Sample records for developing portable low-cost

  1. Development of a Low-Cost, Noninvasive, Portable Visual Speech Recognition Program.

    PubMed

    Kohlberg, Gavriel D; Gal, Ya'akov Kobi; Lalwani, Anil K

    2016-09-01

    Loss of speech following tracheostomy and laryngectomy severely limits communication to simple gestures and facial expressions that are largely ineffective. To facilitate communication in these patients, we seek to develop a low-cost, noninvasive, portable, and simple visual speech recognition program (VSRP) to convert articulatory facial movements into speech. A Microsoft Kinect-based VSRP was developed to capture spatial coordinates of lip movements and translate them into speech. The articulatory speech movements associated with 12 sentences were used to train an artificial neural network classifier. The accuracy of the classifier was then evaluated on a separate, previously unseen set of articulatory speech movements. The VSRP was successfully implemented and tested in 5 subjects. It achieved an accuracy rate of 77.2% (65.0%-87.6% for the 5 speakers) on a 12-sentence data set. The mean time to classify an individual sentence was 2.03 milliseconds (1.91-2.16). We have demonstrated the feasibility of a low-cost, noninvasive, portable VSRP based on Kinect to accurately predict speech from articulation movements in clinically trivial time. This VSRP could be used as a novel communication device for aphonic patients. © The Author(s) 2016.

  2. Development and On-Field Testing of Low-Cost Portable System for Monitoring PM2.5 Concentrations.

    PubMed

    N Genikomsakis, Konstantinos; Galatoulas, Nikolaos-Fivos; I Dallas, Panagiotis; Candanedo Ibarra, Luis Miguel; Margaritis, Dimitris; S Ioakimidis, Christos

    2018-04-01

    Recent developments in the field of low-cost sensors enable the design and implementation of compact, inexpensive and portable sensing units for air pollution monitoring with fine-detailed spatial and temporal resolution, in order to support applications of wider interest in the area of intelligent transportation systems (ITS). In this context, the present work advances the concept of developing a low-cost portable air pollution monitoring system (APMS) for measuring the concentrations of particulate matter (PM), in particular fine particles with a diameter of 2.5 μm or less (PM2.5). Specifically, this paper presents the on-field testing of the proposed low-cost APMS implementation using roadside measurements from a mobile laboratory equipped with a calibrated instrument as the basis of comparison and showcases its accuracy on characterizing the PM2.5 concentrations on 1 min resolution in an on-road trial. Moreover, it demonstrates the intended application of collecting fine-grained spatio-temporal PM2.5 profiles by mounting the developed APMS on an electric bike as a case study in the city of Mons, Belgium.

  3. Development and On-Field Testing of Low-Cost Portable System for Monitoring PM2.5 Concentrations

    PubMed Central

    Galatoulas, Nikolaos-Fivos; I. Dallas, Panagiotis; Candanedo Ibarra, Luis Miguel; Margaritis, Dimitris; S. Ioakimidis, Christos

    2018-01-01

    Recent developments in the field of low-cost sensors enable the design and implementation of compact, inexpensive and portable sensing units for air pollution monitoring with fine-detailed spatial and temporal resolution, in order to support applications of wider interest in the area of intelligent transportation systems (ITS). In this context, the present work advances the concept of developing a low-cost portable air pollution monitoring system (APMS) for measuring the concentrations of particulate matter (PM), in particular fine particles with a diameter of 2.5 μm or less (PM2.5). Specifically, this paper presents the on-field testing of the proposed low-cost APMS implementation using roadside measurements from a mobile laboratory equipped with a calibrated instrument as the basis of comparison and showcases its accuracy on characterizing the PM2.5 concentrations on 1 min resolution in an on-road trial. Moreover, it demonstrates the intended application of collecting fine-grained spatio-temporal PM2.5 profiles by mounting the developed APMS on an electric bike as a case study in the city of Mons, Belgium. PMID:29614770

  4. Performance Assessment of a Custom, Portable, and Low-Cost Brain-Computer Interface Platform.

    PubMed

    McCrimmon, Colin M; Fu, Jonathan Lee; Wang, Ming; Lopes, Lucas Silva; Wang, Po T; Karimi-Bidhendi, Alireza; Liu, Charles Y; Heydari, Payam; Nenadic, Zoran; Do, An Hong

    2017-10-01

    Conventional brain-computer interfaces (BCIs) are often expensive, complex to operate, and lack portability, which confines their use to laboratory settings. Portable, inexpensive BCIs can mitigate these problems, but it remains unclear whether their low-cost design compromises their performance. Therefore, we developed a portable, low-cost BCI and compared its performance to that of a conventional BCI. The BCI was assembled by integrating a custom electroencephalogram (EEG) amplifier with an open-source microcontroller and a touchscreen. The function of the amplifier was first validated against a commercial bioamplifier, followed by a head-to-head comparison between the custom BCI (using four EEG channels) and a conventional 32-channel BCI. Specifically, five able-bodied subjects were cued to alternate between hand opening/closing and remaining motionless while the BCI decoded their movement state in real time and provided visual feedback through a light emitting diode. Subjects repeated the above task for a total of 10 trials, and were unaware of which system was being used. The performance in each trial was defined as the temporal correlation between the cues and the decoded states. The EEG data simultaneously acquired with the custom and commercial amplifiers were visually similar and highly correlated ( ρ = 0.79). The decoding performances of the custom and conventional BCIs averaged across trials and subjects were 0.70 ± 0.12 and 0.68 ± 0.10, respectively, and were not significantly different. The performance of our portable, low-cost BCI is comparable to that of the conventional BCIs. Platforms, such as the one developed here, are suitable for BCI applications outside of a laboratory.

  5. Portable, low-cost NMR with laser-lathe lithography produced microcoils.

    PubMed

    Demas, Vasiliki; Herberg, Julie L; Malba, Vince; Bernhardt, Anthony; Evans, Lee; Harvey, Christopher; Chinn, Sarah C; Maxwell, Robert S; Reimer, Jeffrey

    2007-11-01

    Nuclear Magnetic Resonance (NMR) is unsurpassed in its ability to non-destructively probe chemical identity. Portable, low-cost NMR sensors would enable on-site identification of potentially hazardous substances, as well as the study of samples in a variety of industrial applications. Recent developments in RF microcoil construction (i.e. coils much smaller than the standard 5mm NMR RF coils), have dramatically increased NMR sensitivity and decreased the limits-of-detection (LOD). We are using advances in laser pantographic microfabrication techniques, unique to LLNL, to produce RF microcoils for field deployable, high sensitivity NMR-based detectors. This same fabrication technique can be used to produce imaging coils for MRI as well as for standard hardware shimming or "ex-situ" shimming of field inhomogeneities typically associated with inexpensive magnets. This paper describes a portable NMR system based on the use of a 2 kg hand-held permanent magnet, laser-fabricated microcoils, and a compact spectrometer. The main limitations for such a system are the low resolution and sensitivity associated with the low field values and quality of small permanent magnets, as well as the lack of large amounts of sample of interest in most cases. The focus of the paper is on the setting up of this system, initial results, sensitivity measurements, discussion of the limitations and future plans. The results, even though preliminary, are promising and provide the foundation for developing a portable, inexpensive NMR system for chemical analysis. Such a system will be ideal for chemical identification of trace substances on site.

  6. A low-cost and portable realization on fringe projection three-dimensional measurement

    NASA Astrophysics Data System (ADS)

    Xiao, Suzhi; Tao, Wei; Zhao, Hui

    2015-12-01

    Fringe projection three-dimensional measurement is widely applied in a wide range of industrial application. The traditional fringe projection system has the disadvantages of high expense, big size, and complicated calibration requirements. In this paper we introduce a low-cost and portable realization on three-dimensional measurement with Pico projector. It has the advantages of low cost, compact physical size, and flexible configuration. For the proposed fringe projection system, there is no restriction to camera and projector's relative alignment on parallelism and perpendicularity for installation. Moreover, plane-based calibration method is adopted in this paper that avoids critical requirements on calibration system such as additional gauge block or precise linear z stage. What is more, error sources existing in the proposed system are introduced in this paper. The experimental results demonstrate the feasibility of the proposed low cost and portable fringe projection system.

  7. On Ex Situ NMR: Developing portable low-cost and/or single sided NMR/MRI

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Demas, V; Herberg, J; Maxwell, R

    2006-06-09

    Nuclear magnetic resonance spectroscopy (NMR) is of unsurpassed versatility in its ability to non-destructively probe for chemical identity. Portable, low-cost NMR sensors would enable on site identification of potentially hazardous substances, such as signatures from production of nuclear, chemical, and biological weapon agents, narcotics, explosives, toxins, and poisons. There exist however problems that need to be considered in the case of such sensors: (a) small-scale magnets produce inhomogeneous magnetic fields and therefore undesired Larmor frequency distributions that conceal much of the useful spectral information, and (b) sensitivity in most experiments decreases due to the inherently low and strongly inhomogeneous fieldsmore » associated with portable instruments. Our approach is to: (a) try to improve the field of low cost magnets either with hardware (e.g. magnet design and construction of ''shim coils'') or via special pulse sequences, where the field is ''effectively shimmed'' to appear homogeneous to the sample, and (b) to use microcoils to improve sensitivity and to allow focusing in smaller regions and therefore smaller static field variations. We have been working in setting up a table top, 2-Tesla permanent Halbach magnet system for tabletop NMR. The Spectrometer console is a Tecmag Apollo, controlled by a dell notebook. Currently an external linear chemagnetics rf amplifier is being used, though the power requirements for our system are quite low (a few Watts). The Magnetic Resonance lab in LLNL, has developed several types and sizes of microcoils, which have been proven to perform well for NMR experiments. We have evaluated an rf, 360 {micro}m O.D., microcoil probe that was built previously. We have finished mapping the magnetic field of the magnet. In the optimal position (in terms of field quality), the field inhomogeneity was at 17ppm. Preliminary fluorine spectra with a resolved two peak separation have now been obtained. For the field

  8. Ultra low-cost, portable smartphone optosensors for mobile point-of-care diagnostics

    NASA Astrophysics Data System (ADS)

    Wang, Li-Ju; Chang, Yu-Chung; Sun, Rongrong; Li, Lei

    2018-02-01

    Smartphone optosensors with integrated optical components make mobile point-of-care (MPoC) diagnostics be done near patients' side. It'll especially have a significant impact on healthcare delivery in rural or remote areas. Current FDA-approved PoC devices achieving clinical level are still at high cost and not affordable in rural hospitals. We present a series of ultra low-cost smartphone optical sensing devices for mobile point-of-care diagnosis. Aiming different targeting analytes and sensing mechanisms, we developed custom required optical components for each smartphone optosensros. These optical devices include spectrum readers, colorimetric readers for microplate, lateral flow device readers, and chemiluminescence readers. By integrating our unique designed optical components into smartphone optosening platform, the anlaytes can be precisely detected. Clinical testing results show the clinical usability of our smartphone optosensors. Ultra low-cost portable smartphone optosensors are affordable for rural/remote doctors.

  9. Design and Validation of a Low-Cost Portable Device to Quantify Postural Stability.

    PubMed

    Zhu, Yong

    2017-03-18

    Measurement of the displacement of the center-of-pressure (COP) is an important tool used in biomechanics to assess postural stability and human balance. The goal of this research was to design and validate a low-cost portable device that can offer a quick indication of the state of postural stability and human balance related conditions. Approximate entropy (ApEn) values reflecting the amount of irregularity hiding in COP oscillations were used to calculate the index. The prototype adopted a portable design using the measurements of the load cells located at the four corners of a low-cost force platform. The test subject was asked to stand on the device in a quiet, normal, upright stance for 30 s with eyes open and subsequently for 30 s with eyes closed. Based on the COP displacement signals, the ApEn values were calculated. The results indicated that the prototype device was capable of capturing the increase in regularity of postural control in the visual-deprivation conditions. It was also able to decipher the subtle postural control differences along anterior-posterior and medial-lateral directions. The data analysis demonstrated that the prototype would enable the quantification of postural stability and thus provide a low-cost portable device to assess many conditions related to postural stability and human balance such as aging and pathologies.

  10. Construction and Characterization of a Compact, Portable, Low-Cost Colorimeter for the Chemistry Lab

    ERIC Educational Resources Information Center

    Clippard, Carrie M.; Hughes, William; Chohan, Balwant S.; Sykes, Danny G.

    2016-01-01

    A low-cost and portable colorimeter was constructed featuring a low-voltage programmable color light sensor-to-frequency converter, a CMOS 8-bit microcontroller, and an LCD display. The instrument has successfully facilitated the introduction and application of spectroscopy to groups of middle school, high school, and undergraduate students. A…

  11. A low cost, disposable cable-shaped Al-air battery for portable biosensors

    NASA Astrophysics Data System (ADS)

    Fotouhi, Gareth; Ogier, Caleb; Kim, Jong-Hoon; Kim, Sooyeun; Cao, Guozhong; Shen, Amy Q.; Kramlich, John; Chung, Jae-Hyun

    2016-05-01

    A disposable cable-shaped flexible battery is presented using a simple, low cost manufacturing process. The working principle of an aluminum-air galvanic cell is used for the cable-shaped battery to power portable and point-of-care medical devices. The battery is catalyzed with a carbon nanotube (CNT)-paper matrix. A scalable manufacturing process using a lathe is developed to wrap a paper layer and a CNT-paper matrix on an aluminum wire. The matrix is then wrapped with a silver-plated copper wire to form the battery cell. The battery is activated through absorption of electrolytes including phosphate-buffered saline, NaOH, urine, saliva, and blood into the CNT-paper matrix. The maximum electric power using a 10 mm-long battery cell is over 1.5 mW. As a demonstration, an LED is powered using two groups of four batteries in parallel connected in series. Considering the material composition and the cable-shaped configuration, the battery is fully disposable, flexible, and potentially compatible with portable biosensors through activation by either reagents or biological fluids.

  12. Seq-Well: portable, low-cost RNA sequencing of single cells at high throughput.

    PubMed

    Gierahn, Todd M; Wadsworth, Marc H; Hughes, Travis K; Bryson, Bryan D; Butler, Andrew; Satija, Rahul; Fortune, Sarah; Love, J Christopher; Shalek, Alex K

    2017-04-01

    Single-cell RNA-seq can precisely resolve cellular states, but applying this method to low-input samples is challenging. Here, we present Seq-Well, a portable, low-cost platform for massively parallel single-cell RNA-seq. Barcoded mRNA capture beads and single cells are sealed in an array of subnanoliter wells using a semipermeable membrane, enabling efficient cell lysis and transcript capture. We use Seq-Well to profile thousands of primary human macrophages exposed to Mycobacterium tuberculosis.

  13. Low-cost chlorophyll meter (LCCM): portable measuring device for leaf chlorophyll

    NASA Astrophysics Data System (ADS)

    Hutomo E. P., Evan; Adibawa, Marcelinus Alfasisurya S.; Prilianti, Kestrilia R.; Heriyanto, Heriyanto; Brotosudarmo, Tatas H. P.

    2016-11-01

    Portable leaf chlorophyll meter, named low-cost chlorophyll meter (LCCM), has been created. This device was created to help farmer determining the health condition of plant based on the greenness level of leaf surface. According to previous studies, leaf greenness with a certain amount of chlorophyll level has a direct correlation with the amount of nitrogen in the leaf that indicates health of the plant and this fact needed to provide an estimate of further measures to keep the plants healthy. Device that enables to measure the leaf color change is soil plant analysis development (SPAD) meter 502 from Konica Minolta but it is relatively expensive. To answer the need of low-cost chlorophyll scanner device, this research conducted experiment using light reflectance as the base mechanism. Reflectance system from LCCM consists of near-infrared light emitting diode (LED) and red LED as light resources and photodiode. The output from both of light resources calculated using normalized difference vegetation index (NDVI) formula as the results fetched and displayed on the smartphone application using Bluetooth communication protocol. Finally, the scanner has been made as well as the Android application named NDVI Reader. The LCCM system which has been tested on 20 sample of cassava leaf with SPAD meter as a variable control showed coefficient of determination 0.9681 and root-mean-square error (RMSE) 0.014.

  14. Portable equipment for determining ripeness in Hass avocado using a low cost color sensor

    NASA Astrophysics Data System (ADS)

    Toro, Jessica; Daza, Carolina; Vega, Fabio; Diaz, Leonardo; Torres, Cesar

    2015-08-01

    The avocado is a one climacteric fruit that not ripe on the tree because it produces a maturation inhibitor that passes the fruit through the pedicel, the ripening occurs naturally during storage or to be induced as required. In post-harvest ripening stage is basically determined by experience of the farmer or buyer. In this word us developed portable equipment for determining ripeness is hass avocado using a low cost sensor color sensor TC3200 and LCD for display result. The prototype read of RGB color frequencies of the sensor and estimates the stage of ripeness in fourth different stages in post-harvest ripening.

  15. Low-cost, portable, robust and high-resolution single-camera stereo-DIC system and its application in high-temperature deformation measurements

    NASA Astrophysics Data System (ADS)

    Chi, Yuxi; Yu, Liping; Pan, Bing

    2018-05-01

    A low-cost, portable, robust and high-resolution single-camera stereo-digital image correlation (stereo-DIC) system for accurate surface three-dimensional (3D) shape and deformation measurements is described. This system adopts a single consumer-grade high-resolution digital Single Lens Reflex (SLR) camera and a four-mirror adaptor, rather than two synchronized industrial digital cameras, for stereo image acquisition. In addition, monochromatic blue light illumination and coupled bandpass filter imaging are integrated to ensure the robustness of the system against ambient light variations. In contrast to conventional binocular stereo-DIC systems, the developed pseudo-stereo-DIC system offers the advantages of low cost, portability, robustness against ambient light variations, and high resolution. The accuracy and precision of the developed single SLR camera-based stereo-DIC system were validated by measuring the 3D shape of a stationary sphere along with in-plane and out-of-plane displacements of a translated planar plate. Application of the established system to thermal deformation measurement of an alumina ceramic plate and a stainless-steel plate subjected to radiation heating was also demonstrated.

  16. A Portable, Low-Cost, LED Fluorimeter for Middle School, High School, and Undergraduate Chemistry Labs

    ERIC Educational Resources Information Center

    Wigton, Benjamin T.; Chohan, Balwant S.; McDonald, Cole; Johnson, Matt; Schunk, Doug; Kreuter, Rod; Sykes, Dan

    2011-01-01

    A low-cost portable fluorimeter was constructed using a 360 nm LED for excitation and a silicon photodiode for detection. The instrument is simple to operate and has been used to investigate fluorescent whitening agents extracted from various brands of paper, to determine the linear range and limit of detection of quinine in various commercial…

  17. A low-cost, portable optical sensing system with wireless communication compatible of real-time and remote detection of dissolved ammonia

    NASA Astrophysics Data System (ADS)

    Deng, Shijie; Doherty, William; McAuliffe, Michael AP; Salaj-Kosla, Urszula; Lewis, Liam; Huyet, Guillaume

    2016-06-01

    A low-cost and portable optical chemical sensor based ammonia sensing system that is capable of detecting dissolved ammonia up to 5 ppm is presented. In the system, an optical chemical sensor is designed and fabricated for sensing dissolved ammonia concentrations. The sensor uses eosin as the fluorescence dye which is immobilized on the glass substrate by a gas-permeable protection layer. A compact module is developed to hold the optical components, and a battery powered micro-controller system is designed to read out and process the data measured. The system operates without the requirement of laboratory instruments that makes it cost effective and highly portable. Moreover, the calculated results in the system can be transmitted to a PC wirelessly, which allows the remote and real-time monitoring of dissolved ammonia.

  18. Low-Cost, Portable, Multi-Wall Virtual Reality

    NASA Technical Reports Server (NTRS)

    Miller, Samuel A.; Misch, Noah J.; Dalton, Aaron J.

    2005-01-01

    Virtual reality systems make compelling outreach displays, but some such systems, like the CAVE, have design features that make their use for that purpose inconvenient. In the case of the CAVE, the equipment is difficult to disassemble, transport, and reassemble, and typically CAVEs can only be afforded by large-budget research facilities. We implemented a system like the CAVE that costs less than $30,000, weighs about 500 pounds, and fits into a fifteen-passenger van. A team of six people have unpacked, assembled, and calibrated the system in less than two hours. This cost reduction versus similar virtual-reality systems stems from the unique approach we took to stereoscopic projection. We used an assembly of optical chopper wheels and commodity LCD projectors to create true active stereo at less than a fifth of the cost of comparable active-stereo technologies. The screen and frame design also optimized portability; the frame assembles in minutes with only two fasteners, and both it and the screen pack into small bundles for easy and secure shipment.

  19. Choosing MUSE: Validation of a Low-Cost, Portable EEG System for ERP Research

    PubMed Central

    Krigolson, Olave E.; Williams, Chad C.; Norton, Angela; Hassall, Cameron D.; Colino, Francisco L.

    2017-01-01

    In recent years there has been an increase in the number of portable low-cost electroencephalographic (EEG) systems available to researchers. However, to date the validation of the use of low-cost EEG systems has focused on continuous recording of EEG data and/or the replication of large system EEG setups reliant on event-markers to afford examination of event-related brain potentials (ERP). Here, we demonstrate that it is possible to conduct ERP research without being reliant on event markers using a portable MUSE EEG system and a single computer. Specifically, we report the results of two experiments using data collected with the MUSE EEG system—one using the well-known visual oddball paradigm and the other using a standard reward-learning task. Our results demonstrate that we could observe and quantify the N200 and P300 ERP components in the visual oddball task and the reward positivity (the mirror opposite component to the feedback-related negativity) in the reward-learning task. Specifically, single sample t-tests of component existence (all p's < 0.05), computation of Bayesian credible intervals, and 95% confidence intervals all statistically verified the existence of the N200, P300, and reward positivity in all analyses. We provide with this research paper an open source website with all the instructions, methods, and software to replicate our findings and to provide researchers with an easy way to use the MUSE EEG system for ERP research. Importantly, our work highlights that with a single computer and a portable EEG system such as the MUSE one can conduct ERP research with ease thus greatly extending the possible use of the ERP methodology to a variety of novel contexts. PMID:28344546

  20. Choosing MUSE: Validation of a Low-Cost, Portable EEG System for ERP Research.

    PubMed

    Krigolson, Olave E; Williams, Chad C; Norton, Angela; Hassall, Cameron D; Colino, Francisco L

    2017-01-01

    In recent years there has been an increase in the number of portable low-cost electroencephalographic (EEG) systems available to researchers. However, to date the validation of the use of low-cost EEG systems has focused on continuous recording of EEG data and/or the replication of large system EEG setups reliant on event-markers to afford examination of event-related brain potentials (ERP). Here, we demonstrate that it is possible to conduct ERP research without being reliant on event markers using a portable MUSE EEG system and a single computer. Specifically, we report the results of two experiments using data collected with the MUSE EEG system-one using the well-known visual oddball paradigm and the other using a standard reward-learning task. Our results demonstrate that we could observe and quantify the N200 and P300 ERP components in the visual oddball task and the reward positivity (the mirror opposite component to the feedback-related negativity) in the reward-learning task. Specifically, single sample t -tests of component existence (all p 's < 0.05), computation of Bayesian credible intervals, and 95% confidence intervals all statistically verified the existence of the N200, P300, and reward positivity in all analyses. We provide with this research paper an open source website with all the instructions, methods, and software to replicate our findings and to provide researchers with an easy way to use the MUSE EEG system for ERP research. Importantly, our work highlights that with a single computer and a portable EEG system such as the MUSE one can conduct ERP research with ease thus greatly extending the possible use of the ERP methodology to a variety of novel contexts.

  1. Portable Welder

    NASA Technical Reports Server (NTRS)

    1984-01-01

    A low cost, low power, self-contained portable welding gun designed for joining thermoplastics which become soft when heated and harden when cooled was developed originally by NASA's Langley Research Center for repairing helicopter windshields. Welder has a broad range of applications for joining both thermoplastic materials in the aerospace, automotive, appliance, and construction industries. Welders portability and low power requirement allow its use on-site in any type of climate, with power supplied by a variety of portable sources.

  2. Portable, low-priced retinal imager for eye disease screening

    NASA Astrophysics Data System (ADS)

    Soliz, Peter; Nemeth, Sheila; VanNess, Richard; Barriga, E. S.; Zamora, Gilberto

    2014-02-01

    The objective of this project was to develop and demonstrate a portable, low-priced, easy to use non-mydriatic retinal camera for eye disease screening in underserved urban and rural locations. Existing portable retinal imagers do not meet the requirements of a low-cost camera with sufficient technical capabilities (field of view, image quality, portability, battery power, and ease-of-use) to be distributed widely to low volume clinics, such as the offices of single primary care physicians serving rural communities or other economically stressed healthcare facilities. Our approach for Smart i-Rx is based primarily on a significant departure from current generations of desktop and hand-held commercial retinal cameras as well as those under development. Our techniques include: 1) Exclusive use of off-the-shelf components; 2) Integration of retinal imaging device into low-cost, high utility camera mount and chin rest; 3) Unique optical and illumination designed for small form factor; and 4) Exploitation of autofocus technology built into present digital SLR recreational cameras; and 5) Integration of a polarization technique to avoid the corneal reflex. In a prospective study, 41 out of 44 diabetics were imaged successfully. No imaging was attempted on three of the subjects due to noticeably small pupils (less than 2mm). The images were of sufficient quality to detect abnormalities related to diabetic retinopathy, such as microaneurysms and exudates. These images were compared with ones taken non-mydriatically with a Canon CR-1 Mark II camera. No cases identified as having DR by expert retinal graders were missed in the Smart i-Rx images.

  3. A portable low-cost long-term live-cell imaging platform for biomedical research and education.

    PubMed

    Walzik, Maria P; Vollmar, Verena; Lachnit, Theresa; Dietz, Helmut; Haug, Susanne; Bachmann, Holger; Fath, Moritz; Aschenbrenner, Daniel; Abolpour Mofrad, Sepideh; Friedrich, Oliver; Gilbert, Daniel F

    2015-02-15

    Time-resolved visualization and analysis of slow dynamic processes in living cells has revolutionized many aspects of in vitro cellular studies. However, existing technology applied to time-resolved live-cell microscopy is often immobile, costly and requires a high level of skill to use and maintain. These factors limit its utility to field research and educational purposes. The recent availability of rapid prototyping technology makes it possible to quickly and easily engineer purpose-built alternatives to conventional research infrastructure which are low-cost and user-friendly. In this paper we describe the prototype of a fully automated low-cost, portable live-cell imaging system for time-resolved label-free visualization of dynamic processes in living cells. The device is light-weight (3.6 kg), small (22 × 22 × 22 cm) and extremely low-cost (<€1250). We demonstrate its potential for biomedical use by long-term imaging of recombinant HEK293 cells at varying culture conditions and validate its ability to generate time-resolved data of high quality allowing for analysis of time-dependent processes in living cells. While this work focuses on long-term imaging of mammalian cells, the presented technology could also be adapted for use with other biological specimen and provides a general example of rapidly prototyped low-cost biosensor technology for application in life sciences and education. Copyright © 2014 The Authors. Published by Elsevier B.V. All rights reserved.

  4. An Open-source Low-cost Portable Apparatus for Soil Fauna Sampling

    NASA Astrophysics Data System (ADS)

    Daliakopoulos, Ioannis; Wagner, Karl; Grillakis, Manolis; Apostolakis, Antonios; Tsanis, Ioannis

    2016-04-01

    A low-cost apparatus for the extraction of living soil animals from soil or litter samples is presented. The main unit consists of a modular bank system with three horizontal shelves designed to accommodate lamps and soil samples over funnel and jar systems for animal collection, thus serving as a practical and standardized modification of the well-documented Berlese-Tullgren funnel. Shelves are vertically adjustable, sliding on 5 mm threaded rods and securing with wing nuts for easy assembly/disassembly and stability. Shelf material is 4 mm plywood (or similar), laser-cut (or similar) to accommodate lamp sockets, tubes and funnels at respective levels. Soil samples are inserted in 10 cm tubes from standard Ø50 mm PVC piping that can also function as direct collection corers for softer soils. Tubes are fitted in the tube bank shelf, each directly under a 25 W reflector lamp and over a funnel and jar system. Lamps are located 25 mm over the tubes' top creating a relatively constant 10 oC temperature gradient that drives soil animals away from heat and light, and towards the bottom end of the tube which is fitted with a suitable fabric mesh. Standard 106 ml panelled jars, filled with a safe-to-handle preservative (e.g. propylene glycol) to the lower end of the funnel fitted in them, trap and preserve soil organisms until identification. The apparatus offers flat-pack portability and scalability using low-cost standard material. Design specifications and Drawing eXchange Format (dxf) files for apparatus reproduction are provided.

  5. Low-Cost, Robust, and Field Portable Smartphone Platform Photometric Sensor for Fluoride Level Detection in Drinking Water.

    PubMed

    Hussain, Iftak; Ahamad, Kamal Uddin; Nath, Pabitra

    2017-01-03

    Groundwater is the major source of drinking water for people living in rural areas of India. Pollutants such as fluoride in groundwater may be present in much higher concentration than the permissible limit. Fluoride does not give any visible coloration to water, and hence, no effort is made to remove or reduce the concentration of this chemical present in drinking water. This may lead to a serious health hazard for those people taking groundwater as their primary source of drinking water. Sophisticated laboratory grade tools such as ion selective electrodes (ISE) and portable spectrophotometers are commercially available for in-field detection of fluoride level in drinking water. However, such tools are generally expensive and require expertise to handle. In this paper, we demonstrate the working of a low cost, robust, and field portable smartphone platform fluoride sensor that can detect and analyze fluoride concentration level in drinking water. For development of the proposed sensor, we utilize the ambient light sensor (ALS) of the smartphone as light intensity detector and its LED flash light as an optical source. An android application "FSense" has been developed which can detect and analyze the fluoride concentration level in water samples. The custom developed application can be used for sharing of in-field sensing data from any remote location to the central water quality monitoring station. We envision that the proposed sensing technique could be useful for initiating a fluoride removal program undertaken by governmental and nongovernmental organizations here in India.

  6. Portable, battery-operated, fluorescence field microscope for the developing world

    NASA Astrophysics Data System (ADS)

    Miller, Andrew R.; Davis, Gregory; Pierce, Mark; Oden, Z. Maria; Richards-Kortum, Rebecca

    2010-02-01

    In many areas of the world, current methods for diagnosis of infectious diseases such as malaria and tuberculosis involve microscopic evaluation of a patient specimen. Advances in fluorescence microscopy can improve diagnostic sensitivity and reduce time and expertise necessary to interpret diagnostic results. However, modern research-grade microscopes are neither available nor appropriate for use in many settings in the developing world. To address this need, we designed, fabricated, and tested a portable, battery-powered, bright field and fluorescence inverted field microscope, optimized for infrastructural constraints of the developing world. We characterized an initial prototype constructed with rapidprototyping techniques, which utilized low-cost, over-the-counter components such as a battery-powered LED flashlight as the light source. The microscope exhibited suitable spatial resolution (0.8 μm) in fluorescence mode to resolve M. tuberculosis bacilli. In bright field mode, malaria parasites were resolvable at 1000x magnification. The initial prototype cost 480 USD and we estimate that the microscope can be manufactured for 230 USD. While future studies are planned to evaluate ease-of-use and reliability, our current system serves as a proof of concept that combined fluorescence and bright field microscopy is possible in a low-cost and portable system.

  7. Development of Fully Automated Low-Cost Immunoassay System for Research Applications.

    PubMed

    Wang, Guochun; Das, Champak; Ledden, Bradley; Sun, Qian; Nguyen, Chien

    2017-10-01

    Enzyme-linked immunosorbent assay (ELISA) automation for routine operation in a small research environment would be very attractive. A portable fully automated low-cost immunoassay system was designed, developed, and evaluated with several protein analytes. It features disposable capillary columns as the reaction sites and uses real-time calibration for improved accuracy. It reduces the overall assay time to less than 75 min with the ability of easy adaptation of new testing targets. The running cost is extremely low due to the nature of automation, as well as reduced material requirements. Details about system configuration, components selection, disposable fabrication, system assembly, and operation are reported. The performance of the system was initially established with a rabbit immunoglobulin G (IgG) assay, and an example of assay adaptation with an interleukin 6 (IL6) assay is shown. This system is ideal for research use, but could work for broader testing applications with further optimization.

  8. IQ-Station: A Low Cost Portable Immersive Environment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Eric Whiting; Patrick O'Leary; William Sherman

    2010-11-01

    The emergence of inexpensive 3D TV’s, affordable input and rendering hardware and open-source software has created a yeasty atmosphere for the development of low-cost immersive environments (IE). A low cost IE system, or IQ-station, fashioned from commercial off the shelf technology (COTS), coupled with a targeted immersive application can be a viable laboratory instrument for enhancing scientific workflow for exploration and analysis. The use of an IQ-station in a laboratory setting also has the potential of quickening the adoption of a more sophisticated immersive environment as a critical enabler in modern scientific and engineering workflows. Prior work in immersive environmentsmore » generally required either a head mounted display (HMD) system or a large projector-based implementation both of which have limitations in terms of cost, usability, or space requirements. The solution presented here provides an alternative platform providing a reasonable immersive experience that addresses those limitations. Our work brings together the needed hardware and software to create a fully integrated immersive display and interface system that can be readily deployed in laboratories and common workspaces. By doing so, it is now feasible for immersive technologies to be included in researchers’ day-to-day workflows. The IQ-Station sets the stage for much wider adoption of immersive environments outside the small communities of virtual reality centers.« less

  9. Portable image-manipulation software: what is the extra development cost?

    PubMed

    Ligier, Y; Ratib, O; Funk, M; Perrier, R; Girard, C; Logean, M

    1992-08-01

    A hospital-wide picture archiving and communication system (PACS) project is currently under development at the University Hospital of Geneva. The visualization and manipulation of images provided by different imaging modalities constitutes one of the most challenging component of a PACS. It was necessary to provide this visualization software on a number of types of workstations because of the varying requirements imposed by the range of clinical uses it must serve. The user interface must be the same, independent of the underlying workstation. In addition to a standard set of image-manipulation and processing tools, there is a need for more specific clinical tools that can be easily adapted to specific medical requirements. To achieve this goal, it was elected to develop a modular and portable software called OSIRIS. This software is available on two different operating systems (the UNIX standard X-11/OSF-Motif based workstations and the Macintosh family) and can be easily ported to other systems. The extra effort required to design such software in a modular and portable way was worthwhile because it resulted in a platform that can be easily expanded and adapted to a variety of specific clinical applications. Its portability allows users to benefit from the rapidly evolving workstation technology and to adapt the performance to suit their needs.

  10. Adapting smartphones for low-cost optical medical imaging

    NASA Astrophysics Data System (ADS)

    Pratavieira, Sebastião.; Vollet-Filho, José D.; Carbinatto, Fernanda M.; Blanco, Kate; Inada, Natalia M.; Bagnato, Vanderlei S.; Kurachi, Cristina

    2015-06-01

    Optical images have been used in several medical situations to improve diagnosis of lesions or to monitor treatments. However, most systems employ expensive scientific (CCD or CMOS) cameras and need computers to display and save the images, usually resulting in a high final cost for the system. Additionally, this sort of apparatus operation usually becomes more complex, requiring more and more specialized technical knowledge from the operator. Currently, the number of people using smartphone-like devices with built-in high quality cameras is increasing, which might allow using such devices as an efficient, lower cost, portable imaging system for medical applications. Thus, we aim to develop methods of adaptation of those devices to optical medical imaging techniques, such as fluorescence. Particularly, smartphones covers were adapted to connect a smartphone-like device to widefield fluorescence imaging systems. These systems were used to detect lesions in different tissues, such as cervix and mouth/throat mucosa, and to monitor ALA-induced protoporphyrin-IX formation for photodynamic treatment of Cervical Intraepithelial Neoplasia. This approach may contribute significantly to low-cost, portable and simple clinical optical imaging collection.

  11. Low cost attitude control system scanwheel development

    NASA Astrophysics Data System (ADS)

    Bialke, William; Selby, Vaughn

    1991-03-01

    In order to satisfy a growing demand for low cost attitude control systems for small spacecraft, development of low cost scanning horizon sensor coupled to a low cost/low power consumption Reaction Wheel Assembly was initiated. This report addresses the details of the versatile design resulting from this effort. Tradeoff analyses for each of the major components are included, as well as test data from an engineering prototype of the hardware.

  12. Low cost attitude control system scanwheel development

    NASA Technical Reports Server (NTRS)

    Bialke, William; Selby, Vaughn

    1991-01-01

    In order to satisfy a growing demand for low cost attitude control systems for small spacecraft, development of low cost scanning horizon sensor coupled to a low cost/low power consumption Reaction Wheel Assembly was initiated. This report addresses the details of the versatile design resulting from this effort. Tradeoff analyses for each of the major components are included, as well as test data from an engineering prototype of the hardware.

  13. Satellite sound broadcasting system, portable reception

    NASA Technical Reports Server (NTRS)

    Golshan, Nasser; Vaisnys, Arvydas

    1990-01-01

    Studies are underway at JPL in the emerging area of Satellite Sound Broadcast Service (SSBS) for direct reception by low cost portable, semi portable, mobile and fixed radio receivers. This paper addresses the portable reception of digital broadcasting of monophonic audio with source material band limited to 5 KHz (source audio comparable to commercial AM broadcasting). The proposed system provides transmission robustness, uniformity of performance over the coverage area and excellent frequency reuse. Propagation problems associated with indoor portable reception are considered in detail and innovative antenna concepts are suggested to mitigate these problems. It is shown that, with the marriage of proper technologies a single medium power satellite can provide substantial direct satellite audio broadcast capability to CONUS in UHF or L Bands, for high quality portable indoor reception by low cost radio receivers.

  14. A low cost, simple, portable instrument for the measurement of infra-red reflectance of paints

    NASA Astrophysics Data System (ADS)

    Marson, F.

    1982-05-01

    The construction and design of a low cost, simple, portable infra-red reflectometer which can be used to estimate the reflectance of paint films in the 800 nm region is described. The infra-red reflectances of a range of lustreless, semigloss and gloss olive drab camouflage paints determined using this instrument are compared to those obtained using modified commercial equipment and to the reflectances measured at 800 nm using a Cary model 17 spectrophotometer. The new reflectometer was shown to be superior to the modified commercial instrument currently specified in Australian government paint specifications and to be capable of estimating the reflectance of olive drab paints to within about one per cent of the Cary derived reflectance values. The reflectance values for a range of 24 experimental coatings made with pigments of varying absorption in the infra-red region are used to illustrate the effect of the instrument's spectral response and the necessity of establishing a reliable working standard.

  15. Analog Front-Ends comparison in the way of a portable, low-power and low-cost EMG controller based on pattern recognition EMBC 2015.

    PubMed

    Mastinu, Enzo; Ortiz-Catalan, Max; Hakansson, Bo

    2015-01-01

    Compact and low-noise Analog Front-Ends (AFEs) are becoming increasingly important for the acquisition of bioelectric signals in portable system. In this work, we compare two popular AFEs available on the market, namely the ADS1299 (Texas Instruments) and the RHA2216 (Intan Technologies). This work develops towards the identification of suitable acquisition modules to design an affordable, reliable and portable device for electromyography (EMG) acquisition and prosthetic control. Device features such as Common Mode Rejection (CMR), Input Referred Noise (IRN) and Signal to Noise Ratio (SNR) were evaluated, as well as the resulting accuracy in myoelectric pattern recognition (MPR) for the decoding of motion intention. Results reported better noise performances and higher MPR accuracy for the ADS1299 and similar SNR values for both devices.

  16. In what ways can low-cost portable monitors best be utilized for health research and patient care in locations that do not have an existing stationary monitoring network?

    EPA Science Inventory

    The presentation provides a short view point in response to the question "In what ways can low-cost portable monitors best be utilized for health research and patient care in locations that do not have an existing stationary monitoring network?" The response notes the ...

  17. Portable and low-cost colorimetric office paper-based device for phenacetin detection in seized cocaine samples.

    PubMed

    da Silva, Gabriela O; de Araujo, William R; Paixão, Thiago R L C

    2018-01-01

    An office paper-based colorimetric device is proposed as a portable, rapid, and low-cost sensor for forensic applications aiming to detect phenacetin used as adulterant in illicit seized materials such as cocaine. The proposed method uses white office paper as the substrate and wax printing technology to fabricate the detection zones. Based on the optimum conditions, a linear analytical curve was obtained for phenacetin concentrations ranging from 0 to 64.52µgmL ‒1 , and the straight line was in accordance with the following equation: (Magenta percentage color) = 1.19 + 0.458 (C Phe /µgmL ‒1 ), R 2 = 0.990. The limit of detection was calculated as 3.5µgmL ‒1 (3σ/slope). The accuracy of the proposed method was evaluated using real seized cocaine samples and the spike-recovery procedure. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. A Portable Low-Power Acquisition System with a Urease Bioelectrochemical Sensor for Potentiometric Detection of Urea Concentrations.

    PubMed

    Ma, Wei-Jhe; Luo, Ching-Hsing; Lin, Jiun-Ling; Chou, Sin-Houng; Chen, Ping-Hung; Syu, Mei-Jywan; Kuo, Shin-Hung; Lai, Shin-Chi

    2016-04-02

    This paper presents a portable low-power battery-driven bioelectrochemical signal acquisition system for urea detection. The proposed design has several advantages, including high performance, low cost, low-power consumption, and high portability. A LT1789-1 low-supply-voltage instrumentation amplifier (IA) was used to measure and amplify the open-circuit potential (OCP) between the working and reference electrodes. An MSP430 micro-controller was programmed to process and transduce the signals to the custom-developed software by ZigBee RF module in wireless mode and UART in able mode. The immobilized urease sensor was prepared by embedding urease into the polymer (aniline-co-o-phenylenediamine) polymeric matrix and then coating/depositing it onto a MEMS-fabricated Au working electrode. The linear correlation established between the urea concentration and the potentiometric change is in the urea concentrations range of 3.16 × 10(-4) to 3.16 × 10(-2) M with a sensitivity of 31.12 mV/log [M] and a precision of 0.995 (R² = 0.995). This portable device not only detects urea concentrations, but can also operate continuously with a 3.7 V rechargeab-le lithium-ion battery (500 mA·h) for at least four days. Accordingly, its use is feasible and even promising for home-care applications.

  19. Small, Low Cost, Launch Capability Development

    NASA Technical Reports Server (NTRS)

    Brown, Thomas

    2014-01-01

    A recent explosion in nano-sat, small-sat, and university class payloads has been driven by low cost electronics and sensors, wide component availability, as well as low cost, miniature computational capability and open source code. Increasing numbers of these very small spacecraft are being launched as secondary payloads, dramatically decreasing costs, and allowing greater access to operations and experimentation using actual space flight systems. While manifesting as a secondary payload provides inexpensive rides to orbit, these arrangements also have certain limitations. Small, secondary payloads are typically included with very limited payload accommodations, supported on a non interference basis (to the prime payload), and are delivered to orbital conditions driven by the primary launch customer. Integration of propulsion systems or other hazardous capabilities will further complicate secondary launch arrangements, and accommodation requirements. The National Aeronautics and Space Administration's Marshall Space Flight Center has begun work on the development of small, low cost launch system concepts that could provide dedicated, affordable launch alternatives to small, high risk university type payloads and spacecraft. These efforts include development of small propulsion systems and highly optimized structural efficiency, utilizing modern advanced manufacturing techniques. This paper outlines the plans and accomplishments of these efforts and investigates opportunities for truly revolutionary reductions in launch and operations costs. Both evolution of existing sounding rocket systems to orbital delivery, and the development of clean sheet, optimized small launch systems are addressed.

  20. Low-cost and highly sensitive immunosensing platform for aflatoxins using one-step competitive displacement reaction mode and portable glucometer-based detection.

    PubMed

    Tang, Dianping; Lin, Youxiu; Zhou, Qian; Lin, Yuping; Li, Peiwu; Niessner, Reinhard; Knopp, Dietmar

    2014-11-18

    Aflatoxins are highly toxic secondary metabolites produced by a number of different fungi and present in a wide range of food and feed commodities. Herein, we designed a simple and low-cost immunosensing platform for highly sensitive detection of mycotoxins (aflatoxin B1, AFB1, used as a model) on polyethylenimine (PEI)-coated mesoporous silica nanocontainers (PEI-MSN). The assay was carried out by using a portable personal glucometer (PGM) as the readout based on a competitive displacement reaction mode between target AFB1 and its pseudo-hapten (PEI-MSN) for monoclonal anti-AFB1 antibody (mAb). To construct such an assay protocol, two nanostructures including mAb-labeled gold nanoparticle (mAb-AuNP) and PEI-MSN were initially synthesized, and then numerous glucose molecules were gated into the pores based on the interaction between negatively charged mAb-AuNP and positively charged PEI-MSN. In the presence of target AFB1, a competitive-type displacement reaction was implemented between mAb-AuNP and PEI-MSN by target AFB1 through the specific antigen-antibody reaction. Accompanying the reaction, target AFB1 could displace the mAb-AuNP from the surface of PEI-MSN, resulting in the release of the loading glucose from the pores due to the gate opened. The released glucose molecules could be quantitatively determined by using a portable PGM. Under optimal conditions, the PGM signal increased with the increment of AFB1 concentration in the range from 0.01 to 15 μg/kg (ppb) with a detection limit (LOD) of 5 ng/kg (5 ppt) at the 3sblank criterion. The selectivity and precision were acceptable. Importantly, the methodology was further validated for assaying naturally contaminated or spiked blank peanut samples, and consistent results between the PGM-based immunoassay and the referenced enzyme-linked immunosorbent assay (ELISA) were obtained. Therefore, the developed immunoassay provides a promising approach for rapid screening of organic pollutants because it is simple

  1. Software for keratometry measurements using portable devices

    NASA Astrophysics Data System (ADS)

    Iyomasa, C. M.; Ventura, L.; De Groote, J. J.

    2010-02-01

    In this work we present an image processing software for automatic astigmatism measurements developed for a hand held keratometer. The system projects 36 light spots, from LEDs, displayed in a precise circle at the lachrymal film of the examined cornea. The displacement, the size and deformation of the reflected image of these light spots are analyzed providing the keratometry. The purpose of this research is to develop a software that performs fast and precise calculations in mainstream mobile devices. In another words, a software that can be implemented in portable computer systems, which could be of low cost and easy to handle. This project allows portability for keratometers and is a previous work for a portable corneal topographer.

  2. [Hemodynamics studies with the new generation portable systems: cost-benefit analysis].

    PubMed

    Vergara, G

    2001-01-01

    Coronary angiography facilities are usually available only in major medical centers despite an increasing utilization in managing patients with ischemic heart disease. In recent years portable fluoroscopic imaging systems have been developed to reduce costs and bring coronary angiography services closer to patients. Our experience with the OEC Medical System 9600 demonstrates that the portable systems of new generation are reliable both regarding the quality of coronary angiograms and the routine use in a multipurpose cardiac catheterization laboratory. This statement is based on our 1-year experience (1999) with a caseload of 740 studies or procedures: 342 coronary angiographic studies, 159 electrophysiological studies, 74 radiofrequency catheter ablations, 126 pacemaker implantations/replacements, 16 cardioverter-defibrillator implantations/replacements, and 23 other studies or procedures. The mean cost of a coronary angiography was Itl 512,000 (265 Euro) in the in-house laboratory; it would have been Itl 694,000 (359 Euro) in the historical scenario, i.e. with referral to a 25 km distant laboratory, with Itl 182,000 (94 Euro) saved. Our experience is consistent with the accepted criteria of good laboratory performance and cost-effectiveness.

  3. a Low-Cost and Portable System for 3d Reconstruction of Texture-Less Objects

    NASA Astrophysics Data System (ADS)

    Hosseininaveh, A.; Yazdan, R.; Karami, A.; Moradi, M.; Ghorbani, F.

    2015-12-01

    The optical methods for 3D modelling of objects can be classified into two categories including image-based and range-based methods. Structure from Motion is one of the image-based methods implemented in commercial software. In this paper, a low-cost and portable system for 3D modelling of texture-less objects is proposed. This system includes a rotating table designed and developed by using a stepper motor and a very light rotation plate. The system also has eight laser light sources with very dense and strong beams which provide a relatively appropriate pattern on texture-less objects. In this system, regarding to the step of stepper motor, images are semi automatically taken by a camera. The images can be used in structure from motion procedures implemented in Agisoft software.To evaluate the performance of the system, two dark objects were used. The point clouds of these objects were obtained by spraying a light powders on the objects and exploiting a GOM laser scanner. Then these objects were placed on the proposed turntable. Several convergent images were taken from each object while the laser light sources were projecting the pattern on the objects. Afterward, the images were imported in VisualSFM as a fully automatic software package for generating an accurate and complete point cloud. Finally, the obtained point clouds were compared to the point clouds generated by the GOM laser scanner. The results showed the ability of the proposed system to produce a complete 3D model from texture-less objects.

  4. A low-cost, portable, laser heterodyne radiometer for validating passive satellite observations of column carbon dioxide and methane

    NASA Astrophysics Data System (ADS)

    Wilson, E. L.; DiGregorio, A.; Villanueva, G. L.; Miletti, K.; Grunberg, C.; Grunberg, M.; Floyd, M.; Menendez, A. R.

    2017-12-01

    We present a low-cost, portable, miniaturized, laser heterodyne radiometer (mini-LHR) capable of measuring column carbon dioxide (CO2) and methane (CH4) in remote locations to validate passive satellite observations. A benefit of the portability is that mini-LHR instruments can be calibrated and compared site-by-side to quantify any internal biases, or any biases in stationary column instruments such as those in the total carbon column observing network (TCCON). This is the latest iteration of an instrument that has been under development by our team since 2009. During our recent Interdisciplinary Science (IDS) effort that involved measuring carbon emissions over thawing permafrost, it became clear that our mini-LHR needed to be redesigned to be significantly smaller, lighter, and to operate from a small solar panel so that it could be easily carried to the field sites located within the Bonanza Creek Research Forest near Fairbanks, AK. The boreal peatland sites at Bonanza Creek have forests that are underlain by cold soils, permafrost, collapse scar thermokarst bogs resulting from permafrost thaw, and rich fens with various underlying sediments and gravels that are not frozen. While these sites are extremely interesting for their role in carbon storage, the practical issue with these sites is that they are very wet (the fen site for example is periodically under several inches of water) and the trails to reach these sites are extremely muddy, narrow, and populated with swarms of biting insects. The soils at these sites are delicate and easily damaged by excessive foot traffic. They are also prone to periodic wild fires - making permanent column instrument installations impractical. Here, we compare data from the permafrost field work as well as data collected as part of the Hawai'i Space Exploration Analog and Simulation (Hi-SEAS) project where crewmembers are currently testing the mini-LHR on an isolated Mars-like site on the Mauna Loa side of the saddle area on

  5. The low cost Proton Precession Magnetometer developed at the Indian Institute of Geomagnetism

    NASA Astrophysics Data System (ADS)

    Mahavarkar, P.; Singh, S.; Labde, S.; Dongre, V.; Patil, A.

    2017-05-01

    Proton magnetometers are the oldest scalar magnetometers. The first commercial units were produced in early 1960s as portable instruments. In continuation airborne instruments appeared with optimized speed of readings and sensitivity, large sensors etc. Later development of Overhauser and optically pumped magnetometers has eliminated Proton magnetometers from airborne surveys. However they remain very popular in various ground surveys and observatories. With this primary purpose of generating the ground based magnetic data, the Indian Institute of Geomagnetism (IIG) for the last 3 decades have been developing low cost Proton Precession Magnetometers (PPM). Beginning with the 1 nT PPM which has undergone several changes in design, the successor PM7 the advanced version has been successfully developed by the institute and is installed at various observatories of the institute. PM7 records the total field `F' with accuracy of 0.1 nT and a sampling rate of 10 seconds/sample. This article briefly discusses the design and development of this IIG make PM7 and compares the data recorded by this instrument with one of the commercially available Overhauser magnetometer in the world market. The quality of data recorded by PM7 is in excellent agreement with the Overhauser. With the available quality of data generated by this instrument, PM7 is an affordable PPM for scientific institutions, schools and colleges intending to carry out geomagnetic studies. The commercial cost of PM7 is ≈ 20% of the cost of Overhauser available in market.

  6. Low-cost uncooled VOx infrared camera development

    NASA Astrophysics Data System (ADS)

    Li, Chuan; Han, C. J.; Skidmore, George D.; Cook, Grady; Kubala, Kenny; Bates, Robert; Temple, Dorota; Lannon, John; Hilton, Allan; Glukh, Konstantin; Hardy, Busbee

    2013-06-01

    The DRS Tamarisk® 320 camera, introduced in 2011, is a low cost commercial camera based on the 17 µm pixel pitch 320×240 VOx microbolometer technology. A higher resolution 17 µm pixel pitch 640×480 Tamarisk®640 has also been developed and is now in production serving the commercial markets. Recently, under the DARPA sponsored Low Cost Thermal Imager-Manufacturing (LCTI-M) program and internal project, DRS is leading a team of industrial experts from FiveFocal, RTI International and MEMSCAP to develop a small form factor uncooled infrared camera for the military and commercial markets. The objective of the DARPA LCTI-M program is to develop a low SWaP camera (<3.5 cm3 in volume and <500 mW in power consumption) that costs less than US $500 based on a 10,000 units per month production rate. To meet this challenge, DRS is developing several innovative technologies including a small pixel pitch 640×512 VOx uncooled detector, an advanced digital ROIC and low power miniature camera electronics. In addition, DRS and its partners are developing innovative manufacturing processes to reduce production cycle time and costs including wafer scale optic and vacuum packaging manufacturing and a 3-dimensional integrated camera assembly. This paper provides an overview of the DRS Tamarisk® project and LCTI-M related uncooled technology development activities. Highlights of recent progress and challenges will also be discussed. It should be noted that BAE Systems and Raytheon Vision Systems are also participants of the DARPA LCTI-M program.

  7. A Portable Low-Power Acquisition System with a Urease Bioelectrochemical Sensor for Potentiometric Detection of Urea Concentrations

    PubMed Central

    Ma, Wei-Jhe; Luo, Ching-Hsing; Lin, Jiun-Ling; Chou, Sin-Houng; Chen, Ping-Hung; Syu, Mei-Jywan; Kuo, Shin-Hung; Lai, Shin-Chi

    2016-01-01

    This paper presents a portable low-power battery-driven bioelectrochemical signal acquisition system for urea detection. The proposed design has several advantages, including high performance, low cost, low-power consumption, and high portability. A LT1789-1 low-supply-voltage instrumentation amplifier (IA) was used to measure and amplify the open-circuit potential (OCP) between the working and reference electrodes. An MSP430 micro-controller was programmed to process and transduce the signals to the custom-developed software by ZigBee RF module in wireless mode and UART in able mode. The immobilized urease sensor was prepared by embedding urease into the polymer (aniline-co-o-phenylenediamine) polymeric matrix and then coating/depositing it onto a MEMS-fabricated Au working electrode. The linear correlation established between the urea concentration and the potentiometric change is in the urea concentrations range of 3.16 × 10−4 to 3.16 × 10−2 M with a sensitivity of 31.12 mV/log [M] and a precision of 0.995 (R2 = 0.995). This portable device not only detects urea concentrations, but can also operate continuously with a 3.7 V rechargeab-le lithium-ion battery (500 mA·h) for at least four days. Accordingly, its use is feasible and even promising for home-care applications. PMID:27049390

  8. Low cost attitude control system reaction wheel development

    NASA Astrophysics Data System (ADS)

    Bialke, William

    1991-03-01

    In order to satisfy a growing demand for low cost attitude control systems for small spacecraft, development of a low power and low cost Reaction Wheel Assembly was initiated. The details of the versatile design resulting from this effort are addressed. Tradeoff analyses for each of the major components are included, as well as test data from an engineering prototype of the hardware.

  9. Low cost attitude control system reaction wheel development

    NASA Technical Reports Server (NTRS)

    Bialke, William

    1991-01-01

    In order to satisfy a growing demand for low cost attitude control systems for small spacecraft, development of a low power and low cost Reaction Wheel Assembly was initiated. The details of the versatile design resulting from this effort are addressed. Tradeoff analyses for each of the major components are included, as well as test data from an engineering prototype of the hardware.

  10. Center for Global Health announces grants to support portable technologies

    Cancer.gov

    NCI's Center for Global Health announced grants that will support the development and validation of low-cost, portable technologies. These technologies have the potential to improve early detection, diagnosis, and non-invasive or minimally invasive treatm

  11. Development of low cost custom hybrid microcircuit technology

    NASA Technical Reports Server (NTRS)

    Perkins, K. L.; Licari, J. J.

    1981-01-01

    Selected potentially low cost, alternate packaging and interconnection techniques were developed and implemented in the manufacture of specific NASA/MSFC hardware, and the actual cost savings achieved by their use. The hardware chosen as the test bed for this evaluation ws the hybrids and modules manufactured by Rockwell International fo the MSFC Flight Accelerometer Safety Cut-Off System (FASCOS). Three potentially low cost packaging and interconnection alternates were selected for evaluation. This study was performed in three phases: hardware fabrication and testing, cost comparison, and reliability evaluation.

  12. [Development of a portable ambulatory ECG monitor based on embedded microprocessor unit].

    PubMed

    Wang, Da-xiong; Wang, Guo-jun

    2005-06-01

    To develop a new kind of portable ambulatory ECG monitor. The hardware and software were designed based on RCA-CDP1802. New methods of ECG data compression and feature extraction of QRS complexes were applied to software design. A model for automatic arrhythmia analysis was established for real-time ambulatory ECG Data analysis. Compact, low power consumption and low cost were emphasized in the hardware design. This compact and light-weight monitor with low power consumption and high intelligence was capable of real-time monitoring arrhythmia for more than 48 h. More than ten types of arrhythmia could be detected, only the compressed abnormal ECG data was recorded and could be transmitted to the host if required. The monitor meets the design requirements and can be used for ambulatory ECG monitoring.

  13. Development of a heavy duty portable variable power supply (HPVPS)

    NASA Astrophysics Data System (ADS)

    Musa, Ahmad Zulfadli Bin; Lung, Chong Man; Abidin, Wan'Amirah Basyarah Binti Zainol

    2017-08-01

    This paper covers the innovation of a Heavy Duty Portable Variable Power Supply (HPVPS) in Jabatan Kejuruteraan Elektrik (JKE), Politeknik Mukah, Sarawak (PMU). This project consists of variable power supply which can vary the output from 1.2 V to 11.6V, AC pure wave inverter to convert DC to AC for the operation of low power home appliances and also used Li-on rechargeable batteries to store the electrical energy and additional feature that can be used to jump-start the batteries of the car. The main objective of this project is to make the user can operate the electronic devices anywhere whenever if no electricity while doing their lab activities. Most of the regulated power supply in JKE lab aged 9-10 years old and need periodical maintenance and need cost and also the unit can be used is not enough to support the whole class during lab activities. As a result, the P&P process will be facing the major problem in order to make the lab activities running smoothly. By development of the portable variable power supply, the P&P process is more efficient and very helpful.

  14. Sweat Sodium Concentration: Inter-Unit Variability of a Low Cost, Portable, and Battery Operated Sodium Analyzer.

    PubMed

    Goulet, Eric D B; Baker, Lindsay B

    2017-12-01

    The B-722 Laqua Twin is a low cost, portable, and battery operated sodium analyzer, which can be used for the assessment of sweat sodium concentration. The Laqua Twin is reliable and provides a degree of accuracy similar to more expensive analyzers; however, its interunit measurement error remains unknown. The purpose of this study was to compare the sodium concentration values of 70 sweat samples measured using three different Laqua Twin units. Mean absolute errors, random errors and constant errors among the different Laqua Twins ranged respectively between 1.7 mmol/L to 3.5 mmol/L, 2.5 mmol/L to 3.7 mmol/L and -0.6 mmol/L to 3.9 mmol/L. Proportional errors among Laqua Twins were all < 2%. Based on a within-subject biological variability in sweat sodium concentration of ± 12%, the maximal allowable imprecision among instruments was considered to be £ 6%. In that respect, the within (2.9%), between (4.5%), and total (5.4%) measurement error coefficient of variations were all < 6%. For a given sweat sodium concentration value, the largest observed difference in mean and lower and upper bound error of measurements among instruments were, respectively, 4.7 mmol/L, 2.3 mmol/L, and 7.0 mmol/L. In conclusion, our findings show that the interunit measurement error of the B-722 Laqua Twin is low and methodologically acceptable.

  15. A portable, low-cost flight-data measurement and recording system

    NASA Technical Reports Server (NTRS)

    Miller, R. J.

    1982-01-01

    The design of and the experience with an inexpensive, hand-portable, onboard data system used to record four parameters in the final portion of the landing approach and touchdown of an airplane are described. The system utilized a high-quality audio tape recorder and amateur photographic equipment with accessory circuitry rather than specialized instrumentation to given satisfactory results.

  16. 47 CFR 52.33 - Recovery of carrier-specific costs directly related to providing long-term number portability.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... Recovery of carrier-specific costs directly related to providing long-term number portability. (a... related to providing long-term number portability. 52.33 Section 52.33 Telecommunication FEDERAL... long-term number portability by establishing in tariffs filed with the Federal Communications...

  17. 47 CFR 52.33 - Recovery of carrier-specific costs directly related to providing long-term number portability.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... Recovery of carrier-specific costs directly related to providing long-term number portability. (a... related to providing long-term number portability. 52.33 Section 52.33 Telecommunication FEDERAL... long-term number portability by establishing in tariffs filed with the Federal Communications...

  18. 47 CFR 52.33 - Recovery of carrier-specific costs directly related to providing long-term number portability.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... Recovery of carrier-specific costs directly related to providing long-term number portability. (a... related to providing long-term number portability. 52.33 Section 52.33 Telecommunication FEDERAL... long-term number portability by establishing in tariffs filed with the Federal Communications...

  19. 47 CFR 52.33 - Recovery of carrier-specific costs directly related to providing long-term number portability.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... Recovery of carrier-specific costs directly related to providing long-term number portability. (a... related to providing long-term number portability. 52.33 Section 52.33 Telecommunication FEDERAL... long-term number portability by establishing in tariffs filed with the Federal Communications...

  20. Low-cost computer mouse for the elderly or disabled in Taiwan.

    PubMed

    Chen, C-C; Chen, W-L; Chen, B-N; Shih, Y-Y; Lai, J-S; Chen, Y-L

    2014-01-01

    A mouse is an important communication interface between a human and a computer, but it is still difficult to use for the elderly or disabled. To develop a low-cost computer mouse auxiliary tool. The principal structure of the low-cost mouse auxiliary tool is the IR (infrared ray) array module and the Wii icon sensor module, which combine with reflective tape and the SQL Server database. This has several benefits including cheap hardware cost, fluent control, prompt response, adaptive adjustment and portability. Also, it carries the game module with the function of training and evaluation; to the trainee, it is really helpful to upgrade the sensitivity of consciousness/sense and the centralization of attention. The intervention phase/maintenance phase, with regard to clicking accuracy and use of time, p value (p< 0.05) reach the level of significance. The development of the low cost adaptive computer mouse auxiliary tool was completed during the study and was also verified as having the characteristics of low cost, easy operation and the adaptability. To patients with physical disabilities, if they have independent control action parts of their limbs, the mouse auxiliary tool is suitable for them to use, i.e. the user only needs to paste the reflective tape by the independent control action parts of the body to operate the mouse auxiliary tool.

  1. Design and development of a low-cost biphasic charge-balanced functional electric stimulator and its clinical validation.

    PubMed

    Shendkar, Chandrashekhar; Lenka, Prasanna K; Biswas, Abhishek; Kumar, Ratnesh; Mahadevappa, Manjunatha

    2015-10-01

    Functional electric stimulators that produce near-ideal, charge-balanced biphasic stimulation waveforms with interphase delay are considered safer and more efficacious than conventional stimulators. An indigenously designed, low-cost, portable FES device named InStim is developed. It features a charge-balanced biphasic single channel. The authors present the complete design, mathematical analysis of the circuit and the clinical evaluation of the device. The developed circuit was tested on stroke patients affected by foot drop problems. It was tested both under laboratory conditions and in clinical settings. The key building blocks of this circuit are low dropout regulators, a DC-DC voltage booster and a single high-power current source OP-Amp with current-limiting capabilities. This allows the device to deliver high-voltage, constant current, biphasic pulses without the use of a bulky step-up transformer. The advantages of the proposed design over the currently existing devices include improved safety features (zero DC current, current-limiting mechanism and safe pulses), waveform morphology that causes less muscle fatigue, cost-effectiveness and compact power-efficient circuit design with minimal components. The device is also capable of producing appropriate ankle dorsiflexion in patients having foot drop problems of various Medical Research Council scale grades.

  2. Long life, low cost, rechargeable AgZn battery for non-military applications

    NASA Astrophysics Data System (ADS)

    Brown, Curtis C.

    1996-03-01

    Of the rechargeable (secondary) battery systems with mature technology, the silver oxide-zinc system (AgZn) safely offers the highest power and energy (watts and watt hours) per unit of volume and mass. As a result they have long been used for aerospace and defense applications where they have also proven their high reliability. In the past, the expense associated with the cost of silver and the resulting low production volume have limited their commercial application. However, the relative low cost of silver now make this system feasible in many applications where high energy and reliability are required. One area of commercial potential is power for a new generation of sophisticated, portable medical equipment. AgZn batteries have recently proven ``enabling technology'' for power critical, advanced medical devices. By extending the cycle calendar life to the system (offers both improved performance and lower operating cost), a combination is achieved which may enable a wide range of future electrical devices. Other areas where AgZn batteries have been used in nonmilitary applications to provide power to aid in the development of commercial equipment have been: (a) Electrically powered vehicles; (b) Remote sensing in nuclear facilities; (c) Special effects equipment for movies; (d) Remote sensing in petroleum pipe lines; (e) Portable computers; (f) Fly by wire systems for commercial aircraft; and (g) Robotics. However none of these applications have progressed to the level where the volume required will significantly lower cost.

