anatomic, clinical, and technical instructions to guide radiation oncologists in the planning and delivery of IMRT for anal cancer.

  1. 78 FR 29096 - Approval and Promulgation of Implementation Plans; Tennessee; Transportation Conformity Revisions

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-05-17

    ... Conformity Revisions AGENCY: Environmental Protection Agency. ACTION: Proposed rule. SUMMARY: EPA is... Division, U.S. Environmental Protection Agency, Region 4, 61 Forsyth Street SW., Atlanta, Georgia 30303... Planning Branch, Air, Pesticides and Toxics Management Division, U.S. Environmental Protection...

  2. 40 CFR 93.109 - Criteria and procedures for determining conformity of transportation plans, programs, and...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... review (transportation plans, TIPs, and FHWA/FTA projects), the relevant pollutant(s), and the status of... for each pollutant and NAAQS. Paragraph (l) of this section addresses conformity requirements for... regional emissions analysis for § 93.118 and/or § 93.119 for a given pollutant and NAAQS, if the area...

  3. 40 CFR 93.109 - Criteria and procedures for determining conformity of transportation plans, programs, and...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... review (transportation plans, TIPs, and FHWA/FTA projects), the relevant pollutant(s), and the status of... for each pollutant and NAAQS. Paragraph (l) of this section addresses conformity requirements for... regional emissions analysis for § 93.118 and/or § 93.119 for a given pollutant and NAAQS, if the area...

  4. 40 CFR 93.107 - Relationship of transportation plan and TIP conformity with the NEPA process.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... degree of specificity required in the transportation plan and the specific travel network assumed for air quality modeling do not preclude the consideration of alternatives in the NEPA process or other project... ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) DETERMINING CONFORMITY OF FEDERAL...

  5. 40 CFR 93.107 - Relationship of transportation plan and TIP conformity with the NEPA process.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... specificity required in the transportation plan and the specific travel network assumed for air quality modeling do not preclude the consideration of alternatives in the NEPA process or other project development... PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) DETERMINING CONFORMITY OF FEDERAL ACTIONS TO STATE...

  6. 40 CFR 93.107 - Relationship of transportation plan and TIP conformity with the NEPA process.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... degree of specificity required in the transportation plan and the specific travel network assumed for air quality modeling do not preclude the consideration of alternatives in the NEPA process or other project... ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) DETERMINING CONFORMITY OF FEDERAL...

  7. 40 CFR 93.107 - Relationship of transportation plan and TIP conformity with the NEPA process.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... degree of specificity required in the transportation plan and the specific travel network assumed for air quality modeling do not preclude the consideration of alternatives in the NEPA process or other project... ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) DETERMINING CONFORMITY OF FEDERAL...

  8. A DVH-guided IMRT optimization algorithm for automatic treatment planning and adaptive radiotherapy replanning

    SciTech Connect

    Zarepisheh, Masoud; Li, Nan; Long, Troy; Romeijn, H. Edwin; Tian, Zhen; Jia, Xun; Jiang, Steve B.

    2014-06-15

    Purpose: To develop a novel algorithm that incorporates prior treatment knowledge into intensity modulated radiation therapy optimization to facilitate automatic treatment planning and adaptive radiotherapy (ART) replanning. Methods: The algorithm automatically creates a treatment plan guided by the DVH curves of a reference plan that contains information on the clinician-approved dose-volume trade-offs among different targets/organs and among different portions of a DVH curve for an organ. In ART, the reference plan is the initial plan for the same patient, while for automatic treatment planning the reference plan is selected from a library of clinically approved and delivered plans of previously treated patients with similar medical conditions and geometry. The proposed algorithm employs a voxel-based optimization model and navigates the large voxel-based Pareto surface. The voxel weights are iteratively adjusted to approach a plan that is similar to the reference plan in terms of the DVHs. If the reference plan is feasible but not Pareto optimal, the algorithm generates a Pareto optimal plan with the DVHs better than the reference ones. If the reference plan is too restricting for the new geometry, the algorithm generates a Pareto plan with DVHs close to the reference ones. In both cases, the new plans have similar DVH trade-offs as the reference plans. Results: The algorithm was tested using three patient cases and found to be able to automatically adjust the voxel-weighting factors in order to generate a Pareto plan with similar DVH trade-offs as the reference plan. The algorithm has also been implemented on a GPU for high efficiency. Conclusions: A novel prior-knowledge-based optimization algorithm has been developed that automatically adjust the voxel weights and generate a clinical optimal plan at high efficiency. It is found that the new algorithm can significantly improve the plan quality and planning efficiency in ART replanning and automatic treatment

  9. Pictorial review. Magnetic resonance for radiotherapy management and treatment planning in prostatic carcinoma.

    PubMed

    Lim, Christopher; Malone, Shawn C; Avruch, Leonard; Breau, Rodney H; Flood, Trevor A; Lim, Megan; Morash, Christopher; Quon, Jeff S; Walsh, Cynthia; Schieda, Nicola

    2015-10-01

    MRI has an important role for radiotherapy (RT) treatment planning in prostate cancer (PCa) providing accurate visualization of the dominant intraprostatic lesion (DIL) and locoregional anatomy, assessment of local staging and depiction of implanted devices. MRI enables the radiation oncologist to optimize RT planning by better defining target tumour volumes (thereby increasing local tumour control), as well as decreasing morbidity (by minimizing the dose to adjacent normal structures). Using MRI, radiation oncologists can define the DIL for delivery of boost doses of RT using a variety of techniques including: stereotactic body radiotherapy, intensity-modulated radiotherapy, proton RT or brachytherapy to improve tumour control. Radiologists require a familiarity with the different RT methods used to treat PCa, as well as an understanding of the advantages and disadvantages of the various MR pulse sequences available for RT planning in order to provide an optimal multidisciplinary RT treatment approach to PCa. Understanding the expected post-RT appearance of the prostate and typical characteristics of local tumour recurrence is also important because MRI is rapidly becoming an integral component for diagnosis, image-guided histological sampling and treatment planning in the setting of biochemical failure after RT or surgery. PMID:26279086

  10. Delivery validation of an automated modulated electron radiotherapy plan

    SciTech Connect

    Connell, T. Papaconstadopoulos, P.; Alexander, A.; Serban, M.; Devic, S.; Seuntjens, J.

