Science.gov

Sample records for deeply-virtual compton scattering

  1. Deeply virtual Compton scattering

    NASA Astrophysics Data System (ADS)

    Marukyan, Hrachya

    2015-11-01

    This paper reviews the experimental measurements in the field of deeply virtual Compton scattering and related theoretical efforts aimed for the extraction of generalized parton distributions, objects, describing the three-dimensional structure of nucleons and nuclei. The future experiments and theoretical expectations are also considered.

  2. Weak Deeply Virtual Compton Scattering

    SciTech Connect

    Ales Psaker; Wolodymyr Melnitchouk; Anatoly Radyushkin

    2007-03-01

    We extend the analysis of the deeply virtual Compton scattering process to the weak interaction sector in the generalized Bjorken limit. The virtual Compton scattering amplitudes for the weak neutral and charged currents are calculated at the leading twist within the framework of the nonlocal light-cone expansion via coordinate space QCD string operators. Using a simple model, we estimate cross sections for neutrino scattering off the nucleon, relevant for future high intensity neutrino beam facilities.

  3. Deeply Virtual Compton Scattering with CLAS

    SciTech Connect

    F.X. Girod

    2007-12-17

    The beam spin asymmetries of the reaction ep -> epg in the Bjorken regime were measured over a wide kinematical domain using the CLAS detector and a new lead-tungstate calorimeter. Through the interference of the Bethe-Heitler process with Deeply Virtual Compton Scattering, those asymmetries provide constraints for the nucleon Generalized Parton Distributions models. The observed shapes are in agreement with twist-2 dominance predictions.

  4. Deeply Virtual Compton Scattering off the Neutron

    SciTech Connect

    Mazouz, M.; Guillon, B.; Real, J.-S.; Voutier, E.

    2007-12-14

    The present experiment exploits the interference between the deeply virtual Compton scattering (DVCS) and the Bethe-Heitler processes to extract the imaginary part of DVCS amplitudes on the neutron and on the deuteron from the helicity-dependent D(e-vector,e{sup '}{gamma})X cross section measured at Q{sup 2}=1.9 GeV{sup 2} and x{sub B}=0.36. We extract a linear combination of generalized parton distributions (GPDs) particularly sensitive to E{sub q}, the least constrained GPD. A model dependent constraint on the contribution of the up and down quarks to the nucleon spin is deduced.

  5. Deeply virtual Compton scattering and nucleon structure

    SciTech Connect

    M. Garcon

    2006-11-01

    Deeply Virtual Compton Scattering (DVCS) is the tool of choice to study Generalized Parton Distributions (GPD) in the nucleon. After a general introduction to the subject, a review of experimental results from various facilities is given. Following the first encouraging results, new generation dedicated experiments now allow unprecedented precision and kinematical coverage. Several new results were presented during the conference, showing significant progress in this relatively new field. Prospects for future experiments are presented. The path for the experimental determination of GPDs appears now open.

  6. Deeply virtual compton scattering off the neutron.

    PubMed

    Mazouz, M; Camsonne, A; Camacho, C Muñoz; Ferdi, C; Gavalian, G; Kuchina, E; Amarian, M; Aniol, K A; Beaumel, M; Benaoum, H; Bertin, P; Brossard, M; Chen, J-P; Chudakov, E; Craver, B; Cusanno, F; de Jager, C W; Deur, A; Feuerbach, R; Fieschi, J-M; Frullani, S; Garçon, M; Garibaldi, F; Gayou, O; Gilman, R; Gomez, J; Gueye, P; Guichon, P A M; Guillon, B; Hansen, O; Hayes, D; Higinbotham, D; Holmstrom, T; Hyde, C E; Ibrahim, H; Igarashi, R; Jiang, X; Jo, H S; Kaufman, L J; Kelleher, A; Kolarkar, A; Kumbartzki, G; Laveissiere, G; Lerose, J J; Lindgren, R; Liyanage, N; Lu, H-J; Margaziotis, D J; Meziani, Z-E; McCormick, K; Michaels, R; Michel, B; Moffit, B; Monaghan, P; Nanda, S; Nelyubin, V; Potokar, M; Qiang, Y; Ransome, R D; Réal, J-S; Reitz, B; Roblin, Y; Roche, J; Sabatié, F; Saha, A; Sirca, S; Slifer, K; Solvignon, P; Subedi, R; Sulkosky, V; Ulmer, P E; Voutier, E; Wang, K; Weinstein, L B; Wojtsekhowski, B; Zheng, X; Zhu, L

    2007-12-14

    The present experiment exploits the interference between the deeply virtual Compton scattering (DVCS) and the Bethe-Heitler processes to extract the imaginary part of DVCS amplitudes on the neutron and on the deuteron from the helicity-dependent D(e,e'gamma)X cross section measured at Q2=1.9 GeV2 and xB=0.36. We extract a linear combination of generalized parton distributions (GPDs) particularly sensitive to E_{q}, the least constrained GPD. A model dependent constraint on the contribution of the up and down quarks to the nucleon spin is deduced. PMID:18233443

  7. Deeply Virtual Compton Scattering off the neutron

    SciTech Connect

    M. Mazouz; A. Camsonne; C. Munoz Camacho; C. Ferdi; G. Gavalian; E. Kuchina; M. Amarian; K. A. Aniol; M. Beaumel; H. Benaoum; P. Bertin; M. Brossard; J.-P. Chen; E. Chudakov; B. Craver; F. Cusanno; C.W. de Jager; A. Deur; R. Feuerbach; J.-M. Fieschi; S. Frullani; M. Garcon; F. Garibaldi; O. Gayou; R. Gilman; J. Gomez; P. Gueye; P.A.M. Guichon; B. Guillon; O. Hansen; D. Hayes; D. Higinbotham; T. Holmstrom; C.E. Hyde; H. Ibrahim; R. Igarashi; X. Jiang; H.S. Jo; L.J. Kaufman; A. Kelleher; A. Kolarkar; G. Kumbartzki; G. Laveissiere; J.J. LeRose; R. Lindgren; N. Liyanage; H.-J. Lu; D.J. Margaziotis; Z.-E. Meziani; K. McCormick; R. Michaels; B. Michel; B. Moffit; P. Monaghan; S. Nanda; V. Nelyubin; M. Potokar; Y. Qiang; R.D. Ransome; J.-S. Real; B. Reitz; Y. Roblin; J. Roche; F. Sabatie; A. Saha; S. Sirca; K. Slifer; P. Solvignon; R. Subedi; V. Sulkosky; P.E. Ulmer; E. Voutier; K. Wang; L.B. Weinstein; B. Wojtsekhowski; X. Zheng; L. Zhu

    2007-12-01

    The present experiment exploits the interference between the Deeply Virtual Compton Scattering (DVCS) and the Bethe-Heitler processes to extract the imaginary part of DVCS amplitudes on the neutron and on the deuteron from the helicity-dependent D$({\\vec e},e'\\gamma)X$ cross section measured at $Q^2$=1.9 GeV$^2$ and $x_B$=0.36. We extract a linear combination of generalized parton distributions (GPDs) particularly sensitive to $E_q$, the least constrained GPD. A model dependent constraint on the contribution of the up and down quarks to the nucleon spin is deduced.

  8. Unitarity constraints on deeply virtual Compton scattering

    NASA Astrophysics Data System (ADS)

    Laget, J. M.

    2007-11-01

    At moderately low momentum transfer (-t up to 1 GeV2) the coupling to the vector meson production channels gives the dominant contribution to real Compton and deeply virtual Compton scattering (DVCS). Starting from a Regge pole approach that successfully describes vector meson production, the singular part of the corresponding box diagrams (where the intermediate vector meson-baryon pair propagates on-shell) is evaluated without any further assumptions (unitarity). Such a treatment explains not only the unexpectedly large DVCS unpolarized cross section that has been recently measured at Jefferson Laboratory (JLab), but also all the beam spin and charge asymmetries that have been measured at JLab and Hermes, without explicit need of Generalized Parton Distributions (GPD). The issue of the relationship between the two approaches is addressed.

  9. Unitary constraints on Deeply Virtual Compton Scattering

    SciTech Connect

    J.M. Laget

    2007-11-01

    At moderately low momentum transfer ($-t$ up to 1 GeV$^2$) the coupling to the vector meson production channels gives the dominant contribution to real Compton and deeply virtual Compton scattering (DVCS). Starting from a Regge Pole approach that successfully describes vector meson production, the singular part of the corresponding box diagrams (where the intermediate vector meson-baryon pair propagates on-shell) is evaluated without any further assumptions (unitarity). Such a treatment explains not only the unexpectedly large DVCS unpolarized cross section that has been recently measured at Jefferson Laboratory (JLab), but also all the beam spin and charge asymmetries that has been measured at JLab and Hermes, without explicit need of Generalized Parton Distributions (GPD). The issue of the relationship between the two approaches is addressed.

  10. Deeply Virtual Compton Scattering off 4He

    NASA Astrophysics Data System (ADS)

    Joosten, Sylvester; CLAS Collaboration

    2015-10-01

    The European Muon Collaboration (EMC) observed the first signs of a modification of the partonic structure of the nucleon when present in a nuclear medium. The precise nature of these effects, as well as their underlying cause, is yet to be determined. The generalized parton distribution (GPD) framework provides a powerful tool to study the partonic structure of nucleons inside a nucleus. Hard exclusive leptoproduction of a real photon off a nucleon, deeply virtual Compton scattering (DVCS), is presently considered the cleanest experimental access to the GPDs, through the Compton form factors (CFFs). This is especially the case for scattering off the spin-zero helium nucleus, where only a single CFF contributes to the process. The real and imaginary parts of this CFF can be constrained through the beam-spin asymmetry (BSA). We will present the first measurements of the DVCS process off 4He using the CEBAF 6 GeV polarized electron beam and the CLAS detector at JLab. The CLAS detector was supplemented with an inner electromagnetic calorimeter for photons produced at small angles, as well as a radial time projection chamber (RTPC) to detect low-energy recoil nuclei. This setup allowed for a clean measurement of the BSA in both the coherent and incoherent channels.

  11. Double deeply virtual Compton scattering on nucleons and nuclei

    SciTech Connect

    Kopeliovich, B. Z.; Schmidt, Ivan; Siddikov, M.

    2010-07-01

    In this paper we evaluate the double deeply virtual Compton scattering on nucleons and nuclei in the framework of the color dipole model. Both the effects of quark and the gluon shadowing are taken into account.

  12. Measurement of Deeply Virtual Compton Scattering at HERMES

    SciTech Connect

    Kopytin, M.

    2005-10-06

    The measurement of azimuthal cross section asymmetries from deeply virtual Compton scattering on the proton and deuteron at HERMES is discussed. In particular results on the longitudinal target spin asymmetry as a function of the azimuthal angle and the Mandelstam t are given. The t-dependence of the asymmetry is compared with calculations based on generalized parton distribution models.

  13. New JLab/Hall A Deeply Virtual Compton Scattering results

    SciTech Connect

    Defurne, Maxime

    2015-08-01

    New data points for unpolarized Deeply Virtual Compton Scattering cross sections have been extracted from the E00-110 experiment at Q2=1.9 GeV2 effectively doubling the statistics available in the valence region. A careful study of systematic uncertainties has been performed.

  14. Deeply Virtual Compton Scattering on the Proton

    NASA Astrophysics Data System (ADS)

    Hirlinger Saylor, Nicholas; JLab, CLAS Collaboration

    2013-10-01

    DVCS on the proton was measured at Jefferson Lab with CLAS at Hall B with a polarized 5.88 GeV electron beam on an unpolarized hydrogen target. A preliminary measurement of unpolarized and polarized cross sections was made over wide kinematics, from 1GeV2 Compton form factor HIm , which is proportional to H, was extracted. In addition, we have made a comparison of measured cross sections with predictions from several different handbag based models. This measurement allows for further constraints to be placed on the various models, especially on H. Preliminary results for the extraction of the GPD H will be presented and discussed.

  15. Deeply virtual Compton scattering via color dipoles: Nonperturbative effects

    SciTech Connect

    Kopeliovich, B. Z.; Schmidt, Ivan; Siddikov, M.

    2009-02-01

    We study the deeply virtual Compton scattering amplitude within the color dipole approach. The light-cone wave function of a real photon is evaluated in the instanton vacuum model. Our parameter-free calculations are able to describe H1 data, both the absolute values and the t dependences, at medium-high values of Q{sup 2}. The Q{sup 2} dependence is found to be sensitive to the choice of the phenomenological cross section fitted to deep-inelastic scattering data.

  16. Beam-charge azimuthal asymmetry and deeply virtual Compton scattering

    NASA Astrophysics Data System (ADS)

    Airapetian, A.; Akopov, N.; Akopov, Z.; Amarian, M.; Andrus, A.; Aschenauer, E. C.; Augustyniak, W.; Avakian, R.; Avetissian, A.; Avetissian, E.; Bailey, P.; Balin, D.; Beckmann, M.; Belostotski, S.; Bianchi, N.; Blok, H. P.; Böttcher, H.; Borissov, A.; Borysenko, A.; Bouwhuis, M.; Brüll, A.; Bryzgalov, V.; Capiluppi, M.; Capitani, G. P.; Chen, T.; Ciullo, G.; Contalbrigo, M.; Dalpiaz, P. F.; Deconinck, W.; de Leo, R.; Demey, M.; de Nardo, L.; de Sanctis, E.; Devitsin, E.; di Nezza, P.; Dreschler, J.; Düren, M.; Ehrenfried, M.; Elalaoui-Moulay, A.; Elbakian, G.; Ellinghaus, F.; Elschenbroich, U.; Fabbri, R.; Fantoni, A.; Felawka, L.; Frullani, S.; Funel, A.; Gapienko, G.; Gapienko, V.; Garibaldi, F.; Garrow, K.; Gaskell, D.; Gavrilov, G.; Gharibyan, V.; Grebeniouk, O.; Gregor, I. M.; Hadjidakis, C.; Hafidi, K.; Hartig, M.; Hasch, D.; Hesselink, W. H. A.; Hillenbrand, A.; Hoek, M.; Holler, Y.; Hommez, B.; Hristova, I.; Iarygin, G.; Ivanilov, A.; Izotov, A.; Jackson, H. E.; Jgoun, A.; Kaiser, R.; Kinney, E.; Kisselev, A.; Kobayashi, T.; Kopytin, M.; Korotkov, V.; Kozlov, V.; Krauss, B.; Krivokhijine, V. G.; Lagamba, L.; Lapikás, L.; Laziev, A.; Lenisa, P.; Liebing, P.; Linden-Levy, L. A.; Lorenzon, W.; Lu, H.; Lu, J.; Lu, S.; Ma, B.-Q.; Maiheu, B.; Makins, N. C. R.; Mao, Y.; Marianski, B.; Marukyan, H.; Masoli, F.; Mexner, V.; Meyners, N.; Michler, T.; Mikloukho, O.; Miller, C. A.; Miyachi, Y.; Muccifora, V.; Murray, M.; Nagaitsev, A.; Nappi, E.; Naryshkin, Y.; Negodaev, M.; Nowak, W.-D.; Oganessyan, K.; Ohsuga, H.; Osborne, A.; Pickert, N.; Potterveld, D. H.; Raithel, M.; Reggiani, D.; Reimer, P. E.; Reischl, A.; Reolon, A. R.; Riedl, C.; Rith, K.; Rosner, G.; Rostomyan, A.; Rubacek, L.; Rubin, J.; Ryckbosch, D.; Salomatin, Y.; Sanjiev, I.; Savin, I.; Schäfer, A.; Schnell, G.; Schüler, K. P.; Seele, J.; Seidl, R.; Seitz, B.; Shanidze, R.; Shearer, C.; Shibata, T.-A.; Shutov, V.; Sinram, K.; Sommer, W.; Stancari, M.; Statera, M.; Steffens, E.; Steijger, J. J. M.; Stenzel, H.; Stewart, J.; Stinzing, F.; Tait, P.; Tanaka, H.; Taroian, S.; Tchuiko, B.; Terkulov, A.; Trzcinski, A.; Tytgat, M.; Vandenbroucke, A.; van der Nat, P. B.; van der Steenhoven, G.; van Haarlem, Y.; Vikhrov, V.; Vincter, M. G.; Vogel, C.; Volmer, J.; Wang, S.; Wendland, J.; Ye, Y.; Ye, Z.; Yen, S.; Zihlmann, B.; Zupranski, P.

    2007-01-01

    The first observation of an azimuthal cross section asymmetry with respect to the charge of the incoming lepton beam is reported from a study of hard exclusive electroproduction of real photons. The data have been accumulated by the HERMES experiment at DESY, in which the HERA 27.6 GeV electron or positron beam scattered off an unpolarized hydrogen gas target. The observed asymmetry is attributed to the interference between the Bethe-Heitler process and the deeply virtual Compton scattering (DVCS) process. The interference term is sensitive to DVCS amplitudes, which provide the most direct access to generalized parton distributions.

  17. Compton scattering: From deeply virtual to quasi-real

    NASA Astrophysics Data System (ADS)

    Belitsky, A. V.; Müller, D.; Ji, Y.

    2014-01-01

    We address the question of interpolation of the virtual Compton scattering process off a polarized nucleon target between the deeply virtual regime for the initial-state photon and its near on-shell kinematics making use of the photon helicity-dependent Compton Form Factors (CFFs) as a main ingredient of the formalism. The five-fold differential cross section for the reaction with all possible polarization options for the lepton and nucleon spins is evaluated in terms of CFFs in the rest reference frame of the initial-state nucleon. We suggest a rather simple parametrization of the Compton hadronic tensor in terms of CFFs which are free from kinematical singularities and are directly related, at large photon virtualities, to generalized parton distributions. We also provide a relation of our basis spanned by a minimal number of Dirac bilinears to the one introduced by Tarrach for the parametrization of the virtual Compton tensor and utilize the former to establish a set of equalities among our CFFs and generalized polarizabilities. As a complementary result, we express Compton scattering in the Born approximation in terms of CFFs as well.

  18. Longitudinal target-spin asymmetries for deeply virtual Compton scattering

    SciTech Connect

    Seder, E.; Biselli, A.; Pisano, S.; Niccolai, S.; Smith, G. D.; Joo, K.; Adhikari, K.; Amaryan, M. J.; Anderson, M. D.; Anefalos Pereira, S.; Avakian, H.; Battaglieri, M.; Bedlinskiy, I.; Bono, J.; Boiarinov, S.; Bosted, P.; Briscoe, W.; Brock, J.; Brooks, W. K.; Bültmann, S.; Burkert, V. D.; Carman, D. S.; Carlin, C.; Celentano, A.; Chandavar, S.; Charles, G.; Colaneri, L.; Cole, P. L.; Contalbrigo, M.; Crabb, D.; Crede, V.; D’Angelo, A.; Dashyan, N.; De Vita, R.; De Sanctis, E.; Deur, A.; Djalali, C.; Doughty, D.; Dupre, R.; El Fassi, L.; Elouadrhiri, L.; Eugenio, P.; Fedotov, G.; Fegan, S.; Filippi, A.; Fleming, J. A.; Fradi, A.; Garillon, B.; Garçon, M.; Gevorgyan, N.; Ghandilyan, Y.; Giovanetti, K. L.; Girod, F. X.; Goetz, J. T.; Gohn, W.; Gothe, R. W.; Griffioen, K. A.; Guegan, B.; Guidal, M.; Guo, L.; Hafidi, K.; Hakobyan, H.; Hanretty, C.; Harrison, N.; Hattawy, M.; Hirlinger Saylor, N.; Holtrop, M.; Hughes, S. M.; Ilieva, Y.; Ireland, D. G.; Ishkhanov, B. S.; Isupov, E. L.; Jo, H. S.; Joosten, S.; Keith, C. D.; Keller, D.; Khachatryan, G.; Khandaker, M.; Kim, A.; Kim, W.; Klein, A.; Klein, F. J.; Koirala, S.; Kubarovsky, V.; Kuhn, S. E.; Lenisa, P.; Livingston, K.; Lu, H. Y.; MacGregor, I. J. D.; Markov, N.; Mayer, M.; McKinnon, B.; Meekins, D. G.; Mineeva, T.; Mirazita, M.; Mokeev, V.; Montgomery, R.; Moody, C. I.; Moutarde, H.; Movsisyan, A.; Munoz Camacho, C.; Nadel-Turonski, P.; Niculescu, I.; Osipenko, M.; Ostrovidov, A. I.; Paolone, M.; Pappalardo, L. L.; Park, K.; Park, S.; Pasyuk, E.; Peng, P.; Phelps, W.; Pogorelko, O.; Price, J. W.; Prok, Y.; Protopopescu, D.; Puckett, A. J. R.; Ripani, M.; Rizzo, A.; Rosner, G.; Rossi, P.; Roy, P.; Sabatié, F.; Salgado, C.; Schott, D.; Schumacher, R. A.; Senderovich, I.; Simonyan, A.; Skorodumina, I.; Sokhan, D.; Sparveris, N.; Stepanyan, S.; Stoler, P.; Strakovsky, I. I.; Strauch, S.; Sytnik, V.; Taiuti, M.; Tang, W.; Tian, Y.; Ungaro, M.; Voskanyan, H.; Voutier, E.; Walford, N. K.; Watts, D. P.; Wei, X.; Weinstein, L. B.; Wood, M. H.; Zachariou, N.; Zana, L.; Zhang, J.; Zonta, I.

    2015-01-22

    A measurement of the electroproduction of photons off protons in the deeply inelastic regime was performed at Jefferson Lab using a nearly 6-GeV electron beam, a longitudinally polarized proton target and the CEBAF Large Acceptance Spectrometer. Target-spin asymmetries for ep → e'p'y events, which arise from the interference of the deeply virtual Compton scattering and the Bethe-Heitler processes, were extracted over the widest kinematics in Q2, xB, t and Φ, for 166 four-dimensional bins. In the framework of Generalized Parton Distributions (GPDs), at leading twist the t dependence of these asymmetries provides insight on the spatial distribution of the axial charge of the proton, which appears to be concentrated in its center. In conclusion, these results bring important and necessary constraints for the existing parametrizations of chiral-even GPDs.

  19. Measurement of deeply virtual compton scattering beam-spin asymmetries.

    PubMed

    Girod, F X; Niyazov, R A; Avakian, H; Ball, J; Bedlinskiy, I; Burkert, V D; De Masi, R; Elouadrhiri, L; Garçon, M; Guidal, M; Jo, H S; Joo, K; Kubarovsky, V; Kuleshov, S V; MacCormick, M; Niccolai, S; Pogorelko, O; Sabatié, F; Stepanyan, S; Stoler, P; Ungaro, M; Zhao, B; Amaryan, M J; Ambrozewicz, P; Anghinolfi, M; Asryan, G; Bagdasaryan, H; Baillie, N; Ball, J P; Baltzell, N A; Batourine, V; Battaglieri, M; Bellis, M; Benmouna, N; Berman, B L; Biselli, A S; Blaszczyk, L; Bouchigny, S; Boiarinov, S; Bradford, R; Branford, D; Briscoe, W J; Brooks, W K; Bültmann, S; Butuceanu, C; Calarco, J R; Careccia, S L; Carman, D S; Casey, L; Chen, S; Cheng, L; Cole, P L; Collins, P; Coltharp, P; Crabb, D; Crede, V; Dashyan, N; De Sanctis, E; De Vita, R; Degtyarenko, P V; Deur, A; Dharmawardane, K V; Dickson, R; Djalali, C; Dodge, G E; Donnelly, J; Doughty, D; Dugger, M; Dzyubak, O P; Egiyan, H; Egiyan, K S; El Fassi, L; Eugenio, P; Fedotov, G; Feldman, G; Funsten, H; Gavalian, G; Gilfoyle, G P; Giovanetti, K L; Goetz, J T; Gonenc, A; Gothe, R W; Griffioen, K A; Guler, N; Guo, L; Gyurjyan, V; Hafidi, K; Hakobyan, H; Hanretty, C; Hersman, F W; Hicks, K; Hleiqawi, I; Holtrop, M; Hyde, C E; Ilieva, Y; Ireland, D G; Ishkhanov, B S; Isupov, E L; Ito, M M; Jenkins, D; Johnstone, J R; Juengst, H G; Kalantarians, N; Kellie, J D; Khandaker, M; Kim, W; Klein, A; Klein, F J; Klimenko, A V; Kossov, M; Krahn, Z; Kramer, L H; Kuhn, J; Kuhn, S E; Lachniet, J; Laget, J M; Langheinrich, J; Lawrence, D; Lee, T; Livingston, K; Lu, H Y; Markov, N; Mattione, P; Mazouz, M; McKinnon, B; Mecking, B A; Mestayer, M D; Meyer, C A; Mibe, T; Michel, B; Mikhailov, K; Mirazita, M; Miskimen, R; Mokeev, V; Moriya, K; Morrow, S A; Moteabbed, M; Munevar, E; Mutchler, G S; Nadel-Turonski, P; Nasseripour, R; Niculescu, G; Niculescu, I; Niczyporuk, B B; Niroula, M R; Nozar, M; Osipenko, M; Ostrovidov, A I; Park, K; Pasyuk, E; Paterson, C; Anefalos Pereira, S; Pierce, J; Pivnyuk, N; Pocanic, D; Pozdniakov, S; Price, J W; Procureur, S; Prok, Y; Protopopescu, D; Raue, B A; Ricco, G; Ripani, M; Ritchie, B G; Rosner, G; Rossi, P; Salamanca, J; Salgado, C; Santoro, J P; Sapunenko, V; Schumacher, R A; Serov, V S; Sharabian, Y G; Sharov, D; Shvedunov, N V; Smith, E S; Smith, L C; Sober, D I; Sokhan, D; Stavinsky, A; Stepanyan, S S; Stokes, B E; Strakovsky, I I; Strauch, S; Taiuti, M; Tedeschi, D J; Tkabladze, A; Tkachenko, S; Tur, C; Vineyard, M F; Vlassov, A V; Voutier, E; Watts, D P; Weinstein, L B; Weygand, D P; Williams, M; Wolin, E; Wood, M H; Yegneswaran, A; Zana, L; Zhang, J; Zhao, Z W

    2008-04-25

    The beam-spin asymmetries in the hard exclusive electroproduction of photons on the proton (e p-->epgamma) were measured over a wide kinematic range and with high statistical accuracy. These asymmetries result from the interference of the Bethe-Heitler process and of deeply virtual Compton scattering. Over the whole kinematic range (x(B) from 0.11 to 0.58, Q2 from 1 to 4.8 GeV2, -t from 0.09 to 1.8 GeV2), the azimuthal dependence of the asymmetries is compatible with expectations from leading-twist dominance, A approximately a sinphi/(1+c cosphi). This extensive set of data can thus be used to constrain significantly the generalized parton distributions of the nucleon in the valence quark sector. PMID:18518188

  20. Longitudinal target-spin asymmetries for deeply virtual compton scattering.

    PubMed

    Seder, E; Biselli, A; Pisano, S; Niccolai, S; Smith, G D; Joo, K; Adhikari, K; Amaryan, M J; Anderson, M D; Anefalos Pereira, S; Avakian, H; Battaglieri, M; Bedlinskiy, I; Bono, J; Boiarinov, S; Bosted, P; Briscoe, W; Brock, J; Brooks, W K; Bültmann, S; Burkert, V D; Carman, D S; Carlin, C; Celentano, A; Chandavar, S; Charles, G; Colaneri, L; Cole, P L; Contalbrigo, M; Crabb, D; Crede, V; D'Angelo, A; Dashyan, N; De Vita, R; De Sanctis, E; Deur, A; Djalali, C; Doughty, D; Dupre, R; El Fassi, L; Elouadrhiri, L; Eugenio, P; Fedotov, G; Fegan, S; Filippi, A; Fleming, J A; Fradi, A; Garillon, B; Garçon, M; Gevorgyan, N; Ghandilyan, Y; Giovanetti, K L; Girod, F X; Goetz, J T; Gohn, W; Gothe, R W; Griffioen, K A; Guegan, B; Guidal, M; Guo, L; Hafidi, K; Hakobyan, H; Hanretty, C; Harrison, N; Hattawy, M; Hirlinger Saylor, N; Holtrop, M; Hughes, S M; Ilieva, Y; Ireland, D G; Ishkhanov, B S; Isupov, E L; Jo, H S; Joosten, S; Keith, C D; Keller, D; Khachatryan, G; Khandaker, M; Kim, A; Kim, W; Klein, A; Klein, F J; Koirala, S; Kubarovsky, V; Kuhn, S E; Lenisa, P; Livingston, K; Lu, H Y; MacGregor, I J D; Markov, N; Mayer, M; McKinnon, B; Meekins, D G; Mineeva, T; Mirazita, M; Mokeev, V; Montgomery, R; Moody, C I; Moutarde, H; Movsisyan, A; Munoz Camacho, C; Nadel-Turonski, P; Niculescu, I; Osipenko, M; Ostrovidov, A I; Paolone, M; Pappalardo, L L; Park, K; Park, S; Pasyuk, E; Peng, P; Phelps, W; Pogorelko, O; Price, J W; Prok, Y; Protopopescu, D; Puckett, A J R; Ripani, M; Rizzo, A; Rosner, G; Rossi, P; Roy, P; Sabatié, F; Salgado, C; Schott, D; Schumacher, R A; Senderovich, I; Simonyan, A; Skorodumina, I; Sokhan, D; Sparveris, N; Stepanyan, S; Stoler, P; Strakovsky, I I; Strauch, S; Sytnik, V; Taiuti, M; Tang, W; Tian, Y; Ungaro, M; Voskanyan, H; Voutier, E; Walford, N K; Watts, D P; Wei, X; Weinstein, L B; Wood, M H; Zachariou, N; Zana, L; Zhang, J; Zonta, I

    2015-01-23

    A measurement of the electroproduction of photons off protons in the deeply inelastic regime was performed at Jefferson Lab using a nearly 6 GeV electron beam, a longitudinally polarized proton target, and the CEBAF Large Acceptance Spectrometer. Target-spin asymmetries for ep→e^{'}p^{'}γ events, which arise from the interference of the deeply virtual Compton scattering and the Bethe-Heitler processes, were extracted over the widest kinematics in Q^{2}, x_{B}, t, and ϕ, for 166 four-dimensional bins. In the framework of generalized parton distributions, at leading twist the t dependence of these asymmetries provides insight into the spatial distribution of the axial charge of the proton, which appears to be concentrated in its center. These results also bring important and necessary constraints for the existing parametrizations of chiral-even generalized parton distributions. PMID:25658994

  1. Deeply virtual Compton scattering from gauge/gravity duality

    SciTech Connect

    Costa, Miguel S.; Djuric, Marko

    2013-04-15

    We use gauge/gravity duality to study deeply virtual Compton scattering (DVCS) in the limit of high center of mass energy at fixed momentum transfer, corresponding to the limit of low Bjorken x, where the process is dominated by the exchange of the pomeron. At strong coupling, the pomeron is described as the graviton Regge trajectory in AdS space, with a hard wall to mimic confinement effects. This model agrees with HERA data in a large kinematical range. The behavior of the DVCS cross section for very high energies, inside saturation, can be explained by a simple AdS black disk model. In a restricted kinematical window, this model agrees with HERA data as well.

  2. Longitudinal target-spin asymmetries for deeply virtual Compton scattering

    DOE PAGESBeta

    Seder, E.; Biselli, A.; Pisano, S.; Niccolai, S.; Smith, G. D.; Joo, K.; Adhikari, K.; Amaryan, M. J.; Anderson, M. D.; Anefalos Pereira, S.; et al

    2015-01-22

    A measurement of the electroproduction of photons off protons in the deeply inelastic regime was performed at Jefferson Lab using a nearly 6-GeV electron beam, a longitudinally polarized proton target and the CEBAF Large Acceptance Spectrometer. Target-spin asymmetries for ep → e'p'y events, which arise from the interference of the deeply virtual Compton scattering and the Bethe-Heitler processes, were extracted over the widest kinematics in Q2, xB, t and Φ, for 166 four-dimensional bins. In the framework of Generalized Parton Distributions (GPDs), at leading twist the t dependence of these asymmetries provides insight on the spatial distribution of the axialmore » charge of the proton, which appears to be concentrated in its center. In conclusion, these results bring important and necessary constraints for the existing parametrizations of chiral-even GPDs.« less

  3. Deeply Virtual Compton Scattering Beam-Spin Asymmetries

    SciTech Connect

    F.X. Girod; R.A. Niyazov

    2008-01-24

    The beam spin asymmetries in the hard exclusive electroproduction of photons on the proton (ep -> epg) were measured over a wide kinematic range and with high statistical accuracy. These asymmetries result from the interference of the Bethe-Heitler process and of deeply virtual Compton scattering. Over the whole kinematic range (x_B from 0.11 to 0.58, Q^2 from 1 to 4.8 GeV^2, -t from 0.09 to 1.8 GeV^2), the azimuthal dependence of the asymmetries is compatible with expectations from leading-twist dominance, A = a*sin(phi)/[1+c*cos(phi)]. This extensive set of data can thus be used to constrain significantly the generalized parton distributions of the nucleon in the valence quark sector.

  4. Deeply Virtual Compton Scattering off ^4He nucleus

    NASA Astrophysics Data System (ADS)

    El Alaoui, Ahmed

    2010-02-01

    The recently developed formalism of generalized parton distributions (GPDs) provides a theoretical tool to reveal the internal structure of the nucleon. These objects can be obtained via Deeply Virtual Compton Scattering (DVCS) processes. They contain informations on the transverse spatial position and the longitudinal momentum of quarks inside the nucleon and they also give access to the contribution of the quark orbital angular momentum to the nucleon. In contrast to many DVCS experiments using a proton target, only few experiments are devoted to study GPDs in a nuclear target which is important because it allows to address medium modification of bound nucleon GPDs compared to free nucleon GPDs. One of the goals of the new EG6 experiment at Thomas Jefferson Laboratory is to extract the real and imaginary parts of the ^4He Compton form factor (HA(xB,t)) from measurement of beam spin asymmetries by scattering a polarized 6 GeV electron beam off a ^4He pressurized gaz target. Details on the experiment will be presented here. )

  5. Hadron Optics: Diffraction Patterns in Deeply Virtual Compton Scattering

    SciTech Connect

    Brodsky, S

    2006-05-16

    We show that the Fourier transform of the Deeply Virtual Compton Scattering (DVCS) amplitude with respect to the skewness variable {zeta} provides a unique way to visualize the light-front wavefunctions (LFWFs) of the target state in the boost-invariant longitudinal coordinate space variable ({sigma} = P{sup +}y{sup -}/2). The results are analogous to the diffractive scattering of a wave in optics in which the dependence of the amplitude on {sigma} measures the physical size of the scattering center of a one-dimensional system. If one combines this longitudinal transform with the Fourier transform of the DVCS amplitude with respect to the transverse momentum transfer {Delta}{sup {perpendicular}}, one can obtain a complete three-dimensional description of hadron optics at fixed light-front time {tau} = t + z/c. As a specific example, we utilize the quantum fluctuations of a fermion state at one loop in QED to obtain the behavior of the DVCS amplitude for electron-photon scattering. We then simulate the wavefunctions for a hadron by differentiating the above LFWFs with respect to M{sup 2} and study the corresponding DVCS amplitudes in {sigma} space.

  6. Deeply virtual Compton scattering and generalized parton distributions at CLAS

    SciTech Connect

    Niccolai, Silvia

    2008-11-01

    The exclusive electroproduction of real photons and mesons at high momentum transfer allows us to access the Generalized Parton Distributions (GPDs). The formalism of the GPDs provides a unified description of the hadronic structure in terms of quark and gluonic degrees of freedom. In particular, the Deeply Virtual Compton Scattering (DVCS), ep â e2p2Å , is one of the key reactions to determine the GPDs experimentally, as it is the simplest process that can be described in terms of GPDs. A dedicated experiment to study DVCS has been carried out in Hall B at Jefferson Lab. Beam-spin asymmetries, resulting from the interference of the Bethe-Heitler process and DVCS have been extracted over the widest kinematic range ever accessed for this reaction ( 1.2 < Q 2 < 3.7 (GeV/c 2, 0.09 < - t < 1.3 (GeV/c 2, 0.13 < x B < 0.46 . In this paper, the results obtained experimentally are shown and compared to GPD parametrizations.

  7. Deeply Virtual Compton Scattering at eRHIC

    NASA Astrophysics Data System (ADS)

    Fazio, Salvatore; Mueller, Dieter

    2012-03-01

    The feasibility for a measurement of the exclusive production of a real photon, a process although known as Deeply Virtual Compton Scattering (DVCS), using the future eRHIC machine at BNL has been explored. eRHIC is a machine designed to collide an electron beam with energies ranging from 5 GeV up to 30 GeV with the RHIC hadron beams (protons (100 -250 GeV) and nuclei (<= 100 GeV)) at varying center-of-mass energies. DVCS is universally believed to be a golden measurement toward the determination of the Generalized Parton Distribution (GPDs) functions. The high luminosity of the machine, expected in the order of 10^34cm-2s-1 at the highest center-of-mass energies, together with the large rapidity acceptance of a newly designed dedicated detector, will open the opportunity for very high precision measurements of DVCS, providing an important tool toward a 2+1 dimensional picture of the internal structure of the proton. The huge impact such measurements would have on the determination of GPDs will be discussed.

  8. Deeply virtual Compton Scattering cross section measured with CLAS

    SciTech Connect

    Guegan, Baptistse

    2014-09-01

    The Generalized Parton Distributions (GPDs) provide a new description of nucleon structure in terms of its elementary constituents, the quarks and the gluons. Including and extending the information provided by the form factors and the parton distribution functions, they describe the correlation between the transverse position and the longitudinal momentum fraction of the partons in the nucleon. Deeply Virtual Compton Scattering (DVCS), the electroproduction of a real photon on a single quark in the nucleon eN --> e'N'g, is the exclusive process most directly interpretable in terms of GPDs. A dedicated experiment to study DVCS with the CLAS detector at Jefferson Lab has been carried out using a 5.9-GeV polarized electron beam and an unpolarized hydrogen target, allowing us to collect DVCS events in the widest kinematic range ever explored in the valence region : 1.0 < Q2 < 4.6 GeV2, 0.1 < xB < 0.58 and 0.09 < -t < 2.0 GeV2. In this paper, we show preliminary results of unpolarized cross sections and of polarized cross section differences for the DVCS channel.

  9. Some Issues in Deeply-Virtual Compton Scattering

    NASA Astrophysics Data System (ADS)

    Bakker, B. L. G.; Ji, C.-R.

    2010-04-01

    Compton scattering provides a unique tool for studying hadron structure. In contrast to elastic electron scattering, which provides information about the hadron's structure in terms of form factors, Compton scattering is more versatile, as the basic process is the coupling of two electro-magnetic currents. Therefore, the hadronic structure can be described at high momentum transfer in the language of generalized parton distributions (GPDs), which code information about the light-front wave functions of the probed hadrons. In this paper we discuss some issues involved in the application of the GPD idea, in particular the effectivity of Compton scattering as a filter of the hadron structure.

  10. A-dependence of the Beam-Spin Azimuthal Asymmetry in Deeply Virtual Compton Scattering

    SciTech Connect

    Guler, Hayg

    2007-06-13

    The nuclear-mass dependence of the beam-spin asymmetry (BSA) in deeply virtual Compton scattering has been measured at HERMES. The BSA ratios of Nuclei to Hydrogen or Deuterium BSAs have been extracted in coherent and incoherent-enriched kinematic regions separately.

  11. Deeply virtual Compton scattering on longitudinally polarized protons and neutrons at CLAS

    SciTech Connect

    Silvia Niccolai

    2012-04-01

    This paper focuses on a measurement of deeply virtual Compton scattering (DVCS) performed at Jefferson Lab using a nearly-6-GeV polarized electron beam, two longitudinally polarized (via DNP) solid targets of protons (NH{sub 3}) and deuterons (ND{sub 3}) and the CEBAF Large Acceptance Spectrometer. Here, preliminary results for target-spin asymmetries and double (beam-target) asymmetries for proton DVCS, as well as a very preliminary extraction of beam-spin asymmetry for neutron DVCS, are presented and linked to Generalized Parton Distributions.

  12. Scaling Tests of the Cross Section for Deeply Virtual Compton Scattering

    NASA Astrophysics Data System (ADS)

    Camacho, C. Muñoz; Camsonne, A.; Mazouz, M.; Ferdi, C.; Gavalian, G.; Kuchina, E.; Amarian, M.; Aniol, K. A.; Beaumel, M.; Benaoum, H.; Bertin, P.; Brossard, M.; Chen, J.-P.; Chudakov, E.; Craver, B.; Cusanno, F.; de Jager, C. W.; Deur, A.; Feuerbach, R.; Fieschi, J.-M.; Frullani, S.; Garçon, M.; Garibaldi, F.; Gayou, O.; Gilman, R.; Gomez, J.; Gueye, P.; Guichon, P. A. M.; Guillon, B.; Hansen, O.; Hayes, D.; Higinbotham, D.; Holmstrom, T.; Hyde-Wright, C. E.; Ibrahim, H.; Igarashi, R.; Jiang, X.; Jo, H. S.; Kaufman, L. J.; Kelleher, A.; Kolarkar, A.; Kumbartzki, G.; Laveissière, G.; Lerose, J. J.; Lindgren, R.; Liyanage, N.; Lu, H.-J.; Margaziotis, D. J.; Meziani, Z.-E.; McCormick, K.; Michaels, R.; Michel, B.; Moffit, B.; Monaghan, P.; Nanda, S.; Nelyubin, V.; Potokar, M.; Qiang, Y.; Ransome, R. D.; Réal, J.-S.; Reitz, B.; Roblin, Y.; Roche, J.; Sabatié, F.; Saha, A.; Sirca, S.; Slifer, K.; Solvignon, P.; Subedi, R.; Sulkosky, V.; Ulmer, P. E.; Voutier, E.; Wang, K.; Weinstein, L. B.; Wojtsekhowski, B.; Zheng, X.; Zhu, L.

    2006-12-01

    We present the first measurements of the e→p→epγ cross section in the deeply virtual Compton scattering (DVCS) regime and the valence quark region. The Q2 dependence (from 1.5 to 2.3GeV2) of the helicity-dependent cross section indicates the twist-2 dominance of DVCS, proving that generalized parton distributions (GPDs) are accessible to experiment at moderate Q2. The helicity-independent cross section is also measured at Q2=2.3GeV2. We present the first model-independent measurement of linear combinations of GPDs and GPD integrals up to the twist-3 approximation.

  13. Deeply Virtual Compton Scattering off the Neutron: Measurements with CLAS and CLAS12 at Jefferson Lab

    NASA Astrophysics Data System (ADS)

    Sokhan, Daria

    Measurements of Deeply Virtual Compton Scattering (DVCS) give access to Generalised Parton Distributions (GPDs) which provide a 3D image of the nucleon and carry information on the composition of its spin. Data from both proton and neutron targets is highly desirable for an extraction of all GPDs and to allow their flavour-decomposition. Although a number of measurements have been made on proton targets, data on the neutron is almost non-existent. We present preliminary results in the extraction of beam-spin asymmetry in neutron DVCS from CLAS and the proposed experimental programme with CLAS12 at Jefferson Laboratory.

  14. Deeply Virtual Compton Scattering on the Neutron: JLab Experiment E08-025

    NASA Astrophysics Data System (ADS)

    Benali, Meriem; Mazouz, Malek; Fonvieille, Helene

    2016-03-01

    This paper gives the preliminary results of the experimental cross section for deeply virtual Compton scattering on the neutron (en → enγ). The E08-025 experiment was performed at Jefferson Lab Hall A. We measured the (D(e; eX - H(e; e'γ)X) unpolarized cross section and we extracted, for the first time, a non-zero contribution of (neutron-DVCS + coherent-deuteron-DVCS) at Q2 = 1.75 GeV2 and xB = 0.36.

  15. Scaling Tests of the Cross Section for Deeply Virtual Compton Scattering

    SciTech Connect

    Camacho, C. Munoz; Beaumel, M.; Garcon, M.; Guichon, P. A. M.; Sabatie, F.; Gavalian, G.; Amarian, M.; Hayes, D.; Hyde-Wright, C. E.; Ibrahim, H.

    2006-12-31

    We present the first measurements of the e(vector sign)p{yields}ep{gamma} cross section in the deeply virtual Compton scattering (DVCS) regime and the valence quark region. The Q{sup 2} dependence (from 1.5 to 2.3 GeV{sup 2}) of the helicity-dependent cross section indicates the twist-2 dominance of DVCS, proving that generalized parton distributions (GPDs) are accessible to experiment at moderate Q{sup 2}. The helicity-independent cross section is also measured at Q{sup 2}=2.3 GeV{sup 2}. We present the first model-independent measurement of linear combinations of GPDs and GPD integrals up to the twist-3 approximation.

  16. Exploration of deeply virtual Compton scattering on the neutron in the Hall A of Jefferson Laboratory

    SciTech Connect

    Malek Mazouz

    2006-12-08

    Generalized Parton Distributions (GPDs) are universal functions which provide a comprehensive description of hadron properties in terms of quarks and gluons. Deeply Virtual Compton Scattering (DVCS) is the simplest hard exclusive process involving GPDs. In particular, the DVCS on the neutron is mostly sensitive to E, the less constrained GPD, wich allows to access to the quark angular momentum. The first dedicated DVCS experiment on the neutron ran in the Hall A of Jefferson Lab in fall 2004. The high luminosity of the experiment and the resulting background rate recquired specific devices which are decribed in this document. The analysis methods and the experiment results, leading to preliminary constraints on the GPD E, are presented.

  17. Deeply Virtual Compton Scattering on nucleons and nuclei in generalized vector meson dominance model

    SciTech Connect

    Vadim Guzey; Klaus Goeke; Marat Siddikov

    2008-02-01

    We consider Deeply Virtual Compton Scattering (DVCS) on nucleons and nuclei in the framework of generalized vector meson dominance (GVMD) model. We demonstrate that the GVMD model provides a good description of the HERA data on the dependence of the proton DVCS cross section on $Q^2$, $W$ (at $Q^2=4$ GeV$^2$) and $t$. At $Q^2 = 8$ GeV$^2$, the soft $W$-behavior of the GVMD model somewhat underestimates the $W$-dependence of the DVCS cross section due to the hard contribution not present in the GVMD model. We estimate $1/Q^2$ power-suppressed corrections to the DVCS amplitude and the DVCS cross section and find them large. We also make predictions for the nuclear DVCS amplitude and cross section in the kinematics of the future Electron-Ion Collider. We predict significant nuclear shadowing, which matches well predictions of the leading-twist nuclear shadowing in DIS on nuclei.

  18. An Overview of Recent Deeply Virtual Compton Scattering Results at HERMES

    SciTech Connect

    Mahon, David Francis

    2009-12-17

    We present recently-released HERMES Deeply Virtual Compton Scattering results of Beam-Helicity (formerly Beam-Spin, BSA) and Beam-Charge (BCA) asymmetries from unpo-larised proton, deuteron and selected heavy nuclear gas targets. A new analysis technique utilising the ability of HERA to produce a longitudinally-polarised lepton beam of both charges has been used to simultaneously extract the BSA and BCA amplitudes arising from the DVCS-squared and Interference terms of the total cross section for proton and deuteron data. Results of the Transverse Target-Spin Asymmetry (TTSA) obtained using this technique have been published for transversely-polarised proton data. These extracted asymmetries are presented, integrated over the kinematic acceptance of the HERMES experiment for this interaction, with their dependences on -t, x{sub B} and Q{sup 2} also shown. The results are compared with asymmetries from a phenomenological model of GPDs based on double distributions.

  19. Deeply virtual compton scattering from the neutron with CLAS and CLAS12

    SciTech Connect

    Sokhan, Daria

    2014-01-01

    Generalised Parton Distributions (GPDs) offer an insight into the three-dimensional structure of the nucleon and its internal dynamics, relating the longitudinal momentum of quarks to their transverse position. A very effective means of accessing GPDs is via measurements of cross-sections and polarisation-asymmetries in Deeply Virtual Compton Scattering (DVCS). In particular, the beam-spin asymmetry (BSA) in DVCS from the neutron is especially sensitive to angular momentum of the up- and down-quarks, and its measurement therefore has potential to shed important light on the puzzle of nucleon spin. We present a preliminary extraction of BSA from a recent experiment using a 6 GeV electron beam and the CLAS detector at Jefferson Laboratory and introduce the Central Neutron Detector to be integrated with CLAS12 for the exclusive measurement of neutron DVCS at 11 GeV, made possible by the Jefferson Lab upgrade.

  20. Measurement of deeply virtual compton scattering with a polarized-proton target.

    PubMed

    Chen, S; Avakian, H; Burkert, V D; Eugenio, P; Adams, G; Amarian, M; Ambrozewicz, P; Anghinolfi, M; Asryan, G; Bagdasaryan, H; Baillie, N; Ball, J P; Baltzell, N A; Barrow, S; Batourine, V; Battaglieri, M; Beard, K; Bedlinskiy, I; Bektasoglu, M; Bellis, M; Benmouna, N; Berman, B L; Biselli, A S; Bonner, B E; Bouchigny, S; Boiarinov, S; Bosted, P; Bradford, R; Branford, D; Briscoe, W J; Brooks, W K; Bültmann, S; Butuceanu, C; Calarco, J R; Careccia, S L; Carman, D S; Carnahan, B; Cazes, A; Cole, P L; Collins, P; Coltharp, P; Cords, D; Corvisiero, P; Crabb, D; Crannell, H; Crede, V; Cummings, J P; DeMasi, R; DeVita, R; De Sanctis, E; Degtyarenko, P V; Denizli, H; Dennis, L; Deur, A; Dharmawardane, K V; Dhuga, K S; Djalali, C; Dodge, G E; Donnelly, J; Doughty, D; Dugger, M; Dytman, S; Dzyubak, O P; Egiyan, H; Egiyan, K S; El Fassi, L; Elouadrhiri, L; Fatemi, R; Fedotov, G; Feldman, G; Feuerbach, R J; Forest, T A; Funsten, H; Garçon, M; Gavalian, G; Gilfoyle, G P; Giovanetti, K L; Girod, F X; Goetz, J T; Golovatch, E; Gonenc, A; Gothe, R W; Griffioen, K A; Guidal, M; Guillo, M; Guler, N; Guo, L; Gyurjyan, V; Hadjidakis, C; Hafidi, K; Hakobyan, H; Hakobyan, R S; Hardie, J; Heddle, D; Hersman, F W; Hicks, K; Hleiqawi, I; Holtrop, M; Huertas, M; Hyde-Wright, C E; Ilieva, Y; Ireland, D G; Ishkhanov, B S; Isupov, E L; Ito, M M; Jenkins, D; Jo, H S; Joo, K; Juengst, H G; Keith, C; Kellie, J D; Khandaker, M; Kim, K Y; Kim, K; Kim, W; Klein, A; Klein, F J; Klusman, M; Kossov, M; Kramer, L H; Kubarovsky, V; Kuhn, J; Kuhn, S E; Kuleshov, S V; Lachniet, J; Laget, J M; Langheinrich, J; Lawrence, D; Li, Ji; Lima, A C S; Livingston, K; Lu, H; Lukashin, K; MacCormick, M; Markov, N; McAleer, S; McKinnon, B; McNabb, J W C; Mecking, B A; Mestayer, M D; Meyer, C A; Mibe, T; Mikhailov, K; Minehart, R; Mirazita, M; Miskimen, R; Mokeev, V; Morand, L; Morrow, S A; Moteabbed, M; Mueller, J; Mutchler, G S; Nadel-Turonski, P; Napolitano, J; Nasseripour, R; Natasha, N; Niccolai, S; Niculescu, G; Niculescu, I; Niczyporuk, B B; Niroula, M R; Niyazov, R A; Nozar, M; O'Rielly, G V; Osipenko, M; Ostrovidov, A I; Park, K; Pasyuk, E; Paterson, C; Philips, S A; Pierce, J; Pivnyuk, N; Pocanic, D; Pogorelko, O; Polli, E; Popa, I; Pozdniakov, S; Preedom, B M; Price, J W; Prok, Y; Protopopescu, D; Qin, L M; Raue, B A; Riccardi, G; Ricco, G; Ripani, M; Ritchie, B G; Ronchetti, F; Rosner, G; Rossi, P; Rowntree, D; Rubin, P D; Sabatié, F; Salgado, C; Santoro, J P; Sapunenko, V; Schumacher, R A; Serov, V S; Sharabian, Y G; Shaw, J; Shvedunov, N V; Skabelin, A V; Smith, E S; Smith, L C; Sober, D I; Stavinsky, A; Stepanyan, S S; Stepanyan, S; Stokes, B E; Stoler, P; Strakovsky, I I; Strauch, S; Suleiman, R; Taiuti, M; Tedeschi, D J; Thoma, U; Tkabladze, A; Tkachenko, S; Todor, L; Tur, C; Ungaro, M; Vanderhaeghen, M; Vineyard, M F; Vlassov, A V; Watts, D P; Weinstein, L B; Weygand, D P; Williams, M; Wolin, E; Wood, M H; Yegneswaran, A; Yun, J; Zana, L; Zhang, J; Zhao, B; Zhao, Z

    2006-08-18

    The longitudinal target-spin asymmetry AUL for the exclusive electroproduction of high-energy photons was measured for the first time in ep-->e;'pgamma. The data have been accumulated at JLab with the CLAS spectrometer using 5.7 GeV electrons and a longitudinally polarized NH3 target. A significant azimuthal angular dependence was observed, resulting from the interference of the deeply virtual Compton scattering and Bethe-Heitler processes. The amplitude of the sinvarphi moment is 0.252+/-0.042stat+/-0.020sys. Theoretical calculations are in good agreement with the magnitude and the kinematic dependence of the target-spin asymmetry, which is sensitive to the generalized parton distributions H and H. PMID:17026221

  1. Scaling tests of the cross section for deeply virtual Compton scattering.

    PubMed

    Camacho, C Muñoz; Camsonne, A; Mazouz, M; Ferdi, C; Gavalian, G; Kuchina, E; Amarian, M; Aniol, K A; Beaumel, M; Benaoum, H; Bertin, P; Brossard, M; Chen, J-P; Chudakov, E; Craver, B; Cusanno, F; de Jager, C W; Deur, A; Feuerbach, R; Fieschi, J-M; Frullani, S; Garçon, M; Garibaldi, F; Gayou, O; Gilman, R; Gomez, J; Gueye, P; Guichon, P A M; Guillon, B; Hansen, O; Hayes, D; Higinbotham, D; Holmstrom, T; Hyde-Wright, C E; Ibrahim, H; Igarashi, R; Jiang, X; Jo, H S; Kaufman, L J; Kelleher, A; Kolarkar, A; Kumbartzki, G; Laveissière, G; Lerose, J J; Lindgren, R; Liyanage, N; Lu, H-J; Margaziotis, D J; Meziani, Z-E; McCormick, K; Michaels, R; Michel, B; Moffit, B; Monaghan, P; Nanda, S; Nelyubin, V; Potokar, M; Qiang, Y; Ransome, R D; Réal, J-S; Reitz, B; Roblin, Y; Roche, J; Sabatié, F; Saha, A; Sirca, S; Slifer, K; Solvignon, P; Subedi, R; Sulkosky, V; Ulmer, P E; Voutier, E; Wang, K; Weinstein, L B; Wojtsekhowski, B; Zheng, X; Zhu, L

    2006-12-31

    We present the first measurements of the e[over -->]p-->epgamma cross section in the deeply virtual Compton scattering (DVCS) regime and the valence quark region. The Q(2) dependence (from 1.5 to 2.3 GeV(2)) of the helicity-dependent cross section indicates the twist-2 dominance of DVCS, proving that generalized parton distributions (GPDs) are accessible to experiment at moderate Q(2). The helicity-independent cross section is also measured at Q(2)=2.3 GeV(2). We present the first model-independent measurement of linear combinations of GPDs and GPD integrals up to the twist-3 approximation. PMID:17280421

  2. Hadron Optics in Three-Dimensional Invariant Coordinate Space from Deeply Virtual Compton Scattering

    SciTech Connect

    Brodsky, S J; Chakrabarti, D; Harindranath, A; Mukherjee, A; Vary, J P

    2006-11-10

    The Fourier transform of the deeply virtual Compton scattering amplitude (DVCS) with respect to the skewness parameter {zeta} = Q{sup 2}/2p {center_dot} q can be used to provide an image of the target hadron in the boost-invariant variable {sigma}, the coordinate conjugate to light-front time {tau} = t + z/c. As an illustration, we construct a consistent covariant model of the DVCS amplitude and its associated generalized parton distributions using the quantum fluctuations of a fermion state at one loop in QED, thus providing a representation of the light-front wavefunctions of a lepton in {sigma} space. A consistent model for hadronic amplitudes can then be obtained by differentiating the light-front wavefunctions with respect to the bound-state mass. The resulting DVCS helicity amplitudes are evaluated as a function of {sigma} and the impact parameter {rvec b}{sub {perpendicular}}, thus providing a light-front ''photograph'' of the target hadron in a frame-independent three-dimensional light-front coordinate space. We find that in the models studied, the Fourier transform of the DVCS amplitudes exhibit diffraction patterns. The results are analogous to the diffractive scattering of a wave in optics where the distribution in {sigma} measures the physical size of the scattering center in a one-dimensional system.

  3. Hadron Optics in Three-Dimensional Invariant Coordinate Space from Deeply VirtualCompton Scattering

    SciTech Connect

    Brodsky, S.J.; Chakrabarti, D.; Harindranath, A.; Mukherjee, A.; Vary, J.P.

    2006-11-30

    The Fourier transform of the deeply virtual Compton scattering amplitude (DVCS) with respect to the skewness parameter {zeta} = Q{sup 2}/2p {center_dot} q can be used to provide an image of the target hadron in the boost-invariant variable {sigma}, the coordinate conjugate to light-front time {tau} = t + z/c. As an illustration, we construct a consistent covariant model of the DVCS amplitude and its associated generalized parton distributions using the quantum fluctuations of a fermion state at one loop in QED, thus providing a representation of the light-front wave functions of a lepton in {sigma} space. A consistent model for hadronic amplitudes can then be obtained by differentiating the light-front wave functions with respect to the bound-state mass. The resulting DVCS helicity amplitudes are evaluated as a function of {sigma} and the impact parameter {rvec b}{sub {perpendicular}}, thus providing a light-front image of the target hadron in a frame-independent three-dimensional light-front coordinate space. Models for the LFWFs of hadrons in (3 + 1) dimensions displaying confinement at large distances and conformal symmetry at short distances have been obtained using the AdS/CFT method. We also compute the LFWFs in this model in invariant three dimensional coordinate space. We find that in the models studied, the Fourier transform of the DVCS amplitudes exhibit diffraction patterns. The results are analogous to the diffractive scattering of a wave in optics where the distribution in ? measures the physical size of the scattering center in a one-dimensional system.

  4. Nuclear-mass dependence of azimuthal beam-helicity and beam-charge asymmetries in deeply virtual Compton scattering

    NASA Astrophysics Data System (ADS)

    Airapetian, A.; Akopov, N.; Akopov, Z.; Amarian, M.; Aschenauer, E. C.; Augustyniak, W.; Avakian, R.; Avetissian, A.; Avetisyan, E.; Ball, B.; Belostotski, S.; Bianchi, N.; Blok, H. P.; Böttcher, H.; Borissov, A.; Bowles, J.; Bryzgalov, V.; Burns, J.; Capiluppi, M.; Capitani, G. P.; Cisbani, E.; Ciullo, G.; Contalbrigo, M.; Dalpiaz, P. F.; Deconinck, W.; Leo, R. De; Nardo, L. De; Sanctis, E. De; Diefenthaler, M.; Nezza, P. Di; Düren, M.; Ehrenfried, M.; Elbakian, G.; Ellinghaus, F.; Fabbri, R.; Fantoni, A.; Felawka, L.; Frullani, S.; Gabbert, D.; Gapienko, G.; Gapienko, V.; Garibaldi, F.; Gavrilov, G.; Gharibyan, V.; Giordano, F.; Gliske, S.; Guler, H.; Guzey, V.; Haan, S.; Hadjidakis, C.; Hartig, M.; Hasch, D.; Hill, G.; Hillenbrand, A.; Hoek, M.; Holler, Y.; Hristova, I.; Imazu, Y.; Ivanilov, A.; Jackson, H. E.; Jo, H. S.; Joosten, S.; Kaiser, R.; Karyan, G.; Keri, T.; Kinney, E.; Kisselev, A.; Korotkov, V.; Kozlov, V.; Kravchenko, P.; Lagamba, L.; Lamb, R.; Lapikás, L.; Lehmann, I.; Lenisa, P.; López Ruiz, A.; Lorenzon, W.; Lu, X.-G.; Lu, X.-R.; Ma, B.-Q.; Mahon, D.; Makins, N. C. R.; Manaenkov, S. I.; Manfré, L.; Mao, Y.; Marianski, B.; de La Ossa, A. Martinez; Marukyan, H.; Miller, C. A.; Miyachi, Y.; Movsisyan, A.; Muccifora, V.; Murray, M.; Mussgiller, A.; Nappi, E.; Naryshkin, Y.; Nass, A.; Negodaev, M.; Nowak, W.-D.; Pappalardo, L. L.; Perez-Benito, R.; Raithel, M.; Reimer, P. E.; Reolon, A. R.; Riedl, C.; Rith, K.; Rosner, G.; Rostomyan, A.; Rubin, J.; Ryckbosch, D.; Salomatin, Y.; Schäfer, A.; Schnell, G.; Schüler, K. P.; Shanidze, R.; Shibata, T.-A.; Shutov, V.; Stancari, M.; Statera, M.; Steffens, E.; Steijger, J. J. M.; Stewart, J.; Stinzing, F.; Taroian, S.; Terkulov, A.; Trzcinski, A.; Tytgat, M.; Vandenbroucke, A.; Haarlem, Y. Van; Hulse, C. Van; Varanda, M.; Veretennikov, D.; Vikhrov, V.; Vilardi, I.; Wang, S.; Yaschenko, S.; Ye, H.; Ye, Z.; Yu, W.; Zeiler, D.; Zihlmann, B.; Zupranski, P.; sHERMES Collaboration

    2010-03-01

    The nuclear-mass dependence of azimuthal cross-section asymmetries with respect to charge and longitudinal polarization of the lepton beam is studied for hard exclusive electroproduction of real photons. The observed beam-charge and beam-helicity asymmetries are attributed to the interference between the Bethe-Heitler and the deeply virtual Compton scattering processes. For various nuclei, the asymmetries are extracted for both coherent and incoherent-enriched regions, which involve different (combinations of) generalized parton distributions. For both regions, the asymmetries are compared to those for a free proton, and no nuclear-mass dependence is found.

  5. Timelike deeply virtual Compton scattering with a linearly polarized real (or quasi-real) photon beam

    NASA Astrophysics Data System (ADS)

    Goritschnig, A.; Pire, B.; Wagner, J.

    We calculate timelike virtual Compton scattering amplitudes in the generalized Bjorken scaling regime and focus on a new polarization asymmetry in the scattering process with a linearly polarized photon beam in the medium energy range, which will be studied intensely at JLab12 experiments. We demonstrate that new observables help us to access the polarized quark and gluon generalized parton distributions $\\tilde H(x, \\xi, t)$ and $ \\tilde E(x, \\xi, t)$.

  6. Scaling Tests of the Cross Section for Deeply Virtual Compton Scattering

    SciTech Connect

    Carlos Munoz Camacho; Alexandre Camsonne; Malek Mazouz; Catherine Ferdi; Gagik Gavalian; Elena Kuchina; Moscov Amaryan; Konrad Aniol; Matthieu Beaumel; Hachemi Benaoum; Pierre Bertin; Michel Brossard; Jian-Ping Chen; Eugene Chudakov; Brandon Craver; Francesco Cusanno; Kees de Jager; Alexandre Deur; Robert Feuerbach; Jean Fieschi; Salvatore Frullani; Michel Garcon; Franco Garibaldi; Olivier Gayou; Ronald Gilman; Javier Gomez; Paul Gueye; Pierre Guichon; Benoit Guillon; Jens-ole Hansen; David Hayes; Douglas Higinbotham; Timothy Holmstrom; Charles Hyde-Wright; Hassan Ibrahim; Ryuichi Igarashi; Xiaodong Jiang; Hyon-Suk Jo; Lisa Kaufman; Aidan Kelleher; Ameya Kolarkar; Gerfried Kumbartzki; Geraud Laveissiere; John LeRose; Richard Lindgren; Nilanga Liyanage; Hai-jiang Lu; Demetrius Margaziotis; Zein-Eddine Meziani; Kathy McCormick; Robert Michaels; Bernard Michel; Bryan Moffit; Peter Monaghan; Sirish Nanda; Vladimir Nelyubin; Milan Potokar; Yi Qiang; Ronald Ransome; Jean-Sebastien Real; Bodo Reitz; Yves Roblin; Julie Roche; Franck Sabatie; Arunava Saha; Simon Sirca; Karl Slifer; Patricia Solvignon; Ramesh Subedi; Vincent Sulkosky; Paul Ulmer; Eric Voutier; Kebin Wang; Lawrence Weinstein; Bogdan Wojtsekhowski; Xiaochao Zheng; Lingyan Zhu

    2006-07-27

    We present the first measurements of {rvec e}p {yields} ep{gamma} cross section in the deep virtual Compton scattering (DVCS) regime and the valence quark region (x{sub Bj} = 0.36). From JLab E00-110, we extract the imaginary part of the Bethe-Heitler (BH)--DVCS interference terms, to order twist-3 for Q{sup 2} = 1.5, 1.9, and 2.3 GeV{sup 2}, and the real part of the BH-DVCS interference terms at Q{sup 2}2 = 2.3 GeV{sup 2}. We present the first model-independent measurement of linear combinations of generalized parton distributions (GPDs) and GPD integrals up to twist-3 approximation. The validity of this approximation is strongly supported by the absence of Q{sup 2}-variation of the extracted terms--thereby constraining the size of higher twist contributions to our observables.

  7. Beam spin asymmetries in deeply virtual Compton scattering (DVCS) with CLAS at 4.8 GeV

    NASA Astrophysics Data System (ADS)

    Gavalian, G.; Burkert, V. D.; Elouadrhiri, L.; Holtrop, M.; Stepanyan, S.; Abrahamyan, D.; Adams, G.; Amaryan, M. J.; Ambrozewicz, P.; Anghinolfi, M.; Asavapibhop, B.; Asryan, G.; Avakian, H.; Bagdasaryan, H.; Baillie, N.; Ball, J. P.; Baltzell, N. A.; Barrow, S.; Batourine, V.; Battaglieri, M.; Beard, K.; Bedlinskiy, I.; Bektasoglu, M.; Bellis, M.; Benmouna, N.; Berman, B. L.; Biselli, A. S.; Bonner, B. E.; Bouchigny, S.; Boiarinov, S.; Bradford, R.; Branford, D.; Briscoe, W. J.; Brooks, W. K.; Bültmann, S.; Butuceanu, C.; Calarco, J. R.; Careccia, S. L.; Carman, D. S.; Carnahan, B.; Chen, S.; Cole, P. L.; Coleman, A.; Collins, P.; Coltharp, P.; Cords, D.; Corvisiero, P.; Crabb, D.; Crannell, H.; Crede, V.; Cummings, J. P.; Dashyan, N.; de Masi, R.; de Vita, R.; de Sanctis, E.; Degtyarenko, P. V.; Denizli, H.; Dennis, L.; Deur, A.; Dharmawardane, K. V.; Dhuga, K. S.; Dickson, R.; Djalali, C.; Dodge, G. E.; Donnelly, J.; Doughty, D.; Dragovitsch, P.; Dugger, M.; Dytman, S.; Dzyubak, O. P.; Egiyan, H.; Egiyan, K. S.; Fassi, L. El; Empl, A.; Eugenio, P.; Fatemi, R.; Fedotov, G.; Feldman, G.; Feuerbach, R. J.; Forest, T. A.; Funsten, H.; Garçon, M.; Gilfoyle, G. P.; Giovanetti, K. L.; Girod, F. X.; Goetz, J. T.; Golovatch, E.; Gonenc, A.; Gothe, R. W.; Griffioen, K. A.; Guidal, M.; Guillo, M.; Guler, N.; Guo, L.; Gyurjyan, V.; Hadjidakis, C.; Hafidi, K.; Hakobyan, H.; Hakobyan, R. S.; Hardie, J.; Hassall, N.; Heddle, D.; Hersman, F. W.; Hicks, K.; Hleiqawi, I.; Hu, J.; Huertas, M.; Hyde, C. E.; Ilieva, Y.; Ireland, D. G.; Ishkhanov, B. S.; Isupov, E. L.; Ito, M. M.; Jenkins, D.; Jo, H. S.; Joo, K.; Juengst, H. G.; Kalantarians, N.; Kellie, J. D.; Khandaker, M.; Kim, K. Y.; Kim, K.; Kim, W.; Klein, A.; Klein, F. J.; Klusman, M.; Kossov, M.; Kramer, L. H.; Kubarovsky, V.; Kuhn, J.; Kuhn, S. E.; Kuleshov, S. V.; Kuznetsov, M.; Lachniet, J.; Laget, J. M.; Langheinrich, J.; Lawrence, D.; Lima, A. C. S.; Livingston, K.; Lu, H. Y.; Lukashin, K.; MacCormick, M.; Manak, J. J.; Markov, N.; McAleer, S.; McKinnon, B.; McNabb, J. W. C.; Mecking, B. A.; Mestayer, M. D.; Meyer, C. A.; Mibe, T.; Mikhailov, K.; Minehart, R.; Mirazita, M.; Miskimen, R.; Mokeev, V.; Moriya, K.; Morrow, S. A.; Moteabbed, M.; Mueller, J.; Mutchler, G. S.; Nadel-Turonski, P.; Napolitano, J.; Nasseripour, R.; Niccolai, S.; Niculescu, G.; Niculescu, I.; Niczyporuk, B. B.; Niroula, M. R.; Niyazov, R. A.; Nozar, M.; O'Rielly, G. V.; Osipenko, M.; Ostrovidov, A. I.; Park, K.; Pasyuk, E.; Paterson, C.; Philips, S. A.; Pierce, J.; Pivnyuk, N.; Pocanic, D.; Pogorelko, O.; Polli, E.; Popa, I.; Pozdniakov, S.; Preedom, B. M.; Price, J. W.; Prok, Y.; Protopopescu, D.; Qin, L. M.; Raue, B. A.; Riccardi, G.; Ricco, G.; Ripani, M.; Ritchie, B. G.; Ronchetti, F.; Rosner, G.; Rossi, P.; Rowntree, D.; Rubin, P. D.; Sabatié, F.; Salamanca, J.; Salgado, C.; Santoro, J. P.; Sapunenko, V.; Schumacher, R. A.; Serov, V. S.; Sharabian, Y. G.; Shaw, J.; Shvedunov, N. V.; Skabelin, A. V.; Smith, E. S.; Smith, L. C.; Sober, D. I.; Sokhan, D.; Stavinsky, A.; Stepanyan, S. S.; Stokes, B. E.; Stoler, P.; Strakovsky, I. I.; Strauch, S.; Suleiman, R.; Taiuti, M.; Taylor, S.; Tedeschi, D. J.; Thoma, U.; Thompson, R.; Tkabladze, A.; Tkachenko, S.; Tur, C.; Ungaro, M.; Vineyard, M. F.; Vlassov, A. V.; Watts, D. P.; Weinstein, L. B.; Weygand, D. P.; Williams, M.; Wolin, E.; Wood, M. H.; Yegneswaran, A.; Yun, J.; Yurov, M.; Zana, L.; Zhang, J.; Zhao, B.; Zhao, Z. W.