  3. Discharge of thoracic patients on portable digital suction: Is it cost-effective?

    PubMed

    Southey, Dawn; Pullinger, Diane; Loggos, Spiros; Kumari, Nelam; Lengyel, Emma; Morgan, Ian; Yiu, Patrick; Nandi, Jayanta; Luckraz, Heyman

    2015-09-01

    A portable suction drainage device for patients undergoing thoracic surgical procedures was introduced into our service in January 2010. Patients who met strict discharge criteria were allowed to continue their treatment at home with the device. They were monitored in a designated follow-up clinic. Data were collected to identify the impact of this service in relation to the duration of follow-up required, bed-days saved, and potential cost/benefits. All patients who underwent a thoracic procedure from March 2012 to April 2014 and required suction postoperatively for air leak were included in the study. Patients were identified as suitable according to the discharge criteria. Data regarding patient demographics were collected prospectively on the thoracic database, and data on the drainage device were logged in a specific data sheet. Visits to the follow-up clinic were also recorded. During the study period, 50 patients stayed a total 1125 days on the portable suction system. Twenty were discharged home, equating to 772 bed-days saved (GBP 270,000 cost-saving). Clinic attendance totalled 162 visits (GBP 24,300 cost reimbursement for attendance). Six (30%) patients were readmitted on 9 occasions due to device malfunction or inability to cope at home. Careful identification of patients suitable for discharge with a portable suction device achieved a significant cost-saving and freed hospital beds, thus allowing increased surgical activity. Patients were also able to be cared for within their home environment and maintain their quality of life. © The Author(s) 2015.

  4. High-pressure portable pneumatic drive unit.

    PubMed

    Hete, B F; Savage, M; Batur, C; Smith, W A; Golding, L A; Nosé, Y

    1989-12-01

    The left ventricular assist device (LVAD) of the Cleveland Clinic Foundation (CCF) is a single-chamber assist pump, driven by a high-pressure pneumatic cylinder. A low-cost, portable driver that will allow cardiac care patients, with a high-pressure pneumatic ventricle assist, more freedom of movement has been developed. The compact and light-weight configuration can provide periods of 2 h of freedom from a fixed position driver and does not use exotic technology.

  5. A low-cost, portable, high-throughput wireless sensor system for phonocardiography applications.

    PubMed

    Sa-Ngasoongsong, Akkarapol; Kunthong, Jakkrit; Sarangan, Venkatesh; Cai, Xinwei; Bukkapatnam, Satish T S

    2012-01-01

    This paper presents the design and testing of a wireless sensor system developed using a Microchip PICDEM developer kit to acquire and monitor human heart sounds for phonocardiography applications. This system can serve as a cost-effective option to the recent developments in wireless phonocardiography sensors that have primarily focused on Bluetooth technology. This wireless sensor system has been designed and developed in-house using off-the-shelf components and open source software for remote and mobile applications. The small form factor (3.75 cm × 5 cm × 1 cm), high throughput (6,000 Hz data streaming rate), and low cost ($13 per unit for a 1,000 unit batch) of this wireless sensor system make it particularly attractive for phonocardiography and other sensing applications. The experimental results of sensor signal analysis using several signal characterization techniques suggest that this wireless sensor system can capture both fundamental heart sounds (S1 and S2), and is also capable of capturing abnormal heart sounds (S3 and S4) and heart murmurs without aliasing. The results of a denoising application using Wavelet Transform show that the undesirable noises of sensor signals in the surrounding environment can be reduced dramatically. The exercising experiment results also show that this proposed wireless PCG system can capture heart sounds over different heart conditions simulated by varying heart rates of six subjects over a range of 60-180 Hz through exercise testing.

  6. A Low-Cost, Portable, High-Throughput Wireless Sensor System for Phonocardiography Applications

    PubMed Central

    Sa-ngasoongsong, Akkarapol; Kunthong, Jakkrit; Sarangan, Venkatesh; Cai, Xinwei; Bukkapatnam, Satish T. S.

    2012-01-01

    This paper presents the design and testing of a wireless sensor system developed using a Microchip PICDEM developer kit to acquire and monitor human heart sounds for phonocardiography applications. This system can serve as a cost-effective option to the recent developments in wireless phonocardiography sensors that have primarily focused on Bluetooth technology. This wireless sensor system has been designed and developed in-house using off-the-shelf components and open source software for remote and mobile applications. The small form factor (3.75 cm × 5 cm × 1 cm), high throughput (6,000 Hz data streaming rate), and low cost ($13 per unit for a 1,000 unit batch) of this wireless sensor system make it particularly attractive for phonocardiography and other sensing applications. The experimental results of sensor signal analysis using several signal characterization techniques suggest that this wireless sensor system can capture both fundamental heart sounds (S1 and S2), and is also capable of capturing abnormal heart sounds (S3 and S4) and heart murmurs without aliasing. The results of a denoising application using Wavelet Transform show that the undesirable noises of sensor signals in the surrounding environment can be reduced dramatically. The exercising experiment results also show that this proposed wireless PCG system can capture heart sounds over different heart conditions simulated by varying heart rates of six subjects over a range of 60–180 Hz through exercise testing. PMID:23112633

  7. Development of a Novel, Low-Cost, Disposable Wooden Pencil Graphite Electrode for Use in the Determination of Antioxidants and Other Biological Compounds.

    PubMed

    Kariuki, James; Ervin, Emily; Olafson, Carly

    2015-07-31

    The development of portable sensors that can be used outside the lab is an active area of research in the electroanalytical field. A major focus of such research is the development of low-cost electrodes for use in these sensors. Current electrodes, such as glassy-carbon electrodes (GCEs), are costly and require time-consuming preparation. Alternatives have been proposed, including mechanical pencil-lead electrodes (MPEs). However, MPEs themselves possess numerous drawbacks, particularly structural fragility. In this paper, we present a novel pencil-graphite electrode (PGE) fabricated from a regular HB#2 pencil. This PGE is a simple, disposable, extremely low-cost alternative to GCEs ($0.30 per PGE, vs. $190 + per GCE), and possesses the structural stability that MPEs lack. PGEs were characterized by square-wave voltammetry of ferricyanide, gallic acid, uric acid, dopamine, and several foodstuffs. In all cases, PGEs demonstrated sensitivities comparable or superior to those of the GCE and MPE (LOD = 5.62 × 10(-4) M PGE, 4.80 × 10(-4) M GCE, 2.93 × 10(-4) M MPE). Signal areas and peak heights were typically four to ten times larger for the PGE relative to the GCE.

  8. Methodology for cost analysis of film-based and filmless portable chest systems

    NASA Astrophysics Data System (ADS)

    Melson, David L.; Gauvain, Karen M.; Beardslee, Brian M.; Kraitsik, Michael J.; Burton, Larry; Blaine, G. James; Brink, Gary S.

    1996-05-01

    Many studies analyzing the costs of film-based and filmless radiology have focused on multi- modality, hospital-wide solutions. Yet due to the enormous cost of converting an entire large radiology department or hospital to a filmless environment all at once, institutions often choose to eliminate film one area at a time. Narrowing the focus of cost-analysis may be useful in making such decisions. This presentation will outline a methodology for analyzing the cost per exam of film-based and filmless solutions for providing portable chest exams to Intensive Care Units (ICUs). The methodology, unlike most in the literature, is based on parallel data collection from existing filmless and film-based ICUs, and is currently being utilized at our institution. Direct costs, taken from the perspective of the hospital, for portable computed radiography chest exams in one filmless and two film-based ICUs are identified. The major cost components are labor, equipment, materials, and storage. Methods for gathering and analyzing each of the cost components are discussed, including FTE-based and time-based labor analysis, incorporation of equipment depreciation, lease, and maintenance costs, and estimation of materials costs. Extrapolation of data from three ICUs to model hypothetical, hospital-wide film-based and filmless ICU imaging systems is described. Performance of sensitivity analysis on the filmless model to assess the impact of anticipated reductions in specific labor, equipment, and archiving costs is detailed. A number of indirect costs, which are not explicitly included in the analysis, are identified and discussed.

  9. Self-powered integrated microfluidic point-of-care low-cost enabling (SIMPLE) chip

    PubMed Central

    Yeh, Erh-Chia; Fu, Chi-Cheng; Hu, Lucy; Thakur, Rohan; Feng, Jeffrey; Lee, Luke P.

    2017-01-01

    Portable, low-cost, and quantitative nucleic acid detection is desirable for point-of-care diagnostics; however, current polymerase chain reaction testing often requires time-consuming multiple steps and costly equipment. We report an integrated microfluidic diagnostic device capable of on-site quantitative nucleic acid detection directly from the blood without separate sample preparation steps. First, we prepatterned the amplification initiator [magnesium acetate (MgOAc)] on the chip to enable digital nucleic acid amplification. Second, a simplified sample preparation step is demonstrated, where the plasma is separated autonomously into 224 microwells (100 nl per well) without any hemolysis. Furthermore, self-powered microfluidic pumping without any external pumps, controllers, or power sources is accomplished by an integrated vacuum battery on the chip. This simple chip allows rapid quantitative digital nucleic acid detection directly from human blood samples (10 to 105 copies of methicillin-resistant Staphylococcus aureus DNA per microliter, ~30 min, via isothermal recombinase polymerase amplification). These autonomous, portable, lab-on-chip technologies provide promising foundations for future low-cost molecular diagnostic assays. PMID:28345028

  10. Portable Virtual Training Units

    NASA Technical Reports Server (NTRS)

    Malone, Reagan; Johnston, Alan

    2015-01-01

    The Mission Operations Lab initiated a project to design, develop, deliver, test, and validate a unique training system for astronaut and ground support personnel. In an effort to keep training costs low, virtual training units (VTUs) have been designed based on images of actual hardware and manipulated by a touch screen style interface for ground support personnel training. This project helped modernized the training system and materials by integrating them with mobile devices for training when operators or crew are unavailable to physically train in the facility. This project also tested the concept of a handheld remote device to control integrated trainers using International Space Station (ISS) training simulators as a platform. The portable VTU can interface with the full-sized VTU, allowing a trainer co-located with a trainee to remotely manipulate a VTU and evaluate a trainee's response. This project helped determine if it is useful, cost effective, and beneficial for the instructor to have a portable handheld device to control the behavior of the models during training. This project has advanced NASA Marshall Space Flight Center's (MSFC's) VTU capabilities with modern and relevant technology to support space flight training needs of today and tomorrow.

  11. Preliminary study of Low-Cost Micro Gas Turbine

    NASA Astrophysics Data System (ADS)

    Fikri, M.; Ridzuan, M.; Salleh, Hamidon

    2016-11-01

    The electricity consumption nowadays has increased due to the increasing development of portable electronic devices. The development of low cost micro gas turbine engine, which is designed for the purposes of new electrical generation Micro turbines are a relatively new distributed generation technology being used for stationary energy generation applications. They are a type of combustion turbine that produces both heat and electricity on a relatively small scaled.. This research are focusing of developing a low-cost micro gas turbine engine based on automotive turbocharger and to evaluation the performance of the developed micro gas turbine. The test rig engine basically was constructed using a Nissan 45V3 automotive turbocharger, containing compressor and turbine assemblies on a common shaft. The operating performance of developed micro gas turbine was analyzed experimentally with the increment of 5000 RPM on the compressor speed. The speed of the compressor was limited at 70000 RPM and only 1000 degree Celsius at maximum were allowed to operate the system in order to avoid any failure on the turbocharger bearing and the other components. Performance parameters such as inlet temperature, compressor temperature, exhaust gas temperature, and fuel and air flow rates were measured. The data was collected electronically by 74972A data acquisition and evaluated manually by calculation. From the independent test shows the result of the system, The speed of the LP turbine can be reached up to 35000 RPM and produced 18.5kw of mechanical power.

  12. Application of low-cost methodologies for mobile phone app development.

    PubMed

    Zhang, Melvyn; Cheow, Enquan; Ho, Cyrus Sh; Ng, Beng Yeong; Ho, Roger; Cheok, Christopher Cheng Soon

    2014-12-09

    The usage of mobile phones and mobile phone apps in the recent decade has indeed become more prevalent. Previous research has highlighted a method of using just the Internet browser and a text editor to create an app, but this does not eliminate the challenges faced by clinicians. More recently, two methodologies of app development have been shared, but there has not been any disclosures pertaining to the costs involved. In addition, limitations such as the distribution and dissemination of the apps have not been addressed. The aims of this research article are to: (1) highlight a low-cost methodology that clinicians without technical knowledge could use to develop educational apps; (2) clarify the respective costs involved in the process of development; (3) illustrate how limitations pertaining to dissemination could be addressed; and (4) to report initial utilization data of the apps and to share initial users' self-rated perception of the apps. In this study, we will present two techniques of how to create a mobile app using two of the well-established online mobile app building websites. The costs of development are specified and the methodology of dissemination of the apps will be shared. The application of the low-cost methodologies in the creation of the "Mastering Psychiatry" app for undergraduates and "Déjà vu" app for postgraduates will be discussed. A questionnaire survey has been administered to undergraduate students collating their perceptions towards the app. For the Mastering Psychiatry app, a cumulative total of 722 users have used the mobile app since inception, based on our analytics. For the Déjà vu app, there has been a cumulative total of 154 downloads since inception. The utilization data demonstrated the receptiveness towards these apps, and this is reinforced by the positive perceptions undergraduate students (n=185) had towards the low-cost self-developed apps. This is one of the few studies that have demonstrated the low-cost

  13. Application of Low-Cost Methodologies for Mobile Phone App Development

    PubMed Central

    Ng, Beng Yeong; Ho, Roger; Cheok, Christopher Cheng Soon

    2014-01-01

    Background The usage of mobile phones and mobile phone apps in the recent decade has indeed become more prevalent. Previous research has highlighted a method of using just the Internet browser and a text editor to create an app, but this does not eliminate the challenges faced by clinicians. More recently, two methodologies of app development have been shared, but there has not been any disclosures pertaining to the costs involved. In addition, limitations such as the distribution and dissemination of the apps have not been addressed. Objective The aims of this research article are to: (1) highlight a low-cost methodology that clinicians without technical knowledge could use to develop educational apps; (2) clarify the respective costs involved in the process of development; (3) illustrate how limitations pertaining to dissemination could be addressed; and (4) to report initial utilization data of the apps and to share initial users’ self-rated perception of the apps. Methods In this study, we will present two techniques of how to create a mobile app using two of the well-established online mobile app building websites. The costs of development are specified and the methodology of dissemination of the apps will be shared. The application of the low-cost methodologies in the creation of the “Mastering Psychiatry” app for undergraduates and “Déjà vu” app for postgraduates will be discussed. A questionnaire survey has been administered to undergraduate students collating their perceptions towards the app. Results For the Mastering Psychiatry app, a cumulative total of 722 users have used the mobile app since inception, based on our analytics. For the Déjà vu app, there has been a cumulative total of 154 downloads since inception. The utilization data demonstrated the receptiveness towards these apps, and this is reinforced by the positive perceptions undergraduate students (n=185) had towards the low-cost self-developed apps. Conclusions This is one of

  14. A Rapid and Low-Cost PCR Thermal Cycler for Low Resource Settings.

    PubMed

    Wong, Grace; Wong, Isaac; Chan, Kamfai; Hsieh, Yicheng; Wong, Season

    2015-01-01

    Many modern molecular diagnostic assays targeting nucleic acids are typically confined to developed countries or to the national reference laboratories of developing-world countries. The ability to make technologies for the rapid diagnosis of infectious diseases broadly available in a portable, low-cost format would mark a revolutionary step forward in global health. Many molecular assays are also developed based on polymerase chain reactions (PCR), which require thermal cyclers that are relatively heavy (>20 pounds) and need continuous electrical power. The temperature ramping speed of most economical thermal cyclers are relatively slow (2 to 3 °C/s) so a polymerase chain reaction can take 1 to 2 hours. Most of all, these thermal cyclers are still too expensive ($2k to $4k) for low-resource setting uses. In this article, we demonstrate the development of a low-cost and rapid water bath based thermal cycler that does not require active temperature control or continuous power supply during PCR. This unit costs $130 to build using commercial off-the-shelf items. The use of two or three vacuum-insulated stainless-steel Thermos food jars containing heated water (for denaturation and annealing/extension steps) and a layer of oil on top of the water allow for significantly stabilized temperatures for PCR to take place. Using an Arduino-based microcontroller, we automate the "archaic" method of hand-transferring PCR tubes between water baths. We demonstrate that this innovative unit can deliver high speed PCR (17 s per PCR cycle) with the potential to go beyond the 1,522 bp long amplicons tested in this study and can amplify from templates down to at least 20 copies per reaction. The unit also accepts regular PCR tubes and glass capillary tubes. The PCR efficiency of our thermal cycler is not different from other commercial thermal cyclers. When combined with a rapid nucleic acid detection approach, the thermos thermal cycler (TTC) can enable on-site molecular

  15. A Rapid and Low-Cost PCR Thermal Cycler for Low Resource Settings

    PubMed Central

    Wong, Grace; Wong, Isaac; Chan, Kamfai; Hsieh, Yicheng; Wong, Season

    2015-01-01

    Background Many modern molecular diagnostic assays targeting nucleic acids are typically confined to developed countries or to the national reference laboratories of developing-world countries. The ability to make technologies for the rapid diagnosis of infectious diseases broadly available in a portable, low-cost format would mark a revolutionary step forward in global health. Many molecular assays are also developed based on polymerase chain reactions (PCR), which require thermal cyclers that are relatively heavy (>20 pounds) and need continuous electrical power. The temperature ramping speed of most economical thermal cyclers are relatively slow (2 to 3°C/s) so a polymerase chain reaction can take 1 to 2 hours. Most of all, these thermal cyclers are still too expensive ($2k to $4k) for low-resource setting uses. Methodology/Principal Findings In this article, we demonstrate the development of a low-cost and rapid water bath based thermal cycler that does not require active temperature control or continuous power supply during PCR. This unit costs $130 to build using commercial off-the-shelf items. The use of two or three vacuum-insulated stainless-steel Thermos food jars containing heated water (for denaturation and annealing/extension steps) and a layer of oil on top of the water allow for significantly stabilized temperatures for PCR to take place. Using an Arduino-based microcontroller, we automate the “archaic” method of hand-transferring PCR tubes between water baths. Conclusions/Significance We demonstrate that this innovative unit can deliver high speed PCR (17 s per PCR cycle) with the potential to go beyond the 1,522 bp long amplicons tested in this study and can amplify from templates down to at least 20 copies per reaction. The unit also accepts regular PCR tubes and glass capillary tubes. The PCR efficiency of our thermal cycler is not different from other commercial thermal cyclers. When combined with a rapid nucleic acid detection approach

  16. Low cost carbon fiber technology development for carbon fiber composite applications.

    DOT National Transportation Integrated Search

    2012-04-01

    The objective of this project was to further develop low cost carbon fiber for a variety of potential applications. Manufacturing feasi-bility of low cost carbon fibers/composites has been demonstrated. A number of technologies that are currently usi...

  17. Low-Cost Charged-Coupled Device (CCD) Based Detectors for Shiga Toxins Activity Analysis.

    PubMed

    Rasooly, Reuven; Prickril, Ben; Bruck, Hugh A; Rasooly, Avraham

    2017-01-01

    To improve food safety there is a need to develop simple, low-cost sensitive devices for detection of food-borne pathogens and their toxins. We describe a simple, low-cost webcam-based detector which can be used for various optical detection modalities, including fluorescence, chemiluminescence, densitometry, and colorimetric assays. The portable battery-operated CCD-based detection system consists of four modules: (1) a webcam to measure and record light emission, (2) a sample plate to perform assays, (3) a light emitting diode (LED) for illumination, and (4) a portable computer to acquire and analyze images. To demonstrate the technology, we used a cell based assay for fluorescence detection of the activity of the food borne Shiga toxin type 2 (Stx2), differentiating between biologically active toxin and inactive toxin which is not a risk. The assay is based on Shiga toxin inhibition of cell protein synthesis measured through inhibition of the green fluorescent protein (GFP). In this assay, GFP emits light at 509 nm when excited with a blue LED equipped with a filter at 486 nm. The emitted light is then detected with a green filter at 535 nm. Toxin activity is measured through a reduction in the 509 nm emission. In this system the level of detection (LOD) for Stx2 was 0.1 pg/ml, similar to the LOD of commercial fluorometers. These results demonstrate the utility and potential of low cost detectors for toxin activity. This approach could be readily adapted to the detection of other food-borne toxins.

  18. Development of a low cost and low power consumption system for monitoring CO_{2} soil concentration in volcanic areas.

    NASA Astrophysics Data System (ADS)

    Awadallah Estévez, Shadia; Moure-García, David; Torres-González, Pedro; Acosta Sánchez, Leopoldo; Domínguez Cerdeña, Itahiza

    2017-04-01

    Volatiles dissolved in magma are released as gases when pressure or stress conditions change. H2O, CO2, SO2 and H2S are the most abundant gases involved in volcanic processes. Emission rates are related to changes in the volcanic activity. Therefore, in order to predict possible eruptive events, periodic measurements of CO2 concentrations from the soil should be carried out. In the last years, CO2 monitoring has been widespread for many reasons. A direct relationship between changes in volcanic activity and variations in concentration, diffuse flux and isotope ratios of this gas, have been observed prior to some eruptions or unrest processes. All these factors have pointed out the fact that CO2 emission data are crucial in volcanic monitoring programs. In addition, relevant instrumentation development has also taken place: improved accuracy, cost reduction and portability. Considering this, we propose a low cost and a low power consumption system for measuring CO2 concentration in the soil based on Arduino. Through a perforated pick-axe buried at a certain depth, gas samples are periodically taken with the aid of a piston. These samples are injected through a pneumatic circuit in the spectrometer, which measures the CO2 concentration. Simultaneously, the system records the following meteorological parameters: atmospheric pressure, precipitation, relative humidity and air and soil temperature. These parameters are used to correct their possible influence in the CO2 soil concentration. Data are locally stored (SD card) and transmitted via GPRS or WIFI to a data analysis center.

  19. Outsourcing Security Services for Low Performance Portable Devices

    NASA Astrophysics Data System (ADS)

    Szentgyörgyi, Attila; Korn, András

    The number of portable devices using wireless network technologies is on the rise. Some of these devices are incapable of, or at a disadvantage at using secure Internet services, because secure communication often requires comparatively high computing capacity. In this paper, we propose a solution which can be used to offer secure network services for low performance portable devices without severely degrading data transmission rates. We also show that using our approach these devices can utilize some secure network services which were so far unavailable to them due to a lack of software support. In order to back up our claims, we present performance measurement results obtained in a test network.

  20. Thermal infrared reference sources fabricated from low-cost components and materials

    NASA Astrophysics Data System (ADS)

    Hovland, Harald; Skauli, Torbjørn

    2018-04-01

    Mass markets, including mobile phones and automotive sensors, drive rapid developments of imaging technologies toward high performance, low cost sensors, even for the thermal infrared. Good infrared calibration blackbody sources have remained relatively costly, however. Here we demonstrate how to make low-cost reference sources, making quantitative infrared radiometry more accessible to a wider community. Our approach uses ordinary construction materials combined with low cost microcontrollers, digital temperature sensors and foil heater elements from massmarket 3D printers. Blackbodies are constructed from a foil heater of some chosen size and shape, attached to the back of a similarly shaped aluminum plate coated with commercial black paint, which normally exhibits high emissivity. The emissivity can be readily checked by using a thermal imager to view the reflection of a hot object. A digital temperature sensor is attached to the back of the plate. Thermal isolation of the backside minimizes temperature gradients through the plate, ensuring correct readings of the front temperature. The isolation also serves to minimize convection gradients and keeps power consumption low, which is useful for battery powered operation in the field. We demonstrate surface blackbodies (200x200 mm2) with surface homogeneities as low as 0.1°C at 100°C. Homogeneous heating and low thermal mass provides for fast settling time and setup/pack-down time. The approach is scalable to larger sizes by tiling, enabling portable and foldable square-meter-size or larger devices.

  1. Development and application of a low-cost, portable DOAS system for stratospheric composition monitoring over the Argentinean Patagonia and Antarctic stations.

    NASA Astrophysics Data System (ADS)

    Raponi, Marcelo; Jiménez, Rodrigo; Ristori, Pablo; Wolfram, Elian; Tocho, Jorge; Quel, Eduardo

    2010-05-01

    A significant fraction of the Argentinean population is seasonally exposed to elevated UV radiation, particularly during severe stratospheric ozone destruction episodes in Antarctica. In order to provide early alert, global monitoring and to improve our understanding of these phenomena, various Argentinean and international organizations maintain stratospheric composition remote sensing sites from the southern tip of Argentina (Patagonia) to Antarctica. The understating of the ozone destruction dynamics will be significantly improved if more sites were available. For instance, the Laser and Applications Research Center, CEILAP (CITEFA-CONICET, Argentina) carries out systematic measurements of stratospheric ozone and tropospheric water vapor profiles at Rio Gallego (51° 36' S, 69° 19' W, 15 m asl) by means of LIDAR systems. Besides the active systems, the site possesses different passive instruments (GUV-541, UV-B and UV-A radiometers, SAOZ spectrometer, CIMEL sunphotometer) all of them working in synergy. The goal of this work is to present the design and development of a new compact atmospheric remote sensing system, able to determine the vertical column concentration in column (VCD) of multiple trace gases. We have developed a low-cost, portable passive DOAS system, ERO-DOAS, wich circumvents the cost limitations associated with new fixed monitoring sites. It is composed of commercial spectrophotometer (HR4000, Ocean Optics), a 400-μm core, 6-m long optic fiber, and a home-made automatic external shutter. We have developed a LabVIEW® based software for spectrometer/shutter control and data acquisition, and a MATLAB® based software for spectral data reduction. In the work we highlight the main characteristics of the system's components and we describe the visual interface implemented to controls the operation of the whole system, and the calculation algorithms to process the measured zenithal spectra, postulating the strategies implemented to solve the

  2. Hot forming and quenching pilot process development for low cost and low environmental impact manufacturing.

    NASA Astrophysics Data System (ADS)

    Hall, Roger W.; Foster, Alistair; Herrmann Praturlon, Anja

    2017-09-01

    The Hot Forming and in-tool Quenching (HFQ®) process is a proven technique to enable complex shaped stampings to be manufactured from high strength aluminium. Its widespread uptake for high volume production will be maximised if it is able to wholly amortise the additional investment cost of this process compared to conventional deep drawing techniques. This paper discusses the use of three techniques to guide some of the development decisions taken during upscaling of the HFQ® process. Modelling of Process timing, Cost and Life-cycle impact were found to be effective tools to identify where development budget could be focused in order to be able to manufacture low cost panels of different sizes from many different alloys in a sustainable way. The results confirm that raw material cost, panel trimming, and artificial ageing were some of the highest contributing factors to final component cost. Additionally, heat treatment and lubricant removal stages played a significant role in the overall life-cycle assessment of the final products. These findings confirmed development priorities as novel furnace design, fast artificial ageing and low-cost alloy development.

  3. Air-Microfluidics: Creating Small, Low-cost, Portable Air Quality Sensors

    EPA Science Inventory

    Air-microfluidics shows great promise in dramatically reducing the size, cost, and power requirements of future air quality sensors without compromising their accuracy. Microfabrication provides a suite of relatively new tools for the development of micro electro mechanical syste...

  4. Low-Cost, Class D Testing of Spacecraft Photovoltaic Systems Can Reduce Risk

    NASA Technical Reports Server (NTRS)

    Forgione, Joshua B.; Kojima, Gilbert K.; Hanel, Robert; Mallinson, Mark

    2014-01-01

    The end-to-end verification of a spacecraft photovoltaic power generation system requires light! A lowcost, portable, and end-to-end photovoltaic-system test appropriate for NASA's new generation of Class D missions is presented. High risk, low-cost, and quick-turn satellites rarely have the resources to execute the traditional approaches from higher-class (A-C) missions. The Class D approach, as demonstrated on the Lunar Atmospheric and Dust Environment Explorer (LADEE), utilizes a portable, metalhalide, theatre lamp for an end-to-end photovoltaic system test. While not as precise and comprehensive as the traditional Large Area Pulsed Solar Simulator (LAPSS) test, the LADEE method leverages minimal resources into an ongoing assessment program that can be applied through numerous stages of the mission. The project takes a true Class D approach in assessing the technical value of a costly, highfidelity performance test versus a simpler approach with less programmatic risk. The resources required are a fraction of that for a LAPSS test, and is easy to repeat due to its portability. Further, the test equipment can be handed down to future projects without building an on-site facility. At the vanguard of Class D missions, the LADEE team frequently wrestled with and challenged the status quo. The philosophy of risk avoidance at all cost, typical to Class A-C missions, simply could not be executed. This innovative and simple testing solution is contextualized to NASA Class D programs and a specific risk encountered during development of the LADEE Electrical Power System (EPS). Selection of the appropriate lamp and safety concerns are discussed, with examples of test results. Combined with the vendor's panellevel data and periodic inspection, the method ensures system integrity from Integration and Test (I&T) through launch. Following launch, mission operations tools are utilized to assess system performance based on a scant amount of available data.

  5. A distributed network of low-cost continuous reading sensors to measure spatiotemporal variations of PM2.5 in Xi'an, China.

    PubMed

    Gao, Meiling; Cao, Junji; Seto, Edmund

    2015-04-01

    Fine particulate matter (PM2.5) is a growing public health concern especially in industrializing countries but existing monitoring networks are unable to properly characterize human exposures due to low resolution spatiotemporal data. Low-cost portable monitors can supplement existing networks in both developed and industrializing regions to increase density of sites and data. This study tests the performance of a low-cost sensor in high concentration urban environments. Seven Portable University of Washington Particle (PUWP) monitors were calibrated with optical and gravimetric PM2.5 reference monitors in Xi'an, China in December 2013. Pairwise correlations between the raw PUWP and the reference monitors were high (R(2) = 0.86-0.89). PUWP monitors were also simultaneously deployed at eight sites across Xi'an alongside gravimetric PM2.5 monitors (R(2) = 0.53). The PUWP monitors were able to identify the High-technology Zone site as a potential PM2.5 hotspot with sustained high concentrations compared to the city average throughout the day. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.

  6. Portable, lightweight, low power, ion chromatographic system with open tubular capillary columns.

    PubMed

    Kiplagat, Isaac K; Kubán, Petr; Pelcová, Pavlína; Kubán, Vlastimil

    2010-07-30

    Basic operation principles of a lightweight, low power, low cost, portable ion chromatograph utilizing open tubular ion chromatography in capillary columns coated with multi-layer polymeric stationary phases are demonstrated. A minimalistic configuration of a portable IC instrument was developed that does not require any chromatographic eluent delivery system, nor sample injection device as it uses gravity-based eluent flow and hydrodynamic sample injection adopted from capillary electrophoresis. As a detection device, an inexpensive commercially available capacitance sensor is used that has been shown to be a suitable substitute for contactless conductivity detection in capillary separation systems. The built-in temperature sensor allows for baseline drift correction typically encountered in conductivity/capacitance measurements without thermostating device. The whole instrument does not require any power supply for its operation, except the detection and data acquisition part that is provided by a USB port of a Netbook computer. It is extremely lightweight, its total weight including the Netbook computer is less than 2.5kg and it can be continuously operated for more than 8h. Several parameters of the instrument, such as detection cell design, eluent delivery systems and data treatment were optimized as well as the composition of eluent for non-suppressed ion chromatographic analysis of common inorganic cations (Na(+), NH(4)(+), K(+), Cs(+), Ca(2+), Mg(2+), transition metals). Low conductivity eluents based on weakly complexing organic acids such as tartaric, oxalic or pyridine-2,6-dicarboxylic acids were used with contactless capacitance detection for simultaneous separation of mono- and divalent cations. Separation of Na(+) and NH(4)(+) cations was optimized by addition of 18-crown-6 to the eluent. The best separation of 6 metal cations commonly present in various environmental samples was accomplished in less than 30min using a 1.75mM pyridine-2,6-dicarboxylic

  7. Low-cost and highly efficient DNA biosensor for heavy metal ion using specific DNAzyme-modified microplate and portable glucometer-based detection mode.

    PubMed

    Zhang, Jin; Tang, Ying; Teng, Liumei; Lu, Minghua; Tang, Dianping

    2015-06-15

    A simple and low-cost DNA sensing platform based on Pb(2+)-specific DNAzyme-modified microplate was successfully developed for highly sensitive monitoring of lead ion (Pb(2+), one kind of toxic heavy metal ion) in the environmental samples coupling with a portable personal glucometer (PGM)-based detection mode. The detection cell was first prepared simply by means of immobilizing the DNAzyme on the streptavidin-modified microplate. Gold nanoparticle labeled with single-stranded DNA and invertase (Enz-AuNP-DNA) was utilized as the signal-transduction tag to produce PGM substrate (glucose). Upon addition of lead ion into the microplate, the substrate strand of the immobilized DNAzyme was catalytically cleaved by target Pb(2+), and the newly generated single-strand DNA in the microplate could hybridize again with the single-stranded DNA on the Enz-AuNP-DNA. Accompanying with the Enz-AuNP-DNA, the carried invertase could convert sucrose into glucose. The as-produced glucose could be monitored by using a widely accessible PGM for in situ amplified digital readout. Based on Enz-AuNP-DNA amplification strategy, as low as 1.0 pM Pb(2+) could be detected under the optimal conditions. Moreover, the methodology also showed good reproducibility and high selectivity toward target Pb(2+) against other metal ions because of highly specific Pb(2+)-dependent DNAzyme, and was applicable for monitoring Pb(2+) in the naturally contaminated sewage and spiked drinking water samples. Copyright © 2015 Elsevier B.V. All rights reserved.

  8. Portable and cost-effective pixel super-resolution on-chip microscope for telemedicine applications.

    PubMed

    Bishara, Waheb; Sikora, Uzair; Mudanyali, Onur; Su, Ting-Wei; Yaglidere, Oguzhan; Luckhart, Shirley; Ozcan, Aydogan

    2011-01-01

    We report a field-portable lensless on-chip microscope with a lateral resolution of <1 μm and a large field-of-view of ~24 mm(2). This microscope is based on digital in-line holography and a pixel super-resolution algorithm to process multiple lensfree holograms and obtain a single high-resolution hologram. In its compact and cost-effective design, we utilize 23 light emitting diodes butt-coupled to 23 multi-mode optical fibers, and a simple optical filter, with no moving parts. Weighing only ~95 grams, we demonstrate the performance of this field-portable microscope by imaging various objects including human malaria parasites in thin blood smears.

  9. Design of low-cost general purpose microcontroller based neuromuscular stimulator.

    PubMed

    Koçer, S; Rahmi Canal, M; Güler, I

    2000-04-01

    In this study, a general purpose, low-cost, programmable, portable and high performance stimulator is designed and implemented. For this purpose, a microcontroller is used in the design of the stimulator. The duty cycle and amplitude of the designed system can be controlled using a keyboard. The performance test of the system has shown that the results are reliable. The overall system can be used as the neuromuscular stimulator under safe conditions.

  10. Portable Nanoparticle-Based Sensors for Food Safety Assessment

    PubMed Central

    Bülbül, Gonca; Hayat, Akhtar; Andreescu, Silvana

    2015-01-01

    The use of nanotechnology-derived products in the development of sensors and analytical measurement methodologies has increased significantly over the past decade. Nano-based sensing approaches include the use of nanoparticles (NPs) and nanostructures to enhance sensitivity and selectivity, design new detection schemes, improve sample preparation and increase portability. This review summarizes recent advancements in the design and development of NP-based sensors for assessing food safety. The most common types of NPs used to fabricate sensors for detection of food contaminants are discussed. Selected examples of NP-based detection schemes with colorimetric and electrochemical detection are provided with focus on sensors for the detection of chemical and biological contaminants including pesticides, heavy metals, bacterial pathogens and natural toxins. Current trends in the development of low-cost portable NP-based technology for rapid assessment of food safety as well as challenges for practical implementation and future research directions are discussed. PMID:26690169

  11. Portable Computer Technology (PCT) Research and Development Program Phase 2

    NASA Technical Reports Server (NTRS)

    Castillo, Michael; McGuire, Kenyon; Sorgi, Alan

    1995-01-01

    The subject of this project report, focused on: (1) Design and development of two Advanced Portable Workstation 2 (APW 2) units. These units incorporate advanced technology features such as a low power Pentium processor, a high resolution color display, National Television Standards Committee (NTSC) video handling capabilities, a Personal Computer Memory Card International Association (PCMCIA) interface, and Small Computer System Interface (SCSI) and ethernet interfaces. (2) Use these units to integrate and demonstrate advanced wireless network and portable video capabilities. (3) Qualification of the APW 2 systems for use in specific experiments aboard the Mir Space Station. A major objective of the PCT Phase 2 program was to help guide future choices in computing platforms and techniques for meeting National Aeronautics and Space Administration (NASA) mission objectives. The focus being on the development of optimal configurations of computing hardware, software applications, and network technologies for use on NASA missions.

  12. Design and development of a highly sensitive, field portable plasma source instrument for on-line liquid stream monitoring and real-time sample analysis

    NASA Astrophysics Data System (ADS)

    Duan, Yixiang; Su, Yongxuan; Jin, Zhe; Abeln, Stephen P.

    2000-03-01

    The development of a highly sensitive, field portable, low-powered instrument for on-site, real-time liquid waste stream monitoring is described in this article. A series of factors such as system sensitivity and portability, plasma source, sample introduction, desolvation system, power supply, and the instrument configuration, were carefully considered in the design of the portable instrument. A newly designed, miniature, modified microwave plasma source was selected as the emission source for spectroscopy measurement, and an integrated small spectrometer with a charge-coupled device detector was installed for signal processing and detection. An innovative beam collection system with optical fibers was designed and used for emission signal collection. Microwave plasma can be sustained with various gases at relatively low power, and it possesses high detection capabilities for both metal and nonmetal pollutants, making it desirable to use for on-site, real-time, liquid waste stream monitoring. An effective in situ sampling system was coupled with a high efficiency desolvation device for direct-sampling liquid samples into the plasma. A portable computer control system is used for data processing. The new, integrated instrument can be easily used for on-site, real-time monitoring in the field. The system possesses a series of advantages, including high sensitivity for metal and nonmetal elements; in situ sampling; compact structure; low cost; and ease of operation and handling. These advantages will significantly overcome the limitations of previous monitoring techniques and make great contributions to environmental restoration and monitoring.

  13. Moving toward rapid and low-cost point-of-care molecular diagnostics with a repurposed 3D printer and RPA.

    PubMed

    Chan, Kamfai; Wong, Pui-Yan; Parikh, Chaitanya; Wong, Season

    2018-03-15

    Traditionally, the majority of nucleic acid amplification-based molecular diagnostic tests are done in centralized settings. In recent years, point-of-care tests have been developed for use in low-resource settings away from central laboratories. While most experts agree that point-of-care molecular tests are greatly needed, their availability as cost-effective and easy-to-operate tests remains an unmet goal. In this article, we discuss our efforts to develop a recombinase polymerase amplification reaction-based test that will meet these criteria. First, we describe our efforts in repurposing a low-cost 3D printer as a platform that can carry out medium-throughput, rapid, and high-performing nucleic acid extraction. Next, we address how these purified templates can be rapidly amplified and analyzed using the 3D printer's heated bed or the deconstructed, low-cost thermal cycler we have developed. In both approaches, real-time isothermal amplification and detection of template DNA or RNA can be accomplished using a low-cost portable detector or smartphone camera. Last, we demonstrate the capability of our technologies using foodborne pathogens and the Zika virus. Our low-cost approach does not employ complicated and high-cost components, making it suitable for resource-limited settings. When integrated and commercialized, it will offer simple sample-to-answer molecular diagnostics. Copyright © 2018 Elsevier Inc. All rights reserved.

  14. A Compact and Low Cost Electronic Nose for Aroma Detection

    PubMed Central

    Macías, Miguel Macías; Agudo, J. Enrique; Manso, Antonio García; Orellana, Carlos Javier García; Velasco, Horacio Manuel González; Caballero, Ramón Gallardo

    2013-01-01

    This article explains the development of a prototype of a portable and a very low-cost electronic nose based on an mbed microcontroller. Mbeds are a series of ARM microcontroller development boards designed for fast, flexible and rapid prototyping. The electronic nose is comprised of an mbed, an LCD display, two small pumps, two electro-valves and a sensor chamber with four TGS Figaro gas sensors. The performance of the electronic nose has been tested by measuring the ethanol content of wine synthetic matrices and special attention has been paid to the reproducibility and repeatability of the measurements taken on different days. Results show that the electronic nose with a neural network classifier is able to discriminate wine samples with 10, 12 and 14% V/V alcohol content with a classification error of less than 1%. PMID:23698265

  15. Towards low cost photoacoustic Microscopy system for evaluation of skin health

    NASA Astrophysics Data System (ADS)

    Hariri, Ali; Fatima, Afreen; Mohammadian, Nafiseh; Bely, Nicholas; Nasiriavanaki, Mohammadreza

    2016-09-01

    Photoacoustic imaging (PAI) involves both optical and ultrasound imaging, owing to this combination the system is capable of generating high resolution images with good penetration depth. With the growing applications of PAI in neurology, vascular biology, dermatology, ophthalmology, tissue engineering, angiogenesis etc., there is a need to make the system more compact, cheap and effective. Therefore we designed an economical and compact version of PAI systems by replacing expensive and sophisticated lasers with a robust pulsed laser diode of 905 nm wavelength. In this study, we determine the feasibility of the Photoacoustic imaging with a very low excitation energy of 0.1uJ in Photoacoustic microscopy. We developed a low cost portable Photoacoustic Imaging including microscopy (both reflection) Phantom study was performed in this configuration and also ex-vivo image was obtained from mouse skin.

  16. A Rapid and Low-Cost PCR Thermal Cycler for Infectious Disease Diagnostics

    PubMed Central

    Chan, Kamfai; Wong, Pui-Yan; Yu, Peter; Hardick, Justin; Wong, Kah-Yat; Wilson, Scott A.; Wu, Tiffany; Hui, Zoe; Gaydos, Charlotte; Wong, Season S.

    2016-01-01

    The ability to make rapid diagnosis of infectious diseases broadly available in a portable, low-cost format would mark a great step forward in global health. Many molecular diagnostic assays are developed based on using thermal cyclers to carry out polymerase chain reaction (PCR) and reverse-transcription PCR for DNA and RNA amplification and detection, respectively. Unfortunately, most commercial thermal cyclers are expensive and need continuous electrical power supply, so they are not suitable for uses in low-resource settings. We have previously reported a low-cost and simple approach to amplify DNA using vacuum insulated stainless steel thermoses food cans, which we have named it thermos thermal cycler or TTC. Here, we describe the use of an improved set up to enable the detection of viral RNA targets by reverse-transcription PCR (RT-PCR), thus expanding the TTC’s ability to identify highly infectious, RNA virus-based diseases in low resource settings. The TTC was successful in demonstrating high-speed and sensitive detection of DNA or RNA targets of sexually transmitted diseases, HIV/AIDS, Ebola hemorrhagic fever, and dengue fever. Our innovative TTC costs less than $200 to build and has a capacity of at least eight tubes. In terms of speed, the TTC’s performance exceeded that of commercial thermal cyclers tested. When coupled with low-cost endpoint detection technologies such as nucleic acid lateral-flow assay or a cell-phone-based fluorescence detector, the TTC will increase the availability of on-site molecular diagnostics in low-resource settings. PMID:26872358

  17. Portable device for the detection of colorimetric assays

    PubMed Central

    Nowak, E.; Kawchuk, J.; Hoorfar, M.; Najjaran, H.

    2017-01-01

    In this work, a low-cost, portable device is developed to detect colorimetric assays for in-field and point-of-care (POC) analysis. The device can rapidly detect both pH values and nitrite concentrations of five different samples, simultaneously. After mixing samples with specific reagents, a high-resolution digital camera collects a picture of the sample, and a single-board computer processes the image in real time to identify the hue–saturation–value coordinates of the image. An internal light source reduces the effect of any ambient light so the device can accurately determine the corresponding pH values or nitrite concentrations. The device was purposefully designed to be low-cost, yet versatile, and the accuracy of the results have been compared to those from a conventional method. The results obtained for pH values have a mean standard deviation of 0.03 and a correlation coefficient R2 of 0.998. The detection of nitrites is between concentrations of 0.4–1.6 mg l−1, with a low detection limit of 0.2 mg l−1, and has a mean standard deviation of 0.073 and an R2 value of 0.999. The results represent great potential of the proposed portable device as an excellent analytical tool for POC colorimetric analysis and offer broad accessibility in resource-limited settings. PMID:29291093

  18. Development and flight test of a helicopter compact, portable, precision landing system concept

    NASA Technical Reports Server (NTRS)

    Clary, G. R.; Bull, J. S.; Davis, T. J.; Chisholm, J. P.

    1984-01-01

    An airborne, radar-based, precision approach concept is being developed and flight tested as a part of NASA's Rotorcraft All-Weather Operations Research Program. A transponder-based beacon landing system (BLS) applying state-of-the-art X-band radar technology and digital processing techniques, was built and is being flight tested to demonstrate the concept feasibility. The BLS airborne hardware consists of an add-on microprocessor, installed in conjunction with the aircraft weather/mapping radar, which analyzes the radar beacon receiver returns and determines range, localizer deviation, and glide-slope deviation. The ground station is an inexpensive, portable unit which can be quickly deployed at a landing site. Results from the flight test program show that the BLS concept has a significant potential for providing rotorcraft with low-cost, precision instrument approach capability in remote areas.

  19. A microcontroller-based portable electrocardiograph recorder.

    PubMed

    Segura-Juárez, José J; Cuesta-Frau, David; Samblas-Pena, Luis; Aboy, Mateo

    2004-09-01

    We describe a low cost portable Holter design that can be implemented with off-the-shelf components. The recorder is battery powered and includes a graphical display and keyboard. The recorder is capable of acquiring up to 48 hours of continuous electrocardiogram data at a sample rate of up to 250 Hz.

  20. Technology assessment of portable energy RDT and P, phase 1

    NASA Technical Reports Server (NTRS)

    Spraul, J. R. (Compiler)

    1975-01-01

    A technological assessment of portable energy research, development, technology, and production was undertaken to assess the technical, economic, environmental, and sociopolitical issues associated with portable energy options. Those courses of action are discussed which would impact aviation and air transportation research and technology. Technology assessment workshops were held to develop problem statements. The eighteen portable energy problem statements are discussed in detail along with each program's objective, approach, task description, and estimates of time and costs.

  1. An Instantaneous Low-Cost Point-of-Care Anemia Detection Device

    PubMed Central

    Punter-Villagrasa, Jaime; Cid, Joan; Páez-Avilés, Cristina; Rodríguez-Villarreal, Ivón; Juanola-Feliu, Esteve; Colomer-Farrarons, Jordi; Miribel-Català, Pere Ll.

    2015-01-01

    We present a small, compact and portable device for point-of-care instantaneous early detection of anemia. The method used is based on direct hematocrit measurement from whole blood samples by means of impedance analysis. This device consists of a custom electronic instrumentation and a plug-and-play disposable sensor. The designed electronics rely on straightforward standards for low power consumption, resulting in a robust and low consumption device making it completely mobile with a long battery life. Another approach could be powering the system based on other solutions like indoor solar cells, or applying energy-harvesting solutions in order to remove the batteries. The sensing system is based on a disposable low-cost label-free three gold electrode commercial sensor for 50 μL blood samples. The device capability for anemia detection has been validated through 24 blood samples, obtained from four hospitalized patients at Hospital Clínic. As a result, the response, effectiveness and robustness of the portable point-of-care device to detect anemia has been proved with an accuracy error of 2.83% and a mean coefficient of variation of 2.57% without any particular case above 5%. PMID:25690552

  2. Validation of a low-cost EEG device for mood induction studies.

    PubMed

    Rodríguez, Alejandro; Rey, Beatriz; Alcañiz, Mariano

    2013-01-01

    New electroencephalography (EEG) devices, more portable and cheaper, are appearing on the market. Studying the reliability of these EEG devices for emotional studies would be interesting, as these devices could be more economical and compatible with Virtual Reality (VR) settings. Therefore, the aim in this work was to validate a low-cost EEG device (Emotiv Epoc) to monitor brain activity during a positive emotional induction procedure. Emotional pictures (IAPS) were used to induce a positive mood in sixteen participants. Changes in the brain activity of subjects were compared between positive induction and neutral conditions. Obtained results were in accordance with previous scientific literature regarding frontal EEG asymmetry, which supports the possibility of using this low-cost EEG device in future mood induction studies combined with VR.

  3. Spatial and Temporal Trends of Air Pollutants in the South Coast Basin Using Low Cost Sensors

    EPA Science Inventory

    The emergence of small, portable, low-cost air sensors has encouraged a shift from traditional monitoring approaches for air quality. The U.S. Environmental Protection Agency (U.S. EPA), in collaboration with the South Coast Air Quality Management District’s (SCAQMD) Air Quality ...

  4. The Evaluation of a Low-Cost Colorimeter for Glucose Detection in Salivary Samples.

    PubMed

    Dominguez, Rocio B; Orozco, Miguel A; Chávez, Giovanny; Márquez-Lucero, Alfredo

    2017-11-01

    Given the limited access to healthcare resources, low-income settings require the development of affordable technology. Here we present the design and evaluation of a low-cost colorimeter applied to the non-invasive monitoring of Diabetes Mellitus through the detection of glucose in salival fluid. Samples were processed by the glucose oxidase-peroxidase enzymatic system and analyzed with the development equipment. A light emission diode of 532.5 nm was used as an excitation source and a RGB module was used as a receptor. A calibration curve to quantify the concentration of salivary glucose (0 to 18 mg/dL) was carried out by relating the RGB components registered with glucose concentrations, achieving a limit of detection of 0.17 mg/dL with a CV of 5% (n = 3). Salivary samples of diabetic and healthy volunteers were processed with the equipment showing an average concentration of 1.5519 ± 0.4511 mg/dL for the first and 4.0479 ± 1.6103 mg/dL for the last, allowing a discrimination between both groups. Results were validated against a UV-Vis-NIR spectrophotometer with a correspondence of R² of 0.98194 between both instruments. Results suggest the potential application of the developed device to the sensitive detection of relevant analytes with a low-cost, user-friendly, low-power and portable instrumentation.

  5. The Evaluation of a Low-Cost Colorimeter for Glucose Detection in Salivary Samples

    PubMed Central

    Dominguez, Rocio B.; Orozco, Miguel A.; Chávez, Giovanny; Márquez-Lucero, Alfredo

    2017-01-01

    Given the limited access to healthcare resources, low-income settings require the development of affordable technology. Here we present the design and evaluation of a low-cost colorimeter applied to the non-invasive monitoring of Diabetes Mellitus through the detection of glucose in salival fluid. Samples were processed by the glucose oxidase-peroxidase enzymatic system and analyzed with the development equipment. A light emission diode of 532.5 nm was used as an excitation source and a RGB module was used as a receptor. A calibration curve to quantify the concentration of salivary glucose (0 to 18 mg/dL) was carried out by relating the RGB components registered with glucose concentrations, achieving a limit of detection of 0.17 mg/dL with a CV of 5% (n = 3). Salivary samples of diabetic and healthy volunteers were processed with the equipment showing an average concentration of 1.5519 ± 0.4511 mg/dL for the first and 4.0479 ± 1.6103 mg/dL for the last, allowing a discrimination between both groups. Results were validated against a UV-Vis-NIR spectrophotometer with a correspondence of R2 of 0.98194 between both instruments. Results suggest the potential application of the developed device to the sensitive detection of relevant analytes with a low-cost, user-friendly, low-power and portable instrumentation. PMID:29104212

  6. Development of a portable analyzer with polymer lab-on-a-chip (LOC) for continuous sampling and monitoring of Pb(II).

    PubMed

    Jang, A; Zou, Z; MacKnight, E; Wu, P M; Kim, I S; Ahn, C H; Bishop, P L

    2009-01-01

    A new portable analyzer with polymer lab-on-a-chip (LOC) has been designed, fabricated and fully characterized for continuous sampling and monitoring of lead (Pb(II)) in this work. As the working electrodes of the sensor, bismuth (Bi (III)) which allowed the advantage of being more environmentally friendly than traditional mercury drop electrodes was used, while maintaining similar sensitivity and other desirable characteristics. The size of a portable analyzer was 30 cmx23 cmx7 cm, and the weight was around 3 kg. The small size gives the advantage of being portable for field use while not sacrificing portability for accuracy of measurement. Furthermore, the autonomous system developed in coordination with the development of new polymer LOC integrated with electrochemical sensors can provide an innovative way to monitor surface waters in an efficient, cost-effective and sustainable manner.

  7. 47 CFR 52.32 - Allocation of the shared costs of long-term number portability.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ....21(h), of each regional database, as defined in § 52.21(1), shall recover the shared costs of long-term number portability attributable to that regional database from all telecommunications carriers providing telecommunications service in areas that regional database serves. Pursuant to its duties under...

  8. 47 CFR 52.32 - Allocation of the shared costs of long-term number portability.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ....21(h), of each regional database, as defined in § 52.21(1), shall recover the shared costs of long-term number portability attributable to that regional database from all telecommunications carriers providing telecommunications service in areas that regional database serves. Pursuant to its duties under...

  9. 47 CFR 52.32 - Allocation of the shared costs of long-term number portability.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ....21(h), of each regional database, as defined in § 52.21(1), shall recover the shared costs of long-term number portability attributable to that regional database from all telecommunications carriers providing telecommunications service in areas that regional database serves. Pursuant to its duties under...

  10. 47 CFR 52.32 - Allocation of the shared costs of long-term number portability.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ....21(h), of each regional database, as defined in § 52.21(1), shall recover the shared costs of long-term number portability attributable to that regional database from all telecommunications carriers providing telecommunications service in areas that regional database serves. Pursuant to its duties under...

  11. 47 CFR 52.32 - Allocation of the shared costs of long-term number portability.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ....21(h), of each regional database, as defined in § 52.21(1), shall recover the shared costs of long-term number portability attributable to that regional database from all telecommunications carriers providing telecommunications service in areas that regional database serves. Pursuant to its duties under...

  12. Development of a Low-Cost Attitude Sensor for Agricultural Vehicles

    USDA-ARS?s Scientific Manuscript database

    The objective of this research was to develop a low-cost attitude sensor for agricultural vehicles. The attitude sensor was composed of three vibratory gyroscopes and two inclinometers. A sensor fusion algorithm was developed to estimate tilt angles (roll and pitch) by least-squares method. In the a...

  13. Low-cost near-infrared measurement of subcutaneous fat for newborn malnutrition

    NASA Astrophysics Data System (ADS)

    McEwan, A. L.; Bian, S.; Gargiulo, G. D.; Morhard, R.; Jones, P.; Mustafa, F. H.; Bek, B. Emily; Jeffery, H. E.

    2014-04-01

    Low fat composition in newborns exposes them to an immediate risk of increased mortality and morbidity, inhibited physical and cognitive development and to diabetes and obesity diseases in later life. Information about nutritional and dietary status of newborns can be accessed by measuring the amount of fat composition in the body. The functions of subcutaneous fat involve energy storage, thermo-insulation and a physical buffer. Current technologies for newborn body fat monitoring are: a device based on air displacement plethesmography (PeaPod), dual-energy Xray, and underwater weighting. However they are bulky, expensive, immobile, and require technical expertise. We propose an alternative portable measurement system of in-vitro for subcutaneous fat that uses diffuse near-infrared light reflectance measurement system. We also introduce an in-vitro three-layered tissue model mimicking the subcutaneous fat layer in newborns together with a preliminary study to measure fat using dual-wavelength nearinfrared light. Based on the output data from these measurements, we have proposed a suitable transmission and scattering model. This model estimated the amount of reflected light collected by a photodetector after incident light is scattered in several fat layers. Our portable sensor is low cost and does not require training hence it is suitable for mass use in the developing world. It consists of a single LED and two photodetectors (900 nm and 1000 nm). The photodetectors wavelengths were chosen to be sensitive to fat as it exhibits a peak in the wavelength at 930 nm and to water at which exhibits a peak at 980 nm; the latter is used, to remove hydration bias. Results on a porcine tissue model demonstrate differentiation as low as 2 mm fat which is a relevant screening thickness to indicate low percentage body fat.

  14. Development of low-cost high-performance multispectral camera system at Banpil

    NASA Astrophysics Data System (ADS)

    Oduor, Patrick; Mizuno, Genki; Olah, Robert; Dutta, Achyut K.

    2014-05-01

    Banpil Photonics (Banpil) has developed a low-cost high-performance multispectral camera system for Visible to Short- Wave Infrared (VIS-SWIR) imaging for the most demanding high-sensitivity and high-speed military, commercial and industrial applications. The 640x512 pixel InGaAs uncooled camera system is designed to provide a compact, smallform factor to within a cubic inch, high sensitivity needing less than 100 electrons, high dynamic range exceeding 190 dB, high-frame rates greater than 1000 frames per second (FPS) at full resolution, and low power consumption below 1W. This is practically all the feature benefits highly desirable in military imaging applications to expand deployment to every warfighter, while also maintaining a low-cost structure demanded for scaling into commercial markets. This paper describes Banpil's development of the camera system including the features of the image sensor with an innovation integrating advanced digital electronics functionality, which has made the confluence of high-performance capabilities on the same imaging platform practical at low cost. It discusses the strategies employed including innovations of the key components (e.g. focal plane array (FPA) and Read-Out Integrated Circuitry (ROIC)) within our control while maintaining a fabless model, and strategic collaboration with partners to attain additional cost reductions on optics, electronics, and packaging. We highlight the challenges and potential opportunities for further cost reductions to achieve a goal of a sub-$1000 uncooled high-performance camera system. Finally, a brief overview of emerging military, commercial and industrial applications that will benefit from this high performance imaging system and their forecast cost structure is presented.

  15. A portable low-cost 3D point cloud acquiring method based on structure light

    NASA Astrophysics Data System (ADS)

    Gui, Li; Zheng, Shunyi; Huang, Xia; Zhao, Like; Ma, Hao; Ge, Chao; Tang, Qiuxia

    2018-03-01

    A fast and low-cost method of acquiring 3D point cloud data is proposed in this paper, which can solve the problems of lack of texture information and low efficiency of acquiring point cloud data with only one pair of cheap cameras and projector. Firstly, we put forward a scene adaptive design method of random encoding pattern, that is, a coding pattern is projected onto the target surface in order to form texture information, which is favorable for image matching. Subsequently, we design an efficient dense matching algorithm that fits the projected texture. After the optimization of global algorithm and multi-kernel parallel development with the fusion of hardware and software, a fast acquisition system of point-cloud data is accomplished. Through the evaluation of point cloud accuracy, the results show that point cloud acquired by the method proposed in this paper has higher precision. What`s more, the scanning speed meets the demand of dynamic occasion and has better practical application value.

  16. A low-cost, portable, micro-controlled device for multi-channel LED visual stimulation.

    PubMed

    Pinto, Marcos Antonio da Silva; de Souza, John Kennedy Schettino; Baron, Jerome; Tierra-Criollo, Carlos Julio

    2011-04-15

    Light emitting diodes (LEDs) are extensively used as light sources to investigate visual and visually related function and dysfunction. Here, we describe the design of a compact, low-cost, stand-alone LED-based system that enables the configuration, storage and presentation of elaborate visual stimulation paradigms. The core functionality of this system is provided by a microcontroller whose ultra-low power consumption makes it well suited for long lasting battery applications. The effective use of hardware resources is managed by multi-layered architecture software that provides an intuitive and user-friendly interface. In the configuration mode, different stimulation sequences can be created and memorized for ten channels, independently. LED-driving current output can be set either as continuous or pulse modulated, up to 500 Hz, by duty cycle adjustments. In run mode, multiple-channel stimulus sequences are automatically applied according to the pre-programmed protocol. Steady state visual evoked potentials were successfully recorded in five subjects with no visible electromagnetic interferences from the stimulator, demonstrating the efficacy of combining our prototyped equipment with electrophysiological techniques. Finally, we discuss a number of possible improvements for future development of our project. Copyright © 2011 Elsevier B.V. All rights reserved.

  17. Portable smartphone based quantitative phase microscope

    NASA Astrophysics Data System (ADS)

    Meng, Xin; Tian, Xiaolin; Yu, Wei; Kong, Yan; Jiang, Zhilong; Liu, Fei; Xue, Liang; Liu, Cheng; Wang, Shouyu

    2018-01-01

    To realize portable device with high contrast imaging capability, we designed a quantitative phase microscope using transport of intensity equation method based on a smartphone. The whole system employs an objective and an eyepiece as imaging system and a cost-effective LED as illumination source. A 3-D printed cradle is used to align these components. Images of different focal planes are captured by manual focusing, followed by calculation of sample phase via a self-developed Android application. To validate its accuracy, we first tested the device by measuring a random phase plate with known phases, and then red blood cell smear, Pap smear, broad bean epidermis sections and monocot root were also measured to show its performance. Owing to its advantages as accuracy, high-contrast, cost-effective and portability, the portable smartphone based quantitative phase microscope is a promising tool which can be future adopted in remote healthcare and medical diagnosis.

  18. Lunar Prospector: developing a very low cost planetary mission.

    NASA Astrophysics Data System (ADS)

    Hubbard, G. S.

    Lunar Prospector, the first competitively selected planetary mission in NASA's Discovery Program, is described with emphasis on the lessons learned from managing a very low cost project. Insights into government-industry teaming, project management, contractual arrangements, schedule and budget reserve approach are discussed. The mission is conducting an orbital survey of the Moon's composition and structure. A mission overview and scientific data return is briefly described in the context of low cost mission development. The suite of five instruments is outlined: neutron spectrometer (NS), alpha particle spectrometer (APS), gamma ray spectrometer (GRS), magnetometer (MAG) and an electron reflectometer (ER). Scientific requirements and measurement approaches to detect water ice to a sensitivity of 50 ppm (hydrogen), measure key elemental constituents, detect gas release events and accurately map the Moon's gravitational and magnetic fields are described.

  19. Development of a portable photosynthesis rate measurement device

    NASA Astrophysics Data System (ADS)

    Wang, Junsheng; Xing, Da; Xu, Wenhai

    2006-09-01

    Photosynthesis is a very important chemical reaction in the plant, and its measurement plays critical role in the agriculture production and science research of plant. Delayed fluorescence (DF) in plants is an intrinsic label of efficiency of charge separation at P680 in photosystem II (PS II). In this paper, a portable photosynthesis rate measurement device by means of DF is proposed. It can achieve DF of plant with high sensitivity and signal-to-noise ratio basing on ultra-weak luminescence detection technique, and get photosynthesis rate by the corresponding relation between DF and photosynthesis rate. The device has its illumination power and can obtain all-weather measurement with less interference of the environment. Locale live survey can be realized by hermetic darkroom design and battery power supply. The system carries out data acquisition and processing by single-chip microcomputer control. The results show that this instrument has a lot of values such as low cost, high accuracy and good reliability and convenience.

  20. [Study cost/effectiveness of portable fridges in the mobile unit of emergencies of Alcañiz (Teruel)].

    PubMed

    Mir Ramos, Eduardo; Martínez Tofé, Jesús; Castro Salanova, Rafael; Azón López, Esther; Corcuera Cantabrana, Ana; Sancho Pellicer, Antonio

    2012-09-01

    The maintenance of cold chain can result difficult in Emergency Mobil Units that's why the aim of this study is to value the effectiveness of portable fridges with/without compressor and its cost-effectiveness by a computer simulation. This descriptive, transversal and cost effectiveness analysis was developed in two Emergency Mobil Units of 061 Aragón of Alcañiz (Teruel) along a year. The results showed that in the fridge with compressor, the 93'8% of the temperatures was between 2 and 8 degrees C, where as in the fridge without compressor was of the 35,7%.The global and specific cost effectiveness ratio of the fridge with and without compressor were of 0,063 and 7,411 and of 0,080 and 147,55 respectively. Fridge with compressor was more cost-effective, amortizing quickly its initial cost. This fridge had a better and more efficient thermoregulation what supposed a better conservation of drugs and lower costs, according to the model of simulation.

  1. Development of a Low cost Ultra tiny Line Laser Range Sensor

    DTIC Science & Technology

    2016-12-01

    Development of a Low-cost Ultra-tiny Line Laser Range Sensor Xiangyu Chen∗, Moju Zhao∗, Lingzhu Xiang†, Fumihito Sugai∗, Hiroaki Yaguchi∗, Kei Okada...and Masayuki Inaba∗ Abstract— To enable robotic sensing for tasks with require- ments on weight, size, and cost, we develop an ultra-tiny line laser ...view customizable using different laser lenses. The optimal measurement range of the sensor is 0.05[m] ∼ 2[m]. Higher sampling rates can be achieved

  2. Silicon web process development. [for low cost solar cells

    NASA Technical Reports Server (NTRS)

    Duncan, C. S.; Hopkins, R. H.; Seidensticker, R. G.; Mchugh, J. P.; Hill, F. E.; Heimlich, M. E.; Driggers, J. M.

    1979-01-01

    Silicon dendritic web, a single crystal ribbon shaped during growth by crystallographic forces and surface tension (rather than dies), is a highly promising base material for efficient low cost solar cells. The form of the product smooth, flexible strips 100 to 200 microns thick, conserves expensive silicon and facilitates automation of crystal growth and the subsequent manufacturing of solar cells. These characteristics, coupled with the highest demonstrated ribbon solar cell efficiency-15.5%-make silicon web a leading candidate to achieve, or better, the 1986 Low Cost Solar Array (LSA) Project cost objective of 50 cents per peak watt of photovoltaic output power. The main objective of the Web Program, technology development to significantly increase web output rate, and to show the feasibility for simultaneous melt replenishment and growth, have largely been accomplished. Recently, web output rates of 23.6 sq cm/min, nearly three times the 8 sq cm/min maximum rate of a year ago, were achieved. Webs 4 cm wide or greater were grown on a number of occassions.

  3. A compact, portable and low cost generic interrogation strain sensor system using an embedded VCSEL, detector and fibre Bragg grating

    NASA Astrophysics Data System (ADS)

    Lee, Graham C. B.; Van Hoe, Bram; Yan, Zhijun; Maskery, Oliver; Sugden, Kate; Webb, David; Van Steenberge, Geert

    2012-03-01

    We present a compact, portable and low cost generic interrogation strain sensor system using a fibre Bragg grating configured in transmission mode with a vertical-cavity surface-emitting laser (VCSEL) light source and a GaAs photodetector embedded in a polymer skin. The photocurrent value is read and stored by a microcontroller. In addition, the photocurrent data is sent via Bluetooth to a computer or tablet device that can present the live data in a real time graph. With a matched grating and VCSEL, the system is able to automatically scan and lock the VCSEL to the most sensitive edge of the grating. Commercially available VCSEL and photodetector chips are thinned down to 20 μm and integrated in an ultra-thin flexible optical foil using several thin film deposition steps. A dedicated micro mirror plug is fabricated to couple the driving optoelectronics to the fibre sensors. The resulting optoelectronic package can be embedded in a thin, planar sensing sheet and the host material for this sheet is a flexible and stretchable polymer. The result is a fully embedded fibre sensing system - a photonic skin. Further investigations are currently being carried out to determine the stability and robustness of the embedded optoelectronic components.