    2014-06-15

    Purpose: Modulated electron radiation therapy (MERT) represents an active area of interest that offers the potential to improve healthy tissue sparing in treatment of certain cancer cases. Challenges remain however in accurate beamlet dose calculation, plan optimization, collimation method, and delivery accuracy. In this work, the authors investigate the accuracy and efficiency of an end-to-end MERT plan and automated delivery method. Methods: Treatment planning was initiated on a previously treated whole breast irradiation case including an electron boost. All dose calculations were performed using Monte Carlo methods and beam weights were determined using a research-based treatment planning system capable of inverse optimization. The plan was delivered to radiochromic film placed in a water equivalent phantom for verification, using an automated motorized tertiary collimator. Results: The automated delivery, which covered four electron energies, 196 subfields, and 6183 total MU was completed in 25.8 min, including 6.2 min of beam-on time. The remainder of the delivery time was spent on collimator leaf motion and the automated interfacing with the accelerator in service mode. Comparison of the planned and delivered film dose gave 3%/3mm gamma pass rates of 62.1%, 99.8%, 97.8%, 98.3%, and 98.7% for the 9, 12, 16, and 20 MeV, and combined energy deliveries, respectively. Delivery was also performed with a MapCHECK device and resulted in 3%/3  mm gamma pass rates of 88.8%, 86.1%, 89.4%, and 94.8% for the 9, 12, 16, and 20 MeV energies, respectively. Conclusions: Results of the authors’ study showed that an accurate delivery utilizing an add-on tertiary electron collimator is possible using Monte Carlo calculated plans and inverse optimization, which brings MERT closer to becoming a viable option for physicians in treating superficial malignancies.

  11. Volumetric modulated arc planning for lung stereotactic body radiotherapy using conventional and unflattened photon beams: a dosimetric comparison with 3D technique

    PubMed Central

    2011-01-01

    Purpose Frequently, three-dimensional (3D) conformal beams are used in lung cancer stereotactic body radiotherapy (SBRT). Recently, volumetric modulated arc therapy (VMAT) was introduced as a new treatment modality. VMAT techniques shorten delivery time, reducing the possibility of intrafraction target motion. However dose distributions can be quite different from standard 3D therapy. This study quantifies those differences, with focus on VMAT plans using unflattened photon beams. Methods A total of 15 lung cancer patients previously treated with 3D or VMAT SBRT were randomly selected. For each patient, non-coplanar 3D, coplanar and non-coplanar VMAT and flattening filter free VMAT (FFF-VMAT) plans were generated to meet the same objectives with 50 Gy covering 95% of the PTV. Two dynamic arcs were used in each VMAT plan. The couch was set at ± 5° to the 0° straight position for the two non-coplanar arcs. Pinnacle version 9.0 (Philips Radiation Oncology, Fitchburg WI) treatment planning system with VMAT capabilities was used. We analyzed the conformity index (CI), which is the ratio of the total volume receiving at least the prescription dose to the target volume receiving at least the prescription dose; the conformity number (CN) which is the ratio of the target coverage to CI; and the gradient index (GI) which is the ratio of the volume of 50% of the prescription isodose to the volume of the prescription isodose; as well as the V20, V5, and mean lung dose (MLD). Paired non-parametric analysis of variance tests with post-tests were performed to examine the statistical significance of the differences of the dosimetric indices. Results Dosimetric indices CI, CN and MLD all show statistically significant improvement for all studied VMAT techniques compared with 3D plans (p < 0.05). V5 and V20 show statistically significant improvement for the FFF-VMAT plans compared with 3D (p < 0.001). GI is improved for the FFF-VMAT and the non-coplanar VMAT plans (p < 0.01 and p

  12. Survival and Quality of Life After Stereotactic or 3D-Conformal Radiotherapy for Inoperable Early-Stage Lung Cancer

    SciTech Connect

    Widder, Joachim; Postmus, Douwe; Ubbels, Jan F.; Wiegman, Erwin M.; Langendijk, Johannes A.

