Sample records for cvd-diamant zum teilchennachweis

  1. Tribosystems based on multilayered micro/nanocrystalline CVD diamond coatings =

    NASA Astrophysics Data System (ADS)

    Shabani, Mohammadmehdi

    A combinacao das caracteristicas do diamante microcristalino (MCD) e nanocristalino (NCD), tais como elevada adesao do MCD e a baixa rugosidade superficial e baixo coeficiente de atrito do NCD, e ideal para aplicacoes tribologicas exigentes. Deste modo, o presente trabalho centrou-se no desenvolvimento de revestimentos em multicamada MCD/NCD. Filmes com dez camadas foram depositados em amostras de cerâmicos de Si3N4 pela tecnica de deposicao quimica em fase vapor assistida por filamento quente (HFCVD). A microestrutura, qualidade do diamante e adesao foram investigadas usando tecnicas como SEM, AFM, espectroscopia Raman, DRX, indentacao Brale e perfilometria otica 3D. Diversas geometrias para aplicacoes distintas foram revestidas: discos e esferas para testes tribologicos a escala laboratorial, e para testes em servico, aneis de empanques mecânicos e pastilhas de corte para torneamento. Nos ensaios tribologicos esfera-sobre-plano em movimento reciproco, sob 10-90% de humidade relativa (RH), os valores medios dos coeficientes de atrito maximo e em estado estacionario sao de 0,32 e 0,09, respetivamente. Em relacao aos coeficientes de desgaste, observou-se um valor minimo de cerca de 5,2x10-8 mm3N-1m-1 para valores intermedios de 20-25% de RH. A humidade relativa tem um forte efeito sobre o valor da carga critica que triplica a partir de 40 N a 10% RH para 120 N a 90% de RH. No intervalo de temperaturas 50-100 °C, as cargas criticas sao semelhantes as obtidas em condicoes de baixa RH ( 10-25%). A vida util das ferramentas com revestimento de dez camadas alternadas MCD/NCD e 24 mum de espessura total no torneamento de um composito de matriz metalica Al- 15 vol% Al2O3 (Al-MMC) e melhor do que a maioria das ferramentas de diamante CVD encontradas na literatura, e semelhante a maioria das ferramentas de diamante policristalino (PCD). A formacao de cratera ocorre por desgaste sucessivo das varias camadas, atrasando a delaminacao total do revestimento de diamante do

  2. EKOSAT/DIAMANT - The Earth Observation Programme at OHB- System

    NASA Astrophysics Data System (ADS)

    Penne, B.; Tobehn, C.; Kassebom, M.; Luebberstedt

    This paper covers the EKOSAT / DIAMANT programme heading for superspectral geo-information products. The EKOSAT / DIAMANT programme is based on a commercial strategy just before the realization of the first step - the EKOSAT launch in 2004. Further, we give an overview on OHB-System earth observation prime activities especially for infrared and radar. The EKOSAT/ DIAMANT is based on the MSRS sensor featuring 12 user dedicated spectral bands in the VIS/NIR with 5m spatial resolution and 26 km swath at an orbit of 670 km. The operational demonstrator mission EKOSAT is a Korean-Israelean-German-Russian initiative that aims in utilizing the existing proto-flight model of the KOMPSAT-1 spacecraft for the MSRS sensor, which development is finished. The EKOSAT pointing capability will allow a revisit time of 3 days. DIAMANT stands for the future full operational system based on dedicated small satellites. The basic constellation relying on 2-3 satellites with about one day revisit is extendend on market demand. EKOSAT/ DIAMANT is designed to fill the gap between modern high spatial resolution multispectral (MS) systems and hyperspectral systems with moderate spatial resolution. On European level, there is currently no remote sensing system operational with comparable features and capabilities concerning applications especially in the field of environmental issues, vegetation, agriculture and water bodies. The Space Segment has been designed to satisfy the user requirements based on a balance between commercial aspects and scientific approaches. For example eight spectral bands have been identified to cover almost the entire product range for the current market. Additional four bands have been implemented to be prepared for future applications as for example the improved red edge detection, which give better results regarding environmental conditions. The spacecraft design and its subsystems are still reasonable small in order to keep the mass below 200 kg. This is an

  3. Merger of the DIAMANT Light Charge Particle Detector into the AFRODITE Data Acquisition System

    NASA Astrophysics Data System (ADS)

    Murray, S. H. T.; Mullins, S. M.; Bark, R. A.; Gál, J.; Gueorguieva, E.; Hlatshwayo, T.; Juhász, K.; Kalinka, G.; Komati, F. S.; Krasznahorkay, A.; Lawrie, J. J.; Malwela, T.; Molnár, L.; Ntshangase, S.; Nyakó, B. M.; Pilcher, J. V.; Pucknell, V. F.; Sharpey-Schafer, J. F.; Scheurer, J. N.; Shirinda, O.; Timár, J.; Zolnai, L.

    2005-11-01

    The Chessboard section of the DIAMANT CsI detector array has been merged into the AFRODITE γ-ray spectrometer acquisition system. The details of the data acquisition merging is explained together with how consistency is maintained and ensured between the two distinct systems.

  4. Family history of cardiovascular disease (CVD), perceived CVD risk, and health-related behavior: A review of the literature

    PubMed Central

    Imes, Christopher C.; Lewis, Frances Marcus

    2012-01-01

    Background Over 82 million Americans have one or more forms of cardiovascular disease (CVD), accounting for 32.8% of all deaths in the United States. Although the evidence for the familial aggregation of CVD is strong, the relationship between family history (FH) of CVD, perceived risk for CVD and their relationship to health-related behavior is poorly understood. Objective The objective of this article is to review and summarize the published research on the relationship between a FH of CVD, an individual’s perceived risk, and health-related behavior in order to make recommendations for clinical practice and future research. Methods A literature search was conducted using PubMed, CINAHL Plus, and PsycINFO to identify articles that examined the relationship between a FH of CVD, perceived CVD risk, and health-promoting behaviors. A total of 263 unique articles were reviewed. Two hundred thirty-eight were excluded, resulting in a total of 25 articles included in the paper. Results There was a positive relationship between a reported FH of CVD and perceived risk. However, the relationship between a FH of CVD and health-related behavior change and perceived risk and behavior change was inconsistent. Conclusions A person’s awareness of their FH of CVD or their own risk for CVD is not a sufficient predictor of changes in their health-related behavior. Future studies are needed to better explain the processes by which perceived CVD risk or FH of CVD can be used to affect health-related behavior changes. It appears that both FH and perceived personal risk for CVD are necessary but not sufficient conditions to change health-related behavior in high-risk populations. Future studies should also test interventions that help individuals with a FH of CVD attribute increased personal risk to themselves for developing CVD, while providing lifestyle management options to minimize their risk. PMID:23321782

  5. CVD Polymers for Devices and Device Fabrication.

    PubMed

    Wang, Minghui; Wang, Xiaoxue; Moni, Priya; Liu, Andong; Kim, Do Han; Jo, Won Jun; Sojoudi, Hossein; Gleason, Karen K

    2017-03-01

    Chemical vapor deposition (CVD) polymerization directly synthesizes organic thin films on a substrate from vapor phase reactants. Dielectric, semiconducting, electrically conducting, and ionically conducting CVD polymers have all been readily integrated into devices. The absence of solvent in the CVD process enables the growth of high-purity layers and avoids the potential of dewetting phenomena, which lead to pinhole defects. By limiting contaminants and defects, ultrathin (<10 nm) CVD polymeric device layers have been fabricated in multiple laboratories. The CVD method is particularly suitable for synthesizing insoluble conductive polymers, layers with high densities of organic functional groups, and robust crosslinked networks. Additionally, CVD polymers are prized for the ability to conformally cover rough surfaces, like those of paper and textile substrates, as well as the complex geometries of micro- and nanostructured devices. By employing low processing temperatures, CVD polymerization avoids damaging substrates and underlying device layers. This report discusses the mechanisms of the major CVD polymerization techniques and the recent progress of their applications in devices and device fabrication, with emphasis on initiated CVD (iCVD) and oxidative CVD (oCVD) polymerization. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  6. CVD and Oxidative Stress

    PubMed Central

    Cervantes Gracia, Karla; Llanas-Cornejo, Daniel; Husi, Holger

    2017-01-01

    Nowadays, it is known that oxidative stress plays at least two roles within the cell, the generation of cellular damage and the involvement in several signaling pathways in its balanced normal state. So far, a substantial amount of time and effort has been expended in the search for a clear link between cardiovascular disease (CVD) and the effects of oxidative stress. Here, we present an overview of the different sources and types of reactive oxygen species in CVD, highlight the relationship between CVD and oxidative stress and discuss the most prominent molecules that play an important role in CVD pathophysiology. Details are given regarding common pharmacological treatments used for cardiovascular distress and how some of them are acting upon ROS-related pathways and molecules. Novel therapies, recently proposed ROS biomarkers, as well as future challenges in the field are addressed. It is apparent that the search for a better understanding of how ROS are contributing to the pathophysiology of CVD is far from over, and new approaches and more suitable biomarkers are needed for the latter to be accomplished. PMID:28230726

  7. CVD-graphene for low equivalent series resistance in rGO/CVD-graphene/Ni-based supercapacitors.

    PubMed

    Kwon, Young Hwi; Kumar, Sunil; Bae, Joonho; Seo, Yongho

    2018-05-11

    Reduced equivalent series resistance (ESR) is necessary, particularly at a high current density, for high performance supercapacitors, and the interface resistance between the current collector and electrode material is one of the main components of ESR. In this report, we have optimized chemical vapor deposition-grown graphene (CVD-G) on a current collector (Ni-foil) using reduced graphene oxide as an active electrode material to fabricate an electric double layer capacitor with reduced ESR. The CVD-G was grown at different cooling rates-20 °C min -1 , 40 °C min -1 and 100 °C min -1 -to determine the optimum conditions. The lowest ESR, 0.38 Ω, was obtained for a cell with a 100 °C min -1 cooling rate, while the sample without a CVD-G interlayer exhibited 0.80 Ω. The CVD-G interlayer-based supercapacitors exhibited fast CD characteristics with high scan rates up to 10 Vs -1 due to low ESR. The specific capacitances deposited with CVD-G were in the range of 145.6 F g -1 -213.8 F g -1 at a voltage scan rate of 0.05 V s -1 . A quasi-rectangular behavior was observed in the cyclic voltammetry curves, even at very high scan rates of 50 and 100 V s -1 , for the cell with optimized CVD-G at higher cooling rates, i.e. 100 °C min -1 .

  8. CVD-graphene for low equivalent series resistance in rGO/CVD-graphene/Ni-based supercapacitors

    NASA Astrophysics Data System (ADS)

    Kwon, Young Hwi; Kumar, Sunil; Bae, Joonho; Seo, Yongho

    2018-05-01

    Reduced equivalent series resistance (ESR) is necessary, particularly at a high current density, for high performance supercapacitors, and the interface resistance between the current collector and electrode material is one of the main components of ESR. In this report, we have optimized chemical vapor deposition-grown graphene (CVD-G) on a current collector (Ni-foil) using reduced graphene oxide as an active electrode material to fabricate an electric double layer capacitor with reduced ESR. The CVD-G was grown at different cooling rates—20 °C min‑1, 40 °C min‑1 and 100 °C min‑1—to determine the optimum conditions. The lowest ESR, 0.38 Ω, was obtained for a cell with a 100 °C min‑1 cooling rate, while the sample without a CVD-G interlayer exhibited 0.80 Ω. The CVD-G interlayer-based supercapacitors exhibited fast CD characteristics with high scan rates up to 10 Vs‑1 due to low ESR. The specific capacitances deposited with CVD-G were in the range of 145.6 F g‑1–213.8 F g‑1 at a voltage scan rate of 0.05 V s‑1. A quasi-rectangular behavior was observed in the cyclic voltammetry curves, even at very high scan rates of 50 and 100 V s‑1, for the cell with optimized CVD-G at higher cooling rates, i.e. 100 °C min‑1.

  9. All-Cause and CVD Mortality in Native Hawaiians

    PubMed Central

    Aluli, N. Emmett; Reyes, Phillip W.; Brady, S. Kalani; Tsark, JoAnn U.; Jones, Kristina L.; Mau, Marjorie; Howard, Wm. J.; Howard, Barbara V.

    2010-01-01

    Aims Cardiovascular disease (CVD) is the leading cause of death among Native Hawaiians. In this article, all-cause and cardiovascular mortality rates among Native Hawaiians are examined, along with associated CVD risk factors. Methods A total of 855 Native Hawaiians (343 men and 512 women, ages 19–88) were examined as participants of the Cardiovascular Risk Clinics program (1992–1998) and underwent surveillance through September 2007. Cause of each death was determined by review of medical records, death certificates, newspapers, and through queries to community members. Results CVD accounted for 55% of deaths. Coronary heart disease (CHD) accounted for the majority of CVD deaths. CVD increased with age and was higher in those with diabetes, hypertension, or high low-density lipoprotein cholesterol (LDL-C). CVD rates were higher in men than in women and 4-fold higher in those with diabetes. In addition to age, diabetes, hypertension, and elevated LDL-C were major risk factors. Conclusions Diabetes is a major determinant of CVD in this population and most of the CVD is occurring in those with diabetes. Strategies to prevent diabetes and manage blood pressure and lipids should reduce CVD rates in Native Hawaiians. PMID:20392507

  10. Discovery Of An Extensive Hydrothermal Sulfide/Sulfate Mounds Field In East Diamante Caldera, Mariana Volcanic Arc

    NASA Astrophysics Data System (ADS)

    Hein, J. R.; de Ronde, C. E.; Ditchburn, R.; Leybourne, M. I.; Tamura, Y.; Stern, R. J.; Conrad, T. A.; Nichols, A. R.; Shukuno, H.; Embley, R. W.; Bloomer, S. H.; Ishizuka, O.; Hirahara, Y.; Senda, R.; Nunokawa, A.; Jordan, E.; Wada, I.

    2010-12-01

    An elongate field of hydrothermal mounds was discovered along the NE flank of a cluster of resurgent dacite domes in East Diamante Caldera using the ROV Hyper-Dolphin aboard the R.V. Natsushima in June 2009 and July 2010. East Diamante seamount lies about 80 km north of Saipan and is the northernmost volcano of the Southern Seamount Province of the Mariana magmatic arc. East Diamante is an irregular caldera about 10 km x 4 km that is breached on the north and south sides. The caldera floor has a maximum water depth of about 700 m. After caldera collapse, dacitic domes intruded into the center of the caldera providing the heat source for production and circulation of hydrothermal fluids that generated the large mounds field and two nearby chimney fields, one active and one inactive, found in 2004 during a NOAA Ring-of-Fire cruise. The mounds field is more than 100 m long and about 25-30 m wide and occurs along a NE-SW rift valley at water depths of about 365-400 m b.s.l. Individual hydrothermal mounds and ridges along this trend vary in size and the bases of the mounds are buried beneath hydrothermal sediment so that only minimum dimensions can be determined. Mounds are typically 1-3 m tall and 0.5-2 m wide, with lengths of about 3 to more than 5 m. The sulfide/sulfate mounds are layered and an iron- and manganese-oxide subsidiary mound venting low-temperature fluids caps some of them. Some mounds also support inactive sulfide/sulfate chimneys and spires; chimneys rarely occur as independent structures within the mounds field. The mounds are composed primarily of barite layers and sphalerite (high cadmium, low iron) plus galena layers with up to 470 ppm silver and 3 ppm gold. The subsidiary mounds are composed of 7A manganate and goethite that occur around a delicate network of 2-10 mm diameter anastomosing channels. Similar oxides cover the seabed throughout the mounds field and precipitated from diffuse fluid flow throughout the region, but formed by both diffuse

  11. Fermented dairy food and CVD risk.

    PubMed

    Tapsell, Linda C

    2015-04-01

    Fermented dairy foods such as yoghurt and cheese are commonly found in the Mediterranean diet. Recent landmark research has confirmed the effect of the Mediterranean diet on reducing the CVD risk, but the relative contributions of fermented dairy foods have not been fully articulated. The present study provides a review of the relationship between fermented dairy foods consumption and CVD risk in the context of the whole diet. Studies show that people who eat healthier diets may be more likely to consume yoghurt, so there is a challenge in attributing separate effects to yoghurt. Analyses from large population studies list yoghurt as the food most negatively associated with the risk of weight gain (a problem that may lead to CVD). There is some suggestion that fermented dairy foods consumption (yoghurt or cheese) may be associated with reduced inflammatory biomarkers associated with the development of CVD. Dietary trials suggest that cheese may not have the same effect on raising LDL-cholesterol levels as butter with the same saturated fat content. The same might be stated for yoghurt. The use of different probiotic cultures and other aspects of study design remain a problem for research. Nevertheless, population studies from a range of countries have shown that a reduced risk of CVD occurs with the consumption of fermented dairy foods. A combination of evidence is necessary, and more research is always valuable, but indications remain that fermented dairy foods such as cheese and yoghurt are integral to diets that are protective against CVD.

  12. Fracture Characteristics of Monolayer CVD-Graphene

    PubMed Central

    Hwangbo, Yun; Lee, Choong-Kwang; Kim, Sang-Min; Kim, Jae-Hyun; Kim, Kwang-Seop; Jang, Bongkyun; Lee, Hak-Joo; Lee, Seoung-Ki; Kim, Seong-Su; Ahn, Jong-Hyun; Lee, Seung-Mo

    2014-01-01

    We have observed and analyzed the fracture characteristics of the monolayer CVD-graphene using pressure bulge testing setup. The monolayer CVD-graphene has appeared to undergo environmentally assisted subcritical crack growth in room condition, i.e. stress corrosion cracking arising from the adsorption of water vapor on the graphene and the subsequent chemical reactions. The crack propagation in graphene has appeared to be able to be reasonably tamed by adjusting applied humidity and stress. The fracture toughness, describing the ability of a material containing inherent flaws to resist catastrophic failure, of the CVD-graphene has turned out to be exceptionally high, as compared to other carbon based 3D materials. These results imply that the CVD-graphene could be an ideal candidate as a structural material notwithstanding environmental susceptibility. In addition, the measurements reported here suggest that specific non-continuum fracture behaviors occurring in 2D monoatomic structures can be macroscopically well visualized and characterized. PMID:24657996

  13. ZumBeat: Evaluation of a Zumba Dance Intervention in Postmenopausal Overweight Women

    PubMed Central

    Rossmeissl, Anja; Lenk, Soraya; Hanssen, Henner; Donath, Lars; Schmidt-Trucksäss, Arno; Schäfer, Juliane

    2016-01-01

    Physical inactivity is a major public health concern since it increases individuals’ risk of morbidity and mortality. A subgroup at particular risk is postmenopausal overweight women. The aim of this study was to assess the feasibility and effect of a 12-week ZumBeat dance intervention on cardiorespiratory fitness and psychosocial health. Postmenopausal women with a body mass index (BMI) >30 kg/m2 or a waist circumference >94 cm who were not regularly physically active were asked to complete a 12-week ZumBeat dance intervention with instructed and home-based self-training sessions. Before and after the intervention, peak oxygen consumption (VO2peak) was assessed on a treadmill; and body composition and several psychometric parameters (including quality of life, sports-related barriers and menopausal symptoms) were investigated. Of 17 women (median age: 54 years; median BMI: 30 kg/m2) enrolled in the study, 14 completed the study. There was no apparent change in VO2peak after the 12-week intervention period (average change score: −0.5 mL/kg/min; 95% confidence interval: −1.0, 0.1); but, quality of life had increased, and sports-related barriers and menopausal symptoms had decreased. A 12-week ZumBeat dance intervention may not suffice to increase cardiorespiratory fitness in postmenopausal overweight women, but it increases women’s quality of life. PMID:29910253

  14. New developments in CVD diamond for detector applications

    NASA Astrophysics Data System (ADS)

    Adam, W.; Berdermann, E.; Bergonzo, P.; de Boer, W.; Bogani, F.; Borchi, E.; Brambilla, A.; Bruzzi, M.; Colledani, C.; Conway, J.; D'Angelo, P.; Dabrowski, W.; Delpierre, P.; Dulinski, W.; Doroshenko, J.; van Eijk, B.; Fallou, A.; Fischer, P.; Fizzotti, F.; Furetta, C.; Gan, K. K.; Ghodbane, N.; Grigoriev, E.; Hallewell, G.; Han, S.; Hartjes, F.; Hrubec, J.; Husson, D.; Kagan, H.; Kaplon, J.; Kass, R.; Keil, M.; Knoepfle, K. T.; Koeth, T.; Krammer, M.; Logiudice, A.; Lu, R.; Mac Lynne, L.; Manfredotti, C.; Meier, D.; Menichelli, D.; Meuser, S.; Mishina, M.; Moroni, L.; Noomen, J.; Oh, A.; Pernicka, M.; Perera, L.; Potenza, R.; Riester, J. L.; Roe, S.; Rudge, A.; Sala, S.; Sampietro, M.; Schnetzer, S.; Sciortino, S.; Stelzer, H.; Stone, R.; Sutera, C.; Trischuk, W.; Tromson, D.; Tuve, C.; Vincenzo, B.; Weilhammer, P.; Wermes, N.; Wetstein, M.; Zeuner, W.; Zoeller, M.

    Chemical Vapor Deposition (CVD) diamond has been discussed extensively as an alternative sensor material for use very close to the interaction region of the LHC and other machines where extreme radiation conditions exist. During the last seven years the RD42 collaboration has developed diamond detectors and tested them with LHC electronics towards the end of creating a device usable by experiments. The most recent results of this work are presented. Recently, a new form of CVD diamond has been developed: single crystal CVD diamond which resolves many of the issues associated with poly-crystalline CVD material. The first tests of this material are also presented.

  15. Micro-strip sensors based on CVD diamond

    NASA Astrophysics Data System (ADS)

    Adam, W.; Berdermann, E.; Bergonzo, P.; Bertuccio, G.; Bogani, F.; Borchi, E.; Brambilla, A.; Bruzzi, M.; Colledani, C.; Conway, J.; D'Angelo, P.; Dabrowski, W.; Delpierre, P.; Deneuville, A.; Dulinski, W.; van Eijk, B.; Fallou, A.; Fizzotti, F.; Foulon, F.; Friedl, M.; Gan, K. K.; Gheeraert, E.; Hallewell, G.; Han, S.; Hartjes, F.; Hrubec, J.; Husson, D.; Kagan, H.; Kania, D.; Kaplon, J.; Kass, R.; Koeth, T.; Krammer, M.; Logiudice, A.; Lu, R.; mac Lynne, L.; Manfredotti, C.; Meier, D.; Mishina, M.; Moroni, L.; Oh, A.; Pan, L. S.; Pernicka, M.; Peitz, A.; Perera, L.; Pirollo, S.; Procario, M.; Riester, J. L.; Roe, S.; Rousseau, L.; Rudge, A.; Russ, J.; Sala, S.; Sampietro, M.; Schnetzer, S.; Sciortino, S.; Stelzer, H.; Stone, R.; Suter, B.; Tapper, R. J.; Tesarek, R.; Trischuk, W.; Tromson, D.; Vittone, E.; Walsh, A. M.; Wedenig, R.; Weilhammer, P.; Wetstein, M.; White, C.; Zeuner, W.; Zoeller, M.; RD42 Collaboration

    2000-10-01

    In this article we present the performance of recent chemical vapour deposition (CVD) diamond micro-strip sensors in beam tests. In addition, we present the first comparison of a CVD diamond micro-strip sensor before and after proton irradiation.

  16. Numerical Simulations of a 96-rod Polysilicon CVD Reactor

    NASA Astrophysics Data System (ADS)

    Guoqiang, Tang; Cong, Chen; Yifang, Cai; Bing, Zong; Yanguo, Cai; Tihu, Wang

    2018-05-01

    With the rapid development of the photovoltaic industry, pressurized Siemens belljar-type polysilicon CVD reactors have been enlarged from 24 rods to 96 rods in less than 10 years aimed at much greater single-reactor productivity. A CFD model of an industry-scale 96-rod CVD reactor was established to study the internal temperature distribution and the flow field of the reactor. Numerical simulations were carried out and compared with actual growth results from a real CVD reactor. Factors affecting polysilicon depositions such as inlet gas injections, flow field, and temperature distribution in the CVD reactor are studied.

  17. Selected Topics in CVD Diamond Research

    NASA Astrophysics Data System (ADS)

    Koizumi, Satoshi; Nebel, Christoph E.; Nesladek, Milos

    2006-10-01

    Since the discovery of Chemical Vapor Deposition (CVD) diamond growth in 1976, the steady scientific progress often resulted in surprising new discoveries and breakthroughs. This brought us to the idea to publish the special issue Selected Topics in CVD Diamond Research in physica status solidi (a), reflecting such advancements and interesting results at the leading edge of diamond research.The present issue summarizes this progress in the CVD diamond field by selecting contributions from several areas such as superconductivity, super-excitonic radiation, quantum computing, bio-functionalization, surface electronic properties, the nature of phosphorus doping, transport properties in high energy detectors, CVD growth and properties of nanocrystalline diamond. In all these directions CVD diamond appears to be very competitive in comparison with other semiconducting materials.As Editors of this special issue, we must admit that the selection is biased by our opinion. Nonetheless, we are sure that each contribution introduces new ideas and results which will improve the understanding of the current level of physics and chemistry of this attractive wide-bandgap semiconductor and which will help to bring it closer to applications.All submissions were invited based on the contributions of the authors to their specific research field. The Feature Articles have the format of topical reviews to give the reader a comprehensive summary. Partially, however, they are written in research paper style to report new results of ongoing research.We hope that this issue will attract the attention of a broad community of scientists and engineers, and that it will facilitate the utilization of diamond in electronic applications and technologies of the future.

  18. Ion beam figuring of CVD silicon carbide mirrors

    NASA Astrophysics Data System (ADS)

    Gailly, P.; Collette, J.-P.; Fleury Frenette, K.; Jamar, C.

    2017-11-01

    Optical and structural elements made of silicon carbide are increasingly found in space instruments. Chemical vapor deposited silicon carbide (CVD-SiC) is used as a reflective coating on SiC optics in reason of its good behavior under polishing. The advantage of applying ion beam figuring (IBF) to CVD-SiC over other surface figure-improving techniques is discussed herein. The results of an IBF sequence performed at the Centre Spatial de Liège on a 100 mm CVD-SiC mirror are reported. The process allowed to reduce the mirror surface errors from 243 nm to 13 nm rms . Beside the surface figure, roughness is another critical feature to consider in order to preserve the optical quality of CVD-SiC . Thus, experiments focusing on the evolution of roughness were performed in various ion beam etching conditions. The roughness of samples etched at different depths down to 3 ≠m was determined with an optical profilometer. These measurements emphasize the importance of selecting the right combination of gas and beam energy to keep roughness at a low level. Kaufman-type ion sources are generally used to perform IBF but the performance of an end-Hall ion source in figuring CVD-SiC mirrors was also evaluated in this study. In order to do so, ion beam etching profiles obtained with the end-Hall source on CVD-SiC were measured and used as a basis for IBF simulations.

  19. Low-temperature graphene synthesis using microwave plasma CVD

    NASA Astrophysics Data System (ADS)

    Yamada, Takatoshi; Kim, Jaeho; Ishihara, Masatou; Hasegawa, Masataka

    2013-02-01

    The graphene chemical vapour deposition (CVD) technique at substrate temperatures around 300 °C by a microwave plasma sustained by surface waves (surface wave plasma chemical vapour deposition, SWP-CVD) is discussed. A low-temperature, large-area and high-deposition-rate CVD process for graphene films was developed. It was found from Raman spectra that the deposited films on copper (Cu) substrates consisted of high-quality graphene flakes. The fabricated graphene transparent conductive electrode showed uniform optical transmittance and sheet resistance, which suggests the possibility of graphene for practical electrical and optoelectronic applications. It is intriguing that graphene was successfully deposited on aluminium (Al) substrates, for which we did not expect the catalytic effect to decompose hydrocarbon and hydrogen molecules. We developed a roll-to-roll SWP-CVD system for continuous graphene film deposition towards industrial mass production. A pair of winder and unwinder systems of Cu film was installed in the plasma CVD apparatus. Uniform Raman spectra were confirmed over the whole width of 297 mm of Cu films. We successfully transferred the deposited graphene onto PET films, and confirmed a transmittance of about 95% and a sheet resistance of less than 7 × 105 Ω/sq.

  20. Physik gestern und heute Von der Metallstange zum Hochenergielaser

    NASA Astrophysics Data System (ADS)

    Heering, Peter

    2002-05-01

    Im Mai 1752 wurde in Marly bei Paris auf Anregung des amerikanischen Forschers und Politikers Benjamin Franklin erstmals die elektrische Natur des Blitzes nachgewiesen. Damals beschrieb Franklin auch eine technische Vorrichtung, die als Schutz von Gebäuden vor Blitzschlägen dienen sollte: den Blitzableiter. Diese aus heutiger Sicht scheinbar triviale Vorrichtung wurde aber keineswegs unmittelbar akzeptiert. Und bis heute ist die Forschung zum Schutz von Einrichtungen vor Blitzschlägen nicht abgeschlossen.

  1. Iridium-coated rhenium thrusters by CVD

    NASA Technical Reports Server (NTRS)

    Harding, J. T.; Kazaroff, J. M.; Appel, M. A.

    1989-01-01

    Operation of spacecraft thrusters at increased temperature reduces propellant requirements. Inasmuch as propellant comprises the bulk of a satellite's mass, even a small percentage reduction makes possible a significant enhancement of the mission in terms of increased payload. Because of its excellent high temperature strength, rhenium is often the structural material of choice. It can be fabricated into free-standing shapes by chemical vapor deposition (CVD) onto an expendable mandrel. What rhenium lacks is oxidation resistance, but this can be provided by a coating of iridium, also by CVD. This paper describes the process used by Ultramet to fabricate 22-N (5-lbf) and, more recently, 445-N (100-lbf) Ir/Re thrusters; characterizes the CVD-deposited materials; and summarizes the materials effects of firing these thrusters. Optimal propellant mixture ratios can be employed because the materials withstand an oxidizing environment up to the melting temperature of iridium, 2400 C (4350 F).

  2. Iridium-coated rhenium thrusters by CVD

    NASA Technical Reports Server (NTRS)

    Harding, John T.; Kazaroff, John M.; Appel, Marshall A.

    1988-01-01

    Operation of spacecraft thrusters at increased temperature reduces propellant requirements. Inasmuch as propellant comprises the bulk of a satellite's mass, even a small percentage reduction makes possible a significant enhancement of the mission in terms of increased payload. Because of its excellent high temperature strength, rhenium is often the structural material of choice. It can be fabricated into free-standing shapes by chemical vapor deposition (CVD) onto an expendable mandrel. What rhenium lacks is oxidation resistance, but this can be provided by a coating of iridium, also by CVD. This paper describes the process used by Ultramet to fabricate 22-N (5-lbf) and, more recently, 445-N (100-lbf) Ir/Re thrusters; characterizes the CVD-deposited materials; and summarizes the materials effects of firing these thrusters. Optimal propellant mixture ratios can be employed because the materials withstand an oxidizing environment up to the meltimg temperature of iridium, 2400 C (4350 F).

  3. Evaluation of CVD silicon carbide for synchrotron radiation mirrors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Takacs, P.Z.

    1981-07-01

    Chemical vapor deposited silicon carbide (CVD SiC) is a recent addition to the list of materials suitable for use in the harsh environment of synchrotron radiation (SR) beam lines. SR mirrors for use at normal incidence must be ultrahigh vacuum compatible, must withstand intense x-ray irradiation without surface damage, must be capable of being polished to an extremely smooth surface finish, and must maintain surface figure under thermal loading. CVD SiC exceeds the performance of conventional optical materials in all these areas. It is, however, a relatively new optical material. Few manufacturers have experience in producing optical quality material, andmore » few opticians have experience in figuring and polishing the material. The CVD material occurs in a variety of forms, sensitively dependent upon reaction chamber production conditions. We are evaluating samples of CVD SiC obtained commercially from various manufacturers, representing a range of deposition conditions, to determine which types of CVD material are most suitable for superpolishing. At the time of this writing, samples are being polished by several commercial vendors and surface finish characteristics are being evaluated by various analytical methods.« less

  4. Evaluation of CVD silicon carbide for synchrotron radiation mirrors

    NASA Astrophysics Data System (ADS)

    Takacs, Peter Z.

    1982-04-01

    Chemical vapor deposited silicon carbide (CVD SiC) is a recent addition to the list of materials suitable for use in the harsh environment of synchrotron radiation (SR) beam lines. SR mirrors for use at normal incidence must be ultrahigh vacuum compatible, must withstand intense X-ray irradiation without surface damage, must be capable of being polished to an extremely smooth surface finish, and must maintain surface figure under thermal loading. CVD SiC exceeds the performance of conventional optical materials in all these areas. It is, however, a relatively new optical material. Few manufacturers have experience in producing optical quality material, and few opticians have experience in figuring and polishing the material. The CVD material occurs in a variety of forms, sensitively dependent upon reaction chamber production conditions. We are evaluating samples of CVD SiC obtained commercially from various manufacturers, representing a range of deposition conditions, to determine which types of CVD material are most suitable for superpolishing. At the time of this writing, samples are being polished by several commercial vendors and surface finish characteristics are being evaluated by various analytical methods.

  5. Electrical applications of CVD diamond films

    NASA Astrophysics Data System (ADS)

    Fujimori, Naoji

    Electronics applications of CVD diamond films are reported. The properties of epitaxial diamond films are affected by the orientation of the substrate and the deposition conditions. Boron-doped epitaxial films are found to have the same characteristics as natural IIb diamonds. An LED and an FET were successfully fabricated using boron-doped epitaxial films and Schottky junctions. However, these devices did not exhibit satisfactory properties. Other applications of CVD diamond films include speaker diaphragms (as both a thin-film coating and a free-standing film), and as an ideal packaging material (due to its high thermal conductivity and low dielectric constant).

  6. Ballistic Josephson junctions based on CVD graphene

    NASA Astrophysics Data System (ADS)

    Li, Tianyi; Gallop, John; Hao, Ling; Romans, Edward

    2018-04-01

    Josephson junctions with graphene as the weak link between superconductors have been intensely studied in recent years, with respect to both fundamental physics and potential applications. However, most of the previous work was based on mechanically exfoliated graphene, which is not compatible with wafer-scale production. To overcome this limitation, we have used graphene grown by chemical vapour deposition (CVD) as the weak link of Josephson junctions. We demonstrate that very short, wide CVD-graphene-based Josephson junctions with Nb electrodes can work without any undesirable hysteresis in their electrical characteristics from 1.5 K down to a base temperature of 320 mK, and their gate-tuneable critical current shows an ideal Fraunhofer-like interference pattern in a perpendicular magnetic field. Furthermore, for our shortest junctions (50 nm in length), we find that the normal state resistance oscillates with the gate voltage, consistent with the junctions being in the ballistic regime, a feature not previously observed in CVD-graphene-based Josephson junctions.

  7. CVD and obesity in transitional Syria: a perspective from the Middle East.

    PubMed

    Barakat, Hani; Barakat, Hanniya; Baaj, Mohamad K

    2012-01-01

    Syria is caught in the middle of a disruptive nutritional transition. Its healthcare system is distracted by challenges and successes in other areas while neglecting to address the onslaught of Syria's cardiovascular disease (CVD) epidemic. Despite the official viewpoint touting improvement in health indicators, current trends jeopardize population health, and several surveys in the Syrian population signal the epidemic spreading far and wide. The goal is to counteract the indifference towards obesity as a threat to Syrian's health, as the country is slowly becoming a leader in CVD mortality globally. PubMed, World Health Organization, and official government websites were searched for primary surveys in Syria related to CVD morbidity, mortality, and risk factors. Inclusion criteria ensured that results maximized relevance while producing comparable studies. Statistical analysis was applied to detect the most common risk factor and significant differences in risk factor prevalence and CVD rates. Obesity remained the prevailing CVD risk factor except in older Syrian men, where smoking and hypertension were more common. CVD mortality was more common in males due to coronary disease, while stroke dominated female mortality. The young workforce is especially impacted, with 50% of CVD mortality occurring before age 65 years and an 81% prevalence of obesity in women over 45 years. Syria can overcome its slow response to the CVD epidemic and curb further deterioration by reducing obesity and, thus, inheritance and clustering of risk factors. This can be achieved via multilayered awareness and intensive parental and familial involvement. Extinguishing the CVD epidemic is readily achievable as demonstrated in other countries.

  8. A platform for large-scale graphene electronics--CVD growth of single-layer graphene on CVD-grown hexagonal boron nitride.

    PubMed

    Wang, Min; Jang, Sung Kyu; Jang, Won-Jun; Kim, Minwoo; Park, Seong-Yong; Kim, Sang-Woo; Kahng, Se-Jong; Choi, Jae-Young; Ruoff, Rodney S; Song, Young Jae; Lee, Sungjoo

    2013-05-21

    Direct chemical vapor deposition (CVD) growth of single-layer graphene on CVD-grown hexagonal boron nitride (h-BN) film can suggest a large-scale and high-quality graphene/h-BN film hybrid structure with a defect-free interface. This sequentially grown graphene/h-BN film shows better electronic properties than that of graphene/SiO2 or graphene transferred on h-BN film, and suggests a new promising template for graphene device fabrication. Copyright © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  9. Metagenomic study of red biofilms from Diamante Lake reveals ancient arsenic bioenergetics in haloarchaea.

    PubMed

    Rascovan, Nicolás; Maldonado, Javier; Vazquez, Martín P; Eugenia Farías, María

    2016-02-01

    Arsenic metabolism is proposed to be an ancient mechanism in microbial life. Different bacteria and archaea use detoxification processes to grow under high arsenic concentration. Some of them are also able to use arsenic as a bioenergetic substrate in either anaerobic arsenate respiration or chemolithotrophic growth on arsenite. However, among the archaea, bioenergetic arsenic metabolism has only been found in the Crenarchaeota phylum. Here we report the discovery of haloarchaea (Euryarchaeota phylum) biofilms forming under the extreme environmental conditions such as high salinity, pH and arsenic concentration at 4589 m above sea level inside a volcano crater in Diamante Lake, Argentina. Metagenomic analyses revealed a surprisingly high abundance of genes used for arsenite oxidation (aioBA) and respiratory arsenate reduction (arrCBA) suggesting that these haloarchaea use arsenic compounds as bioenergetics substrates. We showed that several haloarchaea species, not only from this study, have all genes required for these bioenergetic processes. The phylogenetic analysis of aioA showed that haloarchaea sequences cluster in a novel and monophyletic group, suggesting that the origin of arsenic metabolism in haloarchaea is ancient. Our results also suggest that arsenite chemolithotrophy likely emerged within the archaeal lineage. Our results give a broad new perspective on the haloarchaea metabolism and shed light on the evolutionary history of arsenic bioenergetics.

  10. CVD and obesity in transitional Syria: a perspective from the Middle East

    PubMed Central

    Barakat, Hani; Barakat, Hanniya; Baaj, Mohamad K

    2012-01-01

    Purpose Syria is caught in the middle of a disruptive nutritional transition. Its healthcare system is distracted by challenges and successes in other areas while neglecting to address the onslaught of Syria’s cardiovascular disease (CVD) epidemic. Despite the official viewpoint touting improvement in health indicators, current trends jeopardize population health, and several surveys in the Syrian population signal the epidemic spreading far and wide. The goal is to counteract the indifference towards obesity as a threat to Syrian’s health, as the country is slowly becoming a leader in CVD mortality globally. Methods PubMed, World Health Organization, and official government websites were searched for primary surveys in Syria related to CVD morbidity, mortality, and risk factors. Inclusion criteria ensured that results maximized relevance while producing comparable studies. Statistical analysis was applied to detect the most common risk factor and significant differences in risk factor prevalence and CVD rates. Results Obesity remained the prevailing CVD risk factor except in older Syrian men, where smoking and hypertension were more common. CVD mortality was more common in males due to coronary disease, while stroke dominated female mortality. The young workforce is especially impacted, with 50% of CVD mortality occurring before age 65 years and an 81% prevalence of obesity in women over 45 years. Conclusion Syria can overcome its slow response to the CVD epidemic and curb further deterioration by reducing obesity and, thus, inheritance and clustering of risk factors. This can be achieved via multilayered awareness and intensive parental and familial involvement. Extinguishing the CVD epidemic is readily achievable as demonstrated in other countries. PMID:22454558

  11. Layered hydrothermal barite-sulfide mound field, East Diamante Caldera, Mariana volcanic arc

    USGS Publications Warehouse

    Hein, James R.; de Ronde, Cornel E. J.; Koski, Randolph A.; Ditchburn, Robert G.; Mizell, Kira; Tamura, Yoshihiko; Stern, Robert J.; Conrad, Tracey; Ishizuka, Osamu; Leybourne, Matthew I.

    2014-01-01

    East Diamante is a submarine volcano in the southern Mariana arc that is host to a complex caldera ~5 × 10 km (elongated ENE-WSW) that is breached along its northern and southwestern sectors. A large field of barite-sulfide mounds was discovered in June 2009 and revisited in July 2010 with the R/V Natsushima, using the ROV Hyper-Dolphin. The mound field occurs on the northeast flank of a cluster of resurgent dacite domes in the central caldera, near an active black smoker vent field. A 40Ar/39Ar age of 20,000 ± 4000 years was obtained from a dacite sample. The mound field is aligned along a series of fractures and extends for more than 180 m east-west and >120 m north-south. Individual mounds are typically 1 to 3 m tall and 0.5 to 2 m wide, with lengths from about 3 to 8 m. The mounds are dominated by barite + sphalerite layers with the margins of each layer composed of barite with disseminated sulfides. Rare, inactive spires and chimneys sit atop some mounds and also occur as clusters away from the mounds. Iron and Mn oxides are currently forming small (<1-m diam, ~0.5-m tall) knolls on the top surface of some of the barite-sulfide mounds and may also drape their flanks. Both diffusely and focused fluids emanate from the small oxide knolls. Radiometric ages of the layered barite-sulfide mounds and chimneys vary from ~3,920 to 3,350 years. One layer, from an outcrop of 10- to 100-cm-thick Cu-rich layers, is notably younger with an age of 2,180 years. The Fe-Mn oxides were <5 years old at the time of collection in 2009.Most mound, chimney, and layered outcrop samples are dominated by barite, silica, and sphalerite; other sulfides, in decreasing order of abundance, are galena, chalcopyrite, and rare pyrite. Anglesite, cerussite, and unidentified Pb oxychloride and Pb phosphate minerals occur as late-stage interstitial phases. The samples contain high Zn (up to 23 wt %), Pb (to 16 wt %), Ag (to 487 ppm), and Au (to 19 ppm) contents. Some layered outcrop samples

  12. Validation of a model to investigate the effects of modifying cardiovascular disease (CVD) risk factors on the burden of CVD: the rotterdam ischemic heart disease and stroke computer simulation (RISC) model.

    PubMed

    van Kempen, Bob J H; Ferket, Bart S; Hofman, Albert; Steyerberg, Ewout W; Colkesen, Ersen B; Boekholdt, S Matthijs; Wareham, Nicholas J; Khaw, Kay-Tee; Hunink, M G Myriam

    2012-12-06

    We developed a Monte Carlo Markov model designed to investigate the effects of modifying cardiovascular disease (CVD) risk factors on the burden of CVD. Internal, predictive, and external validity of the model have not yet been established. The Rotterdam Ischemic Heart Disease and Stroke Computer Simulation (RISC) model was developed using data covering 5 years of follow-up from the Rotterdam Study. To prove 1) internal and 2) predictive validity, the incidences of coronary heart disease (CHD), stroke, CVD death, and non-CVD death simulated by the model over a 13-year period were compared with those recorded for 3,478 participants in the Rotterdam Study with at least 13 years of follow-up. 3) External validity was verified using 10 years of follow-up data from the European Prospective Investigation of Cancer (EPIC)-Norfolk study of 25,492 participants, for whom CVD and non-CVD mortality was compared. At year 5, the observed incidences (with simulated incidences in brackets) of CHD, stroke, and CVD and non-CVD mortality for the 3,478 Rotterdam Study participants were 5.30% (4.68%), 3.60% (3.23%), 4.70% (4.80%), and 7.50% (7.96%), respectively. At year 13, these percentages were 10.60% (10.91%), 9.90% (9.13%), 14.20% (15.12%), and 24.30% (23.42%). After recalibrating the model for the EPIC-Norfolk population, the 10-year observed (simulated) incidences of CVD and non-CVD mortality were 3.70% (4.95%) and 6.50% (6.29%). All observed incidences fell well within the 95% credibility intervals of the simulated incidences. We have confirmed the internal, predictive, and external validity of the RISC model. These findings provide a basis for analyzing the effects of modifying cardiovascular disease risk factors on the burden of CVD with the RISC model.

  13. Mixed Convection Flow in Horizontal CVD Reactors

    NASA Astrophysics Data System (ADS)

    Chiu, Wilson K. S.; Richards, Cristy J.; Jaluria, Yogesh

    1998-11-01

    Increasing demands for high quality films and production rates are challenging current Chemical Vapor Deposition (CVD) technology. Since film quality and deposition rates are strongly dependent on gas flow and heat transfer (W.K.S. Chiu and Y. Jaluria, ASME HTD-Vol. 347, pp. 293-311, 1997.), process improvement is obtained through the study of mixed convection flow and temperature distribution in a CVD reactor. Experimental results are presented for a CVD chamber with a horizontal or inclined resistance heated susceptor. Vaporized glycol solution illuminated by a light sheet is used for flow visualization. Temperature measurements are obtained by inserting thermocouple probes into the gas stream or embedding probes into the reactor walls. Flow visualization and temperature measurements show predominantly two dimensional flow and temperature distributions along the streamwise direction under forced convection conditions. Natural convection dominates under large heating rates and low flow rates. Over the range of parameters studied, several distinct flow regimes, characterized by instability, separation, and turbulence, are evident. Different flow regimes alter the flow pattern and temperature distribution, and in consequence, significantly modify deposition rates and uniformity.

  14. Recent results on CVD diamond radiation sensors

    NASA Astrophysics Data System (ADS)

    Weilhammer, P.; Adam, W.; Bauer, C.; Berdermann, E.; Bogani, F.; Borchi, E.; Bruzzi, M.; Colledani, C.; Conway, J.; Dabrowski, W.; Delpierre, P.; Deneuville, A.; Dulinski, W.; v. d. Eijk, R.; van Eijk, B.; Fallou, A.; Fish, D.; Fried, M.; Gan, K. K.; Gheeraert, E.; Grigoriev, E.; Hallewell, G.; Hall-Wilton, R.; Han, S.; Hartjes, F.; Hrubec, J.; Husson, D.; Kagan, H.; Kania, D.; Kaplon, J.; Kass, R.; Knopfle, K. T.; Krammer, M.; Manfredi, P. F.; Meier, D.; LeNormand; Pan, L. S.; Pernegger, H.; Pernicka, M.; Plano, R.; Re, V.; Riester, J. L.; Roe, S.; Roff; Rudge, A.; Schieber, M.; Schnetzer, S.; Sciortino, S.; Speziali, V.; Stelzer, H.; Stone, R.; Tapper, R. J.; Tesarek, R.; Thomson, G. B.; Trawick, M.; Trischuk, W.; Turchetta, R.; RD 42 Collaboration

    1998-02-01

    CVD diamond radiation sensors are being developed for possible use in trackers in the LHC experiments. The diamond promises to be radiation hard well beyond particle fluences that can be tolerated by Si sensors. Recent results from the RD 42 collaboration on charge collection distance and on radiation hardness of CVD diamond samples will be reported. Measurements with diamond tracking devices, both strip detectors and pixel detectors, will be discussed. Results from beam tests using a diamond strip detector which was read out with fast, 25 ns shaping time, radiation-hard pipeline electronics will be presented.

  15. Recent Results with CVD Diamond Trackers

    NASA Astrophysics Data System (ADS)

    Adam, W.; Bauer, C.; Berdermann, E.; Bergonzo, P.; Bogani, F.; Borchi, E.; Brambilla, A.; Bruzzi, M.; Colledani, C.; Conway, J.; Dabrowski, W.; Delpierre, P.; Deneuville, A.; Dulinski, W.; van Eijk, B.; Fallou, A.; Fizzotti, F.; Foulon, F.; Friedl, M.; Gan, K. K.; Gheeraert, E.; Grigoriev, E.; Hallewell, G.; Hall-Wilton, R.; Han, S.; Hartjes, F.; Hrubec, J.; Husson, D.; Kagan, H.; Kania, D.; Kaplon, J.; Karl, C.; Kass, R.; Knöpfle, K. T.; Krammer, M.; Logiudice, A.; Lu, R.; Manfredi, P. F.; Manfredotti, C.; Marshall, R. D.; Meier, D.; Mishina, M.; Oh, A.; Pan, L. S.; Palmieri, V. G.; Pernicka, M.; Peitz, A.; Pirollo, S.; Polesello, P.; Pretzl, K.; Procario, M.; Re, V.; Riester, J. L.; Roe, S.; Roff, D.; Rudge, A.; Runolfsson, O.; Russ, J.; Schnetzer, S.; Sciortino, S.; Speziali, V.; Stelzer, H.; Stone, R.; Suter, B.; Tapper, R. J.; Tesarek, R.; Trawick, M.; Trischuk, W.; Vittone, E.; Walsh, A. M.; Wedenig, R.; Weilhammer, P.; White, C.; Ziock, H.; Zoeller, M.; RD42 Collaboration

    1999-08-01

    We present recent results on the use of Chemical Vapor Deposition (CVD) diamond microstrip detectors for charged particle tracking. A series of detectors was fabricated using 1 x 1 cm 2 diamonds. Good signal-to-noise ratios were observed using both slow and fast readout electronics. For slow readout electronics, 2 μs shaping time, the most probable signal-to-noise ratio was 50 to 1. For fast readout electronics, 25 ns peaking time, the most probable signal-to-noise ratio was 7 to 1. Using the first 2 x 4 cm 2 diamond from a production CVD reactor with slow readout electronics, the most probable signal-to-noise ratio was 23 to 1. The spatial resolution achieved for the detectors was consistent with the digital resolution expected from the detector pitch.

  16. Friction Properties of Polished Cvd Diamond Films Sliding against Different Metals

    NASA Astrophysics Data System (ADS)

    Lin, Zichao; Sun, Fanghong; Shen, Bin

    2016-11-01

    Owing to their excellent mechanical and tribological properties, like the well-known extreme hardness, low coefficient of friction and high chemical inertness, chemical vapor deposition (CVD) diamond films have found applications as a hard coating for drawing dies. The surface roughness of the diamond films is one of the most important attributes to the drawing dies. In this paper, the effects of different surface roughnesses on the friction properties of diamond films have been experimentally studied. Diamond films were fabricated using hot filament CVD. The WC-Co (Co 6wt.%) drawing dies were used as substrates. A gas mixture of acetone and hydrogen gas was used as the feedstock gas. The CVD diamond films were polished using mechanical polishing. Polished diamond films with three different surface roughnesses, as well as the unpolished diamond film, were fabricated in order to study the tribological performance between the CVD diamond films and different metals with oil lubrication. The unpolished and polished CVD diamond films are characterized with scanning electron microscope (SEM), atomic force microscope (AFM), surface profilometer, Raman spectrum and X-ray diffraction (XRD). The friction examinations were carried out by using a ball-on-plate type reciprocating friction tester. Low carbide steel, stainless steel, copper and aluminum materials were used as counterpart balls. Based on this study, the results presented the friction coefficients between the polished CVD films and different metals. The friction tests demonstrate that the smooth surface finish of CVD diamond films is beneficial for reducing their friction coefficients. The diamond films exhibit low friction coefficients when slid against the stainless steel balls and low carbide steel ball, lower than that slid against copper ball and aluminum ball, attributed to the higher ductility of copper and aluminum causing larger amount of wear debris adhering to the sliding interface and higher adhesive

  17. Fibrinogen concentration and its role in CVD risk in black South Africans--effect of urbanisation.

    PubMed

    Pieters, Marlien; de Maat, Moniek P M; Jerling, Johann C; Hoekstra, Tiny; Kruger, Annamarie

    2011-09-01

    The aim of this study was to investigate correlates of fibrinogen concentration in black South Africans, as well as its association with cardiovascular disease (CVD) risk and whether urbanisation influences this association. A total of 1,006 rural and 1,004 urban black South Africans from the PURE study were cross-sectionally analysed. The association of fibrinogen with CVD risk was determined by investigating the association of fibrinogen with other CVD risk markers as well as with predicted CVD risk using the Reynolds Risk score. The rural group had a significantly higher fibrinogen concentration than the urban group, despite higher levels of risk factors and increased predicted CVD risk in the urban group. Increased levels of CVD risk factors were, however, still associated with increased fibrinogen concentration. Fibrinogen correlated significantly, but weakly, with overall predicted CVD risk. This correlation was stronger in the urban than in the rural group. Multiple regression analysis showed that a smaller percentage of the variance in fibrinogen is explained by the traditional CVD risk factors in the rural than in the urban group. In conclusion, fibrinogen is weakly associated with CVD risk (predicted overall risk as well with individual risk factors) in black South Africans, and is related to the degree of urbanisation. Increased fibrinogen concentration, in black South Africans, especially in rural areas, is largely unexplained, and likely not strongly correlated with traditional CVD-related lifestyle and pathophysiological processes. This does, however, not exclude the possibility that once increased, the fibrinogen concentration contributes to future development of CVD.

  18. Surface structuring of boron doped CVD diamond by micro electrical discharge machining

    NASA Astrophysics Data System (ADS)

    Schubert, A.; Berger, T.; Martin, A.; Hackert-Oschätzchen, M.; Treffkorn, N.; Kühn, R.

    2018-05-01

    Boron doped diamond materials, which are generated by Chemical Vapor Deposition (CVD), offer a great potential for the application on highly stressed tools, e. g. in cutting or forming processes. As a result of the CVD process rough surfaces arise, which require a finishing treatment in particular for the application in forming tools. Cutting techniques such as milling and grinding are hardly applicable for the finish machining because of the high strength of diamond. Due to its process principle of ablating material by melting and evaporating, Electrical Discharge Machining (EDM) is independent of hardness, brittleness or toughness of the workpiece material. EDM is a suitable technology for machining and structuring CVD diamond, since boron doped CVD diamond is electrically conductive. In this study the ablation characteristics of boron doped CVD diamond by micro electrical discharge machining are investigated. Experiments were carried out to investigate the influence of different process parameters on the machining result. The impact of tool-polarity, voltage and discharge energy on the resulting erosion geometry and the tool wear was analyzed. A variation in path overlapping during the erosion of planar areas leads to different microstructures. The results show that micro EDM is a suitable technology for finishing of boron doped CVD diamond.

  19. Deposition and micro electrical discharge machining of CVD-diamond layers incorporated with silicon

    NASA Astrophysics Data System (ADS)

    Kühn, R.; Berger, T.; Prieske, M.; Börner, R.; Hackert-Oschätzchen, M.; Zeidler, H.; Schubert, A.

    2017-10-01

    In metal forming, lubricants have to be used to prevent corrosion or to reduce friction and tool wear. From an economical and ecological point of view, the aim is to avoid the usage of lubricants. For dry deep drawing of aluminum sheets it is intended to apply locally micro-structured wear-resistant carbon based coatings onto steel tools. One type of these coatings are diamond layers prepared by chemical vapor deposition (CVD). Due to the high strength of diamond, milling processes are unsuitable for micro-structuring of these layers. In contrast to this, micro electrical discharge machining (micro EDM) is a suitable process for micro-structuring CVD-diamond layers. Due to its non-contact nature and its process principle of ablating material by melting and evaporating, it is independent of the hardness, brittleness or toughness of the workpiece material. In this study the deposition and micro electrical discharge machining of silicon incorporated CVD-diamond (Si-CVD-diamond) layers were presented. For this, 10 µm thick layers were deposited on molybdenum plates by a laser-induced plasma CVD process (LaPlas-CVD). For the characterization of the coatings RAMAN- and EDX-analyses were conducted. Experiments in EDM were carried out with a tungsten carbide tool electrode with a diameter of 90 µm to investigate the micro-structuring of Si-CVD-diamond. The impact of voltage, discharge energy and tool polarity on process speed and resulting erosion geometry were analyzed. The results show that micro EDM is a suitable technology for micro-structuring of silicon incorporated CVD-diamond layers.

  20. NEXAFS Study of the Annealing Effect on the Local Structure of FIB-CVD DLC

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Saikubo, Akihiko; Kato, Yuri; Igaki, Jun-ya

    2007-01-19

    Annealing effect on the local structure of diamond like carbon (DLC) formed by focused ion beam-chemical vapor deposition (FIB-CVD) was investigated by the measurement of near edge x-ray absorption fine structure (NEXAFS) and energy dispersive x-ray (EDX) spectra. Carbon K edge absorption NEXAFS spectrum of FIB-CVD DLC was measured in the energy range of 275-320 eV. In order to obtain the information on the location of the gallium in the depth direction, incidence angle dependence of NEXAFS spectrum was measured in the incident angle range from 0 deg. to 60 deg. . The peak intensity corresponding to the resonance transitionmore » of 1s{yields}{sigma}* originating from carbon-gallium increased from the FIB-CVD DLC annealed at 200 deg. C to the FIB-CVD DLC annealed at 400 deg. C and decreased from that at 400 deg. C to that at 600 deg. C. Especially, the intensity of this peak remarkably enhanced in the NEXAFS spectrum of the FIB-CVD DLC annealed at 400 deg. C at the incident angle of 60 deg. . On the contrary, the peak intensity corresponding to the resonance transition of 1s{yields}{pi}* originating from carbon double bonding of emission spectrum decreased from the FIB-CVD DLC annealed at 200 deg. C to that at 400 deg. C and increased from that at 400 deg. C to that at 600 deg. C. Gallium concentration in the FIB-CVD DLC decreased from {approx_equal}2.2% of the as-deposited FIB-CVD DLC to {approx_equal}1.5% of the FIB-CVD DLC annealed at 600 deg. C from the elementary analysis using EDX. Both experimental results indicated that gallium atom departed from FIB-CVD DLC by annealing at the temperature of 600 deg. C.« less

  1. Risks of restrictive red blood cell transfusion strategies in patients with cardiovascular disease (CVD): a meta-analysis.

    PubMed

    Cortés-Puch, I; Wiley, B M; Sun, J; Klein, H G; Welsh, J; Danner, R L; Eichacker, P Q; Natanson, C

    2018-04-19

    To evaluate the risks of restrictive red blood cell transfusion strategies (haemoglobin 7-8 g dL -1 ) in patients with and without known cardiovascular disease (CVD). Recent guidelines recommend restrictive strategies for CVD patients hospitalised for non-CVD indications, patients without known CVD and patients hospitalised for CVD corrective procedures. Database searches were conducted through December 2017 for randomised clinical trials that enrolled patients with and without known CVD, hospitalised either for CVD-corrective procedures or non-cardiac indications, comparing effects of liberal with restrictive strategies on major adverse coronary events (MACE) and death. In CVD patients not undergoing cardiac interventions, a liberal strategy decreased (P = 0·01) the relative risk (95% CI) (RR) of MACE [0·50 (0·29-0·86)] (I 2  = 0%). Among patients without known CVD, the incidence of MACE was lower (1·7 vs 3·9%), and the effect of a liberal strategy on MACE [0·79, (0·39-1·58)] was smaller and non-significant but not different from CVD patients (P = 0·30). Combining all CVD and non-CVD patients, a liberal strategy decreased MACE [0·59, (0·39-0·91); P = 0·02]. Conversely, among studies reporting mortality, a liberal strategy decreased mortality in CVD patients (11·7% vs·13·3%) but increased mortality (19·2% vs 18·0%) in patients without known CVD [interaction P = 0·05; ratio of RR 0·73, (0·53-1·00)]. A liberal strategy also did not benefit patients undergoing cardiac surgery; data were insufficient for percutaneous cardiac procedures. In patients hospitalised for non-cardiac indications, liberal transfusion strategies are associated with a decreased risk of MACE in both those with and without known CVD. However, this only provides a survival benefit to CVD patients not admitted for CVD-corrective procedures. © 2018 British Blood Transfusion Society.

  2. Development of CVD mullite coatings for Si-based ceramics

    NASA Astrophysics Data System (ADS)

    Auger, Michael Lawrence

    1999-09-01

    To raise fuel efficiencies, the next generation of engines and fuel systems must be lighter and operate at higher temperatures. Ceramic-based materials, which are considerably lighter than metals and can withstand working temperatures of up to 1400sp°C, have been targeted to replace traditional metal-based components. The materials used in combustion environments must also be capable of withstanding erosion and corrosion caused by combustion gases, particulates, and deposit-forming corrodants. With these demanding criteria, silicon-based ceramics are the leading candidate materials for high temperature engine and heat exchanger structural components. However, these materials are limited in gaseous environments and in the presence of molten salts since they form liquid silicates on exposed surfaces at temperatures as low as 800sp°C. Protective coatings that can withstand higher operating temperatures and corrosive atmospheres must be developed for silicon-based ceramics. Mullite (3Alsb2Osb3{*}2SiOsb2) was targeted as a potential coating material due to its unique ability to resist corrosion, retain its strength, resist creep, and avoid thermal shock failure at elevated temperatures. Several attempts to deposit mullite coatings by various processing methods have met with limited success and usually resulted in coatings that have had pores, cracks, poor adherence, and required thermal post-treatments. To overcome these deficiencies, the direct formation of chemically vapor deposited (CVD) mullite coatings has been developed. CVD is a high temperature atomistic deposition technique that results in dense, adherent crystalline coatings. The object of this dissertation was to further the understanding of the CVD mullite deposition process and resultant coating. The kinetics of CVD mullite deposition were investigated as a function of the following process parameters: temperature, pressure, and the deposition reactor system. An empirical kinetic model was developed

  3. Nuts and CVD.

    PubMed

    Ros, Emilio

    2015-04-01

    Nuts are nutrient-dense foods with complex matrices rich in unsaturated fatty acids and other bioactive compounds, such as l-arginine, fibre, healthful minerals, vitamin E, phytosterols and polyphenols. By virtue of their unique composition, nuts are likely to beneficially affect cardiovascular health. Epidemiological studies have associated nut consumption with a reduced incidence of CHD in both sexes and of diabetes in women, but not in men. Feeding trials have clearly demonstrated that consumption of all kinds of nuts has a cholesterol-lowering effect, even in the context of healthy diets. There is increasing evidence that nut consumption has a beneficial effect on oxidative stress, inflammation and vascular reactivity. Blood pressure, visceral adiposity and the metabolic syndrome also appear to be positively influenced by nut consumption. Contrary to expectations, epidemiological studies and clinical trials suggest that regular nut consumption is not associated with undue weight gain. Recently, the PREvención con DIeta MEDiterránea randomised clinical trial of long-term nutrition intervention in subjects at high cardiovascular risk provided first-class evidence that regular nut consumption is associated with a 50 % reduction in incident diabetes and, more importantly, a 30 % reduction in CVD. Of note, incident stroke was reduced by nearly 50 % in participants allocated to a Mediterranean diet enriched with a daily serving of mixed nuts (15 g walnuts, 7.5 g almonds and 7.5 g hazelnuts). Thus, it is clear that frequent nut consumption has a beneficial effect on CVD risk that is likely to be mediated by salutary effects on intermediate risk factors.

  4. CVD facility electrical system captor/dapper study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    SINGH, G.

    1999-10-28

    Project W-441, CVD Facility Electrical System CAPTOWDAPPER Study validates Meier's hand calculations. This study includes Load flow, short circuit, voltage drop, protective device coordination, and transient motor starting (TMS) analyses.

  5. Flavonoids and Reduction of Cardiovascular Disease (CVD) in Chronic Obstructive Pulmonary Disease (COPD).

    PubMed

    Russo, Patrizia; Prinzi, Giulia; Lamonaca, Palma; Cardaci, Vittorio; Fini, Massimo

    2018-05-13

    Chronic obstructive pulmonary disease (COPD) and cardiovascular diseases (CV) often coexist. COPD and CVD are complex diseases characterized by a strict interaction between environment and genetic. The mechanisms linking these two diseases are complex, multifactorial and not entirely understood, influencing the therapeutic approach. COPD is characterized by several comorbidities, it is hypothesizable that treatment of cardiovascular co-morbidities may reduce morbidity and mortality. Flavonoids are an important class of plant low molecular weight secondary metabolites (SMs). Convincing data from laboratory, epidemiological, and human clinical studies point to an important effects on CVD risk prevention. This review aims to provide up-to-date information on the ability of Flavonoids to reduce the CVD risk. Current studies support the potential of Flavonoids to prevent the risk of CVD. Well-designed clinical studies are suggested to evaluate advantages and limits of Flavonoids for managing CVD comorbidity in COPD. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  6. Evaluation of infrared thermography as a diagnostic tool in CVD applications

    NASA Astrophysics Data System (ADS)

    Johnson, E. J.; Hyer, P. V.; Culotta, P. W.; Clark, I. O.

    1998-05-01

    This research is focused on the feasibility of using infrared temperature measurements on the exterior of a chemical vapor deposition (CVD) reactor to ascertain both real-time information on the operating characteristics of a CVD system and provide data which could be post-processed to provide quantitative information for research and development on CVD processes. Infrared thermography techniques were used to measure temperatures on a horizontal CVD reactor of rectangular cross section which were correlated with the internal gas flow field, as measured with the laser velocimetry (LV) techniques. For the reactor tested, thermal profiles were well correlated with the gas flow field inside the reactor. Correlations are presented for nitrogen and hydrogen carrier gas flows. The infrared data were available to the operators in real time with sufficient sensitivity to the internal flow field so that small variations such as misalignment of the reactor inlet could be observed. The same data were post-processed to yield temperature measurements at known locations on the reactor surface. For the experiments described herein, temperatures associated with approximately 3.3 mm 2 areas on the reactor surface were obtained with a precision of ±2°C. These temperature measurements were well suited for monitoring a CVD production reactor, development of improved thermal boundary conditions for use in CFD models of reactors, and for verification of expected thermal conditions.

  7. Dietary Choline and Betaine and Risk of CVD: A Systematic Review and Meta-Analysis of Prospective Studies

    PubMed Central

    Meyer, Katie A.; Shea, Jonathan W.

    2017-01-01

    Studies implicate choline and betaine metabolite trimethylamine N-oxide (TMAO) in cardiovascular disease (CVD). We conducted a systematic review and random-effects meta-analysis to quantify a summary estimated effect of dietary choline and betaine on hard CVD outcomes (incidence and mortality). Eligible studies were prospective studies in adults with comprehensive diet assessment and follow-up for hard CVD endpoints. We identified six studies that met our criteria, comprising 18,076 incident CVD events, 5343 CVD deaths, and 184,010 total participants. In random effects meta-analysis, incident CVD was not associated with choline (relative risk (RR): 1.00; 95% CI: 0.98, 1.02) or betaine (RR: 0.99; 95% CI: 0.98, 1.01) intake. Results did not vary by study outcome (incident coronary heart disease, stroke, total CVD) and there was no evidence for heterogeneity among studies. Only two studies provided data on phosphatidylcholine and CVD mortality. Random effects meta-analysis did not support an association between choline and CVD mortality (RR: 1.09, 95% CI: 0.89, 1.35), but one study supported a positive association and there was significant heterogeneity (I2 = 84%, p-value < 0.001). Our findings do not support an association between dietary choline/betaine with incident CVD, but call for further research into choline and CVD mortality. PMID:28686188

  8. Dietary Choline and Betaine and Risk of CVD: A Systematic Review and Meta-Analysis of Prospective Studies.

    PubMed

    Meyer, Katie A; Shea, Jonathan W

    2017-07-07

    Studies implicate choline and betaine metabolite trimethylamine N-oxide (TMAO) in cardiovascular disease (CVD). We conducted a systematic review and random-effects meta-analysis to quantify a summary estimated effect of dietary choline and betaine on hard CVD outcomes (incidence and mortality). Eligible studies were prospective studies in adults with comprehensive diet assessment and follow-up for hard CVD endpoints. We identified six studies that met our criteria, comprising 18,076 incident CVD events, 5343 CVD deaths, and 184,010 total participants. In random effects meta-analysis, incident CVD was not associated with choline (relative risk (RR): 1.00; 95% CI: 0.98, 1.02) or betaine (RR: 0.99; 95% CI: 0.98, 1.01) intake. Results did not vary by study outcome (incident coronary heart disease, stroke, total CVD) and there was no evidence for heterogeneity among studies. Only two studies provided data on phosphatidylcholine and CVD mortality. Random effects meta-analysis did not support an association between choline and CVD mortality (RR: 1.09, 95% CI: 0.89, 1.35), but one study supported a positive association and there was significant heterogeneity ( I ² = 84%, p -value < 0.001). Our findings do not support an association between dietary choline/betaine with incident CVD, but call for further research into choline and CVD mortality.

  9. Defining the relationship between COPD and CVD: what are the implications for clinical practice?

    PubMed Central

    Morgan, Ann D; Zakeri, Rosita; Quint, Jennifer K

    2018-01-01

    Cardiovascular diseases (CVDs) are arguably the most important comorbidities in chronic obstructive pulmonary disease (COPD). CVDs are common in people with COPD, and their presence is associated with increased risk for hospitalization, longer length of stay and all-cause and CVD-related mortality. The economic burden associated with CVD in this population is considerable and the cumulative cost of treating comorbidities may even exceed that of treating COPD itself. Our understanding of the biological mechanisms that link COPD and various forms of CVD has improved significantly over the past decade. But despite broad acceptance of the prognostic significance of CVDs in COPD, there remains widespread under-recognition and undertreatment of comorbid CVD in this population. The reasons for this are unclear; however institutional barriers and a lack of evidence-based guidelines for the management of CVD in people with COPD may be contributory factors. In this review, we summarize current knowledge relating to the prevalence and incidence of CVD in people with COPD and the mechanisms that underlie their coexistence. We discuss the implications for clinical practice and highlight opportunities for improved prevention and treatment of CVD in people with COPD. While we advocate more active assessment for signs of cardiovascular conditions across all age groups and all stages of COPD severity, we suggest targeting those aged under 65 years. Evidence indicates that the increased risks for CVD are particularly pronounced in COPD patients in mid-to-late-middle-age and thus it is in this age group that the benefits of early intervention may prove to be the most effective. PMID:29355081

  10. CVD-Enabled Graphene Manufacture and Technology

    PubMed Central

    2015-01-01

    Integrated manufacturing is arguably the most challenging task in the development of technology based on graphene and other 2D materials, particularly with regard to the industrial demand for “electronic-grade” large-area films. In order to control the structure and properties of these materials at the monolayer level, their nucleation, growth and interfacing needs to be understood to a level of unprecedented detail compared to existing thin film or bulk materials. Chemical vapor deposition (CVD) has emerged as the most versatile and promising technique to develop graphene and 2D material films into industrial device materials and this Perspective outlines recent progress, trends, and emerging CVD processing pathways. A key focus is the emerging understanding of the underlying growth mechanisms, in particular on the role of the required catalytic growth substrate, which brings together the latest progress in the fields of heterogeneous catalysis and classic crystal/thin-film growth. PMID:26240694

  11. Delaminated Transfer of CVD Graphene

    NASA Astrophysics Data System (ADS)

    Clavijo, Alexis; Mao, Jinhai; Tilak, Nikhil; Altvater, Michael; Andrei, Eva

    Single layer graphene is commonly synthesized by dissociation of a carbonaceous gas at high temperatures in the presence of a metallic catalyst in a process known as Chemical Vapor Deposition or CVD. Although it is possible to achieve high quality graphene by CVD, the standard transfer technique of etching away the metallic catalyst is wasteful and jeopardizes the quality of the graphene film by contamination from etchants. Thus, development of a clean transfer technique and preservation of the parent substrate remain prominent hurdles to overcome. In this study, we employ a copper pretreatment technique and optimized parameters for growth of high quality single layer graphene at atmospheric pressure. We address the transfer challenge by utilizing the adhesive properties between a polymer film and graphene to achieve etchant-free transfer of graphene films from a copper substrate. Based on this concept we developed a technique for dry delamination and transferring of graphene to hexagonal boron nitride substrates, which produced high quality graphene films while at the same time preserving the integrity of the copper catalyst for reuse. DOE-FG02-99ER45742, Ronald E. McNair Postbaccalaureate Achievement Program.

  12. 25th anniversary article: CVD polymers: a new paradigm for surface modification and device fabrication.

    PubMed

    Coclite, Anna Maria; Howden, Rachel M; Borrelli, David C; Petruczok, Christy D; Yang, Rong; Yagüe, Jose Luis; Ugur, Asli; Chen, Nan; Lee, Sunghwan; Jo, Won Jun; Liu, Andong; Wang, Xiaoxue; Gleason, Karen K

    2013-10-11

    Well-adhered, conformal, thin (<100 nm) coatings can easily be obtained by chemical vapor deposition (CVD) for a variety of technological applications. Room temperature modification with functional polymers can be achieved on virtually any substrate: organic, inorganic, rigid, flexible, planar, three-dimensional, dense, or porous. In CVD polymerization, the monomer(s) are delivered to the surface through the vapor phase and then undergo simultaneous polymerization and thin film formation. By eliminating the need to dissolve macromolecules, CVD enables insoluble polymers to be coated and prevents solvent damage to the substrate. CVD film growth proceeds from the substrate up, allowing for interfacial engineering, real-time monitoring, and thickness control. Initiated-CVD shows successful results in terms of rationally designed micro- and nanoengineered materials to control molecular interactions at material surfaces. The success of oxidative-CVD is mainly demonstrated for the deposition of organic conducting and semiconducting polymers. Copyright © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  13. Investigation of multilayer domains in large-scale CVD monolayer graphene by optical imaging

    NASA Astrophysics Data System (ADS)

    Yu, Yuanfang; Li, Zhenzhen; Wang, Wenhui; Guo, Xitao; Jiang, Jie; Nan, Haiyan; Ni, Zhenhua

    2017-03-01

    CVD graphene is a promising candidate for optoelectronic applications due to its high quality and high yield. However, multi-layer domains could inevitably form at the nucleation centers during the growth. Here, we propose an optical imaging technique to precisely identify the multilayer domains and also the ratio of their coverage in large-scale CVD monolayer graphene. We have also shown that the stacking disorder in twisted bilayer graphene as well as the impurities on the graphene surface could be distinguished by optical imaging. Finally, we investigated the effects of bilayer domains on the optical and electrical properties of CVD graphene, and found that the carrier mobility of CVD graphene is seriously limited by scattering from bilayer domains. Our results could be useful for guiding future optoelectronic applications of large-scale CVD graphene. Project supported by the National Natural Science Foundation of China (Nos. 61422503, 61376104), the Open Research Funds of Key Laboratory of MEMS of Ministry of Education (SEU, China), and the Fundamental Research Funds for the Central Universities.

  14. CVD2014-A Database for Evaluating No-Reference Video Quality Assessment Algorithms.

    PubMed

    Nuutinen, Mikko; Virtanen, Toni; Vaahteranoksa, Mikko; Vuori, Tero; Oittinen, Pirkko; Hakkinen, Jukka

    2016-07-01

    In this paper, we present a new video database: CVD2014-Camera Video Database. In contrast to previous video databases, this database uses real cameras rather than introducing distortions via post-processing, which results in a complex distortion space in regard to the video acquisition process. CVD2014 contains a total of 234 videos that are recorded using 78 different cameras. Moreover, this database contains the observer-specific quality evaluation scores rather than only providing mean opinion scores. We have also collected open-ended quality descriptions that are provided by the observers. These descriptions were used to define the quality dimensions for the videos in CVD2014. The dimensions included sharpness, graininess, color balance, darkness, and jerkiness. At the end of this paper, a performance study of image and video quality algorithms for predicting the subjective video quality is reported. For this performance study, we proposed a new performance measure that accounts for observer variance. The performance study revealed that there is room for improvement regarding the video quality assessment algorithms. The CVD2014 video database has been made publicly available for the research community. All video sequences and corresponding subjective ratings can be obtained from the CVD2014 project page (http://www.helsinki.fi/psychology/groups/visualcognition/).

  15. Development of Micro and Nano Crystalline CVD Diamond TL/OSL Radiation Detectors for Clinical Applications

    NASA Astrophysics Data System (ADS)

    Barboza-Flores, Marcelino

    2015-03-01

    Modern radiotherapy methods requires the use of high photon radiation doses delivered in a fraction to small volumes of cancer tumors. An accurate dose assessment for highly energetic small x-ray beams in small areas, as in stereotactic radiotherapy, is necessary to avoid damage to healthy tissue surrounding the tumor. Recent advances on the controlled synthesis of CVD diamond have demonstrated the possibility of using high quality micro and nano crystalline CVD as an efficient detector and dosimeter suitable for high energy photons and energetic particle beams. CVD diamond is a very attractive material for applications in ionizing radiation dosimetry, particularly in the biomedical field since the radiation absorption by a CVD diamond is very close to that of soft tissue. Furthermore, diamond is stable, non-toxic and radiation hard. In the present work we discuss the CVD diamond properties and dosimeter performance and discuss its relevance and advantages of various dosimetry methods, including thermally stimulated luminescence (TL) as well as optically stimulated luminescence (OSL). The recent CVD improved method of growth allows introducing precisely controlled impurities into diamond to provide it with high dosimetry sensitivity. For clinical dosimetry applications, high accuracy of dose measurements, low fading, high sensitivity, good reproducibility and linear dose response characteristics are very important parameters which all are found in CVD diamonds specimens. In some cases, dose linearity and reproducibility in CVD diamond have been found to be higher than standard commercial TLD materials like LiF. In the present work, we discuss the state-of-the art developments in dosimetry applications using CVD diamond. The financial support from Conacyt (Mexico) is greatly acknowledged

  16. Liquid impact and fracture of free-standing CVD diamond

    NASA Astrophysics Data System (ADS)

    Kennedy, Claire F.; Telling, Robert H.; Field, John E.

    1999-07-01

    The Cavendish Laboratory has developed extensive facilities for studies of liquid and solid particle erosion. This paper describes the high-speed liquid impact erosion of thin CVD diamond discs and the variation with grain sizes of the absolute damage threshold velocity (ADTV), viz., the threshold below which the specimen shows no damage. All specimens fail by rear surface cracking and there is shown to be a shallow dependence of rear surface ADTV on grain size. Fracture propagation in CVD diamond has also been monitored using a specially-designed double-torsion apparatus and data for K1C are presented. Tentatively, the results suggest that finer-grained CVD diamond exhibits a higher fracture toughness, although the differences are slight even over a fourfold variation in the mean grain size. No preference for intergranular fracture was observed and one may conclude from this that the grain boundaries themselves do not seriously weaken the material. The large pre-existing flaws, both within and between grains, whose size varies the grain size are believed to be the dominant source of weakness.

  17. CVD Diamond, DLC, and c-BN Coatings for Solid Film Lubrication

    NASA Technical Reports Server (NTRS)

    Miyoshi, Kazuhisa

    1998-01-01

    When the main criteria for judging coating performance were coefficient of friction and wear rate, which had to be less than 0.1 and 10(exp -6) mm(exp 3)/N-m, respectively, carbon- and nitrogen-ion-implanted, fine-grain CVD diamond and DLC ion beam deposited on fine-grain CVD diamond met the requirements regardless of environment (vacuum, nitrogen, and air).

  18. Universal Design: Supporting Students with Color Vision Deficiency (CVD) in Medical Education

    ERIC Educational Resources Information Center

    Meeks, Lisa M.; Jain, Neera R.; Herzer, Kurt R.

    2016-01-01

    Color Vision Deficiency (CVD) is a commonly occurring condition in the general population. For medical students, it has the potential to create unique challenges in the classroom and clinical environments. Few studies have provided medical educators with comprehensive recommendations to assist students with CVD. This article presents a focused…

  19. CVD of SiC and AlN using cyclic organometallic precursors

    NASA Technical Reports Server (NTRS)

    Interrante, L. V.; Larkin, D. J.; Amato, C.

    1992-01-01

    The use of cyclic organometallic molecules as single-source MOCVD precursors is illustrated by means of examples taken from our recent work on AlN and SiC deposition, with particular focus on SiC. Molecules containing (AlN)3 and (SiC)2 rings as the 'core structure' were employed as the source materials for these studies. The organoaluminum amide, (Me2AlNH2)3, was used as the AlN source and has been studied in a molecular beam sampling apparatus in order to determine the gas phase species present in a hot-wall CVD reactor environment. In the case of SiC CVD, a series of disilacyclobutanes (Si(XX')CH2)2 (with X and X' = H, CH3, and CH2SiH2CH3), were examined in a cold-wall, hot-stage CVD reactor in order to compare their relative reactivities and prospective utility as single-source CVD precursors. The parent compound, disilacyclobutane, (SiH2CH2)2, was found to exhibit the lowest deposition temperature (ca. 670 C) and to yield the highest purity SiC films. This precursor gave a highly textured, polycrystalline film on the Si(100) substrates.

  20. A beam radiation monitor based on CVD diamonds for SuperB

    NASA Astrophysics Data System (ADS)

    Cardarelli, R.; Di Ciaccio, A.

    2013-08-01

    Chemical Vapor Deposition (CVD) diamond particle detectors are in use in the CERN experiments at LHC and at particle accelerator laboratories in Europe, USA and Japan mainly as beam monitors. Nowadays it is considered a proven technology with a very fast signal read-out and a very high radiation tolerance suitable for measurements in high radiation environment zones i.e. near the accelerators beam pipes. The specific properties of CVD diamonds make them a prime candidate for measuring single particles as well as high-intensity particle cascades, for timing measurements on the sub-nanosecond scale and for beam protection systems in hostile environments. A single-crystalline CVD (scCVD) diamond sensor, read out with a new generation of fast and high transition frequency SiGe bipolar transistor amplifiers, has been tested for an application as radiation monitor to safeguard the silicon vertex tracker in the SuperB detector from excessive radiation damage, cumulative dose and instantaneous dose rates. Test results with 5.5 MeV alpha particles from a 241Am radioactive source and from electrons from a 90Sr radioactive source are presented in this paper.

  1. Tractable Chemical Models for CVD of Silicon and Carbon

    NASA Technical Reports Server (NTRS)

    Blanquet, E.; Gokoglu, S. A.

    1993-01-01

    Tractable chemical models are validated for the CVD of silicon and carbon. Dilute silane (SiH4) and methane (CH4) in hydrogen are chosen as gaseous precursors. The chemical mechanism for each systems Si and C is deliberately reduced to three reactions in the models: one in the gas phase and two at the surface. The axial-flow CVD reactor utilized in this study has well-characterized flow and thermal fields and provides variable deposition rates in the axial direction. Comparisons between the experimental and calculated deposition rates are made at different pressures and temperatures.

  2. CVD Growth of Carbon Nanotubes: Structure, Catalyst, and Growth

    NASA Technical Reports Server (NTRS)

    Delzeit, Lance

    2003-01-01

    Carbon nanotubes (CNTs) exhibit extraordinary mechanical and unique electronic properties and hence have been receiving much attention in recent years for their potential in nanoelectronics, field emission devices, scanning probes, high strength composites and many more applications. Catalytic decomposition of hydrocarbon feedstock with the aid of supported transition metal catalysts - also known as chemical vapor deposition (CVD) - has become popular to produce single-walled and multi-walled nanotubes (SWNTs, MWNTs) and multiwalled nanofibers (MWNFs). The ability to grow CNTs on patterned substrates and in vertically aligned arrays, and the simplicity of the process, has made CVD growth of CNTs an attractive approach.

  3. CVD diamond pixel detectors for LHC experiments

    NASA Astrophysics Data System (ADS)

    Wedenig, R.; Adam, W.; Bauer, C.; Berdermann, E.; Bergonzo, P.; Bogani, F.; Borchi, E.; Brambilla, A.; Bruzzi, M.; Colledani, C.; Conway, J.; Dabrowski, W.; Delpierre, P.; Deneuville, A.; Dulinski, W.; van Eijk, B.; Fallou, A.; Fizzotti, F.; Foulon, F.; Friedl, M.; Gan, K. K.; Gheeraert, E.; Grigoriev, E.; Hallewell, G.; Hall-Wilton, R.; Han, S.; Hartjes, F.; Hrubec, J.; Husson, D.; Kagan, H.; Kania, D.; Kaplon, J.; Karl, C.; Kass, R.; Knöpfle, K. T.; Krammer, M.; Logiudice, A.; Lu, R.; Manfredi, P. F.; Manfredotti, C.; Marshall, R. D.; Meier, D.; Mishina, M.; Oh, A.; Pan, L. S.; Palmieri, V. G.; Pernicka, M.; Peitz, A.; Pirollo, S.; Polesello, P.; Pretzl, K.; Procario, M.; Re, V.; Riester, J. L.; Roe, S.; Roff, D.; Rudge, A.; Runolfsson, O.; Russ, J.; Schnetzer, S.; Sciortino, S.; Speziali, V.; Stelzer, H.; Stone, R.; Suter, B.; Tapper, R. J.; Tesarek, R.; Trawick, M.; Trischuk, W.; Vittone, E.; Wagner, A.; Walsh, A. M.; Weilhammer, P.; White, C.; Zeuner, W.; Ziock, H.; Zoeller, M.; Blanquart, L.; Breugnion, P.; Charles, E.; Ciocio, A.; Clemens, J. C.; Dao, K.; Einsweiler, K.; Fasching, D.; Fischer, P.; Joshi, A.; Keil, M.; Klasen, V.; Kleinfelder, S.; Laugier, D.; Meuser, S.; Milgrome, O.; Mouthuy, T.; Richardson, J.; Sinervo, P.; Treis, J.; Wermes, N.; RD42 Collaboration

    1999-08-01

    This paper reviews the development of CVD diamond pixel detectors. The preparation of the diamond pixel sensors for bump-bonding to the pixel readout electronics for the LHC and the results from beam tests carried out at CERN are described.

  4. The long term financial impacts of CVD: living standards in retirement.

    PubMed

    Schofield, Deborah; Kelly, Simon; Shrestha, Rupendra; Passey, Megan; Callander, Emily; Percival, Richard

    2012-03-22

    Cardiovascular disease (CVD) has significant economic costs, however these are generally estimated for the present-time and little consideration is given to the long term economic consequences. This study estimates the value of savings those who retire early due to CVD will have accumulated by the time they reach the traditional retirement age of 65 years, and how much lower the value of these savings are compared to those who remained healthy and in the workforce. Using Health&WealthMOD - a microsimulation model of Australians aged 45 to 64 years, regression models were used to analyse the differences between the projected savings and the retirement incomes of people by the time they reach age 65 for those currently working with no chronic condition, and people not in the labour force due to CVD. Over 99% of individuals who are employed full-time will have accumulated some savings at age 65; whereas only 77% of those who are out of the labour force due to CVD will have done so. Those who retire early due to CVD will have a median value of total savings by the time they are 65 of $1833. This is far lower than the expected median value of savings for those who remained in the labour force full-time, who will have $281841 of savings. Not only will early retirement due to cardiovascular disease limit the immediate income and wealth available to individuals, but also reduce their long term financial capacity by reducing their savings. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.

  5. CVD Diamond, DLC, and c-BN Coatings for Solid Film Lubrication

    NASA Technical Reports Server (NTRS)

    Miyoshi, Kazuhisa; Murakawa, Masao; Watanabe, Shuichi; Takeuchi, Sadao; Miyake, Shojiro; Wu, Richard L. C.

    1998-01-01

    The main criteria for judging coating performance were coefficient of friction and wear rate, which had to be less than 0.1 and 10(exp -6) cubic MM /(N*m), respectively. Carbon- and nitrogen-ion-implanted, fine-grain, chemical-vapor-deposited (CVD) diamond and diamondlike carbon (DLC) ion beam deposited on fine-grain CVD diamond met the criteria regardless of environment (vacuum, nitrogen, and air).

