Science.gov

Sample records for em dois transectos

  1. The DOI Is Coming.

    ERIC Educational Resources Information Center

    Scharf, Davida

    2002-01-01

    Discussion of improving accessibility to copyrighted electronic content focuses on the Digital Object Identifier (DOI) and the Open URL standard and linking software. Highlights include work of the World Wide Web consortium; URI (Uniform Resource Identifier); URL (Uniform Resource Locator); URN (Uniform Resource Name); OCLC's (Online Computer…

  2. DOI: A New Identifier for Digital Content.

    ERIC Educational Resources Information Center

    Berinstein, Paula

    1998-01-01

    Previews Digital Object Identifiers (DOIs), a potential unifying classification system for the Web and the Internet developed by the Association of American Publishers and the Corporation for National Research Initiatives. Discusses issues and problems surrounding DOI implementation and usage and how DOI would affect publishers, users,…

  3. ESDIS DOI System, Approach, and Future Direction

    NASA Astrophysics Data System (ADS)

    Wanchoo, L.; James, N.

    2013-12-01

    NASA's Earth Science Data and Information System (ESDIS) Project began investigating the use of Digital Object Identifiers (DOIs) in 2010 with the goal of assigning DOIs to various data products. These data products are archived and distributed by various Distributed Active Archive Centers (DAACs) located across the United States. Each data center has a unique approach and process for generating and archiving a variety of data products that are used for global change research. These varied approaches present a challenge for developing a DOI solution that fits all the possible variations. To address this challenge, ESDIS developed processes, guidelines, and several models for creating and assigning DOIs. Initially the system was started as a prototype approach and now it is fully operational. In February 2012, ESDIS joined the California Digital Library (CDL) EZID for registering the EOSDIS-related DOIs. ESDIS's DOI operational process allows for reserving DOIs while data providers are finalizing the DOIs and its associated elements. This flexibility allows data providers to embed and test the DOI in the data product metadata before formally registering with EZID. Data providers can change any DOI metadata, including the DOI name as long as it has not been registered or reserved by another data provider. ESDIS assures the uniqueness of the DOI names before it is registered. Currently, ESDIS has 146 data product DOIs registered with EZID and data providers have reserved an additional 93 DOIs with ESDIS. A semi-automated approach is being developed for processing and validating the DOI information provided by the data providers and will cover all the steps from the collection to the registration of DOIs. ESDIS's DOI concept utilizes a few mandatory metadata elements that effectively identify the data products and the source of availability. Of these elements, the Uniform Resource Locator (URL) attribute has the very important function of identifying the landing page

  4. DOI or Don't We?

    ERIC Educational Resources Information Center

    Caplan, Priscilla

    1998-01-01

    Explains digital object identifier (DOI) which was developed to facilitate digital commerce by maintaining persistent links to the rights holder of a digital object. Topics include uniform resource locators (URLs); uniform resource names (URNs); and Handle System software. (Author/LRW)

  5. DOIs Should Not Link to Data

    NASA Astrophysics Data System (ADS)

    Hourcle, J. A.

    2013-12-01

    In August of 2011, the National Academy of Science's Board of Research Data and Information (BRDI) had a meeting on the topic of "Developing Data Attribution and Citation Practices and Standards". As part of that meeting were various breakout groups to discuss issues that still remained regarding technical, scientific, and socio-cultural issues, the roles and actors that needed to be involved, and how to get additional feedback from the community. The technical breakout group decided that the majority of the technical problems with citing data revolved around establishing the identity of what it was that we were attempting to cite. As such, our recommendations were to push some of the work back onto the data publishers to tell us how scientists should cite their data (to avoid different disciplines applying different rules), establish 'data landing pages' to describe, document and link to the data, and to provide those pages with persistent identifiers such as a DOI. We present here some of the reasons that were discussed about why not to link directly to data, including: * recalibration, reaccessioning and other data impermanence, * setting context and providing for links to documentation, and * allowing selection of different packaging formats

  6. 30 CFR 250.1005 - Inspection requirements for DOI pipelines.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 2 2012-07-01 2012-07-01 false Inspection requirements for DOI pipelines. 250... THE INTERIOR OFFSHORE OIL AND GAS AND SULPHUR OPERATIONS IN THE OUTER CONTINENTAL SHELF Pipelines and Pipeline Rights-of-Way § 250.1005 Inspection requirements for DOI pipelines. (a) Pipeline routes shall...

  7. 30 CFR 250.1005 - Inspection requirements for DOI pipelines.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 2 2014-07-01 2014-07-01 false Inspection requirements for DOI pipelines. 250... THE INTERIOR OFFSHORE OIL AND GAS AND SULPHUR OPERATIONS IN THE OUTER CONTINENTAL SHELF Pipelines and Pipeline Rights-of-Way § 250.1005 Inspection requirements for DOI pipelines. (a) Pipeline routes shall...

  8. 30 CFR 250.1005 - Inspection requirements for DOI pipelines.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 2 2013-07-01 2013-07-01 false Inspection requirements for DOI pipelines. 250... THE INTERIOR OFFSHORE OIL AND GAS AND SULPHUR OPERATIONS IN THE OUTER CONTINENTAL SHELF Pipelines and Pipeline Rights-of-Way § 250.1005 Inspection requirements for DOI pipelines. (a) Pipeline routes shall...

  9. 30 CFR 250.1005 - Inspection requirements for DOI pipelines.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 2 2011-07-01 2011-07-01 false Inspection requirements for DOI pipelines. 250... Pipelines and Pipeline Rights-of-Way § 250.1005 Inspection requirements for DOI pipelines. (a) Pipeline... indication of pipeline leakage. The results of these inspections shall be retained for at least 2 years...

  10. 30 CFR 250.1005 - Inspection requirements for DOI pipelines.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 2 2010-07-01 2010-07-01 false Inspection requirements for DOI pipelines. 250.1005 Section 250.1005 Mineral Resources MINERALS MANAGEMENT SERVICE, DEPARTMENT OF THE INTERIOR...-Way § 250.1005 Inspection requirements for DOI pipelines. (a) Pipeline routes shall be inspected...

  11. Implementing DOIs for Oceanographic Satellite Data at PO.DAAC

    NASA Astrophysics Data System (ADS)

    Hausman, J.; Tauer, E.; Chung, N.; Chen, C.; Moroni, D. F.

    2013-12-01

    The Physical Oceanographic Distributed Active Archive Center (PO.DAAC) is NASA's archive for physical oceanographic satellite data. It distributes over 500 datasets from gravity, ocean wind, sea surface topography, sea ice, ocean currents, salinity, and sea surface temperature satellite missions. A dataset is a collection of granules/files that share the same mission/project, versioning, processing level, spatial, and temporal characteristics. The large number of datasets is partially due to the number of satellite missions, but mostly because a single satellite mission typically has multiple versions or even temporal and spatial resolutions of data. As a result, a user might mistake one dataset for a different dataset from the same satellite mission. Due to the PO.DAAC'S vast variety and volume of data and growing requirements to report dataset usage, it has begun implementing DOIs for the datasets it archives and distributes. However, this was not as simple as registering a name for a DOI and providing a URL. Before implementing DOIs multiple questions needed to be answered. What are the sponsor and end-user expectations regarding DOIs? At what level does a DOI get assigned (dataset, file/granule)? Do all data get a DOI, or only selected data? How do we create a DOI? How do we create landing pages and manage them? What changes need to be made to the data archive, life cycle policy and web portal to accommodate DOIs? What if the data also exists at another archive and a DOI already exists? How is a DOI included if the data were obtained via a subsetting tool? How does a researcher or author provide a unique, definitive reference (standard citation) for a given dataset? This presentation will discuss how these questions were answered through changes in policy, process, and system design. Implementing DOIs is not a trivial undertaking, but as DOIs are rapidly becoming the de facto approach, it is worth the effort. Researchers have historically referenced the source

  12. STS-87 Mission Specialist Doi in white room

    NASA Technical Reports Server (NTRS)

    1997-01-01

    STS-87 Mission Specialist Takao Doi, Ph.D., of the National Space Development Agency of Japan, is assisted with his ascent and re- entry flight suit by Dave Law, USA mechanical technician, in the white room at Launch Pad 39B as Dr. Doi prepares to enter the Space Shuttle orbiter Columbia on launch day. At right wearing glasses is Danny Wyatt, NASA quality assurance specialist. STS-87 is the fourth flight of the United States Microgravity Payload and Spartan-201. The 16-day mission will include a spacewalk by Dr. Doi and Mission Specialist Winston Scott.

  13. Mathematical Existence Results for the Doi-Edwards Polymer Model

    NASA Astrophysics Data System (ADS)

    Chupin, Laurent

    2016-07-01

    In this paper, we present some mathematical results on the Doi-Edwards model describing the dynamics of flexible polymers in melts and concentrated solutions. This model, developed in the late 1970s, has been used and extensively tested in modeling and simulation of polymer flows. From a mathematical point of view, the Doi-Edwards model consists in a strong coupling between the Navier-Stokes equations and a highly nonlinear constitutive law. The aim of this article is to provide a rigorous proof of the well-posedness of the Doi-Edwards model, namely that it has a unique regular solution. We also prove, which is generally much more difficult for flows of viscoelastic type, that the solution is global in time in the two dimensional case, without any restriction on the smallness of the data.

  14. Image reconstruction algorithms for DOIS: a diffractive optic image spectrometer

    NASA Astrophysics Data System (ADS)

    Lyons, Denise M.; Whitcomb, Kevin J.

    1996-06-01

    The diffractive optic imaging spectrometer, DOIS, is a compact, economical, rugged, programmable, multi-spectral imager. The design implements a conventional CCD camera and emerging diffractive optical element (DOE) technology in an elegant configuration, adding spectroscopy capabilities to current imaging systems (Lyons 1995). This paper reports on the visible prototype DOIS that was designed, fabricated and characterized. Algorithms are presented for simulation and post-detection processing with digital image processing techniques. This improves the spectral resolution by removing unwanted blurred components from the spectral images. DOIS is a practical image spectrometer that can be built to operate at ultraviolet, visible or infrared wavelengths for applications in surveillance, remote sensing, law enforcement, environmental monitoring, laser communications, and laser counter intelligence.

  15. STS-87 Mission Specialist Takao Doi during CEIT

    NASA Technical Reports Server (NTRS)

    1997-01-01

    STS-87 Mission Specialist Takao Doi , Ph.D., of the National Space Development Agency of Japan, participates in the Crew Equipment Integration Test (CEIT) in Kennedy Space Centers (KSC's) Vertical Processing Facility. Glenda Laws, the extravehicular activity (EVA) coordinator, Johnson Space Center, stands behind Dr. Doi. The CEIT gives astronauts an opportunity to get a hands-on look at the payloads with which they will be working on-orbit. STS-87 will be the fourth United States Microgravity Payload and flight of the Spartan-201 deployable satellite. During the mission, Dr. Doi will be the first Japanese astronaut to perform a spacewalk. STS-87 is scheduled for a Nov. 19 liftoff from KSC.

  16. STS-87 Mission Specialist Takao Doi suits up

    NASA Technical Reports Server (NTRS)

    1997-01-01

    STS-87 Mission Specialist Takao Doi, Ph.D., of the National Space Development Agency of Japan, gives a thumbs up in his launch and entry suit in the Operations and Checkout Building. He and the five other crew members will depart shortly for Launch Pad 39B, where the Space Shuttle Columbia awaits liftoff on a 16-day mission to perform microgravity and solar research. Dr. Doi is scheduled to perform an extravehicular activity spacewalk with Mission Specialist Winston Scott during STS-87.

  17. "Doi Moi" (Renovation) and Higher Education Reform in Vietnam

    ERIC Educational Resources Information Center

    Thanh, Pham Thi Hong

    2011-01-01

    Vietnam has experienced significant social, economic, political, and educational changes during the last two decades since the "Doi Moi" policy was implemented. To respond to new requirements required by the global economy, Vietnamese education has undergone remarkable reforms. This article critically examines these reforms in three areas:…

  18. Introduction of digital object identifiers (DOI) for seismic networks

    NASA Astrophysics Data System (ADS)

    Evans, Peter; Strollo, Angelo; Clark, Adam; Ahern, Tim; Newman, Rob; Clinton, John; Pequegnat, Catherine; Pedersen, Helle

    2015-04-01

    Proper attribution for scientific source data is important in promoting transparency and recognising the role of data providers in science. Data sets such as those produced by seismic networks now need to be citable and permanently locatable for research users. Recently the EIDA and IRIS-DMC communities have worked together on development of methods for generation, maintenance and promotion of persistent identifiers for seismic networks. This resulted in a 2014 Recommendation by the International Federation of Digital Seismograph Networks (FDSN) on the use of Digital Object Identifiers (DOI) for seismic networks. These can be cited equivalently to scientific papers, and tools such as DataCite allow the tracking of citations to these datasets. The GEOFON, IRIS and RESIF data centres have now begun to roll-out of these seismic network DOIs. This has involved working with principal investigators to prepare metadata consistent with the FDSN recommendation, preparation of landing pages, and changes to the web sites to promote DOIs where available. This has involved preparing improved descriptions of the data (metadata) and clarifying how individuals and institutions should best be recognised for their contributions to making the data available. We illustrate this process for a few representative networks. We will be in contact with additional network operators to help them establish DOIs for their networks in future.

  19. Did Oligocene crustal thickening precede basin development in northern Thailand? A geochronological reassessment of Doi Inthanon and Doi Suthep

    NASA Astrophysics Data System (ADS)

    Gardiner, Nicholas J.; Roberts, Nick M. W.; Morley, Christopher K.; Searle, Michael P.; Whitehouse, Martin J.

    2016-01-01

    The Doi Inthanon and Doi Suthep metamorphic core complexes in northern Thailand are comprised of amphibolite-grade migmatitic gneisses mantled by lower-grade mylonites and metasedimentary sequences, thought to represent Cordilleran-style core complexes exhumed through the mobilization of a low-angle detachment fault. Previous studies have interpreted two metamorphic events (Late Triassic and Late Cretaceous), followed by ductile extension between the late Eocene and late Oligocene, a model which infers movement on the detachment at ca. 40 Ma, and which culminates in a rapid unroofing of the complexes in the early Miocene. The Chiang Mai Basin, the largest such Cenozoic Basin in the region, lies immediately to the east. Its development is related to the extension observed at Doi Inthanon and Doi Suthep, however it is not definitively dated, and models for its development have difficulty reconciling Miocene cooling ages with Eocene detachment movement. Here we present new in-situ LA-ICP-MS and SIMS U-Pb age data of zircon and monazite grains from gneiss and leucogranite samples taken from Doi Inthanon and Doi Suthep. Our new zircon data exhibit an older age range of 221-210 Ma, with younger ages of ca. 72 Ma, and 32-26 Ma. Our monazite data imply an older age cluster at 83-67 Ma, and a younger age cluster of 34-24 Ma. While our data support the view of Indosinian basement being reworked in the Cretaceous, they also indicate a late Eocene-Oligocene tectonothermal event, resulting in prograde metamorphism and anatexis. We suggest that this later event is related to localized transpressional thickening associated with sinistral movement on the Mae Ping Fault, coupled with thickening at the restraining bend of the Mae Yuan Fault to the immediate west of Doi Inthanon. Further, this upper Oligocene age limit from our zircon and monazite data would imply a younger Miocene constraint on movement of the detachment, which, when combined with the previously recorded Miocene

  20. A flood map based DOI decoding method for block detector: a GATE simulation study.

    PubMed

    Shi, Han; Du, Dong; Su, Zhihong; Peng, Qiyu

    2014-01-01

    Positron Emission Tomography (PET) systems using detectors with Depth of Interaction (DOI) capabilities could achieve higher spatial resolution and better image quality than those without DOI. Up till now, most DOI methods developed are not cost-efficient for a whole body PET system. In this paper, we present a DOI decoding method based on flood map for low-cost conventional block detector with four-PMT readout. Using this method, the DOI information can be directly extracted from the DOI-related crystal spot deformation in the flood map. GATE simulations are then carried out to validate the method, confirming a DOI sorting accuracy of 85.27%. Therefore, we conclude that this method has the potential to be applied in conventional detectors to achieve a reasonable DOI measurement without dramatically increasing their complexity and cost of an entire PET system. PMID:25227021

  1. 43 CFR 2.34 - Where can I get a copy of DOI's FOIA annual report?

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 43 Public Lands: Interior 1 2011-10-01 2011-10-01 false Where can I get a copy of DOI's FOIA... AND TESTIMONY; FREEDOM OF INFORMATION ACT FOIA Annual Report § 2.34 Where can I get a copy of DOI's FOIA annual report? Under 5 U.S.C. 552(e), DOI is required to prepare an annual report regarding...

  2. 41 CFR 102-75.650 - When must DOI request assignment of the property?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 41 Public Contracts and Property Management 3 2010-07-01 2010-07-01 false When must DOI request...-75.650 When must DOI request assignment of the property? Within 30 calendar days after the expiration of the 30-calendar day period specified in § 102-75.640, DOI must submit to the disposal agency...

  3. 43 CFR 2.31 - How will DOI respond to my appeal?

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 43 Public Lands: Interior 1 2010-10-01 2010-10-01 false How will DOI respond to my appeal? 2.31... OF INFORMATION ACT FOIA Appeals § 2.31 How will DOI respond to my appeal? (a) Appeals will be decided... will state the basis for DOI's decision as follows: (1) Decision to release or withhold records. (i)...

  4. 43 CFR 2.34 - Where can I get a copy of DOI's FOIA annual report?

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 43 Public Lands: Interior 1 2010-10-01 2010-10-01 false Where can I get a copy of DOI's FOIA... AND TESTIMONY; FREEDOM OF INFORMATION ACT FOIA Annual Report § 2.34 Where can I get a copy of DOI's FOIA annual report? Under 5 U.S.C. 552(e), DOI is required to prepare an annual report regarding...

  5. 43 CFR 45.25 - What will DOI do with any hearing requests?

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 43 Public Lands: Interior 1 2010-10-01 2010-10-01 false What will DOI do with any hearing requests... PRESCRIPTIONS IN FERC HYDROPOWER LICENSES Hearing Process Initiation of Hearing Process § 45.25 What will DOI do... will refer the case for a hearing as follows: (1) If the hearing is to be conducted by DOI, OEPC...

  6. 43 CFR 17.314 - Age distinctions contained in DOI regulations.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 43 Public Lands: Interior 1 2010-10-01 2010-10-01 false Age distinctions contained in DOI... Age Standards for Determining Age Discrimination § 17.314 Age distinctions contained in DOI regulations. Any age distinctions contained in a rule or regulation issued by DOI shall be presumed to...

  7. A High Resolution Monolithic Crystal, DOI, MR Compatible, PET Detector

    SciTech Connect

    Robert S Miyaoka

    2012-03-06

    The principle objective of this proposal is to develop a positron emission tomography (PET) detector with depth-of-interaction (DOI) positioning capability that will achieve state of the art spatial resolution and sensitivity performance for small animal PET imaging. When arranged in a ring or box detector geometry, the proposed detector module will support <1 mm3 image resolution and >15% absolute detection efficiency. The detector will also be compatible with operation in a MR scanner to support simultaneous multi-modality imaging. The detector design will utilize a thick, monolithic crystal scintillator readout by a two-dimensional array of silicon photomultiplier (SiPM) devices using a novel sensor on the entrance surface (SES) design. Our hypothesis is that our single-ended readout SES design will provide an effective DOI positioning performance equivalent to more expensive dual-ended readout techniques and at a significantly lower cost. Our monolithic crystal design will also lead to a significantly lower cost system. It is our goal to design a detector with state of the art performance but at a price point that is affordable so the technology can be disseminated to many laboratories. A second hypothesis is that using SiPM arrays, the detector will be able to operate in a MR scanner without any degradation in performance to support simultaneous PET/MR imaging. Having a co-registered MR image will assist in radiotracer localization and may also be used for partial volume corrections to improve radiotracer uptake quantitation. The far reaching goal of this research is to develop technology for medical research that will lead to improvements in human health care.

  8. 43 CFR 2.34 - Where can I get a copy of DOI's FOIA annual report?

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 43 Public Lands: Interior 1 2012-10-01 2011-10-01 true Where can I get a copy of DOI's FOIA annual... TESTIMONY; FREEDOM OF INFORMATION ACT FOIA Annual Report § 2.34 Where can I get a copy of DOI's FOIA annual report? Under 5 U.S.C. 552(e), DOI is required to prepare an annual report regarding its FOIA...

  9. [Computer simulation of DOI-PET detector (1) -analysis of DOI discrimination accuracy in a detector block-].

    PubMed

    Yamada, Akira; Haneishi, Hideaki; Inadama, Naoko; Murayama, Hideo

    2003-01-01

    A detector proposed by Murayama et al. for detection of depth-of-interaction (DOI) in PET consists of three-dimensionally arranged crystal elements with proper optical reflectors and is coupled to an array of photomultiplier tubes. This detector has a great advantage in easiness and cost in fabrication. We implemented a simulator of this detector that allows us to find appropriate values of parameters such as optical properties of crystal or detector unit geometry before making detectors. The simulator is based on the Monte Carlo method that traces the migration of optical photons generated by interaction of a gamma ray with crystal. First, the simulator performance was validated by comparing with the experimental data obtained with some prototype detectors. Then, on some parameters including refractive index of inter-crystal material, reflectance of optical reflector and detector geometry, appropriate values were investigated for accurate discrimination of crystal element of interaction. PMID:12832869

  10. 43 CFR 2.32 - How long does DOI have to respond to my appeal?

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 43 Public Lands: Interior 1 2012-10-01 2011-10-01 true How long does DOI have to respond to my... TESTIMONY; FREEDOM OF INFORMATION ACT FOIA Appeals § 2.32 How long does DOI have to respond to my appeal? (a... have not received a decision on your appeal within 20 workdays, you have the right to seek review in...

  11. 43 CFR 45.25 - What will DOI do with any hearing requests?

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 43 Public Lands: Interior 1 2011-10-01 2011-10-01 false What will DOI do with any hearing requests? 45.25 Section 45.25 Public Lands: Interior Office of the Secretary of the Interior CONDITIONS AND PRESCRIPTIONS IN FERC HYDROPOWER LICENSES Hearing Process Initiation of Hearing Process § 45.25 What will DOI...

  12. 43 CFR 45.25 - What will DOI do with any hearing requests?

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 43 Public Lands: Interior 1 2013-10-01 2013-10-01 false What will DOI do with any hearing requests? 45.25 Section 45.25 Public Lands: Interior Office of the Secretary of the Interior CONDITIONS AND PRESCRIPTIONS IN FERC HYDROPOWER LICENSES Hearing Process Initiation of Hearing Process § 45.25 What will DOI...

  13. 43 CFR 45.25 - What will DOI do with any hearing requests?

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 43 Public Lands: Interior 1 2012-10-01 2011-10-01 true What will DOI do with any hearing requests? 45.25 Section 45.25 Public Lands: Interior Office of the Secretary of the Interior CONDITIONS AND PRESCRIPTIONS IN FERC HYDROPOWER LICENSES Hearing Process Initiation of Hearing Process § 45.25 What will DOI...

  14. 43 CFR 45.25 - What will DOI do with any hearing requests?

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 43 Public Lands: Interior 1 2014-10-01 2014-10-01 false What will DOI do with any hearing requests? 45.25 Section 45.25 Public Lands: Interior Office of the Secretary of the Interior CONDITIONS AND PRESCRIPTIONS IN FERC HYDROPOWER LICENSES Hearing Process Initiation of Hearing Process § 45.25 What will DOI...

  15. 43 CFR 2.5 - Does DOI maintain an index of its reading room materials?

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 43 Public Lands: Interior 1 2011-10-01 2011-10-01 false Does DOI maintain an index of its reading... a FOIA Request § 2.5 Does DOI maintain an index of its reading room materials? Each bureau will maintain and make available for public inspection and copying a current subject-matter index of its...

  16. 30 CFR 250.1004 - Safety equipment requirements for DOI pipelines.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 2 2011-07-01 2011-07-01 false Safety equipment requirements for DOI pipelines... SHELF Pipelines and Pipeline Rights-of-Way § 250.1004 Safety equipment requirements for DOI pipelines... required by this section on all incoming, departing, and crossing pipelines on platforms....

  17. 43 CFR 17.301 - What is the purpose of DOI's age discrimination regulations?

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... general age discrimination regulations at 45 CFR part 90. The Act and the general regulations prohibit... 43 Public Lands: Interior 1 2010-10-01 2010-10-01 false What is the purpose of DOI's age... Age General § 17.301 What is the purpose of DOI's age discrimination regulations? The purpose of...

  18. 43 CFR 2.5 - Does DOI maintain an index of its reading room materials?

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 43 Public Lands: Interior 1 2010-10-01 2010-10-01 false Does DOI maintain an index of its reading room materials? 2.5 Section 2.5 Public Lands: Interior Office of the Secretary of the Interior RECORDS... a FOIA Request § 2.5 Does DOI maintain an index of its reading room materials? Each bureau...

  19. 30 CFR 250.1003 - Installation, testing, and repair requirements for DOI pipelines.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 2 2010-07-01 2010-07-01 false Installation, testing, and repair requirements for DOI pipelines. 250.1003 Section 250.1003 Mineral Resources MINERALS MANAGEMENT SERVICE, DEPARTMENT... and Pipeline Rights-of-Way § 250.1003 Installation, testing, and repair requirements for DOI...

  20. 25 CFR 1000.232 - When must DOI respond to a request for reconsideration?

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 25 Indians 2 2010-04-01 2010-04-01 false When must DOI respond to a request for reconsideration? 1000.232 Section 1000.232 Indians OFFICE OF THE ASSISTANT SECRETARY, INDIAN AFFAIRS, DEPARTMENT OF THE...-DETERMINATION AND EDUCATION ACT Waiver of Regulations § 1000.232 When must DOI respond to a request...

  1. 77 FR 17493 - Agency Information Collection Activities: Proposed Collection; Comment Request; DOI Generic...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-03-26

    ... December 22, 2010 (75 FR 80542). We again request public comments on this proposed information collection...; DOI Generic Clearance for the Collection of Qualitative Feedback on Agency Service Delivery AGENCY... Interior has submitted a Generic Information Collection Request (Generic ICR): ``DOI Generic Clearance...

  2. 43 CFR 2.2 - What is DOI's policy regarding release of records under the FOIA?

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 43 Public Lands: Interior 1 2010-10-01 2010-10-01 false What is DOI's policy regarding release of records under the FOIA? 2.2 Section 2.2 Public Lands: Interior Office of the Secretary of the Interior RECORDS AND TESTIMONY; FREEDOM OF INFORMATION ACT General Information § 2.2 What is DOI's policy...

  3. 30 CFR 250.1004 - Safety equipment requirements for DOI pipelines.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 2 2010-07-01 2010-07-01 false Safety equipment requirements for DOI pipelines. 250.1004 Section 250.1004 Mineral Resources MINERALS MANAGEMENT SERVICE, DEPARTMENT OF THE INTERIOR...-Way § 250.1004 Safety equipment requirements for DOI pipelines. (a) The lessee shall ensure the...

  4. 43 CFR 2.32 - How long does DOI have to respond to my appeal?

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 43 Public Lands: Interior 1 2010-10-01 2010-10-01 false How long does DOI have to respond to my appeal? 2.32 Section 2.32 Public Lands: Interior Office of the Secretary of the Interior RECORDS AND TESTIMONY; FREEDOM OF INFORMATION ACT FOIA Appeals § 2.32 How long does DOI have to respond to my appeal?...

  5. 43 CFR 2.5 - Does DOI maintain an index of its reading room materials?

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 43 Public Lands: Interior 1 2012-10-01 2011-10-01 true Does DOI maintain an index of its reading... a FOIA Request § 2.5 Does DOI maintain an index of its reading room materials? Each bureau will maintain and make available for public inspection and copying a current subject-matter index of its...

  6. Japan Link Center (JaLC): link management and DOI assignment for Japanese electronic scholarly contents

    NASA Astrophysics Data System (ADS)

    Kato, Takafumi; Tsuchiya, Eri; Kubota, Soichi; Miyagawa, Yoshiyuki

    JST, cooperated with several national institutes, is currently developing “Japan Link Center”, which manages Japanese electronic scholarly contents (journal articles, books, dissertations etc.) in an integrated fashion using Digital Object Identifier (DOI). Japan Link Center will manage metadata and whereabouts information of the contents in the digital environment and provide domestic and international linking information, cite/cited information to activate dissemination of S&T information, furthermore, to strengthen transmission of S&T information from Japan. Japan Link Center is expected to be appointed as the 9th DOI registration agency (RA) in the world by the International DOI Foundation (IDF) this spring.

  7. STS-87 Mission Specialist Doi with EVA coordinator Laws participates in the CEIT for his mission

    NASA Technical Reports Server (NTRS)

    1997-01-01

    STS-87 Mission Specialist Takao Doi , Ph.D., of the National Space Development Agency of Japan, participates in the Crew Equipment Integration Test (CEIT) at Kennedy Space Center (KSC). Glenda Laws, the extravehicular activity (EVA) coordinator, Johnson Space Center, stands behind Dr. Doi. The CEIT gives astronauts an opportunity to get a hands-on look at the payloads with which they will be working on-orbit. STS-87 will be the fourth United States Microgravity Payload and flight of the Spartan-201 deployable satellite. During the mission, Dr. Doi will be the first Japanese astronaut to perform a spacewalk. STS- 87 is scheduled for a Nov. 19 liftoff from KSC.

  8. 41 CFR 102-75.635 - What information must the Department of the Interior (DOI) furnish eligible public agencies?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 41 Public Contracts and Property Management 3 2010-07-01 2010-07-01 false What information must the Department of the Interior (DOI) furnish eligible public agencies? 102-75.635 Section 102-75.635... the Interior (DOI) furnish eligible public agencies? Upon request, DOI must furnish eligible...

  9. 30 CFR 250.1006 - How must I decommission and take out of service a DOI pipeline?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... a DOI pipeline? 250.1006 Section 250.1006 Mineral Resources MINERALS MANAGEMENT SERVICE, DEPARTMENT... and Pipeline Rights-of-Way § 250.1006 How must I decommission and take out of service a DOI pipeline...) The table in this section lists the requirements if you take a DOI pipeline out of service: If...

  10. 41 CFR 102-75.665 - What happens after the disposal agency receives the assignment recommendation from DOI?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... disposal agency receives the assignment recommendation from DOI? 102-75.665 Section 102-75.665 Public... assignment recommendation from DOI? If, after considering other uses for the property, the disposal agency approves the assignment recommendation from DOI, it must assign the property by letter or other document...

  11. 41 CFR 102-75.670 - What responsibilities does DOI have after receiving the disposal agency's assignment letter?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... does DOI have after receiving the disposal agency's assignment letter? 102-75.670 Section 102-75.670... Property for Use As Public Park Or Recreation Areas § 102-75.670 What responsibilities does DOI have after..., the Secretary may proceed with the transfer. DOI must take all necessary actions to accomplish...

  12. 76 FR 77244 - Renewal of Information Collection; OMB Control Number 1040-0001, DOI Programmatic Clearance for...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-12-12

    ... Office of the Secretary Renewal of Information Collection; OMB Control Number 1040-0001, DOI Programmatic... comments. SUMMARY: We (Department of the Interior, DOI) plan to ask the Office of Management and Budget... you wish to email comments, the email address is Donald_Bieniewicz@ios.doi.gov . Reference...

  13. EM International. Volume 1

    SciTech Connect

    Not Available

    1993-07-01

    It is the intent of EM International to describe the Office of Environmental Restoration and Waste Management`s (EM`s) various roles and responsibilities within the international community. Cooperative agreements and programs, descriptions of projects and technologies, and synopses of visits to international sites are all highlighted in this semiannual journal. Focus on EM programs in this issue is on international collaboration in vitrification projects. Technology highlights covers: in situ sealing for contaminated sites; and remote sensors for toxic pollutants. Section on profiles of countries includes: Arctic contamination by the former Soviet Union, and EM activities with Germany--cooperative arrangements.

  14. DOI Use of AVIRIS Data in Natural Resources Management: A Technology Transfer Project Status Report

    NASA Technical Reports Server (NTRS)

    Getter, James R.; Wickland, Diane

    1998-01-01

    A meeting was held in December 1996, attended by representatives from Department of the Interior (DOI) and National Aeronautical and Space Administration (NASA) at the request of Department of the Interior Secretary, Bruce Babbitt and NASA, Administrator Director Dan Goldin, to discuss the use of hyperspectral systems and related remote sensing technologies in addressing environmental issues of environmental importance to the (DOI). It was determined that NASA/DOI Coordination be established, comprised of representatives from each agency, designated to address the environmental issues and resulting technologies. A steering committee was formed consisting of representatives from NASA Headquarters, NASA PI's from University California-Davis, University of Colorado-Boulder, University of New Hampshire and DOI Bureaus (Indian Affairs, Land Management, Reclamation, National Park Service, and US Geological Survey).

  15. DOI criticized for failing to inventory hazardous waste sites on federal lands

    SciTech Connect

    1993-11-01

    The Department of the Interior (DOI) manages approximately 440 million acres of public land across the United States, including national parks and forests, wildlife refuges, fish hatcheries, and water and hydroelectric projects. At these facilities, hazardous wastes are commonly generated through such activities as oil and gas drilling, coal mining, hydroelectric plant operation, and pesticide application. Consequently, a significant number of DOI sites are probably contaminated and thus must be identified, assessed, and remediated. 2 refs., 1 tab.

  16. Data always getting bigger -- A scalable DOI architecture for big and expanding scientific data

    DOE PAGESBeta

    Prakash, Giri; Shrestha, Biva; Younkin, Katarina; Jundt, Rolanda; Martin, Mark; Elliott, Jannean

    2016-08-31

    The Atmospheric Radiation Measurement (ARM) Data Archive established a data citation strategy based on Digital Object Identifiers (DOIs) for the ARM datasets in order to facilitate citing continuous and diverse ARM datasets in articles and other papers. This strategy eases the tracking of data provided as supplements to articles and papers. Additionally, it allows future data users and the ARM Climate Research Facility to easily locate the exact data used in various articles. Traditionally, DOIs are assigned to individual digital objects (a report or a data table), but for ARM datasets, these DOIs are assigned to an ARM data product.more » This eliminates the need for creating DOIs for numerous components of the ARM data product, in turn making it easier for users to manage and cite the ARM data with fewer DOIs. In addition, the ARM data infrastructure team, with input from scientific users, developed a citation format and an online data citation generation tool for continuous data streams. As a result, this citation format includes DOIs along with additional details such as spatial and temporal information.« less

  17. Choice of crystal surface finishing for a dual-ended readout depth-of-interaction (DOI) detector.

    PubMed

    Fan, Peng; Ma, Tianyu; Wei, Qingyang; Yao, Rutao; Liu, Yaqiang; Wang, Shi

    2016-02-01

    The objective of this study was to choose the crystal surface finishing for a dual-ended readout (DER) DOI detector. Through Monte Carlo simulations and experimental studies, we evaluated 4 crystal surface finishing options as combinations of crystal surface polishing (diffuse or specular) and reflector (diffuse or specular) options on a DER detector. We also tested one linear and one logarithm DOI calculation algorithm. The figures of merit used were DOI resolution, DOI positioning error, and energy resolution. Both the simulation and experimental results show that (1) choosing a diffuse type in either surface polishing or reflector would improve DOI resolution but degrade energy resolution; (2) crystal surface finishing with a diffuse polishing combined with a specular reflector appears a favorable candidate with a good balance of DOI and energy resolution; and (3) the linear and logarithm DOI calculation algorithms show overall comparable DOI error, and the linear algorithm was better for photon interactions near the ends of the crystal while the logarithm algorithm was better near the center. These results provide useful guidance in DER DOI detector design in choosing the crystal surface finishing and DOI calculation methods. PMID:26757857

  18. Consistent Observational and Numerical Modeling Support for Ice Sheet Forcing of DOI event 8

    NASA Astrophysics Data System (ADS)

    Lu, S.; Jackson, C.; Marchal, O.; Thompson, W.; Stocker, T.

    2008-12-01

    The Binge/Purge (B/P) hypothesis of abrupt climate change (MacAyeal, 1993a,b, Paleoceanography) suggests that an instability and periodic collapse of the Laurentide ice sheet is responsible for the observed abrupt warmings of Greenland (Dansgaard-Oeschger Interstadials or DOIs) through the influence of ice sheet meltwater on ocean circulation and its poleward heat transport. If the B/P hypothesis is correct, then one should be able to use the Greenland paleotemperature data and a climate model to infer changes in global sea level associated with the DOIs. The B/P hypothesis could then be tested by comparing the inferred sea level changes with independent reconstructions based on marine records (corals and sediments). We use stochastic inversion of a seasonal resolving climate model (Schmittner and Stocker, 1999, J. Climate), composed of a zonally averaged ocean model (Wright and Stocker, 1992, J. Geophys. Res.) coupled to an energy and moisture balance model of the atmosphere, to infer the changes in ice sheet meltwater required to explain the Greenland paleotemperature record from 39 ka to 34 ka which include DOIs 8, 7, and 6. We found a compelling consistency between modeled and reconstructed sea level changes for DOI 8 (a particularly long interstadial following Heinrich Event 4), which tends to support the B/P hypothesis. On the other hand, the large estimated uncertainties in the inversion solution and sea level reconstructions do not permit a firm test of the B/P hypothesis for DOIs 7 and 6.

  19. Nicotine attenuates DOI-induced head-twitch response in mice: implications for Tourette syndrome.

    PubMed

    Tizabi, Y; Russell, L T; Johnson, M; Darmani, N A

    2001-10-01

    Tourette syndrome (TS), a chronic neuropsychiatric disorder, is characterized by motor and vocal tics. Preliminary clinical studies indicate possible therapeutic benefits of nicotine in the treatment of Tourette's syndrome (TS). It has been proposed that twitches of the head in mice or twitches of head and shoulders in rats following administration of the selective 5HT(2A/C) agonist DOI (1-)2,5-dimethoxy-4-iodophenyl-2-aminopropane, can serve as an animal model of tics in TS. In this study, the effects of acute and chronic administration of nicotine on DOI-induced head twitch response (HTR) in male albino ICR mice were evaluated. Both acute and chronic nicotine (daily injections for 10 days) reduced the DOI-induced HTR. Moreover, chronic administration of DOI (1 mg/kg/day for 10 days) resulted in 65% increase in [125I]alpha-bungarotoxin binding in cerebellum and 41% increase in striatal [3H]cytisine binding. However, the acute inhibitory effects of nicotine were not blocked by pretreatment with the nicotinic antagonist, mecamylamine. Indeed, at higher doses, mecamylamine also reduced the DOI-induced HTR. The data suggest that both nicotine and mecamylamine may be of therapeutic potential in the treatment of some symptoms of TS. PMID:11513358

  20. Diffusion of Innovation in Long-Term Care (DOI-LTC) Measurement Battery

    PubMed Central

    McConnell, Eleanor S.; Corazzini, Kirsten N.; Lekan, Deborah; Bailey, Donald C.; Sloane, Richard; Landerman, L. Richard; Champagne, Mary T.

    2013-01-01

    Poor understanding of factors influencing integration of new practices into long-term care (LTC) hinders timely implementation of evidence-based practices (EBPs). Using the Diffusion of Innovations (DOI) framework, a new instrument measuring staff perceptions of an EBP was developed as part of a DOI-LTC battery, and tested in a cross-sectional survey of North Carolina LTC nursing personnel. Valid questionnaires were received from 95 licensed nurses and 102 certified nursing assistants (CNAs). Internal consistency reliability for five of seven subscales was acceptable (Cronbach’s alpha = .77 to .95). Perception of innovation attributes was associated with intention to adopt the new practice (licensed nurses Spearman Rho = .41–.68, p < .0001; CNAs = .26–.54, p = .05 to < .0001). The DOI-LTC battery represents a promising new approach to studying implementation of EBPs in LTC. Future work should examine its responsiveness to interventions that facilitate implementation of EBPs in LTC. PMID:21702425

  1. Characterization of stacked-crystal PET detector designs for measurement of both TOF and DOI

    NASA Astrophysics Data System (ADS)

    Schmall, Jeffrey P.; Surti, Suleman; Karp, Joel S.

    2015-05-01

    A PET detector with good timing resolution and two-level depth-of-interaction (DOI) discrimination can be constructed using a single-ended readout of scintillator stacks of Lanthanum Bromide (LaBr3), with various Cerium dopant concentrations, including pure Cerium Bromide (CeBr3). The stacked crystal geometry creates a unique signal shape for interactions occurring in each layer, which can be used to identify the DOI, while retaining the inherently good timing properties of LaBr3 and CeBr3. In this work, single pixel elements are used to optimize the choice of scintillator, coupling of layers, and type of photodetector, evaluating the performance using a fast, single-channel photomultiplier tube (PMT) and a single 4 × 4 mm2 silicon photomultiplier (SiPM). We also introduce a method to quantify and evaluate the DOI discrimination accuracy. From signal shape measurements using fast waveform sampling, we found that in addition to differences in signal rise times, between crystal layers, there were also differences in the signal fall times. A DOI accuracy of 98% was achieved using our classification method for a stacked crystal pair, consisting of a 15 mm long LaBr3(Ce:20%) crystal on top of a 15 mm long CeBr3 crystal, readout using a PMT. A DOI accuracy of 95% was measured with a stack of two, identical, 12 mm long, CeBr3 crystals. The DOI accuracy of this crystal pair was reduced to 91% when using a SiPM for readout. For the stack of two, 12 mm long, CeBr3 crystals, a coincidence timing resolution (average of timing results from the top and bottom layer) of 199 ps was measured using a PMT, and this was improved to 153 ps when using a SiPM. These results show that with stacked LaBr3/CeBr3 scintillators and fast waveform sampling nearly perfect DOI accuracy can be achieved with excellent timing resolution—timing resolution that is only minimally degraded compared to results from a single CeBr3 crystal of comparable length to the stacked crystals. The

  2. STS-87 Mission Specialist Doi and his wife pose at LC 39B

    NASA Technical Reports Server (NTRS)

    1997-01-01

    STS-87 Mission Specialist Takao Doi, Ph.D., of the National Space Development Agency of Japan poses with his wife, Hitomi Doi, in front of Kennedy Space Center's Launch Pad 39B during final prelaunch activities leading up to the scheduled Nov. 19 liftoff. The other STS-87 crew members are Commander Kevin Kregel; Pilot Steven Lindsey; Mission Specialists Kalpana Chawla, Ph.D., and Winston Scott; and Payload Specialist Leonid Kadenyuk of the National Space Agency of Ukraine. STS-87 will be the fourth flight of the United States Microgravity Payload and the Spartan- 201 deployable satellite.

  3. Characterization of stacked-crystal PET detector designs for measurement of both TOF and DOI.

    PubMed

    Schmall, Jeffrey P; Surti, Suleman; Karp, Joel S

    2015-05-01

    A PET detector with good timing resolution and two-level depth-of-interaction (DOI) discrimination can be constructed using a single-ended readout of scintillator stacks of Lanthanum Bromide (LaBr3), with various Cerium dopant concentrations, including pure Cerium Bromide (CeBr3). The stacked crystal geometry creates a unique signal shape for interactions occurring in each layer, which can be used to identify the DOI, while retaining the inherently good timing properties of LaBr3 and CeBr3. In this work, single pixel elements are used to optimize the choice of scintillator, coupling of layers, and type of photodetector, evaluating the performance using a fast, single-channel photomultiplier tube (PMT) and a single 4 × 4 mm(2) silicon photomultiplier (SiPM). We also introduce a method to quantify and evaluate the DOI discrimination accuracy. From signal shape measurements using fast waveform sampling, we found that in addition to differences in signal rise times, between crystal layers, there were also differences in the signal fall times. A DOI accuracy of 98% was achieved using our classification method for a stacked crystal pair, consisting of a 15 mm long LaBr3(Ce:20%) crystal on top of a 15 mm long CeBr3 crystal, readout using a PMT. A DOI accuracy of 95% was measured with a stack of two, identical, 12 mm long, CeBr3 crystals. The DOI accuracy of this crystal pair was reduced to 91% when using a SiPM for readout. For the stack of two, 12 mm long, CeBr3 crystals, a coincidence timing resolution (average of timing results from the top and bottom layer) of 199 ps was measured using a PMT, and this was improved to 153 ps when using a SiPM. These results show that with stacked LaBr3/CeBr3 scintillators and fast waveform sampling nearly perfect DOI accuracy can be achieved with excellent timing resolution-timing resolution that is only minimally degraded compared to results from a single CeBr3 crystal of comparable length to the stacked crystals. The

  4. Characterization of stacked-crystal PET detector designs for measurement of both TOF and DOI

    PubMed Central

    Schmall, Jeffrey P; Surti, Suleman; Karp, Joel S

    2015-01-01

    A PET detector with good timing resolution and two-level depth-of-interaction (DOI) discrimination can be constructed using a single-ended readout of scintillator stacks of Lanthanum Bromide (LaBr3), with various Cerium dopant concentrations, including pure Cerium Bromide (CeBr3). The stacked crystal geometry creates a unique signal shape for interactions occurring in each layer, which can be used to identify the DOI, while retaining the inherently good timing properties of LaBr3 and CeBr3. In this work, single pixel elements are used to optimize the choice of scintillator, coupling of layers, and type of photodetector, evaluating the performance using a fast, single-channel photomultiplier tube (PMT) and a single 4×4 mm2 silicon photomultiplier (SiPM). We also introduce a method to quantify and evaluate the DOI discrimination accuracy. From signal shape measurements using fast waveform sampling, we found that in addition to differences in signal rise times, between crystal layers, there were also differences in the signal fall times. A DOI accuracy of 98% was achieved using our classification method for a stacked crystal pair, consisting of a 15-mm long LaBr3(Ce:20%) crystal on top of a 15-mm long CeBr3 crystal, readout using a PMT. A DOI accuracy of 95% was measured with a stack of two, identical, 12-mm long, CeBr3 crystals. The DOI accuracy of this crystal pair was reduced to 91% when using a SiPM for readout. For the stack of two, 12-mm long, CeBr3 crystals, a coincidence timing resolution (average of timing results from the top and bottom layer) of 199 ps was measured using a PMT, and this was improved to 153 ps when using a SiPM. These results show that with stacked LaBr3/CeBr3 scintillators and fast waveform sampling nearly perfect DOI accuracy can be achieved with excellent timing resolution—timing resolution that is only minimally degraded compared to results from a single CeBr3 crystal of comparable length to the stacked crystals. The interface in the

  5. Data DOIs - virtues and weak points from the perspective of the data journal ESSD

    NASA Astrophysics Data System (ADS)

    Pfeiffenberger, Hans; Carlson, David

    2016-04-01

    Fundamentally, data publication seeks to provide improved access, trust and utility for data users accompanied by improved recognition for data providers. The features of persistent identifier schemes used in this context and the policies of providers of their resolver systems can greatly contribute towards these aims! Unfortunately, we also recognize situations where identifier systems undermine some of our lofty data publication aims. From our 7 years of successful experience with the data journal ESSD, we will present our practical observations as well as future requirements on the DOI-system in particular, such as: * Most scientists contributing to or drawing benefit from ESSD seem to understand the notion of published data in the sense of a static, citable entity to build on, relying on its long term availability and integrity (as is the case with journal articles), secured by DOIs. * It is still true that many data providers - individuals or projects - can not find a repository for their (type of) data which would provide a DOI (or other persistent identifier) and that many data centers and databases holding valuable data have a hard time adding DOIs as a feature of their systems for conceptual, legacy or funding reasons. * The typical evolution of many important data collections or data products - such as the Global Carbon Budget - can adequately be tracked with yearly (or less frequent) issues of dataset and data article, each having a new DOI. However, issuing a new DOI for a dataset extended in time clashes with many producers' wish to amass all references to the developing dataset under one citation (and one DOI). * Current practises with DOIs and metadata associated with DOIs need to be clarified and amended so the identifier systems can and do express and track the relationships between versions of data, addressing extensions, corrections, modifications, revisions and retractions in an unambiguous (and machine readable) manner, while also removing

  6. Digital Object Identifiers (DOI's) usage and adoption in U.S Geological Survey (USGS)

    NASA Astrophysics Data System (ADS)

    Frame, M. T.; Palanisamy, G.

    2013-12-01

    Addressing grand environmental science challenges requires unprecedented access to easily understood data that cross the breadth of temporal, spatial, and thematic scales. From a scientist's perspective, the big challenges lie in discovering the relevant data, dealing with extreme data heterogeneity, large data volumes, and converting data to information and knowledge. Historical linkages between derived products, i.e. Publications, and associated datasets has not existed in the earth science community. The USGS Core Science Analytics and Synthesis, in collaboration with DOE's Oak Ridge National Laboratory (ORNL) Mercury Consortium (funded by NASA, USGS and DOE), established a Digital Object Identifier (DOI) service for USGS data, metadata, and other media. This service is offered in partnership through the University of California Digital Library EZID service. USGS scientists, data managers, and other professionals can generate globally unique, persistent and resolvable identifiers for any kind of digital objects. Additional efforts to assign DOIs to historical data and publications have also been underway. These DOI identifiers are being used to cite data in journal articles, web-accessible datasets, and other media for distribution, integration, and in support of improved data management practices. The session will discuss the current DOI efforts within USGS, including a discussion on adoption, challenges, and future efforts necessary to improve access, reuse, sharing, and discoverability of USGS data and information.

  7. Resolving DOI Based URNs Using Squid: An Experimental System at UKOLN.

    ERIC Educational Resources Information Center

    Powell, Andy

    1998-01-01

    Describes UKOLN's (United Kingdom Office for Library and Information Networking--a national center for support in network information management in the library/information communities) experimental system that allows digital object identifiers (DOIs) encoded as uniform resource names (URNs) to be resolved on behalf of Web browsers by Squid, a…

  8. 30 CFR 250.1003 - Installation, testing, and repair requirements for DOI pipelines.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... DOI pipelines. (a)(1) Pipelines greater than 85/8 inches in diameter and installed in water depths of... exists. (b)(1) Pipelines shall be pressure tested with water at a stabilized pressure of at least 1.25... pipeline shall be pressure tested with water or processed natural gas at a minimum stabilized pressure...

  9. 30 CFR 250.1003 - Installation, testing, and repair requirements for DOI pipelines.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... DOI pipelines. (a)(1) Pipelines greater than 85/8 inches in diameter and installed in water depths of... exists. (b)(1) Pipelines shall be pressure tested with water at a stabilized pressure of at least 1.25... pipeline shall be pressure tested with water or processed natural gas at a minimum stabilized pressure...

  10. 30 CFR 250.1003 - Installation, testing, and repair requirements for DOI pipelines.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... DOI pipelines. (a)(1) Pipelines greater than 85/8 inches in diameter and installed in water depths of... exists. (b)(1) Pipelines shall be pressure tested with water at a stabilized pressure of at least 1.25... pipeline shall be pressure tested with water or processed natural gas at a minimum stabilized pressure...

  11. 30 CFR 250.1003 - Installation, testing, and repair requirements for DOI pipelines.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... for DOI pipelines. 250.1003 Section 250.1003 Mineral Resources BUREAU OF OCEAN ENERGY MANAGEMENT... pipeline may constitute a hazard to trawling operations or other uses. A trawl test or diver survey may be... determines that such items present no hazard to trawling or other operations. A protective device may be...

  12. Role of endocannabinoid and glutamatergic systems in DOI-induced head-twitch response in mice.

    PubMed

    Egashira, Nobuaki; Shirakawa, Atsunori; Okuno, Ryoko; Mishima, Kenichi; Iwasaki, Katsunori; Oishi, Ryozo; Fujiwara, Michihiro

    2011-07-01

    We previously reported that systemic administration of the endocannabinoid anandamide inhibited the head-twitches induced by the hallucinogenic drug 2,5-dimethoxy-4-iodoamphetamine (DOI) in mice, which is mediated via the activation of 5-HT(2A) receptors. Endocannabinoid and glutamatergic systems have been suggested to modulate the function of 5-HT(2A) receptors. In the present study, we further investigated the role of endocannabinoid and glutamatergic systems in DOI-induced head-twitch response in mice. An anandamide transport inhibitor AM404 (0.3-3mg/kg, i.p.), a fatty acid amide hydrolase inhibitor URB597 (0.1-10mg/kg, i.p.), a glutamate release inhibitor riluzole (0.3 and 1mg/kg, i.p.), a natural glutamate analog l-glutamylethylamide (theanine, 1 and 3mg/kg, p.o.) and an α-amino-3-hydroxy-5-methyl-4-isoxazolepropionate (AMPA) receptor antagonist NBQX (0.01-0.3mg/kg, i.p.) significantly inhibited DOI-induced head-twitch response. The AMPA receptor positive modulator aniracetam (30 or 100mg/kg, p.o.) reversed inhibition of head-twitch response by NBQX and URB597. These findings indicated that endocannabinoid and glutamatergic systems participate in the mechanism of action of DOI to induce head-twitch response. PMID:21504759

  13. The Transformation of Higher Education in Vietnam after DoiMoi: A Story of "Dualism"

    ERIC Educational Resources Information Center

    Tran, Hien

    2009-01-01

    This research was undertaken to investigate the transformation of higher education reform in Vietnam since "DoiMoi," which involves examining its rationale and practical implementation. The reform reveals an interesting picture of Vietnam's higher education system, in which two development visions--a "market-led" vision and a "socialist-oriented"…

  14. Development of GAGG depth-of-interaction (DOI) block detectors based on pulse shape analysis

    NASA Astrophysics Data System (ADS)

    Yamamoto, Seiichi; Kobayashi, Takahiro; Yeol Yeom, Jung; Morishita, Yuki; Sato, Hiroki; Endo, Takanori; Usuki, Yoshiyuki; Kamada, Kei; Yoshikawa, Akira

    2014-12-01

    A depth-of-interaction (DOI) detector is required for developing a high resolution and high sensitivity PET system. Ce-doped Gd3Al2Ga3O12 (GAGG fast: GAGG-F) is a promising scintillator for PET applications with high light output, no natural radioisotope and suitable light emission wavelength for semiconductor based photodetectors. However, no DOI detector based on pulse shape analysis with GAGG-F has been developed to date, due to the lack of appropriate scintillators of pairing. Recently a new variation of this scintillator with different Al/Ga ratios-Ce-doped Gd3Al2.6Ga2.4O12 (GAGG slow: GAGG-S), which has slower decay time was developed. The combination of GAGG-F and GAGG-S may allow us to realize high resolution DOI detectors based on pulse shape analysis. We developed and tested two GAGG phoswich DOI block detectors comprised of pixelated GAGG-F and GAGG-S scintillation crystals. One phoswich block detector comprised of 2×2×5 mm pixel that were assembled into a 5×5 matrix. The DOI block was optically coupled to a silicon photomultiplier (Si-PM) array (Hamamatsu MPPC S11064-050P) with a 2-mm thick light guide. The other phoswich block detector comprised of 0.5×0.5×5 mm (GAGG-F) and 0.5×0.5×6 mm3 (GAGG-S) pixels that were assembled into a 20×20 matrix. The DOI block was also optically coupled to the same Si-PM array with a 2-mm thick light guide. In the block detector of 2-mm crystal pixels (5×5 matrix), the 2-dimensional histogram revealed excellent separation with an average energy resolution of 14.1% for 662-keV gamma photons. The pulse shape spectrum displayed good separation with a peak-to-valley ratio of 8.7. In the block detector that used 0.5-mm crystal pixels (20×20 matrix), the 2-dimensional histogram also showed good separation with energy resolution of 27.5% for the 662-keV gamma photons. The pulse shape spectrum displayed good separation with a peak-to-valley ratio of 6.5. These results indicate that phoswich DOI detectors with the two

  15. Development of prototype PET scanner using dual-sided readout DOI-PET modules

    NASA Astrophysics Data System (ADS)

    Fujita, T.; Kataoka, J.; Kishimoto, A.; Kurei, Y.; Nishiyama, T.; Ohshima, T.; Taya, T.

    2014-12-01

    In our previous work, we proposed a novel design for a gamma-ray detector module capable of measuring the depth of interaction (DOI). In this paper, we further developed DOI-PET detector modules and a data acquisition system, and evaluated its performance. Each detector module was composed of a 3-D scintillator array and two large-area monolithic Multi-Pixel Photon Counter (MPPC) arrays coupled to both ends of the 3-D scintillator array, leading to only 8-ch signal outputs from a module. The 3-D scintillator array was composed of 9 × 9 × 7 matrices of 1.0 × 1.0 × 3.0 mm3 Ce:GAGG crystals. The detector module showed good energy resolution of 10.6% as measured at 511 keV and a high average peak to valley ratio higher than 8 for each pixel crystal identified in the X-Y-Z directions. Moreover, we evaluated the spatial resolution of a virtual 18-ch PET gantry simulated by using two detector modules that were flexibly controlled using both the X-stage and θ-stage in 20-degree steps. By measuring a 22Na point source (0.25 mm in diameter), we showed that spatial resolution substantially degrades from 1.0 mm to 7.8 mm (FWHM; as measured at 0 mm and 28 mm off-center) with a non-DOI configuration, whereas the corresponding values for the DOI configuration were 0.9 mm and 1.5 mm, respectively (FWHM; as measured at 0 mm and 28 mm off-center). This preliminary study confirms that our DOI-PET module is useful for future high spatial resolution and compact small-animal PET scanners without radial image distortions at the peripheral regions of the field of view (FOV).

  16. 30 CFR 250.1006 - How must I decommission and take out of service a DOI pipeline?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... a DOI pipeline? 250.1006 Section 250.1006 Mineral Resources BUREAU OF SAFETY AND ENVIRONMENTAL... SHELF Pipelines and Pipeline Rights-of-Way § 250.1006 How must I decommission and take out of service a DOI pipeline? (a) The requirements for decommissioning pipelines are listed in § 250.1750...

  17. 30 CFR 250.1006 - How must I decommission and take out of service a DOI pipeline?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... a DOI pipeline? 250.1006 Section 250.1006 Mineral Resources BUREAU OF SAFETY AND ENVIRONMENTAL... SHELF Pipelines and Pipeline Rights-of-Way § 250.1006 How must I decommission and take out of service a DOI pipeline? (a) The requirements for decommissioning pipelines are listed in § 250.1750...

  18. 30 CFR 250.1006 - How must I decommission and take out of service a DOI pipeline?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... a DOI pipeline? 250.1006 Section 250.1006 Mineral Resources BUREAU OF SAFETY AND ENVIRONMENTAL... SHELF Pipelines and Pipeline Rights-of-Way § 250.1006 How must I decommission and take out of service a DOI pipeline? (a) The requirements for decommissioning pipelines are listed in § 250.1750...

  19. 30 CFR 250.1006 - How must I decommission and take out of service a DOI pipeline?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... a DOI pipeline? 250.1006 Section 250.1006 Mineral Resources BUREAU OF OCEAN ENERGY MANAGEMENT... OUTER CONTINENTAL SHELF Pipelines and Pipeline Rights-of-Way § 250.1006 How must I decommission and take out of service a DOI pipeline? (a) The requirements for decommissioning pipelines are listed in §...

  20. 25 CFR 900.208 - How are non-medical related tort claims and lawsuits filed for DOI?

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 25 Indians 2 2010-04-01 2010-04-01 false How are non-medical related tort claims and lawsuits filed for DOI? 900.208 Section 900.208 Indians BUREAU OF INDIAN AFFAIRS, DEPARTMENT OF THE INTERIOR, AND... Related Claims § 900.208 How are non-medical related tort claims and lawsuits filed for DOI?...

  1. Efficient system modeling for a small animal PET scanner with tapered DOI detectors

    NASA Astrophysics Data System (ADS)

    Zhang, Mengxi; Zhou, Jian; Yang, Yongfeng; Rodríguez-Villafuerte, Mercedes; Qi, Jinyi

    2016-01-01

    A prototype small animal positron emission tomography (PET) scanner for mouse brain imaging has been developed at UC Davis. The new scanner uses tapered detector arrays with depth of interaction (DOI) measurement. In this paper, we present an efficient system model for the tapered PET scanner using matrix factorization and a virtual scanner geometry. The factored system matrix mainly consists of two components: a sinogram blurring matrix and a geometrical matrix. The geometric matrix is based on a virtual scanner geometry. The sinogram blurring matrix is estimated by matrix factorization. We investigate the performance of different virtual scanner geometries. Both simulation study and real data experiments are performed in the fully 3D mode to study the image quality under different system models. The results indicate that the proposed matrix factorization can maintain image quality while substantially reduce the image reconstruction time and system matrix storage cost. The proposed method can be also applied to other PET scanners with DOI measurement.

  2. Relaxation spectra of binary blends: Extension of the Doi-Edwards theory

    NASA Astrophysics Data System (ADS)

    Tchesnokov, M. A.; Molenaar, J.; Slot, J. J. M.; Stepanyan, R.

    2007-10-01

    A molecular model is presented which allows the calculation of the stress relaxation function G for binary blends consisting of two monodisperse samples with arbitrary molecular weights. It extends the Doi-Edwards reptation theory (Doi M. and Edwards S. F., The Theory of Polymer Dynamics (Oxford Press, New York) 1986) to highly polydisperse melts by including constraint release (CR) and thermal fluctuations (CLF), yet making use of the same input parameters. The model reveals an explicit nonlinear dependence of CR frequency in the blend on the blend's molecular weight distribution (MWD). It provides an alternative way to quantify polydisperse systems compared to the widely used "double-reptation" theories. The results of the present model are in a good agreement with the experimental data given in Rubinstein M. and Colby R. H., J. Chem. Phys., 89 (1988) 5291.

  3. DOI Climate Science Centers--Regional science to address management priorities

    USGS Publications Warehouse

    O'Malley, Robin

    2012-01-01

    Our Nation's lands, waters, and ecosystems and the living and cultural resources they contain face myriad challenges from invasive species, the effects of changing land and water use, habitat fragmentation and degradation, and other influences. These challenges are compounded by increasing influences from a changing climate—higher temperatures, increasing droughts, floods, and wildfires, and overall increasing variability in weather and climate. The Department of the Interior (DOI) has established eight regional Climate Science Centers (CSC) (fig. 1) that will provide scientific information and tools to natural and cultural resource managers as they plan for conserving these resources in a changing world. The U.S. Geological Survey (USGS) National Climate Change and Wildlife Science Center (NCCWSC) is managing the CSCs on behalf of the DOI.

  4. DOI Determination by Rise Time Discrimination in Single-Ended Readout for TOF PET Imaging

    PubMed Central

    Wiener, R.I.; Surti, S.; Karp, J.S.

    2013-01-01

    Clinical TOF PET systems achieve detection efficiency using thick crystals, typically of thickness 2–3cm. The resulting dispersion in interaction depths degrades spatial resolution for increasing radial positions due to parallax error. Furthermore, interaction depth dispersion results in time pickoff dispersion and thus in degraded timing resolution, and is therefore of added concern in TOF scanners. Using fast signal digitization, we characterize the timing performance, pulse shape and light output of LaBr3:Ce, CeBr3 and LYSO. Coincidence timing resolution is shown to degrade by ~50ps/cm for scintillator pixels of constant cross section and increasing length. By controlling irradiation depth in a scintillator pixel, we show that DOI-dependence of time pickoff is a significant factor in the loss of timing performance in thick detectors. Using the correlated DOI-dependence of time pickoff and charge collection, we apply a charge-based correction to the time pickoff, obtaining improved coincidence timing resolution of <200ps for a uniform 4×4×30mm3 LaBr3 pixel. In order to obtain both DOI identification and improved timing resolution, we design a two layer LaBr3[5%Ce]/LaBr3[30%Ce] detector of total size 4×4×30mm3, exploiting the dependence of scintillator rise time on [Ce] in LaBr3:Ce. Using signal rise time to determine interaction layer, excellent interaction layer discrimination is achieved, while maintaining coincidence timing resolution of <250ps and energy resolution <7% using a R4998 PMT. Excellent layer separation and timing performance is measured with several other commercially-available TOF photodetectors, demonstrating the practicality of this design. These results indicate the feasibility of rise time discrimination as a technique for measuring event DOI while maintaining sensitivity, timing and energy performance, in a well-known detector architecture. PMID:24403611

  5. emGain: Determination of EM gain of CCD

    NASA Astrophysics Data System (ADS)

    Daigle, Olivier; Carignan, Claude; Blais-Ouellette, Sebastien

    2012-01-01

    The determination of the EM gain of the CCD is best done by fitting the histogram of many low-light frames. Typically, the dark+CIC noise of a 30ms frame itself is a sufficient amount of signal to determine accurately the EM gain with about 200 512x512 frames. The IDL code emGain takes as an input a cube of frames and fit the histogram of all the pixels with the EM stage output probability function. The function returns the EM gain of the frames as well as the read-out noise and the mean signal level of the frames.

  6. 41 CFR 102-75.640 - When must DOI notify the disposal agency that an eligible applicant is interested in acquiring...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 41 Public Contracts and Property Management 3 2010-07-01 2010-07-01 false When must DOI notify the... Disposal Property for Use As Public Park Or Recreation Areas § 102-75.640 When must DOI notify the disposal agency that an eligible applicant is interested in acquiring the property? DOI must notify the...

  7. 41 CFR 102-75.660 - What happens if DOI does not approve any applications or does not submit an assignment...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 41 Public Contracts and Property Management 3 2010-07-01 2010-07-01 false What happens if DOI does... Disposal Property for Use As Public Park Or Recreation Areas § 102-75.660 What happens if DOI does not approve any applications or does not submit an assignment recommendation? If DOI does not approve...

  8. Estudo comparativo entre estrelas centrais de nebulosas planetárias deficientes em hidrogênio

    NASA Astrophysics Data System (ADS)

    Marcolino, W. L. F.; de Araújo, F. X.

    2003-08-01

    Apresentamos neste trabalho o resultado de um estudo das principais características espectrais das estrelas centrais de nebulosas planetárias (ECNP) deficientes em hidrogênio. A origem e a evolução dessas estrelas ainda constitui um problema em aberto na evolução estelar. Geralmente esses objetos são divididos em [WCE], [WCL] e [WELS]. Os tipos [WCE] e [WCL] apresentam um espectro típico de uma estrela Wolf-Rayet carbonada de população I e as [WELS] apresentam linhas fracas de carbono e oxigênio em emissão. Existem evidências que apontam a seguinte sequência evolutiva : [WCL] = > [WCE] = > [WELS] = > PG 1159 (pré anã-branca). No entanto, tal cenário apresenta falhas como por exemplo a falta de ECNP entre os tipos [WCL] e [WCE]. Baseados em uma amostra de 24 objetos obtida no telescópio de 1.52m em La Silla, Chile (acordo ESO/ON), ao longo do ano 2000, apresentamos os resultados da comparação das larguras equivalentes de diversas linhas relevantes entre os tipos [WCL], [WCE] e [WELS]. Verificamos que nossos dados estão de acordo com a sequência evolutiva. Baseado nas linhas de C IV, conseguimos dividir pela primeira vez as [WELS] em dois grupos principais. Além disso, os dados reforçam a afirmação de que as [WCE] são as estrelas que possuem a maior temperatura entre as ECNP deficientes em hidrogênio. Discutimos ainda, a escassez de dados disponíveis na literatura e a necessidade da obtenção de parametros físicos para estes objetos.