    2011-11-15

    Purpose: To investigate survival and local recurrence after stereotactic ablative radiotherapy (SABR) or three-dimensional conformal radiotherapy (3D-CRT) administered for early-stage primary lung cancer and to investigate longitudinal changes of health-related quality of life (HRQOL) parameters after either treatment. Methods and Materials: Two prospective cohorts of inoperable patients with T1-2N0M0 primary lung tumors were analyzed. Patients received 70 Gy in 35 fractions with 3D-CRT or 60 Gy in three to eight fractions with SABR. Global quality of life (GQOL), physical functioning (PF), and patient-rated dyspnea were assessed using the respective dimensions of European Organization for Research and Treatment of Cancer Core Questionnaire-C30 and LC13. HRQOL was analyzed using multivariate linear mixed-effects modeling, survival and local control (LC) using the Kaplan-Meier method, Cox proportional hazards analysis, and Fine and Gray multivariate competing risk analysis as appropriate. Results: Overall survival (OS) was better after SABR compared with 3D-CRT with a HR of 2.6 (95% confidence interval [CI]: 1.5-4.8; p < 0.01). 3D-CRT conferred a subhazard ratio for LC of 5.0 (95% CI: 1.7-14.7; p < 0.01) compared with SABR. GQOL and PF were stable after SABR (p = 0.21 and p = 0.62, respectively). Dyspnea increased after SABR by 3.2 out of 100 points (95% CI: 1.0-5.3; p < 0.01), which is clinically insignificant. At 1 year, PF decreased by an excess of 8.7 out of 100 points (95% CI: 2.8-14.7; p < 0.01) after 3D-CRT compared with SABR. Conclusion: In this nonrandomized comparison of two prospective cohorts of medically inoperable patients with Stage I lung cancer, OS and LC were better after SABR. GQOL, PF, and patient-rated dyspnea were stable after SABR, whereas PF decreased after 3D-CRT approaching clinical significance already at 1 year.

  13. SU-E-T-139: Dynamic Conformal Arcs Vs. VMAT for Stereotactic Lung Target Treatment Planning

    SciTech Connect

    Hershberger, J; Morales, M; Ding, G

    2014-06-01

    Purpose: To investigate if Dynamic Conformal Arcs (DCA) can be used to achieve similar target coverage and conformality as that of using VMAT for Stereotactic Body Radiation Therapy (SBRT) for Lung cases. Methods: We retrospectively re-planned 11 patients that were treated with SBRT for lung tumors using only a single conformal arc, broken into three or four arc segments and weighted differentially in order to achieve the dosimetric constraints as outlined in RTOG 0915 protocol. These re-plans of using DCA were compared with those of using VMAT in terms of the Planning Tumor Volume (PTV) coverage goals, Maximum Dose 2 cm away (D {sub 2}cm), High Dose Spillage, Intermediate Dose Spillage, Lung volume getting 5 Gy (V{sub 5}), and number of monitor units (MU). Results: Of the 11 cases, only three DCA plans failed the D{sub 2}cm parameter, and one VMAT plan failed. None of the 11 patients failed the High Dose Spillage in either technique. For Intermediate Dose Spillage, one DCA plan failed and none failed for VMAT plans. The average V{sub 5} for DCA was 10.5 percent, with VMAT reporting 11.7 percent. The average number of MU for DCA and VMAT were 2605 and 3451, respectively. Conclusion: DCA is able to achieve very similar treatment planning goals as that of using VMAT in treating SBRT Lung tumors in most cases with simplicity. In addition, the DCA technique produces an acceptable plan with lower V{sub 5} in less MU when dose to OAR concerns are at minimum. However, DCA has shown its limitations when the target is close to multiple OAR.

  14. SU-D-19A-06: The Effect of Beam Parameters On Very High-Energy Electron Radiotherapy: A Planning Study

    SciTech Connect

    Palma, B; Bazalova, M; Qu, B; Loo, B; Maxim, P; Hardemark, B; Hynning, E

    2014-06-01

    Purpose: We evaluated the effect of very high-energy electron (VHEE) beam parameters on the planning of a lung cancer case by means of Monte Carlo simulations. Methods: We simulated VHEE radiotherapy plans using the EGSnrc/BEAMnrc-DOSXYZnrc code. We selected a lung cancer case that was treated with 6MV photon VMAT to be planned with VHEE. We studied the effect of beam energy (80 MeV, 100 MeV, and 120 MeV), number of equidistant beams (16 or 32), and beamlets sizes (3 mm, 5 mm or 7 mm) on PTV coverage, sparing of organs at risk (OARs) and dose conformity. Inverse-planning optimization was performed in a research version of RayStation (RaySearch Laboratories AB) using identical objective functions and constraints for all VHEE plans. Results: Similar PTV coverage and dose conformity was achieved by all the VHEE plans. The 100 MeV and 120 MeV VHEE plans were equivalent amongst them and were superior to the 80 MeV plan in terms of OARs sparing. The effect of using 16 or 32 equidistant beams was a mean difference in average dose of 2.4% (0%–7.7%) between the two plans. The use of 3 mm beamlet size systematically reduced the dose to all the OARs. Based on these results we selected the 100MeV-16beams-3mm-beamlet-size plan to compare it against VMAT. The selected VHEE plan was more conformal than VMAT and improved OAR sparing (heart and trachea received 125% and 177% lower dose, respectively) especially in the low-dose region. Conclusion: We determined the VHEE beam parameters that maximized the OAR dose sparing and dose conformity of the actually delivered VMAT plan of a lung cancer case. The selected parameters could be used for the planning of other treatment sites with similar size, shape, and location. For larger targets, a larger beamlet size might be used without significantly increasing the dose. B Palma: None. M Bazalova: None. B Hardemark: Employee, RaySearch Americas. E Hynning: Employee, RaySearch Americas. B Qu: None. B Loo Jr.: Research support, Ray

  15. Intensity-Modulated and 3D-Conformal Radiotherapy for Whole-Ventricular Irradiation as Compared With Conventional Whole-Brain Irradiation in the Management of Localized Central Nervous System Germ Cell Tumors

    SciTech Connect

    Chen, Michael Jenwei; Silva Santos, Adriana da; Sakuraba, Roberto Kenji; Lopes, Cleverson Perceu; Goncalves, Vinicius Demanboro; Weltman, Eduardo; Ferrigno, Robson; Cruz, Jose Carlos