  4. A strategy for low cost development of incremental oil in legacy reservoirs

    USGS Publications Warehouse

    Attanasi, E.D.

    2016-01-01

    The precipitous decline in oil prices during 2015 has forced operators to search for ways to develop low-cost and low-risk oil reserves. This study examines strategies to low cost development of legacy reservoirs, particularly those which have already implemented a carbon dioxide enhanced oil recovery (CO2 EOR) program. Initially the study examines the occurrence and nature of the distribution of the oil resources that are targets for miscible and near-miscible CO2 EOR programs. The analysis then examines determinants of technical recovery through the analysis of representative clastic and carbonate reservoirs. The economic analysis focusses on delineating the dominant components of investment and operational costs. The concluding sections describe options to maximize the value of assets that the operator of such a legacy reservoir may have that include incremental expansion within the same producing zone and to producing zones that are laterally or stratigraphically near main producing zones. The analysis identified the CO2 recycle plant as the dominant investment cost item and purchased CO2 and liquids management as a dominant operational cost items. Strategies to utilize recycle plants for processing CO2 from multiple producing zones and multiple reservoir units can significantly reduce costs. Industrial sources for CO2 should be investigated as a possibly less costly way of meeting EOR requirements. Implementation of tapered water alternating gas injection schemes can partially mitigate increases in fluid lifting costs.

  5. Portable Bladder Ultrasound

    PubMed Central

    2006-01-01

    ranged from 38% to 72%. In sum, all but one study advocated the use of portable bladder ultrasound as an alternative to catheterization. Economic Analysis An economic analysis estimating the budget-impact of BladderScan in complex continuing care facilities was completed. The analysis results indicated a $192,499 (Cdn) cost-savings per year per facility and a cost-savings of $2,887,485 (Cdn) for all 15 CCC facilities. No economic analysis was completed for long-term care and acute care facilities due to lack of data. Considerations for Policy Development Rapid diffusion of portable bladder ultrasound technology is expected. Recently, the IC5 project on improving continence care in Ontario’s complex continuing care centres piloted portable bladder ultrasound at 12 sites. Preliminary results were promising. Many physicians and health care facilities already have portable bladder ultrasound devices. However, portable bladder ultrasound devices for PVR measurement are not in use at most health care facilities in Ontario and Canada. The Verathon Corporation (Bothell, Wisconsin, United States), which patents BladderScan, is the sole licensed manufacturer of the portable bladder ultrasound in Canada. Field monopoly may influence the rising costs of portable bladder ultrasound, particularly when faced with rapid expansion of the technology. Several thousand residents of Ontario would benefit from portable bladder ultrasound. The number of residents of Ontario that would benefit from the technology is difficult to quantify, because the incidence and prevalence of incontinence are grossly under-reported. However, long-term care and complex continuing care institutions would benefit greatly from portable bladder ultrasound, as would numerous rehabilitation units, postsurgical care units, and urology clinics. The cost of the portable bladder ultrasound devices ranges from $17,698.90 to $19,565.95 (Cdn) (total purchase price per unit as quoted by the manufacturer). Additional

  6. Low-cost solar array structure development

    NASA Astrophysics Data System (ADS)

    Wilson, A. H.

    1981-06-01

    Early studies of flat-plate arrays have projected costs on the order of $50/square meter for installed array support structures. This report describes an optimized low-cost frame-truss structure that is estimated to cost below $25/square meter, including all markups, shipping an installation. The structure utilizes a planar frame made of members formed from light-gauge galvanized steel sheet and is supposed in the field by treated-wood trusses that are partially buried in trenches. The buried trusses use the overburden soil to carry uplift wind loads and thus to obviate reinforced-concrete foundations. Details of the concept, including design rationale, fabrication and assembly experience, structural testing and fabrication drawings are included.

  7. Low-cost solar array structure development

    NASA Technical Reports Server (NTRS)

    Wilson, A. H.

    1981-01-01

    Early studies of flat-plate arrays have projected costs on the order of $50/square meter for installed array support structures. This report describes an optimized low-cost frame-truss structure that is estimated to cost below $25/square meter, including all markups, shipping an installation. The structure utilizes a planar frame made of members formed from light-gauge galvanized steel sheet and is supposed in the field by treated-wood trusses that are partially buried in trenches. The buried trusses use the overburden soil to carry uplift wind loads and thus to obviate reinforced-concrete foundations. Details of the concept, including design rationale, fabrication and assembly experience, structural testing and fabrication drawings are included.

  8. Development of a portable frequency-domain angle-resolved low coherence interferometry system

    NASA Astrophysics Data System (ADS)

    Pyhtila, John W.; Wax, Adam

    2007-02-01

    Improved methods for detecting dysplasia, or pre-cancerous growth, are a current clinical need. Random biopsy and subsequent diagnosis through histological analysis is the current gold standard in endoscopic surveillance for dysplasia. However, this approach only allows limited examination of the at-risk tissue and has the drawback of a long delay in time-to-diagnosis. In contrast, optical scattering spectroscopy methods offer the potential to assess cellular structure and organization in vivo, thus allowing for instantaneous diagnosis and increased coverage of the at-risk tissue. Angle-resolved low coherence interferometry (a/LCI), a novel scattering spectroscopy technique, combines the ability of low-coherence interferometry to isolate scattered light from sub-surface tissue layers with the ability of light scattering spectroscopy to obtain structural information on sub-wavelength scales, specifically by analyzing the angular distribution of the backscattered light. In application to examining tissue, a/LCI enables depthresolved quantitative measurements of changes in the size and texture of cell nuclei, which are characteristic biomarkers of dysplasia. The capabilities of a/LCI were demonstrated initially by detecting pre-cancerous changes in epithelial cells within intact, unprocessed, animal tissues. Recently, we have developed a new frequency-domain a/LCI system, with sub-second acquisition time and a novel fiber optic probe. Preliminary results using the fa/LCI system to examine human esophageal tissue in Barrett's esophagus patients demonstrate the clinical viability of the approach. In this paper, we present a new portable system which improves upon the design of the fa/LCI system to allow for higher quality data to be collected in the clinic. Accurate sizing of polystyrene microspheres and cell nuclei from ex vivo human esophageal tissue is presented. These results demonstrate the promise of a/LCI as a clinically viable diagnostic tool.

  9. Investigating Low-Cost Optical Spectroscopy for Sensing Pressure Ulcers

    NASA Astrophysics Data System (ADS)

    Mirchandani, Smruti Suresh

    Diffuse Reflectance Spectroscopy has been used widely to characterize tissue properties for diagnostic and therapeutic applications. This thesis focuses on the use of spectroscopy for early pressure ulcer detection. The most common early diagnosis technique for pressure ulcers is a blanch test. A major issue with a blanch test is that it is purely visual and cannot be visibly observed on dark skinned individuals. Studies have already proven that spectroscopy can be used to detect blanch response in skin across light and dark skinned individuals. The portable reflectance spectroscopy setup showed that pressure changes to the skin can be detected spectroscopically. Some work on an iPhone based spectrometer was also done to have a low-cost spectroscopy alternative to the usual DRS equipment. This study failed to develop an iPhone based spectrometer but various factors that can be changed to better this research have been mentioned in this thesis.

  10. Image manipulation software portable on different hardware platforms: what is the cost?

    NASA Astrophysics Data System (ADS)

    Ligier, Yves; Ratib, Osman M.; Funk, Matthieu; Perrier, Rene; Girard, Christian; Logean, Marianne

    1992-07-01

    A hospital wide PACS project is currently under development at the University Hospital of Geneva. The visualization and manipulation of images provided by different imaging modalities constitutes one of the most challenging components of a PACS. Because there are different requirements depending on the clinical usage, it was necessary for such a visualization software to be provided on different types of workstations in different sectors of the PACS. The user interface has to be the same independently of the underlying workstation. Beside, in addition to a standard set of image manipulation and processing tools there is a need for more specific clinical tools that should be easily adapted to specific medical requirements. To achieve operating and windowing systems: the standard Unix/X-11/OSF-Motif based workstations and the Macintosh family and should be easily ported on other systems. This paper describes the design of such a system and discusses the extra cost and efforts involved in the development of a portable and easily expandable software.

  11. Installing Portable Classrooms With Good Air Quality.

    ERIC Educational Resources Information Center

    Godfrey, Ray

    2000-01-01

    Discusses the advantages of modular classrooms and improvements made in indoor air quality, including the pros and cons of portables, challenges districts face when planning and installing portables, and cost considerations. Concluding comments highlight system costs and maintenance required. (GR)

  12. Development of a real-time microchip PCR system for portable plant disease diagnosis.

    PubMed

    Koo, Chiwan; Malapi-Wight, Martha; Kim, Hyun Soo; Cifci, Osman S; Vaughn-Diaz, Vanessa L; Ma, Bo; Kim, Sungman; Abdel-Raziq, Haron; Ong, Kevin; Jo, Young-Ki; Gross, Dennis C; Shim, Won-Bo; Han, Arum

    2013-01-01

    Rapid and accurate detection of plant pathogens in the field is crucial to prevent the proliferation of infected crops. Polymerase chain reaction (PCR) process is the most reliable and accepted method for plant pathogen diagnosis, however current conventional PCR machines are not portable and require additional post-processing steps to detect the amplified DNA (amplicon) of pathogens. Real-time PCR can directly quantify the amplicon during the DNA amplification without the need for post processing, thus more suitable for field operations, however still takes time and require large instruments that are costly and not portable. Microchip PCR systems have emerged in the past decade to miniaturize conventional PCR systems and to reduce operation time and cost. Real-time microchip PCR systems have also emerged, but unfortunately all reported portable real-time microchip PCR systems require various auxiliary instruments. Here we present a stand-alone real-time microchip PCR system composed of a PCR reaction chamber microchip with integrated thin-film heater, a compact fluorescence detector to detect amplified DNA, a microcontroller to control the entire thermocycling operation with data acquisition capability, and a battery. The entire system is 25 × 16 × 8 cm(3) in size and 843 g in weight. The disposable microchip requires only 8-µl sample volume and a single PCR run consumes 110 mAh of power. A DNA extraction protocol, notably without the use of liquid nitrogen, chemicals, and other large lab equipment, was developed for field operations. The developed real-time microchip PCR system and the DNA extraction protocol were used to successfully detect six different fungal and bacterial plant pathogens with 100% success rate to a detection limit of 5 ng/8 µl sample.

  13. Development of a Real-Time Microchip PCR System for Portable Plant Disease Diagnosis

    PubMed Central

    Kim, Hyun Soo; Cifci, Osman S.; Vaughn-Diaz, Vanessa L.; Ma, Bo; Kim, Sungman; Abdel-Raziq, Haron; Ong, Kevin; Jo, Young-Ki; Gross, Dennis C.; Shim, Won-Bo; Han, Arum

    2013-01-01

    Rapid and accurate detection of plant pathogens in the field is crucial to prevent the proliferation of infected crops. Polymerase chain reaction (PCR) process is the most reliable and accepted method for plant pathogen diagnosis, however current conventional PCR machines are not portable and require additional post-processing steps to detect the amplified DNA (amplicon) of pathogens. Real-time PCR can directly quantify the amplicon during the DNA amplification without the need for post processing, thus more suitable for field operations, however still takes time and require large instruments that are costly and not portable. Microchip PCR systems have emerged in the past decade to miniaturize conventional PCR systems and to reduce operation time and cost. Real-time microchip PCR systems have also emerged, but unfortunately all reported portable real-time microchip PCR systems require various auxiliary instruments. Here we present a stand-alone real-time microchip PCR system composed of a PCR reaction chamber microchip with integrated thin-film heater, a compact fluorescence detector to detect amplified DNA, a microcontroller to control the entire thermocycling operation with data acquisition capability, and a battery. The entire system is 25×16×8 cm3 in size and 843 g in weight. The disposable microchip requires only 8-µl sample volume and a single PCR run consumes 110 mAh of power. A DNA extraction protocol, notably without the use of liquid nitrogen, chemicals, and other large lab equipment, was developed for field operations. The developed real-time microchip PCR system and the DNA extraction protocol were used to successfully detect six different fungal and bacterial plant pathogens with 100% success rate to a detection limit of 5 ng/8 µl sample. PMID:24349341

  14. Development, Calibration and Evaluation of a Portable and Direct Georeferenced Laser Scanning System for Kinematic 3D Mapping

    NASA Astrophysics Data System (ADS)

    Heinz, Erik; Eling, Christian; Wieland, Markus; Klingbeil, Lasse; Kuhlmann, Heiner

    2015-12-01

    In recent years, kinematic laser scanning has become increasingly popular because it offers many benefits compared to static laser scanning. The advantages include both saving of time in the georeferencing and a more favorable scanning geometry. Often mobile laser scanning systems are installed on wheeled platforms, which may not reach all parts of the object. Hence, there is an interest in the development of portable systems, which remain operational even in inaccessible areas. The development of such a portable laser scanning system is presented in this paper. It consists of a lightweight direct georeferencing unit for the position and attitude determination and a small low-cost 2D laser scanner. This setup provides advantages over existing portable systems that employ heavy and expensive 3D laser scanners in a profiling mode. A special emphasis is placed on the system calibration, i. e. the determination of the transformation between the coordinate frames of the direct georeferencing unit and the 2D laser scanner. To this end, a calibration field is used, which consists of differently orientated georeferenced planar surfaces, leading to estimates for the lever arms and boresight angles with an accuracy of mm and one-tenth of a degree. Finally, point clouds of the mobile laser scanning system are compared with georeferenced point clouds of a high-precision 3D laser scanner. Accordingly, the accuracy of the system is in the order of cm to dm. This is in good agreement with the expected accuracy, which has been derived from the error propagation of previously estimated variance components.

  15. Portable Low Volume Therapy for Severe Blood Loss

    DTIC Science & Technology

    2016-08-01

    loss . 8 24-hour survival showed no statistical differences (p>0.05) between BHB/M (mean survival 21.0 ± 2.74 hrs) and 4 M BHB, 4.3 mM melatonin...in Figure 6 were compared 24 hours and 10 days after 60% blood loss . Pairwise comparisons are summarized in Table 3. No treatment differences were...Award Number: W81XWH-11-1-0409 TITLE: Portable Low-Volume Therapy for Severe Blood Loss PRINCIPAL INVESTIGATOR: Matthew T. Andrews CONTRACTING

  16. A multidisciplinary approach to the development of low-cost high-performance lightwave networks

    NASA Technical Reports Server (NTRS)

    Maitan, Jacek; Harwit, Alex

    1991-01-01

    Our research focuses on high-speed distributed systems. We anticipate that our results will allow the fabrication of low-cost networks employing multi-gigabit-per-second data links for space and military applications. The recent development of high-speed low-cost photonic components and new generations of microprocessors creates an opportunity to develop advanced large-scale distributed information systems. These systems currently involve hundreds of thousands of nodes and are made up of components and communications links that may fail during operation. In order to realize these systems, research is needed into technologies that foster adaptability and scaleability. Self-organizing mechanisms are needed to integrate a working fabric of large-scale distributed systems. The challenge is to fuse theory, technology, and development methodologies to construct a cost-effective, efficient, large-scale system.

  17. Portable and programmable clinical EOG diagnostic system.

    PubMed

    Chen, S C; Tsai, T T; Luo, C H

    2000-01-01

    Monitoring eye movements is clinically important in diagnosis of diseases of the central nervous system. Electrooculography (EOG) is one method of obtaining such records which uses skin electrodes, and utilizes the anterior posterior polarization of the eye. A new EOG diagnostic system has been developed that utilizes two off-the-shelf portable notebook computers, one projector and simple electronic hardware. It can be operated under Windows 95, 98, NT, and has significant advantages over any other similar equipment, including programmability, portability, improved safety and low cost. Especially, portability of the instrument is extremely important for acutely ill or handicapped patients. The purpose of this paper is to introduce the techniques of computer animation, data acquisition, real time analysis of measured data, and database management to implement a portable, programmable and inexpensive contacting EOG instrument. It is very convenient to replace the present expensive, inflexible and large-sized commercially available EOG instruments. A lot of interesting stimulation patterns for clinical application can be created easily in different shape, time sequence, and colour by programming in Delphi language. With the help of Winstar (a software package that is used to control I/O and interrupt functions of the computer under Windows 95, 98, NT), the I/O communication between two notebook computers and A/D interface module can be effectively programmed. In addition, the new EOG diagnostic system is battery operated and it has the advantages of low noise as well as isolation from electricity. Two kinds of EOG tests, pursuit and saccade, were performed on 20 normal subjects with this new portable and programmable instrument. Based on the test result, the performance of the new instrument is superior to the other commercially available instruments. In conclusion, we hope that it will be more convenient for doctors and researchers to do the clinical EOG diagnosis

  18. Determination of Thermal Transmittance of Insulated Double Low-E Glazing Panel Using Portable Uglass Measuring Technique

    NASA Astrophysics Data System (ADS)

    Kim, Inkoo; Frenzl, Alexander; Kim, Taehan; Min, Steven; Blumm, Jürgen

    2018-01-01

    Windows are regarded as the primary object of energy efficiency in buildings because window is one of the major energy loss areas in building construction. Existing methods were not field measurements and were not enough to get the correct thermal transmittance. We used portable Ug measuring device on field and measured the thermal transmittance with low-E coated and uncoated double glazing panels in existing houses, apartments and buildings. In addition, we prepared four test benches and compared the insulation performance according to the construction conditions. In results, the insulation performance of double glazing panel with low-E coating is up to about 41 % higher than uncoated panel due to low-E coating inside and the glazing panel filled with about 90 % of argon gas decrease about 0.15 W \\cdot m^{-2} \\cdot K^{-1} than glazing panel filled with air gas. The measured results were compared with the theoretically calculated results according to DIN EN 673 to confirm the reliability of the analytical results. In this study, portable NETZSCH Uglass is used to increase the accuracy of calculation of thermal transmittance with various double and triple glazing panels. The paper analyzes the insulation performance of the double glazing panels in accordance with the construction conditions.

  19. SkinScan©: A PORTABLE LIBRARY FOR MELANOMA DETECTION ON HANDHELD DEVICES

    PubMed Central

    Wadhawan, Tarun; Situ, Ning; Lancaster, Keith; Yuan, Xiaojing; Zouridakis, George

    2011-01-01

    We have developed a portable library for automated detection of melanoma termed SkinScan© that can be used on smartphones and other handheld devices. Compared to desktop computers, embedded processors have limited processing speed, memory, and power, but they have the advantage of portability and low cost. In this study we explored the feasibility of running a sophisticated application for automated skin cancer detection on an Apple iPhone 4. Our results demonstrate that the proposed library with the advanced image processing and analysis algorithms has excellent performance on handheld and desktop computers. Therefore, deployment of smartphones as screening devices for skin cancer and other skin diseases can have a significant impact on health care delivery in underserved and remote areas. PMID:21892382

  20. Low-cost commercial transport

    NASA Technical Reports Server (NTRS)

    Mcpherson, J.

    1991-01-01

    The topics presented are covered in viewgraph form. The objectives are to develop and validate technology, design tools and methodologies to enable the low cost commercial development and operational uses of hydrogen and hydrocarbon fueled liquid engines, low pressure booster engines and hybrid engines.

  1. Grading Multiple Choice Exams with Low-Cost and Portable Computer-Vision Techniques

    NASA Astrophysics Data System (ADS)

    Fisteus, Jesus Arias; Pardo, Abelardo; García, Norberto Fernández

    2013-08-01

    Although technology for automatic grading of multiple choice exams has existed for several decades, it is not yet as widely available or affordable as it should be. The main reasons preventing this adoption are the cost and the complexity of the setup procedures. In this paper, Eyegrade, a system for automatic grading of multiple choice exams is presented. While most current solutions are based on expensive scanners, Eyegrade offers a truly low-cost solution requiring only a regular off-the-shelf webcam. Additionally, Eyegrade performs both mark recognition as well as optical character recognition of handwritten student identification numbers, which avoids the use of bubbles in the answer sheet. When compared with similar webcam-based systems, the user interface in Eyegrade has been designed to provide a more efficient and error-free data collection procedure. The tool has been validated with a set of experiments that show the ease of use (both setup and operation), the reduction in grading time, and an increase in the reliability of the results when compared with conventional, more expensive systems.

  2. Low-cost mobile phone microscopy with a reversed mobile phone camera lens.

    PubMed

    Switz, Neil A; D'Ambrosio, Michael V; Fletcher, Daniel A

    2014-01-01

    The increasing capabilities and ubiquity of mobile phones and their associated digital cameras offer the possibility of extending low-cost, portable diagnostic microscopy to underserved and low-resource areas. However, mobile phone microscopes created by adding magnifying optics to the phone's camera module have been unable to make use of the full image sensor due to the specialized design of the embedded camera lens, exacerbating the tradeoff between resolution and field of view inherent to optical systems. This tradeoff is acutely felt for diagnostic applications, where the speed and cost of image-based diagnosis is related to the area of the sample that can be viewed at sufficient resolution. Here we present a simple and low-cost approach to mobile phone microscopy that uses a reversed mobile phone camera lens added to an intact mobile phone to enable high quality imaging over a significantly larger field of view than standard microscopy. We demonstrate use of the reversed lens mobile phone microscope to identify red and white blood cells in blood smears and soil-transmitted helminth eggs in stool samples.

  3. Low-Cost Mobile Phone Microscopy with a Reversed Mobile Phone Camera Lens

    PubMed Central

    Fletcher, Daniel A.

    2014-01-01

    The increasing capabilities and ubiquity of mobile phones and their associated digital cameras offer the possibility of extending low-cost, portable diagnostic microscopy to underserved and low-resource areas. However, mobile phone microscopes created by adding magnifying optics to the phone's camera module have been unable to make use of the full image sensor due to the specialized design of the embedded camera lens, exacerbating the tradeoff between resolution and field of view inherent to optical systems. This tradeoff is acutely felt for diagnostic applications, where the speed and cost of image-based diagnosis is related to the area of the sample that can be viewed at sufficient resolution. Here we present a simple and low-cost approach to mobile phone microscopy that uses a reversed mobile phone camera lens added to an intact mobile phone to enable high quality imaging over a significantly larger field of view than standard microscopy. We demonstrate use of the reversed lens mobile phone microscope to identify red and white blood cells in blood smears and soil-transmitted helminth eggs in stool samples. PMID:24854188

  4. Low-cost high purity production

    NASA Technical Reports Server (NTRS)

    Kapur, V. K.

    1978-01-01

    Economical process produces high-purity silicon crystals suitable for use in solar cells. Reaction is strongly exothermic and can be initiated at relatively low temperature, making it potentially suitable for development into low-cost commercial process. Important advantages include exothermic character and comparatively low process temperatures. These could lead to significant savings in equipment and energy costs.

  5. A low-cost and miniaturized potentiostat for sensing of biomolecular species such as TNF-α by electrochemical impedance spectroscopy.

    PubMed

    Pruna, Raquel; Palacio, Francisco; Baraket, Abdoullatif; Zine, Nadia; Streklas, Angelos; Bausells, Joan; Errachid, Abdelhamid; López, Manel

    2018-02-15

    Miniaturizing potentiostats, keeping their cost low and yet preserving full measurement characteristics (e.g. bandwidth, determination of capacitive/inductive contribution to sensor's impedance and parallel screening) is still an unresolved challenge in bioelectronics. In this work, the combination of simple analogue circuitry together with powerful microcontrollers and a digital filter implementation is presented as an alternative to complex and incomplete architectures reported in the literature. A low-cost acquisition electronic system fully integrated with a biosensors platform containing eight gold working microelectrodes and integrated reference and counter electrodes was developed and validated. The manufacturing cost of the prototype was kept below 300 USD. The performance of the proposed device was benchmarked against a commercial impedance analyzer through the electrochemical analysis of a highly sensitive biosensor for the detection of tumor necrosis factor α (TNF-α) within the randomly chosen range of 266pg/mL to 666ng/mL in physiological medium (PBS). A strong correlation between the outputs of both devices was found in a critical range of frequencies (1-10Hz), and several TNF-α cytokine concentrations were properly discriminated. These results are very promising for the development of low-cost, portable and miniaturized electrochemical systems for point-of-care and environmental diagnosis. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. Development and Applications of Portable Biosensors.

    PubMed

    Srinivasan, Balaji; Tung, Steve

    2015-08-01

    The significance of microfluidics-based and microelectromechanical systems-based biosensors has been widely acknowledged, and many reviews have explored their potential applications in clinical diagnostics, personalized medicine, global health, drug discovery, food safety, and forensics. Because health care costs are increasing, there is an increasing need to remotely monitor the health condition of patients by point-of-care-testing. The demand for biosensors for detection of biological warfare agents has increased, and research is focused on ways of producing small portable devices that would allow fast, accurate, and on-site detection. In the past decade, the demand for rapid and accurate on-site detection of plant disease diagnosis has increased due to emerging pathogens with resistance to pesticides, increased human mobility, and regulations limiting the application of toxic chemicals to prevent spread of diseases. The portability of biosensors for on-site diagnosis is limited due to various issues, including sample preparation techniques, fluid-handling techniques, the limited lifetime of biological reagents, device packaging, integrating electronics for data collection/analysis, and the requirement of external accessories and power. Many microfluidic, electronic, and biological design strategies, such as handling liquids in biosensors without pumps/valves, the application of droplet-based microfluidics, paper-based microfluidic devices, and wireless networking capabilities for data transmission, are being explored. © 2015 Society for Laboratory Automation and Screening.

  7. Image stacking approach to increase sensitivity of fluorescence detection using a low cost complementary metal-oxide-semiconductor (CMOS) webcam.

    PubMed

    Balsam, Joshua; Bruck, Hugh Alan; Kostov, Yordan; Rasooly, Avraham

    2012-01-01

    Optical technologies are important for biological analysis. Current biomedical optical analyses rely on high-cost, high-sensitivity optical detectors such as photomultipliers, avalanched photodiodes or cooled CCD cameras. In contrast, Webcams, mobile phones and other popular consumer electronics use lower-sensitivity, lower-cost optical components such as photodiodes or CMOS sensors. In order for consumer electronics devices, such as webcams, to be useful for biomedical analysis, they must have increased sensitivity. We combined two strategies to increase the sensitivity of CMOS-based fluorescence detector. We captured hundreds of low sensitivity images using a Webcam in video mode, instead of a single image typically used in cooled CCD devices.We then used a computational approach consisting of an image stacking algorithm to remove the noise by combining all of the images into a single image. While video mode is widely used for dynamic scene imaging (e.g. movies or time-lapse photography), it is not used to capture a single static image, which removes noise and increases sensitivity by more than thirty fold. The portable, battery-operated Webcam-based fluorometer system developed here consists of five modules: (1) a low cost CMOS Webcam to monitor light emission, (2) a plate to perform assays, (3) filters and multi-wavelength LED illuminator for fluorophore excitation, (4) a portable computer to acquire and analyze images, and (5) image stacking software for image enhancement. The samples consisted of various concentrations of fluorescein, ranging from 30 μM to 1000 μM, in a 36-well miniature plate. In the single frame mode, the fluorometer's limit-of-detection (LOD) for fluorescein is ∼1000 μM, which is relatively insensitive. However, when used in video mode combined with image stacking enhancement, the LOD is dramatically reduced to 30 μM, sensitivity which is similar to that of state-of-the-art ELISA plate photomultiplier-based readers. Numerous medical

  8. Image stacking approach to increase sensitivity of fluorescence detection using a low cost complementary metal-oxide-semiconductor (CMOS) webcam

    PubMed Central

    Balsam, Joshua; Bruck, Hugh Alan; Kostov, Yordan; Rasooly, Avraham

    2013-01-01

    Optical technologies are important for biological analysis. Current biomedical optical analyses rely on high-cost, high-sensitivity optical detectors such as photomultipliers, avalanched photodiodes or cooled CCD cameras. In contrast, Webcams, mobile phones and other popular consumer electronics use lower-sensitivity, lower-cost optical components such as photodiodes or CMOS sensors. In order for consumer electronics devices, such as webcams, to be useful for biomedical analysis, they must have increased sensitivity. We combined two strategies to increase the sensitivity of CMOS-based fluorescence detector. We captured hundreds of low sensitivity images using a Webcam in video mode, instead of a single image typically used in cooled CCD devices.We then used a computational approach consisting of an image stacking algorithm to remove the noise by combining all of the images into a single image. While video mode is widely used for dynamic scene imaging (e.g. movies or time-lapse photography), it is not used to capture a single static image, which removes noise and increases sensitivity by more than thirty fold. The portable, battery-operated Webcam-based fluorometer system developed here consists of five modules: (1) a low cost CMOS Webcam to monitor light emission, (2) a plate to perform assays, (3) filters and multi-wavelength LED illuminator for fluorophore excitation, (4) a portable computer to acquire and analyze images, and (5) image stacking software for image enhancement. The samples consisted of various concentrations of fluorescein, ranging from 30 μM to 1000 μM, in a 36-well miniature plate. In the single frame mode, the fluorometer's limit-of-detection (LOD) for fluorescein is ∼1000 μM, which is relatively insensitive. However, when used in video mode combined with image stacking enhancement, the LOD is dramatically reduced to 30 μM, sensitivity which is similar to that of state-of-the-art ELISA plate photomultiplier-based readers. Numerous medical

  9. Development of low-cost silicon crystal growth techniques for terrestrial photovoltaic solar energy conversion

    NASA Technical Reports Server (NTRS)

    Zoutendyk, J. A.

    1976-01-01

    Because of the growing need for new sources of electrical energy, photovoltaic solar energy conversion is being developed. Photovoltaic devices are now being produced mainly from silicon wafers obtained from the slicing and polishing of cylindrically shaped single crystal ingots. Inherently high-cost processes now being used must either be eliminated or modified to provide low-cost crystalline silicon. Basic to this pursuit is the development of new or modified methods of crystal growth and, if necessary, crystal cutting. If silicon could be grown in a form requiring no cutting, a significant cost saving would potentially be realized. Therefore, several techniques for growth in the form of ribbons or sheets are being explored. In addition, novel techniques for low-cost ingot growth and cutting are under investigation.

  10. Low-Hanging Fruit: How Boards Can Improve Education Now through Pedagogy, Portability, and Price

    ERIC Educational Resources Information Center

    Smith, Peter

    2011-01-01

    Boards do not have to wait for coming reforms to improve pricing and academic structure for students. They can have a significant impact immediately by making recognized learning portable, simplifying pricing, and reducing costs to students. Developmental education, blended and online learning, and adaptive learning are being touted as…

  11. Development of an ultra-portable ride quality meter.

    DOT National Transportation Integrated Search

    2012-12-01

    FRAs Office of Research and Development has funded the development of an ultra-portable ride quality meter (UPRQM) under the Small Business and Innovative Research (SBIR) program. Track inspectors can use the UPRQM to locate segments of track that...

  12. Portable and Error-Free DNA-Based Data Storage.

    PubMed

    Yazdi, S M Hossein Tabatabaei; Gabrys, Ryan; Milenkovic, Olgica

    2017-07-10

    DNA-based data storage is an emerging nonvolatile memory technology of potentially unprecedented density, durability, and replication efficiency. The basic system implementation steps include synthesizing DNA strings that contain user information and subsequently retrieving them via high-throughput sequencing technologies. Existing architectures enable reading and writing but do not offer random-access and error-free data recovery from low-cost, portable devices, which is crucial for making the storage technology competitive with classical recorders. Here we show for the first time that a portable, random-access platform may be implemented in practice using nanopore sequencers. The novelty of our approach is to design an integrated processing pipeline that encodes data to avoid costly synthesis and sequencing errors, enables random access through addressing, and leverages efficient portable sequencing via new iterative alignment and deletion error-correcting codes. Our work represents the only known random access DNA-based data storage system that uses error-prone nanopore sequencers, while still producing error-free readouts with the highest reported information rate/density. As such, it represents a crucial step towards practical employment of DNA molecules as storage media.

  13. Development of a portable Linux-based ECG measurement and monitoring system.

    PubMed

    Tan, Tan-Hsu; Chang, Ching-Su; Huang, Yung-Fa; Chen, Yung-Fu; Lee, Cheng

    2011-08-01

    This work presents a portable Linux-based electrocardiogram (ECG) signals measurement and monitoring system. The proposed system consists of an ECG front end and an embedded Linux platform (ELP). The ECG front end digitizes 12-lead ECG signals acquired from electrodes and then delivers them to the ELP via a universal serial bus (USB) interface for storage, signal processing, and graphic display. The proposed system can be installed anywhere (e.g., offices, homes, healthcare centers and ambulances) to allow people to self-monitor their health conditions at any time. The proposed system also enables remote diagnosis via Internet. Additionally, the system has a 7-in. interactive TFT-LCD touch screen that enables users to execute various functions, such as scaling a single-lead or multiple-lead ECG waveforms. The effectiveness of the proposed system was verified by using a commercial 12-lead ECG signal simulator and in vivo experiments. In addition to its portability, the proposed system is license-free as Linux, an open-source code, is utilized during software development. The cost-effectiveness of the system significantly enhances its practical application for personal healthcare.

  14. Coping With Spatial Attention in Real Space: A Low-Cost Portable Testing System for the Investigation of Visuo-Spatial Processing in the Human Brain

    PubMed Central

    Wolfe, Benjamin; Rushmore, Richard J.; Valero-Cabré, Antoni

    2010-01-01

    While two-dimensional stimuli may be easily presented with any computer, an apparatus which allows a range of stimuli to be presented in three dimensions is not easily or cheaply available to researchers or clinicians. To fill this gap, we have developed the Realspace Testing System (RTS) which addresses the need for a flexible and multimodal stimulus presentation system capable of displaying stimuli in a three dimensional space with a high degree of temporal accuracy. The RTS is able to control twenty-six channels of visual or audio stimuli, to send trigger pulses during each trial to external devices, such as a Transcranial Magnetic Stimulator, and to record subject responses during the testing sessions. The RTS is flexible, portable and can be used in laboratory or clinical settings as required while being built at a low cost using off the shelf components. We have tested the RTS by performing an exploratory experiment on the role of right posterior parietal cortex in visuospatial processing in conjunction with online Transcranial Magnetic Stimulation (TMS) and verified that the system can accurately present stimuli as needed while triggering a TMS pulse during each trial at the required time. The RTS could be appealing and useful to a range of researchers or clinicians who may choose to use it much as we have designed it, or use it in its current state as a starting point to customize their stimulus control systems in real space. PMID:20079374

  15. Development of a Portable Knee Rehabilitation Device That Uses Mechanical Loading.

    PubMed

    Fitzwater, Daric; Dodge, Todd; Chien, Stanley; Yokota, Hiroki; Anwar, Sohel

    2013-12-01

    Joint loading is a recently developed mechanical modality, which potentially provides a therapeutic regimen to activate bone formation and prevent degradation of joint tissues. To our knowledge, however, few joint loading devices are available for clinical or point-of-care applications. Using a voice-coil actuator, we developed an electromechanical loading system appropriate for human studies and preclinical trials that should prove both safe and effective. Two specific tasks for this loading system were development of loading conditions (magnitude and frequency) suitable for humans, and provision of a convenient and portable joint loading apparatus. Desktop devices have been previously designed to evaluate the effects of various loading conditions using small and large animals. However, a portable knee loading device is more desirable from a usability point of view. In this paper, we present such a device that is designed to be portable, providing a compact, user-friendly loader. The portable device was employed to evaluate its capabilities using a human knee model. The portable device was characterized for force-pulse width modulation duty cycle and loading frequency properties. The results demonstrate that the device is capable of producing the necessary magnitude of forces at appropriate frequencies to promote the stimulation of bone growth and which can be used in clinical studies for further evaluations.

  16. Improved low-cost, non-hazardous, all-iron cell for the developing world

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tucker, Michael C.; Lambelet, David; Oueslati, Mohamed

    A low-cost, non-hazardous personal-power system based on an aqueous all-iron electrochemical cell is demonstrated in this paper. The system is intended to be assembled and operated by developing-world households that lack sufficient access to electricity, thereby enabling LED lighting or mobile phone charging on demand. Lab-scale hardware is used to assess the performance of individual cell components. It is found that coffee filter paper is an effective low-cost separator. Carbon felt is a low-cost electrode material, and its performance and wetting by the electrolyte solution is greatly improved by pre-treatment with sulfuric acid. The carbon felt does not degrade aftermore » a week of daily use. By using these components, performance of the system is significantly improved over the previous baseline, with power density more than doubling to 40 mW cm -2, and iron utilization improving from 78% to 88%. The operating cost is estimated to be less than US$0.03 per mobile phone charge. Based on the lab-scale results, a stand-alone prototype consumer product is designed, fabricated, and tested. It successfully provides 2.5 h of LED illumination while consuming 200 mL of electrolyte solution via gravity feed. Finally, we anticipate these results will enable deployment of this innovative system to energy-impoverished individuals in the developing world.« less

  17. Improved low-cost, non-hazardous, all-iron cell for the developing world

    NASA Astrophysics Data System (ADS)

    Tucker, Michael C.; Lambelet, David; Oueslati, Mohamed; Williams, Benjamin; Wang, Wu-Chieh Jerry; Weber, Adam Z.

    2016-11-01

    A low-cost, non-hazardous personal-power system based on an aqueous all-iron electrochemical cell is demonstrated. The system is intended to be assembled and operated by developing-world households that lack sufficient access to electricity, thereby enabling LED lighting or mobile phone charging on demand. Lab-scale hardware is used to assess the performance of individual cell components. It is found that coffee filter paper is an effective low-cost separator. Carbon felt is a low-cost electrode material, and its performance and wetting by the electrolyte solution is greatly improved by pre-treatment with sulfuric acid. The carbon felt does not degrade after a week of daily use. By using these components, performance of the system is significantly improved over the previous baseline, with power density more than doubling to 40 mW cm-2, and iron utilization improving from 78% to 88%. The operating cost is estimated to be less than US0.03 per mobile phone charge. Based on the lab-scale results, a stand-alone prototype consumer product is designed, fabricated, and tested. It successfully provides 2.5 h of LED illumination while consuming 200 mL of electrolyte solution via gravity feed. We anticipate these results will enable deployment of this innovative system to energy-impoverished individuals in the developing world.

  18. Improved low-cost, non-hazardous, all-iron cell for the developing world

    DOE PAGES

    Tucker, Michael C.; Lambelet, David; Oueslati, Mohamed; ...

    2016-09-28

    A low-cost, non-hazardous personal-power system based on an aqueous all-iron electrochemical cell is demonstrated in this paper. The system is intended to be assembled and operated by developing-world households that lack sufficient access to electricity, thereby enabling LED lighting or mobile phone charging on demand. Lab-scale hardware is used to assess the performance of individual cell components. It is found that coffee filter paper is an effective low-cost separator. Carbon felt is a low-cost electrode material, and its performance and wetting by the electrolyte solution is greatly improved by pre-treatment with sulfuric acid. The carbon felt does not degrade aftermore » a week of daily use. By using these components, performance of the system is significantly improved over the previous baseline, with power density more than doubling to 40 mW cm -2, and iron utilization improving from 78% to 88%. The operating cost is estimated to be less than US$0.03 per mobile phone charge. Based on the lab-scale results, a stand-alone prototype consumer product is designed, fabricated, and tested. It successfully provides 2.5 h of LED illumination while consuming 200 mL of electrolyte solution via gravity feed. Finally, we anticipate these results will enable deployment of this innovative system to energy-impoverished individuals in the developing world.« less

  19. Development of Low Cost Satellite Communications System for Helicopters and General Aviation

    NASA Technical Reports Server (NTRS)

    Farazian, K.; Abbe, B.; Divsalar, D.; Raphaeli, D.; Tulintseff, A.; Wu, T.; Hinedi, S.

    1994-01-01

    In this paper, the development of low-cost satellite communications (SATCOM) system for helicopters and General Aviation (GA) aircrafts is described. System design and standards analysis have been conducted to meet the low-cost, light-weight, small-size and low-power system requirements for helicopters and GA aircraft environments. Other specific issues investigated include coding schemes, spatial diversity, and antenna arraying techniques. Coding schemes employing Channel State Information (CSI) and inverleaving have been studied in order to mitigate severe banking angle fading and the periodic RF signal blockage due to the helicopter rotor blades. In addition, space diversity and antenna arraying techniques have been investigated to further reduce the fading effects and increase the link margin.

  20. Development of low cost contacts to silicon solar cells

    NASA Technical Reports Server (NTRS)

    Tanner, D. P.

    1980-01-01

    The results of the second phase of the program of developing low cost contacts to silicon solar cells using copper are presented. Phase 1 yielded the development of a plated Pd-Cr-Cu contact system. This process produced cells with shunting problems when they were heated to 400 C for 5 minutes. Means of stopping the identified copper diffusion which caused the shunting were investigated. A contact heat treatment study was conducted with Pd-Ag, Ci-Ag, Pd-Cu, Cu-Cr, and Ci-Ni-Cu. Nickel is shown to be an effective diffusion barrier to copper.

  1. Development of Low-cost plotter for educational purposes using Arduino

    NASA Astrophysics Data System (ADS)

    Karthik, Siriparapu; Thirumal Reddy, Palwai; Marimuthu, K. Prakash

    2017-08-01

    With the development of CAD/CAM/CAE concept to product realization time has reduced drastically. Most of the activities such as design, drafting, and visualizations are carried out using high-end computers and commercial software. This has reduced the overall lead-time to market. It is important in the current scenario to equip the students with knowledge of advanced technological developments in order to use them effectively. However, the cost associated with the systems are very high which is not affordable to students. The present work is an attempt to build a low-cost plotter integrating some of the software that are available and components got from scrapped electronic devices. Here the authors are introducing G-code plotter with 3-axis which can implement the given g-code in 2D plane (X-Y). Lifting pen and adjusting to the base component is in the Z-axis. All conventional plotting devices existing until date are costly and need basic knowledge before operating. Our aim is to make students understand the working of plotter and the usage of G-code, achieving this at a much affordable cost. Arduino Uno controls the stepper motors, which can accurately plot the given dimensions.

  2. 48 CFR 1852.237-71 - Pension portability.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 48 Federal Acquisition Regulations System 6 2010-10-01 2010-10-01 true Pension portability. 1852... 1852.237-71 Pension portability. As prescribed at 1837.110-70(b), insert the following clause: Pension Portability (JAN 1997) (a) In order for pension costs attributable to employees assigned to this contract to...

  3. Low-Cost Hydrogen Distributed Production System Development

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    C.E.

    2011-03-10

    H{sub 2}Gen, with the support of the Department of Energy, successfully designed, built and field-tested two steam methane reformers with 578 kg/day capacity, which has now become a standard commercial product serving customers in the specialty metals and PV manufacturing businesses. We demonstrated that this reformer/PSA system, when combined with compression, storage and dispensing (CSD) equipment could produce hydrogen that is already cost-competitive with gasoline per mile driven in a conventional (non-hybrid) vehicle. We further showed that mass producing this 578 kg/day system in quantities of just 100 units would reduce hydrogen cost per mile approximately 13% below the cost of untaxed gasoline per mile used in a hybrid electric vehicle. If mass produced in quantities of 500 units, hydrogen cost per mile in a FCEV would be 20% below the cost of untaxed gasoline in an HEV in the 2015-2020 time period using EIA fuel cost projections for natural gas and untaxed gasoline, and 45% below the cost of untaxed gasoline in a conventional car. This 20% to 45% reduction in fuel cost per mile would accrue even though hydrogen from this 578 kg/day system would cost approximatelymore » $4.14/kg, well above the DOE hydrogen cost targets of $2.50/kg by 2010 and $$2.00/kg by 2015. We also estimated the cost of a larger, 1,500 kg/day SMR/PSA fueling system based on engineering cost scaling factors derived from the two H{sub 2}Gen products, a commercial 115 kg/day system and the 578 kg/day system developed under this DOE contract. This proposed system could support 200 to 250 cars per day, similar to a medium gasoline station. We estimate that the cost per mile from this larger 1,500 kg/day hydrogen fueling system would be 26% to 40% below the cost per mile of untaxed gasoline in an HEV and ICV respectively, even without any mass production cost reductions. In quantities of 500 units, we are projecting per mile cost reductions between 45% (vs. HEVs) and 62% (vs ICVs), with

  4. One-port portable SAW sensor system

    NASA Astrophysics Data System (ADS)

    Hoa Nguyen, Vu; Peters, Oliver; Schnakenberg, Uwe

    2018-01-01

    A portable device using the SAW-based impedance sensor type based on one interdigital transducer simultaneously as SAW generator and sensor element (1-port approach) is introduced. As a novelty, the so far required expensive vector network analyzer (VNA) is replaced by a hand-held device to measure the impedance spectrum of the SAW sensor by RF-gain-phase meters. Hence, some of the best features from the conventional oscillator and VNA approaches are combined to develop a low-cost and self-contained measurement system, including signal in- and output ability for real-time measurements. The pivotal aspect of the portable system is the transfer of the sophisticated high frequency approach into a quasi-static one. This enables the use of simple lumped electronics without the need of impedance matching circuits. Proof-of-concept was carried out by measuring conductivities of phosphate-buffered solutions and viscosities of glycerin. Sensitivities for temperature of 0.3%/°C, viscosity of 10.1% (mPa s)-1 and conductivity of 0.5% (S cm)-1 have been determined, respectively, which are competitive results compared to the benchmark approaches.

  5. 30 CFR 77.900 - Low- and medium-voltage circuits serving portable or mobile three-phase alternating current...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... portable or mobile three-phase alternating current equipment; circuit breakers. 77.900 Section 77.900... mobile three-phase alternating current equipment; circuit breakers. Low- and medium-voltage circuits supplying power to portable or mobile three-phase alternating current equipment shall be protected by...

  6. Solid Sampling with a Diode Laser for Portable Ambient Mass Spectrometry.

    PubMed

    Yung, Yeni P; Wickramasinghe, Raveendra; Vaikkinen, Anu; Kauppila, Tiina J; Veryovkin, Igor V; Hanley, Luke

    2017-07-18

    A hand-held diode laser is implemented for solid sampling in portable ambient mass spectrometry (MS). Specifically, a pseudocontinuous wave battery-powered surgical laser diode is employed for portable laser diode thermal desorption (LDTD) at 940 nm and compared with nanosecond pulsed laser ablation at 2940 nm. Postionization is achieved in both cases using atmospheric pressure photoionization (APPI). The laser ablation atmospheric pressure photoionization (LAAPPI) and LDTD-APPI mass spectra of sage leaves (Salvia officinalis) using a field-deployable quadrupole ion trap MS display many similar ion peaks, as do the mass spectra of membrane grown biofilms of Pseudomonas aeruginosa. These results indicate that LDTD-APPI method should be useful for in-field sampling of plant and microbial communities, for example, by portable ambient MS. The feasibility of many portable MS applications is facilitated by the availability of relatively low cost, portable, battery-powered diode lasers. LDTD could also be coupled with plasma- or electrospray-based ionization for the analysis of a variety of solid samples.

  7. Developing a low-cost open-source CTD for research and outreach

    NASA Astrophysics Data System (ADS)

    Thaler, A. D.; Sturdivant, K.

    2013-12-01

    Developing a low-cost open-source CTD for research and outreach Andrew David Thaler and Kersey Sturdivant Conductivity, temperature, and depth (CTD). With these three measurements, marine scientists can unlock ocean patterns hidden beneath the waves. The ocean is not uniform, it its filled with swirling eddies, temperature boundaries, layers of high and low salinity, changing densities, and many other physical characteristics. To reveal these patterns, oceanographers use a tool called the CTD. A CTD is found on almost every major research vessel. Rare is the scientific expedition-whether it be coastal work in shallow estuaries or journeys to the deepest ocean trenches-that doesn't begin with the humble CTD cast. The CTD is not cheap. Commercial CTD's start at more the 5,000 and can climb as high as 25,000 or more. We believe that the prohibitive cost of a CTD is an unacceptable barrier to open science. The price tag excludes individuals and groups who lack research grants or significant private funds from conducting oceanographic research. We want to make this tool-the workhorse of oceanographic research-available to anyone with an interest in the oceans. The OpenCTD is a low-cost, open-source CTD suitable for both educators and scientists. The platform is built using readily available parts and is powered by an Arduino-based microcontroller. Our goal is to create a device that is accurate enough to be used for scientific research and can be constructed for less than $200. Source codes, circuit diagrams, and building plans will be freely available. The final instrument will be effective to 200 meters depth. Why 200 meters? For many coastal regions, 200 meters of water depth covers the majority of the ocean that is accessible by small boat. The OpenCTD is targeted to people working in this niche, where entire research projects can be conducted for less than the cost of a commercial CTD. However, the Open CTD is scalable, and anyone with the inclination can adapt our

  8. High performance 3D adaptive filtering for DSP based portable medical imaging systems

    NASA Astrophysics Data System (ADS)

    Bockenbach, Olivier; Ali, Murtaza; Wainwright, Ian; Nadeski, Mark

    2015-03-01

    Portable medical imaging devices have proven valuable for emergency medical services both in the field and hospital environments and are becoming more prevalent in clinical settings where the use of larger imaging machines is impractical. Despite their constraints on power, size and cost, portable imaging devices must still deliver high quality images. 3D adaptive filtering is one of the most advanced techniques aimed at noise reduction and feature enhancement, but is computationally very demanding and hence often cannot be run with sufficient performance on a portable platform. In recent years, advanced multicore digital signal processors (DSP) have been developed that attain high processing performance while maintaining low levels of power dissipation. These processors enable the implementation of complex algorithms on a portable platform. In this study, the performance of a 3D adaptive filtering algorithm on a DSP is investigated. The performance is assessed by filtering a volume of size 512x256x128 voxels sampled at a pace of 10 MVoxels/sec with an Ultrasound 3D probe. Relative performance and power is addressed between a reference PC (Quad Core CPU) and a TMS320C6678 DSP from Texas Instruments.

  9. Enzyme-Encapsulated Liposome-Linked Immunosorbent Assay Enabling Sensitive Personal Glucose Meter Readout for Portable Detection of Disease Biomarkers.

    PubMed

    Lin, Bingqian; Liu, Dan; Yan, Jinmao; Qiao, Zhi; Zhong, Yunxin; Yan, Jiawei; Zhu, Zhi; Ji, Tianhai; Yang, Chaoyong James

    2016-03-23

    There is considerable demand for sensitive, selective, and portable detection of disease-associated proteins, particularly in clinical practice and diagnostic applications. Portable devices are highly desired for detection of disease biomarkers in daily life due to the advantages of being simple, rapid, user-friendly, and low-cost. Herein we report an enzyme-encapsulated liposome-linked immunosorbent assay for sensitive detection of proteins using personal glucose meters (PGM) for portable quantitative readout. Liposomes encapsulating a large amount of amyloglucosidase or invertase are surface-coated with recognition elements such as aptamers or antibodies for target recognition. By translating molecular recognition signal into a large amount of glucose with the encapsulated enzyme, disease biomarkers such as thrombin or C-reactive protein (CRP) can be quantitatively detected by a PGM with a high detection limit of 1.8 or 0.30 nM, respectively. With the advantages of portability, ease of use, and low-cost, the method reported here has potential for portable and quantitative detection of various targets for different POC testing scenarios, such as rapid diagnosis in clinic offices, health monitoring at the bedside, and chemical/biochemical safety control in the field.

  10. Development and evaluation of low-cost walker with trunk support for senior citizen.

    PubMed

    Poier, Paloma Hohmann; Godke, Francisco; Foggiatto, José Aguiomar; Ulbricht, Leandra

    2017-10-09

    Develop and evaluate a low-cost walker with trunk support for senior citizens. Two-stage descriptive study: development of a walker with trunk support and evaluation with fourth age senior citizens. Twenty-three fourth age senior citizens were selected. The evaluated criteria were the immediate influence of the walker on the static stabilometry with baropodometer and the evaluation of gait with accelerometers monitoring time and amplitude of the hip movement. There was a significant decrease in the body oscillation of senior citizens with the use of the developed walker, and there were changes in the joint amplitudes of the hip, but they were not significant. Using low-cost materials, it was possible to develop and equipment that met resistance and effectiveness requirements. The walker interfered in the balance of the senior citizens, reducing significantly the static body oscillation.

  11. Development of Universal Portable Spray Stand for Touch-Up Process in The Automotive Paintshop

    NASA Astrophysics Data System (ADS)

    Fatah Muhamed Mukhtar, Muhamed Abdul; Mohideen Shahul Hameed, Rasool

    2016-02-01

    A spray stand is a custom-made tool used to hold the automotive body parts as well as the devices used to facilitate the operator during the Touch Up process in Paint shop production. This paper discusses about the development of Universal Portable Spray Stand (UPSS) as a tool to hold various types of automotive body parts and model of car during the painting process. The main objective of this study is to determine the effective application of UPSS at the International College of Automotive (ICAM) and also in the automotive industry. This will be helpful to add features to the current spray stand in ICAM and to add value to the spray stand based on selected criteria which are universal, portable and cost saving. In addition, study in the UPSS is also expected to bring reduction in cycle time during the touch up process, in the paint defects and in the ergonomics issues among the operators.

  12. The Economics of Educational Software Portability.

    ERIC Educational Resources Information Center

    Oliveira, Joao Batista Araujo e

    1990-01-01

    Discusses economic issues that affect the portability of educational software. Topics discussed include economic reasons for portability, including cost effectiveness; the nature and behavior of educational computer software markets; the role of producers, buyers, and consumers; potential effects of government policies; computer piracy; and…

  13. Field portable low temperature porous layer open tubular cryoadsorption headspace sampling and analysis part II: Applications.

    PubMed

    Harries, Megan; Bukovsky-Reyes, Santiago; Bruno, Thomas J

    2016-01-15

    This paper details the sampling methods used with the field portable porous layer open tubular cryoadsorption (PLOT-cryo) approach, described in Part I of this two-part series, applied to several analytes of interest. We conducted tests with coumarin and 2,4,6-trinitrotoluene (two solutes that were used in initial development of PLOT-cryo technology), naphthalene, aviation turbine kerosene, and diesel fuel, on a variety of matrices and test beds. We demonstrated that these analytes can be easily detected and reliably identified using the portable unit for analyte collection. By leveraging efficiency-boosting temperature control and the high flow rate multiple capillary wafer, very short collection times (as low as 3s) yielded accurate detection. For diesel fuel spiked on glass beads, we determined a method detection limit below 1 ppm. We observed greater variability among separate samples analyzed with the portable unit than previously documented in work using the laboratory-based PLOT-cryo technology. We identify three likely sources that may help explain the additional variation: the use of a compressed air source to generate suction, matrix geometry, and variability in the local vapor concentration around the sampling probe as solute depletion occurs both locally around the probe and in the test bed as a whole. This field-portable adaptation of the PLOT-cryo approach has numerous and diverse potential applications. Published by Elsevier B.V.

  14. Field Portable Low Temperature Porous Layer Open Tubular Cryoadsorption Headspace Sampling and Analysis Part II: Applications*

    PubMed Central

    Harries, Megan; Bukovsky-Reyes, Santiago; Bruno, Thomas J.

    2016-01-01

    This paper details the sampling methods used with the field portable porous layer open tubular cryoadsorption (PLOT-cryo) approach, described in Part I of this two-part series, applied to several analytes of interest. We conducted tests with coumarin and 2,4,6-trinitrotoluene (two solutes that were used in initial development of PLOT-cryo technology), naphthalene, aviation turbine kerosene, and diesel fuel, on a variety of matrices and test beds. We demonstrated that these analytes can be easily detected and reliably identified using the portable unit for analyte collection. By leveraging efficiency-boosting temperature control and the high flow rate multiple capillary wafer, very short collection times (as low as 3 s) yielded accurate detection. For diesel fuel spiked on glass beads, we determined a method detection limit below 1 ppm. We observed greater variability among separate samples analyzed with the portable unit than previously documented in work using the laboratory-based PLOT-cryo technology. We identify three likely sources that may help explain the additional variation: the use of a compressed air source to generate suction, matrix geometry, and variability in the local vapor concentration around the sampling probe as solute depletion occurs both locally around the probe and in the test bed as a whole. This field-portable adaptation of the PLOT-cryo approach has numerous and diverse potential applications. PMID:26726934

  15. Low-Cost High-Performance MRI

    NASA Astrophysics Data System (ADS)

    Sarracanie, Mathieu; Lapierre, Cristen D.; Salameh, Najat; Waddington, David E. J.; Witzel, Thomas; Rosen, Matthew S.

    2015-10-01

    Magnetic Resonance Imaging (MRI) is unparalleled in its ability to visualize anatomical structure and function non-invasively with high spatial and temporal resolution. Yet to overcome the low sensitivity inherent in inductive detection of weakly polarized nuclear spins, the vast majority of clinical MRI scanners employ superconducting magnets producing very high magnetic fields. Commonly found at 1.5-3 tesla (T), these powerful magnets are massive and have very strict infrastructure demands that preclude operation in many environments. MRI scanners are costly to purchase, site, and maintain, with the purchase price approaching $1 M per tesla (T) of magnetic field. We present here a remarkably simple, non-cryogenic approach to high-performance human MRI at ultra-low magnetic field, whereby modern under-sampling strategies are combined with fully-refocused dynamic spin control using steady-state free precession techniques. At 6.5 mT (more than 450 times lower than clinical MRI scanners) we demonstrate (2.5 × 3.5 × 8.5) mm3 imaging resolution in the living human brain using a simple, open-geometry electromagnet, with 3D image acquisition over the entire brain in 6 minutes. We contend that these practical ultra-low magnetic field implementations of MRI (<10 mT) will complement traditional MRI, providing clinically relevant images and setting new standards for affordable (<$50,000) and robust portable devices.

  16. Biosensors and bioelectronics on smartphone for portable biochemical detection.

    PubMed

    Zhang, Diming; Liu, Qingjun

    2016-01-15

    Smartphone has been widely integrated with sensors, such as test strips, sensor chips, and hand-held detectors, for biochemical detections due to its portability and ubiquitous availability. Utilizing built-in function modules, smartphone is often employed as controller, analyzer, and displayer for rapid, real-time, and point-of-care monitoring, which can significantly simplify design and reduce cost of the detecting systems. This paper presents a review of biosensors and bioelectronics on smartphone for portable biochemical detections. The biosensors and bioelectronics based on smartphone can mainly be classified into biosensors using optics, surface plasmon resonance, electrochemistry, and near-field communication. The developments of these biosensors and bioelectronics on smartphone are reviewed along with typical biochemical detecting cases. Sensor strategies, detector attachments, and coupling methods are highlighted to show designs of the compact, lightweight, and low-cost sensor systems. The performances and advantages of these designs are introduced with their applications in healthcare diagnosis, environment monitoring, and food evaluation. With advances in micro-manufacture, sensor technology, and miniaturized electronics, biosensor and bioelectronic devices on smartphone can be used to perform biochemical detections as common and convenient as electronic tag readout in foreseeable future. Copyright © 2015 Elsevier B.V. All rights reserved.

  17. Handheld probe for portable high frame photoacoustic/ultrasound imaging system

    NASA Astrophysics Data System (ADS)

    Daoudi, K.; van den Berg, P. J.; Rabot, O.; Kohl, A.; Tisserand, S.; Brands, P.; Steenbergen, W.

    2013-03-01

    Photoacoustics is a hybrid imaging modality that is based on the detection of acoustic waves generated by absorption of pulsed light by tissue chromophors. In current research, this technique uses large and costly photoacoustic systems with a low frame rate imaging. To open the door for widespread clinical use, a compact, cost effective and fast system is required. In this paper we report on the development of a small compact handset pulsed laser probe which will be connected to a portable ultrasound system for real-time photoacoustic imaging and ultrasound imaging. The probe integrates diode lasers driven by an electrical driver developed for very short high power pulses. It uses specifically developed highly efficient diode stacks with high frequency repetition rate up to 10 kHz, emitting at 800nm wavelength. The emitted beam is collimated and shaped with compact micro optics beam shaping system delivering a homogenized rectangular laser beam intensity distribution. The laser block is integrated with an ultrasound transducer in an ergonomically designed handset probe. This handset is a building block enabling for a low cost high frame rate photoacoustic and ultrasound imaging system. The probe was used with a modified ultrasound scanner and was tested by imaging a tissue mimicking phantom.

  18. Development of fast neutron radiography system based on portable neutron generator

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yi, Chia Jia, E-mail: gei-i-kani@hotmail.com; Nilsuwankosit, Sunchai, E-mail: sunchai.n@chula.ac.th

    Due to the high installation cost, the safety concern and the immobility of the research reactors, the neutron radiography system based on portable neutron generator is proposed. Since the neutrons generated from a portable neutron generator are mostly the fast neutrons, the system is emphasized on using the fast neutrons for the purpose of conducting the radiography. In order to suppress the influence of X-ray produced by the neutron generator, a combination of a shielding material sandwiched between two identical imaging plates is used. A binary XOR operation is then applied for combining the information from the imaging plates. Themore » raw images obtained confirm that the X-ray really has a large effect and that XOR operation can help enhance the effect of the neutrons.« less

  19. Noise Source Visualization Using a Digital Voice Recorder and Low-Cost Sensors

    PubMed Central

    Cho, Yong Thung

    2018-01-01

    Accurate sound visualization of noise sources is required for optimal noise control. Typically, noise measurement systems require microphones, an analog-digital converter, cables, a data acquisition system, etc., which may not be affordable for potential users. Also, many such systems are not highly portable and may not be convenient for travel. Handheld personal electronic devices such as smartphones and digital voice recorders with relatively lower costs and higher performance have become widely available recently. Even though such devices are highly portable, directly implementing them for noise measurement may lead to erroneous results since such equipment was originally designed for voice recording. In this study, external microphones were connected to a digital voice recorder to conduct measurements and the input received was processed for noise visualization. In this way, a low cost, compact sound visualization system was designed and introduced to visualize two actual noise sources for verification with different characteristics: an enclosed loud speaker and a small air compressor. Reasonable accuracy of noise visualization for these two sources was shown over a relatively wide frequency range. This very affordable and compact sound visualization system can be used for many actual noise visualization applications in addition to educational purposes. PMID:29614038

  20. Development of High Precision Metal Micro-Electro-Mechanical-Systems Column for Portable Surface Acoustic Wave Gas Chromatograph

    NASA Astrophysics Data System (ADS)

    Iwaya, Takamitsu; Akao, Shingo; Sakamoto, Toshihiro; Tsuji, Toshihiro; Nakaso, Noritaka; Yamanaka, Kazushi

    2012-07-01

    In the field of environmental measurement and security, a portable gas chromatograph (GC) is required for the on-site analysis of multiple hazardous gases. Although the gas separation column has been downsized using micro-electro-mechanical-systems (MEMS) technology, an MEMS column made of silicon and glass still does not have sufficient robustness and a sufficiently low fabrication cost for a portable GC. In this study, we fabricated a robust and inexpensive high-precision metal MEMS column by combining diffusion-bonded etched stainless-steel plates with alignment evaluation using acoustic microscopy. The separation performance was evaluated using a desktop GC with a flame ionization detector and we achieved the high separation performance comparable to the best silicon MEMS column fabricated using a dynamic coating method. As an application, we fabricated a palm-size surface acoustic wave (SAW) GC combining this column with a ball SAW sensor and succeeded in separating and detecting a mixture of volatile organic compounds.

  1. Portable power source needs of the future Army -- Batteries and fuel cells

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jacobs, R.; Christopher, H.; Hamlen, R.

    This paper describes the US Army`s future needs for silent portable power in the area of batteries and fuel cells. These needs will continue to increase as a result of the introduction of newer types of equipment, the increasing digitization of the battlefield, and future integrated Soldier Systems. Current battery programs are aimed at improved, low-cost primary batteries, and rechargeable batteries with increased energy densities. The Army fuel cell program aimed at portable systems capable of the order of 150W is also described.

  2. Low cost mobile explosive/drug detection devices

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gozani, T.; Bendahan, J.

    1999-06-10

    Inspection technologies based on Thermal Neutron Analysis (TNA) and/or Fast Neutron Analysis (FNA) are the basis for relatively compact and low-cost, material-sensitive devices for a wide variety of inspection needs. The TNA allows the use of either isotropic neutron sources such as a {sup 252}Cf, or electronic neutron generators such as the d-T sealed neutron generator tubes. The latter could be used in a steady state mode or in slow (>{mu}s) pulsing mode, to separate the thermal neutron capture signatures following the pulse from the combination of the FNA plus TNA signatures during the pulse. Over the years, Ancore Corporationmore » has built and is continuing to develop a variety of inspection devices based on its TNA and FNA technologies: SPEDS--an explosive detection device for small parcels, portable electronics, briefcases and other similar carry-on items; MDS - a system for the detection or confirmation of buried mines; VEDS - a system for the detection of varied amounts of explosives and/or drugs concealed in passenger vehicles, pallets, lightly loaded trucks or containers, etc.; ACD - a device to clear alarms from a primary, non-specific explosive detection system for passenger luggage. The principle and performance of these devices will be shown and discussed.« less

  3. Automated Low-Cost Smartphone-Based Lateral Flow Saliva Test Reader for Drugs-of-Abuse Detection

    PubMed Central

    Carrio, Adrian; Sampedro, Carlos; Sanchez-Lopez, Jose Luis; Pimienta, Miguel; Campoy, Pascual

    2015-01-01

    Lateral flow assay tests are nowadays becoming powerful, low-cost diagnostic tools. Obtaining a result is usually subject to visual interpretation of colored areas on the test by a human operator, introducing subjectivity and the possibility of errors in the extraction of the results. While automated test readers providing a result-consistent solution are widely available, they usually lack portability. In this paper, we present a smartphone-based automated reader for drug-of-abuse lateral flow assay tests, consisting of an inexpensive light box and a smartphone device. Test images captured with the smartphone camera are processed in the device using computer vision and machine learning techniques to perform automatic extraction of the results. A deep validation of the system has been carried out showing the high accuracy of the system. The proposed approach, applicable to any line-based or color-based lateral flow test in the market, effectively reduces the manufacturing costs of the reader and makes it portable and massively available while providing accurate, reliable results. PMID:26610513

  4. Automated Low-Cost Smartphone-Based Lateral Flow Saliva Test Reader for Drugs-of-Abuse Detection.

    PubMed

    Carrio, Adrian; Sampedro, Carlos; Sanchez-Lopez, Jose Luis; Pimienta, Miguel; Campoy, Pascual

    2015-11-24

    Lateral flow assay tests are nowadays becoming powerful, low-cost diagnostic tools. Obtaining a result is usually subject to visual interpretation of colored areas on the test by a human operator, introducing subjectivity and the possibility of errors in the extraction of the results. While automated test readers providing a result-consistent solution are widely available, they usually lack portability. In this paper, we present a smartphone-based automated reader for drug-of-abuse lateral flow assay tests, consisting of an inexpensive light box and a smartphone device. Test images captured with the smartphone camera are processed in the device using computer vision and machine learning techniques to perform automatic extraction of the results. A deep validation of the system has been carried out showing the high accuracy of the system. The proposed approach, applicable to any line-based or color-based lateral flow test in the market, effectively reduces the manufacturing costs of the reader and makes it portable and massively available while providing accurate, reliable results.