  6. Prevalence of undiagnosed cardiovascular risk factors and 10-year CVD risk in male steel industry workers.

    PubMed

    Gray, Benjamin J; Bracken, Richard M; Turner, Daniel; Morgan, Kerry; Mellalieu, Stephen D; Thomas, Michael; Williams, Sally P; Williams, Meurig; Rice, Sam; Stephens, Jeffrey W

    2014-05-01

    To assess the prevalence of undiagnosed cardiovascular disease (CVD) in a cohort of male steelworkers in South Wales, UK. Male steel industry workers (n = 221) with no prior diagnosis of CVD or diabetes accepted a CVD risk assessment within the work environment. Demographic, anthropometric, family, and medical histories were all recorded and capillary blood samples obtained. The 10-year CVD risk was predicted using the QRISK2-2012 algorithm. Up to 81.5% of workers were either overweight or obese. More than 20% of workers were found to have diastolic hypertension, high total cholesterol, and/or a total cholesterol/high-density lipoprotein ratio of six or more. Over one quarter of workers assessed had an increased 10-year CVD risk. Despite a physically demanding occupation, risk assessment in the workplace uncovered significant occult factors in CVD risk in a sample of male heavy industry workers.

  7. COMPARATIVE EVALUATION OF RISK FACTORS FOR CARDIOVASCULAR DISEASE (CVD) IN GENETICALLY PREDISPOSED RATS

    EPA Science Inventory

    Rodent CVD models are increasingly used for understanding individual differences in susceptibility to environmental stressors such as air pollution. We characterized pathologies and a number of known human risk factors of CVD in genetically predisposed, male young adult Spontaneo...

  8. CVD diamond substrate for microelectronics. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Burden, J.; Gat, R.

    1996-11-01

    Chemical Vapor Deposition (CVD) of diamond films has evolved dramatically in recent years, and commercial opportunities for diamond substrates in thermal management applications are promising. The objective of this technology transfer initiative (TTI) is for Applied Science and Technology, Inc. (ASTEX) and AlliedSignal Federal Manufacturing and Technologies (FM&T) to jointly develop and document the manufacturing processes and procedures required for the fabrication of multichip module circuits using CVD diamond substrates, with the major emphasis of the project concentrating on lapping/polishing prior to metallization. ASTEX would provide diamond films for the study, and FM&T would use its experience in lapping, polishing,more » and substrate metallization to perform secondary processing on the parts. The primary goal of the project was to establish manufacturing processes that lower the manufacturing cost sufficiently to enable broad commercialization of the technology.« less

  9. Association of BMI with risk of CVD mortality and all-cause mortality.

    PubMed

    Kee, Chee Cheong; Sumarni, Mohd Ghazali; Lim, Kuang Hock; Selvarajah, Sharmini; Haniff, Jamaiyah; Tee, Guat Hiong Helen; Gurpreet, Kaur; Faudzi, Yusoff Ahmad; Amal, Nasir Mustafa

    2017-05-01

    To determine the relationship between BMI and risk of CVD mortality and all-cause mortality among Malaysian adults. Population-based, retrospective cohort study. Participants were followed up for 5 years from 2006 to 2010. Mortality data were obtained via record linkages with the Malaysian National Registration Department. Multiple Cox regression was applied to compare risk of CVD and all-cause mortality between BMI categories adjusting for age, gender and ethnicity. Models were generated for all participants, all participants the first 2 years of follow-up, healthy participants, healthy never smokers, never smokers, current smokers and former smokers. All fourteen states in Malaysia. Malaysian adults (n 32 839) aged 18 years or above from the third National Health and Morbidity Survey. Total follow-up time was 153 814 person-years with 1035 deaths from all causes and 225 deaths from CVD. Underweight (BMI<18·5 kg/m2) was associated with a significantly increased risk of all-cause mortality, while obesity (BMI ≥30·0 kg/m2) was associated with a heightened risk of CVD mortality. Overweight (BMI=25·0-29·9 kg/m2) was inversely associated with risk of all-cause mortality. Underweight was significantly associated with all-cause mortality in all models except for current smokers. Overweight was inversely associated with all-cause mortality in all participants. Although a positive trend was observed between BMI and CVD mortality in all participants, a significant association was observed only for severe obesity (BMI≥35·0 kg/m2). Underweight was associated with increased risk of all-cause mortality and obesity with increased risk of CVD mortality. Therefore, maintaining a normal BMI through leading an active lifestyle and healthy dietary habits should continue to be promoted.

  10. Coffee consumption is not associated with prevalent subclinical cardiovascular disease (CVD) or the risk of CVD events, in nonalcoholic fatty liver disease: results from the multi-ethnic study of atherosclerosis.

    PubMed

    Simon, Tracey G; Trejo, Maria Esther Perez; Zeb, Irfan; Frazier-Wood, Alexis C; McClelland, Robyn L; Chung, Raymond T; Budoff, Matthew J

    2017-10-01

    Atherosclerosis and its clinical sequelae represent the leading cause of mortality among patients with nonalcoholic fatty liver disease (NAFLD). While epidemiologic data support the hepatoprotective benefits of coffee in NAFLD, whether coffee improves NAFLD-associated CVD risk is unknown. We examined 3710 ethnically-diverse participants from the Multi-Ethnic Study of Atherosclerosis (MESA) cohort, without history of known liver disease, and with available coffee data from a validated 120-item food frequency questionnaire. All participants underwent baseline non-contrast cardiac CT from which NAFLD was defined by liver:spleen ratio (L:S<1.0), and subclinical CVD was defined by coronary artery calcium (CAC)>0. Major CVD events were defined by the first occurrence of myocardial infarction, cardiac arrest, angina, stroke, or CVD death. We used log-binomial regression to calculate the adjusted prevalence ratio (PR) for CAC>0 by coffee intake and NAFLD status, and events were compared between groups using frequency of events within adjusted Cox proportional hazard regression models. Seventeen percent (N=637) of participants met criteria for NAFLD. NAFLD participants were more likely to have elevated BMI (mean 31.1±5.5kg/m 2 vs. 28.0±5.2kg/m 2 , p<0.0001), and diabetes (22% vs. 11%, p<0.0001), but did not differ in daily coffee consumption (p=0.97). Among NAFLD participants, coffee consumption was not associated with prevalent, baseline CAC>0 (PR=1.02 [0.98-1.07]). Over 12.8years of follow-up, 93 NAFLD and 415 non-NAFLD participants experienced a CV event. However, coffee intake was not associated with incident CVD events, in either NAFLD (HR=1.05 [0.91-1.21]) or non-NAFLD participants (HR=1.03 [0.97-1.11]). In a large, population-based cohort, coffee consumption was not associated with the prevalence of subclinical CVD, nor did coffee impact the future risk of major CVD events, regardless of underlying NAFLD status. Copyright © 2017 Elsevier Inc. All rights reserved.

  11. Mapping eQTLs in the Norfolk Island Genetic Isolate Identifies Candidate Genes for CVD Risk Traits

    PubMed Central

    Benton, Miles C.; Lea, Rod A.; Macartney-Coxson, Donia; Carless, Melanie A.; Göring, Harald H.; Bellis, Claire; Hanna, Michelle; Eccles, David; Chambers, Geoffrey K.; Curran, Joanne E.; Harper, Jacquie L.; Blangero, John; Griffiths, Lyn R.

    2013-01-01

    Cardiovascular disease (CVD) affects millions of people worldwide and is influenced by numerous factors, including lifestyle and genetics. Expression quantitative trait loci (eQTLs) influence gene expression and are good candidates for CVD risk. Founder-effect pedigrees can provide additional power to map genes associated with disease risk. Therefore, we identified eQTLs in the genetic isolate of Norfolk Island (NI) and tested for associations between these and CVD risk factors. We measured genome-wide transcript levels of blood lymphocytes in 330 individuals and used pedigree-based heritability analysis to identify heritable transcripts. eQTLs were identified by genome-wide association testing of these transcripts. Testing for association between CVD risk factors (i.e., blood lipids, blood pressure, and body fat indices) and eQTLs revealed 1,712 heritable transcripts (p < 0.05) with heritability values ranging from 0.18 to 0.84. From these, we identified 200 cis-acting and 70 trans-acting eQTLs (p < 1.84 × 10−7) An eQTL-centric analysis of CVD risk traits revealed multiple associations, including 12 previously associated with CVD-related traits. Trait versus eQTL regression modeling identified four CVD risk candidates (NAAA, PAPSS1, NME1, and PRDX1), all of which have known biological roles in disease. In addition, we implicated several genes previously associated with CVD risk traits, including MTHFR and FN3KRP. We have successfully identified a panel of eQTLs in the NI pedigree and used this to implicate several genes in CVD risk. Future studies are required for further assessing the functional importance of these eQTLs and whether the findings here also relate to outbred populations. PMID:24314549

  12. Effect of age, gender, ethnicity, socioeconomic status and region on dispensing of CVD secondary prevention medication in New Zealand: the Atlas of Health Care Variation CVD cohort (VIEW-1).

    PubMed

    Kerr, Andrew; Exeter, Dan; Hanham, Grant; Grey, Corina; Zhao, Jinfeng; Riddell, Tania; Lee, Mildred; Jackson, Rod; Wells, Sue

    2014-08-15

    Triple therapy with anti-platelet/anti-coagulant, blood pressure (BP)-lowering, and statin medications improves outcomes in atherosclerotic cardiovascular disease (CVD). However, in practice there is often a substantial evidence-practice gap, with sub-optimal initiation and longer-term adherence. Our aim was to enumerate a contemporary national cohort of people with significant CVD and report the variation in CVD secondary prevention dispensing by demographic variables. Using anonymised linkage of national data sets, we identified 86,256 individuals, alive and residing in New Zealand at the end of 2010, aged 30-79 years who were hospitalised for an atherosclerotic CVD event or procedure in the previous10 years. This cohort was linked to the national pharmaceutical dispensing dataset to assess dispensing of CVD prevention medications during the 2011 calendar year. Adequate dispensing was defined as being dispensed a drug in at least 3 of the 4 quarters of the year. Multivariate regression was used to identify independent predictors of adequate dispensing. 59% were maintained on triple therapy, 77% on BP-lowering medication, 75% on anti-platelet/anti-coagulants and 70% on statins. From multivariate analysis, patients less than 50 years were about 20% less likely than older patients and women were 10% less likely than men to be maintained on triple therapy. Indian patients were about 10% more likely to be maintained on triple therapy than NZ European/Others. Those living in the Southern Cardiac Network region of New Zealand had slightly higher rates of triple therapy than National Cardiac Regions further north. The significant under-utilisation of safe and inexpensive secondary prevention medication, particularly in younger people and women, provides an opportunity to improve CVD outcomes in this easily identifiable high-risk population.

  13. Superhydrophobic Copper Surfaces with Anticorrosion Properties Fabricated by Solventless CVD Methods.

    PubMed

    Vilaró, Ignasi; Yagüe, Jose L; Borrós, Salvador

    2017-01-11

    Due to continuous miniaturization and increasing number of electrical components in electronics, copper interconnections have become critical for the design of 3D integrated circuits. However, corrosion attack on the copper metal can affect the electronic performance of the material. Superhydrophobic coatings are a commonly used strategy to prevent this undesired effect. In this work, a solventless two-steps process was developed to fabricate superhydrophobic copper surfaces using chemical vapor deposition (CVD) methods. The superhydrophobic state was achieved through the design of a hierarchical structure, combining micro-/nanoscale domains. In the first step, O 2 - and Ar-plasma etchings were performed on the copper substrate to generate microroughness. Afterward, a conformal copolymer, 1H,1H,2H,2H-perfluorodecyl acrylate-ethylene glycol diacrylate [p(PFDA-co-EGDA)], was deposited on top of the metal via initiated CVD (iCVD) to lower the surface energy of the surface. The copolymer topography exhibited a very characteristic and unique nanoworm-like structure. The combination of the nanofeatures of the polymer with the microroughness of the copper led to achievement of the superhydrophobic state. AFM, SEM, and XPS were used to characterize the evolution in topography and chemical composition during the CVD processes. The modified copper showed water contact angles as high as 163° and hysteresis as low as 1°. The coating withstood exposure to aggressive media for extended periods of time. Tafel analysis was used to compare the corrosion rates between bare and modified copper. Results indicated that iCVD-coated copper corrodes 3 orders of magnitude slower than untreated copper. The surface modification process yielded repeatable and robust superhydrophobic coatings with remarkable anticorrosion properties.

  14. Correlation of CVD Diamond Electron Emission with Film Properties

    NASA Astrophysics Data System (ADS)

    Bozeman, S. P.; Baumann, P. K.; Ward, B. L.; Nemanich, R. J.; Dreifus, D. L.

    1996-03-01

    Electron field emission from metals is affected by surface morphology and the properties of any dielectric coating. Recent results have demonstrated low field electron emission from p-type diamond, and photoemission measurements have identified surface treatments that result in a negative electron affinity (NEA). In this study, the field emission from diamond is correlated with surface treatment, surface roughness, and film properties (doping and defects). Electron emission measurements are reported on diamond films synthesized by plasma CVD. Ultraviolet photoemission spectroscopy indicates that the CVD films exhibit a NEA after exposure to hydrogen plasma. Field emission current-voltage measurements indicate "threshold voltages" ranging from approximately 20 to 100 V/micron.

  15. Movers and stayers: The geography of residential mobility and CVD hospitalisations in Auckland, New Zealand.

    PubMed

    Exeter, Daniel J; Sabel, Clive E; Hanham, Grant; Lee, Arier C; Wells, Susan

    2015-05-01

    The association between area-level disadvantage and health and social outcomes is unequivocal. However, less is known about the health impact of residential mobility, particularly at intra-urban scales. We used an encrypted National Health Index (eNHI) number to link individual-level data recorded in routine national health databases to construct a cohort of 641,532 participants aged 30+ years to investigate the association between moving and CVD hospitalisations in Auckland, New Zealand. Residential mobility was measured for participants according to changes in the census Meshblock of usual residence, obtained from the Primary Health Organisation (PHO) database for every calendar quarter between 1/1/2006 and 31/12/2012. The NZDep2006 area deprivation score at the start and end of a participant's inclusion in the study was used to measure deprivation mobility. We investigated the relative risk of movers being hospitalised for CVD relative to stayers using multi-variable binomial regression models, controlling for age, gender, deprivation and ethnicity. Considered together, movers were 1.22 (1.19-1.26) times more likely than stayers to be hospitalised for CVD. Using the 5×5 deprivation origin-destination matrix to model a patient's risk of CVD based on upward, downward or sideways deprivation mobility, movers within the least deprived (NZDep2006 Quintile 1) areas were 10% less likely than stayers to be hospitalised for CVD, while movers within the most deprived (NZDep2006 Q5) areas were 45% more likely than stayers to have had their first CVD hospitalisation in 2006-2012 (RR: 1.45 [1.35-1.55]). Participants who moved upward also had higher relative risks of having a CVD event, although their risk was less than those observed for participants experiencing downward deprivation mobility. This research suggests that residential mobility is an important determinant of CVD in Auckland. Further investigation is required to determine the impact moving has on the risk of

  16. Predictors of CVD among breast cancer survivors in an integrated health system | Division of Cancer Prevention

    Cancer.gov

    PROJECT SUMMARY / ABSTRACT Breast cancer survivors are at high risk of developing and dying from cardiovascular disease (CVD) following breast cancer diagnosis, but subpopulations at increased risk and targets for intervention have not been well- characterized. A growing body of literature links CVD with specific cardiotoxic cancer treatments. CVD risk among breast cancer

  17. Performance of irradiated CVD diamond micro-strip sensors

    NASA Astrophysics Data System (ADS)

    Adam, W.; Berdermann, E.; Bergonzo, P.; Bertuccio, G.; Bogani, F.; Borchi, E.; Brambilla, A.; Bruzzi, M.; Colledani, C.; Conway, J.; D'Angelo, P.; Dabrowski, W.; Delpierre, P.; Deneuville, A.; Dulinski, W.; van Eijk, B.; Fallou, A.; Fizzotti, F.; Foulon, F.; Friedl, M.; Gan, K. K.; Gheeraert, E.; Hallewell, G.; Han, S.; Hartjes, F.; Hrubec, J.; Husson, D.; Kagan, H.; Kania, D.; Kaplon, J.; Kass, R.; Koeth, T.; Krammer, M.; Logiudice, A.; Lu, R.; mac Lynne, L.; Manfredotti, C.; Meier, D.; Mishina, M.; Moroni, L.; Noomen, J.; Oh, A.; Pan, L. S.; Pernicka, M.; Peitz, A.; Perera, L.; Pirollo, S.; Procario, M.; Riester, J. L.; Roe, S.; Rousseau, L.; Rudge, A.; Russ, J.; Sala, S.; Sampietro, M.; Schnetzer, S.; Sciortino, S.; Stelzer, H.; Stone, R.; Suter, B.; Tapper, R. J.; Tesarek, R.; Trischuk, W.; Tromson, D.; Vittone, E.; Walsh, A. M.; Wedenig, R.; Weilhammer, P.; Wetstein, M.; White, C.; Zeuner, W.; Zoeller, M.; Plano, R.; Somalwar, S. V.; Thomson, G. B.

    2002-01-01

    CVD diamond detectors are of interest for charged particle detection and tracking due to their high radiation tolerance. In this article, we present, for the first time, beam test results from recently manufactured CVD diamond strip detectors and their behavior under low doses of electrons from a β-source and the performance before and after intense (>10 15/cm 2) proton- and pion-irradiations. We find that low dose irradiation increase the signal-to-noise ratio (pumping of the signal) and slightly deteriorate the spatial resolution. Intense irradiation with protons 2.2×10 15 p/ cm2 lowers the signal-to-noise ratio slightly. Intense irradiation with pions 2.9×10 15 π/ cm2 lowers the signal-to-noise ratio more. The spatial resolution of the diamond sensors improves after irradiations.

  18. THE RELATIONSHIP BETWEEN OZONE-INDUCED LUNG INJURY, ANTIOXIDANT COMPENSATION AND UNDERLYING CARDIOVASCULAR DISEASE (CVD).

    EPA Science Inventory

    Increased levels of oxidants and compromised compensatory response are associated with CVD susceptibility. We hypothesized that rat strains demonstrating genetic CVD will have lower levels of antioxidants and greater ozone-induced pulmonary injury relative to healthy strains. Mal...

  19. Graphene Synthesis by Plasma-Enhanced CVD Growth with Ethanol

    DOE PAGES

    Campo, Teresa; Cotto, María; Márquez, Francisco; ...

    2016-03-01

    A modified route to synthesize graphene flakes is proposed using the Chemical Vapor Deposition (CVD) technique, by using copper substrates as supports. The carbon source used was ethanol, the synthesis temperature was 950°C and the pressure was controlled along the whole process. In this CVD synthesis process the incorporation of the carbon source was produced at low pressure and 950°C inducing the appearance of a plasma blue flash inside the quartz tube. Apparently, the presence of this plasma blue flash is required for obtaining graphene flakes. The synthesized graphene was characterized by different techniques, showing the presence of non-oxidized graphenemore » with high purity.« less

  20. Labour force participation and the influence of having CVD on income poverty of older workers.

    PubMed

    Schofield, Deborah J; Callander, Emily J; Shrestha, Rupendra N; Percival, Richard; Kelly, Simon J; Passey, Megan E

    2012-04-05

    In addition to being the leading cause of death, cardiovascular disease (CVD) also impacts upon the ability of individuals to function normally in everyday activities, which is likely to affect individuals' employment. This paper will quantify the relationship between labour force participation, CVD and being in poverty. The 2003 Survey of Disability, Ageing and Carers (SDAC) data were used to assess the impact of having CVD on being in poverty amongst the older working aged (aged 45 to 64) population in Australia. Those not in the labour force with no chronic health condition are 93% less likely to be in poverty than those not in the labour force due to CVD (OR 0.07, 95%CI: 0.07-0.07, p<.0001). The likelihood of being in poverty varies with labour force status for those with CVD: those who were either in full time (OR 0.04, 95% CI: 0.04-0.05, p<.0001) or part time (OR 0.19, 95% CI: 0.18-0.19) employment are significantly less likely to be in poverty than those who have had to retire because of the condition. The efforts to increase the labour force participation of individuals with CVD, or ideally prevent the onset of the condition will likely improve their living standards. This study has shown that having CVD and not being in the labour force because of the condition drastically increases the chances of living in poverty. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  1. Salivary Biomarkers of Chronic Psychosocial Stress and CVD Risks: A Systematic Review.

    PubMed

    An, Kyungeh; Salyer, Jeanne; Brown, Roy E; Kao, Hsueh-Fen Sabrina; Starkweather, Angela; Shim, Insop

    2016-05-01

    The use of salivary biomarkers in stress research is increasing, and the precision and accuracy with which researchers are able to measure these biomarkers have dramatically improved. Chronic psychosocial stress is often linked to the pathogenesis of cardiovascular disease (CVD). Salivary biomarkers represent a noninvasive biological method of characterizing the stress phenomenon that may help to more fully describe the mechanism by which stress contributes to the pathogenesis and outcomes of CVD. We conducted a systematic review of 40 research articles to identify the salivary biomarkers researchers have most commonly used to help describe the biological impact of chronic psychosocial stress and explore its associations with CVD risk. We address strengths and weaknesses of specimen collection and measurement. We used PubMed, CINAHL, EBSCOhost, Web of Science, BIOSIS Previews, Biological Sciences (ProQuest), and Dissertations/Theses (ProQuest) to retrieve 387 initial articles. Once we applied our inclusion/exclusion criteria to specifically target adult human studies dealing with chronic stress rather than acute/laboratory-induced stress, 40 studies remained, which we synthesized using Preferred Reporting Items for Systematic Reviews and Meta-Analyses criteria. Cortisol was the biomarker used most frequently. Sources of psychosocial stress included job strain, low socioeconomic status, and environmental factors. Overall, psychosocial stress was associated with CVD risks such as vascular pathology (hypertension, blood pressure fluctuation, and carotid artery plaque) as well as metabolic factors such as abnormal blood glucose, dyslipidemia, and elevated cardiac enzymes. Diverse salivary biomarkers have been useful in stress research, particularly when linked to CVD risks. © The Author(s) 2015.

  2. Enhanced cold wall CVD reactor growth of horizontally aligned single-walled carbon nanotubes

    NASA Astrophysics Data System (ADS)

    Mu, Wei; Kwak, Eun-Hye; Chen, Bingan; Huang, Shirong; Edwards, Michael; Fu, Yifeng; Jeppson, Kjell; Teo, Kenneth; Jeong, Goo-Hwan; Liu, Johan

    2016-05-01

    HASynthesis of horizontally-aligned single-walled carbon nanotubes (HA-SWCNTs) by chemical vapor deposition (CVD) directly on quartz seems very promising for the fabrication of future nanoelectronic devices. In comparison to hot-wall CVD, synthesis of HA-SWCNTs in a cold-wall CVD chamber not only means shorter heating, cooling and growth periods, but also prevents contamination of the chamber. However, since most synthesis of HA-SWCNTs is performed in hot-wall reactors, adapting this well-established process to a cold-wall chamber becomes extremely crucial. Here, in order to transfer the CVD growth technology from a hot-wall to a cold-wall chamber, a systematic investigation has been conducted to determine the influence of process parameters on the HA-SWCNT's growth. For two reasons, the cold-wall CVD chamber was upgraded with a top heater to complement the bottom substrate heater; the first reason to maintain a more uniform temperature profile during HA-SWCNTs growth, and the second reason to preheat the precursor gas flow before projecting it onto the catalyst. Our results show that the addition of a top heater had a significant effect on the synthesis. Characterization of the CNTs shows that the average density of HA-SWCNTs is around 1 - 2 tubes/ μm with high growth quality as shown by Raman analysis. [Figure not available: see fulltext.

  3. Injection doping of ultrathin microcrystalline silicon films prepared by CC-CVD

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Koynov, S.; Grebner, S.; Schwarz, R.

    1997-07-01

    Recently, the authors have proposed a cyclic method, referred to as Closed Chamber CVD (CC-CVD), for the preparation of {micro}c-Si films of high crystalline fraction at increased deposition rates. In this work, they first report new process conditions of CC-CVD, which result in growth of highly crystalline films with a sharp interface on a foreign substrate. Then these conditions are further used together with a pulsed injection of B{sub 2}H{sub 6} in an appropriate moment of each cycle, so that the disturbance of the crystallization process is prevented. A series of ultrathin {micro}c-Si films, doped by this technique, is characterizedmore » by conductivity measurements, SEM, Raman Scattering, optical transmission and UV reflection. A strong reduction of the transient interface layer is achieved and conductivity as high as 2 S/cm with an activation energy of 27 meV is reached.« less

  4. Highly Crystalline CVD-grown Multilayer MoSe2 Thin Film Transistor for Fast Photodetector

    PubMed Central

    Jung, Chulseung; Kim, Seung Min; Moon, Hyunseong; Han, Gyuchull; Kwon, Junyeon; Hong, Young Ki; Omkaram, Inturu; Yoon, Youngki; Kim, Sunkook; Park, Jozeph

    2015-01-01

    Hexagonal molybdenum diselenide (MoSe2) multilayers were grown by chemical vapor deposition (CVD). A relatively high pressure (>760 Torr) was used during the CVD growth to achieve multilayers by creating multiple nuclei based on the two-dimensional crystal growth model. Our CVD-grown multilayer MoSe2 thin-film transistors (TFTs) show p-type-dominant ambipolar behaviors, which are attributed to the formation of Se vacancies generated at the decomposition temperature (650 °C) after the CVD growth for 10 min. Our MoSe2 TFT with a reasonably high field-effect mobility (10 cm2/V · s) exhibits a high photoresponsivity (93.7 A/W) and a fast photoresponse time (τrise ~ 0.4 s) under the illumination of light, which demonstrates the practical feasibility of multilayer MoSe2 TFTs for photodetector applications. PMID:26477744

  5. Are your patients with risk of CVD getting the viscous soluble fiber they need?

    PubMed

    Shamliyan, Tatyana A; Jacobs, David R; Raatz, Susan K; Nordstrom, David L; Keenan, Joseph M

    2006-09-01

    A diet that includes 5 to 10 g/d of viscous soluble fiber reduces cardiovascular disease (CVD) events and death independent of baseline risk. Consuming foods rich in viscous soluble fiber reduces low-density lipoprotein cholesterol (LDL-C) blood levels 10% to 15% with expected reduction in CVD events by 10% to 15%. Routinely counsel adults at risk of CVD to promote a healthy diet: assess dietary fiber consumption; recommend specific foods rich in viscous soluble fiber; monitor LDL-C levels and encourage increased dietary fiber intake at follow-up visits; motivate patients to comply with recommendations.

  6. Scattering of low-energetic atoms and molecules from a boron-doped CVD diamond surface

    NASA Astrophysics Data System (ADS)

    Allenbach, M.; Neuland, M. B.; Riedo, A.; Wurz, P.

    2018-01-01

    For the detection of low energetic neutral atoms for the remote sensing of space plasmas, charge state conversion surfaces are used to ionize the neutrals for their subsequent measurement. We investigated a boron-doped Chemical Vapor Deposition (CVD) diamond sample for its suitability to serve as a conversion surface on future space missions, such as NASA's Interstellar Mapping and Acceleration Probe. For H and O atoms incident on conversion surface with energies ranging from 195 to 1000 eV and impact angles from 6° to 15° we measured the angular scattering distributions and the ionization yields. Atomic force microscope and laser ablation ionization mass spectrometry analyses were applied to further characterize the sample. Based on a figure-of-merit, which included the ionization yield and angular scatter distribution, the B-doped CVD surface was compared to other, previously characterized conversion surfaces, including e.g. an undoped CVD diamond with a metallized backside. For particle energies below 390 eV the performance of the B-doped CVD conversion surfaces is comparable to surfaces studied before. For higher energies the figure-of-merit indicates a superior performance. From our studies we conclude that the B-doped CVD diamond sample is well suited for its application on future space missions.

  7. CVD growth of graphene at low temperature

    NASA Astrophysics Data System (ADS)

    Zeng, Changgan

    2012-02-01

    Graphene has attracted a lot of research interest owing to its exotic properties and a wide spectrum of potential applications. Chemical vapor deposition (CVD) from gaseous hydrocarbon sources has shown great promises for large-scale graphene growth. However, high growth temperature, typically 1000^oC, is required for such growth. In this talk, I will show a revised CVD route to grow graphene on Cu foils at low temperature, adopting solid and liquid hydrocarbon feedstocks. For solid PMMA and polystyrene precursors, centimeter-scale monolayer graphene films are synthesized at a growth temperature down to 400^oC. When benzene is used as the hydrocarbon source, monolayer graphene flakes with excellent quality are achieved at a growth temperature as low as 300^oC. I will also talk about our recent progress on low-temperature graphene growth using paraterphenyl as precursor. The successful low-temperature growth can be qualitatively understood from the first principles calculations. Our work might pave a way to economical and convenient growth route of graphene, as well as better control of the growth pattern of graphene at low temperature.

  8. Radiation tolerance of CVD diamond detectors for pions and protons

    NASA Astrophysics Data System (ADS)

    Adam, W.; Berdermann, E.; Bergonzo, P.; Bertuccio, G.; Bogani, F.; Borchi, E.; Brambilla, A.; Bruzzi, M.; Colledani, C.; Conway, J.; D'Angelo, P.; Dabrowski, W.; Delpierre, P.; Deneuville, A.; Dulinski, W.; van Eijk, B.; Fallou, A.; Fizzotti, F.; Foulon, F.; Friedl, M.; Gan, K. K.; Gheeraert, E.; Hallewell, G.; Han, S.; Hartjes, F.; Hrubec, J.; Husson, D.; Kagan, H.; Kania, D.; Kaplon, J.; Kass, R.; Koeth, T.; Krammer, M.; Logiudice, A.; Lu, R.; mac Lynne, L.; Manfredotti, C.; Meier, D.; Mishina, M.; Moroni, L.; Noomen, J.; Oh, A.; Pan, L. S.; Pernicka, M.; Peitz, A.; Perera, L.; Pirollo, S.; Procario, M.; Riester, J. L.; Roe, S.; Rousseau, L.; Rudge, A.; Russ, J.; Sala, S.; Sampietro, M.; Schnetzer, S.; Sciortino, S.; Stelzer, H.; Stone, R.; Suter, B.; Tapper, R. J.; Tesarek, R.; Trischuk, W.; Tromson, D.; Vittone, E.; Walsh, A. M.; Wedenig, R.; Weilhammer, P.; Wetstein, M.; White, C.; Zeuner, W.; Zoeller, M.

    2002-01-01

    The paper gives new results on the radiation tolerance of CVD diamond for irradiation with 300 MeV/ c pions and 24 GeV/ c protons. The measured charge signal spectrum is compared at several irradiation levels with the spectrum calculated by a model. Irradiation by particles causes damage leading to a decrease of the charge signal. However, both the measurements and the outcome from the model show that for tracker applications this drawback is at least partly counterbalanced by a narrowing of the distribution curve of the charge signal. As a result, the efficiency of a CVD diamond tracker is less affected by irradiation than the mean charge signal.

  9. How dietary evidence for the prevention and treatment of CVD is translated into practice in those with or at high risk of CVD: a systematic review.

    PubMed

    Schumacher, Tracy L; Burrows, Tracy L; Neubeck, Lis; Redfern, Julie; Callister, Robin; Collins, Clare E

    2017-01-01

    CVD is a leading cause of mortality and morbidity, and nutrition is an important lifestyle factor. The aim of the present systematic review was to synthesise the literature relating to knowledge translation (KT) of dietary evidence for the prevention and treatment of CVD into practice in populations with or at high risk of CVD. A systematic search of six electronic databases (CINAHL, Cochrane, EMBASE, MEDLINE, PsycINFO and Scopus) was performed. Studies were included if a nutrition or dietary KT was demonstrated to occur with a relevant separate measureable outcome. Quality was assessed using a tool adapted from two quality checklists. Population with or at high risk of CVD or clinicians likely to treat this population. A total of 4420 titles and abstracts were screened for inclusion, with 354 full texts retrieved to assess inclusion. Forty-three articles were included in the review, relating to thirty-five separate studies. No studies specifically stated their aim to be KT. Thirty-one studies were in patient or high-risk populations and four targeted health professionals. Few studies stated a theory on which the intervention was based (n 10) and provision of instruction was the most common behaviour change strategy used (n 26). KT in nutrition and dietary studies has been inferred, not stated, with few details provided regarding how dietary knowledge is translated to the end user. This presents challenges for implementation by clinicians and policy and decision makers. Consequently a need exists to improve the quality of publications in this area.

  10. Tribological Characteristics and Applications of Superhard Coatings: CVD Diamond, DLC, and c-BN

    NASA Technical Reports Server (NTRS)

    Miyoshi, Kazuhisa; Murakawa, Masao; Watanabe, Shuichi; Takeuchi, Sadao; Wu, Richard L. C.

    1999-01-01

    Results of fundamental research on the tribological properties of chemical-vapor-deposited (CVD) diamond, diamondlike carbon, and cubic boron nitride films in sliding contact with CVD diamond in ultrahigh vacuum, dry nitrogen, humid air, and water are discussed. Furthermore, the actual and potential applications of the three different superhard coatings in the field of tribology technology, particularly for wear parts and tools, are reviewed.

  11. Nutrient Intake, Physical Activity, and CVD Risk Factors in Children

    PubMed Central

    Day, R. Sue; Fulton, Janet E.; Dai, Shifan; Mihalopoulos, Nicole L.; Barradas, Danielle T.

    2009-01-01

    Background Associations among dietary intake, physical activity, and cardiovascular disease (CVD) risk factors are inconsistent among male and female youth, possibly from lack of adjustment for pubertal status. The purpose of this report is to describe the associations of CVD risk factors among youth, adjusted for sexual maturation. Methods Data analyzed in 2007 from a sumsample of 556 children aged 8, 11, and 14 years in Project HeartBeat!, 1991–1993, provide cross-sectional patterns of CVD risk factors by age and gender, adjusting for sexual maturation, within dietary fat and physical activity categories. Results Girls consuming moderate- to high-fat diets were significantly less physically active than those consuming low-fat diets. Boys and girls consuming high-fat diets had higher saturated fat and cholesterol intakes than children in low-fat categories. Boys had no significant differences in physical activity, blood pressure, waist circumference, or plasma cholesterol levels across fat categories. Girls’ plasma cholesterol levels showed no significant differences across fat categories. Dietary intake did not differ across moderate-to-vigorous physical activity (MVPA) categories within gender. There were no differences in BMI by fat or MVPA categories for either gender. Girls’ waist circumference differed significantly by fat category, and systolic blood pressure differed significantly across fat and MVPA categories. Boys’ fifth-phase diastolic blood pressure was significantly different across MVPA categories. Conclusions Girls consuming atherogenic diets were significantly less physically active than those with low fat intakes, whereas boys consuming high-fat diets did not show differences in physical activity measures. With the prevalence of overweight rising among youth, the impact of atherogenic diets and sedentary lifestyles on CVD risk factors is of concern to public health professionals. PMID:19524152

  12. PaxVax CVD 103-HgR single-dose live oral cholera vaccine.

    PubMed

    Levine, Myron M; Chen, Wilbur H; Kaper, James B; Lock, Michael; Danzig, Lisa; Gurwith, Marc

    2017-03-01

    Cholera remains a problem in developing countries and a risk for travelers. Hypochlorhydria, blood group O, cardiac and renal disease increase the risk of developing cholera gravis. Oral vaccines containing inactivated Vibrio cholerae and requiring two doses are available in some countries. No cholera vaccine had been available for U.S. travelers for decades until 2016 when CVD 103-HgR (VAXCHORA™), an oral live attenuated vaccine, was licensed by the U.S. FDA. Areas covered: Enduring protection following wild-type cholera provided the rationale to develop a single-dose live oral vaccine. CVD 103-HgR is well-tolerated and protects against cholera caused by V. cholerae O1 of either serotype (Inaba, Ogawa) and biotype (El Tor, Classical). Since 90% vaccine efficacy is evident 10 days post-ingestion of a single dose, CVD 103-HgR can rapidly protect travelers. Vibriocidal antibody seroconversion correlates with protection; >90% of U.S. adult (including elderly) vaccinees seroconvert. The U.S. Public Health Service's Advisory Committee on Immunization Practices recommends CVD 103-HgR for U.S. travelers to areas of ongoing cholera transmission. Expert commentary: Next steps include evaluations in children, post-licensure safety and effectiveness monitoring, diminishing cold chain constraints, optimizing a 'high-dose' formulation for developing countries, and diminishing/eliminating the need for water to administer a dose.

  13. Variability in Chemical Vapor Deposited Zinc Sulfide: Assessment of Legacy and International CVD ZnS Materials

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McCloy, John S.; Korenstein, Ralph

    2009-10-06

    Samples of CVD ZnS from the United States, Germany, Israel, and China were evaluated using transmission spectroscopy, x-ray diffraction, photoluminescence, and biaxial flexure testing. Visible and near-infrared scattering, 6 μm absorption, and ultraviolet cut-on edge varied substantially in tested materials. Crystallographic hexagonality and texture was determined and correlated with optical scattering. Transmission cut-on (ultraviolet edge) blue-shifts with annealing and corresponds to visible color but not the 6 μm absorption. Photoluminescence results suggest that CVD ZnS exhibits a complex suite of electronic bandgap defects. All CVD ZnS tested with biaxial flexure exhibit similar fracture strength values and Weibull moduli. This surveymore » suggests that technical understanding of the structure and optical properties CVD ZnS is still in its infancy.« less

  14. CVD-predictive performances of "a body shape index" versus simple anthropometric measures: Tehran lipid and glucose study.

    PubMed

    Bozorgmanesh, Mohammadreza; Sardarinia, Mahsa; Hajsheikholeslami, Farhad; Azizi, Fereidoun; Hadaegh, Farzad

    2016-02-01

    To examine whether a body shape index (ABSI) calculated by using waist circumference (WC) adjusted for height and weight could improve the predictive performances for cardiovascular disease (CVD) of the Framingham's general CVD algorithm and to compare its predictive performances with other anthropometric measures. We analyzed data on a 10-year population-based follow-up of 8,248 (4,471 women) individuals aged ≥30 years, free of CVD at baseline. CVD risk was estimated for a 1 SD increment in ABSI, body mass index (BMI), waist-to-hip ratio (WHpR) and waist-to-height ratio (WHtR), by incorporating them, one at a time, into multivariate accelerated failure time models. ABSI was associated with multivariate-adjusted increased risk of incident CVD among both men (1.26, 95% CI 1.09-1.46) and women (1.17, 1.03-1.32). Among men, for a one-SD increment, ABSI conferred a greater increase in the hazard of CVD [1.26 (1.09-1.46)] than did BMI [1.06 (0.94-1.20)], WC [1.15(1.03-1.28)], WHpR [1.02 (1.01-1.03)] and WHtR [1.16 (1.02-1.31)], and the corresponding figures among women were 1.17 (1.03-1.32), 1.02 (0.90-1.16), 1.11 (0.98-1.27), 1.03 (1.01-1.05) and 1.14 (0.99-1.03), respectively. ABSI as well as other anthropometric measures failed to add to the predictive ability of the Framingham general CVD algorithm either. Although ABSI could not improve the predictability of the Framingham algorithm, it provides more information than other traditional anthropometric measures in settings where information on traditional CVD risk factors are not available, and it can be used as a practical criterion to predict adiposity-related health risks in clinical assessments.

  15. Economic efficiency of primary care for CVD prevention and treatment in Eastern European countries

    PubMed Central

    2013-01-01

    Background Cardiovascular disease (CVD) is the main cause of morbidity and mortality worldwide, but it also is highly preventable. The prevention rate mainly depends on the patients’ readiness to follow recommendations and the state’s capacity to support patients. Our study aims to show that proper primary care can decrease the CVD-related morbidity rate and increase the economic efficiency of the healthcare system. Since their admission to the European Union (EU), the Eastern European countries have been in a quest to achieve the Western European standards of living. As a representative Eastern European country, Romania implemented the same strategies as the rest of Eastern Europe, reflected in the health status and lifestyle of its inhabitants. Thus, a valid health policy implemented in Romania should be valid for the rest of the Eastern European countries. Methods Based on the data collected during the EUROASPIRE III Romania Follow Up study, the potential costs of healthcare were estimated for various cases over a 10-year time period. The total costs were split into patient-supported costs and state-supported costs. The state-supported costs were used to deduce the rate of patients with severe CVD that can be treated yearly. A statistical model for the evolution of this rate was computed based on the readiness of the patients to comply with proper primary care treatment. Results We demonstrate that for patients ignoring the risks, a severe CVD has disadvantageous economic consequences, leading to increased healthcare expenses and even poverty. In contrast, performing appropriate prevention activities result in a decrease of the expenses allocated to a (eventual) CVD. In the long-term, the number of patients with severe CVD that can be treated increases as the number of patients receiving proper primary care increases. Conclusions Proper primary care can not only decrease the risk of major CVD but also decrease the healthcare costs and increase the number of

  16. Photo-oxidation of Polymers Synthesized by Plasma and Initiated CVD

    DOE PAGES

    Baxamusa, Salmaan H.; Suresh, Aravind; Ehrmann, Paul; ...

    2015-11-09

    Plasma polymers are often limited by their susceptibility to spontaneous and photo-oxidation. We show that the unusual photoluminescence (PL) behavior of a plasma polymer of trans-2-butene is correlated with its photoluminescence strength. These photo-processes occur under blue light illumination (λ=405 nm), distinguishing them from traditional ultraviolet degradation of polymers. These photo-active defects are likely formed during the plasma deposition process and we show that a polymer synthesized using initiated (i)CVD, non-plasma method, has 1000× lower PL signal and enhanced photo-stability. In conclusion, non-plasma methods such as iCVD may therefore be a route to overcoming material aging issues that limit themore » adoption of plasma polymers.« less

  17. Reproducibility of CVD diamond detectors for radiotherapy dosimetry

    NASA Astrophysics Data System (ADS)

    Betzel, G. T.; Lansley, S. P.; McKay, D.; Meyer, J.

    2012-11-01

    Three in-house X-ray detectors based on diamond chemical vapor deposition (CVD) from the same manufactured batch of single crystal films were investigated for their reproducibility. Leakage current, priming dose, response dynamics, dose linearity, dependence on dose rate and angular dependence were used to evaluate differences between detectors. Slight differences were seen in leakage currents before (<1.5 pA) and after (<12 pA) irradiation. A priming dose of ˜7 Gy and rise and fall times of 2 s were found for all three detectors. Sensitivities differed by up to 10%. Dependence on dose rate were similar (∆=0.92-0.94). Angular dependence was minimal (97-102% avg.). Differences in detector performance appeared to be primarily due to film thickness, which can significantly change sensitivities (nC Gy-1) and applied fields (V μm-1) for detectors with small sensitive volumes. Results suggest that preselection of CVD diamond films according to thickness in addition to material quality would be required to avoid individual calibration, which is performed for commercially available natural diamond detectors.

  18. Correlates of CVD and discussing sexual issues with physicians among male military veterans.

    PubMed

    Smith, Matthew Lee; Goltz, Heather Honoré; Motlagh, Audry S; Ahn, SangNam; Bergeron, Caroline D; Ory, Marcia G

    2016-10-01

    This study aims to identify socio-demographic and health behavior factors associated with cardiovascular disease (CVD) diagnosis and patient-physician communication concerning sexual issues among older Veterans. Cross-sectional data were collected from 635 male Veterans over age 55 years as part of the 2010 National Social Life, Health and Aging Project, a nationally-representative, population-based study of community-dwelling older Americans. Two independent logistic regression analyses were performed. Over 33% of Veterans were aged 75 years or older. Over one-half of participants reported having a CVD diagnosis (58%) and sexual intercourse within the previous year (58%); over one-third (37%) reported having one or more sexual dysfunctions and discussing sexual issues with their physician (42%). Veterans diagnosed with CVD were significantly more likely to self-identify as racial/ethnic minorities (OR=1.89, P=0.021), have more chronic disease comorbidities (OR=1.23, P=0.041), and have more sexual dysfunctions (OR=1.19, P=0.028). Veterans diagnosed with CVD were significantly less likely to report having sex within the previous year (OR=0.53, P=0.005). Veterans who reported discussing sexual issues with a physician were significantly more likely to be ≥75 years (OR=1.79, P=0.010), and report more than a high school education (OR=1.62, P=0.016), CVD diagnosis (OR=1.59, P=0.015), sex within the previous year (OR=1.69, P=0.033), and trouble achieving/maintaining an erection (OR=3.39, P<0.001). These findings suggest older male Veterans, particularly racial/ethnic minorities and those less-educated, may benefit from VA and community-based aging and sexual health/counseling services. These services should promote increased patient-physician communication as well as referrals between physicians and sex health/counseling specialists. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  19. Fabricating Large-Area Sheets of Single-Layer Graphene by CVD

    NASA Technical Reports Server (NTRS)

    Bronikowski, Michael; Manohara, Harish

    2008-01-01

    This innovation consists of a set of methodologies for preparing large area (greater than 1 cm(exp 2)) domains of single-atomic-layer graphite, also called graphene, in single (two-dimensional) crystal form. To fabricate a single graphene layer using chemical vapor deposition (CVD), the process begins with an atomically flat surface of an appropriate substrate and an appropriate precursor molecule containing carbon atoms attached to substituent atoms or groups. These molecules will be brought into contact with the substrate surface by being flowed over, or sprayed onto, the substrate, under CVD conditions of low pressure and elevated temperature. Upon contact with the surface, the precursor molecules will decompose. The substituent groups detach from the carbon atoms and form gas-phase species, leaving the unfunctionalized carbon atoms attached to the substrate surface. These carbon atoms will diffuse upon this surface and encounter and bond to other carbon atoms. If conditions are chosen carefully, the surface carbon atoms will arrange to form the lowest energy single-layer structure available, which is the graphene lattice that is sought. Another method for creating the graphene lattice includes metal-catalyzed CVD, in which the decomposition of the precursor molecules is initiated by the catalytic action of a catalytic metal upon the substrate surface. Another type of metal-catalyzed CVD has the entire substrate composed of catalytic metal, or other material, either as a bulk crystal or as a think layer of catalyst deposited upon another surface. In this case, the precursor molecules decompose directly upon contact with the substrate, releasing their atoms and forming the graphene sheet. Atomic layer deposition (ALD) can also be used. In this method, a substrate surface at low temperature is covered with exactly one monolayer of precursor molecules (which may be of more than one type). This is heated up so that the precursor molecules decompose and form one

  20. Observation of Charge Generation and Transfer during CVD Growth of Carbon Nanotubes.

    PubMed

    Wang, Jiangtao; Liu, Peng; Xia, Bingyu; Wei, Haoming; Wei, Yang; Wu, Yang; Liu, Kai; Zhang, Lina; Wang, Jiaping; Li, Qunqing; Fan, Shoushan; Jiang, Kaili

    2016-07-13

    Carbon nanotube (CNT) is believed to be the most promising material for next generation IC industries with the prerequisite of chirality specific growth. For various approaches to controlling the chiral indices of CNTs, the key is to deepen the understanding of the catalytic growth mechanism in chemical vapor deposition (CVD). Here we show our discovery that the as-grown CNTs are all negatively charged after Fe-catalyzed CVD process. The extra electrons come from the charge generation and transfer during the growth of CNTs, which indicates that an electrochemical process happens in the surface reaction step. We then designed an in situ measurement equipment, verifying that the CVD growth of CNTs can be regarded as a primary battery system. Furthermore, we found that the variation of the Fermi level in Fe catalysts have a significant impact on the chirality of CNTs when different external electric fields are applied. These findings not only provide a new perspective on the growth of CNTs but also open up new possibilities for controlling the growth of CNTs by electrochemical methods.

  1. Chemical composition and bioactivity of Citrus medica L. cv. Diamante essential oil obtained by hydrodistillation, cold-pressing and supercritical carbon dioxide extraction.

    PubMed

    Menichini, Federica; Tundis, Rosa; Bonesi, Marco; de Cindio, Bruno; Loizzo, Monica R; Conforti, Filomena; Statti, Giancarlo A; Menabeni, Roberta; Bettini, Ruggero; Menichini, Francesco

    2011-04-01

    The chemical composition of the essential oil of Citrus medica L. cv. Diamante peel obtained by hydrodistillation, cold-pressing and supercritical carbon dioxide extraction techniques was determined by GC/MS analysis. Forty-six components were fully characterised. Limonene and γ-terpinene were the major components of the oils obtained by hydrodistillation (HD) and cold-pressing (CP), while citropten was the major constituent in the oil obtained by supercritical carbon dioxide extraction (SFE). Acetylcholinesterase (AChE) and butyrylcholinesterase (BChE) inhibitory activities were evaluated. The essential oil obtained by hydrodistillation exerted the highest inhibitory activity against BChE (IC₅₀ value of 154.6 µg mL⁻¹) and AChE (IC₅₀ value of 171.3 µg mL⁻¹. Interestingly, the oil obtained by cold-pressing exhibited a selective inhibitory activity against AChE. The essential oils have also been evaluated for the inhibition of NO production in LPS induced RAW 264.7 macrophages. The oil obtained by hydrodistillation exerted a significant inhibition of NO production with an IC₅₀ value of 17 µg mL⁻¹ (IC₅₀ of positive control 53 µg mL⁻¹).

  2. Pulse height distribution and radiation tolerance of CVD diamond detectors

    NASA Astrophysics Data System (ADS)

    Adam, W.; Berdermann, E.; Bergonzo, P.; Bertuccio, G.; Bogani, F.; Borchi, E.; Brambilla, A.; Bruzzi, M.; Colledani, C.; Conway, J.; Dangelo, P.; Dabrowski, W.; Delpierre, P.; Deneuville, A.; Dulinski, W.; van Eijk, B.; Fallou, A.; Fizzotti, F.; Foulon, F.; Friedl, M.; Gan, K. K.; Gheeraert, E.; Grigoriev, E.; Hallewell, G.; Han, S.; Hartjes, F.; Hrubec, J.; Husson, D.; Kagan, H.; Kania, D.; Kaplon, J.; Karl, C.; Kass, R.; Krammer, M.; Logiudice, A.; Lu, R.; Manfredotti, C.; Meier, D.; Mishina, M.; Moroni, L.; Oh, A.; Pan, L. S.; Pernicka, M.; Peitz, A.; Pirollo, S.; Polesello, P.; Procario, M.; Riester, J. L.; Roe, S.; Rousseau, L.; Rudge, A.; Russ, J.; Sala, S.; Sampietro, M.; Schnetzer, S.; Sciortino, S.; Stelzer, H.; Stone, R.; Suter, B.; Tapper, R. J.; Tesarek, R.; Trawick, M.; Trischuk, W.; Tromson, D.; Vittone, E.; Walsh, A. M.; Wedenig, R.; Weilhammer, P.; White, C.; Zeuner, W.; Zoeller, M.; Fenyvesi, A.; Molnar, J.; Sohler, D.; RD42 Collaboration

    2000-06-01

    The paper reviews measurements of the radiation tolerance of CVD diamond for irradiation with 24 GeV/ c protons, 300 MeV/ c pions and 1 MeV neutrons. For proton and neutron irradiation, the measured charge signal spectrum is compared with the spectrum calculated by a model. Irradiation by particles causes radiation damage leading to a decrease of the charge signal. However, both the measurements and the outcome from the model shows that for tracker applications this drawback is at least partly counterbalanced by a narrowing of the distribution curve of the charge signal. In addition, we observed after proton irradiation at the charge signal spectrum a decrease of the number of small signals. As a result, the efficiency of a CVD diamond tracker is less affected by irradiation than the mean charge signal.

  3. Onset conditions for gas phase reaction and nucleation in the CVD of transition metal oxides

    NASA Technical Reports Server (NTRS)

    Collins, J.; Rosner, D. E.; Castillo, J.

    1992-01-01

    A combined experimental/theoretical study is presented of the onset conditions for gas phase reaction and particle nucleation in hot substrate/cold gas CVD of transition metal oxides. Homogeneous reaction onset conditions are predicted using a simple high activation energy reacting gas film theory. Experimental tests of the basic theory are underway using an axisymmetric impinging jet CVD reactor. No vapor phase ignition has yet been observed in the TiCl4/O2 system under accessible operating conditions (below substrate temperature Tw = 1700 K). The goal of this research is to provide CVD reactor design and operation guidelines for achieving acceptable deposit microstructures at the maximum deposition rate while simultaneously avoiding homogeneous reaction/nucleation and diffusional limitations.

  4. Photochemical CVD of Ru on functionalized self-assembled monolayers from organometallic precursors

    NASA Astrophysics Data System (ADS)

    Johnson, Kelsea R.; Arevalo Rodriguez, Paul; Brewer, Christopher R.; Brannaka, Joseph A.; Shi, Zhiwei; Yang, Jing; Salazar, Bryan; McElwee-White, Lisa; Walker, Amy V.

    2017-02-01

    Chemical vapor deposition (CVD) is an attractive technique for the metallization of organic thin films because it is selective and the thickness of the deposited film can easily be controlled. However, thermal CVD processes often require high temperatures which are generally incompatible with organic films. In this paper, we perform proof-of-concept studies of photochemical CVD to metallize organic thin films. In this method, a precursor undergoes photolytic decomposition to generate thermally labile intermediates prior to adsorption on the sample. Three readily available Ru precursors, CpRu(CO)2Me, (η3-allyl)Ru(CO)3Br, and (COT)Ru(CO)3, were employed to investigate the role of precursor quantum yield, ligand chemistry, and the Ru oxidation state on the deposition. To investigate the role of the substrate chemistry on deposition, carboxylic acid-, hydroxyl-, and methyl-terminated self-assembled monolayers were used. The data indicate that moderate quantum yields for ligand loss (φ ≥ 0.4) are required for ruthenium deposition, and the deposition is wavelength dependent. Second, anionic polyhapto ligands such as cyclopentadienyl and allyl are more difficult to remove than carbonyls, halides, and alkyls. Third, in contrast to the atomic layer deposition, acid-base reactions between the precursor and the substrate are more effective for deposition than nucleophilic reactions. Finally, the data suggest that selective deposition can be achieved on organic thin films by judicious choice of precursor and functional groups present on the substrate. These studies thus provide guidelines for the rational design of new precursors specifically for selective photochemical CVD on organic substrates.

  5. The use of CVD diamond burs for ultraconservative cavity preparations: a report of two cases.

    PubMed

    Carvalho, Carlos Augusto R; Fagundes, Ticiane C; Barata, Terezinha J E; Trava-Airoldi, Vladimir Jesus; Navarro, Maria Fidela L

    2007-01-01

    During the past decades, scientific developments in cutting instruments have changed the conventional techniques used to remove caries lesions. Ultrasound emerged as an alternative for caries removal since the 1950s. However, the conventional technology for diamond powder aggregation with nickel metallic binders could not withstand ultrasonic power. Around 5 years ago, an alternative approach using chemical vapor deposition (CVD) resulted in synthetic diamond technology. CVD diamond burs are obtained with high adherence of the diamond as a unique stone on the metallic surface with excellent abrading performance. This technology allows for diamond deposition with coalescent granulation in different formats of substrates. When connected to an ultrasonic handpiece, CVD diamond burs become an option for cavity preparation, maximizing preservation of tooth structure. Potential advantages such as reduced noise, minimal damage to the gingival tissue, extended bur durability, improved proximal cavity access, reduced risk of hitting the adjacent tooth resulting from the high inclination angles, and minimal patient's risk of metal contamination. These innovative instruments also potentially eliminate some problems regarding decreased cutting efficiency of conventional diamond burs. This clinical report presents the benefits of using CVD diamond burs coupled with an ultrasonic handpiece in the treatment of incipient caries. CVD diamond burs coupled with an ultrasonic device offer a promising alternative for removal of carious lesions when ultraconservative cavity preparations are required. Additionally, this system provides a less-painful technique for caries removal, with minimal noise.

  6. Development of CVD Diamond for Industrial Applications Final Report CRADA No. TC-2047-02

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Caplan, M.; Olstad, R.; Jory, H.

    2017-09-08

    This project was a collaborative effort to develop and demonstrate a new millimeter microwave assisted chemical vapor deposition(CVD) process for manufacturing large diamond disks with greatly reduced processing times and costs from those now available. In the CVD process, carbon based gases (methane) and hydrogen are dissociated into plasma using microwave discharge and then deposited layer by layer as polycrystalline diamond onto a substrate. The available low frequency (2.45GHz) microwave sources used elsewhere (De Beers) result in low density plasmas and low deposition rates: 4 inch diamond disks take 6-8 weeks to process. The new system developed in this projectmore » uses a high frequency 30GHz Gyrotron as the microwave source and a quasi-optical CVD chamber resulting in a much higher density plasma which greatly reduced the diamond processing times (1-2 weeks)« less

  7. iCVD Cyclic Polysiloxane and Polysilazane as Nanoscale Thin-Film Electrolyte: Synthesis and Properties.

    PubMed

    Chen, Nan; Reeja-Jayan, B; Liu, Andong; Lau, Jonathan; Dunn, Bruce; Gleason, Karen K

    2016-03-01

    A group of crosslinked cyclic siloxane (Si-O) and silazane (Si-N) polymers are synthesized via solvent-free initiated chemical vapor deposition (iCVD). Notably, this is the first report of cyclic polysilazanes synthesized via the gas-phase iCVD method. The deposited nanoscale thin films are thermally stable and chemically inert. By iCVD, they can uniformly and conformally cover nonplanar surfaces having complex geometry. Although polysiloxanes are traditionally utilized as dielectric materials and insulators, our research shows these cyclic organosilicon polymers can conduct lithium ions (Li(+) ) at room temperature. The conformal coating and the room temperature ionic conductivity make these cyclic organosilicon polymers attractive for use as thin-film electrolytes in solid-state batteries. Also, their synthesis process and properties have been systemically studied and discussed. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  8. Plasma CVD of hydrogenated boron-carbon thin films from triethylboron

    NASA Astrophysics Data System (ADS)

    Imam, Mewlude; Höglund, Carina; Schmidt, Susann; Hall-Wilton, Richard; Birch, Jens; Pedersen, Henrik

    2018-01-01

    Low-temperature chemical vapor deposition (CVD) of B—C thin films is of importance for neutron voltaics and semiconductor technology. The highly reactive trialkylboranes, with alkyl groups of 1-4 carbon atoms, are a class of precursors that have been less explored for low-temperature CVD of B—C films. Herein, we demonstrate plasma CVD of B—C thin films using triethylboron (TEB) as a single source precursor in an Ar plasma. We show that the film density and B/C ratio increases with increasing plasma power, reaching a density of 2.20 g/cm3 and B/C = 1.7. This is attributed to a more intense energetic bombardment during deposition and more complete dissociation of the TEB molecule in the plasma at higher plasma power. The hydrogen content in the films ranges between 14 and 20 at. %. Optical emission spectroscopy of the plasma shows that BH, CH, C2, and H are the optically active plasma species from TEB. We suggest a plasma chemical model based on β-hydrogen elimination of C2H4 to form BH3, in which BH3 and C2H4 are then dehydrogenated to form BH and C2H2. Furthermore, C2H2 decomposes in the plasma to produce C2 and CH, which together with BH and possibly BH3-x(C2H5)x are the film forming species.

  9. Tribological properties of CVD diamond coated ceramic surfaces

    NASA Astrophysics Data System (ADS)

    Abreu, Cristiano Simoes de

    Recent developments in chemical vapour deposited (CVD) diamond coatings have attracted considerable interest and a host of new applications, each more challenging than the others. This increased attention results from the fact that CVD diamond lms retain to a large extent the outstanding physical and chemical properties of natural single crystal diamond such as extreme hardness, chemical inertness and high corrosion resistance, optical transparency and high thermal conductivity. Diamond features also surprisingly low friction and high wear resistance in unlubricated sliding contacts. Moreover, as opposed to natural diamond where the friction and wear behaviour is highly dependent on crystal orientation, polycrystalline CVD diamond lms supersede the monocrystalline variety due to isotropic tribological properties and possibility of coating complex shapes. Several materials have been tested and more or less successfully used as substrates for CVD diamond coatings. Nonetheless, satisfactory adherence of diamond coatings lms is often only attainable by the use of interlayers, in order to compensate for the large interfacial thermal expansion mismatch between the coating and substrate, which represent an additional processing step and added costs. A promising route will consist in using substrate materials with a low thermal expansion mismatch relative to that of diamond and, therefore, enhanced 1m adhesion. Among these, the ceramic silicon nitride (Si3N4) arises as a serious candidate. As a general rule, available literature regarding the tribological performance of CVD diamond coated Si3N4 lms is scarce, and the few available tribological data only deals with low applied loads. That being said, the correct tribological assessment of CVD diamond coated Si3N4 lms under more realistic sliding conditions, reproducing the stresses found in applications fields such as the fluid handling and metalworking industry, as well as in emerging biotribological areas, is on the

  10. Decreased GFR estimated by MDRD or Cockcroft-Gault equation predicts incident CVD: the strong heart study.

    PubMed

    Shara, Nawar M; Resnick, Helaine E; Lu, Li; Xu, Jiaqiong; Vupputuri, Suma; Howard, Barbara V; Umans, Jason G

    2009-01-01

    Kidney function, expressed as glomerular filtration rate (GFR), is commonly estimated from serum creatinine (Scr) and, when decreased, may serve as a nonclassical risk factor for incident cardiovascular disease (CVD). The ability of estimated GFR (eGFR) to predict CVD events during 5-10 years of follow-up is assessed using data from the Strong Heart Study (SHS), a large cohort with a high prevalence of diabetes. eGFRs were calculated with the abbreviated Modification of Diet in Renal Disease study (MDRD) and the Cockcroft-Gault (CG) equations. These estimates were compared in participants with normal and abnormal Scr. The association between eGFR and incident CVD was assessed. More subjects were labeled as having low eGFR (<60 ml/min per 1.73 m2) by the MDRD or CG equation, than by Scr alone. When Scr was in the normal range, both equations labeled similar numbers of participants as having low eGFRs, although concordance between the equations was poor. However, when Scr was elevated, the MDRD equation labeled more subjects as having low eGFR. Persons with low eGFR had increased risk of CVD. The MDRD and CG equations labeled more participants as having decreased GFR than did Scr alone. Decreased eGFR was predictive of CVD in this American Indian population with a high prevalence of obesity and type 2 diabetes mellitus.

  11. Fabrication of nanostructured electrodes and interfaces using combustion CVD

    NASA Astrophysics Data System (ADS)

    Liu, Ying

    Reducing fabrication and operation costs while maintaining high performance is a major consideration for the design of a new generation of solid-state ionic devices such as fuel cells, batteries, and sensors. The objective of this research is to fabricate nanostructured materials for energy storage and conversion, particularly porous electrodes with nanostructured features for solid oxide fuel cells (SOFCs) and high surface area films for gas sensing using a combustion CVD process. This research started with the evaluation of the most important deposition parameters: deposition temperature, deposition time, precursor concentration, and substrate. With the optimum deposition parameters, highly porous and nanostructured electrodes for low-temperature SOFCs have been then fabricated. Further, nanostructured and functionally graded La0.8Sr0.2MnO2-La 0.8SrCoO3-Gd0.1Ce0.9O2 composite cathodes were fabricated on YSZ electrolyte supports. Extremely low interfacial polarization resistances (i.e. 0.43 Ocm2 at 700°C) and high power densities (i.e. 481 mW/cm2 at 800°C) were generated at operating temperature range of 600°C--850°C. The original combustion CVD process is modified to directly employ solid ceramic powder instead of clear solution for fabrication of porous electrodes for solid oxide fuel cells. Solid particles of SOFC electrode materials suspended in an organic solvent were burned in a combustion flame, depositing a porous cathode on an anode supported electrolyte. Combustion CVD was also employed to fabricate highly porous and nanostructured SnO2 thin film gas sensors with Pt interdigitated electrodes. The as-prepared SnO2 gas sensors were tested for ethanol vapor sensing behavior in the temperature range of 200--500°C and showed excellent sensitivity, selectivity, and speed of response. Moreover, several novel nanostructures were synthesized using a combustion CVD process, including SnO2 nanotubes with square-shaped or rectangular cross sections, well

  12. Thermoelectic properties of CVD grown large area graphene

    NASA Astrophysics Data System (ADS)

    Sherehiy, Andriy

    This thesis is based on experimental work on thermoelectric properties of CVD grown large area graphene. The thermoelectric power (TEP) of CVD (Chemical Vapor Deposition) grown large area graphene transferred onto a Si/SiO 2_substrate was measured by simply attaching two miniature thermocouples and a resistive heater. Availability of such large area graphene facilitates straight forward TEP measurement without the use of any microfabrication processes. All investigated graphene samples showed a positive TEP S ≈ 20 mVK in ambient conditions and saturated at a negative value as low as S ≈ -50 mVK after vacuum-annealing at 500 K in a vacuum of 10-7 Torr. The observed p-type behavior under ambient conditions is attributed to the oxygen doping, while the n-type behavior under degassed conditions is due to electron doping from SiO2 surface states. It was observed that the sign of the TEP switched from negative to positive for the degassed graphene when exposed to acceptor gases. Conversely, the TEP of vacuum-annealed graphene exposed to the donor gases became even more negative than the TEP of vacuum-annealed sample.

  13. Zinc Oxide Grown by CVD Process as Transparent Contact for Thin Film Solar Cell Applications

    NASA Astrophysics Data System (ADS)

    Faÿ, S.; Shah, A.

    Metalorganic chemical vapor deposition of ZnO films (MOCVD) [1] started to be comprehensively investigated in the 1980s, when thin film industries were looking for ZnO deposition processes especially useful for large-scale coatings at high growth rates. Later on, when TCO for thin film solar cells started to be developed, another advantage of growing TCO films by the CVD process has been highlighted: the surface roughness. Indeed, a large number of studies on CVD ZnO revealed that an as-grown rough surface cn be obtained with this deposition process [2-4]. A rough surface induces a light scattering effect, which can significantly improve light trapping (and therefore current photo-generation) within thin film silicon solar cells. The CVD process, indeed, directly leads to as-grown rough ZnO films without any post-etching step (the latter is often introduced to obtain a rough surface, when working with as-deposited flat sputtered ZnO). This fact could turn out to be a significant advantage when upscaling the manufacturing process for actual commercial production of thin film solar modules. The zinc and oxygen sources for CVD growth of ZnO films are given in Table 6.1.

  14. Fish consumption and its motives in households with versus without self-reported medical history of CVD: A consumer survey from five European countries

    PubMed Central

    Pieniak, Zuzanna; Verbeke, Wim; Perez-Cueto, Federico; Brunsø, Karen; De Henauw, Stefaan

    2008-01-01

    Background The purpose of this study was to explore the cross-cultural differences in the frequency of fish intake and in motivations for fish consumption between people from households with (CVD+) or without (CVD-) medical history of cardiovascular disease, using data obtained in five European countries. Methods A cross-sectional consumer survey was carried out in November-December 2004 with representative household samples from Belgium, the Netherlands, Denmark, Poland and Spain. The sample consisted of 4,786 respondents, aged 18–84 and who were responsible for food purchasing and cooking in the household. Results Individuals from households in the CVD+ group consumed fish more frequently in Belgium and in Denmark as compared to those in the CVD- group. The consumption of fatty fish, which is the main sources of omega-3 PUFA associated with prevention of cardiovascular diseases, was on the same level for the two CVD groups in the majority of the countries, except in Belgium where CVD+ subjects reported to eat fatty fish significantly more frequently than CVD- subjects. All respondents perceived fish as a very healthy and nutritious food product. Only Danish consumers reported a higher subjective and objective knowledge related to nutrition issues about fish. In the other countries, objective knowledge about fish was on a low level, similar for CVD+ as for CVD- subjects, despite a higher claimed use of medical information sources about fish among CVD+ subjects. Conclusion Although a number of differences between CVD- and CVD+ subjects with respect to their frequency of fish intake are uncovered, the findings suggest that fish consumption traditions and habits – rather than a medical history of CVD – account for large differences between the countries, particularly in fatty fish consumption. This study exemplifies the need for nutrition education and more effective communication about fish, not only to the people facing chronic diseases, but also to the

  15. A Comparative Study of Three Different Chemical Vapor Deposition (CVD) Techniques of Carbon Nanotube Growth on Diamond Films

    DTIC Science & Technology

    2013-01-01

    FCT-CVD) with xylene and ferrocene liquid mixture without any prior catalyst deposition. T-CVD is a low cost system that can easily be set up to grow...iron catalysts, respectively. For the FCT-CVD approach, ferrocene is used as an iron source to promote CNT growth. Based on these repeatable results...kept at 250 ° C while the high temperature furnace is ramped up to the growth temperature of 750 ° C. Ferrocene was dissolved into xylene solvent in

  16. Alternative group V precursors for CVD applications

    NASA Astrophysics Data System (ADS)

    Lum, R. M.; Klingert, J. K.

    1991-01-01

    The chemical vapor deposition (CVD) techniques used to grow III/V semiconductors films, such as metalorganic vapor phase epitaxy (MOVPE), hydride VPE, chemical beam epitaxy (CBE) and gas source molecular beam epitaxy (GS-MBE), all use hydrides (AsH 3 and PH 3) as the Group V source. However, the hydrides are extremely toxic gases which are stored under high pressure (200-2000 psi). To reduce the safety hazards associated with these gases, alternative Group V precursors have been investigated. Organoarsenic and phosphorous compounds have received the most attention as replacements for AsH 3 and PH 3 because they are typically low vapor pressure liquids, and thus present significantly lower exposure risks than the hydrides. For AsH 3 these have included the methyl, ethyl and butyl-based derivatives RnAsH 3- n, with varying degrees ( n = 1-3) of hydrogen atom substitution. In this paper the growth properties, thermochemistry and toxicity of the various alkylarsine precursors are compared with arsine. Data are presented on the impact of the thermochemistry of these compounds on film electrical properties, and on the effects of precursor composition and purity on overall film quality. The suitability of alternative As-precursors for device applications is demonstrated, and selection criteria are presented for the most effective alkylarsine compound for a particular CVD growth process.

  17. Catalytic CVD synthesis of boron nitride and carbon nanomaterials - synergies between experiment and theory.

    PubMed

    McLean, Ben; Eveleens, Clothilde A; Mitchell, Izaac; Webber, Grant B; Page, Alister J

    2017-10-11

    Low-dimensional carbon and boron nitride nanomaterials - hexagonal boron nitride, graphene, boron nitride nanotubes and carbon nanotubes - remain at the forefront of advanced materials research. Catalytic chemical vapour deposition has become an invaluable technique for reliably and cost-effectively synthesising these materials. In this review, we will emphasise how a synergy between experimental and theoretical methods has enhanced the understanding and optimisation of this synthetic technique. This review examines recent advances in the application of CVD to synthesising boron nitride and carbon nanomaterials and highlights where, in many cases, molecular simulations and quantum chemistry have provided key insights complementary to experimental investigation. This synergy is particularly prominent in the field of carbon nanotube and graphene CVD synthesis, and we propose here it will be the key to future advances in optimisation of CVD synthesis of boron nitride nanomaterials, boron nitride - carbon composite materials, and other nanomaterials generally.

  18. Chemical reactivity of CVC and CVD SiC with UO2 at high temperatures

    NASA Astrophysics Data System (ADS)

    Silva, Chinthaka M.; Katoh, Yutai; Voit, Stewart L.; Snead, Lance L.

    2015-05-01

    Two types of silicon carbide (SiC) synthesized using two different vapor deposition processes were embedded in UO2 pellets and evaluated for their potential chemical reaction with UO2. While minor reactivity between chemical-vapor-composited (CVC) SiC and UO2 was observed at comparatively low temperatures of 1100 and 1300 °C, chemical-vapor-deposited (CVD) SiC did not show any such reactivity. However, both CVD and CVC SiCs showed some reaction with UO2 at a higher temperature (1500 °C). Elemental maps supported by phase maps obtained using electron backscatter diffraction indicated that CVC SiC was more reactive than CVD SiC at 1500 °C. Furthermore, this investigation indicated the formation of uranium carbides and uranium silicide chemical phases such as UC, USi2, and U3Si2 as a result of SiC reaction with UO2.

  19. Synthesis of Different Layers of Graphene on Stainless Steel Using the CVD Method

    NASA Astrophysics Data System (ADS)

    Ghaemi, Ferial; Abdullah, Luqman Chuah; Tahir, Paridah Md; Yunus, Robiah

    2016-11-01

    In this study, different types of graphene, including single-, few-, and multi-layer graphene, were grown on a stainless steel (SS) mesh coated with Cu catalyst by using the chemical vapor deposition (CVD) method. Even though the SS mesh consisted of different types of metals, such as Fe, Ni, and Cr, which can also be used as catalysts, the reason for coating Cu catalyst on the SS surface had been related to the nature of the Cu, which promotes the growth of graphene with high quality and quantity at low temperature and time. The reaction temperature and run time, as the most important parameters of the CVD method, were varied, and thus led to the synthesis of different layers of graphene. Moreover, the presence of single-, few-, and multi-layer graphene was confirmed by employing two techniques, namely transmission electron microscopy (TEM) and Raman spectroscopy. On top of that, electron dispersive X-ray (EDX) was further applied to establish the influence of the CVD parameters on the growth of graphene.

  20. Convection and chemistry effects in CVD: A 3-D analysis for silicon deposition

    NASA Technical Reports Server (NTRS)

    Gokoglu, S. A.; Kuczmarski, M. A.; Tsui, P.; Chait, A.

    1989-01-01

    The computational fluid dynamics code FLUENT has been adopted to simulate the entire rectangular-channel-like (3-D) geometry of an experimental CVD reactor designed for Si deposition. The code incorporated the effects of both homogeneous (gas phase) and heterogeneous (surface) chemistry with finite reaction rates of important species existing in silane dissociation. The experiments were designed to elucidate the effects of gravitationally-induced buoyancy-driven convection flows on the quality of the grown Si films. This goal is accomplished by contrasting the results obtained from a carrier gas mixture of H2/Ar with the ones obtained from the same molar mixture ratio of H2/He, without any accompanying change in the chemistry. Computationally, these cases are simulated in the terrestrial gravitational field and in the absence of gravity. The numerical results compare favorably with experiments. Powerful computational tools provide invaluable insights into the complex physicochemical phenomena taking place in CVD reactors. Such information is essential for the improved design and optimization of future CVD reactors.

  1. Synthesis of Different Layers of Graphene on Stainless Steel Using the CVD Method.

    PubMed

    Ghaemi, Ferial; Abdullah, Luqman Chuah; Tahir, Paridah Md; Yunus, Robiah

    2016-12-01

    In this study, different types of graphene, including single-, few-, and multi-layer graphene, were grown on a stainless steel (SS) mesh coated with Cu catalyst by using the chemical vapor deposition (CVD) method. Even though the SS mesh consisted of different types of metals, such as Fe, Ni, and Cr, which can also be used as catalysts, the reason for coating Cu catalyst on the SS surface had been related to the nature of the Cu, which promotes the growth of graphene with high quality and quantity at low temperature and time. The reaction temperature and run time, as the most important parameters of the CVD method, were varied, and thus led to the synthesis of different layers of graphene. Moreover, the presence of single-, few-, and multi-layer graphene was confirmed by employing two techniques, namely transmission electron microscopy (TEM) and Raman spectroscopy. On top of that, electron dispersive X-ray (EDX) was further applied to establish the influence of the CVD parameters on the growth of graphene.

  2. Radio Frequency Transistors and Circuits Based on CVD MoS2.

    PubMed

    Sanne, Atresh; Ghosh, Rudresh; Rai, Amritesh; Yogeesh, Maruthi Nagavalli; Shin, Seung Heon; Sharma, Ankit; Jarvis, Karalee; Mathew, Leo; Rao, Rajesh; Akinwande, Deji; Banerjee, Sanjay

    2015-08-12

    We report on the gigahertz radio frequency (RF) performance of chemical vapor deposited (CVD) monolayer MoS2 field-effect transistors (FETs). Initial DC characterizations of fabricated MoS2 FETs yielded current densities exceeding 200 μA/μm and maximum transconductance of 38 μS/μm. A contact resistance corrected low-field mobility of 55 cm(2)/(V s) was achieved. Radio frequency FETs were fabricated in the ground-signal-ground (GSG) layout, and standard de-embedding techniques were applied. Operating at the peak transconductance, we obtain short-circuit current-gain intrinsic cutoff frequency, fT, of 6.7 GHz and maximum intrinsic oscillation frequency, fmax, of 5.3 GHz for a device with a gate length of 250 nm. The MoS2 device afforded an extrinsic voltage gain Av of 6 dB at 100 MHz with voltage amplification until 3 GHz. With the as-measured frequency performance of CVD MoS2, we provide the first demonstration of a common-source (CS) amplifier with voltage gain of 14 dB and an active frequency mixer with conversion gain of -15 dB. Our results of gigahertz frequency performance as well as analog circuit operation show that large area CVD MoS2 may be suitable for industrial-scale electronic applications.

  3. Development of CVD-W coatings on CuCrZr and graphite substrates with a PVD intermediate layer

    NASA Astrophysics Data System (ADS)

    Song, Jiupeng; Lian, Youyun; Lv, Yanwei; Liu, Junyong; Yu, Yang; Liu, Xiang; Yan, Binyou; Chen, Zhigang; Zhuang, Zhigang; Zhao, Ximeng; Qi, Yang

    2014-12-01

    In order to apply tungsten (W) coatings by chemical vapor deposition (CVD) for repairing or updating the plasma facing components (PFCs) of the first wall and divertor in existing or future tokomaks, where CuCrZr or graphite is the substrate material, an intermediate layer by physical vapor deposition (PVD) has been used to accommodate the interface stress due to the mismatch of thermal expansion or act as a diffusion barrier between the CVD-W coating and the substrate. The prepared CuCrZr/PVD-Cu/CVD-W sample with active cooling has passed thermal fatigue tests by electron beam with an absorbed power of 2.2 MW/m2, 50 s on/50 s off, for 100 cycles. Another graphite/PVD-Si/CVD-W sample without active cooling underwent thermal fatigue testing with an absorbed power density of 4.62 MW/m2, 5 s on/25 s off, for 200 cycles, and no catastrophic failure was found.

  4. Are drivers with CVD more at risk for motor vehicle crashes? Study of men aged 45 to 70.

    PubMed Central

    Guibert, R.; Potvin, L.; Ciampi, A.; Loiselle, J.; Philibert, L.; Franco, E. D.

    1998-01-01

    OBJECTIVE: To examine whether male drivers aged 45 to 70 years suffering from cardiovascular disease (CVD) are more likely to be involved in motor vehicle crashes (MVC) that are reported to the police. DESIGN: Population-based case-control study. SETTING: Data on drivers' ages and medical conditions were compiled from the Societé de l'assurance automobile du Québec's (SAAQ) computerized files. A questionnaire was mailed to all subjects to collect additional information on annual distances driven and various driving behaviours. PARTICIPANTS: Age-stratified population-based random sample. Subjects were 2504 drivers involved in MVCs during a 6-month period; controls were 2520 drivers not involved in crashes. MAIN OUTCOME MEASURES: Proportion of drivers with CVD involved in MVCs. RESULTS: Response rate to the questionnaire was 35.5%. Analysis of the SAAQ files' entire sample of 5024 drivers showed that drivers suffering from CVD were less likely to be involved in MVCs (odds ratio [OR] 0.82, 95% confidence interval [CI] 0.67 to 0.99) than drivers without CVD. Although the estimate of risk remains unchanged when adjusted for age, it becomes statistically insignificant. It also remains unchanged and statistically insignificant when adjusted for yearly distance driven and driver behaviour, as shown by responses to the questionnaire. Drivers suffering from CVD drove significantly less each year (8900 km) than drivers without medical conditions (13,000 km). CONCLUSION: This study shows no increased risk of motor vehicle crashes for drivers suffering from CVD. PMID:9585850

  5. CVD SiC deformable mirror with monolithic cooling channels.

    PubMed

    Ahn, Kyohoon; Rhee, Hyug-Gyo; Yang, Ho-Soon; Kihm, Hagyong

    2018-04-16

    We propose a novel deformable mirror (DM) for adaptive optics in high power laser applications. The mirror is made of a Silicon carbide (SiC) faceplate, and cooling channels are embedded monolithically inside the faceplate with the chemical vapor desposition (CVD) method. The faceplate is 200 mm in diameter and 3 mm in thickness, and is actuated by 137 stack-type piezoelectric transducers arranged in a square grid. We also propose a new actuator influence function optimized for modelling our DM, which has a relatively stiffer faceplate and a higher coupling ratio compared with other DMs having thin faceplates. The cooling capability and optical performance of the DM are verified by simulations and actual experiments with a heat source. The DM is proved to operate at 1 kHz without the coolant flow and 100 Hz with the coolant flow, and the residual errors after compensation are less than 30 nm rms (root-mean-square). This paper presents the design, fabrication, and optical performance of the CVD SiC DM.

  6. Chemical reactivity of CVC and CVD SiC with UO 2 at high temperatures

    DOE PAGES

    Silva, Chinthaka M.; Katoh, Yutai; Voit, Stewart L.; ...

    2015-02-11

    Two types of silicon carbide (SiC) synthesized using two different vapor deposition processes were embedded in UO 2 pellets and evaluated for their potential chemical reaction with UO 2. While minor reactivity between chemical-vapor-composited (CVC) SiC and UO 2 was observed at comparatively low temperatures of 1100 and 1300 C, chemical-vapor-deposited (CVD) SiC did not show any such reactivity, according to microstructural investigations. But, both CVD and CVC SiCs showed some reaction with UO 2 at a higher temperature (1500 C). Elemental maps supported by phase maps obtained using electron backscatter diffraction indicated that CVC SiC was more reactive thanmore » CVD SiC at 1500 C. Moreover, this investigation indicated the formation of uranium carbides and uranium silicide chemical phases such as UC, USi 2, and U 3Si 2 as a result of SiC reaction with UO 2.« less

  7. Dietary patterns and the risk of CVD and all-cause mortality in older British men.

    PubMed

    Atkins, Janice L; Whincup, Peter H; Morris, Richard W; Lennon, Lucy T; Papacosta, Olia; Wannamethee, S Goya

    2016-10-01

    Dietary patterns are a major risk factor for cardiovascular morbidity and mortality; however, few studies have examined this relationship in older adults. We examined prospective associations between dietary patterns and the risk of CVD and all-cause mortality in 3226 older British men, aged 60-79 years and free from CVD at baseline, from the British Regional Heart Study. Baseline FFQ data were used to generate thirty-four food groups. Principal component analysis identified dietary patterns that were categorised into quartiles, with higher quartiles representing higher adherence to the dietary pattern. Cox proportional hazards examined associations between dietary patterns and risk of all-cause mortality and cardiovascular outcomes. We identified three interpretable dietary patterns: 'high fat/low fibre' (high in red meat, meat products, white bread, fried potato, eggs), 'prudent' (high in poultry, fish, fruits, vegetables, legumes, pasta, rice, wholemeal bread, eggs, olive oil) and 'high sugar' (high in biscuits, puddings, chocolates, sweets, sweet spreads, breakfast cereals). During 11 years of follow-up, 899 deaths, 316 CVD-related deaths, 569 CVD events and 301 CHD events occurred. The 'high-fat/low-fibre' dietary pattern was associated with an increased risk of all-cause mortality only, after adjustment for confounders (highest v. lowest quartile; hazard ratio 1·44; 95 % CI 1·13, 1·84). Adherence to a 'high-sugar' diet was associated with a borderline significant trend for an increased risk of CVD and CHD events. The 'prudent' diet did not show a significant trend with cardiovascular outcomes or mortality. Avoiding 'high-fat/low-fibre' and 'high-sugar' dietary components may reduce the risk of cardiovascular events and all-cause mortality in older adults.

  8. System for the growth of bulk SiC crystals by modified CVD techniques

    NASA Technical Reports Server (NTRS)

    Steckl, Andrew J.

    1994-01-01

    The goal of this program was the development of a SiC CVD growth of films thick enough to be useful as pseudo-substrates. The cold-walled CVD system was designed, assembled, and tested. Extrapolating from preliminary evaluation of SiC films grown in the system at relatively low temperatures indicates that the growth rate at the final temperatures will be high enough to make our approach practical. Modifications of the system to allow high temperature growth and cleaner growth conditions are in progress. This program was jointly funded by Wright Laboratory, Materials Directorate and NASA LeRC and monitored by NASA.

  9. CVD Rhenium Engines for Solar-Thermal Propulsion Systems

    NASA Technical Reports Server (NTRS)

    Williams, Brian E.; Fortini, Arthur J.; Tuffias, Robert H.; Duffy, Andrew J.; Tucker, Stephen P.

    1999-01-01

    Solar-thermal upper-stage propulsion systems have the potential to provide specific impulse approaching 900 seconds, with 760 seconds already demonstrated in ground testing. Such performance levels offer a 100% increase in payload capability compared to state-of-the-art chemical upper-stage systems, at lower cost. Although alternatives such as electric propulsion offer even greater performance, the 6- to 18- month orbital transfer time is a far greater deviation from the state of the art than the one to two months required for solar propulsion. Rhenium metal is the only material that is capable of withstanding the predicted thermal, mechanical, and chemical environment of a solar-thermal propulsion device. Chemical vapor deposition (CVD) is the most well-established and cost-effective process for the fabrication of complex rhenium structures. CVD rhenium engines have been successfully constructed for the Air Force ISUS program (bimodal thrust/electricity) and the NASA Shooting Star program (thrust only), as well as under an Air Force SBIR project (thrust only). The bimodal engine represents a more long-term and versatile approach to solar-thermal propulsion, while the thrust-only engines provide a potentially lower weight/lower cost and more near-term replacement for current upper-stage propulsion systems.

  10. Comparative study of passively Q-switched c-cut Nd:YVO4/Nd:YAG lasers based on CVD graphene and controlled operation

    NASA Astrophysics Data System (ADS)

    Jia, Fuqiang; Liu, Pei; Li, Kang; Chen, Hao; Cheng, Yongjie; Cai, Zhiping; Copner, Nigel

    2017-07-01

    In this paper, a comparative study of passively Q-switched c-cut Nd:YVO4 and Nd:YAG lasers using four different layers CVD graphene as saturable absorber are demonstrated experimentally for the first time. Moreover, it is successful to accurately control the frequency of repetition rates of the CVD graphern passively Q-switched lasers by pulsed pump. The impacts of laser materials, layers of CVD graphene and cavity length on output parameters are investigated intensively as well, the result shows that the c-cut Nd:YVO4 is a promising laser media compared with Nd:YAG for passively Q-switched lasers based on CVD graphene, as it has better performances in pulse width, pulse energy and peak power. A useful and cost-effective way to generate stable pulsed lasers by CVD graphene or other novel saturable materials are demonstrated.

  11. A Conceptual Framework for Barriers to the Recruitment and Retention of Rural CVD Participants in Behavior Intervention Trials.

    PubMed

    Young, Lufei; Montgomery, Melody; Barnason, Sue; Schmidt, Cindy; Do, Van

    2015-08-01

    Rural residents diagnosed with cardiovascular disease (CVD) or with CVD-related risks are underrepresented in behavioral intervention trials based on an extensive review of published studies. The low participation rate of rural residents weakens both the internal and external validity of published studies. Moreover, compared to urban residents, limited research exists to describe the unique barriers that limit the participation of rural residents in behavioral intervention trials. The purpose of this review is to identify a conceptual framework (CF) underpinning common barriers faced by rural CVD patients to enroll in behavioral intervention trials. We conducted a literature review using several electronic databases to obtain a representative sample of research articles, synthesized the evidence, and developed a CF to explain the barriers that may affect the research participation rate of rural residents with CVD or related risks. We found our evidence-based CF well explained the barriers for rural CVD patients to take part in behavioral intervention trials. Besides contextual factors (i.e. patient, community and research levels), other common factors impacting rural patients' intent to enroll are lack of awareness and understanding about behavioral trials, limited support from their healthcare providers and social circles, unfavorable attitudes, and the lack of opportunity to participating research. The findings demonstrate the evidence-based model consisting of interlinked multi-level factors may help our understanding of the barriers encountered by rural CVD patients participating interventions to promote behavioral change. The implication for researchers is that identifying and developing strategies to overcome the barriers precedes conducting studies in rural communities.