    2010-02-01

    Purpose: To compare the sparing potential of cerebral hemispheres with intensity-modulated radiotherapy (IMRT) and three-dimensional conformal radiotherapy (3D-CRT) for whole-ventricular irradiation (WVI) and conventional whole-brain irradiation (WBI) in the management of localized central nervous system germ cell tumors (CNSGCTs). Methods and Materials: Ten cases of patients with localized CNSGCTs and submitted to WVI by use of IMRT with or without a 'boost' to the primary lesion were selected. For comparison purposes, similar treatment plans were produced by use of 3D-CRT (WVI with or without boost) and WBI (opposed lateral fields with or without boost), and cerebral hemisphere sparing was evaluated at dose levels ranging from 2 Gy to 40 Gy. Results: The median prescription dose for WVI was 30.6 Gy (range, 25.2-37.5 Gy), and that for the boost was 16.5 Gy (range, 0-23.4 Gy). Mean irradiated cerebral hemisphere volumes were lower for WVI with IMRT than for 3D-CRT and were lower for WVI with 3D-CRT than for WBI. Intensity-modulated radiotherapy was associated with the lowest irradiated volumes, with reductions of 7.5%, 12.2%, and 9.0% at dose levels of 20, 30, and 40 Gy, respectively, compared with 3D-CRT. Intensity-modulated radiotherapy provided statistically significant reductions of median irradiated volumes at all dose levels (p = 0.002 or less). However, estimated radiation doses to peripheral areas of the body were 1.9 times higher with IMRT than with 3D-CRT. Conclusions: Although IMRT is associated with increased radiation doses to peripheral areas of the body, its use can spare a significant amount of normal central nervous system tissue compared with 3D-CRT or WBI in the setting of CNSGCT treatment.

  16. Single Photon Emission Computed Tomography-Based Three-Dimensional Conformal Radiotherapy for Hepatocellular Carcinoma With Portal Vein Tumor Thrombus

    SciTech Connect

    Shirai, Shintaro; Sato, Morio Suwa, Kazuhiro; Kishi, Kazushi; Shimono, Chigusa; Kawai, Nobuyuki; Tanihata, Hirohiko; Minamiguchi, Hiroki; Nakai, Motoki

    2009-03-01

    Purpose: To evaluate the safety and efficacy of three-dimensional conformal radiotherapy (3D-CRT) using single photon emission computed tomography (SPECT) in unresectable hepatocellular carcinoma (HCC) with portal vein tumor thrombus (PVTT). Methods and Materials: Patients with HCC with PVTT in the first branch and/or main trunk were selected for this study. The optimal beam directions for 3D-CRT were explored using a Tc-99m-galactosyl human serum albumin SPECT image for guidance. The SPECT image was classified as either wedge type or localized type. The clinical target volume to a total dose of 45 or 50 Gy per 18-20 fractions included the main tumor and PVTT in the wedge type and PVTT alone in the localized type. Results: Twenty-six patients were enrolled: 18 with wedge type and 8 with localized type. Mean tumor size was 7.1 cm (range, 4.4-12.3 cm). Clinical target volumes of wedge type vs. localized type were 111.2 cm{sup 3} vs. 48.4 cm{sup 3} (p = 0.010), respectively. Mean dose to normal liver and mean dose to functional liver were 1185 cGy and 988 cGy (p = 0.001) in wedge type and 1046 cGy and 1043 cGy (p = 0.658) in localized type, respectively. Despite an incidence of Child-Pugh B and C of 57.7%, no patients experienced radiation-induced liver disease. The progression of PVTT was inhibited, with an incidence of 92.2%; survival rates at 1 and 2 years were 44% and 30%, respectively. Conclusion: Single photon emission computed tomography-based 3D-CRT enables irradiation of both the main tumor and PVTT with low toxicity and promising survival.

  17. Combination of Transarterial Chemoembolization and Three-Dimensional Conformal Radiotherapy for Hepatocellular Carcinoma With Inferior Vena Cava Tumor Thrombus

    SciTech Connect

    Koo, Ja Eun; Kim, Jong Hoon; Lim, Young-Suk

    2010-09-01

    Purpose: To evaluate the effects of transarterial chemoembolization (TACE) and three-dimensional conformal radiotherapy (CRT) in patients with hepatocellular carcinoma (HCC) and inferior vena cava tumor thrombus (IVCTT). Methods and Materials: A total of 42 consecutive patients who underwent TACE and CRT (TACE+CRT group) for the treatment of HCC with IVCTT were prospectively enrolled from July 2004 to October 2006. As historical controls, 29 HCC patients with IVCTT who received TACE alone (TACE group) between July 2003 and June 2004 were included. CRT was designed to target only the IVCTT and to deliver a median total dose of 45 Gy (range, 28-50 Gy). Results: Most baseline characteristics of the two groups were similar (p > 0.05). The response and progression-free rates of IVCTT were significantly higher in the TACE+CRT group than in the TACE group (42.9% and 71.4% vs. 13.8% and 37.9%, respectively; p < 0.01 for both rates). Overall, patient survival was significantly higher in the TACE+CRT group than in the TACE group (p < 0.01), with a median survival time of 11.7 months and 4.7 months, respectively. Treatment with TACE+CRT (hazard ratio [HR] = 0.38; 95% confidence interval [CI], 0.20-0.71), progression of IVCTT (HR = 4.05; 95% CI, 2.00-8.21), Child-Pugh class B (HR = 3.44; 95% CI, 1.79-6.61), and portal vein invasion (HR = 2.31; 95% CI, 1.19-4.50) were identified as independent predictors of mortality by multivariable analysis. Conclusions: The combination of TACE and CRT is more effective in the control of IVCTT associated with HCC and improves patient survival compared with TACE alone.