  9. Use of internal scintillator radioactivity to calibrate DOI function of a PET detector with a dual-ended-scintillator readout

    SciTech Connect

    Bircher, Chad; Shao Yiping

    2012-02-15

    Purpose: Positron emission tomography (PET) detectors that use a dual-ended-scintillator readout to measure depth-of-interaction (DOI) must have an accurate DOI function to provide the relationship between DOI and signal ratios to be used for detector calibration and recalibration. In a previous study, the authors used a novel and simple method to accurately and quickly measure DOI function by irradiating the detector with an external uniform flood source; however, as a practical concern, implementing external uniform flood sources in an assembled PET system is technically challenging and expensive. In the current study, therefore, the authors investigated whether the same method could be used to acquire DOI function from scintillator-generated (i.e., internal) radiation. The authors also developed a method for calibrating the energy scale necessary to select the events within the desired energy window. Methods: The authors measured the DOI function of a PET detector with lutetium yttrium orthosilicate (LYSO) scintillators. Radiation events originating from the scintillators' internal Lu-176 beta decay were used to measure DOI functions which were then compared with those measured from both an external uniform flood source and an electronically collimated external point source. The authors conducted these studies with several scintillators of differing geometries (1.5 x 1.5 and 2.0 x 2.0 mm{sup 2} cross-section area and 20, 30, and 40 mm length) and various surface finishes (mirror-finishing, saw-cut rough, and other finishes in between), and in a prototype array. Results: All measured results using internal and external radiation sources showed excellent agreement in DOI function measurement. The mean difference among DOI values for all scintillators measured from internal and external radiation sources was less than 1.0 mm for different scintillator geometries and various surface finishes. Conclusions: The internal radioactivity of LYSO scintillators can be used

  10. 10 years of data publication with Digital Object Identifiers (DOI) at the World Data Center for Climate (WDCC)

    NASA Astrophysics Data System (ADS)

    Stockhause, Martina; Lautenschlager, Michael; Höck, Heinke; Toussaint, Frank

    2015-04-01

    The World Data Center for Climate (WDCC) has been Data DOI publication agency for 10 years. Before issuing the first Data DOI, five years were spent on the development of a concept out of the idea to make scientific data citable. Apart from the unique and persistent identification of data objects, questions e.g. about the organizational structure including the roles of libraries and data centers, cost models, data quality, and the granularity of data publications were targeted in this pre-phase. The first Data DOI publication system was developed within the German project 'std_doi' (Scientific and Technical Data DOI) funded by the German Research Foundation (DFG). The German National Library of Science and Technology (TIB) acted as DOI Registration Agency and the data centers PANGAEA, GFZ and WDCC as publication agencies and long-term data archives. The first publication of scientific data came from WDCC in March 2004 (doi:10.1594/WDCC/EH4_OPYC_SRES_A2). About five years after the first data publications, in December 2009, the international organization DataCite was formed, leading to several organizational as well as technical changes affecting WDCC's scientific data publication process. Recently, WDCC became the data publisher for the decentrally disseminated data of the project CMIP5 (Climate Model Intercomparison Project Phase 5) and participated in the development of the data publication system 'atarrabi', requiring several additions and changes in WDCC's established data publication procedure. The challenges for the future of WDCC's scientific data publication lie in the connections of data to other DOI objects like scientific publications or to other persistent identifiers such as e.g. ORCID for persons or EPIC Handles for changeable data objects in the scientific workflow. Issues like data quality and data granularity have not been solved for the time being but are still under investigation.

  11. [2D imaging simulations of a small animal PET scanner with DOI measurement: jPET-RD.].

    PubMed

    Yamaya, Taiga; Kitamura, Keishi; Hagiwara, Naoki; Obi, Takashi; Hasegawa, Tomoyuki; Yoshida, Eiji; Tsuda, Tomoaki; Inadama, Naoko; Wada, Yasuhiro; Murayama, Hideo

    2005-01-01

    We present a preliminary study on the design of a high sensitivity small animal DOI-PET scanner: jPET-RD (for Rodents with DOI detectors), which will contribute to molecular imaging. The 4-layer DOI block detector for the jPET-RD that consists of scintillation crystals (1.4 mm x 1.4 mm x 4.5 mm) and a flat panel position-sensitive photomultiplier tube (52 mm x 52 mm) was previously proposed. In this paper, we investigate imaging performance of the jPET-RD through numerical simulations. The scanner has a hexagonal geometry with a small diameter and a large axial aperture. Therefore DOI information is expected to improve resolution uniformity in the whole field of view (FOV). We simulate the scanner for various parameters of the number of DOI channels and the crystal length. Simulated data are reconstructed using the maximum likelihood expectation maximization with accurate system modeling. The trade-off results between background noise and spatial resolution show that only shortening the length of crystal does not improve the trade-off at all, and that 4-layer DOI information improves uniformity of spatial resolution in the whole FOV. Excellent performance of the jPET-RD can be expected based on the numerical simulation results. PMID:15961924

  12. Sensitivity booster for DOI-PET scanner by utilizing Compton scattering events between detector blocks

    NASA Astrophysics Data System (ADS)

    Yoshida, Eiji; Tashima, Hideaki; Yamaya, Taiga

    2014-11-01

    In a conventional PET scanner, coincidence events are measured with a limited energy window for detection of photoelectric events in order to reject Compton scatter events that occur in a patient, but Compton scatter events caused in detector crystals are also rejected. Scatter events within the patient causes scatter coincidences, but inter crystal scattering (ICS) events have useful information for determining an activity distribution. Some researchers have reported the feasibility of PET scanners based on a Compton camera for tracing ICS into the detector. However, these scanners require expensive semiconductor detectors for high-energy resolution. In the Anger-type block detector, single photons interacting with multiple detectors can be obtained for each interacting position and complete information can be gotten just as for photoelectric events in the single detector. ICS events in the single detector have been used to get coincidence, but single photons interacting with multiple detectors have not been used to get coincidence. In this work, we evaluated effect of sensitivity improvement using Compton kinetics in several types of DOI-PET scanners. The proposed method promises to improve the sensitivity using coincidence events of single photons interacting with multiple detectors, which are identified as the first interaction (FI). FI estimation accuracy can be improved to determine FI validity from the correlation between Compton scatter angles calculated on the coincidence line-of-response. We simulated an animal PET scanner consisting of 42 detectors. Each detector block consists of three types of scintillator crystals (LSO, GSO and GAGG). After the simulation, coincidence events are added as information for several depth-of-interaction (DOI) resolutions. From the simulation results, we concluded the proposed method promises to improve the sensitivity considerably when effective atomic number of a scintillator is low. Also, we showed that FI estimate

  13. STS-87 Mission Specialist Doi addresses the media at the SLF

    NASA Technical Reports Server (NTRS)

    1997-01-01

    As STS-87 Commander Kevin Kregel looks on, Mission Specialist Takao Doi, Ph.D., of the National Space Development Agency of Japan addresses members of the press and media at Kennedy Space Center's Shuttle Landing Facility after arriving for the final prelaunch activities leading up to the scheduled Nov. 19 liftoff. Other STS-87 crew members not pictured are Pilot Steven Lindsey; Mission Specialists Kalpana Chawla, Ph.D., and Winston Scott; and Payload Specialist Leonid Kadenyuk of the National Space Agency of Ukraine. STS-87 will be the fourth flight of the United States Microgravity Payload and the Spartan-201 deployable satellite.

  14. The EM Earthquake Precursor

    NASA Astrophysics Data System (ADS)

    Jones, K. B., II; Saxton, P. T.

    2013-12-01

    Many attempts have been made to determine a sound forecasting method regarding earthquakes and warn the public in turn. Presently, the animal kingdom leads the precursor list alluding to a transmission related source. By applying the animal-based model to an electromagnetic (EM) wave model, various hypotheses were formed, but the most interesting one required the use of a magnetometer with a differing design and geometry. To date, numerous, high-end magnetometers have been in use in close proximity to fault zones for potential earthquake forecasting; however, something is still amiss. The problem still resides with what exactly is forecastable and the investigating direction of EM. After the 1989 Loma Prieta Earthquake, American earthquake investigators predetermined magnetometer use and a minimum earthquake magnitude necessary for EM detection. This action was set in motion, due to the extensive damage incurred and public outrage concerning earthquake forecasting; however, the magnetometers employed, grounded or buried, are completely subject to static and electric fields and have yet to correlate to an identifiable precursor. Secondly, there is neither a networked array for finding any epicentral locations, nor have there been any attempts to find even one. This methodology needs dismissal, because it is overly complicated, subject to continuous change, and provides no response time. As for the minimum magnitude threshold, which was set at M5, this is simply higher than what modern technological advances have gained. Detection can now be achieved at approximately M1, which greatly improves forecasting chances. A propagating precursor has now been detected in both the field and laboratory. Field antenna testing conducted outside the NE Texas town of Timpson in February, 2013, detected three strong EM sources along with numerous weaker signals. The antenna had mobility, and observations were noted for recurrence, duration, and frequency response. Next, two

  15. A novel method to calibrate DOI function of a PET detector with a dual-ended-scintillator readout.

    PubMed

    Shao, Yiping; Yao, Rutao; Ma, Tianyu

    2008-12-01

    The detection of depth-of-interaction (DOI) is a critical detector capability to improve the PET spatial resolution uniformity across the field-of-view and will significantly enhance, in particular, small bore system performance for brain, breast, and small animal imaging. One promising technique of DOI detection is to use dual-ended-scintillator readout that uses two photon sensors to detect scintillation light from both ends of a scintillator array and estimate DOI based on the ratio of signals (similar to Anger logic). This approach needs a careful DOI function calibration to establish accurate relationship between DOI and signal ratios, and to recalibrate if the detection condition is shifted due to the drift of sensor gain, bias variations, or degraded optical coupling, etc. However, the current calibration method that uses coincident events to locate interaction positions inside a single scintillator crystal has severe drawbacks, such as complicated setup, long and repetitive measurements, and being prone to errors from various possible misalignments among the source and detector components. This method is also not practically suitable to calibrate multiple DOI functions of a crystal array. To solve these problems, a new method has been developed that requires only a uniform flood source to irradiate a crystal array without the need to locate the interaction positions, and calculates DOI functions based solely on the uniform probability distribution of interactions over DOI positions without knowledge or assumption of detector responses. Simulation and experiment have been studied to validate the new method, and the results show that the new method, with a simple setup and one single measurement, can provide consistent and accurate DOI functions for the entire array of multiple scintillator crystals. This will enable an accurate, simple, and practical DOI function calibration for the PET detectors based on the design of dual-ended-scintillator readout. In

  16. A novel method to calibrate DOI function of a PET detector with a dual-ended-scintillator readout

    SciTech Connect

    Shao Yiping; Yao Rutao; Ma Tianyu

    2008-12-15

    The detection of depth-of-interaction (DOI) is a critical detector capability to improve the PET spatial resolution uniformity across the field-of-view and will significantly enhance, in particular, small bore system performance for brain, breast, and small animal imaging. One promising technique of DOI detection is to use dual-ended-scintillator readout that uses two photon sensors to detect scintillation light from both ends of a scintillator array and estimate DOI based on the ratio of signals (similar to Anger logic). This approach needs a careful DOI function calibration to establish accurate relationship between DOI and signal ratios, and to recalibrate if the detection condition is shifted due to the drift of sensor gain, bias variations, or degraded optical coupling, etc. However, the current calibration method that uses coincident events to locate interaction positions inside a single scintillator crystal has severe drawbacks, such as complicated setup, long and repetitive measurements, and being prone to errors from various possible misalignments among the source and detector components. This method is also not practically suitable to calibrate multiple DOI functions of a crystal array. To solve these problems, a new method has been developed that requires only a uniform flood source to irradiate a crystal array without the need to locate the interaction positions, and calculates DOI functions based solely on the uniform probability distribution of interactions over DOI positions without knowledge or assumption of detector responses. Simulation and experiment have been studied to validate the new method, and the results show that the new method, with a simple setup and one single measurement, can provide consistent and accurate DOI functions for the entire array of multiple scintillator crystals. This will enable an accurate, simple, and practical DOI function calibration for the PET detectors based on the design of dual-ended-scintillator readout. In

  17. Bioterrorism awareness for EMS.

    PubMed

    Patrick, Richard W

    2004-04-01

    It is important to understand that the issues surrounding bioterrorism and all weapons of mass destruction are complex. In an effort to enhance response to such events, EMS should handle all incidents from the perspective of an all-hazards approach. Prevention, preparation, response and recovery are essential to the safe mitigation of all incidents. Organizations must be prepared. Plan now for a safer tomorrow. Your personnel and communities depend on you. PMID:15131906

  18. Design of a High Resolution, Monolithic Crystal, PET/MRI Detector with DOI Positioning Capability.

    PubMed

    Miyaoka, Robert S; Li, Xiaoli; Lockhart, Cate; Lewellen, Tom K

    2008-10-01

    We report on a high resolution, monolithic crystal PET detector design concept that provides depth of interaction (DOI) positioning within the crystal and is compatible for operation in a MRI scanner to support multimodal anatomic and functional imaging. Our design utilizes a novel sensor on the entrance surface (SES) approach combined with a maximum likelihood positioning algorithm. The sensor will be a two-dimensional array of micro-pixel avalanche photodiodes (MAPD). MAPDs are a new type of solid-state photodetector with Geiger mode operation that can provide signal gain similar to a photomltipiler tube (PMT). In addition, they can be operated in high magnetic fields to support PET/MR imaging. Utilizing a multi-step simulation process, we determined the intrinsic spatial resolution characteristics for a variety of detector configurations. The crystal was always modeled as a 48.8 mm by 48.8 mm by 15 mm monolithic slab of a lutetium-based scintillator. The SES design was evaluated via simulation for three different two-dimensional MAPD array sizes: 8×8 with 5.8×5.8 mm(2) pads; 12×12 with 3.8×3.8 mm(2) pads; and 16×16 with 2.8×2.8 mm(2) pads. To reduce the number of signal channels row-column summing readout was explored for the 12×12 and 16×16 channel array devices. The intrinsic spatial resolution for the 8×8 MAPD array is 0.88 mm FWHM in X and Y, and 1.83 mm FWHM in Z (i.e., DOI). Comparing the results versus using a conventional design with the photosensors on the backside of the crystal, an average improvement of ~24% in X and Y and 20% in Z is achieved. The X, Y intrinsic spatial resolution improved to 0.66 mm and 0.65 mm FWHM for the 12×12 and 16×16 MAPDs using row-column readout. Using the 12×12 and 16×16 arrays also led to a slight improvement in the DOI positioning accuracy. PMID:20607144

  19. Transient radiation effects in D.O.I. optical materials: Schott filter glass

    SciTech Connect

    Simmons-Potter, K.

    1998-07-01

    Department of Energy and Defense Programs systems are becoming increasingly reliant on the use of optical technologies that must perform under a range of ionizing radiation environments. In particular, the radiation response of materials under consideration for applications in direct optical initiation (D.O.I.) schemes must be well characterized. In this report, transient radiation effects observed in Schott filter glass S-7010 are characterized. Under gamma exposure with 2 MeV photons in a 20--30 nsec pulse, the authors observe strong initial induced fluorescence in the red region of the spectrum followed by significant induced absorption over the same spectral region. Peak induced absorption coefficients of 0.113 cm{sup {minus}1} and 0.088 cm{sup {minus}1} were calculated at 800 nm and 660 nm respectively.

  20. Zygomycetes From Herbivore Dung in the Ecological Reserve of Dois IrmÃOs, Northeast Brazil

    PubMed Central

    de Azevedo Santiago, André Luiz Cabral Monteiro; Botelho Trufem, Sandra Farto; Malosso, Elaine; dos Santos, Paulo Jorge Parreira; de Queiroz Cavalcanti, Maria Auxiliadora

    2011-01-01

    Thirty-eight taxa of Zygomycetes distributed in 15 genera were recorded from tapir (Tapirus terrestris), camel (Camelus bactrianus), horse (Equus caballus), deer (Cervus elaphus), agouti (Dasyprocta aguti), donkey (Equus asinus), llama (Llama glama) and waterbuck (Kobus ellipsiprymnus) dung collected at the Reserva Ecológica de Dois Irmãos located in Recife, State of Pernambuco, Northeast Brazil. The samples were collected on a monthly basis from June 2005 to May 2006, taken to the laboratory and incubated in moist chambers. Higher number of taxa was observed in the excrements of tapir, followed by deer and donkey. The highest number of species was detected for Mucor, followed by Pilobolus. Statistical analyses showed significant differences in richness of Zygomycetes taxa between the herbivore dung types. Differences of species composition, however, were weak. Seasonality influenced the Zygomycetes species composition but not its richness. Variations in taxa composition between ruminants and non-ruminants dung were non significant. PMID:24031609

  1. Zygomycetes From Herbivore Dung in the Ecological Reserve of Dois IrmÃOs, Northeast Brazil.

    PubMed

    de Azevedo Santiago, André Luiz Cabral Monteiro; Botelho Trufem, Sandra Farto; Malosso, Elaine; Dos Santos, Paulo Jorge Parreira; de Queiroz Cavalcanti, Maria Auxiliadora

    2011-01-01

    Thirty-eight taxa of Zygomycetes distributed in 15 genera were recorded from tapir (Tapirus terrestris), camel (Camelus bactrianus), horse (Equus caballus), deer (Cervus elaphus), agouti (Dasyprocta aguti), donkey (Equus asinus), llama (Llama glama) and waterbuck (Kobus ellipsiprymnus) dung collected at the Reserva Ecológica de Dois Irmãos located in Recife, State of Pernambuco, Northeast Brazil. The samples were collected on a monthly basis from June 2005 to May 2006, taken to the laboratory and incubated in moist chambers. Higher number of taxa was observed in the excrements of tapir, followed by deer and donkey. The highest number of species was detected for Mucor, followed by Pilobolus. Statistical analyses showed significant differences in richness of Zygomycetes taxa between the herbivore dung types. Differences of species composition, however, were weak. Seasonality influenced the Zygomycetes species composition but not its richness. Variations in taxa composition between ruminants and non-ruminants dung were non significant. PMID:24031609

  2. Re-using the DataCite Metadata Store as DOI registration proxy and IGSN registry

    NASA Astrophysics Data System (ADS)

    Klump, J.; Ulbricht, D.

    2012-12-01

    Currently a lot of work is done to stimulate the reuse of data. In joint efforts research institutions establish infrastructure to facilitate the publication of scientific datasets. To create a citable reference, these datasets must be tagged with persistent identifiers (DOIs) and described with metadata. As most data in the geosciences are derived from samples, it is crucial to be able to uniquely identify the samples from which a set of data were derived. Incomplete documentation of samples in publications, use of ambiguous sample names are major obstacles for synthesis studies and re-use of data. Access to samples for re-analysis and re-appraisal is limited due to the lack of a central catalogue that allows finding a sample's archiving location. The International Geo Sample Number (IGSN) [1] provides solutions to the questions of unique sample identification and discovery. Use of the IGSN in digital data systems allows building linkages between the digital representation of samples in sample registries, e.g. SESAR [2], and their related data in the literature and in web accessible digital data repositories. DataCite recently decided to publish their metadata store (DataCite MDS) and accompanying software online [3]. The DataCite software allows registration of handles, deposition of metadata in an XML format, it offers a search interface, and is able to disseminate metadata via OAI-PMH. Its, REST interface allows an easy integration into institutional data work flows. For our applications at GFZ Potsdam we modified the DataCite MDS software for reuse it in two different contexts: as the DOIDB web service for data publications and as the IGSN registry web service for the registration of geological samples. The DOIDB acts as a proxy service to the DataCite Metadata Store and uses its REST-Interface for registration of DataCite DOI and associated DOI metadata. Metadata can be deposited in the DataCite or NASA DIF schema. Both schemata can be disseminated via OAI

  3. STS-87 M.S. Doi and Chawla and P.S. Kadenyuk in slidewire basket

    NASA Technical Reports Server (NTRS)

    1997-01-01

    The crew of the STS-87 mission, scheduled for launch Nov. 19 aboard the Space Shuttle Columbia from pad 39B at Kennedy Space Center (KSC), participates in the Terminal Countdown Demonstration Test (TCDT) at KSC. Testing a slide wire basket that is part of the pads emergency egress system are, from left, Mission Specialist Takao Doi, Ph.D., of the National Space Development Agency of Japan; Payload Specialist Leonid Kadenyuk of the National Space Agency of Ukraine (NSAU); and Mission Specialist Kalpana Chawla, Ph.D. The TCDT is held at KSC prior to each Space Shuttle flight providing the crew of each mission opportunities to participate in simulated countdown activities. The TCDT ends with a mock launch countdown culminating in a simulated main engine cut-off. The crew also spends time undergoing emergency egress training exercises at the pad and has an opportunity to view and inspect the payloads in the orbiter's payload bay.

  4. Effects of the serotonin agonists 8-OH-DPAT, buspirone, and DOI on water maze performance.

    PubMed

    Kant, G J; Wylie, R M; Chu, K; Ghosh, S

    1998-03-01

    We have previously reported that the serotonin 5-HT1A agonist 8-OH-DPAT and the 5-HT2c agonist TFMPP impair performance on a water maze. In the present report we extended those studies by examining a second 5-HT1A agonist, buspirone, to see whether its effects paralleled those of 8-OH-DPAT, and by testing the effects of the 5-HT2 agonist DOI. Unlike the open pool Morris water maze, the maze used in these experiments has alleys and doorways. The maze can be easily reconfigured to present rats with both previously learned or new maze challenges. Performance is assessed by time to reach the maze exit platform and the number of wrong doorways entered (errors). At doses that did not affect performance in a previously learned maze, the 5-HT1A agonists 8-OH-DPAT (0.1 mg/kg) and buspirone (1 mg/kg) slowed acquisition of a new maze configuration as measured by both swim time to the exit platform and errors committed. A higher dose of buspirone (10 mg/kg) completely blocked acquisition of a novel maze. In contrast. DOI slowed performance as assessed by swim time on both a well-learned maze as well as acquisition of a new maze, but did not affect error rate on either task, suggesting that this 5-HT2 agonist impaired performance by depressing motor activity. These experiments demonstrate that serotonin agonists, especially the 5-HT1A subtype, can impair learning. PMID:9512079

  5. Enhanced defect of interest [DOI] monitoring by utilizing sensitive inspection and ADRTrue SEM review

    NASA Astrophysics Data System (ADS)

    Kirsch, Remo; Zeiske, Ulrich; Shabtay, Saar; Beyer, Mirko; Yerushalmi, Liran; Goshen, Oren

    2011-03-01

    As semiconductor process design rules continue to shrink, the ability of optical inspection tools to separate between true defects and nuisance becomes more and more difficult. Therefore, monitoring Defect of Interest (DOI) become a real challenge (Figure 1). This phenomenon occurs due to the lower signal received from real defects while noise levels remain almost the same, resulting in inspection high nuisance rate, which jeopardizes the ability to provide a meaningful, true defect Pareto. A non-representative defect Pareto creates a real challenge to a reliable process monitoring (Figure 4). Traditionally, inspection tool recipes were optimized to keep data load at a manageable level and provide defect maps with ~10% nuisance rate, but as defects of interest get smaller with design rule shrinkage, this requirement results in a painful compromise in detection sensitivity. The inspection is usually followed by defect review and classification using scanning electron microscope (SEM), the classification done manually and it is performed on a small sample of the inspection defect map due to time and manual resources limitations. Sample is usually 50~60 randomly selected locations, review is performed manually most of the times, and manual classification is performed for all the reviewed locations. In the approach described in this paper, the inspection tool recipe is optimized for sensitivity rather than low nuisance rate (i.e. detect all DOI with compromising on a higher nuisance rate). Inspection results with high nuisance rate introduce new challenges for SEM review methodology & tools. This paper describe a new approach which enhances process monitoring quality and the results of collaborative work of the Process Diagnostic & Control Business Unit of Applied Materials® and GLOBALFOUNDRIES® utilizing Applied Materials ADRTrueTM & SEMVisionTM capabilities. The study shows that the new approach reveals new defect types in the Pareto, and improves the ability to

  6. Manganese-enhanced magnetic resonance imaging reveals increased DOI-induced brain activity in a mouse model of schizophrenia.

    PubMed

    Malkova, Natalia V; Gallagher, Joseph J; Yu, Collin Z; Jacobs, Russell E; Patterson, Paul H

    2014-06-17

    Maternal infection during pregnancy increases the risk for schizophrenia in offspring. In rodent models, maternal immune activation (MIA) yields offspring with schizophrenia-like behaviors. None of these behaviors are, however, specific to schizophrenia. The presence of hallucinations is a key diagnostic symptom of schizophrenia. In mice, this symptom can be defined as brain activation in the absence of external stimuli, which can be mimicked by administration of hallucinogens. We find that, compared with controls, adult MIA offspring display an increased stereotypical behavioral response to the hallucinogen 2,5-dimethoxy-4-iodoamphetamine (DOI), an agonist for serotonin receptor 2A (5-HT2AR). This may be explained by increased levels of 5-HT2AR and downstream signaling molecules in unstimulated MIA prefrontal cortex (PFC). Using manganese-enhanced magnetic resonance imaging to identify neuronal activation elicited by DOI administration, we find that, compared with controls, MIA offspring exhibit a greater manganese (Mn(2+)) accumulation in several brain areas, including the PFC, thalamus, and striatum. The parafascicular thalamic nucleus, which plays the role in the pathogenesis of hallucinations, is activated by DOI in MIA offspring only. Additionally, compared with controls, MIA offspring demonstrate higher DOI-induced expression of early growth response protein 1, cyclooxygenase-2, and brain-derived neurotrophic factor in the PFC. Chronic treatment with the 5-HT2AR antagonist ketanserin reduces DOI-induced head twitching in MIA offspring. Thus, the MIA mouse model can be successfully used to investigate activity induced by DOI in awake, behaving mice. Moreover, manganese-enhanced magnetic resonance imaging is a useful, noninvasive method for accurately measuring this type of activity. PMID:24889602

  7. Measuring depth of injury (DOI) in an isolated rabbit eye irritation test (IRE) using biomarkers of cell death and viability.

    PubMed

    Jester, James V; Ling, Joseph; Harbell, John

    2010-03-01

    While DOI is a mechanistic correlate to the ocular irritation response, attempts to measure DOI in alternative tests have been limited to qualitative histopathologic assessment by veterinarian pathologists. The purpose of this study was to determine whether DOI could be measured objectively by fluorescent staining for biomarkers of cell death and viability using an ex vivo isolated rabbit eye (IRE) test. A panel of nine materials characterized by in vivo DOI were selected that caused slight (3% acetic acid and 5% SDS), mild (acetone, sodium hypochlorite and 10% acetic acid), moderate (cyclohexanol and parafluoroanaline) and severe (8% sodium hydroxide and 10% benzalkonium chloride) irritation. Materials were then tested using a modified IRE test with 3h recovery and then processed for cyrosectioning and staining using a TUNEL assay to detect cell death, phalloidin to detect intracellular f-actin and DAPI staining to detect nuclei. Control eyes treated with water showed intense phalloidin staining of the corneal epithelium and stromal keratocytes but no TUNEL labeling. In general, eyes treated with mild, moderate and severe irritants showed regions of TUNEL labeled epithelial and keratocyte nuclei with no phalloidin stain overlying phalloidin stained, undamaged cells. DOI measurements showed that slight irritants damaged<40% of the epithelium, mild and moderate irritants damaged>50% of the epithelium, extending at times into the anterior stroma (<20%), and the severe irritant damaged>50% of the stroma. Regression analysis between ex vivo and in vivo DOI showed a significant (p<0.007) correlation (r=0.785). These data suggest that fluorescent staining of fixed and sectioned tissue using biomarkers can be used to objectively identify the depth of injury caused by ocular irritants. PMID:19857567

  8. Manganese-enhanced magnetic resonance imaging reveals increased DOI-induced brain activity in a mouse model of schizophrenia

    PubMed Central

    Malkova, Natalia V.; Gallagher, Joseph J.; Yu, Collin Z.; Jacobs, Russell E.; Patterson, Paul H.

    2014-01-01

    Maternal infection during pregnancy increases the risk for schizophrenia in offspring. In rodent models, maternal immune activation (MIA) yields offspring with schizophrenia-like behaviors. None of these behaviors are, however, specific to schizophrenia. The presence of hallucinations is a key diagnostic symptom of schizophrenia. In mice, this symptom can be defined as brain activation in the absence of external stimuli, which can be mimicked by administration of hallucinogens. We find that, compared with controls, adult MIA offspring display an increased stereotypical behavioral response to the hallucinogen 2,5-dimethoxy-4-iodoamphetamine (DOI), an agonist for serotonin receptor 2A (5-HT2AR). This may be explained by increased levels of 5-HT2AR and downstream signaling molecules in unstimulated MIA prefrontal cortex (PFC). Using manganese-enhanced magnetic resonance imaging to identify neuronal activation elicited by DOI administration, we find that, compared with controls, MIA offspring exhibit a greater manganese (Mn2+) accumulation in several brain areas, including the PFC, thalamus, and striatum. The parafascicular thalamic nucleus, which plays the role in the pathogenesis of hallucinations, is activated by DOI in MIA offspring only. Additionally, compared with controls, MIA offspring demonstrate higher DOI-induced expression of early growth response protein 1, cyclooxygenase-2, and brain-derived neurotrophic factor in the PFC. Chronic treatment with the 5-HT2AR antagonist ketanserin reduces DOI-induced head twitching in MIA offspring. Thus, the MIA mouse model can be successfully used to investigate activity induced by DOI in awake, behaving mice. Moreover, manganese-enhanced magnetic resonance imaging is a useful, noninvasive method for accurately measuring this type of activity. PMID:24889602

  9. Structure and conformational states of the bovine mitochondrial ATP synthase by cryo-EM

    PubMed Central

    Zhou, Anna; Rohou, Alexis; Schep, Daniel G; Bason, John V; Montgomery, Martin G; Walker, John E; Grigorieff, Nikolaus; Rubinstein, John L

    2015-01-01

    Adenosine triphosphate (ATP), the chemical energy currency of biology, is synthesized in eukaryotic cells primarily by the mitochondrial ATP synthase. ATP synthases operate by a rotary catalytic mechanism where proton translocation through the membrane-inserted FO region is coupled to ATP synthesis in the catalytic F1 region via rotation of a central rotor subcomplex. We report here single particle electron cryomicroscopy (cryo-EM) analysis of the bovine mitochondrial ATP synthase. Combining cryo-EM data with bioinformatic analysis allowed us to determine the fold of the a subunit, suggesting a proton translocation path through the FO region that involves both the a and b subunits. 3D classification of images revealed seven distinct states of the enzyme that show different modes of bending and twisting in the intact ATP synthase. Rotational fluctuations of the c8-ring within the FO region support a Brownian ratchet mechanism for proton-translocation-driven rotation in ATP synthases. DOI: http://dx.doi.org/10.7554/eLife.10180.001 PMID:26439008

  10. Beam-induced motion correction for sub-megadalton cryo-EM particles

    PubMed Central

    Scheres, Sjors HW

    2014-01-01

    In electron cryo-microscopy (cryo-EM), the electron beam that is used for imaging also causes the sample to move. This motion blurs the images and limits the resolution attainable by single-particle analysis. In a previous Research article (Bai et al., 2013) we showed that correcting for this motion by processing movies from fast direct-electron detectors allowed structure determination to near-atomic resolution from 35,000 ribosome particles. In this Research advance article, we show that an improved movie processing algorithm is applicable to a much wider range of specimens. The new algorithm estimates straight movement tracks by considering multiple particles that are close to each other in the field of view, and models the fall-off of high-resolution information content by radiation damage in a dose-dependent manner. Application of the new algorithm to four data sets illustrates its potential for significantly improving cryo-EM structures, even for particles that are smaller than 200 kDa. DOI: http://dx.doi.org/10.7554/eLife.03665.001 PMID:25122622

  11. STS-87 Mission Specialists Scott and Doi with EVA coordinator Laws participate in the CEIT for their

    NASA Technical Reports Server (NTRS)

    1997-01-01

    Participating in the Crew Equipment Integration Test (CEIT) at Kennedy Space Center are STS-87 crew members, assisted by Glenda Laws, extravehicular activity (EVA) coordinator, Johnson Space Center, at left. Next to Laws is Mission Specialist Takao Doi, Ph.D., of the National Space Development Agency of Japan, who is looking on as Mission Specialist Winston Scott gets a hands-on look at some of the equipment. The STS-87 mission will be the fourth United States Microgravity Payload and flight of the Spartan-201 deployable satellite. During the mission, scheduled for a Nov. 19 liftoff from KSC, Dr. Doi and Scott will both perform spacewalks.

  12. Observações simultâneas no óptico e infravermelho próximo dos BL Lacs PKS 2005-489 e PKS 2155-304 em diversas escalas de tempo

    NASA Astrophysics Data System (ADS)

    Dominici, T. P.; Abraham, Z.; Galo, A. L.

    2003-08-01

    A existência de variações rápidas de brilho em alguns blazares é um fenômeno bem comprovado, mas até agora não sabemos ao certo quais são os mecanismos físicos envolvidos. A maior dificuldade é a ausência de observações multibanda simultâneas que poderiam fornecer vínculos aos modelos. Buscando colaborar com a discussão estudamos o comportamento de dois BL Lacs, PKS 2005-489 e PKS 2155-304, em relação à variabilidade em diversas escalas de tempo, de poucos minutos até vários meses, com observações simultâneas em seis bandas espectrais (óptico e infravermelho próximo). Para tanto dois telescópios do LNA foram utilizados em conjunto nas campanhas observacionais realizadas em 2001 e 2002, cujos resultados são apresentados aqui. As duas fontes apresentaram características bastante diferentes, inclusive em relação à existência de variabilidade nos índices espectrais. Particularmente, registramos a primeira detecção de variações em escalas de tempo da ordem de poucos minutos em PKS 2005-489, com evidências da presença de um atraso entre as curvas de luz nas bandas V e R e a variação em R ocorrendo antes (o contrário do esperado no modelo de shock-in-jet). Em PKS 2155-304 detectamos pela primeira vez variabilidade em escalas de tempo de poucos minutos no infravermelho em um AGN. As observações indicam que as variações de brilho em blazares são o resultado da ação de mais de um fenômeno, especialmente em escalas de tempo muito curtas. Alguns cenários físicos são sugeridos para explicar os resultados observacionais.

  13. Identified EM Earthquake Precursors

    NASA Astrophysics Data System (ADS)

    Jones, Kenneth, II; Saxton, Patrick

    2014-05-01

    Many attempts have been made to determine a sound forecasting method regarding earthquakes and warn the public in turn. Presently, the animal kingdom leads the precursor list alluding to a transmission related source. By applying the animal-based model to an electromagnetic (EM) wave model, various hypotheses were formed, but the most interesting one required the use of a magnetometer with a differing design and geometry. To date, numerous, high-end magnetometers have been in use in close proximity to fault zones for potential earthquake forecasting; however, something is still amiss. The problem still resides with what exactly is forecastable and the investigating direction of EM. After a number of custom rock experiments, two hypotheses were formed which could answer the EM wave model. The first hypothesis concerned a sufficient and continuous electron movement either by surface or penetrative flow, and the second regarded a novel approach to radio transmission. Electron flow along fracture surfaces was determined to be inadequate in creating strong EM fields, because rock has a very high electrical resistance making it a high quality insulator. Penetrative flow could not be corroborated as well, because it was discovered that rock was absorbing and confining electrons to a very thin skin depth. Radio wave transmission and detection worked with every single test administered. This hypothesis was reviewed for propagating, long-wave generation with sufficient amplitude, and the capability of penetrating solid rock. Additionally, fracture spaces, either air or ion-filled, can facilitate this concept from great depths and allow for surficial detection. A few propagating precursor signals have been detected in the field occurring with associated phases using custom-built loop antennae. Field testing was conducted in Southern California from 2006-2011, and outside the NE Texas town of Timpson in February, 2013. The antennae have mobility and observations were noted for

  14. The Past, Present and Future of the Compact Disc, Multimedia and the Industry: An Interview with Sony's Dr. Toshi Doi.

    ERIC Educational Resources Information Center

    Herther, Nancy

    1992-01-01

    This interview with Dr. Toshi Doi, director of the Sony Corporation, covers his work at Sony, the multimedia industry, industry cooperation, Sony compact disc products and formats, multimedia standards and pricing, multimedia formats, and the future of the industry. A diagram of computer companies and corresponding multimedia platforms is…

  15. 25 CFR 900.208 - How are non-medical related tort claims and lawsuits filed for DOI?

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 25 Indians 2 2011-04-01 2011-04-01 false How are non-medical related tort claims and lawsuits...-DETERMINATION AND EDUCATION ASSISTANCE ACT Federal Tort Claims Act Coverage General Provisions Non-Medical Related Claims § 900.208 How are non-medical related tort claims and lawsuits filed for DOI?...

  16. Exploring Learner Perception of E-Learning Effectiveness in the Workplace Learning Context Based on Diffusion of Innovations (DOI) Model

    ERIC Educational Resources Information Center

    Chen, Tzu-Ling; Chen, Tzu-Jung

    2006-01-01

    The purpose of this study aims to examine adult learner's perception related to e-learning effectiveness. The model of diffusion of innovations (DOI) was used as the research framework and quantitative research methodology employing survey techniques was applied to collect the data. The targeted population identified in this study includes adult…

  17. DOIs for Data: Progress in Data Citation and Publication in the Geosciences

    NASA Astrophysics Data System (ADS)

    Callaghan, S.; Murphy, F.; Tedds, J.; Allan, R.

    2012-12-01

    publication, and assessing the trustworthiness of data archives. A key goal is to ensure that these projects reach out to, and are informed by, other related initiatives on a global basis, in particular anyone interested in developing long-term sustainable policies, processes, incentives and business models for managing and publishing research data. This presentation will give an overview of progress in the projects mentioned above, specifically focussing on the use of DOIs for datasets hosted in the NERC environmental data centers, and how DOIs are enabling formal data citation and publication in the geosciences.

  18. STS-87 M.S. Takao Doi, Ph.D., of NASDA after landing

    NASA Technical Reports Server (NTRS)

    1997-01-01

    STS-87 Mission Specialist Takao Doi, Ph.D., of the National Space Development Agency (NASDA) of Japan greets a NASDA official shortly after the orbiter Columbia returned to KSC, touching down on Runway 33 at KSC's Shuttle Landing Facility. STS-87 concluded its mission with a main gear touchdown at 7:20:04 a.m. EST Dec. 5, drawing the 15-day, 16-hour and 34-minute-long mission of 6.5 million miles to a close. Also onboard the orbiter were Commander Kevin Kregel; Pilot Steven Lindsey; Mission Specialists Winston Scott and Kalpana Chawla, Ph.D.; and Payload Specialist Leonid Kadenyuk of the National Space Agency of Ukraine. During the 88th Space Shuttle mission, the crew performed experiments on the United States Microgravity Payload-4 and pollinated plants as part of the Collaborative Ukrainian Experiment. This was the 12th landing for Columbia at KSC and the 41st KSC landing in the history of the Space Shuttle program.

  19. NASDA President Isao Uchida greets STS-87 Mission Specialist Takao Doi, Ph.D., after landing

    NASA Technical Reports Server (NTRS)

    1997-01-01

    The president of the National Space Development Agency (NASDA) of Japan, Isao Uchida, at left, chats with STS-87 Mission Specialist Takao Doi, Ph.D., of NASDA, shortly after the landing of Columbia at Kennedy Space Center. STS-87 concluded its mission with a main gear touchdown at 7:20:04 a.m. EST Dec. 5, at KSC's Shuttle Landing Facility Runway 33, drawing the 15-day, 16-hour and 34- minute-long mission of 6.5 million miles to a close. Also onboard the orbiter were Commander Kevin Kregel; Pilot Steven Lindsey; Mission Specialists Winston Scott and Kalpana Chawla, Ph.D.; and Payload Specialist Leonid Kadenyuk of the National Space Agency of Ukraine. During the 88th Space Shuttle mission, the crew performed experiments on the United States Microgravity Payload-4 and pollinated plants as part of the Collaborative Ukrainian Experiment. This was the 12th landing for Columbia at KSC and the 41st KSC landing in the history of the Space Shuttle program.

  20. 25 CFR 1000.55 - Can a Tribe/Consortium appeal within DOI the Director's decision not to award a grant under this...

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 25 Indians 2 2010-04-01 2010-04-01 false Can a Tribe/Consortium appeal within DOI the Director's decision not to award a grant under this subpart? 1000.55 Section 1000.55 Indians OFFICE OF THE ASSISTANT... Negotiation Grants Advance Planning Grant Funding § 1000.55 Can a Tribe/Consortium appeal within DOI...

  1. EPA LABORATORIES IMPLEMENT EMS PROGRAM

    EPA Science Inventory

    This paper highlights the breadth and magnitude of carrying out an effective Environmental Management System (EMS) program at the U.S. EPA's research and development laboratories. Federal research laboratories have unique operating challenges compared to more centralized industr...

  2. Concept for Future Data Services at the Long-Term Archive of WDCC combining DOIs with common PIDs

    NASA Astrophysics Data System (ADS)

    Stockhause, Martina; Weigel, Tobias; Toussaint, Frank; Höck, Heinke; Thiemann, Hannes; Lautenschlager, Michael

    2013-04-01

    The World Data Center for Climate (WDCC) hosted at the German Climate Computing Center (DKRZ) maintains a long-term archive (LTA) of climate model data as well as observational data. WDCC distinguishes between two types of LTA data: Structured data: Data output of an instrument or of a climate model run consists of numerous, highly structured individual datasets in a uniform format. Part of these data is also published on an ESGF (Earth System Grid Federation) data node. Detailed metadata is available allowing for fine-grained user-defined data access. Unstructured data: LTA data of finished scientific projects are in general unstructured and consist of datasets of different formats, different sizes, and different contents. For these data compact metadata is available as content information. The structured data is suitable for WDCC's DataCite DOI process, the project data only in exceptional cases. The DOI process includes a thorough quality control process of technical as well as scientific aspects by the publication agent and the data creator. DOIs are assigned to data collections appropriate to be cited in scientific publications, like a simulation run. The data collection is defined in agreement with the data creator. At the moment there is no possibility to identify and cite individual datasets within this DOI data collection analogous to the citation of chapters in a book. Also missing is a compact citation regulation for a user-specified collection of data. WDCC therefore complements its existing LTA/DOI concept by Persistent Identifier (PID) assignment to datasets using Handles. In addition to data identification for internal and external use, the concept of PIDs allows to define relations among PIDs. Such structural information is stored as key-value pair directly in the handles. Thus, relations provide basic provenance or lineage information, even if part of the data like intermediate results are lost. WDCC intends to use additional PIDs on metadata

  3. A new forest-dwelling Bent-toed Gecko (Squamata: Gekkonidae: Cyrtodactylus) from Doi Inthanon, Chiang Mai Province, northern Thailand.

    PubMed

    Kunya, Kirati; Sumontha, Montri; Panitvong, Nonn; Dongkumfu, Wuttipong; Sirisamphan, Thana; Pauwels, Olivier S G

    2015-01-01

    We describe a new forest-dwelling Cyrtodactylus from Doi Inthanon, Chiang Mai Province, northern Thailand. Cyrtodactylus inthanon sp. nov. is characterized by a maximum known SVL of 87.3 mm; 18 to 20 longitudinal rows of dorsal tubercles; a continuous series of 34 to 37 enlarged femoro-precloacal scales, including four to six pitted (female) or pore-bearing (male) scales on each femur separated by a diastema from five pitted (females) or pore-bearing (male) precloacal scales; no precloacal groove or depression; transversely enlarged subcaudal scales; and three to five irregular beige dorsal bands between limb insertions. The discovery of a new reptile endemic to Doi Inthanon reinforces the high importance of this mountain in terms of biodiversity conservation. PMID:25661232

  4. Characterization of a high-resolution hybrid DOI detector for a dedicated breast PET/CT scanner.

    PubMed

    Godinez, Felipe; Chaudhari, Abhijit J; Yang, Yongfeng; Farrell, Richard; Badawi, Ramsey D

    2012-06-01

    The aim of this study is to design and test a new high-resolution hybrid depth of interaction (DOI) detector for a dedicated breast PET/CT scanner. Two detectors have been designed and built. The completed detectors are based on a 14 × 14 array of 1.5 × 1.5 × 20 mm(3) unpolished lutetium orthosilicate scintillation crystals, with each element coated in a 50 μm layer of reflective material. The detector is read out from both ends using a position-sensitive photomultiplier tube (PSPMT) and a large active area (20 × 20 mm(2)) avalanche photodiode (APD) to enable acquisition of DOI information. Nuclear instrumentation modules were used to characterize the detectors' performances in terms of timing, intrinsic spatial resolution (ISR) and energy resolution, as well as DOI resolution with a dual-ended readout configuration. Measurements with the APD were performed at a temperature of 10 °C. All crystals were identified at all depths, even though the signal amplitude from the PSPMT decreases with depth away from it. We measured a timing resolution of 2.4 ns, and an average energy resolution of 19%. The mean ISR was measured to be 1.2 mm for crystals in the central row of the array for detectors in the face-to-face position. Two off-center positions were measured corresponding to 26° and 51° oblique photon incidence, and the mean ISR at these positions was 1.5 and 1.7 mm, respectively. The average DOI resolution across all crystals and depths was measured to be 2.9 mm (including the beam width of 0.6 mm). This detector design shows good promise as a high-resolution detector for a dedicated breast PET/CT scanner. PMID:22581109

  5. 77 FR 19307 - Renewal of Information Collection; OMB Control Number 1040-0001, DOI Programmatic Clearance for...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-03-30

    ...We (Department of the Interior, DOI) have submitted a request to the Office of Management and Budget (OMB) to approve the information collection (IC) described below. This IC is scheduled to expire March 31, 2012. As required by the Paperwork Reduction Act of 1995 and as part of our continuing efforts to reduce paperwork and respondent burden, we invite the general public and other Federal......

  6. Ondas de choque em jatos de quasares e objetos BL Lacertae

    NASA Astrophysics Data System (ADS)

    Melo, F. E.; Botti, L. C. L.

    2003-08-01

    Este trabalho é parte de um projeto que vem sendo realizado há dois anos no CRAAM, cujos objetivos principais são analisar e aplicar um modelo generalizado de ondas de choque em jatos relativísticos de plasma, presentes em quasares e objetos BL Lacertae, para explicar a variabilidade observada nestes objetos. O método consiste em uma decomposição de curvas de luz em séries de explosões similares, em várias freqüências, baseando-se em uma evolução espectro-temporal média das explosões. A partir da evolução média, um ajuste de cada explosão é feito com base em equações empíricas, modificando-se apenas parâmetros específicos de cada explosão. Inicialmente o modelo foi aplicado ajustando-se as curvas de luz a explosões delineadas por uma evolução do choque em três estágios, segundo a predominância do processo de emissão: síncrotron, Compton e adiabático. Entretanto, nesta nova fase de projeto, visando uma parametrização mais concisa, uma otimização do algoritmo de ajuste e uma convergência mais rápida, a formulação para cada evento foi assumida com uma evolução em apenas dois estágios: subida e descida. Isto possibilitou uma ótima delineação das curvas de luz das fontes OV236, OJ287, 3C273 e BL Lac, entre 1980 e 2000, nas freqüências 4.8, 8.0, 14.5 e 22 GHz, utilizando-se dados do Observatório da Universidade de Michigan, do Observatório do Itapetinga (Atibaia SP) e do Observatório Metsähovi. Como conclusões importantes, verificou-se que: os parâmetros ajustados descrevem o comportamento do jato; os valores do índice que descreve a expansão do jato sugerem que o mesmo se expande de uma forma não-cônica; o campo magnético é turbulento atrás da frente de choque; e as peculiaridades das explosões são devidas à influência de grandezas tais como o coeficiente da distribuição espectral de energia dos elétrons, a intensidade de campo magnético e o fator de feixe Doppler, no início do choque.

  7. Is EMS communicating with the FCC?

    PubMed

    Johnson, M S; VanCott, C; Glass, C; Anderson, P B

    1989-07-01

    Radio communication problems in EMS run the spectrum from annoying to deadly. Dedicated radio frequencies for EMS, much like those exclusive to police and fire departments, are long overdue. PMID:10293680

  8. Side readout of long scintillation crystal elements with digital SiPM for TOF-DOI PET

    SciTech Connect

    Yeom, Jung Yeol E-mail: cslevin@stanford.edu; Vinke, Ruud; Levin, Craig S. E-mail: cslevin@stanford.edu

    2014-12-15

    Purpose: Side readout of scintillation light from crystal elements in positron emission tomography (PET) is an alternative to conventional end-readout configurations, with the benefit of being able to provide accurate depth-of-interaction (DOI) information and good energy resolution while achieving excellent timing resolution required for time-of-flight PET. This paper explores different readout geometries of scintillation crystal elements with the goal of achieving a detector that simultaneously achieves excellent timing resolution, energy resolution, spatial resolution, and photon sensitivity. Methods: The performance of discrete LYSO scintillation elements of different lengths read out from the end/side with digital silicon photomultipliers (dSiPMs) has been assessed. Results: Compared to 3 × 3 × 20 mm{sup 3} LYSO crystals read out from their ends with a coincidence resolving time (CRT) of 162 ± 6 ps FWHM and saturated energy spectra, a side-readout configuration achieved an excellent CRT of 144 ± 2 ps FWHM after correcting for timing skews within the dSiPM and an energy resolution of 11.8% ± 0.2% without requiring energy saturation correction. Using a maximum likelihood estimation method on individual dSiPM pixel response that corresponds to different 511 keV photon interaction positions, the DOI resolution of this 3 × 3 × 20 mm{sup 3} crystal side-readout configuration was computed to be 0.8 mm FWHM with negligible artifacts at the crystal ends. On the other hand, with smaller 3 × 3 × 5 mm{sup 3} LYSO crystals that can also be tiled/stacked to provide DOI information, a timing resolution of 134 ± 6 ps was attained but produced highly saturated energy spectra. Conclusions: The energy, timing, and DOI resolution information extracted from the side of long scintillation crystal elements coupled to dSiPM have been acquired for the first time. The authors conclude in this proof of concept study that such detector configuration has the potential to enable

  9. Astronomia para/com crianças carentes em Limeira

    NASA Astrophysics Data System (ADS)

    Bretones, P. S.; Oliveira, V. C.

    2003-08-01

    Em 2001, o Instituto Superior de Ciências Aplicadas (ISCA Faculdades de Limeira) iniciou um projeto pelo qual o Observatório do Morro Azul empreendeu uma parceria com o Centro de Promoção Social Municipal (CEPROSOM), instituição mantida pela Prefeitura Municipal de Limeira para atender crianças e adolescentes carentes. O CEPROSOM contava com dois projetos: Projeto Centro de Convivência Infantil (CCI) e Programa Criança e Adolescente (PCA), que atendiam crianças e adolescentes em Centros Comunitários de diversas áreas da cidade. Esses projetos têm como prioridades estabelecer atividades prazerosas para as crianças no sentido de retirá-las das ruas. Assim sendo, as crianças passaram a ter mais um tipo de atividade - as visitas ao observatório. Este painel descreve as várias fases do projeto, que envolveu: reuniões de planejamento, curso de Astronomia para as orientadoras dos CCIs e PCAs, atividades relacionadas a visitas das crianças ao Observatório, proposta de construção de gnômons e relógios de Sol nos diversos Centros Comunitários de Limeira e divulgação do projeto na imprensa. O painel inclui discussões sobre a aprendizagem de crianças carentes, relatos que mostram a postura das orientadoras sobre a pertinência do ensino de Astronomia, relatos do monitor que fez o atendimento no Observatório e o que o número de crianças atendidas representou para as atividades da instituição desde o início de suas atividades e, em particular, em 2001. Os resultados são baseados na análise de relatos das orientadoras e do monitor do Observatório, registros de visitas e matérias da imprensa local. Conclui com uma avaliação do que tal projeto representou para as Instituições participantes. Para o Observatório, em particular, foi feita uma análise com relação às outras modalidades de atendimentos que envolvem alunos de escolas e público em geral. Também é abordada a questão do compromisso social do Observatório na educação do

  10. Alveolar Echinococcosis: Characterization of Diagnostic Antigen Em18 and Serological Evaluation of Recombinant Em18

    PubMed Central

    Sako, Yasuhito; Nakao, Minoru; Nakaya, Kazuhiro; Yamasaki, Hiroshi; Gottstein, Bruno; Lightowers, Marshall W.; Schantz, Peter M.; Ito, Akira

    2002-01-01

    The Echinococcus multilocularis protein Em18 is one of the most promising antigens for use in serodiagnosis of alveolar echinococcosis in human patients. Here we identify an antigenic relationship between Em18 and a 65-kDa immunodominant E. multilocularis surface protein previously identified as either EM10 or EmII/3. The NH2-terminal sequence of native Em18 was determined, revealing it to be a fragment of EM10. Experiments were undertaken to investigate the effect of proteinase inhibitors on the degradation of EM10 in crude extracts of E. multilocularis protoscoleces. Em18 was found to be the product of degradation of EM10 by cysteine proteinase. A recombinant Em18 (RecEm18, derived from 349K to 508K of EM10) was successfully expressed by using Escherichia coli expression system and then evaluated for use in serodiagnosis of alveolar echinococcosis. RecEm18 was recognized by 27 (87.1%) and 28 (90.3%) of 31 serum samples from clinically and/or pathologically confirmed alveolar echinococcosis patients by enzyme-linked immunosorbent assay and immunoblotting, respectively. Of 33 serum samples from cystic echinococcosis patients, 1 was recorded as having a weak positive reaction to RecEm18; however, none of the serum samples which were tested from neurocysticercosis patients (n = 10) or healthy people (n = 15) showed positive reactions. RecEm18 has the potential for use in the differential serodiagnosis of alveolar echinococcosis. PMID:12149326

  11. The European Mobile System (EMS)

    NASA Technical Reports Server (NTRS)

    Jongejans, A.; Rogard, R.; Mistretta, I.; Ananasso, F.

    1993-01-01

    The European Space Agency is presently procuring an L band payload in order to promote a regional European L band system coping with the specific needs of the European market. The payload, and the two communications systems to be supported, are described below. The potential market for EMS in Europe is discussed.

  12. Detecção inesperada de efeitos de lentes fracas em grupos de galáxias pouco luminosos em raios-X

    NASA Astrophysics Data System (ADS)

    Carrasco, R.; Mendes de Oliveira, C.; Sodrã©, L., Jr.; Lima Neto, G. B.; Cypriano, E. S.; Lengruber, L. L.; Cuevas, H.; Ramirez, A.

    2003-08-01

    Obtivemos, como parte do programa de verificação científica do GMOS Sul, imagens profundas de três grupos de galáxias: G97 e G102 (z~0,4) e G124 (z = 0,17). Esses alvos foram selecionados a partir do catálogo de fontes extensas de Vikhlinin (1998), por terem luminosidades em raios X menores que 3´1043 ergs s-1, valor cerca de uma ou duas ordens de grandeza inferior ao de aglomerados de galáxias. O objetivo primário dessas observações é o estudo da evolução de galáxias em grupos. Grupos são ambientes menos densos que aglomerados, contêm a grande maioria das galáxias do Universo mas que, até o momento, foram estudados detalhadamente apenas no Universo local (z~0). Com esses dados efetuamos uma análise estatística da distorção na forma das galáxias de fundo (lentes gravitacionais fracas) como forma de inferir o conteúdo e a distribuição de massa nesses grupos apesar de que, em princípio, esse efeito não deveria ser detectado uma vez que os critérios de seleção adotados previlegiam sistemas de baixa massa. De fato, para G124 obtivemos apenas um limite superior para sua massa que é compatível com sua luminosidade em raios X. De modo contrário e surpreendente, os objetos G102 e G097, aparentam ter massas que resultariam em dispersões de velocidade maiores que 1000 km s-1, muito maiores do que se espera para grupos de galáxias. Com efeito, para G097 obtivemos, a partir de dados do satélite XMM, uma estimativa para a temperatura do gás intragrupo de kT = 2,6 keV, que é tipica de sistemas com dispersões de velocidade de ~ 600 km s-1, bem característica de grupos. Essas contradições aparentes entre lentes fracas e raios X podem ser explicadas de dois modos: i) a massa obtida por lentes estaria sobreestimada devido à superposição de estruturas massivas ao longo da linha de visada ou ii) a temperatura do gás do meio intra-grupo reflete o potencial gravitacional de estruturas menores que estariam se fundindo para formar uma

  13. Basic performance evaluation of a Si-PM array-based LGSO phoswich DOI block detector for a high-resolution small animal PET system.

    PubMed

    Yamamoto, Seiichi

    2013-07-01

    The silicon photomultiplier (Si-PM) is a promising photodetector for PET. However, it remains unclear whether Si-PM can be used for a depth-of-interaction (DOI) detector based on the decay time differences of the scintillator where pulse shape analysis is used. For clarification, we tested the Hamamatsu 4 × 4 Si-PM array (S11065-025P) combined with scintillators that used different decay times to develop DOI block detectors using the pulse shape analysis. First, Ce-doped Gd(2)SiO(5) (GSO) scintillators of 0.5 mol% Ce were arranged in a 4 × 4 matrix and were optically coupled to the center of each pixel of the Si-PM array for measurement of the energy resolution as well as its gain variations according to the temperature. Then two types of Ce-doped Lu(1.9)Gd(0.1)Si0(5) (LGSO) scintillators, 0.025 mol% Ce (decay time: ~31 ns) and 0.75 mol% Ce (decay time: ~46 ns), were optically coupled in the DOI direction, arranged in a 11 × 7 matrix, and optically coupled to a Si-PM array for testing of the possibility of a high-resolution DOI detector. The energy resolution of the Si-PM array-based GSO block detector was 18 ± 4.4 % FWHM for a Cs-137 gamma source (662 keV). Less than 1 mm crystals were clearly resolved in the position map of the LGSO DOI block detector. The peak-to-valley ratio (P/V) derived from the pulse shape spectra of the LGSO DOI block detector was 2.2. These results confirmed that Si-PM array-based DOI block detectors are promising for high-resolution small animal PET systems. PMID:23271446

  14. The effect of the sigma-1 receptor selective compound LS-1-137 on the DOI-induced head twitch response in mice.

    PubMed

    Malik, Maninder; Rangel-Barajas, Claudia; Mach, Robert H; Luedtke, Robert R

    2016-09-01

    Several receptor mediated pathways have been shown to modulate the murine head twitch response (HTR). However, the role of sigma receptors in the murine (±)-2,5-dimethoxy-4-iodoamphetamine (DOI)-induced HTR has not been previously investigated. We examined the ability of LS-1-137, a novel sigma-1 vs. sigma-2 receptor selective phenylacetamide, to modulate the DOI-induced HTR in DBA/2J mice. We also assessed the in vivo efficacy of reference sigma-1 receptor antagonists and agonists PRE-084 and PPCC. The effect of the sigma-2 receptor selective antagonist RHM-1-86 was also examined. Rotarod analysis was performed to monitor motor coordination after LS-1-137 administration. Radioligand binding techniques were used to determine the affinity of LS-1-137 at 5-HT2A and 5-HT2C receptors. LS-1-137 and the sigma-1 receptor antagonists haloperidol and BD 1047 were able to attenuate a DOI-induced HTR, indicating that LS-1-137 was acting in vivo as a sigma-1 receptor antagonist. LS-1-137 did not compromise rotarod performance within a dose range capable of attenuating the effects of DOI. Radioligand binding studies indicate that LS-1-137 exhibits low affinity binding at both 5-HT2A and 5-HT2C receptors. Based upon the results from these and our previous studies, LS-1-137 is a neuroprotective agent that attenuates the murine DOI-induced HTR independent of activity at 5-HT2 receptor subtypes, D2-like dopamine receptors, sigma-2 receptors and NMDA receptors. LS-1-137 appears to act as a sigma-1 receptor antagonist to inhibit the DOI-induced HTR. Therefore, the DOI-induced HTR can be used to assess the in vivo efficacy of sigma-1 receptor selective compounds. PMID:27397487

  15. Exploring facilitating factors and barriers to the nationwide dissemination of a Dutch school-based obesity prevention program “DOiT”: a study protocol

    PubMed Central

    2013-01-01

    Background The evidence-based Dutch Obesity Intervention in Teenagers (DOiT) program is a school-based obesity prevention program for 12 to 14-year olds attending the first two years of prevocational education. This paper describes the study protocol applied to evaluate (a) the nationwide dissemination process of DOiT in the Netherlands, and (b) the relationship between quality of implementation and effectiveness during nationwide dissemination of the program in the Netherlands. Methods In order to explore facilitating factors and barriers for dissemination of DOiT, we monitored the process of adoption, implementation and continuation of the DOiT program among 20 prevocational schools in the Netherlands. The study was an observational study using qualitative (i.e. semi-structured interviews) and quantitative methods (i.e. questionnaires and logbooks). Eight process indicators were assessed: recruitment, context, reach, dosage, fidelity, satisfaction, effectiveness and continuation. All teachers, students and parents involved in the implementation of the program were invited to participate in the study. As part of the process evaluation, a cluster-controlled trial with ten control schools was conducted to evaluate the effectiveness of the program on students’ anthropometry and energy balance-related behaviours and its association with quality of implementation. Discussion The identified impeding and facilitating factors will contribute to an adjusted strategy promoting adoption, implementation and continuation of the DOiT program to ensure optimal use and, thereby, prevention of obesity in Dutch adolescents. Trial registration Current Controlled Trials ISRCTN92755979. PMID:24355056

  16. Biaxial deformation of a polymer under shear: NMR test of the Doi-Edwards model with convected constraint release

    NASA Astrophysics Data System (ADS)

    Cormier, Ryan J.; Kilfoil, Maria L.; Callaghan, Paul T.

    2001-11-01

    2H NMR quadrupole interaction spectroscopy has been used to measure the deformation of a 670 kD poly(dimethylsiloxane) melt under shear in a Couette cell. The signals were acquired from a per deuterated benzene probe molecule which provides a motionally averaged sampling of the entire segmental ensemble. We have measured the dependence on shear rate of the SXX (velocity), SYY (velocity gradient), SZZ (vorticity), and SXY (shear) elements of the segmental alignment tensor, as well as the angular dependence of the deuterium quadrupole splitting at fixed shear rate. We show that the data agree quite well with the Doi-Edwards theory but significantly better when convected constraint release effects are included. These fits return a value for the tube disengagement time of 100 ms.

  17. Hyperspectral Technology Transfer to the US Department of Interior: Summary of Results of the NASA/DOI Hyperspectral Technology Transfer Project

    NASA Technical Reports Server (NTRS)

    Root, Ralph; Wickland, Diane

    2001-01-01

    In 1997 the Office of Biological Informatics and Outreach (OBIO), Biological Resources Division, US Geological Survey and NASA, Office of Earth Science (OES), initiated a coordinated effort for applying Airborne Visible and Infrared Imaging Spectrometer (AVIRIS) data and analysis, as a technology transfer project, to critical DOI environmental issues in four study sites throughout the United States. This work was accomplished by four US Department of the Interior (DOI) study teams with support from NASA/OES principal investigators and the Office of Earth Science programs. The studies, including personnel, objectives, background, project plans, and milestones were documented in a project website at . This report summarizes the final outcomes of the project, detailing accomplishments, lessons learned, and benefits realized to NASA, the US Geological Survey, and the participating DOI bureaus.

  18. DOE/EM Criticality Safety Needs Assessment

    SciTech Connect

    Westfall, Robert Michael; Hopper, Calvin Mitchell

    2011-02-01

    The issue of nuclear criticality safety (NCS) in Department of Energy Environmental Management (DOE/EM) fissionable material operations presents challenges because of the large quantities of material present in the facilities and equipment that are committed to storage and/or material conditioning and dispositioning processes. Given the uncertainty associated with the material and conditions for many DOE/EM fissionable material operations, ensuring safety while maintaining operational efficiency requires the application of the most-effective criticality safety practices. In turn, more-efficient implementation of these practices can be achieved if the best NCS technologies are utilized. In 2002, DOE/EM-1 commissioned a survey of criticality safety technical needs at the major EM sites. These needs were documented in the report Analysis of Nuclear Criticality Safety Technology Supporting the Environmental Management Program, issued May 2002. Subsequent to this study, EM safety management personnel made a commitment to applying the best and latest criticality safety technology, as described by the DOE Nuclear Criticality Safety Program (NCSP). Over the past 7 years, this commitment has enabled the transfer of several new technologies to EM operations. In 2008, it was decided to broaden the basis of the EM NCS needs assessment to include not only current needs for technologies but also NCS operational areas with potential for improvements in controls, analysis, and regulations. A series of NCS workshops has been conducted over the past years, and needs have been identified and addressed by EM staff and contractor personnel. These workshops were organized and conducted by the EM Criticality Safety Program Manager with administrative and technical support by staff at Oak Ridge National Laboratory (ORNL). This report records the progress made in identifying the needs, determining the approaches for addressing these needs, and assimilating new NCS technologies into EM

  19. Measuring the optimal exposure for single particle cryo-EM using a 2.6 Å reconstruction of rotavirus VP6

    PubMed Central

    Grant, Timothy; Grigorieff, Nikolaus

    2015-01-01

    Biological specimens suffer radiation damage when imaged in an electron microscope, ultimately limiting the attainable resolution. At a given resolution, an optimal exposure can be defined that maximizes the signal-to-noise ratio in the image. Using a 2.6 Å resolution single particle cryo-EM reconstruction of rotavirus VP6, determined from movies recorded with a total exposure of 100 electrons/Å2, we obtained accurate measurements of optimal exposure values over a wide range of resolutions. At low and intermediate resolutions, our measured values are considerably higher than obtained previously for crystalline specimens, indicating that both images and movies should be collected with higher exposures than are generally used. We demonstrate a method of using our optimal exposure values to filter movie frames, yielding images with improved contrast that lead to higher resolution reconstructions. This ‘high-exposure’ technique should benefit cryo-EM work on all types of samples, especially those of relatively low-molecular mass. DOI: http://dx.doi.org/10.7554/eLife.06980.001 PMID:26023829

  20. School Budget Hold'em Facilitator's Guide

    ERIC Educational Resources Information Center

    Education Resource Strategies, 2012

    2012-01-01

    "School Budget Hold'em" is a game designed to help school districts rethink their budgeting process. It evolved out of Education Resource Strategies' (ERS) experience working with large urban districts around the country. "School Budget Hold'em" offers a completely new approach--one that can turn the budgeting process into a long-term visioning…

  1. View of Spacelab engineering Model (EM)

    NASA Technical Reports Server (NTRS)

    1981-01-01

    View of Spacelab engineering Model (EM) as it is being brought in the O and C bldg at Kenndey Space Center (27464); view of the EM as it is being offloaded from the C-54 aircraft. Kennedy Space Center alternative photo number is 108-KSC-80-OC-666 (27465); model taken out to launch pad (27466).

  2. EM international activities. February 1997 highlights

    SciTech Connect

    1997-02-01

    EM International Highlights is a brief summary of on-going international projects within the Department of Energy`s Office of Environmental Management (EM). This document contains sections on: Global Issues, activities in Western Europe, activities in central and Eastern Europe, activities in Russia, activities in Asia and the Pacific Rim, activities in South America, activities in North America, and International Organizations.

  3. Memória fonológica em crianças bilíngues bimodais e crianças com implante coclear

    PubMed Central

    de Quadros, Ronice Müller; Cruz, Carina Rebello; Pizzio, Aline Lemos

    2014-01-01

    RESUMO Este estudo comparou o desempenho de crianças bilíngues bimodais ouvintes (filhas de pais surdos) e crianças surdas usuárias de implante coclear (filhas de pais surdos e de pais ouvintes), com diferentes contextos de acesso à Língua Brasileira de Sinais (Libras), em tarefas que envolvem memória fonologica. Os testes utilizados foram: Teste de Pseudopalavras (Santos e Bueno, 2003) e Teste de Pseudosinais (desenvolvido pelos pesquisadores responsáveis pelo Projeto ‘Desenvolvimento Bilíngue Bimoda’). Além disso, foram incluídos dois grupos de controle, formados por crianças surdas (usuarias de Libras), e adultos bilíngues bimodais ouvintes. Na análise dos resultados, em relação ao desempenho entre os dois grupos testados foi constatado que o grupo de crianças bilíngues bimodais ouvintes apresentou desempenho superior, nos dois testes. No entanto, ao ser analisado o desempenho da criança surda usuaria de implante coclear, filha de pais surdos, que possui acesso irrestrito à Libras e comparado com o das crianças surdas usuárias de implante coclear, que possuem acesso restrito à Libras, foi constatado que o seu desempenho foi semelhante ao do grupo de crianças bilíngues bimodais ouvintes. As crianças surdas usuárias de implante coclear com acesso restrito à Libras e, portanto, com acesso maior ao Português apresentaram escores mais baixos nas tarefas, principalmente do teste em Português. Os resultados sugerem que as crianças surdas usuárias de implante coclear em processo de aquisição da línguagem podem se beneficiar com o acesso irrestrito à Libras, atingindo inclusive desempenho semelhante a de crianças bilíngues bimodais ouvintes. PMID:25110473

  4. A Common Model To Support Interoperable Metadata: Progress Report on Reconciling Metadata Requirements from the Dublin Core and INDECS/DOI Communities.