  12. Low-temperature growth of nitrogen-doped carbon nanofibers by acetonitrile catalytic CVD using Ni-based catalysts

    NASA Astrophysics Data System (ADS)

    Iwasaki, Tomohiro; Makino, Yuri; Fukukawa, Makoto; Nakamura, Hideya; Watano, Satoru

    2016-11-01

    To synthesize nitrogen-doped carbon nanofibers (N-CNFs) at high growth rates and low temperatures less than 673 K, nickel species (metallic nickel and nickel oxide) supported on alumina particles were used as the catalysts for an acetonitrile catalytic chemical vapor deposition (CVD) process. The nickel:alumina mass ratio in the catalysts was fixed at 0.05:1. The catalyst precursors were prepared from various nickel salts (nitrate, chloride, sulfate, acetate, and lactate) and then calcined at 1073 K for 1 h in oxidative (air), reductive (hydrogen-containing argon), or inert (pure argon) atmospheres to activate the nickel-based catalysts. The effects of precursors and calcination atmosphere on the catalyst activity at low temperatures were studied. We found that the catalysts derived from nickel nitrate had relatively small crystallite sizes of nickel species and provided N-CNFs at high growth rates of 57 ± 4 g-CNF/g-Ni/h at 673 K in the CVD process using 10 vol% hydrogen-containing argon as the carrier gas of acetonitrile vapor, which were approximately 4 times larger than that of a conventional CVD process. The obtained results reveal that nitrate ions in the catalyst precursor and hydrogen in the carrier gas can contribute effectively to the activation of catalysts in low-temperature CVD. The fiber diameter and nitrogen content of N-CNFs synthesized at high growth rates were several tens of nanometers and 3.5 ± 0.3 at.%, respectively. Our catalysts and CVD process may lead to cost reductions in the production of N-CNFs.

  13. Thin CVD-diamond RF Pill-Box vacuum windows for LHCD systems

    NASA Astrophysics Data System (ADS)

    Ravera, G. L.; Ceccuzzi, S.; Cardinali, A.; Cesario, R.; Mirizzi, F.; Schettini, G.; Tuccillo, A. A.

    2014-02-01

    The preliminary assessment of a Lower Hybrid Current Drive (LHCD) system for the DEMOnstration power plant (DEMO) is mainly focused on the R&D needs of the less conventional RF components of the Main Transmission Line (MTL) and of the launcher. 500 kW, CW klystrons will be used to deliver the RF power to independent Passive Active Multijunction (PAM) launcher modules at 5 GHz. This paper describes the criteria followed to investigate the optimum solution for the RF window used as vacuum barrier between the MTL and the launcher, an open issue in the LHCD system for ITER too. The best candidate, capable of withstanding a power level of, or above, 0.5 MW in CW operation and to satisfy the electrical and thermonuclear requirements, is a Pill-Box assembly, based on a thin single disk of CVD-diamond as dielectric, water cooled at the edge. A thickness of 3 mm, much shorter than half a wavelength of the TE°11 mode in the dielectric as in the conventional window (unfeasible and too expensive with CVD-diamond at these frequencies), is sufficient to limit the exerted stress at the edge under the fracture stress for a maximum pressure applied of 0.9 MPa. In this paper the simulation results of conventional and thin CVD-diamond vacuum windows are presented comparing S-parameters, losses and electric fields in both matching condition and with VSWR = 2, using WR284 and WR229 as input/output rectangular waveguide.

  14. Observation of twinning in diamond CVD films

    NASA Astrophysics Data System (ADS)

    Marciniak, W.; Fabisiak, K.; Orzeszko, S.; Rozploch, F.

    1992-10-01

    Diamond particles prepared by dc-glow-discharge enhanced HF-CVD hybrid method, from a mixture of acetone vapor and hydrogen gas have been examined by TEM, RHEED and dark field method of observation. Results suggest the presence of twinned diamond particles, which can be reconstructed by a sequence of twinning operations. Contrary to the 'stick model' of the lattice, very common five-fold symmetry of diamond microcrystals may be obtained by applying a number of edge dislocations rather than the continuous deformation of many tetrahedral C-C bonds.

  15. Preparation and properties of CVD-graphene/AgNWs hybrid transparent electrodes for the application of flexible optoelectronic devices

    NASA Astrophysics Data System (ADS)

    Wang, Xue-yan; Bao, Jun; Li, Lu; Cui, Shao-li; Du, Xiao-qing

    2017-10-01

    The flexible electrodes based on CVD-graphene/ AgNWs hybrid transparent films were prepared by the vacuum filtration and substrate transferring method, and several performances of the films including sheet resistance, optical transmittance, work function, surface roughness and flexibility were further researched. The results suggested that the hybrid films which were obtained by vacuum filtration and substrate transferring method have the advantages such as uniform distribution of AgNWs, high work function, low roughness and small sheet resistance and good flexibility. The sheet resistance of the hybrid films would decrease with the increasing of the concentration of AgNWs, while the surface roughness would increase and the optical transmittance at 550nm of the films decrease linearly. Organic light emitting devices (OLED) devices based on CVD-graphene/AgNWs hybrid films were fabricated, and characteristics of voltage-current density, luminance, current efficiency were tested. It's found that CVD-graphene/AgNWs hybrid films were better than CVD-graphene films when they were used as anodes for organic light emitting devices. It can be seen that CVD-graphene/AgNWs hybrid transparent films have great potential in applications of flexible electrodes, and are of great significance for promoting the development of organic light emitting devices.

  16. Proton irradiation of CVD diamond detectors for high-luminosity experiments at the LHC

    NASA Astrophysics Data System (ADS)

    Meier, D.; Adam, W.; Bauer, C.; Berdermann, E.; Bergonzo, P.; Bogani, F.; Borchi, E.; Bruzzi, M.; Colledani, C.; Conway, J.; Dabrowski, W.; Delpierre, P.; Deneuville, A.; Dulinski, W.; van Eijk, B.; Fallou, A.; Foulon, F.; Friedl, M.; Jany, C.; Gan, K. K.; Gheeraert, E.; Grigoriev, E.; Hallewell, G.; Hall-Wilton, R.; Han, S.; Hartjes, F.; Hrubec, J.; Husson, D.; Kagan, H.; Kania, D.; Kaplon, J.; Kass, R.; Knöpfle, K. T.; Krammer, M.; Manfredi, P. F.; Marshall, R. D.; Mishina, M.; Le Normand, F.; Pan, L. S.; Palmieri, V. G.; Pernegger, H.; Pernicka, M.; Peitz, A.; Pirollo, S.; Pretzl, K.; Re, V.; Riester, J. L.; Roe, S.; Roff, D.; Rudge, A.; Schnetzer, S.; Sciortino, S.; Speziali, V.; Stelzer, H.; Stone, R.; Tapper, R. J.; Tesarek, R.; Thomson, G. B.; Trawick, M.; Trischuk, W.; Turchetta, R.; Walsh, A. M.; Wedenig, R.; Weilhammer, P.; Ziock, H.; Zoeller, M.; RD42 Collaboration

    1999-04-01

    CVD diamond shows promising properties for use as a position-sensitive detector for experiments in the highest radiation areas at the Large Hadron Collider. In order to study the radiation hardness of diamond we exposed CVD diamond detector samples to 24 Gev/ c and 500 Mev protons up to a fluence of 5×10 15 p/cm 2. We measured the charge collection distance, the average distance electron-hole pairs move apart in an external electric field, and leakage currents before, during, and after irradiation. The charge collection distance remains unchanged up to 1×10 15 p/cm 2 and decreases by ≈40% at 5×10 15 p/cm 2. Leakage currents of diamond samples were below 1 pA before and after irradiation. The particle-induced currents during irradiation correlate well with the proton flux. In contrast to diamond, a silicon diode, which was irradiated for comparison, shows the known large increase in leakage current. We conclude that CVD diamond detectors are radiation hard to 24 GeV/ c and 500 MeV protons up to at least 1×10 15p/cm 2 without signal loss.

  17. Co-morbid depression is associated with poor work outcomes in persons with cardiovascular disease (CVD): A large, nationally representative survey in the Australian population

    PubMed Central

    2012-01-01

    Background Co-morbid major depressive disorder (MDD) and cardiovascular disease (CVD) is associated with poor clinical and psychological outcomes. However, the full extent of the burden of, and interaction between, this co-morbidity on important vocational outcomes remains less clear, particularly at the population level. We examine the association of co-morbid MDD with work outcomes in persons with and without CVD. Methods This study utilised cross-sectional, population-based data from the 2007 Australian National Survey of Mental Health and Wellbeing (n = 8841) to compare work outcomes of individuals with diagnostically-defined MDD and CVD, MDD but not CVD, CVD but not MDD, with a reference group of "healthy" Australians. Workforce participation was defined as being in full- or part-time employment. Work functioning was measured using a WHO Disability Assessment Schedule item. Absenteeism was assessed using the 'days out of role' item. Results Of the four groups, those with co-morbid MDD and CVD were least likely to report workforce participation (adj OR:0.4, 95% CI: 0.3-0.6). Those with MDD only (adj OR:0.8, 95% CI:0.7-0.9) and CVD only (adj OR:0.8, 95% CI: 0.6-0.9) also reported significantly reduced odds of participation. Employed individuals with co-morbid MDD and CVD were 8 times as likely to experience impairments in work functioning (adj OR:8.1, 95% CI: 3.8- 17.3) compared with the reference group. MDD was associated with a four-fold increase in impaired functioning. Further, individuals with co-morbid MDD and CVD reported greatest likelihood of workplace absenteeism (adj. OR:3.0, 95% CI: 1.4-6.6). Simultaneous exposure to MDD and CVD conferred an even greater likelihood of poorer work functioning. Conclusions Co-morbid MDD and CVD is associated with significantly poorer work outcomes. Specifically, the effects of these conditions on work functioning are synergistic. The development of specialised treatment programs for those with co-morbid MDD and CVD is

  18. VOx effectively doping CVD-graphene for transparent conductive films

    NASA Astrophysics Data System (ADS)

    Ji, Qinghua; Shi, Liangjing; Zhang, Qinghong; Wang, Weiqi; Zheng, Huifeng; Zhang, Yuzhi; Liu, Yangqiao; Sun, Jing

    2016-11-01

    Chemical vapor deposition(CVD)-synthesized graphene is potentially an alternative for tin-doped indium oxide (ITO) transparent conductive films (TCFs), however its sheet resistance is still too high to meet many demands. Vanadium oxide has been widely applied as smart window materials, however, no study has been reported to use it as dopant to improve the conductivity of graphene TCFs. In this study, we firstly reported that VOx doping can effectively lower the sheet resistance of CVD-graphene films while keeping its good optical properties, whose transmittance is as high as 86-90%. The optimized VOx-doped graphene exhibits a sheet resistance as low as 176 Ω/□, which decreases by 56% compared to the undoped graphene films. The doping process is convenient, stable, economical and easy to operate. What is more, VOx can effectively increase the work function(WF) of the film, making it more appropriate for use in solar cells. The evolution of the VOx species annealed at different temperatures below 400 °C has been detailed studied for the first time, based on which the doping mechanism is proposed. The prepared VOx doped graphene is expected to be a promising candidate for transparent conductive film purposes.

  19. AuCl3 doping-induced conductive unstability for CVD-grown graphene on glass substrate

    NASA Astrophysics Data System (ADS)

    Wang, Jiaqing; Liu, Xianming; Cao, Xueying; Zhang, Peng; Lei, Xiaohua; Chen, Weimin

    2017-09-01

    Graphene is a candidate material for next-generation high performance transparent conducting film (TCF) to replace indium tin oxide (ITO) materials. However, the sheet resistance of large area graphene obtained by the chemical vapor deposition (CVD) method is higher than other kinds of TCFs. The main strategies for improving the electrical conductivity of graphene films have been based on various doping treatments. AuCl3 is one of the most effective dopants. In this paper, we investigate the influence of AuCl3 doping on the conductive stability of CVD-grown graphene. Large area graphene film synthesized by CVD and transferred to glass substrates is taken as experimental sample. AuCl3 in nitromethane is used to dope the graphene films to improve the electrical conductivity. Another sample without doping is prepared for comparison. The resistances of graphene under periodic visible light irradiation with and without AuCl3 doping are measured. Results show that the resistances for all samples increase exponentially under lighting, while decrease slowly in an exponential form as well after the light is switched off. The relative resistance changes for undoped and doped samples are compared under 445nm light irradiation with 40mW/cm2, 60mW/cm2, 80mW/cm2, 100mW/cm2 in atmosphere and vacuum. The change rate and degree for doped graphene are greater than that of undoped graphene. It is evident from the experimental data that AuCl3 doping may induce conductive unstability for CVD-grown graphene on glass substrate.

  20. A comparative study of the thermoluminescent response to beta irradiation of CVD diamond and LiF dosimeters

    NASA Astrophysics Data System (ADS)

    Bogani, F.; Borchi, E.; Bruzzi, M.; Leroy, C.; Sciortino, S.

    1997-02-01

    The thermoluminescent (TL) response of Chemical Vapour Deposited (CVD) diamond films to beta irradiation has been investigated. A numerical curve-fitting procedure, calibrated by means of a set of LiF TLD100 experimental spectra, has been developed to deconvolute the complex structured TL glow curves. The values of the activation energy and of the frequency factor related to each of the TL peaks involved have been determined. The TL response of the CVD diamond films to beta irradiation has been compared with the TL response of a set of LiF TLD100 and TLD700 dosimeters. The results have been discussed and compared in view of an assessment of the efficiency of CVD diamond films in future applications as in vivo dosimeters.

  1. Greater flavonoid intake is associated with improved CVD risk factors in US adults.

    PubMed

    Kim, Kijoon; Vance, Terrence M; Chun, Ock K

    2016-04-01

    Epidemiological studies have reported that diets high in flavonoids are associated with a reduced risk of CVD. However, evidence on the association of dietary flavonoid intake with CVD risk factors is still scarce. The present study aimed to investigate the association of dietary flavonoid intake with CVD risk factors among US adults in the National Health and Nutrition Examination Survey (NHANES) 2007-2012. A total of 4042 US adults aged 19 years and older from the NHANES 2007-2012 participated in this cross-sectional, population-based study. Intakes of total and individual flavonoids were estimated from 2-d 24-h diet recall data by matching with the expanded US Department of Agriculture flavonoid, isoflavone and proanthocyanidin databases. After adjusting for covariates, increased HDL-cholesterol was associated with higher total flavonoid intake (0·54 % change). TAG and TAG:HDL-cholesterol ratio were inversely associated with anthocyanidin (-1·25 % change for TAG; -1·60 % change for TAG:HDL-cholesterol ratio) and total flavonoid intakes (-1·31 % change for TAG; -1·83 % change for TAG:HDL-cholesterol ratio), respectively. Insulin and homoeostasis model assessment for insulin resistance (HOMA-IR) were inversely associated with flavone (for insulin, -3·18 % change; 95 % CI -5·85, -0·44; for HOMA-IR, -3·10 % change; 95 % CI -5·93, -0·19) and isoflavone intakes (for insulin, -3·11 % change; 95 % CI -5·46, -0·70; for HOMA-IR, -4·01 % change; 95 % CI -6·67, -1·27). BMI was negatively associated with anthocyanidin intake (-0·60 % change). This study showed that higher flavonoid intake was associated with improved CVD risk factors. Further research is warranted to confirm the findings from this study as these associations were moderate in strength.

  2. CVD of silicon carbide on structural fibers - Microstructure and composition

    NASA Technical Reports Server (NTRS)

    Veitch, Lisa C.; Terepka, Francis M.; Gokoglu, Suleyman A.

    1992-01-01

    Structural fibers are currently being considered as reinforcements for intermetallic and ceramic materials. Some of these fibers, however, are easily degraded in a high temperature oxidative environment. Therefore, coatings are needed to protect the fibers from environmental attack. Silicon carbide (SiC) was chemically vapor deposited (CVD) on Textron's SCS6 fibers. Fiber temperatures ranging from 1350 to 1500 C were studied. Silane (SiH4) and propane (C2H8) were used for the source gases and different concentrations of these source gases were studied. Deposition rates were determined for each group of fibers at different temperatures. Less variation in deposition rates were observed for the dilute source gas experiments than the concentrated source gas experiments. A careful analysis was performed on the stoichiometry of the CVD SiC coating using electron microprobe. Microstructures for the different conditions were compared. At 1350 C, the microstructures were similar; however, at higher temperatures, the microstructure for the more concentrated source gas group were porous and columnar in comparison to the cross sections taken from the same area for the dilute source gas group.

  3. CVD of silicon carbide on structural fibers: Microstructure and composition

    NASA Technical Reports Server (NTRS)

    Veitch, Lisa C.; Terepka, Francis M.; Gokoglu, Suleyman A.

    1992-01-01

    Structural fibers are currently being considered as reinforcements for intermetallic and ceramic materials. Some of these fibers, however, are easily degraded in a high temperature oxidative environment. Therefore, coatings are needed to protect the fibers from environmental attack. Silicon carbide (SiC) was chemically vapor deposited (CVD) on Textron's SCS6 fibers. Fiber temperatures ranging from 1350 to 1500 C were studied. Silane (SiH4) and propane (C2H8) were used for the source gases and different concentrations of these source gases were studied. Deposition rates were determined for each group of fibers at different temperatures. Less variation in deposition rates were observed for the dilute source gas experiments than the concentrated source gas experiments. A careful analysis was performed on the stoichiometry of the CVD SiC coating using electron microprobe. Microstructures for the different conditions were compared. At 1350 C, the microstructures were similar; however, at higher temperatures, the microstructure for the more concentrated source gas group were porous and columnar in comparison to the cross sections taken from the same area for the dilute source gas group.

  4. Comparison of tungsten films grown by CVD and hot-wire assisted atomic layer deposition in a cold-wall reactor

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yang, Mengdi, E-mail: M.Yang@utwente.nl; Aarnink, Antonius A. I.; Kovalgin, Alexey Y.

    2016-01-15

    In this work, the authors developed hot-wire assisted atomic layer deposition (HWALD) to deposit tungsten (W) with a tungsten filament heated up to 1700–2000 °C. Atomic hydrogen (at-H) was generated by dissociation of molecular hydrogen (H{sub 2}), which reacted with WF{sub 6} at the substrate to deposit W. The growth behavior was monitored in real time by an in situ spectroscopic ellipsometer. In this work, the authors compare samples with tungsten grown by either HWALD or chemical vapor deposition (CVD) in terms of growth kinetics and properties. For CVD, the samples were made in a mixture of WF{sub 6} and molecularmore » or atomic hydrogen. Resistivity of the WF{sub 6}-H{sub 2} CVD layers was 20 μΩ·cm, whereas for the WF{sub 6}-at-H-CVD layers, it was 28 μΩ·cm. Interestingly, the resistivity was as high as 100 μΩ·cm for the HWALD films, although the tungsten films were 99% pure according to x-ray photoelectron spectroscopy. X-ray diffraction reveals that the HWALD W was crystallized as β-W, whereas both CVD films were in the α-W phase.« less

  5. Which population groups are most unaware of CVD risks associated with sitting time?

    PubMed

    Duncan, Mitch J; Gilson, Nicholas; Vandelanotte, Corneel

    2014-08-01

    Prolonged sitting is an emerging risk factor for poor health yet few studies have examined awareness of the risks associated with sitting behaviours. This study identifies the population subgroups with the highest levels of unawareness regarding the cardiovascular disease (CVD) risks associated with sitting behaviours. Adults (n=1256) living in Queensland, Australia completed a telephone-based survey in 2011, analysis conducted in 2013. The survey assessed participant's socio-demographic characteristics, physical activity, sitting behaviours and awareness of CVD risks associated with three sitting behaviours: 1) sitting for prolonged periods, 2), sitting for prolonged periods whilst also engaging in regular physical activity, and 3) breaking up periods of prolonged sitting with short activity breaks. Population sub-groups with the highest levels of unawareness were identified based on socio-demographic and behavioural characteristics using signal detection analysis. Unawareness ranged from 23.3% to 67.0%. Age was the most important variable in differentiating awareness levels; younger adults had higher levels of unawareness. Body mass index, physical activity, TV viewing, employment status and time spent at work also identified population sub-groups. Unawareness of CVD risk for prolonged sitting was moderately high overall. Younger adults had high levels of unawareness on all of the outcomes examined. Copyright © 2014 Elsevier Inc. All rights reserved.

  6. The training and fieldwork experiences of community health workers conducting population-based, noninvasive screening for CVD in LMIC.

    PubMed

    Abrahams-Gessel, Shafika; Denman, Catalina A; Montano, Carlos Mendoza; Gaziano, Thomas A; Levitt, Naomi; Rivera-Andrade, Alvaro; Carrasco, Diana Munguía; Zulu, Jabu; Khanam, Masuma Akter; Puoane, Thandi

    2015-03-01

    Cardiovascular disease (CVD) is on the rise in low- and middle-income countries and is proving difficult to combat due to the emphasis on improving outcomes in maternal and child health and infectious diseases against a backdrop of severe human resource and infrastructure constraints. Effective task-sharing from physicians or nurses to community health workers (CHW) to conduct population-based screening for persons at risk has the potential to mitigate the impact of CVD on vulnerable populations. CHW in Bangladesh, Guatemala, Mexico, and South Africa were trained to conduct noninvasive population-based screening for persons at high risk for CVD. This study sought to quantitatively assess the performance of CHW during training and to qualitatively capture their training and fieldwork experiences while conducting noninvasive screening for CVD risk in their communities. Written tests were used to assess CHW's acquisition of content knowledge during training, and focus group discussions were conducted to capture their training and fieldwork experiences. Training was effective at increasing the CHW's content knowledge of CVD, and this knowledge was largely retained up to 6 months after the completion of fieldwork. Common themes that need to be addressed when designing task-sharing with CHW in chronic diseases are identified, including language, respect, and compensation. The importance of having intimate knowledge of the community receiving services from design to implementation is underscored. Effective training for screening for CVD in community settings should have a strong didactic core that is supplemented with culture-specific adaptations in the delivery of instruction. The incorporation of expert and intimate knowledge of the communities themselves is critical, from the design to implementation phases of training. Challenges such as role definition, defining career paths, and providing adequate remuneration must be addressed. Copyright © 2015 World Heart

  7. Influence of CVD diamond tips and Er:YAG laser irradiation on bonding of different adhesive systems to dentin.

    PubMed

    da Silva, Melissa Aline; Di Nicolo, Rebeca; Barcellos, Daphne Camara; Batista, Graziela Ribeiro; Pucci, Cesar Rogerio; Rocha Gomes Torres, Carlos; Borges, Alessandra Bühler

    2013-01-01

    The aim of this study was to compare the microtensile bond strength of three adhesive systems, using different methods of dentin preparation. A hundred and eight bovine teeth were used. The dentin from buccal face was exposed and prepared with three different methods, divided in 3 groups: Group 1 (DT)- diamond tip on a high-speed handpiece; Group 2 (CVD)-CVD tip on a ultrasonic handpiece; Group 3 (LA)-Er: YAG laser. The teeth were divided into 3 subgroups, according adhesive systems used: Subgroup 1-Adper Single Bond Plus/3M ESPE (SB) total-etch adhesive; Subgroup 2-Adper Scotchbond SE/3M ESPE (AS) selfetching adhesive; Subgroup 3-Clearfil SE Bond/Kuraray (CS) selfetching adhesive. Blocks of composite (Filtek Z250-3M ESPE) 4 mm high were built up and specimens were stored in deionized water for 24 hours at 37°C. Serial mesiodistal and buccolingual cuts were made and stick-like specimens were obtained, with transversal section of 1.0 mm(2). The samples were submitted to microtensile test at 1 mm/min and load of 10 kg in a universal testing machine. Data (MPa) were subjected to ANOVA and Tukey's tests (p < 0.05). Surface treatment with Diamond or CVD tips associated with Clearfil SE Bond adhesive produced significantly lower bond strength values compared to other groups. Surface treatment with Er: YAG laser associated with Single Bond Plus or Clearfil SE Bond adhesives and surface treatment with CVD tip associated with Adper Scotchbond SE adhesive produced significantly lower bond strength values compared to surface treatment with diamond or CVD tips associated with Single Bond Plus or Adper Scotchbond SE adhesives. Interactions between laser and the CVD tip technologies and the different adhesive systems can produce a satisfactory bonding strength result, so that these associations may be beneficial and enhance the clinical outcomes.

  8. The CRDS method application for study of the gas-phase processes in the hot CVD diamond thin film.

    NASA Astrophysics Data System (ADS)

    Buzaianumakarov, Vladimir; Hidalgo, Arturo; Morell, Gerardo; Weiner, Brad; Buzaianu, Madalina

    2006-03-01

    For detailed analysis of problem related to the hot CVD carbon-containing nano-material growing, we have to detect different intermediate species forming during the growing process as well as investigate dependences of concentrations of these species on different experimental parameters (concentrations of the CJH4, H2S stable chemical compounds and distance from the filament system to the substrate surface). In the present study, the HS and CS radicals were detected using the Cavity Ring Down Spectroscopic (CRDS) method in the hot CVD diamond thin film for the CH4(0.4 %) + H2 mixture doped by H2S (400 ppm). The absolute absorption density spectra of the HS and CS radicals were obtained as a function of different experimental parameters. This study proofs that the HS and CS radicals are an intermediate, which forms during the hot filament CVD process. The kinetics approach was developed for detailed analysis of the experimental data obtained. The kinetics scheme includes homogenous and heterogenous processes as well as processes of the chemical species transport in the CVD chamber.

  9. Is There a Dose-Response Relationship between Tea Consumption and All-Cause, CVD, and Cancer Mortality?

    PubMed

    Yan, Yi; Sui, Xuemei; Yao, Bin; Lavie, Carl J; Blair, Steven N

    2017-01-01

    A small change in tea consumption at population level could have large impact on public health. However, the health benefits of tea intake among Americans are inconclusive. To evaluate the association between tea consumption and all-causes, cardiovascular disease (CVD) and cancer mortality in the Aerobics Center Longitudinal study (ACLS). 11808 participants (20-82 years) initially free of CVD and cancers enrolled in the ACLS and were followed for mortality. Participants provided baseline self-report of tea consumption (cups/day). During a median follow-up of 16 years, 842 participants died. Of others, 250 died from CVD, and 345 died from cancer, respectively. A Cox proportional hazard model was used to produce hazard ratio (HR) and 95% confidence interval (CI). Compared with participants consuming no tea, tea drinkers had a survival advantage ( Log-2 = 10.2, df = 3, P = 0.017); however, the multivariate hazard ratios (HRs) of all-cause mortality for those drinking 1-7, 8-14, and >14 cups/week were 0.95 (95% CI, 0.81-1.12), 1.00 (95% CI, 0.82-1.22), and 0.98 (95% CI, 0.76-1.25), respectively (P for linear trend = 0.83). The multivariate HR were 1.16 (95% CI, 0.86-1.56), 1.22 (95% CI, 0.85-1.76), and 0.94 (95% CI, 0.56-1.54) for CVD mortality (P for linear trend = 0.47), and 0.97 (95% CI, 0.75-1.25), 0.85 (95% CI, 0.60-1.16), and 0.94 (95% CI, 0.64-1.38) for cancer mortality (P for trend = 0.62). There were week or null relationships between tea consumption and mortality due to all-cause, CVD disease or cancer were observed in ACLS.

  10. Spray CVD for Making Solar-Cell Absorber Layers

    NASA Technical Reports Server (NTRS)

    Banger, Kulbinder K.; Harris, Jerry; Jin, Michael H.; Hepp, Aloysius

    2007-01-01

    Spray chemical vapor deposition (spray CVD) processes of a special type have been investigated for use in making CuInS2 absorber layers of thin-film solar photovoltaic cells from either of two subclasses of precursor compounds: [(PBu3) 2Cu(SEt)2In(SEt)2] or [(PPh3)2Cu(SEt)2 In(SEt)2]. The CuInS2 films produced in the experiments have been characterized by x-ray diffraction, scanning electron microscopy, energy-dispersive spectroscopy, and four-point-probe electrical tests.

  11. Under-utilisation of preventive medication in patients with cardiovascular disease is greatest in younger age groups (PREDICT-CVD 15).

    PubMed

    Mehta, Suneela; Wells, Sue; Riddell, Tania; Kerr, Andrew; Pylypchuk, Romana; Marshall, Roger; Ameratunga, Shanthi; Chan, Wing Cheuk; Thornley, Simon; Crengle, Sue; Harrison, Jeff; Drury, Paul; Elley, C Raina; Bell, Fionna; Jackson, Rod

    2011-06-01

    Blood pressure-lowering (BPL) and lipid-lowering (LL) medications together reduce estimated absolute five-year cardiovascular disease (CVD) risk by >40%. International studies indicate that the proportion of people with CVD receiving pharmacotherapy increases with advancing age. To compare BPL and LL medications, by sociodemographic characteristics, for patients with known CVD in primary care settings. The study population included patients aged 35-74 with known CVD assessed in primary care from July 2006 to October 2009 using a web-based computerised decision support system (PREDICT) for risk assessment and management. Clinical data linked anonymously to national sociodemographic and pharmaceutical dispensing databases. Differences in dispensing BPL and LL medications in six months before first PREDICT assessment was analysed according to age, sex, ethnicity and deprivation. Of 7622 people with CVD, 1625 <55 years old, 2862 were women and 4609 lived in deprived areas (NZDep quintiles 4/5). The study population included 4249 European, 1556 Maori, 1151 Pacific and 329 Indian peoples. BPL medications were dispensed to 81%, LL medications to 73%, both BPL and LL medications to 67%, and 87% received either class of medication. Compared with people aged 65-75, people aged 35-44 were 30-40% less likely and those aged 45-54 were 10-15% less likely to be dispensed BPL, LL medications or both. There were minimal differences in likelihood of dispensing according to sex, ethnicity or deprivation. BPL and LL medications are under-utilised in patients with known CVD in New Zealand. Only two-thirds of patients in this cohort are on both. Younger patients are considerably less likely to be on recommended medications.

  12. Effect of growth temperature and precursor concentration on synthesis of CVD-graphene from camphor

    NASA Astrophysics Data System (ADS)

    Rajaram, Narasimman; Patel, Biren; Ray, Abhijit; Mukhopadhyay, Indrajit

    2018-05-01

    Here, we have synthesized CVD-graphene from camphor by using atmospheric pressure (AP)-CVD system on Cu foil. We have studied the effect of growth temperature and camphor concentration by using scanning electron microscopy (SEM) and Raman spectroscopy. The domain size of the graphene is increasing with an increase in the temperature and camphor quantity. The complete coverage of graphene on the Cu foil achieved at 1020 °C. Higher camphor quantity leads to growth of multilayer graphene. The graphene is transferred by PMMA-assisted method onto the glass substrate. The sheet resistance and transmittance of the graphene are 1.5 kohm/sq and 92.7%, respectively.

  13. Process in manufacturing high efficiency AlGaAs/GaAs solar cells by MO-CVD

    NASA Technical Reports Server (NTRS)

    Yeh, Y. C. M.; Chang, K. I.; Tandon, J.

    1984-01-01

    Manufacturing technology for mass producing high efficiency GaAs solar cells is discussed. A progress using a high throughput MO-CVD reactor to produce high efficiency GaAs solar cells is discussed. Thickness and doping concentration uniformity of metal oxide chemical vapor deposition (MO-CVD) GaAs and AlGaAs layer growth are discussed. In addition, new tooling designs are given which increase the throughput of solar cell processing. To date, 2cm x 2cm AlGaAs/GaAs solar cells with efficiency up to 16.5% were produced. In order to meet throughput goals for mass producing GaAs solar cells, a large MO-CVD system (Cambridge Instrument Model MR-200) with a susceptor which was initially capable of processing 20 wafers (up to 75 mm diameter) during a single growth run was installed. In the MR-200, the sequencing of the gases and the heating power are controlled by a microprocessor-based programmable control console. Hence, operator errors can be reduced, leading to a more reproducible production sequence.

  14. Large Area CVD MoS2 RF transistors with GHz performance

    NASA Astrophysics Data System (ADS)

    Nagavalli Yogeesh, Maruthi; Sanne, Atresh; Park, Saungeun; Akinwade, Deji; Banerjee, Sanjay

    Molybdenum disulfide (MoS2) is a 2D semiconductor in the family of transition metal dichalcogenides (TMDs). Its single layer direct bandgap of 1.8 eV allows for high ION/IOFF metal-oxide semiconducting field-effect transistors (FETs). More relevant for radio frequency (RF) wireless applications, theoretical studies predict MoS2 to have saturation velocities, vsat >3×106 cm/s. Facilitated by cm-scale CVD MoS2, here we design and fabricate both top-gated and embedded gate short channel MoS2 RF transistors, and provide a systematic comparison of channel length scaling, extrinsic doping from oxygen-deficient dielectrics, and a gate-first gate-last process flow. The intrinsic fT (fmax) obtained from the embedded gate transistors shows 3X (2X) improvement over top-gated CVD MoS2 RF FETs, and the largest high-field saturation velocity, vsat = 1.88 ×106 cm/s, in MoS2 reported so far. The gate-first approach, offers enhancement mode operation, ION/IOFF ratio of 10, 8< and the highest reported transconductance (gm) of 70 μS/ μm. By manipulating the interfacial oxygen vacancies in atomic layer deposited (ALD) HfO2-x we are able to achieve 2X current density over stoichiometric Al2O3. We demonstrate a common-source (CS) amplifier with voltage gain of 14 dB and an active frequency mixer with conversion gain of -15 dB. Our results of gigahertz frequency performance as well as analog circuit operation show that large area CVD MoS2 may be suitable for industrial-scale electronic applications.

  15. Spin transport studies in encapsulated CVD graphene

    NASA Astrophysics Data System (ADS)

    Avsar, Ahmet; You Tan, Jun; Ho, Yuda; Koon, Gavin; Oezyilmaz, Barbaros

    2013-03-01

    Spin transport studies in exfoliated graphene on SiO2/Si substrates have shown spin relaxation times that are orders of magnitude shorter than the theoretical predictions. Similar to the charge transport case, the underlying substrate is expected to be the limiting factor. The recent work Zomer, P. J. et al. shows that spin transport over lengths up to 20um is possible in high mobility exfoliated graphene devices on boron nitride (BN) substrates. Here we discuss our initial attempts to repeat such spin transport experiments with CVD graphene on BN substrates. The effect of encapsulation of such devices with an extra BN layer will be also discussed.

  16. Room Temperature Sensing Achieved by GaAs Nanowires and oCVD Polymer Coating.

    PubMed

    Wang, Xiaoxue; Ermez, Sema; Goktas, Hilal; Gradečak, Silvija; Gleason, Karen

    2017-06-01

    Novel structures comprised of GaAs nanowire arrays conformally coated with conducting polymers (poly(3,4-ethylenedioxythiophene) (PEDOT) or poly(3,4-ethylenedioxythiophene-co-3-thiophene acetic acid) display both sensitivity and selectivity to a variety of volatile organic chemicals. A key feature is room temperature operation, so that neither a heater nor the power it would consume, is required. It is a distinct difference from traditional metal oxide sensors, which typically require elevated operational temperature. The GaAs nanowires are prepared directly via self-seeded metal-organic chemical deposition, and conducting polymers are deposited on GaAs nanowires using oxidative chemical vapor deposition (oCVD). The range of thickness for the oCVD layer is between 100 and 200 nm, which is controlled by changing the deposition time. X-ray diffraction analysis indicates an edge-on alignment of the crystalline structure of the PEDOT coating layer on GaAs nanowires. In addition, the positive correlation between the improvement of sensitivity and the increasing nanowire density is demonstrated. Furthermore, the effect of different oCVD coating materials is studied. The sensing mechanism is also discussed with studies considering both nanowire density and polymer types. Overall, the novel structure exhibits good sensitivity and selectivity in gas sensing, and provides a promising platform for future sensor design. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. Projected Impact of a Sodium Consumption Reduction Initiative in Argentina: An Analysis from the CVD Policy Model – Argentina

    PubMed Central

    Konfino, Jonatan; Mekonnen, Tekeshe A.; Coxson, Pamela G.; Ferrante, Daniel; Bibbins-Domingo, Kirsten

    2013-01-01

    Background Cardiovascular disease (CVD) is the leading cause of death in adults in Argentina. Sodium reduction policies targeting processed foods were implemented in 2011 in Argentina, but the impact has not been evaluated. The aims of this study are to use Argentina-specific data on sodium excretion and project the impact of Argentina’s sodium reduction policies under two scenarios - the 2-year intervention currently being undertaken or a more persistent 10 year sodium reduction strategy. Methods We used Argentina-specific data on sodium excretion by sex and projected the impact of the current strategy on sodium consumption and blood pressure decrease. We assessed the projected impact of sodium reduction policies on CVD using the Cardiovascular Disease (CVD) Policy Model, adapted to Argentina, modeling two alternative policy scenarios over the next decade. Results Our study finds that the initiative to reduce sodium consumption currently in place in Argentina will have substantial impact on CVD over the next 10 years. Under the current proposed policy of 2-year sodium reduction, the mean sodium consumption is projected to decrease by 319–387 mg/day. This decrease is expected to translate into an absolute reduction of systolic blood pressure from 0.93 mmHg to 1.81 mmHg. This would avert about 19,000 all-cause mortality, 13,000 total myocardial infarctions, and 10,000 total strokes over the next decade. A more persistent sodium reduction strategy would yield even greater CVD benefits. Conclusion The impact of the Argentinean initiative would be effective in substantially reducing mortality and morbidity from CVD. This paper provides evidence-based support to continue implementing strategies to reduce sodium consumption at a population level. PMID:24040085

  18. Wafer-scalable high-performance CVD graphene devices and analog circuits

    NASA Astrophysics Data System (ADS)

    Tao, Li; Lee, Jongho; Li, Huifeng; Piner, Richard; Ruoff, Rodney; Akinwande, Deji

    2013-03-01

    Graphene field effect transistors (GFETs) will serve as an essential component for functional modules like amplifier and frequency doublers in analog circuits. The performance of these modules is directly related to the mobility of charge carriers in GFETs, which per this study has been greatly improved. Low-field electrostatic measurements show field mobility values up to 12k cm2/Vs at ambient conditions with our newly developed scalable CVD graphene. For both hole and electron transport, fabricated GFETs offer substantial amplification for small and large signals at quasi-static frequencies limited only by external capacitances at high-frequencies. GFETs biased at the peak transconductance point featured high small-signal gain with eventual output power compression similar to conventional transistor amplifiers. GFETs operating around the Dirac voltage afforded positive conversion gain for the first time, to our knowledge, in experimental graphene frequency doublers. This work suggests a realistic prospect for high performance linear and non-linear analog circuits based on the unique electron-hole symmetry and fast transport now accessible in wafer-scalable CVD graphene. *Support from NSF CAREER award (ECCS-1150034) and the W. M. Keck Foundation are appreicated.

  19. Associations between pre-diabetes, by three different diagnostic criteria, and incident CVD differ in South Asians and Europeans

    PubMed Central

    Eastwood, Sophie V; Tillin, Therese; Sattar, Naveed; Forouhi, Nita G; Hughes, Alun D; Chaturvedi, Nish

    2016-01-01

    Objective We examined longitudinal associations between pre-diabetes and cardiovascular disease (CVD) (coronary heart disease (CHD) and stroke) in Europeans and South Asians. Research design and methods UK cohort study of 1,336 Europeans and 1,139 South Asians, aged 40-69 years at baseline (1988-91). Assessment included blood pressure, blood tests, anthropometry and questionnaires. Pre-diabetes was determined by OGTT or HbA1c, using either International Expert Committee (IEC, HbA1c 6.0-6.5% (42-48 mmol/mol)) or American Diabetes Association (ADA, HbA1c 5.7-6.5% (39-48 mmol/mol)) cut-points. Incident CHD and stroke were established at 20 years from death certification, hospital admission, primary care record review and participant report. Results Compared to normoglycaemic individuals, IEC-defined pre-diabetes was related to both CHD and CVD risk in Europeans but not South Asians (sub-hazards ratio[95% CI]: CHD;1.68[1.19,2.37] vs. 0.99[0.74,1.33], ethnicity interaction p=0.008, CVD; 1.49[1.08,2.07] vs. 1.03[0.79,1.36], ethnicity interaction p=0.04). Conversely, IEC-defined pre-diabetes was associated with stroke risk in South Asians but not Europeans (1.75 [1.04,2.93] vs. 0.85[0.45,1.64], ethnicity interaction p=0.11). Risks were adjusted for age, sex, smoking, total/HDL-cholesterol ratio, waist/hip ratio, systolic blood pressure and anti-hypertensive use. . Associations were weaker for OGTT or ADA-defined pre-diabetes. Conversion from pre-diabetes to diabetes was greater in South Asians, but accounting for time to conversion did not account for these ethnic differences. Conclusions Associations between pre-diabetes and CVD differed by pre-diabetes diagnostic criterion, type of CVD and ethnicity, with associations being present for overall CVD in Europeans but not South Asians. Substantiation of these findings and investigation of potential explanations are required. PMID:26486189

  20. Material removal characteristics of orthogonal velocity polishing tool for efficient fabrication of CVD SiC mirror surfaces

    NASA Astrophysics Data System (ADS)

    Seo, Hyunju; Han, Jeong-Yeol; Kim, Sug-Whan; Seong, Sehyun; Yoon, Siyoung; Lee, Kyungmook; Lee, Haengbok

    2015-09-01

    Today, CVD SiC mirrors are readily available in the market. However, it is well known to the community that the key surface fabrication processes and, in particular, the material removal characteristics of the CVD SiC mirror surface varies sensitively depending on the shop floor polishing and figuring variables. We investigated the material removal characteristics of CVD SiC mirror surfaces using a new and patented polishing tool called orthogonal velocity tool (OVT) that employs two orthogonal velocity fields generated simultaneously during polishing and figuring machine runs. We built an in-house OVT machine and its operating principle allows for generation of pseudo Gaussian shapes of material removal from the target surface. The shapes are very similar to the tool influence functions (TIFs) of other polishing machine such as IRP series polishing machines from Zeeko. Using two CVD SiC mirrors of 150 mm in diameter and flat surface, we ran trial material removal experiments over the machine run parameter ranges from 12.901 to 25.867 psi in pressure, 0.086 m/sec to 0.147 m/sec in tool linear velocity, and 5 to 15 sec in dwell time. An in-house developed data analysis program was used to obtain a number of Gaussian shaped TIFs and the resulting material removal coefficient varies from 3.35 to 9.46 um/psi hour m/sec with the mean value to 5.90 ± 1.26(standard deviation). We report the technical details of the new OVT machine, of the data analysis program, of the experiments and the results together with the implications to the future development of the OVT machine and process for large CVD SiC mirror surfaces.

  1. Circulating and dietary omega-3 and omega-6 polyunsaturated fatty acids and incidence of CVD in the Multi-Ethnic Study of Atherosclerosis.

    PubMed

    de Oliveira Otto, Marcia C; Wu, Jason H Y; Baylin, Ana; Vaidya, Dhananjay; Rich, Stephen S; Tsai, Michael Y; Jacobs, David R; Mozaffarian, Dariush

    2013-12-18

    Dietary guidelines support intake of polyunsaturated fatty acids (PUFAs) in fish and vegetable oils. However, some controversy remains about benefits of PUFAs, and most prior studies have relied on self-reported dietary assessment in relatively homogeneous populations. In a multiethnic cohort of 2837 US adults (whites, Hispanics, African Americans, Chinese Americans), plasma phospholipid PUFAs were measured at baseline (2000-2002) using gas chromatography and dietary PUFAs estimated using a food frequency questionnaire. Incident cardiovascular disease (CVD) events (including coronary heart disease and stroke; n=189) were prospectively identified through 2010 during 19 778 person-years of follow-up. In multivariable-adjusted Cox models, circulating n-3 eicosapentaenoic acid and docosahexaenoic acid were inversely associated with incident CVD, with extreme-quartile hazard ratios (95% CIs) of 0.49 for eicosapentaenoic acid (0.30 to 0.79; Ptrend=0.01) and 0.39 for docosahexaenoic acid (0.22 to 0.67; Ptrend<0.001). n-3 Docosapentaenoic acid (DPA) was inversely associated with CVD in whites and Chinese, but not in other race/ethnicities (P-interaction=0.01). No significant associations with CVD were observed for circulating n-3 alpha-linolenic acid or n-6 PUFA (linoleic acid, arachidonic acid). Associations with CVD of self-reported dietary PUFA were consistent with those of the PUFA biomarkers. All associations were similar across racial-ethnic groups, except those of docosapentaenoic acid. Both dietary and circulating eicosapentaenoic acid and docosahexaenoic acid, but not alpha-linolenic acid or n-6 PUFA, were inversely associated with CVD incidence. These findings suggest that increased consumption of n-3 PUFA from seafood may prevent CVD development in a multiethnic population.

  2. Coffee consumption is not associated with prevalent subclinical cardiovascular disease (CVD) or the risk of CVD events, in nonalcoholic fatty liver disease: Results from the multi-ethnic study of atherosclerosis

    USDA-ARS?s Scientific Manuscript database

    Atherosclerosis and its clinical sequelae represent the leading cause of mortality among patients with nonalcoholic fatty liver disease (NAFLD). While epidemiologic data support the hepatoprotective benefits of coffee in NAFLD, whether coffee improves NAFLD-associated Cardiovascular Disease (CVD) ri...

  3. Use of microcirculatory parameters to evaluate clinical treatments of chronic venous disorder (CVD).

    PubMed

    Lascasas-Porto, Carmen Lucia; Milhomens, Ana Letícia M; Virgini-Magalhães, Carlos Eduardo; Fernandes, Fabiano F A; Sicuro, Fernando L; Bouskela, Eliete

    2008-05-01

    To evaluate changes on cutaneous microangiopathy in chronic venous disorder (CVD) after use of Cirkan [venotonic drug containing Ruscus aculeatus (plant extract), hesperidine methylchalcone (flavonoid) and vitamin C], elastic compression stockings (ECS) or no treatment for four weeks. Fifty-five female patients (85 legs), 25 to 57 years, with at least one limb classified as C2,s or C2,3,s (CEAP classification), were allocated consecutively, according to entrance order, in these three groups. Ten healthy women age-matched were also investigated. Using orthogonal polarization spectral technique (noninvasive method), measurements of functional capillary density (FCD, number of capillaries with flowing red blood cells/mm(2)), capillary morphology (CM, % of abnormal capillaries/mm(2)) and diameters (mum) of dermal papilla (DDP), capillary bulk (DCB) and capillary limb (CD) were obtained on the medial perimalleolar region and later analyzed using CapImage software. CVD patients showed significant changes on CD and CM compared to healthy subjects in agreement with our previous findings (J Vasc Surg 43:1037-1044, 2006). On Cirkan-treated patients, after 4 weeks, CD decreased on both limbs and CM improved on the left one, suggesting an amelioration of the chronic venous hypertension. No significant changes could be detected on other patient groups. These results confirm the existence of microcirculatory dysfunction in early stages of CVD, probably due to post-capillary hypertension, and further support the venotonic action of Cirkan.

  4. Nitrogen and silicon defect incorporation during homoepitaxial CVD diamond growth on (111) surfaces

    DOE PAGES

    Moore, Samuel L.; Vohra, Yogesh K.

    2015-01-01

    Chemical Vapor Deposited (CVD) diamond growth on (111)-diamond surfaces has received increased attention lately because of the use of N-V related centers in quantum computing as well as application of these defect centers in sensing nano-Tesla strength magnetic fields. We have carried out a detailed study of homoepitaxial diamond deposition on (111)-single crystal diamond (SCD) surfaces using a 1.2 kW microwave plasma CVD (MPCVD) system employing methane/hydrogen/nitrogen/oxygen gas phase chemistry. We have utilized Type Ib (111)-oriented single crystal diamonds as seed crystals in our study. The homoepitaxially grown diamond films were analyzed by Raman spectroscopy, Photoluminescence Spectroscopy (PL), X-ray Photoelectronmore » Spectroscopy (XPS), Scanning Electron Microscopy (SEM) and Atomic Force Microscopy (AFM). The nitrogen concentration in the plasma was carefully varied between 0 and 1500 ppm while a ppm level of silicon impurity is present in the plasma from the quartz bell jar. The concentration of N-V defect centers with PL zero phonon lines (ZPL) at 575nm and 637nm and the Si-defect center with a ZPL at 737nm were experimentally detected from a variation in CVD growth conditions and were quantitatively studied. As a result, altering nitrogen and oxygen concentration in the plasma was observed to directly affect N-V and Si-defect incorporation into the (111)-oriented diamond lattice and these findings are presented.« less

  5. Revealing the microscopic CVD growth mechanism of MoSe2 and the role of hydrogen gas during the growth procedure.

    PubMed

    Wang, Hulian; Zhu, Dancheng; Jiang, Feng; Zhao, Pei; Wang, Hongtao; Zhang, Ze; Chen, Xin; Jin, Chuanhong

    2018-08-03

    Understanding the microscopic mechanisms for the nucleation and growth of two-dimensional molybdenum diselenide (2D MoSe 2 ) via chemical vapor deposition (CVD) is crucial towards the precisely controlled growth of the 2D material. In this work, we employed a joint use of transmission electron microscopy and CVD, in which the 2D MoSe 2 were directly grown on a graphene membrane based on grids, that enables the microstructural characterization of as-grown MoSe 2 flakes. We further explore the role of hydrogen gas and find: in an argon ambient, the primary products are few-layer MoSe 2 flakes, along with MoO x nanoparticles; while with the introduction of H 2 , single-layer MoSe 2 became the dominant product during the CVD growth. Quantitative analysis of the effects of H 2 flow rate on the flake sizes, and areal coverage was also given. Nevertheless, we further illuminated the evolution of shape morphology and edge structures of single-layer MoSe 2 , and proposed the associated growth routes during a typical CVD process.

  6. Dietary fried fish intake increases risk of CVD: the REasons for Geographic And Racial Differences in Stroke (REGARDS) study.

    PubMed

    Nahab, Fadi; Pearson, Keith; Frankel, Michael R; Ard, Jamy; Safford, Monika M; Kleindorfer, Dawn; Howard, Virginia J; Judd, Suzanne

    2016-12-01

    The objective of the present study was to examine the relationship of dietary fried fish consumption and risk of cardiovascular events and all-cause mortality. Prospective cohort study among participants of the REasons for Geographic And Racial Differences in Stroke (REGARDS) study who resided in the USA. The primary outcome measures included the hazard ratios (HR) of incident CVD including first incident fatal or non-fatal ischaemic stroke or myocardial infarction and all-cause mortality, based on cumulative average fish consumption ascertained at baseline. Participants (n 16 479) were enrolled between 2003 and 2007, completed the self-administered Block98 FFQ and were free of CVD at baseline. There were 700 cardiovascular events over a mean follow-up of 5·1 years. After adjustment for sociodemographic variables, health behaviours and other CVD risk factors, participants eating ≥2 servings fried fish/week (v. <1 serving/month) were at a significantly increased risk of cardiovascular events (HR=1·63; 95 % CI 1·11, 2·40). Intake of non-fried fish was not associated with risk of incident CVD. There was no association found with dietary fried or non-fried fish intake and cardiovascular or all-cause mortality. Fried fish intake of two or more servings per week is associated with an increased risk of cardiovascular events. Given the increased intake of fried fish in the stroke belt and among African Americans, these data suggest that dietary fried fish intake may contribute to geographic and racial disparities in CVD.

  7. Acetylene-sourced CVD-synthesised catalytically active graphene for electrochemical biosensing.

    PubMed

    Osikoya, Adeniyi Olugbenga; Parlak, Onur; Murugan, N Arul; Dikio, Ezekiel Dixon; Moloto, Harry; Uzun, Lokman; Turner, Anthony Pf; Tiwari, Ashutosh

    2017-03-15

    In this study, we have demonstrated the use of chemical vapour deposition (CVD) grown-graphene to develop a highly-ordered graphene-enzyme electrode for electrochemical biosensing. The graphene sheets were deposited on 1.00mm thick copper sheet at 850°C using acetylene (C 2 H 2 ) as carbon source in an argon (Ar) and nitrogen (N 2 ) atmosphere. An anionic surfactant was used to increase wettability and hydrophilicity of graphene; thereby facilitating the assembly of biomolecules on the electrode surface. Meanwhile, the theoretical calculations confirmed the successful modification of hydrophobic nature of graphene through the anionic surface assembly, which allowed high-ordered immobilisation of glucose oxidase (GOx) on the graphene. The electrochemical sensing activities of the graphene-electrode was explored as a model for bioelectrocatalysis. The bioelectrode exhibited a linear response to glucose concentration ranging from 0.2 to 9.8mM, with sensitivity of 0.087µA/µM/cm 2 and a detection limit of 0.12µM (S/N=3). This work sets the stage for the use of acetylene-sourced CVD-grown graphene as a fundamental building block in the fabrication of electrochemical biosensors and other bioelectronic devices. Copyright © 2016 Elsevier B.V. All rights reserved.

  8. The Oxidation of CVD Silicon Carbide in Carbon Dioxide

    NASA Technical Reports Server (NTRS)

    Opila, Elizabeth J.; Nguyen, QuynchGiao N.

    1997-01-01

    Chemically-vapor-deposited silicon carbide (CVD SiC) was oxidized in carbon dioxide (CO2) at temperatures of 1200-1400 C for times between 100 and 500 hours at several gas flow rates. Oxidation weight gains were monitored by thermogravimetric analysis (TGA) and were found to be very small and independent of temperature. Possible rate limiting kinetic laws are discussed. Oxidation of SiC by CO2 is negligible compared to the rates measured for other oxidants typically found in combustion environments: oxygen and water vapor.

  9. A comparative analysis of cardiovascular disease risk profiles of five Pacific ethnic groups assessed in New Zealand primary care practice: PREDICT CVD-13.

    PubMed

    Grey, Corina; Wells, Sue; Riddell, Tania; Pylypchuk, Romana; Marshall, Roger; Drury, Paul; Elley, Raina; Ameratunga, Shanthi; Gentles, Dudley; Erick-Peletiy, Stephanie; Bell, Fionna; Kerr, Andrew; Jackson, Rod

    2010-11-05

    Data on the cardiovascular disease risk profiles of Pacific peoples in New Zealand is usually aggregated and treated as a single entity. Little is known about the comparability or otherwise of cardiovascular disease (CVD) risk between different Pacific groups. To compare CVD risk profiles for the main Pacific ethnic groups assessed in New Zealand primary care practice to determine if it is reasonable to aggregate these data, or if significant differences exist. A web-based clinical decision support system for CVD risk assessment and management (PREDICT) has been implemented in primary care practices in nine PHOs throughout Auckland and Northland since 2002, covering approximately 65% of the population of these regions. Between 2002 and January 2009, baseline CVD risk assessments were carried out on 11,642 patients aged 35-74 years identifying with one or more Pacific ethnic groups (4933 Samoans, 1724 Tongans, 1366 Cook Island Maori, 880 Niueans, 1341 Fijians and 1398 people identified as Other Pacific or Pacific Not Further Defined). Fijians were subsequently excluded from the analyses because of a probable misclassification error that appears to combine Fijian Indians with ethnic Fijians. Prevalences of smoking, diabetes and prior history of CVD, as well as mean total cholesterol/HDL ratio, systolic and diastolic blood pressures, and Framingham 5-year CVD risk were calculated for each Pacific group. Age-adjusted risk ratios and mean differences stratified by gender were calculated using Samoans as the reference group. Cook Island women were almost 60% more likely to smoke than Samoan women. While Tongan men had the highest proportion of smoking (29%) among Pacific men, Tongan women had the lowest smoking proportion (10%) among Pacific women. Tongan women and Niuean men and women had a higher burden of diabetes than other Pacific ethnic groups, which were 20-30% higher than their Samoan counterparts. Niuean men and women had lower blood pressure levels than all

  10. Growth of InAs NWs with controlled morphology by CVD

    NASA Astrophysics Data System (ADS)

    Huang, Y. S.; Li, M.; Wang, J.; Xing, Y.; Xu, H. Q.

    2017-06-01

    We report on the growth of single crystal InAs NWs on Si/SiOx substrates by chemical vapor deposition (CVD). By adjusting growth parameters, the diameters, morphology, length and the proportion of superlattice ZB InAs NWs (NWs) can be controlled on a Si/SiOx substrate. Our work provides a low-cost route to grow and phase-engineer single crystal InAs NWs for a wide range of potential applications.

  11. Parameterisation of radiation effects on CVD diamond for proton irradiation

    NASA Astrophysics Data System (ADS)

    Hartjes, F.; Adam, W.; Bauer, C.; Berdermann, E.; Bergonzo, P.; Bogani, F.; Borchi, E.; Brambilla, A.; Bruzzi, M.; Colledani, C.; Conway, J.; Dabrowski, W.; Delpierre, P.; Deneuville, A.; Dulinski, W.; van Eijk, B.; Fallou, A.; Fizzotti, F.; Foulon, F.; Friedl, M.; Gan, K. K.; Gheeraert, E.; Grigoriev, E.; Hallewell, G.; Hall-Wilton, R.; Han, S.; Hrubec, J.; Husson, D.; Kagan, H.; Kania, D.; Kaplon, J.; Karl, C.; Kass, R.; Knöpfle, K. T.; Krammer, M.; Logiudice, A.; Lu, R.; Manfredi, P. F.; Manfredotti, C.; Marshall, R. D.; Meier, D.; Mishina, M.; Oh, A.; Pan, L. S.; Palmieri, V. G.; Pernicka, M.; Peitz, A.; Pirollo, S.; Polesello, P.; Pretzl, K.; Procario, M.; Re, V.; Riester, J. L.; Roe, S.; Roff, D.; Rudge, A.; Runolfsson, O.; Russ, J.; Schnetzer, S.; Sciortino, S.; Speziali, V.; Stelzer, H.; Stone, R.; Suter, B.; Tapper, R. J.; Tesarek, R.; Trawick, M.; Trischuk, W.; Vittone, E.; Wagner, A.; Walsh, A. M.; Wedenig, R.; Weilhammer, P.; White, C.; Zeuner, W.; Ziock, H.; Zoeller, M.; RD42 Collaboration

    1999-08-01

    The paper reviews measurements of the radiation hardness of CVD diamond for 24 GeV/c proton irradiation at fluences up to 5 ∗10 15 protons/cm 2. The results not only show radiation damage but also an annealing effect that is dominant at levels around 10 15 protons/cm 2. A model describing both effects is introduced, enabling a prediction of the distribution curve of the charge signal for other levels.

  12. The impact of a point-of-care testing device on CVD risk assessment completion in New Zealand primary-care practice: A cluster randomised controlled trial and qualitative investigation.

    PubMed

    Wells, Sue; Rafter, Natasha; Kenealy, Timothy; Herd, Geoff; Eggleton, Kyle; Lightfoot, Rose; Arcus, Kim; Wadham, Angela; Jiang, Yannan; Bullen, Chris

    2017-01-01

    To assess the effect of a point of care (POC) device for testing lipids and HbA1c in addition to testing by community laboratory facilities (usual practice) on the completion of cardiovascular disease (CVD) risk assessments in general practice. We conducted a pragmatic, cluster randomised controlled trial in 20 New Zealand general practices stratified by size and rurality and randomised to POC device plus usual practice or usual practice alone (controls). Patients aged 35-79 years were eligible if they met national guideline criteria for CVD risk assessment. Data on CVD risk assessments were aggregated using a web-based decision support programme common to each practice. Data entered into the on-line CVD risk assessment form could be saved pending blood test results. The primary outcome was the proportion of completed CVD risk assessments. Qualitative data on practice processes for CVD risk assessment and feasibility of POC testing were collected at the end of the study by interviews and questionnaire. The POC testing was supported by a comprehensive quality assurance programme. A CVD risk assessment entry was recorded for 7421 patients in 10 POC practices and 6217 patients in 10 control practices; 99.5% of CVD risk assessments had complete data in both groups (adjusted odds ratio 1.02 [95%CI 0.61-1.69]). There were major external influences that affected the trial: including a national performance target for CVD risk assessment and changes to CVD guidelines. All practices had invested in systems and dedicated staff time to identify and follow up patients to completion. However, the POC device was viewed by most as an additional tool rather than as an opportunity to review practice work flow and leverage the immediate test results for patient education and CVD risk management discussions. Shortly after commencement, the trial was halted due to a change in the HbA1c test assay performance. The trial restarted after the manufacturing issue was rectified but this

  13. CVD-diamond-based position sensitive photoconductive detector for high-flux x-rays and gamma rays.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shu, D.

    1999-04-19

    A position-sensitive photoconductive detector (PSPCD) using insulating-type CVD diamond as its substrate material has been developed at the Advanced Photon Source (APS). Several different configurations, including a quadrant pattern for a x-ray-transmitting beam position monitor (TBPM) and 1-D and 2-D arrays for PSPCD beam profilers, have been developed. Tests on different PSPCD devices with high-heat-flux undulator white x-ray beam, as well as with gamma-ray beams from {sup 60}Co sources have been done at the APS and National Institute of Standards and Technology (NIST). It was proven that the insulating-type CVD diamond can be used to make a hard x-ray andmore » gamma-ray position-sensitive detector that acts as a solid-state ion chamber. These detectors are based on the photoconductivity principle. A total of eleven of these TBPMs have been installed on the APS front ends for commissioning use. The linear array PSPCD beam profiler has been routinely used for direct measurements of the undulator white beam profile. More tests with hard x-rays and gamma rays are planned for the CVD-diamond 2-D imaging PSPCD. Potential applications include a high-dose-rate beam profiler for fourth-generation synchrotrons radiation facilities, such as free-electron lasers.« less

  14. CVD diamond detectors for ionizing radiation

    NASA Astrophysics Data System (ADS)

    Friedl, M.; Adam, W.; Bauer, C.; Berdermann, E.; Bergonzo, P.; Bogani, F.; Borchi, E.; Brambilla, A.; Bruzzi, M.; Colledani, C.; Conway, J.; Dabrowski, W.; Delpierre, P.; Deneuville, A.; Dulinski, W.; van Eijk, B.; Fallou, A.; Fizzotti, F.; Foulon, F.; Gan, K. K.; Gheeraert, E.; Grigoriev, E.; Hallewell, G.; Hall-Wilton, R.; Han, S.; Hartjes, F.; Hrubec, J.; Husson, D.; Kagan, H.; Kania, D.; Kaplon, J.; Karl, C.; Kass, R.; Knöpfle, K. T.; Krammer, M.; Logiudice, A.; Lu, R.; Manfredi, P. F.; Manfredotti, C.; Marshall, R. D.; Meier, D.; Mishina, M.; Oh, A.; Pan, L. S.; Palmieri, V. G.; Pernegger, H.; Pernicka, M.; Peitz, A.; Pirollo, S.; Polesello, P.; Pretzl, K.; Re, V.; Riester, J. L.; Roe, S.; Roff, D.; Rudge, A.; Schnetzer, S.; Sciortino, S.; Speziali, V.; Stelzer, H.; Stone, R.; Tapper, R. J.; Tesarek, R.; Thomson, G. B.; Trawick, M.; Trischuk, W.; Vittone, E.; Walsh, A. M.; Wedenig, R.; Weilhammer, P.; Ziock, H.; Zoeller, M.; RD42 Collaboration

    1999-10-01

    In future HEP accelerators, such as the LHC (CERN), detectors and electronics in the vertex region of the experiments will suffer from extreme radiation. Thus radiation hardness is required for both detectors and electronics to survive in this harsh environment. CVD diamond, which is investigated by the RD42 Collaboration at CERN, can meet these requirements. Samples of up to 2×4 cm2 have been grown and refined for better charge collection properties, which are measured with a β source or in a testbeam. A large number of diamond samples has been irradiated with hadrons to fluences of up to 5×10 15 cm-2 to study the effects of radiation. Both strip and pixel detectors were prepared in various geometries. Samples with strip metallization have been tested with both slow and fast readout electronics, and the first diamond pixel detector proved fully functional with LHC electronics.

  15. Significance of vapor phase chemical reactions on CVD rates predicted by chemically frozen and local thermochemical equilibrium boundary layer theories

    NASA Technical Reports Server (NTRS)

    Gokoglu, Suleyman A.

    1988-01-01

    This paper investigates the role played by vapor-phase chemical reactions on CVD rates by comparing the results of two extreme theories developed to predict CVD mass transport rates in the absence of interfacial kinetic barrier: one based on chemically frozen boundary layer and the other based on local thermochemical equilibrium. Both theories consider laminar convective-diffusion boundary layers at high Reynolds numbers and include thermal (Soret) diffusion and variable property effects. As an example, Na2SO4 deposition was studied. It was found that gas phase reactions have no important role on Na2SO4 deposition rates and on the predictions of the theories. The implications of the predictions of the two theories to other CVD systems are discussed.

  16. Paralinear Oxidation of CVD SiC in Water Vapor

    NASA Technical Reports Server (NTRS)

    Opila, Elizabeth J.; Hann, Raiford E., Jr.

    1997-01-01

    The oxidation kinetics of CVD SiC were monitored by thermogravimetric analysis (TGA) in a 50% H2O/50% O2 gas mixture flowing at 4.4 cm/s for temperatures between 1200 and 1400 C. Paralinear weight change kinetics were observed as the water vapor oxidized the SiC and simultaneously volatilized the silica scale. The long-term degradation rate of SiC is determined by the volatility of the silica scale. Rapid SiC surface recession rates were estimated from these data for actual aircraft engine combustor conditions.

  17. The integration of epigenetics and genetics in nutrition research for CVD risk factors

    USDA-ARS?s Scientific Manuscript database

    There is increasing evidence documenting gene-by-environment (G x E) interactions for CVD related traits. However, the underlying mechanisms are still unclear. DNA methylation may represent one of such potential mechanisms. The objective of this review paper is to summarise the current evidence supp...

  18. Ultratough CVD single crystal diamond and three dimensional growth thereof

    DOEpatents

    Hemley, Russell J [Washington, DC; Mao, Ho-kwang [Washington, DC; Yan, Chih-shiue [Washington, DC

    2009-09-29

    The invention relates to a single-crystal diamond grown by microwave plasma chemical vapor deposition that has a toughness of at least about 30 MPa m.sup.1/2. The invention also relates to a method of producing a single-crystal diamond with a toughness of at least about 30 MPa m.sup.1/2. The invention further relates to a process for producing a single crystal CVD diamond in three dimensions on a single crystal diamond substrate.

  19. Zero end-digit preference in recorded blood pressure and its impact on classification of patients for pharmacologic management in primary care - PREDICT-CVD-6.

    PubMed

    Broad, Joanna; Wells, Sue; Marshall, Roger; Jackson, Rod

    2007-11-01

    Most blood pressure recordings end with a zero end-digit despite guidelines recommending measurement to the nearest 2 mmHg. The impact of rounding on management of cardiovascular disease (CVD) risk is unknown. To document the use of rounding to zero end-digit and assess its potential impact on eligibility for pharmacologic management of CVD risk. Cross-sectional study. A total of 23,676 patients having opportunistic CVD risk assessment in primary care practices in New Zealand. To simulate rounding in practice, for patients with systolic blood pressures recorded without a zero end-digit, a second blood pressure measure was generated by arithmetically rounding to the nearest zero end-digit. A 10-year Framingham CVD risk score was estimated using actual and rounded blood pressures. Eligibility for pharmacologic treatment was then determined using the Joint British Societies' JBS2 and the British Hypertension Society BHS-IV guidelines based on actual and rounded blood pressure values. Zero end-digits were recorded in 64% of systolic and 62% of diastolic blood pressures. When eligibility for drug treatment was based only on a Framingham 10year CVD risk threshold of 20% or more, rounding misclassified one in 41 of all those patients subject to this error. Under the two guidelines which use different combinations of CVD risk and blood pressure thresholds, one in 19 would be misclassified under JBS2 and one in 12 under the BHS-IV guidelines mostly towards increased treatment. Zero end-digit preference significantly increases a patient's likelihood of being classified as eligible for drug treatment. Guidelines that base treatment decisions primarily on absolute CVD risk are less susceptible to these errors.

  20. Heparin free coating on PLA membranes for enhanced hemocompatibility via iCVD

    NASA Astrophysics Data System (ADS)

    Wang, Hui; Shi, Xiao; Gao, Ailin; Lin, Haibo; Chen, Yongliang; Ye, Yumin; He, Jidong; Liu, Fu; Deng, Gang

    2018-03-01

    In the present work, we report one-step immobilization of nano-heparin coating on PLA membranes via initiated chemical vapor deposition (iCVD) for enhanced hemocompatibility. The nano-coating introduced onto the membrane surface via the crosslinking of P(MAA-EGDA) was confirmed by the FTIR, SEM and weight measurement respectively. The negative carboxyl groups could form the hydration interaction with the protein and platelets and electrostatic interaction with amide groups of thrombin by the mediation of antithrombin, which is similar but different with heparin. The P(MAA-EGDA) coated membranes showed suppressed platelet adhesion and prolonged clotting time (APTTs increased to 59 s, PTs increased to 20.4 s, TTs increased to 17.5 s, and the FIBs declined by 30 mg/dL). Moreover, the complement activation tests demonstrated the formation of C3a and C5a was inhibited. All results demonstrated that the nano-coating of P(MAA-EGDA) via iCVD significantly enhanced the hemocompatibility of PLA membranes, which is also applicable for various membranes.

  1. Survival Regression Modeling Strategies in CVD Prediction.

    PubMed

    Barkhordari, Mahnaz; Padyab, Mojgan; Sardarinia, Mahsa; Hadaegh, Farzad; Azizi, Fereidoun; Bozorgmanesh, Mohammadreza

    2016-04-01

    A fundamental part of prevention is prediction. Potential predictors are the sine qua non of prediction models. However, whether incorporating novel predictors to prediction models could be directly translated to added predictive value remains an area of dispute. The difference between the predictive power of a predictive model with (enhanced model) and without (baseline model) a certain predictor is generally regarded as an indicator of the predictive value added by that predictor. Indices such as discrimination and calibration have long been used in this regard. Recently, the use of added predictive value has been suggested while comparing the predictive performances of the predictive models with and without novel biomarkers. User-friendly statistical software capable of implementing novel statistical procedures is conspicuously lacking. This shortcoming has restricted implementation of such novel model assessment methods. We aimed to construct Stata commands to help researchers obtain the aforementioned statistical indices. We have written Stata commands that are intended to help researchers obtain the following. 1, Nam-D'Agostino X 2 goodness of fit test; 2, Cut point-free and cut point-based net reclassification improvement index (NRI), relative absolute integrated discriminatory improvement index (IDI), and survival-based regression analyses. We applied the commands to real data on women participating in the Tehran lipid and glucose study (TLGS) to examine if information relating to a family history of premature cardiovascular disease (CVD), waist circumference, and fasting plasma glucose can improve predictive performance of Framingham's general CVD risk algorithm. The command is adpredsurv for survival models. Herein we have described the Stata package "adpredsurv" for calculation of the Nam-D'Agostino X 2 goodness of fit test as well as cut point-free and cut point-based NRI, relative and absolute IDI, and survival-based regression analyses. We hope this

  2. Premature menopause linked to CVD and osteoporosis.

    PubMed

    Park, Claire; Overton, Caroline

    2010-03-01

    Premature menopause affects 1% of women under the age of 40, the usual age of the menopause is 51. Most women will present with irregular periods or no periods at all with or without climacteric symptoms. Around 10% of women present with primary amenorrhoea. A careful history and examination are required. It is important to ask specifically about previous chemotherapy or radiotherapy and to look for signs of androgen excess e.g. polycystic ovarian syndrome, adrenal problems e.g. galactorrhoea and thyroid goitres. Once pregnancy has been excluded, a progestagen challenge test can be performed in primary care. Norethisterone 5 mg tds po for ten days or alternatively medroxyprogesterone acetate 10 mg daily for ten days is prescribed. A withdrawal bleed within a few days of stopping the norethisterone indicates the presence of oestrogen and bleeding more than a few drops is considered a positive withdrawal bleed. The absence of a bleed indicates low levels of oestrogen, putting the woman at risk of CVD and osteoporosis. FSH levels above 30 IU/l are an indicator that the ovaries are failing and the menopause is approaching or has occurred. It should be remembered that FSH levels fluctuate during the month and from one month to the next, so a minimum of two measurements should be made at least four to six weeks apart. The presence of a bleed should not exclude premature menopause as part of the differential diagnosis as there can be varying and unpredictable ovarian function remaining. The progestagen challenge test should not be used alone, but in conjunction with FSH, LH and oestradiol. There is no treatment for premature menopause. Women desiring pregnancy should be referred to a fertility clinic and discussion of egg donation. Women not wishing to become pregnant should be prescribed HRT until the age of 50 to control symptoms of oestrogen deficiency and reduce the risks of osteoporosis and CVD.

  3. Enhanced B doping in CVD-grown GeSn:B using B δ-doping layers

    NASA Astrophysics Data System (ADS)

    Kohen, David; Vohra, Anurag; Loo, Roger; Vandervorst, Wilfried; Bhargava, Nupur; Margetis, Joe; Tolle, John

    2018-02-01

    Highly doped GeSn material is interesting for both electronic and optical applications. GeSn:B is a candidate for source-drain material in future Ge pMOS device because Sn adds compressive strain with respect to pure Ge, and therefore can boost the Ge channel performances. A high B concentration is required to obtain low contact resistivity between the source-drain material and the metal contact. To achieve high performance, it is therefore highly desirable to maximize both the Sn content and the B concentration. However, it has been shown than CVD-grown GeSn:B shows a trade-off between the Sn incorporation and the B concentration (increasing B doping reduces Sn incorporation). Furthermore, the highest B concentration of CVD-grown GeSn:B process reported in the literature has been limited to below 1 × 1020 cm-3. Here, we demonstrate a CVD process where B δ-doping layers are inserted in the GeSn layer. We studied the influence of the thickness between each δ-doping layers and the δ-doping layers process conditions on the crystalline quality and the doping density of the GeSn:B layers. For the same Sn content, the δ-doping process results in a 4-times higher B doping than the co-flow process. In addition, a B doping concentration of 2 × 1021 cm-3 with an active concentration of 5 × 1020 cm-3 is achieved.

  4. Freedom poverty: a new tool to identify the multiple disadvantages affecting those with CVD.

    PubMed

    Callander, Emily J; Schofield, Deborah J; Shrestha, Rupendra N

    2013-06-20

    It is recognised that CVD affects an individual's financial situation, placing them in income poverty. However, recent developments in poverty measurement practice recognises other forms of disadvantage other than low income, such as poor health and insufficient education also affect living standards. Using the Freedom Poverty Measure, the multiple forms of disadvantage experienced by those with no health condition, heart disease, other diseases of the circulatory system, and all other health conditions was assessed using data on the adult Australian population contained in the 2003 Survey of Disability, Ageing and Carers. 24% of those with heart disease and 23% of those with other diseases of the circulatory system were in freedom poverty, suffering from multiple forms of disadvantage. Those with heart disease and those with other diseases of the circulatory system were around three times more likely to be in freedom poverty (OR 3.02, 95% CI: 2.29-3.99, p<.0001; OR 2.78, 95% CI: 1.94-3.98, p<.0001) than those with no health condition. Recognising the multiple forms of disadvantage suffered by those with CVD provides a clearer picture of their living standards than just looking at their income alone and the high proportion of individuals with CVD that are suffering from multiple forms of disadvantage should make them a target for policy makers wishing to improve living standards. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  5. Development and initial validation of the Cardiovascular Disease Acceptance and Action Questionnaire (CVD-AAQ) in an Italian sample of cardiac patients

    PubMed Central

    Spatola, Chiara A. M.; Cappella, Emanuele A. M.; Goodwin, Christina L.; Baruffi, Matteo; Malfatto, Gabriella; Facchini, Mario; Castelnuovo, Gianluca; Manzoni, Gian Mauro; Molinari, Enrico

    2014-01-01

    Psychological inflexibility refers to the attempt to decrease internal distress even when doing so is inconsistent with life values, and has been identified as a potential barrier to making and maintaining health behavior changes that are consistent with a heart-healthy lifestyle. Disease- and behavior-specific measures of psychological inflexibility have been developed and utilized in treatment research. However, no specific measure has been created for patients with heart disease. Thus, the CardioVascular Disease Acceptance and Action Questionnaire (CVD-AAQ) was developed. The present study is aimed to evaluate the psychometric properties of the CVD-AAQ and to explore its association with measures of psychological adjustment and cardiovascular risk factors in an Italian sample of 275 cardiac patients. Exploratory factor analysis showed a structural one-factor solution with satisfactory internal consistency and test–retest reliability. The relation with other measures was in the expected direction with stronger correlations for the theoretically consistent variables, supporting convergent and divergent validity. CVD-AAQ scores were associated with general psychological inflexibility, anxiety and depression and inversely correlated with psychological well-being. Moreover, the results showed that CVD-AAQ scores are associated with two relevant risk factors for cardiac patients, namely low adherence to medication and being overweight. In sum, results suggest that the CVD-AAQ is a reliable and valid measure of heart disease-specific psychological inflexibility with interesting clinical applications for secondary prevention care. PMID:25452737

  6. Study of the triton-burnup process in different JET scenarios using neutron monitor based on CVD diamond

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nemtsev, G., E-mail: g.nemtsev@iterrf.ru; Amosov, V.; Meshchaninov, S.

    We present the results of analysis of triton burn-up process using the data from diamond detector. Neutron monitor based on CVD diamond was installed in JET torus hall close to the plasma center. We measure the part of 14 MeV neutrons in scenarios where plasma current varies in a range of 1-3 MA. In this experiment diamond neutron monitor was also able to detect strong gamma bursts produced by runaway electrons arising during the disruptions. We can conclude that CVD diamond detector will contribute to the study of fast particles confinement and help predict the disruption events in future tokamaks.

  7. Alcohol intake in relation to non-fatal and fatal coronary heart disease and stroke: EPIC-CVD case-cohort study.

    PubMed

    Ricci, Cristian; Wood, Angela; Muller, David; Gunter, Marc J; Agudo, Antonio; Boeing, Heiner; van der Schouw, Yvonne T; Warnakula, Samantha; Saieva, Calogero; Spijkerman, Annemieke; Sluijs, Ivonne; Tjønneland, Anne; Kyrø, Cecilie; Weiderpass, Elisabete; Kühn, Tilman; Kaaks, Rudolf; Sánchez, Maria-Jose; Panico, Salvatore; Agnoli, Claudia; Palli, Domenico; Tumino, Rosario; Engström, Gunnar; Melander, Olle; Bonnet, Fabrice; Boer, Jolanda M A; Key, Timothy J; Travis, Ruth C; Overvad, Kim; Verschuren, W M Monique; Quirós, J Ramón; Trichopoulou, Antonia; Papatesta, Eleni-Maria; Peppa, Eleni; Iribas, Conchi Moreno; Gavrila, Diana; Forslund, Ann-Sofie; Jansson, Jan-Håkan; Matullo, Giuseppe; Arriola, Larraitz; Freisling, Heinz; Lassale, Camille; Tzoulaki, Ioanna; Sharp, Stephen J; Forouhi, Nita G; Langenberg, Claudia; Saracci, Rodolfo; Sweeting, Michael; Brennan, Paul; Butterworth, Adam S; Riboli, Elio; Wareham, Nick J; Danesh, John; Ferrari, Pietro

    2018-05-29

    To investigate the association between alcohol consumption (at baseline and over lifetime) and non-fatal and fatal coronary heart disease (CHD) and stroke. Multicentre case-cohort study. A study of cardiovascular disease (CVD) determinants within the European Prospective Investigation into Cancer and nutrition cohort (EPIC-CVD) from eight European countries. 32 549 participants without baseline CVD, comprised of incident CVD cases and a subcohort for comparison. Non-fatal and fatal CHD and stroke (including ischaemic and haemorrhagic stroke). There were 9307 non-fatal CHD events, 1699 fatal CHD, 5855 non-fatal stroke, and 733 fatal stroke. Baseline alcohol intake was inversely associated with non-fatal CHD, with a hazard ratio of 0.94 (95% confidence interval 0.92 to 0.96) per 12 g/day higher intake. There was a J shaped association between baseline alcohol intake and risk of fatal CHD. The hazard ratios were 0.83 (0.70 to 0.98), 0.65 (0.53 to 0.81), and 0.82 (0.65 to 1.03) for categories 5.0-14.9 g/day, 15.0-29.9 g/day, and 30.0-59.9 g/day of total alcohol intake, respectively, compared with 0.1-4.9 g/day. In contrast, hazard ratios for non-fatal and fatal stroke risk were 1.04 (1.02 to 1.07), and 1.05 (0.98 to 1.13) per 12 g/day increase in baseline alcohol intake, respectively, including broadly similar findings for ischaemic and haemorrhagic stroke. Associations with cardiovascular outcomes were broadly similar with average lifetime alcohol consumption as for baseline alcohol intake, and across the eight countries studied. There was no strong evidence for interactions of alcohol consumption with smoking status on the risk of CVD events. Alcohol intake was inversely associated with non-fatal CHD risk but positively associated with the risk of different stroke subtypes. This highlights the opposing associations of alcohol intake with different CVD types and strengthens the evidence for policies to reduce alcohol consumption. Published by the BMJ Publishing

  8. Characterization of CVD micrometer-size diamond (abstract)

    NASA Astrophysics Data System (ADS)

    Ohsumi, K.; Hagiya, K.; Miyamoto, M.; Matsuda, J.; Ohmasa, M.

    1989-07-01

    formed from carbonaceous materials by impact shock or directly formed from vapor. Recent discovery of vapor-growth diamonds in carbonaceous chondrites has generated a renewed interest in the origin of ureilite diamonds. Two types of micrometer-size diamonds were prepared. One of them was grown under low pressure by chemical vapor deposition (CVD) from gaseous mixtures of H2 and CH4, and another was synthesized by shock effect (kindly offered by Nippon Oil & Fats Co., Ltd.) The micro-Laue method was applied to them in order to get information about their microstructures. Two characteristics are recognized in profiles of reflections themselves and in whole patterns of the Laue photographs. The reflections of CVD diamonds are elongated but symmetric in their profiles and are distributed regularly as they are indexed by the diamond lattice, while those of shock effect are also elongated and asymmetric, and are distributed at random as they cannot be indexed. The characteristics observed by the method may be useful to ascribe the origin to CVD or shock effect.

  9. Laser Assisted CVD Growth of A1N and GaN

    DTIC Science & Technology

    1990-08-31

    additional cost sharing. RESEARCH FACILITIES The york is being performed in the Howard University Laser Laboratory. This is a free-standing buildinq...would be used to optimize computer models of the laser induced CVD reactor. FACILITIES AND EQUIPMENT - ADDITIONAL COST SHARING This year Howard ... University has provided $45,000 for the purchase of an excimer laser to be shared by Dr. Crye for the diode laser probe experiments and another Assistant

  10. Toward clean suspended CVD graphene

    DOE PAGES

    Yulaev, Alexander; Univ. of Maryland, College Park, MD; Cheng, Guangjun; ...

    2016-08-26

    The application of suspended graphene as electron transparent supporting media in electron microscopy, vacuum electronics, and micromechanical devices requires the least destructive and maximally clean transfer from their original growth substrate to the target of interest. Here, we use thermally evaporated anthracene films as the sacrificial layer for graphene transfer onto an arbitrary substrate. We show that clean suspended graphene can be achieved via desorbing the anthracene layer at temperatures in the 100 °C to 150 °C range, followed by two sequential annealing steps for the final cleaning, using a Pt catalyst and activated carbon. The cleanliness of the suspendedmore » graphene membranes was analyzed employing the high surface sensitivity of low energy scanning electron microscopy and X-ray photoelectron spectroscopy. A quantitative comparison with two other commonly used transfer methods revealed the superiority of the anthracene approach to obtain a larger area of clean, suspended CVD graphene. Lastly, our graphene transfer method based on anthracene paves the way for integrating cleaner graphene in various types of complex devices, including the ones that are heat and humidity sensitive.« less

  11. Associations between flavan-3-ol intake and CVD risk in the Norfolk cohort of the European Prospective Investigation into Cancer (EPIC-Norfolk)

    PubMed Central

    Vogiatzoglou, Anna; Mulligan, Angela A.; Bhaniani, Amit; Lentjes, Marleen A.H.; McTaggart, Alison; Luben, Robert N.; Heiss, Christian; Kelm, Malte; Merx, Marc W.; Spencer, Jeremy P.E.; Schroeter, Hagen; Khaw, Kay-Tee; Kuhnle, Gunter G.C.

    2015-01-01

    Dietary intervention studies suggest that flavan-3-ol intake can improve vascular function and reduce the risk of cardiovascular diseases (CVD). However, results from prospective studies failed to show a consistent beneficial effect. Associations between flavan-3-ol intake and CVD risk in the Norfolk arm of the European Prospective Investigation into Cancer and Nutrition (EPIC-Norfolk) were investigated. Data were available from 24,885 (11,252 men; 13,633 women) participants, recruited between 1993 and 1997 into the EPIC-Norfolk study. Flavan-3-ol intake was assessed using 7-day food diaries and the FLAVIOLA Flavanol Food Composition database. Missing data for plasma cholesterol and vitamin C were imputed using multiple imputation. Associations between flavan-3-ol intake and blood pressure at baseline were determined using linear regression models. Associations with CVD risk were estimated using Cox regression analyses. Median intake of total flavan-3-ols was 1034 mg/d (range: 0–8531 mg/d) for men and 970 mg/d (0–6695 mg/d) for women, median intake of flavan-3-ol monomers was 233 mg/d (0–3248 mg/d) for men and 217 (0–2712 mg/d) for women. There were no consistent associations between flavan-3-ol monomer intake and baseline systolic and diastolic blood pressure (BP). After 286,147 person-years of follow-up, there were 8463 cardiovascular events and 1987 CVD related deaths; no consistent association between flavan-3-ol intake and CVD risk (HR 0.93, 95% CI: 0.87; 1.00; Q1 vs Q5) or mortality was observed (HR 0.93, 95% CI: 0.84; 1.04). Flavan-3-ol intake in EPIC-Norfolk is not sufficient to achieve a statistically significant reduction in CVD risk. PMID:25795512

  12. The Effects of Exercise Therapy on CVD Risk Factors in Women

    PubMed Central

    Hur, Sun; Kim, Seon-Rye

    2014-01-01

    [Purpose] The purpose of this study was to search for the association of Type D personality and CVD risk factors through comparison of the association of exercise participation with CVD risk factors in women. [Subjects] The research subjects were randomly assigned to four groups: Type D+Exercise (n=12), Type D+non-exercise (n=12), non-Type D+Exercise (n=12), and non-Type D+non-exercise (n=10). The study consisted of 46 participants. [Methods] An aerobic exercise program and meditation were conducted in parallel for 10 months. Stretching was performed for 10 min as a warm-up, and then walking and running on a treadmill at 60 to 70% of HRmax were performed for 40 min three times a week. Blood samples were processed according to standard laboratory procedures. The concentrations of TG and HDL cholesterol were determined enzymatically using a clinical chemistry analyzer (Hitachi High-Technologies Corporation, Tokyo, Japan). [Results] The weight, percentage of body fat, waist circumference, triglyceride concentration, HDL cholesterol concentration, systolic blood pressure, and diastolic blood pressure showed a significant difference between measurement times in the exercise groups. [Conclusion] In conclusion, there were significant differences between groups in terms of cardiovascular disease risk factors. PMID:25276017

  13. S2k-Leitlinie zum Gebrauch von Präparationen zur lokalen Anwendung auf der Haut (Topika).

    PubMed

    Wohlrab, Johannes; Staubach, Petra; Augustin, Matthias; Eisert, Lisa; Hünerbein, Andreas; Nast, Alexander; Reimann, Holger; Strömer, Klaus; Mahler, Vera

    2018-03-01

    Diese Leitlinie richtet sich an Assistenz- und Fachärzte der Dermatologie sowie an Kostenträger und politische Entscheidungsgremien. Die Leitlinie wurde im formellen Konsensusverfahren (S2k) von Dermatologen unter Einbindung von Apothekern erstellt. Die Leitlinie stellt allgemeine Aspekte der Pharmakokinetik sowie der regulatorischen Begrifflichkeiten dar. Es werden Empfehlungen zur Indikation von Magistralrezepturen sowie deren Qualitätssicherung gegeben. Die Bedeutung der galenischen Grundlagen und die Problematik bei einer Substitution gegeneinander verschiedener Grundlagen werden dargestellt. Die Leitlinie umfasst Kriterien zur Auswahl einer adäquaten Grundlage sowie spezifische Aspekte zur Therapieplanung. Die Leitlinie gibt Empfehlungen zum Management bei Unverträglichkeiten gegenüber Bestandteilen der Grundlagen oder Hilfsstoffe. © 2018 The Authors | Journal compilation © Blackwell Verlag GmbH, Berlin.