  18. Hepatitis B Virus Reactivation After Three-Dimensional Conformal Radiotherapy in Patients With Hepatitis B Virus-Related Hepatocellular Carcinoma

    SciTech Connect

    Kim, Ji Hoon; Park, Joong-Won Kim, Tae Hyun; Koh, Dong Wook; Lee, Woo Jin; Kim, Chang-Min

    2007-11-01

    Purpose: To investigate whether three-dimensional conformal radiotherapy (3D-CRT) influences hepatitis B virus (HBV) reactivation and chronic hepatitis B (CHB) exacerbation in patients with HBV-related hepatocellular carcinoma (HCC). Methods and Materials: Of the 48 HCC patients with HBV who underwent 3D-CRT to the liver, 16 underwent lamivudine therapy before and during 3D-CRT (Group 1) and 32 did not receive antiviral therapy before 3D-CRT (Group 2). To analyze spontaneous HBV reactivation, we included a control group of 43 HCC patients who did not receive any specific treatment for HCC or CHB. Results: The cumulative rate of radiation-induced liver disease for Groups 1 and 2 was 12.5% (2 of 16) and 21.8% (7 of 32), respectively (p > 0.05). The cumulative rate of HBV reactivation was significantly greater in Group 2 (21.8%, 7 of 32) than in Group 1 (0%, 0/16) or the control group (2.3%, 1 of 43; p < 0.05 each). The cumulative rate of CHB exacerbation, however, did not differ significantly between Groups 2 (12.5%, 4 of 32) and 1 (0%, 0 of 16) or the control group (2.3%, 1 of 43; p > 0.05 each). The CHB exacerbations in the 4 Group 2 patients had radiation-induced liver disease features but were differentiated by serum HBV DNA changes. Two of these patients required antiviral therapy and effectively recovered with lamivudine therapy. Conclusions: In patients with HBV-related HCC undergoing 3D-CRT, HBV reactivation and consequent CHB exacerbation should be considered in the differential diagnosis of radiation-induced liver disease, and antiviral therapy might be considered for the prevention of liver function deterioration after RT.

  19. Automated Planning of Tangential Breast Intensity-Modulated Radiotherapy Using Heuristic Optimization

    SciTech Connect

    Purdie, Thomas G.; Dinniwell, Robert E.; Letourneau, Daniel; Hill, Christine; Sharpe, Michael B.

    2011-10-01

    Purpose: To present an automated technique for two-field tangential breast intensity-modulated radiotherapy (IMRT) treatment planning. Method and Materials: A total of 158 planned patients with Stage 0, I, and II breast cancer treated using whole-breast IMRT were retrospectively replanned using automated treatment planning tools. The tools developed are integrated into the existing clinical treatment planning system (Pinnacle{sup 3}) and are designed to perform the manual volume delineation, beam placement, and IMRT treatment planning steps carried out by the treatment planning radiation therapist. The automated algorithm, using only the radio-opaque markers placed at CT simulation as inputs, optimizes the tangential beam parameters to geometrically minimize the amount of lung and heart treated while covering the whole-breast volume. The IMRT parameters are optimized according to the automatically delineated whole-breast volume. Results: The mean time to generate a complete treatment plan was 6 min, 50 s {+-} 1 min 12 s. For the automated plans, 157 of 158 plans (99%) were deemed clinically acceptable, and 138 of 158 plans (87%) were deemed clinically improved or equal to the corresponding clinical plan when reviewed in a randomized, double-blinded study by one experienced breast radiation oncologist. In addition, overall the automated plans were dosimetrically equivalent to the clinical plans when scored for target coverage and lung and heart doses. Conclusion: We have developed robust and efficient automated tools for fully inversed planned tangential breast IMRT planning that can be readily integrated into clinical practice. The tools produce clinically acceptable plans using only the common anatomic landmarks from the CT simulation process as an input. We anticipate the tools will improve patient access to high-quality IMRT treatment by simplifying the planning process and will reduce the effort and cost of incorporating more advanced planning into clinical

  20. Clinical outcome of hypofractionated conventional conformation radiotherapy for patients with single and no more than three metastatic brain tumors, with noninvasive fixation of the skull without whole brain irradiation

    SciTech Connect

    Aoki, Masahiko . E-mail: maoki-rad@umin.ac.jp; Abe, Yoshinao; Hatayama, Yoshiomi; Kondo, Hidehiro; Basaki, Kiyoshi