    ERIC Educational Resources Information Center

    Bearman, David; Rust, Godfrey; Weibel, Stuart; Miller, Eric; Trant, Jennifer

    1999-01-01

    The Dublin Core metadata community and the INDECS/DOI community of authors, rights holders, and publishers are seeking common ground in the expression of metadata for information resources. An open "Schema Harmonization" working group has been established to identify a common framework to support interoperability among these communities.…

  5. Negative decision outcomes are more common among people with lower decision-making competence: an item-level analysis of the Decision Outcome Inventory (DOI)

    PubMed Central

    Parker, Andrew M.; Bruine de Bruin, Wändi; Fischhoff, Baruch

    2015-01-01

    Most behavioral decision research takes place in carefully controlled laboratory settings, and examination of relationships between performance and specific real-world decision outcomes is rare. One prior study shows that people who perform better on hypothetical decision tasks, assessed using the Adult Decision-Making Competence (A-DMC) measure, also tend to experience better real-world decision outcomes, as reported on the Decision Outcomes Inventory (DOI). The DOI score reflects avoidance of outcomes that could result from poor decisions, ranging from serious (e.g., bankruptcy) to minor (e.g., blisters from sunburn). The present analyses go beyond the initial work, which focused on the overall DOI score, by analyzing the relationships between specific decision outcomes and A-DMC performance. Most outcomes are significantly more likely among people with lower A-DMC scores, even after taking into account two variables expected to produce worse real-world decision outcomes: younger age and lower socio-economic status. We discuss the usefulness of DOI as a measure of successful real-world decision-making. PMID:25904876

  6. Temperature data acquired from the DOI/GTN-P Deep Borehole Array on the Arctic Slope of Alaska, 1973-2013

    USGS Publications Warehouse

    Clow, Gary D.

    2014-01-01

    System (GTOS). The data will also be useful for refining our basic understanding of the physical conditions in permafrost in Arctic Alaska, as well as providing important information for validating predictive models used for climate impact assessments. The processed data are available from the Advanced Cooperative Arctic Data and Information Service (ACADIS) repository at doi:10.5065/D6N014HK.

  7. In Preparation of the Nationwide Dissemination of the School-Based Obesity Prevention Program DOiT: Stepwise Development Applying the Intervention Mapping Protocol

    ERIC Educational Resources Information Center

    van Nassau, Femke; Singh, Amika S.; van Mechelen, Willem; Brug, Johannes; Chin A. Paw, Mai J. M.

    2014-01-01

    Background: The school-based Dutch Obesity Intervention in Teenagers (DOiT) program is an evidence-based obesity prevention program. In preparation for dissemination throughout the Netherlands, this study aimed to adapt the initial program and to develop an implementation strategy and materials. Methods: We revisited the Intervention Mapping (IM)…

  8. Negative decision outcomes are more common among people with lower decision-making competence: an item-level analysis of the Decision Outcome Inventory (DOI).

    PubMed

    Parker, Andrew M; Bruine de Bruin, Wändi; Fischhoff, Baruch

    2015-01-01

    Most behavioral decision research takes place in carefully controlled laboratory settings, and examination of relationships between performance and specific real-world decision outcomes is rare. One prior study shows that people who perform better on hypothetical decision tasks, assessed using the Adult Decision-Making Competence (A-DMC) measure, also tend to experience better real-world decision outcomes, as reported on the Decision Outcomes Inventory (DOI). The DOI score reflects avoidance of outcomes that could result from poor decisions, ranging from serious (e.g., bankruptcy) to minor (e.g., blisters from sunburn). The present analyses go beyond the initial work, which focused on the overall DOI score, by analyzing the relationships between specific decision outcomes and A-DMC performance. Most outcomes are significantly more likely among people with lower A-DMC scores, even after taking into account two variables expected to produce worse real-world decision outcomes: younger age and lower socio-economic status. We discuss the usefulness of DOI as a measure of successful real-world decision-making. PMID:25904876

  9. Implemented or Not Implemented? Process Evaluation of the School-Based Obesity Prevention Program DOiT and Associations with Program Effectiveness

    ERIC Educational Resources Information Center

    van Nassau, Femke; Singh, Amika S.; Hoekstra, Trynke; van Mechelen, Willem; Brug, Johannes; Chinapaw, Mai J. M.

    2016-01-01

    This study investigates if and to what extent the Dutch Obesity Intervention in Teenagers (DOiT) program was implemented as intended and how this affected program effectiveness. We collected data at 20 prevocational education schools in the Netherlands. We assessed seven process indicators: recruitment, reach, dosage, fidelity, satisfaction,…

  10. EM International, July 1994, Volume 2

    SciTech Connect

    Not Available

    1994-10-01

    The Office of Environmental Management (EM) at the Department of Energy (DOE) is seeking out and leveraging foreign technology, data, and resources in keeping with EM`s mandate to protect public health and the environment through the safe and cost-effective remediation of the Department`s nuclear weapons sites. EM works closely with foreign governments, industry, and universities to obtain innovative environmental technologies, scientific and engineering expertise, and operations experience that will support EM`s objectives. Where appropriate, these international resources are used to manage the more urgent risks at our sites, secure a safe workplace, help build consensus on critical issues, and strengthen our technology development program. Through international agreements EM engages in cooperative exchange of information, technology, and individuals. Currently, we are managing agreements with a dozen countries in Europe, Latin America, and Asia. These agreements focus on environmental restoration, waste management, transportation of radioactive wastes, and decontamination and decommissioning. This publication contains the following articles: in situ remediation integrated program; in-situ characterization and inspection of tanks; multimedia environmental pollutant assessment system (MEPAS); LLNL wet oxidation -- AEA technology. Besides these articles, this publication covers: EU activities with Russia; technology transfer activities; and international organization activities.

  11. Melatonin reversal of DOI-induced hypophagia in rats; possible mechanism by suppressing 5-HT(2A) receptor-mediated activation of HPA axis.

    PubMed

    Raghavendra, V; Kulkarni, S K

    2000-03-31

    Serotonin type 2A (5-HT(2A)) receptor-mediated neurotransmitter is known to activate hypothalamic-pituitary-adrenal (HPA) axis, regulate sleep-awake cycle, induce anorexia and hyperthermia. Interaction between melatonin and 5-HT(2A) receptors in the regulation of the sleep-awake cycle and head-twitch response in rat have been reported. Previous studies have shown that melatonin has suppressant effect on HPA axis activation, decreases core body temperature and induces hyperphagia in animals. However, melatonin interaction with 5-HT(2A) receptors in mediation of these actions is not yet reported. We have studied the acute effect of melatonin and its antagonist, luzindole on centrally administered (+/-)-1-(2, 5-dimethoxy-4-iodophenyl) 2-amino propane (DOI; a 5-HT(2A/2C) agonist)-induced activation of HPA axis, hypophagia and hyperthermia in 24-h food-deprived rats. Like ritanserin [(1 mg/kg, i.p.) 5-HT(2A/2C) antagonist], peripherally administered melatonin (1.5 and 3 mg/kg, i.p.) did not affect the food intake, rectal temperature or basal adrenal ascorbic acid level. However, pretreatment of rats with it significantly reversed DOI (10 microgram, intraventricular)-induced anorexia and activation of HPA axis. But the hyperthermia induced by DOI was not sensitive to reversal by melatonin. Mel(1) receptor subtype antagonist luzindole (5 microgram, intraventricular) did not modulate the DOI effect but antagonized the melatonin (3 mg/kg, i.p.) reversal of 5-HT(2A) agonist response. The present data suggest that melatonin reversal of DOI-induced hypophagia could be due to suppression of 5-HT(2A) mediated activation of HPA axis. PMID:10727629

  12. NASDA President Isao Uchida shakes hands with STS-87 Mission Specialist Takao Doi, Ph.D., after land

    NASA Technical Reports Server (NTRS)

    1997-01-01

    The president of the National Space Development Agency (NASDA) of Japan, Isao Uchida, at left, shakes hands with STS-87 Mission Specialist Takao Doi, Ph.D., of NASDA, shortly after the landing of Columbia at Kennedy Space Center. STS-87 concluded its mission with a main gear touchdown at 7:20:04 a.m. EST Dec. 5, at KSC's Shuttle Landing Facility Runway 33, drawing the 15-day, 16-hour and 34-minute-long mission of 6.5 million miles to a close. Also onboard the orbiter were Commander Kevin Kregel; Pilot Steven Lindsey; Mission Specialists Winston Scott and Kalpana Chawla, Ph.D.; and Payload Specialist Leonid Kadenyuk of the National Space Agency of Ukraine. During the 88th Space Shuttle mission, the crew performed experiments on the United States Microgravity Payload-4 and pollinated plants as part of the Collaborative Ukrainian Experiment. This was the 12th landing for Columbia at KSC and the 41st KSC landing in the history of the Space Shuttle program.

  13. A Three-Legged Stool or Race? Governance Models for NOAA RISAs, DOI CSCs, and USDA Climate Hubs

    NASA Astrophysics Data System (ADS)

    Foster, J. G.

    2014-12-01

    NOAAs Regional Integrated Sciences and Assessments (RISA) Teams, DOIs Climate Science Centers (CSCs), and USDAs Regional Climate Hubs (RCHs) have common missions of integrating climate and related knowledge across scientific disciplines and regions to create "actionable" information that decision-makes can use to manage climate risks and impacts at state and local scales. However, the sponsoring agency programs, university investigators, and local federal officials govern each differently. The three models of program and center governance are 1) exclusively university (RISAs), 2) a hybrid of Federal government and (host) university (CSCs,), and 3) exclusively Federal (Hubs). Each model has it's advantages and disadvantages in terms of legal definition and authority, scientific mission requirements and strategies, flexibility and legitimacy to conduct research and to collaborate regionally with constituencies, leadership and governance approach and "friction points,", staff capacity and ability to engage stakeholders, necessity to deliver products and services, bureaucratic oversight, performance evaluation, and political support at Congressional, state, and local levels. Using available sources of information and data, this paper will compare and contrast the strengths and weakness of these three regional applied climate science center governance models.

  14. A Three-Legged Stool or Race? Governance Models for NOAA RISAs, DOI CSCs, and USDA Climate Hub

    NASA Astrophysics Data System (ADS)

    Foster, J. G.

    2014-12-01

    NOAAs Regional Integrated Sciences and Assessments (RISA) Teams, DOIs Climate Science Centers (CSCs), and USDAs Regional Climate Hubs (RCHs) have common missions of integrating climate and related knowledge across scientific disciplines and regions to create "actionable" information that decision-makes can use to manage climate risks and impacts at state and local scales. However, the sponsoring agency programs, university investigators, and local federal officials govern each differently. The three models of program and center governance are 1) exclusively university (RISAs), 2) a hybrid of Federal government and (host) university (CSCs,), and 3) exclusively Federal (Hubs). Each model has it's advantages and disadvantages in terms of legal definition and authority, scientific mission requirements and strategies, flexibility and legitimacy to conduct research and to collaborate regionally with constituencies, leadership and governance approach and "friction points,", staff capacity and ability to engage stakeholders, necessity to deliver products and services, bureaucratic oversight, performance evaluation, and political support at Congressional, state, and local levels. Using available sources of information and data, this paper will compare and contrast the strengths and weakness of these three regional applied climate science center governance models.

  15. Many factors complicate EM susceptibility tests

    NASA Astrophysics Data System (ADS)

    Richards, R. J.

    1982-09-01

    Procedures and apparatus currently employed for assaying the EM susceptibility of communication, navigation, and EW equipment are described. Susceptibility is examined in either conducted susceptibility tests, where signals are introduced into the input port of the device under test, or in radiated modes, where the entire device is exposed to an EM field to test for component and system failure. Noting that military standards require up to 10 times the EM resistance as commercial standards, the use of shielded enclosures in both commercial and military testing facilities is explored. RF-tight enclosures are filled with a homogeneous EM field produced by, optimally, broadband generators which emit signals which are amplified to desired levels. Sweep functions permit testing under broadband conditions. Attention is given to radiator selection and antenna choice to produce satisfactory test conditions at all frequencies.

  16. Unified Data Resource for CryoEM

    PubMed Central

    Lawson, Catherine L.

    2010-01-01

    3D cryo-electron microscopy reconstruction methods are uniquely able to reveal structures of many important macromolecules and macromolecular complexes. EMDataBank.org, a joint effort of the Protein Data Bank in Europe (PDBe), the Research Collaboratory for Structural Bioinformatics (RCSB), and the National Center for Macromolecular Imaging (NCMI), is a “one-stop shop” resource for global deposition and retrieval of cryoEM map, model and associated metadata. The resource unifies public access to the two major EM Structural Data archives: EM Data Bank (EMDB) and Protein Data Bank (PDB), and facilitates use of EM structural data of macromolecules and macromolecular complexes by the wider scientific community. PMID:20888470

  17. EMS in Taiwan: past, present, and future.

    PubMed

    Chiang, Wen-Chu; Ko, Patrick Chow-In; Wang, Hui-Chih; Yang, Chi-Wei; Shih, Fuh-Yuan; Hsiung, Kuang-Hua; Ma, Matthew Huei-Ming

    2009-01-01

    Taiwan is a small island country located in East Asia. From around 1995 modern concepts of the EMS were imported and supported by legislation. Considerable progress has since been made towards the construction of an effective pre-hospital care system. This article introduces the current status of the EMS in Taiwan, including the systems, response configurations, funding, personnel, medical directorship, and outcome research. The features and problems of in-hospital emergency care are also discussed. Key areas for further development in the country vary depending on regional differences in available resource and population density. An analysis of the strength, weakness, opportunity, and threats of the evolving EMS in Taiwan could be an example for other countries where the EMS is undergoing a similar process of development and optimisation. PMID:19059690

  18. Vínculos observacionais para o processo-S em estrelas gigantes de Bário

    NASA Astrophysics Data System (ADS)

    Smiljanic, R. H. S.; Porto de Mello, G. F.; da Silva, L.

    2003-08-01

    Estrelas de bário são gigantes vermelhas de tipo GK que apresentam excessos atmosféricos dos elementos do processo-s. Tais excessos são esperados em estrelas na fase de pulsos térmicos do AGB (TP-AGB). As estrelas de bário são, no entanto, menos massivas e menos luminosas que as estrelas do AGB, assim, não poderiam ter se auto-enriquecido. Seu enriquecimento teria origem em uma estrela companheira, inicialmente mais massiva, que evolui pelo TP-AGB, se auto-enriquece com os elementos do processo-s e transfere material contaminado para a atmosfera da atual estrela de bário. A companheira evolui então para anã branca deixando de ser observada diretamente. As estrelas de bário são, portanto, úteis como testes observacionais para teorias de nucleossíntese pelo processo-s, convecção e perda de massa. Análises detalhadas de abundância com dados de alta qualidade para estes objetos são ainda escassas na literatura. Neste trabalho construímos modelos de atmosferas e, procedendo a uma análise diferencial, determinamos parâmetros atmosféricos e evolutivos de uma amostra de dez gigantes de bário e quatro normais. Determinamos seus padrões de abundância para Na, Mg, Al, Si, Ca, Sc, Ti, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, Sr, Y, Zr, Ba, La, Ce, Nd, Sm, Eu e Gd, concluindo que algumas estrelas classificadas na literatura como gigantes de bário são na verdade gigantes normais. Comparamos dois padrões médios de abundância, para estrelas com grandes excessos e estrelas com excessos moderados, com modelos teóricos de enriquecimento pelo processo-s. Os dois grupos de estrelas são ajustados pelos mesmos parâmetros de exposição de nêutrons. Tal resultado sugere que a ocorrência do fenômeno de bário com diferentes intensidades não se deve a diferentes exposições de nêutrons. Discutimos ainda efeitos nucleossintéticos, ligados ao processo-s, sugeridos na literatura para os elementos Cu, Mn, V e Sc.

  19. Superfund Record of Decision (EPA Region 5): U. S. DOI Sangamo/Crab Orchard National Wildlife Refuge, Carterville, IL. (First remedial action), March 1990

    SciTech Connect

    Not Available

    1990-03-30

    The U.S. DOI Sangamo/Crab Orchard NWR site is within the Crab Orchard National Wildlife Refuge, located near Carterville, Illinois. Within the 43,000-acre refuge, lakes and adjacent wetlands support recreational activities on the western portion of the refuge, while the eastern portion is used for manufacturing facilities. DOI leased portions of the refuge to manufacturers of PCB-containing transformers and capacitors, automobile parts, fiberglass boats, plated metal parts, and jet engine starters. Solid wastes generated from these industrial activities were disposed of in onsite landfills, while other liquid wastes may have been discharged into nearby surface waters and impoundments. The primary contaminants of concern affecting the soil, sediment, debris, and sludge are metals including cadmium, chromium, and lead. The selected remedial action for the site is included.

  20. Implemented or not implemented? Process evaluation of the school-based obesity prevention program DOiT and associations with program effectiveness.

    PubMed

    van Nassau, Femke; Singh, Amika S; Hoekstra, Trynke; van Mechelen, Willem; Brug, Johannes; Chinapaw, Mai J M

    2016-04-01

    This study investigates if and to what extent the Dutch Obesity Intervention in Teenagers (DOiT) program was implemented as intended and how this affected program effectiveness. We collected data at 20 prevocational education schools in the Netherlands. We assessed seven process indicators: recruitment, reach, dosage, fidelity, satisfaction, effectiveness and continuation. Data collection involved teacher questionnaires (n= 110), adolescent questionnaires and adiposity measures (n= 938). Using multi-level confirmatory factor analyses, we applied an innovative method to obtain explorative implementation index scores. The percentage of accomplished activities ranged from 9% (for 'closure meeting') up to 93% (for 'obtaining support within the school for adoption'). The percentage of lessons delivered decreased from 74 to 18% towards the end of the program. Fidelity to the teacher manual ranged from 85 to 26%. In general, teachers were satisfied with the DOiT lessons and teaching materials. Despite teachers' satisfaction with the DOiT lessons and teaching materials, degree of program implementation was lower than expected, especially towards the end of the program. Further, some evidence was found for an association between a higher implementation index score and program effectiveness, but more research is needed to test the validity of the implementation index. PMID:27004906

  1. EMS adaptation for climate change

    NASA Astrophysics Data System (ADS)

    Pan, C.; Chang, Y.; Wen, J.; Tsai, M.

    2010-12-01

    The purpose of this study was to find an appropriate scenario of pre-hospital transportation of an emergency medical service (EMS) system for burdensome casualties resulting from extreme climate events. A case of natural catastrophic events in Taiwan, 88 wind-caused disasters, was reviewed and analyzed. A sequential-conveyance method was designed to shorten the casualty transportation time and to promote the efficiency of ambulance services. A proposed mobile emergency medical center was first constructed in a safe area, but nearby the disaster area. The Center consists of professional medical personnel who process the triage of incoming patients and take care of casualties with minor injuries. Ambulances in the Center were ready to sequentially convey the casualties with severer conditions to an assigned hospital that is distant from the disaster area for further treatment. The study suggests that if we could construct a spacious and well-equipped mobile emergency medical center, only a small portion of casualties would need to be transferred to distant hospitals. This would reduce the over-crowding problem in hospital ERs. First-line ambulances only reciprocated between the mobile emergency medical center and the disaster area, saving time and shortening the working distances. Second-line ambulances were highly regulated between the mobile emergency medical center and requested hospitals. The ambulance service of the sequential-conveyance method was found to be more efficient than the conventional method and was concluded to be more profitable and reasonable on paper in adapting to climate change. Therefore, additional practical work should be launched to collect more precise quantitative data.

  2. Development of 1.45-mm resolution four-layer DOI-PET detector for simultaneous measurement in 3T MRI.

    PubMed

    Nishikido, Fumihiko; Tachibana, Atsushi; Obata, Takayuki; Inadama, Naoko; Yoshida, Eiji; Suga, Mikio; Murayama, Hideo; Yamaya, Taiga

    2015-01-01

    Recently, various types of PET-MRI systems have been developed by a number of research groups. However, almost all of the PET detectors used in these PET-MRI systems have no depth-of-interaction (DOI) capability. The DOI detector can reduce the parallax error and lead to improvement of the performance. We are developing a new PET-MRI system which consists of four-layer DOI detectors positioned close to the measured object to achieve high spatial resolution and high scanner sensitivity. As a first step, we are investigating influences the PET detector and the MRI system have on each other using a prototype four-layer DOI-PET detector. This prototype detector consists of a lutetium yttrium orthosilicate crystal block and a 4 × 4 multi-pixel photon counter array. The size of each crystal element is 1.45 mm × 1.45 mm × 4.5 mm, and the crystals are arranged in 6 × 6 elements × 4 layers with reflectors. The detector and some electric components are packaged in an aluminum shielding box. Experiments were carried out with 3.0 T MRI (GE, Signa HDx) and a birdcage-type RF coil. We demonstrated that the DOI-PET detector was normally operated in simultaneous measurements with no influence of the MRI measurement. A slight influence of the PET detector on the static magnetic field of the MRI was observed near the PET detector. The signal-to-noise ratio was decreased by presence of the PET detector due to environmental noise entering the MRI room through the cables, even though the PET detector was not powered up. On the other hand, no influence of electric noise from the PET detector in the simultaneous measurement on the MRI images was observed, even though the PET detector was positioned near the RF coil. PMID:25348721

  3. A DOI Detector With Crystal Scatter Identification Capability for High Sensitivity and High Spatial Resolution PET Imaging

    PubMed Central

    Gu, Z.; Prout, D. L.; Silverman, R. W.; Herman, H.; Dooraghi, A.; Chatziioannou, A. F.

    2015-01-01

    potentially lead to a high spatial resolution, high sensitivity and DOI PET system. PMID:26478600

  4. 10 CFR Appendixes E-M to Part 52 - [Reserved

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 2 2010-01-01 2010-01-01 false E Appendixes E-M to Part 52 Energy NUCLEAR REGULATORY COMMISSION (CONTINUED) LICENSES, CERTIFICATIONS, AND APPROVALS FOR NUCLEAR POWER PLANTS Appendixes E-M to Part 52...

  5. 10 CFR Appendixes E-M to Part 52 - [Reserved

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 10 Energy 2 2014-01-01 2014-01-01 false E Appendixes E-M to Part 52 Energy NUCLEAR REGULATORY COMMISSION (CONTINUED) LICENSES, CERTIFICATIONS, AND APPROVALS FOR NUCLEAR POWER PLANTS Appendixes E-M to Part 52...

  6. 10 CFR Appendixes E-M to Part 52 - [Reserved

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 10 Energy 2 2012-01-01 2012-01-01 false E Appendixes E-M to Part 52 Energy NUCLEAR REGULATORY COMMISSION (CONTINUED) LICENSES, CERTIFICATIONS, AND APPROVALS FOR NUCLEAR POWER PLANTS Appendixes E-M to Part 52...

  7. 10 CFR Appendixes E-M to Part 52 - [Reserved

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 10 Energy 2 2013-01-01 2013-01-01 false E Appendixes E-M to Part 52 Energy NUCLEAR REGULATORY COMMISSION (CONTINUED) LICENSES, CERTIFICATIONS, AND APPROVALS FOR NUCLEAR POWER PLANTS Appendixes E-M to Part 52...

  8. 10 CFR Appendixes E-M to Part 52 - [Reserved

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Energy 2 2011-01-01 2011-01-01 false E Appendixes E-M to Part 52 Energy NUCLEAR REGULATORY COMMISSION (CONTINUED) LICENSES, CERTIFICATIONS, AND APPROVALS FOR NUCLEAR POWER PLANTS Appendixes E-M to Part 52...

  9. Processing of Cryo-EM Movie Data.

    PubMed

    Ripstein, Z A; Rubinstein, J L

    2016-01-01

    Direct detector device (DDD) cameras dramatically enhance the capabilities of electron cryomicroscopy (cryo-EM) due to their improved detective quantum efficiency (DQE) relative to other detectors. DDDs use semiconductor technology that allows micrographs to be recorded as movies rather than integrated individual exposures. Movies from DDDs improve cryo-EM in another, more surprising, way. DDD movies revealed beam-induced specimen movement as a major source of image degradation and provide a way to partially correct the problem by aligning frames or regions of frames to account for this specimen movement. In this chapter, we use a self-consistent mathematical notation to explain, compare, and contrast several of the most popular existing algorithms for computationally correcting specimen movement in DDD movies. We conclude by discussing future developments in algorithms for processing DDD movies that would extend the capabilities of cryo-EM even further. PMID:27572725

  10. Risk Communication Within the EM Program

    SciTech Connect

    Edelson, M.

    2003-02-26

    The U.S. Department of Energy Environmental Management program (EM) conducts the most extensive environmental remediation effort in the world. The annual EM budgets have exceeded $6,000,000,000 for approximately ten years and EM has assumed responsibility for the cleanup of the largest DOE reservations (i.e., at Hanford, Washington, Aiken, South Carolina, and Idaho Falls, Idaho) as well as the facilities at Rocky Flats, Colorado and in Ohio. Each of these sites has areas of extensive radioactive and chemical contamination, numerous surplus facilities that require decontamination and removal, while some have special nuclear material that requires secure storage. The EM program has been criticized for being ineffective (1) and has been repeatedly reorganized to address perceived shortcomings. The most recent reorganization was announced in 2001 to become effective at the beginning of the 2003 Federal Fiscal Year (i.e., October 2002). It was preceded by a ''top to bottom'' review (TTBR) of the program (2) that identified several deficiencies that were to be corrected as a result of the reorganization. One prominent outcome of the TTBR was the identification of ''risk reduction'' as an organizing principle to prioritize the activities of the new EM program. The new program also sought to accelerate progress by identifying a set of critical activities at each site that could be accelerated and result in more rapid site closure, with attendant risk, cost, and schedule benefits. This paper investigates how the new emphasis on risk reduction in the EM program has been communicated to EM stakeholders and regulators. It focuses on the Rocky Flats Environmental Technology Site (RFETS) as a case study and finds that there is little evidence for a new emphasis on risk reduction in EM communications with RFETS stakeholders. Discussions between DOE and RFETS stakeholders often refer to ''risk,'' but the word serves as a placeholder for other concepts. Thus ''risk'' communication

  11. Plagiarism in the article Emphysematous cystitis and emphysematous pyelitis: a clinically misleading association. Mustapha Ahsaini et al. The Pan African Medical Journal. 2013;16:18. (doi:10.11604/pamj.2013.16.18.2505).

    PubMed

    2015-01-01

    This retracts article Emphysematous cystitis and emphysematous pyelitis: a clinically misleading association. Mustapha Ahsaini, Amadou Kassogue, Mohammed Fadl Tazi, Anas Zaougui, Jalal Edine Elammari, Abdelhak Khallouk, Mohammed Jamal El Fassi, My Hassan Farih. The Pan African Medical Journal. 2013;16:18. (doi:10.11604/pamj.2013.16.18.2505).[This retracts the article DOI: 10.11604/pamj.2013.16.18.2505.]. PMID:26328003

  12. Feasibility of a brain-dedicated PET-MRI system using four-layer DOI detectors integrated with an RF head coil

    NASA Astrophysics Data System (ADS)

    Nishikido, F.; Obata, T.; Shimizu, K.; Suga, M.; Inadama, N.; Tachibana, A.; Yoshida, E.; Ito, H.; Yamaya, T.

    2014-08-01

    We are developing a PET-MRI system which consists of PET detectors integrated with the head coil of the MRI in order to realize high spatial resolution and high sensitivity in simultaneous measurements. In the PET-MRI system, the PET detectors which consist of a scintillator block, photo-detectors and front-end circuits with four-layer depth-of-interaction (DOI) encoding capability are placed close to the measured object. Therefore, the proposed system can achieve high sensitivity without degradation of spatial resolution at the edge of the field-of-view due to parallax error thanks to the four-layer DOI capability. In this paper, we fabricated a prototype system which consists of a prototype four-layer DOI-PET detector, a dummy PET detector and a prototype birdcage type head coil. Then we used the prototype system to evaluate the performance of the four-layer DOI-PET detector and the reciprocal influence between the PET detectors and MRI images. The prototype DOI-PET detector consists of six monolithic multi-pixel photon counter (MPPC) arrays (S11064-050P), a readout circuit board, two scintillator blocks and a copper shielding box. Each scintillator block consists of four layers of Lu1.8Gd0.2SiO5:Ce (LGSO) scintillators and reflectors are inserted between the scintillation crystals. The dummy detector has all these components except the two scintillator blocks. The head coil is dedicated to a 3.0 T MRI (MAGNETOM Verio, Siemens) and the two detectors are mounted in gaps between head coil elements. Energy resolution and crystal identification performance of the prototype four-layer DOI-PET detector were evaluated with and without MRI measurements by the gradient echo and spin echo methods. We identified crystal elements in all four layers from a 2D flood histogram and energy resolution of 15-18% was obtained for single crystal elements in simultaneous measurements. The difference between the average energy resolutions and photo-peak positions with and without MRI

  13. Do earthquakes generate EM signals?

    NASA Astrophysics Data System (ADS)

    Walter, Christina; Onacha, Stephen; Malin, Peter; Shalev, Eylon; Lucas, Alan

    2010-05-01

    study areas, large swarms of earthquakes were located very close to the electromagnetic coils. This abstract focuses on the data from the Wairakei area. Preliminary data analysis has been carried out by band pass filtering and removing of the harmonics of the 50 Hz power line frequency. The initial results clearly show that electromagnetic signals accompany the seismic P and S waves (coseismic signal). Further data analysis involves the extraction of the seismoelectric signal generated at the onset of the earthquake and at interfaces from the coseismic signal and other ‘noise' sources. This processing step exhibits a major challenge in seismoelectric data processing. Unlike in other studies we measured the EM field and the seismic field at one location. Therefore the seismoelectric wave travelling at the speed of light cannot be determined as easily in the arrival times as when an array of coils is used. This makes the determination of the origin time much more difficult. Hence other processing techniques need to be explored.

  14. Reply to: "Palmitoylethanolamide: problems regarding micronization, ultra-micronization and additives" Inflammopharmacology DOI:10.1007/s10787-014-0202-3.

    PubMed

    Skaper, Stephen D; Facci, Laura; Fusco, Mariella; Della Valle, Maria Federica; Zusso, Morena; Costa, Barbara; Giusti, Pietro

    2015-06-01

    This is a reply to a recently published Commentary: "Palmitoylethanolamide: problems regarding micronization, ultra-micronization and additives" Inflammopharmacology DOI: 10.1007/s10787-014-0202-3 , written in relation to our review article: Skaper SD, Facci L, Fusco M, della Valle MF, Zusso M, Costa B, Giusti P (2014) "Palmitoylethanolamide, a naturally occurring disease-modifying agent in neuropathic pain" Inflammopharmacology 22:79-94 DOI: 10.1007/s10787-013-0191-7 . We believe that the Commentary by Kriek contains a number of erroneous statements and misinterpretations of the published scientific/medical literature which our reply shall elaborate on. Further, the writer of the Commentary has a direct connection to a company, JP Russell Science Ltd that sells palmitoylethanolamide. The take-home message of our review remains as originally stated: "Collectively, the findings presented here propose that palmitoylethanolamide merits further consideration as a disease-modifying agent for controlling inflammatory responses and related chronic and neuropathic pain". PMID:24862356

  15. Autoradiographic characterization of (+-)-1-(2,5-dimethoxy-4-( sup 125 I) iodophenyl)-2-aminopropane (( sup 125 I)DOI) binding to 5-HT2 and 5-HT1c receptors in rat brain

    SciTech Connect

    Appel, N.M.; Mitchell, W.M.; Garlick, R.K.; Glennon, R.A.; Teitler, M.; De Souza, E.B. )

    1990-11-01

    The 5-HT2 (serotonin) receptor has traditionally been labeled with antagonist radioligands such as (3H)ketanserin and (3H)spiperone, which label both agonist high-affinity (guanyl nucleotide-sensitive) and agonist low-affinity (guanyl nucleotide-insensitive) states of this receptor. The hallucinogen 1-(2,5-dimethoxy-4-iodophenyl)-2-aminopropane (DOI) is an agonist which labels the high-affinity guanyl nucleotide-sensitive state of brain 5-HT2 receptors selectively. In the present study, conditions for autoradiographic visualization of (+/-)-(125I)DOI-labeled 5-HT2 receptors were optimized and binding to slide-mounted sections was characterized with respect to pharmacology, guanyl nucleotide sensitivity and anatomical distribution. In slide-mounted rat brain sections (+/-)-(125I)DOI binding was saturable, of high affinity (KD approximately 4 nM) and displayed a pharmacologic profile typical of 5-HT2 receptors. Consistent with coupling of 5-HT2 receptors in the high-affinity state to a guanyl nucleotide regulatory protein, (125I)DOI binding was inhibited by guanyl nucleotides but not by adenosine triphosphate. Patterns of autoradiographic distribution of (125I)DOI binding to 5-HT2 receptors were similar to those seen with (3H)ketanserin- and (125I)-lysergic acid diethylamide-labeled 5-HT2 receptors. However, the density of 5-HT2 receptors labeled by the agonist (125I)DOI was markedly lower (30-50%) than that labeled by the antagonist (3H)ketanserin. High densities of (125I)DOI labeling were present in olfactory bulb, anterior regions of cerebral cortex (layer IV), claustrum, caudate putamen, globus pallidus, ventral pallidum, islands of Calleja, mammillary nuclei and inferior olive. Binding in hippocampus, thalamus and hypothalamus was generally sparse.

  16. The E-MS Algorithm: Model Selection with Incomplete Data

    PubMed Central

    Jiang, Jiming; Nguyen, Thuan; Rao, J. Sunil

    2014-01-01

    We propose a procedure associated with the idea of the E-M algorithm for model selection in the presence of missing data. The idea extends the concept of parameters to include both the model and the parameters under the model, and thus allows the model to be part of the E-M iterations. We develop the procedure, known as the E-MS algorithm, under the assumption that the class of candidate models is finite. Some special cases of the procedure are considered, including E-MS with the generalized information criteria (GIC), and E-MS with the adaptive fence (AF; Jiang et al. 2008). We prove numerical convergence of the E-MS algorithm as well as consistency in model selection of the limiting model of the E-MS convergence, for E-MS with GIC and E-MS with AF. We study the impact on model selection of different missing data mechanisms. Furthermore, we carry out extensive simulation studies on the finite-sample performance of the E-MS with comparisons to other procedures. The methodology is also illustrated on a real data analysis involving QTL mapping for an agricultural study on barley grains. PMID:26783375

  17. Experiências internacionais da aplicação de sistemas de apoio à decisão clínica em gastroenterologia

    PubMed Central

    Tenório, Josceli Maria; Hummel, Anderson Diniz; Sdepanian, Vera Lucia; Pisa, Ivan Torres; de Fátima Marin, Heimar

    2015-01-01

    Objetivo Descrever as experiências recentes com a aplicação de sistemas de apoio à decisão clínica em gastroenterologia, de forma a estabelecer o nível de desenvolvimento, testes e vantagens conferidas à prática médica com a introdução desses softwares. Métodos Foi realizada busca nas bases de dados PubMed, LILACS e ISI Web of Knowledge, utilizando termos relacionados à sistemas de apoio à decisão e à gastroenterogia, incluindo artigos originais publicados no período entre 2005 e 2010. Foram recuperadas 104 publicações, na busca inicial e, após a aplicação dos critérios de inclusão e exclusão, foram eleitos nove estudos para leitura do texto completo. Resultados Os sistemas de apoio à decisão clínica apresentam grande multiplicidade de problemas clínicos e investigação de doenças. Em 89% dos casos, são descritos modelos experimentais para o desenvolvimento de sistemas de apoio à decisão clínica. A descrição dos resultados obtidos por técnicas de inteligência artificial em 78% das publicações. Em dois dos estudos foram realizadas comparações com o médico e em apenas uma publicação um estudo controlado foi descrito, mostrando evidências de melhorias na prática médica. Conclusão Os estudos mostram potenciais benefícios dos sistemas de apoio à decisão clínica à prática médica, porém, estudos controlados em ambiente real devem ser realizados para comprovar esta perspectiva. PMID:26491625

  18. Percutaneous absorption and disposition of Tinopal EMS.

    PubMed

    Black, J G; Moule, R C; Philp, J

    1977-08-01

    A cotton-substantive, anionic, fluorescent whitening agent manufactured by several suppliers under various trade names e.g. Tinopal EMS, has been synthesized in radioactive form. Intubation of detergent or aqueous solution into rats resulted in little absorption from the intestinal tract as evidenced by low radioactivity in the urine and tissues. Most of the dose was excreted rapidly in the faeces. After parenteral administration to rats, the radioactivity was rapidly excreted in the faeces with small amounts remaining in tissues and organs. There was slight evidence of retention of radioactivity in the kidneys. Very small amounts of Tinopal EMS in detergent were absorbed through rat skin, but only when concentrations greater than those normally used by the consumer, together with occlusion of the skin were employed. Small amounts were absorbed throught skin when applied in ethanol. It is concluded that the possibility of systemic toxic effects in man as a result of percutaneous absorption is remote. PMID:929616

  19. Crosshole EM in steel-cased boreholes

    SciTech Connect

    Wilt, M.; Lee, K.H.; Becker, A.; Spies, B.; Wang, B.

    1996-07-01

    The application of crosshole EM methods through steel well-casing was investigated in theoretical, laboratory and field studies. A numerical code was developed that calculates the attenuation and phase delay of an EM dipole signal propagated through a steel well casing lodged in a homogeneous medium. The code was validated with a scale model and used for sensitivity studies of casing and formation properties. Finally, field measurements were made in an oil field undergoing waterflooding. Our most important findings are that (1) crosshole surveys are feasible using a well pair with one metallic and one non-metallic casing. (2) The casing effect seems be localized within the pipe section that includes the sensor. (3) The effects of the casing can be corrected using simple means and (4) crosshole field data that are sensitive to both formation and casing were acquired in a working environment.

  20. TandEM: Titan and Enceladus mission

    USGS Publications Warehouse

    Coustenis, A.; Atreya, S.K.; Balint, T.; Brown, R.H.; Dougherty, M.K.; Ferri, F.; Fulchignoni, M.; Gautier, D.; Gowen, R.A.; Griffith, C.A.; Gurvits, L.I.; Jaumann, R.; Langevin, Y.; Leese, M.R.; Lunine, J.I.; McKay, C.P.; Moussas, X.; Muller-Wodarg, I.; Neubauer, F.; Owen, T.C.; Raulin, F.; Sittler, E.C.; Sohl, F.; Sotin, C.; Tobie, G.; Tokano, T.; Turtle, E.P.; Wahlund, J.-E.; Waite, J.H.; Baines, K.H.; Blamont, J.; Coates, A.J.; Dandouras, I.; Krimigis, T.; Lellouch, E.; Lorenz, R.D.; Morse, A.; Porco, C.C.; Hirtzig, M.; Saur, J.; Spilker, T.; Zarnecki, J.C.; Choi, E.; Achilleos, N.; Amils, R.; Annan, P.; Atkinson, D.H.; Benilan, Y.; Bertucci, C.; Bezard, B.; Bjoraker, G.L.; Blanc, M.; Boireau, L.; Bouman, J.; Cabane, M.; Capria, M.T.; Chassefiere, E.; Coll, P.; Combes, M.; Cooper, J.F.; Coradini, A.; Crary, F.; Cravens, T.; Daglis, I.A.; de Angelis, E.; De Bergh, C.; de Pater, I.; Dunford, C.; Durry, G.; Dutuit, O.; Fairbrother, D.; Flasar, F.M.; Fortes, A.D.; Frampton, R.; Fujimoto, M.; Galand, M.; Grasset, O.; Grott, M.; Haltigin, T.; Herique, A.; Hersant, F.; Hussmann, H.; Ip, W.; Johnson, R.; Kallio, E.; Kempf, S.; Knapmeyer, M.; Kofman, W.; Koop, R.; Kostiuk, T.; Krupp, N.; Kuppers, M.; Lammer, H.; Lara, L.-M.; Lavvas, P.; Le, Mouelic S.; Lebonnois, S.; Ledvina, S.; Li, J.; Livengood, T.A.; Lopes, R.M.; Lopez-Moreno, J. -J.; Luz, D.; Mahaffy, P.R.; Mall, U.; Martinez-Frias, J.; Marty, B.; McCord, T.; Salvan, C.M.; Milillo, A.; Mitchell, D.G.; Modolo, R.; Mousis, O.; Nakamura, M.; Neish, C.D.; Nixon, C.A.; Mvondo, D.N.; Orton, G.; Paetzold, M.; Pitman, J.; Pogrebenko, S.; Pollard, W.; Prieto-Ballesteros, O.; Rannou, P.; Reh, K.; Richter, L.; Robb, F.T.; Rodrigo, R.; Rodriguez, S.; Romani, P.; Bermejo, M.R.; Sarris, E.T.; Schenk, P.; Schmitt, B.; Schmitz, N.; Schulze-Makuch, D.; Schwingenschuh, K.; Selig, A.; Sicardy, B.; Soderblom, L.; Spilker, L.J.; Stam, D.; Steele, A.; Stephan, K.; Strobel, D.F.; Szego, K.; Szopa

    2009-01-01

    TandEM was proposed as an L-class (large) mission in response to ESA's Cosmic Vision 2015-2025 Call, and accepted for further studies, with the goal of exploring Titan and Enceladus. The mission concept is to perform in situ investigations of two worlds tied together by location and properties, whose remarkable natures have been partly revealed by the ongoing Cassini-Huygens mission. These bodies still hold mysteries requiring a complete exploration using a variety of vehicles and instruments. TandEM is an ambitious mission because its targets are two of the most exciting and challenging bodies in the Solar System. It is designed to build on but exceed the scientific and technological accomplishments of the Cassini-Huygens mission, exploring Titan and Enceladus in ways that are not currently possible (full close-up and in situ coverage over long periods of time). In the current mission architecture, TandEM proposes to deliver two medium-sized spacecraft to the Saturnian system. One spacecraft would be an orbiter with a large host of instruments which would perform several Enceladus flybys and deliver penetrators to its surface before going into a dedicated orbit around Titan alone, while the other spacecraft would carry the Titan in situ investigation components, i.e. a hot-air balloon (Montgolfi??re) and possibly several landing probes to be delivered through the atmosphere. ?? Springer Science + Business Media B.V. 2008.

  1. Helicopter EMS: Research Endpoints and Potential Benefits

    PubMed Central

    Thomas, Stephen H.; Arthur, Annette O.

    2012-01-01

    Patients, EMS systems, and healthcare regions benefit from Helicopter EMS (HEMS) utilization. This article discusses these benefits in terms of specific endpoints utilized in research projects. The endpoint of interest, be it primary, secondary, or surrogate, is important to understand in the deployment of HEMS resources or in planning further HEMS outcomes research. The most important outcomes are those which show potential benefits to the patients, such as functional survival, pain relief, and earlier ALS care. Case reports are also important “outcomes” publications. The benefits of HEMS in the rural setting is the ability to provide timely access to Level I or Level II trauma centers and in nontrauma, interfacility transport of cardiac, stroke, and even sepsis patients. Many HEMS crews have pharmacologic and procedural capabilities that bring a different level of care to a trauma scene or small referring hospital, especially in the rural setting. Regional healthcare and EMS system's benefit from HEMS by their capability to extend the advanced level of care throughout a region, provide a “backup” for areas with limited ALS coverage, minimize transport times, make available direct transport to specialized centers, and offer flexibility of transport in overloaded hospital systems. PMID:22203905

  2. Uma Comparação entre Técnicas de Propagação de Erros em Astrofísica: Monte Carlo x Bootstrap

    NASA Astrophysics Data System (ADS)

    Zabot, Alexandre; Baptista, Raymundo

    2005-07-01

    Neste trabalho é feito um estudo comparativo entre dois algoritmos numéricos usados para propagação de erros em dados experimentais. Um deles é conhecido por Método de Monte carlo e o outro por Método de Bootstrap. Recentemente, Dhullon & Watson argüiram que a aplicação do método de Monte Carlo introduz ruído nos dados, e propuseram então a utilização do Bootstrap como alternativa capaz de produzir resultados superiores. O objetivo deste trabalho é testar a validade dessa afirmação. As duas técnicas foram aplicadas a três problemas diferentes: o ajsute de modelos de emissão LTE simples e atmosfera estelar a espectros estelares observados e o ajuste de curvas de luz de eclipses de Variáveis Cataclísmicas para a detemrinação da distribuição radial de brilho dos seus discos de acréscimo. Os métodos foram testados quanto à sua robusteza, ou seja, a capacidade de prover resultados coerentes enre si. Além disso, as soluções dos métodos foram comparadas. Os resultados indicam que não existe evidência de superioridade de um métodos em relação ao outro.

  3. Test beam performance of CDF plug upgrade EM calorimeter

    SciTech Connect

    Fukui, Y.; CDF Upgrade Group

    1998-01-01

    CDF Plug Upgrade(tile-fiber) EM Calorimeter performed resolution of 15%/{radical}E{circle_plus}0.7% with non-linearity less than 1% in a energy range of 5-180 GeV at Fermilab Test Beam. Transverse uniformity of inside-tower-response of the EM Calorimeter was 2.2% with 56 GeV positron, which was reduced to 1.0% with response map correction. We observed 300 photo electron/GeV in the EM Calorimeter. Ratios of EM Calorimeter response to positron beam to that to {sup 137}Cs Source was stable within 1% in the period of 8 months.

  4. 2. HI PAR (ACQUISITION RADAR) TOWER AND ENLISTED MEN (EM) ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    2. HI PAR (ACQUISITION RADAR) TOWER AND ENLISTED MEN (EM) BARRACKS WITH RADAR ATTACHED. - Nike Hercules Missile Battery Summit Site, Battery Control Administration & Barracks Building, Anchorage, Anchorage, AK

  5. Sub-millimetre DOI detector based on monolithic LYSO and digital SiPM for a dedicated small-animal PET system.

    PubMed

    Marcinkowski, Radosław; Mollet, Pieter; Van Holen, Roel; Vandenberghe, Stefaan

    2016-03-01

    The mouse model is widely used in a vast range of biomedical and preclinical studies. Thanks to the ability to detect and quantify biological processes at the molecular level in vivo, PET has become a well-established tool in these investigations. However, the need to visualize and quantify radiopharmaceuticals in anatomic structures of millimetre or less requires good spatial resolution and sensitivity from small-animal PET imaging systems.In previous work we have presented a proof-of-concept of a dedicated high-resolution small-animal PET scanner based on thin monolithic scintillator crystals and Digital Photon Counter photosensor. The combination of thin monolithic crystals and MLE positioning algorithm resulted in an excellent spatial resolution of 0.7 mm uniform in the entire field of view (FOV). However, the limitation of the scanner was its low sensitivity due to small thickness of the lutetium-yttrium oxyorthosilicate (LYSO) crystals (2 mm).Here we present an improved detector design for a small-animal PET system that simultaneously achieves higher sensitivity and sustains a sub-millimetre spatial resolution. The proposed detector consists of a 5 mm thick monolithic LYSO crystal optically coupled to a Digital Photon Counter. Mean nearest neighbour (MNN) positioning combined with depth of interaction (DOI) decoding was employed to achieve sub-millimetre spatial resolution. To evaluate detector performance the intrinsic spatial resolution, energy resolution and coincidence resolving time (CRT) were measured. The average intrinsic spatial resolution of the detector was 0.60 mm full-width-at-half-maximum (FWHM). A DOI resolution of 1.66 mm was achieved. The energy resolution was 23% FWHM at 511 keV and CRT of 529 ps were measured. The improved detector design overcomes the sensitivity limitation of the previous design by increasing the nominal sensitivity of the detector block and retains an excellent intrinsic spatial resolution. PMID:26907952

  6. Communication - An Effective Tool for Implementing ISO 14001/EMS

    SciTech Connect

    Rachel Damewood; Bowen Huntsman

    2004-04-01

    The Idaho National Engineering and Environmental Laboratory (INEEL) received ISO 14001/EMS certification in June 2002. Communication played an effective role in implementing ISO 14001/EMS at the INEEL. This paper describes communication strategies used during the implementation and certification processes. The INEEL achieved Integrated Safety Management System (ISMS) and Voluntary Protection Program (VPP) Star status in 2001. ISMS implemented a formal process to plan and execute work. VPP facilitated worker involvement by establishing geographic units at various facilities with employee points of contact and management champions. The INEEL Environmental Management System (EMS) was developed to integrate the environmental functional area into its ISMS and VPP. Since the core functions of ISMS, VPP, and EMS are interchangeable, they were easy to integrate. Communication is essential to successfully implement an EMS. (According to ISO 14001 requirements, communication interacts with 12 other elements of the requirements.) We developed communication strategies that integrated ISMS, VPP, and EMS. For example, the ISMS, VPP, and EMS Web sites communicated messages to the work force, such as “VPP emphasizes the people side of doing business, ISMS emphasizes the system side of doing business, and EMS emphasizes the systems to protect the environment; but they all define work, identify and analyze hazards, and mitigate the hazards.” As a result of this integration, the work force supported and implemented the EMS. In addition, the INEEL established a cross-functional communication team to assist with implementing the EMS. The team included members from the Training and Communication organizations, VPP office, Pollution Prevention, Employee and Media Relations, a union representative, facility environmental support, and EMS staff. This crossfunctional team used various communication strategies to promote our EMS to all organization levels and successfully implemented EMS

  7. Comment on ``Mixed convection boundary layer flow over a horizontal plate with thermal radiation'' by A. Ishak, Heat Mass Transfer, DOI 10.1007/s00231-009-0552-3

    NASA Astrophysics Data System (ADS)

    Magyari, Eugen

    2010-10-01

    In a recent paper of Ishak (Heat Mass Transfer, doi: 10.1007/s00231-009-0552-3 DOI"/> , 2009) the similarity solutions of the title problem have been investigated numerically in some detail. The present note shows, however, that with the aid of a simple rescaling of the Prandtl number, the results reported by Ishak can easily be recovered from the well known solution of the same problem, without the effect of thermal radiation.

  8. EM threat analysis for wireless systems.

    SciTech Connect

    Burkholder, R. J. (Ohio State University Electroscience Laboratory); Mariano, Robert J.; Schniter, P. (Ohio State University Electroscience Laboratory); Gupta, I. J. (Ohio State University Electroscience Laboratory)

    2006-06-01

    Modern digital radio systems are complex and must be carefully designed, especially when expected to operate in harsh propagation environments. The ability to accurately predict the effects of propagation on wireless radio performance could lead to more efficient radio designs as well as the ability to perform vulnerability analyses before and after system deployment. In this report, the authors--experts in electromagnetic (EM) modeling and wireless communication theory--describe the construction of a simulation environment that is capable of quantifying the effects of wireless propagation on the performance of digital communication.

  9. Stochastic EM-based TFBS motif discovery with MITSU

    PubMed Central

    Kilpatrick, Alastair M.; Ward, Bruce; Aitken, Stuart

    2014-01-01

    Motivation: The Expectation–Maximization (EM) algorithm has been successfully applied to the problem of transcription factor binding site (TFBS) motif discovery and underlies the most widely used motif discovery algorithms. In the wider field of probabilistic modelling, the stochastic EM (sEM) algorithm has been used to overcome some of the limitations of the EM algorithm; however, the application of sEM to motif discovery has not been fully explored. Results: We present MITSU (Motif discovery by ITerative Sampling and Updating), a novel algorithm for motif discovery, which combines sEM with an improved approximation to the likelihood function, which is unconstrained with regard to the distribution of motif occurrences within the input dataset. The algorithm is evaluated quantitatively on realistic synthetic data and several collections of characterized prokaryotic TFBS motifs and shown to outperform EM and an alternative sEM-based algorithm, particularly in terms of site-level positive predictive value. Availability and implementation: Java executable available for download at http://www.sourceforge.net/p/mitsu-motif/, supported on Linux/OS X. Contact: a.m.kilpatrick@sms.ed.ac.uk PMID:24931999

  10. CryoEM at IUCrJ: a new era

    PubMed Central

    Subramaniam, Sriram; Kühlbrandt, Werner; Henderson, Richard

    2016-01-01

    In this overview, we briefly outline recent advances in electron cryomicroscopy (cryoEM) and explain why the journal IUCrJ, published by the International Union of Crystallography, could provide a natural home for publications covering many present and future developments in the cryoEM field. PMID:26870375

  11. 7 CFR 1945.20 - Making EM loans available.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... Secretary in making a decision on the requested natural disaster determination. (4) The Secretary will... 7 Agriculture 13 2012-01-01 2012-01-01 false Making EM loans available. 1945.20 Section 1945.20...) PROGRAM REGULATIONS (CONTINUED) EMERGENCY Disaster Assistance-General § 1945.20 Making EM loans...

  12. 7 CFR 1945.20 - Making EM loans available.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... Secretary in making a decision on the requested natural disaster determination. (4) The Secretary will... 7 Agriculture 13 2011-01-01 2009-01-01 true Making EM loans available. 1945.20 Section 1945.20...) PROGRAM REGULATIONS (CONTINUED) EMERGENCY Disaster Assistance-General § 1945.20 Making EM loans...

  13. Click-EM for imaging metabolically tagged nonprotein biomolecules.

    PubMed

    Ngo, John T; Adams, Stephen R; Deerinck, Thomas J; Boassa, Daniela; Rodriguez-Rivera, Frances; Palida, Sakina F; Bertozzi, Carolyn R; Ellisman, Mark H; Tsien, Roger Y

    2016-06-01

    EM has long been the main technique for imaging cell structures with nanometer resolution but has lagged behind light microscopy in the crucial ability to make specific molecules stand out. Here we introduce click-EM, a labeling technique for correlative light microscopy and EM imaging of nonprotein biomolecules. In this approach, metabolic labeling substrates containing bioorthogonal functional groups are provided to cells for incorporation into biopolymers by endogenous biosynthetic machinery. The unique chemical functionality of these analogs is exploited for selective attachment of singlet oxygen-generating fluorescent dyes via bioorthogonal 'click chemistry' ligations. Illumination of dye-labeled structures generates singlet oxygen to locally catalyze the polymerization of diaminobenzidine into an osmiophilic reaction product that is readily imaged by EM. We describe the application of click-EM in imaging metabolically tagged DNA, RNA and lipids in cultured cells and neurons and highlight its use in tracking peptidoglycan synthesis in the Gram-positive bacterium Listeria monocytogenes. PMID:27110681

  14. The Orthogonally Partitioned EM Algorithm: Extending the EM Algorithm for Algorithmic Stability and Bias Correction Due to Imperfect Data.

    PubMed

    Regier, Michael D; Moodie, Erica E M

    2016-05-01

    We propose an extension of the EM algorithm that exploits the common assumption of unique parameterization, corrects for biases due to missing data and measurement error, converges for the specified model when standard implementation of the EM algorithm has a low probability of convergence, and reduces a potentially complex algorithm into a sequence of smaller, simpler, self-contained EM algorithms. We use the theory surrounding the EM algorithm to derive the theoretical results of our proposal, showing that an optimal solution over the parameter space is obtained. A simulation study is used to explore the finite sample properties of the proposed extension when there is missing data and measurement error. We observe that partitioning the EM algorithm into simpler steps may provide better bias reduction in the estimation of model parameters. The ability to breakdown a complicated problem in to a series of simpler, more accessible problems will permit a broader implementation of the EM algorithm, permit the use of software packages that now implement and/or automate the EM algorithm, and make the EM algorithm more accessible to a wider and more general audience. PMID:27227718

  15. Evaluation of Fracture Azimuth by EM Wave and Elastic Wave

    NASA Astrophysics Data System (ADS)

    Feng, X.; Wang, Q.; Liu, C.; Lu, Q.; Zeng, Z.; Liang, W.; Yu, Y.; Ren, Q.

    2013-12-01

    Fracture system plays an important role in the development of underground energy, for example enhanced geothermal system (EGS), oil shale and shale gas, etc. Therefore, it becomes more and more important to detect and evaluate the fracture system. Geophysical prospecting is an useful method to evaluate the characteristics of the subsurface fractures. Currently, micro-seismology, multi-wave seismic exploration, and electromagnetic (EM) survey are reported to be used for the purpose. We are studying a method using both elastic wave and EM wave to detect and evaluate the fracture azimuth in laboratory. First, we build a 3D horizontal transverse isotropy (HTI) model, shown in the figure 1, by dry parallel fractures system, which was constructed by plexiglass plates and papers. Then, we used the ultrasonic system to obtain reflected S-wave data. Depending on the shear wave splitting, we evaluated the fracture azimuth by the algorithm of Pearson correlation coefficient. In addition, we used the full Polarimetric ultra wide band electromagnetic (FP-UWB-EM) wave System, shown in the figure 2, to obtain full polarimetric reflected EM-wave data. Depending on the rotation of the EM wave polarimetry, we evaluated the fracture azimuth by the the ration between maximum amplitude of co-polarimetric EM wave and maximum amplitude of cross-polarimetric EM wave. Finally, we used both EM-wave data and S-wave data to evaluate the fracture azimuth by the method of cross plot and statistical mathematics. To sum up, we found that FP-UWB-EM wave can be used to evaluated the fracture azimuth and is more accurate than ultrasound wave. Also joint evaluation using both data could improve the precision.

  16. Refinement of atomic models in high resolution EM reconstructions using Flex-EM and local assessment

    PubMed Central

    Joseph, Agnel Praveen; Malhotra, Sony; Burnley, Tom; Wood, Chris; Clare, Daniel K.; Winn, Martyn; Topf, Maya

    2016-01-01

    As the resolutions of Three Dimensional Electron Microscopic reconstructions of biological macromolecules are being improved, there is a need for better fitting and refinement methods at high resolutions and robust approaches for model assessment. Flex-EM/MODELLER has been used for flexible fitting of atomic models in intermediate-to-low resolution density maps of different biological systems. Here, we demonstrate the suitability of the method to successfully refine structures at higher resolutions (2.5–4.5 Å) using both simulated and experimental data, including a newly processed map of Apo-GroEL. A hierarchical refinement protocol was adopted where the rigid body definitions are relaxed and atom displacement steps are reduced progressively at successive stages of refinement. For the assessment of local fit, we used the SMOC (segment-based Manders’ overlap coefficient) score, while the model quality was checked using the Qmean score. Comparison of SMOC profiles at different stages of refinement helped in detecting regions that are poorly fitted. We also show how initial model errors can have significant impact on the goodness-of-fit. Finally, we discuss the implementation of Flex-EM in the CCP-EM software suite. PMID:26988127

  17. Refinement of atomic models in high resolution EM reconstructions using Flex-EM and local assessment.

    PubMed

    Joseph, Agnel Praveen; Malhotra, Sony; Burnley, Tom; Wood, Chris; Clare, Daniel K; Winn, Martyn; Topf, Maya

    2016-05-01

    As the resolutions of Three Dimensional Electron Microscopic reconstructions of biological macromolecules are being improved, there is a need for better fitting and refinement methods at high resolutions and robust approaches for model assessment. Flex-EM/MODELLER has been used for flexible fitting of atomic models in intermediate-to-low resolution density maps of different biological systems. Here, we demonstrate the suitability of the method to successfully refine structures at higher resolutions (2.5-4.5Å) using both simulated and experimental data, including a newly processed map of Apo-GroEL. A hierarchical refinement protocol was adopted where the rigid body definitions are relaxed and atom displacement steps are reduced progressively at successive stages of refinement. For the assessment of local fit, we used the SMOC (segment-based Manders' overlap coefficient) score, while the model quality was checked using the Qmean score. Comparison of SMOC profiles at different stages of refinement helped in detecting regions that are poorly fitted. We also show how initial model errors can have significant impact on the goodness-of-fit. Finally, we discuss the implementation of Flex-EM in the CCP-EM software suite. PMID:26988127

  18. Environmental Education and Development Division (EM-522). Annual report, Fiscal year 1993

    SciTech Connect

    Not Available

    1993-12-31

    The Environmental Education and Development Division (EM-522) is one of three divisions within the Office of Technology Integration and Environmental Education and Development (EM-52) in Environmental Restoration and Waste Management`s (EM`s) Office of Technology Development (EM-50). The primary design criterion for EM-522 education activities is directly related to meeting EM`s goal of environmental compliance on an accelerated basis and cleanup of the 1989 inventory of inactive sites and facilities by the year 2019. Therefore, EM-522`s efforts are directed specifically toward stimulating knowledge and capabilities to achieve the goals of EM while contributing to DOE`s overall goal of increasing scientific, mathematical, and technical literacy and competency. This report discusses fiscal year 1993 activities.

  19. Electromagnetic optimization of EMS-MAGLEV systems

    SciTech Connect

    Andriollo, M.; Martinelli, G.; Morini, A.; Tortella, A.

    1998-07-01

    In EMS-MAGLEV high-speed transport systems, devices for propulsion, levitation and contactless on-board electric power transfer are combined in a single electromagnetic structure. The strong coupling among the windings affects the performance of each device and requires the utilization of numerical codes. The paper describes an overall optimization procedure, based on a suitable mathematical model of the system, which takes into account several items of the system performance. The parameters of the model are calculated by an automated sequence of FEM analyses of the configuration. Both the linear generator output characteristics and the propulsion force ripple are improved applying the procedure to a reference configuration. The results are compared with the results obtained by a sequence of partial optimizations operating separately on two different subsets of the geometric parameters.

  20. DOE EM industry programs robotics development

    SciTech Connect

    Staubly, R.; Kothari, V.

    1997-12-01

    The Office of Science and Technology (OST) manages an aggressive program for RD&D, as well as testing and evaluation for the U.S. Department of Energy`s (DOE) Environmental Management (EM) organization. The goal is to develop new and improved environmental restoration and waste management technologies to clean up the inventory of the DOE weapons complex faster, safer, and cheaper than is possible with currently available technologies. OST has organized technology management activities along focus teams for each major problem area. There are currently five focus areas: decontamination and decommissioning, tanks, subsurface contaminants, mixed waste, and plutonium. In addition, OST is pursuing research and development (R&D) that cuts across these focus areas by having applications in two or more focus areas. Currently, there are three cross-cutting programs: the robotics technology development; characterization, monitoring, and sensor technologies; and efficient separations and processing.

  1. Online EM with weight-based forgetting.

    PubMed

    Celaya, Enric; Agostini, Alejandro

    2015-05-01

    In the online version of the EM algorithm introduced by Sato and Ishii ( 2000 ), a time-dependent discount factor is introduced for forgetting the effect of the old estimated values obtained with an earlier, inaccurate estimator. In their approach, forgetting is uniformly applied to the estimators of each mixture component depending exclusively on time, irrespective of the weight attributed to each unit for the observed sample. This causes an excessive forgetting in the less frequently sampled regions. To address this problem, we propose a modification of the algorithm that involves a weight-dependent forgetting, different for each mixture component, in which old observations are forgotten according to the actual weight of the new samples used to replace older values. A comparison of the time-dependent versus the weight-dependent approach shows that the latter improves the accuracy of the approximation and exhibits much greater stability. PMID:25710091

  2. Processing of Structurally Heterogeneous Cryo-EM Data in RELION.

    PubMed

    Scheres, S H W

    2016-01-01

    This chapter describes algorithmic advances in the RELION software, and how these are used in high-resolution cryo-electron microscopy (cryo-EM) structure determination. Since the presence of projections of different three-dimensional structures in the dataset probably represents the biggest challenge in cryo-EM data processing, special emphasis is placed on how to deal with structurally heterogeneous datasets. As such, this chapter aims to be of practical help to those who wish to use RELION in their cryo-EM structure determination efforts. PMID:27572726

  3. Comment on ``Geoeffectiveness of Halo Coronal Mass Ejections'' by N. Gopalswamy, S. Yashiro, and S. Akiyama (J. Geophys. Res. 2007, 112, doi:10.1029/2006JA012149)

    NASA Astrophysics Data System (ADS)

    Yermolaev, Yu. I.

    2008-12-01

    Comment on paper: Gopalswamy, N., S. Yashiro, and S. Akiyama (2007), Geoeffectiveness of halo coronal mass ejections, J. Geophys. Res., 112, A06112, doi:10.1029/2006JA012149 Gopalswamy et al. [2007] studied the geoeffectiveness of halo coronal mass ejections (CMEs) on the basis of solar observations during 1996-2005 and found that the geoeffectiveness of 229 frontside halo CMEs was 71%. Recently for observations of 305 frontside halo CMEs during 1997-2003 the geoeffectiveness was found to be 40% [Kim et al., 2005]. Complex analysis of both solar and interplanetary measurements showed that the geoeffectiveness of frontside halo CMEs is likely to be about 50% [Yermolaev et al., 2005; Yermolaev and Yermolaev, 2006]. Gopalswamy et al. [2007] did not discuss possible causes of this difference and were limited only to the general words: "The reason for the conflicting results (geoeffectiveness of CMEs ranging from 35% to more than 80%) may be attributed to the different definition of halo CMEs and geoeffectiveness." So, here we shall present our point of view on high geoeffectivenees of CME obtained in paper by Gopalswamy et al. [2007].

  4. Observation of the {nu}{sub 1} OH(OD) stretch of HOI and DOI by Fourier transform infrared emission spectroscopy

    SciTech Connect

    Klaassen, J.J.; Lindner, J.; Leone, S.R. |

    1996-05-01

    The spectra of vibrationally hot HOI formed in the reaction of alkyl iodides with oxygen atoms are observed by Fourier transform infrared emission spectroscopy. The {ital v}=1{endash}3 levels of the OH stretch are observed via the {Delta}{ital v}={minus}1 and {Delta}{ital v}={minus}2 sequence bands. The spectrum of DOI is observed by using 2,2,2-{ital d}{sub 3}-iodoethane as the precursor in the oxygen atom reaction. The {ital v}=1{endash}4 levels of the OD stretch are observed in the {Delta}{ital v}={minus}1 sequence band, and the {ital v}=1{endash}5 levels of the OD stretch are observed in {Delta}{ital v}={minus}2. Medium resolution spectra (0.031 cm{sup {minus}1} apodized) are recorded and rotationally analyzed for the {nu}{sub 1} fundamental and 2{nu}{sub 1}{minus}{nu}{sub 1} hot band of HOI. An estimate of the HOI ground state structure is made by constraining the OH bond length to its value for HOCl and HOBr and calculating the HOI bond angle and the OI bond length by least squares fit to the ground state rotational constants. {copyright} {ital 1996 American Institute of Physics.}

  5. DOI/GTN-P climate and active-layer data acquired in the National Petroleum Reserve: Alaska and the Arctic National Wildlife Refuge, 1998-2011

    USGS Publications Warehouse

    Urban, Frank E.; Clow, Gary D.

    2014-01-01

    This report provides data collected by the climate monitoring array of the U.S. Department of the Interior on Federal lands in Arctic Alaska over the period August 1998 to July 2011; this array is part of the Global Terrestrial Network for Permafrost, (DOI/GTN-P). In addition to presenting data, this report also describes monitoring, data collection, and quality-control methodology. This array of 16 monitoring stations spans lat 68.5°N. to 70.5°N. and long 142.5°W. to 161°W., an area of approximately 150,000 square kilometers. Climate summaries are presented along with quality-controlled data. Data collection is ongoing and includes the following climate- and permafrost-related variables: air temperature, wind speed and direction, ground temperature and soil moisture, snow depth, rainfall, up- and downwelling shortwave radiation, and atmospheric pressure. These data were collected by the U.S. Geological Survey in close collaboration with the Bureau of Land Management and the U.S. Fish and Wildlife Service.

  6. DOI/GTN-P Climate and active-layer data acquired in the National Petroleum Reserve–Alaska and the Arctic National Wildlife Refuge, 1998–2014

    USGS Publications Warehouse

    Urban, Frank E.; Clow, Gary D.