  14. Probing Growth-Induced Anisotropic Thermal Transport in High-Quality CVD Diamond Membranes by Multifrequency and Multiple-Spot-Size Time-Domain Thermoreflectance.

    PubMed

    Cheng, Zhe; Bougher, Thomas; Bai, Tingyu; Wang, Steven Y; Li, Chao; Yates, Luke; Foley, Brian M; Goorsky, Mark; Cola, Baratunde A; Faili, Firooz; Graham, Samuel

    2018-02-07

    The maximum output power of GaN-based high-electron mobility transistors is limited by high channel temperature induced by localized self-heating, which degrades device performance and reliability. Chemical vapor deposition (CVD) diamond is an attractive candidate to aid in the extraction of this heat and in minimizing the peak operating temperatures of high-power electronics. Owing to its inhomogeneous structure, the thermal conductivity of CVD diamond varies along the growth direction and can differ between the in-plane and out-of-plane directions, resulting in a complex three-dimensional (3D) distribution. Depending on the thickness of the diamond and size of the electronic device, this 3D distribution may impact the effectiveness of CVD diamond in device thermal management. In this work, time-domain thermoreflectance is used to measure the anisotropic thermal conductivity of an 11.8 μm-thick high-quality CVD diamond membrane from its nucleation side. Starting with a spot-size diameter larger than the thickness of the membrane, measurements are made at various modulation frequencies from 1.2 to 11.6 MHz to tune the heat penetration depth and sample the variation in thermal conductivity. We then analyze the data by creating a model with the membrane divided into ten sublayers and assume isotropic thermal conductivity in each sublayer. From this, we observe a two-dimensional gradient of the depth-dependent thermal conductivity for this membrane. The local thermal conductivity goes beyond 1000 W/(m K) when the distance from the nucleation interface only reaches 3 μm. Additionally, by measuring the same region with a smaller spot size at multiple frequencies, the in-plane and cross-plane thermal conductivities are extracted. Through this use of multiple spot sizes and modulation frequencies, the 3D anisotropic thermal conductivity of CVD diamond membrane is experimentally obtained by fitting the experimental data to a thermal model. This work provides an improved

  15. Association of the Magnitude of Weight Loss and Physical Fitness Change on Long-term CVD outcomes: The Look AHEAD Study

    PubMed Central

    2016-01-01

    Background The Look AHEAD Study found no significant reduction in cardiovascular disease (CVD) incidence among adults with diabetes enrolled in an intensive weight loss intervention (ILI) compared to those randomized to diabetes support and education (DSE). We examined whether CVD incidence in Look AHEAD varied by weight or fitness change. Methods Among overweight or obese adults people aged 45–76 with type 2 diabetes in the Look AHEAD study, this observational analysis examined the association of magnitude of weight loss (N=4834) and fitness change (N=4406) over the first year with CVD incidence over a median 10.2 years of follow-up. The primary outcome was a composite of CVD death, myocardial infarction, stroke, or angina hospitalization; the secondary outcome included the same indices plus coronary–artery bypass grafting, carotid endartectomy, percutaneous coronary intervention, hospitalization for congestive heart failure, peripheral vascular disease, or total mortality. Analyses adjusted for baseline differences in weight or fitness, demographics and CVD risk factors. Findings In analyses of the full cohort combining ILI and DSE, persons who lost > 10% body weight in the first year had 21% lower risk of the primary outcome (HR=0.79, 95% CI, 0.64 to 0.98) and a 24% reduced risk of the secondary outcome (HR=0.76, 95% CI, 0.63 to 0.91) relative to those with stable weight/weight gain. Achieving a > 2 MET fitness change was associated with a significant reduction in the secondary outcome (HR=0.77, 95% CI, 0.61 – 0.96) but not the primary outcome (HR=0.78, 0.60 – 1.03). In analyses treating the DSE as the referent group, ILI participants with > 10% weight losses had a 20% lower risk of the primary outcome (HR=0.80 (95% CI, 0.65 – 0.99) and a 21% reduced risk of the secondary outcome (0.79 (95% CI, 0.66 – 0.95); fitness change was not significantly associated with either outcome. Interpretation This secondary analysis of Look AHEAD suggests an

  16. Ballistic Transport Exceeding 28 μm in CVD Grown Graphene.

    PubMed

    Banszerus, Luca; Schmitz, Michael; Engels, Stephan; Goldsche, Matthias; Watanabe, Kenji; Taniguchi, Takashi; Beschoten, Bernd; Stampfer, Christoph

    2016-02-10

    We report on ballistic transport over more than 28 μm in graphene grown by chemical vapor deposition (CVD) that is fully encapsulated in hexagonal boron nitride. The structures are fabricated by an advanced dry van-der-Waals transfer method and exhibit carrier mobilities of up to three million cm(2)/(Vs). The ballistic nature of charge transport is probed by measuring the bend resistance in cross- and square-shaped devices. Temperature-dependent measurements furthermore prove that ballistic transport is maintained exceeding 1 μm up to 200 K.

  17. Colour-causing defects and their related optoelectronic transitions in single crystal CVD diamond.

    PubMed

    Khan, R U A; Cann, B L; Martineau, P M; Samartseva, J; Freeth, J J P; Sibley, S J; Hartland, C B; Newton, M E; Dhillon, H K; Twitchen, D J

    2013-07-10

    Defects causing colour in nitrogen-doped chemical vapour-deposited (CVD) diamond can adversely affect the exceptional optical, electronic and spintronic properties of the material. Several techniques were used to study these defects, namely optical absorption spectroscopy, thermoluminescence (TL) and electron paramagnetic resonance (EPR). From our studies, the defects causing colour in nitrogen-doped CVD diamond are clearly not the same as those causing similar colour in natural diamonds. The brown colour arises due to a featureless absorption profile that decreases in intensity with increasing wavelength, and a broad feature at 360 nm (3.49 eV) that scales in intensity with it. Another prominent absorption band, centred at 520 nm (2.39 eV), is ascribed to the neutral nitrogen-vacancy-hydrogen defect. The defects responsible for the brown colour possess acceptor states that are 1.5 eV from the valence band (VB) edge. The brown colour is removed by heat treatment at 1600 ° C, whereupon new defects possessing shallow (<1 eV) trap states are generated.

  18. Large scale integration of CVD-graphene based NEMS with narrow distribution of resonance parameters

    NASA Astrophysics Data System (ADS)

    Arjmandi-Tash, Hadi; Allain, Adrien; (Vitto Han, Zheng; Bouchiat, Vincent

    2017-06-01

    We present a novel method for the fabrication of the arrays of suspended micron-sized membranes, based on monolayer pulsed-CVD graphene. Such devices are the source of an efficient integration of graphene nano-electro-mechanical resonators, compatible with production at the wafer scale using standard photolithography and processing tools. As the graphene surface is continuously protected by the same polymer layer during the whole process, suspended graphene membranes are clean and free of imperfections such as deposits, wrinkles and tears. Batch fabrication of 100 μm-long multi-connected suspended ribbons is presented. At room temperature, mechanical resonance of electrostatically-actuated devices show narrow distribution of their characteristic parameters with high quality factor and low effective mass and resonance frequencies, as expected for low stress and adsorbate-free membranes. Upon cooling, a sharp increase of both resonant frequency and quality factor is observed, enabling to extract the thermal expansion coefficient of CVD graphene. Comparison with state-of-the-art graphene NEMS is presented.

  19. Oxidation kinetics of CVD silicon carbide and silicon nitride

    NASA Technical Reports Server (NTRS)

    Fox, Dennis S.

    1992-01-01

    The long-term oxidation behavior of pure, monolithic CVD SiC and Si3N4 is studied, and the isothermal oxidation kinetics of these two materials are obtained for the case of 100 hrs at 1200-1500 C in flowing oxygen. Estimates are made of lifetimes at the various temperatures investigated. Parabolic rate constants for SiC are within an order of magnitude of shorter exposure time values reported in the literature. The resulting silica scales are in the form of cristobalite, with cracks visible after exposure. The oxidation protection afforded by silica for these materials is adequate for long service times under isothermal conditions in 1-atm dry oxygen.

  20. Traditional CVD risk factors and socio-economic deprivation in Roma minority population of Croatia.

    PubMed

    Zeljko, Hrvojka; Skarić-Jurić, Tatjana; Narancic, Nina Smolej; Salihović, Marijana Pericić; Klarić, Irena Martinović; Barbalić, Maja; Starcević, Boris; Lauc, Lovorka Barać; Janićijević, Branka

    2008-09-01

    Researches into health inequalities consistently show disadvantages in health status, morbidity and mortality for various ethnic minority groups. Current knowledge about prevention of cardiovascular diseases (CVD) mainly derives from studies carried out in populations of European origin while the evidences involving Roma population are scarce. Roma, an ethnic minority of northern Indian origin, live in many countries throughout the world and are well known for preserved traditions and resistance to assimilation. They are most often marginalized economically, spatially, politically and in terms of culture. In order to assess the health status and health-related lifestyle attributes, a multidisciplinary anthropological and epidemiological community-based study was carried out including a total of 423 members of the Bayash Roma minority population living in two regions of Croatia (144 men and 279 women, aged 18-84 yrs). Hypertension (HT) was found in 24.8% Bayash Roma (21.5% men and 26.5% women) using standard diagnostic criteria (i.e. BP > or = 140/90 mm Hg or taking antihypertensive therapy). The prevalence increases from 5.9% in the age group 18-34 yrs; 35.0% in the age group 35-64 yrs, and 51.4% in the age group 65+ yrs. The prevalence of hypertension in the Bayash Roma is almost half of the magnitude of what is usually reported for the general population of Croatia. It is also lower when compared with other European populations and this finding is not due to comparatively younger average age of the Bayash sample. The significant association of hypertension with age and BMI was confirmed in this study and the importance of non-traditional SES-related CVD risk factors was highlighted. Smoking is a part of traditional Roma life-style and with 70% of smokers almost the entire population is equally exposed to this risk factor in their family environment. Since homogenously distributed, this risk factor did not show to be a significant predictor of hypertension. The

  1. Creep and Rupture Strength of an Advanced CVD SiC Fiber

    NASA Technical Reports Server (NTRS)

    Goldsby, J. C.; Yun, H. M.; DiCarlo, J. A.

    1997-01-01

    In the as-produced condition the room temperature strength (approx. 6 GPa) of Textron Specialty Materials' 50 microns CVD SiC fiber represents the highest value thus far obtained for commercially produced polycrystalline SiC fibers. To understand whether this strength can be maintained after composite processing conditions, high temperature studies were performed on the effects of time, stress, and environment on 1400 deg. C tensile creep strain and stress rupture on as-produced, chemically vapor deposited SiC fibers. Creep strain results were consistent, allowing an evaluation of time and stress effects. Test environment had no influence on creep strain but I hour annealing at 1600 deg. C in argon gas significantly reduced the total creep strain and increased the stress dependence. This is attributed to changes in the free carbon morphology and its distribution within the CVD SiC fiber. For the as-produced and annealed fibers, strength at 1400 deg. C was found to decrease from a fast fracture value of 2 GPa to a 100-hr rupture strength value of 0. 8 GPa. In addition a loss of fast fracture strength from 6 GPa is attributed to thermally induced changes in the outer carbon coating and microstructure. Scatter in rupture times made a definitive analysis of environmental and annealing effects on creep strength difficult.

  2. Origins of Moiré Patterns in CVD-grown MoS2 Bilayer Structures at the Atomic Scales.

    PubMed

    Wang, Jin; Namburu, Raju; Dubey, Madan; Dongare, Avinash M

    2018-06-21

    The chemical vapor deposition (CVD)-grown two-dimensional molybdenum disulfide (MoS 2 ) structures comprise of flakes of few layers with different dimensions. The top layers are relatively smaller in size than the bottom layers, resulting in the formation of edges/steps across adjacent layers. The strain response of such few-layer terraced structures is therefore likely to be different from exfoliated few-layered structures with similar dimensions without any terraces. In this study, the strain response of CVD-grown few-layered MoS 2 terraced structures is investigated at the atomic scales using classic molecular dynamics (MD) simulations. MD simulations suggest that the strain relaxation of CVD-grown triangular terraced structures is observed in the vertical displacement of the atoms across the layers that results in the formation of Moiré patterns. The Moiré islands are observed to nucleate at the corners or edges of the few-layered structure and propagate inwards under both tensile and compressive strains. The nucleation of these islands is observed to happen at tensile strains of ~ 2% and at compressive strains of ~2.5%. The vertical displacements of the atoms and the dimensions of the Moiré islands predicted using the MD simulation are in excellent agreement with that observed experimentally.

  3. Surface modification of pitch-based spherical activated carbon by CVD of NH 3 to improve its adsorption to uric acid

    NASA Astrophysics Data System (ADS)

    Liu, Chaojun; Liang, Xiaoyi; Liu, Xiaojun; Wang, Qin; Zhan, Liang; Zhang, Rui; Qiao, Wenming; Ling, Licheng

    2008-08-01

    Surface chemistry of pitch-based spherical activated carbon (PSAC) was modified by chemical vapor deposition of NH 3 (NH 3-CVD) to improve the adsorption properties of uric acid. The texture and surface chemistry of PSAC were studied by N 2 adsorption, pH PZC (point of zero charge), acid-base titration and X-ray photoelectron spectroscopy (XPS). NH 3-CVD has a limited effect on carbon textural characteristics but it significantly changed the surface chemical properties, resulting in positive effects on uric acid adsorption. After modification by NH 3-CVD, large numbers of nitrogen-containing groups (especially valley-N and center-N) are introduced on the surface of PSAC, which is responsible for the increase of pH PZC, surface basicity and uric acid adsorption capacity. Pseudo-second-order kinetic model can be used to describe the dynamic adsorption of uric acid on PSAC, and the thermodynamic parameters show that the adsorption of uric acid on PSAC is spontaneous, endothermic and irreversible process in nature.

  4. Polycrystalline CVD diamond device level modeling for particle detection applications

    NASA Astrophysics Data System (ADS)

    Morozzi, A.; Passeri, D.; Kanxheri, K.; Servoli, L.; Lagomarsino, S.; Sciortino, S.

    2016-12-01

    Diamond is a promising material whose excellent physical properties foster its use for radiation detection applications, in particular in those hostile operating environments where the silicon-based detectors behavior is limited due to the high radiation fluence. Within this framework, the application of Technology Computer Aided Design (TCAD) simulation tools is highly envisaged for the study, the optimization and the predictive analysis of sensing devices. Since the novelty of using diamond in electronics, this material is not included in the library of commercial, state-of-the-art TCAD software tools. In this work, we propose the development, the application and the validation of numerical models to simulate the electrical behavior of polycrystalline (pc)CVD diamond conceived for diamond sensors for particle detection. The model focuses on the characterization of a physically-based pcCVD diamond bandgap taking into account deep-level defects acting as recombination centers and/or trap states. While a definite picture of the polycrystalline diamond band-gap is still debated, the effect of the main parameters (e.g. trap densities, capture cross-sections, etc.) can be deeply investigated thanks to the simulated approach. The charge collection efficiency due to β -particle irradiation of diamond materials provided by different vendors and with different electrode configurations has been selected as figure of merit for the model validation. The good agreement between measurements and simulation findings, keeping the traps density as the only one fitting parameter, assesses the suitability of the TCAD modeling approach as a predictive tool for the design and the optimization of diamond-based radiation detectors.

  5. A novel Mo-W interlayer approach for CVD diamond deposition on steel

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kundrát, Vojtěch; Sullivan, John; Ye, Haitao, E-mail: h.ye@aston.ac.uk

    Steel is the most widely used material in engineering for its cost/performance ratio and coatings are routinely applied on its surface to further improve its properties. Diamond coated steel parts are an option for many demanding industrial applications through prolonging the lifetime of steel parts, enhancement of tool performance as well as the reduction of wear rates. Direct deposition of diamond on steel using conventional chemical vapour deposition (CVD) processes is known to give poor results due to the preferential formation of amorphous carbon on iron, nickel and other elements as well as stresses induced from the significant difference inmore » the thermal expansion coefficients of those materials. This article reports a novel approach of deposition of nanocrystalline diamond coatings on high-speed steel (M42) substrates using a multi-structured molybdenum (Mo) – tungsten (W) interlayer to form steel/Mo/Mo-W/W/diamond sandwich structures which overcome the adhesion problem related to direct magnetron sputtering deposition of pure tungsten. Surface, interface and tribology properties were evaluated to understand the role of such an interlayer structure. The multi-structured Mo-W interlayer has been proven to improve the adhesion between diamond films and steel substrates by acting as an effective diffusion barrier during the CVD diamond deposition.« less

  6. A novel Mo-W interlayer approach for CVD diamond deposition on steel

    NASA Astrophysics Data System (ADS)

    Kundrát, Vojtěch; Zhang, Xiaoling; Cooke, Kevin; Sun, Hailin; Sullivan, John; Ye, Haitao

    2015-04-01

    Steel is the most widely used material in engineering for its cost/performance ratio and coatings are routinely applied on its surface to further improve its properties. Diamond coated steel parts are an option for many demanding industrial applications through prolonging the lifetime of steel parts, enhancement of tool performance as well as the reduction of wear rates. Direct deposition of diamond on steel using conventional chemical vapour deposition (CVD) processes is known to give poor results due to the preferential formation of amorphous carbon on iron, nickel and other elements as well as stresses induced from the significant difference in the thermal expansion coefficients of those materials. This article reports a novel approach of deposition of nanocrystalline diamond coatings on high-speed steel (M42) substrates using a multi-structured molybdenum (Mo) - tungsten (W) interlayer to form steel/Mo/Mo-W/W/diamond sandwich structures which overcome the adhesion problem related to direct magnetron sputtering deposition of pure tungsten. Surface, interface and tribology properties were evaluated to understand the role of such an interlayer structure. The multi-structured Mo-W interlayer has been proven to improve the adhesion between diamond films and steel substrates by acting as an effective diffusion barrier during the CVD diamond deposition.

  7. Ein statistisches Modell zum Einfluß der thermischen Bewegung auf NMR-Festkörperspektren

    NASA Astrophysics Data System (ADS)

    Ploss, W.; Freude, D.; Pfeifer, H.; Schmiedel, H.

    Es wird ein statistisches Modell zum Einfluß der thermischen Bewegung auf die NMR-Linienform vorgestellt, das die Verschmälerung von Festkörper-Spektren bei wachsender Temperatur beschreibt. Das Modell geht von der Annahme aus, daß nach einer Ortsveränderung eines Kerns infolge thermischer Bewegung jede beliebige Kernresonanzfrequenz mit der durch das Festkörperspektrum vorgegebenen Wahrscheinlichkeit angenommen werden kann. Am Beispiel der Festkörper-Gaußlinie wird der Unterschied zu dem bekannten Modell von ANDERSON und WEISS verdeutlicht.Translated AbstractA Statistical Model for the Influence of Thermal Motion on N. M. R. Spectra in SolidsA theory is proposed which allows to describe the narrowing of n. m. r.-line width in the presence of thermal motions of the spins. The model is based on the assumption, that the local resonance frequency of a given spin immediately after the jump is distributed according to the n. m. r.-line shape of the rigid lattice. The difference to the well-known ANDERSON-WEISS-model of spectral narrowing is demonstrated for a gaussian line shape.

  8. Potential economic impact of increasing low dose aspirin usage on CVD in the US.

    PubMed

    Manson, Stephanie C; Benedict, Agnes; Pan, Feng; Wittrup-Jensen, Kim U; Fendrick, A Mark

    2010-10-01

    Cardiovascular disease (CVD) is a leading cause of death in the US and Western Europe, but regular use of preventive low-dose aspirin has proven effective in preventing CVD events. The purpose of this study was to explore the potential economic impact in the US if preventive aspirin usage were to be increased in line with clinical guidelines for primary and secondary prevention. The risk profile of the US population was characterized using NHANES data, and Framingham cardiovascular risk equations were applied to calculate risk for myocardial infarction, angina and ischemic stroke according to age and gender. Primary and secondary patients were considered separately. Using publicly available unit costs, a budget impact model calculated the annual impact of increased preventive aspirin usage considering gastrointestinal bleeding and hemorrhagic stroke adverse events and diminishing aspirin adherence over a 10-year time horizon. In a base population of 1,000,000 patients, full implementation of clinical guidelines would potentially prevent an additional 1273 myocardial infarctions, 2184 angina episodes and 565 ischemic strokes in primary prevention patients and an additional 578 myocardial infarctions, and 607 ischemic strokes in secondary prevention patients. This represents a total savings of $79.6 million for primary prevention and $32.2 million for secondary and additional out-of-pocket expense to patients of $29.0 million for primary prevention and $2.6 million for secondary prevention for the cost of aspirin. This budgetary model suggests that there is a strong economic case, both for payers and society, to encourage aspirin use for patients at appropriate risk and per clinical guidelines. It also provides an example of how minimizing costs do not necessarily have to imply a rationing of care. Limitations include the exclusion of other CVD interventions in the analysis.

  9. Control of Reaction Surface in Low Temperature CVD to Enhance Nucleation and Conformal Coverage

    ERIC Educational Resources Information Center

    Kumar, Navneet

    2009-01-01

    The Holy Grail in CVD community is to find precursors that can afford the following: good nucleation on a desired substrate and conformal deposition in high AR features. Good nucleation is not only necessary for getting ultra-thin films at low thicknesses; it also offers films that are smooth at higher thickness values. On the other hand,…

  10. Reducing salt intake for prevention of cardiovascular diseases in high-risk patients by advanced health education intervention (RESIP-CVD study), Northern Thailand: study protocol for a cluster randomized trial

    PubMed Central

    2012-01-01

    Background Decreasing salt consumption can prevent cardiovascular diseases (CVD). Practically, it is difficult to promote people’s awareness of daily salt intake and to change their eating habits in terms of reducing salt intake for better cardiovascular health. Health education programs visualizing daily dietary salt content and intake may promote lifestyle changes in patients at high risk of cardiovascular diseases. Methods/Design This is a cluster randomized trial. A total of 800 high-CVD-risk patients attending diabetes and hypertension clinics at health centers in Muang District, Chiang Rai province, Thailand, will be studied with informed consent. A health center recruiting 100 participants is a cluster, the unit of randomization. Eight clusters will be randomized into intervention and control arms and followed up for 1 year. Within the intervention clusters the following will be undertaken: (1) salt content in the daily diet will be measured and shown to study participants; (2) 24-hour salt intake will be estimated in overnight-collected urine and the results shown to the participants; (3) a dietician will assist small group health education classes in cooking meals with less salt. The primary outcome is blood pressure change at the 1-year follow-up. Secondary outcomes at the 1-year follow-up are estimated 24-hoursalt intake, incidence of CVD events and CVD death. The intention-to-treat analysis will be followed. Blood pressure and estimated 24-hour salt intake will be compared between intervention and control groups at the cluster and individual level at the 1-year follow-up. Clinical CVD events and deaths will be analyzed by time-event analysis. Retinal blood vessel calibers of CVD-risk patients will be assessed cross-sectionally. Behavioral change to reduce salt intake and the influencing factors will be determined by structured equation model (SEM). Multilevel regression analyses will be applied. Finally, the cost effectiveness of the intervention

  11. Reducing salt intake for prevention of cardiovascular diseases in high-risk patients by advanced health education intervention (RESIP-CVD study), Northern Thailand: study protocol for a cluster randomized trial.

    PubMed

    Aung, Myo Nyein; Yuasa, Motoyuki; Moolphate, Saiyud; Nedsuwan, Supalert; Yokokawa, Hidehiro; Kitajima, Tsutomu; Minematsu, Kazuo; Tanimura, Susumu; Fukuda, Hiroshi; Hiratsuka, Yoshimune; Ono, Koichi; Kawai, Sachio; Marui, Eiji

    2012-09-04

    Decreasing salt consumption can prevent cardiovascular diseases (CVD). Practically, it is difficult to promote people's awareness of daily salt intake and to change their eating habits in terms of reducing salt intake for better cardiovascular health. Health education programs visualizing daily dietary salt content and intake may promote lifestyle changes in patients at high risk of cardiovascular diseases. This is a cluster randomized trial. A total of 800 high-CVD-risk patients attending diabetes and hypertension clinics at health centers in Muang District, Chiang Rai province, Thailand, will be studied with informed consent. A health center recruiting 100 participants is a cluster, the unit of randomization. Eight clusters will be randomized into intervention and control arms and followed up for 1 year. Within the intervention clusters the following will be undertaken: (1) salt content in the daily diet will be measured and shown to study participants; (2) 24-hour salt intake will be estimated in overnight-collected urine and the results shown to the participants; (3) a dietician will assist small group health education classes in cooking meals with less salt. The primary outcome is blood pressure change at the 1-year follow-up. Secondary outcomes at the 1-year follow-up are estimated 24-hoursalt intake, incidence of CVD events and CVD death. The intention-to-treat analysis will be followed.Blood pressure and estimated 24-hour salt intake will be compared between intervention and control groups at the cluster and individual level at the 1-year follow-up. Clinical CVD events and deaths will be analyzed by time-event analysis. Retinal blood vessel calibers of CVD-risk patients will be assessed cross-sectionally. Behavioral change to reduce salt intake and the influencing factors will be determined by structured equation model (SEM). Multilevel regression analyses will be applied. Finally, the cost effectiveness of the intervention will be analyzed. This study is

  12. Nanocrystalline sp{sup 2} and sp{sup 3} carbons: CVD synthesis and applications

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Terranova, M. L.; Rossi, M.; Tamburri, E., E-mail: emanuela.tamburri@uniroma2.it

    The design and production of innovative materials based on nanocrystalline sp{sup 2}- and sp{sup 3}-coordinated carbons is presently a focus of the scientific community. We present a review of the nanostructures obtained in our labs using a series of synthetic routes, which make use of chemical vapor deposition (CVD) techniques for the selective production of non-planar graphitic nanostructures, nanocrystalline diamonds, and hybrid two-phase nanostructures.

  13. Pharmacological Targeting of the Atherogenic Dyslipidemia Complex: The Next Frontier in CVD Prevention Beyond Lowering LDL Cholesterol.

    PubMed

    Xiao, Changting; Dash, Satya; Morgantini, Cecilia; Hegele, Robert A; Lewis, Gary F

    2016-07-01

    Notwithstanding the effectiveness of lowering LDL cholesterol, residual CVD risk remains in high-risk populations, including patients with diabetes, likely contributed to by non-LDL lipid abnormalities. In this Perspectives in Diabetes article, we emphasize that changing demographics and lifestyles over the past few decades have resulted in an epidemic of the "atherogenic dyslipidemia complex," the main features of which include hypertriglyceridemia, low HDL cholesterol levels, qualitative changes in LDL particles, accumulation of remnant lipoproteins, and postprandial hyperlipidemia. We briefly review the underlying pathophysiology of this form of dyslipidemia, in particular its association with insulin resistance, obesity, and type 2 diabetes, and the marked atherogenicity of this condition. We explain the failure of existing classes of therapeutic agents such as fibrates, niacin, and cholesteryl ester transfer protein inhibitors that are known to modify components of the atherogenic dyslipidemia complex. Finally, we discuss targeted repurposing of existing therapies and review promising new therapeutic strategies to modify the atherogenic dyslipidemia complex. We postulate that targeting the central abnormality of the atherogenic dyslipidemia complex, the elevation of triglyceride-rich lipoprotein particles, represents a new frontier in CVD prevention and is likely to prove the most effective strategy in correcting most aspects of the atherogenic dyslipidemia complex, thereby preventing CVD events. © 2016 by the American Diabetes Association. Readers may use this article as long as the work is properly cited, the use is educational and not for profit, and the work is not altered.

  14. Advances in the Development of a WCl6 CVD System for Coating UO2 Powders with Tungsten

    NASA Technical Reports Server (NTRS)

    Mireles, Omar R.; Tieman, Alyssa; Broadway, Jeramie; Hickman, Robert

    2013-01-01

    W-UO2 CERMET fuels are under development to enable Nuclear Thermal Propulsion (NTP) for deep space exploration. Research efforts with an emphasis on fuel fabrication, testing, and identification of potential risks is underway. One primary risk is fuel loss due to CTE mismatch between W and UO2 and the grain boundary structure of W particles resulting in higher thermal stresses. Mechanical failure can result in significant reduction of the UO2 by hot hydrogen. Fuel loss can be mitigated if the UO2 particles are coated with a layer of high density tungsten before the consolidation process. This paper discusses the work to date, results, and advances of a fluidized bed chemical vapor deposition (CVD) system that utilizes the H2-WCl6 reduction process. Keywords: Space, Nuclear, Thermal, Propulsion, Fuel, CERMET, CVD, Tungsten, Uranium

  15. Process stability and morphology optimization of very thick 4H-SiC epitaxial layers grown by chloride-based CVD

    NASA Astrophysics Data System (ADS)

    Yazdanfar, M.; Stenberg, P.; Booker, I. D.; Ivanov, I. G.; Kordina, O.; Pedersen, H.; Janzén, E.

    2013-10-01

    The development of a chemical vapor deposition (CVD) process for very thick silicon carbide (SiC) epitaxial layers suitable for high power devices is demonstrated by epitaxial growth of 200 μm thick, low doped 4H-SiC layers with excellent morphology at growth rates exceeding 100 μm/h. The process development was done in a hot wall CVD reactor without rotation using both SiCl4 and SiH4+HCl precursor approaches to chloride based growth chemistry. A C/Si ratio <1 and an optimized in-situ etch are shown to be the key parameters to achieve 200 μm thick, low doped epitaxial layers with excellent morphology.

  16. One-dimensional surface-imprinted polymeric nanotubes for specific biorecognition by initiated chemical vapor deposition (iCVD).

    PubMed

    Ince, Gozde Ozaydin; Armagan, Efe; Erdogan, Hakan; Buyukserin, Fatih; Uzun, Lokman; Demirel, Gokhan

    2013-07-24

    Molecular imprinting is a powerful, generic, and cost-effective technique; however, challenges still remain related to the fabrication and development of these systems involving nonhomogeneous binding sites, insufficient template removing, incompatibility with aqueous media, low rebinding capacity, and slow mass transfer. The vapor-phase deposition of polymers is a unique technique because of the conformal nature of coating and offers new possibilities in a number of applications including sensors, microfluidics, coating, and bioaffinity platforms. Herein, we demonstrated a simple but versatile concept to generate one-dimensional surface-imprinted polymeric nanotubes within anodic aluminum oxide (AAO) membranes based on initiated chemical vapor deposition (iCVD) technique for biorecognition of immunoglobulin G (IgG). It is reported that the fabricated surface-imprinted nanotubes showed high binding capacity and significant specific recognition ability toward target molecules compared with the nonimprinted forms. Given its simplicity and universality, the iCVD method can offer new possibilities in the field of molecular imprinting.

  17. Epitaxial ferromagnetic single clusters and smooth continuous layers on large area MgO/CVD graphene substrates

    NASA Astrophysics Data System (ADS)

    Godel, Florian; Meny, Christian; Doudin, Bernard; Majjad, Hicham; Dayen, Jean-François; Halley, David

    2018-02-01

    We report on the fabrication of ferromagnetic thin layers separated by a MgO dielectric barrier from a graphene-covered substrate. The growth of ferromagnetic metal layers—Co or Ni0.8Fe0.2—is achieved by Molecular Beam Epitaxy (MBE) on a 3 nm MgO(111) epitaxial layer deposited on graphene. In the case of a graphene, grown by chemical vapor deposition (CVD) over Ni substrates, an annealing at 450 °C, under ultra-high-vacuum (UHV) conditions, leads to the dewetting of the ferromagnetic layers, forming well-defined flat facetted clusters whose shape reflects the substrate symmetry. In the case of CVD graphene transferred on SiO2, no dewetting is observed after same annealing. We attribute this difference to the mechanical stress states induced by the substrate, illustrating how it matters for epitaxial construction through graphene. Controlling the growth parameters of such magnetic single objects or networks could benefit to new architectures for catalysis or spintronic applications.

  18. Shigella flexneri 2a Strain CVD 1207, with Specific Deletions in virG, sen, set, and guaBA, Is Highly Attenuated in Humans

    PubMed Central

    Kotloff, Karen L.; Noriega, Fernando R.; Samandari, Taraz; Sztein, Marcelo B.; Losonsky, Genevieve A.; Nataro, James P.; Picking, William D.; Barry, Eileen M.; Levine, Myron M.

    2000-01-01

    A phase 1 clinical trial was conducted among 35 healthy adult volunteers to evaluate the safety, immunogenicity, and shedding of different doses of CVD 1207, a live attenuated Shigella flexneri 2a vaccine candidate with specific deletion mutations in virG, sen, set, and guaBA. CVD 1207 retains the ability to invade epithelial cells but cannot effectively spread intercellularly after invasion (ΔvirG), does not produce enterotoxin (Δsen and Δset), and has limited proliferation in vivo (ΔguaBA). In a consecutive fashion, groups of three to seven subjects ingested a single oral dose of CVD 1207 at an inoculum of either 106, 107, 108, 109, or 1010 CFU. CVD 1207 was remarkably well-tolerated at inocula as high as 108 CFU. In comparison, one of 12 subjects who received 109 CFU experienced mild diarrhea and another experienced a single episode of emesis. One of five subjects who received 1010 CFU experienced watery diarrhea and emesis. All subjects who ingested doses of 108 to 1010 CFU excreted the vaccine; in 23 of 25, the duration of excretion was ≤3 days. A dose-related, immunoglobulin A antibody-secreting cell (ASC) response to S. flexneri 2a O-specific lipopolysaccharide was seen, with geometric mean peak values of 6.1 to 35.2 ASCs/106 peripheral blood mononuclear cells (PBMC) among recipients of 107 to 1010 CFU. The cytokine response to Shigella-specific antigens observed in volunteers' PBMC following vaccination suggested a Th1 pattern with stimulation of gamma interferon and absence of interleukin 4 (IL-4) or IL-5. CVD 1207 represents a Shigella live oral vaccine strain prepared from wild-type S. flexneri 2a by rational use of recombinant DNA technology that achieves a remarkable degree of attenuation compared with earlier recombinant strains, even when administered at high dosage. PMID:10678904

  19. Unravelling merging behaviors and electrostatic properties of CVD-grown monolayer MoS{sub 2} domains

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hao, Song; Yang, Bingchu, E-mail: bingchuyang@csu.edu.cn; Hunan Key Laboratory for Super-Microstructure and Ultrafast Process, Central South University, 932 South Lushan Road, Changsha 410012

    The presence of grain boundaries is inevitable for chemical vapor deposition (CVD)-grown MoS{sub 2} domains owing to various merging behaviors, which greatly limits its potential applications in novel electronic and optoelectronic devices. It is therefore of great significance to unravel the merging behaviors of the synthesized polygon shape MoS{sub 2} domains. Here we provide systematic investigations of merging behaviors and electrostatic properties of CVD-grown polycrystalline MoS{sub 2} crystals by multiple means. Morphological results exhibit various polygon shape features, ascribed to polycrystalline crystals merged with triangle shape MoS{sub 2} single crystals. The thickness of triangle and polygon shape MoS{sub 2} crystalsmore » is identical manifested by Raman intensity and peak position mappings. Three merging behaviors are proposed to illustrate the formation mechanisms of observed various polygon shaped MoS{sub 2} crystals. The combined photoemission electron microscopy and kelvin probe force microscopy results reveal that the surface potential of perfect merged crystals is identical, which has an important implication for fabricating MoS{sub 2}-based devices.« less

  20. Dimensionless Numbers Expressed in Terms of Common CVD Process Parameters

    NASA Technical Reports Server (NTRS)

    Kuczmarski, Maria A.

    1999-01-01

    A variety of dimensionless numbers related to momentum and heat transfer are useful in Chemical Vapor Deposition (CVD) analysis. These numbers are not traditionally calculated by directly using reactor operating parameters, such as temperature and pressure. In this paper, these numbers have been expressed in a form that explicitly shows their dependence upon the carrier gas, reactor geometry, and reactor operation conditions. These expressions were derived for both monatomic and diatomic gases using estimation techniques for viscosity, thermal conductivity, and heat capacity. Values calculated from these expressions compared well to previously published values. These expressions provide a relatively quick method for predicting changes in the flow patterns resulting from changes in the reactor operating conditions.

  1. Behavioral Counseling to Promote a Healthful Diet and Physical Activity for CVD Prevention in Adults with Risk Factors

    MedlinePlus

    ... Promote a Healthful Diet and Physical Activity for Cardiovascular Disease Prevention in Adults with Cardiovascular Risk Factors The ... Promote a Healthful Diet and Physical Activity for Cardiovascular Disease (CVD) Prevention in Adults with Cardiovascular Risk Factors. ...

  2. Optical characterization of single-crystal diamond grown by DC arc plasma jet CVD

    NASA Astrophysics Data System (ADS)

    Hei, Li-fu; Zhao, Yun; Wei, Jun-jun; Liu, Jin-long; Li, Cheng-ming; Lü, Fan-xiu

    2017-12-01

    Optical centers of single-crystal diamond grown by DC arc plasma jet chemical vapor deposition (CVD) were examined using a low-temperature photoluminescence (PL) technique. The results show that most of the nitrogen-vacancy (NV) complexes are present as NV- centers, although some H2 and H3 centers and B-aggregates are also present in the single-crystal diamond because of nitrogen aggregation resulting from high N2 incorporation and the high mobility of vacancies under growth temperatures of 950-1000°C. Furthermore, emissions of radiation-induced defects were also detected at 389, 467.5, 550, and 588.6 nm in the PL spectra. The reason for the formation of these radiation-induced defects is not clear. Although a Ni-based alloy was used during the diamond growth, Ni-related emissions were not detected in the PL spectra. In addition, the silicon-vacancy (Si-V)-related emission line at 737 nm, which has been observed in the spectra of many previously reported microwave plasma chemical vapor deposition (MPCVD) synthetic diamonds, was absent in the PL spectra of the single-crystal diamond prepared in this work. The high density of NV- centers, along with the absence of Ni-related defects and Si-V centers, makes the single-crystal diamond grown by DC arc plasma jet CVD a promising material for applications in quantum computing.

  3. Electronic structure of polycrystalline CVD-graphene revealed by Nano-ARPES

    NASA Astrophysics Data System (ADS)

    Chen, Chaoyu; Avila, José; Asensio, Maria C.

    2017-06-01

    The ability to explore electronic structure and their role in determining material’s macroscopic behaviour is essential to explain and engineer functions of material and device. Since its debut in 2004, graphene has attracted global research interest due to its unique properties. Chemical vapor deposition (CVD) has emerged as an important method for the massive preparation and production of graphene for various applications. Here by employing angle-resolved photoemission spectroscopy with nanoscale spatial resolution ˜ 100 nm (Nano-ARPES), we describe the approach to measure the electronic structure of polycrystalline graphene on copper foils, demonstrating the power of Nano-ARPES to detect the electronic structure of microscopic single crystalline domains, being fully compatible with conventional ARPES. Similar analysis could be employed to other microscopic materials

  4. Large-scale synthesis of NbS2 nanosheets with controlled orientation on graphene by ambient pressure CVD.

    PubMed

    Ge, Wanyin; Kawahara, Kenji; Tsuji, Masaharu; Ago, Hiroki

    2013-07-07

    We report ambient pressure chemical vapor deposition (CVD) growth of single-crystalline NbS2 nanosheets with controlled orientation. On Si and SiO2 substrates, NbS2 nanosheets grow almost perpendicular to the substrate surface. However, when we apply transferred CVD graphene on SiO2 as a substrate, NbS2 sheets grow laterally lying on the graphene. The NbS2 sheets show the triangular and hexagonal shapes with a thickness of about 20-200 nm and several micrometres in the lateral dimension. Analyses based on X-ray diffraction and Raman spectroscopy indicate that the NbS2 nanosheets are single crystalline 3R-type with a rhombohedral structure of R3m space group. Our findings on the formation of highly aligned NbS2 nanosheets on graphene give new insight into the formation mechanism of NbS2 and would contribute to the templated growth of various layered materials.

  5. Shigella flexneri 2a strain CVD 1207, with specific deletions in virG, sen, set, and guaBA, is highly attenuated in humans.

    PubMed

    Kotloff, K L; Noriega, F R; Samandari, T; Sztein, M B; Losonsky, G A; Nataro, J P; Picking, W D; Barry, E M; Levine, M M

    2000-03-01

    A phase 1 clinical trial was conducted among 35 healthy adult volunteers to evaluate the safety, immunogenicity, and shedding of different doses of CVD 1207, a live attenuated Shigella flexneri 2a vaccine candidate with specific deletion mutations in virG, sen, set, and guaBA. CVD 1207 retains the ability to invade epithelial cells but cannot effectively spread intercellularly after invasion (DeltavirG), does not produce enterotoxin (Deltasen and Deltaset), and has limited proliferation in vivo (DeltaguaBA). In a consecutive fashion, groups of three to seven subjects ingested a single oral dose of CVD 1207 at an inoculum of either 10(6), 10(7), 10(8), 10(9), or 10(10) CFU. CVD 1207 was remarkably well-tolerated at inocula as high as 10(8) CFU. In comparison, one of 12 subjects who received 10(9) CFU experienced mild diarrhea and another experienced a single episode of emesis. One of five subjects who received 10(10) CFU experienced watery diarrhea and emesis. All subjects who ingested doses of 10(8) to 10(10) CFU excreted the vaccine; in 23 of 25, the duration of excretion was CVD 1207 represents a Shigella live oral vaccine strain prepared from wild-type S. flexneri 2a by rational use of recombinant DNA technology that achieves a remarkable degree of attenuation compared with earlier recombinant strains, even when administered at high dosage.

  6. Gene-centric Association Signals for Lipids and Apolipoproteins Identified via the HumanCVD BeadChip

    PubMed Central

    Talmud, Philippa J.; Drenos, Fotios; Shah, Sonia; Shah, Tina; Palmen, Jutta; Verzilli, Claudio; Gaunt, Tom R.; Pallas, Jacky; Lovering, Ruth; Li, Kawah; Casas, Juan Pablo; Sofat, Reecha; Kumari, Meena; Rodriguez, Santiago; Johnson, Toby; Newhouse, Stephen J.; Dominiczak, Anna; Samani, Nilesh J.; Caulfield, Mark; Sever, Peter; Stanton, Alice; Shields, Denis C.; Padmanabhan, Sandosh; Melander, Olle; Hastie, Claire; Delles, Christian; Ebrahim, Shah; Marmot, Michael G.; Smith, George Davey; Lawlor, Debbie A.; Munroe, Patricia B.; Day, Ian N.; Kivimaki, Mika; Whittaker, John; Humphries, Steve E.; Hingorani, Aroon D.

    2009-01-01

    Blood lipids are important cardiovascular disease (CVD) risk factors with both genetic and environmental determinants. The Whitehall II study (n = 5592) was genotyped with the gene-centric HumanCVD BeadChip (Illumina). We identified 195 SNPs in 16 genes/regions associated with 3 major lipid fractions and 2 apolipoprotein components at p < 10−5, with the associations being broadly concordant with prior genome-wide analysis. SNPs associated with LDL cholesterol and apolipoprotein B were located in LDLR, PCSK9, APOB, CELSR2, HMGCR, CETP, the TOMM40-APOE-C1-C2-C4 cluster, and the APOA5-A4-C3-A1 cluster; SNPs associated with HDL cholesterol and apolipoprotein AI were in CETP, LPL, LIPC, APOA5-A4-C3-A1, and ABCA1; and SNPs associated with triglycerides in GCKR, BAZ1B, MLXIPL, LPL, and APOA5-A4-C3-A1. For 48 SNPs in previously unreported loci that were significant at p < 10−4 in Whitehall II, in silico analysis including the British Women's Heart and Health Study, BRIGHT, ASCOT, and NORDIL studies (total n > 12,500) revealed previously unreported associations of SH2B3 (p < 2.2 × 10−6), BMPR2 (p < 2.3 × 10−7), BCL3/PVRL2 (flanking APOE; p < 4.4 × 10−8), and SMARCA4 (flanking LDLR; p < 2.5 × 10−7) with LDL cholesterol. Common alleles in these genes explained 6.1%–14.7% of the variance in the five lipid-related traits, and individuals at opposite tails of the additive allele score exhibited substantial differences in trait levels (e.g., >1 mmol/L in LDL cholesterol [∼1 SD of the trait distribution]). These data suggest that multiple common alleles of small effect can make important contributions to individual differences in blood lipids potentially relevant to the assessment of CVD risk. These genes provide further insights into lipid metabolism and the likely effects of modifying the encoded targets therapeutically. PMID:19913121

  7. EDC-mediated DNA attachment to nanocrystalline CVD diamond films.

    PubMed

    Christiaens, P; Vermeeren, V; Wenmackers, S; Daenen, M; Haenen, K; Nesládek, M; vandeVen, M; Ameloot, M; Michiels, L; Wagner, P

    2006-08-15

    Chemical vapour deposited (CVD) diamond is a very promising material for biosensor fabrication owing both to its chemical inertness and the ability to make it electrical semiconducting that allows for connection with integrated circuits. For biosensor construction, a biochemical method to immobilize nucleic acids to a diamond surface has been developed. Nanocrystalline diamond is grown using microwave plasma-enhanced chemical vapour deposition (MPECVD). After hydrogenation of the surface, 10-undecenoic acid, an omega-unsaturated fatty acid, is tethered by 254 nm photochemical attachment. This is followed by 1-ethyl-3-[3-dimethylaminopropyl]carbodiimide (EDC)-mediated attachment of amino (NH(2))-modified dsDNA. The functionality of the covalently bound dsDNA molecules is confirmed by fluorescence measurements, PCR and gel electrophoresis during 35 denaturation and rehybridisation steps. The linking method after the fatty acid attachment can easily be applied to other biomolecules like antibodies and enzymes.

  8. Electrically insulating films deposited on V-4%Cr-4%Ti by reactive CVD

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Park, J.H.

    1998-04-01

    In the design of liquid-metal blankets for magnetic fusion reactors, corrosion resistance of structural materials and the magnetohydrodynamic forces and their influence on thermal hydraulics and corrosion are major concerns. Electrically insulating CaO films deposited on V-4%Cr-4%Ti exhibit high-ohmic insulator behavior even though a small amount of vanadium from the alloy become incorporated into the film. However, when vanadium concentration in the film is > 15 wt.%, the film becomes conductive. When the vanadium concentration is high in localized areas, a calcium vanadate phase that exhibits semiconductor behavior can form. The objective of this study is to evaluate electrically insulatingmore » films that were deposited on V-4%Cr-4%Ti by a reactive chemical vapor deposition (CVD) method. To this end, CaO and Ca-V-O coatings were produced on vanadium alloys by CVD and by a metallic-vapor process to investigate the electrical resistance of the coatings. The authors found that the Ca-V-O films exhibited insulator behavior when the ratio of calcium concentration to vanadium concentration R in the film > 0.9, and semiconductor or conductor behavior when R < 0.8. However, in some cases, semiconductor behavior was observed when CaO-coated samples with R > 0.98 were exposed in liquid lithium. Based on these studies, they conclude that semiconductor behavior occurs if a conductive calcium vanadate phase is present in localized regions in the CaO coating.« less

  9. Thermoelectric properties of CVD grown large area graphene

    NASA Astrophysics Data System (ADS)

    Sherehiy, Andriy; Jayasinghe, Ruwantha; Stallard, Robert; Sumanasekera, Gamini; Sidorov, Anton; Benjamin, Daniel; Jiang, Zhigang; Yu, Qingkai; Wu, Wei; Bao, Jiming; Liu, Zhihong; Pei, Steven; Chen, Yong

    2010-03-01

    The thermoelectric power (TEP) of CVD (Chemical Vapor Deposition) grown large area graphene transferred onto a Si/SiO2 substrate was measured by simply attaching two miniature thermocouples and a resistive heater. Availability of such large area graphene facilitates straight forward TEP measurement without the use of any microfabrication processes. All investigated graphene samples showed a positive TEP ˜ + 30 μV/K in ambient conditions and saturated at a negative value as low as ˜ -75 μV/K after vacuum-annealing at 500 K in a vacuum of ˜10-7 Torr. The observed p-type behavior under ambient conditions is attributed to the oxygen doping, while the n-type behavior under degassed conditions is due to electron doping from SiO2 surface states. It was observed that the sign of the TEP switched from negative to positive for the degassed graphene when exposed to acceptor gases. Conversely, the TEP of vacuum-annealed graphene exposed to the donor gases became even more negative than the TEP of vacuum-annealed sample.

  10. Association between dietary fibre intake and fruit, vegetable or whole-grain consumption and the risk of CVD: results from the PREvención con DIeta MEDiterránea (PREDIMED) trial.

    PubMed

    Buil-Cosiales, Pilar; Toledo, Estefania; Salas-Salvadó, Jordi; Zazpe, Itziar; Farràs, Marta; Basterra-Gortari, Francisco Javier; Diez-Espino, Javier; Estruch, Ramon; Corella, Dolores; Ros, Emilio; Marti, Amelia; Gómez-Gracia, Enrique; Ortega-Calvo, Manuel; Arós, Fernando; Moñino, Manuel; Serra-Majem, Lluis; Pintó, Xavier; Lamuela-Raventós, Rosa Maria; Babio, Nancy; Gonzalez, Jose I; Fitó, Montserrat; Martínez-González, Miguel A

    2016-08-01

    Prospective studies assessing the association between fibre intake or fibre-rich food consumption and the risk of CVD have often been limited by baseline assessment of diet. Thus far, no study has used yearly repeated measurements of dietary changes during follow-up. Moreover, previous studies included healthy and selected participants who did not represent subjects at high cardiovascular risk. We used yearly repeated measurements of diet to investigate the association between fibre intake and CVD in a Mediterranean cohort of elderly adults at high cardiovascular risk. We followed-up 7216 men (55-80 years) and women (60-80 years) initially free of CVD for up to 7 years in the PREvención con DIeta MEDiterránea study (registered as ISRCTN35739639). A 137-item validated FFQ was repeated yearly to assess diet. The primary end point, confirmed by a blinded ad hoc Event Adjudication Committee, was a composite of cardiovascular death, myocardial infarction and stroke. Time-dependent Cox's regression models were used to estimate the risk of CVD according to baseline dietary exposures and to their yearly updated changes. We found a significant inverse association for fibre (P for trend=0·020) and fruits (P for trend=0·024) in age-sex adjusted models, but the statistical significance was lost in fully adjusted models. However, we found a significant inverse association with CVD incidence for the sum of fruit and vegetable consumption. Participants who consumed in total nine or more servings/d of fruits plus vegetables had a hazard ratio 0·60 (95 % CI 0·40, 0·96) of CVD in comparison with those consuming <5 servings/d.

  11. A Review of Carbon Nanomaterials' Synthesis via the Chemical Vapor Deposition (CVD) Method.

    PubMed

    Manawi, Yehia M; Samara, Ayman; Al-Ansari, Tareq; Atieh, Muataz A

    2018-05-17

    Carbon nanomaterials have been extensively used in many applications owing to their unique thermal, electrical and mechanical properties. One of the prime challenges is the production of these nanomaterials on a large scale. This review paper summarizes the synthesis of various carbon nanomaterials via the chemical vapor deposition (CVD) method. These carbon nanomaterials include fullerenes, carbon nanotubes (CNTs), carbon nanofibers (CNFs), graphene, carbide-derived carbon (CDC), carbon nano-onion (CNO) and MXenes. Furthermore, current challenges in the synthesis and application of these nanomaterials are highlighted with suggested areas for future research.

  12. A Review of Carbon Nanomaterials’ Synthesis via the Chemical Vapor Deposition (CVD) Method

    PubMed Central

    Manawi, Yehia M.; Samara, Ayman; Al-Ansari, Tareq; Atieh, Muataz A.

    2018-01-01

    Carbon nanomaterials have been extensively used in many applications owing to their unique thermal, electrical and mechanical properties. One of the prime challenges is the production of these nanomaterials on a large scale. This review paper summarizes the synthesis of various carbon nanomaterials via the chemical vapor deposition (CVD) method. These carbon nanomaterials include fullerenes, carbon nanotubes (CNTs), carbon nanofibers (CNFs), graphene, carbide-derived carbon (CDC), carbon nano-onion (CNO) and MXenes. Furthermore, current challenges in the synthesis and application of these nanomaterials are highlighted with suggested areas for future research. PMID:29772760

  13. Advances in the Development of a WCl6 CVD System for Coating UO2 Powders with Tungsten

    NASA Technical Reports Server (NTRS)

    Mireles, Omar R.; Tieman, Alyssa; Broadway, Jeramie; Hickman, Robert

    2013-01-01

    Demonstrated viability and utilization of: a) Fluidized powder bed. b) WCl6 CVD process. c) Coated spherical particles with tungsten. The highly corrosive nature of the WCl6 solid reagent limits material of construction. Indications that identifying optimized process variables with require substantial effort and will likely vary with changes in fuel requirements.

  14. CVD growth of large-area and high-quality HfS2 nanoforest on diverse substrates

    NASA Astrophysics Data System (ADS)

    Zheng, Binjie; Wang, Zegao; Qi, Fei; Wang, Xinqiang; Yu, Bo; Zhang, Wanli; Chen, Yuanfu

    2018-03-01

    Two-dimensional layered transition metal dichalcogenides (TMDs) have attracted burgeoning attention due to their various properties and wide potential applications. As a new TMD, hafnium disulfide (HfS2) is theoretically predicted to have better electrical performance than widely studied MoS2. The experimental researches also confirmed the extraordinary feature in electronics and optoelectronics. However, the maximal device performance may not be achieved due to its own limitation of planar structure and challenge of transfer without contamination. Here, through the chemical vapor deposition (CVD) technique, inch-size HfS2 nanoforest has been directly grown on diverse objective substrates covering insulating, semiconducting and conducting substrates. This direct CVD growth without conventional transfer process avoids contamination and degradation in quality, suggesting its promising and wide applications in high-quality and multifarious devices. It is noted that all the HfS2 nanoforests grown on diverse substrates are constructed with vertically aligned few-layered HfS2 nanosheets with high crystalline quality and edge orientation. Moreover, due to its unique structure, the HfS2 nanoforest owns abundant exposed edge sites and large active surface area, which is essential to apply in high-performance catalyst, sensor, and energy storage or field emitter.

  15. Investigation of tool wear and surface roughness on machining of titanium alloy with MT-CVD cutting tool

    NASA Astrophysics Data System (ADS)

    Maity, Kalipada; Pradhan, Swastik

    2018-04-01

    In this study, machining of titanium alloy (grade 5) is carried out using MT-CVD coated cutting tool. Titanium alloys possess superior strength-to-weight ratio with good corrosion resistance. Most of the industries used titanium alloy for the manufacturing of various types of lightweight components. The parts made from Ti-6Al-4V largely used in aerospace, biomedical, automotive and marine sectors. The conventional machining of this material is very difficult, due to low thermal conductivity and high chemical reactivity properties. To achieve a good surface finish with minimum tool wear of cutting tool, the machining is carried out using MT-CVD coated cutting tool. The experiment is carried out using of Taguchi L27 array layout with three cutting variables and levels. To find out the optimum parametric setting desirability function analysis (DFA) approach is used. The analysis of variance is studied to know the percentage contribution of each cutting variables. The optimum parametric setting results calculated from DFA were validated through the confirmation test.

  16. Immobilization of glucoamylase on ceramic membrane surfaces modified with a new method of treatment utilizing SPCP-CVD.

    PubMed

    Ida; Matsuyama; Yamamoto

    2000-07-01

    Glucoamylase, as a model enzyme, was immobilized on a ceramic membrane modified by surface corona discharge induced plasma chemical process-chemical vapor deposition (SPCP-CVD). Characterizations of the immobilized enzyme were then discussed. Three kinds of ceramic membranes with different amounts of amino groups on the surface were prepared utilizing the SPCP-CVD method. Each with 1-time, 3-times and 5-times surface modification treatments and used for supports in glucoamylase immobilization. The amount of immobilized glucoamylase increased with the increase in the number of surface modification treatments and saturated to a certain maximum value estimated by a two-dimensional random packing. The operational stability of the immobilized glucoamylase also increased with the increase in the number of the surface treatment. It was almost the same as the conventional method, while the activity of immobilized enzyme was higher. The results indicated the possibility of designing the performance of the immobilized enzyme by controlling the amount of amino groups. The above results showed that the completely new surface modification method using SPCP was effective in modifying ceramic membranes for enzyme immobilization.

  17. Ethylene Gas Sensing Properties of Tin Oxide Nanowires Synthesized via CVD Method

    NASA Astrophysics Data System (ADS)

    Akhir, Maisara A. M.; Mohamed, Khairudin; Rezan, Sheikh A.; Arafat, M. M.; Haseeb, A. S. M. A.; Uda, M. N. A.; Nuradibah, M. A.

    2018-03-01

    This paper studies ethylene gas sensing performance of tin oxide (SnO2) nanowires (NWs) as sensing material synthesized using chemical vapor deposition (CVD) technique. The effect of NWs diameter on ethylene gas sensing characteristics were investigated. SnO2 NWs with diameter of ∼40 and ∼240 nm were deposited onto the alumina substrate with printed gold electrodes and tested for sensing characteristic toward ethylene gas. From the finding, the smallest diameter of NWs (42 nm) exhibit fast response and recovery time and higher sensitivity compared to largest diameter of NWs (∼240 nm). Both sensor show good reversibility features for ethylene gas sensor.

  18. Direct synthesis of vertically aligned ZnO nanowires on FTO substrates using a CVD method and the improvement of photovoltaic performance

    PubMed Central

    2012-01-01

    In this work, we report a direct synthesis of vertically aligned ZnO nanowires on fluorine-doped tin oxide-coated substrates using the chemical vapor deposition (CVD) method. ZnO nanowires with a length of more than 30 μm were synthesized, and dye-sensitized solar cells (DSSCs) based on the as-grown nanowires were fabricated, which showed improvement of the device performance compared to those fabricated using transferred ZnO nanowires. Dependence of the cell performance on nanowire length and annealing temperature was also examined. This synthesis method provided a straightforward, one-step CVD process to grow relatively long ZnO nanowires and avoided subsequent nanowire transfer process, which simplified DSSC fabrication and improved cell performance. PMID:22673046

  19. Impedance study of undoped, polycrystalline diamond layers obtained by HF CVD

    NASA Astrophysics Data System (ADS)

    Paprocki, Kazimierz; Fabisiak, Kazimerz; Dychalska, Anna; Szybowicz, Mirosław; Dudkowiak, Alina; Iskaliyeva, Aizhan

    2017-04-01

    In this paper, we report results of impedance measurements in polycrystalline diamond films deposited on n-Si using HF CVD method. The temperature was changed from 170 K up to RT and the scan frequency from 42 Hz to 5 MHz. The results of impedance measurement of the real and imaginary parts were presented in the form of a Cole-Cole plot in the complex plane. In the temperatures below RT, the observed impedance response of polycrystalline diamond was in the form of a single semicircular form. In order to interpret the observed response, a double resistor-capacitor parallel circuit model was used which allow for interpretation physical mechanisms responsible for such behavior. The impedance results were correlated with Raman spectroscopy measurements.

  20. Calculation of residual principal stresses in CVD boron on carbon filaments

    NASA Technical Reports Server (NTRS)

    Behrendt, D. R.

    1980-01-01

    A three-dimensional finite element model of the chemical vapor deposition (CVD) of boron on a carbon substrate (B/C) is developed. The model includes an expansion of the boron after deposition due to atomic rearrangement and includes creep of the boron and carbon. Curves are presented to show how the principal residual stresses and the filament elongation vary as the parameters defining deposition strain and creep are varied. The calculated results are compared with experimental axial residual stress and elongation measurements made on B/C filaments. This comparison requires that for good agreement between calculated and experimental results, the deposited boron must continue to expand after deposition, and that the build-up of residual stresses is limited by significant boron and carbon creep rates.

  1. Treatment with liraglutide may improve markers of CVD reflected by reduced levels of apoB.

    PubMed

    Engelbrechtsen, L; Lundgren, J; Wewer Albrechtsen, N J; Mahendran, Y; Iepsen, E W; Finocchietto, P; Jonsson, A E; Madsbad, S; Holst, J J; Vestergaard, H; Hansen, T; Torekov, S S

    2017-12-01

    Dislipidaemia and increased levels of apolipoprotein B (apoB) in individuals with obesity are risk factors for development of cardiovascular disease (CVD). The aim of this study was to investigate the effect of weight loss and weight maintenance with and without liraglutide treatment on plasma lipid profiles and apoB. Fifty-eight individuals with obesity (body mass index 34.5 ± 3.0 kg/m 2 [mean ± SD]) were included in this study. After 8 weeks on a very low-calorie diet (800 kcal/day), participants were randomized to weight maintenance with meal replacements with or without liraglutide (1.2 mg daily) for 1 year. Plasma samples from before and after weight loss and after 1 year of weight maintenance were subjected to nuclear magnetic resonance-based lipidomics analysis. After an 8-week low-calorie diet, study participants lost 12.0 ± 2.9 kg (mean ± SD) of their body weight, which was reflected in their lipid profiles (80 out of 124 lipids changed significantly), including reduced levels of apoB, total cholesterol, free cholesterol, remnant cholesterol, triglycerides, low-density lipoprotein and very low-density lipoprotein subclasses. After 1 year of maintained weight loss, the majority of the lipids had returned to pre-weight loss levels even though weight loss was successfully maintained in both groups. Interestingly, apoB levels remained low in the liraglutide treated group (apoB change: 0.03 ± 0.02 mmol/L, p = 0.4) in contrast to an increase in the control group (apoB change: 0.06 ± 0.07 mmol/L, p = 0.02). An 8-week low-calorie diet, in individuals with obesity, reduced plasma levels of lipids and the atherogenic marker apoB. After 1 year of weight maintenance, only study participants treated with liraglutide maintained reduced levels of apoB, despite similar body weight maintenance. Treatment with liraglutide may therefore reduce apoB levels and thus reflect lower CVD risk. Including apoB measurements in clinical practice when

  2. Fabrication of all-carbon nanotube electronic devices on flexible substrates through CVD and transfer methods.

    PubMed

    Zou, Yuan; Li, Qunqing; Liu, Junku; Jin, Yuanhao; Qian, Qingkai; Jiang, Kaili; Fan, Shoushan

    2013-11-13

    SWNT thin films with different nanotube densities are fabricated by CVD while controlling the concentration of catalyst and growth time. Three layers of SWNT films are transferred to flexible substrates serving as electrodes and channel materials, respectively. All-carbon nanotube TFTs with an on/off ratio as high as 10(5) are obtained. Inverters are fabricated on top of the flexible substrates with symmetric input/output behavior. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. Effects of Surface Treatments on Secondary Electron Emission from CVD Diamond Films

    NASA Technical Reports Server (NTRS)

    Mearini, G. T.; Krainsky, I. L.; Dayton, J. A., Jr.; Zorman, Christian; Wang, Yaxin; Lamouri, A.

    1995-01-01

    Secondary electron emission (SEE) properties of polycrystalline diamond films grown by chemical vapor deposition (CVD) were measured. The total secondary yield (sigma) from as-grown samples was observed to be as high as 20 at room temperature and 48 while heating at 700 K in vacuum. Electron-beam-activated, alkali-terminated diamond films have shown stable values of sigma as high as 60 when coated with CsI and similarly high values when coated with other alkali halides. Diamond coated with BaF2 had a stable sigma of 6, but no enhancement of the SEE properties was observed with coatings of Ti or Au. Hydrogen was identified to give rise to this effect in as-grown films. However, electron beam exposure led to a reduction in sigma values as low as 2. Exposure to a molecular hydrogen environment restored sigma to its original value after degradation, and enabled stable secondary emission during electron beam exposure. Atomic hydrogen and hydrogen plasma treatments were performed on diamond/Mo samples in an attempt to increase the near-surface hydrogen concentration which might lead to increased stability in the secondary emission. Raman scattering analysis, scanning electron microscopy, and Auger electron spectroscopy (AES) confirmed that hydrogen plasma and atomic hydrogen treatments improved the quality of the CVD diamond significantly. Elastic recoil detection (ERD) showed that heating as-grown diamond targets to 7OO K, which was correlated with an increase in sigma, removed contaminants from the surface but did not drive hydrogen from the diamond bulk. ERD showed that the hydrogen plasma treatment produced an increase in the hydrogen concentration in the near-surface region which did not decrease while heating in vacuum at 700 K, but no improvement in the SEE properties was observed.

  4. Cardiovascular health in adolescents with type 1 diabetes: the SEARCH CVD study.

    PubMed

    Alman, Amy C; Talton, Jennifer W; Wadwa, R Paul; Urbina, Elaine M; Dolan, Lawrence M; Daniels, Stephen R; Hamman, Richard F; D'Agostino, Ralph B; Marcovina, Santica M; Mayer-Davis, Elizabeth J; Dabelea, Dana M

    2014-11-01

    In their Strategic Impact Goal Statement, the American Heart Association focused on primordial prevention of cardiovascular risk factors by defining metrics for ideal cardiovascular health (ICH). The prevalence of ICH among youth with type 1 diabetes is unknown. Youth with type 1 diabetes face an increased risk of cardiovascular disease (CVD) as they age. The purpose of this report was to examine the prevalence of ICH in a population of youth with type 1 diabetes and to examine the association of ICH with measures of cardiovascular structure and function. This report is based on SEARCH CVD an ancillary study to the SEARCH for Diabetes in Youth. A total of 190 adolescents with type 1 diabetes had complete data on all of the ICH metrics at baseline and had measures of arterial stiffness [pulse wave velocity (PWV), brachial distensibility (BrachD), and augmentation index (AIx)] and carotid intima-media thickness completed at a follow-up visit [on average 5 yr after baseline (interquartile range 4-5)]. No subjects met the ICH criteria for all 7 metrics. Meeting an increasing number of ICH metrics was significantly associated with lower arterial stiffness [lower PWV of the trunk (β = -0.02 ±0.01; p = 0.004) and AIx (β = -2.2 ±0.66; p = 0.001), and increased BrachD (β = 0.14 ±0.07; p = 0.04)]. Increasing number of ICH metrics was significantly associated with decreased arterial stiffness, but prevalence of ICH in this population was low. Youth with type 1 diabetes could benefit from improvements in their cardiovascular health. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  5. Fast method for reactor and feature scale coupling in ALD and CVD

    DOEpatents

    Yanguas-Gil, Angel; Elam, Jeffrey W.

    2017-08-08

    Transport and surface chemistry of certain deposition techniques is modeled. Methods provide a model of the transport inside nanostructures as a single-particle discrete Markov chain process. This approach decouples the complexity of the surface chemistry from the transport model, thus allowing its application under general surface chemistry conditions, including atomic layer deposition (ALD) and chemical vapor deposition (CVD). Methods provide for determination of determine statistical information of the trajectory of individual molecules, such as the average interaction time or the number of wall collisions for molecules entering the nanostructures as well as to track the relative contributions to thin-film growth of different independent reaction pathways at each point of the feature.

  6. The CVD ZrB2 as a selective solar absorber

    NASA Astrophysics Data System (ADS)

    Randich, E.; Allred, D. D.

    Coatings of ZrB2 and TiB2 for photothermal solar absorber applications were prepared using chemical vapor deposition (CVD) techniques. Oxidation tests suggest a maximum temperature limit for air exposure of 600 K for TiB2 and 800 K for Z4B2. Both materials exhibit innate spectral selectivity with emittance at 375 K ranging from 0.06 to 0.09 and solar absorptance for ZrB2 ranging from 0.67 to 0.77 and solar absorptance for TiB2 ranging from 0.46 to 0.58. ZrB2 has better solar selectivity and more desirable oxidation behavior than TiB2. A 0.071 micrometer antireflection coating of Si3N4 deposited on the ZrB2 coating leads to an increase in absorptance from 0.77 to 0.93, while the emittance remains unchanged.

  7. HRCT findings of collagen vascular disease-related interstitial pneumonia (CVD-IP): a comparative study among individual underlying diseases.

    PubMed

    Tanaka, N; Kunihiro, Y; Kubo, M; Kawano, R; Oishi, K; Ueda, K; Gondo, T

    2018-05-29

    To identify characteristic high-resolution computed tomography (CT) findings for individual collagen vascular disease (CVD)-related interstitial pneumonias (IPs). The HRCT findings of 187 patients with CVD, including 55 patients with rheumatoid arthritis (RA), 50 with systemic sclerosis (SSc), 46 with polymyositis/dermatomyositis (PM/DM), 15 with mixed connective tissue disease, 11 with primary Sjögren's syndrome, and 10 with systemic lupus erythematosus, were evaluated. Lung parenchymal abnormalities were compared among CVDs using χ 2 test, Kruskal-Wallis test, and multiple logistic regression analysis. A CT-pathology correlation was performed in 23 patients. In RA-IP, honeycombing was identified as the significant indicator based on multiple logistic regression analyses. Traction bronchiectasis (81.8%) was further identified as the most frequent finding based on χ 2 test. In SSc IP, lymph node enlargement and oesophageal dilatation were identified as the indicators based on multiple logistic regression analyses, and ground-glass opacity (GGO) was the most extensive based on Kruskal-Wallis test, which reflects the higher frequency of the pathological nonspecific interstitial pneumonia (NSIP) pattern present in the CT-pathology correlation. In PM/DM IP, airspace consolidation and the absence of honeycombing were identified as the indicators based on multiple logistic regression analyses, and predominance of consolidation over GGO (32.6%) and predominant subpleural distribution of GGO/consolidation (41.3%) were further identified as the most frequent findings based on χ 2 test, which reflects the higher frequency of the pathological NSIP and/or the organising pneumonia patterns present in the CT-pathology correlation. Several characteristic high-resolution CT findings with utility for estimating underlying CVD were identified. Copyright © 2018 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  8. Ultrasonic cavity preparation using CVD coated diamond bur: A case report

    PubMed Central

    de Vasconcellos, Beatriz Tholt; Thompson, Jeffrey Y.; de Paula Macedo, Manoel Roberto; de Oliveira Maia, Janaína Monalisa; Oda, Margareth; Garone-Netto, Narciso

    2013-01-01

    Before any restorative procedure can be undertaken a proper cavity preparation is required. This clinical step is the mechanical alteration of the tooth to receive a restorative material with which a satisfactory form, function and the esthetics of the tooth will be established. In recent years improvements in materials and techniques have been devised and new technologies are now available for this purpose. The aim of the present study is to report two clinical cases in which a CVD coated diamond bur coupled to an ultrasonic handpiece is used in dental preparation. This technique provides an accurate and conservative tooth preparation with ideal access and visibility and because of enhanced efficiency can also play a role in eliminating some of the patient discomfort of the dental treatment. PMID:23408140

  9. CVD Fiber Coatings for Al2O3/NiAl Composites

    NASA Technical Reports Server (NTRS)

    Boss, Daniel E.

    1995-01-01

    While sapphire-fiber-reinforced nickel aluminide (Al2O3/NiAl) composites are an attractive candidate for high-temperature structures, the significant difference in the coefficient of thermal expansion between the NiAl matrix and the sapphire fiber creates substantial residual stresses in the composite. This study seeks to produce two fiber-coating systems with the potential to reduce the residual stresses in the sapphire/NiAl composite system. Chemical vapor deposition (CVD) was used to produce both the compensating and compliant-fiber coatings for use in sapphire/NiAl composites. A special reactor was designed and built to produce the FGM and to handle the toxic nickel precursors. This process was successfully used to produce 500-foot lengths of fiber with coating thicknesses of approximately 3 microns, 5 microns, and 10 microns.

  10. Effect of irradiation with MeV protons and electrons on the conductivity compensation and photoluminescence of moderately doped p-4H-SiC (CVD)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kozlovski, V. V.; Lebedev, A. A., E-mail: shura.lebe@mail.ioffe.ru; Bogdanova, E. V.

    The compensation of moderately doped p-4H-SiC samples grown by the chemical vapor deposition (CVD) method under irradiation with 0.9-MeV electrons and 15-MeV protons is studied. The experimentally measured carrier removal rates are 1.2–1.6 cm{sup –1} for electrons and 240–260 cm{sup –1} for protons. The dependence of the concentration of uncompensated acceptors and donors, measured in the study, demonstrates a linear decrease with increasing irradiation dose to the point of complete compensation. This run of the dependence shows that compensation of the samples is due to the transition of carriers to deep centers formed by primary radiation-induced defects. It is demonstratedmore » that, in contrast to n-SiC (CVD), primary defects in the carbon sublattice of moderately doped p-SiC (CVD) only cannot account for the compensation process. In p-SiC, either primary defects in the silicon sublattice, or defects in both sublattices are responsible for conductivity compensation. Also, photoluminescence spectra are examined in relation to the irradiation dose.« less

  11. Pushing the boundaries of high power lasers: low loss, large area CVD diamond

    NASA Astrophysics Data System (ADS)

    Wickham, Benjamin; Schoofs, Frank; Olsson-Robbie, Stefan; Bennett, Andrew; Balmer, Richard

    2018-02-01

    Synthetic CVD diamond has exceptional properties, including broad spectral transmission, physical and chemical robustness, and the highest thermal conductivity of any known material, making diamond an attractive material for medium to high power optical and laser applications, minimizing the detrimental effects of thermal lensing and radiation damage. Example applications include ATR prisms, Raman laser crystals, extra- and intra-cavity laser cooling. In each case the demands on the fundamental material properties and fabrication routes are slightly different. In recent years, there has been good progress in the development of low-loss, single crystal diamond, suitable for higher power densities, higher pulse rates and more demanding intra- and extra-cavity thermal management. The adoption of single crystal diamond in this area has however, been hindered by the availability of large area, low birefringence plates. To address this, we report a combination of CVD growth and processing methods that have enabled the manufacture of large, low defect substrates. A final homoepitaxial, low absorption synthesis stage has produced plates with large area (up to 16 mm edge length), low absorption (α<0.005 cm-1 at 1064 nm), and low birefringence (Δn <10-5), suitable for double-sided intra-cavity cooling. We demonstrate the practical advances in synthesis, including increasing the size while reducing in-use losses compared to previous generations of single crystal material, and practical developments in processing and implementation of the single crystal diamond parts, optimizing them for use in a state-of-the-art femto-second pulsed Ti:Sa thin disk gain module, all made in collaboration with the wider European FP7 funded Ti:Sa TD consortium.

  12. CVD-associated non-coding RNA, ANRIL, modulates expression of atherogenic pathways in VSMC

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Congrains, Ada; Kamide, Kei; Katsuya, Tomohiro

    Highlights: Black-Right-Pointing-Pointer ANRIL maps in the strongest susceptibility locus for cardiovascular disease. Black-Right-Pointing-Pointer Silencing of ANRIL leads to altered expression of tissue remodeling-related genes. Black-Right-Pointing-Pointer The effects of ANRIL on gene expression are splicing variant specific. Black-Right-Pointing-Pointer ANRIL affects progression of cardiovascular disease by regulating proliferation and apoptosis pathways. -- Abstract: ANRIL is a newly discovered non-coding RNA lying on the strongest genetic susceptibility locus for cardiovascular disease (CVD) in the chromosome 9p21 region. Genome-wide association studies have been linking polymorphisms in this locus with CVD and several other major diseases such as diabetes and cancer. The role of thismore » non-coding RNA in atherosclerosis progression is still poorly understood. In this study, we investigated the implication of ANRIL in the modulation of gene sets directly involved in atherosclerosis. We designed and tested siRNA sequences to selectively target two exons (exon 1 and exon 19) of the transcript and successfully knocked down expression of ANRIL in human aortic vascular smooth muscle cells (HuAoVSMC). We used a pathway-focused RT-PCR array to profile gene expression changes caused by ANRIL knock down. Notably, the genes affected by each of the siRNAs were different, suggesting that different splicing variants of ANRIL might have distinct roles in cell physiology. Our results suggest that ANRIL splicing variants play a role in coordinating tissue remodeling, by modulating the expression of genes involved in cell proliferation, apoptosis, extra-cellular matrix remodeling and inflammatory response to finally impact in the risk of cardiovascular disease and other pathologies.« less

  13. Investigation of laser ablation of CVD diamond film

    NASA Astrophysics Data System (ADS)

    Chao, Choung-Lii; Chou, W. C.; Ma, Kung-Jen; Chen, Ta-Tung; Liu, Y. M.; Kuo, Y. S.; Chen, Ying-Tung

    2005-04-01

    Diamond, having many advanced physical and mechanical properties, is one of the most important materials used in the mechanical, telecommunication and optoelectronic industry. However, high hardness value and extreme brittleness have made diamond extremely difficult to be machined by conventional mechanical grinding and polishing. In the present study, the microwave CVD method was employed to produce epitaxial diamond films on silicon single crystal. Laser ablation experiments were then conducted on the obtained diamond films. The underlying material removal mechanisms, microstructure of the machined surface and related machining conditions were also investigated. It was found that during the laser ablation, peaks of the diamond grains were removed mainly by the photo-thermal effects introduced by excimer laser. The diamond structures of the protruded diamond grains were transformed by the laser photonic energy into graphite, amorphous diamond and amorphous carbon which were removed by the subsequent laser shots. As the protruding peaks gradually removed from the surface the removal rate decreased. Surface roughness (Ra) was improved from above 1μm to around 0.1μm in few minutes time in this study. However, a scanning technique would be required if a large area was to be polished by laser and, as a consequence, it could be very time consuming.

  14. Influence of low energy argon plasma treatment on the moisture barrier performance of hot wire-CVD grown SiNx multilayers

    NASA Astrophysics Data System (ADS)

    Majee, Subimal; Fátima Cerqueira, Maria; Tondelier, Denis; Geffroy, Bernard; Bonnassieux, Yvan; Alpuim, Pedro; Bourée, Jean Eric

    2014-01-01

    The reliability and stability are key issues for the commercial utilization of organic photovoltaic devices based on flexible polymer substrates. To increase the shelf-lifetime of these devices, transparent moisture barriers of silicon nitride (SiNx) films are deposited at low temperature by hot wire CVD (HW-CVD) process. Instead of the conventional route based on organic/inorganic hybrid structures, this work defines a new route consisting in depositing multilayer stacks of SiNx thin films, each single layer being treated by argon plasma. The plasma treatment allows creating smoother surface and surface atom rearrangement. We define a critical thickness of the single layer film and focus our attention on the effect of increasing the number of SiNx single-layers on the barrier properties. A water vapor transmission rate (WVTR) of 2 × 10-4 g/(m2·day) is reported for SiNx multilayer stack and a physical interpretation of the plasma treatment effect is given.

  15. Chronic Ingestion of Flavan-3-ols and Isoflavones Improves Insulin Sensitivity and Lipoprotein Status and Attenuates Estimated 10-Year CVD Risk in Medicated Postmenopausal Women With Type 2 Diabetes

    PubMed Central

    Curtis, Peter J.; Sampson, Mike; Potter, John; Dhatariya, Ketan; Kroon, Paul A.; Cassidy, Aedín

    2012-01-01

    OBJECTIVE To assess the effect of dietary flavonoids on cardiovascular disease (CVD) risk in postmenopausal women with type 2 diabetes on established statin and hypoglycemic therapy. RESEARCH DESIGN AND METHODS Despite being medicated, patients with type 2 diabetes have elevated CVD risk, particularly postmenopausal women. Although dietary flavonoids have been shown to reduce CVD risk factors in healthy participants, no long-term trials have examined the additional benefits of flavonoids to CVD risk in medicated postmenopausal women with type 2 diabetes. We conducted a parallel-design, placebo-controlled trial with type 2 diabetic patients randomized to consume 27 g/day (split dose) flavonoid-enriched chocolate (containing 850 mg flavan-3-ols [90 mg epicatechin] and 100 mg isoflavones [aglycone equivalents)]/day) or matched placebo for 1 year. RESULTS Ninety-three patients completed the trial, and adherence was high (flavonoid 91.3%; placebo 91.6%). Compared with the placebo group, the combined flavonoid intervention resulted in a significant reduction in estimated peripheral insulin resistance (homeostasis model assessment of insulin resistance [HOMA-IR] −0.3 ± 0.2; P = 0.004) and improvement in insulin sensitivity (quantitative insulin sensitivity index [QUICKI] 0.003 ± 0.00; P = 0.04) as a result of a significant decrease in insulin levels (−0.8 ± 0.5 mU/L; P = 0.02). Significant reductions in total cholesterol:HDL-cholesterol (HDL-C) ratio (−0.2 ± 0.1; P = 0.01) and LDL-cholesterol (LDL-C) (−0.1 ± 0.1 mmol/L; P = 0.04) were also observed. Estimated 10-year total coronary heart disease risk (derived from UK Prospective Diabetes Study algorithm) was attenuated after flavonoid intervention (flavonoid +0.1 ± 0.3 vs. placebo 1.1 ± 0.3; P = 0.02). No effect on blood pressure, HbA1c, or glucose was observed. CONCLUSIONS One-year intervention with flavan-3-ols and isoflavones improved biomarkers of CVD risk, highlighting the additional benefit of

  16. Sex specific differences in the predictive value of cholesterol homeostasis markers and 10-Year CVD event rate in Framingham Offspring Study participants

    USDA-ARS?s Scientific Manuscript database

    Available data are inconsistent on factors influencing plasma cholesterol homeostasis marker concentrations and their value in predicting subsequent cardiovascular disease (CVD) events. To address this issue the relationship between markers of cholesterol absorption (campesterol, sitosterol, cholest...

  17. Treatment with liraglutide may improve markers of CVD reflected by reduced levels of apoB

    PubMed Central

    Engelbrechtsen, L.; Lundgren, J.; Wewer Albrechtsen, N. J.; Mahendran, Y.; Iepsen, E. W.; Finocchietto, P.; Jonsson, A. E.; Madsbad, S.; Holst, J. J.; Vestergaard, H.; Hansen, T.

    2017-01-01

    Summary Background Dislipidaemia and increased levels of apolipoprotein B (apoB) in individuals with obesity are risk factors for development of cardiovascular disease (CVD). The aim of this study was to investigate the effect of weight loss and weight maintenance with and without liraglutide treatment on plasma lipid profiles and apoB. Methods Fifty‐eight individuals with obesity (body mass index 34.5 ± 3.0 kg/m2 [mean ± SD]) were included in this study. After 8 weeks on a very low‐calorie diet (800 kcal/day), participants were randomized to weight maintenance with meal replacements with or without liraglutide (1.2 mg daily) for 1 year. Plasma samples from before and after weight loss and after 1 year of weight maintenance were subjected to nuclear magnetic resonance‐based lipidomics analysis. Results After an 8‐week low‐calorie diet, study participants lost 12.0 ± 2.9 kg (mean ± SD) of their body weight, which was reflected in their lipid profiles (80 out of 124 lipids changed significantly), including reduced levels of apoB, total cholesterol, free cholesterol, remnant cholesterol, triglycerides, low‐density lipoprotein and very low‐density lipoprotein subclasses. After 1 year of maintained weight loss, the majority of the lipids had returned to pre‐weight loss levels even though weight loss was successfully maintained in both groups. Interestingly, apoB levels remained low in the liraglutide treated group (apoB change: 0.03 ± 0.02 mmol/L, p = 0.4) in contrast to an increase in the control group (apoB change: 0.06 ± 0.07 mmol/L, p = 0.02). Conclusion An 8‐week low‐calorie diet, in individuals with obesity, reduced plasma levels of lipids and the atherogenic marker apoB. After 1 year of weight maintenance, only study participants treated with liraglutide maintained reduced levels of apoB, despite similar body weight maintenance. Treatment with liraglutide may therefore reduce apoB levels and thus reflect lower

  18. LASER APPLICATIONS AND OTHER TOPICS IN QUANTUM ELECTRONICS: Measurement of optical absorption in polycrystalline CVD diamond plates by the phase photothermal method at a wavelength of 10.6 μm

    NASA Astrophysics Data System (ADS)

    Luk'yanov, A. Yu; Ral'chenko, Viktor G.; Khomich, A. V.; Serdtsev, E. V.; Volkov, P. V.; Savel'ev, A. V.; Konov, Vitalii I.

    2008-12-01

    A highly-efficient phase photothermal method is developed for quantitative measurements of the small optical absorption coefficient in thin plates made of highly transparent materials in which bulk losses significantly exceed surface losses. The bulk absorption coefficient at 10.6 μm is estimated in polycrystalline diamond plates grown from the vapour phase (a CVD diamond). The results are compared with those for natural and synthetic diamond single crystals and with the concentrations of nitrogen and hydrogen impurities. The absorption coefficient of the best samples of the CVD diamond did not exceed 0.06 cm-1, which, taking into account the high thermal conductivity of the CVD diamond (1800-2200 W mK-1 at room temperature), makes this material attractive for fabricating output windows of high-power CO2 lasers, especially for manufacturing large-size optics.

  19. Charge transfer effects, thermo and photochromism in single crystal CVD synthetic diamond.

    PubMed

    Khan, R U A; Martineau, P M; Cann, B L; Newton, M E; Twitchen, D J

    2009-09-09

    We report on the effects of thermal treatment and ultraviolet irradiation on the point defect concentrations and optical absorption profiles of single crystal CVD synthetic diamond. All thermal treatments were below 850 K, which is lower than the growth temperature and unlikely to result in any structural change. UV-visible absorption spectroscopy measurements showed that upon thermal treatment (823 K), various broad absorption features diminished: an absorption band at 270 nm (used to deduce neutral single substitutional nitrogen (N(S)(0)) concentrations) and also two broad features centred at approximately 360 and 520 nm. Point defect centre concentrations as a function of temperature were also deduced using electron paramagnetic resonance (EPR) spectroscopy. Above ∼500 K, we observed a decrease in the concentration of N(S)(0) centres and a concomitant increase in the negatively charged nitrogen-vacancy-hydrogen (NVH) complex (NVH(-)) concentration. Both transitions exhibited an activation energy between 0.6 and 1.2 eV, which is lower than that for the N(S)(0) donor (∼1.7 eV). Finally, it was found that illuminating samples with intense short-wave ultraviolet light recovered the N(S)(0) concentration and also the 270, 360 and 520 nm absorption features. From these results, we postulate a valence band mediated charge transfer process between NVH and single nitrogen centres with an acceptor trap depth for NVH of 0.6-1.2 eV. Because the loss of N(S)(0) concentration is greater than the increase in NVH(-) concentration we also suggest the presence of another unknown acceptor existing at a similar energy to NVH. The extent to which the colour in CVD synthetic diamond is dependent on prior history is discussed.

  20. Diabetes and CVD risk during angiotensin-converting enzyme inhibitor or angiotensin II receptor blocker treatment in hypertension: a study of 15,990 patients.