    2009-09-01

    We report measurements of the beam spin asymmetry in deeply virtual Compton scattering (DVCS) at an electron beam energy of 4.8 GeV using the CLAS detector at the Thomas Jefferson National Accelerator Facility. The DVCS beam spin asymmetry has been measured in a wide range of kinematics, 1.0

  8. Measurement of Deeply Virtual Compton Scattering (DVCS) cross sections with CLAS

    SciTech Connect

    Hyon-Suk Jo

    2012-04-01

    Extraction of DVCS unpolarized and polarized cross sections in the largest kinematic domain ever explored in the valence region. Results are in good agreement with GPD model (VGG) predictions. Extraction of Compton Form Factors (M. Guidal) by fitting simultaneously these unpolarizedand polarized cross sections gives a large set of results in a very large kinematic domain for Re(H ) and Im(H ). Analysis of the data from the second part of the e1-DVCS experiment underway.

  9. Study of Generalized Parton Distributions and Deeply Virtual Compton Scattering on the nucleon with the CLAS and CLAS12 detectors at the Jefferson Laboratory

    SciTech Connect

    Guegan, Baptiste

    2012-11-01

    The exclusive leptoproduction of a real photon is considered to be the "cleanest" way to access the Generalized Parton Distribution (GPD). This process is called Deeply Virtual Compton Scattering (DVCS) lN {yields} lN{gamma} , and is sensitive to all the four GPDs. Measuring the DVCS cross section is one of the main goals of this thesis. In this thesis, we present the work performed to extract on a wide phase-space the DVCS cross-section from the JLab data at a beam energy of 6 GeV.

  10. Model-Dependent Constraint on Quark Total Angular Momentum Based on the Transverse Target-spin Asymmetry Measured in Deeply Virtual Compton Scattering at HERMES

    SciTech Connect

    Nowak, Wolf-Dieter

    2007-06-13

    Results are reported on the transverse target-spin asymmetry (TTSA) associated with deeply virtual Compton scattering on the proton. The data have been accumulated in the years 2002-2004 by the HERMES experiment at DESY, in which the HERA 27.6 GeV e+ beam scattered on a transversely polarized hydrogen target. Two azimuthal amplitudes of the TTSA appearing to LO in 1/Q and {alpha}s, A{sub UT}{sup sin({phi}-{phi}{sub S})cos{phi}} and A{sub UT}{sup cos({phi} -{phi}{sub S})sin{phi}}, are given as a function of -t,xB,Q2 in the kinematic range |t| < 0.7 GeV2, 0.03 < xB < 0.35 and 1 < Q2 < 10 GeV2. The first amplitude is found to be sensitive to the generalized parton distribution (GPD) E of the proton, which can be parameterized in a GPD model through quark total angular momentum Jq(q = u, d). Within the context of this model, a constraint in the (Ju,Jd) plane is obtained from HERMES TTSA data.

  11. Measurements of the Electron-Helicity Dependent Cross Sections of Deeply Virtual Compton Scattering with CEBAF at 12 GeV

    SciTech Connect

    J. Roche; C. E. Hyde-Wright; B. Michel; C. Munoz Camacho; et al.

    2006-09-11

    We propose precision measurements of the helicity-dependent and helicity independent cross sections for the ep {yields} ep{gamma} reaction in Deeply Virtual Compton Scattering (DVCS) kinematics. DVCS scaling is obtained in the limits Q{sup 2} >> {Lambda}{sub QCD}{sup 2}, x{sub Bj} fixed, and -{Delta}{sup 2} = -(q-q{prime}){sup 2} << Q{sup 2}. We consider the specific kinematic range Q{sup 2} > 2 GeV{sup 2}, W > 2 GeV, and -{Delta}{sup 2} {le} 1 GeV{sup 2}. We will use our successful technique from the 5.75 GeV Hall A DVCS experiment (E00-110). With polarized 6.6, 8.8, and 11 GeV beams incident on the liquid hydrogen target, we will detect the scattered electron in the Hall A HRS-L spectrometer (maximum central momentum 4.3 GeV/c) and the emitted photon in a slightly expanded PbF{sub 2} calorimeter. In general, we will not detect the recoil proton. The H(e,e{prime}{gamma})X missing mass resolution is sufficient to isolate the exclusive channel with 3% systematic precision.

  12. E00-110 experiment at Jefferson Lab Hall A: Deeply virtual Compton scattering off the proton at 6 GeV

    SciTech Connect

    Defurne, M.; Amaryan, M.; Aniol, K. A.; Beaumel, M.; Benaoum, H.; Bertin, P.; Brossard, M.; Camsonne, A.; Chen, J. -P.; Chudakov, E.; Craver, B.; Cusanno, F.; de Jager, C. W.; Deur, A.; Feuerbach, R.; Ferdi, C.; Fieschi, J. -M.; Frullani, S.; Fuchey, E.; Garçon, M.; Garibaldi, F.; Gayou, O.; Gavalian, G.; Gilman, R.; Gomez, J.; Gueye, P.; Guichon, P. A. M.; Guillon, B.; Hansen, O.; Hayes, D.; Higinbotham, D.; Holmstrom, T.; Hyde, C. E.; Ibrahim, H.; Igarashi, R.; Jiang, X.; Jo, H. S.; Kaufman, L. J.; Kelleher, A.; Keppel, C.; Kolarkar, A.; Kuchina, E.; Kumbartzki, G.; Laveissière, G.; LeRose, J. J.; Lindgren, R.; Liyanage, N.; Lu, H. -J.; Margaziotis, D. J.; Mazouz, M.; Meziani, Z. -E.; McCormick, K.; Michaels, R.; Michel, B.; Moffit, B.; Monaghan, P.; Muñoz Camacho, C.; Nanda, S.; Nelyubin, V.; Paremuzyan, R.; Potokar, M.; Qiang, Y.; Ransome, R. D.; Réal, J. -S.; Reitz, B.; Roblin, Y.; Roche, J.; Sabatié, F.; Saha, A.; Sirca, S.; Slifer, K.; Solvignon, P.; Subedi, R.; Sulkosky, V.; Ulmer, P. E.; Voutier, E.; Wang, K.; Weinstein, L. B.; Wojtsekhowski, B.; Zheng, X.; Zhu, L.

    2015-11-03

    We present final results on the photon electroproduction ($\\vec{e}p\\rightarrow ep\\gamma$) cross section in the deeply virtual Compton scattering (DVCS) regime and the valence quark region from Jefferson Lab experiment E00-110. Results from an analysis of a subset of these data were published before, but the analysis has been improved which is described here at length, together with details on the experimental setup. Furthermore, additional data have been analyzed resulting in photon electroproduction cross sections at new kinematic settings, for a total of 588 experimental bins. Results of the $Q^2$- and $x_B$-dependences of both the helicity-dependent and helicity-independent cross sections are discussed. The $Q^2$-dependence illustrates the dominance of the twist-2 handbag amplitude in the kinematics of the experiment, as previously noted. Thanks to the excellent accuracy of this high luminosity experiment, it becomes clear that the unpolarized cross section shows a significant deviation from the Bethe-Heitler process in our kinematics, compatible with a large contribution from the leading twist-2 DVCS$^2$ term to the photon electroproduction cross section. The necessity to include higher-twist corrections in order to fully reproduce the shape of the data is also discussed. The DVCS cross sections in this study represent the final set of experimental results from E00-110, superseding the previous publication.

  13. E00-110 experiment at Jefferson Lab Hall A: Deeply virtual Compton scattering off the proton at 6 GeV

    DOE PAGESBeta

    Defurne, M.; Amaryan, M.; Aniol, K. A.; Beaumel, M.; Benaoum, H.; Bertin, P.; Brossard, M.; Camsonne, A.; Chen, J. -P.; Chudakov, E.; et al

    2015-11-03

    We present final results on the photon electroproduction (more » $$\\vec{e}p\\rightarrow ep\\gamma$$) cross section in the deeply virtual Compton scattering (DVCS) regime and the valence quark region from Jefferson Lab experiment E00-110. Results from an analysis of a subset of these data were published before, but the analysis has been improved which is described here at length, together with details on the experimental setup. Furthermore, additional data have been analyzed resulting in photon electroproduction cross sections at new kinematic settings, for a total of 588 experimental bins. Results of the $Q^2$- and $x_B$-dependences of both the helicity-dependent and helicity-independent cross sections are discussed. The $Q^2$-dependence illustrates the dominance of the twist-2 handbag amplitude in the kinematics of the experiment, as previously noted. Thanks to the excellent accuracy of this high luminosity experiment, it becomes clear that the unpolarized cross section shows a significant deviation from the Bethe-Heitler process in our kinematics, compatible with a large contribution from the leading twist-2 DVCS$^2$ term to the photon electroproduction cross section. The necessity to include higher-twist corrections in order to fully reproduce the shape of the data is also discussed. The DVCS cross sections in this study represent the final set of experimental results from E00-110, superseding the previous publication.« less

  14. E00-110 experiment at Jefferson Lab Hall A: Deeply virtual Compton scattering off the proton at 6 GeV

    NASA Astrophysics Data System (ADS)

    Defurne, M.; Amaryan, M.; Aniol, K. A.; Beaumel, M.; Benaoum, H.; Bertin, P.; Brossard, M.; Camsonne, A.; Chen, J.-P.; Chudakov, E.; Craver, B.; Cusanno, F.; de Jager, C. W.; Deur, A.; Feuerbach, R.; Ferdi, C.; Fieschi, J.-M.; Frullani, S.; Fuchey, E.; Garçon, M.; Garibaldi, F.; Gayou, O.; Gavalian, G.; Gilman, R.; Gomez, J.; Gueye, P.; Guichon, P. A. M.; Guillon, B.; Hansen, O.; Hayes, D.; Higinbotham, D.; Holmstrom, T.; Hyde, C. E.; Ibrahim, H.; Igarashi, R.; Jiang, X.; Jo, H. S.; Kaufman, L. J.; Kelleher, A.; Keppel, C.; Kolarkar, A.; Kuchina, E.; Kumbartzki, G.; Laveissière, G.; LeRose, J. J.; Lindgren, R.; Liyanage, N.; Lu, H.-J.; Margaziotis, D. J.; Mazouz, M.; Meziani, Z.-E.; McCormick, K.; Michaels, R.; Michel, B.; Moffit, B.; Monaghan, P.; Muñoz Camacho, C.; Nanda, S.; Nelyubin, V.; Paremuzyan, R.; Potokar, M.; Qiang, Y.; Ransome, R. D.; Réal, J.-S.; Reitz, B.; Roblin, Y.; Roche, J.; Sabatié, F.; Saha, A.; Sirca, S.; Slifer, K.; Solvignon, P.; Subedi, R.; Sulkosky, V.; Ulmer, P. E.; Voutier, E.; Wang, K.; Weinstein, L. B.; Wojtsekhowski, B.; Zheng, X.; Zhu, L.; Jefferson Lab Hall A Collaboration

    2015-11-01

    We present final results on the photon electroproduction (e ⃗p →e p γ ) cross section in the deeply virtual Compton scattering (DVCS) regime and the valence quark region from Jefferson Lab experiment E00-110. Results from an analysis of a subset of these data were published before, but the analysis has been improved, which is described here at length, together with details on the experimental setup. Furthermore, additional data have been analyzed, resulting in photon electroproduction cross sections at new kinematic settings for a total of 588 experimental bins. Results of the Q2 and xB dependencies of both the helicity-dependent and the helicity-independent cross sections are discussed. The Q2 dependence illustrates the dominance of the twist-2 handbag amplitude in the kinematics of the experiment, as previously noted. Thanks to the excellent accuracy of this high-luminosity experiment, it becomes clear that the unpolarized cross section shows a significant deviation from the Bethe-Heitler process in our kinematics, compatible with a large contribution from the leading twist-2 DVCS2 term to the photon electroproduction cross section. The necessity to include higher-twist corrections to fully reproduce the shape of the data is also discussed. The DVCS cross sections in this paper represent the final set of experimental results from E00-110, superseding the previous publication.

  15. Single and double spin asymmetries for deeply virtual Compton scattering measured with CLAS and a longitudinally polarized proton target

    SciTech Connect

    Pisano, S.; Biselli, A.; Niccolai, S.; Seder, E.; Guidal, M.; Mirazita, M.; Adhikari, K. P.; Adikaram, D.; Amaryan, M. J.; Anderson, M. D.; Anefalos Pereira, S.; Avakian, H.; Ball, J.; Battaglieri, M.; Batourine, V.; Bedlinskiy, I.; Bosted, P.; Briscoe, B.; Brock, J.; Brooks, W. K.; Burkert, V. D.; Carlin, C.; Carman, D. S.; Celentano, A.; Chandavar, S.; Charles, G.; Colaneri, L.; Cole, P. L.; Compton, N.; Contalbrigo, M.; Cortes, O.; Crabb, D. G.; Crede, V.; D' Angelo, A.; De Vita, R.; De Sanctis, E.; Deur, A.; Djalali, C.; Dupre, R.; Egiyan, H.; El Alaoui, A.; El Fassi, L.; Elouadrhiri, L.; Eugenio, P.; Fedotov, G.; Fegan, S.; Fersch, R.; Filippi, A.; Fleming, J. A.; Fradi, A.; Garillon, B.; Garcon, M.; Ghandilyan, Y.; Gilfoyle, G. P.; Giovanetti, K. L.; Girod, F. X.; Goetz, J. T.; Gohn, W.; Golovatch, E.; Gothe, R. W.; Griffioen, K. A.; Guo, L.; Hafidi, K.; Hanretty, C.; Hattawy, M.; Hicks, K.; Holtrop, M.; Hughes, S. M.; Ilieva, Y.; Ireland, D. G.; Ishkhanov, B. S.; Jenkins, D.; Jiang, X.; Jo, H. S.; Joo, K.; Joosten, S.; Keith, C. D.; Keller, D.; Kim, A.; Kim, W.; Klein, F. J.; Kubarovsky, V.; Kuhn, S. E.; Lenisa, P.; Livingston, K.; Lu, H. Y.; MacCormick, M.; MacGregor, Ian J. D.; Mayer, M.; McKinnon, B.; Meekins, D. G.; Meyer, C. A.; Mokeev, V.; Montgomery, R. A.; Moody, C. I.; Munoz Camacho, C.; Nadel-Turonski, P.; Osipenko, M.; Ostrovidov, A. I.; Park, K.; Phelps, W.; Phillips, J. J.; Pogorelko, O.; Price, J. W.; Procureur, S.; Prok, Y.; Puckett, A. J. R.; Ripani, M.; Rizzo, A.; Rosner, G.; Rossi, P.; Roy, P.; Sabatie, F.; Salgado, C.; Schott, D.; Schumacher, R. A.; Skorodumina, I.; Smith, G. D.; Sober, D. I.; Sokhan, D.; Sparveris, N.; Stepanyan, S.; Stoler, P.; Strauch, S.; Sytnik, V.; Tian, Ye; Tkachenko, S.; Turisini, M.; Ungaro, M.; Voutier, E.; Walford, N. K.; Watts, D. P.; Wei, X.; Weinstein, L. B.; Wood, M. H.; Zachariou, N.; Zana, L.; Zhang, J.; Zhao, Z. W.; Zonta, I.

    2015-03-19

    Single-beam, single-target, and double-spin asymmetries for hard exclusive photon production on the proton e→p→e'p'γ are presented. The data were taken at Jefferson Lab using the CLAS detector and a longitudinally polarized 14NH3 target. The three asymmetries were measured in 165 4-dimensional kinematic bins, covering the widest kinematic range ever explored simultaneously for beam and target-polarization observables in the valence quark region. The kinematic dependences of the obtained asymmetries are discussed and compared to the predictions of models of Generalized Parton Distributions. As a result, the measurement of three DVCS spin observables at the same kinematic points allows a quasi-model-independent extraction of the imaginary parts of the H and H~ Compton Form Factors, which give insight into the electric and axial charge distributions of valence quarks in the proton.

  16. Dispersion Representation of Deeply Virtual Compton Scattering

    NASA Astrophysics Data System (ADS)

    Pasquini, B.

    2015-09-01

    We discuss the dispersive representation of the D-term form factor for hard exclusive reactions, using unsubtracted t-channel dispersion relations. This representation provides a microscopical interpretation of the physical content of the D-term form factor in terms of t-channel exchanges with the appropriate quantum numbers. The contribution from two-pion intermediate states is explicitly evaluated, and the corresponding results for the D-term form factor as function of t as well as at t = 0 are discussed in comparison with available model predictions and phenomenological parametrizations.

  17. Deeply Virtual Pseudoscalar Meson Production with CLAS

    SciTech Connect

    Valery Kubarovsky; Paul Stoler; Ivan Bedlinsky

    2007-09-03

    Deeply virtual Compton scattering, cross sections and asymmetries for the pi^0 and eta exclusive electroproduction in a very wide kinematic range of Q^2, t and x_B have been measured with CLAS (Jlab). Initial analyzes already are showing remarkable results. These data will help us to better understand the transition from soft to hard mechanisms.

  18. Deeply Virtual Compton Scattering at HERA and perspectives at CERN

    SciTech Connect

    Schoeffel, Laurent

    2008-10-13

    Standard parton distribution functions contain neither information on the correlations between partons nor on their transverse motion, then a vital knowledge about the three dimensional structure of the nucleon is lost. Hard exclusive processes, in particular DVCS, are essential reactions to go beyond this standard picture. In the following, we examine the most recent data in view of the dipole model predictions and their implication on the quarks/gluons imaging (tomography) of the nucleon.

  19. Timelike Compton Scattering

    SciTech Connect

    T. Horn, Y. Illieva, F. J. Klein, P. Nadel‐Turonski, R. Paremuzyan, S. Stepanyan

    2011-10-01

    Generalized Parton Distributions (GPDs) have become a key concept in our studies of hadron structure in QCD. The measurement of suitable experimental observables and the extraction of GPDs from these data is one of the high priority 12 GeV programs at Jefferson Lab. Deeply Virtual Compton Scattering (DVCS) is generally thought of as the most promising channel for probing GPDs in the valence quark region. However, the inverse process, Timelike Compton Scattering (TCS) can provide an important complementary measurement, in particular of the real part of the Compton amplitude and power corrections at intermediate values of Q2. The first studies of TCS using real tagged and quasi-real untagged photons were performed in Hall B at Jefferson Lab.

  20. Shadowing in Compton scattering on nuclei

    SciTech Connect

    Kopeliovich, B. Z.; Schmidt, Ivan; Siddikov, M.

    2010-05-01

    We evaluate the shadowing effect in deeply virtual and real Compton scattering on nuclei in the framework of the color dipole model. We rely on the soft photon wave function derived in the instanton vacuum model and employ the impact parameter dependent phenomenological elastic dipole amplitude. Both the effects of quark and the gluon shadowing are taken into account.

  1. Deeply Virtual Exclusive Reactions with CLAS

    SciTech Connect

    Kubarovsky, Valery

    2011-03-01

    Deeply virtual exclusive reactions offer an unique opportunity to study the structure of the nucleon at the parton level as one has access to Bjorken xB and momentum transfer to the nucleon t at the same time. Such processes can reveal much more information about the structure of the nucleon than either inclusive electroproduction or elastic form factors alone. Dedicated experiments to study Deeply Virtual Compton Scattering (DVCS) and Deeply VirtualMeson Production (DVMP) have been carried out in Hall B at Jefferson Lab. DVCS helicity–dependent and helicity–independent cross sections and beam spin asymmetries have been measured with CLAS, as well as cross sections and asymmetries for the p 0, h, r 0, r+, w and f for exclusive electroproduction. The data were taken in a wide kinematic range in Q2=1–4.5 GeV2, xB=0.1–0.5, and |t| up to 2 GeV2. We will discuss the interpretation of these data in terms of traditional Regge and Generalized Parton Distributions models. We view the work presented in this report as leading into the program of the Jefferson Lab 12 GeV upgrade. The increased energy and luminosity will allow us to acquire data at much higher Q2 and xB, and perform Rosenbluth L/T separations of the cross sections.

  2. Timelike Compton Scattering - A First Look (CLAS)

    SciTech Connect

    Pawel Nadel-Turonski

    2009-12-01

    A major goal of the 12 GeV upgrade at Jefferson Lab is to map out the Generalized Parton Distributions (GPDs) in the valence region. This is primarily done through Deeply Virtual Compton Scattering (DVCS), which provides the simplest and cleanest way of accessing the GPDs. However, the “inverse” process, Timelike Compton Scattering (TCS), can provide an important complement, in particular formeasuring the real part of the amplitude and understanding corrections at finite Q2. The first measurements of TCS have recently been carried out in Hall B at Jefferson Lab, using both tagged and untagged photon beams.

  3. Deeply Virtual Exclusive Reactions with CLAS

    SciTech Connect

    Valery Kubarovsky

    2011-11-01

    Deeply virtual exclusive reactions offer an unique opportunity to study the structure of the nucleon at the parton level as one has access to Bjorken x{sub B} and momentum transfer to the nucleon t at the same time. Such processes can reveal much more information about the structure of the nucleon than either inclusive electroproduction or elastic form factors alone. Dedicated experiments to study Deeply Virtual Compton Scattering (DVCS) and Deeply Virtual Meson Production (DVMP) have been carried out in Hall B at Jefferson Lab. DVCS helicity–dependent and helicity–independent cross sections and beam spin asymmetries have been measured with CLAS, as well as cross sections and asymmetries for the {pi}{sup }0, {eta} , {rho}{sup }0, {rho}{sup +}, {omega} and {phi} for exclusive electroproduction. The data were taken in a wide kinematic range in Q{sup 2}=1–4.5 GeV{sup 2}, x{sub B}=0.1–0.5, and {absval t} up to 2 GeV{sup 2}. We will discuss the interpretation of these data in terms of traditional Regge and Generalized Parton Distributions (GPDs) models. The successful description of the recent CLAS pseudoscalar meson exclusive production data by GPD-based model provides a unique opportunity to access the transversity GPDs. We view the work presented in this report as leading into the program of the Jefferson Lab 12 GeV upgrade. The increased energy and luminosity will allow us to acquire data at much higher Q{sup 2} and x{sub B}, and perform Rosenbluth L/T separations of the cross sections.

  4. Deeply Virtual Exclusive Processes and Generalized Parton Distributions

    SciTech Connect

    ,

    2011-06-01

    The goal of the comprehensive program in Deeply Virtual Exclusive Scattering at Jefferson Laboratory is to create transverse spatial images of quarks and gluons as a function of their longitudinal momentum fraction in the proton, the neutron, and in nuclei. These functions are the Generalized Parton Distributions (GPDs) of the target nucleus. Cross section measurements of the Deeply Virtual Compton Scattering (DVCS) reaction ep {yields} ep{gamma} in Hall A support the QCD factorization of the scattering amplitude for Q^2 {>=} 2 GeV^2. Quasi-free neutron-DVCS measurements on the Deuteron indicate sensitivity to the quark angular momentum sum rule. Fully exclusive H(e, e'p{gamma} ) measurements have been made in a wide kinematic range in CLAS with polarized beam, and with both unpolarized and longitudinally polarized targets. Existing models are qualitatively consistent with the JLab data, but there is a clear need for less constrained models. Deeply virtual vector meson production is studied in CLAS. The 12 GeV upgrade will be essential for for these channels. The {rho} and {omega} channels reactions offer the prospect of flavor sensitivity to the quark GPDs, while the {phi}-production channel is dominated by the gluon distribution.

  5. Generalized parton distributions and Deeply Virtual Compton Scattering on proton at CLAS

    SciTech Connect

    R. De Masi

    2007-12-01

    Two measurements of target and beam spin asymmetries for the reaction ep→epγ were performed with CLAS at Jefferson Laboratory. Polarized 5.7 GeV electrons were impinging on a longitudinally polarized ammonia and liquid hydrogen target respectively. These measurements are sensitive to Generalized Parton Distributions. Sizable sin phi azimuthal angular dependences were observed in both experiments, indicating the dominance of leading twist terms and the possibility of extracting combinations of Generalized Parton Distributions on the nucleon.

  6. Towards a fitting procedure to deeply virtual meson production - the next-to-leading order case

    NASA Astrophysics Data System (ADS)

    Müller, D.; Lautenschlager, T.; Passek-Kumerički, K.; Schäfer, A.

    2014-07-01

    Based on the collinear factorization approach, we present a comprehensive perturbative next-to-leading (NLO) analysis of deeply virtual meson production (DVMP). Our representation in conformal Mellin space can serve as basis for a global fitting procedure to access generalized parton distributions from experimental measurements of DVMP and deeply virtual Compton scattering (DVCS). We introduce a rather general formalism for the evaluation of conformal moments that can be developed further beyond the considered order. We also confirm previous diagrammatical findings in the pure singlet quark channel. Finally, we use the analytic properties of the hard scattering amplitudes to estimate qualitatively the size of radiative corrections and illustrate these considerations with some numerical examples. The results suggest that global NLO GPD fits, including both DVMP and DVCS data, could be more stable than often feared.

  7. Compton scattering overview

    SciTech Connect

    Hartemann, F V

    2008-12-01

    An overview of linear and nonlinear Compton scattering is presented, along with a comparison with Thomson scattering. Two distinct processes play important roles in the nonlinear regime: multi-photon interactions, leading to the generation of harmonics, and radiation pressure, yielding a downshift of the radiated spectral features. These mechanisms, their influence on the source brightness, and different modeling strategies are also briefly discussed.

  8. Nucleon Compton Scattering

    SciTech Connect

    Bogdan Wojtsekhowski

    2006-06-04

    Review of Nucleon Compton Scattering in wide angle regime is presented. JLab experimental data strongly support dominance of handbag mechanism in the RCS process. The approved ALLRCS experiment with polarized target and future plans with 12 GeV beam are discussed.

  9. Virtual Compton Scattering

    SciTech Connect

    Helene Fonvieille

    2003-05-01

    Virtual Compton Scattering off the proton: {gamma}^+p --> {gamma}p is a new field of investigation of nucleon structure. Several dedicated experiments have been performed at low c.m. energy and various momentum transfers, yielding specific information on the proton. This talk reviews the concept of nucleon Generalized Polarizabilities and the present experimental status.

  10. Timelike Virtual Compton Scattering from Electron-Positron Radiative Annihilation

    SciTech Connect

    Afanasev, Andrei; Brodsky, Stanley J.; Carlson, Carl E.; Mukherjee, Asmita; /Indian Inst. Tech., Mumbai

    2009-03-31

    We propose measurements of the deeply virtual Compton amplitude (DVCS) {gamma}* {yields} H{bar H}{gamma} in the timelike t = (p{sub H} + p{sub {bar H}}){sup 2} > 0 kinematic domain which is accessible at electron-positron colliders via the radiative annihilation process e{sup +}e{sup -} {yields} H{bar H}{gamma}. These processes allow the measurement of timelike deeply virtual Compton scattering for a variety of H{bar H} hadron pairs such as {pi}{sup +}{pi}{sup -}, K{sup +}K{sup -}, and D{bar D} as well as p{bar p}. As in the conventional spacelike DVCS, there are interfering coherent amplitudes contributing to the timelike processes involving C = - form factors. The interference between the amplitudes measures the phase of the C = + timelike DVCS amplitude relative to the phase of the timelike form factors and can be isolated by considering the forward-backward e{sup +} {leftrightarrow} e{sup -} asymmetry. The J = 0 fixed pole contribution which arises from the local coupling of the two photons to the quark current plays a special role. As an example we present a simple model.

  11. Timelike Virtual Compton Scattering from Electron-Positron Radiative Annihilation

    SciTech Connect

    Andrei Afanaciev,Andrei Afanasev, Stanley J. Brodsky, Carl E. Carlson, Asmita Mukherjee

    2010-02-01

    We propose measurements of the deeply virtual Compton amplitude (DVCS), gamma* to H H-bar gamma, in the timelike t = (p_{H} + p_{H-bar})^2 > 0 kinematic domain which is accessible at electron-positron colliders via the radiative annihilation process e+ e- to H H-bar gamma. These processes allow the measurement of timelike deeply virtual Compton scattering for a variety of H H-bar hadron pairs such as pi+ pi-, K+ K-, and D D-bar as well as p p-bar. As in the conventional spacelike DVCS, there are interfering coherent amplitudes contributing to the timelike processes involving C= - form factors. The interference between the amplitudes measures the phase of the C=+ timelike DVCS amplitude relative to the phase of the timelike form factors and can be isolated by considering the forward-backward e+ \\leftrightarrow e- asymmetry. The J=0 fixed pole contribution which arises from the local coupling of the two photons to the quark current plays a special role. As an example we present a simple model.

  12. The Spring 2016 Deeply Virtual Compton Scattering (DVCS) Run (E12-06-114) in Hall A of TJNAF

    NASA Astrophysics Data System (ADS)

    Dlamini, Mongi

    2016-03-01

    The DVCS experiment in Hall A of the Thomas Jefferson National Accelerator Facility will provide high precision data necessary to map out the 3D structure of the nucleon in the Generalized Parton Distribution (GPD) framework. GPDs are a new class of light-cone matrix elements which encode the transverse momentum and spatial distribution of partons as a function of the longitudinal momentum of the nucleon. DVCS off the nucleon (γ*N --> γN) is the cleanest process that can access GPDs. The Hall A DVCS experiment is set to run in the Spring of 2016 using a polarized electron beam with energy ranging from 8 to 11 GeV, allowing an extended kinematic range coverage. This experiment will measure both polarized and unpolarized cross sections of the H(e,e' γ)p and H(e,e'π0)p reactions and hence probe proton GPDs. The run will complete Q2 scans at xBj ranging from 0.36 to 0.60. The Q2-dependent cross sections allow the separation of the leading-twist GPD amplitude from the higher-twist scaling-violating terms. In this talk, the status of the experiment will be presented. JLab HAll A DVCS Collaboration, JLab Hall A Collaboration.

  13. Compton scattering and generalized polarizabilities

    SciTech Connect

    Scherer, S.

    2005-05-06

    In recent years, real and virtual Compton scattering off the nucleon have attracted considerable interest from both the experimental and theoretical sides. Real Compton scattering gives access to the so-called electromagnetic polarizabilities containing the structure information beyond the global properties of the nucleon such as its charge, mass, and magnetic moment. These polarizabilities have an intuitive interpretation in terms of induced dipole moments and thus characterize the response of the constituents of the nucleon to a soft external stimulus. The virtual Compton scattering reaction e- p {yields} e- p{gamma} allows one to map out the local response to external fields and can be described in terms of generalized electromagnetic polarizabilities. A simple classical interpretation in terms of the induced electric and magnetic polarization densities is proposed. We will discuss experimental results for the polarizabilities of the proton and compare them with theoretical predictions.

  14. Local Two-Photon Couplings and the J=0 Fixed Pole in Real and Virtual Compton Scattering

    SciTech Connect

    Brodsky, Stanley J.; Llanes-Estrada, Felipe J.; Szczepaniak, Adam P.

    2008-12-05

    The local coupling of two photons to the fundamental quark currents of a hadron gives an energy-independent contribution to the Compton amplitude proportional to the charge squared of the struck quark, a contribution which has no analog in hadron scattering reactions. We show that this local contribution has a real phase and is universal, giving the same contribution for real or virtual Compton scattering for any photon virtuality and skewness at fixed momentum transfer squared t. The t-dependence of this J = 0 fixed Regge pole is parameterized by a yet unmeasured even charge-conjugation form factor of the target nucleon. The t = 0 limit gives an important constraint on the dependence of the nucleon mass on the quark mass through the Weisberger relation. We discuss how this 1=x form factor can be extracted from high energy deeply virtual Compton scattering and examine predictions given by models of the H generalized parton distribution.

  15. Spin Degrees of Freedom in Compton Scattering

    NASA Astrophysics Data System (ADS)

    Miskimen, R.

    2016-02-01

    The next generation of Compton scattering experiments is underway at Mainz and other laboratories, where the goal is precision measurements of the scalar and vector polarizabilities of the nucleon using polarized photons and polarized targets. Results are presented for the first double polarized Compton scattering experiment utilizing a polarized proton target. Preliminary results are presented for the four spin polarizabilities of the proton.

  16. Real Compton scattering via color dipoles

    SciTech Connect

    Kopeliovich, B. Z.; Schmidt, Ivan; Siddikov, M.

    2009-09-01

    We study the photoabsorption reaction and real Compton scattering within the color dipole model. We rely on a photon wave function derived in the instanton-vacuum model and on the energy-dependent phenomenological elastic dipole amplitude. Data for the photoabsorption cross section at high energies agree with our parameter-free calculations. We also provide predictions for the differential real Compton scattering cross section. Although no data for small angle Compton scattering are available so far, this process can be measured in ultraperipheral hadronic and nuclear collisions at the LHC.

  17. Compton scattering with low intensity radioactive sources

    NASA Astrophysics Data System (ADS)

    Quarles, Carroll

    2012-03-01

    Compton scattering experiments with gamma rays typically require a ``hot'' source (˜5mCi of Cs137) to observe the scattering as a function of angle. (See Ortec AN34 Experiment #10 Compton Scattering) Here a way is described to investigate Compton scattering with micro Curie level radioactive sources that are more commonly available in the undergraduate laboratory. A vertical-looking 2 inch coaxial hpGe detector, collimated with a 2 inch thick lead shield, was used. Cylindrical Al targets of various thicknesses were placed over the collimator and several available sources were placed around the target so that the average Compton scattering angle into the collimator was 90 deg. A peak could be observed at the expected energy for 90 deg. Compton scattering by doing 24 hour target-in minus target-out runs. The peak was broadened by the spread in the scattering angle due to the variation in the angle of the incoming gamma ray and the angular acceptance of the collimator. A rough analysis can be done by modeling the angular spread due to the geometry and correcting for the gamma ray absorption from the target center. Various target materials and sources can be used and some variation in average Compton scattering angle can be obtained by adjusting the geometry of the source and target.

  18. A Compton scatter attenuation gamma ray spectrometer

    NASA Technical Reports Server (NTRS)

    Austin, W. E.

    1972-01-01

    A Compton scatter attenuation gamma ray spectrometer conceptual design is discussed for performing gamma spectral measurements in monodirectional gamma fields from 100 R per hour to 1,000,000 R per hour. Selectable Compton targets are used to scatter gamma photons onto an otherwise heavily shielded detector with changeable scattering efficiencies such that the count rate is maintained between 500 and 10,000 per second. Use of two sum-Compton coincident detectors, one for energies up to 1.5 MeV and the other for 600 keV to 10 MeV, will allow good peak to tail pulse height ratios to be obtained over the entire spectrum and reduces the neutron recoil background rate.

  19. Neutron Compton scattering from selectively deuterated acetanilide

    NASA Astrophysics Data System (ADS)

    Wanderlingh, U. N.; Fielding, A. L.; Middendorf, H. D.

    With the aim of developing the application of neutron Compton scattering (NCS) to molecular systems of biophysical interest, we are using the Compton spectrometer EVS at ISIS to characterize the momentum distribution of protons in peptide groups. In this contribution we present NCS measurements of the recoil peak (Compton profile) due to the amide proton in otherwise fully deuterated acetanilide (ACN), a widely studied model system for H-bonding and energy transfer in biomolecules. We obtain values for the average width of the potential well of the amide proton and its mean kinetic energy. Deviations from the Gaussian form of the Compton profile, analyzed on the basis of an expansion due to Sears, provide data relating to the Laplacian of the proton potential.

  20. Compton Scattering Experiments with Polychromatic Radiation

    NASA Astrophysics Data System (ADS)

    Schütz, Wolfgang; Waldeck, Beate; Flösch, Dietmar; Weyrich, Wolf

    1993-02-01

    We show an iterative algorithm that allows to obtain accurate Compton profiles J(q) from Compton scattering spectra I2 (ω2), if the excitation radiation is not strictly monochromatic. It requires knowledge of the spectral distribution of the primary radiation I1(ω1), validity of the impulse approximation and dominance of a monochromatic part in I1(ω1) over the polychromatic rest. Conversely, the primary spectrum is often experimentally not directly accessible. In such a situation it is possible to evaluate the primary spectrum I1(ω1) from the spectrum of scattered photons, I2(ω2), with a similar iterative algorithm. We use a scattering target of high atomic number in order to ensure that the elastically scattered photons dominate the inelastically scattered ones. From the scattered spectrum we get a model for the Compton profile that allows us to separate the inelastic part of the scattered spectrum from the elastic part, which, in turn, is proportional to the spectral distribution of the primary radiation.

  1. Nonlinear Brightness Optimization in Compton Scattering

    DOE PAGESBeta

    Hartemann, Fred V.; Wu, Sheldon S. Q.

    2013-07-26

    In Compton scattering light sources, a laser pulse is scattered by a relativistic electron beam to generate tunable x and gamma rays. Because of the inhomogeneous nature of the incident radiation, the relativistic Lorentz boost of the electrons is modulated by the ponderomotive force during the interaction, leading to intrinsic spectral broadening and brightness limitations. We discuss these effects, along with an optimization strategy to properly balance the laser bandwidth, diffraction, and nonlinear ponderomotive force.

  2. Nonlinear brightness optimization in compton scattering.

    PubMed

    Hartemann, Fred V; Wu, Sheldon S Q

    2013-07-26

    In Compton scattering light sources, a laser pulse is scattered by a relativistic electron beam to generate tunable x and gamma rays. Because of the inhomogeneous nature of the incident radiation, the relativistic Lorentz boost of the electrons is modulated by the ponderomotive force during the interaction, leading to intrinsic spectral broadening and brightness limitations. These effects are discussed, along with an optimization strategy to properly balance the laser bandwidth, diffraction, and nonlinear ponderomotive force. PMID:23931374

  3. Experimental confirmation of neoclassical Compton scattering theory

    SciTech Connect

    Aristov, V. V.; Yakunin, S. N.; Despotuli, A. A.

    2013-12-15

    Incoherent X-ray scattering spectra of diamond and silicon crystals recorded on the BESSY-2 electron storage ring have been analyzed. All spectral features are described well in terms of the neoclassical scattering theory without consideration for the hypotheses accepted in quantum electrodynamics. It is noted that the accepted tabular data on the intensity ratio between the Compton and Rayleigh spectral components may significantly differ from the experimental values. It is concluded that the development of the general theory (considering coherent scattering, incoherent scattering, and Bragg diffraction) must be continued.

  4. Compton scattering in strong magnetic fields

    NASA Technical Reports Server (NTRS)

    Daugherty, Joseph K.; Harding, Alice K.

    1986-01-01

    The relativistic cross section for Compton scattering by electrons in strong magnetic fields is derived. The results confirm and extend earlier work which has treated only transitions to the lowest or first excited Landau levels. For the teragauss field strengths expected in neutron star magnetospheres, the relative rates for excited state transitions are found to be significant, especially for incident photon energies several times the cyclotron frequency. Since these transitions must result in the rapid emission of one or more cyclotron photons as well as the Compton-scattered photon, the scattering process actually becomes a photon 'splitting' mechanism which acts to soften hard photon spectra, and also provides a specific mechanism for populating higher Landau levels in the electron distribution function. The results should be significant for models of gamma-ray bursters and pulsating X-ray sources.

  5. Virtual Compton Scattering: Results from Jefferson Lab

    SciTech Connect

    L. Van Hoorebeke

    2003-05-01

    Virtual Compton Scattering o013 the proton has been studied at Q 2 -values of 1:0 and 1:9 (GeV=c) 2 in Hall A at the Thomas Je013erson National Accelerator Facility (JLab). Data were taken below and above the pion production threshold as well as in the resonance region. Results obtained below pion threshold at Q 2 = 1:0 (GeV=c) 2 are presented in this paper.

  6. Timelike Compton Scattering—A First Look

    NASA Astrophysics Data System (ADS)

    Nadel-Turonski, P.; Horn, T.; Ilieva, Y.; Klein, F. J.; Paremuzyan, R.; Stepanyan, S.

    2009-12-01

    A major goal of the 12 GeV upgrade at Jefferson Lab is to map out the Generalized Parton Distributions (GPDs) in the valence region. This is primarily done through Deeply Virtual Compton Scattering (DVCS), which provides the simplest and cleanest way of accessing the GPDs. However, the "inverse" process, Timelike Compton Scattering (TCS), can provide an important complement, in particular for measuring the real part of the amplitude and understanding corrections at finite Q2. The first measurements of TCS have recently been carried out in Hall B at Jefferson Lab, using both tagged and untagged photon beams.

  7. Biophysical applications of neutron Compton scattering

    NASA Astrophysics Data System (ADS)

    Wanderlingh, U. N.; Albergamo, F.; Hayward, R. L.; Middendorf, H. D.

    Neutron Compton scattering (NCS) can be applied to measuring nuclear momentum distributions and potential parameters in molecules of biophysical interest. We discuss the analysis of NCS spectra from peptide models, focusing on the characterisation of the amide proton dynamics in terms of the width of the H-bond potential well, its Laplacian, and the mean kinetic energy of the proton. The Sears expansion is used to quantify deviations from the high-Q limit (impulse approximation), and line-shape asymmetry parameters are evaluated in terms of Hermite polynomials. Results on NCS from selectively deuterated acetanilide are used to illustrate this approach.

  8. Proton spin polarizabilities from polarized Compton scattering

    SciTech Connect

    B. Pasquini; D. Drechsel; M. Vanderhaeghen

    2007-07-01

    Polarized Compton scattering off the proton is studied within the framework of subtracted dispersion relations for photon energies up to 300 MeV. As a guideline for forthcoming experiments, we focus the attention on the role of the proton's spin polarizabilities and investigate the most favorable conditions to extract them with a minimum of model dependence. We conclude that a complete separation of the four spin polarizabilities is possible, at photon energies between threshold and the $\\Delta(1232)$ region, provided one can achieve polarization measurements with an accuracy of a few percent.

  9. Anomalous nonlinear X-ray Compton scattering

    NASA Astrophysics Data System (ADS)

    Fuchs, Matthias; Trigo, Mariano; Chen, Jian; Ghimire, Shambhu; Shwartz, Sharon; Kozina, Michael; Jiang, Mason; Henighan, Thomas; Bray, Crystal; Ndabashimiye, Georges; Bucksbaum, Philip H.; Feng, Yiping; Herrmann, Sven; Carini, Gabriella A.; Pines, Jack; Hart, Philip; Kenney, Christopher; Guillet, Serge; Boutet, Sébastien; Williams, Garth J.; Messerschmidt, Marc; Seibert, M. Marvin; Moeller, Stefan; Hastings, Jerome B.; Reis, David A.

    2015-11-01

    X-ray scattering is typically used as a weak linear atomic-scale probe of matter. At high intensities, such as produced at free-electron lasers, nonlinearities can become important, and the probe may no longer be considered weak. Here we report the observation of one of the most fundamental nonlinear X-ray-matter interactions: the concerted nonlinear Compton scattering of two identical hard X-ray photons producing a single higher-energy photon. The X-ray intensity reached 4 × 1020 W cm-2, corresponding to an electric field well above the atomic unit of strength and within almost four orders of magnitude of the quantum-electrodynamic critical field. We measure a signal from solid beryllium that scales quadratically in intensity, consistent with simultaneous non-resonant two-photon scattering from nearly-free electrons. The high-energy photons show an anomalously large redshift that is incompatible with a free-electron approximation for the ground-state electron distribution, suggesting an enhanced nonlinearity for scattering at large momentum transfer.

  10. Compton scattering vertex for massive scalar QED

    SciTech Connect

    Bashir, A.; Concha-Sanchez, Y.; Delbourgo, R.; Tejeda-Yeomans, M. E.

    2009-08-15

    We investigate the Compton scattering vertex of charged scalars and photons in scalar quantum electrodynamics (SQED). We carry out its nonperturbative construction consistent with Ward-Fradkin-Green-Takahashi identity which relates 3-point vertices to the 4-point ones. There is an undetermined part which is transverse to one or both the external photons, and needs to be evaluated through perturbation theory. We present in detail how the transverse part at the 1-loop order can be evaluated for completely general kinematics of momenta involved in covariant gauges and dimensions. This involves the calculation of genuine 4-point functions with three massive propagators, the most nontrivial integrals reported in this paper. We also discuss possible applications of our results.

  11. Compton coincidence volumetric imaging: a new x-ray volumetric imaging modality based on Compton scattering

    NASA Astrophysics Data System (ADS)

    Xu, Xiaochao

    2014-03-01

    Compton scattering is a dominant interaction during radiography and computed tomography x-ray imaging. However, the scattered photons are not used for extracting imaging information, but seriously degrade image quality. Here we introduce a new scheme that overcomes most of the problems associated with existing Compton scattering imaging schemes and allows Compton scattered photons to be effectively used for imaging. In our scheme, referred as Compton coincidence volumetric imaging (CCVI), a collimated monoenergetic x-ray beam is directed onto a thin semiconductor detector. A small portion of the photons is Compton scattered by the detector and their energy loss is detected. Some of the scattered photons intersect the imaging object, where they are Compton scattered a second time. The finally scattered photons are recorded by an areal energy resolving detector panel around the object. The two detectors work in coincidence mode. CCVI images the spatial electron density distribution in the imaging object. Similar to PET imaging, the event location can be located within a curve; therefore the imaging reconstruction algorithms are also similar to those of PET. Two statistical iterative imaging reconstruction algorithms are tested. Our study verifies the feasibility of CCVI in imaging acquisition and reconstruction. Various aspects of CCVI are discussed. If successfully implemented, it will offer a great potential for imaging dose reduction compared with x-ray CT. Furthermore, a CCVI modality will have no moving parts, which potentially offers cost reduction and faster imaging speed.

  12. Compton scattering profile for in vivo XRF techniques.

    PubMed

    Tartari, A; Baraldi, C; Felsteiner, J; Casnati, E

    1991-05-01

    The contribution from single Compton scattered photons to the background in in vivo x-ray fluorescence analysis is evaluated by taking into account the energy broadening of the scattered photons which reflects the momentum distribution of the target electrons. A general-purpose Monte Carlo evaluation of multiple scattering components, as well as accurate experimental verifications with 59.54 keV photons impinging on various targets of interest for real-life irradiation, confirm that the single Compton scattering profiles of the elements composing the biological matrix dominate the trend and amplitude of the background in the region of interest with near-backscatter configurations. Step features are likewise explained in terms of single Compton phenomenology. Other probable sources of background, such as photoelectron Bremsstrahlung and pile-up distribution, are studied both theoretically and experimentally in order to compare their amplitude and features with those of single Compton scattered photon profiles. PMID:2068224

  13. Adjoint calculations for multiple scattering of Compton and Rayleigh effects

    NASA Astrophysics Data System (ADS)

    Fernández, J. E.; Sumini, M.

    1992-08-01

    As is well known, the experimental determination of the Compton profile requires a particular geometry with a scattering angle close to π. That situation involves a narrow multiple-scattering spectrum that overlaps the Compton peak, making it difficult to analyze the different contributions to the profile. We show how the solution of the adjoint problem can help in devising more useful experimental configurations, giving, through its classical "importance" meaning, a formally clear picture of the whole problem.

  14. Inverse Compton Scattering in Mildly Relativistic Plasma

    NASA Technical Reports Server (NTRS)

    Molnar, S. M.; Birkinshaw, M.

    1998-01-01

    We investigated the effect of inverse Compton scattering in mildly relativistic static and moving plasmas with low optical depth using Monte Carlo simulations, and calculated the Sunyaev-Zel'dovich effect in the cosmic background radiation. Our semi-analytic method is based on a separation of photon diffusion in frequency and real space. We use Monte Carlo simulation to derive the intensity and frequency of the scattered photons for a monochromatic incoming radiation. The outgoing spectrum is determined by integrating over the spectrum of the incoming radiation using the intensity to determine the correct weight. This method makes it possible to study the emerging radiation as a function of frequency and direction. As a first application we have studied the effects of finite optical depth and gas infall on the Sunyaev-Zel'dovich effect (not possible with the extended Kompaneets equation) and discuss the parameter range in which the Boltzmann equation and its expansions can be used. For high temperature clusters (k(sub B)T(sub e) greater than or approximately equal to 15 keV) relativistic corrections based on a fifth order expansion of the extended Kompaneets equation seriously underestimate the Sunyaev-Zel'dovich effect at high frequencies. The contribution from plasma infall is less important for reasonable velocities. We give a convenient analytical expression for the dependence of the cross-over frequency on temperature, optical depth, and gas infall speed. Optical depth effects are often more important than relativistic corrections, and should be taken into account for high-precision work, but are smaller than the typical kinematic effect from cluster radial velocities.

  15. Deep Inelastic Scattering at the Amplitude Level

    SciTech Connect

    Brodsky, Stanley J.; /SLAC

    2005-08-04

    The deep inelastic lepton scattering and deeply virtual Compton scattering cross sections can be interpreted in terms of the fundamental wavefunctions defined by the light-front Fock expansion, thus allowing tests of QCD at the amplitude level. The AdS/CFT correspondence between gauge theory and string theory provides remarkable new insights into QCD, including a model for hadronic wavefunctions which display conformal scaling at short distances and color confinement at large distances.

  16. Nucleon Compton scattering in the Dyson-Schwinger approach

    NASA Astrophysics Data System (ADS)

    Eichmann, Gernot; Fischer, Christian S.

    2013-02-01

    We analyze the nucleon’s Compton scattering amplitude in the Dyson-Schwinger/Faddeev approach. We calculate a subset of diagrams that implements the nonperturbative handbag contribution as well as all t-channel resonances. At the quark level, these ingredients are represented by the quark Compton vertex whose analytic properties we study in detail. We derive a general form for a fermion two-photon vertex that is consistent with its Ward-Takahashi identities and free of kinematic singularities, and we relate its transverse part to the on-shell nucleon Compton amplitude. We solve an inhomogeneous Bethe-Salpeter equation for the quark Compton vertex in rainbow-ladder truncation and implement it in the nucleon Compton scattering amplitude. The remaining ingredients are the dressed quark propagator and the nucleon’s bound-state amplitude which are consistently solved from Dyson-Schwinger and covariant Faddeev equations. We verify numerically that the resulting quark Compton vertex and nucleon Compton amplitude both reproduce the πγγ transition form factor when the pion pole in the t channel is approached.

  17. Enhancement of Compton scattering by an effective coupling constant

    SciTech Connect

    Barbiellini, Bernardo; Nicolini, Piero

    2011-08-15

    A robust thermodynamic argument shows that a small reduction of the effective coupling constant {alpha} of QED greatly enhances the low-energy Compton-scattering cross section and that the Thomson scattering length is connected to a fundamental scale {lambda}. A discussion provides a possible quantum interpretation of this enormous sensitivity to changes in the effective coupling constant {alpha}.

  18. Compton Scattering from Bulk and Surface of Water

    NASA Astrophysics Data System (ADS)

    Wang, Wenjie; Kuzmenko, Ivan; Vaknin, David

    2014-03-01

    Elastic and Compton scattering at grazing angle X-ray incidence from water show distinct behaviors below and above the critical angle for total reflections suggesting surface restructuring of the water surface. Using X-ray synchrotron radiation in reflectivity mode, we collect the Thomson and Compton scattering signals with energy dispersive detector at various angles near the normal to surface as a function of the angle of incidence. Analysis of the ratio between the Thomson and Compton intensity above the critical angle (which mainly probes bulk water) is a constant as expected from incoherent scattering from single water molecule, whereas the signal from the surface shows strong angular dependence on the incident angle. Although we do not fully understand the phenomena, we attribute the observation to more organized water at the interface. Ames Laboratory, DOE under contract No. DE-AC02-07CH11358 and Advanced Photon Source, DOE under contract No. DE-AC02-06CH11357.

  19. Compton-like polariton scattering in hyperbolic metamaterials.

    PubMed

    Iorsh, Ivan V; Poddubny, Alexander N; Ginzburg, Pavel; Belov, Pavel A; Kivshar, Yuri S

    2015-05-01

    We study the scattering of polaritons by free electrons in hyperbolic photonic media and demonstrate that the unconventional dispersion and high local density of states of electromagnetic modes in composite media with hyperbolic dispersion can lead to a giant Compton-like shift and dramatic enhancement of the scattering cross section. We develop a universal approach to study multiphoton processes in nanostructured media and derive the intensity spectrum of the scattered radiation for realistic metamaterial structures. PMID:26001008

  20. Spin and orbital magnetization loops obtained using magnetic Compton scattering

    SciTech Connect

    Itou, M.; Sakurai, Y.; Koizumi, A.

    2013-02-25

    We present an application of magnetic Compton scattering (MCS) to decompose a total magnetization loop into spin and orbital magnetization contributions. A spin magnetization loop of SmAl{sub 2} was measured by recording the intensity of magnetic Compton scattering as a function of applied magnetic field. Comparing the spin magnetization loop with the total magnetization one measured by a vibrating sample magnetometer, the orbital magnetization loop was obtained. The data display an anti-coupled behavior between the spin and orbital magnetizations and confirm that the orbital part dominates the magnetization.

  1. Compton scattering by a pion and off-shell effects

    SciTech Connect

    Scherer, S.; Fearing, H.W. )

    1995-01-01

    We consider Compton scattering by a pion in the framework of chiral perturbation theory. We investigate off-shell effects in the [ital s]- and [ital u]-channel pole diagrams. For that purpose we perform a field transformation which, in comparison with the standard Gasser and Leutwyler Lagrangian, generates additional terms at order [ital p][sup 4] proportional to the lowest-order equation of motion. As a result of the equivalence theorem the two Lagrangians predict the same Compton scattering [ital S]-matrix even though they generate different off-shell form factors. We conclude that off-shell effects are not only model dependent but also representation dependent.

  2. Compton scatter imaging: A tool for historical exploration.

    PubMed

    Harding, G; Harding, E

    2010-06-01

    This review discusses the principles and technological realisation of a technique, termed Compton scatter imaging (CSI), which is based on spatially resolved detection of Compton scattered X-rays. The applicational focus of this review is to objects of historical interest. Following a historical survey of CSI, a description is given of the major characteristics of Compton X-ray scatter. In particular back-scattered X-rays allow massive objects to be imaged, which would otherwise be too absorbing for the conventional transmission X-ray technique. The ComScan (an acronym for Compton scatter scanner) is a commercially available backscatter imaging system, which is discussed here in some detail. ComScan images from some artefacts of historical interest, namely a fresco, an Egyptian mummy and a mediaeval clasp are presented and their use in historical analysis is indicated. The utility of scientific and technical advance for not only exploring history, but also restoring it, is briefly discussed. PMID:20138773

  3. Inclusive and Exclusive Compton Processes in Quantum Chromodynamics

    SciTech Connect

    Ales Psaker

    2005-12-31

    In our work, we describe two types of Compton processes. As an example of an inclusive process, we consider the high-energy photoproduction of massive muon pairs off the nucleon. We analyze the process in the framework of the QCD parton model, in which the usual parton distributions emerge as a tool to describe the nucleon in terms of quark and gluonic degrees of freedom. To study its exclusive version, a new class of phenomenological functions is required, namely, generalized parton distributions. They can be considered as a generalization of the usual parton distributions measured in deeply inelastic lepton-nucleon scattering. Generalized parton distributions (GPDs) may be observed in hard exclusive reactions such as deeply virtual Compton scattering. We develop an extension of this particular process into the weak interaction sector. We also investigate a possible application of the GPD formalism to wide-angle real Compton scattering.

  4. Inverse Compton Scattering from Laser Accelerated Quasi-Monoenergetic Electrons

    NASA Astrophysics Data System (ADS)

    Mori, Yoshitaka; Kuwabara, Hajime; Ishii, Katsuhiro; Hanayama, Ryohei; Kawashima, Toshiyuki; Kitagawa, Yoneyoshi

    2010-11-01

    The progress of the laser accelerator shows us the possible applications to the industries, such as an inspection source for soft materials like as human bodies, plants foods and medicines. The inverse Compton scattering will realize such a novel inspection system. We demonstrate for the fist time that the laser-accelerated mono-energetic electrons inversely scatter the same counter laser beam to the Compton X-ray emissions. A Ti:sapphire laser (500mJ width 150fs) is divided into two beams. Main beam is focused to an edge of a helium gasjet to accelerate electrons to 13 and 22 MeV monoenergies, which inversely scattered the counter laser beam into 6 and 11 keV X-ray emissions in agreement with that calculated from the obtained electron spectra. The scattering is within 30 deg. around the main beam direction.

  5. The electromagnetic calorimeter in JLab Real Compton Scattering Experiment

    SciTech Connect

    Albert Shahinyan; Eugene Chudakov; A. Danagoulian; P. Degtyarenko; K. Egiyan; V. Gorbenko; J. Hines; E. Hovhannisyan; Ch. Hyde; C.W. de Jager; A. Ketikyan; V. Mamyan; R. Michaels; A.M. Nathan; V. Nelyubin; I. Rachek; M. Roedelbrom; A. Petrosyan; R. Pomatsalyuk; V. Popov; J. Segal; Yu. Shestakov; J. Templon; H. Voskanyan; B. Wojtsekhowski

    2007-04-16

    A hodoscope calorimeter comprising of 704 lead-glass blocks is described. The calorimeter was constructed for use in the JLab Real Compton Scattering experiment. The detector provides a measurement of the coordinates and the energy of scattered photons in the GeV energy range with resolutions of 5 mm and 6\\%/$\\sqrt{E_\\gamma \\, [GeV]}$, respectively. Design features and performance parameters during the experiment are presented.

  6. Design of a Compton scatter based radiation tracking system

    NASA Astrophysics Data System (ADS)

    Healy, Heather

    Gamma spectroscopy is one of the most common techniques used for the detection of radiologic materials. This technology is deployed in a variety of scenarios such as emergency response, monitoring, and the recovery of lost, stolen, or otherwise unaccounted radiologic material. In most practical scenarios, it is useful to know the location of a source in relation to a detector, in addition to the classic output from gamma spectrometers such as decay rate and energy peak information. In collaboration with the Remote Sensing Laboratory (RSL) at Andrews Air Force Base, a novel detector design by RSL, which utilizes a 360° detectable range in order to increase the probability of remote detection, was investigated for the possibility to recreate source location information from Compton scattering events within the detector. A recreation of this novel detector is simulated using Geant4 to determine the optimal dimensions of sodium iodide detectors that produce the most single Compton scattering events in order to facilitate source location through the back-projection of Compton scattering angles. The optimal detector dimensions are determined by maximizing the number of single Compton scatter events and minimizing the percentage of Compton events that undergo multiple successive scatters in detectors of varying thicknesses and lengths. The optimal detector thickness was chosen to be 1.88 in, and the optimal detector length was chosen to be 4 to 4.5 in. In future projects, these optimized detectors can be used to apply suggested back-projection algorithms in order to determine the feasibility and functionality of this detector design for the purpose of radiologic source location.

  7. Generalized parton distributions from deep virtual compton scattering at CLAS

    SciTech Connect

    Guidal, M.

    2010-04-24

    Here, we have analyzed the beam spin asymmetry and the longitudinally polarized target spin asymmetry of the Deep Virtual Compton Scattering process, recently measured by the Jefferson Lab CLAS collaboration. Our aim is to extract information about the Generalized Parton Distributions of the proton. By fitting these data, in a largely model-independent procedure, we are able to extract numerical values for the two Compton Form Factors $H_{Im}$ and $\\tilde{H}_{Im}$ with uncertainties, in average, of the order of 30%.

  8. Generalized parton distributions from deep virtual compton scattering at CLAS

    DOE PAGESBeta

    Guidal, M.

    2010-04-24

    Here, we have analyzed the beam spin asymmetry and the longitudinally polarized target spin asymmetry of the Deep Virtual Compton Scattering process, recently measured by the Jefferson Lab CLAS collaboration. Our aim is to extract information about the Generalized Parton Distributions of the proton. By fitting these data, in a largely model-independent procedure, we are able to extract numerical values for the two Compton Form Factorsmore » $$H_{Im}$$ and $$\\tilde{H}_{Im}$$ with uncertainties, in average, of the order of 30%.« less

  9. A Practical Review of the Kompaneets Equation and its Application to Compton Scattering

    SciTech Connect

    D.G. Shirk

    2006-05-15

    In this study, we explore both inverse Compton and Compton scattering processes using the Chang and Cooper scheme to form a deterministic solution of the Kompaneets equation. We examine the individual terms of the Kompaneets equation and illustrate their effect on the equilibrium solution. We use two examples (a Gaussian line profile and a Planck profile) to illustrate the advective and diffusive properties of the Kompaneets operator. We also explore both inverse Compton scattering and Compton scattering, and discuss and illustrate the Bose-Einstein condensation feature of the Compton scattering spectrum.

  10. COMPACT, TUNABLE COMPTON SCATTERING GAMMA-RAY SOURCES

    SciTech Connect

    Hartemann, F V; Albert, F; Anderson, G G; Anderson, S G; Bayramian, A J; Betts, S M; Chu, T S; Cross, R R; Ebbers, C A; Fisher, S E; Gibson, D J; Ladran, A S; Marsh, R A; Messerly, M J; O'Neill, K L; Semenov, V A; Shverdin, M Y; Siders, C W; McNabb, D P; Barty, C J; Vlieks, A E; Jongewaard, E N; Tantawi, S G; Raubenheimer, T O

    2009-08-20

    Recent progress in accelerator physics and laser technology have enabled the development of a new class of gamma-ray light sources based on Compton scattering between a high-brightness, relativistic electron beam and a high intensity laser pulse produced via chirped-pulse amplification (CPA). A precision, tunable gamma-ray source driven by a compact, high-gradient X-band linac is currently under development at LLNL. High-brightness, relativistic electron bunches produced by the linac interact with a Joule-class, 10 ps laser pulse to generate tunable {gamma}-rays in the 0.5-2.5 MeV photon energy range via Compton scattering. The source will be used to excite nuclear resonance fluorescence lines in various isotopes; applications include homeland security, stockpile science and surveillance, nuclear fuel assay, and waste imaging and assay. The source design, key parameters, and current status are presented.

  11. Precise polarization measurements via detection of compton scattered electrons

    SciTech Connect

    Tvaskis, Vladas; Dutta, Dipangkar; Gaskell, David J.; Narayan, Amrendra

    2014-01-01

    The Qweak experiment at Jefferson Lab aims to make a 4% measurement of the parity-violating asymmetry in elastic scattering at very low Q{sup 2} of a longitudinally polarized electron beam off a proton target. One of the dominant experimental systematic uncertainties in Qweak will result from determining the beam polarization. A new Compton polarimeter was installed in the fall of 2010 to provide a non-invasive and continuous monitoring of the electron beam polarization in Hall C at Jefferson Lab. The Compton-scattered electrons are detected in four planes of diamond micro-strip detectors. We have achieved the design goals of <1% statistical uncertainty per hour and expect to achieve <1% systematic uncertainty.

  12. Comparison between electron and neutron Compton scattering studies

    NASA Astrophysics Data System (ADS)

    Moreh, Raymond; Finkelstein, Yacov; Vos, Maarten

    2015-05-01

    We compare two techniques: Electron Compton Scattering (ECS) and neutron Compton scattering (NCS) and show that using certain incident energies, both can measure the atomic kinetic energy of atoms in molecules and solids. The information obtained is related to the Doppler broadening of nuclear levels and is very useful for deducing the widths of excited levels in many nuclei in self absorption measurements. A comparison between the atomic kinetic energies measured by the two methods on the same samples is made. Some results are also compared with calculated atomic kinetic energies obtained using the harmonic approximation where the vibrational frequencies were taken from IR/Raman optical measurements. The advantages of the ECS method are emphasized.

  13. Low-Intensity Nonlinear Spectral Effects in Compton Scattering

    SciTech Connect

    Hartemann, F V; Albert, F; Siders, C W; Barty, C P

    2010-02-23

    Nonlinear effects are known to occur in Compton scattering light sources, when the laser normalized 4-potential, A = e{radical}-A{sub {mu}}A{sup {mu}}/m{sub 0}c approaches unity. In this letter, it is shown that nonlinear spectral features can appear at arbitrarily low values of A, if the fractional bandwidth of the laser pulse, {Delta}{phi}{sup -1}, is sufficiently small to satisfy A{sup 2} {Delta}{phi} {approx_equal} 1. A three dimensional analysis, based on a local plane-wave, slow-varying envelope approximation, enables the study of these effects for realistic interactions between an electron beam and a laser pulse, and their influence on high-precision Compton scattering light sources.

  14. Detection of detachments and inhomogeneities in frescos by Compton scattering

    NASA Astrophysics Data System (ADS)

    Castellano, A.; Cesareo, R.; Buccolieri, G.; Donativi, M.; Palamà, F.; Quarta, S.; De Nunzio, G.; Brunetti, A.; Marabelli, M.; Santamaria, U.

    2005-07-01

    A mobile instrument has been developed for the detection and mapping of detachments in frescos by using Compton back scattered photons. The instrument is mainly composed of a high energy X-ray tube, an X-ray detection system and a translation table. The instrument was first applied to samples simulating various detachment situations, and then transferred to the Vatican Museum to detect detachments and inhomogeneities in the stanza di Eliodoro, one of the "Raphael's stanze".

  15. Resonant Compton scattering and gamma-ray burst continuum spectra

    NASA Technical Reports Server (NTRS)

    Baring, M. G.

    1995-01-01

    The Thomson limit of resonant inverse Compton scattering in the strong magnetic fields of neutron stars is considered as a mechanism for producing gamma-ray burst continuum spectra. Photon production spectra and electron cooling rates are presented using the full magnetic Thomson cross-section. Model emission spectra are obtained as self-consistent solutions of a set of photon and electron kinetic equations, displaying spectral breaks and other structure at gamma-ray energies.

  16. Non-linear Compton Scattering in Short Laser Pulses

    NASA Astrophysics Data System (ADS)

    Krajewska, Katarzyna; Kamiński, Jerzy

    2012-06-01

    The generation of short X-ray laser pulses attracts a great deal of attention. One of mechanisms to achieve this goal is the non-linear Compton scattering at very high laser powers. The majority of previous works on the non-linear Compton scattering have been devoted to the case when the incident laser field is treated as a monochromatic plane wave. There is, however, recent interest in analyzing the effect of a pulsed laser field on the non-linear Compton scattering [1-4]. We study the process for different durations of the incident laser pulse and compare it with the results for both a plane wave laser field and a laser pulse train. [4pt] [1] M. Boca and V. Florescu, Phys. Rev. A 80, 053403 (2009).[0pt] [2] M. Boca and V. Florescu, Eur. Phys. J. D 61, 446 (2011).[0pt] [3] D. Seipt and B. Kämpfer, Phys. Rev. A 83, 022101 (2011).[0pt] [4] F. Mackenroth and A. Di Piazza, Phys. Rev. A 83, 032106 (2011).

  17. Compton scattering off elementary spin (3/2) particles

    SciTech Connect

    Delgado-Acosta, E. G.; Napsuciale, M.

    2009-09-01

    We calculate Compton scattering off an elementary spin (3/2) particle in a recently proposed framework for the description of high spin fields based on the projection onto eigensubspaces of the Casimir operators of the Poincare group. We also calculate this process in the conventional Rarita-Schwinger formalism. Both formalisms yield the correct Thomson limit but the predictions for the angular distribution and total cross section differ beyond this point. We point out that the average squared amplitudes in the forward direction for Compton scattering off targets with spin s=0, (1/2), 1 are energy independent and have the common value 4e{sup 4}. As a consequence, in the rest frame of the particle the differential cross section for Compton scattering in the forward direction is energy independent and coincides with the classical squared radius. We show that these properties are also satisfied by a spin (3/2) target in the Poincare projector formalism but not by the Rarita-Schwinger spin (3/2) particle.

  18. SPECT Compton-scattering correction by analysis of energy spectra.

    PubMed

    Koral, K F; Wang, X Q; Rogers, W L; Clinthorne, N H; Wang, X H

    1988-02-01

    The hypothesis that energy spectra at individual spatial locations in single photon emission computed tomographic projection images can be analyzed to separate the Compton-scattered component from the unscattered component is tested indirectly. An axially symmetric phantom consisting of a cylinder with a sphere is imaged with either the cylinder or the sphere containing 99mTc. An iterative peak-erosion algorithm and a fitting algorithm are given and employed to analyze the acquired spectra. Adequate separation into an unscattered component and a Compton-scattered component is judged on the basis of filtered-backprojection reconstruction of corrected projections. In the reconstructions, attenuation correction is based on the known geometry and the total attenuation cross section for water. An independent test of the accuracy of separation is not made. For both algorithms, reconstructed slices for the cold-sphere, hot-surround phantom have the correct shape as confirmed by simulation results that take into account the measured dependence of system resolution on depth. For the inverse phantom, a hot sphere in a cold surround, quantitative results with the fitting algorithm are accurate but with a particular number of iterations of the erosion algorithm are less good. (A greater number of iterations would improve the 26% error with the algorithm, however.) These preliminary results encourage us to believe that a method for correcting for Compton-scattering in a wide variety of objects can be found, thus helping to achieve quantitative SPECT. PMID:3258023

  19. Materials characterization in petroleum pipeline using Compton Scattering technique

    NASA Astrophysics Data System (ADS)

    Gouveia, M. A. G.; Lopes, R. T.; de Jesus, E. F. O.; Camerini, C. S.

    2003-06-01

    In this paper Compton Scattering technique is analyzed as a possible tool for the characterization of materials inside draining petroleum pipelines. The study was accomplished in laboratory scale, so the results should be analyzed to conclude if the system could be used in the field. The system used was composed of two detectors aligned by a Ce-137 source forming an angle of 90° with the detectors line (662 keV—direct beam, and 288 keV—scattered beam). The results obtained show the capability of the system for the characterization of materials like sand, paraffin and water inside pipelines.

  20. Polarisation Transfer in Proton Compton Scattering at High Momentum Transfer

    SciTech Connect

    Hamilton, David

    2004-12-31

    The Jefferson Lab Hall A experiment E99-114 comprised a series of measurements to explore proton Compton scattering at high momentum transfer. For the first time, the polarisation transfer observables in the p (~ 0 ~ p) reaction were measured in the GeV energy range, where it is believed that quark-gluon degrees of freedom begin to dominate. The experiment utilised a circularly polarised photon beam incident on a liquid hydrogen target, with the scattered photon and recoil proton detected in a lead-glass calorimeter and a magnetic spectrometer, respectively.

  1. The role of Compton scattering in scinti-mammography

    SciTech Connect

    Pani, R.; Scopinaro, F.; Pergola, A.

    1996-12-31

    Functional breast imaging using {sup 99m}Tc MIBI is showing that this technique is able to detect cancer with more than 90% specificity. Using a dedicated gamma camera, with the breast under compression, i.e. in similar conditions of mammography, the detection of sub-centimeter cancers can be improved. A number of factors affects the detection of small cancers as: thickness of the breast, distance between tumor and collimator, cardiac activity. Radioactivity emitted from the body can obscure the breast activity mainly due to the large difference on radioactivity concentration. In this work we analyze the intensity and the energy distribution of Compton scattering coming from the breast by a Germanium detector and by a dedicated imager with a small FOV placed in a geometrical condition similar to mammography. In vivo measurements were performed in patients with a breast cancer ranging between 8 mm and 15 mm. Intensity of Compton scattering from 4 to 10 times greater than full energy peak events resulted. Measurements were compared with ones obtained by a phantom simulating the breast without chest activity demonstrating how large is the Compton contribution from the chest.