    2016-01-01

    This report provides data collected by the climate monitoring array of the U.S. Department of the Interior on Federal lands in Arctic Alaska over the period August 1998 to July 2014; this array is part of the Global Terrestrial Network for Permafrost (DOI/GTN-P). In addition to presenting data, this report also describes monitoring, data collection, and quality-control methods. The array of 16 monitoring stations spans lat 68.5°N. to 70.5°N. and long 142.5°W. to 161°W., an area of approximately 150,000 square kilometers. Climate summaries are presented along with quality-controlled data. Data collection is ongoing and includes the following climate- and permafrost-related variables: air temperature, wind speed and direction, ground temperature, soil moisture, snow depth, rainfall totals, up- and downwelling shortwave radiation, and atmospheric pressure. These data were collected by the U.S. Geological Survey in close collaboration with the Bureau of Land Management and the U.S. Fish and Wildlife Service.

  7. DOI/GTN-P climate and active-layer data acquired in the National Petroleum Reserve-Alaska and the Arctic National Wildlife Refuge

    USGS Publications Warehouse

    Urban, Frank E.; Clow, Gary D.

    2014-01-01

    This report provides data collected by the climate monitoring array of the U.S. Department of the Interior on Federal lands in Arctic Alaska over the period August 1998 to July 2013; this array is part of the Global Terrestrial Network for Permafrost, (DOI/GTN-P). In addition to presenting data, this report also describes monitoring, data collection, and quality-control methods. This array of 16 monitoring stations spans lat 68.5°N. to 70.5°N. and long 142.5°W. to 161°W., an area of approximately 150,000 square kilometers. Climate summaries are presented along with quality-controlled data. Data collection is ongoing and includes the following climate- and permafrost-related variables: air temperature, wind speed and direction, ground temperature, soil moisture, snow depth, rainfall totals, up- and downwelling shortwave radiation, and atmospheric pressure. These data were collected by the U.S. Geological Survey in close collaboration with the Bureau of Land Management and the U.S. Fish and Wildlife Service.

  8. Test beam performance of CDF plug upgrade EM calorimeter

    SciTech Connect

    Fukui, Y.

    1998-11-01

    CDF Plug Upgrade(tile-fiber) EM Calorimeter performed resolution of 15{percent}/{radical} (E) {circle_plus}0.7{percent} with non-linearity less than 1{percent} in a energy range of 5{endash}180 GeV at Fermilab Test Beam. Transverse uniformity of inside-tower-response of the EM Calorimeter was 2.2{percent} with 56 GeV positron, which was reduced to 1.0{percent} with response map correction. We observed 300 photo electron/GeV in the EM Calorimeter. Ratios of EM Calorimeter response to positron beam to that to {sup 137}C{sub s} Source was stable within 1{percent} in the period of 8 months. {copyright} {ital 1998 American Institute of Physics.}

  9. E.M. and Hadronic Shower Simulation with FLUKA

    SciTech Connect

    Battistoni, G.; Fasso, A.; Ferrari, A.; Ranft, J.; Rubbia, A.; Sala, P.R.; /INFN, Milan /SLAC /CERN /Siegen U. /Zurich, ETH

    2005-10-03

    A description of the main features of e.m. and hadronic shower simulation models used in the FLUKA code is summarized and some recent applications are discussed. The general status of the FLUKA project is also reported.

  10. 7 CFR 759.6 - EM to be made available.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... Agriculture under the Plant Protection Act or the animal quarantine laws, as defined in section 2509 of the Food, Agriculture, Conservation, and Trade Act of 1990, automatically authorizes EM for production...

  11. 7 CFR 759.6 - EM to be made available.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... Agriculture under the Plant Protection Act or the animal quarantine laws, as defined in section 2509 of the Food, Agriculture, Conservation, and Trade Act of 1990, automatically authorizes EM for production...

  12. NASA EM Followup of LIGO-Virgo Candidate Events

    NASA Technical Reports Server (NTRS)

    Blackburn, Lindy L.

    2011-01-01

    We present a strategy for a follow-up of LIGO-Virgo candidate events using offline survey data from several NASA high-energy photon instruments aboard RXTE, Swift, and Fermi. Time and sky-location information provided by the GW trigger allows for a targeted search for prompt and afterglow EM signals. In doing so, we expect to be sensitive to signals which are too weak to be publicly reported as astrophysical EM events.

  13. EM Telemetry Tool for Deep Well Drilling Applications

    SciTech Connect

    Jeffrey M. Gabelmann

    2005-11-15

    This final report discusses the successful development and testing of a deep operational electromagnetic (EM) telemetry system, produced under a cooperative agreement with the United States Department of Energy's National Energy Technology Laboratory. This new electromagnetic telemetry system provides a wireless communication link between sensors deployed deep within oil and gas wells and data acquisition equipment located on the earth's surface. EM based wireless telemetry is a highly appropriate technology for oil and gas exploration in that it avoids the need for thousands of feet of wired connections. In order to achieve the project performance objectives, significant improvements over existing EM telemetry systems were made. These improvements included the development of new technologies that have improved the reliability of the communications link while extending operational depth. A key element of the new design is the incorporation of a data-fusion methodology which enhances the communication receiver's ability to extract very weak signals from large amounts of ambient environmental noise. This innovative data-fusion receiver based system adapts advanced technologies, not normally associated with low-frequency communications, and makes them work within the harsh drilling environments associated with the energy exploration market. Every element of a traditional EM telemetry system design, from power efficiency to reliability, has been addressed. The data fusion based EM telemetry system developed during this project is anticipated to provide an EM tool capability that will impact both onshore and offshore oil and gas exploration operations, for conventional and underbalanced drilling applications.

  14. Seasonal biodiversity of black flies (Diptera: Simuliidae) and evaluation of ecological factors influencing species distribution at Doi Pha Hom Pok National Park, Thailand.

    PubMed

    Srisuka, Wichai; Takaoka, Hiroyuki; Otsuka, Yasushi; Fukuda, Masako; Thongsahuan, Sorawat; Taai, Kritsana; Choochote, Wej; Saeung, Atiporn

    2015-09-01

    This is the first study on the seasonal biodiversity of black flies and evaluation of ecological factors influencing their distribution at Doi Pha Hom Pok National Park, northern Thailand. Larvae were collected from six fixed-stream sites in relation to altitude gradients from May 2011 to April 2013. The water temperature, water pH, conductivity, total dissolved solids (TDS), salt, water velocity, stream width and depth, streambed particle sizes, riparian vegetation, and canopy cover were recorded from each site. Monthly collections from the six sites yielded 5475 last-instar larvae, belonging to 29 black fly species. The most frequently found species from all sites were Simulium asakoae (100%) followed by Simulium yuphae (83.3%), and Simulium chiangdaoense, Simulium gombakense, Simulium phahompokense, Simulium fruticosum, Simulium maeaiense and Simulium fenestratum (66.6%). Of the 5475 last-instar larvae, S. maeaiense (19.3%), S. chiangdaoense (15.8%) and S. asakoae (14.8%), were the three most abundant species. The Shannon diversity index (H) at the six sites with different altitudes of 2100m, 2000m, 1500m, 1400m, 700m, and 500m above mean sea level, were 2.042, 1.832, 2.158, 2.123, 1.821 and 1.822, respectively. The Shannon index and number of taxa in the cold season were higher than those in the rainy and hot seasons. Principal component analysis (PCA) indicated that at least three principal components have eigen values >1.0 and accounted for 93.5% of the total variability of ecological factors among sampling sites. The Canonical correspondence analyses (CCA) showed that most species had a trend towards altitude, canopy cover, riparian vegetation and water velocity. PMID:26028177

  15. A HF EM installation allowing simultaneous whole body and deep local EM hyperthermia.

    PubMed

    Mazokhin, V N; Kolmakov, D N; Lucheyov, N A; Gelvich, E A; Troshin, I I

    1999-01-01

    The structure and main features of a HF EM installation based upon a new approach for creating electromagnetic fields destined for whole body (WBH) and deep local (DLH) hyperthermia are discussed. The HF EM field, at a frequency of 13.56 MHz, is created by a coplanar capacity type applicator positioned under a distilled water filled bolus that the patient is lying on. The EM energy being released directly in the deep tissues ensures effective whole body heating to required therapeutic temperatures of up to 43.5 degrees C, whereas the skin temperature can be maintained as low as 39-40.5 degrees C. For DLH, the installation is equipped with additional applicators and a generator operating at a frequency of 40.68 MHz. High efficiency of the WBH applicator makes it possible to carry out the WBH procedure without any air-conditioning cabin. Due to this, a free access to the patient's body during the WBH treatment is provided and a simultaneous WBH/DLH or WBH/LH procedure by means of additional applicators is possible. Controllable power output in the range of 100-800 W at a frequency of 13.56 MHz and 50-350 W at a frequency of 40.68 MHz allows accurate temperature control during WBH, DLH and WBH/DLH procedures. SAR patterns created by the WBH and DLH applicators in a liquid muscle phantom and measured by means of a non-perturbing E-dipole are investigated. The scattered EM field strength measured in the vicinity of the operating installation during the WBH, DLH and WBH/DLH procedures does not exceed security standards. Examples of temperature versus time graphs in the course of WBH, DLH and WBH/DLH procedures in clinics are presented. The installation is successfully used in leading oncological institutions of Russia and Belarus, though combined WBH/DLH procedures are evidently more complicated and demand thorough planning and temperature measurements to avoid overheating. PMID:10458570

  16. Analysis of EM dataset with several sensor configurations obtained by the loop-loop EM survey on magnetic anomalies

    NASA Astrophysics Data System (ADS)

    CHOI, J.; Yi, M. J.; Sasaki, Y.; Son, J.; Nam, M. J.

    2015-12-01

    Most of mineral mines in Korea are located in rugged mountain area embedding small-scale anomalies. Loop-loop EM survey system can be a better choice for exploring those mines because no ground contact is required and portable loops are freely positioned. Survey design is very important for detecting small amount of mineral deposits efficiently and spatial limits of survey lines should be considered. Along a same survey line, surveys with different separations between a transmitter and a receiver are applicable. EM responses are calculated in a layered-earth model embedding magnetic anomalies and analyses considering electric conductivity and magnetic permeability are made for the loop-loop EM survey data. Combining EM dataset with multi-frequency and multi-separation slightly enhanced a reconstructed image. Loop-loop EM survey using PROMOIS system was conducted on a small magnetite mine. Inversion with and without considering magnetic permeability was conducted for EM data with multi-frequency and multi-separation between a transmitter and a receiver.

  17. DOE EM industry programs robotics development

    SciTech Connect

    Staubly, R.; Kothari, V.

    1998-12-31

    The Office of Science and Technology (OST) manages an aggressive program for RD and D, as well as testing and evaluation for the Department of Energy`s (DOE`s) Environmental Management (EM) organization. The goal is to develop new and improved environmental restoration and waste management technologies to clean up the inventory of the DOE weapons complex faster, safer, and cheaper than is possible with currently available technologies. Robotic systems reduce worker exposure to the absolute minimum, while providing proven, cost-effective, and, for some applications, the only acceptable technique for addressing challenging problems. Development of robotic systems for remote operations occurs in three main categories: tank waste characterization and retrieval; decontamination and dismantlement; and characterization, mapping, and inspection systems. In addition, the Federal Energy Technology Center (FETC) has some other projects which fall under the heading of supporting R and D. The central objective of all FETC robotic projects is to make robotic systems more attractive by reducing costs and health risks associated with the deployment of robotic technologies in the cleanup of the nuclear weapons complex. This will be accomplished through development of robots that are cheaper, faster, safer, and more reliable, as well as more straightforward to modify/adapt and more intuitive to operate with autonomous capabilities and intelligent controls that prevent accidents and optimize task execution.

  18. Databases and Archiving for CryoEM.

    PubMed

    Patwardhan, A; Lawson, C L

    2016-01-01

    CryoEM in structural biology is currently served by three public archives-EMDB for 3DEM reconstructions, PDB for models built from 3DEM reconstructions, and EMPIAR for the raw 2D image data used to obtain the 3DEM reconstructions. These archives play a vital role for both the structural community and the wider biological community in making the data accessible so that results may be reused, reassessed, and integrated with other structural and bioinformatics resources. The important role of the archives is underpinned by the fact that many journals mandate the deposition of data to PDB and EMDB on publication. The field is currently undergoing transformative changes where on the one hand high-resolution structures are becoming a routine occurrence while on the other hand electron tomography is enabling the study of macromolecules in the cellular context. Concomitantly the archives are evolving to best serve their stakeholder communities. In this chapter, we describe the current state of the archives, resources available for depositing, accessing, searching, visualizing and validating data, on-going community-wide initiatives and opportunities, and challenges for the future. PMID:27572735

  19. Degradation of Benzodiazepines after 120 Days of EMS Deployment

    PubMed Central

    McMullan, Jason T.; Jones, Elizabeth; Barnhart, Bruce; Denninghoff, Kurt; Spaite, Daniel; Zaleski, Erin; Silbergleit, Robert

    2014-01-01

    Introduction EMS treatment of status epilepticus improves outcomes, but the benzodiazepine best suited for EMS use is unclear, given potential high environmental temperature exposures. Objective To describe the degradation of diazepam, lorazepam, and midazolam as a function of temperature exposure and time over 120 days of storage on active EMS units. Methods Study boxes containing vials of diazepam, lorazepam, and midazolam were distributed to 4 active EMS units in each of 2 EMS systems in the southwestern United States during May–August 2011. The boxes logged temperature every minute and were stored in EMS units per local agency policy. Two vials of each drug were removed from each box at 30-day intervals and underwent high-performance liquid chromatography to determine drug concentration. Concentration was analyzed as mean (and 95%CI) percent of initial labeled concentration as a function of time and mean kinetic temperature (MKT). Results 192 samples were collected (2 samples of each drug from each of 4 units per city at 4 time-points). After 120 days, the mean relative concentration (95%CI) of diazepam was 97.0% (95.7–98.2%) and of midazolam was 99.0% (97.7–100.2%). Lorazepam experienced modest degradation by 60 days (95.6% [91.6–99.5%]) and substantial degradation at 90 days (90.3% [85.2-95.4%]) and 120 days (86.5% [80.7–92.3%]). Mean MKT was 31.6°C (95%CI 27.1–36.1). Increasing MKT was associated with greater degradation of lorazepam, but not midazolam or diazepam. Conclusions Midazolam and diazepam experienced minimal degradation throughout 120 days of EMS deployment in high-heat environments. Lorazepam experienced significant degradation over 120 days and appeared especially sensitive to higher MKT exposure. PMID:24548058

  20. Emergency medical service (EMS): A unique flight environment

    NASA Technical Reports Server (NTRS)

    Shively, R. Jay

    1993-01-01

    The EMS flight environment is unique in today's aviation. The pilots must respond quickly to emergency events and often fly to landing zones where they have never been before . The time from initially receiving a call to being airborne can be as little as two to three minutes. Often the EMS pilot is the only aviation professional on site, they have no operations people or other pilots to aid them in making decisons. Further, since they are often flying to accident scenes, not airports, there is often complete weather and condition information. Therefore, the initial decision that the pilot must make, accepting or declining a flight, can become very difficult. The accident rate of EMS helicopters has been relatively high over the past years. NASA-Ames research center has taken several steps in an attempt to aid EMS pilots in their decision making and situational awareness. A preflight risk assessment system (SAFE) was developed to aid pilots in their decision making, and was tested at an EMS service. The resutls of the study were promising and a second version incorporating the lessons learned is under development. A second line of research was the development of a low cost electronic chart display (ECD). This is a digital map display to help pilots maintain geographical orientation. Another thrust was undertaken in conjunction with the Aviation Safety Reporting System (ASRS). This involved publicizing the ASRS to EMS pilots and personnel, and calling each of the reporters back to gather additional information. This paper will discuss these efforts and how they may positively impact the safety of EMS operations.

  1. Persistent topology for cryo-EM data analysis.

    PubMed

    Xia, Kelin; Wei, Guo-Wei

    2015-08-01

    In this work, we introduce persistent homology for the analysis of cryo-electron microscopy (cryo-EM) density maps. We identify the topological fingerprint or topological signature of noise, which is widespread in cryo-EM data. For low signal-to-noise ratio (SNR) volumetric data, intrinsic topological features of biomolecular structures are indistinguishable from noise. To remove noise, we employ geometric flows that are found to preserve the intrinsic topological fingerprints of cryo-EM structures and diminish the topological signature of noise. In particular, persistent homology enables us to visualize the gradual separation of the topological fingerprints of cryo-EM structures from those of noise during the denoising process, which gives rise to a practical procedure for prescribing a noise threshold to extract cryo-EM structure information from noise contaminated data after certain iterations of the geometric flow equation. To further demonstrate the utility of persistent homology for cryo-EM data analysis, we consider a microtubule intermediate structure Electron Microscopy Data (EMD 1129). Three helix models, an alpha-tubulin monomer model, an alpha-tubulin and beta-tubulin model, and an alpha-tubulin and beta-tubulin dimer model, are constructed to fit the cryo-EM data. The least square fitting leads to similarly high correlation coefficients, which indicates that structure determination via optimization is an ill-posed inverse problem. However, these models have dramatically different topological fingerprints. Especially, linkages or connectivities that discriminate one model from another, play little role in the traditional density fitting or optimization but are very sensitive and crucial to topological fingerprints. The intrinsic topological features of the microtubule data are identified after topological denoising. By a comparison of the topological fingerprints of the original data and those of three models, we found that the third model is

  2. Gradiente radial de [Mg/Fe] em duas galáxias elípticas

    NASA Astrophysics Data System (ADS)

    Milone, A.; Capelato, H.

    2003-08-01

    Basicamente, são propostos dois cenários de evolução quí mio-dinâmico para os sistemas esferoidais: (i) o hierárquico através da fusão e/ou acresção de sub-sistemas com ou sem surtos de formação estelar, e (ii) o colapso monolí tico dissipativo com formação estelar interrompida por um vento galáctico. Ambos, dentro de certos limites, conseguem explicar os gradientes internos de metalicidade estelar presentes nas galáxias elí pticas bem como a relação observada entre a metalicidade central e a massa (Mg20 vs. log sv0). No entanto, nenhum prevê uma variação interna para a razão de abundâncias Mg/Fe que indiretamente define a escala temporal da formação estelar. Empregamos a espectroscopia óptica de fenda longa com a finalidade de recuperar as histórias de formação estelar, de enriquecimento quí mico e da dinâmica dentro de determinadas regiões das galáxias. Os espectros de média resolução (FWHM = 7,1 Å) e escala angular de 1,092 arcsec/pixel foram coletados com o telescópio 1,60m do OPD/LNA. Comparamos nossas medidas de linhas de absorção com resultados espectrofotométricos de modelos de populações estelares simples - mais especificamente os í ndices do Sistema Lick como Mg2, Mg b, < Fe > e Hb - a fim de se investigar as variações internas de [Fe/H], [Mg/Fe] e idade. Para duas galáxias elí pticas, NGC 1052 e NGC 7796, pertencentes a ambientes de baixa densidade, encontramos uma variação radial da razão Mg/Fe decrescente do centro para fora em regiões de 0,6 e 1 raio efetivo respectivamente. Discutimos alguns cenários de enriquecimento quí mico para estas duas galáxias.

  3. Colloidal Oatmeal <em>(Avena Sativa)em> Improves Skin Barrier Through Multi-Therapy Activity.

    PubMed

    Ilnytska, Olha; Kaur, Simarna; Chon, Suhyoun; Reynertson, Kurt A; Nebus, Judith; Garay, Michelle; Mahmood, Khalid; Southall, Michael D

    2016-06-01

    Oats (Avena sativa) are a centuries-old topical treatment for a variety of skin barrier conditions, including dry skin, skin rashes, and eczema; however, few studies have investigated the actual mechanism of action for the skin barrier strengthening activity of colloidal oatmeal. Four extracts of colloidal oatmeal were prepared with various solvents and tested in vitro for skin barrier related gene expression and activity. Extracts of colloidal oatmeal were found to induce the expression of genes related to epidermal differentiation, tight junctions and lipid regulation in skin, and provide pH-buffering capacity. Colloidal oatmeal boosted the expression of multiple target genes related to skin barrier, and resulted in recovery of barrier damage in an in vitro model of atopic dermatitis. In addition, an investigator-blinded study was performed with 50 healthy female subjects who exhibited bilateral moderate to severe dry skin on their lower legs. Subjects were treated with a colloidal oatmeal skin protectant lotion. Clinically, the colloidal oatmeal lotion showed significant clinical improvements in skin dryness, moisturization, and barrier. Taken together, these results demonstrate that colloidal oatmeal can provide clinically effective benefits for dry and compromised skin by strengthening skin barrier.

    <em>J Drugs Dermatolem>. 2016;15(6):684-690. PMID:27272074

  4. Uma comparação entre técnicas de propagação de erros em astrofísica: Monte Carlo x Bootstrap

    NASA Astrophysics Data System (ADS)

    Waelkens, A. H.; Janot Pacheco, E.

    2003-08-01

    Recentemente Dhillon & Watson (2001) criticaram o procedimento de determinação de erros via simulações de Monte Carlo no caso do imageamento indireto de estrelas, por introduzir ruído nos dados e resultar em erros superestimados. Estes autores propuseram a utilização alternativa do método de Bootstrap como uma técnica superior para a estimativa de erros. Neste trabalho apresentamos os resultados de um estudo comparativo da performance das técnicas de simulação por Monte Carlo e por Bootstrap para a determinação de erros em duas situações de interesse: (i) ajuste de modelos a espectros observados e (ii) imageamento indireto de discos de acréscimo com técnicas de mapeamento por eclipse. No caso (i), os dados de entrada são espectros de emissão simples de hidrogênio aos quais é adicionado ruído gaussiano de amplitude selecionada. No caso (ii), são produzidas curvas de luz do eclipse de uma distribuição de brilho seguindo a lei TµR-3/4 para discos estacionários cuja taxa de acréscimo varia ao longo do eclipse segundo uma distribuição gaussiana de amplitude selecionada, simulando o ruído. A avaliação da performance é feita com o auxílio de um diagrama do erro relativo na grandeza ajustada, conforme obtido por cada método, versus o erro relativo (ruído/sinal) dos dados de entrada. O estudo mostra que as duas técnicas produzem resultados semelhantes nos dois casos, e que a suposta superioridade do método de Bootstrap não se confirma.

  5. Learning when to Hold'em and When to Fold'em: ERS's Budget Hold'em Game Facilitates the Budget Development Process in Memphis

    ERIC Educational Resources Information Center

    Education Resource Strategies, 2010

    2010-01-01

    If your school district is facing a budget issue, it might surprise you to learn that the solution might very well lie in a game of cards. That certainly was the case earlier this year for the city schools of Memphis, Tennessee. The game is called Budget Hold'em, and it was developed by Education Resource Strategies (ERS) of Watertown,…

  6. Topical Treatment With an Agent Disruptive to <em>P. acnesem> Biofilm Provides Positive Therapeutic Response: Results of a Randomized Clinical Trial.

    PubMed

    Bernhardt, Michael J; Myntti, Matthew F

    2016-06-01

    The traditional disease model of acne has been one of follicular plugging due to 'sticky epithelial cells' associated with increased sebum production with deep follicular anaerobic conditions favoring <em>P. acnesem>- generated inflammation. <em>P. acnesem> biofilms have been found more frequently in patients with acne than controls. Biofilms are genetically coded to create adhesion to the pilosebaceous unit followed by production of a mucopolysaccharide coating capable of binding to lipid surfaces. Traditional therapies for acne have involved mixtures of oral and topical antibiotics admixed with topical keratolytics and retinoids, which are aimed at traditional bacterial reduction as well as downregulating the inflammatory cascade. These approaches are limited by side effect and compliance/tolerability issues. As the <em>P. acnesem> biofilm may, in fact, be the instigator of this process, we studied the use of a topical agent designed to reduce the <em>P. acnesem> biofilm to see if reducing the biofilm would be therapeutically efficacious. We present data of a proprietary topical non-prescription agent with a novel pharmaco mechanism designed to attack the biofilm produced by <em>P. acnesem>. Our data shows a decrease of inflammatory lesions by 44% and non-inflammatory lesions by 32% after 12 weeks and also provided for a meaningful improvement in the quality of life of the patients in the study. These improvements were achieved with a product that was not associated with burning, chafing, irritation, or erythema, which can be seen with topical treatments. It is apparent from this study that by addressing the biofilm which protects the <em>P. acnesem> bacteria through the use of the Acne Gel, the incidence of acne symptoms can be greatly reduced, while having no negative impacts on the patients' skin (ClinicalTrials.gov registry number NCT02404285).

    <em>J Drugs Dermatol. em>2016;15(6):677-683. PMID:27272073

  7. Earth and Heavens: Two Separate Universes? (Spanish Title: Tierra y Cielos: ¿Dos Universos Separados?) Terra e Céus: Dois Universos Separados?

    NASA Astrophysics Data System (ADS)

    Carrascosa, Jaime; Gil-Pérez, Daniel; Solbes, Jordi; Vilches, Amparo

    2005-12-01

    The study of gravitation constitutes an exceptional occasion to show the richness and complexity of science and technology, contemplating, among other things: the problematic situations which are at the heart of the scientific knowledge, the difficulties encountered in the construction of knowledge and, especially, the necessity of overcoming "common-sense evidence" that proclaimed the existence of an insurmountable barrier between Earth and Heavens, hindering scientific development during many centuries. In this paper we present a program of activities to orient the study of Gravitation atUpperHigh School, favoring students' participation in the reconstruction of this first scientific revolution and giving them the opportunity to see the importance of Astronomy both in the history of science and today. El estudio de la gravitación constituye una ocasión excepcional para mostrar la ciencia y la tecnología en toda su riqueza y complejidad, considerando, entre otros aspectos:

  8. Las situaciones problemáticas relevantes que llevaron a la construcción de los conocimientos,
  9. las dificultades de todo tipo con las que hubo que enfrentarse y, muy en particular,
  10. la necesidad de superar las "evidencias de sentido común" que establecían una supuesta barrera infranqueable entre la Tierray los Cielos y que obstaculizaron durante siglos el desarrollo científico.
  11. En este trabajo presentamos un programa de actividades para el estudio de la gravitación en la secundaria superior, orientado a favorecer la participación de los estudiantes, en alguna medida, en la reconstrucción de este proceso que constituyó la denominada primera gran revolución científica y asomándonos al estudio de una de las ciencias más antiguas, la Astronomía, que hoy sigue despertando gran interés. O estudo da gravitação constitui uma ocasião excepcional para mostrar a ciência e a tecnologia em toda sua riqueza e

  12. Refinement of Atomic Structures Against cryo-EM Maps.

    PubMed

    Murshudov, G N

    2016-01-01

    This review describes some of the methods for atomic structure refinement (fitting) against medium/high-resolution single-particle cryo-EM reconstructed maps. Some of the tools developed for macromolecular X-ray crystal structure analysis, especially those encapsulating prior chemical and structural information can be transferred directly for fitting into cryo-EM maps. However, despite the similarities, there are significant differences between data produced by these two techniques; therefore, different likelihood functions linking the data and model must be used in cryo-EM and crystallographic refinement. Although tools described in this review are mostly designed for medium/high-resolution maps, if maps have sufficiently good quality, then these tools can also be used at moderately low resolution, as shown in one example. In addition, the use of several popular crystallographic methods is strongly discouraged in cryo-EM refinement, such as 2Fo-Fc maps, solvent flattening, and feature-enhanced maps (FEMs) for visualization and model (re)building. Two problems in the cryo-EM field are overclaiming resolution and severe map oversharpening. Both of these should be avoided; if data of higher resolution than the signal are used, then overfitting of model parameters into the noise is unavoidable, and if maps are oversharpened, then at least parts of the maps might become very noisy and ultimately uninterpretable. Both of these may result in suboptimal and even misleading atomic models. PMID:27572731

  13. Active geophysical monitoring of hydrocarbon reservoirs using EM methods

    NASA Astrophysics Data System (ADS)

    Gribenko, A.; Black, N.; Zhdanov, M. S.

    2008-12-01

    Marine controlled-source electromagnetic (MCSEM) technology has been successfully established as an effective tool for offshore hydrocarbon (HC) exploration. In this paper we consider another application of the MCSEM method for HC reservoir monitoring. We demonstrate that EM methods can be successfully used for the monitoring of producing wells in connection with the enhanced recovery of hydrocarbons. We have developed a new powerful EM modeling technique based on the integral equation method with an inhomogeneous background conductivity (IE IBC). This new method and the corresponding computer software make it possible to model the EM response over a realistic complex model of a sea-bottom HC reservoir. The numerical modeling results demonstrate that the MCSEM method has the ability to map changes in resistivity caused by the production of hydrocarbons over time. In addition, the EM data help to visualize the changes in the location of the oil-water contact within the reservoir. This result opens the possibility for practical application of the EM method in HC reservoir monitoring.

  14. Application of the EM algorithm to radiographic images.

    PubMed

    Brailean, J C; Little, D; Giger, M L; Chen, C T; Sullivan, B J

    1992-01-01

    The expectation maximization (EM) algorithm has received considerable attention in the area of positron emitted tomography (PET) as a restoration and reconstruction technique. In this paper, the restoration capabilities of the EM algorithm when applied to radiographic images is investigated. This application does not involve reconstruction. The performance of the EM algorithm is quantitatively evaluated using a "perceived" signal-to-noise ratio (SNR) as the image quality metric. This perceived SNR is based on statistical decision theory and includes both the observer's visual response function and a noise component internal to the eye-brain system. For a variety of processing parameters, the relative SNR (ratio of the processed SNR to the original SNR) is calculated and used as a metric to compare quantitatively the effects of the EM algorithm with two other image enhancement techniques: global contrast enhancement (windowing) and unsharp mask filtering. The results suggest that the EM algorithm's performance is superior when compared to unsharp mask filtering and global contrast enhancement for radiographic images which contain objects smaller than 4 mm. PMID:1435595

  15. Breaking Cryo-EM Resolution Barriers to Facilitate Drug Discovery.

    PubMed

    Merk, Alan; Bartesaghi, Alberto; Banerjee, Soojay; Falconieri, Veronica; Rao, Prashant; Davis, Mindy I; Pragani, Rajan; Boxer, Matthew B; Earl, Lesley A; Milne, Jacqueline L S; Subramaniam, Sriram

    2016-06-16

    Recent advances in single-particle cryoelecton microscopy (cryo-EM) are enabling generation of numerous near-atomic resolution structures for well-ordered protein complexes with sizes ≥ ∼200 kDa. Whether cryo-EM methods are equally useful for high-resolution structural analysis of smaller, dynamic protein complexes such as those involved in cellular metabolism remains an important question. Here, we present 3.8 Å resolution cryo-EM structures of the cancer target isocitrate dehydrogenase (93 kDa) and identify the nature of conformational changes induced by binding of the allosteric small-molecule inhibitor ML309. We also report 2.8-Å- and 1.8-Å-resolution structures of lactate dehydrogenase (145 kDa) and glutamate dehydrogenase (334 kDa), respectively. With these results, two perceived barriers in single-particle cryo-EM are overcome: (1) crossing 2 Å resolution and (2) obtaining structures of proteins with sizes < 100 kDa, demonstrating that cryo-EM can be used to investigate a broad spectrum of drug-target interactions and dynamic conformational states. PMID:27238019

  16. International Space Station (ISS) Emergency Mask (EM) Development

    NASA Technical Reports Server (NTRS)

    Toon, Katherine P.; Hahn, Jeffrey; Fowler, Michael; Young, Kevin

    2011-01-01

    The Emergency Mask (EM) is considered a secondary response emergency Personal Protective Equipment (PPE) designed to provide respiratory protection to the International Space Station (ISS) crewmembers in response to a post-fire event or ammonia leak. The EM is planned to be delivered to ISS in 2012 to replace the current air purifying respirator (APR) onboard ISS called the Ammonia Respirator (AR). The EM is a one ]size ]fits ]all model designed to fit any size crewmember, unlike the APR on ISS, and uses either two Fire Cartridges (FCs) or two Commercial Off-the-Shelf (COTS) 3M(Trademark). Ammonia Cartridges (ACs) to provide the crew with a minimum of 8 hours of respiratory protection with appropriate cartridge swap ]out. The EM is designed for a single exposure event, for either post ]fire or ammonia, and is a passive device that cannot help crewmembers who cannot breathe on their own. The EM fs primary and only seal is around the wearer fs neck to prevent a crewmember from inhaling contaminants. During the development of the ISS Emergency Mask, several design challenges were faced that focused around manufacturing a leak free mask. The description of those challenges are broadly discussed but focuses on one key design challenge area: bonding EPDM gasket material to Gore(Registered Trademark) fabric hood.

  17. A Computerized Evaluation Methodology for Pre-Hospital EMS Cardiac Care

    PubMed Central

    Nagurney, Frank K.

    1980-01-01

    The computerized application of cardiac care protocols for pre-hospital EMS care is presented. The program logic is reviewed and an example of its application is provided. Uses of the results of the program in EMS management are suggested.

  18. EMS Stretcher “Misadventures” in a Large, Urban EMS System: A Descriptive Analysis of Contributing Factors and Resultant Injuries

    PubMed Central

    Goodloe, Jeffrey M.; Crowder, Christopher J.; Arthur, Annette O.; Thomas, Stephen H.

    2012-01-01

    Purpose. There is a paucity of data regarding EMS stretcher-operation-related injuries. This study describes and analyzes characteristics associated with undesirable stretcher operations, with or without resultant injury in a large, urban EMS agency. Methods. In the study agency, all stretcher-related “misadventures” are required to be documented, regardless of whether injury results. All stretcher-related reports between July 1, 2009 and June 30, 2010 were queried in retrospective analysis, avoiding Hawthorne effect in stretcher operations. Results. During the year studied, 129,110 patients were transported. 23 stretcher incidents were reported (0.16 per 1,000 transports). No patient injury occurred. Four EMS providers sustained minor injuries. Among contributing aspects, the most common involved operations surrounding the stretcher-ambulance safety latch, 14/23 (60.9%). From a personnel injury prevention perspective, there exists a significant relationship between combative patients and crew injury related to stretcher operation, Fisher's exact test 0.048. Conclusions. In this large, urban EMS system, the incidence of injury related to stretcher operations in the one-year study period is markedly low, with few personnel injuries and no patient injuries incurred. Safety for EMS personnel and patients could be advanced by educational initiatives that highlight specific events and conditions contributing to stretcher-related adverse events. PMID:22606379

  19. Recent technical advancements enabled atomic resolution CryoEM

    NASA Astrophysics Data System (ADS)

    Xueming, Li

    2016-01-01

    With recent breakthroughs in camera and image processing technologies single-particle electron cryo-microscopy (CryoEM) has suddenly gained the attention of structural biologists as a powerful tool able to solve the atomic structures of biological complexes and assemblies. Compared with x-ray crystallography, CryoEM can be applied to partially flexible structures in solution and without the necessity of crystallization, which is especially important for large complexes and assemblies. This review briefly explains several key bottlenecks for atomic resolution CryoEM, and describes the corresponding solutions for these bottlenecks based on the recent technical advancements. The review also aims to provide an overview about the technical differences between its applications in biology and those in material science. Project supported by Tsinghua-Peking Joint Center for Life Sciences, China.

  20. Virus particle dynamics derived from CryoEM studies.

    PubMed

    Doerschuk, Peter C; Gong, Yunye; Xu, Nan; Domitrovic, Tatiana; Johnson, John E

    2016-06-01

    The direct electron detector has revolutionized electron cryo-microscopy (CryoEM). Icosahedral virus structures are routinely produced at 4Å resolution or better and the approach has largely displaced virus crystallography, as it requires less material, less purity and often produces a structure more rapidly. Largely ignored in this new era of CryoEM is the dynamic information in the data sets that was not available in X-ray structures. Here we review an approach that captures the dynamic character of viruses displayed in the CryoEM ensemble of particles at the moment of freezing. We illustrate the approach with a simple model, briefly describe the details and provide a practical application to virus particle maturation. PMID:27085980

  21. Evolução temporal da explosão solar de 06 de junho de 2000 apresentando estruturas finas em rádio freqüências

    NASA Astrophysics Data System (ADS)

    Fernandes, F. C. R.; Sawant, H. S.; Cecatto, J. R.; Caracini, A. G.; Vats, H. O.; Karlický, M.; Meszarosova, H.

    2003-08-01

    Em 06 de junho de 2000 (~15: 00-17: 00 UT), o Brazilian Solar Spectroscope (BSS) registrou uma explosão solar intensa no intervalo de freqüência de (1000-2000) MHz, com alta resolução temporal (100 ms) e espectral (5 MHz). A atividade solar relacionada a esta explosão associada à região ativa (AR) 9026 e classificada como X2.3 foi grande. O Ondrejov Observatory registrou rádio emissões até 4,5 GHz. O satélite SOHO registrou uma série de erupções solares, incluindo uma Ejeção de Massa Coronal (CME) tipo "full-halo" (~15: 54 UT). Explosões tipo II/IV também foram registradas. Na faixa de ondas decimétricas, este evento apresentou dois picos distintos (~15: 21 UT e ~16: 42 UT). O primeiro pico coincide com a explosão registrada em raios-X moles (GOES) e em raios-X duros (Yohkoh). Os espectros dinâmicos com alta resolução do BSS revelaram várias estruturas finas, principalmente emissões tipo "zebra" e "fibra", rádio pulsações, emissões tipo III e do único caso de emissões "zebra" harmônicas observado na faixa decimétrica. Neste trabalho, analisamos a evolução temporal e o comportamento global do evento de 06 de junho de 2000, com ênfase na identificação e associação da ocorrência de cada tipo de estrutura fina registrada em rádio com cada etapa da explosão. Resultados preliminares mostraram que, na fase pré-flare, as estruturas finas apresentaram taxa de deriva negativa (~ 70-190 MHz/s). As emissões tipo "zebra" concentram-se na fase de descida do primeiro pico impulsivo e na de subida do segundo pico. Enquanto que as emissões tipo "fibra" ocorrem em ambas fases, mas preferivelmente durante a fase de descida. Os resultados serão apresentados e discutidos.

  22. Geospatial Analysis of Pediatric EMS Run Density and Endotracheal Intubation

    PubMed Central

    Hansen, Matthew; Loker, William; Warden, Craig

    2016-01-01

    Introduction The association between geographic factors, including transport distance, and pediatric emergency medical services (EMS) run clustering on out-of-hospital pediatric endotracheal intubation is unclear. The objective of this study was to determine if endotracheal intubation procedures are more likely to occur at greater distances from the hospital and near clusters of pediatric calls. Methods This was a retrospective observational study including all EMS runs for patients less than 18 years of age from 2008 to 2014 in a geographically large and diverse Oregon county that includes densely populated urban areas near Portland and remote rural areas. We geocoded scene addresses using the automated address locator created in the cloud-based mapping platform ArcGIS, supplemented with manual address geocoding for remaining cases. We then use the Getis-Ord Gi spatial statistic feature in ArcGIS to map statistically significant spatial clusters (hot spots) of pediatric EMS runs throughout the county. We then superimposed all intubation procedures performed during the study period on maps of pediatric EMS-run hot spots, pediatric population density, fire stations, and hospitals. We also performed multivariable logistic regression to determine if distance traveled to the hospital was associated with intubation after controlling for several confounding variables. Results We identified a total of 7,797 pediatric EMS runs during the study period and 38 endotracheal intubations. In univariate analysis we found that patients who were intubated were similar to those who were not in gender and whether or not they were transported to a children’s hospital. Intubated patients tended to be transported shorter distances and were older than non-intubated patients. Increased distance from the hospital was associated with reduced odds of intubation after controlling for age, sex, scene location, and trauma system entry status in a multivariate logistic regression. The

  23. Speaker verification using combined acoustic and EM sensor signal processing

    SciTech Connect

    Ng, L C; Gable, T J; Holzrichter, J F

    2000-11-10

    Low Power EM radar-like sensors have made it possible to measure properties of the human speech production system in real-time, without acoustic interference. This greatly enhances the quality and quantity of information for many speech related applications. See Holzrichter, Burnett, Ng, and Lea, J. Acoustic. SOC. Am . 103 ( 1) 622 (1998). By combining the Glottal-EM-Sensor (GEMS) with the Acoustic-signals, we've demonstrated an almost 10 fold reduction in error rates from a speaker verification system experiment under a moderate noisy environment (-10dB).

  24. Low Bandwidth Vocoding using EM Sensor and Acoustic Signal Processing

    SciTech Connect

    Ng, L C; Holzrichter, J F; Larson, P E

    2001-10-25

    Low-power EM radar-like sensors have made it possible to measure properties of the human speech production system in real-time, without acoustic interference [1]. By combining these data with the corresponding acoustic signal, we've demonstrated an almost 10-fold bandwidth reduction in speech compression, compared to a standard 2.4 kbps LPC10 protocol used in the STU-III (Secure Terminal Unit, third generation) telephone. This paper describes a potential EM sensor/acoustic based vocoder implementation.

  1. Developments in the EM-CCD camera for OGRE

    NASA Astrophysics Data System (ADS)

    Tutt, James H.; McEntaffer, Randall L.; DeRoo, Casey; Schultz, Ted; Miles, Drew M.; Zhang, William; Murray, Neil J.; Holland, Andrew D.; Cash, Webster; Rogers, Thomas; O'Dell, Steve; Gaskin, Jessica; Kolodziejczak, Jeff; Evagora, Anthony M.; Holland, Karen; Colebrook, David

    2014-07-01

    The Off-plane Grating Rocket Experiment (OGRE) is a sub-orbital rocket payload designed to advance the development of several emerging technologies for use on space missions. The payload consists of a high resolution soft X-ray spectrometer based around an optic made from precision cut and ground, single crystal silicon mirrors, a module of off-plane gratings and a camera array based around Electron Multiplying CCD (EM-CCD) technology. This paper gives an overview of OGRE with emphasis on the detector array; specifically this paper will address the reasons that EM-CCDs are the detector of choice and the advantages and disadvantages that this technology offers.

  2. Item Parameter Estimation via Marginal Maximum Likelihood and an EM Algorithm: A Didactic.

    ERIC Educational Resources Information Center

    Harwell, Michael R.; And Others

    1988-01-01

    The Bock and Aitkin Marginal Maximum Likelihood/EM (MML/EM) approach to item parameter estimation is an alternative to the classical joint maximum likelihood procedure of item response theory. This paper provides the essential mathematical details of a MML/EM solution and shows its use in obtaining consistent item parameter estimates. (TJH)

  3. 7 CFR 1945.35 - Special EM loan training.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... Agriculture Regulations of the Department of Agriculture (Continued) RURAL HOUSING SERVICE, RURAL BUSINESS...) PROGRAM REGULATIONS (CONTINUED) EMERGENCY Disaster Assistance-General § 1945.35 Special EM loan training. (a) General. When it is evident that a large number of farmers were affected by a widespread...

  4. Reservoir characterization and steam flood monitoring with crosshole EM

    SciTech Connect

    Wilt, M.; Torres-Verdin, C.

    1995-06-01

    Crosshole electromagnetic (EM) imaging is applied to reservoir characterization and steam flood monitoring in a central California oil field. Steam was injected into three stacked eastward-dipping, unconsolidated oil sands within the upper 200 m. The steam plume is expected to develop as an ellipse aligned with the regional northwest-southeast strike. EM measurements were made from two fiberglass-cased observation wells straddling the steam injector on a northeast-southwest profile using the LLNL frequency domain crosshole EM system. Field data were collected before the initiation of a steam drive to map the distribution of the oil sands and then 6 and 12 months later to monitor the progress of the steam chest. Resistivity images derived from the EM data before steam injection clearly delineate the distribution and dipping structure on the target oil sands. Difference images, from data collected before and after steam flooding, show resistivity changes that indicate that the steam chest has developed only in the deeper oil sands although steam injection occurred in all three sand layers.

  5. 7 CFR 1945.20 - Making EM loans available.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 13 2010-01-01 2009-01-01 true Making EM loans available. 1945.20 Section 1945.20 Agriculture Regulations of the Department of Agriculture (Continued) RURAL HOUSING SERVICE, RURAL BUSINESS-COOPERATIVE SERVICE, RURAL UTILITIES SERVICE, AND FARM SERVICE AGENCY, DEPARTMENT OF AGRICULTURE...

  6. Functionalized anatomical models for EM-neuron Interaction modeling.

    PubMed

    Neufeld, Esra; Cassará, Antonino Mario; Montanaro, Hazael; Kuster, Niels; Kainz, Wolfgang

    2016-06-21

    The understanding of interactions between electromagnetic (EM) fields and nerves are crucial in contexts ranging from therapeutic neurostimulation to low frequency EM exposure safety. To properly consider the impact of in vivo induced field inhomogeneity on non-linear neuronal dynamics, coupled EM-neuronal dynamics modeling is required. For that purpose, novel functionalized computable human phantoms have been developed. Their implementation and the systematic verification of the integrated anisotropic quasi-static EM solver and neuronal dynamics modeling functionality, based on the method of manufactured solutions and numerical reference data, is described. Electric and magnetic stimulation of the ulnar and sciatic nerve were modeled to help understanding a range of controversial issues related to the magnitude and optimal determination of strength-duration (SD) time constants. The results indicate the importance of considering the stimulation-specific inhomogeneous field distributions (especially at tissue interfaces), realistic models of non-linear neuronal dynamics, very short pulses, and suitable SD extrapolation models. These results and the functionalized computable phantom will influence and support the development of safe and effective neuroprosthetic devices and novel electroceuticals. Furthermore they will assist the evaluation of existing low frequency exposure standards for the entire population under all exposure conditions. PMID:27224508

  7. Functionalized anatomical models for EM-neuron Interaction modeling

    NASA Astrophysics Data System (ADS)

    Neufeld, Esra; Cassará, Antonino Mario; Montanaro, Hazael; Kuster, Niels; Kainz, Wolfgang

    2016-06-01

    The understanding of interactions between electromagnetic (EM) fields and nerves are crucial in contexts ranging from therapeutic neurostimulation to low frequency EM exposure safety. To properly consider the impact of in vivo induced field inhomogeneity on non-linear neuronal dynamics, coupled EM-neuronal dynamics modeling is required. For that purpose, novel functionalized computable human phantoms have been developed. Their implementation and the systematic verification of the integrated anisotropic quasi-static EM solver and neuronal dynamics modeling functionality, based on the method of manufactured solutions and numerical reference data, is described. Electric and magnetic stimulation of the ulnar and sciatic nerve were modeled to help understanding a range of controversial issues related to the magnitude and optimal determination of strength-duration (SD) time constants. The results indicate the importance of considering the stimulation-specific inhomogeneous field distributions (especially at tissue interfaces), realistic models of non-linear neuronal dynamics, very short pulses, and suitable SD extrapolation models. These results and the functionalized computable phantom will influence and support the development of safe and effective neuroprosthetic devices and novel electroceuticals. Furthermore they will assist the evaluation of existing low frequency exposure standards for the entire population under all exposure conditions.

  8. Texas Hold 'em Online Poker: A Further Examination

    ERIC Educational Resources Information Center

    Hopley, Anthony A. B.; Dempsey, Kevin; Nicki, Richard

    2012-01-01

    Playing Texas Hold 'em Online Poker (THOP) is on the rise. However, there is relatively little research examining factors that contribute to problem gambling in poker players. The aim of this study was to extend the research findings of Hopley and Nicki (2010). The negative mood states of depression, anxiety and stress were found to be linked to…

  9. Discussion of "The Case for the Median Fragment Size as a Better Fragment Size Descriptor than the Mean" by Finn Ouchterlony, Rock Mech Rock Eng, 2015. doi:10.1007/s00603-015-0722-1

    NASA Astrophysics Data System (ADS)

    Spathis, A. T.

    2016-01-01

    Ouchterlony (The Case for the Median Fragment Size as a Better Fragment Size Descriptor than the Mean, Rock Mech Rock Eng, 2015. doi: 10.1007/s00603-015-0722-1) argues that the median is preferred over the mean as a measure of central tendency of the rock fragmentation size distribution produced by blasting. This discussion suggests that neither is favoured over the other. Indeed, for distributions where both exist, they may be found in terms of each other, either by an analytical expression or by numerical calculation.

  10. Geophysical Exploration of Castle Remains in Barwałd Górny (Near Kalwaria Zebrzydowska, Poland) Using Electrical Resistivity Tomography (ERT) with Assistance of Depth of Investigation Index (DOI) Method.

    NASA Astrophysics Data System (ADS)

    Glazer, Michał; Kula, Damian; Saternus, Robert; Lewicki, Paweł

    2014-09-01

    In March of 2014 at ruins of the 14th century castle, situated at the top of Mount Żar in Małopolska region, Poland, geophysical surveys were performed. Surveys were planned to investigate remains of the castle that could remain in the ground. Electrical Resistivity Tomography method was used there. In the paper 4 sections have been presented. During interpretation, as the supporting method, maps of Depth-of-Investigation (DOI) index have been used. Results of the surveys can point out potential remains of the castle walls and ruins of buildings that were situated in the stronghold

  11. Airborne EM for geothermal and hydrogeological mapping

    NASA Astrophysics Data System (ADS)

    Menghini, A.; Manzella, A.; Viezzoli, A.; Montanari, D.; Maggi, S.

    2012-12-01

    Within the "VIGOR" project, aimed at assessing the geothermal potential of four regions in southern Italy, Airborne EM data have been acquired, modeled and interpreted. The system deployed was SkyTEM, a time-domain helicopter electromagnetic system designed for hydrogeophysical, environmental and mineral investigations. The AEM data provide, after data acquisition, analysis, processing, and modeling, a distribution volume of electrical resistivity, spanning an investigation depth from ground surface of few hundred meters, depending on resistivity condition. Resistivity is an important physical parameter for geothermal investigation, since it proved to be very effective in mapping anomalies due to hydrothermal fluid circulation, which usually has high salt content and produces clayey alteration minerals. Since the project required, among other issues, to define geothermal resources at shallow level, it was decided to perform a test with an airborne electromagnetic geophysical survey, to verify the advantages offered by the system in covering large areas in a short time. The geophysical survey was carried out in Sicily, Italy, in late 2011, over two test sites named "Termini" and "Western Sicily". The two areas were chosen on different basis. "Termini" area is covered by extensive geological surveys, and was going to be investigated also by means of electrical tomography in its northern part. Since geological condition of Sicily, even at shallow depth, is very complex, this area provided a good place for defining the resistivity values of the main geological units outcropping in the region. "Termini" survey has been also an occasion to define relations between resistivity distribution, lithological units and thermal conductivity. The "Western Sicily" area cover the main thermal manifestations of western Sicily, and the research target was to establish whether they are characterized by common hydrogeological or tectonic features that could be mapped by resistivity

  12. Development of the Emergency Medical Services Role Identity Scale (EMS-RIS).

    PubMed

    Donnelly, Elizabeth A; Siebert, Darcy; Siebert, Carl

    2015-01-01

    This article describes the development and validation of the theoretically grounded Emergency Medical Services Role Identity Scale (EMS-RIS), which measures four domains of EMS role identity. The EMS-RIS was developed using a mixed methods approach. Key informants informed item development and the scale was validated using a representative probability sample of EMS personnel. Factor analyses revealed a conceptually consistent, four-factor solution with sound psychometric properties as well as evidence of convergent and discriminant validities. Social workers work with EMS professionals in crisis settings and as their counselors when they are distressed. The EMS-RIS provides useful information for the assessment of and intervention with distressed EMS professionals, as well as how role identity may influence occupational stress. PMID:25760489

  13. Nonlinear Smoothing and the EM Algorithm for Positive Integral Equations of the First Kind

    SciTech Connect

    Eggermont, P. P. B.

    1999-01-15

    We study a modification of the EMS algorithm in which each step of the EMS algorithm is preceded by a nonlinear smoothing step of the form Nf-exp(S*log f) , where S is the smoothing operator of the EMS algorithm. In the context of positive integral equations (a la positron emission tomography) the resulting algorithm is related to a convex minimization problem which always admits a unique smooth solution, in contrast to the unmodified maximum likelihood setup. The new algorithm has slightly stronger monotonicity properties than the original EM algorithm. This suggests that the modified EMS algorithm is actually an EM algorithm for the modified problem. The existence of a smooth solution to the modified maximum likelihood problem and the monotonicity together imply the strong convergence of the new algorithm. We also present some simulation results for the integral equation of stereology, which suggests that the new algorithm behaves roughly like the EMS algorithm.

  14. GPS computer navigators to shorten EMS response and transport times.

    PubMed

    Ota, F S; Muramatsu, R S; Yoshida, B H; Yamamoto, L G

    2001-05-01

    GPS (global positioning satellite system to determine one's position on earth) units have become inexpensive and compact. The purpose of this study is to assess the effectiveness of a GPS enhanced computer street map navigator to improve the ability of EMS drivers in an urban setting to locate their destination and shorten response times. For part I, residential addresses in the city were randomly selected from a telephone directory. Two driver/navigator teams were assigned to drive to the address adhering to speed limits. One team used a standard street map, whereas the other team used a GPS computer navigator. The travel time and distance of the runs were compared. For part II, the computer GPS navigator was placed on an ambulance to supplement their normal methods of navigation to find the address requesting EMS. After the run was completed, EMS providers were interviewed to determine their opinion of whether the GPS navigator was helpful. For part I the results showed that in the 29 initial test runs, comparing the GPS team versus the standard map team, the mean distances traveled were 8.7 versus 9.0 kilometers (not significant) and the mean travel times were 13.5 versus 14.6 minutes (P=.02), respectively. The GPS team arrived faster in 72% runs. For part II the results showed that most EMS providers surveyed noted that the GPS computer navigator enhanced their ability to find the destination and all EMS providers acknowledged that it would enhance their ability to find a destination in an area in which they were unfamiliar. These results suggest that a portable GPS computer navigator system is helpful and can enhance the ability of prehospital care providers to locate their destination. Because these units are accurate and inexpensive, GPS computer navigators may be a valuable tool in reducing pre-hospital transport times. PMID:11326345

  15. The B and Be States of the Star EM Cepheus

    NASA Astrophysics Data System (ADS)

    Kjurkchieva, Diana; Marchev, Dragomir; Sigut, T. A. A.; Dimitrov, Dinko

    2016-09-01

    We present 11 yr of high-resolution, spectroscopic observations for the star EM Cep. EM Cep switches between B and Be star states, as revealed by the level of Hα emission, but spends most of its time in the B star state. EM Cep has been considered to be an eclipsing, near-contact binary of nearly equal-mass B stars in order to reproduce regular photometric variations; however, this model is problematic due to the lack of any observed Doppler shift in the spectrum. Our observations confirm that there are no apparent Doppler shifts in the wide spectral lines Hα and He i λ6678 in either the B or Be star states. The profiles of He i λ6678 typically exhibited a filled-in absorption core, but we detected weak emission in this line during the highest Be state. Given the lack of observed Doppler shifts, we model EM Cep as an isolated Be star with a variable circumstellar disk. We can reproduce the observed Hα emission profiles over the 11 yr period reasonably well with disk masses on the order of 3{--}10× {10}-11 {M}* in the Be state with the circumstellar disk seen at an inclination of 78° to the line of sight. From a disk ejection episode in 2014, we estimate a mass-loss rate of ≈ 3× {10}-9 {M}ȯ {{yr}}-1. The derived disk density parameters are typical of those found for the classical Be stars. We therefore suggest that the EM Cep is a classical Be star and that its photometric variations are the result of β Cep or nonradial pulsations.

  16. Similarity-regulation of OS-EM for accelerated SPECT reconstruction.

    PubMed

    Vaissier, P E B; Beekman, F J; Goorden, M C

    2016-06-01

    Ordered subsets expectation maximization (OS-EM) is widely used to accelerate image reconstruction in single photon emission computed tomography (SPECT). Speedup of OS-EM over maximum likelihood expectation maximization (ML-EM) is close to the number of subsets used. Although a high number of subsets can shorten reconstruction times significantly, it can also cause severe image artifacts such as improper erasure of reconstructed activity if projections contain few counts. We recently showed that such artifacts can be prevented by using a count-regulated OS-EM (CR-OS-EM) algorithm which automatically adapts the number of subsets for each voxel based on the estimated number of counts that the voxel contributed to the projections. While CR-OS-EM reached high speed-up over ML-EM in high-activity regions of images, speed in low-activity regions could still be very slow. In this work we propose similarity-regulated OS-EM (SR-OS-EM) as a much faster alternative to CR-OS-EM. SR-OS-EM also automatically and locally adapts the number of subsets, but it uses a different criterion for subset regulation: the number of subsets that is used for updating an individual voxel depends on how similar the reconstruction algorithm would update the estimated activity in that voxel with different subsets. Reconstructions of an image quality phantom and in vivo scans show that SR-OS-EM retains all of the favorable properties of CR-OS-EM, while reconstruction speed can be up to an order of magnitude higher in low-activity regions. Moreover our results suggest that SR-OS-EM can be operated with identical reconstruction parameters (including the number of iterations) for a wide range of count levels, which can be an additional advantage from a user perspective since users would only have to post-filter an image to present it at an appropriate noise level. PMID:27206135

  17. Similarity-regulation of OS-EM for accelerated SPECT reconstruction

    NASA Astrophysics Data System (ADS)

    Vaissier, P. E. B.; Beekman, F. J.; Goorden, M. C.

    2016-06-01

    Ordered subsets expectation maximization (OS-EM) is widely used to accelerate image reconstruction in single photon emission computed tomography (SPECT). Speedup of OS-EM over maximum likelihood expectation maximization (ML-EM) is close to the number of subsets used. Although a high number of subsets can shorten reconstruction times significantly, it can also cause severe image artifacts such as improper erasure of reconstructed activity if projections contain few counts. We recently showed that such artifacts can be prevented by using a count-regulated OS-EM (CR-OS-EM) algorithm which automatically adapts the number of subsets for each voxel based on the estimated number of counts that the voxel contributed to the projections. While CR-OS-EM reached high speed-up over ML-EM in high-activity regions of images, speed in low-activity regions could still be very slow. In this work we propose similarity-regulated OS-EM (SR-OS-EM) as a much faster alternative to CR-OS-EM. SR-OS-EM also automatically and locally adapts the number of subsets, but it uses a different criterion for subset regulation: the number of subsets that is used for updating an individual voxel depends on how similar the reconstruction algorithm would update the estimated activity in that voxel with different subsets. Reconstructions of an image quality phantom and in vivo scans show that SR-OS-EM retains all of the favorable properties of CR-OS-EM, while reconstruction speed can be up to an order of magnitude higher in low-activity regions. Moreover our results suggest that SR-OS-EM can be operated with identical reconstruction parameters (including the number of iterations) for a wide range of count levels, which can be an additional advantage from a user perspective since users would only have to post-filter an image to present it at an appropriate noise level.

  18. Observação do abrilhantamento de limbo solar e de estruturas filamentares em 48 ghz utilizando a técnica de regularização adaptativa

    NASA Astrophysics Data System (ADS)

    Machado, W. R. S.; Mascarenhas, N.; Costa, J. E. R.; Silva, A. V. R.

    2003-08-01

    O radiotelescópio do Itapetinga tem sido utilizado em campanhas de observações de explosões solares gerando um grande número de mapas diários em 48 GHz como sub-produto destas observações. A resolução espacial do telescópio de 14m do Itapetinga nesta freqüência é de aproximadamente dois minutos de arco. Estruturas de interesse para análise da atmosfera solar quiescente tais como os filamentos e o anel de abrilhantamento do limbo são de dimensão angular moderada da ordem ou ligeiramente menores que a resolução do telescópio. É conhecido que a convolução da função de espalhamento do telescópio, PSF (padrão de ganho do feixe) borra as estruturas de dimensão angular abaixo do HPBW (largura a meia potência do feixe) e portanto é comum a busca por técnicas de restauração que eliminem pelo menos em parte este borramento. Estudamos a restauração destas radioimagens usando a técnica de regularização adaptativa e os resultados ressaltam estas estruturas espaciais de pequeno contraste. O algoritmo da regularização adaptativa faz uso de k imagens, chamadas protótipos, obtidas através da variação de parâmetros de um filtro de regularização. Para controle da qualidade da restauração utilizamos uma imagem de alta resolução espacial obtida na linha H-a e a PSF do Itapetinga para borrá-la. Pequenos desvios, entre a PSF utilizada para o borramento e a PSF utilizada na restauração, produziram alguns desvios notáveis na imagem restaurada porém a adição de ruído nas simulações de restauração foram mais influentes no cálculo da rugosidade da imagem e portanto mais limitante para a restauração. Apresentamos como nosso primeiro resultado uma imagem em 48 GHz com a presença clara do abrilhantamento de limbo que não estava evidente na imagem original e traços de estruturas filamentares, porém ainda sem grande evidência.

  19. Service Discovery Framework Supported by EM Algorithm and Bayesian Classifier

    NASA Astrophysics Data System (ADS)

    Peng, Yanbin

    Service oriented computing has become the main stream research field nowadays. Meanwhile, machine learning is a promising AI technology which can enhance the performance of traditional algorithm. Therefore, aiming at solving service discovery problem, this paper imports Bayesian classifier to web service discovery framework, which can improve service querying speed. In this framework, services in service library become training set of Bayesian classifier, service query becomes a testing sample. Service matchmaking process can be executed in related service class, which has fewer services, thus can save time. Due to don't know the class of service in training set, EM algorithm is used to estimate prior probability and likelihood functions. Experiment results show that the EM algorithm and Bayesian classifier supported method outperforms other methods in time complexity.

  20. Magen David Adom--the EMS in Israel.

    PubMed

    Ellis, Daniel Y; Sorene, Eliot

    2008-01-01

    Israel is a small country with a population of around 7 million. The sole EMS provider for Israel is Magen David Adom (MDA) (translated as 'Red Shield of David'). MDA also carries out the functions of a National Society (similar to the Red Cross) and provides all the blood and blood product services for the country. Nationwide, the organisation responds to over 1000 emergency calls a day and uses doctors, paramedics, emergency medical technicians and volunteers. Local geopolitics has meant that MDA has to be prepared for anything from everyday emergency calls to suicide bombings and regional wars. MDA also prides itself in being able to rapidly assemble and dispatch mobile aid teams to scenes of international disasters. Such a broad range of activities is unusual for a single EMS organisation. PMID:17767990

  1. Superconducting Electromagnetic Suspension (EMS) system for Grumman Maglev concept

    NASA Technical Reports Server (NTRS)

    Kalsi, Swarn S.

    1994-01-01

    The Grumman developed Electromagnetic Suspension (EMS) Maglev system has the following key characteristics: a large operating airgap--40 mm; levitation at all speeds; both high speed and low speed applications; no deleterious effects on SC coils at low vehicle speeds; low magnetic field at the SC coil--less than 0.35 T; no need to use non-magnetic/non-metallic rebar in the guideway structure; low magnetic field in passenger cabin--approximately 1 G; low forces on the SC coil; employs state-of-the-art NbTi wire; no need for an active magnet quench protection system; and lower weight than a magnet system with copper coils. The EMS Maglev described in this paper does not require development of any new technologies. The system could be built with the existing SC magnet technology.

  2. Environmental Restoration and Waste Management (EM) program: An introduction

    SciTech Connect

    Not Available

    1990-12-01

    This booklet introduces the reader to the mission and functions of a major new unit within the US Department of Energy (DOE): the Office of Environmental Restoration and Waste Management (EM). The Secretary of Energy established EM in November 1989, implementing a central purpose of DOE's first annual Environmental Restoration and Waste Management Five-Year Plan, which had appeared three months earlier. The contents of this booklet, and their arrangement, reflect the annual update of the Five-Year Plan. The Five-Year Plan supports DOE's strategy for meeting its 30-year compliance and cleanup goal. This strategy involves: focusing DOE's activities on eliminating or reducing known or recognized potential risks to worker and public health and the environment, containing or isolating, removing, or detoxifying onsite and offsite contamination, and developing technology to achieve DOE's environmental goals.

  3. Generalized single-particle cryo-EM--a historical perspective.

    PubMed

    Frank, Joachim

    2016-02-01

    This is a brief account of the earlier history of single-particle cryo-EM of biological molecules lacking internal symmetry, which goes back to the mid-seventies. The emphasis of this review is on the mathematical concepts and computational approaches. It is written as the field experiences a turning point in the wake of the introduction of digital cameras capable of single electron counting, and near-atomic resolution can be reached even for smaller molecules. PMID:26566976

  4. EMS-STARS: Emergency Medical Services "Superuser" Transport Associations: An Adult Retrospective Study.

    PubMed

    Hall, M Kennedy; Raven, Maria C; Hall, Jane; Yeh, Clement; Allen, Elaine; Rodriguez, Robert M; Tangherlini, Niels L; Sporer, Karl A; Brown, John F

    2015-01-01

    Abstract Objective. Emergency medical services (EMS) "superusers" -those who use EMS services at extremely high rates -have not been well characterized. Recent interest in the small group of individuals who account for a disproportionate share of health-care expenditures has led to research on frequent users of emergency departments and other health services, but little research has been done regarding those who use EMS services. To inform policy and intervention implementation, we undertook a descriptive analysis of EMS superusers in a large urban community. In this paper we compare EMS superusers to low, moderate, and high users to characterize factors contributing to EMS use. We also estimate the financial impact of EMS superusers. Methods. We conducted a retrospective cross-sectional study based on 1 year of data from an urban EMS system. Data for all EMS encounters with patients age ≥18 years were extracted from electronic records generated on scene by paramedics. We identified demographic and clinical variables associated with levels of EMS use. EMS users were characterized by the annual number of EMS encounters: low (1), moderate (2-4), high (5-14), and superusers (≥15). In addition, we performed a financial analysis using San Francisco Fire Department (SFFD) 2009 charge and reimbursement data. Results. A total of 31,462 adults generated 43,559 EMS ambulance encounters, which resulted in 39,107 transports (a 90% transport rate). Encounters for general medical reasons were common among moderate and high users and less frequent among superusers and low users, while alcohol use was exponentially correlated with encounter frequency. Superusers were significantly younger than moderate EMS users, and more likely to be male. The superuser group created a significantly higher financial burden/person than any other group, comprising 0.3% of the study population, but over 6% of annual EMS charges and reimbursements. Conclusions. In this retrospective study, adult

  5. Improving EM&V for Energy Efficiency Programs (Fact Sheet)

    SciTech Connect

    Not Available

    2012-07-01

    This fact sheet describes the objectives of the U.S. Department of Energy Uniform Methods Project to bring consistency to energy savings calculations in U.S. energy efficiency programs. The U.S. Department of Energy (DOE) is developing a framework and a set of protocols for determining gross energy savings from energy efficiency measures and programs. The protocols represent a refinement of the body of knowledge supporting energy efficiency evaluation, measurement, and verification (EM&V) activities. They have been written by technical experts within the field and reviewed by industry experts. Current EM&V practice allows for multiple methods for calculating energy savings. These methods were developed to meet the needs of energy efficiency program administrators and regulators. Although they served their original objectives well, they have resulted in inconsistent and incomparable savings results - even for identical measures. The goal of the Uniform Methods Project is to strengthen the credibility of energy savings determinations by improving EM&V, increasing the consistency and transparency of how energy savings are determined.

  6. The US DOE-EM International Program - 13004

    SciTech Connect

    Elmetti, Rosa R.; Han, Ana M.; Williams, Alice C.