  5. Low-cost failure sensor design and development for water pipeline distribution systems.

    PubMed

    Khan, K; Widdop, P D; Day, A J; Wood, A S; Mounce, S R; Machell, J

    2002-01-01

    This paper describes the design and development of a new sensor which is low cost to manufacture and install and is reliable in operation with sufficient accuracy, resolution and repeatability for use in newly developed systems for pipeline monitoring and leakage detection. To provide an appropriate signal, the concept of a "failure" sensor is introduced, in which the output is not necessarily proportional to the input, but is unmistakably affected when an unusual event occurs. The design of this failure sensor is based on the water opacity which can be indicative of an unusual event in a water distribution network. The laboratory work and field trials necessary to design and prove out this type of failure sensor are described here. It is concluded that a low-cost failure sensor of this type has good potential for use in a comprehensive water monitoring and management system based on Artificial Neural Networks (ANN).

  6. Development of a portable therapeutic and high intensity ultrasound system for military, medical, and research use

    PubMed Central

    Lewis, George K.; Olbricht, William L.

    2008-01-01

    We have developed a portable high power ultrasound system with a very low output impedance amplifier circuit (less than 0.3 Ω) that can transfer more than 90% of the energy from a battery supply to the ultrasound transducer. The system can deliver therapeutic acoustical energy waves at lower voltages than those in conventional ultrasound systems because energy losses owing to a mismatched impedance are eliminated. The system can produce acoustic power outputs over the therapeutic range (greater then 50 W) from a PZT-4, 1.54 MHz, and 0.75 in diameter piezoelectric ceramic. It is lightweight, portable, and powered by a rechargeable battery. The portable therapeutic ultrasound unit has the potential to replace “plug-in” medical systems and rf amplifiers used in research. The system is capable of field service on its internal battery, making it especially useful for military, ambulatory, and remote medical applications. PMID:19045903

  7. Low-cost compact ECG with graphic LCD and phonocardiogram system design.

    PubMed

    Kara, Sadik; Kemaloğlu, Semra; Kirbaş, Samil

    2006-06-01

    Till today, many different ECG devices are made in developing countries. In this study, low cost, small size, portable LCD screen ECG device, and phonocardiograph were designed. With designed system, heart sounds that take synchronously with ECG signal are heard as sensitive. Improved system consist three units; Unit 1, ECG circuit, filter and amplifier structure. Unit 2, heart sound acquisition circuit. Unit 3, microcontroller, graphic LCD and ECG signal sending unit to computer. Our system can be used easily in different departments of the hospital, health institution and clinics, village clinic and also in houses because of its small size structure and other benefits. In this way, it is possible that to see ECG signal and hear heart sounds as synchronously and sensitively. In conclusion, heart sounds are heard on the part of both doctor and patient because sounds are given to environment with a tiny speaker. Thus, the patient knows and hears heart sounds him/herself and is acquainted by doctor about healthy condition.

  8. Flexible and Low-Cost Measurements for Space Software Development- The Measurements Exploration Framework

    NASA Astrophysics Data System (ADS)

    Marculescu, Bogdan; Feldt, Robert; Torkar, Richard; Green, Lars-Goran; Liljegren, Thomas; Hult, Erika

    2011-08-01

    Verification and validation is an important part of software development and accounts for significant amounts of the costs associated with such a project. For developers of life or mission critical systems, such as software being developed for space applications, a balance must be reached between ensuring the quality of the system by extensive and rigorous testing and reducing costs and allowing the company to compete.Ensuring the quality of any system starts with a quality development process. To evaluate both the software development process and the product itself, measurements are needed. A balance must be then struck between ensuring the best possible quality of both process and product on the one hand, and reducing the cost of performing requirements on the other.A number of measurements have already been defined and are being used. For some of these, data collection can be automated as well, further lowering costs associated with implementing them. In practice, however, there may be situations where existing measurements are unsuitable for a variety of reasons.This paper describes a framework for creating low cost, flexible measurements in areas where initial information is scarce. The framework, called The Measurements Exploration Framework, is aimed in particular at the Space Software development industry and was developed is such an environment.

  9. Development of a low cost pupillometer-eyetracker and applications

    NASA Astrophysics Data System (ADS)

    Bianchetti, Arturo; Perez, Liliana I.; Comastri, Silvia A.

    2013-11-01

    The determination of ocular pupil diameter and gaze direction is important in various psychophysical and cognitive tests and can be accomplished using commercial, academic or open-source devices. In this work we develop a table-top pupillometer eyetracker termed Blick, the hardware costs 50 dollars and the software is open source (https://github.com/abianchetti/blick). The hardware is mounted in a portable holder and comprises an illumination system (two infrared LEDs generating 0.13 W/m2 at 22 cm) and a detection system (containing an USB camera, an infrared filter and a 16mm lens system) The software, programmed in C++ using OpenCV and cvblob libraries, processes eye images in real time and supplies plots and tables of pupil diameter and gaze direction and a video of the eye. As applications, capturing the right eye of six young emmetropes and after performing the pixel-mm and homographic calibrations (required to determine diameter in mm and gaze direction), we conduct three tests. The corresponding tasks are to detect mistakes in three series of four poker cards, to recognize letters F between distractors and to write a sentence via eye movements using Blick as eye tracker and the tool Dasher (MacKayśs Cambridge Group). We obtain that Blicḱs performance is satisfactory (errors being 0.05 mm in pupil diameter and 1 degree in gaze direction); that there are slight pupil dilations when subjects used to playing cards find mistakes and when some subjects find targets and, finally, that Blick can be employed as eyetracker to allow communication of disabled persons.

  10. Design and construction of portable survey meter

    NASA Astrophysics Data System (ADS)

    Singseeta, W.; Thong-aram, D.; Pencharee, S.

    2017-09-01

    This work was aimed to design and construction of portable survey meter for radiation dose measuring. The designed system consists of 4 main parts consisting of low voltage power supply, radiation detection, radiation measurement and data display part on android phone. The test results show that the ripple voltage of low voltage power supply is less than 1%, the maximum integral counts are found to be 104 counts per second and the maximum distance of wireless commination between the server and the client is about 10 meter. It was found that the developed system had small size and light weight for portable instrument.

  11. The Development of a Portable ECG Monitor Based on DSP

    NASA Astrophysics Data System (ADS)

    Nan, CHI Jian; Tao, YAN Yan; Meng Chen, LIU; Li, YANG

    With the advent of global information, researches of Smart Home system are in the ascendant, the ECG real-time detection, and wireless transmission of ECG become more useful. In order to achieve the purpose we developed a portable ECG monitor which achieves the purpose of cardiac disease remote monitoring, and will be used in the physical and psychological disease surveillance in smart home system, we developed this portable ECG Monitor, based on the analysis of existing ECG Monitor, using TMS320F2812 as the core controller, which complete the signal collection, storage, processing, waveform display and transmission.

  12. Solid Sampling with a Diode Laser for Portable Ambient Mass Spectrometry

    PubMed Central

    2017-01-01

    A hand-held diode laser is implemented for solid sampling in portable ambient mass spectrometry (MS). Specifically, a pseudocontinuous wave battery-powered surgical laser diode is employed for portable laser diode thermal desorption (LDTD) at 940 nm and compared with nanosecond pulsed laser ablation at 2940 nm. Postionization is achieved in both cases using atmospheric pressure photoionization (APPI). The laser ablation atmospheric pressure photoionization (LAAPPI) and LDTD-APPI mass spectra of sage leaves (Salvia officinalis) using a field-deployable quadrupole ion trap MS display many similar ion peaks, as do the mass spectra of membrane grown biofilms of Pseudomonas aeruginosa. These results indicate that LDTD-APPI method should be useful for in-field sampling of plant and microbial communities, for example, by portable ambient MS. The feasibility of many portable MS applications is facilitated by the availability of relatively low cost, portable, battery-powered diode lasers. LDTD could also be coupled with plasma- or electrospray-based ionization for the analysis of a variety of solid samples. PMID:28632988

  13. Development of a 500-Watt portable generator

    NASA Astrophysics Data System (ADS)

    Knochenhauer, Robert John

    In many commercial and recreational environments where power is unavailable, there is a need for lightweight, efficient, reasonably priced and quiet power sources that can recharge batteries for various portable devices. The current benchmark device is the Honda EU1000i, a 1000-Watt (peak) generator that weighs only 29 pounds (dry) and has a respectable noise level of 59 dB (at 7 meters) under peak power loading. The intent of this thesis study is to focus on the thermal management of a novel generator design that develops peak power of 500-Watts, weighs in at less than 20 pounds (dry) and has a reasonably low noise level at peak power loading. Through the course of this assessment, two key lessons are learned: • Liquid cooling at this scale is possible, but not practical • Renewable power sources (wind turbines and/or solar panels) are viable alternatives when used in environments that offer suitable conditions.

  14. AIRQino, a low-cost air quality mobile platform

    NASA Astrophysics Data System (ADS)

    Zaldei, Alessandro; Vagnoli, Carolina; Di Lonardo, Sara; Gioli, Beniamino; Gualtieri, Giovanni; Toscano, Piero; Martelli, Francesca; Matese, Alessandro

    2015-04-01

    Recent air quality regulations (Directive 2008/50/EC) enforce the transition from point-based monitoring networks to new tools that must be capable of mapping and forecasting air quality on the totality of land area, and therefore the totality of citizens. This implies new technologies such as models and additional indicative measurements, are needed in addition to accurate fixed air quality monitoring stations, that until now have been taken as reference by local administrators for the enforcement of various mitigation strategies. However, due to their sporadic spatial distribution, they cannot describe the highly resolved spatial pollutant variations within cities. Integrating additional indicative measurements may provide adequate information on the spatial distribution of the ambient air quality, also allowing for a reduction of the required minimum number of fixed sampling points, whose high cost and complex maintenance still remain a crucial concern for local administrators. New low-cost and small size sensors are becoming available, that could be employed in air quality monitoring including mobile applications. However, accurate assessment of their accuracy and performance both in controlled and real monitoring conditions is crucially needed. Quantifying sensor response is a significant challenge due to the sensitivity to ambient temperature and humidity and the cross-sensitivity to others pollutant species. This study reports the development of an Arduino compatible electronic board (AIRQino) which integrates a series of low-cost metal oxide and NDIR sensors for air quality monitoring, with sensors to measure air temperature, relative humidity, noise, solar radiation and vertical acceleration. A comparative assessment was made for CO2, CO, NO2, CH4, O3, VOCs concentrations, temperature and relative humidity. A controlled climatic chamber study (-80°C / +80°C) was performed to verify temperature and humidity interference using reference gas cylinders and

  15. Advances in developing rapid, reliable and portable detection systems for alcohol.

    PubMed

    Thungon, Phurpa Dema; Kakoti, Ankana; Ngashangva, Lightson; Goswami, Pranab

    2017-11-15

    Development of portable, reliable, sensitive, simple, and inexpensive detection system for alcohol has been an instinctive demand not only in traditional brewing, pharmaceutical, food and clinical industries but also in rapidly growing alcohol based fuel industries. Highly sensitive, selective, and reliable alcohol detections are currently amenable typically through the sophisticated instrument based analyses confined mostly to the state-of-art analytical laboratory facilities. With the growing demand of rapid and reliable alcohol detection systems, an all-round attempt has been made over the past decade encompassing various disciplines from basic and engineering sciences. Of late, the research for developing small-scale portable alcohol detection system has been accelerated with the advent of emerging miniaturization techniques, advanced materials and sensing platforms such as lab-on-chip, lab-on-CD, lab-on-paper etc. With these new inter-disciplinary approaches along with the support from the parallel knowledge growth on rapid detection systems being pursued for various targets, the progress on translating the proof-of-concepts to commercially viable and environment friendly portable alcohol detection systems is gaining pace. Here, we summarize the progress made over the years on the alcohol detection systems, with a focus on recent advancement towards developing portable, simple and efficient alcohol sensors. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. Low-cost/high-efficiency lasers for medical applications in the 14XX-nm regime

    NASA Astrophysics Data System (ADS)

    Callahan, J. J.; McIntyre, E.; Rafferty, C.; Yanushefski, L.; Bean, D. M.

    2011-03-01

    Laser therapy is becoming an increasingly popular method of treating numerous dermatological conditions. The widespread use of these devices is often limited by the cost and size. Low cost, portable lasers would expand the laser market further into homes, general practitioners, dermatologists, plastic surgeons, and 3rd world countries. There are numerous light devices currently on the market for hair removal and growth, acne reduction, and wrinkles. These devices are varied, from LEDs to intense pulsed light (IPL) to lasers. One particular disease is leishmaniasis, caused by a parasite carried by sand flies, most often occurring in third world countries. While there are drug therapies available, they sometimes require hospitalization for several days and are very expensive. An RF device has been FDA approved for treatment of leishmaniasis, but costs about $20,000 which is too expensive for widespread use. Since the method is heating the lesion, the same affect could be achieved using an infrared laser. Diode lasers have the capability to be produced in mass quantity for low costs, as shown by the ubiquity of diode lasers in the telecom industry and household appliances. Unfortunately, many diode lasers suffer from poor efficiency, particularly in wavelengths for dermatology. Advances are being made to improve wall plug efficiency of lasers to reduce waste heat and increase output power. In this paper, those efforts being made to develop manufacturing partners to lower the cost while increasing the production volume of long wavelength lasers will be discussed along with performance data and clinical results.

  17. Performance of a Low-Cost, Low-Concentration Photovoltaic Module

    NASA Astrophysics Data System (ADS)

    Shell, Kara A.; Brown, Scott A.; Schuetz, Mark A.; Davis, Bob J.; French, Roger H.

    2011-12-01

    In order to significantly reduce the cost of solar power, Replex Plastics has developed a low-cost, low-concentration PV module incorporating acrylic mirror reflectors. The reflectors are compound parabolic concentrators designed for use with low-accuracy single axis trackers. The prototypes use crystalline silicon photovoltaic cells and achieved 7.1x concentration over a receiver without reflectors. The 1×1.6 m module used 1/10th the silicon of a standard module and produced a max power of 140 W.

  18. Characteristics and applications of small, portable gaseous air pollution monitors.

    PubMed

    McKercher, Grant R; Salmond, Jennifer A; Vanos, Jennifer K

    2017-04-01

    Traditional approaches for measuring air quality based on fixed measurements are inadequate for personal exposure monitoring. To combat this issue, the use of small, portable gas-sensing air pollution monitoring technologies is increasing, with researchers and individuals employing portable and mobile methods to obtain more spatially and temporally representative air pollution data. However, many commercially available options are built for various applications and based on different technologies, assumptions, and limitations. A review of the monitor characteristics of small, gaseous monitors is missing from current scientific literature. A state-of-the-art review of small, portable monitors that measure ambient gaseous outdoor pollutants was developed to address broad trends during the last 5-10 years, and to help future experimenters interested in studying gaseous air pollutants choose monitors appropriate for their application and sampling needs. Trends in small, portable gaseous air pollution monitor uses and technologies were first identified and discussed in a review of literature. Next, searches of online databases were performed for articles containing specific information related to performance, characteristics, and use of such monitors that measure one or more of three criteria gaseous air pollutants: ozone, nitrogen dioxide, and carbon monoxide. All data were summarized into reference tables for comparison between applications, physical features, sensing capabilities, and costs of the devices. Recent portable monitoring trends are strongly related to associated applications and audiences. Fundamental research requires monitors with the best individual performance, and thus the highest cost technology. Monitor networking favors real-time capabilities and moderate cost for greater reproduction. Citizen science and crowdsourcing applications allow for lower-cost components; however important strengths and limitations for each application must be addressed

  19. Portable Biomarker Detection with Magnetic Nanotags

    PubMed Central

    Hall, Drew A.; Wang, Shan X.; Murmann, Boris; Gaster, Richard S.

    2012-01-01

    This paper presents a hand-held, portable biosensor platform for quantitative biomarker measurement. By combining magnetic nanoparticle (MNP) tags with giant magnetoresistive (GMR) spin-valve sensors, the hand-held platform achieves highly sensitive (picomolar) and specific biomarker detection in less than 20 minutes. The rapid analysis and potential low cost make this technology ideal for point-of-care (POC) diagnostics. Furthermore, this platform is able to detect multiple biomarkers simultaneously in a single assay, creating a promising diagnostic tool for a vast number of applications. PMID:22495252

  20. Development of a compact portable driver for a pneumatic ventricular assist device.

    PubMed

    Nishinaka, Tomohiro; Taenaka, Yoshiyuki; Tatsumi, Eisuke; Ohnishi, Hiroyuki; Homma, Akihiko; Shioya, Kyoko; Mizuno, Toshihide; Tsukiya, Tomonori; Mushika, Sadahiko; Hashiguchi, Yasuhiro; Suzuki, Akira; Kitamura, Soichiro

    2007-01-01

    The Toyobo-National Cardiovascular Center pneumatic ventricular assist device (Toyobo-NCVC VAD) is widely used in Japan; however, the current pneumatic drivers have some drawbacks, including their large size, heavy weight, and high power consumption. These issues cause difficulty with mobility and contribute to an unsatisfactory quality of life for patients. Because it is urgently necessary to improve patients' safety and quality of life, we have developed a compact, low-noise, portable VAD driver by utilizing an electrohydraulic actuator consisting of a brushless DC motor and a regenerative pump. This unit can be actuated for as long as 2 h with two rechargeable lightweight batteries as well as with external AC power. It is compact in size (33 x 25 x 43 cm) and light in weight (13 kg), and the unit is carried on a mobile wheeled cart. In vitro testing with a Toyobo-NCVC VAD demonstrated a sufficient pumping capacity of up to 8 l/min. We conclude that this newly-developed compact portable driver can provide a better quality of life and improved safety for patients using protracted pneumatic VAD support.

  1. High resolution, low cost solar cell contact development

    NASA Technical Reports Server (NTRS)

    Mardesich, N.

    1979-01-01

    The experimental work demonstrating the feasibility of the MIDFILM process as a low cost means of applying solar cell collector metallization as reported. Cell efficiencies of above 14% (AMl, 28 C) were achieved with fritted silver metallization. Environmental tests suggest that the metallization is slightly humidity sensitive and degradation is observed on cells with high series resistance. The major yield loss in the fabrication of cells was due to discontinuous grid lines, resulting in high series resitance. Standard lead-tin solder plated interconnections do not appear compatible with the MIDFILM contact. Copper, nickel and molybdemun base powder were investigated as low cost metallization systems. The copper based powder degraded the cell response. The nickel and molybdenum base powders oxidized when sintered in the oxidizing atmosphere necessary to ash the photoresin.

  2. A review on the applications of portable near-infrared spectrometers in the agro-food industry.

    PubMed

    dos Santos, Cláudia A Teixeira; Lopo, Miguel; Páscoa, Ricardo N M J; Lopes, João A

    2013-11-01

    Industry has created the need for a cost-effective and nondestructive quality-control analysis system. This requirement has increased interest in near-infrared (NIR) spectroscopy, leading to the development and marketing of handheld devices that enable new applications that can be implemented in situ. Portable NIR spectrometers are powerful instruments offering several advantages for nondestructive, online, or in situ analysis: small size, low cost, robustness, simplicity of analysis, sample user interface, portability, and ergonomic design. Several studies of on-site NIR applications are presented: characterization of internal and external parameters of fruits and vegetables; conservation state and fat content of meat and fish; distinguishing among and quality evaluation of beverages and dairy products; protein content of cereals; evaluation of grape ripeness in vineyards; and soil analysis. Chemometrics is an essential part of NIR spectroscopy manipulation because wavelength-dependent scattering effects, instrumental noise, ambient effects, and other sources of variability may complicate the spectra. As a consequence, it is difficult to assign specific absorption bands to specific functional groups. To achieve useful and meaningful results, multivariate statistical techniques (essentially involving regression techniques coupled with spectral preprocessing) are therefore required to extract the information hidden in the spectra. This work reviews the evolution of the use of portable near-infrared spectrometers in the agro-food industry.

  3. Possibility of material cost reduction toward development of low-cost second-generation superconducting wires

    NASA Astrophysics Data System (ADS)

    Ichinose, Ataru; Horii, Shigeru; Doi, Toshiya

    2017-10-01

    Two approaches to reducing the material cost of second-generation superconducting wires are proposed in this paper: (1) instead of the electrical stabilizing layers of silver and copper presently used on the superconducting layer, a Nb-doped SrTiO3 conductive buffer layer and cube-textured Cu are proposed as an advanced architecture, and (2) the use of an electromagnetic (EM) steel tape as a metal substrate of coated conductors in a conventional architecture. In structures fabricated without using electrical stabilizing layers on the superconducting layer, the critical current density achieved at 77 K in a self-field was approximately 2.6 MA/cm2. On the other hand, in the case of using EM steel tapes, although the critical current density was far from practical at the current stage, the biaxial alignment of YBa2Cu3O y (YBCO) and buffer layers was realized without oxidation on the metal surface. In this study, the possibility of material cost reduction has been strongly indicated toward the development of low-cost second-generation superconducting wires in the near future.

  4. Hand-portable liquid chromatographic instrumentation.

    PubMed

    Sharma, Sonika; Tolley, Luke T; Tolley, H Dennis; Plistil, Alex; Stearns, Stanley D; Lee, Milton L

    2015-11-20

    Over the last four decades, liquid chromatography (LC) has experienced an evolution to smaller columns and particles, new stationary phases and low flow rate instrumentation. However, the development of person-portable LC has not followed, mainly due to difficulties encountered in miniaturizing pumps and detectors, and in reducing solvent consumption. The recent introduction of small, non-splitting pumping systems and UV-absorption detectors for use with capillary columns has finally provided miniaturized instrumentation suitable for high-performance hand-portable LC. Fully integrated microfabricated LC still remains a significant challenge. Ion chromatography (IC) has been successfully miniaturized and applied for field analysis; however, applications are mostly limited to inorganic and small organic ions. This review covers advancements that make possible more rapid expansion of portable forms of LC and IC. Copyright © 2015 Elsevier B.V. All rights reserved.

  5. Development of OCR system for portable passport and visa reader

    NASA Astrophysics Data System (ADS)

    Visilter, Yury V.; Zheltov, Sergey Y.; Lukin, Anton A.

    1999-01-01

    The modern passport and visa documents include special machine-readable zones satisfied the ICAO standards. This allows to develop the special passport and visa automatic readers. However, there are some special problems in such OCR systems: low resolution of character images captured by CCD-camera (down to 150 dpi), essential shifts and slopes (up to 10 degrees), rich paper texture under the character symbols, non-homogeneous illumination. This paper presents the structure and some special aspects of OCR system for portable passport and visa reader. In our approach the binarization procedure is performed after the segmentation step, and it is applied to the each character site separately. Character recognition procedure uses the structural information of machine-readable zone. Special algorithms are developed for machine-readable zone extraction and character segmentation.

  6. Recovery Act: Low Cost Integrated Substrate for OLED Lighting Development

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Benton, Scott; Bhandari, Abhinav

    2012-12-26

    PPG pursued the development of an integrated substrate, including the anode, external, and internal extraction layers. The objective of PPG's program was to achieve cost reductions by displacing the existing expensive borosilicate or double-side polished float glass substrates and developing alternative electrodes and scalable light extraction layer technologies through focused and short-term applied research. One of the key highlights of the project was proving the feasibility of using PPG's high transmission Solarphire® float glass as a substrate to consistently achieve organic lightemitting diode (OLED) devices with good performance and high yields. Under this program, four low-cost alternatives to the Indiummore » Tin Oxide (ITO) anode were investigated using pilot-scale magnetron sputtered vacuum deposition (MSVD) and chemical vapor deposition (CVD) technologies. The anodes were evaluated by fabricating small and large phosphorescent organic lightemitting diode (PHOLED) devices at Universal Display Corporation (UDC). The device performance and life-times comparable to commercially available ITO anodes were demonstrated. A cost-benefit analysis was performed to down-select two anodes for further low-cost process development. Additionally, PPG developed and evaluated a number of scalable and compatible internal and external extraction layer concepts such as scattering layers on the outside of the glass substrate or between the transparent anode and the glass interface. In one external extraction layer (EEL) approach, sol-gel sprayed pyrolytic coatings were deposited using lab scale equipment by hand or automated spraying of sol-gel solutions on hot glass, followed by optimizing of scattering with minimal absorption. In another EEL approach, PPG tested large-area glass texturing by scratching a glass surface with an abrasive roller and acid etching. Efficacy enhancements of 1.27x were demonstrated using white PHOLED devices for 2.0mm substrates which are at

  7. Arduino: a low-cost multipurpose lab equipment.

    PubMed

    D'Ausilio, Alessandro

    2012-06-01

    Typical experiments in psychological and neurophysiological settings often require the accurate control of multiple input and output signals. These signals are often generated or recorded via computer software and/or external dedicated hardware. Dedicated hardware is usually very expensive and requires additional software to control its behavior. In the present article, I present some accuracy tests on a low-cost and open-source I/O board (Arduino family) that may be useful in many lab environments. One of the strengths of Arduinos is the possibility they afford to load the experimental script on the board's memory and let it run without interfacing with computers or external software, thus granting complete independence, portability, and accuracy. Furthermore, a large community has arisen around the Arduino idea and offers many hardware add-ons and hundreds of free scripts for different projects. Accuracy tests show that Arduino boards may be an inexpensive tool for many psychological and neurophysiological labs.

  8. Development of concepts for low-cost energy storage assemblies for annual cycle energy system applications

    NASA Astrophysics Data System (ADS)

    Alexander, G. H.; Cooper, D. L.; Cummings, C. A.; Reiber, E. E.

    1981-10-01

    Low cost energy storage assemblies were developed. In the search for low overall cost assemblies, many diverse concepts and materials were postulated and briefly evaluated. Cost rankings, descriptions, and discussions of the concepts were presented from which ORNL selected the following three concepts for the Phase 2 development: (1) a site constructed tank with reinforced concrete walls formed with specialized modular blocks which eliminates most concrete form work and provides integral R-20 insulation designated ORNLFF; (2) a site constructed tank with earth supported walls that are formed from elements common to residential, in-ground swimming pools, designated SWPL; (3) and a site assembled tank used in underground utility vaults, designated UTLBX. Detailed designs of free standing versions of the three concepts are presented.

  9. Low cost MATLAB-based pulse oximeter for deployment in research and development applications.

    PubMed

    Shokouhian, M; Morling, R C S; Kale, I

    2013-01-01

    Problems such as motion artifact and effects of ambient lights have forced developers to design different signal processing techniques and algorithms to increase the reliability and accuracy of the conventional pulse oximeter device. To evaluate the robustness of these techniques, they are applied either to recorded data or are implemented on chip to be applied to real-time data. Recorded data is the most common method of evaluating however it is not as reliable as real-time measurements. On the other hand, hardware implementation can be both expensive and time consuming. This paper presents a low cost MATLAB-based pulse oximeter that can be used for rapid evaluation of newly developed signal processing techniques and algorithms. Flexibility to apply different signal processing techniques, providing both processed and unprocessed data along with low implementation cost are the important features of this design which makes it ideal for research and development purposes, as well as commercial, hospital and healthcare application.

  10. Cost Modeling for low-cost planetary missions

    NASA Technical Reports Server (NTRS)

    Kwan, Eric; Habib-Agahi, Hamid; Rosenberg, Leigh

    2005-01-01

    This presentation will provide an overview of the JPL parametric cost models used to estimate flight science spacecrafts and instruments. This material will emphasize the cost model approaches to estimate low-cost flight hardware, sensors, and instrumentation, and to perform cost-risk assessments. This presentation will also discuss JPL approaches to perform cost modeling and the methodologies and analyses used to capture low-cost vs. key cost drivers.

  11. Development of a Low Cost High Frequency Pulse Tube Cryocooler

    NASA Astrophysics Data System (ADS)

    Wang, C.; Caughley, A. J.; Haywood, D. J.

    2008-03-01

    In cooperation with Industrial Research Ltd (IRL), Cryomech, Inc. is developing a low cost high frequency pulse tube cryocooler. The valveless compressor, developed at IRL, employs two S.S. diaphragms and a novel kinematics driven mechanism. The pulse tube cold head has co-axial configuration. It is separated from the compressor with a SS flexible line of 1 meter long. The test results demonstrate a very small orientation effect of the cold head (<3 K at any orientation). This pulse tube cryocooler provides flexibility for user's integration. It can provide 108W at 77K with an electric input power of 3.7 kW in the primary test.

  12. Low cost carbon fiber technology development for carbon fiber composite applications : phase 1.

    DOT National Transportation Integrated Search

    2008-01-01

    The main goals of this research program at UTSI were: 1) to produce low cost carbon fibers and 2) to develop specific carbonbased : material technologies to meet current and future high performance fiber-reinforced composite needs of FTA and other : ...

  13. Design and development of nEMoS, an all-in-one, low-cost, web-connected and 3D-printed device for environmental analysis.

    PubMed

    Salamone, Francesco; Belussi, Lorenzo; Danza, Ludovico; Ghellere, Matteo; Meroni, Italo

    2015-06-04

    The Indoor Environmental Quality (IEQ) refers to the quality of the environment in relation to the health and well-being of the occupants. It is a holistic concept, which considers several categories, each related to a specific environmental parameter. This article describes a low-cost and open-source hardware architecture able to detect the indoor variables necessary for the IEQ calculation as an alternative to the traditional hardware used for this purpose. The system consists of some sensors and an Arduino board. One of the key strengths of Arduino is the possibility it affords of loading the script into the board's memory and letting it run without interfacing with computers, thus granting complete independence, portability and accuracy. Recent works have demonstrated that the cost of scientific equipment can be reduced by applying open-source principles to their design using a combination of the Arduino platform and a 3D printer. The evolution of the 3D printer has provided a new means of open design capable of accelerating self-directed development. The proposed nano Environmental Monitoring System (nEMoS) instrument is shown to have good reliability and it provides the foundation for a more critical approach to the use of professional sensors as well as for conceiving new scenarios and potential applications.

  14. Low cost method for manufacturing a data acquisition system with USB connectivity

    NASA Astrophysics Data System (ADS)

    Niculescu, V.; Dobre, R. A.; Popovici, E.

    2016-06-01

    In the process of designing and manufacturing an electronic system the digital oscilloscope plays an essential role but it also represents one of the most expensive equipment present on the typical workbench. In order to make electronic design more accessible to students and hobbyists, an affordable data acquisition system was imagined. The paper extensively presents the development and testing of a low cost, medium speed, data acquisition system which can be used in a wide range of electronic measurement and debugging applications, assuring also great portability due to the small physical dimensions. Each hardware functional block and is thoroughly described, highlighting the challenges that occurred as well as the solutions to overcome them. The entire system was successfully manufactured using high quality components to assure increased reliability, and high frequency PCB materials and techniques were preferred. The measured values determined based on test signals were compared to the ones obtained using a digital oscilloscope available on the market and differences less than 1% were observed.

  15. Development and Evaluation of A Novel and Cost-Effective Approach for Low-Cost NO₂ Sensor Drift Correction.

    PubMed

    Sun, Li; Westerdahl, Dane; Ning, Zhi

    2017-08-19

    Emerging low-cost gas sensor technologies have received increasing attention in recent years for air quality measurements due to their small size and convenient deployment. However, in the diverse applications these sensors face many technological challenges, including sensor drift over long-term deployment that cannot be easily addressed using mathematical correction algorithms or machine learning methods. This study aims to develop a novel approach to auto-correct the drift of commonly used electrochemical nitrogen dioxide (NO₂) sensor with comprehensive evaluation of its application. The impact of environmental factors on the NO₂ electrochemical sensor in low-ppb concentration level measurement was evaluated in laboratory and the temperature and relative humidity correction algorithm was evaluated. An automated zeroing protocol was developed and assessed using a chemical absorbent to remove NO₂ as a means to perform zero correction in varying ambient conditions. The sensor system was operated in three different environments in which data were compared to a reference NO₂ analyzer. The results showed that the zero-calibration protocol effectively corrected the observed drift of the sensor output. This technique offers the ability to enhance the performance of low-cost sensor based systems and these findings suggest extension of the approach to improve data quality from sensors measuring other gaseous pollutants in urban air.

  16. NATIONAL STORMWATER CALCULATOR: LOW IMPACT DEVELOPMENT STORMWATER CONTROL COST ESTIMATION PROGRAMMING & FUTURE ENHANCEMENTS

    EPA Science Inventory

    National Stormwater Calculator: Low Impact Development Stormwater Control Cost Estimation Programming & Future EnhancementsJason Berner1; Michael Tryby1; Scott Struck2, Dan Pankani2, Marion Deerhake3, Michelle Simon11. USEPA2. GeoSyntec, Inc.3. RTI, Inc.The National Stormwater Ca...

  17. Fabrication and performance analysis of a low cost parabolic type solar cooker

    NASA Astrophysics Data System (ADS)

    Akter, Farhana Nasrin; Islam, Muhammed Kamrul; Begum, Nurun Nahar

    2017-06-01

    Developing countries depend mostly on natural fuel sources such as wood fuel, fossil fuel (kerosene and liquid petroleum gas) etc. for cooking purpose. However, these are expensive and also lead to the threads like deforestation as well as environmental degradation. An alternative renewable energy source like solar energy can contribute a solution towards the adverse crisis of fuel consumption along with environmental pollution of developing countries. Therefore, this study aims to design and fabricate a cost effective solar cooker for domestic purposes as well as performance analysis in order to evaluate its effectiveness. The cooker has been made of cardboard, tin, aluminum foil (polished and non-polished) and glass. Simple construction with reflectors surrounded by tin was fabricated with 1000ml load of water in the cooker hanging by a stand and observed that the best comparative performance in areas with longest durations of clear sky greatest direct ray falling on the collector cookers under moderate cloudy conditions. By applying better techniques for construction of solar cooker with low maintenance through testing and graphing the result, increasing of temperature with minimum cost for cooking purpose was outcome with portable cooker. In this analysis, analytical and experimental values varied due to fickle weather, however, maximum temperature variation was found 36 degree Celsius with efficiency 8.8% in the cooker made of aluminum foil (non-polished).

  18. Low cost fabrication development for oxide dispersion strengthened alloy vanes

    NASA Technical Reports Server (NTRS)

    Perkins, R. J.; Bailey, P. G.

    1978-01-01

    Viable processes were developed for secondary working of oxide dispersion strengthened (ODS) alloys to near-net shapes (NNS) for aircraft turbine vanes. These processes were shown capable of producing required microstructure and properties for vane applications. Material cost savings of 40 to 50% are projected for the NNS process over the current procedures which involve machining from rectangular bar. Additional machining cost savings are projected. Of three secondary working processes evaluated, directional forging and plate bending were determined to be viable NNS processes for ODS vanes. Directional forging was deemed most applicable to high pressure turbine (HPT) vanes with their large thickness variations while plate bending was determined to be most cost effective for low pressure turbine (LPT) vanes because of their limited thickness variations. Since the F101 LPT vane was selected for study in this program, development of plate bending was carried through to establishment of a preliminary process. Preparation of ODS alloy plate for bending was found to be a straight forward process using currently available bar stock, providing that the capability for reheating between roll passes is available. Advanced ODS-NiCrAl and ODS-FeCrAl alloys were utilized on this program. Workability of all alloys was adequate for directional forging and plate bending, but only the ODS-FeCrAl had adequate workability for shaped preform extrustion.

  19. Development and Testing of a Portable Vocal Accumulator

    ERIC Educational Resources Information Center

    Cheyne, Harold A.; Hanson, Helen M.; Genereux, Ronald P.; Stevens, Kenneth N.; Hillman, Robert E.

    2003-01-01

    This research note describes the design and testing of a device for unobtrusive, long-term ambulatory monitoring of voice use, named the Portable Vocal Accumulator (PVA). The PVA contains a digital signal processor for analyzing input from a neck-placed miniature accelerometer. During its development, accelerometer recordings were obtained from 99…

  20. DEMONSTRATION OF LOW COST, LOW BURDEN EXPOSURE MONITORING STRATEGIES

    EPA Science Inventory

    This study is designed to develop and demonstrate relevant, low-cost, low-burden monitoring strategies that could be used in large longitudinal exposure/epidemiological studies, such as the National Children's Study. The focus of this study is on (1) recruiting and retaining p...

  1. Miniature PCR based portable bioaerosol monitor development.

    PubMed

    Agranovski, I E; Usachev, E V; Agranovski, E; Usacheva, O V

    2017-01-01

    A portable bioaerosol monitor is greatly demanded technology in many areas including air quality control, occupational exposure assessment and health risk evaluation, environmental studies and, especially, in defence and bio-terrorism applications. Our recent groundwork allowed us to formulate the concept of a portable bioaerosol monitor, which needs to be light, user friendly, reliable and capable of detecting airborne pathogens within 1-1·5 h on the spot. Conceptually, the event of a bioaerosol concentration burst is determined by triggers to commence the representative air sampling with sequential real-time polymerase chain reaction (PCR) confirmation of the targeted micro-organism present in the air. To minimize reagent consumption and idle running of the technology, an event of a bioaerosol burst is confirmed by three parameters: aerosol particle size, concentration and composition. Only particle sizes above 200 nm attract interest in the bioaerosol. Only an elevated aerosol concentration above the threshold (background aerosol concentration) is a signal to commence the analytical procedure. The combination of our previously developed personal bioaerosol sampler, aerosol particle counter based trigger and portable real-time PCR device formed the basis of the bioaerosol monitoring technology. The portable real-time PCR device was advanced to provide internally controlled detection, significantly reducing false-positive alarms. The technique is capable of detecting selected airborne micro-organisms on the spot within 30-80 min, depending on the genome organization of the particular strain. Due to recent outbreaks of infectious airborne diseases and the continuing threat of intentionally released bioaerosol attacks, investigations into the possibility of the early and reliable detection of pathogenic micro-organisms in the air is becoming increasingly important. The proposed technology consisting of a bioaerosol sampler, technology trigger and PCR device is

  2. Point-of-care, portable microfluidic blood analyzer system

    NASA Astrophysics Data System (ADS)

    Maleki, Teimour; Fricke, Todd; Quesenberry, J. T.; Todd, Paul W.; Leary, James F.

    2012-03-01

    Recent advances in MEMS technology have provided an opportunity to develop microfluidic devices with enormous potential for portable, point-of-care, low-cost medical diagnostic tools. Hand-held flow cytometers will soon be used in disease diagnosis and monitoring. Despite much interest in miniaturizing commercially available cytometers, they remain costly, bulky, and require expert operation. In this article, we report progress on the development of a battery-powered handheld blood analyzer that will quickly and automatically process a drop of whole human blood by real-time, on-chip magnetic separation of white blood cells (WBCs), fluorescence analysis of labeled WBC subsets, and counting a reproducible fraction of the red blood cells (RBCs) by light scattering. The whole blood (WB) analyzer is composed of a micro-mixer, a special branching/separation system, an optical detection system, and electronic readout circuitry. A droplet of un-processed blood is mixed with the reagents, i.e. magnetic beads and fluorescent stain in the micro-mixer. Valve-less sorting is achieved by magnetic deflection of magnetic microparticle-labeled WBC. LED excitation in combination with an avalanche photodiode (APD) detection system is used for counting fluorescent WBC subsets using several colors of immune-Qdots, while counting a reproducible fraction of red blood cells (RBC) is performed using a laser light scatting measurement with a photodiode. Optimized branching/channel width is achieved using Comsol Multi-Physics™ simulation. To accommodate full portability, all required power supplies (40v, +/-10V, and +3V) are provided via step-up voltage converters from one battery. A simple onboard lock-in amplifier is used to increase the sensitivity/resolution of the pulse counting circuitry.

  3. Appdaptivity: An Internet of Things Device-Decoupled System for Portable Applications in Changing Contexts

    PubMed Central

    Díaz, Manuel; Rubio, Bartolomé; Van den Abeele, Floris

    2018-01-01

    Currently, applications in the Internet of Things (IoT) are tightly coupled to the underlying physical devices. As a consequence, upon adding a device, device replacement or user’s relocation to a different physical space, application developers have to re-perform installation and configuration processes to reconfigure applications, which bears costs in time and knowledge of low-level details. In the emerging IoT field, this issue is even more challenging due to its current unpredictable growth in term of applications and connected devices. In addition, IoT applications can be personalised to each end user and can be present in different environments. As a result, IoT scenarios are very changeable, presenting a challenge for IoT applications. In this paper we present Appdaptivity, a system that enables the development of portable device-decoupled applications that can be adapted to changing contexts. Through Appdaptivity, application developers can intuitively create portable and personalised applications, disengaging from the underlying physical infrastructure. Results confirms a good scalability of the system in terms of connected users and components involved. PMID:29701698

  4. Appdaptivity: An Internet of Things Device-Decoupled System for Portable Applications in Changing Contexts.

    PubMed

    Martín, Cristian; Hoebeke, Jeroen; Rossey, Jen; Díaz, Manuel; Rubio, Bartolomé; Van den Abeele, Floris

    2018-04-26

    Currently, applications in the Internet of Things (IoT) are tightly coupled to the underlying physical devices. As a consequence, upon adding a device, device replacement or user’s relocation to a different physical space, application developers have to re-perform installation and configuration processes to reconfigure applications, which bears costs in time and knowledge of low-level details. In the emerging IoT field, this issue is even more challenging due to its current unpredictable growth in term of applications and connected devices. In addition, IoT applications can be personalised to each end user and can be present in different environments. As a result, IoT scenarios are very changeable, presenting a challenge for IoT applications. In this paper we present Appdaptivity, a system that enables the development of portable device-decoupled applications that can be adapted to changing contexts. Through Appdaptivity, application developers can intuitively create portable and personalised applications, disengaging from the underlying physical infrastructure. Results confirms a good scalability of the system in terms of connected users and components involved.

  5. Design criteria for portable timber bridge systems : static versus dynamic loads

    Treesearch

    John M. Franklin; S. E. Taylor; Paul A. Morgan; M. A. Ritter

    1999-01-01

    Design criteria are needed specifically for portable bridges to insure that they are safe and cost effective. This paper discusses different portable bridge categories and their general design criteria. Specific emphasis is given to quantifying the effects of dynamic live loads on portable bridge design. Results from static and dynamic load tests of two portable timber...

  6. A hand-powered, portable, low-cost centrifuge for diagnosing anemia in low-resource settings.

    PubMed

    Brown, Jocelyn; Theis, Lauren; Kerr, Lila; Zakhidova, Nazima; O'Connor, Kelly; Uthman, Margaret; Oden, Z Maria; Richards-Kortum, Rebecca

    2011-08-01

    This report describes the development of a hand-powered centrifuge to determine hematocrit values in low-resource settings. A hand-powered centrifuge was constructed by using a salad spinner. Hematocrit values were measured by using the hand-powered device, and results were compared with those of a benchtop centrifuge. The packed cell volume (PCV) measured with the hand-powered device correlated linearly with results obtained with a benchtop centrifuge (r = 0.986, P < 0.001). The PCVs measured with the hand-powered centrifuge were consistently 1.14 times higher than those measured with the benchtop system. The 14% increase in PCV measured with the hand-powered centrifuge is caused by increased plasma trapped in the cell column. The reader card was adjusted to compensate for trapped plasma. A hand-powered centrifuge and calibrated reader card can be constructed for U.S. $35 and can accurately determine hematocrit values. It is suitable for use in low-resource settings because it is mechanically-powered, inexpensive, and accurate.

  7. A Hand-Powered, Portable, Low-Cost Centrifuge for Diagnosing Anemia in Low-Resource Settings

    PubMed Central

    Brown, Jocelyn; Theis, Lauren; Kerr, Lila; Zakhidova, Nazima; O'Connor, Kelly; Uthman, Margaret; Oden, Z. Maria; Richards-Kortum, Rebecca

    2011-01-01

    This report describes the development of a hand-powered centrifuge to determine hematocrit values in low-resource settings. A hand-powered centrifuge was constructed by using a salad spinner. Hematocrit values were measured by using the hand-powered device, and results were compared with those of a benchtop centrifuge. The packed cell volume (PCV) measured with the hand-powered device correlated linearly with results obtained with a benchtop centrifuge (r = 0.986, P < 0.001). The PCVs measured with the hand-powered centrifuge were consistently 1.14 times higher than those measured with the benchtop system. The 14% increase in PCV measured with the hand-powered centrifuge is caused by increased plasma trapped in the cell column. The reader card was adjusted to compensate for trapped plasma. A hand-powered centrifuge and calibrated reader card can be constructed for U.S. $35 and can accurately determine hematocrit values. It is suitable for use in low-resource settings because it is mechanically-powered, inexpensive, and accurate. PMID:21813855

  8. Development of Low-Cost Method for Fabrication of Metal Neutron Guides

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Engelhaupt, Darell; Khaykovich, Boris; Romaine, Suzanne

    Neutron scattering is one of the most useful methods of studying the structure and dynamics of matter. US DOE neutron scattering research facilities at Oak Ridge National Laboratory are among the World’s most advanced, providing researchers with unmatched capabilities for probing the structure and properties of materials, including engineering and biological systems. This task is to develop a lower cost process to optimize and produce the required neutron guides capable of efficiently delivering neutron beams for tens of meters between neutron moderators and instruments. Therefore, our effort is to improve the performance and lower the production cost of neutron guides.more » Our approach aims at improving guide quality while controlling their rising costs by adopting a novel electroforming replication approach to their fabrication. These guides will be especially advantageous when used near the neutron source since the radiation resistance of nickel is superior to glass. Additionally, we are depositing low-stress nickel from an extremely low impurity solution completely free of stress-reducing agents, which nominally contain and impart sulfur, carbon and other elements that potentially activate in the neutron environment. This is achieved by using a pulsed periodically reversed current methodology. The best guides quote waviness of 0.1 mrad. It is reasonable to prepare just one mandrel of about 0.5 m long, for production of tens of guide segments, saving both the cost and supply time of guides to neutron facilities. We estimate that we can fabricate a single mandrel for the current cost of an individual one-meter guide, but from this, we can produce tens of meters of guide very inexpensively without mandrel refurbishment. While a multilayer coating will add to the overall cost, we expect this will be less than that of commercially available guides today. Therefore, we will produce higher quality guides, which are less susceptible to radiation damage, at the

  9. Development of Low-Cost Method for Fabrication of Metal Neutron Guides

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Engelhaupt, Darell; Khaykovich, Boris; Romaine, Suzanne

    2017-12-19

    Neutron scattering is one of the most useful methods of studying the structure and dynamics of matter. US DOE neutron scattering research facilities at Oak Ridge National Laboratory are among the World’s most advanced, providing researchers with unmatched capabilities for probing the structure and properties of materials, including engineering and biological systems. This task is to develop a lower cost process to optimize and produce the required neutron guides capable of efficiently delivering neutron beams for tens of meters between neutron moderators and instruments. Therefore, our effort is to improve the performance and lower the production cost of neutron guides.more » Our approach aims at improving guide quality while controlling their rising costs by adopting a novel electroforming replication approach to their fabrication. These guides will be especially advantageous when used near the neutron source since the radiation resistance of nickel is superior to glass. Additionally, we are depositing low-stress nickel from an extremely low impurity solution completely free of stress-reducing agents, which nominally contain and impart sulfur, carbon and other elements that potentially activate in the neutron environment. This is achieved by using a pulsed periodically reversed current methodology. The best guides quote waviness of 0.1 mrad. It is reasonable to prepare just one mandrel of about 0.5 m long, for production of tens of guide segments, saving both the cost and supply time of guides to neutron facilities. We estimate that we can fabricate a single mandrel for the current cost of an individual one-meter guide, but from this, we can produce tens of meters of guide very inexpensively without mandrel refurbishment. While a multilayer coating will add to the overall cost, we expect this will be less than that of commercially available guides today. Therefore, we will produce higher quality guides, which are less susceptible to radiation damage, at the

  10. Draw your assay: Fabrication of low-cost paper-based diagnostic and multi-well test zones by drawing on a paper.

    PubMed

    Oyola-Reynoso, Stephanie; Heim, Andrew P; Halbertsma-Black, Julian; Zhao, C; Tevis, Ian D; Çınar, Simge; Cademartiri, Rebecca; Liu, Xinyu; Bloch, Jean-Francis; Thuo, Martin M

    2015-11-01

    Interest in low-cost diagnostic devices has recently gained attention, in part due to the rising cost of healthcare and the need to serve populations in resource-limited settings. A major challenge in the development of such devices is the need for hydrophobic barriers to contain polar bio-fluid analytes. Key approaches in lowering the cost in diagnostics have centered on (i) development of low-cost fabrication techniques/processes, (ii) use of affordable materials, or, (iii) minimizing the need for high-tech tools. This communication describes a simple, low-cost, adaptable, and portable method for patterning paper and subsequent use of the patterned paper in diagnostic tests. Our approach generates hydrophobic regions using a ball-point pen filled with a hydrophobizing molecule suspended in a solvent carrier. An empty ball-point pen was filled with a solution of trichloro perfluoroalkyl silane in hexanes (or hexadecane), and the pen used to draw lines on Whatman® chromatography 1 paper. The drawn regions defined the test zones since the trichloro silane reacts with the paper to give a hydrophobic barrier. The formation of the hydrophobic barriers is reaction kinetic and diffusion-limited, ensuring well defined narrow barriers. We performed colorimetric glucose assays and enzyme-linked immuno-sorbent assay (ELISA) using the created test zones. To demonstrate the versatility of this approach, we fabricated multiple devices on a single piece of paper and demonstrated the reproducibility of assays on these devices. The overall cost of devices fabricated by drawing are relatively lower (

  11. From Sour Grapes to Low-Hanging Fruit: A Case Study Demonstrating a Practical Strategy for Natural Language Processing Portability.

    PubMed

    Johnson, Stephen B; Adekkanattu, Prakash; Campion, Thomas R; Flory, James; Pathak, Jyotishman; Patterson, Olga V; DuVall, Scott L; Major, Vincent; Aphinyanaphongs, Yindalon

    2018-01-01

    Natural Language Processing (NLP) holds potential for patient care and clinical research, but a gap exists between promise and reality. While some studies have demonstrated portability of NLP systems across multiple sites, challenges remain. Strategies to mitigate these challenges can strive for complex NLP problems using advanced methods (hard-to-reach fruit), or focus on simple NLP problems using practical methods (low-hanging fruit). This paper investigates a practical strategy for NLP portability using extraction of left ventricular ejection fraction (LVEF) as a use case. We used a tool developed at the Department of Veterans Affair (VA) to extract the LVEF values from free-text echocardiograms in the MIMIC-III database. The approach showed an accuracy of 98.4%, sensitivity of 99.4%, a positive predictive value of 98.7%, and F-score of 99.0%. This experience, in which a simple NLP solution proved highly portable with excellent performance, illustrates the point that simple NLP applications may be easier to disseminate and adapt, and in the short term may prove more useful, than complex applications.

  12. 30 CFR 77.900 - Low- and medium-voltage circuits serving portable or mobile three-phase alternating current...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Low- and medium-voltage circuits serving... Medium-Voltage Alternating Current Circuits § 77.900 Low- and medium-voltage circuits serving portable or mobile three-phase alternating current equipment; circuit breakers. Low- and medium-voltage circuits...

  13. 30 CFR 77.900 - Low- and medium-voltage circuits serving portable or mobile three-phase alternating current...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Low- and medium-voltage circuits serving... Medium-Voltage Alternating Current Circuits § 77.900 Low- and medium-voltage circuits serving portable or mobile three-phase alternating current equipment; circuit breakers. Low- and medium-voltage circuits...

  14. 30 CFR 77.900 - Low- and medium-voltage circuits serving portable or mobile three-phase alternating current...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Low- and medium-voltage circuits serving... Medium-Voltage Alternating Current Circuits § 77.900 Low- and medium-voltage circuits serving portable or mobile three-phase alternating current equipment; circuit breakers. Low- and medium-voltage circuits...

  15. Development of Low-Cost Instrumentation for Single Point Autofluorescence Lifetime Measurements.

    PubMed

    Lagarto, João; Hares, Jonathan D; Dunsby, Christopher; French, Paul M W

    2017-09-01

    Autofluorescence lifetime measurements, which can provide label-free readouts in biological tissues, contrasting e.g. different types and states of tissue matrix components and different cellular metabolites, may have significant clinical potential for diagnosis and to provide surgical guidance. However, the cost of the instrumentation typically used currently presents a barrier to wider implementation. We describe a low-cost single point time-resolved autofluorescence instrument, exploiting modulated laser diodes for excitation and FPGA-based circuitry for detection, together with a custom constant fraction discriminator. Its temporal accuracy is compared against a "gold-standard" instrument incorporating commercial TCSPC circuitry by resolving the fluorescence decays of reference fluorophores presenting single and double exponential decay profiles. To illustrate the potential to read out intrinsic contrast in tissue, we present preliminary measurements of autofluorescence lifetime measurements of biological tissues ex vivo. We believe that the lower cost of this instrument could enhance the potential of autofluorescence lifetime metrology for clinical deployment and commercial development.

  16. A systematic review of portable electronic technology for health education in resource-limited settings.

    PubMed

    McHenry, Megan S; Fischer, Lydia J; Chun, Yeona; Vreeman, Rachel C

    2017-08-01

    The objective of this study is to conduct a systematic review of the literature of how portable electronic technologies with offline functionality are perceived and used to provide health education in resource-limited settings. Three reviewers evaluated articles and performed a bibliography search to identify studies describing health education delivered by portable electronic device with offline functionality in low- or middle-income countries. Data extracted included: study population; study design and type of analysis; type of technology used; method of use; setting of technology use; impact on caregivers, patients, or overall health outcomes; and reported limitations. Searches yielded 5514 unique titles. Out of 75 critically reviewed full-text articles, 10 met inclusion criteria. Study locations included Botswana, Peru, Kenya, Thailand, Nigeria, India, Ghana, and Tanzania. Topics addressed included: development of healthcare worker training modules, clinical decision support tools, patient education tools, perceptions and usability of portable electronic technology, and comparisons of technologies and/or mobile applications. Studies primarily looked at the assessment of developed educational modules on trainee health knowledge, perceptions and usability of technology, and comparisons of technologies. Overall, studies reported positive results for portable electronic device-based health education, frequently reporting increased provider/patient knowledge, improved patient outcomes in both quality of care and management, increased provider comfort level with technology, and an environment characterized by increased levels of technology-based, informal learning situations. Negative assessments included high investment costs, lack of technical support, and fear of device theft. While the research is limited, portable electronic educational resources present promising avenues to increase access to effective health education in resource-limited settings, contingent

  17. Low Cost Cryocoolers for High Temperature Superconductor Communication Filters

    NASA Technical Reports Server (NTRS)

    Brown, Davina

    1998-01-01

    This final report describes the work performed by a consortium of Industry and Government to develop low cost cryocoolers. The specific application was for low cost commercial based high temperature superconductor communication filters. This program was initiated in January 1995 and resulted in the successful demonstration of an HTS filter dewar cooled by a low cost pulse tube cryocooler. Further development of this cryocooler technology is proceeding through various contracts underway and proposed at this time.

  18. Development of CMOS Active Pixel Image Sensors for Low Cost Commercial Applications

    NASA Technical Reports Server (NTRS)

    Fossum, E.; Gee, R.; Kemeny, S.; Kim, Q.; Mendis, S.; Nakamura, J.; Nixon, R.; Ortiz, M.; Pain, B.; Zhou, Z.; hide

    1994-01-01

    This paper describes ongoing research and development of CMOS active pixel image sensors for low cost commercial applications. A number of sensor designs have been fabricated and tested in both p-well and n-well technologies. Major elements in the development of the sensor include on-chip analog signal processing circuits for the reduction of fixed pattern noise, on-chip timing and control circuits and on-chip analog-to-digital conversion (ADC). Recent results and continuing efforts in these areas will be presented.

  19. Development of low-cost directionally-solidified turbine blades

    NASA Technical Reports Server (NTRS)

    Hoppin, G. S., III; Fujii, M.; Sink, L. W.

    1980-01-01

    A low-cost directionally solidified (DS) casting of turbine blades of high stress rupture is discussed. The process uses an exothermically heated mold; a newly designed solid blade was cast for the high-pressure turbine of the TFE731-3 turbofan engine. Ni-based alloys Mar-M 247 and Mar-M 200 + Hf were used. The solid DS blade replaced a conventionally cast IN100 component; a 40% cost saving is expected, with a 2.4% reduction in the takeoff specific fuel consumption. The DS Mar-M 247 blade has been selected for production in the TFE731-3B-100, and advanced version of the TFE731-3.

  20. Portable ultrasonography in mass casualty incidents: The CAVEAT examination.

    PubMed

    Stawicki, Stanislaw Peter; Howard, James M; Pryor, John P; Bahner, David P; Whitmill, Melissa L; Dean, Anthony J

    2010-11-18

    Ultrasonography used by practicing clinicians has been shown to be of utility in the evaluation of time-sensitive and critical illnesses in a range of environments, including pre-hospital triage, emergency department, and critical care settings. The increasing availability of light-weight, robust, user-friendly, and low-cost portable ultrasound equipment is particularly suited for use in the physically and temporally challenging environment of a multiple casualty incident (MCI). Currently established ultrasound applications used to identify potentially lethal thoracic or abdominal conditions offer a base upon which rapid, focused protocols using hand-carried emergency ultrasonography could be developed. Following a detailed review of the current use of portable ultrasonography in military and civilian MCI settings, we propose a protocol for sonographic evaluation of the chest, abdomen, vena cava, and extremities for acute triage. The protocol is two-tiered, based on the urgency and technical difficulty of the sonographic examination. In addition to utilization of well-established bedside abdominal and thoracic sonography applications, this protocol incorporates extremity assessment for long-bone fractures. Studies of the proposed protocol will need to be conducted to determine its utility in simulated and actual MCI settings.

  1. Low-weight, low-cost, low-cycle time, replicated glass mirrors

    NASA Astrophysics Data System (ADS)

    Egerman, Robert; De Smitt, Steven; Strafford, David

    2010-07-01

    ITT has patented and continues to develop processes to fabricate low-cost borosilicate mirrors that can be used for both ground and space-based optical telescopes. Borosilicate glass is a commodity and is the material of choice for today's flat-panel televisions and monitors. Supply and demand has kept its cost low compared to mirror substrate materials typically found in telescopes. The current technology development is on the path to having the ability to deliver imaging quality optics of up to 1m (scalable to 2m) in diameter in three weeks. For those applications that can accommodate the material properties of borosilicate glasses, this technology has the potential to revolutionize ground and space-based astronomy. ITT Corporation has demonstrated finishing a planar, 0.6m borosilicate, optic to <100 nm-rms. This paper will provide an historical overview of the development in this area with an emphasis on recent technology developments to fabricate a 0.6m parabolic mirror under NASA Earth Science Technology Office (ESTO) grant #NNX09AD61G.

  2. [Development of a medical equipment support information system based on PDF portable document].

    PubMed

    Cheng, Jiangbo; Wang, Weidong

    2010-07-01

    According to the organizational structure and management system of the hospital medical engineering support, integrate medical engineering support workflow to ensure the medical engineering data effectively, accurately and comprehensively collected and kept in electronic archives. Analyse workflow of the medical, equipment support work and record all work processes by the portable electronic document. Using XML middleware technology and SQL Server database, complete process management, data calculation, submission, storage and other functions. The practical application shows that the medical equipment support information system optimizes the existing work process, standardized and digital, automatic and efficient orderly and controllable. The medical equipment support information system based on portable electronic document can effectively optimize and improve hospital medical engineering support work, improve performance, reduce costs, and provide full and accurate digital data

  3. Development of a Miniaturized and Portable Methane Analyzer for Natural Gas Leak Walking Surveys

    NASA Astrophysics Data System (ADS)

    Huang, Y. W.; Leen, J. B.; Gupta, M.; Baer, D. S.

    2016-12-01

    Traditional natural gas leak walking surveys have been conducted with devices that are based on technologies such as flame ionization detector (FID), IR-based spectrometer and IR camera. The sensitivity is typically on the ppm level. The low sensitivity means the device cannot pick up leaks far from it, and more time is spent surveying the area before pinpointing the leak location. A miniaturized methane analyzer has been developed to significantly improve the sensitivity of the device used in walking surveys to detect natural gas leaks at greater distance. ABB/LGR's patented Off-Axis Integrated Cavity Output Spectroscopy (OA-ICOS) is utilized to offer rugged and highly sensitive methane detection in a portable package. The miniaturized package weighs 13.5 lb, with a 4-hour rechargeable battery inside. The precision of the analyzer for methane is 2 ppb at 1 second. The analyzer operates at 10 Hz and its flow response time is 3 seconds for measurements through a 1-meter long sampling wand to registering on the data stream. The data can be viewed in real-time on a tablet or a smartphone. The compact and simplified package of the methane analyzer allows for more efficient walking surveys. It also allows for other applications that require low-power, low-weight and a portable package. We present data from walking surveys to demonstrate its ability to detect methane leaks.

  4. Portable retinal imaging for eye disease screening using a consumer-grade digital camera

    NASA Astrophysics Data System (ADS)

    Barriga, Simon; Larichev, Andrey; Zamora, Gilberto; Soliz, Peter

    2012-03-01

    The development of affordable means to image the retina is an important step toward the implementation of eye disease screening programs. In this paper we present the i-RxCam, a low-cost, hand-held, retinal camera for widespread applications such as tele-retinal screening for eye diseases like diabetic retinopathy (DR), glaucoma, and age-related ocular diseases. Existing portable retinal imagers do not meet the requirements of a low-cost camera with sufficient technical capabilities (field of view, image quality, portability, battery power, and ease-of-use) to be distributed widely to low volume clinics, such as the offices of single primary care physicians serving rural communities. The i-RxCam uses a Nikon D3100 digital camera body. The camera has a CMOS sensor with 14.8 million pixels. We use a 50mm focal lens that gives a retinal field of view of 45 degrees. The internal autofocus can compensate for about 2D (diopters) of focusing error. The light source is an LED produced by Philips with a linear emitting area that is transformed using a light pipe to the optimal shape at the eye pupil, an annulus. To eliminate corneal reflex we use a polarization technique in which the light passes through a nano-wire polarizer plate. This is a novel type of polarizer featuring high polarization separation (contrast ratio of more than 1000) and very large acceptance angle (>45 degrees). The i-RxCam approach will yield a significantly more economical retinal imaging device that would allow mass screening of the at-risk population.

  5. Power sources for portable electronics and hybrid cars: lithium batteries and fuel cells.

    PubMed

    Scrosati, Bruno

    2005-01-01

    The activities in progress in our laboratory for the development of batteries and fuel cells for portable electronics and hybrid car applications are reviewed and discussed. In the case of lithium batteries, the research has been mainly focused on the characterization of new electrode and electrolyte materials. Results related to disordered carbon anodes and improved, solvent-free, as well as gel-type, polymer electrolytes are particularly stressed. It is shown that the use of proper gel electrolytes, in combination with suitable electrode couples, allows the development of new types of safe, reliable, and low-cost lithium ion batteries which appear to be very promising power sources for hybrid vehicles. Some of the technologies proven to be successful in the lithium battery area are readapted for use in fuel cells. In particular, this approach has been followed for the preparation of low-cost and stable protonic membranes to be proposed as an alternative to the expensive, perfluorosulfonic membranes presently used in polymer electrolyte membrane fuel cells (PEMFCs). Copyright 2005 The Japan Chemical Journal Forum and Wiley Periodicals, Inc

  6. Simulation Based Low-Cost Composite Process Development at the US Air Force Research Laboratory

    NASA Technical Reports Server (NTRS)

    Rice, Brian P.; Lee, C. William; Curliss, David B.

    2003-01-01

    Low-cost composite research in the US Air Force Research Laboratory, Materials and Manufacturing Directorate, Organic Matrix Composites Branch has focused on the theme of affordable performance. Practically, this means that we use a very broad view when considering the affordability of composites. Factors such as material costs, labor costs, recurring and nonrecurring manufacturing costs are balanced against performance to arrive at the relative affordability vs. performance measure of merit. The research efforts discussed here are two projects focused on affordable processing of composites. The first topic is the use of a neural network scheme to model cure reaction kinetics, then utilize the kinetics coupled with simple heat transport models to predict, in real-time, future exotherms and control them. The neural network scheme is demonstrated to be very robust and a much more efficient method that mechanistic cure modeling approach. This enables very practical low-cost processing of thick composite parts. The second project is liquid composite molding (LCM) process simulation. LCM processing of large 3D integrated composite parts has been demonstrated to be a very cost effective way to produce large integrated aerospace components specific examples of LCM processes are resin transfer molding (RTM), vacuum assisted resin transfer molding (VARTM), and other similar approaches. LCM process simulation is a critical part of developing an LCM process approach. Flow simulation enables the development of the most robust approach to introducing resin into complex preforms. Furthermore, LCM simulation can be used in conjunction with flow front sensors to control the LCM process in real-time to account for preform or resin variability.

  7. A Low-Cost and Portable Dual-Channel Fiber Optic Surface Plasmon Resonance System.

    PubMed

    Liu, Qiang; Liu, Yun; Chen, Shimeng; Wang, Fang; Peng, Wei

    2017-12-04

    A miniaturization and integration dual-channel fiber optic surface plasmon resonance (SPR) system was proposed and demonstrated in this paper. We used a yellow light-emitting diode (LED, peak wavelength 595 nm) and built-in web camera as a light source and detector, respectively. Except for the detection channel, one of the sensors was used as a reference channel to compensate nonspecific binding and physical absorption. We packaged the LED and surface plasmon resonance (SPR) sensors together, which are flexible enough to be applied to mobile devices as a compact and portable system. Experimental results show that the normalized intensity shift and refractive index (RI) of the sample have a good linear relationship in the RI range from 1.328 to 1.348. We used this sensor to monitor the reversible, specific interaction between lectin concanavalin A (Con A) and glycoprotein ribonuclease B (RNase B), which demonstrate its capabilities of specific identification and biochemical samples concentration detection. This sensor system has potential applications in various fields, such as medical diagnosis, public health, food safety, and environment monitoring.