    PubMed

    Hasvold, L P; Bodegård, J; Thuresson, M; Stålhammar, J; Hammar, N; Sundström, J; Russell, D; Kjeldsen, S E

    2014-11-01

    Differences in clinical effectiveness between angiotensin-converting enzyme inhibitors (ACEis) and angiotensin receptor blockers (ARBs) in the primary treatment of hypertension are unknown. The aim of this retrospective cohort study was to assess the prevention of type 2 diabetes and cardiovascular disease (CVD) in patients treated with ARBs or ACEis. Patients initiated on enalapril or candesartan treatment in 71 Swedish primary care centers between 1999 and 2007 were included. Medical records data were extracted and linked with nationwide hospital discharge and cause of death registers. The 11,725 patients initiated on enalapril and 4265 on candesartan had similar baseline characteristics. During a mean follow-up of 1.84 years, 36,482 patient-years, the risk of new diabetes onset was lower in the candesartan group (hazard ratio (HR) 0.81, 95% confidence interval (CI) 0.69-0.96, P=0.01) compared with the enalapril group. No difference between the groups was observed in CVD risk (HR 0.99, 95% CI 0.87-1.13, P=0.86). More patients discontinued treatment in the enalapril group (38.1%) vs the candesartan group (27.2%). In a clinical setting, patients initiated on candesartan treatment had a lower risk of new-onset type 2 diabetes and lower rates of drug discontinuation compared with patients initiated on enalapril. No differences in CVD risk were observed.

  1. Controlled growth of CNT in mesoporous AAO through optimized conditions for membrane preparation and CVD operation

    NASA Astrophysics Data System (ADS)

    Ciambelli, P.; Arurault, L.; Sarno, M.; Fontorbes, S.; Leone, C.; Datas, L.; Sannino, D.; Lenormand, P.; Le Blond Du Plouy, S.

    2011-07-01

    Anodic aluminium oxide (RAAO) membranes with a mesoporous structure were prepared under strictly controlling experimental process conditions, and physically and chemically characterized by a wide range of experimental techniques. Commercial anodic aluminium oxide (CAAO) membranes were also investigated for comparison. We demonstrated that RAAO membranes have lower content of both water and phosphorus and showed better porosity shape than CAAO. The RAAO membranes were used for template growth of carbon nanotubes (CNT) inside its pores by ethylene chemical vapour deposition (CVD) in the absence of a catalyst. A composite material, containing one nanotube for each channel, having the same length as the membrane thickness and an external diameter close to the diameter of the membrane holes, was obtained. Yield, selectivity and quality of CNTs in terms of diameter, length and arrangement (i.e. number of tubes for each channel) were optimized by investigating the effect of changing the experimental conditions for the CVD process. We showed that upon thermal treatment RAAO membranes were made up of crystallized allotropic alumina phases, which govern the subsequent CNT growth, because of their catalytic activity, likely due to their Lewis acidity. The strict control of experimental conditions for membrane preparation and CNT growth allowed us to enhance the carbon structural order, which is a critical requisite for CNT application as a substitute for copper in novel nano-interconnects.

  2. Controlled growth of CNT in mesoporous AAO through optimized conditions for membrane preparation and CVD operation.

    PubMed

    Ciambelli, P; Arurault, L; Sarno, M; Fontorbes, S; Leone, C; Datas, L; Sannino, D; Lenormand, P; Du Plouy, S Le Blond

    2011-07-01

    Anodic aluminium oxide (RAAO) membranes with a mesoporous structure were prepared under strictly controlling experimental process conditions, and physically and chemically characterized by a wide range of experimental techniques. Commercial anodic aluminium oxide (CAAO) membranes were also investigated for comparison. We demonstrated that RAAO membranes have lower content of both water and phosphorus and showed better porosity shape than CAAO. The RAAO membranes were used for template growth of carbon nanotubes (CNT) inside its pores by ethylene chemical vapour deposition (CVD) in the absence of a catalyst. A composite material, containing one nanotube for each channel, having the same length as the membrane thickness and an external diameter close to the diameter of the membrane holes, was obtained. Yield, selectivity and quality of CNTs in terms of diameter, length and arrangement (i.e. number of tubes for each channel) were optimized by investigating the effect of changing the experimental conditions for the CVD process. We showed that upon thermal treatment RAAO membranes were made up of crystallized allotropic alumina phases, which govern the subsequent CNT growth, because of their catalytic activity, likely due to their Lewis acidity. The strict control of experimental conditions for membrane preparation and CNT growth allowed us to enhance the carbon structural order, which is a critical requisite for CNT application as a substitute for copper in novel nano-interconnects.

  3. TaC-coated graphite prepared via a wet ceramic process: Application to CVD susceptors for epitaxial growth of wide-bandgap semiconductors

    NASA Astrophysics Data System (ADS)

    Nakamura, Daisuke; Kimura, Taishi; Narita, Tetsuo; Suzumura, Akitoshi; Kimoto, Tsunenobu; Nakashima, Kenji

    2017-11-01

    A novel sintered tantalum carbide coating (SinTaC) prepared via a wet ceramic process is proposed as an approach to reducing the production cost and improving the crystal quality of bulk-grown crystals and epitaxially grown films of wide-bandgap semiconductors. Here, we verify the applicability of the SinTaC components as susceptors for chemical vapor deposition (CVD)-SiC and metal-organic chemical vapor deposition (MOCVD)-GaN epitaxial growth in terms of impurity incorporation from the SinTaC layers and also clarify the surface-roughness controllability of SinTaC layers and its advantage in CVD applications. The residual impurity elements in the SinTaC layers were confirmed to not severely incorporate into the CVD-SiC and MOCVD-GaN epilayers grown using the SinTaC susceptors. The quality of the epilayers was also confirmed to be equivalent to that of epilayers grown using conventional susceptors. Furthermore, the surface roughness of the SinTaC components was controllable over a wide range of average roughness (0.4 ≤ Ra ≤ 5 μm) and maximum height roughness (3 ≤ Rz ≤ 36 μm) through simple additional surface treatment procedures, and the surface-roughened SinTaC susceptor fabricated using these procedures was predicted to effectively reduce thermal stress on epi-wafers. These results confirm that SinTaC susceptors are applicable to epitaxial growth processes and are advantageous over conventional susceptor materials for reducing the epi-cost and improving the quality of epi-wafers.

  4. The interaction of fatigue, physical activity, and health-related quality of life in adults with multiple sclerosis (MS) and cardiovascular disease (CVD).

    PubMed

    Newland, Pamela K; Lunsford, Valerie; Flach, Alicia

    2017-02-01

    In addition to the underlying health problems and disability associated with multiple sclerosis (MS) and cardiovascular disease (CVD), adults with each of these chronic illnesses are independently known to experience fatigue. While fatigue's influence on physical activity and health related quality of life (HRQOL) with each of these illnesses has been discussed, what is lacking is information on how fatigue impacts physical activity and health related quality of life, and ultimately self-management for adults with these conditions. Additionally, individuals may be unaware of the significance of maintaining optimal physical activity in order to maintain everyday function and self-management. Thus, the purpose of this article is to discuss the complex effect of fatigue on physical activity and HRQOL among adults with MS and CVD, and to present potential self-management strategies. Copyright © 2016 Elsevier Inc. All rights reserved.

  5. Low temperature growth of diamond films on optical fibers using Linear Antenna CVD system

    NASA Astrophysics Data System (ADS)

    Ficek, M.; Drijkoningen, S.; Karczewski, J.; Bogdanowicz, R.; Haenen, K.

    2016-01-01

    It is not trivial to achieve a good quality diamond-coated fibre interface due to a large difference in the properties and composition of the diamond films (or use coating even) and the optical fibre material, i.e. fused silica. One of the biggest problems is the high temperature during the deposition which influences the optical fibre or optical fibre sensor structure (e.g. long-period gratings (LPG)). The greatest advantage of a linear antenna microwave plasma enhanced chemical vapor deposition system (LA MW CVD) is the fact that it allows to grow the diamond layers at low temperature (below 300°C) [1]. High quality nanocrystalline diamond (NCD) thin films with thicknesses ranging from 70 nm to 150 nm, were deposited on silicon, glass and optical fibre substrates [2]. Substrates pretreatment by dip-coating and spin coating process with a dispersion consisting of detonation nanodiamond (DND) in dimethyl sulfoxide (DMSO) with polyvinyl alcohol (PVA) has been applied. During the deposition process the continuous mode of operation of the LA MW CVD system was used, which produces a continuous wave at a maximum power of 1.9 kW (in each antenna). Diamond films on optical fibres were obtained at temperatures below 350°C, providing a clear improvement of results compared to our earlier work [3]. The samples were characterized by scanning electron microscopy (SEM) imaging to investigate the morphology of the nanocrystalline diamond films. The film growth rate, film thickness, and optical properties in the VIS-NIR range, i.e. refractive index and extinction coefficient will be discussed based on measurements on reference quartz plates by using spectroscopic ellipsometry (SE).

  6. Prediction of the properties of PVD/CVD coatings with the use of FEM analysis

    NASA Astrophysics Data System (ADS)

    Śliwa, Agata; Mikuła, Jarosław; Gołombek, Klaudiusz; Tański, Tomasz; Kwaśny, Waldemar; Bonek, Mirosław; Brytan, Zbigniew

    2016-12-01

    The aim of this paper is to present the results of the prediction of the properties of PVD/CVD coatings with the use of finite element method (FEM) analysis. The possibility of employing the FEM in the evaluation of stress distribution in multilayer Ti/Ti(C,N)/CrN, Ti/Ti(C,N)/(Ti,Al)N, Ti/(Ti,Si)N/(Ti,Si)N, and Ti/DLC/DLC coatings by taking into account their deposition conditions on magnesium alloys has been discussed in the paper. The difference in internal stresses in the zone between the coating and the substrate is caused by, first of all, the difference between the mechanical and thermal properties of the substrate and the coating, and also by the structural changes that occur in these materials during the fabrication process, especially during the cooling process following PVD and CVD treatment. The experimental values of stresses were determined based on X-ray diffraction patterns that correspond to the modelled values, which in turn can be used to confirm the correctness of the accepted mathematical model for testing the problem. An FEM model was established for the purpose of building a computer simulation of the internal stresses in the coatings. The accuracy of the FEM model was verified by comparing the results of the computer simulation of the stresses with experimental results. A computer simulation of the stresses was carried out in the ANSYS environment using the FEM method. Structure observations, chemical composition measurements, and mechanical property characterisations of the investigated materials has been carried out to give a background for the discussion of the results that were recorded during the modelling process.

  7. Carbon Nanotubes Growth by CVD on Graphite Fibers

    NASA Technical Reports Server (NTRS)

    Zhu, Shen; Su, Ching-Hua; Cochrane, J. C.; Lehoczky, S. L.; Muntele, I.; Ila, D.; Curreri, Peter A. (Technical Monitor)

    2002-01-01

    Due to the superior electrical and mechanical properties of carbon nanotubes (CNT), synthesizing CNT on various substances for electronics devices and reinforced composites have been engaged in many efforts for applications. This presentation will illustrate CNT synthesized on graphite fibers by thermal CVD. On the fiber surface, iron nanoparticles as catalysts for CNT growth are coated. The growth temperature ranges from 600 to 1000 C and the pressure ranges from 100 Torr to one atmosphere. Methane and hydrogen gases with methane content of 10% to 100% are used for the CNT synthesis. At high growth temperatures (greater than or equal to 900 C), the rapid inter-diffusion of the transition metal iron on the graphite surface results in the rough fiber surface without any CNT grown on it. When the growth temperature is relative low (650-800 C), CNT with catalytic particles on the nanotube top ends are fabricated on the graphite surface. (Methane and hydrogen gases with methane content of 10% to 100% are used for the CNT synthesis.) (By measuring the samples) Using micro Raman spectroscopy in the breath mode region, single-walled or multi-walled CNT (MWCNT), depending on growth concentrations, are found. Morphology, length and diameter of these MWCNT are determined by scanning electron microscopy and Raman spectroscopy. The detailed results of syntheses and characterizations will be discussed in the presentation.

  8. A cost-benefit analysis of programmatic use of CVD 103-HgR live oral cholera vaccine in a high-risk population.

    PubMed

    Cookson, S T; Stamboulian, D; Demonte, J; Quero, L; Martinez de Arquiza, C; Aleman, A; Lepetic, A; Levine, M M

    1997-02-01

    Cholera spread to Latin America in 1991; subsequently, cholera vaccination was considered as an interim intervention until long-term solutions involving improved water supplies and sanitation could be introduced. Three successive summer cholera outbreaks in northern Argentina and the licensing of the new single-dose oral cholera vaccine, CVD 103-HgR, raised questions of the cost and benefit of using this new vaccine. This study explored the potential benefits to the Argentine Ministry of Health of treatment costs averted, versus the costs of vaccination with CVD 103-HgR in the relatively confined population of northern Argentina affected by the cholera outbreaks. Water supplies and sanitation in this area are poor but a credible infrastructure for vaccine delivery exists. In our cost-benefit model of a 3-year period (1992-1994) with an annual incidence of 2.5 case-patients per 1000 population and assumptions of vaccine efficacy of 75% and coverage of 75%, vaccination of targeted high risk groups would prevent 1265 cases. Assuming a cost of US$602 per treated case and of US$1.50 per dose of vaccine, the total discounted savings from use of vaccine in the targeted groups would be US$132,100. The projected savings would be altered less by vaccine coverage (range 75-90%) or efficacy (60-85%) changes than by disease incidence changes. Our analysis underestimated the true costs of cholera in Argentina because we included only medical expenditures; Indirect losses to trade and tourism had the greatest economic impact. However, vaccination with CVD 103-HgR was still cost-beneficial in the base case.

  9. Effects of isoflavone-containing soya protein on ex vivo cholesterol efflux, vascular function and blood markers of CVD risk in adults with moderately elevated blood pressure: a dose-response randomised controlled trial.

    PubMed

    Richter, Chesney K; Skulas-Ray, Ann C; Fleming, Jennifer A; Link, Christina J; Mukherjea, Ratna; Krul, Elaine S; Kris-Etherton, Penny M

    2017-05-01

    Emerging CVD risk factors (e.g. HDL function and central haemodynamics) may account for residual CVD risk experienced by individuals who meet LDL-cholesterol and blood pressure (BP) targets. Recent evidence suggests that these emerging risk factors can be modified by polyphenol-rich interventions such as soya, but additional research is needed. This study was designed to investigate the effects of an isoflavone-containing soya protein isolate (delivering 25 and 50 g/d soya protein) on HDL function (i.e. ex vivo cholesterol efflux), macrovascular function and blood markers of CVD risk. Middle-aged adults (n 20; mean age=51·6 (sem 6·6) years) with moderately elevated brachial BP (mean systolic BP=129 (sem 9) mmHg; mean diastolic BP=82·5 (sem 8·4) mmHg) consumed 0 (control), 25 and 50 g/d soya protein in a randomised cross-over design. Soya and control powders were consumed for 6 weeks each with a 2-week compliance break between treatment periods. Blood samples and vascular function measures were obtained at baseline and following each supplementation period. Supplementation with 50 g/d soya protein significantly reduced brachial diastolic BP (-2·3 mmHg) compared with 25 g/d soya protein (Tukey-adjusted P=0·03) but not the control. Soya supplementation did not improve ex vivo cholesterol efflux, macrovascular function or other blood markers of CVD risk compared with the carbohydrate-matched control. Additional research is needed to clarify whether effects on these CVD risk factors depend on the relative health of participants and/or equol producing capacity.

  10. Characteristics of epitaxial garnets grown by CVD using single metal alloy sources. [Chemical Vapor Deposition

    NASA Technical Reports Server (NTRS)

    Besser, P. J.; Hamilton, T. N.; Mee, J. E.; Stermer, R. L.

    1974-01-01

    Single metal alloys have been explored as the cation source in the chemical vapor deposition (CVD) of iron garnets. Growth of good quality single crystal garnet films containing as many as five different cations has been achieved over a wide range of deposition conditions. The relationship of film composition to alloy compositions and deposition conditions has been determined for several materials. By proper choice of the alloy composition and the deposition conditions, uncrazed deposits were grown on (111) gadolinium gallium garnet (GGG) substrates. Data on physical, magnetic and optical properties of representative films is presented and discussed.

  11. Kinetics of low pressure CVD growth of SiO2 on InP and Si

    NASA Technical Reports Server (NTRS)

    Iyer, R.; Lile, D. L.

    1988-01-01

    The kinetics of low pressure CVD growth of SiO2 from SiH4 and O2 has been investigated for the case of an indirect (remote) plasma process. Homogeneous (gas phase) and heterogeneous operating ranges have been experimentally identified. The process was shown to be consistent within the heterogeneous surface-reaction dominated range of operation. A kinetic rate equation is given for growth at 14 W RF power input and 400 mtorr total pressure on both InP and Si substrates. The process exhibits an activation energy of 8.4 + or - 0.6 kcal/mol.

  12. Photoluminescence nonuniformity from self-seeding nuclei in CVD-grown monolayer MoSe2.

    PubMed

    Tian, Xiangling; Wei, Rongfei; Liu, Shanshan; Zhang, Yeming; Qiu, Jianrong

    2018-01-03

    We present optical spectroscopy (photoluminescence and Raman spectrum) studies of monolayer transition metal dichalcogenide MoSe 2 , with spatial location, temperature and excitation power dependence. The investigated spectra show location-dependent behavior with an increase in photoluminescence and Raman intensity and a blue-shift in photoluminescence peak position in the inner region. The observed behaviors of a large shift in the photoluminescence peak position at the edge and biexciton emissions in the inner region confirm that the monolayer MoSe 2 crystals grow from nucleation centers during the CVD process. Temperature activated energy and dependence of the peak position are attributed to residual oxygen during the growth. Investigating this information provides a basis for precisely controlling the synthesis of TMDCs and their application in advanced optoelectronics.

  13. Paralinear Oxidation of CVD SiC in Simulated Fuel-Rich Combustion

    NASA Technical Reports Server (NTRS)

    Fox, Dennis S.; Opila, Elizabeth J.; Hann, Raiford E.

    2000-01-01

    The oxidation kinetics of CVD SiC were measured by thermogravimetric analysis (TGA) in a 4H2 (central dot) 12H2O (central dot) 10CO (central dot) 7CO2 (central dot) 67N2 gas mixture flowing at 0.44 cm/s at temperatures between 1300 and 1450 C in fused quartz furnace tubes at I atm total pressure. The SiC was oxidized to form solid SiO2. At less than or = 1350 C, the SiO2 was in turn volatilized. Volatilization kinetics were consistent with the thermodynamic predictions based on SiO formation. These two simultaneous reactions resulted in overall paralinear kinetics. A curve fitting technique was used to determine the linear and parabolic rate constants from the paralinear kinetic data. Volatilization of the protective SiO2 scale resulted in accelerated consumption of SiC. Recession rates under conditions more representative of actual combustors were estimated from the furnace data.

  14. Graphene growth on Ge(100)/Si(100) substrates by CVD method.

    PubMed

    Pasternak, Iwona; Wesolowski, Marek; Jozwik, Iwona; Lukosius, Mindaugas; Lupina, Grzegorz; Dabrowski, Pawel; Baranowski, Jacek M; Strupinski, Wlodek

    2016-02-22

    The successful integration of graphene into microelectronic devices is strongly dependent on the availability of direct deposition processes, which can provide uniform, large area and high quality graphene on nonmetallic substrates. As of today the dominant technology is based on Si and obtaining graphene with Si is treated as the most advantageous solution. However, the formation of carbide during the growth process makes manufacturing graphene on Si wafers extremely challenging. To overcome these difficulties and reach the set goals, we proposed growth of high quality graphene layers by the CVD method on Ge(100)/Si(100) wafers. In addition, a stochastic model was applied in order to describe the graphene growth process on the Ge(100)/Si(100) substrate and to determine the direction of further processes. As a result, high quality graphene was grown, which was proved by Raman spectroscopy results, showing uniform monolayer films with FWHM of the 2D band of 32 cm(-1).

  15. Channeling effect in polycrystalline deuterium-saturated CVD diamond target bombarded by deuterium ion beam

    NASA Astrophysics Data System (ADS)

    Bagulya, A. V.; Dalkarov, O. D.; Negodaev, M. A.; Rusetskii, A. S.; Chubenko, A. P.; Ralchenko, V. G.; Bolshakov, A. P.

    2015-07-01

    At the ion accelerator HELIS at LPI, the neutron yield is investigated in DD reactions within a strongly textured polycrystalline deuterium-saturated CVD diamond under irradiation by a deuterium ion beam with the energy of less than 30 keV. The measurements of the neutron flux in the beam direction are performed using a multichannel detector based on 3He counters, in dependence on the target angle, β, with respect to the beam axis. A significant anisotropy in the neutron yield is observed. At β = 0° the yield is higher by a factor of 3 as compared to that at β = ±45°. The possible reasons for the anisotropy, including ion channeling, are discussed.

  16. Silicon Oil DC200(R)5CST as AN Alternative Coolant for Cvd Diamond Windows

    NASA Astrophysics Data System (ADS)

    Vaccaro, A.; Aiello, G.; Meier, A.; Schere, T.; Schreck, S.; Spaeh, P.; Strauss, D.; Gantenbein, G.

    2011-02-01

    The production of high power mm-wave radiation is a key technology in large fusion devices, since it is required for localized plasma heating and current drive. Transmission windows are necessary to keep the vacuum in the gyrotron system and also act as tritium barriers. With its excellent optical, thermal and mechanical properties, synthetic CVD (Chemical Vapor Deposition) diamond is the state of the art material for the cw transmission of the mm-wave beams produced by high power gyrotrons. The gyrotrons foreseen for the W7-X stellarator are designed for cw operation with 1 MW output power at 140 GHz. The output window unit is designed by TED (Thales Electron Devices, France) using a single edge circumferentially cooled CVD-diamond disc with an aperture of 88 mm. The window unit is cooled by de-ionized water which is considered as chemical aggressive and might cause corrosion in particular at the brazing. The use of a different coolant such as silicon oil could prevent this issue. The cooling circuit has been simulated by steady-state CFD analysis. A total power generation of 1 kW (RF transmission losses) with pure Gaussian distribution has been assumed for the diamond disc. The performance of both water and the industrial silicon oil DC200(R) have been investigated and compared with a focus on the temperature distribution on the disc, the pressure drop across the cooling path and the heat flux distribution. Although the silicon oil has a higher viscosity (~x5), lower heat capacity (~x1/2) and lower thermal conductivity (~x1/3), it has proven to be a good candidate as alternative to water.

  17. CVD-grown horizontally aligned single-walled carbon nanotubes: synthesis routes and growth mechanisms.

    PubMed

    Ibrahim, Imad; Bachmatiuk, Alicja; Warner, Jamie H; Büchner, Bernd; Cuniberti, Gianaurelio; Rümmeli, Mark H

    2012-07-09

    Single-walled carbon nanotubes (SWCNTs) have attractive electrical and physical properties, which make them very promising for use in various applications. For some applications however, in particular those involving electronics, SWCNTs need to be synthesized with a high degree of control with respect to yield, length, alignment, diameter, and chirality. With this in mind, a great deal of effort is being directed to the precision control of vertically and horizontally aligned nanotubes. In this review the focus is on the latter, horizontally aligned tubes grown by chemical vapor deposition (CVD). The reader is provided with an in-depth review of the established vapor deposition orientation techniques. Detailed discussions on the characterization routes, growth parameters, and growth mechanisms are also provided. Copyright © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  18. Preliminary assessment of the safety and immunogenicity of live oral cholera vaccine strain CVD 103-HgR in healthy Thai adults.

    PubMed Central

    Migasena, S; Pitisuttitham, P; Prayurahong, B; Suntharasamai, P; Supanaranond, W; Desakorn, V; Vongsthongsri, U; Tall, B; Ketley, J; Losonsky, G

    1989-01-01

    A single dose (5 x 10(8) organisms) of attenuated A- B+ Vibrio cholerae classical Inaba recombinant vaccine strain CVD 103-HgR or placebo was administered to 24 healthy young Thai adults in a randomized, placebo-controlled, double-blind trial of safety and immunogenicity. None of the volunteers experienced untoward reactions. The vaccine strain was recovered from 2 of 12 vaccines. The vibriocidal antibody response (the best immunological correlate of protection) was good: 11 of 12 vaccinees (92%) manifested significant serotype-homologous Inaba antibody rises with a peak reciprocal geometric mean titer (RGMT) postvaccination of 3,417; 9 of 12 exhibited significant serotype-heterologous Ogawa antibody rises (prevaccination RGMT, 180; peak RGMT, 2,874). Nine of 12 vaccinees had significant rises in serum antitoxin. None of the controls exhibited rises in vibriocidal or antitoxic antibody. This preliminary study further confirms the safety and immunogenicity of CVD 103-HgR live oral cholera vaccine and paves the way for larger community studies of this candidate cholera vaccine. PMID:2807523

  19. X-ray diffraction characterization of epitaxial CVD diamond films with natural and isotopically modified compositions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Prokhorov, I. A., E-mail: igor.prokhorov@mail.ru; Voloshin, A. E.; Ralchenko, V. G.

    2016-11-15

    Comparative investigations of homoepitaxial diamond films with natural and modified isotopic compositions, grown by chemical vapor deposition (CVD) on type-Ib diamond substrates, are carried out using double-crystal X-ray diffractometry and topography. The lattice mismatch between the substrate and film is precisely measured. A decrease in the lattice constant on the order of (Δa/a){sub relax} ∼ (1.1–1.2) × 10{sup –4} is recorded in isotopically modified {sup 13}C (99.96%) films. The critical thicknesses of pseudomorphic diamond films is calculated. A significant increase in the dislocation density due to the elastic stress relaxation is revealed by X-ray topography.

  20. Prevalence of normal weight central obesity among Thai healthcare providers and their association with CVD risk: a cross-sectional study.

    PubMed

    Thaikruea, Lakkana; Thammasarot, Jiraporn

    2016-11-16

    This study aims to determine the prevalence of health personnel with normal weight central obesity and to investigate whether this group had higher cardiovascular disease (CVD) risk factors than those of the people with normal weight and without central obesity. A waist-to-height ratio was calculated as waist circumference (at umbilical level) in cm divided by height in cm. The central obesity cut-off level was 0.5. The body mass index was calculated as weight in kg divided by height in meters squared. The obesity cut-off level was 25 kg/m 2 . The prevalence of health personnel with normal weight central obesity was 15.4% (499 out of 3235). When compare this group to 1787 health personnel who had normal weight and without central obesity, they were 2.03 times (95% CI of adjusted OR; 1.62 to 2.54) more likely to have at least one CVD factor. The waist-to-height ratio cut-off value of 0.5 can be used as a self-assessment tool for central obesity without the need for a standard measuring tape. It is feasible to be implemented in screening or self-monitoring for the general population.

  1. High efficiency epitaxial GaAs/GaAs and GaAs/Ge solar cell technology using OM/CVD

    NASA Technical Reports Server (NTRS)

    Wang, K. L.; Yeh, Y. C. M.; Stirn, R. J.; Swerdling, S.

    1980-01-01

    A technology for fabricating high efficiency, thin film GaAs solar cells on substrates appropriate for space and/or terrestrial applications was developed. The approach adopted utilizes organometallic chemical vapor deposition (OM-CVD) to form a GaAs layer epitaxially on a suitably prepared Ge epi-interlayer deposited on a substrate, especially a light weight silicon substrate which can lead to a 300 watt per kilogram array technology for space. The proposed cell structure is described. The GaAs epilayer growth on single crystal GaAs and Ge wafer substrates were investigated.

  2. CVD-grown monolayer MoS2 in bioabsorbable electronics and biosensors.

    PubMed

    Chen, Xiang; Park, Yong Ju; Kang, Minpyo; Kang, Seung-Kyun; Koo, Jahyun; Shinde, Sachin M; Shin, Jiho; Jeon, Seunghyun; Park, Gayoung; Yan, Ying; MacEwan, Matthew R; Ray, Wilson Z; Lee, Kyung-Mi; Rogers, John A; Ahn, Jong-Hyun

    2018-04-27

    Transient electronics represents an emerging technology whose defining feature is an ability to dissolve, disintegrate or otherwise physically disappear in a controlled manner. Envisioned applications include resorbable/degradable biomedical implants, hardware-secure memory devices, and zero-impact environmental sensors. 2D materials may have essential roles in these systems due to their unique mechanical, thermal, electrical, and optical properties. Here, we study the bioabsorption of CVD-grown monolayer MoS 2 , including long-term cytotoxicity and immunological biocompatibility evaluations in biofluids and tissues of live animal models. The results show that MoS 2 undergoes hydrolysis slowly in aqueous solutions without adverse biological effects. We also present a class of MoS 2 -based bioabsorbable and multi-functional sensor for intracranial monitoring of pressure, temperature, strain, and motion in animal models. Such technology offers specific, clinically relevant roles in diagnostic/therapeutic functions during recovery from traumatic brain injury. Our findings support the broader use of 2D materials in transient electronics and qualitatively expand the design options in other areas.

  3. Microstructural and strength stability of a developmental CVD SiC fiber

    NASA Technical Reports Server (NTRS)

    Bhatt, Ramakrishna T.; Garg, Anita; Hull, David R.

    1995-01-01

    The effects of thermal exposure on the room temperature tensile strength and microstructure of a developmental 50 micron CVD SiC fiber have been studied. The fibers were heat treated between 600 and 2000 C in 0.1 MPa argon and air environments for up to 100 hr. In the as-fabricated condition, the fibers showed approximately 6 GPa tensile strength. After argon treatment, the fibers showed strength degradation after 1 hr exposure beyond 1000 C, but those exposed between 1600 and 2000 C retained approximately 2 GPa strength. TEM results showed microstructural changes both in the surface coating and SiC sheath. Flaws created by the rearrangement of carbon in the surface coating and growth of equiaxed SiC grain zone in the SiC sheath are the suggested mechanisms of strength degradation. After air treatment, fibers showed strength degradation after only 2 min exposure at 600 C. Strength retention after 2 min at 1500 C was approximately 2 GPa. Oxidation of the surface coating is the primary reason for strength degradation.

  4. Femoral-gluteal subcutaneous and intermuscular adipose tissues have independent and opposing relationships with CVD risk

    PubMed Central

    Yim, Jung-Eun; Heshka, Stanley; Albu, Jeanine B.; Heymsfield, Steven; Gallagher, Dympna

    2009-01-01

    —Femoral-gluteal adipose tissue (AT) may be cardioprotective through fatty acids uptake. Femoral-gluteal AT has previously been defined as leg fat measured by dual energy x-ray absorptiometry (DXA); however, subcutaneous adipose tissue (SAT) and intermuscular adipose tissue (IMAT) are inseparable using DXA. This study investigated the independent relationships between femoral-gluteal SAT, femoral-gluteal IMAT, and cardiovascular disease (CVD) risk factors [fasting serum measures of glucose, total cholesterol (TC), high density lipoprotein cholesterol (HDLC), triglycerides (TG) and insulin] and whether race differences exist in femoral-gluteal AT distribution. Adult Caucasians (56 men and 104 women), African-Americans (37 men and 76 women), and Asians (11 men and 35 women) had total AT (TAT) including femoral-gluteal AT (upper leg SAT and IMAT) and visceral AT (VAT) by magnetic resonance imaging (MRI). General linear models identified the independent effects of femoral-gluteal SAT and femoral-gluteal IMAT on each risk factor after covarying for TAT, VAT, age, race, sex, and two-way interactions. Femoral-gluteal IMAT and glucose (P < 0.05) were positively associated independent of VAT. There were also significant inverse associations between femoral-gluteal SAT and insulin (P < 0.01) and TG (P < 0.05), although the addition of VAT rendered these effects nonsignificant, possibly due to collinearity. Asian women had less femoral-gluteal SAT and greater VAT than Caucasians and African-Americans (P < 0.05) and Asian and African-American men had greater femoral-gluteal IMAT than Caucasians, adjusted for age and TAT (P < 0.05 for both). Femoral-gluteal SAT and femoral-gluteal IMAT distribution varies by sex and race, and these two components have independent and opposing relationships with CVD risk factors. PMID:18079271

  5. Cardiovascular disease (CVD) risk factors in Kraków and in the whole Poland adult population. Results from the WOBASZ study and Polish arm of the HAPIEE project.

    PubMed

    Doryńska, Agnieszka; Polak, Maciej; Kozela, Magdalena; Szafraniec, Krystyna; Piotrowski, Walerian; Bielecki, Wojciech; Drygas, Wojciech; Kozakiewicz, Krystyna; Piwoński, Jerzy; Tykarski, Andrzej; Zdrojewski, Tomasz; Pająk, Andrzej

    2015-01-01

    In Kraków, the second largest town in Poland, cardiovascular disease (CVD) mortality rate is lower than in most top largest towns in Poland and lower than the rate for total Polish population. The aim of the present analysis was to compare socioeconomic status (SES), prevalence of CVD risk factors and SCORE assessment of risk in Krakow with residents of other big towns in Poland and with general Polish population. We used data from the two large, population studies which used comparable methods for risk factors assessment: 1) Polish part of the HAPIEE Project in which 10 615 residents of Krakow at age between 45-69 years were examined, and (2) The WOBASZ Study which contributed with a sub-sample 6 888 of residents of Poland at corresponding age group. WOBASZ sample included 992 residents of big towns other than Krakow. Age-standardized proportions of persons with CVD risk factors were compared between Krakow and the other big towns in Poland and between Krakow and the whole Poland using χ2 test. The striking observation was that in Krakow proportions of participants with university education were substantially higher than average for the other big towns and the whole Poland. Also, the proportion of occupationally active men and women was the highest in Krakow. In both sexes, prevalence of smoking, hypercholesterolemia and hypertension in Krakow was similar to the other big towns but the prevalence of hypercholesterolemia and hypertension (in men only) was lower than average for Poland. The distribution by SCORE risk categories were similar in all three samples studied. In general, the distribution by BMI categories was less favourable but the prevalence of central obesity was lower among residents of Kraków than among residents of the other big towns and citizens of the whole Poland. Prevalence of diabetes was higher in Krakow than in the other samples studied. The differences between population of Krakow and population of other parts of Poland in the exposure

  6. Chronic ingestion of flavan-3-ols and isoflavones improves insulin sensitivity and lipoprotein status and attenuates estimated 10-year CVD risk in medicated postmenopausal women with type 2 diabetes: a 1-year, double-blind, randomized, controlled trial.

    PubMed

    Curtis, Peter J; Sampson, Mike; Potter, John; Dhatariya, Ketan; Kroon, Paul A; Cassidy, Aedín

    2012-02-01

    To assess the effect of dietary flavonoids on cardiovascular disease (CVD) risk in postmenopausal women with type 2 diabetes on established statin and hypoglycemic therapy. Despite being medicated, patients with type 2 diabetes have elevated CVD risk, particularly postmenopausal women. Although dietary flavonoids have been shown to reduce CVD risk factors in healthy participants, no long-term trials have examined the additional benefits of flavonoids to CVD risk in medicated postmenopausal women with type 2 diabetes. We conducted a parallel-design, placebo-controlled trial with type 2 diabetic patients randomized to consume 27 g/day (split dose) flavonoid-enriched chocolate (containing 850 mg flavan-3-ols [90 mg epicatechin] and 100 mg isoflavones [aglycone equivalents)]/day) or matched placebo for 1 year. Ninety-three patients completed the trial, and adherence was high (flavonoid 91.3%; placebo 91.6%). Compared with the placebo group, the combined flavonoid intervention resulted in a significant reduction in estimated peripheral insulin resistance (homeostasis model assessment of insulin resistance [HOMA-IR] -0.3 ± 0.2; P = 0.004) and improvement in insulin sensitivity (quantitative insulin sensitivity index [QUICKI] 0.003 ± 0.00; P = 0.04) as a result of a significant decrease in insulin levels (-0.8 ± 0.5 mU/L; P = 0.02). Significant reductions in total cholesterol:HDL-cholesterol (HDL-C) ratio (-0.2 ± 0.1; P = 0.01) and LDL-cholesterol (LDL-C) (-0.1 ± 0.1 mmol/L; P = 0.04) were also observed. Estimated 10-year total coronary heart disease risk (derived from UK Prospective Diabetes Study algorithm) was attenuated after flavonoid intervention (flavonoid +0.1 ± 0.3 vs. placebo 1.1 ± 0.3; P = 0.02). No effect on blood pressure, HbA(1c), or glucose was observed. One-year intervention with flavan-3-ols and isoflavones improved biomarkers of CVD risk, highlighting the additional benefit of flavonoids to standard drug therapy in managing CVD risk in

  7. An assessment study of CVD related risk factors in a tribal population of India.

    PubMed

    Kandpal, Vani; Sachdeva, M P; Saraswathy, K N

    2016-05-25

    Non communicable diseases (NCDs) have become a major concern for global health. Cardiovascular diseases (CVDs) contribute 48 % towards the deaths due to NCDs in India. Though studies have been conducted in urban and rural areas, data related to tribal communities is limited. The present study aims to examine various CVD related risk factors including hypertension, elevated fasting blood glucose, obesity and metabolic syndrome among a tribal population. The present study was an observational, cross- sectional study conducted on Rang Bhotias, a tribal population of India. The participants were adults of age between 20 and 60 years. Prior to blood sample collection, interview schedule was administered which included relevant information like age, lifestyle, socio-economic status, education and occupation In addition to this, various anthropometric and physiological measurements were taken. Logistic regression was used to examine the association of the various health disorders related to CVDs with age, gender and behavioural factors (smoking, alcohol consumption and physical activity). A total of 288 participants were surveyed for the study including 104 males and 184 females. High BMI (56.6 %), hypertension (43.4 %), metabolic syndrome (39.2 %) and abdominal obesity (33.7 %) were the most prevalent CVD risk factors observed in the population. The multivariate logistic regression analysis, conducted to examine the contribution of risk factors including behavioural risk factors on the studied abnormalities, revealed age to be a significant risk factor for all the abnormalities except elevated fasting blood glucose. Gender and physical inactivity contributed significantly towards development of hypertension. Physical inactivity was also found to be associated with high BMI levels. In the present study, hypertension, high BMI levels, MS and abdominal obesity have been found to be high among the studied population. The status of the population with respect to these

  8. In cross-sectional observations, dietary quality is not associated with CVD risk in women; in men the positive association is accounted for by BMI

    USDA-ARS?s Scientific Manuscript database

    The role that BMI plays in the association between dietary quality and CVD risk is not known. We aimed to better understand this relationship using statistical methods which correct for sex-specific underreporting of dietary intake. Overall, dietary quality was assessed using the Healthy Eating Inde...

  9. Use of Kelvin probe force microscopy for identification of CVD grown graphene flakes on copper foil

    NASA Astrophysics Data System (ADS)

    Kumar, Rakesh; Mehta, B. R.; Kanjilal, D.

    2017-05-01

    Graphene flakes have been grown by chemical vapour deposition (CVD) method on Cu foils. The obtained graphene flakes have been characterized by optical microscopy, field emission scanning electron microscopy, Kelvin probe force microscopy (KPFM) and Raman spectroscopy. The graphene flakes grown on Cu foil comprise mainly single layer graphene and confirm that the nucleation for graphene growth starts very quickly. Moreover, KPFM has been found to be a valuable technique to differentiate between covered and uncovered portion of Cu foil by graphene flakes deposited for shorter duration. The results show that KPFM can be a very useful technique in understanding the mechanism of graphene growth.

  10. I-123 amphetamine vs Xe-133 SPECT: A comparative study in patients with unilateral Cerebrovascular Disease (CVD)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Buell, U.; Krappel, W.; Schmiedek, P.

    1985-05-01

    SPECT may be used to measure regional cerebral blood flow (rCBF) by X) Xe-133 gas and a rotating four detector array system or by I) I-123 amphetamine (IMP) and a rotating gamma camera. Results of X) and I) were compared to find out an optimum time frame wherein cerebral IMP distribution reflects rCBF, using Xe-133 as reference. In 20 patients (pts) with strictly unilateral CFD, X) and I) were performed within 48 hrs. X) was used to establish interhemispherical ratios (R) of rCBF (diseased-to-normal hemisphere) from both, hemispherical (half) slices (S, at 6-8 and 10-12 cm above OML, 2 SRmore » per pt) and standardized areas (A, 6 AR per S). I) was done with a dual head gamma camera at (2) 13-27, (2) 33-47 min and (3) 5.5. hrs after injection of 180 MBq IMP-123 (p,5n). After reconstruction, identical S of X) and I) were evaluated by a ROI computer program. For comparison, values of SR and AR were subtracted from l.000 and pronounced CVD was selected by thresholds for XE-R (>.11 and >.14). In pronounced CVD, IMP(2)SR was significantly different from Xe SR. AR showed a low correlation, too. At 5.5 hrs, IMP 3 did represent rCBF at least. However, excellent congruence was found at IMP 1 (13-27 min pi.) The authors conclude that in CVED cerebral IMP uptake and distribution represent rCBF only during the first 30 min after injection.« less

  11. LARGE—A Plasma Torch for Surface Chemistry Applications and CVD Processes—A Status Report

    NASA Astrophysics Data System (ADS)

    Zimmermann, Stephan; Theophile, Eckart; Landes, Klaus; Schein, Jochen

    2008-12-01

    The LARGE ( LONG ARG GENERATOR) is a new generation DC-plasma torch featuring an extended arc which is operated with a perpendicular gas flow to create a wide (up to 45 cm) plasma jet well suited for large area plasma processing. Using plasma diagnostic systems like high speed imaging, enthalpy probe, emission spectroscopy, and tomography, the LARGE produced plasma jet characteristics have been measured and sources of instability have been identified. With a simple model/simulation of the system LARGE III-150 and numerous experimental results, a new nozzle configuration and geometry (LARGE IV-150) has been designed, which produces a more homogenous plasma jet. These improvements enable the standard applications of the LARGE plasma torch (CVD coating process and surface activation process) to operate with higher efficiency.

  12. CVD-MPFA full pressure support, coupled unstructured discrete fracture-matrix Darcy-flux approximations

    NASA Astrophysics Data System (ADS)

    Ahmed, Raheel; Edwards, Michael G.; Lamine, Sadok; Huisman, Bastiaan A. H.; Pal, Mayur

    2017-11-01

    Two novel control-volume methods are presented for flow in fractured media, and involve coupling the control-volume distributed multi-point flux approximation (CVD-MPFA) constructed with full pressure support (FPS), to two types of discrete fracture-matrix approximation for simulation on unstructured grids; (i) involving hybrid grids and (ii) a lower dimensional fracture model. Flow is governed by Darcy's law together with mass conservation both in the matrix and the fractures, where large discontinuities in permeability tensors can occur. Finite-volume FPS schemes are more robust than the earlier CVD-MPFA triangular pressure support (TPS) schemes for problems involving highly anisotropic homogeneous and heterogeneous full-tensor permeability fields. We use a cell-centred hybrid-grid method, where fractures are modelled by lower-dimensional interfaces between matrix cells in the physical mesh but expanded to equi-dimensional cells in the computational domain. We present a simple procedure to form a consistent hybrid-grid locally for a dual-cell. We also propose a novel hybrid-grid for intersecting fractures, for the FPS method, which reduces the condition number of the global linear system and leads to larger time steps for tracer transport. The transport equation for tracer flow is coupled with the pressure equation and provides flow parameter assessment of the fracture models. Transport results obtained via TPS and FPS hybrid-grid formulations are compared with the corresponding results of fine-scale explicit equi-dimensional formulations. The results show that the hybrid-grid FPS method applies to general full-tensor fields and provides improved robust approximations compared to the hybrid-grid TPS method for fractured domains, for both weakly anisotropic permeability fields and very strong anisotropic full-tensor permeability fields where the TPS scheme exhibits spurious oscillations. The hybrid-grid FPS formulation is extended to compressible flow and the

  13. Transport mechanisms through PE-CVD coatings: influence of temperature, coating properties and defects on permeation of water vapour

    NASA Astrophysics Data System (ADS)

    Kirchheim, Dennis; Jaritz, Montgomery; Mitschker, Felix; Gebhard, Maximilian; Brochhagen, Markus; Hopmann, Christian; Böke, Marc; Devi, Anjana; Awakowicz, Peter; Dahlmann, Rainer

    2017-03-01

    Gas transport mechanisms through plastics are usually described by the temperature-dependent Arrhenius-model and compositions of several plastic layers are represented by the CLT. When it comes to thin films such as plasma-enhanced chemical vapour deposition (PE-CVD) or plasma-enhanced atomic layer deposition (PE-ALD) coatings on substrates of polymeric material, a universal model is lacking. While existing models describe diffusion through defects, these models presume that permeation does not occur by other means of transport mechanisms. This paper correlates the existing transport models with data from water vapour transmission experiments.

  14. Growth studies of CVD-MBE by in-situ diagnostics

    NASA Astrophysics Data System (ADS)

    Maracas, George N.; Steimle, Timothy C.

    1992-10-01

    This is the final technical report for the three year DARPA-URI program 'Growth Studies of CVD-MBE by in-situ Diagnostics'. The goals of the program were to develop non-invasive, real time epitaxial growth monitoring techniques and combine them to gain an understanding of processes that occur during MBE growth from gas sources. We have adapted these techniques to a commercially designed gas source MBE system (Vacuum Generators Inc.) to facilitate technology transfer out of the laboratory into industrial environments. The in-situ measurement techniques of spectroscopic ellipsometry (SE) and laser induced fluorescence (LIF) have been successfully implemented to monitor the optical and chemical properties of the growing epitaxial film and the gas phase reactants. The ellipsometer was jointly developed with the J. Woolam Co. and has become a commercial product. The temperature dependence of group 3 and 5 desorption from GaAs and InP has been measured as well as the incident effusion cell fluxes. The temporal evolution of the growth has also been measured both by SE and LIF to show the smoothing of heterojunction surfaces during growth interruption. Complicated microcavity optical device structures have been monitored by ellipsometry in real time to improve device quality. This data has been coupled with the structural information obtained from reflection high energy electron diffraction (RHEED) to understand the growth processes in binary and ternary bulk 3-5 semiconductors and heterojunctions.

  15. Single crystal CVD diamond membranes as Position Sensitive X-ray Detector

    NASA Astrophysics Data System (ADS)

    Desjardins, K.; Menneglier, C.; Pomorski, M.

    2017-12-01

    Transparent X-ray Beam Position Monitor (XBPM) has been specifically developed for low energy X-ray beamlines (1.4 keV < E < 5 keV) allowing to transmit more than 80% of 2 keV energy beam. The detector is based on a free-standing single crystal CVD diamond membrane of 4 μm thickness with position-sensitive DLC (Diamond-Like Carbon) resistive electrodes in duo-lateral configuration. The measured X-ray beam induced current (XBIC) due to the interaction of X-rays with diamond membrane allows precise monitoring of the absolute beam flux and the beam position (by the reconstruction of its center-of-gravity) at beam transmissions reaching 95%. This detector has been installed at SOLEIL synchrotron on the SIRIUS beamline monochromator output and it has shown charge collection efficiency (CCE) reaching 100% with no lag-effects and excellent beam intensity sensitivity monitoring. X-ray beam mapping of the detector showed an XBIC response inhomogeneity of less than 10% across the membrane, corresponding mainly to the measured variation of the diamond plate thickness. The measured beam position resolution is at sub-micron level depending on the beam flux and the readout electronics bandwidth.

  16. Is physical activity maintenance from adolescence to young adulthood associated with reduced CVD risk factors, improved mental health and satisfaction with life: the HUNT Study, Norway.

    PubMed

    Rangul, Vegar; Bauman, Adrian; Holmen, Turid Lingaas; Midthjell, Kristian

    2012-12-14

    Little is known about the effect maintaining physical activity throughout adolescence has on cardiovascular risk factors and health status in early adulthood. This ten-year prospective longitudinal study investigated whether differences in physical activity patterns from adolescence to young-adulthood showed different associations with subsequent cardio-metabolic risk factors and mental health in young-adulthood. Based on the second and third Norwegian Nord-Trøndelag Health Surveys (HUNT2 and 3), we included 1869 individuals (838 males) participating in Young-HUNT (1995-97), aged 13-19 years and followed-up at HUNT3 (2006-08), aged 23-31. Self-reported physical activity (PA), mental health and perceived health were recorded, along with measurements of body mass index (BMI), waist circumference (WC), total cholesterol (TC), HDL cholesterol, glucose, triglycerides, resting heart rate (HR) and blood pressure. We used separate linear regressions models to investigate associations between physical activity and each CVD risk factor, and logistic regression analysis to examine PA patterns and subsequent mental health. Physically active maintainers were compared to inactive maintainers. Adopters (inactive as adolescents and physically active as young adults) were compared to inactive maintainers and to those who discontinued activity (relapsers). Active maintainers had significantly lower HR, compared to all other PA patterns. Active maintaining men had significantly lower WC than relapsers and inactive maintainers. When adjusted for age and gender, WC, BMI, HR, diastolic blood pressure and HDL-C showed significant differences comparing active maintaining to other PA patterns. Comparing inactive maintainers against adopters, only HR was significantly lower. Male adopters did not differ significantly in CVD risk compared to inactive maintainers and relapsers. Among females adopting was associated with lower HR and TC compared to inactive maintainers. Active maintainers

  17. Effect of microstructure on the corrosion of CVD-SiC exposed to supercritical water

    NASA Astrophysics Data System (ADS)

    Tan, L.; Allen, T. R.; Barringer, E.

    2009-10-01

    Silicon carbide (SiC) is an important engineering material being studied for potential use in multiple nuclear energy systems including high-temperature gas-cooled reactors and water-cooled reactors. The corrosion behavior of SiC exposed to supercritical water (SCW) is critical for examining its applications in nuclear reactors. Although the hydrothermal corrosion of SiC has been the subject of many investigations, the study on the microstructural effects on the corrosion is limited. This paper presents the effect of residual strain, grain size, grain boundary types, and surface orientations on the corrosion of chemical vapor deposited (CVD) β-SiC exposed to SCW at 500 °C and 25 MPa. Weight loss occurred on all the samples due to localized corrosion. Residual strains associated with small grains showed the most significant effect on the corrosion compared to the other factors.

  18. The integration of epigenetics and genetics in nutrition research for CVD risk factors.

    PubMed

    Ma, Yiyi; Ordovas, Jose M

    2017-08-01

    There is increasing evidence documenting gene-by-environment (G × E) interactions for CVD related traits. However, the underlying mechanisms are still unclear. DNA methylation may represent one of such potential mechanisms. The objective of this review paper is to summarise the current evidence supporting the interplay among DNA methylation, genetic variants, and environmental factors, specifically (1) the association between SNP and DNA methylation; (2) the role that DNA methylation plays in G × E interactions. The current evidence supports the notion that genotype-dependent methylation may account, in part, for the mechanisms underlying observed G × E interactions in loci such as APOE, IL6 and ATP-binding cassette A1. However, these findings should be validated using intervention studies with high level of scientific evidence. The ultimate goal is to apply the knowledge and the technology generated by this research towards genetically based strategies for the development of personalised nutrition and medicine.

  19. Raman spectra boron doped amorphous carbon thin film deposited by bias assisted-CVD

    NASA Astrophysics Data System (ADS)

    Ishak, A.; Fadzilah, A. N.; Dayana, K.; Saurdi, I.; Malek, M. F.; Nurbaya, Z.; Shafura, A. K.; Rusop, M.

    2018-05-01

    Boron doped amorphous carbon thin film carbon was deposited at 200°C-350°C by bias assisted-CVD using palm oil as a precursor material. The structural boron doped amorphous carbon films were discussed by Raman analysis through the evolution of D and G bands. The spectral evolution observed showed the increase of upward shift of D and G peaks as substrate deposition temperatures increased. These structural changes were further correlated with optical gap and the results obtained are discussed and compared. The estimated optical band gap is found to be 1.9 to 2.05 eV and conductivity is to be in the range of 10-5 Scm-1 to 10-4 Scm-1. The decrease of optical band gap is associated to conductivity increased which change the characteristic parameters of Raman spectra including the position of G peak, full width at half maximum of G peak, and ID/IG.

  20. Orientation effect in d(d,n)3He reaction initiated by 20 keV deuterons at channeling in textured CVD-Diamond target

    NASA Astrophysics Data System (ADS)

    Bagulya, A. V.; Dalkarov, O. D.; Negodaev, M. A.; Pivovarov, Yu. L.; Rusetskii, A. S.; Tukhfatullin, T. A.

    2017-07-01

    Orientation effect of increasing the enhancement factor of DD-reaction in CVD-Diamond was investigated by simulation. It is obtained that the flux peaking effect up to 2.2 times increases the relative enhancement factor for a parallel beam and up to 1.2 times for the deuteron beam with angular divergence equals 3 critical channeling angles. Qualitative agreement with the experiment was obtained.

  1. Evidence-based new service package vs. routine service package for smoking cessation to prevent high risk patients from cardiovascular diseases (CVD): study protocol for randomized controlled trial.

    PubMed

    Aung, Myo Nyein; Yuasa, Motoyuki; Lorga, Thaworn; Moolphate, Saiyud; Fukuda, Hiroshi; Kitajima, Tsutomu; Yokokawa, Hirohide; Minematsu, Kazuo; Tanimura, Susumu; Hiratsuka, Yoshimune; Ono, Koichi; Naunboonruang, Prissana; Thinuan, Payom; Kawai, Sachio; Suya, Yaoyanee; Chumvicharana, Somboon; Marui, Eiji

    2013-12-05

    Smoking cessation is a high-priority intervention to prevent CVD events and deaths in developing countries. While several interventions to stop smoking have been proved successful, the question of how to increase their effectiveness and practicality in developing countries remains. In this study, a newly devised evidence-based smoking cessation service package will be compared with the existing service in a randomized controlled trial within the community setting of Thailand. This randomized control trial will recruit 440 current smokers at CVD risk because of being diabetic and/or hypertensive. Informed, consented participants will be randomly allocated into the new service-package arm and the routine service arm. The study will take place in the non-communicable disease clinics of the Maetha District Hospital, Lampang, northern Thailand. The new smoking-cessation service-package comprises (1) regular patient motivation and coaching from the same primary care nurse over a 3-month period; (2) monthly application of piCO + smokerlyzer to sustain motivation of smoker's quitting attempt and provide positive feedback over a 3-month period; (3) assistance by an assigned family member; (4) nicotine replacement chewing gum to relieve withdrawal symptoms. This new service will be compared with the traditional routine service comprising the 5A approach in a 1-year follow-up. Participants who consent to participate in the study but refuse to attempt quitting smoking will be allocated to the non-randomized arm, where they will be just followed up and monitored. Primary outcome of the study is smoking cessation rate at 1-year follow-up proven by breath analysis measuring carbomonoxide in parts per million in expired air. Secondary outcomes are smoking cessation rate at the 6-month follow-up, blood pressure and heart rate, CVD risk according to the Framingham general cardiovascular risk score, CVD events and deaths at the 12-month follow-up, and the cost-effectiveness of the

  2. Ternary Precursors for Depositing I-III-VI2 Thin Films for Solar Cells via Spray CVD

    NASA Technical Reports Server (NTRS)

    Banger, K. K.; Hollingsworth, J. A.; Jin, M. H.-C.; Harris, J. D.; Duraj, S. A.; Smith, M.; Scheiman, D.; Bohannan, E. W.; Switzer, J. A.; Buhro, W. E.

    2002-01-01

    The development of thin-film solar cells on flexible, lightweight, space-qualified substrates provides an attractive cost solution to fabricating solar arrays with high specific power (W/kg). Thin-film fabrication studies demonstrate that ternary single source precursors (SSP's) can be used in either a hot or cold-wall spray chemical vapour deposition (CVD) reactor, for depositing CuInS2, CuGaS2, and CuGaInS2 at reduced temperatures (400 to 450 C), which display good electrical and optical properties suitable for photovoltaic (PV) devices. X-ray diffraction studies, energy dispersive spectroscopy (EDS), and scanning electron microscopy (SEM) confirmed the formation of the single phase CIS, CGS, CIGS thin-films on various substrates at reduced temperatures.

  3. Numerical Analysis of an Impinging Jet Reactor for the CVD and Gas-Phase Nucleation of Titania

    NASA Technical Reports Server (NTRS)

    Gokoglu, Suleyman A.; Stewart, Gregory D.; Collins, Joshua; Rosner, Daniel E.

    1994-01-01

    We model a cold-wall atmospheric pressure impinging jet reactor to study the CVD and gas-phase nucleation of TiO2 from a titanium tetra-iso-propoxide (TTIP)/oxygen dilute source gas mixture in nitrogen. The mathematical model uses the computational code FIDAP and complements our recent asymptotic theory for high activation energy gas-phase reactions in thin chemically reacting sublayers. The numerical predictions highlight deviations from ideality in various regions inside the experimental reactor. Model predictions of deposition rates and the onset of gas-phase nucleation compare favorably with experiments. Although variable property effects on deposition rates are not significant (approximately 11 percent at 1000 K), the reduction rates due to Soret transport is substantial (approximately 75 percent at 1000 K).

  4. The Role of Built Environments in Physical Activity, Obesity, and CVD

    PubMed Central

    Sallis, James F.; Floyd, Myron F.; Rodríguez, Daniel A.; Saelens, Brian E.

    2012-01-01

    In industrialized nations like the United States and Sweden, the vast majority of adults do not meet the physical activity guidelines of 150 minutes per week.1 Inactive lifestyles put most adults at risk of cardiovascular diseases (CVD), diabetes, obesity, some cancers, osteoporosis, and psychological disorders.2 Physical activity can be effective at all phases of chronic disease management, from primordial prevention (prevention of risk factors) through treatment and rehabilitation.2 There is particular interest in the potential for physical activity to prevent chronic diseases, thereby improving quality of life and reducing health care costs.3 In the past decade, limitations of prevention approaches that target mainly individuals with educational and motivational programs have been recognized, triggering a trend to consider influences on behavior that are outside the person, such as the built environment.4,5 The purposes of the present paper are to describe multilevel ecological models of behavior as they apply to physical activity, describe key concepts, summarize evidence on the relation of built environment attributes to physical activity and obesity, and provide recommendations for built environment changes that could increase physical activity. The intent of this non-systematic review is to present conclusions from previous reviews then illustrate results by highlighting selected studies. PMID:22311885

  5. Luminescence and conductivity studies on CVD diamond exposed to UV light

    NASA Astrophysics Data System (ADS)

    Bizzarri, A.; Bogani, F.; Bruzzi, M.; Sciortino, S.

    1999-04-01

    The photoluminescence (PL), thermoluminescence (TL) and thermally stimulated currents (TSC) of four high-quality CVD diamond films have been investigated in the range of temperatures between 300 and 700 K. The sample excitation has been carried out by means of an UV xenon lamp and UV laser lines. The features of the signals have been found equal to those obtained from particle excitation. The TL analysis shows the existence of several deep traps with activation energies between 0.6 and 1.0 eV. The contribution to the TL signal from different traps has been singled out by means of successive annealing processes. The TL results are in good agreement with those obtained from TSC measurements. The combined use of the two techniques allows a precise determination of the trap parameters. The spectral content of the TL response has also been compared with the PL signal in order to investigate the recombination process. This analysis shows that, in this temperature range, the TL signal is likely due to recombination from bound states rather than due to radiative free to bound transitions, as generally assumed in TL theory. The TSC signal is likely to arise from impurity band rather than from free carriers conduction.

  6. Wear Mechanism of Chemical Vapor Deposition (CVD) Carbide Insert in Orthogonal Cutting Ti-6Al-4V ELI at High Cutting Speed

    NASA Astrophysics Data System (ADS)

    Gusri, A. I.; Che Hassan, C. H.; Jaharah, A. G.

    2011-01-01

    The performance of Chemical Vapor Deposition (CVD) carbide insert with ISO designation of CCMT 12 04 04 LF, when turning titanium alloys was investigated. There were four layers of coating materials for this insert i.e.TiN-Al2O3-TiCN-TiN. The insert performance was evaluated based on the insert's edge resistant towards the machining parameters used at high cutting speed range of machining Ti-6Al-4V ELI. Detailed study on the wear mechanism at the cutting edge of CVD carbide tools was carried out at cutting speed of 55-95 m/min, feed rate of 0.15-0.35 mm/rev and depth of cut of 0.10-0.20 mm. Wear mechanisms such as abrasive and adhesive were observed on the flank face. Crater wear due to diffusion was also observed on the rake race. The abrasive wear occurred more at nose radius and the fracture on tool were found at the feed rate of 0.35 mm/rev and the depth of cut of 0.20 mm. The adhesion wear takes place after the removal of the coating or coating delaminating. Therefore, adhesion or welding of titanium alloy onto the flank and rake faces demonstrates a strong bond at the workpiece-tool interface.

  7. Is physical activity maintenance from adolescence to young adulthood associated with reduced CVD risk factors, improved mental health and satisfaction with life: the HUNT Study, Norway

    PubMed Central

    2012-01-01

    Background Little is known about the effect maintaining physical activity throughout adolescence has on cardiovascular risk factors and health status in early adulthood. This ten-year prospective longitudinal study investigated whether differences in physical activity patterns from adolescence to young-adulthood showed different associations with subsequent cardio-metabolic risk factors and mental health in young-adulthood. Methods Based on the second and third Norwegian Nord-Trøndelag Health Surveys (HUNT2 and 3), we included 1869 individuals (838 males) participating in Young-HUNT (1995–97), aged 13–19 years and followed-up at HUNT3 (2006–08), aged 23–31. Self-reported physical activity (PA), mental health and perceived health were recorded, along with measurements of body mass index (BMI), waist circumference (WC), total cholesterol (TC), HDL cholesterol, glucose, triglycerides, resting heart rate (HR) and blood pressure. We used separate linear regressions models to investigate associations between physical activity and each CVD risk factor, and logistic regression analysis to examine PA patterns and subsequent mental health. Physically active maintainers were compared to inactive maintainers. Adopters (inactive as adolescents and physically active as young adults) were compared to inactive maintainers and to those who discontinued activity (relapsers). Results Active maintainers had significantly lower HR, compared to all other PA patterns. Active maintaining men had significantly lower WC than relapsers and inactive maintainers. When adjusted for age and gender, WC, BMI, HR, diastolic blood pressure and HDL-C showed significant differences comparing active maintaining to other PA patterns. Comparing inactive maintainers against adopters, only HR was significantly lower. Male adopters did not differ significantly in CVD risk compared to inactive maintainers and relapsers. Among females adopting was associated with lower HR and TC compared to inactive

  8. The role of NH3 and hydrocarbon mixtures in GaN pseudo-halide CVD: a quantum chemical study.

    PubMed

    Gadzhiev, Oleg B; Sennikov, Peter G; Petrov, Alexander I; Kachel, Krzysztof; Golka, Sebastian; Gogova, Daniela; Siche, Dietmar

    2014-11-01

    The prospects of a control for a novel gallium nitride pseudo-halide vapor phase epitaxy (PHVPE) with HCN were thoroughly analyzed for hydrocarbons-NH3-Ga gas phase on the basis of quantum chemical investigation with DFT (B3LYP, B3LYP with D3 empirical correction on dispersion interaction) and ab-initio (CASSCF, coupled clusters, and multireference configuration interaction including MRCI+Q) methods. The computational screening of reactions for different hydrocarbons (CH4, C2H6, C3H8, C2H4, and C2H2) as readily available carbon precursors for HCN formation, potential chemical transport agents, and for controlled carbon doping of deposited GaN was carried out with the B3LYP method in conjunction with basis sets up to aug-cc-pVTZ. The gas phase intermediates for the reactions in the Ga-hydrocarbon systems were predicted at different theory levels. The located π-complexes Ga…C2H2 and Ga…C2H4 were studied to determine a probable catalytic activity in reactions with NH3. A limited influence of the carbon-containing atmosphere was exhibited for the carbon doping of GaN crystal in the conventional GaN chemical vapor deposition (CVD) process with hydrocarbons injected in the gas phase. Our results provide a basis for experimental studies of GaN crystal growth with C2H4 and C2H2 as auxiliary carbon reagents for the Ga-NH3 and Ga-C-NH3 CVD systems and prerequisites for reactor design to enhance and control the PHVPE process through the HCN synthesis.

  9. Ultrafast electron-optical phonon scattering and quasiparticle lifetime in CVD-grown graphene.

    PubMed

    Shang, Jingzhi; Yu, Ting; Lin, Jianyi; Gurzadyan, Gagik G

    2011-04-26

    Ultrafast quasiparticle dynamics in graphene grown by chemical vapor deposition (CVD) has been studied by UV pump/white-light probe spectroscopy. Transient differential transmission spectra of monolayer graphene are observed in the visible probe range (400-650 nm). Kinetics of the quasiparticle (i.e., low-energy single-particle excitation with renormalized energy due to electron-electron Coulomb, electron-optical phonon (e-op), and optical phonon-acoustic phonon (op-ap) interactions) was monitored with 50 fs resolution. Extending the probe range to near-infrared, we find the evolution of quasiparticle relaxation channels from monoexponential e-op scattering to double exponential decay due to e-op and op-ap scattering. Moreover, quasiparticle lifetimes of mono- and randomly stacked graphene films are obtained for the probe photon energies continuously from 1.9 to 2.3 eV. Dependence of quasiparticle decay rate on the probe energy is linear for 10-layer stacked graphene films. This is due to the dominant e-op intervalley scattering and the linear density of states in the probed electronic band. A dimensionless coupling constant W is derived, which characterizes the scattering strength of quasiparticles by lattice points in graphene.

  10. Agreement between ethnicity recorded in two New Zealand health databases: effects of discordance on cardiovascular outcome measures (PREDICT CVD3).

    PubMed

    Marshall, Roger J; Zhang, Zhongqian; Broad, Joanna B; Wells, Sue

    2007-06-01

    To assess agreement between ethnicity as recorded by two independent databases in New Zealand, PREDICT and the National Health Index (NHI), and to assess sensitivity of ethnic-specific measures of health outcomes to either ethnicity record. Patients assessed using PREDICT form the study cohort. Ethnicity was recorded for PREDICT and an associated NHI ethnicity code was identified by merge-match linking on an encrypted NHI number. Agreement between ethnicity measures was assessed by kappa scores and scaled rectangle diagrams. A cohort of 18,239 individuals was linked in both PREDICT and NHI databases. The agreement between ethnicity classifications was reasonably good, with overall kappa coefficient of 0.82. There was better agreement for women than men and agreement improved with age and with time since the PREDICT system has been operational. Ethnic-specific cardiovascular (CVD) hospital admission rates were sensitive to ethnicity coding by NHI or PREDICT; rate ratios for ethnic groups, relative to European, based on PREDICT were attenuated towards the null relative to the NHI classification. Agreement between ethnicity was moderately good. Discordances that do exist do not have a substantial effect on prevalence-based measures of effect; however, they do on measurement of the admission of CVD. Different categorisations of ethnicity data from routine (and other) databases can lead to different ethnic-specific estimates of epidemiological effects. There is an imperative to record ethnicity in a rational, systematic and consistent way.

  11. Enhanced photoresponse characteristics of transistors using CVD-grown MoS2/WS2 heterostructures

    NASA Astrophysics Data System (ADS)

    Shan, Junjie; Li, Jinhua; Chu, Xueying; Xu, Mingze; Jin, Fangjun; Fang, Xuan; Wei, Zhipeng; Wang, Xiaohua

    2018-06-01

    Semiconductor heterostructures based on transition metal dichalcogenides provide a broad platform to research two-dimensional nanomaterials and design atomically thin devices for fundamental and applied interests. The MoS2/WS2 heterostructure was prepared on SiO2/Si substrate by chemical vapor deposition (CVD) in our research. And the optical properties of the heterostructure was characterized by Raman and photoluminescence (PL) spectroscopy. The similar 2 orders of magnitude decrease of PL intensity in MoS2/WS2 heterostructures was tested, which is attribute to the electrical and optical modulation effects are connected with the interfacial charge transfer between MoS2 and WS2 films. Using MoS2/WS2 heterostructure as channel material of the phototransistor, we demonstrated over 50 folds enhanced photoresponsivity of multilayer MoS2 field-effect transistor. The results indicate that the MoS2/WS2 films can be a promising heterostructure material to enhance the photoresponse characteristics of MoS2-based phototransistors.

  12. Flexible low-power RF nanoelectronics in the GHz regime using CVD MoS2

    NASA Astrophysics Data System (ADS)

    Yogeesh, Maruthi

    Two-dimensional (2D) materials have attracted substantial interest for flexible nanoelectronics due to the overall device mechanical flexibility and thickness scalability for high mechanical performance and low operating power. In this work, we demonstrate the first MoS2 RF transistors on flexible substrates based on CVD-grown monolayers, featuring record GHz cutoff frequency (5.6 GHz) and saturation velocity (~1.8×106 cm/s), which is significantly superior to contemporary organic and metal oxide thin-film transistors. Furthermore, multicycle three-point bending results demonstrated the electrical robustness of our flexible MoS2 transistors after 10,000 cycles of mechanical bending. Additionally, basic RF communication circuit blocks such as amplifier, mixer and wireless AM receiver have been demonstrated. These collective results indicate that MoS2 is an ideal advanced semiconducting material for low-power, RF devices for large-area flexible nanoelectronics and smart nanosystems owing to its unique combination of large bandgap, high saturation velocity and high mechanical strength.

  13. New CVD-based method for the growth of high-quality crystalline zinc oxide layers

    NASA Astrophysics Data System (ADS)

    Huber, Florian; Madel, Manfred; Reiser, Anton; Bauer, Sebastian; Thonke, Klaus

    2016-07-01

    High-quality zinc oxide (ZnO) layers were grown using a new chemical vapour deposition (CVD)-based low-cost growth method. The process is characterized by total simplicity, high growth rates, and cheap, less hazardous precursors. To produce elementary zinc vapour, methane (CH4) is used to reduce a ZnO powder. By re-oxidizing the zinc with pure oxygen, highly crystalline ZnO layers were grown on gallium nitride (GaN) layers and on sapphire substrates with an aluminum nitride (AlN) nucleation layer. Using simple CH4 as precursor has the big advantage of good controllability and the avoidance of highly toxic gases like nitrogen oxides. In photoluminescence (PL) measurements the samples show a strong near-band-edge emission and a sharp line width at 5 K. The good crystal quality has been confirmed in high resolution X-ray diffraction (HRXRD) measurements. This new growth method has great potential for industrial large-scale production of high-quality single crystal ZnO layers.

  14. Thermal chemical vapor deposition (T-CVD) growth of carbon nanotubes on different metallic underlayers

    NASA Astrophysics Data System (ADS)

    Kim, S. M.; Gangloff, L.

    2011-06-01

    The synthesis of carbon nanotubes (CNTs) on various substrates by thermal chemical vapor deposition (T-CVD) (500-800 °C) is described. C 2H 2 (98% purity) is used as the carbon feedstock and the metallic underlayers, i.e., AlCu, Cu, Ag, Ta, and NiV are used. A crucial component is the insertion (or inclusion) of an Al layer between the metal and the catalyst, which then leads to the effective growth of CNTs. The types of CNTs (single or multi walled) could be dependent on the diameter of Al xO y nanoparticles that are formed during the annealing process. In situ mass spectroscopy reveals that the increase in CO 2 and H 2O with temperature, during the growth, could be correlated to the formation of longer CNTs (∼2 μm) on NiV and Ta due to their etching effects (i.e. C+CO 2→2CO and C+H 2O→CO+H 2).

  15. Preferential orientation of NV defects in CVD diamond films grown on (113)-oriented substrates

    NASA Astrophysics Data System (ADS)

    Lesik, M.; Plays, T.; Tallaire, A.; Achard, J.; Brinza, O.; William, L.; Chipaux, M.; Toraille, L.; Debuisschert, T.; Gicquel, A.; Roch, J. F.; Jacques, V.

    2015-06-01

    Thick CVD diamond layers were successfully grown on (113)-oriented substrates. They exhibited smooth surface morphologies and a crystalline quality comparable to (100) electronic grade material, and much better than (111)-grown layers. High growth rates (15-50 {\\mu}m/h) were obtained while nitrogen doping could be achieved in a fairly wide range without seriously imparting crystalline quality. Electron spin resonance measurements were carried out to determine NV centers orientation and concluded that one specific orientation has an occurrence probability of 73 % when (100)-grown layers show an equal distribution in the 4 possible directions. A spin coherence time of around 270 {\\mu}s was measured which is equivalent to that reported for material with similar isotopic purity. Although a higher degree of preferential orientation was achieved with (111)-grown layers (almost 100 %), the ease of growth and post-processing of the (113) orientation make it a potentially useful material for magnetometry or other quantum mechanical applications.

  16. Method and apparatus for removing and preventing window deposition during photochemical vapor deposition (photo-CVD) processes

    DOEpatents

    Tsuo, S.; Langford, A.A.

    1989-03-28

    Unwanted build-up of the film deposited on the transparent light-transmitting window of a photochemical vacuum deposition (photo-CVD) chamber is eliminated by flowing an etchant into the part of the photolysis region in the chamber immediately adjacent the window and remote from the substrate and from the process gas inlet. The respective flows of the etchant and the process gas are balanced to confine the etchant reaction to the part of the photolysis region proximate to the window and remote from the substrate. The etchant is preferably one that etches film deposit on the window, does not etch or affect the window itself, and does not produce reaction by-products that are deleterious to either the desired film deposited on the substrate or to the photolysis reaction adjacent the substrate. 3 figs.

  17. Method and apparatus for removing and preventing window deposition during photochemical vapor deposition (photo-CVD) processes

    DOEpatents

    Tsuo, Simon; Langford, Alison A.

    1989-01-01

    Unwanted build-up of the film deposited on the transparent light-transmitting window of a photochemical vacuum deposition (photo-CVD) chamber is eliminated by flowing an etchant into the part of the photolysis region in the chamber immediately adjacent the window and remote from the substrate and from the process gas inlet. The respective flows of the etchant and the process gas are balanced to confine the etchant reaction to the part of the photolysis region proximate to the window and remote from the substrate. The etchant is preferably one that etches film deposit on the window, does not etch or affect the window itself, and does not produce reaction by-products that are deleterious to either the desired film deposited on the substrate or to the photolysis reaction adjacent the substrate.

  18. Effects of a fixed-dose combination strategy on adherence and risk factors in patients with or at high risk of CVD: the UMPIRE randomized clinical trial.

    PubMed

    Thom, Simon; Poulter, Neil; Field, Jane; Patel, Anushka; Prabhakaran, Dorairaj; Stanton, Alice; Grobbee, Diederick E; Bots, Michiel L; Reddy, K Srinath; Cidambi, Raghu; Bompoint, Severine; Billot, Laurent; Rodgers, Anthony

    2013-09-04

    Most patients with cardiovascular disease (CVD) do not take recommended medications long-term. The use of fixed-dose combinations (FDCs) improves adherence in several clinical areas. Previous trials of cardiovascular FDCs have assessed short-term effects compared with placebo or no treatment. To assess whether FDC delivery of aspirin, statin, and 2 blood pressure-lowering agents vs usual care improves long-term adherence to indicated therapy and 2 major CVD risk factors, systolic blood pressure (SBP) and low-density lipoprotein cholesterol (LDL-C). The UMPIRE trial, a randomized, open-label, blinded-end-point trial among 2004 participants with established CVD or at risk of CVD enrolled July 2010-July 2011 in India and Europe. The trial follow-up concluded in July 2012. Participants were randomly assigned (1:1) to an FDC-based strategy (n=1002) containing either (1) 75 mg aspirin, 40 mg simvastatin, 10 mg lisinopril, and 50 mg atenolol or (2) 75 mg aspirin, 40 mg simvastatin, 10 mg lisinopril, and 12.5 mg hydrochlorothiazide or to usual care (n=1002). Adherence to medication (defined as self-reported use of antiplatelet, statin, and ≥2 BP-lowering medications) and changes in SBP and LDL-C from baseline. At baseline, mean BP was 137/78 mm Hg, LDL-C was 91.5 mg/dL, and 1233 (61.5%) of 2004 participants reported use of antiplatelet, statin, and 2 or more BP-lowering medications. Median follow-up was 15 months (interquartile range, 12-18 months). The FDC group had improved adherence vs usual care (86% vs 65%; relative risk [RR] of being adherent, 1.33; 95% CI, 1.26-1.41; P < .001) with concurrent reductions in SBP (-2.6 mm Hg; 95% CI, -4.0 to -1.1 mm Hg; P < .001) and LDL-C (-4.2 mg/dL; 95% CI, -6.6 to -1.9 mg/dL; P < .001) at the end of the study. Although there was consistency of effects across predefined subgroups, evidence existed of larger benefits in patients with lower adherence at baseline. In this subgroup of 727 participants (36%), adherence at

  19. Evidence-based new service package vs. routine service package for smoking cessation to prevent high risk patients from cardiovascular diseases (CVD): study protocol for randomized controlled trial

    PubMed Central

    2013-01-01

    Background Smoking cessation is a high-priority intervention to prevent CVD events and deaths in developing countries. While several interventions to stop smoking have been proved successful, the question of how to increase their effectiveness and practicality in developing countries remains. In this study, a newly devised evidence-based smoking cessation service package will be compared with the existing service in a randomized controlled trial within the community setting of Thailand. Method/Design This randomized control trial will recruit 440 current smokers at CVD risk because of being diabetic and/or hypertensive. Informed, consented participants will be randomly allocated into the new service-package arm and the routine service arm. The study will take place in the non-communicable disease clinics of the Maetha District Hospital, Lampang, northern Thailand. The new smoking-cessation service-package comprises (1) regular patient motivation and coaching from the same primary care nurse over a 3-month period; (2) monthly application of piCO + smokerlyzer to sustain motivation of smoker’s quitting attempt and provide positive feedback over a 3-month period; (3) assistance by an assigned family member; (4) nicotine replacement chewing gum to relieve withdrawal symptoms. This new service will be compared with the traditional routine service comprising the 5A approach in a 1-year follow-up. Participants who consent to participate in the study but refuse to attempt quitting smoking will be allocated to the non-randomized arm, where they will be just followed up and monitored. Primary outcome of the study is smoking cessation rate at 1-year follow-up proven by breath analysis measuring carbomonoxide in parts per million in expired air. Secondary outcomes are smoking cessation rate at the 6-month follow-up, blood pressure and heart rate, CVD risk according to the Framingham general cardiovascular risk score, CVD events and deaths at the 12-month follow-up, and

  20. Age-Dependent Association among Helicobacter pylori Infection, Serum Pepsinogen Levels and Immune Response of Children to Live Oral Cholera Vaccine CVD 103-HgR

    PubMed Central

    Muhsen, Khitam; Lagos, Rosanna; Reymann, Mardi K.; Graham, David Y.; Pasetti, Marcela F.; Levine, Myron M.

    2014-01-01

    Background Through its effects on gastric secretion, we hypothesized that Helicobacter pylori infection may influence oral immunization. Accordingly, we examined the association between H. pylori infection, serum pepsinogen (PG) (measures for H. pylori gastritis) and vibriocidal antibody (a correlate of protection) seroconversion following oral immunization with CVD 103-HgR live cholera vaccine among children of different ages. Methods Sera from 422 Chilean children who were vaccinated with a single dose of CVD 103-HgR were tested by ELISA for serum IgG antibodies to H. pylori, PG I and PG II levels and antibodies to Shigella flexneri 2a lipopolysaccharide and hepatitis A virus (as markers of low socioeconomic status and exposure to enteric pathogens). Results The likelihood of vibriocidal antibody seroconversion following vaccination with CVD 103-HgR was significantly decreased in H. pylori-seropositive children age 6 months to 4 years with PG II>8 µg/L (adjusted OR 0.14 (95% CI 0.03–0.61; P = 0.009), and also in H. pylori seropositives with lower PG II level (adjusted OR 0.34, 95% CI 0.14–0.83; P = 0.017), compared to H. pylori-seronegatives. H. pylori-seropositive children aged 5–9 years with serum PG I>30 µg/L (indicating more severe gastritis) had higher odds of vibriocidal seroconversion than those with lower PG I levels (adjusted OR 4.41, 95%CI 1.26–15.38; P = 0.02). There was no significant association between exposures to S. flexneri 2a or hepatitis A virus and vibriocidal seroconversion. Conclusions As H. pylori gastritis progresses with increasing pediatric age in developing country venues, changes in gastric secretion ensue that we believe explain the observed differences in age-related immune responses to immunization with live oral cholera vaccine. The effect of H. pylori and changes of gastric acid secretion on the immunogenicity of various oral vaccines should be studied in different developing, transitional and industrialized

  1. Preparation of LiMn{sub 2}O{sub 4} cathode thin films for thin film lithium secondary batteries by a mist CVD process

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tadanaga, Kiyoharu, E-mail: tadanaga@chem.osakafu-u.ac.jp; Yamaguchi, Akihiro; Sakuda, Atsushi

    2014-05-01

    Highlights: • LiMn{sub 2}O{sub 4} thin films were prepared by using the mist CVD process. • An aqueous solution of lithium and manganese acetates is used for the precursor solution. • The cell with the LiMn{sub 2}O{sub 4} thin films exhibited a capacity of about 80 mAh/g. • The cell showed good cycling performance during 10 cycles. - Abstract: LiMn{sub 2}O{sub 4} cathode thin films for thin film lithium secondary batteries were prepared by using so-called the “mist CVD process”, employing an aqueous solution of lithium acetate and manganese acetate, as the source of Li and Mn, respectively. The aqueousmore » solution of starting materials was ultrasonically atomized to form mist particles, and mists were transferred by nitrogen gas to silica glass substrate to form thin films. FE-SEM observation revealed that thin films obtained by this process were dense and smooth, and thin films with a thickness of about 750 nm were obtained. The electrochemical cell with the thin films obtained by sintering at 700 °C exhibited a capacity of about 80 mAh/g, and the cell showed good cycling performance during 10 cycles.« less

  2. Cardiovascular disease (CVD) in the Norwegian Arctic. Air ambulance operations 1999-2009 and future challenges in the region.

    PubMed

    Norum, Jan

    2010-01-01

    Air ambulance operations in the Arctic have to deal with remote locations, long distances, rough weather conditions, seasonable darkness, and almost no alternative for landing. Despite these challenges, people expect high quality, specialist health care. This study aimed to analyse air ambulance operations due to cardiovascular disease (CVD) in the Arctic and employ the result as an instrument for future suggestions. Melting ice in the Arctic Sea opens new prospects for shipping, adventures, and oil/gas industry. In February 2010 all air ambulance operations performed in the Arctic during the period 1999 to 2009 were analysed. The population of this study covered patients with CVD. The state of emergency, state of seriousness (the National Advisory Committee on Aeronautics (NACA) scale was used), flight time, destination, and flying time were the main outcome measures. A total of 45 patients (myocardial infarction 31, angina pectoris 11, and heart failure 4 patients) were identified. There were 39 Norwegians and 6 people of other nationalities. The mean age was 57 years (range 43-83 years) Thirteen cardiac incidents occurred in June and July. Most cases (26 patients) were considered urgent or emergent, and the mean NACA score was 4 (range 3-6). The adjusted female/male ratio was 0.222, and the median flying time (one way) was 3 h 25 min (range 1 h-6 h 40 min). Four flights were delayed, and one fifth of patients were transported during the night (midnight to 8.00 AM). Air ambulance operations in the Arctic experience significant challenges. In the near future more shipping and polar adventure operations together with new oil and gas installations will increase the demand for health care support. Telemedical installations onboard vessels and rigs will be important for remote consultation and treatment.

  3. Wear Mechanism of Chemical Vapor Deposition (CVD) Carbide Insert in Orthogonal Cutting Ti-6Al-4V ELI at High Cutting Speed

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gusri, A. I.; Che Hassan, C. H.; Jaharah, A. G.

    2011-01-17

    The performance of Chemical Vapor Deposition (CVD) carbide insert with ISO designation of CCMT 12 04 04 LF, when turning titanium alloys was investigated. There were four layers of coating materials for this insert i.e.TiN-Al2O3-TiCN-TiN. The insert performance was evaluated based on the insert's edge resistant towards the machining parameters used at high cutting speed range of machining Ti-6Al-4V ELI. Detailed study on the wear mechanism at the cutting edge of CVD carbide tools was carried out at cutting speed of 55-95 m/min, feed rate of 0.15-0.35 mm/rev and depth of cut of 0.10-0.20 mm. Wear mechanisms such as abrasivemore » and adhesive were observed on the flank face. Crater wear due to diffusion was also observed on the rake race. The abrasive wear occurred more at nose radius and the fracture on tool were found at the feed rate of 0.35 mm/rev and the depth of cut of 0.20 mm. The adhesion wear takes place after the removal of the coating or coating delaminating. Therefore, adhesion or welding of titanium alloy onto the flank and rake faces demonstrates a strong bond at the workpiece-tool interface.« less

  4. Attenuated live cholera vaccine strain CVD 103-HgR elicits significantly higher serum vibriocidal antibody titers in persons of blood group O.

    PubMed Central

    Lagos, R; Avendaño, A; Prado, V; Horwitz, I; Wasserman, S; Losonsky, G; Cryz, S; Kaper, J B; Levine, M M

    1995-01-01

    Persons of blood group O are at increased risk of developing cholera gravis. In a randomized, placebo-controlled, double-blind safety-immunogenicity trial of live oral cholera vaccine CVD 103-HgR in 5- to 9-year-old Chilean children, vibriocidal antibody seroconversion (74% overall) did not differ by blood group. However, the reciprocal geometric mean titer (GMT) in blood group O vaccines (GMT = 486) was higher than that in non-O vaccines (GMT = 179) (P < 0.02). PMID:7822046

  5. Testing of a sCVD diamond detection system in the CROCUS reactor

    NASA Astrophysics Data System (ADS)

    Hursin, M.; Weiss, C.; Frajtag, P.; Lamirand, V.; Perret, G.; Kavrigin, P.; Pautz, A.; Griesmayer, E.

    2018-05-01

    The paper describes the testing of the NEUTON detection system into CROCUS, the zero-power reactor of the École Polytechnique Fédérale de Lausanne (EPFL). NEUTON is composed of a 4 mm × 4 mm sCVD diamond detector with a 6Li converter and the associated acquisition electronics. It is developed by CIVIDEC Instrumentation GmbH. The use of a diamond detector with converter in the mixed radiation field of a nuclear reactor is challenging because these detectors are sensitive to gamma-rays, fast neutrons and thermal neutrons through conversion in 6Li . In NEUTON, the rejection of gamma-rays is achieved in real time, via the analysis of the signal pulse shape from the detector. To do so, a few signal characteristics (amplitude, area and FWHM) are recorded in the integrated Field Programmable Gate Arrays (FPGA) of the system. This treatment does not induce any dead time. Measurements in CROCUS demonstrated for the first time the capability of a system like NEUTON to detect and separate fast neutrons, thermal neutrons, and gamma-rays. The system response was shown to be linear with respect to the reactor power (up to 35W) and its thermal sensitivity was found to be (3.5± 0.2)× 10^{-5} cps/nv.

  6. Growth of ZnOx:Al by high-throughput CVD at atmospheric pressure

    NASA Astrophysics Data System (ADS)

    Illiberi, A.; Simons, P. J. P. M.; Kniknie, B.; van Deelen, J.; Theelen, M.; Zeman, M.; Tijssen, M.; Zijlmans, W.; Steijvers, H. L. A. H.; Habets, D.; Janssen, A. C.; Beckers, E. H. A.

    2012-05-01

    Aluminum doped zinc oxide films (ZnOx:Al) have been deposited on a moving glass substrate by a metalorganic CVD process at atmospheric pressure in an in-line industrial type reactor. Tertiary-butanol has been used as an oxidant for diethylzinc and trimethylaluminium as the dopant gas. The effect of the deposition temperature (from 380 to 540 °C) on the deposition rate has been investigated by a numerical code, where a gas phase reaction among tertiary-butanol and diethylzinc is assumed to occur. The structural (crystallinity and morphology) properties of the films as a function of the deposition temperature have been analyzed by using X-ray diffraction and Scanning Electron Microscopy. A maximum growth rate of ˜11 nm/s was found at a deposition temperature of 480 °C, for which ZnOx:Al films show (002) preferential orientation, good crystalline quality and a naturally rough surface. ZnOx:Al films deposited at 480 °C are also highly conductive (R<10 Ω/□ for film thicknesses above 1050 nm) and transparent (>85% in the visible range). These films have been used as front transparent conductive oxide layers in p i n a-Si:H solar cells, achieving an initial efficiency approaching 8%.