    2013-07-01

    The U.S. Department of Energy (DOE) Office of Environmental Management (EM) conducts international collaboration activities in support of U.S. policies and objectives regarding the accelerated risk reduction and remediation of environmental legacy of the nations' nuclear weapons program and government sponsored nuclear energy research. The EM International Program supported out of the EM Office of the Associate Principal Deputy Assistant Secretary pursues collaborations with foreign government organizations, educational institutions and private industry to assist in identifying technologies and promote international collaborations that leverage resources and link international experience and expertise. In fiscal year (FY) 2012, the International Program awarded eight international collaborative projects for work scope spanning waste processing, groundwater and soil remediation, deactivation and decommissioning (D and D) and nuclear materials disposition initiatives to seven foreign organizations. Additionally, the International Program's scope and collaboration opportunities were expanded to include technical as well as non-technical areas. This paper will present an overview of the on-going tasks awarded in FY 2012 and an update of upcoming international activities and opportunities for expansion into FY 2013 and beyond. (authors)

  7. Volta phase plate cryo-EM of the small protein complex Prx3.

    PubMed

    Khoshouei, Maryam; Radjainia, Mazdak; Phillips, Amy J; Gerrard, Juliet A; Mitra, Alok K; Plitzko, Jürgen M; Baumeister, Wolfgang; Danev, Radostin

    2016-01-01

    Cryo-EM of large, macromolecular assemblies has seen a significant increase in the numbers of high-resolution structures since the arrival of direct electron detectors. However, sub-nanometre resolution cryo-EM structures are rare compared with crystal structure depositions, particularly for relatively small particles (<400 kDa). Here we demonstrate the benefits of Volta phase plates for single-particle analysis by time-efficient cryo-EM structure determination of 257 kDa human peroxiredoxin-3 dodecamers at 4.4 Å resolution. The Volta phase plate improves the applicability of cryo-EM for small molecules and accelerates structure determination. PMID:26817416

  8. Standard errors for EM estimates in generalized linear models with random effects.

    PubMed

    Friedl, H; Kauermann, G

    2000-09-01

    A procedure is derived for computing standard errors of EM estimates in generalized linear models with random effects. Quadrature formulas are used to approximate the integrals in the EM algorithm, where two different approaches are pursued, i.e., Gauss-Hermite quadrature in the case of Gaussian random effects and nonparametric maximum likelihood estimation for an unspecified random effect distribution. An approximation of the expected Fisher information matrix is derived from an expansion of the EM estimating equations. This allows for inferential arguments based on EM estimates, as demonstrated by an example and simulations. PMID:10985213

  9. Modeling of MHD edge containment in strip casting with ELEKTRA and CaPS-EM codes

    SciTech Connect

    Chang, F. C.

    2000-01-12

    This paper presents modeling studies of magnetohydrodynamics analysis in twin-roll casting. Argonne National Laboratory (ANL) and ISPAT Inland Inc. (Inland), formerly Inland Steel Co., have worked together to develop a three-dimensional (3-D) computer model that can predict eddy currents, fluid flows, and liquid metal containment of an electromagnetic (EM) edge containment device. The model was verified by comparing predictions with experimental results of liquid metal containment and fluid flow in EM edge dams (EMDs) that were designed at Inland for twin-roll casting. This mathematical model can significantly shorten casting research on the use of EM fields for liquid metal containment and control. The model can optimize the EMD design so it is suitable for application, and minimize expensive time-consuming full-scale testing. Numerical simulation was performed by coupling a 3-D finite-element EM code (ELEKTRA) and a 3-D finite-difference fluids code (CaPS-EM) to solve heat transfer, fluid flow, and turbulence transport in a casting process that involves EM fields. ELEKTRA can predict the eddy-current distribution and the EM forces in complex geometries. CaPS-EM can model fluid flows with free surfaces. The computed 3-D magnetic fields and induced eddy currents in ELEKTRA are used as input to temperature- and flow-field computations in CaPS-EM. Results of the numerical simulation compared well with measurements obtained from both static and dynamic tests.

  10. Volta phase plate cryo-EM of the small protein complex Prx3

    NASA Astrophysics Data System (ADS)

    Khoshouei, Maryam; Radjainia, Mazdak; Phillips, Amy J.; Gerrard, Juliet A.; Mitra, Alok K.; Plitzko, Jürgen M.; Baumeister, Wolfgang; Danev, Radostin

    2016-01-01

    Cryo-EM of large, macromolecular assemblies has seen a significant increase in the numbers of high-resolution structures since the arrival of direct electron detectors. However, sub-nanometre resolution cryo-EM structures are rare compared with crystal structure depositions, particularly for relatively small particles (<400 kDa). Here we demonstrate the benefits of Volta phase plates for single-particle analysis by time-efficient cryo-EM structure determination of 257 kDa human peroxiredoxin-3 dodecamers at 4.4 Å resolution. The Volta phase plate improves the applicability of cryo-EM for small molecules and accelerates structure determination.

  11. “Rice Is Essential but Tiresome; You Should Get Some Noodles”: Doi Moi and the Political Economy of Men’s Extramarital Sexual Relations and Marital HIV Risk in Hanoi, Vietnam

    PubMed Central

    Phinney, Harriet M.

    2008-01-01

    Research from around the world has suggested that married women’s greatest risk for contracting HIV is from having sexual intercourse with their husbands. On the basis of 6 months of ethnographic research in Hanoi, Vietnam, I argue that the contemporary nature of the HIV epidemic in Hanoi is shaped by 3 interrelated policies implemented in 1986 as part of the government’s new economic policy, Doi Moi (Renovation). Together, these policies structure men’s opportunities for extramarital sexual relations and encourage wives to acquiesce to their husbands’ sexual infidelity, putting both at risk of HIV. I propose 4 structural intervention strategies that address the policies that contribute to men’s opportunities for extramarital liaisons and to marital HIV risk. PMID:18309136

  12. Design of the Dutch Obesity Intervention in Teenagers (NRG-DOiT): systematic development, implementation and evaluation of a school-based intervention aimed at the prevention of excessive weight gain in adolescents

    PubMed Central

    Singh, Amika S; Chin A Paw, Marijke JM; Kremers, Stef PJ; Visscher, Tommy LS; Brug, Johannes; van Mechelen, Willem

    2006-01-01

    Background Only limited data are available on the development, implementation, and evaluation processes of weight gain prevention programs in adolescents. To be able to learn from successes and failures of such interventions, integral written and published reports are needed. Methods Applying the Intervention Mapping (IM) protocol, this paper describes the development, implementation, and evaluation of the Dutch Obesity Intervention in Teenagers (DOiT), a school-based intervention program aimed at the prevention of excessive weight gain. The intervention focussed on the following health behaviours: (1) reduction of the consumption of sugar-sweetened beverages, (2) reduction of energy intake derived from snacks, (3) decrease of levels of sedentary behaviour, and (4) increase of levels of physical activity (i.e. active transport behaviour and sports participation). The intervention program consisted of an individual classroom-based component (i.e. an educational program, covering 11 lessons of both biology and physical education classes), and an environmental component (i.e. encouraging and supporting changes at the school canteens, as well as offering additional physical education classes). We evaluated the effectiveness of the intervention program using a randomised controlled trial design. We assessed the effects of the intervention on body composition (primary outcome measure), as well as on behaviour, behavioural determinants, and aerobic fitness (secondary outcome measures). Furthermore, we conducted a process evaluation. Discussion The development of the DOiT-intervention resulted in a comprehensive school-based weight gain prevention program, tailored to the needs of Dutch adolescents from low socio-economic background. PMID:17173701

  13. Covariance Matrix Estimation for the Cryo-EM Heterogeneity Problem*

    PubMed Central

    Katsevich, E.; Katsevich, A.; Singer, A.

    2015-01-01

    In cryo-electron microscopy (cryo-EM), a microscope generates a top view of a sample of randomly oriented copies of a molecule. The problem of single particle reconstruction (SPR) from cryo-EM is to use the resulting set of noisy two-dimensional projection images taken at unknown directions to reconstruct the three-dimensional (3D) structure of the molecule. In some situations, the molecule under examination exhibits structural variability, which poses a fundamental challenge in SPR. The heterogeneity problem is the task of mapping the space of conformational states of a molecule. It has been previously suggested that the leading eigenvectors of the covariance matrix of the 3D molecules can be used to solve the heterogeneity problem. Estimating the covariance matrix is challenging, since only projections of the molecules are observed, but not the molecules themselves. In this paper, we formulate a general problem of covariance estimation from noisy projections of samples. This problem has intimate connections with matrix completion problems and high-dimensional principal component analysis. We propose an estimator and prove its consistency. When there are finitely many heterogeneity classes, the spectrum of the estimated covariance matrix reveals the number of classes. The estimator can be found as the solution to a certain linear system. In the cryo-EM case, the linear operator to be inverted, which we term the projection covariance transform, is an important object in covariance estimation for tomographic problems involving structural variation. Inverting it involves applying a filter akin to the ramp filter in tomography. We design a basis in which this linear operator is sparse and thus can be tractably inverted despite its large size. We demonstrate via numerical experiments on synthetic datasets the robustness of our algorithm to high levels of noise. PMID:25699132

  14. Perda de massa em ventos empoeirados de estrelas supergigantes

    NASA Astrophysics Data System (ADS)

    Vidotto, A. A.; Jatenco-Pereira, V.

    2003-08-01

    Em praticamente todas as regiões do diagrama HR, as estrelas apresentam evidências observacionais de perda de massa. Na literatura, pode-se encontrar trabalhos que tratam tanto do diagnóstico da perda de massa como da construção de modelos que visam explicá-la. O amortecimento de ondas Alfvén tem sido utilizado como mecanismo de aceleração de ventos homogêneos. Entretanto, sabe-se que os envelopes de estrelas frias contêm grãos sólidos e moléculas. Com o intuito de estudar a interação entre as ondas Alfvén e a poeira e a sua conseqüência na aceleração do vento estelar, Falceta-Gonçalves & Jatenco-Pereira (2002) desenvolveram um modelo de perda de massa para estrelas supergigantes. Neste trabalho, apresentamos um estudo do modelo acima proposto para avaliar a dependência da taxa de perda de massa com alguns parâmetros iniciais como, por exemplo, a densidade r0, o campo magnético B0, o comprimento de amortecimento da onda L0, seu fluxo f0, entre outros. Sendo assim, aumentando f0 de 10% a partir de valores de referência, vimos que aumenta consideravelmente, enquanto que um aumento de mesmo valor em r0, B0 e L0 acarreta uma diminuição em .

  15. EM-21 Retrieval Knowledge Center: Waste Retrieval Challenges

    SciTech Connect

    Fellinger, Andrew P.; Rinker, Michael W.; Berglin, Eric J.; Minichan, Richard L.; Poirier, Micheal R.; Gauglitz, Phillip A.; Martin, Bruce A.; Hatchell, Brian K.; Saldivar, Eloy; Mullen, O Dennis; Chapman, Noel F.; Wells, Beric E.; Gibbons, Peter W.

    2009-04-10

    EM-21 is the Waste Processing Division of the Office of Engineering and Technology, within the U.S. Department of Energy’s (DOE) Office of Environmental Management (EM). In August of 2008, EM-21 began an initiative to develop a Retrieval Knowledge Center (RKC) to provide the DOE, high level waste retrieval operators, and technology developers with centralized and focused location to share knowledge and expertise that will be used to address retrieval challenges across the DOE complex. The RKC is also designed to facilitate information sharing across the DOE Waste Site Complex through workshops, and a searchable database of waste retrieval technology information. The database may be used to research effective technology approaches for specific retrieval tasks and to take advantage of the lessons learned from previous operations. It is also expected to be effective for remaining current with state-of-the-art of retrieval technologies and ongoing development within the DOE Complex. To encourage collaboration of DOE sites with waste retrieval issues, the RKC team is co-led by the Savannah River National Laboratory (SRNL) and the Pacific Northwest National Laboratory (PNNL). Two RKC workshops were held in the Fall of 2008. The purpose of these workshops was to define top level waste retrieval functional areas, exchange lessons learned, and develop a path forward to support a strategic business plan focused on technology needs for retrieval. The primary participants involved in these workshops included retrieval personnel and laboratory staff that are associated with Hanford and Savannah River Sites since the majority of remaining DOE waste tanks are located at these sites. This report summarizes and documents the results of the initial RKC workshops. Technology challenges identified from these workshops and presented here are expected to be a key component to defining future RKC-directed tasks designed to facilitate tank waste retrieval solutions.

  16. Single-particle cryo-EM at crystallographic resolution

    PubMed Central

    Cheng, Yifan

    2015-01-01

    Until only a few years ago, single-particle electron cryo-microscopy (cryo-EM) was usually not the first choice for many structural biologists due to its limited resolution in the range of nanometer to subnanometer. Now, this method rivals X-ray crystallography in terms of resolution and can be used to determine atomic structures of macromolecules that are either refractory to crystallization or difficult to crystallize in specific functional states. In this review, I discuss the recent breakthroughs in both hardware and software that transformed cryo-microscopy, enabling understanding of complex biomolecules and their functions at atomic level. PMID:25910205

  17. A compulsator driven rapid-fire EM-gun

    SciTech Connect

    Pratap, S.B.; Bird, W.L.

    1984-03-01

    A compulsator-driven railgun is an attractive alternative to the homopolar generator-inductor-switch configuration, especially for repetitive duty. A conceptual design of a rapid-fire EM-gun system is presented. The generator is sized to accelerate a 0.08-kg projectile to 2 to 3 km/s at a 60 pulse-per-second repetition rate. Initial design parameters are discussed, and example current and velocity waveforms are given. The generator is discharged at the proper phase angle to provide a current zero just as the projectile exits the muzzle of the railgun.

  18. EM Modelling of RF Propagation Through Plasma Plumes

    NASA Astrophysics Data System (ADS)

    Pandolfo, L.; Bandinelli, M.; Araque Quijano, J. L.; Vecchi, G.; Pawlak, H.; Marliani, F.

    2012-05-01

    Electric propulsion is a commercially attractive solution for attitude and position control of geostationary satellites. Hall-effect ion thrusters generate a localized plasma flow in the surrounding of the satellite, whose impact on the communication system needs to be qualitatively and quantitatively assessed. An electromagnetic modelling tool has been developed and integrated into the Antenna Design Framework- ElectroMagnetic Satellite (ADF-EMS). The system is able to guide the user from the plume definition phases through plume installation and simulation. A validation activity has been carried out and the system has been applied to the plume modulation analysis of SGEO/Hispasat mission.

  19. Developing State and National Evaluation Infrastructures- Guidance for the Challenges and Opportunities of EM&V

    SciTech Connect

    Schiller, Steven R.; Goldman, Charles A.

    2011-06-24

    Evaluating the impacts and effectiveness of energy efficiency programs is likely to become increasingly important for state policymakers and program administrators given legislative mandates and regulatory goals and increasing reliance on energy efficiency as a resource. In this paper, we summarize three activities that the authors have conducted that highlight the expanded role of evaluation, measurement and verification (EM&V): a study that identified and analyzed challenges in improving and scaling up EM&V activities; a scoping study that identified issues involved in developing a national efficiency EM&V standard; and lessons learned from providing technical assistance on EM&V issues to states that are ramping up energy efficiency programs. The lessons learned are summarized in 13 EM&V issues that policy makers should address in each jurisdiction and which are listed and briefly described. The paper also discusses how improving the effectiveness and reliability of EM&V will require additional capacity building, better access to existing EM&V resources, new methods to address emerging issues and technologies, and perhaps foundational documents and approaches to improving the credibility and cross jurisdictional comparability of efficiency investments. Two of the potential foundational documents discussed are a national EM&V standard or resource guide and regional deemed savings and algorithm databases.

  20. EMS Instructor Training Program. National Standard Curriculum. Instructor Guide. Student Guide.

    ERIC Educational Resources Information Center

    National Highway Traffic Safety Administration (DOT), Washington, DC.

    This guide for teaching a course to prepare emergency medical service (EMS) trainers focuses on the skills necessary to present any of the Department of Transportation (DOT), National Highway Traffic Safety Administration (NHTSA) EMS courses. Course topics are as follows: (1) introduction; (2) instructor roles and responsibilities; (3) legal…

  1. Method for evaluating compatibility of commercial electromagnetic (EM) microsensor tracking systems with surgical and imaging tables

    NASA Astrophysics Data System (ADS)

    Nafis, Christopher; Jensen, Vern; von Jako, Ron

    2008-03-01

    Electromagnetic (EM) tracking systems have been successfully used for Surgical Navigation in ENT, cranial, and spine applications for several years. Catheter sized micro EM sensors have also been used in tightly controlled cardiac mapping and pulmonary applications. EM systems have the benefit over optical navigation systems of not requiring a line-of-sight between devices. Ferrous metals or conductive materials that are transient within the EM working volume may impact tracking performance. Effective methods for detecting and reporting EM field distortions are generally well known. Distortion compensation can be achieved for objects that have a static spatial relationship to a tracking sensor. New commercially available micro EM tracking systems offer opportunities for expanded image-guided navigation procedures. It is important to know and understand how well these systems perform with different surgical tables and ancillary equipment. By their design and intended use, micro EM sensors will be located at the distal tip of tracked devices and therefore be in closer proximity to the tables. Our goal was to define a simple and portable process that could be used to estimate the EM tracker accuracy, and to vet a large number of popular general surgery and imaging tables that are used in the United States and abroad.

  2. Covariance Structure Model Fit Testing under Missing Data: An Application of the Supplemented EM Algorithm

    ERIC Educational Resources Information Center

    Cai, Li; Lee, Taehun

    2009-01-01

    We apply the Supplemented EM algorithm (Meng & Rubin, 1991) to address a chronic problem with the "two-stage" fitting of covariance structure models in the presence of ignorable missing data: the lack of an asymptotically chi-square distributed goodness-of-fit statistic. We show that the Supplemented EM algorithm provides a convenient…

  3. The Relationship between the Bock-Aitkin Procedure and the EM Algorithm for IRT Model Estimation.

    ERIC Educational Resources Information Center

    Hsu, Yaowen; Ackerman, Terry A.; Fan, Meichu

    It has previously been shown that the Bock-Aitkin procedure (R. Bock and M. Aitkin, 1981) is an instance of the EM algorithm when trying to find the marginal maximum likelihood estimate for a discrete latent ability variable (latent trait). In this paper, it is shown that the Bock-Aitkin procedure is a numerical implementation of the EM algorithm…

  4. Global Convergence of the EM Algorithm for Unconstrained Latent Variable Models with Categorical Indicators

    ERIC Educational Resources Information Center

    Weissman, Alexander

    2013-01-01

    Convergence of the expectation-maximization (EM) algorithm to a global optimum of the marginal log likelihood function for unconstrained latent variable models with categorical indicators is presented. The sufficient conditions under which global convergence of the EM algorithm is attainable are provided in an information-theoretic context by…

  5. Signaling of cell fate determination by the TPD1 small protein and EMS1 receptor kinase

    PubMed Central

    Jia, Gengxiang; Liu, Xiaodong; Owen, Heather A.; Zhao, Dazhong

    2008-01-01

    Sexual reproduction requires the specification of cells with distinct fates in plants and animals. The EMS1 (also known as EXS) leucine-rich repeat receptor-like kinase (LRR-RLK) and TPD1 small protein play key roles in regulating somatic and reproductive cell fate determination in Arabidopsis anthers. Here, we show that ectopic expression of TPD1 causes abnormal differentiation of somatic and reproductive cells in anthers. In addition, ectopic TPD1 activity requires functional EMS1. Yeast two-hybrid, pull-down, and coimmunoprecipitation analyses further demonstrate that TPD1 interacts with EMS1 in vitro and in vivo. Moreover, TPD1 induces EMS1 phosphorylation in planta. Thus, our results suggest that TPD1 serves as a ligand for the EMS1 receptor kinase to signal cell fate determination during plant sexual reproduction. PMID:18250314

  6. A Generalized Fast Frequency Sweep Algorithm for Coupled Circuit-EM Simulations

    SciTech Connect

    Rockway, J D; Champagne, N J; Sharpe, R M; Fasenfest, B

    2004-01-14

    Frequency domain techniques are popular for analyzing electromagnetics (EM) and coupled circuit-EM problems. These techniques, such as the method of moments (MoM) and the finite element method (FEM), are used to determine the response of the EM portion of the problem at a single frequency. Since only one frequency is solved at a time, it may take a long time to calculate the parameters for wideband devices. In this paper, a fast frequency sweep based on the Asymptotic Wave Expansion (AWE) method is developed and applied to generalized mixed circuit-EM problems. The AWE method, which was originally developed for lumped-load circuit simulations, has recently been shown to be effective at quasi-static and low frequency full-wave simulations. Here it is applied to a full-wave MoM solver, capable of solving for metals, dielectrics, and coupled circuit-EM problems.

  7. AVALIAÇÃO DA PRESENÇA DE ENDOSSIMBIONTES Cardinium em DIFERENTES ESPÉCIES DE ARTRÓPODES.

    Technology Transfer Automated Retrieval System (TEKTRAN)

    A presença de endossimbiontes do gênero Cardinium em alguns grupos de artrópodes foi recentemente relatada e relacionada com diversas alterações reprodutivas em seus hospedeiros, tais como feminilização de ácaros, partenogênese em parasitóides, incompatibilidade citoplasmática e aumento da fecundida...

  8. Aristarchus's <em>On the Sizes and Distances of the Sun and the Moonem>: Greek and Arabic Texts

    NASA Astrophysics Data System (ADS)

    Berggren, J. L.; Sidoli, N.

    2007-05-01

    In the 1920s, T. L. Heath pointed out that historians of mathematics have "given too little attention to Aristarchus". This is still true today. The Greek text of Aristarchus's On the Sizes and Distances of the Sun and the Moonem> has received little attention; the Arabic editions virtually none. Much of what this text has to tell us about ancient and medieval mathematics and the mathematical sciences has gone unnoticed. It should be taken as an important source for our understanding of the mathematical sciences of the early Hellenistic period.

  9. The EM fields in the Solid Generated by a Fault in a Porous Region

    NASA Astrophysics Data System (ADS)

    Ren, H.; Huang, Q.; Chen, X.

    2015-12-01

    Electrokinetic effect, as one of the most possible generation mechanisms of the seismo-electromagnetic phenomenons associated with natural earthquakes, has interested many researchers. Besides, it is also considered as a potential tool for the water/oil exploration. Recently, we numerically investigated the electromagnetic (EM) fields due to the electrokinetic effect in mixed layered model. The mixed model comprises not only porous layers but also solid layers. We firstly tested a two-layer mixed model. The numerical results show that, in addition to the radiation EM fields, another kind of evanescent EM fields can be generated by the seismic waves arriving at the interface with incident angles greater the critical angle. The evanescent EM fields decay faster than the radiation EM fields when getting away from the interface. For the seismic frequency band, the evanescent EM fields in the solid are still measurable at a distance of, e.g., 2km to the interface. We then tested a eight-layer mixed model. The top and bottom layers are solid and the other layers are porous. A finite fault of 20x10km is located in the porous region. The focal depth is 8km. The applied source time function is a ramp fuction with an arise time of 0.8s. Point stacking method was used to compute the wave-fields caused by the finite fault. Our nuemrical results show that, this model can generate the EM fields before the arrival of seismic waves as well as the residual EM fields. Both the two kinds of EM fields have been observed in field observations. There is a possibility that the anomalous EM activities before big earthquakes may be caused by the fluid flow in the shallow Earth as a result of the stress changes.

  10. Review of selected oceanic EM/EO scattering problems

    NASA Astrophysics Data System (ADS)

    Haller, Merrick C.

    2010-02-01

    Electromagnetic and electro-optical (EM/EO) propagation and scattering in the ocean is of interest for a wide range of science problems. For example, the biological productivity of ocean waters through photochemical processes is governed by the vertical attenuation of solar radiation. Also, EO scattering theory is the primary basis for determining biogeochemical parameters (e.g. phytoplankton, suspended sediments, and dissolved matter) from the water leaving optical radiance. In addition, EO scattering from suspended sediments and bubbles is the limiting factor for active lidar systems used to map the sea bottom. This work will review specific applications of EO/EM scattering theory with regard to the influence of bubbles and droplets on remote sensing in the nearshore ocean. The current state of understanding concerning models and applications for optical scattering from bubbles in the water column as well as microwave scattering from water droplets produced by breaking waves at the ocean surface will be discussed as well as future research directions.

  11. The Search for Gravitational Wave EM Counterparts with Swift

    NASA Astrophysics Data System (ADS)

    Kennea, Jamie; Evans, Phil; Swift GW follow-up Team

    2016-04-01

    We present the plan to search for electromagnetic counterparts of Gravitational Waves (GWs) discovered during the current and upcoming runs of the LIGO and Virgo detectors. As we enter a period where the sensitivity of the current generation of GW detectors approaches a high probability of the first detection of a real GW signal, confirmation of the reality of these triggers will be greatly improved if an EM counterpart can be found. Swift’s ability to rapidly respond to high priority target-of-opportunity observations, it’s multi-wavelength capabilities and low overhead observing make it a seemingly ideal follow-up facility. However comparing the size of the expected GW error regions with the fields of view of the Swift XRT and UVOT telescopes, we find that covering the large GW error regions would require a unreasonably large number of pointings. We present our method of meeting this challenge, by both reducing the problem using Galaxy targeting, and by operating Swift in an entirely new way in order to cover the still large number of fields needed to chase down the EM counterpart before it disappears.

  12. Chapter 19: HVAC Controls (DDC/EMS/BAS) Evaluation Protocol

    SciTech Connect

    Romberger, J.

    2014-11-01

    The HVAC Controls Evaluation Protocol is designed to address evaluation issues for direct digital controls/energy management systems/building automation systems (DDC/EMS/BAS) that are installed to control heating, ventilation, and air-conditioning (HVAC) equipment in commercial and institutional buildings. (This chapter refers to the DDC/EMS/BAS measure as HVAC controls.) This protocol may also be applicable to industrial facilities such as clean rooms and labs, which have either significant HVAC equipment or spaces requiring special environmental conditions. This protocol addresses only HVAC-related equipment and the energy savings estimation methods associated with installing such control systems as an energy efficiency measure. The affected equipment includes: Air-side equipment (air handlers, direct expansion systems, furnaces, other heating- and cooling-related devices, terminal air distribution equipment, and fans); Central plant equipment (chillers, cooling towers, boilers, and pumps). These controls may also operate or affect other end uses, such as lighting, domestic hot water, irrigation systems, and life safety systems such as fire alarms and other security systems. Considerable nonenergy benefits, such as maintenance scheduling, system component troubleshooting, equipment failure alarms, and increased equipment lifetime, may also be associated with these systems. When connected to building utility meters, these systems can also be valuable demand-limiting control tools. However, this protocol does not evaluate any of these additional capabilities and benefits.

  13. Contactless ultrasonic treatment of melts using EM induction

    NASA Astrophysics Data System (ADS)

    Bojarevics, V.; Djambazov, G.; Lebon, G. S. B.; Pericleous, K. A.

    2015-06-01

    Ultrasound Treatment (UT) is commonly used in light alloys during solidification to refine microstructure, or disperse immersed particles. A sonotrode probe introduced into the melt generates sound waves that are strong enough to produce cavitation of dissolved gases. The same method cannot be used in high temperature melts, or for highly reactive alloys, due to probe erosion and melt contamination. An alternative, contactless method of generating sound waves is proposed and investigated theoretically in this paper, using electromagnetic (EM) induction. In addition to strong vibration, the EM induction currents generate strong stirring in the melt that aids distribution of the UT effect to large volumes of material. In a typical application, the same induction coil surrounding the crucible used to melt the alloy may be adopted for UT with suitable frequency tuning. Alternatively - or in addition - a top coil may be used. For industrial use, instead of multiple sonotrodes as has been the practice in scaling up, modelling shows that one simply has to alter the coil geometry and current to suit. To reach sinusoidal pressure fluctuations suitable for cavitation it may be necessary to tune the induction coil frequency for resonance, given the crucible dimensions.

  14. Estudo em microondas do aprisionamento e precipitação de elétrons em explosões solares

    NASA Astrophysics Data System (ADS)

    Rosal, A. C.; Costa, J. E. R.

    2003-08-01

    Uma explosão solar é uma variação rápida e intensa do brilho que ocorre nas chamadas regiões ativas da atmosfera, constituídas por um plasma magnetizado com intensa indução magnética. Os modelos de explosões solares atuais, discutidos na literatura, apresentam características de aprisionamento e precipitação de elétrons em ambientes magnéticos simplificados. Neste trabalho, nos propusemos a separar a emissão dos elétrons aprisionados da emissão dos elétrons em precipitação apenas a partir da emissão em microondas, melhorando portanto o controle sobre o conjunto de parâmetros inferidos. A emissão em microondas da população em precipitação é bastante fraca e portanto da nossa base de dados de 130 explosões observadas pelo Rádio Polarímetro de Nobeyama, em sete freqüências, apenas para 32 foi possível separar as duas componentes de emissão com uma boa razão sinal/ruído. A partir de estudos das escalas de tempo das emissões devidas à variação gradual da emissão no aprisionamento e da variação rápida da emissão dos elétrons em precipitação foi possível obter a separação utilizando um filtro temporal nas emissões resultantes. Em nossa análise destas explosões estudamos os espectros girossincrotrônicos da emissão gradual, a qual associamos provir do topo dos arcos magnéticos e da emissão de variação rápida associada aos elétrons em precipitação. Estes espectros foram calculados e dos quais inferimos que a indução magnética efetiva do topo e dos pés foi em média, Btopo = 236 G e Bpés = 577 G, inferidas das freqüências de pico dos espectros em ntopo = 11,8 GHz e npés = 14,6 GHz com leve anisotropia (pequeno alargamento espectral). O índice espectral da distribuição não-térmica de elétrons d, inferido do índice espectral de fótons da emissão em regime opticamente fino, foi de dtopo = 3,3 e dpés = 3,9. Estes parâmetros são típicos da maioria das análises realizadas em ambiente único de

  15. Reference Linking with DOIs: A Case Study [and] The Santa Fe Convention of the Open Archives Initiative [and] The UPS Prototype: An Experiment End-User Service across E-Print Archives [and] The Costs of Print, Fiche, and Digital Access: The Early Canadiana Online Project [and] Ad*Access: Seeking Copyright Permissions for a Digital Age.

    ERIC Educational Resources Information Center

    Atkins, Helen; Lyons, Catherine; Ratner, Howard; Risher, Carol; Shillum, Chris; Sidman, David; Stevens, Andrew; Van de Sompel, Herbert; Lagoze, Carl; Van de Sompel, Herbert; Krichel, Thomas; Nelson, Michael L.; Hochstenbach, Patrick; Lyapunov, Victor M.; Maly, Kurt; Zubair, Mohammad; Kholief, Mohamed; Liu, Xiaoming; O'Connell, Heath; Kingma, Bruce R.; Pritcher, Lynn

    2000-01-01

    Includes five articles that discuss publishers' metadata hyperlinks with Digital Object Identifiers (DOIs) on the Internet; the Santa Fe Convention of the Open Archives initiative (Oai) that promotes author self-archiving; the Universal Preprint Service; costs of digital, microfiche, and print access; and an online database of old print…

  16. DOI: Current Status and Outlook [and] The Virtual Naval Hospital: Lessons Learned in Creating and Operating a Digital Health Sciences Library for Nomadic Patrons [and] Interoperability for Digital Objects and Repositories: The Cornell/CNRI Experiments [and] Education for Digital Libraries.

    ERIC Educational Resources Information Center

    Paskin, Norman; D'Alessandro, Michael P.; D'Alessandro, Donna M.; Hendrix, Mary J. C.; Bakalar, Richard S.; Ashley, Denis E.; Payette, Dandra; Blanchi, Christophe; Lagoze, Carl; Overly, Edward A.; Spink, Amanda

    1999-01-01

    Describes the origin of the DOI (Digital Object Identifier) as a persistent identifier for managing copyrighted materials and its development; creation of the U.S. Navy digital health sciences library for isolated primary care providers and their patients; Cornell and CNRI prototype architecture for interoperable digital objects and repositories;…

  17. The EM SSAB Annual Work Plan Process: Focusing Board Efforts and Resources - 13667

    SciTech Connect

    Young, Ralph

    2013-07-01

    One of the most daunting tasks for any new member of a local board of the Environmental Management Site Specific Advisory Board (EM SSAB) is to try to understand the scope of the clean-up activities going on at the site. In most cases, there are at least two or three major cleanup activities in progress as well as monitoring of past projects. When planning for future projects is added to the mix, the list of projects can be long. With the clean-up activities involving all major environmental media - air, water, soils, and groundwater, new EM SSAB members can find themselves totally overwhelmed and ineffective. Helping new members get over this initial hurdle is a major objective of EM and all local boards of the EM SSAB. Even as members start to understand the size and scope of the projects at a site, they can still be frustrated at the length of time it takes to see results and get projects completed. Many project and clean-up timelines for most of the sites go beyond 10 years, so it's not unusual for an EM SSAB member to see the completion of only 1 or 2 projects over the course of their 6-year term on the board. This paper explores the annual work planning process of the EM SSAB local boards, one tool that can be used to educate EM SSAB members into seeing the broader picture for the site. EM SSAB local work plans divide the site into projects focused on a specific environmental issue or media such as groundwater and/or waste disposal options. Projects are further broken down into smaller segments by highlighting major milestones. Using these metrics, local boards of the EM SSAB can start to quantify the effectiveness of the project in achieving the ultimate goal of site clean-up. These metrics can also trigger board advice and recommendations for EM. At the beginning of each fiscal year, the EM SSAB work plan provides a road map with quantifiable checkpoints for activities throughout the year. When the work plans are integrated with site-specific, enforceable

  18. Linear array implementation of the EM algorithm for PET image reconstruction

    SciTech Connect

    Rajan, K.; Patnaik, L.M.; Ramakrishna, J.

    1995-08-01

    The PET image reconstruction based on the EM algorithm has several attractive advantages over the conventional convolution back projection algorithms. However, the PET image reconstruction based on the EM algorithm is computationally burdensome for today`s single processor systems. In addition, a large memory is required for the storage of the image, projection data, and the probability matrix. Since the computations are easily divided into tasks executable in parallel, multiprocessor configurations are the ideal choice for fast execution of the EM algorithms. In tis study, the authors attempt to overcome these two problems by parallelizing the EM algorithm on a multiprocessor systems. The parallel EM algorithm on a linear array topology using the commercially available fast floating point digital signal processor (DSP) chips as the processing elements (PE`s) has been implemented. The performance of the EM algorithm on a 386/387 machine, IBM 6000 RISC workstation, and on the linear array system is discussed and compared. The results show that the computational speed performance of a linear array using 8 DSP chips as PE`s executing the EM image reconstruction algorithm is about 15.5 times better than that of the IBM 6000 RISC workstation. The novelty of the scheme is its simplicity. The linear array topology is expandable with a larger number of PE`s. The architecture is not dependant on the DSP chip chosen, and the substitution of the latest DSP chip is straightforward and could yield better speed performance.

  19. A new method for vitrifying samples for cryoEM.

    PubMed

    Razinkov, Ivan; Dandey, Venkata P; Wei, Hui; Zhang, Zhening; Melnekoff, David; Rice, William J; Wigge, Christoph; Potter, Clinton S; Carragher, Bridget

    2016-08-01

    Almost every aspect of cryo electron microscopy (cryoEM) has been automated over the last few decades. One of the challenges that remains to be addressed is the robust and reliable preparation of vitrified specimens of suitable ice thickness. We present results from a new device for preparing vitrified samples. The successful use of the device is coupled to a new "self-blotting" grid that we have developed to provide a method for spreading a sample to a thin film without the use of externally applied filter paper. This new approach has the advantage of using small amounts of protein material, resulting in large areas of ice of a well defined thickness containing evenly distributed single particles. We believe that these methods will in the future result in a system for vitrifying grids that is completely automated. PMID:27288865

  20. Speech articulator measurements using low power EM-wave sensors

    SciTech Connect

    Holzrichter, J.F.; Burnett, G.C.; Ng, L.C.; Lea, W.A.

    1998-01-01

    Very low power electromagnetic (EM) wave sensors are being used to measure speech articulator motions as speech is produced. Glottal tissue oscillations, jaw, tongue, soft palate, and other organs have been measured. Previously, microwave imaging (e.g., using radar sensors) appears not to have been considered for such monitoring. Glottal tissue movements detected by radar sensors correlate well with those obtained by established laboratory techniques, and have been used to estimate a voiced excitation function for speech processing applications. The noninvasive access, coupled with the small size, low power, and high resolution of these new sensors, permit promising research and development applications in speech production, communication disorders, speech recognition and related topics. {copyright} {ital 1998 Acoustical Society of America.}

  1. EM Properties of Magnetic Minerals at RADAR Frequencies

    NASA Technical Reports Server (NTRS)

    Stillman, D. E.; Olhoeft, G. R.

    2005-01-01

    Previous missions to Mars have revealed that Mars surface is magnetic at DC frequency. Does this highly magnetic surface layer attenuate RADAR energy as it does in certain locations on Earth? It has been suggested that the active magnetic mineral on Mars is titanomaghemite and/or titanomagnetite. When titanium is incorporated into a maghemite or magnetite crystal, the Curie temperature can be significantly reduced. Mars has a wide range of daily temperature fluctuations (303K - 143K), which could allow for daily passes through the Curie temperature. Hence, the global dust layer on Mars could experience widely varying magnetic properties as a function of temperature, more specifically being ferromagnetic at night and paramagnetic during the day. Measurements of EM properties of magnetic minerals were made versus frequency and temperature (300K- 180K). Magnetic minerals and Martian analog samples were gathered from a number of different locations on Earth.

  2. Balloting motion of SLEKE launch packages in EM railguns

    NASA Astrophysics Data System (ADS)

    Chu, Szu H.

    1993-01-01

    This paper reports some balloting motion computational results of the SLEKE (Sabot Launched Electric-gun Kinetic Energy) launch packages, which are in their early stage of development. The computation model considers the effects of the EM (Lorentz) propulsion force, friction, air resistance, gravity, elastic forces, and clearance between the launch package and the barrel. The axial, normal and yaw displacement, velocity and acceleration; friction; deformations and forces at the interfacing points are computed. The results of this study indicate that the balloting force for SLEKE launch packages is on the order of the air drag force and that a uniformly distributed power source would be more desirable than sharp pulse current for electromagnetic railguns.

  3. Detection of karst structures using airborne EM and VLF

    SciTech Connect

    Beard, L.P. Nyquist, J.E.; Carpenter, P.J.

    1994-12-31

    Through the combined use of multi-frequency helicopter electromagnetic and VLF data, it is possible to detect and delineate a wide variety of karst structures and possibly to assess their interconnectedness. Multi-frequency EM Can detect karst features if some element of the structure is conductive. This conductive aspect may derive from thick, moist soils in the depression commonly associated with a doline, from conductive fluids in the cavity, or from conductive sediments in the cavity if these occupy a significant portion of it. Multiple loop configurations may also increase the likelihood of detecting karst features. Preliminary evidence indicates total field VLF measurements may be able to detect interconnected karst pathways, so long as the pathways are water or sediment filled. Neither technique can effectively detect dry, resistive air-filled cavities.

  4. Integrated EM & Thermal Simulations with Upgraded VORPAL Software

    SciTech Connect

    D.N. Smithe, D. Karipides, P. Stoltz, G. Cheng, H. Wang

    2011-03-01

    Nuclear physics accelerators are powered by microwaves which must travel in waveguides between room-temperature sources and the cryogenic accelerator structures. The ohmic heat load from the microwaves is affected by the temperature-dependent surface resistance and in turn affects the cryogenic thermal conduction problem. Integrated EM & thermal analysis of this difficult non-linear problem is now possible with the VORPAL finite-difference time-domain simulation tool. We highlight thermal benchmarking work with a complex HOM feed-through geometry, done in collaboration with researchers at the Thomas Jefferson National Accelerator Laboratory, and discuss upcoming design studies with this emerging tool. This work is part of an effort to generalize the VORPAL framework to include generalized PDE capabilities, for wider multi-physics capabilities in the accelerator, vacuum electronics, plasma processing and fusion R&D fields, and we will also discuss user interface and algorithmic upgrades which facilitate this emerging multiphysics capability.

  5. Selling management on the cost benefits of EMS programs

    SciTech Connect

    Beck, W.B.

    1999-07-01

    One of the persistent misconceptions by management is that environmental programs are always a cost to the business. Management tolerates this situation because they recognize the legal and other ethical considerations related to environmental programs, however, they still regard them as a cost and a necessary evil. This paper will present several ideas that can be put into practice by the environmental professionals to counter this management perception. These include the identification and use of macro scale and micro scale cost considerations in the environmental balance sheet to provide management with a different and perhaps more realistic view of the worth of the program. This cost accounting approach should be viewed as just one of the several systems that should make up the modern day environmental management systems (EMS) program.

  6. Making connections. Voice and data solutions for EMS.

    PubMed

    Careless, James; Erich, John

    2008-08-01

    Communications used to be so simple-1) grab the radio, 2) push and talk. Now we're besieged by a confusing assortment of technology and terms-wideband, broadband, VoIP, RoIP, ect.- and a constand thrumming imperative to achieve and improve and perfect some mystical state of full interoperability. Frankly, it can all be a bit much. With this supplement, we hope to clarify you options. We examine the importance of broadband for EMS, with its potential for larger data "pipes" between the hospital and the field; advances in the promising technologies of Voice over IP and Radio over IP; and how some systems are improving their interconnectedness and resulting operations. The jargon can be overwhelming, but the ideas are worth understanding. PMID:18814746

  7. EM modeling of RF drive in DTL tank 4

    SciTech Connect

    Kurennoy, Sergey S.

    2012-06-19

    A 3-D MicroWave Studio model for the RF drive in the LANSCE DTL tank 4 has been built. Both eigensolver and time-domain modeling are used to evaluate maximal fields in the drive module and RF coupling. The LANSCE DTL tank 4 has recently been experiencing RF problems, which may or may not be related to its replaced RF coupler. This situation stimulated a request by Dan Rees to provide EM modeling of the RF drive in the DTL tank 4 (T4). Jim O'Hara provided a CAD model that was imported into the CST Microwave Studio (MWS) and after some modifications became a part of a simplified MWS model of the T4 RF drive. This technical note describes the model and presents simulation results.

  8. TrakEM2 Software for Neural Circuit Reconstruction

    PubMed Central

    Cardona, Albert; Saalfeld, Stephan; Schindelin, Johannes; Arganda-Carreras, Ignacio; Preibisch, Stephan; Longair, Mark; Tomancak, Pavel; Hartenstein, Volker; Douglas, Rodney J.

    2012-01-01

    A key challenge in neuroscience is the expeditious reconstruction of neuronal circuits. For model systems such as Drosophila and C. elegans, the limiting step is no longer the acquisition of imagery but the extraction of the circuit from images. For this purpose, we designed a software application, TrakEM2, that addresses the systematic reconstruction of neuronal circuits from large electron microscopical and optical image volumes. We address the challenges of image volume composition from individual, deformed images; of the reconstruction of neuronal arbors and annotation of synapses with fast manual and semi-automatic methods; and the management of large collections of both images and annotations. The output is a neural circuit of 3d arbors and synapses, encoded in NeuroML and other formats, ready for analysis. PMID:22723842

  9. TrakEM2 software for neural circuit reconstruction.

    PubMed

    Cardona, Albert; Saalfeld, Stephan; Schindelin, Johannes; Arganda-Carreras, Ignacio; Preibisch, Stephan; Longair, Mark; Tomancak, Pavel; Hartenstein, Volker; Douglas, Rodney J

    2012-01-01

    A key challenge in neuroscience is the expeditious reconstruction of neuronal circuits. For model systems such as Drosophila and C. elegans, the limiting step is no longer the acquisition of imagery but the extraction of the circuit from images. For this purpose, we designed a software application, TrakEM2, that addresses the systematic reconstruction of neuronal circuits from large electron microscopical and optical image volumes. We address the challenges of image volume composition from individual, deformed images; of the reconstruction of neuronal arbors and annotation of synapses with fast manual and semi-automatic methods; and the management of large collections of both images and annotations. The output is a neural circuit of 3d arbors and synapses, encoded in NeuroML and other formats, ready for analysis. PMID:22723842

  10. Kaisen. EMS as theater of the streets. Part two.

    PubMed

    Dernocoeur, K; Taigman, M

    1991-03-01

    Passing an EMT or paramedic course is a considerable achievement, as you have had to acquire a huge and fascinating volume of medical knowledge. But, did the program teach you acting skills? Acting? Whoever said that EMS professionals need to know anything about acting? We submit that you do; prehospital workers can gain many unanticipated benefits by using various acting skills and tactics in the field. One such benefit is the avoidance of the "complacency trap," or the boredom that can develop if you adopt the viewpoint that one crisis is much like another. But, more importantly, you will be more effective at delivering prehospital care, and you'll have a lot more fun on the job. PMID:10110186

  11. Suspended-Patch Antenna With Inverted, EM-Coupled Feed

    NASA Technical Reports Server (NTRS)

    Simons, Rainee N.

    2004-01-01

    An improved suspended-patch antenna has been designed to operate at a frequency of about 23 GHz with linear polarization and to be one of four identical antennas in a rectangular array. The antenna includes a parasitic patch on top of a suspended dielectric superstrate, an active patch on top of a suspended dielectric substrate, a microstrip on the bottom of the dielectric substrate, and a ground plane. The microstrip, the ground plane, the airgap between them, and the dielectric substrate together constitute a transmission line that has an impedance of 50 Ohm and is electromagnetically (EM) coupled to the active patch. The parasitic patch is, in turn, excited by the active patch. The microstrip feed is characterized as inverted because the microstrip is on the bottom of the substrate, whereas microstrips are usually placed on the tops of dielectric substrates

  12. User's guide for the PWR LOCA analysis capability of the WRAP-EM system

    SciTech Connect

    Beranek, F; Gregory, M V

    1980-02-01

    The Water Reactor Analysis Package (WRAP) has been expanded to provide the capability to analyze loss-of-coolant accidents (LOCAs) in both pressurized water reactors (PWRs) and boiling water reactors (BWRs) by using evaluation models (EMs). The input specifications for modules in the WRAP-EM system are presented in this document along with the JOSHUA input templates. This document, along with the WRAP user's guide, provides a step-by-step procedure for setting up a PWR data base for the WRAP-EM system. 12 refs.

  13. Time-Lapse inversion of EM Tomography data for polymer-injected hydrocarbon reservoirs

    NASA Astrophysics Data System (ADS)

    Cheon, Seiwook; Park, Chanho; Nam, Myung Jin; Son, Jeong-Sul

    2015-04-01

    Polymer flooding is a method to increase the production of hydrocarbon reservoir by injecting polymer solution into the reservoir. For a study on the monitoring fluid variation within the reservoir, we first make analysis on seismic- and electromagnetic (EM)- tomography responses for seismic and electrical-resistivity rock physics models (RPMs) of the reservoir considering polymer fluid. Constructing RPMs are dependent on not only geologic characteristics of reservoir but also reservoir parameters such as fluid-type, fluid saturation, pressure and temperature. When making RPM for monitoring analysis, we assume the geology does not changes while reservoir parameters change to affect responses of seismic and EM tomography data. Specifically when constructing electrical-resistivity RPM, we consider three different types of hydrocarbon reservoirs, which are clean sand, shaly sand, sand-shale lamination, while considering two different types of waters (fresh water and salt water) to make 2wt% polymer solution. To compute time lapse EM and seismic tomography responses for corresponding RPMs of polymer-injected reservoirs, we used 2.5D finite element EM modeling algorithm and staggered-grid finite difference elastic modeling algorithm, respectively. Comparison between sensitivities of seismic and EM tomography to polymer injection confirms that EM tomography is more sensitivity to the polymer injection. For the evaluation of the potential of EM tomography to monitor polymer flooding, this study subsequently develops an efficient time-lapse EM tomography inversion algorithm based on the 2.5D EM tomography modeling. Using the inversion algorithm, we inverted the time-lapse EM tomography data to construct true resistivity models of polymer-injected reservoirs and analyze differences between them. From the time-lapse inversion results, we can observe the differences in time lapse responses between using fresh water and salt water have been decreased in the inverted time

  14. Integration of artificial intelligence applications in the EMS: Issues and solutions

    SciTech Connect

    Bann, J.; Irisarri, G.; Kirschen, D.; Miller, B.; Mokhtari, S.

    1996-02-01

    This paper discusses the issues which must be addressed when integrating Artificial Intelligence (AI) and, in particular, expert system applications in an Energy Management System (EMS) environment. It is argued that these issues can be resolved by creating an environment which supports all the interfaces between the Artificial Intelligence (AI) applications and the EMS. This environment should also be responsible for maintaining a model of the power system common to all the AI applications. Once this environment has been created, AI applications can be easily plugged into the EMS. The design of such an environment is described and case studies of its implementation are provided to illustrate its flexibility.

  15. Stochastic EM algorithm for nonlinear state estimation with model uncertainties

    NASA Astrophysics Data System (ADS)

    Zia, Amin; Kirubarajan, Thiagalingam; Reilly, James P.; Shirani, Shahram

    2004-01-01

    In most solutions to state estimation problems like, for example, target tracking, it is generally assumed that the state evolution and measurement models are known a priori. The model parameters include process and measurement matrices or functions as well as the corresponding noise statistics. However, there are situations where the model parameters are not known a priori or are known only partially (i.e., with some uncertainty). Moreover, there are situations where the measurement is biased. In these scenarios, standard estimation algorithms like the Kalman filter and the extended Kalman Filter (EKF), which assume perfect knowledge of the model parameters, are not accurate. In this paper, the problem with uncertain model parameters is considered as a special case of maximum likelihood estimation with incomplete-data, for which a standard solution called the expectation-maximization (EM) algorithm exists. In this paper a new extension to the EM algorithm is proposed to solve the more general problem of joint state estimation and model parameter identification for nonlinear systems with possibly non-Gaussian noise. In the expectation (E) step, it is shown that the best variational distribution over the state variables is the conditional posterior distribution of states given all the available measurements and inputs. Therefore, a particular type of particle filter is used to estimate and update the posterior distribution. In the maximization (M) step the nonlinear measurement process parameters are approximated using a nonlinear regression method for adjusting the parameters of a mixture of Gaussians (MofG). The proposed algorithm is used to solve a nonlinear bearing-only tracking problem similar to the one reported recently with uncertain measurement process. It is shown that the algorithm is capable of accurately tracking the state vector while identifying the unknown measurement dynamics. Simulation results show the advantages of the new technique over standard

  16. Stochastic EM algorithm for nonlinear state estimation with model uncertainties

    NASA Astrophysics Data System (ADS)

    Zia, Amin; Kirubarajan, Thiagalingam; Reilly, James P.; Shirani, Shahram

    2003-12-01

    In most solutions to state estimation problems like, for example, target tracking, it is generally assumed that the state evolution and measurement models are known a priori. The model parameters include process and measurement matrices or functions as well as the corresponding noise statistics. However, there are situations where the model parameters are not known a priori or are known only partially (i.e., with some uncertainty). Moreover, there are situations where the measurement is biased. In these scenarios, standard estimation algorithms like the Kalman filter and the extended Kalman Filter (EKF), which assume perfect knowledge of the model parameters, are not accurate. In this paper, the problem with uncertain model parameters is considered as a special case of maximum likelihood estimation with incomplete-data, for which a standard solution called the expectation-maximization (EM) algorithm exists. In this paper a new extension to the EM algorithm is proposed to solve the more general problem of joint state estimation and model parameter identification for nonlinear systems with possibly non-Gaussian noise. In the expectation (E) step, it is shown that the best variational distribution over the state variables is the conditional posterior distribution of states given all the available measurements and inputs. Therefore, a particular type of particle filter is used to estimate and update the posterior distribution. In the maximization (M) step the nonlinear measurement process parameters are approximated using a nonlinear regression method for adjusting the parameters of a mixture of Gaussians (MofG). The proposed algorithm is used to solve a nonlinear bearing-only tracking problem similar to the one reported recently with uncertain measurement process. It is shown that the algorithm is capable of accurately tracking the state vector while identifying the unknown measurement dynamics. Simulation results show the advantages of the new technique over standard

  17. DOE-EM-45 PACKAGING OPERATIONS AND MAINTENANCE COURSE

    SciTech Connect

    Watkins, R.; England, J.

    2010-05-28

    Savannah River National Laboratory - Savannah River Packaging Technology (SRNL-SRPT) delivered the inaugural offering of the Packaging Operations and Maintenance Course for DOE-EM-45's Packaging Certification Program (PCP) at the University of South Carolina Aiken on September 1 and 2, 2009. Twenty-nine students registered, attended, and completed this training. The DOE-EM-45 Packaging Certification Program (PCP) sponsored the presentation of a new training course, Packaging Maintenance and Operations, on September 1-2, 2009 at the University of South Carolina Aiken (USC-Aiken) campus in Aiken, SC. The premier offering of the course was developed and presented by the Savannah River National Laboratory, and attended by twenty-nine students across the DOE, NNSA and private industry. This training informed package users of the requirements associated with handling shipping containers at a facility (user) level and provided a basic overview of the requirements typically outlined in Safety Analysis Report for Packaging (SARP) Chapters 1, 7, and 8. The course taught packaging personnel about the regulatory nature of SARPs to help reduce associated and often costly packaging errors. Some of the topics covered were package contents, loading, unloading, storage, torque requirements, maintaining records, how to handle abnormal conditions, lessons learned, leakage testing (including demonstration), and replacement parts. The target audience for this course was facility operations personnel, facility maintenance personnel, and field quality assurance personnel who are directly involved in the handling of shipping containers. The training also aimed at writers of SARP Chapters 1, 7, and 8, package designers, and anyone else involved in radioactive material packaging and transportation safety. Student feedback and critiques of the training were very positive. SRNL will offer the course again at USC Aiken in September 2010.

  18. Reply to the 'Comment on "Exposure to mercury and Aroclor 1268 congeners in least terns (Sternula antillarum) in coastal Georgia, USA"' by P. C. Fuchsman, M. H. Henning and V. S. Magar, Environmental Science: Processes & Impacts, 2016, 18, DOI: 10.1039/C5EM00489F.

    PubMed

    Robinson, Gabrielle L; Mills, Gary L; Schweitzer, Sara; Hernandez, Sonia

    2016-02-17

    This article provides our response to the comment by Fuchsman et al. regarding the interpretation of results presented in our recent publication (Robinson et al., Environmental Science: Processes & Impacts, 2015, 17, 1424) reporting on concentrations of Aroclor 1268 congeners in least tern eggs in coastal Georgia, USA. PMID:26814679

  19. Cryo-EM single particle analysis with the Volta phase plate

    PubMed Central

    Danev, Radostin; Baumeister, Wolfgang

    2016-01-01

    We present a method for in-focus data acquisition with a phase plate that enables near-atomic resolution single particle reconstructions. Accurate focusing is the determining factor for obtaining high quality data. A double-area focusing strategy was implemented in order to achieve the required precision. With this approach we obtained a 3.2 Å resolution reconstruction of the Thermoplasma acidophilum 20S proteasome. The phase plate matches or slightly exceeds the performance of the conventional defocus approach. Spherical aberration becomes a limiting factor for achieving resolutions below 3 Å with in-focus phase plate images. The phase plate could enable single particle analysis of challenging samples in terms of small size, heterogeneity and flexibility that are difficult to solve by the conventional defocus approach. DOI: http://dx.doi.org/10.7554/eLife.13046.001 PMID:26949259

  20. Vibrational symmetry classification and torsional tunneling splitting patterns in G6(EM), G12, and G36(EM) molecules

    NASA Astrophysics Data System (ADS)

    Lattanzi, F.; di Lauro, C.

    It is shown that the torsional splitting patterns in methanol-like molecules, with the excitation of small amplitude vibrational modes in the methyl group, are determined by mechanisms that can be formulated in an almost identical fashion to that for ethane-like molecules. This is achieved by treating ethane-like molecules by the internal axis method (IAM) and methanol-like molecules by the principal axis method (PAM) or rho-axis method (RAM). Using the extended molecular groups G6(EM) or C6v(M) for methanol and G36(EM) for ethane, vibrations perpendicular to the internal rotation axis are conveniently described by modes of higher degeneracy (E for methanol and Gs for ethane) in the absence of coupling of top and frame. Head-tail coupling operators, except the cos-type barrier terms, lower the degeneracy, causing vibrational splittings. Coupled vibrational pairs with torsional splitting patterns that we call 'regular' (pure A1, A2 pairs for methanol and pure E1d, E2d pairs for ethane) or 'inverted' (pure B1, B2 pairs for methanol and pure E1s, E2s pairs for ethane) can be formed as limit cases. Actual splitting patterns occur between the above limits, and are basically determined by torsional Coriolis coupling, which can tune more or less to resonance pairs of uncoupled basis levels linked by specific head-tail coupling operators. The inversion of torsional splitting patterns, observed in perpendicular vibrational modes of the methyl group of methanol, can be predicted by these theoretical considerations. Similar considerations apply to molecules of G12 symmetry.

  1. Aquisição de Estreptococos Mutans e Desenvolvimento de Cárie Dental em Primogênitos

    PubMed Central

    NOCE, Erica; RUBIRA, Cassia Maria Fischer; da Silva ROSA, Odila Pereira; da SILVA, Salete Moura Bonifácio; BRETZ, Walter Antonio

    2011-01-01

    Objetivo Avaliar o momento de aquisição de estreptococos mutans (EM), desenvolvimento de cárie dental e as variáveis a eles associadas no decorrer de 23 meses, em primogênitos de famílias de baixo nível socioeconômico, desde os sete meses de idade. Método A amostra foi selecionada com base em mães densamente colonizadas por EM, incluindo todos os membros de 14 famílias que conviviam na mesma casa. Foram envolvidos no estudo 14 mães, pais e primogênitos e 8 parentes, na maioria avós. Exames clínicos e radiográficos iniciais determinaram os índices de cárie e condição periodontal dos adultos. Contagens de EM foram feitas em todos os adultos nas duas primeiras visitas. Nas crianças foram avaliados os níveis de EM, o número de dentes e de cáries, em quatro visitas. Resultados A prevalência de EM nos adultos foi alta, estando ausente em apenas um dos pais. EM foram detectados em 1, 2, 3 e 10 crianças, respectivamente nas visitas #1, 2, 3 e 4. A cárie dental foi detectada em apenas três crianças na última visita (aos 30 meses de idade), as quais apresentaram escores de EM significantemente maiores que as crianças sem cárie, na mesma visita. Conclusão Exclusivamente a condição social de baixa renda e mães densamente colonizadas por EM não são sinônimo de colonização precoce e alta atividade de cárie em crianças cuidadas em casa. O desenvolvimento de cárie está significantemente associado a escores elevados de EM nas crianças. PMID:22022218

  2. EMDataBank.org: unified data resource for CryoEM

    PubMed Central

    Lawson, Catherine L.; Baker, Matthew L.; Best, Christoph; Bi, Chunxiao; Dougherty, Matthew; Feng, Powei; van Ginkel, Glen; Devkota, Batsal; Lagerstedt, Ingvar; Ludtke, Steven J.; Newman, Richard H.; Oldfield, Tom J.; Rees, Ian; Sahni, Gaurav; Sala, Raul; Velankar, Sameer; Warren, Joe; Westbrook, John D.; Henrick, Kim; Kleywegt, Gerard J.; Berman, Helen M.; Chiu, Wah

    2011-01-01

    Cryo-electron microscopy reconstruction methods are uniquely able to reveal structures of many important macromolecules and macromolecular complexes. EMDataBank.org, a joint effort of the Protein Data Bank in Europe (PDBe), the Research Collaboratory for Structural Bioinformatics (RCSB) and the National Center for Macromolecular Imaging (NCMI), is a global ‘one-stop shop’ resource for deposition and retrieval of cryoEM maps, models and associated metadata. The resource unifies public access to the two major archives containing EM-based structural data: EM Data Bank (EMDB) and Protein Data Bank (PDB), and facilitates use of EM structural data of macromolecules and macromolecular complexes by the wider scientific community. PMID:20935055

  3. Analysis of the electrochemistry of hemes with Ems spanning 800 mV

    PubMed Central

    Zheng, Zhong; Gunner, M. R.

    2009-01-01

    The free energy of heme reduction in different proteins is found to vary over more than 18 kcal/mol. It is a challenge to determine how proteins manage to achieve this enormous range of Ems with a single type of redox cofactor. Proteins containing 141 unique hemes of a-, b-, and c-type, with bis-His, His-Met, and aquo-His ligation were calculated using Multi-Conformation Continuum Electrostatics (MCCE). The experimental Ems range over 800 mV from −350 mV in cytochrome c3 to 450 mV in cytochrome c peroxidase (vs. SHE). The quantitative analysis of the factors that modulate heme electrochemistry includes the interactions of the heme with its ligands, the solvent, the protein backbone, and sidechains. MCCE calculated Ems are in good agreement with measured values. Using no free parameters the slope of the line comparing calculated and experimental Ems is 0.73 (R2 = 0.90), showing the method accounts for 73% of the observed Em range. Adding a +160 mV correction to the His-Met c-type hemes yields a slope of 0.97 (R2 = 0.93). With the correction 65% of the hemes have an absolute error smaller than 60 mV and 92% are within 120 mV. The overview of heme proteins with known structures and Ems shows both the lowest and highest potential hemes are c-type, whereas the b-type hemes are found in the middle Em range. In solution, bis-His ligation lowers the Em by ≈205 mV relative to hemes with His-Met ligands. The bis-His, aquo-His, and His-Met ligated b-type hemes all cluster about Ems which are ≈200 mV more positive in protein than in water. In contrast, the low potential bis-His c-type hemes are shifted little from in solution, whereas the high potential His-Met c-type hemes are raised by ≈300 mV from solution. The analysis shows that no single type of interaction can be identified as the most important in setting heme electrochemistry in proteins. For example, the loss of solvation (reaction field) energy, which raises the Em, has been suggested to be a major factor in

  4. Volta phase plate cryo-EM of the small protein complex Prx3

    PubMed Central

    Khoshouei, Maryam; Radjainia, Mazdak; Phillips, Amy J.; Gerrard, Juliet A.; Mitra, Alok K.; Plitzko, Jürgen M.; Baumeister, Wolfgang; Danev, Radostin

    2016-01-01

    Cryo-EM of large, macromolecular assemblies has seen a significant increase in the numbers of high-resolution structures since the arrival of direct electron detectors. However, sub-nanometre resolution cryo-EM structures are rare compared with crystal structure depositions, particularly for relatively small particles (<400 kDa). Here we demonstrate the benefits of Volta phase plates for single-particle analysis by time-efficient cryo-EM structure determination of 257 kDa human peroxiredoxin-3 dodecamers at 4.4 Å resolution. The Volta phase plate improves the applicability of cryo-EM for small molecules and accelerates structure determination. PMID:26817416

  5. 7. PHOTOCOPY, ELEVATIONS FOR E.M. BARRACKS, N.C.O. AND OFFICERS QUARTERS. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    7. PHOTOCOPY, ELEVATIONS FOR E.M. BARRACKS, N.C.O. AND OFFICERS QUARTERS. - NIKE Missile Base SL-40, Barracks No. 1, North end of base, southest of Basketball Court & northwest of Barracks No. 2, Hecker, Monroe County, IL

  6. The development of cryo-EM into a mainstream structural biology technique

    PubMed Central

    Nogales, Eva

    2016-01-01

    Single-particle cryo-electron microscopy (cryo-EM) has emerged over the last two decades as a technique capable of studying challenging systems that otherwise defy structural characterization. Recent technical advances have resulted in a ‘quantum leap’ in applicability, throughput and achievable resolution that has gained this technique worldwide attention. Here I discuss some of the major historical landmarks in the development of the cryo-EM field, ultimately leading to its present success. PMID:27110629

  7. The front lines of domestic violence. Training model for rural EMS personnel.

    PubMed

    Hall, Marcia; Becker, Vanessa

    2002-09-01

    1. Domestic violence is a major public health problem requiring committed, coordinated community response. 2. Domestic violence is a significant cause of morbidity and mortality for women and children in the United States. 3. EMS personnel play a frontline role in the critical response and prevention of domestic violence. 4. EMS education and training are requisite for safe, effective responses to domestic violence in rural communities. PMID:12235968

  8. Space resolution obtained with a highly segmented SCIFI e.m. calorimeter

    NASA Astrophysics Data System (ADS)

    Bertino, M.; Bini, C.; De Pedis, D.; De Zorzi, G.; Diambrini Palazzi, G.; Di Cosimo, G.; Di Domenico, A.; Gauzzi, P.; Zanello, D.

    1992-05-01

    During the setting up of the LEP-5 experiment, we tested a longitudinal SCIFI e.m. calorimeter, having a module cross area 25 × 25 mm 2 and 12.5 × 12.5 mm 2 for large and small modules respectively. The results were obtained with 10 and 50 GeV electrons, and concern the impact point resolution and the transverse distribution of the e.m. shower energy inside the calorimeter.

  9. Effects of Loaded Squat Exercise with and without Application of Superimposed EMS on Physical Performance.

    PubMed

    Wirtz, Nicolas; Zinner, Christoph; Doermann, Ulrike; Kleinoeder, Heinz; Mester, Joachim

    2016-03-01

    The aim of the present study was to investigate the effects of a multiple set squat exercise training intervention with superimposed electromyostimulation (EMS) on strength and power, sprint and jump performance. Twenty athletes from different disciplines participated and were divided into two groups: strength training (S) or strength training with superimposed EMS (S+E). Both groups completed the same training program twice a week over a six week period consisting of four sets of the 10 repetition maximum of back squats. Additionally, the S+E group had EMS superimposed to the squat exercise with simultaneous stimulation of leg and trunk muscles. EMS intensity was adjusted to 70% of individual pain threshold to ensure dynamic movement. Strength and power of different muscle groups, sprint, and vertical jump performance were assessed one week before (pre), one week after (post) and three weeks (re) following the training period. Both groups showed improvements in leg press strength and power, countermovement and squat jump performance and pendulum sprint (p < 0.05), with no changes for linear sprint. Differences between groups were only evident at the leg curl machine with greater improvements for the S+E group (p < 0.05). Common squat exercise training and squat exercise with superimposed EMS improves maximum strength and power, as well as jumping abilities in athletes from different disciplines. The greater improvements in strength performance of leg curl muscles caused by superimposed EMS with improvements in strength of antagonistic hamstrings in the S+E group are suggesting the potential of EMS to unloaded (antagonistic) muscle groups. Key pointsSimilar strength adaptations occurred after a 6 week 10 RM back squat exercise program with superimposed EMS (S+E) and 10 RM back squat exercise (S) alone.Specific adaptations for S+E at the leg curl muscles were evident.S and S+E improved SJ, CMJ and pendulum sprint performance.No improvement occurred in linear sprint

  10. Effects of Loaded Squat Exercise with and without Application of Superimposed EMS on Physical Performance

    PubMed Central

    Wirtz, Nicolas; Zinner, Christoph; Doermann, Ulrike; Kleinoeder, Heinz; Mester, Joachim

    2016-01-01

    The aim of the present study was to investigate the effects of a multiple set squat exercise training intervention with superimposed electromyostimulation (EMS) on strength and power, sprint and jump performance. Twenty athletes from different disciplines participated and were divided into two groups: strength training (S) or strength training with superimposed EMS (S+E). Both groups completed the same training program twice a week over a six week period consisting of four sets of the 10 repetition maximum of back squats. Additionally, the S+E group had EMS superimposed to the squat exercise with simultaneous stimulation of leg and trunk muscles. EMS intensity was adjusted to 70% of individual pain threshold to ensure dynamic movement. Strength and power of different muscle groups, sprint, and vertical jump performance were assessed one week before (pre), one week after (post) and three weeks (re) following the training period. Both groups showed improvements in leg press strength and power, countermovement and squat jump performance and pendulum sprint (p < 0.05), with no changes for linear sprint. Differences between groups were only evident at the leg curl machine with greater improvements for the S+E group (p < 0.05). Common squat exercise training and squat exercise with superimposed EMS improves maximum strength and power, as well as jumping abilities in athletes from different disciplines. The greater improvements in strength performance of leg curl muscles caused by superimposed EMS with improvements in strength of antagonistic hamstrings in the S+E group are suggesting the potential of EMS to unloaded (antagonistic) muscle groups. Key points Similar strength adaptations occurred after a 6 week 10 RM back squat exercise program with superimposed EMS (S+E) and 10 RM back squat exercise (S) alone. Specific adaptations for S+E at the leg curl muscles were evident. S and S+E improved SJ, CMJ and pendulum sprint performance. No improvement occurred in linear

  11. ModEM: A modular system for inversion of elecgtromagnetic geophysical data

    NASA Astrophysics Data System (ADS)

    Egbert, G. D.; Kelbert, A.; Meqbel, N.; Weng, A.