  8. A portable fNIRS system with eight channels

    NASA Astrophysics Data System (ADS)

    Si, Juanning; Zhao, Ruirui; Zhang, Yujin; Zuo, Nianming; Zhang, Xin; Jiang, Tianzi

    2015-03-01

    Abundant study on the hemodynamic response of a brain have brought quite a few advances in technologies of measuring it. The most benefitted is the functional near infrared spectroscope (fNIRS). A variety of devices have been developed for different applications. Because portable fNIRS systems were more competent to measure responses either of special subjects or in natural environment, several kinds of portable fNIRS systems have been reported. However, they all required a computer for receiving data. The extra computer increases the cost of a fNIRS system. What's more noticeable is the space required to locate the computer even for a portable system. It will discount the portability of the fNIRS system. So we designed a self-contained eight channel fNIRS system, which does not demand a computer to receive data and display data in a monitor. Instead, the system is centered by an ARM core CPU, which takes charge in organizing data and saving data, and then displays data on a touch screen. The system has also been validated by experiments on phantoms and on subjects in tasks.

  9. Low-Cost High-Pressure Hydrogen Generator

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cropley, Cecelia C.; Norman, Timothy J.

    Electrolysis of water, particularly in conjunction with renewable energy sources, is potentially a cost-effective and environmentally friendly method of producing hydrogen at dispersed forecourt sites, such as automotive fueling stations. The primary feedstock for an electrolyzer is electricity, which could be produced by renewable sources such as wind or solar that do not produce carbon dioxide or other greenhouse gas emissions. However, state-of-the-art electrolyzer systems are not economically competitive for forecourt hydrogen production due to their high capital and operating costs, particularly the cost of the electricity used by the electrolyzer stack. In this project, Giner Electrochemical Systems, LLC (GES)more » developed a low cost, high efficiency proton-exchange membrane (PEM) electrolysis system for hydrogen production at moderate pressure (300 to 400 psig). The electrolyzer stack operates at differential pressure, with hydrogen produced at moderate pressure while oxygen is evolved at near-atmospheric pressure, reducing the cost of the water feed and oxygen handling subsystems. The project included basic research on catalysts and membranes to improve the efficiency of the electrolysis reaction as well as development of advanced materials and component fabrication methods to reduce the capital cost of the electrolyzer stack and system. The project culminated in delivery of a prototype electrolyzer module to the National Renewable Energy Laboratory for testing at the National Wind Technology Center. Electrolysis cell efficiency of 72% (based on the lower heating value of hydrogen) was demonstrated using an advanced high-strength membrane developed in this project. This membrane would enable the electrolyzer system to exceed the DOE 2012 efficiency target of 69%. GES significantly reduced the capital cost of a PEM electrolyzer stack through development of low cost components and fabrication methods, including a 60% reduction in stack parts count

  10. Development of a rapid low cost fluorescent biosensor for the detection of food contaminants.

    PubMed

    McGrath, Terry F; Andersson, Karl; Campbell, Katrina; Fodey, Terry L; Elliott, Christopher T

    2013-03-15

    A prototype fluorescent based biosensor has been developed for the antibody based detection of food related contaminants. Its performance was characterised and showed a typical antibody binding signal of 200-2000 mV, a short term noise of 9.1 mV, and baseline slope of -0.016 mV/s over 4h. Bulk signal detection repeatability (n=23) and reproducibility (n=3) were less than 2.4%CV. The biosensor detection unit was evaluated using two food related model systems proving its ability to monitor both binding using commercial products and inhibition through the development of an assay. This assay development potential was evaluated by observing the biosensor's performance whilst appraising several labelled antibody and glass slide configurations. The molecular interaction between biotin and an anti-biotin antibody was shown to be inhibited by 41% due to the presence of biotin in a sample. A food toxin (domoic acid) calibration curve was produced, with %CVs ranging from 2.7 to 7.8%, and a midpoint of approximately 17 ng/ml with further optimisation possible. The ultimate aim of this study was to demonstrate the working principles of this innovative biosensor as a potential portable tool with the opportunity of interchangeable assays. The biosensor design is applicable for the requirements of routine food contaminant analysis, with respect to performance, functionality and cost. Copyright © 2012 Elsevier B.V. All rights reserved.

  11. Development of Innovative Technology to Provide Low-Cost Surface Atmospheric Observations

    NASA Astrophysics Data System (ADS)

    Kucera, Paul; Steinson, Martin

    2016-04-01

    Accurate and reliable real-time monitoring and dissemination of observations of surface weather conditions is critical for a variety of societal applications. Applications that provide local and regional information about temperature, precipitation, moisture, and winds, for example, are important for agriculture, water resource monitoring, health, and monitoring of hazard weather conditions. In many regions in Africa (and other global locations), surface weather stations are sparsely located and/or of poor quality. Existing stations have often been sited incorrectly, not well-maintained, and have limited communications established at the site for real-time monitoring. The US National Weather Service (NWS) International Activities Office (IAO) in partnership with University Corporation for Atmospheric Research (UCAR)/National Center for Atmospheric Research (NCAR) and funded by the United States Agency for International Development (USAID) Office of Foreign Disaster Assistance (OFDA) has started an initiative to develop and deploy low-cost weather instrumentation in sparsely observed regions of the world. The goal is to provide observations for environmental monitoring, and early warning alert systems that can be deployed at weather services in developing countries. Instrumentation is being designed using innovative new technologies such as 3D printers, Raspberry Pi computing systems, and wireless communications. The initial effort is focused on designing a surface network using GIS-based tools, deploying an initial network in Zambia, and providing training to Zambia Meteorological Department (ZMD) staff. The presentation will provide an overview of the project concepts, design of the low cost instrumentation, and initial experiences deploying a surface network deployment in Zambia.

  12. Design and Development of nEMoS, an All-in-One, Low-Cost, Web-Connected and 3D-Printed Device for Environmental Analysis

    PubMed Central

    Salamone, Francesco; Belussi, Lorenzo; Danza, Ludovico; Ghellere, Matteo; Meroni, Italo

    2015-01-01

    The Indoor Environmental Quality (IEQ) refers to the quality of the environment in relation to the health and well-being of the occupants. It is a holistic concept, which considers several categories, each related to a specific environmental parameter. This article describes a low-cost and open-source hardware architecture able to detect the indoor variables necessary for the IEQ calculation as an alternative to the traditional hardware used for this purpose. The system consists of some sensors and an Arduino board. One of the key strengths of Arduino is the possibility it affords of loading the script into the board’s memory and letting it run without interfacing with computers, thus granting complete independence, portability and accuracy. Recent works have demonstrated that the cost of scientific equipment can be reduced by applying open-source principles to their design using a combination of the Arduino platform and a 3D printer. The evolution of the 3D printer has provided a new means of open design capable of accelerating self-directed development. The proposed nano Environmental Monitoring System (nEMoS) instrument is shown to have good reliability and it provides the foundation for a more critical approach to the use of professional sensors as well as for conceiving new scenarios and potential applications. PMID:26053749

  13. Feasibility of using low-cost portable particle monitors for measurement of fine and coarse particulate matter in urban ambient air.

    PubMed

    Han, Inkyu; Symanski, Elaine; Stock, Thomas H

    2017-03-01

    Exposure to ambient particulate matter (PM) is known as a significant risk factor for mortality and morbidity due to cardiorespiratory causes. Owing to increased interest in assessing personal and community exposures to PM, we evaluated the feasibility of employing a low-cost portable direct-reading instrument for measurement of ambient air PM exposure. A Dylos DC 1700 PM sensor was collocated with a Grimm 11-R in an urban residential area of Houston Texas. The 1-min averages of particle number concentrations for sizes between 0.5 and 2.5 µm (small size) and sizes larger than 2.5 µm (large size) from a DC 1700 were compared with the 1-min averages of PM 2.5 (aerodynamic size less than 2.5 µm) and coarse PM (aerodynamic size between 2.5 and 10 µm) concentrations from a Grimm 11-R. We used a linear regression equation to convert DC 1700 number concentrations to mass concentrations, utilizing measurements from the Grimm 11-R. The estimated average DC 1700 PM 2.5 concentration (13.2 ± 13.7 µg/m 3 ) was similar to the average measured Grimm 11-R PM 2.5 concentration (11.3 ± 15.1 µg/m 3 ). The overall correlation (r 2 ) for PM 2.5 between the DC 1700 and Grimm 11-R was 0.778. The estimated average coarse PM concentration from the DC 1700 (5.6 ± 12.1 µg/m 3 ) was also similar to that measured with the Grimm 11-R (4.8 ± 16.5 µg/m 3 ) with an r 2 of 0.481. The effects of relative humidity and particle size on the association between the DC 1700 and the Grimm 11-R results were also examined. The calculated PM mass concentrations from the DC 1700 were close to those measured with the Grimm 11-R when relative humidity was less than 60% for both PM 2.5 and coarse PM. Particle size distribution was more important for the association of coarse PM between the DC 1700 and Grimm 11-R than it was for PM 2.5 . The performance of a low-cost particulate matter (PM) sensor was evaluated in an urban residential area. Both PM 2.5 and coarse PM (PM 10-2.5 ) mass concentrations

  14. Self-contained, low-cost Body-on-a-Chip systems for drug development.

    PubMed

    Wang, Ying I; Oleaga, Carlota; Long, Christopher J; Esch, Mandy B; McAleer, Christopher W; Miller, Paula G; Hickman, James J; Shuler, Michael L

    2017-11-01

    Integrated multi-organ microphysiological systems are an evolving tool for preclinical evaluation of the potential toxicity and efficacy of drug candidates. Such systems, also known as Body-on-a-Chip devices, have a great potential to increase the successful conversion of drug candidates entering clinical trials into approved drugs. Systems, to be attractive for commercial adoption, need to be inexpensive, easy to operate, and give reproducible results. Further, the ability to measure functional responses, such as electrical activity, force generation, and barrier integrity of organ surrogates, enhances the ability to monitor response to drugs. The ability to operate a system for significant periods of time (up to 28 d) will provide potential to estimate chronic as well as acute responses of the human body. Here we review progress towards a self-contained low-cost microphysiological system with functional measurements of physiological responses. Impact statement Multi-organ microphysiological systems are promising devices to improve the drug development process. The development of a pumpless system represents the ability to build multi-organ systems that are of low cost, high reliability, and self-contained. These features, coupled with the ability to measure electrical and mechanical response in addition to chemical or metabolic changes, provides an attractive system for incorporation into the drug development process. This will be the most complete review of the pumpless platform with recirculation yet written.

  15. A low-power bio-potential acquisition system with flexible PDMS dry electrodes for portable ubiquitous healthcare applications.

    PubMed

    Chen, Chih-Yuan; Chang, Chia-Lin; Chang, Chih-Wei; Lai, Shin-Chi; Chien, Tsung-Fu; Huang, Hong-Yi; Chiou, Jin-Chern; Luo, Ching-Hsing

    2013-03-04

    This work describes a bio-potential acquisition system for portable ubiquitous healthcare applications using flexible polydimethylsiloxane dry electrodes (FPDEs) and a low-power recording circuit. This novel FPDE used Au as the skin contact layer, which was made using a CO2 laser and replica method technology. The FPDE was revised from a commercial bio-potential electrode with a conductive snap using dry electrodes rather than wet electrodes that proposed reliable and robust attachment for the purpose of measurement, and attaching velcro made it wearable on the forearm for bio-potential applications. Furthermore, this study proposes a recording device to store bio-potential signal data and provides portability and low-power consumption for the proposed acquisition system. To acquire differential bio-potentials, such as electrocardiogram (ECG) signals, the proposed recording device includes a low-power front-end acquisition chip fabricated using a complementary metal-oxide-semiconductor (CMOS) process, a commercial microcontroller (MSP430F149), and a secure digital (SD) card for portable healthcare applications. The proposed system can obtain ECG signals efficiently and are comfortable to the skin. The power consumption of the system is about 85 mW for continuous working over a 3 day period with two AA batteries. It can also be used as a compact Holter ECG system.

  16. A Low-Power Bio-Potential Acquisition System with Flexible PDMS Dry Electrodes for Portable Ubiquitous Healthcare Applications

    PubMed Central

    Chen, Chih-Yuan; Chang, Chia-Lin; Chang, Chih-Wei; Lai, Shin-Chi; Chien, Tsung-Fu; Huang, Hong-Yi; Chiou, Jin-Chern; Luo, Ching-Hsing

    2013-01-01

    This work describes a bio-potential acquisition system for portable ubiquitous healthcare applications using flexible polydimethylsiloxane dry electrodes (FPDEs) and a low-power recording circuit. This novel FPDE used Au as the skin contact layer, which was made using a CO2 laser and replica method technology. The FPDE was revised from a commercial bio-potential electrode with a conductive snap using dry electrodes rather than wet electrodes that proposed reliable and robust attachment for the purpose of measurement, and attaching velcro made it wearable on the forearm for bio-potential applications. Furthermore, this study proposes a recording device to store bio-potential signal data and provides portability and low-power consumption for the proposed acquisition system. To acquire differential bio-potentials, such as electrocardiogram (ECG) signals, the proposed recording device includes a low-power front-end acquisition chip fabricated using a complementary metal-oxide-semiconductor (CMOS) process, a commercial microcontroller (MSP430F149), and a secure digital (SD) card for portable healthcare applications. The proposed system can obtain ECG signals efficiently and are comfortable to the skin. The power consumption of the system is about 85 mW for continuous working over a 3 day period with two AA batteries. It can also be used as a compact Holter ECG system. PMID:23459390

  17. Development of Low Cost, High Energy-Per-Unit-Area Solar Cell Modules

    NASA Technical Reports Server (NTRS)

    Jones, G. T.; Chitre, S.

    1977-01-01

    Work on the development of low cost, high energy per unit area solar cell modules was conducted. Hexagonal solar cell and module efficiencies, module packing ratio, and solar cell design calculations were made. The cell grid structure and interconnection pattern was designed and the module substrates were fabricated for the three modules to be used. It was demonstrated that surface macrostructures significantly improve cell power output and photovoltaic energy conversion efficiency.

  18. Development of a low-cost cellulase production process using Trichoderma reesei for Brazilian biorefineries.

    PubMed

    Ellilä, Simo; Fonseca, Lucas; Uchima, Cristiane; Cota, Junio; Goldman, Gustavo Henrique; Saloheimo, Markku; Sacon, Vera; Siika-Aho, Matti

    2017-01-01

    During the past few years, the first industrial-scale cellulosic ethanol plants have been inaugurated. Although the performance of the commercial cellulase enzymes used in this process has greatly improved over the past decade, cellulases still represent a very significant operational cost. Depending on the region, transport of cellulases from a central production facility to a biorefinery may significantly add to enzyme cost. The aim of the present study was to develop a simple, cost-efficient cellulase production process that could be employed locally at a Brazilian sugarcane biorefinery. Our work focused on two main topics: growth medium formulation and strain improvement. We evaluated several Brazilian low-cost industrial residues for their potential in cellulase production. Among the solid residues evaluated, soybean hulls were found to display clearly the most desirable characteristics. We engineered a Trichoderma reesei strain to secrete cellulase in the presence of repressing sugars, enabling the use of sugarcane molasses as an additional carbon source. In addition, we added a heterologous β-glucosidase to improve the performance of the produced enzymes in hydrolysis. Finally, the addition of an invertase gene from Aspegillus niger into our strain allowed it to consume sucrose from sugarcane molasses directly. Preliminary cost analysis showed that the overall process can provide for very low-cost enzyme with good hydrolysis performance on industrially pre-treated sugarcane straw. In this study, we showed that with relatively few genetic modifications and the right growth medium it is possible to produce considerable amounts of well-performing cellulase at very low cost in Brazil using T. reesei . With further enhancements and optimization, such a system could provide a viable alternative to delivered commercial cellulases.

  19. Low-Cost Servomotor Driver for PFM Control

    PubMed Central

    Aragon-Jurado, David

    2017-01-01

    Servomotors have already been around for some decades and they are extremely popular among roboticists due to their simple control technique, reliability and low-cost. They are usually controlled by using Pulse Width Modulation (PWM) and this paper aims to keep the idea of simplicity and low-cost, while introducing a new control technique: Pulse Frequency Modulation (PFM). The objective of this paper is to focus on our development of a low-cost servomotor controller which will allow the research community to use them with PFM. A low-cost commercial servomotor is used as the base system for the development: a small PCB that fits inside the case and allocates all the electronic components to control the motor has been designed to replace the original. The potentiometer is retained as the feedback sensor and a microcontroller is responsible for controlling the position of the motor. The paper compares the performance of a PWM and a PFM controlled servomotor. The comparison shows that the servomotor with our controller achieves a faster mechanism for switching targets and a lower latency. This controller can be used with neuromorphic systems to remove the conversion from events to PWM. PMID:29301221

  20. Low-Cost Servomotor Driver for PFM Control.

    PubMed

    Aragon-Jurado, David; Morgado-Estevez, Arturo; Perez-Peña, Fernando

    2017-12-31

    Servomotors have already been around for some decades and they are extremely popular among roboticists due to their simple control technique, reliability and low-cost. They are usually controlled by using Pulse Width Modulation (PWM) and this paper aims to keep the idea of simplicity and low-cost, while introducing a new control technique: Pulse Frequency Modulation (PFM). The objective of this paper is to focus on our development of a low-cost servomotor controller which will allow the research community to use them with PFM. A low-cost commercial servomotor is used as the base system for the development: a small PCB that fits inside the case and allocates all the electronic components to control the motor has been designed to replace the original. The potentiometer is retained as the feedback sensor and a microcontroller is responsible for controlling the position of the motor. The paper compares the performance of a PWM and a PFM controlled servomotor. The comparison shows that the servomotor with our controller achieves a faster mechanism for switching targets and a lower latency. This controller can be used with neuromorphic systems to remove the conversion from events to PWM.

  1. Precise time dissemination via portable atomic clocks

    NASA Technical Reports Server (NTRS)

    Putkovich, K.

    1982-01-01

    The most precise operational method of time dissemination over long distances presently available to the Precise Time and Time Interval (PTTI) community of users is by means of portable atomic clocks. The Global Positioning System (GPS), the latest system showing promise of replacing portable clocks for global PTTI dissemination, was evaluated. Although GPS has the technical capability of providing superior world-wide dissemination, the question of present cost and future accessibility may require a continued reliance on portable clocks for a number of years. For these reasons a study of portable clock operations as they are carried out today was made. The portable clock system that was utilized by the U.S. Naval Observatory (NAVOBSY) in the global synchronization of clocks over the past 17 years is described and the concepts on which it is based are explained. Some of its capabilities and limitations are also discussed.

  2. Portable nucleic acid thermocyclers.

    PubMed

    Almassian, David R; Cockrell, Lisa M; Nelson, William M

    2013-11-21

    A nucleic acid thermal cycler is considered to be portable if it is under ten pounds, easily carried by one individual, and battery powered. Nucleic acid amplification includes both polymerase chain reaction (e.g. PCR, RT-PCR) and isothermal amplification (e.g. RPA, HDA, LAMP, NASBA, RCA, ICAN, SMART, SDA). There are valuable applications for portable nucleic acid thermocyclers in fields that include clinical diagnostics, biothreat detection, and veterinary testing. A system that is portable allows for the distributed detection of targets at the point of care and a reduction of the time from sample to answer. The designer of a portable nucleic acid thermocycler must carefully consider both thermal control and the detection of amplification. In addition to thermal control and detection, the designer may consider the integration of a sample preparation subsystem with the nucleic acid thermocycler. There are a variety of technologies that can achieve accurate thermal control and the detection of nucleic acid amplification. Important evaluation criteria for each technology include maturity, power requirements, cost, sensitivity, speed, and manufacturability. Ultimately the needs of a particular market will lead to user requirements that drive the decision between available technologies.

  3. Novel Low-Cost, Low-Power Miniature Thermionic Cathode Developed for Microwave/Millimeter Wave Tube and Cathode Ray Tube Applications

    NASA Technical Reports Server (NTRS)

    Wintucky, Edwin G.

    1999-01-01

    A low cost, small size and mass, low heater power, durable high-performance barium dispenser thermionic cathode has been developed that offers significant advancements in the design, manufacture, and performance of the electron sources used in vacuum electronic devices--such as microwave (and millimeter wave) traveling-wave tubes (TWT's)--and in display devices such as high-brightness, high-resolution cathode ray tubes (CRT's). The lower cathode heater power and the reduced size and mass of the new cathode are expected to be especially beneficial in TWT's for deep space communications, where future missions are requiring smaller spacecraft, higher data transfer rates (higher frequencies and radiofrequency output power), and greater electrical efficiency. Also expected to benefit are TWT's for commercial and government communication satellites, for both low and geosynchronous Earth orbit, with additional benefits offered by lower cost and potentially higher cathode current loading. A particularly important TWT application is in the microwave power module (MPM), which is a hybrid microwave (or millimeter wave) amplifier consisting of a low-noise solid state driver, a vacuum power booster (small TWT), and an electronic power conditioner integrated into a single compact package. The attributes of compactness and potentially high electrical efficiency make the MPM very attractive for many commercial and government (civilian and defense) applications in communication and radar systems. The MPM is already finding application in defense electronic systems and is under development by NASA for deep space communications. However, for the MPM to become competitive and commercially successful, a major reduction in cost must be achieved.

  4. Development of a low cost, low temperature cryocooler using the Gifford McMahon cycle

    NASA Astrophysics Data System (ADS)

    Ramanayaka, A.; Mani, R.

    2008-03-01

    Although Helium is the second most abundant element, its concentration in the earth's atmosphere is fairly low and constant, as the portion that escapes from the atmosphere is replace by new emission. Historically, Helium was extracted as a byproduct of natural gas production, and stored in gas fields in a National Helium Reserve, in an attempt to conserve this interesting element. National policy has changed and the cost of liquid Helium has increased rapidly in the recent past. These new circumstances have created new interest in alternative eco-friendly methods to realizing and maintaining low temperatures in the laboratory. There have been number of successful attempts at making low temperature closed cycle Helium refrigerators by modifying an existing closed cycle system, and usually the regenerator has been replaced in order to achieve the desired results. Here, we discus our attempt to fabricate a low cost, low temperature closed cycle Helium refrigerator starting from a 15K Gifford McMahon system. We reexamine the barriers to realizing lower temperature here and our attempts at overcoming them.

  5. Compact, cost-effective and field-portable microscope prototype based on MISHELF microscopy

    NASA Astrophysics Data System (ADS)

    Sanz, Martín; Picazo-Bueno, José Ángel; Granero, Luis; García, Javier; Micó, Vicente

    2017-02-01

    We report on a reduced cost, portable and compact prototype design of lensless holographic microscope with an illumination/detection scheme based on wavelength multiplexing, working with single hologram acquisition and using a fast convergence algorithm for image processing. All together, MISHELF (initials coming from Multi-Illumination Single-Holographic-Exposure Lensless Fresnel) microscopy allows the recording of three Fresnel domain diffraction patterns in a single camera snap-shot incoming from illuminating the sample with three coherent lights at once. Previous implementations have proposed an illumination/detection procedure based on a tuned (illumination wavelengths centered at the maximum sensitivity of the camera detection channels) configuration but here we report on a detuned (non-centered ones) scheme resulting in prototype miniaturization and cost reduction. Thus, MISHELF microscopy in combination with a novel and fast iterative algorithm allows high-resolution (μm range) phase-retrieved (twin image elimination) quantitative phase imaging of dynamic events (video rate recording speed). The performance of this microscope prototype is validated through experiments using both amplitude (USAF resolution test) and complex (live swine sperm cells and flowing microbeads) samples. The proposed method becomes in an alternative instrument improving some capabilities of existing lensless microscopes.

  6. Compact, cost-effective and field-portable microscope prototype based on MISHELF microscopy

    PubMed Central

    Sanz, Martín; Picazo-Bueno, José Ángel; Granero, Luis; García, Javier; Micó, Vicente

    2017-01-01

    We report on a reduced cost, portable and compact prototype design of lensless holographic microscope with an illumination/detection scheme based on wavelength multiplexing, working with single hologram acquisition and using a fast convergence algorithm for image processing. All together, MISHELF (initials coming from Multi-Illumination Single-Holographic-Exposure Lensless Fresnel) microscopy allows the recording of three Fresnel domain diffraction patterns in a single camera snap-shot incoming from illuminating the sample with three coherent lights at once. Previous implementations have proposed an illumination/detection procedure based on a tuned (illumination wavelengths centered at the maximum sensitivity of the camera detection channels) configuration but here we report on a detuned (non-centered ones) scheme resulting in prototype miniaturization and cost reduction. Thus, MISHELF microscopy in combination with a novel and fast iterative algorithm allows high-resolution (μm range) phase-retrieved (twin image elimination) quantitative phase imaging of dynamic events (video rate recording speed). The performance of this microscope prototype is validated through experiments using both amplitude (USAF resolution test) and complex (live swine sperm cells and flowing microbeads) samples. The proposed method becomes in an alternative instrument improving some capabilities of existing lensless microscopes. PMID:28233829

  7. Low-Cost Large Aperture Telescopes for Optical Communications

    NASA Technical Reports Server (NTRS)

    Hemmati, Hamid

    2006-01-01

    Low-cost, 0.5-1 meter ground apertures are required for near-Earth laser communications. Low-cost ground apertures with equivalent diameters greater than 10 meters are desired for deep-space communications. This presentation focuses on identifying schemes to lower the cost of constructing networks of large apertures while continuing to meet the requirements for laser communications. The primary emphasis here is on the primary mirror. A slumped glass spherical mirror, along with passive secondary mirror corrector and active adaptive optic corrector show promise as a low-cost alternative to large diameter monolithic apertures. To verify the technical performance and cost estimate, development of a 1.5-meter telescope equipped with gimbal and dome is underway.

  8. Portable home hemodialysis for kidney failure.

    PubMed

    Scott, A

    2007-11-01

    (1) Home hemodialysis has been in limited use in Canada for some time. Newer, portable hemodialysis machines that are easier for patients to operate may encourage the uptake of this technology. (2) One portable system is already available in the US. The NxStage System One hemodialysis machine operates on standard electric current, does not require plumbing or specialized disinfection, and is small enough for patients to travel with. (3) It is not yet clear whether the use of the NxStage system improves long-term survival and quality of life. (4) Home hemodialysis is less costly than conventional in-centre programs, but it is unknown whether these savings extend to portable devices.

  9. Ultra Low-Cost Radar

    NASA Astrophysics Data System (ADS)

    Davies, P.; da Silva Curiel, A.; Eves, S.; Sweeting, M.; Thompson, A.; Hall, D.

    From early 2003, Surrey Satellite Technology Limited (SSTL), together with its partners from Algeria, Nigeria and Turkey, has operated the Disaster Monitoring Constellation (DMC). During this period we have demonstrated the utility of a low-cost satellite system that uses optical sensors and is capable of providing daily imaging globally. For example, DMC data has been used operationally in the relief work in Darfur and following the Asian Tsunami. In addition to the use of the DMC to support disasters, the DMC has also been extensively used by the consortium members in support of national imaging needs and some residual system capacity has been provided to commercial customers. In the same timeframe, EADS Astrium Ltd has developed the technologies needed to implement the low-cost radar satellites of the MicroSAR range of synthetic aperture radar (SAR) satellites. EADS Astrium Ltd and SSTL are now looking to combine their expertises in low cost space technology and extend the capability of the DMC constellation by including a complementary small satellite radar sensor. The product of this activity is a satellite design that strikes an appropriate balance between revisit frequency and resolution. Hence, by comparison with other small satellite SAR concepts, the satellite described in this paper will provide broader area coverage at spatial resolutions in the region of 10 - 15m. Most significantly, perhaps, as a result of the specific cost targets imposed at the beginning of the design process, the satellite can provide this level of performance at a lower cost than other comparable space-based radar systems and significantly lower than larger, more performant, space-based radar systems.

  10. Development and Evaluation of A Novel and Cost-Effective Approach for Low-Cost NO2 Sensor Drift Correction

    PubMed Central

    Sun, Li; Westerdahl, Dane; Ning, Zhi

    2017-01-01

    Emerging low-cost gas sensor technologies have received increasing attention in recent years for air quality measurements due to their small size and convenient deployment. However, in the diverse applications these sensors face many technological challenges, including sensor drift over long-term deployment that cannot be easily addressed using mathematical correction algorithms or machine learning methods. This study aims to develop a novel approach to auto-correct the drift of commonly used electrochemical nitrogen dioxide (NO2) sensor with comprehensive evaluation of its application. The impact of environmental factors on the NO2 electrochemical sensor in low-ppb concentration level measurement was evaluated in laboratory and the temperature and relative humidity correction algorithm was evaluated. An automated zeroing protocol was developed and assessed using a chemical absorbent to remove NO2 as a means to perform zero correction in varying ambient conditions. The sensor system was operated in three different environments in which data were compared to a reference NO2 analyzer. The results showed that the zero-calibration protocol effectively corrected the observed drift of the sensor output. This technique offers the ability to enhance the performance of low-cost sensor based systems and these findings suggest extension of the approach to improve data quality from sensors measuring other gaseous pollutants in urban air. PMID:28825633

  11. The smartphone brain scanner: a portable real-time neuroimaging system.

    PubMed

    Stopczynski, Arkadiusz; Stahlhut, Carsten; Larsen, Jakob Eg; Petersen, Michael Kai; Hansen, Lars Kai

    2014-01-01

    Combining low-cost wireless EEG sensors with smartphones offers novel opportunities for mobile brain imaging in an everyday context. Here we present the technical details and validation of a framework for building multi-platform, portable EEG applications with real-time 3D source reconstruction. The system--Smartphone Brain Scanner--combines an off-the-shelf neuroheadset or EEG cap with a smartphone or tablet, and as such represents the first fully portable system for real-time 3D EEG imaging. We discuss the benefits and challenges, including technical limitations as well as details of real-time reconstruction of 3D images of brain activity. We present examples of brain activity captured in a simple experiment involving imagined finger tapping, which shows that the acquired signal in a relevant brain region is similar to that obtained with standard EEG lab equipment. Although the quality of the signal in a mobile solution using an off-the-shelf consumer neuroheadset is lower than the signal obtained using high-density standard EEG equipment, we propose mobile application development may offset the disadvantages and provide completely new opportunities for neuroimaging in natural settings.

  12. The Smartphone Brain Scanner: A Portable Real-Time Neuroimaging System

    PubMed Central

    Stopczynski, Arkadiusz; Stahlhut, Carsten; Larsen, Jakob Eg; Petersen, Michael Kai; Hansen, Lars Kai

    2014-01-01

    Combining low-cost wireless EEG sensors with smartphones offers novel opportunities for mobile brain imaging in an everyday context. Here we present the technical details and validation of a framework for building multi-platform, portable EEG applications with real-time 3D source reconstruction. The system – Smartphone Brain Scanner – combines an off-the-shelf neuroheadset or EEG cap with a smartphone or tablet, and as such represents the first fully portable system for real-time 3D EEG imaging. We discuss the benefits and challenges, including technical limitations as well as details of real-time reconstruction of 3D images of brain activity. We present examples of brain activity captured in a simple experiment involving imagined finger tapping, which shows that the acquired signal in a relevant brain region is similar to that obtained with standard EEG lab equipment. Although the quality of the signal in a mobile solution using an off-the-shelf consumer neuroheadset is lower than the signal obtained using high-density standard EEG equipment, we propose mobile application development may offset the disadvantages and provide completely new opportunities for neuroimaging in natural settings. PMID:24505263

  13. A Portable Impedance Immunosensing System for Rapid Detection of Salmonella Typhimurium

    PubMed Central

    Wen, Tao; Wang, Ronghui; Sotero, America; Li, Yanbin

    2017-01-01

    that is comparable with commercial electrochemical impedance instruments. The developed impedance immunosensor has advantages in portability, low cost, rapid detection and label-free features showing a great potential for in-field detection of foodborne pathogens. PMID:28846643

  14. A Portable Impedance Immunosensing System for Rapid Detection of Salmonella Typhimurium.

    PubMed

    Wen, Tao; Wang, Ronghui; Sotero, America; Li, Yanbin

    2017-08-28

    an LOD that is comparable with commercial electrochemical impedance instruments. The developed impedance immunosensor has advantages in portability, low cost, rapid detection and label-free features showing a great potential for in-field detection of foodborne pathogens.

  15. Portable Wind Energy Harvesters for Low-Power Applications: A Survey.

    PubMed

    Nabavi, Seyedfakhreddin; Zhang, Lihong

    2016-07-16

    Energy harvesting has become an increasingly important topic thanks to the advantages in renewability and environmental friendliness. In this paper, a comprehensive study on contemporary portable wind energy harvesters has been conducted. The electrical power generation methods of portable wind energy harvesters are surveyed in three major groups, piezoelectric-, electromagnetic-, and electrostatic-based generators. The paper also takes another view of this area by gauging the required mechanisms for trapping wind flow from ambient environment. In this regard, rotational and aeroelastic mechanisms are analyzed for the portable wind energy harvesting devices. The comparison between both mechanisms shows that the aeroelastic mechanism has promising potential in producing an energy harvester in smaller scale although how to maintain the resonator perpendicular to wind flow for collecting the maximum vibration is still a major challenge to overcome for this mechanism. Furthermore, this paper categorizes the previously published portable wind energy harvesters to macro and micro scales in terms of their physical dimensions. The power management systems are also surveyed to explore the possibility of improving energy conversion efficiency. Finally some insights and research trends are pointed out based on an overall analysis of the previously published works along the historical timeline.

  16. Development and validation of a low-cost mobile robotics testbed

    NASA Astrophysics Data System (ADS)

    Johnson, Michael; Hayes, Martin J.

    2012-03-01

    This paper considers the design, construction and validation of a low-cost experimental robotic testbed, which allows for the localisation and tracking of multiple robotic agents in real time. The testbed system is suitable for research and education in a range of different mobile robotic applications, for validating theoretical as well as practical research work in the field of digital control, mobile robotics, graphical programming and video tracking systems. It provides a reconfigurable floor space for mobile robotic agents to operate within, while tracking the position of multiple agents in real-time using the overhead vision system. The overall system provides a highly cost-effective solution to the topical problem of providing students with practical robotics experience within severe budget constraints. Several problems encountered in the design and development of the mobile robotic testbed and associated tracking system, such as radial lens distortion and the selection of robot identifier templates are clearly addressed. The testbed performance is quantified and several experiments involving LEGO Mindstorm NXT and Merlin System MiaBot robots are discussed.

  17. A Low Cost TDRSS Compatible Transmitter Option

    NASA Technical Reports Server (NTRS)

    Whiteman, Don

    2005-01-01

    The NASA Space-based Telemetry and Range Safety (STARS) program has developed and tested a low cost Ku-Band transmitter alternative for TDRSS applications based on an existing IRIG shaped offset quaternary phase shift keying (SOQPSK) transmitter. This paper presents information related to the implementation of this low cost system, as well as performance measurements of the alternative TDRSS transmitter system compared with an existing QPSK TDRSS transmitter.

  18. Shock experiments and numerical simulations on low energy portable electrically exploding foil accelerators

    NASA Astrophysics Data System (ADS)

    Saxena, A. K.; Kaushik, T. C.; Gupta, Satish C.

    2010-03-01

    Two low energy (1.6 and 8 kJ) portable electrically exploding foil accelerators are developed for moderately high pressure shock studies at small laboratory scale. Projectile velocities up to 4.0 km/s have been measured on Kapton flyers of thickness 125 μm and diameter 8 mm, using an in-house developed Fabry-Pérot velocimeter. An asymmetric tilt of typically few milliradians has been measured in flyers using fiber optic technique. High pressure impact experiments have been carried out on tantalum, and aluminum targets up to pressures of 27 and 18 GPa, respectively. Peak particle velocities at the target-glass interface as measured by Fabry-Pérot velocimeter have been found in good agreement with the reported equation of state data. A one-dimensional hydrodynamic code based on realistic models of equation of state and electrical resistivity has been developed to numerically simulate the flyer velocity profiles. The developed numerical scheme is validated against experimental and simulation data reported in literature on such systems. Numerically computed flyer velocity profiles and final flyer velocities have been found in close agreement with the previously reported experimental results with a significant improvement over reported magnetohydrodynamic simulations. Numerical modeling of low energy systems reported here predicts flyer velocity profiles higher than experimental values, indicating possibility of further improvement to achieve higher shock pressures.

  19. Development of Low Cost Soil Stabilization Using Recycled Material

    NASA Astrophysics Data System (ADS)

    Ahmad, F.; Yahaya, A. S.; Safari, A.

    2016-07-01

    Recycled tyres have been used in many geotechnical engineering projects such as soil improvement, soil erosion and slope stability. Recycled tyres mainly in chip and shredded form are highly compressible under low and normal pressures. This characteristic would cause challenging problems in some applications of soil stabilization such as retaining wall and river bank projects. For high tensile stress and low tensile strain the use of fiberglass would be a good alternative for recycled tyre in some cases. To evaluate fiberglass as an alternative for recycled tyre, this paper focused on tests of tensile tests which have been carried out between fiberglass and recycled tyre strips. Fibreglass samples were produced from chopped strand fibre mat, a very low-cost type of fibreglass, which is cured by resin and hardener. Fibreglass samples in the thickness of 1 mm, 2 mm, 3 mm and 4 mm were developed 100 mm x 300 mm pieces. It was found that 3 mm fibreglass exhibited the maximum tensile load (MTL) and maximum tensile stress (MTS) greater than other samples. Statistical analysis on 3 mm fibreglass indicated that in the approximately equal MTL fibreglass samples experienced 2% while tyre samples experienced 33.9% ultimate tensile strain (UTST) respectively. The results also showed an approximately linear relationship between stress and strain for fibreglass samples and Young's modulus (E), ranging from 3581 MPa to 4728 MPa.

  20. Development costs of reusable launch vehicles

    NASA Astrophysics Data System (ADS)

    Koelle, D.

    2002-07-01

    The paper deals first with the definition and understanding of "Development Costs" in general. Usually there is large difference between initial "development cost guesses", "Proposal Cost Estimations" and the final "Cost-to-Completion". The reasons for the usual development cost increases during development are discussed. The second part discusses the range of historic launch systems' development costs under "Business-as-Usual" (BaU) - Conditions and potential cost reductions for future developments of RLVs, as well as the comparison to commercial, industrial development cost. Part three covers the potential reduction of development cost by application of "Cost Engineering Principles". An example of the large potential cost range (between 6 and 17 Billion USD) for the development of the same winged rocket-propelled SSTO launch vehicle concept is presented. Finally the tremendous development cost differences are shown which exist for the different potential Reusable Launch System Options which are under discussion. There remains an unresolved problem between the primary goals of the national space agencies with emphasis on new technology development/national prestige and the commercial market requirement of a simple low-cost RLV-System.

  1. Portable Instrument to Measure CDOM Light Absorption in Aquatic Systems: WPI Success Story

    NASA Technical Reports Server (NTRS)

    2001-01-01

    World Precision Instruments, Inc. (WPI), of Sarasota, FL, in collaboration with NASA's John C. Stennis Space Center, has developed an innovative instrument to accurately measure Colored Dissolved Organic Matter (CDOM) absorption in the field. This successful collaboration has culminated in an exciting new device, called the UltraPath, now commercially available through WPI. Traditional methods of measuring absorption of dissolved materials require special handling and storage prior to measurement. Use of laboratory spectrophotometers as the measuring devices have proven time consuming, cumbersome, and delicate to handle. The UltraPath provides a low-cost, highly sensitive, rugged, portable system that is capable of high sensitivity measurements in widely divergent waters.

  2. Portable Fluorescence Imaging System for Hypersonic Flow Facilities

    NASA Technical Reports Server (NTRS)

    Wilkes, J. A.; Alderfer, D. W.; Jones, S. B.; Danehy, P. M.

    2003-01-01

    A portable fluorescence imaging system has been developed for use in NASA Langley s hypersonic wind tunnels. The system has been applied to a small-scale free jet flow. Two-dimensional images were taken of the flow out of a nozzle into a low-pressure test section using the portable planar laser-induced fluorescence system. Images were taken from the center of the jet at various test section pressures, showing the formation of a barrel shock at low pressures, transitioning to a turbulent jet at high pressures. A spanwise scan through the jet at constant pressure reveals the three-dimensional structure of the flow. Future capabilities of the system for making measurements in large-scale hypersonic wind tunnel facilities are discussed.

  3. High resolution, low cost solar cell contact development

    NASA Technical Reports Server (NTRS)

    Mardesich, N.

    1981-01-01

    The MIDFILM cell fabrication and encapsulation processes were demonstrated as a means of applying low-cost solar cell collector metallization. The average cell efficiency of 12.0 percent (AM1, 28 C) was achieved with fritted silver metallization with a demonstration run of 500 starting wafers. A 98 percent mechanical yield and 80 percent electrical yield were achieved through the MIDFILM process. High series resistance was responsible for over 90 percent of the electrical failures and was the major factor causing the low average cell efficiency. Environmental evaluations suggest that the MIDFILM cells do not degrade. A slight degradation in power was experienced in the MIDFILM minimodules when the AMP Solarlok connector delaminated during the environmental testing.

  4. [Advances of portable electrocardiogram monitor design].

    PubMed

    Ding, Shenping; Wang, Yinghai; Wu, Weirong; Deng, Lingli; Lu, Jidong

    2014-06-01

    Portable electrocardiogram monitor is an important equipment in the clinical diagnosis of cardiovascular diseases due to its portable, real-time features. It has a broad application and development prospects in China. In the present review, previous researches on the portable electrocardiogram monitors have been arranged, analyzed and summarized. According to the characteristics of the electrocardiogram (ECG), this paper discusses the ergonomic design of the portable electrocardiogram monitor, including hardware and software. The circuit components and software modules were parsed from the ECG features and system functions. Finally, the development trend and reference are provided for the portable electrocardiogram monitors and for the subsequent research and product design.

  5. Development of low cost medium for ethanol production from syngas by Clostridium ragsdalei.

    PubMed

    Gao, Jie; Atiyeh, Hasan K; Phillips, John R; Wilkins, Mark R; Huhnke, Raymond L

    2013-11-01

    The development of a low cost medium for ethanol production is critical for process feasibility. Ten media were formulated for Clostridium ragsdalei by reduction, elimination and replacement of expensive nutrients. Cost analysis and effects of medium components on growth and product formation were investigated. Fermentations were performed in 250 mL bottles using syngas (20% CO, 15% CO2, 5% H2 and 60% N2). The standard medium M1 cost is $9.83/L, of which 93% is attributed to morpholinoethane sulfonic acid (MES) buffer. Statistical analysis of the results showed that MES removal did not affect cell growth and ethanol production (P>0.05). Based on cells' elemental composition, a minimal mineral concentration medium M7 was formulated, which provided 29% higher ethanol yield from CO at 3% of the cost compared to medium M1. Ethanol yield from CO in the completely defined medium M9 was 36% higher than while at 5% the cost of medium M1. Copyright © 2013 Elsevier Ltd. All rights reserved.

  6. Portable DMFC system with methanol sensor-less control

    NASA Astrophysics Data System (ADS)

    Chen, C. Y.; Liu, D. H.; Huang, C. L.; Chang, C. L.

    This work develops a prototype 20 W portable DMFC by system integration of stack, condenser, methanol sensor-less control and start-up characteristics. The effects of these key components and control schemes on the performance are also discussed. To expedite the use of portable DMFC in electronic applications, the system utilizes a novel methanol sensor-less control method, providing improved fuel efficiency, durability, miniaturization and cost reduction. The operating characteristics of the DMFC stack are applied to control the fuel ejection time and period, enabling the system to continue operating even when the MEAs of the stack are deteriorated. The portable system is also designed with several features including water balance and quick start-up (in 5 min). Notably, the proposed system using methanol sensor-less control with injection of pure methanol can power the DVD player and notebook PC. The system specific energy and energy density following three days of operation are 362 Wh kg -1 and 335 Wh L -1, respectively, which are better than those of lithium batteries (∼150 Wh kg -1 and ∼250 Wh L -). This good energy storage feature demonstrates that the portable DMFC is likely to be valuable in computer, communication and consumer electronic (3C) markets.

  7. Development of a low-cost detection method for miRNA microarray.

    PubMed

    Li, Wei; Zhao, Botao; Jin, Youxin; Ruan, Kangcheng

    2010-04-01

    MicroRNA (miRNA) microarray is a powerful tool to explore the expression profiling of miRNA. The current detection method used in miRNA microarray is mainly fluorescence based, which usually requires costly detection system such as laser confocal scanner of tens of thousands of dollars. Recently, we developed a low-cost yet sensitive detection method for miRNA microarray based on enzyme-linked assay. In this approach, the biotinylated miRNAs were captured by the corresponding oligonucleotide probes immobilized on microarray slide; and then the biotinylated miRNAs would capture streptavidin-conjugated alkaline phosphatase. A purple-black precipitation on each biotinylated miRNA spot was produced by the enzyme catalytic reaction. It could be easily detected by a charge-coupled device digital camera mounted on a microscope, which lowers the detection cost more than 100 fold compared with that of fluorescence method. Our data showed that signal intensity of the spot correlates well with the biotinylated miRNA concentration and the detection limit for miRNAs is at least 0.4 fmol and the detection dynamic range spans about 2.5 orders of magnitude, which is comparable to that of fluorescence method.

  8. Portable bladder ultrasound: an evidence-based analysis.

    PubMed

    2006-01-01

    alternative to catheterization. An economic analysis estimating the budget-impact of BladderScan in complex continuing care facilities was completed. The analysis results indicated a $192,499 (Cdn) cost-savings per year per facility and a cost-savings of $2,887,485 (Cdn) for all 15 CCC facilities. No economic analysis was completed for long-term care and acute care facilities due to lack of data. Rapid diffusion of portable bladder ultrasound technology is expected. Recently, the IC5 project on improving continence care in Ontario's complex continuing care centres piloted portable bladder ultrasound at 12 sites. Preliminary results were promising. Many physicians and health care facilities already have portable bladder ultrasound devices. However, portable bladder ultrasound devices for PVR measurement are not in use at most health care facilities in Ontario and Canada. The Verathon Corporation (Bothell, Wisconsin, United States), which patents BladderScan, is the sole licensed manufacturer of the portable bladder ultrasound in Canada. Field monopoly may influence the rising costs of portable bladder ultrasound, particularly when faced with rapid expansion of the technology. Several thousand residents of Ontario would benefit from portable bladder ultrasound. The number of residents of Ontario that would benefit from the technology is difficult to quantify, because the incidence and prevalence of incontinence are grossly under-reported. However, long-term care and complex continuing care institutions would benefit greatly from portable bladder ultrasound, as would numerous rehabilitation units, postsurgical care units, and urology clinics. The cost of the portable bladder ultrasound devices ranges from $17,698.90 to $19,565.95 (Cdn) (total purchase price per unit as quoted by the manufacturer). Additional training packages, batteries and battery chargers, software, gel pads, and yearly warranties are additional costs. Studies indicate that portable bladder ultrasound is a

  9. Low-Cost Rescue Robot for Disaster Management in a Developing Country: Development of a Prototype Using Locally Available Technology

    NASA Technical Reports Server (NTRS)

    Mahmud, Faisal; Hossain, S. G. M.; Bin, Jobair

    2010-01-01

    The use of robots in different fields is common and effective in developed countries. In case of incident management or emergency rescue after a disaster, robots are often used to lessen the human effort where it is either impossible or life-threatening for rescuers. Though developed countries can afford robotic-effort for pro-disaster management, the scenario is totally opposite for developing and under-developed countries to engage such a machine-help due to high cost of the machines and high maintenance cost as well. In this research paper, the authors proposed a low-cost "Rescue-Robot" for pro-disaster management which can overcome the budget-constraints as well as fully capable of rescue purposes for incident management. Here, all the research works were performed in Bangladesh - a developing country in South Asia. A disaster struck structure was chosen and a thorough survey was performed to understand the real-life environment for the prototype. The prototype was developed considering the results of this survey and it was manufactured using all locally available components and facilities.

  10. Portable low-cost devices for videotaping, editing, and displaying field-sequential stereoscopic motion pictures and video

    NASA Astrophysics Data System (ADS)

    Starks, Michael R.

    1990-09-01

    A variety of low cost devices for capturing, editing and displaying field sequential 60 cycle stereoscopic video have recently been marketed by 3D TV Corp. and others. When properly used, they give very high quality images with most consumer and professional equipment. Our stereoscopic multiplexers for creating and editing field sequential video in NTSC or component(SVHS, Betacain, RGB) and Home 3D Theater system employing LCD eyeglasses have made 3D movies and television available to a large audience.

  11. Portable low-coherence interferometry for quantitatively imaging fast dynamics with extended field of view

    NASA Astrophysics Data System (ADS)

    Shaked, Natan T.; Girshovitz, Pinhas; Frenklach, Irena

    2014-06-01

    We present our recent advances in the development of compact, highly portable and inexpensive wide-field interferometric modules. By a smart design of the interferometric system, including the usage of low-coherence illumination sources and common-path off-axis geometry of the interferometers, spatial and temporal noise levels of the resulting quantitative thickness profile can be sub-nanometric, while processing the phase profile in real time. In addition, due to novel experimentally-implemented multiplexing methods, we can capture low-coherence off-axis interferograms with significantly extended field of view and in faster acquisition rates. Using these techniques, we quantitatively imaged rapid dynamics of live biological cells including sperm cells and unicellular microorganisms. Then, we demonstrated dynamic profiling during lithography processes of microscopic elements, with thicknesses that may vary from several nanometers to hundreds of microns. Finally, we present new algorithms for fast reconstruction (including digital phase unwrapping) of off-axis interferograms, which allow real-time processing in more than video rate on regular single-core computers.

  12. A portable meter for measuring low frequency currents in the human body.

    PubMed

    Niple, J C; Daigle, J P; Zaffanella, L E; Sullivan, T; Kavet, R

    2004-07-01

    A portable meter has been developed for measuring low frequency currents that flow in the human body. Although the present version of the meter was specifically designed to measure 50/60 Hz "contact currents," the principles involved can be used with other low frequency body currents. Contact currents flow when the human body provides a conductive path between objects in the environment with different electrical potentials. The range of currents the meter detects is approximately 0.4-800 microA. This provides measurements of currents from the threshold of human perception (approximately 500 microA(RMS)) down to single microampere levels. The meter has a unique design, which utilizes the human subject's body impedance as the sensing element. Some of the advantages of this approach are high sensitivity, the ability to measure current flow in the majority of the body, and relative insensitivity to the current path connection points. Current measurement accuracy varies with the accuracy of the body impedance (resistance) measurement and different techniques can be used to obtain a desired level of accuracy. Techniques are available to achieve an estimated +/-20% accuracy. Copyright 2004 Wiley-Liss, Inc.

  13. Portable Wind Energy Harvesters for Low-Power Applications: A Survey

    PubMed Central

    Nabavi, Seyedfakhreddin; Zhang, Lihong

    2016-01-01

    Energy harvesting has become an increasingly important topic thanks to the advantages in renewability and environmental friendliness. In this paper, a comprehensive study on contemporary portable wind energy harvesters has been conducted. The electrical power generation methods of portable wind energy harvesters are surveyed in three major groups, piezoelectric-, electromagnetic-, and electrostatic-based generators. The paper also takes another view of this area by gauging the required mechanisms for trapping wind flow from ambient environment. In this regard, rotational and aeroelastic mechanisms are analyzed for the portable wind energy harvesting devices. The comparison between both mechanisms shows that the aeroelastic mechanism has promising potential in producing an energy harvester in smaller scale although how to maintain the resonator perpendicular to wind flow for collecting the maximum vibration is still a major challenge to overcome for this mechanism. Furthermore, this paper categorizes the previously published portable wind energy harvesters to macro and micro scales in terms of their physical dimensions. The power management systems are also surveyed to explore the possibility of improving energy conversion efficiency. Finally some insights and research trends are pointed out based on an overall analysis of the previously published works along the historical timeline. PMID:27438834

  14. Development of Manufacturing Technology to Accelerate Cost Reduction of Low Concentration and

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Detrick, Adam

    The purpose of this project was to accelerate deployment of cost-effective US-based manufacturing of Solaria’s unique c-Si module technology. This effort successfully resulted in the development of US-based manufacturing technology to support two highly-differentiated, market leading product platforms. The project was initially predicated on developing Solaria’s low-concentration PV (LCPV) module technology which at the time of the award was uniquely positioned to exceed the SunShot price goal of $0.50/Wp for standard c-Si modules. The Solaria LCPV module is a 2.5x concentrator that leverages proven, high-reliability PV module materials and low silicon cell usage into a technology package that already hadmore » the lowest direct material cost and leading Levelized Cost of Electricity (LCOE). With over 25 MW commercially deployed globally, the Solaria module was well positioned to continue to lead in PV module cost reduction. Throughout the term of the contract, market conditions changed dramatically and so to did Solaria’s product offerings to support this. However, the manufacturing technology developed for the LCPV module was successfully leveraged and optimized to support two new and different product platforms. BIPV “PowerVision” and High-efficiency “PowerXT” modules. The primary barrier to enabling high-volume PV module manufacturing in the US is the high manual labor component in certain unique aspects of our manufacturing process. The funding was used to develop unique manufacturing automation which makes the manual labor components of these key processes more efficient and increase throughput. At the core of Solaria’s product offerings are its unique and proprietary techniques for dicing and re-arranging solar cells into modules with highly-differentiated characteristics that address key gaps in the c-Si market. It is these techniques that were successfully evolved and deployed into US-based manufacturing site with SunShot funding. Today

  15. 10 CFR 440.20 - Low-cost/no-cost weatherization activities.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 3 2010-01-01 2010-01-01 false Low-cost/no-cost weatherization activities. 440.20 Section 440.20 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION WEATHERIZATION ASSISTANCE FOR LOW-INCOME PERSONS § 440.20 Low-cost/no-cost weatherization activities. (a) An eligible dwelling unit may be...

  16. Intelligent hand-portable proliferation sensing system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dieckman, S.L.; Bostrom, G.A.; Waterfield, L.G.

    1997-08-01

    Argonne National Laboratory, with support from DOE`s Office of Nonproliferation and National Security, is currently developing an intelligent hand-portable sensor system. This system is designed specifically to support the intelligence community with the task of in-field sensing of nuclear proliferation and related activities. Based upon pulsed laser photo-ionization time-of-flight mass spectrometry technology, this novel sensing system is capable of quickly providing a molecular or atomic analysis of specimens. The system is capable of analyzing virtually any gas phase molecule, or molecule that can be induced into the gas phase by (for example) sample heating. This system has the unique advantagesmore » of providing unprecedented portability, excellent sensitivity, tremendous fieldability, and a high performance/cost ratio. The system will be capable of operating in a highly automated manner for on-site inspections, and easily modified for other applications such as perimeter monitoring aboard a plane or drone. The paper describes the sensing system.« less

  17. A single FPGA-based portable ultrasound imaging system for point-of-care applications.

    PubMed

    Kim, Gi-Duck; Yoon, Changhan; Kye, Sang-Bum; Lee, Youngbae; Kang, Jeeun; Yoo, Yangmo; Song, Tai-kyong

    2012-07-01

    We present a cost-effective portable ultrasound system based on a single field-programmable gate array (FPGA) for point-of-care applications. In the portable ultrasound system developed, all the ultrasound signal and image processing modules, including an effective 32-channel receive beamformer with pseudo-dynamic focusing, are embedded in an FPGA chip. For overall system control, a mobile processor running Linux at 667 MHz is used. The scan-converted ultrasound image data from the FPGA are directly transferred to the system controller via external direct memory access without a video processing unit. The potable ultrasound system developed can provide real-time B-mode imaging with a maximum frame rate of 30, and it has a battery life of approximately 1.5 h. These results indicate that the single FPGA-based portable ultrasound system developed is able to meet the processing requirements in medical ultrasound imaging while providing improved flexibility for adapting to emerging POC applications.

  18. Development of Low-Cost Inverted Microscope to Detect Early Growth of Mycobacterium tuberculosis in MODS Culture

    PubMed Central

    Zimic, Mirko; Velazco, Abner; Comina, Germán; Coronel, Jorge; Fuentes, Patricia; Luna, Carmen G.; Sheen, Patricia; Gilman, Robert H.; Moore, David A. J.

    2010-01-01

    Background The microscopic observation drug susceptibility (MODS) assay for rapid, low-cost detection of tuberculosis and multidrug resistant tuberculosis depends upon visualization of the characteristic cording colonies of Mycobacterium tuberculosis in liquid media. This has conventionally required an inverted light microscope in order to inspect the MODS culture plates from below. Few tuberculosis laboratories have this item and the capital cost of $5,000 for a high-end microscope could be a significant obstacle to MODS roll-out. Methodology We hypothesized that the precise definition provided by costly high-specification inverted light microscopes might not be necessary for pattern recognition. Significance In this work we describe the development of a low-cost artesenal inverted microscope that can operate in both a standard or digital mode to effectively replace the expensive commercial inverted light microscope, and an integrated system that could permit a local and remote diagnosis of tuberculosis. PMID:20351778

  19. Low cost miniature data collection platform

    NASA Technical Reports Server (NTRS)

    1977-01-01

    The development of the RF elements of a telecommunications package involved detailed study and analysis of concepts and techniques followed by laboratory testing and evaluation of designs. The design goals for a complete telecommunications package excluding antenna were a total weight of 300 grams, in a total volume of 400 cu cm with a capability of unattended operation for a period of six months. Of utmost importance is extremely low cost when produced in lots of 10,000. Early in the program it became apparent that a single Miniature Data Collection Platform would not satisfy all users. A single high efficiency system would not satisfy a user who had available a large battery capacity but required a low cost system. Conversely, the low cost system would not satisfy the end user who had a very limited battery capacity. A system design to satisfy these varied requirements was implemented by designing several versions of the system building blocks and then constructing three systems from these building blocks.

  20. Low Cost Large Core Vehicle Structures Assessment

    NASA Technical Reports Server (NTRS)

    Hahn, Steven E.

    1998-01-01

    Boeing Information, Space, and Defense Systems executed a Low Cost Large Core Vehicle Structures Assessment (LCLCVSA) under contract to NASA Marshall Space Flight Center (MSFC) between November 1997 and March 1998. NASA is interested in a low-cost launch vehicle, code named Magnum, to place heavy payloads into low earth orbit for missions such as a manned mission to Mars, a Next Generation Space Telescope, a lunar-based telescope, the Air Force's proposed space based laser, and large commercial satellites. In this study, structural concepts with the potential to reduce fabrication costs were evaluated in application to the Magnum Launch Vehicle (MLV) and the Liquid Fly Back Booster (LFBB) shuttle upgrade program. Seventeen concepts were qualitatively evaluated to select four concepts for more in-depth study. The four structural concepts selected were: an aluminum-lithium monocoque structure, an aluminum-lithium machined isogrid structure, a unitized composite sandwich structure, and a unitized composite grid structure. These were compared against a baseline concept based on the Space Shuttle External Tank (ET) construction. It was found that unitized composite structures offer significant cost and weight benefits to MLV structures. The limited study of application to LFBB structures indicated lower, but still significant benefits. Technology and facilities development roadmaps to prepare the approaches studied for application to MLV and LFBB were constructed. It was found that the cost and schedule to develop these approaches were in line with both MLV and LFBB development schedules. Current Government and Boeing programs which address elements of the development of the technologies identified are underway. It is recommended that NASA devote resources in a timely fashion to address the specific elements related to MLV and LFBB structures.

  1. DEMONSTRATION OF LOW COST, LOW BURDEN EXPOSURE MONITORING STRATEGIES - BIRTH COHORT

    EPA Science Inventory

    This study was designed to develop and demonstrate relevant, low cost, low burden monitoring strategies that can be used in a longitudinal epidemiological study that focuses on pregnant women and young children. The focus of this study was on (1) recruiting and retaining partici...

  2. Achieving appropriate design for developing world heath care: the case of a low-cost autoclave for primary health clinics.

    PubMed

    Cho, Hallie S; Tao, Gregory D; Winter, Amos

    2012-01-01

    In developing world health clinics, incidence of surgical site infection is 2 to 10 times higher than in developed world hospitals. This paper identifies lack of availability of appropriately designed, low-cost autoclaves in developing world health clinics as a major contributing factor to the dramatic gap in surgical site infection rates. The paper describes the process of developing a low-cost autoclave that addresses the unique challenges faced by developing world primary health clinics and discusses how appropriateness of design was determined. The resulting pressure cooker-based autoclave design was fabricated and tested against the CDC specifications. Twelve partnering clinics in Nepal trialed these autoclaves from July until December 2012.

  3. Low-cost solar array project progress and plans

    NASA Technical Reports Server (NTRS)

    Callaghan, W. T.

    1981-01-01

    The considered project is part of the DOE Photovoltaic Technology and Market Development Program. This program is concerned with the development and the utilization of cost-competitive photovoltaic systems. The project has the objective to develop, by 1986, the national capability to manufacture low-cost, long-life photovoltaic arrays at production rates that will realize economies of scale, and at a price of less than $0.70/watt. The array performance objectives include an efficiency greater than 10% and an operating lifetime longer than 20 years. The objective of the silicon material task is to establish the practicality of processes for producing silicon suitable for terrestrial photovoltaic applications at a price of $14/kg. The large-area sheet task is concerned with the development of process technology for sheet formation. Low-cost encapsulation material systems are being developed in connection with the encapsulation task. Another project goal is related to the development of economical process sequences.

  4. Electrostatic actuators for portable microfluidic systems

    NASA Astrophysics Data System (ADS)

    Tice, Joshua

    Both developed and developing nations have an urgent need to diagnose disease cheaply, reliably, and independently of centralized facilities. Microfulidic platforms are well-positioned to address the need for portable diagnostics, mainly due to their obvious advantage in size. However, most microfluidic methods rely on equipment outside of the chip either for driving fluid flow (e.g., syringe pumps) or for taking measurements (e.g., lasers or microscopes). The energy and space requirements of the whole system inhibit portability and contribute to costs. To capitalize on the strengths of microfluidic platforms and address the serious needs of society, system components need to be miniaturized. Also, miniaturization should be accomplished as simply as possible, considering that simplicity is usually requisite for achieving truly transformative technology. Herein, I attempt to address the issue of controlling fluid flow in portable microfluidic systems. I focus on systems that are driven by elastomer-based membrane valves, since these valves are inherently simple, yet they are capable of sophisticated fluid manipulation. Others have attempted to modify pneumatic microvalves for portable applications, e.g., by transitioning to electromagnetic, thermopneumatic, or piezoelectric actuation principles. However, none of these strategies maintain the proper balance of simplicity, functionality, and ease of integration. My research centers on electrostatic actuators, due to their conceptual simplicity and the efficacy of electrostatic forces on the microscale. To ensure easy integration with polymer-based systems, and to maintain simplicity in the fabrication procedure, the actuators were constructed solely from poly(dimethylsiloxane) and multi-walled carbon nanotubes. In addition, the actuators were fabricated exclusively with soft-lithographic techniques. A mathematical model was developed to identify actuator parameters compatible with soft-lithography, and also to

  5. Low-Cost Inkjet Printing Technology for the Rapid Prototyping of Transducers

    PubMed Central

    Andò, Bruno; Baglio, Salvatore; Bulsara, Adi R.; Emery, Teresa; Marletta, Vincenzo; Pistorio, Antonio

    2017-01-01

    Recently, there has been an upsurge in efforts dedicated to developing low-cost flexible electronics by exploiting innovative materials and direct printing technologies. This interest is motivated by the need for low-cost mass-production, shapeable, and disposable devices, and the rapid prototyping of electronics and sensors. This review, following a short overview of main printing processes, reports examples of the development of flexible transducers through low-cost inkjet printing technology. PMID:28368318

  6. Simultaneous determination of low-molecular-weight organic acids and chlorinated acid herbicides in environmental water by a portable CE system with contactless conductivity detection.

    PubMed

    Xu, Yan; Wang, Weilong; Li, Sam Fong Yau

    2007-05-01

    This report describes a method to simultaneously determine 11 low-molecular-weight (LMW) organic acids and 16 chlorinated acid herbicides within a single run by a portable CE system with contactless conductivity detection (CCD) in a poly(vinyl alcohol) (PVA)-coated capillary. Under the optimized condition, the LODs of CE-CCD ranged from 0.056 to 0.270 ppm, which were better than for indirect UV (IUV) detection of the 11 LMW organic acids or UV detection of the 16 chlorinated acid herbicides. Combined with an on-line field-amplified sample stacking (FASS) procedure, sensitivity enhancement of 632- to 1078-fold was achieved, with satisfactory reproducibility (RSDs of migration times less than 2.2%, and RSDs of peak areas less than 5.1%). The FASS-CE-CCD method was successfully applied to determine the two groups of acidic pollutants in two kinds of environmental water samples. The portable CE-CCD system shows advantages such as simplicity, cost effectiveness, and miniaturization. Therefore, the method presented in this report has great potential for onsite analysis of various pollutants at the trace level.

  7. Development of a portable bicycle/pedestrian monitoring system for safety enhancement.

    DOT National Transportation Integrated Search

    2017-02-02

    The objective of this project was to develop a portable automated system to collect continuous video data on pedestrian and cyclist behavior at midblock locations throughout the metro Atlanta area. The system analyzes the collected video data and aut...

  8. Designing a Low-Cost Multifunctional Infant Incubator.

    PubMed

    Tran, Kevin; Gibson, Aaron; Wong, Don; Tilahun, Dagmawi; Selock, Nicholas; Good, Theresa; Ram, Geetha; Tolosa, Leah; Tolosa, Michael; Kostov, Yordan; Woo, Hyung Chul; Frizzell, Michael; Fulda, Victor; Gopinath, Ramya; Prasad, J Shashidhara; Sudarshan, Hanumappa; Venkatesan, Arunkumar; Kumar, V Sashi; Shylaja, N; Rao, Govind

    2014-06-01

    Every year, an unacceptably large number of infant deaths occur in developing nations, with premature birth and asphyxia being two of the leading causes. A well-regulated thermal environment is critical for neonatal survival. Advanced incubators currently exist, but they are far too expensive to meet the needs of developing nations. We are developing a thermodynamically advanced low-cost incubator suitable for operation in a low-resource environment. Our design features three innovations: (1) a disposable baby chamber to reduce infant mortality due to nosocomial infections, (2) a passive cooling mechanism using low-cost heat pipes and evaporative cooling from locally found clay pots, and (3) insulated panels and a thermal bank consisting of water that effectively preserve and store heat. We developed a prototype incubator and visited and presented our design to our partnership hospital site in Mysore, India. After obtaining feedback, we have determined realistic, nontrivial design requirements and constraints in order to develop a new prototype incubator for clinical trials in hospitals in India. © 2014 Society for Laboratory Automation and Screening.

  9. Low-cost safety enhancements for stop-controlled and signalized intersections

    DOT National Transportation Integrated Search

    2009-05-01

    The purpose of this document is to present information on suggested effective, low-cost intersection countermeasures developed using intersection safety research results and input from an intersection safety expert panel. These low-cost countermeasur...