    2006-02-01

    Purpose: To evaluate the efficacy and toxicity of hypofractionated conventional conformation radiotherapy (HCCRT) with noninvasive fixation of the skull on patients with single or several brain metastases. Methods and Materials: The subjects were 44 patients who had three or fewer brain metastases (26 solitary, 18 multiple). Treatment was conducted on 65 metastases by rotational conformal beam or multiple fixed coplanar beams with a standard linear accelerator. The planning target volume consisted of the tumor and a 1-cm safety margin. The median isocentric dose was 24 Gy (range, 18-30 Gy) in 3-5 fractions. Whole-brain irradiation was not applied as an initial treatment. Results: Actuarial local tumor control rates at 6 months and 1 year were 78.4% and 71.9%, respectively. In-field recurrence was noted in 10 of 65 tumors, and repeat HCCRT was applied in 5 tumors. Actuarial overall survival rates at 1 year, 2 years, and the median survival time were 50.8%, 24.1%, and 5.8 months, respectively. The patients with an active primary cancer and poor performance status had a poorer prognosis than those without those factors. Actuarial freedom from second brain metastases rates at 6 months, 1 year, and 2 years were 86.6%, 69.0%, and 40.9%, respectively. Second brain metastases were observed in 9 of 44 patients. Lung adenocarcinomas had a higher risk of second brain metastasis than others. Treatment-related severe early or late complications were not observed in this series. Conclusions: Hypofractionated conventional conformation radiotherapy achieved sufficient tumor control and survival. The results suggest that HCCRT would be one of the alternatives for patients with either solitary or several brain metastases.

  1. Monte Carlo calculation of dose distributions in oligometastatic patients planned for spine stereotactic ablative radiotherapy

    NASA Astrophysics Data System (ADS)

    Moiseenko, V.; Liu, M.; Loewen, S.; Kosztyla, R.; Vollans, E.; Lucido, J.; Fong, M.; Vellani, R.; Popescu, I. A.

    2013-10-01

    Dosimetric consequences of plans optimized using the analytical anisotropic algorithm (AAA) implemented in the Varian Eclipse treatment planning system for spine stereotactic body radiotherapy were evaluated by re-calculating with BEAMnrc/DOSXYZnrc Monte Carlo. Six patients with spinal vertebral metastases were planned using volumetric modulated arc therapy. The planning goal was to cover at least 80% of the planning target volume with a prescribed dose of 35 Gy in five fractions. Tissue heterogeneity-corrected AAA dose distributions for the planning target volume and spinal canal planning organ-at-risk volume were compared against those obtained from Monte Carlo. The results showed that the AAA overestimated planning target volume coverage with the prescribed dose by up to 13.5% (mean 8.3% +/- 3.2%) when compared to Monte Carlo simulations. Maximum dose to spinal canal planning organ-at-risk volume calculated with Monte Carlo was consistently smaller than calculated with the treatment planning system and remained under spinal cord dose tolerance. Differences in dose distribution appear to be related to the dosimetric effects of accounting for body composition in Monte Carlo simulations. In contrast, the treatment planning system assumes that all tissues are water-equivalent in their composition and only differ in their electron density.

  2. Influence of 11C-choline PET/CT on radiotherapy planning in prostate cancer

    PubMed Central

    López, Escarlata; Lazo, Antonio; Gutiérrez, Antonio; Arregui, Gregorio; Núñez, Isabel; Sacchetti, Antonio

    2014-01-01

    Aim To evaluate the influence of 11C-choline PET/CT on radiotherapy planning in prostate cancer patients. Background Precise information on the extension of prostate cancer is crucial for the choice of an appropriate therapeutic strategy. 11C-choline positron emission tomography (11C-choline PET/CT) has two roles in radiation oncology (RT): (1) patient selection for treatment and (2) target volume selection and delineation. In conjunction with high-accuracy techniques, it might offer an opportunity of dose escalation and better tumour control while sparing healthy tissues. Materials and methods We carried out a retrospective study in order to analyse RT planning modification based on 11C-choline PET/CT in 16 prostate cancer patients. Patients were treated with hypofractionated step-and-shoot Intensity Modulated Radiotherapy (IMRT), or Volumetric Modulated Arc Therapy (VMAT), and a daily cone-beam CT for Image Guided Radiation Therapy (IGRT). All patients underwent a 11C-choline-PET/CT scan prior to radiotherapy. Results In 37.5% of cases, a re-delineation and new dose prescription occurred. Data show good preliminary clinical results in terms of biochemical control and toxicity. No gastrointestinal (GI)/genitourinary (GU) grade III toxicities were observed after a median follow-up of 9.5 months. Conclusions In our experience, concerning the treatment of prostate cancer (PCa), 11C-choline PET/CT may be helpful in radiotherapy planning, either for dose escalation or exclusion of selected sites. PMID:25859399

  3. PET/CT for Radiotherapy Treatment Planning in Patients With Soft Tissue Sarcomas

    SciTech Connect

    Karam, Irene; Devic, Slobodan; Hickeson, Marc; Roberge, David; Turcotte, Robert E.; Freeman, Carolyn R.

    2009-11-01

    Purpose: To study the possibility of incorporating positron emission tomography/computed tomography (PET/CT) information into radiotherapy treatment planning in patients with high-grade soft tissue sarcomas (STS). Methods and Materials: We studied 17 patients treated with preoperative radiotherapy at our institution from 2005 to 2007. All patients had a high-grade STS and had had a staging PET/CT scan. For each patient, an MRI-based gross tumor volume (GTV), considered to be the contemporary standard for radiotherapy treatment planning, was outlined on a T1-gadolinium enhanced axial MRI (GTV{sub MRI}), and a second set of GTVs were outlined using different threshold values on PET images (GTV{sub PET}). PET-based target volumes were compared with the MRI-based GTV. Threshold values for target contouring were determined as a multiple (from 2 to 10 times) of the background soft tissue uptake values (B) sampled over healthy tissue. Results: PET-based GTVs contoured using a threshold value of 2 or 2.5 most closely resembled the GTV{sub MRI} volumes. Higher threshold values lead to PET volumes much smaller than the GTV{sub MRI}. The standard deviations between the average volumes of GTV{sub PET} and GTV{sub MRI} ratios for all thresholds were large, ranging from 36% for 2 xB up to 93% for 10 xB. Maximum uptake-to-background ratio correlated poorly with the maximum standardized uptake values. Conclusions: It is unlikely that PET/CT will make a significant contribution in GTV definition for radiotherapy treatment planning in patients with STS using threshold methods on PET images. Future studies will focus on molecular imaging and tumor physiology.