    2010-12-01

    We have developed a modular system of computer codes for inversion of electromagnetic (EM) geophysical data (ModEM). ModEM allows for rapid adaptation of inversion algorithms developed for one purpose (e.g., three-dimensional magnetotellurics (MT)) to other EM problems (e.g., controlled source EM). The modular approach can also simplify maintenance of the inversion code, as well as development of new capabilities -- e.g., allowing for new data types such as the inter-site transfer functions in MT, or modifying model regularization. Basic data objects (model parameters, solution vectors, data vectors) are treated as abstract data types, with a standard set of methods developed for each class, including creation and destruction, and, as appropriate, linear algebra or other vector space methods. Operators required for gradient computations are developed as mappings between these basic object classes. Only these abstract data objects and mappings are manipulated by higher level Jacobian and inversion routines, with no reference to the problem specific details required for a specific EM method, or for the numerical implementation of the forward solver. Required problem-specific components are instantiated at the lowest levels of the system, with details hidden from generic top-level routines by an interface layer. Parallelization using MPI has been implemented at the top level, and is thus applicable to any problem embedded in ModEM. To illustrate the flexibility of the system, we consider applications to two- and three-dimensional MT inversion, as well as simple controlled source EM problems.

  12. The Soils and Groundwater – EM-20 S&T Roadmap Quality Assurance Project Plan

    SciTech Connect

    Fix, N. J.

    2008-02-11

    The Soils and Groundwater – EM-20 Science and Technology Roadmap Project is a U.S. Department of Energy, Office of Environmental Management-funded initiative designed to develop new methods, strategies and technology for characterizing, modeling, remediating, and monitoring soils and groundwater contaminated with metals, radionuclides, and chlorinated organics. This Quality Assurance Project Plan provides the quality assurance requirements and processes that will be followed by EM-20 Roadmap Project staff.

  13. Pre-flight risk assessment in emergency medical service (EMS) helicopters

    NASA Technical Reports Server (NTRS)

    Shively, Robert J.

    1990-01-01

    A preflight risk assessment system (SAFE) was developed at NASA-Ames Research Center for civil EMS operations to assist pilots in making a decision objectively to accept or decline a mission. The ability of the SAFE system to predict risk profiles was examined at an EMS operator. Results of this field study showed that the usefulness of SAFE was largely dependent on the type of mission flown.

  14. Single-particle cryo-EM data acquisition by using direct electron detection camera.

    PubMed

    Wu, Shenping; Armache, Jean-Paul; Cheng, Yifan

    2016-02-01

    Recent advances in single-particle electron cryo-microscopy (cryo-EM) were largely facilitated by the application of direct electron detection cameras. These cameras feature not only a significant improvement in detective quantum efficiency but also a high frame rate that enables images to be acquired as 'movies' made of stacks of many frames. In this review, we discuss how the applications of direct electron detection cameras in cryo-EM have changed the way the data are acquired. PMID:26546989

  15. Using Molecular Simulation to Model High-Resolution Cryo-EM Reconstructions.

    PubMed

    Kirmizialtin, Serdal; Loerke, Justus; Behrmann, Elmar; Spahn, Christian M T; Sanbonmatsu, Karissa Y

    2015-01-01

    An explosion of new data from high-resolution cryo-electron microscopy (cryo-EM) studies has produced a large number of data sets for many species of ribosomes in various functional states over the past few years. While many methods exist to produce structural models for lower resolution cryo-EM reconstructions, high-resolution reconstructions are often modeled using crystallographic techniques and extensive manual intervention. Here, we present an automated fitting technique for high-resolution cryo-EM data sets that produces all-atom models highly consistent with the EM density. Using a molecular dynamics approach, atomic positions are optimized with a potential that includes the cross-correlation coefficient between the structural model and the cryo-EM electron density, as well as a biasing potential preserving the stereochemistry and secondary structure of the biomolecule. Specifically, we use a hybrid structure-based/ab initio molecular dynamics potential to extend molecular dynamics fitting. In addition, we find that simulated annealing integration, as opposed to straightforward molecular dynamics integration, significantly improves performance. We obtain atomistic models of the human ribosome consistent with high-resolution cryo-EM reconstructions of the human ribosome. Automated methods such as these have the potential to produce atomistic models for a large number of ribosome complexes simultaneously that can be subsequently refined manually. PMID:26068751

  16. Fusion to a homo-oligomeric scaffold allows cryo-EM analysis of a small protein.

    PubMed

    Coscia, Francesca; Estrozi, Leandro F; Hans, Fabienne; Malet, Hélène; Noirclerc-Savoye, Marjolaine; Schoehn, Guy; Petosa, Carlo

    2016-01-01

    Recent technical advances have revolutionized the field of cryo-electron microscopy (cryo-EM). However, most monomeric proteins remain too small (<100 kDa) for cryo-EM analysis. To overcome this limitation, we explored a strategy whereby a monomeric target protein is genetically fused to a homo-oligomeric scaffold protein and the junction optimized to allow the target to adopt the scaffold symmetry, thereby generating a chimeric particle suitable for cryo-EM. To demonstrate the concept, we fused maltose-binding protein (MBP), a 40 kDa monomer, to glutamine synthetase, a dodecamer formed by two hexameric rings. Chimeric constructs with different junction lengths were screened by biophysical analysis and negative-stain EM. The optimal construct yielded a cryo-EM reconstruction that revealed the MBP structure at sub-nanometre resolution. These findings illustrate the feasibility of using homo-oligomeric scaffolds to enable cryo-EM analysis of monomeric proteins, paving the way for applying this strategy to challenging structures resistant to crystallographic and NMR analysis. PMID:27485862

  17. New Developments in the Technology Readiness Assessment Process in US DOE-EM - 13247

    SciTech Connect

    Krahn, Steven; Sutter, Herbert; Johnson, Hoyt

    2013-07-01

    A Technology Readiness Assessment (TRA) is a systematic, metric-based process and accompanying report that evaluates the maturity of the technologies used in systems; it is designed to measure technology maturity using the Technology Readiness Level (TRL) scale pioneered by the National Aeronautics and Space Administration (NASA) in the 1980's. More recently, DoD has adopted and provided systematic guidance for performing TRAs and determining TRLs. In 2007 the GAO recommended that the DOE adopt the NASA/DoD methodology for evaluating technology maturity. Earlier, in 2006-2007, DOE-EM had conducted pilot TRAs on a number of projects at Hanford and Savannah River. In March 2008, DOE-EM issued a process guide, which established TRAs as an integral part of DOE-EM's Project Management Critical Decision Process. Since the development of its detailed TRA guidance in 2008, DOE-EM has continued to accumulate experience in the conduct of TRAs and the process for evaluating technology maturity. DOE has developed guidance on TRAs applicable department-wide. DOE-EM's experience with the TRA process, the evaluations that led to recently developed proposed revisions to the DOE-EM TRA/TMP Guide; the content of the proposed changes that incorporate the above lessons learned and insights are described. (authors)

  18. Visualizing Proteins and Macromolecular Complexes by Negative Stain EM: from Grid Preparation to Image Acquisition

    PubMed Central

    Booth, David S.; Avila-Sakar, Agustin; Cheng, Yifan

    2011-01-01

    Single particle electron microscopy (EM), of both negative stained or frozen hydrated biological samples, has become a versatile tool in structural biology 1. In recent years, this method has achieved great success in studying structures of proteins and macromolecular complexes 2, 3. Compared with electron cryomicroscopy (cryoEM), in which frozen hydrated protein samples are embedded in a thin layer of vitreous ice 4, negative staining is a simpler sample preparation method in which protein samples are embedded in a thin layer of dried heavy metal salt to increase specimen contrast 5. The enhanced contrast of negative stain EM allows examination of relatively small biological samples. In addition to determining three-dimensional (3D) structure of purified proteins or protein complexes 6, this method can be used for much broader purposes. For example, negative stain EM can be easily used to visualize purified protein samples, obtaining information such as homogeneity/heterogeneity of the sample, formation of protein complexes or large assemblies, or simply to evaluate the quality of a protein preparation. In this video article, we present a complete protocol for using an EM to observe negatively stained protein sample, from preparing carbon coated grids for negative stain EM to acquiring images of negatively stained sample in an electron microscope operated at 120kV accelerating voltage. These protocols have been used in our laboratory routinely and can be easily followed by novice users. PMID:22215030

  19. An erythromycin derivative, EM-523, induces motilin-like gastrointestinal motility in dogs.

    PubMed

    Inatomi, N; Satoh, H; Maki, Y; Hashimoto, N; Itoh, Z; Omura, S

    1989-11-01

    The effect of an erythromycin derivative, EM-523, on gastrointestinal motility was investigated in conscious dogs and compared with that of motilin cisapride, trimebutine and metoclopramide. In the fasting state, EM-523 given i.v. or i.d. at 3 micrograms/kg or more induced contractions in the stomach that migrated along the small intestine. The pattern of the contractions was very similar to that induced by motilin. In the digestive state, EM-523 increased the amplitude of gastric contractions. Cisapride and metoclopramide increased gastrointestinal motility both in the fasting and digestive states; however, their contractile pattern was different from that of EM-523. Trimebutine did not induce gastric motility in the fasting state but rather decreased gastric motility in the digestive state. The contractions induced by EM-523 and motilin were inhibited by atropine but were not affected by naloxone, suggesting that the cholinergic pathway is important in the exertion of their action. These results indicate that EM-523 mimics motilin in stimulating gastrointestinal motility and that this agent may be useful treat gastrointestinal disorders such as gastric stasis, gastroesophageal reflux, and postoperative ileus, and so forth. PMID:2810120

  20. Reservoir characterization and process monitoring with EM methods. 1994 Annual report

    SciTech Connect

    Wilt, M.

    1995-05-01

    During the past five years at Lawrence Livermore National Laboratory (LLNL) the authors have applied the EM induction method to the problem of petroleum reservoir characterization and enhanced oil recovery (EOR) monitoring. The goal is to develop practical tools for determining the electrical resistivity distribution between boreholes at a useful scale for reservoir characterization. During FY94 the authors conducted their largest field test to date. They applied crosshole and surface-to-borehole EM techniques to reservoir characterization at the Los Hills No. 3 oil field making three sets of measurements during the initial phase of the steam drive.From these data they were able to determine the resistivity and configuration of the oil sands, between the observation wells, and provide an image of the subsurface resistivity changes due to the steam drive. They also conducted a waterflood experiment at the Richmond Field Station facility using the borehole-to-surface EM technique. For this test they injected a small quantity of saltwater, and applied the Em technique to monitor the progress of the injected plume. Data collection for this experiment is complete but the results are yet to be interpreted. Finally, a project to understand EM propagation through steel casing was initiated in 1994. The goals of the experiment are to determine the limits and applications for crosswell EM surveys through steel well casing.

  1. An Uncertainty Analysis for Predicting Soil Profile Salinity Using EM Induction Data

    NASA Astrophysics Data System (ADS)

    Huang, Jingyi; Monteiro Santos, Fernando; Triantafilis, John

    2016-04-01

    Proximal soil sensing techniques such as electromagnetic (EM) induction have been used to identify and map the areal variation of average soil properties. However, soil varies with depth owing to the action of various soil forming factors (e.g., parent material and topography). In this work we collected EM data using an EM38 and EM34 meter along a 22-km transect in the Trangie District, Australia.We jointly inverted these data using EM4Soil software and compare our 2-dimensional model of true electrical conductivity (sigma - mS/m) with depth against measured electrical conductivity of a saturated soil-paste extract (ECe - dS/m) at depth of 0-16 m. Through the use of a linear regression (LR) model and by varying forward modelling algorithms (cumulative function and full solution), inversion algorithms (S1 and S2), and damping factor (lambda) we determined a suitable electromagnetic conductivity image (EMCI) which was optimal when using the full solution, S2 and lambda = 0.6. To evaluate uncertainty of the inversion process and the LR model, we conducted an uncertainty analysis. The distribution of the model misfit shows the largest uncertainty caused by inversion (mostly due to EM34-40) occurs at deeper profiles while the largest uncertainty of the LR model occurs where the soil profile is most saline. These uncertainty maps also illustrate us how the model accuracy can be improved in the future.

  2. Operation Protective Edge - A Unique Challenge for a Civilian EMS Agency.

    PubMed

    Jaffe, Eli; Strugo, Refael; Wacht, Oren

    2015-10-01

    During July through August 2014, Operation Protective Edge, a military conflict between Israel and the Hamas regime in Gaza, dramatically affected both populations. Magen David Adom (MDA), the Israeli national Emergency Medical Service (EMS) and a member of the Red Cross, faced a unique challenge during the conflict: to continue providing crucial service to the entire civilian population of Israel, which was under constant missile threat. This challenge included not only providing immediate care for routine EMS calls under missile threat, but also preparing and delivering immediate care to civilians injured in attacks on major cities, as well as small communities, in Israel. This task is a challenge for a civilian EMS agency that normally operates in a non-military environment, yet, in an instant, must enhance its capability to respond to a considerable threat to its population. During Operation Protective Edge, MDA provided care for 842 wounded civilians and utilized a significant amount of its resources. Providing EMS services for a civilian population in a mixed civilian/military scenario is a challenging task on a national level for an EMS system, especially when the threat lasts for weeks. This report describes MDA's preparedness and operations during Operation Protective Edge, and the unique EMS challenges and dilemmas the agency faced. PMID:26323985

  3. High-speed computation of the EM algorithm for PET image reconstruction

    SciTech Connect

    Rajan, K.; Patnaik, L.M.; Ramakrishna, J. )

    1994-10-01

    The PET image reconstruction based on the EM algorithm has several attractive advantages over the conventional convolution backprojection algorithms. However, two major drawbacks have impeded the routine use of the EM algorithm, namely, the long computational time due to slow convergence and the large memory required for the storage of the image, projection data and the probability matrix. In this study, the authors attempts to solve these two problems by parallelizing the EM algorithm on a multiprocessor system. The authors have implemented an extended hypercube (EH) architecture for the high-speed computation of the EM algorithm using the commercially available fast floating point digital signal processor (DSP) chips as the processing elements (PEs). The authors discuss and compare the performance of the EM algorithm on a 386/387 machine, CD 4360 mainframe, and on the EH system. The results show that the computational speed performance of an EH using DSP chips as PEs executing the EM image reconstruction algorithm is about 130 times better than that of the CD 4360 mainframe. The EH topology is expandable with more number of PEs.

  4. Fusion to a homo-oligomeric scaffold allows cryo-EM analysis of a small protein

    PubMed Central

    Coscia, Francesca; Estrozi, Leandro F.; Hans, Fabienne; Malet, Hélène; Noirclerc-Savoye, Marjolaine; Schoehn, Guy; Petosa, Carlo

    2016-01-01

    Recent technical advances have revolutionized the field of cryo-electron microscopy (cryo-EM). However, most monomeric proteins remain too small (<100 kDa) for cryo-EM analysis. To overcome this limitation, we explored a strategy whereby a monomeric target protein is genetically fused to a homo-oligomeric scaffold protein and the junction optimized to allow the target to adopt the scaffold symmetry, thereby generating a chimeric particle suitable for cryo-EM. To demonstrate the concept, we fused maltose-binding protein (MBP), a 40 kDa monomer, to glutamine synthetase, a dodecamer formed by two hexameric rings. Chimeric constructs with different junction lengths were screened by biophysical analysis and negative-stain EM. The optimal construct yielded a cryo-EM reconstruction that revealed the MBP structure at sub-nanometre resolution. These findings illustrate the feasibility of using homo-oligomeric scaffolds to enable cryo-EM analysis of monomeric proteins, paving the way for applying this strategy to challenging structures resistant to crystallographic and NMR analysis. PMID:27485862

  5. Method for estimating dynamic EM tracking accuracy of surgical navigation tools

    NASA Astrophysics Data System (ADS)

    Nafis, Christopher; Jensen, Vern; Beauregard, Lee; Anderson, Peter

    2006-03-01

    Optical tracking systems have been used for several years in image guided medical procedures. Vendors often state static accuracies of a single retro-reflective sphere or LED. Expensive coordinate measurement machines (CMM) are used to validate the positional accuracy over the specified working volume. Users are interested in the dynamic accuracy of their tools. The configuration of individual sensors into a unique tool, the calibration of the tool tip, and the motion of the tool contribute additional errors. Electromagnetic (EM) tracking systems are considered an enabling technology for many image guided procedures because they are not limited by line-of-sight restrictions, take minimum space in the operating room, and the sensors can be very small. It is often difficult to quantify the accuracy of EM trackers because they can be affected by field distortion from certain metal objects. Many high-accuracy measurement devices can affect the EM measurements being validated. EM Tracker accuracy tends to vary over the working volume and orientation of the sensors. We present several simple methods for estimating the dynamic accuracy of EM tracked tools. We discuss the characteristics of the EM Tracker used in the GE Healthcare family of surgical navigation systems. Results for other tracking systems are included.

  6. EM techniques for archaeological laboratory experiments: preliminary results

    NASA Astrophysics Data System (ADS)

    Capozzoli, Luigi; De Martino, Gregory; Giampaolo, Valeria; Raffaele, Luongo; Perciante, Felice; Rizzo, Enzo

    2015-04-01

    The electromagnetic techniques (EM) are based on the investigation of subsoil geophysical parameters and in the archaeological framework they involve in studying contrasts between the buried cultural structures and the surrounding materials. Unfortunately, the geophysical contrast between archaeological features and surrounding soils sometimes are difficult to define due to problems of sensitivity and resolution both related on the characteristic of the subsoil and the geophysical methods. For this reason an experimental activity has been performed in the Hydrogeosite laboratory addressed on the assessment of the capability of geophysical techniques to detect archeological remains placed in the humid/saturated subsoil. At Hydrogeosite Laboratory of CNR-IMAA, a large scale sand-box is located, consisting on a pool shape structures of 230m3 where archaeological remains have been installed . The remains are relative to a living environment and burial of Roman times (walls, tombs, roads, harbour, etc.) covered by sediments. In order to simulate lacustrine and wetland condition and to simulate extreme events (for example underwater landslide, fast natural erosion coast, etc.) the phreatic level was varied and various acquisitions for the different scenarios were performed. In order to analyze the EM behavior of the buried small archaeological framework, ground penetrating radar (GPR) and electrical resistivity tomographies were performed. With GPR, analysis in time domain and frequency domain were performed and coupled to information obtained through resistivity analysis with the support of numerical simulations used to compare the real data with those modeled. A dense grid was adopted for 400 and 900 MHz e-m acquisitions in both the directions, the maximum depth of investigation was limited and less than 3 meters. The same approach was used for ERT acquisition where different array are employed, in particular 3D configuration was used to carry out a 3D resistivity

  7. Tide-driven fluid mud transport in the Ems estuary

    NASA Astrophysics Data System (ADS)

    Becker, Marius; Maushake, Christian; Winter, Christian

    2014-05-01

    The Ems estuary, located at the border between The Netherlands and Germany, experienced a significant change of the hydrodynamic regime during the past decades, as a result of extensive river engineering. With the net sediment transport now being flood-oriented, suspended sediment concentrations have increased dramatically, inducing siltation and formation of fluid mud layers, which, in turn, influence hydraulic flow properties, such as turbulence and the apparent bed roughness. Here, the process-based understanding of fluid mud is essential to model and predict mud accumulation, not only regarding the anthropogenic impact, but also in view of the expected changes of environmental boundary conditions, i.e., sea level rise. In the recent past, substantial progress has been made concerning the understanding of estuarine circulation and influence of tidal asymmetry on upstream sediment accumulation. While associated sediment transport formulations have been implemented in the framework of numerical modelling systems, in-situ data of fluid mud are scarce. This study presents results on tide-driven fluid mud dynamics, measured during four tidal cycles aside the navigation channel in the Ems estuary. Lutoclines, i.e., strong vertical density gradients, were detected by sediment echo sounder (SES). Acoustic Doppler current profiles (ADCP) of different acoustic frequencies were used to determine hydrodynamic parameters and the vertical distribution of suspended sediment concentrations in the upper part of the water column. These continuous profiling measurements were complemented by CTD, ADV, and OBS casts. SES and ADCP profiles show cycles of fluid mud entrainment during accelerating flow, and subsequent settling, and the reformation of a lutocline during decelerating flow and slack water. Significant differences are revealed between flood and ebb phase. Highest entrainment rates are measured at the beginning of the flood phase, associated with strong current shear and

  8. Exploration Depth of Multi-frequency Helicopter EM Systems

    NASA Astrophysics Data System (ADS)

    Yin, C.; Hodges, G.

    2004-05-01

    Due to the high resolution of hilicopter electromagnetic (HEM) systems, they are being widely used for shallow earth resistivity mapping problems. The traditional investigation of the exploration depth of a HEM system is based on the model of a single-frequency coil array over a layered earth. In this paper we extend the study to the multi-frequency HEM systems. We first determine for each frequency channel of a HEM system the maximal depth of a target, beyond which it cannot be identified from the EM signal. This is mathemically realized by assuming that the abnormal signal from the target is three times larger than the noise level of the HEM channel. Since each frequency channel of an HEM system has a different noise level and for different frequency channel the EM field has different penetration depth, we choose the biggest value of these depths as the depth of exploration. Different models are implemented in the study of this paper, including a layered earth model, a dipping plate or a dyke, a 3D ore body, etc. We use as example the Fugro DIGHEM system with three horizontal coplanar (HCP) coils (380 or 900, 7200, 56kHz) and two vertical coaxial (VCX) coils (900, 5500Hz). The following conclusions are obtained: 1. Except for a steeply dipping sheet, the HCP coil array has a larger depth of exploration than the VCX coil array; 2. The depth of exploration may be obtained from different frequency channels for different target geometries and different conductivity contrasts between the target and host rocks. This means that for a specific target geometry and conductivity contrast, we need to search such a frequency channel that offers the maximal value for depth of exploration; 3. Among the factors that influence the depth of exploration, the noise level of the HEM system is the key. The other factors include the geometry of the target and the conductivity contrast between the target and the host rocks, and the relative location between the HEM system and the target

  9. Abundâncias em estrelas de Bário

    NASA Astrophysics Data System (ADS)

    Allen, D. M.

    2003-08-01

    Estrelas de Bário apresentam linhas intensas de elementos produzidos pelo processos (ex: Ba, Y, Sr, Zr) e bandas intensas de CN, C2 e CH. A hipótese mais aceita sobre a origem deste grupo peculiar é a de que essas estrelas façam parte de sistemas binários, tendo recebido material enriquecido em elementos pesados da companheira mais evoluída. Apresentamos neste trabalho uma análise detalhada de uma amostra de estrelas desta classe, incluindo determinação de parâmetros atmosféricos e cálculo de abundâncias. As temperaturas efetivas foram determinadas a partir de dados fotométricos obtidos com o Fotrap instalado no telescópio Zeiss do LNA (Laboratório Nacional de Astrofísica) (B-V, V-I, R-I, V-R), e coletados na literatura nos catálogos Hipparcos (B-V), 2MASS (Two Micron All Sky Survey) (V-K) e The General Catalogue Photometric Data (sistema Geneva). Obtivemos uma faixa de temperaturas de 4400 £ Tef £ 6500. As metalicidades foram determinadas a partir de linhas de Fe I e Fe II, estando os resultados no intervalo -1 £ [Fe/H] £ +0.1. O log g foi determinado pelo equilíbrio de ionização e pela relação com a magnitude bolométrica, a temperatura e a massa, sendo os resultados na faixa 1.5 £ log g £ 4.5. As distâncias utilizadas foram determinadas com o auxílio das paralaxes Hipparcos, e as massas determinadas por modelos de isócronas. Os espectros utilizados foram obtidos com o espectrógrafo FEROS no Telescópio de 1,5m do ESO (European Southern Observatory). As abundâncias foram calculadas por meio de síntese espectral de linhas individuais incluindo elementos alfa, pico do Fe, s e r. Encontramos um excesso de elementos pesados em relação ao Fe, como esperado para estrelas de Bário.

  10. Monitoring Survivability and Infectivity of Porcine Epidemic Diarrhea Virus (PEDv) in the Infected On-Farm Earthen Manure Storages (EMS)

    PubMed Central

    Tun, Hein M.; Cai, Zhangbin; Khafipour, Ehsan

    2016-01-01

    In recent years, porcine epidemic diarrhea virus (PEDv) has caused major epidemics, which has been a burden to North America’s swine industry. Low infectious dose and high viability in the environment are major challenges in eradication of this virus. To further understand the viability of PEDv in the infected manure, we longitudinally monitored survivability and infectivity of PEDv in two open earthen manure storages (EMS; previously referred to as lagoon) from two different infected swine farms identified in the province of Manitoba, Canada. Our study revealed that PEDv could survive up to 9 months in the infected EMS after the initial outbreak in the farm. The viral load varied among different layers of the EMS with an average of 1.1 × 105 copies/ml of EMS, independent of EMS temperature and pH. In both studied EMS, the evidence of viral replication was observed through increased viral load in the later weeks of the samplings while there was no new influx of infected manure into the EMS, which was suggestive of presence of potential alternative hosts for PEDv within the EMS. Decreasing infectivity of virus over time irrespective of increased viral load suggested the possibility of PEDv evolution within the EMS and perhaps in the new host that negatively impacted virus infectivity. Viral load in the top layer of the EMS was low and mostly non-infective suggesting that environmental factors, such as UV and sunlight, could diminish the replicability and infectivity of the virus. Thus, frequent agitation of the EMS that could expose virus to UV and sunlight might be a potential strategy for reduction of PEDv load and infectivity in the infected EMS. PMID:27014197

  11. Cryo-EM Structure Determination Using Segmented Helical Image Reconstruction.

    PubMed

    Fromm, S A; Sachse, C

    2016-01-01

    Treating helices as single-particle-like segments followed by helical image reconstruction has become the method of choice for high-resolution structure determination of well-ordered helical viruses as well as flexible filaments. In this review, we will illustrate how the combination of latest hardware developments with optimized image processing routines have led to a series of near-atomic resolution structures of helical assemblies. Originally, the treatment of helices as a sequence of segments followed by Fourier-Bessel reconstruction revealed the potential to determine near-atomic resolution structures from helical specimens. In the meantime, real-space image processing of helices in a stack of single particles was developed and enabled the structure determination of specimens that resisted classical Fourier helical reconstruction and also facilitated high-resolution structure determination. Despite the progress in real-space analysis, the combination of Fourier and real-space processing is still commonly used to better estimate the symmetry parameters as the imposition of the correct helical symmetry is essential for high-resolution structure determination. Recent hardware advancement by the introduction of direct electron detectors has significantly enhanced the image quality and together with improved image processing procedures has made segmented helical reconstruction a very productive cryo-EM structure determination method. PMID:27572732

  12. Specimen Preparation for High-Resolution Cryo-EM.

    PubMed

    Passmore, L A; Russo, C J

    2016-01-01

    Imaging a material with electrons at near-atomic resolution requires a thin specimen that is stable in the vacuum of the transmission electron microscope. For biological samples, this comprises a thin layer of frozen aqueous solution containing the biomolecular complex of interest. The process of preparing a high-quality specimen is often the limiting step in the determination of structures by single-particle electron cryomicroscopy (cryo-EM). Here, we describe a systematic approach for going from a purified biomolecular complex in aqueous solution to high-resolution electron micrographs that are suitable for 3D structure determination. This includes a series of protocols for the preparation of vitrified specimens on various supports, including all-gold and graphene. We also describe techniques for troubleshooting when a preparation fails to yield suitable specimens, and common mistakes to avoid during each part of the process. Finally, we include recommendations for obtaining the highest quality micrographs from prepared specimens with current microscope, detector, and support technology. PMID:27572723

  13. EM modeling for GPIR using 3D FDTD modeling codes

    SciTech Connect

    Nelson, S.D.

    1994-10-01

    An analysis of the one-, two-, and three-dimensional electrical characteristics of structural cement and concrete is presented. This work connects experimental efforts in characterizing cement and concrete in the frequency and time domains with the Finite Difference Time Domain (FDTD) modeling efforts of these substances. These efforts include Electromagnetic (EM) modeling of simple lossless homogeneous materials with aggregate and targets and the modeling dispersive and lossy materials with aggregate and complex target geometries for Ground Penetrating Imaging Radar (GPIR). Two- and three-dimensional FDTD codes (developed at LLNL) where used for the modeling efforts. Purpose of the experimental and modeling efforts is to gain knowledge about the electrical properties of concrete typically used in the construction industry for bridges and other load bearing structures. The goal is to optimize the performance of a high-sample-rate impulse radar and data acquisition system and to design an antenna system to match the characteristics of this material. Results show agreement to within 2 dB of the amplitudes of the experimental and modeled data while the frequency peaks correlate to within 10% the differences being due to the unknown exact nature of the aggregate placement.

  14. The tidal asymmetries and residual flows in Ems Estuary

    NASA Astrophysics Data System (ADS)

    Pein, Johannes Ulrich; Stanev, Emil Vassilev; Zhang, Yinglong Joseph

    2014-12-01

    A 3D unstructured-grid numerical model of the Ems Estuary is presented. The simulated hydrodynamics are compared against tidal gauge data and observations from research cruises. A comparison with an idealized test reveals the capability of the model to reproduce the secondary circulation patterns known from theoretical results. The simulations prove to be accurate and realistic, confirming and extending findings from earlier observations and modeling studies. The basic characteristics of dominant physical processes in the estuary such as tidal amplification, tidal damping, overtide generation, baroclinicity and internal mixing asymmetry are quantified. The model demonstrates an overall dominance of the flood currents in most of the studied area. However, the hypsometric control in the vicinity of Dollart Bay reverses this asymmetry, with the ebb currents stronger than the flood ones. Small-scale bathymetric characteristics and baroclinicity result in a very complex interplay between dominant physical mechanisms in different parts of the tidal channels and over the tidal flats. Residual flow reveals a clear overturning circulation in some parts of the estuary which is related to a mixing asymmetry between flood and ebb currents. We demonstrate that while areas close to the tidal river exhibit overall similarity with density controlled estuarine conditions, in large areas of the outer estuary barotropic forcing and complex bathymetry together with the density distribution affect substantially the horizontal circulation.

  15. PREFACE: EmQM13: Emergent Quantum Mechanics 2013

    NASA Astrophysics Data System (ADS)

    2014-04-01

    These proceedings comprise the invited lectures of the second international symposium on Emergent Quantum Mechanics (EmQM13), which was held at the premises of the Austrian Academy of Sciences in Vienna, Austria, 3-6 October 2013. The symposium was held at the ''Theatersaal'' of the Academy of Sciences, and was devoted to the open exploration of emergent quantum mechanics, a possible ''deeper level theory'' that interconnects three fields of knowledge: emergence, the quantum, and information. Could there appear a revised image of physical reality from recognizing new links between emergence, the quantum, and information? Could a novel synthesis pave the way towards a 21st century, ''superclassical'' physics? The symposium provided a forum for discussing (i) important obstacles which need to be overcome as well as (ii) promising developments and research opportunities on the way towards emergent quantum mechanics. Contributions were invited that presented current advances in both standard as well as unconventional approaches to quantum mechanics. The EmQM13 symposium was co-organized by Gerhard Grössing (Austrian Institute for Nonlinear Studies (AINS), Vienna), and by Jan Walleczek (Fetzer Franklin Fund, USA, and Phenoscience Laboratories, Berlin). After a very successful first conference on the same topic in 2011, the new partnership between AINS and the Fetzer Franklin Fund in producing the EmQM13 symposium was able to further expand interest in the promise of emergent quantum mechanics. The symposium consisted of two parts, an opening evening addressing the general public, and the scientific program of the conference proper. The opening evening took place at the Great Ceremonial Hall (Grosser Festsaal) of the Austrian Academy of Sciences, and it presented talks and a panel discussion on ''The Future of Quantum Mechanics'' with three distinguished speakers: Stephen Adler (Princeton), Gerard 't Hooft (Utrecht) and Masanao Ozawa (Nagoya). The articles contained in

  16. Orthogonalizing EM: A design-based least squares algorithm

    PubMed Central

    Xiong, Shifeng; Dai, Bin; Huling, Jared; Qian, Peter Z. G.

    2016-01-01

    We introduce an efficient iterative algorithm, intended for various least squares problems, based on a design of experiments perspective. The algorithm, called orthogonalizing EM (OEM), works for ordinary least squares and can be easily extended to penalized least squares. The main idea of the procedure is to orthogonalize a design matrix by adding new rows and then solve the original problem by embedding the augmented design in a missing data framework. We establish several attractive theoretical properties concerning OEM. For the ordinary least squares with a singular regression matrix, an OEM sequence converges to the Moore-Penrose generalized inverse-based least squares estimator. For ordinary and penalized least squares with various penalties, it converges to a point having grouping coherence for fully aliased regression matrices. Convergence and the convergence rate of the algorithm are examined. Finally, we demonstrate that OEM is highly efficient for large-scale least squares and penalized least squares problems, and is considerably faster than competing methods when n is much larger than p. Supplementary materials for this article are available online. PMID:27499558

  17. If EM waves don't interfere, what causes interferograms?

    NASA Astrophysics Data System (ADS)

    Wellard, Stanley J.

    2012-10-01

    Photonics engineers involved in designing and operating Fourier transform spectrometers (FTS) often rely on Maxwell's wave equations and time-frequency (distance-wavenumber) Fourier theory as models to understand and predict the conversion of optical energy to electrical signals in their instruments. Dr. Chandrasekhar Roychoudhuri and his colleagues, at last year's conference, presented three significant concepts that might completely change the way we comprehend the interaction of light and matter and the way interference information is generated. The first concept is his non-interaction of waves (NIW) formulation, which puts in place an optical wave description that more accurately describe the properties of the finite time and spatial signals of an optical system. The second is a new description for the cosmic EM environment that recognizes that space is really filled with the ether of classical electromagnetics. The third concept is a new metaphysics or metaphotonics that compares the photon as a particle in a void against the photon as a wave in a medium to see which best explain the twelve different aspects of light. Dr. Henry Lindner presents a compelling case that photons are waves in a medium and particles (electrons, protons, atoms) are wave-structures embedded in the new ether. Discussion of the three new principles is intended to increase the curiosity of photonics engineers to investigate these changes in the nature of light and matter.

  18. Overexpression of OsEm1 encoding a group I LEA protein confers enhanced drought tolerance in rice.

    PubMed

    Yu, Jing; Lai, Yongmin; Wu, Xi; Wu, Gang; Guo, Changkui

    2016-09-16

    Drought is the greatest threat for crops, including rice. In an effort to identify rice genes responsible for drought tolerance, a drought-responsive gene OsEm1 encoding a group I LEA protein, was chosen for this study. OsEm1 was shown at vegetative stages to be responsive to various abiotic stresses, including drought, salt, cold and the hormone ABA. In this study, we generated OsEm1-overexpressing rice plants to explore the function of OsEm1 under drought conditions. Overexpression of OsEm1 increases ABA sensitivity and enhances osmotic tolerance in rice. Compared with wild type, the OsEm1-overexpressing rice plants showed enhanced plant survival ratio at the vegetative stage; moreover, over expression of OsEm1 in rice increased the expression of other LEA genes, including RAB16A, RAB16C, RAB21, and LEA3, likely protecting organ integrity against harsh environments. Interestingly, the elevated level of OsEm1 had no different phenotype compared with wild type under normal condition. Our findings suggest that OsEm1 is a positive regulator of drought tolerance and is potentially promising for engineering drought tolerance in rice. PMID:27524243

  19. An EM algorithm for estimating SPECT emission and transmission parameters from emissions data only.

    PubMed

    Krol, A; Bowsher, J E; Manglos, S H; Feiglin, D H; Tornai, M P; Thomas, F D

    2001-03-01

    A maximum-likelihood (ML) expectation-maximization (EM) algorithm (called EM-IntraSPECT) is presented for simultaneously estimating single photon emission computed tomography (SPECT) emission and attenuation parameters from emission data alone. The algorithm uses the activity within the patient as transmission tomography sources, with which attenuation coefficients can be estimated. For this initial study, EM-IntraSPECT was tested on computer-simulated attenuation and emission maps representing a simplified human thorax as well as on SPECT data obtained from a physical phantom. Two evaluations were performed. First, to corroborate the idea of reconstructing attenuation parameters from emission data, attenuation parameters (mu) were estimated with the emission intensities (lambda) fixed at their true values. Accurate reconstructions of attenuation parameters were obtained. Second, emission parameters lambda and attenuation parameters mu were simultaneously estimated from the emission data alone. In this case there was crosstalk between estimates of lambda and mu and final estimates of lambda and mu depended on initial values. Estimates degraded significantly as the support extended out farther from the body, and an explanation for this is proposed. In the EM-IntraSPECT reconstructed attenuation images, the lungs, spine, and soft tissue were readily distinguished and had approximately correct shapes and sizes. As compared with standard EM reconstruction assuming a fix uniform attenuation map, EM-IntraSPECT provided more uniform estimates of cardiac activity in the physical phantom study and in the simulation study with tight support, but less uniform estimates with a broad support. The new EM algorithm derived here has additional applications, including reconstructing emission and transmission projection data under a unified statistical model. PMID:11341711

  20. National Prehospital Evidence-Based Guidelines Strategy: A Summary for EMS Stakeholders.

    PubMed

    Martin-Gill, Christian; Gaither, Joshua B; Bigham, Blair L; Myers, J Brent; Kupas, Douglas F; Spaite, Daniel W

    2016-01-01

    Multiple national organizations have recommended and supported a national investment to increase the scientific evidence available to guide patient care delivered by Emergency Medical Services (EMS) and incorporate that evidence directly into EMS systems. Ongoing efforts seek to develop, implement, and evaluate prehospital evidence-based guidelines (EBGs) using the National Model Process created by a multidisciplinary panel of experts convened by the Federal Interagency Committee on EMS (FICEMS) and the National EMS Advisory Council (NEMSAC). Yet, these and other EBG efforts have occurred in relative isolation, with limited direct collaboration between national projects, and have experienced challenges in implementation of individual guidelines. There is a need to develop sustainable relationships among stakeholders that facilitate a common vision that facilitates EBG efforts. Herein, we summarize a National Strategy on EBGs developed by the National Association of EMS Physicians (NAEMSP) with involvement of 57 stakeholder organizations, and with the financial support of the National Highway Traffic Safety Administration (NHTSA) and the EMS for Children program. The Strategy proposes seven action items that support collaborative efforts in advancing prehospital EBGs. The first proposed action is creation of a Prehospital Guidelines Consortium (PGC) representing national medical and EMS organizations that have an interest in prehospital EBGs and their benefits to patient outcomes. Other action items include promoting research that supports creation and evaluates the impact of EBGs, promoting the development of new EBGs through improved stakeholder collaboration, and improving education on evidence-based medicine for all prehospital providers. The Strategy intends to facilitate implementation of EBGs by improving guideline dissemination and incorporation into protocols, and seeks to establish standardized evaluation methods for prehospital EBGs. Finally, the Strategy

  1. Methicillin-resistant Staphylococcus aureus in Ohio EMS Providers: A Statewide Cross-sectional Study.

    PubMed

    Orellana, Robert C; Hoet, Armando E; Bell, Christopher; Kelley, Christina; Lu, Bo; Anderson, Sarah E; Stevenson, Kurt B

    2016-01-01

    The objective was to determine the nasal carriage prevalence of methicillin-resistant Staphylococcus aureus (MRSA) among emergency medical service (EMS) personnel and the associated risk factors. A cross-sectional study was conducted among Ohio EMS personnel randomly sampled from 84 urban and rural agencies. Surveys assessing demographics, occupational history, health, cohabitation status, and hygiene practice were collected with nasal swabs from those who enrolled. Survey weight adjusted analysis was performed (1) to estimate MRSA nasal carriage prevalence of Ohio EMS providers, and (2) to identify variables associated with MRSA. MRSA was detected in 4.6% (13/280) EMS personnel sampled. After employing a survey-weighted analysis the following risk factors associated with MRSA carriage were identified: those who did not practice frequent hand hygiene after glove use (OR, 10.51; 95% CI, 2.54-43.45; P = 0.0012), living with someone with a recent staphylococcal infection (OR, 9.02; 95% CI, 1.03-78.98; P = 0.0470), and individuals with low frequency of hand washing (< 8 times per shift) (OR, 4.20; 95% CI 1.02-17.27; P = 0.0468). An additional risk factor identified through the logistic regression analysis on the study population was EMS workers with an open wound or skin infection (OR, 6.75; 95% CI, 1.25-36.36; P = 0.0262). However, this was not significant in the survey-weighted analysis. The high prevalence of MRSA in Ohio EMS personnel is both an occupational hazard and patient safety concern. Implementing methods to reinforce CDC guidelines for proper hygiene could decrease MRSA found in the EMS setting. Previous literature suggests that a reduction in MRSA colonization can lead to decreases in transmission and improved health for both patients and personnel. PMID:26516797

  2. OV-Wav: um novo pacote para análise multiescalar em astronomia

    NASA Astrophysics Data System (ADS)

    Pereira, D. N. E.; Rabaça, C. R.

    2003-08-01

    Wavelets e outras formas de análise multiescalar têm sido amplamente empregadas em diversas áreas do conhecimento, sendo reconhecidamente superiores a técnicas mais tradicionais, como as análises de Fourier e de Gabor, em certas aplicações. Embora a teoria dos wavelets tenha começado a ser elaborada há quase trinta anos, seu impacto no estudo de imagens astronômicas tem sido pequeno até bem recentemente. Apresentamos um conjunto de programas desenvolvidos ao longo dos últimos três anos no Observatório do Valongo/UFRJ que possibilitam aplicar essa poderosa ferramenta a problemas comuns em astronomia, como a remoção de ruído, a detecção hierárquica de fontes e a modelagem de objetos com perfis de brilho arbitrários em condições não ideais. Este pacote, desenvolvido para execução em plataforma IDL, teve sua primeira versão concluída recentemente e está sendo disponibilizado à comunidade científica de forma aberta. Mostramos também resultados de testes controlados ao quais submetemos os programas, com a sua aplicação a imagens artificiais, com resultados satisfatórios. Algumas aplicações astrofísicas foram estudadas com o uso do pacote, em caráter experimental, incluindo a análise da componente de luz difusa em grupos compactos de galáxias de Hickson e o estudo de subestruturas de nebulosas planetárias no espaço multiescalar.

  3. Immune protection of microneme 7 (EmMIC7) against Eimeria maxima challenge in chickens.

    PubMed

    Huang, Jingwei; Zhang, Zhenchao; Li, Menghui; Song, Xiaokai; Yan, Ruofeng; Xu, Lixin; Li, Xiangrui

    2015-10-01

    In the present study, the immune protective effects of recombinant microneme protein 7 of Eimeria maxima (rEmMIC7) and a DNA vaccine encoding this antigen (pVAX1-EmMIC7) on experimental challenge were evaluated. Two-week-old chickens were randomly divided into five groups. Experimental groups of chickens were immunized with 100 μg DNA vaccine pVAX1-MIC7 or 200 μg rEmMIC7, while control groups of chickens were injected with pVAX1 plasmid or sterile phosphate buffered saline (PBS). The results showed that the anti-EmMIC7 antibody titres in chickens of both rEmMIC7 and pVAX1-MIC7 groups were significantly higher as compared to PBS and pVAX1 control (P < .05). The splenocytes from both vaccinated groups of chickens displayed significantly greater proliferation response compared with the controls (P < .05). Serum from chickens immunized with pVAX1-MIC7 and rEmMIC7 displayed significantly high levels of interleukin-2, interferon-γ, IL-10, IL-17, tumour growth factor-β and IL-4 (P < .05) compared to those of negative controls. The challenge experiment results showed that both the recombinant antigen and the DNA vaccine could obviously alleviate jejunum lesions, body weight loss and enhance oocyst decrease ratio. The anti-coccidial index (ACI) of the pVAX1-MIC7 group was 167.84, higher than that of the recombinant MIC7 protein group, 167.10. Our data suggested that immunization with EmMIC7 was effective in imparting partial protection against E. maxima challenge in chickens and it could be an effective antigen candidate for the development of new vaccines against E. maxima. PMID:26181095

  4. Prevention and Immunotherapy of Secondary Murine Alveolar Echinococcosis Employing Recombinant EmP29 Antigen

    PubMed Central

    Boubaker, Ghalia; Hemphill, Andrew; Huber, Cristina Olivia; Spiliotis, Markus; Babba, Hamouda; Gottstein, Bruno

    2015-01-01

    Alveolar echinococcosis (AE) is caused by infection with the larval stage of the tapeworm Echinococcus multilocularis. An increasing understanding of immunological events that account for the metacestode survival in human and murine AE infection prompted us to undertake explorative experiments tackling the potential of novel preventive and/or immunotherapeutic measures. In this study, the immunoprotective and immunotherapeutic ability of recombinant EmP29 antigen (rEmP29) was assessed in mice that were intraperitoneally infected with E. multilocularis metacestodes. For vaccination, three intraperitoneal injections with 20μg rEmP29 emulsified in saponin adjuvants were applied over 6 weeks. 2 weeks after the last boost, mice were infected, and at 90 days post-infection, rEmP29-vaccinated mice exhibited a median parasite weight that was reduced by 75% and 59% when compared to NaCl- or saponin–treated control mice, respectively. For immunotherapeutical application, the rEmP29 (20μg) vaccine was administered to experimentally infected mice, starting at 1 month post-infection, three times with 2 weeks intervals. Mice undergoing rEmP29 immunotherapy exhibited a median parasite load that was reduced by 53% and 49% when compared to NaCl- and saponin–treated control mice, respectively. Upon analysis of spleen cells, both, vaccination and treatment with rEmP29, resulted in low ratios of Th2/Th1 (IL-4/IFN-γ) cytokine mRNA and low levels of mRNA coding for IL-10 and IL-2. These results suggest that reduction of the immunosuppressive environment takes place in vaccinated as well as immunotreated mice, and a shift towards a Th1 type of immune response may be responsible for the observed increased restriction of parasite growth. The present study provides the first evidence that active immunotherapy may present a sustainable route for the control of AE. PMID:26053794

  5. EM-54 Technology Development In Situ Remediation Integrated Program. Annual report

    SciTech Connect

    Not Available

    1993-08-01

    The Department of Energy (DOE) established the Office of Technology Development (EM-50) as an element of Environmental Restoration and Waste Management (EM) in November 1989. EM manages remediation of all DOE sites as well as wastes from current operations. The goal of the EM program is to minimize risks to human health, safety and the environment, and to bring all DOE sites into compliance with Federal, state, and local regulations by 2019. EM-50 is charged with developing new technologies that are safer, more effective and less expensive than current methods. The In Situ Remediation Integrated Program (the subject of this report) is part of EM-541, the Environmental Restoration Research and Development Division of EM-54. The In Situ Remediation Integrated Program (ISR IP) was instituted out of recognition that in situ remediation could fulfill three important criteria: Significant cost reduction of cleanup by eliminating or minimizing excavation, transportation, and disposal of wastes; reduced health impacts on workers and the public by minimizing exposure to wastes during excavation and processing; and remediation of inaccessible sites, including: deep subsurfaces; in, under, and around buildings. Buried waste, contaminated soils and groundwater, and containerized wastes are all candidates for in situ remediation. Contaminants include radioactive wastes, volatile and non-volatile organics, heavy metals, nitrates, and explosive materials. The ISR IP tends to facilitate development of in situ remediation technologies for hazardous, radioactive, and mixed wastes in soils, groundwater, and storage tanks. Near-term focus is on containment of the wastes, with treatment receiving greater effort in future years.

  6. Cystatin E/M Suppresses Tumor Cell Growth through Cytoplasmic Retention of NF-κB.

    PubMed

    Soh, Hendrick; Venkatesan, Natarajan; Veena, Mysore S; Ravichandran, Sandhiya; Zinabadi, Alborz; Basak, Saroj K; Parvatiyar, Kislay; Srivastava, Meera; Liang, Li-Jung; Gjertson, David W; Torres, Jorge Z; Moatamed, Neda A; Srivatsan, Eri S

    2016-06-15

    We and others have shown that the cystatin E/M gene is inactivated in primary human tumors, pointing to its role as a tumor suppressor gene. However, the molecular mechanism of tumor suppression is not yet understood. Using plasmid-directed cystatin E/M gene overexpression, a lentivirus-mediated tetracycline-inducible vector system, and human papillomavirus 16 (HPV 16) E6 and E7 gene-immortalized normal human epidermal keratinocytes, we demonstrated intracellular and non-cell-autonomous apoptotic growth inhibition of tumor cell lines and that growth inhibition is associated with cytoplasmic retention of NF-κB. We further demonstrated decreased phosphorylation of IκB kinase (IKKβ) and IκBα in the presence of tumor necrosis factor alpha (TNF-α), confirming the role of cystatin E/M in the regulation of the NF-κB signaling pathway. Growth suppression of nude mouse xenograft tumors carrying a tetracycline-inducible vector system was observed with the addition of doxycycline in drinking water, confirming that the cystatin E/M gene is a tumor suppressor gene. Finally, immunohistochemical analyses of cervical carcinoma in situ and primary tumors have shown a statistically significant inverse relationship between the expression of cystatin E/M and cathepsin L and a direct relationship between the loss of cystatin E/M expression and nuclear expression of NF-κB. We therefore propose that the cystatin E/M suppressor gene plays an important role in the regulation of NF-κB. PMID:27090639

  7. Compositions of HIMU, EM1, and EM2 from global trends between radiogenic isotopes and major elements in ocean island basalts

    NASA Astrophysics Data System (ADS)

    Jackson, Matthew G.; Dasgupta, Rajdeep

    2008-11-01

    Sr and Pb isotopes exhibit global trends with the concentrations of major elements (SiO 2, TiO 2, FeO, Al 2O 3 and K 2O) and major elements ratios (CaO/Al 2O 3 and K 2O/TiO 2) in the shield-stage lavas from 18 oceanic hotspots (including Hawaii, Iceland, Galapagos, Cook-Australs, St. Helena, Cape Verde, Cameroon, Canary, Madeira, Comoros, Azores, Samoa, Society, Marquesas, Mascarene, Kerguelen, Pitcairn, and Selvagen). Based on the relationships between major elements and isotopes in ocean island basalts (OIBs), we find that the lavas derived from the mantle end members, HIMU (or high 'μ' = 238U/ 204Pb), EM1 (enriched mantle 1), EM2 (enriched mantle 2), and DMM (depleted MORB [mid-ocean ridge basalt] mantle) exhibit distinct major element characteristics: When compared to oceanic hotspots globally, the hotspots with a HIMU (radiogenic Pb-isotopes and low 87Sr/ 86Sr) component, such as St. Helena and Cook-Australs, exhibit high CaO/Al 2O 3, FeO T, and TiO 2 and low SiO 2 and Al 2O 3. EM1 (enriched mantle 1; intermediate 87Sr/ 86Sr and low 206Pb/ 204Pb; sampled by hotspots like Pitcairn and Kerguelen) and EM2 (enriched mantle 2; high 87Sr/ 86Sr and intermediate 206Pb/ 204Pb; sampled by hotspots like Samoa and Societies) exhibit higher K 2O concentrations and K 2O/TiO 2 weight ratios than HIMU lavas. EM1 lavas exhibit the lowest CaO/Al 2O 3 in the OIB dataset, and this sets EM1 apart from EM2. A plot of CaO/Al 2O 3 vs K 2O/TiO 2 perfectly resolves the four mantle end member lavas. Melting processes (pressure, temperature and degree of melting) fail to provide an explanation for the full spectrum of major element concentrations in OIBs. Such processes also fail to explain the correlations between major elements and radiogenic isotopes. Instead, a long, time integrated history of various parent-daughter elements appears to be coupled to major element and/or volatile heterogeneity in the mantle source. End member lava compositions are compared with experimental partial

  8. Pre-flight risk assessment in Emergency Medical Service (EMS) helicopters

    NASA Technical Reports Server (NTRS)

    Shively, R. J.

    1992-01-01

    The Emergency Medical Service (EMS) industry has been the subject of several television and newspaper articles (Harvey and Jensen, 1987) which emphasized the negative aspects, (e.g., fatalities and high accident rates), rather than the life saving services performed. Until recently, the accident rate of the EMS industry has been five times as high as that of other civil helicopters. This high accident rate has been coupled with the dramatic rise in the number of programs. The industry has built from a single service at its inception in 1972, to over 180 in 1987 (Spray, 1987), to the point that 93 percent of the contiguous U.S. is now covered by some type of EMS service. These factors prompted the National Transportation Safety Board (NTSB) to study the accidents that occurred between May 11, 1978 and December 3, 1986 (NTSB, 1988). The NTSB report concluded that 'Sound pilot judgment is central to safe flight operations.' They further stated that '... factors unique to EMS helicopter operations--such as the influence of the mission itself, program competition, and EMS program management perspectives--can drastically influence pilot judgment during the EMS mission.' One of the most difficult decisions that a pilot must make is whether to accept or decline a mission. A pre-flight risk assessment system (SAFE) was developed at NASA-Ames Research Center for civil EMS operations to aid pilots in making this decision objectively. The ability of the SAFE system to predict mission risk profiles was tested at an EMS facility. The results of this field study demonstrated that the usefulness of SAFE was highly dependent on the type of mission flown. SAFE is now being modified so that it can 'learn' with each mission flown. For example, after flying a mission to a particular site, an EMS pilot would input information about this mission into the system, such as new buildings, wires, or approach procedures. Then, the next time a pilot flew a similar mission or one to the same

  9. Rock 'Em, Sock 'Em!

    ERIC Educational Resources Information Center

    Waters, John K.

    2011-01-01

    K-12-level competitive robotics is growing in popularity around the country and worldwide. According to one of the leading organizers of these events, FIRST--For Inspiration and Recognition of Science and Technology--250,000 students from 56 countries take part in its competitions. FIRST Tech Challenge (FTC) is a yearly event the organization puts…

  10. Incubator embedded cell culture imaging system (EmSight) based on Fourier ptychographic microscopy.

    PubMed

    Kim, Jinho; Henley, Beverley M; Kim, Charlene H; Lester, Henry A; Yang, Changhuei

    2016-08-01

    Multi-day tracking of cells in culture systems can provide valuable information in bioscience experiments. We report the development of a cell culture imaging system, named EmSight, which incorporates multiple compact Fourier ptychographic microscopes with a standard multiwell imaging plate. The system is housed in an incubator and presently incorporates six microscopes. By using the same low magnification objective lenses as the objective and the tube lens, the EmSight is configured as a 1:1 imaging system that, providing large field-of-view (FOV) imaging onto a low-cost CMOS imaging sensor. The EmSight improves the image resolution by capturing a series of images of the sample at varying illumination angles; the instrument reconstructs a higher-resolution image by using the iterative Fourier ptychographic algorithm. In addition to providing high-resolution brightfield and phase imaging, the EmSight is also capable of fluorescence imaging at the native resolution of the objectives. We characterized the system using a phase Siemens star target, and show four-fold improved coherent resolution (synthetic NA of 0.42) and a depth of field of 0.2 mm. To conduct live, long-term dopaminergic neuron imaging, we cultured ventral midbrain from mice driving eGFP from the tyrosine hydroxylase promoter. The EmSight system tracks movements of dopaminergic neurons over a 21 day period. PMID:27570701

  11. Description and comparison of algorithms for correcting anisotropic magnification in cryo-EM images.

    PubMed

    Zhao, Jianhua; Brubaker, Marcus A; Benlekbir, Samir; Rubinstein, John L

    2015-11-01

    Single particle electron cryomicroscopy (cryo-EM) allows for structures of proteins and protein complexes to be determined from images of non-crystalline specimens. Cryo-EM data analysis requires electron microscope images of randomly oriented ice-embedded protein particles to be rotated and translated to allow for coherent averaging when calculating three-dimensional (3D) structures. Rotation of 2D images is usually done with the assumption that the magnification of the electron microscope is the same in all directions. However, due to electron optical aberrations, this condition is not met with some electron microscopes when used with the settings necessary for cryo-EM with a direct detector device (DDD) camera. Correction of images by linear interpolation in real space has allowed high-resolution structures to be calculated from cryo-EM images for symmetric particles. Here we describe and compare a simple real space method, a simple Fourier space method, and a somewhat more sophisticated Fourier space method to correct images for a measured anisotropy in magnification. Further, anisotropic magnification causes contrast transfer function (CTF) parameters estimated from image power spectra to have an apparent systematic astigmatism. To address this problem we develop an approach to adjust CTF parameters measured from distorted images so that they can be used with corrected images. The effect of anisotropic magnification on CTF parameters provides a simple way of detecting magnification anisotropy in cryo-EM datasets. PMID:26087140

  12. dbEM: A database of epigenetic modifiers curated from cancerous and normal genomes

    PubMed Central

    Singh Nanda, Jagpreet; Kumar, Rahul; Raghava, Gajendra P. S.

    2016-01-01

    We have developed a database called dbEM (database of Epigenetic Modifiers) to maintain the genomic information of about 167 epigenetic modifiers/proteins, which are considered as potential cancer targets. In dbEM, modifiers are classified on functional basis and comprise of 48 histone methyl transferases, 33 chromatin remodelers and 31 histone demethylases. dbEM maintains the genomic information like mutations, copy number variation and gene expression in thousands of tumor samples, cancer cell lines and healthy samples. This information is obtained from public resources viz. COSMIC, CCLE and 1000-genome project. Gene essentiality data retrieved from COLT database further highlights the importance of various epigenetic proteins for cancer survival. We have also reported the sequence profiles, tertiary structures and post-translational modifications of these epigenetic proteins in cancer. It also contains information of 54 drug molecules against different epigenetic proteins. A wide range of tools have been integrated in dbEM e.g. Search, BLAST, Alignment and Profile based prediction. In our analysis, we found that epigenetic proteins DNMT3A, HDAC2, KDM6A, and TET2 are highly mutated in variety of cancers. We are confident that dbEM will be very useful in cancer research particularly in the field of epigenetic proteins based cancer therapeutics. This database is available for public at URL: http://crdd.osdd.net/raghava/dbem. PMID:26777304

  13. Cryo-EM studies of the structure and dynamics of vacuolar-type ATPases.

    PubMed

    Mazhab-Jafari, Mohammad T; Rubinstein, John L

    2016-07-01

    Electron cryomicroscopy (cryo-EM) has significantly advanced our understanding of molecular structure in biology. Recent innovations in both hardware and software have made cryo-EM a viable alternative for targets that are not amenable to x-ray crystallography or nuclear magnetic resonance (NMR) spectroscopy. Cryo-EM has even become the method of choice in some situations where x-ray crystallography and NMR spectroscopy are possible but where cryo-EM can determine structures at higher resolution or with less time or effort. Rotary adenosine triphosphatases (ATPases) are crucial to the maintenance of cellular homeostasis. These enzymes couple the synthesis or hydrolysis of adenosine triphosphate to the use or production of a transmembrane electrochemical ion gradient, respectively. However, the membrane-embedded nature and conformational heterogeneity of intact rotary ATPases have prevented their high-resolution structural analysis to date. Recent application of cryo-EM methods to the different types of rotary ATPase has led to sudden advances in understanding the structure and function of these enzymes, revealing significant conformational heterogeneity and characteristic transmembrane α helices that are highly tilted with respect to the membrane. In this Review, we will discuss what has been learned recently about rotary ATPase structure and function, with a particular focus on the vacuolar-type ATPases. PMID:27532044

  14. Incubator embedded cell culture imaging system (EmSight) based on Fourier ptychographic microscopy

    PubMed Central

    Kim, Jinho; Henley, Beverley M.; Kim, Charlene H.; Lester, Henry A.; Yang, Changhuei

    2016-01-01

    Multi-day tracking of cells in culture systems can provide valuable information in bioscience experiments. We report the development of a cell culture imaging system, named EmSight, which incorporates multiple compact Fourier ptychographic microscopes with a standard multiwell imaging plate. The system is housed in an incubator and presently incorporates six microscopes. By using the same low magnification objective lenses as the objective and the tube lens, the EmSight is configured as a 1:1 imaging system that, providing large field-of-view (FOV) imaging onto a low-cost CMOS imaging sensor. The EmSight improves the image resolution by capturing a series of images of the sample at varying illumination angles; the instrument reconstructs a higher-resolution image by using the iterative Fourier ptychographic algorithm. In addition to providing high-resolution brightfield and phase imaging, the EmSight is also capable of fluorescence imaging at the native resolution of the objectives. We characterized the system using a phase Siemens star target, and show four-fold improved coherent resolution (synthetic NA of 0.42) and a depth of field of 0.2 mm. To conduct live, long-term dopaminergic neuron imaging, we cultured ventral midbrain from mice driving eGFP from the tyrosine hydroxylase promoter. The EmSight system tracks movements of dopaminergic neurons over a 21 day period. PMID:27570701

  15. Cryo-EM studies of the structure and dynamics of vacuolar-type ATPases

    PubMed Central

    Mazhab-Jafari, Mohammad T.; Rubinstein, John L.

    2016-01-01

    Electron cryomicroscopy (cryo-EM) has significantly advanced our understanding of molecular structure in biology. Recent innovations in both hardware and software have made cryo-EM a viable alternative for targets that are not amenable to x-ray crystallography or nuclear magnetic resonance (NMR) spectroscopy. Cryo-EM has even become the method of choice in some situations where x-ray crystallography and NMR spectroscopy are possible but where cryo-EM can determine structures at higher resolution or with less time or effort. Rotary adenosine triphosphatases (ATPases) are crucial to the maintenance of cellular homeostasis. These enzymes couple the synthesis or hydrolysis of adenosine triphosphate to the use or production of a transmembrane electrochemical ion gradient, respectively. However, the membrane-embedded nature and conformational heterogeneity of intact rotary ATPases have prevented their high-resolution structural analysis to date. Recent application of cryo-EM methods to the different types of rotary ATPase has led to sudden advances in understanding the structure and function of these enzymes, revealing significant conformational heterogeneity and characteristic transmembrane α helices that are highly tilted with respect to the membrane. In this Review, we will discuss what has been learned recently about rotary ATPase structure and function, with a particular focus on the vacuolar-type ATPases. PMID:27532044

  16. Association of Disomic Chromosome Loss with Ems-Induced Conversion in Yeast

    PubMed Central

    Campbell, Douglas

    1980-01-01

    Experimental tests with the yeast Saccharomyces cerevisiae of a previously proposed model suggesting a causal relationship between disomic chromosome loss (n + 1 → n) and centromere-adjacent mitotic gene conversion were performed. Disomic haploid cells heteroallelic at two loci on the left arm of chromosome III were exposed to ethyl methanesulfonate (EMS) under nonlethal conditions; EMS-induced prototrophic gene convertants were selected and tested for coincident chromosome loss. The principal results are: (1) The frequency of chromosome loss among EMS-induced gene convertants selected to arise near the centromere is markedly enhanced over basal levels and remains constant, independent of EMS exposure. There is little such enhancement among EMS-induced convertants selected to arise far from the centromere. (2) Chromosome loss is almost completely associated with induced conversion of the centromere-proximal allele at the centromere-adjacent heteroallelic locus. This result is identical to (and confirms) results found previously for spontaneous loss-associated conversion. (3) The conversion polarity at the centromere-adjacent locus among unselected (nonloss-associated) induced or spontaneous mitotic convertants is identical to that among meiotic convertants and markedly favors the contromere-distal allele. These findings are wholly consistent with, and strengthen, the hypothesis that structural involvement of centromeric regions in nearby recombinational events may interfere with proper segregational function and lead to mitotic chromosome loss. PMID:7021313

  17. Randomized controlled trial of a scoring aid to improve GCS scoring by EMS providers (Brief Report)

    PubMed Central

    Feldman, Amanda Lynn; Hart, Kimberly Ward; Lindsell, Christopher John; McMullan, Jason T.

    2014-01-01

    Objective Emergency medical services (EMS) personnel frequently use the Glasgow Coma Scale (GCS) to assess injured and critically ill patients. This study assessed the accuracy of EMS providers’ GCS scoring as well as the improvement in GCS assessment with the use of a scoring aid. Methods This randomized, controlled study was conducted in the emergency department (ED) of an urban, academic trauma center. Emergency medical technicians or paramedics who transported a patient to the ED were randomly assessed one of nine written scenarios, either with or without a GCS scoring aid. Scenarios were created by consensus of expert attending emergency medicine, EMS, and neurocritical care physicians with universal consensus agreement on GCS scores. Chi-square and student’s t-tests were used to compare groups. Results Of 180 participants, 178 completed the study. Overall, 73/178 (41%) participants gave a GCS score that matched the expert consensus score. GCS was correct in 22/88 (25%) of cases without the scoring aid. GCS was correct in 51/90 (57%) of cases with the scoring aid. Most (69%) of total GCS scores fell within one point of the expert consensus GCS score. Differences in accuracy were most pronounced in scenarios with a correct GCS of 12 or below. Sub-component accuracy was: eye 62%, verbal 70%, and motor 51%. Conclusion In this study, 60% of EMS participants provided inaccurate GCS estimates. Use of a GCS scoring aid improved accuracy of EMS GCS assessments. PMID:25199613

  18. Scalable and interactive segmentation and visualization of neural processes in EM datasets.

    PubMed

    Jeong, Won-Ki; Beyer, Johanna; Hadwiger, Markus; Vazquez, Amelio; Pfister, Hanspeter; Whitaker, Ross T

    2009-01-01

    Recent advances in scanning technology provide high resolution EM (Electron Microscopy) datasets that allow neuro-scientists to reconstruct complex neural connections in a nervous system. However, due to the enormous size and complexity of the resulting data, segmentation and visualization of neural processes in EM data is usually a difficult and very time-consuming task. In this paper, we present NeuroTrace, a novel EM volume segmentation and visualization system that consists of two parts: a semi-automatic multiphase level set segmentation with 3D tracking for reconstruction of neural processes, and a specialized volume rendering approach for visualization of EM volumes. It employs view-dependent on-demand filtering and evaluation of a local histogram edge metric, as well as on-the-fly interpolation and ray-casting of implicit surfaces for segmented neural structures. Both methods are implemented on the GPU for interactive performance. NeuroTrace is designed to be scalable to large datasets and data-parallel hardware architectures. A comparison of NeuroTrace with a commonly used manual EM segmentation tool shows that our interactive workflow is faster and easier to use for the reconstruction of complex neural processes. PMID:19834227

  19. Elimination of error factors, affecting EM and seismic inversions

    NASA Astrophysics Data System (ADS)

    Magomedov, M.; Zuev, M. A.; Korneev, V. A.; Goloshubin, G.; Zuev, J.; Brovman, Y.

    2013-12-01

    EM or seismic data inversions are affected by many factors, which may conceal the responses from target objects. We address here the contributions from the following effects: 1) Pre-survey spectral sensitivity factor. Preliminary information about a target layer can be used for a pre-survey estimation of the required frequency domain and signal level. A universal approach allows making such estimations in real time, helping the survey crew to optimize an acquisition process. 2) Preliminary velocities' identification and their dispersions for all the seismic waves, arising in a stratified media became a fast working tool, based on the exact analytical solution. 3) Vertical gradients effect. For most layers the log data scatter, requiring an averaging pattern. A linear gradient within each representative layer is a reasonable compromise between required inversion accuracy and forward modeling complexity. 4) An effect from the seismic source's radial component becomes comparable with vertical part for explosive sources. If this effect is not taken into account, a serious modeling error takes place. This problem has an algorithmic solution. 5) Seismic modeling is often based on different representations for a source formulated either for a force or to a potential. The wave amplitudes depend on the formulation, making an inversion result sensitive to it. 6) Asymmetrical seismic waves (modified Rayleigh) in symmetrical geometry around liquid fracture come from S-wave and merge with the modified Krauklis wave at high frequencies. A detail analysis of this feature allows a spectral range optimization for the proper wave's extraction. 7) An ultrasonic experiment was conducted to show different waves appearance for a super-thin water-saturated fracture between two Plexiglas plates, being confirmed by comparison with theoretical computations. 8) A 'sandwich effect' was detected by comparison with averaged layer's effect. This opens an opportunity of the shale gas direct

  20. EM algorithm applied for estimating non-stationary region boundaries using electrical impedance tomography

    NASA Astrophysics Data System (ADS)

    Khambampati, A. K.; Rashid, A.; Kim, B. S.; Liu, Dong; Kim, S.; Kim, K. Y.