  10. Development of Low Temperature Li-Ion Electrolytes for NASA and DoD Applications

    NASA Technical Reports Server (NTRS)

    Smart, M.; Ratnakumar, B.; Surampudi, S.; Plichta, E.; Hendrickson, M.; Thompson, R.; Au, G.; Behl, W.

    1999-01-01

    Both NASA and the U.S. Army have interest in developing secondary energy storage devices with improved low temperature performance to meet the demanding requirements of space missions and man-portable applications.

  11. Problems and Issues of High Rise Low Cost Housing in Malaysia

    NASA Astrophysics Data System (ADS)

    Wahi, Noraziah; Mohamad Zin, Rosli; Munikanan, Vikneswaran; Mohamad, Ismail; Junaini, Syahrizan

    2018-03-01

    Major cities in developing countries are undergoing an enormous migration of peoples from countryside regions. This migration from the countryside regions were mostly to develop carrier and expecting for higher salary for their living survival. Consequently, the large amount of immigrants from countryside to the cities each year had created a great demand for urban housing. The impact from that, Kuala Lumpur, Selangor and its surrounding area now is crowded by the low-income group who cannot afford to own an affordable house. The government of Malaysia had aware of this situation and therefore had created the low cost housing especially for urban poor. However, there are many issues and problems arise regarding the low cost housing in Malaysia especially in urban area. The research is regarding a study on problems and issues of high rise low-cost housing in Malaysia. The need to examine the problems associated with the high rise low cost housing is to ensure the success of future low cost housing development in Malaysia.

  12. Development and Validation of a Collocated Exposure Monitoring Methodology using Portable Air Monitors

    NASA Astrophysics Data System (ADS)

    Li, Z.; Che, W.; Frey, H. C.; Lau, A. K. H.

    2016-12-01

    Portable air monitors are currently being developed and used to enable a move towards exposure monitoring as opposed to fixed site monitoring. Reliable methods are needed regarding capturing spatial and temporal variability in exposure concentration to obtain credible data from which to develop efficient exposure mitigation measures. However, there are few studies that quantify the validity and repeatability of the collected data. The objective of this study is to present and evaluate a collocated exposure monitoring (CEM) methodology including the calibration of portable air monitors against stationary reference equipment, side-by-side comparison of portable air monitors, personal or microenvironmental exposure monitoring and the processing and interpretation of the collected data. The CEM methodology was evaluated based on application to portable monitors TSI DustTrak II Aerosol Monitor 8530 for fine particulate matter (PM2.5) and TSI Q-Trak model 7575 with probe model 982 for CO, CO2, temperature and relative humidity. Taking a school sampling campaign in Hong Kong in January and June, 2015 as an example, the calibrated side-by-side measured 1 Hz PM2.5 concentrations showed good consistency between two sets of portable air monitors. Confidence in side-by-side comparison, PM2.5 concentrations of which most of the time were within 2 percent, enabled robust inference regarding differences when the monitors measured in classroom and pedestrian during school hour. The proposed CEM methodology can be widely applied in sampling campaigns with the objective of simultaneously characterizing pollutant concentrations in two or more locations or microenvironments. The further application of the CEM methodology to transportation exposure will be presented and discussed.

  13. Development of advanced manufacturing technologies for low cost hydrogen storage vessels

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Leavitt, Mark; Lam, Patrick

    2014-12-29

    The U.S. Department of Energy (DOE) defined a need for low-cost gaseous hydrogen storage vessels at 700 bar to support cost goals aimed at 500,000 units per year. Existing filament winding processes produce a pressure vessel that is structurally inefficient, requiring more carbon fiber for manufacturing reasons, than would otherwise be necessary. Carbon fiber is the greatest cost driver in building a hydrogen pressure vessel. The objective of this project is to develop new methods for manufacturing Type IV pressure vessels for hydrogen storage with the purpose of lowering the overall product cost through an innovative hybrid process of optimizingmore » composite usage by combining traditional filament winding (FW) and advanced fiber placement (AFP) techniques. A numbers of vessels were manufactured in this project. The latest vessel design passed all the critical tests on the hybrid design per European Commission (EC) 79-2009 standard except the extreme temperature cycle test. The tests passed include burst test, cycle test, accelerated stress rupture test and drop test. It was discovered the location where AFP and FW overlap for load transfer could be weakened during hydraulic cycling at 85°C. To design a vessel that passed these tests, the in-house modeling software was updated to add capability to start and stop fiber layers to simulate the AFP process. The original in-house software was developed for filament winding only. Alternative fiber was also investigated in this project, but the added mass impacted the vessel cost negatively due to the lower performance from the alternative fiber. Overall the project was a success to show the hybrid design is a viable solution to reduce fiber usage, thus driving down the cost of fuel storage vessels. Based on DOE’s baseline vessel size of 147.3L and 91kg, the 129L vessel (scaled to DOE baseline) in this project shows a 32% composite savings and 20% cost savings when comparing Vessel 15 hybrid design and the Quantum

  14. Low-cost, light-switched, forward-osmosis desalination system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Warner, John C.

    The looming water crisis is the second largest issue facing humanity after energy. In order to meet the increasing demand for clean water, new efficient and low-cost methods of water purification must be developed. A promising method for dry regions with sea borders is the desalination of seawater. While there remain many disadvantages to current desalination techniques, such as environmental pollution and high cost, there is a strong opportunity for new technology development in this area. In this Phase I program, the development of a light-switchable, low-cost desalination system was explored. The system requires photoselective switching of water solubility. Ninemore » new light-switchable spiropyran-based small molecule and polymeric materials were synthesized, and methods to evaluate their desalination potential were developed and utilized. Severable promising spiropyran analogues proved to be photoswitchable, but so far sufficient photoswitchablity of solubility for a commercial desalination system was not achieved. More development is required.« less

  15. Design of a Novel Low Cost Point of Care Tampon (POCkeT) Colposcope for Use in Resource Limited Settings

    PubMed Central

    Lam, Christopher T.; Krieger, Marlee S.; Gallagher, Jennifer E.; Asma, Betsy; Muasher, Lisa C.; Schmitt, John W.; Ramanujam, Nimmi

    2015-01-01

    Introduction Current guidelines by WHO for cervical cancer screening in low- and middle-income countries involves visual inspection with acetic acid (VIA) of the cervix, followed by treatment during the same visit or a subsequent visit with cryotherapy if a suspicious lesion is found. Implementation of these guidelines is hampered by a lack of: trained health workers, reliable technology, and access to screening facilities. A low cost ultra-portable Point of Care Tampon based digital colposcope (POCkeT Colposcope) for use at the community level setting, which has the unique form factor of a tampon, can be inserted into the vagina to capture images of the cervix, which are on par with that of a state of the art colposcope, at a fraction of the cost. A repository of images to be compiled that can be used to empower front line workers to become more effective through virtual dynamic training. By task shifting to the community setting, this technology could potentially provide significantly greater cervical screening access to where the most vulnerable women live. The POCkeT Colposcope’s concentric LED ring provides comparable white and green field illumination at a fraction of the electrical power required in commercial colposcopes. Evaluation with standard optical imaging targets to assess the POCkeT Colposcope against the state of the art digital colposcope and other VIAM technologies. Results Our POCkeT Colposcope has comparable resolving power, color reproduction accuracy, minimal lens distortion, and illumination when compared to commercially available colposcopes. In vitro and pilot in vivo imaging results are promising with our POCkeT Colposcope capturing comparable quality images to commercial systems. Conclusion The POCkeT Colposcope is capable of capturing images suitable for cervical lesion analysis. Our portable low cost system could potentially increase access to cervical cancer screening in limited resource settings through task shifting to community

  16. Low-cost Solar Array (LSA) project

    NASA Technical Reports Server (NTRS)

    1978-01-01

    Progress made by the Low-Cost Silicon Solar Array Project during the period January through March 1978 is reported. It includes task reports on silicon material processing, large-area silicon sheet development, encapsulation materials testing and development, project engineering and operations, and manufacturing techniques, plus the steps taken to integrate these efforts.

  17. A portable fluorescence detector for fast ultra trace detection of explosive vapors

    NASA Astrophysics Data System (ADS)

    Xin, Yunhong; He, Gang; Wang, Qi; Fang, Yu

    2011-10-01

    This paper developed a portable detector based on a specific material-based fluorescent sensing film for an ultra trace detection of explosives, such as 2,4,6-trinitrotoluene (TNT) or its derivate 2,4-dinitrotoluene (DNT), in ambient air or on objects tainted by explosives. The fluorescent sensing films are based on single-layer chemistry and the signal amplification effect of conjugated polymers, which exhibited higher sensitivity and shorter response time to TNT or DNT at their vapor pressures. Due to application of the light emitting diode and the solid state photomultiplier and the cross-correlation-based circuit design technology, the device has the advantages of low-power, low-cost, small size, and an improved signal to noise ratio. The results of the experiments showed that the detector can real-time detect and identify of explosive vapors at extremely low levels; it is suitable for the identification of suspect luggage, forensic analyses, or battlefields clearing.

  18. A portable fluorescence detector for fast ultra trace detection of explosive vapors.

    PubMed

    Xin, Yunhong; He, Gang; Wang, Qi; Fang, Yu

    2011-10-01

    This paper developed a portable detector based on a specific material-based fluorescent sensing film for an ultra trace detection of explosives, such as 2,4,6-trinitrotoluene (TNT) or its derivate 2,4-dinitrotoluene (DNT), in ambient air or on objects tainted by explosives. The fluorescent sensing films are based on single-layer chemistry and the signal amplification effect of conjugated polymers, which exhibited higher sensitivity and shorter response time to TNT or DNT at their vapor pressures. Due to application of the light emitting diode and the solid state photomultiplier and the cross-correlation-based circuit design technology, the device has the advantages of low-power, low-cost, small size, and an improved signal to noise ratio. The results of the experiments showed that the detector can real-time detect and identify of explosive vapors at extremely low levels; it is suitable for the identification of suspect luggage, forensic analyses, or battlefields clearing.

  19. Implementation of a Portable Personal EKG Signal Monitoring System

    NASA Astrophysics Data System (ADS)

    Tan, Tan-Hsu; Chang, Ching-Su; Chen, Yung-Fu; Lee, Cheng

    This research develops a portable personal EKG signal monitoring system to help patients monitor their EKG signals instantly to avoid the occurrence of tragedies. This system is built with two main units: signal pro-cessing unit and monitoring and evaluation unit. The first unit consists of EKG signal sensor, signal amplifier, digitalization circuit, and related control circuits. The second unit is a software tool developed on an embedded Linux platform (called CSA). Experimental result indicates that the proposed system has the practical potential for users in health monitoring. It is demonstrated to be more convenient and with greater portability than the conventional PC-based EKG signal monitoring systems. Furthermore, all the application units embedded in the system are built with open source codes, no licensed fee is required for operating systems and authorized applications. Thus, the building cost is much lower than the traditional systems.

  20. Breath acetone monitoring by portable Si:WO3 gas sensors

    PubMed Central

    Righettoni, Marco; Tricoli, Antonio; Gass, Samuel; Schmid, Alex; Amann, Anton; Pratsinis, Sotiris E.

    2013-01-01

    Breath analysis has the potential for early stage detection and monitoring of illnesses to drastically reduce the corresponding medical diagnostic costs and improve the quality of life of patients suffering from chronic illnesses. In particular, the detection of acetone in the human breath is promising for non-invasive diagnosis and painless monitoring of diabetes (no finger pricking). Here, a portable acetone sensor consisting of flame-deposited and in situ annealed, Si-doped epsilon-WO3 nanostructured films was developed. The chamber volume was miniaturized while reaction-limited and transport-limited gas flow rates were identified and sensing temperatures were optimized resulting in a low detection limit of acetone (~20 ppb) with short response (10–15 s) and recovery times (35–70 s). Furthermore, the sensor signal (response) was robust against variations of the exhaled breath flow rate facilitating application of these sensors at realistic relative humidities (80–90%) as in the human breath. The acetone content in the breath of test persons was monitored continuously and compared to that of state-of-the-art proton transfer reaction mass spectrometry (PTR-MS). Such portable devices can accurately track breath acetone concentration to become an alternative to more elaborate breath analysis techniques. PMID:22790702

  1. A biodegradable colorimetric film for rapid low-cost field determination of formaldehyde contamination by digital image colorimetry.

    PubMed

    Wongniramaikul, Worawit; Limsakul, Wadcharawadee; Choodum, Aree

    2018-05-30

    A biodegradable colorimetric film was fabricated on the lid of portable tube for in-tube formaldehyde detection. Based on the entrapment of colorimetric reagents within a thin film of tapioca starch, the yellow reaction product was observed with formaldehyde. Intensity of the blue channel from the digital image of yellow product showed a linear relationship in the range of 0-25 mg L -1 with low detection limit of 0.7 ± 0.1 mg L -1 . Inter-day precision of 0.61-3.10%RSD were obtained with less than 4.2% relative error from control samples. The developed method was applied for various food samples in Phuket and formaldehyde concentration range was non-detectable to 1.413 mg kg -1 . The quantified concentrations of formaldehyde in fish and squid samples provided relative errors of -7.7% and +10.8% compared to spectrophotometry. This low cost sensor (∼0.04 USD/test) with digital image colorimetry was thus an effective alternative for formaldehyde detection in food sample. Copyright © 2018 Elsevier Ltd. All rights reserved.

  2. Development of Portable Venturi Kiln for Agricultural Waste Utilization by Carbonization Process

    NASA Astrophysics Data System (ADS)

    Agustina, S. E.; Chasanah, N.; Eris, A. P.

    2018-05-01

    Many types of kiln or carbonization equipment have been developed, but most of them were designed for big capacity and some also having low performance. This research aims to develop kiln, especially portable metal kiln, which has higher performance, more environmental- friendly, and can be used for several kinds of biomass or agricultural waste (not exclusive for one kind of biomass) as feeding material. To improve the kiln performance, a venturi drum type of portable kiln has been designed with an optimum capacity of 12.45 kg coconut shells. Basic idea of those design is heat flow improvement causing by venturi effect. The performance test for coconut shell carbonization shows that the carbonization process takes about 60-90 minutes to produce average yields of 23.8%., and the highest temperature of the process was 441 °C. The optimum performance has been achieved in the 4th test, which was producing 24% yield of highest charcoal quality (represented by LHV) in 65 minutes process at average temperature level 485 °C. For pecan shell and palm shell, design modification has been done by adding 6 air inlet holes and 3 ignition column to get better performance. While operation procedure should be modified on loading and air supply, depending on each biomass characteristic. The result of performance test showed that carbonization process of pecan shell produce 17 % yield, and palm shell produce 15% yield. Based on Indonesian Standard (SNI), all charcoal produced in those carbonization has good quality level.

  3. A Low-Cost Data Acquisition System for Automobile Dynamics Applications

    PubMed Central

    González, Alejandro; Vinolas, Jordi

    2018-01-01

    This project addresses the need for the implementation of low-cost acquisition technology in the field of vehicle engineering: the design, development, manufacture, and verification of a low-cost Arduino-based data acquisition platform to be used in <80 Hz data acquisition in vehicle dynamics, using low-cost accelerometers. In addition to this, a comparative study is carried out of professional vibration acquisition technologies and low-cost systems, obtaining optimum results for low- and medium-frequency operations with an error of 2.19% on road tests. It is therefore concluded that these technologies are applicable to the automobile industry, thereby allowing the project costs to be reduced and thus facilitating access to this kind of research that requires limited resources. PMID:29382039

  4. A Low-Cost Data Acquisition System for Automobile Dynamics Applications.

    PubMed

    González, Alejandro; Olazagoitia, José Luis; Vinolas, Jordi

    2018-01-27

    This project addresses the need for the implementation of low-cost acquisition technology in the field of vehicle engineering: the design, development, manufacture, and verification of a low-cost Arduino-based data acquisition platform to be used in <80 Hz data acquisition in vehicle dynamics, using low-cost accelerometers. In addition to this, a comparative study is carried out of professional vibration acquisition technologies and low-cost systems, obtaining optimum results for low- and medium-frequency operations with an error of 2.19% on road tests. It is therefore concluded that these technologies are applicable to the automobile industry, thereby allowing the project costs to be reduced and thus facilitating access to this kind of research that requires limited resources.

  5. Development of the silane process for the production of low-cost polysilicon

    NASA Technical Reports Server (NTRS)

    Iya, S. K.

    1986-01-01

    It was recognized that the traditional hot rod type deposition process for decomposing silane is energy intensive, and a different approach for converting silane to silicon was chosen. A 1200 metric tons/year capacity commercial plant was constructed in Moses Lake, Washington. A fluidized bed processor was chosen as the most promising technology and several encouraging test runs were conducted. This technology continues to be very promising in producing low cost polysilicon. The Union Carbide silane process and the research development on the fluidized bed silane decomposition are discussed.

  6. Development of ITM Oxygen Technology for Low-cost and Low-emission Gasification and Other Industrial Applications

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fogash, Kevin

    2015-12-15

    Air Products carried out a scope of work under DOE Award No. DE-FE0012065 “Development of ITM Oxygen Technology for Low-cost and Low-emission Gasification and Other Industrial Applications” with subcontractors Ceramatec, Penn State, and WorleyParsons. The scope of work under this award was aimed at furthering the development of the Ion Transport Membrane (ITM) Oxygen production process toward a demonstration-scale facility known as the Oxygen Development Facility (ODF). Specific activities will help to enable design and construction of the ODF through advancement of a number of challenging technical elements that are required to manage risk in the initial deployment of ITMmore » technology. Major objectives of the work included developing ITM Oxygen ceramic membrane materials with improved performance and reliability, optimizing ceramic module geometry and fabrication methods, testing module performance, trialing the improved fabrication process at commercial scale in the Ceramic Membrane Module Fabrication Facility (CerFab), and advancing engineering development of the ITM oxygen production process, including vessel design and contaminant control measures to prepare for deployment of the ODF. The comprehensive report that follows details the team’s work, which includes several notable accomplishments: 1) compressive creep, a likely limiter of ceramic module lifetime in service, was demonstrated to be retarded by an order of magnitude by changes in material formulation, module joining dimensions, and internal wafer geometry; 2) two promising new materials were shown to be superior to the incumbent ITM material in a key material parameter related to oxygen flux; 3) module degradation mechanisms were identified following operation in large pilot-scale equipment; 4) options for utilizing ITM in a coal-to-liquids (CTL) facility to enable liquids production with carbon capture were identified and studied; and 5) the benefits of potential improvements to the

  7. Development of ITM Oxygen Technology for Low-cost and Low-emission Gasification and Other Industrial Applications

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fogash, Kevin

    Air Products carried out a scope of work under DOE Award No. DE-FE0012065 “Development of ITM Oxygen Technology for Low-cost and Low-emission Gasification and Other Industrial Applications” with subcontractors Ceramatec, Penn State, and WorleyParsons. The scope of work under this award was aimed at furthering the development of the Ion Transport Membrane (ITM) Oxygen production process toward a demonstration-scale facility known as the Oxygen Development Facility (ODF). Specific activities will help to enable design and construction of the ODF through advancement of a number of challenging technical elements that are required to manage risk in the initial deployment of ITMmore » technology. Major objectives of the work included developing ITM Oxygen ceramic membrane materials with improved performance and reliability, optimizing ceramic module geometry and fabrication methods, testing module performance, trialing the improved fabrication process at commercial scale in the Ceramic Membrane Module Fabrication Facility (CerFab), and advancing engineering development of the ITM oxygen production process, including vessel design and contaminant control measures to prepare for deployment of the ODF. The comprehensive report that follows details the team’s work, which includes several notable accomplishments: 1) compressive creep, a likely limiter of ceramic module lifetime in service, was demonstrated to be retarded by an order of magnitude by changes in material formulation, module joining dimensions, and internal wafer geometry; 2) two promising new materials were shown to be superior to the incumbent ITM material in a key material parameter related to oxygen flux; 3) module degradation mechanisms were identified following operation in large pilot-scale equipment; 4) options for utilizing ITM in a coal-to-liquids (CTL) facility to enable liquids production with carbon capture were identified and studied; and 5) the benefits of potential improvements to the

  8. Evaluation of Energy Efficiency Improvements to Portable Classrooms in Florida.

    ERIC Educational Resources Information Center

    Callahan, Michael P.; Parker, Danny S.; Sherwin, John R.; Anello, Michael T.

    Findings are presented from a 2-year experiment exploring ways to reduce energy costs and improve the learning environment in Florida's 25,000 portable classrooms. Improvements were made in two highly instrumented portable classrooms in the following areas: installation of a T8 lighting system with electronic ballasts; a high efficiency heat pump…

  9. Development of low-cost meteorological observation system based on wireless network for poor-visibility occurred by snowstorm

    NASA Astrophysics Data System (ADS)

    Kobayashi, Y.; Watanabe, K.; Imai, M.; Watanabe, K.; Naruse, N.; Takahashi, Y.

    2016-12-01

    Hyper-densely monitoring for poor-visibility occurred by snowstorm is needed to make an alert system, because the snowstorm is difficult to predict from the observation only at a representative point. There are some problems in the previous approaches for the poor-visibility monitoring using video analyses or visibility meters; these require a wired network monitoring (a large amount of data: 10MB/sec at least) and the system cost is high (10,000 at each point). Thus, the risk of poor-visibility has been mainly measured at specific point such as airport and mountain pass, and estimated by simulation two dimensionally. To predict it two dimensionally and accurately, we have developed a low-cost meteorological system to observe the snowstorm hyper-densely. We have developed a low-cost visibility meter which works as the reduced intensity of semiconducting laser light when snow particles block off. Our developed system also has a capability of extending a hyper-densely observation in real-time on wireless network using Zigbee; A/D conversion and wireless data sent from temperature and illuminance sensors. We use a semiconducting laser chip (5) for the light source and a reflection mechanism by the use of three mirrors so as to send the light to a non-sensitive illuminance sensor directly. Thus, our visibility detecting system ($500) becomes much cheaper than previous one. We have checked the correlation between the reduced intensity taken by our system and the visibility recorded by conventional video camera. The value for the correlation coefficient was -0.67, which indicates a strong correlation. It means that our developed system is practical. In conclusion, we have developed low-cost meteorological detecting system to observe poor-visibility occurred by snowstorm, having a potential of hyper-densely monitoring on wireless network, and have made sure the practicability.

  10. Novel Structured Metal Bipolar Plates for Low Cost Manufacturing

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, Conghua

    Bipolar plates are an important component in fuel cell stacks and accounts for more than 75% of stack weight and volume, and 20% of the stack cost. The technology development of metal bipolar plates can effectively reduce the fuel cells stack weight and volume over 50%. The challenge is to protect metal plate from corrosion at low cost for the broad commercial applications. While most of today’s PEM fuel cell metallic bipolar plate technologies use some precious metal, the focus of this SBIR project is to develop a low cost, novel nano-structured metal bipolar plate coating technology without using anymore » precious metal. The technology must meet the performance and cost requirements for automobile applications.« less

  11. Ultraviolet Imaging with Low Cost Smartphone Sensors: Development and Application of a Raspberry Pi-Based UV Camera.

    PubMed

    Wilkes, Thomas C; McGonigle, Andrew J S; Pering, Tom D; Taggart, Angus J; White, Benjamin S; Bryant, Robert G; Willmott, Jon R

    2016-10-06

    Here, we report, for what we believe to be the first time, on the modification of a low cost sensor, designed for the smartphone camera market, to develop an ultraviolet (UV) camera system. This was achieved via adaptation of Raspberry Pi cameras, which are based on back-illuminated complementary metal-oxide semiconductor (CMOS) sensors, and we demonstrated the utility of these devices for applications at wavelengths as low as 310 nm, by remotely sensing power station smokestack emissions in this spectral region. Given the very low cost of these units, ≈ USD 25, they are suitable for widespread proliferation in a variety of UV imaging applications, e.g., in atmospheric science, volcanology, forensics and surface smoothness measurements.

  12. Ultraviolet Imaging with Low Cost Smartphone Sensors: Development and Application of a Raspberry Pi-Based UV Camera

    PubMed Central

    Wilkes, Thomas C.; McGonigle, Andrew J. S.; Pering, Tom D.; Taggart, Angus J.; White, Benjamin S.; Bryant, Robert G.; Willmott, Jon R.

    2016-01-01

    Here, we report, for what we believe to be the first time, on the modification of a low cost sensor, designed for the smartphone camera market, to develop an ultraviolet (UV) camera system. This was achieved via adaptation of Raspberry Pi cameras, which are based on back-illuminated complementary metal-oxide semiconductor (CMOS) sensors, and we demonstrated the utility of these devices for applications at wavelengths as low as 310 nm, by remotely sensing power station smokestack emissions in this spectral region. Given the very low cost of these units, ≈ USD 25, they are suitable for widespread proliferation in a variety of UV imaging applications, e.g., in atmospheric science, volcanology, forensics and surface smoothness measurements. PMID:27782054

  13. Low-cost flywheel demonstration program

    NASA Astrophysics Data System (ADS)

    Rabenhorst, D. W.; Small, T. R.; Wilkinson, W. O.

    1980-04-01

    All primary objectives were successfully achieved as follows: demonstration of a full-size, 1 kWh flywheel having an estimated cost in large-volume production of approximately $50/kWh; development of a ball-bearing system having losses comparable to the losses in a totally magnetic suspension system; successful and repeated demonstration of the low-cost flywheel in a complete flywheel energy-storage system based on the use of ordinary house voltage and frequency; and application of the experience gained in the hardware program to project the system design into a complete, full-scale, 30 kWh home-type flywheel energy-storage system.

  14. Development and programming of Geophonino: A low cost Arduino-based seismic recorder for vertical geophones

    NASA Astrophysics Data System (ADS)

    Soler-Llorens, J. L.; Galiana-Merino, J. J.; Giner-Caturla, J.; Jauregui-Eslava, P.; Rosa-Cintas, S.; Rosa-Herranz, J.

    2016-09-01

    The commercial data acquisition systems used for seismic exploration are usually expensive equipment. In this work, a low cost data acquisition system (Geophonino) has been developed for recording seismic signals from a vertical geophone. The signal goes first through an instrumentation amplifier, INA155, which is suitable for low amplitude signals like the seismic noise, and an anti-aliasing filter based on the MAX7404 switched-capacitor filter. After that, the amplified and filtered signal is digitized and processed by Arduino Due and registered in an SD memory card. Geophonino is configured for continuous registering, where the sampling frequency, the amplitude gain and the registering time are user-defined. The complete prototype is an open source and open hardware system. It has been tested by comparing the registered signals with the ones obtained through different commercial data recording systems and different kind of geophones. The obtained results show good correlation between the tested measurements, presenting Geophonino as a low-cost alternative system for seismic data recording.

  15. Low-cost, smartphone based frequency doubling technology visual field testing using virtual reality (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Alawa, Karam A.; Sayed, Mohamed; Arboleda, Alejandro; Durkee, Heather A.; Aguilar, Mariela C.; Lee, Richard K.

    2017-02-01

    Glaucoma is the leading cause of irreversible blindness worldwide. Due to its wide prevalence, effective screening tools are necessary. The purpose of this project is to design and evaluate a system that enables portable, cost effective, smartphone based visual field screening based on frequency doubling technology. The system is comprised of an Android smartphone to display frequency doubling stimuli and handle processing, a Bluetooth remote for user input, and a virtual reality headset to simulate the exam. The LG Nexus 5 smartphone and BoboVR Z3 virtual reality headset were used for their screen size and lens configuration, respectively. The system is capable of running the C-20, N-30, 24-2, and 30-2 testing patterns. Unlike the existing system, the smartphone FDT tests both eyes concurrently by showing the same background to both eyes but only displaying the stimulus to one eye at a time. Both the Humphrey Zeiss FDT and the smartphone FDT were tested on five subjects without a history of ocular disease with the C-20 testing pattern. The smartphone FDT successfully produced frequency doubling stimuli at the correct spatial and temporal frequency. Subjects could not tell which eye was being tested. All five subjects preferred the smartphone FDT to the Humphrey Zeiss FDT due to comfort and ease of use. The smartphone FDT is a low-cost, portable visual field screening device that can be used as a screening tool for glaucoma.

  16. 76 FR 44036 - Proposed Low-Effect Habitat Conservation Plan for the California Tiger Salamander, AT&T Portable...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-07-22

    ...] Proposed Low-Effect Habitat Conservation Plan for the California Tiger Salamander, AT&T Portable Generator... Federally listed animal, the California tiger salamander. The applicant would implement a conservation... permanently convert 1.24 acres of upland grassland habitat for the California tiger salamander into a new...

  17. Benefits and costs of low thrust propulsion systems

    NASA Technical Reports Server (NTRS)

    Robertson, R. I.; Rose, L. J.; Maloy, J. E.

    1983-01-01

    The results of costs/benefits analyses of three chemical propulsion systems that are candidates for transferring high density, low volume STS payloads from LEO to GEO are reported. Separate algorithms were developed for benefits and costs of primary propulsion systems (PPS) as functions of the required thrust levels. The life cycle costs of each system were computed based on the developmental, production, and deployment costs. A weighted criteria rating approach was taken for the benefits, with each benefit assigned a value commensurate to its relative worth to the overall system. Support costs were included in the costs modeling. Reference missions from NASA, commercial, and DoD catalog payloads were examined. The program was concluded reliable and flexible for evaluating benefits and costs of launch and orbit transfer for any catalog mission, with the most beneficial PPS being a dedicated low thrust configuration using the RL-10 system.

  18. Portable Radiation Detectors

    NASA Technical Reports Server (NTRS)

    1997-01-01

    Through a Small Business Innovation Research (SBIR) contract from Kennedy Space Center, General Pneumatics Corporation's Western Research Center satisfied a NASA need for a non-clogging Joule-Thomson cryostat to provide very low temperature cooling for various sensors. This NASA-supported cryostat development played a key part in the development of more portable high-purity geranium gamma-ray detectors. Such are necessary to discern between the radionuclides in medical, fuel, weapon, and waste materials. The outcome of the SBIR project is a cryostat that can cool gamma-ray detectors, without vibration, using compressed gas that can be stored compactly and indefinitely in a standby mode. General Pneumatics also produces custom J-T cryostats for other government, commercial and medical applications.

  19. Portable recording in the assessment of obstructive sleep apnea. ASDA standards of practice.

    PubMed

    Ferber, R; Millman, R; Coppola, M; Fleetham, J; Murray, C F; Iber, C; McCall, V; Nino-Murcia, G; Pressman, M; Sanders, M

    1994-06-01

    The objective assessment of patients with a presumptive diagnosis of obstructive sleep apnea (OSA) has primarily used attended polysomnographic study. Recent technologic advances and issues of availability, convenience and cost have led to a rapid increase in the use of portable recording devices. However, limited scientific information has been published regarding the evaluation of the efficacy, accuracy, validity, utility, cost effectiveness and limitations of this portable equipment. Attaining a clear assessment of the role of portable devices is complicated by the multiplicity of recording systems and the variability of clinical settings in which they have been analyzed. This paper reviews the current knowledge base regarding portable recording in the assessment of OSA, including technical considerations, validation studies, potential advantages and disadvantages, issues of safety, current clinical usage and areas most in need of further study.

  20. State-of-the-art low-cost solar reflector materials

    NASA Astrophysics Data System (ADS)

    Kennedy, C.; Jorgensen, G.

    1994-11-01

    Solar thermal technologies generate power by concentrating sunlight with large mirrors. The National Renewable Energy Laboratory (NREL) is working with industrial partners to develop the optical reflector materials needed for the successful deployment of this technology. The reflector materials must be low in cost and maintain high specular reflectance for extended lifetimes in severe outdoor environments. Currently, the best candidate materials for solar mirrors are silver-coated low-iron glass and silvered polymer films. Polymer reflectors are lighter in weight, offer greater flexibility in system design, and have the potential for lower cost than glass mirrors. In parallel with collaborative activities, several innovative candidate reflector-material constructions were investigated at NREL. The low-cost material requirement necessitates manufacturing compatible with mass-production techniques. Future cooperative efforts with the web-coating industry offers the promise of exciting new alternative materials and the potential for dramatic cost savings in developing advanced solar reflector materials.

  1. Automated array assembly task development of low-cost polysilicon solar cells

    NASA Technical Reports Server (NTRS)

    Jones, G. T.

    1980-01-01

    Development of low cost, large area polysilicon solar cells was conducted in this program. Three types of polysilicon materialk were investigated. A theoretical and experimenal comparison between single crystal silicon and polysilicon solar cell efficiency was performed. Significant electrical performance differences were observed between types of wafer material, i.e. fine grain and coarse grain polysilicon and single crystal silicon. Efficiency degradation due to grain boundaries in fin grain and coarse grain polysilicon was shown to be small. It was demonstrated that 10 percent efficient polysilicon solar cells can be produced with spray on n+ dopants. This result fulfills an important goal of this project, which is the production of batch quantity of 10 percent efficient polysilicon solar cells.

  2. Development of a Portable Taste Sensor with a Lipid/Polymer Membrane

    PubMed Central

    Tahara, Yusuke; Nakashi, Kenichi; Ji, Ke; Ikeda, Akihiro; Toko, Kiyoshi

    2013-01-01

    We have developed a new portable taste sensor with a lipid/polymer membrane and conducted experiments to evaluate the sensor's performance. The fabricated sensor consists of a taste sensor chip (40 mm × 26 mm × 2.2 mm) with working and reference electrodes and a portable sensor device (80 mm × 25 mm × 20 mm). The working electrode consists of a taste-sensing site comprising a poly(hydroxyethyl)methacrylate (pHEMA) hydrogel layer with KCl as the electrolyte layer and a lipid/polymer membrane as the taste sensing element. The reference electrode comprises a polyvinyl chloride (PVC) membrane layer with a small hole and a pHEMA layer with KCl. The whole device is the size of a USB memory stick, making it suitable for portable use. The sensor's response to tannic acid as the standard astringency substance showed good accuracy and reproducibility, and was comparable with the performance of a commercially available taste sensing system. Thus, it is possible for this sensor to be used for in-field evaluations and it can make a significant contribution to the food industry, as well as in various fields of research. PMID:23325168

  3. Transmutation of Personal Glucose Meters into Portable and Highly Sensitive Microbial Pathogen Detection Platform.

    PubMed

    Wang, Zhenzhen; Chen, Zhaowei; Gao, Nan; Ren, Jinsong; Qu, Xiaogang

    2015-10-07

    Herein, for the first time, we presented a simple and general approach by using personal glucose meters (PGM) for portable and ultrasensitive detection of microbial pathogens. Upon addition of pathogenic bacteria, glucoamylase-quaternized magnetic nanoparticles (GA-QMNPS) conjugates were disrupted by the competitive multivalent interactions between bacteria and QMNPS, resulting in the release of GA. After magnetic separation, the free GA could catalyze the hydrolysis of amylose into glucose for quantitative readout by PGM. In such way, PGM was transmuted into a bacterial detection device and extremely low detection limits down to 20 cells mL(-1) was achieved. More importantly, QMNPS could inhibit the growth of the bacteria and destroy its cellular structure, which enabled bacteria detection and inhibition simultaneously. The simplicity, portability, sensitivity and low cost of presented work make it attractive for clinical applications. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  4. Battery-operated, portable, and flexible air microplasma generation device for fabrication of microfluidic paper-based analytical devices on demand.

    PubMed

    Kao, Peng-Kai; Hsu, Cheng-Che

    2014-09-02

    A portable microplasma generation device (MGD) operated in ambient air is introduced for making a microfluidic paper-based analytical device (μPAD) that serves as a primary healthcare platform. By utilizing a printed circuit board fabrication process, a flexible and lightweight MGD can be fabricated within 30 min with ultra low-cost. This MGD can be driven by a portable power supply (less than two pounds), which can be powered using 12 V-batteries or ac-dc converters. This MGD is used to perform maskless patterning of hydrophilic patterns with sub-millimeter spatial resolution on hydrophobic paper substrates with good pattern transfer fidelity. Using this MGD to fabricate μPADs is demonstrated. With a proper design of the MGD electrode geometry, μPADs with 500-μm-wide flow channels can be fabricated within 1 min and with a cost of less than $USD 0.05/device. We then test the μPADs by performing quantitative colorimetric assay tests and establish a calibration curve for detection of glucose and nitrite. The results show a linear response to a glucose assay for 1-50 mM and a nitrite assay for 0.1-5 mM. The low cost, miniaturized, and portable MGD can be used to fabricate μPADs on demand, which is suitable for in-field diagnostic tests. We believe this concept brings impact to the field of biomedical analysis, environmental monitoring, and food safety survey.

  5. Temperature and Humidity Calibration of a Low-Cost Wireless Dust Sensor for Real-Time Monitoring.

    PubMed

    Hojaiji, Hannaneh; Kalantarian, Haik; Bui, Alex A T; King, Christine E; Sarrafzadeh, Majid

    2017-03-01

    This paper introduces the design, calibration, and validation of a low-cost portable sensor for the real-time measurement of dust particles within the environment. The proposed design consists of low hardware cost and calibration based on temperature and humidity sensing to achieve accurate processing of airborne dust density. Using commercial particulate matter sensors, a highly accurate air quality monitoring sensor was designed and calibrated using real world variations in humidity and temperature for indoor and outdoor applications. Furthermore, to provide a low-cost secure solution for real-time data transfer and monitoring, an onboard Bluetooth module with AES data encryption protocol was implemented. The wireless sensor was tested against a Dylos DC1100 Pro Air Quality Monitor, as well as an Alphasense OPC-N2 optical air quality monitoring sensor for accuracy. The sensor was also tested for reliability by comparing the sensor to an exact copy of itself under indoor and outdoor conditions. It was found that accurate measurements under real-world humid and temperature varying and dynamically changing conditions were achievable using the proposed sensor when compared to the commercially available sensors. In addition to accurate and reliable sensing, this sensor was designed to be wearable and perform real-time data collection and transmission, making it easy to collect and analyze data for air quality monitoring and real-time feedback in remote health monitoring applications. Thus, the proposed device achieves high quality measurements at lower-cost solutions than commercially available wireless sensors for air quality.

  6. LCX: Proposal for a low-cost commercial transport

    NASA Technical Reports Server (NTRS)

    Hartman, Troy; Hayatdavoudi, Maziar; Hettinga, Joel; Hooper, Matt; Nguyen, Phong

    1994-01-01

    The LCX has been developed in response to a request for proposal for an aircraft with 153 passenger capacity and a range of 3000 nautical miles. The goals of the LCX are to provide an aircraft which will achieve the stated mission requirements at the lowest cost possible, both for the manufacturer and the operator. Low cost in this request is defined as short and long term profitability. To achieve this objective, modern technologies attributing to low-cost operation without greatly increasing the cost of manufacturing were employed. These technologies include hybrid laminar flow control and the use of developing new manufacturing processes and philosophies. The LCX will provide a competitive alternative to the use of the Airbus A319/320/321 and the Boeing 737 series of aircraft. The LCX has a maximum weight of 150,000 lb. carried by a wing of 1140 ft(exp 2) and an aspect ratio of 10. The selling price of the LCX is 31 million in 1994 US dollars.

  7. Portable tongue-supported human computer interaction system design and implementation.

    PubMed

    Quain, Rohan; Khan, Masood Mehmood

    2014-01-01

    Tongue supported human-computer interaction (TSHCI) systems can help critically ill patients interact with both computers and people. These systems can be particularly useful for patients suffering injuries above C7 on their spinal vertebrae. Despite recent successes in their application, several limitations restrict performance of existing TSHCI systems and discourage their use in real life situations. This paper proposes a low-cost, less-intrusive, portable and easy to use design for implementing a TSHCI system. Two applications of the proposed system are reported. Design considerations and performance of the proposed system are also presented.

  8. Distributed processing for features improvement in real-time portable medical devices.

    PubMed

    Mercado, Erwin John Saavedra

    2008-01-01

    Portable biomedical devices are being developed and incorporated in daily life. Nevertheless, their standalone capacity is diminished due to the lack of processing power required to face such duties as for example, signal artifacts robustness in EKG monitor devices. The following paper presents a multiprocessor architecture made from simple microcontrollers to provide an increase in processing performance, power consumption efficiency and lower cost.

  9. VideoBeam portable laser communicator

    NASA Astrophysics Data System (ADS)

    Mecherle, G. Stephen; Holcomb, Terry L.

    1999-01-01

    A VideoBeamTM portable laser communicator has been developed which provides full duplex communication links consisting of high quality analog video and stereo audio. The 3.2-pound unit resembles a binocular-type form factor and has an operational range of over two miles (clear air) with excellent jam-resistance and low probability of interception characteristics. The VideoBeamTM unit is ideally suited for numerous military scenarios, surveillance/espionage, industrial precious mineral exploration, and campus video teleconferencing applications.

  10. Low Cost Airline Service Revolution

    DOT National Transportation Integrated Search

    1996-04-01

    This study concentrates on new entry by airlines with low cost operating : strategies. Low cost strategies have been the most successful in competing : with network carriers whose very size confers certain competitive advantages. : The purposes of th...

  11. Market survey of fuel cells in Mexico: Niche for low power portable systems

    NASA Astrophysics Data System (ADS)

    Ramírez-Salgado, Joel; Domínguez-Aguilar, Marco A.

    This work provides an overview of the potential market in Mexico for portable electronic devices to be potentially powered by direct methanol fuel cells. An extrapolation method based on data published in Mexico and abroad served to complete this market survey. A review of electronics consumption set the basis for the future forecast and technology assimilation. The potential market for fuel cells for mobile phones in Mexico will be around 5.5 billion USD by 2013, considering a cost of 41 USD per cell in a market of 135 million mobile phones. Likewise, the market for notebook computers, PDAs and other electronic devices will likely grow in the future, with a combined consumption of fuel cell technology equivalent to 1.6 billion USD by 2014.

  12. Low-cost space flight for attached payloads

    NASA Astrophysics Data System (ADS)

    Perkins, Frederick W.

    1991-07-01

    An important addition to the emerging commercial space sector is Standard Space Platforms Corporation's comprehensive low-cost flight service delivery system for small and developmental payloads. Standard provides a privately funded, proprietary, value-added transportation service which dramatically reduces cost and program duration for compliant payloads. It also provides a business-to-business service which is compatible with business investment decision timing and technology development cycles.

  13. Portable Parallel Programming for the Dynamic Load Balancing of Unstructured Grid Applications

    NASA Technical Reports Server (NTRS)

    Biswas, Rupak; Das, Sajal K.; Harvey, Daniel; Oliker, Leonid

    1999-01-01

    The ability to dynamically adapt an unstructured -rid (or mesh) is a powerful tool for solving computational problems with evolving physical features; however, an efficient parallel implementation is rather difficult, particularly from the view point of portability on various multiprocessor platforms We address this problem by developing PLUM, tin automatic anti architecture-independent framework for adaptive numerical computations in a message-passing environment. Portability is demonstrated by comparing performance on an SP2, an Origin2000, and a T3E, without any code modifications. We also present a general-purpose load balancer that utilizes symmetric broadcast networks (SBN) as the underlying communication pattern, with a goal to providing a global view of system loads across processors. Experiments on, an SP2 and an Origin2000 demonstrate the portability of our approach which achieves superb load balance at the cost of minimal extra overhead.

  14. Ultra-low current biosensor output detection using portable electronic reader

    NASA Astrophysics Data System (ADS)

    Yahaya, N. A. N.; Rajapaksha, R. D. A. A.; Uda, M. N. Afnan; Hashim, U.

    2017-09-01

    Generally, the electrical biosensor usually shows extremely low current signal output around pico ampere to microampere range. In this research, electronic reader with amplifier has been demonstrated to detect ultra low current via the biosensor. The operational amplifier Burr-Brown OPA 128 and Arduino Uno board were used to construct the portable electronic reader. There are two cascaded inverting amplifier were used to detect ultra low current through the biosensor from pico amperes (pA) to nano amperes ranges (nA). A small known input current was form by applying variable voltage between 0.1V to 5.0V across a 5GΩ high resistor to check the amplifier circuit. The amplifier operation was measured with the high impedance current source and has been compared with the theoretical measurement. The Arduino Uno was used to convert the analog signal to digital signal and process the data to display on reader screen. In this project, Proteus software was used to design and test the circuit. Then it was implemented together with Arduino Uno board. Arduino board was programmed using C programming language to make whole circuit communicate each order. The current was measured then it shows a small difference values compared to theoretical values, which is approximately 14pA.

  15. Development of a Portable Torque Wrench Tester

    NASA Astrophysics Data System (ADS)

    Wang, Y.; Zhang, Q.; Gou, C.; Su, D.

    2018-03-01

    A portable torque wrench tester (PTWT) with calibration range from 0.5 Nm to 60 Nm has been developed and evaluated for periodic or on-site calibration of setting type torque wrenches, indicating type torque wrenches and hand torque screwdrivers. The PTWT is easy to carry with weight about 10 kg, simple and efficient operation and energy saving with an automatic loading and calibrating system. The relative expanded uncertainty of torque realized by the PTWT was estimated to be 0.8%, with the coverage factor k=2. A comparison experiment has been done between the PTWT and a reference torque standard at our laboratory. The consistency between these two devices under the claimed uncertainties was verified.

  16. Low cost damage tolerant composite fabrication

    NASA Technical Reports Server (NTRS)

    Palmer, R. J.; Freeman, W. T.

    1988-01-01

    The resin transfer molding (RTM) process applied to composite aircraft parts offers the potential for using low cost resin systems with dry graphite fabrics that can be significantly less expensive than prepreg tape fabricated components. Stitched graphite fabric composites have demonstrated compression after impact failure performance that equals or exceeds that of thermoplastic or tough thermoset matrix composites. This paper reviews methods developed to fabricate complex shape composite parts using stitched graphite fabrics to increase damage tolerance with RTM processes to reduce fabrication cost.

  17. PubMedPortable: A Framework for Supporting the Development of Text Mining Applications.

    PubMed

    Döring, Kersten; Grüning, Björn A; Telukunta, Kiran K; Thomas, Philippe; Günther, Stefan

    2016-01-01

    Information extraction from biomedical literature is continuously growing in scope and importance. Many tools exist that perform named entity recognition, e.g. of proteins, chemical compounds, and diseases. Furthermore, several approaches deal with the extraction of relations between identified entities. The BioCreative community supports these developments with yearly open challenges, which led to a standardised XML text annotation format called BioC. PubMed provides access to the largest open biomedical literature repository, but there is no unified way of connecting its data to natural language processing tools. Therefore, an appropriate data environment is needed as a basis to combine different software solutions and to develop customised text mining applications. PubMedPortable builds a relational database and a full text index on PubMed citations. It can be applied either to the complete PubMed data set or an arbitrary subset of downloaded PubMed XML files. The software provides the infrastructure to combine stand-alone applications by exporting different data formats, e.g. BioC. The presented workflows show how to use PubMedPortable to retrieve, store, and analyse a disease-specific data set. The provided use cases are well documented in the PubMedPortable wiki. The open-source software library is small, easy to use, and scalable to the user's system requirements. It is freely available for Linux on the web at https://github.com/KerstenDoering/PubMedPortable and for other operating systems as a virtual container. The approach was tested extensively and applied successfully in several projects.

  18. PubMedPortable: A Framework for Supporting the Development of Text Mining Applications

    PubMed Central

    Döring, Kersten; Grüning, Björn A.; Telukunta, Kiran K.; Thomas, Philippe; Günther, Stefan

    2016-01-01

    Information extraction from biomedical literature is continuously growing in scope and importance. Many tools exist that perform named entity recognition, e.g. of proteins, chemical compounds, and diseases. Furthermore, several approaches deal with the extraction of relations between identified entities. The BioCreative community supports these developments with yearly open challenges, which led to a standardised XML text annotation format called BioC. PubMed provides access to the largest open biomedical literature repository, but there is no unified way of connecting its data to natural language processing tools. Therefore, an appropriate data environment is needed as a basis to combine different software solutions and to develop customised text mining applications. PubMedPortable builds a relational database and a full text index on PubMed citations. It can be applied either to the complete PubMed data set or an arbitrary subset of downloaded PubMed XML files. The software provides the infrastructure to combine stand-alone applications by exporting different data formats, e.g. BioC. The presented workflows show how to use PubMedPortable to retrieve, store, and analyse a disease-specific data set. The provided use cases are well documented in the PubMedPortable wiki. The open-source software library is small, easy to use, and scalable to the user’s system requirements. It is freely available for Linux on the web at https://github.com/KerstenDoering/PubMedPortable and for other operating systems as a virtual container. The approach was tested extensively and applied successfully in several projects. PMID:27706202

  19. U.S. DOE Progress Towards Developing Low-Cost, High Performance, Durable Polymer Electrolyte Membranes for Fuel Cell Applications

    PubMed Central

    Houchins, Cassidy; Kleen, Greg J.; Spendelow, Jacob S.; Kopasz, John; Peterson, David; Garland, Nancy L.; Ho, Donna Lee; Marcinkoski, Jason; Martin, Kathi Epping; Tyler, Reginald; Papageorgopoulos, Dimitrios C.

    2012-01-01

    Low cost, durable, and selective membranes with high ionic conductivity are a priority need for wide-spread adoption of polymer electrolyte membrane fuel cells (PEMFCs) and direct methanol fuel cells (DMFCs). Electrolyte membranes are a major cost component of PEMFC stacks at low production volumes. PEMFC membranes also impose limitations on fuel cell system operating conditions that add system complexity and cost. Reactant gas and fuel permeation through the membrane leads to decreased fuel cell performance, loss of efficiency, and reduced durability in both PEMFCs and DMFCs. To address these challenges, the U.S. Department of Energy (DOE) Fuel Cell Technologies Program, in the Office of Energy Efficiency and Renewable Energy, supports research and development aimed at improving ion exchange membranes for fuel cells. For PEMFCs, efforts are primarily focused on developing materials for higher temperature operation (up to 120 °C) in automotive applications. For DMFCs, efforts are focused on developing membranes with reduced methanol permeability. In this paper, the recently revised DOE membrane targets, strategies, and highlights of DOE-funded projects to develop new, inexpensive membranes that have good performance in hot and dry conditions (PEMFC) and that reduce methanol crossover (DMFC) will be discussed. PMID:24958432

  20. U.S. DOE Progress Towards Developing Low-Cost, High Performance, Durable Polymer Electrolyte Membranes for Fuel Cell Applications.

    PubMed

    Houchins, Cassidy; Kleen, Greg J; Spendelow, Jacob S; Kopasz, John; Peterson, David; Garland, Nancy L; Ho, Donna Lee; Marcinkoski, Jason; Martin, Kathi Epping; Tyler, Reginald; Papageorgopoulos, Dimitrios C

    2012-12-18

    Low cost, durable, and selective membranes with high ionic conductivity are a priority need for wide-spread adoption of polymer electrolyte membrane fuel cells (PEMFCs) and direct methanol fuel cells (DMFCs). Electrolyte membranes are a major cost component of PEMFC stacks at low production volumes. PEMFC membranes also impose limitations on fuel cell system operating conditions that add system complexity and cost. Reactant gas and fuel permeation through the membrane leads to decreased fuel cell performance, loss of efficiency, and reduced durability in both PEMFCs and DMFCs. To address these challenges, the U.S. Department of Energy (DOE) Fuel Cell Technologies Program, in the Office of Energy Efficiency and Renewable Energy, supports research and development aimed at improving ion exchange membranes for fuel cells. For PEMFCs, efforts are primarily focused on developing materials for higher temperature operation (up to 120 °C) in automotive applications. For DMFCs, efforts are focused on developing membranes with reduced methanol permeability. In this paper, the recently revised DOE membrane targets, strategies, and highlights of DOE-funded projects to develop new, inexpensive membranes that have good performance in hot and dry conditions (PEMFC) and that reduce methanol crossover (DMFC) will be discussed.

  1. A Portable Computer System for Auditing Quality of Ambulatory Care

    PubMed Central

    McCoy, J. Michael; Dunn, Earl V.; Borgiel, Alexander E.

    1987-01-01

    Prior efforts to effectively and efficiently audit quality of ambulatory care based on comprehensive process criteria have been limited largely by the complexity and cost of data abstraction and management. Over the years, several demonstration projects have generated large sets of process criteria and mapping systems for evaluating quality of care, but these paper-based approaches have been impractical to implement on a routine basis. Recognizing that portable microcomputers could solve many of the technical problems in abstracting data from medical records, we built upon previously described criteria and developed a microcomputer-based abstracting system that facilitates reliable and cost-effective data abstraction.

  2. Study of CdTe/CdS solar cell at low power density for low-illumination applications

    NASA Astrophysics Data System (ADS)

    Devi, Nisha; Aziz, Anver; Datta, Shouvik

    2016-05-01

    In this paper, we numerically investigate CdTe/CdS PV cell properties using a simulation program Solar Cell Capacitance Simulator in 1D (SCAPS-1D). A simple structure of CdTe PV cell has been optimized to study the effect of temperature, absorber thickness and work function at very low incident power. Objective of this research paper is to build an efficient and cost effective solar cell for portable electronic devices such as portable computers and cell phones that work at low incident power because most of such devices work at diffused and reflected sunlight. In this report, we simulated a simple CdTe PV cell at very low incident power, which gives good efficiency.

  3. Laser machined plastic laminates. Towards portable diagnostic devices for use in low resource environments

    DOE PAGES

    Harper, Jason C.; Carson, Bryan D.; Bachand, George D.; ...

    2015-07-14

    Despite significant progress in development of bioanalytical devices cost, complexity, access to reagents and lack of infrastructure have prevented use of these technologies in resource-limited regions. To provide a sustainable tool in the global effort to combat infectious diseases the diagnostic device must be low cost, simple to operate and read, robust, and have sensitivity and specificity comparable to laboratory analysis. Thus, in this mini-review we describe recent work using laser machined plastic laminates to produce diagnostic devices that are capable of a wide variety of bioanalytical measurements and show great promise towards future use in low-resource environments.

  4. Fuel Processor Development for a Soldier-Portable Fuel Cell System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Palo, Daniel R.; Holladay, Jamie D.; Rozmiarek, Robert T.

    2002-01-01

    Battelle is currently developing a soldier-portable power system for the U.S. Army that will continuously provide 15 W (25 W peak) of base load electric power for weeks or months using a micro technology-based fuel processor. The fuel processing train consists of a combustor, two vaporizers, and a steam-reforming reactor. This paper describes the concept and experimental progress to date.

  5. Implementation of a low-cost mobile devices to support medical diagnosis.

    PubMed

    García Sánchez, Carlos; Botella Juan, Guillermo; Ayuso Márquez, Fermín; González Rodríguez, Diego; Prieto-Matías, Manuel; Tirado Fernández, Francisco

    2013-01-01

    Medical imaging has become an absolutely essential diagnostic tool for clinical practices; at present, pathologies can be detected with an earliness never before known. Its use has not only been relegated to the field of radiology but also, increasingly, to computer-based imaging processes prior to surgery. Motion analysis, in particular, plays an important role in analyzing activities or behaviors of live objects in medicine. This short paper presents several low-cost hardware implementation approaches for the new generation of tablets and/or smartphones for estimating motion compensation and segmentation in medical images. These systems have been optimized for breast cancer diagnosis using magnetic resonance imaging technology with several advantages over traditional X-ray mammography, for example, obtaining patient information during a short period. This paper also addresses the challenge of offering a medical tool that runs on widespread portable devices, both on tablets and/or smartphones to aid in patient diagnostics.

  6. Implementation of a Low-Cost Mobile Devices to Support Medical Diagnosis

    PubMed Central

    García Sánchez, Carlos; Botella Juan, Guillermo; Ayuso Márquez, Fermín; González Rodríguez, Diego; Prieto-Matías, Manuel; Tirado Fernández, Francisco

    2013-01-01

    Medical imaging has become an absolutely essential diagnostic tool for clinical practices; at present, pathologies can be detected with an earliness never before known. Its use has not only been relegated to the field of radiology but also, increasingly, to computer-based imaging processes prior to surgery. Motion analysis, in particular, plays an important role in analyzing activities or behaviors of live objects in medicine. This short paper presents several low-cost hardware implementation approaches for the new generation of tablets and/or smartphones for estimating motion compensation and segmentation in medical images. These systems have been optimized for breast cancer diagnosis using magnetic resonance imaging technology with several advantages over traditional X-ray mammography, for example, obtaining patient information during a short period. This paper also addresses the challenge of offering a medical tool that runs on widespread portable devices, both on tablets and/or smartphones to aid in patient diagnostics. PMID:24489600

  7. Development of an ultra-portable echo device connected to USB port.

    PubMed

    Saijo, Yoshifumi; Nitta, Shin-ichi; Kobayashi, Kazuto; Arai, Hitoshi; Nemoto, Yukiko

    2004-04-01

    In practical cardiology, a stethoscope based auscultation has been used to reveal the patient's clinical status. Recently, several hand-held echo devices are going on market and they are expected to play a role as "visible" auscultation instead of stethoscope. We have developed a portable and inexpensive echo device which can be used for screening of cardiac function. Two single element transducers were attached 180 degrees apart to a rotor with 14-mm diameter. The mechanical scanner, integrated circuits for transmitting and receiving ultrasonic signals and an A/D converter were encapsulated in a 150 x 40 mm probe weighing 200 g. The scan was started and the image was displayed on a Windows based personal computer (PC) as soon as the probe was connected to USB 2.0 port of the PC. The central frequency was available between 2.5 and 7.5 MHz, the image depth was 15 cm and the frame rate was 30/s. The estimated price of this ultra-portable ultrasound is about 3000 US dollars with software. For 69 cardiac patients with informed consent, image quality was compared with those obtained with basic range diagnostic echo machines. Left ventricular ejection fraction (EF) derived from normal M-mode image of standard machines (EFm) were compared with visual EF of the ultra-portable ultrasound device (EFv). The image quality was comparable to the basic range diagnostic echo machines although short axis view of aortic root was not clearly visualized because the probe was too large for intercostal approach. EFv agreed well with EFm. The ultra-portable ultrasound may provide useful information on screening and health care.

  8. Portable classroom leads to partnership.

    PubMed

    Le Ber, Jeanne Marie; Lombardo, Nancy T; Weber, Alice; Bramble, John

    2004-01-01

    Library faculty participation on the School of Medicine Curriculum Steering Committee led to a unique opportunity to partner technology and teaching utilizing the library's portable wireless classroom. The pathology lab course master expressed a desire to revise the curriculum using patient cases and direct access to the Web and library resources. Since the pathology lab lacked computers, the library's portable wireless classroom provided a solution. Originally developed to provide maximum portability and flexibility, the wireless classroom consists of ten laptop computers configured with wireless cards and an access point. While the portable wireless classroom led to a partnership with the School of Medicine, there were additional benefits and positive consequences for the library.

  9. Recent advances in microbial production of mannitol: utilization of low-cost substrates, strain development and regulation strategies.

    PubMed

    Zhang, Min; Gu, Lei; Cheng, Chao; Ma, Jiangfeng; Xin, Fengxue; Liu, Junli; Wu, Hao; Jiang, Min

    2018-02-26

    Mannitol has been widely used in fine chemicals, pharmaceutical industries, as well as functional foods due to its excellent characteristics, such as antioxidant protecting, regulation of osmotic pressure and non-metabolizable feature. Mannitol can be naturally produced by microorganisms. Compared with chemical manufacturing, microbial production of mannitol provides high yield and convenience in products separation; however the fermentative process has not been widely adopted yet. A major obstacle to microbial production of mannitol under industrial-scale lies in the low economical efficiency, owing to the high cost of fermentation medium, leakage of fructose, low mannitol productivity. In this review, recent advances in improving the economical efficiency of microbial production of mannitol were reviewed, including utilization of low-cost substrates, strain development for high mannitol yield and process regulation strategies for high productivity.

  10. Advanced Spacesuit Portable Life Support System Packaging Concept Mock-Up Design & Development

    NASA Technical Reports Server (NTRS)

    O''Connell, Mary K.; Slade, Howard G.; Stinson, Richard G.

    1998-01-01

    A concentrated development effort was begun at NASA Johnson Space Center to create an advanced Portable Life Support System (PLSS) packaging concept. Ease of maintenance, technological flexibility, low weight, and minimal volume are targeted in the design of future micro-gravity and planetary PLSS configurations. Three main design concepts emerged from conceptual design techniques and were carried forth into detailed design, then full scale mock-up creation. "Foam", "Motherboard", and "LEGOtm" packaging design concepts are described in detail. Results of the evaluation process targeted maintenance, robustness, mass properties, and flexibility as key aspects to a new PLSS packaging configuration. The various design tools used to evolve concepts into high fidelity mock ups revealed that no single tool was all encompassing, several combinations were complimentary, the devil is in the details, and, despite efforts, many lessons were learned only after working with hardware.

  11. Grading Multiple Choice Exams with Low-Cost and Portable Computer-Vision Techniques

    ERIC Educational Resources Information Center

    Fisteus, Jesus Arias; Pardo, Abelardo; García, Norberto Fernández

    2013-01-01

    Although technology for automatic grading of multiple choice exams has existed for several decades, it is not yet as widely available or affordable as it should be. The main reasons preventing this adoption are the cost and the complexity of the setup procedures. In this paper, "Eyegrade," a system for automatic grading of multiple…

  12. Developing a Low-Cost Force Treadmill via Dynamic Modeling.

    PubMed

    Hong, Chih-Yuan; Guo, Lan-Yuen; Song, Rong; Nagurka, Mark L; Sung, Jia-Li; Yen, Chen-Wen

    2017-01-01

    By incorporating force transducers into treadmills, force platform-instrumented treadmills (commonly called force treadmills) can collect large amounts of gait data and enable the ground reaction force (GRF) to be calculated. However, the high cost of force treadmills has limited their adoption. This paper proposes a low-cost force treadmill system with force sensors installed underneath a standard exercise treadmill. It identifies and compensates for the force transmission dynamics from the actual GRF applied on the treadmill track surface to the force transmitted to the force sensors underneath the treadmill body. This study also proposes a testing procedure to assess the GRF measurement accuracy of force treadmills. Using this procedure in estimating the GRF of "walk-on-the-spot motion," it was found that the total harmonic distortion of the tested force treadmill system was about 1.69%, demonstrating the effectiveness of the approach.

  13. A semi-automated, field-portable microscopy platform for clinical diagnostic applications

    NASA Astrophysics Data System (ADS)

    Jagannadh, Veerendra Kalyan; Srinivasan, Rajesh; Gorthi, Sai Siva

    2015-08-01

    Clinical microscopy is a versatile diagnostic platform used for diagnosis of a multitude of diseases. In the recent past, many microfluidics based point-of-care diagnostic devices have been developed, which serve as alternatives to microscopy. However, these point-of-care devices are not as multi-functional and versatile as clinical microscopy. With the use of custom designed optics and microfluidics, we have developed a versatile microscopy-based cellular diagnostic platform, which can be used at the point of care. The microscopy platform presented here is capable of detecting infections of very low parasitemia level (in a very small quantity of sample), without the use of any additional computational hardware. Such a cost-effective and portable diagnostic device, would greatly impact the quality of health care available to people living in rural locations of the world. Apart from clinical diagnostics, it's applicability to field research in environmental microbiology has also been outlined.

  14. Development and Applications of Portable Gas Chromatography-Mass Spectrometry for Emergency Responders, the Military, and Law-Enforcement Organizations.

    PubMed

    Leary, Pauline E; Dobson, Gareth S; Reffner, John A

    2016-05-01

    Portable gas chromatography-mass spectrometry (GC-MS) systems are being deployed for field use, and are designed with this goal in mind. Performance characteristics of instruments that are successful in the field are different from those of equivalent technologies that are successful in a laboratory setting. These field-portable systems are extending the capabilities of the field user, providing investigative leads and confirmatory identifications in real time. Many different types of users benefit from the availability of this technology including emergency responders, the military, and law-enforcement organizations. This manuscript describes performance characteristics that are important for field-portable instruments, especially field-portable GC-MS systems, and demonstrates the value of this equipment to the disciplines of explosives investigations, fire investigations, and counterfeit-drug detection. This paper describes the current state of portable GC-MS technology, including a review of the development of portable GC-MS, as well as a demonstration of the value of this capability using different examples. © The Author(s) 2016.

  15. Low Cost Carbon Fibre: Applications, Performance and Cost Models - Chapter 17

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Warren, Charles David; Wheatley, Dr. Alan; Das, Sujit

    2014-01-01

    Weight saving in automotive applications has a major bearing on fuel economy. It is generally accepted that, typically, a 10% weight reduction in an automobile will lead to a 6-8% improvement in fuel economy. In this respect, carbon fibre composites are extremely attractive in their ability to provide superlative mechanical performance per unit weight. That is why they are specified for high-end uses such as Formula 1 racing cars and the latest aircraft (e.g. Boeing 787, Airbus A350 and A380), where they comprise over 50% by weight of the structure However, carbon fibres are expensive and this renders their compositesmore » similarly expensive. Research has been carried out at Oak Ridge National Laboratories (ORNL), Tennessee, USA for over a decade with the aim of reducing the cost of carbon fibre such that it becomes a cost-effective option for the automotive industry. Aspects of this research relating to the development of low cost carbon fibre have been reported in Chapter 3 of this publication. In this chapter, the practical industrial applications of low-cost carbon fibre are presented, together with considerations of the performance and cost models which underpin the work.« less

  16. Low cost, high performance, self-aligning miniature optical systems

    PubMed Central

    Kester, Robert T.; Christenson, Todd; Kortum, Rebecca Richards; Tkaczyk, Tomasz S.

    2009-01-01

    The most expensive aspects in producing high quality miniature optical systems are the component costs and long assembly process. A new approach for fabricating these systems that reduces both aspects through the implementation of self-aligning LIGA (German acronym for lithographie, galvanoformung, abformung, or x-ray lithography, electroplating, and molding) optomechanics with high volume plastic injection molded and off-the-shelf glass optics is presented. This zero alignment strategy has been incorporated into a miniature high numerical aperture (NA = 1.0W) microscope objective for a fiber confocal reflectance microscope. Tight alignment tolerances of less than 10 μm are maintained for all components that reside inside of a small 9 gauge diameter hypodermic tubing. A prototype system has been tested using the slanted edge modulation transfer function technique and demonstrated to have a Strehl ratio of 0.71. This universal technology is now being developed for smaller, needle-sized imaging systems and other portable point-of-care diagnostic instruments. PMID:19543344

  17. Low-Cost SIRTF Flight Operations

    NASA Astrophysics Data System (ADS)

    Deutsch, M.-J.; Ebersole, M.; Nichols, J.