  2. Gamma-ray burst polarization via Compton scattering process

    SciTech Connect

    Chang, Zhe; Lin, Hai-Nan; Jiang, Yunguo

    2014-03-01

    Synchrotron radiation and Compton scattering are widely accepted as the most likely emission mechanisms of some astrophysical phenomena, such as gamma-ray bursts (GRBs) and active galactic nuclei. The measurement of the polarization of photons provides a useful tool to distinguish different emission mechanisms and structures of the emission region. Based on the differential cross section of a polarized photon scattered by an unpolarized electron of any initial momentum, we derive an analytical formula of polarization for beamed photons scattered by isotropic electrons with a power-law distribution. Numerical calculations are carried out in four special cases: electrons at rest, Thomson limit, head-on collision, and monochromatic electrons. It is found that the maximum polarization can be as high as 100% for low energy photons, if the electrons are at rest. Although polarization is highly suppressed due to the isotropic electrons, a maximum value of ∼10%-20% can still be achieved. The Compton scattering process can be used to explain the polarization of GRB 041219A and GRB 100826A.

  3. Gamma-Ray Burst Polarization via Compton Scattering Process

    NASA Astrophysics Data System (ADS)

    Chang, Zhe; Lin, Hai-Nan; Jiang, Yunguo

    2014-03-01

    Synchrotron radiation and Compton scattering are widely accepted as the most likely emission mechanisms of some astrophysical phenomena, such as gamma-ray bursts (GRBs) and active galactic nuclei. The measurement of the polarization of photons provides a useful tool to distinguish different emission mechanisms and structures of the emission region. Based on the differential cross section of a polarized photon scattered by an unpolarized electron of any initial momentum, we derive an analytical formula of polarization for beamed photons scattered by isotropic electrons with a power-law distribution. Numerical calculations are carried out in four special cases: electrons at rest, Thomson limit, head-on collision, and monochromatic electrons. It is found that the maximum polarization can be as high as 100% for low energy photons, if the electrons are at rest. Although polarization is highly suppressed due to the isotropic electrons, a maximum value of ~10%-20% can still be achieved. The Compton scattering process can be used to explain the polarization of GRB 041219A and GRB 100826A.

  4. The polarization effect of a laser in multiphoton Compton scattering

    NASA Astrophysics Data System (ADS)

    Liang, Guo-Hua; Lü, Qing-Zheng; Teng, Ai-Ping; Li, Ying-Jun

    2014-05-01

    The multiphoton Compton scattering in a high-intensity laser beam is studied by using the laser-dressed quantum electrodynamics (QED) method, which is a non-perturbative theory for the interaction between a plane electromagnetic field and a charged particle. In order to analyze in the real experimental condition, a Lorentz transformation for the cross section of this process is derived between the laboratory frame and the initial rest frame of electrons. The energy of the scattered photon is analyzed, as well as the cross sections for different laser intensities and polarizations and different electron velocities. The angular distribution of the emitted photon is investigated in a special velocity of the electron, in which for a fixed number of absorbed photons, the electron energy will not change after the scattering in the lab frame. We obtain the conclusion that higher laser intensities suppress few-laser-photon absorption and enhance more-laser-photon absorption. A comparison between different polarizations is also made, and we find that the linearly polarized laser is more suitable to generate nonlinear Compton scattering.

  5. Exclusive neutral pion electroproduction in the deeply virtual regime

    SciTech Connect

    Fuchey, E.; Camsonne, A.; Bertin, P.; Munoz Camacho, C.; Gavalian, G.; Amarian, M.; Canan, M.; Hayes, D.; Ibrahim, H.; Ulmer, P. E.; Weinstein, L. B.; Kuchina, E.; Gilman, R.; Jiang, X.; Kumbartzki, G.; McCormick, K.; Ransome, R. D.; Aniol, K. A.; Margaziotis, D. J.

    2011-02-15

    We present measurements of the ep{yields}ep{pi}{sup 0} cross section extracted at two values of four-momentum transfer Q{sup 2}=1.9 GeV{sup 2} and Q{sup 2}=2.3 GeV{sup 2} at Jefferson Lab Hall A. The kinematic range allows one to study the evolution of the extracted cross section as a function of Q{sup 2} and W. Results are confronted with Regge-inspired calculations and GPD predictions. An intepretation of our data within the framework of semi-inclusive deep inelastic scattering is also discussed.

  6. Exclusive Neutral Pion Electroproduction in the Deeply Virtual Regime

    SciTech Connect

    Fuchey, E; Camsonne, A; Mazouz, M; Gavalian, G; Kuchina, E; Amarian, M; Aniol, K A; Beaumel, M; Benaoum, H; Bertin, P; Brossard, M; Canan, M; Chen, J -P; Chudakov, E; Craver, B; Cusanno, F; de Jager, C W; Deur, A; Ferdi, C; Feuerbach, R; Fieschi, J -M; Frullani, S; Garcon, M; Garibaldi, F; Gayou, O; Gilman, R; Gomez, J; Gueye, P; Guichon, P.A.M.; Guillon, B; Hansen, O; Hayes, D; Higinbotham, D W; Homstrom, T; Hyde, C E; Ibrahim, H; Igarashi, R; Itard, F; Jiang, X; Jo, H S; Kaufman, L J; Kelleher, A; Kolarkar, A; Kumbartzki, G; Laveissiere, G; LeRose, J J; Lindgren, R; Liyanage, N; Lu, H -J; Margaziotis, D J; Meziani, Z -E; McCormick, K; Michaels, R; Michel, B; Moffit, B; Monaghan, P; Nanda, S; Nelyubin, V; Potokar, M; Qiang, Y; Ransome, R D; Real, J -S; Reitz, B; Roblin, Y; Roche, J; Sabatie, F; Saha, A; Sirca, S; Slifer, K; Solvignon, P; Subedi, R; Sulkosky, V; Ulmer, P E; Voutier, E; Wang, K; Weinstein, L B; Wojtsekhowski, B; Zheng, X; Zhu, L

    2011-02-01

    We present measurements of the ep->ep pi^0 cross section extracted at two values of four-momentum transfer Q^2=1.9 GeV^2 and Q^2=2.3 GeV^2 at Jefferson Lab Hall A. The kinematic range allows to study the evolution of the extracted hadronic tensor as a function of Q^2 and W. Results will be confronted with Regge inspired calculations and GPD predictions. An intepretation of our data within the framework of semi-inclusive deep inelastic scattering has also been attempted.

  7. Densitometry and temperature measurement of combustion gas by X-ray Compton scattering

    PubMed Central

    Sakurai, Hiroshi; Kawahara, Nobuyuki; Itou, Masayoshi; Tomita, Eiji; Suzuki, Kosuke; Sakurai, Yoshiharu

    2016-01-01

    Measurement of combustion gas by high-energy X-ray Compton scattering is reported. The intensity of Compton-scattered X-rays has shown a position dependence across the flame of the combustion gas, allowing us to estimate the temperature distribution of the combustion flame. The energy spectra of Compton-scattered X-rays have revealed a significant difference across the combustion reaction zone, which enables us to detect the combustion reaction. These results demonstrate that high-energy X-ray Compton scattering can be employed as an in situ technique to probe inside a combustion reaction. PMID:26917151

  8. Densitometry and temperature measurement of combustion gas by X-ray Compton scattering.

    PubMed

    Sakurai, Hiroshi; Kawahara, Nobuyuki; Itou, Masayoshi; Tomita, Eiji; Suzuki, Kosuke; Sakurai, Yoshiharu

    2016-03-01

    Measurement of combustion gas by high-energy X-ray Compton scattering is reported. The intensity of Compton-scattered X-rays has shown a position dependence across the flame of the combustion gas, allowing us to estimate the temperature distribution of the combustion flame. The energy spectra of Compton-scattered X-rays have revealed a significant difference across the combustion reaction zone, which enables us to detect the combustion reaction. These results demonstrate that high-energy X-ray Compton scattering can be employed as an in situ technique to probe inside a combustion reaction. PMID:26917151

  9. Non-thermal shielding effects on the Compton scattering power in astrophysical plasmas

    NASA Astrophysics Data System (ADS)

    Shin, Dong-Soo; Jung, Young-Dae

    2015-10-01

    The non-thermal shielding effects on the inverse Compton scattering are investigated in astrophysical non-thermal Lorentzian plasmas. The inverse Compton power is obtained by the modified Compton scattering cross section in Lorentzian plasmas with the blackbody photon distribution. The total Compton power is also obtained by the Lorentzan distribution of plasmas. It is found that the influence of non-thermal character of the plasma suppresses the inverse Compton power in astrophysical Lorentzian plasmas. It is also found that the non-thermal effect on the inverse Compton power decreases with an increase of the temperature. In addition, the non-thermal effect on the total Compton power with Lorentzan plasmas increases in low-temperature photons and, however, decreases in intermediate-temperature photons with increasing Debye length. The variation of the total Compton power is also discussed.

  10. Virtual Compton scattering off the nucleon at low energies

    SciTech Connect

    Scherer, S.; Korchin, A.Y.; Koch, J.H.

    1996-08-01

    We investigate the low-energy behavior of the four-point Green{close_quote}s function {Gamma}{sup {mu}{nu}} describing virtual Compton scattering off the nucleon. Using Lorentz invariance, gauge invariance, and crossing symmetry, we derive the leading terms of an expansion of the operator in the four-momenta {ital q} and {ital q}{sup {prime}} of the initial and final photon, respectively. The model-independent result is expressed in terms of the electromagnetic form factors of the free nucleon, i.e., on-shell information which one obtains from electron-nucleon scattering experiments. Model-dependent terms appear in the operator at {ital O}({ital q}{sub {alpha}}{ital q}{sub {beta}}{sup {prime}}), whereas the orders {ital O}({ital q}{sub {alpha}}{ital q}{sub {beta}}) and {ital O}({ital q}{sub {alpha}}{sup {prime}}{ital q}{sub {beta}}{sup {prime}}) are contained in the low-energy theorem for {Gamma}{sup {mu}{nu}}, i.e., no new parameters appear. We discuss the leading terms of the matrix element and comment on the use of on-shell equivalent electromagnetic vertices in the calculation of {open_quote}{open_quote}Born terms{close_quote}{close_quote} for virtual Compton scattering. {copyright} {ital 1996 The American Physical Society.}

  11. Radiative corrections to real and virtual muon Compton scattering revisited

    NASA Astrophysics Data System (ADS)

    Kaiser, N.

    2010-06-01

    We calculate in closed analytical form the one-photon loop radiative corrections to muon Compton scattering μγ→μγ. Ultraviolet and infrared divergences are both treated in dimensional regularization. Infrared finiteness of the (virtual) radiative corrections is achieved (in the standard way) by including soft photon radiation below an energy cut-off λ. We find that the anomalous magnetic moment α/2π provides only a very small portion of the full radiative corrections. Furthermore, we extend our calculation of radiative corrections to the muon-nucleus bremsstrahlung process (or virtual muon Compton scattering μγ0∗→μγ). These results are particularly relevant for analyzing the COMPASS experiment at CERN in which muon-nucleus bremsstrahlung serves to calibrate the Primakoff scattering of high-energy pions off a heavy nucleus with the aim of measuring the pion electric and magnetic polarizabilities. We find agreement with an earlier calculation of these radiative corrections based on a different method.

  12. Polarization Transfer in Proton Compton Scattering at High Momentum Transfer

    SciTech Connect

    Hamilton, D.J.; Annand, J.R.M.; Mamyan, V.H.; Aniol, K.A.; Margaziotis, D.J.; Bertin, P.Y.; Camsonne, A.; Laveissiere, G.; Bosted, P.; Paschke, K.; Calarco, J.R.; Chang, G.C.; Horn, T.; Savvinov, N.; Chang, T.-H.; Danagoulian, A.; Nathan, A.M.; Roedelbronn, M.; Chen, J.-P.

    2005-06-24

    Compton scattering from the proton was investigated at s=6.9 GeV{sup 2} and t=-4.0 GeV{sup 2} via polarization transfer from circularly polarized incident photons. The longitudinal and transverse components of the recoil proton polarization were measured. The results are in disagreement with a prediction of perturbative QCD based on a two-gluon exchange mechanism, but agree well with a prediction based on a reaction mechanism in which the photon interacts with a single quark carrying the spin of the proton.

  13. Nonlinear single Compton scattering of an electron wave packet

    NASA Astrophysics Data System (ADS)

    Angioi, A.; Mackenroth, F.; Di Piazza, A.

    2016-05-01

    Nonlinear single Compton scattering has been thoroughly investigated in the literature under the assumption that the electron initially has a definite momentum. Here, we study a more general initial state and consider the electron as a wave packet. In particular, we investigate the energy spectrum of the emitted radiation and show that, in typical experimental situations, some features of the spectra shown in previous works are almost completely washed out. Moreover, we show that, at comparable relative uncertainties, the one in the momentum of the incoming electron has a larger impact on the photon spectra at a fixed observation direction than the one on the laser frequency.

  14. Transition-radiation-Compton-scattering detector for very relativistic nuclei

    NASA Technical Reports Server (NTRS)

    Osborne, W. Z.; Mack, J. E.

    1975-01-01

    The paper presents the design and predicted performance of a large acceptance (2 sq m sr) transition-radiation-Compton-scattering detector system which can be used to measure energy spectra up to several thousand Gev/nucleon for nuclei with Z between 6 and 28, as well as up to 40,000 GeV/nucleon for He. The following circumstances made such a detector system practicable: (1) transition radiation output is proportional to the square of particle charge; (2) output varies at least as rapidly as the square of Lorentz factor over the range from several hundred to several thousand.

  15. Polarization Transfer in Proton Compton Scattering at High Momentum Transfer

    SciTech Connect

    D.J. Hamilton; Vahe Mamyan

    2004-10-01

    Compton scattering from the proton was investigated at s = 6.9 GeV{sup 2} and t = -4.0 TeV{sup 2} via polarization transfer from circularly polarized incident photons. The longitudinal and transverse components of the recoil proton polarization were measured. The results are in excellent agreement with a prediction based on a reaction mechanism in which the photon interacts with a single quark carrying the spin of the proton and in disagreement with a prediction of pQCD based on a two-gluon exchange mechanism.

  16. Magnetic properties of Ga doped cobalt ferrite: Compton scattering study

    SciTech Connect

    Sharma, Arvind Mund, H. S.; Ahuja, B. L.; Sahariya, Jagrati; Itou, M.; Sakurai, Y.

    2014-04-24

    We present the spin momentum density of Ga doped CoFe{sub 2}O{sub 4} at 100 K using magnetic Compton scattering. The measurement has been performed using circularly polarized synchrotron radiations of 182.65 keV at SPring8, Japan. The experimental profile is decomposed into its constituent profile to determine the spin moment at individual sites. Co atom has the maximum contribution (about 58%) in the total spin moment of the doped CoFe{sub 2}O{sub 4}.

  17. Quantum Radiation Reaction Effects in Multiphoton Compton Scattering

    SciTech Connect

    Di Piazza, A.; Hatsagortsyan, K. Z.; Keitel, C. H.

    2010-11-26

    Radiation reaction effects in the interaction of an electron and a strong laser field are investigated in the realm of quantum electrodynamics. We identify the quantum radiation reaction with the multiple photon recoils experienced by the laser-driven electron due to consecutive incoherent photon emissions. After determining a quantum radiation dominated regime, we demonstrate how in this regime quantum signatures of the radiation reaction strongly affect multiphoton Compton scattering spectra and that they could be measurable in principle with presently available laser technology.

  18. Resonant inverse Compton scattering by secondary pulsar plasma

    NASA Astrophysics Data System (ADS)

    Lyubarskii, Yu. E.; Petrova, S. A.

    Neutron stars are known to be rather hot, the temterature scaling a few times 105K. Thermal X-ray photons emitted by the star surface suffer inverse Compton scattering off the particles of pulsar plasma. In the presence of a strong magnetic field the scattering cross-section is essentially enhanced if the photon energy in the particle rest frame equals the cyclotron energy. At typical pulsar conditions the photons near the maximum of the neutron star black-body spectrum are resonantly scattered by the particles with the Lorentz-factors γ ~102 - 103. So resonant inverse Compton scattering is the most efficient for the secondary plasma particles, being an essential energy-loss mechanism in a wide range of pulsar parameters. For the resonant character of the scattering the energy loss depends essentially on the initial particle energy. Since the distribution function of the secondary plasma is broad (γ ~10 - 104), it evolves essentially. The particles with the Lorentz-factors ~102 - 103 are substantially decelerated forming a sharp peak at low energies. The particles at the wings of the initial distribution are not decelerated at all. Thus, the resultant distribution function of the secondary plasma becomes two-humped giving rise to the two-stream instability. The growth rate for the instability is found to be sufficiently high at typical conditions. So the two-stream instability develops readily and leads to an essential increase of plasma oscillations which are likely to be transformed into radio emission. The resonantly upscattered photons are found to gain energies of 1-10 MeV, so that they form an additional component in pulsar gamma-ray spectrum. The corresponding gamma-ray flux is estimated as well.

  19. Nucleon polarizabilities: From Compton scattering to hydrogen atom

    NASA Astrophysics Data System (ADS)

    Hagelstein, Franziska; Miskimen, Rory; Pascalutsa, Vladimir

    2016-05-01

    We review the current state of knowledge of the nucleon polarizabilities and of their role in nucleon Compton scattering and in hydrogen spectrum. We discuss the basic concepts, the recent lattice QCD calculations and advances in chiral effective-field theory. On the experimental side, we review the ongoing programs aimed to measure the nucleon (scalar and spin) polarizabilities via the Compton scattering processes, with real and virtual photons. A great part of the review is devoted to the general constraints based on unitarity, causality, discrete and continuous symmetries, which result in model-independent relations involving nucleon polarizabilities. We (re-)derive a variety of such relations and discuss their empirical value. The proton polarizability effects are presently the major sources of uncertainty in the assessment of the muonic hydrogen Lamb shift and hyperfine structure. Recent calculations of these effects are reviewed here in the context of the "proton-radius puzzle". We conclude with summary plots of the recent results and prospects for the near-future work.

  20. Compton scatter with polychromatic sources for lung densitometry.

    PubMed

    Hanson, J A; Moore, W E; Figley, M M; Duke, P R

    1984-01-01

    A mobile lung densitometer using conventional x-ray tubes, NaI detectors, and principles of two-source, two-detector Compton scattered densitometry, is described. The device is capable of one to two per second density measurements from a 45-cm3 volume with a precision of 5%. The expected in vivo accuracy (2%-3%) is determined by using an anthropomorphic phantom with replaceable lung inserts. The unintentional detection of multiple-scattered x rays results in a small density-dependent error. This error is predictable and relatively insensitive to differences in surrounding absorbers such as the chest wall. With this device, dynamic in vivo densitometry of the lung in the clinical laboratory and intensive care unit will be possible. PMID:6503878

  1. Beam normal spin asymmetry in the quasireal Compton scattering approximation

    SciTech Connect

    Gorchtein, M.

    2006-05-15

    The two-photon exchange contribution to the single spin asymmetries with the spin orientation normal to the reaction plane is discussed for elastic electron-proton scattering in the equivalent photon approximation. In this case, the hadronic part of the two-photon exchange amplitude describes real Compton scattering (RCS). We show that in the case of the beam normal spin asymmetry this approximation selects only the photon helicity flip amplitudes of RCS. At low energies, we make use of unitarity and estimate the contribution of the {pi}N multipoles to the photon helicity flip amplitudes. In the Regge regime, the quasi-RCS (QRCS) approximation allows for a contribution from two-pion exchange, and we provide an estimate of such contributions.

  2. Compton scattering from nuclei and photo-absorption sum rules

    NASA Astrophysics Data System (ADS)

    Gorchtein, Mikhail; Hobbs, Timothy; Londergan, J. Timothy; Szczepaniak, Adam P.

    2011-12-01

    We revisit the photo-absorption sum rule for real Compton scattering from the proton and from nuclear targets. In analogy with the Thomas-Reiche-Kuhn sum rule appropriate at low energies, we propose a new “constituent quark model” sum rule that relates the integrated strength of hadronic resonances to the scattering amplitude on constituent quarks. We study the constituent quark model sum rule for several nuclear targets. In addition, we extract the α=0 pole contribution for both proton and nuclei. Using the modern high-energy proton data, we find that the α=0 pole contribution differs significantly from the Thomson term, in contrast with the original findings by Damashek and Gilman.

  3. The nonlinear effect in relativistic Compton scattering for an intense circularly polarized laser

    NASA Astrophysics Data System (ADS)

    Luo, W.; Zhuo, H. B.; Ma, Y. Y.; Zhu, Z. C.; Fan, G. T.; Xu, W.; Song, Y. M.

    2014-07-01

    Compton scattering between an intense laser pulse and a relativistic electron beam offers a promising development path toward high-energy, high-brightness x- and gamma-ray sources. Increasing laser peak power to obtain intense x- and gamma rays causes nonlinear Compton scattering to occur. To predict high-order harmonic radiation properties, we upgrade a Monte Carlo laser-Compton scattering simulation code (MCLCSS) by taking into account the nonlinear effect for the relativistic Compton scattering process. The energy spectra and angular and harmonic intensity distributions of the scattered photons are investigated using nonlinear Compton scattering of an intense circularly polarized laser. It is found that the laser parameter {{a}_{0}}\\equiv e{\\rm{A}}\\;{{m}_{e}}{{c}^{-2}} plays an important role in the generation of high-order harmonic radiation. Our study also suggests that the high-energy tails of the second and higher harmonics will stray from the backscattering region.

  4. Determination of Rest Mass Energy of the Electron by a Compton Scattering Experiment

    ERIC Educational Resources Information Center

    Prasannakumar, S.; Krishnaveni, S.; Umesh, T. K.

    2012-01-01

    We report here a simple Compton scattering experiment which may be carried out in graduate and undergraduate laboratories to determine the rest mass energy of the electron. In the present experiment, we have measured the energies of the Compton scattered gamma rays with a NaI(Tl) gamma ray spectrometer coupled to a 1 K multichannel analyzer at…

  5. Measurement of Compton scattering in phantoms by germanium detectors

    SciTech Connect

    Zasadny, K.R.; Koral, K.F. . Medical Center); Floyd, C.E. Jr.; Jaszczak, R.J. . Dept. of Radiology)

    1990-04-01

    Quantitative Anger-camera tomography requires correction for Compton scattering. The Anger camera spectral-fitting technique can measure scatter fractions at designated positions in an image allowing for correction. To permit verification of those measurements for {sup 131}I, the authors have determined scatter fractions with a high-purity germanium (HPGe) detector and various phantom configurations. The scatter fraction values for {sup 99m}Tc were also measured and are compared to results from Monte Carlo simulation. The phantom consisted of a 22.2 cm diameter {times} 18.6 cm high cylinder filled with water and a 6 cm diameter water-filled sphere placed at various locations inside the cylinder. Radioisotope is added to either the sphere or the cylinder. The source is collimated by an Anger camera collimator and the active area of the HPGe detector is defined by a 0.6 cm diameter hole in a lead shielding mask. Corrections include accounting for the HPGe detector efficiency as a function of gamma-ray energy, the finite energy resolution of detector and the HPGe detector energy resolution compared to that for a NaI(Tl) Anger camera.

  6. Observation of enhanced Compton scattering in a supercavity

    SciTech Connect

    Fujita, M.; Asakawa, M.; Chen, J.

    1995-12-31

    The enhanced Compton scattering in a supercavity has been observed experimentally. The supercavity with {approximately}99.99% reflectivity mirrors was used to confine the LD-pumped Nd:YAG laser light ({lambda} {approximately} 1.06 {mu} m, CW power {approximately} 500 mW, bandwidth <5kHz). The confined photons were scattered by 100kV electron beams generated from the laser-heated CW electrostatic accelerator. In this experiment, the scattered photon wavelength was in a visible range (<380nm). In order to increase the beam current and the system efficiency, the design of a beam recovery system is also in progress. As an alternative way to confine the laser power, a novel multi-pass optical resonator is being designed. 9MeV electron bunch from the rf linac with photoinjector will be used to interact with MW {approximately} TW high peak power laser pulse in the resonator. In this experiment, the scattered photon energy is in a x-ray regime. These experimental data is used to design the monochromatic {gamma}-ray sources for annihilation of the radioactive nuclear waste.

  7. Real Compton Scattering on Proton at High Momentum Transfers

    SciTech Connect

    A. Danagoulian; D.J. Hamilton; C.E. Hyde-Wright; V.H. Mamyan; A.M. Nathan; M. Roedelbronn; B. Wojtsekhowski

    2005-06-01

    The E99-114 experiment was carried out to measure the cross sections for Real Compton Scattering (RCS) on the proton in the kinematic range s = 5-11 GeV{sup 2}, -t = 2-7 GeV{sup 2}. In addition, a measurement of longitudinal and transverse polarization transfers was made at s = 6.9 GeV{sup 2} and -t = 4.0 GeV{sup 2}. These measurements were done to test the existing theoretical mechanisms for this process and will possibly lead to the determination of RCS form factors which are related to the Generalized Parton Distributions (GPD). The experiment was conducted in Hall A of Thomas Jefferson National Accelerator Facility (Jefferson Lab). Final results of polarization transfer measurements are presented.

  8. Polarizability relations across real and virtual Compton scattering processes

    NASA Astrophysics Data System (ADS)

    Pascalutsa, Vladimir; Vanderhaeghen, Marc

    2015-03-01

    We derive two relations involving spin polarizabilities of a spin-1 /2 particle and consider their empirical implications for the proton. Using the empirical values of the proton anomalous magnetic moment, electric and magnetic charge radii, moments of the spin structure functions g1 , g2, and of two spin polarizabilities, the present relations constrain the low-momentum behavior of generalized polarizabilities appearing in virtual Compton scattering. In the case of the proton, the dispersive model evaluations of the spin and generalized polarizabilities appear to be consistent with these relations. The ongoing measurements of different electromagnetic observables at the MAMI, Jefferson Lab, and HI γ S facilities may be able to put these relations to a test, or use them to unravel the low-energy spin structure of the nucleon.

  9. Wide Angle Compton Scattering within the SCET factorization Framework

    NASA Astrophysics Data System (ADS)

    Kivel, Nikolay

    2016-03-01

    Existing data for the electromagnetic proton form factors and for the cross section of the wide angle Compton scattering (WACS) show that the hard two-gluon exchange mechanism (collinear factorization) is still not applicable in the kinematical region where Mandelstam variables s ~ -t ~ -u are about few GeV2. On the other hand these observables can be described in phenomenological models where spectator quarks are soft which assumes a large contribution due to the soft-overlap mechanism. It turns out that the simple QCD factorization picture is not complete and must also include the soft-overlap contribution which can be described as a certain matrix element in the soft collinear effective theory (SCET). Then the leading power contribution to WACS amplitude is described as a sum of the hard- and soft-spectator contributions. The existing experimental data allows one to check certain conclusions based on the assumption about dominant role of the soft-spectator mechanism.

  10. Virtual Compton scattering off the nucleon in chiral perturbation theory

    SciTech Connect

    Hemmert, T.R.; Holstein, B.R.; Knoechlein, G.; Scherer, S.

    1997-03-01

    We investigate the spin-independent part of the virtual Compton scattering (VCS) amplitude off the nucleon within the framework of chiral perturbation theory. We perform a consistent calculation to third order in external momenta according to Weinberg`s power counting. With this calculation we can determine the second- and fourth-order structure-dependent coefficients of the general low-energy expansion of the spin-averaged VCS amplitude based on gauge invariance, crossing symmetry, and the discrete symmetries. We discuss the kinematical regime to which our calculation can be applied and compare our expansion with the multipole expansion by Guichon, Liu, and Thomas. We establish the connection of our calculation with the generalized polarizabilities of the nucleon where it is possible. {copyright} {ital 1997} {ital The American Physical Society}

  11. Gauge invariance and Compton scattering from relativistic composite systems

    SciTech Connect

    Ito, H.; Gross, F. |

    1993-09-01

    Using the Ward-Takahashi (W-T) identity and the Bethe-Salpeter (B-S) wave equation, we investigate the dynamical requirements imposed by electromagnetic gauge invariance on Compton scattering from relativistic composite system. The importance of off-shell rescattering in intermediate states, which is equivalent to final state interactions in inclusive processes, is clarified in the context of current conservation. It is shown that, if the nuclear force is nonlocal, there will be both two-photon interaction currents and rescattering contributions to terms involving one-photon interaction currents. We derive the two-body W-T identity for the two-photon interaction currents, and obtain explicit forms for the interaction current operators for three illustrative models of nuclear forces: (a) two-pion exchange forces with baryon resonances, (b) covariant separable forces, and (c) charged one-pion exchange.

  12. Gamma ray polarimetry. [compton scattering and pair production

    NASA Technical Reports Server (NTRS)

    Long, K. S.; Novick, R.

    1978-01-01

    Spectroscopic instruments currently being proposed may possess polarimetric capabilities which sould be nurtured and enhanced to permit characterization of basic emission mechanisms which are impossible using other techniques. Compton scattering and pair production detected the polarization of high energy (E is greater than 50 keV) protons in laboratory experiments. The polarization properties of a detection system consisting of 19 germanium crystals in a closed packed array are examined and the advantages of such a detector over Thompson scattering are discussed. The possiblity of using pair production to detect polarization of high energy gamma rays, and the associated modulation factors are discussed. The central difficulty involved in using pair production polarimeters in astrophysical applications is that the typical opening of the electron or positron direction with respect to the incident photon aircitron is small, of order E/sq mc. Multiple scattering in the material used to convert the photons to an electron positron pair causes deviations in the direction of the electron and positron.

  13. High-energy Picosecond Laser Pulse Recirculation for Compton Scattering

    SciTech Connect

    Jovanovic, I; Anderson, S G; Betts, S M; Brown, C; Gibson, D J; Hartemann, F V; Hernandez, J E; Johnson, M; McNabb, D P; Messerly, M; Pruet, J; Shverdin, M Y; Siders, C W; Tremaine, A M; Barty, C J

    2007-06-12

    Frequency upconversion of laser-generated photons by inverse Compton scattering for applications such as nuclear spectroscopy and gamma-gamma collider concepts on the future ILC would benefit from an increase of average source brightness. The primary obstacle to higher average brightness is the relatively small Thomson scattering cross section. It has been proposed that this limitation can be partially overcome by use of laser pulse recirculation. The traditional approach to laser recirculation entails resonant coupling of low-energy pulse train to a cavity through a partially reflective mirror. Here we present an alternative, passive approach that is akin to 'burst-mode' operation and does not require interferometric alignment accuracy. Injection of a short and energetic laser pulse is achieved by placing a thin frequency converter, such as a nonlinear optical crystal, into the cavity in the path of the incident laser pulse. This method leads to the increase of x-ray/gamma-ray energy proportional to the increase in photon energy in frequency conversion. Furthermore, frequency tunability can be achieved by utilizing parametric amplifier in place of the frequency converter.

  14. Beam-shape effects in nonlinear Compton and Thomson scattering

    SciTech Connect

    Heinzl, T.; Seipt, D.; Kaempfer, B.

    2010-02-15

    We discuss intensity effects in collisions between beams of optical photons from a high-power laser and relativistic electrons. Our main focus is on the modifications of the emission spectra due to realistic finite-beam geometries. By carefully analyzing the classical limit we precisely quantify the distinction between strong-field QED Compton scattering and classical Thomson scattering. A purely classical, but fully covariant, calculation of the bremsstrahlung emitted by an electron in a plane-wave laser field yields radiation into harmonics, as expected. This result is generalized to pulses of finite duration and explains the appearance of line broadening and harmonic substructure as an interference phenomenon. The ensuing numerical treatment confirms that strong focusing of the laser leads to a broad continuum while higher harmonics become visible only at moderate focusing, and hence lower intensity. We present a scaling law for the backscattered photon spectral density which facilitates averaging over electron beam phase space. Finally, we propose a set of realistic parameters such that the observation of intensity-induced spectral red shift, higher harmonics, and their substructure becomes feasible.

  15. Resonant Compton Scattering in Highly-Magnetized Pulsars

    NASA Astrophysics Data System (ADS)

    Wadiasingh, Zorawar

    Soft gamma repeaters and anomalous X-ray pulsars are subset of slow-rotating neutron stars, known as magnetars, that have extremely high inferred surface magnetic fields, of the order 100-1000 TeraGauss. Hard, non-thermal and pulsed persistent X-ray emission extending between 10 keV and 230 keV has been seen in a number of magnetars by RXTE, INTEGRAL, and Suzaku. In this thesis, the author considers inner magnetospheric models of such persistent hard X-ray emission where resonant Compton upscattering of soft thermal photons is anticipated to be the most efficient radiative process. This high efficiency is due to the relative proximity of the surface thermal photons, and also because the scattering becomes resonant at the cyclotron frequency. At the cyclotron resonance, the effective cross section exceeds the classical Thomson one by over two orders of magnitude, thereby enhancing the efficiency of continuum production and cooling of relativistic electrons. In this thesis, a new Sokolov and Ternov formulation of the QED Compton scattering cross section for strong magnetic fields is employed in electron cooling and emission spectra calculations. This formalism is formally correct for treating spin-dependent effects and decay rates that are important at the cyclotron resonance. The author presents electron cooling rates at arbitrary interaction points in a magnetosphere using the QED cross sections. The QED effects reduce the rates below high-field extrapolations of older magnetic Thomson results. The author also computes angle-dependent upscattering model spectra, formed using collisional integrals, for uncooled monoenergetic relativistic electrons injected in inner regions of pulsar magnetospheres. These spectra are integrated over closed field lines and obtained for different observing perspectives. The spectral cut-off energies are critically dependent on the observer viewing angles and electron Lorentz factor. It is found that electrons with energies less than

  16. Compton scattering and nucleon polarisabilities in chiral EFT: Status and future

    NASA Astrophysics Data System (ADS)

    Grießhammer, Harald W.; McGovern, Judith A.; Phillips, Daniel R.

    2016-05-01

    We review theoretical progress and prospects for determining the nucleon's static dipole polarisabilities from Compton scattering on few-nucleon targets, including new values; see Refs. [1-5] for details and a more thorough bibliography.

  17. News on Compton Scattering γX → γX in Chiral EFT

    NASA Astrophysics Data System (ADS)

    Grießhammer, Harald W.; McGovern, Judith A.; Phillips, Daniel R.

    2016-03-01

    We review theoretical progress and prospects to understand the nucleon's static dipole polarisabilities from Compton scattering on few-nucleon targets, including new values; see Refs. [1-5] for details and a more thorough bibliography.

  18. Initial State Helicity Correlation in Wide Angle Compton Scattering

    NASA Astrophysics Data System (ADS)

    Day, Donal; Keller, Dustin; Zhang, Jixie

    2015-04-01

    Whether pQCD can describe exclusive reactions at medium energies remains an area of active study. Real Compton scattering (RCS) has the potential to provide insight to this unsettled issue. A pQCD description of RCS requires the participation of three quarks and two hard gluons. However its predictions for the RCS cross sections disagree with data while calculations based on the handbag mechanism, involving a single quark coupled to the spectator through generalized parton distributions (GPDs), match the data well. The measured longitudinal polarization transfer parameter KLL is inconsistent with predictions of pQCD yet consistent with calculations of the handbag mechanism. Furthermore, Miller's approach, which includes quark and hadron helicity flip, contradicts pQCD where KLL =ALL , the initial state helicity correlation asymmetry, by finding that KLL ≠ALL . The first ever measurement of ALL (E12-14-006) has been approved to run in Jefferson Lab's Hall C and will be able to discriminate between the various models. E12-14-006 will utilize an untagged bremsstrahlung photon beam and the longitudinally polarized UVA/JLAB proton target. After a brief introduction to the physics, the experiment will be described and the expected results presented.

  19. Preliminary observation of nonlinear effects in Compton scattering

    SciTech Connect

    Bula, C.; McDonald, K.T.; Prebys, E.J.; E-144 Collaboration

    1996-07-01

    In a new experiment at the Final Focus Test Beam at SLAC a low- emittance 46.6 GeV electron beam is brought into collision with terawatt pulses from a 1.06 {mu} wavelength Nd:glass laser. Peak laser intensities of 10{sup 18} W/cm{sup 2} have been achieved corresponding to a value of 0.6 for the parameter {eta} = {ital eE/mw{sub 0}c}, and to a value of 0.3 for the parameter {Upsilon} = {ital E{sup *}/E{sub crit}} = 2{gamma}{ital ehE}/{ital m}{sup 2}{ital c}{sup 3} in the case of frequency doubled laser pulses. In these circumstances an electron that crosses the center of the laser pulse has near unit interaction probability. Signals are presented for multiphoton Compton scattering in which up to 4 laser photons interact with an electron. High energy backscattered photons of GeV energy can interact within the laser focus to create electron- positron pairs; an excess of 15 positrons above a background of 14 was observed in a run of 6,000 laser shots.

  20. Proton Spin Polarizabilities with Polarized Compton Scattering at MAMI

    NASA Astrophysics Data System (ADS)

    Paudyal, Dilli; A2 Collaboration

    2015-10-01

    The nucleon polarizabilities are fundamental structure observables, which describe its response to an applied electric or magnetic field. While the electric and magnetic scalar polarizabilities of the nucleon have been measured, little effort has been made to extract the spin dependent polarizabilities. These leading order spin dependent terms of the nucleon polarizabilities, γE1E1 ,γM1M1 ,γM1E2 and γE1M2 describe the spin response of a proton to electric and magnetic dipole and quadrupole interactions. We plan to extract these spin polarizabilities of the proton using real polarised Compton scattering off the proton at the MAMI tagged photon facility in Mainz, Germany. This requires precise measurement of the single and double polarization observables which are sensitive to these polarizabilities. The double polarization observables ∑2 x, ∑2 z are measured via a circulary polarized photon beam and a transversely and a linearly polarized butanol target in the resonance region (E = 250 - 310 MeV). This presentation will be focused on the status and analyis of an experiment completed at MAMI in 2014 and 2015 for the measurement of ∑2 z at different energies and angles. Supported by the Natural Sciences and Engineering Research Council of Canada (NSERC).

  1. Initial State Helicity Correlation in Wide Angle Compton Scattering

    NASA Astrophysics Data System (ADS)

    Day, Donal; Keller, Dustin; Zhang, Jixie

    2016-03-01

    Wide-angle Compton scattering (WACS) belongs to the family of exclusive processes, with large values of s, - t , and - u , that can reveal nucleon structure. In the pQCD version of WACS, three active quarks and two hard gluons are required to share the momentum. pQCD predictions for the WACS disagree with the cross sections currently available. In contrast, handbag mechanism calculations involving a single quark coupled to the spectator through GPDs, are compatible with the cross sections. Measurements of the longitudinal polarization transfer parameter KLL have been found to be inconsistent with the predictions of pQCD yet consistent with calculations within the handbag mechanism, at least at very large angles. There are handbag calculations, including quark and hadron helicity flip, which contradicts pQCD by finding that KLL ≠ALL . A measurement of ALL has been approved to run at Jefferson Lab and which has the potential to clarify the nature of the reaction mechanism in WACS and illuminate the role of quark orbital angular momentum. It will utilize a pure untagged bremsstrahlung photon beam and a longitudinally polarized proton target. After an introduction, the experiment will be described and the expected results presented.

  2. Helium Compton Form Factor Measurements at CLAS

    SciTech Connect

    Voutier, Eric J.-M.

    2013-07-01

    The distribution of the parton content of nuclei, as encoded via the generalized parton distributions (GPDs), can be accessed via the deeply virtual Compton scattering (DVCS) process contributing to the cross section for leptoproduction of real photons. Similarly to the scattering of light by a material, DVCS provides information about the dynamics and the spatial structure of hadrons. The sensitivity of this process to the lepton beam polarization allows to single-out the DVCS amplitude in terms of Compton form factors that contain GPDs information. The beam spin asymmetry of the $^4$He($\\vec {\\mathrm e}$,e$' \\gamma ^4$He) process was measured in the experimental Hall B of the Jefferson Laboratory to extract the real and imaginary parts of the twist-2 Compton form factor of the $^4$He nucleus. The experimental results reported here demonstrate the relevance of this method for such a goal, and suggest the dominance of the Bethe-Heitler amplitude to the unpolarized process in the kinematic range explored by the experiment.

  3. Tomographic images of breast tissues obtained by Compton scattering: An analytical computational study

    NASA Astrophysics Data System (ADS)

    Antoniassi, M.; Poletti, M. E.; Brunetti, A.

    2015-11-01

    In this work, we studied by analytical simulation the potential of a Compton scatter technique for breast imaging application. A Compton scattering tomography system was computationally simulated in order to provide the projection data (scattering signal) for the image reconstructions. The simulated projections generated by the analytical proposed method were validated through comparison with those obtained by Monte Carlo simulation. Electron density images were obtained from the scattering signal using a reconstruction algorithm implemented for the system geometry. Finally, the quality of the reconstructed images was evaluated for different sample sizes, beam energies, and tissue compositions (glandularities).

  4. Compton scattering cross section for inner-shell electrons in the relativistic impulse approximation

    NASA Astrophysics Data System (ADS)

    Stutz, G. E.

    2014-01-01

    Total Compton scattering cross sections and inelastic scattering factors for bound electron states of several elements have been evaluated in the framework of the relativistic impulse approximation (RIA). The accuracy of different approximate expressions for the singly differential cross section within the RIA is discussed. Accurate evaluations of bound state scattering factors require the use of the full RIA expression. Compton scattering from K-shell electrons dominates over the photoelectric absorption at higher energies. Energy values at which the Compton interaction become the main process of creation of K-shell vacancies are assessed. The role of binding effects in Compton processes at lower energies are clearly evidenced by the computed total cross sections. Calculated K-shell ionization total cross sections, defined as the sum of the photoelectric absorption and the Compton scattering cross sections, are in good agreement with available experimental data. The total Compton cross section for the 2s atomic orbital exhibits a shoulder-like structure, which can be traced back to the node structure of the 2s wave function.

  5. Precision Measurement of Delbrück Scattering via Laser Compton Scattered γ-rays

    NASA Astrophysics Data System (ADS)

    Koga, J. K.; Hayakawa, T.

    2016-03-01

    Precision measurements such as the muon anomalous magnetic moment have indicated deviations from the standard model and have in turn prompted higher precision theoretical calculations. Delbrück scattering is the scattering of photons off the Coulomb field of nuclei via virtual electron-positron pairs and has been measured using γ-rays from radioactivities and following neutron capture reactions. However, because low flux γ-rays from nuclear transitions have been used in the low photon energy regime fairly large uncertainty exists in the data. In addition, due to the complexity and time consuming nature of the theoretical calculation the scattering cross sections are obtained from tables with interpolation between the tabular values. In recent years high flux γ-ray sources via laser Compton scattering (LCS) using energy-recovery linacs have been proposed. These sources allow measuring the Delbrück scattering with high precision. We will present our own independent calculations for the scattering cross section and show what precision can be obtained using the new LCS γ-ray sources in the low photon energy regime.

  6. A method for determination mass absorption coefficient of gamma rays by Compton scattering.

    PubMed

    El Abd, A

    2014-12-01

    A method was proposed for determination mass absorption coefficient of gamma rays for compounds, alloys and mixtures. It is based on simulating interaction processes of gamma rays with target elements having atomic numbers from Z=1 to Z=92 using the MCSHAPE software. Intensities of Compton scattered gamma rays at saturation thicknesses and at a scattering angle of 90° were calculated for incident gamma rays of different energies. The obtained results showed that the intensity of Compton scattered gamma rays at saturations and mass absorption coefficients can be described by mathematical formulas. These were used to determine mass absorption coefficients for compound, alloys and mixtures with the knowledge of their Compton scattered intensities. The method was tested by calculating mass absorption coefficients for some compounds, alloys and mixtures. There is a good agreement between obtained results and calculated ones using WinXom software. The advantages and limitations of the method were discussed. PMID:25241360

  7. Measurement of an inverse Compton scattering source local spectrum using k-edge filters

    SciTech Connect

    Golosio, Bruno; Oliva, Piernicola; Carpinelli, Massimo; Endrizzi, Marco; Delogu, Pasquale; Pogorelsky, Igor; Yakimenko, Vitaly

    2012-04-16

    X-ray sources based on the inverse Compton scattering process are attracting a growing interest among scientists, due to their extremely fast pulse, quasi-monochromatic spectrum, and relatively high intensity. The energy spectrum of the x-ray beam produced by inverse Compton scattering sources in a fixed observation direction is a quasi-monochromatic approximately Gaussian distribution. The mean value of this distribution varies with the scattering polar angle between the electron beam direction and the x-ray beam observation direction. Previous works reported experimental measurements of the mean energy as a function of the polar angle. This work introduces a method for the measurement of the whole local energy spectrum (i.e., the spectrum in a fixed observation direction) of the x-ray beam yielded by inverse Compton scattering sources, based on a k-edge filtering technique.

  8. High-Power Laser Pulse Recirculation for Inverse Compton Scattering-Produced Gamma-Rays

    SciTech Connect

    Jovanovic, I; Shverdin, M; Gibson, D; Brown, C

    2007-04-17

    Inverse Compton scattering of high-power laser pulses on relativistic electron bunches represents an attractive method for high-brightness, quasi-monoenergetic {gamma}-ray production. The efficiency of {gamma}-ray generation via inverse Compton scattering is severely constrained by the small Thomson scattering cross section. Furthermore, repetition rates of high-energy short-pulse lasers are poorly matched with those available from electron accelerators, resulting in low repetition rates for generated {gamma}-rays. Laser recirculation has been proposed as a method to address those limitations, but has been limited to only small pulse energies and peak powers. Here we propose and experimentally demonstrate an alternative method for laser pulse recirculation that is uniquely capable of recirculating short pulses with energies exceeding 1 J. Inverse Compton scattering of recirculated Joule-level laser pulses has a potential to produce unprecedented peak and average {gamma}-ray brightness in the next generation of sources.

  9. Anisotropic induced Compton scattering - Constraints on models of active galactic nuclei

    NASA Technical Reports Server (NTRS)

    Coppi, P.; Blandford, R. D.; Rees, M. J.

    1993-01-01

    A model for nonlinear radiative transfer on a lattice is used to explore observational signatures of anisotropic induced Compton scattering. Ways in which an intense beam of radiation may be altered in passing through a slab of plasma that is optically thin to spontaneous Thomson scattering are explained. A numerical approach to induced Compton scattering which involves solving the equations of nonlinear transfer on a lattice is described. Results of calculations for some simple geometrical configurations (spheres, disks, cylindrical 'jets', etc.) are presented. Some possible applications of these results to the interpretation of actual data on compact radio sources are outlined, and the FIR spectra of AGN are considered.

  10. An energy-subtraction Compton scatter camera design for in vivo medical imaging of radiopharmaceuticals

    SciTech Connect

    Rohe, R.C.; Valentine, J.D.

    1996-12-01

    A Compton scatter camera (CSC) design is proposed for imaging radioisotopes used as biotracers. A clinical version may increase sensitivity by a factor of over 100, while maintaining or improving spatial resolution, as compared with existing Anger cameras that use lead collimators. This novel approach is based on using energy subtraction ({Delta}E = E{sub 0} {minus} E{sub SC}, where E{sub 0}, {Delta}E, and E{sub SC} are the energy of the emitted gamma ray, the energy deposited by the initial Compton scatter, and the energy of the Compton scattered photon) to determine the amount of energy deposited in the primary system. The energy subtraction approach allows the requirement of high energy resolution to be placed on a secondary detector system instead of the primary detector system. Requiring primary system high energy resolution has significantly limited previous CSC designs for medical imaging applications. Furthermore, this approach is dependent on optimizing the camera design for data acquisition of gamma rays that undergo only one Compton scatter in a low-Z primary detector system followed by a total absorption of the Compton scattered photon in a high-Z secondary detector system. The proposed approach allows for a more compact primary detector system, a more simplified pulse processing interface, and a much less complicated detector cooling scheme as compared with previous CSC designs. Analytical calculations and Monte Carlo simulation results for some specific detector materials and geometries are presented.

  11. Electronic structure of lanthanum sesquioxide: A Compton scattering study

    NASA Astrophysics Data System (ADS)

    Sharma, Sonu; Sahariya, Jagrati; Arora, Gunjan; Ahuja, B. L.

    2014-10-01

    We present the first-ever experimental and theoretical momentum densities of La2O3. The Compton line shape is measured using a 20 Ci 137Cs Compton spectrometer at an intermediate resolution with full width at half maximum of 0.34 a.u. The experimental Compton profile is compared with the theoretical electron momentum densities computed using linear combination of atomic orbitals (LCAO) method with density functional theory (DFT). It is seen that the generalized gradient approximation (GGA) within DFT reconciles better with the experiment than other DFT based approximations, validating the GGA approximation for rare-earth sesquioxides. The energy bands and density of states computed using LCAO calculations show its wide band gap nature which is in tune with the available reflectivity and photo-absorption data. In addition, Mulliken's population and charge density are also computed and discussed.

  12. A Compton scattering technique to determine wood density and locating defects in it

    SciTech Connect

    Tondon, Akash Sandhu, B. S.; Singh, Bhajan; Singh, Mohinder

    2015-08-28

    A Compton scattering technique is presented to determine density and void location in the given wooden samples. The technique uses a well collimated gamma ray beam from {sup 137}Cs along with the NaI(Tl) scintillation detector. First, a linear relationship is established between Compton scattered intensity and known density of chemical compounds, and then density of the wood is determined from this linear relation. In another experiment, the ability of penetration of gamma rays is explored to detect voids in wooden (low Z) sample. The sudden reduction in the Compton scattered intensities agrees well with the position and size of voids in the wooden sample. It is concluded that wood density and the voids of size ∼ 4 mm and more can be detected easily by this method.

  13. The limitations of resonant Compton scattering as a gamma-ray burst model

    NASA Technical Reports Server (NTRS)

    Brainerd, J. J.

    1992-01-01

    Resonant Compton upscattering is commended as a mechanism that produces a hard gamma-ray spectrum while suppressing X-rays. This model, however, has severe physical and observational limitations. Effective X-ray suppression places a lower limit on the electron density; above this limit X-rays scatter multiple times, so the single-scattering approximation of this mechanism is invalid. Multiple scattering produces a spectrum that is much harder than the single-scattering spectrum. As the Thomson optical depth of a power-law electron beam approaches unity, photon spawning commences at a high rate and physically invalidates the underlying electron distribution. The Compton upscattering model is therefore only valid over a narrow range of electron densities. An observational consequence of this model is the absence of the third cyclotron resonance. Resonant scattering produces gamma-rays that propagate nearly along the magnetic field. The resonant cross section of the third harmonic, which is strongly angle dependent, falls below the Compton continuum for these gamma rays. The observation of a third cyclotron resonance in a gamma-ray burst spectrum would eliminate resonant Compton scattering as a gamma-ray burst process.

  14. Double electron ionization in Compton scattering of high energy photons by helium atoms

    SciTech Connect

    Amusia, M.Y.; Mikhailov, A.I.

    1995-08-01

    The cross section for double-electron ionization of two-electron atoms and ions in Compton scattering of high energy photons is calculated. It is demonstrated that its dependence on the incoming photon frequency is the same as that for single-electron ionization. The ratio of {open_quotes}double-to-single{close_quotes} ionization in Compton scattering was found to be energy independent and almost identical with the corresponding value for photoionization. For the He atom it is 1.68%. This surprising result deserves experimental verification.

  15. Compton Scattering X-Ray Sources Driven by Laser Wakefield Acceleration

    SciTech Connect

    Hartemann, F V; Gibson, D J; Brown, W J; Rousse, A; Phuoc, K T; Pukhov, A

    2005-10-19

    Recent laser wakefield acceleration experiments have demonstrated the generation of femtosecond, nano-Coulomb, low emittance, nearly monokinetic relativistic electron bunches of sufficient quality to produce bright, tunable, ultrafast x-rays via Compton scattering. Design parameters for a proof-of-concept experiment are presented using a three-dimensional Compton scattering code and a laser-plasma interaction particle-in-cell code modeling the wakefield acceleration process; x-ray fluxes exceeding 10{sup 22} s{sup -1} are predicted, with a peak brightness > 10{sup 20} photons/(mm{sup 2} x mrad{sup 2} x s x 0.1% bandwidth).

  16. Quality Control of Pavements and Tarmacs Using ({sup 137}Cs){gamma} Compton Scattering

    SciTech Connect

    Pino, F.; Barros, H.; Bernal, M.; Sajo-Bohus, L.; Palacios, D.; Greaves, E. D.; Viesti, G.

    2010-08-04

    The {gamma} Compton scattering over a volume of concrete has been studied in order to design an instrument for density measurements. It will be used for the quality control in road construction, where large surfaces must be monitored. The experimental results and Monte Carlo simulations of the {gamma} Compton scattering over homogeneous and inhomogeneous volumes of concrete are shown. MC simulations have been useful to optimize the values of several parameters to improve the experimental set up and to estimate the extension of the explored volume.

  17. On the line-shape analysis of Compton profiles and its application to neutron scattering

    NASA Astrophysics Data System (ADS)

    Romanelli, G.; Krzystyniak, M.

    2016-05-01

    Analytical properties of Compton profiles are used in order to simplify the analysis of neutron Compton scattering experiments. In particular, the possibility to fit the difference of Compton profiles is discussed as a way to greatly decrease the level of complexity of the data treatment, making the analysis easier, faster and more robust. In the context of the novel method proposed, two mathematical models describing the shapes of differenced Compton profiles are discussed: the simple Gaussian approximation for harmonic and isotropic local potential, and an analytical Gauss-Hermite expansion for an anharmonic or anisotropic potential. The method is applied to data collected by VESUVIO spectrometer at ISIS neutron and muon pulsed source (UK) on Copper and Aluminium samples at ambient and low temperatures.

  18. Small-angle Compton Scattering to Determine the Depth of a Radioactive Source in Matter

    SciTech Connect

    Oberer, R. B.; Gunn, C. A.; Chiang, L. G.; Valiga, R. E.; Cantrell, J. A.

    2011-04-01

    A gamma-ray peak in a spectrum is often accompanied by a discontinuity in the Compton continuum at the peak. The Compton continuum results from Compton scattering in the detector. The discontinuity at a peak results from small-angle Compton scattering by the gamma rays in matter situated directly between the gamma-ray source and the detector. The magnitude of this discontinuity with respect to the gamma-ray peak is therefore an indicator of the amount of material or shielding between the gamma-ray source and the detector. This small-angle scattering was used to determine the depth of highly-enriched uranium (HEU) solution standards in a concrete floor mockup. The empirical results of the use of this small-angle scattering discontinuity in a concrete floor experiment will be described. A Monte Carlo calculation of the experiment will also be described. In addition, the depth determined from small-angle scattering was used in conjunction with differential attenuation to more accurately measure the uranium content of the mockup. Following these empirical results, the theory of small-angle scattering will be discussed. The magnitude of the discontinuity compared to the peak count rate is directly related to the depth of the gamma-ray source in matter. This relation can be described by relatively simple mathematical expressions. This is the first instance that we are aware of in which the small-angle Compton scattering has been used to determine the depth of a radioactive source. Furthermore this is the first development of the theoretical expressions for the magnitude of the small-angle scattering discontinuity.

  19. Electronic properties and Compton scattering studies of monoclinic tungsten dioxide

    NASA Astrophysics Data System (ADS)

    Heda, N. L.; Ahuja, Ushma

    2015-01-01

    We present the first ever Compton profile measurement of WO2 using a 20 Ci 137Cs γ-ray source. The experimental data have been used to test different approximations of density functional theory in linear combination of atomic orbitals (LCAO) scheme. It is found that theoretical Compton profile deduced using generalized gradient approximation (GGA) gives a better agreement than local density approximation and second order GGA. The computed energy bands, density of states and Mulliken's populations (MP) data confirm a metal-like behavior of WO2. The electronic properties calculated using LCAO approach are also compared with those obtained using full potential linearized augmented plane wave method. The nature of bonding in WO2 is also compared with isoelectronic WX2 (X=S, Se) compounds in terms of equal-valence-electron-density profiles and MP data, which suggest an increase in ionic character in the order WSe2→WS2→WO2.

  20. Narrowband inverse Compton scattering x-ray sources at high laser intensities

    NASA Astrophysics Data System (ADS)

    Seipt, D.; Rykovanov, S. G.; Surzhykov, A.; Fritzsche, S.

    2015-03-01

    Narrowband x- and γ -ray sources based on the inverse Compton scattering of laser pulses suffer from a limitation of the allowed laser intensity due to the onset of nonlinear effects that increase their bandwidth. It has been suggested that laser pulses with a suitable frequency modulation could compensate this ponderomotive broadening and reduce the bandwidth of the spectral lines, which would allow one to operate narrowband Compton sources in the high-intensity regime. In this paper we therefore present the theory of nonlinear Compton scattering in a frequency-modulated intense laser pulse. We systematically derive the optimal frequency modulation of the laser pulse from the scattering matrix element of nonlinear Compton scattering, taking into account the electron spin and recoil. We show that, for some particular scattering angle, an optimized frequency modulation completely cancels the ponderomotive broadening for all harmonics of the backscattered light. We also explore how sensitively this compensation depends on the electron-beam energy spread and emittance, as well as the laser focusing.

  1. Foreign body detection in food materials using compton scattered x-rays

    NASA Astrophysics Data System (ADS)

    McFarlane, Nigel James Bruce

    This thesis investigated the application of X-ray Compton scattering to the problem of foreign body detection in food. The methods used were analytical modelling, simulation and experiment. A criterion was defined for detectability, and a model was developed for predicting the minimum time required for detection. The model was used to predict the smallest detectable cubes of air, glass, plastic and steel. Simulations and experiments were performed on voids and glass in polystyrene phantoms, water, coffee and muesli. Backscatter was used to detect bones in chicken meat. The effects of geometry and multiple scatter on contrast, signal-to-noise, and detection time were simulated. Compton scatter was compared with transmission, and the effect of inhomogeneity was modelled. Spectral shape was investigated as a means of foreign body detection. A signal-to-noise ratio of 7.4 was required for foreign body detection in food. A 0.46 cm cube of glass or a 1.19 cm cube of polystyrene were detectable in a 10 cm cube of water in one second. The minimum time to scan a whole sample varied as the 7th power of the foreign body size, and the 5th power of the sample size. Compton scatter inspection produced higher contrasts than transmission, but required longer measurement times because of the low number of photon counts. Compton scatter inspection of whole samples was very slow compared to production line speeds in the food industry. There was potential for Compton scatter in applications which did not require whole-sample scanning, such as surface inspection. There was also potential in the inspection of inhomogeneous samples. The multiple scatter fraction varied from 25% to 55% for 2 to 10 cm cubes of water, but did not have a large effect on the detection time. The spectral shape gave good contrasts and signal-to-noise ratios in the detection of chicken bones.

  2. Sensitivity booster for DOI-PET scanner by utilizing Compton scattering events between detector blocks

    NASA Astrophysics Data System (ADS)

    Yoshida, Eiji; Tashima, Hideaki; Yamaya, Taiga

    2014-11-01

    In a conventional PET scanner, coincidence events are measured with a limited energy window for detection of photoelectric events in order to reject Compton scatter events that occur in a patient, but Compton scatter events caused in detector crystals are also rejected. Scatter events within the patient causes scatter coincidences, but inter crystal scattering (ICS) events have useful information for determining an activity distribution. Some researchers have reported the feasibility of PET scanners based on a Compton camera for tracing ICS into the detector. However, these scanners require expensive semiconductor detectors for high-energy resolution. In the Anger-type block detector, single photons interacting with multiple detectors can be obtained for each interacting position and complete information can be gotten just as for photoelectric events in the single detector. ICS events in the single detector have been used to get coincidence, but single photons interacting with multiple detectors have not been used to get coincidence. In this work, we evaluated effect of sensitivity improvement using Compton kinetics in several types of DOI-PET scanners. The proposed method promises to improve the sensitivity using coincidence events of single photons interacting with multiple detectors, which are identified as the first interaction (FI). FI estimation accuracy can be improved to determine FI validity from the correlation between Compton scatter angles calculated on the coincidence line-of-response. We simulated an animal PET scanner consisting of 42 detectors. Each detector block consists of three types of scintillator crystals (LSO, GSO and GAGG). After the simulation, coincidence events are added as information for several depth-of-interaction (DOI) resolutions. From the simulation results, we concluded the proposed method promises to improve the sensitivity considerably when effective atomic number of a scintillator is low. Also, we showed that FI estimate

  3. Generation of Femtosecond X-Rays by 90 degrees Compton Scattering

    SciTech Connect

    Kim, K.-J.; Chattopadhyay, S.; Shank, C.V.

    1992-12-01

    We propose Compton scattering of a short pulse visible laser beam by a low energy (but relativistic) electron beam at a right angle for generation of femtosecond x-rays. Simple analysis to determine the qualitative and quantitative characteristics of the x-ray pulse is presented.

  4. Polarization Transfer in Wide-Angle Compton Scattering and Single-Pion Photoproduction from the Proton

    NASA Astrophysics Data System (ADS)

    Fanelli, C.; Cisbani, E.; Hamilton, D. J.; Salmé, G.; Wojtsekhowski, B.; Ahmidouch, A.; Annand, J. R. M.; Baghdasaryan, H.; Beaufait, J.; Bosted, P.; Brash, E. J.; Butuceanu, C.; Carter, P.; Christy, E.; Chudakov, E.; Danagoulian, S.; Day, D.; Degtyarenko, P.; Ent, R.; Fenker, H.; Fowler, M.; Frlez, E.; Gaskell, D.; Gilman, R.; Horn, T.; Huber, G. M.; de Jager, C. W.; Jensen, E.; Jones, M. K.; Kelleher, A.; Keppel, C.; Khandaker, M.; Kohl, M.; Kumbartzki, G.; Lassiter, S.; Li, Y.; Lindgren, R.; Lovelace, H.; Luo, W.; Mack, D.; Mamyan, V.; Margaziotis, D. J.; Markowitz, P.; Maxwell, J.; Mbianda, G.; Meekins, D.; Meziane, M.; Miller, J.; Mkrtchyan, A.; Mkrtchyan, H.; Mulholland, J.; Nelyubin, V.; Pentchev, L.; Perdrisat, C. F.; Piasetzky, E.; Prok, Y.; Puckett, A. J. R.; Punjabi, V.; Shabestari, M.; Shahinyan, A.; Slifer, K.; Smith, G.; Solvignon, P.; Subedi, R.; Wesselmann, F. R.; Wood, S.; Ye, Z.; Zheng, X.

    2015-10-01

    Wide-angle exclusive Compton scattering and single-pion photoproduction from the proton have been investigated via measurement of the polarization transfer from a circularly polarized photon beam to the recoil proton. The wide-angle Compton scattering polarization transfer was analyzed at an incident photon energy of 3.7 GeV at a proton scattering angle of θcmp=70 ° . The longitudinal transfer KLL, measured to be 0.645 ±0.059 ±0.048 , where the first error is statistical and the second is systematic, has the same sign as predicted for the reaction mechanism in which the photon interacts with a single quark carrying the spin of the proton. However, the observed value is ˜3 times larger than predicted by the generalized-parton-distribution-based calculations, which indicates a significant unknown contribution to the scattering amplitude.

  5. Polarization Transfer in Wide-Angle Compton Scattering and Single-Pion Photoproduction from the Proton.

    PubMed

    Fanelli, C; Cisbani, E; Hamilton, D J; Salmé, G; Wojtsekhowski, B; Ahmidouch, A; Annand, J R M; Baghdasaryan, H; Beaufait, J; Bosted, P; Brash, E J; Butuceanu, C; Carter, P; Christy, E; Chudakov, E; Danagoulian, S; Day, D; Degtyarenko, P; Ent, R; Fenker, H; Fowler, M; Frlez, E; Gaskell, D; Gilman, R; Horn, T; Huber, G M; de Jager, C W; Jensen, E; Jones, M K; Kelleher, A; Keppel, C; Khandaker, M; Kohl, M; Kumbartzki, G; Lassiter, S; Li, Y; Lindgren, R; Lovelace, H; Luo, W; Mack, D; Mamyan, V; Margaziotis, D J; Markowitz, P; Maxwell, J; Mbianda, G; Meekins, D; Meziane, M; Miller, J; Mkrtchyan, A; Mkrtchyan, H; Mulholland, J; Nelyubin, V; Pentchev, L; Perdrisat, C F; Piasetzky, E; Prok, Y; Puckett, A J R; Punjabi, V; Shabestari, M; Shahinyan, A; Slifer, K; Smith, G; Solvignon, P; Subedi, R; Wesselmann, F R; Wood, S; Ye, Z; Zheng, X

    2015-10-01

    Wide-angle exclusive Compton scattering and single-pion photoproduction from the proton have been investigated via measurement of the polarization transfer from a circularly polarized photon beam to the recoil proton. The wide-angle Compton scattering polarization transfer was analyzed at an incident photon energy of 3.7 GeV at a proton scattering angle of θ_{cm}^{p}=70°. The longitudinal transfer K_{LL}, measured to be 0.645±0.059±0.048, where the first error is statistical and the second is systematic, has the same sign as predicted for the reaction mechanism in which the photon interacts with a single quark carrying the spin of the proton. However, the observed value is ~3 times larger than predicted by the generalized-parton-distribution-based calculations, which indicates a significant unknown contribution to the scattering amplitude. PMID:26550716

  6. Intershell correlations in nonresonant Compton scattering of an X-ray photon by an atom

    SciTech Connect

    Hopersky, A. N. Nadolinsky, A. M.; Ikoeva, K. Kh.; Khoroshavina, O. A.

    2011-11-15

    The role of intershell correlations in nonresonant Compton scattering of an X-ray photon by a free multielectron atom is studied theoretically for the Ar atom. The results of calculation are of a predictive nature. The developed mathematical formalism is general in nature and can be applied to a wide set of elements from the Periodic Table, for which the description of the wavefunctions of scattering states in the nonrelativistic Hartree-Fock approximation remains correct.

  7. Electromagnetic Form Factors of the Nucleon and Compton Scattering

    SciTech Connect

    Charles Hyde-Wright; Cornelis De Jager

    2004-12-01

    We review the experimental and theoretical status of elastic electron scattering and elastic low-energy photon scattering (with both real and virtual photons) from the nucleon. As a consequence of new experimental facilities and new theoretical insights, these subjects are advancing with unprecedented precision. These reactions provide many important insights into the spatial distributions and correlations of quarks in the nucleon.

  8. First refraction contrast imaging via Laser-Compton Scattering X-ray at KEK

    SciTech Connect

    Sakaue, Kazuyuki; Aoki, Tatsuro; Washio, Masakazu; Araki, Sakae; Fukuda, Masafumi; Terunuma, Nobuhiro; Urakawa, Junji

    2012-07-31

    Laser-Compton Scattering (LCS) is one of the most feasible techniques for high quality, high brightness, and compact X-ray source. High energy electron beam produced by accelerators scatters off the laser photon at a small spot. As a laser target, we have been developing a pulsedlaser storage cavity for increasing an X-ray flux. The X-ray flux was still inadequate that was 2.1 Multiplication-Sign 10{sup 5}/sec, however, we performed first refraction contrast imaging in order to evaluate the quality of LCS X-ray. Edge enhanced contrast imaging was achieved by changing the distance from sample to detector. The edge enhancement indicates that the LCS X-ray has small source size, i.e. high brightness. We believe that the result has demonstrated good feasibility of linac-based high brightness X-ray sources via laser-electron Compton scatterings.

  9. Time-step limits for a Monte Carlo Compton-scattering method

    SciTech Connect

    Densmore, Jeffery D; Warsa, James S; Lowrie, Robert B

    2008-01-01

    Compton scattering is an important aspect of radiative transfer in high energy density applications. In this process, the frequency and direction of a photon are altered by colliding with a free electron. The change in frequency of a scattered photon results in an energy exchange between the photon and target electron and energy coupling between radiation and matter. Canfield, Howard, and Liang have presented a Monte Carlo method for simulating Compton scattering that models the photon-electron collision kinematics exactly. However, implementing their technique in multiphysics problems that include the effects of radiation-matter energy coupling typically requires evaluating the material temperature at its beginning-of-time-step value. This explicit evaluation can lead to unstable and oscillatory solutions. In this paper, we perform a stability analysis of this Monte Carlo method and present time-step limits that avoid instabilities and nonphysical oscillations by considering a spatially independent, purely scattering radiative-transfer problem. Examining a simplified problem is justified because it isolates the effects of Compton scattering, and existing Monte Carlo techniques can robustly model other physics (such as absorption, emission, sources, and photon streaming). Our analysis begins by simplifying the equations that are solved via Monte Carlo within each time step using the Fokker-Planck approximation. Next, we linearize these approximate equations about an equilibrium solution such that the resulting linearized equations describe perturbations about this equilibrium. We then solve these linearized equations over a time step and determine the corresponding eigenvalues, quantities that can predict the behavior of solutions generated by a Monte Carlo simulation as a function of time-step size and other physical parameters. With these results, we develop our time-step limits. This approach is similar to our recent investigation of time discretizations for the

  10. The integration of improved Monte Carlo compton scattering algorithms into the Integrated TIGER Series.

    SciTech Connect

    Quirk, Thomas, J., IV

    2004-08-01

    The Integrated TIGER Series (ITS) is a software package that solves coupled electron-photon transport problems. ITS performs analog photon tracking for energies between 1 keV and 1 GeV. Unlike its deterministic counterpart, the Monte Carlo calculations of ITS do not require a memory-intensive meshing of phase space; however, its solutions carry statistical variations. Reducing these variations is heavily dependent on runtime. Monte Carlo simulations must therefore be both physically accurate and computationally efficient. Compton scattering is the dominant photon interaction above 100 keV and below 5-10 MeV, with higher cutoffs occurring in lighter atoms. In its current model of Compton scattering, ITS corrects the differential Klein-Nishina cross sections (which assumes a stationary, free electron) with the incoherent scattering function, a function dependent on both the momentum transfer and the atomic number of the scattering medium. While this technique accounts for binding effects on the scattering angle, it excludes the Doppler broadening the Compton line undergoes because of the momentum distribution in each bound state. To correct for these effects, Ribbefor's relativistic impulse approximation (IA) will be employed to create scattering cross section differential in both energy and angle for each element. Using the parameterizations suggested by Brusa et al., scattered photon energies and angle can be accurately sampled at a high efficiency with minimal physical data. Two-body kinematics then dictates the electron's scattered direction and energy. Finally, the atomic ionization is relaxed via Auger emission or fluorescence. Future work will extend these improvements in incoherent scattering to compounds and to adjoint calculations.

  11. COOLING RATES FOR RELATIVISTIC ELECTRONS UNDERGOING COMPTON SCATTERING IN STRONG MAGNETIC FIELDS

    SciTech Connect

    Baring, Matthew G.; Wadiasingh, Zorawar; Gonthier, Peter L. E-mail: zw1@rice.edu

    2011-05-20

    For inner magnetospheric models of hard X-ray and gamma-ray emission in high-field pulsars and magnetars, resonant Compton upscattering is anticipated to be the most efficient process for generating continuum radiation. This is in part due to the proximity of a hot soft photon bath from the stellar surface to putative radiation dissipation regions in the inner magnetosphere. Moreover, because the scattering process becomes resonant at the cyclotron frequency, the effective cross section exceeds the classical Thomson value by over two orders of magnitude, thereby enhancing the efficiency of continuum production and the cooling of relativistic electrons. This paper presents computations of the electron cooling rates for this process, which are needed for resonant Compton models of non-thermal radiation from such highly magnetized pulsars. The computed rates extend previous calculations of magnetic Thomson cooling to the domain of relativistic quantum effects, sampled near and above the quantum critical magnetic field of 44.13 TG. This is the first exposition of fully relativistic, quantum magnetic Compton cooling rates for electrons, and it employs both the traditional Johnson and Lippmann cross section and a newer Sokolov and Ternov (ST) formulation of Compton scattering in strong magnetic fields. Such ST formalism is formally correct for treating spin-dependent effects that are important in the cyclotron resonance and has not been addressed before in the context of cooling by Compton scattering. The QED effects are observed to profoundly lower the rates below extrapolations of the familiar magnetic Thomson results, as expected, when recoil and Klein-Nishina reductions become important.