    2010-04-01

    EIT has been used for the dynamic estimation of organ boundaries. One specific application in this context is the estimation of lung boundaries during pulmonary circulation. This would help track the size and shape of lungs of the patients suffering from diseases like pulmonary edema and acute respiratory failure (ARF). The dynamic boundary estimation of the lungs can also be utilized to set and control the air volume and pressure delivered to the patients during artificial ventilation. In this paper, the expectation-maximization (EM) algorithm is used as an inverse algorithm to estimate the non-stationary lung boundary. The uncertainties caused in Kalman-type filters due to inaccurate selection of model parameters are overcome using EM algorithm. Numerical experiments using chest shaped geometry are carried out with proposed method and the performance is compared with extended Kalman filter (EKF). Results show superior performance of EM in estimation of the lung boundary.

  1. Direct and indirect measures of speech articulator motions using low power EM sensors

    SciTech Connect

    Barnes, T; Burnett, G; Gable, T; Holzrichter, J F; Ng, L

    1999-05-12

    Low power Electromagnetic (EM) Wave sensors can measure general properties of human speech articulator motions, as speech is produced. See Holzrichter, Burnett, Ng, and Lea, J.Acoust.Soc.Am. 103 (1) 622 (1998). Experiments have demonstrated extremely accurate pitch measurements (< 1 Hz per pitch cycle) and accurate onset of voiced speech. Recent measurements of pressure-induced tracheal motions enable very good spectra and amplitude estimates of a voiced excitation function. The use of the measured excitation functions and pitch synchronous processing enable the determination of each pitch cycle of an accurate transfer function and, indirectly, of the corresponding articulator motions. In addition, direct measurements have been made of EM wave reflections from articulator interfaces, including jaw, tongue, and palate, simultaneously with acoustic and glottal open/close signals. While several types of EM sensors are suitable for speech articulator measurements, the homodyne sensor has been found to provide good spatial and temporal resolution for several applications.

  2. Evaluation model calculations with the water reactor analysis package (WRAP-EM)

    SciTech Connect

    Gregory, M.V.; Beranek, F.

    1982-01-01

    The Water Reactor Analysis Package-Evaluation Model (WRAP-EM) is a modular system of computer codes designed to provide the safety analyst with the capability of performing complete loss-of-coolant calculations for both pressurized- and boiling-water reactor systems. The system provides a licensing-type calculation capability and thus contains most of the Nuclear Regulatory Commission-Approved EM options, as described in the Code of Federal Regulations, Title 10, Part 50, Appendix K. All phases of an accident (blowdown, refill, and reflood) are modeled. The WRAP consists of modified versions of five preexisting codes (RELAP4/MOD5, GAPCON, FRAP, MOXY, and NORCOOL), the necessary interfaces to permit automatic transition from one code to the next during the transient calculations, plus a host of user-convenience features to aid the analyst faced with a multitude of EM calculations. The WRAP has been verified against both calculated and experimental results.

  3. Fabs enable single particle cryoEM studies of small proteins

    PubMed Central

    Wu, Shenping; Avila-Sakar, Agustin; Kim, JungMin; Booth, David S.; Greenberg, Charles H.; Rossi, Andrea; Liao, Maofu; Li, Xueming; Alian, Akram; Griner, Sarah L.; Juge, Narinobu; Yu, Yadong; Mergel, Claudia M.; Chaparro-Riggers, Javier; Strop, Pavel; Tampé, Robert; Edwards, Robert H.; Stroud, Robert M.; Craik, Charles S.; Cheng, Yifan

    2012-01-01

    Summary In spite of its recent achievements, the technique of single particle electron cryomicroscopy (cryoEM) has not been widely used to study proteins smaller than 100kDa, although it is a highly desirable application of this technique. One fundamental limitation is that images of small proteins embedded in vitreous ice do not contain adequate features for accurate image alignment. We describe a general strategy to overcome this limitation by selecting a fragment antigen binding (Fab) to form a stable and rigid complex with a target protein, thus providing a defined feature for accurate image alignment. Using this approach, we determined a three-dimensional structure of a ~65 kDa protein by single particle cryoEM. Because Fabs can be readily generated against a wide range of proteins by phage display, this approach is generally applicable to study many small proteins by single particle cryoEM. PMID:22483106

  4. Fabs enable single particle cryoEM studies of small proteins.

    PubMed

    Wu, Shenping; Avila-Sakar, Agustin; Kim, JungMin; Booth, David S; Greenberg, Charles H; Rossi, Andrea; Liao, Maofu; Li, Xueming; Alian, Akram; Griner, Sarah L; Juge, Narinobu; Yu, Yadong; Mergel, Claudia M; Chaparro-Riggers, Javier; Strop, Pavel; Tampé, Robert; Edwards, Robert H; Stroud, Robert M; Craik, Charles S; Cheng, Yifan

    2012-04-01

    In spite of its recent achievements, the technique of single particle electron cryomicroscopy (cryoEM) has not been widely used to study proteins smaller than 100 kDa, although it is a highly desirable application of this technique. One fundamental limitation is that images of small proteins embedded in vitreous ice do not contain adequate features for accurate image alignment. We describe a general strategy to overcome this limitation by selecting a fragment antigen binding (Fab) to form a stable and rigid complex with a target protein, thus providing a defined feature for accurate image alignment. Using this approach, we determined a three-dimensional structure of an ∼65 kDa protein by single particle cryoEM. Because Fabs can be readily generated against a wide range of proteins by phage display, this approach is generally applicable to study many small proteins by single particle cryoEM. PMID:22483106

  5. Physics-based simulation of EM and SM in TSV-based 3D IC structures

    SciTech Connect

    Kteyan, Armen; Sukharev, Valeriy; Zschech, Ehrenfried

    2014-06-19

    Evolution of stresses in through-silicon-vias (TSVs) and in the TSV landing pad due to the stress migration (SM) and electromigration (EM) phenomena are considered. It is shown that an initial stress distribution existing in a TSV depends on its architecture and copper fill technology. We demonstrate that in the case of proper copper annealing the SM-induced redistribution of atoms results in uniform distributions of the hydrostatic stress and concentration of vacancies along each segment. In this case, applied EM stressing generates atom migration that is characterized by kinetics depending on the preexisting equilibrium concentration of vacancies. Stress-induced voiding in TSV is considered. EM induced voiding in TSV landing pad is analyzed in details.

  6. Exploring conformational modes of macromolecular assemblies by multi-particle cryo-EM

    PubMed Central

    Spahn, Christian M.T.; Penczek, Pawel A.

    2009-01-01

    Summary Single particle cryo-electron microscopy (cryo-EM) is a technique aimed at structure determination of large macromolecular complexes in their unconstrained, physiological conditions. The power of the method has been demonstrated in selected studies where for highly symmetric molecules the resolution attained permitted backbone tracing. However, most molecular complexes appear to exhibit intrinsic conformational variability necessary to perform their functions. Therefore, it is now increasingly recognized that sample heterogeneity constitutes a major methodological challenge for cryo-EM. To overcome it dedicated experimental and particularly computational multi-particle approaches have been developed. Their applications point to the future of cryo-EM as an experimental method uniquely suited to visualize the conformational modes of large macromolecular complexes and machines. PMID:19767196

  7. Diffusion-Based EM Algorithm for Distributed Estimation of Gaussian Mixtures in Wireless Sensor Networks

    PubMed Central

    Weng, Yang; Xiao, Wendong; Xie, Lihua

    2011-01-01

    Distributed estimation of Gaussian mixtures has many applications in wireless sensor network (WSN), and its energy-efficient solution is still challenging. This paper presents a novel diffusion-based EM algorithm for this problem. A diffusion strategy is introduced for acquiring the global statistics in EM algorithm in which each sensor node only needs to communicate its local statistics to its neighboring nodes at each iteration. This improves the existing consensus-based distributed EM algorithm which may need much more communication overhead for consensus, especially in large scale networks. The robustness and scalability of the proposed approach can be achieved by distributed processing in the networks. In addition, we show that the proposed approach can be considered as a stochastic approximation method to find the maximum likelihood estimation for Gaussian mixtures. Simulation results show the efficiency of this approach. PMID:22163956

  8. An Introduction to Emergency Medical Services (EMS). Pre-Hospital Phase. Emergency Medical Services Orientation, Lesson Plan No. 9.

    ERIC Educational Resources Information Center

    Young, Derrick P.

    Designed for use with interested students at high schools, community colleges, and four-year colleges, this lesson plan was developed to provide an introduction to the pre-hospital phase of Emergency Medical Services (EMS) and to serve as a recruitment tool for the EMS Program at Kapiolani Community College (KCC) in Hawaii. The objectives of the…

  9. Factor Analysis with EM Algorithm Never Gives Improper Solutions when Sample Covariance and Initial Parameter Matrices Are Proper

    ERIC Educational Resources Information Center

    Adachi, Kohei

    2013-01-01

    Rubin and Thayer ("Psychometrika," 47:69-76, 1982) proposed the EM algorithm for exploratory and confirmatory maximum likelihood factor analysis. In this paper, we prove the following fact: the EM algorithm always gives a proper solution with positive unique variances and factor correlations with absolute values that do not exceed one, when the…

  10. EC and EM surveys of a levee of the Tuolumne River, Stanislaus County, California

    NASA Astrophysics Data System (ADS)

    Murillo, I.; Ferriz, H. D.

    2010-12-01

    The Tuolumne River Regional Park is built over a non-engineered levee, which allegedly included a portion of a 1920’s landfill. EC and EM surveys were conducted to substantiate this report. The conductivity measurements were acquired using a Geonics EM-31 MK2, Geonics EM-34, and the AGI Superstring Resistivity meters. The Geonics EM-31 MK2 acquired conductivity data in the horizontal and vertical dipole mode with theoretical penetration depths of 3 meters and 6 m respectively. The Geonics EM-34 acquired data at spacings of 10 and 20 m in both horizontal and vertical mode, with theoretical penetrations of 7.5 m, 15 m, and 30 m. The location of all electromagnetic measurements where tracked using a Trimble 114 GPS receiver. The AGI Superstring resistivity meter collected data in dipole-dipole mode over a 108-meter span with a four-meter spacing between each stake. The EM conductivity ranges from 20 mS/m to 50mS/m on the “background” portions of the levee, but the central portions of the profile include high conductivity anomalies (120 mS/m to 300 mS/m), which potentially represents the old landfill. The anomalies form “pockets” within the profile, rather than a continuous block, which leads us to believe that the profile cuts only the fringe of the landfill. Resistivity imaging confirms the presence of low resistivity materials (< 10 ohmm) at depths from 2 to 7 m, underlain by a zone of higher resistivities (20 to 80 ohmm) to a depth of 20 m. Because the area is used as a park, and is periodically irrigated, we cannot discount the possibility that some of the high conductivity/low resistivity anomalies could be related to increased water content in the soil.

  11. Recidivism Among Licensed-Released Prisoners Who Participated in the EM Program in Israel.

    PubMed

    Shoham, Efrat; Yehosha-Stern, Shirley; Efodi, Rotem

    2015-08-01

    Toward the end of 2006, a pilot program was launched in Israel wherein licensed-released prisoners were put under electronic monitoring (EM). In addition to EM, the pilot program, operated by the Prisoners' Rehabilitation Authority, provides programs of occupational supervision and personal therapy and is designed to allow for early release of those prisoners who, without increased supervision, would have been found unsuitable for early release. The aim of this study was to ascertain whether participation in the EM program among licensed-released prisoners in Israel might bring about lessened recidivism. For that matter, rates of arrests and incarceration were examined during a follow-up period of up to 4 years, among the entirety of licensed-released prisoners participating in the EM program between the years 2007 and 2009 (n = 155). To compare recidivism rates, a control group was assembled from among the entirety of released prisoners who were found unsuitable for early release in judicial conditions, and had therefore served the full term of their incarceration, to be released between the years 2005 and 2006 (a period of time during which an EM program was not yet operated among licensed-released prisoners in Israel). Study findings clearly show that while among the control group, 42% of released prisoners were re-incarcerated, at the end of a 4-year follow-up period, only 15% among the study group had returned to prison. These findings can be explained by combining the Social Control theory and the Self-Control theory which consider the period of time under EM program and the occupational and familial integration tools for reducing criminal connections and enhancing pro-social behavior. PMID:24510371

  12. Análise da medição do raio solar em ultravioleta

    NASA Astrophysics Data System (ADS)

    Saraiva, A. C. V.; Giménez de Castro, C. G.; Costa, J. E. R.; Selhorst, C. L.; Simões, P. J. A.

    2003-08-01

    A medição acurada do raio solar em qualquer banda do espectro eletromagnético é de relevância na formulação e calibração de modelos da estrutura e atmosfera solar. Esses modelos atribuem emissão do contínuo do Sol calmo em microondas à mesma região da linha Ha do Hell. Apresentamos a medição do raio solar em UV com imagens do EIT (Extreme Ultraviolet Image Telescope) entre 1996 e 2002, no comprimento de onda 30,9 nm (Ha do Hell), que se forma na região de transição/cromosfera solar. A técnica utilizada para o cálculo do raio UV foi baseada na transformada Wavelet B3spline. Fizemos um banco de dados com 1 imagem por dia durante o período citado. Obtivemos como resultado o raio médio da ordem de 975.61" e uma diminuição do mesmo para o período citado variando em média -0,45" /ano. Comparamos estes dados com os valores obtidos pelo ROI (Radio Observatório de Itapetinga) em 22/48 GHz e Nobeyama Radio Heliograph em 17 GHz mostrando que os raios médios são muito próximos o que indica que a região de formação nessas freqüências é a mesma conforme os modelos. Comparamos os resultados também com outros índices de atividade solar.

  13. Mass Gathering Medical Care: Resource Document for the National Association of EMS Physicians Position Statement.

    PubMed

    Schwartz, Brian; Nafziger, Sarah; Milsten, Andrew; Luk, Jeffrey; Yancey, Arthur

    2015-01-01

    Mass gatherings are heterogeneous in terms of size, duration, type of event, crowd behavior, demographics of the participants and spectators, use of recreational substances, weather, and environment. The goals of health and medical services should be the provision of care for participants and spectators consistent with local standards of care, protection of continuing medical service to the populations surrounding the event venue, and preparation for surge to respond to extraordinary events. Pre-event planning among jurisdictional public health and EMS, acute care hospitals, and event EMS is essential, but should also include, at a minimum, event security services, public relations, facility maintenance, communications technicians, and the event planners and organizers. Previous documented experience with similar events has been shown to most accurately predict future needs. Future work in and guidance for mass gathering medical care should include the consistent use and further development of universally accepted consistent metrics, such as Patient Presentation Rate and Transfer to Hospital Rate. Only by standardizing data collection can evaluations be performed that link interventions with outcomes to enhance evidence-based EMS services at mass gatherings. Research is needed to evaluate the skills and interventions required by EMS providers to achieve desired outcomes. The event-dedicated EMS Medical Director is integral to acceptable quality medical care provided at mass gatherings; hence, he/she must be included in all aspects of mass gathering medical care planning, preparations, response, and recovery. Incorporation of jurisdictional EMS and community hospital medical leadership, and emergency practitioners into these processes will ensure that on-site care, transport, and transition to acute care at appropriate receiving facilities is consistent with, and fully integrated into the community's medical care system, while fulfilling the needs of event

  14. Consensus among flexible fitting approaches improves the interpretation of cryo-EM data.

    PubMed

    Ahmed, Aqeel; Whitford, Paul C; Sanbonmatsu, Karissa Y; Tama, Florence

    2012-02-01

    Cryo-elecron microscopy (cryo-EM) can provide important structural information of large macromolecular assemblies in different conformational states. Recent years have seen an increase in structures deposited in the Protein Data Bank (PDB) by fitting a high-resolution structure into its low-resolution cryo-EM map. A commonly used protocol for accommodating the conformational changes between the X-ray structure and the cryo-EM map is rigid body fitting of individual domains. With the emergence of different flexible fitting approaches, there is a need to compare and revise these different protocols for the fitting. We have applied three diverse automated flexible fitting approaches on a protein dataset for which rigid domain fitting (RDF) models have been deposited in the PDB. In general, a consensus is observed in the conformations, which indicates a convergence from these theoretically different approaches to the most probable solution corresponding to the cryo-EM map. However, the result shows that the convergence might not be observed for proteins with complex conformational changes or with missing densities in cryo-EM map. In contrast, RDF structures deposited in the PDB can represent conformations that not only differ from the consensus obtained by flexible fitting but also from X-ray crystallography. Thus, this study emphasizes that a "consensus" achieved by the use of several automated flexible fitting approaches can provide a higher level of confidence in the modeled configurations. Following this protocol not only increases the confidence level of fitting, but also highlights protein regions with uncertain fitting. Hence, this protocol can lead to better interpretation of cryo-EM data. PMID:22019767

  15. Consensus among flexible fitting approaches improves the interpretation of cryo-EM data

    PubMed Central

    Ahmed, Aqeel; Whitford, Paul C.; Sanbonmatsu, Karissa Y.; Tama, Florence

    2011-01-01

    Cryo-elecron microscopy (Cryo-EM) can provide important structural information of large macromolecular assemblies in different conformational states. Recent years have seen an increase in structures deposited in the Protein Data Bank (PDB) by fitting a high-resolution structure into its low-resolution cryo-EM map. A commonly used protocol for accommodating the conformational changes between the X-ray structure and the cryo-EM map is rigid body fitting of individual domains. With the emergence of different flexible fitting approaches, there is a need to compare and revise these different protocols for the fitting. We have applied three diverse automated flexible fitting approaches on a protein dataset for which rigid domain fitting (RDF) models have been deposited in the PDB. In general, a consensus is observed in the conformations, which indicates a convergence from these theoretically different approaches to the most probable solution corresponding to the cryo-EM map. However, the result shows that the convergence might not be observed for proteins with complex conformational changes or with missing densities in cryo-EM map. In contrast, RDF structures deposited in the PDB can represent conformations that not only differ from the consensus obtained by flexible fitting but also from X-ray crystallography. Thus, this study emphasizes that a “consensus” achieved by the use of several automated flexible fitting approaches can provide a higher level of confidence in the modeled configurations. Following this protocol not only increases the confidence level of fitting, but also highlights protein regions with uncertain fitting. Hence, this protocol can lead to better interpretation of cryo-EM data. PMID:22019767

  16. EM Safety Innovations Aim Toward Safer Technologies and Better Information for Users

    SciTech Connect

    Lankford, M.; Geiger, J.; Carpenter, C.

    2002-02-26

    Beginning in 2000, the Department of Energy's Office of Environmental Management (EM), Office of Science and Technology (OST) has substantially re-examined and improved our approach to worker safety and health. Consistent with OST's responsibilities for safety, these initiatives can be categorized generally as: (1) Making our technologies inherently safer to use; and (2) Providing useful safety and health information about our technologies to the sites and technology operators. This evolved through a collaborative process by the EM Office of Safety, Health and Security, the EM Office of Science and Technology, EM Focus Areas and others. It was, initially, largely in response to a set of eight recommendations by the Environmental Management Advisory Board (EMAB) and to lessons learned from a serious accident in August, 2000 involving an OST-funded new technology. The cornerstone of this effort is the Policy for Occupational Safety and Health in EM's Science and Technology Program, issued in January 2001. DOE Focus Areas are focusing more attention on worker safety and health in their solicitations and procurement documents for new technology research and development (R&D) projects. EM Headquarters is working with Focus Areas, site environmental contractors, technology developers, and their respective DOE field organizations to ensure that roles and responsibilities for worker safety and health are clearly defined when a new technology is demonstrated at an environmental management site. The peer review process administered by the American Society of Mechanical Engineers (ASME) now requires technology developers to think through their approach to safety and health in a more detailed, focused way than previously. In Innovative Technology Summary Reports (ITSRs), developers are comparing their new technologies to baseline technologies on the basis of safety and health. Technology Safety Data Sheets (TSDSs) are being prepared for new technologies when they reach the

  17. Influence of motivations for seeking ISO 14001 certification on perceptions of EMS effectiveness in China.

    PubMed

    Fryxell, Gerald E; Lo, Carlos Wing-Hung; Chung, Shan Shan

    2004-02-01

    This study examines the motivations of mainland Chinese facilities in seeking ISO 14001 certification and examines the linkages between these motivations and self-reports of the effectiveness of major environmental management system (EMS) components. In a sample of 128 facilities in Beijing, Shanghai, and Guangzhou, the main drivers for certification were reported to be to ensure regulatory compliance, to enhance the firm's reputation, and to improve environmental performance, in that order. Although motivation to achieve cost reductions were least emphasized, a broad range of motivations appears to be considered in the decision to seek certification to ISO 14001. Regression models linking these motivations to the EMS components suggests that internal motivations have an influence on most EMS components. One interesting exception to this, however, is that no significant relationship was observed between internal motivations and the promulgation of environmental objectives and targets. The relationships associated with external motivations for certification (i.e., those in response to customer and other stakeholder pressures) and EMS components, on the other hand, are weaker and tend to occur earlier in the process cycle. No significant relationships were found between motivations to reduce costs and perceptions of the effectiveness of EMS components. Overall, these findings suggest that ISO 14001, as currently being implemented in mainland China, may have a modestly useful role when used in combination with other policy mechanisms to move the Chinese economy toward more sustainable practices. It is asserted that the ISO standard could provide even greater benefits if Chinese registrars were more proactive in developing EMS in conjunction with even more rigorous third-party audits. PMID:15285401

  18. Rotating-bed reactor as a power source for EM gun applications

    SciTech Connect

    Powell, J.; Botts, T.; Stickley, C.M.; Meth, S.

    1980-01-01

    Electromagnetic gun applications of the Rotating Bed Reactor (RBR) are examined. The RBR is a compact (approx. 1 m/sup 3/), (up to several thousand MW(th)), high-power reactor concept, capable of producing a high-temperature (up to approx. 300/sup 0/K) gas stream with a MHD generator coupled to it, the RBR can generate electric power (up to approx. 1000 MW(e)) in the pulsed or cw modes. Three EM gun applications are investigated: a rail gun thruster for orbit transfer, a rapid-fire EM gun for point defense, and a direct ground-to-space launch. The RBR appears suitable for all applications.

  19. Genomic characterization of EmsB microsatellite loci in Echinococcus multilocularis.

    PubMed

    Valot, Benoît; Knapp, Jenny; Umhang, Gérald; Grenouillet, Frédéric; Millon, Laurence

    2015-06-01

    EmsB is a molecular marker applied to Echinococcus multilocularis genotyping studies. This marker has largely been used to investigate the epidemiology of the parasite in different endemic foci. The present study has lifted the veil on the genetic structure of this microsatellite. By in silico analysis on the E. multilocularis genome the microsatellite was described in about 40 copies on the chromosome 5 of the parasite. Similar structure was found in the relative parasite Echinococcus granulosus, where the microsatellite was firstly described. The present study completes the first investigations made on the EmsB microsatellite origins and confirms the reliability of this highly discriminant molecular marker. PMID:25847697

  20. Denoising of human speech using combined acoustic and em sensor signal processing

    SciTech Connect

    Ng, L C; Burnett, G C; Holzrichter, J F; Gable, T J

    1999-11-29

    Low Power EM radar-like sensors have made it possible to measure properties of the human speech production system in real-time, without acoustic interference. This greatly enhances the quality and quantify of information for many speech related applications. See Holzrichter, Burnett, Ng, and Lea, J. Acoustic. Soc. Am. 103 (1) 622 (1998). By using combined Glottal-EM- Sensor- and Acoustic-signals, segments of voiced, unvoiced, and no-speech can be reliably defined. Real-time Denoising filters can be constructed to remove noise from the user's corresponding speech signal.

  1. Use of the AIC with the EM algorithm: A demonstration of a probability model selection technique

    SciTech Connect

    Glosup, J.G.; Axelrod M.C.

    1994-11-15

    The problem of discriminating between two potential probability models, a Gaussian distribution and a mixture of Gaussian distributions, is considered. The focus of our interest is a case where the models are potentially non-nested and the parameters of the mixture model are estimated through the EM algorithm. The AIC, which is frequently used as a criterion for discriminating between non-nested models, is modified to work with the EM algorithm and is shown to provide a model selection tool for this situation. A particular problem involving an infinite mixture distribution known as Middleton`s Class A model is used to demonstrate the effectiveness and limitations of this method.

  2. Quality assurance guidance for laboratory assessment plates in support of EM environmental sampling and analysis activities

    SciTech Connect

    Not Available

    1994-05-01

    This document is one of several guidance documents developed to support the EM (DOE Environmental Restoration and Waste Management) Analytical Services program. Its purpose is to introduce assessment plates that can be used to conduct performance assessments of an organization`s or project`s ability to meet quality goals for analytical laboratory activities. These assessment plates are provided as non-prescriptive guidance to EM-support organizations responsible for collection of environmental data for remediation and waste management programs at DOE facilities. The assessments evaluate objectively all components of the analytical laboratory process to determine their proper selection and use.

  3. Study on rheo-diecasting process of 7075R alloys by SA-EMS melt homogenized treatment

    NASA Astrophysics Data System (ADS)

    Zhihua, G.; Jun, X.; Zhifeng, Z.; Guojun, L.; Mengou, T.

    2016-03-01

    An advanced melt processing technology, spiral annular electromagnetic stirring (SA-EMS) based on the annular electromagnetic stirring (A-EMS) process was developed for manufacturing Al-alloy components with high integrity. The SA-EMS process innovatively combines non-contact electromagnetic stirring and a spiral annular chamber with specially designed profiles to in situ make high quality melt slurry, and intensive forced shearing can be achieved under high shear rate and high intensity of turbulence inside the spiral annular chamber. In this paper, the solidification microstructure and hardness of 7075R alloy die-casting connecting rod conditioned by the SA-EMS melt processing technology were investigated. The results indicate that, the SA-EMS melt processing technology exhibited superior grain refinement and remarkable structure homogeneity. In addition, it can evidently enhance the mechanical performance and reduce the crack tendency.

  4. Theoretical and FEM analysis of suspension and propulsion system with HTS hybrid electromagnets in an EMS Maglev model

    NASA Astrophysics Data System (ADS)

    Chung, Y. D.; Lee, C. Y.; Jang, J. Y.; Yoon, Y. S.; Ko, T. K.

    2011-11-01

    We have been constructed a proto-type electromagnetic suspension (EMS) based maglev vehicle system. The maglev concept utilizes magnetic forces for noncontact suspension, guidance and propulsion. The suspension system with high temperature superconducting (HTS) hybrid electromagnet (EM) is composed of HTS coils and normal coils, which consume little power to keep large suspension gap. The magnetic forces realize to guide the vehicle, propel the vehicle along the guide-way and assist in braking action. The proto-type EMS-based Maglev model is designed to keep the suspension gap of 20 mm. This paper presents the theoretical analysis of the maglev vehicle based on the EMS model to obtain the designing parameters for levitation and propulsion forces. The magnetic field distributions of the electromagnetic forces with hybrid EM and propulsion stator coils are analyzed based on three dimension (3D) finite element method (FEM) analysis. From the simulation results, appropriately design parameters of the suspension, guidance and propulsion were obtained.

  5. Preliminary Seafloor Controlled Source EM Results From APPLE

    NASA Astrophysics Data System (ADS)

    Behrens, J. P.; MacGregor, L.; Constable, S.; Everett, M.

    2001-12-01

    Certain events in the life cycle of oceanic lithosphere are dominantly two-dimensional. These include formation of crust at axial spreading centers and deformation at the lithosphere - asthenosphere boundary. These processes may result in an electrically anisotropic oceanic lithosphere by creating conductive pathways in preferred orientations. Controlled Source Electromagnetic (CSEM) soundings and Magnetotelluric (MT) soundings were made during the Anisotropy and Physics of the Pacific Lithosphere Experiment (APPLE), carried out in February/March 2001 approximately 600 km west of San Diego, California. Twenty seafloor electromagnetic field sensors were deployed: 4 long-wire CSEM recorders with 200 m electrode offsets, 6 high-frequency MT/CSEM recorders with two orthogonal 10 m offset electrodes and two orthogonal induction coil magnetometers, and 10 low-frequency MT recorders with a three-component fluxgate magnetometer and two orthogonal 10 m electric dipoles, 5 of which also recorded CSEM data. Every instrument was recovered, with data, during this primary cruise and a follow-up recovery cruise for the long-period instruments in August 2001. The deep-towed EM transmitter (DASI) was a 100 m horizontal electric dipole, which was towed in a 30 km radius circle around a central core of recorders. A radial tow was also performed. DASI transmitted a 4 Hz square wave throughout the CSEM phase of the experiment. Initial processing of the CSEM data reveals evidence of crustal anisotropy. In particular, transmitted electromagnetic energy is attenuated more strongly when propagating from west to east than from north to south. The difference in attenuation is about a factor of two, at a range of 30 km and a frequency of 4Hz. This confirms earlier results from the PEGASUS experiment, which proposed that oceanic lower crust and upper mantle with east-west trending lineaments of increased conductivity will exhibit greater attenuation of electric fields in the east

  6. Rétraction: plagiat aggravé dans l'article Aspergillose broncho-pulmonaire allergique lors d'un asthme réfractaire: à propos d'un cas clinique. Khalid Lahmadi, Hind El Youssi, Jawad Rochdi, BoughrineNawal, Er-Rami Mohammed. The Pan African Medical Journal. 2015;20:350. (doi:10.11604/pamj.2015.20.350.6572)

    PubMed Central

    2015-01-01

    Cet article retracte l'article "Aspergillose broncho-pulmonaire allergique lors d'un asthme réfractaire: à propos d'un cas clinique. Khalid Lahmadi, Hind El Youssi, Jawad Rochdi, BoughrineNawal, Er-Rami Mohammed. The Pan African Medical Journal. 2015;20:350. (doi:10.11604/pamj.2015.20.350.6572)" PMID:26401219

  7. Ensemble cryo-EM uncovers inchworm-like translocation of a viral IRES through the ribosome

    PubMed Central

    Abeyrathne, Priyanka D; Koh, Cha San; Grant, Timothy; Grigorieff, Nikolaus; Korostelev, Andrei A

    2016-01-01

    Internal ribosome entry sites (IRESs) mediate cap-independent translation of viral mRNAs. Using electron cryo-microscopy of a single specimen, we present five ribosome structures formed with the Taura syndrome virus IRES and translocase eEF2•GTP bound with sordarin. The structures suggest a trajectory of IRES translocation, required for translation initiation, and provide an unprecedented view of eEF2 dynamics. The IRES rearranges from extended to bent to extended conformations. This inchworm-like movement is coupled with ribosomal inter-subunit rotation and 40S head swivel. eEF2, attached to the 60S subunit, slides along the rotating 40S subunit to enter the A site. Its diphthamide-bearing tip at domain IV separates the tRNA-mRNA-like pseudoknot I (PKI) of the IRES from the decoding center. This unlocks 40S domains, facilitating head swivel and biasing IRES translocation via hitherto-elusive intermediates with PKI captured between the A and P sites. The structures suggest missing links in our understanding of tRNA translocation. DOI: http://dx.doi.org/10.7554/eLife.14874.001 PMID:27159452

  8. Environmental Cost Analysis System (ECAS) Status and Compliance Requirements for EM Consolidated Business Center Contracts - 13204

    SciTech Connect

    Sanford, P.C.; Moe, M.A.; Hombach, W.G.; Urdangaray, R.

    2013-07-01

    The Department of Energy (DOE) Office of Environmental Management (EM) has developed a web-accessible database to collect actual cost data from completed EM projects to support cost estimating and analysis. This Environmental Cost Analysis System (ECAS) database was initially deployed in early 2009 containing the cost and parametric data from 77 decommissioning, restoration, and waste management projects completed under the Rocky Flats Closure Project. In subsequent years we have added many more projects to ECAS and now have a total of 280 projects from 8 major DOE sites. This data is now accessible to DOE users through a web-based reporting tool that allows users to tailor report outputs to meet their specific needs. We are using it as a principal resource supporting the EM Consolidated Business Center (EMCBC) and the EM Applied Cost Engineering (ACE) team cost estimating and analysis efforts across the country. The database has received Government Accountability Office review as supporting its recommended improvements in DOE's cost estimating process, as well as review from the DOE Office of Acquisition and Project Management (APM). Moving forward, the EMCBC has developed a Special Contract Requirement clause or 'H-Clause' to be included in all current and future EMCBC procurements identifying the process that contractors will follow to provide DOE their historical project data in a format compatible with ECAS. Changes to DOE O 413.3B implementation are also in progress to capture historical costs as part of the Critical Decision project closeout process. (authors)

  9. The VLF-EM imaging of potential collapse on the LUSI embankment

    NASA Astrophysics Data System (ADS)

    Sungkono; Husein, Alwi; Prasetyo, Hardi; Bahri, Ayi S.; Monteiro Santos, Fernando A.; Santosa, Bagus J.

    2014-10-01

    Collapse and overtopping repeatedly occur in LUSI Embankment. Discontinuities (crack or fracture) in the embankment are major reasons for embankment failures or collapses. Very-low frequency electromagnetic (VLF-EM) measurement is essentially a non-destructive technique which displays subsurface 2-D cross section of resistivity. The cross section result has the possibility of detecting discontinuities and liquid saturation in embankment before it collapsed by observing which part of it in the cross section has low resistivity. This paper presents results of a survey conducted at the LUSI embankment in Eastern Java, Indonesia in a part of potential collapse. VLF-EM profiles measured along the embankment crest provided an overview of the whole embankment and served to detect anomalous zones. The noise assisted multivariate empirical mode decomposition (NA-MEMD) is applied to reject unwanted VLF-EM noise and Inv2DVLF software is applied to obtain result of 2-D resistivity models. In the selected area, the drill log and the standard penetration test (SPT) value gave detailed information about subsurface layer below embankment. This information is valuable for supporting 2-D resistivity image obtained from VLF-EM data inversion. Furthermore, the low resistivity in embankment layer is associated to discontinuities (fracture, crack or fault) along the embankment which caused its collapse.

  10. A study on techniques for and user requirements on systems integration in SCADA/EMS

    SciTech Connect

    Rahkonen, T.; Cegrell, T.

    1995-12-31

    Stating requirements on systems integration in a SCADA/EMS procurement project can be a delicate task, especially if a long-term strategy including integration with future systems is striven for. The problems are accentuated by the fact that in order to achieve a cost-efficient system utilities requirements have to be often stated, at least to some degree, with the SCADA/EMS vendors` standard systems in mind. This paper summarizes results from two state-of-the-practice studies, where among others, experienced SCADA/EMS users and vendors were investigated in terms of practical experiences from this field. The first study covered technical possibilities/problems in achieving systems integration; the focus of the second study was on specification of user requirements in industrial procurement projects. Based on the two studies, some common obstacles are recognized and some recommendations in how to state requirements on systems integration for a utility are given. The results should be of interest to utilities, vendors, and consultants in SCADA/EMS procurement projects.

  11. The testing workstation: A universal testing framework for Hydro-Quebec`s new SCADA/EMS

    SciTech Connect

    Clermont, S.; Boule, R.; Brouillette, L.; Poulin, P.

    1995-12-31

    Hydro-Quebec is in the process of renewing its Energy Management System (EMS) and its SCADA. Part of this work involves the introduction of a new data acquisition architecture. The proposed architecture requires that many systems now in operation be modified. This article describes a specialized Testing Workstation (TW) which provides all the testing capabilities needed to validate the full operation of the systems in the new communications environment. These include RTUs, other acquisition systems and even the new SCADA/EMS itself. The TW offers an extensive set of tools: communications analyzer, application data monitor, automatic and script-based simulators, allowing full testing of any system using the communications protocol of the new SCADA/EMS. The testing can be either at the communications level or at the application level. Since the TW has full database capabilities for field data, it can act both as a client (SCADA) and as a server (e.g. RTU). For Hydro-Quebec, the TW offers the advantage of standardizing the testing process used during the development of the new systems. The use of universal test equipment facilitates the integration of all systems into the new SCADA/EMS environment.

  12. Properties of the EM cascade: A tutorial utilizing high resolution 3D color graphics

    SciTech Connect

    Nelson, W R

    1987-02-01

    The fundamental interactions of electrons and photons are reviewed that are important to shower physics. The shower is then described, including a simple model, an advanced analytic model, and Monte Carlo approaches. Examples of real, as well as simulated, EM showers are discussed, and some ''rules of thumb'' are provided. (LEW)

  13. A reduced scale e.m. calorimeter prototype for the AMS-02 experiment

    NASA Astrophysics Data System (ADS)

    Cervelli, F.; Chen, G.; Coignet, G.; Di Falco, S.; Falchini, E.; Lomtadze, T.; Liu, Z.; Maestro, P.; Marrocchesi, P. S.; Paoletti, R.; Pilo, F.; Turini, N.; Valle, G.; Vannini, C.; Venanzoni, G.; Yu, Z.

    2002-09-01

    A reduced scale prototype of the Pb-SciFi sampling e.m. calorimeter for the AMS-02 experiment was tested at CERN SPS beam line X5 at energies from 5 to 250 GeV. The detector was equalized with minimum ionizing particles and calibrated with electron beams. Effective sampling thickness, linearity and energy resolution were measured.

  14. Saudi EMS Students' Perception of and Attitudes toward Their Preparedness for Disaster Management

    ERIC Educational Resources Information Center

    Alrazeeni, Daifallah

    2015-01-01

    Background: Disasters led not only to the loss of life and destruction of public infrastructures, but also resulted in consequent healthcare delivery concerns. Disaster preparedness is considered one of the key steps in emergency management. EMS students had very scanty knowledge, attitude and practices about disaster preparedness and mitigation.…

  15. Innovation on Energy Power Technology (17)Development of EMS/SCADA in TEPCO

    NASA Astrophysics Data System (ADS)

    Suzuki, Mamoru

    Effective Load Dispatching Automatic Controller (ELDAC) is an EMS/SCADA system for Central Load Dispatching Office in Tokyo Electric Power Company Inc. This paper introduces the progress of development of ELDAC, which forecasts demand, sets up the most efficient generation schedule, and controls total power from generators.

  16. The Role of Journals in Building up Communities: The Experience of "Ciência em Tela"

    ERIC Educational Resources Information Center

    Martins, Isabel; de Souza Barros, Susana

    2015-01-01

    "Ciência em Tela" is an open access Brazilian science teacher education online journal that has been published twice a year since 2008 and which encourages the participation of professionals with different backgrounds and the submission of a variety of textual genres, besides research papers. Another feature is that the journal includes…

  17. Injury risks of EMS responders: evidence from the National Fire Fighter Near-Miss Reporting System

    PubMed Central

    Taylor, Jennifer A; Davis, Andrea L; Barnes, Brittany; Lacovara, Alicia V; Patel, Reema

    2015-01-01

    Objectives We analysed near-miss and injury events reported to the National Fire Fighter Near-Miss Reporting System (NFFNMRS) to investigate the workplace hazards and safety concerns of Emergency Medical Services (EMS) responders in the USA. Methods We reviewed 769 ‘non-fire emergency event’ reports from the NFFNMRS using a mixed methods approach. We identified 185 emergency medical calls and analysed their narrative text fields. We assigned Mechanism of Near-Miss/Injury and Nature of Injury codes and then tabulated frequencies (quantitative). We coded major themes regarding work hazards and safety concerns reported by the EMS responders (qualitative). Results Of the 185 emergency medical calls, the most commonly identified Mechanisms of Near-Miss/Injury to EMS responders was Assaults, followed by Struck-by Motor Vehicle, and Motor Vehicle Collision. The most commonly identified weapon used in an assault was a firearm. We identified 5 major domains of workplace hazards and safety concerns: Assaults by Patients, Risks from Motor Vehicles, Personal Protective Equipment, Relationships between Emergency Responders, and Policies, Procedures and Practices. Conclusions Narrative text from the NFFNMRS is a rich source of data that can be analysed quantitatively and qualitatively to provide insight into near-misses and injuries sustained by EMS responders. Near-miss reporting systems are critical components for occupational hazard surveillance. PMID:26068510

  18. E-linkage at last: EMS crews linked to hospitals & discharge diagnosis.

    PubMed

    Zanka, Frank

    2012-01-01

    This project is clearly on the cutting-edge of innovations for healthcare information systems technology within time-critical environments and its deployment. The potential for improving EMS is significant. We also believe it will change the way prehospital and hospital staff view their involvement and responsibilities with each other and the involved patients. PMID:22269692

  19. An EM Algorithm for Maximum Likelihood Estimation of Process Factor Analysis Models

    ERIC Educational Resources Information Center

    Lee, Taehun

    2010-01-01

    In this dissertation, an Expectation-Maximization (EM) algorithm is developed and implemented to obtain maximum likelihood estimates of the parameters and the associated standard error estimates characterizing temporal flows for the latent variable time series following stationary vector ARMA processes, as well as the parameters defining the…

  20. DeepPicker: A deep learning approach for fully automated particle picking in cryo-EM.

    PubMed

    Wang, Feng; Gong, Huichao; Liu, Gaochao; Li, Meijing; Yan, Chuangye; Xia, Tian; Li, Xueming; Zeng, Jianyang

    2016-09-01

    Particle picking is a time-consuming step in single-particle analysis and often requires significant interventions from users, which has become a bottleneck for future automated electron cryo-microscopy (cryo-EM). Here we report a deep learning framework, called DeepPicker, to address this problem and fill the current gaps toward a fully automated cryo-EM pipeline. DeepPicker employs a novel cross-molecule training strategy to capture common features of particles from previously-analyzed micrographs, and thus does not require any human intervention during particle picking. Tests on the recently-published cryo-EM data of three complexes have demonstrated that our deep learning based scheme can successfully accomplish the human-level particle picking process and identify a sufficient number of particles that are comparable to those picked manually by human experts. These results indicate that DeepPicker can provide a practically useful tool to significantly reduce the time and manual effort spent in single-particle analysis and thus greatly facilitate high-resolution cryo-EM structure determination. DeepPicker is released as an open-source program, which can be downloaded from https://github.com/nejyeah/DeepPicker-python. PMID:27424268

  1. Data for Environmental Modeling (D4EM): Background and Applications of Data Automation

    EPA Science Inventory

    The Data for Environmental Modeling (D4EM) project demonstrates the development of a comprehensive set of open source software tools that overcome obstacles to accessing data needed by automating the process of populating model input data sets with environmental data available fr...

  2. Directly Reconstructing Principal Components of Heterogeneous Particles from Cryo-EM Images

    PubMed Central

    Tagare, Hemant D.; Kucukelbir, Alp; Sigworth, Fred J.; Wang, Hongwei; Rao, Murali

    2015-01-01

    Structural heterogeneity of particles can be investigated by their three-dimensional principal components. This paper addresses the question of whether, and with what algorithm, the three-dimensional principal components can be directly recovered from cryo-EM images. The first part of the paper extends the Fourier slice theorem to covariance functions showing that the three-dimensional covariance, and hence the principal components, of a heterogeneous particle can indeed be recovered from two-dimensional cryo-EM images. The second part of the paper proposes a practical algorithm for reconstructing the principal components directly from cryo-EM images without the intermediate step of calculating covariances. This algorithm is based on maximizing the (posterior) likelihood using the Expectation-Maximization algorithm. The last part of the paper applies this algorithm to simulated data and to two real cryo-EM data sets: a data set of the 70S ribosome with and without Elongation Factor-G (EF-G), and a data set of the inluenza virus RNA dependent RNA Polymerase (RdRP). The first principal component of the 70S ribosome data set reveals the expected conformational changes of the ribosome as the EF-G binds and unbinds. The first principal component of the RdRP data set reveals a conformational change in the two dimers of the RdRP. PMID:26049077

  3. 3D time-domain airborne EM modeling for an arbitrarily anisotropic earth

    NASA Astrophysics Data System (ADS)

    Yin, Changchun; Qi, Yanfu; Liu, Yunhe

    2016-08-01

    Time-domain airborne EM data is currently interpreted based on an isotropic model. Sometimes, it can be problematic when working in the region with distinct dipping stratifications. In this paper, we simulate the 3D time-domain airborne EM responses over an arbitrarily anisotropic earth with topography by edge-based finite-element method. Tetrahedral meshes are used to describe the abnormal bodies with complicated shapes. We further adopt the Backward Euler scheme to discretize the time-domain diffusion equation for electric field, obtaining an unconditionally stable linear equations system. We verify the accuracy of our 3D algorithm by comparing with 1D solutions for an anisotropic half-space. Then, we switch attentions to effects of anisotropic media on the strengths and the diffusion patterns of time-domain airborne EM responses. For numerical experiments, we adopt three typical anisotropic models: 1) an anisotropic anomalous body embedded in an isotropic half-space; 2) an isotropic anomalous body embedded in an anisotropic half-space; 3) an anisotropic half-space with topography. The modeling results show that the electric anisotropy of the subsurface media has big effects on both the strengths and the distribution patterns of time-domain airborne EM responses; this effect needs to be taken into account when interpreting ATEM data in areas with distinct anisotropy.

  4. Are you under stress in EMS. Understanding the slippery slope of burnout and PTSD.

    PubMed

    Collopy, Kevin T; Kivlehan, Sean M; Snyder, Scott R

    2012-10-01

    Burnout and PTSD are closely linked and often underreported in EMS. EMS classrooms do little or nothing to prepare providers for the inherent emotional stresses of emergency response and the "thick skin" culture of EMS may make many providers apprehensive about sharing their true feelings. Burnout is triggered by many of the same stresses that lead to the symptoms of PTSD and providers experiencing burnout that doesn't resolve within a few weeks may actually be experiencing PTSD. Be mindful of yourself and your fellow coworkers, particularly after a very traumatic response. And remember traumatic responses don't need to be as dramatic as Sept. 11, New Orleans after Hurricane Katrina or the Aurora, CO shootings to bother an EMS worker. In contrast, these are the calls where providers often receive the most attention. Instead, watch for the new father who just performed CPR on an infant the same age as his own, or the provider who just watched his or her friend die following a motor vehicle collision. Pay attention to yourself and colleagues, and be responsible and honest with yourself and others about when coping strategies are enough, and when they aren't. Finally, don't ever be afraid to seek help. PMID:23097838

  5. De-centralized and centralized control for realistic EMS Maglev systems

    NASA Astrophysics Data System (ADS)

    Moawad, Mohamed M. Aly M.

    A comparative study of de-centralized and centralized controllers when used with real EMS Maglev Systems is introduced. This comparison is divided into two parts. Part I is concerned with numerical simulation and experimental testing on a two ton six-magnet EMS Maglev vehicle. Levitation and lateral control with these controllers individually and when including flux feedback control in combination with these controllers to enhance stability are introduced. The centralized controller is better than the de-centralized one when the system is exposed to a lateral disturbing force such as wind gusts. The flux feedback control when combined with de-centralized or centralized controllers does improve the stability and is more resistant and robust with respect to the air gap variations. Part II is concerned with the study of Maglev vehicle-girder dynamic interaction system and the comparison between these two controllers on this typical system based on performance and ride quality achieved. Numerical simulations of the ODU EMS Maglev vehicle interacting with girder are conducted with these two different controllers. The de-centralized and centralized control for EMS Maglev systems that interact with a flexible girder provides similar ride quality. Centralized control with flux feedback could be the best controller for the ODU Maglev system when operating on girder. The centralized control will guarantee the suppression of the undesired lateral displacements; hence it will provide smoother ride quality. Flux feedback will suppress air gap variations due to the track discontinuities.

  6. Lessons in Generative Design, Publishing, and Circulation: What EM-Journal's First Year Has Taught Us

    ERIC Educational Resources Information Center

    Rosinski, Jana; Lonsdale, Chelsea; Morrison, Becky; Mueller, Derek; Nannini, Adam

    2013-01-01

    "EM-Journal" is a flexibly refereed online journal featuring writing produced by students of Eastern Michigan University. The journal showcases a variety of documents (articles, essays, reports, etc.) written and designed by students enrolled in EMU's First-Year Writing (FYW) program, in selected Writing Intensive (WI) courses affiliated with the…

  7. 6. PHOTOCOPY, FOUNDATION AND FLOOR PLAN DRAWING OF E.M. BARRACKS, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    6. PHOTOCOPY, FOUNDATION AND FLOOR PLAN DRAWING OF E.M. BARRACKS, N.C.O. AND OFFICERS QUARTERS. - NIKE Missile Base SL-40, Barracks No. 1, North end of base, southest of Basketball Court & northwest of Barracks No. 2, Hecker, Monroe County, IL

  8. Quantitative comparison of FBP, EM, and Bayesian reconstruction algorithms for the IndyPET scanner.

    PubMed

    Frese, Thomas; Rouze, Ned C; Bouman, Charles A; Sauer, Ken; Hutchins, Gary D

    2003-02-01

    We quantitatively compare filtered backprojection (FBP), expectation-maximization (EM), and Bayesian reconstruction algorithms as applied to the IndyPET scanner--a dedicated research scanner which has been developed for small and intermediate field of view imaging applications. In contrast to previous approaches that rely on Monte Carlo simulations, a key feature of our investigation is the use of an empirical system kernel determined from scans of line source phantoms. This kernel is incorporated into the forward model of the EM and Bayesian algorithms to achieve resolution recovery. Three data sets are used, data collected on the IndyPET scanner using a bar phantom and a Hoffman three-dimensional brain phantom, and simulated data containing a hot lesion added to a uniform background. Reconstruction quality is analyzed quantitatively in terms of bias-variance measures (bar phantom) and mean square error (lesion phantom). We observe that without use of the empirical system kernel, the FBP, EM, and Bayesian algorithms give similar performance. However, with the inclusion of the empirical kernel, the iterative algorithms provide superior reconstructions compared with FBP, both in terms of visual quality and quantitative measures. Furthermore, Bayesian methods outperform EM. We conclude that significant improvements in reconstruction quality can be realized by combining accurate models of the system response with Bayesian reconstruction algorithms. PMID:12716002

  9. New Jersey's EMS response to Superstorm Sandy: a case study of the emergency management assistance compact.

    PubMed

    Clancy, Terry; Christensen, Kenneth; Cortacans, Henry P

    2014-06-01

    In the United States, understanding the Emergency Management Assistance Compact (EMAC) is critical to responding to a natural disaster or manmade event. Recently, the State of New Jersey responded to Superstorm Sandy and implemented the EMAC system by requesting ambulances to aid in the Emergency Medical Services response. New Jersey's response to Superstorm Sandy was unprecedented in that this storm affected the entire state and EMS community. New Jersey's EMS community and infrastructure were impacted greatly, despite years of planning and preparation for such an event. Once received, out-of-state EMS resources were integrated into New Jersey's emergency management and EMS systems. In this report, each phase of the EMAC in New Jersey is explored, from how the response was coordinated to how it ultimately was executed. The state coordinated its response on multiple levels and, as such, tested the practical applicability of the EMAC process and employed best practices and solutions to issues that arose. These best practices and solutions may prove invaluable for any state or territory that may activate the EMAC system for emergency medical service resources. PMID:24844291

  10. EmPOWERing Children with Learning Disabilities: A Practitioner-Based Reflection

    ERIC Educational Resources Information Center

    Cass, Richard J.

    2011-01-01

    Recent reports indicate that the expressive writing needs of students who struggle have become a critical and life-influencing problem. This article provides an overview of current research on the writing needs of students with LD and a practitioner-based reflection on the Singer and Bashir EmPOWER approach, a resource that can help teachers meet…

  11. Nhs: Network-based Hierarchical Segmentation for Cryo-EM Density Maps

    PubMed Central

    Burger, Virginia; Chennubhotla, Chakra

    2012-01-01

    Electron cryo-microscopy (cryo-EM) experiments yield low-resolution (3–30Å) 3D-density maps of macromolecules. These density maps are segmented to identify structurally distinct proteins, protein domains, and sub-units. Such partitioning aids the inference of protein motions and guides fitting of high-resolution atomistic structures. Cryo-EM density map segmentation has traditionally required tedious and subjective manual partitioning or semi-supervised computational methods, while validation of resulting segmentations has remained an open problem in this field. Our network-based bias-free segmentation method for cryo-EM density map segmentation, Nhs (Network-based hierarchical segmentation), provides the user with a multi-scale partitioning, reflecting local and global clustering, while requiring no user input. This approach models each map as a graph, where map voxels constitute nodes and edges connect neighboring voxels. Nhs initiates Markov diffusion (or random walk) on the weighted graph. As Markov probabilities homogenize through diffusion, an intrinsic segmentation emerges. We validate the segmentations with ground-truth maps based on atomistic models. When implemented on density maps in the 2010 Cryo-EM Modeling Challenge, Nhs efficiently and objectively partitions macromolecules into structurally and functionally relevant sub-regions at multiple scales. PMID:22696408

  12. Estimation of Item Response Models Using the EM Algorithm for Finite Mixtures.

    ERIC Educational Resources Information Center

    Woodruff, David J.; Hanson, Bradley A.

    This paper presents a detailed description of maximum parameter estimation for item response models using the general EM algorithm. In this paper the models are specified using a univariate discrete latent ability variable. When the latent ability variable is discrete the distribution of the observed item responses is a finite mixture, and the EM…

  13. EMS runs for suspected opioid overdose: Implications for surveillance and prevention

    PubMed Central

    Knowlton, Amy; Weir, Brian; Hazzard, Frank; Olsen, Yngvild; McWilliams, Junette; Fields, Julie; Gaasch, Wade

    2013-01-01

    Objective Opioid (including prescription opiate) abuse and overdose rates in the US have surged in the past decade. The dearth and limitations of opioid abuse and overdose surveillance systems impede the development of interventions to address this epidemic. We explored evidence to support the validity of emergency medical services (EMS) data on naloxone administration as a possible proxy for estimating incidence of opioid overdose. Methods We reviewed data from Baltimore City Fire Department EMS patient records matched with dispatch records over a thirteen month time period (2008-2009), and census 2008 data. We calculated incidence rates and patient demographic and temporal patterns of naloxone administration, and examined patient evaluation data associated with naloxone administration. Results were compared to the demographic distributions of the EMS patient and city population and to prior study findings. Results Of 116,910 EMS incidents during the study period for patients 15 years and older, EMS providers administered naloxone 1,297 times (1.1% of incidents), an average of 100 administrations per month. Overall incidence was 1.87 administrations per 1,000 population per year. Findings indicated naloxone administration peaked in summer months (31% of administrations), weekends (32%), and late afternoon (4-5:00pm [8%]); and there was a trend toward peaking in the first week of the month. The incidence of suspected opioid overdose was highest among males, whites, and those in the 45-54 year age group. Findings on temporal patterns were comparable to findings from prior studies. Demographic patterns of suspected opioid overdose were similar to medical examiner reports of demographic patterns of fatal drug or alcohol related overdoses in Baltimore in 2008-9 (88% of which involved opioids). The findings on patient evaluation data suggest some inconsistencies with previously recommended clinical indications of opioid overdose. Conclusions While our findings suggest

  14. Quality assurance guidance for field sampling and measurement assessment plates in support of EM environmental sampling and analysis activities

    SciTech Connect

    Not Available

    1994-05-01

    This document is one of several guidance documents developed by the US Department of Energy (DOE) Office of Environmental Restoration and Waste Management (EM). These documents support the EM Analytical Services Program (ASP) and are based on applicable regulatory requirements and DOE Orders. They address requirements in DOE Orders by providing guidance that pertains specifically to environmental restoration and waste management sampling and analysis activities. DOE 5700.6C Quality Assurance (QA) defines policy and requirements to establish QA programs ensuring that risks and environmental impacts are minimized and that safety, reliability, and performance are maximized. This is accomplished through the application of effective management systems commensurate with the risks imposed by the facility and the project. Every organization supporting EM`s environmental sampling and analysis activities must develop and document a QA program. Management of each organization is responsible for appropriate QA program implementation, assessment, and improvement. The collection of credible and cost-effective environmental data is critical to the long-term success of remedial and waste management actions performed at DOE facilities. Only well established and management supported assessment programs within each EM-support organization will enable DOE to demonstrate data quality. The purpose of this series of documents is to offer specific guidance for establishing an effective assessment program for EM`s environmental sampling and analysis (ESA) activities.

  15. An optically scanned EMS reporting form and analysis system for statewide use: development and five years' experience.

    PubMed

    Joyce, S M; Brown, D E

    1991-12-01

    Analysis of emergency medical services (EMS) systems data is crucial to planning, education, research, and quality assurance programs. Currently, comparative analysis of EMS data between regions or states is virtually impossible due to wide variations in data collection and analysis methods. To devise a practical and uniform EMS reporting system, we referenced the minimum data set (MDS) established by the federal government in 1974 and surveyed 22 states known to be using uniform reporting systems. In developing our final data set, elements were added based on inclusion in the MDS, national survey results, a review of current EMS literature, and consensus of local EMS providers. This set of 48 elements then was incorporated into a reporting form using narrative and optically scanned formats, allowing automated data collection for computer analysis. After a pilot study, the system was improved to allow high-speed ink reading and large volume data storage and analysis using a microcomputer. This system has subsequently been adopted by seven states. The combined data base exceeds 250,000 cases. Error screening algorithms ensure data integrity and are also used for quality assurance. Customized output reports can be generated within minutes and have assisted in EMS quality assurance, planning, and research. We believe that the successful performance of this system supports the use of the suggested data elements as well as optical scanning and microcomputer analysis of EMS data. PMID:1746736

  16. Determining and Prioritizing the Organizational Determinants of Emergency Medical Services (EMS) in Iran

    PubMed Central

    Bahadori, Mohammadkarim; Ravangard, Ramin

    2013-01-01

    Background Improving the organization of pre-hospital emergency to provide emergency medical services (EMS), as a part of health system, plays an important role in timely and properly response to incidents, as well as, reducing mortalities and disabilities. Objective This study was conducted to determine the organizational determinants of emergency medical services in Iran and analyze their relationship and prioritize them. Materials and Methods The present study is kind of descriptive and cross-sectional study that has been conducted on the first half of 2010 using DEMATEL method (a group decision-making technique). Required data were collected using a questionnaire from a sample of 30 Iranian experts in pre-hospital emergency, who were selected using available sampling method. Results The determinants of establishing an independent EMS organization as a policy maker and observer organization, providing services through public organizations such as Emergency 115, private organizations partnership in pre-hospital emergency system, and integrating pre-hospital and hospital emergency under single supervision and management were determined as organizational determinants. Also, establishing an independent EMS organization and integrating pre-hospital and hospital emergency under single supervision and management were determined as the most affecting and affected organizational determinants, respectively, with the coordinates (1.01 and 1.01) and (0.85 and - 0.85) in the pre-hospital emergency organizational determinants graph. Conclusions Emergency medical services should be considered as a system with its independent components. Establishing an independent EMS organization, integrating pre-hospital and hospital emergency under single supervision and management, as well as, extending the possibility of providing EMS through private sector are essential in order to make fundamental reforms in providing emergency medical services in Iran. PMID:24083003

  17. Measurement of EM Field Inside a Cruising Aircraft: Potential Problems for the Use of Mobile Phones on Board

    NASA Astrophysics Data System (ADS)

    Kohmura, A.; Picard, J.; Yonemoto, N.; Yamamoto, K.

    Electromagnetic (EM) emissions from portable electronic devices (PEDs) carried onboard aircraft can interfere with avionic systems. Several onboard systems using EM waves have been planned, such as mobile communications and UWB (ultra-wideband) entertainment services distribution. Manufacturers of this system develop schemes to avoid electromagnetic interference by the transmissions (emissions) of mobile phones with avionic systems; some local-specific problems still remain. The purpose of this chapter is to investigate to what extent non-GSM transmissions from the ground base stations reach inside a cruising aircraft. The EM field at the base station frequency bands is measured in a cruising small aircraft.

  18. National Energy Efficiency Evaluation, Measurement and Verification (EM&V) Standard: Scoping Study of Issues and Implementation Requirements

    SciTech Connect

    Schiller Consulting, Inc.; Schiller, Steven R.; Goldman, Charles A.; Galawish, Elsia

    2011-02-04

    This report is a scoping study that identifies issues associated with developing a national evaluation, measurement and verification (EM&V) standard for end-use, non-transportation, energy efficiency activities. The objectives of this study are to identify the scope of such a standard and define EM&V requirements and issues that will need to be addressed in a standard. To explore these issues, we provide and discuss: (1) a set of definitions applicable to an EM&V standard; (2) a literature review of existing guidelines, standards, and 'initiatives' relating to EM&V standards as well as a review of 'bottom-up' versus 'top-down' evaluation approaches; (3) a summary of EM&V related provisions of two recent federal legislative proposals (Congressman Waxman's and Markey's American Clean Energy and Security Act of 2009 and Senator Bingaman's American Clean Energy Leadership Act of 2009) that include national efficiency resource requirements; (4) an annotated list of issues that that are likely to be central to, and need to be considered when, developing a national EM&V standard; and (5) a discussion of the implications of such issues. There are three primary reasons for developing a national efficiency EM&V standard. First, some policy makers, regulators and practitioners believe that a national standard would streamline EM&V implementation, reduce costs and complexity, and improve comparability of results across jurisdictions; although there are benefits associated with each jurisdiction setting its own EM&V requirements based on their specific portfolio and evaluation budgets and objectives. Secondly, if energy efficiency is determined by the US Environmental Protection Agency to be a Best Available Control Technology (BACT) for avoiding criteria pollutant and/or greenhouse gas emissions, then a standard can be required for documenting the emission reductions resulting from efficiency actions. The third reason for a national EM&V standard is that such a standard is

  19. 2009 DOE-EM LONG-TERM MONITORING TECHNICAL FORUM SUMMARY REPORT

    SciTech Connect

    Mayer, J.

    2009-09-30

    The U. S. Department of Energy's (DOE) Office of Environmental Management (EM) has the responsibility for cleaning up 60 sites in 22 states that were associated with the legacy of the nation's nuclear weapons program and other research and development activities. These sites are unique and many of the technologies needed to successfully disposition the associated wastes have yet to be developed or would require significant re-engineering to be adapted for future EM cleanup efforts. In 2008, the DOE-EM Engineering and Technology Program (EM-22) released the Engineering and Technology Roadmap in response to Congressional direction and the need to focus on longer term activities required for the completion of the aforementioned cleanup program. One of the strategic initiatives included in the Roadmap was to enhance long term performance monitoring as defined by 'Develop and deploy cost effective long-term strategies and technologies to monitor closure sites (including soil, groundwater, and surface water) with multiple contaminants (organics, metals and radionuclides) to verify integrated long-term cleanup performance'. To support this long-term monitoring (LTM) strategic initiative, EM 22 and the Savannah River National Laboratory (SRNL) organized and held an interactive symposia, known as the 2009 DOE-EM Long-Term Monitoring Technical Forum, to define and prioritize LTM improvement strategies and products that could be realized within a 3 to 5 year investment time frame. This near-term focus on fundamental research would then be used as a foundation for development of applied programs to improve the closure and long-term performance of EM's legacy waste sites. The Technical Forum was held in Atlanta, GA on February 11-12, 2009, and attended by 57 professionals with a focus on identifying those areas of opportunity that would most effectively advance the transition of the current practices to a more effective strategy for the LTM paradigm. The meeting format

  20. 200 city survey. JEMS 2001 annual report on EMS operational & clinical trends in large, urban areas.

    PubMed

    Cady, Geoff

    2002-02-01

    This year's survey offered examples of evolving partnerships between the public and EMS providers with a growing number of systems implementing PAD programs. The apparent influence of a communication center's managing agency on prioritization strategies is concerning. However, further study is needed. EMS managers must pay careful attention to comm center practices and technology to ensure their ability to support response prioritization and the efficient management of EMS resources. The small reduction in the use of hot response (lights and siren) to every request for service is disappointing in light of medical literature and position statements that condemn this practice. Resource response can be safely prioritized using today's EMD protocol systems. Prioritization and changing response [figure: see text] time requirements to address impending revenue and service demand changes will require additional standardization of methodologies and reporting of response times to relate this measure to other system performance indicators (e.g., patient morbidity/mortality, cost, customer satisfaction, etc.). The future presents a difficult road for system administrators. However, the adoption of a growing number of information-management tools and changes in procedures and dispatch processes offer potential solutions. The increased use of hand-held computers or personal digital assistant (PDAs) to gather and provide information and the almost universal use of CAD will aid providers in performing the research necessary to change response time performance requirements, improving EMS system efficiency. Use of this technology will also likely improve patient care and reimbursement through more timely and accurate reporting and analysis. The medical director's role will be critical to ensuring potential changes don't compromise patient care. Obtaining a better understanding of how much time can safely elapse between the time of the 9-1-1 call and when patient-care activities

  1. BSSDATA - um programa otimizado para filtragem de dados em radioastronomia solar

    NASA Astrophysics Data System (ADS)

    Martinon, A. R. F.; Sawant, H. S.; Fernandes, F. C. R.; Stephany, S.; Preto, A. J.; Dobrowolski, K. M.

    2003-08-01

    A partir de 1998, entrou em operação regular no INPE, em São José dos Campos, o Brazilian Solar Spectroscope (BSS). O BSS é dedicado às observações de explosões solares decimétricas com alta resolução temporal e espectral, com a principal finalidade de investigar fenômenos associados com a liberação de energia dos "flares" solares. Entre os anos de 1999 e 2002, foram catalogadas, aproximadamente 340 explosões solares classificadas em 8 tipos distintos, de acordo com suas características morfológicas. Na análise detalhada de cada tipo, ou grupo, de explosões solares deve-se considerar a variação do fluxo do sol calmo ("background"), em função da freqüência e a variação temporal, além da complexidade das explosões e estruturas finas registradas superpostas ao fundo variável. Com o intuito de realizar tal análise foi desenvolvido o programa BSSData. Este programa, desenvolvido em linguagem C++, é constituído de várias ferramentas que auxiliam no tratamento e análise dos dados registrados pelo BSS. Neste trabalho iremos abordar as ferramentas referentes à filtragem do ruído de fundo. As rotinas do BSSData para filtragem de ruído foram testadas nos diversos grupos de explosões solares ("dots", "fibra", "lace", "patch", "spikes", "tipo III" e "zebra") alcançando um bom resultado na diminuição do ruído de fundo e obtendo, em conseqüência, dados onde o sinal torna-se mais homogêneo ressaltando as áreas onde existem explosões solares e tornando mais precisas as determinações dos parâmetros observacionais de cada explosão. Estes resultados serão apresentados e discutidos.

  2. EM23, A Natural Sesquiterpene Lactone from Elephantopus mollis, Induces Apoptosis in Human Myeloid Leukemia Cells through Thioredoxin- and Reactive Oxygen Species-Mediated Signaling Pathways

    PubMed Central

    Li, Hongyu; Li, Manmei; Wang, Guocai; Shao, Fangyuan; Chen, Wenbo; Xia, Chao; Wang, Sheng; Li, Yaolan; Zhou, Guangxiong; Liu, Zhong

    2016-01-01

    Elephantopus mollis (EM) is a traditional herbal medicine with multiple pharmacological activities. However, the efficacy of EM in treating human leukemia is currently unknown. In the current study, we report that EM23, a natural sesquiterpene lactone isolated from EM, inhibits the proliferation of human chronic myeloid leukemia (CML) K562 cells and acute myeloid leukemia (AML) HL-60 cells by inducing apoptosis. Translocation of membrane-associated phospholipid phosphatidylserines, changes in cell morphology, activation of caspases, and cleavage of PARP were concomitant with this inhibition. The involvement of the mitochondrial pathway in EM23-mediated apoptosis was suggested by observed disruptions in mitochondrial membrane potential. Mechanistic studies indicated that EM23 caused a marked increase in the level of reactive oxygen species (ROS). Pretreatment with N-acetyl-L-cysteine, a ROS scavenger, almost fully reversed EM23-mediated apoptosis. In EM23-treated cells, the expression levels of thioredoxin (Trx) and thioredoxinreductase (TrxR), two components of the Trx system involved in maintaining cellular redox homeostasis, were significantly down-regulated. Concomitantly, Trx regulated the activation of apoptosis signal-regulating kinase 1 (ASK1) and its downstream regulatory targets, the p38, JNK, and ERK MAPKs. EM23-mediated activation of ASK1/MAPKs was significantly inhibited in the presence of NAC. Furthermore, tumor necrosis factor alpha (TNF-α)-mediated activation of nuclear factor-κB (NF-κB) was suppressed by EM23, as suggested by the observed blockage of p65 nuclear translocation, phosphorylation, and reversion of IκBα degradation following EM23 treatment. Taken together, these results provide important insights into the anticancer activities of the EM component EM23 against human CML K562 cells and AML HL-60 cells. PMID:27064563

  3. EM23, A Natural Sesquiterpene Lactone from Elephantopus mollis, Induces Apoptosis in Human Myeloid Leukemia Cells through Thioredoxin- and Reactive Oxygen Species-Mediated Signaling Pathways.