  7. Morphological Evolution and Weak Interface Development within CVD-Zirconia Coating Deposited on Hi-Nicalon Fiber

    NASA Technical Reports Server (NTRS)

    Li, Hao; Lee, Jinil; Libera, Matthew R.; Lee, Woo Y.; Kebbede, Anteneh; Lance, Michael J.; Wang, Hongyu; Morscher, Gregory N.; Gray, Hugh R. (Technical Monitor)

    2002-01-01

    The phase contents and morphology of a ZrO2 fiber coating deposited at 1050 C on Hi-Nicalon(Tm) by chemical vapor deposition were examined as a function of deposition time from 5 to 120 min. The morphological evolution in the ZrO2 coating was correlated to the development of delamination within the ZrO2 coating. The delamination appears to occur as a result of: (1) continuous formation of tetragonal ZrO2 nuclei on the deposition surface; (2) martensitic transformation of the tetragonal phase to a monoclinic phase upon reaching a critical grain size; and (3) development of significant compressive hoop stresses due to the volume dilation associated with the transformation. Our observations suggest that it will be of critical importance to further understand and eventually control the nucleation and grain growth behavior of CVD ZrO2 and its phase transformation behavior for its potential applications for composites.

  8. Characterization of nephelium mutabile blume-like structure of carbon nanotubes prepared from palm oil by CVD method

    NASA Astrophysics Data System (ADS)

    Maryam, M.; Shamsudin, M. S.; Rusop, M.

    2017-09-01

    A new structure of carbon nanotube was produced from the Single furnace Aerosol-assisted Catalytic CVD (SFAACVD) method using Palm Oil (PO) as the precursor and Ferrocene (Fe) as the catalyst. A nephelium mutabile blume (rambutan)-like structure of CNTs was found from the black substance collected from the Alumina boat substrate placed inside the furnace. Temperature of furnace which was heated at 600 °C - 800 °C plays an important role in determining the formation of structure. The formation rambutan-like structure of CNTs was optimized at 700 °C and the samples collected were characterized by Field Emission Scanning Electron Microscope (FE-SEM) to obtain the surface morphologies. Raman Spectroscopy (RS) and Thermogravimetric Analysis (TGA) were then used to further study the Raman Spectra and purity of samples.

  9. Global burden of CVD: focus on secondary prevention of cardiovascular disease.

    PubMed

    Bansilal, Sameer; Castellano, José M; Fuster, Valentín

    2015-12-01

    Despite encouraging advances in prevention and treatment of atherothrombosis, cardiovascular disease (CVD) remains a major cause of deaths and disability worldwide and will continue to grow mainly due to the increase in incidence in low and middle income countries (LMIC). In Europe and the United States of America (USA), coronary heart disease (CHD) mortality rates have decreased since the mid-1990s due to improvements in acute care, however the prevalence of CHD is increasing largely in part due to the overall aging of the population, increased prevalence of cardiovascular (CV) risk factors, and improved survival of patients after a CV event. Data from clinical trials has consistently proven the efficacy of pharmacologic interventions with aspirin, statins, and blood pressure (BP)-lowering agents in reducing the risk of CV events and total mortality in the ever growing pool of patients in secondary prevention. However, large gaps between indicated therapy and prescribed medication can be observed worldwide, with very low rates of use of effective therapies in LMIC countries. Adherence to medication is very poor in chronic patients, especially those treated with multiple pharmacologic agents, and has been directly correlated to a greater incidence of recurrent CV events and increase in direct and indirect healthcare costs. In this article, we review the global burden of CV disease, status of secondary prevention therapy and major barriers for treatment adherence. Copyright © 2015 Elsevier B.V. All rights reserved.

  10. Challenges and Opportunities for the implementation of interventions to prevent and control CVD in low resource settings in Argentina

    PubMed Central

    Rubinstein, Adolfo; Irazola, Vilma E.; Poggio, Rosana; Gulayin, Pablo; Nejamis, Analía; Beratarrechea, Andrea

    2015-01-01

    In Argentina, Cardiovascular diseases are estimated to cause about 100,000 deaths and more than 250,000 coronary heart disease and stroke events annually, at a cost of more than one billion international dollars. Despite progress in the implementation of several programs to combat non-communicable diseases in Argentina over the last years, most health resources are still dedicated to infectious disease and maternal and child health. The Institute for Clinical Effectiveness and Health Policy, an independent academic institution affiliated to the University of Buenos Aires medical school, runs CESCAS (South American Centre of Excellence in Cardiovascular Health), a center devoted to epidemiological, implementation and policy research. At CESCAS there are three ongoing randomized clinical trials focused on implementation science: 1) A Mobile health intervention to prevent progression of pre-hypertension in poor urban settings in Argentina, Guatemala and Peru; 2) A Comprehensive Approach for Hypertension Prevention and Control in low-resource settings in Argentina; and 3) An Educational Approach to Improve Physician Effectiveness in the Detection, Treatment and Control for patients with Hypercholesterolemia and high Cardiovascular Disease (CVD) risk in low-resource settings in Argentina. All these studies involve the design and implementation of complex interventions to change behaviors of providers and patients. The rationale of each of the three studies, the design of the interventions and the evaluation of processes and outcomes are described in this article together with the barriers and enabling factors associated with implementation research studies. There is a strong need in Argentina and the region at large to build the health research capacity and infrastructure necessary to undertake implementation studies to translate evidence from research findings into improvements in health policy and practice to address CVD and their risk factors. PMID:25754563

  11. Report of work done for technical assistance agreement 1269 between Sandia National Laboratories and the Watkins-Johnson Company: Chemical reaction mechanisms for computational models of SiO{sub 2} CVD

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ho, P.; Johannes, J.; Kudriavtsev, V.

    The use of computational modeling to improve equipment and process designs for chemical vapor deposition (CVD) reactors is becoming increasingly common. Commercial codes are available that facilitate the modeling of chemically-reacting flows, but chemical reaction mechanisms must be separately developed for each system of interest. One f the products of the Watkins-Johnson Company (WJ) is a reactor marketed to semiconductor manufacturers for the atmospheric-pressure chemical vapor deposition (APCVD) of silicon oxide films. In this process, TEOS (tetraethoxysilane, Si(OC{sub 2}H{sub 5}){sub 4}) and ozone (O{sub 3}) are injected (in nitrogen and oxygen carrier gases) over hot silicon wafers that are beingmore » carried through the system on a moving belt. As part of their equipment improvement process, WJ is developing computational models of this tool. In this effort, they are collaborating with Sandia National Laboratories (SNL) to draw on Sandia`s experience base in understanding and modeling the chemistry of CVD processes.« less

  12. Growth of boron doped hydrogenated nanocrystalline cubic silicon carbide (3C-SiC) films by Hot Wire-CVD

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pawbake, Amit; Tata Institute of Fundamental Research, Colaba, Mumbai 400 005; Mayabadi, Azam

    Highlights: • Boron doped nc-3C-SiC films prepared by HW-CVD using SiH{sub 4}/CH{sub 4}/B{sub 2}H{sub 6}. • 3C-Si-C films have preferred orientation in (1 1 1) direction. • Introduction of boron into SiC matrix retard the crystallanity in the film structure. • Film large number of SiC nanocrystallites embedded in the a-Si matrix. • Band gap values, E{sub Tauc} and E{sub 04} (E{sub 04} > E{sub Tauc}) decreases with increase in B{sub 2}H{sub 6} flow rate. - Abstract: Boron doped nanocrystalline cubic silicon carbide (3C-SiC) films have been prepared by HW-CVD using silane (SiH{sub 4})/methane (CH{sub 4})/diborane (B{sub 2}H{sub 6}) gasmore » mixture. The influence of boron doping on structural, optical, morphological and electrical properties have been investigated. The formation of 3C-SiC films have been confirmed by low angle XRD, Raman spectroscopy, X-ray photoelectron spectroscopy (XPS), Fourier transform infra-red (FTIR) spectroscopy and high resolution-transmission electron microscopy (HR-TEM) analysis whereas effective boron doping in nc-3C-SiC have been confirmed by conductivity, charge carrier activation energy, and Hall measurements. Raman spectroscopy and HR-TEM analysis revealed that introduction of boron into the SiC matrix retards the crystallanity in the film structure. The field emission scanning electron microscopy (FE-SEM) and non contact atomic force microscopy (NC-AFM) results signify that 3C-SiC film contain well resolved, large number of silicon carbide (SiC) nanocrystallites embedded in the a-Si matrix having rms surface roughness ∼1.64 nm. Hydrogen content in doped films are found smaller than that of un-doped films. Optical band gap values, E{sub Tauc} and E{sub 04} decreases with increase in B{sub 2}H{sub 6} flow rate.« less

  13. Raman studied of undoped amorphous carbon thin film deposited by bias assisted-CVD

    NASA Astrophysics Data System (ADS)

    Ishak, A.; Fadzilah, A. N.; Dayana, K.; Saurdi, I.; Malek, M. F.; Nurbaya, Z.; Shafura, A. K.; Rusop, M.

    2018-05-01

    The undoped amorphous carbon thin film carbon was deposited at 200°C-350°C by bias assisted-CVD using palm oil as a precursor material. The effect of different substrate deposition temperatures on structural and electrical properties of undoped doped amorphous carbon film was discussed. The structural of undoped amorphous carbon films were correlated with Raman analysis through the evolution of D and G bands, Fourier spectra, and conductivity measurement. The spectral evolution observed showed the increase of upward shift of D and G peaks as substrate deposition temperatures increased. The spectral evolution observed at different substrate deposition temperatures show progressive formation of crystallites. It was predicted that small number of hydrogen is terminated with carbon at surface of thin film as shown by FTIR spectra since palm oil has high number of hydrogen (C67H127O8). These structural changes were further correlated with conductivity and the results obtained are discussed and compared. The conductivity is found in the range of 10-8 Scm-1. The increase of conductivity is correlated by the change of structural properties as correlated with characteristic parameters of Raman spectra including the position of G peak, full width at half maximum of G peak, and ID/IG and FTIR result.

  14. The effect of oat β-glucan on LDL-cholesterol, non-HDL-cholesterol and apoB for CVD risk reduction: a systematic review and meta-analysis of randomised-controlled trials.

    PubMed

    Ho, Hoang V T; Sievenpiper, John L; Zurbau, Andreea; Blanco Mejia, Sonia; Jovanovski, Elena; Au-Yeung, Fei; Jenkins, Alexandra L; Vuksan, Vladimir

    2016-10-01

    Oats are a rich source of β-glucan, a viscous, soluble fibre recognised for its cholesterol-lowering properties, and are associated with reduced risk of CVD. Our objective was to conduct a systematic review and meta-analysis of randomised-controlled trials (RCT) investigating the cholesterol-lowering potential of oat β-glucan on LDL-cholesterol, non-HDL-cholesterol and apoB for the risk reduction of CVD. MEDLINE, Embase, CINAHL and Cochrane CENTRAL were searched. We included RCT of ≥3 weeks of follow-up, assessing the effect of diets enriched with oat β-glucan compared with controlled diets on LDL-cholesterol, non-HDL-cholesterol or apoB. Two independent reviewers extracted data and assessed study quality and risk of bias. Data were pooled using the generic inverse-variance method with random effects models and expressed as mean differences with 95 % CI. Heterogeneity was assessed by the Cochran's Q statistic and quantified by the I 2-statistic. In total, fifty-eight trials (n 3974) were included. A median dose of 3·5 g/d of oat β-glucan significantly lowered LDL-cholesterol (-0·19; 95 % CI -0·23, -0·14 mmol/l, P<0·00001), non-HDL-cholesterol (-0·20; 95 % CI -0·26, -0·15 mmol/l, P<0·00001) and apoB (-0·03; 95 % CI -0·05, -0·02 g/l, P<0·0001) compared with control interventions. There was evidence for considerable unexplained heterogeneity in the analysis of LDL-cholesterol (I 2=79 %) and non-HDL-cholesterol (I 2=99 %). Pooled analyses showed that oat β-glucan has a lowering effect on LDL-cholesterol, non-HDL-cholesterol and apoB. Inclusion of oat-containing foods may be a strategy for achieving targets in CVD reduction.

  15. Lateral gas phase diffusion length of boron atoms over Si/B surfaces during CVD of pure boron layers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mohammadi, V., E-mail: V.Mohammadi@tudelft.nl; Nihtianov, S.

    The lateral gas phase diffusion length of boron atoms, L{sub B}, along silicon and boron surfaces during chemical vapor deposition (CVD) using diborane (B{sub 2}H{sub 6}) is reported. The value of L{sub B} is critical for reliable and uniform boron layer coverage. The presented information was obtained experimentally and confirmed analytically in the boron deposition temperature range from 700 °C down to 400 °C. For this temperature range the local loading effect of the boron deposition is investigated on the micro scale. A L{sub B} = 2.2 mm was determined for boron deposition at 700 °C, while a L{sub B}more » of less than 1 mm was observed at temperatures lower than 500 °C.« less

  16. The Heartfile Lodhran CVD prevention project--end of project evaluation.

    PubMed

    Nishtar, Sania; Badar, Asma; Kamal, Mohammad Umer; Iqbal, Azhar; Bajwa, Rashid; Shah, Tauqeer; Larik, Zahid; Karim, Fazle; Mehmood, Mahmood ul Hassan; Jehangir, Haroon; Azam, Syed Iqbal; Mirza, Yasir Abbas; Khan, Shahzad Ali; Qayyum, Aamra; Aqeel, Fauzia; Bakir, Abdul; Rahim, Ejaz

    2007-01-01

    Mainstream preventive interventions often fail to reach poor populations with a high risk of cardiovascular diseases (CVDs) in Pakistan. A community-based CVD primary prevention project aimed at developing approaches to reduce risk factors in such populations was established by Heartfile in collaboration with the National Rural Support Program in the district of Lodhran. The project implemented a range of activities integrated with existing social and health service mechanisms during a three year intervention period 2000/01-03/04. These were targeted in 4 key settings: community health education, mass media interventions, training of health professionals and health education through Lady Health Workers. The project received support from the Department for International Development, U.K. At the community level, a pre-test-post-test quasi-experimental design was used for examining project outcomes related to the community component of the intervention. Pre and post-intervention (training) evaluations were conducted involving all health care providers in randomly selected workshops in order to determine baseline levels of knowledge and the impact of training on knowledge level. In order to assess practices of physician and non-physician health care providers patient interviews, with control comparisons were conducted at each health care facility. Significant positive changes were observed in knowledge levels at a community level in the district of intervention compared with baseline knowledge levels particularly in relation to a heart healthy diet, beneficial level of physical activity, the causes of high blood pressure and heart attack and the effects of high blood pressure and active and passive smoking on health. Significant changes in behaviors at a practice level were not shown in the district of intervention. However the project played a critical role in spurring national action for the prevention and control of non-communicable diseases and introducing

  17. Ti:Pt:Au:Ni thin-film CVD diamond sensor ability for charged particle detection.

    PubMed

    Kasiwattanawut, Haruetai; Tchouaso, Modeste Tchakoua; Prelas, Mark A

    2018-05-22

    This work demonstrates the development of diamond sensors with reliable contacts using a new metallization formula, which can operate under high-pressure gas environment. The metallization was created using thin film layers of titanium, platinum, gold and nickel deposited on a single crystal electronic grade CVD diamond chip. The contacts were 2 mm in diameter with thickness of 50/5/20/150 nm of Ti:Pt:Au:Ni. The optimum operating voltage of the sensor was determined from the current-voltage measurements. The sensor was calibrated with 239 Pu and 241 Am alpha radiation sources at 300 V. The energy resolution of the Ti:Pt:Au:Ni diamond sensor was determined to be 7.6% at 5.2 MeV of 239 Pu and 2.2% at 5.48 MeV of 241 Am. The high-pressure gas loading environment under which this sensor was used is discussed. Specifically, experimental observations are described using hydrogen loading of nickel as a means of initiating low energy nuclear reactions. No neutrons, electrons, ions or other ionizing radiations were observed in these experiments. Copyright © 2018 Elsevier Ltd. All rights reserved.

  18. Large-Area CVD-Grown Sub-2 V ReS2 Transistors and Logic Gates.

    PubMed

    Dathbun, Ajjiporn; Kim, Youngchan; Kim, Seongchan; Yoo, Youngjae; Kang, Moon Sung; Lee, Changgu; Cho, Jeong Ho

    2017-05-10

    We demonstrated the fabrication of large-area ReS 2 transistors and logic gates composed of a chemical vapor deposition (CVD)-grown multilayer ReS 2 semiconductor channel and graphene electrodes. Single-layer graphene was used as the source/drain and coplanar gate electrodes. An ion gel with an ultrahigh capacitance effectively gated the ReS 2 channel at a low voltage, below 2 V, through a coplanar gate. The contact resistance of the ion gel-gated ReS 2 transistors with graphene electrodes decreased dramatically compared with the SiO 2 -devices prepared with Cr electrodes. The resulting transistors exhibited good device performances, including a maximum electron mobility of 0.9 cm 2 /(V s) and an on/off current ratio exceeding 10 4 . NMOS logic devices, such as NOT, NAND, and NOR gates, were assembled using the resulting transistors as a proof of concept demonstration of the applicability of the devices to complex logic circuits. The large-area synthesis of ReS 2 semiconductors and graphene electrodes and their applications in logic devices open up new opportunities for realizing future flexible electronics based on 2D nanomaterials.

  19. Direct dry transfer of CVD graphene to an optical substrate by in situ photo-polymerization

    NASA Astrophysics Data System (ADS)

    Kessler, Felipe; Muñoz, Pablo A. R.; Phelan, Ciaran; Romani, Eric C.; Larrudé, Dunieskys R. G.; Freire, Fernando L.; Thoroh de Souza, Eunézio A.; de Matos, Christiano J. S.; Fechine, Guilhermino J. M.

    2018-05-01

    Here, we report on a method that allows graphene produced by chemical vapor deposition (CVD) to be directly transferred to an optically transparent photo resin, by in situ photo-polymerization of the latter, with high efficiency and low contamination. Two photocurable resins, A and B, with different viscosities but essentially the same chemical structure, were used. Raman spectroscopy and surface energy results show that large continuous areas of graphene were transferred with minimal defects to the lower viscosity resin (B), due to the better contact between the resin and graphene. As a proof-of-principle optical experiment, graphene on the polymeric substrate was subjected to high-intensity femtosecond infrared pulses and third-harmonic generation was observed with no noticeable degradation of the sample. A sheet third-order susceptibility χ (3) = 0.71 ×10-28m3V-2 was obtained, matching that of graphene on a glass substrate. These results indicate the suitability of the proposed transfer method, and of the photo resin, for the production of nonlinear photonic components and devices.

  20. The vertical growth of MoS2 layers at the initial stage of CVD from first-principles

    NASA Astrophysics Data System (ADS)

    Xue, Xiong-Xiong; Feng, Yexin; Chen, Keqiu; Zhang, Lixin

    2018-04-01

    Chemical vapor deposition (CVD) is the highly preferred method for mass production of transition metal dichalcogenide (TMD) layers, yet the atomic-scale knowledge is still lacking about the nucleation and growth. In this study, by using first-principles calculations, we show that, on Au(111) surface, one-dimensional (1D) MoxSy chains are first formed by coalescing of smaller feeding species and are energetically favored at the early stage of nucleation. Two-dimensional (2D) layers can be stabilized only after the number of Mo atoms exceeds ˜12. A vertical growth mode is revealed which accomplishes the structural transformation from the 1D chains to the 2D layers for the clusters while growing. The competition between intralayer and interlayer interactions is the key. These findings serve as new insights for better understanding the atomistic mechanism of the nucleation and growth of TMDs on the surface.

  1. Strain Gauges Based on CVD Graphene Layers and Exfoliated Graphene Nanoplatelets with Enhanced Reproducibility and Scalability for Large Quantities

    PubMed Central

    Yokaribas, Volkan; Schneider, Daniel S.; Friebertshäuser, Philipp; Lemme, Max C.; Fritzen, Claus-Peter

    2017-01-01

    The two-dimensional material graphene promises a broad variety of sensing activities. Based on its low weight and high versatility, the sensor density can significantly be increased on a structure, which can improve reliability and reduce fluctuation in damage detection strategies such as structural health monitoring (SHM). Moreover; it initializes the basis of structure–sensor fusion towards self-sensing structures. Strain gauges are extensively used sensors in scientific and industrial applications. In this work, sensing in small strain fields (from −0.1% up to 0.1%) with regard to structural dynamics of a mechanical structure is presented with sensitivities comparable to bulk materials by measuring the inherent piezoresistive effect of graphene grown by chemical vapor deposition (CVD) with a very high aspect ratio of approximately 4.86 × 108. It is demonstrated that the increasing number of graphene layers with CVD graphene plays a key role in reproducible strain gauge application since defects of individual layers may become less important in the current path. This may lead to a more stable response and, thus, resulting in a lower scattering.. Further results demonstrate the piezoresistive effect in a network consisting of liquid exfoliated graphene nanoplatelets (GNP), which result in even higher strain sensitivity and reproducibility. A model-assisted approach provides the main parameters to find an optimum of sensitivity and reproducibility of GNP films. The fabricated GNP strain gauges show a minimal deviation in PRE effect with a GF of approximately 5.6 and predict a linear electromechanical behaviour up to 1% strain. Spray deposition is used to develop a low-cost and scalable manufacturing process for GNP strain gauges. In this context, the challenge of reproducible and reliable manufacturing and operating must be overcome. The developed sensors exhibit strain gauges by considering the significant importance of reproducible sensor performances and

  2. C_7F_16/He rf plasma CVD of a-C:F films

    NASA Astrophysics Data System (ADS)

    Hokoi, Kohji; Akazawa, Masamichi; Sugawara, Hirotake; Sakai, Yosuke

    2000-10-01

    Fluorinated carbon is one of the most promissing materials with low dielectric constant ɛr and high dielectric strength V_b. We have deposited a-C:F films by rf (13.56 MHz) plasma enhanced CVD method using the following liquid materials; C_7F_16, (C_3F_7)_3N/(C_4F_9)_3N and C_8F_18/C_8F_16O.(C. P. Lungu et al.), Jpn. J. Appl. Phys. 38, L1544--6 (1999) The films showed ɛr values in a range of 1.9--3.0 and V_b>2 MV/cm. In this work, we added He (3 Pa) to C_7F_16 (60 Pa) plasmas, expecting that He atoms in the metastable excited state (He*, 19.8 eV) would promote C_7F_16 decomposition in gas phase or activation of the film surface during deposition. The films with the thickness up to 2300 nm were deposited on unheated Si substrate with an rf power of 100 W. The deposition rate derived from the film thickness measurement by SEM and ellipsometry was about 230 nm/min. This value is roughly two times as large as that of the films deposited by C_7F_16 (60 Pa) plasmas without He. We discuss the mechanism that leads to such a significant increase in the deposition rate.

  3. Synthesis of carbon nanotubes from palm oil on stacking and non-stacking substrate by thermal-CVD method

    NASA Astrophysics Data System (ADS)

    Robaiah, M.; Rusop, M.; Abdullah, S.; Khusaimi, Z.; Azhan, H.; Fadzlinatul, M. Y.; Salifairus, M. J.; Asli, N. A.

    2018-05-01

    Palm oil has been used as the carbon source to synthesize carbon nanotubes (CNTs) on silicon substrates using the thermal chemical vapor deposition (CVD) method. Meanwhile, silicon has been applied using two techniques, which are stacked technique and non-stacked technique. The CNTs were grown at the constant time of 30 minutes with various synthesis temperatures of 750 °C, 850 °C and 950 °C. The CNTs were characterized using micro-Raman spectroscopy and field emission scanning electron microscopy (FESEM). It was found that the density, growth rate, diameter and length of the CNTs produced were affected by the synthesis temperature. Moreover, the structure slightly changes were observed between CNTs obtained in SS and NSS. The synthesize temperature of 750 °C was considered as the suitable temperature for the production of CNTs due to low ID/IG ratio, which for stacked is 0.89 and non-stacked are 0.90. The possible explanation for the different morphology of the produced CNTs was also discussed.

  4. Structure and wettability property of the growth and nucleation surfaces of thermally treated freestanding CVD diamond films

    NASA Astrophysics Data System (ADS)

    Pei, Xiaoqiang; Cheng, Shaoheng; Ma, Yibo; Wu, Danfeng; Liu, Junsong; Wang, Qiliang; Yang, Yizhou; Li, Hongdong

    2015-08-01

    This paper reports the surface features and wettability properties of the (1 0 0)-textured freestanding chemical vapor deposited (CVD) diamond films after thermal exposure in air at high temperature. Thermal oxidation at proper conditions eliminates selectively nanodiamonds and non-diamond carbons in the films. The growth side of the films contains (1 0 0)-oriented micrometer-sized columns, while its nucleation side is formed of nano-sized tips. The examined wettability properties of the as-treated diamond films reveal a hydrophilicity and superhydrophilicity on the growth surface and nucleation surface, respectively, which is determined by oxygen termination and geometry structure of the surface. When the surface termination is hydrogenated, the wettability of nucleation side converted from superhydrophilicity to high hydrophobicity, while the hydrophilicity of the growth side does not change significantly. The findings open a possibility for realizing freestanding diamond films having not only novel surface structures but also multifunction applications, especially proposed on the selected growth side or nucleation side in one product.

  5. Efficient etching-free transfer of high quality, large-area CVD grown graphene onto polyvinyl alcohol films

    NASA Astrophysics Data System (ADS)

    Marta, Bogdan; Leordean, Cosmin; Istvan, Todor; Botiz, Ioan; Astilean, Simion

    2016-02-01

    Graphene transfer is a procedure of paramount importance for the production of graphene-based electronic devices. The transfer procedure can affect the electronic properties of the transferred graphene and can be detrimental for possible applications both due to procedure induced defects which can appear and due to scalability of the method. Hence, it is important to investigate new transfer methods for graphene that are less time consuming and show great promise. In the present study we propose an efficient, etching-free transfer method that consists in applying a thin polyvinyl alcohol layer on top of the CVD grown graphene on Cu and then peeling-off the graphene onto the polyvinyl alcohol film. We investigate the quality of the transferred graphene before and after the transfer, using Raman spectroscopy and imaging as well as optical and atomic force microscopy techniques. This simple transfer method is scalable and can lead to complete transfer of graphene onto flexible and transparent polymer support films without affecting the quality of the graphene during the transfer procedure.

  6. The association between a vegetarian diet and cardiovascular disease (CVD) risk factors in India: the Indian Migration Study.

    PubMed

    Shridhar, Krithiga; Dhillon, Preet Kaur; Bowen, Liza; Kinra, Sanjay; Bharathi, Ankalmadugu Venkatsubbareddy; Prabhakaran, Dorairaj; Reddy, Kolli Srinath; Ebrahim, Shah

    2014-01-01

    Studies in the West have shown lower cardiovascular disease (CVD) risk among people taking a vegetarian diet, but these findings may be confounded and only a minority selects these diets. We evaluated the association between vegetarian diets (chosen by 35%) and CVD risk factors across four regions of India. Study participants included urban migrants, their rural siblings and urban residents, of the Indian Migration Study from Lucknow, Nagpur, Hyderabad and Bangalore (n = 6555, mean age-40.9 yrs). Information on diet (validated interviewer-administered semi-quantitative food frequency questionnaire), tobacco, alcohol, physical history, medical history, as well as blood pressure, fasting blood and anthropometric measurements were collected. Vegetarians ate no eggs, fish, poultry or meat. Using robust standard error multivariate linear regression models, we investigated the association of vegetarian diets with blood cholesterol, low density lipoprotein (LDL), high density lipoprotein (HDL), triglycerides, fasting blood glucose (FBG), systolic (SBP) and diastolic blood pressure (DBP). Vegetarians (32.8% of the study population) did not differ from non-vegetarians with respect to age, use of smokeless tobacco, body mass index, and prevalence of diabetes or hypertension. Vegetarians had a higher standard of living and were less likely to smoke, drink alcohol (p<0.0001) and were less physically active (p = 0.04). In multivariate analysis, vegetarians had lower levels of total cholesterol (β =  -0.1 mmol/L (95% CI: -0.03 to -0.2), p = 0.006), triglycerides (β =  -0.05 mmol/L (95% CI: -0.007 to -0.01), p = 0.02), LDL (β =  -0.06 mmol/L (95% CI: -0.005 to -0.1), p = 0.03) and lower DBP (β =  -0.7 mmHg (95% CI: -1.2 to -0.07), p = 0.02). Vegetarians also had decreases in SBP (β =  -0.9 mmHg (95% CI: -1.9 to 0.08), p = 0.07) and FBG level (β =  -0.07 mmol/L (95% CI: -0.2 to 0.01), p = 0.09) when compared to non-vegetarians. We found beneficial association of

  7. High-rate deposition of LiNb 1- xTa xO 3 films by thermal plasma spray CVD

    NASA Astrophysics Data System (ADS)

    Majima, T.; Yamamoto, H.; Kulinich, S. A.; Terashima, K.

    2000-12-01

    LiNb 1- xTa xO 3 films were prepared by a thermal plasma spray CVD method using liquid source materials. Preferentially (0 0 1)-oriented LiNb 1- xTa xO 3 films with satisfactory in-plane and out-of-plane alignment were fabricated on sapphire (0 0 1) substrates. The full-width at half-maximum (FWHM) of the (0 0 6) rocking curve could achieve 0.12°, which was comparable with those of LiNbO 3 and LiTaO 3 films prepared by other conventional vapor-phase deposition methods. The deposition rate was up to 0.07 μm/min, which was 5-40 times faster than those for most other conventional vapor-phase deposition methods. From inductively coupled plasma atomic emission spectroscopy analysis, x values of these films were estimated to be 0.36-0.49.

  8. Controlling the ripple density and heights: a new way to improve the electrical performance of CVD-grown graphene.

    PubMed

    Park, Won-Hwa; Jo, Insu; Hong, Byung Hee; Cheong, Hyeonsik

    2016-05-14

    We report a new way to enhance the electrical performances of large area CVD-grown graphene through controlling the ripple density and heights after transfer onto SiO2/Si substrates by employing different cooling rates during fabrication. We find that graphene films prepared with a high cooling rate have reduced ripple density and heights and improved electrical characteristics such as higher electron/hole mobilities as well as reduced sheet resistance. The corresponding Raman analysis also shows a significant decrease of the defects when a higher cooling rate is employed. We suggest a model that explains the improved morphology of the graphene film obtained with higher cooling rates. From these points of view, we can suggest a new pathway toward a relatively lower density and heights of ripples in order to reduce the flexural phonon-electron scattering effect, leading to higher lateral carrier mobilities.

  9. CVD growth and properties of boron phosphide on 3C-SiC

    NASA Astrophysics Data System (ADS)

    Padavala, Balabalaji; Frye, C. D.; Wang, Xuejing; Raghothamachar, Balaji; Edgar, J. H.

    2016-09-01

    Improving the crystalline quality of boron phosphide (BP) is essential for realizing its full potential in semiconductor device applications. In this study, 3C-SiC was tested as a substrate for BP epitaxy. BP films were grown on 3C-SiC(100)/Si, 3C-SiC(111)/Si, and 3C-SiC(111)/4H-SiC(0001) substrates in a horizontal chemical vapor deposition (CVD) system. Films were produced with good crystalline orientation and morphological features in the temperature range of 1000-1200 °C using a PH3+B2H6+H2 mixture. Rotational twinning was absent in the BP due to the crystal symmetry-matching with 3C-SiC. Confocal 3D Raman imaging of BP films revealed primarily uniform peak shift and peak widths across the scanned area, except at defects on the surface. Synchrotron white beam X-ray topography showed the epitaxial relationship between BP and 3C-SiC was (100) 〈 011 〉 BP||(100) 〈 011 〉 3C-SiC and (111) 〈 11 2 ̅ 〉 BP||(111) 〈 11 2 ̅ 〉 3C-SiC. Scanning electron microscopy, Raman spectroscopy and X-ray diffraction analysis indicated residual tensile strain in the films and improved crystalline quality at temperatures below 1200 °C. These results indicated that BP properties could be further enhanced by employing high quality bulk 3C-SiC or 3C-SiC epilayers on 4H-SiC substrates.

  10. CVD growth and properties of boron phosphide on 3C-SiC

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Padavala, Balabalaji; Frye, C. D.; Wang, Xuejing

    Improving the crystalline quality of boron phosphide (BP) is essential for realizing its full potential in semiconductor device applications. In this study, 3C-SiC was tested as a substrate for BP epitaxy. BP films were grown on 3C-SiC(100)/Si, 3C-SiC(111)/Si, and 3C-SiC(111)/4H-SiC(0001) substrates in a horizontal chemical vapor deposition (CVD) system. Films were produced with good crystalline orientation and morphological features in the temperature range of 1000–1200 °C using a PH3+B2H6+H2 mixture. Rotational twinning was absent in the BP due to the crystal symmetry-matching with 3C-SiC. Confocal 3D Raman imaging of BP films revealed primarily uniform peak shift and peak widths acrossmore » the scanned area, except at defects on the surface. Synchrotron white beam X-ray topography showed the epitaxial relationship between BP and 3C-SiC was (100) <011>BP||(100) <011>3C-SiC and (111)View the MathML sourceBP||(111)View the MathML source3C-SiC. Scanning electron microscopy, Raman spectroscopy and X-ray diffraction analysis indicated residual tensile strain in the films and improved crystalline quality at temperatures below 1200 °C. These results indicated that BP properties could be further enhanced by employing high quality bulk 3C-SiC or 3C-SiC epilayers on 4H-SiC substrates.« less

  11. Children's Services: Partnerships for Success

    ERIC Educational Resources Information Center

    Diamant-Cohen, Betsy, Ed.

    2010-01-01

    Co-author of the popular titles "Booktalking Bonanza" and "The Early Literacy Kit", Betsy Diamant-Cohen brings together 18 examples of successful outreach partnerships that children's librarians and administrators can adapt to their own situations. Contributors from the U.S and Canada explain how they partnered with schools,…

  12. Evaluation of Factor V G1691A, prothrombin G20210A, Factor XIII V34L, MTHFR A1298C, MTHFR C677T and PAI-1 4G/5G genotype frequencies of patients subjected to cardiovascular disease (CVD) panel in south-east region of Turkey.

    PubMed

    Oztuzcu, Serdar; Ergun, Sercan; Ulaşlı, Mustafa; Nacarkahya, Gülper; Iğci, Yusuf Ziya; Iğci, Mehri; Bayraktar, Recep; Tamer, Ali; Çakmak, Ecir Ali; Arslan, Ahmet

    2014-06-01

    Cardiovascular disease (CVD) risk factors, such as arterial hypertension, obesity, dyslipidemia or diabetes mellitus, as well as CVDs, including myocardial infarction, coronary artery disease or stroke, are the most prevalent diseases and account for the major causes of death worldwide. In the present study, 4,709 unrelated patients subjected to CVD panel in south-east part of Turkey between the years 2010 and 2013 were enrolled and DNA was isolated from the blood samples of these patients. Mutation analyses were conducted using the real-time polymerase chain reaction method to screen six common mutations (Factor V G1691A, PT G20210A, Factor XIII V34L, MTHFR A1298C and C677T and PAI-1 -675 4G/5G) found in CVD panel. The prevalence of these mutations were 0.57, 0.25, 2.61, 13.78, 9.34 and 24.27 % in homozygous form, respectively. Similarly, the mutation percent of them in heterozygous form were 7.43, 3.44, 24.91, 44.94, 41.09 and 45.66%, respectively. No mutation was detected in 92 (1.95%) patients in total. Because of the fact that this is the first study to screen six common mutations in CVD panel in south-east region of Turkey, it has a considerable value on the diagnosis and treatment of these diseases. Upon the results of the present and previous studied a careful examination for these genetic variants should be carried out in thrombophilia screening programs, particularly in Turkish population.

  13. In-situ sensing using mass spectrometry and its use for run-to-run control on a W-CVD cluster tool

    NASA Astrophysics Data System (ADS)

    Gougousi, T.; Sreenivasan, R.; Xu, Y.; Henn-Lecordier, L.; Rubloff, G. W.; Kidder, , J. N.; Zafiriou, E.

    2001-01-01

    A 300 amu closed-ion-source RGA (Leybold-Inficon Transpector 2) sampling gases directly from the reactor of an ULVAC ERA-1000 cluster tool has been used for real time process monitoring of a W CVD process. The process involves H2 reduction of WF6 at a total pressure of 67 Pa (0.5 torr) to produce W films on Si wafers heated at temperatures around 350 °C. The normalized RGA signals for the H2 reagent depletion and the HF product generation were correlated with the W film weight as measured post-process with an electronic microbalance for the establishment of thin-film weight (thickness) metrology. The metrology uncertainty (about 7% for the HF product) was limited primarily by the very low conversion efficiency of the W CVD process (around 2-3%). The HF metrology was then used to drive a robust run-to-run control algorithm, with the deposition time selected as the manipulated (or controlled) variable. For that purpose, during a 10 wafer run, a systematic process drift was introduced as a -5 °C processing temperature change for each successive wafer, in an otherwise unchanged process recipe. Without adjustment of the deposition time the W film weight (thickness) would have declined by about 50% by the 10th wafer. With the aid of the process control algorithm, an adjusted deposition time was computed so as to maintain constant HF sensing signal, resulting in weight (thickness) control comparable to the accuracy of the thickness metrology. These results suggest that in-situ chemical sensing, and particularly mass spectrometry, provide the basis for wafer state metrology as needed to achieve run-to-run control. Furthermore, since the control accuracy was consistent with the metrology accuracy, we anticipate significant improvements for processes as used in manufacturing, where conversion rates are much higher (40-50%) and corresponding signals for metrology will be much larger.

  14. Comparing the cost-effectiveness of four novel risk markers for screening asymptomatic individuals to prevent cardiovascular disease (CVD) in the US population.

    PubMed

    van Kempen, Bob J H; Ferket, Bart S; Steyerberg, Ewout W; Max, Wendy; Myriam Hunink, M G; Fleischmann, Kirsten E

    2016-01-15

    High sensitivity CRP (hsCRP), coronary artery calcification on CT (CT calcium), carotid artery intima media thickness on ultrasound (cIMT) and ankle-brachial index (ABI) improve prediction of cardiovascular disease (CVD) risk, but the benefit of screening with these novel risk markers in the U.S. population is unclear. A microsimulation model evaluating lifelong cost-effectiveness for individuals aged 40-85 at intermediate risk of CVD, using 2003-2004 NHANES-III (N=3736), Framingham Heart Study, U.S. Vital Statistics, meta-analyses of independent predictive effects of the four novel risk markers and treatment effects was constructed. Using both an intention-to-treat (assumes adherence <100% and incorporates disutility from taking daily medications) and an as-treated (100% adherence and no disutility) analysis, quality adjusted life years (QALYs), lifetime costs (2014 US $), and incremental cost-effectiveness ratios (ICER in $/QALY gained) of screening with hsCRP, CT coronary calcium, cIMT and ABI were established compared with current practice, full adherence to current guidelines, and ubiquitous statin therapy. In the intention-to-treat analysis in men, screening with CT calcium was cost effective ($32,900/QALY) compared with current practice. In women, screening with hsCRP was cost effective ($32,467/QALY). In the as-treated analysis, statin therapy was both more effective and less costly than all other strategies for both men and women. When a substantial disutility from taking daily medication is assumed, screening men with CT coronary calcium is likely to be cost-effective whereas screening with hsCRP has value in women. The individual perceived disutility for taking daily medication should play a key role in the decision. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  15. Development Status of a CVD System to Deposit Tungsten onto UO2 Powder via the WCI6 Process

    NASA Technical Reports Server (NTRS)

    Mireles, O. R.; Kimberlin, A.; Broadway, J.; Hickman, R.

    2014-01-01

    Nuclear Thermal Propulsion (NTP) is under development for deep space exploration. NTP's high specific impulse (> 850 second) enables a large range of destinations, shorter trip durations, and improved reliability. W-60vol%UO2 CERMET fuel development efforts emphasize fabrication, performance testing and process optimization to meet service life requirements. Fuel elements must be able to survive operation in excess of 2850 K, exposure to flowing hydrogen (H2), vibration, acoustic, and radiation conditions. CTE mismatch between W and UO2 result in high thermal stresses and lead to mechanical failure as a result UO2 reduction by hot hydrogen (H2) [1]. Improved powder metallurgy fabrication process control and mitigated fuel loss can be attained by coating UO2 starting powders within a layer of high density tungsten [2]. This paper discusses the advances of a fluidized bed chemical vapor deposition (CVD) system that utilizes the H2-WCl6 reduction process.

  16. Electroplating chromium on CVD SiC and SiCf-SiC advanced cladding via PyC compatibility coating

    NASA Astrophysics Data System (ADS)

    Ang, Caen; Kemery, Craig; Katoh, Yutai

    2018-05-01

    Electroplating Cr on SiC using a pyrolytic carbon (PyC) bond coat is demonstrated as an innovative concept for coating of advanced fuel cladding. The quantification of coating stress, SEM morphology, XRD phase analysis, and debonding test of the coating on CVD SiC and SiCf-SiC is shown. The residual tensile stress (by ASTM B975) of electroplated Cr is > 1 GPa prior to stress relaxation by microcracking. The stress can remove the PyC/Cr layer from SiC. Surface etching of ∼20 μm and roughening to Ra > 2 μm (by SEM observation) was necessary for successful adhesion. The debonding strength (by ASTM D4541) of the coating on SiC slightly improved from 3.6 ± 1.4 MPa to 5.9 ± 0.8 MPa after surface etching or machining. However, this improvement is limited due to the absence of an interphase, and integrated CVI processing may be required for further advancement.

  17. Measurement of the secondary electron emission from CVD diamond films using phosphor screen detectors

    NASA Astrophysics Data System (ADS)

    Vaz, R.; May, P. W.; Fox, N. A.; Harwood, C. J.; Chatterjee, V.; Smith, J. A.; Horsfield, C. J.; Lapington, J. S.; Osbourne, S.

    2015-03-01

    Diamond-based photomultipliers have the potential to provide a significant improvement over existing devices due to diamond's high secondary electron yield and narrow energy distribution of secondary electrons which improves energy resolution creating extremely fast response times. In this paper we describe an experimental apparatus designed to study secondary electron emission from diamond membranes only 400 nm thick, observed in reflection and transmission configurations. The setup consists of a system of calibrated P22 green phosphor screens acting as radiation converters which are used in combination with photomultiplier tubes to acquire secondary emission yield data from the diamond samples. The superior signal voltage sampling of the phosphor screen setup compared with traditional Faraday Cup detection allows the variation in the secondary electron yield across the sample to be visualised, allowing spatial distributions to be obtained. Preliminary reflection and transmission yield data are presented as a function of primary electron energy for selected CVD diamond films and membranes. Reflection data were also obtained from the same sample set using a Faraday Cup detector setup. In general, the curves for secondary electron yield versus primary energy for both measurement setups were comparable. On average a 15-20% lower signal was recorded on our setup compared to the Faraday Cup, which was attributed to the lower photoluminescent efficiency of the P22 phosphor screens when operated at sub-kilovolt bias voltages.

  18. A multifactorial analysis of obesity as CVD risk factor: use of neural network based methods in a nutrigenetics context.

    PubMed

    Valavanis, Ioannis K; Mougiakakou, Stavroula G; Grimaldi, Keith A; Nikita, Konstantina S

    2010-09-08

    Obesity is a multifactorial trait, which comprises an independent risk factor for cardiovascular disease (CVD). The aim of the current work is to study the complex etiology beneath obesity and identify genetic variations and/or factors related to nutrition that contribute to its variability. To this end, a set of more than 2300 white subjects who participated in a nutrigenetics study was used. For each subject a total of 63 factors describing genetic variants related to CVD (24 in total), gender, and nutrition (38 in total), e.g. average daily intake in calories and cholesterol, were measured. Each subject was categorized according to body mass index (BMI) as normal (BMI ≤ 25) or overweight (BMI > 25). Two artificial neural network (ANN) based methods were designed and used towards the analysis of the available data. These corresponded to i) a multi-layer feed-forward ANN combined with a parameter decreasing method (PDM-ANN), and ii) a multi-layer feed-forward ANN trained by a hybrid method (GA-ANN) which combines genetic algorithms and the popular back-propagation training algorithm. PDM-ANN and GA-ANN were comparatively assessed in terms of their ability to identify the most important factors among the initial 63 variables describing genetic variations, nutrition and gender, able to classify a subject into one of the BMI related classes: normal and overweight. The methods were designed and evaluated using appropriate training and testing sets provided by 3-fold Cross Validation (3-CV) resampling. Classification accuracy, sensitivity, specificity and area under receiver operating characteristics curve were utilized to evaluate the resulted predictive ANN models. The most parsimonious set of factors was obtained by the GA-ANN method and included gender, six genetic variations and 18 nutrition-related variables. The corresponding predictive model was characterized by a mean accuracy equal of 61.46% in the 3-CV testing sets. The ANN based methods revealed factors

  19. A multifactorial analysis of obesity as CVD risk factor: Use of neural network based methods in a nutrigenetics context

    PubMed Central

    2010-01-01

    Background Obesity is a multifactorial trait, which comprises an independent risk factor for cardiovascular disease (CVD). The aim of the current work is to study the complex etiology beneath obesity and identify genetic variations and/or factors related to nutrition that contribute to its variability. To this end, a set of more than 2300 white subjects who participated in a nutrigenetics study was used. For each subject a total of 63 factors describing genetic variants related to CVD (24 in total), gender, and nutrition (38 in total), e.g. average daily intake in calories and cholesterol, were measured. Each subject was categorized according to body mass index (BMI) as normal (BMI ≤ 25) or overweight (BMI > 25). Two artificial neural network (ANN) based methods were designed and used towards the analysis of the available data. These corresponded to i) a multi-layer feed-forward ANN combined with a parameter decreasing method (PDM-ANN), and ii) a multi-layer feed-forward ANN trained by a hybrid method (GA-ANN) which combines genetic algorithms and the popular back-propagation training algorithm. Results PDM-ANN and GA-ANN were comparatively assessed in terms of their ability to identify the most important factors among the initial 63 variables describing genetic variations, nutrition and gender, able to classify a subject into one of the BMI related classes: normal and overweight. The methods were designed and evaluated using appropriate training and testing sets provided by 3-fold Cross Validation (3-CV) resampling. Classification accuracy, sensitivity, specificity and area under receiver operating characteristics curve were utilized to evaluate the resulted predictive ANN models. The most parsimonious set of factors was obtained by the GA-ANN method and included gender, six genetic variations and 18 nutrition-related variables. The corresponding predictive model was characterized by a mean accuracy equal of 61.46% in the 3-CV testing sets. Conclusions The ANN

  20. Metal-Free CVD Graphene Synthesis on 200 mm Ge/Si(001) Substrates.

    PubMed

    Lukosius, M; Dabrowski, J; Kitzmann, J; Fursenko, O; Akhtar, F; Lisker, M; Lippert, G; Schulze, S; Yamamoto, Y; Schubert, M A; Krause, H M; Wolff, A; Mai, A; Schroeder, T; Lupina, G

    2016-12-14

    Good quality, complementary-metal-oxide-semiconductor (CMOS) technology compatible, 200 mm graphene was obtained on Ge(001)/Si(001) wafers in this work. Chemical vapor depositions were carried out at the deposition temperatures of 885 °C using CH 4 as carbon source on epitaxial Ge(100) layers, which were grown on Si(100), prior to the graphene synthesis. Graphene layer with the 2D/G ratio ∼3 and low D mode (i.e., low concentration of defects) was measured over the entire 200 mm wafer by Raman spectroscopy. A typical full-width-at-half-maximum value of 39 cm -1 was extracted for the 2D mode, further indicating that graphene of good structural quality was produced. The study also revealed that the lack of interfacial oxide correlates with superior properties of graphene. In order to evaluate electrical properties of graphene, its 2 × 2 cm 2 pieces were transferred onto SiO 2 /Si substrates from Ge/Si wafers. The extracted sheet resistance and mobility values of transferred graphene layers were ∼1500 ± 100 Ω/sq and μ ≈ 400 ± 20 cm 2 /V s, respectively. The transferred graphene was free of metallic contaminations or mechanical damage. On the basis of results of DFT calculations, we attribute the high structural quality of graphene grown by CVD on Ge to hydrogen-induced reduction of nucleation probability, explain the appearance of graphene-induced facets on Ge(001) as a kinetic effect caused by surface step pinning at linear graphene nuclei, and clarify the orientation of graphene domains on Ge(001) as resulting from good lattice matching between Ge(001) and graphene nucleated on such nuclei.

  1. Aluminum Coating Influence on Nitride Layer Performance Deposited by MO-CVD in Fluidized Bed on Austenitic Stainless Steel Substrate

    NASA Astrophysics Data System (ADS)

    Găluşcă, D. G.; Perju, M. C.; Nejneru, C.; Burduhos Nergiş, D. D.; Lăzărescu, I. E.

    2018-06-01

    The modification of surface properties by duplex treatments, involving the overlapping of two surface treatment techniques, has been established as an intelligent solution to create new applications for the substrate metallic material. There are driveline components operating under very tough wear and corrosion conditions, with high temperature and humidity variations. Such components are usually made of high Cr and Ni stainless steel and for the hardening of surfaces it is recommended a thermo chemical treatment. Since stainless steels, especially austenitic stainless steels, are difficult to nitride, experimental studies focus on increasing the depth of the nitride layer and surface hardness. Achieving the goal involves changing active layer chemical composition by introducing aluminum in the surface layer. In order to find a solution, a new surface treatment technique is produced by combining aluminum thin films by MO-CVD in a fluidized bed using a triisobutylaluminum precursor with a thermo chemical nitriding treatment.

  2. Growth of high quality AlN films on CVD diamond by RF reactive magnetron sputtering

    NASA Astrophysics Data System (ADS)

    Chen, Liang-xian; Liu, Hao; Liu, Sheng; Li, Cheng-ming; Wang, Yi-chao; An, Kang; Hua, Chen-yi; Liu, Jin-long; Wei, Jun-jun; Hei, Li-fu; Lv, Fan-xiu

    2018-02-01

    A highly oriented AlN layer has been successfully grown along the c-axis on a polycrystalline chemical vapor deposited (CVD) diamond by RF reactive magnetron sputtering. Structural, morphological and mechanical properties of the heterostructure were investigated by Scanning Electron Microscopy (SEM), Atomic Force Microscopy (AFM), Transmission Electron Microscopy (TEM), X-ray diffraction (XRD), Nano-indentation and Four-probe meter. A compact AlN film was demonstrated on the diamond layer, showing columnar grains and a low surface roughness of 1.4 nm. TEM results revealed a sharp AlN/diamond interface, which was characterized by the presence of a distinct 10 nm thick buffer layer resulting from the initial AlN growth stage. The FWHM of AlN (002) diffraction peak and its rocking curve are as low as 0.41° and 3.35° respectively, indicating a highly preferred orientation along the c-axis. AlN sputtered films deposited on glass substrates show a higher bulk resistivity (up to 3 × 1012 Ω cm), compared to AlN films deposited on diamond (∼1010 Ω cm). Finally, the film hardness and Young's modulus of AlN films on diamond are 25.8 GPa and 489.5 GPa, respectively.

  3. The community pharmacist's role in reducing CVD risk factors in Lebanon: a cross-sectional longitudinal study.

    PubMed

    Fahs, Iqbal; Hallit, Souheil; Rahal, Mohamad; Malaeb, Diana

    2018-06-13


    To assess the role of pharmacist in modifying CVDs risk factors among Lebanese adults in urban and rural areas.
    Materials (Subjects) and Methods
    In a prospective survey, 865 out of 1000 participants aged ≥ 45, previously interviewed, agreed to be followed at 1 and 2 year time points. Parameters including blood pressure, lipid profile, blood glucose, average number of risk factors, and atherosclerotic cardiovascular disease (ASCVD) risk were assessed and evaluated at the beginning of the study, then after 1 and 2 years.
    Results:
    After patient's education and during both follow ups, the mean average body mass index (BMI) and systolic blood pressure (SBP) statistically decreased significantly. The lipid profile as well statistically improved significantly during both follow-ups. to around 9%. Further statistically significant improvements in ASCVD risk occurred during the second follow-up to around 8%. Monitoring parameters revealed statistical significant improvements as well.
    Conclusion:
    This study showed that a plan that includes pharmacists, who regularly monitor and follow-up patients, could improve CVD prevention through reduction of risk factors.
    . ©2018The Author(s). Published by S. Karger AG, Basel.

  4. Writing in the Language Arts.

    ERIC Educational Resources Information Center

    Ediger, Marlow

    Pupils should participate in numerous forms and kinds of writing activities involving poetry and should hear, read, and write different forms and kinds of prose. Types of poetry that pupils can write include couplets, triplets, quatrains, limericks, free verse, haiku, and diamante. The ingredients that all types of poetry might have include…

  5. The Association between a Vegetarian Diet and Cardiovascular Disease (CVD) Risk Factors in India: The Indian Migration Study

    PubMed Central

    Shridhar, Krithiga; Dhillon, Preet Kaur; Bowen, Liza; Kinra, Sanjay; Bharathi, Ankalmadugu Venkatsubbareddy; Prabhakaran, Dorairaj; Reddy, Kolli Srinath; Ebrahim, Shah

    2014-01-01

    Background Studies in the West have shown lower cardiovascular disease (CVD) risk among people taking a vegetarian diet, but these findings may be confounded and only a minority selects these diets. We evaluated the association between vegetarian diets (chosen by 35%) and CVD risk factors across four regions of India. Methods Study participants included urban migrants, their rural siblings and urban residents, of the Indian Migration Study from Lucknow, Nagpur, Hyderabad and Bangalore (n = 6555, mean age-40.9 yrs). Information on diet (validated interviewer-administered semi-quantitative food frequency questionnaire), tobacco, alcohol, physical history, medical history, as well as blood pressure, fasting blood and anthropometric measurements were collected. Vegetarians ate no eggs, fish, poultry or meat. Using robust standard error multivariate linear regression models, we investigated the association of vegetarian diets with blood cholesterol, low density lipoprotein (LDL), high density lipoprotein (HDL), triglycerides, fasting blood glucose (FBG), systolic (SBP) and diastolic blood pressure (DBP). Results Vegetarians (32.8% of the study population) did not differ from non-vegetarians with respect to age, use of smokeless tobacco, body mass index, and prevalence of diabetes or hypertension. Vegetarians had a higher standard of living and were less likely to smoke, drink alcohol (p<0.0001) and were less physically active (p = 0.04). In multivariate analysis, vegetarians had lower levels of total cholesterol (β = −0.1 mmol/L (95% CI: −0.03 to −0.2), p = 0.006), triglycerides (β = −0.05 mmol/L (95% CI: −0.007 to −0.01), p = 0.02), LDL (β = −0.06 mmol/L (95% CI: −0.005 to −0.1), p = 0.03) and lower DBP (β = −0.7 mmHg (95% CI: −1.2 to −0.07), p = 0.02). Vegetarians also had decreases in SBP (β = −0.9 mmHg (95% CI: −1.9 to 0.08), p = 0.07) and FBG level (β = −0.07 mmol/L (95% CI:

  6. Effect of the energy of bombarding electrons on the conductivity of n-4H-SiC (CVD) epitaxial layers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kozlovski, V. V., E-mail: kozlovski@physics.spbstu.ru; Lebedev, A. A.; Strel’chuk, A. M.

    The electrical characteristics of epitaxial layers of n-4H-SiC (CVD) irradiated with 0.9 and 3.5MeV electrons are studied. It is shown that the donor removal rate becomes nearly four times higher as the energy of impinging electrons increases by a factor of 4, although the formation cross section of primary radiation defects (Frenkel pairs in the carbon sublattice) responsible for conductivity compensation of the material is almost energy independent in this range. It is assumed that the reason for the observed differences is the influence exerted by primary knocked-out atoms. First, cascade processes start to manifest themselves with increasing energy ofmore » primary knocked-out atoms. Second, the average distance between genetically related Frenkel pairs grows, and, as a consequence, the fraction of defects that do not recombine under irradiation becomes larger. The recombination radius of Frenkel pairs in the carbon sublattice is estimated and the possible charge state of the recombining components is assessed.« less

  7. The High performance of nanocrystalline CVD diamond coated hip joints in wear simulator test.

    PubMed

    Maru, M M; Amaral, M; Rodrigues, S P; Santos, R; Gouvea, C P; Archanjo, B S; Trommer, R M; Oliveira, F J; Silva, R F; Achete, C A

    2015-09-01

    The superior biotribological performance of nanocrystalline diamond (NCD) coatings grown by a chemical vapor deposition (CVD) method was already shown to demonstrate high wear resistance in ball on plate experiments under physiological liquid lubrication. However, tests with a close-to-real approach were missing and this constitutes the aim of the present work. Hip joint wear simulator tests were performed with cups and heads made of silicon nitride coated with NCD of ~10 μm in thickness. Five million testing cycles (Mc) were run, which represent nearly five years of hip joint implant activity in a patient. For the wear analysis, gravimetry, profilometry, scanning electron microscopy and Raman spectroscopy techniques were used. After 0.5 Mc of wear test, truncation of the protruded regions of the NCD film happened as a result of a fine-scale abrasive wear mechanism, evolving to extensive plateau regions and highly polished surface condition (Ra<10nm). Such surface modification took place without any catastrophic features as cracking, grain pullouts or delamination of the coatings. A steady state volumetric wear rate of 0.02 mm(3)/Mc, equivalent to a linear wear of 0.27 μm/Mc favorably compares with the best performance reported in the literature for the fourth generation alumina ceramic (0.05 mm(3)/Mc). Also, squeaking, quite common phenomenon in hard-on-hard systems, was absent in the present all-NCD system. Copyright © 2015 Elsevier Ltd. All rights reserved.

  8. Successful comeback of the single-dose live oral cholera vaccine CVD 103-HgR.

    PubMed

    Herzog, Christian

    2016-01-01

    Effective and easy to administer cholera vaccines are in need more than ever, for at risk populations and travellers alike. In many parts of the world cholera is still endemic, causing outbreaks and constituting repeatedly serious public health problems. The oral live cholera vaccine CVD 103-HgR (Orochol, Mutachol), the first genetically modified organism (GMO) used as vaccine, was in its time (launched 1993, Switzerland) the ideal cholera vaccine: single-dose, protective efficacy of 80-100% against moderate to severe cholera, acting within 8 days and exhibiting excellent safety, indiscernible from placebo. However, there were strong headwinds: In the 1990s the indication for cholera vaccines was generally downplayed by experts and in 1997 the European Commission called for a moratorium of GMOs which blocked the registration in the European Union. Thus, demand for this vaccine remained low and in 2003 it was taken off the market for economic reasons. After a decade in obscurity it (Vaxchora) has resurfaced again, now produced in the U.S. and equipped with a U.S. FDA license (June 10, 2016). What had happened? This commentary gives a critical account of an almost unbelievable string of misadventures, emerging adverse circumstances and man-made failures which nearly killed this single-dose live oral cholera vaccine. The good news is that patience and persistence lead to success in the end, allowing good science to prevail for the benefit of those in need. Copyright © 2016 Elsevier Ltd. All rights reserved.

  9. Dietary choline and betaine; associations with subclinical markers of cardiovascular disease risk and incidence of CVD, coronary heart disease and stroke: the Jackson Heart Study.

    PubMed

    Millard, Heather R; Musani, Solomon K; Dibaba, Daniel T; Talegawkar, Sameera A; Taylor, Herman A; Tucker, Katherine L; Bidulescu, Aurelian

    2018-02-01

    Several mechanisms have been described through which dietary intake of choline and its derivative betaine may be associated in both directions with subclinical atherosclerosis. We assessed the association of dietary intake of choline and betaine with cardiovascular risk and markers of subclinical cardiovascular disease. Data from 3924 Jackson Heart Study (JHS) African-American participants with complete food frequency questionnaire at baseline and follow-up measurements of heart disease measures were used. Multivariable linear regression models were employed to assess associations between choline and betaine intake with carotid intima-media thickness, coronary artery calcium, abdominal aortic calcium and left ventricular mass. Cox proportional hazards regression models were used to estimate associations with time to incident coronary heart disease (CHD), ischemic stroke and cardiovascular disease (CVD). During an average nine years of follow-up, 124 incident CHD events, 75 incident stroke events and 153 incident CVD events were documented. In women, greater choline intake was associated with lower left ventricular mass (p = 0.0006 for trend across choline quartiles) and with abdominal aortic calcium score. Among all JHS participants, there was a statistically significant inverse association between dietary choline intake and incident stroke, β = -0.33 (p = 0.04). Betaine intake was associated with greater risk of incident CHD when comparing the third quartile of intake with the lowest quartile of intake (HR 1.89, 95 % CI 1.14, 3.15). Among our African-American participants, higher dietary choline intake was associated with a lower risk of incident ischemic stroke, and thus putative dietary benefits. Higher dietary betaine intake was associated with a nonlinear higher risk of incident CHD.

  10. Highly photostable NV centre ensembles in CVD diamond produced by using N2O as the doping gas

    NASA Astrophysics Data System (ADS)

    Tallaire, A.; Mayer, L.; Brinza, O.; Pinault-Thaury, M. A.; Debuisschert, T.; Achard, J.

    2017-10-01

    High density Nitrogen-Vacancy (NV) centre ensembles incorporated in plasma assisted chemical vapour deposition (CVD) diamond are crucial to the development of more efficient sensing devices that use the properties of luminescent defects. Achieving high NV doping with N2 as the dopant gas source during diamond growth is, however, plagued by the formation of macroscopic and point defects that quench luminescence. Moreover, such NVs are found to exhibit poor photostability under high laser powers. Although this effect can be harnessed to locally and durably switch off NV luminescence for data storage, it is usually undesirable for most applications. In this work, the use of N2O as an alternative doping source is proposed. Much higher amounts of the doping gas can be added without significantly generating defects, which allows the incorporation of perfectly photostable and higher density NV ensembles. This effect is believed to be related to the lower dissociation energy of the N2O molecule together with the beneficial effect of the presence of a low and controlled amount of oxygen near the growing surface.

  11. Multilayered micro/nanocrystalline CVD diamond coatings for biotribology =

    NASA Astrophysics Data System (ADS)

    Salgueiredo, Ermelinda da Conceicao Portela

    In the present work multilayered micro/nanocrystalline (MCD/NCD) diamond coatings were developed by Hot Filament Chemical Vapour Deposition (HFCVD). The aim was to minimize the surface roughness with a top NCD layer, to maximize adhesion onto the Si3N4 ceramic substrates with a starting MCD coating and to improve the mechanical resistance by the presence of MCD/NCD interfaces in these composite coatings. This set of features assures high wear resistance and low friction coefficients which, combined to diamond biocompatibility, set this material as ideal for biotribological applications. The deposition parameters of MCD were optimized using the Taguchi method, and two varieties of NCD were used: NCD-1, grown in a methane rich gas phase, and NCD-2 where a third gas, Argon, was added to the gas mixture. The best combination of surface pre-treatments in the Si3N4 substrates is obtained by polishing the substrates with a 15 mum diamond slurry, further dry etching with CF4 plasma for 10 minutes and final ultrasonic seeding in a diamond powder suspension in ethanol for 1 hour. The interfaces of the multilayered CVD diamond films were characterized with high detail using HRTEM, STEM-EDX and EELS. The results show that at the transition from MCD to NCD a thin precursor graphitic film is formed. On the contrary, the transition of the NCD to MCD grade is free of carbon structures other than diamond, as a result of the richer atomic hydrogen content and of the higher substrate temperature for MCD deposition. At those transitions, WC nanoparticles were found due to contamination from the filament, being also present at the first interface of the MCD layer with the silicon nitride substrate. In order to study the adhesion and mechanical resistance of the diamond coatings, indentation and particle jet blasting tests were conducted, as well as tribological experiments with homologous pairs. Indentation tests proved the superior behaviour of the multilayered coatings that attained

  12. Epitaxial Growth of beta-Silicon Carbide (SiC) on a Compliant Substrate via Chemical Vapor Deposition (CVD)

    NASA Technical Reports Server (NTRS)

    Mitchell, Sharanda L.

    1996-01-01

    Many lattice defects have been attributed to the lattice mismatch and the difference in the thermal coefficient of expansion between SiC and silicon (Si). Stacking faults, twins and antiphase boundaries are some of the lattice defects found in these SiC films. These defects may be a partial cause of the disappointing performance reported for the prototype devices fabricated from beta-SiC films. The objective of this research is to relieve some of the thermal stress due to lattice mismatch when SiC is epitaxially grown on Si. The compliant substrate is a silicon membrane 2-4 microns thick. The CVD process includes the buffer layer which is grown at 1360 C followed by a very thin epitaxial growth of SiC. Then the temperature is raised to 1500 C for the subsequent growth of SiC. Since silicon melts at 1415 C, the SiC will be grown on molten Silicon which is absorbed by a porous graphite susceptor eliminating the SiC/Si interface. We suspect that this buffer layer will yield less stressed material to help in the epitaxial growth of SiC.

  13. Ambipolar transport in CVD grown MoSe2 monolayer using an ionic liquid gel gate dielectric

    NASA Astrophysics Data System (ADS)

    Ortiz, Deliris N.; Ramos, Idalia; Pinto, Nicholas J.; Zhao, Meng-Qiang; Kumar, Vinayak; Johnson, A. T. Charlie

    2018-03-01

    CVD grown MoSe2 monolayers were electrically characterized at room temperature in a field effect transistor (FET) configuration using an ionic liquid (IL) as the gate dielectric. During the growth, instead of using MoO3 powder, ammonium heptamolybdate was used for better Mo control of the source and sodium cholate added for lager MoSe2 growth areas. In addition, a high specific capacitance (˜7 μF/cm2) IL was used as the gate dielectric to significantly reduce the operating voltage. The device exhibited ambipolar charge transport at low voltages with enhanced parameters during n- and p-FET operation. IL gating thins the Schottky barrier at the metal/semiconductor interface permitting efficient charge injection into the channel and reduces the effects of contact resistance on device performance. The large specific capacitance of the IL was also responsible for a much higher induced charge density compared to the standard SiO2 dielectric. The device was successfully tested as an inverter with a gain of ˜2. Using a common metal for contacts simplifies fabrication of this ambipolar device, and the possibility of radiative recombination of holes and electrons could further extend its use in low power optoelectronic applications.

  14. Educational Service Quality in Zanjan University of Medical Sciences from Students' Point of View

    ERIC Educational Resources Information Center

    Mohammadi, Ali; Mohammadi, Jamshid

    2014-01-01

    This study aims at evaluating perceived service quality in Zanjan University of Medical Sciences (ZUMS). This study was cross-sectional and authors surveyed educational services at ZUMS. Through stratified random sampling, 384 students were selected and an adapted SERVQUAL instrument was used for data collection. Data analysis was performed by…

  15. Improving Post-Discharge Medication Adherence in Patients with CVD: A Pilot Randomized Trial

    PubMed Central

    Oliveira-Filho, Alfredo D.; Morisky, Donald E.; Costa, Francisco A.; Pacheco, Sara T.; Neves, Sabrina F.; Lyra-Jr, Divaldo P.

    2014-01-01

    Background Effective interventions to improve medication adherence are usually complex and expensive. Objective To assess the impact of a low-cost intervention designed to improve medication adherence and clinical outcomes in post-discharge patients with CVD. Method A pilot RCT was conducted at a teaching hospital. Intervention was based on the four-item Morisky Medication Adherence Scale (MMAS-4). The primary outcome measure was medication adherence assessed using the eight-item MMAS at baseline, at 1 month post hospital discharge and re-assessed 1 year after hospital discharge. Other outcomes included readmission and mortality rates. Results 61 patients were randomized to intervention (n = 30) and control (n = 31) groups. The mean age of the patients was 61 years (SD 12.73), 52.5% were males, and 57.4% were married or living with a partner. Mean number of prescribed medications per patient was 4.5 (SD 3.3). Medication adherence was correlated to intervention (p = 0.04) and after 1 month, 48.4% of patients in the control group and 83.3% in the intervention group were considered adherent. However, this difference decreased after 1 year, when adherence was 34.8% and 60.9%, respectively. Readmission and mortality rates were related to low adherence in both groups. Conclusion The intervention based on a validated patient self-report instrument for assessing adherence is a potentially effective method to improve adherent behavior and can be successfully used as a tool to guide adherence counseling in the clinical visit. However, a larger study is required to assess the real impact of intervention on these outcomes. PMID:25590930

  16. The Live Attenuated Cholera Vaccine CVD 103-HgR Primes Responses to the Toxin-Coregulated Pilus Antigen TcpA in Subjects Challenged with Wild-Type Vibrio cholerae.

    PubMed

    Mayo-Smith, Leslie M; Simon, Jakub K; Chen, Wilbur H; Haney, Douglas; Lock, Michael; Lyon, Caroline E; Calderwood, Stephen B; Kirkpatrick, Beth D; Cohen, Mitchell; Levine, Myron M; Gurwith, Marc; Harris, Jason B

    2017-01-01

    One potential advantage of live attenuated bacterial vaccines is the ability to stimulate responses to antigens which are only expressed during the course of infection. To determine whether the live attenuated cholera vaccine CVD 103-HgR (Vaxchora) results in antibody responses to the in vivo-induced toxin-coregulated pilus antigen TcpA, we measured IgA and IgG responses to Vibrio cholerae O1 El Tor TcpA in a subset of participants in a recently reported experimental challenge study. Participants were challenged with V. cholerae O1 El Tor Inaba N16961 either 10 days or 90 days after receiving the vaccine or a placebo. Neither vaccination nor experimental infection with V. cholerae alone resulted in a robust TcpA IgG or IgA response, but each did elicit a strong response to cholera toxin. However, compared to placebo recipients, vaccinees had a marked increase in IgG TcpA antibodies following the 90-day challenge, suggesting that vaccination with CVD 103-HgR resulted in priming for a subsequent response to TcpA. No such difference between vaccine and placebo recipients was observed for volunteers challenged 10 days after vaccination, indicating that this was insufficient time for vaccine-induced priming of the TcpA response. The priming of the response to TcpA and potentially other antigens expressed in vivo by attenuated V. cholerae may have relevance to the maintenance of immunity in areas where cholera is endemic. Copyright © 2017 American Society for Microbiology.

  17. Design and Development of an Acoustic Levitation System for Use in CVD Growth of Carbon Nanotubes

    NASA Astrophysics Data System (ADS)

    Qasem, Amal ali

    The most widely used methods for growth of carbon nanotubes (CNTs) arc discharge, laser ablation, and chemical vapor deposition (CVD). Some of these methods have difficulties, such as controlling the quality and straightness of the nanotube in the synthesis of CNTs from substrates. Also, the enhanced plasma chemical vapor deposition method with the catalyst on a substrate produces straighter, larger diameter nanotubes by the tip growth method, but they are short. The difficulty in the floating catalyst method is that the nanotubes stay in the growth furnace for short times limiting growth to about one mm length; this method also leaves many catalyst impurities. One factor that limits CNT growth in these methods is the difficulty of getting enough carbon atoms to the growth catalyst to grow long nanotubes. The motivation of this work is that longer, higher quality nanotubes could be grown by increasing growth time and by increasing carbon atom movement to catalyst. The goal of this project is to use acoustic levitation to assist chemical vapor deposition growth by trapping and vibrating the growing CNTs for better properties. Our levitation system consists of a piezoelectric transducer attached to an aluminum horn and quartz rod extending into the growth furnace. The most important elements of our methods to achieve the acoustic levitation are as follows. 1. Using COMSOL Multi-physic Simulation software to determine the length of quartz rod needed to excite standing waves for levitation in the tube furnace. 2. Determining the resonance frequency of different transducers and horns. 3. Using ultrasound measurement to determine the time of flight, velocity of sound and sound wavelength of different horns. 4. Making Aluminum horns with the appropriate lengths. 5. Using ultrasound measurement to determine the changing of quartz rod velocity of sound and length in the furnace. 6. Mounting the transducer to booster horn and aluminum cylindrical horn above a reflector to

  18. Endothelin type B (ETB) receptors: friend or foe in the pathogenesis of pre-eclampsia and future cardiovascular disease (CVD) risk?

    PubMed

    Mirabito Colafella, Katrina M

    2018-01-16

    In a recent issue of Clinical Science, Stanhewicz et al. investigated persistent microvascular dysfunction in women up to 16 months postpartum. The authors found sensitivity to the pressor effects of endothelin-1 (ET-1) was enhanced when compared with women who had a normotensive pregnancy. Importantly, the authors demonstrated that this effect was mediated via the endothelin type B (ET B ) receptors. Therefore, the present study highlights the possibility that alterations in the localization of the ET B receptor contributes to the pathogenesis of pre-eclampsia and future cardiovascular disease (CVD) risk. Currently, there is great interest in the role of the endothelin system in pre-eclampsia. Targetting the endothelin system, potentially by modulating upstream pathways to prevent ET B receptor dysfunction, may improve health outcomes for women and their offspring during pre-eclampsia and later life. © 2018 The Author(s). Published by Portland Press Limited on behalf of the Biochemical Society.

  19. Mapping of Low-Frequency Raman Modes in CVD-Grown Transition Metal Dichalcogenides: Layer Number, Stacking Orientation and Resonant Effects

    PubMed Central

    O’Brien, Maria; McEvoy, Niall; Hanlon, Damien; Hallam, Toby; Coleman, Jonathan N.; Duesberg, Georg S.

    2016-01-01

    Layered inorganic materials, such as the transition metal dichalcogenides (TMDs), have attracted much attention due to their exceptional electronic and optical properties. Reliable synthesis and characterization of these materials must be developed if these properties are to be exploited. Herein, we present low-frequency Raman analysis of MoS2, MoSe2, WSe2 and WS2 grown by chemical vapour deposition (CVD). Raman spectra are acquired over large areas allowing changes in the position and intensity of the shear and layer-breathing modes to be visualized in maps. This allows detailed characterization of mono- and few-layered TMDs which is complementary to well-established (high-frequency) Raman and photoluminescence spectroscopy. This study presents a major stepping stone in fundamental understanding of layered materials as mapping the low-frequency modes allows the quality, symmetry, stacking configuration and layer number of 2D materials to be probed over large areas. In addition, we report on anomalous resonance effects in the low-frequency region of the WS2 Raman spectrum. PMID:26766208

  20. High-speed deposition of titanium carbide coatings by laser-assisted metal–organic CVD

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gong, Yansheng; Tu, Rong, E-mail: turong@whut.edu.cn; Goto, Takashi

    2013-08-01

    Graphical abstract: - Highlights: • A semiconductor laser was first used to prepare wide-area LCVD-TiC{sub x} coatings. • The effect of laser power for the deposition of TiC{sub x} coatings was discussed. • TiC{sub x} coatings showed a columnar cross section and a dense surface texture. • TiC{sub x} coatings had a 1–4 order lower laser density than those of previous reports. • This study gives the possibility of LCVD applying on the preparation of TiC{sub x} coating. - Abstract: A semiconductor laser-assisted chemical vapor deposition (LCVD) of titanium carbide (TiC{sub x}) coatings on Al{sub 2}O{sub 3} substrate using tetrakismore » (diethylamido) titanium (TDEAT) and C{sub 2}H{sub 2} as source materials were investigated. The influences of laser power (P{sub L}) and pre-heating temperature (T{sub pre}) on the microstructure and deposition rate of TiC{sub x} coatings were examined. Single phase of TiC{sub x} coatings were obtained at P{sub L} = 100–200 W. TiC{sub x} coatings had a cauliflower-like surface and columnar cross section. TiC{sub x} coatings in the present study had the highest R{sub dep} (54 μm/h) at a relative low T{sub dep} than those of conventional CVD-TiC{sub x} coatings. The highest volume deposition rate (V{sub dep}) of TiC{sub x} coatings was about 4.7 × 10{sup −12} m{sup 3} s{sup −1}, which had 3–10{sup 5} times larger deposition area and 1–4 order lower laser density than those of previous LCVD using CO{sub 2}, Nd:YAG and argon ion laser.« less

  1. Initiated Chemical Vapor Deposition (iCVD) of Highly Cross-Linked Polymer Films for Advanced Lithium-Ion Battery Separators.

    PubMed

    Yoo, Youngmin; Kim, Byung Gon; Pak, Kwanyong; Han, Sung Jae; Song, Heon-Sik; Choi, Jang Wook; Im, Sung Gap

    2015-08-26

    We report an initiated chemical vapor deposition (iCVD) process to coat polyethylene (PE) separators in Li-ion batteries with a highly cross-linked, mechanically strong polymer, namely, polyhexavinyldisiloxane (pHVDS). The highly cross-linked but ultrathin pHVDS films can only be obtained by a vapor-phase process, because the pHVDS is insoluble in most solvents and thus infeasible with conventional solution-based methods. Moreover, even after the pHVDS coating, the initial porous structure of the separator is well preserved owing to the conformal vapor-phase deposition. The coating thickness is delicately controlled by deposition time to the level that the pore size decreases to below 7% compared to the original dimension. The pHVDS-coated PE shows substantially improved thermal stability and electrolyte wettability. After incubation at 140 °C for 30 min, the pHVDS-coated PE causes only a 12% areal shrinkage (versus 90% of the pristine separator). The superior wettability results in increased electrolyte uptake and ionic conductivity, leading to significantly improved rate performance. The current approach is applicable to a wide range of porous polymeric separators that suffer from thermal shrinkage and poor electrolyte wetting.

  2. Digitally enhanced recovery: Investigating the use of digital self-tracking for monitoring leisure time physical activity of cardiovascular disease (CVD) patients undergoing cardiac rehabilitation

    PubMed Central

    Auinger, Andreas; Riedl, René; Kindermann, Harald; Helfert, Markus; Ocenasek, Helmuth

    2017-01-01

    Research has shown that physical activity is essential in the prevention and treatment of chronic diseases like cardiovascular disease (CVD). Smart wearables (e.g., smartwatches) are increasingly used to foster and monitor human behaviour, including physical activity. However, despite this increased usage, little evidence is available on the effects of smart wearables in behaviour change. The little research which is available typically focuses on the behaviour of healthy individuals rather than patients. In this study, we investigate the effects of using smart wearables by patients undergoing cardiac rehabilitation. A field experiment involving 29 patients was designed and participants were either assigned to the study group (N = 13 patients who finished the study and used a self-tracking device) or the control group (N = 16 patients who finished the study and did not use a device). For both groups data about physiological performance during cardiac stress test was collected at the beginning (baseline), in the middle (in week 6, at the end of the rehabilitation in the organized rehabilitation setting), and at the end of the study (after 12 weeks, at the end of the rehabilitation, including the organized rehabilitation plus another 6 weeks of self-organized rehabilitation). Comparing the physiological performance of both groups, the data showed significant differences. The participants in the study group not only maintained the same performance level as during the midterm examination in week 6, they improved performance even further during the six weeks that followed. The results presented in this paper provide evidence for positive effects of digital self-tracking by patients undergoing cardiac rehabilitation on performance of the cardiovascular system. In this way, our study provides novel insight about the effects of the use of smart wearables by CVD patients. Our findings have implications for the design of self-management approaches in a patient rehabilitation

  3. Independent gate control of injected and detected spin currents in CVD graphene nonlocal spin valves

    NASA Astrophysics Data System (ADS)

    Anugrah, Yoska; Hu, Jiaxi; Stecklein, Gordon; Crowell, Paul A.; Koester, Steven J.

    2018-01-01

    Graphene is an ideal material for spintronic devices due to its low spin-orbit coupling and high mobility. One of the most important potential applications of graphene spintronics is for use in neuromorphic computing systems, where the tunable spin resistance of graphene can be used to apply analog weighting factors. A key capability needed to achieve spin-based neuromorphic computing systems is to achieve distinct regions of control, where injected and detected spin currents can be tuned independently. Here, we demonstrate the ability to achieve such independent control using a graphene spin valve geometry where the injector and detector regions are modulated by two separate bottom gate electrodes. The spin transport parameters and their dependence on each gate voltage are extracted from Hanle precession measurements. From this analysis, local spin transport parameters and their dependence on the local gate voltage are found, which provide a basis for a spatially-resolved spin resistance network that simulates the device. The data and model are used to calculate the spin currents flowing into, through, and out of the graphene channel. We show that the spin current flowing through the graphene channel can be modulated by 30% using one gate and that the spin current absorbed by the detector can be modulated by 50% using the other gate. This result demonstrates that spin currents can be controlled by locally tuning the spin resistance of graphene. The integration of chemical vapor deposition (CVD) grown graphene with local gates allows for the implementation of large-scale integrated spin-based circuits.

  4. Effects of Fiber Content on Mechanical Properties of CVD SiC Fiber-Reinforced Strontium Aluminosilicate Glass-Ceramic Composites

    NASA Technical Reports Server (NTRS)

    Bansal, Narottam P.

    1996-01-01

    Unidirectional CVD SiC(f)(SCS-6) fiber-reinforced strontium aluminosilicate (SAS) glass-ceramic matrix composites containing various volume fractions, approximately 16 to 40 volume %, of fibers were fabricated by hot pressing at 1400 C for 2 h under 27.6 MPa. Monoclinic celsian, SrAl2Si2O8, was the only crystalline phase formed, with complete absence of the undesired hexacelsian phase, in the matrix. Room temperature mechanical properties were measured in 3-point flexure. The matrix microcracking stress and the ultimate strength increased with increase in fiber volume fraction, reached maximum values for V(sub f) approximately equal to 0.35, and degraded at higher fiber loadings. This degradation in mechanical properties is related to the change in failure mode, from tensile at lower V(sub f) to interlaminar shear at higher fiber contents. The extent of fiber loading did not have noticeable effect on either fiber-matrix debonding stress, or frictional sliding stress at the interface. The applicability of micromechanical models in predicting the mechanical properties of the composites was also examined. The currently available theoretical models do not appear to be useful in predicting the values of the first matrix cracking stress, and the ultimate strength of the SCS-6/SAS composites.

  5. Synthesis of Multi-Walled Carbon Nanotubes from Plastic Waste Using a Stainless-Steel CVD Reactor as Catalyst.

    PubMed

    Tripathi, Pranav K; Durbach, Shane; Coville, Neil J

    2017-09-22

    The disposal of non-biodegradable plastic waste without further upgrading/downgrading is not environmentally acceptable and many methods to overcome the problem have been proposed. Herein we indicate a simple method to make high-value nanomaterials from plastic waste as a partial solution to the environmental problem. Laboratory-based waste centrifuge tubes made of polypropylene were chosen as a carbon source to show the process principle. In the process, multi-walled carbon nanotubes (MWCNTs) were synthesized from plastic waste in a two-stage stainless steel 316 (SS 316) metal tube that acted as both reactor vessel and catalyst. The steel reactor contains Fe (and Ni, and various alloys), which act as the catalyst for the carbon conversion process. The reaction and products were studied using electron probe microanalysis, thermogravimetric analysis, Raman spectroscopy and transmission electron microscopy and scanning electron microscopy. Optimization studies to determine the effect of different parameters on the process showed that the highest yield and most graphitized MWCNTs were formed at 900 °C under the reaction conditions used (yield 42%; Raman I D / I G ratio = 0.48). The high quality and high yield of the MWCNTs that were produced in a flow reactor from plastic waste using a two stage SS 316 chemical vapor deposition (CVD) furnace did not require the use of an added catalyst.

  6. Synthesis of Multi-Walled Carbon Nanotubes from Plastic Waste Using a Stainless-Steel CVD Reactor as Catalyst

    PubMed Central

    Durbach, Shane

    2017-01-01

    The disposal of non-biodegradable plastic waste without further upgrading/downgrading is not environmentally acceptable and many methods to overcome the problem have been proposed. Herein we indicate a simple method to make high-value nanomaterials from plastic waste as a partial solution to the environmental problem. Laboratory-based waste centrifuge tubes made of polypropylene were chosen as a carbon source to show the process principle. In the process, multi-walled carbon nanotubes (MWCNTs) were synthesized from plastic waste in a two-stage stainless steel 316 (SS 316) metal tube that acted as both reactor vessel and catalyst. The steel reactor contains Fe (and Ni, and various alloys), which act as the catalyst for the carbon conversion process. The reaction and products were studied using electron probe microanalysis, thermogravimetric analysis, Raman spectroscopy and transmission electron microscopy and scanning electron microscopy. Optimization studies to determine the effect of different parameters on the process showed that the highest yield and most graphitized MWCNTs were formed at 900 °C under the reaction conditions used (yield 42%; Raman ID/IG ratio = 0.48). The high quality and high yield of the MWCNTs that were produced in a flow reactor from plastic waste using a two stage SS 316 chemical vapor deposition (CVD) furnace did not require the use of an added catalyst. PMID:28937596

  7. Drastically Enhanced High-Rate Performance of Carbon-Coated LiFePO4 Nanorods Using a Green Chemical Vapor Deposition (CVD) Method for Lithium Ion Battery: A Selective Carbon Coating Process.

    PubMed

    Tian, Ruiyuan; Liu, Haiqiang; Jiang, Yi; Chen, Jiankun; Tan, Xinghua; Liu, Guangyao; Zhang, Lina; Gu, Xiaohua; Guo, Yanjun; Wang, Hanfu; Sun, Lianfeng; Chu, Weiguo

    2015-06-03

    Application of LiFePO4 (LFP) to large current power supplies is greatly hindered by its poor electrical conductivity (10(-9) S cm(-1)) and sluggish Li+ transport. Carbon coating is considered to be necessary for improving its interparticle electronic conductivity and thus electrochemical performance. Here, we proposed a novel, green, low cost and controllable CVD approach using solid glucose as carbon source which can be extended to most cathode and anode materials in need of carbon coating. Hydrothermally synthesized LFP nanorods with optimized thickness of carbon coated by this recipe are shown to have superb high-rate performance, high energy, and power densities, as well as long high-rate cycle lifetime. For 200 C (18s) charge and discharge, the discharge capacity and voltage are 89.69 mAh g(-1) and 3.030 V, respectively, and the energy and power densities are 271.80 Wh kg(-1) and 54.36 kW kg(-1), respectively. The capacity retention of 93.0%, and the energy and power density retention of 93.6% after 500 cycles at 100 C were achieved. Compared to the conventional carbon coating through direct mixing with glucose (or other organic substances) followed by annealing (DMGA), the carbon phase coated using this CVD recipe is of higher quality and better uniformity. Undoubtedly, this approach enhances significantly the electrochemical performance of high power LFP and thus broadens greatly the prospect of its applications to large current power supplies such as electric and hybrid electric vehicles.

  8. From Bench Top to Market: Growth of Multi-Walled Carbon Nanotubes by Injection CVD Using Fe Organometallics - Production of a Commercial Reactor

    NASA Technical Reports Server (NTRS)

    Rowsell, J.; Hepp, A. F.; Harris, J. D.; Raffaelle, R. P.; Cowen, J. C.; Scheiman, D. A.; Flood, D. M.; Flood, D. J.

    2009-01-01

    Preferential oriented multiwalled carbon nanotubes were prepared by the injection chemical vapor deposition (CVD) method using either cyclopentadienyliron dicarbonyl dimer or cyclooctatetraene iron tricarbonyl as the iron catalyst source. The catalyst precursors were dissolved in toluene as the carrier solvent for the injections. The concentration of the catalyst was found to influence both the growth (i.e., MWNT orientation) of the nanotubes, as well as the amount of iron in the deposited material. As deposited, the multiwalled carbon nanotubes contained as little as 2.8% iron by weight. The material was deposited onto tantalum foil and fused silica substrates. The nanotubes were characterized by scanning electron microscopy, transmission electron microscopy, Raman spectroscopy and thermogravimetric analysis. This synthetic route provides a simple and scalable method to deposit MWNTs with a low defect density, low metal content and a preferred orientation. Subsequently, a small start-up was founded to commercialize the deposition equipment. The contrast between the research and entrepreneurial environments will be discussed.

  9. Evaluating electrically insulating films deposited on V-4% Cr-4% Ti by reactive CVD

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Park, J.H.; Cho, W.D.