  12. On the possibility of using X-ray Compton scattering to study magnetoelectrical properties of crystals.

    PubMed

    Collins, S P; Laundy, D; Connolley, T; van der Laan, G; Fabrizi, F; Janssen, O; Cooper, M J; Ebert, H; Mankovsky, S

    2016-03-01

    This paper discusses the possibility of using Compton scattering--an inelastic X-ray scattering process that yields a projection of the electron momentum density--to probe magnetoelectrical properties. It is shown that an antisymmetric component of the momentum density is a unique fingerprint of such time- and parity-odd physics. It is argued that polar ferromagnets are ideal candidates to demonstrate this phenomenon and the first experimental results are shown, on a single-domain crystal of GaFeO3. The measured antisymmetric Compton profile is very small (≃ 10(-5) of the symmetric part) and of the same order of magnitude as the statistical errors. Relativistic first-principles simulations of the antisymmetric Compton profile are presented and it is shown that, while the effect is indeed predicted by theory, and scales with the size of the valence spin-orbit interaction, its magnitude is significantly overestimated. The paper outlines some important constraints on the properties of the antisymmetric Compton profile arising from the underlying crystallographic symmetry of the sample. PMID:26919371

  13. On the possibility of using X-ray Compton scattering to study magnetoelectrical properties of crystals

    PubMed Central

    Collins, S. P.; Laundy, D.; Connolley, T.; van der Laan, G.; Fabrizi, F.; Janssen, O.; Cooper, M. J.; Ebert, H.; Mankovsky, S.

    2016-01-01

    This paper discusses the possibility of using Compton scattering – an inelastic X-ray scattering process that yields a projection of the electron momentum density – to probe magnetoelectrical properties. It is shown that an antisymmetric component of the momentum density is a unique fingerprint of such time- and parity-odd physics. It is argued that polar ferromagnets are ideal candidates to demonstrate this phenomenon and the first experimental results are shown, on a single-domain crystal of GaFeO3. The measured antisymmetric Compton profile is very small (≃ 10−5 of the symmetric part) and of the same order of magnitude as the statistical errors. Relativistic first-principles simulations of the antisymmetric Compton profile are presented and it is shown that, while the effect is indeed predicted by theory, and scales with the size of the valence spin–orbit interaction, its magnitude is significantly overestimated. The paper outlines some important constraints on the properties of the antisymmetric Compton profile arising from the underlying crystallographic symmetry of the sample. PMID:26919371

  14. Estimation of effective atomic number in the Rayleigh to Compton scattering ratio using different methods

    NASA Astrophysics Data System (ADS)

    Kurudirek, M.; Büyükyıldız, M.

    2016-06-01

    The Rayleigh to Compton scattering ratio (R/C) is a very convenient parameter, which can be utilized in material analysis and estimating effective atomic number (Zeff). In the case for a relatively low scattering angle, for which the energy of the Compton scattered photons is not very much different from that of incident photons, the corrections due to self-absorption for Rayleigh and Compton scattering will be roughly equal. Therefore, it enables a result to be obtained which is almost independent of X-ray attenuation inside the sample and it will depend only on the material under investigation. The most frequently used method for calculation of Zeff available in literature is plotting R/C of elements as a function of atomic number and constituting the best fit curve. From this fit curve, the respective Zeff can be determined using R/C of the material. In the present study, we report Zeff of different materials using different methods such as interpolation and direct methods as possible alternatives to the most common fitting method. The results were compared with the experiments wherever possible. The agreement between interpolation method and the fitting method was found to be very satisfactory as relative changes (%) were always less than 9% while the direct method results with somehow significantly higher values of Zeff when compared to the other methods.

  15. Multiple resonant scattering in the Compton upscatter model of gamma-ray bursts

    NASA Technical Reports Server (NTRS)

    Brainerd, J. J.

    1992-01-01

    Resonant Compton scattering, an increasingly popular mechanism for suppressing X-rays and producing gamma rays, must be treated as a multiple-scattering process for conditions thought characteristic of gamma-ray bursts. Photons that multiply scatter with a beamed power-law electron distribution in a uniform magnetic field produce a flat spectrum between the cyclotron frequency and an optical-depth-dependent critical energy; this critical energy ranges between several hundred keV and several MeV. Above this critical energy, the gamma-ray spectrum has a shape determined by the electron distribution and described by a single-scattering model. Only electron distributions that are nearly proportional to the electron momentum are able to simultaneously suppress X-rays and produce a single-scattering spectrum. As the Thomson optical depth approaches unity, photons that experience multiple scatterings often spawn additional photons at a rate that makes the model unphysical.

  16. Nonlinear Compton scattering of ultrashort intense laser pulses

    SciTech Connect

    Seipt, D.; Kaempfer, B.

    2011-02-15

    The scattering of temporally shaped intense laser pulses off electrons is discussed by means of manifestly covariant quantum electrodynamics. We employ a framework based on Volkov states with a time-dependent laser envelope in light-cone coordinates within the Furry picture. An expression for the cross section is constructed unambiguously in respect of the pulse length. A broad distribution of scattered photons with a rich pattern of subpeaks like that obtained in Thomson scattering is found. These broad peaks may overlap at sufficiently high laser intensity, rendering inappropriate the notion of individual harmonics. The limit of monochromatic plane waves as well as the classical limit of Thomson scattering are discussed. As a main result, a scaling law is presented connecting the Thomson limit with the general result for arbitrary kinematics. In the overlapping regions of the spectral density, the classical and quantum calculations give different results, even in the Thomson limit. Thus, a phase-space region is identified where the differential photon distribution is strongly modified by quantum effects.

  17. Investigating the proton structure through polarization transfers in real Compton scattering processes at JLAB

    SciTech Connect

    Fanelli, Cristiano V.; Salme, Giovanni; Wojtsekhowski, Bogdan B.

    2014-06-01

    In the present work, preliminary results of the analysis of polarization transfers in real Compton scattering (RCS) performed in Hall-C at JLAB are presented, for data collected at large scattering angle (θ{sub cm}=70{degrees}) in the experiment E07-002. A previous experiment, E99-114, has already demonstrated a complete inconsistence of its results with a pQCD mechanism at JLAB energy regime. This kind of experiment, therefore, is of crucial importance for understanding the nature of the reaction mechanism for such a simple process, involving a real photon. Furthermore, RCS experiments allow the extraction of Compton form factors and Generalized Parton Distributions (GPDs), the latter connected to the total angular momentum of the nucleon.

  18. COMMISSIONING OF A HIGH-BRIGHTNESS PHOTOINJECTOR FOR COMPTON SCATTERING X-RAY SOURCES

    SciTech Connect

    Anderson, S G; Gibson, D J; Hartemann, F V; Messerly, M; Shverdin, M; Siders, C W; Tremaine, A M; Barty, C J; Badakov, H; Frigola, P; Fukasawa, A; OShea, B; Rosenzweig, J B

    2007-06-21

    Compton scattering of intense laser pulses with ultrarelativistic electron beams has proven to be an attractive source of high-brightness x-rays with keV to MeV energies. This type of x-ray source requires the electron beam brightness to be comparable with that used in x-ray free-electron lasers and laser and plasma based advanced accelerators. We describe the development and commissioning of a 1.6 cell RF photoinjector for use in Compton scattering experiments at LLNL. Injector development issues such as RF cavity design, beam dynamics simulations, emittance diagnostic development, results of sputtered magnesium photo-cathode experiments, and UV laser pulse shaping are discussed. Initial operation of the photoinjector is described.

  19. Quantitative phase retrieval with picosecond X-ray pulses from the ATF Inverse Compton Scattering source

    SciTech Connect

    Endrizzi, M.; Pogorelsky, I.; Gureyev, T.E.; Delogu, P.; Oliva, P.; Golosio, B.; Carpinelli, M.; Yakimenko, Y.; Bottigli, U.

    2011-01-28

    Quantitative phase retrieval is experimentally demonstrated using the Inverse Compton Scattering X-ray source available at the Accelerator Test Facility (ATF) in the Brookhaven National Laboratory. Phase-contrast images are collected using in-line geometry, with a single X-ray pulse of approximate duration of one picosecond. The projected thickness of homogeneous samples of various polymers is recovered quantitatively from the time-averaged intensity of transmitted X-rays. The data are in good agreement with the expectations showing that ATF Inverse Compton Scattering source is suitable for performing phase-sensitive quantitative X-ray imaging on the picosecond scale. The method shows promise for quantitative imaging of fast dynamic phenomena.

  20. A measurement method of a detector response function for monochromatic electrons based on the Compton scattering

    NASA Astrophysics Data System (ADS)

    Bakhlanov, S. V.; Bazlov, N. V.; Derbin, A. V.; Drachnev, I. S.; Kayunov, A. S.; Muratova, V. N.; Semenov, D. A.; Unzhakov, E. V.

    2016-06-01

    In this paper we present a method of scintillation detector energy calibration using the gamma-rays. The technique is based on the Compton scattering of gamma-rays in a scintillation detector and subsequent photoelectric absorption of the scattered photon in the Ge-detector. The novelty of this method is that the source of gamma rays, the germanium and scintillation detectors are immediately arranged adjacent to each other. The method presents an effective solution for the detectors consisting of a low atomic number materials, when the ratio between Compton effect and photoelectric absorption is large and the mean path of gamma-rays is comparable to the size of the detector. The technique can be used for the precision measurements of the scintillator light yield dependence on the electron energy.

  1. Study of the proton structure by measurements of polarization transfers in real Compton scattering at Jlab

    SciTech Connect

    Fanelli, Cristiano Fanelli; Cisbani, Evarostp; Hamilton, David; Salme, G.; Wojtsekhowski, Bogdan B.

    2014-03-01

    A preliminary analysis of polarization-transfer data at large scattering angle (70°), obtained in an experiment of real Compton scattering on proton, performed in Hall-C of Jefferson Lab, is presented. It is also discussed the relevance of this kind of experiments for shedding light on the non-perturbative structure of the proton, at low energy, and on the transition from the non-perturbative regime to the perturbative one, that occurs at high energy. Moreover, the possibility to extract Compton form factors and the Generalized Parton Distributions, one of the most promising theoretical tool to determine the total angular momentum contribution of quarks and gluons to nucleon spin, is emphasized.

  2. Compton scattering from a pion: Off-shell effects and the equivalence theorem

    SciTech Connect

    Scherer, S.; Fearing, H.W.

    1995-05-10

    We consider Compton scattering from a pion in the framework of chiral perturbation theory ({chi}{ital PT}). We investigate off-shell effects in the s- and u-channel pole diagrams. For that purpose we perform a field transformation which, in comparison with the standard Gasser and Leutwyler lagrangian, generates additional terms at order {ital p}{sup 4} proportional to the lowest-order equation of motion. We demonstrate that the two lagrangians which generate different off-shell form factors predict the same Compton scattering S-matrix. This result is interpreted as an application of a generalized equivalence theorem. {copyright} {ital 1995} {ital American} {ital Institute} {ital of} {ital Physics}.

  3. Laser Compton Scattering Gamma-Ray Beam Source at NewSUBARU Storage Ring

    NASA Astrophysics Data System (ADS)

    Miyamoto, S.; Amano, S.; Hashimoto, S.; Sakai, N.; Koizumi, A.; Hashimoto, T.; Shizuma, T.; Utsunomiya, H.; Yamagata, T.; Akimune, H.; Shima, T.; Li, D.; Asano, Y.; Ohkuma, H.

    2015-10-01

    Laser Compton scattering gamma-ray beam source has been developed at the NewSUBARU synchrotron light facility. The available maximum Gamma-ray photon energy is 76 MeV. The flux of quasi-monochromatic gamma-ray photons (for example: 16.7 MeV, ΔE/E ~ 5%) is more than 106photons/sec using a 35 W Nd:YVO4 laser combined with the 1 GeV storage electron beam with an intensity of 300 mA. We used the electron beams at Ee = 0.55 ~ 1.47 GeV for changing the energy of quasi-monochromatic gamma-ray beam. Gamma-ray beams were used for application experiments, a nuclear physics research, a nondestructive inspection of thick material, a generation of positron by pair creation, a magnetic Compton scattering measurements, and a nuclear transmutation.

  4. ON THE SPECTRAL SHAPE OF RADIATION DUE TO INVERSE COMPTON SCATTERING CLOSE TO THE MAXIMUM CUTOFF

    SciTech Connect

    Lefa, E.; Kelner, S. R.; Aharonian, F. A.

    2012-07-10

    The spectral shape of radiation due to inverse Compton scattering is analyzed in the Thomson and the Klein-Nishina regime for electron distributions with exponential cutoff. We derive analytical, asymptotic expressions for the spectrum close to the maximum cutoff region. We consider monoenergetic, Planckian, and synchrotron photons as target photon fields. These approximations provide a direct link between the distribution of parent electrons and the upscattered spectrum at the cutoff region.

  5. Different ways of dealing with Compton scattering and positron annihilation experimental data

    NASA Astrophysics Data System (ADS)

    Kontrym-Sznajd, G.; Samsel-Czekała, M.

    2005-05-01

    Different ways of dealing with one-dimensional (1D) spectra, measured e.g., in the Compton scattering or angular correlation of positron annihilation radiation (ACAR) experiments, are presented. Using the example of divalent hexagonal close packed metals, we show what kind of information on the electronic structure one can get from 1D profiles interpreted in terms of either 2D or 3D momentum densities.

  6. Time-step limits for a Monte Carlo Compton-scattering method

    SciTech Connect

    Densmore, Jeffery D; Warsa, James S; Lowrie, Robert B

    2009-01-01

    We perform a stability analysis of a Monte Carlo method for simulating the Compton scattering of photons by free electron in high energy density applications and develop time-step limits that avoid unstable and oscillatory solutions. Implementing this Monte Carlo technique in multi physics problems typically requires evaluating the material temperature at its beginning-of-time-step value, which can lead to this undesirable behavior. With a set of numerical examples, we demonstrate the efficacy of our time-step limits.

  7. A simple method for computing the relativistic Compton scattering kernel for radiative transfer

    NASA Technical Reports Server (NTRS)

    Prasad, M. K.; Kershaw, D. S.; Beason, J. D.

    1986-01-01

    Correct computation of the Compton scattering kernel (CSK), defined to be the Klein-Nishina differential cross section averaged over a relativistic Maxwellian electron distribution, is reported. The CSK is analytically reduced to a single integral, which can then be rapidly evaluated using a power series expansion, asymptotic series, and rational approximation for sigma(s). The CSK calculation has application to production codes that aim at understanding certain astrophysical, laser fusion, and nuclear weapons effects phenomena.

  8. Generalized polarizabilities and the spin-averaged amplitude in virtual Compton scattering off the nucleon

    SciTech Connect

    Drechsel, D.; Knoechlein, G.; Metz, A.; Scherer, S.

    1997-01-01

    We discuss the low-energy behavior of the spin-averaged amplitude of virtual Compton scattering off a nucleon. Based on gauge invariance, Lorentz invariance, and the discrete symmetries, it is shown that to first order in the frequency of the final real photon only two generalized polarizabilities appear. Different low-energy expansion schemes are discussed and put into perspective. {copyright} {ital 1997} {ital The American Physical Society}

  9. Laser Compton scattering experiments and the latest developments in construction of experimental facilities at SINAP

    NASA Astrophysics Data System (ADS)

    Luo, W.; Xu, W.; Pan, Q. Y.; Fan, G. T.; Fan, G. W.; Li, Y. J.; Lin, G. Q.; Xu, B. J.; Xu, Y.; Yan, Z.; Yang, L. F.

    2009-07-01

    In this article, we report the two terms Laser Compton Scattering (LCS) via interaction experiments at 100 MeV linear accelerator of SINAP. The monochromatic X-rays were generated by a 108.1 MeV, 2.5 ns electron beam colliding with two Nd:YAG lasers of 113mJ/pulse,35 ns and 2J/pulse, 10 ns, respectively, and demonstrate the latest developments in construction of experimental facilities at SINAP: a high-intensity ultrafast laser and electron interaction experimental facility based on Shanghai Deep Ultraviolet-Free Electron Laser (SDUV-FEL) device. In addition, we present a future Laser Compton Scattering (LCS) γ-ray source - Shanghai Laser Electron Gamma Source (SLEGS) at Shanghai Synchrotron Radiation Facility (SSRF) is presented. It is one of beamlines of SSRF in Phase II and will be finished around 2011. Key words: Laser Compton Scattering (LCS); Shanghai Laser Electron Gamma Source (SLEGS); 100MeV & 150MeV Linac; Shanghai Synchrotron Radiation Facility (SSRF);

  10. Why criteria for impulse approximation in Compton scattering fail in relativistic regimes

    NASA Astrophysics Data System (ADS)

    Lajohn, L. A.; Pratt, R. H.

    2014-05-01

    The assumption behind impulse approximation (IA) for Compton scattering is that the momentum transfer q is much greater than the average < p > of the initial bound state momentum distribution p. Comparing with S-matrix results, we find that at relativistic incident photon energies (ωi) and for high Z elements, one requires information beyond < p > / q to predict the accuracy of relativistic IA (RIA) diferential cross sections. The IA expression is proportional to the product of a kinematic factor Xnr and the symmetrical Compton profile J, where Xnr = 1 + cos2 θ (θ is the photon scattering angle). In the RIA case, Xnr, independent of p, is replaced by Xrel (ω , θ , p) in the integrand which determines J. At nr energies there is virtually no RIA error in the position of the Compton peak maximum (ωfpk) in the scattered photon energy (ωf), while RIA error in the peak magnitude can be characterized by < p > / q . This is because at low ωi, the kinematic effects described by S-matrix (also RIA) expressions behave like Xnr, while in relativistic regimes (high ωi and Z), kinematic factors treated accurately by S-matrix but not RIA expressions become significant and do not factor out.

  11. Compton scattering, meson exchange, and the polarizabilities of bound nucleons

    NASA Astrophysics Data System (ADS)

    Feldman, G.; Mellendorf, K. E.; Eisenstein, R. A.; Federspiel, F. J.; Garino, G.; Igarashi, R.; Kolb, N. R.; Lucas, M. A.; MacGibbon, B. E.; Mize, W. K.; Nathan, A. M.; Pywell, R. E.; Wells, D. P.

    1996-11-01

    Elastic photon scattering cross sections on 16O have been measured in the energy range 27-108 MeV. These data are inconsistent with a conventional interpretation in which the electric and magnetic polarizabilities of the bound nucleon are unchanged from the free values and the meson-exchange seagull amplitude is taken in the zero-energy limit. Agreement with the data can be achieved by invoking either strongly modified polarizabilities or a substantial energy dependence to the meson-exchange seagull amplitude. It is argued that these seemingly different explanations are experimentally indistinguishable and probably physically equivalent.

  12. A novel method for non-destructive Compton scatter imaging based on the genetic algorithm

    NASA Astrophysics Data System (ADS)

    Ashrafi, Saleh; Jahanbakhsh, Okhtay; Alizadeh, Davood; Salehpour, Behrooz

    2013-05-01

    Compton scattering tomography is widely used in numerous applications such as biomedical imaging, nondestructive industrial testing and environmental survey, etc. This paper proposes the use of the genetic algorithm (GA), which utilizes bio-inspired mathematical models, to construct an image of the insides of a test object via the scattered photons, from a voxel within the object. A NaI(Tl) scintillation detector and a 185 MBq 137Cs gamma ray source were used in the experimental measurements. The obtained results show that the proposed GA based method performs well in constructing images of objects.

  13. Relativistic electron beam acceleration by Compton scattering of extraordinary waves

    SciTech Connect

    Sugaya, R.

    2006-05-15

    Relativistic transport equations, which demonstrate that relativistic and nonrelativistic particle acceleration along and across a magnetic field and the generation of an electric field transverse to the magnetic field, are induced by nonlinear wave-particle scattering (nonlinear Landau and cyclotron damping) of almost perpendicularly propagating electromagnetic waves in a relativistic magnetized plasma were derived from the relativistic Vlasov-Maxwell equations. The relativistic transport equations show that electromagnetic waves can accelerate particles in the k{sup ''} direction (k{sup ''}=k-k{sup '}). Simultaneously, an intense cross-field electric field, E{sub 0}=B{sub 0}xv{sub d}/c, is generated via the dynamo effect owing to perpendicular particle drift to satisfy the generalized Ohm's law, which means that this cross-field particle drift is identical to the ExB drift. On the basis of these equations, acceleration and heating of a relativistic electron beam due to nonlinear wave-particle scattering of electromagnetic waves in a magnetized plasma were investigated theoretically and numerically. Two electromagnetic waves interact nonlinearly with the relativistic electron beam, satisfying the resonance condition of {omega}{sub k}-{omega}{sub k{sup '}}-(k{sub perpendicular}-k{sub perpendicula=} r{sup '})v{sub d}-(k{sub parallel}-k{sub parallel}{sup '})v{sub b}{approx_equal}m{omega}{sub ce}, where v{sub b} and v{sub d} are the parallel and perpendicular velocities of the relativistic electron beam, respectively, and {omega}{sub ce} is the relativistic electron cyclotron frequency. The relativistic transport equations using the relativistic drifted Maxwellian momentum distribution function of the relativistic electron beam were derived and analyzed. It was verified numerically that extraordinary waves can accelerate the highly relativistic electron beam efficiently with {beta}m{sub e}c{sup 2} < or approx. 1 GeV, where {beta}=(1-v{sub b}{sup 2}/c{sup 2}){sup -1/2}.

  14. An algorithm and program for data processing from a Compton scattering imaging device

    NASA Astrophysics Data System (ADS)

    Vasiliev, V. N.; Zaytseva, K. V.

    2005-07-01

    The VolumeScope, a prototype 3D X-ray scanner based on Compton backscatter detection, was designed for examination of a human body electron density distribution. An algorithm and computer program for 3D image reconstruction from the VolumeScope measured data are presented. The reconstruction includes corrections for photon attenuation and multiple scatter in surrounding tissues and postprocessing digital filtering. Properties of multiple scattered photons inside the object of examination were studied by Monte Carlo technique and a geometrical efficiency of the multiple scatter detection was calculated on the base of the collimator design. The contribution of multiple scattered photons in semi-infinite water medium was from 15 to 23% of maximum detector response. The VolumeScope program is described to perform data processing and display the electron density distribution of the object as 2D grayscale images and 3D surfaces of internal structures.

  15. Diffusion Compton profondement virtuelle dans le Hall A au Jefferson Laboratory

    SciTech Connect

    Camacho, Carlos Munoz

    2005-12-01

    Generalized Parton Distributions (GPDs), introduced in the late 90s, provide a universal description of hadrons in terms of the underlying degrees of freedom of Quantum Chromodynamics: quarks and gluons. GPDs appear in a wide variety of hard exclusive reactions and the advent of high luminosity accelerator facilities has made the study of GPDs accessible to experiment. Deeply Virtual Compton Scattering (DVCS) is the golden process involving GPDs. The first dedicated DVCS experiment ran in the Hall A of Jefferson Lab in Fall 2004. An electromagnetic calorimeter and a plastic scintillator detector were constructed for this experiment, together with specific electronics and acquisition system. The experiment preparation, data taking and analysis are described in this document. Results on the absolute cross section difference for opposite beam helicities provide the first measurement of a linear combination of GPDs as a function of the momentum transfer to the nucleon.

  16. Analytical results for nonlinear Compton scattering in short intense laser pulses

    NASA Astrophysics Data System (ADS)

    Seipt, Daniel; Kharin, Vasily; Rykovanov, Sergey; Surzhykov, Andrey; Fritzsche, Stephan

    2016-04-01

    > We study in detail the strong-field QED process of nonlinear Compton scattering in short intense plane wave laser pulses of circular polarization. Our main focus is placed on how the spectrum of the backscattered laser light depends on the shape and duration of the initial short intense pulse. Although this pulse shape dependence is very complicated and highly nonlinear, and has never been addressed explicitly, our analysis reveals that all the dependence on the laser pulse shape is contained in a class of three-parameter master integrals. Here we present completely analytical expressions for the nonlinear Compton spectrum in terms of these master integrals. Moreover, we analyse the universal behaviour of the shape of the spectrum for very high harmonic lines.

  17. Stability analysis and time-step limits for a Monte Carlo Compton-scattering method

    SciTech Connect

    Densmore, Jeffery D. Warsa, James S. Lowrie, Robert B.

    2010-05-20

    A Monte Carlo method for simulating Compton scattering in high energy density applications has been presented that models the photon-electron collision kinematics exactly [E. Canfield, W.M. Howard, E.P. Liang, Inverse Comptonization by one-dimensional relativistic electrons, Astrophys. J. 323 (1987) 565]. However, implementing this technique typically requires an explicit evaluation of the material temperature, which can lead to unstable and oscillatory solutions. In this paper, we perform a stability analysis of this Monte Carlo method and develop two time-step limits that avoid undesirable behavior. The first time-step limit prevents instabilities, while the second, more restrictive time-step limit avoids both instabilities and nonphysical oscillations. With a set of numerical examples, we demonstrate the efficacy of these time-step limits.

  18. Electron momentum density of TTF-TCNQ (tetrathiafulvalene-tetracyanoquinodimethane) studied by Compton scattering

    NASA Astrophysics Data System (ADS)

    Ishibashi, Shoji; Manuel, Alfred A.; Vasumathi, Dharmavaram; Shukla, Abhay; Suortti, Pekka; Kohyama, Masanori; Bechgaard, Klaus

    1999-11-01

    We have investigated the electronic structure of the quasi-one-dimensional organic metal TTF-TCNQ by measuring Compton scattering from single crystals. The measured profiles are significantly anisotropic. The directional anisotropies were compared with those derived by two different theoretical approaches. The first is the molecular orbital approximation: Compton profiles were calculated for the TTF and TCNQ molecules, separately, and then these were superposed. In spite of the simplicity of this approach, the agreement is reasonably good, implying that the electronic wave functions of TTF and TCNQ in the crystal are not very different from those of isolated molecules. The second approach is an ab initio pseudopotential band-structure calculation. The agreement is better, presumably due to the more accurate description of the crystallinity (including, for example, the inter-molecule charge transfer and band formation).

  19. Separation of Proton Polarizabilities with the Beam Asymmetry of Compton Scattering

    NASA Astrophysics Data System (ADS)

    Krupina, Nadiia; Pascalutsa, Vladimir

    2013-06-01

    We propose to determine the magnetic dipole polarizability of the proton from the beam asymmetry of low-energy Compton scattering based on the fact that the leading non-Born contribution to the asymmetry is given by the magnetic polarizability alone; the electric polarizability cancels out. The beam asymmetry thus provides a simple and clean separation of the magnetic polarizability from the electric one. Introducing polarizabilities in a Lorentz-invariant fashion, we compute the higher-order (recoil) effects of polarizabilities on beam asymmetry and show that these effects are suppressed in forward kinematics. With the prospects of precision Compton experiments at the Mainz Microtron and High Intensity Gamma Source facilities in mind, we argue why the beam asymmetry could be the best way to measure the elusive magnetic polarizability of the proton.

  20. X-ray Compton scattering experiments for fluid alkali metals at high temperatures and pressures

    SciTech Connect

    Matsuda, K. Fukumaru, T.; Kimura, K.; Yao, M.; Tamura, K.; Katoh, M.; Kajihara, Y.; Inui, M.; Itou, M.; Sakurai, Y.

    2015-08-17

    We have developed a high-pressure vessel and a cell for x-ray Compton scattering measurements of fluid alkali metals. Measurements have been successfully carried out for alkali metal rubidium at elevated temperatures and pressures using synchrotron radiation at SPring-8. The width of Compton profiles (CPs) of fluid rubidium becomes narrow with decreasing fluid density, which indicates that the CPs sensitively detect the effect of reduction in the valence electron density. At the request of all authors of the paper, and with the agreement of the Proceedings Editor, an updated version of this article was published on 10 September 2015. The original article supplied to AIP Publishing was not the final version and contained PDF conversion errors in Formulas (1) and (2). The errors have been corrected in the updated and re-published article.

  1. The use of Compton scattering in detecting anomaly in soil-possible use in pyromaterial detection

    NASA Astrophysics Data System (ADS)

    Abedin, Ahmad Firdaus Zainal; Ibrahim, Noorddin; Zabidi, Noriza Ahmad; Demon, Siti Zulaikha Ngah

    2016-01-01

    The Compton scattering is able to determine the signature of land mine detection based on dependency of density anomaly and energy change of scattered photons. In this study, 4.43 MeV gamma of the Am-Be source was used to perform Compton scattering. Two detectors were placed between source with distance of 8 cm and radius of 1.9 cm. Detectors of thallium-doped sodium iodide NaI(TI) was used for detecting gamma ray. There are 9 anomalies used in this simulation. The physical of anomaly is in cylinder form with radius of 10 cm and 8.9 cm height. The anomaly is buried 5 cm deep in the bed soil measured 80 cm radius and 53.5 cm height. Monte Carlo methods indicated the scattering of photons is directly proportional to density of anomalies. The difference between detector response with anomaly and without anomaly namely contrast ratio values are in a linear relationship with density of anomalies. Anomalies of air, wood and water give positive contrast ratio values whereas explosive, sand, concrete, graphite, limestone and polyethylene give negative contrast ratio values. Overall, the contrast ratio values are greater than 2 % for all anomalies. The strong contrast ratios result a good detection capability and distinction between anomalies.

  2. HERMES impact for the access of Compton form factors

    NASA Astrophysics Data System (ADS)

    Kumerički, K.; Müller, D.; Murray, M.

    2014-07-01

    We utilize the DVCS asymmetry measurements of the HERMES collaboration for access to Compton form factors in the deeply virtual regime and to generalized parton distributions. In particular, the (almost) complete measurement of DVCS observables allows us to map various asymmetries into the space of Compton form factors, where we still rely in this analysis on dominance of twist-two associated Compton form factors. We compare this one-to-one map with local Compton form factor fits and a model dependent global fit.

  3. Compton Scattering by Static and Moving Media. Part 1; The Transfer Equation and its Moments

    NASA Technical Reports Server (NTRS)

    Psaltis, Dimitrios; Lamb, Frederick K.

    1997-01-01

    Compton scattering of photons by nonrelativistic particles is thought to play an important role in forming the radiation spectrum of many astrophysical systems. Here we derive the time-dependent photon kinetic equation that describes spontaneous and induced Compton scattering, as well as absorption and emission by static and moving media, the corresponding radiative transfer equation, and their zeroth and first angular moments, both in the system frame and in the frame comoving with the medium. We show that it is necessary to use the correct relativistic differential scattering cross section in order to obtain a photon kinetic equation that is correct to first order in Epsilon/m(sub e), T(sub e)/m(sub e), and V, where Epsilon is the photon energy, T(sub e) and m(sub e) are the electron temperature and rest mass, and V is the electron bulk velocity in units of the speed of light. We also demonstrate that the terms in the radiative transfer equation that are second order in V should usually be retained, because if the radiation energy density is sufficiently large, compared to the radiation flux, the effects of bulk Comptonization described by the terms that are second order in V can be as important as the effects described by the terms that are first order in V, even when V is small. The system- and fluid-frame equations that we derive are correct to first order in Epsilon/m(sub e). Our system-frame equations, which are correct to second order in V, may be used when V is not too large. Our fluid-frame equations, which are exact in V, may be used when V approaches 1. Both sets of equations are valid for systems of arbitrary optical depth and can therefore be used in both the free-streaming and diffusion regimes. We demonstrate that Comptonization by the electron bulk motion occurs whether or not the radiation field is isotropic or the bulk flow converges and that it is more important than thermal Comptonization if V(sup 2) is greater than 3T(sub e)/m(sub e).

  4. Polarization transfer in wide-angle Compton scattering and single-pion photoproduction from the proton

    SciTech Connect

    Fanelli, Cristiano V.

    2015-10-06

    Wide-angle exclusive Compton scattering and single-pion photoproduction from the proton have been investigated via measurement of the polarization transfer from a circularly polarized photon beam to the recoil proton. The WACS polarization transfer was analyzed at an incident photon energy of 3.7 GeV at a proton scattering angle of θPcm = 70°. The longitudinal transfer KLL, measured to be 0.645 ± 0.059 ± 0.048, where the first error is statistical and the second is systematic, has the same sign as predicted for the reaction mechanism in which the photon interacts with a single quark carrying the spin of the proton. However, the observed value is ~3 times larger than predicted by the GPD-based calculations, which indicates a significant unknown contribution to the scattering amplitude.

  5. Polarization transfer in wide-angle Compton scattering and single-pion photoproduction from the proton

    DOE PAGESBeta

    Fanelli, Cristiano V.

    2015-10-06

    Wide-angle exclusive Compton scattering and single-pion photoproduction from the proton have been investigated via measurement of the polarization transfer from a circularly polarized photon beam to the recoil proton. The WACS polarization transfer was analyzed at an incident photon energy of 3.7 GeV at a proton scattering angle of θPcm = 70°. The longitudinal transfer KLL, measured to be 0.645 ± 0.059 ± 0.048, where the first error is statistical and the second is systematic, has the same sign as predicted for the reaction mechanism in which the photon interacts with a single quark carrying the spin of the proton.more » However, the observed value is ~3 times larger than predicted by the GPD-based calculations, which indicates a significant unknown contribution to the scattering amplitude.« less

  6. Spatially resolved hard X-ray polarization in solar flares: effects of Compton scattering and bremsstrahlung

    NASA Astrophysics Data System (ADS)

    Jeffrey, N. L. S.; Kontar, E. P.

    2011-12-01

    Aims: We study the polarization of hard X-ray (HXR) sources in the solar atmosphere, including Compton backscattering of photons in the photosphere (the albedo effect) and the spatial distribution of polarization across the source. Methods: HXR photon polarization and spectra produced via electron-ion bremsstrahlung emission are calculated from various electron distributions typical for solar flares. Compton scattering and photoelectric absorption are then modelled using Monte Carlo simulations of photon transport in the photosphere to study the observed (primary and albedo) sources. Polarization maps across HXR sources (primary and albedo components) for each of the modelled electron distributions are calculated at various source locations from the solar centre to the limb. Results: We show that Compton scattering produces a distinct polarization variation across the albedo patch at peak albedo energies of 20-50 keV for all anisotropies modelled. The results show that there are distinct spatial polarization changes in both the radial and perpendicular to radial directions across the extent of the HXR source at a given disk location. In the radial direction, the polarization magnitude and direction at specific positions along the HXR source will either increase or decrease with increased photon distribution directivity towards the photosphere. We also show how high electron cutoff energies influence the direction of polarization at above ~100 keV. Conclusions: Spatially resolved HXR polarization measurements can provide important information about the directivity and energetics of the electron distribution. Our results indicate the preferred angular resolution of polarization measurements required to distinguish between the scattered and primary components. We also show how spatially resolved polarization measurements could be used to probe the emission pattern of an HXR source, using both the magnitude and the direction of the polarization.

  7. Correction of radiation absorption on biological samples using Rayleigh to Compton scattering ratio

    NASA Astrophysics Data System (ADS)

    Pereira, Marcelo O.; Conti, Claudio de Carvalho; dos Anjos, Marcelino J.; Lopes, Ricardo T.

    2012-06-01

    The aim of this work was to develop a method to correct the absorbed radiation (the mass attenuation coefficient curve) in low energy (E < 30 keV) applied to a biological matrix based on the Rayleigh to Compton scattering ratio and the effective atomic number. For calibration, scattering measurements were performed on standard samples of radiation produced by a gamma-ray source of 241Am (59.54 keV) also applied to certified biological samples of milk powder, hay powder and bovine liver (NIST 1557B). In addition, six methods of effective atomic number determination were used as described in literature to determinate the Rayleigh to Compton scattering ratio (R/C), in order to calculate the mass attenuation coefficient. The results obtained by the proposed method were compared with those obtained using the transmission method. The experimental results were in good agreement with transmission values suggesting that the method to correct radiation absorption presented in this paper is adequate for biological samples.

  8. Wide angle Compton scattering on the proton: study of power suppressed corrections

    NASA Astrophysics Data System (ADS)

    Kivel, N.; Vanderhaeghen, M.

    2015-10-01

    We study the wide angle Compton scattering process on a proton within the soft-collinear factorization (SCET) framework. The main purpose of this work is to estimate the effect due to certain power suppressed corrections. We consider all possible kinematical power corrections and also include the subleading amplitudes describing the scattering with nucleon helicity flip. Under certain assumptions we present a leading-order factorization formula for these amplitudes which includes the hard- and soft-spectator contributions. We apply the formalism and perform a phenomenological analysis of the cross section and asymmetries in the wide angle Compton scattering on a proton. We assume that in the relevant kinematical region where -t,-u>2.5 GeV2 the dominant contribution is provided by the soft-spectator mechanism. The hard coefficient functions of the corresponding SCET operators are taken in the leading-order approximation. The analysis of existing cross section data shows that the contribution of the helicity-flip amplitudes to this observable is quite small and comparable with other expected theoretical uncertainties. We also show predictions for double polarization observables for which experimental information exists.

  9. Compton Scattering and Its Applications: The PLEIADES Femtosecond X-ray Source at LLNL

    SciTech Connect

    Hartemann, F V; Brown, W J; Anderson, S G; Barty, C P J; Betts, S M; Booth, R; Crane, J K; Cross, R R; Fittinghoff, D N; Gibson, D J; Kuba, J; Rupp, B; Tremaine, A M; Springer, P T

    2003-05-01

    Remarkable developments in critical technologies including terawatt-class lasers using chirped-pulse amplification, high brightness photoinjectors, high-gradient accelerators, and superconducting linacs make it possible to design and operate compact, tunable, subpicosecond Compton scattering x-ray sources with a wide variety of applications. In such novel radiation sources, the collision between a femtosecond laser pulse and a low emittance relativistic electron bunch in a small ({micro}m{sup 3}) interaction volume produces Doppler-upshifted scattered photons with unique characteristics: the energy is tunable in the 5-500 keV range, the angular divergence of the beam is small (mrad), and the pulses are ultrashort (10 fs - 10 ps). Two main paths are currently being followed in laboratories worldwide: high peak brightness, using ultrahigh intensity femtosecond lasers at modest repetition rates, and high average brightness, using superconducting linac and high average power laser technology at MHz repetition rates. Targeted applications range from x-ray protein crystallography and high contrast medical imaging to femtosecond pump-probe and diffraction experiments. More exotic uses of such sources include the {gamma}-{gamma} collider, NIF backlighting, nonlinear Compton scattering, and high-field QED. Theoretical considerations and experimental results will be discussed within this context.

  10. Expected level of self-Compton scattering in radio loud quasars

    NASA Technical Reports Server (NTRS)

    Bloom, Steven D.; Marscher, Alan P.

    1992-01-01

    Radio-loud quasars usually contain parsec-scale nonthermal jets. The most compact emission region ('the core'), and perhaps some of the moving 'knots', are expected to be efficient producers of inverse Compton scattered X-rays and gamma-rays since many of the synchrotron photons will upscatter before escaping. Through multifrequency flux density observations and Very Long Baseline Interferometry (VLBI) measurements of angular sizes, one can predict the flux density of this self-Compton high-energy emission. It is not always the case that the brightest synchrotron sources are also the brightest X-ray and gamma-ray sources. Perhaps a better predictor of high-energy brightness is the ratio of hard X-ray to high-frequency radio emission. Using the synchrotron self-Compton relations, we predict the gamma-ray fluxes of several sources we expect to be detected by the Energetic Gamma Ray Experiment Telescope (EGRET). More accurate predictions will be made when we complete a program of contemporaneous radio-submillimeter and X-ray observations during the course of the EGRET all-sky survey.

  11. Compton scattering off polarized electrons with a high-finesse Fabry-Perot Cavity at Jlab

    SciTech Connect

    Nicolas Falletto; Martial Authier; Maud Baylac; M. Boyer; Francois Bugeon; Etienne Burtin; Christian Cavata; Nathalie Colombel; G. Congretel; R. Coquillard; G. Coulloux; Bertrand Couzy; P Deck; Alain Delbart; D. Desforges; A. Donati; B. Duboue; Stephanie Escoffier; F. Farci; Bernard Frois; P Girardot; J Guillotau; C Henriot; Claude Jeanney; M Juillard; J. P. Jorda; P. Legou; David Lhuillier; Y Lussignol; Phillippe Mangeot; X. Martin; Frederic Marie; Jacques Martino; M. Maurier; Bernard Mazeau; J.F. Millot; F. Molinie; J.-P. Mols; Jean-pierre Mouly; M. Mur; Damien Neyret; T. Pedrol; Stephane Platchkov; G. Pontet; Thierry Pussieux; Yannick Queinec; Philippe Rebourgeard; J. C. Sellier; Gerard Tarte; Christian Veyssiere; Andre Zakarian; Pierre Bertin; Alain Cosquer; Jian-ping Chen; Joseph Mitchell; J.-M. Mackowski; L. Pinard

    2001-03-01

    We built and commissioned a new type of Compton polarimeter to measure the electron beam polarization at the Thomas Jefferson National Accelerator Facility (Virginia, USA). The heart of this polarimeter is a high-finesse monolithic Fabry-Perot cavity. Its purpose is to amplify a primary 300 mW laser beam in order to improve the signal to noise ratio of the polarimeter. It is the first time that a high-finesse Fabry-Perot cavity is enclosed in the vacuum of a particle accelerator to monitor the beam polarization by Compton polarimetry. The measured finesse and amplification gain of the cavity are F=26000 and G=7300. The electron beam crosses this high-power photon source at an angle of 23 mrad in the middle of the cavity where the photon beam power density is estimated to be 0.85MW/cm2. We have used this facility during the HAPPEX experiment (April-July 1999) and we give a preliminary measurement of Compton scattering asymmetry.

  12. Compton scatter axial tomography with x-rays: SCAT-CAT.

    PubMed

    Brateman, L; Jacobs, A M; Fitzgerald, L T

    1984-11-01

    A method of extracting information from the backscattered field produced in parallel beam x-ray computed tomography (CT) is presented. A calculational model to predict the backscattered field based on Compton scattering is described, and the model is verified by measurements of simple phantoms. The phantoms tested--cylinders of polymethylmethacrylate (PMM) with air gaps and aluminium rods placed internally--are irradiated on a scanning assembly, built to simulate a first generation CT scanner with a transmission and a scatter detector (the SCAT-CAT). Data from the transmission detector are reconstructed by traditional CT methods to provide a transmission image; it is the data from the backscatter detector which are analysed in this study. After verification of the model for the scattered field calculations, a method of extracting information from the scattered field is developed, based on ratios of scatter signals from non-uniform to uniform phantoms. This method is demonstrated for predicted data of a simulated phantom and for measured data of the same and two additional phantoms. The method is very sensitive to air gaps in the phantoms because of the relative electron density of air with respect to PMM; it is not as sensitive to aluminium rods for the same reason. Various methods of applying the scattered field information to produce an image representing a simulated phantom are considered, and a preferred method is chosen to reconstruct scattered field data into an image for the three phantoms studied. PMID:6505017

  13. Compton-Scattering Cross Section on the Proton at High Momentum Transfer

    SciTech Connect

    Danagoulian, A.; Roedelbronn, M.; Chang, T.-H.; Nathan, A. M.; Mamyan, V. H.; Aniol, K. A.; Margaziotis, D. J.; Annand, J. R. M.; Hamilton, D. J.; Bertin, P. Y.; Camsonne, A.; Laveissiere, G.; Bosted, P.; Paschke, K.; Calarco, J. R.; Chang, C. C.; Horn, T.; Savvinov, N.; Chen, J.-P.

    2007-04-13

    Cross-section values for Compton scattering on the proton were measured at 25 kinematic settings over the range s=5-11 and -t=2-7 GeV{sup 2} with a statistical accuracy of a few percent. The scaling power for the s dependence of the cross section at fixed center-of-mass angle was found to be 8.0{+-}0.2, strongly inconsistent with the prediction of perturbative QCD. The observed cross-section values are in fair agreement with the calculations using the handbag mechanism, in which the external photons couple to a single quark.

  14. Performance of the Laser Compton Scattering Gamma-Ray Source at SAGA-LS

    NASA Astrophysics Data System (ADS)

    Kaneyasu, T.; Takabayashi, Y.; Iwasaki, Y.; Koda, S.

    2013-03-01

    A laser Compton scattering gamma-ray source was constructed at the SAGA light source facility. To produce high-flux gamma rays in the few MeV region, we used a CO2 laser with a 10.6 μm wavelength. Head-on collisions between the laser photons and the 1.4 GeV electron beam in the storage ring can produce gamma rays up to a maximum energy of 3.5 MeV without affecting the light source performance. The performance of the LCS source with respect to the stability of gamma-ray flux during continuous operation is reported.

  15. Compton-scattering cross section on the proton at high momentum transfer.

    PubMed

    Danagoulian, A; Mamyan, V H; Roedelbronn, M; Aniol, K A; Annand, J R M; Bertin, P Y; Bimbot, L; Bosted, P; Calarco, J R; Camsonne, A; Chang, C C; Chang, T-H; Chen, J-P; Choi, Seonho; Chudakov, E; Degtyarenko, P; de Jager, C W; Deur, A; Dutta, D; Egiyan, K; Gao, H; Garibaldi, F; Gayou, O; Gilman, R; Glamazdin, A; Glashausser, C; Gomez, J; Hamilton, D J; Hansen, J-O; Hayes, D; Higinbotham, D W; Hinton, W; Horn, T; Howell, C; Hunyady, T; Hyde, C E; Jiang, X; Jones, M K; Khandaker, M; Ketikyan, A; Kubarovsky, V; Kramer, K; Kumbartzki, G; Laveissière, G; Lerose, J; Lindgren, R A; Margaziotis, D J; Markowitz, P; McCormick, K; Meekins, D G; Meziani, Z-E; Michaels, R; Moussiegt, P; Nanda, S; Nathan, A M; Nikolenko, D M; Nelyubin, V; Norum, B E; Paschke, K; Pentchev, L; Perdrisat, C F; Piasetzky, E; Pomatsalyuk, R; Punjabi, V A; Rachek, I; Radyushkin, A; Reitz, B; Roche, R; Ron, G; Sabatié, F; Saha, A; Savvinov, N; Shahinyan, A; Shestakov, Y; Sirca, S; Slifer, K; Solvignon, P; Stoler, P; Tajima, S; Sulkosky, V; Todor, L; Vlahovic, B; Weinstein, L B; Wang, K; Wojtsekhowski, B; Voskanyan, H; Xiang, H; Zheng, X; Zhu, L

    2007-04-13

    Cross-section values for Compton scattering on the proton were measured at 25 kinematic settings over the range s=5-11 and -t=2-7 GeV2 with a statistical accuracy of a few percent. The scaling power for the s dependence of the cross section at fixed center-of-mass angle was found to be 8.0+/-0.2, strongly inconsistent with the prediction of perturbative QCD. The observed cross-section values are in fair agreement with the calculations using the handbag mechanism, in which the external photons couple to a single quark. PMID:17501338

  16. Compton Scattering Cross Section on the Proton at High Momentum Transfer

    SciTech Connect

    A. Danagoulian; V.H. Mamyan; M. Roedelbronn; K.A. Aniol; J.R.M. Annand; P.Y. Bertin; L. Bimbot; P. Bosted; J.R. Calarco; A. Camsonne; C.C. Chang; T.-H. Chang; J.-P. Chen; Seonho Choi; E. Chudakov; P. Degtyarenko; C.W. de Jager; A. Deur; D. Dutta; K. Egiyan; H. Gao; F. Garibaldi; O. Gayou; R. Gilman; A. Glamazdin; C. Glashausser; J. Gomez; D.J. Hamilton; J.-O. Hansen; D. Hayes; D.W. Higinbotham; W. Hinton; T. Horn; C. Howell; T. Hunyady; C.E. Hyde-Wright; X. Jiang; M.K. Jones; M. Khandaker; A. Ketikyan; V. Koubarovski; K. Kramer; G. Kumbartzki; G. Laveissiere; J. LeRose; R.A. Lindgren; D.J. Margaziotis; P. Markowitz; K. McCormick; Z.-E. Meziani; R. Michaels; P. Moussiegt; S. Nanda; A.M. Nathan; D.M. Nikolenko; V. Nelyubin; B.E. Norum; K. Paschke; L. Pentchev; C.F. Perdrisat; E. Piasetzky; R. Pomatsalyuk; V.A. Punjabi; I. Rachek; A. Radyushkin; B. Reitz; R. Roche; G. Ron; F. Sabatie; A. Saha; N. Savvinov; A. Shahinyan; Y. Shestakov; S. Sirca; K. Slifer; P. Solvignon; P. Stoler; S. Tajima; V. Sulkosky; L. Todor; B. Vlahovic; L.B. Weinstein; K. Wang; B. Wojtsekhowski; H. Voskanyan; H. Xiang; X. Zheng; L. Zhu

    2007-01-29

    Cross-section values for Compton scattering on the proton were measured at 25 kinematic settings over the range s = 5-11 and -t = 2-7 GeV2 with statistical accuracy of a few percent. The scaling power for the s-dependence of the cross section at fixed center of mass angle was found to be 8.0 +/- 0.2, strongly inconsistent with the prediction of perturbative QCD. The observed cross section values are in fair agreement with the calculations using the handbag mechanism, in which the external photons couple to a single quark.

  17. Overview of Laser Compton-Scattered Photon Source at the cERL

    NASA Astrophysics Data System (ADS)

    Nagai, R.; Hajima, R.; Kosuge, A.; Mori, M.; Shizuma, T.; Nishimori, N.; Akagi, T.; Honda, Y.; Urakawa, J.

    2015-10-01

    A high intensity γ-ray source from the laser Compton scattering (LCS) by an electron beam in the energy recovery linac (ERL) is a very useful prove for a nondestructive assay to identify nuclear species. In order to demonstrate a high performance of the accelerator and laser required for the γ-ray source, an LCS experiment is planned at the Compact ERL (cERL) at High Energy Accelerator Research Organization (KEK). A mode-locked fiber laser, laser enhancement cavity, beamline, and experimental hatch are under construction for the LCS experiment.

  18. Time evolution analysis of the electron distribution in Thomson/Compton back-scattering

    SciTech Connect

    Petrillo, V.; Bacci, A.; Curatolo, C.; Maroli, C.; Serafini, L.; Rossi, A. R.

    2013-07-28

    We present the time evolution of the energy distribution of a relativistic electron beam after the Compton back-scattering with a counter-propagating laser field, performed in the framework of the Quantum Electrodynamics, by means of the code CAIN. As the correct angular distribution of the spontaneous emission is accounted, the main effect is the formation of few stripes, followed by the diffusion of the more energetic particles toward lower values in the longitudinal phase space. The Chapman-Kolmogorov master equation gives results in striking agreement with the numerical ones. An experiment on the Thomson source at SPARC-LAB is proposed.

  19. In vivo measurement of the trabecular bone mineral density by coherent and Compton. gamma. -ray scattering

    SciTech Connect

    Karellas, A.

    1984-01-01

    A photon scattering method for measuring the mineral density of trabecular bone (BMD) is described. By computing the ratio of the coherent to Compton scattered photons, the BMD can be measured accurately and without any significant interference by the surrounding tissue. This study shows theoretically and experimentally that an increase in the scatter angle, when using 60 keV photons from Am-241, results in a stronger power dependence on Z. This implies that by increasing the scatter angle, smaller changes in BMD can be detected, thus improving the sensitivity of the measurement. The dependence of the sensitivity on the energy of the incident photons was also investigated. A collimated beam of photons from 1200 mCi of Am-241 (60 keV) was used and the scattered photons were detected at a scatter angle of 71/sup 0/. The system was calibrated by using a new standard which contains bone mineral mixed homogeneously with a marrow simulating substance. This method was applied for the measurement of the calcaneal BMD in 21 normal volunteers and seven paraplegic patients. The BMD values for the normal group ranged from 170-300 mg/cm/sup 3/. The BMD for the paraplegics with injuries older than one year ranged from 90-150 mg/cm/sup 3/. This measurement has potential application in the diagnosis of early osteopenia and in monitoring the effect of various treatment regimens.

  20. Compton scattering in strong magnetic fields: Spin-dependent influences at the cyclotron resonance

    NASA Astrophysics Data System (ADS)

    Gonthier, Peter L.; Baring, Matthew G.; Eiles, Matthew T.; Wadiasingh, Zorawar; Taylor, Caitlin A.; Fitch, Catherine J.

    2014-08-01

    The quantum electrodynamical (QED) process of Compton scattering in strong magnetic fields is commonly invoked in atmospheric and inner magnetospheric models of x-ray and soft gamma-ray emission in high-field pulsars and magnetars. A major influence of the field is to introduce resonances at the cyclotron frequency and its harmonics, where the incoming photon accesses thresholds for the creation of virtual electrons or positrons in intermediate states with excited Landau levels. At these resonances, the effective cross section typically exceeds the classical Thomson value by over 2 orders of magnitude. Near and above the quantum critical magnetic field of 44.13 TeraGauss, relativistic corrections must be incorporated when computing this cross section. This profound enhancement underpins the anticipation that resonant Compton scattering is a very efficient process in the environs of highly magnetized neutron stars. This paper presents formalism for the QED magnetic Compton differential cross section valid for both subcritical and supercritical fields, yet restricted to scattered photons that are below pair creation threshold. Calculations are developed for the particular case of photons initially propagating along the field, and in the limit of zero vacuum dispersion, mathematically simple specializations that are germane to interactions involving relativistic electrons frequently found in neutron star magnetospheres. This exposition of relativistic, quantum, magnetic Compton cross sections treats electron spin dependence fully, since this is a critical feature for describing the finite decay lifetimes of the intermediate states. Such lifetimes are introduced to truncate the resonant cyclotronic divergences via standard Lorentz profiles. The formalism employs both the traditional Johnson and Lippmann (JL) wave functions and the Sokolov and Ternov (ST) electron eigenfunctions of the magnetic Dirac equation. The ST states are formally correct for self

  1. Inverse Compton for Compton

    NASA Astrophysics Data System (ADS)

    Suortti, Pekka

    2016-04-01

    A novel concept for a high resolution Compton spectrometer is introduced. 88 keV radiation from an Inverse Compton Compact Source is focused using crossed cylindrically bent Laue-type Si perfect crystals, and dispersed on the sample with a constant energy gradient. Dispersion is compensated exactly at a Ge crystal analyzer, so that the same wavelength shift is observed for all wavelengths of the incident beam. The ThomX source is used as a concrete example. Detailed dimensions and flux estimates at successive locations of the spectrometer are given, and the performance is compared with the dispersion compensating spectrometer at ID15 of the ESRF. The momentum resolution is better than 0.1 atomic units in both cases. The intensity of scattering with the compact source is an order of magnitude smaller, but still adequate for high resolution Compton profile measurements.

  2. High-Accuracy Analysis of Compton Scattering in Chiral EFT: Proton and Neutron Polarisabilities

    NASA Astrophysics Data System (ADS)

    Griesshammer, Harald W.; Phillips, Daniel R.; McGovern, Judith A.

    2013-10-01

    Compton scattering from protons and neutrons provides important insight into the structure of the nucleon. A new extraction of the static electric and magnetic dipole polarisabilities αE 1 and βM 1 of the proton and neutron from all published elastic data below 300 MeV in Chiral Effective Field Theory shows that within the statistics-dominated errors, the proton and neutron polarisabilities are identical, i.e. no iso-spin breaking effects of the pion cloud are seen. Particular attention is paid to the precision and accuracy of each data set, and to an estimate of residual theoretical uncertainties. ChiEFT is ideal for that purpose since it provides a model-independent estimate of higher-order corrections and encodes the correct low-energy dynamics of QCD, including, for few-nucleon systems used to extract neutron polarisabilities, consistent nuclear currents, rescattering effects and wave functions. It therefore automatically respects the low-energy theorems for photon-nucleus scattering. The Δ (1232) as active degree of freedom is essential to realise the full power of the world's Compton data.Its parameters are constrained in the resonance region. A brief outlook is provided on what kind of future experiments can improve the database. Supported in part by UK STFC, DOE, NSF, and the Sino-German CRC 110.

  3. First measurement of Z/γ* production in compton scattering of quasi-real photons

    NASA Astrophysics Data System (ADS)

    OPAL Collaboration; Abbiendi, G.; Ackerstaff, K.; Alexander, G.; Allison, J.; Altekamp, N.; Anderson, K. J.; Anderson, S.; Arcelli, S.; Asai, S.; Ashby, S. F.; Axen, D.; Azuelos, G.; Ball, A. H.; Barberio, E.; Barlow, R. J.; Bartoldus, R.; Batley, J. R.; Baumann, S.; Bechtluft, J.; Behnke, T.; Bell, K. W.; Bella, G.; Bellerive, A.; Bentvelsen, S.; Bethke, S.; Betts, S.; Biebel, O.; Biguzzi, A.; Bird, S. D.; Blobel, V.; Bloodworth, I. J.; Bobinski, M.; Bock, P.; Böhme, J.; Bonacorsi, D.; Boutemeur, M.; Braibant, S.; Bright-Thomas, P.; Brigliadori, L.; Brown, R. M.; Burckhart, H. J.; Burgard, C.; Bürgin, R.; Capiluppi, P.; Carnegie, R. K.; Carter, A. A.; Carter, J. R.; Chang, C. Y.; Charlton, D. G.; Chrisman, D.; Ciocca, C.; Clarke, P. E. L.; Clay, E.; Cohen, I.; Conboy, J. E.; Cooke, O. C.; Couyoumtzelis, C.; Coxe, R. L.; Cuffiani, M.; Dado, S.; Dallavalle, G. M.; Davis, R.; de Jong, S.; del Pozo, L. A.; de Roeck, A.; Desch, K.; Dienes, B.; Dixit, M. S.; Dubbert, J.; Duchovni, E.; Duckeck, G.; Duerdoth, I. P.; Eatough, D.; Estabrooks, P. G.; Etzion, E.; Evans, H. G.; Fabbri, F.; Fanti, M.; Faust, A. A.; Fiedler, F.; Fierro, M.; Fleck, I.; Folman, R.; Fürtjes, A.; Futyan, D. I.; Gagnon, P.; Gary, J. W.; Gascon, J.; Gascon-Shotkin, S. M.; Gaycken, G.; Geich-Gimbel, C.; Giacomelli, G.; Giacomelli, P.; Gibson, V.; Gibson, W. R.; Gingrich, D. M.; Glenzinski, D.; Goldberg, J.; Gorn, W.; Grandi, C.; Gross, E.; Grunhaus, J.; Gruwé, M.; Hanson, G. G.; Hansroul, M.; Hapke, M.; Harder, K.; Hargrove, C. K.; Hartmann, C.; Hauschild, M.; Hawkes, C. M.; Hawkings, R.; Hemingway, R. J.; Herndon, M.; Herten, G.; Heuer, R. D.; Hildreth, M. D.; Hill, J. C.; Hillier, S. J.; Hobson, P. R.; Hocker, A.; Homer, R. J.; Honma, A. K.; Horváth, D.; Hossain, K. R.; Howard, R.; Hüntemeyer, P.; Igo-Kemenes, P.; Imrie, D. C.; Ishii, K.; Jacob, F. R.; Jawahery, A.; Jeremie, H.; Jimack, M.; Jones, C. R.; Jovanovic, P.; Junk, T. R.; Karlen, D.; Kartvelishvili, V.; Kawagoe, K.; Kawamoto, T.; Kayal, P. I.; Keeler, R. K.; Kellogg, R. G.; Kennedy, B. W.; Klier, A.; Kluth, S.; Kobayashi, T.; Kobel, M.; Koetke, D. S.; Kokott, T. P.; Kolrep, M.; Komamiya, S.; Kowalewski, R. V.; Kress, T.; Krieger, P.; von Krogh, J.; Kuhl, T.; Kyberd, P.; Lafferty, G. D.; Lanske, D.; Lauber, J.; Lautenschlager, S. R.; Lawson, I.; Layter, J. G.; Lazic, D.; Lee, A. M.; Lellouch, D.; Letts, J.; Levinson, L.; Liebisch, R.; List, B.; Littlewood, C.; Lloyd, A. W.; Lloyd, S. L.; Loebinger, F. K.; Long, G. D.; Losty, M. J.; Ludwig, J.; Liu, D.; Macchiolo, A.; MacPherson, A.; Mader, W.; Mannelli, M.; Marcellini, S.; Markopoulos, C.; Martin, A. J.; Martin, J. P.; Martinez, G.; Mashimo, T.; Mättig, P.; McDonald, W. J.; McKenna, J.; McKigney, E. A.; McMahon, T. J.; McPherson, R. A.; Meijers, F.; Menke, S.; Merritt, F. S.; Mes, H.; Meyer, J.; Michelini, A.; Mihara, S.; Mikenberg, G.; Miller, D. J.; Mir, R.; Mohr, W.; Montanari, A.; Mori, T.; Nagai, K.; Nakamura, I.; Neal, H. A.; Nellen, B.; Nisius, R.; O'Neale, S. W.; Oakham, F. G.; Odorici, F.; Ogren, H. O.; Oreglia, M. J.; Orito, S.; Pálinkás, J.; Pásztor, G.; Pater, J. R.; Patrick, G. N.; Patt, J.; Perez-Ochoa, R.; Petzold, S.; Pfeifenschneider, P.; Pilcher, J. E.; Pinfold, J.; Plane, D. E.; Poffenberger, P.; Polok, J.; Przybycień , M.; Rembser, C.; Rick, H.; Robertson, S.; Robins, S. A.; Rodning, N.; Roney, J. M.; Roscoe, K.; Rossi, A. M.; Rozen, Y.; Runge, K.; Runolfsson, O.; Rust, D. R.; Sachs, K.; Saeki, T.; Sahr, O.; Sang, W. M.; Sarkisyan, E. K. G.; Sbarra, C.; Schaile, A. D.; Schaile, O.; Scharf, F.; Scharff-Hansen, P.; Schieck, J.; Schmitt, B.; Schmitt, S.; Schöning, A.; Schröder, M.; Schumacher, M.; Schwick, C.; Scott, W. G.; Seiler, T.; Seuster, R.; Shears, T. G.; Shen, B. C.; Shepherd-Themistocleous, C. H.; Sherwood, P.; Siroli, G. P.; Sittler, A.; Skuja, A.; Smith, A. M.; Snow, G. A.; Sobie, R.; Söldner-Rembold, S.; Sproston, M.; Stahl, A.; Stephens, K.; Steuerer, J.; Stoll, K.; Strom, D.; Ströhmer, R.; Surrow, B.; Talbot, S. D.; Tanaka, S.; Taras, P.; Tarem, S.; Teuscher, R.; Thiergen, M.; Thomson, M. A.; von Törne, E.; Torrence, E.; Towers, S.; Trigger, I.; Trócsányi, Z.; Tsur, E.; Turcot, A. S.; Turner-Watson, M. F.; van Kooten, R.; Vannerem, P.; Verzocchi, M.; Voss, H.; Wäckerle, F.; Wagner, A.; Ward, C. P.; Ward, D. R.; Watkins, P. M.; Watson, A. T.; Watson, N. K.; Wells, P. S.; Wermes, N.; White, J. S.; Wilson, G. W.; Wilson, J. A.; Wyatt, T. R.; Yamashita, S.; Yekutieli, G.; Zacek, V.; Zer-Zion, D.

    1998-10-01

    We report the first observation of Z/γ* production in Compton scattering of quasi-real photons. This is a subprocess of the reaction e+e--->e+e- Z/γ*, where one of the final state electrons is undetected. Approximately 55 pb-1 of data collected in the year 1997 at an e+e- centre-of-mass energy of 183 GeV with the OPAL detector at LEP have been analysed. The Z/γ* from Compton scattering has been detected in the hadronic decay channel. Within well defined kinematic bounds, we measure the product of cross-section and Z/γ* branching ratio to hadrons to be (0.9+/-0.3+/-0.1) pb for events with a hadronic mass larger than 60 GeV, dominated by (e)eZ production. In the hadronic mass region between 5 GeV and 60 GeV, dominated by (e)eγ* production, this product is found to be (4.1+/-1.6+/-0.6) pb. Our results agree with the predictions of two Monte Carlo event generators, grc4f and PYTHIA.

  4. Precision 0.5 GW X-band rf system for advanced Compton scattering source

    NASA Astrophysics Data System (ADS)

    Chu, T. S.; Anderson, G.; Gibson, D.; Hartemann, F. V.; Barty, C. P. J.; Vlieks, A.; Tantawi, S.; Jongewaard, E.; Anderson, S. G.

    2009-11-01

    A Mono-Energetic Gamma-Ray (MEGa-Ray) Compton scattering light source is being developed at LLNL. The electron beam for the Compton scattering interaction will be generated by a X-band RF gun and a X-band LINAC at the frequency of 11.424 GHz. High power RF in excess of 500 MW is needed to accelerate the electrons to energy of 250 MeV or greater for the interaction. Two high power klystron amplifiers, each capable of generating 50 MW, 1.5 msec pulses, will be the main high power RF sources for the system. These klystrons will be powered by state of the art solid-state high voltage modulators. A RF pulse compressor, similar to the SLED II pulse compressor, will compress the klystron output pulse with a power gain factor of five. This will give us 500 MW (0.5 GW) at output of the compressor. The compressed pulse will then be distributed to the RF gun and to the LINAC with specific phase and amplitude control points to allow for parameter control during operation. This high power RF system is being designed and constructed. In this paper, we will present the design, layout, and status of this RF system.

  5. Stability analysis of implicit time discretizations for the Compton-scattering Fokker-Planck equation

    SciTech Connect

    Densmore, Jeffery D. Warsa, James S. Lowrie, Robert B. Morel, Jim E.

    2009-09-01

    The Fokker-Planck equation is a widely used approximation for modeling the Compton scattering of photons in high energy density applications. In this paper, we perform a stability analysis of three implicit time discretizations for the Compton-Scattering Fokker-Planck equation. Specifically, we examine (i) a Semi-Implicit (SI) scheme that employs backward-Euler differencing but evaluates temperature-dependent coefficients at their beginning-of-time-step values, (ii) a Fully Implicit (FI) discretization that instead evaluates temperature-dependent coefficients at their end-of-time-step values, and (iii) a Linearized Implicit (LI) scheme, which is developed by linearizing the temperature dependence of the FI discretization within each time step. Our stability analysis shows that the FI and LI schemes are unconditionally stable and cannot generate oscillatory solutions regardless of time-step size, whereas the SI discretization can suffer from instabilities and nonphysical oscillations for sufficiently large time steps. With the results of this analysis, we present time-step limits for the SI scheme that prevent undesirable behavior. We test the validity of our stability analysis and time-step limits with a set of numerical examples.

  6. Stability analysis of implicit time discretizations for the Compton-scattering Fokker-Planck equation

    SciTech Connect

    Densmore, Jeffery D; Warsa, James S; Lowrie, Robert B; Morel, Jim E

    2008-01-01

    The Fokker-Planck equation is a widely used approximation for modeling the Compton scattering of photons in high energy density applications. In this paper, we perform a stability analysis of three implicit time discretizations for the Compton-Scattering Fokker-Planck equation. Specifically, we examine (i) a Semi-Implicit (SI) scheme that employs backward-Euler differencing but evaluates temperature-dependent coefficients at their beginning-of-time-step values, (ii) a Fully Implicit (FI) discretization that instead evaluates temperature-dependent coefficients at their end-of-time-step values, and (iii) a Linearized Implicit (LI) scheme, which is developed by linearizing the temperature dependence of the FI discretization within each time step. Our stability analysis shows that the FI and LI schemes are unconditionally stable and cannot generate oscillatory solutions regardless of time-step size, whereas the SI discretization can suffer from instabilities and nonphysical oscillations for sufficiently large time steps. With the results of this analysis, we present time-step limits for the SI scheme that prevent undesirable behavior. We test the validity of our stability analysis and time-step limits with a set of numerical examples.

  7. Data acquisition and analysis for the energy-subtraction Compton scatter camera for medical imaging

    NASA Astrophysics Data System (ADS)

    Khamzin, Murat Kamilevich

    In response to the shortcomings of the Anger camera currently being used in conventional SPECT, particularly the trade-off between sensitivity and spatial resolution, a novel energy-subtraction Compton scatter camera, or the ESCSC, has been proposed. A successful clinical implementation of the ESCSC could revolutionize the field of SPECT. Features of this camera include utilization of silicon and CdZnTe detectors in primary and secondary detector systems, list-mode time stamping data acquisition, modular architecture, and post-acquisition data analysis. Previous ESCSC studies were based on Monte Carlo modeling. The objective of this work is to test the theoretical framework developed in previous studies by developing the data acquisition and analysis techniques necessary to implement the ESCSC. The camera model working in list-mode with time stamping was successfully built and tested thus confirming potential of the ESCSC that was predicted in previous simulation studies. The obtained data were processed during the post-acquisition data analysis based on preferred event selection criteria. Along with the construction of a camera model and proving the approach, the post-acquisition data analysis was further extended to include preferred event weighting based on the likelihood of a preferred event to be a true preferred event. While formulated to show ESCSC capabilities, the results of this study are important for any Compton scatter camera implementation as well as for coincidence data acquisition systems in general.

  8. Measurements of Double-Polarized Compton Scattering Asymmetries and Extraction of the Proton Spin Polarizabilities

    NASA Astrophysics Data System (ADS)

    Martel, P. P.; Miskimen, R.; Aguar-Bartolome, P.; Ahrens, J.; Akondi, C. S.; Annand, J. R. M.; Arends, H. J.; Barnes, W.; Beck, R.; Bernstein, A.; Borisov, N.; Braghieri, A.; Briscoe, W. J.; Cherepnya, S.; Collicott, C.; Costanza, S.; Denig, A.; Dieterle, M.; Downie, E. J.; Fil'kov, L. V.; Garni, S.; Glazier, D. I.; Gradl, W.; Gurevich, G.; Hall Barrientos, P.; Hamilton, D.; Hornidge, D.; Howdle, D.; Huber, G. M.; Jude, T. C.; Kaeser, A.; Kashevarov, V. L.; Keshelashvili, I.; Kondratiev, R.; Korolija, M.; Krusche, B.; Lazarev, A.; Lisin, V.; Livingston, K.; MacGregor, I. J. D.; Mancell, J.; Manley, D. M.; Meyer, W.; Middleton, D. G.; Mushkarenkov, A.; Nefkens, B. M. K.; Neganov, A.; Nikolaev, A.; Oberle, M.; Ortega Spina, H.; Ostrick, M.; Ott, P.; Otte, P. B.; Oussena, B.; Pedroni, P.; Polonski, A.; Polyansky, V.; Prakhov, S.; Rajabi, A.; Reicherz, G.; Rostomyan, T.; Sarty, A.; Schrauf, S.; Schumann, S.; Sikora, M. H.; Starostin, A.; Steffen, O.; Strakovsky, I. I.; Strub, T.; Supek, I.; Thiel, M.; Tiator, L.; Thomas, A.; Unverzagt, M.; Usov, Y.; Watts, D. P.; Witthauer, L.; Werthmüller, D.; Wolfes, M.; A2 Collaboration at MAMI

    2015-03-01

    The spin polarizabilities of the nucleon describe how the spin of the nucleon responds to an incident polarized photon. The most model-independent way to extract the nucleon spin polarizabilities is through polarized Compton scattering. Double-polarized Compton scattering asymmetries on the proton were measured in the Δ (1232 ) region using circularly polarized incident photons and a transversely polarized proton target at the Mainz Microtron. Fits to asymmetry data were performed using a dispersion model calculation and a baryon chiral perturbation theory calculation, and a separation of all four proton spin polarizabilities in the multipole basis was achieved. The analysis based on a dispersion model calculation yields γE 1 E 1=-3.5 ±1.2 , γM 1 M 1=3.16 ±0.85 , γE 1 M 2=-0.7 ±1.2 , and γM 1 E 2=1.99 ±0.29 , in units of 1 0-4 fm4 .