    PubMed

    Li, Hongyu; Li, Manmei; Wang, Guocai; Shao, Fangyuan; Chen, Wenbo; Xia, Chao; Wang, Sheng; Li, Yaolan; Zhou, Guangxiong; Liu, Zhong

    2016-01-01

    Elephantopus mollis (EM) is a traditional herbal medicine with multiple pharmacological activities. However, the efficacy of EM in treating human leukemia is currently unknown. In the current study, we report that EM23, a natural sesquiterpene lactone isolated from EM, inhibits the proliferation of human chronic myeloid leukemia (CML) K562 cells and acute myeloid leukemia (AML) HL-60 cells by inducing apoptosis. Translocation of membrane-associated phospholipid phosphatidylserines, changes in cell morphology, activation of caspases, and cleavage of PARP were concomitant with this inhibition. The involvement of the mitochondrial pathway in EM23-mediated apoptosis was suggested by observed disruptions in mitochondrial membrane potential. Mechanistic studies indicated that EM23 caused a marked increase in the level of reactive oxygen species (ROS). Pretreatment with N-acetyl-L-cysteine, a ROS scavenger, almost fully reversed EM23-mediated apoptosis. In EM23-treated cells, the expression levels of thioredoxin (Trx) and thioredoxinreductase (TrxR), two components of the Trx system involved in maintaining cellular redox homeostasis, were significantly down-regulated. Concomitantly, Trx regulated the activation of apoptosis signal-regulating kinase 1 (ASK1) and its downstream regulatory targets, the p38, JNK, and ERK MAPKs. EM23-mediated activation of ASK1/MAPKs was significantly inhibited in the presence of NAC. Furthermore, tumor necrosis factor alpha (TNF-α)-mediated activation of nuclear factor-κB (NF-κB) was suppressed by EM23, as suggested by the observed blockage of p65 nuclear translocation, phosphorylation, and reversion of IκBα degradation following EM23 treatment. Taken together, these results provide important insights into the anticancer activities of the EM component EM23 against human CML K562 cells and AML HL-60 cells. PMID:27064563

  4. Analysis incorporating electric conductivity and magnetic permeability on loop-loop EM data for detecting the magnetite ore body

    NASA Astrophysics Data System (ADS)

    Choi, Jihyang; Yi, Myeong-Jong; Son, Jeong-Sul; Kim, Jung-Ho; Park, Sam-Gyu

    2013-04-01

    As the price of mineral resources goes up, exploring small amount of mineral deposits, which have been considered non-economic in the past, is getting more economic. Loop-loop EM survey system can be the best choice for exploring small mineral mines because no ground contact is required and portable loops are freely positioned. EM responses are affected by electric conductivity, magnetic permeability and electric permittivity. In many cases, variation ranges of latter two components are so small and ignorable. However, changes of magnetic permeability affect the data in a serious way. Multidimensional EM inversion technique incorporating both electric conductivity and magnetic susceptibility is on the developing stage. EM responses are calculated in a model of layered earth embedding a magnetic anomaly. Considering the size of the reactions, changes of relative magnetic permeability are frequency-independent effects that can be seen as static. Loop-loop EM survey using PROMIS system was conducted on a small magnetite mine. Inversion with and without considering magnetic permeability was conducted for EM data with multi-frequency and multi-separation between a transmitter and a receiver. Ferromagnetic anomalous feature was distinguishable from the subsurface media, though, enhancement by incorporating magnetic permeability was not sufficiently noticeable.

  5. High-Resolution Macromolecular Structure Determination by MicroED, a cryo-EM Method.

    PubMed

    Rodriguez, J A; Gonen, T

    2016-01-01

    Microelectron diffraction (MicroED) is a new cryo-electron microscopy (cryo-EM) method capable of determining macromolecular structures at atomic resolution from vanishingly small 3D crystals. MicroED promises to solve atomic resolution structures from even the tiniest of crystals, less than a few hundred nanometers thick. MicroED complements frontier advances in crystallography and represents part of the rebirth of cryo-EM that is making macromolecular structure determination more accessible for all. Here we review the concept and practice of MicroED, for both the electron microscopist and crystallographer. Where other reviews have addressed specific details of the technique (Hattne et al., 2015; Shi et al., 2016; Shi, Nannenga, Iadanza, & Gonen, 2013), we aim to provide context and highlight important features that should be considered when performing a MicroED experiment. PMID:27572734

  6. The 3.8 Å resolution cryo-EM structure of Zika virus.

    PubMed

    Sirohi, Devika; Chen, Zhenguo; Sun, Lei; Klose, Thomas; Pierson, Theodore C; Rossmann, Michael G; Kuhn, Richard J

    2016-04-22

    The recent rapid spread of Zika virus and its unexpected linkage to birth defects and an autoimmune neurological syndrome have generated worldwide concern. Zika virus is a flavivirus like the dengue, yellow fever, and West Nile viruses. We present the 3.8 angstrom resolution structure of mature Zika virus, determined by cryo-electron microscopy (cryo-EM). The structure of Zika virus is similar to other known flavivirus structures, except for the ~10 amino acids that surround the Asn(154) glycosylation site in each of the 180 envelope glycoproteins that make up the icosahedral shell. The carbohydrate moiety associated with this residue, which is recognizable in the cryo-EM electron density, may function as an attachment site of the virus to host cells. This region varies not only among Zika virus strains but also in other flaviviruses, which suggests that differences in this region may influence virus transmission and disease. PMID:27033547

  7. Considerations for safe EMS transport of patients infected with Ebola virus.

    PubMed

    Lowe, John J; Jelden, Katelyn C; Schenarts, Paul J; Rupp, Lloyd E; Hawes, Kingdon J; Tysor, Benjamin M; Swansiger, Raymond G; Schwedhelm, Shelly S; Smith, Philip W; Gibbs, Shawn G

    2015-01-01

    The Nebraska Biocontainment Unit through the Nebraska Medical Center in Omaha, Nebraska, recently received patients with confirmed Ebola virus from West Africa. The Nebraska Biocontainment Unit and Omaha Fire Department's emergency medical services (EMS) coordinated patient transportation from airport to the high-level isolation unit. Transportation of these highly infectious patients capitalized on over 8 years of meticulous planning and rigorous infection control training to ensure the safety of transport personnel as well as the community during transport. Although these transports occurred with advanced notice and after confirmed Ebola virus disease (EVD) diagnosis, approaches and key lessons acquired through this effort will advance the ability of any EMS provider to safely transport a confirmed or suspected patient with EVD. Three critical areas have been identified from our experience: ambulance preparation, appropriate selection and use of personal protective equipment, and environmental decontamination. PMID:25380073

  8. Comparing EM Models to RCS Measurements for Building-Penetration Radar

    SciTech Connect

    Fasenfest, B; Ueberschaer, R

    2007-05-18

    For the DARPA VisiBuilding program, SRI International and Lawrence Livermore National Laboratory are using a variety of electromagnetic (EM) simulation codes and measurement techniques to analyze how radar pulses interact with building structures and materials. Of primary interest is how interior wall and corner reflections are delayed, attenuated, and dispersed by the exterior wall materials. In this paper, we compare microwave frequency-domain radar cross section (RCS) chamber measurements of scale models of simple buildings to finite-element and finite-difference full-wave time-domain and ray-tracing models. The ability to accurately reconstruct the building from these models is compared with the reconstruction from chamber measurements. We observe that careful attention to the spatial sampling in the EM models is essential to achieving good reconstruction at the higher frequencies.

  9. Automatic CT Brain Image Segmentation Using Two Level Multiresolution Mixture Model of EM

    NASA Astrophysics Data System (ADS)

    Jiji, G. Wiselin; Dehmeshki, Jamshid

    2014-04-01

    Tissue classification in computed tomography (CT) brain images is an important issue in the analysis of several brain dementias. A combination of different approaches for the segmentation of brain images is presented in this paper. A multi resolution algorithm is proposed along with scaled versions using Gaussian filter and wavelet analysis that extends expectation maximization (EM) algorithm. It is found that it is less sensitive to noise and got more accurate image segmentation than traditional EM. Moreover the algorithm has been applied on 20 sets of CT of the human brain and compared with other works. The segmentation results show the advantages of the proposed work have achieved more promising results and the results have been tested with Doctors.

  10. Speech Articulator and User Gesture Measurements Using Micropower, Interferometric EM-Sensors

    SciTech Connect

    Holzrichter, J F; Ng, L C

    2001-02-06

    Very low power, GHz frequency, ''radar-like'' sensors can measure a variety of motions produced by a human user of machine interface devices. These data can be obtained ''at a distance'' and can measure ''hidden'' structures. Measurements range from acoustic induced, 10-micron amplitude vibrations of vocal tract tissues, to few centimeter human speech articulator motions, to meter-class motions of the head, hands, or entire body. These EM sensors measure ''fringe motions'' as reflected EM waves are mixed with a local (homodyne) reference wave. These data, when processed using models of the system being measured, provide real time states of interface positions or other targets vs. time. An example is speech articulator positions vs. time in the user's body. This information appears to be useful for a surprisingly wide range of applications ranging from speech coding synthesis and recognition, speaker or object identification, noise cancellation, hand or head motions for cursor direction, and other applications.

  11. Helicopter EMS Transport Outcomes Literature: Annotated Review of Articles Published 2007–2011

    PubMed Central

    Brown, Brandon S.; Pogue, Korby A.; Williams, Emily; Hatfield, Jesse; Thomas, Matthew; Arthur, Annette; Thomas, Stephen H.

    2012-01-01

    Helicopter EMS (HEMS) and its possible association with outcomes improvement continues to be a subject of discussion. As is the case with other scientific discourse, debate over HEMS usefulness should be framed around an evidence-based assessment of the relevant literature. In an effort to facilitate the academic pursuit of assessment of HEMS utility, in late 2000 the National Association of EMS Physicians' (NAEMSP) Air Medical Task Force prepared annotated bibliographies of the HEMS-related outcomes literature. As a result of that work, two review articles, one covering HEMS use in nontrauma and the other in trauma, published in 2002 in Prehospital Emergency Care surveyed HEMS outcomes-related literature published between 1980 and mid-2000. The project was extended with two subsequent reviews covering the literature through 2006. This review continues the series, outlining outcomes-associated HEMS literature for the three-year period 2007 through the first half of 2011. PMID:22288016

  12. Autonomic dysreflexia: one more way EMS can positively affect patient survival.

    PubMed

    Tomassoni, Paul J; Campagnolo, Denise I

    2003-12-01

    Autonomic dysreflexia is a life-threatening medical condition that affects people with spinal cord injuries above T6. Caused by the division of the autonomic nervous system, it can result in disastrous hypertension. Although complicated in nature, AD can be quickly treated and reversed by prehospital providers. The prompt emptying of a patient's bladder and/or bowels will resolve most occurrences. Other factors that can't be resolved in the prehospital setting may cause AD. In these situations, quickly transport the patient to a definitive care facility and consider the use of antihypertensive agents. Bladder catheterization and digital bowel emptying are not everyday EMS skills. They are, however, skills within the range of EMS abilities. Providers should contact their medical directors or training supervisors to obtain the training necessary to carry out both techniques. Having these skills will arm you with the necessary abilities to mitigate an episode of autonomic dysreflexia. PMID:14699347

  13. Use of the AIC with the EM algorithm: A demonstration of a probability model selection technique

    SciTech Connect

    Glosup, J.G.; Axelrod, M.C.

    1994-08-12

    The problem of discriminating between two potential probability models, a Gaussian distribution and a mixture of Gaussian distributions, is considered. The focus of interest is a case where the models are potentially non-nested and the parameters of the mixture model are estimated through the EM algorithm. The AIC, which is frequently used as a criterion for discriminating between non-nested models, is modified to work with the EM algorithm and is shown to provide a model selection tool for this situation. A particular problem involving an infinite mixture distribution known as Middleton`s Class A model is used to demonstrate the effectiveness and limitations of this method. The problem involves a probability model for underwater noise due to distant shipping.

  14. Crosshole EM for oil field characterization and EOR monitoring: Field examples

    SciTech Connect

    Wilt, M.; Schenkel, C.; Lee, K.; Torrses-Verdin, C.; Tseng, H.

    1994-12-31

    Crosshole and surface-to-borehole electromagnetic (EM) imaging is applied to reservoir characterization and steam flood monitoring in a central California oil field. Steam was injected into 3 stacked eastward dipping unconsolidated oil sands. EM measurements were made from two fiberglass-cased observation wells straddling the steam injector on a northeast-southwest profile. Field data were collected before the initiation of a steam drive to map the distribution of the oil sands and then six months after the steam was injected to monitor the progress of the steam chest. Resistivity images derived from the collected data could clearly delineate the distribution and dipping structure on the target oil sands. Difference images from data collected before and after steam flooding indicate that the steam chest has developed only in the deeper oil sands and it has preferentially migrated eastward.

  15. 3D EM imaging from a single borehole; a numerical feasibility study

    SciTech Connect

    Alumbaugh, D.L.; Wilt, M.J.

    1998-07-01

    Often the drilling of an oil well is followed by a logging process to characterize the region immediately surrounding the well bore. The electromagnetic (EM) induction tool, which provides the formation resistivity, is among the most frequently run logs. A preliminary study has been conducted to analyze the feasibility of three dimensional (3D) electromagnetic (EM) imaging from a single borehole. The logging tool consists of a vertical magnetic dipole source and multiple 3 component magnetic field receivers offset at different distances from the source. Synthetic data calculated with a 3D finite difference code demonstrate that the phase of the horizontal magnetic fields provides the critical information on the three dimensionality of the medium. A 3D inversion algorithm is then employed to demonstrate the plausibility of 3D inversion using 3 component magnetic field data. Finally, problems associated with introducing biased noise into the horizontal components of the field through misalignment of the logging tool is discussed.

  16. Simulation of Microstructure Influence on EM-Induced Degradation in Cu Interconnects

    SciTech Connect

    Sukharev, V.

    2006-02-07

    Physically based simulations are used to predict an electromigration (EM) induced void nucleation and growth in dual-inlaid copper interconnects. In this model all important atom migration driving forces are incorporated into the mass balance equation. EM-induced degradation in an interconnect segment, which is characterized by different dominant channels for mass transport, is simulated by means of a coupled solution of the continuity equation and the electromagnetics and elasticity problems. Employment of the modified phase field method into the simulation scheme provides a capability to predict realistic locations for void nucleation as well its evolution. Vacancy generation/recombination kinetics is implemented into the model. It is shown that grain boundary (GB) and interface presence effects stress distribution by acting as the additional distributed source of vacancy generation-annihilation as well as by providing additional channels for vacancy-migration-induced stress relaxation.

  17. Noise models and cryo-EM drift correction with a direct-electron camera

    PubMed Central

    Shigematsu, H.; Sigworth, F. J.

    2013-01-01

    Blurring due to specimen-holder drift is a common occurrence in cryo-EM images. Cameras employing active-pixel sensors are capable of high frame rates such that a single low-dose exposure can be acquired as a series of frames. In this paper we consider the possibility of tracking and compensating for overall drift in typical single-particle specimens through the analysis of frame sequences. A problem that arises in tracking through cross-correlation of frames obtained with the DE-12 camera from Direct Electron LLC is the presence of “hot-pixel noise”. This random pattern of bright pixels is highly correlated among frames. We show how a model of this noise can be employed to greatly reduce its effects. A filter function is derived that optimizes the tracking of image shifts by cross-correlation, and we demonstrate the tracking of specimen drift in typical cryo-EM specimens. PMID:23748163

  18. The mean field theory in EM procedures for blind Markov random field image restoration.

    PubMed

    Zhang, J

    1993-01-01

    A Markov random field (MRF) model-based EM (expectation-maximization) procedure for simultaneously estimating the degradation model and restoring the image is described. The MRF is a coupled one which provides continuity (inside regions of smooth gray tones) and discontinuity (at region boundaries) constraints for the restoration problem which is, in general, ill posed. The computational difficulty associated with the EM procedure for MRFs is resolved by using the mean field theory from statistical mechanics. An orthonormal blur decomposition is used to reduce the chances of undesirable locally optimal estimates. Experimental results on synthetic and real-world images show that this approach provides good blur estimates and restored images. The restored images are comparable to those obtained by a Wiener filter in mean-square error, but are most visually pleasing. PMID:18296192

  19. Denoising and covariance estimation of single particle cryo-EM images.

    PubMed

    Bhamre, Tejal; Zhang, Teng; Singer, Amit

    2016-07-01

    The problem of image restoration in cryo-EM entails correcting for the effects of the Contrast Transfer Function (CTF) and noise. Popular methods for image restoration include 'phase flipping', which corrects only for the Fourier phases but not amplitudes, and Wiener filtering, which requires the spectral signal to noise ratio. We propose a new image restoration method which we call 'Covariance Wiener Filtering' (CWF). In CWF, the covariance matrix of the projection images is used within the classical Wiener filtering framework for solving the image restoration deconvolution problem. Our estimation procedure for the covariance matrix is new and successfully corrects for the CTF. We demonstrate the efficacy of CWF by applying it to restore both simulated and experimental cryo-EM images. Results with experimental datasets demonstrate that CWF provides a good way to evaluate the particle images and to see what the dataset contains even without 2D classification and averaging. PMID:27129418

  20. Speech Articulator and User Gesture Measurements Using Micropower, Interferometric EM-Sensore

    SciTech Connect

    Holzrichter, J.F.

    2000-09-15

    Very low power, GHz frequency, ''radar-like'' sensors can measure a variety of motions produced by a human user of machine interface devices. These data can be obtained ''at a distance'' and can measure ''hidden'' structures. Measurements range from acoustic induced 10-micron amplitude vibrations of vocal tract tissues, to few centimeter human speech articulator motions, to meter-class motions of the head, hands, or entire body. These EM sensors measure ''fringe motions' as reflected EM waves are mixed with a local (homodyne) reference wave. These data, when processed using models of the system being measured, provide real time states of interface positions vs. time. An example is speech articulator positions vs. time in the user's body. This information appears to be useful for a surprisingly wide range of applications ranging from speech coding and recognition, speaker or object identification, noise cancellation, hand or head motions for cursor direction, and other applications.

  1. FLOYDS Classification of ASASSN-14em as a SN Ia Around Max

    NASA Astrophysics Data System (ADS)

    Arcavi, I.; Valenti, S.; Howell, D. A.; Hosseinzadeh, G.

    2014-07-01

    We obtained a spectrum of ASASSN-14em (ATel #6342) on 2014 July 26.3 (UT) with the robotic FLOYDS spectrograph mounted on the Faulkes Telescope North. Using Superfit (Howell et al. 2005, ApJ, 634, 1190) and SNID (Blondin & Tonry 2007, ApJ, 666, 1024), we find good matches to spectra of Type Ia supernovae near maximum light at the redshift of the host galaxy (z=0.03).

  2. EMS helicopter incidents reported to the NASA Aviation Safety Reporting System

    NASA Technical Reports Server (NTRS)

    Connell, Linda J.; Reynard, William D.

    1993-01-01

    The objectives of this evaluation were to: Identify the types of safety-related incidents reported to the Aviation Safety Reporting System (ASRS) in Emergency Medical Service (EMS) helicopter operations; Describe the operational conditions surrounding these incidents, such as weather, airspace, flight phase, time of day; and Assess the contribution to these incidents of selected human factors considerations, such as communication, distraction, time pressure, workload, and flight/duty impact.

  3. System concept definition of the Grumman superconducting Electromagnetic Suspension (EMS) Maglev design

    NASA Technical Reports Server (NTRS)

    Proise, M.

    1994-01-01

    Grumman, under contract to the Army Corps of Engineers, completed a System Concept Definition (SCD) study to design a high-speed 134 m/s (300 m.p.h.) magnetically levitated (Maglev) transportation system. The primary development goals were to design a Maglev that is safe, reliable, environmentally acceptable, and low-cost. The cost issue was a predominant one, since previous studies have shown that an economically viable Maglev system (one that is attractive to investors for future models of passenger and/or freight transportation) requires a cost that is about $12.4 M/km ($20 Million per mile). The design is based on the electromagnetic suspension (EMS) system using superconducting iron-core magnets mounted along both sides of the vehicle. The EMS system has several advantages compared to the electrodynamic suspension (EDS) Maglev systems such as low stray magnetic fields in the passenger cabin and the surrounding areas, uniform load distribution along the full length of the vehicle, and small pole pitch for smoother propulsion and ride comfort. It is also levitated at all speeds and incorporates a wrap-around design of safer operation. The Grumman design has all the advantages of an EMS system identified above, while eliminating (or significantly improving) drawbacks associated with normal magnet powered EMS systems. Improvements include larger gap clearance, lighter weight, lower number of control servos, and higher off line switching speeds. The design also incorporates vehicle tilt (plus or minus 9 deg) for higher coordinated turn and turn out speed capability.

  4. Software features of a DBMS kernel in large real-time EMS systems

    SciTech Connect

    Schwab, B.C.; Hemmaplardh, K.; Sackett, S.A.; Lawrence, G.M.; Davis, R.N.; Daine, D.N.

    1988-02-01

    A number of performance improvement features were designed and implemented in a database management system (DBMS). The performance oriented DBMS is of the relational model. The DBMS was specifically developed for real-time energy management and control systems (EMS) for electric utilities. Previous analysis had shown that commercially available DBMSs could not meet the performance requirements for the application. This paper describes the performance improvement software features.

  5. Quantum theory of extended particle dynamics in the presence of EM radiation-reaction

    NASA Astrophysics Data System (ADS)

    Cremaschini, Claudio; Tessarotto, Massimo

    2015-08-01

    In this paper a trajectory-based relativistic quantum wave equation is established for extended charged spinless particles subject to the action of the electromagnetic (EM) radiation-reaction (RR) interaction. The quantization pertains the particle dynamics, in which both the external and self EM fields are treated classically. The new equation proposed here is referred to as the RR quantum wave equation. This is shown to be an evolution equation for a complex scalar quantum wave function and to be realized by a first-order PDE with respect to a quantum proper time s . The latter is uniquely prescribed by representing the RR quantum wave equation in terms of the corresponding quantum hydrodynamic equations and introducing a parametrization in terms of Lagrangian paths associated with the quantum fluid velocity. Besides the explicit proper time dependence, the theory developed here exhibits a number of additional notable features. First, the wave equation is variational and is consistent with the principle of manifest covariance. Second, it permits the definition of a strictly positive 4-scalar quantum probability density on the Minkowski space-time, in terms of which a flow-invariant probability measure is established. Third, the wave equation is non-local, due to the characteristic EM RR retarded interaction. Fourth, the RR wave equation recovers the Schrödinger equation in the non-relativistic limit and the customary Klein-Gordon wave equation when the EM RR is negligible or null. Finally, the consistency with the classical RR Hamilton-Jacobi equation is established in the semi-classical limit.

  6. From SubPAR to PAR, into the CryoEM, and More Macrolides.

    PubMed

    2016-06-23

    Every month the editors of Cell Chemical Biology bring you highlights of the most recent chemical biology literature. Our June 2016 selection includes new efforts to map ADP-ribosylation sites and get a deeper view of their functional relevance, an illustration of why cryoEM should now be considered an important player in facilitating structure-based drug development and design, and a new way to synthesize a wide range of macrolide antibiotics. PMID:27341428

  7. Expert verification of the knowledge base of FEED--a feedback expert system for EMS documentation.

    PubMed

    Saini, Devashish; Orthner, Helmuth F; Berner, Eta S; Mirza, Muzna; Godwin, Charles J; Brown, Todd B

    2008-01-01

    Feedback Expert System for Emergency Medical Services (EMS) Documentation (FEED) has a rule-based knowledge base (KB) that was verified against specifications in a focus group consisting of six experts. The focus group suggested changes in almost all rules discussed, indicating that the KB did not meet specifications at that stage of development. However, enough information was gathered to address these issues in the next iteration of development. PMID:18999259

  8. The microtubule binding drug EM011 inhibits the growth of paediatric low grade gliomas.

    PubMed

    Ajeawung, Norbert F; Joshi, Harish C; Kamnasaran, Deepak

    2013-07-10

    Low grade gliomas are a heterogeneous group of tumours representing the most common form of neoplasms in the central nervous system among children. Although gross total resection remains the principal treatment, it is often impractical especially for the resection of tumours within eloquent regions of the brain. Instead Radiotherapy is utilised in such cases, but because of its associated toxicities, it is refrained from use among younger children. These limitations coupled with hypersensitivity and toxicities associated with some commonly used chemotherapeutic agents, have ignited the need to search for safer and more effective treatments for paediatric low grade gliomas. In this study, we investigated the EM011 drug on the growth of two pilocytic and one diffuse paediatric astrocytoma cell lines, using an assortment of cancer assays. We discovered that treatments of low grade gliomas with EM011 abrogated cell viability by inducing a decrease in cell proliferation and an arrest in the S and G2M cell cycle phases, followed by a converse increase in apoptosis in a dose and time dependent manner. The cell migratory and invasion indices, as well as anchorage independent growth in soft agarose, were significantly attenuated. These findings were mechanistically associated with a transient release of AIF, a disruption of microtubule architecture, and a decline in the expression of key genes which drive cancer progression including EGFR, mTORC1, JUN and multiple MMPs. In fact, the activity of MMP2 was also perturbed by EM011. These findings, in conjunction with the insignificant adverse side effects established from other studies, make EM011 an appealing chemotherapeutic agent for the treatment of paediatric low grade gliomas. PMID:23402815

  9. Implementation of the EM Algorithm in the Estimation of Item Parameters: The BILOG Computer Program.

    ERIC Educational Resources Information Center

    Mislevy, Robert J.; Bock, R. Darrell

    This paper reviews the basic elements of the EM approach to estimating item parameters and illustrates its use with one simulated and one real data set. In order to illustrate the use of the BILOG computer program, runs for 1-, 2-, and 3-parameter models are presented for the two sets of data. First is a set of responses from 1,000 persons to five…

  10. Using Cryo-EM to Map Small Ligands on Dynamic Metabolic Enzymes: Studies with Glutamate Dehydrogenase

    PubMed Central

    Borgnia, Mario J.; Banerjee, Soojay; Merk, Alan; Matthies, Doreen; Bartesaghi, Alberto; Rao, Prashant; Pierson, Jason; Earl, Lesley A.; Falconieri, Veronica

    2016-01-01

    Cryo-electron microscopy (cryo-EM) methods are now being used to determine structures at near-atomic resolution and have great promise in molecular pharmacology, especially in the context of mapping the binding of small-molecule ligands to protein complexes that display conformational flexibility. We illustrate this here using glutamate dehydrogenase (GDH), a 336-kDa metabolic enzyme that catalyzes the oxidative deamination of glutamate. Dysregulation of GDH leads to a variety of metabolic and neurologic disorders. Here, we report near-atomic resolution cryo-EM structures, at resolutions ranging from 3.2 Å to 3.6 Å for GDH complexes, including complexes for which crystal structures are not available. We show that the binding of the coenzyme NADH alone or in concert with GTP results in a binary mixture in which the enzyme is in either an “open” or “closed” state. Whereas the structure of NADH in the active site is similar between the open and closed states, it is unexpectedly different at the regulatory site. Our studies thus demonstrate that even in instances when there is considerable structural information available from X-ray crystallography, cryo-EM methods can provide useful complementary insights into regulatory mechanisms for dynamic protein complexes. PMID:27036132

  11. Discos de acresção em sistemas Be-X

    NASA Astrophysics Data System (ADS)

    Lopes de Oliveira, R.; Janot-Pacheco, E.

    2003-08-01

    Alguns fenômenos de outbursts em Be-X sugerem a existência, mesmo que temporária, de um disco de acresção quando da passagem do objeto compacto pelo periastro orbital. Neste trabalho avaliamos a possibilidade de formação do disco de acresção em sistemas Be+estrela de neutrons e Be+anã branca, e a influência da excentricidade orbital na ocorrência deste fenômeno. Utilizamos a expressão analítica para o momento angular específico da matéria constituinte de um meio em expansão lenta, como é o caso do disco circunstelar das estrelas Be, proposta por Wang(1981), sob a condição básica de que o raio de circularização deva ser maior do que o raio de Alfvén. Concluímos que existe um limite para o período orbital do sistema acima do qual não é possível a formação do disco de acresção, e que este valor aumenta para sistemas com excentricidade orbital maior.

  12. A Graph Theory Method For Determination Of Cryo-EM Image Focuses

    PubMed Central

    Jiang, Wen; Guo, Fei; Liu, Zheng

    2012-01-01

    Accurate determination of micrograph focuses is essential for averaging multiple images to reach high-resolution 3-D reconstructions in electron cryo-microscopy (cryo-EM). Current methods use iterative fitting of focus-dependent simulated power spectra to the power spectra of experimental images, with the fitting performed independently for different images. Here we have developed a novel graph theory based method in which the rotational average focus and individual angular sector focuses of all images are determined simultaneously in closed form using the least square solution of overdetermined linear equations. The new method was shown to be fast, accurate, and robust in tests with large datasets of experimental low dose cryo-EM images. Its integration with three classic power spectra fitting methods also allows cross validation of the results by these vastly different methods. The new integrated focus determination method will improve reliability of automated focus determination for large-scale data processing that is increasingly common in the cryo-EM field. PMID:22842112

  13. Helicopter-borne measurements of sea ice thickness, using a small and lightweight, digital EM system

    NASA Astrophysics Data System (ADS)

    Haas, Christian; Lobach, John; Hendricks, Stefan; Rabenstein, Lasse; Pfaffling, Andreas

    2009-03-01

    Sea ice is an important climate variable and is also an obstacle for marine operations in polar regions. We have developed a small and lightweight, digitally operated frequency-domain electromagnetic-induction (EM) system, a so-called EM bird, dedicated for measurements of sea ice thickness. It is 3.5 m long and weighs only 105 kg, and can therefore easily be shipped to remote places and operated from icebreakers and small helicopters. Here, we describe the technical design of the bird operating at two frequencies of f1 = 3.68 kHz and f2 = 112 kHz, and study its technical performance. On average, noise amounts to ± 8.5 ppm and ± 17.5 ppm for f1 and f2, respectively. Electrical drift amounts to 200 ppm/h and 2000 ppm/h for f1 and f2, during the first 0.5 h of operation. It is reduced by 75% after 2 h. Calibration of the Inphase and Quadrature ppm signals varies by 2 to 3%. A sensitivity study shows that all these signal variations do affect the accuracy of the ice thickness retrieval, but that it remains better than ± 0.1 m over level ice in most cases. This accuracy is also confirmed by means of comparisons of the helicopter EM data with other thickness measurements. The paper also presents the ice thickness retrieval from single-component Inphase data of f1.

  14. Application of Fuzzy Logic to EMS-type Magnetically Levitated Railway Vehicle

    NASA Astrophysics Data System (ADS)

    Kusagawa, Shinichi; Baba, Jumpei; Shutoh, Katsuhiko; Masada, Eisuke

    A type of the magnetically levitated railway system with the electro-magnetic suspension system (EMS), which is named HSST system, will be put into revenue service as an urban transport in Nagoya, Japan at the beginning of April 2005. To extend its operational velocity higher than 200km/h for applications in other cities, the design of its EMS system is reexamined for improvement of riding comfort and performances of a train. In order to achieve these objectives, the multipurpose optimization on the basis of the genetic algorithm is applied for the design of EMS-type magnetically levitated vehicle, control parameters of which are optimized both to follow the rail exactly in high-speed and to provide enough riding comfort to passengers. However, the ability to follow sharp irregularities of the rail and to cope with high frequency noises in the gap length control system should be coordinated with riding comfort. The fuzzy logic is introduced into the dynamic control loop and verified to solve the problem. Far better coordination is obtained between the vehicle performances and riding comfort of passengers in high-speed against such various rail conditions. The levitation control with fuzzy logic is shown to be useful for the critical design problem as the high-speed maglev railways.

  15. 2000 200-city survey. Operational & clinical EMS trends in large, urban areas.

    PubMed

    Cady, G; Lindberg, D

    2001-02-01

    The year's survey illustrated ongoing stability with respect to providers and operational approaches, and explored relationships that could provide opportunities for improvement. The continued use of hot response to every request for service is a high-risk response strategy. Today's EMD protocol systems can enable systems to safely prioritize requests for service. Response time performance reported by measure interval and averaged response time, while appearing to follow a rational model for transportation providers, fell short with respect to first responder response times which appeared to have no correlation with response clock start times. A possible explanation for this difference is the lower percentage of first responder agencies that are subject to external response-time performance review. The medical direction results suggest an investment in a full-time medical director could reduce online medical control requirements. The use of handheld computing technology could serve as a vehicle for building accurate clinical databases, as well as a means to deliver DS technology to the patient's bedside. Use of this technology could also improve reimburesment through more accurate reporting. The future of EMS has enormous challenges that must be overcome, especially in light of reduced health-care insurance reimbursements. However, these challenges also present an opportunity for EMS to reinvent itself. The capture and analysis of operational and clinical data by EMS systems will prove essential to understanding what changes can be made to enable them to meet future demands. PMID:11227116

  16. Cryo-EM: A Unique Tool for the Visualization of Macromolecular Complexity

    PubMed Central

    Nogales, Eva; Scheres, Sjors H.W.

    2015-01-01

    Three-dimensional cryo-electron microscopy (cryo-EM) is an expanding structural biology technique that has recently undergone a quantum leap progression in its achievable resolution and its applicability to the study of challenging biological systems. Because crystallization is not required, only small amounts of sample are needed, and, because images can be classified in a computer, the technique has the potential to deal with compositional and conformational mixtures. Therefore, cryo-EM can be used to investigate complete and fully functional macromolecular complexes in different functional states, providing a richness of biological insight. In this review we underlie some of the principles behind the cryo-EM methodology of single particle analysis and discuss some recent results of its application to challenging systems of paramount biological importance. We place special emphasis on new methodological developments that are leading to an explosion of new studies, many of which are reaching resolutions that could only be dreamed of only a couple of years ago. PMID:26000851

  17. Standard error estimation using the EM algorithm for the joint modeling of survival and longitudinal data

    PubMed Central

    Xu, Cong; Baines, Paul D.; Wang, Jane-Ling

    2014-01-01

    Joint modeling of survival and longitudinal data has been studied extensively in the recent literature. The likelihood approach is one of the most popular estimation methods employed within the joint modeling framework. Typically, the parameters are estimated using maximum likelihood, with computation performed by the expectation maximization (EM) algorithm. However, one drawback of this approach is that standard error (SE) estimates are not automatically produced when using the EM algorithm. Many different procedures have been proposed to obtain the asymptotic covariance matrix for the parameters when the number of parameters is typically small. In the joint modeling context, however, there may be an infinite-dimensional parameter, the baseline hazard function, which greatly complicates the problem, so that the existing methods cannot be readily applied. The profile likelihood and the bootstrap methods overcome the difficulty to some extent; however, they can be computationally intensive. In this paper, we propose two new methods for SE estimation using the EM algorithm that allow for more efficient computation of the SE of a subset of parametric components in a semiparametric or high-dimensional parametric model. The precision and computation time are evaluated through a thorough simulation study. We conclude with an application of our SE estimation method to analyze an HIV clinical trial dataset. PMID:24771699

  18. Stability analysis, modeling, simulation and experimental testing of an EMS Maglev system with structural flexibility

    NASA Astrophysics Data System (ADS)

    Hanasoge, Aravind M.

    Vehicle-guideway interaction studies of Magnetically Levitated (Maglev) vehicles indicate that structural flexibility can adversely affect the overall stability and performance of such systems. This is one of the reasons why guideways are generally made very rigid. This in turn leads to increased cost of the overall system since guideway construction forms a significant portion of the overall cost. In this dissertation, the influence of structural flexibility on the stability of Electromagnetic Suspension (EMS) Maglev systems is studied. It is shown how inherently unstable and flexible structure EMS Maglev systems can achieve guaranteed stability by using collocated actuators and sensors, along with de-centralized Proportional plus Derivative (PD) controllers. These results are valid even in the presence of Track/Guideway flexibility. A detailed dynamic model is developed for the EMS Maglev demonstration system (Test Bogie) currently under research and development at Old Dominion University (ODU). This model incorporates structural dynamics with flexible modes of vibration, non-linear electrodynamics, feedback controllers, discrete time implementation, noise filters and disturbance inputs. This model is validated via real time experimental testing. The model thus validated is used for simulation case studies involving levitation and lateral disturbance, lateral control, and centralized control.

  19. Hadron calorimeter performance with a PbWO4 EM compartment

    SciTech Connect

    Green, D.

    1996-01-01

    The CMS detector[1] at the LHC has chosen PbWO4 in order to achieve the superior photon energy resolution which is crucial in searching for the 2 photon decay of low mass Higgs bosons. The hadronic compartment is thought to be Cu absorber, since one is immersed in a 4 T magnetic field, read out by scintillator tiles coupled to wavelength shifter (WLS) fibers. The combined performance of this calorimeter is of interest in the study of jets and missing transverse energy (neutrino, SUSY signatures). For this reason, a test was made of the electromagnetic (EM) compartment combined with a reasonable approximation to the baseline HCAL ``barrel`` calorimeter. Data was taken in the H4 CERN beamline. The EM compartment was a 7 {times} 7 square array of PbWO4 crystals, which for the purposes of this study are considered as a single readout in depth (or ``compartment``) [2]. The HCAL module consisted of large scintillator plates with 24 individual longitudinal readout channels. The EM compartment was followed by 10 Cu plates each 3 cm thick, followed by 9 Cu plates each 6 cm thick. This set of absorber plates represented the HCAL compartments inside the coil. The coil itself [1] was approximated as Al and Fe plates, of a total thickness of about 1.4 absorption lengths. The coil mockup was sampled and then followed by 4 plates of 8 cm thick Cu, each with an individual readout which represented a test of the ``Tailcatcher`` concept.

  20. Standard error estimation using the EM algorithm for the joint modeling of survival and longitudinal data.

    PubMed

    Xu, Cong; Baines, Paul D; Wang, Jane-Ling

    2014-10-01

    Joint modeling of survival and longitudinal data has been studied extensively in the recent literature. The likelihood approach is one of the most popular estimation methods employed within the joint modeling framework. Typically, the parameters are estimated using maximum likelihood, with computation performed by the expectation maximization (EM) algorithm. However, one drawback of this approach is that standard error (SE) estimates are not automatically produced when using the EM algorithm. Many different procedures have been proposed to obtain the asymptotic covariance matrix for the parameters when the number of parameters is typically small. In the joint modeling context, however, there may be an infinite-dimensional parameter, the baseline hazard function, which greatly complicates the problem, so that the existing methods cannot be readily applied. The profile likelihood and the bootstrap methods overcome the difficulty to some extent; however, they can be computationally intensive. In this paper, we propose two new methods for SE estimation using the EM algorithm that allow for more efficient computation of the SE of a subset of parametric components in a semiparametric or high-dimensional parametric model. The precision and computation time are evaluated through a thorough simulation study. We conclude with an application of our SE estimation method to analyze an HIV clinical trial dataset. PMID:24771699

  1. Using Cryo-EM to Map Small Ligands on Dynamic Metabolic Enzymes: Studies with Glutamate Dehydrogenase.

    PubMed

    Borgnia, Mario J; Banerjee, Soojay; Merk, Alan; Matthies, Doreen; Bartesaghi, Alberto; Rao, Prashant; Pierson, Jason; Earl, Lesley A; Falconieri, Veronica; Subramaniam, Sriram; Milne, Jacqueline L S

    2016-06-01

    Cryo-electron microscopy (cryo-EM) methods are now being used to determine structures at near-atomic resolution and have great promise in molecular pharmacology, especially in the context of mapping the binding of small-molecule ligands to protein complexes that display conformational flexibility. We illustrate this here using glutamate dehydrogenase (GDH), a 336-kDa metabolic enzyme that catalyzes the oxidative deamination of glutamate. Dysregulation of GDH leads to a variety of metabolic and neurologic disorders. Here, we report near-atomic resolution cryo-EM structures, at resolutions ranging from 3.2 Å to 3.6 Å for GDH complexes, including complexes for which crystal structures are not available. We show that the binding of the coenzyme NADH alone or in concert with GTP results in a binary mixture in which the enzyme is in either an "open" or "closed" state. Whereas the structure of NADH in the active site is similar between the open and closed states, it is unexpectedly different at the regulatory site. Our studies thus demonstrate that even in instances when there is considerable structural information available from X-ray crystallography, cryo-EM methods can provide useful complementary insights into regulatory mechanisms for dynamic protein complexes. PMID:27036132

  2. Almost lost in translation. Cryo-EM of a dynamic macromolecular complex: the ribosome.

    PubMed

    Valle, Mikel

    2011-05-01

    Ribosomes are dynamic biological machines that perform numerous tasks during translation, the biosynthesis of proteins. Translocation, the movement of transfer RNAs (tRNAs) and messenger RNA (mRNA) to progress in the reading frame of codons in the mRNA, takes place after the addition of each amino acid. This process involves large ribosome conformational changes, where tRNAs proceed through intermediate states. The structural characterization of these translocation intermediates has remained elusive. Cryo-electron microscopy (cryo-EM) produces three-dimensional averages, and translocating ribosomes poise distinct conformational states, and hence, structurally heterogeneous populations. During the last decade, the quest for visualization of translocation intermediates has progressed together with the development of classification tools in cryo-EM. Some of these new tools have recently been tested in ribosomal translocation, uncovering a clearer picture of the process. This success goes along with the latest advances in cryo-EM and illustrates how the technique offers multiple possibilities for studying macromolecular complexes engaged in dynamic reactions. PMID:21336521

  3. Crosshole EM for oil field characterization and EOR monitoring: Field examples

    SciTech Connect

    Wilt, M.; Schenkel, C.; Torres-Verdin, C.; Lee, Ki Ha; Tseng, Hung-Wen

    1994-09-01

    Crosshole and surface-to-borehole electromagnetic (EM) imaging is applied to reservoir characterization and steam flood monitoring in a central California oil field. Steam was injected into three stacked, eastward-dipping, unconsolidated oil sands within the upper 200 in. The steam plume is expected to develop as an ellipse aligned with the regional northwest-southeast strike. EM measurements were made from two flberglass-cased observation wells straddling the steam injector on a northeast-southwest profile. Field data were collected before the initiation of a steam drive to map the distribution of the oil sands and then six months after the steam was injected to monitor the progress of the steam chest. Resisitivity images derived from the EM data collected before steam injection clearly delineate the distribution and dipping structure on the target oil sands. Difference images from data collected before and after steam flooding indicate that the steam chest has developed only in the deeper oil sands, and it has preferentially migrated eastward. Surface-to-borehole measurements were useful in mapping the distribution of the major oil sands, but they were insensitive to resisitivity changes in the early stages of the steam flood.

  4. Particle migration analysis in iterative classification of cryo-EM single-particle data

    PubMed Central

    Chen, Bo; Shen, Bingxin; Frank, Joachim

    2014-01-01

    Recently developed classification methods have enabled resolving multiple biological structures from cryo-EM data collected on heterogeneous biological samples. However, there remains the problem of how to base the decisions in the classification on the statistics of the cryo-EM data, to reduce the subjectivity in the process. Here, we propose a quantitative analysis to determine the iteration of convergence and the number of distinguishable classes, based on the statistics of the single particles in an iterative classification scheme. We start the classification with more number of classes than anticipated based on prior knowledge, and then combine the classes that yield similar reconstructions. The classes yielding similar reconstructions can be identified from the migrating particles (jumpers) during consecutive iterations after the iteration of convergence. We therefore termed the method “jumper analysis”, and applied it to the output of RELION 3D classification of a benchmark experimental dataset. This work is a step forward toward fully automated single-particle reconstruction and classification of cryo-EM data. PMID:25449317

  5. Direct electron detection yields cryo-EM reconstructions at resolutions beyond ¾ Nyquist frequency

    PubMed Central

    Bammes, Benjamin E.; Rochat, Ryan H.; Jakana, Joanita; Chen, Dong-Hua; Chiu, Wah

    2012-01-01

    One limitation in electron cryo-microscopy (cryo-EM) is the inability to recover high-resolution signal from the image-recording media at the full-resolution limit of the transmission electron microscope. Direct electron detection using CMOS-based sensors for digitally recording images has the potential to alleviate this shortcoming. Here, we report a practical performance evaluation of a Direct Detection Device (DDD) for biological cryo-EM at two different microscope voltages: 200 and 300 kV. Our DDD images of amorphous and graphitized carbon show strong per-pixel contrast with image resolution near the theoretical sampling limit of the data. Single-particle reconstructions of two frozen-hydrated bacteriophages, P22 and ε15, establish that the DDD is capable of recording usable signal for 3-D reconstructions at about 4/5 of the Nyquist frequency, which is a vast improvement over the performance of conventional imaging media. We anticipate the unparalleled performance of this digital recording device will dramatically benefit cryo-EM for routine tomographic and single-particle structural determination of biological specimens. PMID:22285189

  6. The decision to add a second hospital-based EMS helicopter.

    PubMed

    Friedman, R; Leicht, M J; Brotman, S

    1989-11-01

    An analysis of the first seven years of performance of our hospital-based emergency medical services (EMS) helicopter was conducted to evaluate the possible need for a second aircraft. A survey of seven hospitals currently operating two or more helicopters resulted in a consensus that one helicopter can effectively perform only 70 to 90 flights per month. The number of requests for our helicopter service has increased 148% from 610 to 1,512 in seven years while the number of completed missions has increased only 92% from 486 (40.5/month) to 935 (78/month). Requests denied due to inclement weather (265 in 1988) cannot be captured with a second visual-flight-rated (VFR) EMS helicopter; however, those missed due to maintenance requirements of the helicopter and overlapping requests (232 in 1988) can be captured. The need for a second aircraft exists when the number of requests for the service grows while the number of captured flights plateaus. Our data and industry survey suggests this will occur at 75 captured flights per month. Affordability and continued overall growth of trauma and other critical care referrals to the base hospital(s) is mandatory. This study provides a model for hospital-based EMS helicopter operators to apply to the decision whether to add a second aircraft. PMID:10296622

  7. Uma grade de perfis teóricos para estrelas massivas em transição

    NASA Astrophysics Data System (ADS)

    Nascimento, C. M. P.; Machado, M. A.

    2003-08-01

    Na XXVIII Reunião Anual da Sociedade Astronômica Brasileira (2002) apresentamos uma grade de perfis calculados de acordo com os pontos da trajetória evolutiva de metalicidade solar, Z = 0.02 e taxa de perda de massa () padrão, para estrelas com massa inicial de 25, 40, 60, 85 e 120 massas solares. Estes perfis foram calculados com o auxílio de um código numérico adequado para descrever os ventos de objetos massivos, supondo simetria esférica, estacionaridade e homogeneidade. No presente trabalho, apresentamos a complementação da grade com os perfis teóricos relativos às trajetórias de Z = 0.02 com taxa de perda de massa dobrada em relação a padrão (2´), e de metalicidade Z = 0.008. Para cada ponto das três trajetórias obtemos os perfis teóricos de Ha, Hb, Hg e Hd, e como esperado eles se apresentam em pura emissão, pura absorção ou em P-Cygni. Para valores de taxa de perda de massa muito baixos (~10-7) não há formação de linhas, o que é visto nos primeiros pontos em todas as trajetórias. Em geral, para um mesmo ponto a componente de emissão diminui e a absorção aumenta de Ha para Hd. É verificado que as trajetórias com Z = 0.02 e padrão possuem menos circuitos (loops) do que as com metalicidade Z = 0.02 e 2´ padrão, e seus perfis são, em geral, menos intensos. Em relação a trajetória de Z = 0.008, verifica-se menos circuitos e maior variação em luminosidade, e seus perfis mostram-se em, algumas trajetórias, mais intensos. Verificamos também que, pontos distintos em uma mesma trajetória, apresentam perfis diferentes para valores similares de luminosidade e temperatura efetiva. Sendo assim, uma grade de perfis teóricos parece ser útil para fornecer uma informação preliminar sobre o estágio evolutivo de uma estrela massiva.

  8. PREVALÊNCIA DE ENDOSSIMBIONTES Cardinium EM POPULAÇÕES DE ÁCAROS Brevipalpus phoenicis DE DIFERENTES REGIÕES BRASILEIRAS.

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Em B. phoenicis (Geijskes) (Acari: Tenuipalpidae), ácaro vetor de importantes fitovírus, a presença de endossimbiontes do gênero Cardinium relaciona-se ao processo de feminilização dos machos, acarretando em elevada proporção de fêmeas em populações naturais. Até o momento, não é conhecido se este e...

  9. Using EMS Dispatch to Trigger STEMI Alerts Decreases Door-to-Balloon Times

    PubMed Central

    Stowens, Justin C.; Sonnad, Seema S.; Rosenbaum, Robert A.

    2015-01-01

    Introduction We sought to determine the potential reduction in door-to-balloon time (DTB) by allowing paramedics to perform prehospital ST-Elevation Myocardial Infarction (STEMI) notification using brief communications via emergency medical services (EMS) 9-1-1 dispatchers as soon as they saw a STEMI on 12-lead electrocardiogram (EKG). Our hypothesis was that earlier cardiac catheterization lab (CCL) activation would improve overall DTB and avoid delays arising from on-scene issues or the time required to deliver a full report. Methods The study setting was a single suburban community teaching hospital, which is a regional percutaneous coronary intervention (PCI) center with more than 120,000 Emergency Department (ED) visits/year and is serviced by a single tiered-response, advanced life support (ALS) paramedic-level agency. STEMI notifications from July 2009 to July 2012 occurred by either standard direct EMS-to-physician notification or by immediate 9-1-1 dispatch notification. In the 9-1-1 dispatcher-aided notification method, paramedics were asked to provide a brief one-sentence report using their lapel microphones upon immediate realization of a diagnostic EKG (usually within 1–2 minutes of patient contact). This report to the 9-1-1 dispatcher included the patient’s sex, age, and cardiologist (if known). The dispatcher then called the emergency department attending and informed them that a STEMI was being transported and that CCL activation was needed. We used retrospective chart review of a consecutive sample of patients from an existing STEMI registry to determine whether there was a statistically significant difference in DTB between the groups. Results Eight hundred fifty-six total STEMI alert patients arrived by EMS during the study. We excluded 730 notifications due to events such as cardiac arrest, arrhythmia, death, resolution of EKG changes and/or symptoms, cardiologist decision not to perform PCI, arrival as a transfer after prior stabilization

  10. Theory and detection scheme of seismic EM signals transferred into the atmosphere from the oceanic and continental lithosphere

    NASA Astrophysics Data System (ADS)

    Novik, Oleg; Ershov, Sergey; Ruzhin, Yuri; Smirnov, Fedor; Volgin, Maxim

    2014-07-01

    Due to the compound structure of the medium and large portions of energy transferred, a seismic excitation in the oceanic or continental lithosphere disturbs all types of geophysical fields. To investigate the problem of electromagnetic (EM) disturbances in the atmosphere from the seismically activated lithosphere, we have formulated two mathematical models of interaction of fields of different physical nature resulting in arising of the low-frequency (from 0.1 to 10 Hz by amplitude of a few hundreds of pT) EM signals in the atmosphere. First we have considered the EM field generation in the moving oceanic lithosphere and then in the moving continental one. For both cases, the main physical principles and geological data were applied for formulation of the model and characteristics of the computed signals of different nature agree with measurements of other authors. On the basis of the 2D model of the seismo-hydro-EM-temperature interaction in the lithosphere-Ocean-atmosphere domain, a block-scheme of a multisensory vertically distributed (from a seafloor up to the ionosphere) tsunami precursors' detection system is described. On the basis of the 3D model of the seismo-EM interaction in a lithosphere-atmosphere domain, we explain why Prof. Kopytenko (Inst. IZMIRAN of Russian Acad. Sci.) and co-authors were able to estimate location of the future seismic epicenter area from their magnetic field measurements in the atmosphere near the earth's surface.

  11. Observações no infravermelho médio de objetos estelares jovens em NGC 3576

    NASA Astrophysics Data System (ADS)

    Barbosa, C.; Damineli, A.; Blum, R.; Conti, P.

    2003-08-01

    Apresentamos os resultados de observações no infravermelho médio de candidatos a objetos estelares jovens e massivos em NGC 3576. As imagens de alta resolução foram obtidas no observatório Gemini Sul com o uso dos filtros em 10,8, 7,9, 9,8, 12,5 e 18,2 mm. Nossas imagens mostram a fonte IRS 1 resolvida em 4 objetos pela primeira vez em 10 mm. Para cada objeto obtivemos a distribuição espectral de energia de 1.2 até 18 mm, bem como a temperatura de cor, a distribuição espacial e a profundidade óptica em 9,8 mm da poeira circunstelar. Apresentamos uma estimativa das massas dos objetos estudados, baseados na luminosidade emitida no infravermelho médio, bem como um modelo para explicar as diferentes características observadas de cada objeto. Finalmente discutimos a possível localização da(s) fonte(s) de ionização de NGC 3576.

  12. Deciphering the Use and Predictive Value of “EMS Provider Judgment” in Out-of-Hospital Trauma Triage: A Multi-site, Mixed Methods Assessment

    PubMed Central

    Newgard, Craig D.; Kampp, Michael; Nelson, Maria; Holmes, James F.; Zive, Dana; Rea, Thomas; Bulger, Eileen M.; Liao, Michael; Sherck, John; Hsia, Renee Y.; Wang, N. Ewen; Fleischman, Ross J.; Barton, Erik D.; Daya, Mohamud; Heineman, John; Kuppermann, Nathan

    2012-01-01

    Background “EMS provider judgment” was recently added as a field triage criterion to the national guidelines, yet its predictive value and real-world application remain unclear. We examine the use and independent predictive value of EMS provider judgment in identifying seriously injured persons. Methods We analyzed a population-based retrospective cohort, supplemented by qualitative analysis, of injured children and adults evaluated and transported by 47 EMS agencies to 94 hospitals in 5 regions across the Western U.S. from 2006–2008. We used logistic regression models to evaluate the independent predictive value of EMS provider judgment for ISS ≥ 16. EMS narratives were analyzed using qualitative methods to assess and compare common themes for each step in the triage algorithm, plus EMS provider judgment. Results 213,869 injured patients were evaluated and transported by EMS over the 3-year period, of whom 41,191 (19.3%) met at least one of the field triage criteria. EMS provider judgment was the most commonly used triage criterion (40.0% of all triage-positive patients; sole criterion in 21.4%). After accounting for other triage criteria and confounders, the adjusted odds ratio (OR) of ISS ≥ 16 for EMS provider judgment was 1.23 (95%CI 1.03-1.47), although there was variability in predictive value across sites. Patients meeting EMS provider judgment had concerning clinical presentations qualitatively similar to those meeting mechanistic and other special considerations criteria. Conclusions Among this multi-site cohort of trauma patients, EMS provider judgment was the most commonly used field trauma triage criterion, was independently associated with serious injury and was useful in identifying high risk patients missed by other criteria. However, there was variability in predictive value between sites. PMID:22673250

  13. População nuclear e extranuclear em rádio-galáxias

    NASA Astrophysics Data System (ADS)

    Raimann, D. I.; Storchi-Bergmann, T.; Quintana, H.; Alloin, D.; Hunstead, R.; Wisotzki, L.

    2003-08-01

    A natureza do contínuo UV/ótico em rádio-galáxias é muito importante para o seu entendimento. Em baixos redshifts existem evidências de que muitas delas são dominadas no ótico por luz de estrelas velhas, características de galáxias early-type e em altos redshifts a característica dominante é um excesso de luz no UV, freqüentemente associado com estruturas que estão alinhadas aos eixos das estruturas rádio em grande escala. Inicialmente esse excesso foi interpretado como devido a episódios intensos de formação estelar nas galáxias hospedeiras. Entretanto, as descobertas dos alinhamentos entre as estruturas UV e rádio modificaram essa idéia. Foi proposto que a formação estelar é iniciada pela passagem do jato rádio através do meio interestelar das galáxias hospedeiras. A natureza do excesso UV começou a ser compreendida em um estudo detalhado do continuo ótico da 3C321, onde se concluiu que o contínuo desta galáxia tem origem multicomponente, com contribuições de populações velhas e intermediárias, de luz espalhada oriunda de um quasar obscurecido e do contínuo nebular. No presente trabalho estudamos a população nuclear e extranuclear de uma amostra de 24 rádio-galáxias, utilizando espectros óticos de fenda longa, com alta razão sinal/ruído. Através do método de síntese espectral de populações estelares, foram estimadas as contribuições de populações estelares de diferentes idades (e de um contínuo tipo lei de potência devido a um AGN, FC) para a luz integrada das galáxias, em 4020Å. As principais conclusões deste trabalho são: apenas quatro dos objetos estudados têm contribuições significativas (maiores do que 10%) das populações de 100 milhões de anos ou mais jovens (ou de FC) ao longo da região espacial estudada (6 kpc centrais); nenhuma das rádio-galáxias de tipo FRI estudadas tem contribuição significativa destas populações ao longo desta região; duas (de oito) de tipo FRII tem contribui

  14. Tritium contamination at EG&G/EM in North Las Vegas, Nevada

    SciTech Connect

    Sowell, C.V.; Arent, L.J.

    1996-06-01

    The tritium contamination discovered at the EG&G Energy Measurements (EG&G/EM) facility in North Las Vegas, Nevada, on 20 April 1995, could have been averted by good health physics practices and/or adequate management oversight. Scandium tritide (ScT{sub 3}) targets were installed for use in sealed tube neutron generators at EG&G/EM. In addition, EG&G/EM was also storing zirconium tritide (ZrT{sub 3}) and titanium tritide (TiT{sub 3}) foils. Since the targets were classified as sealed sources, the appropriate administrative and engineering control measures such as relocating targets/sources, air monitoring, bioassay, waste stream management, labeling/posting and training were not implemented. In all there were six unreported incidents of tritium contamination from March 1994 to July 1995. Swipe surveys revealed areas exceeding the action level of 10,000 dpm/100 cm{sup 2} by up to three orders of magnitude. After reclassifying the targets as unsealed sources, a bioassay program was instituted, and the results were higher than expected for three employees. The doses assigned to the three individuals working in the contaminated area were 35, 58, and 61 mrem committed effective dose equivalent. Though the doses were low, the decontamination costs were in excess of $350,000.00. An investigation, was initiated by the U.S. Department of Energy Nevada Operations Office to analyze the events that led to the tritium contamination and recommend actions to prevent recurrence. Event and causal factor charting, Project Evaluation Tree (PET) analysis techniques, and root cause analysis, were used to evaluate management systems, causal sequences, and systems factors contributing to the tritium release.

  15. Detecting leachate plumes and groundwater pollution at Ruseifa municipal landfill utilizing VLF-EM method

    NASA Astrophysics Data System (ADS)

    Al-Tarazi, E.; Abu Rajab, J.; Al-Naqa, A.; El-Waheidi, M.

    2008-09-01

    A Very Low Frequency-Electromagnetic (VLF-EM) survey was carried out in two sites of domestic waste of old and recent landfills. The landfill structures lie on a major highly fractured limestone aquifer of shallow groundwater less than 30 m, which is considered as the main source of fresh water in Amman-Zarqa region. A total of 18 VLF-EM profiles were conducted with length ranges between 250 and 1500 m. Hydrochemical and biochemical analysis of water samples, taken from wells in the region, has also been conducted. The integrated results of previous DC resistivity method of the same study area and the outcomes of the 2-D tipper inversion of VLF-EM data proved the efficiency of this method in locating shallow and deep leachate plume with resistivity less than 20 Ω m, and enabling the mapping of anomalous bodies and their extensions down to 40 m depth. The sign of groundwater contamination was noticed in many surrounding wells resulting in the high number of fecal coliform bacteria and total coliform bacteria and the increase in inorganic parameters such as chloride (Cl). The pollution of groundwater wells in the landfill area is attributed to the leachate bodies which flow through the upper part of Wadi Es Sir (A7) or Amman-Wadi Es Sir Aquifer (B2/A7). Furthermore, several structural features were detected and the direction of local groundwater movement has been determined. The structural features have been found to have critical effects on the flowing of leachate plume towards north-northeast and west-southwest of the potable aquifer in the area.

  16. An E-M algorithm and testing strategy for multiple-locus haplotypes

    SciTech Connect

    Long, J.C.; Williams, R.C.; Urbanek, M.

    1995-03-01

    This paper gives an expectation maximization (EM) algorithm to obtain allele frequencies, haplotype frequencies, and gametic disequilibrium coefficients for multiple-locus systems. It permits high polymorphism and null alleles at all loci. This approach effectively deals with the primary estimation problems associated with such systems; that is, there is not a one-to-one correspondence between phenotypic and genotypic categories, and sample sizes tend to be much smaller than the number of phenotypic categories. The EM method provides maximum-likelihood estimates and therefore allows hypothesis tests using likelihood ratio statistics that have X{sup 2} distributions with large sample sizes. We also suggest a data resampling approach to estimate test statistic sampling distributions. The resampling approach is more computer intensive, but it is applicable to all sample sizes. A strategy to test hypotheses about aggregate groups of gametic disequilibrium coefficients is recommended. This strategy minimizes the number of necessary hypothesis tests while at the same time describing the structure of equilibrium. These methods are applied to three unlinked dinucleotide repeat loci in Navajo Indians and to three linked HLA loci in Gila River (Pima) Indians. The likelihood functions of both data sets are shown to be maximized by the EM estimates, and the testing strategy provides a useful description of the structure of gametic disequilibrium. Following these applications, a number of simulation experiments are performed to test how well the likelihood-ratio statistic distributions are approximated by X{sup 2} distributions. In most circumstances X{sup 2} grossly underestimated the probability of type I errors. However, at times they also overestimated the type 1 error probability. Accordingly, we recommend hypothesis tests that use the resampling method. 41 refs., 3 figs., 6 tabs.

  17. The ISO 14001 EMS Implementation Process and Its Implications: A Case Study of Central Japan.

    PubMed

    Mohammed

    2000-02-01

    / This study aims to investigate the ISO 14001 implementation process and its implications for regional environmental management. The region of Central Japan (known as Chubu in Japanese, which literally means center) was chosen for this case study. The study focuses on selected issues such as the: (1) trends and motives of private firms in the implementation of an ISO 14001-based environmental management system (EMS); (2) obstacles during system implementation; (3) role of the system in enhancing environmental performance within the certified organization; and (4) relation between the major stakeholders, local citizens, governments, and firms after adopting the system. To achieve these objectives, a questionnaire survey was mailed to all certified firms in the region. A 58% response was achieved overall. The results show that the main aims behind the adoption of ISO 14001 by firms in the Chubu region are to improve the environmental aspects within the enterprises and to enhance the employees' environmental awareness and capacity. The results have also shown that the ISO 14001-based EMS has had a great effect on a firm's environmental status as certified firms have claimed that natural resources such as fuel, water, and paper consumption have been more efficiently managed after adopting the system. Implementation of the system causes the firms to consider the role of the local people and the government in more effectively involving the local people in the firm's daily environmental activities. It also helps to enhance the environmental awareness among the local people. Adopting the system also promotes a better relation within the enterprises affiliated to the same group, such as more attention given by the parent firms (head offices) towards other firms working for the same group, or branches-mainly small and medium sized enterprises (SMEs)-in the field of EMS. Finally, the results show that firms give serious consideration to their final products' impacts on the

  18. An E-M algorithm and testing strategy for multiple-locus haplotypes.

    PubMed Central

    Long, J C; Williams, R C; Urbanek, M

    1995-01-01

    This paper gives an expectation maximization (EM) algorithm to obtain allele frequencies, haplotype frequencies, and gametic disequilibrium coefficients for multiple-locus systems. It permits high polymorphism and null alleles at all loci. This approach effectively deals with the primary estimation problems associated with such systems; that is, there is not a one-to-one correspondence between phenotypic and genotypic categories, and sample sizes tend to be much smaller than the number of phenotypic categories. The EM method provides maximum-likelihood estimates and therefore allows hypothesis tests using likelihood ratio statistics that have chi 2 distributions with large sample sizes. We also suggest a data resampling approach to estimate test statistic sampling distributions. The resampling approach is more computer intensive, but it is applicable to all sample sizes. A strategy to test hypotheses about aggregate groups of gametic disequilibrium coefficients is recommended. This strategy minimizes the number of necessary hypothesis tests while at the same time describing the structure of disequilibrium. These methods are applied to three unlinked dinucleotide repeat loci in Navajo Indians and to three linked HLA loci in Gila River (Pima) Indians. The likelihood functions of both data sets are shown to be maximized by the EM estimates, and the testing strategy provides a useful description of the structure of gametic disequilibrium. Following these applications, a number of simulation experiments are performed to test how well the likelihood-ratio statistic distributions are approximated by chi 2 distributions. In most circumstances the chi 2 grossly underestimated the probability of type I errors. However, at times they also overestimated the type 1 error probability. Accordingly, we recommended hypothesis tests that use the resampling method. PMID:7887436

  19. Inversion of EM38 data measured in different heights using a-priori information for stabilization

    NASA Astrophysics Data System (ADS)

    Wunderlich, Tina; Rabbel, Wolfgang

    2010-05-01

    Within the frame of the iSOIL project apparent conductivity measurements using the EM38DD (Geonics) have been conducted on different soil types. The EM38DD is mounted in different heights on a metal-free sled and pulled behind a tractor with an inline sampling distance of 20cm and a profile offset of 1m. The apparent conductivities have been inverted into real conductivities over the whole measured area. In order to improve the equation system and to avoid singular matrices 4 measurements (vertical and horizontal mode in two different heights) at one location are used to determine the conductivities of two layers and the depth of the interface between the layers. The inversion is stabilized by weighted a-priori information for both conductivities and depth and by the inclusion of neighboring points. Depth information is gained from GPR measurements over the same area that have been done in one survey together with the EM38DD measurements. The inversion results are compared to results of 1D and 2D electrical resistivity imaging using optimized and Schlumberger configurations. Principal Component Analysis is used to compare modeled and measured data and correlation coefficients between them are calculated to evaluate the reliability of the inversion. Acknowledgement: iSOIL-Interactions between soil related sciences - Linking geophysics, soil science and digital soil mapping is a Collaborative Project (Grant Agreement number 211386) co-funded by the Research DG of the European Commission within the RTD activities of the FP7 Thematic Priority Environment.

  20. Two-dimensional simulations of explosive eruptions of Kick-em Jenny and other submarine volcanos

    SciTech Connect

    Gisler, Galen R.; Weaver, R. P.; Mader, Charles L.; Gittings, M. L.

    2004-01-01

    Kick-em Jenny, in the Eastern Caribbean, is a submerged volcanic cone that has erupted a dozen or more times since its discovery in 1939. The most likely hazard posed by this volcano is to shipping in the immediate vicinity (through volcanic missiles or loss-of-buoyancy), but it is of interest to estimate upper limits on tsunamis that might be produced by a catastrophic explosive eruption. To this end, we have performed two-dimensional simulations of such an event in a geometry resembling that of Kick-em Jenny with our SAGE adaptive mesh Eulerian multifluid compressible hydrocode. We use realistic equations of state for air, water, and basalt, and follow the event from the initial explosive eruption, through the generation of a transient water cavity and the propagation of waves away from the site. We find that even for extremely catastrophic explosive eruptions, tsunamis from Kick-em Jenny are unlikely to pose significant danger to nearby islands. For comparison, we have also performed simulations of explosive eruptions at the much larger shield volcano Vailuluu in the Samoan chain, where the greater energy available can produce a more impressive wave. In general, however, we conclude that explosive eruptions do not couple well to water waves. The waves that are produced from such events are turbulent and highly dissipative, and don't propagate well. This is consistent with what we have found previously in simulations of asteroid-impact generated tsunamis. Non-explosive events, however, such as landslides or gas hydrate releases, do couple well to waves, and our simulations of tsunamis generated by subaerial and sub-aqueous landslides demonstrate this.