  4. Increased risk of biochemical and local failure in patients with distended rectum on the planning CT for prostate cancer radiotherapy

    SciTech Connect

    Crevoisier, Renaud de; Tucker, Susan L. . E-mail: sltucker@mdanderson.org; Dong Lei; Mohan, Radhe; Cheung, Rex; Cox, James D.; Kuban, Deborah A.

    2005-07-15

    Purpose: To retrospectively test the hypothesis that rectal distension on the planning computed tomography (CT) scan is associated with an increased risk of biochemical and local failure among patients irradiated for prostate carcinoma when a daily repositioning technique based on direct prostate-organ localization is not used. Methods and Materials: This study included 127 patients who received definitive three-dimensional conformal radiotherapy for prostate cancer to a total dose of 78 Gy at University of Texas M.D. Anderson Cancer Center. Rectal distension was assessed by calculation of the average cross-sectional rectal area (CSA; defined as the rectal volume divided by length) and measuring three rectal diameters on the planning CT. The impact of rectal distension on biochemical control, 2-year prostate biopsy results, and incidence of Grade 2 or greater late rectal bleeding was assessed. Results: The incidence of biochemical failure was significantly higher among patients with distended rectums (CSA >11.2 cm{sup 2}) on the planning CT scan (p 0.0009, log-rank test). Multivariate analysis indicates that rectal distension and high-risk disease are independent risk factors for biochemical failure, with hazard ratios of 3.89 (95% C.I. 1.58 to 9.56, p = 0.003) and 2.45 (95% C.I. 1.18 to 5.08, p = 0.016), respectively. The probability of residual tumor without evidence of radiation treatment (as scored by the pathologist) increased significantly with rectal distension (p = 0.010, logistic analysis), and a lower incidence of Grade 2 or greater late rectal bleeding within 2 years was simultaneously observed with higher CSA values (p = 0.031, logistic analysis). Conclusions: We found strong evidence that rectal distension on the treatment-planning CT scan decreased the probability of biochemical control, local control, and rectal toxicity in patients who were treated without daily image-guided prostate localization, presumably because of geographic misses. Therefore

  5. Implementation of an Analytical Model for Leakage Neutron Equivalent Dose in a Proton Radiotherapy Planning System

    PubMed Central

    Eley, John; Newhauser, Wayne; Homann, Kenneth; Howell, Rebecca; Schneider, Christopher; Durante, Marco; Bert, Christoph

    2015-01-01

    Equivalent dose from neutrons produced during proton radiotherapy increases the predicted risk of radiogenic late effects. However, out-of-field neutron dose is not taken into account by commercial proton radiotherapy treatment planning systems. The purpose of this study was to demonstrate the feasibility of implementing an analytical model to calculate leakage neutron equivalent dose in a treatment planning system. Passive scattering proton treatment plans were created for a water phantom and for a patient. For both the phantom and patient, the neutron equivalent doses were small but non-negligible and extended far beyond the therapeutic field. The time required for neutron equivalent dose calculation was 1.6 times longer than that required for proton dose calculation, with a total calculation time of less than 1 h on one processor for both treatment plans. Our results demonstrate that it is feasible to predict neutron equivalent dose distributions using an analytical dose algorithm for individual patients with irregular surfaces and internal tissue heterogeneities. Eventually, personalized estimates of neutron equivalent dose to organs far from the treatment field may guide clinicians to create treatment plans that reduce the risk of late effects. PMID:25768061

  6. Implementation of an analytical model for leakage neutron equivalent dose in a proton radiotherapy planning system.

    PubMed

    Eley, John; Newhauser, Wayne; Homann, Kenneth; Howell, Rebecca; Schneider, Christopher; Durante, Marco; Bert, Christoph

    2015-01-01

    Equivalent dose from neutrons produced during proton radiotherapy increases the predicted risk of radiogenic late effects. However, out-of-field neutron dose is not taken into account by commercial proton radiotherapy treatment planning systems. The purpose of this study was to demonstrate the feasibility of implementing an analytical model to calculate leakage neutron equivalent dose in a treatment planning system. Passive scattering proton treatment plans were created for a water phantom and for a patient. For both the phantom and patient, the neutron equivalent doses were small but non-negligible and extended far beyond the therapeutic field. The time required for neutron equivalent dose calculation was 1.6 times longer than that required for proton dose calculation, with a total calculation time of less than 1 h on one processor for both treatment plans. Our results demonstrate that it is feasible to predict neutron equivalent dose distributions using an analytical dose algorithm for individual patients with irregular surfaces and internal tissue heterogeneities. Eventually, personalized estimates of neutron equivalent dose to organs far from the treatment field may guide clinicians to create treatment plans that reduce the risk of late effects. PMID:25768061