  9. Testing Models of Resonant Compton Scattering in X-Ray Pulsars

    NASA Technical Reports Server (NTRS)

    Brainerd, Jerome J.

    2000-01-01

    Over the performance period covered by the grant, the principal investigator modified a Monte Carlo Compton scattering code to model the propagation of x-rays through the magnetosphere of accreting neutron stars. These modifications were made to enable the author to compare the observations of x-ray pulsars to theoretical models of the system. The original code was designed to study relativistic plasmas with one of two geometries: a plane parallel plasma with a differential relativistic bulk velocity, and a static spherically symmetric plasma.- This code did not treat gravitational bending or bulk motion in the magnetosphere of a neutron star. Under the grant, the author incorporated code to trace light paths in a Schwarzschild metric. The code was modified to keep track of the photon polarization during propagati on. The investigator also modified the code so that bulk motion in an axisymmetric system is treated properly. An approximate treatment for resonant Compton scattering was added to the code. Finally, code was added that creates model observables that can be compared to observations, such as projected x-ray emission maps and energy-dependent light curves. Comparison to observations is now commencing.

  10. Towards direct reconstruction from a gamma camera based on compton scattering

    SciTech Connect

    Cree, M.J.; Bones, P.J. . Dept. of Electrical and Electronic Engineering)

    1994-06-01

    The Compton scattering camera (sometimes called the electronically collimated camera) has been shown by others to have the potential to better the photon counting statistics and the energy resolution of the Anger camera for imaging in SPECT. By using coincident detection of Compton scattering events on two detecting planes, a photon can be localized to having been sourced on the surface of a cone. New algorithms are needed to achieve fully three-dimensional reconstruction of the source distribution from such a camera. If a complete set of cone-surface projections are collected over an infinitely extending plane, it is shown that the reconstruction problem is not only analytically solvable, but also overspecified in the absence of measurement uncertainties. Two approaches to direct reconstruction are proposed, both based on the photons which travel perpendicularly between the detector planes. Results of computer simulations are presented which demonstrate the ability of the algorithms to achieve useful reconstructions in the absence of measurement uncertainties (other than those caused by quantization). The modifications likely to be required in the presence of realistic measurement uncertainties are discussed.

  11. Compton scattering S matrix and cross section in strong magnetic field

    NASA Astrophysics Data System (ADS)

    Mushtukov, Alexander A.; Nagirner, Dmitrij I.; Poutanen, Juri

    2016-05-01

    Compton scattering of polarized radiation in a strong magnetic field is considered. The recipe for calculation of the scattering matrix elements, the differential and total cross sections based on quantum electrodynamic second-order perturbation theory is presented for the case of arbitrary initial and final Landau level, electron momentum along the field and photon momentum. Photon polarization and electron spin state are taken into account. The correct dependence of natural Landau level width on the electron spin state is taken into account in a general case of arbitrary initial photon momentum for the first time. A number of steps in the calculations were simplified analytically making the presented recipe easy to use. The redistribution functions over the photon energy, momentum and polarization states are presented and discussed. The paper generalizes already known results and offers a basis for the accurate calculation of radiation transfer in a strong B field, for example, in strongly magnetized neutron stars.

  12. Attenuation studies near K-absorption edges using Compton scattered 241 Am gamma rays

    NASA Astrophysics Data System (ADS)

    Abdullah, K. K.; Ramachandran, N.; Karunakaran Nair, K.; Babu, B. R. S.; Joseph, Antony; Thomas, Rajive; Varier, K. M.

    2008-04-01

    We have carried out photon attenuation measurements at several energies in the range from 49.38 keV to 57.96 keV around the K-absorption edges of the rare earth elements Sm, Eu, Gd, Tb, Dy and Er using 59.54 keV gamma rays from ^{241}Am source after Compton scattering from an aluminium target. Pellets of oxides of the rare earth elements were chosen as mixture absorbers in these investigations. A narrow beam good geometry set-up was used for the attenuation measurements. The scattered gamma rays were detected by an HPGe detector. The results are consistent with theoretical values derived from the XCOM package.

  13. Measurement of the proton structure function F2 at low Q2 in QED Compton scattering at HERA

    NASA Astrophysics Data System (ADS)

    Aktas, A.; Andreev, V.; Anthonis, T.; Asmone, A.; Babaev, A.; Backovic, S.; Bähr, J.; Baranov, P.; Barrelet, E.; Bartel, W.; Baumgartner, S.; Becker, J.; Beckingham, M.; Behnke, O.; Behrendt, O.; Belousov, A.; Berger, Ch.; Berger, N.; Berndt, T.; Bizot, J. C.; Böhme, J.; Boenig, M.-O.; Boudry, V.; Bracinik, J.; Brisson, V.; Bröker, H.-B.; Brown, D. P.; Bruncko, D.; Büsser, F. W.; Bunyatyan, A.; Buschhorn, G.; Bystritskaya, L.; Campbell, A. J.; Caron, S.; Cassol-Brunner, F.; Cerny, K.; Chekelian, V.; Collard, C.; Contreras, J. G.; Coppens, Y. R.; Coughlan, J. A.; Cox, B. E.; Cozzika, G.; Cvach, J.; Dainton, J. B.; Dau, W. D.; Daum, K.; Delcourt, B.; Demirchyan, R.; De Roeck, A.; Desch, K.; De Wolf, E. A.; Diaconu, C.; Dingfelder, J.; Dodonov, V.; Dubak, A.; Duprel, C.; Eckerlin, G.; Efremenko, V.; Egli, S.; Eichler, R.; Eisele, F.; Ellerbrock, M.; Elsen, E.; Erdmann, M.; Erdmann, W.; Faulkner, P. J. W.; Favart, L.; Fedotov, A.; Felst, R.; Ferencei, J.; Fleischer, M.; Fleischmann, P.; Fleming, Y. H.; Flucke, G.; Flügge, G.; Fomenko, A.; Foresti, I.; Formánek, J.; Franke, G.; Frising, G.; Gabathuler, E.; Gabathuler, K.; Garutti, E.; Garvey, J.; Gayler, J.; Gerhards, R.; Gerlich, C.; Ghazaryan, S.; Goerlich, L.; Gogitidze, N.; Gorbounov, S.; Grab, C.; Grässler, H.; Greenshaw, T.; Gregori, M.; Grindhammer, G.; Gwilliam, C.; Haidt, D.; Hajduk, L.; Haller, J.; Hansson, M.; Heinzelmann, G.; Henderson, R. C. W.; Henschel, H.; Henshaw, O.; Heremans, R.; Herrera, G.; Herynek, I.; Heuer, R.-D.; Hildebrandt, M.; Hiller, K. H.; Höting, P.; Hoffmann, D.; Horisberger, R.; Hovhannisyan, A.; Ibbotson, M.; Ismail, M.; Jacquet, M.; Janauschek, L.; Janssen, X.; Jemanov, V.; Jönsson, L.; Johnson, D. P.; Jung, H.; Kant, D.; Kapichine, M.; Karlsson, M.; Katzy, J.; Keller, N.; Kennedy, J.; Kenyon, I. R.; Kiesling, C.; Klein, M.; Kleinwort, C.; Klimkovich, T.; Kluge, T.; Knies, G.; Knutsson, A.; Koblitz, B.; Korbel, V.; Kostka, P.; Koutouev, R.; Kropivnitskaya, A.; Kroseberg, J.; Kückens, J.; Kuhr, T.; Landon, M. P. J.; Lange, W.; Laštovička, T.; Laycock, P.; Lebedev, A.; Leißner, B.; Lemrani, R.; Lendermann, V.; Levonian, S.; Lindfeld, L.; Lipka, K.; List, B.; Lobodzinska, E.; Loktionova, N.; Lopez-Fernandez, R.; Lubimov, V.; Lueders, H.; Lüke, D.; Lux, T.; Lytkin, L.; Makankine, A.; Malden, N.; Malinovski, E.; Mangano, S.; Marage, P.; Marks, J.; Marshall, R.; Martisikova, M.; Martyn, H.-U.; Maxfield, S. J.; Meer, D.; Mehta, A.; Meier, K.; Meyer, A. B.; Meyer, H.; Meyer, J.; Michine, S.; Mikocki, S.; Milcewicz-Mika, I.; Milstead, D.; Mohamed, A.; Moreau, F.; Morozov, A.; Morozov, I.; Morris, J. V.; Mozer, M. U.; Müller, K.; Murín, P.; Nagovizin, V.; Naroska, B.; Naumann, J.; Naumann, Th.; Newman, P. R.; Niebuhr, C.; Nikiforov, A.; Nikitin, D.; Nowak, G.; Nozicka, M.; Oganezov, R.; Olivier, B.; Olsson, J. E.; Ossoskov, G.; Ozerov, D.; Pascaud, C.; Patel, G. D.; Peez, M.; Perez, E.; Perieanu, A.; Petrukhin, A.; Pitzl, D.; Plačakytė, R.; Pöschl, R.; Portheault, B.; Povh, B.; Raicevic, N.; Ratiani, Z.; Reimer, P.; Reisert, B.; Rimmer, A.; Risler, C.; Rizvi, E.; Robmann, P.; Roland, B.; Roosen, R.; Rostovtsev, A.; Rurikova, Z.; Rusakov, S.; Rybicki, K.; Sankey, D. P. C.; Sauvan, E.; Schätzel, S.; Scheins, J.; Schilling, F.-P.; Schleper, P.; Schmidt, S.; Schmitt, S.; Schneider, M.; Schoeffel, L.; Schöning, A.; Schröder, V.; Schultz-Coulon, H.-C.; Schwanenberger, C.; Sedlák, K.; Sefkow, F.; Sheviakov, I.; Shtarkov, L. N.; Sirois, Y.; Sloan, T.; Smirnov, P.; Soloviev, Y.; South, D.; Spaskov, V.; Specka, A.; Spitzer, H.; Stamen, R.; Stella, B.; Stiewe, J.; Strauch, I.; Straumann, U.; Tchoulakov, V.; Thompson, G.; Thompson, P. D.; Tomasz, F.; Traynor, D.; Truöl, P.; Tsipolitis, G.; Tsurin, I.; Turnau, J.; Tzamariudaki, E.; Uraev, A.; Urban, M.; Usik, A.; Utkin, D.; Valkár, S.; Valkárová, A.; Vallée, C.; Van Mechelen, P.; Van Remortel, N.; Vargas Trevino, A.; Vazdik, Y.; Veelken, C.; Vest, A.; Vinokurova, S.; Volchinski, V.; Wacker, K.; Wagner, J.; Weber, G.; Weber, R.; Wegener, D.; Werner, C.; Werner, N.; Wessels, M.; Wessling, B.; Winter, G.-G.; Wissing, Ch.; Woehrling, E.-E.; Wolf, R.; Wünsch, E.; Xella, S.; Yan, W.; Yeganov, V.; Žáček, J.; Zálešák, J.; Zhang, Z.; Zhokin, A.; Zohrabyan, H.; Zomer, F.; H1 Collaboration

    2004-09-01

    The proton structure function F2 (x,Q2) is measured in inelastic QED Compton scattering using data collected with the H1 detector at HERA. QED Compton events are used to access the kinematic range of very low virtualities of the exchanged photon, Q2, down to 0.5 GeV2, and Bjorken x up to ∼0.06, a region which has not been covered previously by inclusive measurements at HERA. The results are in agreement with the measurements from fixed target lepton-nucleon scattering experiments.

  14. Compton scattering for spectroscopic detection of ultra-fast, high flux, broad energy range X-rays

    SciTech Connect

    Cipiccia, S.; Wiggins, S. M.; Brunetti, E.; Vieux, G.; Yang, X.; Welsh, G. H.; Anania, M.; Islam, M. R.; Ersfeld, B.; Jaroszynski, D. A.; Maneuski, D.; Montgomery, R.; Smith, G.; Hoek, M.; Hamilton, D. J.; Shea, V. O.; Issac, R. C.; Lemos, N. R. C.; Dias, J. M.; and others

    2013-11-15

    Compton side-scattering has been used to simultaneously downshift the energy of keV to MeV energy range photons while attenuating their flux to enable single-shot, spectrally resolved, measurements of high flux X-ray sources to be undertaken. To demonstrate the technique a 1 mm thick pixelated cadmium telluride detector has been used to measure spectra of Compton side-scattered radiation from a Cobalt-60 laboratory source and a high flux, high peak brilliance X-ray source of betatron radiation from a laser-plasma wakefield accelerator.

  15. Femtosecond laser clocked compact X-band high gradient photoinjector and accelerator for Compton scattering

    NASA Astrophysics Data System (ADS)

    Destefano, Christopher A.

    High brightness and low emittance electron beams have found application throughout a variety of scientific research. The ability to produce such beams in the MeV range has previously been restricted to National Laboratory size facilities. While these sources have been successful, the reduction in size could provide valuable access for further scientific endeavors. One such application is the production of monochromatic x-rays through Compton scattering with a high intensity laser pulse. These x-rays would be tunable from 10 keV to more than 100 keV. A compact source of synchrotron type radiation capable of installation in medical institutions would be desirable for further investigation. A combination of X-band microwave and vacuum technologies developed at the Stanford Linear Accelerator Center (SLAC) was assembled. The system uses a pair of X-band klystrons. The first provides the microwave drive power for a 5.5 cell RF gun capable of operating with an accelerating gradient of 200 MV/m. Following the RF gun is a 1.05 m linac capable of accelerating the electron bunches to over 60 MeV with an energy spread of less than 1%. Using a novel frequency selection scheme a Titantium:Sapphire femtosecond laser oscillator serves as both the master clock for the microwave components and optical seed for the following amplifiers. This insures the tabletop laser amplifiers are inherently synchronized to the RF sources. A regenerative amplifier provides the first boost in energy. Half of the output is used for producing UV light for photo injection of the RF gun. The other half is sent to a multi-pass amplifier capable of producing 100 mJ pulses compressed to 50 fs for the Compton scattering. This interaction laser is then focused inside the electron beam vacuum system. The final timing between the optical pulses and the electron beam is achieved with a physical delay line placed after the final amplifier compressor. Background Bremsstrahlung radiation due to interception of

  16. THE VERY HIGH ENERGY EMISSION FROM PULSARS: A CASE FOR INVERSE COMPTON SCATTERING

    SciTech Connect

    Lyutikov, Maxim; Otte, Nepomuk; McCann, Andrew

    2012-07-20

    The observations of gamma-ray emission from pulsars with the Fermi-LAT detector and the detection of the Crab pulsar with the VERITAS array of Cherenkov telescopes at energies above 100 GeV make it unlikely that curvature radiation is the main source of photons above GeV energies in the Crab and many other pulsars. We outline a model in which the broad UV-X-ray component and the very high energy {gamma}-ray emission of pulsars are explained within the synchrotron self-Compton framework. We argue that the bulk of the observed radiation is generated by the secondary plasma, which is produced in cascades in the outer gaps of the magnetosphere. We find that the inverse Compton (IC) scattering occurs in the Klein-Nishina regime, which favors synchrotron photons in the UV band as target field for the scattering process. The primary beam is accelerated in a modest electric field, with a field strength that is of the order of a few percent of the magnetic field near the light cylinder. Overall, for IC scattering occurring in the Klein-Nishina regime, the particle distribution in the gap does not evolve toward a stationary distribution and thus is intrinsically time-dependent. We point out that in a radiation reaction-limited regime of particle acceleration the gamma-ray luminosity L{sub {gamma}} scales linearly with the pulsar spin-down power E-dot , L{sub {gamma}}{proportional_to} E-dot , and not proportional to {radical}( E-dot ) as expected from potential-limited acceleration.

  17. A Monte Carlo correction for the effect of Compton scattering in 3-D PET brain imaging

    SciTech Connect

    Levin, C.S.; Dahlbom, M.; Hoffman, E.J.

    1995-08-01

    A Monte Carlo simulation has been developed to simulate and correct for the effect of Compton scatter in 3-D acquired PET brain scans. The method utilizes the 3-D reconstructed image volume as the source intensity distribution for a photon-tracking Monte Carlo simulation. It is assumed that the number of events in each pixel of the image represents the isotope concentration at that location in the brain. The history of each annihilation photon`s interactions in the scattering medium is followed, and the sinograms for the scattered and unscattered photon pairs are generated in a simulated 3-D PET acquisition. The calculated scatter contribution is used to correct the original data set. The method is general and can be applied to any scanner configuration or geometry. In its current form the simulation requires 25 hours on a single Sparc 10 CPU when every pixel in a 15-plane, 128 x 128 pixel image volume is sampled, and less than 2 hours when 16 pixels (4 x 4) are grouped as a single pixel. Results of the correction applied to 3-D human and phantom studies are presented.

  18. Influence of electron-neutral collisions on the Compton scattering cross section and the Salpeter structure factor in warm collisional plasmas

    NASA Astrophysics Data System (ADS)

    Song, Mi-Young; Yoon, Jung-Sik; Jung, Young-Dae

    2015-03-01

    The electron-neutral collision effects on the Compton scattering process are investigated in warm collisional plasmas. The Compton scattering cross section in warm collisional plasmas is obtained by the Salpeter structure factor with the fluctuation-dissipation theorem and the plasma dielectric function as a function of the electron-neutral collision frequency, Debye length, and wave number. It is shown that the influence of electron-neutral collision strongly suppresses the Compton scattering cross section in warm collisional plasmas. It is also found that the electron-neutral collision effect on the differential Compton scattering cross section is more significant in forward scattering directions. We show that the differential Compton scattering cross section has a maximum at the scattering angle φ = π / 2 . In addition, we find that the electron-neutral collision effect on the total Compton scattering cross section increases with increasing Debye length and wave number. The variation of the Compton scattering cross section due to the change of collision frequency and plasma parameters is also discussed.

  19. Influence of electron-neutral collisions on the Compton scattering cross section and the Salpeter structure factor in warm collisional plasmas

    SciTech Connect

    Song, Mi-Young; Yoon, Jung-Sik; Jung, Young-Dae

    2015-03-15

    The electron-neutral collision effects on the Compton scattering process are investigated in warm collisional plasmas. The Compton scattering cross section in warm collisional plasmas is obtained by the Salpeter structure factor with the fluctuation-dissipation theorem and the plasma dielectric function as a function of the electron-neutral collision frequency, Debye length, and wave number. It is shown that the influence of electron-neutral collision strongly suppresses the Compton scattering cross section in warm collisional plasmas. It is also found that the electron-neutral collision effect on the differential Compton scattering cross section is more significant in forward scattering directions. We show that the differential Compton scattering cross section has a maximum at the scattering angle φ=π/2. In addition, we find that the electron-neutral collision effect on the total Compton scattering cross section increases with increasing Debye length and wave number. The variation of the Compton scattering cross section due to the change of collision frequency and plasma parameters is also discussed.

  20. Virtual compton scattering at low energy and the generalized polarizabilities of the nucleon

    SciTech Connect

    Helene Fonvieille

    2003-10-01

    We present a particular kind of (e, e' p) experiments, which has opened a new field of investigation of nucleon structure in the last ten years. The exclusive photon electroproduction process p(e, e' p){gamma} is used to study Virtual Compton Scattering (VCS) off the proton: {gamma}*p {yields} {gamma}p. In the low energy domain, this process gives access to new observables called the Generalized Polarizabilities. They are fundamental properties of the nucleon, characterizing the deformation of its internal structure under an applied electromagnetic field. Dedicated experiments have been performed at MAMI, Jefferson Lab and MIT-Bates. This contribution summarizes the results obtained so far and future prospects in the field.

  1. Detection of radioactive isotopes by using laser Compton scattered γ-ray beams

    NASA Astrophysics Data System (ADS)

    Hajima, R.; Kikuzawa, N.; Nishimori, N.; Hayakawa, T.; Shizuma, T.; Kawase, K.; Kando, M.; Minehara, E.; Toyokawa, H.; Ohgaki, H.

    2009-09-01

    Non-destructive detection and assay of nuclear materials is one of the most critical issues for both the management of nuclear waste and the non-proliferation of nuclear materials. We use laser Compton scattered (LCS) γ-ray beams and the nuclear resonance fluorescence (NRF) for the non-destructive detection of radioactive materials. Quasi-monochromatic and energy-tunable LCS γ-ray beams help improve the signal-to-noise ratio during NRF measurements. We developed the conceptual design of a high-flux γ-ray source with an energy-recovery linac, which produces a γ-ray beam at the flux of 1013 photons/s. In this paper, we discuss the execution of simulation studies using a Monte Carlo code, results of a proof-of-principle experiment for isotope detection, and the status of the development of LCS X-ray and γ-ray facilities.

  2. Compton back scatter imaging for mild steel rebar detection and depth characterization embedded in concrete

    NASA Astrophysics Data System (ADS)

    Margret, M.; Menaka, M.; Venkatraman, B.; Chandrasekaran, S.

    2015-01-01

    A novel non-destructive Compton scattering technique is described to ensure the feasibility, reliability and applicability of detecting the reinforcing steel bar in concrete. The indigenously developed prototype system presented in this paper is capable of detecting the reinforcement of varied diameters embedded in the concrete and as well as up to 60 mm depth, with the aid of Caesium-137(137Cs) radioactive source and a high resolution HPGe detector. The technique could also detect the inhomogeneities present in the test specimen by interpreting the material density variation caused due to the count rate. The experimental results are correlated using established techniques such as radiography and rebar locators. The results obtained from its application to locate the rebars are quite promising and also been successfully used for reinforcement mapping. This method can be applied, especially when the intrusion is located underneath the cover of the concrete or considerably at larger depths and where two sided access is restricted.

  3. Evidence for a narrow N{sup *}(1685) resonance in quasifree Compton scattering on the neutron

    SciTech Connect

    Kuznetsov, V.; Polyakov, M. V.; Bellini, V.; Giusa, A.; Mammoliti, F.; Randieri, C.; Russo, G.; Sperduto, M. L.; Boiko, T.; Chebotaryov, S.; Dho, H.-S.; Kim, W.; Milman, E.; Ni, A.; Gervino, G.; Ghio, F.; Kim, A.; Perevalova, I. A.; Vall, A. N.; Sutera, C. M.

    2011-02-15

    The study of quasifree Compton scattering on the neutron in the energy range of E{sub {gamma}}=0.75-1.5 GeV is presented. The data reveal a narrow peak at W{approx}1.685 GeV. This result, being considered in conjunction with the recent evidence for a narrow structure at W{approx}1.68 GeV in {eta} photoproduction on the neutron, suggests the existence of a nucleon resonance with unusual properties: a mass M{approx}1.685 GeV, a narrow width {Gamma}{<=}30 MeV, and the much stronger photoexcitation on the neutron than on the proton.

  4. Attosecond Gamma-Ray Pulses via Nonlinear Compton Scattering in the Radiation-Dominated Regime

    NASA Astrophysics Data System (ADS)

    Li, Jian-Xing; Hatsagortsyan, Karen Z.; Galow, Benjamin J.; Keitel, Christoph H.

    2015-11-01

    The feasibility of the generation of bright ultrashort gamma-ray pulses is demonstrated in the interaction of a relativistic electron bunch with a counterpropagating tightly focused superstrong laser beam in the radiation-dominated regime. The Compton scattering spectra of gamma radiation are investigated using a semiclassical description for the electron dynamics in the laser field and a quantum electrodynamical description for the photon emission. We demonstrate the feasibility of ultrashort gamma-ray bursts of hundreds of attoseconds and of dozens of megaelectronvolt photon energies in the near-backwards direction of the initial electron motion. The tightly focused laser field structure and the radiation reaction are shown to be responsible for such short gamma-ray bursts, which are independent of the durations of the electron bunch and of the laser pulse. The results are measurable with the laser technology available in the near future.

  5. Virtual Compton Scattering at low energy and the generalized polarizabilities of the nucleon

    SciTech Connect

    Helene Fonvieille

    2003-05-01

    Virtual Compton Scattering (VCS) {gamma}*p {yields} {gamma}p at low CM energy gives access to the Generalized Polarizabilities of the nucleon. These observables generalize the concept of electromagnetic polarizabilities to the case of a virtual photon. Dedicated VCS experiments have been performed at MAMI, Jefferson Lab and MIT-Bates. The experimental status is reviewed, including analysis methods and physics results. The measurement of absolute (ep {yields} ep{gamma}) cross sections allows the extraction of the two unpolarized VCS structure functions P{sub LL}-P{sub TT}/{epsilon} and P{sub LT}, which are combinations of the Generalized Polarizabilities of the proton. Future prospects in the field of VCS at low energy are also presented.

  6. Rayleigh to Compton ratio scatter tomography applied to breast cancer diagnosis: A preliminary computational study

    NASA Astrophysics Data System (ADS)

    Antoniassi, M.; Conceição, A. L. C.; Poletti, M. E.

    2014-02-01

    In the present work, a tomographic technique based on Rayleigh to Compton scattering ratio (R/C) was studied using computational simulation in order to assess its application to breast cancer diagnosis. In this preliminary study, some parameters that affect the image quality were evaluated, such as: (i) energy beam, (ii) size and glandularity of the breast, and (iii) statistical count noise. The results showed that the R/C contrast increases with increasing photon energy and decreases with increasing glandularity of the sample. The statistical noise showed to be a significant parameter, although the quality of the obtained images was acceptable for a considerable range of noise level. The preliminary results suggest that the R/C tomographic technique has a potential of being applied as a complementary tool in the breast cancer diagnostic.

  7. Measurements of Compton Scattering on the Proton at 2 - 6 GeV

    SciTech Connect

    Danagoulian, Areg

    2006-05-01

    Similar to elastic electron scattering, Compton Scattering on the proton at high momentum transfers(and high p⊥) can be an effective method to study its short-distance structure. An experiment has been carried out to measure the cross sections for Real Compton Scattering (RCS) on the proton for 2.3-5.7 GeV electron beam energies and a wide distribution of large scattering angles. The 25 kinematic settings sampled a domain of s = 5-11(GeV/c)2,-t = -7(GeV/c)2 and -u = 0.5-6.5(GeV/c)2. In addition, a measurement of longitudinal and transverse polarization transfer asymmetries was made at a 3.48 GeV beam energy and a scattering angle of θcm = 120o. These measurements were performed to test the existing theoretical mechanisms for this process as well as to determine RCS form factors. At the heart of the scientific motivation is the desire to understand the manner in which a nucleon interacts with external excitations at the above listed energies, by comparing and contrasting the two existing models – Leading Twist Mechanism and Soft Overlap “Handbag” Mechanism – and identify the dominant mechanism. Furthermore, the Handbag Mechanism allows one to calculate reaction observables in the framework of Generalized Parton Distributions (GPD), which have the function of bridging the wide gap between the exclusive(form factors) and inclusive(parton distribution functions) description of the proton. The experiment was conducted in Hall A of Thomas Jefferson National Accelerator Facility(Jefferson Lab). It used a polarized and unpolarized electron beam, a 6% copper radiator with the thickness of 6.1% radiation lengths (to produce a bremsstrahlung photon beam), the Hall A liquid hydrogen target, a high resolution spectrometer with a focal plane polarimeter, and a photon hodoscope calorimeter. Results of the differential cross sections are presented, and discussed in the general context of the scientific motivation.

  8. Model-Based Detection of Radioactive Contraband for Harbor Defense Incorporating Compton Scattering Physics

    SciTech Connect

    Candy, J V; Chambers, D H; Breitfeller, E F; Guidry, B L; Verbeke, J M; Axelrod, M A; Sale, K E; Meyer, A M

    2010-03-02

    The detection of radioactive contraband is a critical problem is maintaining national security for any country. Photon emissions from threat materials challenge both detection and measurement technologies especially when concealed by various types of shielding complicating the transport physics significantly. This problem becomes especially important when ships are intercepted by U.S. Coast Guard harbor patrols searching for contraband. The development of a sequential model-based processor that captures both the underlying transport physics of gamma-ray emissions including Compton scattering and the measurement of photon energies offers a physics-based approach to attack this challenging problem. The inclusion of a basic radionuclide representation of absorbed/scattered photons at a given energy along with interarrival times is used to extract the physics information available from the noisy measurements portable radiation detection systems used to interdict contraband. It is shown that this physics representation can incorporated scattering physics leading to an 'extended' model-based structure that can be used to develop an effective sequential detection technique. The resulting model-based processor is shown to perform quite well based on data obtained from a controlled experiment.

  9. Optimization of a compton scatterer for hard x-ray weapons effects simulation in an ICF facility. Master's thesis

    SciTech Connect

    Tinsley, R.L.

    1990-03-01

    This thesis examined the optimization of a Compton scatterer for use in simulating hard X-ray effects in the proposed Laboratory Microfusion Facility (LMF). The LMF will produce inertial confinement fusion of deuterium-tritium pellets. The Compton scatterer is designed to reflect the X rays produced from the fusion toward a target. The scatterer should produce the maximum X-ray dose at the target while minimizing the neutron dose and gamma production. The scatterer must also control the dose rate by spreading the X-ray pulse to achieve a full width at half maximum on the order of 10s of ns. The current geometry includes a spherical Compton scatterer made of lithium hydride enriched to 95.6% Lithium 6. This work explored various parabolic scatterers using Monte Carlo transport calculations performed on the MCNP computer program from Los Alamos National Lab. The parabolic shape was optimized to increased the X-ray dose at a silicone target by a factor of 7. The geometry also decreased the neutron and gamma doses to less than 1% of the X-ray dose while achieving an 80% uniformity of dose across a 1-meter-radius silicon disk.

  10. The hydrogen anomaly in neutron Compton scattering: new experiments and a quantitative theoretical explanation

    NASA Astrophysics Data System (ADS)

    Karlsson, E. B.; Hartmann, O.; Chatzidimitriou-Dreismann, C. A.; Abdul-Redah, T.

    2016-08-01

    No consensus has been reached so far about the hydrogen anomaly problem in Compton scattering of neutrons, although strongly reduced H cross-sections were first reported almost 20 years ago. Over the years, this phenomenon has been observed in many different hydrogen-containing materials. Here, we use yttrium hydrides as test objects, YH2, YH3, YD2 and YD3, Y(H x D1‑x )2 and Y(H x D1‑x )3, for which we observe H anomalies increasing with transferred momentum q. We also observe reduced deuteron cross-sections in YD2 and YD3 and have followed those up to scattering angles of 140° corresponding to high momentum transfers. In addition to data taken using the standard Au-197 foils for neutron energy selection, the present work includes experiments with Rh-103 foils and comparisons were also made with data from different detector setups. The H and D anomalies are discussed in terms of the different models proposed for their interpretation. The ‘electron loss model’ (which assumes energy transfer to excited electrons) is contradicted by the present data, but it is shown here that exchange effects in scattering from two or more protons (or deuterons) in the presence of large zero-point vibrations, can explain quantitatively the reduction of the cross-sections as well as their q-dependence. Decoherence processes also play an essential role. In a scattering time representation, shake-up processes can be followed on the attosecond scale. The theory also shows that large anomalies can appear only when the neutron coherence lengths (determined by energy selection and detector geometry) are about the same size as the distance between the scatterers.

  11. The study of the magnetization process of fe film by magnetic Compton scattering and Mössbauer spectroscopy

    NASA Astrophysics Data System (ADS)

    Agui, Akane; Masuda, Ryo; Kobayashi, Yasuhiro; Kato, Tadashi; Emoto, Shun; Suzuki, Kosuke; Sakurai, Hiroshi

    2016-06-01

    The magnetization process of Fe (110) film was investigated using the field dependence of magnetic Compton scattering and Mössbauer spectroscopy. The spin and orbital magnetic moment specific magnetization versus magnetizing field curves were obtained from the magnetic Compton profiles, and the angles between the magnetizing field and the magnetic moment, θ, were obtained from the Mössbauer spectra. It was found that the magnetizing field dependence of the ratio between orbital moment and spin moment was related to θ. We indicate that the magnetic field dependence of the orbital magnetic moment plays a role in the magnetization process.

  12. Harmonic radiation of a relativistic nonlinear inverse Compton scattering using two laser wavelengths

    NASA Astrophysics Data System (ADS)

    Sakai, Y.; Williams, O.; Andonian, G.; Fukasawa, A.; Hemsing, E.; Marinelli, A.; Barber, S.; O'Shea, F. H.; Rosenzweig, J. B.

    2011-12-01

    The use of two different wavelength lasers in the nonlinear regime of the inverse Compton scattering interaction is proposed in order to provide a new strategy for controlling scattered photon energy distributions in the x-ray to γ-ray spectral region. In this nonlinear interaction, the component of the relativistic electron’s trajectory driven by a longer-wavelength laser with the normalized vector potential aL˜1 is a large oscillatory figure-8; in the proposed scenario a rapid small-amplitude oscillation induced by a shorter-wavelength laser is superimposed upon this figure-8. Thus, the electron’s momentum is mainly supplied from longer-wavelength laser, while the high-frequency part of the acceleration is given by shorter-wavelength laser. In this way, the harmonics radiated at high frequency from the oscillating electron can be strongly modified by the nonlinear motion initiated by the low frequency, large aL laser resulting in the generation of the harmonics with the photon energy of 4γ2h̵(ωL,short+nωL,long). In this paper, the electron’s kinetics in the two-wavelength laser field and the concomitant emitted radiation spectrum are examined, with numerical illustrations based on a classical Lienard-Wiechert potential formalism provided.

  13. Proton vibrational dynamics in lithium imide investigated through incoherent inelastic and Compton neutron scattering.

    PubMed

    Pietropaolo, A; Colognesi, D; Catti, M; Nale, A-C; Adams, M A; Ramirez-Cuesta, A J; Mayers, J

    2012-11-28

    In the present study we report neutron spectroscopic measurements on polycrystalline lithium imide, namely, incoherent inelastic neutron scattering at 20 K, and neutron Compton scattering from 10 K up to room temperature. From the former technique the H-projected density of phonon states up to 100 meV is derived, while the latter works out the spherically averaged single-particle (i.e., H, Li, and N) momentum distributions and, from this, the mean kinetic energies. Only for H at the lowest investigated temperature, non-gaussian components of its momentum distribution are detected. However, these components do not seem directly connected to the system anharmonicity, being fully compatible with the simple N-H bond anisotropy. Neutron data are also complemented by ab initio lattice dynamics simulations, both harmonic and, at room temperature, carried out in the framework of the so-called "quantum colored noise thermostat" method. The single-particle mean kinetic energies in lithium imide as a function of temperature show a quite peculiar behavior at the moment not reproduced by ab initio lattice dynamics methods, at least as far as H and Li are concerned. As matter of fact, neither their low temperature values nor their temperature trends can be precisely explained in terms of standard phonon calculations. PMID:23206005

  14. Lorentz Invariance Violation: Modification of the Compton Scattering and the GZK Cutoff and Other Effects

    NASA Astrophysics Data System (ADS)

    Sidharth, B. G.; Das, Abhishek; Roy, Arka Dev

    2016-05-01

    This paper deals with the violation of Lorentz symmetry. The approach is based on Compton scattering which becomes modified due to a modified dispersion relation arising from a minimum spacetime cut off as in modern Quantum Gravity approaches. With this amendment, we find that two high-energy rays of different energies develop a time-lag. This time separation becomes prominent when the energies of the considered photons is ≥ 1 GeV. Extending our approach to gamma rays of cosmic origin we predict that they undergo innumerable such scattering processes before reaching us. Therefore, it accounts for the time-lag phenomena of gamma ray bursts ( GRB)'s which have been claimed to be observed. Also, we find that resorting to the modified Snyder-Sidharth Hamiltonian it is possible to extend the GZK cut off beyond its normal limit, 1020 eV. Some observations of ultra high energy cosmic rays support this. This extends the limits of special theory of relativity.

  15. Elastic Compton Scattering from the Deuteron Near 100 MeV

    NASA Astrophysics Data System (ADS)

    Kovash, Michael; Shoniyozov, Khayrullo; Compton@MAX-lab Collaboration

    2015-10-01

    Differential cross sections for elastic Compton scattering from targets of carbon and deuterium have been measured from 86 to 113 MeV using a tagged bremsstrahlung beam at the MAX 1 electron storage ring in Lund, Sweden. Photon spectra were collected in 2009 and 2010 at scattering angles of 60, 120 and 150 degrees using three very large, high efficiency NaI spectrometers, each with a FWHM resolution of approximately 2 MeV. The deuterium target consisted of a cryogenic liquid cell of 17 cm length. Improvements made to the running conditions of previous MAX-lab data sets include the use of multi-hit time digitizers, and reduced instantaneous counting rates in both the tagging and the NaI detectors. GEANT4 simulations have been used to determine the photon detector response and efficiency, as well as the photon losses in the targets. The overall accuracy of this procedure is verified by comparing the current carbon results with previous data. The new deuterium cross sections will be presented and compared with the earlier results from this collaboration. The combined data set will be compared with recent Chiral Effective Field Theory calculations to determine the values of the neutron polarizabilities, αn and βn.

  16. Constraint on pulsar wind properties from induced Compton scattering off radio pulses

    NASA Astrophysics Data System (ADS)

    Tanaka, Shuta J.; Takahara, Fumio

    2013-12-01

    Pulsar winds have longstanding problems in energy conversion and pair cascade processes, which determine the magnetization σ , the pair multiplicity kappa , and the bulk Lorentz factor γ of the wind. We study induced Compton scattering by a relativistically moving cold plasma to constrain the wind properties by imposing that radio pulses from the pulsar itself are not scattered by the wind, as was first studied by Wilson and Rees [D. B. Wilson and M. J. Rees, Mon. Not. R. Astron. Soc., 185, 297 (1978)]. We find that relativistic effects cause a significant increase or decrease of the scattering coefficient depending on scattering geometry. Applying this to the Crab, we consider the uncertainties of the inclination angle of the wind velocity with respect to the radio beam θ _{pl} and the emission region size re, which determines the opening angle of the radio beam. We obtain the lower limit γ gtrsim 10^{1.7} r^{1/2}_{{e},3}θ ^{-1}_pl(1+σ)^{-1/4} (re = 10^3r_{{ e},3} cm) at the light cylinder r_{LC} for an inclined wind θ _{pl} >10^{-2.7}. For an aligned wind θ _{pl} < 10^{-2.7}, we require γ >10^{2.7} at r_{LC} and an additional constraint γ >10^{3.4}r^{1/5}_{{e},3}(1+σ)^{-1/10} at the characteristic scattering radius r_c=10^{9.6}r^{2/5}_{{e},3} cm, within which the `lack of time' effect prevents scattering. Considering the lower limit kappa gtrsim 10^{6.6} suggested by recent studies of the Crab Nebula, for re=10^3 cm, we obtain the most optimistic constraint 10^{1.7}lesssim γ lesssim 10^{3.9} and 10^{6.6}lesssim kappa lesssim 10^{8.8}, which are independent of r when θ _{pl}˜ 1 and 1+σ ˜ 1 at r_LC.

  17. Analysis of the data from Compton X-ray polarimeters which measure the azimuthal and polar scattering angles

    NASA Astrophysics Data System (ADS)

    Krawczynski, H.

    2011-05-01

    X-ray polarimetry has the potential to make key-contributions to our understanding of galactic compact objects like binary black hole systems and neutron stars, and extragalactic objects like active galactic nuclei, blazars, and Gamma-Ray Bursts. Furthermore, several particle astrophysics topics can be addressed including uniquely sensitive tests of Lorentz invariance. In the energy range from 10 keV to several MeV, Compton polarimeters achieve the best performance. In this paper we evaluate the benefit that comes from using the azimuthal and polar angles of the Compton scattered photons in the analysis, rather than using the azimuthal scattering angles alone. We study the case of an ideal Compton polarimeter and show that a Maximum Likelihood analysis which uses the two scattering angles lowers the Minimum Detectable Polarization (MDP) by ≈20% compared to a standard analysis based on the azimuthal scattering angles alone. The accuracies with which the polarization fraction and the polarization direction can be measured improve by a similar amount. We conclude by discussing potential applications of Maximum Likelihood analysis methods for various polarimeter experiments.

  18. X-band RF gun and linac for medical Compton scattering X-ray source

    NASA Astrophysics Data System (ADS)

    Dobashi, Katsuhito; Uesaka, Mitsuru; Fukasawa, Atsushi; Sakamoto, Fumito; Ebina, Futaro; Ogino, Haruyuki; Urakawa, Junji; Higo, Toshiyasu; Akemoto, Mitsuo; Hayano, Hitoshi; Nakagawa, Keiichi

    2004-12-01

    Compton scattering hard X-ray source for 10-80 keV are under construction using the X-band (11.424 GHz) electron linear accelerator and YAG laser at Nuclear Engineering Research laboratory, University of Tokyo. This work is a part of the national project on the development of advanced compact medical accelerators in Japan. National Institute for Radiological Science is the host institute and U.Tokyo and KEK are working for the X-ray source. Main advantage is to produce tunable monochromatic hard (10-80 keV) X-rays with the intensities of 108-1010 photons/s (at several stages) and the table-top size. Second important aspect is to reduce noise radiation at a beam dump by adopting the deceleration of electrons after the Compton scattering. This realizes one beamline of a 3rd generation SR source at small facilities without heavy shielding. The final goal is that the linac and laser are installed on the moving gantry. We have designed the X-band (11.424 GHz) traveling-wave-type linac for the purpose. Numerical consideration by CAIN code and luminosity calculation are performed to estimate the X-ray yield. X-band thermionic-cathode RF-gun and RDS(Round Detuned Structure)-type X-band accelerating structure are applied to generate 50 MeV electron beam with 20 pC microbunches (104) for 1 microsecond RF macro-pulse. The X-ray yield by the electron beam and Q-switch Nd:YAG laser of 2 J/10 ns is 107 photons/RF-pulse (108 photons/sec at 10 pps). We design to adopt a technique of laser circulation to increase the X-ray yield up to 109 photons/pulse (1010 photons/s). 50 MW X-band klystron and compact modulator have been constructed and now under tuning. The construction of the whole system has started. X-ray generation and medical application will be performed in the early next year.

  19. Constraints on the H˜ generalized parton distribution from deep virtual Compton scattering measured at HERMES

    NASA Astrophysics Data System (ADS)

    Guidal, M.

    2010-09-01

    We have analyzed the longitudinally polarized proton target asymmetry data of the Deep Virtual Compton process recently published by the HERMES Collaboration in terms of Generalized Parton Distributions. We have fitted these new data in a largely model-independent fashion and the procedure results in numerical constraints on the accent="true">H˜Im Compton Form Factor. We present its t- and ξ-dependencies. We also find improvement on the determination of two other Compton Form Factors, HRe and HIm.

  20. Electronic structure of CdMoO4 using Compton scattering technique

    NASA Astrophysics Data System (ADS)

    Sharma, Khushboo; Sahariya, Jagrati; Ahuja, B. L.

    2014-04-01

    The first ever Compton profile of polycrystalline CdMoO4 has been measured using 137Cs spectrometer. The results are compared with theoretical Compton profiles deduced from free atom and linear combination of atomic orbitals (LCAO) methods. We have also computed the energy bands using density functional theory (DFT) within LCAO. The computed bands confirm the semiconducting behaviour of this compound. It is seen that the DFT theoretical profile (with local density approximation) gives a better agreement with the experimental Compton data than free atom Compton profile.

  1. Simplified Formulae System for Resonant Inverse Compton Scattering of a Fast Electron in an Intense Magnetic Field

    NASA Technical Reports Server (NTRS)

    You, J. H.; Chen, W. P.; Zhang, S. N.; Chen, L.; Liu, D.; Chou, C. K.

    2003-01-01

    We present simple analytical formulae for the emission spectrum and total power of a special kind of resonant inverse Compton scattering (RICS) of a relativistic electron in an intense magnetic field. In contrast with the available formulae system, we obtain a markedly simplified one based on the semiclassical quantum theory, which is more understandable for people who are unfamiliar with quantum electrodynamics. We show that the RICS process, under an appropriate 'accommodation condition' derived in this paper, is predominantly much more efficient than the coexistent ordinary inverse Compton scattering, and produces highly beamed high-frequency radiation with moderately good monochromaticity. Our formulae are simple to use - thus offering a lucid physical intuition for the theory - and may find wide applications in hard X-ray and gamma-ray astrophysics.

  2. Corrections for the effects of accidental coincidences, Compton scatter, and object size in positron emission mammography (PEM) imaging

    SciTech Connect

    Raymond Raylman; Stanislaw Majewski; Randolph Wojcik; Andrew Weisenberger; Brian Kross; Vladimir Popov

    2001-06-01

    Positron emission mammography (PEM) has begun to show promise as an effective method for the detection of breast lesions. Due to its utilization of tumor-avid radiopharmaceuticals labeled with positron-emitting radionuclides, this technique may be especially useful in imaging of women with radiodense or fibrocystic breasts. While the use of these radiotracers affords PEM unique capabilities, it also introduces some limitations. Specifically, acceptance of accidental and Compton-scattered coincidence events can decrease lesion detectability. The authors studied the effect of accidental coincidence events on PEM images produced by the presence of 18F-Fluorodeoxyglucose in the organs of a subject using an anthropomorphic phantom. A delayed-coincidence technique was tested as a method for correcting PEM images for the occurrence of accidental events. Also, a Compton scatter correction algorithm designed specifically for PEM was developed and tested using a compressed breast phantom.

  3. Visualizing the mixed bonding properties of liquid boron with high-resolution x-ray Compton scattering.

    PubMed

    Okada, J T; Sit, P H-L; Watanabe, Y; Barbiellini, B; Ishikawa, T; Wang, Y J; Itou, M; Sakurai, Y; Bansil, A; Ishikawa, R; Hamaishi, M; Paradis, P-F; Kimura, K; Ishikawa, T; Nanao, S

    2015-05-01

    Bonding characteristics of liquid boron at 2500 K are studied by using high-resolution Compton scattering. An excellent agreement is found between the measurements and the corresponding Car-Parrinello molecular dynamics simulations. Covalent bond pairs are clearly shown to dominate in liquid boron along with the coexistence of diffuse pairs. Our study reveals the complex bonding pattern of liquid boron and gives insight into the unusual properties of this high-temperature liquid. PMID:25978262

  4. Constraints on the virtual Compton scattering on the nucleon in a new dispersive formalism

    NASA Astrophysics Data System (ADS)

    Caprini, Irinel

    2016-04-01

    The dispersive representation of the virtual Compton forward scattering amplitude has been recently reexamined in connection with the evaluation of the Cottingham formula for the proton-neutron electromagnetic mass difference and the proton radius puzzle. The most difficult part of the analysis is related to one of the invariant amplitudes, denoted as T1(ν ,Q2), which requires a subtraction in the standard dispersion relation with respect to the energy ν at fixed photon momentum squared q2=-Q2. We propose an alternative dispersive framework, which implements analyticity and unitarity by combining the Cauchy integral relation at low and moderate energies with the modulus representation of the amplitude at high energies. Using techniques of functional analysis, we derive a necessary and sufficient condition for the consistency with analyticity of the subtraction function S1(Q2)=T1(0 ,Q2) , the cross sections measured at low and moderate energies and the Regge model assumed to be valid at high energies. From this condition we obtain model-independent constraints on the subtraction function, confronting them with the available information on nucleon magnetic polarizabilities and results reported recently in the literature. The formalism can be used also for testing the existence of a fixed pole at J =0 in the angular momentum plane, but more accurate data are necessary for a definite answer.

  5. A New 3He-Target Design for Compton Scattering Experiment

    NASA Astrophysics Data System (ADS)

    Mahalchick, S.; Gao, H.; Laskaris, G.; Weir, W.; Ye, Q.; Ye, Q. J.

    2011-10-01

    The neutron spin polarizabilities describe the stiffness of the neutron spin to external electric and magnetic fields. A double-polarized elastic Compton Scattering experiment will try to determine the neutron spin polarizabilities using a new polarized 3He target and the circularly polarized γ-beam of HI γS facility at the Duke Free Electron Laser Laboratory (DFELL). To polarize the 3He target, a newly constructed solenoid is being used which can provide a very uniform magnetic field around the target area and allows to place High Intensity Gamma Source NaI Detector Arrays (HINDA) closer to the target. The ideal target polarization is 40-60% and will be measured using the nuclear magnetic resonance (NMR) and electron paramagnetic resonance (EPR) techniques. A prototype of the polarized 3He target is being constructed in the Medium Energy Physics Group laboratories at Duke and is currently being tested. The experiment is expected to take place in 2013 after the DFELL upgrade. I will be presenting details of the construction process, including design specifications and data from the magnetic field mapping, as well as preliminary target polarization results. This work is supported by the US Department of Energy, under contract number DE-FG02-03ER41231, and by the National Science Foundation, grant number NSF-PHY-08-51813.

  6. CONSTRAINT ON THE PARAMETERS OF THE INVERSE COMPTON SCATTERING MODEL FOR RADIO PULSARS

    SciTech Connect

    Lv, M.; Wang, H. G.; Lee, K. J.; Qiao, G. J.; Xu, R. X.

    2011-11-01

    The inverse Compton scattering (ICS) model can explain various pulse profile shapes and the diversity of the pulse profile evolution based on the mechanism where the radio emission is generated through ICS between secondary relativistic particles and radio waves from polar gap avalanches. In this paper, we study the parameter space of the ICS model for 15 pulsars that share the common pulse profile evolution phenomenon, where the pulse profiles are narrower at higher observing frequencies. Two key parameters, the initial Lorentz factor and the energy loss factor of secondary particles, are constrained using the least-squares fitting method, where we fit the theoretical curve of the 'beam-frequency mapping' of the ICS model to the observed pulse widths at multiple frequencies. The uncertainty of the inclination and viewing angles are taken into account in the fitting process. It is found that the initial Lorentz factor is larger than 4000, and the energy loss factor is between 20 and 560. The Lorentz factor is consistent with the prediction of the inner vacuum gap model. Such high-energy loss factors suggest significant energy loss for secondary particles at altitudes of a few tens to hundreds of kilometers.

  7. Demonstration of energy-coded Compton scatter tomography with fan beams for one-sided inspection

    NASA Astrophysics Data System (ADS)

    Evans, Brian L.; Martin, Jeffrey B.; Burggraf, Larry W.; Roggemann, M. C.; Hangartner, T. N.

    2002-03-01

    An instrument is demonstrated whereby radiographic images of a sample's electron density are compiled from the information encoded in the energy spectra of gamma rays backscattered from one side of the sample. It is assumed that access is restricted to only one surface of the object under inspection. Use of energy coding allows imaging in a fan beam rather than independent interrogation of individual volume elements. The Multiplexed Compton Scatter Tomograph instrument consists of an array of high-energy-resolution detectors and fan beam collimators. Instrument signals are converted to electron density images using a penalized weighted least squares image reconstruction algorithm coupled with a deterministic system model that includes effects of Doppler broadening. The proof-of-principle instrument is demonstrated on aluminum samples. In an 8 mm thick sample with a 4 mm void in its center, contrast recovery of 90% is achieved. In a 10 mm thick sample with a 3 mm void at the back about 85% of the contrast is recovered.

  8. Inverse Compton Scattering on Solar Photons, Heliospheric Modulation, and Neutrino Astrophysics

    SciTech Connect

    Moskalenko, Igor V.; Porter, Troy A.; Digel, Seth W.; /SLAC

    2006-08-01

    We study the inverse Compton scattering of solar photons by Galactic cosmic-ray electrons. We show that the {gamma}-ray emission from this process is significant with the maximum flux in the direction of the Sun; the angular distribution of the emission is broad. This previously neglected foreground should be taken into account in studies of the diffuse Galactic and extragalactic {gamma}-ray emission. Furthermore, observations by GLAST can be used to monitor the heliosphere and determine the electron spectrum as a function of position from distances as large as Saturn's orbit down to close proximity of the Sun, thus enabling studies of solar modulation in the most extreme case. This paves the way for the determination of other Galactic cosmic-ray species, primarily protons, near the solar surface leading to accurate predictions of {gamma}-rays from pp-interactions in the solar atmosphere. These albedo {gamma}-rays will be observable by GLAST, allowing the study of deep atmospheric layers, magnetic field(s), and cosmic-ray cascade development. The latter is necessary to calculate the neutrino flux from pp-interactions at higher energies (>1 TeV). The corresponding neutrino flux from the Sun can be used as a ''standard candle'' for upcoming km{sup 3} neutrino detectors, such as IceCube. Since the solar core is opaque for very high-energy neutrinos, it may be possible to directly study the mass distribution of the Sun.

  9. Polarization of x-gamma radiation produced by a Thomson and Compton inverse scattering

    NASA Astrophysics Data System (ADS)

    Petrillo, V.; Bacci, A.; Curatolo, C.; Drebot, I.; Giribono, A.; Maroli, C.; Rossi, A. R.; Serafini, L.; Tomassini, P.; Vaccarezza, C.; Variola, A.

    2015-11-01

    A systematic study of the polarization of x-gamma rays produced in Thomson and Compton scattering is presented, in both classical and quantum schemes. Numerical results and analytical considerations let us to establish the polarization level as a function of acceptance, bandwidth and energy. Few sources have been considered: the SPARC_LAB Thomson device, as an example of a x-ray Thomson source, ELI-NP, operating in the gamma range. Then, the typical parameters of a beam produced by a plasma accelerator has been analyzed. In the first case, with bandwidths up to 10%, a contained reduction (<10 % ) in the average polarization occurs. In the last case, for the nominal ELI-NP relative bandwidth of 5 ×1 0-3 , the polarization is always close to 1. For applications requiring larger bandwidth, however, a degradation of the polarization up to 30% must be taken into account. In addition, an all optical gamma source based on a plasma accelerated electron beam cannot guarantee narrow bandwidth and high polarization operational conditions required in nuclear photonics experiments.

  10. X-ray generation by inverse Compton scattering at the superconducting RF test facility

    NASA Astrophysics Data System (ADS)

    Shimizu, Hirotaka; Akemoto, Mitsuo; Arai, Yasuo; Araki, Sakae; Aryshev, Alexander; Fukuda, Masafumi; Fukuda, Shigeki; Haba, Junji; Hara, Kazufumi; Hayano, Hitoshi; Higashi, Yasuo; Honda, Yosuke; Honma, Teruya; Kako, Eiji; Kojima, Yuji; Kondo, Yoshinari; Lekomtsev, Konstantin; Matsumoto, Toshihiro; Michizono, Shinichiro; Miyoshi, Toshinobu; Nakai, Hirotaka; Nakajima, Hiromitsu; Nakanishi, Kota; Noguchi, Shuichi; Okugi, Toshiyuki; Sato, Masato; Shevelev, Mikhail; Shishido, Toshio; Takenaka, Tateru; Tsuchiya, Kiyosumi; Urakawa, Junji; Watanabe, Ken; Yamaguchi, Seiya; Yamamoto, Akira; Yamamoto, Yasuchika; Sakaue, Kazuyuki; Hosoda, Seiichi; Iijima, Hokuto; Kuriki, Masao; Tanaka, Ryuta; Kuramoto, Ayaka; Omet, Mathieu; Takeda, Ayaki

    2015-02-01

    Quasi-monochromatic X-rays with high brightness have a broad range of applications in fields such as life sciences, bio-, medical applications, and microlithography. One method for generating such X-rays is via inverse Compton scattering (ICS). X-ray generation experiments using ICS were carried out at the superconducting RF test facility (STF) accelerator at KEK. A new beam line, newly developed four-mirror optical cavity system, and new X-ray detector system were prepared for experiments downstream section of the STF electron accelerator. Amplified pulsed photons were accumulated into a four-mirror optical cavity and collided with an incoming 40 MeV electron beam. The generated X-rays were detected using a microchannel plate (MCP) detector for X-ray yield measurements and a new silicon-on-insulator (SOI) detector system for energy measurements. The detected X-ray yield by the MCP detector was 1756.8±272.2 photons/(244 electron bunches). To extrapolate this result to 1 ms train length under 5 Hz operations, 4.60×105 photons/1%-bandwidth were obtained. The peak X-ray energy, which was confirmed by the SOI detector, was 29 keV, and this is consistent with ICS X-rays.

  11. A New High-Accuracy Analysis of Compton Scattering in Chiral EFT: Neutron Polarisabilities

    NASA Astrophysics Data System (ADS)

    Griesshammer, Harald W.; McGovern, Judith A.; Phillips, Daniel R.

    2015-04-01

    Low-energy Compton scattering tests the symmetries and interaction strengths of a target's internal degrees of freedom in the electric and magnetic fields of a real, external photon. In the single-nucleon sector, information is often compressed into the static scalar dipole polarisabilities which are experimentally not directly accessible but encode information on the pion cloud and the Δ(1232) excitation. The interaction of the photon with the charged pion-exchange also provides a conceptually clean probe of few-nucleon binding. After demonstrating the statistical consistency of the world's γd dataset including the new data from the MAX-IV collaboration described in the preceding talk, we present a new extraction of the neutron polarisabilities in Chiral Effective Field Theory: αn = [ 11 . 55 +/- 1 . 25(stat) +/- 0 . 2(BSR) +/- 0 . 8(th) ] and βn = [ 3 . 65 -/+ 1 . 25(stat) +/- 0 . 2(BSR) -/+ 0 . 8(th) ] , in 10-4 fm3, with χ2 = 45 . 2 for 44 degrees of freedom. The new data reduced the statistical uncertainties by 30%. We discuss data accuracy and consistency, the role of the Δ(1232) , and an estimate of residual theoretical uncertainties. Within statistical and systematic errors, proton and neutron polarisabilities remain identical. Supported in part by UK STFC and US DOE.

  12. Second order formalism for spin (1/2) fermions and Compton scattering

    SciTech Connect

    Delgado-Acosta, E. G.; Napsuciale, Mauro; Rodriguez, Simon

    2011-04-01

    We develop a second order formalism for massive spin 1/2 fermions based on the projection over Poincare invariant subspaces in the ((1/2),0)+(0,(1/2)) representation of the homogeneous Lorentz group. Using the U(1){sub em} gauge principle we obtain a second order description for the electromagnetic interactions of a spin 1/2 fermion with two free parameters, the gyromagnetic factor g and a parameter {xi} related to odd-parity Lorentz structures. We calculate Compton scattering in this formalism. In the particular case g=2, {xi}=0, and for states with well-defined parity, we recover Dirac results. In general, we find the correct classical limit and a finite value r{sub c}{sup 2} for the forward differential cross section, independent of the photon energy and of the value of the parameters g and {xi}. The differential cross section vanishes at high energies for all g, {xi} except in the forward direction. The total cross section at high energies vanishes only for g=2, {xi}=0. We argue that this formalism is more convenient than Dirac theory in the description of low energy electromagnetic properties of baryons and illustrate the point with the proton case.

  13. Fermi-Compton scattering due to magnetopause surface fluctuations in Jupiter's magnetospheric cavity

    NASA Technical Reports Server (NTRS)

    Barbosa, D. D.

    1981-01-01

    The effects of boundary surface fluctuations on a spectrum of electromagnetic radiation trapped in a high Q (quality) cavity are considered. Undulating walls introduce small frequency shifts at reflection to the radiation, and it is argued that the process is entirely analogous to both Fermi (particle) acceleration and inverse Compton scattering. A Fokker-Planck formalism is pursued; it yields a diffusion equation in frequency for which the Green's function and steady-state solutions are found. Applying this analysis to the Jovian continuum radiation discovered by Voyager spacecraft, it is suggested that characteristic diffusion times are greater than 1 year, and that in order to account for the steep frequency spectra observed, an unidentified loss mechanism must operate in the cavity with a decay time constant approximately equal to the characteristic diffusion time divided by 28. A radiator-reactor model of the cavity is investigated to provide an estimate for the intrinsic luminosity of the low frequency (approximately 100 Hz) continuum source whose power is approximately 7 x 10 to the 6th W.

  14. Design and Operation of a tunable MeV-level Compton-scattering-based (gamma-ray) source

    SciTech Connect

    Gibson, D J; Albert, F; Anderson, S G; Betts, S M; Messerly, M J; Phan, H H; Semenov, V A; Shverdin, M Y; Tremaine, A M; Hartemann, F V; Siders, C W; McNabb, D P; Barty, C P

    2009-07-07

    A mono-energetic gamma-ray (MEGa-ray) source based on Compton-scattering, targeting nuclear physics applications such as nuclear resonance fluorescence, has been constructed and commissioned at Lawrence Livermore National Laboratory. In this paper, the overall architecture of the system, as well as some of the critical design decisions made in the development of the source, are discussed. The performances of the two laser systems (one for electron production, one for scattering), the electron photoinjector, and the linear accelerator are also detailed, and initial {gamma}-ray results are presented.

  15. Verification of Compton scattering spectrum of a 662keV photon beam scattered on a cylindrical steel target using MCNP5 code.

    PubMed

    Thanh, Tran Thien; Nguyen, Vo Hoang; Chuong, Huynh Dinh; Tran, Le Bao; Tam, Hoang Duc; Binh, Nguyen Thi; Tao, Chau Van

    2015-11-01

    This article focuses on the possible application of a (137)Cs low-radioactive source (5mCi) and a NaI(Tl) detector for measuring the saturation thickness of solid cylindrical steel targets. In order to increase the reliability of the obtained experimental results and to verify the detector response function of Compton scattering spectrum, simulation using Monte Carlo N-particle (MCNP5) code is performed. The obtained results are in good agreement with the response functions of the simulation scattering and experimental scattering spectra. On the basis of such spectra, the saturation depth of a steel cylinder is determined by experiment and simulation at about 27mm using gamma energy of 662keV ((137)Cs) at a scattering angle of 120°. This study aims at measuring the diameter of solid cylindrical objects by gamma-scattering technique. PMID:26363240

  16. Beam Diagnostics of the Compton Scattering Chamber in Jefferson Lab's Hall C

    NASA Astrophysics Data System (ADS)

    Faulkner, Adam; I&C Group Collaboration

    2013-10-01

    Upcoming experimental runs in Hall C will utilize Compton scattering, involving the construction and installation of a rectangular beam enclosure. Conventional cylindrical stripline-style Beam Position Monitors (BPMs) are not appropriate due to their form factor; therefore to facilitate measurement of position, button-style BPMs are being considered due to the ease of placement within the new beam enclosure. Button BPM experience is limited at JLAB, so preliminary measurements are needed to characterize the field response, and guide the development of appropriate algorithms for the Analog to Digital receiver systems. -field mapping is performed using a Goubau Line (G-Line), which employs a surface wave to mimic the electron beam, helping to avoid problems associated with vacuum systems. Potential algorithms include simplistic 1/r modeling (-field mapping), look-up-tables, as well as a potential third order power series fit. In addition, the use of neural networks specifically the multi-layer Perceptron will be examined. The models, sensor field maps, and utility of the neural network will be presented. Next steps include: modification of the control algorithm, as well as to run an in-situ test of the four Button electrodes inside of a mock beam enclosure. The analysis of the field response using Matlab suggests the button BPMs are accurate to within 10 mm, and may be successful for beam diagnostics in Hall C. More testing is necessary to ascertain the limitations of the new electrodes. The National Science Foundation, Old Dominion University, The Department of Energy, and Jefferson Lab.

  17. Extracting the cation distributions in NiFe2-xAlxO4 solid solutions using magnetic Compton scattering.

    PubMed

    Kamali, S; Shih, K; Barbiellini, B; Wang, Y J; Kaprzyk, S; Itou, M; Bansil, A; Sakurai, Y

    2015-11-18

    We discuss the ground state electronic structure and magnetization properties of a series of NiFe2-x Al x O4 solid solutions (x  =  0.0, 0.4, 0.8, 1.2, 1.6, and 2.0) using magnetic Compton scattering measurements, together with parallel first-principles computations. In this way, we systematically extract the complicated cation distributions in this ferrite system as a function of x. The relationship between the electronic ground state, magnetism, and cation distributions is explained in terms of a model, validated by our first-principles computations, wherein the magnetic properties of the three cation distributions are assumed to be different. A good accord is found between the computed and measured magnetic Compton profiles. PMID:26471985

  18. Non-Destructive Measurement of in-operando Lithium Concentration in Batteries via X-Ray Compton Scattering

    NASA Astrophysics Data System (ADS)

    Hafiz, Hasnain; Suzuki, K.; Barbiellini, B.; Orikasa, Y.; Kaprzyk, S.; Itou, M.; Yamamoto, K.; Wang, Y. J.; Uchimoto, Y.; Bansil, A.; Sakurai, Y.; Sakurai, H.

    Non-destructive determination of lithium distribution in a working battery is key for addressing both efficiency and safety issues. Although various techniques have been developed to map the lithium distribution in electrodes, these methods are mostly applicable to test cells. Here we propose the use of high-energy x-ray Compton scattering spectroscopy to measure the local lithium concentration in closed electrochemical cells. A combination of experimental measurements and parallel first-principles computations is used to show that the shape parameter S of the Compton profile is linearly proportional to lithium concentration and thus provides a viable descriptor for this important quantity. The merits and applicability of our method are demonstrated with illustrative examples of Lix Mn2O4 cathodes and a working commercial lithium coin battery CR2032.

  19. Non-destructive measurement of in-operando lithium concentration in batteries via x-ray Compton scattering

    NASA Astrophysics Data System (ADS)

    Suzuki, K.; Barbiellini, B.; Orikasa, Y.; Kaprzyk, S.; Itou, M.; Yamamoto, K.; Wang, Yung Jui; Hafiz, H.; Uchimoto, Y.; Bansil, A.; Sakurai, Y.; Sakurai, H.

    2016-01-01

    Non-destructive determination of lithium distribution in a working battery is key for addressing both efficiency and safety issues. Although various techniques have been developed to map the lithium distribution in electrodes, these methods are mostly applicable to test cells. Here, we propose the use of high-energy x-ray Compton scattering spectroscopy to measure the local lithium concentration in closed electrochemical cells. A combination of experimental measurements and parallel first-principles computations is used to show that the shape parameter S of the Compton profile is linearly proportional to lithium concentration and thus provides a viable descriptor for this important quantity. The merits and applicability of our method are demonstrated with illustrative examples of LixMn2O4 cathodes and a working commercial lithium coin battery CR2032.

  20. Frequency scaling law for nonlinear Compton and Thomson scattering: Relevance of spin and polarization effects

    NASA Astrophysics Data System (ADS)

    Krajewska, K.; Kamiński, J. Z.

    2014-11-01

    The distributions of Compton and Thomson radiation for a shaped laser pulse colliding with a free electron are calculated in the framework of quantum and classical electrodynamics, respectively. We introduce a scaling law for the Compton and the Thomson frequency distributions which universally applies to long and short incident pulses. Thus, we extend the validity of frequency scaling postulated in previous studies comparing nonlinear Compton and Thomson processes. The scaling law introduced in this paper relates the Compton no-spin flipping process to the Thomson process over nearly the entire spectrum of emitted radiation, including its high-energy portion. By applying the frequency scaling, we identify that both spin and polarization effects are responsible for differences between classical and quantum results. The same frequency scaling applies to angular distributions and to temporal power distributions of emitted radiation, which we illustrate numerically.

  1. Compton tomography system

    DOEpatents

    Grubsky, Victor; Romanoov, Volodymyr; Shoemaker, Keith; Patton, Edward Matthew; Jannson, Tomasz

    2016-02-02

    A Compton tomography system comprises an x-ray source configured to produce a planar x-ray beam. The beam irradiates a slice of an object to be imaged, producing Compton-scattered x-rays. The Compton-scattered x-rays are imaged by an x-ray camera. Translation of the object with respect to the source and camera or vice versa allows three-dimensional object imaging.

  2. Virtual Compton scattering and neutral pion electroproduction in the resonance region up to the deep inelastic region at backward angles

    SciTech Connect

    Laveissiere, G.; Jaminion, S.; Salvo, R. Di; Berthot, J.; Bertin, P. Y.; Breton, V.; Fonvieille, H.; Grenier, P.; Ravel, O.; Roblin, Y.; Smirnov, G.; Jutier, C.; Hyde, C. E.; Todor, L.; Dodge, G. E.; McCormick, K.; Ulmer, P. E.

    2009-01-15

    We have made the first measurements of the virtual Compton scattering (VCS) process via the H(e, e{sup '}p){gamma} exclusive reaction in the nucleon resonance region, at backward angles. Results are presented for the W-dependence at fixed Q{sup 2}=1 GeV{sup 2} and for the Q{sup 2} dependence at fixed W near 1.5 GeV. The VCS data show resonant structures in the first and second resonance regions. The observed Q{sup 2} dependence is smooth. The measured ratio of H(e, e{sup '}p){gamma} to H(e, e{sup '}p){pi}{sup 0} cross sections emphasizes the different sensitivity of these two reactions to the various nucleon resonances. Finally, when compared to real Compton scattering (RCS) at high energy and large angles, our VCS data at the highest W (1.8-1.9 GeV) show a striking Q{sup 2} independence, which may suggest a transition to a perturbative scattering mechanism at the quark level.

  3. Virtual Compton scattering and neutral pion electroproduction in the resonance region up to the deep inelastic region at backward angles

    SciTech Connect

    Laveissiere, Geraud; Degrande, Natalie; Jaminion, Stephanie; Jutier, Christophe; Todor, Luminita; Di Salvo, Rachele; Van Hoorebeke, L.; Alexa, L.C.; Anderson, Brian; Aniol, Konrad; Arundell, Kathleen; Audit, Gerard; Auerbach, Leonard; Baker, F.; Baylac, Maud; Berthot, J.; Bertin, Pierre; Bertozzi, William; Bimbot, Louis; Boeglin, Werner; Brash, Edward; Breton, Vincent; Breuer, Herbert; Burtin, Etienne; Calarco, John; Cardman, Lawrence; Cavata, Christian; Chang, C.; Chang, C.C.; Chang, C.; Chang, C.C.; Chang, C.; Chang, C.C.; Chang, C.; Chang, C.C.; Chen, Jian-Ping; Chudakov, Eugene; Cisbani, Evaristo; Dale, Daniel; De Jager, Cornelis; De Leo, Raffaele; Deur, Alexandre; D'Hose, Nicole; Dodge, Gail; Domingo, John; Elouadrhiri, Latifa; Epstein, Martin; Ewell, Lars; Finn, John; Fissum, Kevin; Fonvieille, Helene; Fournier, Guy; Frois, Bernard; Frullani, Salvatore; Furget, Christophe; Gao, Haiyan; Gao, Juncai; Garibaldi, Franco; Gasparian, Ashot; Gilad, Shalev; Gilman, Ronald; Glamazdin, Oleksandr; Glashausser, Charles; Gomez, Javier; Gorbenko, Viktor; Grenier, Philippe; Guichon, Pierre; Hansen, Jens-Ole; Holmes, Richard; Holtrop, Maurik; Howell, Calvin; Huber, Garth; Hyde, Charles; Incerti, Sebastien; Iodice, Mauro; Jardillier, Johann; Jones, Mark; Kahl, William; Kamalov, Sabit; Kato, Seigo; Katramatou, A.T.; Kelly, James; Kerhoas, Sophie; Ketikyan, Armen; Khayat, Mohammad; Kino, Kouichi; Kox, Serge; Kramer, Laird; Kumar, Krishna; Kumbartzki, Gerfried; Kuss, Michael; Leone, Antonio; LeRose, John; Liang, Meihua; Lindgren, Richard; Liyanage, Nilanga; Lolos, George; Lourie, Robert; Madey, Richard; Maeda, Kazushige; Malov, Sergey; Manley, D.; Marchand, Claude; Marchand, Dominique; Margaziotis, Demetrius; Markowitz, Pete; Marroncle, Jacques; Martino, Jacques; McCormick, Kathy; McIntyre, Justin; Mehrabyan, Surik; Merchez, Fernand; Meziani, Zein-Eddine; Michaels, Robert; Miller, Gerald; Mougey, Jean; Nanda, Sirish; Neyret, Damien; Offermann, Edmond; Papandreou, Zisis; Perdrisat, Charles; Perrino, R.; Petratos, Gerassimos; Platchkov, Stephane; Pomatsalyuk, Roman; Prout, David; Punjabi, Vina; Pussieux, Thierry; Quemener, Gilles; Ransome, Ronald; Ravel, Oliver; Real, Jean-Sebastien; Renard, F.; Roblin, Yves; Rowntree, David; Rutledge, Gary; Rutt, Paul; Saha, Arunava; Saito, Teijiro; Sarty, Adam; Serdarevic, A.; Smith, T.; Smirnov, G.; Soldi, K.; Sorokin, Pavel; Souder, Paul; Suleiman, Riad; Templon, Jeffrey; Terasawa, Tatsuo; Tiator, Lothar; Tieulent, Raphael; Tomasi-Gustaffson, E.; Tsubota, Hiroaki; Ueno, Hiroaki; Ulmer, Paul; Urciuoli, Guido; Van De Vyver, R.; van der Meer, Rob; Vernin, Pascal; Vlahovic, B.; Voskanyan, Hakob; Voutier, Eric; Watson, J.W.; Weinstein, Lawrence; Wijesooriya, Krishni; Wilson, R.; Wojtsekhowski, Bogdan; Zainea, Dan; Zhang, Wei-Ming; Zhao, Jie; Zhou, Z.-L.