    1997-04-01

    Previous CaO coatings on V-4%Cr-4%Ti exhibited high-ohmic insulator behavior even though a small amount of vanadium from the alloy was incorporated in the coating. However, when the vanadium concentration in the coatings is > 15 wt%, the coating becomes conductive. When the vanadium concentration is high in localized areas, a calcium vanadate phase that exhibits semiconductor behavior can form. To explore this situation, CaO and Ca-V-O coatings were produced on vanadium alloys by chemical vapor deposition (CVD) and by a metallic-vapor process to investigate the electrical resistance of the coatings. Initially, the vanadium alloy specimens were either charged with oxygenmore » in argon that contained trace levels of oxygen, or oxidized for 1.5-3 h in a 1% CO-CO{sub 2} gas mixture or in air to form vanadium oxide at 625-650{degrees}C. Most of the specimens were exposed to calcium vapor at 800-850{degrees}C. Initial and final weights were obtained to monitor each step, and surveillance samples were removed for examination by optical and scanning electron microscopy and electron-energy-dispersive and X-ray diffraction analysis; the electrical resistivity was also measured. The authors found that Ca-V-O films exhibited insulator behavior when the ratio of calcium concentration to vanadium concentration R in the film was > 0.9, and semiconductor or conductor behavior for R < 0.8. However, in some cases, semiconductor behavior was observed when CaO-coated samples with R > 0.98 were exposed in liquid lithium. Based on these studies, the authors conclude that semiconductor behavior occurs if a conductive calcium vanadate phase is present in localized regions in the CaO coating.« less

  10. The Warfighter’s Stress Response: Telemetric and Noninvasive Assessment

    DTIC Science & Technology

    2002-09-01

    dorsal periaqueductal gray matter regulate anxiety in the social interaction test. Neuroreport. 9 (12): 1998; 2713-2716. 24. Nijsen MJ. Croiset G. Diamant...Psychobiological Model of Social Behavior. Developmental Psychobiology, 1996; 29 (8): 697-712. 31. Thayer, Julian F; Lane, Richard D.: A model of neurovisceral...of Psychology, College of Arts and Social Sciences, The University of West Florida. 42. Eichenbaum, H., & Otto, T. (1992). The hippocampus: What does

  11. Interlayer utilization (including metal borides) for subsequent deposition of NSD films via microwave plasma CVD on 316 and 440C stainless steels

    NASA Astrophysics Data System (ADS)

    Ballinger, Jared

    . Surface boriding was implemented using the novel method of microwave plasma CVD with a mixture of hydrogen and diborane gases. On 440C bearings, dual phase boride layers of Fe2B and FeB were formed which supported adhered nanostructured diamond films. Continuity of the films was not seamless with limited regions remaining uncoated potentially corresponding to delamination of the film as evidenced by the presence of tubular structures presumably composed of sp2 bonded carbon. Surface boriding of 316 stainless steel discs was conducted at various powers and pressures to achieve temperatures ranging from 550-800 °C. The substrate boriding temperature was found to substantially influence the resultant interlayer by altering the metal boride(s) present. The lowest temperatures produced an interlayer where CrB was the single detected phase, higher temperatures yielded the presence of only Fe2B, and a combination of the two phases resulted from an intermediate boriding temperature. Compared with the more common, commercialized boriding methods, this a profound result given the problems posed by the FeB phase in addition to other advantages offered by CVD processes and microwave generated plasmas in general. Indentation testing of the boride layers revealed excellent adhesion strength for all borided interlayers, and above all, no evidence of cracking was observed for a sole Fe2B phase. As with boriding of 440C bearings, subsequent diamond deposition was achieved on these interlayers with substantially improved adhesion strength relative to diamond coated TiN interlayers. Both XRD and Raman spectroscopy confirmed a nanostructured diamond film with interfacial chromium carbides responsible for enhanced adhesion strength. Interlayers consisting solely of Fe2B have displayed an ability to support fully continuous nanostructured diamond films, yet additional study is required for consistent reproduction. This is in good agreement with initial work on pack borided high alloy steels

  12. Formation pathway, structural characterization and optimum processing parameters of synthetic topaz – Al{sub 2}SiO{sub 4}(OH,F){sub 2} – by CVD

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Trujillo-Vázquez, E., E-mail: evatrujillo87@gmail.com; Pech-Canul, M.I., E-mail: martin.pech@cinvestav.edu.mx

    2015-10-15

    A novel synthesis route for topaz (Al{sub 2}SiO{sub 4}(OH,F){sub 2}) by chemical vapor deposition (CVD) using Na{sub 2}SiF{sub 6} as solid precursor was developed. Synthesis tests were conducted with and without a flow of nitrogen, positioning the Al(OH){sub 3} substrate at 0° and 90° with respect to the gas flow direction, at 700 and 750 °C, for 60 and 90 min, respectively. It was found that topaz is synthesized through two pathways, directly and indirectly, involving a series of endothermic and exothermic, heterogeneous and homogeneous reactions between Al(OH){sub 3} and SiF{sub 4}(g). Analytical structural determination confirmed existence of orthorhombic polycrystalsmore » with lattice parameters of a =4.6558 Å, b=8.8451 Å and c=8.4069 Å. According to ANOVA, while temperature, time and interaction of substrate angular position with atmosphere (P×A) are the parameters that most significantly influence the variability in the amount of topaz formed – equivalent contributions of 31% – topaz lattice parameters are mostly impacted by the same factors (T, t, P, A), but without the interaction factor. The projected amount of topaz is in good agreement with that obtained in confirmation tests under optimal conditions: Al(OH){sub 3} substrate compact placed at 0°, treated at 750 °C for 90 min in the absence of N{sub 2}. - Highlights: • Topaz synthesis as a unique phase by CVD, using solid precursor Na{sub 2}SiF{sub 6} is feasible. • Two pathways, a series of endothermic/exothermic, heterogeneous/homogeneous reactions. • Crystal structure, orthorhombic polycrystals: a =4.6558 Å, b=8.8451 Å, c=8.4069 Å. • Anova: amount of topaz formed and lattice parameters are impacted by same factors. • Projection of topaz quantity in good agreement with those from confirmation tests.« less

  13. Synthesis, characterization and oxidation of metallic cobalt (Co) thin film into semiconducting cobalt oxide (Co3O4)thin film using microwave plasma CVD

    NASA Astrophysics Data System (ADS)

    Rahman Ansari, Akhalakur; Hussain, Shahir; Imran, Mohd; Abdel-wahab, M. Sh; Alshahrie, Ahmed

    2018-06-01

    The pure cobalt thin film was deposited on the glass substrate by using DC magnetron sputtering and then exposed to microwave assist oxygen plasma generated in microwave plasma CVD. The oxidation process of Co thin film into Co3O4 thin films with different microwave power and temperature were studied. The influences of microwave power, temperature and irradiation time were investigated on the morphology and particle size of oxide thin films. The crystal structure, chemical conformation, morphologies and optical properties of oxidized Co thin films (Co3O4) were studied by using x-ray diffraction (XRD), Field emission scanning electron microscopy (FESEM), Raman Spectroscopy and UV–vis Spectroscopy. The data of these films showed complete oxidation pure metallic cobalt (Co) into cobalt oxide (Co3O4). The optical properties were studied for calculating the direct band gaps which ranges from 1.35 to 1.8 eV.

  14. Characterization of TEM Moiré Patterns Originating from Two Monolayer Graphenes Grown on the Front and Back Sides of a Copper Substrate by CVD Method

    NASA Astrophysics Data System (ADS)

    Yamazaki, Kenji; Maehara, Yosuke; Gohara, Kazutoshi

    2018-06-01

    The number of layers affects the electronic properties of graphene owing to its unique band structure, called the Dirac corn. Raman spectroscopy is a key diagnostic tool for identifying the number of graphene layers and for determining their physical properties. Here, we observed moiré structures in transmission electron microscopy (TEM) observations; these are signature patterns in multilayer, although Raman spectra showed the typical intensity of the 2D/G peak in the monolayer. We also performed a multi-slice TEM image simulation to compare the 3D atomic structures of the two graphene membranes with experimental TEM images. We found that the experimental moiré image was constructed with a 9-12 Å interlayer distance between graphene membranes. This structure was constructed by transferring CVD-grown graphene films that formed on both sides of the Cu substrate at once.

  15. Carbon fiber CVD coating by carbon nanostructured for space materials protection against atomic oxygen

    NASA Astrophysics Data System (ADS)

    Pastore, Roberto; Bueno Morles, Ramon; Micheli, Davide

    2016-07-01

    , by the purpose to integrate the carbon nanostructures in the carbon fibers by means of chemical vapor deposition (CVD) method, in order to develop the basic substrate of advanced carbon-based nanocomposite for atomic oxygen protection. The nanostructures grown onto the carbon fibers can be used to create multiscale hybrid carbon nanotube/carbon fiber composites where individual carbon fibers, which are several microns in diameter, are surrounded by nanotubes. The present objective is the setting-up of the CVD parameters for a reliable growth of carbon nanostructures on carbon fiber surface; after that, the results of a preliminary characterization related to atomic oxygen effects testing by means of a ground LEO simulation facility are reported and discussed.

  16. Von Donuts und Zucker: Mit Neutronen biologische Makromoleküle erforschen

    NASA Astrophysics Data System (ADS)

    May, Roland P.

    2003-05-01

    Für die Erforschung von Biomolekülen bieten Neutronen einzigartige Eigenschaften. Vor allem ihre unterschiedliche Wechselwirkung mit dem natürlichen Wasserstoff und seinem schweren Isotop Deuterium ermöglicht tiefe Einblicke in Struktur, Funktion und Dynamik von Proteinen, Nukleinsäuren und Biomembranen. Bei vielen Fragestellungen zur Strukturaufklärung gibt es kaum oder keine Alternative zum Neutron. Das Institut Laue-Langevin trägt Bahnbrechendes zum Erfolg der Neutronen-Methoden in der Biologie bei.

  17. Dissolution-and-reduction CVD synthesis of few-layer graphene on ultra-thin nickel film lifted off for mode-locking fiber lasers

    PubMed Central

    Peng, Kaung-Jay; Lin, Yung-Hsiang; Wu, Chung-Lun; Lin, Sheng-Fong; Yang, Chun-Yu; Lin, Shih-Meng; Tsai, Din-Ping; Lin, Gong-Ru

    2015-01-01

    The in-situ dissolution-and-reduction CVD synthesized few-layer graphene on ultra-thin nickel catalyst film is demonstrated at temperature as low as 550 °C, which can be employed to form transmission-type or reflection-type saturable absorber (SA) for mode-locking the erbium-doped fiber lasers (EDFLs). With transmission-type graphene SA, the EDFL shortens its pulsewidth from 483 to 441 fs and broadens its spectral linewidth from 4.2 to 6.1 nm with enlarging the pumping current from 200 to 900 mA. In contrast, the reflection-type SA only compresses the pulsewidth from 875 to 796 fs with corresponding spectral linewidth broadened from 2.2 to 3.3 nm. The reflection-type graphene mode-locker increases twice of its equivalent layer number to cause more insertion loss than the transmission-type one. Nevertheless, the reflection-type based saturable absorber system can generate stabilized soliton-like pulse easier than that of transmission-type system, because the nonlinearity induced self-amplitude modulation depth is simultaneously enlarged when passing through the graphene twice under the retro-reflector design. PMID:26328535

  18. Low-temperature formation of crystalline Si:H/Ge:H heterostructures by plasma-enhanced CVD in combination with Ni-nanodots seeding nucleation

    NASA Astrophysics Data System (ADS)

    Lu, Yimin; Makihara, Katsunori; Takeuchi, Daichi; Ikeda, Mitsuhisa; Ohta, Akio; Miyazaki, Seiichi

    2017-06-01

    Hydrogenated microcrystalline (µc) Si/Ge heterostructures were prepared on quartz substrates by plasma-enhanced chemical vapor deposition (CVD) from VHF inductively coupled plasma of SiH4 just after GeH4 employing Ni nanodots (NDs) as seeds for crystalline nucleation. The crystallinity of the films and the progress of grain growth were characterized by Raman scattering spectroscopy and atomic force microscopy (AFM), respectively. When the Ge films were grown on Ni-NDs at 250 °C, the growth of µc-Ge films with crystallinity as high as 80% was realized without an amorphous phase near the Ge film/quartz substrate interface. After the subsequent Si film deposition at 250 °C, fine grains were formed in the early stages of film growth on µc-Ge films with compositional mixing (µc-Si0.85Ge0.15:H) caused by the release of large lattice mismatch between c-Si and c-Ge. With further increase in Si:H film thickness, the formation of large grain structures accompanied by fine grains was promoted. These results suggest that crystalline Si/Ge heterojunctions can be used for efficient carrier collection in solar cell application.

  19. Low temperature plasma enhanced CVD epitaxial growth of silicon on GaAs: a new paradigm for III-V/Si integration

    NASA Astrophysics Data System (ADS)

    Cariou, Romain; Chen, Wanghua; Maurice, Jean-Luc; Yu, Jingwen; Patriarche, Gilles; Mauguin, Olivia; Largeau, Ludovic; Decobert, Jean; Roca I Cabarrocas, Pere

    2016-05-01

    The integration of III-V semiconductors with silicon is a key issue for photonics, microelectronics and photovoltaics. With the standard approach, namely the epitaxial growth of III-V on silicon, thick and complex buffer layers are required to limit the crystalline defects caused by the interface polarity issues, the thermal expansion, and lattice mismatches. To overcome these problems, we have developed a reverse and innovative approach to combine III-V and silicon: the straightforward epitaxial growth of silicon on GaAs at low temperature by plasma enhanced CVD (PECVD). Indeed we show that both GaAs surface cleaning by SiF4 plasma and subsequent epitaxial growth from SiH4/H2 precursors can be achieved at 175 °C. The GaAs native oxide etching is monitored with in-situ spectroscopic ellipsometry and Raman spectroscopy is used to assess the epitaxial silicon quality. We found that SiH4 dilution in hydrogen during deposition controls the layer structure: the epitaxial growth happens for deposition conditions at the transition between the microcrystalline and amorphous growth regimes. SIMS and STEM-HAADF bring evidences for the interface chemical sharpness. Together, TEM and XRD analysis demonstrate that PECVD enables the growth of high quality relaxed single crystal silicon on GaAs.

  20. Surface passivation of InGaP/GaAs HBT using silicon-nitride film deposited by ECR CVD plasma

    NASA Astrophysics Data System (ADS)

    Manera, L. T.; Zoccal, L. B.; Diniz, J. A.; Tatsch, P. J.; Doi, I.

    2008-07-01

    In this paper we have developed a passivation technique with silicon-nitride (SiN X) film that requires no surface pre-treatment, and is fully compatible to monolithic microwave integrated circuits (MMICs). The nitride depositions were carried out by ECR-CVD (electron cyclotron resonance-chemical vapor deposition) directly over InGaP/GaAs heterojunction structures, which are used for heterojunction bipolar transistors (HBTs). Optical emission spectrometry (OES) was used for plasma characterization, and low formation of H and NH molecules in the gas phase was detected at pressure of 2.5 mTorr. These molecules can degrade III-V semiconductor surfaces due to the preferential loss of As or P and hydrogen incorporation at the substrate. The substrates were cleaned with organic solvents using a Sox-let distillate. The ECR depositions were carried out at a fixed substrate temperature of 20 °C, SiH 4/N 2 flow ratio of 1, Ar flow of 5 sccm pressure of 2.5 mTorr and microwave (2.45 GHz) power of 250 W and RF (13.56 MHz) power of 4 W. We have applied this film for InGaP/GaAs HBT fabrication process with excellent results, where two major contribuiton is related to this passivation technique, the enhancement in the transistor dc gain β and the improvement in the signal-to-noise ratio when compared unpassivated and passivated devices.

  1. Synthesis of ACNT on quartz substrate with catalytic decomposition reaction from Cinnamomum camphora by using FC-CVD method

    NASA Astrophysics Data System (ADS)

    Wulan, Praswasti P. D. K.; Silaen, Toni Partogi Johannes

    2017-05-01

    Camphor is a renewable carbon source that can be used as raw material for synthesizing Carbon Nanotube (CNT). Camphor is a substance that can be found on the Cinnamomum camphora tree. In this research, the method used to synthesize Aligned Carbon Nanotube (ACNT) from camphor is Floating Catalyst Chemical Vapor Deposition (FC-CVD) with Ferrocene as catalyst at temperature of 800°C, hydrogen gas as the co-reactant and argon gas as carrier gas. This method is the most popular method of synthesizing ACNT which oriented and have a high density. Camphor decomposes into benzene, toluene, and xylene at a temperature of 800°C. By using GC-FID for characterization test, the results showed decomposition at a temperature of 800°C camphor dominated by benzene with a concentration of 92.422 to 97.656%. The research was conducted by varying the flow rate of carrier gas such as argon at 40, 55, 70, 85 and 100 mL / min at a temperature of 800°C for 60 minutes of reaction time. Argon carrier gas flow rate of 70 mL / min producing CNT with the highest yield, but this is not followed by best quality of CNT. CNT with best quality is obtained at a flow rate of argon carrier gas at 55 mL / min based on test results characterization by using SEM, EDX, Mapping, and RAMAN Spectroscopy. This research have not obtained CNT with aligned structured.

  2. CVD synthesis of large-area, highly crystalline MoSe2 atomic layers on diverse substrates and application to photodetectors.

    PubMed

    Xia, Jing; Huang, Xing; Liu, Ling-Zhi; Wang, Meng; Wang, Lei; Huang, Ben; Zhu, Dan-Dan; Li, Jun-Jie; Gu, Chang-Zhi; Meng, Xiang-Min

    2014-08-07

    Synthesis of large-area, atomically thin transition metal dichalcogenides (TMDs) on diverse substrates is of central importance for the large-scale fabrication of flexible devices and heterojunction-based devices. In this work, we successfully synthesized a large area of highly-crystalline MoSe2 atomic layers on SiO2/Si, mica and Si substrates using a simple chemical vapour deposition (CVD) method at atmospheric pressure. Atomic force microscopy (AFM) and Raman spectroscopy reveal that the as-grown ultrathin MoSe2 layers change from a single layer to a few layers. Photoluminescence (PL) spectroscopy demonstrates that while the multi-layer MoSe2 shows weak emission peaks, the monolayer has a much stronger emission peak at ∼ 1.56 eV, indicating the transition from an indirect to a direct bandgap. Transmission electron microscopy (TEM) analysis confirms the single-crystallinity of MoSe2 layers with a hexagonal structure. In addition, the photoresponse performance of photodetectors based on MoSe2 monolayer was studied for the first time. The devices exhibit a rapid response of ∼ 60 ms and a good photoresponsivity of ∼ 13 mA/W (using a 532 nm laser at an intensity of 1 mW mm(-2) and a bias of 10 V), suggesting that MoSe2 monolayer is a promising material for photodetection applications.

  3. An analysis of the specificity of defects embedded into (1 0 0) and (1 1 1) faceted CVD diamond microcrystals grown on Si and Mo substrates by using E/H field discharge

    NASA Astrophysics Data System (ADS)

    Nasieka, Iurii; Strelchuk, Victor; Naseka, Victor; Stubrov, Yuriy; Dudnik, Stanislav; Gritsina, Vasiliy; Opalev, Oleg; Koshevoy, Konstantin; Strel'nitskij, Vladimir; Tkach, Vasyl; Boyko, Mykola; Antypov, Ievgen

    2018-06-01

    The PE CVD method with magnetic field discharge stabilization was applied for the growth of arrays of freestanding diamond grains (island films) as well as continuous films on Mo and Si substrates with (1 1 1) and (1 0 0) faceted microcrystals, respectively. Raman, SEM, XRD and PL methods were used for search of the specific features of defects embedded into (1 0 0) and (1 1 1) faceted grains. The main characteristic differences in the defect states of the diamond island films grown on Si and Mo substrates with (1 0 0) and (1 1 1) faceted diamond microcrystals were discussed on the base of the experimental data.

  4. Temperature dependence of W metallic coatings synthesized by double glow plasma surface alloying technology on CVD diamond films

    NASA Astrophysics Data System (ADS)

    Gao, Jie; Hei, Hongjun; Shen, Yanyan; Liu, Xiaoping; Tang, Bin; He, Zhiyong; Yu, Shengwang

    2015-11-01

    W metallic coatings were synthesized on free-standing chemical vapor deposition (CVD) diamond films using double glow plasma surface alloying (DGPSA) technology. The influence of varying metalizing temperatures on the microstructures, phase composition and adhesion of the W metallic coatings were investigated. Likewise, the effectiveness of the W metallic coatings was preliminary evaluated via examining the shear strength of the brazing joints between W-metalized diamond films and commercial cemented carbide (WC-Co) inserts. The results showed that continuous and compact W metallic coatings were formed on the diamond films in the temperature range of 750-800 °C, while cracks or cavities presented at the W/diamond interface at 700 °C, 850 °C and 900 °C. Inter-diffusion of W and C atoms preformed, and WC and W2C were formed at the W/diamond interfaces at all temperatures except 700 °C, at which only W2C was formed. Moreover, etched cavities appeared at the W/diamond interface when the temperature exceeded 850 °C. The critical loads for coating delamination, as measured with the scratch test, increased as the temperature rose from 700 °C to 800 °C, while decreased with further increasing temperature. The maximum load was obtained at 800 °C with a value of 17.1 N. Besides, the shear strength of the brazing joints depicted the similar trend with the critical load. The highest shear strength (249 MPa) was also obtained at 800 °C.

  5. Enhancing quality of carbon nanotubes through a real-time controlled CVD process with application to next-generation nanosystems

    NASA Astrophysics Data System (ADS)

    Laxminarayana, Karthik; Jalili, Nader

    2004-07-01

    Nanocrystals and nanostructures will be the building blocks for future materials that will exhibit enhanced or entirely new combinations of properties with tremendous opportunity for novel technologies that can have far-reaching impact on our society. It is, however, realized that a major challenge for the near future is the design, synthesis and integration of nanostructures to develop functional nanosystems. In view of this, this exploratory research seeks to facilitate the development of a controlled and deterministic framework for nanomanufacturing of nanotubes as the most suitable choice among nanostructures for a plethora of potential applications in areas such as nanoelectronic devices, biological probes, fuel cell electrodes, supercapacitors and filed emission devices. Specifically, this paper proposes to control and maintain the most common nanotube growth parameters (i.e., reaction temperature and gas flow rate) through both software and hardware modifications. The influence of such growth parameters in a CVD process on some of the most vital and crucial aspects of nanotubes (e.g., length, diameter, yield, growth rate and structure) can be utilized to arrive at some unique and remarkable properties for the nanotubes. The objective here is, therefore, to control the process parameters to pinpoint accuracy, which would enable us to fabricate nanotubes having the desired properties and thereby maximize their ability to function at its fullest potential. To achieve this and in order to provide for experimental validation of the proposed research program, an experimental test-bed using the nanotube processing test chamber and a mechatronics workstation are being constructed.

  6. Innovative BI-Lösungen als Basis für eine erfolgreiche Transformation zu Utility 4.0

    NASA Astrophysics Data System (ADS)

    Phillipp, Daniel; Ebert, Sebastian

    Für eine erfolgreiche Transformation, vom reinen Energieversorger hin zum Energiedienstleister, werden innovative Business-Intelligence-Lösungen notwendig sein und eine zentrale Rolle einnehmen. Dabei ist es zunächst essenziell, die Herausforderungen zu kennen und ihnen mit geeigneten Analysen zu begegnen. Die Basis hierzu bildet eine abgestimmte und auf die strategischen Unternehmensziele ausgerichtete Architektur und Vorgehensweise. Zwei Beispiele veranschaulichen, wie ein gesamtheitlicher Ansatz, auch bei Datenvielfalt und hoher Komplexität, operative Prozesse optimiert, und fortgeschrittene Analysen zukünftig einen Beitrag zum Unternehmenserfolg liefern können.

  7. Geometrie verstehen: statisch - kinematisch

    NASA Astrophysics Data System (ADS)

    Kroll, Ekkehard

    Dem Allgemeinen steht begrifflich das Besondere gegenüber. In diesem Sinne sind allgemeine Überlegungen zum Verstehen von Mathematik zu ergänzen durch Untersuchungen hinsichtlich des Verstehens der einzelnen mathematischen Disziplinen, insbesondere der Geometrie. Hier haben viele Schülerinnen und Schüler Probleme. Diese rühren hauptsächlich daher, dass eine fertige geometrische Konstruktion in ihrer statischen Präsentation auf Papier nicht mehr die einzelnen Konstruktionsschritte erkennen lässt; zum Nachvollzug müssen sie daher ergänzend in einer Konstruktionsbeschreibung festgehalten werden.

  8. Chloride-based fast homoepitaxial growth of 4H-SiC films in a vertical hot-wall CVD

    NASA Astrophysics Data System (ADS)

    Guoguo, Yan; Feng, Zhang; Yingxi, Niu; Fei, Yang; Xingfang, Liu; Lei, Wang; Wanshun, Zhao; Guosheng, Sun; Yiping, Zeng

    2016-06-01

    Chloride-based fast homoepitaxial growth of 4H-SiC epilayers was performed on 4° off-axis 4H-SiC substrates in a home-made vertical hot-wall chemical vapor deposition (CVD) system using H2-SiH4-C2H4-HCl. The effect of the SiH4/H2 ratio and reactor pressure on the growth rate of 4H-SiC epilayers has been studied successively. The growth rate increase in proportion to the SiH4/H2 ratio and the influence mechanism of chlorine has been investigated. With the reactor pressure increasing from 40 to 100 Torr, the growth rate increased to 52 μm/hand then decreased to 47 μm/h, which is due to the joint effect of H2 and HCl etching as well as the formation of Si clusters at higher reactor pressure. The surface root mean square (RMS) roughness keeps around 1 nm with the growth rate increasing to 49 μm/h. The scanning electron microscope (SEM), Raman spectroscopy and X-ray diffraction (XRD) demonstrate that 96.7 μm thick 4H-SiC layers of good uniformity in thickness and doping with high crystal quality can be achieved. These results prove that chloride-based fast epitaxy is an advanced growth technique for 4H-SiC homoepitaxy. Project supported by the National High Technology R&D Program of China (No. 2014AA041402), the National Natural Science Foundation of China (Nos. 61474113, 61274007, 61574140), the Beijing Natural Science Foundation of China (Nos. 4132076, 4132074), the Program of State Grid Smart Grid Research Institute (No. SGRI-WD-71-14-004), and the Youth Innovation Promotion Association of CAS.

  9. Clinical investigation of vestibular damage by antituberculous drugs.

    PubMed

    Nakayama, M; Natori, Y; Tachi, H; Yoshizawa, M; Takayama, S; Miura, H; Kanayama, M; Kamei, T

    1986-01-01

    Vestibular function testing was done regularly on the cases given streptomycin, kanamycin, or enviomycin and a method to detect the cases of vestibular dysfunction at an early stage was discussed, as well as the time these drugs should be discontinued. Subjects were 85 cases of tuberculosis treated with streptomycin, kanamycin, or enviomycin who were admitted to our hospital from December 1984 to May 1986. The method of equilibrium examination performed at regular intervals is as follows: standing test (Romberg test), stepping test, and Meyer zum Gottesberge's head-shaking test were done once a week for a month after starting antituberculous injections and they were re-examined once every 2 weeks for at least 3 months after beginning the injections. After the 3 months these tests were done once a month. Eight cases of vestibular damage due to streptomycin or enviomycin could be easily detected at an early stage by performing Meyer zum Gottesberge's head-shaking test, together with the standing test and the stepping test. Vestibular dysfunction is apt to occur after about 1 month or within a month from the start of daily injections especially with streptomycin. Therefore, the method of equilibrium examination, we suggest, is that the Meyer zum Gottesberge's head-shaking test, the standing test (Romberg test), and the stepping test should be performed once a week during the first month after the start of this drug. When the result of the Meyer zum Gottesberge's head-shaking test is less than 50% and swaying and/or rotation occur in the stepping test, the drugs being given should be discontinued.

  10. Al-Mn CVD-FBR coating on P92 steel as protection against steam oxidation at 650 °C: TGA-MS study

    NASA Astrophysics Data System (ADS)

    Castañeda, S. I.; Pérez, F. J.

    2018-02-01

    The initial stages oxidation of the P92 ferritic/martensitic steel with and without Al-Mn coating at 650 °C in Ar+40%H2O for 240 h were investigated by mass spectrometry (MS) and thermogravimetric analysis (TGA). TGA-MS measurements were conducted in a closed steam loop. An Al-Mn coating was deposited on P92 steel at 580 °C for 2 h by chemical vapour deposition in a fluidized bed reactor (CVD-FBR). The coating as-deposited was treated in the same reactor at 700 °C in Ar for 2h, in order to produce aluminide phases that form the protective alumina layer (Al2O3) during oxidation. MS measurements at 650 °C of the Al-Mn/P92 sample for 200 h indicated the presence of (Al-Mn-Cr-Fe-O) volatile species of small intensity. Uncoated P92 steel oxidized under the same steam oxidation conditions emitted greater intensities of volatile species of Cr, Fe and Mo in comparison with intensities from coated steel. TGA measurements verified that the mass gained by the coated sample was up to 300 times lower than for uncoated P92 steel. The morphology, composition and structure of samples by Scanning Electron Microscopy SEM, Backscattered Electron (BSE) detection, X-ray Energy Dispersive Spectrometry (EDAX) and X-ray Diffraction (XRD) are described.

  11. Airbag-Systeme

    NASA Astrophysics Data System (ADS)

    Kramer, Florian

    Heutige Pkw sind zum Schutz der Insassen bei Frontalkollisionen zu etwa 90 % fahrerseitig und zu ca. 70 % auf der Beifahrerseite mit Airbags ausgestattet, während die Seiten-Airbags zum Schutz des Kopfes und des Thorax von Insassen bei Seitenkollisionen nur mit ungefähr 40 bis 50% vertreten sind [1]. Weitere Schutzmaßnahmen wie Fuß- und Fond-Airbags befinden sich im Entwicklungsstadium, ihr Einsatz in der Serie ist umstritten und wird sich, wenn überhaupt, nur in Einzelfällen durchsetzen. In Bild C3-1 sind Airbags dargestellt, die heute serienmäßig in Pkw anzutreffen sind.

  12. Probleme aus der Physik

    NASA Astrophysics Data System (ADS)

    Vogel, Helmut

    Das beliebte Arbeitsbuch "Probleme aus der Physik" bietet nun auch zur 17. Auflage von Gerthsen Vogel "Physik" (ISBN 3-540-56638-4) mit über 1150 gelösten Aufgaben aus der Physik und ihren Anwendungen in Technik, Astrophysik, Geound Biowissenschaften eine Fülle an Material zum Üben und Weiterlernen, zur Prüfungsvorbereitung und zum Selbststudium. Neu hinzugekommen ist ein Kapitel zur nichtlinearen Dynamik. Aufgaben aller Schwierigkeitsgrade machen "Probleme aus der Physik" unentbehrlich für Studenten der Physik im Haupt- und Nebenfach; Schüler der Leistungskurse Physik finden hier eine hervorragende Ergänzung.

  13. Evaluation of community health screening participants' knowledge of cardiovascular risk factors.

    PubMed

    Mooney, Leslie A; Franks, Amy M

    2009-01-01

    To assess knowledge of cardiovascular disease (CVD) risk factors among a group of health screening participants and to compare knowledge between participants with high and low CVD risk. Cross-sectional pilot study. Jonesboro, AR, during June 2007. 121 adult volunteers participating in a community health screening. 34-item self-administered written questionnaire. Ability to identify CVD risk factors and healthy values for CVD risk factors and the differences in these abilities between participants with high and low CVD risk. Participants demonstrated good knowledge of traditional CVD risk factors such as high blood pressure, high cholesterol, lack of exercise, and overweight or obese status. Knowledge of other CVD risk factors and healthy values for major CVD risk factors was limited. Participants with high CVD risk were significantly more likely to correctly identify high triglycerides as a CVD risk factor and to identify healthy values for fasting blood glucose and total cholesterol compared with participants with low CVD risk. Overall, participants lacked knowledge of the risk factor status and healthy values for many CVD risk factors. Participants with high CVD risk may have better knowledge of some CVD risk factors than participants with low CVD risk. These findings highlight the need for more education to improve knowledge in both risk groups.

  14. Characterisation Of Polysacharides And Lipids From Selected Green Algae Species By FTIR-ATR Spectroscopy

    NASA Astrophysics Data System (ADS)

    Bartošová, Alica; Blinová, Lenka; Gerulová, Kristína

    2015-06-01

    Fourier transform infrared (FTIR) spectroscopy was used in this study to identify and determine spectral features of Chromochloris zofingiensis (Dönz) Fucíková et L.A. Lewis (SAG 211-14, Gottingen, Germany), Acutodesmus obliguus (Turpin) Hegewald (SAG 276-1, Gottingen, Germany) and Chlorella sorokiniana (K. Brandt) Pröschold et Darienko (SAG 211-40c, Gottingen, Germany). Polysaccharides and lipids from these three algae species were determined using Fourier Transformed Infrared Spectroscopy (FTIR) with ATR accessory with diamante crystal in spectral range from 400 - 4000 cm-1 and resolution 4.

  15. Parental Age of Onset of Cardiovascular Disease as a Predictor for Offspring Age of Onset of Cardiovascular Disease.

    PubMed

    Allport, Shannon Anjelica; Kikah, Ngum; Abu Saif, Nessim; Ekokobe, Fonkem; Atem, Folefac D

    2016-01-01

    The risk for cardiovascular disease (CVD) is higher for individuals with a first-degree relative who developed premature CVD (with a threshold at age 55 years for a male or 65 years for a female). However, little is known about the effect that each unit increase or decrease of maternal or paternal age of onset of CVD has on offspring age of onset of CVD. We hypothesized that there is an association between maternal and paternal age of onset of CVD and offspring age of onset of CVD. We used the Framingham Heart Study database and performed conditional imputation for CVD-censored parental age (i.e. parents that didn't experience onset of CVD) and Cox proportional regression analysis, with offspring's age of onset of CVD as the dependent variable and parental age of onset of CVD as the primary predictor. Modifiable risk factors in offspring, such as cigarette smoking, body mass index (BMI), diabetes mellitus, systolic blood pressure (SBP), high-density lipoprotein (HDL) level, and low-density lipoprotein (LDL) level, were controlled for. Separate analyses were performed for the association between maternal age of onset of CVD and offspring age of onset of CVD and the association between paternal age of onset of CVD and offspring age of onset of CVD. Parental age of onset of CVD was predictive of offspring age of onset of CVD for maternal age of onset of CVD (P < .0001; N = 1401) and for paternal age of onset of CVD (P = 0.0134; N = 1221). A negative estimate of the coefficient of interest signifies that late onset of cardiovascular events in parents is protective of onset of CVD in offspring. Cigarette smoking and HDL level were important associated confounders. Offspring age of onset of cardiovascular disease is significantly associated with both maternal and paternal age of onset CVD. The incorporation of the parameters, maternal or paternal age of onset of CVD, into risk estimate calculators may improve accuracy of identification of high-risk patients in clinical

  16. Cardiovascular Disease Prevalence and Risk Factors of Persons with Mental Retardation

    ERIC Educational Resources Information Center

    Draheim, Christopher C.

    2006-01-01

    This paper reviews the recent literature on cardiovascular disease (CVD) prevalence, CVD-related mortality, physiological CVD risk factors, and behavioral CVD risk factors in adults with mental retardation (MR). The literature on the potential influences of modifiable behavioral CVD risk factors and the physiological CVD risk factors are also…

  17. Vom Urknall zum Durchknall

    NASA Astrophysics Data System (ADS)

    Unzicker, Alexander

    Lautstarker Applaus erhob sich im Salon III/IV des Marriott-Hotels von Crystal City im amerikanischen Bundesstaat Virginia. In dem überfüllten Konferenzraum starrten alle wie gebannt auf die Leinwand, wo nicht mehr zu sehen war als ein nüchternes Diagramm aus zahlreichen Punkten und einer geschwungenen Kurve. Nureine eigenartige Personengruppe konnte sich davon zu Emotionen hinreißen lassen - Physiker auf der Jahrestagung der Astronomischen Gesellschaft, die ihren Begeisterungssturm noch minutenlang fortsetzten. Was war geschehen? Die im Diagramm aufgetragenen Daten bestätigten mit einer nie da gewesenen Genauigkeit ein fundamentales Naturgesetz zur Wärmeabstrahlung von heißen Körpern. 1900 von Max Planck entdeckt, leuchtete es nun in geradezu mathematischer Reinheit auf. Noch sensationeller war der Ursprung der Daten - Mikrowellensignale verschiedener Frequenzen, die nicht aus einem irdischen Labor stammten, sondern von einem heißen Urzustand des Universums! Ein Feuerball aus Wasserstoff und Helium, noch ohne jegliche Strukturen, die irgendwann Leben ermöglichen sollten, ließ damals seinem Licht freien Lauf. Mehr als zehn Milliarden Jahre war es bis zu den Detektoren des vom Menschen gebauten Satelliten COBE unterwegs, der wenige Tage zuvor die Daten übertragen hatte. Wenn ich das alles wie einen Film in meiner Vorstellung ablaufen lasse, bekomme ich immer eine Gänsehaut, als würde ich die inzwischen extrem abgekühlte Strahlung tatsächlich spüren. Ihre Gleichverteilung im Raum macht uns auch deutlich, dass wir uns nicht einbilden dürfen, an einem besonderen Ort im Universum zu leben - intelligente Aliens könnten sich seitdem überall entwickelt haben! Sollten sie - was nicht wahrscheinlich ist - uns wirklich von Zeit zu Zeit über die Schulter schauen, dann hätten sie an jenem Nachmittag des 13. Januar 1990, als der Vortrag stattfand, bestimmt anerkennend mit ihrem großen Kopf genickt.

  18. Meilensteine in der Erforschung der kompakten Objekte

    NASA Astrophysics Data System (ADS)

    Camenzind, Max

    Kompakte Objekte besitzen zum einen eine sehr hohe Dichte, und zum anderen sind sie durch die Tatsache charakterisiert, dass keine nuklearen Reaktionen mehr in ihrem Inneren stattfinden können. Aus diesem Grund können sie im Unterschied zu gewöhnlichen Sternen der Gravitation nicht mehr mit dem Druck des thermischen Gases widerstehen. In den Weißen Zwergen bzw. Neutronensternen wird der Gravitation der Quantendruck eines Elektronengases bzw. einer Neutronenflüssigkeit entgegengesetzt. Ein solches Gas besteht aus Elektronen bzw. Neutronen, die auf ihr niedrigstes Energieniveau zusammengepresst wurden. Durch die daraus resultierende hohe Bewegungsenergie der Fermionen wird der sogenannte Quantendruck erzeugt.

  19. Vivir Con Un Corazón Saludable: a Community-Based Educational Program Aimed at Increasing Cardiovascular Health Knowledge in High-Risk Hispanic Women.

    PubMed

    Romero, Daniela C; Sauris, Aileen; Rodriguez, Fátima; Delgado, Daniela; Reddy, Ankita; Foody, JoAnne M

    2016-03-01

    Hispanic women suffer from high rates of cardiometabolic risk factors and an increasingly disproportionate burden of cardiovascular disease (CVD). Particularly, Hispanic women with limited English proficiency suffer from low levels of CVD knowledge associated with adverse CVD health outcomes. Thirty-two predominantly Spanish-speaking Hispanic women completed, Vivir Con un Corazón Saludable (VCUCS), a culturally tailored Spanish language-based 6-week intensive community program targeting CVD health knowledge through weekly interactive health sessions. A 30-question CVD knowledge questionnaire was used to assess mean changes in CVD knowledge at baseline and postintervention across five major knowledge domains including CVD epidemiology, dietary knowledge, medical information, risk factors, and heart attack symptoms. Completion of the program was associated with a statistically significant (p < 0.001) increase in total mean CVD knowledge scores from 39 % (mean 11.7/30.0) to 66 % (mean 19.8/30.0) postintervention consistent with a 68 % increase in overall mean CVD scores. There was a statistically significant (p < 0.001) increase in mean knowledge scores across all five CVD domains. A culturally tailored Spanish language-based health program is effective in increasing CVD awareness among high CVD risk Hispanic women with low English proficiency and low baseline CVD knowledge.

  20. Cross-cultural adaptation, content validation, and reliability of the Nigerian Composite Lifestyle CVD Risk Factors Questionnaire for adolescents among Yoruba rural adolescents in Nigeria.

    PubMed

    Odunaiya, Nse A; Louw, Quinette A; Grimmer, Karen

    2017-06-01

    Assessment of lifestyle risk factors must be culturally- and contextually relevant and available in local languages. This paper reports on a study which aimed to cross culturally adapt a composite lifestyle cardiovascular disease (CVD) risk factors questionnaire into an African language (Yoruba) and testing some of its psychometric properties such as content validity and test retest reliability in comparison to the original English version. This study utilized a cross sectional design. Translation of the English version of the questionnaire into Yoruba was undertaken using the guideline by Beaton et al. The translated instrument was presented to 21 rural adolescents to assess comprehensibility and clarity using a sample of convenience. A test retest reliability was conducted among 150 rural adolescents using a purposive sampling. Data was analyzed using intraclass correlation (ICC ) model 3, Cohen kappa statistics and prevalence rates. ICC ranged between 0.4-0.8. The Yoruba version was completed 15-20 minutes and was reported to be culturally appropriate and acceptable for rural Nigerian adolescents. The Yoruba translation of the Nigerian composite lifestyle risk factors questionnaire performs at least as well as the original English version in terms of content validity and reliability. It took a shorter time to complete therefore may be more relevant to rural adolescents.

  1. Geographic Variation in Morbidity and Mortality of Cerebrovascular Diseases in Korea during 2011-2015.

    PubMed

    Lee, Juyeon; Bahk, Jinwook; Kim, Ikhan; Kim, Yeon-Yong; Yun, Sung-Cheol; Kang, Hee-Yeon; Lee, Jeehye; Park, Jong Heon; Shin, Soon-Ae; Khang, Young-Ho

    2018-03-01

    Little is known about within-country variation in morbidity and mortality of cerebrovascular diseases (CVDs). Geographic differences in CVD morbidity and mortality have yet to be properly examined. This study examined geographic variation in morbidity and mortality of CVD, neighborhood factors for CVD morbidity and mortality, and the association between CVD morbidity and mortality across the 245 local districts in Korea during 2011-2015. District-level health care utilization and mortality data were obtained to estimate age-standardized CVD morbidity and mortality. The bivariate Pearson correlation was used to examine the linear relationship between district-level CVD morbidity and mortality Z-scores. Simple linear regression and multivariate analyses were conducted to investigate the associations of area characteristics with CVD morbidity, mortality, and discrepancies between morbidity and mortality. Substantial variation was found in CVD morbidity and mortality across the country, with 1074.9 excess CVD inpatients and 73.8 excess CVD deaths per 100,000 between the districts with the lowest and highest CVD morbidity and mortality, respectively. Higher rates of CVD admissions and deaths were clustered in the noncapital regions. A moderate geographic correlation between CVD morbidity and mortality was found (Pearson correlation coefficient = .62 for both genders). Neighborhood level indicators for socioeconomic disadvantages, undersupply of health care resources, and unhealthy behaviors were positively associated with CVD morbidity and mortality and the relative standing of CVD mortality vis-à-vis morbidity. Policy actions targeting life-course socioeconomic conditions, equitable distribution of health care resources, and behavioral risk factors may help reduce geographic differences in CVD morbidity and mortality in Korea. Copyright © 2018 National Stroke Association. Published by Elsevier Inc. All rights reserved.

  2. Work stress and cardiovascular disease: a life course perspective.

    PubMed

    Li, Jian; Loerbroks, Adrian; Bosma, Hans; Angerer, Peter

    2016-05-25

    Individuals in employment experience stress at work, and numerous epidemiological studies have documented its negative health effects, particularly on cardiovascular disease (CVD). Although evidence on the various interrelationships between work stress and CVD has been accumulated, those observations have not yet been conceptualized in terms of a life course perspective. Using the chain of risk model, we would like to propose a theoretical model incorporating six steps: (1) work stress increases the risk of incident CVD in healthy workers. (2) Among those whose work ability is not fully and permanently damaged, work stress acts as a determinant of the process of return to work after CVD onset. (3) CVD patients experience higher work stress after return to work. (4) Work stress increases the risk of recurrent CVD in workers with prior CVD. (5) CVD patients who fully lose their work ability transit to disability retirement. (6) Disability retirees due to CVD have an elevated risk of CVD mortality. The life course perspective might facilitate an in-depth understanding of the diverse interrelationships between work stress and CVD, thereby leading to work stress management interventions at each period of the lifespan and three-level prevention of CVD.

  3. Chronic Kidney Disease as a Predictor of Cardiovascular Disease (From the Framingham Heart Study)

    PubMed Central

    Parikh, Nisha I.; Hwang, Shih-Jen; Larson, Martin G.; Levy, Daniel; Fox, Caroline S.

    2008-01-01

    Chronic kidney disease (CKD) is a risk factor for cardiovascular disease (CVD), although shared risk factors may mediate much of the association. We related CKD and CVD in the setting of specific CVD risk factors and determined whether more advanced CKD was a CVD risk equivalent. The Framingham Heart Study original cohort (n=2471, mean age 68 years, 58.9% women) was studied. Glomerular filtration rate (eGFR) was estimated using the simplified Modification of Diet in Renal Disease Study equation. CKD was defined as eGFR < 59 mL/min per 1.73 m2 (women) and < 64 (men) and Stage 3b CKD defined as eGFR 30-44 (women) and 30-50 (men). Cox Proportional Hazard models adjusting for CVD risk factors were used to relate CKD to CVD. We tested for effect modification by CVD risk factors. Overall, 23.2% of the study sample had CKD (n=574; mean eGFR 50 mL/min per 1.73 m2) and 5.3% had Stage 3b CKD (n=131; mean eGFR 42 mL/min per 1.73 m2). In multivariable models (mean follow-up time 16 years), Stage 3 CKD was marginally associated with CVD (HR=1.17, 95% CI 0.99-1.38, p=0.06), whereas Stage 3b CKD was associated with CVD [HR=1.41, 95% CI 1.05-1.91, p=0.02]. Upon testing CVD risk equivalency, the risk of CVD for Stage 3b CKD among participants with prior CVD was significantly lower as compared to participants with prior CVD and no Stage 3b CKD (age- and sex-adjusted HR for CVD = 0.66 [95% CI 0.47 to 0.91], p=0.01). Low HDL modified the association between CKD and CVD (p-value=0.004 for interaction). Stage 3b CKD is associated with CVD but is not a CVD risk equivalent. In conclusion, CVD risk in the setting of CKD is higher in the setting of low HDL cholesterol. PMID:18572034

  4. Cardiovascular disease risk factors and the perception of general health among male law enforcement officers: encouraging behavioral change.

    PubMed

    Ramey, Sandra L

    2003-05-01

    The relationship among cardiovascular disease (CVD) morbidity, risk factors (including stress), and the perception of health among male law enforcement officers (LEOs) compared to men in the general population were examined in this study. Self reported prevalence of CVD and CVD risk factors among currently employed male LEOs from nine states (n = 2,818) were compared to those of other men in the same states (n = 9,650 for CVD risk factors, n = 3,147 for CVD prevalence). Perceived stress in LEOs was assessed to determine if it affected the relationship between CVD prevalence and CVD risk factors. Cross tabulated simple percentages showed CVD was less prevalent in the LEO group than among the general population. The best predictor variables for CVD were perceived stress, time in the profession, and hypertension. The LEO group had greater prevalence of hypercholesterolemia, overweight, and tobacco use than the general population. However, a greater percentage of LEOs perceived their health as "good to excellent" compared to men in the general population. Using multivariate analysis of variance (MANOVA) it was determined that perceived stress was associated with CVD in the LEO group and three CVD risk factors (i.e., cholesterol, hypertension, physical activity) were significantly affected by perceived stress. Among susceptible officers, stress may contribute to CVD development as well as potentiate several CVD risk factors. However, an apparent lack of association exists between perception of general health and CVD risk in LEOs.

  5. Factors associated with blue-collar workers' risk perception of cardiovascular disease.

    PubMed

    Hwang, Won Ju; Hong, Oisaeng; Kim, Mi Ja

    2012-12-01

    The purpose of this study was to investigate the contribution of actual cardiovascular disease (CVD) risk, as well as, individual, psychosocial, and work-related factors as predictors of CVD risk perception among Korean blue-collar workers. The participants were 238 Korean blue-collar workers who worked in small companies. Data were collected through a survey; anthropometric and blood pressure measures; and blood sampling for lipid levels. Blue-collar workers had high actual CVD risk and low CVD risk perception. The significant predictors of risk perception included perceived health status, alcohol consumption, knowledge of CVD risk, actual CVD risk, decision latitude, and shift work. The model explained 26% of the variance in CVD risk perception. The result suggests when occupational health nurses are giving routine health examination in small companies, they can enhance CVD risk perception in blue-collar workers by providing essential information about CVD risk factors and personal counseling on the individual worker's CVD risk status.

  6. Association between breast-feeding and anthropometry and CVD risk factor status in adolescence and young adulthood: the Young Hearts Project, Northern Ireland.

    PubMed

    Holmes, Valerie A; Cardwell, Chris; McKinley, Michelle C; Young, Ian S; Murray, Liam J; Boreham, Colin A; Woodside, Jayne V

    2010-06-01

    To examine the association between breast-feeding and blood pressure, anthropometry and plasma lipid profile in both adolescence and young adulthood. Longitudinal study of biological and behavioural risk factors for CVD. The Young Hearts Project, Northern Ireland. Schoolchildren aged 12 years and 15 years who participated in a cross-sectional study of lifestyle and health, and who were followed up as young adults aged 20-25 years. There was no significant difference in height, weight, BMI, skinfold thickness measurements, blood pressure or plasma lipid profile in adolescents who had been breast-fed compared with those who had not been breast-fed. However, by the time these adolescents had reached adulthood, those who had been breast-fed were significantly taller than those who had not been breast-fed (standing height, P = 0.013; leg length, P = 0.035). Specifically, the breast-fed group was on average taller by 1.7 cm (95 % CI 0.4, 3.0 cm) and had longer legs by 1.0 cm (95 % CI 0.1, 1.9 cm). There was no significant difference in other anthropometric measures, blood pressure or plasma lipid profile in adults who had been breast-fed compared with those who had not been breast-fed. Compared with those who had not been breast-fed, individuals who had been breast-fed were taller in adulthood. Given the known association of increased adult height with improved life expectancy, the results from the present study support a beneficial effect of breast-feeding.

  7. Diets high in resistant starch increase plasma levels of trimethylamine-N-oxide, a gut microbiome metabolite associated with CVD risk.

    PubMed

    Bergeron, Nathalie; Williams, Paul T; Lamendella, Regina; Faghihnia, Nastaran; Grube, Alyssa; Li, Xinmin; Wang, Zeneng; Knight, Rob; Jansson, Janet K; Hazen, Stanley L; Krauss, Ronald M

    2016-12-01

    Production of trimethylamine-N-oxide (TMAO), a biomarker of CVD risk, is dependent on intestinal microbiota, but little is known of dietary conditions promoting changes in gut microbial communities. Resistant starches (RS) alter the human microbiota. We sought to determine whether diets varying in RS and carbohydrate (CHO) content affect plasma TMAO levels. We also assessed postprandial glucose and insulin responses and plasma lipid changes to diets high and low in RS. In a cross-over trial, fifty-two men and women consumed a 2-week baseline diet (41 percentage of energy (%E) CHO, 40 % fat, 19 % protein), followed by 2-week high- and low-RS diets separated by 2-week washouts. RS diets were assigned at random within the context of higher (51-53 %E) v. lower CHO (39-40 %E) intake. Measurements were obtained in the fasting state and, for glucose and insulin, during a meal test matching the composition of the assigned diet. With lower CHO intake, plasma TMAO, carnitine, betaine and γ-butyrobetaine concentrations were higher after the high- v. low-RS diet (P<0·01 each). These metabolites were not differentially affected by high v. low RS when CHO intake was high. Although the high-RS meal reduced postprandial insulin and glucose responses when CHO intake was low (P<0·01 each), RS did not affect fasting lipids, lipoproteins, glucose or insulin irrespective of dietary CHO content. In conclusion, a lower-CHO diet high in RS was associated with higher plasma TMAO levels. These findings, together with the absence of change in fasting lipids, suggest that short-term high-RS diets do not improve markers of cardiometabolic health.

  8. Development and optimization of carvedilol orodispersible tablets: enhancement of pharmacokinetic parameters in rabbits

    PubMed Central

    Aljimaee, Yazeed HM; El-Helw, Abdel-Rahim M; Ahmed, Osama AA; El-Say, Khalid M

    2015-01-01

    Background Carvedilol (CVD) is used for the treatment of essential hypertension, heart failure, and systolic dysfunction after myocardial infarction. Due to its lower aqueous solubility and extensive first-pass metabolism, the absolute bioavailability of CVD does not exceed 30%. To overcome these drawbacks, the objective of this work was to improve the solubility and onset of action of CVD through complexation with hydroxypropyl-β-cyclodextrin and formulation of the prepared complex as orodispersible tablets (ODTs). Methods Compatibility among CVD and all tablet excipients using differential scanning calorimetry and Fourier transform infrared spectroscopy, complexation of CVD with different polymers, and determination of the solubility of CVD in the prepared complexes were first determined. A Box-Behnken design (BBD) was used to study the effect of tablet formulation variables on the characteristics of the prepared tablets and to optimize preparation conditions. According to BBD design, 15 formulations of CVD-ODTs were prepared by direct compression and then evaluated for their quality attributes. The relative pharmacokinetic parameters of the optimized CVD-ODTs were compared with those of the marketed CVD tablet. A single dose, equivalent to 2.5 mg/kg CVD, was administered orally to New Zealand white rabbits using a double-blind, randomized, crossover design. Results The solubility of CVD was improved from 7.32 to 22.92 mg/mL after complexation with hydroxypropyl-β-cyclodextrin at a molar ratio of 1:2 (CVD to cyclodextrin). The formulated CVD-ODTs showed satisfactory results concerning tablet hardness (5.35 kg/cm2), disintegration time (18 seconds), and maximum amount of CVD released (99.72%). The pharmacokinetic data for the optimized CVD-ODT showed a significant (P<0.05) increase in maximum plasma concentration from 363.667 to 496.4 ng/mL, and a shortening of the time taken to reach maximum plasma concentration to 2 hours in comparison with the marketed tablet

  9. Magnetoseed - Vasculäres Tissue Engineering

    NASA Astrophysics Data System (ADS)

    Perea Saavedra, Héctor; Methe, Heiko; Wintermantel, Erich

    Gegenwärtig sind kardiovaskuläre Erkrankungen, allen voran die Arteriosklerose koronarer und zerebraler Gefäße, Ursache für 38% aller Todesfälle in Nordamerika und häufigste Todesursache europäischer Männer < 65 Jahre und zweithäufigste Todesursache bei Frauen [4]. Es wird prognostiziert, dass innerhalb der nächsten 10-15 Jahre kardiovaskuläre Erkrankungen und deren Komplikationen weltweit die häufigste Todesursache stellen werden. Dies ist zum einen Folge der ansteigenden Prävalenz kardiovaskulärer Erkrankungen in Osteuropa und zunehmend auch in den Entwicklungsländern, zum anderen Folge der kontinuierlich ansteigenden Inzidenz von Übergewicht und Diabetes mellitus in den westlichen Ländern.

  10. Community cardiovascular disease risk from cross-sectional general practice clinical data: a spatial analysis.

    PubMed

    Bagheri, Nasser; Gilmour, Bridget; McRae, Ian; Konings, Paul; Dawda, Paresh; Del Fante, Peter; van Weel, Chris

    2015-02-26

    Cardiovascular disease (CVD) continues to be a leading cause of illness and death among adults worldwide. The objective of this study was to calculate a CVD risk score from general practice (GP) clinical records and assess spatial variations of CVD risk in communities. We used GP clinical data for 4,740 men and women aged 30 to 74 years with no history of CVD. A 10-year absolute CVD risk score was calculated based on the Framingham risk equation. The individual risk scores were aggregated within each Statistical Area Level One (SA1) to predict the level of CVD risk in that area. Finally, the pattern of CVD risk was visualized to highlight communities with high and low risk of CVD. The overall 10-year risk of CVD in our sample population was 14.6% (95% confidence interval [CI], 14.3%-14.9%). Of the 4,740 patients in our study, 26.7% were at high risk, 29.8% were at moderate risk, and 43.5% were at low risk for CVD over 10 years. The proportion of patients at high risk for CVD was significantly higher in the communities of low socioeconomic status. This study illustrates methods to further explore prevalence, location, and correlates of CVD to identify communities of high levels of unmet need for cardiovascular care and to enable geographic targeting of effective interventions for enhancing early and timely detection and management of CVD in those communities.

  11. En route to controlled catalytic CVD synthesis of densely packed and vertically aligned nitrogen-doped carbon nanotube arrays.

    PubMed

    Boncel, Slawomir; Pattinson, Sebastian W; Geiser, Valérie; Shaffer, Milo S P; Koziol, Krzysztof K K

    2014-01-01

    The catalytic chemical vapour deposition (c-CVD) technique was applied in the synthesis of vertically aligned arrays of nitrogen-doped carbon nanotubes (N-CNTs). A mixture of toluene (main carbon source), pyrazine (1,4-diazine, nitrogen source) and ferrocene (catalyst precursor) was used as the injection feedstock. To optimize conditions for growing the most dense and aligned N-CNT arrays, we investigated the influence of key parameters, i.e., growth temperature (660, 760 and 860 °C), composition of the feedstock and time of growth, on morphology and properties of N-CNTs. The presence of nitrogen species in the hot zone of the quartz reactor decreased the growth rate of N-CNTs down to about one twentieth compared to the growth rate of multi-wall CNTs (MWCNTs). As revealed by electron microscopy studies (SEM, TEM), the individual N-CNTs (half as thick as MWCNTs) grown under the optimal conditions were characterized by a superior straightness of the outer walls, which translated into a high alignment of dense nanotube arrays, i.e., 5 × 10(8) nanotubes per mm(2) (100 times more than for MWCNTs grown in the absence of nitrogen precursor). In turn, the internal crystallographic order of the N-CNTs was found to be of a 'bamboo'-like or 'membrane'-like (multi-compartmental structure) morphology. The nitrogen content in the nanotube products, which ranged from 0.0 to 3.0 wt %, was controlled through the concentration of pyrazine in the feedstock. Moreover, as revealed by Raman/FT-IR spectroscopy, the incorporation of nitrogen atoms into the nanotube walls was found to be proportional to the number of deviations from the sp(2)-hybridisation of graphene C-atoms. As studied by XRD, the temperature and the [pyrazine]/[ferrocene] ratio in the feedstock affected the composition of the catalyst particles, and hence changed the growth mechanism of individual N-CNTs into a 'mixed base-and-tip' (primarily of the base-type) type as compared to the purely 'base'-type for undoped

  12. EULAR task force recommendations on annual cardiovascular risk assessment for patients with rheumatoid arthritis: an audit of the success of implementation in a rheumatology outpatient clinic.

    PubMed

    Ikdahl, Eirik; Rollefstad, Silvia; Olsen, Inge C; Kvien, Tore K; Hansen, Inger Johanne Widding; Soldal, Dag Magnar; Haugeberg, Glenn; Semb, Anne Grete

    2015-01-01

    EULAR recommendations for cardiovascular disease (CVD) risk management include annual CVD risk assessments for patients with rheumatoid arthritis (RA). We evaluated the recording of CVD risk factors (CVD-RF) in a rheumatology outpatient clinic, where EULAR recommendations had been implemented. Further, we compared CVD-RF recordings between a regular rheumatology outpatient clinic (RegROC) and a structured arthritis clinic (AC). In 2012, 1142 RA patients visited the rheumatology outpatient clinic: 612 attended RegROC and 530 attended AC. We conducted a search in the patient journals to ascertain the rate of CVD-RF recording. The overall CVD-RF recording rate was 40.1% in the rheumatology outpatient clinic, reflecting a recording rate of 59.1% in the AC and 23.6% in the RegROC. The odds ratios for having CVD-RFs recorded for patients attending AC compared to RegROC were as follows: blood pressure: 12.4, lipids: 5.0-6.0, glucose: 9.1, HbA1c: 6.1, smoking: 1.4, and for having all the CVD-RFs needed to calculate the CVD risk by the systematic coronary risk evaluation (SCORE): 21.0. The CVD-RF recording rate was low in a rheumatology outpatient clinic. However, a systematic team-based model was superior compared to a RegROC. Further measures are warranted to improve CVD-RF recording in RA patients.

  13. Cardiovascular disease incidence in adolescent and young adult cancer survivors: a retrospective cohort study.

    PubMed

    Keegan, Theresa H M; Kushi, Lawrence H; Li, Qian; Brunson, Ann; Chawla, X; Chew, Helen K; Malogolowkin, Marcio; Wun, Ted

    2018-06-01

    Few population-based studies have focused on cardiovascular disease (CVD) risk in adolescent and young adult (AYA; 15-39 years) cancer survivors and none have considered whether CVD risk differs by sociodemographic factors. Analyses focused on 79,176 AYA patients diagnosed with 14 first primary cancers in 1996-2012 and surviving > 2 years after diagnosis with follow-up through 2014. Data were obtained from the California Cancer Registry and State hospital discharge data. CVD included coronary artery disease, heart failure, and stroke. The cumulative incidence of developing CVD accounted for the competing risk of death. Multivariable Cox proportional hazards regression evaluated factors associated with CVD and the impact of CVD on mortality. Overall, 2249 (2.8%) patients developed CVD. Survivors of central nervous system cancer (7.3%), acute lymphoid leukemia (6.9%), acute myeloid leukemia (6.8%), and non-Hodgkin lymphoma (4.1%) had the highest 10-year CVD incidence. In multivariable models, African-Americans (hazard ratio (HR) = 1.55, 95% confidence interval (CI) = 1.33-1.81; versus non-Hispanic Whites), those with public/no health insurance (HR = 1.78, 95% CI = 1.61-1.96; versus private) and those who resided in lower socioeconomic status neighborhoods had a higher CVD risk. These sociodemographic differences in CVD incidence were apparent across most cancer sites. The risk of death was increased by eightfold or higher among AYAs who developed CVD. While cancer therapies are known to increase the risk of CVD, this study additionally shows that CVD risk varies by sociodemographic factors. The identification and mitigation of CVD risk factors in these subgroups may improve long-term patient outcomes.

  14. Racial and Ethnic Disparities in Cardiovascular Disease: An Assessment of Obstetrician-Gynecologists' Knowledge, Attitudes, and Practice Patterns.

    PubMed

    Jones, Katherine M; Carter, Michele M; Schulkin, Jay

    2015-06-01

    African American and Hispanic women are disproportionately affected by cardiovascular disease (CVD) and its many risk factors. Obstetrician-gynecologists (OB/GYNs) play an integral role in well-woman care and have a unique opportunity to provide CVD counseling and screening to these at-risk and underserved groups. To assess whether OB/GYN race/ethnicity and OB/GYN practices with increasing minority patient populations predicted differences in OB/GYNs' knowledge, attitudes, and practice patterns relevant to racial/ethnic disparities in CVD. This study also sought to determine provider and patient-related barriers to CVD care. A questionnaire on CVD was mailed to 273 members of The American College of Obstetricians and Gynecologists in March-July 2013. African American and Hispanic OB/GYNs and OB/GYN practices with increasing minority patient populations were more knowledgeable of CVD disparities. These OB/GYNs reported greater concern for minority women's CVD risk relative to White OB/GYNs. Overall, OB/GYNs appear less knowledgeable and concerned with Hispanics' increased CVD risk relative to African Americans'. The most commonly reported provider and patient-related barriers to CVD care were time constraints, patient nonadherence to treatment recommendations, and inadequate training. It is likely that minority OB/GYNs and those with practices with increasing minority patient populations have greater exposure to women at risk for CVD. Dissemination of educational information regarding Hispanic women's CVD risk profile may improve OB/GYN knowledge, counseling, and screening. Increased training in CVD and multicultural competency during medical school and residency should help OB/GYNs overcome what they report as primary barriers to CVD care.

  15. Chronic Inflammatory Diseases and Atherosclerotic Cardiovascular Disease: Innocent Bystanders or Partners in Crime?

    PubMed

    Hansen, Peter Riis

    2018-01-01

    Inflammation plays a significant role in atherosclerosis and cardiovascular disease (CVD). Patients with chronic inflammatory diseases are at increased risk of CVD, but it is debated whether this association is causal or dependent on shared risk factors, other exposures, genes, and/or inflammatory pathways. The current review summarizes epidemiological, clinical, and experimental data supporting the role of shared inflammatory mechanisms between atherosclerotic CVD and rheumatoid arthritis, psoriasis, inflammatory bowel disease, and periodontitis, respectively, and provides insights to future prospects in this area of research. Awareness of the role of inflammation in CVD in patients with chronic inflammatory diseases and the potential for anti-inflammatory therapy, e.g., with tumor necrosis factor-α inhibitors, to also reduce atherosclerotic CVD has evolved into guideline- based recommendations. These include regular CVD risk assessment, aggressive treatment of traditional CVD risk factors, and recognition of reduced CVD as an added benefit of strict inflammatory disease control. At present, chronic inflammatory diseases would appear to qualify as partners in crime and not merely innocent bystanders to CVD. However, definite incremental contributions of inflammation versus effects of the complex interplay with other CVD risk factors may never be fully elucidated and for the foreseeable future, inflammation is posed to maintain its current position as both a marker and a maker of CVD, with clinical utility both for identification of patient at risk of CVD and as target for therapy to reduce CVD. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  16. Cardiovascular risk estimation by professionally active cardiovascular nurses: results from the Basel 2005 Nurses Cohort.

    PubMed

    Scholte op Reimer, Wilma J M; Moons, Philip; De Geest, Sabina; Fridlund, Bengt; Heikkilä, Johanna; Jaarsma, Tiny; Lenzen, Mattie; Martensson, Jan; Norekvål, Tone M; Smith, Karen; Stewart, Simon; Strömberg, Anna; Thompson, David R

    2006-12-01

    Nurses play a key role in the prevention of cardiovascular disease (CVD) and one would, therefore, expect them to have a heightened awareness of the need for systematic screening and their own CVD risk profile. The aim of this study was to examine personal awareness of CVD risk among a cohort of cardiovascular nurses attending a European conference. Of the 340 delegates attending the 5th annual Spring Meeting on Cardiovascular Nursing (Basel, Switzerland, 2005), 287 (83%) completed a self-report questionnaire to assess their own risk factors for CVD. Delegates were also asked to give an estimation of their absolute total risk of experiencing a fatal CVD event in the next 10 years. Level of agreement between self-reported CVD risk estimation and their actual risk according to the SCORE risk assessment system was compared by calculating weighted Kappa (kappa(w)). Overall, 109 responders (38%) self-reported having either pre-existing CVD (only 2%), one or more markedly raised CVD risk factors, a high total risk of fatal CVD (> or =5% in 10 years) or a strong family history of CVD. About half of this cohort (53%) did not know their own total cholesterol level. Less than half (45%) reported having a 10-year risk of fatal CVD of <1%, while 13% reported having a risk > or =5%. Based on the SCORE risk function, the estimated 10-year risk of a fatal CVD event was <1% for 96% of responders: only 2% had a > or =5% risk of such an event. Overall, less than half (46%) of this cohort's self-reported CVD risk corresponded with that calculated using the SCORE risk function (kappa(w)=0.27). Most cardiovascular nurses attending a European conference in 2005 poorly understood their own CVD risk profile, and the agreement between their self-reported 10-year risk of a fatal CVD and their CVD risk using SCORE was only fair. Given the specialist nature of this conference, our findings clearly demonstrate a need to improve overall nursing awareness of the role and importance of systematic

  17. Diets high in resistant starch increase plasma levels of trimethylamine-N-oxide, a gut microbiome metabolite associated with CVD risk

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bergeron, Nathalie; Williams, Paul T.; Lamendella, Regina

    Production of trimethylamine-N-oxide (TMAO), a biomarker of CVD risk, is dependent on intestinal microbiota, but little is known of dietary conditions promoting changes in gut microbial communities. Resistant starches (RS) alter the human microbiota. We sought to determine whether diets varying in RS and carbohydrate (CHO) content affect plasma TMAO levels. We also assessed postprandial glucose and insulin responses and plasma lipid changes to diets high and low in RS. In a cross-over trial, fifty-two men and women consumed a 2-week baseline diet (41 percentage of energy (%E) CHO, 40 % fat, 19 % protein), followed by 2-week high- andmore » low-RS diets separated by 2-week washouts. RS diets were assigned at random within the context of higher (51–53 %E)v. lower CHO (39–40 %E) intake. Measurements were obtained in the fasting state and, for glucose and insulin, during a meal test matching the composition of the assigned diet. With lower CHO intake, plasma TMAO, carnitine, betaine andγ-butyrobetaine concentrations were higher after the high-v. low-RS diet (P<0·01 each). These metabolites were not differentially affected by highv. low RS when CHO intake was high. Although the high-RS meal reduced postprandial insulin and glucose responses when CHO intake was low (P<0·01 each), RS did not affect fasting lipids, lipoproteins, glucose or insulin irrespective of dietary CHO content. In conclusion, a lower-CHO diet high in RS was associated with higher plasma TMAO levels. These findings, together with the absence of change in fasting lipids, suggest that short-term high-RS diets do not improve markers of cardiometabolic health.« less

  18. Impact of anti-rheumatic treatment on cardiovascular risk in Asian patients with rheumatoid arthritis.

    PubMed

    Cho, Soo-Kyung; Kim, Dam; Won, Soyoung; Lee, Jiyoung; Park, ByeongJu; Jang, Eun Jin; Bae, Sang-Cheol; Sung, Yoon-Kyoung

    2018-02-01

    To estimate the incidence of cardiovascular disease (CVD) in Asian patients with rheumatoid arthritis (RA) and to evaluate the impact of anti-rheumatic treatment on the development of CVD. A retrospective cohort of Asian patients with RA was established to identify the incidence rate (IR) of CVD in RA patients. The cohort was generated using the Korean National Healthcare claims database, which contained claims from Jan 2009 to Dec 2013. A total of 137,512 RA patients were identified; individuals with a history of CVD for 6 months or more before the index date were excluded. Nested case-control samples were drawn from the full study population with a case:control ratio of 1:4 (n = 7102 cases; n = 27,018 controls without CVD). A conditional multivariate regression model was used to evaluate the impact of anti-rheumatic treatment on the development of CVD in RA patients after matching for age, sex, RA index date, comorbidities, and drug use (e.g., antiplatelet agents and cholesterol-lowering agents). The IR for development of overall CVD in RA patients was 182.1 (95% CI: 178.4-185.9) per 10,000 person-years. In models adjusted for other CVD risk factors, disease-modifying anti-rheumatic drugs (DMARDs) (OR = 0.79) were protective against CVD, and biologic DMARDs were not significantly associated with CVD risk (OR = 0.85). Corticosteroids (OR = 1.26) and NSAIDs (nonselective NSAIDs: OR = 1.32, Cox-2 inhibitors: OR = 1.31) were risk factors for CVD in RA patients. The use of DMARDs is protective against CVD, while corticosteroids and NSAIDs increased the risk of CVD in RA patients. Copyright © 2018 Elsevier Inc. All rights reserved.

  19. Standard cardiovascular disease risk algorithms underestimate the risk of cardiovascular disease in schizophrenia: evidence from a national primary care database.

    PubMed

    McLean, Gary; Martin, Julie Langan; Martin, Daniel J; Guthrie, Bruce; Mercer, Stewart W; Smith, Daniel J

    2014-10-01

    Schizophrenia is associated with increased cardiovascular mortality. Although cardiovascular disease (CVD) risk prediction algorithms are widely in the general population, their utility for patients with schizophrenia is unknown. A primary care dataset was used to compare CVD risk scores (Joint British Societies (JBS) score), cardiovascular risk factors, rates of pre-existing CVD and age of first diagnosis of CVD for schizophrenia (n=1997) relative to population controls (n=215,165). Pre-existing rates of CVD and the recording of risk factors for those without CVD were higher in the schizophrenia cohort in the younger age groups, for both genders. Those with schizophrenia were more likely to have a first diagnosis of CVD at a younger age, with nearly half of men with schizophrenia plus CVD diagnosed under the age of 55 (schizophrenia men 46.1% vs. control men 34.8%, p<0.001; schizophrenia women 28.9% vs. control women 23.8%, p<0.001). However, despite high rates of CVD risk factors within the schizophrenia group, only a very small percentage (3.2% of men and 7.5% of women) of those with schizophrenia under age 55 were correctly identified as high risk for CVD according to the JBS risk algorithm. The JBS2 risk score identified only a small proportion of individuals with schizophrenia under the age of 55 as being at high risk of CVD, despite high rates of risk factors and high rates of first diagnosis of CVD within this age group. The validity of CVD risk prediction algorithms for schizophrenia needs further research. Copyright © 2014 Elsevier B.V. All rights reserved.

  20. Cognitive vulnerability to depression during middle childhood: Stability and associations with maternal affective styles and parental depression

    PubMed Central

    Hayden, Elizabeth P.; Olino, Thomas M.; Mackrell, Sarah V.M.; Jordan, Patricia L.; Desjardins, Jasmine; Katsiroumbas, Patrice

    2014-01-01

    Theories of cognitive vulnerability to depression (CVD) imply that CVD is early-emerging and trait-like; however, little longitudinal work has tested this premise in middle childhood, or examined theoretically relevant predictors of child CVD. We examined test–retest correlations of self-referent encoding task performance and self-reported attributional styles and their associations with parental characteristics in 205 seven-year-olds. At baseline, child CVD was assessed, structured clinical interviews were conducted with parents, and ratings of observed maternal affective styles were made. Children’s CVD was re-assessed approximately one and two years later. Both measures of children’s CVD were prospectively and concurrently associated with children’s depressive symptoms and showed modest stability. Multilevel modeling indicated that maternal criticism and paternal depression were related to children’s CVD. Findings indicate that even early-emerging CVD is a valid marker of children’s depression risk. PMID:25392596

  1. Correlates for cardiovascular diseases among diabetic/hypertensive patients attending outreach clinics in two Nairobi slums, Kenya

    PubMed Central

    Mugure, Gladys; Karama, Mohamed; Kyobutungi, Catherine; Karanja, Simon

    2014-01-01

    Introduction Cardiovascular diseases (CVD) are the leading cause of death in the world. Over 80% of CVD related deaths occur in low- and middle-income countries (LMICs). Diabetes and hypertension, whose prevalence in Kenya is on the rise, are major risk factors for CVD. Despite this, studies indicate that awareness on the management of risk factors for CVD among diabetic/hypertensive patients in African populations is generally low. The aim of the study was to determine the risk factors for CVD among diabetic and/or hypertensive patients attending diabetes and hypertension management clinics in Korogocho and Viwandani slums of Nairobi. Methods Data were collected using questionnaires administered to 206 diabetic/hypertensive patients attending the clinics between July 2010 and February 2011. A review of these patients’ medical records was done to determine the history of CVD outcomes such as hypertensive heart diseases, stroke and peripheral arterial diseases. Results Majority (66.5%) of the study participants were females mainly in the 51-65 age category. The study findings revealed that 73 (33.4%) respondents had CVD outcomes. In addition, 41.8% of the respondents were not aware of the causes of diabetes/hypertension. Age category 51-65 years had the highest (43.8%) number of respondents with CVD. Sex of the respondents and awareness of the link between hypertension and CVD were significantly associated with CVD outcomes (p<0.05) among the respondents. Conclusion Measures to improve awareness levels among patients at high risk of CVD outcomes are needed to complement other measures to reduce CVD risk among such patients. PMID:25852804

  2. Suicide in males and females with cardiovascular disease and comorbid depression.

    PubMed

    Hawkins, Michael; Schaffer, Ayal; Reis, Catherine; Sinyor, Mark; Herrmann, Nathan; Lanctôt, Krista L

    2016-06-01

    Myocardial infarction (MI) has been associated with an increased risk of suicide, further increased among individuals with a comorbid psychiatric illness. A paucity of studies have examined details of suicide among individuals with cardiovascular disease (CVD) and comorbid depression. We aimed to compare demographic, clinical and suicide-specific characteristics between suicide victims with CVD with depression (CVD+D) and without comorbid depression (CVD-D). Coroner data on suicide decedents with CVD (n=413) occurring in Toronto, Canada from 1998 to 2012 were collected. Characteristics were compared between the CVD+D and CVD-D groups. Regression analysis examined for gender differences in these groups. CVD+D subjects compared to CVD-D were more likely to have had a past suicide attempt (p=0.008), and to have experienced a bereavement (p=0.008) or financial stressor (p=0.005) in the past year. Each of these variables remained significantly associated with the presence of depression after the regression analysis. Within the CVD+D group, females were more likely to die from suicide by self-poisoning (p<0.0001) and males by shooting (p=0.001). Psychological autopsies were not available. The definition of CVD was broad and the accuracy of its diagnosis could not be confirmed. Individuals with CVD+D who died from suicide had significant differences in clinical characteristics and specific stressors compared to those without depression. These data may help to better characterize suicide risk and prevention in this vulnerable population. Copyright © 2016 Elsevier B.V. All rights reserved.

  3. Epidemiology of ischemic heart disease in HIV.

    PubMed

    Triant, Virginia A; Grinspoon, Steven K

    2017-11-01

    The purpose of this review is to summarize and synthesize recent data on the risk of ischemic heart disease (IHD) in HIV-infected individuals. Recent studies in the field demonstrate an increasing impact of cardiovascular disease (CVD) on morbidity and mortality in HIV relative to AIDS-related diagnoses. Studies continue to support an approximately 1.5 to two-fold increased risk of IHD conferred by HIV, with specific risk varying by sex and virologic/immunologic status. Risk factors include both traditional CVD risk factors and novel, HIV-specific factors including inflammation and immune activation. Specific antiretroviral therapy (ART) drugs may increase CVD risk, yet the net effect of ART with viral suppression is beneficial with regard to CVD risk. Management of cardiovascular risk and prevention of CVD is complex, because current general population strategies target traditional CVD risk factors only. Extensive investigation is being directed at developing tailored CVD risk prediction algorithms and interventions to reduce CVD risk in HIV. Increased IHD risk is a significant clinical and public health challenge in HIV. The development and application of HIV-specific interventions to manage CVD risk factors and reduce CVD risk will improve the long-term health of this ageing population.

  4. Acarbose treatment and the risk of cardiovascular disease in type 2 diabetic patients: a nationwide seven-year follow-up study.

    PubMed

    Chen, Jui-Ming; Chang, Cheng-Wei; Lin, Ying-Chieh; Horng, Jorng-Tzong; Sheu, Wayne H-H

    2014-01-01

    To investigate the potential benefits of acarbose treatment on cardiovascular disease (CVD) in patients with type 2 diabetes by using nationwide insurance claim dataset. Among 644,792 newly diagnosed type 2 diabetic patients without preexisting CVD in a nationwide cohort study, 109,139 (16.9%) who had received acarbose treatment were analyzed for CVD risk. Those with CVD followed by acarbose therapy were also subjected to analysis. During 7 years of follow-up, 5,081 patients (4.7%) developed CVD. The crude hazard ratio (HR) and adjusted HR were 0.66 and 0.99, respectively. The adjusted HR of CVD was 1.19, 0.70, and 0.38 when the duration of acarbose use was <12 months, 12-24 months, and >24 months, respectively. Adjusted HR was 1.14, 0.64, and 0.41 with acarbose cumulative doses <54,750 mg, 54,751 to 109,500 mg, and >109,500 mg, respectively. In patients with type 2 diabetes without preexisting CVD, treatment with acarbose showed a transient increase in incidence of CVD in the initial 12 months followed by significant reductions of CVD in prolonged acarbose users. After the first CVD events, continuous use of acarbose revealed neutral effect within the first 12 months. The underlying mechanisms require further investigations.

  5. N-terminal pro-brain-type natriuretic peptide (NT-pro-BNP) and mortality risk in early inflammatory polyarthritis: results from the Norfolk Arthritis Registry (NOAR)

    PubMed Central

    Mirjafari, Hoda; Welsh, Paul; Verstappen, Suzanne M M; Wilson, Paddy; Marshall, Tarnya; Edlin, Helena; Bunn, Diane; Chipping, Jacqueline; Lunt, Mark; Symmons, Deborah P M; Sattar, Naveed; Bruce, Ian N

    2014-01-01

    Background We measured N-terminal pro-brain natriuretic peptide (NT-pro-BNP), a marker of cardiac dysfunction, in an inception cohort with early inflammatory polyarthritis (IP) and assessed its association with disease phenotype, cardiovascular disease (CVD), all-cause and CVD related mortality. Methods Subjects with early IP were recruited to the Norfolk Arthritis Register from January 2000 to December 2008 and followed up to death or until March 2010 including any data from the national death register. The associations of baseline NT-pro-BNP with IP related factors and CVD were assessed by linear regression. Cox proportional hazards models examined the independent association of baseline NT-pro-BNP with all-cause and CVD mortality. Results We studied 960 early IP subjects; 163 (17%) had prior CVD. 373 (39%) patients had a baseline NT-pro-BNP levels ≥100 pg/ml. NT-pro-BNP was associated with age, female gender, HAQ score, CRP, current smoking, history of hypertension, prior CVD and the presence of carotid plaque. 92 (10%) IP subjects died including 31 (3%) from CVD. In an age and gender adjusted analysis, having a raised NT-pro-BNP level (≥100 pg/ml) was associated with both all-cause and CVD mortality (adjusted HR (95% CI) 2.36 (1.42 to 3.94) and 3.40 (1.28 to 9.03), respectively). These findings were robust to adjustment for conventional CVD risk factors and prevalent CVD. Conclusions In early IP patients, elevated NT-pro-BNP is related to HAQ and CRP and predicts all-cause and CVD mortality independently of conventional CVD risk factors. Further study is required to identify whether NT-pro-BNP may be clinically useful in targeting intensive interventions to IP patients at greatest risk of CVD. PMID:23511225

  6. Alzheimer biomarkers and clinical Alzheimer disease were not associated with increased cerebrovascular disease in a memory clinic population.

    PubMed

    Spies, Petra E; Verbeek, Marcel M; Sjogren, Magnus J C; de Leeuw, Frank-Erik; Claassen, Jurgen A H R

    2014-01-01

    Preclinical and post-mortem studies suggest that Alzheimer disease (AD) causes cerebrovascular dysfunction, and therefore may enhance susceptibility to cerebrovascular disease (CVD). The objective of this study was to investigate this association in a memory clinic population. The AD biomarkers CSF amyloid β42, amyloid β40 and APOE-ε4 status have all been linked to increased CVD risk in AD, and therefore the first aim of this study was to analyze the association between these biomarkers and CVD. In 92 memory clinic patients the cross-sectional association between AD biomarkersand the severity of CVD was investigated with linear regression analysis. Additionally, we studied whether AD biomarkers modified the relation between vascular risk factors and CVD. CVD was assessed on MRI through a visual rating scale.Analyses were adjusted for age. The second aim of this study was to investigate the association between clinical AD and CVD, where 'clinical AD' was defined as follows: impairment in episodic memory, hippocampal atrophy and an aberrant concentration of cerebrospinal fluid (CSF) biomarkers. 47 of the 92 patients had AD. No association between CSF amyloid β42, amyloid β40 or APOE-ε4 status and CVD severity was found, nor did these AD biomarkers modify the relation between vascular risk factors and CVD. Clinical AD was not associated with CVD severity (p=0.83). Patients with more vascular risk factors had more CVD, but this relationship was not convincingly modified by AD (p=0.06). In this memory clinic population, CVD in patients with AD was related to vascular risk factors and age, comparable to patients without AD. Therefore, in our study, the preclinical and post-mortem evidence that AD would predispose to CVD could not be translated clinically. Further work, including replication of this work in a different and larger sample, is warranted.

  7. Prediction of cardiovascular risk in rheumatoid arthritis: performance of original and adapted SCORE algorithms.

    PubMed

    Arts, E E A; Popa, C D; Den Broeder, A A; Donders, R; Sandoo, A; Toms, T; Rollefstad, S; Ikdahl, E; Semb, A G; Kitas, G D; Van Riel, P L C M; Fransen, J

    2016-04-01

    Predictive performance of cardiovascular disease (CVD) risk calculators appears suboptimal in rheumatoid arthritis (RA). A disease-specific CVD risk algorithm may improve CVD risk prediction in RA. The objectives of this study are to adapt the Systematic COronary Risk Evaluation (SCORE) algorithm with determinants of CVD risk in RA and to assess the accuracy of CVD risk prediction calculated with the adapted SCORE algorithm. Data from the Nijmegen early RA inception cohort were used. The primary outcome was first CVD events. The SCORE algorithm was recalibrated by reweighing included traditional CVD risk factors and adapted by adding other potential predictors of CVD. Predictive performance of the recalibrated and adapted SCORE algorithms was assessed and the adapted SCORE was externally validated. Of the 1016 included patients with RA, 103 patients experienced a CVD event. Discriminatory ability was comparable across the original, recalibrated and adapted SCORE algorithms. The Hosmer-Lemeshow test results indicated that all three algorithms provided poor model fit (p<0.05) for the Nijmegen and external validation cohort. The adapted SCORE algorithm mainly improves CVD risk estimation in non-event cases and does not show a clear advantage in reclassifying patients with RA who develop CVD (event cases) into more appropriate risk groups. This study demonstrates for the first time that adaptations of the SCORE algorithm do not provide sufficient improvement in risk prediction of future CVD in RA to serve as an appropriate alternative to the original SCORE. Risk assessment using the original SCORE algorithm may underestimate CVD risk in patients with RA. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  8. Carotid Plaque Score and Risk of Cardiovascular Mortality in the Oldest Old: Results from the TOOTH Study.

    PubMed

    Hirata, Takumi; Arai, Yasumichi; Takayama, Michiyo; Abe, Yukiko; Ohkuma, Kiyoshi; Takebayashi, Toru

    2018-01-01

    Accumulating evidence suggests that predictability of traditional cardiovascular risk factors declines with advancing age. We investigated whether carotid plaque scores (CPSs) were associated with cardiovascular disease (CVD) death in the oldest old, and whether asymmetrical dimethylarginine (ADMA), a marker of endothelial dysfunction, moderated the association between the CPS and CVD death. We conducted a prospective cohort study of Japanese subjects aged ≥85 years without CVD at baseline. We followed this cohort for 6 years to investigate the association of CPS with CVD death via multivariable Cox proportional hazard analysis. We divided participants into three groups according to CPS (no, 0 points; low, 1.2-4.9 points; high, ≥5.0 points). The predictive value of CPS for estimating CVD death risk over CVD risk factors, including ADMA, was examined using C-statistics. We analyzed 347 participants (151 men, 196 women; mean age, 87.6 years), of which 135 (38.9%) had no carotid plaque at baseline, and 48 (13.8%) had high CPS. Of the total, 29 (8.4%) participants experienced CVD-related death during the study period. Multivariable analysis revealed a significant association of high CPS with CVD-related mortality relative to no CPS (hazard ratio, 3.90; 95% confidence interval: 1.47-10.39). ADMA was not associated with CVD death, but the significant association between CPS and CVD death was observed only in lower ADMA level. The addition of CPS to other risk factors improved the predictability of CVD death (p=0.032). High CPS correlated significantly with a higher CVD death risk in the oldest old with low cardiovascular risk. Ultrasound carotid plaque evaluation might facilitate risk evaluations of CVD death in the very old.

  9. Plasma and blood viscosity in the prediction of cardiovascular disease and mortality in the Scottish Heart Health Extended Cohort Study.