    1997-12-01

    The Space Infrared Telescope Facility (SIRTF) , the fourth of the Great Observatories, will be placed in a unique solar orbit trailing the Earth, in 2001. SIRTF will acquire both imaging and spectral data using large infrared detector arrays from 3.5mm to 160mm. The primary science objectives are (1) search for and study of brown dwarfs and super planets, (2) discovery and study of protoplanetary debris disks, (3) study of ultraluminous galaxies and active galactic nuclei, and (4) study of the early Universe. Driven by the limited cryogenic lifetime of 2.5 years, with a goal of 5 years, and the severely cost-capped development, a Mission Planning and Operations system is being designed that will result in high on-board efficiency (>90%) and low-cost operation, yet will accommodate rapid response science requirements . SIRTF is designing an architecture for an operations system that will be shared between science and flight operations. Crucial to this effort is the philosophy of an integrated science and engineering plan, co-location, cross-training of teams and common planning tools. The common tool set will enable the automatic generation of an integrated and conflict free planned schedule accommodating 20 000 observations and engineering activities a year. The shared tool set will help generate standard observations , (sometimes non-standard) engineering activities and manage the ground and flight resources and constraints appropriately. The ground software will allow the development from the ground of robust event driven sequences. Flexibility will be provided to incorporate newly discovered science opportunities or health issues late in the process and via quick links. This shared science and flight operations process if used from observation selection through sequence and command generation, will provide a low-cost operations system. Though SIRTF is a 'Great Observatory', its annual mission operations costs will more closely resemble those of an Explorer class

  18. Developing a Low-Cost System for 3d Data Acquisition

    NASA Astrophysics Data System (ADS)

    Kossieris, S.; Kourounioti, O.; Agrafiotis, P.; Georgopoulos, A.

    2017-11-01

    In this paper, a developed low-cost system is described, which aims to facilitate 3D documentation fast and reliably by acquiring the necessary data in outdoor environment for the 3D documentation of façades especially in the case of very narrow streets. In particular, it provides a viable solution for buildings up to 8-10m high and streets as narrow as 2m or even less. In cases like that, it is practically impossible or highly time-consuming to acquire images in a conventional way. This practice would lead to a huge number of images and long processing times. The developed system was tested in the narrow streets of a medieval village on the Greek island of Chios. There, in order to by-pass the problem of short taking distances, it was thought to use high definition action cameras together with a 360˚ camera, which are usually provided with very wide-angle lenses and are capable of acquiring images, of high definition, are rather cheap and, most importantly, extremely light. Results suggest that the system can perform fast 3D data acquisition adequate for deliverables of high quality.

  19. Portable parallel stochastic optimization for the design of aeropropulsion components

    NASA Technical Reports Server (NTRS)

    Sues, Robert H.; Rhodes, G. S.

    1994-01-01

    This report presents the results of Phase 1 research to develop a methodology for performing large-scale Multi-disciplinary Stochastic Optimization (MSO) for the design of aerospace systems ranging from aeropropulsion components to complete aircraft configurations. The current research recognizes that such design optimization problems are computationally expensive, and require the use of either massively parallel or multiple-processor computers. The methodology also recognizes that many operational and performance parameters are uncertain, and that uncertainty must be considered explicitly to achieve optimum performance and cost. The objective of this Phase 1 research was to initialize the development of an MSO methodology that is portable to a wide variety of hardware platforms, while achieving efficient, large-scale parallelism when multiple processors are available. The first effort in the project was a literature review of available computer hardware, as well as review of portable, parallel programming environments. The first effort was to implement the MSO methodology for a problem using the portable parallel programming language, Parallel Virtual Machine (PVM). The third and final effort was to demonstrate the example on a variety of computers, including a distributed-memory multiprocessor, a distributed-memory network of workstations, and a single-processor workstation. Results indicate the MSO methodology can be well-applied towards large-scale aerospace design problems. Nearly perfect linear speedup was demonstrated for computation of optimization sensitivity coefficients on both a 128-node distributed-memory multiprocessor (the Intel iPSC/860) and a network of workstations (speedups of almost 19 times achieved for 20 workstations). Very high parallel efficiencies (75 percent for 31 processors and 60 percent for 50 processors) were also achieved for computation of aerodynamic influence coefficients on the Intel. Finally, the multi-level parallelization

  20. Engineering the bioelectrochemical interface using functional nanomaterials and microchip technique toward sensitive and portable electrochemical biosensors.

    PubMed

    Jia, Xiaofang; Dong, Shaojun; Wang, Erkang

    2016-02-15

    Electrochemical biosensors have played active roles at the forefront of bioanalysis because they have the potential to achieve sensitive, specific and low-cost detection of biomolecules and many others. Engineering the electrochemical sensing interface with functional nanomaterials leads to novel electrochemical biosensors with improved performances in terms of sensitivity, selectivity, stability and simplicity. Functional nanomaterials possess good conductivity, catalytic activity, biocompatibility and high surface area. Coupled with bio-recognition elements, these features can amplify signal transduction and biorecognition events, resulting in highly sensitive biosensing. Additionally, microfluidic electrochemical biosensors have attracted considerable attention on account of their miniature, portable and low-cost systems as well as high fabrication throughput and ease of scaleup. For example, electrochemical enzymetic biosensors and aptamer biosensors (aptasensors) based on the integrated microchip can be used for portable point-of-care diagnostics and environmental monitoring. This review is a summary of our recent progress in the field of electrochemical biosensors, including aptasensors, cytosensors, enzymatic biosensors and self-powered biosensors based on biofuel cells. We presented the advantages that functional nanomaterials and microfluidic chip technology bring to the electrochemical biosensors, together with future prospects and possible challenges. Copyright © 2015 Elsevier B.V. All rights reserved.

  1. Low-cost, highly transparent flexible low-e coating film to enable electrochromic windows with increased energy savings

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Berland, Brian; Hollingsworth, Russell

    Five Quads of energy are lost through windows annually in the U.S. Low-e coatings are increasingly employed to reduce the wasted energy. Most commonly, the low-e coating is an oxide material applied directly to the glass at high temperature. With over 100,000,000 existing homes, a retrofit product is crucial to achieve widespread energy savings. Low-e films, i.e. coatings on polymeric substrates, are now also available to meet this need. However, the traditional oxide materials and process is incompatible with low temperature plastics. Alternate high performing low-e films typically incorporate materials that limit visible transmission to 35% or less. Further, themore » cost is high. The objective of this award was to develop a retrofit, integrated low-e/electrochromic window film to dramatically reduce energy lost through windows. While field testing of state-of-the-art electrochromic (EC) windows show the energy savings are maximized if a low-e coating is used in conjunction with the EC, available low-e films have a low visible transmission (~70% or less) that limits the achievable clear state and therefore, appearance and energy savings potential. Comprehensive energy savings models were completed at Lawrence Berkeley National Lab (LBNL). A parametric approach was used to project energy usage for windows with a large range of low-e properties across all U.S. climate zones, without limiting the study to materials that had already been produced commercially or made in a lab. The model enables projection of energy savings for low-e films as well as integrated low-e/EC products. This project developed a novel low-e film, optimized for compatibility with EC windows, using low temperature, high deposition rate processes for the growth of low-e coatings on plastic films by microwave plasma enhanced chemical vapor deposition. Silica films with good density and optical properties were demonstrated at deposition rates as high as 130Å/sec. A simple bi-layer low-e stack

  2. Technology for low cost solid rocket boosters.

    NASA Technical Reports Server (NTRS)

    Ciepluch, C.

    1971-01-01

    A review of low cost large solid rocket motors developed at the Lewis Research Center is given. An estimate is made of the total cost reduction obtainable by incorporating this new technology package into the rocket motor design. The propellant, case material, insulation, nozzle ablatives, and thrust vector control are discussed. The effect of the new technology on motor cost is calculated for a typical expandable 260-in. booster application. Included in the cost analysis is the influence of motor performance variations due to specific impulse and weight changes. It is found for this application that motor costs may be reduced by up to 30% and that the economic attractiveness of future large solid rocket motors will be improved when the new technology is implemented.

  3. Design of a portable powered seat lift

    NASA Technical Reports Server (NTRS)

    Weddendorf, Bruce

    1993-01-01

    People suffering from degenerative hip or knee joints find sitting and rising from a seated position very difficult. These people can rely on large stationary chairs at home, but must ask others for assistance when rising from any other chair. An orthopedic surgeon identified to the MSFC Technology Utilization Office the need for development of a portable device that could perform a similar function to the stationary lift chairs. The MSFC Structural Development Branch answered the Technology Utilization Office's request for design of a portable powered seat lift. The device is a seat cushion that opens under power, lifting the user to near-standing positions. The largest challenge was developing a mechanism to provide a stable lift over the large range of motion needed, and fold flat enough to be comfortable to sit on. CAD 3-D modeling was used to generate complete drawings for the prototype, and a full-scale working model of the Seat lift was made based on the drawings. The working model is of low strength, but proves the function of the mechanism and the concept.

  4. System design for 3D wound imaging using low-cost mobile devices

    NASA Astrophysics Data System (ADS)

    Sirazitdinova, Ekaterina; Deserno, Thomas M.

    2017-03-01

    The state-of-the art method of wound assessment is a manual, imprecise and time-consuming procedure. Per- formed by clinicians, it has limited reproducibility and accuracy, large time consumption and high costs. Novel technologies such as laser scanning microscopy, multi-photon microscopy, optical coherence tomography and hyper-spectral imaging, as well as devices relying on the structured light sensors, make accurate wound assessment possible. However, such methods have limitations due to high costs and may lack portability and availability. In this paper, we present a low-cost wound assessment system and architecture for fast and accurate cutaneous wound assessment using inexpensive consumer smartphone devices. Computer vision techniques are applied either on the device or the server to reconstruct wounds in 3D as dense models, which are generated from images taken with a built-in single camera of a smartphone device. The system architecture includes imaging (smartphone), processing (smartphone or PACS) and storage (PACS) devices. It supports tracking over time by alignment of 3D models, color correction using a reference color card placed into the scene and automatic segmentation of wound regions. Using our system, we are able to detect and document quantitative characteristics of chronic wounds, including size, depth, volume, rate of healing, as well as qualitative characteristics as color, presence of necrosis and type of involved tissue.

  5. Hand-drawn&written pen-on-paper electrochemiluminescence immunodevice powered by rechargeable battery for low-cost point-of-care testing.

    PubMed

    Yang, Hongmei; Kong, Qingkun; Wang, Shaowei; Xu, Jinmeng; Bian, Zhaoquan; Zheng, Xiaoxiao; Ma, Chao; Ge, Shenguang; Yu, Jinghua

    2014-11-15

    In this paper, a pen-on-paper electrochemiluminescence (PoP-ECL) device was entirely hand drawn and written in commercially available crayon and pencil in turn for the first time, and a constant potential-triggered sandwich-type immunosensor was introduced into the PoP-ECL device to form a low-cost ECL immunodevice proof. Each PoP-ECL device contained a hydrophilic paper channel and two PoP electrodes, and the PoP-ECL device was produced as follows: crayon was firstly used to draw hydrophobic regions on pure cellulose paper to create the hydrophilic paper channels followed with a baking treatment, and then a 6B-type black pencil with low resistivity was applied for precision writing, as the PoP electrodes, across the hydrophilic paper channel. For further point-of-care testing, a portable, low-cost rechargeable battery was employed as the power source to provide constant potential to the PoP electrodes to trigger the ECL. Using Carbohydrate antigen 199 as model analyte, this PoP-ECL immunodevice showed a good linear response range from 0.01-200 U mL(-1) with a detection limit of 0.0055 U mL(-1), a high sensitivity and stability. The proposed PoP-ECL immunodevice could be used in point-of-care testing of other tumor markers for remote regions and developing countries. Copyright © 2014 Elsevier B.V. All rights reserved.

  6. Development of a low cost portable fluorometry technology and quantification of cannabinoids in body fluids

    DOT National Transportation Integrated Search

    1977-05-04

    Technology was developed for determining delta sup 9-tetrahydrocannabinol (I) and its major metabolite 11-nor-delta sup 9-tetrahydrocannabinol-9-carboxylic acid (II) in human blood plasma utilizing high pressure liquid chromatography (hplc)-ultraviol...

  7. [Measles epidemic in a highly developed country: low mortality, high morbidity and extensive costs].

    PubMed

    Donas, A; Marty-Nussbaumer, A; Roost, H-P; Neuhaus, T J

    2014-01-01

    Vaccination with 2 doses of > 95% of the population is necessary to eliminate measles. In Switzerland and especially in the central part, vaccine coverage is low (2006: 65%). This led 2006-2009 to a measles epidemic with thousands of cases and high costs. One death was noted in a formerly healthy 12 year old girl. All measles cases, either hospitalized or reported to the authority, in the canton Lucerne between 2006 and 2009 were included. Course, complications, immunization rates and costs of the hospitalized children were analyzed. A total of 1 041 cases of measles were recorded; 758 (73%) were children < 16 years of age. 56 (6%) of the patients were admitted to hospital; half of them were children (n=26, admission rate 3.4%). Main complications were pneumonia with oxygen requirement (n=19), bacterial infections of the base of the skull (n=2) and acute measles encephalitis (n=3). One child each developed acute appendicitis and diabetes mellitus type 1. No death was noted. Median hospitalisation costs were 18 780 CHF. The surveillance system was incomplete: Every third admitted child was not reported to the authority. Due to low vaccine coverage measles still account for epidemics with high morbidity and extensive costs. Instant reporting of all cases is crucial for disease control. Early identification of persons at risk allows timely immunization. Switzerland will remain of central importance to eliminate measles in Europe by 2015. © Georg Thieme Verlag KG Stuttgart · New York.

  8. Use of low orbital satellite communications systems for humanitarian programs

    NASA Technical Reports Server (NTRS)

    Vlasov, Vladimir N.; Gorkovoy, Vladimir

    1991-01-01

    Communication and information exchange play a decisive role in progress and social development. However, in many parts of the world the communication infrastructure is inadequate and the capacity for on-line exchange of information may not exist. This is true of underdeveloped countries, remote and relatively inaccessible regions, sites of natural disasters, and of all cases where the resources needed to create complex communication systems are limited. The creation of an inexpensive space communications system to service such areas is therefore a high priority task. In addition to a relatively low-cost space segment, an inexpensive space communications systems requires a large number of ground terminals, which must be relatively inexpensive, energy efficient (using power generated by storage batteries, or solar arrays, etc.), small in size, and must not require highly expert maintenance. The ground terminals must be portable, and readily deployable. Communications satellites in geostationary orbit at altitudes of about 36,000 km are very expensive and require complex and expensive ground stations and launch vehicles. Given current technology, it is categorically impossible to develop inexpensive satellite systems with portable ground terminals using such satellites. To solve the problem of developing an inexpensive satellite communications system that can operate with relatively small ground stations, including portable terminals, we propose to use a system with satellites in low Earth orbit, at an altitude of 900-1500 km. Because low orbital satellites are much closer to the Earth than geostationary ones and require vastly less energy expenditure by the satellite and ground terminals for transmission of messages, a system using them is relatively inexpensive. Such a system could use portable ground terminals no more complex than ordinary mobile police radios.

  9. Large area low-cost space solar cell development

    NASA Technical Reports Server (NTRS)

    Baraona, C. R.; Cioni, J. L.

    1982-01-01

    A development program to produce large-area (5.9 x 5.9 cm) space quality silicon solar cells with a cost goal of 30 $/watt is descibed. Five cell types under investigation include wraparound dielectric, mechanical wraparound and conventional contact configurations with combinations of 2 or 10 ohm-cm resistivity, back surface reflectors and/or fields, and diffused or ion implanted junctions. A single step process to cut cell and cover-glass simultaneously is being developed. A description of cell developments by Applied Solar Energy Corp., Spectrolab and Spire is included. Results are given for cell and array tests, performed by Lockheed, TRW and NASA. Future large solar arrays that might use cells of this type are discussed.

  10. A low cost LST pointing control system

    NASA Technical Reports Server (NTRS)

    Glaese, J. R.; Kennel, H. F.; Nurre, G. S.; Seltzer, S. M.; Shelton, H. L.

    1975-01-01

    Vigorous efforts to reduce costs, coupled with changes in LST guidelines, took place in the Fall of 1974. These events made a new design of the LST and its Pointing and Attitude Control System possible. The major design changes are summarized as: an annular Support Systems Module; removal of image motion compensation; reaction wheels instead of CMG's; a magnetic torquer system to also perform the emergency and backup functions, eliminating the previously required mass expulsion system. Preliminary analysis indicates the Low Cost LST concept can meet the newly defined requirements and results in a significantly reduced development cost.

  11. Low-cost in vitro fertilization: current insights

    PubMed Central

    Teoh, Pek Joo; Maheshwari, Abha

    2014-01-01

    Despite the development of in vitro fertilization (IVF) more than 30 years ago, the cost of treatment remains high. Furthermore, over the years, more sophisticated technologies and expensive medications have been introduced, making IVF increasingly inaccessible despite the increasing need. Globally, the option to undergo IVF is only available to a privileged few. In recent years, there has been growing interest in exploring strategies to reduce the cost of IVF treatment, which would allow the service to be provided in low-resource settings. In this review, we explore the various ways in which the cost of this treatment can be reduced. PMID:25187741

  12. Low-cost encapsulation materials for terrestrial solar cell modules

    NASA Technical Reports Server (NTRS)

    Cuddihy, E. F.; Baum, B.; Willis, P.

    1979-01-01

    The paper presents the findings of material surveys intended to identify low cost materials which could be functional as encapsulants (by 1986) for terrestrial solar cell modules. Economic analyses have indicated that in order to meet the low cost goal of $2.70 per sq m, some or all of the following material technologies must be developed or advanced: (1) UV screening outer covers; (2) elastomeric acrylics; (3) weatherproofing and waterproofing of structural wood and paper products; (4) transparent UV stabilizers for the UV-sensitive transparent pottants; and (5) cost-effective utilization of silicone and fluorocarbon materials.

  13. Multi-100 kW: Planar low cost solar array development

    NASA Technical Reports Server (NTRS)

    1982-01-01

    The applicability of selected low cost options to solar array blanket design was studied by fabricating representative modules and submitting them to thermal cycle environment. Large area (5.9 x 5.9 cm) solar cells of 3 varieties were purchased: (1) Standard wraparound, (2) Copper contacts substituted for the conventional Titanium-Palladium-Silver, and (3) Standard wraparound except with gridded back contact instead of continuous metallization. The baseline cell was purchased to compare fabrication cost and to serve as a control cell during test evaluation of the other two cells. All cells were assembled into either substrate modules where the cell is individually filtered and welded to an integrated Kapton-copper circuit or into a superstrate configuration with 4 cells jointly adhered to a single sheet of microsheet and then welded to the integrated Kapton-copper circuit. Cell quality, particularly in the metallization of contacts, was less than desired. Problems were encountered with copper metallization in laying down a barrier metal which would ohmically bond to the silicon. The cells received were shunted (sintered) or with low contact pull strength (non-sintered), thus leading to the decision to solder rather than weld the copper cells to the Kapton substrate.

  14. Development of Low-Cost Microcontroller-Based Interface for Data Acquisition and Control of Microbioreactor Operation.

    PubMed

    Husain, Abdul Rashid; Hadad, Yaser; Zainal Alam, Muhd Nazrul Hisham

    2016-10-01

    This article presents the development of a low-cost microcontroller-based interface for a microbioreactor operation. An Arduino MEGA 2560 board with 54 digital input/outputs, including 15 pulse-width-modulation outputs, has been chosen to perform the acquisition and control of the microbioreactor. The microbioreactor (volume = 800 µL) was made of poly(dimethylsiloxane) and poly(methylmethacrylate) polymers. The reactor was built to be equipped with sensors and actuators for the control of reactor temperature and the mixing speed. The article discusses the circuit of the microcontroller-based platform, describes the signal conditioning steps, and evaluates the capacity of the proposed low-cost microcontroller-based interface in terms of control accuracy and system responses. It is demonstrated that the proposed microcontroller-based platform is able to operate parallel microbioreactor operation with satisfactory performances. Control accuracy at a deviation less than 5% of the set-point values and responses in the range of few seconds have been recorded. © 2015 Society for Laboratory Automation and Screening.

  15. Portable bacterial identification system based on elastic light scatter patterns.

    PubMed

    Bae, Euiwon; Ying, Dawei; Kramer, Donald; Patsekin, Valery; Rajwa, Bartek; Holdman, Cheryl; Sturgis, Jennifer; Davisson, V Jo; Robinson, J Paul

    2012-08-28

    Conventional diagnosis and identification of bacteria requires shipment of samples to a laboratory for genetic and biochemical analysis. This process can take days and imposes significant delay to action in situations where timely intervention can save lives and reduce associated costs. To enable faster response to an outbreak, a low-cost, small-footprint, portable microbial-identification instrument using forward scatterometry has been developed. This device, weighing 9 lb and measuring 12 × 6 × 10.5 in., utilizes elastic light scatter (ELS) patterns to accurately capture bacterial colony characteristics and delivers the classification results via wireless access. The overall system consists of two CCD cameras, one rotational and one translational stage, and a 635-nm laser diode. Various software algorithms such as Hough transform, 2-D geometric moments, and the traveling salesman problem (TSP) have been implemented to provide colony count and circularity, centering process, and minimized travel time among colonies. Experiments were conducted with four bacteria genera using pure and mixed plate and as proof of principle a field test was conducted in four different locations where the average classification rate ranged between 95 and 100%.

  16. Feasibility of developing a portable driver performance data acquisition system for human factors research: Technical tasks. Volume 1

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Carter, R.J.; Barickman, F.S.; Spelt, P.F.

    1998-01-01

    A two-phase, multi-year research program entitled ``development of a portable driver performance data acquisition system for human factors research`` was recently completed. The primary objective of the project was to develop a portable data acquisition system for crash avoidance research (DASCAR) that will allow drive performance data to be collected using a large variety of vehicle types and that would be capable of being installed on a given vehicle type within a relatively short-time frame. During phase 1 a feasibility study for designing and fabricating DASCAR was conducted. In phase 2 of the research DASCAR was actually developed and validated.more » This technical memorandum documents the results from the feasibility study. It is subdivided into three volumes. Volume one (this report) addresses the last five items in the phase 1 research and the first issue in the second phase of the project. Volumes two and three present the related appendices, and the design specifications developed for DASCAR respectively. The six tasks were oriented toward: identifying parameters and measures; identifying analysis tools and methods; identifying measurement techniques and state-of-the-art hardware and software; developing design requirements and specifications; determining the cost of one or more copies of the proposed data acquisition system; and designing a development plan and constructing DASCAR. This report also covers: the background to the program; the requirements for the project; micro camera testing; heat load calculations for the DASCAR instrumentation package in automobile trunks; phase 2 of the research; the DASCAR hardware and software delivered to the National Highway Traffic Safety Administration; and crash avoidance problems that can be addressed by DASCAR.« less

  17. Symmetric Sodium-Ion Capacitor Based on Na0.44MnO2 Nanorods for Low-Cost and High-Performance Energy Storage.

    PubMed

    Chen, Zhongxue; Yuan, Tianci; Pu, Xiangjun; Yang, Hanxi; Ai, Xinping; Xia, Yongyao; Cao, Yuliang

    2018-04-11

    Batteries and electrochemical capacitors play very important roles in the portable electronic devices and electric vehicles and have shown promising potential for large-scale energy storage applications. However, batteries or capacitors alone cannot meet the energy and power density requirements because rechargeable batteries have a poor power property, whereas supercapacitors offer limited capacity. Here, a novel symmetric sodium-ion capacitor (NIC) is developed based on low-cost Na 0.44 MnO 2 nanorods. The Na 0.44 MnO 2 with unique nanoarchitectures and iso-oriented feature offers shortened diffusion path lengths for both electronic and Na + transport and reduces the stress associated with Na + insertion and extraction. Benefiting from these merits, the symmetric device achieves a high power density of 2432.7 W kg -1 , an improved energy density of 27.9 Wh kg -1 , and a capacitance retention of 85.2% over 5000 cycles. Particularly, the symmetric NIC based on Na 0.44 MnO 2 permits repeatedly reverse-polarity characteristics, thus simplifying energy management system and greatly enhancing the safety under abuse condition. This cost-effective, high-safety, and high-performance symmetric NIC can balance the energy and power density between batteries and capacitors and serve as an electric power source for future low-maintenance large-scale energy storage systems.

  18. A Low-Cost, Effective, Fumes Exhaust System.

    ERIC Educational Resources Information Center

    Jacobs, C. O.

    1979-01-01

    Discusses the importance of avoiding welding fumes. The sources of these fumes are presented in a table. Criticizes currently used ventilation systems and reviews the Occupational Safety and Health Act requirements. Describes a low-cost exhaust system developed for agricultural mechanics laboratories. (LRA)

  19. Multi-Site Simultaneous Time-Resolved Photometry with a Low Cost Electro-Optics System.

    PubMed

    Gasdia, Forrest; Barjatya, Aroh; Bilardi, Sergei

    2017-05-30

    Sunlight reflected off of resident space objects can be used as an optical signal for astrometric orbit determination and for deducing geometric information about the object. With the increasing population of small satellites and debris in low Earth orbit, photometry is a powerful tool in operational support of space missions, whether for anomaly resolution or object identification. To accurately determine size, shape, spin rate, status of deployables, or attitude information of an unresolved resident space object, multi-hertz sample rate photometry is required to capture the relatively rapid changes in brightness that these objects can exhibit. OSCOM, which stands for Optical tracking and Spectral characterization of CubeSats for Operational Missions, is a low cost and portable telescope system capable of time-resolved small satellite photometry, and is field deployable on short notice for simultaneous observation from multiple sites. We present the electro-optical design principles behind OSCOM and light curves of the 1.5 U DICE-2 CubeSat and simultaneous observations of the main body of the ASTRO-H satellite after its fragmentation event.

  20. Low-cost point-focus solar concentrator, phase 1

    NASA Technical Reports Server (NTRS)

    Nelson, E. V.; Derbidge, T. C.; Erskine, D.; Maraschin, R. A.; Niemeyer, W. A.; Matsushita, M. J.; Overly, P. T.

    1979-01-01

    The results of the preliminary design study for the low cost point focus solar concentrator (LCPFSC) development program are presented. A summary description of the preliminary design is given. The design philosophy used to achieve a cost effective design for mass production is described. The concentrator meets all design requirements specified and is based on practical design solutions in every possible way.

  1. Portable Chemical Sterilizer (PCS) for Surgical Instruments

    DTIC Science & Technology

    2004-12-01

    PORTABLE CHEMICAL STERILIZER (PCS) FOR SURGICAL INSTRUMENTS CJ Doona*, FE Feeherry, MA Curtin‡, K Kustin‡, S Kandlikar‡ U.S. Army-Soldier...denotes Contractors) Biomedical Technologies ABSTRACT A novel device called the Portable Chemical Sterilizer (PCS) has been developed for the...rapid, safe, portable, power-free, and convenient sterilization of objects or surfaces contaminated with pathogenic microorganisms that cause

  2. Study of CdTe/CdS solar cell at low power density for low-illumination applications

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Devi, Nisha, E-mail: nishatanwer1989@gmail.com; Aziz, Anver, E-mail: aaziz@jmi.ac.in; Datta, Shouvik

    In this paper, we numerically investigate CdTe/CdS PV cell properties using a simulation program Solar Cell Capacitance Simulator in 1D (SCAPS-1D). A simple structure of CdTe PV cell has been optimized to study the effect of temperature, absorber thickness and work function at very low incident power. Objective of this research paper is to build an efficient and cost effective solar cell for portable electronic devices such as portable computers and cell phones that work at low incident power because most of such devices work at diffused and reflected sunlight. In this report, we simulated a simple CdTe PV cellmore » at very low incident power, which gives good efficiency.« less

  3. The development of a low-cost laser communication system for the classroom

    NASA Astrophysics Data System (ADS)

    Sparks, Robert T.; Pompea, Stephen M.; Walker, Constance E.

    2007-06-01

    Hands-On Optics (HOO) is a National Science Foundation funded program to bring optics education to underserved middle school students. We have developed the culminating module (Module 6) on laser communication. Students learn how lasers can be modulated to carry information. The main activity of this module is the construction of a low-cost laser communication system. The system can be built using parts readily available at a local electronics store for approximately US $60. The system can be used to transmit a person's voice or music from sources such as an mp3 player or radio over a distance of 350 feet. We will provide detailed plans on how to build the system in this paper.

  4. System identification of a small low-cost unmanned aerial vehicle using flight data from low-cost sensors

    NASA Astrophysics Data System (ADS)

    Hoffer, Nathan Von

    Remote sensing has traditionally been done with satellites and manned aircraft. While. these methods can yield useful scientificc data, satellites and manned aircraft have limitations in data frequency, process time, and real time re-tasking. Small low-cost unmanned aerial vehicles (UAVs) provide greater possibilities for personal scientic research than traditional remote sensing platforms. Precision aerial data requires an accurate vehicle dynamics model for controller development, robust flight characteristics, and fault tolerance. One method of developing a model is system identification (system ID). In this thesis system ID of a small low-cost fixed-wing T-tail UAV is conducted. The linerized longitudinal equations of motion are derived from first principles. Foundations of Recursive Least Squares (RLS) are presented along with RLS with an Error Filtering Online Learning scheme (EFOL). Sensors, data collection, data consistency checking, and data processing are described. Batch least squares (BLS) and BLS with EFOL are used to identify aerodynamic coecoefficients of the UAV. Results of these two methods with flight data are discussed.

  5. A field portable mass spectrometer for monitoring organic vapors.

    PubMed

    Meier, R W

    1978-03-01

    A portable mass spectrometer has been designed and built under the sponsorship of the US Army for the purpose of monitoring low concentrations of specified organics in the ambient atmosphere. The goals of the development were discrimination, sensitivity, portability, simplicity of operation, economy and convenience. These objectives were met in a system consisting of a computer operated mass spectrometer with a Llewellyn membrane separator inlet system housed in two 26 x 18 x 9 inch aluminum cases with a total weight less than 150 pounds. This system has shown the capability for field detection of hundreds of specific organic vapors at the parts per billion level in the ambient and workplace environments.

  6. Portable Multigas Monitors for International Space Station

    NASA Technical Reports Server (NTRS)

    Mudgett, Paul D.; Pilgrim, Jeffrey S.; Ruff, Gary A.

    2011-01-01

    The Environmental Health System (EHS) on International Space Station (ISS) includes portable instruments to measure various cabin gases that acutely impact crew health. These hand-held devices measure oxygen, carbon dioxide, carbon monoxide, hydrogen chloride and hydrogen cyanide. The oxygen and carbon dioxide units also serve to back up key functions of the Major Constituent Analyzers. Wherever possible, commercial off-the-shelf (COTS) devices are employed by EHS to save development and sustaining costs. COTS hardware designed for general terrestrial applications however has limitations such as no pressure compensation, limited life of the active sensor, calibration drift, battery issues, unpredictable vendor support and obsolescence. The EHS fleet (inflight and ground inventory) of instruments is both aging and dwindling in number. With the retirement of the US Space Shuttle, maintenance of on-orbit equipment becomes all the more difficult. A project is underway to search for gas monitoring technology that is highly reliable and stable for years. Tunable Diode Laser Spectroscopy (TDLS) seems to be the front-runner technology, but generally is not yet commercially available in portable form. NASA has fostered the development of TDLS through the Small Business Innovative Research (SBIR) program. A number of gases of interest to the aerospace and submarine communities can be addressed by TDLS including the list mentioned above plus hydrogen fluoride, ammonia and water (humidity). There are several different forms of TDLS including photoacoustic and direct absorption spectroscopy using various multipass cell geometries. This paper describes the history of portable gas monitoring on NASA spacecraft and provides a status of the development of TDLS based instruments. Planned TDLS flight experiments on ISS could lead both to operational use on ISS and important roles in future Exploration spacecraft and habitats.

  7. Development of a Portable AC/DC Welding Power Supply Module

    DTIC Science & Technology

    1975-03-01

    REPORT DATE MAR 1975 2. REPORT TYPE N/A 3. DATES COVERED - 4. TITLE AND SUBTITLE Development of a Portable AC /DC Welding Power Supply...achieved. Additional bypass capacitors were added to reduce further switch heating and voltage transients. November AC welding was achieved with...Investigate the conversion of inversion frequency back to 60 Hz for AC welding. 4) Investigate a 120V single phase mini supply. VI I Objectives A) Goals

  8. Development of a portable preconcentrator/ion mobility spectrometer system for the trace detection of narcotics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Parmeter, J.E.; Custer, C.A.

    This project was supported by LDRD funding for the development and preliminary testing of a portable narcotics detection system. The system developed combines a commercial trace detector known as an ion mobility spectrometer (IMS) with a preconcentrator originally designed by Department 5848 for the collection of explosives molecules. The detector and preconcentrator were combined along with all necessary accessories onto a push cart, thus yielding a fully portable detection unit. Preliminary testing with both explosives and narcotics molecules shown that the system is operational, and that it can successfully detect drugs as marijuana, methamphetamine (speed), and cocaine based on theirmore » characteristics IMS signatures.« less

  9. Performance Analysis and Portability of the PLUM Load Balancing System

    NASA Technical Reports Server (NTRS)

    Oliker, Leonid; Biswas, Rupak; Gabow, Harold N.

    1998-01-01

    The ability to dynamically adapt an unstructured mesh is a powerful tool for solving computational problems with evolving physical features; however, an efficient parallel implementation is rather difficult. To address this problem, we have developed PLUM, an automatic portable framework for performing adaptive numerical computations in a message-passing environment. PLUM requires that all data be globally redistributed after each mesh adaption to achieve load balance. We present an algorithm for minimizing this remapping overhead by guaranteeing an optimal processor reassignment. We also show that the data redistribution cost can be significantly reduced by applying our heuristic processor reassignment algorithm to the default mapping of the parallel partitioner. Portability is examined by comparing performance on a SP2, an Origin2000, and a T3E. Results show that PLUM can be successfully ported to different platforms without any code modifications.

  10. A portable high-definition electronic endoscope based on embedded system

    NASA Astrophysics Data System (ADS)

    Xu, Guang; Wang, Liqiang; Xu, Jin

    2012-11-01

    This paper presents a low power and portable highdefinition (HD) electronic endoscope based on CortexA8 embedded system. A 1/6 inch CMOS image sensor is used to acquire HD images with 1280 *800 pixels. The camera interface of A8 is designed to support images of various sizes and support multiple inputs of video format such as ITUR BT601/ 656 standard. Image rotation (90 degrees clockwise) and image process functions are achieved by CAMIF. The decode engine of the processor plays back or records HD videos at speed of 30 frames per second, builtin HDMI interface transmits high definition images to the external display. Image processing procedures such as demosaicking, color correction and auto white balance are realized on the A8 platform. Other functions are selected through OSD settings. An LCD panel displays the real time images. The snapshot pictures or compressed videos are saved in an SD card or transmited to a computer through USB interface. The size of the camera head is 4×4.8×15 mm with more than 3 meters working distance. The whole endoscope system can be powered by a lithium battery, with the advantages of miniature, low cost and portability.

  11. Development of a Low Cost, Compact, Spectrophotometric pH Sensor

    NASA Astrophysics Data System (ADS)

    Spaulding, R. S.; Darlington, R. C.; Beck, J. C.; DeGrandpre, M. D.

    2016-02-01

    Understanding the ecological impacts of oceanic CO2 uptake in the post-industrial world requires high spatial and temporal resolution measurements of inorganic carbon. Most researchers aim for measuring two of the four inorganic carbon parameters (partial pressure of CO2, total alkalinity, total dissolve inorganic carbon, and pH), in order to fully characterize the carbonate system. While this is desirable in many circumstances, in some cases it may be possible to fully characterize the system using pH and salinity, or even to use pH alone as a proxy to the health of calcifying marine organisms. The development of relatively inexpensive spectrophotometric pH sensors compatible with Lagrangian drifters would greatly improve the ability of researchers to characterize the changing oceanic carbonate system. We have designed and tested a novel, miniaturized, submersible, autonomous opto-fluidic device that can be manufactured at a relatively low cost. The flexible design can be deployed independent of or in tandem with GDP style drifters and will enable spectrophotometric pH technology on a host of drifting platforms and buoys. This device uses a dual wavelength light emitting diode (LED) light source, low volume mixer, and an optical flow-cell mounted to the electronic controller board. Laboratory testing shows that this device measures pH with similar accuracy and precision to other spectrophotometric methods such as the SAMI-pH.

  12. On-site Rapid Diagnosis of Intracranial Hematoma using Portable Multi-slice Microwave Imaging System.

    PubMed

    Mobashsher, Ahmed Toaha; Abbosh, A M

    2016-11-29

    Rapid, on-the-spot diagnostic and monitoring systems are vital for the survival of patients with intracranial hematoma, as their conditions drastically deteriorate with time. To address the limited accessibility, high costs and static structure of currently used MRI and CT scanners, a portable non-invasive multi-slice microwave imaging system is presented for accurate 3D localization of hematoma inside human head. This diagnostic system provides fast data acquisition and imaging compared to the existing systems by means of a compact array of low-profile, unidirectional antennas with wideband operation. The 3D printed low-cost and portable system can be installed in an ambulance for rapid on-site diagnosis by paramedics. In this paper, the multi-slice head imaging system's operating principle is numerically analysed and experimentally validated on realistic head phantoms. Quantitative analyses demonstrate that the multi-slice head imaging system is able to generate better quality reconstructed images providing 70% higher average signal to clutter ratio, 25% enhanced maximum signal to clutter ratio and with around 60% hematoma target localization compared to the previous head imaging systems. Nevertheless, numerical and experimental results demonstrate that previous reported 2D imaging systems are vulnerable to localization error, which is overcome in the presented multi-slice 3D imaging system. The non-ionizing system, which uses safe levels of very low microwave power, is also tested on human subjects. Results of realistic phantom and subjects demonstrate the feasibility of the system in future preclinical trials.

  13. Low-cost bioanalysis on paper-based and its hybrid microfluidic platforms.

    PubMed

    Dou, Maowei; Sanjay, Sharma Timilsina; Benhabib, Merwan; Xu, Feng; Li, XiuJun

    2015-12-01

    Low-cost assays have broad applications ranging from human health diagnostics and food safety inspection to environmental analysis. Hence, low-cost assays are especially attractive for rural areas and developing countries, where financial resources are limited. Recently, paper-based microfluidic devices have emerged as a low-cost platform which greatly accelerates the point of care (POC) analysis in low-resource settings. This paper reviews recent advances of low-cost bioanalysis on paper-based microfluidic platforms, including fully paper-based and paper hybrid microfluidic platforms. In this review paper, we first summarized the fabrication techniques of fully paper-based microfluidic platforms, followed with their applications in human health diagnostics and food safety analysis. Then we highlighted paper hybrid microfluidic platforms and their applications, because hybrid platforms could draw benefits from multiple device substrates. Finally, we discussed the current limitations and perspective trends of paper-based microfluidic platforms for low-cost assays. Copyright © 2015 Elsevier B.V. All rights reserved.

  14. An easy-to-operate portable pulse-height analysis system for area monitoring with TEPC in radiation protection

    NASA Astrophysics Data System (ADS)

    Kunz, A.; Pihet, P.; Arend, E.; Menzel, H. G.

    1990-12-01

    A portable area monitor for the measurement of dose-equivalent quantities in practical radiation-protection work has been developed. The detector applied is a low-pressure proportional counter (TEPC) used in microdosimetry. The complex analysis system required has been optimized with regard to low power consumption and small size to achieve a real operational survey meter. The newly designed electronic includes complete analog, digital and microprocessor boards. It presents the characteristic of fast pulse-height processing over a large (5 decades) dynamic range. Three original circuits have been specifically developed, consisting of: (1) a miniaturized adjustable high-voltage power supply with low ripple and high stability; (2) a double spectroscopy amplifier with constant gain ratio and common pole-zero stage; and (3) an analog-to-digital converter with quasi-logarithmic characteristics based on a flash converter using fast comparators associated in parallel. With the incorporated single-board computer, the maximal total power consumption is 5 W, enabling 40 hours operation time with batteries. With minor adaptations the equipment is proposed as a low-cost solution for various measuring problems in environmental studies.

  15. Development and evaluation of a low cost probe-type instrument to measure the equilibrium moisture content of grain

    USDA-ARS?s Scientific Manuscript database

    Storage bags are common in Africa, Asia and many other less developed countries therefore a grain probing method is well-suited for moisture content (MC) measurement. A low cost meter was developed as part of a USAID project to reduce the post-harvest loss (PHL). The meter measures the MC of maize a...

  16. Development of an NCHRP report 350 TL-3 New Jersey shape 50-inch portable concrete barrier : executive summary report.

    DOT National Transportation Integrated Search

    2006-06-01

    The purpose of the project was to develop a : temporary portable concrete barrier (PCB) : with an integral glare shield for use in : roadside work-zone areas. Currentlyavailable : 32-inch portable concrete barriers : require the use of an add-on glar...

  17. Obstacles encountered in the development of the low vision enhancement system.

    PubMed

    Massof, R W; Rickman, D L

    1992-01-01

    The Johns Hopkins Wilmer Eye Institute and the NASA Stennis Space Center are collaborating on the development of a new high technology low vision aid called the Low Vision Enhancement System (LVES). The LVES consists of a binocular head-mounted video display system, video cameras mounted on the head-mounted display, and real-time video image processing in a system package that is battery powered and portable. Through a phased development approach, several generations of the LVES can be made available to the patient in a timely fashion. This paper describes the LVES project with major emphasis on technical problems encountered or anticipated during the development process.

  18. Development of a Low-Cost UAV Doppler Radar Data System

    NASA Technical Reports Server (NTRS)

    Knuble, Joseph; Li, Lihua; Heymsfield, Gerry

    2005-01-01

    A viewgraph presentation on the design of a low cost unmanned aerial vehicle (UAV) doppler radar data system is presented. The topics include: 1) Science and Mission Background; 2) Radar Requirements and Specs; 3) Radar Realization: RF System; 4) Processing of RF Signal; 5) Data System Design Process; 6) Can We Remove the DSP? 7) Determining Approximate Speed Requirements; 8) Radar Realization: Data System; 9) Data System Operation; and 10) Results.

  19. Conestoga 2: A low cost commercial space transport system

    NASA Technical Reports Server (NTRS)

    Rasmussen, R. O.

    1984-01-01

    Conestoga 2 is currently under development. It is capable of inserting 500 Kg satellites into 800 Km circular polar orbits. Conestoga 2 makes maximum use of existing (developed) technology and hardware. Its commercial objective is to fill a need for low cost low Earth orbital transport not efficiently served by Shuttle or larger space transport systems. Low Earth orbit markets, foreign participation, and launch site considerations are discussed along with technical and economic trade-offs.

  20. Novel Structured Metal Bipolar Plates for Low Cost Manufacturing

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, Conghua

    2013-08-15

    Bipolar plates are an important component in fuel cell stacks and accounts for more than 75% of stack weight and volume, and 20% of the stack cost. The technology development of metal bipolar plates can effectively reduce the fuel cells stack weight and volume over 50%. The challenge is to protect metal plate from corrosion at low cost for the broad commercial applications. While most of today’s PEM fuel cell metallic bipolar plate technologies use some precious metal, the focus of this SBIR project is to develop a low cost, novel nano-structured metal bipolar plate technology without using any preciousmore » metal. The technology will meet the performance and cost requirements for automobile applications. Through the Phase I project, TreadStone has identified the corrosion resistant and electrically conductive titanium oxide for the metal bipolar plate surface protection for automotive PEM fuel cell applications. TreadStone has overcome the manufacturing issues to apply the coating on metal substrate surface, and has demonstrated the feasibility of the coated stainless steel plates by ex-situ evaluation tests and the in-situ fuel cell long term durability test. The test results show the feasibility of the proposed nano-structured coating as the low cost metal bipolar plates of PEM fuel cells. The plan for further technology optimization is also outlined for the Phase II project.« less

  1. RAL Low-cost Ionosonde System

    NASA Astrophysics Data System (ADS)

    Stamper, R.; Davis, C. J.; Bradford, W. J.; Hapgood, M. A.; McCrea, I. W.

    2009-04-01

    Ionosondes continue to be important for the study of the ionosphere; they are relatively cheap and simple to install and operate, so can be distributed widely across the globe; they can give information on plasma density, structure and motion; their direct measurements of electron densities are also important for calibrating other more complicated observation methods such as incoherent scatter radar, satellite beacon tomography and radio occultation. The low cost of sounders, however, is relative to facilities such as space-based instrumentation and incoherent scatter radars; one type of ionosonde widely used for monitoring costs in excess of €150,000, representing a significant investment for many organisations. A new instrument design is under development at RAL for a low-power sounder using pulse-coding techniques to get good signal-to-noise. The design uses COTS components wherever possible, and has a projected cost in the region of €6,000 for the simplest version, making such a system accessible to all. The design is tiered so that the simplest version would give information about layer heights and electron densities, but adding multiple receivers would enable plasma velocities and echo direction to be determined, increasing the science output. The intention is that sounders of this new design be installed widely, in particular in developing nations. This would be especially beneficial for study of the equatorial and low-latitude ionosphere, which is relatively poorly understood because of a relative lack of instrumentation in this region. A wide range of studies would be enabled or enhanced by a much denser network of ionosondes across Africa, South America and Asia including: study of planetary-scale oscillations and gravity waves in the ionosphere; investigation of longitudinal variation in the equatorial electrojet and equatorial anomaly; examination of mechanisms for vertical coupling in the atmosphere with, for example, global thunderstorm activity

  2. RAL Low-Cost Ionosonde System

    NASA Astrophysics Data System (ADS)

    Stamper, R.; Davis, C.; Bradford, J.

    2005-12-01

    Ionosondes continue to be important for the study of the ionosphere; they are relatively cheap and simple to install and operate, so can be distributed widely across the globe; they can give information on plasma density, structure and motion; their direct measurements of electron densities are also important for calibrating other more complicated observation methods such as incoherent scatter radar, satellite beacon tomography and radio occultation. The low cost of sounders, however, is relative to facilities such as space-based instrumentation and incoherent scatter radars; one type of ionosonde widely used for monitoring costs in excess of 200,000, representing a significant investment for many organisations. A new instrument design is under development at RAL for a low-power sounder using pulse-coding techniques to get good signal-to-noise. The design uses COTS components wherever possible, and has a projected cost in the region of 7,500 for the simplest version, making such a system accessible to all. The design is tiered so that the simplest version would give information about layer heights and electron densities, but adding multiple receivers would enable plasma velocities and echo direction to be determined, increasing the science output. The intention is that sounders of this new design be installed widely, in particular in developing nations. This would be especially beneficial for study of the equatorial and low-latitude ionosphere, which is relatively poorly understood because of a relative lack of instrumentation in this region. A wide range of studies would be enabled or enhanced by a much denser network of ionosondes across Africa, South America and Asia including: study of planetary-scale oscillations and gravity waves in the ionosphere; investigation of longitudinal variation in the equatorial electrojet and equatorial anomaly; examination of mechanisms for vertical coupling in the atmosphere with, for example, global thunderstorm activity being

  3. Low-cost, portable fire hose tester

    NASA Technical Reports Server (NTRS)

    Jocke, R. F.; Miller, R. E.

    1975-01-01

    Availability of pumping unit permits scheduling and performing required periodic hose tests in proper manner while retaining full fire equipment readiness. Use of pumping unit preserves operating life and capability of pumper truck.

  4. Technology for low-cost PIR security sensors

    NASA Astrophysics Data System (ADS)

    Liddiard, Kevin C.

    2008-03-01

    Current passive infrared (PIR) security sensors employing pyroelectric detectors are simple, cheap and reliable, but have several deficiencies. These sensors, developed two decades ago, are essentially short-range moving-target hotspot detectors. They cannot detect slow temperature changes, and thus are unable to respond to radiation stimuli indicating potential danger such as overheating electrical appliances and developing fires. They have a poor optical resolution and limited ability to recognize detected targets. Modern uncooled thermal infrared technology has vastly superior performance but as yet is too costly to challenge the PIR security sensor market. In this paper microbolometer technology will be discussed which can provide enhanced performance at acceptable cost. In addition to security sensing the technology has numerous applications in the military, industrial and domestic markets where target range is short and low cost is paramount.

  5. Rapid, Affordable and Portable Medium-Throughput Molecular Device for Zika Virus

    PubMed Central

    Chan, Kamfai; Weaver, Scott C.; Wong, Pui-Yan; Lie, Sherly; Wang, Eryu; Guerbois, Mathilde; Vayugundla, Siva Praneeth; Wong, Season

    2016-01-01

    Zika virus (ZIKV) has gained global attention as an etiologic agent of fetal microcephaly and Guillain-Barré syndrome. Existing immuno-based rapid tests often fail to distinguish between Zika and related flaviviruses that are common in affected regions of Central and South Americas and the Caribbean. The US CDC and qualified state health department laboratories can perform the reverse transcription polymerase chain reaction (RT-PCR) ZIKV test using highly sophisticated instruments with long turnaround times. The preliminary results of a portable and low-cost molecular diagnostics system for ZIKV infection are reported here. In less than 15 minutes, this low-cost platform can automatically perform high quality RNA extraction from up to 12 ZIKV-spiked urine samples simultaneously. It can also perform reverse transcription recombinase polymerase amplification reaction (RT-RPA) in ≤15 minutes. The fluorescent signal produced from probe-based RT-RPA or RT-PCR assays can be monitored using LEDs and a smartphone camera. In addition, the RT-RPA and RT-PCR assays do not cross-react with dengue and chikungunya viral RNA. This low-cost system lacks complicated, sensitive and high cost components, making it suitable for resource-limited settings. It has the potential to offer simple sample-to-answer molecular diagnostics and can inform healthcare workers of patients’ diagnosis promptly. PMID:27934884

  6. A simple low cost latent fingerprint sensor based on deflectometry and WFT analysis

    NASA Astrophysics Data System (ADS)

    Dhanotia, Jitendra; Chatterjee, Amit; Bhatia, Vimal; Prakash, Shashi

    2018-02-01

    In criminal investigations, latent fingerprints are one of the most significant forms of evidence and most commonly used forensic investigation tool worldwide. The existing non-contact latent fingerprint detection systems are bulky, expensive and require environment which is shock and vibration resistant, thereby limiting their usability outside the laboratory. In this article, a compact, full field, low cost technique for profiling of fingerprints using deflectometry is proposed. Using inexpensive mobile phone screen based structured illumination, and windowed Fourier transform (WFT) based phase retrieval mechanism, the 2D and 3D phase plots reconstruct the profile information of the fingerprint. The phase information is also used to confirm a match between two fingerprints in real time. Since the proposed technique is non-interferometric, the measurements are least affected by environmental perturbations. Using the proposed technique, a portable sensor capable of field deployment has been realized.

  7. A low cost thermal infrared hyperspectral imager for small satellites

    NASA Astrophysics Data System (ADS)

    Crites, S. T.; Lucey, P. G.; Wright, R.; Garbeil, H.; Horton, K. A.

    2011-06-01

    The traditional model for space-based earth observations involves long mission times, high cost, and long development time. Because of the significant time and monetary investment required, riskier instrument development missions or those with very specific scientific goals are unlikely to successfully obtain funding. However, a niche for earth observations exploiting new technologies in focused, short lifetime missions is opening with the growth of the small satellite market and launch opportunities for these satellites. These low-cost, short-lived missions provide an experimental platform for testing new sensor technologies that may transition to larger, more long-lived platforms. The low costs and short lifetimes also increase acceptable risk to sensors, enabling large decreases in cost using commercial off the shelf (COTS) parts and allowing early-career scientists and engineers to gain experience with these projects. We are building a low-cost long-wave infrared spectral sensor, funded by the NASA Experimental Project to Stimulate Competitive Research program (EPSCOR), to demonstrate the ways in which a university's scientific and instrument development programs can fit into this niche. The sensor is a low-mass, power efficient thermal hyperspectral imager with electronics contained in a pressure vessel to enable the use of COTS electronics, and will be compatible with small satellite platforms. The sensor, called Thermal Hyperspectral Imager (THI), is based on a Sagnac interferometer and uses an uncooled 320x256 microbolometer array. The sensor will collect calibrated radiance data at long-wave infrared (LWIR, 8-14 microns) wavelengths in 230-meter pixels with 20 wavenumber spectral resolution from a 400-km orbit.

  8. Regulatory Considerations of Lower Cost Air Pollution Sensor Data Performance

    EPA Science Inventory

    Low-cost, portable air quality sensors could be the next generation of air monitoring, however, this nascent technology is not without risk. This article looks at how the U.S. Environmental Protection Agency (EPA) uses air monitoring data, the procedures followed to ensure and a...

  9. Development of a simple, low cost, indirect ion beam fluence measurement system for ion implanters, accelerators

    NASA Astrophysics Data System (ADS)

    Suresh, K.; Balaji, S.; Saravanan, K.; Navas, J.; David, C.; Panigrahi, B. K.

    2018-02-01

    We developed a simple, low cost user-friendly automated indirect ion beam fluence measurement system for ion irradiation and analysis experiments requiring indirect beam fluence measurements unperturbed by sample conditions like low temperature, high temperature, sample biasing as well as in regular ion implantation experiments in the ion implanters and electrostatic accelerators with continuous beam. The system, which uses simple, low cost, off-the-shelf components/systems and two distinct layers of in-house built softwarenot only eliminates the need for costly data acquisition systems but also overcomes difficulties in using properietry software. The hardware of the system is centered around a personal computer, a PIC16F887 based embedded system, a Faraday cup drive cum monitor circuit, a pair of Faraday Cups and a beam current integrator and the in-house developed software include C based microcontroller firmware and LABVIEW based virtual instrument automation software. The automatic fluence measurement involves two important phases, a current sampling phase lasting over 20-30 seconds during which the ion beam current is continuously measured by intercepting the ion beam and the averaged beam current value is computed. A subsequent charge computation phase lasting 700-900 seconds is executed making the ion beam to irradiate the samples and the incremental fluence received by the sampleis estimated usingthe latest averaged beam current value from the ion beam current sampling phase. The cycle of current sampling-charge computation is repeated till the required fluence is reached. Besides simplicity and cost-effectiveness, other important advantages of the developed system include easy reconfiguration of the system to suit customisation of experiments, scalability, easy debug and maintenance of the hardware/software, ability to work as a standalone system. The system was tested with different set of samples and ion fluences and the results were verified using

  10. Low cost balancing unit design

    NASA Astrophysics Data System (ADS)

    Golembiovsky, Matej; Dedek, Jan; Slanina, Zdenek

    2017-06-01

    This article deals with the design of a low-cost balancing system which consist of battery balancing units, accumulator pack units and coordinator unit with interface for higher level of battery management system. This solution allows decentralized mode of operation and the aim of this work is implementation of controlling and diagnostic mechanism into an electric scooter project realized at Technical university of Ostrava. In todays world which now fully enjoys the prime of electromobility, off-grid battery systems and other, it is important to seek the optimal balance between functionality and the economy side of BMS that being electronics which deals with secondary cells of batery packs. There were numerous sophisticated, but not too practical BMS models in the past, such as centralized system or standalone balance modules of individual cells. This article aims at development of standalone balance modules which are able to communicate with the coordinator, adjust their parameters and ensure their cells safety in case of a communication failure. With the current worldwide cutting cost trend in mind, the emphasis was put on the lowest price possible for individual component. The article is divided into two major categories, the first one being desing of power electronics with emphasis on quality, safety (cooling) and also cost. The second part describes development of a communication interface with reliability and cost in mind. The article contains numerous graphs from practical measurements. The outcome of the work and its possible future is defined in the conclusion.

  11. A portable circulating tumor cell capture microdevice

    NASA Astrophysics Data System (ADS)

    Datar, Ram H.

    2009-03-01

    Sensitive detection of earliest metastatic spread of tumors in a minimally invasive and user-friendly manner will revolutionize the clinical management of cancer patients. The current methodologies for circulating tumor cell (CTC) capture and identification have significant limitations including time, cost, limited capture efficiency and lack of standardization. We have developed and optimized a novel parylene membrane filter-based portable microdevice for size-based isolation of CTC from human peripheral blood. Following characterization with a model system to study the recovery rate and enrichment factor, a comparison of the microdevice with the commercially available system using blood from cancer patients demonstrated superior recovery rate and the promise of clinical utility of the microdevice. The development of the microdevice and its potential clinical applicability will be discussed.

  12. A portable battery powered microfluidic impedance cytometer with smartphone readout: towards personal health monitoring.

    PubMed

    Talukder, Niloy; Furniturewalla, Abbas; Le, Tuan; Chan, Matthew; Hirday, Shreyas; Cao, Xinnan; Xie, Pengfei; Lin, Zhongtian; Gholizadeh, Azam; Orbine, Steve; Javanmard, Mehdi

    2017-06-01

    We present a portable system for personalized blood cell counting consisting of a microfluidic impedance cytometer and portable analog readout electronics, feeding into an analog-to-digital converter (ADC), and being transmitted via Bluetooth to a user-accessible mobile application. We fabricated a microfluidic impedance cytometer with a novel portable analog readout. The novel design of the analog readout, which consists of a lock-in-amplifier followed by a high-pass filter stage for subtraction of drift and DC offset, and a post-subtraction high gain stage, enables detection of particles and cells as small as 1 μm in diameter, despite using a low-end 8-bit ADC. The lock-in-amplifier and the ADC were set up to receive and transmit data from a Bluetooth module. In order to initiate the system, as well as to transmit all of the data, a user friendly mobile application was developed, and a proof-of-concept trial was run on a blood sample. Applications such as personalized health monitoring require robust device operation and resilience to clogging. It is desirable to avoid using channels comparable in size to the particles being detected thus requiring high levels of sensitivity. Despite using low-end off-the-shelf hardware, our sensing platform was capable of detecting changes in impedance as small as 0.032%, allowing detection of 3 μm diameter particles in a 300 μm wide channel. The sensitivity of our system is comparable to that of a high-end bench-top impedance spectrometer when tested using the same sensors. The novel analog design allowed for an instrument with a footprint of less than 80 cm 2 . The aim of this work is to demonstrate the potential of using microfluidic impedance spectroscopy for low cost health monitoring. We demonstrated the utility of the platform technology towards cell counting, however, our platform is broadly applicable to assaying wide panels of biomarkers including proteins, nucleic acids, and various cell types.

  13. Cost-effective and low-technology options for simulation and training in neonatology.

    PubMed

    Bruno, Christie J; Glass, Kristen M

    2016-11-01

    The purpose of this review is to explore low-cost options for simulation and training in neonatology. Numerous cost-effective options exist for simulation and training in neonatology. Lower cost options are available for teaching clinical skills and procedural training in neonatal intubation, chest tube insertion, and pericardiocentesis, among others. Cost-effective, low-cost options for simulation-based education can be developed and shared in order to optimize the neonatal simulation training experience. Copyright © 2016 Elsevier Inc. All rights reserved.

  14. Low cost rubber seismic isolators for masonry housing in developing countries

    NASA Astrophysics Data System (ADS)

    Habieb, A. B.; Milani, G.; Tavio, Milani, F.

    2017-11-01

    Rubber isolators are used widely in constructions which require a vibration or seismic isolation. It consists of rubber layers and reinforcements that can be steel or fiber lamina. The fiber reinforced isolator results in a lower cost of production and application than that of steel. Using fiber reinforced isolator allows us to make an unbonded model of rubber bearing. This model leads to a smaller horizontal stiffness and larger displacement of isolators. Researchers consider the Unbonded Fiber Reinforced Elastomeric Isolator (U-FREI) as a low-cost form of rubber bearings. U-FREIs are suitable to isolate seismically a masonry building, which is a common type of housing in developing countries. In this work, we present a finite element model (FEM) to predict the behavior of the U-FREIs undergoing moderate deformations. We adopt a Yeoh hyperelasticity model which is available in the standard package of Abaqus FE software and estimate its coefficients through the available experimental data. Then, we apply that isolation system onto masonry housing with some simplified methods. We also observe the horizontal behaviors of U-FREIs under different vertical loads and consider a critical condition when the isolators start to be unstable. In parallel, we perform an analytical model to predict the shear behavior and the deformation limit of isolators. Finally, the results show that the analytical model is sufficiently accurate compared to the FE analyses.

  15. Prosthetic design directives: Low-cost hands within reach.

    PubMed

    Jones, G K; Rosendo, A; Stopforth, R

    2017-07-01

    Although three million people around the world suffer from the lack of one or both upper limbs 80% of this number is located within developing countries. While prosthetic prices soar with technology 3D printing and low cost electronics present a sensible solution for those that cannot afford expensive prosthetics. The electronic and control design of a low-cost prosthetic hand, the Touch Hand II, is discussed. This paper shows that sensorless techniques can be used to reduce design complexities, costs, and provide easier access to the electronics. A closing and opening finite state machine (COFSM) was developed to handle the actuated digit joint control state and a supervisory switching control scheme, used for speed and grip strength control. Three torque and speed settings were created to be preset for specific grasps. The hand was able to replicate ten frequently used grasps and grip some common objects. Future work is necessary to enable a user to control it with myoelectric signals (MESs) and to solve operational problems related to electromagnetic interference (EMI).

  16. Development of portable CdZnTe spectrometers for remote sensing of signatures from nuclear materials

    NASA Astrophysics Data System (ADS)

    Burger, Arnold; Groza, Michael; Cui, Yunlong; Roy, Utpal N.; Hillman, Damian; Guo, Mike; Li, Longxia; Wright, Gomez W.; James, Ralph B.

    2005-03-01

    Room temperature cadmium zinc telluride (CZT) gamma-ray spectrometers are being developed for a number for years for medical, space and national security applications where high sensitivity, low operating power and compactness are indispensable. The technology has matured now to the point where large volume (several cubic centimeters) and high energy resolution (approximately 1% at 660 eV) of gamma photons, are becoming available for their incorporation into portable systems for remote sensing of signatures from nuclear materials. The straightforward approach of utilizing a planar CZT device has been excluded due to the incomplete collection arising from the trapping of holes and causing broadening of spectral lines at energies above 80 keV, to unacceptable levels of performance. Solutions are being pursued by developing devices aimed at processing the signal produced primarily by electrons and practically insensitive to the contribution of holes, and recent progress has been made in the areas of material growth as well as electrode and electronics design. Present materials challenges are in the growth of CZT boules from which large, oriented single crystal pieces can be cut to fabricate such sizable detectors. Since virtually all the detector grade CZT boules consist of several grains, the cost of a large, single crystal section is still high. Co-planar detectors, capacitive Frisch-grid detectors and devices taking advantage of the small pixel effect, are configurations with a range of requirements in crystallinity and defect content and involve variable degrees of complexity in the fabrication, surface passivation and signal processing. These devices have been demonstrated by several research groups and will be discussed in terms of their sensitivity and availability.

  17. Estimating Suicide Rates in Developing Nations: A Low-Cost Newspaper Capture-Recapture Approach in Cambodia.

    PubMed

    Harris, Keith M; Thandrayen, Joanne; Samphoas, Chien; Se, Pros; Lewchalermwongse, Boontriga; Ratanashevorn, Rattanakorn; Perry, Megan L; Britts, Choloe

    2016-04-01

    This study tested a low-cost method for estimating suicide rates in developing nations that lack adequate statistics. Data comprised reported suicides from Cambodia's 2 largest newspapers. Capture-recapture modeling estimated a suicide rate of 3.8/100 000 (95% CI = 2.5-6.7) for 2012. That compares to World Health Organization estimates of 1.3 to 9.4/100 000 and a Cambodian government estimate of 3.5/100 000. Suicide rates of males were twice that of females, and rates of those <40 years were twice that of those ≥40 years. Capture-recapture modeling with newspaper reports proved a reasonable method for estimating suicide rates for countries with inadequate official data. These methods are low-cost and can be applied to regions with at least 2 newspapers with overlapping reports. Means to further improve this approach are discussed. These methods are applicable to both recent and historical data, which can benefit epidemiological work, and may also be applicable to homicides and other statistics. © 2016 APJPH.

  18. Development, acceptability, and nutritional characteristics of a low-cost, shelf-stable supplementary food product for vulnerable groups in Kenya.

    PubMed

    Kunyanga, Catherine; Imungi, Jasper; Okoth, Michael; Vadivel, Vellingiri; Biesalski, Hans Konrad

    2012-03-01

    Food-based approaches have been advocated as the best strategies to curb hunger and malnutrition in developing countries. The use of low-cost, locally available, nutritious foods in the development of supplementary foods has been recommended. To develop low-cost food supplements using different traditionally processed local foods, consisting of cereals, legumes, nuts, fish, and vegetables, to meet the nutrient requirements for vulnerable groups in Kenya. Four food supplements were developed and evaluated by taste panel procedures. The product containing amaranth grain, pigeon pea, sweet potato, groundnuts, and brown sugar was found to be the most acceptable supplement. Evaluation of nutritional composition, shelf-life, and cost analysis of the acceptable supplement was carried out to assess if it could satisfactorily provide more than 50% of the Recommended Dietary Allowances (RDAs) of the basic nutrients for vulnerable groups. The acceptable supplement contained 453.2 kcal energy, 12.7 g crude protein, 54.3 g soluble carbohydrates, 20.8 g crude fat, and 10.1 g crude fiber per 110 g. The micronutrient contents were 93.0 mg calcium, 172.4 mg magnesium, 2.7 mg zinc, 5.7 mg iron, 0.8 mg vitamin B₁, 0.2 mg vitamin B₂, 7.9 mg niacin, 100 microg folic acid, and 140 microg retinol equivalent per 110 g. The supplement also contained 21% total essential amino acid in addition to appreciable levels of palmitic, stearic, oleic, linoleic, and alpha-linolenic fatty acids. The shelf-life study showed that it could be stored in different packaging materials (polythene bags, gunny bags, and kraft paper) at 26°C without deleterious effects on its chemical composition for up to 4 months. Cost analysis of the supplement indicated that the product could be competitively sold at US$0.812/kg (KES 65.50/kg). Locally available indigenous foods can be used in the formulation of acceptable, low-cost, shelf-stable, nutritious supplementary foods for vulnerable groups.

  19. Development of a low-cost, modified resin transfer molding process using elastomeric tooling and automated preform fabrication

    NASA Technical Reports Server (NTRS)

    Doane, William J.; Hall, Ronald G.

    1992-01-01

    This paper describes the design and process development of low-cost structural parts made by a modified resin transfer molding process. Innovative application of elastomeric tooling to increase laminate fiber volume and automated forming of fiber preforms are discussed, as applied to fabrication of a representative section of a cruise missile fuselage.

  20. Data processing workflows from low-cost digital survey to various applications: three case studies of Chinese historic architecture

    NASA Astrophysics Data System (ADS)

    Sun, Z.; Cao, Y. K.