    2009-01-01

    We have made the first measurements of the virtual Compton scattering (VCS) process via the H(e,e'p)? exclusive reaction in the nucleon resonance region, at backward angles. Results are presented for the W-dependence at fixed Q2=1 GeV2, and for the Q2-dependence at fixed W near 1.5 GeV. The VCS data show resonant structures in the first and second resonance regions. The observed Q2-dependence is smooth. The measured ratio of H(e,e'p)? to H(e,e'p)?0 cross sections emphasizes the different sensitivity of these two reactions to the various nucleon resonances. Finally, when compared to Real Compton Scattering (RCS) at high energy and large angles, our VCS data at the highest W (1.8-1.9 GeV) show a striking Q2-independence, which may suggest a transition to a perturbative scattering mechanism at the quark level.

  4. A Monte Carlo study of high-energy photon transport in matter: application for multiple scattering investigation in Compton spectroscopy

    PubMed Central

    Brancewicz, Marek; Itou, Masayoshi; Sakurai, Yoshiharu

    2016-01-01

    The first results of multiple scattering simulations of polarized high-energy X-rays for Compton experiments using a new Monte Carlo program, MUSCAT, are presented. The program is developed to follow the restrictions of real experimental geometries. The new simulation algorithm uses not only well known photon splitting and interaction forcing methods but it is also upgraded with the new propagation separation method and highly vectorized. In this paper, a detailed description of the new simulation algorithm is given. The code is verified by comparison with the previous experimental and simulation results by the ESRF group and new restricted geometry experiments carried out at SPring-8. PMID:26698070

  5. Electronic structure of Ni2TiAl: Theoretical aspects and Compton scattering measurement

    NASA Astrophysics Data System (ADS)

    Sahariya, Jagrati; Ahuja, B. L.

    2012-11-01

    In this paper, we report electron momentum density of Ni2TiAl alloy using an in-house 20 Ci 137Cs (661.65 keV) Compton spectrometer. The experimental data have been analyzed in terms of energy bands and density of states computed using linear combination of atomic orbitals (LCAO) method. In the LCAO computations, we have considered local density approximation, generalized gradient approximation and recently developed second order generalized gradient approximation within the frame work of density functional theory. Anisotropies in theoretical Compton profiles along [1 0 0], [1 1 0] and [1 1 1] directions are also explained in terms of energy bands.

  6. Techniques and use of a tunable, laser-based, MeV-Class Compton scattering light source

    SciTech Connect

    Albert, F; Anderson, S G; Gibson, D J; Hagmann, C A; Johnson, M S; Messerly, M; Semenov, V; Shverdin, M Y; Rusnak, B; Tremaine, A M; Hartemann, F V; Siders, C W; McNabb, D P; Barty, C P

    2009-06-30

    A Compton scattering {gamma}-ray source, capable of producing photons with energies ranging from 0.1 MeV to 0.9 MeV has been commissioned and characterized, and then used to perform nuclear resonance fluorescence (NRF) experiments. The key source parameters are the size (0.01 mm{sup 2}), horizontal and vertical divergence (6 x 10 mrad{sup 2}), duration (10 ps), spectrum and intensity (10{sup 5} photons/shot). These parameters are summarized by the peak brightness, 1.5 x 10{sup 15} photons/mm{sup 2}/mrad{sup 2}/s/0.1%bandwidth, measured at 478 keV. Additional measurements of the flux as a function of the timing difference between the drive laser pulse and the relativistic photoelectron bunch, {gamma}-ray beam profile, and background evaluations are presented. These results are systematically compared to theoretical models and computer simulations. NRF measurements performed on {sup 7}Li in LiH demonstrate the potential of Compton scattering photon sources to accurately detect isotopes in situ.

  7. High Power Experiment of X-Band Thermionic Cathode RF Gun for Compton Scattering X-ray Source

    SciTech Connect

    Sakamoto, Fumito; Uesaka, Mitsuru; Dobashi, Katsuhiro; Yamamoto, Tomohiko; Meng, De; Urakawa, Junji; Higo, Toshiyasu; Akemoto, Mitsuo; Matsuo, Kenichi; Sakae, Hisaharu; Yamamoto, Masashi

    2006-11-27

    We are currently developing a compact monochromatic X-ray source based on laser-electron collision. To realize remarkably compact-, high-intensity- and highly-stable-system, we adopt an X-band multi-bunch liner accelerator (linac) and reliable Q-switch laser. The X-ray yields by the multi-bunch electron beam and Q-switch Nd: YAG laser of 1.4 J/10 ns (FWHM) (532 nm, second harmonic) is 107 photons/RF-pulse (108 photons/sec for 10 Hz operation). The injector of the system consists of a 3.5-cell X-band thermionic cathode RF gun and an alpha magnet. So far we have achieved beam generation from the X-band thermionic cathode RF gun. The peak beam energy is 2 MeV. This experimental high energy ({approx}2 MeV) beam generation from the X-band thermionic cathode RF gun is the first in the world. In this paper, we describe the system of the Compton scattering X-ray source based on the X-band linac, experimental results of X-band thermionic cathode RF gun and the details of the experimental setup for Compton scattering X-ray generation that are under construction.

  8. Electron density of Rhizophora spp. wood using Compton scattering technique at 15.77, 17.48 and 22.16 keV XRF energies

    NASA Astrophysics Data System (ADS)

    Shakhreet, B. Z.; Bauk, S.; Shukri, A.

    2015-02-01

    Compton (incoherently) scattered photons which are directly proportional to the electron density of the scatterer, have been employed in characterizing Rhizophora spp. as breast tissue equivalent. X-ray fluorescent scattered incoherently from Rhizophora spp. sample was measured using Si-PIN detector and three XRF energy values 15.77, 17.48 and 22.16 keV. This study is aimed at providing electron density information in support of the introduction of new tissue substitute materials for mammography phantoms.

  9. Doppler Broadening Calculations of Compton Scattering for Molecules, Plastics, Tissues, and Few Biological Materials in the X-Ray Region: An Analysis in Terms of Compton Broadening and Geometrical Energy Broadening

    NASA Astrophysics Data System (ADS)

    Rao, D. V.; Cesareo, R.; Brunetti, A.; Gigante, G. E.; Akatsuka, T.; Takeda, T.; Itai, Y.

    2004-09-01

    Relativistic and nonrelativistic Compton profile cross sections for H, C, N, O, P, and Ca and for a few important biological materials such as water, polyethylene, lucite, polystyrene, nylon, polycarbonate, bakelite, fat, bone and calcium hydroxyapatite are estimated for a number of Kα x-ray energies and for 59.54 keV (Am-241) γ photons. Energy broadening and geometrical broadening (ΔG) is estimated by assuming θmin and θmax are symmetrically situated around θ=90°. FWHM of J(PZ) and FWHM of Compton energy broadening are evaluated at various incident photon energies. These values are estimated around the centroid of the Compton profile with an energy interval of 0.1 and 1.0 keV for 59.54 keV photons. Total Compton, individual shell, and Compton energy-absorption scattering cross sections are evaluated in the energy region from 0.005 to 0.5 MeV. It is an attempt to know the effect of Doppler broadening for single atoms, many of which constitute the biological materials.

  10. Electronic properties of PbCl2 and PbBr2 using Compton scattering technique.

    PubMed

    Ahmed, G; Sharma, Y; Ahuja, B L

    2009-06-01

    We present the electron momentum densities of PbCl(2) and PbBr(2) using 661.65 keV gamma-rays from 20 Ci (137)Cs source. To supplement our experimental investigations, we also report energy bands, density of states, Mulliken's population and Compton profiles of PbCl(2) and PbBr(2) using linear combination of atomic orbitals within Hartree-Fock and density functional theories. The energy bands are also computed employing full potential linearized augmented plane wave (FP-LAPW) method. Compton profiles are also analyzed in terms of equal-valence-electron-density scale. It shows that PbCl(2) is more covalent than PbBr(2), which is in agreement with the Mulliken's population analysis. It is seen that the Hartree-Fock and density functional theory based Compton line shapes show similar type of deviations from the experimental data. The luminescence properties of these halides are explained on the basis of energy band and density of states. PMID:19269187

  11. A flow cell for measuring X-ray Compton scattering of liquid at temperatures up to 623 K and pressures up to 20 MPa.

    PubMed

    Ono, Takumi; Watanabe, Masaru; Sato, Yoshiyuki; Inomata, Hiroshi; Nakahara, Koichi; Itou, Masayoshi; Sakurai, Yoshiharu

    2016-08-01

    A flow-type cell was developed for measuring Compton scattering spectra of heat-sensitive aqueous solution. Compton scattering spectra of water and ethanol were measured in the region from ambient conditions to 623 K and 20 MPa. Compton profiles derived from measurement with the flow-type cell were comparable with those in the literature. Results obtained from the flow-type cell showed that delocalization of electronic charge density of water and ethanol at high temperatures occurred. Delocalization of the electronic charge density of ethanol was greater than that of water at high temperature, which is consistent with the prior works that use proton NMR chemical shifts to describe hydrogen bonding. PMID:27587099

  12. A flow cell for measuring X-ray Compton scattering of liquid at temperatures up to 623 K and pressures up to 20 MPa

    NASA Astrophysics Data System (ADS)

    Ono, Takumi; Watanabe, Masaru; Sato, Yoshiyuki; Inomata, Hiroshi; Nakahara, Koichi; Itou, Masayoshi; Sakurai, Yoshiharu

    2016-08-01

    A flow-type cell was developed for measuring Compton scattering spectra of heat-sensitive aqueous solution. Compton scattering spectra of water and ethanol were measured in the region from ambient conditions to 623 K and 20 MPa. Compton profiles derived from measurement with the flow-type cell were comparable with those in the literature. Results obtained from the flow-type cell showed that delocalization of electronic charge density of water and ethanol at high temperatures occurred. Delocalization of the electronic charge density of ethanol was greater than that of water at high temperature, which is consistent with the prior works that use proton NMR chemical shifts to describe hydrogen bonding.

  13. Gamma rays produced by intra-cavity inverse Compton scattering of a storage ring free-electron laser

    NASA Astrophysics Data System (ADS)

    Couprie, M. E.; Nutarelli, D.; Roux, R.; Visentin, B.; Nahon, L.; Bakker, R.; Delboulbé, A.; Billardon, M.

    1999-12-01

    A collimated tunable gamma-ray beam has been generated by inverse Compton scattering of an additional positron bunch with the Super-ACO storage ring free-electron laser (FEL) positioned inside the optical resonator in the UV range (345-355 nm). This specific novel set-up ensures a natural transverse overlap and synchronization. The tunable gamma-ray beam produced covers the energy range from a few MeV up to 35 MeV, the maximum energy achievable with a FEL. The number of scattered gamma rays is relatively large (5000 000 photons/s at 800 MeV and 2000 000 photons/s at 700 MeV, i.e. the greatest value for a FEL). Furthermore, a significant number of high-energy gamma rays have also been produced by scattering of the spontaneous radiation stored in the optical cavity. The scattering is performed from a positron bunch outside the undulator, demonstrating for the first time the possibility of optimizing the yield and/or the spectrum by alteration of the stored beam without alteration of the FEL.

  14. Simple synchronization technique of a mode-locked laser for Laser-Compton scattering γ-ray source.

    PubMed

    Mori, Michiaki; Kosuge, Atsushi; Kiriyama, Hiromitsu; Hajima, Ryoichi; Kondo, Kiminori

    2016-06-01

    We propose a simple and effective synchronization technique between a reference electrical oscillator and a mode-locked laser for a narrowband picosecond Laser-Compton scattering γ-ray source by using a commercial-based 1-chip frequency synthesizer, which is widely used in radio communication. The mode-locked laser has been successfully synchronized in time with a jitter of 180 fs RMS for 10 Hz-100 kHz bandwidth. A good stability of 640 μHz at 80 MHz repetition rate for 10 h operation has also been confirmed. We discuss in detail the design and performance of this technique (in terms of timing jitter, stability, and validity). PMID:27370447

  15. Extracting the Redox Orbitals in Li Battery Materials with High-Resolution X-Ray Compton Scattering Spectroscopy

    NASA Astrophysics Data System (ADS)

    Suzuki, K.; Barbiellini, B.; Orikasa, Y.; Go, N.; Sakurai, H.; Kaprzyk, S.; Itou, M.; Yamamoto, K.; Uchimoto, Y.; Wang, Yung Jui; Hafiz, H.; Bansil, A.; Sakurai, Y.

    2015-02-01

    We present an incisive spectroscopic technique for directly probing redox orbitals based on bulk electron momentum density measurements via high-resolution x-ray Compton scattering. Application of our method to spinel LixMn2O4 , a lithium ion battery cathode material, is discussed. The orbital involved in the lithium insertion and extraction process is shown to mainly be the oxygen 2 p orbital. Moreover, the manganese 3 d states are shown to experience spatial delocalization involving 0.16 ±0.05 electrons per Mn site during the battery operation. Our analysis provides a clear understanding of the fundamental redox process involved in the working of a lithium ion battery.

  16. Extracting the Redox Orbitals in Li Battery Materials with High-Resolution X-Ray Compton Scattering Spectroscopy

    NASA Astrophysics Data System (ADS)

    Barbiellini, B.; Suzuki, K.; Orikasa, Y.; Go, N.; Sakurai, H.; Kaprzyk, S.; Itou, M.; Yamamoto, K.; Uchimoto, Y.; Wang, Yung Jui; Hafiz, H.; Bansil, A.; Sakurai, Y.

    2015-03-01

    We present an incisive spectroscopic technique for directly probing redox orbitals based on bulk electron momentum density measurements via high-resolution X-ray Compton scattering. Application of our method to spinel LixMn2O4 (a lithium ion battery cathode material) is discussed. The orbital involved in lithium insertion and extraction process is mainly the oxygen 2p orbital. Moreover, the manganese 3d states are shown to experience spatial delocalization involving 0.16 electrons per Mn site during the battery operation. Our analysis provides a clear understanding of the fundamental redox process involved in the working of the lithium ion battery. Work supported in part by the US DOE.

  17. High-energy gamma-ray beams from nonlinear Thomson and Compton scattering in the ultra-intense regime

    NASA Astrophysics Data System (ADS)

    Harvey, Christopher; Marklund, Mattias; Wallin, Erik

    2015-05-01

    We consider the Thomson and Compton scattering of high-energy electrons in an intense laser pulse. Our simulations show that energy losses due to radiation reaction cause the emitted radiation to be spread over a broader angular range than the case without these losses included. We explain this in terms of the effect of these energy losses on the particle dynamics. Finally, at ultra-high intensities, i.e. fields with a dimensionless parameter a0~200, the energy of the emission spectrum is significantly reduced by radiation reaction and also the classical and QED results begin to differ. This is found to be due to the classical theory overestimating the energy loss of the electrons. Such findings are relevant to radiation source development involving the next generation of high-intensity laser facilities.

  18. Measurement of the beam-recoil polarization in low-energy virtual Compton scattering from the proton

    NASA Astrophysics Data System (ADS)

    Doria, L.; Janssens, P.; Achenbach, P.; Ayerbe Gayoso, C.; Baumann, D.; Bensafa, I.; Benali, M.; Beričič, J.; Bernauer, J. C.; Böhm, R.; Bosnar, D.; Correa, L.; D'Hose, N.; Defaÿ, X.; Ding, M.; Distler, M. O.; Fonvieille, H.; Friedrich, J.; Friedrich, J. M.; Laveissière, G.; Makek, M.; Marroncle, J.; Merkel, H.; Mihovilovič, M.; Müller, U.; Nungesser, L.; Pasquini, B.; Pochodzalla, J.; Postavaru, O.; Potokar, M.; Ryckbosch, D.; Sánchez Majos, S.; Schlimme, B. S.; Seimetz, M.; Širca, S.; Tamas, G.; Van de Vyver, R.; Van Hoorebeke, L.; Van Overloop, A.; Walcher, Th.; Weinriefer, M.; A1 Collaboration

    2015-11-01

    Double-polarization observables in the reaction e ⃗p →e'p ⃗'γ have been measured at Q2=0.33 (GeV/c ) 2 . The experiment was performed at the spectrometer setup of the A1 Collaboration using the 855 MeV polarized electron beam provided by the Mainz Microtron (MAMI) and a recoil proton polarimeter. From the double-polarization observables the structure function PLT ⊥ is extracted for the first time, with the value (-15.4 ±3 .3(stat .)-2.4+1.5(syst.)) GeV-2 , using the low-energy theorem for virtual Compton scattering. This structure function provides a hitherto unmeasured linear combination of the generalized polarizabilities of the proton.

  19. Simple synchronization technique of a mode-locked laser for Laser-Compton scattering γ-ray source

    NASA Astrophysics Data System (ADS)

    Mori, Michiaki; Kosuge, Atsushi; Kiriyama, Hiromitsu; Hajima, Ryoichi; Kondo, Kiminori

    2016-06-01

    We propose a simple and effective synchronization technique between a reference electrical oscillator and a mode-locked laser for a narrowband picosecond Laser-Compton scattering γ-ray source by using a commercial-based 1-chip frequency synthesizer, which is widely used in radio communication. The mode-locked laser has been successfully synchronized in time with a jitter of 180 fs RMS for 10 Hz-100 kHz bandwidth. A good stability of 640 μHz at 80 MHz repetition rate for 10 h operation has also been confirmed. We discuss in detail the design and performance of this technique (in terms of timing jitter, stability, and validity).

  20. Effective atomic numbers of blue topaz at different gamma-rays energies obtained from Compton scattering technique

    SciTech Connect

    Tuschareon, S. Limkitjaroenporn, P. Kaewkhao, J.

    2014-03-24

    Topaz occurs in a wide range of colors, including yellow, orange, brown, pink-to-violet and blue. All of these color differences are due to color centers. In order to improve the color of natural colorless topaz, the most commonly used is irradiated with x- or gamma-rays, indicated that attenuation parameters is important to enhancements by irradiation. In this work, the mass attenuation coefficients of blue topaz were measured at the different energy of γ-rays using the Compton scattering technique. The results show that, the experimental values of mass attenuation coefficient are in good agreement with the theoretical values. The mass attenuation coefficients increase with the decrease in gamma rays energies. This may be attributed to the higher photon interaction probability of blue topaz at lower energy. This result is a first report of mass attenuation coefficient of blue topaz at different gamma rays energies.

  1. Effective atomic numbers of blue topaz at different gamma-rays energies obtained from Compton scattering technique

    NASA Astrophysics Data System (ADS)

    Tuschareon, S.; Limkitjaroenporn, P.; Kaewkhao, J.

    2014-03-01

    Topaz occurs in a wide range of colors, including yellow, orange, brown, pink-to-violet and blue. All of these color differences are due to color centers. In order to improve the color of natural colorless topaz, the most commonly used is irradiated with x- or gamma-rays, indicated that attenuation parameters is important to enhancements by irradiation. In this work, the mass attenuation coefficients of blue topaz were measured at the different energy of γ-rays using the Compton scattering technique. The results show that, the experimental values of mass attenuation coefficient are in good agreement with the theoretical values. The mass attenuation coefficients increase with the decrease in gamma rays energies. This may be attributed to the higher photon interaction probability of blue topaz at lower energy. This result is a first report of mass attenuation coefficient of blue topaz at different gamma rays energies.

  2. Beam Measurement of 11.424 GHz X-Band Linac for Compton Scattering X-ray Source

    SciTech Connect

    Natsui, Takuya; Mori, Azusa; Masuda, Hirotoshi; Uesaka, Mitsuru; Sakamoto, Fumito

    2010-11-04

    An inverse Compton scattering X-ray source for medical applications, consisting of an X-band (11.424 GHz) linac and Q-switched Nd:YAG laser, is currently being developed at the University of Tokyo. This system uses an X-band 3.5-cell thermionic cathode RF gun for electron beam generation. We can obtain a multi-bunch electron beam with this gun. The beam is accelerated to 30 MeV by a traveling-wave accelerating tube. So far, we have verified stable beam generation (around 2.3 MeV) by using the newly designed RF gun and we have succeeded in beam transportation to a beam dump.

  3. Development and Assessment of Compton Scattered X-Ray Technique for Bone Density Measurement In-Vivo

    NASA Astrophysics Data System (ADS)

    Kapoor, Kulvir Kumar

    A Compton Scatter X-ray Bone Densitometer for Bone Density determination in-vivo is described. The system uses a single 90 kVp quasi-continuous X-ray source and three scintillation crystal detectors--two CsI(Na) scintillators for low flux scattered beam and one plastic scintillator for high flux transmission beam. Each density determination involves four intensity measurements using digital electronics --two of transmitted beams and two of compton scattered radiation. Theoretical studies are made on the contribution from multiple scattering phenomenon which limits the precise determination of density. Preliminary studies have been made on beam hardening effects which arise due to the polychromatic nature of X-ray photon beam. A number of spectra for transmitted and scattered X-ray beams have been taken under various configurations to make some qualitative assessment of the complexity of the problem involved. The main emphasis has been on the compromise between the radiation dose to the limited area of the human subject under investigation and the statistical precision of density measurement. In -vitro measurements on non-biological samples have been made to assess the accuracy and precision of the system before performing in-vivo studies on subjects. A series of normal volunteer human subjects selected at random from among the Carleton University community has been studied to collect density data for normals. The site chosen for density measurement was in the tibia of right leg of the subject. Using linear regression, measurements were normalized to 40 yrs age & 70 kg wt for male subjects and 40 yrs age & 60 kg wt for female subjects. It is found that the bone density values thus obtained had a mean of 1.35 g/cm('3) with FWHM of 0.20 g/cm('3) for males and 0.35 g/cm('3) for females. The frequency distribution of density values showed they were skewed towards higher density from mean value and peaked at 1.48 g/cm('3) both for male and female subjects. In

  4. Compact x-ray source based on burst-mode inverse Compton scattering at 100 kHz

    NASA Astrophysics Data System (ADS)

    Graves, W. S.; Bessuille, J.; Brown, P.; Carbajo, S.; Dolgashev, V.; Hong, K.-H.; Ihloff, E.; Khaykovich, B.; Lin, H.; Murari, K.; Nanni, E. A.; Resta, G.; Tantawi, S.; Zapata, L. E.; Kärtner, F. X.; Moncton, D. E.

    2014-12-01

    A design for a compact x-ray light source (CXLS) with flux and brilliance orders of magnitude beyond existing laboratory scale sources is presented. The source is based on inverse Compton scattering of a high brightness electron bunch on a picosecond laser pulse. The accelerator is a novel high-efficiency standing-wave linac and rf photoinjector powered by a single ultrastable rf transmitter at X-band rf frequency. The high efficiency permits operation at repetition rates up to 1 kHz, which is further boosted to 100 kHz by operating with trains of 100 bunches of 100 pC charge, each separated by 5 ns. The entire accelerator is approximately 1 meter long and produces hard x rays tunable over a wide range of photon energies. The colliding laser is a Yb ∶YAG solid-state amplifier producing 1030 nm, 100 mJ pulses at the same 1 kHz repetition rate as the accelerator. The laser pulse is frequency-doubled and stored for many passes in a ringdown cavity to match the linac pulse structure. At a photon energy of 12.4 keV, the predicted x-ray flux is 5 ×1 011 photons /second in a 5% bandwidth and the brilliance is 2 ×1 012 photons /(sec mm2 mrad2 0.1 %) in pulses with rms pulse length of 490 fs. The nominal electron beam parameters are 18 MeV kinetic energy, 10 microamp average current, 0.5 microsecond macropulse length, resulting in average electron beam power of 180 W. Optimization of the x-ray output is presented along with design of the accelerator, laser, and x-ray optic components that are specific to the particular characteristics of the Compton scattered x-ray pulses.

  5. The Quantum Mechanics of Nano-Confined Water: New Cooperative Effects Revealed with Neutron and X-Ray Compton Scattering

    NASA Astrophysics Data System (ADS)

    Reiter, G. F.; Deb, Aniruddha

    2014-12-01

    Neutron Compton scattering(NCS) measurements of the momentum distribution of light ions using the Vesuvio instrument at ISIS provide a sensitive local probe of the environment of those ions. NCS measurements of the proton momentum distribution in bulk water show only small deviations from the usual picture of water as a collection of molecules, with the protons covalently bonded to an oxygen and interacting weakly, primarily electrostatically, with nearby molecules. However, a series of measurements of the proton momentum distribution in carbon nanotubes, xerogel, and Nafion show that the proton delocalizes over distances of 0.2-0.3Å when water is confined on the scale of 20Å. This delocalization must be the result of changes in the Born-Oppenheimer surface for the protons, which would imply that there are large deviations in the electron distribution from that of a collection of weakly interacting molecules. This has been observed at Spring-8 using x-ray Compton scattering. The observed deviation in the valence electron momentum distribution from that of bulk water is more than an order of magnitude larger than the change observed in bulk water as the water is heated from just above melting to just below boiling. We conclude that the protons and electrons in nano-confined water are in a qualitatively different ground state from that of bulk water. Since the properties of this state persist at room temperature, and the confinement distance necessary to observe it is comparable to the distance between the elements of biological cells, this state presumably plays a role in the functioning of those cells.

  6. Compton scattering study and electronic structure of different phases of NH4NO3

    NASA Astrophysics Data System (ADS)

    Jain, Pradeep; Sahariya, Jagrati; Ahuja, B. L.

    2013-06-01

    In this paper, we present energy bands, density of states and the nature of hydrogen bonding in different temperature-dependent phases of NH4NO3, namely phases II (357-398 K), III (305-357 K) and IV (257-305 K), using the full potential linearized augmented plane wave and linear combination of atomic orbitals (LCAO) methods. Both band structure calculations show the insulating character of the II-IV phases of NH4NO3. In addition, we have reported the isotropic Compton profile of NH4NO3(IV) measured using 661.65 keV γ-radiation from a 137Cs isotope. The experimental momentum density has been compared with that based on density functional theory (DFT) and Hartree-Fock schemes within the LCAO method. It is seen that the LCAO with hybridization of DFT and Hartree-Fock (so-called B3LYP) gives better agreement with the present Compton profile measurement.

  7. Design study for a hard X-ray source with a femto-second length by using Compton scattering at the Pohang Accelerator Laboratory

    NASA Astrophysics Data System (ADS)

    Kim, Eun-San; Kim, KyungRyul

    2016-02-01

    X-ray generation based on laser-electron Compton scattering is a method to generate a compact high-flux X-ray source. At the Pohang Accelerator Laboratory's (PAL's) fs-THz facility, 3-THz radiation has been achieved using an electron beam of 150 fs rms. To further enhance the radiation bandwidth, we present design results on X-ray generation by using Compton scattering at the facility. We show the design performance for the Compton source by using a 75-MeV electron linac with a 800-nm laser system. The Compton scattering X-ray source will be a compact facility that produces 3.1 × 107 photons in a single shot and a maximum photon energy of 130 keV. In this paper, we show the system layout and the design parameters that offers an ultra-short, high-flux hard X-ray source. We present the simulation studies to optimize the parameters of the electron beam and the X-ray pulse that was given by code CAIN.

  8. Electron Linac design to drive bright Compton back-scattering gamma-ray sources

    SciTech Connect

    Bacci, A.; Rossi, A. R.; Serafini, L.; Alesini, D.; Bellaveglia, M.; Boni, R.; Chiadroni, E.; Di Pirro, G.; Esposito, A.; Ferrario, M.; Gallo, A.; Gatti, G.; Ghigo, A.; Spataro, B.; Vaccarezza, C.; Antici, P.; Migliorati, M.; Mostacci, A.; Palumbo, L.; Cianchi, A.; and others

    2013-05-21

    The technological development in the field of high brightness linear accelerators and high energy/high quality lasers enables today designing high brilliance Compton-X and Gamma-photon beams suitable for a wide range of applications in the innovative field of nuclear photonics. The challenging requirements of this kind of source comprise: tunable energy (1-20 MeV), very narrow bandwidth (0.3%), and high spectral density (10{sup 4} photons/s/eV). We present here a study focused on the design and the optimization of an electron Linac aimed to meet the source specifications of the European Extreme Light Infrastructure-Nuclear Physics project, currently funded and seeking for an innovative machine design in order to outperform state-of-the-art facilities. We show that the phase space density of the electron beam, at the collision point against the laser pulse, is the main quality factor characterizing the Linac.

  9. GPU-accelerated 3D Bayesian image reconstruction from Compton scattered data

    NASA Astrophysics Data System (ADS)

    Nguyen, Van-Giang; Lee, Soo-Jin; Lee, Mi No

    2011-05-01

    This paper describes the development of fast Bayesian reconstruction methods for Compton cameras using commodity graphics hardware. For fast iterative reconstruction, not only is it important to increase the convergence rate, but also it is equally important to accelerate the computation of time-consuming and repeated operations, such as projection and backprojection. Since the size of the system matrix for a typical Compton camera is intractably large, it is impractical to use a conventional caching scheme that stores the pre-calculated elements of a system matrix and uses them for the calculation of projection and backprojection. In this paper we propose GPU (graphics processing unit)-accelerated methods that can rapidly perform conical projection and backprojection on the fly. Since the conventional ray-based backprojection method is inefficient for parallel computing on GPUs, we develop voxel-based conical backprojection methods using two different approximation schemes. In the first scheme, we approximate the intersecting chord length of the ray passing through a voxel by the perpendicular distance from the center to the ray. In the second scheme, each voxel is regarded as a dimensionless point rather than a cube so that the backprojection can be performed without the need for calculating intersecting chord lengths or their approximations. Our simulation studies show that the GPU-based method dramatically improves the computational speed with only minor loss of accuracy in reconstruction. With the development of high-resolution detectors, the difference in the reconstruction accuracy between the GPU-based method and the CPU-based method will eventually be negligible.

  10. Compton Gamma Ray Observatory/BATSE observations of energetic electrons scattered by cyclotron resonance with waves from powerful VLF transmitters

    NASA Technical Reports Server (NTRS)

    Datlowe, Dayton W.; Imhof, William L.

    1994-01-01

    To obtain a better understanding of the wave-particle mechanisms responsible for the loss of electrons from the radiation belts, energetic electron data from the Burst and Transient Source Experiment (BATSE) on the NASA's Compton Gamma Ray Observatory (GRO) was studied. Powerful ground-based VLF transmitters resonantly scatter electrons from the inner radiation belt onto trajectories from which they precipitate into the atmosphere as they drift eastward. 563 instances in which the satellite traversed a cloud of energetic electrons which had been scattered into quasi-trapped trajectories were identified. From the longitude distribution, it was concluded that waves from the VLF transmitter NWC at 114 deg E are the origin of 257 of the events, and waves from UMSat 44 deg E related to 45 more. In another 177 cases the electrons had drifted from the longitude of these transmitters to a location in the western hemisphere. The previously reported seasonal variation in the frequency of occurrence of cyclotron resonance interaction is confirmed with the continuous coverage provided by GRO. The frequency of occurrence of the cyclotron resonance interactions is largest before sunrise, which we attribute to the diurnal variations in the transmission VLF waves through the ionosphere. For the first time, unique very narrow sheets of electrons occurring in the aftermath of a large geomagnetic storm are reported.

  11. Magnetic Compton scattering studies of the Invar effect in Fe{sub 3}Pt

    SciTech Connect

    Yahnke, C.J.; Srajer, G.; Haeffner, D.R.; Mills, D.M.; Assoufid, L.

    1995-09-01

    The authors have measured the magnetic Compton profile (MCP) or ordered and disordered Fe{sub 3}Pt samples both above and below their Curie temperature. From these measurements, they have determined the average moment per atom at room temperature to be 2.81{micro}{sub B} {+-} 0.04{micro}{sub B} for disordered Fe{sub 3}Pt and 1.78{micro}{sub B} {+-} 0.05{micro}{sub B} for ordered Fe{sub 3}Pt. At temperatures above {Tc}, they measured a substantial reduction in the moment (0.60{micro}{sub B} {+-} 0.10{micro}{sub B} for disordered Fe{sub 3}Pt and 0.64{micro}{sub B} {+-} 0.13{micro}{sub B} for ordered Fe{sub 3}Pt) and a change in the shape of the MCP. This suggests that the mechanism behind the Invar effect in Fe{sub 3}Pt can be described by a high-spin to low-spin magnetic phase transition. The experimental MCPs for both ordered and disordered Fe{sub 3}Pt are analyzed within the framework of the Wises 2{gamma} model.

  12. Magnetic Compton scattering studies of the Invar alloy Fe{sub 3}Pt

    SciTech Connect

    Yahnke, C.J.; Srajer, G.; Haeffner, D.R.; Mills, D.M.; Assoufid, L.

    1995-02-01

    The magnetic Compton profiles (MCP) for both ordered and disordered Fe{sub 3}Pt samples have been measured above and below their Curie temperature. These measurements show that the average moment per atom at room temperature is 2.8{sub {mu}{sub B}} {plus_minus} 0.1{sub {mu}{sub B}} for disordered Fe{sub 3}Pt and 1.8{sub {mu}{sub B}} {plus_minus} 0.1{sub {mu}{sub B}} for ordered Fe{sub 3}Pt., At temperatures above {Tc}, we measured a substantial reduction in the moment (0.6{sub {mu}{sub B}} {plus_minus} 0.1{sub {mu}{sub B}} for disordered Fe{sub 3}Pt and 0.6{sub {mu}{sub B}} {plus_minus} 0.1{sub {mu}{sub B}} for ordered Fe{sub 3}Pt) and a change in the shape of the MCP. These results indicate a decrease of the d-like moment on the Fe atoms in the disordered phase. The MCP for the ordered phase shows a change in the total moment, yet the momentum distribution is substantially different and cannot be described by this analysis.

  13. Timelike Compton Scattering off the nucleon: observables and experimental perspectives for JLab at 12 GeV

    NASA Astrophysics Data System (ADS)

    Boër, Marie

    2016-03-01

    Hard exclusive processes such as photoproduction or electroproduction of photon or meson off the nucleon provide access to the Generalized Parton Distributions (GPDs), in the regime where the scattering amplitude is factorized into a hard and a soft part. GPDs contain the correlation between the longitudinal momentum fraction and the transverse spatial densities of quarks and gluons in the nucleon. Timelike Compton Scattering (TCS) correspond to the reaction γN → γ*N → e+e-N, where the photon is scattered off a quark. It is measured through its interference with the associated Bethe-Heitler process, which has the same final state. TCS allows to access the GPDs and test their universality by comparison to the results obtained with the DVCS process (eN → eγN). Also, results obtained with TCS provide additional independent constrains to the GPDs parameterization. We will present the physical motivations for TCS, with our theoretical predictions for TCS observables and their dependencies. We calculated for JLab 12 GeV energies all the single and double beam and/or target polarization observables off the proton and off the neutron. We will also present the experimental perspectives for the next years at JLab. Two proposals were already accepted at JLab: in Hall B, with the CLAS12 spectrometer, in order to measure the unpolarized cross section and in Hall A, with the SoLID spectrometer, in order to measure the unpolarized cross section and the beam spin asymmetry at high intensity. A Letter Of Intent was also submitted in order to measure the transverse target spin asymmetries in Hall C. We will discuss the merits of this different experiments and present some of the expected results.

  14. Neutron Compton scattering as a molecular characterization technique: A study on NaHF{sub 2}

    SciTech Connect

    Colognesi, D.; Pietropaolo, A.; Senesi, R.; Ramirez-Cuesta, A. J.

    2007-11-01

    Inelastic neutron scattering experiments were performed at intermediate and high momentum transfers, up to 85-90 A ring {sup -1}, to study the proton momentum distribution in polycrystalline sodium hydrogen fluoride (NaHF{sub 2}) at low temperature (below 5 K). The H mean kinetic energy was extracted and compared to the results from hydrogen-projected density of phonon states derived from intermediate momentum transfer inelastic neutron scattering and lattice dynamics simulations. A reasonable agreement between the two figures was found. In addition, relevant aspects of high momentum transfer neutron scattering from NaHF{sub 2} were explored in detail, ranging from an alternative evaluation of final state effects to the role played by the instrumental resolution and to the possibility to reconstruct the potential felt by a proton from its momentum distribution.

  15. Design of a 4.8-m ring for inverse Compton scattering x-ray source

    NASA Astrophysics Data System (ADS)

    Xu, H. S.; Huang, W. H.; Tang, C. X.; Lee, S. Y.

    2014-07-01

    In this paper we present the design of a 50 MeV compact electron storage ring with 4.8-meter circumference for the Tsinghua Thomson scattering x-ray source. The ring consists of four dipole magnets with properly adjusted bending radii and edge angles for both horizontal and vertical focusing, and a pair of quadrupole magnets used to adjust the horizontal damping partition number. We find that the dynamic aperture of compact storage rings depends essentially on the intrinsic nonlinearity of the dipole magnets with small bending radius. Hamiltonian dynamics is found to agree well with results from numerical particle tracking. We develop a self-consistent method to estimate the equilibrium beam parameters in the presence of the intrabeam scattering, synchrotron radiation damping, quantum excitation, and residual gas scattering. We also optimize the rf parameters for achieving a maximum x-ray flux.

  16. Reconstructed three-dimensional electron momentum density in lithium: A Compton scattering study

    NASA Astrophysics Data System (ADS)

    Tanaka, Yoshikazu; Sakurai, Y.; Stewart, A. T.; Shiotani, N.; Mijnarends, P. E.; Kaprzyk, S.; Bansil, A.

    2001-01-01

    The three-dimensional electron momentum density ρ(p) in Li is reconstructed via a direct Fourier transform method which is free from functional assumptions concerning the shape of ρ(p). For this purpose, 12 high-resolution Compton profiles are measured, and corresponding highly accurate computations carried out within the band theory framework. Extensive comparisons between the ρ(p)'s reconstructed from the theoretical and experimental profiles with each other and with the true (without reconstruction) underlying computed ρ(p) are used to gain insight into the accuracy of our procedures, and to delineate the effects of various parameters (filtering, resolution, etc.) on the reconstructed ρ(p). The propagation of errors is considered in detail, and a general formula appropriate for the present direct Fourier method is derived. The experimental ρ(p) (in comparison to the theoretical results) shows a substantially more smeared out break at the Fermi momentum pf, and a shift of spectral weight from below to above pf, clearly indicating the importance of electron correlation effects beyond the local-density approximation for a proper description of the ground-state momentum density. The question of deducing Fermi-surface radii in terms of the position of the inflection point in the slope of ρ(p) in the presence of finite resolution is examined at length. The experimental Fermi surface and its asphericity is in good overall accord with theoretical predictions, except that band theory predicts a bulging of the Fermi surface along the [110] direction, which is greater than seen in the measurements; however, our analysis suggests that the set of 12 directions used in the present experiments may not be optimal (in number or orientations) for observing this rather localized Fermi-surface feature.

  17. Attosecond quantum entanglement in neutron Compton scattering from water in the keV range

    NASA Astrophysics Data System (ADS)

    Chatzidimitriou-Dreismann, C. A.

    2006-11-01

    Scattering of neutrons in the 24- 150 keV incident energy range from H2O relative to that of D2O and H2O- D2O mixtures was reported very recently. Studying time-of-flight integrated intensities, the applied experimental procedure appears to be transparent and may open up a novel class of neutron experiments regarding the “anomalous” scattering from protons, firstly observed in our experiment at ISIS in the 5- 100 eV range. The keV-results were analyzed within standard theory, also including (1) multiple scattering and (2) the strong incident-energy dependence of the neutron-proton cross-section σH(E0) in this energy range. The analysis reveals a striking anomalous ratio of scattering intensity of H2O relative to that of D2O of about 20%, thus being in surprisingly good agreement with the earlier results of the original experiment at ISIS.

  18. Low-momentum-transfer nonrelativistic limit of the relativistic impulse approximation expression for Compton-scattering doubly differential cross sections and characterization of their relativistic contributions

    NASA Astrophysics Data System (ADS)

    Lajohn, L. A.

    2010-04-01

    The nonrelativistic (nr) impulse approximation (NRIA) expression for Compton-scattering doubly differential cross sections (DDCS) for inelastic photon scattering is recovered from the corresponding relativistic expression (RIA) of Ribberfors [Phys. Rev. B 12, 2067 (1975)] in the limit of low momentum transfer (q→0), valid even at relativistic incident photon energies ω1>m provided that the average initial momentum of the ejected electron is not too high, that is, scattering angle θ to 0° (θ→0°) around the Compton peak maximum. This explains the observation that it is possible to obtain an accurate Compton peak (CP) even when ω1>m using nr expressions when θ is small. For example, a 1% accuracy can be obtained when ω1=1MeV if θ<20°. However as ω1 increases into the MeV range, the maximum θ at which an accurate Compton peak can be obtained from nr expressions approaches closer to zero, because the θ at which the relativistic shift of CP to higher energy is greatest, which starts at 180° when ω1<300 keV, begins to decrease, approaching zero even though the θ at which the relativistic increase in the CP magnitude remains greatest around θ=180°. The relativistic contribution to the prediction of Compton doubly differential cross sections (DDCS) is characterized in simple terms using Ribberfors further approximation to his full RIA expression. This factorable form is given by DDCS=KJ, where K is the kinematic factor and J the Compton profile. This form makes it possible to account for the relativistic shift of CP to higher energy and the increase in the CP magnitude as being due to the dependence of J(pmin,ρrel) (where pmin is the relativistic version of the z component of the momentum of the initial electron and ρrel is the relativistic charge density) and K(pmin) on pmin. This characterization approach was used as a guide

  19. Low-momentum-transfer nonrelativistic limit of the relativistic impulse approximation expression for Compton-scattering doubly differential cross sections and characterization of their relativistic contributions

    SciTech Connect

    LaJohn, L. A.

    2010-04-15

    The nonrelativistic (nr) impulse approximation (NRIA) expression for Compton-scattering doubly differential cross sections (DDCS) for inelastic photon scattering is recovered from the corresponding relativistic expression (RIA) of Ribberfors [Phys. Rev. B 12, 2067 (1975)] in the limit of low momentum transfer (q{yields}0), valid even at relativistic incident photon energies {omega}{sub 1}>m provided that the average initial momentum of the ejected electron is not too high, that is, scattering angle {theta} to 0 deg. ({theta}{yields}0 deg.) around the Compton peak maximum. This explains the observation that it is possible to obtain an accurate Compton peak (CP) even when {omega}{sub 1}>m using nr expressions when {theta} is small. For example, a 1% accuracy can be obtained when {omega}{sub 1}=1 MeV if {theta}<20 deg. However as {omega}{sub 1} increases into the MeV range, the maximum {theta} at which an accurate Compton peak can be obtained from nr expressions approaches closer to zero, because the {theta} at which the relativistic shift of CP to higher energy is greatest, which starts at 180 deg. when {omega}{sub 1}<300 keV, begins to decrease, approaching zero even though the {theta} at which the relativistic increase in the CP magnitude remains greatest around {theta}=180 deg. The relativistic contribution to the prediction of Compton doubly differential cross sections (DDCS) is characterized in simple terms using Ribberfors further approximation to his full RIA expression. This factorable form is given by DDCS=KJ, where K is the kinematic factor and J the Compton profile. This form makes it possible to account for the relativistic shift of CP to higher energy and the increase in the CP magnitude as being due to the dependence of J(p{sub min},{rho}{sub rel}) (where p{sub min} is the relativistic version of the z

  20. Small-angle Compton scattering used to determine the depth of a radioactive source in material and to estimate gamma-ray attenuation

    NASA Astrophysics Data System (ADS)

    Oberer, R. B.; Gunn, C. A.; Chiang, L. G.

    2013-09-01

    Small-angle Compton scattering produces a familiar discontinuity in the background continuum at each gamma-ray peak in a spectrum. This discontinuity was previously considered a degradation of the spectrum that needed to be removed in order to determine the net peak count rate. This discontinuity actually contains valuable information about the amount of material between the gamma ray source and the detector. This information is useful in determining the amount of attenuation that the gamma rays undergo. Furthermore, the magnitude of the discontinuity is described by simple mathematical formulas. The use of small-angle Compton scattering was discovered while analyzing the amount of highly enriched uranium (HEU) absorbed in a concrete floor. An experiment using an HEU source and concrete tiles is presented demonstrating the agreement with theoretical predictions.

  1. A laser-Compton scattering prototype experiment at 100 MeV linac of Shanghai Institute of Applied Physics

    SciTech Connect

    Luo, W.; Fan, G. T.; Fan, G. W.; Li, Y. J.; Xu, Y.; Yang, L. F.; Xu, W.; Pan, Q. Y.; Cai, X. Z.; Chen, J. G.; Chen, Y. Z.; Guo, W.; Liu, W. H.; Lin, G. Q.; Ma, Y. G.; Shen, W. Q.; Xu, B. J.; Xu, J. Q.; Zhang, H. O.; Yan, Z.; and others

    2010-01-15

    As a prototype of the Shanghai Laser Electron Gamma Source in the Shanghai Synchrotron Radiation Facility, an x-ray source based on laser-Compton scattering (LCS) has been installed at the terminal of the 100 MeV linac of the Shanghai Institute of Applied Physics. LCS x-rays are generated by interactions between Q-switched Nd:yttrium aluminum garnet laser pulses [with wavelength of 1064 nm and pulse width of 21 ns (full width at half maximum)] and electron bunches [with energy of 108 MeV and pulse width of 0.95 ns (rms)] at an angle of 42 deg. between laser and electron beam. In order to measure the energy spectrum of LCS x-rays, a Si(Li) detector along the electron beam line axis is positioned at 9.8 m away from a LCS chamber. After background subtraction, the LCS x-ray spectrum with the peak energy of 29.1{+-}4.4|{sub stat}{+-}2.1|{sub syst} keV and the peak width (rms) of 7.8{+-}2.8|{sub stat}{+-}0.4|{sub syst} keV is observed. Normally the 100 MeV linac operates with the electron macropulse charge of 1.0 nC/pulse, and the electron and laser collision repetition rate of 20 Hz. Therefore, the total LCS x-ray flux of (5.2{+-}2.0)x10{sup 2} Hz can be achieved.

  2. A laser-Compton scattering prototype experiment at 100 MeV linac of Shanghai Institute of Applied Physics.

    PubMed

    Luo, W; Xu, W; Pan, Q Y; Cai, X Z; Chen, J G; Chen, Y Z; Fan, G T; Fan, G W; Guo, W; Li, Y J; Liu, W H; Lin, G Q; Ma, Y G; Shen, W Q; Shi, X C; Xu, B J; Xu, J Q; Xu, Y; Zhang, H O; Yan, Z; Yang, L F; Zhao, M H

    2010-01-01

    As a prototype of the Shanghai Laser Electron Gamma Source in the Shanghai Synchrotron Radiation Facility, an x-ray source based on laser-Compton scattering (LCS) has been installed at the terminal of the 100 MeV linac of the Shanghai Institute of Applied Physics. LCS x-rays are generated by interactions between Q-switched Nd:yttrium aluminum garnet laser pulses [with wavelength of 1064 nm and pulse width of 21 ns (full width at half maximum)] and electron bunches [with energy of 108 MeV and pulse width of 0.95 ns (rms)] at an angle of 42 degrees between laser and electron beam. In order to measure the energy spectrum of LCS x-rays, a Si(Li) detector along the electron beam line axis is positioned at 9.8 m away from a LCS chamber. After background subtraction, the LCS x-ray spectrum with the peak energy of 29.1+/-4.4|(stat)+/-2.1|(syst) keV and the peak width (rms) of 7.8+/-2.8|(stat)+/-0.4|(syst) keV is observed. Normally the 100 MeV linac operates with the electron macropulse charge of 1.0 nC/pulse, and the electron and laser collision repetition rate of 20 Hz. Therefore, the total LCS x-ray flux of (5.2+/-2.0) x 10(2) Hz can be achieved. PMID:20113090

  3. Photon-induced positron annihilation lifetime spectroscopy using ultrashort laser-Compton-scattered gamma-ray pulses

    SciTech Connect

    Taira, Y.; Toyokawa, H.; Kuroda, R.; Yamamoto, N.; Adachi, M.; Tanaka, S.; Katoh, M.

    2013-05-15

    High-energy ultrashort gamma-ray pulses can be generated via laser Compton scattering with 90 Degree-Sign collisions at the UVSOR-II electron storage ring. As an applied study of ultrashort gamma-ray pulses, a new photon-induced positron annihilation lifetime spectroscopy approach has been developed. Ultrashort gamma-ray pulses with a maximum energy of 6.6 MeV and pulse width of 2.2 ps created positrons throughout bulk lead via pair production. Annihilation gamma rays were detected by a BaF{sub 2} scintillator mounted on a photomultiplier tube. A positron lifetime spectrum was obtained by measuring the time difference between the RF frequency of the electron storage ring and the detection time of the annihilation gamma rays. We calculated the response of the BaF{sub 2} scintillator and the time jitter caused by the variation in the total path length of the ultrashort gamma-ray pulses, annihilation gamma rays, and scintillation light using a Monte Carlo simulation code. The positron lifetime for bulk lead was successfully measured.

  4. Photon-induced positron annihilation lifetime spectroscopy using ultrashort laser-Compton-scattered gamma-ray pulses.

    PubMed

    Taira, Y; Toyokawa, H; Kuroda, R; Yamamoto, N; Adachi, M; Tanaka, S; Katoh, M

    2013-05-01

    High-energy ultrashort gamma-ray pulses can be generated via laser Compton scattering with 90° collisions at the UVSOR-II electron storage ring. As an applied study of ultrashort gamma-ray pulses, a new photon-induced positron annihilation lifetime spectroscopy approach has been developed. Ultrashort gamma-ray pulses with a maximum energy of 6.6 MeV and pulse width of 2.2 ps created positrons throughout bulk lead via pair production. Annihilation gamma rays were detected by a BaF2 scintillator mounted on a photomultiplier tube. A positron lifetime spectrum was obtained by measuring the time difference between the RF frequency of the electron storage ring and the detection time of the annihilation gamma rays. We calculated the response of the BaF2 scintillator and the time jitter caused by the variation in the total path length of the ultrashort gamma-ray pulses, annihilation gamma rays, and scintillation light using a Monte Carlo simulation code. The positron lifetime for bulk lead was successfully measured. PMID:23742543

  5. Photon-induced positron annihilation lifetime spectroscopy using ultrashort laser-Compton-scattered gamma-ray pulses

    NASA Astrophysics Data System (ADS)

    Taira, Y.; Toyokawa, H.; Kuroda, R.; Yamamoto, N.; Adachi, M.; Tanaka, S.; Katoh, M.

    2013-05-01

    High-energy ultrashort gamma-ray pulses can be generated via laser Compton scattering with 90° collisions at the UVSOR-II electron storage ring. As an applied study of ultrashort gamma-ray pulses, a new photon-induced positron annihilation lifetime spectroscopy approach has been developed. Ultrashort gamma-ray pulses with a maximum energy of 6.6 MeV and pulse width of 2.2 ps created positrons throughout bulk lead via pair production. Annihilation gamma rays were detected by a BaF2 scintillator mounted on a photomultiplier tube. A positron lifetime spectrum was obtained by measuring the time difference between the RF frequency of the electron storage ring and the detection time of the annihilation gamma rays. We calculated the response of the BaF2 scintillator and the time jitter caused by the variation in the total path length of the ultrashort gamma-ray pulses, annihilation gamma rays, and scintillation light using a Monte Carlo simulation code. The positron lifetime for bulk lead was successfully measured.

  6. X-ray suppression in gamma-ray bursts through resonant Compton scattering

    NASA Technical Reports Server (NTRS)

    Brainerd, J. J.

    1992-01-01

    An X-ray that scatters with an electron in the first Landau level of a strong magnetic field is converted into a gamma ray. This process has a resonant cross section at X-ray energies and is therefore highly likely to occur even when the first Landau level is sparsely populated. Converted X-rays are cyclotron absorbed, maintaining the equilibrium between the cyclotron photon density and the population of the first Landau level. By suppressing a neutron star's black body emission, this mechanism can produce a gamma-ray burst with a low X-ray flux.

  7. A current generation by Compton scattering in a relativistic plasma with velocity shear and temperature gradient

    NASA Technical Reports Server (NTRS)

    Hinata, S.

    1984-01-01

    Current generation by Thomson scattering in a non-relativistic plasma with the velocity shear and the temperature gradient (Hinata and Daneshvar, 1983) is extended to a relativistic plasma by replacing Thomson cross section by the Klein-Nishina formula. Because of the energy dependence of the cross-section, a numerical rather than analytic result is presented. The present calculation may be applied to a supernova implosion where the temperature may reach several MeV and a strong differential rotation is expected. It may also find applications in the early universe, and laser-pellet interaction.

  8. Measurements of the Generalized Electric and Magnetic Polarizabilities of the Proton at Low Q{sup 2} Using the Virtual-Compton-Scattering Reaction

    SciTech Connect

    Bourgeois, P.; Shaw, J.; Hicks, R.; Hotta, A.; Miskimen, R.; Sato, Y.; Tamae, T.; Alarcon, R.; Six, E.; Bernstein, A. M.; Bertozzi, W.; Botto, T.; Casagrande, F.; Dow, K.; Farkondeh, M.; Gilad, S.; Kowalski, S.; Milner, R.; Nakagawa, I.; Sirca, S.

    2006-11-24

    The mean square polarizability radii of the proton have been measured for the first time in a virtual-Compton-scattering experiment performed at the MIT-Bates out-of-plane scattering facility. Response functions and polarizabilities obtained from a dispersion analysis of the data at Q{sup 2}=0.057 GeV{sup 2}/c{sup 2} are in agreement with O(p{sup 3}) heavy baryon chiral perturbation theory. The data support the dominance of mesonic effects in the polarizabilities.

  9. Measurements of the generalized electric and magnetic polarizabilities of the proton at low Q2 using the virtual-compton-scattering reaction.

    PubMed

    Bourgeois, P; Sato, Y; Shaw, J; Alarcon, R; Bernstein, A M; Bertozzi, W; Botto, T; Calarco, J; Casagrande, F; Distler, M O; Dow, K; Farkondeh, M; Georgakopoulos, S; Gilad, S; Hicks, R; Holtrop, M; Hotta, A; Jiang, X; Karabarbounis, A; Kirkpatrick, J; Kowalski, S; Milner, R; Miskimen, R; Nakagawa, I; Papanicolas, C N; Sarty, A J; Sirca, S; Six, E; Sparveris, N F; Stave, S; Stiliaris, E; Tamae, T; Tsentalovich, G; Tschalaer, C; Turchinetz, W; Zhou, Z-L; Zwart, T

    2006-11-24

    The mean square polarizability radii of the proton have been measured for the first time in a virtual-Compton-scattering experiment performed at the MIT-Bates out-of-plane scattering facility. Response functions and polarizabilities obtained from a dispersion analysis of the data at Q2 = 0.057 GeV2/c2 are in agreement with O(p3) heavy baryon chiral perturbation theory. The data support the dominance of mesonic effects in the polarizabilities. PMID:17155738

  10. Bright MeV-energy x-ray beams from a compact all-laser-driven inverse-Compton-scattering source

    NASA Astrophysics Data System (ADS)

    Umstadter, Donald

    2012-10-01

    Bright MeV energy x-ray beams produced by conventional inverse-Compton-scattering sources are used for nuclear physics research, but their large size (>100-m) restricts accessibility and utilization for real-world radiological applications. By developing a method to integrate a compact laser-driven accelerator with Compton scattering, we have developed a source that produces MeV energy x-rays, but with a four orders-of-magnitude increase in peak brightness, and yet has a size (< 10 m) small enough to fit in a hospital laboratory, or even on a portable platform. Our design employs two independently adjustable laser pulses---one to accelerate electrons by means of a high-gradient laser wakefield, and one to Compton scatter. The use of two separate pulses from the same high-peak-power laser system allowed us to independently optimize the electron accelerator and the Compton scattering process. It also allowed the electron bunch and scattering laser pulse to be spatially overlapped on the micron scale, and be synchronized with femtosecond timing accuracy. The resulting x-ray photon energy was peaked at 1 MeV, and reached up to 4 MeV, which is twenty times higher than from an earlier all-laser-driven Compton source with a different design [K. Ta Phuoc et al., Nature Photonics 6, 308 (2012)]. The total photon number was measured to be 2x10^7; the source size was 5 μm; and the beam divergence angle was ˜10 mrad. The measurements were found to be consistent with a theoretical model that included realistic beams. We also discuss the results of the first application of the source, namely, the diagnosis---with micron resolution---of both the radiation source size and the emittance of a laser-wakefield-accelerated electron beam. Ultrafast nuclear science can also be enabled by MeV x-ray energy combined with ultrashort pulse duration (fs).

  11. Criteria for using impulse approximation to obtain Compton scattering doubly differential cross sections

    NASA Astrophysics Data System (ADS)

    Lajohn, L. A.; Pratt, R. H.

    2013-05-01

    We find that the criterion often used for predicting when impulse approximation (IA) theory yields accurate doubly differential cross sections (DDCS), namely / q <= 1 , where is the expectation value of the momentum distribution of the bound electron and q is the magnitude of the photon momentum transfer, which is much less restrictive than the assumptions on which IA theory is based ( / q << 1), is not generally dependable. We examine the IA error Δ, where Δ = (DDCSSM - DDCSRIA) / DDCSSM (DDCSSM and DDCSRIA are the peak magnitudes for S-matrix and relativistic IA derived DDCS respectively). One striking feature is that, for a given incident photon energy ωi and nuclear charge Z, Δ goes from negative to positive as the scattering angle θ increases. Further, when / q is held constant at a value less than unity, Δ changes sign at nearly the same θ for all Z. Therefore, when θ is large or small, / q << 1 is generally required in order for IA derived DDCS to be valid, while at intermediate θ, / q ~ 1 is typically sufficient, since Δ is small. The θ at which Δ changes sign increases as / q increases.

  12. A Compton scatter camera for spectral imaging of 0.5 to 3.0 MeV gamma rays

    SciTech Connect

    Martin, J.B.

    1994-12-31

    A prototype Compton scatter camera for imaging gamma rays has been built and tested. This camera addresses unique aspects of gamma-ray imaging at nuclear industrial sites, including gamma-ray energies in the 0.5 to 3.0 MeV range and polychromatic fields. Analytic models of camera efficiency, resolution and contaminating events are developed. The response of the camera bears strong similarity to emission computed tomography devices used in nuclear medicine. A direct Fourier based algorithm is developed to reconstruct two-dimensional images of measured gamma-ray fields. Iterative ART and MLE algorithms are also investigated. The point response of the camera to gamma rays of energies from 0.5 to 2.8 MeV is measured and compared to the analytic models. The direct reconstruction algorithm is at least ten times more efficient than the iterative algorithms are also investigated. The point response of the camera to gamma rays energies from 0.5 to 2.8 MeV is measured and compared to the analytic models. The direct reconstruction algorithm is at least ten times more efficient than the iterative algorithms and produces images that are, in general, of the same quality. Measured images of several phantoms are shown. Important results include angular resolutions as low as 4.4{degrees}, reproduction of phantom size and position within 7%, and contrast recovery of 84% or better. Spectral imaging is demonstrated with independent images from a multi-energy phantom consisting of two sources imaged simultaneously.

  13. A laser-Compton scattering prototype experiment at 100 MeV linac of Shanghai Institute of Applied Physics

    NASA Astrophysics Data System (ADS)

    Luo, W.; Xu, W.; Pan, Q. Y.; Cai, X. Z.; Chen, J. G.; Chen, Y. Z.; Fan, G. T.; Fan, G. W.; Guo, W.; Li, Y. J.; Liu, W. H.; Lin, G. Q.; Ma, Y. G.; Shen, W. Q.; Shi, X. C.; Xu, B. J.; Xu, J. Q.; Xu, Y.; Zhang, H. O.; Yan, Z.; Yang, L. F.; Zhao, M. H.

    2010-01-01

    As a prototype of the Shanghai Laser Electron Gamma Source in the Shanghai Synchrotron Radiation Facility, an x-ray source based on laser-Compton scattering (LCS) has been installed at the terminal of the 100 MeV linac of the Shanghai Institute of Applied Physics. LCS x-rays are generated by interactions between Q-switched Nd:yttrium aluminum garnet laser pulses [with wavelength of 1064 nm and pulse width of 21 ns (full width at half maximum)] and electron bunches [with energy of 108 MeV and pulse width of 0.95 ns (rms)] at an angle of 42° between laser and electron beam. In order to measure the energy spectrum of LCS x-rays, a Si(Li) detector along the electron beam line axis is positioned at 9.8 m away from a LCS chamber. After background subtraction, the LCS x-ray spectrum with the peak energy of 29.1±4.4form="infix">∣stat±2.1form="infix">∣syst keV and the peak width (rms) of 7.8±2.8form="infix">∣stat±0.4form="infix">∣syst keV is observed. Normally the 100 MeV linac operates with the electron macropulse charge of 1.0 nC/pulse, and the electron and laser collision repetition rate of 20 Hz. Therefore, the total LCS x-ray flux of (5.2±2.0)×102 Hz can be achieved.

  14. Bulk Fermi surface and momentum density in heavily doped La2-xSrxCuO4 using high-resolution Compton scattering and positron annihilation spectroscopies

    NASA Astrophysics Data System (ADS)

    Al-Sawai, W.; Barbiellini, B.; Sakurai, Y.; Itou, M.; Mijnarends, P. E.; Markiewicz, R. S.; Kaprzyk, S.; Wakimoto, S.; Fujita, M.; Basak, S.; Lin, H.; Wang, Yung Jui; Eijt, S. W. H.; Schut, H.; Yamada, K.; Bansil, A.

    2012-03-01

    We have observed the bulk Fermi surface (FS) in an overdoped (x=0.3) single crystal of La2-xSrxCuO4 by using Compton scattering. A two-dimensional (2D) momentum density reconstruction from measured Compton profiles yields a clear FS signature in the third Brillouin zone along [100]. The quantitative agreement between density functional theory (DFT) calculations and momentum density experiment suggests that Fermi-liquid physics is restored in the overdoped regime. In particular the predicted FS topology is found to be in good accord with the corresponding experimental data. We find similar quantitative agreement between the measured 2D angular correlation of positron annihilation radiation (2D-ACAR) spectra and the DFT-based computations. However, 2D-ACAR does not give such a clear signature of the FS in the extended momentum space in either the theory or the experiment.

  15. High-energy photon-hadron scattering in holographic QCD

    SciTech Connect

    Nishio, Ryoichi; Watari, Taizan

    2011-10-01

    This article provides an in-depth look at hadron high-energy scattering by using gravity dual descriptions of strongly coupled gauge theories. Just like deeply inelastic scattering (DIS) and deeply virtual Compton scattering (DVCS) serve as clean experimental probes into nonperturbative internal structure of hadrons, elastic scattering amplitude of a hadron and a (virtual) photon in gravity dual can be exploited as a theoretical probe. Since the scattering amplitude at sufficiently high energy (small Bjorken x) is dominated by parton contributions (=Pomeron contributions) even in strong coupling regime, there is a chance to learn a lesson for generalized parton distribution (GPD) by using gravity dual models. We begin with refining derivation of the Brower-Polchinski-Strassler-Tan (BPST) Pomeron kernel in gravity dual, paying particular attention to the role played by the complex spin variable j. The BPST Pomeron on warped spacetime consists of a Kaluza-Klein tower of 4D Pomerons with nonlinear trajectories, and we clarify the relation between Pomeron couplings and the Pomeron form factor. We emphasize that the saddle-point value j* of the scattering amplitude in the complex j-plane representation is a very important concept in understanding qualitative behavior of the scattering amplitude. The total Pomeron contribution to the scattering is decomposed into the saddle-point contribution and at most a finite number of pole contributions, and when the pole contributions are absent (which we call saddle-point phase), kinematical variable (q,x,t)-dependence of ln(1/q) evolution and ln(1/x) evolution parameters {gamma}{sub eff} and {lambda}{sub eff} in DIS and t-slope parameter B of DVCS in HERA experiment are all reproduced qualitatively in gravity dual. All of these observations shed a new light on modeling of GPD. Straightforward application of those results to other hadron high-energy scattering is also discussed.

  16. Relativistic regimes in which Compton scattering doubly differential cross sections obtained from impulse approximation are accurate due to cancelation of errors

    NASA Astrophysics Data System (ADS)

    Lajohn, L. A.; Pratt, R. H.

    2015-05-01

    There is no simple parameter that can be used to predict when impulse approximation (IA) can yield accurate Compton scattering doubly differential cross sections (DDCS) in relativistic regimes. When Z is low, a small value of the parameter /q (where is the average initial electron momentum and q is the momentum transfer) suffices. For small Z the photon electron kinematic contribution described in relativistic S-matrix (SM) theory reduces to an expression, Xrel, which is present in the relativistic impulse approximation (RIA) formula for Compton DDCS. When Z is high, the S-Matrix photon electron kinematics no longer reduces to Xrel, and this along with the error characterized by the magnitude of /q contribute to the RIA error Δ. We demonstrate and illustrate in the form of contour plots that there are regimes of incident photon energy ωi and scattering angle θ in which the two types of errors at least partially cancel. Our calculations show that when θ is about 65° for Uranium K-shell scattering, Δ is less than 1% over an ωi range of 300 to 900 keV.

  17. Ultrahigh brilliance quasi-monochromatic MeV γ-rays based on self-synchronized all-optical Compton scattering.

    PubMed

    Yu, Changhai; Qi, Rong; Wang, Wentao; Liu, Jiansheng; Li, Wentao; Wang, Cheng; Zhang, Zhijun; Liu, Jiaqi; Qin, Zhiyong; Fang, Ming; Feng, Ke; Wu, Ying; Tian, Ye; Xu, Yi; Wu, Fenxiang; Leng, Yuxin; Weng, Xiufeng; Wang, Jihu; Wei, Fuli; Yi, Yicheng; Song, Zhaohui; Li, Ruxin; Xu, Zhizhan

    2016-01-01

    Inverse Compton scattering between ultra-relativistic electrons and an intense laser field has been proposed as a major route to generate compact high-brightness and high-energy γ-rays. Attributed to the inherent synchronization mechanism, an all-optical Compton scattering γ-ray source, using one laser to both accelerate electrons and scatter via the reflection of a plasma mirror, has been demonstrated in proof-of-principle experiments to produce a x-ray source near 100 keV. Here, by designing a cascaded laser wakefield accelerator to generate high-quality monoenergetic e-beams, which are bound to head-on collide with the intense driving laser pulse via the reflection of a 20-um-thick Ti foil, we produce tunable quasi-monochromatic MeV γ-rays (33% full-width at half-maximum) with a peak brilliance of ~3 × 10(22) photons s(-1) mm(-2) mrad(-2) 0.1% BW at 1 MeV. To the best of our knowledge, it is one order of magnitude higher than ever reported value of its kinds in MeV regime. This compact ultrahigh brilliance γ-ray source may provide applications in nuclear resonance fluorescence, x-ray radiology and ultrafast pump-probe nondestructive inspection. PMID:27405540

  18. Ultrahigh brilliance quasi-monochromatic MeV γ-rays based on self-synchronized all-optical Compton scattering

    PubMed Central

    Yu, Changhai; Qi, Rong; Wang, Wentao; Liu, Jiansheng; Li, Wentao; Wang, Cheng; Zhang, Zhijun; Liu, Jiaqi; Qin, Zhiyong; Fang, Ming; Feng, Ke; Wu, Ying; Tian, Ye; Xu, Yi; Wu, Fenxiang; Leng, Yuxin; Weng, Xiufeng; Wang, Jihu; Wei, Fuli; Yi, Yicheng; Song, Zhaohui; Li, Ruxin; Xu, Zhizhan

    2016-01-01

    Inverse Compton scattering between ultra-relativistic electrons and an intense laser field has been proposed as a major route to generate compact high-brightness and high-energy γ-rays. Attributed to the inherent synchronization mechanism, an all-optical Compton scattering γ-ray source, using one laser to both accelerate electrons and scatter via the reflection of a plasma mirror, has been demonstrated in proof-of-principle experiments to produce a x-ray source near 100 keV. Here, by designing a cascaded laser wakefield accelerator to generate high-quality monoenergetic e-beams, which are bound to head-on collide with the intense driving laser pulse via the reflection of a 20-um-thick Ti foil, we produce tunable quasi-monochromatic MeV γ-rays (33% full-width at half-maximum) with a peak brilliance of ~3 × 1022 photons s−1 mm−2 mrad−2 0.1% BW at 1 MeV. To the best of our knowledge, it is one order of magnitude higher than ever reported value of its kinds in MeV regime. This compact ultrahigh brilliance γ-ray source may provide applications in nuclear resonance fluorescence, x-ray radiology and ultrafast pump-probe nondestructive inspection. PMID:27405540

  19. Ultrahigh brilliance quasi-monochromatic MeV γ-rays based on self-synchronized all-optical Compton scattering

    NASA Astrophysics Data System (ADS)

    Yu, Changhai; Qi, Rong; Wang, Wentao; Liu, Jiansheng; Li, Wentao; Wang, Cheng; Zhang, Zhijun; Liu, Jiaqi; Qin, Zhiyong; Fang, Ming; Feng, Ke; Wu, Ying; Tian, Ye; Xu, Yi; Wu, Fenxiang; Leng, Yuxin; Weng, Xiufeng; Wang, Jihu; Wei, Fuli; Yi, Yicheng; Song, Zhaohui; Li, Ruxin; Xu, Zhizhan

    2016-07-01

    Inverse Compton scattering between ultra-relativistic electrons and an intense laser field has been proposed as a major route to generate compact high-brightness and high-energy γ-rays. Attributed to the inherent synchronization mechanism, an all-optical Compton scattering γ-ray source, using one laser to both accelerate electrons and scatter via the reflection of a plasma mirror, has been demonstrated in proof-of-principle experiments to produce a x-ray source near 100 keV. Here, by designing a cascaded laser wakefield accelerator to generate high-quality monoenergetic e-beams, which are bound to head-on collide with the intense driving laser pulse via the reflection of a 20-um-thick Ti foil, we produce tunable quasi-monochromatic MeV γ-rays (33% full-width at half-maximum) with a peak brilliance of ~3 × 1022 photons s‑1 mm‑2 mrad‑2 0.1% BW at 1 MeV. To the best of our knowledge, it is one order of magnitude higher than ever reported value of its kinds in MeV regime. This compact ultrahigh brilliance γ-ray source may provide applications in nuclear resonance fluorescence, x-ray radiology and ultrafast pump-probe nondestructive inspection.