    PubMed

    Peters, Sanne Ae; Woodward, Mark; Rumley, Ann; Tunstall-Pedoe, Hugh D; Lowe, Gordon DO

    2017-01-01

    Background There is increasing evidence that blood viscosity and its major determinants (haematocrit and plasma viscosity) are associated with increased risks of cardiovascular disease (CVD) and premature mortality; however, their predictive value for CVD and mortality is not clear. Methods We prospectively assessed the added predictive value of plasma viscosity and whole blood viscosity and haematocrit in 3386 men and women aged 30-74 years participating in the Scottish Heart Health Extended Cohort study. Results Over a median follow-up of 17 years, 819 CVD events and 778 deaths were recorded. Hazard ratios (95% confidence intervals) for a 1 SD increase in plasma viscosity, adjusted for major CVD risk factors, were 1.12 (1.04-1.20) for CVD and 1.20 (1.12-1.29) for mortality. These remained significant after further adjustment for plasma fibrinogen: 1.09 (1.01-1.18) and 1.13 (1.04-1.22). The corresponding results for blood viscosity were 0.99 (0.90, 1.09) for CVD, and 1.11 (1.01, 1.22) for total mortality after adjustment for major CVD risk factors; and 0.97 (0.88, 1.08) and 1.06 (0.96, 1.18) after further adjustment for fibrinogen. Haematocrit showed similar associations to blood viscosity. When added to classical CVD risk factors, plasma viscosity improved the discrimination of CVD and mortality by 2.4% (0.7-4.4%) and 4.1% (2.0-6.5%). Conclusions Although plasma and blood viscosity may have a role in the pathogenesis of CVD and mortality, much of their association with CVD and mortality is due to the mutual effects of major CVD risk factors. However, plasma viscosity adds to the discrimination of CVD and mortality and might be considered for inclusion in multivariable risk scores.

  10. CVD silicon carbide monofilament reinforced SrO-Al2O3-2SiO2 (SAS) glass-ceramic composites

    NASA Technical Reports Server (NTRS)

    Bansal, Narottam P.

    1995-01-01

    Unidirectional CVD SiC fiber-reinforced SrO.Al2O3.2SiO2 (SAS) glass-ceramic matrix composites have been fabricated by hot pressing at various combinations of temperature, pressure and time. Both carbon-rich surface coated SCS-6 and uncoated SCS-0 fibers were used as reinforcements. Almost fully dense composites have been obtained. Monoclinic celsian, SrAl2Si2O8, was the only crystalline phase observed in the matrix from x-ray diffraction. During three point flexure testing of composites, a test span to thickness ratio of approximately 25 or greater was necessary to avoid sample delamination. Strong and tough SCS-6/SAS composites having a first matrix crack stress of approximately 300 MPa and an ultimate bend strength of approximately 825 MPa were fabricated. No chemical reaction between the SCS-6 fibers and the SAS matrix was observed after high temperature processing. The uncoated SCS-0 fiber-reinforced SAS composites showed only limited improvement in strength over SAS monolithic. The SCS-0/SAS composite having a fiber volume fraction of 0.24 and hot pressed at 1400 deg C exhibited a first matrix cracking stress of approximately 231 +/- 20 MPa and ultimate strength of 265 +/- 17 MPa. From fiber push-out tests, the fiber/matrix interfacial debonding strength (tau(sub debond)) and frictional sliding stress (tau(sub friction)) in the SCS-6/SAS system were evaluated to be approximately 6.7 +/- 2.3 MPa and 4.3 +/- 0.6 MPa, respectively, indicating a weak interface. However, for the SCS-0/SAS composite, much higher values of approximately 17.5 +/- 2.7 MPa for tau(sub debond) and 11.3 +/- 1.6 MPa for tau(sub friction) respectively, were observed; some of the fibers were so strongly bonded to the matrix that they could not be pushed out. Examination of fracture surfaces revealed limited short pull-out length of SCS-0 fibers. The applicability of various micromechanical models for predicting the values of first matrix cracking stress and ultimate strength of these

  11. Cerebrovascular disease, beta-amyloid and cognition in aging

    PubMed Central

    Marchant, Natalie L.; Reed, Bruce R.; DeCarli, Charles S.; Madison, Cindee M.; Weiner, Michael W.; Chui, Helena C.; Jagust, William J.

    2011-01-01

    The present study evaluated cerebrovascular disease (CVD), β-amyloid (Aβ), and cognition in clinically normal elderly adults. Fifty-four participants underwent MRI, PIB-PET imaging, and neuropsychological evaluation. High white matter hyperintensity burden and/or presence of infarct defined CVD status (CVD−: N = 27; CVD+: N = 27). PIB-PET ratios of Aβ deposition were extracted using Logan plotting (cerebellar reference). Presence of high levels of Aβ in prespecified regions determined PIB status (PIB−: N = 33; PIB+: N = 21). Executive functioning and episodic memory were measured using composite scales. CVD and Aβ, defined as dichotomous or continuous variables, were unrelated to one another. CVD+ participants showed lower executive functioning (P = 0.001) when compared to CVD− individuals. Neither PIB status nor amount of Aβ affected cognition (Ps ≥ .45), and there was no statistical interaction between CVD and PIB on either cognitive measure. Within this spectrum of normal aging CVD and Aβ aggregation appear to be independent processes with CVD primarily affecting cognition. PMID:22048124

  12. Friction and Wear of Ion-Beam-Deposited Diamondlike Carbon on Chemical-Vapor-Deposited, Fine-Grain Diamond

    NASA Technical Reports Server (NTRS)

    Miyoshi, Kazuhisa; Wu, Richard L. C.; Lanter, William C.

    1996-01-01

    Friction and wear behavior of ion-beam-deposited diamondlike carbon (DLC) films coated on chemical-vapor-deposited (CVD), fine-grain diamond coatings were examined in ultrahigh vacuum, dry nitrogen, and humid air environments. The DLC films were produced by the direct impact of an ion beam (composed of a 3:17 mixture of Ar and CH4) at ion energies of 1500 and 700 eV and an RF power of 99 W. Sliding friction experiments were conducted with hemispherical CVD diamond pins sliding on four different carbon-base coating systems: DLC films on CVD diamond; DLC films on silicon; as-deposited, fine-grain CVD diamond; and carbon-ion-implanted, fine-grain CVD diamond on silicon. Results indicate that in ultrahigh vacuum the ion-beam-deposited DLC films on fine-grain CVD diamond (similar to the ion-implanted CVD diamond) greatly decrease both the friction and wear of fine-grain CVD diamond films and provide solid lubrication. In dry nitrogen and in humid air, ion-beam-deposited DLC films on fine-grain CVD diamond films also had a low steady-state coefficient of friction and a low wear rate. These tribological performance benefits, coupled with a wider range of coating thicknesses, led to longer endurance life and improved wear resistance for the DLC deposited on fine-grain CVD diamond in comparison to the ion-implanted diamond films. Thus, DLC deposited on fine-grain CVD diamond films can be an effective wear-resistant, lubricating coating regardless of environment.

  13. Crystal-proven Gout and Characteristic Gout Severity Factors are Associated with Cardiovascular Disease.

    PubMed

    Disveld, Iris J M; Fransen, Jaap; Rongen, Gerard A; Kienhorst, Laura B E; Zoakman, Sahel; Janssens, Hein J E M; Janssen, Matthijs

    2018-04-15

    Our aim was to examine the prevalence of cardiovascular disease (CVD) in patients with crystal-proven gout compared to arthritis controls. Further, we analyzed the association between characteristic gout severity factors and CVD to provide further support for a pathogenetic relationship between gout and CVD. Patients with arthritis referred for diagnosis were consecutively included in the Gout Arnhem-Liemers cohort. Joint fluid analysis was performed in all referred patients; controls were negative for crystals. Patients' characteristics and different manifestations of CVD and gout severity factors (disease duration, attack frequency, tophi, affected joints, high serum urate acid level, joint damage) were collected. Gout patients were compared with controls for the prevalence of CVD. In addition, the association between characteristic gout severity factors and presence of CVD was analyzed. Data from 700 gout patients and 276 controls were collected. CVD was present in 47% (95% CI 44%-51%) and 24% (95% CI 19%-29%) of gout patients and controls, respectively. Corrected for confounders, gout was still strongly associated with an increased prevalence of CVD compared to controls (OR 3.39, 95% CI 2.37-4.84). In patients with gout, disease duration ≥ 2 years, oligo- or polyarthritis, serum urate acid > 0.55 mmol/l at presentation, and joint damage were independently (p < 0.05) associated with prevalent CVD. Crystal-proven gout was strongly associated with an increased prevalence of CVD. In patients with gout, characteristic gout severity factors were associated with CVD.

  14. Density of calcium in the ascending thoracic aorta and risk of incident cardiovascular disease events.

    PubMed

    Thomas, Isac C; McClelland, Robyn L; Michos, Erin D; Allison, Matthew A; Forbang, Nketi I; Longstreth, W T; Post, Wendy S; Wong, Nathan D; Budoff, Matthew J; Criqui, Michael H

    2017-10-01

    The volume and density of coronary artery calcium (CAC) both independently predict cardiovascular disease (CVD) beyond standard risk factors, with CAC density inversely associated with incident CVD after accounting for CAC volume. We tested the hypothesis that ascending thoracic aorta calcium (ATAC) volume and density predict incident CVD events independently of CAC. The Multi-Ethnic Study of Atherosclerosis (MESA) is a prospective cohort study of participants without clinical CVD at baseline. ATAC and CAC were measured from baseline cardiac computed tomography (CT). Cox regression models were used to estimate the associations of ATAC volume and density with incident coronary heart disease (CHD) events and CVD events, after adjustment for standard CVD risk factors and CAC volume and density. Among 6811 participants, 234 (3.4%) had prevalent ATAC and 3395 (49.8%) had prevalent CAC. Over 10.3 years, 355 CHD and 562 CVD events occurred. One-standard deviation higher ATAC density was associated with a lower risk of CHD (HR 0.48 [95% CI 0.29-0.79], p<0.01) and CVD (HR 0.56 [0.37-0.84], p<0.01) after full adjustment. ATAC volume was not associated with outcomes after full adjustment. ATAC was uncommon in a cohort free of clinical CVD at baseline. However, ATAC density was inversely associated with incident CHD and CVD after adjustment for CVD risk factors and CAC volume and density. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. Mortality from cardiovascular diseases in Bavi District, Vietnam.

    PubMed

    Minh, Hoang Van; Byass, Peter; Wall, Stig

    2003-01-01

    Like other developing countries, Vietnam is undergoing epidemiological transition, which is characterized by many changes in terms of morbidity and mortality patterns. The fact that cardiovascular diseases (CVD) are leading causes of death in hospitals in the whole country was ascertained from annual statistics. However, the magnitude of the burden of mortality from CVD at the community level remained unknown. The aims of the study were to outline CVD mortality during health transition in a rural community in the north of Vietnam and to examine associations between CVD mortality and the socioeconomic status of the population. Within an established demographic surveillance system (DSS), verbal autopsy (VA) was used to identify the burden of mortality from CVD. Cohort analysis was used in this study to measure associations between CVD mortality and socioeconomic determinants. CVD emerged as a leading cause of death in the study area, accounting for more than infectious and parasitic diseases combined. CVD killed many people among the most economically productive age group, both men and women, in all socioeconomic groups. Occupational status was shown to be significantly associated with CVD mortality. Already at this point in the epidemiological transition, there is evidence of a substantial burden of CVD in rural Vietnam. Although this study was not able to show trends, the current situation is a cause for concern in health policy and planning. Verbal autopsy methods and CVD risk factor evaluations will form important parts of future research agendas.

  16. Circulating Branched-Chain Amino Acids and Incident Cardiovascular Disease in a Prospective Cohort of US Women.

    PubMed

    Tobias, Deirdre K; Lawler, Patrick R; Harada, Paulo H; Demler, Olga V; Ridker, Paul M; Manson, JoAnn E; Cheng, Susan; Mora, Samia

    2018-04-01

    Circulating branched-chain amino acids (BCAAs; isoleucine, leucine, and valine) are strong predictors of type 2 diabetes mellitus (T2D), but their association with cardiovascular disease (CVD) is uncertain. We hypothesized that plasma BCAAs are positively associated with CVD risk and evaluated whether this was dependent on an intermediate diagnosis of T2D. Participants in the Women's Health Study prospective cohort were eligible if free of CVD at baseline blood collection (n=27 041). Plasma metabolites were measured via nuclear magnetic resonance spectroscopy. Multivariable Cox regression models estimated hazard ratios (HRs) and 95% confidence intervals (CIs) for BCAAs with incident CVD (myocardial infarction, stroke, and coronary revascularization). We confirmed 2207 CVD events over a mean 18.6 years of follow-up. Adjusting for age, body mass index, and other established CVD risk factors, total BCAAs were positively associated with CVD (per SD: HR, 1.13; 95% CI, 1.08-1.18), comparable to LDL-C (low-density lipoprotein cholesterol) with CVD (per SD: HR, 1.12; 95% CI, 1.07-1.17). BCAAs were associated with coronary events (myocardial infarction: HR, 1.16; 95% CI, 1.06-1.26; revascularization: HR, 1.17; 95% CI, 1.11-1.25), and borderline significant association with stroke (HR, 1.07; 95% CI, 0.99-1.15). The BCAA-CVD association was greater ( P interaction=0.036) among women who developed T2D before CVD (HR, 1.20; 95% CI, 1.08-1.32) versus women without T2D (HR, 1.08; 95% CI, 1.03-1.14). Adjusting for LDL-C, an established CVD risk factor, did not attenuate these findings; however, adjusting for HbA1c and insulin resistance eliminated the associations of BCAAs with CVD. Circulating plasma BCAAs were positively associated with incident CVD in women. Impaired BCAA metabolism may capture the long-term risk of the common cause underlying T2D and CVD. © 2018 American Heart Association, Inc.

  17. Role of pharmacist in cardiovascular disease-related health promotion and in hypertension and dyslipidemia management: a cross-sectional study in the State of Qatar.

    PubMed

    El Hajj, Maguy Saffouh; Mahfoud, Ziyad R; Al Suwaidi, Jassim; Alkhiyami, Dania; Alasmar, Aya Riyad

    2016-06-01

    In Qatar, cardiovascular diseases (CVD) have recently become the leading cause of morbidity and mortality. Prevention, detection and management of CVD risk factors reduce CVD chance. The study objectives were to assess Qatar pharmacists' involvement in CVD health promotion, to identify the activities that they currently provide to patients with CVD risk factors, to describe their attitudes towards their involvement in CVD prevention and to assess their perceived barriers for provision of CVD prevention services We conducted a cross-sectional survey of community and ambulatory pharmacists in Qatar. Pharmacist characteristics, involvement in CVD-related activities along with their attitudes and perceived barriers were analysed using frequency distributions. Bivariate linear regression models were used to test for associations between CVD health promotion activity score and each variable. Variables with a P-value of 0.20 or less were included in the multivariate model. A total of 141 pharmacists completed the survey (response rate 60%). More than 70% responded with rarely or never to 6 out of the 10 CVD health promotion activities. Eighty-four per cent and 68% always or often describe to patients the appropriate time to take antihypertensive medications and the common medication adverse effects, respectively. Yet, 50% rarely or never review the medication refill history or provide adherence interventions. Lack of CVD educational materials was the top perceived barrier (55%) in addition to lack of having private counselling area (44.6%), and lack of time (38.3%). Females and community pharmacists were more involved in CVD health promotion (P = 0.046 and P = 0.017, respectively) than their counterparts. Health promotion practice increased with increasing attitudes score and decreased with increased barriers score (P = 0.012 and P = 0.001). The scope of pharmacy practice in CVD prevention is limited in Qatar. Efforts need to be exerted to increase

  18. Saturated Fatty Acids and Cardiovascular Disease: Replacements for Saturated Fat to Reduce Cardiovascular Risk

    PubMed Central

    Briggs, Michelle A.; Petersen, Kristina S.; Kris-Etherton, Penny M.

    2017-01-01

    Dietary recommendations to decrease the risk of cardiovascular disease (CVD) have focused on reducing intake of saturated fatty acids (SFA) for more than 50 years. While the 2015–2020 Dietary Guidelines for Americans advise substituting both monounsaturated and polyunsaturated fatty acids for SFA, evidence supports other nutrient substitutions that will also reduce CVD risk. For example, replacing SFA with whole grains, but not refined carbohydrates, reduces CVD risk. Replacing SFA with protein, especially plant protein, may also reduce CVD risk. While dairy fat (milk, cheese) is associated with a slightly lower CVD risk compared to meat, dairy fat results in a significantly greater CVD risk relative to unsaturated fatty acids. As research continues, we will refine our understanding of dietary patterns associated with lower CVD risk. PMID:28635680

  19. Small artery elasticity predicts future cardiovascular events in chinese patients with angiographic coronary artery disease.

    PubMed

    Wan, Zhaofei; Liu, Xiaojun; Wang, Xinhong; Liu, Fuqiang; Liu, Weimin; Wu, Yue; Pei, Leilei; Yuan, Zuyi

    2014-04-01

    Arterial elasticity has been shown to predict cardiovascular disease (CVD) in apparently healthy populations. The present study aimed to explore whether arterial elasticity could predict CVD events in Chinese patients with angiographic coronary artery disease (CAD). Arterial elasticity of 365 patients with angiographic CAD was measured. During follow-up (48 months; range 6-65), 140 CVD events occurred (including 34 deaths). Univariate Cox analysis demonstrated that both large arterial elasticity and small arterial elasticity were significant predictors of CVD events. Multivariate Cox analysis indicated that small arterial elasticity remained significant. Kaplan-Meier analysis showed that the probability of having a CVD event/CVD death increased with a decrease of small arterial elasticity (P < .001, respectively). Decreased small arterial elasticity independently predicts the risk of CVD events in Chinese patients with angiographic CAD.

  20. Evolution of Cardiovascular Disease During the Transition to End-Stage Renal Disease.

    PubMed

    Bansal, Nisha

    2017-03-01

    Cardiovascular disease (CVD) remains the leading cause of morbidity and mortality in patients with chronic kidney disease (CKD) and end-stage renal disease (ESRD). The rate of death in incident dialysis patients remains high. This has led to interest in the study of the evolution of CVD during the critical transition period from CKD to ESRD. Understanding the natural history and risk factors of clinical and subclinical CVD during this transition may help guide the timing of appropriate CVD therapies to improve outcomes in patients with kidney disease. This review provides an overview of the epidemiology of subclinical and clinical CVD during the transition from CKD to ESRD and discusses clinical trials of CVD therapies to mitigate risk of CVD in CKD and ESRD patients. Copyright © 2017 Elsevier Inc. All rights reserved.

  1. S1-Leitlinie Lipödem.

    PubMed

    Reich-Schupke, Stefanie; Schmeller, Wilfried; Brauer, Wolfgang Justus; Cornely, Manuel E; Faerber, Gabriele; Ludwig, Malte; Lulay, Gerd; Miller, Anya; Rapprich, Stefan; Richter, Dirk Frank; Schacht, Vivien; Schrader, Klaus; Stücker, Markus; Ure, Christian

    2017-07-01

    Die vorliegende überarbeitete Leitlinie zum Lipödem wurde unter der Federführung der Deutschen Gesellschaft für Phlebologie (DGP) erstellt und finanziert. Die Inhalte beruhen auf einer systematischen Literaturrecherche und dem Konsens von acht medizinischen Fachgesellschaften und Berufsverbänden. Die Leitlinie beinhaltet Empfehlungen zu Diagnostik und Therapie des Lipödems. Die Diagnose ist dabei auf der Basis von Anamnese und klinischem Befund zu stellen. Charakteristisch ist eine umschriebene, symmetrisch lokalisierte Vermehrung des Unterhautfettgewebes an den Extremitäten mit deutlicher Disproportion zum Stamm. Zusätzlich finden sich Ödeme, Hämatomneigung und eine gesteigerte Schmerzhaftigkeit der betroffenen Körperabschnitte. Weitere apparative Untersuchungen sind bisher besonderen Fragestellungen vorbehalten. Die Erkrankung ist chronisch progredient mit individuell unterschiedlichem und nicht vorhersehbarem Verlauf. Die Therapie besteht aus vier Säulen, die individuell kombiniert und an das aktuelle Beschwerdebild angepasst werden sollten: komplexe physikalische Entstauungstherapie (manuelle Lymphdrainage, Kompressionstherapie, Bewegungstherapie, Hautpflege), Liposuktion und plastisch-chirurgische Interventionen, Ernährung und körperliche Aktivität sowie ggf. additive Psychotherapie. Operative Maßnahmen sind insbesondere dann angezeigt, wenn trotz konsequent durchgeführter konservativer Therapie noch Beschwerden bestehen bzw. eine Progredienz des Befundes und/oder der Beschwerden auftritt. Eine begleitend zum Lipödem bestehende morbide Adipositas sollte vor einer Liposuktion therapeutisch angegangen werden. © 2017 The Authors | Journal compilation © Blackwell Verlag GmbH, Berlin.

  2. Dietary antioxidant capacity of the patients with cardiovascular disease in a cross-sectional study.

    PubMed

    Zujko, Małgorzata E; Witkowska, Anna M; Waśkiewicz, Anna; Piotrowski, Walerian; Terlikowska, Katarzyna M

    2015-03-15

    The purpose of this study was to establish sources and patterns of antioxidant, polyphenol and flavonoid intakes in men and women with cardiovascular disease (CVD). The subjects with CVD and healthy controls (HC) were participants of the Polish National Multicenter Health Survey (WOBASZ). Food intakes were measured with the 1-day 24-hour recall method. A self-developed database was used to calculate dietary total antioxidant capacity (DTAC), dietary total polyphenol content (DTPC) and dietary total flavonoid content (DTFC). DTAC did not differ between the men with CVD and HC men (6442 vs. 6066 μmol trolox equivalents - TE), but in the women with CVD it was significantly higher than in the HC women (6182 vs. 5500 μmol TE). The main sources of antioxidants in the males with CVD were: tea, coffee, apples, and nuts and seeds, and tea, coffee and apples in HC. In the females they were: tea, coffee, apples and strawberries, both in the women with CVD and HC. DTPC in the men with CVD did not differ from HC (1198 vs. 1114 mg gallic acid equivalents, GAE). In the females, DTPC was significantly higher in the subjects with CVD as compared to HC (1075 vs. 981 mg GAE). Predominant sources of polyphenols were: tea, coffee, cabbage, potatoes, apples and white bread in the men with CVD, and tea, coffee, potatoes, white bread and apples in HC, while in the women (both with CVD and HC): tea, coffee, apples, potatoes and cabbage. No differences in DTFC have been found between the males with CVD and HC (212 vs. 202 mg quercetine equivalents, QE). In the women with CVD, DTFC was significantly higher than in HC (200 vs. 177 mg QE). Main sources of flavonoids in all participants (men and women, CVD and HC) were tea, apples, cabbage and coffee. Polish men and women faced with CVD beneficially modify their dietary practices by enhancing intakes of foods that are sources of antioxidants, polyphenols and flavonoids. Different sources and patterns of antioxidant, polyphenol and flavonoid

  3. Screening for Cardiovascular Disease Risk With Electrocardiography: US Preventive Services Task Force Recommendation Statement.

    PubMed

    Curry, Susan J; Krist, Alex H; Owens, Douglas K; Barry, Michael J; Caughey, Aaron B; Davidson, Karina W; Doubeni, Chyke A; Epling, John W; Kemper, Alex R; Kubik, Martha; Landefeld, C Seth; Mangione, Carol M; Silverstein, Michael; Simon, Melissa A; Tseng, Chien-Wen; Wong, John B

    2018-06-12

    Cardiovascular disease (CVD), which encompasses atherosclerotic conditions such as coronary heart disease, cerebrovascular disease, and peripheral arterial disease, is the most common cause of death among adults in the United States. Treatment to prevent CVD events by modifying risk factors is currently informed by CVD risk assessment with tools such as the Framingham Risk Score or the Pooled Cohort Equations, which stratify individual risk to inform treatment decisions. To update the 2012 US Preventive Services Task Force (USPSTF) recommendation on screening for coronary heart disease with electrocardiography (ECG). The USPSTF reviewed the evidence on whether screening with resting or exercise ECG improves health outcomes compared with the use of traditional CVD risk assessment alone in asymptomatic adults. For asymptomatic adults at low risk of CVD events (individuals with a 10-year CVD event risk less than 10%), it is very unlikely that the information from resting or exercise ECG (beyond that obtained with conventional CVD risk factors) will result in a change in the patient's risk category as assessed by the Framingham Risk Score or Pooled Cohort Equations that would lead to a change in treatment and ultimately improve health outcomes. Possible harms are associated with screening with resting or exercise ECG, specifically the potential adverse effects of subsequent invasive testing. For asymptomatic adults at intermediate or high risk of CVD events, there is insufficient evidence to determine the extent to which information from resting or exercise ECG adds to current CVD risk assessment models and whether information from the ECG results in a change in risk management and ultimately reduces CVD events. As with low-risk adults, possible harms are associated with screening with resting or exercise ECG in asymptomatic adults at intermediate or high risk of CVD events. The USPSTF recommends against screening with resting or exercise ECG to prevent CVD events in

  4. Sick Populations and Sick Subpopulations: Reducing Disparities in Cardiovascular Disease Between Blacks and Whites in the United States.

    PubMed

    Lu, Yuan; Ezzati, Majid; Rimm, Eric B; Hajifathalian, Kaveh; Ueda, Peter; Danaei, Goodarz

    2016-08-09

    Cardiovascular disease (CVD) death rates are much higher in blacks than whites in the United States. It is unclear how CVD risk and events are distributed among blacks versus whites and how interventions reduce racial disparities. We developed risk models for fatal and for fatal and nonfatal CVD using 8 cohorts in the United States. We used 6154 adults who were 50 to 69 years of age in the National Health and Nutrition Examination Survey 1999 to 2012 to estimate the distributions of risk and events in blacks and whites. We estimated the total and disparity impacts of a range of population-wide, targeted, and risk-based interventions on 10-year CVD risks and event rates. Twenty-five percent (95% confidence interval [CI], 22-28) of black men and 12% (95% CI, 10-14) of black women were at ≥6.67% risk of fatal CVD (almost equivalent to 20% risk of fatal or nonfatal CVD) compared with 10% (95% CI, 8-12) of white men and 3% (95% CI, 2-4) of white women. These high-risk individuals accounted for 55% (95% CI, 49-59) of CVD deaths among black men and 42% (95% CI, 35-46) in black women compared with 30% (95% CI, 24-35) in white men and 18% (95% CI, 13-22) in white women. We estimated that an intervention that treated multiple risk factors in high-risk individuals could reduce black-white difference in CVD death rate from 1659 to 1244 per 100 000 in men and from 1320 to 897 in women. Rates of fatal and nonfatal CVD were generally similar between black and white men. In women, a larger proportion of women were at ≥7.5% risk of CVD (30% versus 19% in whites), and an intervention that targeted multiple risk factors among this group was estimated to reduce black-white differences in CVD rates from 1688 to 1197 per 100 000. A substantially larger proportion of blacks have a high risk of fatal CVD and bear a large share of CVD deaths. A risk-based intervention that reduces multiple risk factors could substantially reduce overall CVD rates and racial disparities in CVD death

  5. Racial disparities in age at time of cardiovascular events and cardiovascular-related death in patients with systemic lupus erythematosus.

    PubMed

    Scalzi, Lisabeth V; Hollenbeak, Christopher S; Wang, Li

    2010-09-01

    To determine whether racial disparities exist with regard to the age at which patients with systemic lupus erythematosus (SLE) experience cardiovascular disease (CVD) and CVD-associated death. Using the 2003-2006 Nationwide Inpatient Sample, we calculated the age difference between patients with SLE and their race- and sex-matched controls at the time of hospitalization for a cardiovascular event and for CVD-associated death. In addition, we calculated the age difference between white patients with SLE and sex-matched controls for each minority group for the same outcomes. The mean age difference between women with and those without SLE at the time of admission for a CVD event was 10.5 years. All age differences between women with SLE (n = 3,627) and women without SLE admitted for CVD were significant (P < 0.0001). Among different racial groups with SLE, black women were the youngest to be admitted with CVD (53.9 years) and to have a CVD-associated in-hospital death (52.8 years; n = 218). Black women with SLE were 19.8 years younger than race- and sex-matched controls at the time of CVD-associated death. Admission trends for CVD were reversed for black women, such that the highest proportions of these patients were admitted before age 55 years, and then the proportions steadily decreased across age categories. Among the 805 men with SLE who were admitted with a CVD event, those who were black or Hispanic were youngest. There are significant racial disparities with regard to age at the time of hospital admission for CVD events and CVD-related hospitalization resulting in death in patients with SLE.

  6. Perceived and actual risk of cardiovascular disease in patients with rheumatoid arthritis in Korea: A cross-sectional study.

    PubMed

    Boo, Sunjoo; Froelicher, Erika S; Yun, Ju-Hui; Kim, Ye-Won; Jung, Ju-Yang; Suh, Chang-Hee

    2016-10-01

    The purposes of this study were to compare the perceived and actual 10-year risk for cardiovascular disease (CVD) and to evaluate the influence of cardiovascular risk factors on perceived CVD risk in patients with rheumatoid arthritis (RA) in Korea. Additionally, the attainment of CVD prevention guideline goals by 3 levels of CVD risk (low, moderate, and high) was presented.For this cross-sectional study, data were collected from 208 patients with RA. Actual CVD risk was estimated with the Systematic Coronary Risk Evaluation (SCORE), and goal attainment was assessed based on the European League Against Rheumatism guidelines. Actual CVD risk and perceived risk were compared with cross-tabulation. Chi-square tests were used to evaluate differences in cardiovascular risk factors by perceived risk. Levels of goal attainment were presented in percentages.Among patients with RA, 13.9% were identified as being at high risk for CVD, whereas 39.9% were at moderate risk, and 46.2% were at low risk. The majority of those at high risk (96.6%) underestimated their risk for CVD. The use of antihypertensive or lipid-lowering medications and having a parental history of CVD significantly increased the likelihood that subjects with RA would perceive themselves as being at high risk for CVD. Diabetes, smoking, physical inactivity, and obesity did not affect perceived risk. A substantial proportion of the subjects with RA did not meet the prevention guideline goals.Patients with RA who are at increased risk of developing CVD must be managed as soon as possible to attain the guideline goals and, accordingly, lower their risk of future CVD.

  7. Australian community pharmacists' awareness and practice in supporting secondary prevention of cardiovascular disease.

    PubMed

    Puspitasari, Hanni Prihhastuti; Aslani, Parisa; Krass, Ines

    2013-12-01

    Pharmacists are well placed to identify, prevent and resolve medicine related problems as well as monitor the effectiveness of treatments in cardiovascular disease (CVD). Pharmacists' interventions in CVD secondary prevention have been shown to improve outcomes for clients with established CVD. To explore the scope of pharmacists' activities in supporting CVD secondary prevention. Community pharmacies in New South Wales, Australia. Twenty-one in-depth, semi-structured interviews with a range of community pharmacists were conducted. All interviews were audio-recorded and transcribed ad verbatim. Data were analyzed using a 'grounded-theory' approach by applying methods of constant comparison. Community pharmacists' awareness and current practice in supporting secondary prevention of CVD. Four key themes identified included 'awareness', 'patient counselling', 'patient monitoring', and 'perceptions of the role of pharmacists in CVD secondary prevention'. The pharmacists demonstrated a moderate understanding of CVD secondary prevention. There was considerable variability in the scope of practice among the participants, ranging from counselling only about medicines to providing continuity of care. A minority of pharmacists who had negative beliefs about their roles in CVD secondary prevention offered limited support to their clients. The majority of pharmacists, however, believed that they have an important role to play in supporting clients with established CVD. Community pharmacists in Australia make a contribution to the care of clients with established CVD despite the gap in their knowledge and understanding of CVD secondary prevention. The scope of practice in CVD secondary prevention ranged from only counselling about medicines to offering continuity of care. The extent of pharmacists' involvement in offering disease management appears to be influenced by their beliefs regarding what is required within their scope of practice.

  8. A Comparative Study of Three Different Chemical Vapor Deposition Techniques of Carbon Nanotube Growth on Diamond Films

    DTIC Science & Technology

    2012-11-01

    microwave plasma-enhanced CVD (MPE-CVD) with presputtered metal catalyst, and floating catalyst thermal CVD (FCT-CVD) with xylene and ferrocene liquid...processes with nickel and iron catalysts, respectively. For the FCT-CVD approach, ferrocene is used as an iron source to promoteCNT growth. Based on...furnace is ramped up to the growth temperature of 750∘C. Ferrocene was dissolved into a xylene solvent in a 0.008 : 1molar volume ratio.The xylene

  9. Acarbose Treatment and the Risk of Cardiovascular Disease in Type 2 Diabetic Patients: A Nationwide Seven-Year Follow-Up Study

    PubMed Central

    Chen, Jui-Ming; Chang, Cheng-Wei; Lin, Ying-Chieh; Horng, Jorng-Tzong; Sheu, Wayne H.-H.

    2014-01-01

    Objective. To investigate the potential benefits of acarbose treatment on cardiovascular disease (CVD) in patients with type 2 diabetes by using nationwide insurance claim dataset. Research Design and Methods. Among 644,792 newly diagnosed type 2 diabetic patients without preexisting CVD in a nationwide cohort study, 109,139 (16.9%) who had received acarbose treatment were analyzed for CVD risk. Those with CVD followed by acarbose therapy were also subjected to analysis. Result. During 7 years of follow-up, 5,081 patients (4.7%) developed CVD. The crude hazard ratio (HR) and adjusted HR were 0.66 and 0.99, respectively. The adjusted HR of CVD was 1.19, 0.70, and 0.38 when the duration of acarbose use was <12 months, 12–24 months, and >24 months, respectively. Adjusted HR was 1.14, 0.64, and 0.41 with acarbose cumulative doses <54,750 mg, 54,751 to 109,500 mg, and >109,500 mg, respectively. Conclusion. In patients with type 2 diabetes without preexisting CVD, treatment with acarbose showed a transient increase in incidence of CVD in the initial 12 months followed by significant reductions of CVD in prolonged acarbose users. After the first CVD events, continuous use of acarbose revealed neutral effect within the first 12 months. The underlying mechanisms require further investigations. PMID:25197673

  10. Anxiety sensitivity in smokers with indicators of cardiovascular disease.

    PubMed

    Farris, Samantha G; Abrantes, Ana M

    2017-09-01

    There is growing recognition of the importance of understanding the nature of the associations between anxiety and cardiovascular disease (CVD), although limited research has examined mechanisms that may explain the anxiety-CVD link. Anxiety sensitivity (fear of anxiety-relevant somatic sensations) is a cognitive-affective risk factor implicated in the development of anxiety psychopathology and various behavioral risk factors for CVD, although has not been examined among individuals with CVD. Adult daily smokers (n = 619; 50.9% female; M age  = 44.0, SD = 13.67) completed an online survey that included the Anxiety Sensitivity Index-3 (ASI-3) and the Patient Health Questionnaire (PHQ). The presence of CVD was assessed via the presence of ≥1 of the following: heart attack, heart murmur, positive stress test, heart valve abnormality, angina, and heart failure. Smokers with CVD indicators (n = 66, 10.7%) had significantly higher scores on the ASI-3 (M = 33.5, SD = 22.15), relative to smokers without CVD (M = 22.0, SD = 17.92; Cohen's d = .57). Those with CVD were significantly more likely to have moderate or high anxiety sensitivity (66.7%) relative to those without CVD (49.4%). Physical and social concerns about the meaning of somatic sensations were common among smokers with CVD.

  11. The MUK five protocol: a phase II randomised, controlled, parallel group, multi-centre trial of carfilzomib, cyclophosphamide and dexamethasone (CCD) vs. cyclophosphamide, bortezomib (Velcade) and dexamethasone (CVD) for first relapse and primary refractory multiple myeloma.

    PubMed

    Brown, Sarah; Hinsley, Samantha; Ballesteros, Mónica; Bourne, Sue; McGarry, Paul; Sherratt, Debbie; Flanagan, Louise; Gregory, Walter; Cavenagh, Jamie; Owen, Roger; Williams, Cathy; Kaiser, Martin; Low, Eric; Yong, Kwee

    2016-01-01

    Multiple myeloma is a plasma cell tumour with an annual incidence in the UK of approximately 40-50 per million i.e. about 4500 new cases per annum. The triple combination cyclophosphamide, bortezomib (Velcade®) and dexamethasone (CVD) is an effective regimen at relapse and has emerged in recent years as the standard therapy at first relapse in the UK. Carfilzomib has good activity as a single agent in the relapsed setting, and it is expected that efficacy will be improved when used in combination with dexamethasone and cyclophosphamide. MUK Five is a phase II open label, randomised, controlled, parallel group, multi-centre trial that will compare the activity of carfilzomib, cyclophosphamide and dexamethasone (CCD) with that of CVD, given over an equivalent treatment period (24 weeks), in participants with multiple myeloma at first relapse, or refractory to no more than 1 line of treatment. In addition, the study also aims to assess the utility of a maintenance schedule of carfilzomib in these participants. The primary objective of the trial is to assess whether CCD provides non-inferior activity in terms of ≥ VGPR rates at 24 weeks, and whether the addition of maintenance treatment with carfilzomib to CCD provides superior activity in terms of progression-free survival, as compared to CCD with no maintenance. Secondary objectives include comparing toxicity profiles, further summarizing and comparing the activity of the different treatment arms and analysis of the effect of each treatment arm on minimal residual disease status. The development of carfilzomib offers the opportunity to further explore the anti-tumour efficacy of proteasome inhibition and, based on the available evidence, it is important and timely to obtain data on the activity, toxicity and tolerability of this drug. In contrast to ongoing phase III trials, this phase II trial has a unique subset of participants diagnosed with multiple myeloma at first relapse or refractory to no more than

  12. Cardiovascular Disease is Associated with COPD Severity and Reduced Functional Status and Quality of Life

    PubMed Central

    Black-Shinn, Jennifer L.; Kinney, Gregory L.; Wise, Anastasia L.; Regan, Elizabeth A.; Make, Barry; Krantz, Mori J.; Barr, R. Graham; Murphy, James R.; Lynch, David; Silverman, Edwin K.; Crapo, James D.; Hokanson, John E.

    2015-01-01

    Introduction Smoking is a major risk factor for both cardiovascular disease (CVD) and chronic obstructive pulmonary disease (COPD). More individuals with COPD die from CVD than respiratory causes and the risk of developing CVD appears to be independent of smoking burden. Although CVD is a common comorbid condition within COPD, the nature of its relationships to COPD affection status and severity, and functional status is not well understood. Methods The first 2,500 members of the COPDGene cohort were evaluated. Subjects were current and former smokers with a minimum 10 pack year history of cigarette smoking. COPD was defined by spirometry as an FEV1/FVC < lower limit of normal (LLN) with further identification of severity by FEV1 percent of predicted (GOLD stages 2, 3, and 4) for the main analysis. The presence of physician-diagnosed self-reported CVD was determined from a medical history questionnaire administered by a trained staff member. Results A total of 384 (15%) had pre-existing CVD. Self-reported CVD was independently related to COPD (Odds Ratio=1.61, 95% CI=1.18–2.20, p=0.01) after adjustment for covariates with CHF having the greatest association with COPD. Within subjects with COPD, pre-existing self-reported CVD placed subjects at greater risk of hospitalization due to exacerbation, higher BODE index, and greater St. George’s questionnaire score. The presence of self-reported CVD was associated with a shorter six-minute walk distance in those with COPD (p<0.05). Conclusions Self-reported CVD was independently related to COPD with presence of both self-reported CVD and COPD associated with a markedly reduced functional status and reduced quality of life. Identification of CVD in those with COPD is an important consideration in determining functional status. PMID:24831864

  13. Challenges of developing a cardiovascular risk calculator for patients with rheumatoid arthritis.

    PubMed

    Crowson, Cynthia S; Rollefstad, Silvia; Kitas, George D; van Riel, Piet L C M; Gabriel, Sherine E; Semb, Anne Grete

    2017-01-01

    Cardiovascular disease (CVD) risk calculators designed for use in the general population do not accurately predict the risk of CVD among patients with rheumatoid arthritis (RA), who are at increased risk of CVD. The process of developing risk prediction models involves numerous issues. Our goal was to develop a CVD risk calculator for patients with RA. Thirteen cohorts of patients with RA originating from 10 different countries (UK, Norway, Netherlands, USA, Sweden, Greece, South Africa, Spain, Canada and Mexico) were combined. CVD risk factors and RA characteristics at baseline, in addition to information on CVD outcomes were collected. Cox models were used to develop a CVD risk calculator, considering traditional CVD risk factors and RA characteristics. Model performance was assessed using measures of discrimination and calibration with 10-fold cross-validation. A total of 5638 RA patients without prior CVD were included (mean age: 55 [SD: 14] years, 76% female). During a mean follow-up of 5.8 years (30139 person years), 389 patients developed a CVD event. Event rates varied between cohorts, necessitating inclusion of high and low risk strata in the models. The multivariable analyses revealed 2 risk prediction models including either a disease activity score including a 28 joint count and erythrocyte sedimentation rate (DAS28ESR) or a health assessment questionnaire (HAQ) along with age, sex, presence of hypertension, current smoking and ratio of total cholesterol to high-density lipoprotein cholesterol. Unfortunately, performance of these models was similar to general population CVD risk calculators. Efforts to develop a specific CVD risk calculator for patients with RA yielded 2 potential models including RA disease characteristics, but neither demonstrated improved performance compared to risk calculators designed for use in the general population. Challenges encountered and lessons learned are discussed in detail.

  14. Effect of gender on awareness of cardiovascular risk factors, preventive action taken, and barriers to cardiovascular health in a group of Austrian subjects.

    PubMed

    Haidinger, Teresa; Zweimüller, Martin; Stütz, Lena; Demir, Dondue; Kaider, Alexandra; Strametz-Juranek, Jeanette

    2012-04-01

    The incidence of cardiovascular disease (CVD) is increasing in industrialized countries. Preventive action is an important factor in minimizing CVD-associated morbidity and mortality. However, it is not known whether gender differences affect CVD or risk factor awareness influencing self-assessment of personal risk and preventive action. This study was performed to assess individual CVD and risk factor awareness, preventive action taken, and barriers to cardiovascular health. The study included 573 women and 336 men, randomly chosen to complete an anonymous questionnaire to assess individual CVD and risk factor awareness, preventive action taken, and barriers to cardiovascular health. The data were analyzed using SAS software. Cardiovascular disease was identified in 75% of patients, in both sexes, as the leading cause of death; however, both groups showed significant lack of knowledge about CVD risk factors. Type 2 diabetes was identified correctly in only 27.5%. Preventive action was linked more often to family members in 66.5% of women and 62.8% of men. The primary barrier to cardiovascular health in adults was incorrect assessment of personal CVD risk. More than half of female respondents (56.4%) and male respondents (52.7%) underestimated their risk of CVD. Knowledge about risk factors for CVD needs to be improved in members of both sexes. Because women, in particular, have difficulty in correctly assessing their personal CVD risk, future education programs are warranted to inform both women and men about CVD and its risk factors, thereby helping them to correctly assess their individual risk. However, greater effort is needed to inform men, compared with women, about the various ways in which to prevent CVD and to motivate them to take preventive action. Copyright © 2012 Elsevier HS Journals, Inc. All rights reserved.

  15. Rheumatoid Arthritis, Anti-CCP Positivity, and Cardiovascular Disease Risk in the Women’s Health Initiative

    PubMed Central

    Mackey, Rachel H.; Kuller, Lewis H.; Deane, Kevin D.; Walitt, Brian T.; Chang, Yuefang F.; Holers, V. Michael; Robinson, William H.; Tracy, Russell P.; Hlatky, Mark A.; Eaton, Charles; Liu, Simin; Freiberg, Matthew S.; Talabi, Mehret Birru; Schelbert, Erik B.; Moreland, Larry W.

    2015-01-01

    Objective This report evaluates incidence of cardiovascular disease (CVD) morbidity and mortality over 10 years among the >160,000 postmenopausal women in the Women’s Health Initiative (WHI) in relation to self-reported RA, disease modifying anti-rheumatic drugs (DMARD) use, anti-CCP+, RF+, CVD risk factors, joint pain, and inflammation (white blood cell (WBC) count and IL-6.) Methods Anti-CCP and RF were measured on a sample (n=9,988) of WHI participants with self-reported RA. RA was classified as self-reported RA plus anti-CCP+ positivity and/or use of DMARDs. Self-reported RA that was both anti-CCP− and DMARD− was classified as “unverified RA.” Results Age-adjusted rates of coronary heart disease (CHD), stroke, CVD, fatal CVD and total mortality were higher for women with RA vs. no RA, with multivariable-adjusted HR(95%CI) of 1.46(1.17, 1.83) for CHD, and 2.55(1.86, 3.51) for fatal CVD. Within RA, anti-CCP+ and RF+ were not significantly associated with higher risk of any outcomes, despite slightly higher risk of fatal CVD and death for anti-CCP+ vs. anti-CCP− RA. Joint pain severity and CVD risk factors were strongly associated with CVD risk, even for women with no RA. CVD incidence was increased for RA vs. no RA at almost all risk factor levels, except low levels of joint pain or inflammation. Within RA, inflammation was more strongly associated with fatal CVD and total mortality than CHD or CVD. Conclusion Among postmenopausal women, RA was associated with 1.5-2.5 higher CVD risk, strongly associated with CV risk factors, joint pain severity, and inflammation, but similar for anti-CCP+ and RF+. Clinical Trial Registration clinicaltrials.gov identifier: NCT00000611 PMID:25988241

  16. Racial differences in risks for first cardiovascular events and noncardiovascular death: the Atherosclerosis Risk in Communities study, the Cardiovascular Health Study, and the Multi-Ethnic Study of Atherosclerosis.

    PubMed

    Feinstein, Matthew; Ning, Hongyan; Kang, Joseph; Bertoni, Alain; Carnethon, Mercedes; Lloyd-Jones, Donald M

    2012-07-03

    No studies have compared first cardiovascular disease (CVD) events and non-CVD death between races in a competing risks framework, which examines risks for numerous events simultaneously. We used competing Cox models to estimate hazards for first CVD events and non-CVD death within and between races in 3 multicenter, National Heart, Lung, and Blood Institute-sponsored cohorts. Of 14 569 Atherosclerosis Risk in Communities (ARIC) study participants aged 45 to 64 years with mean follow-up of 10.5 years, 11.6% had CVD and 5.0% had non-CVD death as first events; among 4237 Cardiovascular Health Study (CHS) study participants aged 65 to 84 years and followed for 8.5 years, these figures were 43.2% and 15.7%, respectively. Middle-aged blacks were significantly more likely than whites to experience any CVD as a first event; this disparity disappeared by older adulthood and after adjustment for CVD risk factors. The pattern of results was similar for Multi-Ethnic Study of Atherosclerosis (MESA) participants. Traditional Cox and competing risks models yielded different results for coronary heart disease risk. Black men appeared somewhat more likely than white men to experience coronary heart disease with use of a standard Cox model (hazard ratio 1.06; 95% CI 0.90, 1.26), whereas they appeared less likely than white men to have a first coronary heart disease event with use of a competing risks model (hazard ratio, 0.77; 95% CI, 0.60, 1.00). CVD affects blacks at an earlier age than whites; this may be attributable in part to elevated CVD risk factor levels among blacks. Racial disparities in first CVD incidence disappear by older adulthood. Competing risks analyses may yield somewhat different results than traditional Cox models and provide a complementary approach to examining risks for first CVD events.

  17. Einsatz molekularer Methoden für Starterkulturen

    NASA Astrophysics Data System (ADS)

    Ehrmann, Matthias A.; Pavlovic, Melanie

    Unter Starterkulturen versteht man Mikroorganismen (Bakterien, Hefen, Pilze), die pflanzlichen bzw. tierischen Rohstoffen zur gezielten Veränderung ihrer chemischen Zusammensetzung zugesetzt werden. Sie dienen im Wesentlichen der Aromabildung, der Strukturveränderung und der Konservierung der Lebensmittel und werden aufgrund spezieller, funktioneller Eigenschaften selektiert. Die Zugabe von Starterkulturen erfolgt in der Regel in relativ hohen Keimzahlen in Form von Rein- oder Mischkulturen. Die zum Einsatz kommenden Mikroorganismen sind ebenso zahlreich wie die daraus resultierenden Produkte und reichen von der Fermentation von Milchprodukten, Fleisch und Gemüse durch Milchsäurebakterien über die Essigsäureherstellung bis hin zum Einsatz von Hefen in der Brau- und Weinindustrie. Hieraus ergibt sich auch eine zunehmende Bedeutung schneller und zuverlässiger Methoden zur taxonomischen Identifizierung, aber auch zur Charakterisierung des genetischen Potenzials der jeweiligen Starterkulturen.

  18. Cardiovascular risk-factor knowledge and risk perception among HIV-infected adults.

    PubMed

    Cioe, Patricia A; Crawford, Sybil L; Stein, Michael D

    2014-01-01

    Cardiovascular disease (CVD) has emerged as a major cause of morbidity and mortality in HIV-infected adults. Research in noninfected populations has suggested that knowledge of CVD risk factors significantly influences perceptions of risk. This cross-sectional study describes CVD risk factor knowledge and risk perception in HIV-infected adults. We recruited 130 HIV-infected adults (mean age = 48 years, 62% male, 56% current smokers, mean years since HIV diagnosis, 14.7). The mean CVD risk factor knowledge score was fairly high. However, controlling for age, CVD risk factor knowledge was not predictive of perceived risk [F(1, 117) = 0.13, p > .05]. Estimated risk and perceived risk were weakly but significantly correlated; r (126) = .24, p = .01. HIV-infected adults are at increased risk for CVD. Despite having adequate risk-factor knowledge, CVD risk perception was inaccurate. Improving risk perception and developing CVD risk reduction interventions for this population are imperative. Copyright © 2014 Association of Nurses in AIDS Care. Published by Elsevier Inc. All rights reserved.

  19. Surface Design and Engineering Toward Wear-Resistant, Self-Lubricant Diamond Films and Coatings. Chapter 10

    NASA Technical Reports Server (NTRS)

    Miyoshi, Kazuhisa

    1999-01-01

    This chapter describes three studies on the surface design, surface engineering, and tribology of chemical-vapor-deposited (CVD) diamond films and coatings toward wear-resistant, self-lubricating diamond films and coatings. Friction mechanisms and solid lubrication mechanisms of CVD diamond are stated. Effects of an amorphous hydrogenated carbon on CVD diamond, an amorphous, nondiamond carbon surface layer formed on CVD diamond by carbon and nitrogen ion implantation, and a materials combination of cubic boron nitride and CVD diamond on the adhesion, friction, and wear behaviors of CVD diamond in ultrahigh vacuum are described. How surface modification and the selected materials couple improved the tribological functionality of coatings, giving low coefficient of friction and good wear resistance, is explained.

  20. The Burden of Cardiovascular Diseases Among US States, 1990-2016.

    PubMed

    Roth, Gregory A; Johnson, Catherine O; Abate, Kalkidan Hassen; Abd-Allah, Foad; Ahmed, Muktar; Alam, Khurshid; Alam, Tahiya; Alvis-Guzman, Nelson; Ansari, Hossein; Ärnlöv, Johan; Atey, Tesfay Mehari; Awasthi, Ashish; Awoke, Tadesse; Barac, Aleksandra; Bärnighausen, Till; Bedi, Neeraj; Bennett, Derrick; Bensenor, Isabela; Biadgilign, Sibhatu; Castañeda-Orjuela, Carlos; Catalá-López, Ferrán; Davletov, Kairat; Dharmaratne, Samath; Ding, Eric L; Dubey, Manisha; Faraon, Emerito Jose Aquino; Farid, Talha; Farvid, Maryam S; Feigin, Valery; Fernandes, João; Frostad, Joseph; Gebru, Alemseged; Geleijnse, Johanna M; Gona, Philimon Nyakauru; Griswold, Max; Hailu, Gessessew Bugssa; Hankey, Graeme J; Hassen, Hamid Yimam; Havmoeller, Rasmus; Hay, Simon; Heckbert, Susan R; Irvine, Caleb Mackay Salpeter; James, Spencer Lewis; Jara, Dube; Kasaeian, Amir; Khan, Abdur Rahman; Khera, Sahil; Khoja, Abdullah T; Khubchandani, Jagdish; Kim, Daniel; Kolte, Dhaval; Lal, Dharmesh; Larsson, Anders; Linn, Shai; Lotufo, Paulo A; Magdy Abd El Razek, Hassan; Mazidi, Mohsen; Meier, Toni; Mendoza, Walter; Mensah, George A; Meretoja, Atte; Mezgebe, Haftay Berhane; Mirrakhimov, Erkin; Mohammed, Shafiu; Moran, Andrew Edward; Nguyen, Grant; Nguyen, Minh; Ong, Kanyin Liane; Owolabi, Mayowa; Pletcher, Martin; Pourmalek, Farshad; Purcell, Caroline A; Qorbani, Mostafa; Rahman, Mahfuzar; Rai, Rajesh Kumar; Ram, Usha; Reitsma, Marissa Bettay; Renzaho, Andre M N; Rios-Blancas, Maria Jesus; Safiri, Saeid; Salomon, Joshua A; Sartorius, Benn; Sepanlou, Sadaf Ghajarieh; Shaikh, Masood Ali; Silva, Diego; Stranges, Saverio; Tabarés-Seisdedos, Rafael; Tadele Atnafu, Niguse; Thakur, J S; Topor-Madry, Roman; Truelsen, Thomas; Tuzcu, E Murat; Tyrovolas, Stefanos; Ukwaja, Kingsley Nnanna; Vasankari, Tommi; Vlassov, Vasiliy; Vollset, Stein Emil; Wakayo, Tolassa; Weintraub, Robert; Wolfe, Charles; Workicho, Abdulhalik; Xu, Gelin; Yadgir, Simon; Yano, Yuichiro; Yip, Paul; Yonemoto, Naohiro; Younis, Mustafa; Yu, Chuanhua; Zaidi, Zoubida; Zaki, Maysaa El Sayed; Zipkin, Ben; Afshin, Ashkan; Gakidou, Emmanuela; Lim, Stephen S; Mokdad, Ali H; Naghavi, Mohsen; Vos, Theo; Murray, Christopher J L

    2018-04-11

    Cardiovascular disease (CVD) is the leading cause of death in the United States, but regional variation within the United States is large. Comparable and consistent state-level measures of total CVD burden and risk factors have not been produced previously. To quantify and describe levels and trends of lost health due to CVD within the United States from 1990 to 2016 as well as risk factors driving these changes. Using the Global Burden of Disease methodology, cardiovascular disease mortality, nonfatal health outcomes, and associated risk factors were analyzed by age group, sex, and year from 1990 to 2016 for all residents in the United States using standardized approaches for data processing and statistical modeling. Burden of disease was estimated for 10 groupings of CVD, and comparative risk analysis was performed. Data were analyzed from August 2016 to July 2017. Residing in the United States. Cardiovascular disease disability-adjusted life-years (DALYs). Between 1990 and 2016, age-standardized CVD DALYs for all states decreased. Several states had large rises in their relative rank ordering for total CVD DALYs among states, including Arkansas, Oklahoma, Alabama, Kentucky, Missouri, Indiana, Kansas, Alaska, and Iowa. The rate of decline varied widely across states, and CVD burden increased for a small number of states in the most recent years. Cardiovascular disease DALYs remained twice as large among men compared with women. Ischemic heart disease was the leading cause of CVD DALYs in all states, but the second most common varied by state. Trends were driven by 12 groups of risk factors, with the largest attributable CVD burden due to dietary risk exposures followed by high systolic blood pressure, high body mass index, high total cholesterol level, high fasting plasma glucose level, tobacco smoking, and low levels of physical activity. Increases in risk-deleted CVD DALY rates between 2006 and 2016 in 16 states suggest additional unmeasured risks beyond these

  1. Exercise and cardiovascular outcomes by hypertensive status: NHANES I epidemiological follow-up study, 1971-1992.

    PubMed

    Fang, Jing; Wylie-Rosett, Judith; Alderman, Michael H

    2005-06-01

    A favorable effect of exercise on cardiovascular longevity has been repeatedly demonstrated in the general population. The association of exercise and cardiovascular disease (CVD) outcome among persons with different blood pressure (BP) status is less well known. We examined the epidemiologic follow-up of the First National Health and Nutrition Examination Survey (NHANES I) (1971-1992). Of 14,407 participants, 9791 subjects aged 25 to 74 years met inclusion criteria. All cause, CVD, and non-CVD mortality rates, as well as CVD incidence rates were determined. The associations of levels of exercise and outcomes by BP status were examined. Age- and gender-adjusted rates, as well as Cox proportional hazard models were determined. During 17 years of follow-up, there were 3069 deaths, 1465 of which were CVD. In addition, 2808 subjects had incident CVD events. Overall, CVD incidence and mortality rates increased as BP rose. The association of exercise with CVD events differed by BP status (normal, prehypertension, and hypertension). Age- and gender-adjusted CVD mortality rate per 1000 person-years for least, moderate, and most exercise were 5.0, 3.6, and 2.4 among normotensive subjects (P > .05), 6.3, 4.7, and 5.2 among prehypertensive subjects (P > .05), and 11.8, 9.8, and 8.7 among hypertensive subjects (P < .01), respectively. In fact, exercise was a significant independent predictor of reduced CVD event only among hypertensive subjects, after adjusting for other CVD risk factors. Among prehypertensive and normotensive subjects, where events were fewer, those who exercise more vigorously also had lower mortality, but these differences did not reach statistical significance. This study, consistent with previous observational data, demonstrates that increased exercise is associated with decreased CVD event. Interestingly, this effect is most robust among hypertensive subjects, whereas for prehypertensive and normotensive subjects, a significant benefit of exercise on CVD

  2. Prediction of cardiovascular disease risk among low-income urban dwellers in metropolitan Kuala Lumpur, Malaysia.

    PubMed

    Su, Tin Tin; Amiri, Mohammadreza; Mohd Hairi, Farizah; Thangiah, Nithiah; Bulgiba, Awang; Majid, Hazreen Abdul

    2015-01-01

    We aimed to predict the ten-year cardiovascular disease (CVD) risk among low-income urban dwellers of metropolitan Malaysia. Participants were selected from a cross-sectional survey conducted in Kuala Lumpur. To assess the 10-year CVD risk, we employed the Framingham risk scoring (FRS) models. Significant determinants of the ten-year CVD risk were identified using General Linear Model (GLM). Altogether 882 adults (≥30 years old with no CVD history) were randomly selected. The classic FRS model (figures in parentheses are from the modified model) revealed that 20.5% (21.8%) and 38.46% (38.9%) of respondents were at high and moderate risk of CVD. The GLM models identified the importance of education, occupation, and marital status in predicting the future CVD risk. Our study indicated that one out of five low-income urban dwellers has high chance of having CVD within ten years. Health care expenditure, other illness related costs and loss of productivity due to CVD would worsen the current situation of low-income urban population. As such, the public health professionals and policy makers should establish substantial effort to formulate the public health policy and community-based intervention to minimize the upcoming possible high mortality and morbidity due to CVD among the low-income urban dwellers.

  3. Obesity-related inflammation & cardiovascular disease: efficacy of a yoga-based lifestyle intervention.

    PubMed

    Sarvottam, Kumar; Yadav, Raj Kumar

    2014-06-01

    Obesity is a global health burden and its prevalence is increasing substantially due to changing lifestyle. Chronic adiposity is associated with metabolic imbalance leading to dyslipidaemia, diabetes, hypertension and cardiovascular diseases (CVD). Adipose tissue acts as an endocrine organ releasing several adipocytokines, and is associated with increased levels of tissue and circulating inflammatory biomolecules causing vascular inflammation and atherogenesis. Further, inflammation is also associated independently with obesity as well as CVD. Keeping this in view, it is possible that a reduction in weight may lead to a decrease in inflammation, resulting in CVD risk reduction, and better management of patients with CVD. Lifestyle intervention has been endorsed by several health authorities in prevention and management of chronic diseases. A yoga-based lifestyle intervention appears to be a promising option in reducing the risk for CVD as well as management of patients with CVD as it is simple to follow and cost-effective with high compliance. The efficacy of such lifestyle intervention programmes is multifaceted, and is achieved via reduction in weight, obesity-related inflammation and stress, thereby culminating into risk reduction towards several chronic diseases including CVD. In this review, the association between obesity-related inflammation and CVD, and the role of yoga-based lifestyle intervention in prevention and management of CVD are discussed.

  4. Differences in the Cardiometabolic Control in Type 2 Diabetes according to Gender and the Presence of Cardiovascular Disease: Results from the eControl Study

    PubMed Central

    Mata-Cases, Manel; Vinagre, Irene; Patitucci, Flor; Hermosilla, Eduard; Casellas, Aina; Bolivar, Bonaventura; Mauricio, Dídac

    2014-01-01

    The objective of this cross-sectional study was to assess differences in the control and treatment of modifiable cardiovascular risk factors (CVRF: HbA1c, blood pressure [BP], LDL-cholesterol, body mass index, and smoking habit) according to gender and the presence of cardiovascular disease (CVD) in patients with type 2 diabetes mellitus (T2DM) in Catalonia, Spain. The study included available data from electronic medical records for a total of 286,791 patients. After controlling for sex, age, diabetes duration, and treatment received, both men and women with prior CVD had worse cardiometabolic control than patients without previous CVD; women with prior CVD had worse overall control of CVRFs than men except for smoking; and women without prior CVD were only better than men at controlling smoking and BP, with no significant differences in glycemic control. Finally, although the proportion of women treated with lipid-lowering medications was similar to (with prior CVD) or even higher (without CVD) than men, LDL-cholesterol levels were remarkably uncontrolled in both women with and women without CVD. The results stress the need to implement measures to better prevent and treat CVRF in the subgroup of diabetic women, specifically with more intensive statin treatment in those with CVD. PMID:25328520

  5. Genetic variation associated with cardiovascular risk in autoimmune diseases

    PubMed Central

    Perrotti, Pedro P.; Aterido, Adrià; Fernández-Nebro, Antonio; Cañete, Juan D.; Ferrándiz, Carlos; Tornero, Jesús; Gisbert, Javier P.; Domènech, Eugeni; Fernández-Gutiérrez, Benjamín; Gomollón, Fernando; García-Planella, Esther; Fernández, Emilia; Sanmartí, Raimon; Gratacós, Jordi; Martínez-Taboada, Víctor Manuel; Rodríguez-Rodríguez, Luís; Palau, Núria; Tortosa, Raül; Corbeto, Mireia L.; Lasanta, María L.; Marsal, Sara; Julià, Antonio

    2017-01-01

    Autoimmune diseases have a higher prevalence of cardiovascular events compared to the general population. The objective of this study was to investigate the genetic basis of cardiovascular disease (CVD) risk in autoimmunity. We analyzed genome-wide genotyping data from 6,485 patients from six autoimmune diseases that are associated with a high socio-economic impact. First, for each disease, we tested the association of established CVD risk loci. Second, we analyzed the association of autoimmune disease susceptibility loci with CVD. Finally, to identify genetic patterns associated with CVD risk, we applied the cross-phenotype meta-analysis approach (CPMA) on the genome-wide data. A total of 17 established CVD risk loci were significantly associated with CVD in the autoimmune patient cohorts. From these, four loci were found to have significantly different genetic effects across autoimmune diseases. Six autoimmune susceptibility loci were also found to be associated with CVD risk. Genome-wide CPMA analysis identified 10 genetic clusters strongly associated with CVD risk across all autoimmune diseases. Two of these clusters are highly enriched in pathways previously associated with autoimmune disease etiology (TNFα and IFNγ cytokine pathways). The results of this study support the presence of specific genetic variation associated with the increase of CVD risk observed in autoimmunity. PMID:28982122

  6. Comparison of the quality of single-crystal diamonds grown on two types of seed substrates by MPCVD

    NASA Astrophysics Data System (ADS)

    Zhao, Yun; Guo, Yanzhao; Lin, Liangzhen; Zheng, Yuting; Hei, Lifu; Liu, Jinlong; Wei, Junjun; Chen, Liangxian; Li, Chengming

    2018-06-01

    Microwave plasma chemical vapor deposition (MPCVD) was used to grow single-crystal diamonds on two types of single-crystal diamond seed substrates prepared by high-pressure, high-temperature (HPHT) and chemical vapor deposition (CVD) methods. The quality of diamonds grown on the different seed substrates was compared. Fluorescence characteristics showed that the sectors of the HPHT seed substrates were obviously partitioned. Raman and absorption spectra showed that the CVD seed substrate produced higher-quality crystals with fewer nitrogen impurities. X-ray topography showed that the HPHT seed substrate had obvious growth sector boundaries, inclusions, dislocations, and stacking faults. The polarization characteristics of HPHT seed substrate were obvious, and the stress distribution was not uniform. When etching HPHT and CVD seed substrates using the same parameters, the etching morphology and extent of different growth sectors of the two substrates differed. Although extended defects were inevitably formed at the interface and propagated in the CVD layer, the dislocation density of a 1 mm-thick CVD layer grown on a CVD seed substrate was only half that of a 1 mm-thick CVD layer grown on an HPHT seed substrate. Therefore, the use of CVD seed substrate enabled the growth of a relatively higher-quality CVD single-crystal diamond.

  7. Globalization, Work, and Cardiovascular Disease.

    PubMed

    Schnall, Peter L; Dobson, Marnie; Landsbergis, Paul

    2016-10-01

    Cardiovascular disease (CVD), a global epidemic, is responsible for about 30% of all deaths worldwide. While mortality rates from CVD have been mostly declining in the advanced industrialized nations, CVD risk factors, including hypertension, obesity, and diabetes, have been on the increase everywhere. Researchers investigating the social causes of CVD have produced a robust body of evidence documenting the relationships between the work environment and CVD, including through the mechanisms of psychosocial work stressors. We review the empirical evidence linking work, psychosocial stressors, and CVD. These work stressors can produce chronic biologic arousal and promote unhealthy behaviors and thus, increased CVD risk. We offer a theoretical model that illustrates how economic globalization influences the labor market and work organization in high-income countries, which, in turn, exacerbates job characteristics, such as demands, low job control, effort-reward imbalance, job insecurity, and long work hours. There is also a growing interest in "upstream" factors among work stress researchers, including precarious employment, downsizing/restructuring, privatization, and lean production. We conclude with suggestions for future epidemiologic research on the role of work in the development of CVD, as well as policy recommendations for prevention of work-related CVD. © The Author(s) 2016.

  8. Relationships between the risk of cardiovascular disease in type 2 diabetes patients and both visit-to-visit variability and time-to-effect differences in blood pressure.

    PubMed

    Takao, Toshiko; Kimura, Kumiko; Suka, Machi; Yanagisawa, Hiroyuki; Kikuchi, Masatoshi; Kawazu, Shoji; Matsuyama, Yutaka

    2015-07-01

    To determine whether visit-to-visit blood pressure (BP) variability can predict cardiovascular disease (CVD) incidence in type 2 diabetes patients independently of mean BP, and to analyze the time-to-effect relationship between BP and CVD risk. We retrospectively enrolled 629 type 2 diabetes patients with no history of CVD who first visited our hospital between 1995 and 1996, made at least one hospital visit per year, were followed-up for at least 1 year, and had undergone four or more BP measurements. The patients were followed until June 2012 at the latest. CVD occurred in 66 patients. Variability in systolic or diastolic BP (SBP and DBP, respectively) was a significant predictor of CVD incidence, independent of mean SBP or DBP. CVD incidence was significantly associated with SBP during the preceding 3-5 years, with the highest risk occurring during the preceding 3 years. Visit-to-visit BP variability independently predicts CVD incidence in type 2 diabetes patients. Increased SBP over the preceding 3-5 years indicated a significant CVD risk. To prevent CVD, BP management should focus on stable and well-timed control. In particular, BP stabilization at an early phase and BP control during late phases are important. Copyright © 2015 Elsevier Inc. All rights reserved.

  9. Prediction of Cardiovascular Disease Risk among Low-Income Urban Dwellers in Metropolitan Kuala Lumpur, Malaysia

    PubMed Central

    Su, Tin Tin; Amiri, Mohammadreza; Mohd Hairi, Farizah; Thangiah, Nithiah; Majid, Hazreen Abdul

    2015-01-01

    We aimed to predict the ten-year cardiovascular disease (CVD) risk among low-income urban dwellers of metropolitan Malaysia. Participants were selected from a cross-sectional survey conducted in Kuala Lumpur. To assess the 10-year CVD risk, we employed the Framingham risk scoring (FRS) models. Significant determinants of the ten-year CVD risk were identified using General Linear Model (GLM). Altogether 882 adults (≥30 years old with no CVD history) were randomly selected. The classic FRS model (figures in parentheses are from the modified model) revealed that 20.5% (21.8%) and 38.46% (38.9%) of respondents were at high and moderate risk of CVD. The GLM models identified the importance of education, occupation, and marital status in predicting the future CVD risk. Our study indicated that one out of five low-income urban dwellers has high chance of having CVD within ten years. Health care expenditure, other illness related costs and loss of productivity due to CVD would worsen the current situation of low-income urban population. As such, the public health professionals and policy makers should establish substantial effort to formulate the public health policy and community-based intervention to minimize the upcoming possible high mortality and morbidity due to CVD among the low-income urban dwellers. PMID:25821810

  10. Assessment of medium-term cardiovascular disease risk after Japan’s 2011 Fukushima Daiichi nuclear accident: a retrospective analysis

    PubMed Central

    Nomura, Shuhei; Gilmour, Stuart; Oikawa, Tomoyoshi; Lee, Kiwon; Kiyabu, Grace Y; Shibuya, Kenji

    2017-01-01

    Objective To assess the medium-term indirect impact of the 2011 Fukushima Daiichi nuclear accident on cardiovascular disease (CVD) risks and to identify whether risk factors for CVD changed after the accident. Participants Residents aged 40 years and over participating in annual public health check-ups from 2009 to 2012, administered by Minamisoma city, located about 10 to 40 km from the Fukushima Daiichi nuclear plant. Methods The sex-specific Framingham CVD risk score was considered as the outcome measure and was compared before (2009–2010) and after the accident (2011–2012). A multivariate regression analysis was employed to evaluate risk factors for CVD. Results Data from 563 individuals (60.2% women) aged 40 to 74 years who participated in the check-ups throughout the study period was analysed. After adjusting for covariates, no statistically significant change was identified in the CVD risk score postaccident in both sexes, which may suggest no obvious medium-term health impact of the Fukushima nuclear accident on CVD risk. The risk factors for CVD and their magnitude and direction (positive/negative) did not change after the accident. Conclusions There was no obvious increase in CVD risks in Minamisoma city, which may indicate successful management of health risks associated with CVD in the study sample. PMID:29275343

  11. Cardiovascular Disease in Latin American Patients with Systemic Lupus Erythematosus: A Cross-Sectional Study and a Systematic Review

    PubMed Central

    Amaya-Amaya, Jenny; Caro-Moreno, Julián; Molano-González, Nicolás; Mantilla, Rubén D.; Rojas-Villarraga, Adriana; Anaya, Juan-Manuel

    2013-01-01

    Objective. This study was performed to determine the prevalence of and associated risk factors for cardiovascular disease (CVD) in Latin American (LA) patients with systemic lupus erythematosus (SLE). Methods. First, a cross-sectional analytical study was conducted in 310 Colombian patients with SLE in whom CVD was assessed. Associated factors were examined by multivariate regression analyses. Second, a systematic review of the literature on CVD in SLE in LA was performed. Results. There were 133 (36.5%) Colombian SLE patients with CVD. Dyslipidemia, smoking, coffee consumption, and pleural effusion were positively associated with CVD. An independent effect of coffee consumption and cigarette on CVD was found regardless of gender and duration of disease. In the systematic review, 60 articles fulfilling the eligibility criteria were included. A wide range of CVD prevalence was found (4%–79.5%). Several studies reported ancestry, genetic factors, and polyautoimmunity as novel risk factors for such a condition. Conclusions. A high rate of CVD is observed in LA patients with SLE. Awareness of the observed risk factors should encourage preventive population strategies for CVD in patients with SLE aimed at facilitating the suppression of cigarette smoking and coffee consumption as well as at the tight control of dyslipidemia and other modifiable risk factors. PMID:24294522

  12. Effective aqueous arsenic removal using zero valent iron doped MWCNT synthesized by in situ CVD method using natural α-Fe2O3 as a precursor.

    PubMed

    Alijani, Hassan; Shariatinia, Zahra

    2017-03-01

    This research presents an efficient system for removing aqua's arsenic based on in situ zero valent iron doping onto multiwall carbon nanotube (MWCNT) through MWCNT growth onto the natural α-Fe 2 O 3 surface in chemical vapor deposition (CVD) reactor. The as-synthesized magnetic nanohybrid was characterized by XRD, VSM, FE-SEM and TEM techniques. The result of XRD analysis revealed that MWCNT has been successfully generated on the surface of zero valent iron. Moreover, the material showed good superparamagnetic characteristic to be employed as a magnetic adsorbent. The hematite, nanohybrid and its air oxidized form were used for removing aqueous arsenite and arsenate; however, non oxidized material exhibited greater efficiency for the analytes uptake. Equilibrium times were 60 and 90 min for arsenate and arsenite adsorption using nanohybrid and oxidized sorbent but the equilibrium time was 1320 min using hematite. The adsorption efficiencies of hematite and oxidized sorbent were 18, 74% and 26, 77% for arsenite and arsenate, respectively, at initial concentration of 10 mg L -1 . At this situation, the removal efficiencies were 96 and 98.5% for arsenite and arsenate adsorption using raw nanohybrid. Thermodynamic study was also performed and results indicated that arsenic adsorption onto nanohybrid and oxidized sorbent was spontaneous however hematite followed a nonspontaneous path for the arsenic removal. Copyright © 2016 Elsevier Ltd. All rights reserved.

  13. Risk scoring for the primary prevention of cardiovascular disease.

    PubMed

    Karmali, Kunal N; Persell, Stephen D; Perel, Pablo; Lloyd-Jones, Donald M; Berendsen, Mark A; Huffman, Mark D

    2017-03-14

    The current paradigm for cardiovascular disease (CVD) emphasises absolute risk assessment to guide treatment decisions in primary prevention. Although the derivation and validation of multivariable risk assessment tools, or CVD risk scores, have attracted considerable attention, their effect on clinical outcomes is uncertain. To assess the effects of evaluating and providing CVD risk scores in adults without prevalent CVD on cardiovascular outcomes, risk factor levels, preventive medication prescribing, and health behaviours. We searched the Cochrane Central Register of Controlled Trials (CENTRAL) in the Cochrane Library (2016, Issue 2), MEDLINE Ovid (1946 to March week 1 2016), Embase (embase.com) (1974 to 15 March 2016), and Conference Proceedings Citation Index-Science (CPCI-S) (1990 to 15 March 2016). We imposed no language restrictions. We searched clinical trial registers in March 2016 and handsearched reference lists of primary studies to identify additional reports. We included randomised and quasi-randomised trials comparing the systematic provision of CVD risk scores by a clinician, healthcare professional, or healthcare system compared with usual care (i.e. no systematic provision of CVD risk scores) in adults without CVD. Three review authors independently selected studies, extracted data, and evaluated study quality. We used the Cochrane 'Risk of bias' tool to assess study limitations. The primary outcomes were: CVD events, change in CVD risk factor levels (total cholesterol, systolic blood pressure, and multivariable CVD risk), and adverse events. Secondary outcomes included: lipid-lowering and antihypertensive medication prescribing in higher-risk people. We calculated risk ratios (RR) for dichotomous data and mean differences (MD) or standardised mean differences (SMD) for continuous data using 95% confidence intervals. We used a fixed-effects model when heterogeneity (I²) was at least 50% and a random-effects model for substantial heterogeneity

  14. Association Between Hospitalization for Pneumonia and Subsequent Risk of Cardiovascular Disease

    PubMed Central

    Corrales-Medina, Vicente F.; Alvarez, Karina N.; Weissfeld, Lisa A.; Angus, Derek C.; Chirinos, Julio A.; Chang, Chung-Chou H.; Newman, Anne; Loehr, Laura; Folsom, Aaron R.; Elkind, Mitchell S.; Lyles, Mary F.; Kronmal, Richard A.; Yende, Sachin

    2015-01-01

    IMPORTANCE The risk of cardiovascular disease (CVD) after infection is poorly understood. OBJECTIVE To determine whether hospitalization for pneumonia is associated with an increased short-term and long-term risk of CVD. DESIGN, SETTINGS, AND PARTICIPANTS We examined 2 community-based cohorts: the Cardiovascular Health Study (CHS, n = 5888; enrollment age, ≥65 years; enrollment period, 1989–1994) and the Atherosclerosis Risk in Communities study (ARIC, n = 15 792; enrollment age, 45-64 years; enrollment period, 1987–1989). Participants were followed up through December 31, 2010. We matched each participant hospitalized with pneumonia to 2 controls. Pneumonia cases and controls were followed for occurrence of CVD over 10 years after matching. We estimated hazard ratios (HRs) for CVD at different time intervals, adjusting for demographics, CVD risk factors, subclinical CVD, comorbidities, and functional status. EXPOSURES Hospitalization for pneumonia. MAIN OUTCOMES AND MEASURES Incident CVD (myocardial infarction, stroke, and fatal coronary heart disease). RESULTS Of 591 pneumonia cases in CHS, 206 had CVD events over 10 years after pneumonia hospitalization. Compared with controls, CVD risk among pneumonia cases was highest during the first year after hospitalization and remained significantly higher than among controls through 10 years. In ARIC, of 680 pneumonia cases, 112 had CVD events over 10 years after hospitalization. After the second year, CVD risk among pneumonia cases was not significantly higher than among controls. Pneumonia Cases Controls HR (95% CI) CHS No. of participants 591 1182 CVD events  0-30 d 54 6 4.07 (2.86-5.27)  31-90 d 11 9 2.94 (2.18-3.70)  91 d-1 y 22 55 2.10 (1.59-2.60)  9-10 y 4 12 1.86 (1.18-2.55) ARIC No. of participants 680 1360 CVD events  0-30 d 4 3 2.38 (1.12-3.63)  31-90 d 4 0 2.40 (1.23-3.47)  91 d-1 y 11 8 2.19 (1.20-3.19)  1-2 y 8 7 1.88 (1.10-2.66) CONCLUSIONS AND RELEVANCE Hospitalization for pneumonia

  15. "Ikigai", Subjective Wellbeing, as a Modifier of the Parity-Cardiovascular Mortality Association - The Japan Collaborative Cohort Study.

    PubMed

    Yasukawa, Sumiyo; Eguchi, Eri; Ogino, Keiki; Tamakoshi, Akiko; Iso, Hiroyasu

    2018-04-25

    Nulliparity is associated with an excess risk of cardiovascular disease (CVD). "Ikigai", subjective wellbeing in Japan, is associated with reduced risk of CVD. The impact of ikigai on the association between parity and the risk of CVD, however, has not been reported.Methods and Results:A total of 39,870 Japanese women aged 40-79 years without a history of CVD, cancer or insufficient information at baseline in 1988-1990, were enrolled and followed until the end of 2009. They were categorized into 7 groups according to parity number 0-≥6. Using Cox regression hazard modeling, the associations between parity and mortality from stroke, coronary artery disease, and total CVD were investigated. During the follow-up period, 2,121 total CVD deaths were documented. No association was observed between parity and stroke and CVD mortality in women with ikigai, but there was an association in those without ikigai. The multivariable hazard ratios of stroke and total CVD mortality for nulliparous women without ikigai vs. those with 1 child were 1.87 (95% CI: 1.15-3.05) and 1.46 (95% CI: 1.07-2.01), respectively, and that for stroke mortality in high parity women without ikigai was 1.56 (95% CI: 1.00-2.45). Nulliparous or high parity women without ikigai had higher mortality from stroke and/or total CVD, suggesting that ikigai attenuated the association between parity and CVD mortality in Japanese women.

  16. Association of resting heart rate and cardiovascular disease mortality in hypertensive and normotensive rural Chinese.

    PubMed

    Zhang, Ming; Han, Chengyi; Wang, Chongjian; Wang, Jinjin; Li, Linlin; Zhang, Lu; Wang, Bingyuan; Ren, Yongcheng; Zhang, Hongyan; Yang, Xiangyu; Zhao, Yang; Zhou, Junmei; Pang, Chao; Yin, Lei; Feng, Tianping; Zhao, Jingzhi; Luo, Xinping; Hu, Dongsheng

    2017-05-01

    Studies have demonstrated an increased risk of cardiovascular disease (CVD)-associated death (CVD death) with increased resting heart rate (RHR); however, whether the association is consistent in rural Chinese with hypertension and normotension is unknown. We examined the association of RHR and CVD death by hypertension and normotension status in rural Chinese people. Baseline data for 20,069 participants ≥18 years old were collected during July to August of 2007 and July to August of 2008; 17,151 (85.5%) participants were followed up in July to August of 2013 and July to October of 2014. The association of RHR and CVD death was determined by Cox proportional hazards regression. During a mean of 5.88 years (100,889 person-years) of follow-up, we recorded 479 CVD deaths (309 in hypertensive participants). CVD death increased significantly with increasing RHR, beginning from 80 beats per minute (bpm), for hypertensive and normotensive participants. After adjusting for pulse pressure and other covariates, for hypertensive participants, risk of CVD death was increased with RHR 80-89 and ≥90bpm. However, for normotensive participants, risk of CVD death was increased with only RHR≥90bpm. Risk of CVD death was associated with elevated RHR for both hypertensive and normotensive rural Chinese, and for hypertensive participants, even slightly elevated RHR was associated with CVD death. Copyright © 2016 Japanese College of Cardiology. Published by Elsevier Ltd. All rights reserved.

  17. Canada's contribution to global research in cardiovascular diseases.

    PubMed

    Nguyen, Hai V; de Oliveira, Claire; Wijeysundera, Harindra C; Wong, William W L; Woo, Gloria; Grootendorst, Paul; Liu, Peter P; Krahn, Murray D

    2013-06-01

    The burden of cardiovascular disease (CVD) in Canada and other developed countries is growing, in part because of the aging of the population and the alarming rise of obesity. Studying Canada's contribution to the global body of CVD research output will shed light on the effectiveness of investments in Canadian CVD research and inform if Canada has been responding to its CVD burden. Search was conducted using the Web-of-Science database for publications during 1981 through 2010 on major areas and specific interventions in CVD. Search was also conducted using Canadian and US online databases for patents issued between 1981 and 2010. Search data were used to estimate the proportions of the world's pool of research publications and of patents conducted by researchers based in Canada. The results indicate that Canada contributed 6% of global research in CVD during 1981 through 2010. Further, Canada's contribution shows a strong upward trend during the period. Based on patent data, Canada's contribution level was similar (5%-7%). Canada's contribution to the global pool of CVD research is on par with France and close to the UK, Japan, and Germany. Canada's contribution in global CVD research is higher than its average contribution in all fields of research (6% vs 3%). As the burden of chronic diseases including CVD rises with Canada's aging population, the increase in Canadian research into CVD is encouraging. Copyright © 2013 Canadian Cardiovascular Society. Published by Elsevier Inc. All rights reserved.

  18. Physical Therapists’ Perceptions of Knowledge and Clinical Behavior Regarding Cardiovascular Disease Prevention

    PubMed Central

    Van Zant, R Scott; Cape, Kelly Jo; Roach, Katrina; Sweeney, Janie

    2013-01-01

    Purpose The study purpose was to assess perceptions of physical therapists (PTs) regarding the role of physical therapy in cardiovascular disease (CVD) prevention. Methods A 25-item survey, validated by expert cardiovascular/pulmonary (CVP) PTs, was sent electronically to 2,673 PTs. Each item represented an element of clinical practice behavior: education of CVD/risk factors (EDCVD), administration of primary CVD prevention (PRECVD), identifying underlying CVD/risk factors (IDCVD), monitoring CV status in patients with CVD (MONCVD). Responses were assigned numeric values (strongly agree = 5 to strongly disagree = 1), and mean element scores were analyzed. Results Most of the 516 respondents were APTA Section members (34% CVP Section, 42% other Section membership) and worked in academia (53%). Items showing a high (> 95%) level of agreement included patient education of smoking (97%) and monitoring exercise intensity (99%), assessing exercise benefits (99%), clinically identifying obesity (97%) and hypertension (97%), and monitoring CV response to exercise (99%). Items failing to reach 80% overall agreement were patient education of CVD medications (79%) and blood chemistry (72%), and assessing CVD family history (75%), patient BMI (60%), and body composition (33%). Identifying underlying CVD (77.2%) was the only practice behavior failing to reach 80% agreement. Outpatient PTs agreed significantly less to all elements vs. academics, and to IDCVD vs. all PTs except home health. Conclusions Physical therapists support most CVD prevention behaviors, but not given elements of patient education and identifying underlying CVD/risk factors. PMID:23801901

  19. Circulating interleukin-10 and risk of cardiovascular events: a prospective study in the elderly at risk.

    PubMed

    Welsh, Paul; Murray, Heather M; Ford, Ian; Trompet, Stella; de Craen, Anton J M; Jukema, J Wouter; Stott, David J; McInnes, Iain B; Packard, Chris J; Westendorp, Rudi G J; Sattar, Naveed

    2011-10-01

    The goal of this study was to examine the association of the antiinflammatory interleukin-10 (IL-10) with risk of cardiovascular disease (CVD). In the PROSPER (PROspective Study of Pravastatin in the Elderly at Risk) cohort, we related baseline concentrations of circulating IL-10 to risk of CVD events in a nested case (n=819)-control (n=1618) study of 3.2 years of follow-up. Circulating IL-10 showed few strong associations with classical risk factors but was positively correlated with IL-6 and C-reactive protein. IL-10 was positively associated with risk of CVD events (odds ratio [OR] 1.17, 95% CI 1.05 to 1.31 per unit increase in log IL-10) after adjusting for classical risk factors and C-reactive protein. Furthermore, IL-10 was associated more strongly with CVD risk among those with no previous history of CVD (OR 1.42, 95% CI 1.18 to 1.70), compared with those with previous CVD (OR 1.04, 95% CI 0.90 to 1.19; P=0.018). Overall, IL-10 showed a modest ability to add discrimination to classical risk factors (C-statistic +0.005, P=0.002). Baseline circulating levels of the antiinflammatory IL-10 are positively associated with risk of CVD among the elderly without prior CVD events, although the association is less evident in those with a history of CVD. Additional epidemiological and mechanistic studies investigating the role of IL-10 in CVD are warranted.

  20. The health effects of US unemployment insurance policy: does income from unemployment benefits prevent cardiovascular disease?

    PubMed

    Walter, Stefan; Glymour, Maria; Avendano, Mauricio

    2014-01-01

    Previous studies suggest that unemployment predicts increased cardiovascular disease (CVD) risk, but whether unemployment insurance programs mitigate this risk has not been assessed. Exploiting US state variations in unemployment insurance benefit programs, we tested the hypothesis that more generous benefits reduce CVD risk. Cohort data came from 16,108 participants in the Health and Retirement Study (HRS) aged 50-65 at baseline interviewed from 1992 to 2010. Data on first and recurrent CVD diagnosis assessed through biennial interviews were linked to the generosity of unemployment benefit programmes in each state and year. Using state fixed-effect models, we assessed whether state changes in the generosity of unemployment benefits predicted CVD risk. States with higher unemployment benefits had lower incidence of CVD, so that a 1% increase in benefits was associated with 18% lower odds of CVD (OR:0.82, 95%-CI:0.71-0.94). This association remained after introducing US census regional division fixed effects, but disappeared after introducing state fixed effects (OR:1.02, 95%-CI:0.79-1.31).This was consistent with the fact that unemployment was not associated with CVD risk in state-fixed effect models. Although states with more generous unemployment benefits had lower CVD incidence, this appeared to be due to confounding by state-level characteristics. Possible explanations are the lack of short-term effects of unemployment on CVD risk. Future studies should assess whether benefits at earlier stages of the life-course influence long-term risk of CVD.