    2015-08-01

    The paper focuses on the versatility of data processing workflows ranging from BIM-based survey to structural analysis and reverse modeling. In China nowadays, a large number of historic architecture are in need of restoration, reinforcement and renovation. But the architects are not prepared for the conversion from the booming AEC industry to architectural preservation. As surveyors working with architects in such projects, we have to develop efficient low-cost digital survey workflow robust to various types of architecture, and to process the captured data for architects. Although laser scanning yields high accuracy in architectural heritage documentation and the workflow is quite straightforward, the cost and portability hinder it from being used in projects where budget and efficiency are of prime concern. We integrate Structure from Motion techniques with UAV and total station in data acquisition. The captured data is processed for various purposes illustrated with three case studies: the first one is as-built BIM for a historic building based on registered point clouds according to Ground Control Points; The second one concerns structural analysis for a damaged bridge using Finite Element Analysis software; The last one relates to parametric automated feature extraction from captured point clouds for reverse modeling and fabrication.

  1. Low-cost fluorescence microscopy for point-of-care cell imaging

    NASA Astrophysics Data System (ADS)

    Lochhead, Michael J.; Ives, Jeff; Givens, Monique; Delaney, Marie; Moll, Kevin; Myatt, Christopher J.

    2010-02-01

    Fluorescence microscopy has long been a standard tool in laboratory medicine. Implementation of fluorescence microscopy for near-patient diagnostics, however, has been limited due to cost and complexity associated with traditional fluorescence microscopy techniques. There is a particular need for robust, low-cost imaging in high disease burden areas in the developing world, where access to central laboratory facilities and trained staff is limited. Here we describe a point-of-care assay that combines a disposable plastic cartridge with an extremely low cost fluorescence imaging instrument. Based on a novel, multi-mode planar waveguide configuration, the system capitalizes on advances in volume-manufactured consumer electronic components to deliver an imaging system with minimal moving parts and low power requirements. A two-color cell imager is presented, with magnification optimized for enumeration of immunostained human T cells. To demonstrate the system, peripheral blood mononuclear cells were stained with fluorescently labeled anti-human-CD4 and anti-human-CD3 antibodies. Registered images were used to generate fractional CD4+ and CD3+ staining and enumeration results that show excellent correlation with flow cytometry. The cell imager is under development as a very low cost CD4+ T cell counter for HIV disease management in limited resource settings.

  2. A Portable, High Resolution, Surface Measurement Device

    NASA Technical Reports Server (NTRS)

    Ihlefeld, Curtis M.; Burns, Bradley M.; Youngquist, Robert C.

    2012-01-01

    A high resolution, portable, surface measurement device has been demonstrated to provide micron-resolution topographical plots. This device was specifically developed to allow in-situ measurements of defects on the Space Shuttle Orbiter windows, but is versatile enough to be used on a wide variety of surfaces. This paper discusses the choice of an optical sensor and then the decisions required to convert a lab bench optical measurement device into an ergonomic portable system. The necessary trade-offs between performance and portability are presented along with a description of the device developed to measure Orbiter window defects.

  3. Situational Awareness from a Low-Cost Camera System

    NASA Technical Reports Server (NTRS)

    Freudinger, Lawrence C.; Ward, David; Lesage, John

    2010-01-01

    A method gathers scene information from a low-cost camera system. Existing surveillance systems using sufficient cameras for continuous coverage of a large field necessarily generate enormous amounts of raw data. Digitizing and channeling that data to a central computer and processing it in real time is difficult when using low-cost, commercially available components. A newly developed system is located on a combined power and data wire to form a string-of-lights camera system. Each camera is accessible through this network interface using standard TCP/IP networking protocols. The cameras more closely resemble cell-phone cameras than traditional security camera systems. Processing capabilities are built directly onto the camera backplane, which helps maintain a low cost. The low power requirements of each camera allow the creation of a single imaging system comprising over 100 cameras. Each camera has built-in processing capabilities to detect events and cooperatively share this information with neighboring cameras. The location of the event is reported to the host computer in Cartesian coordinates computed from data correlation across multiple cameras. In this way, events in the field of view can present low-bandwidth information to the host rather than high-bandwidth bitmap data constantly being generated by the cameras. This approach offers greater flexibility than conventional systems, without compromising performance through using many small, low-cost cameras with overlapping fields of view. This means significant increased viewing without ignoring surveillance areas, which can occur when pan, tilt, and zoom cameras look away. Additionally, due to the sharing of a single cable for power and data, the installation costs are lower. The technology is targeted toward 3D scene extraction and automatic target tracking for military and commercial applications. Security systems and environmental/ vehicular monitoring systems are also potential applications.

  4. Multi-Site Simultaneous Time-Resolved Photometry with a Low Cost Electro-Optics System †

    PubMed Central

    Gasdia, Forrest; Barjatya, Aroh; Bilardi, Sergei

    2017-01-01

    Sunlight reflected off of resident space objects can be used as an optical signal for astrometric orbit determination and for deducing geometric information about the object. With the increasing population of small satellites and debris in low Earth orbit, photometry is a powerful tool in operational support of space missions, whether for anomaly resolution or object identification. To accurately determine size, shape, spin rate, status of deployables, or attitude information of an unresolved resident space object, multi-hertz sample rate photometry is required to capture the relatively rapid changes in brightness that these objects can exhibit. OSCOM, which stands for Optical tracking and Spectral characterization of CubeSats for Operational Missions, is a low cost and portable telescope system capable of time-resolved small satellite photometry, and is field deployable on short notice for simultaneous observation from multiple sites. We present the electro-optical design principles behind OSCOM and light curves of the 1.5 U DICE-2 CubeSat and simultaneous observations of the main body of the ASTRO-H satellite after its fragmentation event. PMID:28556802

  5. High-precision and low-cost vibration generator for low-frequency calibration system

    NASA Astrophysics Data System (ADS)

    Li, Rui-Jun; Lei, Ying-Jun; Zhang, Lian-Sheng; Chang, Zhen-Xin; Fan, Kuang-Chao; Cheng, Zhen-Ying; Hu, Peng-Hao

    2018-03-01

    Low-frequency vibration is one of the harmful factors that affect the accuracy of micro-/nano-measuring machines because its amplitude is significantly small and it is very difficult to avoid. In this paper, a low-cost and high-precision vibration generator was developed to calibrate an optical accelerometer, which is self-designed to detect low-frequency vibration. A piezoelectric actuator is used as vibration exciter, a leaf spring made of beryllium copper is used as an elastic component, and a high-resolution, low-thermal-drift eddy current sensor is applied to investigate the vibrator’s performance. Experimental results demonstrate that the vibration generator can achieve steady output displacement with frequency range from 0.6 Hz to 50 Hz, an analytical displacement resolution of 3.1 nm and an acceleration range from 3.72 mm s-2 to 1935.41 mm s-2 with a relative standard deviation less than 1.79%. The effectiveness of the high-precision and low-cost vibration generator was verified by calibrating our optical accelerometer.

  6. Development of low cost fabrication techniques for large solid rocket nozzles

    NASA Technical Reports Server (NTRS)

    Warga, J. J.

    1971-01-01

    Property measurements and fabrication characteristics were determined and the performance in subscale (Minuteman Wing 2 second stage) motors was evaluated. It was demonstrated that the incorporation of low cost fabrication techniques in a full scale 260 in. nozzle could result in savings of $149,000 when compared with an identical design using tape-wrapped components throughout.

  7. Design of portable electrocardiogram device using DSO138

    NASA Astrophysics Data System (ADS)

    Abuzairi, Tomy; Matondang, Josef Stevanus; Purnamaningsih, Retno Wigajatri; Basari, Ratnasari, Anita

    2018-02-01

    Cardiovascular disease has been one of the leading causes of sudden cardiac deaths in many countries, covering Indonesia. Electrocardiogram (ECG) is a medical test to detect cardiac abnormalities by measuring the electrical activity generated by the heart, as the heart contracts. By using ECG, we can observe anomaly at the time of heart abnormalities. In this paper, design of portable ECG device is presented. The portable ECG device was designed to easily use in the village clinic or houses, due to the small size device and other benefits. The device was designed by using four units: (1) ECG electrode; (2) ECG analog front-end; (3) DSO138; and (4) battery. To create a simple electrode system in the portable ECG, 1-lead ECG with two electrodes were applied. The analog front-end circuitry consists of three integrated circuits, an instrumentation amplifier AD820AN, a low noise operational amplifier OPA134, and a low offset operational amplifier TL082. Digital ECG data were transformed to graphical data on DSO138. The results show that the portable ECG is successfully read the signal from 1-lead ECG system.

  8. Low cost omega navigation receiver

    NASA Technical Reports Server (NTRS)

    Lilley, R. W.

    1974-01-01

    The development of a low cost Omega navigation receiver is discussed. Emphasis is placed on the completion and testing of a modular, multipurpose Omega receiver which utilizes a digital memory-aided, phase-locked loop to provide phase measurement data to a variety of applications interfaces. The functional units contained in the prototype device are described. The receiver is capable of receiving and storing phase measurements for up to eight Omega signals and computes two switch-selectable lines of position, displaying this navigation data in chart-recorded form.

  9. Portable and Mobile Classroom (PortMoC)

    ERIC Educational Resources Information Center

    Gerraughty, James F.

    2004-01-01

    The Portable and Mobile Classroom (PortMoC) began as an idea to bring Internet connectivity to places where there was no connectivity for education and healthcare, but still make the connection reasonably sustainable in terms of cost and manpower. Through trial and error and several research iterations, Saint Francis University's Center of…

  10. Design and Development of Low-Cost Water Tunnel for Educational Purpose

    NASA Astrophysics Data System (ADS)

    Zahari, M.; Dol, S. S.

    2015-04-01

    The hydrodynamic behaviour of immersed body is essential in fluid dynamics study. Water tunnel is an example of facility required to provide a controlled condition for fluid flow research. The operational principle of water tunnel is quite similar to the wind tunnel but with different working fluid and higher flow-pumping capacity. Flow visualization in wind tunnel is more difficult to conduct as turbulent flows in wind dissipate quickly whilst water tunnel is more suitable for such purpose due to higher fluid viscosity and wide variety of visualization techniques can be employed. The present work focusses on the design and development of open flow water tunnel for the purpose of studying vortex-induced vibration from turbulent vortex shedding phenomenon. The water tunnel is designed to provide a steady and uniform flow speed within the test section area. Construction details are discussed for development of low-cost water tunnel for quantitative and qualitative fluid flow measurements. The water tunnel can also be used for educational purpose such as fluid dynamics class activity to provide quick access to visualization medium for better understanding of various turbulence motion learnt in class.

  11. Low Cost Structures, but How Much are we Paying for Them?

    NASA Astrophysics Data System (ADS)

    Gomez Molinero, Vincent

    2014-06-01

    Based on more than 37 years developing spacecraft structures - both for launchers starting with Ariane-1 up to the most modern ones and for satellites of any type - a critical review of the current trends, aiming specially to low cost solutions, will be presented.Airbus Defence and Space (CASA Espacio previously) has been developing structures for launchers and satellites during more than 4 decades. All types of spacecraft structures - primary and secondary ones, high stability ones and special critical cases like antenna reflectors, high stiffness structures and load carrying ones - have been developed using different types of materials and structural constructions. Although our main expertise is concentrated on composite structures, we have also developed many types of metallic ones, when the best solution was that one, not necessarily only based on pure technical reasons.From that perspective and experience, this paper tries to review the current trend of imposing the low cost as the main requirement for the development of satellites and launchers and its intrinsic characteristic of being a non- ending process: the spacecraft structures are never sufficiently cheaper.The main ways used today to justify low cost spacecraft structures will be reviewed trying to understand their rationale and some prejudices always present when the trade-off studies are performed. Some of the reviewed cost-killing factors will be (non-exhaustive list) Material type (i.e.: metallic vs composite). Low cost materials in general. Manufacturing process (i.e.: autoclave curing vs out-of-autoclave one). Automation in manufacturing. Automation in assembly. Automation in inspection and verification. Lean manufacturing techniques. Standardization. Some insight about how to solve this problem without losing our distinctive nature (we are developing high performance systems many of them unique prototypes and thought to work in environments not perfectly known and highly unknown in some cases

  12. Disposable cartridge biosensor platform for portable diagnostics

    NASA Astrophysics Data System (ADS)

    Yaras, Yusuf S.; Cakmak, Onur; Gunduz, Ali B.; Saglam, Gokhan; Olcer, Selim; Mostafazadeh, Aref; Baris, Ibrahim; Civitci, Fehmi; Yaralioglu, Goksen G.; Urey, Hakan

    2017-03-01

    We developed two types of cantilever-based biosensors for portable diagnostics applications. One sensor is based on MEMS cantilever chip mounted in a microfluidic channel and the other sensor is based on a movable optical fiber placed across a microfluidic channel. Both types of sensors were aimed at direct mechanical measurement of coagulation time in a disposable cartridge using plasma or whole blood samples. There are several similarities and also some important differences between the MEMS based and the optical fiber based solutions. The aim of this paper is to provide a comparison between the two solutions and the results. For both types of sensors, actuation of the cantilever or the moving fiber is achieved using an electro coil and the readout is optical. Since both the actuation and sensing are remote, no electrical connections are required for the cartridge. Therefore it is possible to build low cost disposable cartridges. The reader unit for the cartridge contains light sources, photodetectors, the electro coil, a heater, analog electronics, and a microprocessor. The reader unit has different optical interfaces for the cartridges that have MEMS cantilevers and moving fibers. MEMS based platform has better sensitivity but optomechanical alignment is a challenge and measurements with whole blood were not possible due to high scattering of light by the red blood cells. Fiber sensor based platform has relaxed optomechanical tolerances, ease of manufacturing, and it allows measurements in whole blood. Both sensors were tested using control plasma samples for activated-Partial-Thromboplastin-Time (aPTT) measurements. Control plasma test results matched with the manufacturer's datasheet. Optical fiber based system was tested for aPTT tests with human whole blood samples and the proposed platform provided repeatable test results making the system method of choice for portable diagnostics.

  13. Alloy Corrosion Considerations in Low-Cost, Clean Biomass Cookstoves for the Developing World

    DOE PAGES

    Brady, Michael P.; Banta, Kelly; Mizia, John; ...

    2017-04-01

    In nearly 40% of the world cooks on open fires or inefficient biomass-fueled cookstoves. The resulting smoke is a health hazard, contributing to an estimated 4 million premature deaths per year, as well as a major source of black carbon emissions. One solution is the introduction of improved, clean-burning biomass cookstoves. One of the most challenging components is the combustor, which must operate at high temperatures (often ≥ 600 °C) in the presence of highly corrosive species released from biomass fuel combustion, yet be sufficiently low cost to permit widespread adoption. In our present work we report the development ofmore » accelerated corrosion test screening protocols employing highly corrosive salt and water vapor species, specifically designed to evaluate alloys for clean biomass cookstove combustors, and corrosion findings for a range of commercial and developmental alloys. Lastly, a new Fe-Cr-Si base alloy that offers promise for improved corrosion resistance at lower cost than state-of the art FeCrAl and stainless steel alloys is also reported.« less

  14. Alloy Corrosion Considerations in Low-Cost, Clean Biomass Cookstoves for the Developing World

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brady, Michael P.; Banta, Kelly; Mizia, John

    In nearly 40% of the world cooks on open fires or inefficient biomass-fueled cookstoves. The resulting smoke is a health hazard, contributing to an estimated 4 million premature deaths per year, as well as a major source of black carbon emissions. One solution is the introduction of improved, clean-burning biomass cookstoves. One of the most challenging components is the combustor, which must operate at high temperatures (often ≥ 600 °C) in the presence of highly corrosive species released from biomass fuel combustion, yet be sufficiently low cost to permit widespread adoption. In our present work we report the development ofmore » accelerated corrosion test screening protocols employing highly corrosive salt and water vapor species, specifically designed to evaluate alloys for clean biomass cookstove combustors, and corrosion findings for a range of commercial and developmental alloys. Lastly, a new Fe-Cr-Si base alloy that offers promise for improved corrosion resistance at lower cost than state-of the art FeCrAl and stainless steel alloys is also reported.« less

  15. Who Purchases Low-Cost Alcohol in Australia?

    PubMed

    Callinan, Sarah; Room, Robin; Livingston, Michael; Jiang, Heng

    2015-11-01

    Debates surrounding potential price-based polices aimed at reducing alcohol-related harms tend to focus on the debate concerning who would be most affected-harmful or low-income drinkers. This study will investigate the characteristics of people who purchase low-cost alcohol using data from the Australian arm of the International Alcohol Control study. 1681 Australians aged 16 and over who had consumed alcohol and purchased it in off-licence premises were asked detailed questions about both practices. Low-cost alcohol was defined using cut-points of 80¢, $1.00 or $1.25 per Australian standard drink. With a $1.00 cut-off low income (OR = 2.1) and heavy drinkers (OR = 1.7) were more likely to purchase any low-cost alcohol. Harmful drinkers purchased more, and low-income drinkers less, alcohol priced at less than $1.00 per drink than high income and moderate drinkers respectively. The relationship between the proportion of units purchased at low cost and both drinker category and income is less clear, with hazardous, but not harmful, drinkers purchasing a lower proportion of units at low cost than moderate drinkers. The impact of minimum pricing on low income and harmful drinkers will depend on whether the proportion or total quantity of all alcohol purchased at low cost is considered. Based on absolute units of alcohol, minimum unit pricing could be differentially effective for heavier drinkers compared to other drinkers, particularly for young males. © The Author 2015. Medical Council on Alcohol and Oxford University Press. All rights reserved.

  16. Portable thin layer chromatography for field detection of explosives and propellants

    NASA Astrophysics Data System (ADS)

    Satcher, Joe H.; Maienschein, Jon L.; Pagoria, Philip F.; Racoveanu, Ana; Carman, M. Leslie; Whipple, Richard E.; Reynolds, John G.

    2012-06-01

    A field deployable detection kit for explosives and propellants using thin layer chromatography (TLC) has been developed at Lawrence Livermore National Laboratory (LLNL). The chemistry of the kit has been modified to allow for field detection of propellants (through propellant stabilizers), military explosives, peroxide explosives, nitrates and inorganic oxidizer precursors. For many of these target analytes, the detection limit is in the μg to pg range. A new miniaturized, bench prototype, field portable TLC (Micro TLC) kit has also been developed for the detection and identification of common military explosives. It has been demonstrated in a laboratory environment and is ready for field-testing. The kit is comprised of a low cost set of commercially available components specifically assembled for rapid identification needed in the field and identifies the common military explosives: HMX, RDX, Tetryl, Explosive D or picric acid, and TNT all on one plate. Additional modifications of the Micro TLC system have been made with fluorescent organosilicon co-polymer coatings to detect a large suite of explosives.

  17. Development of a simple and low cost microbioreactor for high-throughput bioprocessing.

    PubMed

    Rahman, Pattanathu K S M; Pasirayi, Godfrey; Auger, Vincent; Ali, Zulfiqur

    2009-02-01

    A simple microbioreactor for high-throughput bioprocessing made from low cost polymer polytetrafluoroethylene (PTFE) tubes with a working volume of 1.5 ml is described. We have developed a microfluidic system that handles a small population of cells of a model microorganism, Pseudomonas aeruginosa DS10-129. Under the conditions of the microbioreactor, the organism produced extracellular secondary metabolites by using nutrient broth modified with glycerol. Pyocyanins were isolated from the fermented medium as a metabolite of interest. Antibiotic properties of pyocyanin were effective against a number of microorganisms such as Staphylococcus aureus, S. epidermis, Bacillus subtilis, Micrococcus luteus and Saccharomyces cerevisiae. Batch fermentation of the model organism in the microbioreactor was compared to shake-flask and conventional bench fermenter methods. Results obtained from the microbioreactor compared favourably with the conventional processes.

  18. A review of the development of portable laser induced breakdown spectroscopy and its applications

    NASA Astrophysics Data System (ADS)

    Rakovský, J.; Čermák, P.; Musset, O.; Veis, P.

    2014-11-01

    In this review, we present person-transportable laser induced breakdown spectroscopy (LIBS) devices that have previously been developed and reported in the literature as well as their applications. They are compared with X-ray fluorescent (XRF) devices, which represent their strongest competition. Although LIBS devices have advantages over XRF devices, such as sensitivity to the light elements, high spatial resolution and the possibility to distinguish between different layers of the sample, there are also disadvantages and both are discussed here. Furthermore, the essential portable LIBS instrumentation (laser, spectrograph and detector) is presented, and published results related to new laser sources (diode-pumped solid-state, microchip and fiber lasers) used in LIBS are overviewed. Compared to conventional compact flashlamp pumped solid-state lasers, the new laser sources provide higher repetition rates, higher efficiency (less power consumption) and higher beam quality, resulting in higher fluences, even for lower energies, and could potentially increase the figure of merit of portable LIBS instruments. Compact spectrometers used in portable LIBS devices and their parts (spectrograph, detector) are also discussed.

  19. PEM Electrolyzer Incorporating an Advanced Low-Cost Membrane

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hamdan, Monjid

    The Department of Energy (DOE) has identified hydrogen production by electrolysis of water at forecourt stations as a critical technology for transition to the hydrogen economy; however, the cost of hydrogen produced by present commercially available electrolysis systems is considerably higher than the DOE 2015 and 2020 cost targets. Analyses of proton-exchange membrane (PEM) electrolyzer systems indicate that reductions in electricity consumption and electrolyzer stack and system capital cost are required to meet the DOE cost targets. The primary objective is to develop and demonstrate a cost-effective energy-based system for electrolytic generation of hydrogen. The goal is to increase PEMmore » electrolyzer efficiency and to reduce electrolyzer stack and system capital cost to meet the DOE cost targets for distributed electrolysis. To accomplish this objective, work was conducted by a team consisting of Giner, Inc. (Giner), Virginia Polytechnic Institute & University (VT), and domnick hunter group, a subsidiary of Parker Hannifin (Parker). The project focused on four (4) key areas: (1) development of a high-efficiency, high-strength membrane; (2) development of a long-life cell-separator; (3) scale-up of cell active area to 290 cm2 (from 160 cm²); and (4) development of a prototype commercial electrolyzer system. In each of the key stack development areas Giner and our team members conducted focused development in laboratory-scale hardware, with analytical support as necessary, followed by life-testing of the most promising candidate materials. Selected components were then scaled up and incorporated into low-cost scaled-up stack hardware. The project culminated in the fabrication and testing of a highly efficient electrolyzer system for production of 0.5 kg/hr hydrogen and validation of the stack and system in testing at the National Renewable Energy Laboratory (NREL).« less

  20. Neurogaming Technology Meets Neuroscience Education: A Cost-Effective, Scalable, and Highly Portable Undergraduate Teaching Laboratory for Neuroscience

    PubMed Central

    de Wit, Bianca; Badcock, Nicholas A.; Grootswagers, Tijl; Hardwick, Katherine; Teichmann, Lina; Wehrman, Jordan; Williams, Mark; Kaplan, David Michael

    2017-01-01

    Active research-driven approaches that successfully incorporate new technology are known to catalyze student learning. Yet achieving these objectives in neuroscience education is especially challenging due to the prohibitive costs and technical demands of research-grade equipment. Here we describe a method that circumvents these factors by leveraging consumer EEG-based neurogaming technology to create an affordable, scalable, and highly portable teaching laboratory for undergraduate courses in neuroscience. This laboratory is designed to give students hands-on research experience, consolidate their understanding of key neuroscience concepts, and provide a unique real-time window into the working brain. Survey results demonstrate that students found the lab sessions engaging. Students also reported the labs enhanced their knowledge about EEG, their course material, and neuroscience research in general. PMID:28690430

  1. Improving Short Term Instability for Quantitative Analyses with Portable Electronic Noses

    PubMed Central

    Macías, Miguel Macías; Agudo, J. Enrique; Manso, Antonio García; Orellana, Carlos Javier García; Velasco, Horacio Manuel González; Caballero, Ramón Gallardo

    2014-01-01

    One of the main problems when working with electronic noses is the lack of reproducibility or repeatability of the sensor response, so that, if this problem is not properly considered, electronic noses can be useless, especially for quantitative analyses. On the other hand, irreproducibility is increased with portable and low cost electronic noses where laboratory equipment like gas zero generators cannot be used. In this work, we study the reproducibility of two portable electronic noses, the PEN3 (commercial) and CAPINose (a proprietary design) by using synthetic wine samples. We show that in both cases short term instability associated to the sensors' response to the same sample and under the same conditions represents a major problem and we propose an internal normalization technique that, in both cases, reduces the variability of the sensors' response. Finally, we show that the normalization proposed seems to be more effective in the CAPINose case, reducing, for example, the variability associated to the TGS2602 sensor from 12.19% to 2.2%. PMID:24932869

  2. PePSS - A portable sky scanner for measuring extremely low night-sky brightness

    NASA Astrophysics Data System (ADS)

    Kocifaj, Miroslav; Kómar, Ladislav; Kundracik, František

    2018-05-01

    A new portable sky scanner designed for low-light-level detection at night is developed and employed in night sky brightness measurements in a rural region. The fast readout, adjustable sensitivity and linear response guaranteed in 5-6 orders of magnitude makes the device well suited for narrow-band photometry in both dark areas and bright urban and suburban environments. Quasi-monochromatic night-sky brightness data are advantageous in the accurate characterization of spectral power distribution of scattered and emitted light and, also allows for the possibility to retrieve light output patterns from whole-city light sources. The sky scanner can operate in both night and day regimes, taking advantage of the complementarity of both radiance data types. Due to its inherent very high sensitivity the photomultiplier tube could be used in night sky radiometry, while the spectrometer-equipped system component capable of detecting elevated intensities is used in daylight monitoring. Daylight is a source of information on atmospheric optical properties that in turn are necessary in processing night sky radiances. We believe that the sky scanner has the potential to revolutionize night-sky monitoring systems.

  3. Managing Geothermal Exploratory Drilling Risks Drilling Geothermal Exploration and Delineation Wells with Small-Footprint Highly Portable Diamond Core Drills

    NASA Astrophysics Data System (ADS)

    Tuttle, J.; Listi, R.; Combs, J.; Welch, V.; Reilly, S.

    2012-12-01

    Small hydraulic core rigs are highly portable (truck or scow-mounted), and have recently been used for geothermal exploration in areas such as Nevada, California, the Caribbean Islands, Central and South America and elsewhere. Drilling with slim diameter core rod below 7,000' is common, with continuous core recovery providing native-state geological information to aid in identifying the resource characteristics and boundaries; this is a highly cost-effective process. Benefits associated with this innovative exploration and delineation technology includes the following: Low initial Capital Equipment Cost and consumables costs Small Footprint, reducing location and road construction, and cleanup costs Supporting drill rod (10'/3meter) and tools are relatively low weight and easily shipped Speed of Mobilization and rig up Reduced requirements for support equipment (cranes, backhoes, personnel, etc) Small mud systems and cementing requirements Continuous, simplified coring capability Depth ratings comparable to that of large rotary rigs (up to ~10,000'+) Remote/small-location accessible (flown into remote areas or shipped in overseas containers) Can be scow or truck-mounted This technical presentation's primary goal is to share the technology of utilizing small, highly portable hydraulic coring rigs to provide exploratory drilling (and in some cases, production drilling) for geothermal projects. Significant cost and operational benefits are possible for the Geothermal Operator, especially for those who are pursuing projects in remote locations or countries, or in areas that are either inaccessible or in which a small footprint is required. John D. Tuttle Sinclair Well Products jtuttle@sinclairwp.com

  4. Lab-on-a-Chip Application Development-Portable Test System (LOCAD) Phase 2

    NASA Image and Video Library

    2009-03-21

    ISS018-E-041370 (21 March 2009) --- Astronaut Sandra Magnus, STS-119 mission specialist, prepares to work with the Lab-on-a-Chip Application Development-Portable Test System (LOCAD-PTS) experiment in the Destiny laboratory while Space Shuttle Discovery remains docked with the International Space Station. LOCAD-PTS is a handheld device for rapid detection of biological and chemical substances onboard the station.

  5. Developments toward a Low-Cost Approach for Long-Term, Unattended Vapor Intrusion Monitoring

    PubMed Central

    Tolley, William K.

    2014-01-01

    There are over 450,000 sites contaminated by chemicals in the US. This large number of contaminated sites and the speed of subsurface migration of chemicals pose considerable risk to nearby residences and commercial buildings. The high costs for monitoring around these site stem from the labor involved in placing and replacing the passive sorbent vapor samplers and the resultant laboratory analysis. This monitoring produces sparse data sets that do not track temporal changes well. To substantially reduce costs and better track exposures, less costly, unattended systems for monitoring soil gases and vapor intrusion into homes and businesses are desirable to aid in the remediation of contaminated sites. This paper describes progress toward the development of an inexpensive system specifically for monitoring vapor intrusion; the system can operate repeatedly without user intervention with low detection limits (1 × 10−9, or 1 part-per-billion). Targeted analytes include chlorinated hydrocarbons (dichloroethylene, trichloroethane, trichloroethylene, and perchloroethylene) and benzene. The system consists of a trap-and-purge preconcentrator for vapor collection in conjunction with a compact gas chromatography instrument to separate individual compounds. Chemical detection is accomplished with an array of chemicapacitors and a metal-oxide semiconductor combustibles sensor. Both the preconcentrator and the chromatography column are resistively heated. All components are compatible with ambient air, which serves as the carrier gas for the gas chromatography and detectors. PMID:24903107

  6. CAIRSENSE Study: Real-world evaluation of low cost sensors in Denver, Colorado

    EPA Science Inventory

    Low-cost air pollution sensors are a rapidly developing field in air monitoring. In recent years, numerous sensors have been developed that can provide real-time concentration data for different air pollutants at costs accessible to individuals and non-regulatory groups. Addition...

  7. POINTER: Portable Intelligent Trainer for External Robotics

    NASA Technical Reports Server (NTRS)

    Kuiper, Hilbert; Rikken, Patrick J.

    1994-01-01

    Intelligent tutoring systems (ITS's) play an increasing role in training and education of people with different levels of skill and knowledge. As compared to conventional computer based training (CBT) an ITS provides more tailored instruction by trying to mimic the teaching behavior of a human instructor as much as possible and is therefore much more flexible. This paper starts with an introduction to ITS's, followed by the description of an ITS for training of an (astronaut) operator in monitoring and controlling robotic arm procedures. The robotic arm will be used for exchange of equipment between a space station and a space plane involving critical and accurate movements of the robotic arm. The ITS for this application, called Pointer, is developed by TNO Physics and Electronics Laboratory and is based upon an existing ITS that includes procedural training. Pointer has been developed on a workstation whereas the target platform was a portable computer. Therefore, a lot of attention had to be paid to scaling effects and keeping up with user friendliness of the much smaller user interface. Although the learning domain was the control of a robotic arm, it is clear that use of intelligent training technologies on a portable computer has many other applications (payload operations, operation control rooms, etc.). Training can occur at any time and place in an attractive and cost effective way.

  8. Development test results of the Portable, Reconfigurable Sky Sensor (PRSS)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Blattman, D.A.

    1993-12-31

    The protection of assets against surreptitious access from the sky is a continuing problem. The Portable, Reconfigurable Sky Sensor is designed to provide volumetric intruder detection against low-observable aircraft, helicopters, and parachutists in the sky. Multiple systems may be joined to form continuous detection volume for applications such as borders. The PRSS is resistant to nuisance alarms due to wind up to 70 mph, rain/snow up to 6 inches/hour or small targets such as birds. The PRSS has been successfully tested against multiple intrusions with altitude range from 50 to 3,000 feet and cross-range up to 3,000 feet. This papermore » summarizes some of these field tests and lists specifications and potential uses.« less

  9. Low-Cost Aqueous Coal Desulfurization

    NASA Technical Reports Server (NTRS)

    Kalvinskas, J. J.; Vasilakos, N.; Corcoran, W. H.; Grohmann, K.; Rohatgi, N. K.

    1982-01-01

    Water-based process for desulfurizing coal not only eliminates need for costly organic solvent but removes sulfur more effectively than an earlier solvent-based process. New process could provide low-cost commercial method for converting high-sulfur coal into environmentally acceptable fuel.

  10. Portable brine evaporator unit, process, and system

    DOEpatents

    Hart, Paul John; Miller, Bruce G.; Wincek, Ronald T.; Decker, Glenn E.; Johnson, David K.

    2009-04-07

    The present invention discloses a comprehensive, efficient, and cost effective portable evaporator unit, method, and system for the treatment of brine. The evaporator unit, method, and system require a pretreatment process that removes heavy metals, crude oil, and other contaminates in preparation for the evaporator unit. The pretreatment and the evaporator unit, method, and system process metals and brine at the site where they are generated (the well site). Thus, saving significant money to producers who can avoid present and future increases in transportation costs.

  11. Design and Development of an Equipotential Voltage Reference (Grounding) System for a Low-Cost Rapid-Development Modular Spacecraft Architecture

    NASA Technical Reports Server (NTRS)

    Lukash, James A.; Daley, Earl

    2011-01-01

    This work describes the design and development effort to adapt rapid-development space hardware by creating a ground system using solutions of low complexity, mass, & cost. The Lunar Atmosphere and Dust Environment Explorer (LADEE) spacecraft is based on the modular common spacecraft bus architecture developed at NASA Ames Research Center. The challenge was building upon the existing modular common bus design and development work and improving the LADEE spacecraft design by adding an Equipotential Voltage Reference (EVeR) system, commonly referred to as a ground system. This would aid LADEE in meeting Electromagnetic Environmental Effects (E3) requirements, thereby making the spacecraft more compatible with itself and its space environment. The methods used to adapt existing hardware are presented, including provisions which may be used on future spacecraft.

  12. Development of a low-power, low-cost front end electronics module for large scale distributed neutrino detectors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    James J. Beatty

    2008-03-08

    especially critical. The frequency range of interest, {approx}200 MHz to {approx}1.2 GHz, is a transitional region where the lumped circuit element approach taken at low frequencies begins to reach limitations due to component tolerances, component losses, and parasitic effects. Active circuits can help to mitigate against these effects at the cost of added power consumption that becomes prohibitive for distributed experiments across the band of interest. At higher frequency microstrip, stripline, and other microwave techniques come to the fore. We have developed designs and design tools for passive filters extending the high frequency techniques to the frequency range of interest. Microstrip and stripline techniques are not usually attractive here because of the large physical dimensions of the resulting circuits, but in this application the tradeoff of size against power consumption favors this choice. These techniques are also intrinsically low-cost, as the filter is built into the circuit boards and the cost of components and their assembly onto the board is avoided. The basic element of the filter tree is an impedance matched wideband diplexer. This consists of a pair of low pass and high pass filters with a shared cutoff frequency and complementary frequency responses. These are designing the lowpass filter as a high order LC filter, which can be implemented as a series of transmission line segments of varying width. This can be transformed in to a CL high pass filter with a complementary frequency response. When the two filters are coupled to a common input, the input impedances of the networks add in parallel to give a constant input impedance as a function of frequency, with power flowing into one leg or the other of the filter pair. These filters can be cascaded to divide the band into the frequency ranges of interest; the broadband impedance matching at the inputs makes coupling of successive stages straightforward. These circuits can be produced in quantity at

  13. Development of portable defocusing micro-scale spatially offset Raman spectroscopy.

    PubMed

    Realini, Marco; Botteon, Alessandra; Conti, Claudia; Colombo, Chiara; Matousek, Pavel

    2016-05-10

    We present, for the first time, portable defocusing micro-Spatially Offset Raman Spectroscopy (micro-SORS). Micro-SORS is a concept permitting the analysis of thin, highly turbid stratified layers beyond the reach of conventional Raman microscopy. The technique is applicable to the analysis of painted layers in cultural heritage (panels, canvases and mural paintings, painted statues and decorated objects in general) as well as in many other areas including polymer, biological and biomedical applications, catalytic and forensics sciences where highly turbid stratified layers are present and where invasive analysis is undesirable or impossible. So far the technique has been demonstrated only on benchtop Raman microscopes precluding the non-invasive analysis of larger samples and samples in situ. The new set-up is characterised conceptually on a range of artificially assembled two-layer systems demonstrating its benefits and performance across several application areas. These included stratified polymer sample, pharmaceutical tablet and layered paint samples. The same samples were also analysed by a high performance (non-portable) benchtop Raman microscope to provide benchmarking against our earlier research. The realisation of the vision of delivering portability to micro-SORS has a transformative potential spanning across multiple disciplines as it fully unlocks, for the first time, the non-invasive and non-destructive aspects of micro-SORS enabling it to be applied also to large and non-portable samples in situ without recourse to removing samples, or their fragments, for laboratory analysis on benchtop Raman microscopes.

  14. Low-cost low-power uncooled a-Si-based micro infrared camera for unattended ground sensor applications

    NASA Astrophysics Data System (ADS)

    Schimert, Thomas R.; Ratcliff, David D.; Brady, John F., III; Ropson, Steven J.; Gooch, Roland W.; Ritchey, Bobbi; McCardel, P.; Rachels, K.; Wand, Marty; Weinstein, M.; Wynn, John

    1999-07-01

    Low power and low cost are primary requirements for an imaging infrared camera used in unattended ground sensor arrays. In this paper, an amorphous silicon (a-Si) microbolometer-based uncooled infrared camera technology offering a low cost, low power solution to infrared surveillance for UGS applications is presented. A 15 X 31 micro infrared camera (MIRC) has been demonstrated which exhibits an f/1 noise equivalent temperature difference sensitivity approximately 67 mK. This sensitivity has been achieved without the use of a thermoelectric cooler for array temperature stabilization thereby significantly reducing the power requirements. The chopperless camera is capable of operating from snapshot mode (1 Hz) to video frame rate (30 Hz). Power consumption of 0.4 W without display, and 0.75 W with display, respectively, has been demonstrated at 30 Hz operation. The 15 X 31 camera demonstrated exhibits a 35 mm camera form factor employing a low cost f/1 singlet optic and LED display, as well as low cost vacuum packaging. A larger 120 X 160 version of the MIRC is also in development and will be discussed. The 120 X 160 MIRC exhibits a substantially smaller form factor and incorporates all the low cost, low power features demonstrated in the 15 X 31 MIRC prototype. In this paper, a-Si microbolometer technology for the MIRC will be presented. Also, the key features and performance parameters of the MIRC are presented.

  15. Strategies to fight low-cost rivals.

    PubMed

    Kumar, Nirmalya

    2006-12-01

    Companies find it challenging and yet strangely reassuring to take on opponents whose strategies, strengths, and weaknesses resemble their own. Their obsession with familiar rivals, however, has blinded them to threats from disruptive, low-cost competitors. Successful price warriors, such as the German retailer Aldi, are changing the nature of competition by employing several tactics: focusing on just one or a few consumer segments, delivering the basic product or providing one benefit better than rivals do, and backing low prices with superefficient operations. Ignoring cutprice rivals is a mistake because they eventually force companies to vacate entire market segments. Price wars are not the answer, either: Slashing prices usually lowers profits for incumbents without driving the low-cost entrants out of business. Companies take various approaches to competing against cut-price players. Some differentiate their products--a strategy that works only in certain circumstances. Others launch low-cost businesses of their own, as many airlines did in the 1990s--a so-called dual strategy that succeeds only if companies can generate synergies between the existing businesses and the new ventures, as the financial service providers HSBC and ING did. Without synergies, corporations are better off trying to transform themselves into low-cost players, a difficult feat that Ryanair accomplished in the 1990s, or into solution providers. There will always be room for both low-cost and value-added players. How much room each will have depends not only on the industry and customers' preferences, but also on the strategies traditional businesses deploy.

  16. Field application of the Numobag as a portable disposable isolation unit and for treating chemical, radiological or biologically induced wounds.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Miller, Keith A.; Felton, Robert; Vaughan, Courtenay Thomas

    2005-04-01

    Numotech Inc. has developed the Numobag{trademark}, a disposable, lightweight, wound healing device which produces Topical Hyperbaric Oxygen Therapy (THOT). The Numobag{trademark} is cost effective and has been clinically validated to heal large skin lesions rapidly and has proven to arrest wound advancement from several insidious forms of biological attack including dermal anthrax, small pox, necrotizing fasciitis etc. The Numobag{trademark} can treat mass casualties wounded by chemical/radiological burns or damaging biological exposures. The Numobag{trademark} can be a frontline tool as an isolation unit, reducing cross-contamination and infection of medical personnel. The heightened oxygen content kills organisms on the skin and inmore » the wound, avoids expensive hospital trash disposal procedures, and helps the flesh heal. The Numobag{trademark} requires high purity oxygen. Numotech Inc. is teaming with Sandia National Laboratories and Spektr Conversion in Russia to develop a cost effective, portable, low power oxygen generator.« less

  17. Open source 3D printers: an appropriate technology for building low cost optics labs for the developing communities

    NASA Astrophysics Data System (ADS)

    Gwamuri, J.; Pearce, Joshua M.

    2017-08-01

    The recent introduction of RepRap (self-replicating rapid prototyper) 3-D printers and the resultant open source technological improvements have resulted in affordable 3-D printing, enabling low-cost distributed manufacturing for individuals. This development and others such as the rise of open source-appropriate technology (OSAT) and solar powered 3-D printing are moving 3-D printing from an industry based technology to one that could be used in the developing world for sustainable development. In this paper, we explore some specific technological improvements and how distributed manufacturing with open-source 3-D printing can be used to provide open-source 3-D printable optics components for developing world communities through the ability to print less expensive and customized products. This paper presents an open-source low cost optical equipment library which enables relatively easily adapted customizable designs with the potential of changing the way optics is taught in resource constraint communities. The study shows that this method of scientific hardware development has a potential to enables a much broader audience to participate in optical experimentation both as research and teaching platforms. Conclusions on the technical viability of 3-D printing to assist in development and recommendations on how developing communities can fully exploit this technology to improve the learning of optics through hands-on methods have been outlined.

  18. A low cost mobile phone dark-field microscope for nanoparticle-based quantitative studies.

    PubMed

    Sun, Dali; Hu, Tony Y

    2018-01-15

    Dark-field microscope (DFM) analysis of nanoparticle binding signal is highly useful for a variety of research and biomedical applications, but current applications for nanoparticle quantification rely on expensive DFM systems. The cost, size, limited robustness of these DFMs limits their utility for non-laboratory settings. Most nanoparticle analyses use high-magnification DFM images, which are labor intensive to acquire and subject to operator bias. Low-magnification DFM image capture is faster, but is subject to background from surface artifacts and debris, although image processing can partially compensate for background signal. We thus mated an LED light source, a dark-field condenser and a 20× objective lens with a mobile phone camera to create an inexpensive, portable and robust DFM system suitable for use in non-laboratory conditions. This proof-of-concept mobile DFM device weighs less than 400g and costs less than $2000, but analysis of images captured with this device reveal similar nanoparticle quantitation results to those acquired with a much larger and more expensive desktop DFMM system. Our results suggest that similar devices may be useful for quantification of stable, nanoparticle-based activity and quantitation assays in resource-limited areas where conventional assay approaches are not practical. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. Development of the International Space Station Fine Water Mist Portable Fire Extinguisher

    NASA Technical Reports Server (NTRS)

    Rodriquez, Branelle; Young, GIna

    2013-01-01

    The National Aeronautics and Space Administration (NASA) is developing a Fine Water Mist (FWM) Portable Fire Extinguisher (PFE) for use on the International Space Station (ISS). The ISS presently uses two different types of fire extinguishers: a water foam extinguisher in the Russian Segments, and a carbon dioxide extinguisher in the United States Orbital Segments, which include Columbus and Kibo pressurized elements. Currently, there are operational and compatibility concerns with the emergency breathing equipment and the carbon dioxide extinguisher. ISS emergency response breathing equipment does not filter carbon dioxide; therefore, crew members are required to have an oxygen supply present during a fire event since the carbon dioxide PFE creates an unsafe breathing environment. The ISS program recommended a nontoxic fire extinguisher to mitigate this operational risk. The FWM PFE can extinguish a fire without creating a hazardous breathing environment for crewmembers. This paper will discuss the unique functional and performance requirements that have been levied on the FWM PFE, identify unique microgravity design considerations for liquid and gas systems, and discuss the NASA ISS specific fire standards that were developed to establish an acceptable portable fire extinguisher s performance.

  20. Low-Cost Wireless Temperature Measurement: Design, Manufacture, and Testing of a PCB-Based Wireless Passive Temperature Sensor

    PubMed Central

    Yan, Dan; Yang, Yong; Hong, Yingping; Liang, Ting; Yao, Zong; Chen, Xiaoyong; Xiong, Jijun

    2018-01-01

    Low-cost wireless temperature measurement has significant value in the food industry, logistics, agriculture, portable medical equipment, intelligent wireless health monitoring, and many areas in everyday life. A wireless passive temperature sensor based on PCB (Printed Circuit Board) materials is reported in this paper. The advantages of the sensor include simple mechanical structure, convenient processing, low-cost, and easiness in integration. The temperature-sensitive structure of the sensor is a dielectric-loaded resonant cavity, consisting of the PCB substrate. The sensitive structure also integrates a patch antenna for the transmission of temperature signals. The temperature sensing mechanism of the sensor is the dielectric constant of the PCB substrate changes with temperature, which causes the resonant frequency variation of the resonator. Then the temperature can be measured by detecting the changes in the sensor’s working frequency. The PCB-based wireless passive temperature sensor prototype is prepared through theoretical design, parameter analysis, software simulation, and experimental testing. The high- and low-temperature sensing performance of the sensor is tested, respectively. The resonant frequency decreases from 2.434 GHz to 2.379 GHz as the temperature increases from −40 °C to 125 °C. The fitting curve proves that the experimental data have good linearity. Three repetitive tests proved that the sensor possess well repeatability. The average sensitivity is 347.45 KHz/°C℃ from repetitive measurements conducted three times. This study demonstrates the feasibility of the PCB-based wireless passive sensor, which provides a low-cost temperature sensing solution for everyday life, modern agriculture, thriving intelligent health devices, and so on, and also enriches PCB product lines and applications. PMID:29439393

  1. Low-Cost Wireless Temperature Measurement: Design, Manufacture, and Testing of a PCB-Based Wireless Passive Temperature Sensor.

    PubMed

    Yan, Dan; Yang, Yong; Hong, Yingping; Liang, Ting; Yao, Zong; Chen, Xiaoyong; Xiong, Jijun

    2018-02-10

    Low-cost wireless temperature measurement has significant value in the food industry, logistics, agriculture, portable medical equipment, intelligent wireless health monitoring, and many areas in everyday life. A wireless passive temperature sensor based on PCB (Printed Circuit Board) materials is reported in this paper. The advantages of the sensor include simple mechanical structure, convenient processing, low-cost, and easiness in integration. The temperature-sensitive structure of the sensor is a dielectric-loaded resonant cavity, consisting of the PCB substrate. The sensitive structure also integrates a patch antenna for the transmission of temperature signals. The temperature sensing mechanism of the sensor is the dielectric constant of the PCB substrate changes with temperature, which causes the resonant frequency variation of the resonator. Then the temperature can be measured by detecting the changes in the sensor's working frequency. The PCB-based wireless passive temperature sensor prototype is prepared through theoretical design, parameter analysis, software simulation, and experimental testing. The high- and low-temperature sensing performance of the sensor is tested, respectively. The resonant frequency decreases from 2.434 GHz to 2.379 GHz as the temperature increases from -40 °C to 125 °C. The fitting curve proves that the experimental data have good linearity. Three repetitive tests proved that the sensor possess well repeatability. The average sensitivity is 347.45 KHz / ℃ from repetitive measurements conducted three times. This study demonstrates the feasibility of the PCB-based wireless passive sensor, which provides a low-cost temperature sensing solution for everyday life, modern agriculture, thriving intelligent health devices, and so on, and also enriches PCB product lines and applications.

  2. GPS for low-cost attitude determination. A review of concepts, in-flight experiences, and current developments

    NASA Astrophysics Data System (ADS)

    Chu, Q. P.; Van Woerkom, P. Th. L. M.

    The Global Positioning System or GPS has been developed for the purpose of enabling accurate positioning and navigation anywhere on or near the surface of the Earth. In addition to the US system GPS-NAVSTAR, the Russian GLONASS system is also in place and operational. Other such systems are under study. The key measurement involved is the time of travel of signals from a particular GPS spacecraft to the navigating receiver. Navigation accuracies of the order of tenths of meters are achievable, and accuracies at the centimeter level can also be obtained with special enhancement techniques. In recent years spacecraft have already been exploring the use of GPS for in-orbit navigation. As the receiver is solid state, rugged, power-lean, and cheap, GPS for autonomous navigation will be an objective even for low-cost spacecraft of only modest sophistication. When the GPS receiver is equipped with multiple antennas with baselines even as low as about one meter, it can also give attitude information. In this case, the position of the spacecraft needs to be known with only very moderate accuracy. However, the phase differences between signals received by the different antennas now constitute the key measurements. In this case a centimeter level accuracy of range difference can be obtained. Receivers carrying out the processing of such measurements are already on the market, even in space-qualified versions. For spacecraft maneuvering at low rates, accuracies of the order of tenths of a degree are achievable. There are reasons for maintaining classical attitude sensor suites on a spacecraft even when a GPS receiver is added. In this case the classical sensors may be allowed to be of modest quality only, as subsequent fusion of their data with those from the GPS receiver may restore the accuracy of the final estimate again to an acceptable level. Hence, low-cost attitude sensors combined with a low-cost GPS receiver can still satisfy non-trivial attitude reconstitution

  3. Design guide for space shuttle low-cost payloads

    NASA Technical Reports Server (NTRS)

    1971-01-01

    A handbook is presented which delineates the principles of the new low-cost design methodology for designers of unmanned payloads to be carried by the space shuttle. The basic relationships between payload designs and program cost effects are discussed, and some concepts for designing low-cost payloads and implementing low-cost programs are given. The data are summarized from a payloads effects study of three unmanned earth satellites (OAO, a syneq orbiter, and a small research satellite), and the earth satellite design is emphasized. Brief summaries of space shuttle and space tug performance, environmental, and interface data pertinent to low-cost payload concepts are included.

  4. Development of a low-cost, low micro-vibration CMG for small agile satellite applications

    NASA Astrophysics Data System (ADS)

    Kawak, B. J.

    2017-02-01

    The agility of the spacecraft which refers to the spacecraft's ability to execute fast and accurate manoeuvers within a fixed period of time, is a key satellite parameter. The spacecraft' s agility is directly proportional to the spacecraft actuators' output torque. For high torque inertial actuators (>0.5 Nm), Control Moment Gyroscope (CMG) exhibits better performances in terms of mass and electrical power consumption than reaction wheels. However, in addition to the complex steering law required to avoid CMG singularities, one of the reasons why CMGs are not widely used is also due to their high micro-vibration emission which may interfere and disrupt the spacecraft' s sensitive instruments such as optical payloads. In this paper, an innovative two-stage viscoelastic isolation system has been designed and implemented in a new low micro-vibration CMG prototype. The first stage of the damping system acts at bearing level to attenuate the possible shock vibrations while the second stage acts at mechanism level to attenuate the structural resonances and motor noise. The developed CMG enables to combine high actuator output torque with a low micro-vibration signature. The viscoelastic damping system is cost effective as it is a fully passive system which requires no thermal control and no electronics. Furthermore, the attenuation provided by this innovative two stage damping system can reach a slope up to -80 dB/dec which leads to a Mini-CMG micro-vibration signature lower than similar output torque reaction wheels not equipped with a damping system.

  5. Stanford - USGS Ultra-Low Frequency Electromagnetic Network: Hardware Developments in Magnetometer Calibration and Data Recording

    NASA Astrophysics Data System (ADS)

    Bowden, D. C.; Engelland-Gay, H.; Enright, A.; Gardner, J.; Klemperer, S. L.; McPhee, D. K.; Glen, J. M.

    2010-12-01

    Since 2006 a collaborative effort between Stanford University, the USGS, and UC Berkeley has maintained five ultra-low frequency electromagnetic (UFLEM) stations along the San Andreas Fault system. The standard site is equipped with three orthogonal coil magnetometers and two sets of orthogonal 100m electrode pairs, provides data in the 0.01- 20 Hz bandwidth, and operates alongside a broadband seismometer. We intend to use these data to characterize the generation of subsurface EM signals, and determine whether there exists a correlation to seismic activity or tectonic processes of the region. Our EM data is archived with the collocated seismic data at UC Berkeley’s Northern California Earthquake Data Center (NCEDC) and is available to the public at http://ulfem-data.stanford.edu/. Two new hardware developments in 2010 will provide more reliable calibration of our magnetic recorders, and will improve station reliability while reducing station cost. We have developed a method for calibration of buried magnetic sensor coils. As our strategy for detecting possible EM anomalies related to earthquake processes relies on comparing measured EM signals across multiple sites, it is necessary to confirm that each magnetic sensor at each site responds similarly and accurately. A portable coil placed on the ground surface, in turn above each buried magnetic sensor, generates a time-varying magnetic field of known magnitude at several different known frequencies in the bandwidth of interest. In this way, the health of each sensor can be tested and factory produced response curve verified. Signal generation and power supply for the coil is designed to be cheap (< $100), easily portable, and exactly reproducible between trials to within 95%, but does require an operator visit to each site for the measurements. In the future we intend to modify the portable system to create a winding that can be permanently installed around every magnetic sensor to provide regular calibration by

  6. 24 CFR 982.636 - Homeownership option: Portability.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 24 Housing and Urban Development 4 2010-04-01 2010-04-01 false Homeownership option: Portability... Types Homeownership Option § 982.636 Homeownership option: Portability. (a) General. A family may... described in §§ 982.353 and 982.355 apply to the homeownership option and the administrative...

  7. Development of processes for the production of low cost silicon dendritic web for solar cells

    NASA Technical Reports Server (NTRS)

    Duncan, C. S.; Seidensticker, R. G.; Mchugh, J. P.; Hopkins, R. H.; Skutch, M. E.; Driggers, J. M.; Hill, F. E.

    1980-01-01

    High area output rates and continuous, automated growth are two key technical requirements for the growth of low-cost silicon ribbons for solar cells. By means of computer-aided furnace design, silicon dendritic web output rates as high as 27 sq cm/min have been achieved, a value in excess of that projected to meet a $0.50 per peak watt solar array manufacturing cost. The feasibility of simultaneous web growth while the melt is replenished with pelletized silicon has also been demonstrated. This step is an important precursor to the development of an automated growth system. Solar cells made on the replenished material were just as efficient as devices fabricated on typical webs grown without replenishment. Moreover, web cells made on a less-refined, pelletized polycrystalline silicon synthesized by the Battelle process yielded efficiencies up to 13% (AM1).

  8. A Novel Approach for a Low-Cost Deployable Antenna

    NASA Technical Reports Server (NTRS)

    Amend, Chris; Nurnberger, Michael; Oppenheimer, Paul; Koss, Steve; Purdy, Bill

    2010-01-01

    The Naval Research Laboratory (NRL) has designed, built, and fully qualified a low cost, low Passive Intermodulation (PIM) 12-foot (3.66-m) diameter deployable ultra high frequency (UHF) antenna for the Tacsat-4 program. The design utilized novel approaches in reflector material and capacitive coupling techniques. This paper discusses major design trades, unique design characteristics, and lessons learned from the development of the Tacsat 4 deployable antenna. This antenna development was sponsored by the Office of Naval Research.

  9. Review of Portable and Low-Cost Sensors for the Ambient Air Monitoring of Benzene and Other Volatile Organic Compounds

    PubMed Central

    Kok, Gertjan; Persijn, Stefan; Sauerwald, Tilman

    2017-01-01

    This article presents a literature review of sensors for the monitoring of benzene in ambient air and other volatile organic compounds. Combined with information provided by stakeholders, manufacturers and literature, the review considers commercially available sensors, including PID-based sensors, semiconductor (resistive gas sensors) and portable on-line measuring devices as for example sensor arrays. The bibliographic collection includes the following topics: sensor description, field of application at fixed sites, indoor and ambient air monitoring, range of concentration levels and limit of detection in air, model descriptions of the phenomena involved in the sensor detection process, gaseous interference selectivity of sensors in complex VOC matrix, validation data in lab experiments and under field conditions. PMID:28657595

  10. Review of Portable and Low-Cost Sensors for the Ambient Air Monitoring of Benzene and Other Volatile Organic Compounds.

    PubMed

    Spinelle, Laurent; Gerboles, Michel; Kok, Gertjan; Persijn, Stefan; Sauerwald, Tilman

    2017-06-28

    This article presents a literature review of sensors for the monitoring of benzene in ambient air and other volatile organic compounds. Combined with information provided by stakeholders, manufacturers and literature, the review considers commercially available sensors, including PID-based sensors, semiconductor (resistive gas sensors) and portable on-line measuring devices as for example sensor arrays. The bibliographic collection includes the following topics: sensor description, field of application at fixed sites, indoor and ambient air monitoring, range of concentration levels and limit of detection in air, model descriptions of the phenomena involved in the sensor detection process, gaseous interference selectivity of sensors in complex VOC matrix, validation data in lab experiments and under field conditions.

  11. A Low-Power and Portable Biomedical Device for Respiratory Monitoring with a Stable Power Source

    PubMed Central

    Yang, Jiachen; Chen, Bobo; Zhou, Jianxiong; Lv, Zhihan

    2015-01-01

    Continuous respiratory monitoring is an important tool for clinical monitoring. Associated with the development of biomedical technology, it has become more and more important, especially in the measuring of gas flow and CO2 concentration, which can reflect the status of the patient. In this paper, a new type of biomedical device is presented, which uses low-power sensors with a piezoresistive silicon differential pressure sensor to measure gas flow and with a pyroelectric sensor to measure CO2 concentration simultaneously. For the portability of the biomedical device, the sensors and low-power measurement circuits are integrated together, and the airway tube also needs to be miniaturized. Circuits are designed to ensure the stability of the power source and to filter out the existing noise. Modulation technology is used to eliminate the fluctuations at the trough of the waveform of the CO2 concentration signal. Statistical analysis with the coefficient of variation was performed to find out the optimal driving voltage of the pressure transducer. Through targeted experiments, the biomedical device showed a high accuracy, with a measuring precision of 0.23 mmHg, and it worked continuously and stably, thus realizing the real-time monitoring of the status of patients. PMID:26270665

  12. Low Cost Heliostat Development Phase II Final Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kusek, Stephen M.

    2013-04-30

    The heliostat field in a central receiver plant makes up roughly one half of the total plant cost. As such, cost reductions for the installed heliostat price greatly impact the overall plant cost and hence the plant’s Levelized Cost of Energy. The general trend in heliostat size over the past decades has been to make them larger. One part of our thesis has been that larger and larger heliostats may drive the LCOE up instead of down due to the very nature of the precise aiming and wind-load requirements for typical heliostats. In other words, it requires more and moremore » structure to precisely aim the sunlight at the receiver as one increases heliostat mirror area and that it becomes counter-productive, cost-wise, at some point.« less

  13. Scalable Light Module for Low-Cost, High-Efficiency Light- Emitting Diode Luminaires

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tarsa, Eric

    2015-08-31

    During this two-year program Cree developed a scalable, modular optical architecture for low-cost, high-efficacy light emitting diode (LED) luminaires. Stated simply, the goal of this architecture was to efficiently and cost-effectively convey light from LEDs (point sources) to broad luminaire surfaces (area sources). By simultaneously developing warm-white LED components and low-cost, scalable optical elements, a high system optical efficiency resulted. To meet program goals, Cree evaluated novel approaches to improve LED component efficacy at high color quality while not sacrificing LED optical efficiency relative to conventional packages. Meanwhile, efficiently coupling light from LEDs into modular optical elements, followed by optimallymore » distributing and extracting this light, were challenges that were addressed via novel optical design coupled with frequent experimental evaluations. Minimizing luminaire bill of materials and assembly costs were two guiding principles for all design work, in the effort to achieve luminaires with significantly lower normalized cost ($/klm) than existing LED fixtures. Chief project accomplishments included the achievement of >150 lm/W warm-white LEDs having primary optics compatible with low-cost modular optical elements. In addition, a prototype Light Module optical efficiency of over 90% was measured, demonstrating the potential of this scalable architecture for ultra-high-efficacy LED luminaires. Since the project ended, Cree has continued to evaluate optical element fabrication and assembly methods in an effort to rapidly transfer this scalable, cost-effective technology to Cree production development groups. The Light Module concept is likely to make a strong contribution to the development of new cost-effective, high-efficacy luminaries, thereby accelerating widespread adoption of energy-saving SSL in the U.S.« less

  14. Low Cost Benefit Suggestions.

    ERIC Educational Resources Information Center

    Doyel, Hoyt W.; McMillan, John D.

    1980-01-01

    Outlines eight low-cost employee benefits and summarizes their relative advantages. The eight include a stock ownership program, a sick leave pool, flexible working hours, production incentives, and group purchase plans. (IRT)

  15. Portable Life Support System 2.5 Fan Design and Development

    NASA Technical Reports Server (NTRS)

    Quinn, Gregory; Carra, Michael; Converse, David; Chullen, Cinda

    2016-01-01

    NASA is building a high-fidelity prototype of an advanced Portable Life Support System (PLSS) as part of the Advanced Exploration Systems Program. This new PLSS, designated as PLSS 2.5, will advance component technologies and systems knowledge to inform a future flight program. The oxygen ventilation loop of its predecessor, PLSS 2.0, was driven by a centrifugal fan developed using specifications from the Constellation Program. PLSS technology and system parameters have matured to the point where the existing fan will not perform adequately for the new prototype. In addition, areas of potential improvement were identified with the PLSS 2.0 fan that could be addressed in a new design. As a result, a new fan was designed and tested for the PLSS 2.5. The PLSS 2.5 fan is a derivative of the one used in PLSS 2.0, and it uses the same nonmetallic, canned motor, with a larger volute and impeller to meet the higher pressure drop requirements of the PLSS 2.5 ventilation loop. The larger impeller allows it to operate at rotational speeds that are matched to rolling element bearings, and which create reasonably low impeller tip speeds consistent with prior, oxygen-rated fans. Development of the fan also considered a shrouded impeller design that could allow larger clearances for greater oxygen safety, assembly tolerances and particle ingestion. This paper discusses the design, manufacturing and performance testing of the new fans.

  16. Development of a low-cost sun sensor for nanosatellites

    NASA Astrophysics Data System (ADS)

    Antonello, Andrea; Olivieri, Lorenzo; Francesconi, Alessandro

    2018-03-01

    Sun sensors represent a common and reliable technology for attitude determination, employed in many space missions thanks to their limited size and weight. Typically, two-axis digital Sun sensors employ an array of active pixels arranged behind a small aperture; the position of the sunlight's spot allows to determine the direction of the Sun. With the advent of smaller vehicles such as CubeSats and Nanosats, there is the need to further reduce the size and weight of such devices: as a trade-off, this usually results in the curtail of the performances. Nowadays, state of the art Sun sensors for CubeSats have resolutions of about 0.5°, with fields of view in the ±45° to ±90° range, with off-the-self prices of several thousands of dollars. In this work we introduce a novel low-cost miniaturized Sun sensor, based on a commercial CMOS camera detector; its main feature is the reduced size with respect to state-of-the-art sensors developed from the same technology, making it employable on CubeSats. The sensor consists of a precisely machined pinhole with a 10 μm circular aperture, placed at a distance of 7 mm from the CMOS. The standoff distance and casing design allow for a maximum resolution of less than 0.03°, outperforming most of the products currently available for nano and pico platforms; furthermore, the nature of the technology allows for reduced size and lightweight characteristics. The design, development and laboratory tests of the sensor are here introduced, starting with the definition of the physical model, the geometrical layout and its theoretical resolution; a more accurate model was then developed in order to account for the geometrical deviations and deformations of the pinhole-projected light-spot, as well as to account for the background noise and disturbances to the electronics. Finally, the laboratory setup is presented along with the test campaigns: the results obtained are compared with the simulations, allowing for the validation of the

  17. Size-selective sampling performance of six low-volume “total” suspended particulate (TSP) inlets

    EPA Science Inventory

    Several low-volume inlets (flow rates ≤ 16.7 liters per minute (Lpm)) are commercially available as components of low-cost, portable ambient particulate matter samplers. Because the inlets themselves do not contain internal fractionators, they are often assumed to representati...

  18. The FORCE - A highly portable parallel programming language

    NASA Technical Reports Server (NTRS)

    Jordan, Harry F.; Benten, Muhammad S.; Alaghband, Gita; Jakob, Ruediger

    1989-01-01

    This paper explains why the FORCE parallel programming language is easily portable among six different shared-memory multiprocessors, and how a two-level macro preprocessor makes it possible to hide low-level machine dependencies and to build machine-independent high-level constructs on top of them. These FORCE constructs make it possible to write portable parallel programs largely independent of the number of processes and the specific shared-memory multiprocessor executing them.

  19. The FORCE: A highly portable parallel programming language

    NASA Technical Reports Server (NTRS)

    Jordan, Harry F.; Benten, Muhammad S.; Alaghband, Gita; Jakob, Ruediger

    1989-01-01

    Here, it is explained why the FORCE parallel programming language is easily portable among six different shared-memory microprocessors, and how a two-level macro preprocessor makes it possible to hide low level machine dependencies and to build machine-independent high level constructs on top of them. These FORCE constructs make it possible to write portable parallel programs largely independent of the number of processes and the specific shared memory multiprocessor executing them.

  20. Rugged, Low Cost, Environmental Sensors for a Turbulent World

    NASA Astrophysics Data System (ADS)

    Schulz, B.; Sandell, C. T.; Wickert, A. D.

    2017-12-01

    Ongoing scientific research and resource management require a diverse range of high-quality and low-cost sensors to maximize the number and type of measurements that can be obtained. To accomplish this, we have developed a series of diversified sensors for common environmental applications. The TP-DownHole is an ultra-compact temperature and pressure sensor designed for use in CMT (Continuous Multi-channel Tubing) multi-level wells. Its 1 mm water depth resolution, 30 cm altitude resolution, and rugged design make it ideal for both water level measurements and monitoring barometric pressure and associated temperature changes. The TP-DownHole sensor has also been incorporated into a self-contained, fully independent data recorder for extreme and remote environments. This device (the TP-Solo) is based around the TP-DownHole design, but has self-contained power and data storage and is designed to collect data independently for up to 6 months (logging at once an hour), creating a specialized tool for extreme environment data collection. To gather spectral information, we have also developed a very low cost photodiode-based Lux sensor to measure spectral irradiance; while this does not measure the entire solar radiation spectrum, simple modeling to rescale the remainder of the solar spectrum makes this a cost-effective alternative to a thermopile pyranometer. Lastly, we have developed an instrumentation amplifier which is designed to interface a wide range of sensitive instruments to common data logging systems, such as thermopile pyranometers, thermocouples, and many other analog output sensors. These three instruments are the first in a diverse family aimed to give researchers a set of powerful and low-cost tools for environmental instrumentation.