  20. Can the cosmic x ray and gamma ray background be due to reflection of a steep power law spectrum and Compton scattering by relativistic electrons?

    NASA Technical Reports Server (NTRS)

    Zycki, Piotr T.; Zdziarski, Andrzej A.; Svensson, Roland

    1991-01-01

    We reconsider the recent model for the origin in the cosmic X-ray and gamma-ray background by Rogers and Field. The background in the model is due to an unresolved population of AGNs. An individual AGN spectrum contains three components: a power law with the energy index of alpha = 1.1, an enhanced reflection component, and a component from Compton scattering by relativistic electrons with a low energy cutoff at some minimum Lorentz factor, gamma(sub min) much greater than 1. The MeV bump seen in the gamma-ray background is then explained by inverse Compton emission by the electrons. We show that the model does not reproduce the shape of the observed X-ray and gamma-ray background below 10 MeV and that it overproduces the background at larger energies. Furthermore, we find the assumptions made for the Compton component to be physically inconsistent. Relaxing the inconsistent assumptions leads to model spectra even more different from that of the observed cosmic background. Thus, we can reject the hypothesis that the high-energy cosmic background is due to the described model.

  1. Measurement of the Generalized Polarizabilities of the Proton in Virtual Compton Scattering at Q2=0.92 and 1.76 Gev2: II. Dispersion Relation Analysis

    SciTech Connect

    Geraud Laveissiere; Luminita Todor; Natalie Degrande; S. Jaminion; Christophe Jutier; Rachele Di Salvo; L. Van Hoorebeke; et. Al.

    2003-12-01

    Virtual Compton Scattering is studied at the Thomas Jefferson National Accelerator Facility in the energy domain below pion threshold and in the Delta(1232) resonance region. The data analysis is based on the Dispersion Relation (DR) approach. The electric and magnetic Generalized Polarizabilities (GPs) of the proton and the structure functions Pll-Ptt/epsilon and Plt are determined at four-momentum transfer squared Q2=0.92 and 1.76 GeV2. The DR analysis is consistent with the low-energy expansion analysis. The world data set indicates that neither the electric nor magnetic GP follows a simple dipole form.

  2. The Penrose photoproduction scenario for NGC 4151: A black hole gamma-ray emission mechanism for active galactic nuclei and Seyfert galaxies. [Compton scattering and pair production

    NASA Technical Reports Server (NTRS)

    Leiter, D.

    1979-01-01

    A consistent theoretical interpretation is given for the suggestion that a steepening of the spectrum between X-ray and gamma ray energies may be a general, gamma-ray characteristic of Seyfert galaxies, if the diffuse gamma ray spectrum is considered to be a superposition of unresolved contributions, from one or more classes of extragalactic objects. In the case of NGC 4151, the dominant process is shown to be Penrose Compton scattering in the ergosphere of a Kerr black hole, assumed to exist in the Seyfert's active galactic nucleus.

  3. Measurements of Polarization Transfers in Real Compton Scattering by a proton target at JLAB. A new source of information on the 3D shape of the nucleon

    SciTech Connect

    Fanelli, Cristiano V.

    2015-03-01

    In this thesis work, results of the analysis of the polarization transfers measured in real Compton scattering (RCS) by the Collaboration E07-002 at the Je fferson Lab Hall-C are presented. The data were collected at large scattering angle (theta_cm = 70deg) and with a polarized incident photon beam at an average energy of 3.8 GeV. Such a kind of experiments allows one to understand more deeply the reaction mechanism, that involves a real photon, by extracting both Compton form factors and Generalized Parton Distributions (GPDs) (also relevant for possibly shedding light on the total angular momentum of the nucleon). The obtained results for the longitudinal and transverse polarization transfers K_LL and K_LT, are of crucial importance, since they confirm unambiguously the disagreement between experimental data and pQCD prediction, as it was found in E99-114 experiment, and favor the Handbag mechanism. The E99-114 and E07-002 results can contribute to attract new interest on the great yield of the Compton scattering by a nucleon target, as demonstrated by the recent approval of an experimental proposal submitted to the Jefferson Lab PAC 42 for a Wide-angle Compton Scattering experiment, at 8 and 10 GeV Photon Energies. The new experiments approved to run with the updated 12 GeV electron beam at JLab, are characterized by much higher luminosities, and a new GEM tracker is under development to tackle the challenging backgrounds. Within this context, we present a new multistep tracking algorithm, based on (i) a Neural Network (NN) designed for a fast and efficient association of the hits measured by the GEM detector which allows the track identification, and (ii) the application of both a Kalman filter and Rauch-Tung-Striebel smoother to further improve the track reconstruction. The full procedure, i.e. NN and filtering, appears very promising, with high performances in terms of both association effciency and reconstruction accuracy, and these preliminary results will

  4. On the inverse Compton scattering interpretation of the hard X-ray excesses in galaxy clusters: the case of Ophiuchus

    NASA Astrophysics Data System (ADS)

    Colafrancesco, S.; Marchegiani, P.

    2009-08-01

    Context: Populations of high energy electrons can produce hard X-ray (HXR) emission in galaxy clusters by up-scattering CMB photons via the inverse Compton scattering (ICS) mechanism. However, this scenario has various astrophysical consequences. Aims: We discuss here the consequences of the presence of a population of high energy particles for the multi-frequency emissivity of the same clusters and the structure of their atmospheres. Methods: We derive predictions for the ICS HXR emission in the specific case of the Ophiuchus cluster (for which an interesting combination of observational limits and theoretical scenarios have been presented) for three main scenarios producing high-E electrons: primary cosmic ray model, secondary cosmic rays model and neutralino DM annihilation scenario. We further discuss the predictions of the Warming Ray model for the cluster atmosphere. Under the assumption to fit the HXR emission observed in Ophiuchus, we explore the consequences that these electron populations induce on the cluster atmosphere. Results: We find that: i) primary electrons can be marginally consistent with the available data provided that the electron spectrum is cutoff at E ≲ 30 and E ≲ 90 MeV for electron spectral index values of 3.5 and 4.4, respectively; ii) secondary electron models from pp collisions are strongly inconsistent with the viable gamma-ray limits, cosmic ray protons produce too much heating of the intracluster (IC) gas and their pressure at the cluster center largely exceeds the thermal one; iii) secondary electron models from DM annihilation are also strongly inconsistent with the viable gamma-ray and radio limits, and electrons produce too much heating of the IC gas at the cluster center, unless the neutralino annihilation cross-section is much lower than the proposed value. In that case, however, these models no longer reproduce the HXR excess in Ophiuchus. Conclusions: We conclude that ICS by secondary electrons from both neutralino DM

  5. 500 MW X-Band RF System of a 0.25 GeV Electron LINAC for Advanced Compton Scattering Source Application

    SciTech Connect

    Chu, Tak Sum; Anderson, Scott; Barty, Christopher; Gibson, David; Hartemann, Fred; Marsh, Roark; Siders, Craig; Adolphsen, Chris; Jongewaard, Erik; Raubenheimer, Tor; Tantawi, Sami; Vlieks, Arnold; Wang, Juwen; /SLAC

    2012-07-03

    A Mono-Energetic Gamma-Ray (MEGa-Ray) Compton scattering light source is being developed at LLNL in collaboration with the SLAC National Accelerator Laboratory. The electron beam for the Compton scattering interaction will be generated by a X-band RF gun and a X-band LINAC at the frequency of 11.424 GHz. High power RF in excess of 500 MW is needed to accelerate the electrons to energy of 250 MeV or greater for the interaction. Two high power klystron amplifiers, each capable of generating 50 MW, 1.5 msec pulses, will be the main high power RF sources for the system. These klystrons will be powered by state of the art solid-state high voltage modulators. A RF pulse compressor, similar to the SLED II pulse compressor, will compress the klystron output pulse with a power gain factor of five. For compactness consideration, we are looking at a folded waveguide setup. This will give us 500 MW at output of the compressor. The compressed pulse will then be distributed to the RF gun and to six traveling wave accelerator sections. Phase and amplitude control are located at the RF gun input and additional control points along the LINAC to allow for parameter control during operation. This high power RF system is being designed and constructed. In this paper, we will present the design, layout, and status of this RF system.

  6. 500 MW X-BAND RF SYSTEM OF A 0.25 GEV ELECTRON LINAC FOR ADVANCED COMPTON SCATTERING SOURCE APPLICATION

    SciTech Connect

    Chu, T S; Anderson, S G; Gibson, D J; Hartemann, F V; Marsh, R A; Siders, C; Barty, C P; Adolphsen, C; Jongewaard, E; Tantawi, S; Vlieks, A; Wang, J W; Raubenheimer, T

    2010-05-12

    A Mono-Energetic Gamma-Ray (MEGa-Ray) Compton scattering light source is being developed at LLNL in collaboration with SLAC National Accelerator Laboratory. The electron beam for the Compton scattering interaction will be generated by a X-band RF gun and a X-band LINAC at the frequency of 11.424 GHz. High power RF in excess of 500 MW is needed to accelerate the electrons to energy of 250 MeV or greater for the interaction. Two high power klystron amplifiers, each capable of generating 50 MW, 1.5 msec pulses, will be the main high power RF sources for the system. These klystrons will be powered by state of the art solid-state high voltage modulators. A RF pulse compressor, similar to the SLED II pulse compressor, will compress the klystron output pulse with a power gain factor of five. For compactness consideration, we are looking at a folded waveguide setup. This will give us 500 MW at output of the compressor. The compressed pulse will then be distributed to the RF gun and to six traveling wave accelerator sections. Phase and amplitude control are located at the RF gun input and additional control points along the LINAC to allow for parameter control during operation. This high power RF system is being designed and constructed. In this paper, we will present the design, layout, and status of this RF system.

  7. The Angular Momentum Structure of the Nucleon

    SciTech Connect

    Nowak, Wolf-Dieter

    2008-10-13

    The proton spin budget is discussed. Results are presented from inclusive and semi-inclusive deep inelastic scattering and from deeply virtual Compton scattering. They permit interpretations towards the determination of various contributions to the proton spin.

  8. Evaluation of Compton attenuation and photoelectric absorption coefficients by convolution of scattering and primary functions and counts ratio on energy spectra

    PubMed Central

    Ashoor, Mansour; Asgari, Afrouz; Khorshidi, Abdollah; Rezaei, Ali

    2015-01-01

    Purpose: Estimation of Compton attenuation and the photoelectric absorption coefficients were explored at various depths. Methods: A new method was proposed for estimating the depth based on the convolution of two exponential functions, namely convolution of scattering and primary functions (CSPF), which the convolved result will conform to the photopeak region of energy spectrum with the variable energy-window widths (EWWs) and a theory on the scattering cross-section. The triple energy-windows (TEW) and extended triple energy-windows scatter correction (ETEW) methods were used to estimate the scattered and primary photons according to the energy spectra at various depths due to a better performance than the other methods in nuclear medicine. For this purpose, the energy spectra were employed, and a distinct phantom along with a technetium-99 m source was simulated by Monte Carlo method. Results: The simulated results indicate that the EWW, used to calculate the scattered and primary counts in terms of the integral operators on the functions, was proportional to the depth as an exponential function. The depth will be calculated by the combination of either TEW or ETEW and proposed method resulting in the distinct energy-window. The EWWs for primary photons were in good agreement with those of scattered photons at the same as depths. The average errors between these windows for both methods TEW, and ETEW were 7.25% and 6.03% at different depths, respectively. The EWW value for functions of scattered and primary photons was reduced by increasing the depth in the CSPF method. Conclusions: This coefficient may be an index for the scattering cross-section. PMID:26170567

  9. Comment on "Evidence for narrow resonant structures at W ≈1.68 GeV and W ≈1.72 GeV in real Compton scattering off the proton"

    NASA Astrophysics Data System (ADS)

    Werthmüller, D.; Witthauer, L.; Glazier, D. I.; Krusche, B.

    2015-12-01

    We comment on the statement by Kuznetsov et al. that the structure around W =1.72 GeV seen in the beam asymmetry in Compton scattering off the proton is not observed in the total cross section of η photoproduction on the neutron.

  10. DESIGN OF A 250 MeV, X-BAND PHOTOINJECTOR LINAC FOR A PRECISION COMPTON-SCATTERING BASED GAMMA-RAY SOURCE

    SciTech Connect

    Anderson, S G; Albert, F; Gibson, D J; McNabb, D; Messerly, M; Rusnak, B; Shverdin, M; Hartemann, F V; Siders, C W; Barty, C J; Tantawi, S; Vlieks, A

    2009-05-07

    We present a compact, X-band, high-brightness accelerator design suitable for driving a precision gamma-ray source. Future applications of gamma-rays generated by Compton-scattering of laser and relativistic electron beams place stringent demands on the brightness and stability of the incident electron beam. This design identifies the beam parameters required for gamma-ray production, including position, and pointing stability. The design uses an emittance compensated, 11.4 GHz photo-gun and linac to generate 400 pC, 1-2 mm-mrad electron bunches at up to 250 MeV and 120 Hz repetition rate. The effects of jitter in the RF power system are analyzed as well as structure and optic misalignments. Finally, strategies for the mitigation of on-axis Bremsstrahlung noise are discussed.

  11. In-line phase-contrast imaging of a biological specimen using a compact laser-Compton scattering-based x-ray source

    SciTech Connect

    Ikeura-Sekiguchi, H.; Kuroda, R.; Yasumoto, M.; Toyokawa, H.; Koike, M.; Yamada, K.; Sakai, F.; Mori, K.; Maruyama, K.; Oka, H.; Kimata, T.

    2008-03-31

    Laser-Compton scattering (LCS) x-ray sources have recently attracted much attention for their potential use at local medical facilities because they can produce ultrashort pulsed, high-brilliance, and quasimonochromatic hard x rays with a small source size. The feasibility of in-line phase-contrast imaging for a 'thick' biological specimens of rat lumbar vertebrae using the developed compact LCS-X in AIST was investigated for the promotion of clinical imaging. In the higher-quality images, anatomical details of the spinous processes of the vertebrae are more clearly observable than with conventional absorption radiography. The results demonstrate that phase-contrast radiography can be performed using LCS-X.

  12. Measurement of the Generalized Polarizabilities of the Proton in Virtual Compton Scattering at Q2= 0.92 and 1.76 GeV2

    SciTech Connect

    Geraud Laveissiere; Natalie Degrande; Stephanie Jaminion; Christophe Jutier; Luminita Todor; Rachele Di Salvo; L. Van Hoorebeke; Et. Al.

    2004-09-01

    We report a Virtual Compton Scattering study of the proton at low CM energies. We have determined the structure functions P{sub LL} - P{sub TT}/{epsilon} and P{sub LT}, and the electric and magnetic Generalized Polarizabilities (GPs) {alpha}{sub E}(Q{sup 2}) and {beta}{sub M}(Q{sup 2}) at momentum transfer Q{sup 2} = 0.92 and 1.76 GeV{sup 2}. The electric GP shows a strong fall-off with Q{sup 2}, and its global behavior does not follow a simple dipole form. The magnetic GP shows a rise and then a fall-off; this can be interpreted as the dominance of a long-distance diamagnetic pion cloud at low Q{sup 2}, compensated at higher Q{sup 2} by a paramagnetic contribution from {pi}N intermediate states.

  13. Virtual Compton Scattering and the Generalized Polarizabilities of the Proton at Q^2=0.92 and 1.76 GeV^2

    SciTech Connect

    Helene Fonvieille, Geraud Laveissiere, Natalie Degrande, Stephanie Jaminion, Christophe Jutier, Luminita Todor, L. Van Hoorebeke, Bryon Anderson, Konrad Aniol, Kathleen Arundell, Gerard Audit, Leonard Auerbach, F. Baker, Maud Baylac, J. Berthot, Pierre Bertin, William Bertozzi, Louis Bimbot, Werner Boeglin, Edward Brash, Vincent Breton, Herbert Breuer, Etienne Burtin, John Calarco, Lawrence Cardman, Christian Cavata, Jian-Ping Chen, Eugene Chudakov, Evaristo Cisbani, Daniel Dale, Cornelis De Jager, Raffaele De Leo, Alexandre Deur, Nicole D'Hose, Gail Dodge, John Domingo, Latifa Elouadrhiri, Martin Epstein, Lars Ewell, John Finn, Kevin Fissum, Guy Fournier, Bernhard Frois, Salvatore Frullani, Christophe Furget, Haiyan Gao, Juncai Gao, Franco Garibaldi, Ashot Gasparian, Shalev Gilad, Ronald Gilman, Oleksandr Glamazdin, Charles Glashausser, Javier Gomez, Viktor Gorbenko, Pierre Guichon, Jens-Ole Hansen, Richard Holmes, Maurik Holtrop, Calvin Howell, Garth Huber, Charles Hyde, Sebastien Incerti, Mauro Iodice, Johann Jardillier, Mark Jones, Seigo Kato, James Kelly, Armen Ketikyan, Mohammad Khayat, Kouichi Kino, Serge Kox, Laird Kramer, Krishna Kumar, Gerfried Kumbartzki, Michael Kuss, Antonio Leone, John LeRose, Richard Lindgren, Nilanga Liyanage, George Lolos, Kazushige Maeda, Sergey Malov, D. Manley, Claude Marchand, Dominique Marchand, Demetrius Margaziotis, Pete Markowitz, Jacques Marroncle, Jacques Martino, Kathy McCormick, James McIntyre, Surik Mehrabyan, Fernand Merchez, Zein-Eddine Meziani, Robert Michaels, Jean Mougey, Sirish Nanda, Amra Offermann, Zisis Papandreou, Charles Perdrisat, R. Perrino, Gerassimos Petratos, Stephane Platchkov, Roman Pomatsalyuk, David Prout, Vina Punjabi, Thierry Pussieux, Gilles Quemener, Ronald Ransome, Oliver Ravel, Jean-Sebastien Real, Yves Roblin, David Rowntree, Gary Rutledge, Paul Rutt, Arunava Saha, Teijiro Saito, Adam Sarty, Tim Smith, Paul Souder, Riad Suleiman, Jeffrey Templon, Tatsuo Terasawa, Raphael Tieulent, Egle Tomasi, Hiroaki Tsubota, Hiroaki Ueno, Paul Ulmer, Guido Urciuoli, Marc Vanderhaeghen, Rob van der Meer, R.Van De Vyver, Pascal Vernin, Branislav Vlahovic, Hakob Voskanyan, Eric Voutier, John Watson, Lawrence Weinstein, Krishni Wijesooriya, Richard Wilson, Bogdan Wojtsekhowski, Dan Zainea, Zilu Zhou, Rachele Di Salvo

    2012-07-01

    Virtual Compton Scattering (VCS) on the proton has been studied at Jefferson Lab using the exclusive photon electroproduction reaction (e p --> e p gamma). This paper gives a detailed account of the analysis which has led to the determination of the structure functions P{sub LL}-P{sub TT}/epsilon and P{sub LT}, and the electric and magnetic generalized polarizabilities (GPs) alpha{sub E}(Q{sup 2}) and beta{sub M}(Q{sup 2}) at values of the four-momentum transfer squared Q{sup 2} = 0.92 and 1.76 GeV{sup 2}. These data, together with the results of VCS experiments at lower momenta, help building a coherent picture of the electric and magnetic GPs of the proton over the full measured Q{sup 2}-range, and point to their non-trivial behavior.

  14. Poster — Thur Eve — 01: The effect of the number of projections on MTF and CNR in Compton scatter tomography

    SciTech Connect

    Chighvinadze, T; Pistorius, S

    2014-08-15

    Purpose: To investigate the dependence of the reconstructed image quality on the number of projections in multi-projection Compton scatter tomography (MPCST). The conventional relationship between the projection number used for reconstruction and reconstructed image quality pertained to CT does not necessarily apply to MPCST, which can produce images from a single projection if the detectors have sufficiently high energy and spatial resolution. Methods: The electron density image was obtained using filtered-backprojection of the scatter signal over circular arcs formed using Compton equation. The behavior of the reconstructed image quality as a function of the projection number was evaluated through analytical simulations and characterized by CNR and MTF. Results: The increase of the projection number improves the contrast with this dependence being a function of fluence. The number of projections required to approach the asymptotic maximum contrast decreases as the fluence increases. Increasing projection number increases the CNR but not spatial resolution. Conclusions: For MPCST using a 500eV energy resolution and a 2×2mm{sup 2} size detector, an adequate image quality can be obtained with a small number of projections provided the incident fluence is high enough. This is conceptually different from conventional CT where a minimum number of projections is required to obtain an adequate image quality. While increasing projection number, even for the lowest dose value, the CNR increases even though the number of photons per projection decreases. The spatial resolution of the image is improved by increasing the sampling within a projection rather than by increasing the number of projections.

  15. SU-F-18C-05: Characterization of a Silicon Strip Photon-Counting Detector in the Presence of Compton Scatter: A Simulation Study

    SciTech Connect

    Ziemer, B; Ding, H; Cho, H

    2014-06-15

    Purpose: To investigate the effect of Compton scatter on detection efficiency and charge-sharing for a Si strip photon-counting detector as a function of pixel pitch, slice thickness and total pixel length. Methods: A CT imaging system employing a silicon photon-counting detector was implemented using the GATE Monte Carlo package. A focal spot size of 300 µm, magnification of 1.33, and pixel pitches of 0.1 and 0.5mm were initially investigated. A 60 kVp spectrum with 3 mm Al filter was used and energy spectral degradation based on a prototype detector was simulated. To study charge-sharing, a single pixel was illuminated, and the detector response in neighboring pixels was investigated. A longitudinally semiinfinite detector was simulated to optimize the quantum detection efficiency of the imaging system as a function of pixel pitch, slice thickness and depth of interaction. A 2.5 mm thick tungsten plate with a 0.01 mm by 1.5 mm slit was implemented to calculate the modulation transfer function (MTF) from projection-based images. A threshold of 15 keV was implemented in the detector simulation. The preliminary charge sharing investigation results considered only scattering effects and the detector electronics related factors were neglected. Results: Using a 15 keV threshold, 1% of the pixel charge migrated into neighboring pixels with a pixel size of 0.1×0.1 mm{sup 2}. The quantum detection efficiency was 77%, 84%, 87% and 89% for 15 mm, 22.5 mm, 30 mm, and 45 mm length silicon detector pixels, respectively. For a pixel pitch of 0.1 mm, the spatial frequency at 10% of the maximum MTF was found to be 5.2 lp/mm. This agreed with an experimental MTF measurement of 5.3 lp/mm with a similar detector configuration. Conclusion: Using optimized design parameters, Si strip photon-counting detectors can offer high detection efficiency and spatial resolution even in the presence of Compton scatter.

  16. Refinement of the Compton-Rayleigh scatter ratio method for use on the Mars Science Laboratory alpha particle X-ray spectrometer: II - Extraction of invisible element content

    NASA Astrophysics Data System (ADS)

    Perrett, Glynis M.; Campbell, John L.; Gellert, Ralf; King, Penelope L.; Nield, Emily; O'Meara, Joanne M.; Pradler, Irina

    2016-02-01

    The intensity ratio C/R between Compton and Rayleigh scatter peaks of the exciting Pu L X-rays in the alpha particle X-ray spectrometer (APXS) is strongly affected by the presence of very light elements such as oxygen which cannot be detected directly by the APXS. C/R values are determined along with element concentrations by fitting APXS spectra of geochemical reference materials (GRMs) with the GUAPX code. A quantity K is defined as the ratio between the C/R value determined by Monte Carlo simulation based on the measured element concentrations and the fitted C/R value from the spectrum. To ensure optimally accurate K values, the choice of appropriate GRMs is explored in detail, with attention paid to Rb and Sr, whose characteristic Kα X-ray peaks overlap the Pu Lα scatter peaks. The resulting relationship between the ratio K and the overall oxygen fraction is linear. This provides a calibration from which the concentration of additional light invisible constituents (ALICs) such as water may be estimated in unknown rock and conglomerate samples. Several GRMs are used as 'unknowns' in order to evaluate the accuracy of ALIC concentrations derived in this manner.

  17. INVERSE COMPTON SCATTERING MODEL FOR X-RAY EMISSION OF THE GAMMA-RAY BINARY LS 5039

    SciTech Connect

    Yamaguchi, M. S.; Takahara, F.

    2012-12-20

    We propose a model for the gamma-ray binary LS 5039 in which the X-ray emission is due to the inverse Compton (IC) process instead of the synchrotron radiation. Although the synchrotron model has been discussed in previous studies, it requires a strong magnetic field which leads to a severe suppression of the TeV gamma-ray flux in conflict with H.E.S.S. observations. In this paper, we calculate the IC emission by low energy electrons ({gamma}{sub e} {approx}< 10{sup 3}) in the Thomson regime. We find that IC emission of the low energy electrons can explain the X-ray flux and spectrum observed with Suzaku if the minimum Lorentz factor of injected electrons {gamma}{sub min} is around 10{sup 3}. In addition, we show that the Suzaku light curve is well reproduced if {gamma}{sub min} varies in proportion to the Fermi flux when the distribution function of injected electrons at higher energies is fixed. We conclude that the emission from LS 5039 is well explained by the model with the IC emission from electrons whose injection properties are dependent on the orbital phase. Since the X-ray flux is primarily determined by the total number of cooling electrons, this conclusion is rather robust, although some mismatches between the model and observations at the GeV band remain in the present formulation.

  18. Compton scattering from C12 using tagged photons in the energy range 65-115 MeV

    NASA Astrophysics Data System (ADS)

    Myers, L. S.; Shoniyozov, K.; Preston, M. F.; Anderson, M. D.; Annand, J. R. M.; Boselli, M.; Briscoe, W. J.; Brudvik, J.; Capone, J. I.; Feldman, G.; Fissum, K. G.; Hansen, K.; Henshaw, S. S.; Isaksson, L.; Jebali, R.; Kovash, M. A.; Lewis, K.; Lundin, M.; MacGregor, I. J. D.; Middleton, D. G.; Mittelberger, D. E.; Murray, M.; Nathan, A. M.; Nutbeam, S.; O'Rielly, G. V.; Schröder, B.; Seitz, B.; Stave, S. C.; Weller, H. R.; Compton@Max-Lab Collaboration

    2014-03-01

    Elastic scattering of photons from C12 has been investigated using quasimonoenergetic tagged photons with energies in the range 65-115 MeV at laboratory angles of 60∘, 120∘, and 150∘ at the Tagged-Photon Facility at the MAX IV Laboratory in Lund, Sweden. A phenomenological model was employed to provide an estimate of the sensitivity of the 12C(γ ,γ)12C cross section to the bound-nucleon polarizabilities.

  19. A search for the Sunyaev-Zel'dovich effect at millimeter wavelengths. [cosmic background photon energy increase due to Compton scattering by high temperature galactic cluster plasma electrons

    NASA Technical Reports Server (NTRS)

    Meyer, S. S.; Jeffries, A. D.; Weiss, R.

    1983-01-01

    It is believed that X-ray emission from clusters of galaxies represents thermal bremsstrahlung from a hot plasma. According to Sunyaev and Zel'dovich (1972), the plasma column density and temperature derived from this model imply a measurable distortion of the cosmic background radiation (CBR) in the cluster direction. This distortion results from the Compton scattering of the CBR photons by the electrons in the plasma, resulting in an average increase of each photon. This process, known as the Sunyaev-Zel'dovich effect, is photon conserving and 'shifts' the CBR spectrum to higher frequencies. The result is a decrease of flux at frequencies below 7.5 per cm (the Rayleigh-Jeans region), and an increase above. The investigation is concerned with measurements of the Sunyaev-Zel'dovich effect at frequencies in the range from 3 to 10 per cm. Attention is given to the employed observing and analysis technique, and an initial null result for the cluster Abell 1795.

  20. A new transportable instrument for in-situ void and corrosion imaging in thick structural sections by three dimensional Compton scatter imaging

    NASA Astrophysics Data System (ADS)

    Bridge, B.

    2000-05-01

    When X Gamma or other kinds of subatomic particle radiation are being used for NDE, measurements are almost always made on the primary beam after transmission through the object under test. Cases are described where better results, i.e., image quality or cost effectiveness can be obtained from measurements on scattered radiation rather than the primary beam. Compton imaging of high volume resolution in thick structures has previously been achieved only by fixed laboratory installations involving massive primary beam shields (collimators) between source and detectors. Here the design of a relatively portable collimator (98 kg mass) for a cobalt 60 source is given. It permits three dimensional material density imaging, with voxel (3-dimensional pixel) volumes small enough to permit the detection of voids down to 10 cubic mm in up to 30 mm thickness of steel or 250 mm of wood (for example, a 500 mm diameter tree trunk). Using a 370 GBq source, typical results of thickness measurements to a precision of 1 mm over cross sections down to 10 square mm are presented. The collimator mass is reducible to about 68 kg with the use of depleted uranium instead of lead. The means of deploying such a collimator in a mobile way are discussed. A typical in-situ application is the detection of inner wall corrosion and flooding of tubular members of underwater offshore oil platforms and ship hulls without the need to remove hard marine growth. Another case is the detection of telegraph pole and tree rot below ground level.

  1. Visual understanding of the hidden-order transition in URu2Si2 by high-resolution x-ray Compton scattering

    NASA Astrophysics Data System (ADS)

    Koizumi, Akihisa; Kubo, Yasunori; Motoyama, Gaku; Yamamura, Tomoo; Itou, Masayoshi; Sakurai, Yoshiharu

    2015-09-01

    We report the change of electronic structure associated with the hidden-order (HO) transition in URu2Si2 through Compton scattering experiment on the (001) plane of the single crystal. The two-dimensional electron occupation number densities (EONDs) obtained at 14 and 20 K, which are the projection of Fermi volume onto the kx-ky plane of the first Brillouin zone, clearly reflect a whole image of electronic structure in the HO and paramagnetic (PM) phases, respectively. The change in electronic structure is well described by theoretical EONDs derived from the result of a band calculation, where U 5 f electrons are treated as itinerant ones. We also evaluate the electron (hole) numbers in the HO and PM phases and, therefore, its change on the HO transition. The HO transition is deeply involved with a significant change in 5 f electrons from partially localized to itinerant states through hybridization with conduction electrons, resulting in the reconstruction of Fermi-surface structure.

  2. An iterative three-dimensional electron density imaging algorithm using uncollimated Compton scattered x rays from a polyenergetic primary pencil beam

    SciTech Connect

    Van Uytven, Eric; Pistorius, Stephen; Gordon, Richard

    2007-01-15

    X-ray film-screen mammography is currently the gold standard for detecting breast cancer. However, one disadvantage is that it projects a three-dimensional (3D) object onto a two-dimensional (2D) image, reducing contrast between small lesions and layers of normal tissue. Another limitation is its reduced sensitivity in women with mammographically dense breasts. Computed tomography (CT) produces a 3D image yet has had a limited role in mammography due to its relatively high dose, low resolution, and low contrast. As a first step towards implementing quantitative 3D mammography, which may improve the ability to detect and specify breast tumors, we have developed an analytical technique that can use Compton scatter to obtain 3D information of an object from a single projection. Imaging material with a pencil beam of polychromatic x rays produces a characteristic scattered photon spectrum at each point on the detector plane. A comparable distribution may be calculated using a known incident x-ray energy spectrum, beam shape, and an initial estimate of the object's 3D mass attenuation and electron density. Our iterative minimization algorithm changes the initially arbitrary electron density voxel matrix to reduce regular differences between the analytically predicted and experimentally measured spectra at each point on the detector plane. The simulated electron density converges to that of the object as the differences are minimized. The reconstruction algorithm has been validated using simulated data produced by the EGSnrc Monte Carlo code system. We applied the imaging algorithm to a cylindrically symmetric breast tissue phantom containing multiple inhomogeneities. A preliminary ROC analysis scores greater than 0.96, which indicate that under the described simplifying conditions, this approach shows promise in identifying and localizing inhomogeneities which simulate 0.5 mm calcifications with an image voxel resolution of 0.25 cm and at a dose comparable to

  3. An iterative three-dimensional electron density imaging algorithm using uncollimated compton scattered x rays from a polyenergetic primary pencil beam.

    PubMed

    Van Uytven, Eric; Pistorius, Stephen; Gordon, Richard

    2007-01-01

    X-ray film-screen mammography is currently the gold standard for detecting breast cancer. However, one disadvantage is that it projects a three-dimensional (3D) object onto a two-dimensional (2D) image, reducing contrast between small lesions and layers of normal tissue. Another limitation is its reduced sensitivity in women with mammographically dense breasts. Computed tomography (CT) produces a 3D image yet has had a limited role in mammography due to its relatively high dose, low resolution, and low contrast. As a first step towards implementing quantitative 3D mammography, which may improve the ability to detect and specify breast tumors, we have developed an analytical technique that can use Compton scatter to obtain 3D information of an object from a single projection. Imaging material with a pencil beam of polychromatic x rays produces a characteristic scattered photon spectrum at each point on the detector plane. A comparable distribution may be calculated using a known incident x-ray energy spectrum, beam shape, and an initial estimate of the object's 3D mass attenuation and electron density. Our iterative minimization algorithm changes the initially arbitrary electron density voxel matrix to reduce regular differences between the analytically predicted and experimentally measured spectra at each point on the detector plane. The simulated electron density converges to that of the object as the differences are minimized. The reconstruction algorithm has been validated using simulated data produced by the EGSnrc Monte Carlo code system. We applied the imaging algorithm to a cylindrically symmetric breast tissue phantom containing multiple inhomogeneities. A preliminary ROC analysis scores greater than 0.96, which indicate that under the described simplifying conditions, this approach shows promise in identifying and localizing inhomogeneities which simulate 0.5 mm calcifications with an image voxel resolution of 0.25 cm and at a dose comparable to

  4. PLEIADES: a picosecond Compton scattering x-ray source for advanced backlighting and time-resolved material studies

    SciTech Connect

    Gibson, D J; Anderson, S G; Barty, C P; Betts, S M; Booth, R; Brown, W J; Crane, J K; Cross, R R; Fittinghoff, D N; Hartemann, F V; Kuba, J; Le Sage, G P; Tremaine, A M; Springer, P T; Rosenzweig, J B

    2003-10-20

    The PLEIADES (Picosecond Laser-Electron Inter-Action for the Dynamical Evaluation of Structures) facility has produced first light at 70 keV. This milestone offers a new opportunity to develop laser-driven, compact, tunable x-ray sources for critical applications such as diagnostics for the National Ignition Facility and time-resolved material studies. The electron beam was focused to 50 {micro}m rms, at 57 MeV, with 260 C of charge, a relative energy spread of 0.2%, and a normalized emittance of 5 mm mrad horizontally and 13 mm mrad vertically. The scattered 820-nm laser pulse had an energy of 180 mJ and a duration of 54 fs. Initial x-rays were captured with a cooled charge-coupled device using a Cesium Iodide scintillator; the peak photon energy was approximately 78 keV, with a total x-ray flux of 1.3 x 10{sup 6} photons/shot, and the observed angular distribution found to agree very well with three-dimensional codes. Simple K-edge radiography of a tantalum foil showed good agreement with the theoretical divergence-angle dependence of the x-ray energy. Optimization of the x-ray dose is currently underway, with the goal of reaching 10{sup 8} photons per shot and a peak brightness approaching 10{sup 20} photons/mm{sup 2}/mrad{sup 2}/s/0.1%bandwidth.

  5. The effect of detector size and energy resolution on image quality in multi-projection Compton scatter tomography.

    PubMed

    Chighvinadze, Tamar; Pistorius, Stephen

    2014-01-01

    The reconstructed electron density image quality is sensitive to the detector size and energy resolution, which contribute to the blurring and noise in the image. This work evaluates optimal values of the detector parameters for a realistic system through analytical simulations of the transverse slice of the dedicated breast CT system geometry. This study introduces a spectroscopic x-ray tomography technique which uses multiple projections to reconstruct electron density images by backprojecting scattered photons over isogonic curves. The reconstruction can be obtained using a single projection yet its quality degrades as the acquisition conditions i.e. detector size and energy resolution deviate from the ideal. The reconstruction quality becomes inconsistent throughout the image due to the data under sampling caused by the finite resolution of the detector. The extension to the multi-projection mode effectively fills-in the missing data space and improves the ability to reconstruct an object. This work demonstrates the possibility to obtain images in the presence of noise. PMID:24463390

  6. Diamond Detectors for Compton Polarimetry

    NASA Astrophysics Data System (ADS)

    Martin, J. W.; Dutta, D.; Narayan, A.; Wang, P.

    2009-12-01

    Parity-violating electron scattering experiments aim to test the standard model of particle physics through precise low-energy determinations of the weak mixing angle. These experiments require determination of the polarization of the incident electron beam to the 1% level or better. An example of this type of experiment is the Q-weak experiment, which will be conducted in Hall C at Jefferson Lab in 2010 and beyond. We are constructing a Compton polarimeter in Hall C to provide continuous monitoring of the polarization with the goal of 1% absolute polarization determination. In our Compton polarimeter, circularly polarized laser light will impinge upon the electron beam. Electrons scattered by the Compton process will be momentum-analyzed in a dipole magnet downstream of the interaction point. A diamond strip tracker will be placed further downstream of the dipole to sense the Compton-scattered electrons and determine their momenta. The design of the polarimeter, focusing on electron detection, and our progress in prototyping and constructing the diamond strip tracker, are discussed.

  7. The Compton Effect Red Shift

    NASA Astrophysics Data System (ADS)

    Kierein, John

    2004-05-01

    In 1923 (Phil Mag. 46, 897.) A. H. Compton noted that the Compton effect produces a red shift for all wavelengths when the scattered electron is free and not bound to an atom or molecule. He suggested that the red shift in the visible spectrum at the limb of the sun is larger than that at the center due to the Compton effect from the greater number of free electrons in the sun's atmosphere along the line of sight. Kierein and Sharp (1968, Solar Physics 3, 450) quantified this and showed a good correlation of red shift observations with the variation in the number of these electrons along the line of sight from center to limb and suggested that the quasar red shift and cosmological red shift could be similarly explained. Grote Reber mapped and measured the background hectometric radiation and found it to be unexpectedly bright. In 1968 (J. Franklin Inst. 285,1), while describing these measurements and maps he explained this brightness as being due to the Compton effect causing the cosmological red shift and accelerating intergalactic electrons. The resulting universe is static. The predicted red shift from the Compton effect deviates from Hubble's law only at large red shifts.

  8. Polarization Measurements with Compton Telescopes

    NASA Astrophysics Data System (ADS)

    Akyuz, A.; O'Neill, T. J.; Bhattacharya, D.; Dixon, D. D.; Tumer, T. O.; White, R. S.; Zych, A. D.

    1994-12-01

    The response of the Tracking and Imaging Gamma-Ray Experiment (TIGRE) instrument to polarized celestial gamma rays above 300 keV is presented. TIGRE uses multilayers of silicon strip detectors both as a gamma-ray converter and to track Compton recoil electrons and positron-electron pairs up to 100 MeV. For Compton events, the direction and energy of the Compton scattered gamma ray are measured with arrays of small CsI(Tl)-photodiode detectors. A small balloon prototype instrument is being constructed that has a high absolute detection efficiency of 10% and a sensitivity of 100 milliCrabs for an exposure of 12 hours. The prototype's sensitivity to polarized gamma radiation has been calculated with the MCNP detector simulation code which was modified to include the polarization dependence of the Klein-Nishina formula. Polarized events and unpolarized source events with background are combined to simulate an observation of the Crab Nebula and pulsar. TIGRE's polarization modulation factor varies from 0.17 to 0.42 depending on the energy and Compton scatter angle cuts that are used. With 12 hours of observation on the Crab, polarized gamma radiation can be detected down to the level of about 10%. Potential celestial sources of polarized gamma-ray emission will be discussed.

  9. Investigating the Compton Effect with a Spreadsheet.

    ERIC Educational Resources Information Center

    Kinderman, Jesusa Valdez

    1992-01-01

    Describes a computer simulation of the Compton effect designed to lead students to discover (1) the relationship of the electron's final kinetic energy to its angle of scattering and (2) the relationship between the scattering angles of the outgoing electron and photon. (MDH)

  10. A confocal three-dimensional micro X-ray scattering technology based on Rayleigh to Compton ratio for identifying materials with similar density and different weight percentages of low-Z elements

    NASA Astrophysics Data System (ADS)

    Li, Fangzuo; Liu, Zhiguo; Sun, Tianxi; Yang, Chaolin; Sun, Xuepeng; Sun, Weiyuan; He, Jialin; Ding, Xunliang

    2015-07-01

    A point-by-point Rayleigh to Compton scattering ratio (R/C) imaging for two polymer materials with similar density and different weight percentages of low-Z elements was carried out by using the confocal three-dimensional (3D) micro X-ray scatter tomographic technology based on polycapillary X-ray optics. This confocal 3D micro X-ray scatter tomographic technique was based on the confocal configuration of a polycapillary focusing X-ray lens (PFXRL) in the excitation channel and a polycapillary parallel X-ray lens (PPXRL) in the detection channel, which let only the X-rays scattered from the confocal micro-volume overlapped by the input focal spot of the PPXRL and the output focal spot of the PFXRL be detected by the detector. The main scope of this study was using the confocal 3D micro X-ray scattering tomography based on the R/C ratio to characterize and identify materials with nearly equal low density and different weight percentages of low-Z elements, as other radiological techniques are difficult to discriminate them for their very close attenuation coefficients μ . A mapping of R/C ratios for two thermoplastic polymer materials was obtained, which provided the spatially resolved distribution of their effective atom numbers, and their differences were accordingly presented. This confocal 3D micro X-ray scatter tomographic technique has potential applications in fields such as material identification, dosimetry, medical imaging, carbonation cancer, and so on.

  11. SPEIR: A Ge Compton Camera

    SciTech Connect

    Mihailescu, L; Vetter, K M; Burks, M T; Hull, E L; Craig, W W

    2004-02-11

    The SPEctroscopic Imager for {gamma}-Rays (SPEIR) is a new concept of a compact {gamma}-ray imaging system of high efficiency and spectroscopic resolution with a 4-{pi} field-of-view. The system behind this concept employs double-sided segmented planar Ge detectors accompanied by the use of list-mode photon reconstruction methods to create a sensitive, compact Compton scatter camera.

  12. The Compton polarimeter for SLC

    SciTech Connect

    Fero, M.J.; The SLD Collaboration

    1992-12-01

    We report on the use of a Compton scattering based polarimeter to measure beam polarization near the e{sup +}e{sub -} interaction point at the SLAC Linear Collider (SLC). Measurement of the beam polarization to a statistical precision of {delta}P/P={plus_minus}3% requires approximately three minutes under normal conditions. An average beam polarization of 22.4{plus_minus}0.7%(syst.) was measured over the course of the 1992 polarized beam run.

  13. The Compton polarimeter for SLC

    SciTech Connect

    Fero, M.J. )

    1992-12-01

    We report on the use of a Compton scattering based polarimeter to measure beam polarization near the e[sup +]e[sub -] interaction point at the SLAC Linear Collider (SLC). Measurement of the beam polarization to a statistical precision of [delta]P/P=[plus minus]3% requires approximately three minutes under normal conditions. An average beam polarization of 22.4[plus minus]0.7%(syst.) was measured over the course of the 1992 polarized beam run.

  14. Compton Sources of Electromagnetic Radiation

    SciTech Connect

    Geoffrey Krafft,Gerd Priebe

    2011-01-01

    When a relativistic electron beam interacts with a high-field laser beam, intense and highly collimated electromagnetic radiation will be generated through Compton scattering. Through relativistic upshifting and the relativistic Doppler effect, highly energetic polarized photons are radiated along the electron beam motion when the electrons interact with the laser light. For example, X-ray radiation can be obtained when optical lasers are scattered from electrons of tens-of-MeV beam energy. Because of the desirable properties of the radiation produced, many groups around the world have been designing, building, and utilizing Compton sources for a wide variety of purposes. In this review article, we discuss the generation and properties of the scattered radiation, the types of Compton source devices that have been constructed to date, and the prospects of radiation sources of this general type. Due to the possibilities of producing hard electromagnetic radiation in a device that is small compared to the alternative storage ring sources, it is foreseen that large numbers of such sources may be constructed in the future.

  15. Compton polarimetry revisited

    NASA Astrophysics Data System (ADS)

    Bernard, D.

    2015-11-01

    We compute the average polarisation asymmetry from the Klein-Nishina differential cross-section on free electrons at rest. As expected from the expression for the asymmetry, the average asymmetry is found to decrease like the inverse of the incident photon energy asymptotically at high energy. We then compute a simple estimator of the polarisation fraction that makes optimal use of all the kinematic information present in an event final state, by the use of "moments" method, and we compare its statistical power to that of a simple fit of the azimuthal distribution. In contrast to polarimetry with pair creation, for which we obtained an improvement by a factor of larger than two in a previous work, here for Compton scattering the improvement is only of 10-20%.

  16. Spin momentum density of Nd using Compton spectroscopy

    SciTech Connect

    Sahariya, Jagrati; Dashora, Alpa; Mund, H. S.; Ahuja, B. L.; Tiwari, Shailja; Itou, M.; Sakurai, Y.

    2013-02-05

    Spin momentum density of Nd has been measured at 6K temperature using magnetic Compton scattering. The individual contribution of different electronic states, in the formation of total spin moment, is deduced from the analysis of magnetic Compton profile. The electron-specific spin moments deduced from the experimental Compton data are compared with the theoretical results obtained from full potential linearized augmented plane wave method and are found to be in good agreement.

  17. Monitoring the distribution of prompt gamma rays in boron neutron capture therapy using a multiple-scattering Compton camera: A Monte Carlo simulation study

    NASA Astrophysics Data System (ADS)

    Lee, Taewoong; Lee, Hyounggun; Lee, Wonho

    2015-10-01

    This study evaluated the use of Compton imaging technology to monitor prompt gamma rays emitted by 10B in boron neutron capture therapy (BNCT) applied to a computerized human phantom. The Monte Carlo method, including particle-tracking techniques, was used for simulation. The distribution of prompt gamma rays emitted by the phantom during irradiation with neutron beams is closely associated with the distribution of the boron in the phantom. Maximum likelihood expectation maximization (MLEM) method was applied to the information obtained from the detected prompt gamma rays to reconstruct the distribution of the tumor including the boron uptake regions (BURs). The reconstructed Compton images of the prompt gamma rays were combined with the cross-sectional images of the human phantom. Quantitative analysis of the intensity curves showed that all combined images matched the predetermined conditions of the simulation. The tumors including the BURs were distinguishable if they were more than 2 cm apart.

  18. Bayesian Event Reconstruction for Advanced Compton Telescopes

    NASA Astrophysics Data System (ADS)

    Zoglauer, A.; ACT

    2004-12-01

    Measuring gamma rays via Compton scattering in a space environment is a challenging task: weak source signals have to be extracted from dominating background, which mainly originates from cosmic rays (prompt interactions as well as delayed decays) and earth albedo photons. The approach of Advanced Compton Telescopes (ACT) to overcome this problem is to measure more parameters of the events (several Compton interactions, the recoil electron direction, etc.) with a higher accuracy than previous Compton telescopes like COMPTEL. Still, this leaves the event reconstruction with three main tasks: Find the correct sequence of interactions, identify background and suppress incompletely absorbed events. The most promising approach to accomplish those tasks is based on Bayesian statistics: The Compton interactions are parameterized in an eight-dimensional data space, which contains the interaction information of the Compton sequence. For each data space cell the probability that the corresponding interaction sequence is those of a correctly ordered, completely absorbed source photon can be determined by detailed simulations. The result is an absolute quality factor for each event, based on which source events can be distinguished from background and incompletely absorbed photons. We will report on the performance of the algorithm for a typical advanced Compton telescope design.

  19. Virtual Compton Scattering in the Resonance Region Up to the Deep Inelastic Region at Backward Angles and Momentum Transfer Squared of Q**2=1.0 GeV**2

    SciTech Connect

    Geraud Laveissiere; Natalie Degrande; Stephanie Jaminion; Christophe Jutier; Luminita Todor; Rachele Di Salvo; L. Van Hoorebeke; et. al.

    2004-06-01

    We have made the first measurements of the virtual Compton scattering process via the ep {yields} ep{gamma} exclusive reaction at Q{sup 2} = 1 GeV{sup 2} in the nucleon resonance region. The cross section is obtained at center of mass (CM) backward angle, in a range of total ({gamma}*p) CM energy W from the proton mass up to W = 1.91 GeV. The data show resonant structures in the first and second resonance regions, and are well reproduced at higher W by the Bethe-Heitler+Born cross section, including t-channel {pi}{sup 0}-exchange. At high W, our data, together with existing real photon data, show a striking Q{sup 2} independence. Our measurement of the ratio of H(e,e{prime}p){gamma} to H(e,e{prime}p){pi}{sup 0} cross sections is presented and compared to model predictions.

  20. GRAPE: A Compton Polarimetry Experiment

    NASA Astrophysics Data System (ADS)

    Connor, Taylor; Bloser, Peter; Legere, Jason; McConnell, Mark; Ryan, James

    2009-10-01

    We review the design, calibration and data analysis of the Gamma Ray Polarimetry Experiment (GRAPE), a Compton polarimeter device for measuring the polarization of photons in the 50-500 keV energy range. In Compton scattering, X-ray and gamma-ray photons tend to scatter at right angles with respect to their polarization vector. We exploit this fact to measure the polarization of the incident radiation by looking at the azimuthal distribution of the scattered photons. This distribution gives us a measure of both the level of polarization and the orientation of the polarization vector. These measurements will allow us to probe the particle acceleration regions of astronomical sources. GRAPE will be flown in the fall of 2011 on as a high altitude balloon payload. The primary target of that flight will be the Crab Nebula, with the Sun (solar flares) and Cygnus X-1 as secondary targets. Our observations of the Crab will be compared to the findings of the INTErnational Gamma-Ray Astrophysics Laboratory (INTEGRAL), which provided constraints on the location of the particle acceleration region within the Crab Nenbula. Following the initial flight in 2011, we hope to fly GRAPE on a long duration balloon flight from Antarctica to study gamma-ray bursts.

  1. Design and optimization of a highly efficient optical multipass system for γ-ray beam production from electron laser beam Compton scattering

    NASA Astrophysics Data System (ADS)

    Dupraz, K.; Cassou, K.; Delerue, N.; Fichot, P.; Martens, A.; Stocchi, A.; Variola, A.; Zomer, F.; Courjaud, A.; Mottay, E.; Druon, F.; Gatti, G.; Ghigo, A.; Hovsepian, T.; Riou, J. Y.; Wang, F.; Mueller, A. C.; Palumbo, L.; Serafini, L.; Tomassini, P.

    2014-03-01

    A new kind of nonresonant optical recirculator, dedicated to the production of γ rays by means of Compton backscattering, is described. This novel instrument, inspired by optical multipass systems, has its design focused on high flux and very small spectral bandwidth of the γ-ray beam. It has been developed to fulfill the project specifications of the European Extreme Light Infrastructure "Nuclear Pillar," i.e., the Gamma Beam System. Our system allows a single high power laser pulse to recirculate 32 times synchronized on the radio frequency driving accelerating cavities for the electron beam. Namely, the polarization of the laser beam and crossing angle between laser and electrons are preserved all along the 32 passes. Moreover, optical aberrations are kept at a negligible level. The general tools developed for designing, optimizing, and aligning the system are described. A detailed simulation demonstrates the high efficiency of the device.

  2. Compton Gamma Ray Observatory Guest Investigator Program

    NASA Technical Reports Server (NTRS)

    Lingenfelter, Richard E.

    1997-01-01

    This paper presents a final report for the Compton Gamma Ray Observatory Guest Investigator Program from 06/01/91-07/31/97. The topics include: 1) Solar Flare Neutron Spectra and Accelerated Ions; 2) Gamma Ray Lines From The Orion Complex; 3) Implications of Nuclear Line Emission From The Orion Complex; 4) Possible Sites of Nuclear Line Emission From Massive OB Associations; 5) Gamma-Ray Burst Repitition and BATSE Position Uncertainties; 6) Effects of Compton Scattering on BATSE Gamma-Ray Burst Spectra; and 7) Selection Biases on the Spectral and Temporal Distribution of Gamma Ray Bursts.

  3. Resonant Compton Physics for Magnetar Astrophysics

    NASA Astrophysics Data System (ADS)

    Ickes, Jesse; Gonthier, Peter L.; Eiles, Matthew; Baring, Matthew G.

    2016-01-01

    Various telescopes including RXTE, INTEGRAL, Suzaku, and Fermi have detected steady non-thermal X-ray emission in the 10 - 200 keV band from strongly magnetic neutron stars known as magnetars. Magnetic inverse Compton scattering is believed to be the leading candidate for the production of this intense X-ray radiation. Scattering at ultra-relativistic energies leads to attractive simplifications in the analytics of the magnetic Compton cross section. We have recently addressed such a case by developing compact analytic expressions using correct spin-dependent widths acquired through the implementation of Sokolov & Ternov basis states, focusing specifically on ground-state-ground-state scattering. Compton scattering in magnetar magnetospheres can cool electrons down to mildly relativistic energies. Moreover, soft gamma-ray flaring in magnetars may involve strong Comptonization in expanding clouds of mildly relativistic pairs. Such environs necessitate the development of more general magnetic scattering cross sections, in which the incoming photons acquire substantial incident angles relative to the field in the rest frame of the electron leading to arbitrary Landau excitations of the intermediate and final states. Due to the rapid transitions of the excited-state to the ground-state, the initial electron is still assumed to be in the ground state. The cross sections treat the plethora of harmonic resonances associated with various cyclotron transitions between Landau states. Polarization and spin dependence of the cross section for the four scattering modes is compared to the cross section obtained with spin-averaged widths. We present numerical results to show the comparisons to highlight the role of the spin-dependent widths of the resonances. The findings presented here will have applications to various neutron star problems, including computation of Eddington luminosities and polarization mode-switching rates in transient magnetar fireballs.

  4. Excited nucleon as a van der Waals system of partons

    SciTech Connect

    Jenkovszky, L. L.; Muskeyev, A. O. Yezhov, S. N.

    2012-06-15

    Saturation in deep inelastic scattering (DIS) and deeply virtual Compton scattering (DVCS) is associated with a phase transition between the partonic gas, typical of moderate x and Q{sup 2}, and partonic fluid appearing at increasing Q{sup 2} and decreasing Bjorken x. We suggest the van der Waals equation of state to describe properly this phase transition.

  5. Portable compton gamma-ray detection system

    DOEpatents

    Rowland, Mark S.; Oldaker, Mark E.

    2008-03-04

    A Compton scattered gamma-ray detector system. The system comprises a gamma-ray spectrometer and an annular array of individual scintillators. The scintillators are positioned so that they are arrayed around the gamma-ray spectrometer. The annular array of individual scintillators includes a first scintillator. A radiation shield is positioned around the first scintillator. A multi-channel analyzer is operatively connected to the gamma-ray spectrometer and the annular array of individual scintillators.

  6. Quasilinear theory of terahertz free-electron lasers based on Compton scattering of incoherent pump wave by intense relativistic electron beam

    NASA Astrophysics Data System (ADS)

    Ginzburg, N. S.; Kocharovskaya, E. R.

    2016-08-01

    The use of incoherent broadband pump radiation for improving the electron efficiency in the free-electron lasers (FEL) based on stimulated backscattering is considered. On the basis of a quasilinear approach, it is shown that the efficiency increases in proportion to the width of the pump spectrum. The effect is owing to a broadening of the spectrum of synchronous combination waves and realization of a mechanism of stochastic particle deceleration. The injection of a monochromatic seed signal in a single pass FEL amplifier or the implementation of a selective high-Q resonator in an FEL oscillator makes the high-frequency scattered radiation be monochromatic in spite of an incoherent pumping. In the regime of stochastic particle deceleration, the efficiency only slightly depends on the spread of the beam parameters, which is beneficial for a terahertz FEL powered by intense relativistic electron beams.

  7. The Compton generator revisited

    NASA Astrophysics Data System (ADS)

    Siboni, S.

    2014-09-01

    The Compton generator, introduced in 1913 by the US physicist A H Compton as a relatively simple device to detect the Earth's rotation with respect to the distant stars, is analyzed and discussed in a general perspective. The paper introduces a generalized definition of the generator, emphasizing the special features of the original apparatus, and provides a suggestive interpretation of the way the device works. To this end, an intriguing electromagnetic analogy is developed, which turns out to be particularly useful in simplifying the calculations. Besides the more extensive description of the Compton generator in itself, the combined use of concepts and methods coming from different fields of physics, such as particle dynamics in moving references frames, continuum mechanics and electromagnetism, may be of interest to both teachers and graduate students.

  8. The Compton effect: Transition to quantum mechanics

    NASA Astrophysics Data System (ADS)

    Stuewer, R. H.

    2000-11-01

    The discovery of the Compton effect at the end of 1922 was a decisive event in the transition to the new quantum mechanics of 1925-1926 because it stimulated physicists to examine anew the fundamental problem of the interaction between radiation and matter. I first discuss Albert Einstein's light-quantum hypothesis of 1905 and why physicists greeted it with extreme skepticism, despite Robert A. Millikan's confirmation of Einstein's equation of the photoelectric effect in 1915. I then follow in some detail the experimental and theoretical research program that Arthur Holly Compton pursued between 1916 and 1922 at the University of Minnesota, the Westinghouse Lamp Company, the Cavendish Laboratory, and Washington University that culminated in his discovery of the Compton effect. Surprisingly, Compton was not influenced directly by Einstein's light-quantum hypothesis, in contrast to Peter Debye and H.A. Kramers, who discovered the quantum theory of scattering independently. I close by discussing the most significant response to that discovery, the Bohr-Kramers-Slater theory of 1924, its experimental refutation, and its influence on the emerging new quantum mechanics.

  9. Relativistic dynamics of the Compton diffusion on a bound electron

    NASA Astrophysics Data System (ADS)

    Al Saleh, Salwa

    2016-05-01

    A covariant relativistic formalism for the electron-photon and nuclear dynamics is summarised making more accurate predictions in agreement with experiments for Compton scattering in shells with large electron binding energy. An exact solution for the Dirac equation for an electron in the nuclear Coulomb field is obtained, in order to write the relativistic dynamics for this QED process. This is a preparation for the calculation of the relativistic cross-section for Compton scattering on bound electrons, as a precision test for QED.

  10. Compton Profile Study of Intermetallic Ti{sub 3}Al

    SciTech Connect

    Vyas, V.; Sharma, G.; Mishra, M. C.; Sharma, B. K.; Joshi, K. B.

    2011-10-20

    The Compton scattering measurement on intermetallic alloy Ti{sub 3}Al is reported in this work. The measurement is made using 59.54 keV gamma-rays from Am{sup 241} source. Theoretical calculation of Compton profile is also performed employing CRYSTAL code within the framework of density functional theory to compare with the measurement. The theoretical profile of the alloy is also synthesized following the superposition model taking the published Compton profiles of elemental solids from the APW method. The experimental study of charge transfer in the alloys has also been done by performing the experimental Compton profile measurements on Ti and Al following the superposition model and charge transfer from Al to Ti is clearly seen on the alloy formation.

  11. Compton-edge-based energy calibration of double-sided silicon strip detectors in Compton camera

    NASA Astrophysics Data System (ADS)

    Seo, Hee; Park, Jin Hyung; Kim, Chan Hyeong; Lee, Ju Hahn; Lee, Chun Sik; Sung Lee, Jae

    2011-05-01

    Accurate energy calibration of double-sided silicon strip detectors (DSSDs) is very important, but challenging for high-energy photons. In the present study, the calibration was improved by considering the Compton edge additionally to the existing low-energy calibration points. The result, indeed, was very encouraging. The energy-calibration errors were dramatically reduced, from, on average, 15.5% and 16.9% to 0.47% and 0.31% for the 356 (133Ba) and 662 keV (137Cs) peaks, respectively. The imaging resolution of a double-scattering-type Compton camera using DSSDs as the scatterer detectors, for a 22Na point-like source, also was improved, by ˜9%.

  12. Physics updates from HERMES

    SciTech Connect

    Murray, Morgan J.; Collaboration: HERMES Collaboration

    2013-04-15

    The HERMES collaboration presents two sets of recent results: the first related to an extraction of the g{sub 2} nucleon structure function determined for DIS on a polarised target and the second related to the measurement of asymmetries related to the deeply virtual Compton scattering process that can be used to discover information on generalised parton distributions and hence nucleon structure.

  13. Physics updates from HERMES

    NASA Astrophysics Data System (ADS)

    Murray, Morgan J.; Hermes Collaboration

    2013-04-01

    The HERMES collaboration presents two sets of recent results: the first related to an extraction of the g2 nucleon structure function determined for DIS on a polarised target and the second related to the measurement of asymmetries related to the deeply virtual Compton scattering process that can be used to discover information on generalised parton distributions and hence nucleon structure.

  14. Dvcs at Hermes

    NASA Astrophysics Data System (ADS)

    Murray, M.

    2014-01-01

    This talk explores the impact that the Hermes experiment has had regarding knowledge of the Deeply Virtual Compton Scattering process. We discuss the various measurements that HERMES has contributed to the library of DVCS knowledge [1-3], with focus in particular on the recent high-precision beam spin and charge asymmetries [4].

  15. G. E. M. Jauncey and the Compton Effect

    NASA Astrophysics Data System (ADS)

    Jenkin, John

    In late 1922 Arthur Holly Compton (1892-1962) discovered that an X-ray quantum of radiation undergoes a discrete change in wavelength when it experiences a billiard-ball collision with a single atomic electron, a phenomenon that became known as the Compton effect and for which he shared the Nobel Prize in Physics for 1927. But for more than five years before he made his discovery, Compton had analyzed X-ray scattering in terms of classical electrodynamics. I suggest that his colleague at Washington University in St. Louis, G. E. M. Jauncey (1888-1947), helped materially to persuade him to embrace the quantum interpretation of his X-ray scattering experiments.

  16. The cross section for double Compton scattering

    NASA Technical Reports Server (NTRS)

    Gould, R. J.

    1984-01-01

    Employing elementary methods in nonrelativistic quantum electrodynamics, the cross section for gamma sub 0 + e yields e + gamma + gamma is computed for arbitrary energy in the spectrum of the outgoing photons. The final result is given, differential in the energy of one of these photons, for the case where the incident photon is unpolarized and has energy E sub 0 much less than mc-squared, a polarization sum and angular integration being performed for the final-state photons. The cross section has a simple algebraic form resulting from contributions from the sum of squared direct and exchange amplitudes; interference terms from these amplitudes do not contribute to the angular-integrated cross section.

  17. Gravitational Compton Scattering from the Worldline Formalism

    NASA Astrophysics Data System (ADS)

    Ahmadiniaz, Naser; Corradini, Olindo; Dávila, José Manuel; Schubert, Christian

    2016-07-01

    We report on an ongoing study of photon amplitudes, graviton amplitudes and mixed photon-graviton amplitudes at tree-level using the worldline formalism. We explicitly recalculate the amplitude with one photon and one graviton coupled to a scalar propagator, relevant for graviton photoproduction. We comment on the factorization properties of this amplitude, and outline a generalization to similar processes involving more gravitons.

  18. Spectra of clinical CT scanners using a portable Compton spectrometer

    SciTech Connect

    Duisterwinkel, H. A.; Abbema, J. K. van; Kawachimaru, R.; Paganini, L.; Graaf, E. R. van der; Brandenburg, S.; Goethem, M. J. van

    2015-04-15

    Purpose: Spectral information of the output of x-ray tubes in (dual source) computer tomography (CT) scanners can be used to improve the conversion of CT numbers to proton stopping power and can be used to advantage in CT scanner quality assurance. The purpose of this study is to design, validate, and apply a compact portable Compton spectrometer that was constructed to accurately measure x-ray spectra of CT scanners. Methods: In the design of the Compton spectrometer, the shielding materials were carefully chosen and positioned to reduce background by x-ray fluorescence from the materials used. The spectrum of Compton scattered x-rays alters from the original source spectrum due to various physical processes. Reconstruction of the original x-ray spectrum from the Compton scattered spectrum is based on Monte Carlo simulations of the processes involved. This reconstruction is validated by comparing directly and indirectly measured spectra of a mobile x-ray tube. The Compton spectrometer is assessed in a clinical setting by measuring x-ray spectra at various tube voltages of three different medical CT scanner x-ray tubes. Results: The directly and indirectly measured spectra are in good agreement (their ratio being 0.99) thereby validating the reconstruction method. The measured spectra of the medical CT scanners are consistent with theoretical spectra and spectra obtained from the x-ray tube manufacturer. Conclusions: A Compton spectrometer has been successfully designed, constructed, validated, and applied in the measurement of x-ray spectra of CT scanners. These measurements show that our compact Compton spectrometer can be rapidly set-up using the alignment lasers of the CT scanner, thereby enabling its use in commissioning, troubleshooting, and, e.g., annual performance check-ups of CT scanners.

  19. The development of a Compton lung densitometer

    SciTech Connect

    Loo, B.W.; Goulding, F.S.; Madden, N.W.; Simon, D.S.

    1988-11-01

    A field instrument is being developed for the non-invasive determination of absolute lung density using unique Compton backscattering techniques. A system consisting of a monoenergetic gamma-ray beam and a shielded high resolution high-purity-germanium (HPGe) detector in a close-coupled geometry is designed to minimize errors due to multiple scattering and uncontrollable attenuation in the chestwall. Results of studies on system performance with phantoms, the optimization of detectors, and the fabrication of a practical gamma-ray source are presented. 3 refs., 6 figs., 2 tabs.

  20. High flux, narrow bandwidth compton light sources via extended laser-electron interactions

    SciTech Connect

    Barty, V P

    2015-01-13

    New configurations of lasers and electron beams efficiently and robustly produce high flux beams of bright, tunable, polarized quasi-monoenergetic x-rays and gamma-rays via laser-Compton scattering. Specifically, the use of long-duration, pulsed lasers and closely-spaced, low-charge and low emittance bunches of electron beams increase the spectral flux of the Compton-scattered x-rays and gamma rays, increase efficiency of the laser-electron interaction and significantly reduce the overall complexity of Compton based light sources.

  1. Method and apparatus for measuring lung density by Compton backscattering

    DOEpatents

    Loo, B.W.; Goulding, F.S.

    1988-03-11

    The density of the lung of a patient suffering from pulmonary edema is monitored by irradiating the lung by a single collimated beam of monochromatic photons and measuring the energies of photons compton back-scattered from the lung by a single high-resolution, high-purity germanium detector. A compact system geometry and a unique data extraction scheme are utilized to minimize systematic errors due to the presence of the chestwall and multiple scattering. 11 figs., 1 tab.

  2. Deeply virtual and exclusive production of the omega meson

    SciTech Connect

    M. Garcon; L. Morand; D. Dore; J.-M. Laget; S. Morrow; F. Sabatie

    2005-04-01

    Exclusive {omega} electroproduction off the proton was measured at the highest possible four-momentum transfer with the (close to) 6 GeV beam now available at CEBAF. Cross sections are presented, together with an analysis of the {omega} spin density matrix elements. Indications are that {pi}{sup 0} exchange in the t-channel (or rather the exchange of the corresponding saturating Regge trajectory) seems to dominate the process {gamma}*p {yields} {omega}p, even for photon virtuality Q{sup 2} as large as 5 GeV{sup 2}. Contributions of the handbag type, related to Generalized Parton Distributions in the nucleon, are therefore difficult to extract from this particular process.

  3. Deeply virtual and exclusive electroproduction of omega mesons

    SciTech Connect

    Morand, L; Et. Al.

    2005-04-01

    The exclusive omega electroproduction off the proton was studied in a large kinematical domain above the nucleon resonance region and for the highest possible photon virtuality (Q{sup 2}) with the 5.75 GeV beam at CEBAF and the CLAS spectrometer. Cross sections were measured up to large values of the four-momentum transfer (-t < 2.7 GeV{sup 2}) to the proton. The contributions of the interference terms sigma{sub TT} and sigma{sub TL} to the cross sections, as well as an analysis of the omega spin density matrix, indicate that helicity is not conserved in this process. The t-channel pi{sup 0} exchange, or more generally the exchange of the associated Regge trajectory, seems to dominate the reaction {gamma}* p {yields} omega p, even for Q{sup 2} as large as 5 GeV{sub 2}. Contributions of handbag diagrams, related to Generalized Parton Distributions in the nucleon, are therefore difficult to extract for this process. Remarkably, the high-t behavior of the cross sections is nearly Q{sup 2}-independent, which may be interpreted as a coupling of the photon to a point-like object in this kinematical limit.

  4. A nonlinear plasma retroreflector for single pulse Compton backscattering

    NASA Astrophysics Data System (ADS)

    Palastro, J. P.; Kaganovich, D.; Gordon, D.; Hafizi, B.; Penano, J.; Helle, M.; Ting, A.

    2014-10-01

    A long laser pulse focused onto the edge of a gas jet nozzle launches a shock wave. The shock wave and gas jet flow collide forming a density spike. The leading edge of an incident ultrashort laser pulse ionizes the gas, while the bulk undergoes a nonlinear Poynting flux reversal from the ionized spike. The resulting counterpropagating field can Compton backscatter from electrons accelerated in the ultrashort pulse's wakefield, upshifting the frequency. We examine the reversal mechanism and properties of the counterpropagating field to optimize the Compton scattered radiation.

  5. The scanning Compton polarimeter for the SLD experiment

    SciTech Connect

    Woods, M.; SLD Collaboration

    1996-10-01

    For the 1994/95 run of the SLD experiment at SLAC, a Compton polarimeter measured the luminosity-weighted electron beam polarization to be (77.2 {+-} 0.5)%. This excellent accuracy is achieved by measuring the rate asymmetry of Compton-scattered electrons near the kinematic endpoint. The polarimeter takes data continuously while the electron and positron beams are in collision and achieves a statistical precision of better than 1% in a three minute run. To calibrate the polarimeter and demonstrate its accuracy, many scans are frequently done. These include scans of the laser polarization, the detector position with respect to the kinematic edge, and the laser power.

  6. Scattered X-ray beam nondestructive testing

    NASA Astrophysics Data System (ADS)

    Harding, G.; Kosanetzky, J.

    1989-08-01

    X-ray scatter interactions generally dominate the linear attenuation coefficient at the photon energies typical of medical and industrial radiography. Specific advantages of X-ray scatter imaging, including a flexible choice of measurement geometry, direct 3D-imaging capability (tomography) and improved information for material characterization, are illustrated with results from Compton and coherent scatter devices. Applications of a Compton backscatter scanner (ComScan) in the aerospace industry and coherent scatter imaging in security screening are briefly considered.

  7. External inverse-Compton Emission from Blazar Jets

    SciTech Connect

    Carson, Jennifer E.; Chiang, James; /SLAC

    2007-09-25

    According to leptonic models for the high-energy emission from blazars, relativistic electrons in the inner jets inverse-Compton scatter photons from a variety of sources. Seed photons are certainly introduced via the synchrotron process from the electrons themselves, but external sources of seed photons may also be present. In this paper, we present detailed derivations of the equations describing external inverse-Compton scattering from two sources of seed photons: direct emission from the accretion disk, and accretion disk photons that have scattered off the broad line region. For each source, we derive the seed photon spectrum incident on the jet, the single electron energy loss rate, and the emitted photon spectrum.