  7. Boosting runtime-performance of photon pencil beam algorithms for radiotherapy treatment planning.

    PubMed

    Siggel, M; Ziegenhein, P; Nill, S; Oelfke, U

    2012-10-01

    Pencil beam algorithms are still considered as standard photon dose calculation methods in Radiotherapy treatment planning for many clinical applications. Despite their established role in radiotherapy planning their performance and clinical applicability has to be continuously adapted to evolving complex treatment techniques such as adaptive radiation therapy (ART). We herewith report on a new highly efficient version of a well-established pencil beam convolution algorithm which relies purely on measured input data. A method was developed that improves raytracing efficiency by exploiting the capability of modern CPU architecture for a runtime reduction. Since most of the current desktop computers provide more than one calculation unit we used symmetric multiprocessing extensively to parallelize the workload and thus decreasing the algorithmic runtime. To maximize the advantage of code parallelization, we present two implementation strategies - one for the dose calculation in inverse planning software, and one for traditional forward planning. As a result, we could achieve on a 16-core personal computer with AMD processors a superlinear speedup factor of approx. 18 for calculating the dose distribution of typical forward IMRT treatment plans. PMID:22071169

  8. An integrated Monte Carlo dosimetric verification system for radiotherapy treatment planning

    NASA Astrophysics Data System (ADS)

    Yamamoto, T.; Mizowaki, T.; Miyabe, Y.; Takegawa, H.; Narita, Y.; Yano, S.; Nagata, Y.; Teshima, T.; Hiraoka, M.

    2007-04-01

    An integrated Monte Carlo (MC) dose calculation system, MCRTV (Monte Carlo for radiotherapy treatment plan verification), has been developed for clinical treatment plan verification, especially for routine quality assurance (QA) of intensity-modulated radiotherapy (IMRT) plans. The MCRTV system consists of the EGS4/PRESTA MC codes originally written for particle transport through the accelerator, the multileaf collimator (MLC), and the patient/phantom, which run on a 28-CPU Linux cluster, and the associated software developed for the clinical implementation. MCRTV has an interface with a commercial treatment planning system (TPS) (Eclipse, Varian Medical Systems, Palo Alto, CA, USA) and reads the information needed for MC computation transferred in DICOM-RT format. The key features of MCRTV have been presented in detail in this paper. The phase-space data of our 15 MV photon beam from a Varian Clinac 2300C/D have been developed and several benchmarks have been performed under homogeneous and several inhomogeneous conditions (including water, aluminium, lung and bone media). The MC results agreed with the ionization chamber measurements to within 1% and 2% for homogeneous and inhomogeneous conditions, respectively. The MC calculation for a clinical prostate IMRT treatment plan validated the implementation of the beams and the patient/phantom configuration in MCRTV.

  9. A dose comparison of proton radiotherapy and photon radiotherapy for pediatric brain tumor

    NASA Astrophysics Data System (ADS)

    Kim, S. Y.; Cho, J. H.

    2014-12-01

    The purpose of this study was to investigate the effectiveness of photon radiotherapy and to compare the dose of treatment planning between proton radiotherapy and 3D conformal radiation therapy (3D-CRT) for pediatric brain tumor patients. This study was conducted in five pediatric brain tumor patients who underwent craniospinal irradiation treatment from October 2013 to April 2014 in the hospital. The study compared organs at risk (OARs) by assessing the dose distribution of normal tissue from the proton plan and 3D-CRT. Furthermore, this study assessed the treatment plans by looking at the homogeneity index (HI) and conformity index (CI). As a result, the study revealed OARs due to the small volume proton radiotherapy dose distribution in the normal tissue. Also, by comparing HI and CI between the 3D-CRT and proton radiotherapy plan, the study found that the dose of proton radiotherapy plan was homogenized. When conducting 3D-CRT and proton radiotherapy in a dose-volume histogram comparison, the dose of distribution turned out to be low. Consequently, proton radiotherapy is used for protecting the normal tissue, and is used in tumor tissue as a homogenized dose for effective treatment.

  10. Monte Carlo Treatment Planning for Molecular Targeted Radiotherapy within the MINERVA System

    SciTech Connect

    Lehmann, J; Siantar, C H; Wessol, D E; Wemple, C A; Nigg, D; Cogliati, J; Daly, T; Descalle, M; Flickinger, T; Pletcher, D; DeNardo, G

    2004-09-22

    The aim of this project is to extend accurate and patient-specific treatment planning to new treatment modalities, such as molecular targeted radiation therapy, incorporating previously crafted and proven Monte Carlo and deterministic computation methods. A flexible software environment is being created that allows planning radiation treatment for these new modalities and combining different forms of radiation treatment with consideration of biological effects. The system uses common input interfaces, medical image sets for definition of patient geometry, and dose reporting protocols. Previously, the Idaho National Engineering and Environmental Laboratory (INEEL), Montana State University (MSU), and Lawrence Livermore National Laboratory (LLNL) had accrued experience in the development and application of Monte Carlo-based, three-dimensional, computational dosimetry and treatment planning tools for radiotherapy in several specialized areas. In particular, INEEL and MSU have developed computational dosimetry systems for neutron radiotherapy and neutron capture therapy, while LLNL has developed the PEREGRINE computational system for external beam photon-electron therapy. Building on that experience, the INEEL and MSU are developing the MINERVA (Modality Inclusive Environment for Radiotherapeutic Variable Analysis) software system as a general framework for computational dosimetry and treatment planning for a variety of emerging forms of radiotherapy. In collaboration with this development, LLNL has extended its PEREGRINE code to accommodate internal sources for molecular targeted radiotherapy (MTR), and has interfaced it with the plug-in architecture of MINERVA. Results from the extended PEREGRINE code have been compared to published data from other codes, and found to be in general agreement (EGS4 - 2%, MCNP - 10%)(Descalle et al. 2003). The code is currently being benchmarked against experimental data. The interpatient variability of the drug pharmacokinetics in MTR