  8. A Compton profile representation for some second period elements

    NASA Astrophysics Data System (ADS)

    Harding, Geoffrey; Olesinski, Stephan

    2011-09-01

    Compton profiles for the elements C, N and O, which are important both in medical science and security screening, are represented here as weighted sums of three Gaussians. Simple scaling relationships describe the dependence on atomic number ( Z) of the amplitudes and standard deviations of the component Gaussians, which are identified with the Compton profiles of the 1s, 2s and 2p orbitals. This representation of the Compton profile agrees with tabulated values for C, N and O to a rms deviation of the order of 1% of the mean profile amplitude over the momentum range 0≤ q≤4, where q is expressed in units of the hydrogen ground state momentum. This representation allows a "mean atomic number" for mixtures and compounds dominated by second period elements to be assigned on the basis of experimental measurements of the Doppler broadening of back-scattered X-ray K characteristic lines. Processed spectra of water and ethanol from a Compton spectrometer equipped with a room-temperature semiconductor detector are compared with the Compton profiles synthesized as suggested here, and a satisfactory agreement between the measured and theoretical mean atomic numbers and the profile shapes is found.

  9. Results of a Si/Cdte Compton Telescope

    SciTech Connect

    Oonuki, Kousuke; Tanaka, Takaaki; Watanabe, Shin; Takeda, Shin'ichiro; Nakazawa, Kazuhiro; Mitani, Takefumi; Takahashi, Tadayuki; Tajima, Hiroyasu; Fukazawa, Yasushi; Nomachi, Masaharu; /Sagamihara, Inst. Space Astron. Sci. /Tokyo U. /SLAC /Hiroshima U. /Osaka U.

    2005-09-23

    We have been developing a semiconductor Compton telescope to explore the universe in the energy band from several tens of keV to a few MeV. We use a Si strip and CdTe pixel detector for the Compton telescope to cover an energy range from 60 keV. For energies above several hundred keV, the higher efficiency of CdTe semiconductor in comparison with Si is expected to play an important role as an absorber and a scatterer. In order to demonstrate the spectral and imaging capability of a CdTe-based Compton Telescope, we have developed a Compton telescope consisting of a stack of CdTe pixel detectors as a small scale prototype. With this prototype, we succeeded in reconstructing images and spectra by solving the Compton equation from 122 keV to 662 keV. The energy resolution (FWHM) of reconstructed spectra is 7.3 keV at 511 keV and 3.1 keV at 122 keV, respectively. The angular resolution obtained at 511 keV is measured to be 12.2{sup o}(FWHM).

  10. Compton backscattered collmated X-ray source

    DOEpatents

    Ruth, Ronald D.; Huang, Zhirong

    2000-01-01

    A high-intensity, inexpensive and collimated x-ray source for applications such as x-ray lithography is disclosed. An intense pulse from a high power laser, stored in a high-finesse resonator, repetitively collides nearly head-on with and Compton backscatters off a bunched electron beam, having relatively low energy and circulating in a compact storage ring. Both the laser and the electron beams are tightly focused and matched at the interaction region inside the optical resonator. The laser-electron interaction not only gives rise to x-rays at the desired wavelength, but also cools and stabilizes the electrons against intrabeam scattering and Coulomb repulsion with each other in the storage ring. This cooling provides a compact, intense bunch of electrons suitable for many applications. In particular, a sufficient amount of x-rays can be generated by this device to make it an excellent and flexible Compton backscattered x-ray (CBX) source for high throughput x-ray lithography and many other applications.

  11. Compton backscattered collimated x-ray source

    DOEpatents

    Ruth, R.D.; Huang, Z.

    1998-10-20

    A high-intensity, inexpensive and collimated x-ray source is disclosed for applications such as x-ray lithography is disclosed. An intense pulse from a high power laser, stored in a high-finesse resonator, repetitively collides nearly head-on with and Compton backscatters off a bunched electron beam, having relatively low energy and circulating in a compact storage ring. Both the laser and the electron beams are tightly focused and matched at the interaction region inside the optical resonator. The laser-electron interaction not only gives rise to x-rays at the desired wavelength, but also cools and stabilizes the electrons against intrabeam scattering and Coulomb repulsion with each other in the storage ring. This cooling provides a compact, intense bunch of electrons suitable for many applications. In particular, a sufficient amount of x-rays can be generated by this device to make it an excellent and flexible Compton backscattered x-ray (CBX) source for high throughput x-ray lithography and many other applications. 4 figs.

  12. Compton backscattered collimated x-ray source

    DOEpatents

    Ruth, Ronald D.; Huang, Zhirong

    1998-01-01

    A high-intensity, inexpensive and collimated x-ray source for applications such as x-ray lithography is disclosed. An intense pulse from a high power laser, stored in a high-finesse resonator, repetitively collides nearly head-on with and Compton backscatters off a bunched electron beam, having relatively low energy and circulating in a compact storage ring. Both the laser and the electron beams are tightly focused and matched at the interaction region inside the optical resonator. The laser-electron interaction not only gives rise to x-rays at the desired wavelength, but also cools and stabilizes the electrons against intrabeam scattering and Coulomb repulsion with each other in the storage ring. This cooling provides a compact, intense bunch of electrons suitable for many applications. In particular, a sufficient amount of x-rays can be generated by this device to make it an excellent and flexible Compton backscattered x-ray (CBX) source for high throughput x-ray lithography and many other applications.

  13. A nonlinear plasma retroreflector for single pulse Compton backscattering

    NASA Astrophysics Data System (ADS)

    Palastro, J. P.; Kaganovich, D.; Gordon, D.; Hafizi, B.; Helle, M.; Penano, J.; Ting, A.

    2015-02-01

    Compton scattered x-rays can be generated using a configuration consisting of a single ultrashort laser pulse and a shaped gas target. Upon ionization the gas target serves as a plasma mirror that reflects the incident pulse providing a counter-propagating electromagnetic wiggler. While plasma mirrors are often conceived as linear Fresnel reflectors, we demonstrate that for high-intensity, ultrashort laser pulses the reflection results from two distinct nonlinear mechanisms. At lower densities, the reflection arises from the emission of an electromagnetic pulse during the saturation of the absolute Raman instability at the quarter critical surface. At higher densities the reflection of the pulse from the critical surface sets up a density fluctuation that acts as a Bragg-like reflector. These mechanisms, occurring in a non-perturbative regime of laser-plasma interactions, are examined numerically in order to characterize the Compton scattered radiation.

  14. A novel Compton camera design featuring a rear-panel shield for substantial noise reduction in gamma-ray images

    NASA Astrophysics Data System (ADS)

    Nishiyama, T.; Kataoka, J.; Kishimoto, A.; Fujita, T.; Iwamoto, Y.; Taya, T.; Ohsuka, S.; Nakamura, S.; Hirayanagi, M.; Sakurai, N.; Adachi, S.; Uchiyama, T.

    2014-12-01

    After the Japanese nuclear disaster in 2011, large amounts of radioactive isotopes were released and still remain a serious problem in Japan. Consequently, various gamma cameras are being developed to help identify radiation hotspots and ensure effective decontamination operation. The Compton camera utilizes the kinematics of Compton scattering to contract images without using a mechanical collimator, and features a wide field of view. For instance, we have developed a novel Compton camera that features a small size (13 × 14 × 15 cm3) and light weight (1.9 kg), but which also achieves high sensitivity thanks to Ce:GAGG scintillators optically coupled wiith MPPC arrays. By definition, in such a Compton camera, gamma rays are expected to scatter in the ``scatterer'' and then be fully absorbed in the ``absorber'' (in what is called a forward-scattered event). However, high energy gamma rays often interact with the detector in the opposite direction - initially scattered in the absorber and then absorbed in the scatterer - in what is called a ``back-scattered'' event. Any contamination of such back-scattered events is known to substantially degrade the quality of gamma-ray images, but determining the order of gamma-ray interaction based solely on energy deposits in the scatterer and absorber is quite difficult. For this reason, we propose a novel yet simple Compton camera design that includes a rear-panel shield (a few mm thick) consisting of W or Pb located just behind the scatterer. Since the energy of scattered gamma rays in back-scattered events is much lower than that in forward-scattered events, we can effectively discriminate and reduce back-scattered events to improve the signal-to-noise ratio in the images. This paper presents our detailed optimization of the rear-panel shield using Geant4 simulation, and describes a demonstration test using our Compton camera.

  15. Method and apparatus for measuring lung density by Compton backscattering

    DOEpatents

    Loo, Billy W.; Goulding, Frederick S.

    1991-01-01

    The density of the lung of a patient suffering from pulmonary edema is monitored by irradiating the lung by a single collimated beam of monochromatic photons and measuring the energies of photons Compton backscattered from the lung by a single high-resolution, high-purity germanium detector. A compact system geometry and a unique data extraction scheme are utilized to monimize systematic errors due to the presence of the chestwall and multiple scattering.

  16. Dual color x-rays from Thomson or Compton sources

    NASA Astrophysics Data System (ADS)

    Petrillo, V.; Bacci, A.; Curatolo, C.; Ferrario, M.; Maroli, C.; Rau, J. V.; Ronsivalle, C.; Serafini, L.; Vaccarezza, C.; Venturelli, M.

    2015-05-01

    We analyze the possibility of producing two color X or γ radiation by Thomson/Compton back-scattering between a high intensity laser pulse and a two-energy level electron beam, constituted by a couple of beamlets separated in time and/or energy obtained by a photoinjector with comb laser techniques and linac velocity bunching. The parameters of the Thomson source at SPARC_LAB have been simulated, proposing a set of values for a realistic experiments.

  17. Unsaturated Comptonization of isotropic photon spectra by relativistic electrons

    NASA Technical Reports Server (NTRS)

    Loeb, Abraham; Mckee, Christopher F.; Lahav, Ofer

    1991-01-01

    The multiple scattering approach for evaluating the transformation of an arbitrary soft photon spectrum as a result of unsaturated Compton scatterings in a medium of relativistic electrons is explored. The medium is assumed to be infinite and spatially homogeneous but may be time-dependent, and the photons are isotropic. It is shown that the distortion of a radiation spectrum can be described analytically in a compact form using the Fourier transform of the single-scattering probability. In the nonrelativistic case, the validity of the known analytical results derived from the Kompaneets (1957) equation is extended to arbitrary electron distribution functions and photon spectra. For relativistic electrons, simple expressions are obtained for the total energy that is transferred from the electrons to the photons and for the distortion in the Rayleigh-Jeans regime of a blackbody spectrum. It is demonstrated that the treatment applies to Comptonization in a relativistic jet and that Comptonization of very soft trapped photons by semirelativistic electrons in an expanding medium leads naturally to a log Gaussian spectrum, of the form observed in blazars.

  18. The dose from Compton backscatter screening.

    PubMed

    Rez, Peter; Metzger, Robert L; Mossman, Kenneth L

    2011-04-01

    Systems based on the detection of Compton backscattered X rays have been deployed for screening personnel for weapons and explosives. Similar principles are used for screening vehicles at border-crossing points. Based on well-established scattering cross sections and absorption coefficients in conjunction with reasonable estimates of the image contrast and resolution, the entrance skin dose and the dose at a depth of 1 cm can be calculated. The effective dose can be estimated using the same conversion coefficients as used to convert exposure measurements to the effective dose. It is shown that the effective dose is highly dependent on image resolution (i.e. pixel size).The effective doses for personnel screening systems are unlikely to be in compliance with the American National Standards Institute standard NS 43.17 unless the pixel sizes are >4 mm. Nevertheless, calculated effective doses are well below doses associated with health effects. PMID:21068018

  19. The Compton Mirror in NGC 4151

    NASA Technical Reports Server (NTRS)

    Poutanen, Juri; Sikora, Marek; Begelman, Mitchell C.; Magdziarz, Pawel

    1996-01-01

    We show that the sharp cutoff in the hard X-ray spectrum of NGC 4151, unusual for Seyfert 1 galaxies, can be reconciled with the average Seyfert 1 spectrum if we assume that the central source is completely hidden from our line of sight by the thick part of the accretion disk or by the broad emission-line clouds. The observed X-ray radiation is produced by scattering of the Seyfert 1 type spectrum in the higher, cooler parts of the accretion disk corona, or in a wind. A sharp cutoff appears as a result of the Compton recoil effect. This model naturally explains a discrepancy regarding the inclination of the central source, inferred to be low (face-on) from observations of the iron K-alpha emission line, but inferred to be high on the basis of optical and UV observations.

  20. The GSFC Advanced Compton Telescope (ACT)

    NASA Astrophysics Data System (ADS)

    Hartman, R.; Fichtel, C.; Kniffen, D.; Trombka, J.; Stacy, G.

    1983-08-01

    A new telescope is being developed at GSFC for the study of point sources of gamma rays in the energy range 1-30 MeV. Using the detection principle of a Compton scatter in a 2.5 cm thick NaI(Tl) detector followed by absorption in a 15 cm thick NaI(Tl) detector, the telescope uses a rocking collimator for field-of-view reduction and background subtraction. Background reduction techniques include lead-plastic scintillator shielding, pulse shape discrimination and Anger camera operation to both NaI detectors, as well as a time-of-flight measurement between them. The instrument configuration and status is described.

  1. The Compton Observatory Science Workshop

    NASA Technical Reports Server (NTRS)

    Shrader, Chris R. (Editor); Gehrels, Neil (Editor); Dennis, Brian (Editor)

    1992-01-01

    The Compton Observatory Science Workshop was held in Annapolis, Maryland on September 23-25, 1991. The primary purpose of the workshop was to provide a forum for the exchange of ideas and information among scientists with interests in various areas of high energy astrophysics, with emphasis on the scientific capabilities of the Compton Observatory. Early scientific results, as well as reports on in-flight instrument performance and calibrations are presented. Guest investigator data products, analysis techniques, and associated software were discussed. Scientific topics covered included active galaxies, cosmic gamma ray bursts, solar physics, pulsars, novae, supernovae, galactic binary sources, and diffuse galactic and extragalactic emission.

  2. First-Generation Hybrid Compact Compton Imager

    SciTech Connect

    Cunningham, M; Burks, M; Chivers, D; Cork, C; Fabris, L; Gunter, D; Krings, T; Lange, D; Hull, E; Mihailescu, L; Nelson, K; Niedermayr, T; Protic, D; Valentine, J; Vetter, K; Wright, D

    2005-11-07

    At Lawrence Livermore National Laboratory, we are pursuing the development of a gamma-ray imaging system using the Compton effect. We have built our first generation hybrid Compton imaging system, and we have conducted initial calibration and image measurements using this system. In this paper, we present the details of the hybrid Compton imaging system and initial calibration and image measurements.

  3. Synchrotron and inverse Compton emission from expanding sources in jets - Application to SS 433

    NASA Technical Reports Server (NTRS)

    Band, David L.; Grindlay, Jonathan E.

    1986-01-01

    The formalism for an expanding source is extended to include continuous injection of electrons and the production of X-rays by inverse Compton scattering of external photons and synchrotron-self-Compton scattering. The model is applied to the expanding nonthermal sources entrained in the jets of SS 433. These sources are found capable of producing both the flaring radio component and the X-ray fluxes only if the relativistic electrons and the magnetic field are far out of equipartition. If the expanding source in the jets is in equipartition, the X-rays may originate from a stationary source within the binary system, which is self-absorbed at radio frequencies and produces X-rays by inverse Compton scattering of optical photons from the binary.

  4. Real-space Green;s function calculations of Compton profiles

    SciTech Connect

    Mattern, Brian A.; Seidler, Gerald T.; Kas, Joshua J.; Pacold, Joseph I.; Rehr, John J.

    2012-09-05

    We report the development of a first-principles, real-space Green's function method for calculation of Compton profiles in the impulse approximation. For crystalline Be, we find excellent agreement with prior theoretical treatments requiring periodicity, with prior experimental measurements of the Compton profile, and with present measurements of the dynamical structure factor via nonresonant inelastic x-ray scattering (often also called x-ray Thomson scattering in the plasma physics community). We also find good agreement with prior experimental results for the Compton profile of Cu. This approach can be extended to disordered and very high-temperature systems, such as 'warm dense matter,' where theories presently used for the interpretation of inelastic x-ray scattering include condensed phase effects only at a perturbative level.

  5. Reggeometry of lepton- and hadron-induced reactions

    SciTech Connect

    Fiore, Roberto; Jenkovszky, Laszlo; Lavorini, Adelmo; Salii, Andrii

    2013-04-15

    We append a simple Pomeron pole amplitude by t and Q{sup 2}, MV dependencies inspired by geometrical ideas. The experimentally transition from soft to hard dynamics is realized by the introduction of a two-component Pomeron with different Q{sup 2} and M{sub V}-dependent residues. A unified description of deeply virtual Compton scattering (DVCS), of exclusive electroproduction of all vector mesons as well as of elastic pp scattering is suggested.

  6. Noise evaluation of Compton camera imaging for proton therapy.

    PubMed

    Ortega, P G; Torres-Espallardo, I; Cerutti, F; Ferrari, A; Gillam, J E; Lacasta, C; Llosá, G; Oliver, J F; Sala, P R; Solevi, P; Rafecas, M

    2015-03-01

    Compton Cameras emerged as an alternative for real-time dose monitoring techniques for Particle Therapy (PT), based on the detection of prompt-gammas. As a consequence of the Compton scattering process, the gamma origin point can be restricted onto the surface of a cone (Compton cone). Through image reconstruction techniques, the distribution of the gamma emitters can be estimated, using cone-surfaces backprojections of the Compton cones through the image space, along with more sophisticated statistical methods to improve the image quality. To calculate the Compton cone required for image reconstruction, either two interactions, the last being photoelectric absorption, or three scatter interactions are needed. Because of the high energy of the photons in PT the first option might not be adequate, as the photon is not absorbed in general. However, the second option is less efficient. That is the reason to resort to spectral reconstructions, where the incoming γ energy is considered as a variable in the reconstruction inverse problem. Jointly with prompt gamma, secondary neutrons and scattered photons, not strongly correlated with the dose map, can also reach the imaging detector and produce false events. These events deteriorate the image quality. Also, high intensity beams can produce particle accumulation in the camera, which lead to an increase of random coincidences, meaning events which gather measurements from different incoming particles. The noise scenario is expected to be different if double or triple events are used, and consequently, the reconstructed images can be affected differently by spurious data. The aim of the present work is to study the effect of false events in the reconstructed image, evaluating their impact in the determination of the beam particle ranges. A simulation study that includes misidentified events (neutrons and random coincidences) in the final image of a Compton Telescope for PT monitoring is presented. The complete chain of

  7. Noise evaluation of Compton camera imaging for proton therapy

    NASA Astrophysics Data System (ADS)

    Ortega, P. G.; Torres-Espallardo, I.; Cerutti, F.; Ferrari, A.; Gillam, J. E.; Lacasta, C.; Llosá, G.; Oliver, J. F.; Sala, P. R.; Solevi, P.; Rafecas, M.

    2015-02-01

    Compton Cameras emerged as an alternative for real-time dose monitoring techniques for Particle Therapy (PT), based on the detection of prompt-gammas. As a consequence of the Compton scattering process, the gamma origin point can be restricted onto the surface of a cone (Compton cone). Through image reconstruction techniques, the distribution of the gamma emitters can be estimated, using cone-surfaces backprojections of the Compton cones through the image space, along with more sophisticated statistical methods to improve the image quality. To calculate the Compton cone required for image reconstruction, either two interactions, the last being photoelectric absorption, or three scatter interactions are needed. Because of the high energy of the photons in PT the first option might not be adequate, as the photon is not absorbed in general. However, the second option is less efficient. That is the reason to resort to spectral reconstructions, where the incoming γ energy is considered as a variable in the reconstruction inverse problem. Jointly with prompt gamma, secondary neutrons and scattered photons, not strongly correlated with the dose map, can also reach the imaging detector and produce false events. These events deteriorate the image quality. Also, high intensity beams can produce particle accumulation in the camera, which lead to an increase of random coincidences, meaning events which gather measurements from different incoming particles. The noise scenario is expected to be different if double or triple events are used, and consequently, the reconstructed images can be affected differently by spurious data. The aim of the present work is to study the effect of false events in the reconstructed image, evaluating their impact in the determination of the beam particle ranges. A simulation study that includes misidentified events (neutrons and random coincidences) in the final image of a Compton Telescope for PT monitoring is presented. The complete chain of

  8. The Compton Gamma Ray Observatory

    NASA Astrophysics Data System (ADS)

    Gehrels, N.; Chipman, E.; Kniffen, D.

    1994-06-01

    The Arthur Holly Compton Gamma Ray Observatory Compton) is the second in NASA's series of great Observatories. Launched on 1991 April 5, Compton represents a dramatic increase in capability over previous gamma-ray missions. The spacecraft and scientific instruments are all in good health, and many significant discoveries have already been made. We describe the capabilities of the four scientific instruments, and the observing program of the first 2 years of the mission. Examples of early discoveries by Compton are enumerated, including the discovery that gamma-ray bursts are isotropic but spatially inhomogeneous in their distribution; the discovery of a new class of high-energy extragalacatic gamma-ray sources, the gamma-ray AGNs; the discovery of emission from SN 1987A in the nuclear line of Co-57; and the mapping of emission from Al-26 in the interstellar medium (ISM) near the Galactic center. Future observations will include deep surveys of selected regions of the sky, long-tem studies of individual objects, correlative studies of objects at gamma-ray and other energies, a Galactic plane survey at intermediate gamma-ray energies, and improved statistics on gamma-ray bursts to search for small anisotropies. After completion of the all-sky survey, a Guest Investigator program is in progress with guest observers' time share increasing from 30% upward for the late mission phases.

  9. The Compton Gamma Ray Observatory

    NASA Technical Reports Server (NTRS)

    Gehrels, N.; Chipman, E.; Kniffen, D.

    1994-01-01

    The Arthur Holly Compton Gamma Ray Observatory Compton) is the second in NASA's series of great Observatories. Launched on 1991 April 5, Compton represents a dramatic increase in capability over previous gamma-ray missions. The spacecraft and scientific instruments are all in good health, and many significant discoveries have already been made. We describe the capabilities of the four scientific instruments, and the observing program of the first 2 years of the mission. Examples of early discoveries by Compton are enumerated, including the discovery that gamma-ray bursts are isotropic but spatially inhomogeneous in their distribution; the discovery of a new class of high-energy extragalacatic gamma-ray sources, the gamma-ray AGNs; the discovery of emission from SN 1987A in the nuclear line of Co-57; and the mapping of emission from Al-26 in the interstellar medium (ISM) near the Galactic center. Future observations will include deep surveys of selected regions of the sky, long-tem studies of individual objects, correlative studies of objects at gamma-ray and other energies, a Galactic plane survey at intermediate gamma-ray energies, and improved statistics on gamma-ray bursts to search for small anisotropies. After completion of the all-sky survey, a Guest Investigator program is in progress with guest observers' time share increasing from 30% upward for the late mission phases.

  10. Spectral signatures of compact sources in the inverse Compton catastrophe limit

    NASA Astrophysics Data System (ADS)

    Petropoulou, M.; Piran, T.; Mastichiadis, A.

    2015-09-01

    The inverse Compton catastrophe is defined as a dramatic rise in the luminosity of inverse Compton scattered photons. It is described by a non-linear loop of radiative processes that sets in for high values of the electron compactness and is responsible for the efficient transfer of energy from electrons to photons, predominantly through inverse Compton scatterings. We search for the conditions that drive a magnetized non-thermal source to the inverse Compton catastrophe regime and study its multiwavelength (MW) photon spectrum. We develop a generic analytical framework and use numerical calculations as a backup to the analytical predictions. We find that the escaping radiation from a source in the Compton catastrophe regime bears some unique features. The MW photon spectrum is a broken power law with a break at ˜mec2 due to the onset of the Klein-Nishina suppression. The spectral index below the break energy depends on the electron and magnetic compactnesses logarithmically, while it is independent of the electron power-law index (s). The maximum radiating power emerges typically in the γ-ray regime, at energies ˜mec2 (˜γmax mec2) for s > 2 (s ≲ 2), where γmax is the maximum Lorentz factor of the injected electron distribution. We apply the principles of the inverse Compton catastrophe to blazars and γ-ray bursts using the analytical framework we developed, and show how these can be used to impose robust constraints on the source parameters.

  11. Dvcs at Hermes

    NASA Astrophysics Data System (ADS)

    Marukyan, Hrachya

    2016-02-01

    Deeply virtual Compton scattering process was studied widely at the HERMES experiment through measurements of various cross-section asymmetries. These measurements exploited the rich data collected at HERMES on scattering a longitudinally polarized lepton (electron/positron) beam off unpolarized, longitudinally and transversely polarized hydrogen targets, unpolarized and longitudinally polarized deuterium targets, as well as unpolarized nuclear targets. The operation of a recoil detector during the last two years of HERMES running enabled for the full kinematic reconstruction of the events of exclusively produced real photons and a clean (with a background well below the 1%) measurement of the beam-helicity asymmetry. Also, first measurement of the beam-helicity asymmetry related to the associated deeply virtual Compton scattering process, where the proton is excited to a Δ-resonance state, was possible using the recoil detector information.

  12. Electron Pattern Recognition using trigger mode SOI pixel sensor for Advanced Compton Imaging

    NASA Astrophysics Data System (ADS)

    Shimazoe, K.; Yoshihara, Y.; Fairuz, A.; Koyama, A.; Takahashi, H.; Takeda, A.; Tsuru, T.; Arai, Y.

    2016-02-01

    Compton imaging is a useful method for localizing sub MeV to a few MeV gamma-rays and widely used for environmental and medical applications. The direction of recoiled electrons in Compton scattering process provides the additional information to limit the Compton cones and increases the sensitivity in the system. The capability of recoiled electron tracking using trigger-mode Silicon-On-Insulator (SOI) sensor is investigated with various radiation sources. The trigger-mode SOI sensor consists of 144 by 144 active pixels with 30 μm cells and the thickness of sensor is 500 μm. The sensor generates the digital output when it is hit by gamma-rays and 25 by 25 pixel pattern of surrounding the triggered pixel is readout to extract the recoiled electron track. The electron track is successfully observed for 60Co and 137Cs sources, which provides useful information for future electron tracking Compton camera.

  13. LASER-ELECTRON COMPTON INTERACTION IN PLASMA CHANNELS

    SciTech Connect

    POGORELSKY,I.V.

    1998-10-01

    A concept of high intensity femtosecond laser synchrotron source (LSS) is based on Compton backscattering of focused electron and laser beams. The short Rayleigh length of the focused laser beam limits the length of interaction to a few picoseconds. However, the technology of the high repetition rate high-average power picosecond lasers required for high put through LSS applications is not developed yet. Another problem associated with the picosecond laser pulses is undesirable nonlinear effects occurring when the laser photons are concentrated in a short time interval. To avoid the nonlinear Compton scattering, the laser beam has to be split, and the required hard radiation flux is accumulated over a number of consecutive interactions that complicates the LSS design. In order to relieve the technological constraints and achieve a practically feasible high-power laser synchrotron source, we propose to confine the laser-electron interaction region in the extended plasma channel. This approach permits to use nanosecond laser pulses instead of the picosecond pulses. That helps to avoid the nonlinear Compton scattering regime and allows to utilize already existing technology of the high-repetition rate TEA CO{sub 2} lasers operating at the atmospheric pressure. We demonstrate the advantages of the channeled LSS approach by the example of the prospective polarized positron source for Japan Linear Collider.

  14. Compton suppressed LaBr3 detection system for use in nondestructive spent fuel assay

    NASA Astrophysics Data System (ADS)

    Bender, S.; Heidrich, B.; Ünlü, K.

    2015-06-01

    Current methods for safeguarding and accounting for spent nuclear fuel in reprocessing facilities are extremely resource and time intensive. The incorporation of autonomous passive gamma-ray detectors into the procedure could make the process significantly less burdensome. In measured gamma-ray spectra from spent nuclear fuel, the Compton continuum from dominant fission product photopeaks obscure the lower energy lines from other isotopes. The application of Compton suppression to gamma-ray measurements of spent fuel may reduce this effect and allow other less intense, lower energy peaks to be detected, potentially improving the accuracy of multivariate analysis algorithms. Compton suppressed spectroscopic measurements of spent nuclear fuel using HPGe, LaBr3, and NaI(Tl) primary detectors were performed. Irradiated fuel was measured in two configurations: as intact fuel elements viewed through a collimator and as feed solutions in a laboratory to simulate the measurement of a dissolved process stream. These two configurations allowed the direct assessment and quantification of the differences in measured gamma-ray spectra from the application of Compton suppression. In the first configuration, several irradiated fuel elements of varying cooling times from the Penn State Breazeale Reactor spent fuel inventory were measured using the three collimated Compton suppression systems. In the second geometry, Compton suppressed measurements of two samples of Approved Test Material commercial fuel elements were recorded inside the guard detector annulus to simulate the siphoning of small quantities from the main process stream for long dwell measurement periods. Compton suppression was found to improve measured gamma-ray spectra of spent fuel for multivariate analysis by notably lowering the Compton continuum from dominant photopeaks such as 137Cs and 140La, due to scattered interactions in the detector, which allowed more spectral features to be resolved. There was a

  15. Compact Laser-Compton X-ray Source Development

    NASA Astrophysics Data System (ADS)

    Yeh, Po-Chun

    The state-of-the-art X-ray source based on inverse-Compton scattering between a high-brightness, relativistic electron beam produced by an X-band RF accelerator and a high-intensity laser pulse generated by chirped-pulse amplification (CPA) has been carried out by our research team at Lawrence Livermore National Laboratory. This system is called "Compact Laser-Compton X-ray Source". The applications include nuclear resonance fluorescence, medical imaging and therapy, and nuclear waste imaging and assay. One of the key factors in this system is how we know the interaction happened in the vacuum chamber, which is the spectrometer of electron beams. The other key factor is the interaction after the spectrometer, which is the outgoing X-ray. In this thesis, the work in the simulation for the result of the interaction between electrons and the laser, the calibration of spectrometer, and laser focus characterization are discussed.

  16. Prototype TIGRE Compton γ-ray balloon-borne telescope

    NASA Astrophysics Data System (ADS)

    Bhattacharya, D.; O'Neill, T. J.; Akyüz, A.; Samimi, J.; Zych, A. D.

    2004-02-01

    A prototype balloon-borne telescope is being constructed for γ-ray observations in the MeV energy range. The Tracking and Imaging Gamma-Ray Experiment (TIGRE) uses multi-layers of thin silicon detectors to track and measure the energy losses of Compton recoil electrons. When combined with the direction and energy of the Compton scattered γ-ray a unique incident direction for each photon event is determined. This facilitates background rejection, improved sensitivity and image reconstruction. The converter/tracker also serves as an electron-positron pair detector for γ-rays up to 100 MeV. The initial continental US flight will be used to determine the sub-orbital atmospheric backgrounds and search for polarized γ-emission for the Crab pulsar. Longer southern hemisphere flights with an enhanced instrument will map out the 26Al emissions from the galactic center region.

  17. New Compton densitometer for measuring pulmonary edema

    SciTech Connect

    Loo, B.W.; Goulding, F.S.; Simon, D.S.

    1985-10-01

    Pulmonary edema is the pathological increase of extravascular lung water found most often in patients with congestive heart failure and other critically ill patients who suffer from intravenous fluid overload. A non-invasive lung density monitor that is accurate, easily portable, safe and inexpensive is needed for clinical evaluation of pulmonary edema. Other researchers who have employed Compton scattering techniques generally used systems of extended size and detectors with poor energy resolution. This has resulted in significant systematic biases from multiply-scattered photons and larger errors in counting statistics at a given radiation dose to the patient. We are proposing a patented approach in which only backscattered photons are measured with a high-resolution HPGe detector in a compact system geometry. By proper design and a unique data extraction scheme, effects of the variable chest wall on lung density measurements are minimized. Preliminary test results indicate that with a radioactive source of under 30 GBq, it should be possible to make an accurate lung density measurement in one minute, with a risk of radiation exposure to the patient a thousand times smaller than that from a typical chest x-ray. The ability to make safe, frequent lung density measurements could be very helpful for monitoring the course of P.E. at the hospital bedside or outpatient clinics, and for evaluating the efficacy of therapy in clinical research. 6 refs., 5 figs.

  18. Accurate, low-energy Compton polarimetry for Hall C at Jefferson Lab

    NASA Astrophysics Data System (ADS)

    Jones, Donald

    2012-03-01

    A new Compton polarimeter has recently been commissioned in Hall C at Jefferson Lab in Newport News, VA, to provide a non-invasive, continuous measurement of electron beam polarization. The new Compton polarimeter is currently measuring electron beam polarization for Qweak, an experiment with a strict error budget allowing a combined statistical and systematic error of only ±1% for beam polarization. Using well-established techniques we are able to determine electron beam polarization by measuring the scattering asymmetry of both the backscattered photons and the scattered electrons. Although the photon and electron detectors provide somewhat independent measurements they share the common systematic of the laser polarization. I discuss the optical setup for the photon target used in the Compton polarimeter and recent efforts in reducing systematic error in determination of laser polarization.

  19. Description and interpretation of DVCS measurements

    NASA Astrophysics Data System (ADS)

    Kumerički, Krešimir; Müller, Dieter

    2016-03-01

    Having in mind the well-known limitations of certain models of generalized parton distributions (GPDs), we show that the allegedly universal GPDs, describing both deeply virtual Compton scattering (DVCS) and deeply virtual meson production (DVMP) data, fail to describe measurements of deep inelastic scattering. We present a new global DVCS fit that describes reasonably the world data set, which includes now also new measurements from Hall A and CLAS collaborations. We also explicitly illustrate that Compton form factors (CFFs) cannot be unambiguously extracted from photon electroproduction measurements off unpolarized proton alone and we argue that it is more reliable to interpret such measurements in terms of certain CFF combinations, where still some care is needed in order to estimate the propagated error. Joint proceedings contribution, based on two talks given by the authors at the 6th International conference on Physics Opportunities at Electron-Ion colliders (POETIC6)

  20. GEANT4 simulation of the effects of Doppler energy broadening in Compton imaging.

    PubMed

    Uche, C Z; Cree, M J; Round, W H

    2011-09-01

    A Monte Carlo approach was used to study the effects of Doppler energy broadening on Compton camera performance. The GEANT4 simulation toolkit was used to model the radiation transport and interactions with matter in a simulated Compton camera. The low energy electromagnetic physics model of GEANT4 incorporating Doppler broadening developed by Longo et al. was used in the simulations. The camera had a 9 × 9 cm scatterer and a 10 × 10 cm absorber with a scatterer to-absorber separation of 5 cm. Modelling was done such that only the effects of Doppler broadening were taken into consideration and effects of scatterer and absorber thickness and pixelation were not taken into account, thus a 'perfect' Compton camera was assumed. Scatterer materials were either silicon or germanium and the absorber material was cadmium zinc telluride. Simulations were done for point sources 10 cm in front of the scatterer. The results of the simulations validated the use of the low energy model of GEANT4. As expected, Doppler broadening was found to degrade the Compton camera imaging resolution. For a 140.5 keV source the resulting full-width-at-half-maximum (FWHM) of the point source image without accounting for Doppler broadening and using a silicon scatterer was 0.58 mm. This degraded to 7.1 mm when Doppler broadening was introduced and degraded further to 12.3 mm when a germanium scatterer was used instead of silicon. But for a 511 keV source, the FWHM was better than for a 140 keV source. The FWHM improved to 2.4 mm for a silicon scatterer and 4.6 mm for a germanium scatterer. Our result for silicon at 140.5 keV is in very good agreement with that published by An et al. PMID:21556971

  1. Measurement and simulation of a Compton suppression system for safeguards application

    NASA Astrophysics Data System (ADS)

    Lee, Seung Kyu; Seo, Hee; Won, Byung-Hee; Lee, Chaehun; Shin, Hee-Sung; Na, Sang-Ho; Song, Dae-Yong; Kim, Ho-Dong; Park, Geun-Il; Park, Se-Hwan

    2015-11-01

    Plutonium (Pu) contents in spent nuclear fuels, recovered uranium (U) or uranium/transuranium (U/TRU) products must be measured in order to secure the safeguardability of a pyroprocessing facility. Self-induced X-Ray fluorescence (XRF) and gamma-ray spectroscopy are useful techniques for determining Pu-to-U ratios and Pu isotope ratios of spent fuel. Photon measurements of spent nuclear fuel by using high-resolution spectrometers such as high-purity germanium (HPGe) detectors show a large continuum background in the low-energy region, which is due in large part to Compton scattering of energetic gamma rays. This paper proposes a Compton suppression system for reducing of the Compton continuum background. In the present study, the system was configured by using an HPGe main detector and a BGO (bismuth germanate: Bi4Ge3O12) guard detector. The system performances for gamma-ray measurement and XRF were evaluated by means of Monte Carlo simulations and measurements of the radiation source. The Monte Carlo N-Particle eXtended (MCNPX) simulations were performed using the same geometry as for the experiments, and considered, for exact results, the production of secondary electrons and photons. As a performance test of the Compton suppression system, the peak-to-Compton ratio, which is a figure of merit to evaluate the gamma-ray detection, was enhanced by a factor of three or more when the Compton suppression system was used.

  2. DETECTION AND IMAGING OF THE CRAB NEBULA WITH THE NUCLEAR COMPTON TELESCOPE

    SciTech Connect

    Bandstra, M. S.; Bellm, E. C.; Boggs, S. E.; Perez-Becker, D.; Zoglauer, A.; Chang, H.-K.; Chiu, J.-L.; Liang, J.-S.; Chang, Y.-H.; Liu, Z.-K.; Hung, W.-C.; Huang, M.-H. A.; Chiang, S. J.; Run, R.-S.; Lin, C.-H.; Amman, M.; Luke, P. N.; Jean, P.; Von Ballmoos, P.; Wunderer, C. B.

    2011-09-01

    The Nuclear Compton Telescope (NCT) is a balloon-borne Compton telescope designed for the study of astrophysical sources in the soft gamma-ray regime (200 keV-20 MeV). NCT's 10 high-purity germanium crossed-strip detectors measure the deposited energies and three-dimensional positions of gamma-ray interactions in the sensitive volume, and this information is used to restrict the initial photon to a circle on the sky using the Compton scatter technique. Thus NCT is able to perform spectroscopy, imaging, and polarization analysis on soft gamma-ray sources. NCT is one of the next generation of Compton telescopes-the so-called compact Compton telescopes (CCTs)-which can achieve effective areas comparable to the Imaging Compton Telescope's with an instrument that is a fraction of the size. The Crab Nebula was the primary target for the second flight of the NCT instrument, which occurred on 2009 May 17 and 18 in Fort Sumner, New Mexico. Analysis of 29.3 ks of data from the flight reveals an image of the Crab at a significance of 4{sigma}. This is the first reported detection of an astrophysical source by a CCT.

  3. Inspection of reinforced concrete samples by Compton backscattering technique

    NASA Astrophysics Data System (ADS)

    Boldo, E. M.; Appoloni, C. R.

    2014-02-01

    Reinforced concrete structures require frequent monitoring to ensure the concrete quality during its service life and for evaluation of in situ existing conditions. Compton backscattering of gamma rays is a nondestructive technique used for material characterization and detection of defects and inclusions in materials and can be employed on reinforced concrete. The methodology allows one-sided inspection of large structures, is relatively inexpensive and can be portable. The concept is based on detection of backscattered radiation produced from a collimated beam aimed at the sample. By measuring the spectrum of these scattered gamma rays it is possible to determine local density perturbations. In this work we used the Compton backscattering technique to locate and measure steel, defects and crushed stone inside concrete. The samples were irradiated with gamma rays from a Ø2 mm diameter collimated 241Am (100 mCi) source and the inelastically scattered photons were recorded at an angle of 135° by a high resolution CdTe semiconductor detector. Scanning was achieved by lateral movement of the sample blocks across the source and detector field of view in steps of 1 mm. A previous optimization of the experimental setup was performed with Monte Carlo simulation. The results showed that it was possible to locate inclusions and defects with Ø8 mm positioned at a depth of 20 mm below the surface of the sample. It was observed that aggregates such as crushed stone could mask defects at specific points due to high attenuation of the incident and scattered beam.

  4. Access to generalized parton distributions at COMPASS

    SciTech Connect

    Nowak, Wolf-Dieter

    2015-04-10

    A brief experimentalist's introduction to Generalized Parton Distributions (GPDs) is given. Recent COMPASS results are shown on transverse target-spin asymmetries in hard exclusive ρ{sup 0} production and their interpretation in terms of a phenomenological model as indication for chiral-odd, transverse GPDs is discussed. For deeply virtual Compton scattering, it is briefly outlined how to access GPDs and projections are shown for future COMPASS measurements.

  5. Polarized Positive and Negative Muon Beams to perform DVCS Measurements at COMPASS

    SciTech Connect

    D'Hose, Nicole

    2009-09-02

    The high energies available at CERN, and the option of using either positive or negative polarized muon beams, make the fixed-target COMPASS set-up a unique place for studying GPDs, through Deeply Virtual Compton Scattering (DVCS). A GPD program is part of the Medium and Long Term Plans at COMPASS [1]. This contribution presents the methodology and the goal of such experiments.

  6. GPD phenomenology and DVCS fitting. Entering the high-precision era

    NASA Astrophysics Data System (ADS)

    Kumerički, Krešimir; Liuti, Simonetta; Moutarde, Hervé

    2016-06-01

    We review the phenomenological framework for accessing Generalized Parton Distributions (GPDs) using measurements of Deeply Virtual Compton Scattering (DVCS) from a proton target. We describe various GPD models and fitting procedures, emphasizing specific challenges posed both by the internal structure and properties of the GPD functions and by their relation to observables. Bearing in mind forthcoming data of unprecedented accuracy, we give a set of recommendations to better define the pathway for a precise extraction of GPDs from experiment.

  7. Quark Orbital Angular Momentum and Exclusive Processes at HERMES

    SciTech Connect

    Ellinghaus, F.

    2006-11-17

    A first attempt for a model-dependent extraction of the orbital angular momentum of quarks in the nucleon has been made, based on HERMES data on exclusive processes and their description in terms of generalized parton distributions. An overview of the HERMES data on hard exclusive electroproduction of real photons (Deeply-Virtual Compton Scattering) and mesons is given, focusing on the measurements relevant to the extraction of quark orbital angular momentum.

  8. Generalized parton distributions in nuclei

    SciTech Connect

    Vadim Guzey

    2009-12-01

    Generalized parton distributions (GPDs) of nuclei describe the distribution of quarks and gluons in nuclei probed in hard exclusive reactions, such as e.g. deeply virtual Compton scattering (DVCS). Nuclear GPDs and nuclear DVCS allow us to study new aspects of many traditional nuclear effects (nuclear shadowing, EMC effect, medium modifications of the bound nucleons) as well as to access novel nuclear effects. In my talk, I review recent theoretical progress in the area of nuclear GPDs.

  9. Exotic Effects at the Charm Threshold and Other Novel Physics Topics at JLab-12 GeV

    SciTech Connect

    Brodsky, Stanley J.; /SLAC

    2012-05-03

    I briefly survey a number of novel hadron physics topics which can be investigated with the 12 GeV upgrade at J-Lab. The topics include new the formation of exotic heavy quark resonances accessible above the charm threshold, intrinsic charm and strangeness phenomena, the exclusive Sivers effect, hidden-color Fock states of nuclei, local two-photon interactions in deeply virtual Compton scattering, and non-universal antishadowing.

  10. Positrons at Jefferson Laboratory

    SciTech Connect

    Thomas, A W

    2009-09-01

    We review the compelling case for establishing a capability to accelerate positrons at Jefferson Lab. The potential appplications range from the study of two-photon exchange and deeply-virtual Compton scattering to exploiting the charge current weak interaction to probe the flavor structure of hadrons and nuclei. There are also fascinating ideas for using such a capability to discover new physics beyond the Standard Model of nuclear and particle physics.

  11. Compton interaction of free electrons with intense low frequency radiation

    NASA Technical Reports Server (NTRS)

    Illarionov, A. F.; Kompaneyets, D. A.

    1978-01-01

    Electron behavior in an intense low frequency radiation field, with induced Compton scattering as the primary mechanism of interaction, is investigated. Evolution of the electron energy spectrum is studied, and the equilibrium spectrum of relativistic electrons in a radiation field with high brightness temperature is found. The induced radiation pressure and heating rate of an electron gas are calculated. The direction of the induced pressure depends on the radiation spectrum. The form of spectrum, under the induced force can accelerate electrons to superrelativistic energies is found.

  12. Optical inverse-Compton emission from clusters of galaxies

    NASA Astrophysics Data System (ADS)

    Yamazaki, Ryo; Loeb, Abraham

    2015-10-01

    Shocks around clusters of galaxies accelerate electrons which upscatter the cosmic microwave background photons to higher energies. We use an analytical model to calculate this inverse-Compton (IC) emission, taking into account the effects of additional energy losses via synchrotron and Coulomb scattering. We find that the surface brightness of the optical IC emission increases with redshift and halo mass. The IC emission surface brightness, 32-34 mag arcsec-2, for massive clusters is potentially detectable by the newly developed Dragonfly Telephoto Array.

  13. Spectral properties of Compton inverse radiation: Application of Compton beams

    NASA Astrophysics Data System (ADS)

    Bulyak, Eugene; Urakawa, Junji

    2014-05-01

    Compton inverse radiation emitted due to backscattering of laser pulses off the relativistic electrons possesses high spectral density and high energy of photons - in hard x-ray up to gamma-ray energies - because of short wavelength of laser radiation as compared with the classical electromagnetic devices such as undulators. In this report, the possibility of such radiation to monochromatization by means of collimation is studied. Two approaches have been considered for the description of the spectral-angular density of Compton radiation based on the classical field theory and on the quantum electrodynamics. As is shown, both descriptions produce similar total spectra. On the contrary, angular distribution of the radiation is different: the classical approach predicted a more narrow radiation cone. Also proposed and estimated is a method of the 'electronic' monochromatization based on the electronic subtraction of the two images produced by the electron beams with slightly different energies. A 'proof-of-principle' experiment of this method is proposed for the LUXC facility of KEK (Japan).

  14. Compton polarimeter for 10-30 keV x rays.

    PubMed

    Weber, S; Beilmann, C; Shah, C; Tashenov, S

    2015-09-01

    We present a simple and versatile polarimeter for x rays in the energy range of 10-30 keV. It uses Compton scattering in low-Z materials such as beryllium or boron carbide. The azimuthal distribution of the scattered x rays is sampled by an array of 12 silicon PIN diodes operated at room temperature. We evaluated the polarimetry performance using Monte-Carlo simulations and show experimental results. PMID:26429432

  15. Compton polarimeter for 10–30 keV x rays

    SciTech Connect

    Weber, S.; Beilmann, C.; Shah, C.; Tashenov, S.

    2015-09-15

    We present a simple and versatile polarimeter for x rays in the energy range of 10–30 keV. It uses Compton scattering in low-Z materials such as beryllium or boron carbide. The azimuthal distribution of the scattered x rays is sampled by an array of 12 silicon PIN diodes operated at room temperature. We evaluated the polarimetry performance using Monte-Carlo simulations and show experimental results.

  16. Statistical simulation of multiple Compton backscattering process

    NASA Astrophysics Data System (ADS)

    Potylitsyn, A. P.; Kolchuzhkin, A. M.

    2014-09-01

    A number of laboratories are currently developing monochromatic sources of X-rays and gamma quanta based on the Compton backscattering (CBS) of laser photons by relativistic electrons. Modern technologies are capable of providing a concentration of electrons and photons in the interaction point such that each primary electron can emit several hard photons. In contrast to the well-known nonlinear CBS process, in which an initial electron "absorbs" a few laser photons and emits a single hard one, the above-mentioned process can be called a multiple CBS process and is characterized by a mean number of emitted photons. The present paper is devoted to simulating the parameters of a beam of back scattered quanta based on the Monte Carlo technique. It is shown that, even in the case of strong collimation of a resulting photon beam, the radiation monochromaticity may deteriorate because of the contribution coming from the multiple photon emission, which is something that must be considered while designing new CBS sources.

  17. Radiation therapy at compact Compton sources.

    PubMed

    Jacquet, Marie; Suortti, Pekka

    2015-09-01

    The principle of the compact Compton source is presented briefly. In collision with an ultrarelativistic electron bunch a laser pulse is back-scattered as hard X-rays. The radiation cone has an opening of a few mrad, and the energy bandwidth is a few percent. The electrons that have an energy of the order of a few tens of MeV either circulate in storage ring, or are injected to a linac at a frequency of 10-100 MHz. At the interaction point the electron bunch collides with the laser pulse that has been amplified in a Fabry-Perot resonator. There are several machines in design or construction phase, and projected fluxes are 10(12) to 10(14) photons/s. The flux available at 80 keV from the ThomX machine is compared with that used in the Stereotactic Synchrotron Radiation Therapy clinical trials. It is concluded that ThomX has the potential of serving as the radiation source in future radiation therapy programs, and that ThomX can be integrated in hospital environment. PMID:25752735

  18. Compton Dry-Cask Imaging System

    ScienceCinema

    None

    2013-05-28

    The Compton-Dry Cask Imaging Scanner is a system that verifies and documents the presence of spent nuclear fuel rods in dry-cask storage and determines their isotopic composition without moving or opening the cask. For more information about this project, visit http://www.inl.gov/rd100/2011/compton-dry-cask-imaging-system/

  19. Compton Dry-Cask Imaging System

    SciTech Connect

    2011-01-01

    The Compton-Dry Cask Imaging Scanner is a system that verifies and documents the presence of spent nuclear fuel rods in dry-cask storage and determines their isotopic composition without moving or opening the cask. For more information about this project, visit http://www.inl.gov/rd100/2011/compton-dry-cask-imaging-system/

  20. First electron beam polarization measurements with a Compton polarimeter at Jefferson Laboratory

    SciTech Connect

    Maud Baylac; E. Burtin; C. Cavata; S. Escoffier; B. Frois; D. Lhuillier; F. Marie; J. Martino; D. Neyret; T. Pussieux; P.Y. Bertin; Kees de Jager; J. Mitchell

    2002-03-01

    A Compton polarimeter has been installed in Hall A at Jefferson Laboratory. This letter reports on the first electron beam polarization measurements performed during the HAPPEX experiment at an electron energy of 3.3 GeV and an average current of 40 muA. The heart of this device is a Fabry-Perot cavity which increased the luminosity for Compton scattering in the interaction region so much that a 1.4% statistical accuracy could be obtained within one hour, with a 3.3% total error.

  1. Linearly polarized photons from Compton backscattering of laser light for nuclear resonance fluorescence experiments

    NASA Astrophysics Data System (ADS)

    Ohgaki, H.; Noguchi, T.; Sugiyama, S.; Yamazaki, T.; Mikado, T.; Chiwaki, M.; Yamada, K.; Suzuki, R.; Sei, N.

    1994-12-01

    Elastically scattered photons from 208Pb(γ pol, γ) have been measured with completely polarized photons. The polarized photons (laser Compton photons) can be generated by Compton backscattering of laser light. The energy of the polarized LCPs ranges from 1 to 10 MeV by using a Q-switched Nd:YAG laser and the storage ring TERAS at Electrotechnical Laboratory. We can rotate the polarization axis of the LCPs by using the laser polarization controller to diminish the systematic error in the measurement system. Parities of J = 1 levels in 208Pb, Ex = 5.514 and 4.841 MeV, were clearly determined to be negative.

  2. Why compton-suppressed germanium detector arrays?

    SciTech Connect

    Diamond, R.M.

    1993-10-01

    Nuclear spectroscopic studies have provided a strong incentive to obtain {gamma}-ray detectors with increasingly better energy resolution, higher full-energy peak efficiencies, and greater sensitivity or resolving power. A major step was the introduction of Ge detectors in the early 60`s. But because of the low atomic number of Ge they have a poor response function; a majority of interacting gamma rays of moderate energy Compton scatter out of the detector leaving a large low-energy background. The remedy was to add a Compton-suppression shield made of NaI around the Ge crystal, and if interactions occurred simultaneously in the NaI scintillator and in the Ge detector to veto that event. Efficiencies also increased greatly when an English-Danish collaboration assembled five Ge detectors, each with a NaI suppressor, into the first array at the end of 1980. Obviously, a system of five such detectors gave much better statistics than the usual two bare detectors used for obtaining coincidence data (by a factor of 10). A few years later, another major improvement came with replacement of the NaI suppressors with shields made of the much denser bismuth germanate (BGO) as scintillator, as these could be thinner leading to arrays with of order 20 detectors. Use of such a large number of detectors led to the realization that for cascades of coincident gamma rays, as in going down a band, the improvement in the peak/background ratio observed and already appreciated in going from singles spectra to gated (double-) coincidence spectra continued when doubly-gated triple-coincidence data were compared for the first time to singly-gated double-coincidence ones. The higher-gated spectra were much cleaner and more selective, though with poorer statistics, and the advantages of higher folds and efficiencies led to the proposals for the larger 4{pi} arrays of today, Eurogam and GASP in Europe and Gammasphere in the U.S.

  3. Prospects for DVCS measurements using the COMPASS spectrometer at CERN

    SciTech Connect

    Kouznetsov, O.

    2011-07-15

    The study of exclusive reactions like Deeply Virtual Compton Scattering (DVCS) and Deeply Virtual Meson Production (DVMP) is one major part of the future COMPASS program to investigate nucleon structure through Generalized Parton Distributions (GPD). The high energy of the muon beam allows to measure the x{sub Bj}-dependence of the t-slope of the DVCS cross section and to study nucleon tomography. The use of positive and negative polarized muon beams allows to determine the Beam Charge and Spin Difference of the DVCS cross sections to access the real part of the Compton form factor related to the dominant GPD H. As a second phase a transversely polarized proton target will be used to collect data to constrain the GPD E. In preparation of the future measurements two DVCS test runs were performed in 2008 and 2009.

  4. GPD physics with polarized muon beams at COMPASS-II

    SciTech Connect

    Ferrero, Andrea [CEA-Saclay, DSM Collaboration: COMPASS Collaboration

    2013-04-15

    A major part of the future COMPASS program is dedicated to the investigation of the nucleon structure through Deeply Virtual Compton Scattering (DVCS) and Deeply Virtual Meson Production (DVMP). COMPASS will measure DVCS and DVMP reactions with a high intensity muon beam of 160 GeV and a 2.5 m-long liquid hydrogen target surrounded by a new TOF system. The availability of muon beams with high energy and opposite charge and polarization will allow to access the Compton form factor related to the dominant GPD H and to study the x{sub B}-dependence of the t-slope of the pure DVCS cross section and to study nucleon tomography. Projections on the achievable accuracies and preliminary results of pilot measurements will be presented.

  5. Prospects for DVCS measurements using the COMPASS spectrometer at CERN

    NASA Astrophysics Data System (ADS)

    Kouznetsov, O.

    2011-07-01

    The study of exclusive reactions like Deeply Virtual Compton Scattering (DVCS) and Deeply Virtual Meson Production (DVMP) is one major part of the future COMPASS program to investigate nucleon structure through Generalized Parton Distributions (GPD). The high energy of the muon beam allows to measure the xBj-dependence of the t-slope of the DVCS cross section and to study nucleon tomography. The use of positive and negative polarized muon beams allows to determine the Beam Charge and Spin Difference of the DVCS cross sections to access the real part of the Compton form factor related to the dominant GPD H. As a second phase a transversely polarized proton target will be used to collect data to constrain the GPD E. In preparation of the future measurements two DVCS test runs were performed in 2008 and 2009.

  6. External inverse-Compton emission from jetted tidal disruption events

    NASA Astrophysics Data System (ADS)

    Lu, Wenbin; Kumar, Pawan

    2016-05-01

    The recent discoveries of Sw J1644+57 and Sw J2058+05 show that tidal disruption events (TDEs) can launch relativistic jets. Super-Eddington accretion produces a strong radiation field of order Eddington luminosity. In a jetted TDE, electrons in the jet will inverse-Compton scatter the photons from the accretion disc and wind (external radiation field). Motivated by observations of thermal optical-UV spectra in Sw J2058+05 and several other TDEs, we assume the spectrum of the external radiation field intercepted by the relativistic jet to be blackbody. Hot electrons in the jet scatter this thermal radiation and produce luminosities 1045-1048 erg s- 1 in the X/γ-ray band. This model of thermal plus inverse-Compton radiation is applied to Sw J2058+05. First, we show that the blackbody component in the optical-UV spectrum most likely has its origin in the super-Eddington wind from the disc. Then, using the observed blackbody component as the external radiation field, we show that the X-ray luminosity and spectrum are consistent with the inverse-Compton emission, under the following conditions: (1) the jet Lorentz factor is Γ ≃ 5-10; (2) electrons in the jet have a power-law distribution dN_e/dγ _e ∝ γ _e^{-p} with γmin ˜ 1 and p = 2.4; (3) the wind is mildly relativistic (Lorentz factor ≳ 1.5) and has isotropic-equivalent mass-loss rate ˜ 5 M⊙ yr- 1. We describe the implications for jet composition and the radius where jet energy is converted to radiation.

  7. Simple analytic expressions for correcting the factorizable formula for Compton

    NASA Astrophysics Data System (ADS)

    Lajohn, L. A.; Pratt, R. H.

    2016-05-01

    The factorizable form of the relativistic impulse approximation (RIA) expression for Compton scattering doubly differential cross sections (DDCS) becomes progressively less accurate as the binding energy of the ejected electron increases. This expression, which we call the RKJ approximation, makes it possible to obtain the Compton profile (CP) from measured DDCS. We have derived three simple analytic expressions, each which can be used to correct the RKJ error for the atomic K-shell CP obtained from DDCS for any atomic number Z. The expression which is the most general is valid over a broad range of energy ω and scattering angle θ, a second expression which is somewhat simpler is valid at very high ω but over most θ, and the third which is the simplest is valid at small θ over a broad range of ω. We demonstrate that such expressions can yield a CP accurate to within a 1% error over 99% of the electron momentum distribution range of the Uranium K-shell CP. Since the K-shell contribution dominates the extremes of the whole atom CP (this is where the error of RKJ can exceed an order of magnitude), this region can be of concern in assessing the bonding properties of molecules as well as semiconducting materials.

  8. A new telescope for wide-band gamma-ray astronomy: The Silicon Compton Recoil Telescope (SCRT)

    NASA Astrophysics Data System (ADS)

    Tuemer, O. Tuemay; Ait-Ouamer, Farid; Blair, Scott C.; Case, Gary L.; O'Neill, Brendan P.; O'Neill, Terrence J.; White, R. Stephen; Zych, Allen D.

    1994-06-01

    A new prototype gamma-ray telescope is described which is sensitive from 0.3 to 30 MeV as a Compton telescope and to 100 MeV as a pair detector. The Silicon Compton Recoil Telescope (SCRT) uses multilayers of silicon strip detectors as a Compton gamma-ray converter. Recoil electrons are tracked with the silicon strip detectors, and their energy losses and directions are measured. The direction and energy of the Compton-scattered gamma rays are measured with CsI(Tl)-photodiode detectors. Thus unique directions and energies are found for each incident gamma ray for the first time and without the background of overlapping rings. SCRT is the first Compton telescope to image the gamma-ray sky directly. It can also detect electron-positron pairs from gamma rays above 5 MeV, extending SCRT's sensitivity to above 100 MeV. Typical resolutions are 3% (FWHM) in energy at 2 MeV and 0.5 deg (1 sigma) in angle. The proposed prototype SCRT instrument has a sensitive area of 650 sq cm, a detection efficiency of 3%, a size reduction by about an order of magnitude, and a sensitivity of 15 millicrab for a typical Compton Observatory exposure. SCRT can also measure the polarization of the incident gamma rays, especially at low energies and large scattered angles. Simulation calculations and a discussion of results with a laboratory model are presented.

  9. Compton backscattering for the calibration of KEDR tagging system

    NASA Astrophysics Data System (ADS)

    Kaminskiy, V. V.; Muchnoi, N. Yu; Zhilich, V. N.

    2014-08-01

    KEDR detector has the tagging system (TS) to study the gamma-gamma processes. To determine the two-photon invariant mass, the energies of the scattered at small angles electrons and positrons are measured by the magnetic spectrometer embedded into the lattice of the VEPP-4M collider. The energy resolution (scattered electron/positron energy resolution divided by the beam energy) of this spectrometer varies from 0.6% to 0.03% depending on the electron/positron energy. The Compton backscattering of laser radiation on the electron/positron beam is used for the accurate energy scale and resolution calibration of the tagging system. The report covers the design, recent results and current status of the KEDR TS calibration system.

  10. A calibration system for Compton polarimetry at e+e- linear colliders

    NASA Astrophysics Data System (ADS)

    Vormwald, B.; List, J.; Vauth, A.

    2016-01-01

    Polarimetry with permille-level precision is essential for future electron-positron linear colliders. Compton polarimeters can reach negligible statistical uncertainties within seconds of measurement time. The dominating systematic uncertainties originate from the response and alignment of the detector which records the Compton scattered electrons. The robust baseline technology for the Compton polarimeters foreseen at future linear colliders is based on an array of gas Cherenkov detectors read out by photomultipliers. In this paper, we will present a calibration method which promises to monitor nonlinearities in the response of such a detector at the level of a few permille. This method has been implemented in an LED-based calibration system which matches the existing prototype detector. The performance of this calibration system is sufficient to control the corresponding contribution to the total uncertainty on the extracted polarisation to better than 0.1%.

  11. Analysis of the electronic structure of ZrO{sub 2} by Compton spectroscopy

    SciTech Connect

    Mahammad, F. M.; Mahammed, S. F.; Kumar, R.; Vijay, Y. K.; Sharma, B. K.; Sharma, G.

    2013-07-15

    The electronic structure of ZrO{sub 2} is studied using the Compton scattering technique. The first-ever Compton profile measurement on polycrystalline ZrO{sub 2} was obtained using 59.54 keV gamma-rays emanating from the {sup 241}Am radioisotope. To explain the experimental data, we compute theoretical Compton profile values using the method of linear combination of atomic orbitals in the framework of density functional theory. The correlation scheme proposed by Perdew-Burke-Ernzerhof and the exchange scheme of Becke are considered. The ionic-model-based calculations for a number of configurations, i.e., Zr{sup +x}(O{sup -x/2}){sub 2} (0 {<=} x {<=} 2), are also performed to estimate the charge transfer on compound formation, and the study supports transfer of 1.5 electrons from Zr to O atoms.

  12. Resonant Compton cooling and annihilation line production in gamma-ray bursts

    NASA Technical Reports Server (NTRS)

    Preece, R. D.; Harding, A. K.

    1992-01-01

    Attention is given to a synchrotron self-Compton emission model for gamma-ray bursts which produces narrow annihilation features for a variety of field strengths, primary electron injection energies, and injection rates. In this model, primary electrons are injected and cooled by synchrotron emission in a strong, homogeneous magnetic field, resulting in a pair cascade. Multiple resonant scattering with cyclotron photons efficiently traps and cools pairs in the ground state to an average energy where the Compton energy loss rate is zero, which is in agreement with previous estimates of a Compton temperature. The particle distributions in the ground state are determined by numerically solving the Fokker-Planck equation in the steady state. In the case of isotropic injection of primary electrons, a significant narrow-line feature appears in the overall emission. In the case of beamed injection, the annihilation line is broadened to the extent that it would not be observable.

  13. Real space analysis of Compton profile of Heusler alloy Ni2TiAl

    NASA Astrophysics Data System (ADS)

    Sahariya, Jagrati; Mund, H. S.; Ahuja, B. L.

    2012-06-01

    Electron momentum density of Ni2TiAl alloy has been studied using Compton scattering technique. The experiment has been performed using 20 Ci 137Cs (661.65 keV) Compton spectrometer at an intermediate resolution of 0.34 a.u. To interpret the experimental data, we have calculated the Compton profiles using Hartree Fock and density functional theories within the frame work of linear combination of atomic orbitals (LCAO) method. The experimental data have been interpreted in term of autocorrelation function B(z) of the one electron wave function. The experimental B(z) function has been compared with the LCAO based theoretical B(z), to analyze the electronic and structural properties of Ni2TiAl.

  14. Bulk Comptonization by turbulence in accretion discs

    NASA Astrophysics Data System (ADS)

    Kaufman, J.; Blaes, O. M.

    2016-06-01

    Radiation pressure dominated accretion discs around compact objects may have turbulent velocities that greatly exceed the electron thermal velocities within the disc. Bulk Comptonization by the turbulence may therefore dominate over thermal Comptonization in determining the emergent spectrum. Bulk Comptonization by divergenceless turbulence is due to radiation viscous dissipation only. It can be treated as thermal Comptonization by solving the Kompaneets equation with an equivalent `wave' temperature, which is a weighted sum over the power present at each scale in the turbulent cascade. Bulk Comptonization by turbulence with non-zero divergence is due to both pressure work and radiation viscous dissipation. Pressure work has negligible effect on photon spectra in the limit of optically thin turbulence, and in this limit radiation viscous dissipation alone can be treated as thermal Comptonization with a temperature equivalent to the full turbulent power. In the limit of extremely optically thick turbulence, radiation viscous dissipation is suppressed, and the evolution of local photon spectra can be understood in terms of compression and expansion of the strongly coupled photon and gas fluids. We discuss the consequences of these effects for self-consistently resolving and interpreting turbulent Comptonization in spectral calculations in radiation magnetohydrodynamic simulations of high luminosity accretion flows.

  15. The Compton Gamma Ray Observatory

    NASA Astrophysics Data System (ADS)

    Gehrels, N.; Chipman, E.; Kniffen, D. A.

    1993-01-01

    The Arthur Holly Compton Gamma Ray Observatory (Compton) was launched by the Space Shuttle Atlantis on 5 April 1991. The spacecraft and instruments are in good health and returning exciting results. The mission provides nearly six orders of magnitude in spectral coverage, from 30 keV to 30 GeV, with sensitivity over the entire range an order of magnitude better than that of previous observations. The 16,000 kilogram observatory contains four instruments on a stabilized platform. The mission began normal operations on 16 May 1991 and is now over half-way through a full-sky survey. The mission duration is expected to be from six to ten years. A Science Support Center has been established at Goddard Space Flight Center for the purpose of supporting a vigorous Guest Investigator Program. New scientific results to date include: (1) the establishment of the isotropy, combined with spatial inhomogeneity, of the distribution of gamma-ray bursts in the sky; (2) the discovery of intense high energy (100 MeV) gamma-ray emission from 3C 279 and other quasars and BL Lac objects, making these the most distant and luminous gamma-ray sources ever detected; (3) one of the first images of a gamma-ray burst; (4) the observation of intense nuclear and position-annihilation gamma-ray lines and neutrons from several large solar flares; and (5) the detection of a third gamma-ray pulsar, plus several other transient and pulsing hard X-ray sources.

  16. Dense Plasma X-ray Scattering: Methods and Applications

    SciTech Connect

    Glenzer, S H; Lee, H J; Davis, P; Doppner, T; Falcone, R W; Fortmann, C; Hammel, B A; Kritcher, A L; Landen, O L; Lee, R W; Munro, D H; Redmer, R; Weber, S

    2009-08-19

    We have developed accurate x-ray scattering techniques to measure the physical properties of dense plasmas. Temperature and density are inferred from inelastic x-ray scattering data whose interpretation is model-independent for low to moderately coupled systems. Specifically, the spectral shape of the non-collective Compton scattering spectrum directly reflects the electron velocity distribution. In partially Fermi degenerate systems that have been investigated experimentally in laser shock-compressed beryllium, the Compton scattering spectrum provides the Fermi energy and hence the electron density. We show that forward scattering spectra that observe collective plasmon oscillations yield densities in agreement with Compton scattering. In addition, electron temperatures inferred from the dispersion of the plasmon feature are consistent with the ion temperature sensitive elastic scattering feature. Hence, theoretical models of the static ion-ion structure factor and consequently the equation of state of dense matter can be directly tested.

  17. Hidden baryons: The physics of Compton composites

    NASA Astrophysics Data System (ADS)

    Mayer, Frederick J.

    2016-06-01

    A large fraction of the mass-energy of the Universe appears to be composed of Compton composites. How is it then that these composites are not frequently observed in experiments? This paper addresses this question, and others, by reviewing recent publications that: 1) introduced Compton composites, 2) showed how and where they are formed and 3) explained how they interact with other systems. Though ubiquitous in many physical situations, Compton composites are almost completely hidden in experiments due to their unique interaction characteristics. Still, their presence has been indirectly observed, though not interpreted as such until recently. Looking to the future, direct-detection experiments are proposed that could verify the composites' components. It is with deep sadness that I dedicate this paper to my mentor, collaborator, and friend, Dr. John R. Reitz, who passed away within days of the publication of our paper “Compton Composites Late in the Early Universe”.

  18. RELATIVISTIC ACCRETION MEDIATED BY TURBULENT COMPTONIZATION

    SciTech Connect

    Socrates, Aristotle E-mail: socrates@astro.princeton.ed

    2010-08-10

    Black hole and neutron star accretion flows display unusually high levels of hard coronal emission in comparison to all other optically thick, gravitationally bound, turbulent astrophysical systems. Since these flows sit in deep relativistic gravitational potentials, their random bulk motions approach the speed of light, therefore allowing turbulent Comptonization to be an important effect. We show that the inevitable production of hard X-ray photons results from turbulent Comptonization in the limit where the turbulence is trans-sonic and the accretion power approaches the Eddington limit. In this regime, the turbulent Compton y-parameter approaches unity and the turbulent Compton temperature is a significant fraction of the electron rest mass energy, in agreement with the observed phenomena.

  19. Combining harmonic generation and laser chirping to achieve high spectral density in Compton sources

    NASA Astrophysics Data System (ADS)

    Terzić, Balša; Reeves, Cody; Krafft, Geoffrey A.

    2016-04-01

    Recently various laser-chirping schemes have been investigated with the goal of reducing or eliminating ponderomotive line broadening in Compton or Thomson scattering occurring at high laser intensities. As a next level of detail in the spectrum calculations, we have calculated the line smoothing and broadening expected due to incident beam energy spread within a one-dimensional plane wave model for the incident laser pulse, both for compensated (chirped) and unchirped cases. The scattered compensated distributions are treatable analytically within three models for the envelope of the incident laser pulses: Gaussian, Lorentzian, or hyperbolic secant. We use the new results to demonstrate that the laser chirping in Compton sources at high laser intensities: (i) enables the use of higher order harmonics, thereby reducing the required electron beam energies; and (ii) increases the photon yield in a small frequency band beyond that possible with the fundamental without chirping. This combination of chirping and higher harmonics can lead to substantial savings in the design, construction and operational costs of the new Compton sources. This is of particular importance to the widely popular laser-plasma accelerator based Compton sources, as the improvement in their beam quality enters the regime where chirping is most effective.

  20. Evaluation of detector material and radiation source position on Compton camera's ability for multitracer imaging.

    PubMed

    Uche, C Z; Round, W H; Cree, M J

    2012-09-01

    We present a study on the effects of detector material, radionuclide source and source position on the Compton camera aimed at realistic characterization of the camera's performance in multitracer imaging as it relates to brain imaging. The GEANT4 Monte Carlo simulation software was used to model the physics of radiation transport and interactions with matter. Silicon (Si) and germanium (Ge) detectors were evaluated for the scatterer, and cadmium zinc telluride (CZT) and cerium-doped lanthanum bromide (LaBr(3):Ce) were considered for the absorber. Image quality analyses suggest that the use of Si as the scatterer and CZT as the absorber would be preferred. Nevertheless, two simulated Compton camera models (Si/CZT and Si/LaBr(3):Ce Compton cameras) that are considered in this study demonstrated good capabilities for multitracer imaging in that four radiotracers within the nuclear medicine energy range are clearly visualized by the cameras. It is found however that beyond a range difference of about 2 cm for (113m)In and (18)F radiotracers in a brain phantom, there may be a need to rotate the Compton camera for efficient brain imaging. PMID:22829298